On the Performance Evaluation of 3D Reconstruction Techniques from a Sequence of Images
NASA Astrophysics Data System (ADS)
Eid, Ahmed; Farag, Aly
2005-12-01
The performance evaluation of 3D reconstruction techniques is not a simple problem to solve. This is not only due to the increased dimensionality of the problem but also due to the lack of standardized and widely accepted testing methodologies. This paper presents a unified framework for the performance evaluation of different 3D reconstruction techniques. This framework includes a general problem formalization, different measuring criteria, and a classification method as a first step in standardizing the evaluation process. Performance characterization of two standard 3D reconstruction techniques, stereo and space carving, is also presented. The evaluation is performed on the same data set using an image reprojection testing methodology to reduce the dimensionality of the evaluation domain. Also, different measuring strategies are presented and applied to the stereo and space carving techniques. These measuring strategies have shown consistent results in quantifying the performance of these techniques. Additional experiments are performed on the space carving technique to study the effect of the number of input images and the camera pose on its performance.
New Techniques to Evaluate the Incendiary Behavior of Insulators
NASA Technical Reports Server (NTRS)
Buhler, Charles; Calle, Carlos; Clements, Sid; Trigwell, Steve; Ritz, Mindy
2008-01-01
New techniques for evaluating the incendiary behavior of insulators is presented. The onset of incendive brush discharges in air is evaluated using standard spark probe techniques for the case simulating approaches of an electrically grounded sphere to a charged insulator in the presence of a flammable atmosphere. However, this standard technique is unsuitable for the case of brush discharges that may occur during the charging-separation process for two insulator materials. We present experimental techniques to evaluate this hazard in the presence of a flammable atmosphere which is ideally suited to measure the incendiary nature of micro-discharges upon separation, a measurement never before performed. Other measurement techniques unique to this study include; surface potential measurements of insulators before, during and after contact and separation, as well as methods to verify fieldmeter calibrations using a charge insulator surface opposed to standard high voltage plates. Key words: Kapton polyimide film, incendiary discharges, brush discharges, contact and frictional electrification, ignition hazards, insulators, contact angle, surface potential measurements.
Standardized pivot shift test improves measurement accuracy.
Hoshino, Yuichi; Araujo, Paulo; Ahlden, Mattias; Moore, Charity G; Kuroda, Ryosuke; Zaffagnini, Stefano; Karlsson, Jon; Fu, Freddie H; Musahl, Volker
2012-04-01
The variability of the pivot shift test techniques greatly interferes with achieving a quantitative and generally comparable measurement. The purpose of this study was to compare the variation of the quantitative pivot shift measurements with different surgeons' preferred techniques to a standardized technique. The hypothesis was that standardizing the pivot shift test would improve consistency in the quantitative evaluation when compared with surgeon-specific techniques. A whole lower body cadaveric specimen was prepared to have a low-grade pivot shift on one side and high-grade pivot shift on the other side. Twelve expert surgeons performed the pivot shift test using (1) their preferred technique and (2) a standardized technique. Electromagnetic tracking was utilized to measure anterior tibial translation and acceleration of the reduction during the pivot shift test. The variation of the measurement was compared between the surgeons' preferred technique and the standardized technique. The anterior tibial translation during pivot shift test was similar between using surgeons' preferred technique (left 24.0 ± 4.3 mm; right 15.5 ± 3.8 mm) and using standardized technique (left 25.1 ± 3.2 mm; right 15.6 ± 4.0 mm; n.s.). However, the variation in acceleration was significantly smaller with the standardized technique (left 3.0 ± 1.3 mm/s(2); right 2.5 ± 0.7 mm/s(2)) compared with the surgeons' preferred technique (left 4.3 ± 3.3 mm/s(2); right 3.4 ± 2.3 mm/s(2); both P < 0.01). Standardizing the pivot shift test maneuver provides a more consistent quantitative evaluation and may be helpful in designing future multicenter clinical outcome trials. Diagnostic study, Level I.
A new technique for measuring listening and reading literacy in developing countries
NASA Astrophysics Data System (ADS)
Greene, Barbara A.; Royer, James M.; Anzalone, Stephen
1990-03-01
One problem in evaluating educational interventions in developing countries is the absence of tests that adequately reflect the culture and curriculum. The Sentence Verification Technique is a new procedure for measuring reading and listening comprehension that allows for the development of tests based on materials indigenous to a given culture. The validity of using the Sentence Verification Technique to measure reading comprehension in Grenada was evaluated in the present study. The study involved 786 students at standards 3, 4 and 5. The tests for each standard consisted of passages that varied in difficulty. The students identified as high ability students in all three standards performed better than those identified as low ability. All students performed better with easier passages. Additionally, students in higher standards performed bettter than students in lower standards on a given passage. These results supported the claim that the Sentence Verification Technique is a valid measure of reading comprehension in Grenada.
Double row equivalent for rotator cuff repair: A biomechanical analysis of a new technique.
Robinson, Sean; Krigbaum, Henry; Kramer, Jon; Purviance, Connor; Parrish, Robin; Donahue, Joseph
2018-06-01
There are numerous configurations of double row fixation for rotator cuff tears however, there remains to be a consensus on the best method. In this study, we evaluated three different double-row configurations, including a new method. Our primary question is whether the new anchor and technique compares in biomechanical strength to standard double row techniques. Eighteen prepared fresh frozen bovine infraspinatus tendons were randomized to one of three groups including the New Double Row Equivalent, Arthrex Speedbridge and a transosseous equivalent using standard Stabilynx anchors. Biomechanical testing was performed on humeri sawbones and ultimate load, strain, yield strength, contact area, contact pressure, and a survival plots were evaluated. The new double row equivalent method demonstrated increased survival as well as ultimate strength at 415N compared to the remainder testing groups as well as equivalent contact area and pressure to standard double row techniques. This new anchor system and technique demonstrated higher survival rates and loads to failure than standard double row techniques. This data provides us with a new method of rotator cuff fixation which should be further evaluated in the clinical setting. Basic science biomechanical study.
Jha, Abhinav K; Song, Na; Caffo, Brian; Frey, Eric C
2015-04-13
Quantitative single-photon emission computed tomography (SPECT) imaging is emerging as an important tool in clinical studies and biomedical research. There is thus a need for optimization and evaluation of systems and algorithms that are being developed for quantitative SPECT imaging. An appropriate objective method to evaluate these systems is by comparing their performance in the end task that is required in quantitative SPECT imaging, such as estimating the mean activity concentration in a volume of interest (VOI) in a patient image. This objective evaluation can be performed if the true value of the estimated parameter is known, i.e. we have a gold standard. However, very rarely is this gold standard known in human studies. Thus, no-gold-standard techniques to optimize and evaluate systems and algorithms in the absence of gold standard are required. In this work, we developed a no-gold-standard technique to objectively evaluate reconstruction methods used in quantitative SPECT when the parameter to be estimated is the mean activity concentration in a VOI. We studied the performance of the technique with realistic simulated image data generated from an object database consisting of five phantom anatomies with all possible combinations of five sets of organ uptakes, where each anatomy consisted of eight different organ VOIs. Results indicate that the method provided accurate ranking of the reconstruction methods. We also demonstrated the application of consistency checks to test the no-gold-standard output.
On Evaluating Brain Tissue Classifiers without a Ground Truth
Martin-Fernandez, Marcos; Ungar, Lida; Nakamura, Motoaki; Koo, Min-Seong; McCarley, Robert W.; Shenton, Martha E.
2009-01-01
In this paper, we present a set of techniques for the evaluation of brain tissue classifiers on a large data set of MR images of the head. Due to the difficulty of establishing a gold standard for this type of data, we focus our attention on methods which do not require a ground truth, but instead rely on a common agreement principle. Three different techniques are presented: the Williams’ index, a measure of common agreement; STAPLE, an Expectation Maximization algorithm which simultaneously estimates performance parameters and constructs an estimated reference standard; and Multidimensional Scaling, a visualization technique to explore similarity data. We apply these different evaluation methodologies to a set eleven different segmentation algorithms on forty MR images. We then validate our evaluation pipeline by building a ground truth based on human expert tracings. The evaluations with and without a ground truth are compared. Our findings show that comparing classifiers without a gold standard can provide a lot of interesting information. In particular, outliers can be easily detected, strongly consistent or highly variable techniques can be readily discriminated, and the overall similarity between different techniques can be assessed. On the other hand, we also find that some information present in the expert segmentations is not captured by the automatic classifiers, suggesting that common agreement alone may not be sufficient for a precise performance evaluation of brain tissue classifiers. PMID:17532646
Jha, Abhinav K.; Mena, Esther; Caffo, Brian; Ashrafinia, Saeed; Rahmim, Arman; Frey, Eric; Subramaniam, Rathan M.
2017-01-01
Abstract. Recently, a class of no-gold-standard (NGS) techniques have been proposed to evaluate quantitative imaging methods using patient data. These techniques provide figures of merit (FoMs) quantifying the precision of the estimated quantitative value without requiring repeated measurements and without requiring a gold standard. However, applying these techniques to patient data presents several practical difficulties including assessing the underlying assumptions, accounting for patient-sampling-related uncertainty, and assessing the reliability of the estimated FoMs. To address these issues, we propose statistical tests that provide confidence in the underlying assumptions and in the reliability of the estimated FoMs. Furthermore, the NGS technique is integrated within a bootstrap-based methodology to account for patient-sampling-related uncertainty. The developed NGS framework was applied to evaluate four methods for segmenting lesions from F-Fluoro-2-deoxyglucose positron emission tomography images of patients with head-and-neck cancer on the task of precisely measuring the metabolic tumor volume. The NGS technique consistently predicted the same segmentation method as the most precise method. The proposed framework provided confidence in these results, even when gold-standard data were not available. The bootstrap-based methodology indicated improved performance of the NGS technique with larger numbers of patient studies, as was expected, and yielded consistent results as long as data from more than 80 lesions were available for the analysis. PMID:28331883
Jha, Abhinav K; Caffo, Brian; Frey, Eric C
2016-01-01
The objective optimization and evaluation of nuclear-medicine quantitative imaging methods using patient data is highly desirable but often hindered by the lack of a gold standard. Previously, a regression-without-truth (RWT) approach has been proposed for evaluating quantitative imaging methods in the absence of a gold standard, but this approach implicitly assumes that bounds on the distribution of true values are known. Several quantitative imaging methods in nuclear-medicine imaging measure parameters where these bounds are not known, such as the activity concentration in an organ or the volume of a tumor. We extended upon the RWT approach to develop a no-gold-standard (NGS) technique for objectively evaluating such quantitative nuclear-medicine imaging methods with patient data in the absence of any ground truth. Using the parameters estimated with the NGS technique, a figure of merit, the noise-to-slope ratio (NSR), can be computed, which can rank the methods on the basis of precision. An issue with NGS evaluation techniques is the requirement of a large number of patient studies. To reduce this requirement, the proposed method explored the use of multiple quantitative measurements from the same patient, such as the activity concentration values from different organs in the same patient. The proposed technique was evaluated using rigorous numerical experiments and using data from realistic simulation studies. The numerical experiments demonstrated that the NSR was estimated accurately using the proposed NGS technique when the bounds on the distribution of true values were not precisely known, thus serving as a very reliable metric for ranking the methods on the basis of precision. In the realistic simulation study, the NGS technique was used to rank reconstruction methods for quantitative single-photon emission computed tomography (SPECT) based on their performance on the task of estimating the mean activity concentration within a known volume of interest. Results showed that the proposed technique provided accurate ranking of the reconstruction methods for 97.5% of the 50 noise realizations. Further, the technique was robust to the choice of evaluated reconstruction methods. The simulation study pointed to possible violations of the assumptions made in the NGS technique under clinical scenarios. However, numerical experiments indicated that the NGS technique was robust in ranking methods even when there was some degree of such violation. PMID:26982626
Jha, Abhinav K; Caffo, Brian; Frey, Eric C
2016-04-07
The objective optimization and evaluation of nuclear-medicine quantitative imaging methods using patient data is highly desirable but often hindered by the lack of a gold standard. Previously, a regression-without-truth (RWT) approach has been proposed for evaluating quantitative imaging methods in the absence of a gold standard, but this approach implicitly assumes that bounds on the distribution of true values are known. Several quantitative imaging methods in nuclear-medicine imaging measure parameters where these bounds are not known, such as the activity concentration in an organ or the volume of a tumor. We extended upon the RWT approach to develop a no-gold-standard (NGS) technique for objectively evaluating such quantitative nuclear-medicine imaging methods with patient data in the absence of any ground truth. Using the parameters estimated with the NGS technique, a figure of merit, the noise-to-slope ratio (NSR), can be computed, which can rank the methods on the basis of precision. An issue with NGS evaluation techniques is the requirement of a large number of patient studies. To reduce this requirement, the proposed method explored the use of multiple quantitative measurements from the same patient, such as the activity concentration values from different organs in the same patient. The proposed technique was evaluated using rigorous numerical experiments and using data from realistic simulation studies. The numerical experiments demonstrated that the NSR was estimated accurately using the proposed NGS technique when the bounds on the distribution of true values were not precisely known, thus serving as a very reliable metric for ranking the methods on the basis of precision. In the realistic simulation study, the NGS technique was used to rank reconstruction methods for quantitative single-photon emission computed tomography (SPECT) based on their performance on the task of estimating the mean activity concentration within a known volume of interest. Results showed that the proposed technique provided accurate ranking of the reconstruction methods for 97.5% of the 50 noise realizations. Further, the technique was robust to the choice of evaluated reconstruction methods. The simulation study pointed to possible violations of the assumptions made in the NGS technique under clinical scenarios. However, numerical experiments indicated that the NGS technique was robust in ranking methods even when there was some degree of such violation.
Inexpensive Eddy-Current Standard
NASA Technical Reports Server (NTRS)
Berry, Robert F., Jr.
1985-01-01
Radial crack replicas serve as evaluation standards. Technique entails intimately joining two pieces of appropriate aluminum alloy stock and centering drilled hole through and along interface. Bore surface of hole presents two vertical stock interface lines 180 degrees apart. These lines serve as radial crack defect replicas during eddy-current technique setup and verification.
Simulations of motor unit number estimation techniques
NASA Astrophysics Data System (ADS)
Major, Lora A.; Jones, Kelvin E.
2005-06-01
Motor unit number estimation (MUNE) is an electrodiagnostic procedure used to evaluate the number of motor axons connected to a muscle. All MUNE techniques rely on assumptions that must be fulfilled to produce a valid estimate. As there is no gold standard to compare the MUNE techniques against, we have developed a model of the relevant neuromuscular physiology and have used this model to simulate various MUNE techniques. The model allows for a quantitative analysis of candidate MUNE techniques that will hopefully contribute to consensus regarding a standard procedure for performing MUNE.
[The evaluation of costs: standards of medical care and clinical statistic groups].
Semenov, V Iu; Samorodskaia, I V
2014-01-01
The article presents the comparative analysis of techniques of evaluation of costs of hospital treatment using medical economic standards of medical care and clinical statistical groups. The technique of evaluation of costs on the basis of clinical statistical groups was developed almost fifty years ago and is largely applied in a number of countries. Nowadays, in Russia the payment for completed case of treatment on the basis of medical economic standards is the main mode of payment for medical care in hospital. It is very conditionally a Russian analogue of world-wide prevalent system of diagnostic related groups. The tariffs for these cases of treatment as opposed to clinical statistical groups are counted on basis of standards of provision of medical care approved by Minzdrav of Russia. The information derived from generalization of cases of treatment of real patients is not applied.
Standard surface-reflectance model and illuminant estimation
NASA Technical Reports Server (NTRS)
Tominaga, Shoji; Wandell, Brian A.
1989-01-01
A vector analysis technique was adopted to test the standard reflectance model. A computational model was developed to determine the components of the observed spectra and an estimate of the illuminant was obtained without using a reference white standard. The accuracy of the standard model is evaluated.
F.N. Martin; M.D. Coffey; K. Zeller; R.C. Hamelin; P. Tooley; M. Garbelotto; K.J.D. Hughes; T. Kubisiak; G.J. Bilodeau; L. Levy; C. Blomquist; P.H. Berger
2009-01-01
Given the importance of Phytophthora ramorum from a regulatory standpoint, it is imperative that molecular markers for pathogen detection are fully tested to evaluate their specificity in detection of the pathogen. In an effort to evaluate 11 reported diagnostic techniques, we assembled a standardized DNA library using accessions from the World...
USDA-ARS?s Scientific Manuscript database
Ecometric technique is a semi-quantitative scoring method used for quality control of culture media in microbiological laboratories. The technique involves inoculation with defined populations of specific culture onto solid media via a standardized chronological streaking technique, leading to ever-...
van Klink, Jeanine M M; Slaghekke, Femke; Balestriero, Marina A; Scelsa, Barbara; Introvini, Paola; Rustico, Mariangela; Faiola, Stefano; Rijken, Monique; Koopman, Hendrik M; Middeldorp, Johanna M; Oepkes, Dick; Lopriore, Enrico
2016-01-01
The preferred treatment for twin-twin transfusion syndrome is fetoscopic laser coagulation of inter-twin vascular anastomoses on the monochorionic placenta. Severe postoperative complications can occur when inter-twin vascular anastomoses remain patent including twin-anemia polycythemia sequence or recurrent twin-twin transfusion syndrome. To minimize the occurrence of residual anastomoses, a modified laser surgery technique, the Solomon technique, was developed in which the entire vascular equator is coagulated. In the Solomon randomized controlled trial (NTR1245), the Solomon technique was associated with a significant reduction in twin-anemia polycythemia sequence and recurrence of twin-twin transfusion syndrome when compared with the standard laser surgery technique. Although a significant improvement in perinatal outcome was shown after the Solomon technique, the clinical importance should also be ascertained with long-term follow-up evaluation of the surviving children. The purpose of this study was to compare the long-term neurodevelopmental outcome in surviving children with twin-twin transfusion syndrome who were included in the Solomon randomized trial and treated with either the Solomon technique or standard laser surgery technique. Routine standardized follow-up evaluation in survivors, at least 2 years after the estimated date of delivery, was performed at 2 of the 5 centers that participated in the Solomon trial: Buzzi Hospital Milan (Italy) and Leiden University Medical Center (The Netherlands). The primary outcome of this follow-up study was survival without long-term neurodevelopmental impairment at age 2 years. Neurodevelopmental impairment was defined as cerebral palsy, cognitive and/or motor development score of <85, bilateral blindness, or deafness. Cognitive and motor development was evaluated with the use of Bayley-III. All analyses per fetus, neonate, or child were conducted with the generalized estimated equation module to account for the effect that observations between co-twins are not independent. The primary outcome (survival without neurodevelopmental impairment) was detected in 95 of 141 cases (67%) in the Solomon group and in 99 of 146 cases (68%) in the standard group (P = .92). Neurodevelopmental impairment in long-term survivors who were included for follow-up evaluation was detected in 12 of 107 cases (11%) in the Solomon and in 10 of 109 cases (9%) in the standard group (P = .61). Neurodevelopmental impairment was due to cerebral palsy in 1 case (1%; spastic unilateral) in the Solomon group and in 2 cases (2%; spastic unilateral and spastic bilateral) in the standard group (P = .58). Cognitive development <85 cases was detected in 2 of 105 children (2%) in the Solomon group and in 6 of 106 children (6%) in the standard group (P = .23). Motor development <85 occurred in 8 of 103 children (8%) in the Solomon group and 3 of 104 children (3%) in the standard group (P = .23). We found no difference in survival without neurodevelopmental impairment between the Solomon and standard laser techniques. In view of the reduction of short-term complications and the absence of increased adverse long-term effects, these data support the use of the Solomon technique in the treatment of twin-twin transfusion syndrome. Copyright © 2016 Elsevier Inc. All rights reserved.
Evaluation of change detection techniques for monitoring coastal zone environments
NASA Technical Reports Server (NTRS)
Weismiller, R. A. (Principal Investigator); Kristof, S. J.; Scholz, D. K.; Anuta, P. E.; Momin, S. M.
1977-01-01
The author has identified the following significant results. Four change detection techniques were designed and implemented for evaluation: (1) post classification comparison change detection, (2) delta data change detection, (3) spectral/temporal change classification, and (4) layered spectral/temporal change classification. The post classification comparison technique reliably identified areas of change and was used as the standard for qualitatively evaluating the other three techniques. The layered spectral/temporal change classification and the delta data change detection results generally agreed with the post classification comparison technique results; however, many small areas of change were not identified. Major discrepancies existed between the post classification comparison and spectral/temporal change detection results.
Residual anastomoses in twin-twin transfusion syndrome after laser: the Solomon randomized trial.
Slaghekke, Femke; Lewi, Liesbeth; Middeldorp, Johanna M; Weingertner, Anne Sophie; Klumper, Frans J; Dekoninck, Philip; Devlieger, Roland; Lanna, Mariano M; Deprest, Jan; Favre, Romain; Oepkes, Dick; Lopriore, Enrico
2014-09-01
Residual anastomoses after fetoscopic laser surgery for twin-to-twin transfusion syndrome (TTTS) may lead to severe postoperative complications, including recurrent TTTS and twin anemia-polycythemia sequence (TAPS). A novel technique (Solomon technique) using laser coagulation of the entire vascular equator was recently investigated in a randomized controlled trial (Solomon trial) and compared with the Standard selective laser technique. The aim of this secondary analysis was to evaluate the occurrence and characteristics of residual anastomoses in placentas included in the Solomon trial. International multicenter randomized controlled trial in TTTS, randomized 1:1 ratio to either the Solomon laser technique or Standard laser technique. At time of laser, surgeons recorded whether they considered the procedure to be complete. Placental dye injection was performed after birth in the participating centers to evaluate the presence of residual anastomoses. A total of 151 placentas were included in the study. The percentage of placentas with residual anastomoses in the Solomon group and Standard group was 19% (14/74) and 34% (26/77), respectively (P = .04). The percentage of placentas with residual anastomoses in the subgroup of cases where the procedure was recorded as complete was 8/65 (12%) and 22/69 (32%) in the Solomon group and Standard group, respectively (P < .01). The Solomon laser technique reduces the risk of residual anastomoses. However, careful follow-up remains essential also after the Solomon technique, as complete dichorionization is not always achieved. Copyright © 2014 Mosby, Inc. All rights reserved.
Satué, M; Rodríguez-Calvo-de-Mora, M; Naveiras, M; Cabrerizo, J; Dapena, I; Melles, G R J
2015-08-01
To evaluate the clinical outcome of the first 450 consecutive cases after Descemet membrane endothelial keratoplasty (DMEK), as well as the effect of standardization of the technique. Comparison between 3 groups: Group I: (cases 1-125), as the extended learning curve; Group II: (cases 126-250), transition to technique standardization; Group III: (cases 251-450), surgery with standardized technique. Best corrected visual acuity, endothelial cell density, pachymetry and intra- and postoperative complications were evaluated before, and 1, 3 and 6 months after DMEK. At 6 months after surgery, 79% of eyes reached a best corrected visual acuity of≥0.8 and 43%≥1.0. Mean preoperative endothelial cell density was 2,530±220 cells/mm2 and 1,613±495 at 6 months after surgery. Mean pachymetry measured 668±92 μm and 526±46 μm pre- and (6 months) postoperatively, respectively. There were no significant differences in best corrected visual acuity, endothelial cell density and pachymetry between the 3 groups (P > .05). Graft detachment presented in 17.3% of the eyes. The detachment rate declined from 24% to 12%, and the rate of secondary surgeries from 9.6% to 3.5%, from group I to III respectively. Visual outcomes and endothelial cell density after DMEK are independent of the technique standardization. However, technique standardization may have contributed to a lower graft detachment rate and a relatively low number of secondary interventions required. As such, DMEK may become the first choice of treatment in corneal endothelial disease. Copyright © 2014 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.
Perfect Mirror Design Technology
1999-02-01
with Prof. Mario Molina, recipient of the 1995 Nobel Prize in Chemistry. The partnership, along with Aerodyne Research Inc., looked at how sulfur...Corporation is developing standards for nondestructive evaluation ( NDE ) techniques for industry use. Use of the new standards will result in improved...novel testing methodology that dramatically improves the accuracy of NDE techniques used to detect flaws. Basic Research Five years ago, the main
2004-06-01
Information Systems, Faculty of ICT, International Islamic University, Malaysia . Abstract. Several techniques for evaluating a groupware...inspection based techniques couldn’t be carried out in other parts of Pakistan where the IT industry has mushroomed in the past few years. Nevertheless...there are no set standards for using any particular technique. Evaluating a groupware interface is an evolving process and requires more investigation
Robinson, Christie A; Tsourounis, Candy
2013-03-01
To assess the literature that evaluates how variations in metered-dose inhaler (MDI) technique affect lung distribution for inhaled corticosteroids (ICSs) formulated as MDI suspensions and solutions. PubMed (up to November 2012) and Cochrane Library (up to November 2012) were searched using the terms metered-dose inhalers, HFA 134a, Asthma/*drug therapy, and inhaled corticosteroids. In addition, reference citations from publications identified were reviewed. All articles in English from the data sources that assessed MDI technique comparing total lung distribution (TLD) of MDI solutions or suspensions formulated with ICSs were included in the review. Five relevant studies were identified. Five controlled studies compared how variations in MDI technique affect TLD for ICS MDI solutions with suspensions. MDI solutions resulted in greater TLD compared with larger particle MDI suspensions. Delayed or early inspiration upon device actuation of MDI solutions resulted in less TLD than coordinated actuation, but with a 3- to 4-times greater TLD than MDI suspensions inhaled using a standard technique. A sixth study evaluated inspiratory flow rates (IFR) for small, medium, and large particles. Rapid and slow IFRs resulted in similar TLD for small particles, while far fewer particles reached the airways with medium and large particles at rapid, rather than slow, IFRs. Based on the literature evaluated, standard MDI technique should be used for ICS suspensions. ICS MDI solutions can provide a higher average TLD than larger-particle ICS suspensions using standard technique, discoordinated inspiration and medication actuation timing, or rapid and slow IFRs. ICS MDI solutions allow for a more forgiving technique, which makes them uniquely suitable options for patients with asthma who have difficultly with MDI technique.
Evaluation of cardiopulmonary resuscitation techniques in microgravity
NASA Technical Reports Server (NTRS)
Billica, Roger; Gosbee, John; Krupa, Debra T.
1991-01-01
Cardiopulmonary resuscitation (CPR) techniques were investigated in microgravity with specific application to planned medical capabilities for Space Station Freedom (SSF). A KC-135 parabolic flight test was performed with the goal of evaluating and quantifying the efficacy of different types of microgravity CPR techniques. The flight followed the standard 40 parabola profile with 20 to 25 seconds of near-zero gravity in each parabola. Three experiments were involved chosen for their clinical background, certification, and practical experience in prior KC-135 parabolic flight. The CPR evaluation was performed using a standard training mannequin (recording resusci-Annie) which was used in practice prior to the actual flight. Aboard the KC-135, the prototype medical restraint system (MRS) for the SSF Health Maintenance Facility (HMF) was used for part of the study. Standard patient and crew restraints were used for interface with the MRS. During the portion of study where CPR was performed without MRS, a set of straps for crew restraint similar to those currently employed for the Space Shuttle program were used. The entire study was recorded via still camera and video.
USDA-ARS?s Scientific Manuscript database
The ecometric technique is a semi-quantitative scoring method used in the quality control of culture media in microbiology laboratories. This technique involves inoculation with defined populations of a specific culture onto solid media via a standardized chronological streaking technique, leading ...
First uncertainty evaluation of the FoCS-2 primary frequency standard
NASA Astrophysics Data System (ADS)
Jallageas, A.; Devenoges, L.; Petersen, M.; Morel, J.; Bernier, L. G.; Schenker, D.; Thomann, P.; Südmeyer, T.
2018-06-01
We report the uncertainty evaluation of the Swiss continuous primary frequency standard FoCS-2 (Fontaine Continue Suisse). Unlike other primary frequency standards which are working with clouds of cold atoms, this fountain uses a continuous beam of cold caesium atoms bringing a series of metrological advantages and specific techniques for the evaluation of the uncertainty budget. Recent improvements of FoCS-2 have made possible the evaluation of the frequency shifts and of their uncertainties in the order of . When operating in an optimal regime a relative frequency instability of is obtained. The relative standard uncertainty reported in this article, , is strongly dominated by the statistics of the frequency measurements.
1993-06-18
the exception. In the Standardized Aquatic Microcosm and the Mixed Flask Culture (MFC) microcosms, multivariate analysis and clustering methods...rule rather than the exception. In the Standardized Aquatic Microcosm and the Mixed Flask Culture (MFC) microcosms, multivariate analysis and...experiments using two microcosm protocols. We use nonmetric clustering, a multivariate pattern recognition technique developed by Matthews and Heame (1991
[The requirements of standard and conditions of interchangeability of medical articles].
Men'shikov, V V; Lukicheva, T I
2013-11-01
The article deals with possibility to apply specific approaches under evaluation of interchangeability of medical articles for laboratory analysis. The development of standardized analytical technologies of laboratory medicine and formulation of requirements of standards addressed to manufacturers of medical articles the clinically validated requirements are to be followed. These requirements include sensitivity and specificity of techniques, accuracy and precision of research results, stability of reagents' quality in particular conditions of their transportation and storage. The validity of requirements formulated in standards and addressed to manufacturers of medical articles can be proved using reference system, which includes master forms and standard samples, reference techniques and reference laboratories. This approach is supported by data of evaluation of testing systems for measurement of level of thyrotrophic hormone, thyroid hormones and glycated hemoglobin HB A1c. The versions of testing systems can be considered as interchangeable only in case of results corresponding to the results of reference technique and comparable with them. In case of absence of functioning reference system the possibilities of the Joined committee of traceability in laboratory medicine make it possible for manufacturers of reagent sets to apply the certified reference materials under development of manufacturing of sets for large listing of analytes.
Laboratory evaluation of anti-biofilm agents for use in dental unit waterlines.
Meiller, T F; Kelley, J I; Baqui, A A; DePaola, L G
2001-01-01
Dental unit waterline biofilm has been recognized as a potential point of contamination and a risk to patients with any level of immunocompromise. Biofilm in dental unit waterlines, once established, has proven formidable to efforts in disinfection/disruption. This project compared standardized evaluation techniques by assessing the efficacy of a variety of agents that have been reported or suggested as useful in surface disinfection and/or antiseptic protocols. The zones of inhibition, minimum inhibitory/bactericidal concentrations and use-dilution with stainless steel carrier replicates tests assessed the disinfection of planktonic organisms using standardized microbial testing procedures. The disruption and/or disinfection of planktonic and biofilm organisms within naturally occurring dental unit waterlines were evaluated by culture and scanning electron microscopy. The six commercially available antimicrobial agents used to assess the techniques were bleach (sodium hypochlorite), Cavicide, glutaraldehyde, Listerine Antiseptic, Peridex and Sterilex Ultra. Comparisons between the results for each technique evaluated were determined for each product. All six agents demonstrated antimicrobial efficacy at the working concentrations designated by the manufacturers. Biofilm matrix elimination evaluated by scanning electron microscopy found virtually 0% elimination by glutaraldehyde to an estimated 90% elimination by Sterilex Ultra and bleach after one treatment. Treatment with Cavicide, Listerine Antiseptic and Peridex resulted in negligible elimination of the biofilm matrix. For comparability, the use of standardized testing techniques to evaluate a disinfection agent's efficacy against dental unit waterline contamination is essential. This project demonstrates a model system for evaluating disinfection agents potentially useful in the management of dental unit waterline biofilm, and should assist in educating the dental clinician in the appraisal of existing and future product claims.
Langley Research Center Standard for the Evaluation of Socket Welds
NASA Technical Reports Server (NTRS)
Berry, R. F., Jr.
1985-01-01
A specification utilized for the nondestructive evaluation of socket type pipe joints at Langley Research Center (LaRC) is discussed. The scope of hardware shall include, but is not limited to, all common pipe fittings: tees, elbows, couplings, caps, and so forth, socket type flanges, unions, and valves. In addition, the exterior weld of slip on flanges shall be inspected using this specification. At the discretion of the design engineer, standard practice engineer, Fracture Mechanics Engineering Section, Pressure Systems Committee, or other authority, four nondestructive evaluation techniques may be utilized exclusively, or in combination, to inspect socket type welds. These techniques are visual, radiographic, magnetic particle, and dye penetrant. Under special circumstances, other techniques (such as eddy current or ultrasonics) may be required and their application shall be guided by the appropriate sections of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code (B&PVC).
Morphological and functional evaluation of chronic pancreatitis with magnetic resonance imaging
Hansen, Tine Maria; Nilsson, Matias; Gram, Mikkel; Frøkjær, Jens Brøndum
2013-01-01
Magnetic resonance imaging (MRI) techniques for assessment of morphology and function of the pancreas have been improved dramatically the recent years and MRI is very often used in diagnosing and follow-up of chronic pancreatitis (CP) patients. Standard MRI including fat-suppressed T1-weighted and T2-weighted imaging techniques reveal decreased signal and glandular atrophy of the pancreas in CP. In contrast-enhanced MRI of the pancreas in CP the pancreatic signal is usually reduced and delayed due to decreased perfusion as a result of chronic inflammation and fibrosis. Thus, morphological changes of the ductal system can be assessed by magnetic resonance cholangiopancreatography (MRCP). Furthermore, secretin-stimulated MRCP is a valuable technique to evaluate side branch pathology and the exocrine function of the pancreas and diffusion weighted imaging can be used to quantify both parenchymal fibrotic changes and the exocrine function of the pancreas. These standard and advanced MRI techniques are supplementary techniques to reveal morphological and functional changes of the pancreas in CP. Recently, spectroscopy has been used for assessment of metabolite concentrations in-vivo in different tissues and may have the potential to offer better tissue characterization of the pancreas. Hence, the purpose of the present review is to provide an update on standard and advanced MRI techniques of the pancreas in CP. PMID:24259954
Optimisation of radiation dose and image quality in mobile neonatal chest radiography.
Hinojos-Armendáriz, V I; Mejía-Rosales, S J; Franco-Cabrera, M C
2018-05-01
To optimise the radiation dose and image quality for chest radiography in the neonatal intensive care unit (NICU) by increasing the mean beam energy. Two techniques for the acquisition of NICU AP chest X-ray images were compared for image quality and radiation dose. 73 images were acquired using a standard technique (56 kV, 3.2 mAs and no additional filtration) and 90 images with a new technique (62 kV, 2 mAs and 2 mm Al filtration). The entrance surface air kerma (ESAK) was measured using a phantom and compared between the techniques and against established diagnostic reference levels (DRL). Images were evaluated using seven image quality criteria independently by three radiologists. Images quality and radiation dose were compared statistically between the standard and new techniques. The maximum ESAK for the new technique was 40.20 μGy, 43.7% of the ESAK of the standard technique. Statistical evaluation demonstrated no significant differences in image quality between the two acquisition techniques. Based on the techniques and acquisition factors investigated within this study, it is possible to lower the radiation dose without any significant effects on image quality by adding filtration (2 mm Al) and increasing the tube potential. Such steps are relatively simple to undertake and as such, other departments should consider testing and implementing this dose reduction strategy within clinical practice where appropriate. Copyright © 2017 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.
Ultrasound imaging of the anal sphincter complex: a review
Abdool, Z; Sultan, A H; Thakar, R
2012-01-01
Endoanal ultrasound is now regarded as the gold standard for evaluating anal sphincter pathology in the investigation of anal incontinence. The advent of three-dimensional ultrasound has further improved our understanding of the two-dimensional technique. Endoanal ultrasound requires specialised equipment and its relative invasiveness has prompted clinicians to explore alternative imaging techniques. Transvaginal and transperineal ultrasound have been recently evaluated as alternative imaging modalities. However, the need for technique standardisation, validation and reporting is of paramount importance. We conducted a MEDLINE search (1950 to February 2010) and critically reviewed studies using the three imaging techniques in evaluating anal sphincter integrity. PMID:22374273
Kim, Pyeong Hwa; Song, Ho-Young; Park, Jung-Hoon; Zhou, Wei-Zhong; Na, Han Kyu; Cho, Young Chul; Jun, Eun Jung; Kim, Jun Ki; Kim, Guk Bae
2017-03-01
To evaluate clinical outcomes of fluoroscopic removal of retrievable self-expandable metal stents (SEMSs) for malignant oesophageal strictures, to compare clinical outcomes of three different removal techniques, and to identify predictive factors of successful removal by the standard technique (primary technical success). A total of 137 stents were removed from 128 patients with malignant oesophageal strictures. Primary overall technical success and removal-related complications were evaluated. Logistic regression models were constructed to identify predictive factors of primary technical success. Primary technical success rate was 78.8 % (108/137). Complications occurred in six (4.4 %) cases. Stent location in the upper oesophagus (P=0.004), stricture length over 8 cm (P=0.030), and proximal granulation tissue (P<0.001) were negative predictive factors of primary technical success. If granulation tissue was present at the proximal end, eversion technique was more frequently required (P=0.002). Fluoroscopic removal of retrievable SEMSs for malignant oesophageal strictures using three different removal techniques appeared to be safe and easy. The standard technique is safe and effective in the majority of patients. The presence of proximal granulation tissue, stent location in the upper oesophagus, and stricture length over 8 cm were negative predictive factors for primary technical success by standard extraction and may require a modified removal technique. • Fluoroscopic retrievable SEMS removal is safe and effective. • Standard removal technique by traction is effective in the majority of patients. • Three negative predictive factors of primary technical success were identified. • Caution should be exercised during the removal in those situations. • Eversion technique is effective in cases of proximal granulation tissue.
Performance evaluation of the atmospheric phase of aeromaneuvering orbital transfer vehicles
NASA Technical Reports Server (NTRS)
Powell, R. W.; Stone, H. W.; Naftel, J. C.
1984-01-01
Studies are underway to design reusable orbital transfer vehicles that would be used to transfer payloads from low-earth orbit to higher orbits and return. One promising concept is to use an atmospheric pass on the return leg to reduce the amount of fuel for the mission. This paper discusses a six-degree-of-freedom simulation analysis for two configurations, a low-lift-to-drag ratio configuration and a medium-lift-to-drag ratio configuration using both a predictive guidance technique and an adaptive guidance technique. Both guidance schemes were evaluated using the 1962 standard atmosphere and three atmospheres that had been derived from three entries of the Space Shuttle. The predictive technique requires less reaction control system activity for both configurations, but because of the limited number of updates and because each update used the 1962 standard atmosphere, the adaptive technique produces more accurate exit conditions.
Software component quality evaluation
NASA Technical Reports Server (NTRS)
Clough, A. J.
1991-01-01
The paper describes a software inspection process that can be used to evaluate the quality of software components. Quality criteria, process application, independent testing of the process and proposed associated tool support are covered. Early results indicate that this technique is well suited for assessing software component quality in a standardized fashion. With automated machine assistance to facilitate both the evaluation and selection of software components, such a technique should promote effective reuse of software components.
F.N. Martin; M. Coffey; R. Hamelin; P. Tooley; M. Garbelotto; K. Hughes; T. Kubisiak
2008-01-01
A number of molecular diagnostic procedures for detection of Phytophthora ramorum have been reported in the literature. In an effort to evaluate the specificity of 10 of these techniques a standardized DNA library for 317 isolates was assembled that included 60 described species as well as 22 taxonomically unclassified isolates. These were sent blind...
Deploying an Intelligent Pairing Assistant for Air Operation Centers
2016-06-23
primary contributions of this case study are applying artificial intelligence techniques to a novel domain and discussing the software evaluation...their standard workflows. The primary contributions of this case study are applying artificial intelligence techniques to a novel domain and...users for more efficient and accurate pairing? Participants Participants in the evaluation consisted of three SMEs employed at Intelligent Software
NASA Technical Reports Server (NTRS)
Billica, Roger; Krupa, Debra T.; Stonestreet, Robert; Kizzee, Victor D.
1991-01-01
The purpose is to investigate and demonstrate equipment and techniques proposed for minor surgery on Space Station Freedom (SSF). The objectives are: (1) to test and evaluate methods of surgical instrument packaging and deployment; (2) to test and evaluate methods of surgical site preparation and draping; (3) to evaluate techniques of sterile procedure and maintaining sterile field; (4) to evaluate methods of trash management during medical/surgical procedures; and (4) to gain experience in techniques for performing surgery in microgravity. A KC-135 parabolic flight test was performed on March 30, 1990 with the goal of investigating and demonstrating surgical equipment and techniques under consideration for use on SSF. The flight followed the standard 40 parabola profile with 20 to 25 seconds of near-zero gravity in each parabola.
NASA Technical Reports Server (NTRS)
Kurtenbach, F. J.
1979-01-01
The technique which relies on afterburner duct pressure measurements and empirical corrections to an ideal one dimensional flow analysis to determine thrust is presented. A comparison of the calculated and facility measured thrust values is reported. The simplified model with the engine manufacturer's gas generator model are compared. The evaluation was conducted over a range of Mach numbers from 0.80 to 2.00 and at altitudes from 4020 meters to 15,240 meters. The effects of variations in inlet total temperature from standard day conditions were explored. Engine conditions were varied from those normally scheduled for flight. The technique was found to be accurate to a twice standard deviation of 2.89 percent, with accuracy a strong function of afterburner duct pressure difference.
Statistical Evaluation of Time Series Analysis Techniques
NASA Technical Reports Server (NTRS)
Benignus, V. A.
1973-01-01
The performance of a modified version of NASA's multivariate spectrum analysis program is discussed. A multiple regression model was used to make the revisions. Performance improvements were documented and compared to the standard fast Fourier transform by Monte Carlo techniques.
Algin, Oktay
2018-05-21
Phase-contrast cine magnetic resonance imaging (PC-MRI) is a widely used technique for determination of possible communication of arachnoid cysts (ACs). Three-dimensional (3D) sampling perfection with application-optimized contrasts using different flip-angle evolutions (3D-SPACE) technique is a relatively new method for 3D isotropic scanning of the entire cranium within a short time. In this research, the usage of the 3D-SPACE technique in differentiation of communicating or noncommunicating type ACs was evaluated. Thirty-five ACs in 34 patients were retrospectively examined. The 3D-SPACE, PC-MRI, and contrast material-enhanced cisternography (if present) images of the patients were analyzed. Each cyst was described according to cyst size/location, third ventricle diameter, Evans index, and presence of hydrocephalus. Communication was defined as absent (score 0), suspected (score 1), or present (score 2) on each sequence. Results of PC-MRI or cisternography (if available) examinations were used as criterion standard techniques to categorize all cysts as communicating or noncommunicating type. The results of 3D-SPACE were compared with criterion standard techniques. The comparisons between groups were performed using Mann-Whitney and Fisher exact tests. For demonstration of communication status of the cysts, criterion standard test results and 3D-SPACE findings were almost in perfect harmony (κ[95% confidence interval: 0.94]; P < 0.001). When evaluating the communicative properties, 3D-SPACE findings correlated with other final results at a rate of 97%. There is a positive correlation with third ventricular diameters and Evans index for all patients (r = 0.77, P < 0.001). For other analyzed variables, there is no significant difference or correlation between the groups. The 3D-SPACE technique is an easy, useful, and noninvasive alternative for the evaluation of morphology, topographical relationships, and communication status of ACs.
Automated standardization technique for an inductively-coupled plasma emission spectrometer
Garbarino, John R.; Taylor, Howard E.
1982-01-01
The manifold assembly subsystem described permits real-time computer-controlled standardization and quality control of a commercial inductively-coupled plasma atomic emission spectrometer. The manifold assembly consists of a branch-structured glass manifold, a series of microcomputer-controlled solenoid valves, and a reservoir for each standard. Automated standardization involves selective actuation of each solenoid valve that permits a specific mixed standard solution to be pumped to the nebulizer of the spectrometer. Quality control is based on the evaluation of results obtained for a mixed standard containing 17 analytes, that is measured periodically with unknown samples. An inaccurate standard evaluation triggers restandardization of the instrument according to a predetermined protocol. Interaction of the computer-controlled manifold assembly hardware with the spectrometer system is outlined. Evaluation of the automated standardization system with respect to reliability, simplicity, flexibility, and efficiency is compared to the manual procedure. ?? 1982.
STANDARDIZATION AND VALIDATION OF MICROBIOLOGICAL METHODS FOR EXAMINATION OF BIOSOLIDS
The objective of this presentation is to discuss pathogens of concern in biosolids, the analytical techniques used to evaluate microorganisms in biosolids, and to discuss standardization and validation of analytical protocols for microbes within a complex matrix. Implications of ...
MICROORGANISMS IN BIOSOLIDS: ANALYTICAL METHODS DEVELOPMENT, STANDARDIZATION, AND VALIDATION
The objective of this presentation is to discuss pathogens of concern in biosolids, the analytical techniques used to evaluate microorganisms in biosolids, and to discuss standardization and validation of analytical protocols for microbes within such a complex matrix. Implicatio...
Standardized Patient Teaching: A Modality for Teaching Interviewing Skills.
ERIC Educational Resources Information Center
Konkle-Parker, Deborah J.; Cramer, Carl K.; Hamill, Cheryl
2002-01-01
Health care providers were trained using standardized patients (individuals acting as patients) to conduct AIDS risk assessment and posttest counseling. Evaluations involving over 500 participants determined it was an effective technique; however, participants in group formats experienced discomfort. (SK)
1982-09-30
not changed because they are not subject to a careful evaluation. The solution The four job aids contained in this manual provide specific techniques...lesson plans tions. " training design, or * testing NOTICE This manual has been developed using the standards of the Information MappingO writing service...Information Mapping, Inc. S NOTICE This manual has been developed using the standards of the Information MappingS writing service. Infornation Mapping
Hyperhidrosis: review of recent advances and new therapeutic options for primary hyperhidrosis.
Brown, Ashley L; Gordon, Jennifer; Hill, Samantha
2014-08-01
Primary focal hyperhidrosis is a common condition that negatively impacts quality of life for many pediatric patients and can be challenging to treat. Standard treatments for hyperhidrosis can be used with success in many patients, and newer therapies and techniques offer options that have demonstrated efficacy and safety. This review highlights standard therapies for primary focal hyperhidrosis as well as the most recent technique advancements and alternative treatment options. The standard approach to treating primary focal hyperhidrosis remains initiation of topical preparations, followed by advancement to systemic medications, local administration of medication and/or surgical procedures. Recent studies focus on enhancing tolerability of topical preparations as well as evaluating the efficacy of neuromodulator injections, oral anticholinergic medications and laser therapy. Microwave technology has also been introduced for the treatment of focal hyperhidrosis with promising results. Many therapies exist for hyperhidrosis, and each treatment plan must be evaluated on a patient-by-patient basis. Advances in standard therapies and emergence of new treatment techniques are the main emphases of current published literature on hyperhidrosis. This article presents recent therapeutic options as well as updates on more established strategies to help practitioners treat this challenging condition.
Cross-platform comparison of nucleic acid hybridization: toward quantitative reference standards.
Halvorsen, Ken; Agris, Paul F
2014-11-15
Measuring interactions between biological molecules is vitally important to both basic and applied research as well as development of pharmaceuticals. Although a wide and growing range of techniques is available to measure various kinetic and thermodynamic properties of interacting biomolecules, it can be difficult to compare data across techniques of different laboratories and personnel or even across different instruments using the same technique. Here we evaluate relevant biological interactions based on complementary DNA and RNA oligonucleotides that could be used as reference standards for many experimental systems. We measured thermodynamics of duplex formation using isothermal titration calorimetry, differential scanning calorimetry, and ultraviolet-visible (UV-vis) monitored denaturation/renaturation. These standards can be used to validate results, compare data from disparate techniques, act as a teaching tool for laboratory classes, or potentially to calibrate instruments. The RNA and DNA standards have many attractive features, including low cost, high purity, easily measurable concentrations, and minimal handling concerns, making them ideal for use as a reference material. Copyright © 2014 Elsevier Inc. All rights reserved.
Microwave cryogenic thermal-noise standards
NASA Technical Reports Server (NTRS)
Stelzried, C. T.
1971-01-01
Field operational waveguide noise standard with nominal noise temperature of 78.09 plus/minus 0.12 deg K is calibrated more precisely than before. Calibration technique applies to various disciplines such as microwave radiometry, antenna temperature and loss measurement, and low-noise amplifier performance evaluation.
NASA Astrophysics Data System (ADS)
Sallaberry, Fabienne; Fernández-García, Aránzazu; Lüpfert, Eckhard; Morales, Angel; Vicente, Gema San; Sutter, Florian
2017-06-01
Precise knowledge of the optical properties of the components used in the solar field of concentrating solar thermal power plants is primordial to ensure their optimum power production. Those properties are measured and evaluated by different techniques and equipment, in laboratory conditions and/or in the field. Standards for such measurements and international consensus for the appropriate techniques are in preparation. The reference materials used as a standard for the calibration of the equipment are under discussion. This paper summarizes current testing methodologies and guidelines for the characterization of optical properties of solar mirrors and absorbers.
Mohammed, Nazmi A; Solaiman, Mohammad; Aly, Moustafa H
2014-10-10
In this work, various dispersion compensation methods are designed and evaluated to search for a cost-effective technique with remarkable dispersion compensation and a good pulse shape. The techniques consist of different chirp functions applied to a tanh fiber Bragg grating (FBG), a dispersion compensation fiber (DCF), and a DCF merged with an optimized linearly chirped tanh FBG (joint technique). The techniques are evaluated using a standard 10 Gb/s optical link over a 100 km long haul. The linear chirp function is the most appropriate choice of chirping function, with a pulse width reduction percentage (PWRP) of 75.15%, lower price, and poor pulse shape. The DCF yields an enhanced PWRP of 93.34% with a better pulse quality; however, it is the most costly of the evaluated techniques. Finally, the joint technique achieved the optimum PWRP (96.36%) among all the evaluated techniques and exhibited a remarkable pulse shape; it is less costly than the DCF, but more expensive than the chirped tanh FBG.
Establishment of metrological traceability in porosity measurements by x-ray computed tomography
NASA Astrophysics Data System (ADS)
Hermanek, Petr; Carmignato, Simone
2017-09-01
Internal porosity is an inherent phenomenon to many manufacturing processes, such as casting, additive manufacturing, and others. Since these defects cannot be completely avoided by improving production processes, it is important to have a reliable method to detect and evaluate them accurately. The accurate evaluation becomes even more important concerning current industrial trends to minimize size and weight of products on one side, and enhance their complexity and performance on the other. X-ray computed tomography (CT) has emerged as a promising instrument for holistic porosity measurements offering several advantages over equivalent methods already established in the detection of internal defects. The main shortcomings of the conventional techniques pertain to too general information about total porosity content (e.g. Archimedes method) or the destructive way of testing (e.g. microscopy of cross-sections). On the contrary, CT is a nondestructive technique providing complete information about size, shape and distribution of internal porosity. However, due to the lack of international standards and the fact that it is relatively a new measurement technique, CT as a measurement technology has not yet reached maturity. This study proposes a procedure for the establishment of measurement traceability in porosity measurements by CT including the necessary evaluation of measurement uncertainty. The traceability transfer is carried out through a novel reference standard calibrated by optical and tactile coordinate measuring systems. The measurement uncertainty is calculated following international standards and guidelines. In addition, the accuracy of porosity measurements by CT with the associated measurement uncertainty is evaluated using the reference standard.
CT angiography of the renal arteries and veins: normal anatomy and variants.
Hazırolan, Tuncay; Öz, Meryem; Türkbey, Barış; Karaosmanoğlu, Ali Devrim; Oğuz, Berna Sayan; Canyiğit, Murat
2011-03-01
Conventional angiography has long been regarded as gold standard imaging modality for evaluation of the renal vasculature. Introduction of multidetector computed tomography (MDCT) angiography had a groundbreaking impact on evaluation of the renal vessels and is gradually replacing conventional angiography as standard imaging. Herein, we review and illustrate the normal and variant anatomy of renal vessels with special emphasis on imaging protocols and reconstruction techniques in MDCT.
Nguyen, Phung Anh; Yang, Hsuan-Chia; Xu, Rong; Li, Yu-Chuan Jack
2018-01-01
Traditional Chinese Medicine utilization has rapidly increased worldwide. However, there is limited database provides the information of TCM herbs and diseases. The study aims to identify and evaluate the meaningful associations between TCM herbs and breast cancer by using the association rule mining (ARM) techniques. We employed the ARM techniques for 19.9 million TCM prescriptions by using Taiwan National Health Insurance claim database from 1999 to 2013. 364 TCM herbs-breast cancer associations were derived from those prescriptions and were then filtered by their support of 20. Resulting of 296 associations were evaluated by comparing to a gold-standard that was curated information from Chinese-Wikipedia with the following terms, cancer, tumor, malignant. All 14 TCM herbs-breast cancer associations with their confidence of 1% were valid when compared to gold-standard. For other confidences, the statistical results showed consistently with high precisions. We thus succeed to identify the TCM herbs-breast cancer associations with useful techniques.
Nursing concerns and hospital product sterilization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rock, R.B. Jr.; Anderson, N.A.
Nurses and other health care professionals must be aware of the rationale and methodology for in-hospital health care product standardization, including consideration of the hospital standardization committee composition, pilot-study prerequisites, and general evaluation criteria. They must be familiar with the techniques of product sterilization, their effectiveness, and the materials required to maintain sterile product shelf-life until a product is used. Hospital standardization committees can assist in the product-use decisionmaking process. Product evaluation criteria should include considerations pertaining to cost, quality, service, and comparison to similar products.
Muscle activity characterization by laser Doppler Myography
NASA Astrophysics Data System (ADS)
Scalise, Lorenzo; Casaccia, Sara; Marchionni, Paolo; Ercoli, Ilaria; Primo Tomasini, Enrico
2013-09-01
Electromiography (EMG) is the gold-standard technique used for the evaluation of muscle activity. This technique is used in biomechanics, sport medicine, neurology and rehabilitation therapy and it provides the electrical activity produced by skeletal muscles. Among the parameters measured with EMG, two very important quantities are: signal amplitude and duration of muscle contraction, muscle fatigue and maximum muscle power. Recently, a new measurement procedure, named Laser Doppler Myography (LDMi), for the non contact assessment of muscle activity has been proposed to measure the vibro-mechanical behaviour of the muscle. The aim of this study is to present the LDMi technique and to evaluate its capacity to measure some characteristic features proper of the muscle. In this paper LDMi is compared with standard superficial EMG (sEMG) requiring the application of sensors on the skin of each patient. sEMG and LDMi signals have been simultaneously acquired and processed to test correlations. Three parameters has been analyzed to compare these techniques: Muscle activation timing, signal amplitude and muscle fatigue. LDMi appears to be a reliable and promising measurement technique allowing the measurements without contact with the patient skin.
Wide Panel Testing Technique for Evaluating Repair Weld Strengths
NASA Technical Reports Server (NTRS)
Rogers, Patrick R.; Bynum, Julian E.; Shah, Sandeep R.
1998-01-01
This paper describes a new tensile testing technique for evaluating the overall effect of a repair weld on the strength of a welded joint. Previously, repair weld strengths have been evaluated using one-inch width tensile specimens, but this technique does not capture all of the effects that result from a repair. The new technique involves testing of "wide panel" tensile specimens which contain the full length of a repair weld within a longer initial weld, allowing the specimen to capture the combined effects of residual stresses, local strength degradation, and load redistribution around a repair. The development of strains in the repair area of standard aluminum alloy specimens and new high-performance aluminum-lithium alloy specimens was observed and evaluated using photoelastic material. The results of this evaluation show an increased sensitivity to repair welding residual stresses in the aluminum-lithium alloy specimens.
Berger, Cezar Augusto Sarraf; Freitas, Renato da Silva; Malafaia, Osvaldo; Pinto, José Simão de Paula; Macedo Filho, Evaldo Dacheux; Mocellin, Marcos; Fagundes, Marina Serrato Coelho
2014-01-01
Introduction The knowledge and study of surgical techniques and anthropometric measurements of the nose make possible a qualitative and quantitative analysis of surgical results. Objective Study the main technique used in rhinoplasty on Caucasian noses and compare preoperative and postoperative anthropometric measurements of the nose. Methods A prospective study with 170 patients was performed at a private hospital. Data were collected using the Electronic System Integrated of Protocols software (Sistema Integrado de Protocolos Eletrônicos, SINPE©). The surgical techniques used in the nasal dorsum and tip were evaluated. Preoperative and 12-month follow-up photos as well as the measurements compared with the ideal aesthetic standard of a Caucasian nose were analyzed objectively. Student t test and standard deviation test were applied. Results There was a predominance of endonasal access (94.4%). The most common dorsum technique was hump removal (33.33%), and the predominance of sutures (24.76%) was observed on the nasal tip, with the lateral intercrural the most frequent (32.39%). Comparison between preoperative and postoperative photos found statistically significant alterations on the anthropometric measurements of the noses. Conclusion The main surgical techniques on Caucasian noses were evaluated, and a great variety was found. The evaluation of anthropometric measurements of the nose proved the efficiency of the performed procedures. PMID:25992149
Novel permutation measures for image encryption algorithms
NASA Astrophysics Data System (ADS)
Abd-El-Hafiz, Salwa K.; AbdElHaleem, Sherif H.; Radwan, Ahmed G.
2016-10-01
This paper proposes two measures for the evaluation of permutation techniques used in image encryption. First, a general mathematical framework for describing the permutation phase used in image encryption is presented. Using this framework, six different permutation techniques, based on chaotic and non-chaotic generators, are described. The two new measures are, then, introduced to evaluate the effectiveness of permutation techniques. These measures are (1) Percentage of Adjacent Pixels Count (PAPC) and (2) Distance Between Adjacent Pixels (DBAP). The proposed measures are used to evaluate and compare the six permutation techniques in different scenarios. The permutation techniques are applied on several standard images and the resulting scrambled images are analyzed. Moreover, the new measures are used to compare the permutation algorithms on different matrix sizes irrespective of the actual parameters used in each algorithm. The analysis results show that the proposed measures are good indicators of the effectiveness of the permutation technique.
Evaluation of Subsurface Engineered Barriers at Waste Sites
1998-08-01
28 3-4 MATRIX FOR EVALUATING BARRIER CQA/CQC AGAINST ACCEPTABLE INDSUTRY PRACTICES...STANDARDS................................................................. 66 4-2 MATRIX FOR EVALUATING CAP AGAINST ACCEPTABLE INDSUTRY PRACTICES...stated previously, the most widely used technique for containment is the soil-bentonite slurry wall. It is typically the most economical , utilizes low
Methods for assessing the quality of mammalian embryos: How far we are from the gold standard?
Rocha, José C; Passalia, Felipe; Matos, Felipe D; Maserati, Marc P; Alves, Mayra F; Almeida, Tamie G de; Cardoso, Bruna L; Basso, Andrea C; Nogueira, Marcelo F G
2016-08-01
Morphological embryo classification is of great importance for many laboratory techniques, from basic research to the ones applied to assisted reproductive technology. However, the standard classification method for both human and cattle embryos, is based on quality parameters that reflect the overall morphological quality of the embryo in cattle, or the quality of the individual embryonic structures, more relevant in human embryo classification. This assessment method is biased by the subjectivity of the evaluator and even though several guidelines exist to standardize the classification, it is not a method capable of giving reliable and trustworthy results. Latest approaches for the improvement of quality assessment include the use of data from cellular metabolism, a new morphological grading system, development kinetics and cleavage symmetry, embryo cell biopsy followed by pre-implantation genetic diagnosis, zona pellucida birefringence, ion release by the embryo cells and so forth. Nowadays there exists a great need for evaluation methods that are practical and non-invasive while being accurate and objective. A method along these lines would be of great importance to embryo evaluation by embryologists, clinicians and other professionals who work with assisted reproductive technology. Several techniques shows promising results in this sense, one being the use of digital images of the embryo as basis for features extraction and classification by means of artificial intelligence techniques (as genetic algorithms and artificial neural networks). This process has the potential to become an accurate and objective standard for embryo quality assessment.
Methods for assessing the quality of mammalian embryos: How far we are from the gold standard?
Rocha, José C.; Passalia, Felipe; Matos, Felipe D.; Maserati Jr, Marc P.; Alves, Mayra F.; de Almeida, Tamie G.; Cardoso, Bruna L.; Basso, Andrea C.; Nogueira, Marcelo F. G.
2016-01-01
Morphological embryo classification is of great importance for many laboratory techniques, from basic research to the ones applied to assisted reproductive technology. However, the standard classification method for both human and cattle embryos, is based on quality parameters that reflect the overall morphological quality of the embryo in cattle, or the quality of the individual embryonic structures, more relevant in human embryo classification. This assessment method is biased by the subjectivity of the evaluator and even though several guidelines exist to standardize the classification, it is not a method capable of giving reliable and trustworthy results. Latest approaches for the improvement of quality assessment include the use of data from cellular metabolism, a new morphological grading system, development kinetics and cleavage symmetry, embryo cell biopsy followed by pre-implantation genetic diagnosis, zona pellucida birefringence, ion release by the embryo cells and so forth. Nowadays there exists a great need for evaluation methods that are practical and non-invasive while being accurate and objective. A method along these lines would be of great importance to embryo evaluation by embryologists, clinicians and other professionals who work with assisted reproductive technology. Several techniques shows promising results in this sense, one being the use of digital images of the embryo as basis for features extraction and classification by means of artificial intelligence techniques (as genetic algorithms and artificial neural networks). This process has the potential to become an accurate and objective standard for embryo quality assessment. PMID:27584609
Somerson, Jeremy S; Rowley, David; Kennedy, Chad; Buttacavoli, Frank; Agarwal, Animesh
2014-07-01
To compare the time required for proximal locking screw placement between a standard freehand technique and the navigated technique, and to quantify the reduction in ionizing radiation exposure. A fresh frozen cadaver model was used for 48 proximal interlocking screw procedures. Each procedure consisted of insertion of 2 anteroposterior locking screws. Standard fluoroscopic technique was used for 24 procedures, and an electromagnetic navigation system was used for the remaining 24 procedures. Procedure duration was recorded using an electronic timer and radiation doses were documented. Mean total insertion time for both proximal interlocking screws was 405 ± 165.7 seconds with the freehand technique and 311 ± 78.3 seconds in the navigation group (P = 0.002). All procedures resulted in successful locking screw placement. Mean ionizing radiation exposure time for proximal locking was 29.5 ± 12.8 seconds. Proximal locking screw insertion using the navigation technique evaluated in this work was significantly faster than the standard fluoroscopic method. The navigated technique is effective and has the potential to prevent ionizing radiation exposure.
Incorporating principal component analysis into air quality model evaluation
The efficacy of standard air quality model evaluation techniques is becoming compromised as the simulation periods continue to lengthen in response to ever increasing computing capacity. Accordingly, the purpose of this paper is to demonstrate a statistical approach called Princi...
Park, Jin Ha; Lee, Jong Seok; Nam, Sang Beom; Ju, Jin Wu
2016-01-01
Purpose Supraglottic airway devices have been widely utilized as an alternative to tracheal intubation in various clinical situations. The rotation technique has been proposed to improve the insertion success rate of supraglottic airways. However, the clinical efficacy of this technique remains uncertain as previous results have been inconsistent, depending on the variable evaluated. Materials and Methods We systematically searched PubMed, Embase, and the Cochrane Central Register of Controlled Trials in April 2015 for randomized controlled trials that compared the rotation and standard techniques for inserting supraglottic airways. Results Thirteen randomized controlled trials (1505 patients, 753 with the rotation technique) were included. The success rate at the first attempt was significantly higher with the rotation technique than with the standard technique [relative risk (RR): 1.13; 95% confidence interval (CI): 1.05 to 1.23; p=0.002]. The rotation technique provided significantly higher overall success rates (RR: 1.06; 95% CI: 1.04 to 1.09; p<0.001). Device insertion was completed faster with the rotation technique (mean difference: -4.6 seconds; 95% CI: -7.37 to -1.74; p=0.002). The incidence of blood staining on the removed device (RR: 0.36; 95% CI: 0.27 to 0.47; p<0.001) was significantly lower with the rotation technique. Conclusion The rotation technique provided higher first-attempt and overall success rates, faster insertion, and a lower incidence of blood on the removed device, reflecting less mucosal trauma. Thus, it may be considered as an alternative to the standard technique when predicting or encountering difficulty in inserting supraglottic airways. PMID:27189296
Binary-mask generation for diffractive optical elements using microcomputers.
O'Shea, D C; Beletic, J W; Poutous, M
1993-05-10
A new technique for generation of binary masks for the fabrication of diffractive optical elements is investigated. This technique, which uses commercially available desktop-publishing hardware and software in conjunction with a standard photoreduction camera, is much faster and less expensive thanhe conventional methods. The short turnaround time and low cost should give researchers a much greater degree of flexibility in the field of binary optics and enable wider application of diffractive-optics technology. Techniques for generating optical elements by using standard software packages that produce PostScript output are described. An evaluation of the dimensional fidelity of the mask reproduction from design to its realization in photoresist is presented.
Sun, Zong-ke; Wu, Rong; Ding, Pei; Xue, Jin-Rong
2006-07-01
To compare between rapid detection method of enzyme substrate technique and multiple-tube fermentation technique in water coliform bacteria detection. Using inoculated and real water samples to compare the equivalence and false positive rate between two methods. Results demonstrate that enzyme substrate technique shows equivalence with multiple-tube fermentation technique (P = 0.059), false positive rate between the two methods has no statistical difference. It is suggested that enzyme substrate technique can be used as a standard method for water microbiological safety evaluation.
Monitoring and Management of a Sensitive Resource: A Landscape-level Approach with Amphibians
2001-03-01
Results show that each technique is effective for a portion of the amphibian community and that the use of multiple techniques is essential to any...combinations of species. These results show that multiple techniques are needed for a full assessment of amphibian populations and communities at...against which future assessments of amphibian populations and communities on each installation can be evaluated. The standardized techniques used in FY
Freeman, Karoline; Tsertsvadze, Alexander; Taylor-Phillips, Sian; McCarthy, Noel; Mistry, Hema; Manuel, Rohini; Mason, James
2017-01-01
Multiplex gastrointestinal pathogen panel (GPP) tests simultaneously identify bacterial, viral and parasitic pathogens from the stool samples of patients with suspected infectious gastroenteritis presenting in hospital or the community. We undertook a systematic review to compare the accuracy of GPP tests with standard microbiology techniques. Searches in Medline, Embase, Web of Science and the Cochrane library were undertaken from inception to January 2016. Eligible studies compared GPP tests with standard microbiology techniques in patients with suspected gastroenteritis. Quality assessment of included studies used tailored QUADAS-2. In the absence of a reference standard we analysed test performance taking GPP tests and standard microbiology techniques in turn as the benchmark test, using random effects meta-analysis of proportions. No study provided an adequate reference standard with which to compare the test accuracy of GPP and conventional tests. Ten studies informed a meta-analysis of positive and negative agreement. Positive agreement across all pathogens was 0.93 (95% CI 0.90 to 0.96) when conventional methods were the benchmark and 0.68 (95% CI: 0.58 to 0.77) when GPP provided the benchmark. Negative agreement was high in both instances due to the high proportion of negative cases. GPP testing produced a greater number of pathogen-positive findings than conventional testing. It is unclear whether these additional 'positives' are clinically important. GPP testing has the potential to simplify testing and accelerate reporting when compared to conventional microbiology methods. However the impact of GPP testing upon the management, treatment and outcome of patients is poorly understood and further studies are needed to evaluate the health economic impact of GPP testing compared with standard methods. The review protocol is registered with PROSPERO as CRD42016033320.
Masala, Salvatore; Schillaci, Orazio; Bartolucci, Alberto D; Calabria, Ferdinando; Mammucari, Matteo; Simonetti, Giovanni
2011-02-01
Various therapy modalities have been proposed as standard treatments in management of bone metastases. Radiation therapy remains the standard of care for patients with localized bone pain, but up to 30% of them do not experience notable pain relief. Percutaneous cryoablation is a minimally invasive technique that induces necrosis by alternately freezing and thawing a target tissue. This technique is successfully used to treat a variety of malignant and benign diseases in different sites. (18)F-FDG positron emission tomography/computed tomography ((18)F-FDG PET/CT) is a single technique of imaging that provides in a "single step" both morphological and metabolic features of neoplastic lesions of the bone. The aim of this study was to evaluate the efficacy of the cryosurgical technique on secondary musculoskeletal masses according to semi-quantitative PET analysis and clinical-test evaluation with the visual analogue scale (VAS). We enrolled 20 patients with painful bone lesions (score pain that exceeded 4 on the VAS) that were non-responsive to treatment; one lesion per patient was treated. All patients underwent a PET-CT evaluation before and 8 weeks after cryotherapy; maximum standardized uptake value (SUV(max)) was measured before and after treatment for metabolic assessment of response to therapy. After treatment, 18 patients (90%) showed considerable reduction in SUV(max) value (>50%) suggestive of response to treatment; only 2 patients did not show meaningful reduction in metabolic activity. Our preliminary study demonstrates that quantitative analysis provided by PET correlates with response to cryoablation therapy as assessed by CT data and clinical VAS evaluation.
