Sample records for standard physiological monitoring

  1. Application of Acceleration Sensors in Physiological Experiments

    NASA Astrophysics Data System (ADS)

    Vavrinský, Erik; Moskal'vá, Daniela; Darříček, Martin; Donoval, Martin; Horínek, František; Popovič, Marían; Miklovič, Peter

    2014-09-01

    This paper illustrates a promising application of an accelerometer sensor in physiological research, we demonstrated use of accelerometers for monitoring the standard proband physical activity (PA) and also in special applications like respiration and mechanical heart activity, the so-called seismocardiography (SCG) monitoring, physiological activation monitoring and mechanomyography (MMG)

  2. A WBAN System for Ambulatory Monitoring of Physical Activity and Health Status: Applications and Challenges.

    PubMed

    Jovanov, E; Milenkovic, A; Otto, C; De Groen, P; Johnson, B; Warren, S; Taibi, G

    2005-01-01

    Recent technological advances in sensors, low-power integrated circuits, and wireless communications have enabled the design of low-cost, miniature, lightweight, intelligent physiological sensor platforms that can be seamlessly integrated into a body area network for health monitoring. Wireless body area networks (WBANs) promise unobtrusive ambulatory health monitoring for extended periods of time and near real-time updates of patients' medical records through the Internet. A number of innovative systems for health monitoring have recently been proposed. However, they typically rely on custom communication protocols and hardware designs, lacking generality and flexibility. The lack of standard platforms, system software support, and standards makes these systems expensive. Bulky sensors, high price, and frequent battery changes are all likely to limit user compliance. To address some of these challenges, we prototyped a WBAN utilizing a common off-the-shelf wireless sensor platform with a ZigBee-compliant radio interface and an ultra low-power microcontroller. The standard platform interfaces to custom sensor boards that are equipped with accelerometers for motion monitoring and a bioamplifier for electrocardiogram or electromyogram monitoring. Software modules for on-board processing, communication, and network synchronization have been developed using the TinyOS operating system. Although the initial WBAN prototype targets ambulatory monitoring of user activity, the developed sensors can easily be adapted to monitor other physiological parameters. In this paper, we discuss initial results, implementation challenges, and the need for standardization in this dynamic and promising research field.

  3. Recommendations for standards of monitoring during anaesthesia and recovery 2015: Association of Anaesthetists of Great Britain and Ireland.

    PubMed

    Checketts, M R; Alladi, R; Ferguson, K; Gemmell, L; Handy, J M; Klein, A A; Love, N J; Misra, U; Morris, C; Nathanson, M H; Rodney, G E; Verma, R; Pandit, J J

    2016-01-01

    This guideline updates and replaces the 4th edition of the AAGBI Standards of Monitoring published in 2007. The aim of this document is to provide guidance on the minimum standards for physiological monitoring of any patient undergoing anaesthesia or sedation under the care of an anaesthetist. The recommendations are primarily aimed at anaesthetists practising in the United Kingdom and Ireland. Minimum standards for monitoring patients during anaesthesia and in the recovery phase are included. There is also guidance on monitoring patients undergoing sedation and also during transfer of anaesthetised or sedated patients. There are new sections discussing the role of monitoring depth of anaesthesia, neuromuscular blockade and cardiac output. The indications for end-tidal carbon dioxide monitoring have been updated. © 2015 The Authors. Anaesthesia published by John Wiley & Sons Ltd on behalf of Association of Anaesthetists of Great Britain and Ireland.

  4. Physiological parameters monitoring of fire-fighters by means of a wearable wireless sensor system

    NASA Astrophysics Data System (ADS)

    Stelios, M.; Mitilineos, Stelios A.; Chatzistamatis, Panagiotis; Vassiliadis, Savvas; Primentas, Antonios; Kogias, Dimitris; Michailidis, Emmanouel T.; Rangoussi, Maria; Kurşun Bahadir, Senem; Atalay, Özgür; Kalaoğlu, Fatma; Sağlam, Yusuf

    2016-03-01

    Physiological parameter monitoring may be useful in many different groups of the population, such as infants, elderly people, athletes, soldiers, drivers, fire-fighters, police etc. This can provide a variety of information ranging from health status to operational readiness. In this article, we focus on the case of first responders and specifically fire-fighters. Firefighters can benefit from a physiological monitoring system that is used to extract multiple indications such as the present position, the possible life risk level, the stress level etc. This work presents a wearable wireless sensor network node, based on low cost, commercial-off- the-self (COTS) electronic modules, which can be easily attached on a standard fire-fighters’ uniform. Due to the low frequency wired interface between the selected electronic components, the proposed solution can be used as a basis for a textile system where all wired connections will be implemented by means of conductive yarn routing in the textile structure, while some of the standard sensors can be replaced by textile ones. System architecture is described in detail, while indicative samples of acquired signals are also presented.

  5. A multiparameter wearable physiologic monitoring system for space and terrestrial applications

    NASA Technical Reports Server (NTRS)

    Mundt, Carsten W.; Montgomery, Kevin N.; Udoh, Usen E.; Barker, Valerie N.; Thonier, Guillaume C.; Tellier, Arnaud M.; Ricks, Robert D.; Darling, Robert B.; Cagle, Yvonne D.; Cabrol, Nathalie A.; hide

    2005-01-01

    A novel, unobtrusive and wearable, multiparameter ambulatory physiologic monitoring system for space and terrestrial applications, termed LifeGuard, is presented. The core element is a wearable monitor, the crew physiologic observation device (CPOD), that provides the capability to continuously record two standard electrocardiogram leads, respiration rate via impedance plethysmography, heart rate, hemoglobin oxygen saturation, ambient or body temperature, three axes of acceleration, and blood pressure. These parameters can be digitally recorded with high fidelity over a 9-h period with precise time stamps and user-defined event markers. Data can be continuously streamed to a base station using a built-in Bluetooth RF link or stored in 32 MB of on-board flash memory and downloaded to a personal computer using a serial port. The device is powered by two AAA batteries. The design, laboratory, and field testing of the wearable monitors are described.

  6. Systematic review and meta-analysis of hemodynamic-directed feedback during cardiopulmonary resuscitation in cardiac arrest.

    PubMed

    Chopra, A S; Wong, N; Ziegler, C P; Morrison, L J

    2016-04-01

    Physiologic monitoring of resuscitative efforts during cardiac arrest is gaining in importance, as it provides a real-time window into the cellular physiology of patients. The aim of this review is to assess the quality of evidence surrounding the use of physiologic monitoring to guide cardiopulmonary resuscitation (CPR), and to examine whether the evidence demonstrates an improvement in patient outcome when comparing hemodynamic-directed CPR versus standard CPR. Studies were obtained through a search of the PubMed, Embase and Cochrane databases. Peer-reviewed randomized trials, case-control studies, systematic reviews, and cohort studies that titrated CPR to physiologic measures, compared results to standard CPR, and examined patient outcome were included. Six studies met inclusion criteria, with all studies conducted in animal populations. Four studies examined the effects of hemodynamic-directed CPR on survival, with 35/37 (94.6%) animals surviving in the hemodynamic-directed CPR groups and 12/35 (34.3%) surviving in the control groups (p<0.001). Two studies examined the effects of hemodynamic-directed CPR on ROSC, with 22/30 (73.3%) achieving ROSC in the hemodynamic-directed CPR group and 19/30 (63.3%) achieving ROSC in the control group (p=0.344). These results suggest a trend in survival from hemodynamic-directed CPR over standard CPR, however the small sample size and lack of human data make these results of limited value. Future human studies examining hemodynamic-directed CPR versus current CPR standards are needed to enhance our understanding of how to effectively use physiologic measures to improve resuscitation efforts and ultimately incorporate concrete targets into international resuscitation guidelines. Crown Copyright © 2016. Published by Elsevier Ireland Ltd. All rights reserved.

  7. Bioresorbable silicon electronics for transient spatiotemporal mapping of electrical activity from the cerebral cortex.

    PubMed

    Yu, Ki Jun; Kuzum, Duygu; Hwang, Suk-Won; Kim, Bong Hoon; Juul, Halvor; Kim, Nam Heon; Won, Sang Min; Chiang, Ken; Trumpis, Michael; Richardson, Andrew G; Cheng, Huanyu; Fang, Hui; Thomson, Marissa; Bink, Hank; Talos, Delia; Seo, Kyung Jin; Lee, Hee Nam; Kang, Seung-Kyun; Kim, Jae-Hwan; Lee, Jung Yup; Huang, Younggang; Jensen, Frances E; Dichter, Marc A; Lucas, Timothy H; Viventi, Jonathan; Litt, Brian; Rogers, John A

    2016-07-01

    Bioresorbable silicon electronics technology offers unprecedented opportunities to deploy advanced implantable monitoring systems that eliminate risks, cost and discomfort associated with surgical extraction. Applications include postoperative monitoring and transient physiologic recording after percutaneous or minimally invasive placement of vascular, cardiac, orthopaedic, neural or other devices. We present an embodiment of these materials in both passive and actively addressed arrays of bioresorbable silicon electrodes with multiplexing capabilities, which record in vivo electrophysiological signals from the cortical surface and the subgaleal space. The devices detect normal physiologic and epileptiform activity, both in acute and chronic recordings. Comparative studies show sensor performance comparable to standard clinical systems and reduced tissue reactivity relative to conventional clinical electrocorticography (ECoG) electrodes. This technology offers general applicability in neural interfaces, with additional potential utility in treatment of disorders where transient monitoring and modulation of physiologic function, implant integrity and tissue recovery or regeneration are required.

  8. Perceptions of seniors with heart failure regarding autonomous zero-effort monitoring of physiological parameters in the smart-home environment.

    PubMed

    Grace, Sherry L; Taherzadeh, Golnoush; Jae Chang, Isaac Sung; Boger, Jennifer; Arcelus, Amaya; Mak, Susanna; Chessex, Caroline; Mihailidis, Alex

    Technological advances are leading to the ability to autonomously monitor patient's health status in their own homes, to enable aging-in-place. To understand the perceptions of seniors with heart failure (HF) regarding smart-home systems to monitor their physiological parameters. In this qualitative study, HF outpatients were invited to a smart-home lab, where they completed a sequence of activities, during which the capacity of 5 autonomous sensing modalities was compared to gold standard measures. Afterwards, a semi-structured interview was undertaken. These were transcribed and analyzed using an interpretive-descriptive approach. Five themes emerged from the 26 interviews: (1) perceptions of technology, (2) perceived benefits of autonomous health monitoring, (3) disadvantages of autonomous monitoring, (4) lack of perceived need for continuous health monitoring, and (5) preferences for autonomous monitoring. Patient perception towards autonomous monitoring devices was positive, lending credence to zero-effort technology as a viable and promising approach. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Menopausal Hot Flashes and White Matter Hyperintensities

    PubMed Central

    Thurston, Rebecca C.; Aizenstein, Howard J.; Derby, Carol A.; Sejdić, Ervin; Maki, Pauline M.

    2015-01-01

    Objective Hot flashes are the classic menopausal symptom. Emerging data links hot flashes to cardiovascular disease (CVD) risk, yet how hot flashes are related to brain health is poorly understood. We examined the relationship between hot flashes - measured via physiologic monitor and self-report - and white matter hyperintensities (WMH) among midlife women. Methods Twenty midlife women ages 40-60 without clinical CVD, with their uterus and both ovaries, and not taking hormone therapy were recruited. Women underwent 24 hours of ambulatory physiologic and diary hot flash monitoring to quantify hot flashes; magnetic resonance imaging to assess WMH burden; 72 hours of actigraphy and questionnaires to quantify sleep; and a blood draw, questionnaires, and physical measures to quantify demographics and CVD risk factors. Test of a priori hypotheses regarding relations between physiologically-monitored and self-reported wake and sleep hot flashes and WMH were conducted in linear regression models. Results More physiologically-monitored hot flashes during sleep were associated with greater WMH, controlling for age, race, and body mass index [beta(standard error)=.0002 (.0001), p=.03]. Findings persisted controlling for sleep characteristics and additional CVD risk factors. No relations were observed for self-reported hot flashes. Conclusions More physiologically-monitored hot flashes during sleep were associated with greater WMH burden among midlife women free of clinical CVD. Results suggest that relations between hot flashes and CVD risk observed in the periphery may extend to the brain. Future work should consider the unique role of sleep hot flashes in brain health. PMID:26057822

  10. Monitoring of cerebral hemodynamics and oxygenation by continuous-wave optical spectroscopy during asphyxia in newborn piglets

    NASA Astrophysics Data System (ADS)

    Stankovic, Miljan R.; Fujii, Alan M.; Kirby, Debra; Boas, David A.; Ntziachristos, Vasilis; Stubblefield, Phillip G.

    1997-12-01

    The present study demonstrated that optical variables HbT and SmcO2 can be used to monitor changes in cerebral hemodynamics and oxygenation during asphyxia. Unfortunately none of the individual optical variables alone could be used to monitor changes in cerebral hemodynamics and oxygenation under a variety of possible clinical circumstances. However, all variables together, forming patterns unique to the commonly occurring physiological conditions, might potentially serve as a `silver standard' to aid interpretations of optical signals in clinical settings where `gold standard' techniques are not available, i.g. in the human fetus and neonate.

  11. Monitoring of cerebral hemodynamics and oxygenation by continuous-wave optical spectroscopy during asphyxia in newborn piglets

    NASA Astrophysics Data System (ADS)

    Stankovic, Miljan R.; Fujii, Alan M.; Kirby, Debra; Boas, David A.; Ntziachristos, Vasilis; Stubblefield, Phillip G.

    1998-01-01

    The present study demonstrated that optical variables HbT and SmcO2 can be used to monitor changes in cerebral hemodynamics and oxygenation during asphyxia. Unfortunately none of the individual optical variables alone could be used to monitor changes in cerebral hemodynamics and oxygenation under a variety of possible clinical circumstances. However, all variables together, forming patterns unique to the commonly occurring physiological conditions, might potentially serve as a `silver standard' to aid interpretations of optical signals in clinical settings where `gold standard' techniques are not available, i.g. in the human fetus and neonate.

  12. Effects of euthanasia on brain physiological activities monitored in real-time.

    PubMed

    Mayevsky, Avraham; Barbiro-Michaely, Efrat; Ligeti, Laszlo; MacLaughlin, Alan C

    2002-10-01

    Animal experimentation is terminated by the euthanasia procedure in order to avoid pain and minimize suffering. Very little is known about the real time physiological changes taking place in the brain of animals during the euthanasia. Since there is no way to evaluate the suffering of animals under euthanasia, it is assumed that objective physiological changes taking place could serve as a good way to compare various types of euthanasia procedures. In the present study we compared the effect of euthanasia induced by i. v. injection of concentrated KCL to that of Taxan T-61 (a standard mixture used by veterinarians). The responses of the cat brain were evaluated by monitoring the hemodynamic (CBF), metabolic (NADH redox state), electrical (EcoG) and extracellular ion levels, as an indicator to the ionic homeostasis.

  13. Monitoring of physiological parameters from multiple patients using wireless sensor network.

    PubMed

    Yuce, Mehmet R; Ng, Peng Choong; Khan, Jamil Y

    2008-10-01

    This paper presents a wireless sensor network system that has the capability to monitor physiological parameters from multiple patient bodies. The system uses the Medical Implant Communication Service band between the sensor nodes and a remote central control unit (CCU) that behaves as a base station. The CCU communicates with another network standard (the internet or a mobile network) for a long distance data transfer. The proposed system offers mobility to patients and flexibility to medical staff to obtain patient's physiological data on demand basis via Internet. A prototype sensor network including hardware, firmware and software designs has been implemented and tested. The developed system has been optimized for power consumption by having the nodes sleep when there is no communication via a bidirectional communication.

  14. A wireless medical monitoring over a heterogeneous sensor network.

    PubMed

    Yuce, Mehmet R; Ng, Peng Choong; Lee, Chin K; Khan, Jamil Y; Liu, Wentai

    2007-01-01

    This paper presents a heterogeneous sensor network system that has the capability to monitor physiological parameters from multiple patient bodies by means of different communication standards. The system uses the recently opened medical band called MICS (Medical Implant Communication Service) between the sensor nodes and a remote central control unit (CCU) that behaves as a base station. The CCU communicates with another network standard (the internet or a mobile network) for a long distance data transfer. The proposed system offers mobility to patients and flexibility to medical staff to obtain patient's physiological data on demand basis via Internet. A prototype sensor network including hardware, firmware and software designs has been implemented and tested by incorporating temperature and pulse rate sensors on nodes. The developed system has been optimized for power consumption by having the nodes sleep when there is no communication via a bidirectional communication.

  15. Medical smart textiles based on fiber optic technology: an overview.

    PubMed

    Massaroni, Carlo; Saccomandi, Paola; Schena, Emiliano

    2015-04-13

    The growing interest in the development of smart textiles for medical applications is driven by the aim to increase the mobility of patients who need a continuous monitoring of such physiological parameters. At the same time, the use of fiber optic sensors (FOSs) is gaining large acceptance as an alternative to traditional electrical and mechanical sensors for the monitoring of thermal and mechanical parameters. The potential impact of FOSs is related to their good metrological properties, their small size and their flexibility, as well as to their immunity from electromagnetic field. Their main advantage is the possibility to use textile based on fiber optic in a magnetic resonance imaging environment, where standard electronic sensors cannot be employed. This last feature makes FOSs suitable for monitoring biological parameters (e.g., respiratory and heartbeat monitoring) during magnetic resonance procedures. Research interest in combining FOSs and textiles into a single structure to develop wearable sensors is rapidly growing. In this review we provide an overview of the state-of-the-art of textiles, which use FOSs for monitoring of mechanical parameters of physiological interest. In particular we briefly describe the working principle of FOSs employed in this field and their relevant advantages and disadvantages. Also reviewed are their applications for the monitoring of mechanical parameters of physiological interest.

  16. Medical Smart Textiles Based on Fiber Optic Technology: An Overview

    PubMed Central

    Massaroni, Carlo; Saccomandi, Paola; Schena, Emiliano

    2015-01-01

    The growing interest in the development of smart textiles for medical applications is driven by the aim to increase the mobility of patients who need a continuous monitoring of such physiological parameters. At the same time, the use of fiber optic sensors (FOSs) is gaining large acceptance as an alternative to traditional electrical and mechanical sensors for the monitoring of thermal and mechanical parameters. The potential impact of FOSs is related to their good metrological properties, their small size and their flexibility, as well as to their immunity from electromagnetic field. Their main advantage is the possibility to use textile based on fiber optic in a magnetic resonance imaging environment, where standard electronic sensors cannot be employed. This last feature makes FOSs suitable for monitoring biological parameters (e.g., respiratory and heartbeat monitoring) during magnetic resonance procedures. Research interest in combining FOSs and textiles into a single structure to develop wearable sensors is rapidly growing. In this review we provide an overview of the state-of-the-art of textiles, which use FOSs for monitoring of mechanical parameters of physiological interest. In particular we briefly describe the working principle of FOSs employed in this field and their relevant advantages and disadvantages. Also reviewed are their applications for the monitoring of mechanical parameters of physiological interest. PMID:25871010

  17. Safety, reliability, and validity of a physiologic definition of bronchopulmonary dysplasia.

    PubMed

    Walsh, Michele C; Wilson-Costello, Deanna; Zadell, Arlene; Newman, Nancy; Fanaroff, Avroy

    2003-09-01

    Bronchopulmonary dysplasia (BPD) is the focus of many intervention trials, yet the outcome measure when based solely on oxygen administration may be confounded by differing criteria for oxygen administration between physicians. Thus, we wished to define BPD by a standardized oxygen saturation monitoring at 36 weeks corrected age, and compare this physiologic definition with the standard clinical definition of BPD based solely on oxygen administration. A total of 199 consecutive very low birthweight infants (VLBW, 501 to 1500 g birthweight) were assessed prospectively at 36+/-1 weeks corrected age. Neonates on positive pressure support or receiving >30% supplemental oxygen were assigned the outcome BPD. Those receiving < or =30% oxygen underwent a stepwise 2% reduction in supplemental oxygen to room air while under continuous observation and oxygen saturation monitoring. Outcomes of the test were "no BPD" (saturations > or =88% for 60 minutes) or "BPD" (saturation < 88%). At the conclusion of the test, all infants were returned to their baseline oxygen. Safety (apnea, bradycardia, increased oxygen use), inter-rater reliability, test-retest reliability, and validity of the physiologic definition vs the clinical definition were assessed. A total of 199 VLBW were assessed, of whom 45 (36%) were diagnosed with BPD by the clinical definition of oxygen use at 36 weeks corrected age. The physiologic definition identified 15 infants treated with oxygen who successfully passed the saturation monitoring test in room air. The physiologic definition diagnosed BPD in 30 (24%) of the cohort. All infants were safely studied. The test was highly reliable (inter-rater reliability, kappa=1.0; test-retest reliability, kappa=0.83) and highly correlated with discharge home in oxygen, length of hospital stay, and hospital readmissions in the first year of life. The physiologic definition of BPD is safe, feasible, reliable, and valid and improves the precision of the diagnosis of BPD. This may be of benefit in future multicenter clinical trials.

  18. Cardiopulmonary resuscitation quality and beyond: the need to improve real-time feedback and physiologic monitoring.

    PubMed

    Lin, Steve; Scales, Damon C

    2016-06-28

    High-quality cardiopulmonary resuscitation (CPR) has been shown to improve survival outcomes after cardiac arrest. The current standard in studies evaluating CPR quality is to measure CPR process measures-for example, chest compression rate, depth, and fraction. Published studies evaluating CPR feedback devices have yielded mixed results. Newer approaches that seek to optimize CPR by measuring physiological endpoints during the resuscitation may lead to individualized patient care and improved patient outcomes.

  19. A Method of High Throughput Monitoring Crop Physiology Using Chlorophyll Fluorescence and Multispectral Imaging.

    PubMed

    Wang, Heng; Qian, Xiangjie; Zhang, Lan; Xu, Sailong; Li, Haifeng; Xia, Xiaojian; Dai, Liankui; Xu, Liang; Yu, Jingquan; Liu, Xu

    2018-01-01

    We present a high throughput crop physiology condition monitoring system and corresponding monitoring method. The monitoring system can perform large-area chlorophyll fluorescence imaging and multispectral imaging. The monitoring method can determine the crop current condition continuously and non-destructively. We choose chlorophyll fluorescence parameters and relative reflectance of multispectral as the indicators of crop physiological status. Using tomato as experiment subject, the typical crop physiological stress, such as drought, nutrition deficiency and plant disease can be distinguished by the monitoring method. Furthermore, we have studied the correlation between the physiological indicators and the degree of stress. Besides realizing the continuous monitoring of crop physiology, the monitoring system and method provide the possibility of machine automatic diagnosis of the plant physiology. Highlights: A newly designed high throughput crop physiology monitoring system and the corresponding monitoring method are described in this study. Different types of stress can induce distinct fluorescence and spectral characteristics, which can be used to evaluate the physiological status of plants.

  20. A new wireless system for decentralised measurement of physiological parameters from shake flasks

    PubMed Central

    Vasala, Antti; Panula, Johanna; Bollók, Monika; Illmann, Lutz; Hälsig, Christian; Neubauer, Peter

    2006-01-01

    Background Shake flasks are widely used because of their low price and simple handling. Many researcher are, however, not aware of the physiological consequences of oxygen limitation and substrate overflow metabolism that occur in shake flasks. Availability of a wireless measuring system brings the possibilities for quality control and design of cultivation conditions. Results Here we present a new wireless solution for the measurement of pH and oxygen from shake flasks with standard sensors, which allows data transmission over a distance of more than 100 metres in laboratory environments. This new system was applied to monitoring of cultivation conditions in shake flasks. The at-time monitoring of the growth conditions became possible by simple means. Here we demonstrate that with typical protocols E. coli shake flask cultures run into severe oxygen limitation and the medium is strongly acidified. Additionally the strength of the new system is demonstrated by continuous monitoring of the oxygen level in methanol-fed Pichia pastoris shake flask cultures, which allows the optimisation of substrate feeding for preventing starvation or methanol overfeed. 40 % higher cell density was obtained by preventing starvation phases which occur in standard shake flask protocols by adding methanol when the respiration activity decreased in the cultures. Conclusion The here introduced wireless system can read parallel sensor data over long distances from shake flasks that are under vigorous shaking in cultivation rooms or closed incubators. The presented technology allows centralised monitoring of decentralised targets. It is useful for the monitoring of pH and dissolved oxygen in shake flask cultures. It is not limited to standard sensors, but can be easily adopted to new types of sensors and measurement places (e.g., new sensor points in large-scale bioreactors). PMID:16504107

  1. Physiological Parameter Monitoring from Optical Recordings with a Mobile Phone

    PubMed Central

    Scully, Christopher G.; Lee, Jinseok; Meyer, Joseph; Gorbach, Alexander M.; Granquist-Fraser, Domhnull; Mendelson, Yitzhak

    2012-01-01

    We show that a mobile phone can serve as an accurate monitor for several physiological variables, based on its ability to record and analyze the varying color signals of a fingertip placed in contact with its optical sensor. We confirm the accuracy of measurements of breathing rate, cardiac R-R intervals, and blood oxygen saturation, by comparisons to standard methods for making such measurements (respiration belts, ECGs, and pulse-oximeters, respectively). Measurement of respiratory rate uses a previously reported algorithm developed for use with a pulse-oximeter, based on amplitude and frequency modulation sequences within the light signal. We note that this technology can also be used with recently developed algorithms for detection of atrial fibrillation or blood loss. PMID:21803676

  2. Evolution of microbiological analytical methods for dairy industry needs

    PubMed Central

    Sohier, Danièle; Pavan, Sonia; Riou, Armelle; Combrisson, Jérôme; Postollec, Florence

    2014-01-01

    Traditionally, culture-based methods have been used to enumerate microbial populations in dairy products. Recent developments in molecular methods now enable faster and more sensitive analyses than classical microbiology procedures. These molecular tools allow a detailed characterization of cell physiological states and bacterial fitness and thus, offer new perspectives to integration of microbial physiology monitoring to improve industrial processes. This review summarizes the methods described to enumerate and characterize physiological states of technological microbiota in dairy products, and discusses the current deficiencies in relation to the industry’s needs. Recent studies show that Polymerase chain reaction-based methods can successfully be applied to quantify fermenting microbes and probiotics in dairy products. Flow cytometry and omics technologies also show interesting analytical potentialities. However, they still suffer from a lack of validation and standardization for quality control analyses, as reflected by the absence of performance studies and official international standards. PMID:24570675

  3. Evolution of microbiological analytical methods for dairy industry needs.

    PubMed

    Sohier, Danièle; Pavan, Sonia; Riou, Armelle; Combrisson, Jérôme; Postollec, Florence

    2014-01-01

    Traditionally, culture-based methods have been used to enumerate microbial populations in dairy products. Recent developments in molecular methods now enable faster and more sensitive analyses than classical microbiology procedures. These molecular tools allow a detailed characterization of cell physiological states and bacterial fitness and thus, offer new perspectives to integration of microbial physiology monitoring to improve industrial processes. This review summarizes the methods described to enumerate and characterize physiological states of technological microbiota in dairy products, and discusses the current deficiencies in relation to the industry's needs. Recent studies show that Polymerase chain reaction-based methods can successfully be applied to quantify fermenting microbes and probiotics in dairy products. Flow cytometry and omics technologies also show interesting analytical potentialities. However, they still suffer from a lack of validation and standardization for quality control analyses, as reflected by the absence of performance studies and official international standards.

  4. Continuous noninvasive monitoring in the neonatal ICU.

    PubMed

    Sahni, Rakesh

    2017-04-01

    Standard hemodynamic monitoring such as heart rate and systemic blood pressure may only provide a crude estimation of organ perfusion during neonatal intensive care. Pulse oximetry monitoring allows for continuous noninvasive monitoring of hemoglobin oxygenation and thus provides estimation of end-organ oxygenation. This review aims to provide an overview of pulse oximetry and discuss its current and potential clinical use during neonatal intensive care. Technological advances in continuous assessment of dynamic changes in systemic oxygenation with pulse oximetry during transition to extrauterine life and beyond provide additional details about physiological interactions among the key hemodynamic factors regulating systemic blood flow distribution along with the subtle changes that are frequently transient and undetectable with standard monitoring. Noninvasive real-time continuous systemic oxygen monitoring has the potential to serve as biomarkers for early-organ dysfunction, to predict adverse short-term and long-term outcomes in critically ill neonates, and to optimize outcomes. Further studies are needed to establish values predicting adverse outcomes and to validate targeted interventions to normalize abnormal values to improve outcomes.

  5. A Test Fixture for Simulating Human Limb Physiology and Soft Tissue Biomechanics

    DTIC Science & Technology

    1989-04-14

    Food and Drug Administration (FDA) has not promu!gated performance standards for vital signs monitors that determine blood pressure and heart rate...static char answer[] = "" double f~ttnun~pts, single, doubleit, triple; int single_ -leftover, doubleit I eftover , triple-Leftover; double sin

  6. Smart Vest: wearable multi-parameter remote physiological monitoring system.

    PubMed

    Pandian, P S; Mohanavelu, K; Safeer, K P; Kotresh, T M; Shakunthala, D T; Gopal, Parvati; Padaki, V C

    2008-05-01

    The wearable physiological monitoring system is a washable shirt, which uses an array of sensors connected to a central processing unit with firmware for continuously monitoring physiological signals. The data collected can be correlated to produce an overall picture of the wearer's health. In this paper, we discuss the wearable physiological monitoring system called 'Smart Vest'. The Smart Vest consists of a comfortable to wear vest with sensors integrated for monitoring physiological parameters, wearable data acquisition and processing hardware and remote monitoring station. The wearable data acquisition system is designed using microcontroller and interfaced with wireless communication and global positioning system (GPS) modules. The physiological signals monitored are electrocardiogram (ECG), photoplethysmogram (PPG), body temperature, blood pressure, galvanic skin response (GSR) and heart rate. The acquired physiological signals are sampled at 250samples/s, digitized at 12-bit resolution and transmitted wireless to a remote physiological monitoring station along with the geo-location of the wearer. The paper describes a prototype Smart Vest system used for remote monitoring of physiological parameters and the clinical validation of the data are also presented.

  7. Evaluating Sleep Disturbance: A Review of Methods

    NASA Technical Reports Server (NTRS)

    Smith, Roy M.; Oyung, R.; Gregory, K.; Miller, D.; Rosekind, M.; Rosekind, Mark R. (Technical Monitor)

    1996-01-01

    There are three general approaches to evaluating sleep disturbance in regards to noise: subjective, behavioral, and physiological. Subjective methods range from standardized questionnaires and scales to self-report measures designed for specific research questions. There are two behavioral methods that provide useful sleep disturbance data. One behavioral method is actigraphy, a motion detector that provides an empirical estimate of sleep quantity and quality. An actigraph, worn on the non-dominant wrist, provides a 24-hr estimate of the rest/activity cycle. The other method involves a behavioral response, either to a specific probe or stimuli or subject initiated (e.g., indicating wakefulness). The classic, gold standard for evaluating sleep disturbance is continuous physiological monitoring of brain, eye, and muscle activity. This allows detailed distinctions of the states and stages of sleep, awakenings, and sleep continuity. Physiological delta can be obtained in controlled laboratory settings and in natural environments. Current ambulatory physiological recording equipment allows evaluation in home and work settings. These approaches will be described and the relative strengths and limitations of each method will be discussed.

  8. A novel ultra-wideband 80 GHz FMCW radar system for contactless monitoring of vital signs.

    PubMed

    Wang, Siying; Pohl, Antje; Jaeschke, Timo; Czaplik, Michael; Köny, Marcus; Leonhardt, Steffen; Pohl, Nils

    2015-01-01

    In this paper an ultra-wideband 80 GHz FMCW-radar system for contactless monitoring of respiration and heart rate is investigated and compared to a standard monitoring system with ECG and CO(2) measurements as reference. The novel FMCW-radar enables the detection of the physiological displacement of the skin surface with submillimeter accuracy. This high accuracy is achieved with a large bandwidth of 10 GHz and the combination of intermediate frequency and phase evaluation. This concept is validated with a radar system simulation and experimental measurements are performed with different radar sensor positions and orientations.

  9. Comparing the effects of minimal handling protocols on the physiological parameters of preterm infants receiving exogenous surfactant therapy

    PubMed Central

    Cabral, Laura A.; Velloso, Marcelo

    2014-01-01

    Background The practice of minimal handling is recommended for preterm infants (PTIs). However, few studies have investigated the effects of this practice among these infants or the time needed to ensure greater physiological stability, especially after exogenous surfactant treatments. Objective The current study compared the effects of two protocols of minimal handling on the physiological variables of PTIs after surfactant therapy. Method An exploratory prospective observational study was performed with 40 PTIs weighing less than 1,500 g. The infants were divided into two groups and monitored for 72 hours. One group received the standard minimal handling procedure during the first 12 hours after surfactant therapy; the other group (i.e., the modified group) received minimal handling within 72 hours after surfactant therapy. Infant heart rate (HR), oxygen saturation, body temperature, and the adverse events associated with changes to these variables were monitored every 10 minutes. Results Significant between-group differences were not found with regard to the occurrence of the adverse events associated with physiological changes (p>0.05). Conclusion The practice of minimal handling among very low birth weight infants did not alter their physiological stability when performed either 12 or 72 hours after surfactant therapy. PMID:24839044

  10. Personal health records: mobile biosensors and smartphones for developing countries.

    PubMed

    Simon, Sternly K; Seldon, H Lee

    2012-01-01

    A target of telehealth is to maintain or improve the health of people outside the normal healthcare infrastructure. A modern paradigm in healthcare, and one which fits perfectly with telehealth, is "person self-monitoring", and this fits with the concept of "personal health record" (PHR). One factor in maintaining health is to monitor physiological parameters; this is of course especially important in people with chronic maladies such as diabetes or heart disease. Parameters to be monitored include blood pressure, pulse rate, temperature, weight, blood glucose, oxygen saturation, electrocardiogram (ECG), etc. So one task within telehealth would be to help monitor an individual's physiological parameters outside of healthcare institutions and store the results in a PHR in a way which is available, comprehensible and beneficial to the individual concerned and to healthcare providers. To date many approaches to this problem have been fragmented - emphasizing only part of the problem - or proprietary and not freely verifiable. We describe a framework to approach this task; it emphasizes the implementation of standards for data acquisition, storage and transmission in order to maximize the compatibility among disparate components, e.g. various PHR systems. Data from mobile biosensors is collected on a smartphone using the IEEE 11073 standard where possible; the data can be stored in a PHR on the phone (using standard formats) or can be converted in real-time into more useful information in the PHR, which is based on the International Classification for Primary Care (ICPC2e). The phone PHR data or information can be uploaded to a central online PHR using either the Wi-Fi or GSM transmission protocol together with the Continuity of Care Record message format (CCR, ASTM E2369).

  11. Physiology, intervention, and outcome: three critical questions about cerebral tissue oxygen saturation monitoring.

    PubMed

    Meng, Lingzhong; Gruenbaum, Shaun E; Dai, Feng; Wang, Tianlong

    2018-05-01

    The balance between cerebral tissue oxygen consumption and supply can be continuously assessed by cerebral tissue oxygen saturation (SctO2) monitor. A construct consisting of three sequential questions, targeting the physiology monitored, the intervention implemented, and the outcomes affected, is proposed to critically appraise this monitor. The impact of the SctO2-guided care on patient outcome was examined through a systematic literature search and meta-analysis. We concluded that the physiology monitored by SctO2 is robust and dynamic, fragile (prone to derangement), and adversely consequential when deranged. The inter-individual variability of SctO2 measurement advocates for an intervention threshold based on a relative, not absolute, change. The intra-individual variability has multiple determinants which is the foundation of intervention. A variety of therapeutic options are available; however, none are 100% efficacious in treating cerebral dys-oxygenation. The therapeutic efficacy likely depends on both an appropriate differential diagnosis and the functional status of the regulatory mechanisms of cerebral blood flow. Meta-analysis based on five randomized controlled trials suggested a reduced incidence of early postoperative cognitive decline after major surgeries (RR= 0.53; 95% CI: 0.33-0.87; I2 =82%; P=0.01). However, its effects on other neurocognitive outcomes remain unclear. These results need to be interpreted with caution due to the high risks of bias. Quality RCTs based on improved intervention protocols and standardized outcome assessment are warranted in the future.

  12. Incorporating High-Frequency Physiologic Data Using Computational Dictionary Learning Improves Prediction of Delayed Cerebral Ischemia Compared to Existing Methods.

    PubMed

    Megjhani, Murad; Terilli, Kalijah; Frey, Hans-Peter; Velazquez, Angela G; Doyle, Kevin William; Connolly, Edward Sander; Roh, David Jinou; Agarwal, Sachin; Claassen, Jan; Elhadad, Noemie; Park, Soojin

    2018-01-01

    Accurate prediction of delayed cerebral ischemia (DCI) after subarachnoid hemorrhage (SAH) can be critical for planning interventions to prevent poor neurological outcome. This paper presents a model using convolution dictionary learning to extract features from physiological data available from bedside monitors. We develop and validate a prediction model for DCI after SAH, demonstrating improved precision over standard methods alone. 488 consecutive SAH admissions from 2006 to 2014 to a tertiary care hospital were included. Models were trained on 80%, while 20% were set aside for validation testing. Modified Fisher Scale was considered the standard grading scale in clinical use; baseline features also analyzed included age, sex, Hunt-Hess, and Glasgow Coma Scales. An unsupervised approach using convolution dictionary learning was used to extract features from physiological time series (systolic blood pressure and diastolic blood pressure, heart rate, respiratory rate, and oxygen saturation). Classifiers (partial least squares and linear and kernel support vector machines) were trained on feature subsets of the derivation dataset. Models were applied to the validation dataset. The performances of the best classifiers on the validation dataset are reported by feature subset. Standard grading scale (mFS): AUC 0.54. Combined demographics and grading scales (baseline features): AUC 0.63. Kernel derived physiologic features: AUC 0.66. Combined baseline and physiologic features with redundant feature reduction: AUC 0.71 on derivation dataset and 0.78 on validation dataset. Current DCI prediction tools rely on admission imaging and are advantageously simple to employ. However, using an agnostic and computationally inexpensive learning approach for high-frequency physiologic time series data, we demonstrated that we could incorporate individual physiologic data to achieve higher classification accuracy.

  13. Efficient security mechanisms for mHealth applications using wireless body sensor networks.

    PubMed

    Sahoo, Prasan Kumar

    2012-01-01

    Recent technological advances in wireless communications and physiological sensing allow miniature, lightweight, ultra-low power, intelligent monitoring devices, which can be integrated into a Wireless Body Sensor Network (WBSN) for health monitoring. Physiological signals of humans such as heartbeats, temperature and pulse can be monitored from a distant location using tiny biomedical wireless sensors. Hence, it is highly essential to combine the ubiquitous computing with mobile health technology using wireless sensors and smart phones to monitor the well-being of chronic patients such as cardiac, Parkinson and epilepsy patients. Since physiological data of a patient are highly sensitive, maintaining its confidentiality is highly essential. Hence, security is a vital research issue in mobile health (mHealth) applications, especially if a patient has an embarrassing disease. In this paper a three tier security architecture for the mHealth application is proposed, in which light weight data confidentiality and authentication protocols are proposed to maintain the privacy of a patient. Moreover, considering the energy and hardware constraints of the wireless body sensors, low complexity data confidential and authentication schemes are designed. Performance evaluation of the proposed architecture shows that they can satisfy the energy and hardware limitations of the sensors and still can maintain the secure fabrics of the wireless body sensor networks. Besides, the proposed schemes can outperform in terms of energy consumption, memory usage and computation time over standard key establishment security scheme.

  14. Efficient Security Mechanisms for mHealth Applications Using Wireless Body Sensor Networks

    PubMed Central

    Sahoo, Prasan Kumar

    2012-01-01

    Recent technological advances in wireless communications and physiological sensing allow miniature, lightweight, ultra-low power, intelligent monitoring devices, which can be integrated into a Wireless Body Sensor Network (WBSN) for health monitoring. Physiological signals of humans such as heartbeats, temperature and pulse can be monitored from a distant location using tiny biomedical wireless sensors. Hence, it is highly essential to combine the ubiquitous computing with mobile health technology using wireless sensors and smart phones to monitor the well-being of chronic patients such as cardiac, Parkinson and epilepsy patients. Since physiological data of a patient are highly sensitive, maintaining its confidentiality is highly essential. Hence, security is a vital research issue in mobile health (mHealth) applications, especially if a patient has an embarrassing disease. In this paper a three tier security architecture for the mHealth application is proposed, in which light weight data confidentiality and authentication protocols are proposed to maintain the privacy of a patient. Moreover, considering the energy and hardware constraints of the wireless body sensors, low complexity data confidential and authentication schemes are designed. Performance evaluation of the proposed architecture shows that they can satisfy the energy and hardware limitations of the sensors and still can maintain the secure fabrics of the wireless body sensor networks. Besides, the proposed schemes can outperform in terms of energy consumption, memory usage and computation time over standard key establishment security scheme. PMID:23112734

  15. A mobile system for assessment of physiological response to posture transitions.

    PubMed

    Jovanov, Emil; Milosevic, Mladen; Milenković, Aleksandar

    2013-01-01

    Posture changes initiate a dynamic physiological response that can be used as an indicator of the overall health status. We introduce an inconspicuous mobile wellness monitoring system (imWell) that continuously assesses the dynamic physiological response to posture transitions during activities of daily living. imWell utilizes a Zephyr BioHarness 3 physiological monitor that continually reports heart activity and physical activity via Bluetooth to a personal device (e.g. smartphone). The personal device processes the reported activity data in real-time to recognize posture transitions from the accelerometer data and to characterize dynamic heart response to posture changes. It annotates, logs, and uploads the heart activity data to our mHealth server. In this paper we present algorithms for detection of posture transitions and heart activity characterization during a sit-to-stand transition. The proposed system was tested on seven healthy subjects performing a predefined protocol. The total average and standard deviation for sit-to-stand transition time is 2.7 ± 0.69 s, resulting in the change of heart rate of 27.36 ± 9.30 bpm (from 63.3 ± 9.02 bpm to 90.66 ± 10.09 bpm).

  16. Classification Models for Pulmonary Function using Motion Analysis from Phone Sensors.

    PubMed

    Cheng, Qian; Juen, Joshua; Bellam, Shashi; Fulara, Nicholas; Close, Deanna; Silverstein, Jonathan C; Schatz, Bruce

    2016-01-01

    Smartphones are ubiquitous, but it is unknown what physiological functions can be monitored at clinical quality. Pulmonary function is a standard measure of health status for cardiopulmonary patients. We have shown phone sensors can accurately measure walking patterns. Here we show that improved classification models can accurately measure pulmonary function, with sole inputs being sensor data from carried phones. Twenty-four cardiopulmonary patients performed six minute walk tests in pulmonary rehabilitation at a regional hospital. They carried smartphones running custom software recording phone motion. For every patient, every ten-second interval was correctly computed. The trained model perfectly computed the GOLD level 1/2/3, which is a standard categorization of pulmonary function as measured by spirometry. These results are encouraging towards field trials with passive monitors always running in the background. We expect patients can simply carry their phones during daily living, while supporting automatic computation ofpulmonary function for health monitoring.

  17. Enhancement of absorption and resistance of motion utilizing a multi-channel opto-electronic sensor to effectively monitor physiological signs during sport exercise

    NASA Astrophysics Data System (ADS)

    Alzahrani, Abdullah; Hu, Sijung; Azorin-Peris, Vicente; Barrett, Laura; Esliger, Dale; Hayes, Matthew; Akbare, Shafique; Achart, Jérôme; Kuoch, Sylvain

    2015-03-01

    This study presents an effective engineering approach for human vital signs monitoring as increasingly demanded by personal healthcare. The aim of this work is to study how to capture critical physiological parameters efficiently through a well-constructed electronic system and a robust multi-channel opto-electronic patch sensor (OEPS), together with a wireless communication. A unique design comprising multi-wavelength illumination sources and a rapid response photo sensor with a 3-axis accelerometer enables to recover pulsatile features, compensate motion and increase signal-to-noise ratio. An approved protocol with designated tests was implemented at Loughborough University a UK leader in sport and exercise assessment. The results of sport physiological effects were extracted from the datasets of physical movements, i.e. sitting, standing, waking, running and cycling. t-test, Bland-Altman and correlation analysis were applied to evaluate the performance of the OEPS system against Acti-Graph and Mio-Alpha.There was no difference in heart rate measured using OEPS and both Acti-Graph and Mio-Alpha (both p<0.05). Strong correlations were observed between HR measured from the OEPS and both the Acti-graph and Mio-Alpha (r = 0.96, p<0.001). Bland-Altman analysis for the Acti-Graph and OEPS found the bias 0.85 bpm, the standard deviation 9.20 bpm, and the limits of agreement (LOA) -17.18 bpm to +18.88 bpm for lower and upper limits of agreement respectively, for the Mio-Alpha and OEPS the bias is 1.63 bpm, standard deviation SD8.62 bpm, lower and upper limits of agreement, - 15.27 bpm and +18.58 bpm respectively. The OEPS demonstrates a real time, robust and remote monitoring of cardiovascular function.

  18. Model-Based, Noninvasive Monitoring of Intracranial Pressure

    DTIC Science & Technology

    2013-07-01

    patients. A physiologically based model relates ICP to simultaneously measured waveforms of arterial blood pressure ( ABP ), obtained via radial... ABP and CBFV are currently measured as the clinical standard of care. The project’s major accomplishments include: assembling a suitable system for...synchronized arterial blood pressure ( ABP ) and cerebral blood flow velocity (CBFV) waveform measurements that can be obtained quite routinely. Our processing

  19. Physiologic monitoring. A guide to networking your monitoring systems.

    PubMed

    2011-10-01

    There are many factors to consider when choosing a physiologic monitoring system. not only should these systems perform well clinically, but they should also be able to exchange data with other information systems. We discuss some of the ins and outs of physiologic monitoring system networking and highlight eight product lines from seven suppliers.

