Sample records for standard display function

  1. Regularity Results for a Class of Functionals with Non-Standard Growth

    NASA Astrophysics Data System (ADS)

    Acerbi, Emilio; Mingione, Giuseppe

    We consider the integral functional under non-standard growth assumptions that we call p(x) type: namely, we assume that a relevant model case being the functional Under sharp assumptions on the continuous function p(x)>1 we prove regularity of minimizers. Energies exhibiting this growth appear in several models from mathematical physics.

  2. Hard copies for digital medical images: an overview

    NASA Astrophysics Data System (ADS)

    Blume, Hartwig R.; Muka, Edward

    1995-04-01

    This paper is a condensed version of an invited overview on the technology of film hard-copies used in radiology. Because the overview was given to an essentially nonmedical audience, the reliance on film hard-copies in radiology is outlined in greater detail. The overview is concerned with laser image recorders generating monochrome prints on silver-halide films. The basic components of laser image recorders are sketched. The paper concentrates on the physical parameters - characteristic function, dynamic range, digitization resolution, modulation transfer function, and noise power spectrum - which define image quality and information transfer capability of the printed image. A preliminary approach is presented to compare the printed image quality with noise in the acquired image as well as with the noise of state-of- the-art cathode-ray-tube display systems. High-performance laser-image- recorder/silver-halide-film/light-box systems are well capable of reproducing acquired radiologic information. Most recently development was begun toward a display function standard for soft-copy display systems to facilitate similarity of image presentation between different soft-copy displays as well as between soft- and hard-copy displays. The standard display function is based on perceptional linearization. The standard is briefly reviewed to encourage the printer industry to adopt it, too.

  3. Pilot stereotypes for navigation symbols on electronic displays

    DOT National Transportation Integrated Search

    2006-09-20

    There is currently no common symbology standard for the : electronic display of navigation information. The wide : range of display technologies and the different functions : these displays support make it difficult to design symbols : that are easil...

  4. A review of contemporary methods for the presentation of scientific uncertainty.

    PubMed

    Makinson, K A; Hamby, D M; Edwards, J A

    2012-12-01

    Graphic methods for displaying uncertainty are often the most concise and informative way to communicate abstract concepts. Presentation methods currently in use for the display and interpretation of scientific uncertainty are reviewed. Numerous subjective and objective uncertainty display methods are presented, including qualitative assessments, node and arrow diagrams, standard statistical methods, box-and-whisker plots,robustness and opportunity functions, contribution indexes, probability density functions, cumulative distribution functions, and graphical likelihood functions.

  5. Designing and evaluating symbols for electronic displays of navigation information : symbol stereotypes and symbol-feature rules

    DOT National Transportation Integrated Search

    2005-09-30

    There is currently no common symbology standard for the electronic display of navigation information. The wide range of display technology and the different functions these displays support makes it difficult to design symbols that are easily recogni...

  6. A new display stream compression standard under development in VESA

    NASA Astrophysics Data System (ADS)

    Jacobson, Natan; Thirumalai, Vijayaraghavan; Joshi, Rajan; Goel, James

    2017-09-01

    The Advanced Display Stream Compression (ADSC) codec project is in development in response to a call for technologies from the Video Electronics Standards Association (VESA). This codec targets visually lossless compression of display streams at a high compression rate (typically 6 bits/pixel) for mobile/VR/HDR applications. Functionality of the ADSC codec is described in this paper, and subjective trials results are provided using the ISO 29170-2 testing protocol.

  7. Features and limitations of mobile tablet devices for viewing radiological images.

    PubMed

    Grunert, J H

    2015-03-01

    Mobile radiological image display systems are becoming increasingly common, necessitating a comparison of the features of these systems, specifically the operating system employed, connection to stationary PACS, data security and rang of image display and image analysis functions. In the fall of 2013, a total of 17 PACS suppliers were surveyed regarding the technical features of 18 mobile radiological image display systems using a standardized questionnaire. The study also examined to what extent the technical specifications of the mobile image display systems satisfy the provisions of the Germany Medical Devices Act as well as the provisions of the German X-ray ordinance (RöV). There are clear differences in terms of how the mobile systems connected to the stationary PACS. Web-based solutions allow the mobile image display systems to function independently of their operating systems. The examined systems differed very little in terms of image display and image analysis functions. Mobile image display systems complement stationary PACS and can be used to view images. The impacts of the new quality assurance guidelines (QS-RL) as well as the upcoming new standard DIN 6868 - 157 on the acceptance testing of mobile image display units for the purpose of image evaluation are discussed. © Georg Thieme Verlag KG Stuttgart · New York.

  8. 25 CFR 547.9 - What are the minimum technical standards for Class II gaming system accounting functions?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... OF CLASS II GAMES § 547.9 What are the minimum technical standards for Class II gaming system... digits to accommodate the design of the game. (3) Accounting data displayed to the player may be... audit, configuration, recall and test modes; or (ii) Temporarily, during entertaining displays of game...

  9. 25 CFR 547.9 - What are the minimum technical standards for Class II gaming system accounting functions?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... OF CLASS II GAMES § 547.9 What are the minimum technical standards for Class II gaming system... digits to accommodate the design of the game. (3) Accounting data displayed to the player may be... audit, configuration, recall and test modes; or (ii) Temporarily, during entertaining displays of game...

  10. 25 CFR 547.9 - What are the minimum technical standards for Class II gaming system accounting functions?

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... OF CLASS II GAMES § 547.9 What are the minimum technical standards for Class II gaming system... digits to accommodate the design of the game. (3) Accounting data displayed to the player may be... audit, configuration, recall and test modes; or (ii) Temporarily, during entertaining displays of game...

  11. New DICOM extensions for softcopy and hardcopy display consistency.

    PubMed

    Eichelberg, M; Riesmeier, J; Kleber, K; Grönemeyer, D H; Oosterwijk, H; Jensch, P

    2000-01-01

    The DICOM standard defines in detail how medical images can be communicated. However, the rules on how to interpret the parameters contained in a DICOM image which deal with the image presentation were either lacking or not well defined. As a result, the same image frequently looks different when displayed on different workstations or printed on a film from various printers. Three new DICOM extensions attempt to close this gap by defining a comprehensive model for the display of images on softcopy and hardcopy devices: Grayscale Standard Display Function, Grayscale Softcopy Presentation State and Presentation Look Up Table.

  12. Unmanned Aircraft Systems (UAS) Integration in the National Airspace System (NAS) Project: Detect and Avoid Display Evaluations in Support of SC-228 Minimum Operational Performance Standards Development

    NASA Technical Reports Server (NTRS)

    Fern, Lisa Carolynn

    2017-01-01

    The primary activity for the UAS-NAS Human Systems Integration (HSI) sub-project in Phase 1 was support of RTCA Special Committee 228 Minimum Operational Performance Standards (MOPS). We provide data on the effect of various Detect and Avoid (DAA) display features with respect to pilot performance of the remain well clear function in order to determine the minimum requirements for DAA displays.

  13. The Formal Specification of a Visual display Device: Design and Implementation.

    DTIC Science & Technology

    1985-06-01

    The use of these data structures with their defined operations, give the programmer a very powerful instructions set. Like the DPU code generator in...which any AM hosted machine could faithfully display. 27 In- general , most applications have no need to create images from a data structure representing...formation of standard functional interfaces to these resources. OS’s generally do not provide a functional interface to either the processor or the display2

  14. The effect of time in use on the display performance of the iPad.

    PubMed

    Caffery, Liam J; Manthey, Kenneth L; Sim, Lawrence H

    2016-07-01

    The aim of this study was to evaluate changes to the luminance, luminance uniformity and conformance to the digital imaging and communication in medicine greyscale standard display function (GSDF) as a function of time in use for the iPad. Luminance measurements of the American Association of Physicists in Medicine (AAPM) Group 18 task group (TG18) luminance uniformity and luminance test patterns (TG18-UNL and TG18-LN8) were performed using a calibrated near-range luminance meter. Nine sets of measurements were taken, where the time in use of the iPad ranged from 0 to 2500 h. The maximum luminance (Lmax) of the display decreased (367-338 cdm(-2)) as a function of time. The minimum luminance remained constant. The maximum non-uniformity coefficient was 11%. Luminance uniformity decreased slightly as a function of time in use. The conformance of the iPad deviated from the GSDF curve at commencement of use. Deviation did not increase as a function of time in use. This study has demonstrated that the iPad display exhibits luminance degradation typical of liquid crystal displays. The Lmax of the iPad fell below the American College of Radiology-AAPM-Society of Imaging Informatics in Medicine recommendations for primary displays (>350 cdm(-2)) at approximately 1000 h in use. The Lmax recommendation for secondary displays (>250 cdm(-2)) was exceeded during the entire study. The maximum non-uniformity coefficient did not exceed the recommendations for either primary or secondary displays. The deviation from the GSDF exceeded the recommendations of the TG18 for use as either a primary or secondary display. The brightness, uniformity and contrast response are reasonably stable over the useful lifetime of the device; however, the device fails to meet the contrast response standard for either a primary or secondary display.

  15. Polychromatic plots: graphical display of multidimensional data.

    PubMed

    Roederer, Mario; Moody, M Anthony

    2008-09-01

    Limitations of graphical displays as well as human perception make the presentation and analysis of multidimensional data challenging. Graphical display of information on paper or by current projectors is perforce limited to two dimensions; the encoding of information from other dimensions must be overloaded into the two physical dimensions. A number of alternative means of encoding this information have been implemented, such as offsetting data points at an angle (e.g., three-dimensional projections onto a two-dimensional surface) or generating derived parameters that are combinations of other variables (e.g., principal components). Here, we explore the use of color to encode additional dimensions of data. PolyChromatic Plots are standard dot plots, where the color of each event is defined by the values of one, two, or three of the measurements for that event. The measurements for these parameters are mapped onto an intensity value for each primary color (red, green, or blue) based on different functions. In addition, differential weighting of the priority with which overlapping events are displayed can be defined by these same measurements. PolyChromatic Plots can encode up to five independent dimensions of data in a single display. By altering the color mapping function and the priority function, very different displays that highlight or de-emphasize populations of events can be generated. As for standard black-and-white dot plots, frequency information can be significantly biased by this display; care must be taken to ensure appropriate interpretation of the displays. PolyChromatic Plots are a powerful display type that enables rapid data exploration. By virtue of encoding as many as five dimensions of data independently, an enormous amount of information can be gleaned from the displays. In many ways, the display performs somewhat like an unsupervised cluster algorithm, by highlighting events of similar distributions in multivariate space.

  16. Assessment of Innovative Emergency Department Information Displays in a Clinical Simulation Center

    PubMed Central

    McGeorge, Nicolette; Hegde, Sudeep; Berg, Rebecca L.; Guarrera-Schick, Theresa K.; LaVergne, David T.; Casucci, Sabrina N.; Hettinger, A. Zachary; Clark, Lindsey N.; Lin, Li; Fairbanks, Rollin J.; Benda, Natalie C.; Sun, Longsheng; Wears, Robert L.; Perry, Shawna; Bisantz, Ann

    2016-01-01

    The objective of this work was to assess the functional utility of new display concepts for an emergency department information system created using cognitive systems engineering methods, by comparing them to similar displays currently in use. The display concepts were compared to standard displays in a clinical simulation study during which nurse-physician teams performed simulated emergency department tasks. Questionnaires were used to assess the cognitive support provided by the displays, participants’ level of situation awareness, and participants’ workload during the simulated tasks. Participants rated the new displays significantly higher than the control displays in terms of cognitive support. There was no significant difference in workload scores between the display conditions. There was no main effect of display type on situation awareness, but there was a significant interaction; participants using the new displays showed improved situation awareness from the middle to the end of the session. This study demonstrates that cognitive systems engineering methods can be used to create innovative displays that better support emergency medicine tasks, without increasing workload, compared to more standard displays. These methods provide a means to develop emergency department information systems—and more broadly, health information technology—that better support the cognitive needs of healthcare providers. PMID:27974881

  17. LMDS Lightweight Modular Display System.

    DTIC Science & Technology

    1982-02-16

    based on standard functions. This means that the cost to produce a particular display function can be met in the most economical fashion and at the same...not mean that the NTDS interface would be eliminated. What is anticipated is the use of ETHERNET at a low level of system interface, ie internal to...GENERATOR dSYMBOL GEN eCOMMUNICATION 3-2 The architecture of the unit’s (fig 3-4) input circuitry is based on a video table look-up ROM. The function

  18. Software Verification of Orion Cockpit Displays

    NASA Technical Reports Server (NTRS)

    Biswas, M. A. Rafe; Garcia, Samuel; Prado, Matthew; Hossain, Sadad; Souris, Matthew; Morin, Lee

    2017-01-01

    NASA's latest spacecraft Orion is in the development process of taking humans deeper into space. Orion is equipped with three main displays to monitor and control the spacecraft. To ensure the software behind the glass displays operates without faults, rigorous testing is needed. To conduct such testing, the Rapid Prototyping Lab at NASA's Johnson Space Center along with the University of Texas at Tyler employed a software verification tool, EggPlant Functional by TestPlant. It is an image based test automation tool that allows users to create scripts to verify the functionality within a program. A set of edge key framework and Common EggPlant Functions were developed to enable creation of scripts in an efficient fashion. This framework standardized the way to code and to simulate user inputs in the verification process. Moreover, the Common EggPlant Functions can be used repeatedly in verification of different displays.

  19. Grayscale standard display function on LCD color monitors

    NASA Astrophysics Data System (ADS)

    De Monte, Denis; Casale, Carlo; Albani, Luigi; Bonfiglio, Silvio

    2007-03-01

    Currently, as a rule, digital medical systems use monochromatic Liquid Crystal Display (LCD) monitors to ensure an accurate reproduction of the Grayscale Standard Display Function (GSDF) as specified in the Digital Imaging and Communications in Medicine (DICOM) Standard. As a drawback, special panels need to be utilized in digital medical systems, while it would be preferable to use regular color panels, which are manufactured on a wide scale and are thus available at by far lower prices. The method proposed introduces a temporal color dithering technique to accurately reproduce the GSDF on color monitors without losing monitor resolution. By exploiting the characteristics of the Human Visual System (HVS) the technique ensures that a satisfactory grayscale reproduction is achieved minimizing perceivable flickering and undesired color artifacts. The algorithm has been implemented in the monitor using a low-cost Field Programmable Gate Array (FPGA). Quantitative evaluations of luminance response on a 3 Mega-pixel color monitor have shown that the compliance with the GSDF can be achieved with the accuracy level required by medical applications. At the same time the measured color deviation is below the threshold perceivable by the human eye.

  20. A New Wrist Clinical Evaluation Score.

    PubMed

    Herzberg, Guillaume; Burnier, Marion; Nakamura, Toshiyasu

    2018-04-01

    Background  The number of available wrist scoring systems is limited; some of them do not include forearm rotation criteria. Purpose  To describe a new electronic wrist clinical score and to present a new patient's generated wrist evaluation criterion, the subjective wrist value (SWV). Materials and Methods  A new electronic wrist clinical score, the Lyon wrist score (LWS) including wrist VAS pain and function, active range of motion and strength was built into an excel file. VAS flexion-extension pain and function were evaluated independently from pronation-supination pain and function. A new patient's generated wrist evaluation criterion, SWV was described. Results  The LWS is available in two versions, standard and full (the latter including forearm rotation strength). Both standard and full LWS are displayed into an automatically generated diamond-shaped graph providing a comprehensive visual display of the clinical status of most osteoarticular wrist disorders. The graph also includes SWV. The LWS, combined with SWV into a graph that may be directly exported to a PowerPoint presentation, provide a new practical and comprehensive tool for following/comparing wrist osteoarticular clinical status/outcomes. Both standard and full LWS charts are available in colored versions on a related website for free download. Conclusion  A comprehensive updated electronic display of osteoarticular wrist clinical status including forearm rotation criteria is provided and displayed into a graph which may be exported as such into a PowerPoint presentation for clinical analysis/comparisons. Level of Evidence  Level II.

  1. JAVA Stereo Display Toolkit

    NASA Technical Reports Server (NTRS)

    Edmonds, Karina

    2008-01-01

    This toolkit provides a common interface for displaying graphical user interface (GUI) components in stereo using either specialized stereo display hardware (e.g., liquid crystal shutter or polarized glasses) or anaglyph display (red/blue glasses) on standard workstation displays. An application using this toolkit will work without modification in either environment, allowing stereo software to reach a wider audience without sacrificing high-quality display on dedicated hardware. The toolkit is written in Java for use with the Swing GUI Toolkit and has cross-platform compatibility. It hooks into the graphics system, allowing any standard Swing component to be displayed in stereo. It uses the OpenGL graphics library to control the stereo hardware and to perform the rendering. It also supports anaglyph and special stereo hardware using the same API (application-program interface), and has the ability to simulate color stereo in anaglyph mode by combining the red band of the left image with the green/blue bands of the right image. This is a low-level toolkit that accomplishes simply the display of components (including the JadeDisplay image display component). It does not include higher-level functions such as disparity adjustment, 3D cursor, or overlays all of which can be built using this toolkit.

  2. Visualizing the anatomical-functional correlation of the human brain

    NASA Astrophysics Data System (ADS)

    Chang, YuKuang; Rockwood, Alyn P.; Reiman, Eric M.

    1995-04-01

    Three-dimensional tomographic images obtained from different modalities or from the same modality at different times provide complementary information. For example, while PET shows brain function, images from MRI identify anatomical structures. In this paper, we investigate the problem of displaying available information about structures and function together. Several steps are described to achieve our goal. These include segmentation of the data, registration, resampling, and display. Segmentation is used to identify brain tissue from surrounding tissues, especially in the MRI data. Registration aligns the different modalities as closely as possible. Resampling arises from the registration since two data sets do not usually correspond and the rendering method is most easily achieved if the data correspond to the same grid used in display. We combine several techniques to display the data. MRI data is reconstructed from 2D slices into 3D structures from which isosurfaces are extracted and represented by approximating polygonalizations. These are then displayed using standard graphics pipelines including shaded and transparent images. PET data measures the qualitative rates of cerebral glucose utilization or oxygen consumption. PET image is best displayed as a volume of luminous particles. The combination of both display methods allows the viewer to compare the functional information contained in the PET data with the anatomically more precise MRI data.

  3. Expanding Dimensionality in Cinema Color: Impacting Observer Metamerism through Multiprimary Display

    NASA Astrophysics Data System (ADS)

    Long, David L.

    Television and cinema display are both trending towards greater ranges and saturation of reproduced colors made possible by near-monochromatic RGB illumination technologies. Through current broadcast and digital cinema standards work, system designs employing laser light sources, narrow-band LED, quantum dots and others are being actively endorsed in promotion of Wide Color Gamut (WCG). Despite artistic benefits brought to creative content producers, spectrally selective excitations of naturally different human color response functions exacerbate variability of observer experience. An exaggerated variation in color-sensing is explicitly counter to the exhaustive controls and calibrations employed in modern motion picture pipelines. Further, singular standard observer summaries of human color vision such as found in the CIE's 1931 and 1964 color matching functions and used extensively in motion picture color management are deficient in recognizing expected human vision variability. Many researchers have confirmed the magnitude of observer metamerism in color matching in both uniform colors and imagery but few have shown explicit color management with an aim of minimized difference in observer perception variability. This research shows that not only can observer metamerism influences be quantitatively predicted and confirmed psychophysically but that intentionally engineered multiprimary displays employing more than three primaries can offer increased color gamut with drastically improved consistency of experience. To this end, a seven-channel prototype display has been constructed based on observer metamerism models and color difference indices derived from the latest color vision demographic research. This display has been further proven in forced-choice paired comparison tests to deliver superior color matching to reference stimuli versus both contemporary standard RGB cinema projection and recently ratified standard laser projection across a large population of color-normal observers.

  4. User's manual for flight Simulator Display System (FSDS)

    NASA Technical Reports Server (NTRS)

    Egerdahl, C. C.

    1979-01-01

    The capabilities of the flight simulator display system (FSDS) are described. FSDS is a color raster scan display generator designed to meet the special needs of Flight Simulation Laboratories. The FSDS can update (revise) the images it generates every 16.6 mS, with limited support from a host processor. This corresponds to the standard TV vertical rate of 60 Hertz, and allows the system to carry out display functions in a time critical environment. Rotation of a complex image in the television raster with minimal hardware is possible with the system.

  5. WE-D-9A-06: Open Source Monitor Calibration and Quality Control Software for Enterprise Display Management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bevins, N; Vanderhoek, M; Lang, S

    2014-06-15

    Purpose: Medical display monitor calibration and quality control present challenges to medical physicists. The purpose of this work is to demonstrate and share experiences with an open source package that allows for both initial monitor setup and routine performance evaluation. Methods: A software package, pacsDisplay, has been developed over the last decade to aid in the calibration of all monitors within the radiology group in our health system. The software is used to calibrate monitors to follow the DICOM Grayscale Standard Display Function (GSDF) via lookup tables installed on the workstation. Additional functionality facilitates periodic evaluations of both primary andmore » secondary medical monitors to ensure satisfactory performance. This software is installed on all radiology workstations, and can also be run as a stand-alone tool from a USB disk. Recently, a database has been developed to store and centralize the monitor performance data and to provide long-term trends for compliance with internal standards and various accrediting organizations. Results: Implementation and utilization of pacsDisplay has resulted in improved monitor performance across the health system. Monitor testing is now performed at regular intervals and the software is being used across multiple imaging modalities. Monitor performance characteristics such as maximum and minimum luminance, ambient luminance and illuminance, color tracking, and GSDF conformity are loaded into a centralized database for system performance comparisons. Compliance reports for organizations such as MQSA, ACR, and TJC are generated automatically and stored in the same database. Conclusion: An open source software solution has simplified and improved the standardization of displays within our health system. This work serves as an example method for calibrating and testing monitors within an enterprise health system.« less

  6. Determination of washout performance of various monochrome displays under simulated flight ambient and solar lighting conditions

    NASA Technical Reports Server (NTRS)

    Batson, Vernon M.; Robertson, James B.; Parrish, Russell V.

    1990-01-01

    The aircraft cockpit ambient lighting simulation system (ACALSS) has been developed to study display readability and associated pilot/vehicle performance effects in a part-task simulator cockpit. In the study reported here, the ACALSS was used to determine the illumination levels at which subjects lose the ability to maintain aircraft states when using three display technologies as display media for primary flight displays: a standard monochrome EL (electroluminescent) flat-panel, a laboratory-class monochrome CRT, and an enhanced-brightness EL flat-panel. The multivariate statistical technique of modified profile analysis was used to test for performance differences between display devices as functions of illumination levels. The standard monochrome EL flat-panel display began to washout after the 2500 foot-candle level of illumination. The monochrome CRT began to washout after the 5500 foot-candle level of illumination. No performance decrements by increased illumination up to the 12,000 foot-candle level were found for the enhanced-brightness EL flat-panel display. What was not anticipated was that half the subjects would subjectively prefer the CRT over the enhanced-brightness EL, even though their performance errors would have indicated the opposite.

  7. Advanced Transport Operating System (ATOPS) color displays software description: MicroVAX system

    NASA Technical Reports Server (NTRS)

    Slominski, Christopher J.; Plyler, Valerie E.; Dickson, Richard W.

    1992-01-01

    This document describes the software created for the Display MicroVAX computer used for the Advanced Transport Operating Systems (ATOPS) project on the Transport Systems Research Vehicle (TSRV). The software delivery of February 27, 1991, known as the 'baseline display system', is the one described in this document. Throughout this publication, module descriptions are presented in a standardized format which contains module purpose, calling sequence, detailed description, and global references. The global references section includes subroutines, functions, and common variables referenced by a particular module. The system described supports the Research Flight Deck (RFD) of the TSRV. The RFD contains eight Cathode Ray Tubes (CRTs) which depict a Primary Flight Display, Navigation Display, System Warning Display, Takeoff Performance Monitoring System Display, and Engine Display.

  8. Assembling Appliances Standards from a Basket of Functions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Siderious, Hans-Paul; Meier, Alan

    2014-08-11

    Rapid innovation in product design challenges the current methodology for setting standards and labels, especially for electronics, software and networking. Major problems include defining the product, measuring its energy consumption, and choosing the appropriate metric and level for the standard. Most governments have tried to solve these problems by defining ever more specific product subcategories, along with their corresponding test methods and metrics. An alternative approach would treat each energy-using product as something that delivers a basket of functions. Then separate standards would be constructed for the individual functions that can be defined, tested, and evaluated. Case studies of thermostats,more » displays and network equipment are presented to illustrate the problems with the classical approach for setting standards and indicate the merits and drawbacks of the alternative. The functional approach appears best suited to products whose primary purpose is processing information and that have multiple functions.« less

  9. An Evaluation of Detect and Avoid (DAA) Displays for Unmanned Aircraft Systems: The Effect of Information Level and Display Location on Pilot Performance

    NASA Technical Reports Server (NTRS)

    Fern, Lisa; Rorie, R. Conrad; Pack, Jessica S.; Shively, R. Jay; Draper, Mark H.

    2015-01-01

    A consortium of government, industry and academia is currently working to establish minimum operational performance standards for Detect and Avoid (DAA) and Control and Communications (C2) systems in order to enable broader integration of Unmanned Aircraft Systems (UAS) into the National Airspace System (NAS). One subset of these performance standards will need to address the DAA display requirements that support an acceptable level of pilot performance. From a pilot's perspective, the DAA task is the maintenance of self separation and collision avoidance from other aircraft, utilizing the available information and controls within the Ground Control Station (GCS), including the DAA display. The pilot-in-the-loop DAA task requires the pilot to carry out three major functions: 1) detect a potential threat, 2) determine an appropriate resolution maneuver, and 3) execute that resolution maneuver via the GCS control and navigation interface(s). The purpose of the present study was to examine two main questions with respect to DAA display considerations that could impact pilots' ability to maintain well clear from other aircraft. First, what is the effect of a minimum (or basic) information display compared to an advanced information display on pilot performance? Second, what is the effect of display location on UAS pilot performance? Two levels of information level (basic, advanced) were compared across two levels of display location (standalone, integrated), for a total of four displays. The authors propose an eight-stage pilot-DAA interaction timeline from which several pilot response time metrics can be extracted. These metrics were compared across the four display conditions. The results indicate that the advanced displays had faster overall response times compared to the basic displays, however, there were no significant differences between the standalone and integrated displays. Implications of the findings on understanding pilot performance on the DAA task, the development of DAA display performance standards, as well as the need for future research are discussed.

  10. SU-E-P-29: Testing Display Monitors for GSDF Compliance - a Practical Approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gauntt, D

    2015-06-15

    Purpose: To develop a simple technique for testing display monitors for compliance with the DICOM Grayscale Standard Display Function (GSDF), in accordance with the recommendations of AAPM Task Group 18. Methods: We have developed a spreadsheet that can be used to compare both the luminance response and contrast response of a display to the GSDF, using luminance measurements of the SMPTE test pattern. The contrast response compares the slope of the GSDF j-index as a function of pixel value to that of the GSDF function, and should lie within the range 0.85 to 1.15. Results: We present the results ofmore » measurements both of primary diagnostic displays and of ultrasound and acquisition workstations, all at a tertiary care hospital. The Barco displays in the radiographic reading rooms are GSDF compliant or nearly so, while those in the ultrasound reading rooms and at the acquisition workstations generally show significantly higher contrast at low luminance levels than they would if GSDF compliant, and lower contrast at high luminance levels. Conclusion: The spreadsheet that we developed allows a simple comparison of measured display contrast response to the GSDF. Although we used the SMPTE pattern, the same technique could be used with other grayscale patterns, such as TG18-QC and TG18-PQC.« less

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kimpe, T; Marchessoux, C; Rostang, J

    Purpose: Use of color images in medical imaging has increased significantly the last few years. As of today there is no agreed standard on how color information needs to be visualized on medical color displays, resulting into large variability of color appearance and it making consistency and quality assurance a challenge. This paper presents a proposal for an extension of DICOM GSDF towards color. Methods: Visualization needs for several color modalities (multimodality imaging, nuclear medicine, digital pathology, quantitative imaging applications…) have been studied. On this basis a proposal was made for desired color behavior of color medical display systems andmore » its behavior and effect on color medical images was analyzed. Results: Several medical color modalities could benefit from perceptually linear color visualization for similar reasons as why GSDF was put in place for greyscale medical images. An extension of the GSDF (Greyscale Standard Display Function) to color is proposed: CSDF (color standard display function). CSDF is based on deltaE2000 and offers a perceptually linear color behavior. CSDF uses GSDF as its neutral grey behavior. A comparison between sRGB/GSDF and CSDF confirms that CSDF significantly improves perceptual color linearity. Furthermore, results also indicate that because of the improved perceptual linearity, CSDF has the potential to increase perceived contrast of clinically relevant color features. Conclusion: There is a need for an extension of GSDF towards color visualization in order to guarantee consistency and quality. A first proposal (CSDF) for such extension has been made. Behavior of a CSDF calibrated display has been characterized and compared with sRGB/GSDF behavior. First results indicate that CSDF could have a positive influence on perceived contrast of clinically relevant color features and could offer benefits for quantitative imaging applications. Authors are employees of Barco Healthcare.« less

  12. Lens ray diagrams with a spreadsheet

    NASA Astrophysics Data System (ADS)

    González, Manuel I.

    2018-05-01

    Physicists create spreadsheets customarily to carry out numerical calculations and to display their results in a meaningful, nice-looking way. Spreadsheets can also be used to display a vivid geometrical model of a physical system. This statement is illustrated with an example taken from geometrical optics: images formed by a thin lens. A careful mixture of standard Excel functions allows to display a realistic automated ray diagram. The suggested spreadsheet is intended as an auxiliary didactic tool for instructors who wish to teach their students to create their own ray diagrams.

  13. Advanced Transport Operating System (ATOPS) control display unit software description

    NASA Technical Reports Server (NTRS)

    Slominski, Christopher J.; Parks, Mark A.; Debure, Kelly R.; Heaphy, William J.

    1992-01-01

    The software created for the Control Display Units (CDUs), used for the Advanced Transport Operating Systems (ATOPS) project, on the Transport Systems Research Vehicle (TSRV) is described. Module descriptions are presented in a standardized format which contains module purpose, calling sequence, a detailed description, and global references. The global reference section includes subroutines, functions, and common variables referenced by a particular module. The CDUs, one for the pilot and one for the copilot, are used for flight management purposes. Operations performed with the CDU affects the aircraft's guidance, navigation, and display software.

  14. Progressing From Initially Ambiguous Functional Analyses: Three Case Examples

    PubMed Central

    Tiger, Jeffrey H.; Fisher, Wayne W.; Toussaint, Karen A.; Kodak, Tiffany

    2009-01-01

    Most often functional analyses are initiated using a standard set of test conditions, similar to those described by Iwata, Dorsey, Slifer, Bauman, and Richman (1982/1994). These test conditions involve the careful manipulation of motivating operations, discriminative stimuli, and reinforcement contingencies to determine the events related to the occurrence and maintenance of problem behavior. Some individuals display problem behavior that is occasioned and reinforced by idiosyncratic or otherwise unique combinations of environmental antecedents and consequences of behavior, which are unlikely to be detected using these standard assessment conditions. For these individuals, modifications to the standard test conditions or the inclusion of novel test conditions may result in clearer assessment outcomes. The current study provides three case examples of individuals whose functional analyses were initially undifferentiated; however, modifications to the standard conditions resulted in the identification of behavioral functions and the implementation of effective function-based treatments. PMID:19233611

  15. 25 CFR 542.7 - What are the minimum internal control standards for bingo?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... acceptable. (b) Game play standards. (1) The functions of seller and payout verifier shall be segregated... selected in the bingo game. (5) Each ball shall be shown to a camera immediately before it is called so that it is individually displayed to all customers. For speed bingo games not verified by camera...

  16. 25 CFR 542.7 - What are the minimum internal control standards for bingo?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...) Game play standards. (1) The functions of seller and payout verifier shall be segregated. Employees who... selected in the bingo game. (5) Each ball shall be shown to a camera immediately before it is called so that it is individually displayed to all customers. For speed bingo games not verified by camera...

  17. Planning Orbiter Flights

    NASA Technical Reports Server (NTRS)

    Harris, H. M.; Bergam, M. J.; Kim, S. L.; Smith, E. A.

    1987-01-01

    Shuttle Mission Design and Operations Software (SMDOS) assists in design and operation of missions involving spacecraft in low orbits around Earth by providing orbital and graphics information. SMDOS performs following five functions: display two world and two polar maps or any user-defined window 5 degrees high in latitude by 5 degrees wide in longitude in one of eight standard projections; designate Earth sites by points or polygon shapes; plot spacecraft ground track with 1-min demarcation lines; display, by means of different colors, availability of Tracking and Data Relay Satellite to Shuttle; and calculate available times and orbits to view particular site, and corresponding look angles. SMDOS written in Laboratory Micro-systems FORTH (1979 standard)

  18. Comparison of genetic algorithms with conjugate gradient methods

    NASA Technical Reports Server (NTRS)

    Bosworth, J. L.; Foo, N. Y.; Zeigler, B. P.

    1972-01-01

    Genetic algorithms for mathematical function optimization are modeled on search strategies employed in natural adaptation. Comparisons of genetic algorithms with conjugate gradient methods, which were made on an IBM 1800 digital computer, show that genetic algorithms display superior performance over gradient methods for functions which are poorly behaved mathematically, for multimodal functions, and for functions obscured by additive random noise. Genetic methods offer performance comparable to gradient methods for many of the standard functions.

  19. Current Status Of Ergonomic Standards

    NASA Astrophysics Data System (ADS)

    Lynch, Gene

    1984-05-01

    The last five years have seen the development and adoption of new kinds of standards for the display industry. This standardization activity deals with the complex human computer interface. Here the concerns involve health, safety, productivity, and operator well-being. The standards attempt to specify the "proper" use of visual display units. There is a wide range of implications for the display industry - as manufacturers of displays, as employers, and as users of visual display units. In this paper we examine the development of these standards, their impact on the display industry and implications for the future.

  20. Calibration of medium-resolution monochrome cathode ray tube displays for the purpose of board examinations.

    PubMed

    Evanoff, M G; Roehrig, H; Giffords, R S; Capp, M P; Rovinelli, R J; Hartmann, W H; Merritt, C

    2001-06-01

    This report discusses calibration and set-up procedures for medium-resolution monochrome cathode ray tubes (CRTs) taken in preparation of the oral portion of the board examination of the American Board of Radiology (ABR). The board examinations took place in more than 100 rooms of a hotel. There was one display-station (a computer and the associated CRT display) in each of the hotel rooms used for the examinations. The examinations covered the radiologic specialties cardiopulmonary, musculoskeletal, gastrointestinal, vascular, pediatric, and genitourinary. The software used for set-up and calibration was the VeriLUM 4.0 package from Image Smiths in Germantown, MD. The set-up included setting minimum luminance and maximum luminance, as well as positioning of the CRT in each examination room with respect to reflections of roomlights. The calibration for the grey scale rendition was done meeting the Digital Imaging and communication in Medicine (DICOM) 14 Standard Display Function. We describe these procedures, and present the calibration data in. tables and graphs, listing initial values of minimum luminance, maximum luminance, and grey scale rendition (DICOM 14 standard display function). Changes of these parameters over the duration of the examination were observed and recorded on 11 monitors in a particular room. These changes strongly suggest that all calibrated CRTs be monitored over the duration of the examination. In addition, other CRT performance data affecting image quality such as spatial resolution should be included in set-up and image quality-control procedures.

  1. GENASIS Basics: Object-oriented utilitarian functionality for large-scale physics simulations (Version 2)

    NASA Astrophysics Data System (ADS)

    Cardall, Christian Y.; Budiardja, Reuben D.

    2017-05-01

    GenASiS Basics provides Fortran 2003 classes furnishing extensible object-oriented utilitarian functionality for large-scale physics simulations on distributed memory supercomputers. This functionality includes physical units and constants; display to the screen or standard output device; message passing; I/O to disk; and runtime parameter management and usage statistics. This revision -Version 2 of Basics - makes mostly minor additions to functionality and includes some simplifying name changes.

  2. Standardization of databases for AMDB taxi routing functions

    NASA Astrophysics Data System (ADS)

    Pschierer, C.; Sindlinger, A.; Schiefele, J.

    2010-04-01

    Input, management, and display of taxi routes on airport moving map displays (AMM) have been covered in various studies in the past. The demonstrated applications are typically based on Aerodrome Mapping Databases (AMDB). Taxi routing functions require specific enhancements, typically in the form of a graph network with nodes and edges modeling all connectivities within an airport, which are not supported by the current AMDB standards. Therefore, the data schemas and data content have been defined specifically for the purpose and test scenarios of these studies. A standardization of the data format for taxi routing information is a prerequisite for turning taxi routing functions into production. The joint RTCA/EUROCAE special committee SC-217, responsible for updating and enhancing the AMDB standards DO-272 [1] and DO-291 [2], is currently in the process of studying different alternatives and defining reasonable formats. Requirements for taxi routing data are primarily driven by depiction concepts for assigned and cleared taxi routes, but also by database size and the economic feasibility. Studied concepts are similar to the ones described in the GDF (geographic data files) specification [3], which is used in most car navigation systems today. They include - A highly aggregated graph network of complex features - A modestly aggregated graph network of simple features - A non-explicit topology of plain AMDB taxi guidance line elements This paper introduces the different concepts and their advantages and disadvantages.

  3. 25 CFR 547.9 - What are the minimum technical standards for Class II gaming system accounting functions?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    .... (2) Credit balances must have sufficient digits to accommodate the design of the game. (3) Accounting..., during entertaining displays of game results. (2) Progressive prizes may be added to the player's credit...

  4. 25 CFR 547.9 - What are the minimum technical standards for Class II gaming system accounting functions?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    .... (2) Credit balances must have sufficient digits to accommodate the design of the game. (3) Accounting..., during entertaining displays of game results. (2) Progressive prizes may be added to the player's credit...

  5. Adaptation of Control Center Software to Commerical Real-Time Display Applications

    NASA Technical Reports Server (NTRS)

    Collier, Mark D.

    1994-01-01

    NASA-Marshall Space Flight Center (MSFC) is currently developing an enhanced Huntsville Operation Support Center (HOSC) system designed to support multiple spacecraft missions. The Enhanced HOSC is based upon a distributed computing architecture using graphic workstation hardware and industry standard software including POSIX, X Windows, Motif, TCP/IP, and ANSI C. Southwest Research Institute (SwRI) is currently developing a prototype of the Display Services application for this system. Display Services provides the capability to generate and operate real-time data-driven graphic displays. This prototype is a highly functional application designed to allow system end users to easily generate complex data-driven displays. The prototype is easy to use, flexible, highly functional, and portable. Although this prototype is being developed for NASA-MSFC, the general-purpose real-time display capability can be reused in similar mission and process control environments. This includes any environment depending heavily upon real-time data acquisition and display. Reuse of the prototype will be a straight-forward transition because the prototype is portable, is designed to add new display types easily, has a user interface which is separated from the application code, and is very independent of the specifics of NASA-MSFC's system. Reuse of this prototype in other environments is a excellent alternative to creation of a new custom application, or for environments with a large number of users, to purchasing a COTS package.

  6. CMOS dot matrix microdisplay

    NASA Astrophysics Data System (ADS)

    Venter, Petrus J.; Bogalecki, Alfons W.; du Plessis, Monuko; Goosen, Marius E.; Nell, Ilse J.; Rademeyer, P.

    2011-03-01

    Display technologies always seem to find a wide range of interesting applications. As devices develop towards miniaturization, niche applications for small displays may emerge. While OLEDs and LCDs dominate the market for small displays, they have some shortcomings as relatively expensive technologies. Although CMOS is certainly not the dominating semiconductor for photonics, its widespread use, favourable cost and robustness present an attractive potential if it could find application in the microdisplay environment. Advances in improving the quantum efficiency of avalanche electroluminescence and the favourable spectral characteristics of light generated through the said mechanism may afford CMOS the possibility to be used as a display technology. This work shows that it is possible to integrate a fully functional display in a completely standard CMOS technology mainly geared towards digital design while using light sources completely compatible with the process and without any post processing required.

  7. Progressing from initially ambiguous functional analyses: three case examples.

    PubMed

    Tiger, Jeffrey H; Fisher, Wayne W; Toussaint, Karen A; Kodak, Tiffany

    2009-01-01

    Most often functional analyses are initiated using a standard set of test conditions, similar to those described by Iwata, Dorsey, Slifer, Bauman, and Richman [Iwata, B. A., Dorsey, M. F., Slifer, K. J., Bauman, K. E., & Richman, G. S. (1994). Toward a functional analysis of self-injury. Journal of Applied Behavior Analysis, 27, 197-209 (Reprinted from Analysis and Intervention in Developmental Disabilities, 2, 3-20, 1982)]. These test conditions involve the careful manipulation of motivating operations, discriminative stimuli, and reinforcement contingencies to determine the events related to the occurrence and maintenance of problem behavior. Some individuals display problem behavior that is occasioned and reinforced by idiosyncratic or otherwise unique combinations of environmental antecedents and consequences of behavior, which are unlikely to be detected using these standard assessment conditions. For these individuals, modifications to the standard test conditions or the inclusion of novel test conditions may result in clearer assessment outcomes. The current study provides three case examples of individuals whose functional analyses were initially undifferentiated; however, modifications to the standard conditions resulted in the identification of behavioral functions and the implementation of effective function-based treatments.

  8. Multimission image processing and science data visualization

    NASA Technical Reports Server (NTRS)

    Green, William B.

    1993-01-01

    The Operational Science Analysis (OSA) Functional area supports science instrument data display, analysis, visualization and photo processing in support of flight operations of planetary spacecraft managed by the Jet Propulsion Laboratory (JPL). This paper describes the data products generated by the OSA functional area, and the current computer system used to generate these data products. The objectives on a system upgrade now in process are described. The design approach to development of the new system are reviewed, including use of the Unix operating system and X-Window display standards to provide platform independence, portability, and modularity within the new system, is reviewed. The new system should provide a modular and scaleable capability supporting a variety of future missions at JPL.

  9. Accelerometer method and apparatus for integral display and control functions

    NASA Astrophysics Data System (ADS)

    Bozeman, Richard J., Jr.

    1992-06-01

    Vibration analysis has been used for years to provide a determination of the proper functioning of different types of machinery, including rotating machinery and rocket engines. A determination of a malfunction, if detected at a relatively early stage in its development, will allow changes in operating mode or a sequenced shutdown of the machinery prior to a total failure. Such preventative measures result in less extensive and/or less expensive repairs, and can also prevent a sometimes catastrophic failure of equipment. Standard vibration analyzers are generally rather complex, expensive, and of limited portability. They also usually result in displays and controls being located remotely from the machinery being monitored. Consequently, a need exists for improvements in accelerometer electronic display and control functions which are more suitable for operation directly on machines and which are not so expensive and complex. The invention includes methods and apparatus for detecting mechanical vibrations and outputting a signal in response thereto. The apparatus includes an accelerometer package having integral display and control functions. The accelerometer package is suitable for mounting upon the machinery to be monitored. Display circuitry provides signals to a bar graph display which may be used to monitor machine condition over a period of time. Control switches may be set which correspond to elements in the bar graph to provide an alert if vibration signals increase over the selected trip point. The circuitry is shock mounted within the accelerometer housing. The method provides for outputting a broadband analog accelerometer signal, integrating this signal to produce a velocity signal, integrating and calibrating the velocity signal before application to a display driver, and selecting a trip point at which a digitally compatible output signal is generated. The benefits of a vibration recording and monitoring system with controls and displays readily mountable on the machinery being monitored and having capabilities described will be appreciated by those working in the art.

  10. Accelerometer method and apparatus for integral display and control functions

    NASA Technical Reports Server (NTRS)

    Bozeman, Richard J., Jr. (Inventor)

    1992-01-01

    Vibration analysis has been used for years to provide a determination of the proper functioning of different types of machinery, including rotating machinery and rocket engines. A determination of a malfunction, if detected at a relatively early stage in its development, will allow changes in operating mode or a sequenced shutdown of the machinery prior to a total failure. Such preventative measures result in less extensive and/or less expensive repairs, and can also prevent a sometimes catastrophic failure of equipment. Standard vibration analyzers are generally rather complex, expensive, and of limited portability. They also usually result in displays and controls being located remotely from the machinery being monitored. Consequently, a need exists for improvements in accelerometer electronic display and control functions which are more suitable for operation directly on machines and which are not so expensive and complex. The invention includes methods and apparatus for detecting mechanical vibrations and outputting a signal in response thereto. The apparatus includes an accelerometer package having integral display and control functions. The accelerometer package is suitable for mounting upon the machinery to be monitored. Display circuitry provides signals to a bar graph display which may be used to monitor machine condition over a period of time. Control switches may be set which correspond to elements in the bar graph to provide an alert if vibration signals increase over the selected trip point. The circuitry is shock mounted within the accelerometer housing. The method provides for outputting a broadband analog accelerometer signal, integrating this signal to produce a velocity signal, integrating and calibrating the velocity signal before application to a display driver, and selecting a trip point at which a digitally compatible output signal is generated. The benefits of a vibration recording and monitoring system with controls and displays readily mountable on the machinery being monitored and having capabilities described will be appreciated by those working in the art.

  11. A comprehensive analysis of filamentous phage display vectors for cytoplasmic proteins: an analysis with different fluorescent proteins.

    PubMed

    Velappan, Nileena; Fisher, Hugh E; Pesavento, Emanuele; Chasteen, Leslie; D'Angelo, Sara; Kiss, Csaba; Longmire, Michelle; Pavlik, Peter; Bradbury, Andrew R M

    2010-03-01

    Filamentous phage display has been extensively used to select proteins with binding properties of specific interest. Although many different display platforms using filamentous phage have been described, no comprehensive comparison of their abilities to display similar proteins has been conducted. This is particularly important for the display of cytoplasmic proteins, which are often poorly displayed with standard filamentous phage vectors. In this article, we have analyzed the ability of filamentous phage to display a stable form of green fluorescent protein and modified variants in nine different display vectors, a number of which have been previously proposed as being suitable for cytoplasmic protein display. Correct folding and display were assessed by phagemid particle fluorescence, and with anti-GFP antibodies. The poor correlation between phagemid particle fluorescence and recognition of GFP by antibodies, indicates that proteins may fold correctly without being accessible for display. The best vector used a twin arginine transporter leader to transport the displayed protein to the periplasm, and a coil-coil arrangement to link the displayed protein to g3p. This vector was able to display less robust forms of GFP, including ones with inserted epitopes, as well as fluorescent proteins of the Azami green series. It was also functional in mock selection experiments.

  12. Comparison of two head-up displays in simulated standard and noise abatement night visual approaches

    NASA Technical Reports Server (NTRS)

    Cronn, F.; Palmer, E. A., III

    1975-01-01

    Situation and command head-up displays were evaluated for both standard and two segment noise abatement night visual approaches in a fixed base simulation of a DC-8 transport aircraft. The situation display provided glide slope and pitch attitude information. The command display provided glide slope information and flight path commands to capture a 3 deg glide slope. Landing approaches were flown in both zero wind and wind shear conditions. For both standard and noise abatement approaches, the situation display provided greater glidepath accuracy in the initial phase of the landing approaches, whereas the command display was more effective in the final approach phase. Glidepath accuracy was greater for the standard approaches than for the noise abatement approaches in all phases of the landing approach. Most of the pilots preferred the command display and the standard approach. Substantial agreement was found between each pilot's judgment of his performance and his actual performance.

  13. WE-E-12A-01: Medical Physics 1.0 to 2.0: MRI, Displays, Informatics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pickens, D; Flynn, M; Peck, D

    Medical Physics 2.0 is a bold vision for an existential transition of clinical imaging physics in face of the new realities of value-based and evidence-based medicine, comparative effectiveness, and meaningful use. It speaks to how clinical imaging physics can expand beyond traditional insular models of inspection and acceptance testing, oriented toward compliance, towards team-based models of operational engagement, prospective definition and assurance of effective use, and retrospective evaluation of clinical performance. Organized into four sessions of the AAPM, this particular session focuses on three specific modalities as outlined below. MRI 2.0: This presentation will look into the future of clinicalmore » MR imaging and what the clinical medical physicist will need to be doing as the technology of MR imaging evolves. Many of the measurement techniques used today will need to be expanded to address the advent of higher field imaging systems and dedicated imagers for specialty applications. Included will be the need to address quality assurance and testing metrics for multi-channel MR imagers and hybrid devices such as MR/PET systems. New pulse sequences and acquisition methods, increasing use of MR spectroscopy, and real-time guidance procedures will place the burden on the medical physicist to define and use new tools to properly evaluate these systems, but the clinical applications must be understood so that these tools are use correctly. Finally, new rules, clinical requirements, and regulations will mean that the medical physicist must actively work to keep her/his sites compliant and must work closely with physicians to ensure best performance of these systems. Informatics Display 1.0 to 2.0: Medical displays are an integral part of medical imaging operation. The DICOM and AAPM (TG18) efforts have led to clear definitions of performance requirements of monochrome medical displays that can be followed by medical physicists to ensure proper performance. However, effective implementation of that oversight has been challenging due to the number and extend of medical displays in use at a facility. The advent of color display and mobile displays has added additional challenges to the task of the medical physicist. This informatics display lecture first addresses the current display guidelines (the 1.0 paradigm) and further outlines the initiatives and prospects for color and mobile displays (the 2.0 paradigm). Informatics Management 1.0 to 2.0: Imaging informatics is part of every radiology practice today. Imaging informatics covers everything from the ordering of a study, through the data acquisition and processing, display and archiving, reporting of findings and the billing for the services performed. The standardization of the processes used to manage the information and methodologies to integrate these standards is being developed and advanced continuously. These developments are done in an open forum and imaging organizations and professionals all have a part in the process. In the Informatics Management presentation, the flow of information and the integration of the standards used in the processes will be reviewed. The role of radiologists and physicists in the process will be discussed. Current methods (the 1.0 paradigm) and evolving methods (the 2.0 paradigm) for validation of informatics systems function will also be discussed. Learning Objectives: Identify requirements for improving quality assurance and compliance tools for advanced and hybrid MRI systems. Identify the need for new quality assurance metrics and testing procedures for advanced systems. Identify new hardware systems and new procedures needed to evaluate MRI systems. Understand the components of current medical physics expectation for medical displays. Understand the role and prospect fo medical physics for color and mobile display devices. Understand different areas of imaging informatics and the methodology for developing informatics standards. Understand the current status of informatics standards and the role of physicists and radiologists in the process, and the current technology for validating the function of these systems.« less

  14. Exercise training reinstates cortico-cortical sensorimotor functional connectivity following striatal lesioning: Development and application of a subregional-level analytic toolbox for perfusion autoradiographs of the rat brain

    NASA Astrophysics Data System (ADS)

    Peng, Yu-Hao; Heintz, Ryan; Wang, Zhuo; Guo, Yumei; Myers, Kalisa; Scremin, Oscar; Maarek, Jean-Michel; Holschneider, Daniel

    2014-12-01

    Current rodent connectome projects are revealing brain structural connectivity with unprecedented resolution and completeness. How subregional structural connectivity relates to subregional functional interactions is an emerging research topic. We describe a method for standardized, mesoscopic-level data sampling from autoradiographic coronal sections of the rat brain, and for correlation-based analysis and intuitive display of cortico-cortical functional connectivity (FC) on a flattened cortical map. A graphic user interface “Cx-2D” allows for the display of significant correlations of individual regions-of-interest, as well as graph theoretical metrics across the cortex. Cx-2D was tested on an autoradiographic data set of cerebral blood flow (CBF) of rats that had undergone bilateral striatal lesions, followed by 4 weeks of aerobic exercise training or no exercise. Effects of lesioning and exercise on cortico-cortical FC were examined during a locomotor challenge in this rat model of Parkinsonism. Subregional FC analysis revealed a rich functional reorganization of the brain in response to lesioning and exercise that was not apparent in a standard analysis focused on CBF of isolated brain regions. Lesioned rats showed diminished degree centrality of lateral primary motor cortex, as well as neighboring somatosensory cortex--changes that were substantially reversed in lesioned rats following exercise training. Seed analysis revealed that exercise increased positive correlations in motor and somatosensory cortex, with little effect in non-sensorimotor regions such as visual, auditory, and piriform cortex. The current analysis revealed that exercise partially reinstated sensorimotor FC lost following dopaminergic deafferentation. Cx-2D allows for standardized data sampling from images of brain slices, as well as analysis and display of cortico-cortical FC in the rat cerebral cortex with potential applications in a variety of autoradiographic and histologic studies.

  15. Interactive displays in medical art

    NASA Technical Reports Server (NTRS)

    Mcconathy, Deirdre Alla; Doyle, Michael

    1989-01-01

    Medical illustration is a field of visual communication with a long history. Traditional medical illustrations are static, 2-D, printed images; highly realistic depictions of the gross morphology of anatomical structures. Today medicine requires the visualization of structures and processes that have never before been seen. Complex 3-D spatial relationships require interpretation from 2-D diagnostic imagery. Pictures that move in real time have become clinical and research tools for physicians. Medical illustrators are involved with the development of interactive visual displays for three different, but not discrete, functions: as educational materials, as clinical and research tools, and as data bases of standard imagery used to produce visuals. The production of interactive displays in the medical arts is examined.

  16. Design and Development of Functionally Effective Human-Machine Interfaces for Firing Room Displays

    NASA Technical Reports Server (NTRS)

    Cho, Henry

    2013-01-01

    This project involves creating software for support equipment used on the Space Launch System (SLS). The goal is to create applications and displays that will be used to remotely operate equipment from the firing room and will continue to support the SLS launch vehicle to the extent of its program. These displays include design practices that help to convey information effectively, such as minimizing distractions at normal operating state and displaying intentional distractions during a warning or alarm state. The general practice for creating an operator display is to reduce the detail of unimportant aspects of the display and promote focus on data and dynamic information. These practices include using minimalist design, using muted tones for background colors, using a standard font at a readable text size, displaying alarms visible for immediate attention, grouping data logically, and displaying data appropriately varying on the type of data. Users of these displays are more likely to stay focused on operating for longer periods by using design practices that reduce eye strain and fatigue. Effective operator displays will improve safety by reducing human errors during operation, which will help prevent catastrophic accidents. This report entails the details of my work on developing remote displays for the Hypergolic fuel servicing system. Before developing a prototype display, the design and requirements of the system are outlined and compiled into a document. Then each subsystem has schematic representations drawn that meet the specifications detailed in the document. The schematics are then used as the outline to create display representations of each subsystem. Each display is first tested individually. Then the displays are integrated with a prototype of the master system, and they are tested in a simulated environment then retested in the real environment. Extensive testing is important to ensure the displays function reliably as intended.

  17. Design and Development of Functionally Effective Human-Machine Interfaces for Firing Room Displays

    NASA Technical Reports Server (NTRS)

    Cho, Henry

    2013-01-01

    This project involves creating software for support equipment used on the Space l aunch System (SLS). The goal is to create applications and displays that will be used to remotely operate equipment from the firing room and will continue to support the SLS launch vehicle to the extent of its program. These displays include design practices that help to convey information effectively, such as minimizing distractions at normal operating state and displaying intentional distractions during a warning or alarm state. The general practice for creating an operator display is to reduce the detail of unimportant aspects of the display and promote focus on data and dynamic information. These practices include using minimalist design, using muted tones for background colors, using a standard font at a readable text size, displaying alarms visible for Immediate attention, grouping data logically, and displaying data appropriately varying on the type of data. Users of these displays are more likely to stay focused on operating for longer periods by using design practices that reduce eye strain and fatigue. Effective operator displays will improve safety by reducing human errors during operation, which will help prevent catastrophic accidents. This report entails the details of my work on developing remote displays for the Hypergolics ground system. Before developing a prototype display, the design and requirements of the system are outlined and compiled into a document. Then each subsystem has schematic representations drawn tha.t meet the specifications detailed in the document. The schematics are then used as the outline to create display representations of each subsystem. Each display is first tested individually. Then the displays are integrated with a prototype of the master system, and they are tested in a simulated environment then retested in the real environment. Extensive testing is important to ensure the displays function reliably as intended.

  18. Accessibility of Home Blood Pressure Monitors for Blind and Visually Impaired People

    PubMed Central

    Uslan, Mark M.; Burton, Darren M.; Wilson, Thomas E.; Taylor, Steven; Chertow, Bruce S.; Terry, Jack E.

    2007-01-01

    Background The prevalence of hypertension comorbid with diabetes is a significant health care issue. Use of the home blood pressure monitor (HBPM) for aiding in the control of hypertension is noteworthy because of benefits that accrue from following a home measurement regimen. To be usable by blind and visually impaired patients, HBPMs must have speech output to convey all screen information, an easily readable visual display, identifiable controls that are easy to use, and an accessible user manual. Methods Data on the physical aspects and the features and functions of nine Food and Drug Administration-approved HBPMs (eight of which were recommended by the British Hypertension Society) were tabulated and analyzed for usability by blind and visually impaired individuals. Video Electronics Standards Association standards were used to measure contrast modulation in the displays of the HBPMs. Ten persons who are blind or visually impaired and who have diabetes were surveyed to determine how they monitor their blood pressure and to learn their ideas for improvements in usability. Results Physical controls were found to be easy to identify, and operating procedures were found to be relatively simple on all of the HBPMs, but user manuals were either inaccessible or minimally accessible to blind persons. The two HBPMs that have speech output do not voice all of the information that is displayed on the screen. Some functions that are standard in the HBPMs without speech output, such as the feature for automatically setting cuff inflation volume and memory, were lacking in the HBPMs with speech output. These features were mentioned as desirable in interviews with legally blind persons who are diabetic and who monitor their blood pressure at home. Visual display output was large and adequate in all of the HBPMs. Michelson contrast for numeric digits in the HBPM displays was also measured, ranging from 55 to 75% for characters with dominant spatial frequency components lying in the range of 0.5–1.0 cycles/degree. Conclusions Home blood pressure monitors are easy-to-use devices that do not present accessibility barriers that are difficult to surmount, either technically or operationally. Two HBPMs with voice output were found to have a significant degree of accessibility, but they were not found to offer as many features as those HBPMs that were less accessible. Recommendations were made to improve accessibility, including the development of visual display standards that specify a minimally acceptable level of Michelson contrast. PMID:19888410

  19. Are New Image Quality Figures of Merit Needed for Flat Panel Displays?

    DTIC Science & Technology

    1998-06-01

    American National Standard for Human Factors Engineering of Visual Display Terminal Workstations in 1988 have adopted the MTFA as the standard...References American National Standard for Human Factors Engineering of Visual Display Terminal Workstations (ANSI/HFS 100-1988). 1988. Santa Monica

  20. Standardization: colorfull or dull?

    NASA Astrophysics Data System (ADS)

    van Nes, Floris L.

    2003-01-01

    After mentioning the necessity of standardization in general, this paper explains how human factors, or ergonomics standardization by ISO and the deployment of information technology were linked. Visual display standardization is the main topic; the present as well as the future situation in this field are treated, mainly from an ISO viewpoint. Some observations are made about the necessary and interesting co-operation between physicists and psychologists, of different nationality, who both may be employed by either private enterprise or governmental institutions, in determining visual display requirements. The display standard that is to succeed the present ISO standards in this area: ISO 9241-3, -7, -8 and ISO 13406-1, -2, will have a scope that is not restricted to office tasks. This means a large extension of the contexts for which display requirements have to be investigated and specified especially if mobile use of displays, under outdoor lighting conditions, is included. The new standard will be structured in such a way that it is better accessible than the present ones for different categories of standards users. The subject color in the new standard is elaborated here. A number of questions are asked as to which requirements on color rendering should be made, taking new research results into account, and how far the new standard should go in making recommendations to the display user.

  1. Metasecretome-selective phage display approach for mining the functional potential of a rumen microbial community.

    PubMed

    Ciric, Milica; Moon, Christina D; Leahy, Sinead C; Creevey, Christopher J; Altermann, Eric; Attwood, Graeme T; Rakonjac, Jasna; Gagic, Dragana

    2014-05-12

    In silico, secretome proteins can be predicted from completely sequenced genomes using various available algorithms that identify membrane-targeting sequences. For metasecretome (collection of surface, secreted and transmembrane proteins from environmental microbial communities) this approach is impractical, considering that the metasecretome open reading frames (ORFs) comprise only 10% to 30% of total metagenome, and are poorly represented in the dataset due to overall low coverage of metagenomic gene pool, even in large-scale projects. By combining secretome-selective phage display and next-generation sequencing, we focused the sequence analysis of complex rumen microbial community on the metasecretome component of the metagenome. This approach achieved high enrichment (29 fold) of secreted fibrolytic enzymes from the plant-adherent microbial community of the bovine rumen. In particular, we identified hundreds of heretofore rare modules belonging to cellulosomes, cell-surface complexes specialised for recognition and degradation of the plant fibre. As a method, metasecretome phage display combined with next-generation sequencing has a power to sample the diversity of low-abundance surface and secreted proteins that would otherwise require exceptionally large metagenomic sequencing projects. As a resource, metasecretome display library backed by the dataset obtained by next-generation sequencing is ready for i) affinity selection by standard phage display methodology and ii) easy purification of displayed proteins as part of the virion for individual functional analysis.

  2. Evaluation of tablet computers for visual function assessment.

    PubMed

    Bodduluri, Lakshmi; Boon, Mei Ying; Dain, Stephen J

    2017-04-01

    Recent advances in technology and the increased use of tablet computers for mobile health applications such as vision testing necessitate an understanding of the behavior of the displays of such devices, to facilitate the reproduction of existing or the development of new vision assessment tests. The purpose of this study was to investigate the physical characteristics of one model of tablet computer (iPad mini Retina display) with regard to display consistency across a set of devices (15) and their potential application as clinical vision assessment tools. Once the tablet computer was switched on, it required about 13 min to reach luminance stability, while chromaticity remained constant. The luminance output of the device remained stable until a battery level of 5%. Luminance varied from center to peripheral locations of the display and with viewing angle, whereas the chromaticity did not vary. A minimal (1%) variation in luminance was observed due to temperature, and once again chromaticity remained constant. Also, these devices showed good temporal stability of luminance and chromaticity. All 15 tablet computers showed gamma functions approximating the standard gamma (2.20) and showed similar color gamut sizes, except for the blue primary, which displayed minimal variations. The physical characteristics across the 15 devices were similar and are known, thereby facilitating the use of this model of tablet computer as visual stimulus displays.

  3. Aircraft Alerting Systems Standardization Study. Phase IV. Accident Implications on Systems Design.

    DTIC Science & Technology

    1982-06-01

    computing and processing to assimilate and process status informa- 5 tion using...provided with capabilities in computing and processing , sensing, interfacing, and controlling and displaying. 17 o Computing and Processing - Algorithms...alerting system to perform a flight status monitor function would require additional sensinq, computing and processing , interfacing, and controlling

  4. Information Management Functional Economic Analysis for Finance Workstations to the Defense Information Technology Services Organization

    DTIC Science & Technology

    1993-03-01

    values themselves. The Wools perform risk-adjusted present-value comparisons and compute the ROI using discount factors. The assessment of risk in a...developed X Window system, the de facto industry standard window system in the UNIX environment. An X- terminal’s use is limited to display. It has no...2.1 IT HARDWARE The DOS-based PC used in this analysis costs $2,060. It includes an ASL 486DX-33 Industry Standard Architecture (ISA) computer with 8

  5. Characterization of solar cells for space applications. Volume 5: Electrical characteristics of OCLI 225-micron MLAR wraparound cells as a function of intensity, temperature, and irradiation

    NASA Technical Reports Server (NTRS)

    Anspaugh, B. E.; Miyahira, T. F.; Weiss, R. S.

    1979-01-01

    Computed statistical averages and standard deviations with respect to the measured cells for each intensity temperature measurement condition are presented. Display averages and standard deviations of the cell characteristics in a two dimensional array format are shown: one dimension representing incoming light intensity, and another, the cell temperature. Programs for calculating the temperature coefficients of the pertinent cell electrical parameters are presented, and postirradiation data are summarized.

  6. Monitoring pulmonary function with superimposed pulmonary gas exchange curves from standard analyzers.

    PubMed

    Zar, Harvey A; Noe, Frances E; Szalados, James E; Goodrich, Michael D; Busby, Michael G

    2002-01-01

    A repetitive graphic display of the single breath pulmonary function can indicate changes in cardiac and pulmonary physiology brought on by clinical events. Parallel advances in computer technology and monitoring make real-time, single breath pulmonary function clinically practicable. We describe a system built from a commercially available airway gas monitor and off the shelf computer and data-acquisition hardware. Analog data for gas flow rate, O2, and CO2 concentrations are introduced into a computer through an analog-to-digital conversion board. Oxygen uptake (VO2) and carbon dioxide output (VCO2) are calculated for each breath. Inspired minus expired concentrations for O2 and CO2 are displayed simultaneously with the expired gas flow rate curve for each breath. Dead-space and alveolar ventilation are calculated for each breath and readily appreciated from the display. Graphs illustrating the function of the system are presented for the following clinical scenarios; upper airway obstruction, bronchospasm, bronchopleural fistula, pulmonary perfusion changes and inadequate oxygen delivery. This paper describes a real-time, single breath pulmonary monitoring system that displays three parameters graphed against time: expired flow rate, oxygen uptake and carbon dioxide production. This system allows for early and rapid recognition of treatable conditions that may lead to adverse events without any additional patient measurements or invasive procedures. Monitoring systems similar to the one described in this paper may lead to a higher level of patient safety without any additional patient risk.

  7. Visual Speech-Training Aid for the Deaf

    NASA Technical Reports Server (NTRS)

    Miller, Robert J.

    1987-01-01

    Teaching deaf to speak aided by electronic system provides striking colored, pictorial representation of sound; energy at different frequencies as function of time. Other modalities, such as nasality, intra-oral pressure, and lip-muscle contraction, pictorialized simultaneously. Use of standard components, including personal microcomputer, helps reduce cost below prior voice-training systems. Speech-training system, microphone output separated by filters into narrow frequency bands, changed into digital signals, formatted by computer, and displayed on television screen. Output from other sensors displayed simultaneously or screen split to allow sound produced by student to be compared with that of teacher.

  8. Improving the interactivity and functionality of Web-based radiology teaching files with the Java programming language.

    PubMed

    Eng, J

    1997-01-01

    Java is a programming language that runs on a "virtual machine" built into World Wide Web (WWW)-browsing programs on multiple hardware platforms. Web pages were developed with Java to enable Web-browsing programs to overlay transparent graphics and text on displayed images so that the user could control the display of labels and annotations on the images, a key feature not available with standard Web pages. This feature was extended to include the presentation of normal radiologic anatomy. Java programming was also used to make Web browsers compatible with the Digital Imaging and Communications in Medicine (DICOM) file format. By enhancing the functionality of Web pages, Java technology should provide greater incentive for using a Web-based approach in the development of radiology teaching material.

  9. Overview of FTV (free-viewpoint television)

    NASA Astrophysics Data System (ADS)

    Tanimoto, Masayuki

    2010-07-01

    We have developed a new type of television named FTV (Free-viewpoint TV). FTV is the ultimate 3DTV that enables us to view a 3D scene by freely changing our viewpoints. We proposed the concept of FTV and constructed the world's first real-time system including the complete chain of operation from image capture to display. FTV is based on the rayspace method that represents one ray in real space with one point in the ray-space. We have developed ray capture, processing and display technologies for FTV. FTV can be carried out today in real time on a single PC or on a mobile player. We also realized FTV with free listening-point audio. The international standardization of FTV has been conducted in MPEG. The first phase of FTV was MVC (Multi-view Video Coding) and the second phase is 3DV (3D Video). MVC was completed in May 2009. The Blu-ray 3D specification has adopted MVC for compression. 3DV is a standard that targets serving a variety of 3D displays. The view generation function of FTV is used to decouple capture and display in 3DV. FDU (FTV Data Unit) is proposed as a data format for 3DV. FTU can compensate errors of the synthesized views caused by depth error.

  10. Quantitative evaluation of three advanced laparoscopic viewing technologies: a stereo endoscope, an image projection display, and a TFT display.

    PubMed

    Wentink, M; Jakimowicz, J J; Vos, L M; Meijer, D W; Wieringa, P A

    2002-08-01

    Compared to open surgery, minimally invasive surgery (MIS) relies heavily on advanced technology, such as endoscopic viewing systems and innovative instruments. The aim of the study was to objectively compare three technologically advanced laparoscopic viewing systems with the standard viewing system currently used in most Dutch hospitals. We evaluated the following advanced laparoscopic viewing systems: a Thin Film Transistor (TFT) display, a stereo endoscope, and an image projection display. The standard viewing system was comprised of a monocular endoscope and a high-resolution monitor. Task completion time served as the measure of performance. Eight surgeons with laparoscopic experience participated in the experiment. The average task time was significantly greater (p <0.05) with the stereo viewing system than with the standard viewing system. The average task times with the TFT display and the image projection display did not differ significantly from the standard viewing system. Although the stereo viewing system promises improved depth perception and the TFT and image projection displays are supposed to improve hand-eye coordination, none of these systems provided better task performance than the standard viewing system in this pelvi-trainer experiment.