Error modelling of quantum Hall array resistance standards
NASA Astrophysics Data System (ADS)
Marzano, Martina; Oe, Takehiko; Ortolano, Massimo; Callegaro, Luca; Kaneko, Nobu-Hisa
2018-04-01
Quantum Hall array resistance standards (QHARSs) are integrated circuits composed of interconnected quantum Hall effect elements that allow the realization of virtually arbitrary resistance values. In recent years, techniques were presented to efficiently design QHARS networks. An open problem is that of the evaluation of the accuracy of a QHARS, which is affected by contact and wire resistances. In this work, we present a general and systematic procedure for the error modelling of QHARSs, which is based on modern circuit analysis techniques and Monte Carlo evaluation of the uncertainty. As a practical example, this method of analysis is applied to the characterization of a 1 MΩ QHARS developed by the National Metrology Institute of Japan. Software tools are provided to apply the procedure to other arrays.
An Example of Process Evaluation.
ERIC Educational Resources Information Center
Karl, Marion C.
The inappropriateness of standard experimental research design, which can stifle innovations, is discussed in connection with the problems of designing practical techniques for evaluating a Title III curriculum development project. The project, involving 12 school districts and 2,500 students, teaches concept understanding, critical thinking, and…
de Freitas, Paulo B; Jaric, Slobodan
2009-04-01
We evaluated coordination of the hand grip force (GF; normal component of the force acting at the hand-object contact area) and load force (LF; the tangential component) in a variety of grasping techniques and two LF directions. Thirteen participants exerted a continuous sinusoidal LF pattern against externally fixed handles applying both standard (i.e., using either the tips of the digits or the palms; the precision and palm grasps, respectively) and non-standard grasping techniques (using wrists and the dorsal finger areas; the wrist and fist grasp). We hypothesized (1) that the non-standard grasping techniques would provide deteriorated indices of force coordination when compared with the standard ones, and (2) that the nervous system would be able to adjust GF to the differences in friction coefficients of various skin areas used for grasping. However, most of the indices of force coordination remained similar across the tested grasping techniques, while the GF adjustments for the differences in friction coefficients (highest in the palm and the lowest in the fist and wrist grasp) provided inconclusive results. As hypothesized, GF relative to the skin friction was lowest in the precision grasp, but highest in the palm grasp. Therefore, we conclude that (1) the elaborate coordination of GF and LF consistently seen across the standard grasping techniques could be generalized to the non-standard ones, while (2) the ability to adjust GF using the same grasping technique to the differences in friction of various objects cannot be fully generalized to the GF adjustment when different grasps (i.e., hand segments) are used to manipulate the same object. Due to the importance of the studied phenomena for understanding both the functional and neural control aspects of manipulation, future studies should extend the current research to the transient and dynamic tasks, as well as to the general role of friction in our mechanical interactions with the environment.
Dabarakis, Nikolaos N; Alexander, Veis; Tsirlis, Anastasios T; Parissis, Nikolaos A; Nikolaos, Maroufidis
2007-01-01
To clinically evaluate the jet injection Injex (Rösch AG Medizintechnik) using 2 different anesthetic solutions, and to compare the jet injection and the standard needle injection techniques. Of the 32 patients in the study, 10 received mepivacaine 3% anesthetic solution by means of the jet injection technique, while the remaining 22 patients received lidocaine 2% with epinephrine 1:80,000 by the same method. The 14 patients in whom pulp anesthesia was achieved were selected for an additional evaluation of the pulp reaction using standard needle injection anesthesia. The differences between the 2 compounds with Injex were statistically evaluated by means of independent-samples t test analysis. The differences between subgroups receiving both jet injection and needle injection anesthesia were evaluated by means of paired t test analysis. The administration of mepivacaine 3% using Injex did not achieve pulp anesthesia in any of the 10 patients, although the soft tissue anesthesia was successful. The administration of lidocaine with epinephrine using Injex resulted in pulp anesthesia in only 14 patients; soft tissue anesthesia was observed in all patients of this group. There was no statistically significant difference between Injex and the needle injection technique in onset of anesthesia. However, the duration of anesthesia was significantly longer for the needle infiltration group than for the Injex injection group. The anesthetic solution should be combined with a vasoconstriction agent when the Injex technique is implemented.
Grounds, Miranda D.; Radley, Hannah G.; Lynch, Gordon S.; Nagaraju, Kanneboyina; De Luca, Annamaria
2008-01-01
This review discusses various issues to consider when developing standard operating procedures for pre-clinical studies in the mdx mouse model of Duchenne muscular dystrophy (DMD). The review describes and evaluates a wide range of techniques used to measure parameters of muscle pathology in mdx mice and identifies some basic techniques that might comprise standardised approaches for evaluation. While the central aim is to provide a basis for the development of standardised procedures to evaluate efficacy of a drug or a therapeutic strategy, a further aim is to gain insight into pathophysiological mechanisms in order to identify other therapeutic targets. The desired outcome is to enable easier and more rigorous comparison of pre-clinical data from different laboratories around the world, in order to accelerate identification of the best pre-clinical therapies in the mdx mouse that will fast-track translation into effective clinical treatments for DMD. PMID:18499465
Standardized plant disease evaluations will enhance resistance gene discovery
USDA-ARS?s Scientific Manuscript database
Gene discovery and marker development using DNA-based tools require plant populations with well documented phenotypes. If dissimilar phenotype evaluation methods or data scoring techniques are employed with different crops, or at different labs for the same crops, then data mining for genetic marker...
MICROWAVE-ASSISTED EXTRACTION OF ORGANIC COMPOUNDS FROM STANDARD REFERENCE SOILS AND SEDIMENTS
As part of an ongoing evaluation of new sample preparation techniques by the U.S. Environmental Protection Agency (EPA), especially those that minimize waste solvents, microwave-assisted extraction (MAE) of organic compounds from solid materials (or "matrices") was evaluated. Six...
Sil'veĭstrova, O Iu; Domonova, É A; Shipulina, O Iu
2014-04-01
The validation of kit of reagents destined to detection and quantitative evaluation of DNA of human cytomegalovirus in biological material using polymerase chain reaction technique in real time operation mode was implemented. The comparison was made against international WHO standard--The first WHO international standard for human cytomegalovirus to implement measures the kit of reagents "AmpliSens CMV-screen/monitor-FL" and standard sample of enterprise DNA HCMV (The central research institute of epidemiology of Rospotrebnadzor) was applied. The fivefold dilution of international WHO standard and standard sample of enterprise were carried out in concentrations of DNA HCMV from 106 to 102. The arrangement of polymerase chain reaction and analysis of results were implemented using programed amplifier with system of detection of fluorescent signal in real-time mode "Rotor-Gene Q" ("Qiagen", Germany). In the total of three series of experiments, all stages of polymerase chain reaction study included, the coefficient of translation of quantitative evaluation of DNA HCMV from copy/ml to ME/ml equal to 0.6 was introduced for this kit of reagents.
NASA Astrophysics Data System (ADS)
Oudry, Jennifer; Lynch, Ted; Vappou, Jonathan; Sandrin, Laurent; Miette, Véronique
2014-10-01
Elastographic techniques used in addition to imaging techniques (ultrasound, resonance magnetic or optical) provide new clinical information on the pathological state of soft tissues. However, system-dependent variation in elastographic measurements may limit the clinical utility of these measurements by introducing uncertainty into the measurement. This work is aimed at showing differences in the evaluation of the elastic properties of phantoms performed by four different techniques: quasi-static compression, dynamic mechanical analysis, vibration-controlled transient elastography and hyper-frequency viscoelastic spectroscopy. Four Zerdine® gel materials were tested and formulated to yield a Young’s modulus over the range of normal and cirrhotic liver stiffnesses. The Young’s modulus and the shear wave speed obtained with each technique were compared. Results suggest a bias in elastic property measurement which varies with systems and highlight the difficulty in finding a reference method to determine and assess the elastic properties of tissue-mimicking materials. Additional studies are needed to determine the source of this variation, and control for them so that accurate, reproducible reference standards can be made for the absolute measurement of soft tissue elasticity.
Oudry, Jennifer; Lynch, Ted; Vappou, Jonathan; Sandrin, Laurent; Miette, Véronique
2014-10-07
Elastographic techniques used in addition to imaging techniques (ultrasound, resonance magnetic or optical) provide new clinical information on the pathological state of soft tissues. However, system-dependent variation in elastographic measurements may limit the clinical utility of these measurements by introducing uncertainty into the measurement. This work is aimed at showing differences in the evaluation of the elastic properties of phantoms performed by four different techniques: quasi-static compression, dynamic mechanical analysis, vibration-controlled transient elastography and hyper-frequency viscoelastic spectroscopy. Four Zerdine® gel materials were tested and formulated to yield a Young's modulus over the range of normal and cirrhotic liver stiffnesses. The Young's modulus and the shear wave speed obtained with each technique were compared. Results suggest a bias in elastic property measurement which varies with systems and highlight the difficulty in finding a reference method to determine and assess the elastic properties of tissue-mimicking materials. Additional studies are needed to determine the source of this variation, and control for them so that accurate, reproducible reference standards can be made for the absolute measurement of soft tissue elasticity.
[Standardization of Blastocystis hominis diagnosis using different staining techniques].
Eymael, Dayane; Schuh, Graziela Maria; Tavares, Rejane Giacomelli
2010-01-01
The present study was carried out from March to May 2008, with the aim of evaluating the effectiveness of different techniques for diagnosing Blastocystis hominis in a sample of the population attended at the Biomedicine Laboratory of Feevale University, Novo Hamburgo, Rio Grande do Sul. On hundred feces samples from children and adults were evaluated. After collection, the samples were subjected to the techniques of spontaneous sedimentation (HPJ), sedimentation in formalin-ether (Ritchie) and staining by means of Gram and May-Grünwald-Giemsa (MGG). The presence of Blastocystis hominis was observed in 40 samples, when staining techniques were used (MGG and Gram), while sedimentation techniques were less efficient (32 positive samples using the Ritchie technique and 20 positive samples using the HPJ technique). Our results demonstrate that HPJ was less efficient than the other methods, thus indicating the need to include laboratory techniques that enable parasite identification on a routine basis.
Cross-platform comparison of nucleic acid hybridization: toward quantitative reference standardsa
Halvorsen, Ken; Agris, Paul F.
2014-01-01
Measuring interactions between biological molecules is vitally important to both basic and applied research, as well as development of pharmaceuticals. While a wide and growing range of techniques are available to measure various kinetic and thermodynamic properties of interacting biomolecules, it can be difficult to compare data across techniques of different laboratories and personnel, or even across different instruments using the same technique. Here we evaluate relevant biological interactions based on complementary DNA and RNA oligonucleotides that could be used as reference standards for many experimental systems. We measured thermodynamics of duplex formation using Isothermal Titration Calorimetry, Differential Scanning Calorimetry, and UV-Vis monitored denaturation/renaturation. These standards can be used to validate results, compare data from disparate techniques, act as a teaching tool for laboratory classes, or potentially to calibrate instruments. The RNA and DNA standards have many attractive features including low cost, high purity, easily measureable concentrations, and minimal handling concerns, making them ideal for use as a reference material. PMID:25124363
Use of Standardized, Quantitative Digital Photography in a Multicenter Web-based Study
Molnar, Joseph A.; Lew, Wesley K.; Rapp, Derek A.; Gordon, E. Stanley; Voignier, Denise; Rushing, Scott; Willner, William
2009-01-01
Objective: We developed a Web-based, blinded, prospective, randomized, multicenter trial, using standardized digital photography to clinically evaluate hand burn depth and accurately determine wound area with digital planimetry. Methods: Photos in each center were taken with identical digital cameras with standardized settings on a custom backdrop developed at Wake Forest University containing a gray, white, black, and centimeter scale. The images were downloaded, transferred via the Web, and stored on servers at the principal investigator's home institution. Color adjustments to each photo were made using Adobe Photoshop 6.0 (Adobe, San Jose, Calif). In an initial pilot study, model hands marked with circles of known areas were used to determine the accuracy of the planimetry technique. Two-dimensional digital planimetry using SigmaScan Pro 5.0 (SPSS Science, Chicago, Ill) was used to calculate wound area from the digital images. Results: Digital photography is a simple and cost-effective method for quantifying wound size when used in conjunction with digital planimetry (SigmaScan) and photo enhancement (Adobe Photoshop) programs. The accuracy of the SigmaScan program in calculating predetermined areas was within 4.7% (95% CI, 3.4%–5.9%). Dorsal hand burns of the initial 20 patients in a national study involving several centers were evaluated with this technique. Images obtained by individuals denying experience in photography proved reliable and useful for clinical evaluation and quantification of wound area. Conclusion: Standardized digital photography may be used quantitatively in a Web-based, multicenter trial of burn care. This technique could be modified for other medical studies with visual endpoints. PMID:19212431
Use of standardized, quantitative digital photography in a multicenter Web-based study.
Molnar, Joseph A; Lew, Wesley K; Rapp, Derek A; Gordon, E Stanley; Voignier, Denise; Rushing, Scott; Willner, William
2009-01-01
We developed a Web-based, blinded, prospective, randomized, multicenter trial, using standardized digital photography to clinically evaluate hand burn depth and accurately determine wound area with digital planimetry. Photos in each center were taken with identical digital cameras with standardized settings on a custom backdrop developed at Wake Forest University containing a gray, white, black, and centimeter scale. The images were downloaded, transferred via the Web, and stored on servers at the principal investigator's home institution. Color adjustments to each photo were made using Adobe Photoshop 6.0 (Adobe, San Jose, Calif). In an initial pilot study, model hands marked with circles of known areas were used to determine the accuracy of the planimetry technique. Two-dimensional digital planimetry using SigmaScan Pro 5.0 (SPSS Science, Chicago, Ill) was used to calculate wound area from the digital images. Digital photography is a simple and cost-effective method for quantifying wound size when used in conjunction with digital planimetry (SigmaScan) and photo enhancement (Adobe Photoshop) programs. The accuracy of the SigmaScan program in calculating predetermined areas was within 4.7% (95% CI, 3.4%-5.9%). Dorsal hand burns of the initial 20 patients in a national study involving several centers were evaluated with this technique. Images obtained by individuals denying experience in photography proved reliable and useful for clinical evaluation and quantification of wound area. Standardized digital photography may be used quantitatively in a Web-based, multicenter trial of burn care. This technique could be modified for other medical studies with visual endpoints.
Multiple Myeloma Minimal Residual Disease.
Paiva, Bruno; García-Sanz, Ramón; San Miguel, Jesús F
Assessment of minimal residual disease (MRD) is becoming standard diagnostic care for potentially curable neoplasms such as some acute leukemias as well as chronic myeloid and lymphocytic leukemia. Although multiple myeloma (MM) remains as an incurable disease, around half of the patients achieve complete remission (CR), and recent data suggests increasing rates of curability with "total-therapy-like" programs. This landscape is likely to be improved with the advent of new antibodies and small molecules. Therefore, conventional serological and morphological techniques have become suboptimal for sensitive evaluation of highly effective treatment strategies. Although, existing data suggests that MRD could be used as a biomarker to evaluate treatment efficacy, help on therapeutic decisions, and act as surrogate for overall survival, the role of MRD in MM is still a matter of extensive debate. Here, we review the different levels of remission used to define depth of response in MM and their clinical significance, as well as the prognostic value and unique characteristics of MRD detection using immunophenotypic, molecular, and imaging techniques. Key facts The higher efficacy of new treatment strategies for MM demand the incorporation of highly sensitive techniques to monitor treatment efficacy MRD could be used as a more potent surrogate biomarker for survival than standard CR We need to understand the pros and cons of the different MRD techniques The time has come to incorporate highly sensitive, cost-effective, readily available, and standardized MRD techniques into clinical trials to assess its role in therapeutic decisions.
Electrical bioimpedance and other techniques for gastric emptying and motility evaluation
Huerta-Franco, María Raquel; Vargas-Luna, Miguel; Montes-Frausto, Juana Berenice; Flores-Hernández, Corina; Morales-Mata, Ismael
2012-01-01
The aim of this article is to identify non-invasive, inexpensive, highly sensitive and accurate techniques for evaluating and diagnosing gastric diseases. In the case of the stomach, there are highly sensitive and specific methods for assessing gastric motility and emptying (GME). However, these methods are invasive, expensive and/or not technically feasible for all clinicians and patients. We present a summary of the most relevant international information on non-invasive methods and techniques for clinically evaluating GME. We particularly emphasize the potential of gastric electrical bioimpedance (EBI). EBI was initially used mainly in gastric emptying studies and was essentially abandoned in favor of techniques such as electrogastrography and the gold standard, scintigraphy. The current research evaluating the utility of gastric EBI either combines this technique with other frequently used techniques or uses new methods for gastric EBI signal analysis. In this context, we discuss our results and those of other researchers who have worked with gastric EBI. In this review article, we present the following topics: (1) a description of the oldest methods and procedures for evaluating GME; (2) an explanation of the methods currently used to evaluate gastric activity; and (3) a perspective on the newest trends and techniques in clinical and research GME methods. We conclude that gastric EBI is a highly effective non-invasive, easy to use and inexpensive technique for assessing GME. PMID:22368782
The Impact of Spatial Correlation and Incommensurability on Model Evaluation
Standard evaluations of air quality models rely heavily on a direct comparison of monitoring data matched with the model output for the grid cell containing the monitor’s location. While such techniques may be adequate for some applications, conclusions are limited by such facto...
Multi-Quadrant Biopsy Technique Improves Diagnostic Ability in Large Heterogeneous Renal Masses.
Abel, E Jason; Heckman, Jennifer E; Hinshaw, Louis; Best, Sara; Lubner, Meghan; Jarrard, David F; Downs, Tracy M; Nakada, Stephen Y; Lee, Fred T; Huang, Wei; Ziemlewicz, Timothy
2015-10-01
Percutaneous biopsy obtained from a single location is prone to sampling error in large heterogeneous renal masses, leading to nondiagnostic results or failure to detect poor prognostic features. We evaluated the accuracy of percutaneous biopsy for large renal masses using a modified multi-quadrant technique vs a standard biopsy technique. Clinical and pathological data for all patients with cT2 or greater renal masses who underwent percutaneous biopsy from 2009 to 2014 were reviewed. The multi-quadrant technique was defined as multiple core biopsies from at least 4 separate solid enhancing areas in the tumor. The incidence of nondiagnostic findings, sarcomatoid features and procedural complications was recorded, and concordance between biopsy specimens and nephrectomy pathology was compared. A total of 122 biopsies were performed for 117 tumors in 116 patients (46 using the standard biopsy technique and 76 using the multi-quadrant technique). Median tumor size was 10 cm (IQR 8-12). Biopsy was nondiagnostic in 5 of 46 (10.9%) standard and 0 of 76 (0%) multi-quadrant biopsies (p=0.007). Renal cell carcinoma was identified in 96 of 115 (82.0%) tumors and nonrenal cell carcinoma tumors were identified in 21 (18.0%). One complication occurred using the standard biopsy technique and no complications were reported using the multi-quadrant technique. Sarcomatoid features were present in 23 of 96 (23.9%) large renal cell carcinomas studied. Sensitivity for identifying sarcomatoid features was higher using the multi-quadrant technique compared to the standard biopsy technique at 13 of 15 (86.7%) vs 2 of 8 (25.0%) (p=0.0062). The multi-quadrant percutaneous biopsy technique increases the ability to identify aggressive pathological features in large renal tumors and decreases nondiagnostic biopsy rates. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Recent Advances in Cardiovascular Magnetic Resonance Techniques and Applications
Salerno, Michael; Sharif, Behzad; Arheden, Håkan; Kumar, Andreas; Axel, Leon; Li, Debiao; Neubauer, Stefan
2018-01-01
Cardiovascular magnetic resonance imaging has become the gold standard for evaluating myocardial function, volumes, and scarring. Additionally, cardiovascular magnetic resonance imaging is unique in its comprehensive tissue characterization, including assessment of myocardial edema, myocardial siderosis, myocardial perfusion, and diffuse myocardial fibrosis. Cardiovascular magnetic resonance imaging has become an indispensable tool in the evaluation of congenital heart disease, heart failure, cardiac masses, pericardial disease, and coronary artery disease. This review will highlight some recent novel cardiovascular magnetic resonance imaging techniques, concepts, and applications. PMID:28611116
Chemical vapor deposition growth
NASA Technical Reports Server (NTRS)
Ruth, R. P.; Manasevit, H. M.; Kenty, J. L.; Moudy, L. A.; Simpson, W. I.; Yang, J. J.
1976-01-01
The chemical vapor deposition (CVD) method for the growth of Si sheet on inexpensive substrate materials is investigated. The objective is to develop CVD techniques for producing large areas of Si sheet on inexpensive substrate materials, with sheet properties suitable for fabricating solar cells meeting the technical goals of the Low Cost Silicon Solar Array Project. Specific areas covered include: (1) modification and test of existing CVD reactor system; (2) identification and/or development of suitable inexpensive substrate materials; (3) experimental investigation of CVD process parameters using various candidate substrate materials; (4) preparation of Si sheet samples for various special studies, including solar cell fabrication; (5) evaluation of the properties of the Si sheet material produced by the CVD process; and (6) fabrication and evaluation of experimental solar cell structures, using standard and near-standard processing techniques.
Improved ultrasonic standard reference blocks
NASA Technical Reports Server (NTRS)
Eitzen, D. G.; Sushinsky, G. F.; Chwirut, D. J.; Bechtoldt, C. J.; Ruff, A. W.
1976-01-01
A program to improve the quality, reproducibility and reliability of nondestructive testing through the development of improved ASTM-type ultrasonic reference standards is described. Reference blocks of aluminum, steel, and titanium alloys are to be considered. Equipment representing the state-of-the-art in laboratory and field ultrasonic equipment was obtained and evaluated. RF and spectral data on ten sets of ultrasonic reference blocks have been taken as part of a task to quantify the variability in response from nominally identical blocks. Techniques for residual stress, preferred orientation, and micro-structural measurements were refined and are applied to a reference block rejected by the manufacturer during fabrication in order to evaluate the effect of metallurgical condition on block response. New fabrication techniques for reference blocks are discussed and ASTM activities are summarized.
NASA Technical Reports Server (NTRS)
Mccandles, L. C.; Davies, L. G.
1973-01-01
Techniques were studied to reinforce or strengthen electroformed nickel to allow a fuller utilization of electroforming as a reliable and low cost fabrication technique for regenerately cooled thrust chambers. Techniques for wire wrapping while electrodepositing were developed that can result in a structurally strong wall with less weight than a conventional electroformed wall. Also a technique of codepositing submicron sized THO2 particles with the nickel to form a dispersion strengthened structure was evaluated. The standard nickel cylinders exhibited an average hoop strength of 80,000 psi with a yield strength of 65,000 psi and a modulus of 25.6 x 10 to the 6th power psi. The as produced dispersion strengthened nickel showed a hoop strength of 97,000 psi with a yield strength of 67,000 psi. This is an increase of 17,000 psi or 21% over the standard nickel hoop strength. The wire wrapping cylinders showed an increased strength over the standard nickel test samples of 26,000 to 66,800 psi which is in the range of 26 to 104% increase in strength over the base standard nickel. These latter test results are indicative of a volume percent wire reinforcement from 15 to 31. The measured hoop strengths agree with calculated composite strengths based upon rule of mixtures.
NASA Astrophysics Data System (ADS)
Łazarek, Łukasz; Antończak, Arkadiusz J.; Wójcik, Michał R.; Drzymała, Jan; Abramski, Krzysztof M.
2014-07-01
Laser-induced breakdown spectroscopy (LIBS), like many other spectroscopic techniques, is a comparative method. Typically, in qualitative analysis, synthetic certified standard with a well-known elemental composition is used to calibrate the system. Nevertheless, in all laser-induced techniques, such calibration can affect the accuracy through differences in the overall composition of the chosen standard. There are also some intermediate factors, which can cause imprecision in measurements, such as optical absorption, surface structure and thermal conductivity. In this work the calibration performed for the LIBS technique utilizes pellets made directly from the tested materials (old well-characterized samples). This choice produces a considerable improvement in the accuracy of the method. This technique was adopted for the determination of trace elements in industrial copper concentrates, standardized by conventional atomic absorption spectroscopy with a flame atomizer. A series of copper flotation concentrate samples was analyzed for three elements: silver, cobalt and vanadium. We also proposed a method of post-processing the measurement data to minimize matrix effects and permit reliable analysis. It has been shown that the described technique can be used in qualitative and quantitative analyses of complex inorganic materials, such as copper flotation concentrates. It was noted that the final validation of such methodology is limited mainly by the accuracy of the characterization of the standards.
Jha, Abhinav K.; Kupinski, Matthew A.; Rodríguez, Jeffrey J.; Stephen, Renu M.; Stopeck, Alison T.
2012-01-01
In many studies, the estimation of the apparent diffusion coefficient (ADC) of lesions in visceral organs in diffusion-weighted (DW) magnetic resonance images requires an accurate lesion-segmentation algorithm. To evaluate these lesion-segmentation algorithms, region-overlap measures are used currently. However, the end task from the DW images is accurate ADC estimation, and the region-overlap measures do not evaluate the segmentation algorithms on this task. Moreover, these measures rely on the existence of gold-standard segmentation of the lesion, which is typically unavailable. In this paper, we study the problem of task-based evaluation of segmentation algorithms in DW imaging in the absence of a gold standard. We first show that using manual segmentations instead of gold-standard segmentations for this task-based evaluation is unreliable. We then propose a method to compare the segmentation algorithms that does not require gold-standard or manual segmentation results. The no-gold-standard method estimates the bias and the variance of the error between the true ADC values and the ADC values estimated using the automated segmentation algorithm. The method can be used to rank the segmentation algorithms on the basis of both accuracy and precision. We also propose consistency checks for this evaluation technique. PMID:22713231
Yimer, Mulat; Hailu, Tadesse; Mulu, Wondemagegn; Abera, Bayeh
2015-12-26
Although the sensitivity of Wet mount technique is questionable, it is the major diagnostic technique for routine diagnosis of intestinal parasitosis in Ethiopia. Therefore, the aim of this study was the evaluation performance of diagnostic methods of intestinal parasitosis in school age children in Ethiopia. A cross sectional study was conducted from May to June 2013. Single stool sample was processed for direct, Formol ether concentration (FEC) and Kato Katz methods. The sensitivity and negative predictive value (NPV) of diagnostic tests were calculated in terms of the "Gold" standard method (the combined result of the three methods altogether). A total of 422 school age children were participated in this study. The prevalence of intestinal parasites was high (74.6%) with Kato Katz technique. The sensitivity of Wet mount, FEC and Kato Katz tests against the Gold standard test was 48.9, 63.1 and 93.7%, respectively. Kato Katz technique revealed a better NPV 80.4 (80.1-80.6) as compared to the Wet mount (33.7%) and FEC techniques (41.3%). In this study, the Kato Katz technique outperformed the other two methods but the true values for sensitivity, specificity and diagnostic values are not known. Moreover, it is labor intensive and not easily accessible. Hence, it is preferable to use FEC technique to complement the Wet mount test.
Direct magnitude estimates of speech intelligibility in dysarthria: effects of a chosen standard.
Weismer, Gary; Laures, Jacqueline S
2002-06-01
Direct magnitude estimation (DME) has been used frequently as a perceptual scaling technique in studies of the speech intelligibility of persons with speech disorders. The technique is typically used with a standard, or reference stimulus, chosen as a good exemplar of "midrange" intelligibility. In several published studies, the standard has been chosen subjectively, usually on the basis of the expertise of the investigators. The current experiment demonstrates that a fixed set of sentence-level utterances, obtained from 4 individuals with dysarthria (2 with Parkinson disease, 2 with traumatic brain injury) as well as 3 neurologically normal speakers, is scaled differently depending on the identity of the standard. Four different standards were used in the main experiment, three of which were judged qualitatively in two independent evaluations to be good exemplars of midrange intelligibility. Acoustic analyses did not reveal obvious differences between these four standards but suggested that the standard with the worst-scaled intelligibility had much poorer voice source characteristics compared to the other three standards. Results are discussed in terms of possible standardization of midrange intelligibility exemplars for DME experiments.
Visually guided tube thoracostomy insertion comparison to standard of care in a large animal model.
Hernandez, Matthew C; Vogelsang, David; Anderson, Jeff R; Thiels, Cornelius A; Beilman, Gregory; Zielinski, Martin D; Aho, Johnathon M
2017-04-01
Tube thoracostomy (TT) is a lifesaving procedure for a variety of thoracic pathologies. The most commonly utilized method for placement involves open dissection and blind insertion. Image guided placement is commonly utilized but is limited by an inability to see distal placement location. Unfortunately, TT is not without complications. We aim to demonstrate the feasibility of a disposable device to allow for visually directed TT placement compared to the standard of care in a large animal model. Three swine were sequentially orotracheally intubated and anesthetized. TT was conducted utilizing a novel visualization device, tube thoracostomy visual trocar (TTVT) and standard of care (open technique). Position of the TT in the chest cavity were recorded using direct thoracoscopic inspection and radiographic imaging with the operator blinded to results. Complications were evaluated using a validated complication grading system. Standard descriptive statistical analyses were performed. Thirty TT were placed, 15 using TTVT technique, 15 using standard of care open technique. All of the TT placed using TTVT were without complication and in optimal position. Conversely, 27% of TT placed using standard of care open technique resulted in complications. Necropsy revealed no injury to intrathoracic organs. Visual directed TT placement using TTVT is feasible and non-inferior to the standard of care in a large animal model. This improvement in instrumentation has the potential to greatly improve the safety of TT. Further study in humans is required. Therapeutic Level II. Copyright © 2017 Elsevier Ltd. All rights reserved.
Devesa, V; Rovesti, G L; Urrutia, P G; Sanroman, F; Rodriguez-Quiros, J
2015-06-01
The objective of this study was to evaluate technical feasibility and efficacy of a joint distraction technique by traction stirrup to facilitate shoulder arthroscopy and assess potential soft tissue damage. Twenty shoulders were evaluated radiographically before distraction. Distraction was applied with loads from 40 N up to 200 N, in 40 N increments, and the joint space was recorded at each step by radiographic images. The effects of joint flexion and intra-articular air injection at maximum load were evaluated. Radiographic evaluation was performed after distraction to evaluate ensuing joint laxity. Joint distraction by traction stirrup technique produces a significant increase in the joint space; an increase in joint laxity could not be inferred by standard and stress radiographs. However, further clinical studies are required to evaluate potential neurovascular complications. A wider joint space may be useful to facilitate arthroscopy, reducing the likelihood for iatrogenic damage to intra-articular structures. Copyright © 2015 Elsevier Ltd. All rights reserved.
A new serotyping method for Klebsiella species: evaluation of the technique.
Riser, E; Noone, P; Bonnet, M L
1976-01-01
A new indirect fluorescent typing method for Klebsiella species is compared with an established method, capsular swelling. The fluorescent antibody (FA) technique was tested with standards and unknowns, and the results were checked by capsular swelling. Several unknowns were sent away for confirmation of typing, by capsular swelling. The FA method was also tried by a technician in the routine department for blind identification of standards. Fluorescence typing gives close correlation with the established capsular swelling technique but has greater sensitivity; allows more econimical use of expensive antisera; possesses greater objectivity as it requires less operator skill in the reading of results; resolves most of the cross reactions observed with capsular swelling; and has a higher per cent success rate in identification. PMID:777043
Herreros, María Luisa; Tagarro, Alfredo; García-Pose, Araceli; Sánchez, Aida; Cañete, Alfonso; Gili, Pablo
2015-01-01
OBJECTIVE: To evaluate the accuracy of diagnosing urinary tract infections using a new, recently described, standardized clean-catch collection technique. METHODS: Cross-sectional study of infants <90 days old admitted due to fever without a source, with two matched samples of urine obtained using two different methods: clean-catch standardized stimulation technique and bladder catheterization. RESULTS: Sixty paired urine cultures were obtained. The median age was 44-days-old. Seventeen percent were male infants. Clean-catch technique sensitivity was 97% (95% CI 82% to 100%) and specificity was 89% (95% CI 65% to 98%). The contamination rate of clean-catch samples was lower (5%) than the contamination rate of catheter specimens (8%). CONCLUSIONS: The sensitivity and specificity of urine cultures obtained using the clean-catch method through the new technique were accurate and the contamination rate was low. These results suggest that this technique is a valuable, alternative method for urinary tract infection diagnosis. PMID:26435675
Numerical evaluation of the radiation from unbaffled, finite plates using the FFT
NASA Technical Reports Server (NTRS)
Williams, E. G.
1983-01-01
An iteration technique is described which numerically evaluates the acoustic pressure and velocity on and near unbaffled, finite, thin plates vibrating in air. The technique is based on Rayleigh's integral formula and its inverse. These formulas are written in their angular spectrum form so that the fast Fourier transform (FFT) algorithm may be used to evaluate them. As an example of the technique the pressure on the surface of a vibrating, unbaffled disk is computed and shown to be in excellent agreement with the exact solution using oblate spheroidal functions. Furthermore, the computed velocity field outside the disk shows the well-known singularity at the rim of the disk. The radiated fields from unbaffled flat sources of any geometry with prescribed surface velocity may be evaluated using this technique. The use of the FFT to perform the integrations in Rayleigh's formulas provides a great savings in computation time compared with standard integration algorithms, especially when an array processor can be used to implement the FFT.
Shrader, Sarah; Dunn, Brianne; Blake, Elizabeth; Phillips, Cynthia
2015-05-25
To determine the impact of incorporating standardized colleague simulations on pharmacy students' confidence and interprofessional communication skills. Four simulations using standardized colleagues portraying attending physicians in inpatient and outpatient settings were integrated into a required course. Pharmacy students interacted with the standardized colleagues using the Situation, Background, Assessment, Request/Recommendation (SBAR) communication technique and were evaluated on providing recommendations while on simulated inpatient rounds and in an outpatient clinic. Additionally, changes in student attitudes and confidence toward interprofessional communication were assessed with a survey before and after the standardized colleague simulations. One hundred seventy-one pharmacy students participated in the simulations. Student interprofessional communication skills improved after each simulation. Student confidence with interprofessional communication in both inpatient and outpatient settings significantly improved. Incorporation of simulations using standardized colleagues improves interprofessional communication skills and self-confidence of pharmacy students.
Emmanuel, Samson; Shantaram, Kulkarni; Sushil, Kumar C; Manoj, Likhitkar
2013-04-01
Success of non-surgical root canal treatment is predicted by meticulous cleaning and shaping of the root canal system, three-dimensional obturation and a well-fitting "leakage-free" coronal restoration. The techniques of obturation that are available have their own relative position in the historical development of filling techniques. Over the years, pitfalls with one technique have often led to the development of newer methods of obturation, along with the recognition that no one method of obturation may satisfy all clinical cases. A total of 120 extracted human permanent anterior maxillary and mandibular single rooted teeth were selected for the present study and divided into 3 groups based on the method of obturation technique. Following the preparation the patency at the apical foramen was confirmed by passing a file #15. After obturation of all three groups, teeth were immersed in 1% of aqueous methylene blue dye for a period of two weeks and then samples were subjected to spectrophotometric analysis. The present study was conducted to evaluate in vitro the spectrophotometric analysis to quantitatively analyze relative amount of dye penetration using lateral condensation (Group I), Obtura II (Group II ), Thermafil obturating technique (Group III) with ZOE sealer used in all groups. Teeth obturated with lateral condensation (Group I) shows mean value of 0.0243 and standard deviation of 0.0056. The Group II thermoplasticized injectable moulded Guttapercha (Obtura II) showed 0.0239 mean and standard deviation value of 0.0045 and Group III Thermafil obturation technique shows 0.0189 as mean value and 0.0035 standard deviation values. Following conclusion was drawn from the present study. Group III i.e., Thermafil obturating technique shows minimum mean apical dye penetration compared to Group II (ObturaII) and Group I (lateral condensation).Lateral condensation shows maximum mean apical dye penetration in all three groups.There is no significant difference between the apical dye penetration of lateral condensation and Obtura II. Obturation, lateral condensation, Obtura II, Thermafil, Spectrophotometer, dye penetration. How to cite this article: Samson E, Kulkarni S, Sushil K C, Likhitkar M. An In-Vitro Evaluation and Comparison of Apical Sealing Ability of Three Different Obturation Technique - Lateral Condensation, Obtura II, and Thermafil. J Int Oral Health 2013; 5(2):35-43.
Art Therapy: What Is Art Therapy?
... American Art Therapy Association’s website. Educational requirements include theories of art therapy, counseling, and psychotherapy; ethics and standards of practice; assessment and evaluation; individual, group, and family art therapy techniques; human and creative ...
Design New Buildings To Save Energy -- and Money
ERIC Educational Resources Information Center
Rittelmann, Richard
1974-01-01
Buildings should be designed so that energy systems function with maximum efficiency. Re-evaluation of standards for ventilation and lighting is recommended. Heat recovery techniques and topography can reduce heating loads. (MF)
NASA Technical Reports Server (NTRS)
Navard, Sharon E.
1989-01-01
In recent years there has been a push within NASA to use statistical techniques to improve the quality of production. Two areas where statistics are used are in establishing product and process quality control of flight hardware and in evaluating the uncertainty of calibration of instruments. The Flight Systems Quality Engineering branch is responsible for developing and assuring the quality of all flight hardware; the statistical process control methods employed are reviewed and evaluated. The Measurement Standards and Calibration Laboratory performs the calibration of all instruments used on-site at JSC as well as those used by all off-site contractors. These calibrations must be performed in such a way as to be traceable to national standards maintained by the National Institute of Standards and Technology, and they must meet a four-to-one ratio of the instrument specifications to calibrating standard uncertainty. In some instances this ratio is not met, and in these cases it is desirable to compute the exact uncertainty of the calibration and determine ways of reducing it. A particular example where this problem is encountered is with a machine which does automatic calibrations of force. The process of force calibration using the United Force Machine is described in detail. The sources of error are identified and quantified when possible. Suggestions for improvement are made.
Acousto-ultrasonic nondestructive evaluation of materials using laser beam generation and detection
NASA Technical Reports Server (NTRS)
Huber, Robert D.; Green, Robert E., Jr.; Vary, Alex; Kautz, Harold
1990-01-01
Presented in viewgraph format, the possibility of using laser generation and detection of ultrasound to replace piezoelectric transducers for the acousto-ultrasonic technique is advanced. The advantages and disadvantages of laser acousto-ultrasonics are outlined. Laser acousto-ultrasonics complements standard piezoelectric acousto-ultrasonics and offers non-contact nondestructive evaluation.
Illuminative Evaluation: Meeting the Special Needs of Feminist Projects.
ERIC Educational Resources Information Center
Shapiro, Joan P.; Reed, Beth
"Illuminative evaluation," as defined by Parlett and Hamilton, "is not a standard methodological package but a general strategy. It aims to be both adaptable and eclectic. The choice of research tactics follows not from research doctrine, but from decisions in each case as to the best available techniques; the problem defines the…
Suggested Format and Content of a Work Sample Manual: [With Examples].
ERIC Educational Resources Information Center
Wisconsin Univ. - Stout, Menomonie. Dept. of Rehabilitation and Manpower Services. Materials Development Center.
Work samples are job tasks used as a diagnostic tool in the evaluation of vocational rehabilitation clients. The manual was developed to provide a standardized format for the construction, administration, and interpretation of necessary information from work sample assessment techniques used by vocational evaluators. The outline is divided into…
Standardizing Quality Assessment of Fused Remotely Sensed Images
NASA Astrophysics Data System (ADS)
Pohl, C.; Moellmann, J.; Fries, K.
2017-09-01
The multitude of available operational remote sensing satellites led to the development of many image fusion techniques to provide high spatial, spectral and temporal resolution images. The comparison of different techniques is necessary to obtain an optimized image for the different applications of remote sensing. There are two approaches in assessing image quality: 1. Quantitatively by visual interpretation and 2. Quantitatively using image quality indices. However an objective comparison is difficult due to the fact that a visual assessment is always subject and a quantitative assessment is done by different criteria. Depending on the criteria and indices the result varies. Therefore it is necessary to standardize both processes (qualitative and quantitative assessment) in order to allow an objective image fusion quality evaluation. Various studies have been conducted at the University of Osnabrueck (UOS) to establish a standardized process to objectively compare fused image quality. First established image fusion quality assessment protocols, i.e. Quality with No Reference (QNR) and Khan's protocol, were compared on varies fusion experiments. Second the process of visual quality assessment was structured and standardized with the aim to provide an evaluation protocol. This manuscript reports on the results of the comparison and provides recommendations for future research.
Cost-effectiveness of the streamflow-gaging program in Wyoming
Druse, S.A.; Wahl, K.L.
1988-01-01
This report documents the results of a cost-effectiveness study of the streamflow-gaging program in Wyoming. Regression analysis or hydrologic flow-routing techniques were considered for 24 combinations of stations from a 139-station network operated in 1984 to investigate suitability of techniques for simulating streamflow records. Only one station was determined to have sufficient accuracy in the regression analysis to consider discontinuance of the gage. The evaluation of the gaging-station network, which included the use of associated uncertainty in streamflow records, is limited to the nonwinter operation of the 47 stations operated by the Riverton Field Office of the U.S. Geological Survey. The current (1987) travel routes and measurement frequencies require a budget of $264,000 and result in an average standard error in streamflow records of 13.2%. Changes in routes and station visits using the same budget, could optimally reduce the standard error by 1.6%. Budgets evaluated ranged from $235,000 to $400,000. A $235,000 budget increased the optimal average standard error/station from 11.6 to 15.5%, and a $400,000 budget could reduce it to 6.6%. For all budgets considered, lost record accounts for about 40% of the average standard error. (USGS)
Numeric data distribution: The vital role of data exchange in today's world
NASA Technical Reports Server (NTRS)
Chase, Malcolm W.
1994-01-01
The major aim of the NIST standard Reference Data Program (SRD) is to provide critically evaluated numeric data to the scientific and technical community in a convenient and accessible form. A second aim of the program is to provide feedback into the experimental and theoretical programs to help raise the general standards of measurement. By communicating the experience gained in evaluating the world output of data in the physical sciences, NIST/SRD helps to advance the level of experimental techniques and improve the reliability of physical measurements.
Black, James C; Ricci, William M; Gardner, Michael J; McAndrew, Christopher M; Agarwalla, Avinesh; Wojahn, Robert D; Abar, Orchid; Tang, Simon Y
2016-12-01
Patellar tendon ruptures commonly are repaired using transosseous patellar drill tunnels with modified-Krackow sutures in the patellar tendon. This simple suture technique has been associated with failure rates and poor clinical outcomes in a modest proportion of patients. Failure of this repair technique can result from gap formation during loading or a single catastrophic event. Several augmentation techniques have been described to improve the integrity of the repair, but standardized biomechanical evaluation of repair strength among different techniques is lacking. The purpose of this study was to describe a novel figure-of-eight suture technique to augment traditional fixation and evaluate its biomechanical performance. We hypothesized that the augmentation technique would (1) reduce gap formation during cyclic loading and (2) increase the maximum load to failure. Ten pairs (two male, eight female) of fresh-frozen cadaveric knees free of overt disorders or patellar tendon damage were used (average donor age, 76 years; range, 65-87 years). For each pair, one specimen underwent the standard transosseous tunnel suture repair with a modified-Krackow suture technique and the second underwent the standard repair with our experimental augmentation method. Nine pairs were suitable for testing. Each specimen underwent cyclic loading while continuously measuring gap formation across the repair. At the completion of cyclic loading, load to failure testing was performed. A difference in gap formation and mean load to failure was seen in favor of the augmentation technique. At 250 cycles, a 68% increase in gap formation was seen for the control group (control: 5.96 ± 0.86 mm [95% CI, 5.30-6.62 mm]; augmentation: 3.55 ± 0.56 mm [95% CI, 3.12-3.98 mm]; p = 0.02). The mean load to failure was 13% greater in the augmentation group (control: 899.57 ± 96.94 N [95% CI, 825.06-974.09 N]; augmentation: 1030.70 ± 122.41 N [95% CI, 936.61-1124.79 N]; p = 0.01). This biomechanical study showed improved performance of a novel augmentation technique compared with the standard repair, in terms of reduced gap formation during cyclic loading and increased maximum load to failure. Decreased gap formation and higher load to failure may improve healing potential and minimize failure risk. This study shows a potential biomechanical advantage of the augmentation technique, providing support for future clinical investigations comparing this technique with other repair methods that are in common use such as transosseous suture repair.
Mosavi, Firas; Laurell, Anna; Ahlström, Håkan
2015-11-01
Whole body (WB) magnetic resonance imaging (MRI), including diffusion-weighted imaging (DWI) has become increasingly utilized in cancer imaging, yet the clinical utility of these techniques in follow-up of testicular cancer patients has not been evaluated. The purpose of this study was to evaluate the feasibility of WB MRI with continuous table movement (CTM) technique, including multistep DWI in follow-up of patients with testicular cancer. WB MRI including DWI was performed in follow-up of 71 consecutive patients (median age, 37 years; range 19-84) with histologically confirmed testicular cancer. WB MRI protocol included axial T1-Dixon and T2-BLADE sequences using CTM technique. Furthermore, multi-step DWI was performed using b-value 50 and 1000 s/mm(2). One criterion for feasibility was patient tolerance and satisfactory image quality. Another criterion was the accuracy in detection of any pathological mass, compared to standard of reference. Signal intensity in DWI was used for evaluation of residual mass activity. Clinical, laboratory and imaging follow-up were applied as standard of reference for the evaluation of WB MRI. WB MRI was tolerated in nearly all patients (69/71 patients, 97%) and the image quality was satisfactory. Metal artifacts deteriorated the image quality in six patients, but it did not influence the overall results. No case of clinical relapse was observed during the follow-up time. There was a good agreement between conventional WB MRI and standard of reference in all patients. Three patients showed residual masses and DWI signal was not restricted in these patients. Furthermore, DWI showed abnormally high signal intensity in a normal-sized retroperitoneal lymph node indicating metastasis. The subsequent (18)F-FDG PET/CT could verify the finding. WB MRI with CTM technique including multi-step DWI is feasible in follow-up of patients with testicular cancer. DWI may contribute to important added-value data to conventional MRI sequences regarding the activity of residual masses.
NASA Astrophysics Data System (ADS)
Vanvyve, E.; Magontier, P.; Vandenberghe, F. C.; Delle Monache, L.; Dickinson, K.
2012-12-01
Wind energy is amongst the fastest growing sources of renewable energy in the U.S. and could supply up to 20 % of the U.S power production by 2030. An accurate and reliable wind resource assessment for prospective wind farm sites is a challenging task, yet is crucial for evaluating the long-term profitability and feasibility of a potential development. We have developed an accurate and computationally efficient wind resource assessment technique for prospective wind farm sites, which incorporates innovative statistical techniques and the new NASA Earth science dataset MERRA. This technique produces a wind resource estimate that is more accurate than that obtained by the wind energy industry's standard technique, while providing a reliable quantification of its uncertainty. The focus now is on evaluating the socio-economic value of this new technique upon using the industry's standard technique. Would it yield lower financing costs? Could it result in lower electricity prices? Are there further down-the-line positive consequences, e.g. job creation, time saved, greenhouse gas decrease? Ultimately, we expect our results will inform efforts to refine and disseminate the new technique to support the development of the U.S. renewable energy infrastructure. In order to address the above questions, we are carrying out a cost-benefit analysis based on the net present worth of the technique. We will describe this approach, including the cash-flow process of wind farm financing, how the wind resource assessment factors in, and will present current results for various hypothetical candidate wind farm sites.
Zeynoddin, Mohammad; Bonakdari, Hossein; Azari, Arash; Ebtehaj, Isa; Gharabaghi, Bahram; Riahi Madavar, Hossein
2018-09-15
A novel hybrid approach is presented that can more accurately predict monthly rainfall in a tropical climate by integrating a linear stochastic model with a powerful non-linear extreme learning machine method. This new hybrid method was then evaluated by considering four general scenarios. In the first scenario, the modeling process is initiated without preprocessing input data as a base case. While in other three scenarios, the one-step and two-step procedures are utilized to make the model predictions more precise. The mentioned scenarios are based on a combination of stationarization techniques (i.e., differencing, seasonal and non-seasonal standardization and spectral analysis), and normality transforms (i.e., Box-Cox, John and Draper, Yeo and Johnson, Johnson, Box-Cox-Mod, log, log standard, and Manly). In scenario 2, which is a one-step scenario, the stationarization methods are employed as preprocessing approaches. In scenario 3 and 4, different combinations of normality transform, and stationarization methods are considered as preprocessing techniques. In total, 61 sub-scenarios are evaluated resulting 11013 models (10785 linear methods, 4 nonlinear models, and 224 hybrid models are evaluated). The uncertainty of the linear, nonlinear and hybrid models are examined by Monte Carlo technique. The best preprocessing technique is the utilization of Johnson normality transform and seasonal standardization (respectively) (R 2 = 0.99; RMSE = 0.6; MAE = 0.38; RMSRE = 0.1, MARE = 0.06, UI = 0.03 &UII = 0.05). The results of uncertainty analysis indicated the good performance of proposed technique (d-factor = 0.27; 95PPU = 83.57). Moreover, the results of the proposed methodology in this study were compared with an evolutionary hybrid of adaptive neuro fuzzy inference system (ANFIS) with firefly algorithm (ANFIS-FFA) demonstrating that the new hybrid methods outperformed ANFIS-FFA method. Copyright © 2018 Elsevier Ltd. All rights reserved.
Benson, Sarah J; Lennard, Christopher J; Hill, David M; Maynard, Philip; Roux, Claude
2010-01-01
A significant amount of research has been conducted into the use of stable isotopes to assist in determining the origin of various materials. The research conducted in the forensic field shows the potential of isotope ratio mass spectrometry (IRMS) to provide a level of discrimination not achievable utilizing traditional forensic techniques. Despite the research there have been few, if any, publications addressing the validation and measurement uncertainty of the technique for forensic applications. This study, the first in a planned series, presents validation data for the measurement of bulk nitrogen isotope ratios in ammonium nitrate (AN) using the DELTA(plus)XP (Thermo Finnigan) IRMS instrument equipped with a ConFlo III interface and FlashEA 1112 elemental analyzer (EA). Appropriate laboratory standards, analytical methods and correction calculations were developed and evaluated. A validation protocol was developed in line with the guidelines provided by the National Association of Testing Authorities, Australia (NATA). Performance characteristics including: accuracy, precision/repeatability, reproducibility/ruggedness, robustness, linear range, and measurement uncertainty were evaluated for the measurement of nitrogen isotope ratios in AN. AN (99.5%) and ammonium thiocyanate (99.99+%) were determined to be the most suitable laboratory standards and were calibrated against international standards (certified reference materials). All performance characteristics were within an acceptable range when potential uncertainties, including the manufacturer's uncertainty of the technique and standards, were taken into account. The experiments described in this article could be used as a model for validation of other instruments for similar purposes. Later studies in this series will address the more general issue of demonstrating that the IRMS technique is scientifically sound and fit-for-purpose in the forensic explosives analysis field.
Research on evaluation and standardization of accelerated bridge construction techniques, part II.
DOT National Transportation Integrated Search
2015-09-01
The Michigan Department of Transportation (MDOT) uses Accelerated bridge construction : (ABC) to reduce delays and minimize construction impacts. MDOT contracted and completed : several bridges using prefabricated bridge elements and systems (PBES). ...
Research on evaluation and standardization of accelerated bridge construction techniques, part I.
DOT National Transportation Integrated Search
2015-09-01
The Michigan Department of Transportation (MDOT) uses Accelerated bridge construction : (ABC) to reduce delays and minimize construction impacts. MDOT contracted and completed : several bridges using prefabricated bridge elements and systems (PBES). ...
A comparative physical evaluation of four X-ray films.
Egyed, M; Shearer, D R
1981-09-01
In this study, four general purpose radiographic films (Agfa Gevaert Curix RP-1, duPont Cronex 4, Fuji RX, and Kodak XRP-1) were compared using three independent techniques. By examining the characteristic curves for the four films, film speed and contrast were compared over the diagnostically useful density range. These curves were generated using three methods: (1) irradiation of a standard film cassette lined with high-speed screens, covered by a twelve-step aluminum wedge; (2) direct exposure of film strips to an electro-luminescent sensitometer; and (3) direct irradiation of a standard film cassette lined with high-speed screens. The latter technique provided quantitative values for film speed and relative contrast. All three techniques provided virtually properly identical results and indicate that under properly controlled conditions simplified methods of film testing can give results equivalent to those obtained by more sophisticated techniques.
Jay, Raman; Heckman, J E; Hinshaw, L; Best, S; Lubner, M; Jarrard, D F; Downs, T M; Nakada, S Y; Lee, F T; Huang, W; Ziemlewicz, T
2017-03-01
Percutaneous biopsy obtained from a single location is prone to sampling error in large heterogeneous renal masses, leading to nondiagnostic results or failure to detect poor prognostic features. We evaluated the accuracy of percutaneous biopsy for large renal masses using a modified multi-quadrant technique vs. a standard biopsy technique. Clinical and pathological data for all patients with cT2 or greater renal masses who underwent percutaneous biopsy from 2009 to 2014 were reviewed. The multi-quadrant technique was defined as multiple core biopsies from at least 4 separate solid enhancing areas in the tumor. The incidence of nondiagnostic findings, sarcomatoid features and procedural complications was recorded, and concordance between biopsy specimens and nephrectomy pathology was compared. A total of 122 biopsies were performed for 117 tumors in 116 patients (46 using the standard biopsy technique and 76 using the multi-quadrant technique). Median tumor size was 10cm (IQR: 8-12). Biopsy was nondiagnostic in 5 of 46 (10.9%) standard and 0 of 76 (0%) multi-quadrant biopsies (P = 0.007). Renal cell carcinoma was identified in 96 of 115 (82.0%) tumors and nonrenal cell carcinoma tumors were identified in 21 (18.0%). One complication occurred using the standard biopsy technique and no complications were reported using the multi-quadrant technique. Sarcomatoid features were present in 23 of 96 (23.9%) large renal cell carcinomas studied. Sensitivity for identifying sarcomatoid features was higher using the multi-quadrant technique compared to the standard biopsy technique at 13 of 15 (86.7%) vs. 2 of 8 (25.0%) (P = 0.0062). The multi-quadrant percutaneous biopsy technique increases the ability to identify aggressive pathological features in large renal tumors and decreases nondiagnostic biopsy rates. Copyright © 2017. Published by Elsevier Inc.
Rigatelli, Gianluca; Zuin, Marco; Dell'Avvocata, Fabio; Cardaioli, Paolo; Vassiliev, Dobrin; Ferenc, Miroslaw; Nghia, Nguyen Tuan; Nguyen, Thach; Foin, Nicholas
2018-04-01
Multiple BRSs and specifically the Absorb scaffold (BVS) (Abbott Vascular, Santa Clara, CA USA) have been often used to treat long diffuse coronary artery lesions. We evaluate by a computational fluid dynamic(CFD) study the impact on the intravascular fluid rheology on multiple bioabsorbable scaffolds (BRS) by standard overlapping versus edge-to-edge technique. We simulated the treatment of a real long significant coronary lesion (>70% luminal narrowing) involving the left anterior descending artery (LAD) treated with a standard or edge-to-edge technique, respectively. Simulations were performed after BVS implantations in two different conditions: 1) Edge-to-edge technique, where the scaffolds are kissed but not overlapped resulting in a luminal encroachment of 0.015cm (150μm); 2) Standard overlapping, where the scaffolds are overlapped resulting in a luminal encroachment of 0.030cm (300μm). After positioning the BVS across the long lesion, the implantation procedure was performed in-silico following all the usual procedural steps. Analysis of the wall shear stress (WSS) suggested that at the vessel wall level the WSS were lower in the overlapping zones overlapping compared to the edge-to-edge zone (∆=0.061Pa, p=0.01). At the struts level the difference between the two WSS was more striking (∆=1.065e-004 p=0.01) favouring the edge-to-edge zone. Our study suggested that at both vessel wall and scaffold struts levels, there was lowering WSS when multiple BVS were implanted with the standard overlapping technique compared to the "edge-to-edge" technique. This lower WSS might represent a substrate for restenosis, early and late BVS thrombosis, potentially explaining at least in part the recent evidences of devices poor performance. Copyright © 2017 Elsevier Inc. All rights reserved.
Multiparametric prostate MRI: technical conduct, standardized report and clinical use.
Manfredi, Matteo; Mele, Fabrizio; Garrou, Diletta; Walz, Jochen; Fütterer, Jurgen J; Russo, Filippo; Vassallo, Lorenzo; Villers, Arnauld; Emberton, Mark; Valerio, Massimo
2018-02-01
Multiparametric prostate MRI (mp-MRI) is an emerging imaging modality for diagnosis, characterization, staging, and treatment planning of prostate cancer (PCa). The technique, results reporting, and its role in clinical practice have been the subject of significant development over the last decade. Although mp-MRI is not yet routinely used in the diagnostic pathway, almost all urological guidelines have emphasized the potential role of mp-MRI in several aspects of PCa management. Moreover, new MRI sequences and scanning techniques are currently under evaluation to improve the diagnostic accuracy of mp-MRI. This review presents an overview of mp-MRI, summarizing the technical applications, the standardized reporting systems used, and their current roles in various stages of PCa management. Finally, this critical review also reports the main limitations and future perspectives of the technique.
Earthquake prediction evaluation standards applied to the VAN Method
NASA Astrophysics Data System (ADS)
Jackson, David D.
Earthquake prediction research must meet certain standards before it can be suitably evaluated for potential application in decision making. For methods that result in a binary (on or off) alarm condition, requirements include (1) a quantitative description of observables that trigger an alarm, (2) a quantitative description, including ranges of time, location, and magnitude, of the predicted earthquakes, (3) documented evidence of all previous alarms, (4) a complete list of predicted earthquakes, (5) a complete list of unpredicted earthquakes. The VAN technique [Varotsos and Lazaridou, 1991; Varotsos et al., 1996] has not yet been stated as a testable hypothesis. It fails criteria (1) and (2) so it is not ready to be evaluated properly. Although telegrams were transmitted in advance of claimed successes, these telegrams did not fully specify the predicted events, and all of the published statistical evaluations involve many subjective ex post facto decisions. Lacking a statistically demonstrated relationship to earthquakes, a candidate prediction technique should satisfy several plausibility criteria, including: (1) a reasonable relationship between the location of the candidate precursor and that of the predicted earthquake, (2) some demonstration that the candidate precursory observations are related to stress, strain, or other quantities related to earthquakes, and (3) the existence of co-seismic as well as pre-seismic variations of the candidate precursor. The VAN technique meets none of these criteria.
NASA Technical Reports Server (NTRS)
Romanofsky, Robert R.; Shalkhauser, Kurt A.
1989-01-01
The design and evaluation of a novel fixturing technique for characterizing millimeter wave solid state devices is presented. The technique utilizes a cosine-tapered ridge guide fixture and a one-tier de-embedding procedure to produce accurate and repeatable device level data. Advanced features of this technique include nondestructive testing, full waveguide bandwidth operation, universality of application, and rapid, yet repeatable, chip-level characterization. In addition, only one set of calibration standards is required regardless of the device geometry.
ERIC Educational Resources Information Center
Beasley, Jennifer G.; Briggs, Christine; Pennington, Leighann
2017-01-01
The need for a shared vision concerning exemplary curricula for academically advanced learners must be a priority in the field of education. With the advent of the Common Core State Standards adoption in many states, a new conversation has been ignited over meeting the needs of students with gifts and talents for whom the "standard"…
Collé, R.; Zimmerman, B. E.
1997-01-01
The National Institute of Standards and Technology recently participated in an international measurement intercomparison for 63Ni and 55Fe, which was conducted amongst principal national radionuclidic metrology laboratories. The intercomparison was sponsored by EUROMET, and was primarily intended to evaluate the capabilities of liquid scintillation (LS) spectrometry techniques for standardizing nuclides that decay by low-energy β-emission (like 63Ni) and by low-Z (atomic number) electron capture (like 55Fe). The intercomparison findings exhibit a very good agreement for 63Ni amongst the various participating laboratories, including that for NIST, which suggests that the presently invoked LS methodologies are very capable of providing internationally-compatible standardizations for low-energy β-emitters. The results for 55Fe are in considerably poorer agreement, and demonstrated the existence of several unresolved problems. It has thus become apparent that there is a need for the various international laboratories to conduct rigorous, systematic evaluations of their LS capabilities in assaying radionuclides that decay by low-Z electron capture. PMID:27805141
Duct Leakage Repeatability Testing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walker, Iain; Sherman, Max
2014-08-01
The purpose of this report is to evaluate the repeatability of the three most significant measurement techniques for duct leakage using data from the literature and recently obtained field data. We will also briefly discuss the first two factors. The main question to be answered by this study is to determine if differences in the repeatability of these tests methods is sufficient to indicate that any of these methods is so poor that it should be excluded from consideration as an allowed procedure in codes and standards. The three duct leak measurement methods assessed in this report are the twomore » duct pressurization methods that are commonly used by many practitioners and the DeltaQ technique. These are methods B, C and A, respectively of the ASTM E1554 standard. Although it would be useful to evaluate other duct leak test methods, this study focused on those test methods that are commonly used and are required in various test standards, such as BPI (2010), RESNET (2014), ASHRAE 62.2 (2013), California Title 24 (CEC 2012), DOE Weatherization and many other energy efficiency programs.« less
Evaluation of standard methods for collecting and processing fuel moisture samples
Sally M. Haase; José Sánchez; David R. Weise
2016-01-01
A variety of techniques for collecting and processing samples to determine moisture content of wildland fuels in support of fire management activities were evaluated. The effects of using a chainsaw or handsaw to collect samples of largediameter wood, containers for storing and transporting collected samples, and quick-response ovens for estimating moisture content...
ABSTRACT Aims This study developed and systematically evaluated performance and limit of detection of an off-the-slide genotyping procedure for both Cryptosporidium oocysts and Giardia cysts. Methods and Results Slide standards containing flow sorted (oo)cysts were used to e...
Development of evaluation technique of GMAW welding quality based on statistical analysis
NASA Astrophysics Data System (ADS)
Feng, Shengqiang; Terasaki, Hidenri; Komizo, Yuichi; Hu, Shengsun; Chen, Donggao; Ma, Zhihua
2014-11-01
Nondestructive techniques for appraising gas metal arc welding(GMAW) faults plays a very important role in on-line quality controllability and prediction of the GMAW process. On-line welding quality controllability and prediction have several disadvantages such as high cost, low efficiency, complication and greatly being affected by the environment. An enhanced, efficient evaluation technique for evaluating welding faults based on Mahalanobis distance(MD) and normal distribution is presented. In addition, a new piece of equipment, designated the weld quality tester(WQT), is developed based on the proposed evaluation technique. MD is superior to other multidimensional distances such as Euclidean distance because the covariance matrix used for calculating MD takes into account correlations in the data and scaling. The values of MD obtained from welding current and arc voltage are assumed to follow a normal distribution. The normal distribution has two parameters: the mean µ and standard deviation σ of the data. In the proposed evaluation technique used by the WQT, values of MD located in the range from zero to µ+3 σ are regarded as "good". Two experiments which involve changing the flow of shielding gas and smearing paint on the surface of the substrate are conducted in order to verify the sensitivity of the proposed evaluation technique and the feasibility of using WQT. The experimental results demonstrate the usefulness of the WQT for evaluating welding quality. The proposed technique can be applied to implement the on-line welding quality controllability and prediction, which is of great importance to design some novel equipment for weld quality detection.
Design and Control of Chemical Grouting : Volume 1 - Construction Control
DOT National Transportation Integrated Search
1983-04-01
This report presents the results of a laboratory and field research program investigating innovative method for design and control of chemical grouting in soils. Chemical grouting practice is reviewed and standard evaluation and measurement technique...
PARTICLE ASSOCIATION EFFECTS ON MICROBIAL INDICATOR CONCENTRATIONS AND CSO DISINFECTION
Combined sewer overflow (CSO) and wastewater disinfection effectiveness are evaluated by measuring microbial indicator concentrations before and after disinfection. The standard techniques for quantifying indicators are membrane filtration and multiple-tube fermentation/most pro...
Chemical vapor deposition growth
NASA Technical Reports Server (NTRS)
Ruth, R. P.; Manasevit, H. M.; Campbell, A. G.; Johnson, R. E.; Kenty, J. L.; Moudy, L. A.; Shaw, G. L.; Simpson, W. I.; Yang, J. J.
1978-01-01
The objective was to investigate and develop chemical vapor deposition (CVD) techniques for the growth of large areas of Si sheet on inexpensive substrate materials, with resulting sheet properties suitable for fabricating solar cells that would meet the technical goals of the Low Cost Silicon Solar Array Project. The program involved six main technical tasks: (1) modification and test of an existing vertical-chamber CVD reactor system; (2) identification and/or development of suitable inexpensive substrate materials; (3) experimental investigation of CVD process parameters using various candidate substrate materials; (4) preparation of Si sheet samples for various special studies, including solar cell fabrication; (5) evaluation of the properties of the Si sheet material produced by the CVD process; and (6) fabrication and evaluation of experimental solar cell structures, using impurity diffusion and other standard and near-standard processing techniques supplemented late in the program by the in situ CVD growth of n(+)/p/p(+) sheet structures subsequently processed into experimental cells.
Henrionnet, Christel; Dumas, Dominique; Hupont, Sébastien; Stoltz, Jean François; Mainard, Didier; Gillet, Pierre; Pinzano, Astrid
2017-01-01
In tissue engineering approaches, the quality of substitutes is a key element to determine its ability to treat cartilage defects. However, in clinical practice, the evaluation of tissue-engineered cartilage substitute quality is not possible due to the invasiveness of the standard procedure, which is to date histology. The aim of this work was to validate a new innovative system performed from two-photon excitation laser adapted to an optical macroscope to evaluate at macroscopic scale the collagen network in cartilage tissue-engineered substitutes in confrontation with gold standard histologic techniques or immunohistochemistry to visualize type II collagen. This system permitted to differentiate the quality of collagen network between ITS and TGF-β1 treatments. Multiscale large field imaging combined to multimodality approaches (SHG-TCSPC) at macroscopical scale represent an innovative and non-invasive technique to monitor the quality of collagen network in cartilage tissue-engineered substitutes before in vivo implantation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lundstrom, B.; Shirazi, M.; Coddington, M.
2013-02-01
This poster describes a Grid Interconnection System Evaluator (GISE) that leverages hardware-in-the-loop (HIL) simulation techniques to rapidly evaluate the grid interconnection standard conformance of an ICS according to the procedures in IEEE Std 1547.1TM. The architecture and test sequencing of this evaluation tool, along with a set of representative ICS test results from three different photovoltaic (PV) inverters, are presented. The GISE adds to the National Renewable Energy Laboratory's (NREL) evaluation platform that now allows for rapid development of ICS control algorithms using controller HIL (CHIL) techniques, the ability to test the dc input characteristics of PV-based ICSs through themore » use of a PV simulator capable of simulating real-world dynamics using power HIL (PHIL), and evaluation of ICS grid interconnection conformance.« less
Effects of Vibration Therapy in Pediatric Immunizations.
Benjamin, Arika L; Hendrix, Thomas J; Woody, Jacque L
2016-01-01
A randomized clinical trial of 100 children (52 boys, 48 girls) ages 2 months to 7 years was conducted to evaluate the effect of vibration therapy without cold analgesia on pain. A convenience sample was recruited at two sites: a publicly funded, free immunization clinic and a private group pediatric practice. Participants were randomly assigned to receive vibration therapy via a specialized vibrating device or standard care. All children regardless of intervention group were allowed to be distracted and soothed by the parent. Pain was evaluated using the FLACC score, which two nurses assessed at three points in time: prior to, during, and after the injection(s). Data were analyzed using a two-independent samples-paired t-test. Results show that vibration therapy had no effect on pain scores in the younger age groups studied (2 months ≤ 1 year, > 1 year ≤ 4 years). In the oldest age group (> 4 to 7 years of age), a heightened pain reading was found in the period from preinjection to post-injection periods (p = 0.045). These results indicate that the addition of vibration therapy (without cold analgesia) to standard soothing techniques is no more effective in reducing immunization pain than standard soothing techniques alone, and thus, is not indicated for use with immunization pain. Recommendations include further evaluation of interventions.