  20. Wearable Technology for Chronic Wound Monitoring: Current Dressings, Advancements, and Future Prospects.

    PubMed

    Brown, Matthew S; Ashley, Brandon; Koh, Ahyeon

    2018-01-01

    Chronic non-healing wounds challenge tissue regeneration and impair infection regulation for patients afflicted with this condition. Next generation wound care technology capable of in situ physiological surveillance which can diagnose wound parameters, treat various chronic wound symptoms, and reduce infection at the wound noninvasively with the use of a closed loop therapeutic system would provide patients with an improved standard of care and an accelerated wound repair mechanism. The indicating biomarkers specific to chronic wounds include blood pressure, temperature, oxygen, pH, lactate, glucose, interleukin-6 (IL-6), and infection status. A wound monitoring device would help decrease prolonged hospitalization, multiple doctors' visits, and the expensive lab testing associated with the diagnosis and treatment of chronic wounds. A device capable of monitoring the wound status and stimulating the healing process is highly desirable. In this review, we discuss the impaired physiological states of chronic wounds and explain the current treatment methods. Specifically, we focus on improvements in materials, platforms, fabrication methods for wearable devices, and quantitative analysis of various biomarkers vital to wound healing progress.

  1. Wearable Technology for Chronic Wound Monitoring: Current Dressings, Advancements, and Future Prospects

    PubMed Central

    Brown, Matthew S.; Ashley, Brandon; Koh, Ahyeon

    2018-01-01

    Chronic non-healing wounds challenge tissue regeneration and impair infection regulation for patients afflicted with this condition. Next generation wound care technology capable of in situ physiological surveillance which can diagnose wound parameters, treat various chronic wound symptoms, and reduce infection at the wound noninvasively with the use of a closed loop therapeutic system would provide patients with an improved standard of care and an accelerated wound repair mechanism. The indicating biomarkers specific to chronic wounds include blood pressure, temperature, oxygen, pH, lactate, glucose, interleukin-6 (IL-6), and infection status. A wound monitoring device would help decrease prolonged hospitalization, multiple doctors' visits, and the expensive lab testing associated with the diagnosis and treatment of chronic wounds. A device capable of monitoring the wound status and stimulating the healing process is highly desirable. In this review, we discuss the impaired physiological states of chronic wounds and explain the current treatment methods. Specifically, we focus on improvements in materials, platforms, fabrication methods for wearable devices, and quantitative analysis of various biomarkers vital to wound healing progress. PMID:29755977

  2. The development of a tele-monitoring system for physiological parameters based on the B/S model.

    PubMed

    Shuicai, Wu; Peijie, Jiang; Chunlan, Yang; Haomin, Li; Yanping, Bai

    2010-01-01

    The development of a new physiological multi-parameter remote monitoring system is based on the B/S model. The system consists of a server monitoring center, Internet network and PC-based multi-parameter monitors. Using the B/S model, the clients can browse web pages via the server monitoring center and download and install ActiveX controls. The physiological multi-parameters are collected, displayed and remotely transmitted. The experimental results show that the system is stable, reliable and operates in real time. The system is suitable for use in physiological multi-parameter remote monitoring for family and community healthcare. Copyright © 2010 Elsevier Ltd. All rights reserved.

  3. Continuous Glucose Monitoring (CGM) or Blood Glucose Monitoring (BGM): Interactions and Implications.

    PubMed

    Heinemann, Lutz

    2018-04-01

    At the 2017 10th annual International Conference on Advanced Technologies and Treatments for Diabetes (ATTD) in Paris, France, four speakers presented their perspectives on the roles of continuous glucose monitoring (CGM) and of blood glucose monitoring (BGM) in patient management within one symposium. These presentations included discussions of the differences in the accuracy of CGM and BGM, a clinical perspective on the physiological reasons behind differences in CGM and BGM values, and an overview of the impact of variations in device accuracy on patients with diabetes. Subsequently a short summary of these presentations is given, highlighting the value of good accuracy of BGM or CGM systems and the ongoing need for standardization. The important role of both BGM and CGM in patient management was a theme across all presentations.

  4. Monitoring Physiological Variables with Membrane Probes

    NASA Technical Reports Server (NTRS)

    Janle, Elsa M.

    1997-01-01

    This project has demonstrated the possibility of using membrane probes in rodents to monitor physiological variables for extended periods of time. The utility of these probes in physiological studies of microgravity has been demonstrated. The feasibility of developing on-line sensors has also been demonstrated and allows for the possibility of developing real-time automated monitoring systems which can be used in ground-base physiological research as well as in research and medical monitoring in space. In addition to space applications these techniques can be extended to medical monitoring in critical care situations on earth as well as facilitating research in many human and animal diseases.

  5. Physiologically assessed hot flashes and endothelial function among midlife women.

    PubMed

    Thurston, Rebecca C; Chang, Yuefang; Barinas-Mitchell, Emma; Jennings, J Richard; von Känel, Roland; Landsittel, Doug P; Matthews, Karen A

    2017-08-01

    Hot flashes are experienced by most midlife women. Emerging data indicate that they may be associated with endothelial dysfunction. No studies have tested whether hot flashes are associated with endothelial function using physiologic measures of hot flashes. We tested whether physiologically assessed hot flashes were associated with poorer endothelial function. We also considered whether age modified associations. Two hundred seventy-two nonsmoking women reporting either daily hot flashes or no hot flashes, aged 40 to 60 years, and free of clinical cardiovascular disease, underwent ambulatory physiologic hot flash and diary hot flash monitoring; a blood draw; and ultrasound measurement of brachial artery flow-mediated dilation to assess endothelial function. Associations between hot flashes and flow-mediated dilation were tested in linear regression models controlling for lumen diameter, demographics, cardiovascular disease risk factors, and estradiol. In multivariable models incorporating cardiovascular disease risk factors, significant interactions by age (P < 0.05) indicated that among the younger tertile of women in the sample (age 40-53 years), the presence of hot flashes (beta [standard error] = -2.07 [0.79], P = 0.01), and more frequent physiologic hot flashes (for each hot flash: beta [standard error] = -0.10 [0.05], P = 0.03, multivariable) were associated with lower flow-mediated dilation. Associations were not accounted for by estradiol. Associations were not observed among the older women (age 54-60 years) or for self-reported hot flash frequency, severity, or bother. Among the younger women, hot flashes explained more variance in flow-mediated dilation than standard cardiovascular disease risk factors or estradiol. Among younger midlife women, frequent hot flashes were associated with poorer endothelial function and may provide information about women's vascular status beyond cardiovascular disease risk factors and estradiol.

  6. Evaluative priming reveals dissociable effects of cognitive versus physiological anxiety on action monitoring.

    PubMed

    De Saedeleer, Lien; Pourtois, Gilles

    2016-06-01

    Performance monitoring enables the rapid detection of mismatches between goals or intentions and actions, as well as subsequent behavioral adjustment by means of enhanced attention control. These processes are not encapsulated, but they are readily influenced by affective or motivational variables, including negative affect. Here we tested the prediction that worry, the cognitive component of anxiety, and arousal, its physiological counterpart, can each influence specific processes during performance monitoring. In 2 experiments, participants were asked to discriminate the valence of emotional words that were preceded by either correct (good) or incorrect (bad) actions, serving as primes in a standard evaluative priming procedure. In Experiment 1 (n = 36) we examined the influence of trait worry and arousal. Additionally, we included a face priming task to examine the specificity of this effect. Stepwise linear regression analyses showed that increased worry, but not arousal, weakened the evaluative priming effect and therefore the rapid and automatic processing of actions as good or bad. By contrast, arousal, but not worry, increased posterror slowing. In Experiment 2 (n = 30) state worry was induced using an anagram task. Effects of worry on action monitoring were trait but not state dependent, and only evidenced when actions were directly used as primes. These results suggest a double dissociation between worry and arousal during performance monitoring. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  7. Covert video monitoring in the assessment of medically unexplained symptoms in children.

    PubMed

    Wallace, Dustin P; Sim, Leslie A; Harrison, Tracy E; Bruce, Barbara K; Harbeck-Weber, Cynthia

    2012-04-01

    Diagnosis of medically unexplained symptoms (MUS) occurs after thorough evaluations have failed to identify a physiological cause for symptoms. However, families and providers may wonder if something has been missed, leading to reduced confidence in behavioral treatment. Confidence may be improved through the use of technology such as covert video monitoring to better assess functioning across settings. A 12-year-old male presented with progressive neurological decline, precipitated by chronic pain. After thorough evaluation and the failure of standard treatments (medical, rehabilitative, and psychological) covert video monitoring revealed that the patient demonstrated greater abilities when alone in his room. Negative reinforcement was used to initiate recovery, accompanied by positive reinforcement and a rehabilitative approach. Covert video monitoring assisted in three subsequent cases over the following 3 years. In certain complex cases, video monitoring can inform the assessment and treatment of MUS. Discussion includes ethical and practical considerations.

  8. Effects of daily kangaroo care on cardiorespiratory parameters in preterm infants.

    PubMed

    Mitchell, A J; Yates, C; Williams, K; Hall, R W

    2013-01-01

    Kangaroo care (KC) has possible benefits for promoting physiological stability and positive developmental outcomes in preterm infants. The purpose of this study was to compare bradycardia and oxygen desaturation events in preterm infants in standard incubator care versus KC. Thirty-eight infants 27 to 30 weeks gestational age were randomly assigned to 2 hours of KC daily between days of life 5 to 10 or to standard incubator care. Infants were monitored for bradycardia (heart rate <80) or oxygen desaturation (<80%). Analysis of hourly events was based on three sets of data: standard care group 24 hours daily, KC group during incubator time 22 hours daily, and KC group during holding time 2 hours daily. The KC group had fewer bradycardia events per hour while being held compared to time spent in an incubator (p = 0.048). The KC group also had significantly fewer oxygen desaturation events while being held than while in the incubator (p = 0.017) and significantly fewer desaturation events than infants in standard care (p = 0.02). KC reduces bradycardia and oxygen desaturation events in preterm infants, providing physiological stability and possible benefits for neurodevelopmental outcomes.

  9. [In life determination of the physiological status of decapod crustaceans (Crustacea: Decapoda) by hematological characteristics].

    PubMed

    Aleksandrova, E N; Kovacheva, N P

    2010-01-01

    The application of hematological analysis techniques to detecting the physiological status of the economically valued decapods during their culturing, and in monitoring of the condition of their natural populations, is restrained by the incomplete knowledge of these invertebrates circulatory system and its properties. Scarce data on the use of hematological indicators for determining the physiological status of decapods may be found sporadically in published sources; there is shortage of basic standards needed for interpretation of the analytical results. In this regard the paper considers some data on the major properties of hemolymph and its cellular elements; on methods of their examination; and on the results of application of hematological characteristics to assessing the physiological condition of various species of decapods. The hematological indicators suitable for the analysis of live decapods include: time of coagulation and buffer characteristic of hemolymph; concentration of total proteins, copper, calcium, glucose and lactates in it; total number of hemocytes with the consideration of granulocytes share.

  10. The benefits of integrating Internet technology with standard communications for telemedicine in extreme environments.

    PubMed

    Harnett, B M; Satava, R; Angood, P; Merriam, N R; Doarn, C R; Merrell, R C

    2001-12-01

    The ability to continuously monitor the vital signs of a person can be beneficial especially if the environment is hazardous or a person simply has general health concerns. We wanted to ascertain if, by integrating the Internet, ubiquitous switching technologies and off-the-shelf tools, this "suite of services" could provide a topology to enable remote monitoring in extreme and remote locations. An evaluation of this approach was conducted at the base camp of Mount Everest in the spring of 1999. Three climbers were outfitted with wireless, wearable sensors and transmitters for 24 h as they ascended through the Khumbu Icefall toward Camp One. The physiologic data was forwarded to the receiving station at Base Camp where it was forwarded to the U.S. mainland. Two of the three devices delivered physiologic data 95%-100% of the time while the third unit operated at only 78%. According to the climbers, the devices were unobtrusive, however, any additional weight while climbing Everest must provide advantage.

  11. Thermal-work strain in law enforcement personnel during chemical, biological, radiological, and nuclear (CBRN) training

    PubMed Central

    Yokota, M; Karis, A J; Tharion, W J

    2014-01-01

    Background: Thermal safety standards for the use of chemical, biological, radiological, and nuclear (CBRN) ensembles have been established for various US occupations, but not for law enforcement personnel. Objectives: We examined thermal strain levels of 30 male US law enforcement personnel who participated in CBRN field training in Arizona, Florida, and Massachusetts. Methods: Physiological responses were examined using unobtrusive heart rate (HR) monitors and a simple thermoregulatory model to predict core temperature (Tc) using HR and environment. Results: Thermal strain levels varied by environments, activity levels, and type of CBRN ensemble. Arizona and Florida volunteers working in hot-dry and hot-humid environment indicated high heat strain (predicted max Tc>38.5°C). The cool environment of Massachusetts reduced thermal strain although thermal strains were occasionally moderate. Conclusions: The non-invasive method of using physiological monitoring and thermoregulatory modeling could improve law enforcement mission to reduce the risk of heat illness or injury. PMID:24999847

  12. Pre-performance Physiological State: Heart Rate Variability as a Predictor of Shooting Performance.

    PubMed

    Ortega, E; Wang, C J K

    2018-03-01

    Heart rate variability (HRV) is commonly used in sport science for monitoring the physiology of athletes but not as an indicator of physiological state from a psychological perspective. Since HRV is established to be an indicator of emotional responding, it could be an objective means of quantifying an athlete's subjective physiological state before competition. A total of 61 sport shooters participated in this study, of which 21 were novice shooters, 19 were intermediate shooters, and 21 were advanced level shooters. HRV, self-efficacy, and use of mental skills were assessed before they completed a standard shooting performance task of 40 shots, as in a competition qualifying round. The results showed that HRV was significantly positively correlated with self-efficacy and performance and was a significant predictor of shooting performance. In addition, advanced shooters were found to have significantly lower average heart rate before shooting and used more self-talk, relaxation, imagery, and automaticity compared to novice and intermediate shooters. HRV was found to be useful in identifying the physiological state of an athlete before competing, and as such, coaches and athletes can adopt practical strategies to improve the pre-performance physiological state as a means to optimize performance.

  13. EFFECTIVE INDICES FOR MONITORING MENTAL WORKLOAD WHILE PERFORMING MULTIPLE TASKS.

    PubMed

    Hsu, Bin-Wei; Wang, Mao-Jiun J; Chen, Chi-Yuan; Chen, Fang

    2015-08-01

    This study identified several physiological indices that can accurately monitor mental workload while participants performed multiple tasks with the strategy of maintaining stable performance and maximizing accuracy. Thirty male participants completed three 10-min. simulated multitasks: MATB (Multi-Attribute Task Battery) with three workload levels. Twenty-five commonly used mental workload measures were collected, including heart rate, 12 HRV (heart rate variability), 10 EEG (electroencephalography) indices (α, β, θ, α/θ, θ/β from O1-O2 and F4-C4), and two subjective measures. Analyses of index sensitivity showed that two EEG indices, θ and α/θ (F4-C4), one time-domain HRV-SDNN (standard deviation of inter-beat intervals), and four frequency-domain HRV: VLF (very low frequency), LF (low frequency), %HF (percentage of high frequency), and LF/HF were sensitive to differentiate high workload. EEG α/θ (F4-C4) and LF/HF were most effective for monitoring high mental workload. LF/HF showed the highest correlations with other physiological indices. EEG α/θ (F4-C4) showed strong correlations with subjective measures across different mental workload levels. Operation strategy would affect the sensitivity of EEG α (F4-C4) and HF.

  14. Challenges of physiological monitoring in a Navy operational setting

    NASA Technical Reports Server (NTRS)

    Banta, Guy R.

    1988-01-01

    Challenges to physiological monitoring in the Navy include environmental extremes, acceptance of use by test subjects, data transfer, data interpretation, and capability of relating collected data to valid operational relevant criterion measures. These problems are discussed with respect to diving, electrophysiological monitoring, in-flight monitoring, aircrew fatigue, in-flight cardiac stress, and in-flight monitoring devices.

  15. A wearable physiological sensor suite for unobtrusive monitoring of physiological and cognitive state.

    PubMed

    Matthews, Robert; McDonald, Neil J; Hervieux, Paul; Turner, Peter J; Steindorf, Martin A

    2007-01-01

    This paper describes an integrated Physiological Sensor Suite (PSS) based upon QUASAR's innovative non-invasive bioelectric sensor technologies that will provide, for the first time, a fully integrated, noninvasive methodology for physiological sensing. The PSS currently under development at QUASAR is a state-of-the-art multimodal array of sensors that, along with an ultra-low power personal area wireless network, form a comprehensive body-worn system for real-time monitoring of subject physiology and cognitive status. Applications of the PSS extend from monitoring of military personnel to long-term monitoring of patients diagnosed with cardiac or neurological conditions. Results for side-by-side comparisons between QUASAR's biosensor technology and conventional wet electrodes are presented. The signal fidelity for bioelectric measurements using QUASAR's biosensors is comparable to that for wet electrodes.

  16. Optoacoustic Monitoring of Physiologic Variables

    PubMed Central

    Esenaliev, Rinat O.

    2017-01-01

    Optoacoustic (photoacoustic) technique is a novel diagnostic platform that can be used for noninvasive measurements of physiologic variables, functional imaging, and hemodynamic monitoring. This technique is based on generation and time-resolved detection of optoacoustic (thermoelastic) waves generated in tissue by short optical pulses. This provides probing of tissues and individual blood vessels with high optical contrast and ultrasound spatial resolution. Because the optoacoustic waves carry information on tissue optical and thermophysical properties, detection, and analysis of the optoacoustic waves allow for measurements of physiologic variables with high accuracy and specificity. We proposed to use the optoacoustic technique for monitoring of a number of important physiologic variables including temperature, thermal coagulation, freezing, concentration of molecular dyes, nanoparticles, oxygenation, and hemoglobin concentration. In this review we present origin of contrast and high spatial resolution in these measurements performed with optoacoustic systems developed and built by our group. We summarize data obtained in vitro, in experimental animals, and in humans on monitoring of these physiologic variables. Our data indicate that the optoacoustic technology may be used for monitoring of cerebral blood oxygenation in patients with traumatic brain injury and in neonatal patients, central venous oxygenation monitoring, total hemoglobin concentration monitoring, hematoma detection and characterization, monitoring of temperature, and coagulation and freezing boundaries during thermotherapy. PMID:29311964

  17. Optoacoustic Monitoring of Physiologic Variables.

    PubMed

    Esenaliev, Rinat O

    2017-01-01

    Optoacoustic (photoacoustic) technique is a novel diagnostic platform that can be used for noninvasive measurements of physiologic variables, functional imaging, and hemodynamic monitoring. This technique is based on generation and time-resolved detection of optoacoustic (thermoelastic) waves generated in tissue by short optical pulses. This provides probing of tissues and individual blood vessels with high optical contrast and ultrasound spatial resolution. Because the optoacoustic waves carry information on tissue optical and thermophysical properties, detection, and analysis of the optoacoustic waves allow for measurements of physiologic variables with high accuracy and specificity. We proposed to use the optoacoustic technique for monitoring of a number of important physiologic variables including temperature, thermal coagulation, freezing, concentration of molecular dyes, nanoparticles, oxygenation, and hemoglobin concentration. In this review we present origin of contrast and high spatial resolution in these measurements performed with optoacoustic systems developed and built by our group. We summarize data obtained in vitro , in experimental animals, and in humans on monitoring of these physiologic variables. Our data indicate that the optoacoustic technology may be used for monitoring of cerebral blood oxygenation in patients with traumatic brain injury and in neonatal patients, central venous oxygenation monitoring, total hemoglobin concentration monitoring, hematoma detection and characterization, monitoring of temperature, and coagulation and freezing boundaries during thermotherapy.

  18. Implementation of body area networks based on MICS/WMTS medical bands for healthcare systems.

    PubMed

    Yuce, Mehmet R; Ho, Chee Keong

    2008-01-01

    A multi-hoping sensor network system has been implemented to monitor physiological parameters from multiple patient bodies by means of medical communication standards MICS (Medical Implant Communication Service) and WMTS (Wireless Medical Telemetry Service). Unlike the other medical sensor networks (they usually use 2.4 GHz ISM band), we used the two medical standards occupying the frequency bands that are mainly assigned to medical applications. The prototype system uses the MICS band (402-405 MHz) between the sensor nodes and a remote central control unit (CCU). And WMTS frequencies (608-614MHz) are used between the CCUs and the remote base stations allowing for a much larger range acting as an intermediate node. The sensor nodes in the prototype can measure up to four body signals (i.e. 4-channel) where one is dedicated to a continuous physiological signal such as ECC/EEG. The system includes firmware and software designs that can provide a long distance data transfer through the internet or a mobile network.

  19. Evaluating the health of compromised tissues using a near-infrared spectroscopic imaging system in clinical settings: lessons learned

    NASA Astrophysics Data System (ADS)

    Leonardi, Lorenzo; Sowa, Michael G.; Hewko, Mark D.; Schattka, Bernhard J.; Payette, Jeri R.; Hastings, Michelle; Posthumus, Trevor B.; Mantsch, Henry H.

    2003-07-01

    The present and accepted standard for determining the status of tissue relies on visual inspection of the tissue. Based on the surface appearance of the tissue, medical personnel will make an assessment of the tissue and proceed to a course of action or treatment. Visual inspection of tissue is central to many areas of clinical medicine, and remains a cornerstone of dermatology, reconstructive plastic surgery, and in the management of chronic wounds, and burn injuries. Near infrared spectroscopic imaging holds the promise of being able to monitor the dynamics of tissue physiology in real-time and detect pathology in living tissue. The continuous measurement of metabolic, physiological, or structural changes in tissue is of primary concern in many clinical and biomedical domains. A near infrared hyperspectral imaging system was constructed for the assessment of burn injuries and skin flaps or skin grafts. This device merged basic science with engineering and integrated manufacturing to develop a device suitable to detect ischemic tissue. This device has the potential of providing measures of tissue physiology, oxygen delivery and tissue hydration during patient screening, in the operating room or during therapy and post-operative/treatment monitoring. Results from a pre-clinical burn injury study will be presented.

  20. A Wireless Emergency Telemedicine System for Patients Monitoring and Diagnosis

    PubMed Central

    Abo-Zahhad, M.; Ahmed, Sabah M.; Elnahas, O.

    2014-01-01

    Recently, remote healthcare systems have received increasing attention in the last decade, explaining why intelligent systems with physiology signal monitoring for e-health care are an emerging area of development. Therefore, this study adopts a system which includes continuous collection and evaluation of multiple vital signs, long-term healthcare, and a cellular connection to a medical center in emergency case and it transfers all acquired raw data by the internet in normal case. The proposed system can continuously acquire four different physiological signs, for example, ECG, SpO2, temperature, and blood pressure and further relayed them to an intelligent data analysis scheme to diagnose abnormal pulses for exploring potential chronic diseases. The proposed system also has a friendly web-based interface for medical staff to observe immediate pulse signals for remote treatment. Once abnormal event happened or the request to real-time display vital signs is confirmed, all physiological signs will be immediately transmitted to remote medical server through both cellular networks and internet. Also data can be transmitted to a family member's mobile phone or doctor's phone through GPRS. A prototype of such system has been successfully developed and implemented, which will offer high standard of healthcare with a major reduction in cost for our society. PMID:24883059

  1. Application of step-frequency radars in medicine

    NASA Astrophysics Data System (ADS)

    Anishchenko, L.; Alekhin, M.; Tataraidze, A.; Ivashov, S.; Bugaev, Alexander S.; Soldovieri, F.

    2014-05-01

    The paper summarizes results of step-frequency radars application in medicine. Remote and non-contact control of physiological parameters with modern bioradars provides a wide range of possibilities for non-contact remote monitoring of a human psycho-emotional state and physiological condition. The paper provides information about technical characteristics of bioradars designed at Bauman Moscow State Technical University and experiments using them. Results of verification experiment showed that bioradars of BioRASCAN type may be used for simultaneous remote measurements of breathing and heart rate parameters. In addition, bioradar assisted experiments for detecting of different sleep disorders are described. Their results proved that method of bioradiolocation allows correct estimation of obstructive sleep apnea severity compared to the polysomnography method, which satisfies standard medical recommendations.

  2. A multi-channel opto-electronic sensor to accurately monitor heart rate against motion artefact during exercise.

    PubMed

    Alzahrani, Abdullah; Hu, Sijung; Azorin-Peris, Vicente; Barrett, Laura; Esliger, Dale; Hayes, Matthew; Akbare, Shafique; Achart, Jérôme; Kuoch, Sylvain

    2015-10-12

    This study presents the use of a multi-channel opto-electronic sensor (OEPS) to effectively monitor critical physiological parameters whilst preventing motion artefact as increasingly demanded by personal healthcare. The aim of this work was to study how to capture the heart rate (HR) efficiently through a well-constructed OEPS and a 3-axis accelerometer with wireless communication. A protocol was designed to incorporate sitting, standing, walking, running and cycling. The datasets collected from these activities were processed to elaborate sport physiological effects. t-test, Bland-Altman Agreement (BAA), and correlation to evaluate the performance of the OEPS were used against Polar and Mio-Alpha HR monitors. No differences in the HR were found between OEPS, and either Polar or Mio-Alpha (both p > 0.05); a strong correlation was found between Polar and OEPS (r: 0.96, p < 0.001); the bias of BAA 0.85 bpm, the standard deviation (SD) 9.20 bpm, and the limits of agreement (LOA) from -17.18 bpm to +18.88 bpm. For the Mio-Alpha and OEPS, a strong correlation was found (r: 0.96, p < 0.001); the bias of BAA 1.63 bpm, SD 8.62 bpm, LOA from -15.27 bpm to +18.58 bpm. These results demonstrate the OEPS to be capable of carrying out real time and remote monitoring of heart rate.

  3. A Waveform Archiving System for the GE Solar 8000i Bedside Monitor.

    PubMed

    Fanelli, Andrea; Jaishankar, Rohan; Filippidis, Aristotelis; Holsapple, James; Heldt, Thomas

    2018-01-01

    Our objective was to develop, deploy, and test a data-acquisition system for the reliable and robust archiving of high-resolution physiological waveform data from a variety of bedside monitoring devices, including the GE Solar 8000i patient monitor, and for the logging of ancillary clinical and demographic information. The data-acquisition system consists of a computer-based archiving unit and a GE Tram Rac 4A that connects to the GE Solar 8000i monitor. Standard physiological front-end sensors connect directly to the Tram Rac, which serves as a port replicator for the GE monitor and provides access to these waveform signals through an analog data interface. Together with the GE monitoring data streams, we simultaneously collect the cerebral blood flow velocity envelope from a transcranial Doppler ultrasound system and a non-invasive arterial blood pressure waveform along a common time axis. All waveform signals are digitized and archived through a LabView-controlled interface that also allows for the logging of relevant meta-data such as clinical and patient demographic information. The acquisition system was certified for hospital use by the clinical engineering team at Boston Medical Center, Boston, MA, USA. Over a 12-month period, we collected 57 datasets from 11 neuro-ICU patients. The system provided reliable and failure-free waveform archiving. We measured an average temporal drift between waveforms from different monitoring devices of 1 ms every 66 min of recorded data. The waveform acquisition system allows for robust real-time data acquisition, processing, and archiving of waveforms. The temporal drift between waveforms archived from different devices is entirely negligible, even for long-term recording.

  4. Automated acquisition system for routine, noninvasive monitoring of physiological data.

    PubMed

    Ogawa, M; Tamura, T; Togawa, T

    1998-01-01

    A fully automated, noninvasive data-acquisition system was developed to permit long-term measurement of physiological functions at home, without disturbing subjects' normal routines. The system consists of unconstrained monitors built into furnishings and structures in a home environment. An electrocardiographic (ECG) monitor in the bathtub measures heart function during bathing, a temperature monitor in the bed measures body temperature, and a weight monitor built into the toilet serves as a scale to record weight. All three monitors are connected to one computer and function with data-acquisition programs and a data format rule. The unconstrained physiological parameter monitors and fully automated measurement procedures collect data noninvasively without the subject's awareness. The system was tested for 1 week by a healthy male subject, aged 28, in laboratory-based facilities.

  5. Pulse oximeter for cyclists in smartphone

    NASA Astrophysics Data System (ADS)

    Martins, L.; Gaidos, O.; dos Santos, I.

    2015-01-01

    The monitoring of cyclists during physical activity is an important factor to improve their performance. We discuss a new approaches based on smartphone for monitoring physiological signal wirelessly for cyclists, using a pulse oximeter sensor attached to the rider's forehead. This paper presents a wireless pulse Oximeter that was developed with a Nellcor's module, which uses the Standard Host Interface Protocol (SHIP) for communication with the Bluetooth module and sends data for a Smartphone with Android O.S. Then these data are shown in the screen: the heartbeat and saturation percentage. The application was created with App Inventor and the data are sent to Google Maps via Twitter. The results demonstrate the possibility of developing a successful prototype.

  6. Intensive care window: real-time monitoring and analysis in the intensive care environment.

    PubMed

    Stylianides, Nikolas; Dikaiakos, Marios D; Gjermundrød, Harald; Panayi, George; Kyprianou, Theodoros

    2011-01-01

    This paper introduces a novel, open-source middleware framework for communication with medical devices and an application using the middleware named intensive care window (ICW). The middleware enables communication with intensive care unit bedside-installed medical devices over standard and proprietary communication protocol stacks. The ICW application facilitates the acquisition of vital signs and physiological parameters exported from patient-attached medical devices and sensors. Moreover, ICW provides runtime and post-analysis procedures for data annotation, data visualization, data query, and analysis. The ICW application can be deployed as a stand-alone solution or in conjunction with existing clinical information systems providing a holistic solution to inpatient medical condition monitoring, early diagnosis, and prognosis.

  7. Role of Large Clinical Datasets From Physiologic Monitors in Improving the Safety of Clinical Alarm Systems and Methodological Considerations: A Case From Philips Monitors.

    PubMed

    Sowan, Azizeh Khaled; Reed, Charles Calhoun; Staggers, Nancy

    2016-09-30

    Large datasets of the audit log of modern physiologic monitoring devices have rarely been used for predictive modeling, capturing unsafe practices, or guiding initiatives on alarm systems safety. This paper (1) describes a large clinical dataset using the audit log of the physiologic monitors, (2) discusses benefits and challenges of using the audit log in identifying the most important alarm signals and improving the safety of clinical alarm systems, and (3) provides suggestions for presenting alarm data and improving the audit log of the physiologic monitors. At a 20-bed transplant cardiac intensive care unit, alarm data recorded via the audit log of bedside monitors were retrieved from the server of the central station monitor. Benefits of the audit log are many. They include easily retrievable data at no cost, complete alarm records, easy capture of inconsistent and unsafe practices, and easy identification of bedside monitors missed from a unit change of alarm settings adjustments. Challenges in analyzing the audit log are related to the time-consuming processes of data cleaning and analysis, and limited storage and retrieval capabilities of the monitors. The audit log is a function of current capabilities of the physiologic monitoring systems, monitor's configuration, and alarm management practices by clinicians. Despite current challenges in data retrieval and analysis, large digitalized clinical datasets hold great promise in performance, safety, and quality improvement. Vendors, clinicians, researchers, and professional organizations should work closely to identify the most useful format and type of clinical data to expand medical devices' log capacity.

  8. A synthetic multifunctional mammalian pH sensor and CO2 transgene-control device.

    PubMed

    Ausländer, David; Ausländer, Simon; Charpin-El Hamri, Ghislaine; Sedlmayer, Ferdinand; Müller, Marius; Frey, Olivier; Hierlemann, Andreas; Stelling, Jörg; Fussenegger, Martin

    2014-08-07

    All metabolic activities operate within a narrow pH range that is controlled by the CO2-bicarbonate buffering system. We hypothesized that pH could serve as surrogate signal to monitor and respond to the physiological state. By functionally rewiring the human proton-activated cell-surface receptor TDAG8 to chimeric promoters, we created a synthetic signaling cascade that precisely monitors extracellular pH within the physiological range. The synthetic pH sensor could be adjusted by organic acids as well as gaseous CO2 that shifts the CO2-bicarbonate balance toward hydrogen ions. This enabled the design of gas-programmable logic gates, provided remote control of cellular behavior inside microfluidic devices, and allowed for CO2-triggered production of biopharmaceuticals in standard bioreactors. When implanting cells containing the synthetic pH sensor linked to production of insulin into type 1 diabetic mice developing diabetic ketoacidosis, the prosthetic network automatically scored acidic pH and coordinated an insulin expression response that corrected ketoacidosis. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Evaluation of wet bulb globe temperature index for estimation of heat strain in hot/humid conditions in the Persian Gulf.

    PubMed

    Dehghan, Habibolah; Mortazavi, Seyed Bagher; Jafari, Mohammad J; Maracy, Mohammad R

    2012-12-01

    Heat exposure among construction workers in the Persian Gulf region is a serious hazard for health. The aim of this study was to evaluate the performance of wet bulb globe temperature (WBGT) Index for estimation of heat strain in hot/humid conditions by the use of Physiological Strain Index (PSI) as the gold standard. This cross-sectional study was carried out on 71 workers of two Petrochemical Companies in South of Iran in 2010 summer. The WBGT index, heart rate, and aural temperature were measured by Heat Stress Monitor (Casella Microtherm WBGT), Heart Rate Monitor (Polar RS100), and Personal Heat Strain Monitor (Questemp II), respectively. The obtained data were analyzed with descriptive statistics and Pearson correlation analysis. The mean (SD) of WBGT values was 33.1 (2.7). The WBGT values exceed from American Conference of Governmental Industrial Hygienists (ACGIH) standard (30°C) in 96% work stations, whereas the PSI values were more than 5.0 (moderate strain) in 11% of workstations. The correlation between WBGT and PSI values was 0.61 (P = 0.001). When WBGT values were less and more than 34°C, the mean of PSI was 2.6 (low strain) and 5.2 (moderate strain), respectively. In the Persian Gulf weather, especially hot and humid in the summer months, due to the WBGT values exceeding 30°C (in 96% of cases) and weak correlation between WBGT and PSI, the work/rest cycles of WBGT Index is not suitable for heat stress management. Therefore, in Persian Gulf weather, heat stress evaluation based on physiologic variables may have higher validity than WBGT index.

  10. Evaluation of wet bulb globe temperature index for estimation of heat strain in hot/humid conditions in the Persian Gulf

    PubMed Central

    Dehghan, Habibolah; Mortazavi, Seyed Bagher; Jafari, Mohammad J.; Maracy, Mohammad R.

    2012-01-01

    Background: Heat exposure among construction workers in the Persian Gulf region is a serious hazard for health. The aim of this study was to evaluate the performance of wet bulb globe temperature (WBGT) Index for estimation of heat strain in hot/humid conditions by the use of Physiological Strain Index (PSI) as the gold standard. Material and Methods: This cross-sectional study was carried out on 71 workers of two Petrochemical Companies in South of Iran in 2010 summer. The WBGT index, heart rate, and aural temperature were measured by Heat Stress Monitor (Casella Microtherm WBGT), Heart Rate Monitor (Polar RS100), and Personal Heat Strain Monitor (Questemp II), respectively. The obtained data were analyzed with descriptive statistics and Pearson correlation analysis. Results: The mean (SD) of WBGT values was 33.1 (2.7). The WBGT values exceed from American Conference of Governmental Industrial Hygienists (ACGIH) standard (30°C) in 96% work stations, whereas the PSI values were more than 5.0 (moderate strain) in 11% of workstations. The correlation between WBGT and PSI values was 0.61 (P = 0.001). When WBGT values were less and more than 34°C, the mean of PSI was 2.6 (low strain) and 5.2 (moderate strain), respectively. Conclusion: In the Persian Gulf weather, especially hot and humid in the summer months, due to the WBGT values exceeding 30°C (in 96% of cases) and weak correlation between WBGT and PSI, the work/rest cycles of WBGT Index is not suitable for heat stress management. Therefore, in Persian Gulf weather, heat stress evaluation based on physiologic variables may have higher validity than WBGT index. PMID:23853626

  11. Multifactorial monitoring of training load in elite rugby sevens players: cortisol/cortisone ratio as a valid tool of training load monitoring

    PubMed Central

    Bouaziz, T; Makni, E; Passelergue, P; Tabka, Z; Lac, G; Moalla, W; Chamari, K

    2016-01-01

    The effectiveness of selected physiological and perceptual measures for monitoring training load and fatigue was studied in 16 male elite rugby sevens players during a 6-week intense training block (IT) and 2-week tapering (TAP). Daily training load (TL) and strain (TS) as well as weekly total score of fatigue (TSF) were quantified respectively by the session-rating of perceived exertion (RPE) method and an 8-item questionnaire. Also, testing was performed and 24 h urinary cortisol (C), cortisone (Cn), adrenaline (A) and noradrenalin (NA) excretion was measured before (T0) and after the IT (T1) and after the TAP (T2). The TL, TS and TSF increased during the IT and decreased during the TAP, in conjunction with a significant drop and improvement, respectively, of performance standards during the two periods. At T1, C and Cn levels increased while A and NA levels decreased, resulting in a higher C/Cn ratio and lower A/NA ratio, respectively. At T2, both C/Cn and A/NA returned to baseline values. The changes in C/Cn ratio, after the 6-week IT, were more closely related to mean TL, TS and TSF (r=0.75-0.76 vs. r=0.48-0.58, p<0.01) and to changes in the majority of performance measures than to A/NA ratio. Only the changes in C/Cn ratio after the 2-week TAP were related to mean TL, TS and TSF (r=0.61-0.68, p<0.01). The changes in hormone levels, training strain and performance standards reflected the physical and mental stressors of training, with complete recovery, as indicated by physiological homeostasis, achieved after an appropriate tapering period. PMID:27601777

  12. An Internet of Things based physiological signal monitoring and receiving system for virtual enhanced health care network.

    PubMed

    Rajan, J Pandia; Rajan, S Edward

    2018-01-01

    Wireless physiological signal monitoring system designing with secured data communication in the health care system is an important and dynamic process. We propose a signal monitoring system using NI myRIO connected with the wireless body sensor network through multi-channel signal acquisition method. Based on the server side validation of the signal, the data connected to the local server is updated in the cloud. The Internet of Things (IoT) architecture is used to get the mobility and fast access of patient data to healthcare service providers. This research work proposes a novel architecture for wireless physiological signal monitoring system using ubiquitous healthcare services by virtual Internet of Things. We showed an improvement in method of access and real time dynamic monitoring of physiological signal of this remote monitoring system using virtual Internet of thing approach. This remote monitoring and access system is evaluated in conventional value. This proposed system is envisioned to modern smart health care system by high utility and user friendly in clinical applications. We claim that the proposed scheme significantly improves the accuracy of the remote monitoring system compared to the other wireless communication methods in clinical system.

  13. Wearable dry sensors with bluetooth connection for use in remote patient monitoring systems.

    PubMed

    Gargiulo, Gaetano; Bifulco, Paolo; Cesarelli, Mario; Jin, Craig; McEwan, Alistair; van Schaik, Andre

    2010-01-01

    Cost reduction has become the primary theme of healthcare reforms globally. More providers are moving towards remote patient monitoring, which reduces the length of hospital stays and frees up their physicians and nurses for acute cases and helps them to tackle staff shortages. Physiological sensors are commonly used in many human specialties e.g. electrocardiogram (ECG) electrodes, for monitoring heart signals, and electroencephalogram (EEG) electrodes, for sensing the electrical activity of the brain, are the most well-known applications. Consequently there is a substantial unmet need for physiological sensors that can be simply and easily applied by the patient or primary carer, are comfortable to wear, can accurately sense parameters over long periods of time and can be connected to data recording systems using Bluetooth technology. We have developed a small, battery powered, user customizable portable monitor. This prototype is capable of recording three-axial body acceleration, skin temperature, and has up to four bio analogical front ends. Moreover, it is also able of continuous wireless transmission to any Bluetooth device including a PDA or a cellular phone. The bio-front end can use long-lasting dry electrodes or novel textile electrodes that can be embedded in clothes. The device can be powered by a standard mobile phone which has a Ni-MH 3.6 V battery, to sustain more than seven days continuous functioning when using the Bluetooth Sniff mode to reduce TX power. In this paper, we present some of the evaluation experiments of our wearable personal monitor device with a focus on ECG applications.

  14. Mobile real-time data acquisition system for application in preventive medicine.

    PubMed

    Neubert, Sebastian; Arndt, Dagmar; Thurow, Kerstin; Stoll, Regina

    2010-05-01

    In this article, the development of a system for online monitoring of a subject's physiological parameters and subjective workload regardless of location has been presented, which allows for studies on occupational health. In the sector of occupational health, modern acquisition systems are needed. Such systems can be used by the subject during usual daily routines without being influenced by the presence of an examiner. Moreover, the system's influence on the subject should be reduced to a minimum to receive reliable data from the examination. The acquisition system is based on a mobile handheld (or smart phone), which allows both management of the communication process and input of several dialog data (e.g., questionnaires). A sensor electronics module permits the acquisition of different physiological parameters and their online transmission to the handheld via Bluetooth. The mobile handheld and the sensor electronics module constitute a wireless personal area network. The handheld allows the first analysis, the synchronization of the data, and the continuous data transfer to a communication server by the integrated mobile radio standards of the handheld. The communication server stores the incoming data of several subjects in an application-dependent database and allows access from all over the world via a Web-based management system. The developed system permits one examiner to monitor the physiological parameters and the subjective workload of several subjects in different locations at the same time. Thereby the subjects can move almost freely in any area covered by the mobile network. The mobile handheld allows the popping-up of the questionnaires at flexible time intervals. This electronic input of the dialog data, in comparison to the manual documentation on papers, is more comfortable to the subject as well as to the examiner for an analysis. A Web-based management application facilitates a continuous remote monitoring of the physiological and the subjective data of the subject.

  15. Amino acid analysis in physiological samples by GC-MS with propyl chloroformate derivatization and iTRAQ-LC-MS/MS.

    PubMed

    Dettmer, Katja; Stevens, Axel P; Fagerer, Stephan R; Kaspar, Hannelore; Oefner, Peter J

    2012-01-01

    Two mass spectrometry-based methods for the quantitative analysis of free amino acids are described. The first method uses propyl chloroformate/propanol derivatization and gas chromatography-quadrupole mass spectrometry (GC-qMS) analysis in single-ion monitoring mode. Derivatization is carried out directly in aqueous samples, thereby allowing automation of the entire procedure, including addition of reagents, extraction, and injection into the GC-MS. The method delivers the quantification of 26 amino acids. The isobaric tagging for relative and absolute quantification (iTRAQ) method employs the labeling of amino acids with isobaric iTRAQ tags. The tags contain two different cleavable reporter ions, one for the sample and one for the standard, which are detected by fragmentation in a tandem mass spectrometer. Reversed-phase liquid chromatography of the labeled amino acids is performed prior to mass spectrometric analysis to separate isobaric amino acids. The commercial iTRAQ kit allows for the analysis of 42 physiological amino acids with a respective isotope-labeled standard for each of these 42 amino acids.

  16. Prediction of HR/BP response to the spontaneous breathing trial by fluctuation dissipation theory

    NASA Astrophysics Data System (ADS)

    Chen, Man

    2014-03-01

    We applied the non-equilibrium fluctuation dissipation theorem to predict how critically-ill patients respond to treatment, based on both heart rate data and blood pressure data collected by standard hospital monitoring devices. The non-equilibrium fluctuation dissipation theorem relates the response of a system to a perturbation to the fluctuations in the stationary state of the system. It is shown that the response of patients to a standard procedure performed on patients, the spontaneous breathing trial (SBT), can be predicted by the non-equilibrium fluctuation dissipation approach. We classify patients into different groups according to the patients' characteristics. For each patient group, we extend the fluctuation dissipation theorem to predict interactions between blood pressure and beat-to-beat dynamics of heart rate in response to a perturbation (SBT), We also extract the form of the perturbation function directly from the physiological data, which may help to reduce the prediction error. We note this method is not limited to the analysis of the heart rate dynamics, but also can be applied to analyze the response of other physiological signals to other clinical interventions.

  17. Assessing interactions among multiple physiological systems during walking outside a laboratory: An Android based gait monitor

    PubMed Central

    Sejdić, E.; Millecamps, A.; Teoli, J.; Rothfuss, M. A.; Franconi, N. G.; Perera, S.; Jones, A. K.; Brach, J. S.; Mickle, M. H.

    2015-01-01

    Gait function is traditionally assessed using well-lit, unobstructed walkways with minimal distractions. In patients with subclinical physiological abnormalities, these conditions may not provide enough stress on their ability to adapt to walking. The introduction of challenging walking conditions in gait can induce responses in physiological systems in addition to the locomotor system. There is a need for a device that is capable of monitoring multiple physiological systems in various walking conditions. To address this need, an Android-based gait-monitoring device was developed that enabled the recording of a patient's physiological systems during walking. The gait-monitoring device was tested during self-regulated overground walking sessions of fifteen healthy subjects that included 6 females and 9 males aged 18 to 35 years. The gait-monitoring device measures the patient's stride interval, acceleration, electrocardiogram, skin conductance and respiratory rate. The data is stored on an Android phone and is analyzed offline through the extraction of features in the time, frequency and time-frequency domains. The analysis of the data depicted multisystem physiological interactions during overground walking in healthy subjects. These interactions included locomotion-electrodermal, locomotion-respiratory and cardiolocomotion couplings. The current results depicting strong interactions between the locomotion system and the other considered systems (i.e., electrodermal, respiratory and cardivascular systems) warrant further investigation into multisystem interactions during walking, particularly in challenging walking conditions with older adults. PMID:26390946

  18. An intelligent health monitoring system using radio-frequency identification technology.

    PubMed

    Lai, Yeong-Lin; Chen, Chin-Ling; Chang, Ching-Hisang; Hsu, Chih-Yu; Lai, Yeong-Kang; Tseng, Kuo-Kun; Chen, Chih-Cheng; Zheng, Chun-Yi

    2015-01-01

    Long-term care (LTC) for the elderly has become extremely important in recent years. It is necessary for the different physiological monitoring systems to be integrated on the same interface to help oversee and manage the elderly's needs. This paper presents a novel health monitoring system for LTC services using radio-frequency identification (RFID) technology. Dual-band RFID protocols were included in the system, in which the high-frequency (HF) band of 13.56 MHz was used to identify individuals and the microwave band of 2.45 GHz was used to monitor physiological information. Distinct physiological data, including oxyhemoglobin saturation by pulse oximetry (SpO2), blood pressure, blood sugar, electrocardiogram (ECG) readings, body temperature, and respiration rate, were monitored by various biosensors. The intelligent RFID health monitoring system provided the features of the real-time acquisition of biomedical signals and the identification of personal information pertaining to the elderly and patients in nursing homes.