  11. Flight tests of the 4D flight guidance display

    NASA Astrophysics Data System (ADS)

    Below, Christian; von Viebahn, Harro; Purpus, Matthias

    1997-06-01

    A perspective primary flight and a navigation display format were evaluated in a flying testbed. The flight tests comprised ILS- and standard approaches as well as low level operations utilizing the depiction of a spatial channel, and demonstrations of the inherent ground proximity warning function. In the cockpit of the VFW614, the left seat was equipped with a sidestick and a flat panel display, which showed both the 4D-display an the Navigation Display format. Airline and airforce pilots flew several missions each. Although most of the pilots criticizes that a typical flight director commanding the aircraft's attitude was missing, they could follow the channel precisely. However, some airline pilots stated a lack of vertical guidance information during the final approach. Leaving and re- entering the channel could be easily accomplished form any direction. In summary pilots' assessment of the display concept yielded an overall improvement of SA. In particular it was stated that displays are an appropriate means to avoid CFIT accidents. With the fist prototypes of 3D- graphics generators designed for avionics available the flight evaluation will continue including feasibility demonstrations of high-performance graphics for civil and military aircraft applications.

  12. Image quality metrics for volumetric laser displays

    NASA Astrophysics Data System (ADS)

    Williams, Rodney D.; Donohoo, Daniel

    1991-08-01

    This paper addresses the extensions to the image quality metrics and related human factors research that are needed to establish the baseline standards for emerging volume display technologies. The existing and recently developed technologies for multiplanar volume displays are reviewed with an emphasis on basic human visual issues. Human factors image quality metrics and guidelines are needed to firmly establish this technology in the marketplace. The human visual requirements and the display design tradeoffs for these prototype laser-based volume displays are addressed and several critical image quality issues identified for further research. The American National Standard for Human Factors Engineering of Visual Display Terminal Workstations (ANSIHFS-100) and other international standards (ISO, DIN) can serve as a starting point, but this research base must be extended to provide new image quality metrics for this new technology for volume displays.

  13. Flight simulator evaluation of a novel flight instrument display to minimize the risks of spatial disorientation.

    PubMed

    Braithwaite, M G; Durnford, S J; Groh, S L; Jones, H D; Higdon, A A; Estrada, A; Alvarez, E A

    1998-08-01

    Spatial disorientation (SD) in flight remains a major source of attrition. Many SD accidents would occur regardless of the instrument display in use, since the aircrew are simply not looking at the instruments. However, there are a number of accidents which might be amenable to improved instrument displays. In an attempt to improve maintenance and reattainment of correct orientation with a reduced cognitive workload, a novel instrument display has been developed. This paper describes an assessment of the display in a UH-60 helicopter flight simulator. This study tested the hypothesis that during instrument flight and recovery from unusual attitudes, the novel display permits a more accurate maintenance and reestablishment of flight parameters than the standard flight instruments. There were 16 male aviators who flew a simulated instrument flight profile and recovery from unusual attitudes using both the standard flight instruments and the novel display. The two display formats were tested both with and without a secondary task. When compared with the standard instruments, both control of flight parameters and recovery from unusual attitudes were significantly improved when using the novel display. Analysis of the secondary task scores showed that cognitive workload was reduced when using the novel display compared with the standard instruments. Results from all aspects of the assessment indicated benefits of the new display. Future testing should be carried out during real flight, and the display should be further developed to be used in a head-up or helmet-mounted device.

  14. A visual detection model for DCT coefficient quantization

    NASA Technical Reports Server (NTRS)

    Ahumada, Albert J., Jr.; Peterson, Heidi A.

    1993-01-01

    The discrete cosine transform (DCT) is widely used in image compression, and is part of the JPEG and MPEG compression standards. The degree of compression, and the amount of distortion in the decompressed image are determined by the quantization of the transform coefficients. The standards do not specify how the DCT coefficients should be quantized. Our approach is to set the quantization level for each coefficient so that the quantization error is at the threshold of visibility. Here we combine results from our previous work to form our current best detection model for DCT coefficient quantization noise. This model predicts sensitivity as a function of display parameters, enabling quantization matrices to be designed for display situations varying in luminance, veiling light, and spatial frequency related conditions (pixel size, viewing distance, and aspect ratio). It also allows arbitrary color space directions for the representation of color.

  15. Flat panel display test and evaluation: procedures, standards, and facilities

    NASA Astrophysics Data System (ADS)

    Jackson, Timothy W.; Daniels, Reginald; Hopper, Darrel G.

    1997-07-01

    This paper addresses flat panel display test and evaluation via a discussion of procedures, standards and facilities. Procedures need to be carefully developed and documented to ensure that test accomplished in separate laboratories produce comparable results. The tests themselves must not be a source of inconsistency in test results when such comparisons are made in the course of procurements or new technology prototype evaluations. Standards are necessary to expedite the transition of the new display technologies into applications and to lower the costs of custom parts applied across disparate applications. The flat panel display industry is in the course of ascertaining and formulating such standards as they are of value to designers, manufacturers, marketers and users of civil and military products and equipment. Additionally, in order to inform the DoD and industry, the test and evaluation facilities of the Air Force Research Laboratory Displays Branch are described. These facilities are available to support procurements involving flat panel displays and to examine new technology prototypes. Finally, other government display testing facilities within the Navy and the Army are described.

  16. How to use a phase-only spatial light modulator as a color display.

    PubMed

    Harm, Walter; Jesacher, Alexander; Thalhammer, Gregor; Bernet, Stefan; Ritsch-Marte, Monika

    2015-02-15

    We demonstrate that a parallel aligned liquid crystal on silicon (PA-LCOS) spatial light modulator (SLM) without any attached color mask can be used as a full color display with white light illumination. The method is based on the wavelength dependence of the (voltage controlled) birefringence of the liquid crystal pixels. Modern SLMs offer a wide range over which the birefringence can be modulated, leading (in combination with a linear polarizer) to several intensity modulation periods of a reflected light wave as a function of the applied voltage. Because of dispersion, the oscillation period strongly depends on the wavelength. Thus each voltage applied to an SLM pixel corresponds to another reflected color spectrum. For SLMs with a sufficiently broad tuning range, one obtains a color palette (i.e., a "color lookup-table"), which allows one to display color images. An advantage over standard liquid crystal displays (LCDs), which use color masks in front of the individual pixels, is that the light efficiency and the display resolution are increased by a factor of three.

  17. Validation of Minimum Display Requirements for a UAS Detect and Avoid System

    NASA Technical Reports Server (NTRS)

    Rorie, Conrad; Fern, Lisa; Roberts, Zach; Monk, Kevin; Santiago, Confesor; Shively, Jay

    2017-01-01

    The full integration of Unmanned Aircraft Systems (UAS) into the National Airspace System (NAS), a prerequisite for enabling a broad range of public and commercial UAS operations, presents several technical challenges to UAS developers, operators and regulators. A primary barrier is the inability for UAS pilots (situated at a ground control station, or GCS) to comply with Title 14 Code of Federal Regulations sections 91.111 and 91.113, which require pilots to see and avoid other aircraft in order to maintain well clear. The present study is the final in a series of human-in-the-loop experiments designed to explore and test the various display and alerting requirements being incorporated into the minimum operational performance standards (MOPS) for a UAS-specific detect and avoid system that would replace the see and avoid function required of manned aircraft. Two display configurations were tested - an integrated display and a standalone display - and their impact on pilot response times and ability to maintain DAA well clear were compared. Results indicated that the current draft of the MOPS result in high-level performance and did not meaningfully differ by display configuration.

  18. The QDP/PLT user's guide

    NASA Technical Reports Server (NTRS)

    Tennant, Allyn F.

    1991-01-01

    PLT is a high level plotting package. A Programmer can create a default plot suited for the data being displayed. At run times, users can then interact with the plot overriding any or all of these defaults. The user is also provided the capability to fit functions to the displayed data. This ability to display, interact with, and to fit the data make PLT a useful tool in the analysis of data. The Quick and Dandy Plotter (QDP) program will read ASCII text files that contain PLT commands and data. Thus, QDP provides and easy way to use the PLT software QPD files provide a convenient way to exchange data. The QPD/PLT software is written in standard FORTRAN 77 and has been ported to VAX VMS, SUN UNIX, IBM AIX, NeXT NextStep, and MS-DOS systems.

  19. Lighting Control System for Premises with Display Screen Equipment

    NASA Astrophysics Data System (ADS)

    Kudryashov, A. V.

    2017-11-01

    The use of Display Screen Equipment (DSE) at enterprises allows one to increase the productivity and safety of production, minimize the number of personnel and leads to the simplification of the work of specialists, but on the other side, changes usual working conditions. If the personnel works with displays, visual fatigue develops more quickly which contributes to the emergence of nervous tension, stress and possible erroneous actions. Low interest of the lighting control system developers towards the rooms with displays is dictated by special requirements for coverage by sanitary and hygienic standards (limiting excess workplace illumination). We decided to create a combined lighting system which works considering daylight illumination and artificial light sources. The brightness adjustment of the LED lamps is carried out according to the DALI protocol, adjustment of the natural illumination by means of smart glasses. The technical requirements for a lighting control system, the structural-functional scheme and the algorithm for controlling the operation of the system have been developed. The elements of control units, sensors and actuators have been selected.

  20. Quantitative evaluation of Candia antarctica lipase B displayed on the cell surface of a Pichia pastoris based on an FS anchor system.

    PubMed

    Liang, Xing-xiang; Wang, Bei-bei; Sun, Yu-fei; Lin, Ying; Han, Shuang-yan; Zheng, Sui-ping; Cui, Tang-bing

    2013-03-01

    A new approach is described to quantify the number of enzyme molecules, such as Candia antarctica lipase B, that are displayed on the cell surface of Pichia pastoris. Enhanced green fluorescent protein (EGFP) and Candida antarctica lipase B (CALB) were fused and displayed on the surface of P. pastoris by linking to the anchor flocculation functional domain of FLO1p from Saccharomyces cerevisiae. Confocal laser scanning microscopy, flow cytometry, and fluorescence spectrophotometry were used to monitor the fluorescence intensity of fused EGFP. Combined with the corresponding protein concentration detected in the medium, a standard curve describing the relationship between the fusion protein concentration and fluorescence intensity were obtained and could be used to number CALB displayed on the cell surface. The results showed that approx. 10(4) molecules of CALB molecules were immobilized on the single P. pastoris cell wall based on FS anchor system.

  1. Implementation of the AES as a Hash Function for Confirming the Identity of Software on a Computer System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hansen, Randy R.; Bass, Robert B.; Kouzes, Richard T.

    2003-01-20

    This paper provides a brief overview of the implementation of the Advanced Encryption Standard (AES) as a hash function for confirming the identity of software resident on a computer system. The PNNL Software Authentication team chose to use a hash function to confirm software identity on a system for situations where: (1) there is limited time to perform the confirmation and (2) access to the system is restricted to keyboard or thumbwheel input and output can only be displayed on a monitor. PNNL reviewed three popular algorithms: the Secure Hash Algorithm - 1 (SHA-1), the Message Digest - 5 (MD-5),more » and the Advanced Encryption Standard (AES) and selected the AES to incorporate in software confirmation tool we developed. This paper gives a brief overview of the SHA-1, MD-5, and the AES and sites references for further detail. It then explains the overall processing steps of the AES to reduce a large amount of generic data-the plain text, such is present in memory and other data storage media in a computer system, to a small amount of data-the hash digest, which is a mathematically unique representation or signature of the former that could be displayed on a computer's monitor. This paper starts with a simple definition and example to illustrate the use of a hash function. It concludes with a description of how the software confirmation tool uses the hash function to confirm the identity of software on a computer system.« less

  2. IMAGEP - A FORTRAN ALGORITHM FOR DIGITAL IMAGE PROCESSING

    NASA Technical Reports Server (NTRS)

    Roth, D. J.

    1994-01-01

    IMAGEP is a FORTRAN computer algorithm containing various image processing, analysis, and enhancement functions. It is a keyboard-driven program organized into nine subroutines. Within the subroutines are other routines, also, selected via keyboard. Some of the functions performed by IMAGEP include digitization, storage and retrieval of images; image enhancement by contrast expansion, addition and subtraction, magnification, inversion, and bit shifting; display and movement of cursor; display of grey level histogram of image; and display of the variation of grey level intensity as a function of image position. This algorithm has possible scientific, industrial, and biomedical applications in material flaw studies, steel and ore analysis, and pathology, respectively. IMAGEP is written in VAX FORTRAN for DEC VAX series computers running VMS. The program requires the use of a Grinnell 274 image processor which can be obtained from Mark McCloud Associates, Campbell, CA. An object library of the required GMR series software is included on the distribution media. IMAGEP requires 1Mb of RAM for execution. The standard distribution medium for this program is a 1600 BPI 9track magnetic tape in VAX FILES-11 format. It is also available on a TK50 tape cartridge in VAX FILES-11 format. This program was developed in 1991. DEC, VAX, VMS, and TK50 are trademarks of Digital Equipment Corporation.

  3. Schematic displays for the Space Shuttle Orbiter multifunction cathode-ray-tube display system

    NASA Technical Reports Server (NTRS)

    Weiss, W.

    1979-01-01

    A standardized procedure for developing cathode ray tube displayed schematic diagrams. The displaying of Spacelab information on the space shuttle orbiter multifunction cathode ray tube display system is used to illustrate this procedure. Schematic displays with the equivalent tabular displays are compared.

  4. Identification of Useful Nanobodies by Phage Display of Immune Single Domain Libraries Derived from Camelid Heavy Chain Antibodies.

    PubMed

    Romao, Ema; Morales-Yanez, Francisco; Hu, Yaozhong; Crauwels, Maxine; De Pauw, Pieter; Hassanzadeh, Gholamreza Ghassanzadeh; Devoogdt, Nick; Ackaert, Chloe; Vincke, Cecile; Muyldermans, Serge

    2016-01-01

    The discovery of functional heavy chain-only antibodies devoid of light chains in sera of camelids and sharks in the early nineties provided access to the generation of minimal-sized, single-domain, in vivo affinity-matured, recombinant antigenbinding fragments, also known as Nanobodies. Recombinant DNA technology and adaptation of phage display vectors form the basis to construct large naïve, synthetic or medium sized immune libraries from where multiple Nanobodies have been retrieved. Alternative selection methods (i.e. bacterial display, bacterial two-hybrid, Cis-display and ribosome display) have also been developed to identify Nanobodies. The antigen affinity, stability, expression yields and structural details of the Nanobodies have been determined by standard technology. Nanobodies were subsequently engineered for higher stability and affinity, to have a sequence closer to that of human immunoglobulin domains, or to add designed effector functions. Antigen specific Nanobodies recognizing with high affinity their cognate antigen were retrieved from various libraries. High expression yields are obtained from microorganisms, even when expressed in the cytoplasm. The purified Nanobodies are shown to possess beneficial biochemical and biophysical properties. The crystal structure of Nanobody::antigen complexes reveal the preference of Nanobodies for cavities on the antigen surface. Thanks to the properties described above, Nanobodies became a highly valued and versatile tool for biomolecular research. Moreover, numerous diagnostic and therapeutic Nanobody-based applications have been developed in the past decade. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  5. A microprocessor-based control system for the Vienna PDS microdensitometer

    NASA Technical Reports Server (NTRS)

    Jenkner, H.; Stoll, M.; Hron, J.

    1984-01-01

    The Motorola Exorset 30 system, based on a Motorola 6809 microprocessor which serves as control processor for the microdensitometer is presented. User communication and instrument control are implemented in this syatem; data transmission to a host computer is provided via standard interfaces. The Vienna PDS system (VIPS) software was developed in BASIC and M6809 assembler. It provides efficient user interaction via function keys and argument input in a menu oriented environment. All parameters can be stored on, and retrieved from, minifloppy disks, making it possible to set up large scanning tasks. Extensive user information includes continuously updated status and coordinate displays, as well as a real time graphic display during scanning.

  6. National Apprenticeship and Training Standards for Sign, Display, and Allied Workers Industry. Revised.

    ERIC Educational Resources Information Center

    Employment and Training Administration (DOL), Washington, DC. Bureau of Apprenticeship and Training.

    These national standards are designed to provide a uniform pattern for establishing and operating effective apprenticeship programs for sign, display, and allied workers. Included in the volume are the following: provisions of the standards (definitions, qualifications for apprenticeship, selection of apprentices, terms of apprenticeship, related…

  7. A cluster analysis method for identification of subpopulations of cells in flow cytometric list-mode arrays

    NASA Technical Reports Server (NTRS)

    Li, Z. K.

    1985-01-01

    A specialized program was developed for flow cytometric list-mode data using an heirarchical tree method for identifying and enumerating individual subpopulations, the method of principal components for a two-dimensional display of 6-parameter data array, and a standard sorting algorithm for characterizing subpopulations. The program was tested against a published data set subjected to cluster analysis and experimental data sets from controlled flow cytometry experiments using a Coulter Electronics EPICS V Cell Sorter. A version of the program in compiled BASIC is usable on a 16-bit microcomputer with the MS-DOS operating system. It is specialized for 6 parameters and up to 20,000 cells. Its two-dimensional display of Euclidean distances reveals clusters clearly, as does its 1-dimensional display. The identified subpopulations can, in suitable experiments, be related to functional subpopulations of cells.

  8. Elegant Ince-Gaussian beams in a quadratic-index medium

    NASA Astrophysics Data System (ADS)

    Bai, Zhi-Yong; Deng, Dong-Mei; Guo, Qi

    2011-09-01

    Elegant Ince—Gaussian beams, which are the exact solutions of the paraxial wave equation in a quadratic-index medium, are derived in elliptical coordinates. These kinds of beams are the alternative form of standard Ince—Gaussian beams and they display better symmetry between the Ince-polynomials and the Gaussian function in mathematics. The transverse intensity distribution and the phase of the elegant Ince—Gaussian beams are discussed.

  9. Human Factors Engineering Program Review Model

    DTIC Science & Technology

    2004-02-01

    Institute, 1993). ANSI HFS-100: American National Standard for Human Factors Engineering of Visual Display Terminal Workstations (American National... American National Standard for Human Factors Engineering of Visual Display Terminal Workstations (ANSI HFS-100-1988). Santa Monica, California

  10. Volumetric depth peeling for medical image display

    NASA Astrophysics Data System (ADS)

    Borland, David; Clarke, John P.; Fielding, Julia R.; TaylorII, Russell M.

    2006-01-01

    Volumetric depth peeling (VDP) is an extension to volume rendering that enables display of otherwise occluded features in volume data sets. VDP decouples occlusion calculation from the volume rendering transfer function, enabling independent optimization of settings for rendering and occlusion. The algorithm is flexible enough to handle multiple regions occluding the object of interest, as well as object self-occlusion, and requires no pre-segmentation of the data set. VDP was developed as an improvement for virtual arthroscopy for the diagnosis of shoulder-joint trauma, and has been generalized for use in other simple and complex joints, and to enable non-invasive urology studies. In virtual arthroscopy, the surfaces in the joints often occlude each other, allowing limited viewpoints from which to evaluate these surfaces. In urology studies, the physician would like to position the virtual camera outside the kidney collecting system and see inside it. By rendering invisible all voxels between the observer's point of view and objects of interest, VDP enables viewing from unconstrained positions. In essence, VDP can be viewed as a technique for automatically defining an optimal data- and task-dependent clipping surface. Radiologists using VDP display have been able to perform evaluations of pathologies more easily and more rapidly than with clinical arthroscopy, standard volume rendering, or standard MRI/CT slice viewing.

  11. Advanced aerosense display interfaces

    NASA Astrophysics Data System (ADS)

    Hopper, Darrel G.; Meyer, Frederick M.

    1998-09-01

    High-resolution display technologies are being developed to meet the ever-increasing demand for realistic detail. The requirement for evermore visual information exceeds the capacity of fielded aerospace display interfaces. In this paper we begin an exploration of display interfaces and evolving aerospace requirements. Current and evolving standards for avionics, commercial, and flat panel displays are summarized and compared to near term goals for military and aerospace applications. Aerospace and military applications prior to 2005 up to UXGA and digital HDTV resolution can be met by using commercial interface standard developments. Advanced aerospace requirements require yet higher resolutions (2560 X 2048 color pixels, 5120 X 4096 color pixels at 85 Hz, etc.) and necessitate the initiation of discussion herein of an 'ultra digital interface standard (UDIS)' which includes 'smart interface' features such as large memory and blazingly fast resizing microcomputer. Interface capacity, IT, increased about 105 from 1973 to 1998; 102 more is needed for UDIS.

  12. Initial flight and simulator evaluation of a head up display for standard and noise abatement visual approaches

    NASA Technical Reports Server (NTRS)

    Bourquin, K.; Palmer, E. A.; Cooper, G.; Gerdes, R. M.

    1973-01-01

    A preliminary assessment was made of the adequacy of a simple head up display (HUD) for providing vertical guidance for flying noise abatement and standard visual approaches in a jet transport. The HUD featured gyro-stabilized approach angle scales which display the angle of declination to any point on the ground and a horizontal flight path bar which aids the pilot in his control of the aircraft flight path angle. Thirty-three standard and noise abatement approaches were flown in a Boeing 747 aircraft equipped with a head up display. The HUD was also simulated in a research simulator. The simulator was used to familiarize the pilots with the display and to determine the most suitable way to use the HUD for making high capture noise abatement approaches. Preliminary flight and simulator data are presented and problem areas that require further investigation are identified.

  13. 3D printing of bacteria into functional complex materials.

    PubMed

    Schaffner, Manuel; Rühs, Patrick A; Coulter, Fergal; Kilcher, Samuel; Studart, André R

    2017-12-01

    Despite recent advances to control the spatial composition and dynamic functionalities of bacteria embedded in materials, bacterial localization into complex three-dimensional (3D) geometries remains a major challenge. We demonstrate a 3D printing approach to create bacteria-derived functional materials by combining the natural diverse metabolism of bacteria with the shape design freedom of additive manufacturing. To achieve this, we embedded bacteria in a biocompatible and functionalized 3D printing ink and printed two types of "living materials" capable of degrading pollutants and of producing medically relevant bacterial cellulose. With this versatile bacteria-printing platform, complex materials displaying spatially specific compositions, geometry, and properties not accessed by standard technologies can be assembled from bottom up for new biotechnological and biomedical applications.

  14. 3D printing of bacteria into functional complex materials

    PubMed Central

    Schaffner, Manuel; Rühs, Patrick A.; Coulter, Fergal; Kilcher, Samuel; Studart, André R.

    2017-01-01

    Despite recent advances to control the spatial composition and dynamic functionalities of bacteria embedded in materials, bacterial localization into complex three-dimensional (3D) geometries remains a major challenge. We demonstrate a 3D printing approach to create bacteria-derived functional materials by combining the natural diverse metabolism of bacteria with the shape design freedom of additive manufacturing. To achieve this, we embedded bacteria in a biocompatible and functionalized 3D printing ink and printed two types of “living materials” capable of degrading pollutants and of producing medically relevant bacterial cellulose. With this versatile bacteria-printing platform, complex materials displaying spatially specific compositions, geometry, and properties not accessed by standard technologies can be assembled from bottom up for new biotechnological and biomedical applications. PMID:29214219

  15. Different Signal Enhancement Pathways of Attention and Consciousness Underlie Perception in Humans.

    PubMed

    van Boxtel, Jeroen J A

    2017-06-14

    It is not yet known whether attention and consciousness operate through similar or largely different mechanisms. Visual processing mechanisms are routinely characterized by measuring contrast response functions (CRFs). In this report, behavioral CRFs were obtained in humans (both males and females) by measuring afterimage durations over the entire range of inducer stimulus contrasts to reveal visual mechanisms behind attention and consciousness. Deviations relative to the standard CRF, i.e., gain functions, describe the strength of signal enhancement, which were assessed for both changes due to attentional task and conscious perception. It was found that attention displayed a response-gain function, whereas consciousness displayed a contrast-gain function. Through model comparisons, which only included contrast-gain modulations, both contrast-gain and response-gain effects can be explained with a two-level normalization model, in which consciousness affects only the first level and attention affects only the second level. These results demonstrate that attention and consciousness can effectively show different gain functions because they operate through different signal enhancement mechanisms. SIGNIFICANCE STATEMENT The relationship between attention and consciousness is still debated. Mapping contrast response functions (CRFs) has allowed (neuro)scientists to gain important insights into the mechanistic underpinnings of visual processing. Here, the influence of both attention and consciousness on these functions were measured and they displayed a strong dissociation. First, attention lowered CRFs, whereas consciousness raised them. Second, attention manifests itself as a response-gain function, whereas consciousness manifests itself as a contrast-gain function. Extensive model comparisons show that these results are best explained in a two-level normalization model in which consciousness affects only the first level, whereas attention affects only the second level. These findings show dissociations between both the computational mechanisms behind attention and consciousness and the perceptual consequences that they induce. Copyright © 2017 the authors 0270-6474/17/375912-11$15.00/0.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Panek, R.L.; Dixon, W.R.; Rutledge, C.O.

    The effect of dietary lipid treatment on sympathetic neuronal function was examined in isolated perfused tail arteries of adult rats. The hypothesis that dietary manipulations alter the lipid environment of receptor proteins which may result in the perturbation of specific membrane-associated processes that regulate peripheral adrenergic neurotransmission in the vasculature was the basis for this investigation. In the present study, rats were fed semisynthetic diets enriched in either 16% coconut oil (saturated fat) or 16% sunflower oil (unsaturated fat). The field stimulation-evoked release of endogenous norepinephrine and total /sup 3/H was decreased significantly in rats receiving the coconut oil dietmore » when compared to either sunflower oil- or standard lab chow-fed rats. Norepinephrine content in artery segments from coconut oil-treated rats was significantly higher compared to either sunflower oil- or standard lab chow-fed rats. Tail arteries from rats receiving the coconut oil diet displayed significantly lower perfusion pressure responses to nerve stimulation at all frequencies tested when compared to the sunflower oil- or standard lab chow-fed rats. Vasoconstrictor responses of perfused tail arteries exposed to exogenous norepinephrine resulted in an EC50 for norepinephrine that was not changed by the dietary treatment, but adult rats receiving the sunflower oil diet displayed a significantly greater maximum response to exogenous norepinephrine (10(-5) M) compared to arteries from either coconut oil- or standard lab chow-fed rats.« less

  17. Color standardization and optimization in whole slide imaging.

    PubMed

    Yagi, Yukako

    2011-03-30

    Standardization and validation of the color displayed by digital slides is an important aspect of digital pathology implementation. While the most common reason for color variation is the variance in the protocols and practices in the histology lab, the color displayed can also be affected by variation in capture parameters (for example, illumination and filters), image processing and display factors in the digital systems themselves. We have been developing techniques for color validation and optimization along two paths. The first was based on two standard slides that are scanned and displayed by the imaging system in question. In this approach, one slide is embedded with nine filters with colors selected especially for H&E stained slides (looking like tiny Macbeth color chart); the specific color of the nine filters were determined in our previous study and modified for whole slide imaging (WSI). The other slide is an H&E stained mouse embryo. Both of these slides were scanned and the displayed images were compared to a standard. The second approach was based on our previous multispectral imaging research. As a first step, the two slide method (above) was used to identify inaccurate display of color and its cause, and to understand the importance of accurate color in digital pathology. We have also improved the multispectral-based algorithm for more consistent results in stain standardization. In near future, the results of the two slide and multispectral techniques can be combined and will be widely available. We have been conducting a series of researches and developing projects to improve image quality to establish Image Quality Standardization. This paper discusses one of most important aspects of image quality - color.

  18. Effect of Harm Anchors in Visual Displays of Test Results on Patient Perceptions of Urgency About Near-Normal Values: Experimental Study.

    PubMed

    Zikmund-Fisher, Brian J; Scherer, Aaron M; Witteman, Holly O; Solomon, Jacob B; Exe, Nicole L; Fagerlin, Angela

    2018-03-26

    Patient-facing displays of laboratory test results typically provide patients with one reference point (the "standard range"). To test the effect of including an additional harm anchor reference point in visual displays of laboratory test results, which indicates how far outside of the standard range values would need to be in order to suggest substantial patient risk. Using a demographically diverse, online sample, we compared the reactions of 1618 adults in the United States who viewed visual line displays that included both standard range and harm anchor reference points ("Many doctors are not concerned until here") to displays that included either (1) only a standard range, (2) standard range plus evaluative categories (eg, "borderline high"), or (3) a color gradient showing degree of deviation from the standard range. Providing the harm anchor reference point significantly reduced perceived urgency of close-to-normal alanine aminotransferase and creatinine results (P values <.001) but not generally for platelet count results. Notably, display type did not significantly alter perceptions of more extreme results in potentially harmful ranges. Harm anchors also substantially reduced the number of participants who wanted to contact their doctor urgently or go to the hospital about these test results. Presenting patients with evaluative cues regarding when test results become clinically concerning can reduce the perceived urgency of out-of-range results that do not require immediate clinical action. ©Brian J Zikmund-Fisher, Aaron M Scherer, Holly O Witteman, Jacob B Solomon, Nicole L Exe, Angela Fagerlin. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 26.03.2018.

  19. A deviation display method for visualising data in mobile gamma-ray spectrometry.

    PubMed

    Kock, Peder; Finck, Robert R; Nilsson, Jonas M C; Ostlund, Karl; Samuelsson, Christer

    2010-09-01

    A real time visualisation method, to be used in mobile gamma-spectrometric search operations using standard detector systems is presented. The new method, called deviation display, uses a modified waterfall display to present relative changes in spectral data over energy and time. Using unshielded (137)Cs and (241)Am point sources and different natural background environments, the behaviour of the deviation displays is demonstrated and analysed for two standard detector types (NaI(Tl) and HPGe). The deviation display enhances positive significant changes while suppressing the natural background fluctuations. After an initialization time of about 10min this technique leads to a homogeneous display dominated by the background colour, where even small changes in spectral data are easy to discover. As this paper shows, the deviation display method works well for all tested gamma energies and natural background radiation levels and with both tested detector systems.

  20. Display formats manual

    NASA Technical Reports Server (NTRS)

    Runnels, R. L.

    1973-01-01

    The standards and procedures for the generation of operational display formats to be used in the Mission Control Center (MCC) display control system are presented. The required effort, forms, and fundamentals for the design, specifications, and production of display formats are identified. The principles of display design and system constraints controlling the creation of optimum operational displays for mission control are explained. The basic two types of MCC display systems for presenting information are described.

  1. Entanglement of 3000 atoms by detecting one photon

    NASA Astrophysics Data System (ADS)

    Vuletic, Vladan

    2016-05-01

    Quantum-mechanically correlated (entangled) states of many particles are of interest in quantum information, quantum computing and quantum metrology. In particular, entangled states of many particles can be used to overcome limits on measurements performed with ensembles of independent atoms (standard quantum limit). Metrologically useful entangled states of large atomic ensembles (spin squeezed states) have been experimentally realized. These states display Gaussian spin distribution functions with a non-negative Wigner quasiprobability distribution function. We report the generation of entanglement in a large atomic ensemble via an interaction with a very weak laser pulse; remarkably, the detection of a single photon prepares several thousand atoms in an entangled state. We reconstruct a negative-valued Wigner function, and verify an entanglement depth (the minimum number of mutually entangled atoms) that comprises 90% of the atomic ensemble containing 3100 atoms. Further technical improvement should allow the generation of more complex Schrödinger cat states, and of states the overcome the standard quantum limit.

  2. Nonlinear mapping of the luminance in dual-layer high dynamic range displays

    NASA Astrophysics Data System (ADS)

    Guarnieri, Gabriele; Ramponi, Giovanni; Bonfiglio, Silvio; Albani, Luigi

    2009-02-01

    It has long been known that the human visual system (HVS) has a nonlinear response to luminance. This nonlinearity can be quantified using the concept of just noticeable difference (JND), which represents the minimum amplitude of a specified test pattern an average observer can discern from a uniform background. The JND depends on the background luminance following a threshold versus intensity (TVI) function. It is possible to define a curve which maps physical luminances into a perceptually linearized domain. This mapping can be used to optimize a digital encoding, by minimizing the visibility of quantization noise. It is also commonly used in medical applications to display images adapting to the characteristics of the display device. High dynamic range (HDR) displays, which are beginning to appear on the market, can display luminance levels outside the range in which most standard mapping curves are defined. In particular, dual-layer LCD displays are able to extend the gamut of luminance offered by conventional liquid crystals towards the black region; in such areas suitable and HVS-compliant luminance transformations need to be determined. In this paper we propose a method, which is primarily targeted to the extension of the DICOM curve used in medical imaging, but also has a more general application. The method can be modified in order to compensate for the ambient light, which can be significantly greater than the black level of an HDR display and consequently reduce the visibility of the details in dark areas.

  3. Does Contextual Cueing Guide the Deployment of Attention?

    PubMed Central

    Kunar, Melina A.; Flusberg, Stephen; Horowitz, Todd S.; Wolfe, Jeremy M.

    2008-01-01

    Contextual cueing experiments show that when displays are repeated, reaction times (RTs) to find a target decrease over time even when observers are not aware of the repetition. It has been thought that the context of the display guides attention to the target. We tested this hypothesis by comparing the effects of guidance in a standard search task to the effects of contextual cueing. Firstly, in standard search, an improvement in guidance causes search slopes (derived from RT × Set Size functions) to decrease. In contrast, we found that search slopes in contextual cueing did not become more efficient over time (Experiment 1). Secondly, when guidance is optimal (e.g. in easy feature search) we still found a small, but reliable contextual cueing effect (Experiments 2a and 2b), suggesting that other factors, such as response selection, contribute to the effect. Experiment 3 supported this hypothesis by showing that the contextual cueing effect disappeared when we added interference to the response selection process. Overall, our data suggest that the relationship between guidance and contextual cueing is weak and that response selection can account for part of the effect. PMID:17683230

  4. A Study of the Effects of Material Type and Configuration on Optical Cross Section

    DTIC Science & Technology

    2012-09-01

    a whole. In order to understand these optical signatures, a means to accurately measure, model , and simulate the space objects is necessary. The space...subject to a penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. 1. REPORT...THIS PAGE unclassified Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 as Bidrectional Reflectivity Distribution Function ( BRDF ) can

  5. Reliable cloning of functional antibody variable domains from hybridomas and spleen cell repertoires employing a reengineered phage display system.

    PubMed

    Krebber, A; Bornhauser, S; Burmester, J; Honegger, A; Willuda, J; Bosshard, H R; Plückthun, A

    1997-02-14

    A prerequisite for the use of recombinant antibody technologies starting from hybridomas or immune repertoires is the reliable cloning of functional immunoglobulin genes. For this purpose, a standard phage display system was optimized for robustness, vector stability, tight control of scFv-delta geneIII expression, primer usage for PCR amplification of variable region genes, scFv assembly strategy and subsequent directional cloning using a single rare cutting restriction enzyme. This integrated cloning, screening and selection system allowed us to rapidly obtain antigen binding scFvs derived from spleen-cell repertoires of mice immunized with ampicillin as well as from all hybridoma cell lines tested to date. As representative examples, cloning of monoclonal antibodies against a his tag, leucine zippers, the tumor marker EGP-2 and the insecticide DDT is presented. Several hybridomas whose genes could not be cloned in previous experimental setups, but were successfully obtained with the present system, expressed high amounts of aberrant heavy and light chain mRNAs, which were amplified by PCR and greatly exceeded the amount of binding antibody sequences. These contaminating variable region genes were successfully eliminated by employing the optimized phage display system, thus avoiding time consuming sequencing of non-binding scFv genes. To maximize soluble expression of functional scFvs subsequent to cloning, a compatible vector series to simplify modification, detection, multimerization and rapid purification of recombinant antibody fragments was constructed.

  6. Integrated software environment based on COMKAT for analyzing tracer pharmacokinetics with molecular imaging.

    PubMed

    Fang, Yu-Hua Dean; Asthana, Pravesh; Salinas, Cristian; Huang, Hsuan-Ming; Muzic, Raymond F

    2010-01-01

    An integrated software package, Compartment Model Kinetic Analysis Tool (COMKAT), is presented in this report. COMKAT is an open-source software package with many functions for incorporating pharmacokinetic analysis in molecular imaging research and has both command-line and graphical user interfaces. With COMKAT, users may load and display images, draw regions of interest, load input functions, select kinetic models from a predefined list, or create a novel model and perform parameter estimation, all without having to write any computer code. For image analysis, COMKAT image tool supports multiple image file formats, including the Digital Imaging and Communications in Medicine (DICOM) standard. Image contrast, zoom, reslicing, display color table, and frame summation can be adjusted in COMKAT image tool. It also displays and automatically registers images from 2 modalities. Parametric imaging capability is provided and can be combined with the distributed computing support to enhance computation speeds. For users without MATLAB licenses, a compiled, executable version of COMKAT is available, although it currently has only a subset of the full COMKAT capability. Both the compiled and the noncompiled versions of COMKAT are free for academic research use. Extensive documentation, examples, and COMKAT itself are available on its wiki-based Web site, http://comkat.case.edu. Users are encouraged to contribute, sharing their experience, examples, and extensions of COMKAT. With integrated functionality specifically designed for imaging and kinetic modeling analysis, COMKAT can be used as a software environment for molecular imaging and pharmacokinetic analysis.

  7. Scaling theory of temporal correlations and size-dependent fluctuations in the traded value of stocks

    NASA Astrophysics Data System (ADS)

    Eisler, Zoltán; Kertész, János

    2006-04-01

    Records of the traded value fi of stocks display fluctuation scaling, a proportionality between the standard deviation σi and the average ⟨fi⟩ : σi∝⟨fi⟩α , with a strong time scale dependence α(Δt) . The nontrivial (i.e., neither 0.5 nor 1) value of α may have different origins and provides information about the microscopic dynamics. We present a set of stylized facts and then show their connection to such behavior. The functional form α(Δt) originates from two aspects of the dynamics: Stocks of larger companies both tend to be traded in larger packages and also display stronger correlations of traded value. The results are integrated into a general framework that can be applied to a wide range of complex systems.

  8. Standardization versus customization of glucose reporting.

    PubMed

    Rodbard, David

    2013-05-01

    Bergenstal et al. (Diabetes Technol Ther 2013;15:198-211) described an important approach toward standardization of reporting and analysis of continuous glucose monitoring and self-monitoring of blood glucose (SMBG) data. The ambulatory glucose profile (AGP), a composite display of glucose by time of day that superimposes data from multiple days, is perhaps the most informative and useful of the many graphical approaches to display glucose data. However, the AGP has limitations; some variations are desirable and useful. Synchronization with respect to meals, traditionally used in glucose profiles for SMBG data, can improve characterization of postprandial glucose excursions. Several other types of graphical display are available, and recently developed ones can augment the information provided by the AGP. There is a need to standardize the parameters describing glycemic variability and cross-validate the available computer programs that calculate glycemic variability. Clinical decision support software can identify and prioritize clinical problems, make recommendations for modifications of therapy, and explain its justification for those recommendations. The goal of standardization is challenging in view of the diversity of clinical situations and of computing and display platforms and software. Standardization is desirable but must be done in a manner that permits flexibility and fosters innovation.

  9. ELAS - SCIENCE & TECHNOLOGY LABORATORY APPLICATIONS SOFTWARE (SILICON GRAPHICS VERSION)

    NASA Technical Reports Server (NTRS)

    Walters, D.

    1994-01-01

    The Science and Technology Laboratory Applications Software (ELAS) was originally designed to analyze and process digital imagery data, specifically remotely-sensed scanner data. This capability includes the processing of Landsat multispectral data; aircraft-acquired scanner data; digitized topographic data; and numerous other ancillary data, such as soil types and rainfall information, that can be stored in digitized form. ELAS has the subsequent capability to geographically reference this data to dozens of standard, as well as user created projections. As an integrated image processing system, ELAS offers the user of remotely-sensed data a wide range of capabilities in the areas of land cover analysis and general purpose image analysis. ELAS is designed for flexible use and operation and includes its own FORTRAN operating subsystem and an expandable set of FORTRAN application modules. Because all of ELAS resides in one "logical" FORTRAN program, data inputs and outputs, directives, and module switching are convenient for the user. There are over 230 modules presently available to aid the user in performing a wide range of land cover analyses and manipulation. The file management modules enable the user to allocate, define, access, and specify usage for all types of files (ELAS files, subfiles, external files etc.). Various other modules convert specific types of satellite, aircraft, and vector-polygon data into files that can be used by other ELAS modules. The user also has many module options which aid in displaying image data, such as magnification/reduction of the display; true color display; and several memory functions. Additional modules allow for the building and manipulation of polygonal areas of the image data. Finally, there are modules which allow the user to select and classify the image data. An important feature of the ELAS subsystem is that its structure allows new applications modules to be easily integrated in the future. ELAS has as a standard the flexibility to process data elements exceeding 8 bits in length, including floating point (noninteger) elements and 16 or 32 bit integers. Thus it is able to analyze and process "non-standard" nonimage data. The VAX (ERL-10017) and Concurrent (ERL-10013) versions of ELAS 9.0 are written in FORTRAN and ASSEMBLER for DEC VAX series computers running VMS and Concurrent computers running MTM. The Sun (SSC-00019), Masscomp (SSC-00020), and Silicon Graphics (SSC-00021) versions of ELAS 9.0 are written in FORTRAN 77 and C-LANGUAGE for Sun4 series computers running SunOS, Masscomp computers running UNIX, and Silicon Graphics IRIS computers running IRIX. The Concurrent version requires at least 15 bit addressing and a direct memory access channel. The VAX and Concurrent versions of ELAS both require floating-point hardware, at least 1Mb of RAM, and approximately 70Mb of disk space. Both versions also require a COMTAL display device in order to display images. For the Sun, Masscomp, and Silicon Graphics versions of ELAS, the disk storage required is approximately 115Mb, and a minimum of 8Mb of RAM is required for execution. The Sun version of ELAS requires either the X-Window System Version 11 Revision 4 or Sun OpenWindows Version 2. The Masscomp version requires a GA1000 display device and the associated "gp" library. The Silicon Graphics version requires Silicon Graphics' GL library. ELAS display functions will not work with a monochrome monitor. The standard distribution medium for the VAX version (ERL10017) is a set of two 9-track 1600 BPI magnetic tapes in DEC VAX BACKUP format. This version is also available on a TK50 tape cartridge in DEC VAX BACKUP format. The standard distribution medium for the Concurrent version (ERL-10013) is a set of two 9-track 1600 BPI magnetic tapes in Concurrent BACKUP format. The standard distribution medium for the Sun version (SSC-00019) is a .25 inch streaming magnetic tape cartridge in UNIX tar format. The standard distribution medium for the Masscomp version, (SSC-00020) is a .25 inch streaming magnetic tape cartridge in UNIX tar format. The standard distribution medium for the Silicon Graphics version (SSC-00021) is a .25 inch streaming magnetic IRIS tape cartridge in UNIX tar format. Version 9.0 was released in 1991. Sun4, SunOS, and Open Windows are trademarks of Sun Microsystems, Inc. MIT X Window System is licensed by Massachusetts Institute of Technology.

  10. ELAS - SCIENCE & TECHNOLOGY LABORATORY APPLICATIONS SOFTWARE (CONCURRENT VERSION)

    NASA Technical Reports Server (NTRS)

    Pearson, R. W.

    1994-01-01

    The Science and Technology Laboratory Applications Software (ELAS) was originally designed to analyze and process digital imagery data, specifically remotely-sensed scanner data. This capability includes the processing of Landsat multispectral data; aircraft-acquired scanner data; digitized topographic data; and numerous other ancillary data, such as soil types and rainfall information, that can be stored in digitized form. ELAS has the subsequent capability to geographically reference this data to dozens of standard, as well as user created projections. As an integrated image processing system, ELAS offers the user of remotely-sensed data a wide range of capabilities in the areas of land cover analysis and general purpose image analysis. ELAS is designed for flexible use and operation and includes its own FORTRAN operating subsystem and an expandable set of FORTRAN application modules. Because all of ELAS resides in one "logical" FORTRAN program, data inputs and outputs, directives, and module switching are convenient for the user. There are over 230 modules presently available to aid the user in performing a wide range of land cover analyses and manipulation. The file management modules enable the user to allocate, define, access, and specify usage for all types of files (ELAS files, subfiles, external files etc.). Various other modules convert specific types of satellite, aircraft, and vector-polygon data into files that can be used by other ELAS modules. The user also has many module options which aid in displaying image data, such as magnification/reduction of the display; true color display; and several memory functions. Additional modules allow for the building and manipulation of polygonal areas of the image data. Finally, there are modules which allow the user to select and classify the image data. An important feature of the ELAS subsystem is that its structure allows new applications modules to be easily integrated in the future. ELAS has as a standard the flexibility to process data elements exceeding 8 bits in length, including floating point (noninteger) elements and 16 or 32 bit integers. Thus it is able to analyze and process "non-standard" nonimage data. The VAX (ERL-10017) and Concurrent (ERL-10013) versions of ELAS 9.0 are written in FORTRAN and ASSEMBLER for DEC VAX series computers running VMS and Concurrent computers running MTM. The Sun (SSC-00019), Masscomp (SSC-00020), and Silicon Graphics (SSC-00021) versions of ELAS 9.0 are written in FORTRAN 77 and C-LANGUAGE for Sun4 series computers running SunOS, Masscomp computers running UNIX, and Silicon Graphics IRIS computers running IRIX. The Concurrent version requires at least 15 bit addressing and a direct memory access channel. The VAX and Concurrent versions of ELAS both require floating-point hardware, at least 1Mb of RAM, and approximately 70Mb of disk space. Both versions also require a COMTAL display device in order to display images. For the Sun, Masscomp, and Silicon Graphics versions of ELAS, the disk storage required is approximately 115Mb, and a minimum of 8Mb of RAM is required for execution. The Sun version of ELAS requires either the X-Window System Version 11 Revision 4 or Sun OpenWindows Version 2. The Masscomp version requires a GA1000 display device and the associated "gp" library. The Silicon Graphics version requires Silicon Graphics' GL library. ELAS display functions will not work with a monochrome monitor. The standard distribution medium for the VAX version (ERL10017) is a set of two 9-track 1600 BPI magnetic tapes in DEC VAX BACKUP format. This version is also available on a TK50 tape cartridge in DEC VAX BACKUP format. The standard distribution medium for the Concurrent version (ERL-10013) is a set of two 9-track 1600 BPI magnetic tapes in Concurrent BACKUP format. The standard distribution medium for the Sun version (SSC-00019) is a .25 inch streaming magnetic tape cartridge in UNIX tar format. The standard distribution medium for the Masscomp version, (SSC-00020) is a .25 inch streaming magnetic tape cartridge in UNIX tar format. The standard distribution medium for the Silicon Graphics version (SSC-00021) is a .25 inch streaming magnetic IRIS tape cartridge in UNIX tar format. Version 9.0 was released in 1991. Sun4, SunOS, and Open Windows are trademarks of Sun Microsystems, Inc. MIT X Window System is licensed by Massachusetts Institute of Technology.

  11. ELAS - SCIENCE & TECHNOLOGY LABORATORY APPLICATIONS SOFTWARE (SUN VERSION)

    NASA Technical Reports Server (NTRS)

    Walters, D.

    1994-01-01

    The Science and Technology Laboratory Applications Software (ELAS) was originally designed to analyze and process digital imagery data, specifically remotely-sensed scanner data. This capability includes the processing of Landsat multispectral data; aircraft-acquired scanner data; digitized topographic data; and numerous other ancillary data, such as soil types and rainfall information, that can be stored in digitized form. ELAS has the subsequent capability to geographically reference this data to dozens of standard, as well as user created projections. As an integrated image processing system, ELAS offers the user of remotely-sensed data a wide range of capabilities in the areas of land cover analysis and general purpose image analysis. ELAS is designed for flexible use and operation and includes its own FORTRAN operating subsystem and an expandable set of FORTRAN application modules. Because all of ELAS resides in one "logical" FORTRAN program, data inputs and outputs, directives, and module switching are convenient for the user. There are over 230 modules presently available to aid the user in performing a wide range of land cover analyses and manipulation. The file management modules enable the user to allocate, define, access, and specify usage for all types of files (ELAS files, subfiles, external files etc.). Various other modules convert specific types of satellite, aircraft, and vector-polygon data into files that can be used by other ELAS modules. The user also has many module options which aid in displaying image data, such as magnification/reduction of the display; true color display; and several memory functions. Additional modules allow for the building and manipulation of polygonal areas of the image data. Finally, there are modules which allow the user to select and classify the image data. An important feature of the ELAS subsystem is that its structure allows new applications modules to be easily integrated in the future. ELAS has as a standard the flexibility to process data elements exceeding 8 bits in length, including floating point (noninteger) elements and 16 or 32 bit integers. Thus it is able to analyze and process "non-standard" nonimage data. The VAX (ERL-10017) and Concurrent (ERL-10013) versions of ELAS 9.0 are written in FORTRAN and ASSEMBLER for DEC VAX series computers running VMS and Concurrent computers running MTM. The Sun (SSC-00019), Masscomp (SSC-00020), and Silicon Graphics (SSC-00021) versions of ELAS 9.0 are written in FORTRAN 77 and C-LANGUAGE for Sun4 series computers running SunOS, Masscomp computers running UNIX, and Silicon Graphics IRIS computers running IRIX. The Concurrent version requires at least 15 bit addressing and a direct memory access channel. The VAX and Concurrent versions of ELAS both require floating-point hardware, at least 1Mb of RAM, and approximately 70Mb of disk space. Both versions also require a COMTAL display device in order to display images. For the Sun, Masscomp, and Silicon Graphics versions of ELAS, the disk storage required is approximately 115Mb, and a minimum of 8Mb of RAM is required for execution. The Sun version of ELAS requires either the X-Window System Version 11 Revision 4 or Sun OpenWindows Version 2. The Masscomp version requires a GA1000 display device and the associated "gp" library. The Silicon Graphics version requires Silicon Graphics' GL library. ELAS display functions will not work with a monochrome monitor. The standard distribution medium for the VAX version (ERL10017) is a set of two 9-track 1600 BPI magnetic tapes in DEC VAX BACKUP format. This version is also available on a TK50 tape cartridge in DEC VAX BACKUP format. The standard distribution medium for the Concurrent version (ERL-10013) is a set of two 9-track 1600 BPI magnetic tapes in Concurrent BACKUP format. The standard distribution medium for the Sun version (SSC-00019) is a .25 inch streaming magnetic tape cartridge in UNIX tar format. The standard distribution medium for the Masscomp version, (SSC-00020) is a .25 inch streaming magnetic tape cartridge in UNIX tar format. The standard distribution medium for the Silicon Graphics version (SSC-00021) is a .25 inch streaming magnetic IRIS tape cartridge in UNIX tar format. Version 9.0 was released in 1991. Sun4, SunOS, and Open Windows are trademarks of Sun Microsystems, Inc. MIT X Window System is licensed by Massachusetts Institute of Technology.

  12. ELAS - SCIENCE & TECHNOLOGY LABORATORY APPLICATIONS SOFTWARE (MASSCOMP VERSION)

    NASA Technical Reports Server (NTRS)

    Walters, D.

    1994-01-01

    The Science and Technology Laboratory Applications Software (ELAS) was originally designed to analyze and process digital imagery data, specifically remotely-sensed scanner data. This capability includes the processing of Landsat multispectral data; aircraft-acquired scanner data; digitized topographic data; and numerous other ancillary data, such as soil types and rainfall information, that can be stored in digitized form. ELAS has the subsequent capability to geographically reference this data to dozens of standard, as well as user created projections. As an integrated image processing system, ELAS offers the user of remotely-sensed data a wide range of capabilities in the areas of land cover analysis and general purpose image analysis. ELAS is designed for flexible use and operation and includes its own FORTRAN operating subsystem and an expandable set of FORTRAN application modules. Because all of ELAS resides in one "logical" FORTRAN program, data inputs and outputs, directives, and module switching are convenient for the user. There are over 230 modules presently available to aid the user in performing a wide range of land cover analyses and manipulation. The file management modules enable the user to allocate, define, access, and specify usage for all types of files (ELAS files, subfiles, external files etc.). Various other modules convert specific types of satellite, aircraft, and vector-polygon data into files that can be used by other ELAS modules. The user also has many module options which aid in displaying image data, such as magnification/reduction of the display; true color display; and several memory functions. Additional modules allow for the building and manipulation of polygonal areas of the image data. Finally, there are modules which allow the user to select and classify the image data. An important feature of the ELAS subsystem is that its structure allows new applications modules to be easily integrated in the future. ELAS has as a standard the flexibility to process data elements exceeding 8 bits in length, including floating point (noninteger) elements and 16 or 32 bit integers. Thus it is able to analyze and process "non-standard" nonimage data. The VAX (ERL-10017) and Concurrent (ERL-10013) versions of ELAS 9.0 are written in FORTRAN and ASSEMBLER for DEC VAX series computers running VMS and Concurrent computers running MTM. The Sun (SSC-00019), Masscomp (SSC-00020), and Silicon Graphics (SSC-00021) versions of ELAS 9.0 are written in FORTRAN 77 and C-LANGUAGE for Sun4 series computers running SunOS, Masscomp computers running UNIX, and Silicon Graphics IRIS computers running IRIX. The Concurrent version requires at least 15 bit addressing and a direct memory access channel. The VAX and Concurrent versions of ELAS both require floating-point hardware, at least 1Mb of RAM, and approximately 70Mb of disk space. Both versions also require a COMTAL display device in order to display images. For the Sun, Masscomp, and Silicon Graphics versions of ELAS, the disk storage required is approximately 115Mb, and a minimum of 8Mb of RAM is required for execution. The Sun version of ELAS requires either the X-Window System Version 11 Revision 4 or Sun OpenWindows Version 2. The Masscomp version requires a GA1000 display device and the associated "gp" library. The Silicon Graphics version requires Silicon Graphics' GL library. ELAS display functions will not work with a monochrome monitor. The standard distribution medium for the VAX version (ERL10017) is a set of two 9-track 1600 BPI magnetic tapes in DEC VAX BACKUP format. This version is also available on a TK50 tape cartridge in DEC VAX BACKUP format. The standard distribution medium for the Concurrent version (ERL-10013) is a set of two 9-track 1600 BPI magnetic tapes in Concurrent BACKUP format. The standard distribution medium for the Sun version (SSC-00019) is a .25 inch streaming magnetic tape cartridge in UNIX tar format. The standard distribution medium for the Masscomp version, (SSC-00020) is a .25 inch streaming magnetic tape cartridge in UNIX tar format. The standard distribution medium for the Silicon Graphics version (SSC-00021) is a .25 inch streaming magnetic IRIS tape cartridge in UNIX tar format. Version 9.0 was released in 1991. Sun4, SunOS, and Open Windows are trademarks of Sun Microsystems, Inc. MIT X Window System is licensed by Massachusetts Institute of Technology.

  13. ELAS - SCIENCE & TECHNOLOGY LABORATORY APPLICATIONS SOFTWARE (DEC VAX VERSION)

    NASA Technical Reports Server (NTRS)

    Junkin, B. G.

    1994-01-01

    The Science and Technology Laboratory Applications Software (ELAS) was originally designed to analyze and process digital imagery data, specifically remotely-sensed scanner data. This capability includes the processing of Landsat multispectral data; aircraft-acquired scanner data; digitized topographic data; and numerous other ancillary data, such as soil types and rainfall information, that can be stored in digitized form. ELAS has the subsequent capability to geographically reference this data to dozens of standard, as well as user created projections. As an integrated image processing system, ELAS offers the user of remotely-sensed data a wide range of capabilities in the areas of land cover analysis and general purpose image analysis. ELAS is designed for flexible use and operation and includes its own FORTRAN operating subsystem and an expandable set of FORTRAN application modules. Because all of ELAS resides in one "logical" FORTRAN program, data inputs and outputs, directives, and module switching are convenient for the user. There are over 230 modules presently available to aid the user in performing a wide range of land cover analyses and manipulation. The file management modules enable the user to allocate, define, access, and specify usage for all types of files (ELAS files, subfiles, external files etc.). Various other modules convert specific types of satellite, aircraft, and vector-polygon data into files that can be used by other ELAS modules. The user also has many module options which aid in displaying image data, such as magnification/reduction of the display; true color display; and several memory functions. Additional modules allow for the building and manipulation of polygonal areas of the image data. Finally, there are modules which allow the user to select and classify the image data. An important feature of the ELAS subsystem is that its structure allows new applications modules to be easily integrated in the future. ELAS has as a standard the flexibility to process data elements exceeding 8 bits in length, including floating point (noninteger) elements and 16 or 32 bit integers. Thus it is able to analyze and process "non-standard" nonimage data. The VAX (ERL-10017) and Concurrent (ERL-10013) versions of ELAS 9.0 are written in FORTRAN and ASSEMBLER for DEC VAX series computers running VMS and Concurrent computers running MTM. The Sun (SSC-00019), Masscomp (SSC-00020), and Silicon Graphics (SSC-00021) versions of ELAS 9.0 are written in FORTRAN 77 and C-LANGUAGE for Sun4 series computers running SunOS, Masscomp computers running UNIX, and Silicon Graphics IRIS computers running IRIX. The Concurrent version requires at least 15 bit addressing and a direct memory access channel. The VAX and Concurrent versions of ELAS both require floating-point hardware, at least 1Mb of RAM, and approximately 70Mb of disk space. Both versions also require a COMTAL display device in order to display images. For the Sun, Masscomp, and Silicon Graphics versions of ELAS, the disk storage required is approximately 115Mb, and a minimum of 8Mb of RAM is required for execution. The Sun version of ELAS requires either the X-Window System Version 11 Revision 4 or Sun OpenWindows Version 2. The Masscomp version requires a GA1000 display device and the associated "gp" library. The Silicon Graphics version requires Silicon Graphics' GL library. ELAS display functions will not work with a monochrome monitor. The standard distribution medium for the VAX version (ERL10017) is a set of two 9-track 1600 BPI magnetic tapes in DEC VAX BACKUP format. This version is also available on a TK50 tape cartridge in DEC VAX BACKUP format. The standard distribution medium for the Concurrent version (ERL-10013) is a set of two 9-track 1600 BPI magnetic tapes in Concurrent BACKUP format. The standard distribution medium for the Sun version (SSC-00019) is a .25 inch streaming magnetic tape cartridge in UNIX tar format. The standard distribution medium for the Masscomp version, (SSC-00020) is a .25 inch streaming magnetic tape cartridge in UNIX tar format. The standard distribution medium for the Silicon Graphics version (SSC-00021) is a .25 inch streaming magnetic IRIS tape cartridge in UNIX tar format. Version 9.0 was released in 1991. Sun4, SunOS, and Open Windows are trademarks of Sun Microsystems, Inc. MIT X Window System is licensed by Massachusetts Institute of Technology.

  14. Microgap flat panel display

    DOEpatents

    Wuest, C.R.

    1998-12-08

    A microgap flat panel display is disclosed which includes a thin gas-filled display tube that utilizes switched X-Y ``pixel`` strips to trigger electron avalanches and activate a phosphor at a given location on a display screen. The panel utilizes the principal of electron multiplication in a gas subjected to a high electric field to provide sufficient electron current to activate standard luminescent phosphors located on an anode. The X-Y conductive strips of a few micron widths may for example, be deposited on opposite sides of a thin insulating substrate, or on one side of the adjacent substrates and function as a cathode. The X-Y strips are separated from the anode by a gap filled with a suitable gas. Electrical bias is selectively switched onto X and Y strips to activate a ``pixel`` in the region where these strips overlap. A small amount of a long-lived radioisotope is used to initiate an electron avalanche in the overlap region when bias is applied. The avalanche travels through the gas filled gap and activates a luminescent phosphor of a selected color. The bias is adjusted to give a proportional electron multiplication to control brightness for given pixel. 6 figs.

  15. Probability of the moiré effect in barrier and lenticular autostereoscopic 3D displays.

    PubMed

    Saveljev, Vladimir; Kim, Sung-Kyu

    2015-10-05

    The probability of the moiré effect in LCD displays is estimated as a function of angle based on the experimental data; a theoretical function (node spacing) is proposed basing on the distance between nodes. Both functions are close to each other. The connection between the probability of the moiré effect and the Thomae's function is also found. The function proposed in this paper can be used in the minimization of the moiré effect in visual displays, especially in autostereoscopic 3D displays.

  16. Environmental Control Subsystem Development

    NASA Technical Reports Server (NTRS)

    Laidlaw, Jacob; Zelik, Jonathan

    2017-01-01

    Kennedy Space Center's Launch Pad 39B, part of Launch Complex 39, is currently undergoing construction to prepare it for NASA's Space Launch System missions. The Environmental Control Subsystem, which provides the vehicle with an air or nitrogen gas environment, required development of its local and remote display screens. The remote displays, developed by NASA contractors and previous interns, were developed without complete functionality; the remote displays were revised, adding functionality to over 90 displays. For the local displays, multiple test procedures were developed to assess the functionality of the screens, as well as verify requirements. One local display screen was also developed.

  17. Comparative Study of the MTFA, ICS, and SQRI Image Quality Metrics for Visual Display Systems

    DTIC Science & Technology

    1991-09-01

    reasonable image quality predictions across select display and viewing condition parameters. 101 6.0 REFERENCES American National Standard for Human Factors Engineering of ’ Visual Display Terminal Workstations . ANSI

  18. GenASiS Basics: Object-oriented utilitarian functionality for large-scale physics simulations

    DOE PAGES

    Cardall, Christian Y.; Budiardja, Reuben D.

    2015-06-11

    Aside from numerical algorithms and problem setup, large-scale physics simulations on distributed-memory supercomputers require more basic utilitarian functionality, such as physical units and constants; display to the screen or standard output device; message passing; I/O to disk; and runtime parameter management and usage statistics. Here we describe and make available Fortran 2003 classes furnishing extensible object-oriented implementations of this sort of rudimentary functionality, along with individual `unit test' programs and larger example problems demonstrating their use. Lastly, these classes compose the Basics division of our developing astrophysics simulation code GenASiS (General Astrophysical Simulation System), but their fundamental nature makes themmore » useful for physics simulations in many fields.« less

  19. Reexamination of color vision standards, part I : status of color use in ATC displays and demography of color-deficit controllers : final report.

    DOT National Transportation Integrated Search

    2006-02-01

    This report describes the status of color use in current air traffic control (ATC) displays. It represents the first step in our effort to reexamine the color vision standards for air traffic controllers. The current job-related color vision tests us...

  20. Polyvalent Display of Biomolecules on Live Cells.

    PubMed

    Shi, Peng; Zhao, Nan; Lai, Jinping; Coyne, James; Gaddes, Erin R; Wang, Yong

    2018-06-04

    Surface display of biomolecules on live cells offers new opportunities to treat human diseases and perform basic studies. Existing methods are primarily focused on monovalent functionalization, that is, the display of single biomolecules across the cell surface. Here we show that the surface of live cells can be functionalized to display polyvalent biomolecular structures through two-step reactions under physiological conditions. This polyvalent functionalization enables the cell surface to recognize the microenvironment one order of magnitude more effectively than with monovalent functionalization. Thus, polyvalent display of biomolecules on live cells holds great potential for various biological and biomedical applications. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Data Display Markup Language (DDML) Handbook

    DTIC Science & Technology

    2017-01-31

    Moreover, the tendency of T&E is towards a plug-and-play-like data acquisition system that requires standard languages and modules for data displays...Telemetry Group DOCUMENT 127-17 DATA DISPLAY MARKUP LANGUAGE (DDML) HANDBOOK DISTRIBUTION A: APPROVED FOR...DOCUMENT 127-17 DATA DISPLAY MARKUP LANGUAGE (DDML) HANDBOOK January 2017 Prepared by Telemetry Group

  2. The effect of electromagnetic interference from mobile communication on the performance of intensive care ventilators.

    PubMed

    Jones, R P; Conway, D H

    2005-08-01

    Electromagnetic interference produced by wireless communication can affect medical devices and hospital policies exist to address this risk. During the transfer of ventilated patients, these policies may be compromised by essential communication between base and receiving hospitals. Local wireless networks (e.g. Bluetooth) may reduce the 'spaghetti syndrome' of wires and cables seen on intensive care units, but also generate electromagnetic interference. The aim of this study was to investigate these effects on displayed and actual ventilator performance. Five ventilators were tested: Drager Oxylog 2000, BREAS LTV-1000, Respironics BiPAP VISION, Puritan Bennett 7200 and 840. Electromagnetic interference was generated by three devices: Simoco 8020 radio handset, Nokia 7210 and Nokia 6230 mobile phone, Nokia 6230 communicating via Bluetooth with a Palm Tungsten T Personal Digital Assistant. We followed the American National Standard Recommended Practice for On-Site, Ad Hoc Testing (ANSI C63) for electromagnetic interference. We used a ventilator tester, to simulate healthy adult lungs and measure ventilator performance. The communication device under test was moved in towards each ventilator from a distance of 1 m in six axes. Alarms or error codes on the ventilator were recorded, as was ventilator performance. All ventilators tested, except for the Respironics VISION, showed a display error when subjected to electromagnetic interference from the Nokia phones and Simoco radio. Ventilator performance was only affected by the radio which caused the Puritan Bennett 840 to stop functioning completely. The transfer ventilators' performance were not affected by radio or mobile phone, although the mobile phone did trigger a low-power alarm. Effects on intensive care ventilators included display reset, with the ventilator restoring normal display function within 2 s, and low-power/low-pressure alarms. Bluetooth transmission had no effect on the function of all the ventilators tested. In a clinical setting, high-power-output devices such as a two-way radio may cause significant interference in ventilator function. Medium-power-output devices such as mobile phones may cause minor alarm triggers. Low-power-output devices such as Bluetooth appear to cause no interference with ventilator function.

  3. Draft standard for color AMLCDs in U.S. military aircraft

    NASA Astrophysics Data System (ADS)

    Hopper, Darrel G.; Dolezal, William K.; Schur, Keith; Liccione, John W.

    1994-06-01

    Flight instruments have begun to use color active liquid crystal displays (AMLCDs), signaling the beginning of a significant transition from electromechanical and cathode ray tube display designs to AMLCD designs. We have the opportunity with this new technology to establish common products capable of meeting user requirements for sunlight-readable, color and gray scale-capable, high-pixel-count, flat-panel displays for weapon systems. The Wright Laboratory is leading the development of standard and specification documentation for this new generation of display modules based on requirements for U.S. military aircraft. These requirements are similar in many ways to those of both the civil aviation and automotive industries. Accordingly, commonality with these applications is incorporated, where possible, along with the requirements for all military combat applications. Industry and government organizations are involved in this process through workshops and draft review processes. Military procurement specifications for combat system applications may use this information as a source of recommended best practice for this new generation of digital flat panel displays. The draft standard will be revised based upon continuing feedback by early 1995.

  4. Mothers' depressive symptoms in infancy and children's adjustment in grade school: The role of children's sustained attention and executive function.