[Comparative study of the biometric measurements made by immersion and contact techniques].
Kronbauer, Airton Leite; Kronbauer, Fernando Leite; Kronbauer, Cláudia Leite
2006-01-01
To compare clinical biometric findings between measurements of immersion technique and contact technique. Axial length was measured by A-scan in 120 medical examinations in 60 patients with cataract using a non-contact (immersion) and a contact technique in paired-samples by ultrasound. The mean axial length was found to be 23.19 mm (SD 1.32) with the immersion technique and 22.93 mm (SD 1.32) with the contact technique, using the same transducer probe. The difference of 0.255 mm (SD 0.3) was significant at the 0.01 level. The difference should be taken into account when evaluating the accuracy of IOL calculation. The mean standard deviation between recurrent measures in same eye was found to be 0.04 with the immersion technique and 0.19 with the contact technique. The difference of 0.15 was significant at the 0.01 level. The difference should be taken into account when evaluating the accuracy of reproductivity of technique examination. These data provide benchmark information that can be used to monitor clinical practice and to perform others studies.
Comparative hazard evaluation of near-infrared diode lasers.
Marshall, W J
1994-05-01
Hazard evaluation methods from various laser protection standards differ when applied to extended-source, near-infrared lasers. By way of example, various hazard analyses are applied to laser training systems, which incorporate diode lasers, specifically those that assist in training military or law enforcement personnel in the proper use of weapons by simulating actual firing by the substitution of a beam of near-infrared energy for bullets. A correct hazard evaluation of these lasers is necessary since simulators are designed to be directed toward personnel during normal use. The differences among laser standards are most apparent when determining the hazard class of a laser. Hazard classification is based on a comparison of the potential exposures with the maximum permissible exposures in the 1986 and 1993 versions of the American National Standard for the Safe Use of Lasers, Z136.1, and the accessible emission limits of the federal laser product performance standard. Necessary safety design features of a particular system depend on the hazard class. The ANSI Z136.1-1993 standard provides a simpler and more accurate hazard assessment of low-power, near-infrared, diode laser systems than the 1986 ANSI standard. Although a specific system is evaluated, the techniques described can be readily applied to other near-infrared lasers or laser training systems.
Dugdale, Stephanie; Ward, Jonathan; Hernen, Jan; Elison, Sarah; Davies, Glyn; Donkor, Daniel
2016-07-22
In recent years, research within the field of health psychology has made significant progress in terms of advancing and standardizing the science of developing, evaluating and reporting complex behavioral change interventions. A major part of this work has involved the development of an evidence-based Behavior Change Technique Taxonomy v1 (BCTTv1), as a means of describing the active components contained within such complex interventions. To date, however, this standardized approach derived from health psychology research has not been applied to the development of complex interventions for the treatment of substance use disorders (SUD). Therefore, this paper uses Breaking Free Online (BFO), a computer-assisted therapy program for SUD, as an example of how the clinical techniques contained within such an intervention might be mapped onto the BCTTv1. The developers of BFO were able to produce a full list of the clinical techniques contained within BFO. Exploratory mapping of the BCTTv1 onto the clinical content of the BFO program was conducted separately by the authors of the paper. This included the developers of the BFO program and psychology professionals working within the SUD field. These coded techniques were reviewed by the authors and any discrepancies in the coding were discussed between all authors until an agreement was reached. The BCTTv1 was mapped onto the clinical content of the BFO program. At least one behavioral change technique was found in 12 out of 16 grouping categories within the BCTTv1. A total of 26 out of 93 behavior change techniques were identified across the clinical content of the program. This exploratory mapping exercise has identified the specific behavior change techniques contained within BFO, and has provided a means of describing these techniques in a standardized way using the BCTTv1 terminology. It has also provided an opportunity for the BCTTv1 mapping process to be reported to the wider SUD treatment community, as it may have real utility in the development and evaluation of other psychosocial and behavioral change interventions within this field.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lundstrom, B.; Shirazi, M.; Coddington, M.
2013-01-01
This paper, presented at the IEEE Green Technologies Conference 2013, describes a Grid Interconnection System Evaluator (GISE) that leverages hardware-in-the-loop (HIL) simulation techniques to rapidly evaluate the grid interconnection standard conformance of an ICS according to the procedures in IEEE Std 1547.1 (TM). The architecture and test sequencing of this evaluation tool, along with a set of representative ICS test results from three different photovoltaic (PV) inverters, are presented. The GISE adds to the National Renewable Energy Laboratory's (NREL) evaluation platform that now allows for rapid development of ICS control algorithms using controller HIL (CHIL) techniques, the ability to testmore » the dc input characteristics of PV-based ICSs through the use of a PV simulator capable of simulating real-world dynamics using power HIL (PHIL), and evaluation of ICS grid interconnection conformance.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lundstrom, B.; Shirazi, M.; Coddington, M.
2013-01-01
This paper describes a Grid Interconnection System Evaluator (GISE) that leverages hardware-in-the-loop (HIL) simulation techniques to rapidly evaluate the grid interconnection standard conformance of an ICS according to the procedures in IEEE Std 1547.1. The architecture and test sequencing of this evaluation tool, along with a set of representative ICS test results from three different photovoltaic (PV) inverters, are presented. The GISE adds to the National Renewable Energy Laboratory's (NREL) evaluation platform that now allows for rapid development of ICS control algorithms using controller HIL (CHIL) techniques, the ability to test the dc input characteristics of PV-based ICSs through themore » use of a PV simulator capable of simulating real-world dynamics using power HIL (PHIL), and evaluation of ICS grid interconnection conformance.« less
Computer-Assisted Digital Image Analysis of Plus Disease in Retinopathy of Prematurity.
Kemp, Pavlina S; VanderVeen, Deborah K
2016-01-01
The objective of this study is to review the current state and role of computer-assisted analysis in diagnosis of plus disease in retinopathy of prematurity. Diagnosis and documentation of retinopathy of prematurity are increasingly being supplemented by digital imaging. The incorporation of computer-aided techniques has the potential to add valuable information and standardization regarding the presence of plus disease, an important criterion in deciding the necessity of treatment of vision-threatening retinopathy of prematurity. A review of literature found that several techniques have been published examining the process and role of computer aided analysis of plus disease in retinopathy of prematurity. These techniques use semiautomated image analysis techniques to evaluate retinal vascular dilation and tortuosity, using calculated parameters to evaluate presence or absence of plus disease. These values are then compared with expert consensus. The study concludes that computer-aided image analysis has the potential to use quantitative and objective criteria to act as a supplemental tool in evaluating for plus disease in the setting of retinopathy of prematurity.
Gilabert-Perramon, Antoni; Torrent-Farnell, Josep; Catalan, Arancha; Prat, Alba; Fontanet, Manel; Puig-Peiró, Ruth; Merino-Montero, Sandra; Khoury, Hanane; Goetghebeur, Mireille M; Badia, Xavier
2017-01-01
The aim of this study was to adapt and assess the value of a Multi-Criteria Decision Analysis (MCDA) framework (EVIDEM) for the evaluation of Orphan drugs in Catalonia (Catalan Health Service). The standard evaluation and decision-making procedures of CatSalut were compared with the EVIDEM methodology and contents. The EVIDEM framework was adapted to the Catalan context, focusing on the evaluation of Orphan drugs (PASFTAC program), during a Workshop with sixteen PASFTAC members. The criteria weighting was done using two different techniques (nonhierarchical and hierarchical). Reliability was assessed by re-test. The EVIDEM framework and methodology was found useful and feasible for Orphan drugs evaluation and decision making in Catalonia. All the criteria considered for the development of the CatSalut Technical Reports and decision making were considered in the framework. Nevertheless, the framework could improve the reporting of some of these criteria (i.e., "unmet needs" or "nonmedical costs"). Some Contextual criteria were removed (i.e., "Mandate and scope of healthcare system", "Environmental impact") or adapted ("population priorities and access") for CatSalut purposes. Independently of the weighting technique considered, the most important evaluation criteria identified for orphan drugs were: "disease severity", "unmet needs" and "comparative effectiveness", while the "size of the population" had the lowest relevance for decision making. Test-retest analysis showed weight consistency among techniques, supporting reliability overtime. MCDA (EVIDEM framework) could be a useful tool to complement the current evaluation methods of CatSalut, contributing to standardization and pragmatism, providing a method to tackle ethical dilemmas and facilitating discussions related to decision making.
Yuzbasioglu, Emir; Kurt, Hanefi; Turunc, Rana; Bilir, Halenur
2014-01-30
The purpose of this study was to compare two impression techniques from the perspective of patient preferences and treatment comfort. Twenty-four (12 male, 12 female) subjects who had no previous experience with either conventional or digital impression participated in this study. Conventional impressions of maxillary and mandibular dental arches were taken with a polyether impression material (Impregum, 3 M ESPE), and bite registrations were made with polysiloxane bite registration material (Futar D, Kettenbach). Two weeks later, digital impressions and bite scans were performed using an intra-oral scanner (CEREC Omnicam, Sirona). Immediately after the impressions were made, the subjects' attitudes, preferences and perceptions towards impression techniques were evaluated using a standardized questionnaire. The perceived source of stress was evaluated using the State-Trait Anxiety Scale. Processing steps of the impression techniques (tray selection, working time etc.) were recorded in seconds. Statistical analyses were performed with the Wilcoxon Rank test, and p < 0.05 was considered significant. There were significant differences among the groups (p < 0.05) in terms of total working time and processing steps. Patients stated that digital impressions were more comfortable than conventional techniques. Digital impressions resulted in a more time-efficient technique than conventional impressions. Patients preferred the digital impression technique rather than conventional techniques.
Measurements of dimethyl sulfide and SO2 during GTE/CITE 3
NASA Technical Reports Server (NTRS)
Ferek, Ronald J.; Hegg, Dean A.
1993-01-01
As part of NASA's Tropospheric Experiment Chemical Instrumentation Test and Evaluation (GTE/CITE 3) Sulfur Gas Intercomparison, we conducted measurements of dimethyl sulfide (DMS) and SO2 using two techniques well suited for sampling from an aircraft due to their simplicity of design. DMS was collected by preconcentration on gold wire preceded by a KOH-impregnated filter oxidant scrubber, and analyzed by gas chromatography with flame photometric detection. SO2 was collected on K2CO3/glycerol-impregnated filters and analyzed by ion chromatography. In blind tests, both techniques produced excellent agreement with National Institutes of Standards and Technology (NIST) standards. For field measurements, the DMS technique produced excellent correlation with the mean of the six different techniques intercompared. For SO2, the five techniques intercompared were rather poorly correlated, but correlations between the three techniques which passed NIST standards tests were somewhat better. Our SO2 filter measurements exhibited rather large uncertainties due to higher than normal variabiltiy of the filter blanks, which we believe was caused by extended storage in the field. In measurements conducted off the coast of Natal, Brazil, a diurnal afternoon minimum in DMS concentrations accompanied by a corresponding maximum in SO2 concentrations was observed. However, due to rather large uncertainties in the SO2 measurements, any conclusions about the SO2 trend must by considered tentative.
Integrating multisource land use and land cover data
Wright, Bruce E.; Tait, Mike; Lins, K.F.; Crawford, J.S.; Benjamin, S.P.; Brown, Jesslyn F.
1995-01-01
As part of the U.S. Geological Survey's (USGS) land use and land cover (LULC) program, the USGS in cooperation with the Environmental Systems Research Institute (ESRI) is collecting and integrating LULC data for a standard USGS 1:100,000-scale product. The LULC data collection techniques include interpreting spectrally clustered Landsat Thematic Mapper (TM) images; interpreting 1-meter resolution digital panchromatic orthophoto images; and, for comparison, aggregating locally available large-scale digital data of urban areas. The area selected is the Vancouver, WA-OR quadrangle, which has a mix of urban, rural agriculture, and forest land. Anticipated products include an integrated LULC prototype data set in a standard classification scheme referenced to the USGS digital line graph (DLG) data of the area and prototype software to develop digital LULC data sets.This project will evaluate a draft standard LULC classification system developed by the USGS for use with various source material and collection techniques. Federal, State, and local governments, and private sector groups will have an opportunity to evaluate the resulting prototype software and data sets and to provide recommendations. It is anticipated that this joint research endeavor will increase future collaboration among interested organizations, public and private, for LULC data collection using common standards and tools.
The report gives results of a study of eight houses throughout their construction in. orth Central Florida. ach house was built in compliance with the proposed radon resistant construction standard being developed by the Florida Department of Community Affairs. ach house was moni...
Zhiyong Cai; Michael O. Hunt; Robert J. Ross; Lawrence A. Soltis
1999-01-01
To date, there is no standard method for evaluating the structural integrity of wood floor systems using nondestructive techniques. Current methods of examination and assessment are often subjective and therefore tend to yield imprecise or variable results. For this reason, estimates of allowable wood floor loads are often conservative. The assignment of conservatively...
Kuhn, M A; Burch, M; Chinnock, R E; Fenton, M J
2017-10-01
Intravascular ultrasound (IVUS) has been routinely used in some centers to investigate cardiac allograft vasculopathy in pediatric heart transplant recipients. We present an alternative method using more sophisticated imaging software. This study presents a comparison of this method with an established standard method. All patients who had IVUS performed in 2014 were retrospectively evaluated. The standard technique consisted of analysis of 10 operator-selected segments along the vessel. Each study was re-evaluated using a longitudinal technique, taken at every third cardiac cycle, along the entire vessel. Semiautomatic edge detection software was used to detect vessel imaging planes. Measurements included outer and inner diameter, total and luminal area, maximal intimal thickness (MIT), and intimal index. Each IVUS was graded for severity using the Stanford classification. All results were given as mean ± standard deviation (SD). Groups were compared using Student t test. A P value <.05 was considered significant. There were 59 IVUS studies performed on 58 patients. There was no statistically significant difference between outer diameter, inner diameter, or total area. In the longitudinal group, there was a significantly smaller luminal area, higher MIT, and higher intimal index. Using the longitudinal technique, there was an increase in Stanford classification in 20 patients. The longitudinal technique appeared more sensitive in assessing the degree of cardiac allograft vasculopathy and may play a role in the increase in the degree of thickening seen. It may offer an alternative way of grading severity of cardiac allograft vasculopathy in pediatric heart transplant recipients. Copyright © 2017 Elsevier Inc. All rights reserved.
Liang, Shanshan; Yuan, Fusong; Luo, Xu; Yu, Zhuoren; Tang, Zhihui
2018-04-05
Marginal discrepancy is key to evaluating the accuracy of fixed dental prostheses. An improved method of evaluating marginal discrepancy is needed. The purpose of this in vitro study was to evaluate the absolute marginal discrepancy of ceramic crowns fabricated using conventional and digital methods with a digital method for the quantitative evaluation of absolute marginal discrepancy. The novel method was based on 3-dimensional scanning, iterative closest point registration techniques, and reverse engineering theory. Six standard tooth preparations for the right maxillary central incisor, right maxillary second premolar, right maxillary second molar, left mandibular lateral incisor, left mandibular first premolar, and left mandibular first molar were selected. Ten conventional ceramic crowns and 10 CEREC crowns were fabricated for each tooth preparation. A dental cast scanner was used to obtain 3-dimensional data of the preparations and ceramic crowns, and the data were compared with the "virtual seating" iterative closest point technique. Reverse engineering software used edge sharpening and other functional modules to extract the margins of the preparations and crowns. Finally, quantitative evaluation of the absolute marginal discrepancy of the ceramic crowns was obtained from the 2-dimensional cross-sectional straight-line distance between points on the margin of the ceramic crowns and the standard preparations based on the circumferential function module along the long axis. The absolute marginal discrepancy of the ceramic crowns fabricated using conventional methods was 115 ±15.2 μm, and 110 ±14.3 μm for those fabricated using the digital technique was. ANOVA showed no statistical difference between the 2 methods or among ceramic crowns for different teeth (P>.05). The digital quantitative evaluation method for the absolute marginal discrepancy of ceramic crowns was established. The evaluations determined that the absolute marginal discrepancies were within a clinically acceptable range. This method is acceptable for the digital evaluation of the accuracy of complete crowns. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Medvedovici, Andrei; Albu, Florin; Naşcu-Briciu, Rodica Domnica; Sârbu, Costel
2014-02-01
Discrimination power evaluation of UV-Vis and (±) electrospray ionization/mass spectrometric techniques, (ESI-MS) individually considered or coupled as detectors to reversed phase liquid chromatography (RPLC) in the characterization of Ginkgo Biloba standardized extracts, is used in herbal medicines and/or dietary supplements with the help of Fuzzy hierarchical clustering (FHC). Seventeen batches of Ginkgo Biloba commercially available standardized extracts from seven manufacturers were measured during experiments. All extracts were within the criteria of the official monograph dedicated to dried refined and quantified Ginkgo extracts, in the European Pharmacopoeia. UV-Vis and (±) ESI-MS spectra of the bulk standardized extracts in methanol were acquired. Additionally, an RPLC separation based on a simple gradient elution profile was applied to the standardized extracts. Detection was made through monitoring UV absorption at 220 nm wavelength or the total ion current (TIC) produced through (±) ESI-MS analysis. FHC was applied to raw, centered and scaled data sets, for evaluating the discrimination power of the method with respect to the origins of the extracts and to the batch to batch variability. The discrimination power increases with the increase of the intrinsic selectivity of the spectral technique being used: UV-Vis
Site investigation report mine research project GUE 70-14.10, Guernsey, Ohio.
DOT National Transportation Integrated Search
2003-06-01
Geophysical investigative techniques can be a valuable supplement to standard subsurface investigations for the : evaluation of abandoned underground coal mine workings and their potential impacts at the ground surface. The GUE : 70 - 14.10 Mine Rese...
Fire Safety of Passenger Trains : Phase II : Application of Fire Hazard Analysis Techniques
DOT National Transportation Integrated Search
2001-12-01
On May 12, 1999, the Federal Railroad Administration (FRA) issued regulations for passenger rail equipment safety standards that included small-scale fire tests and performance criteria to evaluate the flammability and smoke characteristics of indivi...
Fire safety of passenger trains. Phase II, Application of fire hazard analysis techniques.
DOT National Transportation Integrated Search
2001-12-01
On May 12, 1999, the Federal Railroad Administration (FRA) issued regulations for passenger rail equipment safety standards that included small-scale fire tests and performance criteria to evaluate the flammability and smoke characteristics of indivi...
Recommended Inorganic Chemicals for Calibration.
ERIC Educational Resources Information Center
Moody, John R.; And Others
1988-01-01
All analytical techniques depend on the use of calibration chemicals to relate analyte concentration to instrumental parameters. Discusses the preparation of standard solutions and provides a critical evaluation of available materials. Lists elements by group and discusses the purity and uses of each. (MVL)
Optimization Based Efficiencies in First Order Reliability Analysis
NASA Technical Reports Server (NTRS)
Peck, Jeffrey A.; Mahadevan, Sankaran
2003-01-01
This paper develops a method for updating the gradient vector of the limit state function in reliability analysis using Broyden's rank one updating technique. In problems that use commercial code as a black box, the gradient calculations are usually done using a finite difference approach, which becomes very expensive for large system models. The proposed method replaces the finite difference gradient calculations in a standard first order reliability method (FORM) with Broyden's Quasi-Newton technique. The resulting algorithm of Broyden updates within a FORM framework (BFORM) is used to run several example problems, and the results compared to standard FORM results. It is found that BFORM typically requires fewer functional evaluations that FORM to converge to the same answer.
Calibration and assessment of full-field optical strain measurement procedures and instrumentation
NASA Astrophysics Data System (ADS)
Kujawinska, Malgorzata; Patterson, E. A.; Burguete, R.; Hack, E.; Mendels, D.; Siebert, T.; Whelan, Maurice
2006-09-01
There are no international standards or norms for the use of optical techniques for full-field strain measurement. In the paper the rationale and design of a reference material and a set of standarized materials for the calibration and evaluation of optical systems for full-field measurements of strain are outlined. A classification system for the steps in the measurement process is also proposed and allows the development of a unified approach to diagnostic testing of components in an optical system for strain measurement based on any optical technique. The results described arise from a European study known as SPOTS whose objectives were to begin to fill the gap caused by a lack of standards.
NASA Technical Reports Server (NTRS)
Wilson, C.; Dye, R.; Reed, L.
1982-01-01
The errors associated with planimetric mapping of the United States using satellite remote sensing techniques are analyzed. Assumptions concerning the state of the art achievable for satellite mapping systems and platforms in the 1995 time frame are made. An analysis of these performance parameters is made using an interactive cartographic satellite computer model, after first validating the model using LANDSAT 1 through 3 performance parameters. An investigation of current large scale (1:24,000) US National mapping techniques is made. Using the results of this investigation, and current national mapping accuracy standards, the 1995 satellite mapping system is evaluated for its ability to meet US mapping standards for planimetric and topographic mapping at scales of 1:24,000 and smaller.
Chianea, Denis; Renard, Christophe; Garcia, Carine; Mbongo, Elvire; Monpeurt, Corine; Vest, Philippe
2010-01-01
The accreditation process, according to NF EN ISO 15189, implies a prior evaluation of the new reagent on-site for the implementation of each new assay technique. Thus, our new standardized method for determination of creatinine (non compensated method) in plasma or serum on UniCel DxC 600 (Beckman Coulter) has been tested according to LAB GTA 04 protocol. The reagent meets the quality criteria recommended by Valtec protocol, except fidelity with the low concentration standard (50 micromol/L). Besides there is no problem of results transferability with the two other techniques used in the laboratory (Jaffe compensated and enzymatic methods performed on Cobas Integra 800).
DeMartini, Wendy B; Ichikawa, Laura; Yankaskas, Bonnie C; Buist, Diana; Kerlikowske, Karla; Geller, Berta; Onega, Tracy; Rosenberg, Robert D; Lehman, Constance D
2010-11-01
MRI is increasingly used for the detection of breast carcinoma. Little is known about breast MRI techniques among community practice facilities. The aim of this study was to evaluate equipment and acquisition techniques used by community facilities across the United States, including compliance with minimum standards by the ACRIN® 6667 Trial and the European Society of Breast Imaging. Breast Cancer Surveillance Consortium facilities performing breast MRI were identified and queried by survey regarding breast MRI equipment and technical parameters. Variables included scanner field strength, coil type, acquisition coverage, slice thickness, and the timing of the initial postcontrast sequence. Results were tallied and percentages of facilities meeting ACRIN® and European Society of Breast Imaging standards were calculated. From 23 facilities performing breast MRI, results were obtained from 14 (61%) facilities with 16 MRI scanners reporting 18 imaging parameters. Compliance with equipment recommendations of ≥1.5-T field strength was 94% and of a dedicated breast coil was 100%. Eighty-three percent of acquisitions used bilateral postcontrast techniques, and 78% used slice thickness≤3 mm. The timing of initial postcontrast sequences ranged from 58 seconds to 8 minutes 30 seconds, with 63% meeting recommendations for completion within 4 minutes. Nearly all surveyed facilities met ACRIN and European Society of Breast Imaging standards for breast MRI equipment. The majority met standards for acquisition parameters, although techniques varied, in particular for the timing of initial postcontrast imaging. Further guidelines by the ACR Breast MRI Accreditation Program will be of importance in facilitating standardized and high-quality breast MRI. Copyright © 2010 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Zweerink, Alwin; Allaart, Cornelis P; Kuijer, Joost P A; Wu, LiNa; Beek, Aernout M; van de Ven, Peter M; Meine, Mathias; Croisille, Pierre; Clarysse, Patrick; van Rossum, Albert C; Nijveldt, Robin
2017-12-01
Although myocardial strain analysis is a potential tool to improve patient selection for cardiac resynchronization therapy (CRT), there is currently no validated clinical approach to derive segmental strains. We evaluated the novel segment length in cine (SLICE) technique to derive segmental strains from standard cardiovascular MR (CMR) cine images in CRT candidates. Twenty-seven patients with left bundle branch block underwent CMR examination including cine imaging and myocardial tagging (CMR-TAG). SLICE was performed by measuring segment length between anatomical landmarks throughout all phases on short-axis cines. This measure of frame-to-frame segment length change was compared to CMR-TAG circumferential strain measurements. Subsequently, conventional markers of CRT response were calculated. Segmental strains showed good to excellent agreement between SLICE and CMR-TAG (septum strain, intraclass correlation coefficient (ICC) 0.76; lateral wall strain, ICC 0.66). Conventional markers of CRT response also showed close agreement between both methods (ICC 0.61-0.78). Reproducibility of SLICE was excellent for intra-observer testing (all ICC ≥0.76) and good for interobserver testing (all ICC ≥0.61). The novel SLICE post-processing technique on standard CMR cine images offers both accurate and robust segmental strain measures compared to the 'gold standard' CMR-TAG technique, and has the advantage of being widely available. • Myocardial strain analysis could potentially improve patient selection for CRT. • Currently a well validated clinical approach to derive segmental strains is lacking. • The novel SLICE technique derives segmental strains from standard CMR cine images. • SLICE-derived strain markers of CRT response showed close agreement with CMR-TAG. • Future studies will focus on the prognostic value of SLICE in CRT candidates.
Bahadori, Mohammadkarim; Ravangard, Ramin; Yaghoubi, Maryam; Alimohammadzadeh, Khalil
2014-01-01
Background: Military hospitals are responsible for preserving, restoring and improving the health of not only armed forces, but also other people. According to the military organizations strategy, which is being a leader and pioneer in all areas, providing quality health services is one of the main goals of the military health care organizations. This study was aimed to evaluate the service quality of selected military hospitals in Iran based on the Joint Commission International (JCI) standards and comparing these hospitals with each other and ranking them using the analytic hierarchy process (AHP) technique in 2013. Materials and Methods: This was a cross-sectional and descriptive study conducted on five military hospitals, selected using the purposive sampling method, in 2013. Required data collected using checklists of accreditation standards and nominal group technique. AHP technique was used for prioritizing. Furthermore, Expert Choice 11.0 was used to analyze the collected data. Results: Among JCI standards, the standards of access to care and continuity of care (weight = 0.122), quality improvement and patient safety (weight = 0.121) and leadership and management (weight = 0.117) had the greatest importance, respectively. Furthermore, in the overall ranking, BGT (weight = 0.369), IHM (0.238), SAU (0.202), IHK (weight = 0.125) and SAB (weight = 0.066) ranked first to fifth, respectively. Conclusion: AHP is an appropriate technique for measuring the overall performance of hospitals and their quality of services. It is a holistic approach that takes all hospital processes into consideration. The results of the present study can be used to improve hospitals performance through identifying areas, which are in need of focus for quality improvement and selecting strategies to improve service quality. PMID:25250364
Thurman, G. B.; Strong, D. M.; Ahmed, A.; Green, S. S.; Sell, K. W.; Hartzman, R. J.; Bach, F. H.
1973-01-01
Use of lymphocyte cultures for in vitro studies such as pretransplant histocompatibility testing has established the need for standardization of this technique. A microculture technique has been developed that has facilitated the culturing of lymphocytes and increased the quantity of cultures feasible, while lowering the variation between replicate samples. Cultures were prepared for determination of tritiated thymidine incorporation using a Multiple Automated Sample Harvester (MASH). Using this system, the parameters that influence the in vitro responsiveness of human lymphocytes to allogeneic lymphocytes have been investigated. PMID:4271568
Standardization of Clinical Assessment and Sample Collection Across All PERCH Study Sites
Prosperi, Christine; Baggett, Henry C.; Brooks, W. Abdullah; Deloria Knoll, Maria; Hammitt, Laura L.; Howie, Stephen R. C.; Kotloff, Karen L.; Levine, Orin S.; Madhi, Shabir A.; Murdoch, David R.; O’Brien, Katherine L.; Thea, Donald M.; Awori, Juliet O.; Bunthi, Charatdao; DeLuca, Andrea N.; Driscoll, Amanda J.; Ebruke, Bernard E.; Goswami, Doli; Hidgon, Melissa M.; Karron, Ruth A.; Kazungu, Sidi; Kourouma, Nana; Mackenzie, Grant; Moore, David P.; Mudau, Azwifari; Mwale, Magdalene; Nahar, Kamrun; Park, Daniel E.; Piralam, Barameht; Seidenberg, Phil; Sylla, Mamadou; Feikin, Daniel R.; Scott, J. Anthony G.; O’Brien, Katherine L.; Levine, Orin S.; Knoll, Maria Deloria; Feikin, Daniel R.; DeLuca, Andrea N.; Driscoll, Amanda J.; Fancourt, Nicholas; Fu, Wei; Hammitt, Laura L.; Higdon, Melissa M.; Kagucia, E. Wangeci; Karron, Ruth A.; Li, Mengying; Park, Daniel E.; Prosperi, Christine; Wu, Zhenke; Zeger, Scott L.; Watson, Nora L.; Crawley, Jane; Murdoch, David R.; Brooks, W. Abdullah; Endtz, Hubert P.; Zaman, Khalequ; Goswami, Doli; Hossain, Lokman; Jahan, Yasmin; Ashraf, Hasan; Howie, Stephen R. C.; Ebruke, Bernard E.; Antonio, Martin; McLellan, Jessica; Machuka, Eunice; Shamsul, Arifin; Zaman, Syed M.A.; Mackenzie, Grant; Scott, J. Anthony G.; Awori, Juliet O.; Morpeth, Susan C.; Kamau, Alice; Kazungu, Sidi; Kotloff, Karen L.; Tapia, Milagritos D.; Sow, Samba O.; Sylla, Mamadou; Tamboura, Boubou; Onwuchekwa, Uma; Kourouma, Nana; Toure, Aliou; Madhi, Shabir A.; Moore, David P.; Adrian, Peter V.; Baillie, Vicky L.; Kuwanda, Locadiah; Mudau, Azwifarwi; Groome, Michelle J.; Baggett, Henry C.; Thamthitiwat, Somsak; Maloney, Susan A.; Bunthi, Charatdao; Rhodes, Julia; Sawatwong, Pongpun; Akarasewi, Pasakorn; Thea, Donald M.; Mwananyanda, Lawrence; Chipeta, James; Seidenberg, Phil; Mwansa, James; wa Somwe, Somwe; Kwenda, Geoffrey
2017-01-01
Abstract Background. Variable adherence to standardized case definitions, clinical procedures, specimen collection techniques, and laboratory methods has complicated the interpretation of previous multicenter pneumonia etiology studies. To circumvent these problems, a program of clinical standardization was embedded in the Pneumonia Etiology Research for Child Health (PERCH) study. Methods. Between March 2011 and August 2013, standardized training on the PERCH case definition, clinical procedures, and collection of laboratory specimens was delivered to 331 clinical staff at 9 study sites in 7 countries (The Gambia, Kenya, Mali, South Africa, Zambia, Thailand, and Bangladesh), through 32 on-site courses and a training website. Staff competency was assessed throughout 24 months of enrollment with multiple-choice question (MCQ) examinations, a video quiz, and checklist evaluations of practical skills. Results. MCQ evaluation was confined to 158 clinical staff members who enrolled PERCH cases and controls, with scores obtained for >86% of eligible staff at each time-point. Median scores after baseline training were ≥80%, and improved by 10 percentage points with refresher training, with no significant intersite differences. Percentage agreement with the clinical trainer on the presence or absence of clinical signs on video clips was high (≥89%), with interobserver concordance being substantial to high (AC1 statistic, 0.62–0.82) for 5 of 6 signs assessed. Staff attained median scores of >90% in checklist evaluations of practical skills. Conclusions. Satisfactory clinical standardization was achieved within and across all PERCH sites, providing reassurance that any etiological or clinical differences observed across the study sites are true differences, and not attributable to differences in application of the clinical case definition, interpretation of clinical signs, or in techniques used for clinical measurements or specimen collection. PMID:28575355
Performance evaluation of the intra compression in the video coding standards
NASA Astrophysics Data System (ADS)
Abramowski, Andrzej
2015-09-01
The article presents a comparison of the Intra prediction algorithms in the current state-of-the-art video coding standards, including MJPEG 2000, VP8, VP9, H.264/AVC and H.265/HEVC. The effectiveness of techniques employed by each standard is evaluated in terms of compression efficiency and average encoding time. The compression efficiency is measured using BD-PSNR and BD-RATE metrics with H.265/HEVC results as an anchor. Tests are performed on a set of video sequences, composed of sequences gathered by Joint Collaborative Team on Video Coding during the development of the H.265/HEVC standard and 4K sequences provided by Ultra Video Group. According to results, H.265/HEVC provides significant bit-rate savings at the expense of computational complexity, while VP9 may be regarded as a compromise between the efficiency and required encoding time.
Stable aesthetic standards delusion: changing 'artistic quality' by elaboration.
Carbon, Claus-Christian; Hesslinger, Vera M
2014-01-01
The present study challenges the notion that judgments of artistic quality are based on stable aesthetic standards. We propose that such standards are a delusion and that judgments of artistic quality are the combined result of exposure, elaboration, and discourse. We ran two experiments using elaboration tasks based on the repeated evaluation technique in which different versions of the Mona Lisa had to be elaborated deeply. During the initial task either the version known from the Louvre or an alternative version owned by the Prado was elaborated; during the second task both versions were elaborated in a comparative fashion. After both tasks multiple blends of the two versions had to be evaluated concerning several aesthetic key variables. Judgments of artistic quality of the blends were significantly different depending on the initially elaborated version of the Mona Lisa, indicating experience-based aesthetic processing, which contradicts the notion of stable aesthetic standards.
Xiong, Zhenjie; Sun, Da-Wen; Pu, Hongbin; Gao, Wenhong; Dai, Qiong
2017-03-04
With improvement in people's living standards, many people nowadays pay more attention to quality and safety of meat. However, traditional methods for meat quality and safety detection and evaluation, such as manual inspection, mechanical methods, and chemical methods, are tedious, time-consuming, and destructive, which cannot meet the requirements of modern meat industry. Therefore, seeking out rapid, non-destructive, and accurate inspection techniques is important for the meat industry. In recent years, a number of novel and noninvasive imaging techniques, such as optical imaging, ultrasound imaging, tomographic imaging, thermal imaging, and odor imaging, have emerged and shown great potential in quality and safety assessment. In this paper, a detailed overview of advanced applications of these emerging imaging techniques for quality and safety assessment of different types of meat (pork, beef, lamb, chicken, and fish) is presented. In addition, advantages and disadvantages of each imaging technique are also summarized. Finally, future trends for these emerging imaging techniques are discussed, including integration of multiple imaging techniques, cost reduction, and developing powerful image-processing algorithms.
29 CFR 1908.9 - Monitoring and evaluation.
Code of Federal Regulations, 2010 CFR
2010-07-01
... ability to identify hazards in the workplaces which they have visited; their ability to determine employee... application of applicable Federal or State statutes, regulations or standards; their knowledge and application of appropriate hazard correction techniques and approaches; their knowledge and application of the...
Beneficial effects of semen purification with magnetic nanoparticles
USDA-ARS?s Scientific Manuscript database
Current techniques for sperm quality evaluation are mostly informative. They become useful when ejaculates of high index males not meeting quality standard are still discarded. Here we developed a molecular-based magnetic conjugates allowing selective elimination of damaged spermatozoa from semen ej...
Localized analysis of paint-coat drying using dynamic speckle interferometry
NASA Astrophysics Data System (ADS)
Sierra-Sosa, Daniel; Tebaldi, Myrian; Grumel, Eduardo; Rabal, Hector; Elmaghraby, Adel
2018-07-01
The paint-coating is part of several industrial processes, including the automotive industry, architectural coatings, machinery and appliances. These paint-coatings must comply with high quality standards, for this reason evaluation techniques from paint-coatings are in constant development. One important factor from the paint-coating process is the drying, as it has influence on the quality of final results. In this work we present an assessment technique based on the optical dynamic speckle interferometry, this technique allows for the temporal activity evaluation of the paint-coating drying process, providing localized information from drying. This localized information is relevant in order to address the drying homogeneity, optimal drying, and quality control. The technique relies in the definition of a new temporal history of the speckle patterns to obtain the local activity; this information is then clustered to provide a convenient indicative of different drying process stages. The experimental results presented were validated using the gravimetric drying curves
Single-incision Laparoscopic Surgery (SILS) in general surgery: a review of current practice.
Froghi, Farid; Sodergren, Mikael Hans; Darzi, Ara; Paraskeva, Paraskevas
2010-08-01
Single-incision laparoscopic surgery (SILS) aims to eliminate multiple port incisions. Although general operative principles of SILS are similar to conventional laparoscopic surgery, operative techniques are not standardized. This review aims to evaluate the current use of SILS published in the literature by examining the types of operations performed, techniques employed, and relevant complications and morbidity. This review considered a total of 94 studies reporting 1889 patients evaluating 17 different general surgical operations. There were 8 different access techniques reported using conventional laparoscopic instruments and specifically designed SILS ports. There is extensive heterogeneity associated with operating methods and in particular ways of overcoming problems with retraction and instrumentation. Published complications, morbidity, and hospital length of stay are comparable to conventional laparoscopy. Although SILS provides excellent cosmetic results and morbidity seems similar to conventional laparoscopy, larger randomized controlled trials are needed to assess the safety and efficacy of this novel technique.
Simulation and Modeling Capability for Standard Modular Hydropower Technology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stewart, Kevin M.; Smith, Brennan T.; Witt, Adam M.
Grounded in the stakeholder-validated framework established in Oak Ridge National Laboratory’s SMH Exemplary Design Envelope Specification, this report on Simulation and Modeling Capability for Standard Modular Hydropower (SMH) Technology provides insight into the concepts, use cases, needs, gaps, and challenges associated with modeling and simulating SMH technologies. The SMH concept envisions a network of generation, passage, and foundation modules that achieve environmentally compatible, cost-optimized hydropower using standardization and modularity. The development of standardized modeling approaches and simulation techniques for SMH (as described in this report) will pave the way for reliable, cost-effective methods for technology evaluation, optimization, and verification.
Standardized Photometric Calibrations for Panchromatic SSA Sensors
NASA Astrophysics Data System (ADS)
Castro, P.; Payne, T.; Battle, A.; Cole, Z.; Moody, J.; Gregory, S.; Dao, P.
2016-09-01
Panchromatic sensors used for Space Situational Awareness (SSA) have no standardized method for transforming the net flux detected by a CCD without a spectral filter into an exo-atmospheric magnitude in a standard magnitude system. Each SSA data provider appears to have their own method for computing the visual magnitude based on panchromatic brightness making cross-comparisons impossible. We provide a procedure in order to standardize the calibration of panchromatic sensors for the purposes of SSA. A technique based on theoretical modeling is presented that derives standard panchromatic magnitudes from the Johnson-Cousins photometric system defined by Arlo Landolt. We verify this technique using observations of Landolt standard stars and a Vega-like star to determine empirical panchromatic magnitudes and compare these to synthetically derived panchromatic magnitudes. We also investigate color terms caused by differences in the quantum efficiency (QE) between the Landolt standard system and panchromatic systems. We evaluate calibrated panchromatic satellite photometry by observing several GEO satellites and standard stars using three different sensors. We explore the effect of satellite color terms by comparing the satellite signatures. In order to remove other variables affecting the satellite photometry, two of the sensors are at the same site using different CCDs. The third sensor is geographically separate from the first two allowing for a definitive test of calibrated panchromatic satellite photometry.
Blind retrospective motion correction of MR images.
Loktyushin, Alexander; Nickisch, Hannes; Pohmann, Rolf; Schölkopf, Bernhard
2013-12-01
Subject motion can severely degrade MR images. A retrospective motion correction algorithm, Gradient-based motion correction, which significantly reduces ghosting and blurring artifacts due to subject motion was proposed. The technique uses the raw data of standard imaging sequences; no sequence modifications or additional equipment such as tracking devices are required. Rigid motion is assumed. The approach iteratively searches for the motion trajectory yielding the sharpest image as measured by the entropy of spatial gradients. The vast space of motion parameters is efficiently explored by gradient-based optimization with a convergence guarantee. The method has been evaluated on both synthetic and real data in two and three dimensions using standard imaging techniques. MR images are consistently improved over different kinds of motion trajectories. Using a graphics processing unit implementation, computation times are in the order of a few minutes for a full three-dimensional volume. The presented technique can be an alternative or a complement to prospective motion correction methods and is able to improve images with strong motion artifacts from standard imaging sequences without requiring additional data. Copyright © 2013 Wiley Periodicals, Inc., a Wiley company.
How Much Can Non-industry Standard Measurement Methodologies Benefit Methane Reduction Programs?
NASA Astrophysics Data System (ADS)
Risk, D. A.; O'Connell, L.; Atherton, E.
2017-12-01
In recent years, energy sector methane emissions have been recorded in large part by applying modern non-industry-standard techniques. Industry may lack the regulatory flexibility to use such techniques, or in some cases may not understand the possible associated economic advantage. As progressive jurisdictions move from estimation and towards routine measurement, the research community should provide guidance to help regulators and companies measure more effectively, and economically if possible. In this study, we outline a modelling experiment in which we explore the integration of non-industry-standard measurement techniques as part of a generalized compliance measurement program. The study was not intended to be exhaustive, or to recommend particular combinations, but instead to explore the inter-relationships between methodologies, development type, compliance practice. We first defined the role, applicable scale, detection limits, working distances, and approximate deployment cost of several measurement methodologies. We then considered a variety of development types differing mainly in footprint, density, and emissions "profile". Using a Monte Carlo approach, we evaluated the effect of these various factors on the cost and confidence of the compliance measurement program. We found that when added individually, some of the research techniques were indeed able to deliver an improvement in cost and/or confidence when used alongside industry-standard Optical Gas Imaging. When applied in combination, the ideal fraction of each measurement technique depended on development type, emission profile, and whether confidence or cost was more important. Results suggest that measurement cost and confidence could be improved if energy companies exploited a wider range of measurement techniques, and in a manner tailored to each development. In the short-term, combining clear scientific guidance with economic information could benefit immediate mitigation efforts over developing new super sensors.
NASA Astrophysics Data System (ADS)
Giovinazzo, G.; Ribas, N.; Cinca, J.; Rosell-Ferrer, J.
2010-04-01
Previous studies have shown that it is possible to evaluate heart graft rejection level using a bioimpedance technique by means of an intracavitary catheter. However, this technique does not present relevant advantages compared to the gold standard for the detection of a heart rejection, which is the biopsy of the endomyocardial tissue. We propose to use a less invasive technique that consists in the use of a transoesophageal catheter and two standard ECG electrodes on the thorax. The aim of this work is to evaluate different parameters affecting the impedance measurement, including: sensitivity to electrical conductivity and permittivity of different organs in the thorax, lung edema and pleural water. From these results, we deduce the best estimator for cardiac rejection detection, and we obtain the tools to identify possible cases of false positive of heart rejection due to other factors. To achieve these objectives we have created a thoracic model and we have simulated, with a FEM program, different situations at the frequencies of 13, 30, 100, 300 and 1000 kHz. Our simulation demonstrates that the phase, at 100 and 300 kHz, has the higher sensitivity to changes in the electrical parameters of the heart muscle.
Ippolito, Davide; Fior, Davide; Franzesi, Cammillo Talei; Riva, Luca; Casiraghi, Alessandra; Sironi, Sandro
2017-12-01
Effective radiation dose in coronary CT angiography (CTCA) for coronary artery bypass graft (CABG) evaluation is remarkably high because of long scan lengths. Prospective electrocardiographic gating with iterative reconstruction can reduce effective radiation dose. To evaluate the diagnostic performance of low-kV CT angiography protocol with prospective ecg-gating technique and iterative reconstruction (IR) algorithm in follow-up of CABG patients compared with standard retrospective protocol. Seventy-four non-obese patients with known coronary disease treated with artery bypass grafting were prospectively enrolled. All the patients underwent 256 MDCT (Brilliance iCT, Philips) CTCA using low-dose protocol (100 kV; 800 mAs; rotation time: 0.275 s) combined with prospective ECG-triggering acquisition and fourth-generation IR technique (iDose 4 ; Philips); all the lengths of the bypass graft were included in the evaluation. A control group of 42 similar patients was evaluated with a standard retrospective ECG-gated CTCA (100 kV; 800 mAs).On both CT examinations, ROIs were placed to calculate standard deviation of pixel values and intra-vessel density. Diagnostic quality was also evaluated using a 4-point quality scale. Despite the statistically significant reduction of radiation dose evaluated with DLP (study group mean DLP: 274 mGy cm; control group mean DLP: 1224 mGy cm; P value < 0.001). No statistical differences were found between PGA group and RGH group regarding intra-vessel density absolute values and SNR. Qualitative analysis, evaluated by two radiologists in "double blind", did not reveal any significant difference in diagnostic quality of the two groups. The development of high-speed MDCT scans combined with modern IR allows an accurate evaluation of CABG with prospective ECG-gating protocols in a single breath hold, obtaining a significant reduction in radiation dose.
Ma, Weina; Yang, Liu; Lv, Yanni; Fu, Jia; Zhang, Yanmin; He, Langchong
2017-06-23
The equilibrium dissociation constant (K D ) of drug-membrane receptor affinity is the basic parameter that reflects the strength of interaction. The cell membrane chromatography (CMC) method is an effective technique to study the characteristics of drug-membrane receptor affinity. In this study, the K D value of CMC relative standard method for the determination of drug-membrane receptor affinity was established to analyze the relative K D values of drugs binding to the membrane receptors (Epidermal growth factor receptor and angiotensin II receptor). The K D values obtained by the CMC relative standard method had a strong correlation with those obtained by the frontal analysis method. Additionally, the K D values obtained by CMC relative standard method correlated with pharmacological activity of the drug being evaluated. The CMC relative standard method is a convenient and effective method to evaluate drug-membrane receptor affinity. Copyright © 2017 Elsevier B.V. All rights reserved.
Piscaglia, Fabio; Marinelli, Sara; Bota, Simona; Serra, Carla; Venerandi, Laura; Leoni, Simona; Salvatore, Veronica
2014-03-01
This review illustrates the state of the art clinical applications and the future perspectives of ultrasound elastographic methods for the evaluation of chronic liver diseases, including the most widely used and validated technique, transient elastography, followed by shear wave elastography and strain imaging elastography. Liver ultrasound elastography allows the non-invasive evaluation of liver stiffness, providing information regarding the stage of fibrosis, comparable to liver biopsy which is still considered the gold standard; in this way, it can help physicians in managing patients, including the decision as to when to start antiviral treatment. The characterization of focal liver lesions and the prognostic role of the elastographic technique in the prediction of complications of cirrhosis are still under investigation. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Diagnostic imaging in bovine orthopedics.
Kofler, Johann; Geissbühler, Urs; Steiner, Adrian
2014-03-01
Although a radiographic unit is not standard equipment for bovine practitioners in hospital or field situations, ultrasound machines with 7.5-MHz linear transducers have been used in bovine reproduction for many years, and are eminently suitable for evaluation of orthopedic disorders. The goal of this article is to encourage veterinarians to use radiology and ultrasonography for the evaluation of bovine orthopedic disorders. These diagnostic imaging techniques improve the likelihood of a definitive diagnosis in every bovine patient but especially in highly valuable cattle, whose owners demand increasingly more diagnostic and surgical interventions that require high-level specialized techniques. Copyright © 2014 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Wigley, D. A.
1982-01-01
A proposed configuration for a stepped specimen to be used in the system evaluation of mechanisms that can introduce warpage or dimensional changes in metallic alloys used for cryogenic wind tunnel models is described. Considerations for selecting a standard specimen are presented along with results obtained from an investigation carried out for VASCOMAX 200 maraging steel. Details of the machining and measurement techniques utilized in the investigation are presented. Initial results from the sample of VASCOMAX 200 show that the configuration and measuring techniques are capable of giving quantitative results.
Rapid adhesive bonding of advanced composites and titanium
NASA Technical Reports Server (NTRS)
Stein, B. A.; Tyeryart, J. R.; Hodgest, W. T.
1985-01-01
Rapid adhesive bonding (RAB) concepts utilize a toroid induction technique to heat the adhesive bond line directly. This technique was used to bond titanium overlap shear specimens with 3 advanced thermoplastic adhesives and APC-2 (graphite/PEEK) composites with PEEK film. Bond strengths equivalent to standard heated-platen press bonds were produced with large reductions in process time. RAB produced very strong bonds in APC-2 adherend specimens; the APC-2 adherends were highly resistant to delamination. Thermal cycling did not significantly affect the shear strengths of RAB titanium bonds with polyimide adhesives. A simple ultrasonic non-destructive evaluation process was found promising for evaluating bond quality.
Extending the Distributed Lag Model framework to handle chemical mixtures.
Bello, Ghalib A; Arora, Manish; Austin, Christine; Horton, Megan K; Wright, Robert O; Gennings, Chris
2017-07-01
Distributed Lag Models (DLMs) are used in environmental health studies to analyze the time-delayed effect of an exposure on an outcome of interest. Given the increasing need for analytical tools for evaluation of the effects of exposure to multi-pollutant mixtures, this study attempts to extend the classical DLM framework to accommodate and evaluate multiple longitudinally observed exposures. We introduce 2 techniques for quantifying the time-varying mixture effect of multiple exposures on an outcome of interest. Lagged WQS, the first technique, is based on Weighted Quantile Sum (WQS) regression, a penalized regression method that estimates mixture effects using a weighted index. We also introduce Tree-based DLMs, a nonparametric alternative for assessment of lagged mixture effects. This technique is based on the Random Forest (RF) algorithm, a nonparametric, tree-based estimation technique that has shown excellent performance in a wide variety of domains. In a simulation study, we tested the feasibility of these techniques and evaluated their performance in comparison to standard methodology. Both methods exhibited relatively robust performance, accurately capturing pre-defined non-linear functional relationships in different simulation settings. Further, we applied these techniques to data on perinatal exposure to environmental metal toxicants, with the goal of evaluating the effects of exposure on neurodevelopment. Our methods identified critical neurodevelopmental windows showing significant sensitivity to metal mixtures. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Ctvrtnickova, T.; Mateo, M. P.; Yañez, A.; Nicolas, G.
2011-04-01
Presented work brings results of Laser-Induced Breakdown Spectroscopy (LIBS) and Thermo-Mechanical Analysis (TMA) of coals and coal blends used in coal fired power plants all over Spain. Several coal specimens, its blends and corresponding laboratory ash were analyzed by mentioned techniques and results were compared to standard laboratory methods. The indices of slagging, which predict the tendency of coal ash deposition on the boiler walls, were determined by means of standard chemical analysis, LIBS and TMA. The optimal coal suitable to be blended with the problematic national lignite coal was suggested in order to diminish the slagging problems. Used techniques were evaluated based on the precision, acquisition time, extension and quality of information they could provide. Finally, the applicability of LIBS and TMA to the successful calculation of slagging indices is discussed and their substitution of time-consuming and instrumentally difficult standard methods is considered.
Hand sensibility measures used by therapists.
Mielke, K; Novak, C B; Mackinnon, S E; Feely, C A
1996-03-01
Sensory evaluations are frequently used to assess patients with functional loss resulting from nerve injury. The results of these tests are routinely utilized by hand surgeons as an indication for conservative management or surgical intervention in the evaluation of surgical outcome and in the determination of disability ratings. Reports in the literature regarding specific tests for sensibility show variation in their application. The purpose of this study was to evaluate which tests are used to evaluate hand sensibility and the techniques of application currently used by hand therapists. Two hundred members of the American Society of Hand Therapists were randomly selected and a survey was sent to these members. The results of this study identify the need to develop standardized protocols for sensory evaluations and the need for therapists to follow the standardized methods for administration of moving and static two-point discrimination, and Semmes-Weinstein monofilaments, if comparisons of results between centers are to be meaningful.
NASA Astrophysics Data System (ADS)
Wu, Fan; Cao, Pin; Yang, Yongying; Li, Chen; Chai, Huiting; Zhang, Yihui; Xiong, Haoliang; Xu, Wenlin; Yan, Kai; Zhou, Lin; Liu, Dong; Bai, Jian; Shen, Yibing
2016-11-01
The inspection of surface defects is one of significant sections of optical surface quality evaluation. Based on microscopic scattering dark-field imaging, sub-aperture scanning and stitching, the Surface Defects Evaluating System (SDES) can acquire full-aperture image of defects on optical elements surface and then extract geometric size and position information of defects with image processing such as feature recognization. However, optical distortion existing in the SDES badly affects the inspection precision of surface defects. In this paper, a distortion correction algorithm based on standard lattice pattern is proposed. Feature extraction, polynomial fitting and bilinear interpolation techniques in combination with adjacent sub-aperture stitching are employed to correct the optical distortion of the SDES automatically in high accuracy. Subsequently, in order to digitally evaluate surface defects with American standard by using American military standards MIL-PRF-13830B to judge the surface defects information obtained from the SDES, an American standard-based digital evaluation algorithm is proposed, which mainly includes a judgment method of surface defects concentration. The judgment method establishes weight region for each defect and adopts the method of overlap of weight region to calculate defects concentration. This algorithm takes full advantage of convenience of matrix operations and has merits of low complexity and fast in running, which makes itself suitable very well for highefficiency inspection of surface defects. Finally, various experiments are conducted and the correctness of these algorithms are verified. At present, these algorithms have been used in SDES.
Allen, Robert C; John, Mallory G; Rutan, Sarah C; Filgueira, Marcelo R; Carr, Peter W
2012-09-07
A singular value decomposition-based background correction (SVD-BC) technique is proposed for the reduction of background contributions in online comprehensive two-dimensional liquid chromatography (LC×LC) data. The SVD-BC technique was compared to simply subtracting a blank chromatogram from a sample chromatogram and to a previously reported background correction technique for one dimensional chromatography, which uses an asymmetric weighted least squares (AWLS) approach. AWLS was the only background correction technique to completely remove the background artifacts from the samples as evaluated by visual inspection. However, the SVD-BC technique greatly reduced or eliminated the background artifacts as well and preserved the peak intensity better than AWLS. The loss in peak intensity by AWLS resulted in lower peak counts at the detection thresholds established using standards samples. However, the SVD-BC technique was found to introduce noise which led to detection of false peaks at the lower detection thresholds. As a result, the AWLS technique gave more precise peak counts than the SVD-BC technique, particularly at the lower detection thresholds. While the AWLS technique resulted in more consistent percent residual standard deviation values, a statistical improvement in peak quantification after background correction was not found regardless of the background correction technique used. Copyright © 2012 Elsevier B.V. All rights reserved.
Automated 3D ultrasound measurement of the angle of progression in labor.
Montaguti, Elisa; Rizzo, Nicola; Pilu, Gianluigi; Youssef, Aly
2018-01-01
To assess the feasibility and reliability of an automated technique for the assessment of the angle of progression (AoP) in labor by using three-dimensional (3D) ultrasound. AoP was assessed by using 3D transperineal ultrasound by two operators in 52 women in active labor to evaluate intra- and interobserver reproducibility. Furthermore, intermethod agreement between automated and manual techniques on 3D images, and between automated technique on 3D vs 2D images were evaluated. Automated measurements were feasible in all cases. Automated measurements were considered acceptable in 141 (90.4%) out of the 156 on the first assessments and in all 156 after repeating measurements for unacceptable evaluations. The automated technique on 3D images demonstrated good intra- and interobserver reproducibility. The 3D-automated technique showed a very good agreement with the 3D manual technique. Notably, AoP calculated with the 3D automated technique were significantly wider in comparison with those measured manually on 3D images (133 ± 17° vs 118 ± 21°, p = 0.013). The assessment of the angle of progression through 3D ultrasound is highly reproducible. However, automated software leads to a systematic overestimation of AoP in comparison with the standard manual technique thus hindering its use in clinical practice in its present form.
2014-01-01
Background The purpose of this study was to compare two impression techniques from the perspective of patient preferences and treatment comfort. Methods Twenty-four (12 male, 12 female) subjects who had no previous experience with either conventional or digital impression participated in this study. Conventional impressions of maxillary and mandibular dental arches were taken with a polyether impression material (Impregum, 3 M ESPE), and bite registrations were made with polysiloxane bite registration material (Futar D, Kettenbach). Two weeks later, digital impressions and bite scans were performed using an intra-oral scanner (CEREC Omnicam, Sirona). Immediately after the impressions were made, the subjects’ attitudes, preferences and perceptions towards impression techniques were evaluated using a standardized questionnaire. The perceived source of stress was evaluated using the State-Trait Anxiety Scale. Processing steps of the impression techniques (tray selection, working time etc.) were recorded in seconds. Statistical analyses were performed with the Wilcoxon Rank test, and p < 0.05 was considered significant. Results There were significant differences among the groups (p < 0.05) in terms of total working time and processing steps. Patients stated that digital impressions were more comfortable than conventional techniques. Conclusions Digital impressions resulted in a more time-efficient technique than conventional impressions. Patients preferred the digital impression technique rather than conventional techniques. PMID:24479892
Gold-standard for computer-assisted morphological sperm analysis.
Chang, Violeta; Garcia, Alejandra; Hitschfeld, Nancy; Härtel, Steffen
2017-04-01
Published algorithms for classification of human sperm heads are based on relatively small image databases that are not open to the public, and thus no direct comparison is available for competing methods. We describe a gold-standard for morphological sperm analysis (SCIAN-MorphoSpermGS), a dataset of sperm head images with expert-classification labels in one of the following classes: normal, tapered, pyriform, small or amorphous. This gold-standard is for evaluating and comparing known techniques and future improvements to present approaches for classification of human sperm heads for semen analysis. Although this paper does not provide a computational tool for morphological sperm analysis, we present a set of experiments for comparing sperm head description and classification common techniques. This classification base-line is aimed to be used as a reference for future improvements to present approaches for human sperm head classification. The gold-standard provides a label for each sperm head, which is achieved by majority voting among experts. The classification base-line compares four supervised learning methods (1- Nearest Neighbor, naive Bayes, decision trees and Support Vector Machine (SVM)) and three shape-based descriptors (Hu moments, Zernike moments and Fourier descriptors), reporting the accuracy and the true positive rate for each experiment. We used Fleiss' Kappa Coefficient to evaluate the inter-expert agreement and Fisher's exact test for inter-expert variability and statistical significant differences between descriptors and learning techniques. Our results confirm the high degree of inter-expert variability in the morphological sperm analysis. Regarding the classification base line, we show that none of the standard descriptors or classification approaches is best suitable for tackling the problem of sperm head classification. We discovered that the correct classification rate was highly variable when trying to discriminate among non-normal sperm heads. By using the Fourier descriptor and SVM, we achieved the best mean correct classification: only 49%. We conclude that the SCIAN-MorphoSpermGS will provide a standard tool for evaluation of characterization and classification approaches for human sperm heads. Indeed, there is a clear need for a specific shape-based descriptor for human sperm heads and a specific classification approach to tackle the problem of high variability within subcategories of abnormal sperm cells. Copyright © 2017 Elsevier Ltd. All rights reserved.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 1 2010-10-01 2010-10-01 false Reproduction. 9.7 Section 9.7 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL PROVISIONS STANDARDS OF CARE FOR... through laboratory testing for semen. Seminal collection techniques must be carefully evaluated to avoid...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 1 2011-10-01 2011-10-01 false Reproduction. 9.7 Section 9.7 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL PROVISIONS STANDARDS OF CARE FOR... through laboratory testing for semen. Seminal collection techniques must be carefully evaluated to avoid...
Screening and Assessing Adolescent Substance Use Disorders in Clinical Populations
ERIC Educational Resources Information Center
Winters, Ken C.; Kaminer, Yifrah
2008-01-01
The different established screening methodologies and comprehensive assessment techniques used in evaluating adolescents suspected of or known to have substance abuse disorders are discussed. Recommendations and suggestions for establishing standards of training and professional efficiency are also highlighted to treat adolescents with substance…
EVALUATION OF BIOSOLID SAMPLE PROCESSING TECHNIQUES TO MAXIMIZE RECOVERY OF BACTERIA
Current federal regulations (40 CFR 503) require enumeration of fecal coliform or Salmoella prior to land application of Class A biosolids. This regulation specifies use of enumeration methods included in "Standard Methods for the Examination of Water and Wastewater 18th Edition,...
Manning, Todd G; Papa, Nathan; Perera, Marlon; McGrath, Shannon; Christidis, Daniel; Khan, Munad; O'Beirne, Richard; Campbell, Nicholas; Bolton, Damien; Lawrentschuk, Nathan
2018-03-01
Laparoscopic lens fogging (LLF) hampers vision and impedes operative efficiency. Attempts to reduce LLF have led to the development of various anti-fogging fluids and warming devices. Limited literature exists directly comparing these techniques. We constructed a model peritoneum to simulate LLF and to compare the efficacy of various anti-fogging techniques. Intraperitoneal space was simulated using a suction bag suspended within an 8 L container of water. LLF was induced by varying the temperature and humidity within the model peritoneum. Various anti-fogging techniques were assessed including scope warmers, FRED TM , Resoclear TM , chlorhexidine, betadine and immersion in heated saline. These products were trialled with and without the use of a disposable scope warmer. Vision scores were evaluated by the same investigator for all tests and rated according to a predetermined scale. Fogging was assessed for each product or technique 30 times and a mean vision rating was recorded. All products tested imparted some benefit, but FRED TM performed better than all other techniques. Betadine and Resoclear TM performed no better than the use of a scope warmer alone. Immersion in saline prior to insertion resulted in decreased vision ratings. The robotic scope did not result in LLF within the model. In standard laparoscopes, the most superior preventative measure was FRED TM utilised on a pre-warmed scope. Despite improvements in LLF with other products FRED TM was better than all other techniques. The robotic laparoscope performed superiorly regarding LLF compared to standard laparoscope.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walker, Iain S.; Wray, Craig P.; Guillot, Cyril
2003-08-01
In this report, we discuss the accuracy of flow hoods for residential applications, based on laboratory tests and field studies. The results indicate that commercially available hoods are often inadequate to measure flows in residential systems, and that there can be a wide range of performance between different flow hoods. The errors are due to poor calibrations, sensitivity of existing hoods to grille flow non-uniformities, and flow changes from added flow resistance. We also evaluated several simple techniques for measuring register airflows that could be adopted by the HVAC industry and homeowners as simple diagnostics that are often as accuratemore » as commercially available devices. Our test results also show that current calibration procedures for flow hoods do not account for field application problems. As a result, organizations such as ASHRAE or ASTM need to develop a new standard for flow hood calibration, along with a new measurement standard to address field use of flow hoods.« less
Specificity of coliphages in evaluating marker efficacy: a new insight for water quality indicators.
Mookerjee, Subham; Batabyal, Prasenjit; Halder, Madhumanti; Palit, Anup
2014-11-01
Conventional procedures for qualitative assessment of coliphage are time consuming multiple step approach for achieving results. A modified and rapid technique has been introduced for determination of coliphage contamination among potable water sources during water borne outbreaks. During December 2013, 40 water samples from different potable water sources, were received for water quality analyses, from a jaundice affected Municipality of West Bengal, India. Altogether, 30% water samples were contaminated with coliform (1-20 cfu/ml) and 5% with E. coli (2-5 cfu/ml). Among post-outbreak samples, preponderance of coliform has decreased (1-4 cfu/ml) with total absence of E. coli. While standard technique has detected 55% outbreak samples with coliphage contamination, modified technique revealed that 80%, double than that of bacteriological identification rate, were contaminated with coliphages (4-20 pfu/10 ml). However, post-outbreak samples were detected with 1-5 pfu/10 ml coliphages among 20% samples. Coliphage detection rate through modified technique was nearly double (50%) than that of standard technique (27.5%). In few samples (with coliform load of 10-100 cfu/ml), while modified technique could detect coliphages among six samples (10-20 pfu/10 ml), standard protocol failed to detect coliphage in any of them. An easy, rapid and accurate modified technique has thereby been implemented for coliphage assessment from water samples. Coliform free water does not always signify pathogen free potable water and it is demonstrated that coliphage is a more reliable 'biomarker' to ascertain contamination level in potable water. Copyright © 2014 Elsevier B.V. All rights reserved.
Pansharpening on the Narrow Vnir and SWIR Spectral Bands of SENTINEL-2
NASA Astrophysics Data System (ADS)
Vaiopoulos, A. D.; Karantzalos, K.
2016-06-01
In this paper results from the evaluation of several state-of-the-art pansharpening techniques are presented for the VNIR and SWIR bands of Sentinel-2. A procedure for the pansharpening is also proposed which aims at respecting the closest spectral similarities between the higher and lower resolution bands. The evaluation included 21 different fusion algorithms and three evaluation frameworks based both on standard quantitative image similarity indexes and qualitative evaluation from remote sensing experts. The overall analysis of the evaluation results indicated that remote sensing experts disagreed with the outcomes and method ranking from the quantitative assessment. The employed image quality similarity indexes and quantitative evaluation framework based on both high and reduced resolution data from the literature didn't manage to highlight/evaluate mainly the spatial information that was injected to the lower resolution images. Regarding the SWIR bands none of the methods managed to deliver significantly better results than a standard bicubic interpolation on the original low resolution bands.
Lassau, Nathalie; Chapotot, Louis; Benatsou, Baya; Vilgrain, Valérie; Kind, Michèle; Lacroix, Joëlle; Cuinet, Marie; Taieb, Sophie; Aziza, Richard; Sarran, Antony; Labbe, Catherine; Gallix, Benoît; Lucidarme, Olivier; Ptak, Yvette; Rocher, Laurence; Caquot, Louis Michel; Chagnon, Sophie; Marion, Denis; Luciani, Alain; Uzan-Augui, Joëlle; Koscielny, Serge
2012-12-01
The objectives of this study are to describe the standardization and dissemination of dynamic contrast-enhanced ultrasound (DCE-US) for the evaluation of antiangiogenic treatments in solid tumors across 19 oncology centers in France and to define a quality score to account for the variability of the evaluation criteria used to collect DCE-US data. This prospective Soutien aux Techniques Innovantes Coûteuses (Support for Innovative and Expensive Techniques) DCE-US study included patients with metastatic breast cancer, melanoma, colon cancer, gastrointestinal stromal tumors, renal cell carcinoma and patients with primary hepatocellular carcinoma tumors treated with antiangiogenic therapy. The DCE-US method was made available across 19 oncology centers in France. Overall, 2339 DCE-US examinations were performed by 65 radiologists in 539 patients.One target site per patient was studied. Standardized DCE-US examinations were performed before treatment (day 0) and at days 7, 15, 30, and 60. Dynamic contrast-enhanced ultrasound data were transferred from the different sites to the main study center at the Institut Gustave-Roussy for analysis. Quantitative analyses were performed with a mathematical model to determine 7 DCE-US functional parameters using raw linear data. Radiologists had to evaluate 6 criteria that were potentially linked to the precision of the evaluation of these parameters: lesion size, target motion, loss of target, clear borders, total acquisition of wash-in, and vascular recognition imaging window adapted to the lesion size.Eighteen DCE-US examinations were randomly selected from the Soutien aux Techniques Innovantes Coûteuses (Support for Innovative and Expensive Techniques) database. Each examination was quantified twice by 8 engineers/radiologists trained to evaluate the perfusion parameters. The intraobserver variability was estimated on the basis of differences between examinations performed by the same radiologist. The mean coefficient of variability associated with each quality criterion was estimated. The final quality score, ranging from 0 to 5, was defined according to the value of coefficient of variability for each criterion. A total of 2062 examinations were stored with raw linear data. Five criteria were found to have a major impact on quality: lesion size, motion, loss of target, borders, and total acquisition of wash-in. Only 3% of the examinations were of poor quality (quality of 0); quality was correlated with the radiologists' experience, such that it was significantly higher for radiologists who had performed more than 60 DCE-US examinations (P < 0.0001). The DCE-US methodology has been successfully provided to several centers across France together with strict rules for quality assessment. Only 3% of examinations carried out at these centers were considered not interpretable.
Sharma, Malay; Rai, Praveer; Mehta, Varun; Rameshbabu, C. S.
2015-01-01
Endoscopic ultrasonography (EUS) is a useful modality for imaging of the blood vessels of the mediastinum and abdomen. The aorta acts as an important home base during EUS imaging. The aorta and its branches are accessible by standard angiographic methods, but endosonography also provides a unique opportunity to evaluate the aorta and its branches. This article describes the techniques of imaging of different part of the aorta by EUS. PMID:26020043
Tantra, Ratna; Knight, Alex
2011-09-01
The use of imaging tools to probe nanoparticle-cell interactions will be crucial to elucidating the mechanisms of nanoparticle-induced toxicity. Of particular interest are mechanisms associated with cell penetration, translocation and subsequent accumulation inside the cell, or in cellular compartments. The objective of the present paper is to review imaging techniques that have been previously used in order to assess such interactions, and new techniques with the potential to be useful in this area. In order to identify the most suitable techniques, they were evaluated and matched against a list of evaluation criteria. We conclude that limitations exist with all of the techniques and the ultimate choice will thus depend on the needs of end users, and their particular application. The state-of-the-art techniques appear to have the least limitations, despite the fact that they are not so well established and still far from being routine. For example, super-resolution microscopy techniques appear to have many advantages for understanding the details of the interactions between nanoparticles and cells. Future research should concentrate on further developing or improving such novel techniques, to include the development of standardized methods and appropriate reference materials.