  19. [Construction and analysis of a monitoring system with remote real-time multiple physiological parameters based on cloud computing].

    PubMed

    Zhu, Lingyun; Li, Lianjie; Meng, Chunyan

    2014-12-01

    There have been problems in the existing multiple physiological parameter real-time monitoring system, such as insufficient server capacity for physiological data storage and analysis so that data consistency can not be guaranteed, poor performance in real-time, and other issues caused by the growing scale of data. We therefore pro posed a new solution which was with multiple physiological parameters and could calculate clustered background data storage and processing based on cloud computing. Through our studies, a batch processing for longitudinal analysis of patients' historical data was introduced. The process included the resource virtualization of IaaS layer for cloud platform, the construction of real-time computing platform of PaaS layer, the reception and analysis of data stream of SaaS layer, and the bottleneck problem of multi-parameter data transmission, etc. The results were to achieve in real-time physiological information transmission, storage and analysis of a large amount of data. The simulation test results showed that the remote multiple physiological parameter monitoring system based on cloud platform had obvious advantages in processing time and load balancing over the traditional server model. This architecture solved the problems including long turnaround time, poor performance of real-time analysis, lack of extensibility and other issues, which exist in the traditional remote medical services. Technical support was provided in order to facilitate a "wearable wireless sensor plus mobile wireless transmission plus cloud computing service" mode moving towards home health monitoring for multiple physiological parameter wireless monitoring.

  20. Implementation and Validation of a Real-Time Wireless Non-Invasive Physiological Monitoring System in a High-G Environment

    DTIC Science & Technology

    2003-03-01

    51 Figure 30. SpO2 vs G Profile...and physiological monitoring. The system will be composed of a shirt having non- invasive physiological sensors , Global Positioning System (GPS...Positioning System (GPS)), and other sensor technology. It is now possible to transmit large amounts of data at a high rate in real-time. These

  1. Towards 24/7 continuous heart rate monitoring.

    PubMed

    Tarniceriu, Adrian; Parak, Jakub; Renevey, Philippe; Nurmi, Marko; Bertschi, Mattia; Delgado-Gonzalo, Ricard; Korhonen, Ilkka

    2016-08-01

    Heart rate (HR) and HR variability (HRV) carry rich information about physical activity, mental and physical load, physiological status, and health of an individual. When combined with activity monitoring and personalized physiological modelling, HR/HRV monitoring may be used for monitoring of complex behaviors and impact of behaviors and external factors on the current physiological status of an individual. Optical HR monitoring (OHR) from wrist provides a comfortable and unobtrusive method for HR/HRV monitoring and is better adhered by users than traditional ECG electrodes or chest straps. However, OHR power consumption is significantly higher than that for ECG based methods due to the measurement principle based on optical illumination of the tissue. We developed an algorithmic approach to reduce power consumption of the OHR in 24/7 HR trending. We use continuous activity monitoring and a fast converging frequency domain algorithm to derive a reliable HR estimate in 7.1s (during outdoor sports, in average) to 10.0s (during daily life). The method allows >80% reduction in power consumption in 24/7 OHR monitoring when average HR monitoring is targeted, without significant reduction in tracking accuracy.

  2. [Monitoring of occupational activities under the risk of heat stress: use of mathematical models in the prediction of physiological parameters].

    PubMed

    Terzi, R; Catenacci, G; Marcaletti, G

    1985-01-01

    Some authors proposed mathematical models that, starting from standardized conditions of environmental microclimate parameters, thermal impedance of the clothing, and energetic expenditure allowed the forecast of the body temperature and heart rate variations in respect to the basal values in subjects standing in the same environment. In the present work we verify the usefulness of these models applied to the working tasks characterized by standardized job made under unfavourable thermal conditions. In subject working in an electric power station the values of the body temperature and heart rate are registered and compared with the values obtained by the application of the studied models. The results are discussed in view of the practical use.

  3. Remote in vivo stress assessment of aquatic animals with microencapsulated biomarkers for environmental monitoring

    NASA Astrophysics Data System (ADS)

    Gurkov, Anton; Shchapova, Ekaterina; Bedulina, Daria; Baduev, Boris; Borvinskaya, Ekaterina; Meglinski, Igor; Timofeyev, Maxim

    2016-11-01

    Remote in vivo scanning of physiological parameters is a major trend in the development of new tools for the fields of medicine and animal physiology. For this purpose, a variety of implantable optical micro- and nanosensors have been designed for potential medical applications. At the same time, the important area of environmental sciences has been neglected in the development of techniques for remote physiological measurements. In the field of environmental monitoring and related research, there is a constant demand for new effective and quick techniques for the stress assessment of aquatic animals, and the development of proper methods for remote physiological measurements in vivo may significantly increase the precision and throughput of analyses in this field. In the present study, we apply pH-sensitive microencapsulated biomarkers to remotely monitor the pH of haemolymph in vivo in endemic amphipods from Lake Baikal, and we compare the suitability of this technique for stress assessment with that of common biochemical methods. For the first time, we demonstrate the possibility of remotely detecting a change in a physiological parameter in an aquatic organism under ecologically relevant stressful conditions and show the applicability of techniques using microencapsulated biomarkers for remote physiological measurements in environmental monitoring.

  4. Clinical evaluation of a noninvasive alarm system for nocturnal hypoglycemia.

    PubMed

    Skladnev, Victor N; Ghevondian, Nejhdeh; Tarnavskii, Stanislav; Paramalingam, Nirubasini; Jones, Timothy W

    2010-01-01

    The aim of this study was to evaluate the performance of a prototype noninvasive alarm system (HypoMon) for the detection of nocturnal hypoglycemia. A prospective cohort study evaluated an alarm system that included a sensor belt, a radio frequency transmitter for chest belt signals, and a receiver. The receiver incorporated integrated "real-time" algorithms designed to recognize hypoglycemia "signatures" in the physiological parameters monitored by the sensor belt. Fifty-two children and young adults with type 1 diabetes mellitus (T1DM) participated in this blinded, prospective, in-clinic, overnight study. Participants had a mean age of 16 years (standard deviation 2.1, range 12-20 years) and were asked to follow their normal meal and insulin routines for the day of the study. Participants had physiological parameters monitored overnight by a single HypoMon system. Their BG levels were also monitored overnight at regular intervals via an intravenous cannula and read on two independent Yellow Springs Instruments analyzers. Hypoglycemia was not induced by any manipulations of diabetes management, rather the subjects were monitored overnight for "natural" occurrences of hypoglycemia. Performance analyses included comparing HypoMon system alarm times with allowed time windows associated with each hypoglycemic event. The primary recognition algorithm in the prototype alarm system performed at a level consistent with expectations based on prior user surveys. The HypoMon system correctly recognized 8 out of the 11 naturally occurring overnight hypoglycemic events and falsely alarmed on 13 out of the remaining 41 normal nights [sensitivity 73% (8/11), specificity 68% (28/41), positive predictive value 38%,negative predictive value 90%]. The prototype HypoMon shows potential as an adjunct method for noninvasive overnight monitoring for hypoglycemia events in young people with T1DM. 2010 Diabetes Technology Society.

  5. A biomedical sensor system for real-time monitoring of astronauts' physiological parameters during extra-vehicular activities.

    PubMed

    Fei, Ding-Yu; Zhao, Xiaoming; Boanca, Cosmin; Hughes, Esther; Bai, Ou; Merrell, Ronald; Rafiq, Azhar

    2010-07-01

    To design and test an embedded biomedical sensor system that can monitor astronauts' comprehensive physiological parameters, and provide real-time data display during extra-vehicle activities (EVA) in the space exploration. An embedded system was developed with an array of biomedical sensors that can be integrated into the spacesuit. Wired communications were tested for physiological data acquisition and data transmission to a computer mounted on the spacesuit during task performances simulating EVA sessions. The sensor integration, data collection and communication, and the real-time data monitoring were successfully validated in the NASA field tests. The developed system may work as an embedded system for monitoring health status during long-term space mission. Copyright 2010 Elsevier Ltd. All rights reserved.

  6. Molecular crowding favors reactivity of a human ribozyme under physiological ionic conditions.

    PubMed

    Strulson, Christopher A; Yennawar, Neela H; Rambo, Robert P; Bevilacqua, Philip C

    2013-11-19

    In an effort to relate RNA folding to function under cellular-like conditions, we monitored the self-cleavage reaction of the human hepatitis delta virus-like CPEB3 ribozyme in the background of physiological ionic concentrations and various crowding and cosolute agents. We found that at physiological free Mg(2+) concentrations (∼0.1-0.5 mM), both crowders and cosolutes stimulate the rate of self-cleavage, up to ∼6-fold, but that in 10 mM Mg(2+) (conditions widely used for in vitro ribozyme studies) these same additives have virtually no effect on the self-cleavage rate. We further observe a dependence of the self-cleavage rate on crowder size, wherein the level of rate stimulation is diminished for crowders larger than the size of the unfolded RNA. Monitoring effects of crowding and cosolute agents on rates in biological amounts of urea revealed additive-promoted increases at both low and high Mg(2+) concentrations, with a maximal stimulation of more than 10-fold and a rescue of the rate to its urea-free values. Small-angle X-ray scattering experiments reveal a structural basis for this stimulation in that higher-molecular weight crowding agents favor a more compact form of the ribozyme in 0.5 mM Mg(2+) that is essentially equivalent to the form under standard ribozyme conditions of 10 mM Mg(2+) without a crowder. This finding suggests that at least a portion of the rate enhancement arises from favoring the native RNA tertiary structure. We conclude that cellular-like crowding supports ribozyme reactivity by favoring a compact form of the ribozyme, but only under physiological ionic and cosolute conditions.

  7. Physiological response of rats to delivery of helium and xenon: implications for hyperpolarized noble gas imaging

    NASA Technical Reports Server (NTRS)

    Ramirez, M. P.; Sigaloff, K. C.; Kubatina, L. V.; Donahue, M. A.; Venkatesh, A. K.; Albert, M. S.; ALbert, M. S. (Principal Investigator)

    2000-01-01

    The physiological effects of various hyperpolarized helium and xenon MRI-compatible breathing protocols were investigated in 17 Sprague-Dawley rats, by continuous monitoring of blood oxygen saturation, heart rate, EKG, temperature and endotracheal pressure. The protocols included alternating breaths of pure noble gas and oxygen, continuous breaths of pure noble gas, breath-holds of pure noble gas for varying durations, and helium breath-holds preceded by two helium rinses. Alternate-breath protocols up to 128 breaths caused a decrease in oxygen saturation level of less than 5% for either helium or xenon, whereas 16 continuous-breaths caused a 31.5% +/- 2.3% decrease in oxygen saturation for helium and a 30.7% +/- 1. 3% decrease for xenon. Breath-hold protocols up to 25 s did not cause the oxygen saturation to fall below 90% for either of the noble gases. Oxygen saturation values below 90% are considered pathological. At 30 s of breath-hold, the blood oxygen saturation dropped precipitously to 82% +/- 0.6% for helium, and to 76.5% +/- 7. 4% for xenon. Breath-holds longer than 10 s preceded by pre-rinses caused oxygen saturation to drop below 90%. These findings demonstrate the need for standardized noble gas inhalation procedures that have been carefully tested, and for continuous physiological monitoring to ensure the safety of the subject. We find short breath-hold and alternate-breath protocols to be safe procedures for use in hyperpolarized noble gas MRI experiments. Copyright 2000 John Wiley & Sons, Ltd.

  8. Middle infrared optoelectronic absorption systems for monitoring physiological glucose solutions

    NASA Astrophysics Data System (ADS)

    Martin, W. Blake

    Tight monitoring of the glucose levels for diabetic individuals is essential to control long-term complications. A definitive diabetes management system has yet to be developed for the diabetic. This research investigates the application of middle infrared absorption frequencies for monitoring glucose levels in biological solutions. Three frequencies were identified using a Fourier transform infrared spectrometer and correlated to changes in glucose concentrations. The 1035 +/- 1 cm-1 frequency was determined to be the best representative frequency. Other biological molecules contributed no significant interference to monitoring glucose absorption. A second frequency at 1193 cm-1 was suggested as a representative background absorption frequency, which could be used for more accurate glucose absorption values. Next, a quantum cascade laser optoelectronic absorption system was designed and developed to monitor glucose. After careful alignment and design, the system was used to monitor physiological glucose concentrations. Correlation at 1036 cm-1 with glucose changes was comparable to the previous results. The use of the background absorption frequency was verified. This frequency essentially acts as a calibrating frequency to adjust in real-time to any changes in the background absorption that may alter the accuracy of the predicted glucose value. An evanescent wave cavity ring-down spectroscopy technique was explored to monitor molecules in a biological solution. Visible light at 425 nm was used to monitor hemoglobin in control urine samples. An adsorption isotherm for hemoglobin was detectable to limit of 5.8 nM. Evanescent wave cavity ring-down spectroscopy would be useful for a glucose solution. Given an equivalent system designed for the middle infrared, the molar extinction coefficient of glucose allows for a detectable limit of 45 mg/dl for a free-floating glucose solution, which is below normal physiological concentrations. The future use of a hydrophobic coating could limit the adsorption of glucose to the surface but still allow physiological monitoring. Three middle infrared optoelectronic absorption systems have been designed for monitoring glucose in a physiological solution. The systems are applicable for the monitoring of glucose. These systems may lead to a useful monitoring device for the diabetic so that the universal complications associated with the disease may be limited.

  9. Flexible Sensing Electronics for Wearable/Attachable Health Monitoring.

    PubMed

    Wang, Xuewen; Liu, Zheng; Zhang, Ting

    2017-07-01

    Wearable or attachable health monitoring smart systems are considered to be the next generation of personal portable devices for remote medicine practices. Smart flexible sensing electronics are components crucial in endowing health monitoring systems with the capability of real-time tracking of physiological signals. These signals are closely associated with body conditions, such as heart rate, wrist pulse, body temperature, blood/intraocular pressure and blood/sweat bio-information. Monitoring such physiological signals provides a convenient and non-invasive way for disease diagnoses and health assessments. This Review summarizes the recent progress of flexible sensing electronics for their use in wearable/attachable health monitoring systems. Meanwhile, we present an overview of different materials and configurations for flexible sensors, including piezo-resistive, piezo-electrical, capacitive, and field effect transistor based devices, and analyze the working principles in monitoring physiological signals. In addition, the future perspectives of wearable healthcare systems and the technical demands on their commercialization are briefly discussed. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Pulse Power--A Heart Physiology Program for Children.

    ERIC Educational Resources Information Center

    Hinson, Curt

    1994-01-01

    Primary grade students at a Delaware elementary school currently participate in the Pulse Power heart physiology program. Students receive mastery instruction and use heart monitors to exercise performance throughout the 6-phase program. Data from homework and from the heart monitors identify student progress, knowledge, and cardiovascular…

  11. Real time monitoring to the odour of excrement for health of infants and elderly completely bedridden

    NASA Astrophysics Data System (ADS)

    Ye, Jiancheng; Huang, Guoliang

    2017-01-01

    In the domain of biomedical signals measurements, monitoring human physiological parameters is an important issue. With the rapid development of wireless body area network, it makes monitor, transmit and record physiological parameters faster and more convenient. Infants and the elderly completely bedridden are two special groups of the society who need more medical care. According to researches investigating current frontier domains and the market products, the detection of physiological parameters from the excrement is rare. However, urine and faeces contain a large number of physiological information, which are high relative to health. The mainly distributed odour from urine is NH4 and the distributed odour from feces is mainly H2S, which are both could be detected by the sensors. In this paper, we introduce the design and implementation of a portable wireless device based on body area network for real time monitoring to the odour of excrement for health of infants and the elderly completely bedridden. The device not only could monitor in real time the emitted odour of faeces and urine for health analysis, but also measures the body temperature and environment humidity, and send data to the mobile phone of paramedics to alarm or the server for storage and process, which has prospect to monitoring infants and the paralysis elderly.

  12. A new integrated instrumental approach to autonomic nervous system assessment.

    PubMed

    Corazza, I; Barletta, G; Guaraldi, P; Cecere, A; Calandra-Buonaura, G; Altini, E; Zannoli, R; Cortelli, P

    2014-11-01

    The autonomic nervous system (ANS) regulates involuntary body functions and is commonly evaluated by measuring reflex responses of systolic and diastolic blood pressure (BP) and heart rate (HR) to physiological and pharmacological stimuli. However, BP and HR values may not sufficient be to explain specific ANS events and other parameters like the electrocardiogram (ECG), BP waves, the respiratory rate and the electroencephalogram (EEG) are mandatory. Although ANS behaviour and its response to stimuli are well-known, their clinical evaluation is often based on individual medical training and experience. As a result, ANS laboratories have been customized, making it impossible to standardize procedures and share results with colleagues. The aim of our study was to build a powerful versatile instrument easy-to-use in clinical practice to standardize procedures and allow a cross-analysis of all the parameters of interest for ANS evaluation. The new ANScovery System developed by neurologists and technicians is a two-step device: (1) integrating physiological information from different already existing commercial modules, making it possible to cross-analyse, store and share data; (2) standardizing procedures by an innovative tutor monitor able to guide the patient throughout ANS testing. The daily use of the new ANScovery System in clinical practice has proved it is a versatile easy to use instrument. Standardization of the manoeuvres and step-by-step guidance throughout the procedure avoid repetitions and allow intra and inter-patient data comparison. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  13. Lung function imaging methods in Cystic Fibrosis pulmonary disease.

    PubMed

    Kołodziej, Magdalena; de Veer, Michael J; Cholewa, Marian; Egan, Gary F; Thompson, Bruce R

    2017-05-17

    Monitoring of pulmonary physiology is fundamental to the clinical management of patients with Cystic Fibrosis. The current standard clinical practise uses spirometry to assess lung function which delivers a clinically relevant functional readout of total lung function, however does not supply any visible or localised information. High Resolution Computed Tomography (HRCT) is a well-established current 'gold standard' method for monitoring lung anatomical changes in Cystic Fibrosis patients. HRCT provides excellent morphological information, however, the X-ray radiation dose can become significant if multiple scans are required to monitor chronic diseases such as cystic fibrosis. X-ray phase-contrast imaging is another emerging X-ray based methodology for Cystic Fibrosis lung assessment which provides dynamic morphological and functional information, albeit with even higher X-ray doses than HRCT. Magnetic Resonance Imaging (MRI) is a non-ionising radiation imaging method that is garnering growing interest among researchers and clinicians working with Cystic Fibrosis patients. Recent advances in MRI have opened up the possibilities to observe lung function in real time to potentially allow sensitive and accurate assessment of disease progression. The use of hyperpolarized gas or non-contrast enhanced MRI can be tailored to clinical needs. While MRI offers significant promise it still suffers from poor spatial resolution and the development of an objective scoring system especially for ventilation assessment.

  14. A portable measuring system for a competitive binding glucose biosensor

    NASA Astrophysics Data System (ADS)

    Colvin, Lydia E.; Means, A. Kristen; Grunlan, Melissa A.; Coté, Gerard L.

    2018-02-01

    Central to minimizing the long- and short-term complications associated with diabetes is careful monitoring and maintenance of blood glucose at normal levels. Towards replacing conventionally used finger-prick glucose testing, indwelling continuous glucose monitors (CGMs) based on amperometric electrodes have been introduced to the market. Envisioned to lead to a CGM with an increased lifetime, we report herein a fluorescently-labeled competitive binding assay contained within a hydrogel membrane whose glucose response is measured via a novel portable system. The optical system design included a laser source, bifurcated fiber, laser filter and simple fiber coupled spectrometer to obtain the change in FRET pair ratio of the assay. Glucose response of the assay in free solution was measured using this system across the physiologic range (0-200 mg/dL). The FRET pair ratio signal was seen to increase with glucose and the standard error of calibration was 22.42 mg/dL with a MARD value of 14.85%. When the assay was contained within the hydrogel membrane's central cavity and similarly analyzed, the standard error increased but the assay maintained its reversibility.

  15. Physiological Modalities for Relaxation Skill Transfer in Biofeedback Games.

    PubMed

    Parnandi, Avinash; Gutierrez-Osuna, Ricardo

    2017-03-01

    We present an adaptive biofeedback game for teaching self-regulation of stress. Our approach consists of monitoring the user's physiology during gameplay and adapting the game using a positive feedback loop that rewards relaxing behaviors and penalizes states of high arousal. We evaluate the approach using a casual game under three biofeedback modalities: electrodermal activity, heart rate variability, and breathing rate. The three biosignals can be measured noninvasively with wearable sensors, and represent different degrees of voluntary control and selectivity toward arousal. We conducted an experiment trial with 25 participants to compare the three modalities against a standard treatment (deep breathing) and a control condition (the game without biofeedback). Our results indicate that breathing-based game biofeedback is more effective in inducing relaxation during treatment than the other four groups. Participants in this group also showed greater retention of the relaxation skills (without biofeedback) during a subsequent stressor.

  16. High-resolution Mass Spectrometry of Skin Mucus for Monitoring Physiological Impacts in Fish Exposed to Wastewater Effluent at a Great Lakes AOC

    EPA Science Inventory

    High-resolution mass spectrometry is advantageous for monitoring physiological impacts and contaminant biotransformation products in fish exposed to complex wastewater effluent. We evaluated this technique using skin mucus from male and female fathead minnows (Pimephales promela...

  17. High‐resolution mass spectrometry of skin mucus for monitoring physiological impacts and contaminant biotransformation products in fathead minnows exposed to wastewater effluent

    EPA Science Inventory

    High‐resolution mass spectrometry is advantageous for monitoring physiological impacts and contaminant biotransformation products in fish exposed to complex wastewater effluent. We evaluated this technique using skin mucus from male and female fathead minnows (Pimephales pr...

  18. Recent Developments in Home Sleep-Monitoring Devices

    PubMed Central

    Kelly, Jessica M.; Strecker, Robert E.; Bianchi, Matt T.

    2012-01-01

    Improving our understanding of sleep physiology and pathophysiology is an important goal for both medical and general wellness reasons. Although the gold standard for assessing sleep remains the laboratory polysomnogram, there is an increasing interest in portable monitoring devices that provide the opportunity for assessing sleep in real-world environments such as the home. Portable devices allow repeated measurements, evaluation of temporal patterns, and self-experimentation. We review recent developments in devices designed to monitor sleep-wake activity, as well as monitors designed for other purposes that could in principle be applied in the field of sleep (such as cardiac or respiratory sensing). As the body of supporting validation data grows, these devices hold promise for a variety of health and wellness goals. From a clinical and research standpoint, the capacity to obtain longitudinal sleep-wake data may improve disease phenotyping, individualized treatment decisions, and individualized health optimization. From a wellness standpoint, commercially available devices may allow individuals to track their own sleep with the goal of finding patterns and correlations with modifiable behaviors such as exercise, diet, and sleep aids. PMID:23097718

  19. A wireless PDA-based physiological monitoring system for patient transport.

    PubMed

    Lin, Yuan-Hsiang; Jan, I-Chien; Ko, Patrick Chow-In; Chen, Yen-Yu; Wong, Jau-Min; Jan, Gwo-Jen

    2004-12-01

    This paper proposes a mobile patient monitoring system, which integrates current personal digital assistant (PDA) technology and wireless local area network (WLAN) technology. At the patient's location, a wireless PDA-based monitor is used to acquire continuously the patient's vital signs, including heart rate, three-lead electrocardiography, and SpO2. Through the WLAN, the patient's biosignals can be transmitted in real-time to a remote central management unit, and authorized medical staffs can access the data and the case history of the patient, either by the central management unit or the wireless devices. A prototype of this system has been developed and implemented. The system has been evaluated by technical verification, clinical test, and user survey. The evaluation of performance yields a high degree of satisfaction (mean = 4.64, standard deviation--SD = 0.53 in a five-point Likert scale) of users who used the PDA-based system for intrahospital transport. The results also show that the wireless PDA model is superior to the currently used monitors both in mobility and in usability, and is, therefore, better suited to patient transport.

  20. Smart sensor systems for human health breath monitoring applications.

    PubMed

    Hunter, G W; Xu, J C; Biaggi-Labiosa, A M; Laskowski, D; Dutta, P K; Mondal, S P; Ward, B J; Makel, D B; Liu, C C; Chang, C W; Dweik, R A

    2011-09-01

    Breath analysis techniques offer a potential revolution in health care diagnostics, especially if these techniques can be brought into standard use in the clinic and at home. The advent of microsensors combined with smart sensor system technology enables a new generation of sensor systems with significantly enhanced capabilities and minimal size, weight and power consumption. This paper discusses the microsensor/smart sensor system approach and provides a summary of efforts to migrate this technology into human health breath monitoring applications. First, the basic capability of this approach to measure exhaled breath associated with exercise physiology is demonstrated. Building from this foundation, the development of a system for a portable asthma home health care system is described. A solid-state nitric oxide (NO) sensor for asthma monitoring has been identified, and efforts are underway to miniaturize this NO sensor technology and integrate it into a smart sensor system. It is concluded that base platform microsensor technology combined with smart sensor systems can address the needs of a range of breath monitoring applications and enable new capabilities for healthcare.

  1. Telemetry methods for monitoring physiological parameters

    NASA Technical Reports Server (NTRS)

    Fryer, T. B.; Sandler, H.

    1982-01-01

    The use of telemetry to monitor various physiological functions is discussed. The advantages of the technique and the parameters that it can monitor are assessed, and the main telemetry systems, including pressure telemetry, flow telemetry, and multichannel telemetry, are detailed. Human applications of implanted flow transducers, total implant versus backpack telemetry, the use of power sources and integrated circuits in telemetry, and the future prospects of the technique in hypertension treatment and research are discussed.

  2. Specifications Physiological Monitoring System

    NASA Technical Reports Server (NTRS)

    1985-01-01

    The operation of a physiological monitoring system (PMS) is described. Specifications were established for performance, design, interface, and test requirements. The PMS is a compact, microprocessor-based system, which can be worn in a pack on the body or may be mounted on a Spacelab rack or other appropriate structure. It consists of two modules, the Data Control Unit (DCU) and the Remote Control/Display Unit (RCDU). Its purpose is to collect and distribute data from physiological experiments in the Spacelab and in the Orbiter.

  3. Novel use of a noninvasive hemodynamic monitor in a personalized, active learning simulation.

    PubMed

    Zoller, Jonathan K; He, Jianghua; Ballew, Angela T; Orr, Walter N; Flynn, Brigid C

    2017-06-01

    The present study furthered the concept of simulation-based medical education by applying a personalized active learning component. We tested this novel approach utilizing a noninvasive hemodynamic monitor with the capability to measure and display in real time numerous hemodynamic parameters in the exercising participant. Changes in medical knowledge concerning physiology were examined with a pre-and posttest. Simply by observation of one's own hemodynamic variables, the understanding of complex physiological concepts was significantly enhanced. Copyright © 2017 the American Physiological Society.

  4. Basic principles of respiratory function monitoring in ventilated newborns: A review.

    PubMed

    Schmalisch, Gerd

    2016-09-01

    Respiratory monitoring during mechanical ventilation provides a real-time picture of patient-ventilator interaction and is a prerequisite for lung-protective ventilation. Nowadays, measurements of airflow, tidal volume and applied pressures are standard in neonatal ventilators. The measurement of lung volume during mechanical ventilation by tracer gas washout techniques is still under development. The clinical use of capnography, although well established in adults, has not been embraced by neonatologists because of technical and methodological problems in very small infants. While the ventilatory parameters are well defined, the calculation of other physiological parameters are based upon specific assumptions which are difficult to verify. Incomplete knowledge of the theoretical background of these calculations and their limitations can lead to incorrect interpretations with clinical consequences. Therefore, the aim of this review was to describe the basic principles and the underlying assumptions of currently used methods for respiratory function monitoring in ventilated newborns and to highlight methodological limitations. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. [Limits of cardiac functional adaptation in "top level" resistance athletes].

    PubMed

    Carù, B; Righetti, G; Bossi, M; Gerosa, C; Gazzotti, G; Maranetto, D

    2001-02-01

    Sports activity, particularly when performed at high level, provokes cardiovascular adjustments depending on the type of sport and on the level of the load. We evaluated 15 athletes from the Italian national team during a non-agonistic period of cross country skiing, with non-invasive tests including exercise test, color Doppler echocardiography, Holter monitoring, physical examination and standard rest electrocardiogram. Physical examination, rest electrocardiogram, exercise testing and echocardiography were all within the range of the expected values for this type of subjects. Holter monitoring recorded during the periods of agonistic activity revealed significant hypokinetic arrhythmias such as severe bradycardia, pauses, I and II degree atrioventricular blocks, and complete atrioventricular block in 2 cases; these features were not observed on Holter monitoring recorded during the non-agonistic period. The perfect health status of subjects and their racing results may bring about physiological functional adjustments, but these observations suggest the need for a follow-up to evaluate possible pathologic outcomes.

  6. Detection of essential hypertension with physiological signals from wearable devices.

    PubMed

    Ghosh, Arindam; Torres, Juan Manuel Mayor; Danieli, Morena; Riccardi, Giuseppe

    2015-08-01

    Early detection of essential hypertension can support the prevention of cardiovascular disease, a leading cause of death. The traditional method of identification of hypertension involves periodic blood pressure measurement using brachial cuff-based measurement devices. While these devices are non-invasive, they require manual setup for each measurement and they are not suitable for continuous monitoring. Research has shown that physiological signals such as Heart Rate Variability, which is a measure of the cardiac autonomic activity, is correlated with blood pressure. Wearable devices capable of measuring physiological signals such as Heart Rate, Galvanic Skin Response, Skin Temperature have recently become ubiquitous. However, these signals are not accurate and are prone to noise due to different artifacts. In this paper a) we present a data collection protocol for continuous non-invasive monitoring of physiological signals from wearable devices; b) we implement signal processing techniques for signal estimation; c) we explore how the continuous monitoring of these physiological signals can be used to identify hypertensive patients; d) We conduct a pilot study with a group of normotensive and hypertensive patients to test our techniques. We show that physiological signals extracted from wearable devices can distinguish between these two groups with high accuracy.

  7. Assessment of Body Weight Standards in Male and Female Army Recruits

    DTIC Science & Technology

    1989-12-29

    OF ENVIRONMENTAL MEDICINE Natick, Massachusetts DTIC` h tj1LECTF’S&I L19 1gu A p p to@ 4 d lo t p u b li c f hlo .. d t t hb u lio " uY lim i led...RECRUITS K.E. Fried’, Pit.D. J.A. Vogsl, Ph.D. M.W. Bovee iB.H. Jones, M.D. Exercise Physiology Division US Army Research Institute of Environmental ...MONITORING ORGANIZATION U.S. Army Research Institute (If applicable) of Environmental Medicine SGRD-UE-PH 6c. ADDRESS (City, State, and ZIPCodte 7b

  8. Recent advancement in biosensors technology for animal and livestock health management.

    PubMed

    Neethirajan, Suresh; Tuteja, Satish K; Huang, Sheng-Tung; Kelton, David

    2017-12-15

    The term biosensors encompasses devices that have the potential to quantify physiological, immunological and behavioural responses of livestock and multiple animal species. Novel biosensing methodologies offer highly specialised monitoring devices for the specific measurement of individual and multiple parameters covering an animal's physiology as well as monitoring of an animal's environment. These devices are not only highly specific and sensitive for the parameters being analysed, but they are also reliable and easy to use, and can accelerate the monitoring process. Novel biosensors in livestock management provide significant benefits and applications in disease detection and isolation, health monitoring and detection of reproductive cycles, as well as monitoring physiological wellbeing of the animal via analysis of the animal's environment. With the development of integrated systems and the Internet of Things, the continuously monitoring devices are expected to become affordable. The data generated from integrated livestock monitoring is anticipated to assist farmers and the agricultural industry to improve animal productivity in the future. The data is expected to reduce the impact of the livestock industry on the environment, while at the same time driving the new wave towards the improvements of viable farming techniques. This review focusses on the emerging technological advancements in monitoring of livestock health for detailed, precise information on productivity, as well as physiology and well-being. Biosensors will contribute to the 4th revolution in agriculture by incorporating innovative technologies into cost-effective diagnostic methods that can mitigate the potentially catastrophic effects of infectious outbreaks in farmed animals. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Effect of neuromonitor-guided titrated care on brain tissue hypoxia after opioid overdose cardiac arrest.

    PubMed

    Elmer, Jonathan; Flickinger, Katharyn L; Anderson, Maighdlin W; Koller, Allison C; Sundermann, Matthew L; Dezfulian, Cameron; Okonkwo, David O; Shutter, Lori A; Salcido, David D; Callaway, Clifton W; Menegazzi, James J

    2018-04-18

    Brain tissue hypoxia may contribute to preventable secondary brain injury after cardiac arrest. We developed a porcine model of opioid overdose cardiac arrest and post-arrest care including invasive, multimodal neurological monitoring of regional brain physiology. We hypothesized brain tissue hypoxia is common with usual post-arrest care and can be prevented by modifying mean arterial pressure (MAP) and arterial oxygen concentration (PaO 2 ). We induced opioid overdose and cardiac arrest in sixteen swine, attempted resuscitation after 9 min of apnea, and randomized resuscitated animals to three alternating 6-h blocks of standard or titrated care. We invasively monitored physiological parameters including brain tissue oxygen (PbtO 2 ). During standard care blocks, we maintained MAP > 65 mmHg and oxygen saturation 94-98%. During titrated care, we targeted PbtO2 > 20 mmHg. Overall, 10 animals (63%) achieved ROSC after a median of 12.4 min (range 10.8-21.5 min). PbtO 2 was higher during titrated care than standard care blocks (unadjusted β = 0.60, 95% confidence interval (CI) 0.42-0.78, P < 0.001). In an adjusted model controlling for MAP, vasopressors, sedation, and block sequence, PbtO 2 remained higher during titrated care (adjusted β = 0.75, 95%CI 0.43-1.06, P < 0.001). At three predetermined thresholds, brain tissue hypoxia was significantly less common during titrated care blocks (44 vs 2% of the block duration spent below 20 mmHg, P < 0.001; 21 vs 0% below 15 mmHg, P < 0.001; and, 7 vs 0% below 10 mmHg, P = .01). In this model of opioid overdose cardiac arrest, brain tissue hypoxia is common and treatable. Further work will elucidate best strategies and impact of titrated care on functional outcomes. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. [Telemetry in the clinical setting].

    PubMed

    Hilbel, Thomas; Helms, Thomas M; Mikus, Gerd; Katus, Hugo A; Zugck, Christian

    2008-09-01

    Telemetric cardiac monitoring was invented in 1949 by Norman J Holter. Its clinical use started in the early 1960s. In the hospital, biotelemetry allows early mobilization of patients with cardiovascular risk and addresses the need for arrhythmia or oxygen saturation monitoring. Nowadays telemetry either uses vendor-specific UHF band broadcasting or the digital ISM band (Industrial, Scientific, and Medical Band) standardized Wi-Fi network technology. Modern telemetry radio transmitters can measure and send multiple physiological parameters like multi-channel ECG, NIPB and oxygen saturation. The continuous measurement of oxygen saturation is mandatory for the remote monitoring of patients with cardiac pacemakers. Real 12-lead ECG systems with diagnostic quality are an advantage for monitoring patients with chest pain syndromes or in drug testing wards. Modern systems are light-weight and deliver a maximum of carrying comfort due to optimized cable design. Important for the system selection is a sophisticated detection algorithm with a maximum reduction of artifacts. Home-monitoring of implantable cardiac devices with telemetric functionalities are becoming popular because it allows remote diagnosis of proper device functionality and also optimization of the device settings. Continuous real-time monitoring at home for patients with chronic disease may be possible in the future using Digital Video Broadcasting Terrestrial (DVB-T) technology in Europe, but is currently not yet available.

  11. Functionality of empirical model-based predictive analytics for the early detection of hemodynamic instabilty.

    PubMed

    Summers, Richard L; Pipke, Matt; Wegerich, Stephan; Conkright, Gary; Isom, Kristen C

    2014-01-01

    Background. Monitoring cardiovascular hemodynamics in the modern clinical setting is a major challenge. Increasing amounts of physiologic data must be analyzed and interpreted in the context of the individual patient’s pathology and inherent biologic variability. Certain data-driven analytical methods are currently being explored for smart monitoring of data streams from patients as a first tier automated detection system for clinical deterioration. As a prelude to human clinical trials, an empirical multivariate machine learning method called Similarity-Based Modeling (“SBM”), was tested in an In Silico experiment using data generated with the aid of a detailed computer simulator of human physiology (Quantitative Circulatory Physiology or “QCP”) which contains complex control systems with realistic integrated feedback loops. Methods. SBM is a kernel-based, multivariate machine learning method that that uses monitored clinical information to generate an empirical model of a patient’s physiologic state. This platform allows for the use of predictive analytic techniques to identify early changes in a patient’s condition that are indicative of a state of deterioration or instability. The integrity of the technique was tested through an In Silico experiment using QCP in which the output of computer simulations of a slowly evolving cardiac tamponade resulted in progressive state of cardiovascular decompensation. Simulator outputs for the variables under consideration were generated at a 2-min data rate (0.083Hz) with the tamponade introduced at a point 420 minutes into the simulation sequence. The functionality of the SBM predictive analytics methodology to identify clinical deterioration was compared to the thresholds used by conventional monitoring methods. Results. The SBM modeling method was found to closely track the normal physiologic variation as simulated by QCP. With the slow development of the tamponade, the SBM model are seen to disagree while the simulated biosignals in the early stages of physiologic deterioration and while the variables are still within normal ranges. Thus, the SBM system was found to identify pathophysiologic conditions in a timeframe that would not have been detected in a usual clinical monitoring scenario. Conclusion. In this study the functionality of a multivariate machine learning predictive methodology that that incorporates commonly monitored clinical information was tested using a computer model of human physiology. SBM and predictive analytics were able to differentiate a state of decompensation while the monitored variables were still within normal clinical ranges. This finding suggests that the SBM could provide for early identification of a clinical deterioration using predictive analytic techniques. predictive analytics, hemodynamic, monitoring.

  12. RFID Technology for Continuous Monitoring of Physiological Signals in Small Animals.

    PubMed

    Volk, Tobias; Gorbey, Stefan; Bhattacharyya, Mayukh; Gruenwald, Waldemar; Lemmer, Björn; Reindl, Leonhard M; Stieglitz, Thomas; Jansen, Dirk

    2015-02-01

    Telemetry systems enable researchers to continuously monitor physiological signals in unrestrained, freely moving small rodents. Drawbacks of common systems are limited operation time, the need to house the animals separately, and the necessity of a stable communication link. Furthermore, the costs of the typically proprietary telemetry systems reduce the acceptance. The aim of this paper is to introduce a low-cost telemetry system based on common radio frequency identification technology optimized for battery-independent operational time, good reusability, and flexibility. The presented implant is equipped with sensors to measure electrocardiogram, arterial blood pressure, and body temperature. The biological signals are transmitted as digital data streams. The device is able of monitoring several freely moving animals housed in groups with a single reader station. The modular concept of the system significantly reduces the costs to monitor multiple physiological functions and refining procedures in preclinical research.

  13. Non-contact physiological signal detection using continuous wave Doppler radar.

    PubMed

    Qiao, Dengyu; He, Tan; Hu, Boping; Li, Ye

    2014-01-01

    The aim of this work is to show non-contact physiological signal monitoring system based on continuous-wave (CW) Doppler radar, which is becoming highly attractive in the field of health care monitoring of elderly people. Two radar signal processing methods were introduced in this paper: one to extract respiration and heart rates of a single person and the other to separate mixed respiration signals. To verify the validity of the methods, physiological signal is obtained from stationary human subjects using a CW Doppler radar unit. The sensor operating at 24 GHz is located 0.5 meter away from the subject. The simulation results show that the respiration and heart rates are clearly extracted, and the mixed respiration signals are successfully separated. Finally, reference respiration and heart rate signals are measured by an ECG monitor and compared with the results tracked by the CW Doppler radar monitoring system.

  14. Real-Time Management of Multimodal Streaming Data for Monitoring of Epileptic Patients.

    PubMed

    Triantafyllopoulos, Dimitrios; Korvesis, Panagiotis; Mporas, Iosif; Megalooikonomou, Vasileios

    2016-03-01

    New generation of healthcare is represented by wearable health monitoring systems, which provide real-time monitoring of patient's physiological parameters. It is expected that continuous ambulatory monitoring of vital signals will improve treatment of patients and enable proactive personal health management. In this paper, we present the implementation of a multimodal real-time system for epilepsy management. The proposed methodology is based on a data streaming architecture and efficient management of a big flow of physiological parameters. The performance of this architecture is examined for varying spatial resolution of the recorded data.

  15. Identification of complex metabolic states in critically injured patients using bioinformatic cluster analysis.

    PubMed

    Cohen, Mitchell J; Grossman, Adam D; Morabito, Diane; Knudson, M Margaret; Butte, Atul J; Manley, Geoffrey T

    2010-01-01

    Advances in technology have made extensive monitoring of patient physiology the standard of care in intensive care units (ICUs). While many systems exist to compile these data, there has been no systematic multivariate analysis and categorization across patient physiological data. The sheer volume and complexity of these data make pattern recognition or identification of patient state difficult. Hierarchical cluster analysis allows visualization of high dimensional data and enables pattern recognition and identification of physiologic patient states. We hypothesized that processing of multivariate data using hierarchical clustering techniques would allow identification of otherwise hidden patient physiologic patterns that would be predictive of outcome. Multivariate physiologic and ventilator data were collected continuously using a multimodal bioinformatics system in the surgical ICU at San Francisco General Hospital. These data were incorporated with non-continuous data and stored on a server in the ICU. A hierarchical clustering algorithm grouped each minute of data into 1 of 10 clusters. Clusters were correlated with outcome measures including incidence of infection, multiple organ failure (MOF), and mortality. We identified 10 clusters, which we defined as distinct patient states. While patients transitioned between states, they spent significant amounts of time in each. Clusters were enriched for our outcome measures: 2 of the 10 states were enriched for infection, 6 of 10 were enriched for MOF, and 3 of 10 were enriched for death. Further analysis of correlations between pairs of variables within each cluster reveals significant differences in physiology between clusters. Here we show for the first time the feasibility of clustering physiological measurements to identify clinically relevant patient states after trauma. These results demonstrate that hierarchical clustering techniques can be useful for visualizing complex multivariate data and may provide new insights for the care of critically injured patients.

  16. Metabolic products as biomarkers

    USGS Publications Warehouse

    Melancon, M.J.; Alscher, R.; Benson, W.; Kruzynski, G.; Lee, R.F.; Sikka, H.C.; Spies, R.B.; Huggett, Robert J.; Kimerle, Richard A.; Mehrle, Paul M.=; Bergman, Harold L.

    1992-01-01

    Ideally, endogenous biomarkers would indicate both exposure and environmental effects of toxic chemicals; however, such comprehensive biochemical and physiological indices are currently being developed and, at the present time, are unavailable for use in environmental monitoring programs. Continued work is required to validate the use of biochemical and physiological stress indices as useful components of monitoring programs. Of the compounds discussed only phytochelatins and porphyrins are currently in biomarkers in a useful state; however, glutathione,metallothioneins, stress ethylene, and polyamines are promising as biomarkers in environmental monitoring.

  17. Assessing very high resolution UAV imagery for monitoring forest health during a simulated disease outbreak

    NASA Astrophysics Data System (ADS)

    Dash, Jonathan P.; Watt, Michael S.; Pearse, Grant D.; Heaphy, Marie; Dungey, Heidi S.

    2017-09-01

    Research into remote sensing tools for monitoring physiological stress caused by biotic and abiotic factors is critical for maintaining healthy and highly-productive plantation forests. Significant research has focussed on assessing forest health using remotely sensed data from satellites and manned aircraft. Unmanned aerial vehicles (UAVs) may provide new tools for improved forest health monitoring by providing data with very high temporal and spatial resolutions. These platforms also pose unique challenges and methods for health assessments must be validated before use. In this research, we simulated a disease outbreak in mature Pinus radiata D. Don trees using targeted application of herbicide. The objective was to acquire a time-series simulated disease expression dataset to develop methods for monitoring physiological stress from a UAV platform. Time-series multi-spectral imagery was acquired using a UAV flown over a trial at regular intervals. Traditional field-based health assessments of crown health (density) and needle health (discolouration) were carried out simultaneously by experienced forest health experts. Our results showed that multi-spectral imagery collected from a UAV is useful for identifying physiological stress in mature plantation trees even during the early stages of tree stress. We found that physiological stress could be detected earliest in data from the red edge and near infra-red bands. In contrast to previous findings, red edge data did not offer earlier detection of physiological stress than the near infra-red data. A non-parametric approach was used to model physiological stress based on spectral indices and was found to provide good classification accuracy (weighted kappa = 0.694). This model can be used to map physiological stress based on high-resolution multi-spectral data.

  18. AN AUTOMATED MONITORING SYSTEM FOR FISH PHYSIOLOGY AND TOXICOLOGY

    EPA Science Inventory

    This report describes a data acquisition and control (DAC) system that was constructed to manage selected physiological measurements and sample control for aquatic physiology and toxicology. Automated DAC was accomplished with a microcomputer running menu-driven software develope...

  19. Virtual Reality in Health System: Beyond Entertainment. A Mini-Review on the Efficacy of VR During Cancer Treatment.

    PubMed

    Chirico, Andrea; Lucidi, Fabio; De Laurentiis, Michele; Milanese, Carla; Napoli, Alessandro; Giordano, Antonio

    2016-02-01

    Virtual reality (VR), a computer-generated virtual environment, has been increasingly used in the entertainment world becoming a very new evolving field, but VR technology has also found a variety of applications in the biomedical field. VR can offer to subjects a safe environment within which to carry on different interventions ranging from the rehabilitation of discharged patients directly at home, to the support of hospitalized patients during different procedures and also of oncological inpatient subjects. VR appears as a promising tool for support and monitoring treatments in cancer patients influencing psychological and physiological functions. The aim of this systematic review is to provide an overview of all the studies that used VR intervention on cancer patients and analyze their main findings. Nineteen studies across nearly a thousand articles were identified that explored effects of VR interventions on cancer patients. Although these studies varied greatly in setting and design, this review identified some overarching themes. Results found that VR improved patients' emotional well-being, and diminished cancer-related psychological symptoms. The studies explored various relevant variables including different types of settings (i.e., during chemotherapy, during pain procedures, during hospitalization). Here, we point to the need of a global and multi-disciplinary approach aimed at analyzing the effects of VR taking advantage of the new technology systems like biosensors as well as electroencephalogram monitoring pre, during, and after intervention. Devoting more attention to bio-physiological variables, standardized procedures, extending duration to longitudinal studies and adjusting for motion sickness related to VR treatment need to become standard of this research field. © 2015 Wiley Periodicals, Inc.