    PubMed

    Wang, Yiji; Dix, Theodore

    2017-09-01

    On the basis of longitudinal data across 9 years, this study examined the contribution of sustained attention and executive function to the poor cognitive and socioemotional adjustment of school-age children whose mothers had depressive symptoms during the child's infancy. Mothers (N = 1,364) reported depressive symptoms across their child's infancy and early childhood. Maternal sensitivity was observed during laboratory interactions at 36 months. At school entry children's sustained attention and executive function were measured with computer-generated tasks. In third grade, cognitive and socioemotional adjustment was assessed with standardized tests and the reports of fathers and teachers. Using structural equation modeling, findings showed that (a) exposure to mothers' depressive symptoms during the child's infancy, independent of later exposure, uniquely predicted children's poor sustained attention and executive function at school entry; (b) deficits in children's sustained attention and executive function occurred because of depressed mothers' tendencies to display insensitive parenting behavior; and (c) these deficits explained in part relations between exposure to mothers' depressive symptoms in infancy and children's poor cognitive and socioemotional adjustment in third grade. Findings highlight the potential importance of children's exposure to mothers' depressive symptoms specifically during the child's infancy for disrupting the development of fundamental cognitive processes that may underlie the adjustment problems children of depressed mothers display in middle childhood. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  5. Biocompatible and Biomimetic Self-Assembly of Functional Nanostructures

    DTIC Science & Technology

    2017-03-15

    Force Research Laboratory Air Force Materiel Command REPORT DOCUMENTATION PAGE Form ApprovedOMB No. 0704-0188 The public reporting burden for this...failing to comply with a collection of information   if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO...OF: Standard Form 298 (Rev. 8/98) Prescribed by ANSI Std. Z39.18 Page 1 of 2FORM SF 298 3/16/2017https://livelink.ebs.afrl.af.mil/livelink

  6. Assessment of display performance for medical imaging systems: Executive summary of AAPM TG18 report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Samei, Ehsan; Badano, Aldo; Chakraborty, Dev

    Digital imaging provides an effective means to electronically acquire, archive, distribute, and view medical images. Medical imaging display stations are an integral part of these operations. Therefore, it is vitally important to assure that electronic display devices do not compromise image quality and ultimately patient care. The AAPM Task Group 18 (TG18) recently published guidelines and acceptance criteria for acceptance testing and quality control of medical display devices. This paper is an executive summary of the TG18 report. TG18 guidelines include visual, quantitative, and advanced testing methodologies for primary and secondary class display devices. The characteristics, tested in conjunction withmore » specially designed test patterns (i.e., TG18 patterns), include reflection, geometric distortion, luminance, the spatial and angular dependencies of luminance, resolution, noise, glare, chromaticity, and display artifacts. Geometric distortions are evaluated by linear measurements of the TG18-QC test pattern, which should render distortion coefficients less than 2%/5% for primary/secondary displays, respectively. Reflection measurements include specular and diffuse reflection coefficients from which the maximum allowable ambient lighting is determined such that contrast degradation due to display reflection remains below a 20% limit and the level of ambient luminance (L{sub amb}) does not unduly compromise luminance ratio (LR) and contrast at low luminance levels. Luminance evaluation relies on visual assessment of low contrast features in the TG18-CT and TG18-MP test patterns, or quantitative measurements at 18 distinct luminance levels of the TG18-LN test patterns. The major acceptable criteria for primary/secondary displays are maximum luminance of greater than 170/100 cd/m{sup 2}, LR of greater than 250/100, and contrast conformance to that of the grayscale standard display function (GSDF) of better than 10%/20%, respectively. The angular response is tested to ascertain the viewing cone within which contrast conformance to the GSDF is better than 30%/60% and LR is greater than 175/70 for primary/secondary displays, or alternatively, within which the on-axis contrast thresholds of the TG18-CT test pattern remain discernible. The evaluation of luminance spatial uniformity at two distinct luminance levels across the display faceplate using TG18-UNL test patterns should yield nonuniformity coefficients smaller than 30%. The resolution evaluation includes the visual scoring of the CX test target in the TG18-QC or TG18-CX test patterns, which should yield scores greater than 4/6 for primary/secondary displays. Noise evaluation includes visual evaluation of the contrast threshold in the TG18-AFC test pattern, which should yield a minimum of 3/2 targets visible for primary/secondary displays. The guidelines also include methodologies for more quantitative resolution and noise measurements based on MTF and NPS analyses. The display glare test, based on the visibility of the low-contrast targets of the TG18-GV test pattern or the measurement of the glare ratio (GR), is expected to yield scores greater than 3/1 and GRs greater than 400/150 for primary/secondary displays. Chromaticity, measured across a display faceplate or between two display devices, is expected to render a u{sup '},v{sup '} color separation of less than 0.01 for primary displays. The report offers further descriptions of prior standardization efforts, current display technologies, testing prerequisites, streamlined procedures and timelines, and TG18 test patterns.« less

  7. Accessibility Attributes of Blood Glucose Meter and Home Blood Pressure Monitor Displays for Visually Impaired Persons

    PubMed Central

    Blubaugh, Morgan V.; Uslan, Mark M.

    2012-01-01

    The vast majority of diabetes-related self-management technology utilizes small visual displays (SVDs) that often produce a low level of contrast and suffer from high levels of reflection (glare). This is a major accessibility issue for the 3.5 million Americans with diabetes who have reduced vision. The purpose of this article is to gather comparative data on the key display attributes of the SVDs used in blood glucose meters (BGMs) and home blood pressure monitors (HBPMs) on the market today and determine which displays offer the best prospect for being accessible to people with reduced vision. Nine BGMs and eight HBPMs were identified for this study on the basis of amount of devices sold, full-functionality speech output, and advanced display technologies. An optical instrumentation system obtained contrast, reflection (glare), and font height measurements for all 17 displays. The contrast, reflection, and font-height values for the BGMs and HBPMs varied greatly between models. The Michelson contrast values for the BGMs ranged from 11% to 98% and font heights ranged 0.39–1.00 in. for the measurement results. The HBPMs had Michelson contrast values ranging 55–96% and font height ranging 0.28–0.94 in. for the measurement results. Due largely to the lack of display design standards for the technical requirements of SVDs, there is tremendous variability in the quality and readability of BGM and HBPM displays. There were two BGMs and one HBPM that exhibited high-contrast values and large font heights, but most of the devices exhibited either poor contrast or exceptionally high reflection. PMID:22538132

  8. WE-D-204-03: A Six-Year Longitudinal Evaluation of the DICOM GSDF Conformance Stability of LCD Monitors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McKenney, S; Bevins, N; Flynn, M

    2015-06-15

    Purpose: The calibration of monitors in radiology is critical to ensure a standardized reading environment. If left unchecked, monitors initially calibrated to follow the DICOM Grayscale Standard Display Function (GSDF) can fall out of calibration. This work presents a quantitative evaluation of the stability of a cohort of monitors with similar deployment times and clinical utilization. Methods: Fifty-four liquid crystal display (LCD) monitors (NEC L200ME) were deployed for clinical use in 2009. At that time, a subset of eight of these monitors were used to generate a look-up table (LUT) using the open-source software pacsDisplay. The software was used tomore » load the LUT to the graphics card of the computer in order to make the monitors compliant with the GSDF. The luminance response of the monitors was evaluated twice over six years, once in 2011 and again in 2015. Results: As expected, the maximum luminance of the monitors decreased over time, with an average reduction from 2009 of 35% in 2011, and 53% in 2015. The luminance ratio (maximum luminance divided by the minimum) also decreased, with the all of the decrease occurring in the first two years (average 20%). There was an overall increase in relative error compared with the DICOM GSDF from measurement to measurement, indicating that deviation from the GSDF increases with monitor luminance reduction. Along with changes in luminance, several other issues were identified during the testing, including non-uniformities, bad pixels, and missing calibration software. Conclusion: From the initial installation of these monitors, most of the degradation occurred during the first two years, highlighting the importance of routine clinical testing of displays. Following such quality assurance, displays could be either re-calibrated or replaced depending on different thresholds. In addition, other issues not related to luminance could be identified and corrected.« less

  9. Image Format Conversion to DICOM and Lookup Table Conversion to Presentation Value of the Japanese Society of Radiological Technology (JSRT) Standard Digital Image Database.

    PubMed

    Yanagita, Satoshi; Imahana, Masato; Suwa, Kazuaki; Sugimura, Hitomi; Nishiki, Masayuki

    2016-01-01

    Japanese Society of Radiological Technology (JSRT) standard digital image database contains many useful cases of chest X-ray images, and has been used in many state-of-the-art researches. However, the pixel values of all the images are simply digitized as relative density values by utilizing a scanned film digitizer. As a result, the pixel values are completely different from the standardized display system input value of digital imaging and communications in medicine (DICOM), called presentation value (P-value), which can maintain a visual consistency when observing images using different display luminance. Therefore, we converted all the images from JSRT standard digital image database to DICOM format followed by the conversion of the pixel values to P-value using an original program developed by ourselves. Consequently, JSRT standard digital image database has been modified so that the visual consistency of images is maintained among different luminance displays.

  10. Imaging acquisition display performance: an evaluation and discussion of performance metrics and procedures.

    PubMed

    Silosky, Michael S; Marsh, Rebecca M; Scherzinger, Ann L

    2016-07-08

    When The Joint Commission updated its Requirements for Diagnostic Imaging Services for hospitals and ambulatory care facilities on July 1, 2015, among the new requirements was an annual performance evaluation for acquisition workstation displays. The purpose of this work was to evaluate a large cohort of acquisition displays used in a clinical environment and compare the results with existing performance standards provided by the American College of Radiology (ACR) and the American Association of Physicists in Medicine (AAPM). Measurements of the minimum luminance, maximum luminance, and luminance uniformity, were performed on 42 acquisition displays across multiple imaging modalities. The mean values, standard deviations, and ranges were calculated for these metrics. Additionally, visual evaluations of contrast, spatial resolution, and distortion were performed using either the Society of Motion Pictures and Television Engineers test pattern or the TG-18-QC test pattern. Finally, an evaluation of local nonuniformities was performed using either a uniform white display or the TG-18-UN80 test pattern. Displays tested were flat panel, liquid crystal displays that ranged from less than 1 to up to 10 years of use and had been built by a wide variety of manufacturers. The mean values for Lmin and Lmax for the displays tested were 0.28 ± 0.13 cd/m2 and 135.07 ± 33.35 cd/m2, respectively. The mean maximum luminance deviation for both ultrasound and non-ultrasound displays was 12.61% ± 4.85% and 14.47% ± 5.36%, respectively. Visual evaluation of display performance varied depending on several factors including brightness and contrast settings and the test pattern used for image quality assessment. This work provides a snapshot of the performance of 42 acquisition displays across several imaging modalities in clinical use at a large medical center. Comparison with existing performance standards reveals that changes in display technology and the move from cathode ray tube displays to flat panel displays may have rendered some of the tests inappropriate for modern use. © 2016 The Authors.

  11. A problem-solving task specialized for functional neuroimaging: validation of the Scarborough adaptation of the Tower of London (S-TOL) using near-infrared spectroscopy

    PubMed Central

    Ruocco, Anthony C.; Rodrigo, Achala H.; Lam, Jaeger; Di Domenico, Stefano I.; Graves, Bryanna; Ayaz, Hasan

    2014-01-01

    Problem-solving is an executive function subserved by a network of neural structures of which the dorsolateral prefrontal cortex (DLPFC) is central. Whereas several studies have evaluated the role of the DLPFC in problem-solving, few standardized tasks have been developed specifically for use with functional neuroimaging. The current study adapted a measure with established validity for the assessment of problem-solving abilities to design a test more suitable for functional neuroimaging protocols. The Scarborough adaptation of the Tower of London (S-TOL) was administered to 38 healthy adults while hemodynamic oxygenation of the PFC was measured using 16-channel continuous-wave functional near-infrared spectroscopy (fNIRS). Compared to a baseline condition, problems that required two or three steps to achieve a goal configuration were associated with higher activation in the left DLPFC and deactivation in the medial PFC. Individuals scoring higher in trait deliberation showed consistently higher activation in the left DLPFC regardless of task difficulty, whereas individuals lower in this trait displayed less activation when solving simple problems. Based on these results, the S-TOL may serve as a standardized task to evaluate problem-solving abilities in functional neuroimaging studies. PMID:24734017

  12. A transversal approach to predict gene product networks from ontology-based similarity

    PubMed Central

    Chabalier, Julie; Mosser, Jean; Burgun, Anita

    2007-01-01

    Background Interpretation of transcriptomic data is usually made through a "standard" approach which consists in clustering the genes according to their expression patterns and exploiting Gene Ontology (GO) annotations within each expression cluster. This approach makes it difficult to underline functional relationships between gene products that belong to different expression clusters. To address this issue, we propose a transversal analysis that aims to predict functional networks based on a combination of GO processes and data expression. Results The transversal approach presented in this paper consists in computing the semantic similarity between gene products in a Vector Space Model. Through a weighting scheme over the annotations, we take into account the representativity of the terms that annotate a gene product. Comparing annotation vectors results in a matrix of gene product similarities. Combined with expression data, the matrix is displayed as a set of functional gene networks. The transversal approach was applied to 186 genes related to the enterocyte differentiation stages. This approach resulted in 18 functional networks proved to be biologically relevant. These results were compared with those obtained through a standard approach and with an approach based on information content similarity. Conclusion Complementary to the standard approach, the transversal approach offers new insight into the cellular mechanisms and reveals new research hypotheses by combining gene product networks based on semantic similarity, and data expression. PMID:17605807

  13. Prototype of Partial Cutting Tool of Geological Map Images Distributed by Geological Web Map Service

    NASA Astrophysics Data System (ADS)

    Nonogaki, S.; Nemoto, T.

    2014-12-01

    Geological maps and topographical maps play an important role in disaster assessment, resource management, and environmental preservation. These map information have been distributed in accordance with Web services standards such as Web Map Service (WMS) and Web Map Tile Service (WMTS) recently. In this study, a partial cutting tool of geological map images distributed by geological WMTS was implemented with Free and Open Source Software. The tool mainly consists of two functions: display function and cutting function. The former function was implemented using OpenLayers. The latter function was implemented using Geospatial Data Abstraction Library (GDAL). All other small functions were implemented by PHP and Python. As a result, this tool allows not only displaying WMTS layer on web browser but also generating a geological map image of intended area and zoom level. At this moment, available WTMS layers are limited to the ones distributed by WMTS for the Seamless Digital Geological Map of Japan. The geological map image can be saved as GeoTIFF format and WebGL format. GeoTIFF is one of the georeferenced raster formats that is available in many kinds of Geographical Information System. WebGL is useful for confirming a relationship between geology and geography in 3D. In conclusion, the partial cutting tool developed in this study would contribute to create better conditions for promoting utilization of geological information. Future work is to increase the number of available WMTS layers and the types of output file format.

  14. Effect of Display Color on Pilot Performance and Describing Functions

    NASA Technical Reports Server (NTRS)

    Chase, Wendell D.

    1997-01-01

    A study has been conducted with the full-spectrum, calligraphic, computer-generated display system to determine the effect of chromatic content of the visual display upon pilot performance during the landing approach maneuver. This study utilizes a new digital chromatic display system, which has previously been shown to improve the perceived fidelity of out-the-window display scenes, and presents the results of an experiment designed to determine the effects of display color content by the measurement of both vertical approach performance and pilot-describing functions. This method was selected to more fully explore the effects of visual color cues used by the pilot. Two types of landing approaches were made: dynamic and frozen range, with either a landing approach scene or a perspective array display. The landing approach scene was presented with either red runway lights and blue taxiway lights or with the colors reversed, and the perspective array with red lights, blue lights, or red and blue lights combined. The vertical performance measures obtained in this experiment indicated that the pilots performed best with the blue and red/blue displays. and worst with the red displays. The describing-function system analysis showed more variation with the red displays. The crossover frequencies were lowest with the red displays and highest with the combined red/blue displays, which provided the best overall tracking, performance. Describing-function performance measures, vertical performance measures, and pilot opinion support the hypothesis that specific colors in displays can influence the pilots' control characteristics during the final approach.

  15. Status signals: adaptive benefits of displaying and observing the nonverbal expressions of pride and shame.

    PubMed

    Martens, Jason P; Tracy, Jessica L; Shariff, Azim F

    2012-01-01

    A growing body of research suggests that pride and shame are associated with distinct, cross-culturally recognised nonverbal expressions, which are spontaneously displayed in situations of success and failure, respectively. Here, we review these findings, then offer a theoretical account of the adaptive benefits of these displays. We argue that both pride and shame expressions function as social signals that benefit both observers and expressers. Specifically, pride displays function to signal high status, which benefits displayers by according them deference from others, and benefits observers by affording them valuable information about social-learning opportunities. Shame displays function to appease others after a social transgression, which benefits displayers by allowing them to avoid punishment and negative appraisals, and observers by easing their identification of committed group members and followers.

  16. Evolution of the pygmy dipole resonance in Sn isotopes

    NASA Astrophysics Data System (ADS)

    Toft, H. K.; Larsen, A. C.; Bürger, A.; Guttormsen, M.; Görgen, A.; Nyhus, H. T.; Renstrøm, T.; Siem, S.; Tveten, G. M.; Voinov, A.

    2011-04-01

    Nuclear level density and γ-ray strength functions of Sn121,122 below the neutron separation energy are extracted with the Oslo method using the (He3,He3'γ) and (He3,αγ) reactions. The level densities of Sn121,122 display steplike structures, interpreted as signatures of neutron pair breaking. An enhancement in both strength functions, compared to standard models for radiative strength, is observed in our measurements for Eγ≳5.2 MeV. This enhancement is compatible with pygmy resonances centered at ≈8.4(1) and ≈8.6(2) MeV, respectively, and with integrated strengths corresponding to ≈1.8-5+1% of the classical Thomas-Reiche-Kuhn sum rule. Similar resonances were also seen in Sn116-119. Experimental neutron-capture cross reactions are well reproduced by our pygmy resonance predictions, while standard strength models are less successful. The evolution as a function of neutron number of the pygmy resonance in Sn116-122 is described as a clear increase of centroid energy from 8.0(1) to 8.6(2) MeV, but with no observable difference in integrated strengths.

  17. Presentation of Information on Visual Displays.

    ERIC Educational Resources Information Center

    Pettersson, Rune

    This discussion of factors involved in the presentation of text, numeric data, and/or visuals using video display devices describes in some detail the following types of presentation: (1) visual displays, with attention to additive color combination; measurements, including luminance, radiance, brightness, and lightness; and standards, with…

  18. An evaluation of the ELT-8 hematology analyzer.

    PubMed

    Raik, E; McPherson, J; Barton, L; Hewitt, B S; Powell, E G; Gordon, S

    1982-04-01

    The TMELT-8 Hematology Analyzer is a fully automated cell counter which utilizes laser light scattering and hydrodynamic focusing to provide an 8 parameter whole blood count. The instrument consists of a sample handler with ticket printer, and a data handler with visual display unit, It accepts 100 microliter samples of venous or capillary blood and prints the values for WCC, RCC, Hb, Hct, MCV, MCH, MCHC and platelet count on to a standard result card. All operational and quality control functions, including graphic display of relative cell size distribution, can be obtained from the visual display unit and can also be printed as a permanent record if required. In a limited evaluation of the ELT-8, precision, linearity, accuracy, lack of sample carry-over and user acceptance were excellent. Reproducible values were obtained for all parameters after overnight storage of samples. Reagent usage and running costs were lower than for the Coulter S and the Coulter S Plus. The ease of processing capillary samples was considered to be a major advantage. The histograms served to alert the operator to a number of abnormalities, some of which were clinically significant.

  19. X-window-based 2K display workstation

    NASA Astrophysics Data System (ADS)

    Weinberg, Wolfram S.; Hayrapetian, Alek S.; Cho, Paul S.; Valentino, Daniel J.; Taira, Ricky K.; Huang, H. K.

    1991-07-01

    A high-definition, high-performance display station for reading and review of digital radiological images is introduced. The station is based on a Sun SPARC Station 4 and employs X window system for display and manipulation of images. A mouse-operated graphic user interface is implemented utilizing Motif-style tools. The system supports up to four MegaScan gray-scale 2560 X 2048 monitors. A special configuration of frame and video buffer yields a data transfer of 50 M pixels/s. A magnetic disk array supplies a storage capacity of 2 GB with a data transfer rate of 4-6 MB/s. The system has access to the central archive through an ultrahigh-speed fiber-optic network and patient studies are automatically transferred to the local disk. The available image processing functions include change of lookup table, zoom and pan, and cine. Future enhancements will provide for manual contour tracing, length, area, and density measurements, text and graphic overlay, as well as composition of selected images. Additional preprocessing procedures under development will optimize the initial lookup table and adjust the images to a standard orientation.

  20. Java Architecture for Detect and Avoid Extensibility and Modeling

    NASA Technical Reports Server (NTRS)

    Santiago, Confesor; Mueller, Eric Richard; Johnson, Marcus A.; Abramson, Michael; Snow, James William

    2015-01-01

    Unmanned aircraft will equip with a detect-and-avoid (DAA) system that enables them to comply with the requirement to "see and avoid" other aircraft, an important layer in the overall set of procedural, strategic and tactical separation methods designed to prevent mid-air collisions. This paper describes a capability called Java Architecture for Detect and Avoid Extensibility and Modeling (JADEM), developed to prototype and help evaluate various DAA technological requirements by providing a flexible and extensible software platform that models all major detect-and-avoid functions. Figure 1 illustrates JADEM's architecture. The surveillance module can be actual equipment on the unmanned aircraft or simulators that model the process by which sensors on-board detect other aircraft and provide track data to the traffic display. The track evaluation function evaluates each detected aircraft and decides whether to provide an alert to the pilot and its severity. Guidance is a combination of intruder track information, alerting, and avoidance/advisory algorithms behind the tools shown on the traffic display to aid the pilot in determining a maneuver to avoid a loss of well clear. All these functions are designed with a common interface and configurable implementation, which is critical in exploring DAA requirements. To date, JADEM has been utilized in three computer simulations of the National Airspace System, three pilot-in-the-loop experiments using a total of 37 professional UAS pilots, and two flight tests using NASA's Predator-B unmanned aircraft, named Ikhana. The data collected has directly informed the quantitative separation standard for "well clear", safety case, requirements development, and the operational environment for the DAA minimum operational performance standards. This work was performed by the Separation Assurance/Sense and Avoid Interoperability team under NASA's UAS Integration in the NAS project.

  1. Using ARINC 818 Avionics Digital Video Bus (ADVB) for military displays

    NASA Astrophysics Data System (ADS)

    Alexander, Jon; Keller, Tim

    2007-04-01

    ARINC 818 Avionics Digital Video Bus (ADVB) is a new digital video interface and protocol standard developed especially for high bandwidth uncompressed digital video. The first draft of this standard, released in January of 2007, has been advanced by ARINC and the aerospace community to meet the acute needs of commercial aviation for higher performance digital video. This paper analyzes ARINC 818 for use in military display systems found in avionics, helicopters, and ground vehicles. The flexibility of ARINC 818 for the diverse resolutions, grayscales, pixel formats, and frame rates of military displays is analyzed as well as the suitability of ARINC 818 to support requirements for military video systems including bandwidth, latency, and reliability. Implementation issues relevant to military displays are presented.

  2. 25 CFR 547.8 - What are the minimum technical software standards applicable to Class II gaming systems?

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... OF CLASS II GAMES § 547.8 What are the minimum technical software standards applicable to Class II... of Class II games. (a) Player interface displays. (1) If not otherwise provided to the player, the player interface shall display the following: (i) The purchase or wager amount; (ii) Game results; and...

  3. 25 CFR 547.8 - What are the minimum technical software standards applicable to Class II gaming systems?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... OF CLASS II GAMES § 547.8 What are the minimum technical software standards applicable to Class II... of Class II games. (a) Player interface displays. (1) If not otherwise provided to the player, the player interface shall display the following: (i) The purchase or wager amount; (ii) Game results; and...

  4. 25 CFR 547.8 - What are the minimum technical software standards applicable to Class II gaming systems?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... OF CLASS II GAMES § 547.8 What are the minimum technical software standards applicable to Class II... of Class II games. (a) Player interface displays. (1) If not otherwise provided to the player, the player interface shall display the following: (i) The purchase or wager amount; (ii) Game results; and...

  5. Graphical display of histopathology data from toxicology studies for drug discovery and development: An industry perspective.

    PubMed

    Brown, Alan P; Drew, Philip; Knight, Brian; Marc, Philippe; Troth, Sean; Wuersch, Kuno; Zandee, Joyce

    2016-12-01

    Histopathology data comprise a critical component of pharmaceutical toxicology studies and are typically presented as finding incidence counts and severity scores per organ, and tabulated on multiple pages which can be challenging for review and aggregation of results. However, the SEND (Standard for Exchange of Nonclinical Data) standard provides a means for collecting and managing histopathology data in a uniform fashion which can allow informatics systems to archive, display and analyze data in novel ways. Various software applications have become available to convert histopathology data into graphical displays for analyses. A subgroup of the FDA-PhUSE Nonclinical Working Group conducted intra-industry surveys regarding the use of graphical displays of histopathology data. Visual cues, use-cases, the value of cross-domain and cross-study visualizations, and limitations were topics for discussion in the context of the surveys. The subgroup came to the following conclusions. Graphical displays appear advantageous as a communication tool to both pathologists and non-pathologists, and provide an efficient means for communicating pathology findings to project teams. Graphics can support hypothesis-generation which could include cross-domain interactive visualizations and/-or aggregating large datasets from multiple studies to observe and/or display patterns and trends. Incorporation of the SEND standard will provide a platform by which visualization tools will be able to aggregate, select and display information from complex and disparate datasets. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Interpretation of the rainbow color scale for quantitative medical imaging: perceptually linear color calibration (CSDF) versus DICOM GSDF

    NASA Astrophysics Data System (ADS)

    Chesterman, Frédérique; Manssens, Hannah; Morel, Céline; Serrell, Guillaume; Piepers, Bastian; Kimpe, Tom

    2017-03-01

    Medical displays for primary diagnosis are calibrated to the DICOM GSDF1 but there is no accepted standard today that describes how display systems for medical modalities involving color should be calibrated. Recently the Color Standard Display Function3,4 (CSDF), a calibration using the CIEDE2000 color difference metric to make a display as perceptually linear as possible has been proposed. In this work we present the results of a first observer study set up to investigate the interpretation accuracy of a rainbow color scale when a medical display is calibrated to CSDF versus DICOM GSDF and a second observer study set up to investigate the detectability of color differences when a medical display is calibrated to CSDF, DICOM GSDF and sRGB. The results of the first study indicate that the error when interpreting a rainbow color scale is lower for CSDF than for DICOM GSDF with statistically significant difference (Mann-Whitney U test) for eight out of twelve observers. The results correspond to what is expected based on CIEDE2000 color differences between consecutive colors along the rainbow color scale for both calibrations. The results of the second study indicate a statistical significant improvement in detecting color differences when a display is calibrated to CSDF compared to DICOM GSDF and a (non-significant) trend indicating improved detection for CSDF compared to sRGB. To our knowledge this is the first work that shows the added value of a perceptual color calibration method (CSDF) in interpreting medical color images using the rainbow color scale. Improved interpretation of the rainbow color scale may be beneficial in the area of quantitative medical imaging (e.g. PET SUV, quantitative MRI and CT and doppler US), where a medical specialist needs to interpret quantitative medical data based on a color scale and/or detect subtle color differences and where improved interpretation accuracy and improved detection of color differences may contribute to a better diagnosis. Our results indicate that for diagnostic applications involving both grayscale and color images, CSDF should be chosen over DICOM GSDF and sRGB as it assures excellent detection for color images and at the same time maintains DICOM GSDF for grayscale images.

  7. Does contextual cuing guide the deployment of attention?

    PubMed

    Kunar, Melina A; Flusberg, Stephen; Horowitz, Todd S; Wolfe, Jeremy M

    2007-08-01

    Contextual cuing experiments show that when displays are repeated, reaction times to find a target decrease over time even when observers are not aware of the repetition. It has been thought that the context of the display guides attention to the target. The authors tested this hypothesis by comparing the effects of guidance in a standard search task with the effects of contextual cuing. First, in standard search, an improvement in guidance causes search slopes (derived from Reaction Time x Set Size functions) to decrease. In contrast, the authors found that search slopes in contextual cuing did not become more efficient over time (Experiment 1). Second, when guidance was optimal (e.g., in easy feature search), they still found a small but reliable contextual cuing effect (Experiments 2a and 2b), suggesting that other factors, such as response selection, contribute to the effect. Experiment 3 supported this hypothesis by showing that the contextual cuing effect disappeared when the authors added interference to the response selection process. Overall, the data suggest that the relationship between guidance and contextual cuing is weak and that response selection can account for part of the effect. (c) 2007 APA, all rights reserved

  8. Handheld hyperspectral imager system for chemical/biological and environmental applications

    NASA Astrophysics Data System (ADS)

    Hinnrichs, Michele; Piatek, Bob

    2004-08-01

    A small, hand held, battery operated imaging infrared spectrometer, Sherlock, has been developed by Pacific Advanced Technology and was field tested in early 2003. The Sherlock spectral imaging camera has been designed for remote gas leak detection, however, the architecture of the camera is versatile enough that it can be applied to numerous other applications such as homeland security, chemical/biological agent detection, medical and pharmaceutical applications as well as standard research and development. This paper describes the Sherlock camera, theory of operations, shows current applications and touches on potential future applications for the camera. The Sherlock has an embedded Power PC and performs real-time-image processing function in an embedded FPGA. The camera has a built in LCD display as well as output to a standard monitor, or NTSC display. It has several I/O ports, ethernet, firewire, RS232 and thus can be easily controlled from a remote location. In addition, software upgrades can be performed over the ethernet eliminating the need to send the camera back to the factory for a retrofit. Using the USB port a mouse and key board can be connected and the camera can be used in a laboratory environment as a stand alone imaging spectrometer.

  9. Hand-held hyperspectral imager for chemical/biological and environmental applications

    NASA Astrophysics Data System (ADS)

    Hinnrichs, Michele; Piatek, Bob

    2004-03-01

    A small, hand held, battery operated imaging infrared spectrometer, Sherlock, has been developed by Pacific Advanced Technology and was field tested in early 2003. The Sherlock spectral imaging camera has been designed for remote gas leak detection, however, the architecture of the camera is versatile enough that it can be applied to numerous other applications such as homeland security, chemical/biological agent detection, medical and pharmaceutical applications as well as standard research and development. This paper describes the Sherlock camera, theory of operations, shows current applications and touches on potential future applications for the camera. The Sherlock has an embedded Power PC and performs real-time-image processing function in an embedded FPGA. The camera has a built in LCD display as well as output to a standard monitor, or NTSC display. It has several I/O ports, ethernet, firewire, RS232 and thus can be easily controlled from a remote location. In addition, software upgrades can be performed over the ethernet eliminating the need to send the camera back to the factory for a retrofit. Using the USB port a mouse and key board can be connected and the camera can be used in a laboratory environment as a stand alone imaging spectrometer.

  10. Expanding the versatility of phage display I: efficient display of peptide-tags on protein VII of the filamentous phage.

    PubMed

    Løset, Geir Åge; Bogen, Bjarne; Sandlie, Inger

    2011-02-24

    Phage display is a platform for selection of specific binding molecules and this is a clear-cut motivation for increasing its performance. Polypeptides are normally displayed as fusions to the major coat protein VIII (pVIII), or the minor coat protein III (pIII). Display on other coat proteins such as pVII allows for display of heterologous peptide sequences on the virions in addition to those displayed on pIII and pVIII. In addition, pVII display is an alternative to pIII or pVIII display. Here we demonstrate how standard pIII or pVIII display phagemids are complemented with a helper phage which supports production of virions that are tagged with octa FLAG, HIS(6) or AviTag on pVII. The periplasmic signal sequence required for pIII and pVIII display, and which has been added to pVII in earlier studies, is omitted altogether. Tagging on pVII is an important and very useful add-on feature to standard pIII and pVII display. Any phagemid bearing a protein of interest on either pIII or pVIII can be tagged with any of the tags depending simply on choice of helper phage. We show in this paper how such tags may be utilized for immobilization and separation as well as purification and detection of monoclonal and polyclonal phage populations.

  11. Master Console, SMC

    NASA Technical Reports Server (NTRS)

    Paga Marrero, Hector Jose

    2013-01-01

    The Master Console oversees the function of Computer Systems in Firing room 1 (FR1). Master Console Operators, MCOs' for short, are our customer. I was integrated into the System Monitoring and Control (SMC) software team that is under the guidance of David Slaiman, who is the product group lead. I have been brought up to speed with System Monitoring and Control. The initial time spent reading SMC software design description and understanding how it works. The current Firing Room 1 Console Display is a floor layout giving the MCO two essential pieces of information which are Health and Status. When an issue arises, the MCO has to look on the display to find which console is affected and then the MCO must use the Reference designator from the display to manually search for the Portal Workstation (PWS) installed in the console using the hardware map; which is a long process to lookup a PWS if an issue is present. My project is to make the FR1 Console Display easier for the MCO's to pinpoint PWS's without having to lookup additional resources in the process. My project also includes updating Firing Room 1 Console Display to include the F1R Non-Redundant Set. The display does not have good use of space and functionality. PWS numbers were not present in the previous design and are the critical component in efficient understanding and administration of the consoles. Part of the process includes getting feedback from the customer, instead of just emailing them with a question, we made a proposal with changes so they could respond and give us their input; which proved to be an effective method for engaging them. In order to do this I had to use the Display Editor (DE) tool developed by NASA, Paint.Net and Visio. The process I have been using has been Visio to alter the floor layout of Firing Room and take advantage of the white areas, and then I take the altered floor plan into Paint.Net. Once in Paint.Net I put the new floor plan as a background to the standard console display. Paint.Net also serves as a tool to create the new service state bars for the new background; finally I used the DE to assemble everything and setup the right CUI's for each PWS.

  12. Recommendations for standards in transthoracic two-dimensional echocardiography in the dog and cat. Echocardiography Committee of the Specialty of Cardiology, American College of Veterinary Internal Medicine.

    PubMed

    Thomas, W P; Gaber, C E; Jacobs, G J; Kaplan, P M; Lombard, C W; Moise, N S; Moses, B L

    1993-01-01

    Recommendations are presented for standardized imaging planes and display conventions for two-dimensional echocardiography in the dog and cat. Three transducer locations ("windows") provide access to consistent imaging planes: the right parasternal location, the left caudal (apical) parasternal location, and the left cranial parasternal location. Recommendations for image display orientations are very similar to those for comparable human cardiac images, with the heart base or cranial aspect of the heart displayed to the examiner's right on the video display. From the right parasternal location, standard views include a long-axis four-chamber view and a long-axis left ventricular outflow view, and short-axis views at the levels of the left ventricular apex, papillary muscles, chordae tendineae, mitral valve, aortic valve, and pulmonary arteries. From the left caudal (apical) location, standard views include long-axis two-chamber and four-chamber views. From the left cranial parasternal location, standard views include a long-axis view of the left ventricular outflow tract and ascending aorta (with variations to image the right atrium and tricuspid valve, and the pulmonary valve and pulmonary artery), and a short-axis view of the aortic root encircled by the right heart. These images are presented by means of idealized line drawings. Adoption of these standards should facilitate consistent performance, recording, teaching, and communicating results of studies obtained by two-dimensional echocardiography.

  13. NIST display colorimeter calibration facility

    NASA Astrophysics Data System (ADS)

    Brown, Steven W.; Ohno, Yoshihiro

    2003-07-01

    A facility has been developed at the National Institute of Standards and Technology (NIST) to provide calibration services for color-measuring instruments to address the need for improving and certifying the measurement uncertainties of this type of instrument. While NIST has active programs in photometry, flat panel display metrology, and color and appearance measurements, these are the first services offered by NIST tailored to color-measuring instruments for displays. An overview of the facility, the calibration approach, and associated uncertainties are presented. Details of a new tunable colorimetric source and the development of new transfer standard instruments are discussed.

  14. A simple integrative method for presenting head-contingent motion parallax and disparity cues on intel x86 processor-based machines.

    PubMed

    Szatmary, J; Hadani, I; Julesz, B

    1997-01-01

    Rogers and Graham (1979) developed a system to show that head-movement-contingent motion parallax produces monocular depth perception in random dot patterns. Their display system comprised an oscilloscope driven by function generators or a special graphics board that triggered the X and Y deflection of the raster scan signal. Replication of this system required costly hardware that is no longer on the market. In this paper the Rogers-Graham method is reproduced with an Intel processor based IBM PC compatible machine with no additional hardware cost. An adapted joystick sampled through the standard game-port can serve as a provisional head-movement sensor. Monitor resolution for displaying motion is effectively enhanced 16 times by the use of anti-aliasing, enabling the display of thousands of random dots in real-time with a refresh rate of 60 Hz or above. A color monitor enables the use of the anaglyph method, thus combining stereoscopic and monocular parallax on a single display without the loss of speed. The power of this system is demonstrated by a psychophysical measurement in which subjects nulled head-movement-contingent illusory parallax, evoked by a static stereogram, with real parallax. The amount of real parallax required to null the illusory stereoscopic parallax monotonically increased with disparity.

  15. Effect of color on pilot performance and transfer functions using a full-spectrum, calligraphic, color display system

    NASA Technical Reports Server (NTRS)

    Chase, W. D.

    1976-01-01

    The use of blue and red color in out-of-window cockpit displays, in full-spectrum calligraphic computer-generated display systems, is studied with attention given to pilot stereographic depth perception and response to visual cues. Displays for vertical approach, with dynamic and frozen-range landing approach and perspective arrays, are analyzed. Pilot transfer function and the transfer function associated with the contrasted approach and perspective arrays are discussed. Out-of-window blue lights are perceived by pilots as indicating greater distance depth, red lights as indicating proximity. The computer-generated chromatic display was adapted to flight simulators for the tests.

  16. Context-dependent arm pointing adaptation

    NASA Technical Reports Server (NTRS)

    Seidler, R. D.; Bloomberg, J. J.; Stelmach, G. E.

    2001-01-01

    We sought to determine the effectiveness of head posture as a contextual cue to facilitate adaptive transitions in manual control during visuomotor distortions. Subjects performed arm pointing movements by drawing on a digitizing tablet, with targets and movement trajectories displayed in real time on a computer monitor. Adaptation was induced by presenting the trajectories in an altered gain format on the monitor. The subjects were shown visual displays of their movements that corresponded to either 0.5 or 1.5 scaling of the movements made. Subjects were assigned to three groups: the head orientation group tilted the head towards the right shoulder when drawing under a 0.5 gain of display and towards the left shoulder when drawing under a 1.5 gain of display; the target orientation group had the home and target positions rotated counterclockwise when drawing under the 0.5 gain and clockwise for the 1.5 gain; the arm posture group changed the elbow angle of the arm they were not drawing with from full flexion to full extension with 0.5 and 1.5 gain display changes. To determine if contextual cues were associated with display alternations, the gain changes were returned to the standard (1.0) display. Aftereffects were assessed to determine the efficacy of the head orientation contextual cue compared to the two control cues. The head orientation cue was effectively associated with the multiple gains. The target orientation cue also demonstrated some effectiveness while the arm posture cue did not. The results demonstrate that contextual cues can be used to switch between multiple adaptive states. These data provide support for the idea that static head orientation information is a crucial component to the arm adaptation process. These data further define the functional linkage between head posture and arm pointing movements.

  17. Context-Dependent Arm Pointing Adaptation

    NASA Technical Reports Server (NTRS)

    Seidler, R. D.; Bloomberg, J. J.; Stelmach, G. E.

    2000-01-01

    We sought to determine the effectiveness of head posture as a contextual cue to facilitate adaptive transitions in manual control during visuomotor distortions. Subjects performed arm pointing movements by drawing on a digitizing tablet, with targets and movement trajectories displayed in real time on a computer monitor. Adaptation was induced by presenting the trajectories in an altered gain format on the monitor. The subjects were shown visual displays of their movements that corresponded to either 0.5 or 1.5 scaling of the movements made. Subjects were assigned to three groups: the head orientation group tilted the head towards the right shoulder when drawing under a 0.5 gain of display and towards the left shoulder when drawing under a 1.5 gain of display, the target orientation group had the home & target positions rotated counterclockwise when drawing under the 0.5 gain and clockwise for the 1.5 gain, the arm posture group changed the elbow angle of the arm they were not drawing with from full flexion to full extension with 0.5 and 1.5 gain display changes. To determine if contextual cues were associated with display alternations, the gain changes were returned to the standard (1.0) display. Aftereffects were assessed to determine the efficacy of the head orientation contextual cue. . compared to the two control cues. The head orientation cue was effectively associated with the multiple gains. The target orientation cue also demonstrated some effectiveness while the.arm posture cue did not. The results demonstrate that contextual cues can be used to switch between multiple adaptive states. These data provide support for the idea that static head orientation information is a crucial component to the arm adaptation process. These data further define the functional linkage between head posture and arm pointing movements.

  18. Finding-specific display presets for computed radiography soft-copy reading.

    PubMed

    Andriole, K P; Gould, R G; Webb, W R

    1999-05-01

    Much work has been done to optimize the display of cross-sectional modality imaging examinations for soft-copy reading (i.e., window/level tissue presets, and format presentations such as tile and stack modes, four-on-one, nine-on-one, etc). Less attention has been paid to the display of digital forms of the conventional projection x-ray. The purpose of this study is to assess the utility of providing presets for computed radiography (CR) soft-copy display, based not on the window/level settings, but on processing applied to the image optimized for visualization of specific findings, pathologies, etc (i.e., pneumothorax, tumor, tube location). It is felt that digital display of CR images based on finding-specific processing presets has the potential to: speed reading of digital projection x-ray examinations on soft copy; improve diagnostic efficacy; standardize display across examination type, clinical scenario, important key findings, and significant negatives; facilitate image comparison; and improve confidence in and acceptance of soft-copy reading. Clinical chest images are acquired using an Agfa-Gevaert (Mortsel, Belgium) ADC 70 CR scanner and Fuji (Stamford, CT) 9000 and AC2 CR scanners. Those demonstrating pertinent findings are transferred over the clinical picture archiving and communications system (PACS) network to a research image processing station (Agfa PS5000), where the optimal image-processing settings per finding, pathologic category, etc, are developed in conjunction with a thoracic radiologist, by manipulating the multiscale image contrast amplification (Agfa MUSICA) algorithm parameters. Soft-copy display of images processed with finding-specific settings are compared with the standard default image presentation for 50 cases of each category. Comparison is scored using a 5-point scale with the positive scale denoting the standard presentation is preferred over the finding-specific processing, the negative scale denoting the finding-specific processing is preferred over the standard presentation, and zero denoting no difference. Processing settings have been developed for several findings including pneumothorax and lung nodules, and clinical cases are currently being collected in preparation for formal clinical trials. Preliminary results indicate a preference for the optimized-processing presentation of images over the standard default, particularly by inexperienced radiology residents and referring clinicians.

  19. A virtual image chain for perceived image quality of medical display

    NASA Astrophysics Data System (ADS)

    Marchessoux, Cédric; Jung, Jürgen

    2006-03-01

    This paper describes a virtual image chain for medical display (project VICTOR: granted in the 5th framework program by European commission). The chain starts from raw data of an image digitizer (CR, DR) or synthetic patterns and covers image enhancement (MUSICA by Agfa) and both display possibilities, hardcopy (film on viewing box) and softcopy (monitor). Key feature of the chain is a complete image wise approach. A first prototype is implemented in an object-oriented software platform. The display chain consists of several modules. Raw images are either taken from scanners (CR-DR) or from a pattern generator, in which characteristics of DR- CR systems are introduced by their MTF and their dose-dependent Poisson noise. The image undergoes image enhancement and comes to display. For soft display, color and monochrome monitors are used in the simulation. The image is down-sampled. The non-linear response of a color monitor is taken into account by the GOG or S-curve model, whereas the Standard Gray-Scale-Display-Function (DICOM) is used for monochrome display. The MTF of the monitor is applied on the image in intensity levels. For hardcopy display, the combination of film, printer, lightbox and viewing condition is modeled. The image is up-sampled and the DICOM-GSDF or a Kanamori Look-Up-Table is applied. An anisotropic model for the MTF of the printer is applied on the image in intensity levels. The density-dependent color (XYZ) of the hardcopy film is introduced by Look-Up-tables. Finally a Human Visual System Model is applied to the intensity images (XYZ in terms of cd/m2) in order to eliminate nonvisible differences. Comparison leads to visible differences, which are quantified by higher order image quality metrics. A specific image viewer is used for the visualization of the intensity image and the visual difference maps.

  20. Constancy of built-in luminance meter measurements in diagnostic displays

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Silosky, M., E-mail: michael.silosky@ucdenver.edu; Marsh, R. M.

    2013-12-15

    Purpose: Liquid crystal displays used to interpret medical images are often equipped with built-in luminance meters to evaluate luminance response and Grayscale Standard Display Function conformance. This work evaluates agreement between luminance reported by the built-in meters and external measurements. Methods: The white level luminance was measured using a built-in meter and an external meter for 93 primary review workstations (Models MFGD 3420 and MDCG 3120-CB) with between 117 and 49 336 backlight hours (BLH). Measured luminance values were compared viat-test for displays with less than 25 000 BLH and those with more than 25 000 BLH. Bias between meters was also evaluated.more » Changes in luminance uniformity with increasing backlight hours were explored by determining the maximum luminance deviation (MLD) for subsets of these displays with less than 800 BLH and greater than 35 000 BLH. Results: The mean difference between built-in and external luminance measurements was 5.84% and 38.92% for displays with less than 25 000 and greater than 25 000 BLH, respectively, with a statistically significant difference in the means (p < 0.001). For displays with low BLH, a statistically significant bias was observed (p < 0.001) between built-in and external measurements. A high degree of correlation was observed between measurements made with two separate external meters (r = 0.999). The mean MLD was 9.5% and 11.2% for MDCG 3120-CB displays with less than 800 and greater than 35 000 BLH, respectively. The difference in the mean values was not statistically significant (p < 0.001). Conclusions: Disagreement between the white level luminance measured using the built-in and external meter increased with BLH. Consequently, reliance on values reported by the built-in luminance meter may result in a reduction in image contrast with time. Recommendations have been proposed regarding luminance response testing and corrective action for failing displays.« less

  1. Psychophysical Evaluation of Three-Dimensional Auditory Displays

    NASA Technical Reports Server (NTRS)

    Wightman, Frederic L. (Principal Investigator)

    1995-01-01

    This report describes the process made during the first year of a three-year Cooperative Research Agreement (CRA NCC2-542). The CRA proposed a program of applied of psychophysical research designed to determine the requirements and limitations of three-dimensional (3-D) auditory display systems. These displays present synthesized stimuli to a pilot or virtual workstation operator that evoke auditory images at predetermined positions in space. The images can be either stationary or moving. In previous years. we completed a number of studies that provided data on listeners' abilities to localize stationary sound sources with 3-D displays. The current focus is on the use of 3-D displays in 'natural' listening conditions, which include listeners' head movements, moving sources, multiple sources and 'echoic' sources. The results of our research on two of these topics, the role of head movements and the role of echoes and reflections, were reported in the most recent Semi-Annual Pro-ress Report (Appendix A). In the period since the last Progress Report we have been studying a third topic, the localizability of moving sources. The results of this research are described. The fidelity of a virtual auditory display is critically dependent on precise measurement of the listener''s Head-Related Transfer Functions (HRTFs), which are used to produce the virtual auditory images. We continue to explore methods for improving our HRTF measurement technique. During this reporting period we compared HRTFs measured using our standard open-canal probe tube technique and HRTFs measured with the closed-canal insert microphones from the Crystal River Engineering Snapshot system.

  2. Comparison of Test Procedures and Energy Efficiency Criteria in Selected International Standards & Labeling Programs for Copy Machines, External Power Supplies, LED Displays, Residential Gas Cooktops and Televisions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zheng, Nina; Zhou, Nan; Fridley, David

    2012-03-01

    This report presents a technical review of international minimum energy performance standards (MEPS), voluntary and mandatory energy efficiency labels and test procedures for five products being considered for new or revised MEPS in China: copy machines, external power supply, LED displays, residential gas cooktops and flat-screen televisions. For each product, an overview of the scope of existing international standards and labeling programs, energy values and energy performance metrics and description and detailed summary table of criteria and procedures in major test standards are presented.

  3. Evaluation of stereoscopic display with visual function and interview

    NASA Astrophysics Data System (ADS)

    Okuyama, Fumio

    1999-05-01

    The influence of binocular stereoscopic (3D) television display on the human eye were compared with one of a 2D display, using human visual function testing and interviews. A 40- inch double lenticular display was used for 2D/3D comparison experiments. Subjects observed the display for 30 minutes at a distance 1.0 m, with a combination of 2D material and one of 3D material. The participants were twelve young adults. Main optometric test with visual function measured were visual acuity, refraction, phoria, near vision point, accommodation etc. The interview consisted of 17 questions. Testing procedures were performed just before watching, just after watching, and forty-five minutes after watching. Changes in visual function are characterized as prolongation of near vision point, decrease of accommodation and increase in phoria. 3D viewing interview results show much more visual fatigue in comparison with 2D results. The conclusions are: 1) change in visual function is larger and visual fatigue is more intense when viewing 3D images. 2) The evaluation method with visual function and interview proved to be very satisfactory for analyzing the influence of stereoscopic display on human eye.

  4. ORF phage display to identify cellular proteins with different functions.

    PubMed

    Li, Wei

    2012-09-01

    Open reading frame (ORF) phage display is a new branch of phage display aimed at improving its efficiency to identify cellular proteins with specific binding or functional activities. Despite the success of phage display with antibody libraries and random peptide libraries, phage display with cDNA libraries of cellular proteins identifies a high percentage of non-ORF clones encoding unnatural short peptides with minimal biological implications. This is mainly because of the uncontrollable reading frames of cellular proteins in conventional cDNA libraries. ORF phage display solves this problem by eliminating non-ORF clones to generate ORF cDNA libraries. Here I summarize the procedures of ORF phage display, discuss the factors influencing its efficiency, present examples of its versatile applications, and highlight evidence of its capability of identifying biologically relevant cellular proteins. ORF phage display coupled with different selection strategies is capable of delineating diverse functions of cellular proteins with unique advantages. Copyright © 2012 Elsevier Inc. All rights reserved.

  5. Atomic photoionization in a strong magnetic field

    NASA Astrophysics Data System (ADS)

    Greene, C. H.

    1983-10-01

    The photoionization of hydrogen atoms in a strong magnetic field is formulated as a multichannel problem by representing the asymptotic electron-wave function in cylindrical coordinates. Departures from cylindrical symmetry close to the nucleus are incorporated by an R-matrix treatment at short range, which then merges with standard quantum-defect procedures. The R-matrix calculation utilizes the eigenchannel approach, recast in noniterative form. At the field strength treated here, B = 4.7 x 10 to the 9th G, the photoionization cross section displays narrow 'autoionizing' resonances near the excited Landau thresholds.

  6. New extension software modules to enhance searching and display of transcriptome data in Tripal databases

    PubMed Central

    Chen, Ming; Henry, Nathan; Almsaeed, Abdullah; Zhou, Xiao; Wegrzyn, Jill; Ficklin, Stephen

    2017-01-01

    Abstract Tripal is an open source software package for developing biological databases with a focus on genetic and genomic data. It consists of a set of core modules that deliver essential functions for loading and displaying data records and associated attributes including organisms, sequence features and genetic markers. Beyond the core modules, community members are encouraged to contribute extension modules to build on the Tripal core and to customize Tripal for individual community needs. To expand the utility of the Tripal software system, particularly for RNASeq data, we developed two new extension modules. Tripal Elasticsearch enables fast, scalable searching of the entire content of a Tripal site as well as the construction of customized advanced searches of specific data types. We demonstrate the use of this module for searching assembled transcripts by functional annotation. A second module, Tripal Analysis Expression, houses and displays records from gene expression assays such as RNA sequencing. This includes biological source materials (biomaterials), gene expression values and protocols used to generate the data. In the case of an RNASeq experiment, this would reflect the individual organisms and tissues used to produce sequencing libraries, the normalized gene expression values derived from the RNASeq data analysis and a description of the software or code used to generate the expression values. The module will load data from common flat file formats including standard NCBI Biosample XML. Data loading, display options and other configurations can be controlled by authorized users in the Drupal administrative backend. Both modules are open source, include usage documentation, and can be found in the Tripal organization’s GitHub repository. Database URL: Tripal Elasticsearch module: https://github.com/tripal/tripal_elasticsearch Tripal Analysis Expression module: https://github.com/tripal/tripal_analysis_expression PMID:29220446

  7. Raster Scan Computer Image Generation (CIG) System Based On Refresh Memory

    NASA Astrophysics Data System (ADS)

    Dichter, W.; Doris, K.; Conkling, C.

    1982-06-01

    A full color, Computer Image Generation (CIG) raster visual system has been developed which provides a high level of training sophistication by utilizing advanced semiconductor technology and innovative hardware and firmware techniques. Double buffered refresh memory and efficient algorithms eliminate the problem of conventional raster line ordering by allowing the generated image to be stored in a random fashion. Modular design techniques and simplified architecture provide significant advantages in reduced system cost, standardization of parts, and high reliability. The major system components are a general purpose computer to perform interfacing and data base functions; a geometric processor to define the instantaneous scene image; a display generator to convert the image to a video signal; an illumination control unit which provides final image processing; and a CRT monitor for display of the completed image. Additional optional enhancements include texture generators, increased edge and occultation capability, curved surface shading, and data base extensions.

  8. A dynamic response and eye scanning data base useful in the development of theories and methods for the description of control/display relationships

    NASA Technical Reports Server (NTRS)

    Klein, R.

    1972-01-01

    A set of specially prepared digital tapes is reported which contain synchronized measurements of pilot scanning behavior, control response, and vehicle response obtained during instrument landing system approaches made in a fixed-base DC-8 transport simulator. The objective of the master tape is to provide a common data base which can be used by the research community to test theories, models, and methods for describing and analyzing control/display relations and interactions. The experimental conditions and tasks used to obtain the data and the detailed format of the tapes are described. Conventional instrument panel and controls were used, with simulated vertical gust and glide slope beam bend forcing functions. Continuous pilot eye fixations and scan traffic on the panel were measured. Both flight director and standard localizer/glide slope types of approaches were made, with both fixed and variable instrument range sensitivities.

  9. Reproduction of auditory and visual standards in monochannel cochlear implant users.

    PubMed

    Kanabus, Magdalena; Szelag, Elzbieta; Kolodziejczyk, Iwona; Szuchnik, Joanna

    2004-01-01

    The temporal reproduction of standard durations ranging from 1 to 9 seconds was investigated in monochannel cochlear implant (CI) users and in normally hearing subjects for the auditory and visual modality. The results showed that the pattern of performance in patients depended on their level of auditory comprehension. Results for CI users, who displayed relatively good auditory comprehension, did not differ from that of normally hearing subjects for both modalities. Patients with poor auditory comprehension significantly overestimated shorter auditory standards (1, 1.5 and 2.5 s), compared to both patients with good comprehension and controls. For the visual modality the between-group comparisons were not significant. These deficits in the reproduction of auditory standards were explained in accordance with both the attentional-gate model and the role of working memory in prospective time judgment. The impairments described above can influence the functioning of the temporal integration mechanism that is crucial for auditory speech comprehension on the level of words and phrases. We postulate that the deficits in time reproduction of short standards may be one of the possible reasons for poor speech understanding in monochannel CI users.

  10. Multifunctional recombinant phycobiliprotein-based fluorescent constructs and phycobilisome display

    DOEpatents

    Glazer, Alexander N.; Cai, Yuping

    2007-01-30

    The invention provides multifunctional fusion constructs which are rapidly incorporated into a macromolecular structure such as a phycobilisome such that the fusion proteins are separated from one another and unable to self-associate. The invention provides methods and compositions for displaying a functional polypeptide domain on an oligomeric phycobiliprotein, including fusion proteins comprising a functional displayed domain and a functional phycobiliprotein domain incorporated in a functional oligomeric phycobiliprotein. The fusion proteins provide novel specific labeling reagents.

  11. Multifunctional recombinant phycobiliprotein-based fluorescent constructs and phycobilisome display

    DOEpatents

    Glazer, Alexander N.; Cai, Yuping

    2007-02-13

    The invention provides multifunctional fusion constructs which are rapidly incorporated into a macromolecular structure such as a phycobilisome such that the fusion proteins are separated from one another and unable to self-associate. The invention provides methods and compositions for displaying a functional polypeptide domain on an oligomeric phycobiliprotein. including fusion proteins comprising a functional displayed domain and a functional phycobiliprotein domain incorporated in a functional oligomeric phycobiliprotein. The fusion proteins provide novel specific labeling reagents.

  12. Multifunctional recombinant phycobiliprotein-based fluorescent constructs and phycobilisome display

    DOEpatents

    Glazer, Alexander N.; Cai, Yuping

    2003-11-18

    The invention provides multifunctional fusion constructs which are rapidly incorporated into a macromolecular structure such as a phycobilisome such that the fusion proteins are separated from one another and unable to self-associate. The invention provides methods and compositions for displaying a functional polypeptide domain on an oligomeric phycobiliprotein, including fusion proteins comprising a functional displayed domain and a functional phycobiliprotein domain incorporated in a functional oligomeric phycobiliprotein. The fusion proteins provide novel specific labeling reagents.

  13. Method and apparatus for calibrating a tiled display

    NASA Technical Reports Server (NTRS)

    Chen, Chung-Jen (Inventor); Johnson, Michael J. (Inventor); Chandrasekhar, Rajesh (Inventor)

    2001-01-01

    A display system that can be calibrated and re-calibrated with a minimal amount of manual intervention. To accomplish this, one or more cameras are provided to capture an image of the display screen. The resulting captured image is processed to identify any non-desirable characteristics, including visible artifacts such as seams, bands, rings, etc. Once the non-desirable characteristics are identified, an appropriate transformation function is determined. The transformation function is used to pre-warp the input video signal that is provided to the display such that the non-desirable characteristics are reduced or eliminated from the display. The transformation function preferably compensates for spatial non-uniformity, color non-uniformity, luminance non-uniformity, and other visible artifacts.

  14. Visualizing bacterial tRNA identity determinants and antideterminants using function logos and inverse function logos

    PubMed Central

    Freyhult, Eva; Moulton, Vincent; Ardell, David H.

    2006-01-01

    Sequence logos are stacked bar graphs that generalize the notion of consensus sequence. They employ entropy statistics very effectively to display variation in a structural alignment of sequences of a common function, while emphasizing its over-represented features. Yet sequence logos cannot display features that distinguish functional subclasses within a structurally related superfamily nor do they display under-represented features. We introduce two extensions to address these needs: function logos and inverse logos. Function logos display subfunctions that are over-represented among sequences carrying a specific feature. Inverse logos generalize both sequence logos and function logos by displaying under-represented, rather than over-represented, features or functions in structural alignments. To make inverse logos, a compositional inverse is applied to the feature or function frequency distributions before logo construction, where a compositional inverse is a mathematical transform that makes common features or functions rare and vice versa. We applied these methods to a database of structurally aligned bacterial tDNAs to create highly condensed, birds-eye views of potentially all so-called identity determinants and antideterminants that confer specific amino acid charging or initiator function on tRNAs in bacteria. We recovered both known and a few potentially novel identity elements. Function logos and inverse logos are useful tools for exploratory bioinformatic analysis of structure–function relationships in sequence families and superfamilies. PMID:16473848

  15. "TPSX: Thermal Protection System Expert and Material Property Database"

    NASA Technical Reports Server (NTRS)

    Squire, Thomas H.; Milos, Frank S.; Rasky, Daniel J. (Technical Monitor)

    1997-01-01

    The Thermal Protection Branch at NASA Ames Research Center has developed a computer program for storing, organizing, and accessing information about thermal protection materials. The program, called Thermal Protection Systems Expert and Material Property Database, or TPSX, is available for the Microsoft Windows operating system. An "on-line" version is also accessible on the World Wide Web. TPSX is designed to be a high-quality source for TPS material properties presented in a convenient, easily accessible form for use by engineers and researchers in the field of high-speed vehicle design. Data can be displayed and printed in several formats. An information window displays a brief description of the material with properties at standard pressure and temperature. A spread sheet window displays complete, detailed property information. Properties which are a function of temperature and/or pressure can be displayed as graphs. In any display the data can be converted from English to SI units with the click of a button. Two material databases included with TPSX are: 1) materials used and/or developed by the Thermal Protection Branch at NASA Ames Research Center, and 2) a database compiled by NASA Johnson Space Center 9JSC). The Ames database contains over 60 advanced TPS materials including flexible blankets, rigid ceramic tiles, and ultra-high temperature ceramics. The JSC database contains over 130 insulative and structural materials. The Ames database is periodically updated and expanded as required to include newly developed materials and material property refinements.

  16. Development of display design and command usage guidelines for Spacelab experiment computer applications

    NASA Technical Reports Server (NTRS)

    Dodson, D. W.; Shields, N. L., Jr.

    1979-01-01

    Individual Spacelab experiments are responsible for developing their CRT display formats and interactive command scenarios for payload crew monitoring and control of experiment operations via the Spacelab Data Display System (DDS). In order to enhance crew training and flight operations, it was important to establish some standardization of the crew/experiment interface among different experiments by providing standard methods and techniques for data presentation and experiment commanding via the DDS. In order to establish optimum usage guidelines for the Spacelab DDS, the capabilities and limitations of the hardware and Experiment Computer Operating System design had to be considered. Since the operating system software and hardware design had already been established, the Display and Command Usage Guidelines were constrained to the capabilities of the existing system design. Empirical evaluations were conducted on a DDS simulator to determine optimum operator/system interface utilization of the system capabilities. Display parameters such as information location, display density, data organization, status presentation and dynamic update effects were evaluated in terms of response times and error rates.

  17. Designing display primaries with currently available light sources for UHDTV wide-gamut system colorimetry.

    PubMed

    Masaoka, Kenichiro; Nishida, Yukihiro; Sugawara, Masayuki

    2014-08-11

    The wide-gamut system colorimetry has been standardized for ultra-high definition television (UHDTV). The chromaticities of the primaries are designed to lie on the spectral locus to cover major standard system colorimetries and real object colors. Although monochromatic light sources are required for a display to perfectly fulfill the system colorimetry, highly saturated emission colors using recent quantum dot technology may effectively achieve the wide gamut. This paper presents simulation results on the chromaticities of highly saturated non-monochromatic light sources and gamut coverage of real object colors to be considered in designing wide-gamut displays with color filters for the UHDTV.

  18. Free viewpoint TV and its international standardization

    NASA Astrophysics Data System (ADS)

    Tanimoto, Masayuki

    2009-05-01

    We have developed a new type of television named FTV (Free-viewpoint TV). FTV is an innovative visual media that enables us to view a 3D scene by freely changing our viewpoints. We proposed the concept of FTV and constructed the world's first real-time system including the complete chain of operation from image capture to display. We also realized FTV on a single PC and FTV with free listening-point audio. FTV is based on the ray-space method that represents one ray in real space with one point in the ray-space. We have also developed new type of ray capture and display technologies such as a 360-degree mirror-scan ray capturing system and a 360 degree ray-reproducing display. MPEG regarded FTV as the most challenging 3D media and started the international standardization activities of FTV. The first phase of FTV is MVC (Multi-view Video Coding) and the second phase is 3DV (3D Video). MVC was completed in March 2009. 3DV is a standard that targets serving a variety of 3D displays. It will be completed within the next two years.

  19. Automated system function allocation and display format: Task information processing requirements

    NASA Technical Reports Server (NTRS)

    Czerwinski, Mary P.

    1993-01-01

    An important consideration when designing the interface to an intelligent system concerns function allocation between the system and the user. The display of information could be held constant, or 'fixed', leaving the user with the task of searching through all of the available information, integrating it, and classifying the data into a known system state. On the other hand, the system, based on its own intelligent diagnosis, could display only relevant information in order to reduce the user's search set. The user would still be left the task of perceiving and integrating the data and classifying it into the appropriate system state. Finally, the system could display the patterns of data. In this scenario, the task of integrating the data is carried out by the system, and the user's information processing load is reduced, leaving only the tasks of perception and classification of the patterns of data. Humans are especially adept at this form of display processing. Although others have examined the relative effectiveness of alphanumeric and graphical display formats, it is interesting to reexamine this issue together with the function allocation problem. Currently, Johnson Space Center is the test site for an intelligent Thermal Control System (TCS), TEXSYS, being tested for use with Space Station Freedom. Expert TCS engineers, as well as novices, were asked to classify several displays of TEXSYS data into various system states (including nominal and anomalous states). Three different display formats were used: fixed, subset, and graphical. The hypothesis tested was that the graphical displays would provide for fewer errors and faster classification times by both experts and novices, regardless of the kind of system state represented within the display. The subset displays were hypothesized to be the second most effective display format/function allocation condition, based on the fact that the search set is reduced in these displays. Both the subset and the graphic display conditions were hypothesized to be processed more efficiently than the fixed display conditions.

  20. Functional Cell Surface Display and Controlled Secretion of Diverse Agarolytic Enzymes by Escherichia coli with a Novel Ligation-Independent Cloning Vector Based on the Autotransporter YfaL

    PubMed Central

    Ko, Hyeok-Jin; Park, Eunhye; Song, Joseph; Yang, Taek Ho; Lee, Hee Jong; Kim, Kyoung Heon

    2012-01-01

    Autotransporters have been employed as the anchoring scaffold for cell surface display by replacing their passenger domains with heterologous proteins to be displayed. We adopted an autotransporter (YfaL) of Escherichia coli for the cell surface display system. The critical regions in YfaL for surface display were identified for the construction of a ligation-independent cloning (LIC)-based display system. The designed system showed no detrimental effect on either the growth of the host cell or overexpressing heterologous proteins on the cell surface. We functionally displayed monomeric red fluorescent protein (mRFP1) as a reporter protein and diverse agarolytic enzymes from Saccharophagus degradans 2-40, including Aga86C and Aga86E, which previously had failed to be functional expressed. The system could display different sizes of proteins ranging from 25.3 to 143 kDa. We also attempted controlled release of the displayed proteins by incorporating a tobacco etch virus protease cleavage site into the C termini of the displayed proteins. The maximum level of the displayed protein was 6.1 × 104 molecules per a single cell, which corresponds to 5.6% of the entire cell surface of actively growing E. coli. PMID:22344647

  1. Solving bezel reliability and CRT obsolescence

    NASA Astrophysics Data System (ADS)

    Schwartz, Richard J.; Bowen, Arlen R.; Knowles, Terry

    2003-09-01

    Scientific Research Corporation designed a Smart Multi-Function Color Display with Positive Pilot Feedback under the funding of an U. S. Navy Small Business Innovative Research program. The Smart Multi-Function Color Display can replace the obsolete monochrome Cathode Ray Tube display currently on the T-45C aircraft built by Boeing. The design utilizes a flat panel color Active Matrix Liquid Crystal Display and TexZec's patented Touch Thru Metal bezel technology providing both visual and biomechanical feedback to the pilot in a form, fit, and function replacement to the current T-45C display. Use of an existing color AMLCD, requires the least adaptation to fill the requirements of this application, thereby minimizing risk associated with developing a new display technology and maximizing the investment in improved user interface technology. The improved user interface uses TexZec's Touch Thru Metal technology to eliminate all of the moving parts that traditionally have limited Mean-Time-Between-Failure. The touch detection circuit consists of Commercial-Off-The-Shelf components, creating touch detection circuitry, which is simple and durable. This technology provides robust switch activation and a high level of environmental immunity, both mechanical and electrical. Replacement of all the T-45C multi-function displays with this design will improve the Mean-Time-Between-Failure and drastically reduce display life cycle costs. The design methodology described in this paper can be adapted to any new or replacement display.

  2. Multimedial data base and management system for self-education and testing the students' knowledge on pathomorphology.

    PubMed

    Szymaś, J; Gawroński, M

    1993-01-01

    The composition assumed our experience in creating and using multimedial data base of examination questions and management system, which is used for. This system is implemented on microcomputers compatible with IBM PC and works in network system Net Ware 3.11. The test questions exceeded 2000 until now. The packet consists of the two functionally individual programs: ASSISTANT, which is the administrator for the databases, and EXAMINATOR which is the executive program. This system enables to use text files and add images to each question, which are adjusted to display on standard graphics devices (VGA). Standard format of the notation files enables to elaborate the results in order to estimate the scale of answers and to find correlations between the results.

  3. Pentacene-based organic thin film transistors, integrated circuits, and active matrix displays on polymeric substrates

    NASA Astrophysics Data System (ADS)

    Sheraw, Christopher Duncan

    2003-10-01

    Organic thin film transistors are attractive candidates for a variety of low cost, large area commercial electronics including smart cards, RF identification tags, and flat panel displays. Of particular interest are high performance organic thin film transistors (TFTs) that can be fabricated on flexible polymeric substrates allowing low-cost, lightweight, rugged electronics such as flexible active matrix displays. This thesis reports pentacene organic thin film transistors fabricated on flexible polymeric substrates with record performance, the fastest photolithographically patterned organic TFT integrated circuits on polymeric substrates reported to date, and the fabrication of the organic TFT backplanes used to build the first organic TFT-driven active matrix liquid crystal display (AMLCD), also the first AMLCD on a flexible substrate, ever reported. In addition, the first investigation of functionalized pentacene derivatives used as the active layer in organic thin film transistors is reported. A low temperature (<110°C) process technology was developed allowing the fabrication of high performance organic TFTs, integrated circuits, and large TFT arrays on flexible polymeric substrates. This process includes the development of a novel water-based photolithographic active layer patterning process using polyvinyl alcohol that allows the patterning of organic semiconductor materials for elimination of active layer leakage current without causing device degradation. The small molecule aromatic hydrocarbon pentacene was used as the active layer material to fabricate organic TFTs on the polymeric material polyethylene naphthalate with field-effect mobility as large as 2.1 cm2/V-s and on/off current ratio of 108. These are the best values reported for organic TFTs on polymeric substrates and comparable to organic TFTs on rigid substrates. Analog and digital integrated circuits were also fabricated on polymeric substrates using pentacene TFTs with propagation delay as low as 38 musec and clocked digital circuits that operated at 1.1 kHz. These are the fastest photolithographically patterned organic TFT circuits on polymeric substrates reported to date. Finally, 16 x 16 pentacene TFT pixel arrays were fabricated on polymeric substrates and integrated with polymer dispersed liquid crystal to build an AMLCD. The pixel arrays showed good optical response to changing data signals when standard quarter-VGA display waveforms were applied. This result marks the first organic TFT-driven active matrix liquid crystal display ever reported as well as the first active matrix liquid crystal display on a flexible polymeric substrate. Lastly, functionalized pentacene derivatives were used as the active layer in organic thin film transistor materials. Functional groups were added to the pentacene molecule to influence the molecular ordering so that the amount of pi-orbital overlap would be increased allowing the potential for improved field-effect mobility. The functionalization of these materials also improves solubility allowing for the possibility of solution-processed devices and increased oxidative stability. Organic thin film transistors were fabricated using five different functionalized pentacene active layers. Devices based on the pentacene derivative triisopropylsilyl pentacene were found to have the best performance with field-effect mobility as large as 0.4 cm 2/V-s.