Jaspers, Mariëlle E H; van Haasterecht, Ludo; van Zuijlen, Paul P M; Mokkink, Lidwine B
2018-06-22
Reliable and valid assessment of burn wound depth or healing potential is essential to treatment decision-making, to provide a prognosis, and to compare studies evaluating different treatment modalities. The aim of this review was to critically appraise, compare and summarize the quality of relevant measurement properties of techniques that aim to assess burn wound depth or healing potential. A systematic literature search was performed using PubMed, EMBASE and Cochrane Library. Two reviewers independently evaluated the methodological quality of included articles using an adapted version of the Consensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist. A synthesis of evidence was performed to rate the measurement properties for each technique and to draw an overall conclusion on quality of the techniques. Thirty-six articles were included, evaluating various techniques, classified as (1) laser Doppler techniques; (2) thermography or thermal imaging; (3) other measurement techniques. Strong evidence was found for adequate construct validity of laser Doppler imaging (LDI). Moderate evidence was found for adequate construct validity of thermography, videomicroscopy, and spatial frequency domain imaging (SFDI). Only two studies reported on the measurement property reliability. Furthermore, considerable variation was observed among comparator instruments. Considering the evidence available, it appears that LDI is currently the most favorable technique; thereby assessing burn wound healing potential. Additional research is needed into thermography, videomicroscopy, and SFDI to evaluate their full potential. Future studies should focus on reliability and measurement error, and provide a precise description of which construct is aimed to measure. Copyright © 2018 Elsevier Ltd and ISBI. All rights reserved.
Internal Medicine House Officers' Performance as Assessed by Experts and Standardized Patients.
ERIC Educational Resources Information Center
Calhoun, Judith G.; And Others
1987-01-01
Three chronically ill patients were trained to evaluate the performance of 31 second-year internal medicine house officers based upon: a checklist for the medical data elicited during the medical interview; the process of the interview; and the physical examination technique. (Author/MLW)
Hypnotherapy for labor and birth.
Beebe, Kathleen R
2014-01-01
Hypnotherapy is an integrative mind-body technique with therapeutic potential in various health care applications, including labor and birth. Evaluating the efficacy of this modality in controlled studies can be difficult, because of methodologic challenges, such as obtaining adequate sample sizes and standardizing experimental conditions. Women using hypnosis techniques for childbirth in hospital settings may face barriers related to caregiver resistance or institutional policies. The potential anxiolytic and analgesic effects of clinical hypnosis for childbirth merit further study. Nurses caring for women during labor and birth can increase their knowledge and skills with strategies for supporting hypnotherapeutic techniques. © 2014 AWHONN.
Narrow band imaging combined with water immersion technique in the diagnosis of celiac disease.
Valitutti, Francesco; Oliva, Salvatore; Iorfida, Donatella; Aloi, Marina; Gatti, Silvia; Trovato, Chiara Maria; Montuori, Monica; Tiberti, Antonio; Cucchiara, Salvatore; Di Nardo, Giovanni
2014-12-01
The "multiple-biopsy" approach both in duodenum and bulb is the best strategy to confirm the diagnosis of celiac disease; however, this increases the invasiveness of the procedure itself and is time-consuming. To evaluate the diagnostic yield of a single biopsy guided by narrow-band imaging combined with water immersion technique in paediatric patients. Prospective assessment of the diagnostic accuracy of narrow-band imaging/water immersion technique-driven biopsy approach versus standard protocol in suspected celiac disease. The experimental approach correctly diagnosed 35/40 children with celiac disease, with an overall diagnostic sensitivity of 87.5% (95% CI: 77.3-97.7). An altered pattern of narrow-band imaging/water immersion technique endoscopic visualization was significantly associated with villous atrophy at guided biopsy (Spearman Rho 0.637, p<0.001). Concordance of narrow-band imaging/water immersion technique endoscopic assessments was high between two operators (K: 0.884). The experimental protocol was highly timesaving compared to the standard protocol. An altered narrow-band imaging/water immersion technique pattern coupled with high anti-transglutaminase antibodies could allow a single guided biopsy to diagnose celiac disease. When no altered mucosal pattern is visible even by narrow-band imaging/water immersion technique, multiple bulbar and duodenal biopsies should be obtained. Copyright © 2014. Published by Elsevier Ltd.
Morelli, Girolamo; Pagni, Riccardo; Mariani, Chiara; Minervini, Riccardo; Morelli, Andrea; Gori, Francesco; Ferdeghini, Ezio Maria; Paterni, Marco; Mauro, Eva; Guidi, Elisa; Armillotta, Nicola; Canale, Domenico; Vitti, Paolo; Caramella, Davide; Minervini, Andrea
2011-06-01
We evaluated the ability of the phosphodiesterase-5 inhibitor vardenafil to increase prostate microcirculation during power Doppler ultrasound. We also evaluated the results of contrast and vardenafil enhanced targeted biopsies compared to those of standard 12-core random biopsies to detect cancer. Between May 2008 and January 2010, 150 consecutive patients with prostate specific antigen more than 4 ng/ml at first diagnosis with negative digital rectal examination and transrectal ultrasound, and no clinical history of prostatitis underwent contrast enhanced power Doppler ultrasound (bolus injection of 2.4 ml SonoVue® contrast agent), followed by vardenafil enhanced power Doppler ultrasound (1 hour after oral administration of vardenafil 20 mg). All patients underwent standard 12-core transrectal ultrasound guided random prostate biopsy plus 1 further sampling from each suspected hypervascular lesion detected by contrast and vardenafil enhanced power Doppler ultrasound. Prostate cancer was detected in 44 patients (29.3%). Contrast and vardenafil enhanced power Doppler ultrasound detected suspicious, contrast enhanced and vardenafil enhanced areas in 112 (74.6%) and 110 patients (73.3%), and was diagnostic for cancer in 32 (28.5%) and 42 (38%), respectively. Analysis of standard technique, and contrast and vardenafil enhanced power Doppler ultrasound findings by biopsy core showed significantly higher detection using vardenafil vs contrast enhanced power Doppler ultrasound and standard technique (41.2% vs 22.7% and 8.1%, p <0.005 and <0.001, respectively). The detection rate of standard plus contrast or vardenafil enhanced power Doppler ultrasound was 10% and 11.7% (p not significant). Vardenafil enhanced power Doppler ultrasound enables excellent visualization of the microvasculature associated with cancer and can improve the detection rate compared to contrast enhanced power Doppler ultrasound and the random technique. Copyright © 2011 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Selmi, Giuliana da Fontoura Rodrigues; Trapé, Angelo Zanaga
2014-05-01
Quantification of dermal exposure to pesticides in rural workers, used in risk assessment, can be performed with different techniques such as patches or whole body evaluation. However, the wide variety of methods can jeopardize the process by producing disparate results, depending on the principles in sample collection. A critical review was thus performed on the main techniques for quantifying dermal exposure, calling attention to this issue and the need to establish a single methodology for quantification of dermal exposure in rural workers. Such harmonization of different techniques should help achieve safer and healthier working conditions. Techniques that can provide reliable exposure data are an essential first step towards avoiding harm to workers' health.
DOE Office of Scientific and Technical Information (OSTI.GOV)
MacFarlane, Michael; Battista, Jerry; Chen, Jeff
Purpose: To develop a radiotherapy dose tracking and plan evaluation technique using cone-beam computed tomography (CBCT) images. Methods: We developed a patient-specific method of calibrating CBCT image sets for dose calculation. The planning CT was first registered with the CBCT using deformable image registration (DIR). A scatter plot was generated between the CT numbers of the planning CT and CBCT for each slice. The CBCT calibration curve was obtained by least-square fitting of the data, and applied to each CBCT slice. The calibrated CBCT was then merged with original planning CT to extend the small field of view of CBCT.more » Finally, the treatment plan was copied to the merged CT for dose tracking and plan evaluation. The proposed patient-specific calibration method was also compared to two methods proposed in literature. To evaluate the accuracy of each technique, 15 head-and-neck patients requiring plan adaptation were arbitrarily selected from our institution. The original plan was calculated on each method’s data set, including a second planning CT acquired within 48 hours of the CBCT (serving as gold standard). Clinically relevant dose metrics and 3D gamma analysis of dose distributions were compared between the different techniques. Results: Compared to the gold standard of using planning CTs, the patient-specific CBCT calibration method was shown to provide promising results with gamma pass rates above 95% and average dose metric agreement within 2.5%. Conclusions: The patient-specific CBCT calibration method could potentially be used for on-line dose tracking and plan evaluation, without requiring a re-planning CT session.« less
Space Shuttle Program: STS-1 Medical Report
NASA Technical Reports Server (NTRS)
1981-01-01
The necessity for developing medical standards addressing individual classes of Shuttle crew positions is discussed. For the U.S. manned program the conclusion of the Apollo era heralded the end of water recovery operations and the introduction of land-based medical operations. This procedural change marked a significant departure from the accepted postflight medical recovery and evaluation techniques. All phases of the missions required careful re-evaluation, identification of potential impact on preexisting medical operational techniques, and development of new methodologies which were carefully evaluated and tested under simulated conditions. Significant coordination was required between the different teams involved in medical operations. Additional dimensions were added to the concepts of medical operations, by the introduction of different toxic substances utilized by the Space Transportation Systems especially during ground operations.
Minimal Residual Disease in Acute Myeloid Leukemia: Still a Work in Progress?
Mosna, Federico; Capelli, Debora; Gottardi, Michele
2017-01-01
Minimal residual disease evaluation refers to a series of molecular and immunophenotypical techniques aimed at detecting submicroscopic disease after therapy. As such, its application in acute myeloid leukemia has greatly increased our ability to quantify treatment response, and to determine the chemosensitivity of the disease, as the final product of the drug schedule, dose intensity, biodistribution, and the pharmakogenetic profile of the patient. There is now consistent evidence for the prognostic power of minimal residual disease evaluation in acute myeloid leukemia, which is complementary to the baseline prognostic assessment of the disease. The focus for its use is therefore shifting to individualize treatment based on a deeper evaluation of chemosensitivity and residual tumor burden. In this review, we will summarize the results of the major clinical studies evaluating minimal residual disease in acute myeloid leukemia in adults in recent years and address the technical and practical issues still hampering the spread of these techniques outside controlled clinical trials. We will also briefly speculate on future developments and offer our point of view, and a word of caution, on the present use of minimal residual disease measurements in “real-life” practice. Still, as final standardization and diffusion of the methods are sorted out, we believe that minimal residual disease will soon become the new standard for evaluating response in the treatment of acute myeloid leukemia. PMID:28587190
Thomas-Gibson, Siwan; Bugajski, Marek; Bretthauer, Michael; Rees, Colin J; Dekker, Evelien; Hoff, Geir; Jover, Rodrigo; Suchanek, Stepan; Ferlitsch, Monika; Anderson, John; Roesch, Thomas; Hultcranz, Rolf; Racz, Istvan; Kuipers, Ernst J; Garborg, Kjetil; East, James E; Rupinski, Maciej; Seip, Birgitte; Bennett, Cathy; Senore, Carlo; Minozzi, Silvia; Bisschops, Raf; Domagk, Dirk; Valori, Roland; Spada, Cristiano; Hassan, Cesare; Dinis-Ribeiro, Mario; Rutter, Matthew D
2017-01-01
The European Society of Gastrointestinal Endoscopy and United European Gastroenterology present a short list of key performance measures for lower gastrointestinal endoscopy. We recommend that endoscopy services across Europe adopt the following seven key performance measures for lower gastrointestinal endoscopy for measurement and evaluation in daily practice at a center and endoscopist level: 1 rate of adequate bowel preparation (minimum standard 90%); 2 cecal intubation rate (minimum standard 90%); 3 adenoma detection rate (minimum standard 25%); 4 appropriate polypectomy technique (minimum standard 80%); 5 complication rate (minimum standard not set); 6 patient experience (minimum standard not set); 7 appropriate post-polypectomy surveillance recommendations (minimum standard not set). Other identified performance measures have been listed as less relevant based on an assessment of their importance, scientific acceptability, feasibility, usability, and comparison to competing measures. PMID:28507745
IMIRSEL: a secure music retrieval testing environment
NASA Astrophysics Data System (ADS)
Downie, John S.
2004-10-01
The Music Information Retrieval (MIR) and Music Digital Library (MDL) research communities have long noted the need for formal evaluation mechanisms. Issues concerning the unavailability of freely-available music materials have greatly hindered the creation of standardized test collections with which these communities could scientifically assess the strengths and weaknesses of their various music retrieval techniques. The International Music Information Retrieval Systems Evaluation Laboratory (IMIRSEL) is being developed at the University of Illinois at Urbana-Champaign (UIUC) specifically to overcome this hindrance to the scientific evaluation of MIR/MDL systems. Together with its subsidiary Human Use of Music Information Retrieval Systems (HUMIRS) project, IMIRSEL will allow MIR/MDL researchers access to the standardized large-scale collection of copyright-sensitive music materials and standardized test queries being housed at UIUC's National Center for Supercomputing Applications (NCSA). Virtual Research Labs (VRL), based upon NCSA's Data-to-Knowledge (D2K) tool set, are being developed through which MIR/MDL researchers will interact with the music materials under a "trusted code" security model.
Estimating standard errors in feature network models.
Frank, Laurence E; Heiser, Willem J
2007-05-01
Feature network models are graphical structures that represent proximity data in a discrete space while using the same formalism that is the basis of least squares methods employed in multidimensional scaling. Existing methods to derive a network model from empirical data only give the best-fitting network and yield no standard errors for the parameter estimates. The additivity properties of networks make it possible to consider the model as a univariate (multiple) linear regression problem with positivity restrictions on the parameters. In the present study, both theoretical and empirical standard errors are obtained for the constrained regression parameters of a network model with known features. The performance of both types of standard error is evaluated using Monte Carlo techniques.
Shaida, Nadeem; Priest, Andrew N; See, T C; Winterbottom, Andrew P; Graves, Martin J; Lomas, David J
2017-06-01
To evaluate the diagnostic performance of velocity- and acceleration-sensitized noncontrast-enhanced magnetic resonance angiography (NCE-MRA) of the infrageniculate arteries using contrast-enhanced MRA (CE-MRA) as a reference standard. Twenty-four patients with symptoms of peripheral arterial disease were recruited. Each patient's infrageniculate arterial tree was examined using a velocity-dependent flow-sensitized dephasing (VEL-FSD) technique, an acceleration-dependent (ACC-FSD) technique, and our conventional CE-MRA technique performed at 1.5T. The images were independently reviewed by two experienced vascular radiologists, who evaluated each vessel segment to assess visibility, diagnostic confidence, venous contamination, and detection of pathology. In all, 432 segments were evaluated by each of the three techniques by each reader in total. Overall diagnostic confidence was rated as moderate or high in 98.5% of segments with CE-MRA, 92.1% with VEL-FSD, and 79.9% with ACC-FSD. No venous contamination was seen in 96% of segments with CE-MRA, 72.2% with VEL-FSD, and 85.8% with ACC-FSD. Per-segment, per-limb, and per-patient sensitivities for detecting significant stenotic disease were 63.4%, 73%, and 92%, respectively, for ACC-FSD, and 65.3%, 87.2%, and 96% for VEL-FSD, and as such no significant statistical change was detected using McNemar's chi-squared test with P-values of 1.00, 0.13, and 0.77 obtained, respectively. Flow-dependent NCE-MRA techniques may have a role to play in evaluation of patients with peripheral vascular disease. Increased sensitivity of a velocity-based technique compared to an acceleration-based technique comes at the expense of greater venous contamination. 2J. Technical Efficacy: Stage 2 J. MAGN. RESON. IMAGING 2017;45:1846-1853. © 2016 International Society for Magnetic Resonance in Medicine.
Development, standardization, and validation of analytical methods provides state-of-the-science
techniques to evaluate the presence, or absence, of select PPCPs in biosolids. This research
provides the approaches, methods, and tools to assess the exposures and redu...
Language Assessment Course: Structure, Delivery and Learning Outcomes
ERIC Educational Resources Information Center
Solnyshkina, Marina I.; Solovova, Elena N.; Harkova, Elena V.; Kiselnikov, Aleksander S.
2016-01-01
Aimed at developing methods, tools and techniques for delivery and evaluation of an educational module, this article addresses the needs of academicians restructuring, adjusting and altering their curricula to meet European Higher Education Area standards. The paper focuses on two pressing issues -- the applicability of and adjustment to European…
Molecular Iodine Fluorescence Using a Green Helium-Neon Laser
ERIC Educational Resources Information Center
Williamson, J. Charles
2011-01-01
Excitation of molecular iodine vapor with a green (543.4 nm) helium-neon laser produces a fluorescence spectrum that is well suited for the upper-level undergraduate physical chemistry laboratory. Application of standard evaluation techniques to the spectrum yields ground electronic-state molecular parameters in good agreement with literature…
Evaluating the Skill of Students to Determine Soil Morphology Characteristics
ERIC Educational Resources Information Center
Post, Donald F.; Parikh, Sanjai J.; Papp, Rae Ann; Ferriera, Laerta
2006-01-01
Precise and accurate pedon descriptions prepared by field scientists using standard techniques with defined terminology and methodology are essential in describing soil pedons. The accuracy of field measurements generally are defined in terms of how well they agree with objective criteria (e.g., laboratory analysis), such as mechanical analysis…
ERIC Educational Resources Information Center
Okazaki, Shintaro; Alonso Rivas, Javier
2002-01-01
Discussion of research methodology for evaluating the degree of standardization in multinational corporations' online communication strategies across differing cultures focuses on a research framework for cross-cultural comparison of corporate Web pages, applying traditional advertising content study techniques. Describes pre-tests that examined…
DEVELOPMENT OF A FISH INDEX OF BIOTIC INTEGRITY FOR ASSESSING WADEABLE STREAMS IN WEST VIRGINIA
We used Environmental Monitoring Assessment Program (EMAP) data from the Mid-Atlantic Highlands Assessment (MAHA) to develop an Index of Biotic Integrity (IBI) for West Virginia (WV). Standard techniques were used to evaluate a candidate pool of 58 fish assemblage metrics. Resp...
Preoperative breast marking in reduction mammaplasty.
Gasperoni, C; Salgarello, M
1987-10-01
A simple method of preoperative marking for reduction mammaplasty is described. This method may be used in macromastias when the technique chosen implies a postoperative scar with the shape of an inverted T. The marking sequence follows standard steps, but the drawing is always different because it is a consequence of the shape of the breast. This marking method reduces the chance of making mistakes due to excessive personal evaluations or to the use of standard drawing patterns that may be not suitable for all breast shapes.
NASA Astrophysics Data System (ADS)
Anees, Amir; Khan, Waqar Ahmad; Gondal, Muhammad Asif; Hussain, Iqtadar
2013-07-01
The aim of this work is to make use of the mean of absolute deviation (MAD) method for the evaluation process of substitution boxes used in the advanced encryption standard. In this paper, we use the MAD technique to analyze some popular and prevailing substitution boxes used in encryption processes. In particular, MAD is applied to advanced encryption standard (AES), affine power affine (APA), Gray, Lui J., Residue Prime, S8 AES, SKIPJACK, and Xyi substitution boxes.
Improved ultrasonic standard reference blocks
NASA Technical Reports Server (NTRS)
Eitzen, D. G.
1975-01-01
A program to improve the quality, reproducibility and reliability of nondestructive testing through the development of improved ASTM-type ultrasonic reference standards is described. Reference blocks of aluminum, steel, and titanium alloys were considered. Equipment representing the state-of-the-art in laboratory and field ultrasonic equipment was obtained and evaluated. Some RF and spectral data on ten sets of ultrasonic reference blocks were taken as part of a task to quantify the variability in response from nominally identical blocks. Techniques for residual stress, preferred orientation, and microstructural measurements were refined and are applied to a reference block rejected by the manufacturer during fabrication in order to evaluate the effect of metallurgical condition on block response.
Thermal sensing of cryogenic wind tunnel model surfaces Evaluation of silicon diodes
NASA Technical Reports Server (NTRS)
Daryabeigi, K.; Ash, R. L.; Dillon-Townes, L. A.
1986-01-01
Different sensors and installation techniques for surface temperature measurement of cryogenic wind tunnel models were investigated. Silicon diodes were selected for further consideration because of their good inherent accuracy. Their average absolute temperature deviation in comparison tests with standard platinum resistance thermometers was found to be 0.2 K in the range from 125 to 273 K. Subsurface temperature measurement was selected as the installation technique in order to minimize aerodynamic interference. Temperature distortion caused by an embedded silicon diode was studied numerically.
Thermal sensing of cryogenic wind tunnel model surfaces - Evaluation of silicon diodes
NASA Technical Reports Server (NTRS)
Daryabeigi, Kamran; Ash, Robert L.; Dillon-Townes, Lawrence A.
1986-01-01
Different sensors and installation techniques for surface temperature measurement of cryogenic wind tunnel models were investigated. Silicon diodes were selected for further consideration because of their good inherent accuracy. Their average absolute temperature deviation in comparison tests with standard platinum resistance thermometers was found to be 0.2 K in the range from 125 to 273 K. Subsurface temperature measurement was selected as the installation technique in order to minimize aerodynamic interference. Temperature distortion caused by an embedded silicon diode was studied numerically.
PROPELLER technique to improve image quality of MRI of the shoulder.
Dietrich, Tobias J; Ulbrich, Erika J; Zanetti, Marco; Fucentese, Sandro F; Pfirrmann, Christian W A
2011-12-01
The purpose of this article is to evaluate the use of the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) technique for artifact reduction and overall image quality improvement for intermediate-weighted and T2-weighted MRI of the shoulder. One hundred eleven patients undergoing MR arthrography of the shoulder were included. A coronal oblique intermediate-weighted turbo spin-echo (TSE) sequence with fat suppression and a sagittal oblique T2-weighted TSE sequence with fat suppression were obtained without (standard) and with the PROPELLER technique. Scanning time increased from 3 minutes 17 seconds to 4 minutes 17 seconds (coronal oblique plane) and from 2 minutes 52 seconds to 4 minutes 10 seconds (sagittal oblique) using PROPELLER. Two radiologists graded image artifacts, overall image quality, and delineation of several anatomic structures on a 5-point scale (5, no artifact, optimal diagnostic quality; and 1, severe artifacts, diagnostically not usable). The Wilcoxon signed rank test was used to compare the data of the standard and PROPELLER images. Motion artifacts were significantly reduced in PROPELLER images (p < 0.001). Observer 1 rated motion artifacts with diagnostic impairment in one patient on coronal oblique PROPELLER images compared with 33 patients on standard images. Ratings for the sequences with PROPELLER were significantly better for overall image quality (p < 0.001). Observer 1 noted an overall image quality with diagnostic impairment in nine patients on sagittal oblique PROPELLER images compared with 23 patients on standard MRI. The PROPELLER technique for MRI of the shoulder reduces the number of sequences with diagnostic impairment as a result of motion artifacts and increases image quality compared with standard TSE sequences. PROPELLER sequences increase the acquisition time.
Analysis of calibration materials to improve dual-energy CT scanning for petrophysical applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ayyalasomavaiula, K.; McIntyre, D.; Jain, J.
2011-01-01
Dual energy CT-scanning is a rapidly emerging imaging technique employed in non-destructive evaluation of various materials. Although CT (Computerized Tomography) has been used for characterizing rocks and visualizing and quantifying multiphase flow through rocks for over 25 years, most of the scanning is done at a voltage setting above 100 kV for taking advantage of the Compton scattering (CS) effect, which responds to density changes. Below 100 kV the photoelectric effect (PE) is dominant which responds to the effective atomic numbers (Zeff), which is directly related to the photo electric factor. Using the combination of the two effects helps inmore » better characterization of reservoir rocks. The most common technique for dual energy CT-scanning relies on homogeneous calibration standards to produce the most accurate decoupled data. However, the use of calibration standards with impurities increases the probability of error in the reconstructed data and results in poor rock characterization. This work combines ICP-OES (inductively coupled plasma optical emission spectroscopy) and LIBS (laser induced breakdown spectroscopy) analytical techniques to quantify the type and level of impurities in a set of commercially purchased calibration standards used in dual-energy scanning. The Zeff data on the calibration standards with and without impurity data were calculated using the weighted linear combination of the various elements present and used in calculating Zeff using the dual energy technique. Results show 2 to 5% difference in predicted Zeff values which may affect the corresponding log calibrations. The effect that these techniques have on improving material identification data is discussed and analyzed. The workflow developed in this paper will translate to a more accurate material identification estimates for unknown samples and improve calibration of well logging tools.« less
Evaluating Trauma Sonography for Operational Use in the Microgravity Environment
NASA Technical Reports Server (NTRS)
Kirkpatrick, Andrew W.; Jones, Jeffrey A.; Sargsyan, Ashot; Hamilton, Douglas; Melton, Shannon; Beck, George; Nicolaou, Savvas; Campbell, Mark; Dulchavsky, Scott
2007-01-01
Sonography is the only medical imaging modality aboard the ISS, and is likely to remain the leading imaging modality in future human space flight programs. While trauma sonography (TS) has been well recognized for terrestrial trauma settings, the technique had to be evaluated for suitability in space flight prior to adopting it as an operational capability. The authors found the following four-phased evaluative approach applicable to this task: 1) identifying standard or novel terrestrial techniques for potential use in space medicine; 2) developing and testing these techniques with suggested modifications on the ground (1g) either in clinical settings or in animal models, as appropriate; 3) evaluating and refining the techniques in parabolic flight (0g); and 4) validating and implementing for clinical use in space. In Phase I of the TS project, expert opinion and literature review suggested TS to be a potential screening tool for trauma in space. In Phase II, animal models were developed and tested in ground studies, and clinical studies were carried out in collaborating trauma centers. In Phase III, animal models were flight-tested in the NASA KC-135 Reduced Gravity Laboratory. Preliminary results of the first three phases demonstrated potential clinical utility of TS in microgravity. Phase IV studies have begun to address crew training issues, on-board imaging protocols, and data transfer procedures necessary to offer the modified TS technique for space use.
Schellenberg, François; Humeau, Camille
2017-06-01
CDT is at present the most relevant routinely available biological marker of alcohol use and is widely used for screening and monitoring of patients. The lack of standardization leads to specific reference intervals for each procedure. The IFCC working group devoted to CDT demonstrated that the standardization is possible using calibrators assigned to the reference measurement procedure. In this study, we compare the capillary electrophoresis (CE) techniques Capillarys® CDT and Minicap® CDT (Sebia, Lisses, France) to the reference procedure before and after standardization in 126 samples covering the range of CDT measurement. Both capillary electrophoresis procedures show a high correlation (r=0,997) with the reference procedure and the concordance correlation coefficient evaluated according to Mc Bride is "almost perfect" (>0.997 for both CE procedures). The number of results with a relative difference higher than the acceptable difference limit is only 1 for Capillarys® CDT and 5 for Minicap® CDT. These results demonstrate the efficiency of the standardization of CDT measurements for both CE techniques from Sebia, achieved using calibrators assigned to the reference measurement procedure.
Ostrander, Roger V; McKinney, Bart I
2012-10-01
Studies suggest that arthroscopic repair techniques may have high recurrence rates for larger rotator cuff tears. A more anatomic repair may improve the success rate when performing arthroscopic rotator cuff repair. We hypothesized that a triple-row modification of the suture-bridge technique for rotator cuff repair would result in significantly more footprint contact area and pressure between the rotator cuff and the humeral tuberosity. Eighteen ovine infraspinatus tendons were repaired using 1 of 3 simulated arthroscopic techniques: a double-row repair, the suture-bridge technique, and a triple-row repair. The triple-row repair technique is a modification of the suture-bridge technique that uses an additional reducing anchor between the medial and lateral rows. Six samples were tested per group. Pressure-indicating film was used to measure the footprint contact area and pressure after each repair. The triple-row repair resulted in significantly more rotator cuff footprint contact area and contact pressure compared with the double-row technique and the standard suture-bridge technique. No statistical difference in contact area or contact pressure was found between the double-row technique and the suture-bridge technique. The triple-row technique for rotator cuff repair results in significantly more footprint contact area and contact pressure compared with the double-row and standard suture-bridge techniques. This more anatomic repair may improve the healing rate when performing arthroscopic rotator cuff repair. Copyright © 2012 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
Bronas, Ulf G; Hirsch, Alan T; Murphy, Timothy; Badenhop, Dalynn; Collins, Tracie C; Ehrman, Jonathan K; Ershow, Abby G; Lewis, Beth; Treat-Jacobson, Diane J; Walsh, M Eileen; Oldenburg, Niki; Regensteiner, Judith G
2009-11-01
The CLaudication: Exercise Vs Endoluminal Revascularization (CLEVER) study is the first randomized, controlled, clinical, multicenter trial that is evaluating a supervised exercise program compared with revascularization procedures to treat claudication. In this report, the methods and dissemination techniques of the supervised exercise training intervention are described. A total of 217 participants are being recruited and randomized to one of three arms: (1) optimal medical care; (2) aortoiliac revascularization with stent; or (3) supervised exercise training. Of the enrolled patients, 84 will receive supervised exercise therapy. Supervised exercise will be administered according to a protocol designed by a central CLEVER exercise training committee based on validated methods previously used in single center randomized control trials. The protocol will be implemented at each site by an exercise committee member using training methods developed and standardized by the exercise training committee. The exercise training committee reviews progress and compliance with the protocol of each participant weekly. In conclusion, a multicenter approach to disseminate the supervised exercise training technique and to evaluate its efficacy, safety and cost-effectiveness for patients with claudication due to peripheral arterial disease (PAD) is being evaluated for the first time in CLEVER. The CLEVER study will further establish the role of supervised exercise training in the treatment of claudication resulting from PAD and provide standardized methods for use of supervised exercise training in future PAD clinical trials as well as in clinical practice.
Proposal of a micromagnetic standard problem for ferromagnetic resonance simulations
NASA Astrophysics Data System (ADS)
Baker, Alexander; Beg, Marijan; Ashton, Gregory; Albert, Maximilian; Chernyshenko, Dmitri; Wang, Weiwei; Zhang, Shilei; Bisotti, Marc-Antonio; Franchin, Matteo; Hu, Chun Lian; Stamps, Robert; Hesjedal, Thorsten; Fangohr, Hans
2017-01-01
Nowadays, micromagnetic simulations are a common tool for studying a wide range of different magnetic phenomena, including the ferromagnetic resonance. A technique for evaluating reliability and validity of different micromagnetic simulation tools is the simulation of proposed standard problems. We propose a new standard problem by providing a detailed specification and analysis of a sufficiently simple problem. By analyzing the magnetization dynamics in a thin permalloy square sample, triggered by a well defined excitation, we obtain the ferromagnetic resonance spectrum and identify the resonance modes via Fourier transform. Simulations are performed using both finite difference and finite element numerical methods, with OOMMF and Nmag simulators, respectively. We report the effects of initial conditions and simulation parameters on the character of the observed resonance modes for this standard problem. We provide detailed instructions and code to assist in using the results for evaluation of new simulator tools, and to help with numerical calculation of ferromagnetic resonance spectra and modes in general.
Baylis, Sally A; Blümel, Johannes; Mizusawa, Saeko; Matsubayashi, Keiji; Sakata, Hidekatsu; Okada, Yoshiaki; Nübling, C Micha; Hanschmann, Kay-Martin O
2013-05-01
Nucleic acid amplification technique-based assays are a primary method for the detection of acute hepatitis E virus (HEV) infection, but assay sensitivity can vary widely. To improve interlaboratory results for the detection and quantification of HEV RNA, a candidate World Health Organization (WHO) International Standard (IS) strain was evaluated in a collaborative study involving 23 laboratories from 10 countries. The IS, code number 6329/10, was formulated by using a genotype 3a HEV strain from a blood donation, diluted in pooled human plasma and lyophilized. A Japanese national standard, representing a genotype 3b HEV strain, was prepared and evaluated in parallel. The potencies of the standards were determined by qualitative and quantitative assays. Assay variability was substantially reduced when HEV RNA concentrations were expressed relative to the IS. Thus, WHO has established 6329/10 as the IS for HEV RNA, with a unitage of 250,000 International Units per milliliter.
Mission Systems Open Architecture Science and Technology (MOAST) program
NASA Astrophysics Data System (ADS)
Littlejohn, Kenneth; Rajabian-Schwart, Vahid; Kovach, Nicholas; Satterthwaite, Charles P.
2017-04-01
The Mission Systems Open Architecture Science and Technology (MOAST) program is an AFRL effort that is developing and demonstrating Open System Architecture (OSA) component prototypes, along with methods and tools, to strategically evolve current OSA standards and technical approaches, promote affordable capability evolution, reduce integration risk, and address emerging challenges [1]. Within the context of open architectures, the program is conducting advanced research and concept development in the following areas: (1) Evolution of standards; (2) Cyber-Resiliency; (3) Emerging Concepts and Technologies; (4) Risk Reduction Studies and Experimentation; and (5) Advanced Technology Demonstrations. Current research includes the development of methods, tools, and techniques to characterize the performance of OMS data interconnection methods for representative mission system applications. Of particular interest are the OMS Critical Abstraction Layer (CAL), the Avionics Service Bus (ASB), and the Bulk Data Transfer interconnects, as well as to develop and demonstrate cybersecurity countermeasures techniques to detect and mitigate cyberattacks against open architecture based mission systems and ensure continued mission operations. Focus is on cybersecurity techniques that augment traditional cybersecurity controls and those currently defined within the Open Mission System and UCI standards. AFRL is also developing code generation tools and simulation tools to support evaluation and experimentation of OSA-compliant implementations.
NASA Astrophysics Data System (ADS)
Warren, Kevin Wilson
The Independent Sustain and Address (ISA) AC plasma panel is a flat, flicker-free, gas discharge type of display device. This display technology promises to reduce both the cost of manufacturing and operation of AC plasma displays. The ISA technology uses a vastly different mechanism to change the state of the display pixels than the standard AC plasma technology. This addressing mechanism is an exploitation of some of the natural characteristics associated with the plasma that can form during strong gas discharges. This thesis presents detailed data from experiments that were designed to evaluate and test the effectiveness of this mechanism. Through these experiments, the theory that the addressing methodology is based upon is developed and evaluated. These experiments show that the address margin windows for this technology are very large, minimally two to three times larger than the address margins for the standard XY AC plasma addressing techniques. New capabilities are also described, such as global brightness control for the ISA technology and a technique for increasing the addressing rate. These advances were designed into working prototypes and transferred to industry where there are currently commercial products available based upon these advances. A technique for implementing gray scale using some of these advances is also proposed.
Anding, Ralf; Smith, Phillip; de Jong, Tom; Constantinou, Christos; Cardozo, Linda; Rosier, Peter
2016-02-01
An ICI-RS Think Tank in 2014 discussed and evaluated the evidence for adding video and EMG to urodynamics (UDS) in children and also highlighted evidence gaps, with the aim of recommending further clinical and research protocols. A systematic analysis of the relevant literature for both X-ray (video) studies and electromyography, in combination with UDS in children with lower urinary tract dysfunction (LUTD), is summarized in this manuscript. The technical aspects are also critically reviewed. The body of evidence for the addition of X-ray (video) to filling and voiding cystometry and the evidence for the addition of pelvic muscle surface electromyography to urodynamics is scanty and insufficient. Standards are poor and variable so uncontrolled expert opinion dominates practice. The Think Tank has recommended that standardized ALARA ("As Low As Reasonably Achievable") principles should be adopted for video-urodynamics in children. The risk-benefit balance of X-ray exposure needs to be better evaluated and defined. Evaluation of images should be standardized and the association with pressure changes better analyzed and reported. Children's pelvic muscle surface electromyography technique should be standardized, technically improved, and its diagnostic relevance should be better evaluated. © 2016 Wiley Periodicals, Inc.
Reconsidering the H&E stain as the gold standard in assessing the depth of burn wounds.
Rosenberg, Arlene S
2017-12-01
While histological examination is considered by most as the gold standard for burn depth assessment, it has no practical use in the clinical setting. It has, however, been used in the research setting, as a mean for evaluating emerging techniques of depth measurement. Due to the limitations of the H&E stain, other stains have also been explored, such as lactate dehydrogenase (LDH), as presented in this issue, in "Improving the Histologic Characterization of Burn Depth." As the determination of burn depth is not a typical subject in dermatopathology, a summary of selected techniques and the possible role for the LDH stain in future research, is described herein. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Murad-Regadas, Sthela M; Regadas Filho, Francisco Sergio Pinheiro; Regadas, Francisco Sergio Pinheiro; Rodrigues, Lusmar Veras; de J R Pereira, Jacyara; da S Fernandes, Graziela Olivia; Dealcanfreitas, Iris Daiana; Mendonca Filho, Jose Jader
2014-02-01
New ultrasound techniques may complement current diagnostic tools, and combined techniques may help to overcome the limitations of individual techniques for the diagnosis of anorectal dysfunction. A high degree of agreement has been demonstrated between echodefecography (dynamic 3-dimensional anorectal ultrasonography) and conventional defecography. Our aim was to evaluate the ability of a combined approach consisting of dynamic 3-dimensional transvaginal and transrectal ultrasonography by using a 3-dimensional biplane endoprobe to assess posterior pelvic floor dysfunctions related to obstructed defecation syndrome in comparison with echodefecography. This was a prospective, observational cohort study conducted at a tertiary-care hospital. Consecutive female patients with symptoms of obstructed defecation were eligible. Each patient underwent assessment of posterior pelvic floor dysfunctions with a combination of dynamic 3-dimensional transvaginal and transrectal ultrasonography by using a biplane transducer and with echodefecography. Kappa (κ) was calculated as an index of agreement between the techniques. Diagnostic accuracy (sensitivity, specificity, and positive and negative predictive values) of the combined technique in detection of posterior dysfunctions was assessed with echodefecography as the standard for comparison. A total of 33 women were evaluated. Substantial agreement was observed regarding normal relaxation and anismus. In detecting the absence or presence of rectocele, the 2 methods agreed in all cases. Near-perfect agreement was found for rectocele grade I, grade II, and grade III. Perfect agreement was found for entero/sigmoidocele, with near-perfect agreement for rectal intussusception. Using echodefecography as the standard for comparison, we found high diagnostic accuracy of transvaginal and transrectal ultrasonography in the detection of posterior dysfunctions. This combined technique should be compared with other dynamic techniques and validated with conventional defecography. Dynamic 3-dimensional transvaginal and transrectal ultrasonography is a simple and fast ultrasound technique that shows strong agreement with echodefecography and may be used as an alternative method to assess patients with obstructed defecation syndrome.
Morikawa, Kei; Kurimoto, Noriaki; Inoue, Takeo; Mineshita, Masamichi; Miyazawa, Teruomi
2015-01-01
Endobronchial ultrasonography using a guide sheath (EBUS-GS) is an increasingly common bronchoscopic technique, but currently, no methods have been established to quantitatively evaluate EBUS images of peripheral pulmonary lesions. The purpose of this study was to evaluate whether histogram data collected from EBUS-GS images can contribute to the diagnosis of lung cancer. Histogram-based analyses focusing on the brightness of EBUS images were retrospectively conducted: 60 patients (38 lung cancer; 22 inflammatory diseases), with clear EBUS images were included. For each patient, a 400-pixel region of interest was selected, typically located at a 3- to 5-mm radius from the probe, from recorded EBUS images during bronchoscopy. Histogram height, width, height/width ratio, standard deviation, kurtosis and skewness were investigated as diagnostic indicators. Median histogram height, width, height/width ratio and standard deviation were significantly different between lung cancer and benign lesions (all p < 0.01). With a cutoff value for standard deviation of 10.5, lung cancer could be diagnosed with an accuracy of 81.7%. Other characteristics investigated were inferior when compared to histogram standard deviation. Histogram standard deviation appears to be the most useful characteristic for diagnosing lung cancer using EBUS images. © 2015 S. Karger AG, Basel.
A randomized trial of specialized versus standard neck physiotherapy in cervical dystonia.
Counsell, Carl; Sinclair, Hazel; Fowlie, Jillian; Tyrrell, Elaine; Derry, Natalie; Meager, Peter; Norrie, John; Grosset, Donald
2016-02-01
Anecdotal reports suggested that a specialized physiotherapy technique developed in France (the Bleton technique) improved primary cervical dystonia. We evaluated the technique in a randomized trial. A parallel-group, single-blind, two-centre randomized trial compared the specialized outpatient physiotherapy programme given by trained physiotherapists up to once a week for 24 weeks with standard physiotherapy advice for neck problems. Randomization was by a central telephone service. The primary outcome was the change in the total Toronto Western Spasmodic Torticollis Rating (TWSTR) scale, measured before any botulinum injections that were due, between baseline and 24 weeks evaluated by a clinician masked to treatment. Analysis was by intention-to-treat. 110 patients were randomized (55 in each group) with 24 week outcomes available for 84. Most (92%) were receiving botulinum toxin injections. Physiotherapy adherence was good. There was no difference between the groups in the change in TWSTR score over 24 weeks (mean adjusted difference 1.44 [95% CI -3.63, 6.51]) or 52 weeks (mean adjusted difference 2.47 [-2.72, 7.65]) nor in any of the secondary outcome measures (Cervical Dystonia Impact Profile-58, clinician and patient-rated global impression of change, mean botulinum toxin dose). Both groups showed large sustained improvements compared to baseline in the TWSTR, most of which occurred in the first four weeks. There were no major adverse events. Subgroup analysis suggested a centre effect. There was no statistically or clinically significant benefit from the specialized physiotherapy compared to standard neck physiotherapy advice but further trials are warranted. Copyright © 2015 Elsevier Ltd. All rights reserved.
Schaafsma, Joanna D; van der Graaf, Yolanda; Rinkel, Gabriel J E; Buskens, Erik
2009-12-01
The lack of a standard methodology in diagnostic research impedes adequate evaluation before implementation of constantly developing diagnostic techniques. We discuss the methodology of diagnostic research and underscore the relevance of decision analysis in the process of evaluation of diagnostic tests. Overview and conceptual discussion. Diagnostic research requires a stepwise approach comprising assessment of test characteristics followed by evaluation of added value, clinical outcome, and cost-effectiveness. These multiple goals are generally incompatible with a randomized design. Decision-analytic models provide an important alternative through integration of the best available evidence. Thus, critical assessment of clinical value and efficient use of resources can be achieved. Decision-analytic models should be considered part of the standard methodology in diagnostic research. They can serve as a valid alternative to diagnostic randomized clinical trials (RCTs).
Evaluation Criteria for Micro-CAI: A Psychometric Approach
Wallace, Douglas; Slichter, Mark; Bolwell, Christine
1985-01-01
The increased use of microcomputer-based instructional programs has resulted in a greater need for third-party evaluation of the software. This in turn has prompted the development of micro-CAI evaluation tools. The present project sought to develop a prototype instrument to assess the impact of CAI program presentation characteristics on students. Data analysis and scale construction was conducted using standard item reliability analyses and factor analytic techniques. Adequate subscale reliabilities and factor structures were found, suggesting that a psychometric approach to CAI evaluation may possess some merit. Efforts to assess the utility of the resultant instrument are currently underway.
Quantitative Technique for Comparing Simulant Materials through Figures of Merit
NASA Technical Reports Server (NTRS)
Rickman, Doug; Hoelzer, Hans; Fourroux, Kathy; Owens, Charles; McLemore, Carole; Fikes, John
2007-01-01
The 1989 workshop report entitled Workshop on Production and Uses of Simulated Lunar Materials and the Lunar Regolith Simulant Materials: Recommendations for Standardization, Production, and Usage, NASA Technical Publication both identified and reinforced a need for a set of standards and requirements for the production and usage of the Lunar simulant materials. As NASA prepares to return to the Moon, and set out to Mars, a set of early requirements have been developed for simulant materials and the initial methods to produce and measure those simulants have been defined. Addressed in the requirements document are: 1) a method for evaluating the quality of any simulant of a regolith, 2) the minimum characteristics for simulants of Lunar regolith, and 3) a method to produce simulants needed for NASA's Exploration mission. As an extension of the requirements document a method to evaluate new and current simulants has been rigorously defined through the mathematics of Figures of Merit (FoM). Requirements and techniques have been developed that allow the simulant provider to compare their product to a standard reference material through Figures of Merit. Standard reference material may be physical material such as the Apollo core samples or material properties predicted for any landing site. The simulant provider is not restricted to providing a single "high fidelity" simulant, which may be costly to produce. The provider can now develop "lower fidelity" simulants for engineering applications such as drilling and mobility applications.
Navigation bronchoscopy for diagnosis and small nodule location
Muñoz-Largacha, Juan A.; Litle, Virginia R.
2017-01-01
Lung cancer continues to be the most common cause of cancer death. Screening programs for high risk patients with the use of low-dose computed tomography (CT) has led to the identification of small lung lesions that were difficult to identify using previous imaging modalities. Electromagnetic navigational bronchoscopy (ENB) is a novel technique that has shown to be of great utility during the evaluation of small, peripheral lesions, that would otherwise be challenging to evaluate with conventional bronchoscopy. The diagnostic yield of navigational bronchoscopy however is highly variable, with reports ranging from 59% to 94%. This variability suggests that well-defined selection criteria and standardized protocols for the use of ENB are lacking. Despite this variability, we believe that this technique is a useful tool evaluating small peripheral lung lesions when patients are properly selected. PMID:28446971
Robust tuning of robot control systems
NASA Technical Reports Server (NTRS)
Minis, I.; Uebel, M.
1992-01-01
The computed torque control problem is examined for a robot arm with flexible, geared, joint drive systems which are typical in many industrial robots. The standard computed torque algorithm is not directly applicable to this class of manipulators because of the dynamics introduced by the joint drive system. The proposed approach to computed torque control combines a computed torque algorithm with torque controller at each joint. Three such control schemes are proposed. The first scheme uses the joint torque control system currently implemented on the robot arm and a novel form of the computed torque algorithm. The other two use the standard computed torque algorithm and a novel model following torque control system based on model following techniques. Standard tasks and performance indices are used to evaluate the performance of the controllers. Both numerical simulations and experiments are used in evaluation. The study shows that all three proposed systems lead to improved tracking performance over a conventional PD controller.
Microplastics in sediments: A review of techniques, occurrence and effects.
Van Cauwenberghe, Lisbeth; Devriese, Lisa; Galgani, François; Robbens, Johan; Janssen, Colin R
2015-10-01
Microplastics are omnipresent in the marine environment and sediments are hypothesized to be major sinks of these plastics. Here, over 100 articles spanning the last 50 year are reviewed with following objectives: (i) to evaluate current microplastic extraction techniques, (ii) to discuss the occurrence and worldwide distribution of microplastics in sediments, and (iii) to make a comprehensive assessment of the possible adverse effects of this type of pollution to marine organisms. Based on this review we propose future research needs and conclude that there is a clear need for a standardized techniques, unified reporting units and more realistic effect assessments. Copyright © 2015 Elsevier Ltd. All rights reserved.
A straightforward experimental method to evaluate the Lamb-Mössbauer factor of a 57Co/Rh source
NASA Astrophysics Data System (ADS)
Spina, G.; Lantieri, M.
2014-01-01
In analyzing Mössbauer spectra by means of the integral transmission function, a correct evaluation of the recoilless fs factor of the source at the position of the sample is needed. A novel method to evaluate fs for a 57Co source is proposed. The method uses the standard transmission experimental set up and it does not need further measurements but the ones that are mandatory in order to center the Mössbauer line and to calibrate the Mössbauer transducer. Firstly, the background counts are evaluated by collecting a standard Multi Channel Scaling (MCS) spectrum of a tick metal iron foil absorber and two Pulse Height Analysis (PHA) spectra with the same life-time and setting the maximum velocity of the transducer at the same value of the MCS spectrum. Secondly, fs is evaluated by fitting the collected MCS spectrum throughout the integral transmission approach. A test of the suitability of the technique is presented, too.
Villamonte-Chevalier, A; van Bree, H; Broeckx, Bjg; Dingemanse, W; Soler, M; Van Ryssen, B; Gielen, I
2015-09-25
Diagnostic imaging is essential to assess the lame patient; lesions of the elbow joint have traditionally been evaluated radiographically, however computed tomography (CT) has been suggested as a useful technique to diagnose various elbow pathologies. The primary objective of this study was to determine the sensitivity and specificity of CT to assess medial coronoid disease (MCD), using arthroscopy as gold standard. The secondary objective was to ascertain the radiographic sensitivity and specificity for MCD compared with CT. For this study 180 elbow joints were assessed, of which 141 had been examined with radiography, CT and arthroscopy; and 39 joints, had radiographic and CT assessment. Sensitivity and specificity were calculated for CT and radiographic findings using available statistical software. Sensitivity and specificity of CT using arthroscopy as gold standard resulted in high values for sensitivity (100 %) and specificity (93 %) for the assessment of MCD. For the radiographic evaluation, a sensitivity of 98 % and specificity of 64 - 69 % using CT as the technique of reference, were found. These results suggest that in case of doubt during radiographic assessment, CT could be used as a non-invasive technique to assess the presence of MCD. Based on the high sensitivity and specificity obtained in this study it has been considered that CT, rather than arthroscopy, is the preferred noninvasive technique to assess MCD lesions of the canine elbow joint.
NASA Astrophysics Data System (ADS)
Wang, H. L.; Han, W.; Xu, M.
2011-12-01
Measurement of the water flow rate in microchannel has been one of the hottest points in the applications of microfluidics, medical, biological, chemical analyses and so on. In this study, the scanning microscale particle image velocimetry (scanning micro-PIV) technique is used for the measurements of water flow rates in a straight microchannel of 200μm width and 60μm depth under the standard flow rates ranging from 2.481μL/min to 8.269μL/min. The main effort of this measurement technique is to obtain three-dimensional velocity distribution on the cross sections of microchannel by measuring velocities of the different fluid layers along the out-of-plane direction in the microchannel, so the water flow rates can be evaluated from the discrete surface integral of velocities on the cross section. At the same time, the three-dimensional velocity fields in the measured microchannel are simulated numerically using the FLUENT software in order to verify the velocity accuracy of measurement results. The results show that the experimental values of flow rates are well consistent to the standard flow rates input by the syringe pump and the compared results between numerical simulation and experiment are consistent fundamentally. This study indicates that the micro-flow rate evaluated from three-dimensional velocity by the scanning micro-PIV technique is a promising method for the micro-flow rate research.
Accuracy metrics for judging time scale algorithms
NASA Technical Reports Server (NTRS)
Douglas, R. J.; Boulanger, J.-S.; Jacques, C.
1994-01-01
Time scales have been constructed in different ways to meet the many demands placed upon them for time accuracy, frequency accuracy, long-term stability, and robustness. Usually, no single time scale is optimum for all purposes. In the context of the impending availability of high-accuracy intermittently-operated cesium fountains, we reconsider the question of evaluating the accuracy of time scales which use an algorithm to span interruptions of the primary standard. We consider a broad class of calibration algorithms that can be evaluated and compared quantitatively for their accuracy in the presence of frequency drift and a full noise model (a mixture of white PM, flicker PM, white FM, flicker FM, and random walk FM noise). We present the analytic techniques for computing the standard uncertainty for the full noise model and this class of calibration algorithms. The simplest algorithm is evaluated to find the average-frequency uncertainty arising from the noise of the cesium fountain's local oscillator and from the noise of a hydrogen maser transfer-standard. This algorithm and known noise sources are shown to permit interlaboratory frequency transfer with a standard uncertainty of less than 10(exp -15) for periods of 30-100 days.
van der Laan, Hans Paul; Dolsma, Wil V; Maduro, John H; Korevaar, Erik W; Hollander, Miranda; Langendijk, Johannes A
2007-07-15
To compare the target coverage and normal tissue dose with the simultaneously integrated boost (SIB) and the sequential boost technique in breast cancer, and to evaluate the incidence of acute skin toxicity in patients treated with the SIB technique. Thirty patients with early-stage left-sided breast cancer underwent breast-conserving radiotherapy using the SIB technique. The breast and boost planning target volumes (PTVs) were treated simultaneously (i.e., for each fraction, the breast and boost PTVs received 1.81 Gy and 2.3 Gy, respectively). Three-dimensional conformal beams with wedges were shaped and weighted using forward planning. Dose-volume histograms of the PTVs and organs at risk with the SIB technique, 28 x (1.81 + 0.49 Gy), were compared with those for the sequential boost technique, 25 x 2 Gy + 8 x 2 Gy. Acute skin toxicity was evaluated for 90 patients treated with the SIB technique according to Common Terminology Criteria for Adverse Events, version 3.0. PTV coverage was adequate with both techniques. With SIB, more efficiently shaped boost beams resulted in smaller irradiated volumes. The mean volume receiving > or =107% of the breast dose was reduced by 20%, the mean volume outside the boost PTV receiving > or =95% of the boost dose was reduced by 54%, and the mean heart and lung dose were reduced by 10%. Of the evaluated patients, 32.2% had Grade 2 or worse toxicity. The SIB technique is proposed for standard use in breast-conserving radiotherapy because of its dose-limiting capabilities, easy implementation, reduced number of treatment fractions, and relatively low incidence of acute skin toxicity.
Full-Field Strain Methods for Investigating Failure Mechanisms in Triaxial Braided Composites
NASA Technical Reports Server (NTRS)
Littell, Justin D.; Binienda, Wieslaw K.; Goldberg, Robert K.; Roberts, Gary D.
2008-01-01
Recent advancements in braiding technology have led to commercially viable manufacturing approaches for making large structures with complex shape out of triaxial braided composite materials. In some cases, the static load capability of structures made using these materials has been higher than expected based on material strength properties measured using standard coupon tests. A more detailed investigation of deformation and failure processes in large-unit-cell-size triaxial braid composites is needed to evaluate the applicability of standard test methods for these materials and to develop alternative testing approaches. This report presents some new techniques that have been developed to investigate local deformation and failure using digital image correlation techniques. The methods were used to measure both local and global strains during standard straight-sided coupon tensile tests on composite materials made with 12- and 24-k yarns and a 0 /+60 /-60 triaxial braid architecture. Local deformation and failure within fiber bundles was observed and correlations were made between these local failures and global composite deformation and strength.
Milosevic, Matija; McConville, Kristiina M Valter
2012-01-01
Operation of handheld power tools results in exposure to hand-arm vibrations, which over time lead to numerous health complications. The objective of this study was to evaluate protective equipment and working techniques for the reduction of vibration exposure. Vibration transmissions were recorded during different work techniques: with one- and two-handed grip, while wearing protective gloves (standard, air and anti-vibration gloves) and while holding a foam-covered tool handle. The effect was examined by analyzing the reduction of transmitted vibrations at the wrist. The vibration transmission was recorded with a portable device using a triaxial accelerometer. The results suggest large and significant reductions of vibration with appropriate safety equipment. Reductions of 85.6% were achieved when anti-vibration gloves were used. Our results indicated that transmitted vibrations were affected by several factors and could be measured and significantly reduced.
Application and use of spinal immobilization devices in zero-gravity flight
NASA Technical Reports Server (NTRS)
Krupa, Debra T.; Gosbee, John; Billica, Roger; Boyce, Joey B.
1991-01-01
A KC-135 parabolic flight was performed for the purpose of evaluation of spinal immobilization techniques in microgravity. The flight followed the standard 40 parabola profile with four NASA/KRUG experimenters involved. One performed as coordinator/recorder, one as test subject, and two as the Crew Medical Officers (CMO). The flight was to evaluate the application of spinal immobilization devices and techniques in microgravity as are performed during initial stabilization or patient transport scenarios. The sequence of detail for examination of the following objectives included: attempted cervical spine immobilization with all free floating, the patient restrained to the floor, various hand positioning techniques; c-collar placement; Kendrick Extrication Device (KED) application with various restraints for patient and CMO; patient immobilization and transport using the KED; patient transported on KED and spine board. Observations for each task are included. Major conclusions and issues are also included.
Neutron activation analysis of certified samples by the absolute method
NASA Astrophysics Data System (ADS)
Kadem, F.; Belouadah, N.; Idiri, Z.
2015-07-01
The nuclear reactions analysis technique is mainly based on the relative method or the use of activation cross sections. In order to validate nuclear data for the calculated cross section evaluated from systematic studies, we used the neutron activation analysis technique (NAA) to determine the various constituent concentrations of certified samples for animal blood, milk and hay. In this analysis, the absolute method is used. The neutron activation technique involves irradiating the sample and subsequently performing a measurement of the activity of the sample. The fundamental equation of the activation connects several physical parameters including the cross section that is essential for the quantitative determination of the different elements composing the sample without resorting to the use of standard sample. Called the absolute method, it allows a measurement as accurate as the relative method. The results obtained by the absolute method showed that the values are as precise as the relative method requiring the use of standard sample for each element to be quantified.
Abu-Tahun, Ibrahim; El-Ma'aita, Ahmad; Khraisat, Ameen
2016-08-01
The aim of this study was to report the satisfaction of fifth year undergraduate students on the clinical use of rotary endodontic preparation compared with stainless steel standard technique and to evaluate the impact of rotary nickel-titanium instruments on undergraduate teaching. This study was carried out by the fifth year undergraduate students attending peer review sessions as a part of their training program using a questionnaire to assess their satisfaction with these two techniques. The overall results indicated a statistically significant satisfaction of the undergraduate students with the use of the nickel-titanium system (P < 0.001) compared to stainless steel standard technique. Under the conditions of this study, the results showed a positive acceptance and consensus among novice dental students regarding the use of ProTaper rotary files and the need for undergraduate teaching of rotary nickel-titanium systems in Jordan. © 2015 Australian Society of Endodontology Inc.
Advancements in optical techniques and imaging in the diagnosis and management of bladder cancer.
Rose, Tracy L; Lotan, Yair
2018-03-01
Accurate detection and staging is critical to the appropriate management of urothelial cancer (UC). The use of advanced optical techniques during cystoscopy is becoming more widespread to prevent recurrent nonmuscle invasive bladder cancer. Standard of care for muscle-invasive UC includes the use of computed tomography and/or magnetic resonance imaging, but staging accuracy of these tests remains imperfect. Novel imaging modalities are being developed to improve current test performance. Positron emission tomography/computed tomography has a role in the initial evaluation of select patients with muscle-invasive bladder cancer and in disease recurrence in some cases. Several novel immuno-positron emission tomography tracers are currently in development to address the inadequacy of current imaging modalities for monitoring of tumor response to newer immune-based treatments. This review summaries the current standards and recent advances in optical techniques and imaging modalities in localized and metastatic UC. Copyright © 2018 Elsevier Inc. All rights reserved.
Molloi, Sabee; Ding, Huanjun; Feig, Stephen
2015-01-01
Purpose The purpose of this study was to compare the precision of mammographic breast density measurement using radiologist reader assessment, histogram threshold segmentation, fuzzy C-mean segmentation and spectral material decomposition. Materials and Methods Spectral mammography images from a total of 92 consecutive asymptomatic women (50–69 years old) who presented for annual screening mammography were retrospectively analyzed for this study. Breast density was estimated using 10 radiologist reader assessment, standard histogram thresholding, fuzzy C-mean algorithm and spectral material decomposition. The breast density correlation between left and right breasts was used to assess the precision of these techniques to measure breast composition relative to dual-energy material decomposition. Results In comparison to the other techniques, the results of breast density measurements using dual-energy material decomposition showed the highest correlation. The relative standard error of estimate for breast density measurements from left and right breasts using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean algorithm and dual-energy material decomposition was calculated to be 1.95, 2.87, 2.07 and 1.00, respectively. Conclusion The results indicate that the precision of dual-energy material decomposition was approximately factor of two higher than the other techniques with regard to better correlation of breast density measurements from right and left breasts. PMID:26031229
Emerging Minimally Invasive Treatment Options for Male Lower Urinary Tract Symptoms.
Magistro, Giuseppe; Chapple, Christopher R; Elhilali, Mostafa; Gilling, Peter; McVary, Kevin T; Roehrborn, Claus G; Stief, Christian G; Woo, Henry H; Gratzke, Christian
2017-12-01
Lower urinary tract symptoms (LUTS) are one of the most common and troublesome nonmalignant conditions affecting quality of life in aging men. A spectrum of established medical and surgical options is available to provide relief of bothersome LUTS. Both the adverse events of medication and the morbidity with surgical treatment modalities have to be counterbalanced against efficacy. Novel minimally invasive treatment options aim to be effective, ideally to be performed in an ambulatory setting under local anaesthesia and to offer a more favourable safety profile than existing reference techniques. A comprehensive, narrative review of novel minimally invasive treatment modalities for the management of male LUTS due to benign prostatic enlargement is presented. Medline, PubMed, Cochrane database, and Embase were screened for randomised controlled trials (RCTs), clinical trials, and reviews on novel minimally invasive treatment options for male LUTS due to benign prostatic enlargement. With regard to newly devised intraprostatic injectables (botulinum neurotoxin A, NX1207, PRX302), PRX302 is currently the only substance that was superior to placebo in a phase 3 RCT providing proof of efficacy and safety. The prostatic urethral lift technique has been evaluated in several phase 3 trials showing rapid and durable relief of LUTS without compromising sexual function in carefully selected patients without a prominent median lobe. The first clinical experience of the temporary implantable nitinol device demonstrated that implantation of this novel device is a safe procedure, easy, and fast to perform. Further studies are required to evaluate efficacy, durability, and to define appropriate patient selection. New ablative approaches like the image guided robotic waterjet ablation (AquaBeam) or procedures based on convective water vapour energy (Rezūm) are in the early stages of development. Prostatic artery embolization performed by interventional radiologists at specialised centres shows a high technical success rate in the treatment of bothersome LUTS. However, a substantial clinical failure rate and a particular spectrum of complications not commonly seen after urologic interventions do occur and need to be critically evaluated. Initial promising clinical results on novel minimally invasive treatment options indicate efficacy comparable to standard techniques, often associated with a more favourable safety profile, in particular with preservation of sexual function. Many of these techniques are in their infancy and based on experience of new developments in the past. Further RCTs are required to evaluate efficacy, safety, and durability of novel techniques with long-term follow-up and careful evaluation of the selection criteria, which have been applied in clinical trials. The prostatic urethral lift is the only procedure with Level 1 evidence data and that can therefore be recommended for treatment of male LUTS in clinical practice for selected patients. Minimally invasive treatment options have been developed to provide relief of lower urinary tract symptoms comparable to standard surgical techniques with a more favourable safety profile. However, long-term clinical evaluation is still needed for most of these innovations before they can be recommended to be an effective replacement for standard surgical treatment. Copyright © 2017 European Association of Urology. Published by Elsevier B.V. All rights reserved.
Wang, Hongmei; Feng, Qing; Li, Ning; Xu, Sheng
2016-12-01
Limited information is available regarding the metal-ceramic bond strength of dental Co-Cr alloys fabricated by casting (CAST), computer numerical control (CNC) milling, and selective laser melting (SLM). The purpose of this in vitro study was to evaluate the metal-ceramic bond characteristics of 3 dental Co-Cr alloys fabricated by casting, computer numerical control milling, and selective laser melting techniques using the 3-point bend test (International Organization for Standardization [ISO] standard 9693). Forty-five specimens (25×3×0.5 mm) made of dental Co-Cr alloys were prepared by CAST, CNC milling, and SLM techniques. The morphology of the oxidation surface of metal specimens was evaluated by scanning electron microscopy (SEM). After porcelain application, the interfacial characterization was evaluated by SEM equipped with energy-dispersive spectrometry (EDS) analysis, and the metal-ceramic bond strength was assessed with the 3-point bend test. Failure type and elemental composition on the debonding interface were assessed by SEM/EDS. The bond strength was statistically analyzed by 1-way ANOVA and Tukey honest significant difference test (α=.05). The oxidation surfaces of the CAST, CNC, and SLM groups were different. They were porous in the CAST group but compact and irregular in the CNC and SLM groups. The metal-ceramic interfaces of the SLM and CNC groups showed excellent combination compared with those of the CAST group. The bond strength was 37.7 ±6.5 MPa for CAST, 43.3 ±9.2 MPa for CNC, and 46.8 ±5.1 MPa for the SLM group. Statistically significant differences were found among the 3 groups tested (P=.028). The debonding surfaces of all specimens exhibited cohesive failure mode. The oxidation surface morphologies and thicknesses of dental Co-Cr alloys are dependent on the different fabrication techniques used. The bond strength of all 3 groups exceed the minimum acceptable value of 25 MPa recommended by ISO 9693; hence, dental Co-Cr alloy fabricated with the SLM techniques could be a promising alternative for metal ceramic restorations. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
The role of laparoscopic Heller myotomy in the treatment of achalasia.
Zonca, P; Cambal, M; Labas, P; Hrbaty, B; Jacobi, C A
2014-01-01
To evaluate the results of laparoscopic Heller myotomy in our group of patients. A retrospective clinical trial was carried out to evaluate the indication, technique and controversies of laparoscopic Heller myotomy in the achalasia treatment. The following symptoms were evaluated prior and after Heller myotomy: dysphagia, heartburn, nausea/vomiting after meal and asthma/coughing. The patients were evaluated by the use of Likert score. Statistical analysis was performed by using Student t test. The intra-operative (operation time, intraoperative complications, blood loss, conversion rate), and peri-operative parameters (morbidity, mortality, hospital stay) were evaluated as well. The patients who underwent laparoscopic Heller myotomy were included in the trial. All patients were perioperatively managed by a multidisciplinary team. The evaluation of fourteen patients was performed (average age: 53.2 yrs., eleven men, two women, BMI 23.6 kg/m(2)). The patients were indicated for surgery in all of the stages (I-III). Previous semiconservative therapeutic modalities were performed in thirteen patients. The standard laparoscopic technique for Heller myotomy with semifundoplication was applied. All the observed symptoms were statistically improved after the surgery (p=0.05). The average operating time was 89 minutes. Intraoperative blood loss was below 20 ml. There was no conversion to open surgery. An average hospital stay was 4.3 days. Morbidity was 14.3 % and mortality 0 %. In one patient esophageal mucosa perforation was intra-operatively identified and sutured. Post-operative course in this patient was without any complications. The laparoscopic Heller myotomy has become the "gold standard" procedure for achalasia. It is an excellent method allowing precise operation technique with good visualization of the esophagogastric junction. The operation with this approach is safe, efficient, and with excellent reproducible operative results. The correct and early indication for surgery is crucial. The delayed diagnosis with a late indication for surgery is not an exemption (Tab. 2, Fig. 2, Ref. 36).
Barroso, Gerardo; Chaya, Miguel; Bolaños, Rubén; Rosado, Yadira; García León, Fernando; Ibarrola, Eduardo
2005-05-01
To evaluate sperm recovery and total sperm motility in three different sperm preparation techniques (density gradient, simple washing and swim-up). A total of 290 subjects were randomly evaluated from November 2001 to March 2003. The density gradient method required Isolate (upper and lower layers). Centrifugation was performed at 400 g for 10 minutes and evaluation was done using the Makler counting chamber. The simple washing method included the use of HTF-M complemented with 7.5% of SSS, with centrifugation at 250 g, obtaining at the end 0.5 mL of the sperm sample. The swim-up method required HTF-M complemented with 7.5% of SSS, with an incubation period of 60 minutes at 37 degrees C. The demographic characteristics evaluated through their standard error, 95% ICC, and 50th percentile were similar. The application of multiple comparison tests and analysis of variance showed significant differences between the sperm preparations before and after capacitation. It was observed a superior recovery rate with the density gradient and swim-up methods; nevertheless, the samples used for the simple washing method showed a diminished sperm recovery from the original sample. Sperm preparation techniques have become very useful in male infertility treatments allowing higher sperm recovery and motility rates. The seminal parameters evaluated from the original sperm sample will determine the best sperm preparation technique in those patients who require it.
Radiometry of water turbidity measurements
NASA Technical Reports Server (NTRS)
Mccluney, W. R.
1974-01-01
An examination of a number of measurements of turbidity reported in the literature reveals considerable variability in the definitions, units, and measurement techniques used. Many of these measurements differ radically in the optical quantity measured. The radiometric basis of each of the most common definitions of turbidity is examined. Several commercially available turbidimeters are described and their principles of operation are evaluated radiometrically. It is recommended that the term turbidity be restricted to measurements based upon the light scattered by the sample with that scattered by standard suspensions of known turbidity. It is also recommended that the measurement procedure be standardized by requiring the use of Formazin as the turbidity standardizing material and that the Formazin Turbidity Unit (FTU) be adopted as the standard unit of turbidity.