  20. Remote physiological monitoring in an austere environment: a future for battlefield care provision?

    PubMed

    Smyth, Matthew J; Round, J A; Mellor, A J

    2018-05-14

    Wearable technologies are making considerable advances into the mainstream as they become smaller and more user friendly. The global market for such devices is forecasted to be worth over US$5 billion in 2018, with one in six people owning a device. Many professional sporting teams use self-monitoring to assess physiological parameters and work rate on the pitch, highlighting the potential utility for military command chains. As size of device reduces and sensitivity improves, coupled with remote connectivity technology, integration into the military environment could be relatively seamless. Remote monitoring of personnel on the ground, giving live updates on their physiological status, would allow commanders or medical officers the ability to manage their soldiers appropriately and improve combat effectiveness. This paper explores a proof of concept for the use of a self-monitoring system in the austere high altitude environment of the Nepalese Himalayas, akin to those experienced by modern militaries fighting in remote locations. It also reviews, in part, the historical development of remote monitoring technologies. The system allowed for physiological recordings, plotted against GPS position, to be remotely monitored in Italy. Examples of the data recorded are given and the performance of the system is discussed, including limitations, potential areas of development and how systems like this one could be integrated into the military environment. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  1. Examining physiological responses across different driving maneuvers during an on-road driving task: a pilot study comparing older and younger drivers.

    PubMed

    Koppel, S; Kuo, J; Berecki-Gisolf, J; Boag, R; Hue, Y-X; Charlton, J L

    2015-01-01

    This pilot study aimed to investigate physiological responses during an on-road driving task for older and younger drivers. Five older drivers (mean age = 74.60 years [2.97]) and 5 younger drivers (mean age = 30.00 years [3.08]) completed a series of cognitive assessments (Montreal Cognitive Assessment [MoCA], Mini Mental Status Examination [MMSE]; Trail Making Test [Trails A and Trails B]) and an on-road driving task along a predetermined, standardized urban route in their own vehicle. Driving performance was observed and scored by a single trained observer using a standardized procedure, where driving behaviors (appropriate and inappropriate) were scored for intersection negotiation, lane changing, and merging. During the on-road driving task, participants' heart rate (HR) was monitored with an unobtrusive physiological monitor. Younger drivers performed significantly better on all cognitive assessments compared to older drivers (MoCA: t(8) = 3.882, P <.01; MMSE: t(8) = 2.954, P <.05; Trails A: t(8) = -2.499, P <.05; Trails B: t(8) = -3.262, P <.05). Analyses of participants' performance during the on-road driving task revealed a high level of appropriate overall driving behavior (M = 87%, SD = 7.62, range = 73-95%), including intersection negotiation (M = 89%, SD = 8.37%), lane changing (M = 100%), and merging (M = 53%, SD = 28.28%). The overall proportion of appropriate driving behavior did not significantly differ across age groups (younger drivers: M = 87.6%, SD = 9.04; older drivers: M = 87.0%, SD = 6.96; t(8) = 0.118, P =.91). Although older drivers scored lower than younger drivers on the cognitive assessments, there was no indication of cognitive overload among older drivers based on HR response to the on-road driving task. The results provide preliminary evidence that mild age-related cognitive impairment may not pose a motor vehicle crash hazard for the wider older driver population. To maintain safe mobility of the aging population, further research into the specific crash risk factors in the older driver population is warranted.

  2. Bluetooth-based sensor networks for remotely monitoring the physiological signals of a patient.

    PubMed

    Zhang, Ying; Xiao, Hannan

    2009-11-01

    Integrating intelligent medical microsensors into a wireless communication network makes it possible to remotely collect physiological signals of a patient, release the patient from being tethered to monitoring medical instrumentations, and facilitate the patient's early hospital discharge. This can further improve life quality by providing continuous observation without the need of disrupting the patient's normal life, thus reducing the risk of infection significantly, and decreasing the cost of the hospital and the patient. This paper discusses the implementation issues, and describes the overall system architecture of our developed Bluetooth sensor network for patient monitoring and the corresponding heart activity sensors. It also presents our approach to developing the intelligent physiological sensor nodes involving integration of Bluetooth radio technology, hardware and software organization, and our solutions for onboard signal processing.

  3. Space Biosensor Systems: Implications for Technology Transfer

    NASA Technical Reports Server (NTRS)

    Hines, J. W.; Somps, C. J.; Madou, M.; Imprescia, Clifford C. (Technical Monitor)

    1997-01-01

    To meet the need for continuous, automated monitoring of animal subjects, including; humans, during space flight, NASA is developing advanced physiologic sensor and biotelemetry system technologies. The ability to continuously track basic physiological parameters, such as heart rate, blood pH, and body temperature, in untethered subjects in space is a challenging task. At NASA's Ames Research Center, where a key focus is gravitational biology research, engineers have teamed with life scientists to develop wireless sensor systems for automated physiologic monitoring of animal models as small as the rat. This technology is also being adapted, in collaboration with medical professionals, to meet human clinical monitoring needs both in space and on the ground. Thus, these advanced monitoring technologies have important dual-use functions; they meet space flight data collection requirements and constraints, while concurrently addressing a number of monitoring and data acquisition challenges on the ground in areas of clinical monitoring and biomedical research. Additional applications for these and related technologies are being sought and additional partnerships established that enhance development efforts, reduce costs and facilitate technology infusion between the public and private sectors. This paper describes technology transfer and co-development projects that have evolved out of NASA's miniaturized, implantable chemical sensor development efforts.

  4. Validation of Contact-Free Sleep Monitoring Device with Comparison to Polysomnography.

    PubMed

    Tal, Asher; Shinar, Zvika; Shaki, David; Codish, Shlomi; Goldbart, Aviv

    2017-03-15

    To validate a contact-free system designed to achieve maximal comfort during long-term sleep monitoring, together with high monitoring accuracy. We used a contact-free monitoring system (EarlySense, Ltd., Israel), comprising an under-the-mattress piezoelectric sensor and a smartphone application, to collect vital signs and analyze sleep. Heart rate (HR), respiratory rate (RR), body movement, and calculated sleep-related parameters from the EarlySense (ES) sensor were compared to data simultaneously generated by the gold standard, polysomnography (PSG). Subjects in the sleep laboratory underwent overnight technician-attended full PSG, whereas subjects at home were recorded for 1 to 3 nights with portable partial PSG devices. Data were compared epoch by epoch. A total of 63 subjects (85 nights) were recorded under a variety of sleep conditions. Compared to PSG, the contact-free system showed similar values for average total sleep time (TST), % wake, % rapid eye movement, and % non-rapid eye movement sleep, with 96.1% and 93.3% accuracy of continuous measurement of HR and RR, respectively. We found a linear correlation between TST measured by the sensor and TST determined by PSG, with a coefficient of 0.98 (R = 0.87). Epoch-by-epoch comparison with PSG in the sleep laboratory setting revealed that the system showed sleep detection sensitivity, specificity, and accuracy of 92.5%, 80.4%, and 90.5%, respectively. TST estimates with the contact-free sleep monitoring system were closely correlated with the gold-standard reference. This system shows good sleep staging capability with improved performance over accelerometer-based apps, and collects additional physiological information on heart rate and respiratory rate. © 2017 American Academy of Sleep Medicine

  5. How consumer physical activity monitors could transform human physiology research.

    PubMed

    Wright, Stephen P; Hall Brown, Tyish S; Collier, Scott R; Sandberg, Kathryn

    2017-03-01

    A sedentary lifestyle and lack of physical activity are well-established risk factors for chronic disease and adverse health outcomes. Thus, there is enormous interest in measuring physical activity in biomedical research. Many consumer physical activity monitors, including Basis Health Tracker, BodyMedia Fit, DirectLife, Fitbit Flex, Fitbit One, Fitbit Zip, Garmin Vivofit, Jawbone UP, MisFit Shine, Nike FuelBand, Polar Loop, Withings Pulse O 2 , and others have accuracies similar to that of research-grade physical activity monitors for measuring steps. This review focuses on the unprecedented opportunities that consumer physical activity monitors offer for human physiology and pathophysiology research because of their ability to measure activity continuously under real-life conditions and because they are already widely used by consumers. We examine current and potential uses of consumer physical activity monitors as a measuring or monitoring device, or as an intervention in strategies to change behavior and predict health outcomes. The accuracy, reliability, reproducibility, and validity of consumer physical activity monitors are reviewed, as are limitations and challenges associated with using these devices in research. Other topics covered include how smartphone apps and platforms, such as the Apple ResearchKit, can be used in conjunction with consumer physical activity monitors for research. Lastly, the future of consumer physical activity monitors and related technology is considered: pattern recognition, integration of sleep monitors, and other biosensors in combination with new forms of information processing. Copyright © 2017 the American Physiological Society.

  6. 21 CFR 868.2377 - Apnea monitor.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... breath. The apnea monitor also includes indirect methods of apnea detection such as monitoring of heart rate and other physiological parameters linked to the presence or absence of adequate respiration. (b...

  7. 21 CFR 868.2377 - Apnea monitor.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... breath. The apnea monitor also includes indirect methods of apnea detection such as monitoring of heart rate and other physiological parameters linked to the presence or absence of adequate respiration. (b...

  8. 21 CFR 868.2377 - Apnea monitor.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... breath. The apnea monitor also includes indirect methods of apnea detection such as monitoring of heart rate and other physiological parameters linked to the presence or absence of adequate respiration. (b...

  9. 21 CFR 868.2377 - Apnea monitor.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... breath. The apnea monitor also includes indirect methods of apnea detection such as monitoring of heart rate and other physiological parameters linked to the presence or absence of adequate respiration. (b...

  10. 21 CFR 868.2377 - Apnea monitor.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... breath. The apnea monitor also includes indirect methods of apnea detection such as monitoring of heart rate and other physiological parameters linked to the presence or absence of adequate respiration. (b...

  11. Glucose Sensing for Diabetes Monitoring: Recent Developments

    PubMed Central

    Bruen, Danielle; Delaney, Colm; Florea, Larisa

    2017-01-01

    This review highlights recent advances towards non-invasive and continuous glucose monitoring devices, with a particular focus placed on monitoring glucose concentrations in alternative physiological fluids to blood. PMID:28805693

  12. Validity and Reliability of an on-Court Fitness Test for Assessing and Monitoring Aerobic Fitness in Squash.

    PubMed

    James, Carl Alexander; Vallejo, Florencio Tenllado; Kantebeen, Melvin; Farra, Saro

    2018-02-14

    Current on-court assessments of aerobic fitness in squash are not designed to yield a wealth of physiological data. Moreover, tests may require complex computer equipment or involve simulated racket strokes, which are difficult to standardize at high intensities. This study investigated the validity and reliability of a squash-specific fitness test which can yield both a standalone performance score, as well as pertinent physiological markers such as V[Combining Dot Above]O2max, the lactate turnpoint and oxygen cost, in a sport-specific environment. Eight national squash players completed three tests in a counter-balanced order; an incremental laboratory treadmill test (LAB) and two on-court fitness tests (ST) that involved repeated shuttle runs at increasing speeds. V[Combining Dot Above]O2max during ST was agreeable with LAB (Typical error [TE]=3.3 mL.kg.min, r=0.79). The mean bias between LAB and ST was 2.5 mL.kg.min. There were no differences in maximum heart rate, post exercise blood lactate concentration or end of test RPE between LAB and ST (p>0.05). The ST was highly reliable, with 74 (10) laps completed in ST1 and 75 (12) laps in ST2 (mean bias=1 lap, TE=3 laps, r=0.97). Physiological markers were also reliable, including V[Combining Dot Above]O2max, (TE=1.5 mL.kg.min, r=0.95), the lap number at 4 mMol (TE=4 laps, r=0.77) and average VO2 across the first 4 stages (TE=0.94 mL.kg.min, r=0.95). We observed good agreement between LAB and ST for assessing V[Combining Dot Above]O2max and between both on-court trials for assessing test performance and selected physiological markers. Consequently, we recommend this test for monitoring training adaptations and prescribing individualized training in elite squash players.

  13. Comparing observed and predicted mortality among ICUs using different prognostic systems: why do performance assessments differ?

    PubMed

    Kramer, Andrew A; Higgins, Thomas L; Zimmerman, Jack E

    2015-02-01

    To compare ICU performance using standardized mortality ratios generated by the Acute Physiology and Chronic Health Evaluation IVa and a National Quality Forum-endorsed methodology and examine potential reasons for model-based standardized mortality ratio differences. Retrospective analysis of day 1 hospital mortality predictions at the ICU level using Acute Physiology and Chronic Health Evaluation IVa and National Quality Forum models on the same patient cohort. Forty-seven ICUs at 36 U.S. hospitals from January 2008 to May 2013. Eighty-nine thousand three hundred fifty-three consecutive unselected ICU admissions. None. We assessed standardized mortality ratios for each ICU using data for patients eligible for Acute Physiology and Chronic Health Evaluation IVa and National Quality Forum predictions in order to compare unit-level model performance, differences in ICU rankings, and how case-mix adjustment might explain standardized mortality ratio differences. Hospital mortality was 11.5%. Overall standardized mortality ratio was 0.89 using Acute Physiology and Chronic Health Evaluation IVa and 1.07 using National Quality Forum, the latter having a widely dispersed and multimodal standardized mortality ratio distribution. Model exclusion criteria eliminated mortality predictions for 10.6% of patients for Acute Physiology and Chronic Health Evaluation IVa and 27.9% for National Quality Forum. The two models agreed on the significance and direction of standardized mortality ratio only 45% of the time. Four ICUs had standardized mortality ratios significantly less than 1.0 using Acute Physiology and Chronic Health Evaluation IVa, but significantly greater than 1.0 using National Quality Forum. Two ICUs had standardized mortality ratios exceeding 1.75 using National Quality Forum, but nonsignificant performance using Acute Physiology and Chronic Health Evaluation IVa. Stratification by patient and institutional characteristics indicated that units caring for more severely ill patients and those with a higher percentage of patients on mechanical ventilation had the most discordant standardized mortality ratios between the two predictive models. Acute Physiology and Chronic Health Evaluation IVa and National Quality Forum models yield different ICU performance assessments due to differences in case-mix adjustment. Given the growing role of outcomes in driving prospective payment patient referral and public reporting, performance should be assessed by models with fewer exclusions, superior accuracy, and better case-mix adjustment.

  14. Vital Recorder-a free research tool for automatic recording of high-resolution time-synchronised physiological data from multiple anaesthesia devices.

    PubMed

    Lee, Hyung-Chul; Jung, Chul-Woo

    2018-01-24

    The current anaesthesia information management system (AIMS) has limited capability for the acquisition of high-quality vital signs data. We have developed a Vital Recorder program to overcome the disadvantages of AIMS and to support research. Physiological data of surgical patients were collected from 10 operating rooms using the Vital Recorder. The basic equipment used were a patient monitor, the anaesthesia machine, and the bispectral index (BIS) monitor. Infusion pumps, cardiac output monitors, regional oximeter, and rapid infusion device were added as required. The automatic recording option was used exclusively and the status of recording was frequently checked through web monitoring. Automatic recording was successful in 98.5% (4,272/4,335) cases during eight months of operation. The total recorded time was 13,489 h (3.2 ± 1.9 h/case). The Vital Recorder's automatic recording and remote monitoring capabilities enabled us to record physiological big data with minimal effort. The Vital Recorder also provided time-synchronised data captured from a variety of devices to facilitate an integrated analysis of vital signs data. The free distribution of the Vital Recorder is expected to improve data access for researchers attempting physiological data studies and to eliminate inequalities in research opportunities due to differences in data collection capabilities.

  15. A Wireless Physiological Signal Monitoring System with Integrated Bluetooth and WiFi Technologies.

    PubMed

    Yu, Sung-Nien; Cheng, Jen-Chieh

    2005-01-01

    This paper proposes a wireless patient monitoring system which integrates Bluetooth and WiFi wireless technologies. A wireless portable multi-parameter device was designated to acquire physiological signals and transmit them to a local server via Bluetooth wireless technology. Four kinds of monitor units were designed to communicate via the WiFi wireless technology, including a local monitor unit, a control center, mobile devices (personal digital assistant; PDA), and a web page. The use of various monitor units is intending to meet different medical requirements for different medical personnel. This system was demonstrated to promote the mobility and flexibility for both the patients and the medical personnel, which further improves the quality of health care.

  16. Using pupil size and heart rate to infer affective states during behavioral neurophysiology and neuropsychology experiments

    PubMed Central

    Mitz, Andrew R.; Chacko, Ravi V.; Putnam, Philip T.; Rudebeck, Peter H.; Murray, Elisabeth A.

    2017-01-01

    Background Nonhuman primates (NHPs) are a valuable research model because of their behavioral, physiological and neuroanatomical similarities to humans. In the absence of language, autonomic activity can provide crucial information about cognitive and affective states during single-unit recording, inactivation and lesion studies. Methods standardized for use in humans are not easily adapted to NHPs and detailed guidance has been lacking. New Method We provide guidance for monitoring heart rate and pupil size in the behavioral neurophysiology setting by addressing the methodological issues, pitfalls and solutions for NHP studies. The methods are based on comparative physiology to establish a rationale for each solution. We include examples from both electrophysiological and lesion studies. Results Single-unit recording, pupil responses and heart rate changes represent a range of decreasing temporal resolution, a characteristic that impacts experimental design and analysis. We demonstrate the unexpected result that autonomic measures acquired before and after amygdala lesions are comparable despite disruption of normal autonomic function. Comparison with Existing Methods Species and study design differences can render standard techniques used in human studies inappropriate for NHP studies. We show how to manage data from small groups typical of NHP studies, data from the short behavioral trials typical of neurophysiological studies, issues associated with longitudinal studies, and differences in anatomy and physiology. Conclusions Autonomic measurement to infer cognitive and affective states in NHP is neither off-the-shelf nor onerous. Familiarity with the issues and solutions will broaden the use of autonomic signals in NHP single unit and lesion studies. PMID:28089759

  17. Comparison of estimated core body temperature measured with the BioHarness and rectal temperature under several heat stress conditions.

    PubMed

    Seo, Yongsuk; DiLeo, Travis; Powell, Jeffrey B; Kim, Jung-Hyun; Roberge, Raymond J; Coca, Aitor

    2016-08-01

    Monitoring and measuring core body temperature is important to prevent or minimize physiological strain and cognitive dysfunction for workers such as first responders (e.g., firefighters) and military personnel. The purpose of this study is to compare estimated core body temperature (Tco-est), determined by heart rate (HR) data from a wearable chest strap physiology monitor, to standard rectal thermometry (Tre) under different conditions.  Tco-est and Tre measurements were obtained in thermoneutral and heat stress conditions (high temperature and relative humidity) during four different experiments including treadmill exercise, cycling exercise, passive heat stress, and treadmill exercise while wearing personal protective equipment (PPE).  Overall, the mean Tco-est did not differ significantly from Tre across the four conditions. During exercise at low-moderate work rates under heat stress conditions, Tco-est was consistently higher than Tre at all-time points. Tco-est underestimated temperature compared to Tre at rest in heat stress conditions and at a low work rate under heat stress while wearing PPE. The mean differences between the two measurements ranged from -0.1 ± 0.4 to 0.3 ± 0.4°C and Tco-est correlated well with HR (r = 0.795 - 0.849) and mean body temperature (r = 0.637 - 0.861).  These results indicate that, the comparison of Tco-est to Tre may result in over- or underestimation which could possibly lead to heat-related illness during monitoring in certain conditions. Modifications to the current algorithm should be considered to address such issues.

  18. 40 CFR 141.601 - Standard monitoring.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Standard monitoring. 141.601 Section... Standard monitoring. (a) Standard monitoring plan. Your standard monitoring plan must comply with paragraphs (a)(1) through (a)(4) of this section. You must prepare and submit your standard monitoring plan...

  19. Method for Visually Integrating Multiple Data Acquisition Technologies for Real Time and Retrospective Analysis

    NASA Technical Reports Server (NTRS)

    Bogart, Edward H. (Inventor); Pope, Alan T. (Inventor)

    2000-01-01

    A system for display on a single video display terminal of multiple physiological measurements is provided. A subject is monitored by a plurality of instruments which feed data to a computer programmed to receive data, calculate data products such as index of engagement and heart rate, and display the data in a graphical format simultaneously on a single video display terminal. In addition live video representing the view of the subject and the experimental setup may also be integrated into the single data display. The display may be recorded on a standard video tape recorder for retrospective analysis.

  20. Understanding fetal physiology and second line monitoring during labor.

    PubMed

    Garabedian, C; De Jonckheere, J; Butruille, L; Deruelle, P; Storme, L; Houfflin-Debarge, V

    2017-02-01

    Cardiotocography (CTG) is a technique used to monitor intrapartum fetal condition and is one of the most common obstetric procedures. Second line methods of fetal monitoring have been developed in an attempt to reduce unnecessary interventions due to continuous cardiotocography and to better identify fetuses at risk of intrapartum asphyxia. The acid-base balance of the fetus is evaluated by fetal blood scalp samples, the modification of the myocardial oxygenation by the fetal ECG ST-segment analysis (STAN) and the autonomic nervous system by the power spectral analysis of the fetal heart variability. To correctly interpret the features observed on CTG traces or second line methods, it seems important to understand normal physiology during labor and the compensatory mechanisms of the fetus in case of hypoxemia. Therefore, the aim of this review is first to describe fetal physiology during labor and then to explain the modification of the second line monitoring during labor. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  1. Seasonal differences in the physiology of Carcinus maenas (Crustacea: Decapoda) from estuaries with varying levels of anthropogenic contamination

    NASA Astrophysics Data System (ADS)

    Dissanayake, Awantha; Galloway, Tamara S.; Jones, Malcolm B.

    2011-07-01

    This study reports the seasonal variability in aspects of the physiology of the shore crab Carcinus maenas from three estuaries in South-west England, each with varying anthropogenic inputs: Avon Estuary ('relatively low' impact), Yealm Estuary ('intermediate' impact) and Plym Estuary ('relatively high' impact). Crabs collected over 12 months from the Avon had a significantly 'lower' physiological condition in winter and spring compared to summer and autumn; in particular, haemocyte phagocytic capability (a general indicator of immune function) was significantly higher in winter and spring compared to summer and autumn, and total haemolymph antioxidant status (an indicator of oxidative stress) was significantly lower in winter compared to the remainder of the year. Potentially, shore crabs may be more susceptible to the effects of contaminant exposure, such as increased immunotoxicity (thus, reduction of immune function) and/or oxyradicals (or reactive oxygen species) exposure) especially in seasons of increased susceptibility i.e. summer/autumn (lower phagocytic capability) and winter (lowest antioxidant function). As the Avon was taken to represent the 'reference' site, this pattern is considered to reflect the 'normal' seasonal variability in shore crab physiology. Shore crab physiological condition from the 'relatively high' impact estuary (Plym) revealed increased cellular viability and antioxidant status in autumn and winter compared with that of the 'standard' pattern (Avon) However, crabs from the intermediate impact estuary (Yealm) only demonstrated significant physiological differences in summer as shown by a lower cellular viability. All crabs had been exposed to PAHs (confirmed by the presence of PAH metabolites in their urine) which may account for the observed differences in shore crab physiology. In conclusion, to aid understanding of the potential contaminant impacts on biota it is imperative that the 'normal' seasonal variability of physiological condition be established. Biological effects-based monitoring studies should therefore be employed seasonally to potentially highlight 'windows of sensitivity' to contaminant impact.

  2. Wireless body sensor networks for health-monitoring applications.

    PubMed

    Hao, Yang; Foster, Robert

    2008-11-01

    Current wireless technologies, such as wireless body area networks and wireless personal area networks, provide promising applications in medical monitoring systems to measure specified physiological data and also provide location-based information, if required. With the increasing sophistication of wearable and implantable medical devices and their integration with wireless sensors, an ever-expanding range of therapeutic and diagnostic applications is being pursued by research and commercial organizations. This paper aims to provide a comprehensive review of recent developments in wireless sensor technology for monitoring behaviour related to human physiological responses. It presents background information on the use of wireless technology and sensors to develop a wireless physiological measurement system. A generic miniature platform and other available technologies for wireless sensors have been studied in terms of hardware and software structural requirements for a low-cost, low-power, non-invasive and unobtrusive system.

  3. Monitoring Detrusor Oxygenation and Hemodynamics Noninvasively during Dysfunctional Voiding

    PubMed Central

    Macnab, Andrew J.; Stothers, Lynn S.; Shadgan, Babak

    2012-01-01

    The current literature indicates that lower urinary tract symptoms (LUTSs) related to benign prostatic hyperplasia (BPH) have a heterogeneous pathophysiology. Pressure flow studies (UDSs) remain the gold standard evaluation methodology for such patients. However, as the function of the detrusor muscle depends on its vasculature and perfusion, the underlying causes of LUTS likely include abnormalities of detrusor oxygenation and hemodynamics, and available treatment options include agents thought to act on the detrusor smooth muscle and/or vasculature. Hence, near infrared spectroscopy (NIRS), an established optical methodology for monitoring changes in tissue oxygenation and hemodynamics, has relevance as a means of expanding knowledge related to the pathophysiology of BPH and potential treatment options. This methodological report describes how to conduct simultaneous NIRS monitoring of detrusor oxygenation and hemodynamics during UDS, outlines the clinical implications and practical applications of NIRS, explains the principles of physiologic interpretation of NIRS voiding data, and proposes an exploratory hypothesis that the pathophysiological causes underlying LUTS include detrusor dysfunction due to an abnormal hemodynamic response or the onset of oxygen debt during voiding. PMID:23019422

  4. Ambient intelligence for monitoring and research in clinical neurophysiology and medicine: the MIMERICA* project and prototype.

    PubMed

    Pignolo, L; Riganello, F; Dolce, G; Sannita, W G

    2013-04-01

    Ambient Intelligence (AmI) provides extended but unobtrusive sensing and computing devices and ubiquitous networking for human/environment interaction. It is a new paradigm in information technology compliant with the international Integrating Healthcare Enterprise board (IHE) and eHealth HL7 technological standards in the functional integration of biomedical domotics and informatics in hospital and home care. AmI allows real-time automatic recording of biological/medical information and environmental data. It is extensively applicable to patient monitoring, medicine and neuroscience research, which require large biomedical data sets; for example, in the study of spontaneous or condition-dependent variability or chronobiology. In this respect, AML is equivalent to a traditional laboratory for data collection and processing, with minimal dedicated equipment, staff, and costs; it benefits from the integration of artificial intelligence technology with traditional/innovative sensors to monitor clinical or functional parameters. A prototype AmI platform (MIMERICA*) has been implemented and is operated in a semi-intensive unit for the vegetative and minimally conscious states, to investigate the spontaneous or environment-related fluctuations of physiological parameters in these conditions.

  5. Coupling gene-based and classic veterinary diagnostics improves interpretation of health and immune function in the Agassiz’s desert tortoise (Gopherus agassizii)

    USGS Publications Warehouse

    Drake, Karla K.; Bowen, Lizabeth; Lewison, Rebecca L.; Esque, Todd C.; Nussear, Kenneth E.; Braun, Josephine; Waters, Shannon C.; Miles, A. Keith

    2017-01-01

    The analysis of blood constituents is a widely used tool to aid in monitoring of animal health and disease. However, classic blood diagnostics (i.e. hematologic and plasma biochemical values) often do not provide sufficient information to determine the state of an animal’s health. Field studies on wild tortoises and other reptiles have had limited success in drawing significant inferences between blood diagnostics and physiological and immunological condition. However, recent research using gene transcription profiling in the threatened Mojave desert tortoise (Gopherus agassizii) has proved useful in identifying immune or physiologic responses and overall health. To improve our understanding of health and immune function in tortoises, we evaluated both standard blood diagnostic (body condition, hematologic, plasma biochemistry values, trace elements, plasma proteins, vitamin A levels) and gene transcription profiles in 21 adult tortoises (11 clinically abnormal; 10 clinically normal) from Clark County, NV, USA. Necropsy and histology evaluations from clinically abnormal tortoises revealed multiple physiological complications, with moderate to severe rhinitis or pneumonia being the primary cause of morbidity in all but one of the examined animals. Clinically abnormal tortoises had increased transcription for four genes (SOD, MyD88, CL and Lep), increased lymphocyte production, biochemical enzymes and organics, trace elements of copper, and decreased numbers of leukocytes. We found significant positive correlations between increased transcription for SOD and increased trace elements for copper, as well as genes MyD88 and Lep with increased inflammation and microbial insults. Improved methods for health assessments are an important element of monitoring tortoise population recovery and can support the development of more robust diagnostic measures for ill animals, or individuals directly impacted by disturbance.

  6. Coupling gene-based and classic veterinary diagnostics improves interpretation of health and immune function in the Agassiz’s desert tortoise (Gopherus agassizii)

    PubMed Central

    Bowen, Lizabeth; Lewison, Rebecca L.; Esque, Todd C.; Nussear, Kenneth E.; Braun, Josephine; Waters, Shannon C.; Miles, A. Keith

    2017-01-01

    Abstract The analysis of blood constituents is a widely used tool to aid in monitoring of animal health and disease. However, classic blood diagnostics (i.e. hematologic and plasma biochemical values) often do not provide sufficient information to determine the state of an animal’s health. Field studies on wild tortoises and other reptiles have had limited success in drawing significant inferences between blood diagnostics and physiological and immunological condition. However, recent research using gene transcription profiling in the threatened Mojave desert tortoise (Gopherus agassizii) has proved useful in identifying immune or physiologic responses and overall health. To improve our understanding of health and immune function in tortoises, we evaluated both standard blood diagnostic (body condition, hematologic, plasma biochemistry values, trace elements, plasma proteins, vitamin A levels) and gene transcription profiles in 21 adult tortoises (11 clinically abnormal; 10 clinically normal) from Clark County, NV, USA. Necropsy and histology evaluations from clinically abnormal tortoises revealed multiple physiological complications, with moderate to severe rhinitis or pneumonia being the primary cause of morbidity in all but one of the examined animals. Clinically abnormal tortoises had increased transcription for four genes (SOD, MyD88, CL and Lep), increased lymphocyte production, biochemical enzymes and organics, trace elements of copper, and decreased numbers of leukocytes. We found significant positive correlations between increased transcription for SOD and increased trace elements for copper, as well as genes MyD88 and Lep with increased inflammation and microbial insults. Improved methods for health assessments are an important element of monitoring tortoise population recovery and can support the development of more robust diagnostic measures for ill animals, or individuals directly impacted by disturbance. PMID:28835840

  7. Coupling gene-based and classic veterinary diagnostics improves interpretation of health and immune function in the Agassiz's desert tortoise (Gopherus agassizii).

    PubMed

    Drake, K Kristina; Bowen, Lizabeth; Lewison, Rebecca L; Esque, Todd C; Nussear, Kenneth E; Braun, Josephine; Waters, Shannon C; Miles, A Keith

    2017-01-01

    The analysis of blood constituents is a widely used tool to aid in monitoring of animal health and disease. However, classic blood diagnostics (i.e. hematologic and plasma biochemical values) often do not provide sufficient information to determine the state of an animal's health. Field studies on wild tortoises and other reptiles have had limited success in drawing significant inferences between blood diagnostics and physiological and immunological condition. However, recent research using gene transcription profiling in the threatened Mojave desert tortoise ( Gopherus agassizii ) has proved useful in identifying immune or physiologic responses and overall health. To improve our understanding of health and immune function in tortoises, we evaluated both standard blood diagnostic (body condition, hematologic, plasma biochemistry values, trace elements, plasma proteins, vitamin A levels) and gene transcription profiles in 21 adult tortoises (11 clinically abnormal; 10 clinically normal) from Clark County, NV, USA. Necropsy and histology evaluations from clinically abnormal tortoises revealed multiple physiological complications, with moderate to severe rhinitis or pneumonia being the primary cause of morbidity in all but one of the examined animals. Clinically abnormal tortoises had increased transcription for four genes (SOD, MyD88, CL and Lep), increased lymphocyte production, biochemical enzymes and organics, trace elements of copper, and decreased numbers of leukocytes. We found significant positive correlations between increased transcription for SOD and increased trace elements for copper, as well as genes MyD88 and Lep with increased inflammation and microbial insults. Improved methods for health assessments are an important element of monitoring tortoise population recovery and can support the development of more robust diagnostic measures for ill animals, or individuals directly impacted by disturbance.

  8. Skylab hardware report operational bioinstrumentation system

    NASA Technical Reports Server (NTRS)

    Luczkowski, S.

    1977-01-01

    The Skylab Operational Bioinstrumentation System is a personal, individually adjustable biomedical system designed to monitor the basic physiological functions of each suited crewman during specified periods of a manned space mission. The basic physiological functions of this system include electrocardiogram, respiration by impedance pneumogram, body temperature, cardiotachometer, and subject identification. The Operational Bioinstrumentation System was scheduled to monitor each crewman during launch, extravehicular activities, suited intravehicular experiments, and undocking and return.

  9. Signatures of subacute potentially catastrophic illness in the intensive care unit: model development and validation

    PubMed Central

    Moss, Travis J.; Lake, Douglas E.; Forrest Calland, J; Enfield, Kyle B; Delos, John B.; Fairchild, Karen D.; Randall Moorman, J.

    2016-01-01

    Objective Patients in intensive care units are susceptible to subacute, potentially catastrophic illnesses such as respiratory failure, sepsis, and hemorrhage that present as severe derangements of vital signs. More subtle physiologic signatures may be present before clinical deterioration, when treatment might be more effective. We performed multivariate statistical analyses of bedside physiologic monitoring data to identify such early, subclinical signatures of incipient life-threatening illness. Design We report a study of model development and validation of a retrospective observational cohort using resampling (TRIPOD Type 1b internal validation), and a study of model validation using separate data (Type 2b internal/external validation). Setting University of Virginia Health System (Charlottesville), a tertiary-care, academic medical center. Patients Critically ill patients consecutively admitted between January 2009 and June 2015 to either the neonatal, surgical/trauma/burn, or medical intensive care units with available physiologic monitoring data. Interventions None. Measurements and Main Results We analyzed 146 patient-years of vital sign and electrocardiography waveform time series from the bedside monitors of 9,232 ICU admissions. Calculations from 30-minute windows of the physiologic monitoring data were made every 15 minutes. Clinicians identified 1,206 episodes of respiratory failure leading to urgent, unplanned intubation, sepsis, or hemorrhage leading to multi-unit transfusions from systematic, individual chart reviews. Multivariate models to predict events up to 24 hours prior had internally-validated C-statistics of 0.61 to 0.88. In adults, physiologic signatures of respiratory failure and hemorrhage were distinct from each other but externally consistent across ICUs. Sepsis, on the other hand, demonstrated less distinct and inconsistent signatures. Physiologic signatures of all neonatal illnesses were similar. Conclusions Subacute, potentially catastrophic illnesses in 3 diverse ICU populations have physiologic signatures that are detectable in the hours preceding clinical detection and intervention. Detection of such signatures can draw attention to patients at highest risk, potentially enabling earlier intervention and better outcomes. PMID:27452809

  10. Signatures of Subacute Potentially Catastrophic Illness in the ICU: Model Development and Validation.

    PubMed

    Moss, Travis J; Lake, Douglas E; Calland, J Forrest; Enfield, Kyle B; Delos, John B; Fairchild, Karen D; Moorman, J Randall

    2016-09-01

    Patients in ICUs are susceptible to subacute potentially catastrophic illnesses such as respiratory failure, sepsis, and hemorrhage that present as severe derangements of vital signs. More subtle physiologic signatures may be present before clinical deterioration, when treatment might be more effective. We performed multivariate statistical analyses of bedside physiologic monitoring data to identify such early subclinical signatures of incipient life-threatening illness. We report a study of model development and validation of a retrospective observational cohort using resampling (Transparent Reporting of a multivariable prediction model for Individual Prognosis Or Diagnosis type 1b internal validation) and a study of model validation using separate data (type 2b internal/external validation). University of Virginia Health System (Charlottesville), a tertiary-care, academic medical center. Critically ill patients consecutively admitted between January 2009 and June 2015 to either the neonatal, surgical/trauma/burn, or medical ICUs with available physiologic monitoring data. None. We analyzed 146 patient-years of vital sign and electrocardiography waveform time series from the bedside monitors of 9,232 ICU admissions. Calculations from 30-minute windows of the physiologic monitoring data were made every 15 minutes. Clinicians identified 1,206 episodes of respiratory failure leading to urgent unplanned intubation, sepsis, or hemorrhage leading to multi-unit transfusions from systematic individual chart reviews. Multivariate models to predict events up to 24 hours prior had internally validated C-statistics of 0.61-0.88. In adults, physiologic signatures of respiratory failure and hemorrhage were distinct from each other but externally consistent across ICUs. Sepsis, on the other hand, demonstrated less distinct and inconsistent signatures. Physiologic signatures of all neonatal illnesses were similar. Subacute potentially catastrophic illnesses in three diverse ICU populations have physiologic signatures that are detectable in the hours preceding clinical detection and intervention. Detection of such signatures can draw attention to patients at highest risk, potentially enabling earlier intervention and better outcomes.

  11. EEG monitoring of a free-swimming diver at a working depth of 15 meters.

    NASA Technical Reports Server (NTRS)

    Zweizig, J. R.; Adey, W. R.; Hanley, J.; Hahn, P. M.; Pilmanis, A. A.; Given, R. R.; Cockett, A. T. K.

    1972-01-01

    Feasibility has been shown for underwater transmission of physiological signals, using frequency modulation of carriers transmitted by return-current-density methods, as part of a personal biotelemetry system. In the prototype system, a standard IRIG subcarrier frequency (2300 Hz) was used. Power requirements, antenna design, and signal attenuation are compatible with free-ranging diving activity at distances up to 15 meters from the receiver. Extrapolation from this study and further developments are expected to substantially increase the range. Advantages of this system include subcarrier compatibility with standard IRIG demodulators using channels 1 through 10, the absence of highly specialized antenna requirements, and reasonable attenuation characteristics for transmission through the turbidity of typical seawater. Moreover, the system would not appear to be depth limited, and to be compatible with use of high-powered transponders of the same type for long-distance transmission, with or without further encoding.

  12. [Studies on the health standard for room temperature in cold regions].

    PubMed

    Meng, Z L

    1990-03-01

    The microclimate of 205 rooms of single storey houses in four new rural residential districts in coastal and inland Shandong was monitored and studied the blood circulation of the finger, skin temperature, sweating function and other physiological indexes among 2,401 peasants. We interrogated their personal sensation to cold and warmth. The count was done by the application of thermal equilibrium index (TEI), predicted 4-hour Sweat Rate (P4SR) and the uncomfortable index. The standard room temperature is recommended as follows. In rural area in winter the appropriate room temperature is 14-16 degrees C, the comfortable room temperature is 16-20 degrees C, the lowest room temperature must not be below 14 degrees C. In summer the appropriate room temperature is 25-28 degrees C, the comfortable room temperature is 26-27 degrees C, the highest temperature must not be above 28 degrees C.

  13. Physiological Strain in French Vineyard Workers Wearing Protective Equipment to Conduct Re-Entry Tasks in Humid Conditions.

    PubMed

    Grimbuhler, Sonia; Viel, Jean-François

    2018-06-19

    The proper use of personal protective equipment (PPE) plays an important role in reducing exposure to pesticides in vineyard farming activities, including re-entry tasks. However, discomfort from clothing systems may increase the physiological burden on workers. We compared the physiological burdens of vineyard workers wearing three different types of PPE during canopy management in field humid conditions while accounting for occupational, climatic, and geographical environments. The study was conducted in the Bordeaux vineyards of southern France during June 2012. A total of 42 workers from seven vineyards consented to field observations. The following PPE garments were randomly allocated: HF Estufa polyamide (Brisa®), Tyvek® Classic Plus, and Tychem® C Standard. Participant sociodemographic characteristics were collected using a structured questionnaire. Skin temperature and heart rate were monitored continuously using portable devices. Multivariate multilevel linear regression models were performed to account for the hierarchical structure of data. No significant difference was found for mean skin temperature during work. Regardless of the cardiac strain parameter considered, the Tyvek® Classic Plus garment produced the poorest results (P ≤ 0.03). Under the very humid conditions encountered during the field study, the thinness and breathability of the Tyvek® Classic Plus garment resulted in undergarment humidity, imposing additional physiological burden on vineyard workers. These results confirm that the idea of using generic coveralls in any farming activity is unsuitable. Compromises should be created between physiological costs and protection, depending on the agricultural task performed, the crop grown, and the environmental conditions encountered.

  14. A knowledge authoring tool for clinical decision support.

    PubMed

    Dunsmuir, Dustin; Daniels, Jeremy; Brouse, Christopher; Ford, Simon; Ansermino, J Mark

    2008-06-01

    Anesthesiologists in the operating room are unable to constantly monitor all data generated by physiological monitors. They are further distracted by clinical and educational tasks. An expert system would ideally provide assistance to the anesthesiologist in this data-rich environment. Clinical monitoring expert systems have not been widely adopted, as traditional methods of knowledge encoding require both expert medical and programming skills, making knowledge acquisition difficult. A software application was developed for use as a knowledge authoring tool for physiological monitoring. This application enables clinicians to create knowledge rules without the need of a knowledge engineer or programmer. These rules are designed to provide clinical diagnosis, explanations and treatment advice for optimal patient care to the clinician in real time. By intelligently combining data from physiological monitors and demographical data sources the expert system can use these rules to assist in monitoring the patient. The knowledge authoring process is simplified by limiting connective relationships between rules. The application is designed to allow open collaboration between communities of clinicians to build a library of rules for clinical use. This design provides clinicians with a system for parameter surveillance and expert advice with a transparent pathway of reasoning. A usability evaluation demonstrated that anesthesiologists can rapidly develop useful rules for use in a predefined clinical scenario.

  15. Non-invasive evaluation of physiological stress in an iconic Australian marsupial: the Koala (Phascolarctos cinereus).

    PubMed

    Narayan, Edward J; Webster, Koa; Nicolson, Vere; Mucci, Al; Hero, Jean-Marc

    2013-06-15

    Koalas (Phascolarctos cinereus) are the only extant representatives of Australia's unique marsupial family Phascolarctidae and were listed as nationally Vulnerable in 2012. Causes of mortality are diverse, although the disease chlamydiosis, dog attacks, collisions with cars, and loss of habitat represent the principal reasons for the continued species decline. Koala breeding facilities in Queensland and New South Wales, Australia have been established for conservation and tourism. Non-invasive monitoring of physiological stress is important for determining the sub-lethal effects of environmental stressors on the well-being, reproduction and survival of Koalas in Zoos and also in the wild. In this study, we developed a faecal cortisol metabolite (FCM) enzyme-immunoassay (EIA) for monitoring physiological stress in Koalas from two established Zoos in Australia and also within a free-living sub-population from Queensland. Biological validation of the FCM EIA was done using an adrenocorticotropic hormone (ACTH) challenge. We discovered excretory lag-times of FCM of 24 h in females (n=2) and 48 h in male (n=2) Koalas in response to the ACTH challenge. FCM levels showed an episodic and delayed peak response lasting up to 9 days post ACTH challenge. This finding should be taken into consideration when designing future experiments to study the impacts of short-term (acute) and chronic stressors on the Koalas. Laboratory validations were done using parallelism and recovery checks (extraction efficiency) of the cortisol standard against pooled Koala faecal extracts. Greater than 99% recovery of the cortisol standard was obtained as well as a parallel displacement curve against Koala faecal extracts. FCM levels of the captive Koalas (n=10 males and 13 females) significantly differed by sex, reproductive condition (lactating versus non-lactating Koalas) and the handling groups. Handled male Koalas had 200% higher FCM levels than their non-handled counterparts, while females were not affected by handling as long they were not undergoing lactation. There was no significant difference in FCM levels between the captive and wild Koalas (n=9 males and 7 females). Overall, these results provide foundation knowledge on non-invasive FCM analysis in this iconic Australian marsupial. Non-invasive stress endocrinology opens up opportunities for evaluating the sub-lethal physiological effects of management activities (including caging, translocation) on the nutritional status, reproductive behaviors and disease status of captive and managed in situ Koala populations. Copyright © 2013 Elsevier Inc. All rights reserved.

  16. Autonomic physiological data associated with simulator discomfort

    NASA Technical Reports Server (NTRS)

    Miller, James C.; Sharkey, Thomas J.; Graham, Glenna A.; Mccauley, Michael E.

    1993-01-01

    The development of a physiological monitoring capability for the Army's advanced helicopter simulator facility is reported. Additionally, preliminary physiological data is presented. Our objective was to demonstrate the sensitivity of physiological measures in this simulator to self-reported simulator sickness. The data suggested that heart period, hypergastria, and skin conductance level were more sensitive to simulator sickness than were vagal tone and normal electrogastric activity.

  17. Flight physiology training experiences and perspectives: survey of 117 pilots.

    PubMed

    Patrão, Luís; Zorro, Sara; Silva, Jorge; Castelo-Branco, Miguel; Ribeiro, João

    2013-06-01

    Human factors and awareness of flight physiology play a crucial role in flight safety. Even so, international legislation is vague relative to training requirements in hypoxia and altitude physiology. Based on a previously developed survey, an adapted questionnaire was formulated and released online for Portuguese pilots. Specific questions regarding the need for pilot attention monitoring systems were added to the original survey. There were 117 pilots, 2 of whom were women, who completed the survey. Most of the pilots had a light aviation license and flew in unpressurized cabins at a maximum ceiling of 10,000 ft (3048 m). The majority of the respondents never experienced hypoxic symptoms. In general, most of the individuals agreed with the importance of an introductory hypoxia course without altitude chamber training (ACT) for all pilot populations, and with a pilot monitoring system in order to increase flight safety. Generally, most of the pilots felt that hypoxia education and training for unpressurized aircraft is not extensive enough. However, almost all the respondents were willing to use a flight physiology monitoring system in order to improve flight safety.