  4. Improvement of the user interface of multimedia applications by automatic display layout

    NASA Astrophysics Data System (ADS)

    Lueders, Peter; Ernst, Rolf

    1995-03-01

    Multimedia research has mainly focussed on real-time data capturing and display combined with compression, storage and transmission of these data. However, there is another problem considering real-time selecting and arranging a possibly large amount of data from multiple media on the computer screen together with textual and graphical data of regular software. This problem has already been known from complex software systems, such as CASE and hypertest, and will even be aggravated in multimedia systems. The aim of our work is to alleviate the user from the burden of continuously selecting, placing and sizing windows and their contents, but without introducing solutions limited to only few applications. We present an experimental system which controls the computer screen contents and layouts, directed by a user and/or tool provided information filter and prioritization. To be application independent, the screen layout is based on general layout optimization algorithms adapted from the VLSI layout which are controlled by application specific objective functions. In this paper, we discuss the problems of a comprehensible screen layout including the stability of optical information in time, the information filtering, the layout algorithms and the adaptation of the objective function to include a specific application. We give some examples of different standard applications with layout problems ranging from hierarchical graph layout to window layout. The results show that the automatic tool independent display layout will be possible in a real time interactive environment.

  5. Different correlation patterns of cholinergic and GABAergic interneurons with striatal projection neurons

    PubMed Central

    Adler, Avital; Katabi, Shiran; Finkes, Inna; Prut, Yifat; Bergman, Hagai

    2013-01-01

    The striatum is populated by a single projection neuron group, the medium spiny neurons (MSNs), and several groups of interneurons. Two of the electrophysiologically well-characterized striatal interneuron groups are the tonically active neurons (TANs), which are presumably cholinergic interneurons, and the fast spiking interneurons (FSIs), presumably parvalbumin (PV) expressing GABAergic interneurons. To better understand striatal processing it is thus crucial to define the functional relationship between MSNs and these interneurons in the awake and behaving animal. We used multiple electrodes and standard physiological methods to simultaneously record MSN spiking activity and the activity of TANs or FSIs from monkeys engaged in a classical conditioning paradigm. All three cell populations were highly responsive to the behavioral task. However, they displayed different average response profiles and a different degree of response synchronization (signal correlation). TANs displayed the most transient and synchronized response, MSNs the most diverse and sustained response and FSIs were in between on both parameters. We did not find evidence for direct monosynaptic connectivity between the MSNs and either the TANs or the FSIs. However, while the cross correlation histograms of TAN to MSN pairs were flat, those of FSI to MSN displayed positive asymmetrical broad peaks. The FSI-MSN correlogram profile implies that the spikes of MSNs follow those of FSIs and both are driven by a common, most likely cortical, input. Thus, the two populations of striatal interneurons are probably driven by different afferents and play complementary functional roles in the physiology of the striatal microcircuit. PMID:24027501

  6. The savant syndrome: intellectual impairment and exceptional skill.

    PubMed

    Miller, L K

    1999-01-01

    Occasionally, people with developmental disability display skills at a level inconsistent with their general intellectual functioning, so-called "savant" behavior. Studies of savant behavior are reviewed to determine their relevance to notions about the importance of general intellective functions in the development of exceptional skill. It is concluded that (a) the skill exhibited by savants shares many characteristics with that in people without disability, (b) the skill is usually accompanied by normative levels of performance on at least some subtests of standardized measures of cognitive achievement, and (c) it is unclear whether savants have distinctive cognitive strengths or motivational dispositions, though their relative prevalence among people with certain kinds of disability suggests predisposing constraints. The author proposes that these skills typically reflect highly elaborated preconceptual representational systems.

  7. Perception of 'Back-Channeling' Nonverbal Feedback in Musical Duo Improvisation.

    PubMed

    Moran, Nikki; Hadley, Lauren V; Bader, Maria; Keller, Peter E

    2015-01-01

    In witnessing face-to-face conversation, observers perceive authentic communication according to the social contingency of nonverbal feedback cues ('back-channeling') by non-speaking interactors. The current study investigated the generality of this function by focusing on nonverbal communication in musical improvisation. A perceptual experiment was conducted to test whether observers can reliably identify genuine versus fake (mismatched) duos from musicians' nonverbal cues, and how this judgement is affected by observers' musical background and rhythm perception skill. Twenty-four musicians were recruited to perform duo improvisations, which included solo episodes, in two styles: standard jazz (where rhythm is based on a regular pulse) or free improvisation (where rhythm is non-pulsed). The improvisations were recorded using a motion capture system to generate 16 ten-second point-light displays (with audio) of the soloist and the silent non-soloing musician ('back-channeler'). Sixteen further displays were created by splicing soloists with back-channelers from different duos. Participants (N = 60) with various musical backgrounds were asked to rate the point-light displays as either real or fake. Results indicated that participants were sensitive to the real/fake distinction in the free improvisation condition independently of musical experience. Individual differences in rhythm perception skill did not account for performance in the free condition, but were positively correlated with accuracy in the standard jazz condition. These findings suggest that the perception of back-channeling in free improvisation is not dependent on music-specific skills but is a general ability. The findings invite further study of the links between interpersonal dynamics in conversation and musical interaction.

  8. Perception of ‘Back-Channeling’ Nonverbal Feedback in Musical Duo Improvisation

    PubMed Central

    Moran, Nikki; Hadley, Lauren V.; Bader, Maria; Keller, Peter E.

    2015-01-01

    In witnessing face-to-face conversation, observers perceive authentic communication according to the social contingency of nonverbal feedback cues (‘back-channeling’) by non-speaking interactors. The current study investigated the generality of this function by focusing on nonverbal communication in musical improvisation. A perceptual experiment was conducted to test whether observers can reliably identify genuine versus fake (mismatched) duos from musicians’ nonverbal cues, and how this judgement is affected by observers’ musical background and rhythm perception skill. Twenty-four musicians were recruited to perform duo improvisations, which included solo episodes, in two styles: standard jazz (where rhythm is based on a regular pulse) or free improvisation (where rhythm is non-pulsed). The improvisations were recorded using a motion capture system to generate 16 ten-second point-light displays (with audio) of the soloist and the silent non-soloing musician (‘back-channeler’). Sixteen further displays were created by splicing soloists with back-channelers from different duos. Participants (N = 60) with various musical backgrounds were asked to rate the point-light displays as either real or fake. Results indicated that participants were sensitive to the real/fake distinction in the free improvisation condition independently of musical experience. Individual differences in rhythm perception skill did not account for performance in the free condition, but were positively correlated with accuracy in the standard jazz condition. These findings suggest that the perception of back-channeling in free improvisation is not dependent on music-specific skills but is a general ability. The findings invite further study of the links between interpersonal dynamics in conversation and musical interaction. PMID:26086593

  9. Display nonlinearity in digital image processing for visual communications

    NASA Astrophysics Data System (ADS)

    Peli, Eli

    1992-11-01

    The luminance emitted from a cathode ray tube (CRT) display is a nonlinear function (the gamma function) of the input video signal voltage. In most analog video systems, compensation for this nonlinear transfer function is implemented in the camera amplifiers. When CRT displays are used to present psychophysical stimuli in vision research, the specific display nonlinearity usually is measured and accounted for to ensure that the luminance of each pixel in the synthetic image property represents the intended value. However, when using digital image processing, the linear analog-to-digital converters store a digital image that is nonlinearly related to the displayed or recorded image. The effect of this nonlinear transformation on a variety of image-processing applications used in visual communications is described.

  10. Display nonlinearity in digital image processing for visual communications

    NASA Astrophysics Data System (ADS)

    Peli, Eli

    1991-11-01

    The luminance emitted from a cathode ray tube, (CRT) display is a nonlinear function (the gamma function) of the input video signal voltage. In most analog video systems, compensation for this nonlinear transfer function is implemented in the camera amplifiers. When CRT displays are used to present psychophysical stimuli in vision research, the specific display nonlinearity usually is measured and accounted for to ensure that the luminance of each pixel in the synthetic image properly represents the intended value. However, when using digital image processing, the linear analog-to-digital converters store a digital image that is nonlinearly related to the displayed or recorded image. This paper describes the effect of this nonlinear transformation on a variety of image-processing applications used in visual communications.

  11. A portable high-definition electronic endoscope based on embedded system

    NASA Astrophysics Data System (ADS)

    Xu, Guang; Wang, Liqiang; Xu, Jin

    2012-11-01

    This paper presents a low power and portable highdefinition (HD) electronic endoscope based on CortexA8 embedded system. A 1/6 inch CMOS image sensor is used to acquire HD images with 1280 *800 pixels. The camera interface of A8 is designed to support images of various sizes and support multiple inputs of video format such as ITUR BT601/ 656 standard. Image rotation (90 degrees clockwise) and image process functions are achieved by CAMIF. The decode engine of the processor plays back or records HD videos at speed of 30 frames per second, builtin HDMI interface transmits high definition images to the external display. Image processing procedures such as demosaicking, color correction and auto white balance are realized on the A8 platform. Other functions are selected through OSD settings. An LCD panel displays the real time images. The snapshot pictures or compressed videos are saved in an SD card or transmited to a computer through USB interface. The size of the camera head is 4×4.8×15 mm with more than 3 meters working distance. The whole endoscope system can be powered by a lithium battery, with the advantages of miniature, low cost and portability.

  12. Introduction to the National Information Display Laboratory

    NASA Technical Reports Server (NTRS)

    Carlson, Curtis R.

    1992-01-01

    The goals of the National Information Display Laboratory (NIDL) are described in viewgraph form. The NIDL is a Center of Excellence in softcopy technology with the overall goal to develop new ways to satisfy government information needs through aggressive user support and the development of advanced technology. Government/industry/academia participation, standards development, and various display technologies are addressed.

  13. Reexamination of color vision standards, part III : analysis of the effects of color vision deficiencies in using ATC displays : final report.

    DOT National Transportation Integrated Search

    2006-05-01

    The purpose of this report is to assess the effect of color use in air traffic control (ATC) displays for users who have color vision deficiencies, denoted as color deficient (CD). At present, color is extensively used in many ATC displays, while the...

  14. Two dimensional eye tracking: Sampling rate of forcing function

    NASA Technical Reports Server (NTRS)

    Hornseth, J. P.; Monk, D. L.; Porterfield, J. L.; Mcmurry, R. L.

    1978-01-01

    A study was conducted to determine the minimum update rate of a forcing function display required for the operator to approximate the tracking performance obtained on a continuous display. In this study, frequency analysis was used to determine whether there was an associated change in the transfer function characteristics of the operator. It was expected that as the forcing function display update rate was reduced, from 120 to 15 samples per second, the operator's response to the high frequency components of the forcing function would show a decrease in gain, an increase in phase lag, and a decrease in coherence.

  15. Correlation between Visual Field Index and Other Functional and Structural Measures in Glaucoma Patients and Suspects.

    PubMed

    Iutaka, Natalia A; Grochowski, Rubens A; Kasahara, Niro

    2017-01-01

    To evaluate the correlation between visual field index (VFI) and both structural and functional measures of the optic disc in primary open angle glaucoma patients and suspects. In this retrospective study, 162 glaucoma patients and suspects underwent standard automated perimetry (SAP), retinography, and retinal nerve fiber layer (RNFL) measurement. The optic disc was stratified according to the vertical cup/disc ratio (C/D) and sorted by the disc damage likelihood scale (DDLS). RNFL was measured with the optical coherence tomography. The VFI perimetry was correlated with the mean deviation (MD) and pattern standard deviation (PSD) obtained by SAP, and structural parameters by Pearson's correlation coefficients. VFI displayed strong correlation with MD ( R = 0.959) and PSD ( R = -0.744). The linear correlations between VFI and structural measures including C/D ( R = -0.179, P = 0.012), DDLS ( R = -0.214, P = 0.006), and RNFL ( R = 0.416, P < 0.001) were weak but statistically significant. VFI showed a strong correlation with MD and PSD but demonstrated a weak correlation with structural measures. It can possibly be used as a marker for functional impairment severity in patients with glaucoma.

  16. Terminal Information Processing System (TIPS) Consolidated CAB Display (CCD) Comparative Analysis.

    DTIC Science & Technology

    1982-04-01

    Barometric pressure 3. Center field wind speed, direction and gusts 4. Runway visual range 5. Low-level wind shear 6. Vortex advisory 7. Runway equipment...PASSWORD Command (standard user) u. PAUSE Command (standard user) v. PMSG Command (standard user) w. PPD Command (standard user) x. PURGE Command (standard

  17. Advanced Transport Operating System (ATOPS) color displays software description microprocessor system

    NASA Technical Reports Server (NTRS)

    Slominski, Christopher J.; Plyler, Valerie E.; Dickson, Richard W.

    1992-01-01

    This document describes the software created for the Sperry Microprocessor Color Display System used for the Advanced Transport Operating Systems (ATOPS) project on the Transport Systems Research Vehicle (TSRV). The software delivery known as the 'baseline display system', is the one described in this document. Throughout this publication, module descriptions are presented in a standardized format which contains module purpose, calling sequence, detailed description, and global references. The global reference section includes procedures and common variables referenced by a particular module. The system described supports the Research Flight Deck (RFD) of the TSRV. The RFD contains eight cathode ray tubes (CRTs) which depict a Primary Flight Display, Navigation Display, System Warning Display, Takeoff Performance Monitoring System Display, and Engine Display.

  18. Optical See-Through Head Mounted Display Direct Linear Transformation Calibration Robustness in the Presence of User Alignment Noise

    NASA Technical Reports Server (NTRS)

    Axholt, Magnus; Skoglund, Martin; Peterson, Stephen D.; Cooper, Matthew D.; Schoen, Thomas B.; Gustafsson, Fredrik; Ynnerman, Anders; Ellis, Stephen R.

    2010-01-01

    Augmented Reality (AR) is a technique by which computer generated signals synthesize impressions that are made to coexist with the surrounding real world as perceived by the user. Human smell, taste, touch and hearing can all be augmented, but most commonly AR refers to the human vision being overlaid with information otherwise not readily available to the user. A correct calibration is important on an application level, ensuring that e.g. data labels are presented at correct locations, but also on a system level to enable display techniques such as stereoscopy to function properly [SOURCE]. Thus, vital to AR, calibration methodology is an important research area. While great achievements already have been made, there are some properties in current calibration methods for augmenting vision which do not translate from its traditional use in automated cameras calibration to its use with a human operator. This paper uses a Monte Carlo simulation of a standard direct linear transformation camera calibration to investigate how user introduced head orientation noise affects the parameter estimation during a calibration procedure of an optical see-through head mounted display.

  19. Sleep: An Open-Source Python Software for Visualization, Analysis, and Staging of Sleep Data

    PubMed Central

    Combrisson, Etienne; Vallat, Raphael; Eichenlaub, Jean-Baptiste; O'Reilly, Christian; Lajnef, Tarek; Guillot, Aymeric; Ruby, Perrine M.; Jerbi, Karim

    2017-01-01

    We introduce Sleep, a new Python open-source graphical user interface (GUI) dedicated to visualization, scoring and analyses of sleep data. Among its most prominent features are: (1) Dynamic display of polysomnographic data, spectrogram, hypnogram and topographic maps with several customizable parameters, (2) Implementation of several automatic detection of sleep features such as spindles, K-complexes, slow waves, and rapid eye movements (REM), (3) Implementation of practical signal processing tools such as re-referencing or filtering, and (4) Display of main descriptive statistics including publication-ready tables and figures. The software package supports loading and reading raw EEG data from standard file formats such as European Data Format, in addition to a range of commercial data formats. Most importantly, Sleep is built on top of the VisPy library, which provides GPU-based fast and high-level visualization. As a result, it is capable of efficiently handling and displaying large sleep datasets. Sleep is freely available (http://visbrain.org/sleep) and comes with sample datasets and an extensive documentation. Novel functionalities will continue to be added and open-science community efforts are expected to enhance the capacities of this module. PMID:28983246

  20. Sleep: An Open-Source Python Software for Visualization, Analysis, and Staging of Sleep Data.

    PubMed

    Combrisson, Etienne; Vallat, Raphael; Eichenlaub, Jean-Baptiste; O'Reilly, Christian; Lajnef, Tarek; Guillot, Aymeric; Ruby, Perrine M; Jerbi, Karim

    2017-01-01

    We introduce Sleep, a new Python open-source graphical user interface (GUI) dedicated to visualization, scoring and analyses of sleep data. Among its most prominent features are: (1) Dynamic display of polysomnographic data, spectrogram, hypnogram and topographic maps with several customizable parameters, (2) Implementation of several automatic detection of sleep features such as spindles, K-complexes, slow waves, and rapid eye movements (REM), (3) Implementation of practical signal processing tools such as re-referencing or filtering, and (4) Display of main descriptive statistics including publication-ready tables and figures. The software package supports loading and reading raw EEG data from standard file formats such as European Data Format, in addition to a range of commercial data formats. Most importantly, Sleep is built on top of the VisPy library, which provides GPU-based fast and high-level visualization. As a result, it is capable of efficiently handling and displaying large sleep datasets. Sleep is freely available (http://visbrain.org/sleep) and comes with sample datasets and an extensive documentation. Novel functionalities will continue to be added and open-science community efforts are expected to enhance the capacities of this module.

  1. Application Reuse Library for Software, Requirements, and Guidelines

    NASA Technical Reports Server (NTRS)

    Malin, Jane T.; Thronesbery, Carroll

    1994-01-01

    Better designs are needed for expert systems and other operations automation software, for more reliable, usable and effective human support. A prototype computer-aided Application Reuse Library shows feasibility of supporting concurrent development and improvement of advanced software by users, analysts, software developers, and human-computer interaction experts. Such a library expedites development of quality software, by providing working, documented examples, which support understanding, modification and reuse of requirements as well as code. It explicitly documents and implicitly embodies design guidelines, standards and conventions. The Application Reuse Library provides application modules with Demo-and-Tester elements. Developers and users can evaluate applicability of a library module and test modifications, by running it interactively. Sub-modules provide application code and displays and controls. The library supports software modification and reuse, by providing alternative versions of application and display functionality. Information about human support and display requirements is provided, so that modifications will conform to guidelines. The library supports entry of new application modules from developers throughout an organization. Example library modules include a timer, some buttons and special fonts, and a real-time data interface program. The library prototype is implemented in the object-oriented G2 environment for developing real-time expert systems.

  2. Soldier-worn augmented reality system for tactical icon visualization

    NASA Astrophysics Data System (ADS)

    Roberts, David; Menozzi, Alberico; Clipp, Brian; Russler, Patrick; Cook, James; Karl, Robert; Wenger, Eric; Church, William; Mauger, Jennifer; Volpe, Chris; Argenta, Chris; Wille, Mark; Snarski, Stephen; Sherrill, Todd; Lupo, Jasper; Hobson, Ross; Frahm, Jan-Michael; Heinly, Jared

    2012-06-01

    This paper describes the development and demonstration of a soldier-worn augmented reality system testbed that provides intuitive 'heads-up' visualization of tactically-relevant geo-registered icons. Our system combines a robust soldier pose estimation capability with a helmet mounted see-through display to accurately overlay geo-registered iconography (i.e., navigation waypoints, blue forces, aircraft) on the soldier's view of reality. Applied Research Associates (ARA), in partnership with BAE Systems and the University of North Carolina - Chapel Hill (UNC-CH), has developed this testbed system in Phase 2 of the DARPA ULTRA-Vis (Urban Leader Tactical, Response, Awareness, and Visualization) program. The ULTRA-Vis testbed system functions in unprepared outdoor environments and is robust to numerous magnetic disturbances. We achieve accurate and robust pose estimation through fusion of inertial, magnetic, GPS, and computer vision data acquired from helmet kit sensors. Icons are rendered on a high-brightness, 40°×30° field of view see-through display. The system incorporates an information management engine to convert CoT (Cursor-on-Target) external data feeds into mil-standard icons for visualization. The user interface provides intuitive information display to support soldier navigation and situational awareness of mission-critical tactical information.

  3. Ambulatory EHR functionality: a comparison of functionality lists.

    PubMed

    Drury, Barbara M

    2006-01-01

    There is a proliferation of lists intended to define and clarify the functionality of an ambulatory electronic health record system. These lists come from both private and public entities and vary in terminology, granularity, usability, and comprehensiveness. For example, functionality regarding a problem list includes the following possible definitions: * "Create and maintain patient-specific problem lists," from the HL7 Electronic Health Record Draft Standard for Trial Use. * "Provide a flexible mechanism for retrieval of encounter information that can be organized by diagnosis, problem, problem type," from the Bureau of Primary Health Care. * "The system shall associate encounters, orders, medications and notes with one or more problems," from the Certification Commission on Health Information Technology. * "Displays dates of problems on problem list," from COPIC Insurance Co. * "Shall automatically close acute problems using an automated algorithm," from the Physicians Foundations HIT Subcommittee. This article will compare the attributes of these five electronic health record functionality lists and their usefulness to different audiences-clinicians, application developers and payers.

  4. Beyond Helper Phage: Using "Helper Cells" to Select Peptide Affinity Ligands.

    PubMed

    Phipps, M Lisa; Lillo, Antoinetta M; Shou, Yulin; Schmidt, Emily N; Paavola, Chad D; Naranjo, Leslie; Bemdich, Sara; Swanson, Basil I; Bradbury, Andrew R M; Martinez, Jennifer S

    2016-01-01

    Peptides are important affinity ligands for microscopy, biosensing, and targeted delivery. However, because they can have low affinity for their targets, their selection from large naïve libraries can be challenging. When selecting peptidic ligands from display libraries, it is important to: 1) ensure efficient display; 2) maximize the ability to select high affinity ligands; and 3) minimize the effect of the display context on binding. The "helper cell" packaging system has been described as a tool to produce filamentous phage particles based on phagemid constructs with varying display levels, while remaining free of helper phage contamination. Here we report on the first use of this system for peptide display, including the systematic characterization and optimization of helper cells, their inefficient use in antibody display and their use in creating and selecting from a set of phage display peptide libraries. Our libraries were analyzed with unprecedented precision by standard or deep sequencing, and shown to be superior in quality than commercial gold standards. Using our helper cell libraries, we have obtained ligands recognizing Yersinia pestis surface antigen F1V and L-glutamine-binding periplasmic protein QBP. In the latter case, unlike any of the peptide library selections described so far, we used a combination of phage and yeast display to select intriguing peptide ligands. Based on the success of our selections we believe that peptide libraries obtained with helper cells are not only suitable, but preferable to traditional phage display libraries for selection of peptidic ligands.

  5. Colorimetry for CRT displays.

    PubMed

    Golz, Jürgen; MacLeod, Donald I A

    2003-05-01

    We analyze the sources of error in specifying color in CRT displays. These include errors inherent in the use of the color matching functions of the CIE 1931 standard observer when only colorimetric, not radiometric, calibrations are available. We provide transformation coefficients that prove to correct the deficiencies of this observer very well. We consider four different candidate sets of cone sensitivities. Some of these differ substantially; variation among candidate cone sensitivities exceeds the variation among phosphors. Finally, the effects of the recognized forms of observer variation on the visual responses (cone excitations or cone contrasts) generated by CRT stimuli are investigated and quantitatively specified. Cone pigment polymorphism gives rise to variation of a few per cent in relative excitation by the different phosphors--a variation larger than the errors ensuing from the adoption of the CIE standard observer, though smaller than the differences between some candidate cone sensitivities. Macular pigmentation has a larger influence, affecting mainly responses to the blue phosphor. The estimated combined effect of all sources of observer variation is comparable in magnitude with the largest differences between competing cone sensitivity estimates but is not enough to disrupt very seriously the relation between the L and M cone weights and the isoluminance settings of individual observers. It is also comparable with typical instrumental colorimetric errors, but we discuss these only briefly.

  6. Method for Visually Integrating Multiple Data Acquisition Technologies for Real Time and Retrospective Analysis

    NASA Technical Reports Server (NTRS)

    Bogart, Edward H. (Inventor); Pope, Alan T. (Inventor)

    2000-01-01

    A system for display on a single video display terminal of multiple physiological measurements is provided. A subject is monitored by a plurality of instruments which feed data to a computer programmed to receive data, calculate data products such as index of engagement and heart rate, and display the data in a graphical format simultaneously on a single video display terminal. In addition live video representing the view of the subject and the experimental setup may also be integrated into the single data display. The display may be recorded on a standard video tape recorder for retrospective analysis.

  7. ISLE (Image and Signal Processing LISP Environment) reference manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sherwood, R.J.; Searfus, R.M.

    1990-01-01

    ISLE is a rapid prototyping system for performing image and signal processing. It is designed to meet the needs of a person doing development of image and signal processing algorithms in a research environment. The image and signal processing modules in ISLE form a very capable package in themselves. They also provide a rich environment for quickly and easily integrating user-written software modules into the package. ISLE is well suited to applications in which there is a need to develop a processing algorithm in an interactive manner. It is straightforward to develop the algorithms, load it into ISLE, apply themore » algorithm to an image or signal, display the results, then modify the algorithm and repeat the develop-load-apply-display cycle. ISLE consists of a collection of image and signal processing modules integrated into a cohesive package through a standard command interpreter. ISLE developer elected to concentrate their effort on developing image and signal processing software rather than developing a command interpreter. A COMMON LISP interpreter was selected for the command interpreter because it already has the features desired in a command interpreter, it supports dynamic loading of modules for customization purposes, it supports run-time parameter and argument type checking, it is very well documented, and it is a commercially supported product. This manual is intended to be a reference manual for the ISLE functions The functions are grouped into a number of categories and briefly discussed in the Function Summary chapter. The full descriptions of the functions and all their arguments are given in the Function Descriptions chapter. 6 refs.« less

  8. DDML Schema Validation

    DTIC Science & Technology

    2016-02-08

    Data Display Markup Language HUD heads-up display IRIG Inter-Range Instrumentation Group RCC Range Commanders Council SVG Scalable Vector Graphics...T&E test and evaluation TMATS Telemetry Attributes Transfer Standard XML eXtensible Markup Language DDML Schema Validation, RCC 126-16, February...2016 viii This page intentionally left blank. DDML Schema Validation, RCC 126-16, February 2016 1 1. Introduction This Data Display Markup

  9. Functional Proteomics to Identify Moderators of CD8+ T-Cell Function in Melanoma

    DTIC Science & Technology

    2013-09-01

    could then be used to develop imaging agents that are targeted to the TILs. We used an M13 phage vector, which displays a pentavalent peptide as...of the identified transcript. To directly indentify inhibitory molecules, we have proposed to use phage - display expression libraries to perform...of TCD8. 3. To determine the ligands for molecules that can modulate the TCD8 functional state. Body: A. Phage Screen Summary Phage display

  10. Double-heterojunction nanorod light-responsive LEDs for display applications.

    PubMed

    Oh, Nuri; Kim, Bong Hoon; Cho, Seong-Yong; Nam, Sooji; Rogers, Steven P; Jiang, Yiran; Flanagan, Joseph C; Zhai, You; Kim, Jae-Hwan; Lee, Jungyup; Yu, Yongjoon; Cho, Youn Kyoung; Hur, Gyum; Zhang, Jieqian; Trefonas, Peter; Rogers, John A; Shim, Moonsub

    2017-02-10

    Dual-functioning displays, which can simultaneously transmit and receive information and energy through visible light, would enable enhanced user interfaces and device-to-device interactivity. We demonstrate that double heterojunctions designed into colloidal semiconductor nanorods allow both efficient photocurrent generation through a photovoltaic response and electroluminescence within a single device. These dual-functioning, all-solution-processed double-heterojunction nanorod light-responsive light-emitting diodes open feasible routes to a variety of advanced applications, from touchless interactive screens to energy harvesting and scavenging displays and massively parallel display-to-display data communication. Copyright © 2017, American Association for the Advancement of Science.

  11. The effects of display and autopilot functions on pilot workload for Single Pilot Instrument Flight Rule (SPIFR) operations

    NASA Technical Reports Server (NTRS)

    Hoh, Roger H.; Smith, James C.; Hinton, David A.

    1987-01-01

    An analytical and experimental research program was conducted to develop criteria for pilot interaction with advanced controls and displays in single pilot instrument flight rules (SPIFR) operations. The analytic phase reviewed fundamental considerations for pilot workload taking into account existing data, and using that data to develop a divided attention SPIFR pilot workload model. The pilot model was utilized to interpret the two experimental phases. The first experimental phase was a flight test program that evaluated pilot workload in the presence of current and near-term displays and autopilot functions. The second experiment was conducted on a King Air simulator, investigating the effects of co-pilot functions in the presence of very high SPIFR workload. The results indicate that the simplest displays tested were marginal for SPIFR operations. A moving map display aided the most in mental orientation, but had inherent deficiencies as a stand alone replacement for an HSI. Autopilot functions were highly effective for reducing pilot workload. The simulator tests showed that extremely high workload situations can be adequately handled when co-pilot functions are provided.

  12. Split-screen display system and standardized methods for ultrasound image acquisition and multi-frame data processing

    NASA Technical Reports Server (NTRS)

    Selzer, Robert H. (Inventor); Hodis, Howard N. (Inventor)

    2011-01-01

    A standardized acquisition methodology assists operators to accurately replicate high resolution B-mode ultrasound images obtained over several spaced-apart examinations utilizing a split-screen display in which the arterial ultrasound image from an earlier examination is displayed on one side of the screen while a real-time "live" ultrasound image from a current examination is displayed next to the earlier image on the opposite side of the screen. By viewing both images, whether simultaneously or alternately, while manually adjusting the ultrasound transducer, an operator is able to bring into view the real-time image that best matches a selected image from the earlier ultrasound examination. Utilizing this methodology, dynamic material properties of arterial structures, such as IMT and diameter, are measured in a standard region over successive image frames. Each frame of the sequence has its echo edge boundaries automatically determined by using the immediately prior frame's true echo edge coordinates as initial boundary conditions. Computerized echo edge recognition and tracking over multiple successive image frames enhances measurement of arterial diameter and IMT and allows for improved vascular dimension measurements, including vascular stiffness and IMT determinations.

  13. Method and system for providing work machine multi-functional user interface

    DOEpatents

    Hoff, Brian D [Peoria, IL; Akasam, Sivaprasad [Peoria, IL; Baker, Thomas M [Peoria, IL

    2007-07-10

    A method is performed to provide a multi-functional user interface on a work machine for displaying suggested corrective action. The process includes receiving status information associated with the work machine and analyzing the status information to determine an abnormal condition. The process also includes displaying a warning message on the display device indicating the abnormal condition and determining one or more corrective actions to handle the abnormal condition. Further, the process includes determining an appropriate corrective action among the one or more corrective actions and displaying a recommendation message on the display device reflecting the appropriate corrective action. The process may also include displaying a list including the remaining one or more corrective actions on the display device to provide alternative actions to an operator.

  14. Inspiratory capacity at inflation hold in ventilated newborns: a surrogate measure for static compliance of the respiratory system.

    PubMed

    Hentschel, Roland; Semar, Nicole; Guttmann, Josef

    2012-09-01

    To study appropriateness of respiratory system compliance calculation using an inflation hold and compare it with ventilator readouts of pressure and tidal volume as well as with measurement of compliance of the respiratory system with the single-breath-single-occlusion technique gained with a standard lung function measurement. Prospective clinical trial. Level III neonatal unit of a university hospital. Sixty-seven newborns, born prematurely or at term, ventilated for a variety of pathologic conditions. A standardized sigh maneuver with a predefined peak inspiratory pressure of 30 cm H2O, termed inspiratory capacity at inflation hold, was applied. Using tidal volume, exhaled from inspiratory pause down to ambient pressure, as displayed by the ventilator, and predefined peak inspiratory pressure, compliance at inspiratory capacity at inflation hold conditions could be calculated as well as ratio of tidal volume and ventilator pressure using tidal volume and differential pressure at baseline ventilator settings: peak inspiratory pressure minus positive end-expiratory pressure. For the whole cohort, the equation for the regression between tidal volume at inspiratory capacity at inflation hold and compliance of the respiratory system was: compliance of the respiratory system = 0.052 * tidal volume at inspiratory capacity at inflation hold - 0.113, and compliance at inspiratory capacity at inflation hold conditions was closely related to the standard lung function measurement method of compliance of the respiratory system (R = 0.958). In contrast, ratio of tidal volume and ventilator pressure per kilogram calculated from the ventilator readouts and displayed against compliance of the respiratory system per kilogram yielded a broad scatter throughout the whole range of compliance; both were only weakly correlated (R = 0.309) and also the regression line was significantly different from the line of identity (p < .05). Peak inspiratory pressure at study entry did not affect the correlation between compliance at inspiratory capacity at inflation hold conditions and compliance of the respiratory system. After a standard sigh maneuver, inspiratory capacity at inflation hold and the derived quantity compliance at inspiratory capacity at inflation hold conditions can be regarded as a valid, accurate, and reliable surrogate measure for standard compliance of the respiratory system in contrast to ratio of tidal volume and ventilator pressure calculated from the ventilator readouts during ongoing mechanical ventilation at respective ventilator settings.

  15. Consortium for military LCD display procurement

    NASA Astrophysics Data System (ADS)

    Echols, Gregg

    2002-08-01

    International Display Consortium (IDC) is the joining together of display companies to combined their buying power and obtained favorable terms with a major LCD manufacturer. Consolidating the buying power and grouping the demand enables the rugged display industry of avionics, ground vehicles, and ship based display manufacturers to have unencumbered access to high performance AMLCDs while greatly reducing risk and lowering cost. With an unrestricted supply of AMLCD displays, the consortium members have total control of their risk, cost, deliveries and added value partners. Every display manufacturer desires a very close relationship with a display vender. With IDC each consortium member achieves a close relationship. Consortium members enjoy cost effective access to high performance, industry standard sized LCD panels, and modified commercial displays with 100 degree C clearing points and portrait configurations. Consortium members also enjoy proposal support, technical support and long-term support.

  16. 49 CFR 236.329 - Bolt lock.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... TRANSPORTATION RULES, STANDARDS, AND INSTRUCTIONS GOVERNING THE INSTALLATION, INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Interlocking Rules and Instructions... derail and displaying an aspect indicating stop cannot be operated to display a less restrictive aspect...

  17. On Asymptotic Properties of a Number Theoretic Function Arising out of a Spin Chain Modelin Statistical Mechanics

    NASA Astrophysics Data System (ADS)

    Kallies, J.; Özlük, A.; Peter, M.; Snyder, C.

    Let Let N be a positive integer and define Φ(N) as the number of matrices, C, which are products of A and B, where both A and B must occur, such that the trace, Tr(C)=N. It has been conjectured that see [10]. In this note we consider the summatory function and show that

  18. A Harmonious Accounting Duo?

    ERIC Educational Resources Information Center

    Schapperle, Robert F.; Hardiman, Patrick F.

    1992-01-01

    Accountants have urged "harmonization" of standards between the Governmental Accounting Standards Board and the Financial Accounting Standards Board, recommending similar reporting of like transactions. However, varying display of similar accounting events does not necessarily indicate disharmony. The potential for problems because of…

  19. Functional display of family 11 endoxylanases on the surface of phage M13.

    PubMed

    Beliën, T; Hertveldt, K; Van den Brande, K; Robben, J; Van Campenhout, S; Volckaert, G

    2005-02-09

    Two family 11 endoxylanases (EC 3.2.1.8) were functionally displayed on the surface of bacteriophage M13. The genes encoding endo-1,4-xylanase I from Aspergillus niger (ExlA) and endo-1,4-xylanase A from Bacillus subtilis (XynA) were fused to the gene encoding the minor coat protein g3p in phagemid vector pHOS31. Phage rescue resulted in functional monovalent display of the enzymes as was demonstrated by three independent tests. Firstly, purified recombinant phage particles showed a clear hydrolytic activity in an activity assay based on insoluble, chromagenic arabinoxylan substrate. Secondly, specific binding of endoxylanase displaying phages to immobilized endoxylanase inhibitors was demonstrated by interaction ELISA. Finally, two rounds of selection and amplification in a biopanning procedure against immobilized endoxylanase inhibitor were performed. Phages displaying endoxylanases were strongly enriched from background phages displaying unrelated proteins. These results open perspectives to use phage display for analysing protein-protein interactions at the interface between endoxylanases and their inhibitors. In addition, this technology should enable engineering of endoxylanases into novel variants with altered binding properties towards endoxylanase inhibitors.

  20. SAO mission support software and data standards, version 1.0

    NASA Technical Reports Server (NTRS)

    Hsieh, P.

    1993-01-01

    This document defines the software developed by the SAO AXAF Mission Support (MS) Program and defines standards for the software development process and control of data products generated by the software. The SAO MS is tasked to develop and use software to perform a variety of functions in support of the AXAF mission. Software is developed by software engineers and scientists, and commercial off-the-shelf (COTS) software is used either directly or customized through the use of scripts to implement analysis procedures. Software controls real-time laboratory instruments, performs data archiving, displays data, and generates model predictions. Much software is used in the analysis of data to generate data products that are required by the AXAF project, for example, on-orbit mirror performance predictions or detailed characterization of the mirror reflection performance with energy.

  1. The understanding and self-reported use of emotional display rules in children with autism spectrum disorders.

    PubMed

    Begeer, Sander; Banerjee, Robin; Rieffe, Carolien; Terwogt, Mark Meerum; Potharst, Eva; Stegge, Hedy; Koot, Hans M

    2011-08-01

    Two studies examined the understanding and self-reported use of rules for the expressive display of emotions in children with high functioning autism spectrum disorders (HFASD) and in typically developing children. In Study 1, children from the two groups reported display rules equally often when presented with hypothetical situations that provided clear motives for using display rules, although emotion-masking displays were more commonly identified for vignettes with prosocial rather than self-protective motives. In Study 2, children were interviewed about display rule use in real life. Children with HFASD reported display rules less often, included more prototypical examples, and referred less often to prosocial motives than typically developing children. Children with HFASD appear to be aware of display rules, but are less adept at identifying the interpersonal functions of such rules than their typically developing peers.

  2. 36 CFR 1193.43 - Output, display, and control functions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... functions. 1193.43 Section 1193.43 Parks, Forests, and Public Property ARCHITECTURAL AND TRANSPORTATION... and Usability § 1193.43 Output, display, and control functions. All information necessary to operate... amplification, increased signal-to-noise ratio, or combination). For transmitted voice signals, provide a gain...

  3. 36 CFR 1193.43 - Output, display, and control functions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... functions. 1193.43 Section 1193.43 Parks, Forests, and Public Property ARCHITECTURAL AND TRANSPORTATION... and Usability § 1193.43 Output, display, and control functions. All information necessary to operate... amplification, increased signal-to-noise ratio, or combination). For transmitted voice signals, provide a gain...

  4. 36 CFR 1193.43 - Output, display, and control functions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... functions. 1193.43 Section 1193.43 Parks, Forests, and Public Property ARCHITECTURAL AND TRANSPORTATION... and Usability § 1193.43 Output, display, and control functions. All information necessary to operate... amplification, increased signal-to-noise ratio, or combination). For transmitted voice signals, provide a gain...

  5. 36 CFR 1193.43 - Output, display, and control functions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... functions. 1193.43 Section 1193.43 Parks, Forests, and Public Property ARCHITECTURAL AND TRANSPORTATION... and Usability § 1193.43 Output, display, and control functions. All information necessary to operate... amplification, increased signal-to-noise ratio, or combination). For transmitted voice signals, provide a gain...

  6. Ergonomic problems regarding the interactive touch input via screens in onboard and ground-based flight control

    NASA Technical Reports Server (NTRS)

    Holzhausen, K. P.; Gaertner, K. P.

    1985-01-01

    A significant problem concerning the integration of display and switching functions is related to the fact that numerous informative data which have to be processed by man must be read from only a few display devices. A satisfactory ergonomic design of integrated display devices and keyboards is in many cases difficult, because not all functions which can be displayed and selected are simultaneously available. A technical solution which provides an integration of display and functional elements on the basis of the highest flexibility is obtained by using a cathode ray tube with a touch-sensitive screen. The employment of an integrated data input/output system is demonstrated for the cases of onboard and ground-based flight control. Ergonomic studies conducted to investigate the suitability of an employment of touch-sensitive screens are also discussed.

  7. Development and evaluation of a method of calibrating medical displays based on fixed adaptation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sund, Patrik, E-mail: patrik.sund@vgregion.se; Månsson, Lars Gunnar; Båth, Magnus

    2015-04-15

    Purpose: The purpose of this work was to develop and evaluate a new method for calibration of medical displays that includes the effect of fixed adaptation and by using equipment and luminance levels typical for a modern radiology department. Methods: Low contrast sinusoidal test patterns were derived at nine luminance levels from 2 to 600 cd/m{sup 2} and used in a two alternative forced choice observer study, where the adaptation level was fixed at the logarithmic average of 35 cd/m{sup 2}. The contrast sensitivity at each luminance level was derived by establishing a linear relationship between the ten pattern contrastmore » levels used at every luminance level and a detectability index (d′) calculated from the fraction of correct responses. A Gaussian function was fitted to the data and normalized to the adaptation level. The corresponding equation was used in a display calibration method that included the grayscale standard display function (GSDF) but compensated for fixed adaptation. In the evaluation study, the contrast of circular objects with a fixed pixel contrast was displayed using both calibration methods and was rated on a five-grade scale. Results were calculated using a visual grading characteristics method. Error estimations in both observer studies were derived using a bootstrap method. Results: The contrast sensitivities for the darkest and brightest patterns compared to the contrast sensitivity at the adaptation luminance were 37% and 56%, respectively. The obtained Gaussian fit corresponded well with similar studies. The evaluation study showed a higher degree of equally distributed contrast throughout the luminance range with the calibration method compensated for fixed adaptation than for the GSDF. The two lowest scores for the GSDF were obtained for the darkest and brightest patterns. These scores were significantly lower than the lowest score obtained for the compensated GSDF. For the GSDF, the scores for all luminance levels were statistically separated from the average value; three were lower and two were higher. For the compensated GSDF, three of the scores could not be separated from the average value. Conclusions: An observer study using clinically relevant displays and luminance settings has demonstrated that the calibration of displays according to the GSDF causes the perceived contrast to be unevenly distributed when using displays with a high luminance range. As the luminance range increases, the perceived contrast in the dark and bright regions will be significantly lower than the perceived contrast in the middle of the luminance range. A new calibration method that includes the effect of fixed adaptation was developed and evaluated in an observer study and was found to distribute the contrast of the display more evenly throughout the grayscale than the GSDF.« less

  8. Real Time Urban Acoustics Using Commerical Technologies

    DTIC Science & Technology

    2011-08-01

    delays, and rendering for binaural or surround sound display [2]. VibeStudio does not include propagation effects of reflections, diffusion, or...available for rending both binaural headphones displays as well as standard and arbitrary surround sound formats. For this reason, minimal detail is...provided in this paper and the reader is referred to [2]. An image illustrating a binaural display scenario and a typical surround sound setup are

  9. Recent advances and product enhancements in reflective cholesteric displays

    NASA Astrophysics Data System (ADS)

    Khan, Asad; Schneider, Tod; Miller, Nick; Marhefka, Duane; Ernst, Todd; Nicholson, Forrest; Doane, Joseph W.

    2005-04-01

    Bistable reflective cholesteric displays are a liquid crystal display technology developed to fill a market need for very low power displays on a low-cost, high resolution passive matrix. Their unique look, high reflectivity, bistability, and simple structure make them an ideal flat panel display choice for handheld or other portable devices where small lightweight batteries with long lifetimes are important. We discuss recent advances in cholesteric display technology at Kent Displays such as progress towards single layer black and white displays, standard products, lower cost display modules, and various interface options for cholesteric display applications. It will be shown that inclusion of radio frequency (rf) control options and serial peripheral interface (spi) can greatly enhance the cholesteric display module market penetration by enabling quick integration into end devices. Finally, some discussion will be on the progress of the development of flexible reflective cholesteric displays. These flexible displays can dramatically change industrial design methods by enabling curved surfaces with displays integrated in them. Additional discussion in the paper will include applications of various display modes including signs, hand held instrumentation, and the electronic book and reader.

  10. Multi-Function Displays: A Guide for Human Factors Evaluation

    DTIC Science & Technology

    2013-11-01

    mental workload in rotary wing aircraft . Ergonomics , 36, 1121 - 40. Smith, S., & Mosier, J. (1984). Design guidelines for the user interface for...Monterey Technologies, Inc., except one designated by (*), who is from CAMI. 16. Abstract This guide is designed to assist aircraft ...section. 17. Key Words 18. Distribution Statement Multi-Function Displays, Display Design , Avionics, Human Factors Criteria, Aircraft

  11. The Real Time Display Builder (RTDB)

    NASA Technical Reports Server (NTRS)

    Kindred, Erick D.; Bailey, Samuel A., Jr.

    1989-01-01

    The Real Time Display Builder (RTDB) is a prototype interactive graphics tool that builds logic-driven displays. These displays reflect current system status, implement fault detection algorithms in real time, and incorporate the operational knowledge of experienced flight controllers. RTDB utilizes an object-oriented approach that integrates the display symbols with the underlying operational logic. This approach allows the user to specify the screen layout and the driving logic as the display is being built. RTDB is being developed under UNIX in C utilizing the MASSCOMP graphics environment with appropriate functional separation to ease portability to other graphics environments. RTDB grew from the need to develop customized real-time data-driven Space Shuttle systems displays. One display, using initial functionality of the tool, was operational during the orbit phase of STS-26 Discovery. RTDB is being used to produce subsequent displays for the Real Time Data System project currently under development within the Mission Operations Directorate at NASA/JSC. The features of the tool, its current state of development, and its applications are discussed.

  12. Identifying Bacterial Immune Evasion Proteins Using Phage Display.

    PubMed

    Fevre, Cindy; Scheepmaker, Lisette; Haas, Pieter-Jan

    2017-01-01

    Methods aimed at identification of immune evasion proteins are mainly rely on in silico prediction of sequence, structural homology to known evasion proteins or use a proteomics driven approach. Although proven successful these methods are limited by a low efficiency and or lack of functional identification. Here we describe a high-throughput genomic strategy to functionally identify bacterial immune evasion proteins using phage display technology. Genomic bacterial DNA is randomly fragmented and ligated into a phage display vector that is used to create a phage display library expressing bacterial secreted and membrane bound proteins. This library is used to select displayed bacterial secretome proteins that interact with host immune components.

  13. Beyond helper phage: Using "helper cells" to select peptide affinity ligands

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Phipps, Mary Lisa; Lillo, Antoinetta M.; Shou, Yulin

    Peptides are important affinity ligands for microscopy, biosensing, and targeted delivery. However, because they can have low affinity for their targets, their selection from large naïve libraries can be challenging. When selecting peptidic ligands from display libraries, it is important to: 1) ensure efficient display; 2) maximize the ability to select high affinity ligands; and 3) minimize the effect of the display context on binding. The “helper cell” packaging system has been described as a tool to produce filamentous phage particles based on phagemid constructs with varying display levels, while remaining free of helper phage contamination. Here we report onmore » the first use of this system for peptide display, including the systematic characterization and optimization of helper cells, their inefficient use in antibody display and their use in creating and selecting from a set of phage display peptide libraries. Our libraries were analyzed with unprecedented precision by standard or deep sequencing, and shown to be superior in quality than commercial gold standards. Using our helper cell libraries, we have obtained ligands recognizing Yersinia pestis surface antigen F1V and L-glutamine-binding periplasmic protein QBP. In the latter case, unlike any of the peptide library selections described so far, we used a combination of phage and yeast display to select intriguing peptide ligands. Here, based on the success of our selections we believe that peptide libraries obtained with helper cells are not only suitable, but preferable to traditional phage display libraries for selection of peptidic ligands.« less

  14. Beyond helper phage: Using "helper cells" to select peptide affinity ligands

    DOE PAGES

    Phipps, Mary Lisa; Lillo, Antoinetta M.; Shou, Yulin; ...

    2016-09-14

    Peptides are important affinity ligands for microscopy, biosensing, and targeted delivery. However, because they can have low affinity for their targets, their selection from large naïve libraries can be challenging. When selecting peptidic ligands from display libraries, it is important to: 1) ensure efficient display; 2) maximize the ability to select high affinity ligands; and 3) minimize the effect of the display context on binding. The “helper cell” packaging system has been described as a tool to produce filamentous phage particles based on phagemid constructs with varying display levels, while remaining free of helper phage contamination. Here we report onmore » the first use of this system for peptide display, including the systematic characterization and optimization of helper cells, their inefficient use in antibody display and their use in creating and selecting from a set of phage display peptide libraries. Our libraries were analyzed with unprecedented precision by standard or deep sequencing, and shown to be superior in quality than commercial gold standards. Using our helper cell libraries, we have obtained ligands recognizing Yersinia pestis surface antigen F1V and L-glutamine-binding periplasmic protein QBP. In the latter case, unlike any of the peptide library selections described so far, we used a combination of phage and yeast display to select intriguing peptide ligands. Here, based on the success of our selections we believe that peptide libraries obtained with helper cells are not only suitable, but preferable to traditional phage display libraries for selection of peptidic ligands.« less

  15. A cost-effective and simple electronic solution to communication with patients with tracheostomy in a burns and intensive care setting.

    PubMed

    Javed, Muhammad; Dingley, John; Dickson, William; Shokrollahi, Kayvan

    2014-02-01

    Ventilated patients in ITU (intensive treatment unit) tend to be challenging to communicate with, especially patients who are being weaned. These patients usually have tracheostomy in situ and use means such as writing or letter boards to communicate. The situation becomes complex in patient groups that have burn injuries with bulky dressings and restricted upper limb function. We demonstrate a low cost, easy to use, potentially disposable system that can display words on any television screen via patient input device for such patient groups. The system consists of input device incorporated with Arduino microcontroller (an open-source electronics prototyping platform based on easy-to-use hardware and software intended for creating interactive environments) and 4 generously oversized control buttons. These are used to control the cursor movements (up, down, left, right) while a fifth has a "select" function. These are large enough to be pressed by an entire bandaged hand using gross upper limb movements only. A standard television is used to display menu containing the 26 letters of the alphabet and a flashing cursor. The patient selects the required letters/icon by moving the cursor and the words so created are displayed along the lower part of the screen for the carers to read. It is envisaged that anyone with basic craft skills should be able to construct this device. This device is a self-contained, cost-effective, simple, and open-source system that can be used effectively to bridge the communication gap with significant potential for patient care globally.

  16. System analysis of graphics processor architecture using virtual prototyping

    NASA Astrophysics Data System (ADS)

    Hancock, William R.; Groat, Jeff; Steeves, Todd; Spaanenburg, Henk; Shackleton, John

    1995-06-01

    Honeywell has been actively involved in the definition of the next generation display processors for military and commercial cockpits. A major concern is how to achieve super graphics workstation performance in avionics application. Most notable are requirements for low volume, low power, harsh environmental conditions, real-time performance and low cost. This paper describes the application of VHDL to the system analysis tasks associated with achieving these goals in a cost effective manner. The paper will describe the top level architecture identified to provide the graphical and video processing power needed to drive future high resolution display devices and to generate more natural panoramic 3D formats. The major discussion, however, will be on the use of VHDL to model the processing elements and customized pipelines needed to realize the architecture and for doing the complex system tradeoff studies necessary to achieve a cost effective implementation. New software tools have been developed to allow 'virtual' prototyping in the VHDL environment. This results in a hardware/software codesign using VHDL performance and functional models. This unique architectural tool allows simulation and tradeoffs within a standard and tightly integrated toolset, which eventually will be used to specify and design the entire system from the top level requirements and system performance to the lowest level individual ASICs. New processing elements, algorithms, and standard graphical inputs can be designed, tested and evaluated without the costly hardware prototyping using the innovative 'virtual' prototyping techniques which are evolving on this project. In addition, virtual prototyping of the display processor does not bind the preliminary design to point solutions as a physical prototype will. when the development schedule is known, one can extrapolate processing elements performance and design the system around the most current technology.

  17. 2D Potential Theory using Complex Algebra: New Perspectives for Interpretation of Marine Magnetic Anomaly

    NASA Astrophysics Data System (ADS)

    Le Maire, P.; Munschy, M.

    2017-12-01

    Interpretation of marine magnetic anomalies enable to perform accurate global kinematic models. Several methods have been proposed to compute the paleo-latitude of the oceanic crust as its formation. A model of the Earth's magnetic field is used to determine a relationship between the apparent inclination of the magnetization and the paleo-latitude. Usually, the estimation of the apparent inclination is qualitative, with the fit between magnetic data and forward models. We propose to apply a new method using complex algebra to obtain the apparent inclination of the magnetization of the oceanic crust. For two dimensional bodies, we rewrite Talwani's equations using complex algebra; the corresponding complex function of the complex variable, called CMA (complex magnetic anomaly) is easier to use for forward modelling and inversion of the magnetic data. This complex equation allows to visualize the data in the complex plane (Argand diagram) and offers a new way to interpret data (curves to the right of the figure (B), while the curves to the left represent the standard display of magnetic anomalies (A) for the model displayed (C) at the bottom of the figure). In the complex plane, the effect of the apparent inclination is to rotate the curves, while on the standard display the evolution of the shape of the anomaly is more complicated (figure). This innovative method gives the opportunity to study a set of magnetic profiles (provided by the Geological Survey of Norway) acquired in the Norwegian Sea, near the Jan Mayen fracture zone. In this area, the age of the oceanic crust ranges from 40 to 55 Ma and the apparent inclination of the magnetization is computed.

  18. Real-time MRI guidance of cardiac interventions.

    PubMed

    Campbell-Washburn, Adrienne E; Tavallaei, Mohammad A; Pop, Mihaela; Grant, Elena K; Chubb, Henry; Rhode, Kawal; Wright, Graham A

    2017-10-01

    Cardiac magnetic resonance imaging (MRI) is appealing to guide complex cardiac procedures because it is ionizing radiation-free and offers flexible soft-tissue contrast. Interventional cardiac MR promises to improve existing procedures and enable new ones for complex arrhythmias, as well as congenital and structural heart disease. Guiding invasive procedures demands faster image acquisition, reconstruction and analysis, as well as intuitive intraprocedural display of imaging data. Standard cardiac MR techniques such as 3D anatomical imaging, cardiac function and flow, parameter mapping, and late-gadolinium enhancement can be used to gather valuable clinical data at various procedural stages. Rapid intraprocedural image analysis can extract and highlight critical information about interventional targets and outcomes. In some cases, real-time interactive imaging is used to provide a continuous stream of images displayed to interventionalists for dynamic device navigation. Alternatively, devices are navigated relative to a roadmap of major cardiac structures generated through fast segmentation and registration. Interventional devices can be visualized and tracked throughout a procedure with specialized imaging methods. In a clinical setting, advanced imaging must be integrated with other clinical tools and patient data. In order to perform these complex procedures, interventional cardiac MR relies on customized equipment, such as interactive imaging environments, in-room image display, audio communication, hemodynamic monitoring and recording systems, and electroanatomical mapping and ablation systems. Operating in this sophisticated environment requires coordination and planning. This review provides an overview of the imaging technology used in MRI-guided cardiac interventions. Specifically, this review outlines clinical targets, standard image acquisition and analysis tools, and the integration of these tools into clinical workflow. 1 Technical Efficacy: Stage 5 J. Magn. Reson. Imaging 2017;46:935-950. © 2017 International Society for Magnetic Resonance in Medicine.

  19. 23 CFR 1.2 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    .... Advertising standards. The “National Standards for Regulation by States of Outdoor Advertising Signs, Displays... of Federal aid for highways. Secondary road plan. A plan for administration of Federal aid for...

  20. 23 CFR 1.2 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    .... Advertising standards. The “National Standards for Regulation by States of Outdoor Advertising Signs, Displays... of Federal aid for highways. Secondary road plan. A plan for administration of Federal aid for...

  1. 23 CFR 1.2 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    .... Advertising standards. The “National Standards for Regulation by States of Outdoor Advertising Signs, Displays... of Federal aid for highways. Secondary road plan. A plan for administration of Federal aid for...

  2. M&S Smart System Contrast Sensitivity Measurements Compared With Standard Visual Function Measurements in Primary Open-Angle Glaucoma Patients.

    PubMed

    Liu, Jessica L; McAnany, J Jason; Wilensky, Jacob T; Aref, Ahmad A; Vajaranant, Thasarat S

    2017-06-01

    To evaluate the nature and extent of letter contrast sensitivity (CS) deficits in glaucoma patients using a commercially available computer-based system (M&S Smart System II) and to compare the letter CS measurements to standard clinical measures of visual function. Ninety-four subjects with primary open-angle glaucoma participated. Each subject underwent visual acuity, letter CS, and standard automated perimetry testing (Humphrey SITA 24-2). All subjects had a best-corrected visual acuity (BCVA) of 0.3 log MAR (20/40 Snellen equivalent) or better and reliable standard automated perimetry (fixation losses, false positives, and false negatives <33%). CS functions were estimated from the letter CS and BCVA measurements. The area under the CS function (AUCSF), which is a combined index of CS and BCVA, was derived and analyzed. The mean (± SD) BCVA was 0.08±0.10 log MAR (∼20/25 Snellen equivalent), the mean CS was 1.38±0.17, and the mean Humphrey Visual Field mean deviation (HVF MD) was -7.22±8.10 dB. Letter CS and HVF MD correlated significantly (r=0.51, P<0.001). BCVA correlated significantly with letter CS (r=-0.22, P=0.03), but not with HVF MD (r=-0.12, P=0.26). A subset of the subject sample (∼20%) had moderate to no field loss (≤-6 dB MD) and minimal to no BCVA loss (≤0.3 log MAR), but had poor letter CS. AUCSF was correlated significantly with HVF MD (r=0.46, P<0.001). The present study is the first to evaluate letter CS in glaucoma using the digital M&S Smart System II display. Letter CS correlated significantly with standard HVF MD measurements, suggesting that letter CS may provide a useful adjunct test of visual function for glaucoma patients. In addition, the significant correlation between HVF MD and the combined index of CS and BCVA (AUCSF) suggests that this measure may also be useful for quantifying visual dysfunction in glaucoma patients.

  3. Augmented Reality Tool for the Situational Awareness Improvement of UAV Operators

    PubMed Central

    Ruano, Susana; Cuevas, Carlos; Gallego, Guillermo; García, Narciso

    2017-01-01

    Unmanned Aerial Vehicles (UAVs) are being extensively used nowadays. Therefore, pilots of traditional aerial platforms should adapt their skills to operate them from a Ground Control Station (GCS). Common GCSs provide information in separate screens: one presents the video stream while the other displays information about the mission plan and information coming from other sensors. To avoid the burden of fusing information displayed in the two screens, an Augmented Reality (AR) tool is proposed in this paper. The AR system has two functionalities for Medium-Altitude Long-Endurance (MALE) UAVs: route orientation and target identification. Route orientation allows the operator to identify the upcoming waypoints and the path that the UAV is going to follow. Target identification allows a fast target localization, even in the presence of occlusions. The AR tool is implemented following the North Atlantic Treaty Organization (NATO) standards so that it can be used in different GCSs. The experiments show how the AR tool improves significantly the situational awareness of the UAV operators. PMID:28178189

  4. Augmented Reality Tool for the Situational Awareness Improvement of UAV Operators.

    PubMed

    Ruano, Susana; Cuevas, Carlos; Gallego, Guillermo; García, Narciso

    2017-02-06

    Unmanned Aerial Vehicles (UAVs) are being extensively used nowadays. Therefore, pilots of traditional aerial platforms should adapt their skills to operate them from a Ground Control Station (GCS). Common GCSs provide information in separate screens: one presents the video stream while the other displays information about the mission plan and information coming from other sensors. To avoid the burden of fusing information displayed in the two screens, an Augmented Reality (AR) tool is proposed in this paper. The AR system has two functionalities for Medium-Altitude Long-Endurance (MALE) UAVs: route orientation and target identification. Route orientation allows the operator to identify the upcoming waypoints and the path that the UAV is going to follow. Target identification allows a fast target localization, even in the presence of occlusions. The AR tool is implemented following the North Atlantic Treaty Organization (NATO) standards so that it can be used in different GCSs. The experiments show how the AR tool improves significantly the situational awareness of the UAV operators.

  5. 36 CFR § 1193.43 - Output, display, and control functions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... functions. § 1193.43 Section § 1193.43 Parks, Forests, and Public Property ARCHITECTURAL AND... Accessibility and Usability § 1193.43 Output, display, and control functions. All information necessary to... amplification, increased signal-to-noise ratio, or combination). For transmitted voice signals, provide a gain...

  6. Engineering M13 for phage display.

    PubMed

    Sidhu, S S

    2001-09-01

    Phage display is achieved by fusing polypeptide libraries to phage coat proteins. The resulting phage particles display the polypeptides on their surfaces and they also contain the encoding DNA. Library members with particular functions can be isolated with simple selections and polypeptide sequences can be decoded from the encapsulated DNA. The technology's success depends on the efficiency with which polypeptides can be displayed on the phage surface, and significant progress has been made in engineering M13 bacteriophage coat proteins as improved phage display platforms. Functional display has been achieved with all five M13 coat proteins, with both N- and C-terminal fusions. Also, coat protein mutants have been designed and selected to improve the efficiency of heterologous protein display, and in the extreme case, completely artificial coat proteins have been evolved specifically as display platforms. These studies demonstrate that the M13 phage coat is extremely malleable, and this property can be used to engineer the phage particle specifically for phage display. These improvements expand the utility of phage display as a powerful tool in modern biotechnology.

  7. Video Display Terminals: Radiation Issues.

    ERIC Educational Resources Information Center

    Murray, William E.

    1985-01-01

    Discusses information gathered in past few years related to health effects of video display terminals (VDTs) with particular emphasis given to issues raised by VDT users. Topics covered include radiation emissions, health concerns, radiation surveys, occupational radiation exposure standards, and long-term risks. (17 references) (EJS)

  8. IceT users' guide and reference.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moreland, Kenneth D.

    2011-01-01

    The Image Composition Engine for Tiles (IceT) is a high-performance sort-last parallel rendering library. In addition to providing accelerated rendering for a standard display, IceT provides the unique ability to generate images for tiled displays. The overall resolution of the display may be several times larger than any viewport that may be rendered by a single machine. This document is an overview of the user interface to IceT.

  9. Virtual reality technology prevents accidents in extreme situations

    NASA Astrophysics Data System (ADS)

    Badihi, Y.; Reiff, M. N.; Beychok, S.

    2012-03-01

    This research is aimed at examining the added value of using Virtual Reality (VR) in a driving simulator to prevent road accidents, specifically by improving drivers' skills when confronted with extreme situations. In an experiment, subjects completed a driving scenario using two platforms: A 3-D Virtual Reality display system using an HMD (Head-Mounted Display), and a standard computerized display system based on a standard computer monitor. The results show that the average rate of errors (deviating from the driving path) in a VR environment is significantly lower than in the standard one. In addition, there was no compensation between speed and accuracy in completing the driving mission. On the contrary: The average speed was even slightly faster in the VR simulation than in the standard environment. Thus, generally, despite the lower rate of deviation in VR setting, it is not achieved by driving slower. When the subjects were asked about their personal experiences from the training session, most of the subjects responded that among other things, the VR session caused them to feel a higher sense of commitment to the task and their performance. Some of them even stated that the VR session gave them a real sensation of driving.

  10. Method and system for monitoring and displaying engine performance parameters

    NASA Technical Reports Server (NTRS)

    Abbott, Terence S. (Inventor); Person, Lee H., Jr. (Inventor)

    1988-01-01

    The invention is believed a major improvement that will have a broad application in governmental and commercial aviation. It provides a dynamic method and system for monitoring and simultaneously displaying in easily scanned form the available, predicted, and actual thrust of a jet aircraft engine under actual operating conditions. The available and predicted thrusts are based on the performance of a functional model of the aircraft engine under the same operating conditions. Other critical performance parameters of the aircraft engine and functional model are generated and compared, the differences in value being simultaneously displayed in conjunction with the displayed thrust values. Thus, the displayed information permits the pilot to make power adjustments directly while keeping him aware of total performance at a glance of a single display panel.

  11. Scream-embrace displays in wild black-horned capuchin monkeys.

    PubMed

    Lynch Alfaro, Jessica

    2008-06-01

    Reintroduction of capuchin monkeys (Cebus apella) into their social group in captivity can elicit sirena screams and embraces. Captive scream-embrace displays are male biased, and females never perform sirena screams. One hypothesis is that scream-embrace displays serve a tension-reduction or reconciliatory function between males with conflicting interests. Alternatively, these displays may function to maintain strong affiliative bonds between friendly male dyads. Scream and/or embrace displays in wild Brazilian black-horned capuchins were analyzed for social and ecological contexts, behavioral components, and individuals involved. Seventy-two displays were observed during the 199-day study period. Among the 66 displays for which both members could be identified by sex, there were 42 occurrences of male-male dyads, 17 of male-female dyads, and seven of female-female dyads. Scream-embrace dyads were male-male pairs significantly more often than expected from group membership, and the alpha male was the only male to engage in scream-embrace displays with females. Female-female pairs did embrace, but never emitted sirena screams. Displays most commonly occurred in "reunion" contexts, primarily the reuniting of subgroups after hours or days out of contact, but also after intergroup encounters, and across groups in "intergroup" displays. Displays were rare, but socially contagious, and subgroup reunions could elicit multiple displays in rapid succession. Although the occurrence of screams and embraces was positively correlated, both behaviors also occurred independently, and their functions may be different. Male sirena screams may be honest advertisements of united alliances, directed toward a third party, whereas the embrace may be a risky affiliative signal, directed primarily within the dyad. Copyright 2008 Wiley-Liss, Inc.

  12. A Visual Model for the Variance and Standard Deviation

    ERIC Educational Resources Information Center

    Orris, J. B.

    2011-01-01

    This paper shows how the variance and standard deviation can be represented graphically by looking at each squared deviation as a graphical object--in particular, as a square. A series of displays show how the standard deviation is the size of the average square.

  13. Verbal Modification via Visual Display

    ERIC Educational Resources Information Center

    Richmond, Edmun B.; Wallace-Childers, La Donna

    1977-01-01

    The inability of foreign language students to produce acceptable approximations of new vowel sounds initiated a study to devise a real-time visual display system whereby the students could match vowel production to a visual pedagogical model. The system used amateur radio equipment and a standard oscilloscope. (CHK)

  14. 49 CFR 236.756 - Lock, bolt.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... TRANSPORTATION RULES, STANDARDS, AND INSTRUCTIONS GOVERNING THE INSTALLATION, INSPECTION, MAINTENANCE, AND REPAIR... a train movement, the signal governing that movement cannot display an aspect to proceed; and that will prevent a movement of the switch, derail or movable-point frog unless the signal displays its most...

  15. A Real-Time Phase Vector Display for EEG Monitoring

    NASA Technical Reports Server (NTRS)

    Finger, Herbert J.; Anliker, James E.; Rimmer, Tamara

    1973-01-01

    A real-time, computer-based, phase vector display system has been developed which will output a vector whose phase is equal to the delay between a trigger and the peak of a function which is quasi-coherent with respect to the trigger. The system also contains a sliding averager which enables the operator to average successive trials before calculating the phase vector. Data collection, averaging and display generation are performed on a LINC-8 computer. Output displays appear on several X-Y CRT display units and on a kymograph camera/oscilloscope unit which is used to generate photographs of time-varying phase vectors or contourograms of time-varying averages of input functions.

  16. Multi-function displays : a guide for human factors evaluation.

    DOT National Transportation Integrated Search

    2013-11-01

    This guide is designed to assist aircraft certification personnel and avionics : manufacturers in evaluating the human factors aspects of Multi-function Displays : (MFDs) for FAA certification. The guide focuses specifically on human factors and : do...