Surface contamination analysis technology team overview
NASA Technical Reports Server (NTRS)
Burns, H. Dewitt
1995-01-01
A team was established which consisted of representatives from NASA (Marshall Space Flight Center and Langley Research Center), Thiokol Corporation, the University of Alabama in Huntsville, AC Engineering, SAIC, Martin Marietta, and Aerojet. The team's purpose was to bring together the appropriate personnel to determine what surface inspection techniques were applicable to multiprogram bonding surface cleanliness inspection. In order to identify appropriate techniques and their sensitivity to various contaminant families, calibration standards were developed. Producing standards included development of consistent low level contamination application techniques. Oxidation was also considered for effect on inspection equipment response. Ellipsometry was used for oxidation characterization. Verification testing was then accomplished to show that selected inspection techniques could detect subject contaminants at levels found to be detrimental to critical bond systems of interest. Once feasibility of identified techniques was shown, selected techniques and instrumentation could then be incorporated into a multipurpose inspection head and integrated with a robot for critical surface inspection. Inspection techniques currently being evaluated include optically stimulated electron emission (OSEE); near infrared (NIR) spectroscopy utilizing fiber optics; Fourier transform infrared (FTIR) spectroscopy; and ultraviolet (UV) fluorescence. Current plans are to demonstrate an integrated system in MSFC's Productivity Enhancement Complex within five years from initiation of this effort in 1992 assuming appropriate funding levels are maintained. This paper gives an overview of work accomplished by the team and future plans.
NASA Technical Reports Server (NTRS)
Guasp, Edwin; Manzo, Michelle A.
1997-01-01
Secondary alkaline batteries, such as nickel-cadmium and silver-zinc, are commonly used for aerospace applications. The uniform evaluation and comparison of separator properties for these systems is dependent upon the measurement techniques. This manual presents a series of standard test procedures that can be used to evaluate, compare, and select separator materials for use in alkaline batteries. Detailed test procedures evaluating the following characteristics are included in this manual: physical measurements of thickness and area weight, dimensional stability measurements, electrolyte retention, resistivity, permeability as measured via bubble pressure, surface evaluation via SEM, chemical stability, and tensile strength.
The effect of various veneering techniques on the marginal fit of zirconia copings.
Torabi, Kianoosh; Vojdani, Mahroo; Giti, Rashin; Taghva, Masumeh; Pardis, Soheil
2015-06-01
This study aimed to evaluate the fit of zirconia ceramics before and after veneering, using 3 different veneering processes (layering, press-over, and CAD-on techniques). Thirty standardized zirconia CAD/CAM frameworks were constructed and divided into three groups of 10 each. The first group was veneered using the traditional layering technique. Press-over and CAD-on techniques were used to veneer second and third groups. The marginal gap of specimens was measured before and after veneering process at 18 sites on the master die using a digital microscope. Paired t-test was used to evaluate mean marginal gap changes. One-way ANOVA and post hoc tests were also employed for comparison among 3 groups (α=.05). Marginal gap of 3 groups was increased after porcelain veneering. The mean marginal gap values after veneering in the layering group (63.06 µm) was higher than press-over (50.64 µm) and CAD-on (51.50 µm) veneered groups (P<.001). Three veneering methods altered the marginal fit of zirconia copings. Conventional layering technique increased the marginal gap of zirconia framework more than pressing and CAD-on techniques. All ceramic crowns made through three different veneering methods revealed clinically acceptable marginal fit.
Maroto, A; Illescas, T; Meléndez, M; Arévalo, S; Rodó, C; Peiró, J L; Belfort, M; Cuxart, A; Carreras, E
2017-10-01
To assess the reliability of the interpretation of a new technique for the ultrasound evaluation of the level of neurological lesion in fetuses with myelomeningocele. Observational study including myelomeningocele fetuses, referred to our center for the sonographic assessment of the fetal lower-limb movements, made and recorded by an expert in Maternal-fetal medicine and a specialist in Rehabilitation. Two observers, with different levels of expertise and blinded to each other's results, interpreted each recorded scan two different times. The agreement for the segmental levels assigned between the observers and the gold standard, the inter-observer and intra-observer reproducibility were tested using the weighed Kappa (wκ) index. Twenty-eight scans were recorded and evaluated. The agreement between the observers and the gold standard remained constant for the expert observer (wκ = 0.82) and increased (wκ = 0.66-wκ = 0.72) for the other one. The inter-observer and the intra-observer variability for the expert observer were wκ = 0.72 and wκ = 0.94, respectively. The agreement for the prenatal evaluation of the segmental neurological level was excellent, after a short training period, for observers with different degrees of expertise. The interpretation of this technique is reproducible enough and this supports its value for the prediction of postnatal motor function in myelomeningocele fetuses.
Silva, A C; Varela, A S; Cardoso, T F; Silva, E F; Loebmann, D; Corcini, C D
2017-01-01
Erythrolamprus poecilogyrus sublineatus (Cope, 1860), is a species widely distributed in the Pampa Domain, occurring in Rio Grande do Sul, Argentina and Uruguay, mainlyin the pampa region. In the coastal region of southern Brazil this is serpent is considered one of the most abundant. The purpose of the present study is to describe the techniques of sperm evaluation in vitro for E. poecilogyrus sublineatus in the coastal plain of Rio Grande do Sul, Brazil. After laparatomy the efferent vases were collected and the semen was diluted in 1ml Beltsville Thawing Solution. The characteristics of motility, membrane integrity, mitochondria, acrosome, DNA, cell viability and cellular functionality were evaluated. Fluorescent probes were used for the evaluation of sperm structure in epifluorescence microscope. With the techniques described, it was possible to identify intact and injured cells, enabling the determination of cell characteristics for the spring season (October and November). It was observed in the analyses that 80% of sperm cells were mobile and that 84.1 ± 8.0% of sperm membranes were intact. The standards found were of 48 ± 13.8% of intact acrosome, 73.6 ± 6.0 of perfect DNA and of 91.8 ± 4.0 of functional mitochondria. Thus, these values from the sperm analysis can be used as standards for the species Erythrolamprus poecilogyrus sublineatus.
Shugars, D A; Trent, P J; Heymann, H O
1979-08-01
Two instructional strategies, the traditional lecture method and a standardized self-instructional (ACORDE) format, were compared for efficiency and perceived usefulness in a preclinical restorative dentistry technique course through the use of a posttest-only control group research design. Control and experimental groups were compared on (a) technique grades, (b) didactic grades, (c) amount of time spent, (d) student and faculty perceptions, and (e) observation of social dynamics. The results of this study demonstrated the effectiveness of Project ACORDE materials in teaching dental students, provided an example of applied research designed to test contemplated instructional innovations prior to use and used a method which highlighted qualitative, as well as quantitative, techniques for data gathering in applied research.
Locating Stardust-like Particles in Aerogel Using X-Ray Techniques
NASA Technical Reports Server (NTRS)
Jurewicz, A. J. G.; Jones, S. M.; Tsapin, A.; Mih, D. T.; Connolly, H. C., Jr.; Graham, G. A.
2003-01-01
Silica aerogel is the material that the spacecraft STARDUST is using to collect interstellar and cometary silicates. Anticipating the return of the samples to earth in January of 2006, MANY individual investigators and, especially, the investigators in NASA's SRLIDAP program are studying means of both in situ analysis of particles, as well as particle extraction. To help individual PI's with extraction of particles from aerogel in their own laboratories, we are exploring the use of standard laboratory x-ray equipment and commercial techniques for precisely locating specific particles in aerogel. We approached the evaluation of commercial x-ray techniques as follows. First, we determined the most appropriate detector for use with aerogel and particulates. Then, we compared and contrasted techniques useful for university laboratories.
NASA Astrophysics Data System (ADS)
Reed, David M.; Tortella, Bartholomew J.; Dolan, William V.; Pennino, Ralph P.; Treat, Michael R.
1993-05-01
The unprecedented rapid and successful adoption of laparoscopic cholecystectomy has prompted the evaluation of converting other standard open surgical procedures to a laparoscopic technique. A wide variety of laparoscopic acid reduction procedures have been successfully accomplished by groups in this country and abroad. Our group reviewed the literature on the many types of open peptic ulcer operations, as well as the ones performed laparoscopically. We elected to perfect the technique of posterior truncal vagotomy and anterior seromyotomy (PTVAS). After extensive animal laboratory work, we performed PTVAS on four patients with documented recurrent peptic ulcer disease. We describe our technique as it evolved and in particular note the usefulness of endoscopic esophageal transillumination. In addition, we report our results and discuss their implications.
Planar Laser Imaging of Sprays for Liquid Rocket Studies
NASA Technical Reports Server (NTRS)
Lee, W.; Pal, S.; Ryan, H. M.; Strakey, P. A.; Santoro, Robert J.
1990-01-01
A planar laser imaging technique which incorporates an optical polarization ratio technique for droplet size measurement was studied. A series of pressure atomized water sprays were studied with this technique and compared with measurements obtained using a Phase Doppler Particle Analyzer. In particular, the effects of assuming a logarithmic normal distribution function for the droplet size distribution within a spray was evaluated. Reasonable agreement between the instrument was obtained for the geometric mean diameter of the droplet distribution. However, comparisons based on the Sauter mean diameter show larger discrepancies, essentially because of uncertainties in the appropriate standard deviation to be applied for the polarization ratio technique. Comparisons were also made between single laser pulse (temporally resolved) measurements with multiple laser pulse visualizations of the spray.
Bujar, Magdalena; McAuslane, Neil; Walker, Stuart R; Salek, Sam
2017-01-01
Introduction: Although pharmaceutical companies, regulatory authorities, and health technology assessment (HTA) agencies have been increasingly using decision-making frameworks, it is not certain whether these enable better quality decision making. This could be addressed by formally evaluating the quality of decision-making process within those organizations. The aim of this literature review was to identify current techniques (tools, questionnaires, surveys, and studies) for measuring the quality of the decision-making process across the three stakeholders. Methods: Using MEDLINE, Web of Knowledge, and other Internet-based search engines, a literature review was performed to systematically identify techniques for assessing quality of decision making in medicines development, regulatory review, and HTA. A structured search was applied using key words and a secondary review was carried out. In addition, the measurement properties of each technique were assessed and compared. Ten Quality Decision-Making Practices (QDMPs) developed previously were then used as a framework for the evaluation of techniques identified in the review. Due to the variation in studies identified, meta-analysis was inappropriate. Results: This review identified 13 techniques, where 7 were developed specifically to assess decision making in medicines' development, regulatory review, or HTA; 2 examined corporate decision making, and 4 general decision making. Regarding how closely each technique conformed to the 10 QDMPs, the 13 techniques assessed a median of 6 QDMPs, with a mode of 3 QDMPs. Only 2 techniques evaluated all 10 QDMPs, namely the Organizational IQ and the Quality of Decision Making Orientation Scheme (QoDoS), of which only one technique, QoDoS could be applied to assess decision making of both individuals and organizations, and it possessed generalizability to capture issues relevant to companies as well as regulatory authorities. Conclusion: This review confirmed a general paucity of research in this area, particularly regarding the development and systematic application of techniques for evaluating quality decision making, with no consensus around a gold standard. This review has identified QoDoS as the most promising available technique for assessing decision making in the lifecycle of medicines and the next steps would be to further test its validity, sensitivity, and reliability.
Chen, Fu-Li; Lee, Albert
2016-03-01
The Taiwan Ministry of Health and Welfare and Ministry of Education launched the Health-Promoting School (HPS) program in 2002. One of the most significant barriers to evaluating HPS is the absence of adequate instruments. The main aim of this study is to develop the Taiwan Health-Promoting School Accreditation System (HPSAS) framework and then evaluate its accreditation effectiveness. The HPSAS accreditation standards were derived mainly from the World Health Organization (WHO) publication, WHO Health Promoting Schools: A Framework for Action in 2008 and the Taiwan School Health Act. Delphi technique and pilot test were used to confirm the availability and acceptability of the standards and procedures for HPSAS in 2011. After that, two rounds of school evaluations were completed in 2012 (214 participant schools) and 2014 (182 participant schools). The accreditation operation process included documentary reviews, national and international accredited commissioners conducted on-site visits. Descriptive analyses were used to indicate HPS award level distribution. The study established six key HPSAS standards. Each standard had at least two components; overall, there were 21 components and 47 scoring elements. Of the participating schools evaluated in 2012, four were at the gold, 14 silver, and 120 bronze levels, compared with five, 20, and 31, respectively, of schools evaluated in 2014. The study showed that schools at different award levels had different full-score rates in six standards. The schools at the gold level performed exceptionally well. The worst performance among the six standards at each award level was in the skill-based health curriculum. The HPSAS is an objective instrument used to evaluate the process and outcomes of the HPS program. In the future, combinations of different types of data (e.g. students' health behaviors, school climate, or teachers' health-teaching innovations) will enable further validation of the HPS effectiveness. © The Author(s) 2016.
Antigens to detect the acute phase of toxoplasmosis in pregnant women: standardized comparison.
Costa, Juan Gabriel; Vilariño, María Julia
2018-05-01
A key element in any diagnostic technique is the antigen (Ag), a biomarker, but this is usually a protein that has a function to the parasite. Some biological aspects of the Ags and of the Toxoplasma gondii can influence the effectiveness of the diagnosis, as well as the antibody isotype and the characteristics of the assay. A large number of papers have assessed different proteins to distinguish the phases of infection, but the 'indices of effectiveness' differ among reports. This work presents for the first time a summary of all the Ags that have been evaluated, with standardized measurements of sensitivity and specificity. These values were calculated with information presented in the papers on Ag evaluations to differentiate the infection phases.
Filippini, D; Tejle, K; Lundström, I
2005-08-15
The computer screen photo-assisted technique (CSPT), a method for substance classification based on spectral fingerprinting, which involves just a computer screen and a web camera as measuring platform is used here for the evaluation of a prospective enzyme-linked immunosorbent assay (ELISA). A anti-neutrophil cytoplasm antibodies (ANCA-ELISA) test, typically used for diagnosing patients suffering from chronic inflammatory disorders in the skin, joints, blood vessels and other tissues is comparatively tested with a standard microplate reader and CSPT, yielding equivalent results at a fraction of the instrumental costs. The CSPT approach is discussed as a distributed measuring platform allowing decentralized measurements in routine applications, whereas keeping centralized information management due to its natural network embedded operation.
Ben-Zvi, Tal; Hueber, Pierre-Alain; Abdollah, Firas; Liberman, Daniel; Bhojani, Naeem; Gautam, Gagan; Zorn, Kevin C
2013-02-01
To evaluate a hybrid technique involving GreenLight 120W HPS vapor incision tissue removal in prostate glands > 80 cc. Vapor incision technique (VIT) was performed in 25 consecutive men with a prostate > 80 cc by a single surgeon from May 2010 until September 2010. VIT involved adenoma incisions at 5 and 7-o'clock positions followed by 3, 9 and 12 o'clock down to the surgical capsule. Side-fire vaporization along the capsule excised transurethral resection of the prostate (TURP) like tissue strips for later retrieval. Functional evaluations were performed at 1 and 3 months. Outcomes and complications were compared retrospectively to baseline and a size matched- cohort of 25 men who previously underwent standard vaporization-only photoselective vaporization prostatectomy (PVP). The VIT and control subgroups were comparable. Mean laser time, operative time and energy usage were reduced in the VIT group compared to controls (35 min versus 48 min; 63 min versus 80 min; and 227 k versus 325 kJ respectively; all p < 0.05). At 3 months the VIT subgroup demonstrated improved Qmax and post void residual (PVR) (197% versus 173%, 88% versus 72%; all p < 0.05) compared to control. VIT showed a 68% reduction in mean preoperative PSA at 3 months compared to 50% for the control group (p<0.01). Hospital stay, catheterization time and complication rates were comparable. Our data demonstrates that VIT provides superior short term outcomes to standard HPS-PVP in men with prostate volumes > 80 cc. VIT appears to be more time-efficient, consumes less energy and obtains tissue for pathological evaluation. Further follow up is required to assess the durability of GreenLight HPS-VIT to PVP vaporization-only for large prostate glands.
Evaluation of modified Dennis parasitological technique for diagnosis of bovine fascioliasis.
Correa, Stefanya; Martínez, Yudy Liceth; López, Jessika Lissethe; Velásquez, Luz Elena
2016-02-23
Bovine fascioliasis causes important economic losses, estimated at COP$ 12,483 billion per year; its prevalence is 25% in dairy cattle. Parasitological techniques are required for it diagnosis. The Dennis technique, modified in 2002, is the one used in Colombia, but its sensitivity, specificity and validity are not known. To evaluate the validity and performance of the modified Dennis technique for diagnosis of bovine fascioliasis using as reference test the observation of parasites in the liver. We conducted a diagnostic evaluation study. We selected a convenience sample of discarded bovines sacrificed between March and June, 2013, in Frigocolanta for the study. We collected 25 g of feces from each animal and their liver and bile ducts were examined for Fasciola hepatica. The sensitivity, specificity, predictive positive value, predictive negative value, and validity index were calculated with 95% confidence intervals. The post-mortem evaluation was used as the gold standard. We analyzed 180 bovines. The sensitivity and specificity of the modified Dennis technique were 73.2% (95% CI=58.4% - 87.9%) and 84.2% (95% CI= 77.7% - 90.6%), respectively. The positive predictive value was 57.7% (95% CI= 43.3% - 72.1%) and the negative one 91.4% (95% CI= 86.2% - 96.6%). The prevalence of bovine fascioliasis was 22.8% (95% CI= 16.4% - 29.2%). The validity and the performance of the modified Dennis technique were higher than those of the traditional one, which makes it a good screening test for diagnosing fascioliasis for population and prevalence studies and during animal health campaigns.
Evaluation of AL-FEC performance for IP television services QoS
NASA Astrophysics Data System (ADS)
Mammi, E.; Russo, G.; Neri, A.
2010-01-01
The IP television services quality is a critical issue because of the nature of transport infrastructure. Packet loss is the main cause of service degradation in such kind of network platforms. The use of forward error correction (FEC) techniques in the application layer (AL-FEC), between the source of TV service (video server) and the user terminal, seams to be an efficient strategy to counteract packet losses alternatively or in addiction to suitable traffic management policies (only feasible in "managed networks"). A number of AL-FEC techniques have been discussed in literature and proposed for inclusion in TV over IP international standards. In this paper a performance evaluation of the AL-FEC defined in SMPTE 2022-1 standard is presented. Different typical events occurring in IP networks causing different types (in terms of statistic distribution) of IP packet losses have been studied and AL-FEC performance to counteract these kind of losses have been evaluated. The performed analysis has been carried out in view of fulfilling the TV services QoS requirements that are usually very demanding. For managed networks, this paper envisages a strategy to combine the use of AL-FEC with the set-up of a transport quality based on FEC packets prioritization. Promising results regard this kind of strategy have been obtained.
A novel method for simultaneous measurement of doped optical fiber parameters
NASA Astrophysics Data System (ADS)
Karimi, M.; Seraji, F. E.
2010-05-01
Simultaneous measurement technique of evaluating the doped optical fibers (DOF) parameters is a suitable scheme for DOF production industries. In this paper, we introduce a novel technique to characterize simultaneously the main parameters of DOF such as absorption and emission cross-sections (ACS, ECS), background loss coefficient (BLC), and low dopant concentration using the gain equation of DOFs. We used this new method to determine the ACS, ECS, BLC in a standard sample of Al-P-Erbium doped optical fiber. The results have been analyzed and compared with other reports.
Iterative metal artifact reduction: evaluation and optimization of technique.
Subhas, Naveen; Primak, Andrew N; Obuchowski, Nancy A; Gupta, Amit; Polster, Joshua M; Krauss, Andreas; Iannotti, Joseph P
2014-12-01
Iterative metal artifact reduction (IMAR) is a sinogram inpainting technique that incorporates high-frequency data from standard weighted filtered back projection (WFBP) reconstructions to reduce metal artifact on computed tomography (CT). This study was designed to compare the image quality of IMAR and WFBP in total shoulder arthroplasties (TSA); determine the optimal amount of WFBP high-frequency data needed for IMAR; and compare image quality of the standard 3D technique with that of a faster 2D technique. Eight patients with nine TSA underwent CT with standardized parameters: 140 kVp, 300 mAs, 0.6 mm collimation and slice thickness, and B30 kernel. WFBP, three 3D IMAR algorithms with different amounts of WFBP high-frequency data (IMARlo, lowest; IMARmod, moderate; IMARhi, highest), and one 2D IMAR algorithm were reconstructed. Differences in attenuation near hardware and away from hardware were measured and compared using repeated measures ANOVA. Five readers independently graded image quality; scores were compared using Friedman's test. Attenuation differences were smaller with all 3D IMAR techniques than with WFBP (p < 0.0063). With increasing high-frequency data, the attenuation difference increased slightly (differences not statistically significant). All readers ranked IMARmod and IMARhi more favorably than WFBP (p < 0.05), with IMARmod ranked highest for most structures. The attenuation difference was slightly higher with 2D than with 3D IMAR, with no significant reader preference for 3D over 2D. IMAR significantly decreases metal artifact compared to WFBP both objectively and subjectively in TSA. The incorporation of a moderate amount of WFBP high-frequency data and use of a 2D reconstruction technique optimize image quality and allow for relatively short reconstruction times.
Radiofrequency ablation versus electrocautery in tonsillectomy.
Hall, Daniel J; Littlefield, Philip D; Birkmire-Peters, Deborah P; Holtel, Michael R
2004-03-01
The objective of this study was to compare the safety, difficulty of removal, and postoperative pain profile of radiofrequency ablation versus standard electrocautery removal of tonsils. A prospective, blinded study was designed to remove 1 tonsil with each of the 2 methods. Time of operation, estimated blood loss, difficulty of operation, postoperative pain, rate of postoperative hemorrhage, and the patient's preferred technique were evaluated. The operating time was significantly longer (P < 0.007) and the patients reported significantly less pain (P < 0.001) with radiofrequency ablation. There were no differences in blood loss, difficulty of operation, or postoperative hemorrhage rates. The patients preferred the radiofrequency ablation technique (P < 0.001). Radiofrequency ablation is a viable method to remove tonsillar tissue. Operating time for this procedure will likely decrease with experience. There was significantly less pain reported with radiofrequency ablation compared with standard electrocautery.
O’Connell, Dylan P.; Thomas, David H.; Dou, Tai H.; Lamb, James M.; Feingold, Franklin; Low, Daniel A.; Fuld, Matthew K.; Sieren, Jered P.; Sloan, Chelsea M.; Shirk, Melissa A.; Hoffman, Eric A.; Hofmann, Christian
2015-01-01
Purpose: To demonstrate that a “5DCT” technique which utilizes fast helical acquisition yields the same respiratory-gated images as a commercial technique for regular, mechanically produced breathing cycles. Methods: Respiratory-gated images of an anesthetized, mechanically ventilated pig were generated using a Siemens low-pitch helical protocol and 5DCT for a range of breathing rates and amplitudes and with standard and low dose imaging protocols. 5DCT reconstructions were independently evaluated by measuring the distances between tissue positions predicted by a 5D motion model and those measured using deformable registration, as well by reconstructing the originally acquired scans. Discrepancies between the 5DCT and commercial reconstructions were measured using landmark correspondences. Results: The mean distance between model predicted tissue positions and deformably registered tissue positions over the nine datasets was 0.65 ± 0.28 mm. Reconstructions of the original scans were on average accurate to 0.78 ± 0.57 mm. Mean landmark displacement between the commercial and 5DCT images was 1.76 ± 1.25 mm while the maximum lung tissue motion over the breathing cycle had a mean value of 27.2 ± 4.6 mm. An image composed of the average of 30 deformably registered images acquired with a low dose protocol had 6 HU image noise (single standard deviation) in the heart versus 31 HU for the commercial images. Conclusions: An end to end evaluation of the 5DCT technique was conducted through landmark based comparison to breathing gated images acquired with a commercial protocol under highly regular ventilation. The techniques were found to agree to within 2 mm for most respiratory phases and most points in the lung. PMID:26133604
ESTABLISH AND STANDARDIZE METHODOLOGY FOR ...
Research is conducted to develop and standardize methods to detect and measure occurrence of human enteric viruses that cause waterborne disease. The viruses of concern include the emerging pathogens--hepatitis E virus and group B rotaviruses. Also of concern are the coxsackieviruses and echoviruses--two members of the Office of Water's Contaminant Candidate List (CCL). Under this task, indicators of fecal pollution are also being evaluated as to their importance in evaluating microbial water quality. Another focus of the research is to address the standardization, evaluation and promulgation of detection methods for bacterial viruses. Develop sensitive techniques to detect and identify emerging human waterborne pathogenic viruses and viruses on the CCL.Determine effectiveness of viral indicators to measure microbial quality in water matrices.Support activities: (a) culture and distribution of mammalian cells for Agency and scientific community research needs, (b) provide operator expertise for research requiring confocal and electron microscopy, (c) glassware cleaning, sterilization and biological waste disposal for the Cincinnati EPA facility, (d) operation of infectious pathogenic suite, (e) maintenance of walk-in constant temperature rooms and (f) provide Giardia cysts.
Zahed Zahedani, SM; Oshagh, M; Momeni Danaei, Sh; Roeinpeikar, SMM
2013-01-01
Statement of Problem: One of the major outcomes of orthodontic treatment is the apical root resorption of teeth moved during the treatment. Identifying the possible risk factors, are necessary for every orthodontist. Purpose: The aim of this study was to compare the rate of apical root resorption after fixed orthodontic treatment with standard edgewise and straight wire (MBT) method, and also to evaluate other factors effecting the rate of root resorption in orthodontic treatments. Materials and Method: In this study, parallel periapical radiographs of 127 patients imaging a total of 737 individual teeth, were collected. A total of 76 patients were treated by standard edgewise and 51 patients by straight wire method. The periapical radiographs were scanned and then the percentage of root resorption was calculated by Photoshop software. The data were analyzed by Paired-Samples t-test and the Generalized Linear Model adopting the SPSS 15.0. Results: In patients treated with straight wire method (MBT), mean root resorption was 18.26% compared to 14.82% in patients treated with standard edgewise technique (p< .05). Male patients had higher rate of root resorption,statistically significant (p< .05). Age at onset of treatment, duration of treatment, type of dental occlusion, premolar extractions and the use of intermaxillary elastics had no significant effect on the root resorption in this study. Conclusion: Having more root resorption in the straight wire method and less in the standard edgewise technique can be attributed to more root movement in pre-adjusted MBT technique due to the brackets employed in this method. PMID:24724131
Zahed Zahedani, Sm; Oshagh, M; Momeni Danaei, Sh; Roeinpeikar, Smm
2013-09-01
One of the major outcomes of orthodontic treatment is the apical root resorption of teeth moved during the treatment. Identifying the possible risk factors, are necessary for every orthodontist. The aim of this study was to compare the rate of apical root resorption after fixed orthodontic treatment with standard edgewise and straight wire (MBT) method, and also to evaluate other factors effecting the rate of root resorption in orthodontic treatments. In this study, parallel periapical radiographs of 127 patients imaging a total of 737 individual teeth, were collected. A total of 76 patients were treated by standard edgewise and 51 patients by straight wire method. The periapical radiographs were scanned and then the percentage of root resorption was calculated by Photoshop software. The data were analyzed by Paired-Samples t-test and the Generalized Linear Model adopting the SPSS 15.0. In patients treated with straight wire method (MBT), mean root resorption was 18.26% compared to 14.82% in patients treated with standard edgewise technique (p< .05). Male patients had higher rate of root resorption,statistically significant (p< .05). Age at onset of treatment, duration of treatment, type of dental occlusion, premolar extractions and the use of intermaxillary elastics had no significant effect on the root resorption in this study. Having more root resorption in the straight wire method and less in the standard edgewise technique can be attributed to more root movement in pre-adjusted MBT technique due to the brackets employed in this method.
Recent advances in rapid and non-destructive assessment of meat quality using hyperspectral imaging
NASA Astrophysics Data System (ADS)
Tao, Feifei; Ngadi, Michael
2016-05-01
Meat is an important food item in human diet. Its production and consumption has greatly increased in the last decades with the development of economies and improvement of peoples' living standards. However, most of the traditional methods for evaluation of meat quality are time-consuming, laborious, inconsistent and destructive to samples, which make them not appropriate for a fast-paced production and processing environment. Development of innovative and non-destructive optical sensing techniques to facilitate simple, fast, and accurate evaluation of quality are attracting increasing attention in the food industry. Hyperspectral imaging is one of the promising techniques. It integrates the combined merits of imaging and spectroscopic techniques. This paper provides a comprehensive review on recent advances in evaluation of the important quality attributes of meat including color, marbling, tenderness, pH, water holding capacity, and also chemical composition attributes such as moisture content, protein content and fat content in pork, beef and lamb. In addition, the future potential applications and trends of hyperspectral imaging are also discussed in this paper.
Environmental Development Plan (EDP). Enhanced gas recovery, FY 1977
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1978-03-01
This Enhanced Gcs Recovery EDP addresses the environmental impacts of enhanced gas recovery processes in shale and sandstone, methane drainage from coalbeds, and methane recovery from geopressured aquifers. The EDP addresses planning in two basic areas: environmental research and environmental assessment. Environmental research can be categorized as follows: characterization of pollutants from EGR processes; selective application of monitoring and measuring techniques; evaluation of control/mitigation techniques; and evaluation of the synergistic impacts of the development of EGR techniques. Environmental assessment activities scheduled by EDP include: assessment of ecological impacts; assessment of socioeconomic effects; EIA/EIS preparation; evaluation of control technology needs; andmore » analysis of applicable and proposed emission, effluent, and health and safety standards. The EGR EDP includes an EGR technology overview (Section 2), a discussion of EGR environmental issues and requirements (Section 3), an environmental action plan (Section 4), an environmental management strategy for the EGR program (Section 5), and supporting appendices which present information on Federal legislation applicable to EGR technology, a summary of ongoing and completed research, and future research and assessment projects.« less
Quantitative Ultrasound for Nondestructive Characterization of Engineered Tissues and Biomaterials
Dalecki, Diane; Mercado, Karla P.; Hocking, Denise C.
2015-01-01
Non-invasive, non-destructive technologies for imaging and quantitatively monitoring the development of artificial tissues are critical for the advancement of tissue engineering. Current standard techniques for evaluating engineered tissues, including histology, biochemical assays and mechanical testing, are destructive approaches. Ultrasound is emerging as a valuable tool for imaging and quantitatively monitoring the properties of engineered tissues and biomaterials longitudinally during fabrication and post-implantation. Ultrasound techniques are rapid, non-invasive, non-destructive and can be easily integrated into sterile environments necessary for tissue engineering. Furthermore, high-frequency quantitative ultrasound techniques can enable volumetric characterization of the structural, biological, and mechanical properties of engineered tissues during fabrication and post-implantation. This review provides an overview of ultrasound imaging, quantitative ultrasound techniques, and elastography, with representative examples of applications of these ultrasound-based techniques to the field of tissue engineering. PMID:26581347
Can contrast-enhanced ultrasonography improve Zone III REBOA placement for prehospital care?
Chaudery, Muzzafer; Clark, James; Morrison, Jonathan J; Wilson, Mark H; Bew, Duncan; Darzi, Ara
2016-01-01
Torso hemorrhage is the primary cause of potentially preventable mortality in trauma. Resuscitative endovascular balloon occlusion of the aorta (REBOA) has been advocated as an adjunct to bridge patients to definitive hemorrhage control. The primary aim of this study was to assess whether contrast-enhanced ultrasonography can improve the accuracy of REBOA placement in the infrarenal aorta (Zone III). A fluoroscopy-free "enhanced" Zone III REBOA technique was developed using a porcine cadaver model. A "standard" over-the-wire Seldinger technique was used, which was enhanced with the addition of a microbubble contrast medium to inflate the balloon, observed with ultrasonography. Following this, attending- and resident-level physicians were randomized into two groups. They were taught either the enhanced with ultrasonography guidance (Group A) or the standard measuring length of catheter insertion (Group B) technique as part of a human cadaver trauma skills course. Outcomes assessed included time (seconds) from insertion to inflation, accuracy, and missed targets. All results were benchmarked against three endovascular experts. There were 20 participants who performed REBOA with Group A (51 [31]) being significantly faster than Group B (90 [63]) (p = 0.003) and more accurate (p = 0.023) with no missed targets. Group B had five missed targets, the most common error being inflation within Zone II. For Zone III REBOA, contrast-enhanced ultrasonography technique is faster and more accurate than the standard technique. This may have value in time-critical and austere environments. Clinical studies are now required to evaluate this approach further.
Li, Hongyi; Shi, Zhou; Sha, Jinming; Cheng, Jieliang
2006-08-01
In the present study, vegetation, soil brightness, and moisture indices were extracted from Landsat ETM remote sensing image, heat indices were extracted from MODIS land surface temperature product, and climate index and other auxiliary geographical information were selected as the input of neural network. The remote sensing eco-environmental background value of standard interest region evaluated in situ was selected as the output of neural network, and the back propagation (BP) neural network prediction model containing three layers was designed. The network was trained, and the remote sensing eco-environmental background value of Fuzhou in China was predicted by using software MATLAB. The class mapping of remote sensing eco-environmental background values based on evaluation standard showed that the total classification accuracy was 87. 8%. The method with a scheme of prediction first and classification then could provide acceptable results in accord with the regional eco-environment types.
Chatake, Toshiyuki; Fujiwara, Satoru
2016-01-01
A difference in the neutron scattering length between hydrogen and deuterium leads to a high density contrast in neutron Fourier maps. In this study, a technique for determining the deuterium/hydrogen (D/H) contrast map in neutron macromolecular crystallography is developed and evaluated using ribonuclease A. The contrast map between the D2O-solvent and H2O-solvent crystals is calculated in real space, rather than in reciprocal space as performed in previous neutron D/H contrast crystallography. The present technique can thus utilize all of the amplitudes of the neutron structure factors for both D2O-solvent and H2O-solvent crystals. The neutron D/H contrast maps clearly demonstrate the powerful detectability of H/D exchange in proteins. In fact, alternative protonation states and alternative conformations of hydroxyl groups are observed at medium resolution (1.8 Å). Moreover, water molecules can be categorized into three types according to their tendency towards rotational disorder. These results directly indicate improvement in the neutron crystal structure analysis. This technique is suitable for incorporation into the standard structure-determination process used in neutron protein crystallography; consequently, more precise and efficient determination of the D-atom positions is possible using a combination of this D/H contrast technique and standard neutron structure-determination protocols.
The Germination of Several Tree Species in Plastic Greenhouses
Howard M. Phipps
1969-01-01
The technique of growing tree seedlings in plastic greenhouses is being evaluated for red pine, jack pine, white spruce, and yellow birch at the Chittenden Nursery in northern Lower Michigan. Both a long growing season and a normal-length growing season in plastic greenhouses were compared with standard outdoor nursery beds (control). First-year results showed that...
Evaluation of pulse-oximetry oxygen saturation taken through skin protective covering
James, Jyotsna; Tiwari, Lokesh; Upadhyay, Pramod; Sreenivas, Vishnubhatla; Bhambhani, Vikas; Puliyel, Jacob M
2006-01-01
Background The hard edges of adult finger clip probes of the pulse oximetry oxygen saturation (POOS) monitor can cause skin damage if used for prolonged periods in a neonate. Covering the skin under the probe with Micropore surgical tape or a gauze piece might prevent such injury. The study was done to see if the protective covering would affect the accuracy of the readings. Methods POOS was studied in 50 full-term neonates in the first week of life. After obtaining consent from their parents the neonates had POOS readings taken directly (standard technique) and through the protective covering. Bland-Altman plots were used to compare the new method with the standard technique. A test of repeatability for each method was also performed. Results The Bland-Altman plots suggest that there is no significant loss of accuracy when readings are taken through the protective covering. The mean difference was 0.06 (SD of 1.39) and 0.04 (SD 1.3) with Micropore and gauze respectively compared to the standard method. The mean difference was 0.22 (SD 0.23) on testing repeatability with the standard method. Conclusion Interposing Micropore or gauze does not significantly affect the accuracy of the POOS reading. The difference between the standard method and the new method was less than the difference seen on testing repeatability of the standard method. PMID:16677394
Evaluation of pulse-oximetry oxygen saturation taken through skin protective covering.
James, Jyotsna; Tiwari, Lokesh; Upadhyay, Pramod; Sreenivas, Vishnubhatla; Bhambhani, Vikas; Puliyel, Jacob M
2006-05-06
The hard edges of adult finger clip probes of the pulse oximetry oxygen saturation (POOS) monitor can cause skin damage if used for prolonged periods in a neonate. Covering the skin under the probe with Micropore surgical tape or a gauze piece might prevent such injury. The study was done to see if the protective covering would affect the accuracy of the readings. POOS was studied in 50 full-term neonates in the first week of life. After obtaining consent from their parents the neonates had POOS readings taken directly (standard technique) and through the protective covering. Bland-Altman plots were used to compare the new method with the standard technique. A test of repeatability for each method was also performed. The Bland-Altman plots suggest that there is no significant loss of accuracy when readings are taken through the protective covering. The mean difference was 0.06 (SD of 1.39) and 0.04 (SD 1.3) with Micropore and gauze respectively compared to the standard method. The mean difference was 0.22 (SD 0.23) on testing repeatability with the standard method. Interposing Micropore or gauze does not significantly affect the accuracy of the POOS reading. The difference between the standard method and the new method was less than the difference seen on testing repeatability of the standard method.
One hospital, one appendectomy: The cost effectiveness of a standardized doctor's preference card.
Skarda, David E; Rollins, Michael; Andrews, Seth; McFadden, Molly; Barnhart, Doug; Meyers, Rebecka; Scaife, Eric
2015-06-01
Appendicitis in children provides a unique opportunity to explore changes that reduce variation, reduce cost, and improve value. In this study we sought to evaluate the effectiveness of standardization of surgical technique and intraoperative disposable device utilization for laparoscopic appendectomy among all surgeons at a tertiary children's hospital. All 6 surgeons at our tertiary children's hospital agreed to standardize to a single technique of performing a laparoscopic appendectomy. We collected data on all pediatric patients who had a laparoscopic appendectomy following implementation of the uniform doctor's preference card (DPC) (March 1, 2013 to February 28, 2014) and compared them to a historical control group. Implementation of the uniform DPC decreased the device cost per appendectomy from $844.11 to $305.32. Operative times (skin incision to skin closure) were 34.8 minutes prior to the uniform DPC and 37.0 minutes using the uniform DPC. There were no significant differences in postappendectomy outcomes. We have demonstrated that implementation of a uniform DPC and technical standardization for laparoscopic appendectomy can significantly reduce cost. Furthermore, this can occur without dramatically increasing operative times, length of stay, or postoperative complications. Copyright © 2015 Elsevier Inc. All rights reserved.
Neuroimaging techniques for memory detection: scientific, ethical, and legal issues.
Meegan, Daniel V
2008-01-01
There is considerable interest in the use of neuroimaging techniques for forensic purposes. Memory detection techniques, including the well-publicized Brain Fingerprinting technique (Brain Fingerprinting Laboratories, Inc., Seattle WA), exploit the fact that the brain responds differently to sensory stimuli to which it has been exposed before. When a stimulus is specifically associated with a crime, the resulting brain activity should differentiate between someone who was present at the crime and someone who was not. This article reviews the scientific literature on three such techniques: priming, old/new, and P300 effects. The forensic potential of these techniques is evaluated based on four criteria: specificity, automaticity, encoding flexibility, and longevity. This article concludes that none of the techniques are devoid of forensic potential, although much research is yet to be done. Ethical issues, including rights to privacy and against self-incrimination, are discussed. A discussion of legal issues concludes that current memory detection techniques do not yet meet United States standards of legal admissibility.
Commowick, Olivier; Akhondi-Asl, Alireza; Warfield, Simon K.
2012-01-01
We present a new algorithm, called local MAP STAPLE, to estimate from a set of multi-label segmentations both a reference standard segmentation and spatially varying performance parameters. It is based on a sliding window technique to estimate the segmentation and the segmentation performance parameters for each input segmentation. In order to allow for optimal fusion from the small amount of data in each local region, and to account for the possibility of labels not being observed in a local region of some (or all) input segmentations, we introduce prior probabilities for the local performance parameters through a new Maximum A Posteriori formulation of STAPLE. Further, we propose an expression to compute confidence intervals in the estimated local performance parameters. We carried out several experiments with local MAP STAPLE to characterize its performance and value for local segmentation evaluation. First, with simulated segmentations with known reference standard segmentation and spatially varying performance, we show that local MAP STAPLE performs better than both STAPLE and majority voting. Then we present evaluations with data sets from clinical applications. These experiments demonstrate that spatial adaptivity in segmentation performance is an important property to capture. We compared the local MAP STAPLE segmentations to STAPLE, and to previously published fusion techniques and demonstrate the superiority of local MAP STAPLE over other state-of-the- art algorithms. PMID:22562727
NASA Astrophysics Data System (ADS)
Ding, Xiang; Li, Fei; Zhang, Jiyan; Liu, Wenli
2016-10-01
Raman spectrometers are usually calibrated periodically to ensure their measurement accuracy of Raman shift. A combination of a piece of monocrystalline silicon chip and a low pressure discharge lamp is proposed as a candidate for the reference standard of Raman shift. A high precision calibration technique is developed to accurately determine the standard value of the silicon's Raman shift around 520cm-1. The technique is described and illustrated by measuring a piece of silicon chip against three atomic spectral lines of a neon lamp. A commercial Raman spectrometer is employed and its error characteristics of Raman shift are investigated. Error sources are evaluated based on theoretical analysis and experiments, including the sample factor, the instrumental factor, the laser factor and random factors. Experimental results show that the expanded uncertainty of the silicon's Raman shift around 520cm-1 can acheive 0.3 cm-1 (k=2), which is more accurate than most of currently used reference materials. The results are validated by comparison measurement between three Raman spectrometers. It is proved that the technique can remarkably enhance the accuracy of Raman shift, making it possible to use the silicon and the lamp to calibrate Raman spectrometers.
Towards efficient backward-in-time adjoint computations using data compression techniques
Cyr, E. C.; Shadid, J. N.; Wildey, T.
2014-12-16
In the context of a posteriori error estimation for nonlinear time-dependent partial differential equations, the state-of-the-practice is to use adjoint approaches which require the solution of a backward-in-time problem defined by a linearization of the forward problem. One of the major obstacles in the practical application of these approaches, we found, is the need to store, or recompute, the forward solution to define the adjoint problem and to evaluate the error representation. Our study considers the use of data compression techniques to approximate forward solutions employed in the backward-in-time integration. The development derives an error representation that accounts for themore » difference between the standard-approach and the compressed approximation of the forward solution. This representation is algorithmically similar to the standard representation and only requires the computation of the quantity of interest for the forward solution and the data-compressed reconstructed solution (i.e. scalar quantities that can be evaluated as the forward problem is integrated). This approach is then compared with existing techniques, such as checkpointing and time-averaged adjoints. Lastly, we provide numerical results indicating the potential efficiency of our approach on a transient diffusion–reaction equation and on the Navier–Stokes equations. These results demonstrate memory compression ratios up to 450×450× while maintaining reasonable accuracy in the error-estimates.« less
Spelleken, E; Crowe, S B; Sutherland, B; Challens, C; Kairn, T
2018-03-01
Gafchromic EBT3 film is widely used for patient specific quality assurance of complex treatment plans. Film dosimetry techniques commonly involve the use of transmission scanning to produce TIFF files, which are analysed using a non-linear calibration relationship between the dose and red channel net optical density (netOD). Numerous film calibration techniques featured in the literature have not been independently verified or evaluated. A range of previously published film dosimetry techniques were re-evaluated, to identify whether these methods produce better results than the commonly-used non-linear, netOD method. EBT3 film was irradiated at calibration doses between 0 and 4000 cGy and 25 pieces of film were irradiated at 200 cGy to evaluate uniformity. The film was scanned using two different scanners: The Epson Perfection V800 and the Epson Expression 10000XL. Calibration curves, uncertainty in the fit of the curve, overall uncertainty and uniformity were calculated following the methods described by the different calibration techniques. It was found that protocols based on a conventional film dosimetry technique produced results that were accurate and uniform to within 1%, while some of the unconventional techniques produced much higher uncertainties (> 25% for some techniques). Some of the uncommon methods produced reliable results when irradiated to the standard treatment doses (< 400 cGy), however none could be recommended as an efficient or accurate replacement for a common film analysis technique which uses transmission scanning, red colour channel analysis, netOD and a non-linear calibration curve for measuring doses up to 4000 cGy when using EBT3 film.
Iglesias-Parra, Maria Rosa; García-Guerrero, Alfonso; García-Mayor, Silvia; Kaknani-Uttumchandani, Shakira; León-Campos, Álvaro; Morales-Asencio, José Miguel
2015-07-01
To develop an evaluation system of clinical competencies for the practicum of nursing students based on the Nursing Interventions Classification (NIC). Psychometric validation study: the first two phases addressed definition and content validation, and the third phase consisted of a cross-sectional study for analyzing reliability. The study population was undergraduate nursing students and clinical tutors. Through the Delphi technique, 26 competencies and 91 interventions were isolated. Cronbach's α was 0.96. Factor analysis yielded 18 factors that explained 68.82% of the variance. Overall inter-item correlation was 0.26, and total-item correlation ranged between 0.66 and 0.19. A competency system for the nursing practicum, structured on the NIC, is a reliable method for assessing and evaluating clinical competencies. Further evaluations in other contexts are needed. The availability of standardized language systems in the nursing discipline supposes an ideal framework to develop the nursing curricula. © 2015 Sigma Theta Tau International.
Imaging evaluation of non-alcoholic fatty liver disease: focused on quantification.
Lee, Dong Ho
2017-12-01
Non-alcoholic fatty liver disease (NAFLD) has been an emerging major health problem, and the most common cause of chronic liver disease in Western countries. Traditionally, liver biopsy has been gold standard method for quantification of hepatic steatosis. However, its invasive nature with potential complication as well as measurement variability are major problem. Thus, various imaging studies have been used for evaluation of hepatic steatosis. Ultrasonography provides fairly good accuracy to detect moderate-to-severe degree hepatic steatosis, but limited accuracy for mild steatosis. Operator-dependency and subjective/qualitative nature of examination are another major drawbacks of ultrasonography. Computed tomography can be considered as an unsuitable imaging modality for evaluation of NAFLD due to potential risk of radiation exposure and limited accuracy in detecting mild steatosis. Both magnetic resonance spectroscopy and magnetic resonance imaging using chemical shift technique provide highly accurate and reproducible diagnostic performance for evaluating NAFLD, and therefore, have been used in many clinical trials as a non-invasive reference of standard method.
Imaging evaluation of non-alcoholic fatty liver disease: focused on quantification
2017-01-01
Non-alcoholic fatty liver disease (NAFLD) has been an emerging major health problem, and the most common cause of chronic liver disease in Western countries. Traditionally, liver biopsy has been gold standard method for quantification of hepatic steatosis. However, its invasive nature with potential complication as well as measurement variability are major problem. Thus, various imaging studies have been used for evaluation of hepatic steatosis. Ultrasonography provides fairly good accuracy to detect moderate-to-severe degree hepatic steatosis, but limited accuracy for mild steatosis. Operator-dependency and subjective/qualitative nature of examination are another major drawbacks of ultrasonography. Computed tomography can be considered as an unsuitable imaging modality for evaluation of NAFLD due to potential risk of radiation exposure and limited accuracy in detecting mild steatosis. Both magnetic resonance spectroscopy and magnetic resonance imaging using chemical shift technique provide highly accurate and reproducible diagnostic performance for evaluating NAFLD, and therefore, have been used in many clinical trials as a non-invasive reference of standard method. PMID:28994271
DOE Office of Scientific and Technical Information (OSTI.GOV)
Massabeau, Carole, E-mail: cmassabeau@hotmail.com; Fournier-Bidoz, Nathalie; Wakil, Georges
2012-01-01
To evaluate the benefits and limitations of helical tomotherapy (HT) for loco-regional irradiation of patients after a mastectomy and immediate implant-based reconstruction. Ten breast cancer patients with retropectoral implants were randomly selected for this comparative study. Planning target volumes (PTVs) 1 (the volume between the skin and the implant, plus margin) and 2 (supraclavicular, infraclavicular, and internal mammary nodes, plus margin) were 50 Gy in 25 fractions using a standard technique and HT. The extracted dosimetric data were compared using a 2-tailed Wilcoxon matched-pair signed-rank test. Doses for PTV1 and PTV2 were significantly higher with HT (V95 of 98.91 andmore » 97.91%, respectively) compared with the standard technique (77.46 and 72.91%, respectively). Similarly, the indexes of homogeneity were significantly greater with HT (p = 0.002). HT reduced ipsilateral lung volume that received {>=}20 Gy (16.7 vs. 35%), and bilateral lungs (p = 0.01) and neighboring organs received doses that remained well below tolerance levels. The heart volume, which received 25 Gy, was negligible with both techniques. HT can achieve full target coverage while decreasing high doses to the heart and ipsilateral lung. However, the low doses to normal tissue volumes need to be reduced in future studies.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arbique, G; Anderson, J; Guild, J
Purpose: The National Lung Screening Trial mandated manual low dose CT technique factors, where up to a doubling of radiation output could be used over a regular to large patient size range. Recent guidance from the AAPM and ACR for lung cancer CT screening recommends radiation output adjustment for patient size either through AEC or a manual technique chart. This study evaluated the use of AEC for output control and dose reduction. Methods: The study was performed on a multidetector helical CT scanner (Aquillion ONE, Toshiba Medical) equipped with iterative reconstruction (ADIR-3D), AEC was adjusted with a standard deviation (SD)more » image quality noise index. The protocol SD parameter was incrementally increased to reduce patient population dose while image quality was evaluated by radiologist readers scoring the clinical utility of images on a Likert scale. Results: Plots of effective dose vs. body size (water cylinder diameter reported by the scanner) demonstrate monotonic increase in patient dose with increasing patient size. At the initial SD setting of 19 the average CTDIvol for a standard size patient was ∼ 2.0 mGy (1.2 mSv effective dose). This was reduced to ∼1.0 mGy (0.5 mSv) at an SD of 25 with no noticeable reduction in clinical utility of images as demonstrated by Likert scoring. Plots of effective patient diameter and BMI vs body size indicate that these metrics could also be used for manual technique charts. Conclusion: AEC offered consistent and reliable control of radiation output in this study. Dose for a standard size patient was reduced to one-third of the 3 mGy CTDIvol limit required for ACR accreditation of lung cancer CT screening. Gary Arbique: Research Grant, Toshiba America Medical Systems; Cecelia Brewington: Research Grant, Toshiba America Medical Systems; Di Zhang: Employee, Toshiba America Medical Systems.« less
NASA Astrophysics Data System (ADS)
Wang, Tian; Cui, Xiaoxin; Ni, Yewen; Liao, Kai; Liao, Nan; Yu, Dunshan; Cui, Xiaole
2017-04-01
With shrinking transistor feature size, the fin-type field-effect transistor (FinFET) has become the most promising option in low-power circuit design due to its superior capability to suppress leakage. To support the VLSI digital system flow based on logic synthesis, we have designed an optimized high-performance low-power FinFET standard cell library based on employing the mixed FBB/RBB technique in the existing stacked structure of each cell. This paper presents the reliability evaluation of the optimized cells under process and operating environment variations based on Monte Carlo analysis. The variations are modelled with Gaussian distribution of the device parameters and 10000 sweeps are conducted in the simulation to obtain the statistical properties of the worst-case delay and input-dependent leakage for each cell. For comparison, a set of non-optimal cells that adopt the same topology without employing the mixed biasing technique is also generated. Experimental results show that the optimized cells achieve standard deviation reduction of 39.1% and 30.7% at most in worst-case delay and input-dependent leakage respectively while the normalized deviation shrinking in worst-case delay and input-dependent leakage can be up to 98.37% and 24.13%, respectively, which demonstrates that our optimized cells are less sensitive to variability and exhibit more reliability. Project supported by the National Natural Science Foundation of China (No. 61306040), the State Key Development Program for Basic Research of China (No. 2015CB057201), the Beijing Natural Science Foundation (No. 4152020), and Natural Science Foundation of Guangdong Province, China (No. 2015A030313147).
Magnetic resonance imaging of articular cartilage: trauma, degeneration, and repair.
Potter, Hollis G; Foo, Li F
2006-04-01
The assessment of articular cartilage using magnetic resonance imaging has seen considerable advances in recent years. Cartilage morphologic characteristics can now be evaluated with a high degree of accuracy and reproducibility using dedicated pulse sequences, which are becoming standard at many institutions. These techniques detect clinically unsuspected traumatic cartilage lesions, allowing the physician to study their natural history with longitudinal evaluation and also to assess disease status in degenerative osteoarthritis. Magnetic resonance imaging also provides a more objective assessment of cartilage repair to augment the information obtained from more subjective clinical outcome instruments. Newly developed methods that provide detail at an ultrastructural level offer an important addition to cartilage evaluation, particularly in the detection of early alterations in the extracellular matrix. These methods have created an undeniably important role for magnetic resonance imaging in the reproducible, noninvasive, and objective evaluation and monitoring of cartilage. An overview of the advances, current techniques, and impact of magnetic resonance imaging in the setting of trauma, degenerative arthritides, and surgical treatment for cartilage injury is presented.
Zhuang, Yan; Xie, Bangtie; Weng, Shengxin; Xie, Yanming
2011-10-01
To construct real world integrated data warehouse on re-evaluation of post-marketing traditional Chinese medicine for the research on key techniques of clinic re-evaluation which mainly includes indication of traditional Chinese medicine, dosage usage, course of treatment, unit medication, combined disease and adverse reaction, which provides data for reviewed research on its safety,availability and economy,and provides foundation for perspective research. The integrated data warehouse extracts and integrate data from HIS by information collection system and data warehouse technique and forms standard structure and data. The further research is on process based on the data. A data warehouse and several sub data warehouses were built, which focused on patients' main records, doctor orders, diseases diagnoses, laboratory results and economic indications in hospital. These data warehouses can provide research data for re-evaluation of post-marketing traditional Chinese medicine, and it has clinical value. Besides, it points out the direction for further research.
NASA Astrophysics Data System (ADS)
Medjoubi, K.; Dawiec, A.
2017-12-01
A simple method is proposed in this work for quantitative evaluation of the quality of the threshold adjustment and the flat-field correction of Hybrid Photon Counting pixel (HPC) detectors. This approach is based on the Photon Transfer Curve (PTC) corresponding to the measurement of the standard deviation of the signal in flat field images. Fixed pattern noise (FPN), easily identifiable in the curve, is linked to the residual threshold dispersion, sensor inhomogeneity and the remnant errors in flat fielding techniques. The analytical expression of the signal to noise ratio curve is developed for HPC and successfully used as a fit function applied to experimental data obtained with the XPAD detector. The quantitative evaluation of the FPN, described by the photon response non-uniformity (PRNU), is measured for different configurations (threshold adjustment method and flat fielding technique) and is demonstrated to be used in order to evaluate the best setting for having the best image quality from a commercial or a R&D detector.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hansen, Anders T., E-mail: andehans@rm.dk; Lukacova, Slavka; Lassen-Ramshad, Yasmin
2015-01-01
When standard conformal x-ray technique for craniospinal irradiation is used, it is a challenge to achieve satisfactory dose coverage of the target including the area of the cribriform plate, while sparing organs at risk. We present a new intensity-modulated radiation therapy (IMRT), noncoplanar technique, for delivering irradiation to the cranial part and compare it with 3 other techniques and previously published results. A total of 13 patients who had previously received craniospinal irradiation with standard conformal x-ray technique were reviewed. New treatment plans were generated for each patient using the noncoplanar IMRT-based technique, a coplanar IMRT-based technique, and a coplanarmore » volumetric-modulated arch therapy (VMAT) technique. Dosimetry data for all patients were compared with the corresponding data from the conventional treatment plans. The new noncoplanar IMRT technique substantially reduced the mean dose to organs at risk compared with the standard radiation technique. The 2 other coplanar techniques also reduced the mean dose to some of the critical organs. However, this reduction was not as substantial as the reduction obtained by the noncoplanar technique. Furthermore, compared with the standard technique, the IMRT techniques reduced the total calculated radiation dose that was delivered to the normal tissue, whereas the VMAT technique increased this dose. Additionally, the coverage of the target was significantly improved by the noncoplanar IMRT technique. Compared with the standard technique, the coplanar IMRT and the VMAT technique did not improve the coverage of the target significantly. All the new planning techniques increased the number of monitor units (MU) used—the noncoplanar IMRT technique by 99%, the coplanar IMRT technique by 122%, and the VMAT technique by 26%—causing concern for leak radiation. The noncoplanar IMRT technique covered the target better and decreased doses to organs at risk compared with the other techniques. All the new techniques increased the number of MU compared with the standard technique.« less
Thanopoulos, Basil Vasilios D; Ninios, Vlassis; Dardas, Petros; Giannopoulos, Andreas; Deleanou, Dan; Iancovici, Silvia
2016-11-15
The standard technique of catheter closure of patent ductus arteriosus (PDA) may be associated with arterial complications particularly in small pediatric patients. The aim of this study was to evaluate whether catheter closure of PDA in small children using an exclusive venous approach is a safe and effective alternative to closure with the standard technique. One hundred-twelve patients, aged 2 to 24 months, were randomly assigned in a 1:1 ratio to catheter closure of PDA using the standard technique (group 1) and an exclusive venous approach (group 2), respectively. In group 2, the procedure was guided using hand injections of contrast media through the delivery sheath and 2-dimensional and color Doppler echocardiography. Group 1: the PDA diameter ranged from 2 to 5.5 mm and the device diameter ranged from 4 to 8 mm. The PDA occluders were permanently implanted in all patients. Five losses of the arterial pulses that were restored with intravenous infusion of heparin and recombinant tissue plasminogen activator (rtPA), and 4 groin hematomas were the main complications of the procedure. Group 2: the mean PDA diameter ranged from 2.5 to 6 mm and the device diameter ranged from 3 to 8 mm. The PDA occluders were permanently implanted in all but 2 patients. There were no complications. Complete echocardiographic closure of PDA at 1-month follow-up was observed in all 110 patients. Exclusive transvenous PDA occlusion is an effective and safe technique that prevents the arterial complications of the standard approach in small children. Copyright © 2016 Elsevier Inc. All rights reserved.
Evaluation of Two Protocols to Measure the Accuracy of Fixed Dental Prostheses: An In Vitro Study.
Schönberger, Joana; Erdelt, Kurt-Jürgen; Bäumer, Daniel; Beuer, Florian
2017-02-02
The aim of this in vitro study was to compare two measurement protocols of the internal and marginal fit of three-unit zirconia fixed dental prostheses (FDPs). Forty-four FDPs were fabricated for standardized dies by two laboratory CAD/CAM systems: Cercon (n = 22) and Ceramill (n = 22). The fitting was tested using a replica technique (RT = technique 1) with a light-body silicone stabilized with heavy-body material. After producing the replicas, cross-sections were made in the buccolingual and mesiodistal directions. FDPs were cemented on definitive dies, embedded, and sectioned (CST = technique 2). The marginal and internal fits were measured under an optical microscope at 50x magnification with a special software program. Data evaluation was performed according to prior studies at a level of significance of 5%. The mean internal gap width was 51 ± 36 μm for the RT and 52 ± 35 μm for the cross-section technique (CST) (p = 0.74). The mean marginal gap width was 27 ± 18 μm for RT and 30 ± 19 μm for CST (p = 0.19). Statistical tests showed no significant differences (p > 0.05). Both techniques can be used for fit evaluation; however, the noninvasive RT is suitable for clinical use. © 2017 by the American College of Prosthodontists.
Design and evaluation of a nondestructive fissile assay device for HTGR fuel samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
McNeany, S. R.; Knoll, R. W.; Jenkins, J. D.
1979-02-01
Nondestructive assay of fissile material plays an important role in nuclear fuel processing facilities. Information for product quality control, plant criticality safety, and nuclear materials accountability can be obtained from assay devices. All of this is necessary for a safe, efficient, and orderly operation of a production plant. Presented here is a design description and an operational evaluation of a device developed to nondestructively assay small samples of High-Temperature Gas-Cooled Reactor (HTGR) fuel. The measurement technique employed consists in thermal-neutron irradiation of a sample followed by pneumatic transfer to a high-efficiency neutron detector where delayed neutrons are counted. In general,more » samples undergo several irradiation and count cycles during a measurement. The total number of delayed-neutron counts accumulated is translated into grams of fissile mass through comparison with the counts accumulated in an identical irradiation and count sequence of calibration standards. Successful operation of the device through many experiments over a one-year period indicates high operational reliability. Tests of assay precision show this to be better than 0.25% for measurements of 10 min. Assay biases may be encountered if calibration standards are not representative of unknown samples, but reasonable care in construction and control of standards should lead to no more than 0.2% bias in the measurements. Nondestructive fissile assay of HTGR fuel samples by thermal-neutron irradiation and delayed-neutron detection has been demonstrated to be a rapid and accurate analysis technique. However, careful attention and control must be given to calibration standards to see that they remain representative of unknown samples.« less
An intercomparison of aircraft instrumentation for tropospheric measurements of sulfur dioxide
NASA Technical Reports Server (NTRS)
Gregory, Gerald L.; Davis, Douglas D.; Beltz, Nobert; Bandy, Alan R.; Ferek, Ronald J.; Thornton, Donald C.
1993-01-01
As part of the NASA Tropospheric Chemistry Program, a series of field intercomparisons have been conducted to evaluate the state-of-the art for measuring key tropospheric species. One of the objectives of the third intercomparison campaign in this series, Chemical Instrumentation Test and Evaluation 3 (CITE 3), was to evaluate instrumentation for making reliable tropospheric aircraft measurements of sulfur dioxide, dimethyl sulfide, hydrogen sulfide, carbon disulfide, and carbonyl sulfide. This paper reports the results of the intercomparisons of five sulfur dioxide measurement methods ranging from filter techniques, in which samples collected in flight are returned to the laboratory for analyses (chemiluminescent or ion chromatographic), to near real-time, in-flight measurements via gas chromatographic, mass spectrometric, and chemiluminescent techniques. All techniques showed some tendency to track sizeable changes in ambient SO2 such as those associated with altitude changes. For SO2 mixing ratios in the range of 200 pptv to a few ppbv, agreement among the techniques varies from about 30% to several orders of magnitude, depending upon the pair of measurements intercompared. For SO2 mixing ratios less than 200 pptv, measurements from the techniques are uncorrelated. In general, observed differences in the measurement of standards do not account for the flight results. The CITE 3 results do not unambiguously identify one or more of the measurement techniques as providing valid or invalid SO2 measurements, but identify the range of 'potential' uncertainty in SO2 measurements reported by currently available instrumentation and as measured under realistic aircraft environments.
Baker, Jay B; Maskell, Kevin F; Matlock, Aaron G; Walsh, Ryan M; Skinner, Carl G
2015-07-01
We compared intubating with a preloaded bougie (PB) against standard bougie technique in terms of success rates, time to successful intubation and provider preference on a cadaveric airway model. In this prospective, crossover study, healthcare providers intubated a cadaver using the PB technique and the standard bougie technique. Participants were randomly assigned to start with either technique. Following standardized training and practice, procedural success and time for each technique was recorded for each participant. Subsequently, participants were asked to rate their perceived ease of intubation on a visual analogue scale of 1 to 10 (1=difficult and 10=easy) and to select which technique they preferred. 47 participants with variable experience intubating were enrolled at an emergency medicine intern airway course. The success rate of all groups for both techniques was equal (95.7%). The range of times to completion for the standard bougie technique was 16.0-70.2 seconds, with a mean time of 29.7 seconds. The range of times to completion for the PB technique was 15.7-110.9 seconds, with a mean time of 29.4 seconds. There was a non-significant difference of 0.3 seconds (95% confidence interval -2.8 to 3.4 seconds) between the two techniques. Participants rated the relative ease of intubation as 7.3/10 for the standard technique and 7.6/10 for the preloaded technique (p=0.53, 95% confidence interval of the difference -0.97 to 0.50). Thirty of 47 participants subjectively preferred the PB technique (p=0.039). There was no significant difference in success or time to intubation between standard bougie and PB techniques. The majority of participants in this study preferred the PB technique. Until a clear and clinically significant difference is found between these techniques, emergency airway operators should feel confident in using the technique with which they are most comfortable.
NASA Astrophysics Data System (ADS)
Miller, C. J.; Yoder, T. S.
2010-06-01
Explosive trace detection equipment has been deployed to airports for more than a decade. During this time, the need for standardized procedures and calibrated trace amounts for ensuring that the systems are operating properly and detecting the correct explosive has been apparent but a standard representative of a fingerprint has been elusive. Standards are also necessary to evaluate instrumentation in the laboratories during development and prior to deployment to determine sample throughput, probability of detection, false positive/negative rates, ease of use by operator, mechanical and/or software problems that may be encountered, and other pertinent parameters that would result in the equipment being unusable during field operations. Since many laboratories do not have access to nor are allowed to handle explosives, the equipment is tested using techniques aimed at simulating the actual explosives fingerprint. This laboratory study focused on examining the similarities and differences in three different surface contamination techniques that are used to performance test explosive trace detection equipment in an attempt to determine how effective the techniques are at replicating actual field samples and to offer scenarios where each contamination technique is applicable. The three techniques used were dry transfer deposition of standard solutions using the Transportation Security Laboratory’s (TSL) patented dry transfer techniques (US patent 6470730), direct deposition of explosive standards onto substrates, and fingerprinting of actual explosives onto substrates. RDX was deposited on the surface of one of five substrates using one of the three different deposition techniques. The process was repeated for each substrate type using each contamination technique. The substrate types used were: 50% cotton/50% polyester as found in T-shirts, 100% cotton with a smooth surface such as that found in a cotton dress shirt, 100% cotton on a rough surface such as that found on canvas or denim, suede leather such as might be found on jackets, purses, or shoes, and painted metal obtained from a car hood at a junk yard. The samples were not pre-cleaned prior to testing and contained sizing agents, and in the case of the metal, oil and dirt. The substrates were photographed using a Zeiss Discover V12 stereoscope with Axiocam ICc1 3 megapixel digital camera to determine the difference in the crystalline structure and surface contamination in an attempt to determine differences and similarities associated with current contamination deposition techniques. Some samples were analyzed using scanning electron microscopy (SEM) and some were extracted and analyzed with high performance liquid chromatography (HPLC) or gas chromatography with an electron capture detector (GC-ECD) to quantify the data.
Connatser, Raynella M.; Lewis, Sr., Samuel Arthur; Keiser, James R.; ...
2014-10-03
Integrating biofuels with conventional petroleum products requires improvements in processing to increase blendability with existing fuels. This work demonstrates analysis techniques for more hydrophilic bio-oil liquids that give improved quantitative and qualitative description of the total acid content and organic acid profiles. To protect infrastructure from damage and reduce the cost associated with upgrading, accurate determination of acid content and representative chemical compound analysis are central imperatives to assessing both the corrosivity and the progress toward removing oxygen and acidity in processed biomass liquids. Established techniques form an ample basis for bio-liquids evaluation. However, early in the upgrading process, themore » unique physical phases and varied hydrophilicity of many pyrolysis liquids can render analytical methods originally designed for use in petroleum-derived oils inadequate. In this work, the water solubility of the organic acids present in bio-oils is exploited in a novel extraction and titration technique followed by analysis on the water-based capillary electrophoresis (CE) platform. The modification of ASTM D664, the standard for Total Acid Number (TAN), to include aqueous carrier solvents improves the utility of that approach for quantifying acid content in hydrophilic bio-oils. Termed AMTAN (modified Total Acid Number), this technique offers 1.2% relative standard deviation and dynamic range comparable to the conventional ASTM method. Furthermore, the results of corrosion product evaluations using several different sources of real bio-oil are discussed in the context of the unique AMTAN and CE analytical approaches developed to facilitate those measurements.« less
Hyperspectral face recognition with spatiospectral information fusion and PLS regression.