  18. Incorporating Research Findings into Standards and Requirements for Space Medicine

    NASA Technical Reports Server (NTRS)

    Duncan, J. Michael

    2006-01-01

    The Vision for Exploration has been the catalyst for NASA to refocus its life sciences research. In the future, life sciences research funded by NASA will be focused on answering questions that directly impact setting physiological standards and developing effective countermeasures to the undesirable physiological and psychological effects of spaceflight for maintaining the health of the human system. This, in turn, will contribute to the success of exploration class missions. We will show how research will impact setting physiologic standards, such as exposure limits, outcome limits, and accepted performance ranges. We will give examples of how a physiologic standard can eventually be translated into an operational requirement, then a functional requirement, and eventually spaceflight hardware or procedures. This knowledge will be important to the space medicine community as well as to vehicle contractors who, for the first time, must now consider the human system in developing and constructing a vehicle that can achieve the goal of success.

  19. Intrinsic optical signal imaging of glucose-stimulated physiological responses in the insulin secreting INS-1 β-cell line

    NASA Astrophysics Data System (ADS)

    Li, Yi-Chao; Cui, Wan-Xing; Wang, Xu-Jing; Amthor, Franklin; Yao, Xin-Cheng

    2011-03-01

    Intrinsic optical signal (IOS) imaging has been established for noninvasive monitoring of stimulus-evoked physiological responses in the retina and other neural tissues. Recently, we extended the IOS imaging technology for functional evaluation of insulin secreting INS-1 cells. INS-1 cells provide a popular model for investigating β-cell dysfunction and diabetes. Our experiments indicate that IOS imaging allows simultaneous monitoring of glucose-stimulated physiological responses in multiple cells with high spatial (sub-cellular) and temporal (sub-second) resolution. Rapid image sequences reveal transient optical responses that have time courses comparable to glucose-evoked β-cell electrical activities.

  20. Hospital protocols for targeted glycemic control: Development, implementation, and models for cost justification.

    PubMed

    Magee, Michelle F

    2007-05-15

    Evolving elements of best practices for providing targeted glycemic control in the hospital setting, clinical performance measurement, basal-bolus plus correction-dose insulin regimens, components of standardized subcutaneous (s.c.) insulin order sets, and strategies for implementation and cost justification of glycemic control initiatives are discussed. Best practices for targeted glycemic control should address accurate documentation of hyperglycemia, initial patient assessment, management plan, target blood glucose range, blood glucose monitoring frequency, maintenance of glycemic control, criteria for glucose management consultations, and standardized insulin order sets and protocols. Establishing clinical performance measures, including desirable processes and outcomes, can help ensure the success of targeted hospital glycemic control initiatives. The basal-bolus plus correction-dose regimen for insulin administration will be used to mimic the normal physiologic pattern of endogenous insulin secretion. Standardized insulin order sets and protocols are being used to minimize the risk of error in insulin therapy. Components of standardized s.c. insulin order sets include specification of the hyperglycemia diagnosis, finger stick blood glucose monitoring frequency and timing, target blood glucose concentration range, cutoff values for excessively high or low blood glucose concentrations that warrant alerting the physician, basal and prandial or nutritional (i.e., bolus) insulin, correction doses, hypoglycemia treatment, and perioperative or procedural dosage adjustments. The endorsement of hospital administrators and key physician and nursing leaders is needed for glycemic control initiatives. Initiatives may be cost justified on the basis of the billings for clinical diabetes management services and/or the return- on-investment accrued to reductions in hospital length of stay, readmissions, and accurate documentation and coding of unrecognized or uncontrolled diabetes, and diabetes complications. Standardized insulin order sets and protocols may minimize risk of insulin errors. The endorsement of these protocols by administrators, physicians, nurses, and pharmacists is also needed for success.

  1. Validation of Contact-Free Sleep Monitoring Device with Comparison to Polysomnography

    PubMed Central

    Tal, Asher; Shinar, Zvika; Shaki, David; Codish, Shlomi; Goldbart, Aviv

    2017-01-01

    Study Objectives: To validate a contact-free system designed to achieve maximal comfort during long-term sleep monitoring, together with high monitoring accuracy. Methods: We used a contact-free monitoring system (EarlySense, Ltd., Israel), comprising an under-the-mattress piezoelectric sensor and a smartphone application, to collect vital signs and analyze sleep. Heart rate (HR), respiratory rate (RR), body movement, and calculated sleep-related parameters from the EarlySense (ES) sensor were compared to data simultaneously generated by the gold standard, polysomnography (PSG). Subjects in the sleep laboratory underwent overnight technician-attended full PSG, whereas subjects at home were recorded for 1 to 3 nights with portable partial PSG devices. Data were compared epoch by epoch. Results: A total of 63 subjects (85 nights) were recorded under a variety of sleep conditions. Compared to PSG, the contact-free system showed similar values for average total sleep time (TST), % wake, % rapid eye movement, and % non-rapid eye movement sleep, with 96.1% and 93.3% accuracy of continuous measurement of HR and RR, respectively. We found a linear correlation between TST measured by the sensor and TST determined by PSG, with a coefficient of 0.98 (R = 0.87). Epoch-by-epoch comparison with PSG in the sleep laboratory setting revealed that the system showed sleep detection sensitivity, specificity, and accuracy of 92.5%, 80.4%, and 90.5%, respectively. Conclusions: TST estimates with the contact-free sleep monitoring system were closely correlated with the gold-standard reference. This system shows good sleep staging capability with improved performance over accelerometer-based apps, and collects additional physiological information on heart rate and respiratory rate. Citation: Tal A, Shinar Z, Shaki D, Codish S, Goldbart A. Validation of contact-free sleep monitoring device with comparison to polysomnography. J Clin Sleep Med. 2017;13(3):517–522. PMID:27998378

  2. A Reliable and Non-destructive Method for Monitoring the Stromal pH in Isolated Chloroplasts Using a Fluorescent pH Probe.

    PubMed

    Su, Pai-Hsiang; Lai, Yen-Hsun

    2017-01-01

    The proton gradient established by the pH difference across a biological membrane is essential for many physiological processes, including ATP synthesis and ion and metabolite transport. Currently, ionophores are used to study proton gradients, and determine their importance to biological functions of interest. Because of the lack of an easy method for monitoring the proton gradient across the inner envelope membrane of chloroplasts (ΔpH env ), whether the concentration of ionophores used can effectively abolish the ΔpH env is not proven for most experiments. To overcome this hindrance, we tried to setup an easy method for real-time monitoring of the stromal pH in buffered, isolated chloroplasts by using fluorescent pH probes; using this method the ΔpH env can be calculated by subtracting the buffer pH from the measured stromal pH. When three fluorescent dyes, BCECF-AM [2',7'-bis-(2-carboxyethyl)-5-(and-6)-carboxyfluorescein acetoxymethyl ester], CFDA-SE [5(6)-Carboxyfluorescein diacetate succinimidyl ester] and SNARF-1 carboxylic acid acetate succinimidyl ester were incubated with isolated chloroplasts, BCECF-AM and CFDA-SE, but not the ester-formed SNARF-1 were taken up by chloroplasts and digested with esterase to release high levels of fluorescence. According to its relatively higher pKa value (6.98, near the physiological pH of the stroma), BCECF was chosen for further development. Due to shielding of the excitation and emission lights by chloroplast pigments, the ratiometric fluorescence of BCECF was highly dependent on the concentration of chloroplasts. By using a fixed concentration of chloroplasts, a highly correlated standard curve of pH to the BCECF ratiometric fluorescence with an r -square value of 0.98 was obtained, indicating the reliability of this method. Consistent with previous reports, the light-dependent formation of ΔpH env can be detected ranging from 0.15 to 0.33 pH units upon illumination. The concentration of the ionophore nigericin required to collapse the ΔpH env was then studied. The establishment of a non-destructive method of monitoring the stromal pH will be valuable for studying the roles of the ΔpH env in chloroplast physiology.

  3. Form Factor Evaluation of Open Body Area Network (OBAN) Physiological Status Monitoring (PSM) System Prototype Designs

    DTIC Science & Technology

    2018-05-11

    SYSTEM PROTOTYPE DESIGNS DISCLAIMERS The opinions or assertions contained herein are the private views of the author(s) and are not to be construed as...FORM FACTOR EVALUATION OF OPEN BODY AREA NETWORK (OBAN) PHYSIOLOGICAL STATUS MONITORING (PSM) SYSTEM PROTOTYPE DESIGNS William J...security; and is designed to function for 72 hours or more. The test described in this report assesses proposed form-factor designs . Feedback using

  4. Nonintrusive biological signal monitoring in a car to evaluate a driver's stress and health state.

    PubMed

    Baek, Hyun Jae; Lee, Haet Bit; Kim, Jung Soo; Choi, Jong Min; Kim, Ko Keun; Park, Kwang Suk

    2009-03-01

    Nonintrusive monitoring of a driver's physiological signals was introduced and evaluated in a car as a test of extending the concept of ubiquitous healthcare to vehicles. Electrocardiogram, photoplethysmogram, galvanic skin response, and respiration were measured in the ubiquitous healthcare car (U-car) using nonintrusively installed sensors on the steering wheel, driver's seat, and seat belt. Measured signals were transmitted to the embedded computer via Bluetooth(R) communication and processed. We collected and analyzed physiological signals during driving in order to estimate a driver's stress state while using this system. In order to compare the effect of stress on physical and mental conditions, two categories of stresses were defined. Experimental results show that a driver's physiological signals were measured with acceptable quality for analysis without interrupting driving, and they were changed meaningfully due to elicited stress. This nonintrusive monitoring can be used to evaluate a driver's state of health and stress.

  5. Effects of work-related sleep restriction on acute physiological and psychological stress responses and their interactions: A review among emergency service personnel.

    PubMed

    Wolkow, Alexander; Ferguson, Sally; Aisbett, Brad; Main, Luana

    2015-01-01

    Emergency work can expose personnel to sleep restriction. Inadequate amounts of sleep can negatively affect physiological and psychological stress responses. This review critiqued the emergency service literature (e.g., firefighting, police/law enforcement, defense forces, ambulance/paramedic personnel) that has investigated the effect of sleep restriction on hormonal, inflammatory and psychological responses. Furthermore, it investigated if a psycho-physiological approach can help contextualize the significance of such responses to assist emergency service agencies monitor the health of their personnel. The available literature suggests that sleep restriction across multiple work days can disrupt cytokine and cortisol levels, deteriorate mood and elicit simultaneous physiological and psychological responses. However, research concerning the interaction between such responses is limited and inconclusive. Therefore, it is unknown if a psycho-physiological relationship exists and as a result, it is currently not feasible for agencies to monitor sleep restriction related stress based on psycho- physiological interactions. Sleep restriction does however, appear to be a major stressor contributing to physiological and psychological responses and thus, warrants further investigation. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  6. Biomedical Monitoring By A Novel Noncontact Radio Frequency Technology Project

    NASA Technical Reports Server (NTRS)

    Oliva-Buisson, Yvette J. (Compiler)

    2014-01-01

    The area of Space Health and Medicine is one of the NASA's Space Technology Grand Challenges. Space is an extreme environment which is not conducive to human life. The extraterrestrial environment can result in the deconditioning of various human physiological systems and thus require easy to use physiological monitoring technologies in order to better monitor space crews for appropriate health management and successful space missions and space operations. Furthermore, the Space Technology Roadmap's Technology Area Breakdown Structure calls for improvements in research to support human health and performance (Technology Area 06). To address these needs, this project investigated a potential noncontact and noninvasive radio frequency-based technique of monitoring central hemodynamic function in human research subjects in response to orthostatic stress.

  7. Developing a Nationwide K-12 Outreach Model: Physiology Understanding (PhUn) Week 10 Years Later

    ERIC Educational Resources Information Center

    Stieben, Margaret; Halpin, Patricia A.; Matyas, Marsha Lakes

    2017-01-01

    Since 2005, nearly 600 Physiology Understanding Week (PhUn Week) events have taken place across the U.S., involving American Physiological Society (APS) members in K-12 outreach. The program seeks to build student understanding of physiology and physiology careers, assist teachers in recognizing physiology in their standards-based curriculum, and…

  8. Daily Physical Activity and Hot Flashes in the Study of Women's Health Across the Nation FLASHES Study

    PubMed Central

    Gibson, Carolyn; Matthews, Karen; Thurston, Rebecca

    2014-01-01

    Objective To examine the role of physical activity in menopausal hot flashes. Competing models conceptualize physical activity as a risk or protective factor for hot flashes. Few studies have examined this relationship prospectively using physiologic measures of hot flashes and physical activity. Design Over two 48 hour-periods, 51 participants wore a physiologic hot flash monitor and activity monitor, and reported their hot flashes in an electronic diary. Physiologic hot flashes, reported hot flashes and reported hot flashes without physiological corroboration were related to activity changes using hierarchical generalized linear modeling, adjusting for potential confounders. Setting Community. Patients Midlife women. Interventions None. Main Outcome Measures Physiologically-detected hot flashes and reported hot flashes with and without physiologic corroboration. Results Hot flash reports without physiologic corroboration were more likely after activity increases (OR 1.04, 95% CI: 1.00-1.10, p=.01), particularly among women with higher levels of depressive symptoms (interaction p=.02). No other types of hot flashes were related to physical activity. Conclusion Acute increases in physical activity were associated with increased reporting of hot flashes lacking physiologic corroboration, particularly among women with depressive symptoms. Clinicians should consider the role of symptom perception and reporting in relations between physical activity and hot flashes. PMID:24491454

  9. Micro-patterned graphene-based sensing skins for human physiological monitoring

    NASA Astrophysics Data System (ADS)

    Wang, Long; Loh, Kenneth J.; Chiang, Wei-Hung; Manna, Kausik

    2018-03-01

    Ultrathin, flexible, conformal, and skin-like electronic transducers are emerging as promising candidates for noninvasive and nonintrusive human health monitoring. In this work, a wearable sensing membrane is developed by patterning a graphene-based solution onto ultrathin medical tape, which can then be attached to the skin for monitoring human physiological parameters and physical activity. Here, the sensor is validated for monitoring finger bending/movements and for recognizing hand motion patterns, thereby demonstrating its future potential for evaluating athletic performance, physical therapy, and designing next-generation human-machine interfaces. Furthermore, this study also quantifies the sensor’s ability to monitor eye blinking and radial pulse in real-time, which can find broader applications for the healthcare sector. Overall, the printed graphene-based sensing skin is highly conformable, flexible, lightweight, nonintrusive, mechanically robust, and is characterized by high strain sensitivity.

  10. Defining the limits of physiological plasticity: how gene expression can assess and predict the consequences of ocean change

    PubMed Central

    Evans, Tyler G.; Hofmann, Gretchen E.

    2012-01-01

    Anthropogenic stressors, such as climate change, are driving fundamental shifts in the abiotic characteristics of marine ecosystems. As the environmental aspects of our world's oceans deviate from evolved norms, of major concern is whether extant marine species possess the capacity to cope with such rapid change. In what many scientists consider the post-genomic era, tools that exploit the availability of DNA sequence information are being increasingly recognized as relevant to questions surrounding ocean change and marine conservation. In this review, we highlight the application of high-throughput gene-expression profiling, primarily transcriptomics, to the field of marine conservation physiology. Through the use of case studies, we illustrate how gene expression can be used to standardize metrics of sub-lethal stress, track organism condition in natural environments and bypass phylogenetic barriers that hinder the application of other physiological techniques to conservation. When coupled with fine-scale monitoring of environmental variables, gene-expression profiling provides a powerful approach to conservation capable of informing diverse issues related to ocean change, from coral bleaching to the spread of invasive species. Integrating novel approaches capable of improving existing conservation strategies, including gene-expression profiling, will be critical to ensuring the ecological and economic health of the global ocean. PMID:22566679

  11. Bio-integrated electronics and sensor systems

    NASA Astrophysics Data System (ADS)

    Yeo, Woon-Hong; Webb, R. Chad; Lee, Woosik; Jung, Sungyoung; Rogers, John A.

    2013-05-01

    Skin-mounted epidermal electronics, a strategy for bio-integrated electronics, provide an avenue to non-invasive monitoring of clinically relevant physiological signals for healthcare applications. Current conventional systems consist of single-point sensors fastened to the skin with adhesives, and sometimes with conducting gels, which limits their use outside of clinical settings due to loss of adhesion and irritation to the user. In order to facilitate extended use of skin-mounted healthcare sensors without disrupting everyday life, we envision electronic monitoring systems that integrate seamlessly with the skin below the notice of the user. This manuscript reviews recent significant results towards our goal of wearable electronic sensor systems for long-term monitoring of physiological signals. Ultra-thin epidermal electronic systems (EES) are demonstrated for extended use on the skin, in a conformal manner, including during everyday bathing and sleeping activities. We describe the assessment of clinically relevant physiological parameters, such as electrocardiograms (ECG), electromyograms (EMG), electroencephalograms (EEG), temperature, mechanical strain and thermal conductivity, using examples of multifunctional EES devices. Additionally, we demonstrate capability for real life application of EES by monitoring the system functionality, which has no discernible change, during cyclic fatigue testing.

  12. Research on human physiological parameters intelligent clothing based on distributed Fiber Bragg Grating

    NASA Astrophysics Data System (ADS)

    Miao, Changyun; Shi, Boya; Li, Hongqiang

    2008-12-01

    A human physiological parameters intelligent clothing is researched with FBG sensor technology. In this paper, the principles and methods of measuring human physiological parameters including body temperature and heart rate in intelligent clothing with distributed FBG are studied, the mathematical models of human physiological parameters measurement are built; the processing method of body temperature and heart rate detection signals is presented; human physiological parameters detection module is designed, the interference signals are filtered out, and the measurement accuracy is improved; the integration of the intelligent clothing is given. The intelligent clothing can implement real-time measurement, processing, storage and output of body temperature and heart rate. It has accurate measurement, portability, low cost, real-time monitoring, and other advantages. The intelligent clothing can realize the non-contact monitoring between doctors and patients, timely find the diseases such as cancer and infectious diseases, and make patients get timely treatment. It has great significance and value for ensuring the health of the elders and the children with language dysfunction.

  13. Shirodhara: A psycho-physiological profile in healthy volunteers.

    PubMed

    Dhuri, Kalpana D; Bodhe, Prashant V; Vaidya, Ashok B

    2013-01-01

    Shirodhara is a classical and a well-established ayurvedic procedure of slowly and steadily dripping medicated oil or other liquids on the forehead. This procedure induces a relaxed state of awareness that results in a dynamic psycho-somatic balance. The objective of the study is to evaluate the psychological and physiological effects of Shirodhara in healthy volunteers by monitoring the rating of mood and levels of stress, electrocardiogram (ECG), electroencephalogram (EEG), and selected biochemical markers of stress. The study was conducted in the human pharmacology laboratory. The study design was open labeled, comparing the baseline variables with values after Shirodhara. The subjects (n = 16) chosen were healthy human volunteers who gave an informed consent. Shirodhara was preceded by Abhyanga - whole body massage. The Shirodhara method was standardized for rate of dripping with peristaltic pump and temperature was controlled with a thermostat. Mood and stress levels were assessed by validated rating scales. The pre- and post-Shirodhara ECG and EEG records were evaluated. Student's paired "t" test was applied to the means + SE of the variables to calculate statistical significance at P <0.05. There was a significant improvement in mood scores and the level of stress (P <0.001). These changes were accompanied by significant decrease in rate of breathing and reduction in diastolic blood pressure along with reduction in heart rate. The relaxed alert state, after Shirodhara, was co-related with an increase in alfa rhythm in EEG. A standardized Shirodhara leads to a state of alert calmness similar to the relaxation response observed in meditation. The clinical benefits observed with Shirodhara in anxiety neurosis, hypertension, and stress aggravation due to chronic degenerative diseases could be mediated through these adaptive physiological effects.

  14. Shirodhara: A psycho-physiological profile in healthy volunteers

    PubMed Central

    Dhuri, Kalpana D.; Bodhe, Prashant V.; Vaidya, Ashok B.

    2013-01-01

    Background: Shirodhara is a classical and a well-established ayurvedic procedure of slowly and steadily dripping medicated oil or other liquids on the forehead. This procedure induces a relaxed state of awareness that results in a dynamic psycho-somatic balance. Objectives: The objective of the study is to evaluate the psychological and physiological effects of Shirodhara in healthy volunteers by monitoring the rating of mood and levels of stress, electrocardiogram (ECG), electroencephalogram (EEG), and selected biochemical markers of stress. Materials and Methods: The study was conducted in the human pharmacology laboratory. The study design was open labeled, comparing the baseline variables with values after Shirodhara. The subjects (n = 16) chosen were healthy human volunteers who gave an informed consent. Shirodhara was preceded by Abhyanga – whole body massage. The Shirodhara method was standardized for rate of dripping with peristaltic pump and temperature was controlled with a thermostat. Mood and stress levels were assessed by validated rating scales. The pre- and post-Shirodhara ECG and EEG records were evaluated. Results: Student's paired “t” test was applied to the means + SE of the variables to calculate statistical significance at P <0.05. There was a significant improvement in mood scores and the level of stress (P <0.001). These changes were accompanied by significant decrease in rate of breathing and reduction in diastolic blood pressure along with reduction in heart rate. The relaxed alert state, after Shirodhara, was co-related with an increase in alfa rhythm in EEG. Conclusion: A standardized Shirodhara leads to a state of alert calmness similar to the relaxation response observed in meditation. The clinical benefits observed with Shirodhara in anxiety neurosis, hypertension, and stress aggravation due to chronic degenerative diseases could be mediated through these adaptive physiological effects. PMID:23741161

  15. Utilizing Landsat 8 to measure kelp physiological health in the Santa Barbara Channel

    NASA Astrophysics Data System (ADS)

    Taylor, N.; Bausell, J.; Bell, T. W.; Kudela, R. M.; Scuderi, L. A.

    2017-12-01

    Giant Kelp (Macrocystis pyrifera) is an important primary producer and ecosystem engineer along the west coast of North America. While satellite sensors can easily quantify canopy area of kelp, gauging the physiological health of these macroalgae has proven more difficult. Bell et al. (2015) devised an algorithm that effectively estimated the chlorophyll to carbon ratio (Chl:C)—a proxy for kelp health—using AVIRIS imagery. However while AVIRIS shows great potential in mapping kelp forest health, as an airborne sensor its availability is inconsistent over time, making it less ideal for continuous kelp forest monitoring. We therefore extend this method of determining Chl:C based on reflectance values to Landsat 8 satellite imagery. Landsat 8 Level 2 reflectance was confined to within one standard deviation of the best fit line to exclude outliers, and used to generate an equation for estimating Chl:C. The construction of a Landsat time series using this algorithm spanning 2013-2015 displays a predictable seasonal cycle of physiological health. These seasonal shifts in Chl:C suggest that kelp physiology is closely linked to environmental conditions and total biomass. Similarly, the lower Chl:C of Isla Vista observed in 2015 could be caused by environmental stressors associated with El Niño such as increased sea surface temperature, decreased nutrient availability, and disturbance. The added implementation of Landsat to estimate health greatly increases the potential for understanding long and short-term variability in photosynthetic ability and growth rates of kelp forests.

  16. A Multimodal Database for a Home Remote Medical Care Application

    NASA Astrophysics Data System (ADS)

    Medjahed, Hamid; Istrate, Dan; Boudy, Jerome; Steenkeste, François; Baldinger, Jean-Louis; Dorizzi, Bernadette

    The home remote monitoring systems aim to make a protective contribution to the well being of individuals (patients, elderly persons) requiring moderate amounts of support for independent living spaces, and improving their everyday life. Existing researches of these systems suffer from lack of experimental data and a standard medical database intended for their validation and improvement. This paper presents a multi-sensors environment for acquiring and recording a multimodal medical database, which includes physiological data (cardiac frequency, activity or agitation, posture, fall), environment sounds and localization data. It provides graphical interface functions to manage, process and index these data. The paper focuses on the system implementation, its usage and it points out possibilities for future work.

  17. Heart rate monitoring in soccer: interest and limits during competitive match play and training, practical application.

    PubMed

    Alexandre, Dellal; da Silva, Cristiano Diniz; Hill-Haas, Stephen; Wong, Del P; Natali, Antonio J; De Lima, Jorge R P; Bara Filho, Mauricio G B; Marins, Joao J C B; Garcia, Emerson Silami; Karim, Chamari

    2012-10-01

    The identification of physiological loads imposed by soccer training or match play reveals essential information, which may help improve training and recovery strategies. Until today, the use of heart rate (HR) monitoring is not standardized in soccer. Thus, the aim of this review was to analyze, determine and compare the exercise intensity (EI) monitored by HR in professional, youth, and recreational soccer players during matches and training sessions using a meta-analysis. Heart rate is one of the most common physiological variables used to determine exercise internal training load. The mean EI recorded during competitive matches was described as 70-80% of VO2max or 80-90% of maximal heart rate (HRmax), independent of the playing level. With respect to HR training zones, approximately 65% of the total match duration is spent at intensity of 70-90% HRmax and rarely below 65% HRmax. However, although HRmax is mostly employed in the literature, monitoring EI should be expressed in relation to reserve heart rate, as it was described as a more reliable indicator of HR, allowing interindividual comparisons. The HR response according to the playing position indicates that midfielders are characterized by the highest EI, followed by forwards and fullbacks. Moreover, in the second half of the match, the EI is lower than that observed during the first half; this reduction could be correlated with the level of the player's physical conditioning. Consequently, coaches may favor the use of interval training or small-sided training games because these are shown to improve both aerobic capacity and the ability to repeat high-intensity actions. Small-sided games allow reaching similar HR responses to those found during interval training and match play but with greater heterogeneity values. Future investigations should include a larger sample of players with special reference to playing position and the expression of EI in percentage of the reserve heart rate, analyzing the possible intergender differences in HR response.

  18. Evaluating the physiological and behavioral response of a male and female gorilla (Gorilla gorilla gorilla) during an introduction.

    PubMed

    Jacobs, Raechel M; Ross, Stephen R; Wagner, Katherine E; Leahy, Maureen; Meiers, Susan T; Santymire, Rachel M

    2014-01-01

    Prolonged stress responses can lead to infertility and death; therefore monitoring respective indicators like stress-related hormones and behaviors is an important tool in ensuring the health and well-being among zoo-housed animal populations. Changes in social structure, such as the introduction of a new conspecific, can be a source of stress. In April 2010, a sexually mature female western lowland gorilla (Gorilla gorilla gorilla) was brought to Lincoln Park Zoo (LPZ; Chicago, IL) from the Chicago Zoological Park (Brookfield, IL) for a breeding recommendation from the Gorilla Species Survival Plan. Fecal glucocorticoid metabolites (FGMs) were monitored in two gorillas prior to, during and immediately following the social introduction. Reproduction events, such ovarian cyclicity and pregnancy, were monitored using behavior and fecal progestagen metabolite (FPM; female) and fecal androgen metabolite (FAM; male) analyses. Mean (± standard error) FGM concentrations for the male were elevated (P = 0.002) during the introduction (20.61 ± 0.83 ng/g) compared to the pre- and post-introduction phases (11.31 ± 0.48 ng/g and 12.42 ± 0.65 ng/g, respectively). For the female, mean FGM concentrations were lower (P < 0.001) during the post-introduction (17.91 ± 1.07 ng/g) than during the pre- and introduction phases (30.50 ± 3.42 and 27.38 ± 1.51 ng/g, respectively). The female maintained normal FPM cyclicity throughout the study and became pregnant in the post-introduction phase. These results suggest the importance of both behavioral and physiological monitoring of zoo animals and demonstrate the potential stress that can occur during social introductions. Zoo Biol. 33:394-402, 2014. © 2014 Wiley Periodicals Inc. © 2014 Wiley Periodicals, Inc.

  19. Body Temperature Monitoring Using Subcutaneously Implanted Thermo-loggers from Holstein Steers

    PubMed Central

    Lee, Y.; Bok, J. D.; Lee, H. J.; Lee, H. G.; Kim, D.; Lee, I.; Kang, S. K.; Choi, Y. J.

    2016-01-01

    Body temperature (BT) monitoring in cattle could be used to early detect fever from infectious disease or physiological events. Various ways to measure BT have been applied at different locations on cattle including rectum, reticulum, milk, subcutis and ear canal. In other to evaluate the temperature stability and reliability of subcutaneous temperature (ST) in highly fluctuating field conditions for continuous BT monitoring, long term ST profiles were collected and analyzed from cattle in autumn/winter and summer season by surgically implanted thermo-logger devices. Purposes of this study were to assess ST in the field condition as a reference BT and to determine any location effect of implantation on ST profile. In results, ST profile in cattle showed a clear circadian rhythm with daily lowest at 05:00 to 07:00 AM and highest around midnight and rather stable temperature readings (mean±standard deviation [SD], 37.1°C to 37.36°C±0.91°C to 1.02°C). STs are 1.39°C to 1.65°C lower than the rectal temperature and sometimes showed an irregular temperature drop below the normal physiologic one: 19.4% or 36.4% of 54,192 readings were below 36.5°C or 37°C, respectively. Thus, for BT monitoring purposes in a fever-alarming-system, a correction algorithm is necessary to remove the influences of ambient temperature and animal resting behavior especially in winter time. One way to do this is simply discard outlier readings below 36.5°C or 37°C resulting in a much improved mean±SD of 37.6°C±0.64°C or 37.8°C±0.55°C, respectively. For location the upper scapula region seems the most reliable and convenient site for implantation of a thermo-sensor tag in terms of relatively low influence by ambient temperature and easy insertion compared to lower scapula or lateral neck. PMID:26732455

  20. [A wireless mobile monitoring system based on bluetooth technology].

    PubMed

    Sun, Shou-jun; Wu, Kai; Wu, Xiao-Ming

    2006-09-01

    This paper presents a wireless mobile monitoring system based on Bluetooth technology. This system realizes the remote mobile monitoring of multiple physiological parameters, and has the characters of easy use, low cost, good reliability and strong capability of anti-jamming.

  1. A low-power multi-modal body sensor network with application to epileptic seizure monitoring.

    PubMed

    Altini, Marco; Del Din, Silvia; Patel, Shyamal; Schachter, Steven; Penders, Julien; Bonato, Paolo

    2011-01-01

    Monitoring patients' physiological signals during their daily activities in the home environment is one of the challenge of the health care. New ultra-low-power wireless technologies could help to achieve this goal. In this paper we present a low-power, multi-modal, wearable sensor platform for the simultaneous recording of activity and physiological data. First we provide a description of the wearable sensor platform, and its characteristics with respect to power consumption. Second we present the preliminary results of the comparison between our sensors and a reference system, on healthy subjects, to test the reliability of the detected physiological (electrocardiogram and respiration) and electromyography signals.

  2. Absolute quantification of Dehalococcoides proteins: enzyme bioindicators of chlorinated ethene dehalorespiration.

    PubMed

    Werner, Jeffrey J; Ptak, A Celeste; Rahm, Brian G; Zhang, Sheng; Richardson, Ruth E

    2009-10-01

    The quantification of trace proteins in complex environmental samples and mixed microbial communities would be a valuable monitoring tool in countless applications, including the bioremediation of groundwater contaminated with chlorinated solvents. Measuring the concentrations of specific proteins provides unique information about the activity and physiological state of organisms in a sample. We developed sensitive (< 5 fmol), selective bioindicator assays for the absolute quantification of select proteins used by Dehalococcoides spp. when reducing carbon atoms in the common pollutants trichloroethene (TCE) and tetrachloroethene (PCE). From complex whole-sample digests of two different dechlorinating mixed communities, we monitored the chromatographic peaks of selected tryptic peptides chosen to represent 19 specific Dehalococcoides proteins. This was accomplished using multiple-reaction monitoring (MRM) assays using nano-liquid chromatography-tandem mass spectrometry (nLC-MS/MS), which provided the selectivity, sensitivity and reproducibility required to quantify Dehalococcoides proteins in complex samples. We observed reproducible peak areas (average CV = 0.14 over 4 days, n = 3) and linear responses in standard curves (n = 5, R(2) > 0.98) using synthetic peptide standards spiked into a background matrix of sediment peptides. We detected and quantified TCE reductive dehalogenase (TceA) at 7.6 +/- 1.7 x 10(3) proteins cell(-1) in the KB1 bioaugmentation culture, previously thought to be lacking TceA. Fragmentation data from MS/MS shotgun proteomics experiments were helpful in developing the MRM targets. Similar shotgun proteomics data are emerging in labs around the world for many environmentally relevant microbial proteins, and these data are a valuable resource for the future development of MRM assays. We expect targeted peptide quantification in environmental samples to be a useful tool in environmental monitoring.

  3. Human Physiology and the Environment in Health and Disease: Readings from Scientific American.

    ERIC Educational Resources Information Center

    1976

    This anthology of articles is designed to supplement standard texts for courses in human physiology, environmental physiology, anatomy and physiology, pathobiology, general biology, and environmental medicine. It focuses on the influences of the external environment on the body, the physiological responses to environmental challenges, and the ways…

  4. RF Safety Analysis of a Novel Ultra-wideband Fetal Monitoring System.

    PubMed

    Bushberg, Jerrold T; Tupin, J Paul

    2017-05-01

    The LifeWave Ultra-Wideband RF sensor (LWUWBS) is a monitoring solution for a variety of physiologic assessment applications, including maternal fetal monitoring in both the antepartum and intrapartum periods. The system uses extremely low power radio frequency (RF) ultra-wide band (UWB) signals to provide continuous fetal heart rate and contractions monitoring during labor and delivery. Even with the incorporation of three very conservative assumptions, (1) concentration of the RF energy in 1 cm, (2) minimal (2.5 cm) maternal tissue attenuation of fetal exposure, and (3) absence of normal thermoregulatory compensation, the maternal whole body spatial-averaged specific absorption rate (WBSAR) would be 34,000 times below the FCC public exposure limit of 0.08 W kg and, at 8 wk or more gestation, the peak spatial-averaged specific absorption rate (PSSAR) in the fetus would be more than 160 times below the localized exposure limit of 1.6 mW g. Even when using very conservative assumptions, an analysis of the LWUWBS's impact on tissue heating is a factor of 7 lower than what is allowed for fetal ultrasound and at least a factor of 650 compared to fetal MRI. The actual transmitted power levels of the LWUWBS are well below all Federal safety standards, and the potential for tissue heating is substantially lower than associated with current ultrasonic fetal monitors and MRI.

  5. Wearable physiological systems and technologies for metabolic monitoring.

    PubMed

    Gao, Wei; Brooks, George A; Klonoff, David C

    2018-03-01

    Wearable sensors allow continuous monitoring of metabolites for diabetes, sports medicine, exercise science, and physiology research. These sensors can continuously detect target analytes in skin interstitial fluid (ISF), tears, saliva, and sweat. In this review, we will summarize developments on wearable devices and their potential applications in research, clinical practice, and recreational and sporting activities. Sampling skin ISF can require insertion of a needle into the skin, whereas sweat, tears, and saliva can be sampled by devices worn outside the body. The most widely sampled metabolite from a wearable device is glucose in skin ISF for monitoring diabetes patients. Continuous ISF glucose monitoring allows estimation of the glucose concentration in blood without the pain, inconvenience, and blood waste of fingerstick capillary blood glucose testing. This tool is currently used by diabetes patients to provide information for dosing insulin and determining a diet and exercise plan. Similar technologies for measuring concentrations of other analytes in skin ISF could be used to monitor athletes, emergency responders, warfighters, and others in states of extreme physiological stress. Sweat is a potentially useful substrate for sampling analytes for metabolic monitoring during exercise. Lactate, sodium, potassium, and hydrogen ions can be measured in sweat. Tools for converting the concentrations of these analytes sampled from sweat, tears, and saliva into blood concentrations are being developed. As an understanding of the relationships between the concentrations of analytes in blood and easily sampled body fluid increases, then the benefits of new wearable devices for metabolic monitoring will also increase.

  6. Lateralization of spatial information processing in response monitoring

    PubMed Central

    Stock, Ann-Kathrin; Beste, Christian

    2014-01-01

    The current study aims at identifying how lateralized multisensory spatial information processing affects response monitoring and action control. In a previous study, we investigated multimodal sensory integration in response monitoring processes using a Simon task. Behavioral and neurophysiologic results suggested that different aspects of response monitoring are asymmetrically and independently allocated to the hemispheres: while efference-copy-based information on the motor execution of the task is further processed in the hemisphere that originally generated the motor command, proprioception-based spatial information is processed in the hemisphere contralateral to the effector. Hence, crossing hands (entering a “foreign” spatial hemifield) yielded an augmented bilateral activation during response monitoring since these two kinds of information were processed in opposing hemispheres. Because the traditional Simon task does not provide the possibility to investigate which aspect of the spatial configuration leads to the observed hemispheric allocation, we introduced a new “double crossed” condition that allows for the dissociation of internal/physiological and external/physical influences on response monitoring processes. Comparing behavioral and neurophysiologic measures of this new condition to those of the traditional Simon task setup, we could demonstrate that the egocentric representation of the physiological effector's spatial location accounts for the observed lateralization of spatial information in action control. The finding that the location of the physical effector had a very small influence on response monitoring measures suggests that this aspect is either less important and/or processed in different brain areas than egocentric physiological information. PMID:24550855

  7. Interrenal dysfunction in fish from contaminated sites: In vivo and in vitro studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hontela, A.

    1995-12-31

    An endocrine impairment characterized by a reduced capacity to elevate plasma cortisol levels in response to an acute standardized capture stress, has been previously diagnosed in yellow perch, Perca flavescens, and in northern pike, Esox lucius, from sites contaminated by mixtures of pollutants (heavy metals, PAHs and PCBs) or by BKME. The most recent studies were designed to (1) field validate this dysfunction usable as a marker of reduced physiological competence in fish; (2) demonstrate the impairment of the interrenal tissue in fish from sites located in a mining region in Abitibi; and (3) elucidate the physiological mechanisms underlying themore » impairment of the interrenal tissue in fish chronically exposed to xenobiotics. The responsiveness of the interrenal tissue to a standardized dose of ACTH1-39 was assessed in vivo in yellow perch from contaminated and reference sites maintained in experimental enclosures, as well as in vitro using complete growth medium in a perifusion system and in microplates. The results showed that the functional impairment of the internal tissue in fish exposed to xenobiotics is an exposure related phenomenon modulated by season. The functional tests with the interrenal tissue revealed that the responsiveness to ACTH is significantly reduced and that the synthesis of cortisol is disrupted, in fish from contaminated sites. Use of the functional ACTH-tests with the interrenal tissue of fish in environmental monitoring will be discussed.« less

  8. Acoustic monitoring of first responder's physiology for health and performance surveillance

    NASA Astrophysics Data System (ADS)

    Scanlon, Michael V.

    2002-08-01

    Acoustic sensors have been used to monitor firefighter and soldier physiology to assess health and performance. The Army Research Laboratory has developed a unique body-contacting acoustic sensor that can monitor the health and performance of firefighters and soldiers while they are doing their mission. A gel-coupled sensor has acoustic impedance properties similar to the skin that facilitate the transmission of body sounds into the sensor pad, yet significantly repel ambient airborne noises due to an impedance mismatch. This technology can monitor heartbeats, breaths, blood pressure, motion, voice, and other indicators that can provide vital feedback to the medics and unit commanders. Diverse physiological parameters can be continuously monitored with acoustic sensors and transmitted for remote surveillance of personnel status. Body-worn acoustic sensors located at the neck, breathing mask, and wrist do an excellent job at detecting heartbeats and activity. However, they have difficulty extracting physiology during rigorous exercise or movements due to the motion artifacts sensed. Rigorous activity often indicates that the person is healthy by virtue of being active, and injury often causes the subject to become less active or incapacitated making the detection of physiology easier. One important measure of performance, heart rate variability, is the measure of beat-to-beat timing fluctuations derived from the interval between two adjacent beats. The Lomb periodogram is optimized for non-uniformly sampled data, and can be applied to non-stationary acoustic heart rate features (such as 1st and 2nd heart sounds) to derive heart rate variability and help eliminate errors created by motion artifacts. Simple peak-detection above or below a certain threshold or waveform derivative parameters can produce the timing and amplitude features necessary for the Lomb periodogram and cross-correlation techniques. High-amplitude motion artifacts may contribute to a different frequency or baseline noise due to the timing differences between the noise artifacts and heartbeat features. Data from a firefighter experiment is presented.

  9. Lunar Health Monitor (LHM)

    NASA Technical Reports Server (NTRS)

    Lisy, Frederick J.

    2015-01-01

    Orbital Research, Inc., has developed a low-profile, wearable sensor suite for monitoring astronaut health in both intravehicular and extravehicular activities. The Lunar Health Monitor measures respiration, body temperature, electrocardiogram (EKG) heart rate, and other cardiac functions. Orbital Research's dry recording electrode is central to the innovation and can be incorporated into garments, eliminating the need for conductive pastes, adhesives, or gels. The patented dry recording electrode has been approved by the U.S. Food and Drug Administration. The LHM is easily worn under flight gear or with civilian clothing, making the system completely versatile for applications where continuous physiological monitoring is needed. During Phase II, Orbital Research developed a second-generation LHM that allows sensor customization for specific monitoring applications and anatomical constraints. Evaluations included graded exercise tests, lunar mission task simulations, functional battery tests, and resting measures. The LHM represents the successful integration of sensors into a wearable platform to capture long-duration and ambulatory physiological markers.

  10. Monitoring and diagnosis of Alzheimer's disease using noninvasive compressive sensing EEG

    NASA Astrophysics Data System (ADS)

    Morabito, F. C.; Labate, D.; Morabito, G.; Palamara, I.; Szu, H.

    2013-05-01

    The majority of elderly with Alzheimer's Disease (AD) receive care at home from caregivers. In contrast to standard tethered clinical settings, a wireless, real-time, body-area smartphone-based remote monitoring of electroencephalogram (EEG) can be extremely advantageous for home care of those patients. Such wearable tools pave the way to personalized medicine, for example giving the opportunity to control the progression of the disease and the effect of drugs. By applying Compressive Sensing (CS) techniques it is in principle possible to overcome the difficulty raised by smartphones spatial-temporal throughput rate bottleneck. Unfortunately, EEG and other physiological signals are often non-sparse. In this paper, it is instead shown that the EEG of AD patients becomes actually more compressible with the progression of the disease. EEG of Mild Cognitive Impaired (MCI) subjects is also showing clear tendency to enhanced compressibility. This feature favor the use of CS techniques and ultimately the use of telemonitoring with wearable sensors.

  11. Clinical and diagnostic utility of saliva as a non-invasive diagnostic fluid:
a systematic review

    PubMed Central

    Nunes, Lazaro Alessandro Soares; Mussavira, Sayeeda

    2015-01-01

    This systematic review presents the latest trends in salivary research and its applications in health and disease. Among the large number of analytes present in saliva, many are affected by diverse physiological and pathological conditions. Further, the non-invasive, easy and cost-effective collection methods prompt an interest in evaluating its diagnostic or prognostic utility. Accumulating data over the past two decades indicates towards the possible utility of saliva to monitor overall health, diagnose and treat various oral or systemic disorders and drug monitoring. Advances in saliva based systems biology has also contributed towards identification of several biomarkers, development of diverse salivary diagnostic kits and other sensitive analytical techniques. However, its utilization should be carefully evaluated in relation to standardization of pre-analytical and analytical variables, such as collection and storage methods, analyte circadian variation, sample recovery, prevention of sample contamination and analytical procedures. In spite of all these challenges, there is an escalating evolution of knowledge with the use of this biological matrix. PMID:26110030

  12. The study of pain with blood oxygen level dependent functional magnetic resonance imaging

    NASA Astrophysics Data System (ADS)

    Ibinson, James W.

    Using blood oxygen level dependent functional magnetic resonance imaging (BOLD FMRI), the brain areas activated by pain were studied. These initial studies led to interesting new findings about the body's response to pain and to the refinement of one method used in FMRI analysis for correction of physiologic noise (signal fluctuations caused by the cyclic and non-cyclic changes in the cardiovascular and respiratory status of the body). In the first study, evidence was provided suggesting that the multiple painful stimulations used in typical pain FMRI block designs may cause attenuation over time of the BOLD signal within activated areas. The effect this may have on pain investigations using multiple tasks has not been previously investigated. The demonstrated BOLD attenuation seems unique to pain studies. Several possible explanations exist, but two of the most likely are neural activity modulation by descending pain inhibitory mechanisms and changing hemodynamics caused by a physiologic response to pain. The second study began the investigation of hemodynamics by monitoring the physiologic response to pain for eight subjects in two phases. Phase one used a combination of standard operating suite monitors and research equipment to characterizing the physiologic response to pain. Phase two collected magnetic resonance quantitative flow images during painful nerve stimulation to test for changes in global cerebral blood flow. It is well established that changes in respiration and global blood flow can affect the BOLD response, leading to the final investigation of this dissertation. The brain activation induced by pain for the same eight subjects used in the physiologic response experiments described above was then studied by BOLD FMRI. By including the respiration signal and end-tidal carbon dioxide levels in the analysis of the images, the quantification and removal of image intensity variations correlated to breathing and end-tidal carbon dioxide changes could be performed. The technique generally accepted for this analysis, however, uses respiration signals averaged over a 3 second period. Because normal respiratory rate is approximately one breath every 3 to 5 seconds, it was hypothesized that performing the correction using the average breathing data set would miss much of the actual respiration induced variation in each image. Therefore, a new technique for removing signal that covaries with the actual breathing values present during the collection of each image was introduced. (Abstract shortened by UMI.)