  17. Phonomicrosurgery in singers and performing artists: treatment outcomes, management theories, and future directions.

    PubMed

    Zeitels, Steven M; Hillman, Robert E; Desloge, Rosemary; Mauri, Marcello; Doyle, Patricia B

    2002-12-01

    Phonomicrosurgery in performing artists has historically been approached with great trepidation, and vocal outcome data are sparse. The vocal liability of surgically disturbing the superficial lamina propria (SLP) and epithelium must be balanced with the inherent detrimental vocal effect of the lesion(s). A prospective investigation was performed on 185 performing artists who underwent phonomicrosurgical resection of 365 lesions: 201 nodules, 71 polyps, 66 varices and ectasias, 13 cysts, 8 keratotic lesions, 2 granulomas, 2 Reinke's edema, and 2 papillomas. Nearly all patients with SLP lesions reported improvement in their postsurgical vocal function. This subjective result was supported by objective acoustic and aerodynamic measures. All postsurgical objective vocal function measures fell within normal limits, including a few that displayed presurgical abnormalities. However, given the relative insensitivity of standard objective measures to assess higher-level vocal performance-related factors, it is even more noteworthy that 8 of 24 objective measures displayed statistically significant postsurgical improvements in vocal function. Such changes in objective measures mostly reflect overall enhancement in the efficiency of voice production. Phonomicrosurgical resection of vocal fold lesions in performing artists is enjoying an expanding role because of a variety of improvements in diagnostic assessment, surgical instrumentation and techniques, and specialized rehabilitation. Most of these lesions are the result of phonotrauma and arise within the SLP. Successful management depends on prudent patient selection and counseling, ultraprecise technique, and vigorqus vocal rehabilitation. Furthermore, an understanding of the vocal function and dysfunction of this high-performance population provides all otolaryngologists who manage laryngeal problems with valuable information that they can extrapolate for use in their practices.

  18. Evidence for the Detection of Subclinical Retinal Involvement in Systemic Lupus Erythematosus and Sjögren Syndrome: A Potential Association with Therapies.

    PubMed

    Conigliaro, Paola; Triggianese, Paola; Draghessi, Gianluca; Canofari, Claudia; Aloe, Gianluca; Chimenti, Maria Sole; Valeri, Claudia; Nucci, Carlo; Perricone, Roberto; Cesareo, Massimo

    2018-06-14

    Retinal involvement in systemic lupus erythematosus (SLE) and Sjögren syndrome (SS) may be subclinical and thus underdiagnosed. We aimed at evaluating morphological and functional visual abnormalities in a cohort of SLE and SS patients in the absence of an overt clinical visual impairment. We also investigated potential associations between retinal disorders and disease activity, organ involvement, and treatment with steroid and/or hydroxychloroquine. The study comprised 42 SLE and 36 primary SS patients and 76 healthy controls (HC). Ophthalmological examination, standard automated perimetry, spectral-domain optical coherence tomography, and fundus perimetry were performed. Retinal thickness of the posterior pole was not different between SLE and HC groups, but it was reduced in the SS group compared with both the HC and the SLE group. In SLE and SS patients, mean defect and pattern standard deviation by standard automated perimetry were higher than in HC. Visual field index values were lower in both SLE and SS patients than in HC. SLE patients with nephritis displayed increased mean defect and pattern standard deviation and reduced visual field index values compared to patients without nephritis. In SLE and SS patients, fundus perimetry differential sensitivity was reduced, and mean defect values were higher than in HC. Disturbances in fundus perimetry in the SLE group were more prevalent in steroid-naïve patients and in SS patients who received a cumulative hydroxychloroquine dose > 1,000 g. Functional eye impairment was demonstrated in SLE patients, possibly associated with kidney involvement. In SLE, corticosteroids might exert a protective role. Morphological alterations and functional impairment were detected in SS patients, which may be linked to hydroxychloroquine toxicity. © 2018 S. Karger AG, Basel.

  19. Characterizing Accuracy and Precision of Glucose Sensors and Meters

    PubMed Central

    2014-01-01

    There is need for a method to describe precision and accuracy of glucose measurement as a smooth continuous function of glucose level rather than as a step function for a few discrete ranges of glucose. We propose and illustrate a method to generate a “Glucose Precision Profile” showing absolute relative deviation (ARD) and /or %CV versus glucose level to better characterize measurement errors at any glucose level. We examine the relationship between glucose measured by test and comparator methods using linear regression. We examine bias by plotting deviation = (test – comparator method) versus glucose level. We compute the deviation, absolute deviation (AD), ARD, and standard deviation (SD) for each data pair. We utilize curve smoothing procedures to minimize the effects of random sampling variability to facilitate identification and display of the underlying relationships between ARD or %CV and glucose level. AD, ARD, SD, and %CV display smooth continuous relationships versus glucose level. Estimates of MARD and %CV are subject to relatively large errors in the hypoglycemic range due in part to a markedly nonlinear relationship with glucose level and in part to the limited number of observations in the hypoglycemic range. The curvilinear relationships of ARD and %CV versus glucose level are helpful when characterizing and comparing the precision and accuracy of glucose sensors and meters. PMID:25037194

  20. Conceptual Design Standards for eXternal Visibility System (XVS) Sensor and Display Resolution

    NASA Technical Reports Server (NTRS)

    Bailey, Randall E.; Wilz, Susan J.; Arthur, Jarvis J, III

    2012-01-01

    NASA is investigating eXternal Visibility Systems (XVS) concepts which are a combination of sensor and display technologies designed to achieve an equivalent level of safety and performance to that provided by forward-facing windows in today s subsonic aircraft. This report provides the background for conceptual XVS design standards for display and sensor resolution. XVS resolution requirements were derived from the basis of equivalent performance. Three measures were investigated: a) human vision performance; b) see-and-avoid performance and safety; and c) see-to-follow performance. From these three factors, a minimum but perhaps not sufficient resolution requirement of 60 pixels per degree was shown for human vision equivalence. However, see-and-avoid and see-to-follow performance requirements are nearly double. This report also reviewed historical XVS testing.

  1. Psychophysical Comparison Of A Video Display System To Film By Using Bone Fracture Images

    NASA Astrophysics Data System (ADS)

    Seeley, George W.; Stempski, Mark; Roehrig, Hans; Nudelman, Sol; Capp, M. P.

    1982-11-01

    This study investigated the possibility of using a video display system instead of film for radiological diagnosis. Also investigated were the relationships between characteristics of the system and the observer's accuracy level. Radiologists were used as observers. Thirty-six clinical bone fractures were separated into two matched sets of equal difficulty. The difficulty parameters and ratings were defined by a panel of expert bone radiologists at the Arizona Health Sciences Center, Radiology Department. These two sets of fracture images were then matched with verifiably normal images using parameters such as film type, angle of view, size, portion of anatomy, the film's density range, and the patient's age and sex. The two sets of images were then displayed, using a counterbalanced design, to each of the participating radiologists for diagnosis. Whenever a response was given to a video image, the radiologist used enhancement controls to "window in" on the grey levels of interest. During the TV phase, the radiologist was required to record the settings of the calibrated controls of the image enhancer during interpretation. At no time did any single radiologist see the same film in both modes. The study was designed so that a standard analysis of variance would show the effects of viewing mode (film vs TV), the effects due to stimulus set, and any interactions with observers. A signal detection analysis of observer performance was also performed. Results indicate that the TV display system is almost as good as the view box display; an average of only two more errors were made on the TV display. The difference between the systems has been traced to four observers who had poor accuracy on a small number of films viewed on the TV display. This information is now being correlated with the video system's signal-to-noise ratio (SNR), signal transfer function (STF), and resolution measurements, to obtain information on the basic display and enhancement requirements for a video-based radiologic system. Due to time constraints the results are not included here. The complete results of this study will be reported at the conference.

  2. Disruptions in follicle cell functions in the ovaries of rhesus monkeys during summer

    PubMed Central

    VandeVoort, Catherine A.; Mtango, Namdori R.; Midic, Uros

    2015-01-01

    Oocytes isolated from female rhesus monkeys following standard ovarian stimulation protocols during the summer months displayed a reduced capacity to mature compared with stimulation during the normal breeding season. Because the gene expression profiles of oocyte-associated cumulus cells and mural granulosa cells (CCs and GCs) are indicative of altered oocyte quality and can provide insight into intrafollicular processes that may be disrupted during oogenesis, we performed array-based transcriptome comparisons of CCs and GCs from summer and normal breeding season stimulation cycles. Summer CCs and GCs both display deficiencies in expression of mRNAs related to cell proliferation, angiogenesis, and endocrine signaling, as well as reduced expression of glycogen phosphorylase. Additionally, CCs display deficiencies in expression of mRNAs related to stress response. These results provide the first insight into the specific molecular pathways and processes that are disrupted in the follicles of rhesus macaque females during the summer season. Some of the changes seen in summer GCs and CCs have been reported in humans and in other model mammalian species. This suggests that the seasonal effects seen in the rhesus monkey may help us to understand better the mechanisms that contribute to reduced oocyte quality and fertility in humans. PMID:25586978

  3. The correlation between effective renal plasma flow (ERPF) and glomerular filtration rate (GFR) with renal scintigraphy 99mTc-DTPA study

    NASA Astrophysics Data System (ADS)

    Ratnasari, D.; Nazir, F.; Toresano, L. O. H. Z.; Pawiro, S. A.; Soejoko, D. S.

    2016-03-01

    The prevalence of chronic renal diseases in Indonesia has an increasing annual trend, because it is frequently unrecognized and often co-exists with other disease. GFR and ERPF are parameters currently utilized to estimate renal function at routine renal scintigraphy 99m-Tc DTPA study. This study used 99m-Tc DTPA to measure GFR and ERPF. The purpose of this study was to find the correlation between ERPF and GFR, for ERPF analysis with Schlegel's method, and GFR analysis with Gate's method, as well as to find correction factor between both variables. Analysis of renal scintigraphy has been performed at Department of Nuclear Medicine Pertamina Center Hospital to thirty patient images acquired from 2014 to 2015 which were analyzed retrospectively data, using gamma camera dual head with counting method from renal scintigraphy 99m-Tc DTPA study. The calculation was executed by means of both display and manual calculation. Pearson's statistical analysis resulted on Positive Correlation for all data, with ERPF and GFR (display) showing Strongly Positive Correlation (r = 0.82; p- value < 0.05). Standard deviation was found to be 27.58 and 107.64 for GFR and ERPF (display), respectively. Our result indicated that the use of 99mTc-DTPA measure ERPF was not recommended.

  4. Three Dimensional Computer Graphics Federates for the 2012 Smackdown Simulation

    NASA Technical Reports Server (NTRS)

    Fordyce, Crystal; Govindaiah, Swetha; Muratet, Sean; O'Neil, Daniel A.; Schricker, Bradley C.

    2012-01-01

    The Simulation Interoperability Standards Organization (SISO) Smackdown is a two-year old annual event held at the 2012 Spring Simulation Interoperability Workshop (SIW). A primary objective of the Smackdown event is to provide college students with hands-on experience in developing distributed simulations using High Level Architecture (HLA). Participating for the second time, the University of Alabama in Huntsville (UAHuntsville) deployed four federates, two federates simulated a communications server and a lunar communications satellite with a radio. The other two federates generated 3D computer graphics displays for the communication satellite constellation and for the surface based lunar resupply mission. Using the Light-Weight Java Graphics Library, the satellite display federate presented a lunar-texture mapped sphere of the moon and four Telemetry Data Relay Satellites (TDRS), which received object attributes from the lunar communications satellite federate to drive their motion. The surface mission display federate was an enhanced version of the federate developed by ForwardSim, Inc. for the 2011 Smackdown simulation. Enhancements included a dead-reckoning algorithm and a visual indication of which communication satellite was in line of sight of Hadley Rille. This paper concentrates on these two federates by describing the functions, algorithms, HLA object attributes received from other federates, development experiences and recommendations for future, participating Smackdown teams.

  5. Optometric measurements predict performance but not comfort on a virtual object placement task with a stereoscopic three-dimensional display

    NASA Astrophysics Data System (ADS)

    McIntire, John P.; Wright, Steve T.; Harrington, Lawrence K.; Havig, Paul R.; Watamaniuk, Scott N. J.; Heft, Eric L.

    2014-06-01

    Twelve participants were tested on a simple virtual object precision placement task while viewing a stereoscopic three-dimensional (S3-D) display. Inclusion criteria included uncorrected or best corrected vision of 20/20 or better in each eye and stereopsis of at least 40 arc sec using the Titmus stereotest. Additionally, binocular function was assessed, including measurements of distant and near phoria (horizontal and vertical) and distant and near horizontal fusion ranges using standard optometric clinical techniques. Before each of six 30 min experimental sessions, measurements of phoria and fusion ranges were repeated using a Keystone View Telebinocular and an S3-D display, respectively. All participants completed experimental sessions in which the task required the precision placement of a virtual object in depth at the same location as a target object. Subjective discomfort was assessed using the simulator sickness questionnaire. Individual placement accuracy in S3-D trials was significantly correlated with several of the binocular screening outcomes: viewers with larger convergent fusion ranges (measured at near distance), larger total fusion ranges (convergent plus divergent ranges, measured at near distance), and/or lower (better) stereoscopic acuity thresholds were more accurate on the placement task. No screening measures were predictive of subjective discomfort, perhaps due to the low levels of discomfort induced.

  6. Displaying uncertainty: investigating the effects of display format and specificity.

    PubMed

    Bisantz, Ann M; Marsiglio, Stephanie Schinzing; Munch, Jessica

    2005-01-01

    We conducted four studies regarding the representation of probabilistic information. Experiments 1 through 3 compared performance on a simulated stock purchase task, in which information regarding stock profitability was probabilistic. Two variables were manipulated: display format for probabilistic information (blurred and colored icons, linguistic phrases, numeric expressions, and combinations) and specificity level (in which the number and size of discrete steps into which the probabilistic information was mapped differed). Results indicated few performance differences attributable to display format; however, performance did improve with greater specificity. Experiment 4, in which participants generated membership functions corresponding to three display formats, found a high degree of similarity in functions across formats and participants and a strong relationship between the shape of the membership function and the intended meaning of the representation. These results indicate that participants can successfully interpret nonnumeric representations of uncertainty and can use such representations in a manner similar to the way numeric expressions are used in a decision-making task. Actual or potential applications of this research include the use of graphical representations of uncertainty in systems such as command and control and situation displays.

  7. Vessel Sampling and Blood Flow Velocity Distribution With Vessel Diameter for Characterizing the Human Bulbar Conjunctival Microvasculature.

    PubMed

    Wang, Liang; Yuan, Jin; Jiang, Hong; Yan, Wentao; Cintrón-Colón, Hector R; Perez, Victor L; DeBuc, Delia C; Feuer, William J; Wang, Jianhua

    2016-03-01

    This study determined (1) how many vessels (i.e., the vessel sampling) are needed to reliably characterize the bulbar conjunctival microvasculature and (2) if characteristic information can be obtained from the distribution histogram of the blood flow velocity and vessel diameter. Functional slitlamp biomicroscope was used to image hundreds of venules per subject. The bulbar conjunctiva in five healthy human subjects was imaged on six different locations in the temporal bulbar conjunctiva. The histograms of the diameter and velocity were plotted to examine whether the distribution was normal. Standard errors were calculated from the standard deviation and vessel sample size. The ratio of the standard error of the mean over the population mean was used to determine the sample size cutoff. The velocity was plotted as a function of the vessel diameter to display the distribution of the diameter and velocity. The results showed that the sampling size was approximately 15 vessels, which generated a standard error equivalent to 15% of the population mean from the total vessel population. The distributions of the diameter and velocity were not only unimodal, but also somewhat positively skewed and not normal. The blood flow velocity was related to the vessel diameter (r=0.23, P<0.05). This was the first study to determine the sampling size of the vessels and the distribution histogram of the blood flow velocity and vessel diameter, which may lead to a better understanding of the human microvascular system of the bulbar conjunctiva.

  8. Identifying fMRI Model Violations with Lagrange Multiplier Tests

    PubMed Central

    Cassidy, Ben; Long, Christopher J; Rae, Caroline; Solo, Victor

    2013-01-01

    The standard modeling framework in Functional Magnetic Resonance Imaging (fMRI) is predicated on assumptions of linearity, time invariance and stationarity. These assumptions are rarely checked because doing so requires specialised software, although failure to do so can lead to bias and mistaken inference. Identifying model violations is an essential but largely neglected step in standard fMRI data analysis. Using Lagrange Multiplier testing methods we have developed simple and efficient procedures for detecting model violations such as non-linearity, non-stationarity and validity of the common Double Gamma specification for hemodynamic response. These procedures are computationally cheap and can easily be added to a conventional analysis. The test statistic is calculated at each voxel and displayed as a spatial anomaly map which shows regions where a model is violated. The methodology is illustrated with a large number of real data examples. PMID:22542665

  9. Enhancement of the Shared Graphics Workspace.

    DTIC Science & Technology

    1987-12-31

    participants to share videodisc images and computer graphics displayed in color and text and facsimile information displayed in black on amber. They...could annotate the information in up to five * colors and print the annotated version at both sites, using a standard fax machine. The SGWS also used a fax...system to display a document, whether text or photo, the camera scans the document, digitizes the data, and sends it via direct memory access (DMA) to

  10. Human factors considerations in the design and evaluation of moving map displays of ownership on the airport surface

    DOT National Transportation Integrated Search

    2004-09-01

    The Federal Aviation Administration (FAA) has requested human factors guidance to support the new moving map Technical Standard Order (TSO)-C165, Electronic Map Display Equipment for Graphical Depiction of Aircraft Position. This document was develop...

  11. Time to Guide: Evidence for Delayed Attentional Guidance in Contextual Cueing

    PubMed Central

    Kunar, Melina A.; Flusberg, Stephen J.; Wolfe, Jeremy M.

    2008-01-01

    Contextual cueing experiments show that, when displays are repeated, reaction times (RTs) to find a target decrease over time even when the observers are not aware of the repetition. Recent evidence suggests that this benefit in standard contextual cueing tasks is not likely to be due to an improvement in attentional guidance (Kunar, Flusberg, Horowitz & Wolfe, 2007). Nevertheless, we ask whether guidance can help participants find the target in a repeated display, if they are given sufficient time to encode the display. In Experiment 1 we increased the display complexity so that it took participants longer to find the target. Here we found a larger effect of guidance than in a condition with shorter RTs. Experiment 2 gave participants prior exposure to the display context. The data again showed that with more time participants could implement guidance to help find the target, provided that there was something in the search stimuli locations to guide attention to. The data suggest that although the benefit in a standard contextual cueing task is unlikely to be a result of guidance, guidance can play a role if it is given time to develop. PMID:18846248

  12. Time to Guide: Evidence for Delayed Attentional Guidance in Contextual Cueing.

    PubMed

    Kunar, Melina A; Flusberg, Stephen J; Wolfe, Jeremy M

    2008-01-01

    Contextual cueing experiments show that, when displays are repeated, reaction times (RTs) to find a target decrease over time even when the observers are not aware of the repetition. Recent evidence suggests that this benefit in standard contextual cueing tasks is not likely to be due to an improvement in attentional guidance (Kunar, Flusberg, Horowitz & Wolfe, 2007). Nevertheless, we ask whether guidance can help participants find the target in a repeated display, if they are given sufficient time to encode the display. In Experiment 1 we increased the display complexity so that it took participants longer to find the target. Here we found a larger effect of guidance than in a condition with shorter RTs. Experiment 2 gave participants prior exposure to the display context. The data again showed that with more time participants could implement guidance to help find the target, provided that there was something in the search stimuli locations to guide attention to. The data suggest that although the benefit in a standard contextual cueing task is unlikely to be a result of guidance, guidance can play a role if it is given time to develop.

  13. Fusion of Three-Dimensional Echocardiographic Regional Myocardial Strain with Cardiac Computed Tomography for Noninvasive Evaluation of the Hemodynamic Impact of Coronary Stenosis in Patients with Chest Pain.

    PubMed

    Mor-Avi, Victor; Patel, Mita B; Maffessanti, Francesco; Singh, Amita; Medvedofsky, Diego; Zaidi, S Javed; Mediratta, Anuj; Narang, Akhil; Nazir, Noreen; Kachenoura, Nadjia; Lang, Roberto M; Patel, Amit R

    2018-06-01

    Combined evaluation of coronary stenosis and the extent of ischemia is essential in patients with chest pain. Intermediate-grade stenosis on computed tomographic coronary angiography (CTCA) frequently triggers downstream nuclear stress testing. Alternative approaches without stress and/or radiation may have important implications. Myocardial strain measured from echocardiographic images can be used to detect subclinical dysfunction. The authors recently tested the feasibility of fusion of three-dimensional (3D) echocardiography-derived regional resting longitudinal strain with coronary arteries from CTCA to determine the hemodynamic significance of stenosis. The aim of the present study was to validate this approach against accepted reference techniques. Seventy-eight patients with chest pain referred for CTCA who also underwent 3D echocardiography and regadenoson stress computed tomography were prospectively studied. Left ventricular longitudinal strain data (TomTec) were used to generate fused 3D displays and detect resting strain abnormalities (RSAs) in each coronary territory. Computed tomographic coronary angiographic images were interpreted for the presence and severity of stenosis. Fused 3D displays of subendocardial x-ray attenuation were created to detect stress perfusion defects (SPDs). In patients with stenosis >25% in at least one artery, fractional flow reserve was quantified (HeartFlow). RSA as a marker of significant stenosis was validated against two different combined references: stenosis >50% on CTCA and SPDs seen in the same territory (reference standard A) and fractional flow reserve < 0.80 and SPDs in the same territory (reference standard B). Of the 99 arteries with no stenosis >50% and no SPDs, considered as normal, 19 (19%) had RSAs. Conversely, with stenosis >50% and SPDs, RSAs were considerably more frequent (17 of 24 [71%]). The sensitivity, specificity, and accuracy of RSA were 0.71, 0.81, and 0.79, respectively, against reference standard A and 0.83, 0.81, and 0.82 against reference standard B. Fusion of CTCA and 3D echocardiography-derived resting myocardial strain provides combined displays, which may be useful in determination of the hemodynamic or functional impact of coronary abnormalities, without additional ionizing radiation or stress testing. Copyright © 2018 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

  14. Computer output microfilm (FR80) systems software documentation, volume 2

    NASA Technical Reports Server (NTRS)

    1975-01-01

    The system consists of a series of programs which convert digital data from magnetic tapes into alpha-numeric characters, graphic plots, and imagery that is recorded on the face of a cathode ray tube. A special camera photographs the face of the tube on microfilm for subsequent display on a film reader. The applicable documents which apply to this system are delineated. The functional relationship between the system software, the standard insert routines, and the applications programs is described; all the applications programs are described in detail. Instructions for locating those documents are presented along with test preparations sheets for all baseline and/or program modification acceptance tests.

  15. The Comprehensive Microbial Resource.

    PubMed

    Peterson, J D; Umayam, L A; Dickinson, T; Hickey, E K; White, O

    2001-01-01

    One challenge presented by large-scale genome sequencing efforts is effective display of uniform information to the scientific community. The Comprehensive Microbial Resource (CMR) contains robust annotation of all complete microbial genomes and allows for a wide variety of data retrievals. The bacterial information has been placed on the Web at http://www.tigr.org/CMR for retrieval using standard web browsing technology. Retrievals can be based on protein properties such as molecular weight or hydrophobicity, GC-content, functional role assignments and taxonomy. The CMR also has special web-based tools to allow data mining using pre-run homology searches, whole genome dot-plots, batch downloading and traversal across genomes using a variety of datatypes.

  16. Survey of multi-function display and control technology

    NASA Technical Reports Server (NTRS)

    Spiger, R. J.; Farrell, R. J.; Tonkin, M. H.

    1982-01-01

    The NASA orbiter spacecraft incorporates a complex array of systems, displays and controls. The incorporation of discrete dedicated controls into a multi-function display and control system (MFDCS) offers the potential for savings in weight, power, panel space and crew training time. The technology applicable to the development of a MFDCS for orbiter application is surveyed. Technology thought to be applicable presently or in the next five years is highlighted. Areas discussed include display media, data handling and processing, controls and operator interactions and the human factors considerations which are involved in a MFDCS design. Several examples of applicable MFDCS technology are described.

  17. Apollo experience report: Crew station integration. Volume 2: Crew station displays and controls

    NASA Technical Reports Server (NTRS)

    Langdoc, W. A.; Nassman, D. A.

    1975-01-01

    The functional requirements for the Apollo displays and controls system are presented. The configuration of the displays, controls, and panels for both the command module and the lunar module are described, and the design development and operational experience of the displays and controls system are discussed. Pertinent recommendations for future displays and controls system design efforts are made.

  18. Method and apparatus for an optical function generator for seamless tiled displays

    NASA Technical Reports Server (NTRS)

    Johnson, Michael (Inventor); Chen, Chung-Jen (Inventor)

    2004-01-01

    Producing seamless tiled images from multiple displays includes measuring a luminance profile of each of the displays, computing a desired luminance profile for each of the displays, and determining a spatial gradient profile of each of the displays based on the measured luminance profile and the computed desired luminance profile. The determined spatial gradient profile is applied to a spatial filter to be inserted into each of the displays to produce the seamless tiled display image.

  19. Synthesis, characterization and calculated non-linear optical properties of two new chalcones

    NASA Astrophysics Data System (ADS)

    Singh, Ashok Kumar; Saxena, Gunjan; Prasad, Rajendra; Kumar, Abhinav

    2012-06-01

    Two new chalcones viz 3-(4-(benzyloxy)phenyl)-1-(2-hydroxyphenyl)prop-2-en-1-one (1) and 3-(4-chlorophenyl)-1-(2-hydroxyphenyl)prop-2-en-1-one (2) have been prepared and characterized by micro analyses, 1H NMR, IR, UV-Vis spectroscopy and single crystal X-ray. The first static hyperpolarizability (β) for both the compounds has been investigated by density functional theory (DFT). Also, the solvent-induced effects on the non-linear optical properties (NLO) were studied by using self-consistent reaction field (SCRF) method. As the solvent polarity increases, the β value increases monotonically. The electronic absorption bands of both 1 and 2 have been assigned by time dependent density functional theory (TD-DFT). Both the compounds displayed better non-linear optical (NLO) responses than the standard p-nitroaniline (pNA).

  20. Next Generation Flight Displays Using HTML5

    NASA Technical Reports Server (NTRS)

    Greenwood, Brian

    2016-01-01

    The Human Integrated Vehicles and Environments (HIVE) lab at Johnson Space Center (JSC) is focused on bringing together inter-disciplinary talent to design and integrate innovative human interface technologies for next generation manned spacecraft. As part of this objective, my summer internship project centered on an ongoing investigation in to building flight displays using the HTML5 standard. Specifically, the goals of my project were to build and demo "flight-like" crew and wearable displays as well as create a webserver for live systems being developed by the Advanced Exploration Systems (AES) program. In parallel to my project, a LabVIEW application, called a display server, was created by the HIVE that uses an XTCE (XML (Extensible Markup Language) Telemetry and Command Exchange) parser and CCSDS (Consultative Committee for Space Data System) space packet decoder to translate telemetry items sent by the CFS (Core Flight Software) over User Datagram Protocol (UDP). It was the webserver's job to receive these UDP messages and send them to the displays. To accomplish this functionality, I utilized Node.js and the accompanying Express framework. On the display side, I was responsible for creating the power system (AMPS) displays. I did this by using HTML5, CSS and JavaScript to create web pages that could update and change dynamically based on the data they received from the webserver. At this point, I have not started on the commanding, being able to send back to the CFS, portion of the displays but hope to have this functionality working by the completion of my internship. I also created a way to test the webserver's functionality without the display server by making a JavaScript application that read in a comma-separate values (CSV) file and converted it to XML which was then sent over UDP. One of the major requirements of my project was to build everything using as little preexisting code as possible, which I accomplished by only using a handful of JavaScript libraries. As a side project, I created a model of the HIVE lab and Building 29 using SketchUp. I obtained the floorplans of the building from the JSC Geographic Information Systems (GIS), which were computer-aided design (CAD) files, and imported them into SketchUp. I then took those floorplans and created a 3D model of the building from them. Working in conjunction with the Hybrid Reality lab in Building 32, the SketchUp model was imported into Unreal Engine for use with the HTC Vive. Using the Vive, I was able to interact with the model I created in virtual reality (VR). The purpose of this side project was to be able to visualize potential lab layouts and mockup designs as they are in development in order to finalize design decisions. Pending approval, the model that I created will be used in the Build-As-You-Test: Can Hybrid Reality Improve the SE/HSI Design Process project in the fall. Getting the opportunity to work at NASA has been one of the most memorable experiences of my life. Over the course of my internship, I improved my programming and web development abilities substantially. I will take all the skills and experiences I have had while at NASA back to school with me in the fall and hope to pursue a career in the aerospace industry after graduating in the spring.

  1. The VIS-AD data model: Integrating metadata and polymorphic display with a scientific programming language

    NASA Technical Reports Server (NTRS)

    Hibbard, William L.; Dyer, Charles R.; Paul, Brian E.

    1994-01-01

    The VIS-AD data model integrates metadata about the precision of values, including missing data indicators and the way that arrays sample continuous functions, with the data objects of a scientific programming language. The data objects of this data model form a lattice, ordered by the precision with which they approximate mathematical objects. We define a similar lattice of displays and study visualization processes as functions from data lattices to display lattices. Such functions can be applied to visualize data objects of all data types and are thus polymorphic.

  2. Minnesota Academic Standards: Kindergarten

    ERIC Educational Resources Information Center

    Minnesota Department of Education, 2017

    2017-01-01

    This document contains all of the Minnesota kindergarten academic standards in the content areas of Arts, English Language Arts, Mathematics, Science and Social Studies. For each content area there is a short overview followed by a coding diagram of how the standards are organized and displayed. This document is adapted from the official versions…

  3. Group Mirrors to Support Interaction Regulation in Collaborative Problem Solving

    ERIC Educational Resources Information Center

    Jermann, Patrick; Dillenbourg, Pierre

    2008-01-01

    Two experimental studies test the effect of group mirrors upon quantitative and qualitative aspects of participation in collaborative problem solving. Mirroring tools consist of a graphical representation of the group's actions which is dynamically updated and displayed to the collaborators. In addition, metacognitive tools display a standard for…

  4. Reexamination of color vision standards, part II. a computational method to assess the effect of color deficiencies in using ATC displays : final report.

    DOT National Transportation Integrated Search

    2006-03-01

    The previous study showed that many colors were used in air traffic control displays. We also found that colors were used mainly for three purposes: capturing controllers immediate attention, identifying targets, and segmenting information. This r...

  5. Surgical planning for radical prostatectomies using three-dimensional visualization and a virtual reality display system

    NASA Astrophysics Data System (ADS)

    Kay, Paul A.; Robb, Richard A.; King, Bernard F.; Myers, R. P.; Camp, Jon J.

    1995-04-01

    Thousands of radical prostatectomies for prostate cancer are performed each year. Radical prostatectomy is a challenging procedure due to anatomical variability and the adjacency of critical structures, including the external urinary sphincter and neurovascular bundles that subserve erectile function. Because of this, there are significant risks of urinary incontinence and impotence following this procedure. Preoperative interaction with three-dimensional visualization of the important anatomical structures might allow the surgeon to understand important individual anatomical relationships of patients. Such understanding might decrease the rate of morbidities, especially for surgeons in training. Patient specific anatomic data can be obtained from preoperative 3D MRI diagnostic imaging examinations of the prostate gland utilizing endorectal coils and phased array multicoils. The volumes of the important structures can then be segmented using interactive image editing tools and then displayed using 3-D surface rendering algorithms on standard work stations. Anatomic relationships can be visualized using surface displays and 3-D colorwash and transparency to allow internal visualization of hidden structures. Preoperatively a surgeon and radiologist can interactively manipulate the 3-D visualizations. Important anatomical relationships can better be visualized and used to plan the surgery. Postoperatively the 3-D displays can be compared to actual surgical experience and pathologic data. Patients can then be followed to assess the incidence of morbidities. More advanced approaches to visualize these anatomical structures in support of surgical planning will be implemented on virtual reality (VR) display systems. Such realistic displays are `immersive,' and allow surgeons to simultaneously see and manipulate the anatomy, to plan the procedure and to rehearse it in a realistic way. Ultimately the VR systems will be implemented in the operating room (OR) to assist the surgeon in conducting the surgery. Such an implementation will bring to the OR all of the pre-surgical planning data and rehearsal experience in synchrony with the actual patient and operation to optimize the effectiveness and outcome of the procedure.

  6. Primary Atomic Frequency Standards at NIST

    PubMed Central

    Sullivan, D. B.; Bergquist, J. C.; Bollinger, J. J.; Drullinger, R. E.; Itano, W. M.; Jefferts, S. R.; Lee, W. D.; Meekhof, D.; Parker, T. E.; Walls, F. L.; Wineland, D. J.

    2001-01-01

    The development of atomic frequency standards at NIST is discussed and three of the key frequency-standard technologies of the current era are described. For each of these technologies, the most recent NIST implementation of the particular type of standard is described in greater detail. The best relative standard uncertainty achieved to date for a NIST frequency standard is 1.5×10−15. The uncertainties of the most recent NIST standards are displayed relative to the uncertainties of atomic frequency standards of several other countries. PMID:27500017

  7. Are food and drink retailers within NHS venues adhering to NICE Quality standard 94 guidance on childhood obesity? A cross-sectional study of two large secondary care NHS hospitals in England

    PubMed Central

    James, Alice; Birch, Laura; Fletcher, Peter; Pearson, Sally; Boyce, Catherine; Ness, Andy R; Hamilton-Shield, Julian P; Lithander, Fiona E

    2017-01-01

    Objective To assess whether the food and drink retail outlets in two major National Health Service (NHS) district general hospitals in England adhere to quality statements 1–3 of the UK National Institute for Health and Care Excellence (NICE) quality standard 94. Design Cross-sectional, descriptive study to assess the food and drink options available in vending machines, restaurants, cafes and shops in two secondary care hospitals. Main outcome measures Adherence to quality statement 1 whereby the food and drink items available in the vending machines were classified as either healthy or less healthy using the Nutrient Profiling Model (NPM). Compliance with quality statements 2 and 3 was assessed through the measurement of how clearly the shops, cafes and restaurants displayed nutrition information on menus, and the availability and prominent display of healthy food and drink options in retail outlets, respectively. Results Adherence to quality statement 1 was poor. Of the 18 vending machines assessed, only 7 (39%) served both a healthy food and a healthy drink option. Neither hospital was compliant with quality statement 2 wherein nutritional information was not available on menus of food providers in either hospital. There was inconsistent compliance with quality standard 3 whereby healthy food and drink options were prominently displayed in the two main hospital restaurants, but all shops and cafes prioritised the display of unhealthy items. Conclusions Neither hospital was consistently compliant with quality statements 1–3 of the NICE quality standard 94. Improving the availability of healthy foods and drinks while reducing the display and accessibility to less healthy options in NHS venues may improve family awareness of healthy alternatives. Making it easier for parents to direct their children to healthier choices is an ostensibly central component of our healthcare system. PMID:29150472

  8. Computer Graphics in Research: Some State -of-the-Art Systems

    ERIC Educational Resources Information Center

    Reddy, R.; And Others

    1975-01-01

    A description is given of the structure and functional characteristics of three types of interactive computer graphic systems, developed by the Department of Computer Science at Carnegie-Mellon; a high-speed programmable display capable of displaying 50,000 short vectors, flicker free; a shaded-color video display for the display of gray-scale…

  9. Laser Optometric Assessment Of Visual Display Viewability

    NASA Astrophysics Data System (ADS)

    Murch, Gerald M.

    1983-08-01

    Through the technique of laser optometry, measurements of a display user's visual accommodation and binocular convergence were used to assess the visual impact of display color, technology, contrast, and work time. The studies reported here indicate the potential of visual-function measurements as an objective means of improving the design of visual displays.

  10. A novel helper phage for HaloTag-mediated co-display of enzyme and substrate on phage.

    PubMed

    Delespaul, Wouter; Peeters, Yves; Herdewijn, Piet; Robben, Johan

    2015-05-01

    Phage display is an established technique for the molecular evolution of peptides and proteins. For the selection of enzymes based on catalytic activity however, simultaneous coupling of an enzyme and its substrate to the phage surface is required. To facilitate this process of co-display, we developed a new helper phage displaying HaloTag, a modified haloalkane dehalogenase that binds specifically and covalently to functionalized haloalkane ligands. The display of functional HaloTag was demonstrated by capture on streptavidin-coated magnetic beads, after coupling a biotinylated haloalkane ligand, or after on-phage extension of a DNA oligonucleotide primer with a biotinylated nucleotide by phi29 DNA polymerase. We also achieved co-display of HaloTag and phi29 DNA polymerase, thereby opening perspectives for the molecular evolution of this enzyme (and others) towards new substrate specificities. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Cell-surface display of enzymes by the yeast Saccharomyces cerevisiae for synthetic biology.

    PubMed

    Tanaka, Tsutomu; Kondo, Akihiko

    2015-02-01

    In yeast cell-surface displays, functional proteins, such as cellulases, are genetically fused to an anchor protein and expressed on the cell surface. Saccharomyces cerevisiae, which is often utilized as a cell factory for the production of fuels, chemicals, and proteins, is the most commonly used yeast for cell-surface display. To construct yeast cells with a desired function, such as the ability to utilize cellulose as a substrate for bioethanol production, cell-surface display techniques for the efficient expression of enzymes on the cell membrane need to be combined with metabolic engineering approaches for manipulating target pathways within cells. In this Minireview, we summarize the recent progress of biorefinery fields in the development and application of yeast cell-surface displays from a synthetic biology perspective and discuss approaches for further enhancing cell-surface display efficiency. © FEMS 2015. All rights reserved. For permissions, please e-mail: journals.permission@oup.com.

  12. CR softcopy display presets based on optimum visualization of specific findings

    NASA Astrophysics Data System (ADS)

    Andriole, Katherine P.; Gould, Robert G.; Webb, W. R.

    1999-07-01

    The purpose of this research is to assess the utility of providing presets for computed radiography (CR) softcopy display, based not on the window/level settings, but on image processing applied to the image based on optimization for visualization of specific findings, pathologies, etc. Clinical chest images are acquired using an Agfa ADC 70 CR scanner, and transferred over the PACS network to an image processing station which has the capability to perform multiscale contrast equalization. The optimal image processing settings per finding are developed in conjunction with a thoracic radiologist by manipulating the multiscale image contrast amplification algorithm parameters. Softcopy display of images processed with finding-specific settings are compared with the standard default image presentation for fifty cases of each category. Comparison is scored using a five point scale with positive one and two denoting the standard presentation is preferred over the finding-specific presets, negative one and two denoting the finding-specific preset is preferred over the standard presentation, and zero denoting no difference. Presets have been developed for pneumothorax and clinical cases are currently being collected in preparation for formal clinical trials. Subjective assessments indicate a preference for the optimized-preset presentation of images over the standard default, particularly by inexperienced radiology residents and referring clinicians.

  13. Standard Terminal Automation Replacement System Human Factors Review Volume 1

    DOT National Transportation Integrated Search

    1997-12-18

    The Federal Aviation Administration formed a Standard Terminal Automation Replacement : System (STARS) Working Group to identify and resolve human factors concerns with the Early : Display Capability (EDC) system before it is introduced in the field....

  14. Clinical-grade mesenchymal stromal cells produced under various good manufacturing practice processes differ in their immunomodulatory properties: standardization of immune quality controls.

    PubMed

    Menard, Cedric; Pacelli, Luciano; Bassi, Giulio; Dulong, Joelle; Bifari, Francesco; Bezier, Isabelle; Zanoncello, Jasmina; Ricciardi, Mario; Latour, Maelle; Bourin, Philippe; Schrezenmeier, Hubert; Sensebé, Luc; Tarte, Karin; Krampera, Mauro

    2013-06-15

    Clinical-grade mesenchymal stromal cells (MSCs) are usually expanded from bone marrow (BMMSCs) or adipose tissue (ADSCs) using processes mainly differing in the use of fetal calf serum (FCS) or human platelet lysate (PL). We aimed to compare immune modulatory properties of clinical-grade MSCs using a combination of fully standardized in vitro assays. BMMSCs expanded with FCS (BMMSC-FCS) or PL (BMMSC-PL), and ADSC-PL were analyzed in quantitative phenotypic and functional experiments, including their capacity to inhibit the proliferation of T, B, and NK cells. The molecular mechanisms supporting T-cell inhibition were investigated. These parameters were also evaluated after pre-stimulation of MSCs with inflammatory cytokines. BMMSC-FCS, BMMSC-PL, and ADSC-PL displayed significant differences in expression of immunosuppressive and adhesion molecules. Standardized functional assays revealed that resting MSCs inhibited proliferation of T and NK cells, but not B cells. ADSC-PL were the most potent in inhibiting T-cell growth, a property ascribed to interferon-γ-dependent indoleamine 2,3-dioxygenase activity. MSCs did not stimulate allogeneic T cell proliferation but were efficiently lysed by activated NK cells. The systematic use of quantitative and reproducible validation techniques highlights differences in immunological properties of MSCs produced using various clinical-grade processes. ADSC-PL emerge as a promising candidate for future clinical trials.

  15. Clinical-Grade Mesenchymal Stromal Cells Produced Under Various Good Manufacturing Practice Processes Differ in Their Immunomodulatory Properties: Standardization of Immune Quality Controls

    PubMed Central

    Menard, Cedric; Pacelli, Luciano; Bassi, Giulio; Dulong, Joelle; Bifari, Francesco; Bezier, Isabelle; Zanoncello, Jasmina; Ricciardi, Mario; Latour, Maelle; Bourin, Philippe; Schrezenmeier, Hubert; Sensebé, Luc

    2013-01-01

    Clinical-grade mesenchymal stromal cells (MSCs) are usually expanded from bone marrow (BMMSCs) or adipose tissue (ADSCs) using processes mainly differing in the use of fetal calf serum (FCS) or human platelet lysate (PL). We aimed to compare immune modulatory properties of clinical-grade MSCs using a combination of fully standardized in vitro assays. BMMSCs expanded with FCS (BMMSC-FCS) or PL (BMMSC-PL), and ADSC-PL were analyzed in quantitative phenotypic and functional experiments, including their capacity to inhibit the proliferation of T, B, and NK cells. The molecular mechanisms supporting T-cell inhibition were investigated. These parameters were also evaluated after pre-stimulation of MSCs with inflammatory cytokines. BMMSC-FCS, BMMSC-PL, and ADSC-PL displayed significant differences in expression of immunosuppressive and adhesion molecules. Standardized functional assays revealed that resting MSCs inhibited proliferation of T and NK cells, but not B cells. ADSC-PL were the most potent in inhibiting T-cell growth, a property ascribed to interferon-γ-dependent indoleamine 2,3-dioxygenase activity. MSCs did not stimulate allogeneic T cell proliferation but were efficiently lysed by activated NK cells. The systematic use of quantitative and reproducible validation techniques highlights differences in immunological properties of MSCs produced using various clinical-grade processes. ADSC-PL emerge as a promising candidate for future clinical trials. PMID:23339531

  16. Display challenges resulting from the use of wide field of view imaging devices

    NASA Astrophysics Data System (ADS)

    Petty, Gregory J.; Fulton, Jack; Nicholson, Gail; Seals, Ean

    2012-06-01

    As focal plane array technologies advance and imagers increase in resolution, display technology must outpace the imaging improvements in order to adequately represent the complete data collection. Typical display devices tend to have an aspect ratio similar to 4:3 or 16:9, however a breed of Wide Field of View (WFOV) imaging devices exist that skew from the norm with aspect ratios as high as 5:1. This particular quality, when coupled with a high spatial resolution, presents a unique challenge for display devices. Standard display devices must choose between resizing the image data to fit the display and displaying the image data in native resolution and truncating potentially important information. The problem compounds when considering the applications; WFOV high-situationalawareness imagers are sought for space-limited military vehicles. Tradeoffs between these issues are assessed to the image quality of the WFOV sensor.

  17. Biochemical functionalization of peptide nanotubes with phage displayed peptides

    NASA Astrophysics Data System (ADS)

    Swaminathan, Swathi; Cui, Yue

    2016-09-01

    The development of a general approach for the biochemical functionalization of peptide nanotubes (PNTs) could open up existing opportunities in both fundamental studies as well as a variety of applications. PNTs are spontaneously assembled organic nanostructures made from peptides. Phage display has emerged as a powerful approach for identifying selective peptide binding motifs. Here, we demonstrate for the first time the biochemical functionalization of PNTs via peptides identified from a phage display peptide library. The phage-displayed peptides are shown to recognize PNTs. These advances further allow for the development of bifunctional peptides for the capture of bacteria and the self-assembly of silver particles onto PNTs. We anticipate that these results could provide significant opportunities for using PNTs in both fundamental studies and practical applications, including sensors and biosensors nanoelectronics, energy storage devices, drug delivery, and tissue engineering.

  18. Exponential localization of Wannier functions in insulators.

    PubMed

    Brouder, Christian; Panati, Gianluca; Calandra, Matteo; Mourougane, Christophe; Marzari, Nicola

    2007-01-26

    The exponential localization of Wannier functions in two or three dimensions is proven for all insulators that display time-reversal symmetry, settling a long-standing conjecture. Our proof relies on the equivalence between the existence of analytic quasi-Bloch functions and the nullity of the Chern numbers (or of the Hall current) for the system under consideration. The same equivalence implies that Chern insulators cannot display exponentially localized Wannier functions. An explicit condition for the reality of the Wannier functions is identified.

  19. The role of sustained attention and display medium in reading comprehension among adolescents with ADHD and without it.

    PubMed

    Stern, Pnina; Shalev, Lilach

    2013-01-01

    Difficulties in reading comprehension are common in children and adolescents with Attention Deficit/Hyperactivity Disorder (ADHD). The current study aimed at investigating the relation between sustained attention and reading comprehension among adolescents with and without ADHD. Another goal was to examine the impact of two manipulations of the text on the efficiency of reading comprehension: Spacing (standard- vs. double-spacing) and Type of presentation (computer screen vs. hard copy). Reading comprehension of two groups of adolescents (participants with ADHD and normal controls) was assessed and compared in four different conditions (standard printed, spaced printed, standard on computer screen, spaced on computer screen). In addition, participants completed a visual sustained attention task. Significant differences in reading comprehension and in sustained attention were obtained between the two groups. Also, a significant correlation was obtained between sustained attention and reading comprehension. Moreover, a significant interaction was revealed between presentation-type, spacing and level of sustained attention on reading comprehension. Implications for reading intervention and the importance of early assessment of attention functioning are discussed. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. Functional evolution and structural conservation in chimeric cytochromes p450: calibrating a structure-guided approach.

    PubMed

    Otey, Christopher R; Silberg, Jonathan J; Voigt, Christopher A; Endelman, Jeffrey B; Bandara, Geethani; Arnold, Frances H

    2004-03-01

    Recombination generates chimeric proteins whose ability to fold depends on minimizing structural perturbations that result when portions of the sequence are inherited from different parents. These chimeric sequences can display functional properties characteristic of the parents or acquire entirely new functions. Seventeen chimeras were generated from two CYP102 members of the functionally diverse cytochrome p450 family. Chimeras predicted to have limited structural disruption, as defined by the SCHEMA algorithm, displayed CO binding spectra characteristic of folded p450s. Even this small population exhibited significant functional diversity: chimeras displayed altered substrate specificities, a wide range in thermostabilities, up to a 40-fold increase in peroxidase activity, and ability to hydroxylate a substrate toward which neither parent heme domain shows detectable activity. These results suggest that SCHEMA-guided recombination can be used to generate diverse p450s for exploring function evolution within the p450 structural framework.

  1. Effect of display size on utilization of traffic situation display for self-spacing task. [transport aircraft

    NASA Technical Reports Server (NTRS)

    Abbott, T. S.; Moen, G. C.

    1981-01-01

    The weather radar cathode ray tube (CRT) is the prime candidate for presenting cockpit display of traffic information (CDTI) in current, conventionally equipped transport aircraft. Problems may result from this, since the CRT size is not optimized for CDTI applications and the CRT is not in the pilot's primary visual scan area. The impact of display size on the ability of pilots to utilize the traffic information to maintain a specified spacing interval behind a lead aircraft during an approach task was studied. The five display sizes considered are representative of the display hardware configurations of airborne weather radar systems. From a pilot's subjective workload viewpoint, even the smallest display size was usable for performing the self spacing task. From a performane viewpoint, the mean spacing values, which are indicative of how well the pilots were able to perform the task, exhibit the same trends, irrespective of display size; however, the standard deviation of the spacing intervals decreased (performance improves) as the display size increased. Display size, therefore, does have a significant effect on pilot performance.

  2. New portable FELIX 3D display

    NASA Astrophysics Data System (ADS)

    Langhans, Knut; Bezecny, Daniel; Homann, Dennis; Bahr, Detlef; Vogt, Carsten; Blohm, Christian; Scharschmidt, Karl-Heinz

    1998-04-01

    An improved generation of our 'FELIX 3D Display' is presented. This system is compact, light, modular and easy to transport. The created volumetric images consist of many voxels, which are generated in a half-sphere display volume. In that way a spatial object can be displayed occupying a physical space with height, width and depth. The new FELIX generation uses a screen rotating with 20 revolutions per second. This target screen is mounted by an easy to change mechanism making it possible to use appropriate screens for the specific purpose of the display. An acousto-optic deflection unit with an integrated small diode pumped laser draws the images on the spinning screen. Images can consist of up to 10,000 voxels at a refresh rate of 20 Hz. Currently two different hardware systems are investigated. The first one is based on a standard PCMCIA digital/analog converter card as an interface and is controlled by a notebook. The developed software is provided with a graphical user interface enabling several animation features. The second, new prototype is designed to display images created by standard CAD applications. It includes the development of a new high speed hardware interface suitable for state-of-the- art fast and high resolution scanning devices, which require high data rates. A true 3D volume display as described will complement the broad range of 3D visualization tools, such as volume rendering packages, stereoscopic and virtual reality techniques, which have become widely available in recent years. Potential applications for the FELIX 3D display include imaging in the field so fair traffic control, medical imaging, computer aided design, science as well as entertainment.

  3. A visual detection model for DCT coefficient quantization

    NASA Technical Reports Server (NTRS)

    Ahumada, Albert J., Jr.; Watson, Andrew B.

    1994-01-01

    The discrete cosine transform (DCT) is widely used in image compression and is part of the JPEG and MPEG compression standards. The degree of compression and the amount of distortion in the decompressed image are controlled by the quantization of the transform coefficients. The standards do not specify how the DCT coefficients should be quantized. One approach is to set the quantization level for each coefficient so that the quantization error is near the threshold of visibility. Results from previous work are combined to form the current best detection model for DCT coefficient quantization noise. This model predicts sensitivity as a function of display parameters, enabling quantization matrices to be designed for display situations varying in luminance, veiling light, and spatial frequency related conditions (pixel size, viewing distance, and aspect ratio). It also allows arbitrary color space directions for the representation of color. A model-based method of optimizing the quantization matrix for an individual image was developed. The model described above provides visual thresholds for each DCT frequency. These thresholds are adjusted within each block for visual light adaptation and contrast masking. For given quantization matrix, the DCT quantization errors are scaled by the adjusted thresholds to yield perceptual errors. These errors are pooled nonlinearly over the image to yield total perceptual error. With this model one may estimate the quantization matrix for a particular image that yields minimum bit rate for a given total perceptual error, or minimum perceptual error for a given bit rate. Custom matrices for a number of images show clear improvement over image-independent matrices. Custom matrices are compatible with the JPEG standard, which requires transmission of the quantization matrix.

  4. Automatic optical inspection of regular grid patterns with an inspection camera used below the Shannon-Nyquist criterion for optical resolution

    NASA Astrophysics Data System (ADS)

    Ferreira, Flávio P.; Forte, Paulo M. F.; Felgueiras, Paulo E. R.; Bret, Boris P. J.; Belsley, Michael S.; Nunes-Pereira, Eduardo J.

    2017-02-01

    An Automatic Optical Inspection (AOI) system for optical inspection of imaging devices used in automotive industry using an inspecting optics of lower spatial resolution than the device under inspection is described. This system is robust and with no moving parts. The cycle time is small. Its main advantage is that it is capable of detecting and quantifying defects in regular patterns, working below the Shannon-Nyquist criterion for optical resolution, using a single low resolution image sensor. It is easily scalable, which is an important advantage in industrial applications, since the same inspecting sensor can be reused for increasingly higher spatial resolutions of the devices to be inspected. The optical inspection is implemented with a notch multi-band Fourier filter, making the procedure especially fitted for regular patterns, like the ones that can be produced in image displays and Head Up Displays (HUDs). The regular patterns are used in production line only, for inspection purposes. For image displays, functional defects are detected at the level of a sub-image display grid element unit. Functional defects are the ones impairing the function of the display, and are preferred in AOI to the direct geometric imaging, since those are the ones directly related with the end-user experience. The shift in emphasis from geometric imaging to functional imaging is critical, since it is this that allows quantitative inspection, below Shannon-Nyquist. For HUDs, the functional detect detection addresses defects resulting from the combined effect of the image display and the image forming optics.

  5. Isolation of N-linked glycopeptides by hydrazine-functionalized magnetic particles.

    PubMed

    Sun, Shisheng; Yang, Ganglong; Wang, Ting; Wang, Qinzhe; Chen, Chao; Li, Zheng

    2010-04-01

    We introduce a novel combination of magnetic particles with hydrazine chemistry, dubbed as hydrazine-functionalized magnetic particles (HFMP) for isolation of glycopeptides. Four methods have been developed and compared for the production of HFMP by hydrazine modification of the surface of the carboxyl and epoxy-silanized magnetic particles, respectively. The evaluation of the capability and specificity of HFMP as well as the optimization of the coupling condition for capturing of glycoproteins were systematically investigated. The results showed that HFMP prepared by adipic dihydrazide functionalization from carboxyl-silanized magnetic particles (HFCA) displayed the maximum capture capacity and isolated efficiency for glycoprotein. When measured with glycoproteins, the capacity of the HFCA (1 g) for coupling bovine fetuin was 130 +/- 5.3 mg. The capability of this method was also confirmed by successful isolation of all formerly glycosylated peptides from standard glycoproteins and identification of their glycosylation sites, which demonstrated the feasibility of the HFCA as an alternative solid support for isolation of glycoproteins/glycopeptides.

  6. Construct Maps as a Foundation for Standard Setting

    ERIC Educational Resources Information Center

    Wyse, Adam E.

    2013-01-01

    Construct maps are tools that display how the underlying achievement construct upon which one is trying to set cut-scores is related to other information used in the process of standard setting. This article reviews what construct maps are, uses construct maps to provide a conceptual framework to view commonly used standard-setting procedures (the…

  7. Active learning in optics and photonics: Liquid Crystal Display in the do-it-yourself

    NASA Astrophysics Data System (ADS)

    Vauderwange, Oliver; Haiss, Ulrich; Wozniak, Peter; Israel, Kai; Curticapean, Dan

    2015-10-01

    Monitors are in the center of media productions and hold an important function as the main visual interface. Tablets and smartphones are becoming more and more important work tools in the media industry. As an extension to our lecture contents an intensive discussion of different display technologies and its applications is taking place now. The established LCD (Liquid Crystal Display) technology and the promising OLED (Organic Light Emitting Diode) technology are in the focus. The classic LCD is currently the most important display technology. The paper will present how the students should develop sense for display technologies besides the theoretical scientific basics. The workshop focuses increasingly on the technical aspects of the display technology and has the goal of deepening the students understanding of the functionality by building simple Liquid Crystal Displays by themselves. The authors will present their experience in the field of display technologies. A mixture of theoretical and practical lectures has the goal of a deeper understanding in the field of digital color representation and display technologies. The design and development of a suitable learning environment with the required infrastructure is crucial. The main focus of this paper is on the hands-on optics workshop "Liquid Crystal Display in the do-it-yourself".

  8. A Novel Database to Rank and Display Archeomagnetic Intensity Data

    NASA Astrophysics Data System (ADS)

    Donadini, F.; Korhonen, K.; Riisager, P.; Pesonen, L. J.; Kahma, K.

    2005-12-01

    To understand the content and the causes of the changes in the Earth's magnetic field beyond the observatory records one has to rely on archeomagnetic and lake sediment paleomagnetic data. The regional archeointensity curves are often of different quality and temporally variable which hampers the global analysis of the data in terms of dipole vs non-dipole field. We have developed a novel archeointensity database application utilizing MySQL, PHP (PHP Hypertext Preprocessor), and the Generic Mapping Tools (GMT) for ranking and displaying geomagnetic intensity data from the last 12000 years. Our application has the advantage that no specific software is required to query the database and view the results. Querying the database is performed using any Web browser; a fill-out form is used to enter the site location and a minimum ranking value to select the data points to be displayed. The form also features the possibility to select plotting of the data as an archeointensity curve with error bars, and a Virtual Axial Dipole Moment (VADM) or ancient field value (Ba) curve calculated using the CALS7K model (Continuous Archaeomagnetic and Lake Sediment geomagnetic model) of (Korte and Constable, 2005). The results of a query are displayed on a Web page containing a table summarizing the query parameters, a table showing the archeointensity values satisfying the query parameters, and a plot of VADM or Ba as a function of sample age. The database consists of eight related tables. The main one, INTENSITIES, stores the 3704 archeointensity measurements collected from 159 publications as VADM (and VDM when available) and Ba values, including their standard deviations and sampling locations. It also contains the number of samples and specimens measured from each site. The REFS table stores the references to a particular study. The names, latitudes, and longitudes of the regions where the samples were collected are stored in the SITES table. The MATERIALS, METHODS, SPECIMEN_TYPES and DATING_METHODS tables store information about the sample materials, intensity determination methods, specimen types and age determination methods. The SIGMA_COUNT table is used indirectly for ranking data according to the number of samples measured and their standard deviations. Each intensity measurement is assigned a score (0--2) depending on the number of specimens measured and their standard deviations, the intensity determination method, the type of specimens measured and materials. The ranking of each data point is calculated as the sum of the four scores and varies between 0 and 8. Additionally, users can select the parameters that will be included in the ranking.

  9. 49 CFR 221.13 - Marking device display.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... visibility that the end silhouette of a standard box car cannot be seen from 1/2 mile on tangent track by a... with, (2) display on the trailing end of the rear car of that train, and (3) continuously illuminate or... cell activation mechanism complying with paragraph (c) of this section, the marking devices prescribed...

  10. Distinctive Resting State Network Disruptions Among Alzheimer's Disease, Subcortical Vascular Dementia, and Mixed Dementia Patients.

    PubMed

    Kim, Hee Jin; Cha, Jungho; Lee, Jong-Min; Shin, Ji Soo; Jung, Na-Yeon; Kim, Yeo Jin; Choe, Yearn Seong; Lee, Kyung Han; Kim, Sung Tae; Kim, Jae Seung; Lee, Jae Hong; Na, Duk L; Seo, Sang Won

    2016-01-01

    Recent advances in resting-state functional MRI have revealed altered functional networks in Alzheimer's disease (AD), especially those of the default mode network (DMN) and central executive network (CEN). However, few studies have evaluated whether small vessel disease (SVD) or combined amyloid and SVD burdens affect the DMN or CEN. The aim of this study was to evaluate whether SVD or combined amyloid and SVD burdens affect the DMN or CEN. In this cross-sectional study, we investigated the resting-state functional connectivity within DMN and CEN in 37 Pittsburgh compound-B (PiB)(+) AD, 37 PiB(-) subcortical vascular dementia (SVaD), 13 mixed dementia patients, and 65 normal controls. When the resting-state DMN of PiB(+) AD and PiB(-) SVaD patients were compared, the PiB(+) AD patients displayed lower functional connectivity in the inferior parietal lobule while the PiB(-) SVaD patients displayed lower functional connectivity in the medial frontal and superior frontal gyri. Compared to the PiB(-) SVaD or PiB(+) AD, the mixed dementia patients displayed lower functional connectivity within the DMN in the posterior cingulate gyrus. When the resting-state CEN connectivity of PiB(+) AD and PiB(-) SVaD patients were compared, the PiB(-) SVaD patients displayed lower functional connectivity in the anterior insular region. Compared to the PiB(-) SVaD or PiB(+) AD, the mixed dementia patients displayed lower functional connectivity within the CEN in the inferior frontal gyrus. Our findings suggest that in PiB(+) AD and PiB(-) SVaD, there is divergent disruptions in resting-state DMN and CEN. Furthermore, patients with combined amyloid and SVD burdens exhibited more disrupted resting-state DMN and CEN than patients with only amyloid or SVD burden.

  11. The impact of computer display height and desk design on muscle activity during information technology work by young adults.

    PubMed

    Straker, L; Pollock, C; Burgess-Limerick, R; Skoss, R; Coleman, J

    2008-08-01

    Computer display height and desk design are believed to be important workstation features and are included in international standards and guidelines. However, the evidence base for these guidelines is lacking a comparison of neck/shoulder muscle activity during computer and paper tasks and whether forearm support can be provided by desk design. This study measured the spinal and upper limb muscle activity in 36 young adults whilst they worked in different computer display, book and desk conditions. Display height affected spinal muscle activity with paper tasks resulting in greater mean spinal and upper limb muscle activity. A curved desk resulted in increased proximal muscle activity. There was no substantial interaction between display and desk.

  12. Standard Terminal Automation Replacement System Human Factors Review Supporting Documents Volume 2

    DOT National Transportation Integrated Search

    1997-12-18

    The Federal Aviation Administration formed a Standard Terminal Automation Replacement : System (STARS) Working Group to identify and resolve human factors concerns with the Early : Display Capability (EDC) system before it is introduced in the field....

  13. Phage as a template to grow bone mineral nanocrystals.

    PubMed

    Cao, Binrui; Xu, Hong; Mao, Chuanbin

    2014-01-01

    Phage display is a biotechnique that fuses functional peptides on the outer surface of filamentous phage by inserting DNA encoding the peptides into the genes of its coat proteins. The resultant peptide-displayed phage particles have been widely used as biotemplates for the synthesis of functional hybrid nanomaterials. Here, we describe the bioengineering of M13 filamentous phage to surface-display bone mineral (hydroxyapatite (HAP))-nucleating peptides derived from dentin matrix protein-1 and using the engineered phage as a biotemplate to grow HAP nanocrystals.

  14. Digital retrospective motion-mode display and processing of electron beam cine-computed tomography and other cross-sectional cardiac imaging techniques

    NASA Astrophysics Data System (ADS)

    Reed, Judd E.; Rumberger, John A.; Buithieu, Jean; Behrenbeck, Thomas; Breen, Jerome F.; Sheedy, Patrick F., II

    1995-05-01

    Electron beam computed tomography is unparalleled in its ability to consistently produce high quality dynamic images of the human heart. Its use in quantification of left ventricular dynamics is well established in both clinical and research applications. However, the image analysis tools supplied with the scanners offer a limited number of analysis options. They are based on embedded computer systems which have not been significantly upgraded since the scanner was introduced over a decade ago in spite of the explosive improvements in available computer power which have occured during this period. To address these shortcomings, a workstation-based ventricular analysis system has been developed at our institution. This system, which has been in use for over five years, is based on current workstation technology and therefore has benefited from the periodic upgrades in processor performance available to these systems. The dynamic image segmentation component of this system is an interactively supervised, semi-automatic surface identification and tracking system. It characterizes the endocardial and epicardial surfaces of the left ventricle as two concentric 4D hyper-space polyhedrons. Each of these polyhedrons have nearly ten thousand vertices which are deposited into a relational database. The right ventricle is also processed in a similar manner. This database is queried by other custom components which extract ventricular function parameters such as regional ejection fraction and wall stress. The interactive tool which supervises dynamic image segmentation has been enhanced with a temporal domain display. The operator interactively chooses the spatial location of the endpoints of a line segment while the corresponding space/time image is displayed. These images, with content resembling M-Mode echocardiography, benefit form electron beam computed tomography's high spatial and contrast resolution. The segmented surfaces are displayed along with the imagery. These displays give the operator valuable feedback pertaining to the contiguity of the extracted surfaces. As with M-Mode echocardiography, the velocity of moving structures can be easily visualized and measured. However, many views inaccessible to standard transthoracic echocardiography are easily generated. These features have augmented the interpretability of cine electron beam computed tomography and have prompted the recent cloning of this system into an 'omni-directional M-Mode display' system for use in digital post-processing of echocardiographic parasternal short axis tomograms. This enhances the functional assessment in orthogonal views of the left ventricle, accounting for shape changes particularly in the asymmetric post-infarction ventricle. Conclusions: A new tool has been developed for analysis and visualization of cine electron beam computed tomography. It has been found to be very useful in verifying the consistency of myocardial surface definition with a semi-automated segmentation tool. By drawing on M-Mode echocardiography experience, electron beam tomography's interpretability has been enhanced. Use of this feature, in conjunction with the existing image processing tools, will enhance the presentations of data on regional systolic and diastolic functions to clinicians in a format that is familiar to most cardiologists. Additionally, this tool reinforces the advantages of electron beam tomography as a single imaging modality for the assessment of left and right ventricular size, shape, and regional functions.

  15. Flying by Ear: Blind Flight with a Music-Based Artificial Horizon

    NASA Technical Reports Server (NTRS)

    Simpson, Brian D.; Brungart, Douglas S.; Dallman, Ronald C.; Yasky, Richard J., Jr.; Romigh, Griffin

    2008-01-01

    Two experiments were conducted in actual flight operations to evaluate an audio artificial horizon display that imposed aircraft attitude information on pilot-selected music. The first experiment examined a pilot's ability to identify, with vision obscured, a change in aircraft roll or pitch, with and without the audio artificial horizon display. The results suggest that the audio horizon display improves the accuracy of attitude identification overall, but differentially affects response time across conditions. In the second experiment, subject pilots performed recoveries from displaced aircraft attitudes using either standard visual instruments, or, with vision obscured, the audio artificial horizon display. The results suggest that subjects were able to maneuver the aircraft to within its safety envelope. Overall, pilots were able to benefit from the display, suggesting that such a display could help to improve overall safety in general aviation.

  16. Studies on hand-held visual communication device for the deaf and speech-impaired I. Visual display window size.

    PubMed

    Thurlow, W R

    1980-01-01

    Messages were presented which moved from right to left along an electronic alphabetic display which was varied in "window" size from 4 through 32 letter spaces. Deaf subjects signed the messages they perceived. Relatively few errors were made even at the highest rate of presentation, which corresponded to a typing rate of 60 words/min. It is concluded that many deaf persons can make effective use of a small visual display. A reduced cost is then possible for visual communication instruments for these people through reduced display size. Deaf subjects who can profit from a small display can be located by a sentence test administered by tape recorder which drives the display of the communication device by means of the standard code of the deaf teletype network.

  17. Addressing Theory and Performance Enhancements for the Independent Sustain and Address AC Plasma Display

    NASA Astrophysics Data System (ADS)

    Warren, Kevin Wilson

    The Independent Sustain and Address (ISA) AC plasma panel is a flat, flicker-free, gas discharge type of display device. This display technology promises to reduce both the cost of manufacturing and operation of AC plasma displays. The ISA technology uses a vastly different mechanism to change the state of the display pixels than the standard AC plasma technology. This addressing mechanism is an exploitation of some of the natural characteristics associated with the plasma that can form during strong gas discharges. This thesis presents detailed data from experiments that were designed to evaluate and test the effectiveness of this mechanism. Through these experiments, the theory that the addressing methodology is based upon is developed and evaluated. These experiments show that the address margin windows for this technology are very large, minimally two to three times larger than the address margins for the standard XY AC plasma addressing techniques. New capabilities are also described, such as global brightness control for the ISA technology and a technique for increasing the addressing rate. These advances were designed into working prototypes and transferred to industry where there are currently commercial products available based upon these advances. A technique for implementing gray scale using some of these advances is also proposed.

  18. Comparison between the standard and a new alternative format of the Summary-of-Findings tables in Cochrane review users: study protocol for a randomized controlled trial.

    PubMed

    Carrasco-Labra, Alonso; Brignardello-Petersen, Romina; Santesso, Nancy; Neumann, Ignacio; Mustafa, Reem A; Mbuagbaw, Lawrence; Ikobaltzeta, Itziar Etxeandia; De Stio, Catherine; McCullagh, Lauren J; Alonso-Coello, Pablo; Meerpohl, Joerg J; Vandvik, Per Olav; Brozek, Jan L; Akl, Elie A; Bossuyt, Patrick; Churchill, Rachel; Glenton, Claire; Rosenbaum, Sarah; Tugwell, Peter; Welch, Vivian; Guyatt, Gordon; Schünemann, Holger

    2015-04-16

    Systematic reviews represent one of the most important tools for knowledge translation but users often struggle with understanding and interpreting their results. GRADE Summary-of-Findings tables have been developed to display results of systematic reviews in a concise and transparent manner. The current format of the Summary-of-Findings tables for presenting risks and quality of evidence improves understanding and assists users with finding key information from the systematic review. However, it has been suggested that additional methods to present risks and display results in the Summary-of-Findings tables are needed. We will conduct a non-inferiority parallel-armed randomized controlled trial to determine whether an alternative format to present risks and display Summary-of-Findings tables is not inferior compared to the current standard format. We will measure participant understanding, accessibility of the information, satisfaction, and preference for both formats. We will invite systematic review users to participate (that is clinicians, guideline developers, and researchers). The data collection process will be undertaken using the online 'Survey Monkey' system. For the primary outcome understanding, non-inferiority of the alternative format (Table A) to the current standard format (Table C) of Summary-of-Findings tables will be claimed if the upper limit of a 1-sided 95% confidence interval (for the difference of proportion of participants answering correctly a given question) excluded a difference in favor of the current format of more than 10%. This study represents an effort to provide systematic reviewers with additional options to display review results using Summary-of-Findings tables. In this way, review authors will have a variety of methods to present risks and more flexibility to choose the most appropriate table features to display (that is optional columns, risks expressions, complementary methods to display continuous outcomes, and so on). NCT02022631 (21 December 2013).