Uzair, Muhammad; Mahmood, Arif; Mian, Ajmal
2015-03-01
Hyperspectral imaging offers new opportunities for face recognition via improved discrimination along the spectral dimension. However, it poses new challenges, including low signal-to-noise ratio, interband misalignment, and high data dimensionality. Due to these challenges, the literature on hyperspectral face recognition is not only sparse but is limited to ad hoc dimensionality reduction techniques and lacks comprehensive evaluation. We propose a hyperspectral face recognition algorithm using a spatiospectral covariance for band fusion and partial least square regression for classification. Moreover, we extend 13 existing face recognition techniques, for the first time, to perform hyperspectral face recognition.We formulate hyperspectral face recognition as an image-set classification problem and evaluate the performance of seven state-of-the-art image-set classification techniques. We also test six state-of-the-art grayscale and RGB (color) face recognition algorithms after applying fusion techniques on hyperspectral images. Comparison with the 13 extended and five existing hyperspectral face recognition techniques on three standard data sets show that the proposed algorithm outperforms all by a significant margin. Finally, we perform band selection experiments to find the most discriminative bands in the visible and near infrared response spectrum.
MRI to assess renal structure and function.
Artunc, Ferruh; Rossi, Cristina; Boss, Andreas
2011-11-01
In addition to excellent anatomical depiction, MRI techniques have expanded to study functional aspects of renal physiology, such as renal perfusion, glomerular filtration rate (GFR) or tissue oxygenation. This review will focus on current developments with an emphasis on clinical applicability. The method of GFR determination is largely heterogeneous and still has weaknesses. However, the technique of employing liver disappearance curves has been shown to be accurate in healthy persons and patients with chronic kidney disease. In potential kidney donors, complete evaluation of kidney anatomy and function can be accomplished in a single-stop investigation. Techniques without contrast media can be utilized to measure renal tissue oxygenation (blood oxygen level-dependent MRI) or perfusion (arterial spin labeling) and could aid in the diagnosis and treatment of ischemic renal diseases, such as renal artery stenosis. Diffusion imaging techniques may provide information on spatially restricted water diffusion and tumor cellularity. Functional MRI opens new horizons in studying renal physiology and pathophysiology in vivo. Although extensively utilized in research, labor-intensive postprocessing and lack of standardization currently limit the clinical applicability of functional MRI. Further studies are necessary to evaluate the clinical value of functional magnetic resonance techniques for early discovery and characterization of kidney disease.
Advanced analysis techniques for uranium assay
DOE Office of Scientific and Technical Information (OSTI.GOV)
Geist, W. H.; Ensslin, Norbert; Carrillo, L. A.
2001-01-01
Uranium has a negligible passive neutron emission rate making its assay practicable only with an active interrogation method. The active interrogation uses external neutron sources to induce fission events in the uranium in order to determine the mass. This technique requires careful calibration with standards that are representative of the items to be assayed. The samples to be measured are not always well represented by the available standards which often leads to large biases. A technique of active multiplicity counting is being developed to reduce some of these assay difficulties. Active multiplicity counting uses the measured doubles and triples countmore » rates to determine the neutron multiplication (f4) and the product of the source-sample coupling ( C ) and the 235U mass (m). Since the 35U mass always appears in the multiplicity equations as the product of Cm, the coupling needs to be determined before the mass can be known. A relationship has been developed that relates the coupling to the neutron multiplication. The relationship is based on both an analytical derivation and also on empirical observations. To determine a scaling constant present in this relationship, known standards must be used. Evaluation of experimental data revealed an improvement over the traditional calibration curve analysis method of fitting the doubles count rate to the 235Um ass. Active multiplicity assay appears to relax the requirement that the calibration standards and unknown items have the same chemical form and geometry.« less
Shenoy-Bhangle, Anuradha S; Nimkin, Katherine; Aranson, Thomas; Gee, Michael S
2016-01-01
MR enterography is increasingly utilized for noninvasive evaluation of disease activity in young patients with Crohn disease and has great impact on clinical management. Diffusion-weighted imaging (DWI) is a rapid MR imaging technique that measures molecular diffusion of water and is sensitive to the inflammatory process; however, its value to MR enterography has not been rigorously evaluated. To determine whether the addition of DWI to MR enterography is helpful in evaluating Crohn disease activity in young patients when compared to a histological reference. In this single-institution retrospective study, we searched an imaging database for the period January 2010 to December 2012 to identify patients age 19 years and younger who had MR enterography with diffusion-weighted imaging (DWI). We used an electronic medical record search to identify those who had MR enterography and colonoscopy performed within 28 days of each other. All MR enterography scans were performed on a 1.5-T or 3-T clinical MR scanner with phased-array torso coil configuration using standard pulse sequences as well as axial DWI with b values of 50, 400 and 800. Bowel segments were evaluated for disease activity based on standard MR enterography sequences; in addition, segmental apparent diffusion coefficient (ADC) values were calculated based on DWI. Histological reference for disease activity was based on assessment for mucosal inflammatory changes on endoscopic biopsy. MR enterography and DWI evaluation were performed in a blinded fashion with respect to histological results. We included imaging of 78 bowel segments from 27 patients (mean age 14.5 ± 3.02 years) with known Crohn disease in the study. The mean ADC for bowel segments with active disease was 1.56 ± 0.7 × 10(3) mm(2)/s compared with 2.58 ± 1.4 × 10(3) mm(2)/s for segments without active disease, a difference that was statistically significant (P < 0.01, Student's t-test). Using a threshold value of 2.0 × 10(3) mm(2)/s, DWI demonstrated lower accuracy (64.1%) but higher sensitivity (78.8%) for detecting active disease compared with standard MR enterography (69.2% and 54.6%, respectively). Combining DWI with MR enterography, using DWI as the initial screen and MR enterography afterward to reduce false negativity, led to a significant increase in accuracy (76.9%; P = 0.03, McNemar's test) compared with either imaging technique alone. Although DWI does not perform as well as standard MR enterography for detection of active Crohn disease, the combination of DWI and MR enterography increases imaging accuracy for determining disease activity compared with either technique alone. These results indicate that DWI adds value to MR enterography and supports the incorporation of DWI into MR enterography protocols for evaluation of Crohn disease in young patients.
Pullout strength of standard vs. cement-augmented rotator cuff repair anchors in cadaveric bone.
Aziz, Keith T; Shi, Brendan Y; Okafor, Louis C; Smalley, Jeremy; Belkoff, Stephen M; Srikumaran, Uma
2018-05-01
We evaluate a novel method of rotator cuff repair that uses arthroscopic equipment to inject bone cement into placed suture anchors. A cadaver model was used to assess the pullout strength of this technique versus anchors without augmentation. Six fresh-frozen matched pairs of upper extremities were screened to exclude those with prior operative procedures, fractures, or neoplasms. One side from each pair was randomized to undergo standard anchor fixation with the contralateral side to undergo anchor fixation augmented with bone cement. After anchor fixation, specimens were mounted on a servohydraulic testing system and suture anchors were pulled at 90° to the insertion to simulate the anatomic pull of the rotator cuff. Sutures were pulled at 1 mm/s until failure. The mean pullout strength was 540 N (95% confidence interval, 389 to 690 N) for augmented anchors and 202 N (95% confidence interval, 100 to 305 N) for standard anchors. The difference in pullout strength was statistically significant (P < 0.05). This study shows superior pullout strength of a novel augmented rotator cuff anchor technique. The described technique, which is achieved by extruding polymethylmethacrylate cement through a cannulated in situ suture anchor with fenestrations, significantly increased the ultimate failure load in cadaveric human humeri. This novel augmented fixation technique was simple and can be implemented with existing instrumentation. In osteoporotic bone, it may substantially reduce the rate of anchor failure. Copyright © 2018 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Hudoklin, D.; Šetina, J.; Drnovšek, J.
2012-09-01
The measurement of the water-vapor permeation rate (WVPR) through materials is very important in many industrial applications such as the development of new fabrics and construction materials, in the semiconductor industry, packaging, vacuum techniques, etc. The demand for this kind of measurement grows considerably and thus many different methods for measuring the WVPR are developed and standardized within numerous national and international standards. However, comparison of existing methods shows a low level of mutual agreement. The objective of this paper is to demonstrate the necessary uncertainty evaluation for WVPR measurements, so as to provide a basis for development of a corresponding reference measurement standard. This paper presents a specially developed measurement setup, which employs a precision dew-point sensor for WVPR measurements on specimens of different shapes. The paper also presents a physical model, which tries to account for both dynamic and quasi-static methods, the common types of WVPR measurements referred to in standards and scientific publications. An uncertainty evaluation carried out according to the ISO/IEC guide to the expression of uncertainty in measurement (GUM) shows the relative expanded ( k = 2) uncertainty to be 3.0 % for WVPR of 6.71 mg . h-1 (corresponding to permeance of 30.4 mg . m-2. day-1 . hPa-1).
If You're Not Measuring, You're Guessing: The Advent of Objective Concussion Assessments.
Broglio, Steven P; Guskiewicz, Kevin M; Norwig, John
2017-03-01
Sport-related concussion remains one of the most complex injuries presented to sports medicine professionals. Although the injury has been recognized since ancient times, the concussion-assessment process has seen significant advances over the last 30 years. This review outlines the addition of objective measures to the clinical evaluation of the concussed athlete, beginning in the 1980s and continuing through the modern age. International and domestic organizations now describe standardized symptom reports, neurostatus and neurocognitive-function evaluations, and postural-control measures as standards of medical care, a significant shift from a short time ago. Despite this progression, much about the injury remains unknown, including new clinical and research-based assessment techniques and how the injury may influence the athlete's cognitive health over the long term.
Wang, Dunling; Fiessel, Wanda
2008-01-01
This study evaluated three different dehydrated media for simultaneous detection and enumeration of total coliform (TC) and Escherichia coli in drinking water samples with a standard membrane filtration procedure. The experiment indicated that the differential coliform agar (DCA) medium was the most effective among the tested media in enumerating TC and E. coli, without the need for extensive accompanying confirmation tests. The results for DCA medium were highly reproducible for both TC and E. coli with standard deviation of 6.0 and 6.1, respectively. A high agreement (82%) was found between DCA and m-Endo media on 152 drinking water samples in terms of TC positive. The DCA medium also reduced concealment of background bacteria.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Borring, J.; Gundtoft, H.E.; Borum, K.K.
1997-08-01
In an effort to improve their ultrasonic scanning technique for accurate determination of the cladding thickness in LEU fuel plates, new equipment and modifications to the existing hardware and software have been tested and evaluated. The authors are now able to measure an aluminium thickness down to 0.25 mm instead of the previous 0.35 mm. Furthermore, they have shown how the measuring sensitivity can be improved from 0.03 mm to 0.01 mm. It has now become possible to check their standard fuel plates for DR3 against the minimum cladding thickness requirements non-destructively. Such measurements open the possibility for the acceptancemore » of a thinner nominal cladding than normally used today.« less
Nondestructive testing of Scout rocket motors
NASA Technical Reports Server (NTRS)
Oaks, A. E.
1972-01-01
The nondestructive tests applied to Scout rocket motors were reviewed and appraised. Analytical techniques were developed to evaluate the capabilities of the radiographic and ultrasonic procedures used. Major problem areas found were the inadequacy of high voltage radiography for detecting unbonds and propellant cracks having narrow widths, the inability to relate the ultrasonic signals received from flat-bottomed holes in standards to those received from real defects and in the general area of the specification of acceptance criteria and how these were to be met. To counter the deficiencies noted, analyses were conducted to the potential utility of radiometric, acoustic, holographic and thermographic techniques for motor and nozzle bond inspection, a new approach to qualifying magnetic particle inspection and the application of acoustic emission analysis to the evaluation of proof and leak test data.
The dream of a one-stop-shop: Meta-analysis on myocardial perfusion CT.
Pelgrim, Gert Jan; Dorrius, Monique; Xie, Xueqian; den Dekker, Martijn A M; Schoepf, U Joseph; Henzler, Thomas; Oudkerk, Matthijs; Vliegenthart, Rozemarijn
2015-12-01
To determine the diagnostic performance of computed tomography (CT) perfusion techniques for the detection of functionally relevant coronary artery disease (CAD) in comparison to reference standards, including invasive coronary angiography (ICA), single photon emission computed tomography (SPECT), and magnetic resonance imaging (MRI). PubMed, Web of Knowledge and Embase were searched from January 1, 1998 until July 1, 2014. The search yielded 9475 articles. After duplicate removal, 6041 were screened on title and abstract. The resulting 276 articles were independently analyzed in full-text by two reviewers, and included if the inclusion criteria were met. The articles reporting diagnostic parameters including true positive, true negative, false positive and false negative were subsequently evaluated for the meta-analysis. Results were pooled according to CT perfusion technique, namely snapshot techniques: single-phase rest, single-phase stress, single-phase dual-energy stress and combined coronary CT angiography [rest] and single-phase stress, as well the dynamic technique: dynamic stress CT perfusion. Twenty-two articles were included in the meta-analysis (1507 subjects). Pooled per-patient sensitivity and specificity of single-phase rest CT compared to rest SPECT were 89% (95% confidence interval [CI], 82-94%) and 88% (95% CI, 78-94%), respectively. Vessel-based sensitivity and specificity of single-phase stress CT compared to ICA-based >70% stenosis were 82% (95% CI, 64-92%) and 78% (95% CI, 61-89%). Segment-based sensitivity and specificity of single-phase dual-energy stress CT in comparison to stress MRI were 75% (95% CI, 60-85%) and 95% (95% CI, 80-99%). Segment-based sensitivity and specificity of dynamic stress CT perfusion compared to stress SPECT were 77% (95% CI, 67-85) and 89% (95% CI, 78-95%). For combined coronary CT angiography and single-phase stress CT, vessel-based sensitivity and specificity in comparison to ICA-based >50% stenosis were 84% (95% CI, 67-93%) and 93% (95% CI, 89-96%). This meta-analysis shows considerable variation in techniques and reference standards for CT of myocardial blood supply. While CT seems sensitive and specific for evaluation of hemodynamically relevant CAD, studies so far are limited in size. Standardization of myocardial perfusion CT technique is essential. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Ehmann, Andreas F.; Downie, J. Stephen
2005-09-01
The objective of the International Music Information Retrieval Systems Evaluation Laboratory (IMIRSEL) project is the creation of a large, secure corpus of audio and symbolic music data accessible to the music information retrieval (MIR) community for the testing and evaluation of various MIR techniques. As part of the IMIRSEL project, a cross-platform JAVA based visual programming environment called Music to Knowledge (M2K) is being developed for a variety of music information retrieval related tasks. The primary objective of M2K is to supply the MIR community with a toolset that provides the ability to rapidly prototype algorithms, as well as foster the sharing of techniques within the MIR community through the use of a standardized set of tools. Due to the relatively large size of audio data and the computational costs associated with some digital signal processing and machine learning techniques, M2K is also designed to support distributed computing across computing clusters. In addition, facilities to allow the integration of non-JAVA based (e.g., C/C++, MATLAB, etc.) algorithms and programs are provided within M2K. [Work supported by the Andrew W. Mellon Foundation and NSF Grants No. IIS-0340597 and No. IIS-0327371.
Advantages and disadvantages of technologies for HER2 testing in breast cancer specimens.
Furrer, Daniela; Sanschagrin, François; Jacob, Simon; Diorio, Caroline
2015-11-01
Human epidermal growth factor receptor 2 (HER2) plays a central role as a prognostic and predictive marker in breast cancer specimens. Reliable HER2 evaluation is central to determine the eligibility of patients with breast cancer to targeted anti-HER2 therapies such as trastuzumab and lapatinib. Presently, several methods exist for the determination of HER2 status at different levels (protein, RNA, and DNA level). In this review, we discuss the main advantages and disadvantages of the techniques developed so far for the evaluation of HER2 status in breast cancer specimens. Each technique has its own advantages and disadvantages. It is therefore not surprising that no consensus has been reached so far on which technique is the best for the determination of HER2 status. Currently, emphasis must be put on standardization of procedures, internal and external quality control assessment, and competency evaluation of already existing methods to ensure accurate, reliable, and clinically meaningful test results. Development of new robust and accurate diagnostic assays should also be encouraged. In addition, large clinical trials are warranted to identify the technique that most reliably predicts a positive response to anti-HER2 drugs. Copyright© by the American Society for Clinical Pathology.
The effect of various veneering techniques on the marginal fit of zirconia copings
Torabi, Kianoosh; Vojdani, Mahroo; Giti, Rashin; Pardis, Soheil
2015-01-01
PURPOSE This study aimed to evaluate the fit of zirconia ceramics before and after veneering, using 3 different veneering processes (layering, press-over, and CAD-on techniques). MATERIALS AND METHODS Thirty standardized zirconia CAD/CAM frameworks were constructed and divided into three groups of 10 each. The first group was veneered using the traditional layering technique. Press-over and CAD-on techniques were used to veneer second and third groups. The marginal gap of specimens was measured before and after veneering process at 18 sites on the master die using a digital microscope. Paired t-test was used to evaluate mean marginal gap changes. One-way ANOVA and post hoc tests were also employed for comparison among 3 groups (α=.05). RESULTS Marginal gap of 3 groups was increased after porcelain veneering. The mean marginal gap values after veneering in the layering group (63.06 µm) was higher than press-over (50.64 µm) and CAD-on (51.50 µm) veneered groups (P<.001). CONCLUSION Three veneering methods altered the marginal fit of zirconia copings. Conventional layering technique increased the marginal gap of zirconia framework more than pressing and CAD-on techniques. All ceramic crowns made through three different veneering methods revealed clinically acceptable marginal fit. PMID:26140175
Basaruddin, T.
2016-01-01
One essential task in information extraction from the medical corpus is drug name recognition. Compared with text sources come from other domains, the medical text mining poses more challenges, for example, more unstructured text, the fast growing of new terms addition, a wide range of name variation for the same drug, the lack of labeled dataset sources and external knowledge, and the multiple token representations for a single drug name. Although many approaches have been proposed to overwhelm the task, some problems remained with poor F-score performance (less than 0.75). This paper presents a new treatment in data representation techniques to overcome some of those challenges. We propose three data representation techniques based on the characteristics of word distribution and word similarities as a result of word embedding training. The first technique is evaluated with the standard NN model, that is, MLP. The second technique involves two deep network classifiers, that is, DBN and SAE. The third technique represents the sentence as a sequence that is evaluated with a recurrent NN model, that is, LSTM. In extracting the drug name entities, the third technique gives the best F-score performance compared to the state of the art, with its average F-score being 0.8645. PMID:27843447
Huang, Erich P; Wang, Xiao-Feng; Choudhury, Kingshuk Roy; McShane, Lisa M; Gönen, Mithat; Ye, Jingjing; Buckler, Andrew J; Kinahan, Paul E; Reeves, Anthony P; Jackson, Edward F; Guimaraes, Alexander R; Zahlmann, Gudrun
2015-02-01
Medical imaging serves many roles in patient care and the drug approval process, including assessing treatment response and guiding treatment decisions. These roles often involve a quantitative imaging biomarker, an objectively measured characteristic of the underlying anatomic structure or biochemical process derived from medical images. Before a quantitative imaging biomarker is accepted for use in such roles, the imaging procedure to acquire it must undergo evaluation of its technical performance, which entails assessment of performance metrics such as repeatability and reproducibility of the quantitative imaging biomarker. Ideally, this evaluation will involve quantitative summaries of results from multiple studies to overcome limitations due to the typically small sample sizes of technical performance studies and/or to include a broader range of clinical settings and patient populations. This paper is a review of meta-analysis procedures for such an evaluation, including identification of suitable studies, statistical methodology to evaluate and summarize the performance metrics, and complete and transparent reporting of the results. This review addresses challenges typical of meta-analyses of technical performance, particularly small study sizes, which often causes violations of assumptions underlying standard meta-analysis techniques. Alternative approaches to address these difficulties are also presented; simulation studies indicate that they outperform standard techniques when some studies are small. The meta-analysis procedures presented are also applied to actual [18F]-fluorodeoxyglucose positron emission tomography (FDG-PET) test-retest repeatability data for illustrative purposes. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Huang, Erich P; Wang, Xiao-Feng; Choudhury, Kingshuk Roy; McShane, Lisa M; Gönen, Mithat; Ye, Jingjing; Buckler, Andrew J; Kinahan, Paul E; Reeves, Anthony P; Jackson, Edward F; Guimaraes, Alexander R; Zahlmann, Gudrun
2017-01-01
Medical imaging serves many roles in patient care and the drug approval process, including assessing treatment response and guiding treatment decisions. These roles often involve a quantitative imaging biomarker, an objectively measured characteristic of the underlying anatomic structure or biochemical process derived from medical images. Before a quantitative imaging biomarker is accepted for use in such roles, the imaging procedure to acquire it must undergo evaluation of its technical performance, which entails assessment of performance metrics such as repeatability and reproducibility of the quantitative imaging biomarker. Ideally, this evaluation will involve quantitative summaries of results from multiple studies to overcome limitations due to the typically small sample sizes of technical performance studies and/or to include a broader range of clinical settings and patient populations. This paper is a review of meta-analysis procedures for such an evaluation, including identification of suitable studies, statistical methodology to evaluate and summarize the performance metrics, and complete and transparent reporting of the results. This review addresses challenges typical of meta-analyses of technical performance, particularly small study sizes, which often causes violations of assumptions underlying standard meta-analysis techniques. Alternative approaches to address these difficulties are also presented; simulation studies indicate that they outperform standard techniques when some studies are small. The meta-analysis procedures presented are also applied to actual [18F]-fluorodeoxyglucose positron emission tomography (FDG-PET) test–retest repeatability data for illustrative purposes. PMID:24872353
Calon, Tim G A; van Hoof, Marc; van den Berge, Herbert; de Bruijn, Arthur J G; van Tongeren, Joost; Hof, Janny R; Brunings, Jan Wouter; Jonhede, Sofia; Anteunis, Lucien J C; Janssen, Miranda; Joore, Manuela A; Holmberg, Marcus; Johansson, Martin L; Stokroos, Robert J
2016-11-09
Over the last years, less invasive surgical techniques with soft tissue preservation for bone conduction hearing implants (BCHI) have been introduced such as the linear incision technique combined with a punch. Results using this technique seem favorable in terms of rate of peri-abutment dermatitis (PAD), esthetics, and preservation of skin sensibility. Recently, a new standardized surgical technique for BCHI placement, the Minimally Invasive Ponto Surgery (MIPS) technique has been developed by Oticon Medical AB (Askim, Sweden). This technique aims to standardize surgery by using a novel surgical instrumentation kit and minimize soft tissue trauma. A multicenter randomized controlled trial is designed to compare the MIPS technique to the linear incision technique with soft tissue preservation. The primary investigation center is Maastricht University Medical Center. Sixty-two participants will be included with a 2-year follow-up period. Parameters are introduced to quantify factors such as loss of skin sensibility, dehiscence of the skin next to the abutment, skin overgrowth, and cosmetic results. A new type of sampling method is incorporated to aid in the estimation of complications. To gain further understanding of PAD, swabs and skin biopsies are collected during follow-up visits for evaluation of the bacterial profile and inflammatory cytokine expression. The primary objective of the study is to compare the incidence of PAD during the first 3 months after BCHI placement. Secondary objectives include the assessment of parameters related to surgery, wound healing, pain, loss of sensibility of the skin around the implant, implant extrusion rate, implant stability measurements, dehiscence of the skin next to the abutment, and esthetic appeal. Tertiary objectives include assessment of other factors related to PAD and a health economic evaluation. This is the first trial to compare the recently developed MIPS technique to the linear incision technique with soft tissue preservation for BCHI surgery. Newly introduced parameters and sampling method will aid in the prediction of results and complications after BCHI placement. Registered at the CCMO register in the Netherlands on 24 November 2014: NL50072.068.14 . Retrospectively registered on 21 April 2015 at ClinicalTrials.gov: NCT02438618 . This trial is sponsored by Oticon Medical AB.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Takam, Rungdham; Bezak, Eva; Yeoh, Eric E.
2010-09-15
Purpose: Normal tissue complication probability (NTCP) of the rectum, bladder, urethra, and femoral heads following several techniques for radiation treatment of prostate cancer were evaluated applying the relative seriality and Lyman models. Methods: Model parameters from literature were used in this evaluation. The treatment techniques included external (standard fractionated, hypofractionated, and dose-escalated) three-dimensional conformal radiotherapy (3D-CRT), low-dose-rate (LDR) brachytherapy (I-125 seeds), and high-dose-rate (HDR) brachytherapy (Ir-192 source). Dose-volume histograms (DVHs) of the rectum, bladder, and urethra retrieved from corresponding treatment planning systems were converted to biological effective dose-based and equivalent dose-based DVHs, respectively, in order to account for differences inmore » radiation treatment modality and fractionation schedule. Results: Results indicated that with hypofractionated 3D-CRT (20 fractions of 2.75 Gy/fraction delivered five times/week to total dose of 55 Gy), NTCP of the rectum, bladder, and urethra were less than those for standard fractionated 3D-CRT using a four-field technique (32 fractions of 2 Gy/fraction delivered five times/week to total dose of 64 Gy) and dose-escalated 3D-CRT. Rectal and bladder NTCPs (5.2% and 6.6%, respectively) following the dose-escalated four-field 3D-CRT (2 Gy/fraction to total dose of 74 Gy) were the highest among analyzed treatment techniques. The average NTCP for the rectum and urethra were 0.6% and 24.7% for LDR-BT and 0.5% and 11.2% for HDR-BT. Conclusions: Although brachytherapy techniques resulted in delivering larger equivalent doses to normal tissues, the corresponding NTCPs were lower than those of external beam techniques other than the urethra because of much smaller volumes irradiated to higher doses. Among analyzed normal tissues, the femoral heads were found to have the lowest probability of complications as most of their volume was irradiated to lower equivalent doses compared to other tissues.« less
Relevance similarity: an alternative means to monitor information retrieval systems
Dong, Peng; Loh, Marie; Mondry, Adrian
2005-01-01
Background Relevance assessment is a major problem in the evaluation of information retrieval systems. The work presented here introduces a new parameter, "Relevance Similarity", for the measurement of the variation of relevance assessment. In a situation where individual assessment can be compared with a gold standard, this parameter is used to study the effect of such variation on the performance of a medical information retrieval system. In such a setting, Relevance Similarity is the ratio of assessors who rank a given document same as the gold standard over the total number of assessors in the group. Methods The study was carried out on a collection of Critically Appraised Topics (CATs). Twelve volunteers were divided into two groups of people according to their domain knowledge. They assessed the relevance of retrieved topics obtained by querying a meta-search engine with ten keywords related to medical science. Their assessments were compared to the gold standard assessment, and Relevance Similarities were calculated as the ratio of positive concordance with the gold standard for each topic. Results The similarity comparison among groups showed that a higher degree of agreements exists among evaluators with more subject knowledge. The performance of the retrieval system was not significantly different as a result of the variations in relevance assessment in this particular query set. Conclusion In assessment situations where evaluators can be compared to a gold standard, Relevance Similarity provides an alternative evaluation technique to the commonly used kappa scores, which may give paradoxically low scores in highly biased situations such as document repositories containing large quantities of relevant data. PMID:16029513
Using normalization 3D model for automatic clinical brain quantative analysis and evaluation
NASA Astrophysics Data System (ADS)
Lin, Hong-Dun; Yao, Wei-Jen; Hwang, Wen-Ju; Chung, Being-Tau; Lin, Kang-Ping
2003-05-01
Functional medical imaging, such as PET or SPECT, is capable of revealing physiological functions of the brain, and has been broadly used in diagnosing brain disorders by clinically quantitative analysis for many years. In routine procedures, physicians manually select desired ROIs from structural MR images and then obtain physiological information from correspondent functional PET or SPECT images. The accuracy of quantitative analysis thus relies on that of the subjectively selected ROIs. Therefore, standardizing the analysis procedure is fundamental and important in improving the analysis outcome. In this paper, we propose and evaluate a normalization procedure with a standard 3D-brain model to achieve precise quantitative analysis. In the normalization process, the mutual information registration technique was applied for realigning functional medical images to standard structural medical images. Then, the standard 3D-brain model that shows well-defined brain regions was used, replacing the manual ROIs in the objective clinical analysis. To validate the performance, twenty cases of I-123 IBZM SPECT images were used in practical clinical evaluation. The results show that the quantitative analysis outcomes obtained from this automated method are in agreement with the clinical diagnosis evaluation score with less than 3% error in average. To sum up, the method takes advantage of obtaining precise VOIs, information automatically by well-defined standard 3-D brain model, sparing manually drawn ROIs slice by slice from structural medical images in traditional procedure. That is, the method not only can provide precise analysis results, but also improve the process rate for mass medical images in clinical.
Long-term Outcomes of Elective Surgery for Diverticular Disease: A Call for Standardization.
Biondi, Alberto; Santullo, Francesco; Fico, Valeria; Persiani, Roberto
2016-10-01
To date, the appropriate management of diverticular disease is still controversial. The American Society of Colon and Rectal Surgeons declared that the decision between conservative or surgical approach should be taken by a case-by-case evaluation. There is still lack of evidence in literature about long-term outcomes after elective sigmoid resection for diverticular disease. Considering the potentially key role of the surgical technique in long-term outcomes, there is the need for surgeons to define strict rules to standardize the surgical technique. Currently there are 5 areas of debate in elective surgery for diverticular disease: laparoscopic versus open approach, the site of the proximal and distal colonic division, the vascular approach and the mobilization of the splenic flexure. The purpose of this paper is to review existing knowledge about technical aspects, which represent how the surgeon is able to affect the long-term results.
Scattering of cylindrical electric field waves from an elliptical dielectric cylindrical shell
NASA Astrophysics Data System (ADS)
Urbanik, E. A.
1982-12-01
This thesis examines the scattering of cylindrical waves by large dielectric scatterers of elliptic cross section. The solution method was the method of moments using a Galerkin approach. Sinusoidal basis and testing functions were used resulting in a higher convergence rate. The higher rate of convergence made it possible for the program to run on the Aeronautical Systems Division's CYBER computers without any special storage methods. This report includes discussion on moment methods, solution of integral equations, and the relationship between the electric field and the source region or self cell singularity. Since the program produced unacceptable run times, no results are contained herein. The importance of this work is the evaluation of the practicality of moment methods using standard techniques. The long run times for a mid-sized scatterer demonstrate the impracticality of moment methods for dielectrics using standard techniques.
Grayscale standard display function on LCD color monitors
NASA Astrophysics Data System (ADS)
De Monte, Denis; Casale, Carlo; Albani, Luigi; Bonfiglio, Silvio
2007-03-01
Currently, as a rule, digital medical systems use monochromatic Liquid Crystal Display (LCD) monitors to ensure an accurate reproduction of the Grayscale Standard Display Function (GSDF) as specified in the Digital Imaging and Communications in Medicine (DICOM) Standard. As a drawback, special panels need to be utilized in digital medical systems, while it would be preferable to use regular color panels, which are manufactured on a wide scale and are thus available at by far lower prices. The method proposed introduces a temporal color dithering technique to accurately reproduce the GSDF on color monitors without losing monitor resolution. By exploiting the characteristics of the Human Visual System (HVS) the technique ensures that a satisfactory grayscale reproduction is achieved minimizing perceivable flickering and undesired color artifacts. The algorithm has been implemented in the monitor using a low-cost Field Programmable Gate Array (FPGA). Quantitative evaluations of luminance response on a 3 Mega-pixel color monitor have shown that the compliance with the GSDF can be achieved with the accuracy level required by medical applications. At the same time the measured color deviation is below the threshold perceivable by the human eye.
Nowacki, Maciej; Nazarewski, Łukasz; Kloskowski, Tomasz; Tyloch, Dominik; Pokrywczyńska, Marta; Pietkun, Katarzyna; Jundziłł, Arkadiusz; Tyloch, Janusz; Habib, Samy L; Drewa, Tomasz
2016-10-01
On the 60 th anniversary of the first successfully performed renal transplantation, we summarize the historical, current and potential future status of kidney transplantation. We discuss three different aspects with a potential significant influence on kidney transplantation progress: the development of surgical techniques, the influence of regenerative medicine and tissue engineering, and changes in immunosuppression. We evaluate the standard open surgical procedures with modern techniques and compare them to less invasive videoscopic as well as robotic techniques. The role of tissue engineering and regenerative medicine as a potential method for future kidney regeneration or replacement and the interesting search for novel solutions in the field of immunosuppression will be discussed. After 60 years since the first successfully performed kidney transplantation, we can conclude that the greatest achievements are associated with the development of surgical techniques and with planned systemic immunosuppression.
Nowacki, Maciej; Nazarewski, Łukasz; Tyloch, Dominik; Pokrywczyńska, Marta; Pietkun, Katarzyna; Jundziłł, Arkadiusz; Tyloch, Janusz; Habib, Samy L.; Drewa, Tomasz
2016-01-01
On the 60th anniversary of the first successfully performed renal transplantation, we summarize the historical, current and potential future status of kidney transplantation. We discuss three different aspects with a potential significant influence on kidney transplantation progress: the development of surgical techniques, the influence of regenerative medicine and tissue engineering, and changes in immunosuppression. We evaluate the standard open surgical procedures with modern techniques and compare them to less invasive videoscopic as well as robotic techniques. The role of tissue engineering and regenerative medicine as a potential method for future kidney regeneration or replacement and the interesting search for novel solutions in the field of immunosuppression will be discussed. After 60 years since the first successfully performed kidney transplantation, we can conclude that the greatest achievements are associated with the development of surgical techniques and with planned systemic immunosuppression. PMID:27695507
Effect of incremental filling technique on adhesion of light-cured resin composite to cavity floor.
Chikawa, Hirokazu; Inai, Norimichi; Cho, Eitetsu; Kishikawa, Ryuzo; Otsuki, Masayuki; Foxton, Richard M; Tagami, Junji
2006-09-01
The purpose of this study was to evaluate the effect of various incremental filling techniques on adhesion between composite and cavity floor using light-cured resin composite. Black ABS resin and hybrid resin composite were used as mold materials--instead of dentin--for the preparation of cavities, and standardized to 5x5x5 mm. Each cavity was then treated with a bonding system (Clearfil SE bond). Resin composite (Clearfil Photo Core) was placed on the bonding resin using different incremental filling techniques or in bulk and irradiated for a total of 80 seconds using a halogen light unit. Specimens were subjected to the micro-tensile bond test at a crosshead speed of 1 mm/min. Data were analyzed by two-way ANOVA. The results indicated that an incremental filling technique was more effective in improving adhesion to the cavity floor than a bulk filling technique.
NASA Astrophysics Data System (ADS)
Trappe, Neil; Murphy, J. Anthony; Withington, Stafford
2003-07-01
Gaussian beam mode analysis (GBMA) offers a more intuitive physical insight into how light beams evolve as they propagate than the conventional Fresnel diffraction integral approach. In this paper we illustrate that GBMA is a computationally efficient, alternative technique for tracing the evolution of a diffracting coherent beam. In previous papers we demonstrated the straightforward application of GBMA to the computation of the classical diffraction patterns associated with a range of standard apertures. In this paper we show how the GBMA technique can be expanded to investigate the effects of aberrations in the presence of diffraction by introducing the appropriate phase error term into the propagating quasi-optical beam. We compare our technique to the standard diffraction integral calculation for coma, astigmatism and spherical aberration, taking—for comparison—examples from the classic text 'Principles of Optics' by Born and Wolf. We show the advantages of GBMA for allowing the defocusing of an aberrated image to be evaluated quickly, which is particularly important and useful for probing the consequences of astigmatism and spherical aberration.
Short-wavelength automated perimetry and frequency-doubling technology perimetry in glaucoma.
Fogagnolo, Paolo; Rossetti, Luca; Ranno, Stefano; Ferreras, Antonio; Orzalesi, Nicola
2008-01-01
Standard automated perimetry (SAP) is today still the clinical standard for the management of glaucoma and its progression, though it has been shown that it may detect the disease only after the death of a high number of retinal ganglion cells (RGCs). A number of "unconventional" perimetries have recently been evaluated by several clinical studies which showed their ability to identify the earliest glaucoma changes; the most promising of these techniques are short-wavelength automated perimetry (SWAP) and frequency-doubling technology perimetry (FDT). The applicability of these techniques is still limited by a number of factors: the limited economic resources allocated to perimetry; the paucity of well-conducted, prospective longitudinal studies showing the superiority of SWAP and FDT over SAP; and the lack of a consensus on the criteria to define test abnormality with these techniques. The aim of this article is to review the rationale, the limits, and the potentiality of SWAP and FDT for glaucoma management and to summarize the tasks required to improve the clinical usefulness of these two instruments in the future.
Farzan, Faranak; Vernet, Marine; Shafi, Mouhsin M D; Rotenberg, Alexander; Daskalakis, Zafiris J; Pascual-Leone, Alvaro
2016-01-01
The concurrent combination of transcranial magnetic stimulation (TMS) with electroencephalography (TMS-EEG) is a powerful technology for characterizing and modulating brain networks across developmental, behavioral, and disease states. Given the global initiatives in mapping the human brain, recognition of the utility of this technique is growing across neuroscience disciplines. Importantly, TMS-EEG offers translational biomarkers that can be applied in health and disease, across the lifespan, and in humans and animals, bridging the gap between animal models and human studies. However, to utilize the full potential of TMS-EEG methodology, standardization of TMS-EEG study protocols is needed. In this article, we review the principles of TMS-EEG methodology, factors impacting TMS-EEG outcome measures, and the techniques for preventing and correcting artifacts in TMS-EEG data. To promote the standardization of this technique, we provide comprehensive guides for designing TMS-EEG studies and conducting TMS-EEG experiments. We conclude by reviewing the application of TMS-EEG in basic, cognitive and clinical neurosciences, and evaluate the potential of this emerging technology in brain research.
Farzan, Faranak; Vernet, Marine; Shafi, Mouhsin M. D.; Rotenberg, Alexander; Daskalakis, Zafiris J.; Pascual-Leone, Alvaro
2016-01-01
The concurrent combination of transcranial magnetic stimulation (TMS) with electroencephalography (TMS-EEG) is a powerful technology for characterizing and modulating brain networks across developmental, behavioral, and disease states. Given the global initiatives in mapping the human brain, recognition of the utility of this technique is growing across neuroscience disciplines. Importantly, TMS-EEG offers translational biomarkers that can be applied in health and disease, across the lifespan, and in humans and animals, bridging the gap between animal models and human studies. However, to utilize the full potential of TMS-EEG methodology, standardization of TMS-EEG study protocols is needed. In this article, we review the principles of TMS-EEG methodology, factors impacting TMS-EEG outcome measures, and the techniques for preventing and correcting artifacts in TMS-EEG data. To promote the standardization of this technique, we provide comprehensive guides for designing TMS-EEG studies and conducting TMS-EEG experiments. We conclude by reviewing the application of TMS-EEG in basic, cognitive and clinical neurosciences, and evaluate the potential of this emerging technology in brain research. PMID:27713691
ASSESSING AND COMBINING RELIABILITY OF PROTEIN INTERACTION SOURCES
LEACH, SONIA; GABOW, AARON; HUNTER, LAWRENCE; GOLDBERG, DEBRA S.
2008-01-01
Integrating diverse sources of interaction information to create protein networks requires strategies sensitive to differences in accuracy and coverage of each source. Previous integration approaches calculate reliabilities of protein interaction information sources based on congruity to a designated ‘gold standard.’ In this paper, we provide a comparison of the two most popular existing approaches and propose a novel alternative for assessing reliabilities which does not require a gold standard. We identify a new method for combining the resultant reliabilities and compare it against an existing method. Further, we propose an extrinsic approach to evaluation of reliability estimates, considering their influence on the downstream tasks of inferring protein function and learning regulatory networks from expression data. Results using this evaluation method show 1) our method for reliability estimation is an attractive alternative to those requiring a gold standard and 2) the new method for combining reliabilities is less sensitive to noise in reliability assignments than the similar existing technique. PMID:17990508
ERIC Educational Resources Information Center
Pinkerton, Steven D.; Benotsch, Eric G.; Mikytuck, John
2007-01-01
The "gold standard" for evaluating human immunodeficiency virus (HIV) prevention programs is a partner-by-partner sexual behavior assessment that elicits information about each sex partner and the activities engaged in with that partner. When collection of detailed partner-by-partner data is not feasible, aggregate data (e.g., total…
Research and Development on Titanium Alloys
1949-10-31
EVALUATION OF EPERIMENTAL TITANIUM-BASE ALLOYS• 65 Binary Alloys of Titanium . . . . .. 65 Titanium-Silver Alloys. . . . . ..... ... 68 Mechanical Properties...using a technique in melting designed to give more uniform distribution of the alloying additions. NMATTWLL MOMORIAL INSTITUTE 4...tc Dr. Derge for analysis. BATTELLE MEMORIAL INSTITUTE -107- 2TABLE 28. OXYGEN STANDARDS FOR ANALYSIS Wt fSapl Pein Cen Designation Sample lielting, 1
The sterility of hospital-prepared Soffban bandages.
Wood, E V; Fenwick, H; Manning, M P; Mobbs, P
2005-11-01
An evaluation of the sterility of hospital-prepared Soffban bandages was undertaken. Discs of Bacillus stearothermophilus were inserted into the bandage rolls, prior to sterilization in "porous load" autoclaves. The discs were subsequently removed and placed in culture media, with growth of the organism indicating failure of sterilization. It was demonstrated that Soffban could not be sterilized reliably using standard hospital autoclave techniques.
ERIC Educational Resources Information Center
Chung, Gregory K. W. K.; Choi, Kilchan; Baker, Eva L.; Cai, Li
2014-01-01
A large-scale randomized controlled trial tested the effects of researcher-developed learning games on a transfer measure of fractions knowledge. The measure contained items similar to standardized assessments. Thirty treatment and 29 control classrooms (~1500 students, 9 districts, 26 schools) participated in the study. Students in treatment…
Biomagnetic Pair Therapy and Typhoid Fever: A Pilot Study.
Frank, Bryan L
2017-10-01
Objective: This pilot study examined the laboratory responses of patients with laboratory-documented typhoid fever who were treated with Biomagnetic Pair Therapy (BPT; medical biomagnetism), a specific application of pairs of magnets for various ailments that are infectious and otherwise. Materials and Methods: This study was an assessment of patients' response to treatment with only BPT for Salmonella typhi infections (typhoid fever) using standard conventional laboratory techniques. The research was conducted in an outpatient village clinic in Kenya. There were 52 participants who were evaluated for possible systemic illness, including typhoid fever, from an open-label study. Participants who felt sick and requested testing for possible typhoid fever were tested with a standard Widal test by a certified laboratory technician. Participants who tested positive (13 patients) were then treated with BPT (a "First Aid" approach) only. These participants then returned for follow-up laboratory and clinical evaluations after 2 days. Results: Most of the participants (10 of 13) retested as negative, and all patients reported symptomatic clinical improvement. Conclusions: As a significant majority of participants demonstrated clearing of their S. typhi after BPT, this technique should be studied further in larger trials for its efficacy in treating typhoid fever.
Morcellized Omental Transfer for Severe HIV Facial Wasting
Bohorquez, Marlon; Podbielski, Francis J.
2013-01-01
Background: A novel surgical technique to reconstruct facial wasting was developed for patients with severe human immunodeficiency virus lipoatrophy and no source of subcutaneous fat for donor material. Fourteen patients underwent endoscopic harvest of omentum, extracorporeal morcellation, and autologous transfer to the face. Methods: Omental fat was harvested using a standard 3-port laparoscopic technique. A mechanical tissue processor created morsels suitable for transfer. Gold-plated, multi-holed catheters delivered living particulate fat to the subcutaneous planes of the buccal, malar, lateral cheek, and temporal regions. Results were evaluated using standardized pre- and postoperative photographs for specific anatomic criteria found along the typical progression of the disease process. Results: Electron microscopy confirmed that morcellized fat retained intact cell walls and was appropriate for autologous transfer. Complications were minor and transient. Patients were discharged home within 24 hours. No patient required open laparotomy. Survival of the adipose grafts was deemed good to excellent in 13 of the 14 cases. Conclusions: Mechanically morcellized omental fat transfer provides a safe option to restore facial volume in those unusual patients with severe wasting and no available subcutaneous tissue for transfer. Consistent anatomic progression of facial wasting permits preoperative classification, counseling of patients, and postoperative evaluation of surgical improvement. PMID:25289268
Hoffmann, Alexandra; Bleser, Gabriele
2017-01-01
Background Chronic stress has been shown to be associated with disease. This link is not only direct but also indirect through harmful health behavior such as smoking or changing eating habits. The recent mHealth trend offers a new and promising approach to support the adoption and maintenance of appropriate stress management techniques. However, only few studies have dealt with the inclusion of evidence-based content within stress management apps for mobile phones. Objective The aim of this study was to evaluate stress management apps on the basis of a new taxonomy of effective emotion-focused stress management techniques and an established taxonomy of behavior change techniques. Methods Two trained and independent raters evaluated 62 free apps found in Google Play with regard to 26 behavior change and 15 emotion-focused stress management techniques in October 2015. Results The apps included an average of 4.3 behavior change techniques (SD 4.2) and 2.8 emotion-focused stress management techniques (SD 2.6). The behavior change technique score and stress management technique score were highly correlated (r=.82, P=.01). Conclusions The broad variation of different stress management strategies found in this sample of apps goes in line with those found in conventional stress management interventions and self-help literature. Moreover, this study provided a first step toward more detailed and standardized taxonomies, which can be used to investigate evidence-based content in stress management interventions and enable greater comparability between different intervention types. PMID:28232299
Forkey, Joseph N.; Quinlan, Margot E.; Goldman, Yale E.
2005-01-01
A new approach is presented for measuring the three-dimensional orientation of individual macromolecules using single molecule fluorescence polarization (SMFP) microscopy. The technique uses the unique polarizations of evanescent waves generated by total internal reflection to excite the dipole moment of individual fluorophores. To evaluate the new SMFP technique, single molecule orientation measurements from sparsely labeled F-actin are compared to ensemble-averaged orientation data from similarly prepared densely labeled F-actin. Standard deviations of the SMFP measurements taken at 40 ms time intervals indicate that the uncertainty for individual measurements of axial and azimuthal angles is ∼10° at 40 ms time resolution. Comparison with ensemble data shows there are no substantial systematic errors associated with the single molecule measurements. In addition to evaluating the technique, the data also provide a new measurement of the torsional rigidity of F-actin. These measurements support the smaller of two values of the torsional rigidity of F-actin previously reported. PMID:15894632
Investigation of the tone-burst tube for duct lining attenuation measurement
NASA Technical Reports Server (NTRS)
Soffel, A. R.; Morrow, P. F.
1972-01-01
The tone burst technique makes practical the laboratory evaluation of potential inlet and discharge duct treatments. Tone burst apparatus requires only simple machined parts and standard components. Small, simply made, lining samples are quickly and easily installed in the system. Two small electromagnetric loudspeaker drivers produce peak sound pressure level of over 166 db in the 3-square-inch sample duct. Air pump available in most laboratories can produce air flows of over plus and minus Mach 0.3 in the sample duct. The technique uses short shaped pulses of sound propagated down a progressive wave tube containing the sample duct. The peak pressure level output of the treated duct is compared with the peak pressure level output of a substituted reference duct. The difference between the levels is the attenuation or insertion loss of the treated duct. Evaluations of resonant absorber linings by the tone burst technique check attenuation values predicted by empirical formulas based on full scale ducts.
25 years of neuroimaging in amyotrophic lateral sclerosis.
Foerster, Bradley R; Welsh, Robert C; Feldman, Eva L
2013-09-01
Amyotrophic lateral sclerosis (ALS) is a fatal motor neuron disease for which a precise cause has not yet been identified. Standard CT or MRI evaluation does not demonstrate gross structural nervous system changes in ALS, so conventional neuroimaging techniques have provided little insight into the pathophysiology of this disease. Advanced neuroimaging techniques--such as structural MRI, diffusion tensor imaging and proton magnetic resonance spectroscopy--allow evaluation of alterations of the nervous system in ALS. These alterations include focal loss of grey and white matter and reductions in white matter tract integrity, as well as changes in neural networks and in the chemistry, metabolism and receptor distribution in the brain. Given their potential for investigation of both brain structure and function, advanced neuroimaging methods offer important opportunities to improve diagnosis, guide prognosis, and direct future treatment strategies in ALS. In this article, we review the contributions made by various advanced neuroimaging techniques to our understanding of the impact of ALS on different brain regions, and the potential role of such measures in biomarker development.
On evaluating compliance with air pollution levels 'not to be exceeded more than once per year'
NASA Technical Reports Server (NTRS)
Neustadter, H. E.; Sidik, S. M.
1974-01-01
The point of view taken is that the Environmental Protection Agency (EPA) Air Quality Standards (AQS) represent conditions which must be made to exist in the ambient environment. The statistical techniques developed should serve as tools for measuring the closeness to achieving the desired quality of air. It is shown that the sampling frequency recommended by EPA is inadequate to meet these objectives when the standard is expressed as a level not to be exceeded more than once per year and sampling frequency is once every three days or less frequent.
Spalla, I; Locatelli, C; Zanaboni, A M; Brambilla, P; Bussadori, C
2016-05-01
Patent ductus arteriosus (PDA) is one of the most common congenital heart defects in dogs. Advanced echocardiographic techniques such as speckle-tracking echocardiography (STE) have not been extensively used to evaluate cardiac function in affected dogs. Advanced echocardiographic techniques are more sensitive than standard echocardiographic techniques in analyzing systolic function in dogs with PDA. Forty-four client-owned dogs: 34 dogs with PDA (preoperative evaluation) and 10 healthy sex- and weight-matched controls. Prospective study. Dogs were recruited over a 2-year period. Complete echocardiographic evaluation was performed, including conventional (end-diastolic volumes indexed to body surface area in B and M-mode [EDVIB /M ], end-systolic volumes indexed to body surface area in B and M-mode [ESVIB /M ], allometric scaling in diastole and systole [AlloD/S], pulmonary flow to systemic flow [Qp/Qs], ejection fraction [EF] and fractional shortening [FS]) and speckle-tracking echocardiography ([STE]: global longitudinal, radial and circumferential strain [S] and strain rate [SR]). Dogs with PDA had significantly different EDVIB /M , ESVIB /M , AlloD/S, Qp/Qs and all STE-derived parameters (global longitudinal S and SR, global circumferential S and SR, global radial S and SR)compared to healthy dogs. No correlation was found between standard techniques (EDVIB /M , ESVIB /M , AlloD/S, Qp/Qs) and STE-derived parameters (global longitudinal, circumferential and radial S and SR). Conventional parameters routinely used to assess systolic function (EF and FS) were not different between the groups; STE-derived parameters identified subtle changes in cardiac systolic function and contractility between the 2 groups of dogs. Based on these findings, STE may be a more appropriate tool to assess cardiac contractility in dogs with PDA. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.
Bujar, Magdalena; McAuslane, Neil; Walker, Stuart R.; Salek, Sam
2017-01-01
Introduction: Although pharmaceutical companies, regulatory authorities, and health technology assessment (HTA) agencies have been increasingly using decision-making frameworks, it is not certain whether these enable better quality decision making. This could be addressed by formally evaluating the quality of decision-making process within those organizations. The aim of this literature review was to identify current techniques (tools, questionnaires, surveys, and studies) for measuring the quality of the decision-making process across the three stakeholders. Methods: Using MEDLINE, Web of Knowledge, and other Internet-based search engines, a literature review was performed to systematically identify techniques for assessing quality of decision making in medicines development, regulatory review, and HTA. A structured search was applied using key words and a secondary review was carried out. In addition, the measurement properties of each technique were assessed and compared. Ten Quality Decision-Making Practices (QDMPs) developed previously were then used as a framework for the evaluation of techniques identified in the review. Due to the variation in studies identified, meta-analysis was inappropriate. Results: This review identified 13 techniques, where 7 were developed specifically to assess decision making in medicines' development, regulatory review, or HTA; 2 examined corporate decision making, and 4 general decision making. Regarding how closely each technique conformed to the 10 QDMPs, the 13 techniques assessed a median of 6 QDMPs, with a mode of 3 QDMPs. Only 2 techniques evaluated all 10 QDMPs, namely the Organizational IQ and the Quality of Decision Making Orientation Scheme (QoDoS), of which only one technique, QoDoS could be applied to assess decision making of both individuals and organizations, and it possessed generalizability to capture issues relevant to companies as well as regulatory authorities. Conclusion: This review confirmed a general paucity of research in this area, particularly regarding the development and systematic application of techniques for evaluating quality decision making, with no consensus around a gold standard. This review has identified QoDoS as the most promising available technique for assessing decision making in the lifecycle of medicines and the next steps would be to further test its validity, sensitivity, and reliability. PMID:28443022
Advances in Liposuction: Five Key Principles with Emphasis on Patient Safety and Outcomes
Tabbal, Geo N.; Ahmad, Jamil; Lista, Frank
2013-01-01
Summary: Since Illouz’s presentation of a technique for lipoplasty at the 1982 Annual Meeting of the American Society of Plastic and Reconstructive Surgeons, liposuction has become one of the most commonly performed aesthetic surgery procedures. The evolution of liposuction has seen refinements in technique and improvement of patient safety-related standards of care. Based on long-term experience with body contouring surgery, 5 principles of advanced liposuction are presented: preoperative evaluation and planning, intraoperative monitoring—safety measures, the role of wetting solutions and fluid resuscitation, circumferential contouring and complication prevention, and outcomes measurement. PMID:25289270
Applications of remote sensing, volume 3
NASA Technical Reports Server (NTRS)
Landgrebe, D. A. (Principal Investigator)
1977-01-01
The author has identified the following significant results. Of the four change detection techniques (post classification comparison, delta data, spectral/temporal, and layered spectral temporal), the post classification comparison was selected for further development. This was based upon test performances of the four change detection method, straightforwardness of the procedures, and the output products desired. A standardized modified, supervised classification procedure for analyzing the Texas coastal zone data was compiled. This procedure was developed in order that all quadrangles in the study are would be classified using similar analysis techniques to allow for meaningful comparisons and evaluations of the classifications.
Sampling methods for microbiological analysis of red meat and poultry carcasses.
Capita, Rosa; Prieto, Miguel; Alonso-Calleja, Carlos
2004-06-01
Microbiological analysis of carcasses at slaughterhouses is required in the European Union for evaluating the hygienic performance of carcass production processes as required for effective hazard analysis critical control point implementation. The European Union microbial performance standards refer exclusively to the excision method, even though swabbing using the wet/dry technique is also permitted when correlation between both destructive and nondestructive methods can be established. For practical and economic reasons, the swab technique is the most extensively used carcass surface-sampling method. The main characteristics, advantages, and limitations of the common excision and swabbing methods are described here.
Jayakody, Chatura; Hull-Ryde, Emily A
2016-01-01
Well-defined quality control (QC) processes are used to determine whether a certain procedure or action conforms to a widely accepted standard and/or set of guidelines, and are important components of any laboratory quality assurance program (Popa-Burke et al., J Biomol Screen 14: 1017-1030, 2009). In this chapter, we describe QC procedures useful for monitoring the accuracy and precision of laboratory instrumentation, most notably automated liquid dispensers. Two techniques, gravimetric QC and photometric QC, are highlighted in this chapter. When used together, these simple techniques provide a robust process for evaluating liquid handler accuracy and precision, and critically underpin high-quality research programs.
Leischik, Roman; Littwitz, Henning; Dworrak, Birgit; Garg, Pankaj; Zhu, Meihua; Sahn, David J; Horlitz, Marc
2015-01-01
Left atrial (LA) functional analysis has an established role in assessing left ventricular diastolic function. The current standard echocardiographic parameters used to study left ventricular diastolic function include pulsed-wave Doppler mitral inflow analysis, tissue Doppler imaging measurements, and LA dimension estimation. However, the above-mentioned parameters do not directly quantify LA performance. Deformation studies using strain and strain-rate imaging to assess LA function were validated in previous research, but this technique is not currently used in routine clinical practice. This review discusses the history, importance, and pitfalls of strain technology for the analysis of LA mechanics.
Transverse mucoperiosteal flap inset by rotation for cleft palate repair: technique and outcomes.
Black, Jonathan S; Gampper, Thomas J
2014-01-01
Cleft palate is a relatively common deformity with various techniques described for its repair. Most techniques address the hard palate portion of the cleft with bilateral mucoperiosteal flaps transposed to the midline. This results in superimposed, linear closure layers directly over the cleft and may predispose the repair to oronasal fistula formation. This report details an alternative technique of flap rotation with an outcome analysis. A retrospective chart analysis was performed of all patients having undergone primary palatoplasty for cleft palate. Demographics and cleft Veau type were recorded. Postoperative speech outcomes were assessed by standardized speech evaluation performed by 2 speech language pathologists. The presence and location of oronasal fistulae was assessed and recorded by the surgeon and speech language pathologists in follow-up evaluations. The study revealed an overall incidence of velopharyngeal insufficiency of 5.7% using this surgical technique. It also revealed a fistula rate of 8.6%. Secondary surgery has been successful in those patients in which it was indicated. Eleven (31%) patients were diagnosed with Robin sequence. This technique demonstrates excellent early outcomes in a difficult subset of cleft patients including a high proportion of those with Pierre Robin sequence. The technique addresses the inherent disadvantages to a linear closure over the bony cleft. The variability in its design provides the surgeon another option for correction of this deformity.
Ismail, Mostafa; Fares, Abd Alla; Abdelhak, Balegh; D'Haens, Jean; Michel, Olaf
2016-01-01
Sellar reconstruction with intrasellar packing following endoscopic resection of pituitary macroadenomas remains a subject of clinical and radiological discussion particularly, when an intraoperative cerebrospinal fluid (CSF) leakage is absent. This study was conducted to contribute our experience with sellar reconstruction after a standard endoscopic surgery of pituitary macroadenomas without intraoperative CSF leakage to the ongoing discussion between techniques with and without intrasellar packing. A consecutive series of 47 pituitary macroadenomas undergoing excision via a standard endoscopic endonasal transsphenoidal surgery (EETS) without evident intraoperative CSF leakage were retrospectively evaluated over a 10-months mean follow-up period. According to the sellar reconstruction technique, three groups could be identified: Group A - with no intrasellar packing, Group B - with haemostatic materials packing, and Group C - with abdominal fat packing. Postoperative clinical and radiological assessments of the three groups were documented and analyzed for differences in outcome. Postoperative clinical assessment did not differ significantly between the three groups. In group A, postoperative CSF leakage, sphenoid sinusitis and empty sella syndrome were not observed. However, a significant difference in radiological assessment could be identified; the interpretation of sellar contents in postoperative MRI of group A succeeded earlier and more reliably than in other groups with intrasellar packing. There is no difference in the incidence of postoperative CSF leakage and empty sella syndrome among the various reconstructive techniques with and without intrasellar packing, irrespective of size and extension of the pituitary adenoma. Sellar reconstruction without intrasellar packing following a standard EETS is not inferior to other techniques with packing and even shows more radiological advantages, which made it our preferred technique, at least if no intraoperative CSF leakage is evident.
Van Hecke, Wim; Sijbers, Jan; De Backer, Steve; Poot, Dirk; Parizel, Paul M; Leemans, Alexander
2009-07-01
Although many studies are starting to use voxel-based analysis (VBA) methods to compare diffusion tensor images between healthy and diseased subjects, it has been demonstrated that VBA results depend heavily on parameter settings and implementation strategies, such as the applied coregistration technique, smoothing kernel width, statistical analysis, etc. In order to investigate the effect of different parameter settings and implementations on the accuracy and precision of the VBA results quantitatively, ground truth knowledge regarding the underlying microstructural alterations is required. To address the lack of such a gold standard, simulated diffusion tensor data sets are developed, which can model an array of anomalies in the diffusion properties of a predefined location. These data sets can be employed to evaluate the numerous parameters that characterize the pipeline of a VBA algorithm and to compare the accuracy, precision, and reproducibility of different post-processing approaches quantitatively. We are convinced that the use of these simulated data sets can improve the understanding of how different diffusion tensor image post-processing techniques affect the outcome of VBA. In turn, this may possibly lead to a more standardized and reliable evaluation of diffusion tensor data sets of large study groups with a wide range of white matter altering pathologies. The simulated DTI data sets will be made available online (http://www.dti.ua.ac.be).
Dalpizzol, Mariana; Weber, Magda B; Mattiazzi, Anna Paula F; Manzoni, Ana Paula D
2016-03-01
Many therapies involving varying degrees of complexity have been used to treat acne scars, but none is considered the gold standard treatment. A comparative evaluation of 88% phenol and 90% trichloroacetic acid (TCA) applied using the chemical reconstruction of skin scars (CROSS) technique. A nonrandomized, single-blinded self-controlled clinical trial was conducted among patients with ice pick-type and boxcar-type atrophic acne scars. Using 88% phenol on the left hemiface and 90% TCA on the right hemiface was adopted as the standard practice of the CROSS technique. The dermatological quality of life index (DLQI) questionnaire, acne scar grading scale Échelle d´Evaluation Clinique des Cicatrices d'Acne (ECCA), and evaluation of improvement were performed pretreatment and post-treatment. Regarding ECCA, significant differences were found in pretreatment and post-treatment (p < .001). Regarding tolerance to pain, it was found that the discomfort felt with 90% TCA was significantly less than that felt with 88% phenol (p = .020). Regarding the quality of life measured with the DLQI, the results showed that the mean score in post-treatment assessment was significantly lower than that in the pretreatment assessment (p < .05). Hypochromia and enlargement scar were only seen after the use of 90% TCA. This study confirmed the efficacy of both TCA and phenol for treating such scars, with less severe complications from the use of phenol.
Yu, Xue; Lee, Elaine Yuen Phin; Lai, Vincent; Chan, Queenie
2014-07-01
To evaluate the correlation between standardized uptake value (SUV) (tissue metabolism) and apparent diffusion coefficient (ADC) (water diffusivity) in peritoneal metastases. Patients with peritoneal dissemination detected on (18)F-fluorodeoxyglucose positron emission tomography combined with computed tomography (FDG-PET/CT) were prospectively recruited for MRI examinations with informed consent and the study was approved by the local Institutional Review Board. FDG-PET/CT, diffusion-weighted imaging (DWI), MRI, and DWI/MRI images were independently reviewed by two radiologists based on visual analysis. SUVmax/SUVmean and ADCmin/ADCmean were obtained manually by drawing ROIs over the peritoneal metastases on FDG-PET/CT and DWI, respectively. Diagnostic characteristics of each technique were evaluated. Pearson's coefficient and McNemar and Kappa tests were used for statistical analysis. Eight patients were recruited for this prospective study and 34 peritoneal metastases were evaluated. ADCmean was significantly and negatively correlated with SUVmax (r = -0.528, P = 0.001) and SUVmean (r = -0.548, P = 0.001). ADCmin had similar correlation with SUVmax (r = -0.508, P = 0.002) and SUVmean (r = -0.513, P = 0.002). DWI/MRI had high diagnostic performance (accuracy = 98%) comparable to FDG-PET/CT, in peritoneal metastasis detection. Kappa values were excellent for all techniques. There was a significant inverse correlation between SUV and ADC. © 2013 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tatum, J.L.; Strash, A.M.; Sugerman, H.J.
Using a canine oleic acid model, a computerized gamma scintigraphic technique was evaluated to determine 1) ability to detect pulmonary capillary protein leak in a model temporally consistent with clinical adult respiratory distress syndrome (ARDS), 2) the possibility of providing a quantitative index of leak, and 3) the feasibility of closely spaced repeat evaluations. Study animals received oleic acid (controls, n . 10; 0.05 ml/kg, n . 10; 0.10 ml/kg, n . 12; 0.15 ml/kg, n . 6) 3 hours prior to a tracer dose of technetium-99m (/sup 99/mTc) HSA. One animal in each dose group also received two repeatmore » tracer injections spaced a minimum of 45 minutes apart. Digital images were obtained with a conventional gamma camera interfaced to a dedicated medical computer. Lung: heart ratio versus time curves were generated, and a slope index was calculated for each curve. Slope index values for all doses were significantly greater than control values (P(t) less than 0.0001). Each incremental dose increase was also significantly greater than the previous dose level. Oleic acid dose versus slope index fitted a linear regression model with r . 0.94. Repeat dosing produced index values with standard deviations less than the group sample standard deviations. We feel this technique may have application in the clinical study of pulmonary permeability edema.« less
Jacobson, Magdalena; Wallgren, Per; Nordengrahn, Ann; Merza, Malik; Emanuelson, Ulf
2011-04-01
Lawsonia intracellularis is a common cause of chronic diarrhoea and poor performance in young growing pigs. Diagnosis of this obligate intracellular bacterium is based on the demonstration of the microbe or microbial DNA in tissue specimens or faecal samples, or the demonstration of L. intracellularis-specific antibodies in sera. The aim of the present study was to evaluate a blocking ELISA in the detection of serum antibodies to L. intracellularis, by comparison to the previously widely used immunofluorescent antibody test (IFAT). Sera were collected from 176 pigs aged 8-12 weeks originating from 24 herds with or without problems with diarrhoea and poor performance in young growing pigs. Sera were analyzed by the blocking ELISA and by IFAT. Bayesian modelling techniques were used to account for the absence of a gold standard test and the results of the blocking ELISA was modelled against the IFAT test with a "2 dependent tests, 2 populations, no gold standard" model. At the finally selected cut-off value of percent inhibition (PI) 35, the diagnostic sensitivity of the blocking ELISA was 72% and the diagnostic specificity was 93%. The positive predictive value was 0.82 and the negative predictive value was 0.89, at the observed prevalence of 33.5%. The sensitivity and specificity as evaluated by Bayesian statistic techniques differed from that previously reported. Properties of diagnostic tests may well vary between countries, laboratories and among populations of animals. In the absence of a true gold standard, the importance of validating new methods by appropriate statistical methods and with respect to the target population must be emphasized.
Hyatt, M.W.; Hubert, W.A.
2001-01-01
We developed a standard-weight (Ws) equation for brown trout (Salmo trutta) in lentic habitats by applying the regression-line-percentile technique to samples from 49 populations in North America. The proposed Ws equation is log10 Ws = -5.422 + 3.194 log10 TL, when Ws is in grams and TL is total length in millimeters. The English-unit equivalent is log10 Ws = -3.592 + 3.194 log10 TL, when Ws is in pounds and TL is total length in inches. The equation is applicable for fish of 140-750 mm TL. Proposed length-category standards to evaluate fish within populations are: stock, 200 mm (8 in); quality, 300 mm (12 in); preferred, 400 mm (16 in); memorable, 500 mm (20 in); and trophy, 600 mm (24 in).
Incorporating principal component analysis into air quality ...
The efficacy of standard air quality model evaluation techniques is becoming compromised as the simulation periods continue to lengthen in response to ever increasing computing capacity. Accordingly, the purpose of this paper is to demonstrate a statistical approach called Principal Component Analysis (PCA) with the intent of motivating its use by the evaluation community. One of the main objectives of PCA is to identify, through data reduction, the recurring and independent modes of variations (or signals) within a very large dataset, thereby summarizing the essential information of that dataset so that meaningful and descriptive conclusions can be made. In this demonstration, PCA is applied to a simple evaluation metric – the model bias associated with EPA's Community Multi-scale Air Quality (CMAQ) model when compared to weekly observations of sulfate (SO42−) and ammonium (NH4+) ambient air concentrations measured by the Clean Air Status and Trends Network (CASTNet). The advantages of using this technique are demonstrated as it identifies strong and systematic patterns of CMAQ model bias across a myriad of spatial and temporal scales that are neither constrained to geopolitical boundaries nor monthly/seasonal time periods (a limitation of many current studies). The technique also identifies locations (station–grid cell pairs) that are used as indicators for a more thorough diagnostic evaluation thereby hastening and facilitating understanding of the prob
Jungmann, Pia M.; Baum, Thomas; Bauer, Jan S.; Karampinos, Dimitrios C.; Link, Thomas M.; Li, Xiaojuan; Trattnig, Siegfried; Rummeny, Ernst J.; Woertler, Klaus; Welsch, Goetz H.
2014-01-01
Background. New quantitative magnetic resonance imaging (MRI) techniques are increasingly applied as outcome measures after cartilage repair. Objective. To review the current literature on the use of quantitative MRI biomarkers for evaluation of cartilage repair at the knee and ankle. Methods. Using PubMed literature research, studies on biochemical, quantitative MR imaging of cartilage repair were identified and reviewed. Results. Quantitative MR biomarkers detect early degeneration of articular cartilage, mainly represented by an increasing water content, collagen disruption, and proteoglycan loss. Recently, feasibility of biochemical MR imaging of cartilage repair tissue and surrounding cartilage was demonstrated. Ultrastructural properties of the tissue after different repair procedures resulted in differences in imaging characteristics. T2 mapping, T1rho mapping, delayed gadolinium-enhanced MRI of cartilage (dGEMRIC), and diffusion weighted imaging (DWI) are applicable on most clinical 1.5 T and 3 T MR scanners. Currently, a standard of reference is difficult to define and knowledge is limited concerning correlation of clinical and MR findings. The lack of histological correlations complicates the identification of the exact tissue composition. Conclusions. A multimodal approach combining several quantitative MRI techniques in addition to morphological and clinical evaluation might be promising. Further investigations are required to demonstrate the potential for outcome evaluation after cartilage repair. PMID:24877139
Verification of intravenous catheter placement by auscultation--a simple, noninvasive technique.