  13. Novel Techniques for Retroperitoneal Implantation of Telemetry Transmitters for Physiologic Monitoring in Gottingen Minipigs (Sus scrofa domesticus)

    DTIC Science & Technology

    2014-12-01

    scrofa domesticus) Scott Willens,1,* David M Cox,3 Ernest H Braue,1 Todd M Myers,1 and Matthew D Wegner2 Telemetric monitoring of physiologic parameters...BMC Vet Res 4:51. 15. Hulet SW, Sommerville DR, Crosier RB, Dabisch PA, Miller DB, Benton BJ, Forster JS, Scotto JA, Jarvis JR , Krauthauser C...domestic white pig. Basic Clin Pharmacol Toxicol 97:35–38. 6. Crawshaw GJ, Mills KJ, Mosley C, Patterson BR. 2007. Field im- plantation of

  14. Human factors approach to evaluate the user interface of physiologic monitoring.

    PubMed

    Fidler, Richard; Bond, Raymond; Finlay, Dewar; Guldenring, Daniel; Gallagher, Anthony; Pelter, Michele; Drew, Barbara; Hu, Xiao

    2015-01-01

    As technology infiltrates more of our personal and professional lives, user expectations for intuitive design have driven many consumer products, while medical equipment continues to have high training requirements. Not much is known about the usability and user experience associated with hospital monitoring equipment. This pilot project aimed to better understand and describe the user interface interaction and user experience with physiologic monitoring technology. This was a prospective, descriptive, mixed-methods quality improvement project to analyze perceptions and task analyses of physiologic monitors. Following a survey of practice patterns and perceived abilities to accomplish key tasks, 10 voluntary experienced physician and nurse subjects were asked to perform a series of tasks in 7 domains of monitor operations on GE Monitoring equipment in a single institution. For each task analysis, data were collected on time to complete the task, the number of button pushes or clicks required to accomplish the task, economy of motion, and observed errors. Although 60% of the participants reported incorporating monitoring data into patient care, 80% of participants preferred to receive monitoring data at the point of care (bedside). Average perceived central station usability is 5.3 out of 10 (ten is easiest). High variability exists in monitoring station interaction performance among those participating in this project. Alarms were almost universally silenced without cognitive recognition of the alarm state. Education related to monitoring operations appeared largely absent in this sample. Most users perceived the interface to not be intuitive, complaining of multiple layers and steps for data retrieval. These clinicians report real-time monitoring helpful for abrupt changes in condition like arrhythmias; however, reviewing alarms is not prioritized as valuable due to frequent false alarms. Participants requested exporting monitoring data to electronic medical records. Much research is needed to develop best practices for display of real-time information, organization and filtering of meaningful data, and simplified ways to find information. Published by Elsevier Inc.

  15. Preventing and Treating Hypoxia: Using a Physiology Simulator to Demonstrate the Value of Pre-Oxygenation and the Futility of Hyperventilation.

    PubMed

    Lerant, Anna A; Hester, Robert L; Coleman, Thomas G; Phillips, William J; Orledge, Jeffrey D; Murray, W Bosseau

    2015-01-01

    Insufficient pre-oxygenation before emergency intubation, and hyperventilation after intubation are mistakes that are frequently observed in and outside the operating room, in clinical practice and in simulation exercises. Physiological parameters, as appearing on standard patient monitors, do not alert to the deleterious effects of low oxygen saturation on coronary perfusion, or that of low carbon dioxide concentrations on cerebral perfusion. We suggest the use of HumMod, a computer-based human physiology simulator, to demonstrate beneficial physiological responses to pre-oxygenation and the futility of excessive minute ventilation after intubation. We programmed HumMod, to A.) compare varying times (0-7 minutes) of pre-oxygenation on oxygen saturation (SpO2) during subsequent apnoea; B.) simulate hyperventilation after apnoea. We compared the effect of different minute ventilation rates on SpO2, acid-base status, cerebral perfusion and other haemodynamic parameters. A.) With no pre-oxygenation, starting SpO2 dropped from 98% to 90% in 52 seconds with apnoea. At the other extreme, following full pre-oxygenation with 100% O2 for 3 minutes or more, the SpO2 remained 100% for 7.75 minutes during apnoea, and dropped to 90% after another 75 seconds. B.) Hyperventilation, did not result in more rapid normalization of SpO2, irrespective of the level of minute ventilation. However, hyperventilation did cause significant decreases in cerebral blood flow (CBF). HumMod accurately simulates the physiological responses compared to published human studies of pre-oxygenation and varying post intubation minute ventilations, and it can be used over wider ranges of parameters than available in human studies and therefore available in the literature.

  16. Preventing and Treating Hypoxia: Using a Physiology Simulator to Demonstrate the Value of Pre-Oxygenation and the Futility of Hyperventilation

    PubMed Central

    Lerant, Anna A.; Hester, Robert L.; Coleman, Thomas G.; Phillips, William J.; Orledge, Jeffrey D.; Murray, W. Bosseau

    2015-01-01

    Introduction: Insufficient pre-oxygenation before emergency intubation, and hyperventilation after intubation are mistakes that are frequently observed in and outside the operating room, in clinical practice and in simulation exercises. Physiological parameters, as appearing on standard patient monitors, do not alert to the deleterious effects of low oxygen saturation on coronary perfusion, or that of low carbon dioxide concentrations on cerebral perfusion. We suggest the use of HumMod, a computer-based human physiology simulator, to demonstrate beneficial physiological responses to pre-oxygenation and the futility of excessive minute ventilation after intubation. Methods: We programmed HumMod, to A.) compare varying times (0-7 minutes) of pre-oxygenation on oxygen saturation (SpO2) during subsequent apnoea; B.) simulate hyperventilation after apnoea. We compared the effect of different minute ventilation rates on SpO2, acid-base status, cerebral perfusion and other haemodynamic parameters. Results: A.) With no pre-oxygenation, starting SpO2 dropped from 98% to 90% in 52 seconds with apnoea. At the other extreme, following full pre-oxygenation with 100% O2 for 3 minutes or more, the SpO2 remained 100% for 7.75 minutes during apnoea, and dropped to 90% after another 75 seconds. B.) Hyperventilation, did not result in more rapid normalization of SpO2, irrespective of the level of minute ventilation. However, hyperventilation did cause significant decreases in cerebral blood flow (CBF). Conclusions: HumMod accurately simulates the physiological responses compared to published human studies of pre-oxygenation and varying post intubation minute ventilations, and it can be used over wider ranges of parameters than available in human studies and therefore available in the literature. PMID:26283881

  17. Real-time in vivo uric acid biosensor system for biophysical monitoring of birds.

    PubMed

    Gumus, A; Lee, S; Karlsson, K; Gabrielson, R; Winkler, D W; Erickson, D

    2014-02-21

    Research on birds has long played an important role in ecological investigations, as birds are relatively easily observed, and their high metabolic rates and diurnal habits make them quite evidently responsive to changes in their environments. A mechanistic understanding of such avian responses requires a better understanding of how variation in physiological state conditions avian behavior and integrates the effects of recent environmental changes. There is a great need for sensor systems that will allow free-flying birds to interact with their environment and make unconstrained decisions about their spatial location at the same time that their physiological state is being monitored in real time. We have developed a miniature needle-based enzymatic sensor system suitable for continuous real-time amperometric monitoring of uric acid levels in unconstrained live birds. The sensor system was constructed with Pt/Ir wire and Ag/AgCl paste. Uricase enzyme was immobilized on a 0.7 mm sensing cavity of Nafion/cellulose inner membrane to minimize the influences of background interferents. The sensor response was linear from 0.05 to 0.6 mM uric acid, which spans the normal physiological range for most avian species. We developed a two-electrode potentiostat system that drives the biosensor, reads the output current, and wirelessly transmits the data. In addition to extensive characterization of the sensor and system, we also demonstrate autonomous operation of the system by collecting in vivo extracellular uric acid measurements on a domestic chicken. The results confirm our needle-type sensor system's potential for real-time monitoring of birds' physiological state. Successful application of the sensor in migratory birds could open up a new era of studying both the physiological preparation for migration and the consequences of sustained avian flight.

  18. Standard versus physiologic bone preparation in total knee arthroplasty and the effect on joint space opening.

    PubMed

    Burkhart, Timothy A; Herman, Benjamin V; Perry, Kevin; Vandekerckhove, Pieter-Jan; Howard, James; Lanting, Brent

    2017-11-01

    Total knee arthroplasty is an effective treatment for osteoarthritis. Restoration of physiologic varus alignment may restore the native soft tissue tension and improve outcomes. Six paired fresh-frozen knee specimens were used to perform total knee arthroplastys. The left and right sides of were randomly assigned to have either a physiologic alignment cut or a standard of care neutral alignment bony cut prior to the implantation. Loads of 100 and 200N were applied at 0, 30, 60, and 90° of flexion and the magnitude of the medial and lateral compartment distraction was measured. The loads were applied with the knee specimen intact and post arthroplasty. The physiologic alignment had no difference between medial and lateral gaps at either load. With 100N of load the physiologic alignment had a greater gap at 90° than at full extension while the standard alignment had significantly more gap at 60° of flexion than full extension. The physiologic alignment had a significantly greater gap with the implant compared to the intact condition at both loads. The standard alignment had no significant difference in overall gap between the implant and intact condition with any load. Although performing a physiologic aligned TKA resulted in medial-lateral soft tissue balance, the flexion gap was found to have greater magnitude than the intact knee. Notably, a neutral aligned TKA was found to be balanced, but also was found to recreate the intact knee flexion gaps. These results suggest that coronal plane stability can be achieved with physiologic alignment objectives, but the clinician needs to be aware of the potential to have greater laxity than the intact and neutral alignment surgical objectives. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. On the use of wearable physiological monitors to assess heat strain during occupational heat stress.

    PubMed

    Notley, Sean R; Flouris, Andreas D; Kenny, Glen P

    2018-05-04

    Workers in many industries are required to perform arduous work in high heat stress conditions, which can lead to rapid increases in body temperature that elevate the risk of heat-related illness or even death. Traditionally, effort to mitigate work-related heat injury has been directed to the assessment of environmental heat stress (e.g., wet-bulb globe temperature), rather than the associated physiological strain responses (e.g., heart rate, skin and core temperatures). However, since a workers physiological response to a given heat stress is modified independently by inter-individual factors (e.g., age, sex, chronic disease, others) and intra-individual factors both within (e.g., medication use, fitness, acclimation and hydration state, others) and beyond a workers control (e.g., shift duration, illness, others), it becomes challenging to protect workers on an individual basis from heat-related injury without assessing those physiological responses. Recent advancements in wearable technology have made it possible to monitor one or more physiological indices of heat strain. Nonetheless, information on the utility of the wearable systems available for assessing occupational heat strain is unavailable. This communication is therefore directed at identifying the physiological indices of heat strain that may be quantified in the workplace and evaluating the wearable monitoring systems available for assessing those responses. Finally, emphasis is directed to the barriers associated with implementing these devices to assist in mitigating work-related heat injury. This information is fundamental for protecting worker health and could also be utilized to prevent heat illnesses in vulnerable people during leisure or athletic activities in the heat.

  20. Continuous wireless pressure monitoring and mapping with ultra-small passive sensors for health monitoring and critical care

    NASA Astrophysics Data System (ADS)

    Chen, Lisa Y.; Tee, Benjamin C.-K.; Chortos, Alex L.; Schwartz, Gregor; Tse, Victor; J. Lipomi, Darren; Wong, H.-S. Philip; McConnell, Michael V.; Bao, Zhenan

    2014-10-01

    Continuous monitoring of internal physiological parameters is essential for critical care patients, but currently can only be practically achieved via tethered solutions. Here we report a wireless, real-time pressure monitoring system with passive, flexible, millimetre-scale sensors, scaled down to unprecedented dimensions of 1 × 1 × 0.1 cubic millimeters. This level of dimensional scaling is enabled by novel sensor design and detection schemes, which overcome the operating frequency limits of traditional strategies and exhibit insensitivity to lossy tissue environments. We demonstrate the use of this system to capture human pulse waveforms wirelessly in real time as well as to monitor in vivo intracranial pressure continuously in proof-of-concept mice studies using sensors down to 2.5 × 2.5 × 0.1 cubic millimeters. We further introduce printable wireless sensor arrays and show their use in real-time spatial pressure mapping. Looking forward, this technology has broader applications in continuous wireless monitoring of multiple physiological parameters for biomedical research and patient care.

  1. Continuous wireless pressure monitoring and mapping with ultra-small passive sensors for health monitoring and critical care.

    PubMed

    Chen, Lisa Y; Tee, Benjamin C-K; Chortos, Alex L; Schwartz, Gregor; Tse, Victor; Lipomi, Darren J; Wong, H-S Philip; McConnell, Michael V; Bao, Zhenan

    2014-10-06

    Continuous monitoring of internal physiological parameters is essential for critical care patients, but currently can only be practically achieved via tethered solutions. Here we report a wireless, real-time pressure monitoring system with passive, flexible, millimetre-scale sensors, scaled down to unprecedented dimensions of 1 × 1 × 0.1 cubic millimeters. This level of dimensional scaling is enabled by novel sensor design and detection schemes, which overcome the operating frequency limits of traditional strategies and exhibit insensitivity to lossy tissue environments. We demonstrate the use of this system to capture human pulse waveforms wirelessly in real time as well as to monitor in vivo intracranial pressure continuously in proof-of-concept mice studies using sensors down to 2.5 × 2.5 × 0.1 cubic millimeters. We further introduce printable wireless sensor arrays and show their use in real-time spatial pressure mapping. Looking forward, this technology has broader applications in continuous wireless monitoring of multiple physiological parameters for biomedical research and patient care.

  2. A survey on signals and systems in ambulatory blood pressure monitoring using pulse transit time.

    PubMed

    Buxi, Dilpreet; Redouté, Jean-Michel; Yuce, Mehmet Rasit

    2015-03-01

    Blood pressure monitoring based on pulse transit or arrival time has been the focus of much research in order to design ambulatory blood pressure monitors. The accuracy of these monitors is limited by several challenges, such as acquisition and processing of physiological signals as well as changes in vascular tone and the pre-ejection period. In this work, a literature survey covering recent developments is presented in order to identify gaps in the literature. The findings of the literature are classified according to three aspects. These are the calibration of pulse transit/arrival times to blood pressure, acquisition and processing of physiological signals and finally, the design of fully integrated blood pressure measurement systems. Alternative technologies as well as locations for the measurement of the pulse wave signal should be investigated in order to improve the accuracy during calibration. Furthermore, the integration and validation of monitoring systems needs to be improved in current ambulatory blood pressure monitors.

  3. Molecular imaging of photodynamic therapy

    NASA Astrophysics Data System (ADS)

    Chang, Sung K.; Errabelli, Divya; Rizvi, Imran; Solban, Nicolas; O'Riordan, Katherine; Hasan, Tayyaba

    2006-02-01

    Recent advances in light sources, detectors and other optical imaging technologies coupled with the development of novel optical contrast agents have enabled real-time, high resolution, in vivo monitoring of molecular targets. Noninvasive monitoring of molecular targets is particularly relevant to photodynamic therapy (PDT), including the delivery of photosensitizer in the treatment site and monitoring of molecular and physiological changes following treatment. Our lab has developed optical imaging technologies to investigate these various aspects of photodynamic therapy (PDT). We used a laser scanning confocal microscope to monitor the pharmacokinetics of various photosensitizers in in vitro as well as ex vivo samples, and developed an intravital fluorescence microscope to monitor photosensitizer delivery in vivo in small animals. A molecular specific contrast agent that targets the vascular endothelial growth factor (VEGF) was developed to monitor the changes in the protein expression following PDT. We were then able to study the physiological changes due to post-treatment VEGF upregulation by quantifying vascular permeability with in vivo imaging.

  4. Digital Health: Tracking Physiomes and Activity Using Wearable Biosensors Reveals Useful Health-Related Information

    PubMed Central

    Zhou, Gao; Zhou, Wenyu; Schüssler-Fiorenza Rose, Sophia Miryam; Perelman, Dalia; Colbert, Elizabeth; Runge, Ryan; Rego, Shannon; Sonecha, Ria; Datta, Somalee; McLaughlin, Tracey; Snyder, Michael P.

    2017-01-01

    A new wave of portable biosensors allows frequent measurement of health-related physiology. We investigated the use of these devices to monitor human physiological changes during various activities and their role in managing health and diagnosing and analyzing disease. By recording over 250,000 daily measurements for up to 43 individuals, we found personalized circadian differences in physiological parameters, replicating previous physiological findings. Interestingly, we found striking changes in particular environments, such as airline flights (decreased peripheral capillary oxygen saturation [SpO2] and increased radiation exposure). These events are associated with physiological macro-phenotypes such as fatigue, providing a strong association between reduced pressure/oxygen and fatigue on high-altitude flights. Importantly, we combined biosensor information with frequent medical measurements and made two important observations: First, wearable devices were useful in identification of early signs of Lyme disease and inflammatory responses; we used this information to develop a personalized, activity-based normalization framework to identify abnormal physiological signals from longitudinal data for facile disease detection. Second, wearables distinguish physiological differences between insulin-sensitive and -resistant individuals. Overall, these results indicate that portable biosensors provide useful information for monitoring personal activities and physiology and are likely to play an important role in managing health and enabling affordable health care access to groups traditionally limited by socioeconomic class or remote geography. PMID:28081144

  5. Physiology in conservation translocations.

    PubMed

    Tarszisz, Esther; Dickman, Christopher R; Munn, Adam J

    2014-01-01

    Conservation translocations aim to restore species to their indigenous ranges, protect populations from threats and/or reinstate ecosystem functions. They are particularly important for the conservation and management of rare and threatened species. Despite tremendous efforts and advancement in recent years, animal conservation translocations generally have variable success, and the reasons for this are often uncertain. We suggest that when little is known about the physiology and wellbeing of individuals either before or after release, it will be difficult to determine their likelihood of survival, and this could limit advancements in the science of translocations for conservation. In this regard, we argue that physiology offers novel approaches that could substantially improve translocations and associated practices. As a discipline, it is apparent that physiology may be undervalued, perhaps because of the invasive nature of some physiological measurement techniques (e.g. sampling body fluids, surgical implantation). We examined 232 publications that dealt with translocations of terrestrial vertebrates and aquatic mammals and, defining 'success' as high or low, determined how many of these studies explicitly incorporated physiological aspects into their protocols and monitoring. From this review, it is apparent that physiological evaluation before and after animal releases could progress and improve translocation/reintroduction successes. We propose a suite of physiological measures, in addition to animal health indices, for assisting conservation translocations over the short term and also for longer term post-release monitoring. Perhaps most importantly, we argue that the incorporation of physiological assessments of animals at all stages of translocation can have important welfare implications by helping to reduce the total number of animals used. Physiological indicators can also help to refine conservation translocation methods. These approaches fall under a new paradigm that we term 'translocation physiology' and represent an important sub-discipline within conservation physiology generally.

  6. Evaluation of a wearable physiological status monitor during simulated fire fighting activities.

    PubMed

    Smith, Denise L; Haller, Jeannie M; Dolezal, Brett A; Cooper, Christopher B; Fehling, Patricia C

    2014-01-01

    A physiological status monitor (PSM) has been embedded in a fire-resistant shirt. The purpose of this research study was to examine the ability of the PSM-shirt to accurately detect heart rate (HR) and respiratory rate (RR) when worn under structural fire fighting personal protective equipment (PPE) during the performance of various activities relevant to fire fighting. Eleven healthy, college-aged men completed three activities (walking, searching/crawling, and ascending/descending stairs) that are routinely performed during fire fighting operations while wearing the PSM-shirt under structural fire fighting PPE. Heart rate and RR recorded by the PSM-shirt were compared to criterion values measured concurrently with an ECG and portable metabolic measurement system, respectively. For all activities combined (overall) and for each activity, small differences were found between the PSM-shirt and ECG (mean difference [95% CI]: overall: -0.4 beats/min [-0.8, -0.1]; treadmill: -0.4 beats/min [-0.7, -0.1]; search: -1.7 beats/min [-3.1, -.04]; stairs: 0.4 beats/min [0.04, 0.7]). Standard error of the estimate was 3.5 beats/min for all tasks combined and 1.9, 5.9, and 1.9 beats/min for the treadmill walk, search, and stair ascent/descent, respectively. Correlations between the PSM-shirt and criterion heart rates were high (r = 0.95 to r = 0.99). The mean difference between RR recorded by the PSM-shirt and criterion overall was 1.1 breaths/min (95% CI: -1.9 to -0.4). The standard error of the estimate for RR ranged from 4.2 breaths/min (treadmill) to 8.2 breaths/min (search), with an overall value of 6.2 breaths/min. These findings suggest that the PSM-shirt provides valid measures of HR and useful approximations of RR when worn during fire fighting duties.

  7. The Electrooculogram and a New Blink Detection Algorithm

    DTIC Science & Technology

    2015-10-30

    applications, and physiological monitoring has proven quite helpful with this assessment. One such physiological signal , the electrooculogram ( EOG ...significantly improve performance. One such physiological signal , the electrooculogram ( EOG ), can provide blink rate and blink duration measures. Blink...that such variability substantiates the need for blink detection algorithms, using the EOG signal , that are robust to noise, artifacts, and intra- and

  8. Medical Electronics and Physiological Measurement.

    ERIC Educational Resources Information Center

    Cochrane, T.

    1989-01-01

    Described are developments in medical electronics and physiological measurement. Discussed are electrocardiology, audiology, and urology as mature applications; applied potential tomography, magnetic stimulation of nerves, and laser Doppler flowmetry as new techniques; and optical sensors, ambulatory monitoring, and biosensors as future…

  9. SmartStuff: A case study of a smart water bottle.

    PubMed

    Jovanov, Emil; Nallathimmareddygari, Vindhya R; Pryor, Jonathan E

    2016-08-01

    The rapid growth of Internet of Things (IoT) and miniature wearable biosensors have generated new opportunities for personalized eHealth and mHealth services. Smart objects equipped with physiological sensors can provide robust monitoring of activities of daily living and context for wearable physiological sensors. We present a case study of an intelligent water bottle that can precisely measure the amount of liquid in the bottle, monitor activity using inertial sensors, and physiological parameters using a touch and photoplethysmographic sensor. We evaluate two system configurations: a smart water bottle integrated into a personal body sensor network and a cloud based device. This paper presents system organization and the results from preliminary field testing of the prototype device.

  10. Measurements, modeling, control and simulation - as applied to the human left ventricle for purposeful physiological monitoring.

    NASA Technical Reports Server (NTRS)

    Ghista, D. N.; Rasmussen, D. N.; Linebarger, R. N.; Sandler, H.

    1971-01-01

    Interdisciplinary engineering research effort in studying the intact human left ventricle has been employed to physiologically monitor the heart and to obtain its 'state-of-health' characteristics. The left ventricle was selected for this purpose because it plays a key role in supplying energy to the body cells. The techniques for measurement of the left ventricular geometry are described; the geometry is effectively displayed to bring out the abnormalities in cardiac function. Methods of mathematical modeling, which make it possible to determine the performance of the intact left ventricular muscle, are also described. Finally, features of a control system for the left ventricle for predicting the effect of certain physiological stress situations on the ventricle performance are discussed.

  11. Design of Plant Eco-physiology Monitoring System Based on Embedded Technology

    NASA Astrophysics Data System (ADS)

    Li, Yunbing; Wang, Cheng; Qiao, Xiaojun; Liu, Yanfei; Zhang, Xinlu

    A real time system has been developed to collect plant's growth information comprehensively. Plant eco-physiological signals can be collected and analyzed effectively. The system adopted embedded technology: wireless sensors network collect the eco-physiological information. Touch screen and ARM microprocessor make the system work independently without PC. The system is versatile and all parameters can be set by the touch screen. Sensors' intelligent compensation can be realized in this system. Information can be displayed by either graphically or in table mode. The ARM microprocessor provides the interface to connect with the internet, so the system support remote monitoring and controlling. The system has advantages of friendly interface, flexible construction and extension. It's a good tool for plant's management.

  12. CAVIAR: an R package for checking, displaying and processing wood-formation-monitoring data.

    PubMed

    Rathgeber, Cyrille B K; Santenoise, Philippe; Cuny, Henri E

    2018-05-19

    In the last decade, the pervasive question of climate change impacts on forests has revived investigations on intra-annual dynamics of wood formation, involving disciplines such as plant ecology, tree physiology and dendrochronology. This resulted in the creation of many research groups working on this topic worldwide and a rapid increase in the number of studies and publications. Wood-formation-monitoring studies are generally based on a common conceptual model describing xylem cell formation as the succession of four differentiation phases (cell division, cell enlargement, cell wall thickening and mature cells). They generally use the same sampling techniques, sample preparation methods and anatomical criteria to separate between differentiation zones and discriminate and count forming xylem cells, resulting in very similar raw data. However, the way these raw data are then processed, producing the elaborated data on which statistical analyses are performed, still remains quite specific to each individual study. Thereby, despite very similar raw data, wood-formation-monitoring studies yield results that are still quite difficult to compare. CAVIAR-an R package specifically dedicated to the verification, visualization and manipulation of wood-formation-monitoring data-can help to improve this situation. Initially, CAVIAR was built to provide efficient algorithms to compute critical dates of wood formation phenology for conifers growing in temperate and cold environments. Recently, we developed it further to check, display and process wood-formation-monitoring data. Thanks to new and upgraded functions, raw data can now be consistently verified, standardized and modelled (using logistic regressions and Gompertz functions), in order to describe wood phenology and intra-annual dynamics of tree-ring formation. We believe that CAVIAR will help strengthening the science of wood formation dynamics by effectively contributing to the standardization of its concepts and methods, making thereby possible the comparison between data and results from different studies.

  13. In Situ Stem Psychrometry: toward a Physiologically-Based Drought Monitoring Network

    NASA Astrophysics Data System (ADS)

    KOCH, G. W.; Williams, C.; Ambrose, A.

    2012-12-01

    Plant water potential is a synoptic variable that integrates soil and atmospheric moisture stress and interacts with plant-internal factors to regulate gas exchange and determine vulnerability to drought-induced hydraulic dysfunction. Despite its importance, methods for measuring water potential are labor intensive. This limitation reduces measurement frequency, likely causes important transient events to be overlooked, and restricts development of a richer understanding of the impacts of integrated water stress on plant and ecosystem function. Recent technological advances have enabled in-situ, automated measurement of branch water potential over periods of weeks to months using stem psychrometers. We evaluated this technology through laboratory and field comparisons to standard pressure chamber measurements and with field installations in temperate forest, semi-arid woodland, and chaparral ecosystems. Performance was highly sensitive to installation procedures. With proper sealing, insulation, and radiation shielding, psychrometers typically differed from pressure chamber measurements by less than 0.2 MPa down to water potentials as low as -7 MPa. Measurements in tall trees reaffirmed the influence of gravity on water potential as previously documented with the pressure chamber. Psychrometer performance in situ was stable for periods of several weeks to months, with tissue wound response degrading sensor operation over time. We conclude that stem psychrometer technology is now suitable to serve as the foundation for a physiologically-based drought monitoring network that can anticipate important ecosystem impacts including changes in whole-system fluxes and mortality events.

  14. Flexible and wearable electronic silk fabrics for human physiological monitoring

    NASA Astrophysics Data System (ADS)

    Mao, Cuiping; Zhang, Huihui; Lu, Zhisong

    2017-09-01

    The development of textile-based devices for human physiological monitoring has attracted tremendous interest in recent years. However, flexible physiological sensing elements based on silk fabrics have not been realized. In this paper, ZnO nanorod arrays are grown in situ on reduced graphene oxide-coated silk fabrics via a facile electro-deposition method for the fabrication of silk-fabric-based mechanical sensing devices. The data show that well-aligned ZnO nanorods with hexagonal wurtzite crystalline structures are synthesized on the conductive silk fabric surface. After magnetron sputtering of gold electrodes, silk-fabric-based devices are produced and applied to detect periodic bending and twisting. Based on the electric signals, the deformation and release processes can be easily differentiated. Human arterial pulse and respiration can also be real-time monitored to calculate the pulse rate and respiration frequency, respectively. Throat vibrations during coughing and singing are detected to demonstrate the voice recognition capability. This work may not only help develop silk-fabric-based mechanical sensing elements for potential applications in clinical diagnosis, daily healthcare monitoring and voice recognition, but also provide a versatile method for fabricating textile-based flexible electronic devices.

  15. Wearable sensors for human health monitoring

    NASA Astrophysics Data System (ADS)

    Asada, H. Harry; Reisner, Andrew

    2006-03-01

    Wearable sensors for continuous monitoring of vital signs for extended periods of weeks or months are expected to revolutionize healthcare services in the home and workplace as well as in hospitals and nursing homes. This invited paper describes recent research progress in wearable health monitoring technology and its clinical applications, with emphasis on blood pressure and circulatory monitoring. First, a finger ring-type wearable blood pressure sensor based on photo plethysmogram is presented. Technical issues, including motion artifact reduction, power saving, and wearability enhancement, will be addressed. Second, sensor fusion and sensor networking for integrating multiple sensors with diverse modalities will be discussed for comprehensive monitoring and diagnosis of health status. Unlike traditional snap-shot measurements, continuous monitoring with wearable sensors opens up the possibility to treat the physiological system as a dynamical process. This allows us to apply powerful system dynamics and control methodologies, such as adaptive filtering, single- and multi-channel system identification, active noise cancellation, and adaptive control, to the monitoring and treatment of highly complex physiological systems. A few clinical trials illustrate the potentials of the wearable sensor technology for future heath care services.

  16. BeMonitored: Monitoring psychophysiology and behavior using Android in phobias.

    PubMed

    Brás, Susana; Soares, Sandra C; Moreira, Ricardo; Fernandes, José M

    2016-09-01

    It is of the utmost importance that researchers can recreate, as accurately as possible, real-life conditions in psychological studies. However, that is not always possible. Given that phobias are rather context-specific, their study is the ideal candidate to assess the feasibility of using a mobile and wearable device for obtaining physiological and behavioral data. In this article, we propose BeMonitored, a smartphone-based solution to support more ecologically valid monitoring of psychological experiments. BeMonitored delivers customizable, specific context-dependent audiovisual stimuli and uses external resources connected via Bluetooth or a smartphone's own resources, while capturing the participant's behavior, physiology, and environment. We used BeMonitored in a spider phobia case study and showed that spider phobics differed from control participants in face motion, captured by the smartphone camera. Moreover, our results also revealed heart rate differences between spider and neutral stimuli in phobic participants. The presented results emphasize the usefulness of smartphones for phobia monitoring. Considering their intrinsic characteristics, smartphones may constitute the natural evolution from the lab to more realistic contexts.

  17. Microencapsulated fluorescent pH probe as implantable sensor for monitoring the physiological state of fish embryos.

    PubMed

    Gurkov, Anton; Sadovoy, Anton; Shchapova, Ekaterina; Teh, Cathleen; Meglinski, Igor; Timofeyev, Maxim

    2017-01-01

    In vivo physiological measurement is a major challenge in modern science and technology, as is environment conservation at the global scale. Proper toxicological testing of widely produced mixtures of chemicals is a necessary step in the development of new products, allowing us to minimize the human impact on aquatic ecosystems. However, currently available bioassay-based techniques utilizing small aquatic organisms such as fish embryos for toxicity testing do not allow assessing in time the changes in physiological parameters in the same individual. In this study, we introduce microencapsulated fluorescent probes as a promising tool for in vivo monitoring of internal pH variation in zebrafish embryos. The pH alteration identified under stress conditions demonstrates the applicability of the microencapsulated fluorescent probes for the repeated analysis of the embryo's physiological state. The proposed approach has strong potential to simultaneously measure a range of physiological characteristics using a set of specific fluorescent probes and to finally bring toxicological bioassays and related research fields to a new level of effectiveness and sensitivity.

  18. An e-caring chair for physiological signal measurement and recording.

    PubMed

    Chang, Hsien-Tsung; Chung, Chyan-Goei; Chen, Ming-Wei

    2013-02-01

    There is an increasing awareness among the populace of the need for regular health check-up to detect diseases in their early stages and thereby administer treatments in a timely fashion. However, commercially available physiological signal monitoring devices, which may offer clues on the onset of diseases, are time-consuming, far from user friendly and limited in their applications. We design an e-caring chair that combines six modular physiological signal measurement instruments into a single unit, enabling users to simultaneously measure the blood pressure, body temperature, heart rate, height, weight and body fat percentage, and display the results and simple diagnoses in real time. The e-caring chair further allows for easy integration of additional physiological signal measuring devices, speedy measurements and long term monitoring of any trends that may emerge, making it easier for users to be alerted to physiological changes in the body without the need to enlist assistance from medical personnel. In this paper, we describe how this e-caring chair can be placed in several different environments for different purposes. Copyright © 2011 IPEM. Published by Elsevier Ltd. All rights reserved.

  19. Impact of Missing Physiologic Data on Performance of the Simplified Acute Physiology Score 3 Risk-Prediction Model.

    PubMed

    Engerström, Lars; Nolin, Thomas; Mårdh, Caroline; Sjöberg, Folke; Karlström, Göran; Fredrikson, Mats; Walther, Sten M

    2017-12-01

    The Simplified Acute Physiology 3 outcome prediction model has a narrow time window for recording physiologic measurements. Our objective was to examine the prevalence and impact of missing physiologic data on the Simplified Acute Physiology 3 model's performance. Retrospective analysis of prospectively collected data. Sixty-three ICUs in the Swedish Intensive Care Registry. Patients admitted during 2011-2014 (n = 107,310). None. Model performance was analyzed using the area under the receiver operating curve, scaled Brier's score, and standardized mortality rate. We used a recalibrated Simplified Acute Physiology 3 model and examined model performance in the original dataset and in a dataset of complete records where missing data were generated (simulated dataset). One or more data were missing in 40.9% of the admissions, more common in survivors and low-risk admissions than in nonsurvivors and high-risk admissions. Discrimination did not decrease with one to two missing variables, but accuracy was highest with no missing data. Calibration was best in the original dataset with a mix of full records and records with some missing values (area under the receiver operating curve was 0.85, scaled Brier 27%, and standardized mortality rate 0.99). With zero, one, and two data missing, the scaled Brier was 31%, 26%, and 21%; area under the receiver operating curve was 0.84, 0.87, and 0.89; and standardized mortality rate was 0.92, 1.05 and 1.10, respectively. Datasets where the missing data were simulated for oxygenation or oxygenation and hydrogen ion concentration together performed worse than datasets with these data originally missing. There is a coupling between missing physiologic data, admission type, low risk, and survival. Increased loss of physiologic data reduced model performance and will deflate mortality risk, resulting in falsely high standardized mortality rates.

  20. Examining the Relationship Between Mental, Physical, and Organizational Factors Associated With Attrition During Maritime Forces Training.

    PubMed

    Binsch, Olaf; Banko, Katherine M; Veenstra, Bertil J; Valk, Pierre J L

    2015-11-01

    For infantry units of the Dutch Ministry of Defence, high attrition rates (varying from 42 to 68%) during initial training are a persisting problem. The reasons for this attrition are diverse. Having better insight into the causes of attrition is a prerequisite for implementing preventive measures. To achieve this, a monitoring assessment system was developed that integrated the effects of physical, mental, and organizational determinants on operational readiness. The aim of this study was to implement the monitoring tools and to establish the set of determinants that best predicted attrition during infantry training of new recruits. Eighty-five recruits were monitored over a 24-week infantry training course. Before the training, recruits were screened for medical, psychological, and physical wellness. During the monitoring phase, mental, physiological, and organizational indicants were obtained using an array of tools such as questionnaires, chest belt monitors (for heart rate, acceleration, and skin temperature measurements), and computerized tests (e.g., vigilance, long-term memory). Survival analyses were used to tease out the determinants of individual and grouped predictors of attrition. Nearly half the recruits (47%) failed the training. Attrition was predicted by both physiological and mental determinants. However, the organizational determinant "trainers' judgment" on the "recruits' military quality" dominated the physiological and mental determinants. It was concluded that the monitoring system was successfully implemented during infantry training, and that the survival analysis method emphasized on single effects and interactions between the different determinants. Based on the current findings, we recommend several steps to successfully implement a monitoring method in settings with high demands.

  1. In vivo sodium concentration continuously monitored with fluorescent sensors.

    PubMed

    Dubach, J Matthew; Lim, Edward; Zhang, Ning; Francis, Kevin P; Clark, Heather

    2011-02-01

    Sodium balance is vital to maintaining normal physiological function. Imbalances can occur in a variety of diseases, during certain surgical operations or during rigorous exercise. There is currently no method to continuously monitor sodium concentration in patients who may be susceptible to hyponatremia. Our approach was to design sodium specific fluorescent sensors capable of measuring physiological fluctuations in sodium concentration. The sensors are submicron plasticized polymer particles containing sodium recognition components that are coated with biocompatible poly(ethylene) glycol. Here, the sensors were brought up in saline and placed in the subcutaneous area of the skin of mice by simple injection. The fluorescence was monitored in real time using a whole animal imager to track changes in sodium concentrations. This technology could be used to monitor certain disease states or warn against dangerously low levels of sodium during exercise.

  2. Physiology in conservation translocations

    PubMed Central

    Tarszisz, Esther; Dickman, Christopher R.; Munn, Adam J.

    2014-01-01

    Conservation translocations aim to restore species to their indigenous ranges, protect populations from threats and/or reinstate ecosystem functions. They are particularly important for the conservation and management of rare and threatened species. Despite tremendous efforts and advancement in recent years, animal conservation translocations generally have variable success, and the reasons for this are often uncertain. We suggest that when little is known about the physiology and wellbeing of individuals either before or after release, it will be difficult to determine their likelihood of survival, and this could limit advancements in the science of translocations for conservation. In this regard, we argue that physiology offers novel approaches that could substantially improve translocations and associated practices. As a discipline, it is apparent that physiology may be undervalued, perhaps because of the invasive nature of some physiological measurement techniques (e.g. sampling body fluids, surgical implantation). We examined 232 publications that dealt with translocations of terrestrial vertebrates and aquatic mammals and, defining ‘success’ as high or low, determined how many of these studies explicitly incorporated physiological aspects into their protocols and monitoring. From this review, it is apparent that physiological evaluation before and after animal releases could progress and improve translocation/reintroduction successes. We propose a suite of physiological measures, in addition to animal health indices, for assisting conservation translocations over the short term and also for longer term post-release monitoring. Perhaps most importantly, we argue that the incorporation of physiological assessments of animals at all stages of translocation can have important welfare implications by helping to reduce the total number of animals used. Physiological indicators can also help to refine conservation translocation methods. These approaches fall under a new paradigm that we term ‘translocation physiology’ and represent an important sub-discipline within conservation physiology generally. PMID:27293675

  3. Oximetry: A Reflective Tool for the Detection of Physiological Expression of Emotions in a Science Education Classroom

    ERIC Educational Resources Information Center

    Calderón, Olga

    2016-01-01

    The pulse oximeter is a device that measures the oxygen concentration (or oxygen saturation--SpO[subscript 2]); heart rate, and heartbeat of a person at any given time. This instrument is commonly used in medical and aerospace fields to monitor physiological outputs of a patient according to health conditions or physiological yields of a flying…

  4. The Graphical Representation of the Digital Astronaut Physiology Backbone

    NASA Technical Reports Server (NTRS)

    Briers, Demarcus

    2010-01-01

    This report summarizes my internship project with the NASA Digital Astronaut Project to analyze the Digital Astronaut (DA) physiology backbone model. The Digital Astronaut Project (DAP) applies integrated physiology models to support space biomedical operations, and to assist NASA researchers in closing knowledge gaps related to human physiologic responses to space flight. The DA physiology backbone is a set of integrated physiological equations and functions that model the interacting systems of the human body. The current release of the model is HumMod (Human Model) version 1.5 and was developed over forty years at the University of Mississippi Medical Center (UMMC). The physiology equations and functions are scripted in an XML schema specifically designed for physiology modeling by Dr. Thomas G. Coleman at UMMC. Currently it is difficult to examine the physiology backbone without being knowledgeable of the XML schema. While investigating and documenting the tags and algorithms used in the XML schema, I proposed a standard methodology for a graphical representation. This standard methodology may be used to transcribe graphical representations from the DA physiology backbone. In turn, the graphical representations can allow examination of the physiological functions and equations without the need to be familiar with the computer programming languages or markup languages used by DA modeling software.

  5. Hyperpolarized 15N-pyridine Derivatives as pH-Sensitive MRI Agents

    PubMed Central

    Jiang, Weina; Lumata, Lloyd; Chen, Wei; Zhang, Shanrong; Kovacs, Zoltan; Sherry, A. Dean; Khemtong, Chalermchai

    2015-01-01

    Highly sensitive MR imaging agents that can accurately and rapidly monitor changes in pH would have diagnostic and prognostic value for many diseases. Here, we report an investigation of hyperpolarized 15N-pyridine derivatives as ultrasensitive pH-sensitive imaging probes. These molecules are easily polarized to high levels using standard dynamic nuclear polarization (DNP) techniques and their 15N chemical shifts were found to be highly sensitive to pH. These probes displayed sharp 15N resonances and large differences in chemical shifts (Δδ >90 ppm) between their free base and protonated forms. These favorable features make these agents highly suitable candidates for the detection of small changes in tissue pH near physiological values. PMID:25774436

  6. Metabolic and physiologic responses to video game play in 7- to 10-year-old boys.

    PubMed

    Wang, Xuewen; Perry, Arlette C

    2006-04-01

    To examine the metabolic, physiologic, and hemostatic responses to action video game play in a group of young boys. Comparison study. Laboratory of Clinical and Applied Physiology, University of Miami. Twenty-one boys aged 7 to 10 years. Blood pressure monitored before and during game play and blood glucose and lactate levels measured before and immediately after game play. Measurements were continuously recorded throughout game play. Dependent t tests were used to compare measurements recorded at baseline and during or after game play. Effect sizes using the Cohen d were examined for comparisons. Significant increases from baseline were found for heart rate (18.8%; P<.001), systolic (22.3%; P<.001) and diastolic (5.8%; P = .006) blood pressure, ventilation (51.9%; P<.001), respiratory rate (54.8%; P<.001), oxygen consumption (49.0%; P<.001), and energy expenditure (52.9%; P<.001). Effect sizes for these comparisons were medium or large. No significant changes were found from baseline to after video game play for lactate (18.2% increase; P = .07) and glucose (0.9% decrease; P = .59) levels. Video game play results in significant increases in various metabolic and physiologic variables in young children. Thus, it should not be combined with television viewing for the evaluation of sedentary activities. The magnitude of change, however, was lower than that observed during standard physical exercise and below national health recommendations. As such, video game play should not be considered a substitute for regular physical activities that significantly stress the metabolic pathways required for the promotion of cardiovascular conditioning.

  7. Infrasonic Stethoscope for Monitoring Physiological Processes

    NASA Technical Reports Server (NTRS)

    Zuckerwar, Allan J. (Inventor); Shams, Qamar A. (Inventor); Dimarcantonio, Albert L. (Inventor)

    2018-01-01

    An infrasonic stethoscope for monitoring physiological processes of a patient includes a microphone capable of detecting acoustic signals in the audible frequency bandwidth and in the infrasonic bandwidth (0.03 to 1000 Hertz), a body coupler attached to the body at a first opening in the microphone, a flexible tube attached to the body at a second opening in the microphone, and an earpiece attached to the flexible tube. The body coupler is capable of engagement with a patient to transmit sounds from the person, to the microphone and then to the earpiece.

  8. Infrasonic Stethoscope for Monitoring Physiological Processes

    NASA Technical Reports Server (NTRS)

    Zuckerwar, Allan J. (Inventor); Shams, Qamar A. (Inventor); Dimarcantonio, Albert L. (Inventor)

    2016-01-01

    An infrasonic stethoscope for monitoring physiological processes of a patient includes a microphone capable of detecting acoustic signals in the audible frequency bandwidth and in the infrasonic bandwidth (0.03 to 1000 Hertz), a body coupler attached to the body at a first opening in the microphone, a flexible tube attached to the body at a second opening in the microphone, and an earpiece attached to the flexible tube. The body coupler is capable of engagement with a patient to transmit sounds from the person, to the microphone and then to the earpiece.

  9. Comparative analysis of international standards for the fatigue testing of posterior spinal fixation systems.

    PubMed

    Villa, Tomaso; La Barbera, Luigi; Galbusera, Fabio

    2014-04-01

    Preclinical evaluation of the long-term reliability of devices for lumbar fixation is a mandatory activity before they are put into market. The experimental setups are described in two different standards edited by the International Organization for Standardization (ISO) and the American Society for Testing Materials (ASTM), but the evaluation of the suitability of such tests to simulate the actual loading with in vivo situations has never been performed. To calculate through finite element (FE) simulations the stress in the rods of the fixator when subjected to ASTM and ISO standards. To compare the calculated stresses arising in the same fixator once it has been virtually mounted in a physiological environment and loaded with physiological forces and moments. FE simulations and validation experimental tests. FE models of the ISO and ASTM setups were created to conduct simulations of the tests prescribed by standards and calculate stresses in the rods. Validation of the simulations were performed through experimental tests; the same fixator was virtually mounted in an L2-L4 FE model of the lumbar spine and stresses in the rods were calculated when the spine was subjected to physiological forces and moments. The comparison between FE simulations and experimental tests showed good agreement between results obtained using the two methodologies, thus confirming the suitability of the FE method to evaluate stresses in the device in different loading situations. The usage of a physiological load with ASTM standard is impossible due to the extreme severity of the ASTM configuration; in this circumstance, the presence of an anterior support is suggested. Also, ISO prescriptions, although the choice of the setup correctly simulates the mechanical contribution of the discs, seem to overstress the device as compared with a physiological loading condition. Some daily activities, other than walking, can induce a further state of stress in the device that should be taken into account in setting up new experimental procedures. ISO standard loading prescriptions seems to be more severe than the expected physiological ones. The ASTM standard should be completed by including some anterior supporting device and declaring the value of the load to be imposed. Moreover, a further enhancement of standards would be simulating other movements representative of daily activities different from walking. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. An adaptive Kalman filter technique for context-aware heart rate monitoring.

    PubMed

    Xu, Min; Goldfain, Albert; Dellostritto, Jim; Iyengar, Satish

    2012-01-01

    Traditional physiological monitoring systems convert a person's vital sign waveforms, such as heart rate, respiration rate and blood pressure, into meaningful information by comparing the instant reading with a preset threshold or a baseline without considering the contextual information of the person. It would be beneficial to incorporate the contextual data such as activity status of the person to the physiological data in order to obtain a more accurate representation of a person's physiological status. In this paper, we proposed an algorithm based on adaptive Kalman filter that describes the heart rate response with respect to different activity levels. It is towards our final goal of intelligent detection of any abnormality in the person's vital signs. Experimental results are provided to demonstrate the feasibility of the algorithm.