  19. MACMULTIVIEW 5.1

    NASA Technical Reports Server (NTRS)

    Norikane, L.

    1994-01-01

    MacMultiview is an interactive tool for the Macintosh II family which allows one to display and make computations utilizing polarimetric radar data collected by the Jet Propulsion Laboratory's imaging SAR (synthetic aperture radar) polarimeter system. The system includes the single-frequency L-band sensor mounted on the NASA CV990 aircraft and its replacement, the multi-frequency P-, L-, and C-band sensors mounted on the NASA DC-8. MacMultiview provides two basic functions: computation of synthesized polarimetric images and computation of polarization signatures. The radar data can be used to compute a variety of images. The total power image displays the sum of the polarized and unpolarized components of the backscatter for each pixel. The magnitude/phase difference image displays the HH (horizontal transmit and horizontal receive polarization) to VV (vertical transmit and vertical receive polarization) phase difference using color. Magnitude is displayed using intensity. The user may also select any transmit and receive polarization combination from which an image is synthesized. This image displays the backscatter which would have been observed had the sensor been configured using the selected transmit and receive polarizations. MacMultiview can also be used to compute polarization signatures, three dimensional plots of backscatter versus transmit and receive polarizations. The standard co-polarization signatures (transmit and receive polarizations are the same) and cross-polarization signatures (transmit and receive polarizations are orthogonal) can be plotted for any rectangular subset of pixels within a radar data set. In addition, the ratio of co- and cross-polarization signatures computed from different subsets within the same data set can also be computed. Computed images can be saved in a variety of formats: byte format (headerless format which saves the image as a string of byte values), MacMultiview (a byte image preceded by an ASCII header), and PICT2 format (standard format readable by MacMultiview and other image processing programs for the Macintosh). Images can also be printed on PostScript output devices. Polarization signatures can be saved in either a PICT format or as a text file containing PostScript commands and printed on any QuickDraw output device. The associated Stokes matrices can be stored in a text file. MacMultiview is written in C-language for Macintosh II series computers. MacMultiview will only run on Macintosh II series computers with 8-bit video displays (gray shades or color). The program also requires a minimum configuration of System 6.0, Finder 6.1, and 1Mb of RAM. MacMultiview is NOT compatible with System 7.0. It requires 32-Bit QuickDraw. Note: MacMultiview may not be fully compatible with preliminary versions of 32-Bit QuickDraw. Macintosh Programmer's Workshop and Macintosh Programmer's Workshop C (version 3.0) are required for recompiling and relinking. The standard distribution medium for this package is a set of three 800K 3.5 inch diskettes in Macintosh format. This program was developed in 1989 and updated in 1991. MacMultiview is a copyrighted work with all copyright vested in NASA. QuickDraw, Finder, Macintosh, and System 7 are trademarks of Apple Computer, Inc.

  20. Using Python Packages in 6D (Py)Ferret: EOF Analysis, OPeNDAP Sequence Data

    NASA Astrophysics Data System (ADS)

    Smith, K. M.; Manke, A.; Hankin, S. C.

    2012-12-01

    PyFerret was designed to provide the easy methods of access, analysis, and display of data found in the Ferret under the simple yet powerful Python scripting/programming language. This has enabled PyFerret to take advantage of a large and expanding collection of third-party scientific Python modules. Furthermore, ensemble and forecast axes have been added to Ferret and PyFerret for creating and working with collections of related data in Ferret's delayed-evaluation and minimal-data-access mode of operation. These axes simplify processing and visualization of these collections of related data. As one example, an empirical orthogonal function (EOF) analysis Python module was developed, taking advantage of the linear algebra module and other standard functionality in NumPy for efficient numerical array processing. This EOF analysis module is used in a Ferret function to provide an ensemble of levels of data explained by each EOF and Time Amplitude Function (TAF) product. Another example makes use of the PyDAP Python module to provide OPeNDAP sequence data for use in Ferret with minimal data access characteristic of Ferret.

  1. Goal-driven modulation of stimulus-driven attentional capture in multiple-cue displays.

    PubMed

    Richard, Christian M; Wright, Richard D; Ward, Lawrence M

    2003-08-01

    Six location-cuing experiments were conducted to examine the goal-driven control of attentional capture in multiple-cue displays. In most of the experiments, the cue display consisted of the simultaneous presentation of a red direct cue that was highly predictive of the target location (the unique cue) and three gray direct cues (the standard cues) that were not predictive of the location. The results indicated that although target responses were faster at all cued locations relative to uncued locations, they were significantly faster at the unique-cue location than at the standard-cue locations. Other results suggest that the faster responses produced by direct cues may be associated with two different components: an attention-related component that can be modulated by goal-driven factors and a nonattentional component that occurs in parallel at multiple direct-cue locations and is minimally affected by the same goal-driven factors.

  2. SeeGH--a software tool for visualization of whole genome array comparative genomic hybridization data.

    PubMed

    Chi, Bryan; DeLeeuw, Ronald J; Coe, Bradley P; MacAulay, Calum; Lam, Wan L

    2004-02-09

    Array comparative genomic hybridization (CGH) is a technique which detects copy number differences in DNA segments. Complete sequencing of the human genome and the development of an array representing a tiling set of tens of thousands of DNA segments spanning the entire human genome has made high resolution copy number analysis throughout the genome possible. Since array CGH provides signal ratio for each DNA segment, visualization would require the reassembly of individual data points into chromosome profiles. We have developed a visualization tool for displaying whole genome array CGH data in the context of chromosomal location. SeeGH is an application that translates spot signal ratio data from array CGH experiments to displays of high resolution chromosome profiles. Data is imported from a simple tab delimited text file obtained from standard microarray image analysis software. SeeGH processes the signal ratio data and graphically displays it in a conventional CGH karyotype diagram with the added features of magnification and DNA segment annotation. In this process, SeeGH imports the data into a database, calculates the average ratio and standard deviation for each replicate spot, and links them to chromosome regions for graphical display. Once the data is displayed, users have the option of hiding or flagging DNA segments based on user defined criteria, and retrieve annotation information such as clone name, NCBI sequence accession number, ratio, base pair position on the chromosome, and standard deviation. SeeGH represents a novel software tool used to view and analyze array CGH data. The software gives users the ability to view the data in an overall genomic view as well as magnify specific chromosomal regions facilitating the precise localization of genetic alterations. SeeGH is easily installed and runs on Microsoft Windows 2000 or later environments.

  3. A hairpin within YAP mRNA 3′UTR functions in regulation at post-transcription level

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gao, Yuen; Wang, Yuan; Feng, Jinyan

    2015-04-03

    The central dogma of gene expression is that DNA is transcribed into messenger RNAs, which in turn serve as the template for protein synthesis. Recently, it has been reported that mRNAs display regulatory roles that rely on their ability to compete for microRNA binding, independent of their protein-coding function. However, the regulatory mechanism of mRNAs remains poorly understood. Here, we report that a hairpin within YAP mRNA 3′untranslated region (3′UTR) functions in regulation at post-transcription level through generating endogenous siRNAs (esiRNAs). Bioinformatics analysis for secondary structure showed that YAP mRNA displayed a hairpin structure (termed standard hairpin, S-hairpin) within itsmore » 3′UTR. Surprisingly, we observed that the overexpression of S-hairpin derived from YAP 3′UTR (YAP-sh) increased the luciferase reporter activities of transcriptional factor NF-κB and AP-1 in 293T cells. Moreover, we identified that a fragment from YAP-sh, an esiRNA, was able to target mRNA 3′UTR of NF2 (a member of Hippo-signaling pathway) and YAP mRNA 3′UTR itself in hepatoma cells. Thus, we conclude that the YAP-sh within YAP mRNA 3′UTR may serve as a novel regulatory element, which functions in regulation at post-transcription level. Our finding provides new insights into the mechanism of mRNAs in regulatory function. - Highlights: • An S-hairpin within YAP mRNA 3′UTR possesses regulatory function. • YAP-sh acts as a regulatory element for YAP at post-transcription level. • YAP-sh-3p20, an esiRNA derived from YAP-sh, targets mRNAs of YAP and NF2. • YAP-sh-3p20 depresses the proliferation of HepG2 cells in vitro.« less

  4. Circadian Disruption and Diet-Induced Obesity Synergize to Promote Development of β-Cell Failure and Diabetes in Male Rats

    PubMed Central

    Qian, Jingyi; Yeh, Bonnie; Rakshit, Kuntol; Colwell, Christopher S.

    2015-01-01

    There are clear epidemiological associations between circadian disruption, obesity, and pathogenesis of type 2 diabetes. The mechanisms driving these associations are unclear. In the current study, we hypothesized that continuous exposure to constant light (LL) compromises pancreatic β-cell functional and morphological adaption to diet-induced obesity leading to development of type 2 diabetes. To address this hypothesis, we studied wild type Sprague Dawley as well as Period-1 luciferase reporter transgenic rats (Per1-Luc) for 10 weeks under standard light-dark cycle (LD) or LL with concomitant ad libitum access to either standard chow or 60% high-fat diet (HFD). Exposure to HFD led to a comparable increase in food intake, body weight, and adiposity in both LD- and LL-treated rats. However, LL rats displayed profound loss of behavioral circadian rhythms as well as disrupted pancreatic islet clock function characterized by the impairment in the amplitude and the phase islet clock oscillations. Under LD cycle, HFD did not adversely alter diurnal glycemia, diurnal insulinemia, β-cell secretory function as well as β-cell survival, indicating successful adaptation to increased metabolic demand. In contrast, concomitant exposure to LL and HFD resulted in development of hyperglycemia characterized by loss of diurnal changes in insulin secretion, compromised β-cell function, and induction of β-cell apoptosis. This study suggests that circadian disruption and diet-induced obesity synergize to promote development of β-cell failure, likely mediated as a consequence of impaired islet clock function. PMID:26348474

  5. Development and manufacture of visor for helmet-mounted display

    NASA Astrophysics Data System (ADS)

    Krevor, David H.; McNelly, Gregg; Skubon, John; Speirs, Robert

    2004-01-01

    The manufacturing design and process development for the Visor for the JHMCS (Joint Helmet Mounted Cueing System) are discussed. The JHMCS system is a Helmet Mounted Display (HMD) system currently flying on the F-15, F-16 and F/A-18 aircraft. The Visor manufacturing processes are essential to both system performance and economy. The Visor functions both as the system optical combiner and personal protective equipment for the pilot. The Visor material is optical polycarbonate. For a military HMD system, the mechanical and environmental properties of the Visor are as necessary as the optical properties. The visor must meet stringent dimensional requirements to assure adequate system optical performance. Injection molding can provide dimensional fidelity to the requirements, if done properly. Concurrent design of the visor and the tool (i.e., the injection mold) is essential. The concurrent design necessarily considers manufacturing operations and the use environment of the Visor. Computer modeling of the molding process is a necessary input to the mold design. With proper attention to product design and tool development, it is possible to improve upon published standard dimensional tolerances for molded polycarbonate articles.

  6. Color tunable photonic textiles for wearable display applications

    NASA Astrophysics Data System (ADS)

    Sayed, I.; Berzowska, J.; Skorobogatiy, M.

    2010-04-01

    Integration of optical functionalities such as light emission, processing and collection into flexible woven matrices of fabric have grabbed a lot of attention in the last few years. Photonic textiles frequently involve optical fibers as they can be easily processed together with supporting fabric fibers. This technology finds uses in various fields of application such as interactive clothing, signage, wearable health monitoring sensors and mechanical strain and deformation detectors. Recent development in the field of Photonic Band Gap optical fibers (PBG) could potentially lead to novel photonic textiles applications and techniques. Particularly, plastic PBG Bragg fibers fabricated in our group have strong potential in the field of photonic textiles as they offer many advantages over standard silica fibers at the same low cost. Among many unusual properties of PBG textiles we mention that they are highly reflective, PBG textiles are colored without using any colorants, PBG textiles can change their color by controlling the relative intensities of guided and reflected light, and finally, PBG textiles can change their colors when stretched. Some of the many experimental realization of photonic bandgap fiber textiles and their potential applications in wearable displays are discussed.

  7. Evaluation of graphic cardiovascular display in a high-fidelity simulator.

    PubMed

    Agutter, James; Drews, Frank; Syroid, Noah; Westneskow, Dwayne; Albert, Rob; Strayer, David; Bermudez, Julio; Weinger, Matthew B

    2003-11-01

    "Human error" in anesthesia can be attributed to misleading information from patient monitors or to the physician's failure to recognize a pattern. A graphic representation of monitored data may provide better support for detection, diagnosis, and treatment. We designed a graphic display to show hemodynamic variables. Twenty anesthesiologists were asked to assume care of a simulated patient. Half the participants used the graphic cardiovascular display; the other half used a Datex As/3 monitor. One scenario was a total hip replacement with a transfusion reaction to mismatched blood. The second scenario was a radical prostatectomy with 1.5 L of blood loss and myocardial ischemia. Subjects who used the graphic display detected myocardial ischemia 2 min sooner than those who did not use the display. Treatment was initiated sooner (2.5 versus 4.9 min). There were no significant differences between groups in the hip replacement scenario. Systolic blood pressure deviated less from baseline, central venous pressure was closer to its baseline, and arterial oxygen saturation was higher at the end of the case when the graphic display was used. The study lends some support for the hypothesis that providing clinical information graphically in a display designed with emergent features and functional relationships can improve clinicians' ability to detect, diagnose, manage, and treat critical cardiovascular events in a simulated environment. A graphic representation of monitored data may provide better support for detection, diagnosis, and treatment. A user-centered design process led to a novel object-oriented graphic display of hemodynamic variables containing emergent features and functional relationships. In a simulated environment, this display appeared to support clinicians' ability to diagnose, manage, and treat a critical cardiovascular event in a simulated environment. We designed a graphic display to show hemodynamic variables. The study provides some support for the hypothesis that providing clinical information graphically in a display designed with emergent features and functional relationships can improve clinicians' ability to detect, diagnosis, mange, and treat critical cardiovascular events in a simulated environment.

  8. Manometric assessment of idiopathic megarectum in constipated children

    PubMed Central

    Chiarioni, Giuseppe; de Roberto, Giuseppe; Mazzocchi, Alessandro; Morelli, Antonio; Bassotti, Gabrio

    2005-01-01

    AIM: Chronic constipation is a frequent finding in children. In this age range, the concomitant occurrence of megarectum is not uncommon. However, the definition of megarectum is variable, and a few data exist for Italy. We studied anorectal manometric variables and sensation in a group of constipated children with megarectum defined by radiologic criteria. Data from this group were compared with those obtained in a similar group of children with recurrent abdominal pain. METHODS: Anorectal testing was carried out in both groups by standard manometric technique and rectal balloon expulsion test. RESULTS: Megarectum patients displayed discrete abnormalities of anorectal variables and sensation with respect to controls. In particular, the pelvic floor function appeared to be impaired in most patients. CONCLUSION: Constipated children with megarectum have abnormal anorectal function and sensation. These findings may be helpful for a better understanding of the pathophysiological basis of this condition. PMID:16273619

  9. Language Display: Authenticating Claims to Social Identity.

    ERIC Educational Resources Information Center

    Eastman, Carol M.; Stein, Roberta F.

    1993-01-01

    Discusses "language display," a language use strategy whereby members of one group lay claims to attributes associated with another, conveying messages of social, professional, ethnic identity. Examples from academia, politics, business, and advertising reveal language display functions as artifact of crossing linguistic boundaries…

  10. MACSIGMA0 - MACINTOSH TOOL FOR ANALYZING JPL AIRSAR, ERS-1, JERS-1, AND MAGELLAN MIDR DATA

    NASA Technical Reports Server (NTRS)

    Norikane, L.

    1994-01-01

    MacSigma0 is an interactive tool for the Macintosh which allows you to display and make computations from radar data collected by the following sensors: the JPL AIRSAR, ERS-1, JERS-1, and Magellan. The JPL AIRSAR system is a multi-polarimetric airborne synthetic aperture radar developed and operated by the Jet Propulsion Laboratory. It includes the single-frequency L-band sensor mounted on the NASA CV990 aircraft and its replacement, the multi-frequency P-, L-, and C-band sensors mounted on the NASA DC-8. MacSigma0 works with data in the standard JPL AIRSAR output product format, the compressed Stokes matrix format. ERS-1 and JERS-1 are single-frequency, single-polarization spaceborne synthetic aperture radars launched by the European Space Agency and NASDA respectively. To be usable by MacSigma0, The data must have been processed at the Alaska SAR Facility and must be in the "low-resolution" format. Magellan is a spacecraft mission to map the surface of Venus with imaging radar. The project is managed by the Jet Propulsion Laboratory. The spacecraft carries a single-frequency, single-polarization synthetic aperture radar. MacSigma0 works with framelets of the standard MIDR CD-ROM data products. MacSigma0 provides four basic functions: synthesis of images (if necessary), statistical analysis of selected areas, analysis of corner reflectors as a calibration measure (if appropriate and possible), and informative mouse tracking. For instance, the JPL AIRSAR data can be used to synthesize a variety of images such as a total power image. The total power image displays the sum of the polarized and unpolarized components of the backscatter for each pixel. Other images which can be synthesized are HH, HV, VV, RL, RR, HHVV*, HHHV*, HVVV*, HHVV* phase and correlation coefficient images. For the complex and phase images, phase is displayed using color and magnitude is displayed using intensity. MacSigma0 can also be used to compute statistics from within a selected area. The statistics computed depend on the image type. For JPL AIRSAR data, the HH, HV, VV, HHVV* phase, and correlation coefficient means and standard deviation measures are calculated. The mean, relative standard deviation, minimum, and maximum values are calculated for all other data types. A histogram of the selected area is also calculated and displayed. The selected area can be rectangular, linear, or polygonal in shape. The user is allowed to select multiple rectangular areas, but not multiple linear or polygonal areas. The statistics and histogram are displayed to the user and can either be printed or saved as a text file. MacSigma0 can also be used to analyze corner reflectors as a measure of the calibration for JPL AIRSAR, ERS-1, and JERS-1 data types. It computes a theoretical radar cross section and the actual radar cross section for a selected trihedral corner reflector. The theoretical cross section, measured cross section, their ratio in dBs, and other information are displayed to the user and can be saved into a text file. For ERS-1, JERS-1, and Magellan data, MacSigma0 simultaneously displays pixel location in data coordinates and in latitude, longitude coordinates. It also displays sigma0, the incidence angle (for Magellan data), the original pixel value (for Magellan data), and the noise power value (for ERS-1 and JERS-1 data). Grey scale computed images can be saved in a byte format (a headerless format which saves the image as a string of byte values) or a PICT format (a standard format readable by other image processing programs for the Macintosh). Images can also be printed. MacSigma0 is written in C-language for use on Macintosh series computers. The minimum configuration requirements for MacSigma0 are System 6.0, Finder 6.1, 1Mb of RAM, and at least a 4-bit color or grey-scale graphics display. MacSigma0 is also System 7 compatible. To compile the source code, Apple's Macintosh Programmers Workbench (MPW) 3.2 and the MPW C language compiler version 3.2 are required. The source code will not compile with a later version of the compiler; however, the compiled application which will run under the minimum hardware configuration is provided on the distribution medium. In addition, the distribution media includes an executable which runs significantly faster but requires a 68881 compatible math coprocessor and a 68020 compatible CPU. Since JPL AIRSAR data files can be very large, it is often desirable to reduce the size of a data file before transferring it to the Macintosh for use in MacSigma0. A small FORTRAN program which can be used for this purpose is included on the distribution media. MacSigma0 will print statistics on any output device which supports QuickDraw, and it will print images on any device which supports QuickDraw or PostScript. The standard distribution medium for MacSigma0 is a set of five 1.4Mb Macintosh format diskettes. This program was developed in 1992 and is a copyrighted work with all copyright vested in NASA. Version 4.2 of MacSigma0 was released in 1993.

  11. Accelerometer Method and Apparatus for Integral Display and Control Functions

    NASA Technical Reports Server (NTRS)

    Bozeman, Richard J., Jr. (Inventor)

    1996-01-01

    Method and apparatus for detecting mechanical vibrations and outputting a signal in response thereto. Art accelerometer package having integral display and control functions is suitable for mounting upon the machinery to be monitored. Display circuitry provides signals to a bar graph display which may be used to monitor machine conditions over a period of time. Control switches may be set which correspond to elements in the bar graph to provide an alert if vibration signals increase in amplitude over a selected trip point. The circuitry is shock mounted within the accelerometer housing. The method provides for outputting a broadband analog accelerometer signal, integrating this signal to produce a velocity signal, integrating and calibrating the velocity signal before application to a display driver, and selecting a trip point at which a digitally compatible output signal is generated.

  12. Accelerometer Method and Apparatus for Integral Display and Control Functions

    NASA Technical Reports Server (NTRS)

    Bozeman, Richard J., Jr. (Inventor)

    1998-01-01

    Method and apparatus for detecting mechanical vibrations and outputting a signal in response thereto is discussed. An accelerometer package having integral display and control functions is suitable for mounting upon the machinery to be monitored. Display circuitry provides signals to a bar graph display which may be used to monitor machine conditions over a period of time. Control switches may be set which correspond to elements in the bar graph to provide an alert if vibration signals increase in amplitude over a selected trip point. The circuitry is shock mounted within the accelerometer housing. The method provides for outputting a broadband analog accelerometer signal, integrating this signal to produce a velocity signal, integrating and calibrating the velocity signal before application to a display driver, and selecting a trip point at which a digitally compatible output signal is generated.

  13. An entropy model to measure heterogeneity of pedestrian crowds using self-propelled agents

    NASA Astrophysics Data System (ADS)

    Rangel-Huerta, A.; Ballinas-Hernández, A. L.; Muñoz-Meléndez, A.

    2017-05-01

    An entropy model to characterize the heterogeneity of a pedestrian crowd in a counter-flow corridor is presented. Pedestrians are modeled as self-propelled autonomous agents that are able to perform maneuvers to avoid collisions based on a set of simple rules of perception and action. An observer can determine a probability distribution function of the displayed behavior of pedestrians based only on external information. Three types of pedestrian are modeled, relaxed, standard and hurried pedestrians depending on their preferences of turn and non-turn when walking. Thus, using these types of pedestrians two crowds can be simulated: homogeneous and heterogeneous crowds. Heterogeneity is measured in this research based on the entropy in function of time. For that, the entropy of a homogeneous crowd comprising standard pedestrians is used as reference. A number of simulations to measure entropy of pedestrian crowds were conducted by varying different combinations of types of pedestrians, initial simulation conditions of macroscopic flow, as well as density of the crowd. Results from these simulations show that our entropy model is sensitive enough to capture the effect of both the initial simulation conditions about the spatial distribution of pedestrians in a corridor, and the composition of a crowd. Also, a relevant finding is that entropy in function of density presents a phase transition in the critical region.

  14. Numerical evaluation of moiré pattern in touch sensor module with electrode mesh structure in oblique view

    NASA Astrophysics Data System (ADS)

    Pournoury, M.; Zamiri, A.; Kim, T. Y.; Yurlov, V.; Oh, K.

    2016-03-01

    Capacitive touch sensor screen with the metal materials has recently become qualified for substitution of ITO; however several obstacles still have to be solved. One of the most important issues is moiré phenomenon. The visibility problem of the metal-mesh, in touch sensor module (TSM) is numerically considered in this paper. Based on human eye contract sensitivity function (CSF), moiré pattern of TSM electrode mesh structure is simulated with MATLAB software for 8 inch screen display in oblique view. Standard deviation of the generated moiré by the superposition of electrode mesh and screen image is calculated to find the optimal parameters which provide the minimum moiré visibility. To create the screen pixel array and mesh electrode, rectangular function is used. The filtered image, in frequency domain, is obtained by multiplication of Fourier transform of the finite mesh pattern (product of screen pixel and mesh electrode) with the calculated CSF function for three different observer distances (L=200, 300 and 400 mm). It is observed that the discrepancy between analytical and numerical results is less than 0.6% for 400 mm viewer distance. Moreover, in the case of oblique view due to considering the thickness of the finite film between mesh electrodes and screen, different points of minimum standard deviation of moiré pattern are predicted compared to normal view.

  15. Project Review: Teleoperation and Time Delays

    NASA Technical Reports Server (NTRS)

    Adelstein, Bernard D.; Ellis, Stephen; Yeom, Kiwon; Kaiser, Mary K.

    2013-01-01

    We plan to study the invariance in the shift in control strategy from continuous control to move-and-wait as a function of latency and control difficulty. To do so we have developed a theoretically understood way of introducing measurable levels of control difficulty using misalignment between display and control axes . We now use this understanding to study the interaction of control difficulty and system latency. We have conducted an experiment to calibrate our imposition of control difficulty using more representative control rotations. We use these levels of difficulty to directly study the interaction of control difficulty with latency. Results suggest a way to generalize latency requirements across control difficulties that should aid establishment of standards for managing latency in teleoperation.

  16. Bandwagon effects and error bars in particle physics

    NASA Astrophysics Data System (ADS)

    Jeng, Monwhea

    2007-02-01

    We study historical records of experiments on particle masses, lifetimes, and widths, both for signs of expectation bias, and to compare actual errors with reported error bars. We show that significant numbers of particle properties exhibit "bandwagon effects": reported values show trends and clustering as a function of the year of publication, rather than random scatter about the mean. While the total amount of clustering is significant, it is also fairly small; most individual particle properties do not display obvious clustering. When differences between experiments are compared with the reported error bars, the deviations do not follow a normal distribution, but instead follow an exponential distribution for up to ten standard deviations.

  17. Calibrated LCD/TFT stimulus presentation for visual psychophysics in fMRI.

    PubMed

    Strasburger, H; Wüstenberg, T; Jäncke, L

    2002-11-15

    Standard projection techniques using liquid crystal (LCD) or thin-film transistor (TFT) technology show drastic distortions in luminance and contrast characteristics across the screen and across grey levels. Common luminance measurement and calibration techniques are not applicable in the vicinity of MRI scanners. With the aid of a fibre optic, we measured screen luminances for the full space of screen position and image grey values and on that basis developed a compensation technique that involves both luminance homogenisation and position-dependent gamma correction. By the technique described, images displayed to a subject in functional MRI can be specified with high precision by a matrix of desired luminance values rather than by local grey value.

  18. The Comprehensive Microbial Resource

    PubMed Central

    Peterson, Jeremy D.; Umayam, Lowell A.; Dickinson, Tanja; Hickey, Erin K.; White, Owen

    2001-01-01

    One challenge presented by large-scale genome sequencing efforts is effective display of uniform information to the scientific community. The Comprehensive Microbial Resource (CMR) contains robust annotation of all complete microbial genomes and allows for a wide variety of data retrievals. The bacterial information has been placed on the Web at http://www.tigr.org/CMR for retrieval using standard web browsing technology. Retrievals can be based on protein properties such as molecular weight or hydrophobicity, GC-content, functional role assignments and taxonomy. The CMR also has special web-based tools to allow data mining using pre-run homology searches, whole genome dot-plots, batch downloading and traversal across genomes using a variety of datatypes. PMID:11125067

  19. HTML 5 Displays for On-Board Flight Systems

    NASA Technical Reports Server (NTRS)

    Silva, Chandika

    2016-01-01

    During my Internship at NASA in the summer of 2016, I was assigned to a project which dealt with developing a web-server that would display telemetry and other system data using HTML 5, JavaScript, and CSS. By doing this, it would be possible to view the data across a variety of screen sizes, and establish a standard that could be used to simplify communication and software development between NASA and other countries. Utilizing a web- approach allowed us to add in more functionality, as well as make the displays more aesthetically pleasing for the users. When I was assigned to this project my main task was to first establish communication with the current display server. This display server would output data from the on-board systems in XML format. Once communication was established I was then asked to create a dynamic telemetry table web page that would update its header and change as new information came in. After this was completed, certain minor functionalities were added to the table such as a hide column and filter by system option. This was more for the purpose of making the table more useful for the users, as they can now filter and view relevant data. Finally my last task was to create a graphical system display for all the systems on the space craft. This was by far the most challenging part of my internship as finding a JavaScript library that was both free and contained useful functions to assist me in my task was difficult. In the end I was able to use the JointJs library and accomplish the task. With the help of my mentor and the HIVE lab team, we were able to establish stable communication with the display server. We also succeeded in creating a fully dynamic telemetry table and in developing a graphical system display for the advanced modular power system. Working in JSC for this internship has taught me a lot about coding in JavaScript and HTML 5. I was also introduced to the concept of developing software as a team, and exposed to the different types of programs that are used to simplify team coding such as GitLab. While in JSC, I took full advantage of and attended the lectures that were held here on site. I learned a lot about what it is NASA does and about the interesting projects that are conducted here. One of the lectures I attended was about the selection process and the criteria that is used to select future astronauts for flight missions. This truly had an impact on my future plans as it showed me that this path was a viable option for me. After this internship I plan on completing my undergraduate course work and plan to move on for a masters degree. However, during the time in which I will be completing my masters course work, I would like to apply for the NASA pathways graduate program and, if I am accepted, eventually move on to being a full time civil servant. Working in NASA has not only been enjoyable, but full of information and great experiences that have motivated me to seek a full time employment here in the near future.

  20. Therapeutic Antibodies by Phage Display.

    PubMed

    Shim, Hyunbo

    2016-01-01

    Antibody phage display is a major technological platform for the generation of fully human antibodies for therapeutic purposes. The in vitro binder selection by phage display allows researchers to have more extensive control over binding parameters and facilitates the isolation of clinical candidate antibodies with desired binding and/or functional profiles. Since the invention of antibody phage display in late 1980s, significant technological advancements in the design, construction, and selection of the antibody libraries have been made, and several fully human antibodies generated by phage display are currently approved or in various clinical development stages. In this review, the background and details of antibody phage display technology, and representative antibody libraries with natural or synthetic sequence diversity and different construction strategies are described. The generation, optimization, functional and biophysical properties, and preclinical and clinical developments of some of the phage display-derived therapeutic antibodies approved for use in patients or in late-stage clinical trials are also discussed. With evolving novel disease targets and therapeutic strategies, antibody phage display is expected to continue to play a central role in the development of the next generation of therapeutic antibodies. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  1. Awareness, Use, and Perceived Impact of Selected Stakeholders toward the Implementation of Skills Standards in the State of Illinois

    ERIC Educational Resources Information Center

    Bragg, Debra D.; Marvel, Matthew R.

    2008-01-01

    This study examined differences in the awareness, use, and perceived impact of educators, employers, and workforce training providers toward skills standards implementation in the State of Illinois. Group differences were revealed on the use of skills standards, with educators displaying significantly higher levels of use than employers or…

  2. CyDNA: Synthesis and Replication of Highly Cy-Dye Substituted DNA by an Evolved Polymerase

    PubMed Central

    2010-01-01

    DNA not only transmits genetic information but can also serve as a versatile supramolecular scaffold. Here we describe a strategy for the synthesis and replication of DNA displaying hundreds of substituents using directed evolution of polymerase function by short-patch compartmentalized self-replication (spCSR) and the widely used fluorescent dye labeled deoxinucleotide triphosphates Cy3-dCTP and Cy5-dCTP as substrates. In just two rounds of spCSR selection, we have isolated a polymerase that allows the PCR amplification of double stranded DNA fragments up to 1kb, in which all dC bases are substituted by its fluorescent dye-labeled equivalent Cy3- or Cy5-dC. The resulting “CyDNA” displays hundreds of aromatic heterocycles on the outside of the DNA helix and is brightly colored and highly fluorescent. CyDNA also exhibits significantly altered physicochemical properties compared to standard B-form DNA, including loss of silica and intercalating dye binding, resistance to cleavage by some endonucleases, an up to 40% increased apparent diameter as judged by atomic force microscopy and organic phase partitioning during phenol extraction. CyDNA also displays very bright fluorescence enabling significant signal gains in microarray and microfluidic applications. CyDNA represents a step toward a long-term goal of the encoded synthesis of DNA-based polymers of programmable and evolvable sequence and properties. PMID:20235594

  3. CyDNA: synthesis and replication of highly Cy-dye substituted DNA by an evolved polymerase.

    PubMed

    Ramsay, Nicola; Jemth, Ann-Sofie; Brown, Anthony; Crampton, Neal; Dear, Paul; Holliger, Philipp

    2010-04-14

    DNA not only transmits genetic information but can also serve as a versatile supramolecular scaffold. Here we describe a strategy for the synthesis and replication of DNA displaying hundreds of substituents using directed evolution of polymerase function by short-patch compartmentalized self-replication (spCSR) and the widely used fluorescent dye labeled deoxinucleotide triphosphates Cy3-dCTP and Cy5-dCTP as substrates. In just two rounds of spCSR selection, we have isolated a polymerase that allows the PCR amplification of double stranded DNA fragments up to 1kb, in which all dC bases are substituted by its fluorescent dye-labeled equivalent Cy3- or Cy5-dC. The resulting "CyDNA" displays hundreds of aromatic heterocycles on the outside of the DNA helix and is brightly colored and highly fluorescent. CyDNA also exhibits significantly altered physicochemical properties compared to standard B-form DNA, including loss of silica and intercalating dye binding, resistance to cleavage by some endonucleases, an up to 40% increased apparent diameter as judged by atomic force microscopy and organic phase partitioning during phenol extraction. CyDNA also displays very bright fluorescence enabling significant signal gains in microarray and microfluidic applications. CyDNA represents a step toward a long-term goal of the encoded synthesis of DNA-based polymers of programmable and evolvable sequence and properties.

  4. Controlling the Display of Capsule Endoscopy Video for Diagnostic Assistance

    NASA Astrophysics Data System (ADS)

    Vu, Hai; Echigo, Tomio; Sagawa, Ryusuke; Yagi, Keiko; Shiba, Masatsugu; Higuchi, Kazuhide; Arakawa, Tetsuo; Yagi, Yasushi

    Interpretations by physicians of capsule endoscopy image sequences captured over periods of 7-8 hours usually require 45 to 120 minutes of extreme concentration. This paper describes a novel method to reduce diagnostic time by automatically controlling the display frame rate. Unlike existing techniques, this method displays original images with no skipping of frames. The sequence can be played at a high frame rate in stable regions to save time. Then, in regions with rough changes, the speed is decreased to more conveniently ascertain suspicious findings. To realize such a system, cue information about the disparity of consecutive frames, including color similarity and motion displacements is extracted. A decision tree utilizes these features to classify the states of the image acquisitions. For each classified state, the delay time between frames is calculated by parametric functions. A scheme selecting the optimal parameters set determined from assessments by physicians is deployed. Experiments involved clinical evaluations to investigate the effectiveness of this method compared to a standard-view using an existing system. Results from logged action based analysis show that compared with an existing system the proposed method reduced diagnostic time to around 32.5 ± minutes per full sequence while the number of abnormalities found was similar. As well, physicians needed less effort because of the systems efficient operability. The results of the evaluations should convince physicians that they can safely use this method and obtain reduced diagnostic times.

  5. Effect of Display Factors on Chinese Reading Times, Comprehension Scores and Preferences

    ERIC Educational Resources Information Center

    Chan, A.H.S.; Lee, P.S.K.

    2005-01-01

    This paper presents the results of research on elemental standard reading time estimates for traditional Chinese characters on computer displays and explores the factors that may affect the time estimates. Seventy-two native Chinese readers, aged 19 to 24, were asked to read 16 simple passages and then answer four multiple-choice questions.…

  6. Automated Real-Time Behavioral and Physiological Data Acquisition and Display Integrated with Stimulus Presentation for fMRI

    PubMed Central

    Voyvodic, James T.; Glover, Gary H.; Greve, Douglas; Gadde, Syam

    2011-01-01

    Functional magnetic resonance imaging (fMRI) is based on correlating blood oxygen-level dependent (BOLD) signal fluctuations in the brain with other time-varying signals. Although the most common reference for correlation is the timing of a behavioral task performed during the scan, many other behavioral and physiological variables can also influence fMRI signals. Variations in cardiac and respiratory functions in particular are known to contribute significant BOLD signal fluctuations. Variables such as skin conduction, eye movements, and other measures that may be relevant to task performance can also be correlated with BOLD signals and can therefore be used in image analysis to differentiate multiple components in complex brain activity signals. Combining real-time recording and data management of multiple behavioral and physiological signals in a way that can be routinely used with any task stimulus paradigm is a non-trivial software design problem. Here we discuss software methods that allow users control of paradigm-specific audio–visual or other task stimuli combined with automated simultaneous recording of multi-channel behavioral and physiological response variables, all synchronized with sub-millisecond temporal accuracy. We also discuss the implementation and importance of real-time display feedback to ensure data quality of all recorded variables. Finally, we discuss standards and formats for storage of temporal covariate data and its integration into fMRI image analysis. These neuroinformatics methods have been adopted for behavioral task control at all sites in the Functional Biomedical Informatics Research Network (FBIRN) multi-center fMRI study. PMID:22232596

  7. Softcopy quality ruler method: implementation and validation

    NASA Astrophysics Data System (ADS)

    Jin, Elaine W.; Keelan, Brian W.; Chen, Junqing; Phillips, Jonathan B.; Chen, Ying

    2009-01-01

    A softcopy quality ruler method was implemented for the International Imaging Industry Association (I3A) Camera Phone Image Quality (CPIQ) Initiative. This work extends ISO 20462 Part 3 by virtue of creating reference digital images of known subjective image quality, complimenting the hardcopy Standard Reference Stimuli (SRS). The softcopy ruler method was developed using images from a Canon EOS 1Ds Mark II D-SLR digital still camera (DSC) and a Kodak P880 point-and-shoot DSC. Images were viewed on an Apple 30in Cinema Display at a viewing distance of 34 inches. Ruler images were made for 16 scenes. Thirty ruler images were generated for each scene, representing ISO 20462 Standard Quality Scale (SQS) values of approximately 2 to 31 at an increment of one just noticeable difference (JND) by adjusting the system modulation transfer function (MTF). A Matlab GUI was developed to display the ruler and test images side-by-side with a user-adjustable ruler level controlled by a slider. A validation study was performed at Kodak, Vista Point Technology, and Aptina Imaging in which all three companies set up a similar viewing lab to run the softcopy ruler method. The results show that the three sets of data are in reasonable agreement with each other, with the differences within the range expected from observer variability. Compared to previous implementations of the quality ruler, the slider-based user interface allows approximately 2x faster assessments with 21.6% better precision.

  8. Maser: one-stop platform for NGS big data from analysis to visualization

    PubMed Central

    Kinjo, Sonoko; Monma, Norikazu; Misu, Sadahiko; Kitamura, Norikazu; Imoto, Junichi; Yoshitake, Kazutoshi; Gojobori, Takashi; Ikeo, Kazuho

    2018-01-01

    Abstract A major challenge in analyzing the data from high-throughput next-generation sequencing (NGS) is how to handle the huge amounts of data and variety of NGS tools and visualize the resultant outputs. To address these issues, we developed a cloud-based data analysis platform, Maser (Management and Analysis System for Enormous Reads), and an original genome browser, Genome Explorer (GE). Maser enables users to manage up to 2 terabytes of data to conduct analyses with easy graphical user interface operations and offers analysis pipelines in which several individual tools are combined as a single pipeline for very common and standard analyses. GE automatically visualizes genome assembly and mapping results output from Maser pipelines, without requiring additional data upload. With this function, the Maser pipelines can graphically display the results output from all the embedded tools and mapping results in a web browser. Therefore Maser realized a more user-friendly analysis platform especially for beginners by improving graphical display and providing the selected standard pipelines that work with built-in genome browser. In addition, all the analyses executed on Maser are recorded in the analysis history, helping users to trace and repeat the analyses. The entire process of analysis and its histories can be shared with collaborators or opened to the public. In conclusion, our system is useful for managing, analyzing, and visualizing NGS data and achieves traceability, reproducibility, and transparency of NGS analysis. Database URL: http://cell-innovation.nig.ac.jp/maser/ PMID:29688385

  9. Continuation of research into software for space operations support: Conversion of the display manager to X Windows/Motif, volume 2

    NASA Technical Reports Server (NTRS)

    Collier, Mark D.; Killough, Ronnie; Martin, Nancy L.

    1990-01-01

    NASA is currently using a set of applications called the Display Builder and Display Manager. They run on Concurrent systems and heavily depend on the Graphic Kernel System (GKS). At this time however, these two applications would more appropriately be developed in X Windows, in which a low X is used for all actual text and graphics display and a standard widget set (such as Motif) is used for the user interface. Use of the X Windows will increase performance, improve the user interface, enhance portability, and improve reliability. Prototype of X Window/Motif based Display Manager provides the following advantages over a GKS based application: improved performance by using a low level X Windows, display of graphic and text will be more efficient; improved user interface by using Motif; Improved portability by operating on both Concurrent and Sun workstations; and Improved reliability.

  10. Realizing Rec. 2020 color gamut with quantum dot displays.

    PubMed

    Zhu, Ruidong; Luo, Zhenyue; Chen, Haiwei; Dong, Yajie; Wu, Shin-Tson

    2015-09-07

    We analyze how to realize Rec. 2020 wide color gamut with quantum dots. For photoluminescence, our simulation indicates that we are able to achieve over 97% of the Rec. 2020 standard with quantum dots by optimizing the emission spectra and redesigning the color filters. For electroluminescence, by optimizing the emission spectra of quantum dots is adequate to render over 97% of the Rec. 2020 standard. We also analyze the efficiency and angular performance of these devices, and then compare results with LCDs using green and red phosphors-based LED backlight. Our results indicate that quantum dot display is an outstanding candidate for achieving wide color gamut and high optical efficiency.

  11. Level densities and γ-ray strength functions in Sn isotopes

    NASA Astrophysics Data System (ADS)

    Toft, H. K.; Larsen, A. C.; Agvaanluvsan, U.; Bürger, A.; Guttormsen, M.; Mitchell, G. E.; Nyhus, H. T.; Schiller, A.; Siem, S.; Syed, N. U. H.; Voinov, A.

    2010-06-01

    The nuclear level densities of Sn118,119 and the γ-ray strength functions of Sn116,118,119 below the neutron separation energy are extracted with the Oslo method using the (He3,αγ) and (He3,He3'γ) reactions. The level-density function of Sn119 displays steplike structures. The microcanonical entropies are deduced from the level densities, and the single neutron entropy of Sn119 is determined to be 1.7 ± 0.2 kB. Results from a combinatorial model support the interpretation that some of the low-energy steps in the level density function are caused by neutron pair breaking. An enhancement in all the γ-ray strength functions of Sn116-119, compared to standard models for radiative strength, is observed for the γ-ray energy region of ≃4-11 MeV. These small resonances all have a centroid energy of 8.0(1) MeV and an integrated strength corresponding to 1.7(9)% of the classical Thomas-Reiche-Kuhn sum rule. The Sn resonances may be due to electric dipole neutron skin oscillations or to an enhancement of the giant magnetic dipole resonance.

  12. Smart TV-Smartphone Multiscreen Interactive Middleware for Public Displays.

    PubMed

    Martinez-Pabon, Francisco; Caicedo-Guerrero, Jaime; Ibarra-Samboni, Jhon Jairo; Ramirez-Gonzalez, Gustavo; Hernández-Leo, Davinia

    2015-01-01

    A new generation of public displays demands high interactive and multiscreen features to enrich people's experience in new pervasive environments. Traditionally, research on public display interaction has involved mobile devices as the main characters during the use of personal area network technologies such as Bluetooth or NFC. However, the emergent Smart TV model arises as an interesting alternative for the implementation of a new generation of public displays. This is due to its intrinsic connection capabilities with surrounding devices like smartphones or tablets. Nonetheless, the different approaches proposed by the most important vendors are still underdeveloped to support multiscreen and interaction capabilities for modern public displays, because most of them are intended for domestic environments. This research proposes multiscreen interactive middleware for public displays, which was developed from the principles of a loosely coupled interaction model, simplicity, stability, concurrency, low latency, and the usage of open standards and technologies. Moreover, a validation prototype is proposed in one of the most interesting public display scenarios: the advertising.

  13. Smart TV-Smartphone Multiscreen Interactive Middleware for Public Displays

    PubMed Central

    Martinez-Pabon, Francisco; Caicedo-Guerrero, Jaime; Ibarra-Samboni, Jhon Jairo; Ramirez-Gonzalez, Gustavo; Hernández-Leo, Davinia

    2015-01-01

    A new generation of public displays demands high interactive and multiscreen features to enrich people's experience in new pervasive environments. Traditionally, research on public display interaction has involved mobile devices as the main characters during the use of personal area network technologies such as Bluetooth or NFC. However, the emergent Smart TV model arises as an interesting alternative for the implementation of a new generation of public displays. This is due to its intrinsic connection capabilities with surrounding devices like smartphones or tablets. Nonetheless, the different approaches proposed by the most important vendors are still underdeveloped to support multiscreen and interaction capabilities for modern public displays, because most of them are intended for domestic environments. This research proposes multiscreen interactive middleware for public displays, which was developed from the principles of a loosely coupled interaction model, simplicity, stability, concurrency, low latency, and the usage of open standards and technologies. Moreover, a validation prototype is proposed in one of the most interesting public display scenarios: the advertising. PMID:25950018

  14. Data synthesis and display programs for wave distribution function analysis

    NASA Technical Reports Server (NTRS)

    Storey, L. R. O.; Yeh, K. J.

    1992-01-01

    At the National Space Science Data Center (NSSDC) software was written to synthesize and display artificial data for use in developing the methodology of wave distribution analysis. The software comprises two separate interactive programs, one for data synthesis and the other for data display.

  15. Head Up Displays. (Latest Citations from the Aerospace Database)

    NASA Technical Reports Server (NTRS)

    1997-01-01

    The bibliography contains citations concerning the design, fabrication, and applications of head up displays (HUDs). Applications include military aircraft, helicopters, space shuttle, and commercial aircraft. Functions of the display include instrument approach, target tracking, and navigation. The head up display provides for an integrated avionics system with the pilot in the loop. (Contains 50-250 citations and includes a subject term index and title list.)

  16. Head Up Displays. (Latest citations from the Aerospace Database)

    NASA Technical Reports Server (NTRS)

    1996-01-01

    The bibliography contains citations concerning the design, fabrication, and applications of head up displays (HUDs). Applications include military aircraft, helicopters, space shuttle, and commercial aircraft. Functions of the display include instrument approach, target tracking, and navigation. The head up display provides for an integrated avionics system with the pilot in the loop. (Contains 50-250 citations and includes a subject term index and title list.)

  17. Do male breeding displays function to attract mates or defend territories? The explanatory role of mate and site fidelity

    USGS Publications Warehouse

    Lanctot, Richard B.; Sandercock, B.K.; Kempenaers, Bart

    2000-01-01

    Many shorebirds show elaborate breeding displays that include aerial flights and ground displays accompanied by song. The mate attraction hypothesis suggests that breeding displays function to attract mates and maintain pair bonds, whereas the territory defense hypothesis suggests breeding displays function in defining and defending nesting and feeding territories. We tested these hypotheses in the Western Sandpiper (Calidris mauri) by contrasting the duration and level of male breeding displays among pairs that differed in their mate and site fidelity. As predicted by the mate attraction hypothesis, males performed the highest number of song sequences during pair formation, and males paired with their mate of a prior year sang less than males paired to new mates. Further, sitefaithful males mated to a new but experienced mate displayed significantly more than remated males or males new to the area. This suggests a male's prior familiarity with an area and his neighbors does not lessen his display rate as was predicted under the territory defense hypothesis. Limited support for the territory defense hypothesis came from observations of males performing breeding displays with neighboring males along nest territory boundaries. This behavior was short-lived, however, as males abandoned nesting areas after pair-formation and used adjacent or disjointed feeding areas during egg-laying and incubation. Male aggression (i.e., aerial and ground chases), as opposed to breeding displays, appeared to be the principal means of maintaining territory boundaries. Indeed, the rate at which males chased other males remained fairly constant and high throughout the breeding season. Male chasing behavior may also serve as a paternity guard to protect against extra-pair copulations. Our study also found that a female's prior breeding experience in an area correlated with a reduced display rate by her mate, particularly if that mate was new to the area. This indicates female characteristics may not only drive nest initiation, as has been shown in other studies, but are important in determining the duration and extent of male display.

  18. Holographic and light-field imaging for augmented reality

    NASA Astrophysics Data System (ADS)

    Lee, Byoungho; Hong, Jong-Young; Jang, Changwon; Jeong, Jinsoo; Lee, Chang-Kun

    2017-02-01

    We discuss on the recent state of the augmented reality (AR) display technology. In order to realize AR, various seethrough three-dimensional (3D) display techniques have been reported. We describe the AR display with 3D functionality such as light-field display and holography. See-through light-field display can be categorized by the optical elements which are used for see-through property: optical elements controlling path of the light-fields and those generating see-through light-field. Holographic display can be also a good candidate for AR display because it can reconstruct wavefront information and provide realistic virtual information. We introduce the see-through holographic display using various optical techniques.

  19. Improvement of Head-Up Display Standards. Volume 5. Head Up Display ILS (Instrument Landing System) Accuracy Flight Tests.

    DTIC Science & Technology

    1987-09-01

    amber system. The front canopy of the NT-33A is cov- ered with an amber plastic sheet; when the front seat pilot low- ers his blue visor, the...tigation of the effect of head-up display symbol dynamic response caracteristics on flying qualities; Task B was an investigation of symbol accuracy...An amber vinyl plastic sheet covered the in- side front half of the NT-33 canopy. Blue snap-on visors were pi ovided to the evaluation pilots. The

  20. The Integrated Mission-Planning Station: Functional Requirements, Aviator-Computer Dialogue, and Human Engineering Design Criteria.

    DTIC Science & Technology

    1983-08-01

    AD- R136 99 THE INTEGRATED MISSION-PLNNING STATION: FUNCTIONAL 1/3 REQUIREMENTS AVIATOR-..(U) RNACAPR SCIENCES INC SANTA BARBARA CA S P ROGERS RUG...Continue on reverse side o necess.ar and identify by btock number) Interactive Systems Aviation Control-Display Functional Require- Plan-Computer...Dialogue Avionics Systems ments Map Display Army Aviation Design Criteria Helicopters M4ission Planning Cartography Digital Map Human Factors Navigation

  1. Biological Templating and the Production of Functional Fibers

    DTIC Science & Technology

    2006-11-01

    technique to express designed functional peptides on the virus surface is so-called phage display . It has been widely used to modify the virus surface...and functionality. By using the phage display technique, short peptides containing 2 to 12 random amino acids can be fused into pIII proteins to... M13 filamentous bacteriophage were spun into continuous microfibers. These fibers can be made out of pure phage solution or a blended solution of

  2. The impact of a highly visible display of cerebral perfusion pressure on outcome in individuals with cerebral aneurysms.

    PubMed

    Kirkness, Catherine J; Burr, Robert L; Cain, Kevin C; Newell, David W; Mitchell, Pamela H

    2008-01-01

    Nurses' ability to rapidly detect decreases in cerebral perfusion pressure (CPP), which may contribute to secondary brain injury, may be limited by poor visibility of CPP displays. To evaluate the impact of a highly visible CPP display on the functional outcome in individuals with cerebral aneurysms. Patients with cerebral aneurysms (n = 100) who underwent continuous CPP monitoring were enrolled and randomized to beds with or without the additional CPP display. Six-month outcome was assessed. Functional outcome was not significantly different between control and intervention groups after controlling for initial neurologic condition (odds ratio .904, 95% confidence interval 0.317 to 2.573). However, greater time below CPP thresholds (55 to 70 mm Hg) was significantly associated with poorer outcome (P = .005 to .010). Although the enhanced CPP display was not associated with significantly better outcome, longer periods of CPP below set levels were associated with poorer outcome.

  3. White constancy method for mobile displays

    NASA Astrophysics Data System (ADS)

    Yum, Ji Young; Park, Hyun Hee; Jang, Seul Ki; Lee, Jae Hyang; Kim, Jong Ho; Yi, Ji Young; Lee, Min Woo

    2014-03-01

    In these days, consumer's needs for image quality of mobile devices are increasing as smartphone is widely used. For example, colors may be perceived differently when displayed contents under different illuminants. Displayed white in incandescent lamp is perceived as bluish, while same content in LED light is perceived as yellowish. When changed in perceived white under illuminant environment, image quality would be degraded. Objective of the proposed white constancy method is restricted to maintain consistent output colors regardless of the illuminants utilized. Human visual experiments are performed to analyze viewers'perceptual constancy. Participants are asked to choose the displayed white in a variety of illuminants. Relationship between the illuminants and the selected colors with white are modeled by mapping function based on the results of human visual experiments. White constancy values for image control are determined on the predesigned functions. Experimental results indicate that propsed method yields better image quality by keeping the display white.

  4. SPAM- SPECTRAL ANALYSIS MANAGER (DEC VAX/VMS VERSION)

    NASA Technical Reports Server (NTRS)

    Solomon, J. E.

    1994-01-01

    The Spectral Analysis Manager (SPAM) was developed to allow easy qualitative analysis of multi-dimensional imaging spectrometer data. Imaging spectrometers provide sufficient spectral sampling to define unique spectral signatures on a per pixel basis. Thus direct material identification becomes possible for geologic studies. SPAM provides a variety of capabilities for carrying out interactive analysis of the massive and complex datasets associated with multispectral remote sensing observations. In addition to normal image processing functions, SPAM provides multiple levels of on-line help, a flexible command interpretation, graceful error recovery, and a program structure which can be implemented in a variety of environments. SPAM was designed to be visually oriented and user friendly with the liberal employment of graphics for rapid and efficient exploratory analysis of imaging spectrometry data. SPAM provides functions to enable arithmetic manipulations of the data, such as normalization, linear mixing, band ratio discrimination, and low-pass filtering. SPAM can be used to examine the spectra of an individual pixel or the average spectra over a number of pixels. SPAM also supports image segmentation, fast spectral signature matching, spectral library usage, mixture analysis, and feature extraction. High speed spectral signature matching is performed by using a binary spectral encoding algorithm to separate and identify mineral components present in the scene. The same binary encoding allows automatic spectral clustering. Spectral data may be entered from a digitizing tablet, stored in a user library, compared to the master library containing mineral standards, and then displayed as a timesequence spectral movie. The output plots, histograms, and stretched histograms produced by SPAM can be sent to a lineprinter, stored as separate RGB disk files, or sent to a Quick Color Recorder. SPAM is written in C for interactive execution and is available for two different machine environments. There is a DEC VAX/VMS version with a central memory requirement of approximately 242K of 8 bit bytes and a machine independent UNIX 4.2 version. The display device currently supported is the Raster Technologies display processor. Other 512 x 512 resolution color display devices, such as De Anza, may be added with minor code modifications. This program was developed in 1986.

  5. SPAM- SPECTRAL ANALYSIS MANAGER (UNIX VERSION)

    NASA Technical Reports Server (NTRS)

    Solomon, J. E.

    1994-01-01

    The Spectral Analysis Manager (SPAM) was developed to allow easy qualitative analysis of multi-dimensional imaging spectrometer data. Imaging spectrometers provide sufficient spectral sampling to define unique spectral signatures on a per pixel basis. Thus direct material identification becomes possible for geologic studies. SPAM provides a variety of capabilities for carrying out interactive analysis of the massive and complex datasets associated with multispectral remote sensing observations. In addition to normal image processing functions, SPAM provides multiple levels of on-line help, a flexible command interpretation, graceful error recovery, and a program structure which can be implemented in a variety of environments. SPAM was designed to be visually oriented and user friendly with the liberal employment of graphics for rapid and efficient exploratory analysis of imaging spectrometry data. SPAM provides functions to enable arithmetic manipulations of the data, such as normalization, linear mixing, band ratio discrimination, and low-pass filtering. SPAM can be used to examine the spectra of an individual pixel or the average spectra over a number of pixels. SPAM also supports image segmentation, fast spectral signature matching, spectral library usage, mixture analysis, and feature extraction. High speed spectral signature matching is performed by using a binary spectral encoding algorithm to separate and identify mineral components present in the scene. The same binary encoding allows automatic spectral clustering. Spectral data may be entered from a digitizing tablet, stored in a user library, compared to the master library containing mineral standards, and then displayed as a timesequence spectral movie. The output plots, histograms, and stretched histograms produced by SPAM can be sent to a lineprinter, stored as separate RGB disk files, or sent to a Quick Color Recorder. SPAM is written in C for interactive execution and is available for two different machine environments. There is a DEC VAX/VMS version with a central memory requirement of approximately 242K of 8 bit bytes and a machine independent UNIX 4.2 version. The display device currently supported is the Raster Technologies display processor. Other 512 x 512 resolution color display devices, such as De Anza, may be added with minor code modifications. This program was developed in 1986.

  6. Development of user guidelines for ECAS display design, volume 1

    NASA Technical Reports Server (NTRS)

    Dodson, D. W.; Shields, N. L., Jr.

    1978-01-01

    Experiment computer application software (ECAS) display design and command usage guidelines were developed, which if followed by spacelab experiments, would standardize methods and techniques for data presentation and commanding via ECAS. These guidelines would provide some commonality among experiments which would enhance crew training and flight operations. The guidelines are applicable to all onboard experiment displays, whether allocated by ECAS or a dedicated experiment processor. A brief description of the spacelab data display system characteristics and of the services provided by the experiment computer operating system is included. Guidelines concerning data presentation and layout of alphanumeric and graphic information are presented along with guidelines concerning keyboard commanding and command feedback.

  7. Toward Software Both Seen and Heard.

    ERIC Educational Resources Information Center

    Lazzaro, Joseph J.

    1996-01-01

    Visually impaired users are hampered by current PC software written for graphical user interfaces. Screen readers that vocalize displayed text require standardization that remains missing in the programming industry; the readers cannot interpret many cues in the Windows environment. More programming standards and adaptive technology for computers…

  8. The Effect of Rotation on Legibility of Dot-Matrix Characters

    DTIC Science & Technology

    1991-02-01

    National Standard for human factors engineering of visual display terminal workstations . Paper presented at the meeting of the Human Factors Society...Ed.), Modern issues in perception (pp. 217-226). Amsterdam: North Holland. Human Factors Society, HFS/ANSI VDT Standards Committee. (1988). American

  9. Magnetic Field Experiment Data Analysis System

    NASA Technical Reports Server (NTRS)

    Holland, D. B.; Zanetti, L. J.; Suther, L. L.; Potemra, T. A.; Anderson, B. J.

    1995-01-01

    The Johns Hopkins University Applied Physics Laboratory (JHU/APL) Magnetic Field Experiment Data Analysis System (MFEDAS) has been developed to process and analyze satellite magnetic field experiment data from the TRIAD, MAGSAT, AMPTE/CCE, Viking, Polar BEAR, DMSP, HILAT, UARS, and Freja satellites. The MFEDAS provides extensive data management and analysis capabilities. The system is based on standard data structures and a standard user interface. The MFEDAS has two major elements: (1) a set of satellite unique telemetry processing programs for uniform and rapid conversion of the raw data to a standard format and (2) the program Magplot which has file handling, data analysis, and data display sections. This system is an example of software reuse, allowing new data sets and software extensions to be added in a cost effective and timely manner. Future additions to the system will include the addition of standard format file import routines, modification of the display routines to use a commercial graphics package based on X-Window protocols, and a generic utility for telemetry data access and conversion.

  10. Young Children's Responses to Guilt Displays

    ERIC Educational Resources Information Center

    Vaish, Amrisha; Carpenter, Malinda; Tomasello, Michael

    2011-01-01

    Displaying guilt after a transgression serves to appease the victim and other group members, restore interpersonal relationships, and indicate the transgressors' awareness of and desire to conform to the group's norms. We investigated whether and when young children are sensitive to these functions of guilt displays. In Study 1, after 4- and…

  11. Reconstructing the Past? Low German and the Creating of Regional Identity in Public Language Display

    ERIC Educational Resources Information Center

    Reershemius, Gertrud

    2011-01-01

    This article deals with language contact between a dominant standard language--German--and a lesser-used variety--Low German--in a situation in which the minoritised language is threatened by language shift and language loss. It analyses the application of Low German in forms of public language display and the self-presentation of the community in…

  12. 45 CFR 155.220 - Ability of States to permit agents and brokers to assist qualified individuals, qualified...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    .... (3) When an Internet Web site of the agent or broker is used to complete the QHP selection, at a minimum the Internet Web site must: (i) Disclose and display all QHP information provided by the Exchange... broker's Internet Web site for a QHP, prominently display a standardized disclaimer provided by HHS...

  13. Vision Algorithms Catch Defects in Screen Displays

    NASA Technical Reports Server (NTRS)

    2014-01-01

    Andrew Watson, a senior scientist at Ames Research Center, developed a tool called the Spatial Standard Observer (SSO), which models human vision for use in robotic applications. Redmond, Washington-based Radiant Zemax LLC licensed the technology from NASA and combined it with its imaging colorimeter system, creating a powerful tool that high-volume manufacturers of flat-panel displays use to catch defects in screens.

  14. 25 CFR 542.33 - What are the minimum internal control standards for surveillance for Tier B gaming operations?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... capability to display the date and time of recorded events on video and/or digital recordings. The displayed... digital record retention. (1) All video recordings and/or digital records of coverage provided by the.... (3) Duly authenticated copies of video recordings and/or digital records shall be provided to the...

  15. 25 CFR 542.33 - What are the minimum internal control standards for surveillance for Tier B gaming operations?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... capability to display the date and time of recorded events on video and/or digital recordings. The displayed... digital record retention. (1) All video recordings and/or digital records of coverage provided by the.... (3) Duly authenticated copies of video recordings and/or digital records shall be provided to the...

  16. 25 CFR 542.33 - What are the minimum internal control standards for surveillance for Tier B gaming operations?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... capability to display the date and time of recorded events on video and/or digital recordings. The displayed... digital record retention. (1) All video recordings and/or digital records of coverage provided by the.... (3) Duly authenticated copies of video recordings and/or digital records shall be provided to the...

  17. 25 CFR 542.33 - What are the minimum internal control standards for surveillance for Tier B gaming operations?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... capability to display the date and time of recorded events on video and/or digital recordings. The displayed... digital record retention. (1) All video recordings and/or digital records of coverage provided by the.... (3) Duly authenticated copies of video recordings and/or digital records shall be provided to the...

  18. 25 CFR 542.33 - What are the minimum internal control standards for surveillance for Tier B gaming operations?

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... capability to display the date and time of recorded events on video and/or digital recordings. The displayed... digital record retention. (1) All video recordings and/or digital records of coverage provided by the.... (3) Duly authenticated copies of video recordings and/or digital records shall be provided to the...

  19. CAVIAR: an R package for checking, displaying and processing wood-formation-monitoring data.

    PubMed

    Rathgeber, Cyrille B K; Santenoise, Philippe; Cuny, Henri E

    2018-05-19

    In the last decade, the pervasive question of climate change impacts on forests has revived investigations on intra-annual dynamics of wood formation, involving disciplines such as plant ecology, tree physiology and dendrochronology. This resulted in the creation of many research groups working on this topic worldwide and a rapid increase in the number of studies and publications. Wood-formation-monitoring studies are generally based on a common conceptual model describing xylem cell formation as the succession of four differentiation phases (cell division, cell enlargement, cell wall thickening and mature cells). They generally use the same sampling techniques, sample preparation methods and anatomical criteria to separate between differentiation zones and discriminate and count forming xylem cells, resulting in very similar raw data. However, the way these raw data are then processed, producing the elaborated data on which statistical analyses are performed, still remains quite specific to each individual study. Thereby, despite very similar raw data, wood-formation-monitoring studies yield results that are still quite difficult to compare. CAVIAR-an R package specifically dedicated to the verification, visualization and manipulation of wood-formation-monitoring data-can help to improve this situation. Initially, CAVIAR was built to provide efficient algorithms to compute critical dates of wood formation phenology for conifers growing in temperate and cold environments. Recently, we developed it further to check, display and process wood-formation-monitoring data. Thanks to new and upgraded functions, raw data can now be consistently verified, standardized and modelled (using logistic regressions and Gompertz functions), in order to describe wood phenology and intra-annual dynamics of tree-ring formation. We believe that CAVIAR will help strengthening the science of wood formation dynamics by effectively contributing to the standardization of its concepts and methods, making thereby possible the comparison between data and results from different studies.

  20. The proportion of unhealthy foodstuffs children are exposed to at the checkout of convenience supermarkets.

    PubMed

    Horsley, Jason A; Absalom, Katie Ar; Akiens, Evie M; Dunk, Robert J; Ferguson, Alice M

    2014-11-01

    To investigate the proportion of foods that are unhealthy to which children are exposed at the checkout of convenience supermarkets. We performed a cross-sectional survey of foodstuffs displayed at the checkout. Products displayed at or below children's eye-level were designated as healthy, unhealthy or unclassifiable using the Food Standards Agency's scoring criteria. Thirteen convenience supermarkets from the three leading UK supermarket chains were selected on the basis of proximity to the town hall in Sheffield, England. Convenience supermarkets were defined as branches of supermarket chains that were identified as being other than superstores on their company's store locator website. In almost all of the convenience supermarkets surveyed, the main healthy product on display was sugar-free chewing gum. On average, when chewing gum was not included as a foodstuff, 89% of the products on display at the checkouts of convenience supermarkets were unhealthy using the Food Standards Agency's criteria. One store was a notable outlier, providing only fruit and nuts at its checkout. The overwhelming majority of products to which children are exposed at the convenience supermarket checkout are unhealthy. This is despite all the supermarket chains surveyed having signed up to the UK Government's 'responsibility deal'.

  1. Active matrix organic light emitting diode (OLED)-XL life test results

    NASA Astrophysics Data System (ADS)

    Fellowes, David A.; Wood, Michael V.; Hastings, Arthur R., Jr.; Ghosh, Amalkumar P.; Prache, Olivier

    2008-04-01

    OLED displays have been known to exhibit high levels of performance with regards to contrast, response time, uniformity, and viewing angle, but a lifetime improvement has been perceived to be essential for broadening the applications of OLED's in the military and in the commercial market. As a result of this need, the US Army and eMagin Corporation established a Cooperative Research and Development Agreement (CRADA) to improve the lifetime of OLED displays. In 2006, eMagin Corporation developed long-life OLED-XL devices for use in their AMOLED microdisplays for head-worn applications, and RDECOM CERDEC NVESD ran life tests on these displays, finding over 200% lifetime improvement for the XL devices over the standard displays. Early results were published at the 2007 SPIE Defense and Security Symposium. Further life testing of XL and standard devices at ambient conditions and at high temperatures will be presented this year along with a recap of previous data. This should result in a better understanding of the applicability of AMOLEDs in military and commercial head mounted systems: where good fits are made, and where further development might be needed. This is a continuation of the paper "Life test results of OLED-XL long-life devices for use in active matrix organic light emitting diode (AMOLED) displays for head mounted applications" presented at SPIE DSS in 2007.

  2. The use of lower resolution viewing devices for mammographic interpretation: implications for education and training.

    PubMed

    Chen, Yan; James, Jonathan J; Turnbull, Anne E; Gale, Alastair G

    2015-10-01

    To establish whether lower resolution, lower cost viewing devices have the potential to deliver mammographic interpretation training. On three occasions over eight months, fourteen consultant radiologists and reporting radiographers read forty challenging digital mammography screening cases on three different displays: a digital mammography workstation, a standard LCD monitor, and a smartphone. Standard image manipulation software was available for use on all three devices. Receiver operating characteristic (ROC) analysis and ANOVA (Analysis of Variance) were used to determine the significance of differences in performance between the viewing devices with/without the application of image manipulation software. The effect of reader's experience was also assessed. Performance was significantly higher (p < .05) on the mammography workstation compared to the other two viewing devices. When image manipulation software was applied to images viewed on the standard LCD monitor, performance improved to mirror levels seen on the mammography workstation with no significant difference between the two. Image interpretation on the smartphone was uniformly poor. Film reader experience had no significant effect on performance across all three viewing devices. Lower resolution standard LCD monitors combined with appropriate image manipulation software are capable of displaying mammographic pathology, and are potentially suitable for delivering mammographic interpretation training. • This study investigates potential devices for training in mammography interpretation. • Lower resolution standard LCD monitors are potentially suitable for mammographic interpretation training. • The effect of image manipulation tools on mammography workstation viewing is insignificant. • Reader experience had no significant effect on performance in all viewing devices. • Smart phones are not suitable for displaying mammograms.

  3. Adapting the design of Anesthesia Information Management Systems to innovations depicted in Industrial Property documents.