Lehavi, Amit; Rudich, Utay; Schechtman, Moshe; Katz, Yeshayahu Shai
2014-01-01
Verification of proper placement of an intravenous catheter may not always be simple. We evaluated the auscultation technique for this purpose. Twenty healthy volunteers were randomized for 18G catheter inserted intravenously either in the right (12) or left arm (8), and subcutaneously in the opposite arm. A standard stethoscope was placed over an area approximately 3 cm proximal to the tip of the catheter in the presumed direction of the vein to grade on a 0-6 scale the murmur heard by rapidly injecting 2 mL of NaCl 0.9% solution. The auscultation was evaluated by a blinded staff anesthesiologist. All 20 intravenous injection were evaluated as flow murmurs, and were graded an average 5.65 (±0.98), whereas all 20 subcutaneous injections were evaluated as either crackles or no sound, and were graded an average 2.00 (±1.38), without negative results. Sensitivity was calculated as 95%. Specificity and Kappa could not be calculated due to an empty false-positive group. Being simple, handy and noninvasive, we recommend to use the auscultation technique for verification of the proper placement of an intravenous catheter when uncertain of its position. Data obtained in our limited sample of healthy subjects need to be confirmed in the clinical setting.
Evaluating the effectiveness of case method instruction in technical communication
NASA Technical Reports Server (NTRS)
Feinberg, S. G.
1981-01-01
The effectiveness of the case method as an instructional technique in improving technical writing was evaluated. The development of a self-report instrument that attempts to measure changes in attitude toward technical communication and the presentation results change are the purpose of this paper. Standards for developing a case set forth by Goldstein and Couture, were used to design an evaluation instrument to measure the effect instruction on student attitude toward technical communication. This self-report instrument is based on model developed and tested by Daly and Miller who studied writer attitude and apprehension toward writing. It was the most important objective of any evaluation is to provide information for improving the program.
Intraoperative fluoroscopic evaluation of screw placement during pelvic and acetabular surgery.
Yi, Chengla; Burns, Sean; Hak, David J
2014-01-01
The surgical treatment of pelvic and acetabular fractures can be technically challenging. Various techniques are available for the reconstruction of pelvic and acetabular fractures. Less invasive percutaneous fracture stabilization techniques, with closed reduction or limited open reduction, have been developed and are gaining popularity in the management of pelvic and acetabular fractures. These techniques require knowledge and interpretation of various fluoroscopic images to ensure appropriate and safe screw placement. Given the anatomic complexity of the intrapelvic structures and the 2-dimensional nature of standard fluoroscopy, multiple images oriented in different planes are needed to assess the accuracy of guide wire and screw placement. This article reviews the fluoroscopic imaging of common screw orientations during pelvic and acetabular surgery.
Spin formalism and applications to new physics searches
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haber, H.E.
1994-12-01
An introduction to spin techniques in particle physics is given. Among the topics covered are: helicity formalism and its applications to the decay and scattering of spin-1/2 and spin-1 particles, techniques for evaluating helicity amplitudes (including projection operator methods and the spinor helicity method), and density matrix techniques. The utility of polarization and spin correlations for untangling new physics beyond the Standard Model at future colliders such as the LHC and a high energy e{sup +}e{sup {minus}} linear collider is then considered. A number of detailed examples are explored including the search for low-energy supersymmetry, a non-minimal Higgs boson sector,more » and new gauge bosons beyond the W{sup {+-}} and Z.« less
Martin, F N; Coffey, M D; Zeller, K; Hamelin, R C; Tooley, P; Garbelotto, M; Hughes, K J D; Kubisiak, T; Bilodeau, G J; Levy, L; Blomquist, C; Berger, P H
2009-04-01
Given the importance of Phytophthora ramorum from a regulatory standpoint, it is imperative that molecular markers for pathogen detection are fully tested to evaluate their specificity in detection of the pathogen. In an effort to evaluate 11 reported diagnostic techniques, we assembled a standardized DNA library using accessions from the World Phytophthora Genetic Resource Collection for 315 isolates representing 60 described Phytophthora spp. as well as 11 taxonomically unclassified isolates. These were sent blind to collaborators in seven laboratories to evaluate published diagnostic procedures using conventional (based on internal transcribed spacer [ITS] and cytochrome oxidase gene [cox]1 and 2 spacer regions) and real-time polymerase chain reaction (based on ITS and cox1 and 2 spacer regions as well as beta-tubulin and elicitin genes). Single-strand conformation polymorphism (SSCP) analysis using an automated sequencer for data collection was also evaluated for identification of all species tested. In general, the procedures worked well, with varying levels of specificity observed among the different techniques. With few exceptions, all assays correctly identified all isolates of P. ramorum and low levels of false positives were observed for the mitochondrial cox spacer markers and most of the real-time assays based on nuclear markers (diagnostic specificity between 96.9 and 100%). The highest level of false positives was obtained with the conventional nested ITS procedure; however, this technique is not stand-alone and is used in conjunction with two other assays for diagnostic purposes. The results indicated that using multiple assays improved the accuracy of the results compared with looking at a single assay alone, in particular when the markers represented different genetic loci. The SSCP procedure accurately identified P. ramorum and was helpful in classification of a number of isolates to a species level. With one exception, all procedures accurately identified P. ramorum in blind evaluations of 60 field samples that included examples of plant infection by 11 other Phytophthora spp. The SSCP analysis identified eight of these species, with three identified to a species group.
Investigating electrical resonance in eddy-current array probes
NASA Astrophysics Data System (ADS)
Hughes, R.; Fan, Y.; Dixon, S.
2016-02-01
The sensitivity enhancing effects of eddy-current testing at frequencies close to electrical resonance are explored. Var-ied techniques exploiting the phenomenon, dubbed near electrical resonance signal enhancement (NERSE), were experimentally investigated to evaluate its potential exploitation for other interesting applications in aerospace materials, in particular its potential for boosting the sensitivity of standard ECT measurements. Methods for setting and controlling the typically unstable resonant frequencies of such systems are discussed. This research is funded by the EPSRC, via the Research Centre for Non-Destructive Evaluation RCNDE, and Rolls-Royce plc.
Keldysh formalism for multiple parallel worlds
NASA Astrophysics Data System (ADS)
Ansari, M.; Nazarov, Y. V.
2016-03-01
We present a compact and self-contained review of the recently developed Keldysh formalism for multiple parallel worlds. The formalism has been applied to consistent quantum evaluation of the flows of informational quantities, in particular, to the evaluation of Renyi and Shannon entropy flows. We start with the formulation of the standard and extended Keldysh techniques in a single world in a form convenient for our presentation. We explain the use of Keldysh contours encompassing multiple parallel worlds. In the end, we briefly summarize the concrete results obtained with the method.
Field evaluation of ventilation system performance in enclosed parking garages
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ayari, A.M.; Grot, D.A.; Krarti, M.
2000-07-01
This paper summarizes the results of a field study to determine the ventilation requirements and the contaminant levels in existing enclosed parking garages. The testing was conducted in seven parking garages with different sizes, traffic flow patterns, vehicle types, and locations. In particular, the study compares the actual ventilation rates measured using the tracer gas technique with the ventilation requirements of ANSI/ASHRAE Standard 62-1989. In addition, the field test evaluated the effectiveness of the existing ventilation systems in maintaining acceptable contaminant levels within enclosed parking garages.
Keldysh formalism for multiple parallel worlds
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ansari, M.; Nazarov, Y. V., E-mail: y.v.nazarov@tudelft.nl
We present a compact and self-contained review of the recently developed Keldysh formalism for multiple parallel worlds. The formalism has been applied to consistent quantum evaluation of the flows of informational quantities, in particular, to the evaluation of Renyi and Shannon entropy flows. We start with the formulation of the standard and extended Keldysh techniques in a single world in a form convenient for our presentation. We explain the use of Keldysh contours encompassing multiple parallel worlds. In the end, we briefly summarize the concrete results obtained with the method.
Larson, S.J.; Capel, P.D.; VanderLoop, A.G.
1996-01-01
Laboratory and quality assurance procedures for the analysis of ground-water samples for herbicides at the Management Systems Evaluation Area near Princeton, Minnesota are described. The target herbicides include atrazine, de-ethylatrazine, de-isopropylatrazine, metribuzin, alachlor, 2,6-diethylaniline, and metolachlor. The analytical techniques used are solid-phase extraction, and analysis by gas chromatography with mass-selective detection. Descriptions of cleaning procedures, preparation of standard solutions, isolation of analytes from water, sample transfer methods, instrumental analysis, and data analysis are included.
Microphotographs of cyanobacteria documenting the effects of various cell-lysis techniques
Rosen, Barry H.; Loftin, Keith A.; Smith, Christopher E.; Lane, Rachael F.; Keydel, Susan P.
2011-01-01
Cyanotoxins are a group of organic compounds biosynthesized intracellularly by many species of cyanobacteria found in surface water. The United States Environmental Protection Agency has listed cyanotoxins on the Safe Drinking Water Act's Contaminant Candidate List 3 for consideration for future regulation to protect public health. Cyanotoxins also pose a risk to humans and other organisms in a variety of other exposure scenarios. Accurate and precise analytical measurements of cyanotoxins are critical to the evaluation of concentrations in surface water to address the human health and ecosystem effects. A common approach to total cyanotoxin measurement involves cell membrane disruption to release the cyanotoxins to the dissolved phase followed by filtration to remove cellular debris. Several methods have been used historically, however no standard protocols exist to ensure this process is consistent between laboratories before the dissolved phase is measured by an analytical technique for cyanotoxin identification and quantitation. No systematic evaluation has been conducted comparing the multiple laboratory sample processing techniques for physical disruption of cell membrane or cyanotoxins recovery. Surface water samples collected from lakes, reservoirs, and rivers containing mixed assemblages of organisms dominated by cyanobacteria, as well as laboratory cultures of species-specific cyanobacteria, were used as part of this study evaluating multiple laboratory cell-lysis techniques in partnership with the U.S. Environmental Protection Agency. Evaluated extraction techniques included boiling, autoclaving, sonication, chemical treatment, and freeze-thaw. Both treated and untreated samples were evaluated for cell membrane integrity microscopically via light, epifluorescence, and epifluorescence in the presence of a DNA stain. The DNA stain, which does not permeate live cells with intact membrane structures, was used as an indicator for cyanotoxin release into the dissolved phase. Of the five techniques, sonication (at 70 percent) was most effective at complete cell destruction while QuikLyse (Trademarked) was least effective. Autoclaving, boiling, and sequential freeze-thaw were moderately effective in physical destruction of colonies and filaments.
TOKYO criteria 2014 for transpapillary biliary stenting.
Isayama, Hiroyuki; Hamada, Tsuyoshi; Yasuda, Ichiro; Itoi, Takao; Ryozawa, Shomei; Nakai, Yousuke; Kogure, Hirofumi; Koike, Kazuhiko
2015-01-01
It is difficult to carry out meta-analyses or to compare the results of different studies of biliary stents because there is no uniform evaluation method. Therefore, a standardized reporting system is required. We propose a new standardized system for reporting on biliary stents, the 'TOKYO criteria 2014', based on a consensus among Japanese pancreatobiliary endoscopists. Instead of stent occlusion, we use recurrent biliary obstruction, which includes occlusion and migration. The time to recurrent biliary obstruction was estimated using Kaplan-Meier analysis with the log-rank test. We can evaluate both plastic and self-expandable metallic stents (uncovered and covered). We also propose specification of the cause of recurrent biliary obstruction, identification of complications other than recurrent biliary obstruction, indication of severity, measures of technical and clinical success, and a standard for clinical care. Most importantly, the TOKYO criteria 2014 allow comparison of biliary stent quality across studies. Because blocked stents can be drained not only using transpapillary techniques but also by an endoscopic ultrasonography-guided transmural procedure, we should devise an evaluation method that includes transmural stenting in the near future. © 2014 The Authors. Digestive Endoscopy © 2014 Japan Gastroenterological Endoscopy Society.
Evaluative procedures to detect, characterize, and assess the severity of diabetic neuropathy.
Dyck, P J
1991-01-01
Minimal criteria for diabetic neuropathy need to be defined and universally applied. Standardized evaluative procedures need to be agreed and normal ranges determined from healthy volunteers. Types and stages of neuropathy should be established and assessments performed on representative populations of both Type 1 and Type 2 diabetic patients. Potential minimal criteria include absent ankle reflexes and vibratory sensation, and abnormalities of nerve conduction. However, the preferred criterion is the identification of more than two statistically defined abnormalities among symptoms and deficits, nerve conduction, quantitative sensory examination or quantitative autonomic examination. Various evaluative procedures are available. Symptoms should be assessed and scores can be assigned to neurological deficits. However, assessments of nerve conduction provide the most specific, objective, sensitive, and repeatable procedures, although these may be the least meaningful. Many techniques are available for quantitative sensory examination, but are poorly standardized and normal values are not available. For quantitative autonomic examination, tests are available for the adequacy of cardiovascular and peripheral vascular reflexes and increasingly for other autonomic functions. In any assessment of nerve function the conditions should be optimized and standardized, and stimuli defined. Specific instructions should be given and normal ranges established in healthy volunteers.
NASA Technical Reports Server (NTRS)
Lysak, Daniel B.
2003-01-01
The applicability of shearography techniques for non-destructive evaluation in two unique application areas is examined. In the first application, shearography is used to evaluate the quality of adhesive bonds holding lead tiles to the B.4T gamma ray mask for the NASA Swift program. Using a vibration excitation, the more poorly bonded tiles are readily identifiable in the shearography image. A quantitative analysis is presented that compares the shearography results with a destructive pull test measuring the force at bond failure. The second application is to evaluate the bonding between the skin and core of a honeycomb structure with a specular (mirror-like) surface. In standard shearography techniques, the object under test must have a diffuse surface to generate the speckle patterns in laser light, which are then sheared. A novel configuration using the specular surface as a mirror to image speckles from a diffuser is presented, opening up the use of shearography to a new class of objects that could not have been examined with the traditional approach. This new technique readily identifies large scale bond failures in the panel, demonstrating the validity of this approach.
Performance evaluation of a digital mammography unit using a contrast-detail phantom
NASA Astrophysics Data System (ADS)
Elizalde-Cabrera, J.; Brandan, M.-E.
2015-01-01
The relation between image quality and mean glandular dose (MGD) has been studied for a Senographe 2000D mammographic unit used for research in our laboratory. The magnitudes were evaluated for a clinically relevant range of acrylic thicknesses and radiological techniques. The CDMAM phantom was used to determine the contrast-detail curve. Also, an alternative method based on the analysis of signal-to-noise (SNR) and contrast-to-noise (CNR) ratios from the CDMAM image was proposed and applied. A simple numerical model was utilized to successfully interpret the results. Optimum radiological techniques were determined using the figures-of-merit FOMSNR=SNR2/MGD and FOMCNR=CNR2/MGD. Main results were: the evaluation of the detector response flattening process (it reduces by about one half the spatial non-homogeneities due to the X- ray field), MGD measurements (the values comply with standards), and verification of the automatic exposure control performance (it is sensitive to fluence attenuation, not to contrast). For 4-5 cm phantom thicknesses, the optimum radiological techniques were Rh/Rh 34 kV to optimize SNR, and Rh/Rh 28 kV to optimize CNR.
Thomas, Karluss; Herouet-Guicheney, Corinne; Ladics, Gregory; McClain, Scott; MacIntosh, Susan; Privalle, Laura; Woolhiser, Mike
2008-09-01
The International Life Science Institute's Health and Environmental Sciences Institute's Protein Allergenicity Technical Committee hosted an international workshop October 23-25, 2007, in Nice, France, to review and discuss existing and emerging methods and techniques for improving the current weight-of-evidence approach for evaluating the potential allergenicity of novel proteins. The workshop included over 40 international experts from government, industry, and academia. Their expertise represented a range of disciplines including immunology, chemistry, molecular biology, bioinformatics, and toxicology. Among participants, there was consensus that (1) current bioinformatic approaches are highly conservative; (2) advances in bioinformatics using structural comparisons of proteins may be helpful as the availability of structural data increases; (3) proteomics may prove useful for monitoring the natural variability in a plant's proteome and assessing the impact of biotechnology transformations on endogenous levels of allergens, but only when analytical techniques have been standardized and additional data are available on the natural variation of protein expression in non-transgenic bred plants; (4) basophil response assays are promising techniques, but need additional evaluation around specificity, sensitivity, and reproducibility; (5) additional research is required to develop and validate an animal model for the purpose of predicting protein allergenicity.
de Carvalho, Rogério Mendonca; Perez, Maria Del Carmen Janerio; Miranda, Fausto
2012-10-01
Traditional volumetry based on Archimedes' principle is the gold standard for the measurement of limb volume, but the routine use of this technique is discouraged because of several disadvantages. The purpose of this study was to evaluate intraobserver and interobserver reliability of direct measurements of wrist-hand volume using a new communicating vessels volumeter based on Pascal's law. A reliability study was conducted. To evaluate the reliability of the communicating vessels volumeter in generating measurements, 30 hands of 15 participants (9 women, 6 men) were measured 3 times each by 3 observers, totaling 270 volumetric results. Measurement time was short (X =3 minutes 42 seconds). The intraclass correlation coefficient (ICC) was .9977 for observer 1 and .9976 for observers 2 and 3. The interobserver ICC was .9998. The standard error of measurement was about 3 mL for all observers; the interobserver result was 1 mL. The interrater coefficient of variance (CV) was 1.15% for the series of 9 measurements collected for each segment; the intrarater CV was 1.20%. Limitations No swollen hands were measured, and measurements were not compared with the gold standard technique. Thus, accuracy of the new volumeter was not determined in this study. A new device has been developed for plethysmography of the extremities, and the results of its use to measure the volume of the wrist-hand segment were reliable in both intraobserver and interobserver analyses.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1983-02-01
Work on energy consumption in a large office building is reported, including the following tasks: (1) evaluating and testing the effectiveness of the existing ASHRAE 90-75 and 90-80 standards; (2) evaluating the effectiveness of the BEPS; (3) evaluating the effectiveness of some envelope and lighting design variables towards achieving the BEPS budgets; and (4) comparing the computer energy analysis technique, DOE-2.1, with manual calculation procedures. These tasks are the initial activities in the energy analysis of the Park Plaza Building and will serve as the basis for further understanding the results of ongoing data collection and analysis.
Akhlaq, Muhammad; Khan, Gul Majid; Jan, Syed Umer; Wahab, Abdul; Hussain, Abid; Nawaz, Asif; Abdelkader, Hamdy
2014-11-01
Diclofenac sodium (DCL-Na) conventional oral tablets exhibit serious side effects when given for a longer period leading to noncompliance. Controlled release matrix tablets of diclofenac sodium were formulated using simple blending (F-1), solvent evaporation (F-2) and co-precipitation techniques (F-3). Ethocel® Standard 7 FP Premium Polymer (15%) was used as a release controlling agent. Drug release study was conducted in 7.4 pH phosphate buffer solutions as dissolution medium in vitro. Pharmacokinetic parameters were evaluated using albino rabbits. Solvent evaporation technique was found to be the best release controlling technique thereby prolonging the release rate up to 24 hours. Accelerated stability studies of the optimized test formulation (F-2) did not show any significant change (p<0.05) in the physicochemical characteristics and release rate when stored for six months. A simple and rapid method was developed for DCL-Na active moiety using HPLC-UV at 276nm. The optimized test tablets (F-2) significantly (p<0.05) exhibited peaks plasma concentration (cmax=237.66±1.98) and extended the peak time (tmax=4.63±0.24). Good in-vitro in vivo correlation was found (R(2)=0.9883) against drug absorption and drug release. The study showed that once-daily controlled release matrix tablets of DCL-Na were successfully developed using Ethocel® Standard 7 FP Premium.
Davis, Matthew L; Scott Gayzik, F
2016-10-01
Biofidelity response corridors developed from post-mortem human subjects are commonly used in the design and validation of anthropomorphic test devices and computational human body models (HBMs). Typically, corridors are derived from a diverse pool of biomechanical data and later normalized to a target body habitus. The objective of this study was to use morphed computational HBMs to compare the ability of various scaling techniques to scale response data from a reference to a target anthropometry. HBMs are ideally suited for this type of study since they uphold the assumptions of equal density and modulus that are implicit in scaling method development. In total, six scaling procedures were evaluated, four from the literature (equal-stress equal-velocity, ESEV, and three variations of impulse momentum) and two which are introduced in the paper (ESEV using a ratio of effective masses, ESEV-EffMass, and a kinetic energy approach). In total, 24 simulations were performed, representing both pendulum and full body impacts for three representative HBMs. These simulations were quantitatively compared using the International Organization for Standardization (ISO) ISO-TS18571 standard. Based on these results, ESEV-EffMass achieved the highest overall similarity score (indicating that it is most proficient at scaling a reference response to a target). Additionally, ESEV was found to perform poorly for two degree-of-freedom (DOF) systems. However, the results also indicated that no single technique was clearly the most appropriate for all scenarios.
A new technique for quantitative analysis of hair loss in mice using grayscale analysis.
Ponnapakkam, Tulasi; Katikaneni, Ranjitha; Gulati, Rohan; Gensure, Robert
2015-03-09
Alopecia is a common form of hair loss which can occur in many different conditions, including male-pattern hair loss, polycystic ovarian syndrome, and alopecia areata. Alopecia can also occur as a side effect of chemotherapy in cancer patients. In this study, our goal was to develop a consistent and reliable method to quantify hair loss in mice, which will allow investigators to accurately assess and compare new therapeutic approaches for these various forms of alopecia. The method utilizes a standard gel imager to obtain and process images of mice, measuring the light absorption, which occurs in rough proportion to the amount of black (or gray) hair on the mouse. Data that has been quantified in this fashion can then be analyzed using standard statistical techniques (i.e., ANOVA, T-test). This methodology was tested in mouse models of chemotherapy-induced alopecia, alopecia areata and alopecia from waxing. In this report, the detailed protocol is presented for performing these measurements, including validation data from C57BL/6 and C3H/HeJ strains of mice. This new technique offers a number of advantages, including relative simplicity of application, reliance on equipment which is readily available in most research laboratories, and applying an objective, quantitative assessment which is more robust than subjective evaluations. Improvements in quantification of hair growth in mice will improve study of alopecia models and facilitate evaluation of promising new therapies in preclinical studies.
Cosmographic analysis with Chebyshev polynomials
NASA Astrophysics Data System (ADS)
Capozziello, Salvatore; D'Agostino, Rocco; Luongo, Orlando
2018-05-01
The limits of standard cosmography are here revised addressing the problem of error propagation during statistical analyses. To do so, we propose the use of Chebyshev polynomials to parametrize cosmic distances. In particular, we demonstrate that building up rational Chebyshev polynomials significantly reduces error propagations with respect to standard Taylor series. This technique provides unbiased estimations of the cosmographic parameters and performs significatively better than previous numerical approximations. To figure this out, we compare rational Chebyshev polynomials with Padé series. In addition, we theoretically evaluate the convergence radius of (1,1) Chebyshev rational polynomial and we compare it with the convergence radii of Taylor and Padé approximations. We thus focus on regions in which convergence of Chebyshev rational functions is better than standard approaches. With this recipe, as high-redshift data are employed, rational Chebyshev polynomials remain highly stable and enable one to derive highly accurate analytical approximations of Hubble's rate in terms of the cosmographic series. Finally, we check our theoretical predictions by setting bounds on cosmographic parameters through Monte Carlo integration techniques, based on the Metropolis-Hastings algorithm. We apply our technique to high-redshift cosmic data, using the Joint Light-curve Analysis supernovae sample and the most recent versions of Hubble parameter and baryon acoustic oscillation measurements. We find that cosmography with Taylor series fails to be predictive with the aforementioned data sets, while turns out to be much more stable using the Chebyshev approach.
Wavelet-Bayesian inference of cosmic strings embedded in the cosmic microwave background
NASA Astrophysics Data System (ADS)
McEwen, J. D.; Feeney, S. M.; Peiris, H. V.; Wiaux, Y.; Ringeval, C.; Bouchet, F. R.
2017-12-01
Cosmic strings are a well-motivated extension to the standard cosmological model and could induce a subdominant component in the anisotropies of the cosmic microwave background (CMB), in addition to the standard inflationary component. The detection of strings, while observationally challenging, would provide a direct probe of physics at very high-energy scales. We develop a framework for cosmic string inference from observations of the CMB made over the celestial sphere, performing a Bayesian analysis in wavelet space where the string-induced CMB component has distinct statistical properties to the standard inflationary component. Our wavelet-Bayesian framework provides a principled approach to compute the posterior distribution of the string tension Gμ and the Bayesian evidence ratio comparing the string model to the standard inflationary model. Furthermore, we present a technique to recover an estimate of any string-induced CMB map embedded in observational data. Using Planck-like simulations, we demonstrate the application of our framework and evaluate its performance. The method is sensitive to Gμ ∼ 5 × 10-7 for Nambu-Goto string simulations that include an integrated Sachs-Wolfe contribution only and do not include any recombination effects, before any parameters of the analysis are optimized. The sensitivity of the method compares favourably with other techniques applied to the same simulations.
Barillari, Maria Rosaria; Volpe, Umberto; Mirra, Giuseppina; Giugliano, Francesco; Barillari, Umberto
2017-05-01
Phonomicrosurgery is generally considered to be the treatment of choice for removing vocal fold polyps. However, specific techniques of voice therapy may represent, in selected cases and under certain conditions, a noninvasive therapeutic option for the treatment of such laryngeal lesions. The aim of the present study is to longitudinally assess, in terms of clinical outcomes and quality of life, two groups of patients with cordal polyps, treated either with standard surgery plus standard voice therapy or with a specific training of voice therapy alone, which we have called "Voice Therapy Expulsion." This study is a randomized controlled trial. A total of 150 patients with vocal fold polyps were randomly assigned to either standard surgery or "voice therapy expulsion" protocol. The trial was carried out at the Division of Phoniatrics and Audiology of the Second University of Naples and at the Division of Communication Disorders of Local Health Unit (3 Naples South) from January 2010 to December 2013. A thorough phoniatric evaluation, including laryngostroboscopy, acoustic voice analysis, global grade of dysphonia, instability, roughness, breathiness, asthenia, and strain scale, Voice Handicap Index, and Voice-Related Quality of Life, was performed by using standardized tools, at baseline, at the end of the treatment, and up to 1 year after treatment. We found no significant differences between the two experimental groups in terms of clinical outcomes and personal satisfaction. However, "Voice Therapy Expulsion" was associated with higher scores for quality of life at endpoint evaluation. Besides phonosurgery, this specific "Voice Therapy Expulsion" technique should be considered as a valid, noninvasive, and well-tolerated therapeutic option for the treatment of selected patients with vocal fold polyps. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Ma, Xiaoyue; Niezgoda, Michael; Blanton, Jesse D; Recuenco, Sergio; Rupprecht, Charles E
2012-08-03
Two major techniques are currently used to estimate rabies virus antibody values: neutralization assays, such as the rapid fluorescent focus inhibition test (RFFIT), and enzyme-linked immunosorbent assays (ELISAs). The RFFIT is considered the gold standard assay and has been used to assess the titer of rabies virus neutralizing antibodies for more than three decades. In the late 1970s, ELISA began to be used to estimate the level of rabies virus antibody and has recently been used by some laboratories as an alternate screening test for animal sera. Although the ELISA appears simpler, safer and more efficient, the assay is less sensitive in detecting low values of rabies virus neutralizing antibodies than neutralization tests. This study was designed to evaluate a new ELISA-based method for detecting rabies virus binding antibody. This new technique uses electro-chemi-luminescence labels and carbon electrode plates to detect binding events. In this comparative study, the RFFIT and the new ELISA-based technique were used to evaluate the level of rabies virus antibodies in human and animal serum samples. By using a conservative approximation of 0.15 IU/ml as a cutoff point, the new ELISA-based technique demonstrated a sensitivity of 100% and a specificity of 95% for human samples and for experimental animal samples. The sensitivity and specificity for field animal samples was 96% and 95%, respectively. The preliminary results from this study appear promising and demonstrate a higher sensitivity than traditional ELISA methods. Published by Elsevier Ltd.
An evaluation of hernia education in surgical residency programs.
Hope, W W; O'Dwyer, B; Adams, A; Hooks, W B; Kotwall, C A; Clancy, T V
2014-08-01
The purpose of this study was to evaluate surgical residents' educational experience related to ventral hernias. A 16-question survey was sent to all program coordinators to distribute to their residents. Consent was obtained following a short introduction of the purpose of the survey. Comparisons based on training level were made using χ(2) test of independence, Fisher's exact, and Fisher's exact with Monte Carlo estimate as appropriate. A p value <0.05 was considered significant. The survey was returned by 183 residents from 250 surgical programs. Resident postgraduate year (PG-Y) level was equivalent among groups. Preferred techniques for open ventral hernia varied; the most common (32 %) was intra-abdominal placement of mesh with defect closure. Twenty-two percent of residents had not heard of the retrorectus technique for hernia repair, 48 % had not performed the operation, and 60 % were somewhat comfortable with and knew the general categories of mesh prosthetics products. Mesh choices, biologic and synthetic, varied among the different products. The most common type of hernia education was teaching in the operating room in 87 %, didactic lecture 69 %, and discussion at journal club 45 %. Number of procedures, comfort level with open and laparoscopic techniques, indications for mesh use and technique, familiarity and use of retrorectus repair, and type of hernia education varied significantly based on resident level (p < 0.05). Exposure to hernia techniques and mesh prosthetics in surgical residency programs appears to vary. Further evaluation is needed and may help in standardizing curriculums for hernia repair for surgical residents.
Curve fitting air sample filter decay curves to estimate transuranic content.
Hayes, Robert B; Chiou, Hung Cheng
2004-01-01
By testing industry standard techniques for radon progeny evaluation on air sample filters, a new technique is developed to evaluate transuranic activity on air filters by curve fitting the decay curves. The industry method modified here is simply the use of filter activity measurements at different times to estimate the air concentrations of radon progeny. The primary modification was to not look for specific radon progeny values but rather transuranic activity. By using a method that will provide reasonably conservative estimates of the transuranic activity present on a filter, some credit for the decay curve shape can then be taken. By carrying out rigorous statistical analysis of the curve fits to over 65 samples having no transuranic activity taken over a 10-mo period, an optimization of the fitting function and quality tests for this purpose was attained.
Right Ventricular Pacing for Assessment of Cavo-Tricuspid Isthmus Block.
Venkataraman, Ganesh; Wish, Marc; Friehling, Ted; Strickberger, S Adam
2016-01-01
Background: Cavo-tricuspid isthmus (CTI) dependent atrial flutter is typically treated with cardiac ablation. Standard techniques to assess CTI block after ablation can be technically challenging. Right ventricular (RV) pacing may allow for another technique to assess CTI block after ablation. Objective: The purpose of this study was to evaluate RV pacing as a method to assess CTI block after ablation of CTI dependent atrial flutter, and define endpoints of ablation using this technique. Methods: 28 patients undergoing ablation of CTI dependent atrial flutter with intact ventriculoatrial (VA) conduction were prospectively enrolled in this study and underwent the RV pacing protocol, as well as standard coronary sinus (CS) pacing techniques to assess CTI block. Results: The mean trans-isthmus conduction interval during CS pacing (TICI CS ) at 600 and 400ms after CTI ablation was 168 +/- 9ms and 175 +/- 18ms, respectively. The mean trans-isthmus conduction interval during RV pacing (TICI RV ) at 600ms and 400ms after CTI ablation was 109 +/- 5ms and 111 +/- 5ms, respectively. A TICI RV >100ms was associated with a successful outcome after CTI ablation. Conclusions: RV pacing may add incremental value in the assessment of CTI block in patients undergoing ablation of CTI dependent atrial flutter.
Trottmann, M; Rübenthaler, J; Marcon, J; Stief, C G; Reiser, M F; Clevert, D A
2016-01-01
To investigate the difference of standard values of Supersonic shear imaging (SSI) and Acoustic Radiation Force Impulse (ARFI) technique in the evaluation of testicular tissue stiffness in vivo. 58 healthy male testes were examined using B-mode sonography and ARFI and SSI. B-mode sonography was performed in order to scan the testis for pathologies followed by performance of real-time elastography in three predefined areas (upper pole, central portion and lower pole) using the SuperSonic® Aixplorer ultrasound device (SuperSonic Imagine, Aix-en-Provence, France). Afterwards a second assessment of the same testicular regions by elastography followed using the ARFI technique of the Siemens Acuson 2000™ ultrasound device (Siemens Health Care, Germany). Values of shear wave velocity were described in m/s. Parameters of elastography techniques were compared using paired sample t-test. The values of SSI were all significantly higher in all measured areas compared to ARFI (p < 0.001 to p = 0.015). Quantitatively there was a higher mean SSI wave velocity value of 1,1 compared to 0.8 m/s measured by ARFI. SSI values are significantly higher than ARFI values when measuring the stiffness of testicular tissue and should only be compared with caution.
Radiation techniques used in patients with breast cancer: Results of a survey in Spain
Algara, Manuel; Arenas, Meritxell; De las Peñas Eloisa Bayo, Dolores; Muñoz, Julia; Carceller, José Antonio; Salinas, Juan; Moreno, Ferran; Martínez, Francisco; González, Ezequiel; Montero, Ángel
2012-01-01
Aim To evaluate the resources and techniques used in the irradiation of patients with breast cancer after lumpectomy or mastectomy and the status of implementation of new techniques and therapeutic schedules in our country. Background The demand for cancer care has increased among the Spanish population, as long as cancer treatment innovations have proliferated. Radiation therapy in breast cancer has evolved exponentially in recent years with the implementation of three-dimensional conformal radiotherapy, intensity modulated radiotherapy, image guided radiotherapy and hypofractionation. Material and Methods An original survey questionnaire was sent to institutions participating in the SEOR-Mama group (GEORM). In total, the standards of practice in 969 patients with breast cancer after surgery were evaluated. Results The response rate was 70% (28/40 centers). In 98.5% of cases 3D conformal treatment was used. All the institutions employed CT-based planning treatment. Boost was performed in 56.4% of patients: electrons in 59.8%, photons in 23.7% and HDR brachytherapy in 8.8%. Fractionation was standard in 93.1% of patients. Supine position was the most frequent. Only 3 centers used prone position. The common organs of risk delimited were: homolateral lung (80.8%) and heart (80.8%). In 84% histograms were used. An 80.8% of the centers used isocentric technique. In 62.5% asymmetric fields were employed. CTV was delimited in 46.2%, PTV in 65% and both in 38.5%. A 65% of the centers checked with portal films. IMRT and hypofractionation were used in 1% and in 5.5% respectively. Conclusion In most of centers, 3D conformal treatment and CT-based planning treatment were used. IMRT and hypofractionation are currently poorly implemented in Spain. PMID:24377012
Campbell, Darren; Carnell, Sarah Maria; Eden, Russell John
2013-05-01
Contact angle, as a representative measure of surface wettability, is often employed to interpret contact lens surface properties. The literature is often contradictory and can lead to confusion. This literature review is part of a series regarding the analysis of hydrogel contact lenses using contact angle techniques. Here we present an overview of contact angle terminology, methodology, and analysis. Having discussed this background material, subsequent parts of the series will discuss the analysis of contact lens contact angles and evaluate differences in published laboratory results. The concepts of contact angle, wettability and wetting are presented as an introduction. Contact angle hysteresis is outlined and highlights the advantages in using dynamic analytical techniques over static methods. The surface free energy of a material illustrates how contact angle analysis is capable of providing supplementary surface characterization. Although single values are able to distinguish individual material differences, surface free energy and dynamic methods provide an improved understanding of material behavior. The frequently used sessile drop, captive bubble, and Wilhelmy plate techniques are discussed. Their use as both dynamic and static methods, along with the advantages and disadvantages of each technique, is explained. No single contact angle technique fully characterizes the wettability of a material surface, and the application of complimenting methods allows increased characterization. At present, there is not an ISO standard method designed for soft materials. It is important that each contact angle technique has a standard protocol, as small protocol differences between laboratories often contribute to a variety of published data that are not easily comparable.
Dyer, Brandon A; Jenshus, Abriel; Mayadev, Jyoti S
2018-02-28
Radiation therapy (RT) plays a definitive role in locally advanced vulvar cancer, and in the adjuvant setting with high risk postoperative features after wide local excision. There is significant morbidity associated with traditional, large RT fields using 2D or 3D techniques, and the use of intensity-modulated radiation therapy (IMRT) in vulvar cancer is increasing. However, there remains a paucity of technical information regarding the prevention of a marginal miss during the treatment planning process. The use of an integrated skin flash (ISF) during RT planning can be used to account for anatomic variation, and intra- and interfraction motion seen during treatment. Herein we present the case of a patient with a T1aN0M0, Stage IA vulva cancer to illustrate the progressive vulvar swelling and lymph edema seen during treatment and retrospectively evaluate the dosimetric effects of using an ISF RT plan vs standard RT planning techniques. Standard planning techniques to treat vulvar cancer patients with IMRT do not sufficiently account for the change in patient anatomy and can lead to a marginal miss. ISF is an RT planning technique that can decrease the risk of a marginal miss and the technique is easily implemented during the planning stages of RT treatment. Furthermore, use of an ISF technique can improve vulvar clinical target volume coverage and plan homogeneity. Based on our experience, and this study, a 2-cm ISF is suggested to account for variations in daily clinical setup and changes in patient anatomy during treatment. Published by Elsevier Inc.
NASA Astrophysics Data System (ADS)
Xia, Yi
Fractures and associated bone fragility induced by osteoporosis and osteopenia are widespread health threat to current society. Early detection of fracture risk associated with bone quantity and quality is important for both the prevention and treatment of osteoporosis and consequent complications. Quantitative ultrasound (QUS) is an engineering technology for monitoring bone quantity and quality of humans on earth and astronauts subjected to long duration microgravity. Factors currently limiting the acceptance of QUS technology involve precision, accuracy, single index and standardization. The objective of this study was to improve the accuracy and precision of an image-based QUS technique for non-invasive evaluation of trabecular bone quantity and quality by developing new techniques and understanding ultrasound/tissue interaction. Several new techniques have been developed in this dissertation study, including the automatic identification of irregular region of interest (iROI) in bone, surface topology mapping (STM) and mean scattering spacing (MSS) estimation for evaluating trabecular bone structure. In vitro results have shown that (1) the inter- and intra-observer errors in QUS measurement were reduced two to five fold by iROI compared to previous results; (2) the accuracy of QUS parameter, e.g., ultrasound velocity (UV) through bone, was improved 16% by STM; and (3) the averaged trabecular spacing can be estimated by MSS technique (r2=0.72, p<0.01). The measurement errors of BUA and UV introduced by the soft tissue and cortical shells in vivo can be quantified by developed foot model and simplified cortical-trabecular-cortical sandwich model, which were verified by the experimental results. The mechanisms of the errors induced by the cortical and soft tissues were revealed by the model. With developed new techniques and understanding of sound-tissue interaction, in vivo clinical trail and bed rest study were preformed to evaluate the performance of QUS in clinical applications. It has been demonstrated that the QUS has similar performance for in vivo bone density measurement compared to current gold-standard method, i.e., DXA, while additional information are obtained by the QUS for predicting fracture risk by monitoring of bone's quality. The developed QUS imaging technique can be used to assess bone's quantity and quality with improved accuracy and precision.
McDonald, Gene D; Storrie-Lombardi, Michael C
2006-02-01
The relative abundance of the protein amino acids has been previously investigated as a potential marker for biogenicity in meteoritic samples. However, these investigations were executed without a quantitative metric to evaluate distribution variations, and they did not account for the possibility of interdisciplinary systematic error arising from inter-laboratory differences in extraction and detection techniques. Principal component analysis (PCA), hierarchical cluster analysis (HCA), and stochastic probabilistic artificial neural networks (ANNs) were used to compare the distributions for nine protein amino acids previously reported for the Murchison carbonaceous chondrite, Mars meteorites (ALH84001, Nakhla, and EETA79001), prebiotic synthesis experiments, and terrestrial biota and sediments. These techniques allowed us (1) to identify a shift in terrestrial amino acid distributions secondary to diagenesis; (2) to detect differences in terrestrial distributions that may be systematic differences between extraction and analysis techniques in biological and geological laboratories; and (3) to determine that distributions in meteoritic samples appear more similar to prebiotic chemistry samples than they do to the terrestrial unaltered or diagenetic samples. Both diagenesis and putative interdisciplinary differences in analysis complicate interpretation of meteoritic amino acid distributions. We propose that the analysis of future samples from such diverse sources as meteoritic influx, sample return missions, and in situ exploration of Mars would be less ambiguous with adoption of standardized assay techniques, systematic inclusion of assay standards, and the use of a quantitative, probabilistic metric. We present here one such metric determined by sequential feature extraction and normalization (PCA), information-driven automated exploration of classification possibilities (HCA), and prediction of classification accuracy (ANNs).
Air Velocity Mapping of Environmental Test Chambers
1989-07-01
variable that must be measured for the evaluations of the air diffusion performance index (ADPI), or the thermal comfort indices such as predicted mean...altered. The impact of asymmetrical airflow patterns undoubtedly affect human thermal comfort votes. The standardized 6 technique described in this...report could be easily employed prior to or along with specific studies requiring precise air velocity data, and coupled with human thermal comfort surveys
Active Control Technique Evaluation for Spacecraft (ACES)
1988-06-16
spare Voyager Astromast built by ASTRO Research, Inc. It was supplied to MSFC by the Jet Propulsion Laboratory (JPL). The Astromast is extremely...assuming full controlled state availability, is u = - FXc . The control law designed via the modified control weighting matrix deserves comment...minimizes J has the form u(k) = - FXc (k) and can be found via standard software for solving the discrete algebraic Riccati
Parrilla, Inma; del Olmo, David; Sijses, Laurien; Martinez-Alborcia, María J; Cuello, Cristina; Vazquez, Juan M; Martinez, Emilio A; Roca, Jordi
2012-05-01
The present study aimed to evaluate the ability of spermatozoa from individual boar ejaculates to withstand different semen-processing techniques. Eighteen sperm-rich ejaculate samples from six boars (three per boar) were diluted in Beltsville Thawing Solution and split into three aliquots. The aliquots were (1) further diluted to 3×10(7) sperm/mL and stored as a liquid at 17°C for 72 h, (2) frozen-thawed (FT) at 1×10(9) sperm/mL using standard 0.5-mL straw protocols, or (3) sex-sorted with subsequent liquid storage (at 17°C for 6 h) or FT (2×10(7) sperm/mL using a standard 0.25-mL straw protocol). The sperm quality was evaluated based on total sperm motility (the CASA system), viability (plasma membrane integrity assessed using flow cytometry and the LIVE/DEAD Sperm Viability Kit), lipid peroxidation (assessed via indirect measurement of the generation of malondialdehyde (MDA) using the BIOXYTECH MDA-586 Assay Kit) and DNA fragmentation (sperm chromatin dispersion assessed using the Sperm-Sus-Halomax(®) test). Data were normalized to the values assessed for the fresh (for liquid-stored and FT samples) or the sorted semen samples (for liquid stored and the FT sorted spermatozoa). All of the four sperm-processing techniques affected sperm quality (P<0.01), regardless of the semen donor, with reduced percentages of motile and viable sperm and increased MDA generation and percentages of sperm with fragmented DNA. Significant (P<0.05) inter-boar (effect of boars within each semen-processing technique) and intra-boar (effect of semen-processing techniques within each boar) differences were evident for all of the sperm quality parameters assessed, indicating differences in the ability of spermatozoa from individual boars to withstand the semen-processing techniques. These results are the first evidence that ejaculate spermatozoa from individual boars can respond in a boar-dependent manner to different semen-processing techniques. Copyright © 2012 Elsevier B.V. All rights reserved.
MRI in patients with inflammatory bowel disease
Gee, Michael S.; Harisinghani, Mukesh G.
2011-01-01
Inflammatory bowel disease (IBD) affects approximately 1.4 million people in North America and, because of its typical early age of onset and episodic disease course, IBD patients often undergo numerous imaging studies over the course of their lifetimes. CT has become the standard imaging modality for assessment of IBD patients because of its widespread availability, rapid image acquisition, and ability to evaluate intraluminal and extraluminal disease. However, repetitive CT imaging has been associated with a significant ionizing radiation risk to patients, making MRI an appealing alternative IBD imaging modality. Pelvic MRI is currently the imaging gold standard for detecting perianal disease, while recent studies indicate that MRI bowel-directed techniques (enteroclysis, enterography, colonography) can accurately evaluate bowel inflammation in IBD. With recent technical innovations leading to faster and higher resolution body MRI, the role of MRI in IBD evaluation is likely to continue to expand. Future applications include surveillance imaging, detection of mural fibrosis, and early assessment of therapy response. PMID:21512607
[Research progress on mechanical performance evaluation of artificial intervertebral disc].
Li, Rui; Wang, Song; Liao, Zhenhua; Liu, Weiqiang
2018-03-01
The mechanical properties of artificial intervertebral disc (AID) are related to long-term reliability of prosthesis. There are three testing methods involved in the mechanical performance evaluation of AID based on different tools: the testing method using mechanical simulator, in vitro specimen testing method and finite element analysis method. In this study, the testing standard, testing equipment and materials of AID were firstly introduced. Then, the present status of AID static mechanical properties test (static axial compression, static axial compression-shear), dynamic mechanical properties test (dynamic axial compression, dynamic axial compression-shear), creep and stress relaxation test, device pushout test, core pushout test, subsidence test, etc. were focused on. The experimental techniques using in vitro specimen testing method and testing results of available artificial discs were summarized. The experimental methods and research status of finite element analysis were also summarized. Finally, the research trends of AID mechanical performance evaluation were forecasted. The simulator, load, dynamic cycle, motion mode, specimen and test standard would be important research fields in the future.
NASA Technical Reports Server (NTRS)
1978-01-01
Analytical and quantitative economic techniques are applied to the evaluation of the economic benefits of a wide range of substances for space bioprocessing. On the basis of expected clinical applications, as well as the size of the patient that could be affected by the clinical applications, eight substances are recommended for further benefit evaluation. Results show that a transitional probability methodology can be used to model at least one clinical application for each of these substances. In each recommended case, the disease and its therapy are sufficiently well understood and documented, and the statistical data is available to operate the model and produce estimates of the impact of new therapy systems on the cost of treatment, morbidity, and mortality. Utilizing the morbidity and mortality information produced by the model, a standard economic technique called the Value of Human Capital is used to estimate the social welfare benefits that could be attributable to the new therapy systems.
Use of macroinvertebrates to identify cultivated wetlands in the Prairie Pothole Region
Euliss, Ned H.; Mushet, David M.; Johnson, Douglas H.
2001-01-01
We evaluated the use of macroinvertebrates as a potential tool to identify dry and intensively farmed temporary and seasonal wetlands in the Prairie Pothole Region. The techniques we designed and evaluated used the dried remains of invertebrates or their egg banks in soils as indicators of wetlands. For both the dried remains of invertebrates and their egg banks, we weighted each taxon according to its affinity for wetlands or uplands. Our study clearly demonstrated that shells, exoskeletons, head capsules, eggs, and other remains of macroinvertebrates can be used to identify wetlands, even when they are dry, intensively farmed, and difficult to identify as wetlands using standard criteria (i.e., hydrology, hydrophytic vegetation, and hydric soils). Although both dried remains and egg banks identified wetlands, the combination was more useful, especially for identifying drained or filled wetlands. We also evaluated the use of coarse taxonomic groupings to stimulate use of the technique by nonspecialists and obtained satisfactory results in most situations.
Hassoun, Abdo; Karoui, Romdhane
2017-06-13
Although being one of the most vulnerable and perishable products, fish and other seafoods provide a wide range of health-promoting compounds. Recently, the growing interest of consumers in food quality and safety issues has contributed to the increasing demand for sensitive and rapid analytical technologies. Several traditional physicochemical, textural, sensory, and electrical methods have been used to evaluate freshness and authentication of fish and other seafood products. Despite the importance of these standard methods, they are expensive and time-consuming, and often susceptible to large sources of variation. Recently, spectroscopic methods and other emerging techniques have shown great potential due to speed of analysis, minimal sample preparation, high repeatability, low cost, and, most of all, the fact that these techniques are noninvasive and nondestructive and, therefore, could be applied to any online monitoring system. This review describes firstly and briefly the basic principles of multivariate data analysis, followed by the most commonly traditional methods used for the determination of the freshness and authenticity of fish and other seafood products. A special focus is put on the use of rapid and nondestructive techniques (spectroscopic techniques and instrumental sensors) to address several issues related to the quality of these products. Moreover, the advantages and limitations of each technique are reviewed and some perspectives are also given.
Khan, Wajahat Ali; Khattak, Asad Masood; Hussain, Maqbool; Amin, Muhammad Bilal; Afzal, Muhammad; Nugent, Christopher; Lee, Sungyoung
2014-08-01
Heterogeneity in the management of the complex medical data, obstructs the attainment of data level interoperability among Health Information Systems (HIS). This diversity is dependent on the compliance of HISs with different healthcare standards. Its solution demands a mediation system for the accurate interpretation of data in different heterogeneous formats for achieving data interoperability. We propose an adaptive AdapteR Interoperability ENgine mediation system called ARIEN, that arbitrates between HISs compliant to different healthcare standards for accurate and seamless information exchange to achieve data interoperability. ARIEN stores the semantic mapping information between different standards in the Mediation Bridge Ontology (MBO) using ontology matching techniques. These mappings are provided by our System for Parallel Heterogeneity (SPHeRe) matching system and Personalized-Detailed Clinical Model (P-DCM) approach to guarantee accuracy of mappings. The realization of the effectiveness of the mappings stored in the MBO is evaluation of the accuracy in transformation process among different standard formats. We evaluated our proposed system with the transformation process of medical records between Clinical Document Architecture (CDA) and Virtual Medical Record (vMR) standards. The transformation process achieved over 90 % of accuracy level in conversion process between CDA and vMR standards using pattern oriented approach from the MBO. The proposed mediation system improves the overall communication process between HISs. It provides an accurate and seamless medical information exchange to ensure data interoperability and timely healthcare services to patients.
Wang, Mei; Zhao, Jianping; Avula, Bharathi; Wang, Yan-Hong; Chittiboyina, Amar G; Parcher, Jon F; Khan, Ikhlas A
2015-03-18
GC/MS, chiral GC/MS, and chemometric techniques were used to evaluate a large set (n=104) of tea tree oils (TTO) and commercial products purported to contain TTO. Twenty terpenoids were determined in each sample and compared with the standards specified by ISO-4730-2004. Several of the oil samples that were ISO compliant when distilled did not meet the ISO standards in this study primarily due to the presence of excessive p-cymene and/or depletion of terpinenes. Forty-nine percent of the commercial products did not meet the ISO specifications. Four terpenes, viz., α-pinene, limonene, terpinen-4-ol, and α-terpineol, present in TTOs with the (+)-isomer predominant were measured by chiral GC/MS. The results clearly indicated that 28 commercial products contained excessive (+)-isomer or contained the (+)-isomer in concentrations below the norm. Of the 28 outliers, 7 met the ISO standards. There was a substantial subset of commercial products that met ISO standards but displayed unusual enantiomeric+/-ratios. A class predictive model based on the oils that met ISO standards was constructed. The outliers identified by the class predictive model coincided with the samples that displayed an abnormal chiral ratio. Thus, chiral and chemometric analyses could be used to confirm the identification of abnormal commercial products including those that met all of the ISO standards.
48 CFR 9904.401-50 - Techniques for application.
Code of Federal Regulations, 2010 CFR
2010-10-01
.... 9904.401-50 Section 9904.401-50 Federal Acquisition Regulations System COST ACCOUNTING STANDARDS BOARD, OFFICE OF FEDERAL PROCUREMENT POLICY, OFFICE OF MANAGEMENT AND BUDGET PROCUREMENT PRACTICES AND COST ACCOUNTING STANDARDS COST ACCOUNTING STANDARDS 9904.401-50 Techniques for application. (a) The standard...
Guelzow, A; Stamm, O; Martus, P; Kielbassa, A M
2005-10-01
To compare ex vivo various parameters of root canal preparation using a manual technique and six different rotary nickel-titanium (Ni-Ti) instruments (FlexMaster, System GT, HERO 642, K3, ProTaper, and RaCe). A total of 147 extracted mandibular molars were divided into seven groups (n = 21) with equal mean mesio-buccal root canal curvatures (up to 70 degrees), and embedded in a muffle system. All root canals were prepared to size 30 using a crown-down preparation technique for the rotary nickel-titanium instruments and a standardized preparation (using reamers and Hedströem files) for the manual technique. Length modifications and straightening were determined by standardized radiography and a computer-aided difference measurement for every instrument system. Post-operative cross-sections were evaluated by light-microscopic investigation and photographic documentation. Procedural errors, working time and time for instrumentation were recorded. The data were analysed statistically using the Kruskal-Wallis test and the Mann-Whitney U-test. No significant differences were detected between the rotary Ni-Ti instruments for alteration of working length. All Ni-Ti systems maintained the original curvature well, with minor mean degrees of straightening ranging from 0.45 degrees (System GT) to 1.17 degrees (ProTaper). ProTaper had the lowest numbers of irregular post-operative root canal diameters; the results were comparable between the other systems. Instrument fractures occurred with ProTaper in three root canals, whilst preparation with System GT, HERO 642, K3 and the manual technique resulted in one fracture each. Ni-Ti instruments prepared canals more rapidly than the manual technique. The shortest time for instrumentation was achieved with System GT (11.7 s). Under the conditions of this ex vivo study all Ni-Ti systems maintained the canal curvature, were associated with few instrument fractures and were more rapid than a standardized manual technique. ProTaper instruments created more regular canal diameters.
Molecular detection of pathogens in water--the pros and cons of molecular techniques.
Girones, Rosina; Ferrús, Maria Antonia; Alonso, José Luis; Rodriguez-Manzano, Jesus; Calgua, Byron; Corrêa, Adriana de Abreu; Hundesa, Ayalkibet; Carratala, Anna; Bofill-Mas, Sílvia
2010-08-01
Pollution of water by sewage and run-off from farms produces a serious public health problem in many countries. Viruses, along with bacteria and protozoa in the intestine or in urine are shed and transported through the sewer system. Even in highly industrialized countries, pathogens, including viruses, are prevalent throughout the environment. Molecular methods are used to monitor viral, bacterial, and protozoan pathogens, and to track pathogen- and source-specific markers in the environment. Molecular techniques, specifically polymerase chain reaction-based methods, provide sensitive, rapid, and quantitative analytical tools with which to study such pathogens, including new or emerging strains. These techniques are used to evaluate the microbiological quality of food and water, and to assess the efficiency of virus removal in drinking and wastewater treatment plants. The range of methods available for the application of molecular techniques has increased, and the costs involved have fallen. These developments have allowed the potential standardization and automation of certain techniques. In some cases they facilitate the identification, genotyping, enumeration, viability assessment, and source-tracking of human and animal contamination. Additionally, recent improvements in detection technologies have allowed the simultaneous detection of multiple targets in a single assay. However, the molecular techniques available today and those under development require further refinement in order to be standardized and applicable to a diversity of matrices. Water disinfection treatments may have an effect on the viability of pathogens and the numbers obtained by molecular techniques may overestimate the quantification of infectious microorganisms. The pros and cons of molecular techniques for the detection and quantification of pathogens in water are discussed. (c) 2010 Elsevier Ltd. All rights reserved.
The importance of intestinal ultrasound and elastographic techniques in inflammatory bowel diseases.
Marin, Andreea; Tribus, Laura; Fierbinteanu-Braticevici, Carmen
2018-05-02
Inflammatory bowel diseases have an important impact upon the economic and social status due to their increasing incidence and prevalence, often affecting young people. At the moment, the therapeutic goal goes beyond the improvement of symptoms and laboratory parameters, being represented by endoscopic mucosal healing, changing the disease's natural history. Even though endoscopy is the gold standard for the assessment of mucosal healing, it is an invasive maneuver and it lacks good repeatability. These patients require frequent evaluation; therefore, interest for noninvasive techniques has risen.As a consequence, the importance of intestinal ultrasound has increased lately and recent studies support its use to assess the degree of inflammation, to differentiate between remission and relapse, to monitor therapy response and guide treatment, to evaluate prognosis, and to diagnose complications. Another promising noninvasive imagistic technique is elastography which has gained interest because of its capacity to discriminate between inflammatory and fibrotic tissue, taking into account the different therapeutic options for the fibrotic strictures compared to inflammatory processes. This review summarizes the actual recommendations regarding the use of intestinal ultrasound and elastographic techniques for the diagnosis and monitoring of inflammatory bowel diseases.
Multimodal 3D cancer-mimicking optical phantom
Smith, Gennifer T.; Lurie, Kristen L.; Zlatev, Dimitar V.; Liao, Joseph C.; Ellerbee Bowden, Audrey K.
2016-01-01
Three-dimensional (3D) organ-mimicking phantoms provide realistic imaging environments for testing various aspects of optical systems, including for evaluating new probe designs, characterizing the diagnostic potential of new technologies, and assessing novel image processing algorithms prior to validation in real tissue. We introduce and characterize the use of a new material, Dragon Skin (Smooth-On Inc.), and fabrication technique, air-brushing, for fabrication of a 3D phantom that mimics the appearance of a real organ under multiple imaging modalities. We demonstrate the utility of the material and technique by fabricating the first 3D, hollow bladder phantom with realistic normal and multi-stage pathology features suitable for endoscopic detection using the gold standard imaging technique, white light cystoscopy (WLC), as well as the complementary imaging modalities of optical coherence tomography and blue light cystoscopy, which are aimed at improving the sensitivity and specificity of WLC to bladder cancer detection. The flexibility of the material and technique used for phantom construction allowed for the representation of a wide range of diseased tissue states, ranging from inflammation (benign) to high-grade cancerous lesions. Such phantoms can serve as important tools for trainee education and evaluation of new endoscopic instrumentation. PMID:26977369
DIFFUSION-WEIGHTED IMAGING OF THE LIVER: TECHNIQUES AND APPLICATIONS
Lewis, Sara; Dyvorne, Hadrien; Cui, Yong; Taouli, Bachir
2014-01-01
SYNOPSIS Diffusion weighted MRI (DWI) is a technique that assesses the cellularity, tortuosity of the extracellular/extravascular space and cell membrane density based upon differences in water proton mobility in tissues. The strength of the diffusion weighting is reflected by the b-value. DWI using several b-values enables quantification of the apparent diffusion coefficient (ADC). DWI is increasingly employed in liver imaging for multiple reasons: it can add useful qualitative and quantitative information to conventional imaging sequences, it is acquired relatively quickly, it is easily incorporated into existing clinical protocols, and it is a non-contrast technique. DWI is useful for focal liver lesion detection and characterization, for the assessment of post-treatment tumor response and for evaluation of diffuse liver disease. ADC quantification can be used to characterize lesions as cystic/necrotic or solid and for predicting tumor response to therapy. Advanced diffusion methods such as IVIM (intravoxel incoherent motion) may have potential for detection, staging and evaluation of the progression of liver fibrosis and for liver lesion characterization. The lack of standardization of DWI technique including choice of b-values and sequence parameters has somewhat limited its widespread adoption. PMID:25086935
Multiple regression technique for Pth degree polynominals with and without linear cross products
NASA Technical Reports Server (NTRS)
Davis, J. W.
1973-01-01
A multiple regression technique was developed by which the nonlinear behavior of specified independent variables can be related to a given dependent variable. The polynomial expression can be of Pth degree and can incorporate N independent variables. Two cases are treated such that mathematical models can be studied both with and without linear cross products. The resulting surface fits can be used to summarize trends for a given phenomenon and provide a mathematical relationship for subsequent analysis. To implement this technique, separate computer programs were developed for the case without linear cross products and for the case incorporating such cross products which evaluate the various constants in the model regression equation. In addition, the significance of the estimated regression equation is considered and the standard deviation, the F statistic, the maximum absolute percent error, and the average of the absolute values of the percent of error evaluated. The computer programs and their manner of utilization are described. Sample problems are included to illustrate the use and capability of the technique which show the output formats and typical plots comparing computer results to each set of input data.
Vasanawala, Shreyas S; Yu, Huanzhou; Shimakawa, Ann; Jeng, Michael; Brittain, Jean H
2012-01-01
MRI imaging of hepatic iron overload can be achieved by estimating T(2) values using multiple-echo sequences. The purpose of this work is to develop and clinically evaluate a weighted least squares algorithm based on T(2) Iterative Decomposition of water and fat with Echo Asymmetry and Least-squares estimation (IDEAL) technique for volumetric estimation of hepatic T(2) in the setting of iron overload. The weighted least squares T(2) IDEAL technique improves T(2) estimation by automatically decreasing the impact of later, noise-dominated echoes. The technique was evaluated in 37 patients with iron overload. Each patient underwent (i) a standard 2D multiple-echo gradient echo sequence for T(2) assessment with nonlinear exponential fitting, and (ii) a 3D T(2) IDEAL technique, with and without a weighted least squares fit. Regression and Bland-Altman analysis demonstrated strong correlation between conventional 2D and T(2) IDEAL estimation. In cases of severe iron overload, T(2) IDEAL without weighted least squares reconstruction resulted in a relative overestimation of T(2) compared with weighted least squares. Copyright © 2011 Wiley-Liss, Inc.
Zardi, Enrico Maria; Di Matteo, Francesco Maria; Pacella, Claudio Maurizio; Sanyal, Arun J
2016-01-01
Portal hypertension is a severe syndrome that may derive from pre-sinusoidal, sinusoidal and post-sinusoidal causes. As a consequence, several complications (i.e., ascites, oesophageal varices) may develop. In sinusoidal portal hypertension, hepatic venous pressure gradient (HVPG) is a reliable method for defining the grade of portal pressure, establishing the effectiveness of the treatment and predicting the occurrence of complications; however, some questions exist regarding its ability to discriminate bleeding from nonbleeding varices in cirrhotic patients. Other imaging techniques (transient elastography, endoscopy, endosonography and duplex Doppler sonography) for assessing causes and complications of portal hypertensive syndrome are available and may be valuable for the management of these patients. In this review, we evaluate invasive and non-invasive techniques currently employed to obtain a clinical prediction of deadly complications, such as variceal bleeding in patients affected by sinusoidal portal hypertension, in order to create a diagnostic algorithm to manage them. Again, HVPG appears to be the reference standard to evaluate portal hypertension and monitor the response to treatment, but its ability to predict several complications and support management decisions might be further improved through the diagnostic combination with other imaging techniques. PMID:24328372
Zardi, Enrico Maria; Di Matteo, Francesco Maria; Pacella, Claudio Maurizio; Sanyal, Arun J
2014-02-01
Portal hypertension is a severe syndrome that may derive from pre-sinusoidal, sinusoidal, and post-sinusoidal causes. As a consequence, several complications (i.e. ascites, oesophageal varices) may develop. In sinusoidal portal hypertension, hepatic venous pressure gradient (HVPG) is a reliable method for defining the grade of portal pressure, establishing the effectiveness of the treatment, and predicting the occurrence of complications; however, some questions exist regarding its ability to discriminate bleeding from non-bleeding varices in cirrhotic patients. Other imaging techniques (transient elastography, endoscopy, endosonography, and duplex Doppler sonography) for assessing causes and complications of portal hypertensive syndrome are available and may be valuable for the management of these patients. In this review, we evaluate invasive and non-invasive techniques currently employed to obtain a clinical prediction of deadly complications, such as variceal bleeding in patients affected by sinusoidal portal hypertension, in order to create a diagnostic algorithm to manage them. Again, HVPG appears to be the reference standard to evaluate portal hypertension and monitor the response to treatment, but its ability to predict several complications and support management decisions might be further improved through the diagnostic combination with other imaging techniques.
NASA Astrophysics Data System (ADS)
Ilev, Ilko K.; Walker, Bennett; Calhoun, William; Hassan, Moinuddin
2016-03-01
Biophotonics is an emerging field in modern biomedical technology that has opened up new horizons for transfer of state-of-the-art techniques from the areas of lasers, fiber optics and biomedical optics to the life sciences and medicine. This field continues to vastly expand with advanced developments across the entire spectrum of biomedical applications ranging from fundamental "bench" laboratory studies to clinical patient "bedside" diagnostics and therapeutics. However, in order to translate these technologies to clinical device applications, the scientific and industrial community, and FDA are facing the requirement for a thorough evaluation and review of laser radiation safety and efficacy concerns. In many cases, however, the review process is complicated due the lack of effective means and standard test methods to precisely analyze safety and effectiveness of some of the newly developed biophotonics techniques and devices. There is, therefore, an immediate public health need for new test protocols, guidance documents and standard test methods to precisely evaluate fundamental characteristics, performance quality and safety of these technologies and devices. Here, we will overview our recent developments of novel test methodologies for safety and efficacy evaluation of some emerging biophotonics technologies and medical devices. These methodologies are based on integrating the advanced features of state-of-the-art optical sensor technologies and approaches such as high-resolution fiber-optic sensing, confocal and optical coherence tomography imaging, and infrared spectroscopy. The presentation will also illustrate some methodologies developed and implemented for testing intraocular lens implants, biochemical contaminations of medical devices, ultrahigh-resolution nanoscopy, and femtosecond laser therapeutics.
Sawani, Shefali; Arora, Vipin; Jaiswal, Shikha; Nikhil, Vineeta
2014-01-01
Background: Evaluation of microleakage is important for assessing the success of new restorative materials and methods. Aim and Objectives: Comparative evaluation of microleakage in Class II restorations using open vs. closed centripetal build-up techniques with different lining materials. Materials and Methods: Standardized mesi-occlusal (MO) and distoocclusal (DO) Class II tooth preparations were preparedon 53 molars and samples were randomly divided into six experimental groups and one control group for restorations. Group 1: Open-Sandwich technique (OST) with flowable composite at the gingival seat. Group 2: OST with resin-modified glass ionomer cement (RMGIC) at the gingival seat. Group 3: Closed-Sandwich technique (CST) with flowable composite at the pulpal floor and axial wall. Group 4: CST with RMGIC at the pulpal floor and axial wall. Group 5: OST with flowable composite at the pulpal floor, axial wall, and gingival seat. Group 6: OST with RMGIC at the pulpal floor, axial wall, and gingival seat. Group 7: Control — no lining material, centripetal technique only. After restorations and thermocycling, apices were sealed and samples were immersed in 0.5% basic fuchsin dye. Sectioning was followed by stereomicroscopic evaluation. Results: Results were analyzed using Post Hoc Bonferroni test (statistics is not a form of tabulation). Cervical scores of control were more than the exprimental groups (P < 0.05). Less microleakage was observed in CST than OST in all experimental groups (P < 0.05). However, insignificant differences were observed among occlusal scores of different groups (P > 0.05). Conclusion: Class II composite restorations with centripetal build-up alone or when placed with CST reduces the cervical microleakage when compared to OST. PMID:25125847
Chapiro, Julius; Wood, Laura D.; Lin, MingDe; Duran, Rafael; Cornish, Toby; Lesage, David; Charu, Vivek; Schernthaner, Rüdiger; Wang, Zhijun; Tacher, Vania; Savic, Lynn Jeanette; Kamel, Ihab R.