  11. Sub-micron opto-chemical probes for studying living neurons

    NASA Astrophysics Data System (ADS)

    Hossein-Zadeh, M.; Delgado, J.; Schweizer, F.; Lieberman, R.

    2017-02-01

    We have fabricated sub-micron opto-chemical probes for pH, oxygen and calcium monitoring and demonstrated their application in intracellular and extracellular monitoring of neurons (cortical neuronal cultures and acute hippocampal slices). Using these probes, we have measured extracellular pH in the stratum radiatum of the CA1 region of mouse hippocampus upon stimulation of presynaptic Schaffer collateral axons. Synaptic transmission was monitored using standard electrophysiological techniques. We find that the local pH transiently changes in response to synaptic stimulation. In addition, the geometry of the functionalized region on the probe combined with high sensitivity imaging enables simultaneous monitoring of spatially adjacent but distinct compartments. As proof of concept we impaled cultured neurons with the probe measured calcium and pH inside as well as directly outside of neurons as we changed the pH and calcium concentration in the physiological solution in the perfusion chamber. As such these probes can be used to study the impact of the environment on both cellular and extra-cellular space. Additionally as the chemical properties of the surrounding medium can be controlled and monitored with high precision, these probes enable differential measurement of the target parameter referenced to a stable bath. This approach eliminates the uncertainties associated with non-chemical fluctuations in the fluorescent emission and result in a self-calibrated opto-chemical probe. We have also demonstrated multifunctional probes that are capable of measuring up to three parameters in the extracellular space in brain slices.

  12. Monitoring pulmonary function with superimposed pulmonary gas exchange curves from standard analyzers.

    PubMed

    Zar, Harvey A; Noe, Frances E; Szalados, James E; Goodrich, Michael D; Busby, Michael G

    2002-01-01

    A repetitive graphic display of the single breath pulmonary function can indicate changes in cardiac and pulmonary physiology brought on by clinical events. Parallel advances in computer technology and monitoring make real-time, single breath pulmonary function clinically practicable. We describe a system built from a commercially available airway gas monitor and off the shelf computer and data-acquisition hardware. Analog data for gas flow rate, O2, and CO2 concentrations are introduced into a computer through an analog-to-digital conversion board. Oxygen uptake (VO2) and carbon dioxide output (VCO2) are calculated for each breath. Inspired minus expired concentrations for O2 and CO2 are displayed simultaneously with the expired gas flow rate curve for each breath. Dead-space and alveolar ventilation are calculated for each breath and readily appreciated from the display. Graphs illustrating the function of the system are presented for the following clinical scenarios; upper airway obstruction, bronchospasm, bronchopleural fistula, pulmonary perfusion changes and inadequate oxygen delivery. This paper describes a real-time, single breath pulmonary monitoring system that displays three parameters graphed against time: expired flow rate, oxygen uptake and carbon dioxide production. This system allows for early and rapid recognition of treatable conditions that may lead to adverse events without any additional patient measurements or invasive procedures. Monitoring systems similar to the one described in this paper may lead to a higher level of patient safety without any additional patient risk.

  13. Advanced integrated real-time clinical displays.

    PubMed

    Kruger, Grant H; Tremper, Kevin K

    2011-09-01

    Intelligent medical displays have the potential to improve patient outcomes by integrating multiple physiologic signals, exhibiting high sensitivity and specificity, and reducing information overload for physicians. Research findings have suggested that information overload and distractions caused by patient care activities and alarms generated by multiple monitors in acute care situations, such as the operating room and the intensive care unit, may produce situations that negatively impact the outcomes of patients under anesthesia. This can be attributed to shortcomings of human-in-the-loop monitoring and the poor specificity of existing physiologic alarms. Modern artificial intelligence techniques (ie, intelligent software agents) are demonstrating the potential to meet the challenges of next-generation patient monitoring and alerting. Copyright © 2011 Elsevier Inc. All rights reserved.

  14. 21 CFR 870.2910 - Radiofrequency physiological signal transmitter and receiver.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Radiofrequency physiological signal transmitter and receiver. 870.2910 Section 870.2910 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring...

  15. 21 CFR 870.2910 - Radiofrequency physiological signal transmitter and receiver.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiofrequency physiological signal transmitter and receiver. 870.2910 Section 870.2910 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring...

  16. Systems identification and application systems development for monitoring the physiological and health status of crewmen in space

    NASA Technical Reports Server (NTRS)

    Leonard, J. I.; Furukawa, S.; Vannordstrand, P. C.

    1975-01-01

    The use of automated, analytical techniques to aid medical support teams is suggested. Recommendations are presented for characterizing crew health in terms of: (1) wholebody function including physiological, psychological and performance factors; (2) a combination of critical performance indexes which consist of multiple factors of measurable parameters; (3) specific responses to low noise level stress tests; and (4) probabilities of future performance based on present and periodic examination of past performance. A concept is proposed for a computerized real time biomedical monitoring and health care system that would have the capability to integrate monitored data, detect off-nominal conditions based on current knowledge of spaceflight responses, predict future health status, and assist in diagnosis and alternative therapies. Mathematical models could play an important role in this approach, especially when operating in a real time mode. Recommendations are presented to update the present health monitoring systems in terms of recent advances in computer technology and biomedical monitoring systems.

  17. 40 CFR 468.03 - Monitoring and reporting requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... monitoring procedure for TTO, indirect dischargers may monitor for oil and grease and meet the alternate monitoring standards for oil and grease established for PSES and PSNS. Any indirect discharger meeting the alternate monitoring oil and grease standards shall be considered to meet the TTO standard. ...

  18. 40 CFR 468.03 - Monitoring and reporting requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... monitoring procedure for TTO, indirect dischargers may monitor for oil and grease and meet the alternate monitoring standards for oil and grease established for PSES and PSNS. Any indirect discharger meeting the alternate monitoring oil and grease standards shall be considered to meet the TTO standard. ...

  19. 40 CFR 468.03 - Monitoring and reporting requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... monitoring procedure for TTO, indirect dischargers may monitor for oil and grease and meet the alternate monitoring standards for oil and grease established for PSES and PSNS. Any indirect discharger meeting the alternate monitoring oil and grease standards shall be considered to meet the TTO standard. ...

  20. 40 CFR 468.03 - Monitoring and reporting requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... monitoring procedure for TTO, indirect dischargers may monitor for oil and grease and meet the alternate monitoring standards for oil and grease established for PSES and PSNS. Any indirect discharger meeting the alternate monitoring oil and grease standards shall be considered to meet the TTO standard. ...

  1. Testing the Hip Abductor Muscle Strength of Older Persons Using a Handheld Dynamometer.

    PubMed

    Awwad, Daniel H; Buckley, Jonathan D; Thomson, Rebecca L; O'Connor, Matthew; Carbone, Tania A; Chehade, Mellick J

    2017-09-01

    To investigate the reliability of a clinically applicable method of dynamometry to assess and monitor hip abductor muscle strength in older persons. Bilateral isometric hip abductor muscle strength measured with a handheld dynamometer, patients supine with the contralateral hip positioned directly against a wall for stabilization. Reliability determined by comparing intra-assessor and inter-assessor results and comparison to a criterion standard (stabilized dynamometer with patients in the standing position). UniSA Nutritional Physiology Research Centre. Twenty-one patients older than 65 years were recruited from the Royal Adelaide Hospital. Intraclass correlation coefficients (ICCs), bias, and limits of agreement calculated to determine reliability. Intra-assessor and inter-assessor ICCs were high (0.94 and 0.92-0.94, respectively). There was no intra-assessor bias and narrow limits of agreement (±2.4%). There was a small inter-assessor bias but narrow limits of agreement (0.6%-0.9% and ± 2.3%, respectively). There was a wide variation comparing results to the criterion standard (±5.0%-5.2% limits of agreement), highlighting problems attributed to difficulties that the test population had with the standing position used in the criterion standard test. Testing older persons' hip abductor muscle strength while in the supine position with optimal pelvic stabilization using a handheld dynamometer is highly reliable. While further studies must be done to assess patients with specific pathologies, this test has potential application to monitor and evaluate the effects of surgical interventions and/or rehabilitation protocols for a variety of conditions affecting hip abductor function such as hip fractures and arthritis.

  2. 21 CFR 884.2660 - Fetal ultrasonic monitor and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Fetal ultrasonic monitor and accessories. 884.2660 Section 884.2660 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... physiological condition or characteristic in a measured value over a period of time (e.g., perinatal monitoring...

  3. Monitoring thioredoxin redox with a genetically encoded red fluorescent biosensor.

    PubMed

    Fan, Yichong; Makar, Merna; Wang, Michael X; Ai, Hui-Wang

    2017-09-01

    Thioredoxin (Trx) is one of the two major thiol antioxidants, playing essential roles in redox homeostasis and signaling. Despite its importance, there is a lack of methods for monitoring Trx redox dynamics in live cells, hindering a better understanding of physiological and pathological roles of the Trx redox system. In this work, we developed the first genetically encoded fluorescent biosensor for Trx redox by engineering a redox relay between the active-site cysteines of human Trx1 and rxRFP1, a redox-sensitive red fluorescent protein. We used the resultant biosensor-TrxRFP1-to selectively monitor perturbations of Trx redox in various mammalian cell lines. We subcellularly localized TrxRFP1 to image compartmentalized Trx redox changes. We further combined TrxRFP1 with a green fluorescent Grx1-roGFP2 biosensor to simultaneously monitor Trx and glutathione redox dynamics in live cells in response to chemical and physiologically relevant stimuli.

  4. Developing psychophysiological profiles for monitoring stress

    NASA Astrophysics Data System (ADS)

    Moldow, Roberta L.; Bergen, Michael T.; Belin, Kari; Bululu, Luba; Couso, Olivita; McLaughlin, Joselyn; Short, Kenneth R.; Servatius, Richard J.

    2006-05-01

    Training prepares first responders for disasters including terrorist attacks. To train effectively it should be as realistic as possible and elicit the stress response. We are developing a profile that will be a marker for intensity of stress as well as differentiate stress from exertion. We have monitored stress during several training scenarios for different groups including civilian SWAT teams and the military. In addition, we can monitor stress to exposure to nonlethal weapons. We have monitored stress during exposure to blunt impact using a paintball paradigm. We have measured salivary substances (such as cortisol and DHEA [markers for the hypothalamic-pituitary-adrenal axis]) and amylase [marker for the sympathetic branch of the autonomic nervous system], physiological parameters (such as activity and heart rate), and neuropsychological assessment tools (such as Borg's perceived exertion scale, Spielberger's STAI and Thayer's ADC). With these neuroendocrine, physiological and behavioral indices in hand, we are poised to examine stress induction in preparedness in trainees.

  5. Home medical monitoring network based on embedded technology

    NASA Astrophysics Data System (ADS)

    Liu, Guozhong; Deng, Wenyi; Yan, Bixi; Lv, Naiguang

    2006-11-01

    Remote medical monitoring network for long-term monitoring of physiological variables would be helpful for recovery of patients as people are monitored at more comfortable conditions. Furthermore, long-term monitoring would be beneficial to investigate slowly developing deterioration in wellness status of a subject and provide medical treatment as soon as possible. The home monitor runs on an embedded microcomputer Rabbit3000 and interfaces with different medical monitoring module through serial ports. The network based on asymmetric digital subscriber line (ADSL) or local area network (LAN) is established and a client - server model, each embedded home medical monitor is client and the monitoring center is the server, is applied to the system design. The client is able to provide its information to the server when client's request of connection to the server is permitted. The monitoring center focuses on the management of the communications, the acquisition of medical data, and the visualization and analysis of the data, etc. Diagnosing model of sleep apnea syndrome is built basing on ECG, heart rate, respiration wave, blood pressure, oxygen saturation, air temperature of mouth cavity or nasal cavity, so sleep status can be analyzed by physiological data acquired as people in sleep. Remote medical monitoring network based on embedded micro Internetworking technology have advantages of lower price, convenience and feasibility, which have been tested by the prototype.

  6. Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis.

    PubMed

    Gao, Wei; Emaminejad, Sam; Nyein, Hnin Yin Yin; Challa, Samyuktha; Chen, Kevin; Peck, Austin; Fahad, Hossain M; Ota, Hiroki; Shiraki, Hiroshi; Kiriya, Daisuke; Lien, Der-Hsien; Brooks, George A; Davis, Ronald W; Javey, Ali

    2016-01-28

    Wearable sensor technologies are essential to the realization of personalized medicine through continuously monitoring an individual's state of health. Sampling human sweat, which is rich in physiological information, could enable non-invasive monitoring. Previously reported sweat-based and other non-invasive biosensors either can only monitor a single analyte at a time or lack on-site signal processing circuitry and sensor calibration mechanisms for accurate analysis of the physiological state. Given the complexity of sweat secretion, simultaneous and multiplexed screening of target biomarkers is critical and requires full system integration to ensure the accuracy of measurements. Here we present a mechanically flexible and fully integrated (that is, no external analysis is needed) sensor array for multiplexed in situ perspiration analysis, which simultaneously and selectively measures sweat metabolites (such as glucose and lactate) and electrolytes (such as sodium and potassium ions), as well as the skin temperature (to calibrate the response of the sensors). Our work bridges the technological gap between signal transduction, conditioning (amplification and filtering), processing and wireless transmission in wearable biosensors by merging plastic-based sensors that interface with the skin with silicon integrated circuits consolidated on a flexible circuit board for complex signal processing. This application could not have been realized using either of these technologies alone owing to their respective inherent limitations. The wearable system is used to measure the detailed sweat profile of human subjects engaged in prolonged indoor and outdoor physical activities, and to make a real-time assessment of the physiological state of the subjects. This platform enables a wide range of personalized diagnostic and physiological monitoring applications.

  7. Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis

    NASA Astrophysics Data System (ADS)

    Gao, Wei; Emaminejad, Sam; Nyein, Hnin Yin Yin; Challa, Samyuktha; Chen, Kevin; Peck, Austin; Fahad, Hossain M.; Ota, Hiroki; Shiraki, Hiroshi; Kiriya, Daisuke; Lien, Der-Hsien; Brooks, George A.; Davis, Ronald W.; Javey, Ali

    2016-01-01

    Wearable sensor technologies are essential to the realization of personalized medicine through continuously monitoring an individual’s state of health. Sampling human sweat, which is rich in physiological information, could enable non-invasive monitoring. Previously reported sweat-based and other non-invasive biosensors either can only monitor a single analyte at a time or lack on-site signal processing circuitry and sensor calibration mechanisms for accurate analysis of the physiological state. Given the complexity of sweat secretion, simultaneous and multiplexed screening of target biomarkers is critical and requires full system integration to ensure the accuracy of measurements. Here we present a mechanically flexible and fully integrated (that is, no external analysis is needed) sensor array for multiplexed in situ perspiration analysis, which simultaneously and selectively measures sweat metabolites (such as glucose and lactate) and electrolytes (such as sodium and potassium ions), as well as the skin temperature (to calibrate the response of the sensors). Our work bridges the technological gap between signal transduction, conditioning (amplification and filtering), processing and wireless transmission in wearable biosensors by merging plastic-based sensors that interface with the skin with silicon integrated circuits consolidated on a flexible circuit board for complex signal processing. This application could not have been realized using either of these technologies alone owing to their respective inherent limitations. The wearable system is used to measure the detailed sweat profile of human subjects engaged in prolonged indoor and outdoor physical activities, and to make a real-time assessment of the physiological state of the subjects. This platform enables a wide range of personalized diagnostic and physiological monitoring applications.

  8. Advancements in remote physiological measurement and applications in human-computer interaction

    NASA Astrophysics Data System (ADS)

    McDuff, Daniel

    2017-04-01

    Physiological signals are important for tracking health and emotional states. Imaging photoplethysmography (iPPG) is a set of techniques for remotely recovering cardio-pulmonary signals from video of the human body. Advances in iPPG methods over the past decade combined with the ubiquity of digital cameras presents the possibility for many new, lowcost applications of physiological monitoring. This talk will highlight methods for recovering physiological signals, work characterizing the impact of video parameters and hardware on these measurements, and applications of this technology in human-computer interfaces.

  9. Validity of Wearable Activity Monitors during Cycling and Resistance Exercise.

    PubMed

    Boudreaux, Benjamin D; Hebert, Edward P; Hollander, Daniel B; Williams, Brian M; Cormier, Corinne L; Naquin, Mildred R; Gillan, Wynn W; Gusew, Emily E; Kraemer, Robert R

    2018-03-01

    The use of wearable activity monitors has seen rapid growth; however, the mode and intensity of exercise could affect the validity of heart rate (HR) and caloric (energy) expenditure (EE) readings. There is a lack of data regarding the validity of wearable activity monitors during graded cycling regimen and a standard resistance exercise. The present study determined the validity of eight monitors for HR compared with an ECG and seven monitors for EE compared with a metabolic analyzer during graded cycling and resistance exercise. Fifty subjects (28 women, 22 men) completed separate trials of graded cycling and three sets of four resistance exercises at a 10-repetition-maximum load. Monitors included the following: Apple Watch Series 2, Fitbit Blaze, Fitbit Charge 2, Polar H7, Polar A360, Garmin Vivosmart HR, TomTom Touch, and Bose SoundSport Pulse (BSP) headphones. HR was recorded after each cycling intensity and after each resistance exercise set. EE was recorded after both protocols. Validity was established as having a mean absolute percent error (MAPE) value of ≤10%. The Polar H7 and BSP were valid during both exercise modes (cycling: MAPE = 6.87%, R = 0.79; resistance exercise: MAPE = 6.31%, R = 0.83). During cycling, the Apple Watch Series 2 revealed the greatest HR validity (MAPE = 4.14%, R = 0.80). The BSP revealed the greatest HR accuracy during resistance exercise (MAPE = 6.24%, R = 0.86). Across all devices, as exercise intensity increased, there was greater underestimation of HR. No device was valid for EE during cycling or resistance exercise. HR from wearable devices differed at different exercise intensities; EE estimates from wearable devices were inaccurate. Wearable devices are not medical devices, and users should be cautious when using these devices for monitoring physiological responses to exercise.

  10. Procedures of Exercise Physiology Laboratories

    NASA Technical Reports Server (NTRS)

    Bishop, Phillip A.; Fortney, Suzanne; Greenisen, Michael; Siconolfi, Steven F.; Bamman, Marcas M.; Moore, Alan D., Jr.; Squires, William

    1998-01-01

    This manual describes the laboratory methods used to collect flight crew physiological performance data at the Johnson Space Center. The Exercise Countermeasures Project Laboratory is a standard physiology laboratory; only the application to the study of human physiological adaptations to spaceflight is unique. In the absence of any other recently published laboratory manual, this manual should be a useful document staffs and students of other laboratories.

  11. Study of sleeping in a chemical protective ensemble in a warfare environment. Final report 26 Aug 81-2 Dec 82

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cacioppo, G.M.; Annis, J.F.

    1982-12-01

    Experiments were performed to evaluate the quality of sleep experienced by individuals wearing different chemical protective ensembles (CPE). A series of seven experiments were conducted in which two test subjects slept overnight in an environmentally controlled room while wearing either pajamas (control ensemble) or one of three different CPEs. The three CPEs tested were: the standard West German ground crew ensemble, an ensemble comprised of a combination of equipment of which the Canadian chemical protective coverall was the principal item of clothing, and the U.S. Army standard ground crew ensemble Body temperatures, sleep records, and other physiological measurements were monitoredmore » overnight and form the basis of the objective evaluation. Subjective data were collected by an experiment monitor who kept the test participants under constant observation. Additionally, the participants were required to complete a standard debriefing questionnaire form each post-experiment morning. Because of the limited scope of the experiment, statistical analysis was not appropriate. However, both the objective and subjective data reflected consistent trends and allow confidence in the assessment that current U.S. and NATO CPE combinations provide for adequate sleep quality.« less

  12. Physiological monitoring and analysis of a manned stratospheric balloon test program.

    PubMed

    Garbino, Alejandro; Blue, Rebecca S; Pattarini, James M; Law, Jennifer; Clark, Jonathan B

    2014-02-01

    The Red Bull Stratos Project consisted of incremental high altitude parachute jumps [maximum altitude 127,852 ft (38,969 m)] from a pressurized capsule suspended from a stratospheric helium-filled balloon. A physiological monitoring system was worn by the parachutist to provide operational medical and acceleration data and to record a unique set of data in a supersonic environment. Various physiological parameters, including heart rate (HR), respiratory rate (RR), skin temperature, and triaxial acceleration, were collected during the ascent, high altitude float, free fall, and parachute opening and descent stages of multiple low- and high altitude jumps. Physiologic data were synchronized with global positioning system (GPS) and audiovisual data for a comprehensive understanding of the environmental stressors experienced. HR reached maximum during capsule egress and remained elevated throughout free fall and landing. RR reached its maximum during free fall. Temperature data were unreliable and did not provide useful results. The highest accelerations parameters were recorded during parachute opening and during landing. During each high altitude jump, immediately after capsule egress, the parachutist experienced a few seconds of microgravity during which some instability occurred. Control was regained as the parachutist entered denser atmosphere. The high altitude environment resulted in extremely high vertical speeds due to little air resistance in comparison to lower altitude jumps with similar equipment. The risk for tumbling was highest at initial step-off. Physiological responses included elevated HR and RR throughout critical phases of free fall. The monitoring unit performed well despite the austere environment and extreme human performance activities.

  13. Applying the dual-isotope conceptual model to interpret physiological trends under uncontrolled conditions

    EPA Science Inventory

    The inter-relationships among δ13C and δ18O in tree ring cellulose and ring width have the potential to illuminate long-term physiological and environmental information in forest stands that have not been monitored. We examine how within-stand competition and environmental gradie...

  14. Automated Guidance from Physiological Sensing to Reduce Thermal-Work Strain Levels on a Novel Task

    USDA-ARS?s Scientific Manuscript database

    This experiment demonstrated that automated pace guidance generated from real-time physiological monitoring allowed least stressful completion of a timed (60 minute limit) 5 mile treadmill exercise. An optimal pacing policy was estimated from a Markov decision process that balanced the goals of the...

  15. PLANT CULTURAL SYSTEM FOR MONITORING EVAPOTRANSPIRATION AND PHYSIOLOGICAL RESPONSES UNDER FIELD CONDITIONS

    EPA Science Inventory

    A plant culture system incorporating the water-table root-screen method for controlling plant water status was adapted for use in open-top field exposure chambers for studying the effects of drought stress on physiological responses. The daily transpiration rates of the plants we...

  16. Wearable Environmental and Physiological Sensing Unit

    NASA Technical Reports Server (NTRS)

    Spremo, Stevan; Ahlman, Jim; Stricker, Ed; Santos, Elmer

    2007-01-01

    The wearable environmental and physiological sensing unit (WEPS) is a prototype of systems to be worn by emergency workers (e.g., firefighters and members of hazardous-material response teams) to increase their level of safety. The WEPS includes sensors that measure a few key physiological and environmental parameters, a microcontroller unit that processes the digitized outputs of the sensors, and a radio transmitter that sends the processed sensor signals to a computer in a mobile command center for monitoring by a supervisor. The monitored parameters serve as real-time indications of the wearer s physical condition and level of activity, and of the degree and type of danger posed by the wearer s environment. The supervisor could use these indications to determine, for example, whether the wearer should withdraw in the face of an increasing hazard or whether the wearer should be rescued.

  17. Measures of rowing performance.

    PubMed

    Smith, T Brett; Hopkins, Will G

    2012-04-01

    Accurate measures of performance are important for assessing competitive athletes in practi~al and research settings. We present here a review of rowing performance measures, focusing on the errors in these measures and the implications for testing rowers. The yardstick for assessing error in a performance measure is the random variation (typical or standard error of measurement) in an elite athlete's competitive performance from race to race: ∼1.0% for time in 2000 m rowing events. There has been little research interest in on-water time trials for assessing rowing performance, owing to logistic difficulties and environmental perturbations in performance time with such tests. Mobile ergometry via instrumented oars or rowlocks should reduce these problems, but the associated errors have not yet been reported. Measurement of boat speed to monitor on-water training performance is common; one device based on global positioning system (GPS) technology contributes negligible extra random error (0.2%) in speed measured over 2000 m, but extra error is substantial (1-10%) with other GPS devices or with an impeller, especially over shorter distances. The problems with on-water testing have led to widespread use of the Concept II rowing ergometer. The standard error of the estimate of on-water 2000 m time predicted by 2000 m ergometer performance was 2.6% and 7.2% in two studies, reflecting different effects of skill, body mass and environment in on-water versus ergometer performance. However, well trained rowers have a typical error in performance time of only ∼0.5% between repeated 2000 m time trials on this ergometer, so such trials are suitable for tracking changes in physiological performance and factors affecting it. Many researchers have used the 2000 m ergometer performance time as a criterion to identify other predictors of rowing performance. Standard errors of the estimate vary widely between studies even for the same predictor, but the lowest errors (~1-2%) have been observed for peak power output in an incremental test, some measures of lactate threshold and measures of 30-second all-out power. Some of these measures also have typical error between repeated tests suitably low for tracking changes. Combining measures via multiple linear regression needs further investigation. In summary, measurement of boat speed, especially with a good GPS device, has adequate precision for monitoring training performance, but adjustment for environmental effects needs to be investigated. Time trials on the Concept II ergometer provide accurate estimates of a rower's physiological ability to output power, and some submaximal and brief maximal ergometer performance measures can be used frequently to monitor changes in this ability. On-water performance measured via instrumented skiffs that determine individual power output may eventually surpass measures derived from the Concept II.

  18. Respiration and heartbeat monitoring using a distributed pulsed MIMO radar.

    PubMed

    Walterscheid, Ingo; Smith, Graeme E

    2017-07-01

    This paper addresses non-contact monitoring of physiological signals induced by respiration and heartbeat. To detect the tiny physiological movements of the chest or other parts of the torso, a Mulitple-Input Multiple-Output (MIMO) radar is used. The spatially distributed transmitters and receivers are able to detect the chest surface movements of one or multiple persons in a room. Due to several bistatic measurements at the same time a robust detection and measuring of the breathing and heartbeat rate is possible. Using an appropriate geometrical configuration of the sensors even a localization of the person is feasible.

  19. Wearable Performance Devices in Sports Medicine.

    PubMed

    Li, Ryan T; Kling, Scott R; Salata, Michael J; Cupp, Sean A; Sheehan, Joseph; Voos, James E

    2016-01-01

    Wearable performance devices and sensors are becoming more readily available to the general population and athletic teams. Advances in technology have allowed individual endurance athletes, sports teams, and physicians to monitor functional movements, workloads, and biometric markers to maximize performance and minimize injury. Movement sensors include pedometers, accelerometers/gyroscopes, and global positioning satellite (GPS) devices. Physiologic sensors include heart rate monitors, sleep monitors, temperature sensors, and integrated sensors. The purpose of this review is to familiarize health care professionals and team physicians with the various available types of wearable sensors, discuss their current utilization, and present future applications in sports medicine. Data were obtained from peer-reviewed literature through a search of the PubMed database. Included studies searched development, outcomes, and validation of wearable performance devices such as GPS, accelerometers, and physiologic monitors in sports. Clinical review. Level 4. Wearable sensors provide a method of monitoring real-time physiologic and movement parameters during training and competitive sports. These parameters can be used to detect position-specific patterns in movement, design more efficient sports-specific training programs for performance optimization, and screen for potential causes of injury. More recent advances in movement sensors have improved accuracy in detecting high-acceleration movements during competitive sports. Wearable devices are valuable instruments for the improvement of sports performance. Evidence for use of these devices in professional sports is still limited. Future developments are needed to establish training protocols using data from wearable devices. © 2015 The Author(s).

  20. Wearable Performance Devices in Sports Medicine

    PubMed Central

    Li, Ryan T.; Kling, Scott R.; Salata, Michael J.; Cupp, Sean A.; Sheehan, Joseph; Voos, James E.

    2016-01-01

    Context: Wearable performance devices and sensors are becoming more readily available to the general population and athletic teams. Advances in technology have allowed individual endurance athletes, sports teams, and physicians to monitor functional movements, workloads, and biometric markers to maximize performance and minimize injury. Movement sensors include pedometers, accelerometers/gyroscopes, and global positioning satellite (GPS) devices. Physiologic sensors include heart rate monitors, sleep monitors, temperature sensors, and integrated sensors. The purpose of this review is to familiarize health care professionals and team physicians with the various available types of wearable sensors, discuss their current utilization, and present future applications in sports medicine. Evidence Acquisition: Data were obtained from peer-reviewed literature through a search of the PubMed database. Included studies searched development, outcomes, and validation of wearable performance devices such as GPS, accelerometers, and physiologic monitors in sports. Study Design: Clinical review. Level of Evidence: Level 4. Results: Wearable sensors provide a method of monitoring real-time physiologic and movement parameters during training and competitive sports. These parameters can be used to detect position-specific patterns in movement, design more efficient sports-specific training programs for performance optimization, and screen for potential causes of injury. More recent advances in movement sensors have improved accuracy in detecting high-acceleration movements during competitive sports. Conclusion: Wearable devices are valuable instruments for the improvement of sports performance. Evidence for use of these devices in professional sports is still limited. Future developments are needed to establish training protocols using data from wearable devices. PMID:26733594

  1. Physiological effects of handling and hauling stress on smallmouth bass

    USGS Publications Warehouse

    Carmichael, G.J.; Wedemeyer, G.A.; McCraren, J.P.; Millard, J.L.

    1983-01-01

    Basic physiological information on the stress caused by current hatchery practices is helpful in developing new and improved techniques to increase survival. In view of the present fishery management requirements for stocking smallmouth bas (Micropterus dolomieu), baseline information on the physiological effects of handling and hauling hatchery-reared fish is needed to serve as the foundation for improving transport methods. Shell (1959) summarized several physiological characteristics of smallmouth bass, but little information on their physiological tolerance to stress exists. The present study was designed to determine the physiological effects of handling and short-term hauling in small mouth bass. Plasma chloride, sodium, potassium, and glucose dynamics were monitored in indicate the severity of the resulting stress and the recovery time needed.

  2. Phun Week: Understanding Physiology

    ERIC Educational Resources Information Center

    Limson, Mel; Matyas, Marsha Lakes

    2009-01-01

    Topics such as sports, exercise, health, and nutrition can make the science of physiology relevant and engaging for students. In addition, many lessons on these topics, such as those on the cardiovascular, respiratory, and digestive systems, align with national and state life science education standards. Physiology Understanding Week (PhUn…

  3. A multimedia perioperative record keeper for clinical research.

    PubMed

    Perrino, A C; Luther, M A; Phillips, D B; Levin, F L

    1996-05-01

    To develop a multimedia perioperative recordkeeper that provides: 1. synchronous, real-time acquisition of multimedia data, 2. on-line access to the patient's chart data, and 3. advanced data analysis capabilities through integrated, multimedia database and analysis applications. To minimize cost and development time, the system design utilized industry standard hardware components and graphical. software development tools. The system was configured to use a Pentium PC complemented with a variety of hardware interfaces to external data sources. These sources included physiologic monitors with data in digital, analog, video, and audio as well as paper-based formats. The development process was guided by trials in over 80 clinical cases and by the critiques from numerous users. As a result of this process, a suite of custom software applications were created to meet the design goals. The Perioperative Data Acquisition application manages data collection from a variety of physiological monitors. The Charter application provides for rapid creation of an electronic medical record from the patient's paper-based chart and investigator's notes. The Multimedia Medical Database application provides a relational database for the organization and management of multimedia data. The Triscreen application provides an integrated data analysis environment with simultaneous, full-motion data display. With recent technological advances in PC power, data acquisition hardware, and software development tools, the clinical researcher now has the ability to collect and examine a more complete perioperative record. It is hoped that the description of the MPR and its development process will assist and encourage others to advance these tools for perioperative research.

  4. Standards, documents of relevance and directives in individual monitoring: is European individual monitoring in compliance with standards?

    PubMed

    Fantuzzi, E

    2007-01-01

    Individual monitoring services (IMS) in Europe do not comply with the same legal or approval requirements. Anyway, a degree of harmonisation existing in individual monitoring practices in Europe has been achieved mainly thanks to documents as standards or international recommendations, which with different weight represent invaluable vehicles of condensed information transfer. However, implementation of standards is not straightforward and harmonisation is not directly a consequence. Somehow, 'harmony' is needed also in standards: IEC and ISO standards, on performance requirements for dosemeters sometimes have different approaches (i.e. performance criteria). Moreover, standards do not all refer to reliability, and therefore being in compliance with standards does not by itself assure that dose results are reliable. Standards are not the only reference documents for an IMS. EURADOS working group on 'Harmonisation of Individual Monitoring in Europe', who has been active in the years 2001-2004, suggested a classification of publication on individual monitoring, distinguishing between standards and documents of relevance, which can be both national and international. None of the two categories are mandatory unless specified in legislation. The Council Directive 96/29/EURATOM and its implementation in each EU Member States has fostered harmonisation of the approach (i.e. approval of dosimetric services) and of the reference quantities for individual monitoring within EU, but national legislation still allow substantial differences in individual monitoring from country to country.

  5. A mobile phone based telemonitoring concept for the simultaneous acquisition of biosignals physiological parameters.

    PubMed

    Kumpusch, Hannes; Hayn, Dieter; Kreiner, Karl; Falgenhauer, Markus; Mor, Jürgen; Schreier, Günter

    2010-01-01

    Congestive Heart Failure (CHF) is a common chronic heart disease with high socioeconomic impact. Conventional treatment of CHF is often ineffective and inefficient, since self-management is complex and patients are insufficiently involved in therapy management. With telemedical concepts, continuous monitoring of the health status can be ensured, and consequently therapy management can be adapted to the individual requirements of every individual patient. Therefore, a mobile phone based patient terminal for the concurrent acquisition of biosignals (e.g. ECG) and bioparameters (e.g. blood pressure) for patients with CHF has been developed and prototypically implemented. Usability and interoperability aspects were especially considered by using Bluetooth and Near Field Communication (NFC) technology for data acquisition and standardized data formats for transmission of the data to a central monitoring centre. Results indicated that even complicated measurements like the acquisition of ECG signals could be accomplished autonomously by the patients in an intuitive and easy-to-use way. Through the usage of IHE conform HL7 messages, self-measured data could easily be integrated into a higher-ranking eHealth infrastructure.

  6. Realising the Potential of Urine and Saliva as Diagnostic Tools in Sport and Exercise Medicine.

    PubMed

    Lindsay, Angus; Costello, Joseph T

    2017-01-01

    Accurate monitoring of homeostatic perturbations following various psychophysiological stressors is essential in sports and exercise medicine. Various biomarkers are routinely used as monitoring tools in both clinical and elite sport settings. Blood collection and muscle biopsies, both invasive in nature, are considered the gold standard for the analysis of these biomarkers in exercise science. Exploring non-invasive methods of collecting and analysing biomarkers that are capable of providing accurate information regarding exercise-induced physiological and psychological stress is of obvious practical importance. This review describes the potential benefits, and the limitations, of using saliva and urine to ascertain biomarkers capable of identifying important stressors that are routinely encountered before, during, or after intense or unaccustomed exercise, competition, over-training, and inappropriate recovery. In particular, we focus on urinary and saliva biomarkers that have previously been used to monitor muscle damage, inflammation, cardiovascular stress, oxidative stress, hydration status, and brain distress. Evidence is provided from a range of empirical studies suggesting that urine and saliva are both capable of identifying various stressors. Although additional research regarding the efficacy of using urine and/or saliva to indicate the severity of exercise-induced psychophysiological stress is required, it is likely that these non-invasive biomarkers will represent "the future" in sports and exercise medicine.

  7. ISFET-based sensor signal processor chip design for environment monitoring applications

    NASA Astrophysics Data System (ADS)

    Chung, Wen-Yaw; Yang, Chung-Huang; Wang, Ming-Ga

    2004-12-01

    In recent years Ion-Sensitive Field Effect Transistor (ISFET) based transducers create valuable applications in physiological data acquisition and environment monitoring. This paper presents a mixed-mode ASIC design for potentiometric ISFET-based bio-chemical sensor applications including H+ sensing and hand-held pH meter. For battery power consideration, the proposed system consists of low voltage (3V) analog front-end readout circuits and digital processor has been developed and fabricated in a 0.5mm double-poly double-metal CMOS technology. To assure that the correct pH value can be measured, the two-point calibration circuitry based on the response of standard pH4 and pH7 buffer solution has been implemented by using algorithmic state machine hardware algorithms. The measurement accuracy of the chip is 10 bits and the measured range between pH 2 to pH 12 compared to ideal values is within the accuracy of 0.1pH. For homeland environmental applications, the system provide rapid, easy to use, and cost-effective on-site testing on the quality of water, such as drinking water, ground water and river water. The processor has a potential usage in battery-operated and portable devices in environmental monitoring applications compared to commercial hand-held pH meter.

  8. Facilities for animal research in space with special reference to Space Station Freedom

    NASA Technical Reports Server (NTRS)

    Bonting, Sjoerd L.; Kishiyama, Jenny S.; Arno, Roger D.

    1990-01-01

    The facilities being planned for animal research on Space Station Freedom are considered in the context of the development of animal habitats from early ballistic and orbital flights to long-term missions aimed at more detailed scientific studies of the effects of space conditions on the vertebrate organism. Animal habitats are becoming more elaborate, requiring systems for environmental control, waste management, physiological monitoring, as well as ancillary facilities such as a 1-G control centrifuge and a glovebox. Habitats in use or to be used in various types of manned and unmanned spacecraft, and particularly those planned for Space Station Freedom, are described. The characteristics of the habitats are compared with each other and with current standards for animal holding facilities on the ground.

  9. Temperature Measurement Inside Protective Headgear: Comparison With Core Temperatures and Indicators of Physiological Strain During Exercise in a Hot Environment.

    PubMed

    Mitchell, Joel B; Goldston, Kelly R; Adams, Amy N; Crisp, Kelli M; Franklin, Brian B; Kreutzer, Andreas; Montalvo, Diego X; Turner, Marcell G; Phillips, Melody D

    2015-01-01

    Non-invasive temperature monitoring with a sensor inside protective headgear may be effective in detecting temperatures that are associated with heat illness. The purpose was to establish the relationship between in-hardhat temperatures (Tih) and core temperature (Tc) as measured by rectal (Tre) and esophageal (Tes) probes. Thirty males (age 24.57 ± 4.32 yrs.) completed two trials: continuous submaximal exercise (CSE) and a series of high intensity 30-s sprints (HIE) with a one-minute rest between each. Exercise in both conditions was in a 36(°)C environment (40% RH) while wearing a standard hardhat with sensors mounted on the forehead that were monitored remotely. Exercise continued until voluntary termination or until Tc reached 39.5(°)C. Temperatures, heart rate, cardiorespiratory, and perceptual responses were monitored throughout. A physiological strain index (PSI) was calculated from Tc and HR. The final temperatures in the CSE condition were 38.77 ± 0.41, 38.90 ± 0.49 and 39.29 ± 0.58(°)C and in the HIE condition, final temperatures were 38.76 ± 0.37, 38.91 ± 0.47, and 39.19 ± 0.57 f (o)C for Tih, Tre, and Tes, respectively. The PSI in CSE was 9.62 ± 062, 9.18 ± 1.11, and 10.04 ± 1.05, and in the HIE condition 9.67 ± 068, 9.29 ± 0.99. and 9.86 ± 1.02 based on Tih, Tre and Tes, respectively. The general agreement between the Tih and other temperature measures along with the consistency as indicated by a low coefficient of variation (approx. 1%) in the recordings of the Tih sensors at the point of termination suggest that this device, or similar devices, may have application as a warning system for impending heat-related problems.

  10. Sex-specific ecophysiological responses to environmental fluctuations of free-ranging Hermann's tortoises: implication for conservation.

    PubMed

    Sibeaux, Adélaïde; Michel, Catherine Louise; Bonnet, Xavier; Caron, Sébastien; Fournière, Kévin; Gagno, Stephane; Ballouard, Jean-Marie

    2016-01-01

    Physiological parameters provide indicators to evaluate how organisms respond to conservation actions. For example, individuals translocated during reinforcement programmes may not adapt to their novel host environment and may exhibit elevated chronic levels of stress hormones and/or decreasing body condition. Conversely, successful conservation actions should be associated with a lack of detrimental physiological perturbation. However, physiological references fluctuate over time and are influenced by various factors (e.g. sex, age, reproductive status). It is therefore necessary to determine the range of natural variations of the selected physiological metrics to establish useful baselines. This study focuses on endangered free-ranging Hermann's tortoises ( Testudo hermanni hermanni ), where conservation actions have been preconized to prevent extinction of French mainland populations. The influence of sex and of environmental factors (site, year and season) on eight physiological parameters (e.g. body condition, corticosterone concentrations) was assessed in 82 individuals from two populations living in different habitats. Daily displacements were monitored by radio-tracking. Most parameters varied between years and seasons and exhibited contrasting sex patterns but with no or limited effect of site. By combining behavioural and physiological traits, this study provides sex-specific seasonal baselines that can be used to monitor the health status of Hermann's tortoises facing environmental threats (e.g. habitat changes) or during conservation actions (e.g. translocation). These results might also assist in selection of the appropriate season for translocation.

  11. Effects of routine handling and tagging procedures on physiological stress responses in juvenile chinook salmon

    USGS Publications Warehouse

    Sharpe, C.S.; Thompson, D.A.; Blankenship, H.L.; Schreck, C.B.

    1998-01-01

    Juvenile chinook salmon Oncorhynchus tshawytscha were subjected to handling and tagging protocols typical of normal hatchery operations and monitored for their physiological response to stress. Treatments included coded-wire-tagging, counting, ventral fin clipping, adipose fin clipping, and a procedure simulating a pond split. Treatment fish were also subjected to a standardized stress challenge (1 h confinement) to evaluate their ability to deal with disturbances subsequent to a handling or tagging procedure. Circulating levels of cortisol and glucose were used as indicators of stress. Each of the treatments elicited very similar responses among treatment groups. Cortisol increased from resting levels of about 20 ng/mL to about 90 ng/mL by 1 h poststress and returned to near resting levels by 8 h poststress. Glucose levels increased from 50 mg/dL to about 80 mg/dL by 1 h poststress and remained elevated for much of the experiment. The cortisol and glucose responses to the confinement stress did not differ over time or among treatments. However, the confinement stress results do suggest a small but significant cumulative response, indicating small residual effects of the original handling protocols. No deaths were noted among treatment groups.

  12. Protein expression changes caused by spaceflight as measured for 18 Russian cosmonauts.

    PubMed

    M Larina, Irina; Percy, Andrew J; Yang, Juncong; Borchers, Christoph H; M Nosovsky, Andrei; I Grigoriev, Anatoli; N Nikolaev, Evgeny

    2017-08-15

    The effects of spaceflight on human physiology is an increasingly studied field, yet the molecular mechanisms driving physiological changes remain unknown. With that in mind, this study was performed to obtain a deeper understanding of changes to the human proteome during space travel, by quantitating a panel of 125 proteins in the blood plasma of 18 Russian cosmonauts who had conducted long-duration missions to the International Space Station. The panel of labeled prototypic tryptic peptides from these proteins covered a concentration range of more than 5 orders of magnitude in human plasma. Quantitation was achieved by a well-established and highly-regarded targeted mass spectrometry approach involving multiple reaction monitoring in conjunction with stable isotope-labeled standards. Linear discriminant function analysis of the quantitative results revealed three distinct groups of proteins: 1) proteins with post-flight protein concentrations remaining stable, 2) proteins whose concentrations recovered slowly, or 3) proteins whose concentrations recovered rapidly to their pre-flight levels. Using a systems biology approach, nearly all of the reacting proteins could be linked to pathways that regulate the activities of proteases, natural immunity, lipid metabolism, coagulation cascades, or extracellular matrix metabolism.

  13. Biomedical Monitoring and Countermeasures Facility

    NASA Technical Reports Server (NTRS)

    Stewart, Donald F.

    1992-01-01

    The Space Station Freedom Program (SSFP) represents the transition within the US Space program from the 'heroic' era of space flight (characterized most vividly by the Mercury and Apollo programs) to an epoch characterized by routine access to the space environment. In this new era, the unique characteristics of the microgravity environment will enable new types of research activities, primarily in the life sciences, materials science, and biotechnology fields. In addition to its role as a'microgravity science laboratory,' Space Station Freedom (SSF) constitutes the operational platform on which the knowledge and skills needed to continue our exploration of space will be acquired. In the area of spacecraft operations, these skills include the ability to assemble, operate, and maintain large structures in space. In the area of crew operations, the potentially harmful effects of extended exposure to microgravity must be understood in order to keep the crew mission capable. To achieve this goal, the complex process of physiological deconditioning must be monitored, and countermeasures utilized as needed to keep the individual crew members within acceptable physiological limits. The countermeasures program under development for the SSF Program is titled the Biomedical Monitoring and Countermeasures (BMAC) program. As implied by the name, this activity has two primary products, a biomedical monitoring element and a countermeasures development effort. The program is a critical path element in the overall SSF Program, and should be considered an essential element of operations on board the space station. It is readily apparent that the capability to both protect and optimize the health and performance of the human operators on board SSF will be a critical element in the overall success of the SSFP. Previous experience within the Russian space program has demonstrated that the time required for countermeasures on extended missions can become a monumental operational burden. Therefore, one of the primary objectives of the countermeasures development activity will be to design and implement countermeasures which are significantly more effective than the existing generation. Other primary objectives include the following: to set health and human performance standards for all mission phases; to determine critical issues that affect performance or return to flight status; to develop and implement monitoring systems to follow health and performance status; and to understand risk, and balance the resource costs of countermeasures vs. the benefit gained.

  14. A Standard Psychophysiological Preparation for Evaluating the Effects of Environmental Vibration Stress. Phase I. Development.

    DTIC Science & Technology

    A Standard Psychophysiological Preparation (SPP) for the evaluation of the physiological and biomechanical mechanisms responsible for performance...consumption, biomechanical parameters and performance level. The results of pilot tests (including 6-hours exposure to vibration while performing a...tracking task) verify the applicability and utility of the SPP and demonstrate that high quality, quantitative physiological and biomechanical data can

  15. Development and application of an antibody-based protein microarray to assess physiological stress in grizzly bears (Ursus arctos).