    PubMed

    Spyropoulos, B; Tzavaras, A; Zogogianni, D; Botsivaly, M

    2013-01-01

    The purpose of this paper is to present the design and the current development status of an Anesthesia Information Management System (AIMS). For this system, the physical and technical advances, depicted in relevant, recently published Industrial Property documents, have been taken into account. Additional innovative sensors create further data-load to be managed. Novel wireless data-transmission modes demand eventually compliance to further proper standards, so that interoperability between AIMS and the existing Hospital Information Systems is being sustained. We attempted to define, the state-of-the-art concerning the functions, the design-prerequisites and the relevant standards and of an "emerging" AIMS that is combining hardware innovation, real-time data acquisition, processing and displaying and lastly enabling the necessary interoperability with the other components of the existing Hospital Information Systems. Finally, we report based on this approach, about the design and implementation status, of our "real-world" system under development and discuss the multifarious obstacles encountered during this still on-going project.

  4. Quantification of free convection effects on 1 kg mass standards

    NASA Astrophysics Data System (ADS)

    Schreiber, M.; Emran, M. S.; Fröhlich, T.; Schumacher, J.; Thess, A.

    2015-12-01

    We determine the free-convection effects and the resulting mass differences in a high-precision mass comparator for cylindrical and spherical 1 kg mass standards at different air pressures. The temperature differences are chosen in the millikelvin range and lead to microgram updrafts. Our studies reveal a good agreement between the measurements and direct numerical simulations of the Boussinesq equations of free thermal convection. A higher sensitivity to the free convection effects is found for the spherical case compared to the cylindrical one. We also translate our results on the free convection effects into a form which is used in fluid mechanics: a dimensionless updraft coefficient as a function of the dimensionless Grashof number Gr that quantifies the thermal driving due to temperature differences. This relation displays a unique scaling behavior over nearly four decades in Gr and levels off into geometry-specific constants for the very small Grashof numbers. The obtained results provide a rational framework for estimating systematic errors in mass metrology due to the effects of free convection.

  5. Versatile microbial surface-display for environmental remediation and biofuels production

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Cindy H.; Mulchandani, Ashok; Chen, wilfred

    2008-02-14

    Surface display is a powerful technique that utilizes natural microbial functional components to express proteins or peptides on the cell exterior. Since the reporting of the first surface-display system in the mid-1980s, a variety of new systems have been reported for yeast, Gram-positive and Gram-negative bacteria. Non-conventional display methods are emerging, eliminating the generation of genetically modified microorganisms. Cells with surface display are used as biocatalysts, biosorbents and biostimulants. Microbial cell-surface display has proven to be extremely important for numerous applications ranging from combinatorial library screening and protein engineering to bioremediation and biofuels production.

  6. Defective Cell Cycle Checkpoint Functions in Melanoma Are Associated with Altered Patterns of Gene Expression

    PubMed Central

    Kaufmann, William K.; Nevis, Kathleen R.; Qu, Pingping; Ibrahim, Joseph G.; Zhou, Tong; Zhou, Yingchun; Simpson, Dennis A.; Helms-Deaton, Jennifer; Cordeiro-Stone, Marila; Moore, Dominic T.; Thomas, Nancy E.; Hao, Honglin; Liu, Zhi; Shields, Janiel M.; Scott, Glynis A.; Sharpless, Norman E.

    2009-01-01

    Defects in DNA damage responses may underlie genetic instability and malignant progression in melanoma. Cultures of normal human melanocytes (NHMs) and melanoma lines were analyzed to determine whether global patterns of gene expression could predict the efficacy of DNA damage cell cycle checkpoints that arrest growth and suppress genetic instability. NHMs displayed effective G1 and G2 checkpoint responses to ionizing radiation-induced DNA damage. A majority of melanoma cell lines (11/16) displayed significant quantitative defects in one or both checkpoints. Melanomas with B-RAF mutations as a class displayed a significant defect in DNA damage G2 checkpoint function. In contrast the epithelial-like subtype of melanomas with wild-type N-RAS and B-RAF alleles displayed an effective G2 checkpoint but a significant defect in G1 checkpoint function. RNA expression profiling revealed that melanoma lines with defects in the DNA damage G1 checkpoint displayed reduced expression of p53 transcriptional targets, such as CDKN1A and DDB2, and enhanced expression of proliferation-associated genes, such as CDC7 and GEMININ. A Bayesian analysis tool was more accurate than significance analysis of microarrays for predicting checkpoint function using a leave-one-out method. The results suggest that defects in DNA damage checkpoints may be recognized in melanomas through analysis of gene expression. PMID:17597816

  7. Prediction of HDR quality by combining perceptually transformed display measurements with machine learning

    NASA Astrophysics Data System (ADS)

    Choudhury, Anustup; Farrell, Suzanne; Atkins, Robin; Daly, Scott

    2017-09-01

    We present an approach to predict overall HDR display quality as a function of key HDR display parameters. We first performed subjective experiments on a high quality HDR display that explored five key HDR display parameters: maximum luminance, minimum luminance, color gamut, bit-depth and local contrast. Subjects rated overall quality for different combinations of these display parameters. We explored two models | a physical model solely based on physically measured display characteristics and a perceptual model that transforms physical parameters using human vision system models. For the perceptual model, we use a family of metrics based on a recently published color volume model (ICT-CP), which consists of the PQ luminance non-linearity (ST2084) and LMS-based opponent color, as well as an estimate of the display point spread function. To predict overall visual quality, we apply linear regression and machine learning techniques such as Multilayer Perceptron, RBF and SVM networks. We use RMSE and Pearson/Spearman correlation coefficients to quantify performance. We found that the perceptual model is better at predicting subjective quality than the physical model and that SVM is better at prediction than linear regression. The significance and contribution of each display parameter was investigated. In addition, we found that combined parameters such as contrast do not improve prediction. Traditional perceptual models were also evaluated and we found that models based on the PQ non-linearity performed better.

  8. Method and apparatus for calibrating a display using an array of cameras

    NASA Technical Reports Server (NTRS)

    Johnson, Michael J. (Inventor); Chen, Chung-Jen (Inventor); Chandrasekhar, Rajesh (Inventor)

    2001-01-01

    The present invention overcomes many of the disadvantages of the prior art by providing a display that can be calibrated and re-calibrated with a minimal amount of manual intervention. To accomplish this, the present invention provides one or more cameras to capture an image that is projected on a display screen. In one embodiment, the one or more cameras are placed on the same side of the screen as the projectors. In another embodiment, an array of cameras is provided on either or both sides of the screen for capturing a number of adjacent and/or overlapping capture images of the screen. In either of these embodiments, the resulting capture images are processed to identify any non-desirable characteristics including any visible artifacts such as seams, bands, rings, etc. Once the non-desirable characteristics are identified, an appropriate transformation function is determined. The transformation function is used to pre-warp the input video signal to the display such that the non-desirable characteristics are reduced or eliminated from the display. The transformation function preferably compensates for spatial non-uniformity, color non-uniformity, luminance non-uniformity, and/or other visible artifacts.

  9. A database system to support image algorithm evaluation

    NASA Technical Reports Server (NTRS)

    Lien, Y. E.

    1977-01-01

    The design is given of an interactive image database system IMDB, which allows the user to create, retrieve, store, display, and manipulate images through the facility of a high-level, interactive image query (IQ) language. The query language IQ permits the user to define false color functions, pixel value transformations, overlay functions, zoom functions, and windows. The user manipulates the images through generic functions. The user can direct images to display devices for visual and qualitative analysis. Image histograms and pixel value distributions can also be computed to obtain a quantitative analysis of images.

  10. QUICK - AN INTERACTIVE SOFTWARE ENVIRONMENT FOR ENGINEERING DESIGN

    NASA Technical Reports Server (NTRS)

    Schlaifer, R. S.

    1994-01-01

    QUICK provides the computer user with the facilities of a sophisticated desk calculator which can perform scalar, vector and matrix arithmetic, propagate conic orbits, determine planetary and satellite coordinates and perform other related astrodynamic calculations within a Fortran-like environment. QUICK is an interpreter, therefore eliminating the need to use a compiler or a linker to run QUICK code. QUICK capabilities include options for automated printing of results, the ability to submit operating system commands on some systems, and access to a plotting package (MASL)and a text editor without leaving QUICK. Mathematical and programming features of QUICK include the ability to handle arbitrary algebraic expressions, the capability to define user functions in terms of other functions, built-in constants such as pi, direct access to useful COMMON areas, matrix capabilities, extensive use of double precision calculations, and the ability to automatically load user functions from a standard library. The MASL (The Multi-mission Analysis Software Library) plotting package, included in the QUICK package, is a set of FORTRAN 77 compatible subroutines designed to facilitate the plotting of engineering data by allowing programmers to write plotting device independent applications. Its universality lies in the number of plotting devices it puts at the user's disposal. The MASL package of routines has proved very useful and easy to work with, yielding good plots for most new users on the first or second try. The functions provided include routines for creating histograms, "wire mesh" surface plots and contour plots as well as normal graphs with a large variety of axis types. The library has routines for plotting on cartesian, polar, log, mercator, cyclic, calendar, and stereographic axes, and for performing automatic or explicit scaling. The lengths of the axes of a plot are completely under the control of the program using the library. Programs written to use the MASL subroutines can be made to output to the Calcomp 1055 plotter, the Hewlett-Packard 2648 graphics terminal, the HP 7221, 7475 and 7550 pen plotters, the Tektronix 40xx and 41xx series graphics terminals, the DEC VT125/VT240 graphics terminals, the QMS 800 laser printer, the Sun Microsystems monochrome display, the Ridge Computers monochrome display, the IBM/PC color display, or a "dumb" terminal or printer. Programs using this library can be written so that they always use the same type of plotter or they can allow the choice of plotter type to be deferred until after program execution. QUICK is written in RATFOR for use on Sun4 series computers running SunOS. No source code is provided. The standard distribution medium for this program is a .25 inch streaming magnetic tape cartridge in UNIX tar format. An electronic copy of the documentation in ASCII format is included on the distribution medium. QUICK was developed in 1991 and is a copyrighted work with all copyright vested in NASA.

  11. Next generation phage display by use of pVII and pIX as display scaffolds.

    PubMed

    Løset, Geir Åge; Sandlie, Inger

    2012-09-01

    Phage display technology has evolved to become an extremely versatile and powerful platform for protein engineering. The robustness of the phage particle, its ease of handling and its ability to tolerate a range of different capsid fusions are key features that explain the dominance of phage display in combinatorial engineering. Implementation of new technology is likely to ensure the continuation of its success, but has also revealed important short comings inherent to current phage display systems. This is in particular related to the biology of the two most popular display capsids, namely pIII and pVIII. Recent findings using two alternative capsids, pVII and pIX, located to the phage tip opposite that of pIII, suggest how they may be exploited to alleviate or circumvent many of these short comings. This review addresses important aspects of the current phage display standard and then discusses the use of pVII and pIX. These may both complement current systems and be used as alternative scaffolds for display and selection to further improve phage display as the ultimate combinatorial engineering platform. Copyright © 2012 Elsevier Inc. All rights reserved.

  12. Real-time analysis of dual-display phage immobilization and autoantibody screening using quartz crystal microbalance with dissipation monitoring.

    PubMed

    Rajaram, Kaushik; Losada-Pérez, Patricia; Vermeeren, Veronique; Hosseinkhani, Baharak; Wagner, Patrick; Somers, Veerle; Michiels, Luc

    2015-01-01

    Over the last three decades, phage display technology has been used for the display of target-specific biomarkers, peptides, antibodies, etc. Phage display-based assays are mostly limited to the phage ELISA, which is notorious for its high background signal and laborious methodology. These problems have been recently overcome by designing a dual-display phage with two different end functionalities, namely, streptavidin (STV)-binding protein at one end and a rheumatoid arthritis-specific autoantigenic target at the other end. Using this dual-display phage, a much higher sensitivity in screening specificities of autoantibodies in complex serum sample has been detected compared to single-display phage system on phage ELISA. Herein, we aimed to develop a novel, rapid, and sensitive dual-display phage to detect autoantibodies presence in serum samples using quartz crystal microbalance with dissipation monitoring as a sensing platform. The vertical functionalization of the phage over the STV-modified surfaces resulted in clear frequency and dissipation shifts revealing a well-defined viscoelastic signature. Screening for autoantibodies using antihuman IgG-modified surfaces and the dual-display phage with STV magnetic bead complexes allowed to isolate the target entities from complex mixtures and to achieve a large response as compared to negative control samples. This novel dual-display strategy can be a potential alternative to the time consuming phage ELISA protocols for the qualitative analysis of serum autoantibodies and can be taken as a departure point to ultimately achieve a point of care diagnostic system.

  13. Mesoscale and severe storms (Mass) data management and analysis system

    NASA Technical Reports Server (NTRS)

    Hickey, J. S.; Karitani, S.; Dickerson, M.

    1984-01-01

    Progress on the Mesoscale and Severe Storms (MASS) data management and analysis system is described. An interactive atmospheric data base management software package to convert four types of data (Sounding, Single Level, Grid, Image) into standard random access formats is implemented and integrated with the MASS AVE80 Series general purpose plotting and graphics display data analysis software package. An interactive analysis and display graphics software package (AVE80) to analyze large volumes of conventional and satellite derived meteorological data is enhanced to provide imaging/color graphics display utilizing color video hardware integrated into the MASS computer system. Local and remote smart-terminal capability is provided by installing APPLE III computer systems within individual scientist offices and integrated with the MASS system, thus providing color video display, graphics, and characters display of the four data types.

  14. Heightened cortisol response to exercise challenge in women with functional hypothalamic amenorrhea.

    PubMed

    Sanders, Kristen M; Kawwass, Jennifer F; Loucks, Tammy; Berga, Sarah L

    2018-02-01

    Functional hypothalamic amenorrhea is characterized by anovulation caused by reduced gonadotropin-releasing hormone drive and is associated with hypercortisolemia that has been linked to heightened hypothalamic-pituitary-adrenal reactivity to common psychological and metabolic challenges. We hypothesized that women with functional hypothalamic amenorrhea would display greater cortisol responses to exercise challenge than ovulatory women with eumenorrhea. We completed a cross-sectional comparison of 9 women with functional hypothalamic amenorrhea and 11 women with eumenorrhea who were of reproductive age, who weighed 90-110% ideal body weight, who did not exercise excessively, and who had no formal psychiatric diagnosis. Subjects completed a 20-minute submaximal exercise challenge using a cycle ergometer in a research exercise laboratory. Heart rate and circulatory cortisol, glucose, and lactate were measured at 10-minute intervals before, during, and after the exercise challenge. Baseline (t= -10 minutes) cortisol, glucose, lactate, and heart rate were comparable between groups. Glucose levels rose modestly during exercise by 2.9% in women with eumenorrhea (P=.4) but declined by 10.6% in functional hypothalamic amenorrhea (P<.03). The nadir in glucose levels in functional hypothalamic amenorrhea occurred at the end of the 20-minute exercise challenge (t= +20 min). Lactate levels rose comparably in both groups (P<.01). Heart rate increased significantly with exercise in both groups (P<.01), but the increase was smaller in subjects with functional hypothalamic amenorrhea (P<.01). Cortisol levels increased during the exercise challenge in both groups (P<.01) and peaked 10 minutes after the exercise ended (t= +30 min). At peak, subjects with functional hypothalamic amenorrhea displayed higher cortisol levels (147±22 [standard error of the mean] ng/mL) than women with eumenorrhea (96±12 ng/mL; P=.05). The mean percent increase over baseline was 62% in women with eumenorrhea and 92% in functional hypothalamic amenorrhea. The heightened cortisol response to exercise in women with functional hypothalamic amenorrhea was associated with a decline in blood glucose level that was not observed in women with eumenorrhea. Women with functional hypothalamic amenorrhea appear to be more reactive at the endocrine level to the metabolic demand of exercise. Submaximal challenge unmasks underlying stress sensitivity in women with functional hypothalamic amenorrhea and highlights the importance of the use of psychological interventions for stress reduction in this population. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Effect of protein properties on display efficiency using the M13 phage display system.

    PubMed

    Imai, S; Mukai, Y; Takeda, T; Abe, Y; Nagano, K; Kamada, H; Nakagawa, S; Tsunoda, S; Tsutsumi, Y

    2008-10-01

    The M13 phage display system is a powerful technology for engineering proteins such as functional mutant proteins and peptides. In this system, it is necessary that the protein is displayed on the phage surface. Therefore, its application is often limited when a protein is poorly displayed. In this study, we attempted to understand the relationship between a protein's properties and its display efficiency using the well-known pIII and pVIII type phage display system. The display of positively charged SV40 NLS and HIV-1 Tat peptides on pill was less efficient than that of the neutrally charged RGDS peptide. When different molecular weight proteins (1.5-58 kDa) were displayed on pIII and pVIII, their display efficiencies were directly influenced by their molecular weights. These results indicate the usefulness in predicting a desired protein's compatibility with protein and peptide engineering using the phage display system.

  16. Image quality evaluation of medical color and monochrome displays using an imaging colorimeter

    NASA Astrophysics Data System (ADS)

    Roehrig, Hans; Gu, Xiliang; Fan, Jiahua

    2012-10-01

    The purpose of this presentation is to demonstrate the means which permit examining the accuracy of Image Quality with respect to MTF (Modulation Transfer Function) and NPS (Noise Power Spectrum) of Color Displays and Monochrome Displays. Indications were in the past that color displays could affect the clinical performance of color displays negatively compared to monochrome displays. Now colorimeters like the PM-1423 are available which have higher sensitivity and color accuracy than the traditional cameras like CCD cameras. Reference (1) was not based on measurements made with a colorimeter. This paper focuses on the measurements of physical characteristics of the spatial resolution and noise performance of color and monochrome medical displays which were made with a colorimeter and we will after this meeting submit the data to an ROC study so we have again a paper to present at a future SPIE Conference.Specifically, Modulation Transfer Function (MTF) and Noise Power Spectrum (NPS) were evaluated and compared at different digital driving levels (DDL) between the two medical displays. This paper focuses on the measurements of physical characteristics of the spatial resolution and noise performance of color and monochrome medical displays which were made with a colorimeter and we will after this meeting submit the data to an ROC study so we have again a paper to present at a future Annual SPIE Conference. Specifically, Modulation Transfer Function (MTF) and Noise Power Spectrum (NPS) were evaluated and compared at different digital driving levels (DDL) between the two medical displays. The Imaging Colorimeter. Measurement of color image quality needs were done with an imaging colorimeter as it is shown below. Imaging colorimetry is ideally suited to FPD measurement because imaging systems capture spatial data generating millions of data points in a single measurement operation. The imaging colorimeter which was used was the PM-1423 from Radiant Imaging. It uses full-frame CCDs with 100% fill factor which makes it very suitable to measure luminance and chrominance of individual LCD pixels and sub-pixels on an LCD display. The CCDs used are 14-bit thermoelectrically cooled and temperature stabilized , scientific grade.

  17. Mass data graphics requirements for symbol generators: example 2D airport navagation and 3D terrain function

    NASA Astrophysics Data System (ADS)

    Schiefele, Jens; Bader, Joachim; Kastner, S.; Wiesemann, Thorsten; von Viebahn, Harro

    2002-07-01

    Next generation of cockpit display systems will display mass data. Mass data includes terrain, obstacle, and airport databases. Display formats will be two and eventually 3D. A prerequisite for the introduction of these new functions is the availability of certified graphics hardware. The paper describes functionality and required features of an aviation certified 2D/3D graphics board. This graphics board should be based on low-level and hi-level API calls. These graphic calls should be very similar to OpenGL. All software and the API must be aviation certified. As an example application, a 2D airport navigation function and a 3D terrain visualization is presented. The airport navigation format is based on highly precise airport database following EUROCAE ED-99/RTCA DO-272 specifications. Terrain resolution is based on EUROCAE ED-98/RTCA DO-276 requirements.

  18. Effect of color visualization and display hardware on the visual assessment of pseudocolor medical images

    PubMed Central

    Zabala-Travers, Silvina; Choi, Mina; Cheng, Wei-Chung

    2015-01-01

    Purpose: Even though the use of color in the interpretation of medical images has increased significantly in recent years, the ad hoc manner in which color is handled and the lack of standard approaches have been associated with suboptimal and inconsistent diagnostic decisions with a negative impact on patient treatment and prognosis. The purpose of this study is to determine if the choice of color scale and display device hardware affects the visual assessment of patterns that have the characteristics of functional medical images. Methods: Perfusion magnetic resonance imaging (MRI) was the basis for designing and performing experiments. Synthetic images resembling brain dynamic-contrast enhanced MRI consisting of scaled mixtures of white, lumpy, and clustered backgrounds were used to assess the performance of a rainbow (“jet”), a heated black-body (“hot”), and a gray (“gray”) color scale with display devices of different quality on the detection of small changes in color intensity. The authors used a two-alternative, forced-choice design where readers were presented with 600 pairs of images. Each pair consisted of two images of the same pattern flipped along the vertical axis with a small difference in intensity. Readers were asked to select the image with the highest intensity. Three differences in intensity were tested on four display devices: a medical-grade three-million-pixel display, a consumer-grade monitor, a tablet device, and a phone. Results: The estimates of percent correct show that jet outperformed hot and gray in the high and low range of the color scales for all devices with a maximum difference in performance of 18% (confidence intervals: 6%, 30%). Performance with hot was different for high and low intensity, comparable to jet for the high range, and worse than gray for lower intensity values. Similar performance was seen between devices using jet and hot, while gray performance was better for handheld devices. Time of performance was shorter with jet. Conclusions: Our findings demonstrate that the choice of color scale and display hardware affects the visual comparative analysis of pseudocolor images. Follow-up studies in clinical settings are being considered to confirm the results with patient images. PMID:26127048

  19. Integrated cockpit display and processor: the best solution for Link-16 applications

    NASA Astrophysics Data System (ADS)

    Smeyne, Alan L.; Savaya, John

    2000-08-01

    Link-16 Data Link systems are being added to current avionics systems to provide increased situational awareness and command data. By using a single intelligent display system, the impact to existing aircraft systems to implement Link-16 capabilities is minimized. Litton Guidance & Control Systems (G&CS), a military avionics supplier for more than forty years, provides Open System Architecture (OSA), large screen aircraft display systems. Based on a common set of plug-in modules, these Smart Multi-Function Displays (SMFD) are available in a variety of sizes and processing capabilities, any one of which can meet the Link-16 requirements. Using a single smart SMFD connected to a Link-16 subsystem has many advantages. With digital moving map capability, the SMFD can monitor and display air and ground tracks of both friendly and hostile forces while providing potential threat data to the operator. The SMFD can also monitor vehicle status and mission data to share between friendly air and surface forces. To support the integrated digital battlefield, Link-16 capability is required and the Litton G&CS SMFD provides the processing/display functionality to implement this capability.

  20. Psychophysical contrast calibration

    PubMed Central

    To, Long; Woods, Russell L; Goldstein, Robert B; Peli, Eli

    2013-01-01

    Electronic displays and computer systems offer numerous advantages for clinical vision testing. Laboratory and clinical measurements of various functions and in particular of (letter) contrast sensitivity require accurately calibrated display contrast. In the laboratory this is achieved using expensive light meters. We developed and evaluated a novel method that uses only psychophysical responses of a person with normal vision to calibrate the luminance contrast of displays for experimental and clinical applications. Our method combines psychophysical techniques (1) for detection (and thus elimination or reduction) of display saturating nonlinearities; (2) for luminance (gamma function) estimation and linearization without use of a photometer; and (3) to measure without a photometer the luminance ratios of the display’s three color channels that are used in a bit-stealing procedure to expand the luminance resolution of the display. Using a photometer we verified that the calibration achieved with this procedure is accurate for both LCD and CRT displays enabling testing of letter contrast sensitivity to 0.5%. Our visual calibration procedure enables clinical, internet and home implementation and calibration verification of electronic contrast testing. PMID:23643843

  1. Molecular characterization of the silencing complex SIR in Candida glabrata hyperadherent clinical isolates.

    PubMed

    Leiva-Peláez, Osney; Gutiérrez-Escobedo, Guadalupe; López-Fuentes, Eunice; Cruz-Mora, José; De Las Peñas, Alejandro; Castaño, Irene

    2018-05-29

    An important virulence factor for the fungal pathogen Candida glabrata is the ability to adhere to the host cells, which is mediated by the expression of adhesins. Epa1 is responsible for ∼95% of the in vitro adherence to epithelial cells and is the founding member of the Epa family of adhesins. The majority of EPA genes are localized close to different telomeres, which causes transcriptional repression due to subtelomeric silencing. In C. glabrata there are three Sir proteins (Sir2, Sir3 and Sir4) that are essential for subtelomeric silencing. Among a collection of 79 clinical isolates, some display a hyperadherent phenotype to epithelial cells compared to our standard laboratory strain, BG14. These isolates also express several subtelomeric EPA genes simultaneously. We cloned the SIR2, SIR3 and SIR4 genes from the hyperadherent isolates and from the BG14 and the sequenced strain CBS138 in a replicative vector to complement null mutants in each of these genes in the BG14 background. All the SIR2 and SIR4 alleles tested from selected hyper-adherent isolates were functional and efficient to silence a URA3 reporter gene inserted in a subtelomeric region. The SIR3 alleles from these isolates were also functional, except the allele from isolate MC2 (sir3-MC2), which was not functional to silence the reporter and did not complement the hyperadherent phenotype of the BG14 sir3Δ. Consistently, sir3-MC2 allele is recessive to the SIR3 allele from BG14. Sir3 and Sir4 alleles from the hyperadherent isolates contain several polymorphisms and two of them are present in all the hyperadherent isolates analyzed. Instead, the Sir3 and Sir4 alleles from the BG14 and another non-adherent isolate do not display these polymorphisms and are identical to each other. The particular combination of polymorphisms in sir3-MC2 and in SIR4-MC2 could explain in part the hyperadherent phenotype displayed by this isolate. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. Are electronic health records ready for genomic medicine?

    PubMed

    Scheuner, Maren T; de Vries, Han; Kim, Benjamin; Meili, Robin C; Olmstead, Sarah H; Teleki, Stephanie

    2009-07-01

    The goal of this project was to assess genetic/genomic content in electronic health records. Semistructured interviews were conducted with key informants. Questions addressed documentation, organization, display, decision support and security of family history and genetic test information, and challenges and opportunities relating to integrating genetic/genomics content in electronic health records. There were 56 participants: 10 electronic health record specialists, 18 primary care clinicians, 16 medical geneticists, and 12 genetic counselors. Few clinicians felt their electronic record met their current genetic/genomic medicine needs. Barriers to integration were mostly related to problems with family history data collection, documentation, and organization. Lack of demand for genetics content and privacy concerns were also mentioned as challenges. Data elements and functionality requirements that clinicians see include: pedigree drawing; clinical decision support for familial risk assessment and genetic testing indications; a patient portal for patient-entered data; and standards for data elements, terminology, structure, interoperability, and clinical decision support rules. Although most said that there is little impact of genetics/genomics on electronic records today, many stated genetics/genomics would be a driver of content in the next 5-10 years. Electronic health records have the potential to enable clinical integration of genetic/genomic medicine and improve delivery of personalized health care; however, structured and standardized data elements and functionality requirements are needed.

  3. LOGISTIC FUNCTION PROFILE FIT: A least-squares program for fitting interface profiles to an extended logistic function

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kirchhoff, William H.

    2012-09-15

    The extended logistic function provides a physically reasonable description of interfaces such as depth profiles or line scans of surface topological or compositional features. It describes these interfaces with the minimum number of parameters, namely, position, width, and asymmetry. Logistic Function Profile Fit (LFPF) is a robust, least-squares fitting program in which the nonlinear extended logistic function is linearized by a Taylor series expansion (equivalent to a Newton-Raphson approach) with no apparent introduction of bias in the analysis. The program provides reliable confidence limits for the parameters when systematic errors are minimal and provides a display of the residuals frommore » the fit for the detection of systematic errors. The program will aid researchers in applying ASTM E1636-10, 'Standard practice for analytically describing sputter-depth-profile and linescan-profile data by an extended logistic function,' and may also prove useful in applying ISO 18516: 2006, 'Surface chemical analysis-Auger electron spectroscopy and x-ray photoelectron spectroscopy-determination of lateral resolution.' Examples are given of LFPF fits to a secondary ion mass spectrometry depth profile, an Auger surface line scan, and synthetic data generated to exhibit known systematic errors for examining the significance of such errors to the extrapolation of partial profiles.« less

  4. Evaluation of inorganic and organic light-emitting diode displays for signage application

    NASA Astrophysics Data System (ADS)

    Sharma, Pratibha; Kwok, Harry

    2006-08-01

    High-brightness, inorganic light-emitting diodes (LEDs) have been successfully utilized for edge-lighting of large displays for signage. Further interest in solid-state lighting technology has been fueled with the emergence of small molecule and polymer-based organic light-emitting diodes (OLEDs). In this paper, edgelit inorganic LED-based displays and state-of-the-art OLED-based displays are evaluated on the basis of electrical and photometric measurements. The reference size for a signage system is assumed to be 600 mm x 600mm based on the industrial usage. With the availability of high power light-emitting diodes, it is possible to develop edgelit signage systems of the standard size. These displays possess an efficacy of 18 lm/W. Although, these displays are environmentally friendly and efficient, they suffer from some inherent limitations. Homogeneity of displays, which is a prime requirement for illuminated signs, is not accomplished. A standard deviation of 3.12 lux is observed between the illuminance values on the surface of the display. In order to distribute light effectively, reflective gratings are employed. Reflective gratings aid in reducing the problem but fail to eliminate it. In addition, the overall cost of signage is increased by 50% with the use of these additional components. This problem can be overcome by the use of a distributed source of light. Hence, the organic-LEDs are considered as a possible contender. In this paper, we experimentally determine the feasibility of using OLEDs for signage applications and compare their performance with inorganic LEDs. Passive matrix, small-molecule based, commercially available OLEDs is used. Design techniques for implementation of displays using organic LEDs are also discussed. It is determined that tiled displays based on organic LEDs possess better uniformity than the inorganic LED-based displays. However, the currently available OLEDs have lower light-conversion efficiency and higher costs than the conventional, inorganic LEDs. But, signage panels based on OLEDs can be made cheaper by avoiding the use of acrylic sheet and reflective gratings. Moreover, the distributed light output and light weight of OLEDs and the potential to be built inexpensively on flexible substrates can make OLEDs more beneficial for future signage applications than the inorganic LEDs.

  5. Disintegration of Sensorimotor Brain Networks in Schizophrenia.

    PubMed

    Kaufmann, Tobias; Skåtun, Kristina C; Alnæs, Dag; Doan, Nhat Trung; Duff, Eugene P; Tønnesen, Siren; Roussos, Evangelos; Ueland, Torill; Aminoff, Sofie R; Lagerberg, Trine V; Agartz, Ingrid; Melle, Ingrid S; Smith, Stephen M; Andreassen, Ole A; Westlye, Lars T

    2015-11-01

    Schizophrenia is a severe mental disorder associated with derogated function across various domains, including perception, language, motor, emotional, and social behavior. Due to its complex symptomatology, schizophrenia is often regarded a disorder of cognitive processes. Yet due to the frequent involvement of sensory and perceptual symptoms, it has been hypothesized that functional disintegration between sensory and cognitive processes mediates the heterogeneous and comprehensive schizophrenia symptomatology. Here, using resting-state functional magnetic resonance imaging in 71 patients and 196 healthy controls, we characterized the standard deviation in BOLD (blood-oxygen-level-dependent) signal amplitude and the functional connectivity across a range of functional brain networks. We investigated connectivity on the edge and node level using network modeling based on independent component analysis and utilized the brain network features in cross-validated classification procedures. Both amplitude and connectivity were significantly altered in patients, largely involving sensory networks. Reduced standard deviation in amplitude was observed in a range of visual, sensorimotor, and auditory nodes in patients. The strongest differences in connectivity implicated within-sensorimotor and sensorimotor-thalamic connections. Furthermore, sensory nodes displayed widespread alterations in the connectivity with higher-order nodes. We demonstrated robustness of effects across subjects by significantly classifying diagnostic group on the individual level based on cross-validated multivariate connectivity features. Taken together, the findings support the hypothesis of disintegrated sensory and cognitive processes in schizophrenia, and the foci of effects emphasize that targeting the sensory and perceptual domains may be key to enhance our understanding of schizophrenia pathophysiology. © The Author 2015. Published by Oxford University Press on behalf of the Maryland Psychiatric Research Center. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  6. An Analysis of Functional Communication Training as an Empirically Supported Treatment for Problem Behavior Displayed by Individuals with Intellectual Disabilities

    ERIC Educational Resources Information Center

    Kurtz, Patricia F.; Boelter, Eric W.; Jarmolowicz, David P.; Chin, Michelle D.; Hagopian, Louis P.

    2011-01-01

    This paper examines the literature on the use of functional communication training (FCT) as a treatment for problem behavior displayed by individuals with intellectual disabilities (ID). Criteria for empirically supported treatments developed by Divisions 12 and 16 of the American Psychological Association (Kratochwill & Stoiber, 2002; Task Force,…

  7. Effects of heat stress and probiotic supplementation on protein functionality and oxidative stability of ground chicken leg meat during display storage

    USDA-ARS?s Scientific Manuscript database

    The objective of this study was to evaluate effects of heat stress and probiotic supplementation on protein functionality and oxidative stability of ground chicken leg meat during display storage. Two hundred and forty 1-day-old male chicks (5 bird per pen) were randomly subjected to four treatments...

  8. 1968 Listing of Swimming Pool Equipment.

    ERIC Educational Resources Information Center

    National Sanitation Foundation, Ann Arbor, MI. Testing Lab.

    An up-to-date listing of swimming pool equipment including--(1) companies authorized to display the National Sanitation Foundation seal of approval, (2) equipment listed as meeting NSF swimming pool equipment standards relating to diatomite type filters, (3) equipment listed as meeting NSF swimming pool equipment standard relating to sand type…

  9. Fiber-channel audio video standard for military and commercial aircraft product lines

    NASA Astrophysics Data System (ADS)

    Keller, Jack E.

    2002-08-01

    Fibre channel is an emerging high-speed digital network technology that combines to make inroads into the avionics arena. The suitability of fibre channel for such applications is largely due to its flexibility in these key areas: Network topologies can be configured in point-to-point, arbitrated loop or switched fabric connections. The physical layer supports either copper or fiber optic implementations with a Bit Error Rate of less than 10-12. Multiple Classes of Service are available. Multiple Upper Level Protocols are supported. Multiple high speed data rates offer open ended growth paths providing speed negotiation within a single network. Current speeds supported by commercially available hardware are 1 and 2 Gbps providing effective data rates of 100 and 200 MBps respectively. Such networks lend themselves well to the transport of digital video and audio data. This paper summarizes an ANSI standard currently in the final approval cycle of the InterNational Committee for Information Technology Standardization (INCITS). This standard defines a flexible mechanism whereby digital video, audio and ancillary data are systematically packaged for transport over a fibre channel network. The basic mechanism, called a container, houses audio and video content functionally grouped as elements of the container called objects. Featured in this paper is a specific container mapping called Simple Parametric Digital Video (SPDV) developed particularly to address digital video in avionics systems. SPDV provides pixel-based video with associated ancillary data typically sourced by various sensors to be processed and/or distributed in the cockpit for presentation via high-resolution displays. Also highlighted in this paper is a streamlined Upper Level Protocol (ULP) called Frame Header Control Procedure (FHCP) targeted for avionics systems where the functionality of a more complex ULP is not required.

  10. Finding Your Way out of the Forest without a Trail of Bread Crumbs: Development and Evaluation of Two Novel Displays of Forest Plots

    ERIC Educational Resources Information Center

    Schild, Anne H. E.; Voracek, Martin

    2015-01-01

    Research has shown that forest plots are a gold standard in the visualization of meta-analytic results. However, research on the general interpretation of forest plots and the role of researchers' meta-analysis experience and field of study is still unavailable. Additionally, the traditional display of effect sizes, confidence intervals, and…

  11. 3D Displays for Battle Management

    DTIC Science & Technology

    1990-04-01

    cinematography industry, were found to be inadequate for providing comfortable stereoscopic out-the-window terrain scenes, when viewed from a 19-inch...JStereoscoDic Projection GeomietrvL Existing stereoscopic drawing / fechniques, which have roots in t cinematography industry, were , found to be...categories. By calibrating our CRT monitors to known color standards, we are able to produce the measured hues on the display screen. 5.2 COMPLEXITY

  12. What Makes a Matrix so Effective? An Empirical Test of the Relative Benefits of Signaling, Extraction, and Localization

    ERIC Educational Resources Information Center

    Kauffman, Douglas F.; Kiewra, Kenneth A.

    2010-01-01

    What type of display helps students learn the most and why? This study investigated how displays differing in terms of signaling, extraction, and localization impact learning. In Experiment 1, 72 students were assigned randomly to one cell of a 4 x 2 design. Students studied a standard text, a text with key ideas extracted, an outline that…

  13. Novel flight instrument display to minimize the risk of spatial disorientation

    NASA Astrophysics Data System (ADS)

    Braithwaite, Malcolm G.; Durnford, Simon J.

    1997-06-01

    This novel flight instrument display presents information to the pilot in a simple and easily comprehensible format by integrating the five orientational flight parameters. It allows the pilot to select specific orientation parameters and then follow a simple tracking task which ensures that these parameters are maintained or, if necessary, recovered. The pilot can at any time check any parameter he wishes, but is free from the requirement to continually sample and combine information from the traditional instruments to maintain stable flight. Cognitive workload to maintain orientation is thus reduced. Our assessment of the display in a UH-60 helicopter simulator showed that the novel display makes recovery from unusual aircraft attitudes and instrument flying easier than when using the standard instrument panel.

  14. [Risk analysis and assessment of occupational hazard fromindiumand its compounds in manufacture of liquid crystal display panel].

    PubMed

    Qiu, Haili; Zhou, Wei; Li, Zhimin; Tian, Dongchao; Weng, Shaofan; He, Juntao

    2015-08-01

    To understand the exposed positions and levels of indium and its compounds in manufacture of liquid crystal displays, and to evaluate the degree of occupational hazard from indium and its compounds. On-site investigation of occupational health, occupational hazard monitoring, and occupational health examination were used to evaluate the degree of occupational hazard from indium and its compounds in three manufacturers of liquid crystal display panel in Shenzhen, Guangdong, China. The time-weighted average (TWA) and short-term exposure limit (STEL) concentrations of indium and its compounds to which sputtering machine operating positions were exposed were less than 0.002~0.004 mg/m³ and 0.006~0.007 mg/m³, respectively, both of which complied with the National Hygienic Standard (PC-TWA = 0.1 mg/m³; PC-STEL = 0.3 mg/m³); the TWA and STEL concentrations of indium and its compounds to which grinding positions were exposed were 0.114~2.98 mg/m³ and 0.31~10.02 mg/m³, respectively, both of which exceeded the National Hygienic Standard with the highest concentration 33-fold higher than the standard. No significant health damages were found in exposed workers according to the results of occupational health examination. The grinding positions are the key to the control of occupational hazard from indium and its compounds in manufacture of liquid crystal display panel. The workers should be equipped with the anti-particulate full-face respirator, which is an effective way to prevent occupational hazard from indium and its compounds.

  15. Lapin Data Interchange Among Database, Analysis and Display Programs Using XML-Based Text Files

    NASA Technical Reports Server (NTRS)

    2005-01-01

    The purpose of grant NCC3-966 was to investigate and evaluate the interchange of application-specific data among multiple programs each carrying out part of the analysis and design task. This has been carried out previously by creating a custom program to read data produced by one application and then write that data to a file whose format is specific to the second application that needs all or part of that data. In this investigation, data of interest is described using the XML markup language that allows the data to be stored in a text-string. Software to transform output data of a task into an XML-string and software to read an XML string and extract all or a portion of the data needed for another application is used to link two independent applications together as part of an overall design effort. This approach was initially used with a standard analysis program, Lapin, along with standard applications a standard spreadsheet program, a relational database program, and a conventional dialog and display program to demonstrate the successful sharing of data among independent programs. Most of the effort beyond that demonstration has been concentrated on the inclusion of more complex display programs. Specifically, a custom-written windowing program organized around dialogs to control the interactions have been combined with an independent CAD program (Open Cascade) that supports sophisticated display of CAD elements such as lines, spline curves, and surfaces and turbine-blade data produced by an independent blade design program (UD0300).

  16. Cybersecurity for Connected Diabetes Devices

    PubMed Central

    Klonoff, David C.

    2015-01-01

    Diabetes devices are increasingly connected wirelessly to each other and to data-displaying reader devices. Threats to the accurate flow of information and commands may compromise the function of these devices and put their users at risk of health complications. Sound cybersecurity of connected diabetes devices is necessary to maintain confidentiality, integrity, and availability of the data and commands. Diabetes devices can be hacked by unauthorized agents and also by patients themselves to extract data that are not automatically provided by product software. Unauthorized access to connected diabetes devices has been simulated and could happen in reality. A cybersecurity standard designed specifically for connected diabetes devices will improve the safety of these products and increase confidence of users that the products will be secure. PMID:25883162

  17. TRANSFORM - TRANsient Simulation Framework of Reconfigurable Models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Greenwood, Michael S; Cetiner, Mustafa S; Fugate, David L

    Existing development tools for early stage design and scoping of energy systems are often time consuming to use, proprietary, and do not contain the necessary function to model complete systems (i.e., controls, primary, and secondary systems) in a common platform. The Modelica programming language based TRANSFORM tool (1) provides a standardized, common simulation environment for early design of energy systems (i.e., power plants), (2) provides a library of baseline component modules to be assembled into full plant models using available geometry, design, and thermal-hydraulic data, (3) defines modeling conventions for interconnecting component models, and (4) establishes user interfaces and supportmore » tools to facilitate simulation development (i.e., configuration and parameterization), execution, and results display and capture.« less

  18. Cybersecurity for Connected Diabetes Devices.

    PubMed

    Klonoff, David C

    2015-04-16

    Diabetes devices are increasingly connected wirelessly to each other and to data-displaying reader devices. Threats to the accurate flow of information and commands may compromise the function of these devices and put their users at risk of health complications. Sound cybersecurity of connected diabetes devices is necessary to maintain confidentiality, integrity, and availability of the data and commands. Diabetes devices can be hacked by unauthorized agents and also by patients themselves to extract data that are not automatically provided by product software. Unauthorized access to connected diabetes devices has been simulated and could happen in reality. A cybersecurity standard designed specifically for connected diabetes devices will improve the safety of these products and increase confidence of users that the products will be secure. © 2015 Diabetes Technology Society.

  19. TAILSIM Users Guide

    NASA Technical Reports Server (NTRS)

    Hiltner, Dale W.

    2000-01-01

    The TAILSIM program uses a 4th order Runge-Kutta method to integrate the standard aircraft equations-of-motion (EOM). The EOM determine three translational and three rotational accelerations about the aircraft's body axis reference system. The forces and moments that drive the EOM are determined from aerodynamic coefficients, dynamic derivatives, and control inputs. Values for these terms are determined from linear interpolation of tables that are a function of parameters such as angle-of-attack and surface deflections. Buildup equations combine these terms and dimensionalize them to generate the driving total forces and moments. Features that make TAILSIM applicable to studies of tailplane stall include modeling of the reversible control System, modeling of the pilot performing a load factor and/or airspeed command task, and modeling of vertical gusts. The reversible control system dynamics can be described as two hinged masses connected by a spring. resulting in a fifth order system. The pilot model is a standard form of lead-lag with a time delay applied to an integrated pitch rate and/or airspeed error feedback. The time delay is implemented by a Pade approximation, while the commanded pitch rate is determined by a commanded load factor. Vertical gust inputs include a single 1-cosine gust and a continuous NASA Dryden gust model. These dynamic models. coupled with the use of a nonlinear database, allow the tailplane stall characteristics, elevator response, and resulting aircraft response, to be modeled. A useful output capability of the TAILSIM program is the ability to display multiple post-run plot pages to allow a quick assessment of the time history response. There are 16 plot pages currently available to the user. Each plot page displays 9 parameters. Each parameter can also be displayed individually. on a one plot-per-page format. For a more refined display of the results the program can also create files of tabulated data. which can then be used by other plotting programs. The TAILSIM program was written straightforwardly assuming the user would want to change the database tables, the buildup equations, the output parameters. and the pilot model parameters. A separate database file and input file are automatically read in by the program. The use of an include file to set up all common blocks facilitates easy changing of parameter names and array sizes.

  20. NASA UAS Integration into the NAS Project Detect and Avoid Display Evaluations

    NASA Technical Reports Server (NTRS)

    Shively, Jay

    2016-01-01

    As part of the Air Force - NASA Bi-Annual Research Council Meeting, slides will be presented on phase 1 Detect and Avoid (DAA) display evaluations. A series of iterative human-in-the-loops (HITL) experiments were conducted with different display configurations to objectively measure pilot performance on maintaining well clear. To date, four simulations and two mini-HITLs have been conducted. Data from these experiments have been incorporated into a revised alerting structure and included in the RTCA SC 228 Phase 1 Minimum Operational Performance Standards (MOPS) proposal. Plans for phase 2 are briefly discussed.

  1. A spatio-temporal model of the human observer for use in display design

    NASA Astrophysics Data System (ADS)

    Bosman, Dick

    1989-08-01

    A "quick look" visual model, a kind of standard observer in software, is being developed to estimate the appearance of new display designs before prototypes are built. It operates on images also stored in software. It is assumed that the majority of display design flaws and technology artefacts can be identified in representations of early visual processing, and insight obtained into very local to global (supra-threshold) brightness distributions. Cognitive aspects are not considered because it seems that poor acceptance of technology and design is only weakly coupled to image content.

  2. Web-based application for inverting one-dimensional magnetotelluric data using Python

    NASA Astrophysics Data System (ADS)

    Suryanto, Wiwit; Irnaka, Theodosius Marwan

    2016-11-01

    One-dimensional modeling of magnetotelluric (MT) data has been performed using an online application on a web-based virtual private server. The application was developed with the Python language using the Django framework with HTML and CSS components. The input data, including the apparent resistivity and phase as a function of period or frequency with standard deviation, can be entered through an interactive web page that can be freely accessed at https://komputasi.geofisika.ugm.ac.id. The subsurface models, represented by resistivity as a function of depth, are iteratively improved by changing the model parameters, such as the resistivity and the layer depth, based on the observed apparent resistivity and phase data. The output of the application displayed on the screen presents resistivity as a function of depth and includes the RMS error for each iteration. Synthetic and real data were used in comparative tests of the application's performance, and it is shown that the application developed accurate subsurface resistivity models. Hence, this application can be used for practical one-dimensional modeling of MT data.

  3. A new "Logicle" display method avoids deceptive effects of logarithmic scaling for low signals and compensated data.

    PubMed

    Parks, David R; Roederer, Mario; Moore, Wayne A

    2006-06-01

    In immunofluorescence measurements and most other flow cytometry applications, fluorescence signals of interest can range down to essentially zero. After fluorescence compensation, some cell populations will have low means and include events with negative data values. Logarithmic presentation has been very useful in providing informative displays of wide-ranging flow cytometry data, but it fails to adequately display cell populations with low means and high variances and, in particular, offers no way to include negative data values. This has led to a great deal of difficulty in interpreting and understanding flow cytometry data, has often resulted in incorrect delineation of cell populations, and has led many people to question the correctness of compensation computations that were, in fact, correct. We identified a set of criteria for creating data visualization methods that accommodate the scaling difficulties presented by flow cytometry data. On the basis of these, we developed a new data visualization method that provides important advantages over linear or logarithmic scaling for display of flow cytometry data, a scaling we refer to as "Logicle" scaling. Logicle functions represent a particular generalization of the hyperbolic sine function with one more adjustable parameter than linear or logarithmic functions. Finally, we developed methods for objectively and automatically selecting an appropriate value for this parameter. The Logicle display method provides more complete, appropriate, and readily interpretable representations of data that includes populations with low-to-zero means, including distributions resulting from fluorescence compensation procedures, than can be produced using either logarithmic or linear displays. The method includes a specific algorithm for evaluating actual data distributions and deriving parameters of the Logicle scaling function appropriate for optimal display of that data. It is critical to note that Logicle visualization does not change the data values or the descriptive statistics computed from them. Copyright 2006 International Society for Analytical Cytology.

  4. Fetal heart rate monitoring device using condenser microphone sensor: Validation and comparison to standard devices.

    PubMed

    Ahmad, Husna Azyan Binti; El-Badawy, Ismail M; Singh, Om Prakash; Hisham, Rozana Binti; Malarvili, M B

    2018-04-27

    Fetal heart rate (FHR) monitoring device is highly demanded to assess the fetus health condition in home environments. Conventional standard devices such as ultrasonography and cardiotocography are expensive, bulky and uncomfortable and consequently not suitable for long-term monitoring. Herein, we report a device that can be used to measure fetal heart rate in clinical and home environments. The proposed device measures and displays the FHR on a screen liquid crystal display (LCD). The device consists of hardware that comprises condenser microphone sensor, signal conditioning, microcontroller and LCD, and software that involves the algorithm used for processing the conditioned fetal heart signal prior to FHR display. The device's performance is validated based on analysis of variance (ANOVA) test. FHR data was recorded from 22 pregnant women during the 17th to 37th week of gestation using the developed device and two standard devices; AngelSounds and Electronic Stethoscope. The results show that F-value (1.5) is less than F, (3.1) and p-value (p> 0.05). Accordingly, there is no significant difference between the mean readings of the developed and existing devices. Hence, the developed device can be used for monitoring FHR in clinical and home environments.

  5. Display Considerations For Intravascular Ultrasonic Imaging

    NASA Astrophysics Data System (ADS)

    Gessert, James M.; Krinke, Charlie; Mallery, John A.; Zalesky, Paul J.

    1989-08-01

    A display has been developed for intravascular ultrasonic imaging. Design of this display has a primary goal of providing guidance information for therapeutic interventions such as balloons, lasers, and atherectomy devices. Design considerations include catheter configuration, anatomy, acoustic properties of normal and diseased tissue, catheterization laboratory and operating room environment, acoustic and electrical safety, acoustic data sampling issues, and logistical support such as image measurement, storage and retrieval. Intravascular imaging is in an early stage of development so design flexibility and expandability are very important. The display which has been developed is capable of acquisition and display of grey scale images at rates varying from static B-scans to 30 frames per second. It stores images in a 640 X 480 X 8 bit format and is capable of black and white as well as color display in multiplevideo formats. The design is based on the industry standard PC-AT architecture and consists of two AT style circuit cards, one for high speed sampling and the other for scan conversion, graphics and video generation.

  6. Human Cells Display Reduced Apoptotic Function Relative to Chimpanzee Cells

    PubMed Central

    McDonald, John F.

    2012-01-01

    Previously published gene expression analyses suggested that apoptotic function may be reduced in humans relative to chimpanzees and led to the hypothesis that this difference may contribute to the relatively larger size of the human brain and the increased propensity of humans to develop cancer. In this study, we sought to further test the hypothesis that humans maintain a reduced apoptotic function relative to chimpanzees by conducting a series of apoptotic function assays on human, chimpanzee and macaque primary fibroblastic cells. Human cells consistently displayed significantly reduced apoptotic function relative to the chimpanzee and macaque cells. These results are consistent with earlier findings indicating that apoptotic function is reduced in humans relative to chimpanzees. PMID:23029431

  7. Simulating multiprimary LCDs on standard tri-stimulus LC displays

    NASA Astrophysics Data System (ADS)

    Lebowsky, Fritz; Vonneilich, Katrin; Bonse, Thomas

    2008-01-01

    Large-scale, direct view TV screens, in particular those based on liquid crystal technology, are beginning to use subpixel structures with more than three subpixels to implement a multi-primary display with up to six primaries. Since their input color space is likely to remain tri-stimulus RGB we first focus on some fundamental constraints. Among them, we elaborate simplified gamut mapping architectures as well as color filter geometry, transparency, and chromaticity coordinates in color space. Based on a 'display centric' RGB color space tetrahedrization combined with linear interpolation we describe a simulation framework which enables optimization for up to 7 primaries. We evaluated the performance through mapping the multi-primary design back onto a RGB LC display gamut without building a prototype multi-primary display. As long as we kept the RGB equivalent output signal within the display gamut we could analyze all desirable multi-primary configurations with regard to colorimetric variance and visually perceived quality. Not only does our simulation tool enable us to verify a novel concept it also demonstrates how carefully one needs to design a multiprimary display for LCD TV applications.

  8. Research into display sharing techniques for distributed computing environments

    NASA Technical Reports Server (NTRS)

    Hugg, Steven B.; Fitzgerald, Paul F., Jr.; Rosson, Nina Y.; Johns, Stephen R.

    1990-01-01

    The X-based Display Sharing solution for distributed computing environments is described. The Display Sharing prototype includes the base functionality for telecast and display copy requirements. Since the prototype implementation is modular and the system design provided flexibility for the Mission Control Center Upgrade (MCCU) operational consideration, the prototype implementation can be the baseline for a production Display Sharing implementation. To facilitate the process the following discussions are presented: Theory of operation; System of architecture; Using the prototype; Software description; Research tools; Prototype evaluation; and Outstanding issues. The prototype is based on the concept of a dedicated central host performing the majority of the Display Sharing processing, allowing minimal impact on each individual workstation. Each workstation participating in Display Sharing hosts programs to facilitate the user's access to Display Sharing as host machine.

  9. A cellular star atlas: using astrocytes from human pluripotent stem cells for disease studies

    PubMed Central

    Krencik, Robert; Ullian, Erik M.

    2013-01-01

    What roles do astrocytes play in human disease?This question remains unanswered for nearly every human neurological disorder. Yet, because of their abundance and complexity astrocytes can impact neurological function in many ways. The differentiation of human pluripotent stem cells (hPSCs) into neuronal and glial subtypes, including astrocytes, is becoming routine, thus their use as tools for modeling neurodevelopment and disease will provide one important approach to answer this question. When designing experiments, careful consideration must be given to choosing paradigms for differentiation, maturation, and functional analysis of these temporally asynchronous cellular populations in culture. In the case of astrocytes, they display heterogeneous characteristics depending upon species of origin, brain region, developmental stage, environmental factors, and disease states, all of which may render experimental results highly variable. In this review, challenges and future directions are discussed for using hPSC-derived astroglial progenitors and mature astrocytes for neurodevelopmental studies with a focus on exploring human astrocyte effects upon neuronal function. As new technologies emerge to measure the functions of astrocytes in vitro and in vivo, there is also a need for a standardized source of human astrocytes that are most relevant to the diseases of interest. PMID:23503583

  10. Ff-nano, short functionalized nanorods derived from Ff (f1, fd, or M13) filamentous bacteriophage

    PubMed Central

    Sattar, Sadia; Bennett, Nicholas J.; Wen, Wesley X.; Guthrie, Jenness M.; Blackwell, Len F.; Conway, James F.; Rakonjac, Jasna

    2015-01-01

    F-specific filamentous phage of Escherichia coli (Ff: f1, M13, or fd) are long thin filaments (860 nm × 6 nm). They have been a major workhorse in display technologies and bionanotechnology; however, some applications are limited by the high length-to-diameter ratio of Ff. Furthermore, use of functionalized Ff outside of laboratory containment is in part hampered by the fact that they are genetically modified viruses. We have now developed a system for production and purification of very short functionalized Ff-phage-derived nanorods, named Ff-nano, that are only 50 nm in length. In contrast to standard Ff-derived vectors that replicate in E. coli and contain antibiotic-resistance genes, Ff-nano are protein-DNA complexes that cannot replicate on their own and do not contain any coding sequences. These nanorods show an increased resistance to heating at 70∘C in 1% SDS in comparison to the full-length Ff phage of the same coat composition. We demonstrate that functionalized Ff-nano particles are suitable for application as detection particles in sensitive and quantitative “dipstick” lateral flow diagnostic assay for human plasma fibronectin. PMID:25941520

  11. Ff-nano, short functionalized nanorods derived from Ff (f1, fd, or M13) filamentous bacteriophage.

    PubMed

    Sattar, Sadia; Bennett, Nicholas J; Wen, Wesley X; Guthrie, Jenness M; Blackwell, Len F; Conway, James F; Rakonjac, Jasna

    2015-01-01

    F-specific filamentous phage of Escherichia coli (Ff: f1, M13, or fd) are long thin filaments (860 nm × 6 nm). They have been a major workhorse in display technologies and bionanotechnology; however, some applications are limited by the high length-to-diameter ratio of Ff. Furthermore, use of functionalized Ff outside of laboratory containment is in part hampered by the fact that they are genetically modified viruses. We have now developed a system for production and purification of very short functionalized Ff-phage-derived nanorods, named Ff-nano, that are only 50 nm in length. In contrast to standard Ff-derived vectors that replicate in E. coli and contain antibiotic-resistance genes, Ff-nano are protein-DNA complexes that cannot replicate on their own and do not contain any coding sequences. These nanorods show an increased resistance to heating at 70(∘)C in 1% SDS in comparison to the full-length Ff phage of the same coat composition. We demonstrate that functionalized Ff-nano particles are suitable for application as detection particles in sensitive and quantitative "dipstick" lateral flow diagnostic assay for human plasma fibronectin.

  12. Vitamin D and muscle function in the elderly: the elixir of youth?

    PubMed

    Girgis, Christian M

    2014-11-01

    Circumstantial evidence suggests that vitamin D deficiency may contribute to age-related changes in skeletal muscle. This review discusses recent clinical trials examining effects of vitamin D on muscle function in the elderly, and poses the important question: can vitamin D reverse muscle ageing? Observational studies report an association between vitamin D and muscle atrophy/weakness in elderly subjects. Interventional studies suggest that frail, elderly subjects may benefit from vitamin D supplementation by displaying reduced falls, improved muscle function and increased muscle fibre size. However, meta-analyses do not report convincing effects of vitamin D in the elderly. This may be because of multiple factors including lack of standardized endpoints for muscle function, variable study design and different doses of vitamin D supplementation amongst these studies. The evidence base is therefore inconsistent. Vitamin D deficiency may exacerbate ageing of skeletal muscle. However, current evidence that vitamin D supplementation reverses age-related muscle dysfunction is equivocal and does not justify stringent vitamin D targets in the elderly. Until these issues are clarified, the safest option is to aim for conservative vitamin D targets that are sufficient for normal calcium homeostasis.

  13. Smile line assessment comparing quantitative measurement and visual estimation.

    PubMed

    Van der Geld, Pieter; Oosterveld, Paul; Schols, Jan; Kuijpers-Jagtman, Anne Marie

    2011-02-01

    Esthetic analysis of dynamic functions such as spontaneous smiling is feasible by using digital videography and computer measurement for lip line height and tooth display. Because quantitative measurements are time-consuming, digital videography and semiquantitative (visual) estimation according to a standard categorization are more practical for regular diagnostics. Our objective in this study was to compare 2 semiquantitative methods with quantitative measurements for reliability and agreement. The faces of 122 male participants were individually registered by using digital videography. Spontaneous and posed smiles were captured. On the records, maxillary lip line heights and tooth display were digitally measured on each tooth and also visually estimated according to 3-grade and 4-grade scales. Two raters were involved. An error analysis was performed. Reliability was established with kappa statistics. Interexaminer and intraexaminer reliability values were high, with median kappa values from 0.79 to 0.88. Agreement of the 3-grade scale estimation with quantitative measurement showed higher median kappa values (0.76) than the 4-grade scale estimation (0.66). Differentiating high and gummy smile lines (4-grade scale) resulted in greater inaccuracies. The estimation of a high, average, or low smile line for each tooth showed high reliability close to quantitative measurements. Smile line analysis can be performed reliably with a 3-grade scale (visual) semiquantitative estimation. For a more comprehensive diagnosis, additional measuring is proposed, especially in patients with disproportional gingival display. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  14. Interactive metagenomic visualization in a Web browser.

    PubMed

    Ondov, Brian D; Bergman, Nicholas H; Phillippy, Adam M

    2011-09-30

    A critical output of metagenomic studies is the estimation of abundances of taxonomical or functional groups. The inherent uncertainty in assignments to these groups makes it important to consider both their hierarchical contexts and their prediction confidence. The current tools for visualizing metagenomic data, however, omit or distort quantitative hierarchical relationships and lack the facility for displaying secondary variables. Here we present Krona, a new visualization tool that allows intuitive exploration of relative abundances and confidences within the complex hierarchies of metagenomic classifications. Krona combines a variant of radial, space-filling displays with parametric coloring and interactive polar-coordinate zooming. The HTML5 and JavaScript implementation enables fully interactive charts that can be explored with any modern Web browser, without the need for installed software or plug-ins. This Web-based architecture also allows each chart to be an independent document, making them easy to share via e-mail or post to a standard Web server. To illustrate Krona's utility, we describe its application to various metagenomic data sets and its compatibility with popular metagenomic analysis tools. Krona is both a powerful metagenomic visualization tool and a demonstration of the potential of HTML5 for highly accessible bioinformatic visualizations. Its rich and interactive displays facilitate more informed interpretations of metagenomic analyses, while its implementation as a browser-based application makes it extremely portable and easily adopted into existing analysis packages. Both the Krona rendering code and conversion tools are freely available under a BSD open-source license, and available from: http://krona.sourceforge.net.

  15. Role of HIS/RIS DICOM interfaces in the integration of imaging into the Department of Veterans Affairs healthcare enterprise

    NASA Astrophysics Data System (ADS)

    Kuzmak, Peter M.; Dayhoff, Ruth E.

    1998-07-01

    The U.S. Department of Veterans Affairs is integrating imaging into the healthcare enterprise using the Digital Imaging and Communication in Medicine (DICOM) standard protocols. Image management is directly integrated into the VistA Hospital Information System (HIS) software and clinical database. Radiology images are acquired via DICOM, and are stored directly in the HIS database. Images can be displayed on low- cost clinician's workstations throughout the medical center. High-resolution diagnostic quality multi-monitor VistA workstations with specialized viewing software can be used for reading radiology images. DICOM has played critical roles in the ability to integrate imaging functionality into the Healthcare Enterprise. Because of its openness, it allows the integration of system components from commercial and non- commercial sources to work together to provide functional cost-effective solutions (see Figure 1). Two approaches are used to acquire and handle images within the radiology department. At some VA Medical Centers, DICOM is used to interface a commercial Picture Archiving and Communications System (PACS) to the VistA HIS. At other medical centers, DICOM is used to interface the image producing modalities directly to the image acquisition and display capabilities of VistA itself. Both of these approaches use a small set of DICOM services that has been implemented by VistA to allow patient and study text data to be transmitted to image producing modalities and the commercial PACS, and to enable images and study data to be transferred back.

  16. Wireless Instantaneous Neurotransmitter Concentration Sensing System (WINCS) for intraoperative neurochemical monitoring.

    PubMed

    Kimble, Christopher J; Johnson, David M; Winter, Bruce A; Whitlock, Sidney V; Kressin, Kenneth R; Horne, April E; Robinson, Justin C; Bledsoe, Jonathan M; Tye, Susannah J; Chang, Su-Youne; Agnesi, Filippo; Griessenauer, Christoph J; Covey, Daniel; Shon, Young-Min; Bennet, Kevin E; Garris, Paul A; Lee, Kendall H

    2009-01-01

    The Wireless Instantaneous Neurotransmitter Concentration Sensing System (WINCS) measures extracellular neurotransmitter concentration in vivo and displays the data graphically in nearly real time. WINCS implements two electroanalytical methods, fast-scan cyclic voltammetry (FSCV) and fixed-potential amperometry (FPA), to measure neurotransmitter concentrations at an electrochemical sensor, typically a carbon-fiber microelectrode. WINCS comprises a battery-powered patient module and a custom software application (WINCSware) running on a nearby personal computer. The patient module impresses upon the electrochemical sensor either a constant potential (for FPA) or a time-varying waveform (for FSCV). A transimpedance amplifier converts the resulting current to a signal that is digitized and transmitted to the base station via a Bluetooth radio link. WINCSware controls the operational parameters for FPA or FSCV, and records the transmitted data stream. Filtered data is displayed in various formats, including a background-subtracted plot of sequential FSCV scans - a representation that enables users to distinguish the signatures of various analytes with considerable specificity. Dopamine, glutamate, adenosine and serotonin were selected as analytes for test trials. Proof-of-principle tests included in vitro flow-injection measurements and in vivo measurements in rat and pig. Further testing demonstrated basic functionality in a 3-Tesla MRI unit. WINCS was designed in compliance with consensus standards for medical electrical device safety, and it is anticipated that its capability for real-time intraoperative monitoring of neurotransmitter release at an implanted sensor will prove useful for advancing functional neurosurgery.

  17. Wireless Instantaneous Neurotransmitter Concentration Sensing System (WINCS) for Intraoperative Neurochemical Monitoring

    PubMed Central

    Kimble, Christopher J.; Johnson, David M.; Winter, Bruce A.; Whitlock, Sidney V.; Kressin, Kenneth R.; Horne, April E.; Robinson, Justin C.; Bledsoe, Jonathan M.; Tye, Susannah J.; Chang, Su-Youne; Agnesi, Filippo; Griessenauer, Christoph J.; Covey, Daniel; Shon, Young-Min; Bennet, Kevin E.; Garris, Paul A.; Lee, Kendall H.

    2010-01-01

    The Wireless Instantaneous Neurotransmitter Concentration Sensing System (WINCS) measures extracellular neurotransmitter concentration in vivo and displays the data graphically in nearly real time. WINCS implements two electroanalytical methods, fast-scan cyclic voltammetry (FSCV) and fixed-potential amperometry (FPA), to measure neurotransmitter concentrations at an electrochemical sensor, typically a carbon-fiber microelectrode. WINCS comprises a battery-powered patient module and a custom software application (WINCSware) running on a nearby personal computer. The patient module impresses upon the electrochemical sensor either a constant potential (for FPA) or a time-varying waveform (for FSCV). A transimpedance amplifier converts the resulting current to a signal that is digitized and transmitted to the base station via a Bluetooth® radio link. WINCSware controls the operational parameters for FPA or FSCV, and records the transmitted data stream. Filtered data is displayed in various formats, including a background-subtracted plot of sequential FSCV scans—a representation that enables users to distinguish the signatures of various analytes with considerable specificity. Dopamine, glutamate, adenosine and serotonin were selected as analytes for test trials. Proof-of-principle tests included in vitro flow-injection measurements and in vivo measurements in rat and pig. Further testing demonstrated basic functionality in a 3-Tesla MRI unit. WINCS was designed in compliance with consensus standards for medical electrical device safety, and it is anticipated that its capability for real-time intraoperative monitoring of neurotransmitter release at an implanted sensor will prove useful for advancing functional neurosurgery. PMID:19963865

  18. Aligning the unalignable: bacteriophage whole genome alignments.

    PubMed

    Bérard, Sèverine; Chateau, Annie; Pompidor, Nicolas; Guertin, Paul; Bergeron, Anne; Swenson, Krister M

    2016-01-13

    In recent years, many studies focused on the description and comparison of large sets of related bacteriophage genomes. Due to the peculiar mosaic structure of these genomes, few informative approaches for comparing whole genomes exist: dot plots diagrams give a mostly qualitative assessment of the similarity/dissimilarity between two or more genomes, and clustering techniques are used to classify genomes. Multiple alignments are conspicuously absent from this scene. Indeed, whole genome aligners interpret lack of similarity between sequences as an indication of rearrangements, insertions, or losses. This behavior makes them ill-prepared to align bacteriophage genomes, where even closely related strains can accomplish the same biological function with highly dissimilar sequences. In this paper, we propose a multiple alignment strategy that exploits functional collinearity shared by related strains of bacteriophages, and uses partial orders to capture mosaicism of sets of genomes. As classical alignments do, the computed alignments can be used to predict that genes have the same biological function, even in the absence of detectable similarity. The Alpha aligner implements these ideas in visual interactive displays, and is used to compute several examples of alignments of Staphylococcus aureus and Mycobacterium bacteriophages, involving up to 29 genomes. Using these datasets, we prove that Alpha alignments are at least as good as those computed by standard aligners. Comparison with the progressive Mauve aligner - which implements a partial order strategy, but whose alignments are linearized - shows a greatly improved interactive graphic display, while avoiding misalignments. Multiple alignments of whole bacteriophage genomes work, and will become an important conceptual and visual tool in comparative genomics of sets of related strains. A python implementation of Alpha, along with installation instructions for Ubuntu and OSX, is available on bitbucket (https://bitbucket.org/thekswenson/alpha).