2014-01-01
Purpose To evaluate the diagnostic performance of three-dimensional (3Dthree-dimensional) quantitative enhancement-based and diffusion-weighted volumetric magnetic resonance (MR) imaging assessment of hepatocellular carcinoma (HCChepatocellular carcinoma) lesions in determining the extent of pathologic tumor necrosis after transarterial chemoembolization (TACEtransarterial chemoembolization). Materials and Methods This institutional review board–approved retrospective study included 17 patients with HCChepatocellular carcinoma who underwent TACEtransarterial chemoembolization before surgery. Semiautomatic 3Dthree-dimensional volumetric segmentation of target lesions was performed at the last MR examination before orthotopic liver transplantation or surgical resection. The amount of necrotic tumor tissue on contrast material–enhanced arterial phase MR images and the amount of diffusion-restricted tumor tissue on apparent diffusion coefficient (ADCapparent diffusion coefficient) maps were expressed as a percentage of the total tumor volume. Visual assessment of the extent of tumor necrosis and tumor response according to European Association for the Study of the Liver (EASLEuropean Association for the Study of the Liver) criteria was performed. Pathologic tumor necrosis was quantified by using slide-by-slide segmentation. Correlation analysis was performed to evaluate the predictive values of the radiologic techniques. Results At histopathologic examination, the mean percentage of tumor necrosis was 70% (range, 10%–100%). Both 3Dthree-dimensional quantitative techniques demonstrated a strong correlation with tumor necrosis at pathologic examination (R2 = 0.9657 and R2 = 0.9662 for quantitative EASLEuropean Association for the Study of the Liver and quantitative ADCapparent diffusion coefficient, respectively) and a strong intermethod agreement (R2 = 0.9585). Both methods showed a significantly lower discrepancy with pathologically measured necrosis (residual standard error [RSEresidual standard error] = 6.38 and 6.33 for quantitative EASLEuropean Association for the Study of the Liver and quantitative ADCapparent diffusion coefficient, respectively), when compared with non-3Dthree-dimensional techniques (RSEresidual standard error = 12.18 for visual assessment). Conclusion This radiologic-pathologic correlation study demonstrates the diagnostic accuracy of 3Dthree-dimensional quantitative MR imaging techniques in identifying pathologically measured tumor necrosis in HCChepatocellular carcinoma lesions treated with TACEtransarterial chemoembolization. © RSNA, 2014 Online supplemental material is available for this article. PMID:25028783
Christmann, Corinna Anna; Hoffmann, Alexandra; Bleser, Gabriele
2017-02-23
Chronic stress has been shown to be associated with disease. This link is not only direct but also indirect through harmful health behavior such as smoking or changing eating habits. The recent mHealth trend offers a new and promising approach to support the adoption and maintenance of appropriate stress management techniques. However, only few studies have dealt with the inclusion of evidence-based content within stress management apps for mobile phones. The aim of this study was to evaluate stress management apps on the basis of a new taxonomy of effective emotion-focused stress management techniques and an established taxonomy of behavior change techniques. Two trained and independent raters evaluated 62 free apps found in Google Play with regard to 26 behavior change and 15 emotion-focused stress management techniques in October 2015. The apps included an average of 4.3 behavior change techniques (SD 4.2) and 2.8 emotion-focused stress management techniques (SD 2.6). The behavior change technique score and stress management technique score were highly correlated (r=.82, P=.01). The broad variation of different stress management strategies found in this sample of apps goes in line with those found in conventional stress management interventions and self-help literature. Moreover, this study provided a first step toward more detailed and standardized taxonomies, which can be used to investigate evidence-based content in stress management interventions and enable greater comparability between different intervention types. ©Corinna Anna Christmann, Alexandra Hoffmann, Gabriele Bleser. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 23.02.2017.
48 CFR 9904.413-50 - Techniques for application.
Code of Federal Regulations, 2010 CFR
2010-10-01
.... 9904.413-50 Section 9904.413-50 Federal Acquisition Regulations System COST ACCOUNTING STANDARDS BOARD... ACCOUNTING STANDARDS COST ACCOUNTING STANDARDS 9904.413-50 Techniques for application. (a) Assignment of actuarial gains and losses. (1) In accordance with the provisions of Cost Accounting Standard 9904.412...
Diagnostic procedures in tularaemia with special focus on molecular and immunological techniques.
Splettstoesser, W D; Tomaso, H; Al Dahouk, S; Neubauer, H; Schuff-Werner, P
2005-08-01
Tularaemia is a severe bacterial zoonosis caused by the highly infectious agent Francisella tularensis. It is endemic in countries of the northern hemisphere ranging from North America to Europe, Asia and Japan. Very recently, Francisella-like strains causing disease in humans were described from tropical northern Australia. In the last decade, efforts have been made to develop sensitive and specific immunological and molecular techniques for the laboratory diagnosis of tularaemia and also for the definite identification of members of the species F. tularensis and its four subspecies. Screening for the keyword 'Francisella' a Medline search over the last decade was performed and articles describing diagnostic methods for tularaemia and its causative agent were selected. Besides classical microbiological techniques (cultivation, biochemical profiling, susceptibility testing) several new immunological and molecular approaches to identify F. tularensis have been introduced employing highly specific antibodies and various polymerase chain reaction (PCR)-based methods. Whereas direct antigen detection by enzyme-linked immunosorbent assay (ELISA) or immunofluorescence might allow early presumptive diagnosis of tularaemia, these methods--like all PCR techniques--still await further evaluation. Therefore, diagnosis of tularaemia still relies mainly on the demonstration of specific antibodies in the host. ELISA and immunoblot methods started to replace the standard tube or micro-agglutination assays. However, the diagnostic value of antibody detection in the very early clinical phase of tularaemia is limited. Francisella tularensis is regarded as a 'highest priority' biological agent (category 'A' according to the CDC, Atlanta, GA, USA), thus rapid and reliable diagnosis of tularaemia is required not only for a timely onset of therapy, the handling of outbreak investigations but also for the surveillance of endemic foci. Only very recently, evaluated test kits for serological diagnosis of human tularaemia became available, while the introduction of standardized molecular techniques for detection and typing is still missing.
Etalon (standard) for surface potential distribution produced by electric activity of the heart.
Szathmáry, V; Ruttkay-Nedecký, I
1981-01-01
The authors submit etalon (standard) equipotential maps as an aid in the evaluation of maps of surface potential distributions in living subjects. They were obtained by measuring potentials on the surface of an electrolytic tank shaped like the thorax. The individual etalon maps were determined in such a way that the parameters of the physical dipole forming the source of the electric field in the tank corresponded to the mean vectorcardiographic parameters measured in a healthy population sample. The technique also allows a quantitative estimate of the degree of non-dipolarity of the heart as the source of the electric field.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
1969-07-01
The Fifth International Conference on Nondestructive Testing was held in Montreal, Canada, for the purpose of promoting international collaboration in all matters related to the development and use of nondestructive test methods. A total of 82 papers were selected for presentation. Session titles included: evaluation of material quality; ultrasonics - identification and measurements; thermal methods; testing of welds; visual aids in nondestructive testing; measurements of stress and elastic properties; magnetic and eddy-current methods; surface methods and neutron radiography; standardization - general; ultrasonics at elevated temperatures; applications; x-ray techniques; radiography; ultrasonic standardization; training and qualification; and, correlation of weld defects.
Efficient calculation of the polarizability: a simplified effective-energy technique
NASA Astrophysics Data System (ADS)
Berger, J. A.; Reining, L.; Sottile, F.
2012-09-01
In a recent publication [J.A. Berger, L. Reining, F. Sottile, Phys. Rev. B 82, 041103(R) (2010)] we introduced the effective-energy technique to calculate in an accurate and numerically efficient manner the GW self-energy as well as the polarizability, which is required to evaluate the screened Coulomb interaction W. In this work we show that the effective-energy technique can be used to further simplify the expression for the polarizability without a significant loss of accuracy. In contrast to standard sum-over-state methods where huge summations over empty states are required, our approach only requires summations over occupied states. The three simplest approximations we obtain for the polarizability are explicit functionals of an independent- or quasi-particle one-body reduced density matrix. We provide evidence of the numerical accuracy of this simplified effective-energy technique as well as an analysis of our method.
Non-invasive spectroscopic techniques in the diagnosis of non-melanoma skin cancer
NASA Astrophysics Data System (ADS)
Drakaki, E.; Sianoudis, IA; Zois, EN; Makropoulou, M.; Serafetinides, AA; Dessinioti, C.; Stefanaki, E.; Stratigos, AJ; Antoniou, C.; Katsambas, A.; Christofidou, E.
2017-11-01
The number of non-melanoma skin cancers is increasing worldwide and has become an important health and economic issue. Early detection and treatment of skin cancer can significantly improve patient outcome. Therefore there is an increase in the demand for proper management and effective non-invasive diagnostic modalities in order to avoid relapses or unnecessary treatments. Although the gold standard of diagnosis for non-melanoma skin cancers is biopsy followed by histopathology evaluation, optical non-invasive diagnostic tools have obtained increased attention. Emerging non-invasive or minimal invasive techniques with possible application in the diagnosis of non-melanoma skin cancers include high-definition optical coherence tomography, fluorescence spectroscopy, oblique incidence diffuse reflectance spectrometry among others spectroscopic techniques. Our findings establish how those spectrometric techniques can be used to more rapidly and easily diagnose skin cancer in an accurate and automated manner in the clinic.
In vitro evaluation of marginal adaptation in five ceramic restoration fabricating techniques.
Ural, Cağri; Burgaz, Yavuz; Saraç, Duygu
2010-01-01
To compare in vitro the marginal adaptation of crowns manufactured using ceramic restoration fabricating techniques. Fifty standardized master steel dies simulating molars were produced and divided into five groups, each containing 10 specimens. Test specimens were fabricated with CAD/CAM, heat-press, glass-infiltration, and conventional lost-wax techniques according to manufacturer instructions. Marginal adaptation of the test specimens was measured vertically before and after cementation using SEM. Data were statistically analyzed by one-way ANOVA with Tukey HSD tests (a = .05). Marginal adaptation of ceramic crowns was affected by fabrication technique and cementation process (P < .001). The lowest marginal opening values were obtained with Cerec-3 crowns before and after cementation (P < .001). The highest marginal discrepancy values were obtained with PFM crowns before and after cementation. Marginal adaptation values obtained in the compared systems were within clinically acceptable limits. Cementation causes a significant increase in the vertical marginal discrepancies of the test specimens.
Zoppetti, Nicola; Bogi, Andrea; Pinto, Iole; Andreuccetti, Daniele
2015-02-01
In this paper, a procedure is described for the assessment of human exposure to magnetic fields with complex waveforms generated by arc-welding equipment. The work moves from the analysis of relevant guidelines and technical standards, underlining their strengths and their limits. Then, the procedure is described with particular attention to the techniques used to treat complex waveform fields. Finally, the procedure is applied to concrete cases encountered in the workplace. The discussion of the results highlights the critical points in the procedure, as well as those related to the evolution of the technical and exposure standards. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Endoscopic and Photodynamic Therapy of Cholangiocarcinoma
Meier, Benjamin; Caca, Karel
2016-01-01
Background Most patients with cholangiocarcinoma (CCA) have unresectable disease. Endoscopic bile duct drainage is one of the major objectives of palliation of obstructive jaundice. Methods/Results Stent implantation using endoscopic retrograde cholangiography is considered to be the standard technique. Unilateral versus bilateral stenting is associated with different advantages and disadvantages; however, a standard approach is still not defined. As there are various kinds of stents, there is an ongoing discussion on which stent to use in which situation. Palliation of obstructive jaundice can be augmented through the use of photodynamic therapy (PDT). Studies have shown a prolonged survival for the combinations of PDT and different stent applications as well as combinations of PDT and additional systemic chemotherapy. Conclusion More well-designed studies are needed to better evaluate and standardize endoscopic treatment of unresectable CCA. PMID:28229075
Endoscopic and Photodynamic Therapy of Cholangiocarcinoma.
Meier, Benjamin; Caca, Karel
2016-12-01
Most patients with cholangiocarcinoma (CCA) have unresectable disease. Endoscopic bile duct drainage is one of the major objectives of palliation of obstructive jaundice. Stent implantation using endoscopic retrograde cholangiography is considered to be the standard technique. Unilateral versus bilateral stenting is associated with different advantages and disadvantages; however, a standard approach is still not defined. As there are various kinds of stents, there is an ongoing discussion on which stent to use in which situation. Palliation of obstructive jaundice can be augmented through the use of photodynamic therapy (PDT). Studies have shown a prolonged survival for the combinations of PDT and different stent applications as well as combinations of PDT and additional systemic chemotherapy. More well-designed studies are needed to better evaluate and standardize endoscopic treatment of unresectable CCA.
Right parasternal imaging: an underutilized echocardiographic technique.
Marcella, C P; Johnson, L E
1993-01-01
If the echocardiographer uses only standard imaging planes, he or she may fail to obtain vital information about the aorta, atrial septum, superior and inferior vena cavae, and the coronary arteries. The evaluation of caval-to-systemic venous atrial connections (Senning or Mustard) in transposition of the great arteries of systemic vena caval or right atrial-to-pulmonary anastomosis (Fontan) in tricuspid atresia and single ventricle may not be adequately seen when only the standard left parasternal, apical, subcostal, and suprasternal imaging planes are used. Therefore, the use of the right parasternal imaging plane may help to provide crucial information regarding these areas when the standard views are unable to delineate them adequately. The right parasternal window is an additional echocardiographic window that should become part of a complete echocardiographic examination.
Staining-free malaria diagnostics by multispectral and multimodality light-emitting-diode microscopy
NASA Astrophysics Data System (ADS)
Merdasa, Aboma; Brydegaard, Mikkel; Svanberg, Sune; Zoueu, Jeremie T.
2013-03-01
We report an accurate optical differentiation technique between healthy and malaria-infected erythrocytes by quasi-simultaneous measurements of transmittance, reflectance, and scattering properties of unstained blood smears using a multispectral and multimode light-emitting diode microscope. We propose a technique for automated imaging, identification, and counting of malaria-infected erythrocytes for real-time and cost-effective parasitaemia diagnosis as an effective alternative to the manual screening of stained blood smears, now considered to be the gold standard in malaria diagnosis. We evaluate the performance of our algorithm against manual estimations of an expert and show a spectrally resolved increased scattering from malaria-infected blood cells.
NASA Astrophysics Data System (ADS)
Takács, S.; Vasváry, L.; Tárkányi, F.
1994-05-01
Excitation functions of proton induced reactions on natFe(p, xn) 56Co have been remeasured in the energy region up to 18 MeV using stacked foil technique and standard high resolution gamma-ray spectrometry at the Debrecen MGC-20E cyclotron. Compilation of the available data measured between 1959 and 1993 has been made. The corresponding excitation functions have been reviewed, critical comparison of all the available data was done to obtain the most accurate data set. The feasibility of the evaluated data set was checked by reproducing experimental calibration curves for TLA by calculation.
Raman Spectroscopic Measurements of Co2 Dissolved in Seawater for Laser Remote Sensing in Water
NASA Astrophysics Data System (ADS)
Somekawa, Toshihiro; Fujita, Masayuki
2016-06-01
We examined the applicability of Raman lidar technique as a laser remote sensing tool in water. The Raman technique has already been used successfully for measurements of CO2 gas dissolved in water and bubbles. Here, the effect of seawater on CO2 Raman spectra has been evaluated. A frequency doubled Q-switched Nd:YAG laser (532 nm) was irradiated to CO2 gas dissolved in a standard seawater. In seawater, the Raman signals at 984 and 1060-1180 cm-1 from SO42- were detected, which shows no spectral interference caused by Raman signals derived from CO2.
New echocardiographic techniques for evaluation of left atrial mechanics.
Todaro, Maria Chiara; Choudhuri, Indrajit; Belohlavek, Marek; Jahangir, Arshad; Carerj, Scipione; Oreto, Lilia; Khandheria, Bijoy K
2012-12-01
Until recently the left atrium had been subordinate to the left ventricle, but cardiologists now recognize that left atrial (LA) function is indispensable to normal circulatory performance. Transthoracic two-dimensional (2D) and Doppler echocardiography can elucidate parameters of LA function non-invasively. Yet, with the advent of 2D speckle-tracking echocardiography, we are able to detect early LA dysfunction even before structural changes occur. This is pivotal in some common disease states, such as atrial fibrillation, hypertension, and heart failure, in which LA deformation parameters can influence clinical management. However, a unique standardized technique to investigate LA deformation needs to be validated.
Recovery of hygiene water by multifiltration. [in space shuttle orbiters
NASA Technical Reports Server (NTRS)
Putnam, David F.; Jolly, Clifford D.; Colombo, Gerald V.; Price, Don
1989-01-01
A multifiltration hygiene water reclamation process that utilizes adsorption and particulate filtration techniques is described and evaluated. The applicability of the process is tested using a simulation of a 4-man subsystem operation for 240 days. It is proposed the process has a 10 year life, weighs 236 kg, and uses 88 kg of expendable filters and adsorption beds to process 8424 kg of water. The data reveal that the multifiltration is an efficient nonphase change technique for hygiene water recovery and that the chemical and microbiological purity of the product water is within the standards specified for the Space Station hygiene water.
Haverkort, J J Mark; Leenen, Luke P H
2017-10-01
Presently used evaluation techniques rely on 3 traditional dimensions: reports from observers, registration system data, and observational cameras. Some of these techniques are observer-dependent and are not reproducible for a second review. This proof-of-concept study aimed to test the feasibility of extending evaluation to a fourth dimension, the patient's perspective. Footage was obtained during a large, full-scale hospital trauma drill. Two mock victims were equipped with point-of-view cameras filming from the patient's head. Based on the Major Incident Hospital's first experience during the drill, a protocol was developed for a prospective, standardized method to evaluate a hospital's major incident response from the patient's perspective. The protocol was then tested in a second drill for its feasibility. New insights were gained after review of the footage. The traditional observer missed some of the evaluation points, which were seen on the point-of-view cameras. The information gained from the patient's perspective proved to be implementable into the designed protocol. Use of point-of-view camera recordings from a mock patient's perspective is a valuable addition to traditional evaluation of trauma drills and trauma care. Protocols should be designed to optimize and objectify judgement of such footage. (Disaster Med Public Health Preparedness. 2017;11:594-599).
Romli, Muhammad Hibatullah; Mackenzie, Lynette; Lovarini, Meryl; Tan, Maw Pin; Clemson, Lindy
2018-03-01
Home hazards are associated with falls among older people living in the community. However, evaluating home hazards is a complex process as environmental factors vary according to geography, culture, and architectural design. As a result, many health practitioners commonly use nonstandardized assessment methods that may lead to inaccurate findings. Thus, the aim of this systematic review was to identify standardized instruments for evaluating home hazards related to falls and evaluate the clinimetric properties of these instruments for use by health practitioners. A systematic search was conducted in the Medline, CINAHL, AgeLine, Web of Science databases, and the University of Sydney Library CrossSearch Engine. Study screening, assessment, and quality ratings were conducted independently. Thirty-six studies were identified describing 19 instruments and three assessment techniques. The clinimetric properties varied between instruments. The Home Falls and Accidents Screening Tool, Home Safety Self-Assessment Tool, In-Home Occupational Performance Evaluation, and Westmead Home Safety Assessment were the instruments with high potential for evaluating home hazards associated with falls. Health practitioners can choose the most appropriate instruments for their practice, as a range of standardized instruments with established clinimetric properties are available.
Quigley, Elizabeth A; Tokay, Barbara A; Jewell, Sarah T; Marchetti, Michael A; Halpern, Allan C
2015-08-01
Photographs are invaluable dermatologic diagnostic, management, research, teaching, and documentation tools. Digital Imaging and Communications in Medicine (DICOM) standards exist for many types of digital medical images, but there are no DICOM standards for camera-acquired dermatologic images to date. To identify and describe existing or proposed technology and technique standards for camera-acquired dermatologic images in the scientific literature. Systematic searches of the PubMed, EMBASE, and Cochrane databases were performed in January 2013 using photography and digital imaging, standardization, and medical specialty and medical illustration search terms and augmented by a gray literature search of 14 websites using Google. Two reviewers independently screened titles of 7371 unique publications, followed by 3 sequential full-text reviews, leading to the selection of 49 publications with the most recent (1985-2013) or detailed description of technology or technique standards related to the acquisition or use of images of skin disease (or related conditions). No universally accepted existing technology or technique standards for camera-based digital images in dermatology were identified. Recommendations are summarized for technology imaging standards, including spatial resolution, color resolution, reproduction (magnification) ratios, postacquisition image processing, color calibration, compression, output, archiving and storage, and security during storage and transmission. Recommendations are also summarized for technique imaging standards, including environmental conditions (lighting, background, and camera position), patient pose and standard view sets, and patient consent, privacy, and confidentiality. Proposed standards for specific-use cases in total body photography, teledermatology, and dermoscopy are described. The literature is replete with descriptions of obtaining photographs of skin disease, but universal imaging standards have not been developed, validated, and adopted to date. Dermatologic imaging is evolving without defined standards for camera-acquired images, leading to variable image quality and limited exchangeability. The development and adoption of universal technology and technique standards may first emerge in scenarios when image use is most associated with a defined clinical benefit.
Culture in the Cockpit-CRM in a Multicultural World
NASA Technical Reports Server (NTRS)
Engle, Michael
2000-01-01
Crew Resource Management (CRM) is fundamentally a method for enhancing personal interactions among crewmembers so that safety and efficiency are increased, and at its core involves issues of culture and social interaction. Since CRM is increasingly being adopted by foreign carriers, it is important to evaluate standard CRM techniques from a cultural standpoint, especially if some of these techniques may be enhanced by adapting them to particular cultures. The purpose of this paper is to propose a model for an ideal CRM culture, and to suggest ways that CRM may be adapted to suit particular cultures. The research method was a simple literature search to gather data on CRM techniques and multicultural crews. The results indicate that CRM can be tailored to specific cultures for maximum effectiveness.
Lin, Jolinta; Kligerman, Seth; Goel, Rakhi; Sajedi, Payam; Suntharalingam, Mohan
2015-01-01
Molecular imaging techniques are increasingly being used in addition to standard imaging methods such as endoscopic ultrasound (EUS) and computed tomography (CT) for many cancers including those of the esophagus. In this review, we will discuss the utility of the most widely used molecular imaging technique, 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET). 18F-FDG PET has a variety of potential applications ranging from improving staging accuracy at the time of initial diagnosis to assisting in radiation target volume delineation. Furthermore, 18F-FDG PET can be used to evaluate treatment response after completion of neoadjuvant therapy or potentially during neoadjuvant therapy. Finally, we will also discuss other novel molecular imaging techniques that have potential to further improve cancer care. PMID:25642333
Multi-scale pixel-based image fusion using multivariate empirical mode decomposition.
Rehman, Naveed ur; Ehsan, Shoaib; Abdullah, Syed Muhammad Umer; Akhtar, Muhammad Jehanzaib; Mandic, Danilo P; McDonald-Maier, Klaus D
2015-05-08
A novel scheme to perform the fusion of multiple images using the multivariate empirical mode decomposition (MEMD) algorithm is proposed. Standard multi-scale fusion techniques make a priori assumptions regarding input data, whereas standard univariate empirical mode decomposition (EMD)-based fusion techniques suffer from inherent mode mixing and mode misalignment issues, characterized respectively by either a single intrinsic mode function (IMF) containing multiple scales or the same indexed IMFs corresponding to multiple input images carrying different frequency information. We show that MEMD overcomes these problems by being fully data adaptive and by aligning common frequency scales from multiple channels, thus enabling their comparison at a pixel level and subsequent fusion at multiple data scales. We then demonstrate the potential of the proposed scheme on a large dataset of real-world multi-exposure and multi-focus images and compare the results against those obtained from standard fusion algorithms, including the principal component analysis (PCA), discrete wavelet transform (DWT) and non-subsampled contourlet transform (NCT). A variety of image fusion quality measures are employed for the objective evaluation of the proposed method. We also report the results of a hypothesis testing approach on our large image dataset to identify statistically-significant performance differences.
Multi-Scale Pixel-Based Image Fusion Using Multivariate Empirical Mode Decomposition
Rehman, Naveed ur; Ehsan, Shoaib; Abdullah, Syed Muhammad Umer; Akhtar, Muhammad Jehanzaib; Mandic, Danilo P.; McDonald-Maier, Klaus D.
2015-01-01
A novel scheme to perform the fusion of multiple images using the multivariate empirical mode decomposition (MEMD) algorithm is proposed. Standard multi-scale fusion techniques make a priori assumptions regarding input data, whereas standard univariate empirical mode decomposition (EMD)-based fusion techniques suffer from inherent mode mixing and mode misalignment issues, characterized respectively by either a single intrinsic mode function (IMF) containing multiple scales or the same indexed IMFs corresponding to multiple input images carrying different frequency information. We show that MEMD overcomes these problems by being fully data adaptive and by aligning common frequency scales from multiple channels, thus enabling their comparison at a pixel level and subsequent fusion at multiple data scales. We then demonstrate the potential of the proposed scheme on a large dataset of real-world multi-exposure and multi-focus images and compare the results against those obtained from standard fusion algorithms, including the principal component analysis (PCA), discrete wavelet transform (DWT) and non-subsampled contourlet transform (NCT). A variety of image fusion quality measures are employed for the objective evaluation of the proposed method. We also report the results of a hypothesis testing approach on our large image dataset to identify statistically-significant performance differences. PMID:26007714
Advantage of four-electrode over two-electrode defibrillators
NASA Astrophysics Data System (ADS)
Bragard, J.; Šimić, A.; Laroze, D.; Elorza, J.
2015-12-01
Defibrillation is the standard clinical treatment used to stop ventricular fibrillation. An electrical device delivers a controlled amount of electrical energy via a pair of electrodes in order to reestablish a normal heart rate. We propose a technique that is a combination of biphasic shocks applied with a four-electrode system rather than the standard two-electrode system. We use a numerical model of a one-dimensional ring of cardiac tissue in order to test and evaluate the benefit of this technique. We compare three different shock protocols, namely a monophasic and two types of biphasic shocks. The results obtained by using a four-electrode system are compared quantitatively with those obtained with the standard two-electrode system. We find that a huge reduction in defibrillation threshold is achieved with the four-electrode system. For the most efficient protocol (asymmetric biphasic), we obtain a reduction in excess of 80% in the energy required for a defibrillation success rate of 90%. The mechanisms of successful defibrillation are also analyzed. This reveals that the advantage of asymmetric biphasic shocks with four electrodes lies in the duration of the cathodal and anodal phase of the shock.
Liu, Hu; Su, Rong-jia; Wu, Min-jie; Zhang, Yi; Qiu, Xiang-jun; Feng, Jian-gang; Xie, Ting; Lu, Shu-liang
2012-06-01
To form a wound information management scheme with objectivity, standardization, and convenience by means of wound information management system. A wound information management system was set up with the acquisition terminal, the defined wound description, the data bank, and related softwares. The efficacy of this system was evaluated in clinical practice. The acquisition terminal was composed of the third generation mobile phone and the software. It was feasible to get access to the wound information, including description, image, and therapeutic plan from the data bank by mobile phone. During 4 months, a collection of a total of 232 wound treatment information was entered, and accordingly standardized data of 38 patients were formed automatically. This system can provide standardized wound information management by standardized techniques of acquisition, transmission, and storage of wound information. It can be used widely in hospitals, especially primary medical institutions. Data resource of the system makes it possible for epidemiological study with large sample size in future.
Determination of plutonium in spent nuclear fuel using high resolution X-ray
McIntosh, Kathryn G.; Reilly, Sean D.; Havrilla, George J.
2015-05-30
Characterization of Pu is an essential aspect of safeguards operations at nuclear fuel reprocessing facilities. A novel analysis technique called hiRX (high resolution X-ray) has been developed for the direct measurement of Pu in spent nuclear fuel dissolver solutions. hiRX is based on monochromatic wavelength dispersive X-ray fluorescence (MWDXRF), which provides enhanced sensitivity and specificity compared with conventional XRF techniques. A breadboard setup of the hiRX instrument was calibrated using spiked surrogate spent fuel (SSF) standards prepared as dried residues. Samples of actual spent fuel were utilized to evaluate the performance of the hiRX. The direct detection of just 39more » ng of Pu is demonstrated. Initial quantitative results, with error of 4–27% and precision of 2% relative standard deviation (RSD), were obtained for spent fuel samples. The limit of detection for Pu (100 s) within an excitation spot of 200 μm diameter was 375 pg. This study demonstrates the potential for the hiRX technique to be utilized for the rapid, accurate, and precise determination of Pu. Moreover, the results highlight the analytical capability of hiRX for other applications requiring sensitive and selective nondestructive analyses.« less
Martínez-Torrecuadrada, Jorge L.; Lázaro, Beatriz; Rodriguez, José F.; Casal, J. Ignacio
2000-01-01
The routine technique for detecting antibodies specific to infectious bursal disease virus (IBDV) is a serological evaluation by enzyme-linked immunosorbent assay (ELISA) with preparations of whole virions as the antigens. To avoid using complete virus in the standard technique, we have developed two new antigens through the expression of the VPX and VP3 genes in insect cells. VPX and especially VP3 were expressed at high levels in insect cells and simple to purify. The immunogenicity of both proteins was similar to that of the native virus. VPX was able to elicit neutralizing antibodies but VP3 was not. Purified VPX and VP3 were tested in an indirect ELISA with more than 300 chicken sera. There was an excellent correlation between the results of the ELISA using VPX and those of the two commercial kits. VP3 did not perform as well as VPX, and the linear correlation was significantly lower. A comparison with the standard reference technique, seroneutralization, showed that the indirect ELISA was more sensitive. Therefore, VPX-based ELISA is a good alternative to conventional ELISAs that use whole virions. PMID:10882666
Martínez-Torrecuadrada, J L; Lázaro, B; Rodriguez, J F; Casal, J I
2000-07-01
The routine technique for detecting antibodies specific to infectious bursal disease virus (IBDV) is a serological evaluation by enzyme-linked immunosorbent assay (ELISA) with preparations of whole virions as the antigens. To avoid using complete virus in the standard technique, we have developed two new antigens through the expression of the VPX and VP3 genes in insect cells. VPX and especially VP3 were expressed at high levels in insect cells and simple to purify. The immunogenicity of both proteins was similar to that of the native virus. VPX was able to elicit neutralizing antibodies but VP3 was not. Purified VPX and VP3 were tested in an indirect ELISA with more than 300 chicken sera. There was an excellent correlation between the results of the ELISA using VPX and those of the two commercial kits. VP3 did not perform as well as VPX, and the linear correlation was significantly lower. A comparison with the standard reference technique, seroneutralization, showed that the indirect ELISA was more sensitive. Therefore, VPX-based ELISA is a good alternative to conventional ELISAs that use whole virions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McIntosh, Kathryn G.; Reilly, Sean D.; Havrilla, George J.
Characterization of Pu is an essential aspect of safeguards operations at nuclear fuel reprocessing facilities. A novel analysis technique called hiRX (high resolution X-ray) has been developed for the direct measurement of Pu in spent nuclear fuel dissolver solutions. hiRX is based on monochromatic wavelength dispersive X-ray fluorescence (MWDXRF), which provides enhanced sensitivity and specificity compared with conventional XRF techniques. A breadboard setup of the hiRX instrument was calibrated using spiked surrogate spent fuel (SSF) standards prepared as dried residues. Samples of actual spent fuel were utilized to evaluate the performance of the hiRX. The direct detection of just 39more » ng of Pu is demonstrated. Initial quantitative results, with error of 4–27% and precision of 2% relative standard deviation (RSD), were obtained for spent fuel samples. The limit of detection for Pu (100 s) within an excitation spot of 200 μm diameter was 375 pg. This study demonstrates the potential for the hiRX technique to be utilized for the rapid, accurate, and precise determination of Pu. Moreover, the results highlight the analytical capability of hiRX for other applications requiring sensitive and selective nondestructive analyses.« less
A new approach to large area microchannel plate manufacture
NASA Technical Reports Server (NTRS)
1986-01-01
Methods of manufacture of twisted single elements as the base for producing microchannel plates (MCP) are discussed. Initial evaluations validated the off-axis channel concept and no technological roadblocks were identified which would prevent fabrication of high gain, high spatial resolution, large format MCP's using this technique. The first MP's have operated at stable gains of 3 million with pulse height resolution superior to results obtained by standard chevron MCP's.
ERIC Educational Resources Information Center
Mazza, M.; Di Rienzo, A.; Costagliola, C.; Roncone, R.; Casacchia, M.; Ricci, A.; Galzio, R.J.
2004-01-01
Based on the observation of the course of callosal fibres and of their artero-venous support as appearing in a microanatomic study, the Authors propose a variant of standard callosotomy procedure by the introduction of the transverse section of callosal fibres. This technique would allow the surgeon to spare a larger number of callosal fibres by…
Application of automobile emission control technology to light piston aircraft engines
NASA Technical Reports Server (NTRS)
Tripp, D.; Kittredge, G.
1976-01-01
The possibility was evaluated for achieving the EPA Standards for HC and CO emissions through the use of air-fuel ratio enleanment at selected power modes combined with improved air-fuel mixture preparation, and in some cases improved cooling. Air injection was also an effective approach for the reduction of HC and CO, particularly when combined with exhaust heat conservation techniques such as exhaust port liners.
Thermal control of power supplies with electronic packaging techniques. [using low cost heat pipes
NASA Technical Reports Server (NTRS)
1977-01-01
The integration of low-cost commercial heat pipes in the design of a NASA candidate standard modular power supply with a 350 watt output resulted in a 44% weight reduction. Part temperatures were also appreciably reduced, increasing the environmental capability of the unit. A complete 350- watt modular power converter was built and tested to evaluate thermal performance of the redesigned supply.
Performance evaluation of digital phase-locked loops for advanced deep space transponders
NASA Technical Reports Server (NTRS)
Nguyen, T. M.; Hinedi, S. M.; Yeh, H.-G.; Kyriacou, C.
1994-01-01
The performances of the digital phase-locked loops (DPLL's) for the advanced deep-space transponders (ADT's) are investigated. DPLL's considered in this article are derived from the analog phase-locked loop, which is currently employed by the NASA standard deep space transponder, using S-domain to Z-domain mapping techniques. Three mappings are used to develop digital approximations of the standard deep space analog phase-locked loop, namely the bilinear transformation (BT), impulse invariant transformation (IIT), and step invariant transformation (SIT) techniques. The performance in terms of the closed loop phase and magnitude responses, carrier tracking jitter, and response of the loop to the phase offset (the difference between in incoming phase and reference phase) is evaluated for each digital approximation. Theoretical results of the carrier tracking jitter for command-on and command-off cases are then validated by computer simulation. Both theoretical and computer simulation results show that at high sampling frequency, the DPLL's approximated by all three transformations have the same tracking jitter. However, at low sampling frequency, the digital approximation using BT outperforms the others. The minimum sampling frequency for adequate tracking performance is determined for each digital approximation of the analog loop. In addition, computer simulation shows that the DPLL developed by BT provides faster response to the phase offset than IIT and SIT.
Evaluation of MRI sequences for quantitative T1 brain mapping
NASA Astrophysics Data System (ADS)
Tsialios, P.; Thrippleton, M.; Glatz, A.; Pernet, C.
2017-11-01
T1 mapping constitutes a quantitative MRI technique finding significant application in brain imaging. It allows evaluation of contrast uptake, blood perfusion, volume, providing a more specific biomarker of disease progression compared to conventional T1-weighted images. While there are many techniques for T1-mapping there is a wide range of reported T1-values in tissues, raising the issue of protocols reproducibility and standardization. The gold standard for obtaining T1-maps is based on acquiring IR-SE sequence. Widely used alternative sequences are IR-SE-EPI, VFA (DESPOT), DESPOT-HIFI and MP2RAGE that speed up scanning and fitting procedures. A custom MRI phantom was used to assess the reproducibility and accuracy of the different methods. All scans were performed using a 3T Siemens Prisma scanner. The acquired data processed using two different codes. The main difference was observed for VFA (DESPOT) which grossly overestimated T1 relaxation time by 214 ms [126 270] compared to the IR-SE sequence. MP2RAGE and DESPOT-HIFI sequences gave slightly shorter time than IR-SE (~20 to 30ms) and can be considered as alternative and time-efficient methods for acquiring accurate T1 maps of the human brain, while IR-SE-EPI gave identical result, at a cost of a lower image quality.
Synthesis and characterization of cellulose acetate from rice husk: eco-friendly condition.
Das, Archana M; Ali, Abdul A; Hazarika, Manash P
2014-11-04
Cellulose acetate was synthesized from rice husk by using a simple, efficient, cost-effective and solvent-free method. Cellulose was isolated from rice husk (RH) using standard pretreatment method with dilute alkaline and acid solutions and bleaching with 2% H2O2. Cellulose acetate (CA) was synthesized successfully with the yield of 66% in presence of acetic anhydride and iodine as a catalyst in eco-friendly solvent-free conditions. The reaction parameters were standardized at 80 °C for 300 min and the optimum results were taken for further study. The extent of acetylation was evaluated from % yield and the degree of substitution (DS), which was determined by (1)H NMR and titrimetrically. The synthesized products were characterized with the help modern analytical techniques like FT-IR, (1)H NMR, XRD, etc. and the thermal behavior was evaluated by TGA and DSC thermograms. Copyright © 2014 Elsevier Ltd. All rights reserved.
Evaluation of Information Leakage from Cryptographic Hardware via Common-Mode Current
NASA Astrophysics Data System (ADS)
Hayashi, Yu-Ichi; Homma, Naofumi; Mizuki, Takaaki; Sugawara, Takeshi; Kayano, Yoshiki; Aoki, Takafumi; Minegishi, Shigeki; Satoh, Akashi; Sone, Hideaki; Inoue, Hiroshi
This paper presents a possibility of Electromagnetic (EM) analysis against cryptographic modules outside their security boundaries. The mechanism behind the information leakage is explained from the view point of Electromagnetic Compatibility: electric fluctuation released from cryptographic modules can conduct to peripheral circuits based on ground bounce, resulting in radiation. We demonstrate the consequence of the mechanism through experiments where the ISO/IEC standard block cipher AES (Advanced Encryption Standard) is implemented on an FPGA board and EM radiations from power and communication cables are measured. Correlation Electromagnetic Analysis (CEMA) is conducted in order to evaluate the information leakage. The experimental results show that secret keys are revealed even though there are various disturbing factors such as voltage regulators and AC/DC converters between the target module and the measurement points. We also discuss information-suppression techniques as electrical-level countermeasures against such CEMAs.
Place, Benjamin J
2017-05-01
To address community needs, the National Institute of Standards and Technology has developed a candidate Standard Reference Material (SRM) for infant/adult nutritional formula based on milk and whey protein concentrates with isolated soy protein called SRM 1869 Infant/Adult Nutritional Formula. One major component of this candidate SRM is the fatty acid content. In this study, multiple extraction techniques were evaluated to quantify the fatty acids in this new material. Extraction methods that were based on lipid extraction followed by transesterification resulted in lower mass fraction values for all fatty acids than the values measured by methods utilizing in situ transesterification followed by fatty acid methyl ester extraction (ISTE). An ISTE method, based on the identified optimal parameters, was used to determine the fatty acid content of the new infant/adult nutritional formula reference material.
Recent Advances in Techniques for Hyperspectral Image Processing
NASA Technical Reports Server (NTRS)
Plaza, Antonio; Benediktsson, Jon Atli; Boardman, Joseph W.; Brazile, Jason; Bruzzone, Lorenzo; Camps-Valls, Gustavo; Chanussot, Jocelyn; Fauvel, Mathieu; Gamba, Paolo; Gualtieri, Anthony;
2009-01-01
Imaging spectroscopy, also known as hyperspectral imaging, has been transformed in less than 30 years from being a sparse research tool into a commodity product available to a broad user community. Currently, there is a need for standardized data processing techniques able to take into account the special properties of hyperspectral data. In this paper, we provide a seminal view on recent advances in techniques for hyperspectral image processing. Our main focus is on the design of techniques able to deal with the highdimensional nature of the data, and to integrate the spatial and spectral information. Performance of the discussed techniques is evaluated in different analysis scenarios. To satisfy time-critical constraints in specific applications, we also develop efficient parallel implementations of some of the discussed algorithms. Combined, these parts provide an excellent snapshot of the state-of-the-art in those areas, and offer a thoughtful perspective on future potentials and emerging challenges in the design of robust hyperspectral imaging algorithms
Tenório, Josceli Maria; Hummel, Anderson Diniz; Cohrs, Frederico Molina; Sdepanian, Vera Lucia; Pisa, Ivan Torres; de Fátima Marin, Heimar
2013-01-01
Background Celiac disease (CD) is a difficult-to-diagnose condition because of its multiple clinical presentations and symptoms shared with other diseases. Gold-standard diagnostic confirmation of suspected CD is achieved by biopsying the small intestine. Objective To develop a clinical decision–support system (CDSS) integrated with an automated classifier to recognize CD cases, by selecting from experimental models developed using intelligence artificial techniques. Methods A web-based system was designed for constructing a retrospective database that included 178 clinical cases for training. Tests were run on 270 automated classifiers available in Weka 3.6.1 using five artificial intelligence techniques, namely decision trees, Bayesian inference, k-nearest neighbor algorithm, support vector machines and artificial neural networks. The parameters evaluated were accuracy, sensitivity, specificity and area under the ROC curve (AUC). AUC was used as a criterion for selecting the CDSS algorithm. A testing database was constructed including 38 clinical CD cases for CDSS evaluation. The diagnoses suggested by CDSS were compared with those made by physicians during patient consultations. Results The most accurate method during the training phase was the averaged one-dependence estimator (AODE) algorithm (a Bayesian classifier), which showed accuracy 80.0%, sensitivity 0.78, specificity 0.80 and AUC 0.84. This classifier was integrated into the web-based decision–support system. The gold-standard validation of CDSS achieved accuracy of 84.2% and k = 0.68 (p < 0.0001) with good agreement. The same accuracy was achieved in the comparison between the physician’s diagnostic impression and the gold standard k = 0. 64 (p < 0.0001). There was moderate agreement between the physician’s diagnostic impression and CDSS k = 0.46 (p = 0.0008). Conclusions The study results suggest that CDSS could be used to help in diagnosing CD, since the algorithm tested achieved excellent accuracy in differentiating possible positive from negative CD diagnoses. This study may contribute towards developing of a computer-assisted environment to support CD diagnosis. PMID:21917512
Tenório, Josceli Maria; Hummel, Anderson Diniz; Cohrs, Frederico Molina; Sdepanian, Vera Lucia; Pisa, Ivan Torres; de Fátima Marin, Heimar
2011-11-01
Celiac disease (CD) is a difficult-to-diagnose condition because of its multiple clinical presentations and symptoms shared with other diseases. Gold-standard diagnostic confirmation of suspected CD is achieved by biopsying the small intestine. To develop a clinical decision-support system (CDSS) integrated with an automated classifier to recognize CD cases, by selecting from experimental models developed using intelligence artificial techniques. A web-based system was designed for constructing a retrospective database that included 178 clinical cases for training. Tests were run on 270 automated classifiers available in Weka 3.6.1 using five artificial intelligence techniques, namely decision trees, Bayesian inference, k-nearest neighbor algorithm, support vector machines and artificial neural networks. The parameters evaluated were accuracy, sensitivity, specificity and area under the ROC curve (AUC). AUC was used as a criterion for selecting the CDSS algorithm. A testing database was constructed including 38 clinical CD cases for CDSS evaluation. The diagnoses suggested by CDSS were compared with those made by physicians during patient consultations. The most accurate method during the training phase was the averaged one-dependence estimator (AODE) algorithm (a Bayesian classifier), which showed accuracy 80.0%, sensitivity 0.78, specificity 0.80 and AUC 0.84. This classifier was integrated into the web-based decision-support system. The gold-standard validation of CDSS achieved accuracy of 84.2% and k=0.68 (p<0.0001) with good agreement. The same accuracy was achieved in the comparison between the physician's diagnostic impression and the gold standard k=0. 64 (p<0.0001). There was moderate agreement between the physician's diagnostic impression and CDSS k=0.46 (p=0.0008). The study results suggest that CDSS could be used to help in diagnosing CD, since the algorithm tested achieved excellent accuracy in differentiating possible positive from negative CD diagnoses. This study may contribute towards developing of a computer-assisted environment to support CD diagnosis. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Obaidi, Leath Al; Mahlich, Jörg
2015-01-01
There are several methodologies that can be used for evaluating patients' perception of their quality of life. Most commonly, utilities are directly elicited by means of either the time-trade-off or the standard-gamble method. In both methods, risk attitudes determine the quality of life values. Quality of life values among 31 Austrian undergraduate students were elicited by means of the standard gamble approach. The impact of several variables such as gender, side job, length of study, and living arrangements on the quality of life were identified using different types of regression techniques (ordinary least squares, generalized linear model, Betafit). Significant evidence was found that females are associated with a higher quality of life in all specifications of our estimations. The observed gender differences in quality of life can be attributed to a higher degree of risk aversion of women. A higher risk aversion leads to a higher valuation of given health states and a potential gender bias in health economic evaluations. This result could have implications for health policy planners when it comes to budget allocation decisions.
Weber, Klaus; Mowat, Vasanthi; Hartmann, Elke; Razinger, Tanja; Chevalier, Hans-Jörg; Blumbach, Kai; Green, Owen P.; Kaiser, Stefan; Corney, Stephen; Jackson, Ailsa; Casadesus, Agustin
2011-01-01
Many variables may affect the outcome of continuous infusion studies. The results largely depend on the experience of the laboratory performing these studies, the technical equipment used, the choice of blood vessels and hence the surgical technique as well the quality of pathological evaluation. The latter is of major interest due to the fact that the pathologist is not involved until necropsy in most cases, i.e. not dealing with the complicated surgical or in-life procedures of this study type. The technique of tissue sampling during necropsy and the histology processing procedures may influence the tissues presented for evaluation, hence the pathologist may be a source of misinterpretation. Therefore, ITO proposes a tissue sampling procedure and a standard nomenclature for pathological lesions for all sites and tissues in contact with the port-access and/or catheter system. PMID:22272050
Hopf, Barbara; Dutz, Franz J; Bosselmann, Thomas; Willsch, Michael; Koch, Alexander W; Roths, Johannes
2018-04-30
A new iterative matrix algorithm has been applied to improve the precision of temperature and force decoupling in multi-parameter FBG sensing. For the first time, this evaluation technique allows the integration of nonlinearities in the sensor's temperature characteristic and the temperature dependence of the sensor's force sensitivity. Applied to a sensor cable consisting of two FBGs in fibers with 80 µm and 125 µm cladding diameter installed in a 7 m-long coiled PEEK capillary, this technique significantly reduced the uncertainties in friction-compensated temperature measurements. In the presence of high friction-induced forces of up to 1.6 N the uncertainties in temperature evaluation were reduced from several degrees Celsius if using a standard linear matrix approach to less than 0.5°C if using the iterative matrix approach in an extended temperature range between -35°C and 125°C.
Probabilistic retinal vessel segmentation
NASA Astrophysics Data System (ADS)
Wu, Chang-Hua; Agam, Gady
2007-03-01
Optic fundus assessment is widely used for diagnosing vascular and non-vascular pathology. Inspection of the retinal vasculature may reveal hypertension, diabetes, arteriosclerosis, cardiovascular disease and stroke. Due to various imaging conditions retinal images may be degraded. Consequently, the enhancement of such images and vessels in them is an important task with direct clinical applications. We propose a novel technique for vessel enhancement in retinal images that is capable of enhancing vessel junctions in addition to linear vessel segments. This is an extension of vessel filters we have previously developed for vessel enhancement in thoracic CT scans. The proposed approach is based on probabilistic models which can discern vessels and junctions. Evaluation shows the proposed filter is better than several known techniques and is comparable to the state of the art when evaluated on a standard dataset. A ridge-based vessel tracking process is applied on the enhanced image to demonstrate the effectiveness of the enhancement filter.
NASA Technical Reports Server (NTRS)
Larson, T. J.; Schweikhard, W. G.
1974-01-01
A method for evaluating aircraft takeoff performance from brake release to air-phase height that requires fewer tests than conventionally required is evaluated with data for the XB-70 airplane. The method defines the effects of pilot technique on takeoff performance quantitatively, including the decrease in acceleration from drag due to lift. For a given takeoff weight and throttle setting, a single takeoff provides enough data to establish a standardizing relationship for the distance from brake release to any point where velocity is appropriate to rotation. The lower rotation rates penalized takeoff performance in terms of ground roll distance; the lowest observed rotation rate required a ground roll distance that was 19 percent longer than the highest. Rotations at the minimum rate also resulted in lift-off velocities that were approximately 5 knots lower than the highest rotation rate at any given lift-off distance.
[Evaluation and results of ablative therapies in prostate cancer].
Renard-Penna, R; Sanchez-Salas, R; Barret, E; Cosset, J M; de Vergie, S; Sapetti, J; Ingels, A; Gangi, A; Lang, H; Cathelineau, X
2017-11-01
To perform a state of the art about methods of evaluation and present results in ablative therapies for localized prostate cancer. A review of the scientific literature was performed in Medline database (http://www.ncbi.nlm.nih.gov) and Embase (http://www.embase.com) using different associations of keywords. Publications obtained were selected based on methodology, language and relevance. After selection, 102 articles were analysed. Analyse the results of ablative therapies is presently difficult considering the heterogeneity of indications, techniques and follow-up. However, results from the most recent and homogeneous studies are encouraging. Oncologically, postoperative biopsies (the most important criteria) are negative (without any tumor cells in the treated area) in 75 to 95%. Functionally, urinary and sexual pre-operative status is spared (or recovered early) in more than 90% of the patients treated. More and more studies underline also the correlation between the results and the technique used considering the volume of the gland and, moreover, the "index lesion" localization. The post-treatment pathological evaluation by biopsies (targeted with MRI or, perhaps in a near future, with innovative ultrasonography) is the corner stone of oncological evaluation of ablative therapies. Ongoing trials will allow to standardize the follow-up and determine the best indication and the best techniques in order to optimize oncological and functional results for each patient treated. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Real-time ultrasonic weld evaluation system
NASA Astrophysics Data System (ADS)
Katragadda, Gopichand; Nair, Satish; Liu, Harry; Brown, Lawrence M.
1996-11-01
Ultrasonic testing techniques are currently used as an alternative to radiography for detecting, classifying,and sizing weld defects, and for evaluating weld quality. Typically, ultrasonic weld inspections are performed manually, which require significant operator expertise and time. Thus, in recent years, the emphasis is to develop automated methods to aid or replace operators in critical weld inspections where inspection time, reliability, and operator safety are major issues. During this period, significant advances wee made in the areas of weld defect classification and sizing. Very few of these methods, however have found their way into the market, largely due to the lack of an integrated approach enabling real-time implementation. Also, not much research effort was directed in improving weld acceptance criteria. This paper presents an integrated system utilizing state-of-the-art techniques for a complete automation of the weld inspection procedure. The modules discussed include transducer tracking, classification, sizing, and weld acceptance criteria. Transducer tracking was studied by experimentally evaluating sonic and optical position tracking techniques. Details for this evaluation are presented. Classification is obtained using a multi-layer perceptron. Results from different feature extraction schemes, including a new method based on a combination of time and frequency-domain signal representations are given. Algorithms developed to automate defect registration and sizing are discussed. A fuzzy-logic acceptance criteria for weld acceptance is presented describing how this scheme provides improved robustness compared to the traditional flow-diagram standards.
The Accuracy of Four Impression-making Techniques in Angulated Implants Based on Vertical Gap
Saboury, Abolfazl; Neshandar Asli, Hamid; Dalili Kajan, Zahra
2017-01-01
Statement of the Problem: Precision of the impression taken from implant positions significantly determines accurate fit of implant-supported prostheses. An imprecise impression may produce prosthesis misfit. Purpose: This study aimed to evaluate the accuracy of four impression-making techniques for angulated implants by stereomicroscope through measuring the vertical marginal gaps between the cemented metal framework and the implant analog. Materials and Method: A definitive cast with two 15° mesially angulated implants served as the standard reference for making all the impressions and later for accuracy evaluation. Four groups of five samples were evaluated: (1) closed-tray snap-fit transfer, (2) open-tray nonsplinted impression coping, (3) metal splinted impression coping, and (4) fabricated acrylic resin transfer cap. A gold-palladium framework was fabricated over the angulated implant abutments, the fit of which was used as reference. The gaps between the metal framework and the implant analogs were measured in sample groups. Corresponding means for each technique and the definitive cast were compared by using ANOVA and post hoc tests. Results: The mean marginal gap was 38.16±0µm in definitive cast, 89±19.74µm in group 1, 78.66±20.63µm in group 2, 54.16±24.29µm in group 3, and 55.83±18.30µm in group 4. ANOVA revealed significant differences between the definitive cast and groups 1 and 2, but not with groups 3 and 4 (p< 0.05). Conclusion: Vertical gap measurements showed that metal splinted impression coping and fabricated acrylic resin transfer cap techniques produced quite more accurate impressions than closed-tray snap-fit transfer and open-tray nonsplinted impression coping techniques do. The fabricated acrylic resin transfer cap technique seems to be a reliable impression-making method. PMID:29201973
Techniques for video compression
NASA Technical Reports Server (NTRS)
Wu, Chwan-Hwa
1995-01-01
In this report, we present our study on multiprocessor implementation of a MPEG2 encoding algorithm. First, we compare two approaches to implementing video standards, VLSI technology and multiprocessor processing, in terms of design complexity, applications, and cost. Then we evaluate the functional modules of MPEG2 encoding process in terms of their computation time. Two crucial modules are identified based on this evaluation. Then we present our experimental study on the multiprocessor implementation of the two crucial modules. Data partitioning is used for job assignment. Experimental results show that high speedup ratio and good scalability can be achieved by using this kind of job assignment strategy.
Elastography in Chronic Liver Disease: Modalities, Techniques, Limitations, and Future Directions
Srinivasa Babu, Aparna; Wells, Michael L.; Teytelboym, Oleg M.; Mackey, Justin E.; Miller, Frank H.; Yeh, Benjamin M.; Ehman, Richard L.
2016-01-01
Chronic liver disease has multiple causes, many of which are increasing in prevalence. The final common pathway of chronic liver disease is tissue destruction and attempted regeneration, a pathway that triggers fibrosis and eventual cirrhosis. Assessment of fibrosis is important not only for diagnosis but also for management, prognostic evaluation, and follow-up of patients with chronic liver disease. Although liver biopsy has traditionally been considered the reference standard for assessment of liver fibrosis, noninvasive techniques are the emerging focus in this field. Ultrasound-based elastography and magnetic resonance (MR) elastography are gaining popularity as the modalities of choice for quantifying hepatic fibrosis. These techniques have been proven superior to conventional cross-sectional imaging for evaluation of fibrosis, especially in the precirrhotic stages. Moreover, elastography has added utility in the follow-up of previously diagnosed fibrosis, the assessment of treatment response, evaluation for the presence of portal hypertension (spleen elastography), and evaluation of patients with unexplained portal hypertension. In this article, a brief overview is provided of chronic liver disease and the tools used for its diagnosis. Ultrasound-based elastography and MR elastography are explored in depth, including a brief glimpse into the evolution of elastography. Elastography is based on the principle of measuring tissue response to a known mechanical stimulus. Specific elastographic techniques used to exploit this principle include MR elastography and ultrasonography-based static or quasistatic strain imaging, one-dimensional transient elastography, point shear-wave elastography, and supersonic shear-wave elastography. The advantages, limitations, and pitfalls of each modality are emphasized. ©RSNA, 2016 PMID:27689833
In Search of Determinism-Sensitive Region to Avoid Artefacts in Recurrence Plots
NASA Astrophysics Data System (ADS)
Wendi, Dadiyorto; Marwan, Norbert; Merz, Bruno
As an effort to reduce parameter uncertainties in constructing recurrence plots, and in particular to avoid potential artefacts, this paper presents a technique to derive artefact-safe region of parameter sets. This technique exploits both deterministic (incl. chaos) and stochastic signal characteristics of recurrence quantification (i.e. diagonal structures). It is useful when the evaluated signal is known to be deterministic. This study focuses on the recurrence plot generated from the reconstructed phase space in order to represent many real application scenarios when not all variables to describe a system are available (data scarcity). The technique involves random shuffling of the original signal to destroy its original deterministic characteristics. Its purpose is to evaluate whether the determinism values of the original and the shuffled signal remain closely together, and therefore suggesting that the recurrence plot might comprise artefacts. The use of such determinism-sensitive region shall be accompanied by standard embedding optimization approaches, e.g. using indices like false nearest neighbor and mutual information, to result in a more reliable recurrence plot parameterization.
NASA Astrophysics Data System (ADS)
Karsi, Redouane; Zaim, Mounia; El Alami, Jamila
2017-07-01
Thanks to the development of the internet, a large community now has the possibility to communicate and express its opinions and preferences through multiple media such as blogs, forums, social networks and e-commerce sites. Today, it becomes clearer that opinions published on the web are a very valuable source for decision-making, so a rapidly growing field of research called “sentiment analysis” is born to address the problem of automatically determining the polarity (Positive, negative, neutral,…) of textual opinions. People expressing themselves in a particular domain often use specific domain language expressions, thus, building a classifier, which performs well in different domains is a challenging problem. The purpose of this paper is to evaluate the impact of domain for sentiment classification when using machine learning techniques. In our study three popular machine learning techniques: Support Vector Machines (SVM), Naive Bayes and K nearest neighbors(KNN) were applied on datasets collected from different domains. Experimental results show that Support Vector Machines outperforms other classifiers in all domains, since it achieved at least 74.75% accuracy with a standard deviation of 4,08.
Simultaneous measurement of the Young's modulus and the Poisson ratio of thin elastic layers.
Gross, Wolfgang; Kress, Holger
2017-02-07
The behavior of cells and tissue is greatly influenced by the mechanical properties of their environment. For studies on the interactions between cells and soft matrices, especially those applying traction force microscopy the characterization of the mechanical properties of thin substrate layers is essential. Various techniques to measure the elastic modulus are available. Methods to accurately measure the Poisson ratio of such substrates are rare and often imply either a combination of multiple techniques or additional equipment which is not needed for the actual biological studies. Here we describe a novel technique to measure both parameters, the Youngs's modulus and the Poisson ratio in a single experiment. The technique requires only a standard inverted epifluorescence microscope. As a model system, we chose cross-linked polyacrylamide and poly-N-isopropylacrylamide hydrogels which are known to obey Hooke's law. We place millimeter-sized steel spheres on the substrates which indent the surface. The data are evaluated using a previously published model which takes finite thickness effects of the substrate layer into account. We demonstrate experimentally for the first time that the application of the model allows the simultaneous determination of both the Young's modulus and the Poisson ratio. Since the method is easy to adapt and comes without the need of special equipment, we envision the technique to become a standard tool for the characterization of substrates for a wide range of investigations of cell and tissue behavior in various mechanical environments as well as other samples, including biological materials.
Description of MSFC engineering photographic analysis
NASA Technical Reports Server (NTRS)
Earle, Jim; Williams, Frank
1988-01-01
Utilizing a background that includes development of basic launch and test photographic coverage and analysis procedures, the MSFC Photographic Evaluation Group has built a body of experience that enables it to effectively satisfy MSFC's engineering photographic analysis needs. Combining the basic soundness of reliable, proven techniques of the past with the newer technical advances of computers and computer-related devices, the MSFC Photo Evaluation Group is in a position to continue to provide photo and video analysis service center-wide and NASA-wide to supply an improving photo analysis product to meet the photo evaluation needs of the future; and to provide new standards in the state-of-the-art of photo analysis of dynamic events.
Price, Travis K.; Dune, Tanaka; Hilt, Evann E.; Thomas-White, Krystal J.; Kliethermes, Stephanie; Brincat, Cynthia; Brubaker, Linda; Wolfe, Alan J.
2016-01-01
Enhanced quantitative urine culture (EQUC) detects live microorganisms in the vast majority of urine specimens reported as “no growth” by the standard urine culture protocol. Here, we evaluated an expanded set of EQUC conditions (expanded-spectrum EQUC) to identify an optimal version that provides a more complete description of uropathogens in women experiencing urinary tract infection (UTI)-like symptoms. One hundred fifty adult urogynecology patient-participants were characterized using a self-completed validated UTI symptom assessment (UTISA) questionnaire and asked “Do you feel you have a UTI?” Women responding negatively were recruited into the no-UTI cohort, while women responding affirmatively were recruited into the UTI cohort; the latter cohort was reassessed with the UTISA questionnaire 3 to 7 days later. Baseline catheterized urine samples were plated using both standard urine culture and expanded-spectrum EQUC protocols: standard urine culture inoculated at 1 μl onto 2 agars incubated aerobically; expanded-spectrum EQUC inoculated at three different volumes of urine onto 7 combinations of agars and environments. Compared to expanded-spectrum EQUC, standard urine culture missed 67% of uropathogens overall and 50% in participants with severe urinary symptoms. Thirty-six percent of participants with missed uropathogens reported no symptom resolution after treatment by standard urine culture results. Optimal detection of uropathogens could be achieved using the following: 100 μl of urine plated onto blood (blood agar plate [BAP]), colistin-nalidixic acid (CNA), and MacConkey agars in 5% CO2 for 48 h. This streamlined EQUC protocol achieved 84% uropathogen detection relative to 33% detection by standard urine culture. The streamlined EQUC protocol improves detection of uropathogens that are likely relevant for symptomatic women, giving clinicians the opportunity to receive additional information not currently reported using standard urine culture techniques. PMID:26962083
Imaging biomarkers in liver fibrosis.
Berzigotti, A; França, M; Martí-Aguado, D; Martí-Bonmatí, L
There is a need for early identification of patients with chronic liver diseases due to their increasing prevalence and morbidity-mortality. The degree of liver fibrosis determines the prognosis and therapeutic options in this population. Liver biopsy represents the reference standard for fibrosis staging. However, given its limitations and complications, different non-invasive methods have been developed recently for the in vivo quantification of fibrosis. Due to their precision and reliability, biomarkers' measurements derived from Ultrasound and Magnetic Resonance stand out. This article reviews the different acquisition techniques and image processing methods currently used in the evaluation of liver fibrosis, focusing on their diagnostic performance, applicability and clinical value. In order to properly interpret their results in the appropriate clinical context, it seems necessary to understand the techniques and their quality parameters, the standardization and validation of the measurement units and the quality control of the methodological problems. Copyright © 2017 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.
High-coverage quantitative proteomics using amine-specific isotopic labeling.
Melanson, Jeremy E; Avery, Steven L; Pinto, Devanand M
2006-08-01
Peptide dimethylation with isotopically coded formaldehydes was evaluated as a potential alternative to techniques such as the iTRAQ method for comparative proteomics. The isotopic labeling strategy and custom-designed protein quantitation software were tested using protein standards and then applied to measure proteins levels associated with Alzheimer's disease (AD). The method provided high accuracy (10% error), precision (14% RSD) and coverage (70%) when applied to the analysis of a standard solution of BSA by LC-MS/MS. The technique was then applied to measure protein abundance levels in brain tissue afflicted with AD relative to normal brain tissue. 2-D LC-MS analysis identified 548 unique proteins (p<0.05). Of these, 349 were quantified with two or more peptides that met the statistical criteria used in this study. Several classes of proteins exhibited significant changes in abundance. For example, elevated levels of antioxidant proteins and decreased levels of mitochondrial electron transport proteins were observed. The results demonstrate the utility of the labeling method for high-throughput quantitative analysis.
Assessment of and standardization for quantitative nondestructive test
NASA Technical Reports Server (NTRS)
Neuschaefer, R. W.; Beal, J. B.
1972-01-01
Present capabilities and limitations of nondestructive testing (NDT) as applied to aerospace structures during design, development, production, and operational phases are assessed. It will help determine what useful structural quantitative and qualitative data may be provided from raw materials to vehicle refurbishment. This assessment considers metal alloys systems and bonded composites presently applied in active NASA programs or strong contenders for future use. Quantitative and qualitative data has been summarized from recent literature, and in-house information, and presented along with a description of those structures or standards where the information was obtained. Examples, in tabular form, of NDT technique capabilities and limitations have been provided. NDT techniques discussed and assessed were radiography, ultrasonics, penetrants, thermal, acoustic, and electromagnetic. Quantitative data is sparse; therefore, obtaining statistically reliable flaw detection data must be strongly emphasized. The new requirements for reusable space vehicles have resulted in highly efficient design concepts operating in severe environments. This increases the need for quantitative NDT evaluation of selected structural components, the end item structure, and during refurbishment operations.
Macionis, Valdas
2013-01-09
Diagrammatic recording of finger joint angles by using two criss-crossed paper strips can be a quick substitute to the standard goniometry. As a preliminary step toward clinical validation of the diagrammatic technique, the current study employed healthy subjects and non-professional raters to explore whether reliability estimates of the diagrammatic goniometry are comparable with those of the standard procedure. The study included two procedurally different parts, which were replicated by assigning 24 medical students to act interchangeably as 12 subjects and 12 raters. A larger component of the study was designed to compare goniometers side-by-side in measurement of finger joint angles varying from subject to subject. In the rest of the study, the instruments were compared by parallel evaluations of joint angles similar for all subjects in a situation of simulated change of joint range of motion over time. The subjects used special guides to position the joints of their left ring finger at varying angles of flexion and extension. The obtained diagrams of joint angles were converted to numerical values by computerized measurements. The statistical approaches included calculation of appropriate intraclass correlation coefficients, standard errors of measurements, proportions of measurement differences of 5 or less degrees, and significant differences between paired observations. Reliability estimates were similar for both goniometers. Intra-rater and inter-rater intraclass correlation coefficients ranged from 0.69 to 0.93. The corresponding standard errors of measurements ranged from 2.4 to 4.9 degrees. Repeated measurements of a considerable number of raters fell within clinically non-meaningful 5 degrees of each other in proportions comparable with a criterion value of 0.95. Data collected with both instruments could be similarly interpreted in a simulated situation of change of joint range of motion over time. The paper goniometer and the standard goniometer can be used interchangeably by non-professional raters for evaluation of normal finger joints. The obtained results warrant further research to assess clinical performance of the paper strip technique.
2013-01-01
Background Diagrammatic recording of finger joint angles by using two criss-crossed paper strips can be a quick substitute to the standard goniometry. As a preliminary step toward clinical validation of the diagrammatic technique, the current study employed healthy subjects and non-professional raters to explore whether reliability estimates of the diagrammatic goniometry are comparable with those of the standard procedure. Methods The study included two procedurally different parts, which were replicated by assigning 24 medical students to act interchangeably as 12 subjects and 12 raters. A larger component of the study was designed to compare goniometers side-by-side in measurement of finger joint angles varying from subject to subject. In the rest of the study, the instruments were compared by parallel evaluations of joint angles similar for all subjects in a situation of simulated change of joint range of motion over time. The subjects used special guides to position the joints of their left ring finger at varying angles of flexion and extension. The obtained diagrams of joint angles were converted to numerical values by computerized measurements. The statistical approaches included calculation of appropriate intraclass correlation coefficients, standard errors of measurements, proportions of measurement differences of 5 or less degrees, and significant differences between paired observations. Results Reliability estimates were similar for both goniometers. Intra-rater and inter-rater intraclass correlation coefficients ranged from 0.69 to 0.93. The corresponding standard errors of measurements ranged from 2.4 to 4.9 degrees. Repeated measurements of a considerable number of raters fell within clinically non-meaningful 5 degrees of each other in proportions comparable with a criterion value of 0.95. Data collected with both instruments could be similarly interpreted in a simulated situation of change of joint range of motion over time. Conclusions The paper goniometer and the standard goniometer can be used interchangeably by non-professional raters for evaluation of normal finger joints. The obtained results warrant further research to assess clinical performance of the paper strip technique. PMID:23302419
Randelli, Pietro; Stoppani, Carlo Alberto; Zaolino, Carlo; Menon, Alessandra; Randelli, Filippo; Cabitza, Paolo
2017-07-01
Rotator cuff tear is a common finding in patients with painful, poorly functioning shoulders. The surgical management of this disorder has improved greatly and can now be fully arthroscopic. To evaluate clinical and radiological results of arthroscopic rotator cuff repair using 2 different techniques: single-row anchor fixation versus transosseous hardware-free suture repair. Randomized controlled trial; Level of evidence, 1. Sixty-nine patients with rotator cuff tears were enrolled: 35 patients were operated with metal anchors and 34 with standardized transosseous repair. The patients were clinically evaluated before surgery, during the 28 days after surgery, and at least 1 year after the operation by the use of validated rating scores (Constant score, QuickDASH, and numerical rating scale [NRS]). Final follow-up was obtained at more than 3 years by a QuickDASH evaluation to detect any difference from the previous follow-up. During the follow-up, rotator cuff integrity was determined through magnetic resonance imaging and was classified according to the 5 Sugaya categories. Patients operated with the transosseous technique had significantly less pain, especially from the 15th postoperative day: In the third week, the mean NRS value for the anchor group was 3.00 while that for transosseous group was 2.46 ( P = .02); in the fourth week, the values were 2.44 and 1.76, respectively ( P < .01). No differences in functional outcome were noted between the 2 groups at the final evaluation. In the evaluation of rotator cuff repair integrity, based on Sugaya magnetic resonance imaging classification, no significant difference was found between the 2 techniques in terms of retear rate ( P = .81). No significant differences were found between the 2 arthroscopic repair techniques in terms of functional and radiological results. However, postoperative pain decreased more quickly after the transosseous procedure, which therefore emerges as a possible improvement in the surgical repair of the rotator cuff. Registration: NCT01815177 ( ClinicalTrials.gov identifier).