  19. Does ecophysiology mediate reptile responses to fire regimes? Evidence from Iberian lizards

    PubMed Central

    Ferreira, Catarina C.; Santos, Xavier

    2016-01-01

    Background. Reptiles are sensitive to habitat disturbance induced by wildfires but species frequently show opposing responses. Functional causes of such variability have been scarcely explored. In the northernmost limit of the Mediterranean bioregion, lizard species of Mediterranean affinity (Psammodromus algirus and Podarcis guadarramae) increase in abundance in burnt areas whereas Atlantic species (Lacerta schreiberi and Podarcis bocagei) decrease. Timon lepidus, the largest Mediterranean lizard in the region, shows mixed responses depending on the locality and fire history. We tested whether such interspecific differences are of a functional nature, namely, if ecophysiological traits may determine lizard response to fire. Based on the variation in habitat structure between burnt and unburnt sites, we hypothesise that Mediterranean species, which increase density in open habitats promoted by frequent fire regimes, should be more thermophile and suffer lower water losses than Atlantic species. Methods. We submitted 6–10 adult males of the five species to standard experiments for assessing preferred body temperatures (Tp) and evaporativewater loss rates (EWL), and examined the variation among species and along time by means of repeated-measures AN(C)OVAs. Results. Results only partially supported our initial expectations, since the medium-sized P. algirus clearly attained higher Tp and lower EWL. The two small wall lizards (P. bocagei and P. guadarramae) displayed low Tp and high EWL while the two large green lizards (T. lepidus and L. schreiberi) displayed intermediate values for both parameters. Discussion. The predicted differences according to the biogeographic affinities within each pair were not fully confirmed. We conclude that ecophysiology may help to understand functional reptile responses to fire but other biological traits are also to be considered. PMID:27330864

  20. 49 CFR 236.404 - Signals at adjacent control points.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RULES, STANDARDS, AND INSTRUCTIONS GOVERNING THE INSTALLATION... than restricted speed cannot be displayed simultaneously for conflicting movements. ...

  1. Does Mckuer's Law Hold for Heart Rate Control via Biofeedback Display?

    NASA Technical Reports Server (NTRS)

    Courter, B. J.; Jex, H. R.

    1984-01-01

    Some persons can control their pulse rate with the aid of a biofeedback display. If the biofeedback display is modified to show the error between a command pulse-rate and the measured rate, a compensatory (error correcting) heart rate tracking control loop can be created. The dynamic response characteristics of this control loop when subjected to step and quasi-random disturbances were measured. The control loop includes a beat-to-beat cardiotachmeter differenced with a forcing function from a quasi-random input generator; the resulting error pulse-rate is displayed as feedback. The subject acts to null the displayed pulse-rate error, thereby closing a compensatory control loop. McRuer's Law should hold for this case. A few subjects already skilled in voluntary pulse-rate control were tested for heart-rate control response. Control-law properties are derived, such as: crossover frequency, stability margins, and closed-loop bandwidth. These are evaluated for a range of forcing functions and for step as well as random disturbances.

  2. Real-time graphic display utility for nuclear safety applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, S.; Huang, X.; Taylor, J.

    2006-07-01

    With the increasing interests in the nuclear energy, new nuclear power plants will be constructed and licensed, and older generation ones will be upgraded for assuring continuing operation. The tendency of adopting the latest proven technology and the fact of older parts becoming obsolete have made the upgrades imperative. One of the areas for upgrades is the older CRT display being replaced by the latest graphics displays running under modern real time operating system (RTOS) with safety graded modern computer. HFC has developed a graphic display utility (GDU) under the QNX RTOS. A standard off-the-shelf software with a long historymore » of performance in industrial applications, QNX RTOS used for safety applications has been examined via a commercial dedication process that is consistent with the regulatory guidelines. Through a commercial survey, a design life cycle and an operating history evaluation, and necessary tests dictated by the dedication plan, it is reasonably confirmed that the QNX RTOS was essentially equivalent to what would be expected in the nuclear industry. The developed GDU operates and communicates with the existing equipment through a dedicated serial channel of a flat panel controller (FPC) module. The FPC module drives a flat panel display (FPD) monitor. A touch screen mounted on the FPD serves as the normal operator interface with the FPC/FPD monitor system. The GDU can be used not only for replacing older CRTs but also in new applications. The replacement of the older CRT does not disturb the function of the existing equipment. It not only provides modern proven technology upgrade but also improves human ergonomics. The FPC, which can be used as a standalone controller running with the GDU, is an integrated hardware and software module. It operates as a single board computer within a control system, and applies primarily to the graphics display, targeting, keyboard and mouse. During normal system operation, the GDU has two sources of data input: a serial interface with field equipment and a serial input from the FPD touch screen. The mechanism for data collection from the field equipment consists of the regular exchange of the data update request messages and target commands sent to the equipment and the update messages returned to the FPC. The data updates from field equipment control displays presented on the graphic pages. Touch screen contacts are decoded to identify physical position that was contacted. If that position corresponds with one of the buttons on the graphic page, the software uses that input to initiate the function defined for the particular button contacted. In this paper, the FPC will be illustrated as a standalone system as well as a module in a dedicated control system. The GDU design concepts and its design flow will be demonstrated. The dedication process of the QNX RTOS needed for the GDU will be highlighted. Finally, the GDU with a specific application example used in one of the nuclear power plants will be presented. (authors)« less

  3. Boeing Displays Process Action team

    NASA Astrophysics Data System (ADS)

    Wright, R. Nick; Jacobsen, Alan R.

    2000-08-01

    Boeing uses Active Matrix Liquid Crystal Display (AMLCD) technology in a wide variety of its aerospace products, including military, commercial, and space applications. With the demise of Optical Imaging Systems (OIS) in September 1998, the source of on-shore custom AMLCD products has become very tenuous. Reliance on off-shore sources of AMLCD glass for aerospace products is also difficult when the average life of a display product is often less than one-tenth the 30 or more years expected from aerospace platforms. Boeing is addressing this problem through the development of a Displays Process Action Team that gathers input from all display users across the spectrum of our aircraft products. By consolidating requirements, developing common interface standards, working with our suppliers and constantly monitoring custom sources as well as commercially available products, Boeing is minimizing the impact (current and future) of the uncertain AMLCD avionics supply picture.

  4. The Rendezvous Monitoring Display Capabilities of the Rendezvous and Proximity Operations Program

    NASA Technical Reports Server (NTRS)

    Brazzel, Jack; Spehar, Pete; Clark, Fred; Foster, Chris; Eldridge, Erin

    2013-01-01

    The Rendezvous and Proximity Operations Program (RPOP) is a laptop computer- based relative navigation tool and piloting aid that was developed during the Space Shuttle program. RPOP displays a graphical representation of the relative motion between the target and chaser vehicles in a rendezvous, proximity operations and capture scenario. After being used in over 60 Shuttle rendezvous missions, some of the RPOP display concepts have become recognized as a minimum standard for cockpit displays for monitoring the rendezvous task. To support International Space Station (ISS) based crews in monitoring incoming visiting vehicles, RPOP has been modified to allow crews to compare the Cygnus visiting vehicle s onboard navigated state to processed range measurements from an ISS-based, crew-operated Hand Held Lidar sensor. This paper will discuss the display concepts of RPOP that have proven useful in performing and monitoring rendezvous and proximity operations.

  5. Antibody Fab display and selection through fusion to the pIX coat protein of filamentous phage.

    PubMed

    Tornetta, Mark; Baker, Scott; Whitaker, Brian; Lu, Jin; Chen, Qiang; Pisors, Eileen; Shi, Lei; Luo, Jinquan; Sweet, Raymond; Tsui, Ping

    2010-08-31

    Fab antibody display on filamentous phage is widely applied to de novo antibody discovery and engineering. Here we describe a phagemid system for the efficient display and affinity selection of Fabs through linkage to the minor coat protein pIX. Display was successful by fusion of either Fd or Lc through a short linker to the amino terminus of pIX and co-expression of the counter Lc or Fd as a secreted, soluble fragment. Assembly of functional Fab was confirmed by demonstration of antigen-specific binding using antibodies of known specificity. Phage displaying a Fab specific for RSV-F protein with Fd linked to pIX showed efficient, antigen-specific enrichment when mixed with phage displaying a different specificity. The functionality of this system for antibody engineering was evaluated in an optimization study. A RSV-F protein specific antibody with an affinity of about 2nM was randomized at 4 positions in light chain CDR1. Three rounds of selection with decreasing antigen concentration yielded Fabs with an affinity improvement up to 70-fold and showed a general correlation between enrichment frequency and affinity. We conclude that the pIX coat protein complements other display systems in filamentous phage as an efficient vehicle for low copy display and selection of Fab proteins. 2010 Elsevier B.V. All rights reserved.

  6. A 12-residue epitope displayed on phage T7 reacts strongly with antibodies against foot-and-mouth disease virus.

    PubMed

    Wong, Chuan Loo; Yong, Chean Yeah; Muhamad, Azira; Syahir, Amir; Omar, Abdul Rahman; Sieo, Chin Chin; Tan, Wen Siang

    2018-05-01

    Foot-and-mouth disease (FMD) is a major threat to the livestock industry worldwide. Despite constant surveillance and effective vaccination, the perpetual mutations of the foot-and-mouth disease virus (FMDV) pose a huge challenge to FMD diagnosis. The immunodominant region of the FMDV VP1 protein (residues 131-170) displayed on phage T7 has been used to detect anti-FMDV in bovine sera. In the present study, the functional epitope was further delineated using amino acid sequence alignment, homology modelling and phage display. Two highly conserved regions (VP1 145-152 and VP1 159-170 ) were identified among different FMDV serotypes. The coding regions of these two epitopes were fused separately to the T7 genome and displayed on the phage particles. Interestingly, chimeric phage displaying the VP1 159-170 epitope demonstrated a higher antigenicity than that displaying the VP1 131-170 epitope. By contrast, phage T7 displaying the VP1 145-152 epitope did not react significantly with the anti-FMDV antibodies in vaccinated bovine sera. This study has successfully identified a smaller functional epitope, VP1 159-170 , located at the C-terminal end of the structural VP1 protein. The phage T7 displaying this shorter epitope is a promising diagnostic reagent to detect anti-FMDV antibodies in vaccinated animals.

  7. A novel apparatus for testing binocular function using the 'CyberDome' three-dimensional hemispherical visual display system.

    PubMed

    Handa, T; Ishikawa, H; Shimizu, K; Kawamura, R; Nakayama, H; Sawada, K

    2009-11-01

    Virtual reality has recently been highlighted as a promising medium for visual presentation and entertainment. A novel apparatus for testing binocular visual function using a hemispherical visual display system, 'CyberDome', has been developed and tested. Subjects comprised 40 volunteers (mean age, 21.63 years) with corrected visual acuity of -0.08 (LogMAR) or better, and stereoacuity better than 100 s of arc on the Titmus stereo test. Subjects were able to experience visual perception like being surrounded by visual images, a feature of the 'CyberDome' hemispherical visual display system. Visual images to the right and left eyes were projected and superimposed on the dome screen, allowing test images to be seen independently by each eye using polarizing glasses. The hemispherical visual display was 1.4 m in diameter. Three test parameters were evaluated: simultaneous perception (subjective angle of strabismus), motor fusion amplitude (convergence and divergence), and stereopsis (binocular disparity at 1260, 840, and 420 s of arc). Testing was performed in volunteer subjects with normal binocular vision, and results were compared with those using a major amblyoscope. Subjective angle of strabismus and motor fusion amplitude showed a significant correlation between our test and the major amblyoscope. All subjects could perceive the stereoscopic target with a binocular disparity of 480 s of arc. Our novel apparatus using the CyberDome, a hemispherical visual display system, was able to quantitatively evaluate binocular function. This apparatus offers clinical promise in the evaluation of binocular function.

  8. Effects of heat stress and probiotic supplementation on protein functionality and oxidative stability of ground chicken leg meat during display storage.

    PubMed

    Kim, Hyun-Wook; Kim, Ji-Han; Yan, Feifei; Cheng, Heng-Wei; Brad Kim, Yuan H

    2017-12-01

    The present study aimed to evaluate the effects of heat stress and probiotic supplementation on protein functionality and oxidative stability of ground chicken leg during display storage. Two hundred and forty, 1-day-old male chicks (5 birds per pen) were subjected to four treatments in a 2 (thermoneutral condition at 21 °C and cyclic heat stress at 32-21-32 °C for 10 h day -1 ) × 2 (regular diet with 0 or 0.25 g kg -1 Bacillus subtilis) factorial design. Chickens were harvested at day 46, and pairs of whole legs were collected at 1 day postmortem. The chicken legs were deboned, ground, tray-packaged with oxygen-permeable film, and displayed for 3 days. Heat stress and probiotic supplementation had no impact on pH, water-holding capacity, color, protein functionality, lipid lipolysis and lipid/protein oxidation stability (P > 0.05). Display storage increased the pH and lipid oxidation of ground chicken legs (P < 0.05). In addition, protein oxidation occurred during display storage, as determined via an increased carbonyl group (P = 0.0109) and reduced thiol group (P < 0.0001). The results of the present study indicate that chronic heat stress and probiotic supplementation had no practical adverse impact on protein functionality and oxidative stability of ground chicken leg meat. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  9. Ventral aspect of the visual form pathway is not critical for the perception of biological motion

    PubMed Central

    Gilaie-Dotan, Sharon; Saygin, Ayse Pinar; Lorenzi, Lauren J.; Rees, Geraint; Behrmann, Marlene

    2015-01-01

    Identifying the movements of those around us is fundamental for many daily activities, such as recognizing actions, detecting predators, and interacting with others socially. A key question concerns the neurobiological substrates underlying biological motion perception. Although the ventral “form” visual cortex is standardly activated by biologically moving stimuli, whether these activations are functionally critical for biological motion perception or are epiphenomenal remains unknown. To address this question, we examined whether focal damage to regions of the ventral visual cortex, resulting in significant deficits in form perception, adversely affects biological motion perception. Six patients with damage to the ventral cortex were tested with sensitive point-light display paradigms. All patients were able to recognize unmasked point-light displays and their perceptual thresholds were not significantly different from those of three different control groups, one of which comprised brain-damaged patients with spared ventral cortex (n > 50). Importantly, these six patients performed significantly better than patients with damage to regions critical for biological motion perception. To assess the necessary contribution of different regions in the ventral pathway to biological motion perception, we complement the behavioral findings with a fine-grained comparison between the lesion location and extent, and the cortical regions standardly implicated in biological motion processing. This analysis revealed that the ventral aspects of the form pathway (e.g., fusiform regions, ventral extrastriate body area) are not critical for biological motion perception. We hypothesize that the role of these ventral regions is to provide enhanced multiview/posture representations of the moving person rather than to represent biological motion perception per se. PMID:25583504

  10. 3D video coding: an overview of present and upcoming standards

    NASA Astrophysics Data System (ADS)

    Merkle, Philipp; Müller, Karsten; Wiegand, Thomas

    2010-07-01

    An overview of existing and upcoming 3D video coding standards is given. Various different 3D video formats are available, each with individual pros and cons. The 3D video formats can be separated into two classes: video-only formats (such as stereo and multiview video) and depth-enhanced formats (such as video plus depth and multiview video plus depth). Since all these formats exist of at least two video sequences and possibly additional depth data, efficient compression is essential for the success of 3D video applications and technologies. For the video-only formats the H.264 family of coding standards already provides efficient and widely established compression algorithms: H.264/AVC simulcast, H.264/AVC stereo SEI message, and H.264/MVC. For the depth-enhanced formats standardized coding algorithms are currently being developed. New and specially adapted coding approaches are necessary, as the depth or disparity information included in these formats has significantly different characteristics than video and is not displayed directly, but used for rendering. Motivated by evolving market needs, MPEG has started an activity to develop a generic 3D video standard within the 3DVC ad-hoc group. Key features of the standard are efficient and flexible compression of depth-enhanced 3D video representations and decoupling of content creation and display requirements.

  11. Enhancing Electrophoretic Display Lifetime: Thiol-Polybutadiene Evaporation Barrier Property Response to Network Microstructure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cook, Caitlyn Christian

    An evaporation barrier is required to enhance the lifetime of electrophoretic deposition (EPD) displays. As EPD functions on the basis of reversible deposition and resuspension of colloids suspended in a solvent, evaporation of the solvent ultimately leads to device failure. Incorporation of a thiol-polybutadiene elastomer into EPD displays enabled display lifetime surpassing six months in counting and catalyzed rigid display transition into a flexible package. Final flexible display transition to mass production compels an electronic-ink approach to encapsulate display suspension within an elastomer shell. Final thiol-polybutadiene photosensitive resin network microstructure was idealized to be dense, homogeneous, and expose an elasticmore » response to deformation. Research at hand details an approach to understanding microstructural change within display elastomers. Polybutadiene-based resin properties are modified via polymer chain structure, with and without added aromatic urethane methacrylate difunctionality, and in measuring network response to variation in thiol and initiator concentration. Dynamic mechanical analysis results signify that cross-linked segments within a difunctionalized polybutadiene network were on average eight times more elastically active than that of linked segments within a non-functionalized polybutadiene network. Difunctionalized polybutadiene samples also showed a 2.5 times greater maximum elastic modulus than non-functionalized samples. Hybrid polymer composed of both polybutadiene chains encompassed TE-2000 stiffness and B-1000 elasticity for use in encapsulating display suspension. Later experiments measured kinetic and rheological response due to alteration in dithiol cross-linker chain length via real time Fourier transform infrared spectroscopy and real-time dynamic rheology. Distinct differences were discovered between dithiol resin systems, as maximum thiol conversion achieved in short and long chain length dithiols was 86% and 11%, respectively. Oscillatory real-time rheological experiments confirmed a more uniform network to better dissipate applied shear in short chain length dithiol systems, as long chain length dithiols relayed a steep internal stress build-up due to less cross-links and chain entanglements. Thorough understanding of network formation aids the production of a stronger and impermeable elastomeric barrier for preservation of EPD displays.« less

  12. Transgenic Analysis of the Role of FKBP12.6 in Cardiac Function and Intracellular Calcium Release

    PubMed Central

    Liu, Ying; Chen, Hanying; Ji, Guangju; Li, Baiyan; Mohler, Peter J.; Zhu, Zhiming; Yong, Weidong; Chen, Zhuang; Xu, Xuehong

    2011-01-01

    Abstract FK506 binding protein12.6 (FKBP12.6) binds to the Ca2+ release channel ryanodine receptor (RyR2) in cardiomyocytes and stabilizes RyR2 to prevent premature sarcoplasmic reticulum Ca2+ release. Previously, two different mouse strains deficient in FKBP12.6 were reported to have different abnormal cardiac phenotypes. The first mutant strain displayed sex-dependent cardiac hypertrophy, while the second displayed exercise-induced cardiac arrhythmia and sudden death. In this study, we tested whether FKBP12.6-deficient mice that display hypertrophic hearts can develop exercise-induced cardiac sudden death and whether the hypertrophic heart is a direct consequence of abnormal calcium handling in mutant cardiomyocytes. Our data show that FKBP12.6-deficient mice with cardiac hypertrophy do not display exercise-induced arrhythmia and/or sudden cardiac death. To investigate the role of FKBP12.6 overexpression for cardiac function and cardiomyocyte calcium release, we generated a transgenic mouse line with cardiac specific overexpression of FKBP12.6 using α-myosin heavy chain (αMHC) promoter. MHC-FKBP12.6 mice displayed normal cardiac development and function. We demonstrated that MHC-FKBP12.6 mice are able to rescue abnormal cardiac hypertrophy and abnormal calcium release in FKBP12.6-deficient mice. PMID:22087651

  13. Lightweight genome viewer: portable software for browsing genomics data in its chromosomal context

    PubMed Central

    Faith, Jeremiah J; Olson, Andrew J; Gardner, Timothy S; Sachidanandam, Ravi

    2007-01-01

    Background Lightweight genome viewer (lwgv) is a web-based tool for visualization of sequence annotations in their chromosomal context. It performs most of the functions of larger genome browsers, while relying on standard flat-file formats and bypassing the database needs of most visualization tools. Visualization as an aide to discovery requires display of novel data in conjunction with static annotations in their chromosomal context. With database-based systems, displaying dynamic results requires temporary tables that need to be tracked for removal. Results lwgv simplifies the visualization of user-generated results on a local computer. The dynamic results of these analyses are written to transient files, which can import static content from a more permanent file. lwgv is currently used in many different applications, from whole genome browsers to single-gene RNAi design visualization, demonstrating its applicability in a large variety of contexts and scales. Conclusion lwgv provides a lightweight alternative to large genome browsers for visualizing biological annotations and dynamic analyses in their chromosomal context. It is particularly suited for applications ranging from short sequences to medium-sized genomes when the creation and maintenance of a large software and database infrastructure is not necessary or desired. PMID:17877794

  14. Spatial noise and threshold contrasts in LCD displays

    NASA Astrophysics Data System (ADS)

    Roehrig, Hans; Krupinski, Elizabeth A.; Chawla, Amarpreet S.; Fan, Jiahua; Gandhi, Kunal

    2003-05-01

    This paper presents the results of initial physical and psycho-physical evaluations of the noise of high resolution LCDs. 5 LCDs were involved, having 4 different pixel structures. Spatial as well as temporal noise was physically measured with the aid of a high-performance CCD camera. Human contrast sensitivity in the presence of spatial noise was determined psycho-physically using periodic stimuli (square-wave patterns) as well as aperiodic stimuli (squares). For the measurements of the human contrast sensitivity, all LCDs were calibrated to the DICOM 14 Grayscale Standard Display Function (GSDF). The results demonstrate that spatial noise is the dominant noise in all LCDs, while temporal noise is insignificant and plays only a minor part. The magnitude of spatial noise of LCDs is in the range between that of CRTs with a P104 and that of CRTs with a P45. Of particular importance with respect to LCD noise is the contribution of the pixel structure to the Noise Power Spectrum, which shows up as sharp spikes at spatial frequencies beyond the LCDs" Nyquist frequency. The paper does not offer any clues about the importance of these spikes on the human contrast sensitivity.

  15. Fatigue behaviour of NiTi shape memory alloy scaffolds produced by SLM, a unit cell design comparison.

    PubMed

    Speirs, M; Van Hooreweder, B; Van Humbeeck, J; Kruth, J-P

    2017-06-01

    Selective laser melting (SLM) is an additive manufacturing technique able to produce complex functional parts via successively melting layers of metal powder. This process grants the freedom to design highly complex scaffold components to allow bone ingrowth and aid mechanical anchorage. This paper investigates the compression fatigue behaviour of three different unit cells (octahedron, cellular gyroid and sheet gyroid) of SLM nitinol scaffolds. It was found that triply periodic minimal surfaces display superior static mechanical properties in comparison to conventional octahedron beam lattice structures at identical volume fractions. Fatigue resistance was also found to be highly geometry dependent due to the effects of AM processing techniques on the surface topography and notch sensitivity. Geometries minimising nodal points and the staircase effect displayed the greatest fatigue resistance when normalized to yield strength. Furthermore oxygen analysis showed a large oxygen uptake during SLM processing which must be altered to meet ASTM medical grade standards and may significantly reduce fatigue life. These achieved fatigue properties indicate that NiTi scaffolds produced via SLM can provide sufficient mechanical support over an implants lifetime within stress range values experienced in real life. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Lightweight genome viewer: portable software for browsing genomics data in its chromosomal context.

    PubMed

    Faith, Jeremiah J; Olson, Andrew J; Gardner, Timothy S; Sachidanandam, Ravi

    2007-09-18

    Lightweight genome viewer (lwgv) is a web-based tool for visualization of sequence annotations in their chromosomal context. It performs most of the functions of larger genome browsers, while relying on standard flat-file formats and bypassing the database needs of most visualization tools. Visualization as an aide to discovery requires display of novel data in conjunction with static annotations in their chromosomal context. With database-based systems, displaying dynamic results requires temporary tables that need to be tracked for removal. lwgv simplifies the visualization of user-generated results on a local computer. The dynamic results of these analyses are written to transient files, which can import static content from a more permanent file. lwgv is currently used in many different applications, from whole genome browsers to single-gene RNAi design visualization, demonstrating its applicability in a large variety of contexts and scales. lwgv provides a lightweight alternative to large genome browsers for visualizing biological annotations and dynamic analyses in their chromosomal context. It is particularly suited for applications ranging from short sequences to medium-sized genomes when the creation and maintenance of a large software and database infrastructure is not necessary or desired.

  17. Data and animal management software for large-scale phenotype screening.

    PubMed

    Ching, Keith A; Cooke, Michael P; Tarantino, Lisa M; Lapp, Hilmar

    2006-04-01

    The mouse N-ethyl-N-nitrosourea (ENU) mutagenesis program at the Genomics Institute of the Novartis Research Foundation (GNF) uses MouseTRACS to analyze phenotype screens and manage animal husbandry. MouseTRACS is a Web-based laboratory informatics system that electronically records and organizes mouse colony operations, prints cage cards, tracks inventory, manages requests, and reports Institutional Animal Care and Use Committee (IACUC) protocol usage. For efficient phenotype screening, MouseTRACS identifies mutants, visualizes data, and maps mutations. It displays and integrates phenotype and genotype data using likelihood odds ratio (LOD) plots of genetic linkage between genotype and phenotype. More detailed mapping intervals show individual single nucleotide polymorphism (SNP) markers in the context of phenotype. In addition, dynamically generated pedigree diagrams and inventory reports linked to screening results summarize the inheritance pattern and the degree of penetrance. MouseTRACS displays screening data in tables and uses standard charts such as box plots, histograms, scatter plots, and customized charts looking at clustered mice or cross pedigree comparisons. In summary, MouseTRACS enables the efficient screening, analysis, and management of thousands of animals to find mutant mice and identify novel gene functions. MouseTRACS is available under an open source license at http://www.mousetracs.sourceforge.net.

  18. Individual predictions of eye-movements with dynamic scenes

    NASA Astrophysics Data System (ADS)

    Barth, Erhardt; Drewes, Jan; Martinetz, Thomas

    2003-06-01

    We present a model that predicts saccadic eye-movements and can be tuned to a particular human observer who is viewing a dynamic sequence of images. Our work is motivated by applications that involve gaze-contingent interactive displays on which information is displayed as a function of gaze direction. The approach therefore differs from standard approaches in two ways: (1) we deal with dynamic scenes, and (2) we provide means of adapting the model to a particular observer. As an indicator for the degree of saliency we evaluate the intrinsic dimension of the image sequence within a geometric approach implemented by using the structure tensor. Out of these candidate saliency-based locations, the currently attended location is selected according to a strategy found by supervised learning. The data are obtained with an eye-tracker and subjects who view video sequences. The selection algorithm receives candidate locations of current and past frames and a limited history of locations attended in the past. We use a linear mapping that is obtained by minimizing the quadratic difference between the predicted and the actually attended location by gradient descent. Being linear, the learned mapping can be quickly adapted to the individual observer.

  19. Selective depletion of microglial progranulin in mice is not sufficient to cause neuronal ceroid lipofuscinosis or neuroinflammation.

    PubMed

    Petkau, Terri L; Kosior, Natalia; de Asis, Kathleen; Connolly, Colúm; Leavitt, Blair R

    2017-11-17

    Progranulin deficiency due to heterozygous null mutations in the GRN gene are a common cause of familial frontotemporal lobar degeneration (FTLD), while homozygous loss-of-function GRN mutations are thought to be a rare cause of neuronal ceroid lipofuscinosis (NCL). Aged progranulin-knockout (Grn-null) mice display highly exaggerated lipofuscinosis, microgliosis, and astrogliosis, as well as mild cell loss in specific brain regions. In the brain, progranulin is predominantly expressed in neurons and microglia, and previously, we demonstrated that neuronal-specific depletion of progranulin does not recapitulate the neuropathological phenotype of Grn-null mice. In this study, we evaluated whether selective depletion of progranulin expression in myeloid-lineage cells, including microglia, causes NCL-like neuropathology or neuroinflammation in mice. We generated mice with progranulin depleted in myeloid-lineage cells by crossing mice homozygous for a floxed progranulin allele to mice expressing Cre recombinase under control of the LyzM promotor (Lyz-cKO). Progranulin expression was reduced by approximately 50-70% in isolated microglia compared to WT levels. Lyz-cKO mice aged to 12 months did not display any increase in lipofuscin deposition, microgliosis, or astrogliosis in the four brain regions examined, though increases were observed for many of these measures in Grn-null animals. To evaluate the functional effect of reduced progranulin expression in isolated microglia, primary cultures were stimulated with controlled standard endotoxin and cytokine release was measured. While Grn-null microglia display a hyper-inflammatory phenotype, Lyz-cKO and WT microglia secreted similar levels of inflammatory cytokines. We conclude that progranulin expression from either microglia or neurons is sufficient to prevent the development of NCL-like neuropathology in mice. Furthermore, microglia that are deficient for progranulin expression but isolated from a progranulin-rich environment have a normal inflammatory profile. Our results suggest that progranulin acts, at least partly, in a non-cell autonomous manner in the brain.

  20. Dynamic plasmonic colour display

    NASA Astrophysics Data System (ADS)

    Duan, Xiaoyang; Kamin, Simon; Liu, Na

    2017-02-01

    Plasmonic colour printing based on engineered metasurfaces has revolutionized colour display science due to its unprecedented subwavelength resolution and high-density optical data storage. However, advanced plasmonic displays with novel functionalities including dynamic multicolour printing, animations, and highly secure encryption have remained in their infancy. Here we demonstrate a dynamic plasmonic colour display technique that enables all the aforementioned functionalities using catalytic magnesium metasurfaces. Controlled hydrogenation and dehydrogenation of the constituent magnesium nanoparticles, which serve as dynamic pixels, allow for plasmonic colour printing, tuning, erasing and restoration of colour. Different dynamic pixels feature distinct colour transformation kinetics, enabling plasmonic animations. Through smart material processing, information encoded on selected pixels, which are indiscernible to both optical and scanning electron microscopies, can only be read out using hydrogen as a decoding key, suggesting a new generation of information encryption and anti-counterfeiting applications.

  1. Dynamic plasmonic colour display.

    PubMed

    Duan, Xiaoyang; Kamin, Simon; Liu, Na

    2017-02-24

    Plasmonic colour printing based on engineered metasurfaces has revolutionized colour display science due to its unprecedented subwavelength resolution and high-density optical data storage. However, advanced plasmonic displays with novel functionalities including dynamic multicolour printing, animations, and highly secure encryption have remained in their infancy. Here we demonstrate a dynamic plasmonic colour display technique that enables all the aforementioned functionalities using catalytic magnesium metasurfaces. Controlled hydrogenation and dehydrogenation of the constituent magnesium nanoparticles, which serve as dynamic pixels, allow for plasmonic colour printing, tuning, erasing and restoration of colour. Different dynamic pixels feature distinct colour transformation kinetics, enabling plasmonic animations. Through smart material processing, information encoded on selected pixels, which are indiscernible to both optical and scanning electron microscopies, can only be read out using hydrogen as a decoding key, suggesting a new generation of information encryption and anti-counterfeiting applications.

  2. Dynamic plasmonic colour display

    PubMed Central

    Duan, Xiaoyang; Kamin, Simon; Liu, Na

    2017-01-01

    Plasmonic colour printing based on engineered metasurfaces has revolutionized colour display science due to its unprecedented subwavelength resolution and high-density optical data storage. However, advanced plasmonic displays with novel functionalities including dynamic multicolour printing, animations, and highly secure encryption have remained in their infancy. Here we demonstrate a dynamic plasmonic colour display technique that enables all the aforementioned functionalities using catalytic magnesium metasurfaces. Controlled hydrogenation and dehydrogenation of the constituent magnesium nanoparticles, which serve as dynamic pixels, allow for plasmonic colour printing, tuning, erasing and restoration of colour. Different dynamic pixels feature distinct colour transformation kinetics, enabling plasmonic animations. Through smart material processing, information encoded on selected pixels, which are indiscernible to both optical and scanning electron microscopies, can only be read out using hydrogen as a decoding key, suggesting a new generation of information encryption and anti-counterfeiting applications. PMID:28232722

  3. Interactive cutting path analysis programs

    NASA Technical Reports Server (NTRS)

    Weiner, J. M.; Williams, D. S.; Colley, S. R.

    1975-01-01

    The operation of numerically controlled machine tools is interactively simulated. Four programs were developed to graphically display the cutting paths for a Monarch lathe, Cintimatic mill, Strippit sheet metal punch, and the wiring path for a Standard wire wrap machine. These programs are run on a IMLAC PDS-ID graphic display system under the DOS-3 disk operating system. The cutting path analysis programs accept input via both paper tape and disk file.

  4. An Evaluation of Detect and Avoid Displays for UAS: The Effect of Information Level and Display Location on Pilot Performance

    NASA Technical Reports Server (NTRS)

    Rorie, Conrad; Fern, Lisa; Pack, Jessica; Shively, Jay; Draper, Mark H.

    2015-01-01

    The pilot-in-the-loop Detect-and-Avoid (DAA) task requires the pilot to carry out three major functions: 1) detect a potential threat, 2) determine an appropriate resolution maneuver, and 3) execute that resolution maneuver via the GCS control and navigation interface(s). The purpose of the present study was to examine two main questions with respect to DAA display considerations that could impact pilots ability to maintain well clear from other aircraft. First, what is the effect of a minimum (or basic) information display compared to an advanced information display on pilot performance? Second, what is the effect of display location on UAS pilot performance? Two levels of information level (basic, advanced) were compared across two levels of display location (standalone, integrated), for a total of four displays. The results indicate that the advanced displays had faster overall response times compared to the basic displays, however, there were no significant differences between the standalone and integrated displays.

  5. Minimum Colour Differences Required To Recognise Small Objects On A Colour CRT

    NASA Astrophysics Data System (ADS)

    Phillips, Peter L.

    1985-05-01

    Data is required to assist in the assessment, evaluation and optimisation of colour and other displays for both military and general use. A general aim is to develop a mathematical technique to aid optimisation and reduce the amount of expensive hardware development and trials necessary when introducing new displays. The present standards and methods available for evaluating colour differences are known not to apply to the perception of typical objects on a display. Data is required for irregular objects viewed at small angular subtense ((1°) and relating the recognition of form rather than colour matching. Therefore laboratory experiments have been carried out using a computer controlled CRT to measure the threshold colour difference that an observer requires between object and background so that he can discriminate a variety of similar objects. Measurements are included for a variety of background and object colourings. The results are presented in the CIE colorimetric system similar to current standards used by the display engineer. Apart from the characteristic small field tritanopia, the results show that larger colour differences are required for object recognition than those assumed from conventional colour discrimination data. A simple relationship to account for object size and background colour is suggested to aid visual performance assessments and modelling.

  6. Color Functionality Used in Visual Display for Occupational and Environmental Safety and Managing Color Vision Deficiency.

    PubMed

    Ochiai, Nobuhisa; Kondo, Hiroyuki

    2017-01-01

    The effects of color perception are utilized in visual displays for the purpose of safety in the workplace and in daily life. These effects, generally known as color functionality, are divided into four classifications: visibility, legibility, conspicuity and discriminability. This article focuses on the relationship between the color functionality of color schemes used in visual displays for occupational and environmental safety and color vision deficiency (particularly congenital red-green color deficiency), a critical issue in ophthalmology, and examines the effects of color functionality on the perception of the color red in individuals with protan defects. Due to abrupt system reforms, current Japanese clinical ophthalmology finds itself in a situation where it is insufficiently prepared to handle congenital red-green color deficiencies. Indeed, occupational problems caused by color vision deficiencies have been almost completely neglected, and are an occupational safety and health concern that will need to be solved in the future. This report will present the guidelines for the color vision testing established by the British Health and Safety Executive (HSE), a pioneering example of a model meant to solve these problems. Issues relating to the creation of guidelines adapted to Japanese clinical ophthalmology will also be examined, and we will discuss ways to utilize color functionality used in visual displays for occupational and environmental safety to help manage color vision deficiency.

  7. Assessing Medical Students' Awareness of and Sensitivity to Diverse Health Beliefs Using a Standardized Patient Station.

    ERIC Educational Resources Information Center

    Robins, Lynne S.; White, Casey B.; Alexander, Gwen L.; Gruppen, Larry D.; Grum, Cyril M.

    2001-01-01

    Assessed students' competence in addressing the health beliefs and cultural concerns of a standardized patient, an African American woman with diabetes, during a clinical interview. Found that minority students displayed greater competence in addressing the patient's concerns about altering culturally-based dietary behaviors; white students…

  8. 16 CFR 1616.62 - Policy regarding retail display requirements for items.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... FABRICS ACT REGULATIONS STANDARD FOR THE FLAMMABILITY OF CHILDREN'S SLEEPWEAR: SIZES 7 THROUGH 14 (FF 5-74... which was manufactured before May 1, 1975, and for which a retailer has documentary evidence of compliance with all sampling and testing requirements of the Standard (FF 5-74) (subpart A of this part...

  9. Domain 1: Philosophy and Ethics National Standards for Sport Coaches

    ERIC Educational Resources Information Center

    Jones, Dianne C.

    2004-01-01

    Developing a sound coaching philosophy and displaying ethical behavior is the backbone of effective coaching at any level. Coaches cannot communicate the standards of behavior they expect from their athletes or coaching staff if they have not identified the priorities and values associated with their coaching philosophy. When reflecting on Domain…

  10. Speaking up for Equity Takes Courage--But the Standards Have Your Back

    ERIC Educational Resources Information Center

    Lechtenberg, Kate; Phillips, Jeanie

    2018-01-01

    The National School Library Standards require school librarians to make equity a value that permeates the entire school library community. Creating displays to celebrate diversity is not enough. We cannot allow ourselves to approach diversity as a "social good," in which isolated programs serve marginalized students without challenging…

  11. Chemically defined medium and Caenorhabditis elegans

    NASA Technical Reports Server (NTRS)

    Szewczyk, Nathaniel J.; Kozak, Elena; Conley, Catharine A.

    2003-01-01

    BACKGROUND: C. elegans has been established as a powerful genetic system. Use of a chemically defined medium (C. elegans Maintenance Medium (CeMM)) now allows standardization and systematic manipulation of the nutrients that animals receive. Liquid cultivation allows automated culturing and experimentation and should be of use in large-scale growth and screening of animals. RESULTS: We find that CeMM is versatile and culturing is simple. CeMM can be used in a solid or liquid state, it can be stored unused for at least a year, unattended actively growing cultures may be maintained longer than with standard techniques, and standard C. elegans protocols work well with animals grown in defined medium. We also find that there are caveats to using defined medium. Animals in defined medium grow more slowly than on standard medium, appear to display adaptation to the defined medium, and display altered growth rates as they change the composition of the defined medium. CONCLUSIONS: As was suggested with the introduction of C. elegans as a potential genetic system, use of defined medium with C. elegans should prove a powerful tool.

  12. Helicopter Electro-Optical System Display Requirements. 1. The Effects of CRT Display Size, System Gamma Function, and Terrain Type on Pilots’ Required Display Luminance

    DTIC Science & Technology

    1980-03-01

    full-color terrain model designed to 6 ,. .. ., CINE MA ICiINE h MRO FILM To’ N U Ix v M C CTMIRROR MONITOR FRESNEL REAR- PROJECTION SCREEN Z...ments of NOE flight, recorded on videotape. One segment was filmed at the Hunter-Liggett, Calif., ntilitary reservation, and the other segment was... filmed near Fort Rucker, Ala. The tapes were viewed by each participant pilot on the 13-cm and the 26-cm CRT displays. They could attenuate the display

  13. Purification of functional baculovirus particles from silkworm larval hemolymph and their use as nanoparticles for the detection of human prorenin receptor (PRR) binding

    PubMed Central

    2011-01-01

    Background Baculovirus, which has a width of 40 nm and a length of 250-300 nm, can display functional peptides, receptors and antigens on its surface by their fusion with a baculovirus envelop protein, GP64. In addition, some transmembrane proteins can be displayed without GP64 fusion, using the native transmembrane domains of the baculovirus. We used this functionality to display human prorenin receptor fused with GFPuv (GFPuv-hPRR) on the surface of silkworm Bombyx mori nucleopolyhedrovirus (BmNPV) and then tested whether these baculovirus particles could be used to detect protein-protein interactions. Results BmNPV displaying GFPuv-hPRR (BmNPV-GFPuv-hPRR) was purified from hemolymph by using Sephacryl S-1000 column chromatography in the presence of 0.01% Triton X-100. Its recovery was 86% and the final baculovirus particles number was 4.98 × 108 pfu. Based on the results of enzyme-linked immunosorbent assay (ELISA), 3.1% of the total proteins in BmNPV-GFPuv-hPRR were GFPuv-hPRR. This value was similar to that calculated from the result of western blot by a densitometry (2.7%). To determine whether BmNPV-GFPuv-hPRR particles were bound to human prorenin, ELISA results were compared with those from ELISAs using protease negative BmNPV displaying β1,3-N-acetylglucosaminyltransferase 2 fused with the gene encoding GFPuv (GGT2) (BmNPV-CP--GGT2) particles, which do not display hPRR on their surfaces. Conclusion The display of on the surface of the BmNPV particles will be useful for the detection of protein-protein interactions and the screening of inhibitors and drugs in their roles as nanobioparticles. PMID:21635720

  14. Large-Scale Interaction Profiling of Protein Domains Through Proteomic Peptide-Phage Display Using Custom Peptidomes.

    PubMed

    Seo, Moon-Hyeong; Nim, Satra; Jeon, Jouhyun; Kim, Philip M

    2017-01-01

    Protein-protein interactions are essential to cellular functions and signaling pathways. We recently combined bioinformatics and custom oligonucleotide arrays to construct custom-made peptide-phage libraries for screening peptide-protein interactions, an approach we call proteomic peptide-phage display (ProP-PD). In this chapter, we describe protocols for phage display for the identification of natural peptide binders for a given protein. We finally describe deep sequencing for the analysis of the proteomic peptide-phage display.

  15. Harnessing Novel Secreted Inhibitors of EGF Receptor Signaling for Breast Cancer Treatment

    DTIC Science & Technology

    2007-04-01

    the original proposal, we described approaches for displaying the basic Argos and Dkk scaffolds as pIII fusions on M13 phage , so that we could...deal of effort into displaying Argos and other relevant proteins as pIII fusions on M13 phage (Task 2a). This has been technically very challenging... display function Argos on the surface of phage M13 , requiring a change in experimental strategy • To replace the phage display , we have established

  16. Image standards in tissue-based diagnosis (diagnostic surgical pathology).

    PubMed

    Kayser, Klaus; Görtler, Jürgen; Goldmann, Torsten; Vollmer, Ekkehard; Hufnagl, Peter; Kayser, Gian

    2008-04-18

    Progress in automated image analysis, virtual microscopy, hospital information systems, and interdisciplinary data exchange require image standards to be applied in tissue-based diagnosis. To describe the theoretical background, practical experiences and comparable solutions in other medical fields to promote image standards applicable for diagnostic pathology. THEORY AND EXPERIENCES: Images used in tissue-based diagnosis present with pathology-specific characteristics. It seems appropriate to discuss their characteristics and potential standardization in relation to the levels of hierarchy in which they appear. All levels can be divided into legal, medical, and technological properties. Standards applied to the first level include regulations or aims to be fulfilled. In legal properties, they have to regulate features of privacy, image documentation, transmission, and presentation; in medical properties, features of disease-image combination, human-diagnostics, automated information extraction, archive retrieval and access; and in technological properties features of image acquisition, display, formats, transfer speed, safety, and system dynamics. The next lower second level has to implement the prescriptions of the upper one, i.e. describe how they are implemented. Legal aspects should demand secure encryption for privacy of all patient related data, image archives that include all images used for diagnostics for a period of 10 years at minimum, accurate annotations of dates and viewing, and precise hardware and software information. Medical aspects should demand standardized patients' files such as DICOM 3 or HL 7 including history and previous examinations, information of image display hardware and software, of image resolution and fields of view, of relation between sizes of biological objects and image sizes, and of access to archives and retrieval. Technological aspects should deal with image acquisition systems (resolution, colour temperature, focus, brightness, and quality evaluation procedures), display resolution data, implemented image formats, storage, cycle frequency, backup procedures, operation system, and external system accessibility. The lowest third level describes the permitted limits and threshold in detail. At present, an applicable standard including all mentioned features does not exist to our knowledge; some aspects can be taken from radiological standards (PACS, DICOM 3); others require specific solutions or are not covered yet. The progress in virtual microscopy and application of artificial intelligence (AI) in tissue-based diagnosis demands fast preparation and implementation of an internationally acceptable standard. The described hierarchic order as well as analytic investigation in all potentially necessary aspects and details offers an appropriate tool to specifically determine standardized requirements.

  17. Development of rehabilitation training support system for occupational therapy of upper limb motor function

    NASA Astrophysics Data System (ADS)

    Morita, Yoshifumi; Hirose, Akinori; Uno, Takashi; Uchid, Masaki; Ukai, Hiroyuki; Matsui, Nobuyuki

    2007-12-01

    In this paper we propose a new rehabilitation training support system for upper limbs. The proposed system enables therapists to quantitatively evaluate the therapeutic effect of upper limb motor function during training, to easily change the load of resistance of training and to easily develop a new training program suitable for the subjects. For this purpose we develop control algorithms of training programs in the 3D force display robot. The 3D force display robot has parallel link mechanism with three motors. The control algorithm simulating sanding training is developed for the 3D force display robot. Moreover the teaching/training function algorithm is developed. It enables the therapists to easily make training trajectory suitable for subject's condition. The effectiveness of the developed control algorithms is verified by experiments.

  18. A comparison of tracking with visual and kinesthetic-tactual displays

    NASA Technical Reports Server (NTRS)

    Jagacinski, R. J.; Flach, J. M.; Gilson, R. D.

    1981-01-01

    Recent research on manual tracking with a kinesthetic-tactual (KT) display suggests that under appropriate conditions it may be an effective means of providing visual workload relief. In order to better understand how KT tracking differs from visual tracking, both a critical tracking task and stationary single-axis tracking tasks were conducted with and without velocity quickening. On the critical tracking task, the visual displays were superior; however, the KT quickened display was approximately equal to the visual unquickened display. Mean squared error scores in the stationary tracking tasks for the visual and KT displays were approximately equal in the quickened conditions, and the describing functions were very similar. In the unquickened conditions, the visual display was superior. Subjects using the unquickened KT display exhibited a low frequency lead-lag that may be related to sensory adaptation.

  19. Advanced electronic displays and their potential in future transport aircraft

    NASA Technical Reports Server (NTRS)

    Hatfield, J. J.

    1981-01-01

    It is pointed out that electronic displays represent one of the keys to continued integration and improvement of the effectiveness of avionic systems in future transport aircraft. An employment of modern electronic display media and generation has become vital in connection with the increases in modes and functions of modern aircraft. Requirements for electronic systems of future transports are examined, and a description is provided of the tools which are available for cockpit integration, taking into account trends in information processing and presentation, trends in integrated display devices, and trends concerning input/output devices. Developments related to display media, display generation, and I/O devices are considered, giving attention to a comparison of CRT and flat-panel display technology, advanced HUD technology and multifunction controls. Integrated display formats are discussed along with integrated systems and cockpit configurations.

  20. Mobile display technologies: Past developments, present technologies, and future opportunities

    NASA Astrophysics Data System (ADS)

    Ohshima, Hiroyuki

    2014-01-01

    It has been thirty years since the first active matrix (AM) flat panel display (FPD) was industrialized for portable televisions (TVs) in 1984. The AM FPD has become a dominant electronic display technology widely used from mobile displays to large TVs. The development of AM FPDs for mobile displays has significantly changed our lives by enabling new applications, such as notebook personal computers (PCs), smartphones and tablet PCs. In the future, the role of mobile displays will become even more important, since mobile displays are the live interface for the world of mobile communications in the era of ubiquitous networks. Various developments are being conducted to improve visual performance, reduce power consumption and add new functionality. At the same time, innovative display concepts and novel manufacturing technologies are being investigated to create new values.

  1. Network, system, and status software enhancements for the autonomously managed electrical power system breadboard. Volume 4: Graphical status display

    NASA Technical Reports Server (NTRS)

    Mckee, James W.

    1990-01-01

    This volume (4 of 4) contains the description, structured flow charts, prints of the graphical displays, and source code to generate the displays for the AMPS graphical status system. The function of these displays is to present to the manager of the AMPS system a graphical status display with the hot boxes that allow the manager to get more detailed status on selected portions of the AMPS system. The development of the graphical displays is divided into two processes; the creation of the screen images and storage of them in files on the computer, and the running of the status program which uses the screen images.

  2. Advanced symbology for general aviation approach to landing displays

    NASA Technical Reports Server (NTRS)

    Bryant, W. H.

    1983-01-01

    A set of flight tests designed to evaluate the relative utility of candidate displays with advanced symbology for general aviation terminal area instrument flight rules operations are discussed. The symbology was previously evaluated as part of the NASA Langley Research Center's Terminal Configured Vehicle Program for use in commercial airlines. The advanced symbology included vehicle track angle, flight path angle and a perspective representation of the runway. These symbols were selectively drawn on a cathode ray tube (CRT) display along with the roll attitude, pitch attitude, localizer deviation and glideslope deviation. In addition to the CRT display, the instrument panel contained standard turn and bank, altimeter, rate of climb, airspeed, heading, and engine instruments. The symbology was evaluated using tracking performance and pilot subjective ratings for an instrument landing system capture and tracking task.

  3. Functional polycarbonates and their self-assemblies as promising non-viral vectors.

    PubMed

    Seow, Wei Yang; Yang, Yi Yan

    2009-10-01

    Polycarbonates are promising biomaterials due to their biocompatibility, degradability and low toxicity. In this study, a series of COOH-functionalized polycarbonates was synthesized via an organocatalytic ring opening polymerization pathway under mild conditions. The polymers displayed a range of molecular weights (M(w): 3.1, 5.5 and 9.7 kDa) and were very narrowly distributed (polydispersity index: 1.07, 1.07 and 1.15 respectively). Aliphatic amines with different chain lengths (triethylenetetramine, tetraethylenepentamine or pentaethylenehexamine) were then conjugated onto the polycarbonate backbone using DIC/NHS chemistry. These amine-functionalized polycarbonates could form nanoparticles upon simple dissolution in water and had CMC values ranging from 22 to 45 mg/L. It was found that a longer amine chain resulted in greater buffering capacity, more positive zeta potential and smaller hydrodynamic size of the polymeric nanoparticles. Results from gel retardation assays indicated that the polymers were able to condense DNA. In-vitro studies further demonstrated that selected amine-functionalized polycarbonates could mediate efficient luciferase expression in HEK293, HepG2 and 4T1 cell lines at levels that were comparable, or even superior, to the polyethylenimine (PEI) standard. Importantly, minimal cytotoxicty was induced in the cells. These functional polycarbonates therefore have the potential to be a useful non-viral vector for gene therapy.

  4. Scanning tunneling microscopy image simulation of the rutile (110) TiO2 surface with hybrid functionals and the localized basis set approach

    NASA Astrophysics Data System (ADS)

    Di Valentin, Cristiana

    2007-10-01

    In this work we present a simplified procedure to use hybrid functionals and localized atomic basis sets to simulate scanning tunneling microscopy (STM) images of stoichiometric, reduced and hydroxylated rutile (110) TiO2 surface. For the two defective systems it is necessary to introduce some exact Hartree-Fock exchange in the exchange functional in order to correctly describe the details of the electronic structure. Results are compared to the standard density functional theory and planewave basis set approach. Both methods have advantages and drawbacks that are analyzed in detail. In particular, for the localized basis set approach, it is necessary to introduce a number of Gaussian function in the vacuum region above the surface in order to correctly describe the exponential decay of the integrated local density of states from the surface. In the planewave periodic approach, a thick vacuum region is required to achieve correct results. Simulated STM images are obtained for both the reduced and hydroxylated surface which nicely compare with experimental findings. A direct comparison of the two defects as displayed in the simulated STM images indicates that the OH groups should appear brighter than oxygen vacancies in perfect agreement with the experimental STM data.

  5. The Art Gallery Test: A Preliminary Comparison between Traditional Neuropsychological and Ecological VR-Based Tests.

    PubMed

    Gamito, Pedro; Oliveira, Jorge; Alghazzawi, Daniyal; Fardoun, Habib; Rosa, Pedro; Sousa, Tatiana; Maia, Ines; Morais, Diogo; Lopes, Paulo; Brito, Rodrigo

    2017-01-01

    Ecological validity should be the cornerstone of any assessment of cognitive functioning. For this purpose, we have developed a preliminary study to test the Art Gallery Test (AGT) as an alternative to traditional neuropsychological testing. The AGT involves three visual search subtests displayed in a virtual reality (VR) art gallery, designed to assess visual attention within an ecologically valid setting. To evaluate the relation between AGT and standard neuropsychological assessment scales, data were collected on a normative sample of healthy adults ( n = 30). The measures consisted of concurrent paper-and-pencil neuropsychological measures [Montreal Cognitive Assessment (MoCA), Frontal Assessment Battery (FAB), and Color Trails Test (CTT)] along with the outcomes from the three subtests of the AGT. The results showed significant correlations between the AGT subtests describing different visual search exercises strategies with global and specific cognitive measures. Comparative visual search was associated with attention and cognitive flexibility (CTT); whereas visual searches involving pictograms correlated with global cognitive function (MoCA).

  6. Synthesis and evaluation of 2-chloroethylnitrosoureas of substituted naphthalimides as mixed-function anticancer compounds.

    PubMed

    Samanta, S; Pain, A; Dutta, S; Sanyal, U

    2001-01-01

    New mixed function anticancer compounds as 2-chloroethylnitrosoureas of substituted naphthalimides represented by bromonap-NU 4a and chloronap-NU 4b, have been synthesized from 4-bromo- and 4-chloro-l,8-naphthalic anhydride, respectively following a 3-step process. Their chemical alkylating activity compared with nor -HN2 indicated that they possess greater alkylating activity than the latter. Their antitumour efficacies were assessed in vivo in two murine ascites tumours, namely Ehrlich ascites carcinoma (EAC) and Sarcoma-180 (S-180) by measuring the increase in median survival times (MST) of drug treated (T) over untreated control (C) mice. Two standard clinical drugs namely endoxan (cyclophosphamide) and 5-fluorouracil (5-FU) were used as positive controls for comparison. Both of them have displayed substantial and reproducible antitumoral activity in these tumours comparable with 5-FU. These were further screened in vitro in 6 different human tumour cell lines but no significant activity was observed in those lines.

  7. Operator vision aids for space teleoperation assembly and servicing

    NASA Technical Reports Server (NTRS)

    Brooks, Thurston L.; Ince, Ilhan; Lee, Greg

    1992-01-01

    This paper investigates concepts for visual operator aids required for effective telerobotic control. Operator visual aids, as defined here, mean any operational enhancement that improves man-machine control through the visual system. These concepts were derived as part of a study of vision issues for space teleoperation. Extensive literature on teleoperation, robotics, and human factors was surveyed to definitively specify appropriate requirements. This paper presents these visual aids in three general categories of camera/lighting functions, display enhancements, and operator cues. In the area of camera/lighting functions concepts are discussed for: (1) automatic end effector or task tracking; (2) novel camera designs; (3) computer-generated virtual camera views; (4) computer assisted camera/lighting placement; and (5) voice control. In the technology area of display aids, concepts are presented for: (1) zone displays, such as imminent collision or indexing limits; (2) predictive displays for temporal and spatial location; (3) stimulus-response reconciliation displays; (4) graphical display of depth cues such as 2-D symbolic depth, virtual views, and perspective depth; and (5) view enhancements through image processing and symbolic representations. Finally, operator visual cues (e.g., targets) that help identify size, distance, shape, orientation and location are discussed.

  8. "Head up and eyes out" advances in head mounted displays capabilities

    NASA Astrophysics Data System (ADS)

    Cameron, Alex

    2013-06-01

    There are a host of helmet and head mounted displays, flooding the market place with displays which provide what is essentially a mobile computer display. What sets aviators HMDs apart is that they provide the user with accurate conformal information embedded in the pilots real world view (see through display) where the information presented is intuitive and easy to use because it overlays the real world (mix of sensor imagery, symbolic information and synthetic imagery) and enables them to stay head up, eyes out, - improving their effectiveness, reducing workload and improving safety. Such systems are an enabling technology in the provision of enhanced Situation Awareness (SA) and reducing user workload in high intensity situations. Safety Is Key; so the addition of these HMD functions cannot detract from the aircrew protection functions of conventional aircrew helmets which also include life support and audio communications. These capabilities are finding much wider application in new types of compact man mounted audio/visual products enabled by the emergence of new families of micro displays, novel optical concepts and ultra-compact low power processing solutions. This papers attempts to capture the key drivers and needs for future head mounted systems for aviation applications.

  9. Image Quality Characteristics of Handheld Display Devices for Medical Imaging

    PubMed Central

    Yamazaki, Asumi; Liu, Peter; Cheng, Wei-Chung; Badano, Aldo

    2013-01-01

    Handheld devices such as mobile phones and tablet computers have become widespread with thousands of available software applications. Recently, handhelds are being proposed as part of medical imaging solutions, especially in emergency medicine, where immediate consultation is required. However, handheld devices differ significantly from medical workstation displays in terms of display characteristics. Moreover, the characteristics vary significantly among device types. We investigate the image quality characteristics of various handheld devices with respect to luminance response, spatial resolution, spatial noise, and reflectance. We show that the luminance characteristics of the handheld displays are different from those of workstation displays complying with grayscale standard target response suggesting that luminance calibration might be needed. Our results also demonstrate that the spatial characteristics of handhelds can surpass those of medical workstation displays particularly for recent generation devices. While a 5 mega-pixel monochrome workstation display has horizontal and vertical modulation transfer factors of 0.52 and 0.47 at the Nyquist frequency, the handheld displays released after 2011 can have values higher than 0.63 at the respective Nyquist frequencies. The noise power spectra for workstation displays are higher than 1.2×10−5 mm2 at 1 mm−1, while handheld displays have values lower than 3.7×10−6 mm2. Reflectance measurements on some of the handheld displays are consistent with measurements for workstation displays with, in some cases, low specular and diffuse reflectance coefficients. The variability of the characterization results among devices due to the different technological features indicates that image quality varies greatly among handheld display devices. PMID:24236113

  10. Offshore fatigue design turbulence

    NASA Astrophysics Data System (ADS)

    Larsen, Gunner C.

    2001-07-01

    Fatigue damage on wind turbines is mainly caused by stochastic loading originating from turbulence. While onshore sites display large differences in terrain topology, and thereby also in turbulence conditions, offshore sites are far more homogeneous, as the majority of them are likely to be associated with shallow water areas. However, despite this fact, specific recommendations on offshore turbulence intensities, applicable for fatigue design purposes, are lacking in the present IEC code. This article presents specific guidelines for such loading. These guidelines are based on the statistical analysis of a large number of wind data originating from two Danish shallow water offshore sites. The turbulence standard deviation depends on the mean wind speed, upstream conditions, measuring height and thermal convection. Defining a population of turbulence standard deviations, at a given measuring position, uniquely by the mean wind speed, variations in upstream conditions and atmospheric stability will appear as variability of the turbulence standard deviation. Distributions of such turbulence standard deviations, conditioned on the mean wind speed, are quantified by fitting the measured data to logarithmic Gaussian distributions. By combining a simple heuristic load model with the parametrized conditional probability density functions of the turbulence standard deviations, an empirical offshore design turbulence intensity is determined. For pure stochastic loading (as associated with standstill situations), the design turbulence intensity yields a fatigue damage equal to the average fatigue damage caused by the distributed turbulence intensity. If the stochastic loading is combined with a periodic deterministic loading (as in the normal operating situation), the proposed design turbulence intensity is shown to be conservative.

  11. Methods for Dichoptic Stimulus Presentation in Functional Magnetic Resonance Imaging - A Review

    PubMed Central

    Choubey, Bhaskar; Jurcoane, Alina; Muckli, Lars; Sireteanu, Ruxandra

    2009-01-01

    Dichoptic stimuli (different stimuli displayed to each eye) are increasingly being used in functional brain imaging experiments using visual stimulation. These studies include investigation into binocular rivalry, interocular information transfer, three-dimensional depth perception as well as impairments of the visual system like amblyopia and stereodeficiency. In this paper, we review various approaches of displaying dichoptic stimulus used in functional magnetic resonance imaging experiments. These include traditional approaches of using filters (red-green, red-blue, polarizing) with optical assemblies as well as newer approaches of using bi-screen goggles. PMID:19526076

  12. A Comparative Study of the Use and Understanding of Self-Presentational Display Rules in Children with High Functioning Autism and Asperger's Disorder

    ERIC Educational Resources Information Center

    Barbaro, Josephine; Dissanayake, Cheryl

    2007-01-01

    The use and understanding of self-presentational display rules (SPDRs) was investigated in 21 children with high-functioning autism (FHA), 18 children with Asperger's disorder (AspD) and 20 typically developing (TD) children (all male, aged 4- to 11-years, matched on mental age). Their behaviour was coded during a deception scenario to assess use…

  13. Parent ratings of executive functioning in children with shunted hydrocephalus.

    PubMed

    Lacy, Maureen; Baldassarre, Megan; Nader, Todd; Frim, David

    2012-01-01

    The present study examined the executive functioning of a group of children with a history of communicating hydrocephalus and how their level of functioning was correlated with parent ratings of executive functioning. The study examined the executive functioning of 39 shunted children with a history of hydrocephalus and 20 healthy peers. Additionally, parents of both groups of children completed the Behavior Rating Inventory of Executive Function (BRIEF) to assess the parents' perceptions of their children's executive functioning. Finally, the study investigated the relationship between the shunted hydrocephalus children's executive functioning and the parent ratings of their executive functioning. Overall, the children with a history of shunted hydrocephalus displayed more executive dysfunction than their healthy peers. These children were rated by their parents as having more executive dysfunction than their healthy peers and displaying working memory, initiation, mental flexibility and self-monitoring difficulties, which appear to increase with age among the shunted hydrocephalus group. While parent ratings as measured by the BRIEF indices did not correlate with all executive tasks within the shunted hydrocephalus group, the cognitive tests assessing mental flexibility may be sensitive to the problems noted by parents at home. The children with a history of shunted hydrocephalus displayed executive functioning deficits on formal examination. The parents of children with a history of shunted hydrocephalus report ongoing executive difficulties which may increase with age. Copyright © 2012 S. Karger AG, Basel.

  14. Excitation energies of dissociating H2: A problematic case for the adiabatic approximation of time-dependent density functional theory

    NASA Astrophysics Data System (ADS)

    Gritsenko, O. V.; van Gisbergen, S. J. A.; Görling, A.; Baerends, E. J.

    2000-11-01

    Time-dependent density functional theory (TDDFT) is applied for calculation of the excitation energies of the dissociating H2 molecule. The standard TDDFT method of adiabatic local density approximation (ALDA) totally fails to reproduce the potential curve for the lowest excited singlet 1Σu+ state of H2. Analysis of the eigenvalue problem for the excitation energies as well as direct derivation of the exchange-correlation (xc) kernel fxc(r,r',ω) shows that ALDA fails due to breakdown of its simple spatially local approximation for the kernel. The analysis indicates a complex structure of the function fxc(r,r',ω), which is revealed in a different behavior of the various matrix elements K1c,1cxc (between the highest occupied Kohn-Sham molecular orbital ψ1 and virtual MOs ψc) as a function of the bond distance R(H-H). The effect of nonlocality of fxc(r,r') is modeled by using different expressions for the corresponding matrix elements of different orbitals. Asymptotically corrected ALDA (ALDA-AC) expressions for the matrix elements K12,12xc(στ) are proposed, while for other matrix elements the standard ALDA expressions are retained. This approach provides substantial improvement over the standard ALDA. In particular, the ALDA-AC curve for the lowest singlet excitation qualitatively reproduces the shape of the exact curve. It displays a minimum and approaches a relatively large positive energy at large R(H-H). ALDA-AC also produces a substantial improvement for the calculated lowest triplet excitation, which is known to suffer from the triplet instability problem of the restricted KS ground state. Failure of the ALDA for the excitation energies is related to the failure of the local density as well as generalized gradient approximations to reproduce correctly the polarizability of dissociating H2. The expression for the response function χ is derived to show the origin of the field-counteracting term in the xc potential, which is lacking in the local density and generalized gradient approximations and which is required to obtain a correct polarizability.

  15. Parallel, exhaustive processing underlies logarithmic search functions: Visual search with cortical magnification.

    PubMed

    Wang, Zhiyuan; Lleras, Alejandro; Buetti, Simona

    2018-04-17

    Our lab recently found evidence that efficient visual search (with a fixed target) is characterized by logarithmic Reaction Time (RT) × Set Size functions whose steepness is modulated by the similarity between target and distractors. To determine whether this pattern of results was based on low-level visual factors uncontrolled by previous experiments, we minimized the possibility of crowding effects in the display, compensated for the cortical magnification factor by magnifying search items based on their eccentricity, and compared search performance on such displays to performance on displays without magnification compensation. In both cases, the RT × Set Size functions were found to be logarithmic, and the modulation of the log slopes by target-distractor similarity was replicated. Consistent with previous results in the literature, cortical magnification compensation eliminated most target eccentricity effects. We conclude that the log functions and their modulation by target-distractor similarity relations reflect a parallel exhaustive processing architecture for early vision.

  16. 49 CFR 236.305 - Approach or time locking.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., DEPARTMENT OF TRANSPORTATION RULES, STANDARDS, AND INSTRUCTIONS GOVERNING THE INSTALLATION, INSPECTION... signals displaying aspects with indications more favorable than “proceed at restricted speed.” ...

  17. Neural response in obsessive-compulsive washers depends on individual fit of triggers

    PubMed Central

    Baioui, Ali; Pilgramm, Juliane; Merz, Christian J.; Walter, Bertram; Vaitl, Dieter; Stark, Rudolf

    2013-01-01

    Background: Patients with obsessive-compulsive disorder (OCD) have highly idiosyncratic triggers. To fully understand which role this idiosyncrasy plays in the neurobiological mechanisms behind OCD, it is necessary to elucidate the impact of individualization regarding the applied investigation methods. This functional magnetic resonance imaging (fMRI) study explores the neural correlates of contamination/washing-related OCD with a highly individualized symptom provocation paradigm. Additionally, it is the first study to directly compare individualized and standardized symptom provocation. Methods: Nineteen patients with washing compulsions created individual OCD hierarchies, which later served as instructions to photograph their own individualized stimulus sets. The patients and 19 case-by-case matched healthy controls participated in a symptom provocation fMRI experiment with individualized and standardized stimulus sets created for each patient. Results: OCD patients compared to healthy controls displayed stronger activation in the basal ganglia (nucleus accumbens, nucleus caudatus, pallidum) for individualized symptom provocation. Using standardized symptom provocation, this group comparison led to stronger activation in the nucleus caudatus. The direct comparison of between-group effects for both symptom provocation approaches revealed stronger activation of the orbitofronto-striatal network for individualized symptom provocation. Conclusions: The present study provides insight into the differential impact of individualized and standardized symptom provocation on the orbitofronto-striatal network of OCD washers. Behavioral and neural responses imply a higher symptom-specificity of individualized symptom provocation. PMID:23630478

  18. Simulation and display of macromolecular complexes

    NASA Technical Reports Server (NTRS)

    Nir, S.; Garduno, R.; Rein, R.; Macelroy, R. D.

    1977-01-01

    In association with an investigation of the interaction of proteins with DNA and RNA, an interactive computer program for building, manipulating, and displaying macromolecular complexes has been designed. The system provides perspective, planar, and stereoscopic views on the computer terminal display, as well as views for standard and nonstandard observer locations. The molecule or its parts may be rotated and/or translated in any direction; bond connections may be added or removed by the viewer. Molecular fragments may be juxtaposed in such a way that given bonds are aligned, and given planes and points coincide. Another subroutine provides for the duplication of a given unit such as a DNA or amino-acid base.

  19. Three dimensional audio versus head down TCAS displays

    NASA Technical Reports Server (NTRS)

    Begault, Durand R.; Pittman, Marc T.

    1994-01-01

    The advantage of a head up auditory display was evaluated in an experiment designed to measure and compare the acquisition time for capturing visual targets under two conditions: Standard head down traffic collision avoidance system (TCAS) display, and three-dimensional (3-D) audio TCAS presentation. Ten commercial airline crews were tested under full mission simulation conditions at the NASA Ames Crew-Vehicle Systems Research Facility Advanced Concepts Flight Simulator. Scenario software generated targets corresponding to aircraft which activated a 3-D aural advisory or a TCAS advisory. Results showed a significant difference in target acquisition time between the two conditions, favoring the 3-D audio TCAS condition by 500 ms.

  20. Flexible displays as key for high-value and unique automotive design

    NASA Astrophysics Data System (ADS)

    Isele, Robert

    2011-03-01

    Within the last few years' car industry changed very fast. Information and Communication became more important and displays are now standard in nearly every car. But this is not the only trend which could be recognized in this industry. CO2 emission, fuel price as well as the increasing traffic inside the Mega Cities initialized a big change in the behavior of the customers. The big battle for the car industry will enter the interior extremely fast, and the premium cars need ore innovative design icons. Flexible Displays are one big step that enables totally different designs and a new value of the driver experience.

Top