    PubMed

    Carlson, Ruth I; Cattet, Marc R L; Sarauer, Bryan L; Nielsen, Scott E; Boulanger, John; Stenhouse, Gordon B; Janz, David M

    2016-01-01

    A novel antibody-based protein microarray was developed that simultaneously determines expression of 31 stress-associated proteins in skin samples collected from free-ranging grizzly bears (Ursus arctos) in Alberta, Canada. The microarray determines proteins belonging to four broad functional categories associated with stress physiology: hypothalamic-pituitary-adrenal axis proteins, apoptosis/cell cycle proteins, cellular stress/proteotoxicity proteins and oxidative stress/inflammation proteins. Small skin samples (50-100 mg) were collected from captured bears using biopsy punches. Proteins were isolated and labelled with fluorescent dyes, with labelled protein homogenates loaded onto microarrays to hybridize with antibodies. Relative protein expression was determined by comparison with a pooled standard skin sample. The assay was sensitive, requiring 80 µg of protein per sample to be run in triplicate on the microarray. Intra-array and inter-array coefficients of variation for individual proteins were generally <10 and <15%, respectively. With one exception, there were no significant differences in protein expression among skin samples collected from the neck, forelimb, hindlimb and ear in a subsample of n = 4 bears. This suggests that remotely delivered biopsy darts could be used in future sampling. Using generalized linear mixed models, certain proteins within each functional category demonstrated altered expression with respect to differences in year, season, geographical sampling location within Alberta and bear biological parameters, suggesting that these general variables may influence expression of specific proteins in the microarray. Our goal is to apply the protein microarray as a conservation physiology tool that can detect, evaluate and monitor physiological stress in grizzly bears and other species at risk over time in response to environmental change.

  16. Continuous remote monitoring of COPD patients-justification and explanation of the requirements and a survey of the available technologies.

    PubMed

    Tomasic, Ivan; Tomasic, Nikica; Trobec, Roman; Krpan, Miroslav; Kelava, Tomislav

    2018-04-01

    Remote patient monitoring should reduce mortality rates, improve care, and reduce costs. We present an overview of the available technologies for the remote monitoring of chronic obstructive pulmonary disease (COPD) patients, together with the most important medical information regarding COPD in a language that is adapted for engineers. Our aim is to bridge the gap between the technical and medical worlds and to facilitate and motivate future research in the field. We also present a justification, motivation, and explanation of how to monitor the most important parameters for COPD patients, together with pointers for the challenges that remain. Additionally, we propose and justify the importance of electrocardiograms (ECGs) and the arterial carbon dioxide partial pressure (PaCO 2 ) as two crucial physiological parameters that have not been used so far to any great extent in the monitoring of COPD patients. We cover four possibilities for the remote monitoring of COPD patients: continuous monitoring during normal daily activities for the prediction and early detection of exacerbations and life-threatening events, monitoring during the home treatment of mild exacerbations, monitoring oxygen therapy applications, and monitoring exercise. We also present and discuss the current approaches to decision support at remote locations and list the normal and pathological values/ranges for all the relevant physiological parameters. The paper concludes with our insights into the future developments and remaining challenges for improvements to continuous remote monitoring systems. Graphical abstract ᅟ.

  17. Alamos: An International Collaboration to Provide a Space Based Environmental Monitoring Solution for the Deep Space Network

    NASA Astrophysics Data System (ADS)

    Kennedy, S. O.; Dunn, A.; Lecomte, J.; Buchheim, K.; Johansson, E.; Berger, T.

    2018-02-01

    This abstract proposes the advantages of an externally mounted instrument in support of the human physiology, space biology, and human health and performance key science area. Alamos provides Space-Based Environmental Monitoring capabilities.

  18. Monitoring the wild black bear's reaction to human and environmental stressors

    PubMed Central

    2011-01-01

    Background Bears are among the most physiologically remarkable mammals. They spend half their life in an active state and the other half in a state of dormancy without food or water, and without urinating, defecating, or physical activity, yet can rouse and defend themselves when disturbed. Although important data have been obtained in both captive and wild bears, long-term physiological monitoring of bears has not been possible until the recent advancement of implantable devices. Results Insertable cardiac monitors that were developed for use in human heart patients (Reveal® XT, Medtronic, Inc) were implanted in 15 hibernating bears. Data were recovered from 8, including 2 that were legally shot by hunters. Devices recorded low heart rates (pauses of over 14 seconds) and low respiration rates (1.5 breaths/min) during hibernation, dramatic respiratory sinus arrhythmias in the fall and winter months, and elevated heart rates in summer (up to 214 beats/min (bpm)) and during interactions with hunters (exceeding 250 bpm). The devices documented the first and last day of denning, a period of quiescence in two parturient females after birthing, and extraordinary variation in the amount of activity/day, ranging from 0 (winter) to 1084 minutes (summer). Data showed a transition toward greater nocturnal activity in the fall, preceding hibernation. The data-loggers also provided evidence of the physiological and behavioral responses of bears to our den visits to retrieve the data. Conclusions Annual variations in heart rate and activity have been documented for the first time in wild black bears. This technique has broad applications to wildlife management and physiological research, enabling the impact of environmental stressors from humans, changing seasons, climate change, social interactions and predation to be directly monitored over multiple years. PMID:21849079

  19. Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis

    PubMed Central

    Nyein, Hnin Yin Yin; Challa, Samyuktha; Chen, Kevin; Peck, Austin; Fahad, Hossain M.; Ota, Hiroki; Shiraki, Hiroshi; Kiriya, Daisuke; Lien, Der-Hsien; Brooks, George A.; Davis, Ronald W.; Javey, Ali

    2016-01-01

    Wearable sensor technologies are essential to the realization of personalized medicine through continuously monitoring an individual's state of health1–12. Sampling human sweat, which is rich in physiological information13, could enable non-invasive monitoring. Previously reported sweat-based and other non-invasive biosensors either can only monitor a single analyte at a time or lack on-site signal processing circuitry and sensor calibration mechanisms for accurate analysis of the physiological state14–18. Given the complexity of sweat secretion, simultaneous and multiplexed screening of target biomarkers is critical and requires full system integration to ensure the accuracy of measurements. Here we present a mechanically flexible and fully integrated (that is, no external analysis is needed) sensor array for multiplexed in situ perspiration analysis, which simultaneously and selectively measures sweat metabolites (such as glucose and lactate) and electrolytes (such as sodium and potassium ions), as well as the skin temperature (to calibrate the response of the sensors). Our work bridges the technological gap between signal transduction, conditioning (amplification and filtering), processing and wireless transmission in wearable biosensors by merging plastic-based sensors that interface with the skin with silicon integrated circuits consolidated on a flexible circuit board for complex signal processing. This application could not have been realized using either of these technologies alone owing to their respective inherent limitations. The wearable system is used to measure the detailed sweat profile of human subjects engaged in prolonged indoor and outdoor physical activities, and to make a real-time assessment of the physiological state of the subjects. This platform enables a wide range of personalized diagnostic and physiological monitoring applications. PMID:26819044

  20. A wearable device for emotional recognition using facial expression and physiological response.

    PubMed

    Jangho Kwon; Da-Hye Kim; Wanjoo Park; Laehyun Kim

    2016-08-01

    This paper introduces a glasses-typed wearable system to detect user's emotions using facial expression and physiological responses. The system is designed to acquire facial expression through a built-in camera and physiological responses such as photoplethysmogram (PPG) and electrodermal activity (EDA) in unobtrusive way. We used video clips for induced emotions to test the system suitability in the experiment. The results showed a few meaningful properties that associate emotions with facial expressions and physiological responses captured by the developed wearable device. We expect that this wearable system with a built-in camera and physiological sensors may be a good solution to monitor user's emotional state in daily life.

  1. Wearable Beat-to-Beat Blood Pressure Monitor

    NASA Technical Reports Server (NTRS)

    Lee, Yong Jin

    2015-01-01

    Linea Research Corporation has developed a wearable noninvasive monitor that provides continuous blood pressure and heart rate measurements in extreme environments. Designed to monitor the physiological effects of astronauts' prolonged exposure to reduced-gravity environments as well as the effectiveness of various countermeasures, the device offers wireless connectivity to allow transfer of both real-time and historical data. It can be modified to monitor the health status of astronaut crew members during extravehicular missions.

  2. LabVIEW: a software system for data acquisition, data analysis, and instrument control.

    PubMed

    Kalkman, C J

    1995-01-01

    Computer-based data acquisition systems play an important role in clinical monitoring and in the development of new monitoring tools. LabVIEW (National Instruments, Austin, TX) is a data acquisition and programming environment that allows flexible acquisition and processing of analog and digital data. The main feature that distinguishes LabVIEW from other data acquisition programs is its highly modular graphical programming language, "G," and a large library of mathematical and statistical functions. The advantage of graphical programming is that the code is flexible, reusable, and self-documenting. Subroutines can be saved in a library and reused without modification in other programs. This dramatically reduces development time and enables researchers to develop or modify their own programs. LabVIEW uses a large amount of processing power and computer memory, thus requiring a powerful computer. A large-screen monitor is desirable when developing larger applications. LabVIEW is excellently suited for testing new monitoring paradigms, analysis algorithms, or user interfaces. The typical LabVIEW user is the researcher who wants to develop a new monitoring technique, a set of new (derived) variables by integrating signals from several existing patient monitors, closed-loop control of a physiological variable, or a physiological simulator.

  3. Optical imaging of localized chemical events using programmable diamond quantum nanosensors

    NASA Astrophysics Data System (ADS)

    Rendler, Torsten; Neburkova, Jitka; Zemek, Ondrej; Kotek, Jan; Zappe, Andrea; Chu, Zhiqin; Cigler, Petr; Wrachtrup, Jörg

    2017-03-01

    Development of multifunctional nanoscale sensors working under physiological conditions enables monitoring of intracellular processes that are important for various biological and medical applications. By attaching paramagnetic gadolinium complexes to nanodiamonds (NDs) with nitrogen-vacancy (NV) centres through surface engineering, we developed a hybrid nanoscale sensor that can be adjusted to directly monitor physiological species through a proposed sensing scheme based on NV spin relaxometry. We adopt a single-step method to measure spin relaxation rates enabling time-dependent measurements on changes in pH or redox potential at a submicrometre-length scale in a microfluidic channel that mimics cellular environments. Our experimental data are reproduced by numerical simulations of the NV spin interaction with gadolinium complexes covering the NDs. Considering the versatile engineering options provided by polymer chemistry, the underlying mechanism can be expanded to detect a variety of physiologically relevant species and variables.

  4. DC coupled Doppler radar physiological monitor.

    PubMed

    Zhao, Xi; Song, Chenyan; Lubecke, Victor; Boric-Lubecke, Olga

    2011-01-01

    One of the challenges in Doppler radar systems for physiological monitoring is a large DC offset in baseband outputs. Typically, AC coupling is used to eliminate this DC offset. Since the physiological signals of interest include frequency content near DC, it is not desirable to simply use AC coupling on the radar outputs. While AC coupling effectively removes DC offset, it also introduces a large time delay and distortion. This paper presents the first DC coupled IQ demodulator printed circuit board (PCB) design and measurements. The DC coupling is achieved by using a mixer with high LO to RF port isolation, resulting in a very low radar DC offset on the order of mV. The DC coupled signals from the PCB radar system were successfully detected with significant LNA gain without saturation. Compared to the AC coupled results, the DC coupled results show great advantages of less signal distortion and more accurate rate estimation.

  5. Ultrasonically-Induced Cavitation In Vivo Depends on the Physiological State

    NASA Astrophysics Data System (ADS)

    Vykhodtseva, Natalia I.; Kondrashova, Maria N.

    2006-05-01

    Purpose: To test the hypothesis that the ultrasound-induced cavitation can be facilitated by excitation and stress. Methods: Acoustic emission was monitored from the region of the femoral artery of non-anesthetized rats using a resonant focusing detector (RFD). The RFD consists of two transducers: an inner transmitting transducer (0.87 MHz, R/D=70/28mm), an annular receiving transducer (0.43 MHz, R=70 mm, Dint/Dext=37 /58 mm). Acoustical emission was monitored: (1) during mild immobilization stress (MIS); (2) after strong immobilization stress (SIS); (3) after succinic acid administration (SUC); (4) during negative air-ion inhalation (NAI). Results: The subharmonic emission varied as a function of the physiological states. Both strong immobilization stress and SUC, which increases adrenaline release and stimulates physiological activity of cells, increased cavitation activity. Inhalation of NAI abolished stress-induced cavitation providing a sedative effect.

  6. Microworm optode sensors limit particle diffusion to enable in vivo measurements.

    PubMed

    Ozaydin-Ince, Gozde; Dubach, J Matthew; Gleason, Karen K; Clark, Heather A

    2011-02-15

    There have been a variety of nanoparticles created for in vivo uses ranging from gene and drug delivery to tumor imaging and physiological monitoring. The use of nanoparticles to measure physiological conditions while being fluorescently addressed through the skin provides an ideal method toward minimally invasive health monitoring. Here we create unique particles that have all the necessary physical characteristics to serve as in vivo reporters, but with minimized diffusion from the point of injection. These particles, called microworms, have a cylindrical shape coated with a biocompatible porous membrane that possesses a large surface-area-to-volume ratio while maintaining a large hydrodynamic radius. We use these microworms to create fluorescent sodium sensors for use as in vivo sodium concentration detectors after subcutaneous injection. However, the microworm concept has the potential to extend to the immobilization of other types of polymers for continuous physiological detection or delivery of molecules.

  7. A virtual reality system for neurobehavioral and functional MRI studies.

    PubMed

    Baumann, Stephen; Neff, Chris; Fetzick, Scott; Stangl, Gregg; Basler, Lee; Vereneck, Ray; Schneider, Walter

    2003-06-01

    We are developing a VR system of integrated software and hardware for scientific research and clinical application. The system is sufficiently flexible and broad-based in appeal that neurobehavioral researchers from a variety of disciplines might be interested in using it for basic research and clinical studies. The system runs on a standard Windows-based personal computer with a high-performance graphics card. Options allow a head-mounted display, dataglove, simultaneous physiological monitoring or use within neuroimaging machines such as magnetic resonance imaging (MRI) scanners. Currently, the software consists of a virtual world of nearly a dozen interconnected environments that the subject can freely navigate. Additional environments can be built and easily added to the application. A startup interface provides menus for selecting characters and objects that a researcher might want to put at specific locations within the simulation. Interactivity is provided for many typical objects such as doors, chairs and money. There are more than 50 characters in the world, most of them animated or interactive. All movements and actions of the subject within the world are tracked and recorded to an Excel spreadsheet for data analysis. Overlay maps are available as navigational aids. Concurrent physiological data can be acquired on up to 16 channels. The system provides synchronization of the VR simulation with physiological recordings and functional MR images. A spatial navigation memory task was performed with the integrated VR/fMRI system, and some pilot data is presented that shows robust activation in multiple cortical areas appropriate to the task.

  8. The physiological basis and clinical significance of lung volume measurements.

    PubMed

    Lutfi, Mohamed Faisal

    2017-01-01

    From a physiological standpoint, the lung volumes are either dynamic or static. Both subclasses are measured at different degrees of inspiration or expiration; however, dynamic lung volumes are characteristically dependent on the rate of air flow. The static lung volumes/capacities are further subdivided into four standard volumes (tidal, inspiratory reserve, expiratory reserve, and residual volumes) and four standard capacities (inspiratory, functional residual, vital and total lung capacities). The dynamic lung volumes are mostly derived from vital capacity. While dynamic lung volumes are essential for diagnosis and follow up of obstructive lung diseases, static lung volumes are equally important for evaluation of obstructive as well as restrictive ventilatory defects. This review intends to update the reader with the physiological basis, clinical significance and interpretative approaches of the standard static lung volumes and capacities.

  9. Physiological changes induced in four bacterial strains following oxidative stress.

    PubMed

    Baatout, S; De Boever, P; Mergeay, M

    2006-01-01

    In order to study the behaviour and resistance of bacteria under extreme conditions, physiological changes associated with oxidative stress were monitored using flow cytometry. The study was conducted to assess the maintenance of membrane integrity and potential as well as the esterase activity, the intracellular pH and the production of superoxide anions in four bacterial strains (Ralstonia metallidurans, Escherichia coli, Shewanella oneidensis and Deinococcus radiodurans). The strains were chosen for their potential usefulness in bioremediation. Suspensions of R. metallidurans, E. coli, S. oneidensis and D. radiodurans were submitted to 1 h oxidative stress (H2O2 at various concentrations from 0 to 880 mM). Cell membrane permeability (propidium iodide) and potential (rhodamine-123, 3,3'-dihexyloxacarbocyanine iodide), intracellular esterase activity (fluorescein diacetate), intracellular reactive oxygen species concentration (hydroethidine) and intracellular pH (carboxyflurorescein diacetate succinimidyl ester (5(6)) were monitored to evaluate the physiological state and the overall fitness of individual bacterial cells under oxidative stress. The four bacterial strains exhibited varying sensitivities towards H2O2. However, for all bacterial strains, some physiological damage could already be observed from 13.25 mM H2O2 onwards, in particular with regard to their membrane permeability. Depending on the bacterial strains, moderate to high physiological damage could be observed between 13.25 mM and 220 mM H2O2. Membrane potential, esterase activity, intracellular pH and production of superoxide anion production were considerably modified at high H2O2 concentrations in all four strains. In conclusion, we show that a range of significant physiological alterations occurs when bacteria are challenged with H2O2 and fluorescent staining methods coupled with flow cytometry are useful for monitoring the changes induced not only by oxidative stress but also by other stresses like temperature, radiation, pressure, pH, etc....

  10. Response of Vibrio fischeri to repeated exposures over time in an Online Toxicity Monitor

    EPA Science Inventory

    Online Toxicity Monitors have been developed to provide continuous, time-relevant information regarding water quality. These systems measure a physiological or behavioral response of a sentinel organism to changes water quality. One such system, the Microlan Toxcontrol, is base...

  11. Automated patient monitoring system

    NASA Technical Reports Server (NTRS)

    Bedard, R. E.; Buxton, R. L.; Dawson, W. S.

    1968-01-01

    Radio-linked patient monitoring system collects several channels of physiological data from as many as 64 hospital patients and transmits the data in digital form to a central control station. The system consists of a central control station and battery-operated patient units comprising small strap-on electronics packages.

  12. Development of a brain monitoring system for multimodality investigation in awake rats.

    PubMed

    Limnuson, Kanokwan; Narayan, Raj K; Chiluwal, Amrit; Bouton, Chad; Ping Wang; Chunyan Li

    2016-08-01

    Multimodal brain monitoring is an important approach to gain insight into brain function, modulation, and pathology. We have developed a unique micromachined neural probe capable of real-time continuous monitoring of multiple physiological, biochemical and electrophysiological variables. However, to date, it has only been used in anesthetized animals due to a lack of an appropriate interface for awake animals. We have developed a versatile headstage for recording the small neural signal and bridging the sensors to the remote sensing units for multimodal brain monitoring in awake rats. The developed system has been successfully validated in awake rats by simultaneously measuring four cerebral variables: electrocorticography, oxygen tension, temperature and cerebral blood flow. Reliable signal recordings were obtained with minimal artifacts from movement and environmental noise. For the first time, multiple variables of cerebral function and metabolism were simultaneously recorded from awake rats using a single neural probe. The system is envisioned for studying the effects of pharmacologic treatments, mapping the development of central nervous system diseases, and better understanding normal cerebral physiology.

  13. Mitochondrial flash as a novel biomarker of mitochondrial respiration in the heart.

    PubMed

    Gong, Guohua; Liu, Xiaoyun; Zhang, Huiliang; Sheu, Shey-Shing; Wang, Wang

    2015-10-01

    Mitochondrial respiration through electron transport chain (ETC) activity generates ATP and reactive oxygen species in eukaryotic cells. The modulation of mitochondrial respiration in vivo or under physiological conditions remains elusive largely due to the lack of appropriate approach to monitor ETC activity in a real-time manner. Here, we show that ETC-coupled mitochondrial flash is a novel biomarker for monitoring mitochondrial respiration under pathophysiological conditions in cultured adult cardiac myocyte and perfused beating heart. Through real-time confocal imaging, we follow the frequency of a transient bursting fluorescent signal, named mitochondrial flash, from individual mitochondria within intact cells expressing a mitochondrial matrix-targeted probe, mt-cpYFP (mitochondrial-circularly permuted yellow fluorescent protein). This mt-cpYFP recorded mitochondrial flash has been shown to be composed of a major superoxide signal with a minor alkalization signal within the mitochondrial matrix. Through manipulating physiological substrates for mitochondrial respiration, we find a close coupling between flash frequency and the ETC electron flow, as measured by oxygen consumption rate in cardiac myocyte. Stimulating electron flow under physiological conditions increases flash frequency. On the other hand, partially block or slowdown electron flow by inhibiting the F0F1 ATPase, which represents a pathological condition, transiently increases then decreases flash frequency. Limiting electron entrance at complex I by knocking out Ndufs4, an assembling subunit of complex I, suppresses mitochondrial flash activity. These results suggest that mitochondrial electron flow can be monitored by real-time imaging of mitochondrial flash. The mitochondrial flash frequency could be used as a novel biomarker for mitochondrial respiration under physiological and pathological conditions. Copyright © 2015 the American Physiological Society.

  14. A flexible skin patch for continuous physiological monitoring of mental disorders

    NASA Astrophysics Data System (ADS)

    Jang, Won Ick; Lee, Bong Kuk; Ryu, Jin Hwa; Baek, In-Bok; Yu, Han Young; Kim, Seunghwan

    2017-10-01

    In this study, we have newly developed a flexible adhesive skin patch of electrocardiogram (ECG) device for continuous physiological monitoring of mental disorders. In addition, this flexible patch did not cause any damage to the skin even after 24 hours attachment. We have also suggested the possibility of novel interconnection for copper film on polyimide and polydimethylsiloxane (PDMS) layers of the flexible patch. Self-align and soldering of IC chips such as resistor between metal pads on flexible skin patch have also successfully fabricated for 5 min at 180 °C in vacuum oven. Low temperature interconnection technology based on a Sn42/Bi58 solder was also developed for flexible ECG devices. As a result, we can monitor the mental health status through a comprehensive analysis of biological signals from flexible ECG devices.

  15. Optical Drug Monitoring: Photoacoustic Imaging of Nanosensors to Monitor Therapeutic Lithium In Vivo

    PubMed Central

    Cash, Kevin J.; Li, Chiye; Xia, Jun; Wang, Lihong V.; Clark, Heather A.

    2015-01-01

    Personalized medicine could revolutionize how primary care physicians treat chronic disease and how researchers study fundamental biological questions. To realize this goal we need to develop more robust, modular tools and imaging approaches for in vivo monitoring of analytes. In this report, we demonstrate that synthetic nanosensors can measure physiologic parameters with photoacoustic contrast, and we apply that platform to continuously track lithium levels in vivo. Photoacoustic imaging achieves imaging depths that are unattainable with fluorescence or multiphoton microscopy. We validated the photoacoustic results that illustrate the superior imaging depth and quality of photoacoustic imaging with optical measurements. This powerful combination of techniques will unlock the ability to measure analyte changes in deep tissue and will open up photoacoustic imaging as a diagnostic tool for continuous physiological tracking of a wide range of analytes. PMID:25588028

  16. Optical drug monitoring: photoacoustic imaging of nanosensors to monitor therapeutic lithium in vivo.

    PubMed

    Cash, Kevin J; Li, Chiye; Xia, Jun; Wang, Lihong V; Clark, Heather A

    2015-02-24

    Personalized medicine could revolutionize how primary care physicians treat chronic disease and how researchers study fundamental biological questions. To realize this goal, we need to develop more robust, modular tools and imaging approaches for in vivo monitoring of analytes. In this report, we demonstrate that synthetic nanosensors can measure physiologic parameters with photoacoustic contrast, and we apply that platform to continuously track lithium levels in vivo. Photoacoustic imaging achieves imaging depths that are unattainable with fluorescence or multiphoton microscopy. We validated the photoacoustic results that illustrate the superior imaging depth and quality of photoacoustic imaging with optical measurements. This powerful combination of techniques will unlock the ability to measure analyte changes in deep tissue and will open up photoacoustic imaging as a diagnostic tool for continuous physiological tracking of a wide range of analytes.

  17. Telemetric Sensors for the Space Life Sciences

    NASA Technical Reports Server (NTRS)

    Hines, John W.; Somps, Chris J.; Madou, Marc; Jeutter, Dean C.; Singh, Avtar; Connolly, John P. (Technical Monitor)

    1996-01-01

    Telemetric sensors for monitoring physiological changes in animal models in space are being developed by NASA's Sensors 2000! program. The sensors measure a variety of physiological measurands, including temperature, biopotentials, pressure, flow, acceleration, and chemical levels, and transmit these signals from the animals to a remote receiver via a wireless link. Thus physiologic information can be obtained continuously and automatically without animal handling, tethers, or percutaneous leads. We report here on NASA's development and testing of advanced wireless sensor systems for space life sciences research.

  18. How consumer physical activity monitors could transform human physiology research

    PubMed Central

    Hall Brown, Tyish S.; Collier, Scott R.; Sandberg, Kathryn

    2017-01-01

    A sedentary lifestyle and lack of physical activity are well-established risk factors for chronic disease and adverse health outcomes. Thus, there is enormous interest in measuring physical activity in biomedical research. Many consumer physical activity monitors, including Basis Health Tracker, BodyMedia Fit, DirectLife, Fitbit Flex, Fitbit One, Fitbit Zip, Garmin Vivofit, Jawbone UP, MisFit Shine, Nike FuelBand, Polar Loop, Withings Pulse O2, and others have accuracies similar to that of research-grade physical activity monitors for measuring steps. This review focuses on the unprecedented opportunities that consumer physical activity monitors offer for human physiology and pathophysiology research because of their ability to measure activity continuously under real-life conditions and because they are already widely used by consumers. We examine current and potential uses of consumer physical activity monitors as a measuring or monitoring device, or as an intervention in strategies to change behavior and predict health outcomes. The accuracy, reliability, reproducibility, and validity of consumer physical activity monitors are reviewed, as are limitations and challenges associated with using these devices in research. Other topics covered include how smartphone apps and platforms, such as the Apple ResearchKit, can be used in conjunction with consumer physical activity monitors for research. Lastly, the future of consumer physical activity monitors and related technology is considered: pattern recognition, integration of sleep monitors, and other biosensors in combination with new forms of information processing. PMID:28052867

  19. Evaluation of mobile smartphones app as a screening tool for environmental noise monitoring.

    PubMed

    Ibekwe, Titus S; Folorunsho, David O; Dahilo, Enoch A; Gbujie, Ibeneche O; Nwegbu, Maxwell M; Nwaorgu, Onyekwere G

    2016-01-01

    Noise is a global occupational and environmental health hazard with considerable social and physiological impact and, therefore, there is a need for regular measurements to boost monitoring and regulations of environmental noise levels in our communities. This necessitates a readily available, inexpensive, and easy to use noise measuring device. We aimed to test the sensitivity and validity of mobile "smart" phones for this purpose. This was a comparative analysis of a cross sectional study done between January 2014 and February 2015. Noise levels were measured simultaneously at different locations within Abuja Nigeria at day and night hours in real time environments. A sound level meter (SLM) (Extech407730 Digital Soundmeter, serial no.: 2310135, calibration no: 91037) and three smartphones (Samsung Galaxy note3, Nokia S, and Techno Phantom Z running on Android "Apps" Androidboy1) were used. Statistical calculations were done with Pearson correlation, T-test and Consistency within American National Standards Institute acceptable standard errors. Noise level readings for both daytime and night with the SLM and the mobile phones showed equivalent values. All noise level meters measured were <100dB. The daytime readings were nearly identical in six locations and the maximum difference in values between the SLM and Smartphone instruments was 3db, noted in two locations. Readings in dBA showed strong correlation (r = 0.9) within acceptable error limits for Type 2 SLM devices and no significant difference in the values (p = 0.12 & 0.58) for both day and night. Sensitivity of the instrument yielded 92.9%. The androidboy1 "app" performance in this study showed a good correlation and comparative high sensitivity to the Standard SLM (type 2 SLM device). However there is the need for further studies.

  20. State-of-the-Art Sensor Technology in Spain: Invasive and Non-Invasive Techniques for Monitoring Respiratory Variables

    PubMed Central

    Domingo, Christian; Blanch, Lluis; Murias, Gaston; Luján, Manel

    2010-01-01

    The interest in measuring physiological parameters (especially arterial blood gases) has grown progressively in parallel to the development of new technologies. Physiological parameters were first measured invasively and at discrete time points; however, it was clearly desirable to measure them continuously and non-invasively. The development of intensive care units promoted the use of ventilators via oral intubation ventilators via oral intubation and mechanical respiratory variables were progressively studied. Later, the knowledge gained in the hospital was applied to out-of-hospital management. In the present paper we review the invasive and non-invasive techniques for monitoring respiratory variables. PMID:22399898

  1. State-of-the-art sensor technology in Spain: invasive and non-invasive techniques for monitoring respiratory variables.

    PubMed

    Domingo, Christian; Blanch, Lluis; Murias, Gaston; Luján, Manel

    2010-01-01

    The interest in measuring physiological parameters (especially arterial blood gases) has grown progressively in parallel to the development of new technologies. Physiological parameters were first measured invasively and at discrete time points; however, it was clearly desirable to measure them continuously and non-invasively. The development of intensive care units promoted the use of ventilators via oral intubation ventilators via oral intubation and mechanical respiratory variables were progressively studied. Later, the knowledge gained in the hospital was applied to out-of-hospital management. In the present paper we review the invasive and non-invasive techniques for monitoring respiratory variables.

  2. Smart wireless sensor for physiological monitoring.

    PubMed

    Tomasic, Ivan; Avbelj, Viktor; Trobec, Roman

    2015-01-01

    Presented is a wireless body sensor capable of measuring local potential differences on a body surface. By using on-sensor signal processing capabilities, and developed algorithms for off-line signal processing on a personal computing device, it is possible to record single channel ECG, heart rate, breathing rate, EMG, and when three sensors are applied, even the 12-lead ECG. The sensor is portable, unobtrusive, and suitable for both inpatient and outpatient monitoring. The paper presents the sensor's hardware and results of power consumption analysis. The sensor's capabilities of recording various physiological parameters are also presented and illustrated. The paper concludes with envisioned sensor's future developments and prospects.

  3. Home geriatric physiological measurements.

    PubMed

    Tamura, Toshiyo

    2012-10-01

    In an ageing society, the elderly can be monitored with numerous physiological, physical and passive devices. Sensors can be installed in the home for continuous mobility assistance and unobtrusive disease prevention. This review presents several modern sensors, which improve the quality of life and assist the elderly, disabled people and their caregivers. The main concept of geriatric sensors is that they are capable of providing assistance without limiting or disturbing the subject's daily routine, giving him or her greater comfort, pleasure and well-being. Furthermore, this review includes associated technologies of wearable/implantable monitoring systems and the 'smart-house' project. This review concludes by discussing future challenges of the future aged society.

  4. Evaluating Heavy Metal Stress Levels in Rice Based on Remote Sensing Phenology.

    PubMed

    Liu, Tianjiao; Liu, Xiangnan; Liu, Meiling; Wu, Ling

    2018-03-14

    Heavy metal pollution of croplands is a major environmental problem worldwide. Methods for accurately and quickly monitoring heavy metal stress have important practical significance. Many studies have explored heavy metal stress in rice in relation to physiological function or physiological factors, but few studies have considered phenology, which can be sensitive to heavy metal stress. In this study, we used an integrated Normalized Difference Vegetation Index (NDVI) time-series image set to extract remote sensing phenology. A phenological indicator relatively sensitive to heavy metal stress was chosen from the obtained phenological periods and phenological parameters. The Dry Weight of Roots (WRT), which directly affected by heavy metal stress, was simulated by the World Food Study (WOFOST) model; then, a feature space based on the phenological indicator and WRT was established for monitoring heavy metal stress. The results indicated that the feature space can distinguish the heavy metal stress levels in rice, with accuracy greater than 95% for distinguishing the severe stress level. This finding provides scientific evidence for combining rice phenology and physiological characteristics in time and space, and the method is useful to monitor heavy metal stress in rice.

  5. 41 CFR 102-34.75 - Who is responsible for monitoring our compliance with fuel economy standards for motor vehicles...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... monitoring our compliance with fuel economy standards for motor vehicles we obtain? 102-34.75 Section 102-34... Vehicles § 102-34.75 Who is responsible for monitoring our compliance with fuel economy standards for motor... economy standards for motor vehicles they obtain. ...

  6. 41 CFR 102-34.75 - Who is responsible for monitoring our compliance with fuel economy standards for motor vehicles...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... monitoring our compliance with fuel economy standards for motor vehicles we obtain? 102-34.75 Section 102-34... Vehicles § 102-34.75 Who is responsible for monitoring our compliance with fuel economy standards for motor... economy standards for motor vehicles they obtain. ...

  7. 41 CFR 102-34.75 - Who is responsible for monitoring our compliance with fuel economy standards for motor vehicles...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... monitoring our compliance with fuel economy standards for motor vehicles we obtain? 102-34.75 Section 102-34... Vehicles § 102-34.75 Who is responsible for monitoring our compliance with fuel economy standards for motor... economy standards for motor vehicles they obtain. ...

  8. 41 CFR 102-34.75 - Who is responsible for monitoring our compliance with fuel economy standards for motor vehicles...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... monitoring our compliance with fuel economy standards for motor vehicles we obtain? 102-34.75 Section 102-34... Vehicles § 102-34.75 Who is responsible for monitoring our compliance with fuel economy standards for motor... economy standards for motor vehicles they obtain. ...

  9. a Weather Monitoring System for Application to Apple and Corn Production

    NASA Astrophysics Data System (ADS)

    Stirm, Walter Leroy

    Many crop management decisions are based on weather -crop development relationships. Daily weather data is currently used in most crop development research and applied models. Present weather and computer technology now makes possible monitoring of crop development on a realtime basis. This research tests a method of computing crop sensitive temperatures for corn and apple using standard hourly meteorological data. The method also makes use of detailed plant physiological stage measurements to determine timing of vital cultural operations tied to the observed weather conditions. The sensitive temperature method incorporates very short term weather variability accounting for changes in the cloud cover, radiation rates, evaporative cooling and other factors involved in the plant's energy balance. The relationship of plant and weather measurements are also used to determine corn emergence, corn grain drydown rate and fruit harvest duration. The monitoring system also incorporates a crop growth unit forecast technique employing short and medium range temperature forecasts of the National Weather Service. The projections of growth units are made for five and ten days into the future. Predicted growth unit accumulations are compared to historical growth unit accumulations to determine the forecast stage. The sensitive temperature crop monitoring system removes some of the error involved in evaluation of growth units by average daily temperature. Carry over maximum and minimums, extended duration of warm or cool periods within the day and disruption of diurnal temperature curve by passage of fronts are eliminated.

  10. Applications of tapered flat silver halide fiber elements for infrared biospectroscopy with aspects of optical stability and biocompatibility

    NASA Astrophysics Data System (ADS)

    Delbeck, Sven; Küpper, Lukas; Heise, Herbert M.

    2018-02-01

    Spectroscopic analysis of different biofluids and bodyfluid-like media has been realized by using tapered flat silver halide fiber elements as infrared biosensors. Optical stability and biocompatibility testing of the sensor elements have been performed with in-vitro samples under representative physiological conditions. After improving the reproducibility of manufacturing the sensor elements, the incoupling of radiation and the general handling including their chemical composition characterization, the fiber sensors were further optimized for the experiments. Stability tests in physiological solutions as well as porcine blood have shown that best results for biospectroscopic applications are available for the mid-IR fingerprint region, with the most stable behaviour as analyzed by the single-beam spectra. Despite several contrary reports, the silver halide material tested is toxic to cell lines chosen from the DIN standard specification for biocompatibility testing. Spectral changes as well as the results based on the DIN standard showed that pretreatment of the fibers is unavoidable to prevent direct contact of cells or human tissue and the silver halide material. Further applications of tapered flat silver halide fibers for the quantification of analytes in bodyfluids have also been tested by ensheathing the fiber-optic sensor element with a dialysis membrane. With the successfully produced prototype, results of diffusion rates and performance of a membrane-ensheathed fiber probe have been obtained. An invitro monitoring fiber sensor was developed aiming at the implantation of a microdialysis system for the analytical quantification of biomolecules such as glucose, lactate and others.

  11. Instructional Methods for Neuroscience in Nurse Anesthesia Graduate Programs: A Survey of Educational Programs

    DTIC Science & Technology

    1999-10-01

    Sciences A. Anatomy, physiology and pathophysiology 1. Cardiovascular a. Arrhythmias b. Ischemic heart disease/angina c. Myocardial infarction d...Hypertension e. Congestive Heart Failure f. Shock Instructional Methods 66 g. Valvular Heart disease h. Cardiomyopathy i. Peripheral vascular disease j...Pulmonary artery pressure monitoring Instructional Methods 71 3. Precordial/esophageal stethoscope /Doppler 4. Respiratory monitoring a. Apnea monitor b

  12. Dan Johnson's impact on hearing research

    NASA Astrophysics Data System (ADS)

    Shotland, Lawrence I.

    2003-04-01

    Daniel L. Johnson is well known for his many technical contributions to noise research. Throughout a long and distinguished career at Wright-Patterson Air Force Base, Dan published the results of several significant experiments, including his landmark experiments on asymptotic threshold shift and exposure to impulse noise. His work in the area of noise exposure laid much of the groundwork for a greater understanding of the physiologic response to hazardous noise, much of which has since been incorporated in national and international standards. Dan is highly regarded for his tireless work on technical and advisory committees in noise, and most recently, ototoxicity. Throughout his career, Dan has adhered to a self-imposed standard of intellectual honesty and discovery. Dan's most recent endeavor, the development of a personal noise dosimeter designed for self-monitoring by the employee, is characteristic of his creativity and energy. Perhaps less well known are his contributions over the years to the success of his younger colleagues. He has accomplished this in an unselfish and egalitarian manner, oftentimes challenging and even contradicting his own research. The focus of this talk will elaborate on these facets of Dan's professional contributions.

  13. New Mexico state traffic monitoring standards, calendar year 2009-2010

    DOT National Transportation Integrated Search

    2010-01-01

    What follows are New Mexico's State Traffic Monitoring Standards : (NMSTMS) to be used for all New Mexico Traffic Monitoring activities. : The standards were first implemented on October 1, 1988. They : continue to be reviewed and refined on a three-...

  14. Developing policy, standard orders, and quality-assurance monitoring for palliative sedation therapy.

    PubMed

    Ghafoor, Virginia L; Silus, Lauren S

    2011-03-15

    The development of a policy, evidence-based standard orders, and monitoring for palliative sedation therapy (PST) is described. Concerns regarding PST at the University of Minnesota Medical Center (UMMC) arose and needed to be addressed in a formal process. A multidisciplinary group consisting of palliative care physicians, nurse practitioners, clinical nurse specialists, and clinical pharmacy specialists reached consensus on the practice model and medications to be used for PST. Major elements of the plan included the development and implementation of an institutional policy for palliative sedation; standard orders for patient care, sedation, and monitoring; education for staff, patients, and patients' family members; and quality-assurance monitoring. A literature review was performed to identify research and guidelines defining the practice of PST. Policy content includes the use of a standard order set linking patient care, medication administration, the monitoring of sedation, and symptom management. Approval of the policy involved several UMMC committees. An evaluation matrix was used to determine critical areas for PST monitoring and to guide development of a form to monitor quality. A retrospective chart audit using the quality-assurance monitoring form assessed baseline sedation medication and patient outcomes. Assessment of compliance began in the fall of 2008, after the policy and standard orders were approved by the UMMC medical executive committee. In 2008, two cases of PST were monitored using the standardized form. PST cases will be continually monitored and analyzed. Development of policy, standard orders, and quality-assurance monitoring for PST required a formal multidisciplinary process. A process-improvement process is critical to defining institutional policy, educational goals, and outcome metrics for PST.

  15. An overview of current approaches and future challenges in physiological monitoring

    NASA Technical Reports Server (NTRS)

    Horst, Richard L.

    1988-01-01

    Sufficient evidence exists from laboratory studies to suggest that physiological measures can be useful as an adjunct to behavioral and subjective measures of human performance and capabilities. Thus it is reasonable to address the conceptual and engineering challenges that arise in applying this technology in operational settings. Issues reviewed include the advantages and disadvantages of constructs such as mental states, the need for physiological measures of performance, areas of application for physiological measures in operational settings, which measures appear to be most useful, problem areas that arise in the use of these measures in operational settings, and directions for future development.

  16. Real-time human collaboration monitoring and intervention

    DOEpatents

    Merkle, Peter B.; Johnson, Curtis M.; Jones, Wendell B.; Yonas, Gerold; Doser, Adele B.; Warner, David J.

    2010-07-13

    A method of and apparatus for monitoring and intervening in, in real time, a collaboration between a plurality of subjects comprising measuring indicia of physiological and cognitive states of each of the plurality of subjects, communicating the indicia to a monitoring computer system, with the monitoring computer system, comparing the indicia with one or more models of previous collaborative performance of one or more of the plurality of subjects, and with the monitoring computer system, employing the results of the comparison to communicate commands or suggestions to one or more of the plurality of subjects.

  17. [Prescribing monitoring in clinical practice: from enlightened empiricism to rational strategies].

    PubMed

    Buclin, Thierry; Herzig, Lilli

    2013-05-15

    Monitoring of a medical condition is the periodic measurement of one or several physiological or biological variables to detect a signal regarding its clinical progression or its response to treatment. We distinguish different medical situations between diagnostic, clinical and therapeutic process to apply monitoring. Many clinical, variables can be used for monitoring, once their intrinsic properties (normal range, critical difference, kinetics, reactivity) and external validity (pathophysiological importance, predictive power for clinical outcomes) are established. A formal conceptualization of monitoring is being developed and should support the rational development of monitoring strategies and their validation through appropriate clinical trials.

  18. Cerebral monitoring devices: what we pay for.

    PubMed

    Bonhomme, V; Hans, P

    2006-01-01

    In this review paper, the authors analyse advantages, pitfalls and economical considerations related to depth of anaesthesia monitoring. They first describe the most widely distributed monitors in Europe, and the physiological basis of each index. The optimal use of those monitors and their demonstrated clinical benefits are detailed, as well as the circumstances that can lead to erroneous information or interpretation. Knowledge of patients and practitioners, as well as beliefs and expectations regarding depth of anaesthesia monitoring are discussed. Finally, the authors give their own opinion regarding the use of depth of anaesthesia monitoring, according to clinical benefit and economical considerations.

  19. Anxiety and Error Monitoring: Increased Error Sensitivity or Altered Expectations?

    ERIC Educational Resources Information Center

    Compton, Rebecca J.; Carp, Joshua; Chaddock, Laura; Fineman, Stephanie L.; Quandt, Lorna C.; Ratliff, Jeffrey B.

    2007-01-01

    This study tested the prediction that the error-related negativity (ERN), a physiological measure of error monitoring, would be enhanced in anxious individuals, particularly in conditions with threatening cues. Participants made gender judgments about faces whose expressions were either happy, angry, or neutral. Replicating prior studies, midline…

  20. Physiological measures and mental-state assessment

    NASA Technical Reports Server (NTRS)

    Stern, John A.

    1988-01-01

    General considerations regarding monitoring of operators for alertness are discussed, including who should be monitored and what information should be collected. Measures that have been used to ascertain more general and persistent states of alertness are outlined, including cardiac activity, peripheral vascular activity, skin conductance, electroencephalography, pupillography, oculomotor activity, and body movements.

  1. Development of concept-based physiology lessons for biomedical engineering undergraduate students.

    PubMed

    Nelson, Regina K; Chesler, Naomi C; Strang, Kevin T

    2013-06-01

    Physiology is a core requirement in the undergraduate biomedical engineering curriculum. In one or two introductory physiology courses, engineering students must learn physiology sufficiently to support learning in their subsequent engineering courses and careers. As preparation for future learning, physiology instruction centered on concepts may help engineering students to further develop their physiology and biomedical engineering knowledge. Following the Backward Design instructional model, a series of seven concept-based lessons was developed for undergraduate engineering students. These online lessons were created as prerequisite physiology training to prepare students to engage in a collaborative engineering challenge activity. This work is presented as an example of how to convert standard, organ system-based physiology content into concept-based content lessons.

  2. Wireless pilot monitoring system for extreme race conditions.

    PubMed

    Pino, Esteban J; Arias, Diego E; Aqueveque, Pablo; Melin, Pedro; Curtis, Dorothy W

    2012-01-01

    This paper presents the design and implementation of an assistive device to monitor car drivers under extreme conditions. In particular, this system is designed in preparation for the 2012 Atacama Solar Challenge to be held in the Chilean desert. Actual preliminary results show the feasibility of such a project including physiological and ambient sensors, real-time processing algorithms, wireless data transmission and a remote monitoring station. Implementation details and field results are shown along with a discussion of the main problems found in real-life telemetry monitoring.

  3. Impaired cerebral autoregulation and brain injury in newborns with hypoxic-ischemic encephalopathy treated with hypothermia.

    PubMed

    Massaro, An N; Govindan, R B; Vezina, Gilbert; Chang, Taeun; Andescavage, Nickie N; Wang, Yunfei; Al-Shargabi, Tareq; Metzler, Marina; Harris, Kari; du Plessis, Adre J

    2015-08-01

    Impaired cerebral autoregulation may contribute to secondary injury in newborns with hypoxic-ischemic encephalopathy (HIE). Continuous, noninvasive assessment of cerebral pressure autoregulation can be achieved with bedside near-infrared spectroscopy (NIRS) and systemic mean arterial blood pressure (MAP) monitoring. This study aimed to evaluate whether impaired cerebral autoregulation measured by NIRS-MAP monitoring during therapeutic hypothermia and rewarming relates to outcome in 36 newborns with HIE. Spectral coherence analysis between NIRS and MAP was used to quantify changes in the duration [pressure passivity index (PPI)] and magnitude (gain) of cerebral autoregulatory impairment. Higher PPI in both cerebral hemispheres and gain in the right hemisphere were associated with neonatal adverse outcomes [death or detectable brain injury by magnetic resonance imaging (MRI), P < 0.001]. NIRS-MAP monitoring of cerebral autoregulation can provide an ongoing physiological biomarker that may help direct care in perinatal brain injury. Copyright © 2015 the American Physiological Society.

  4. Smart garments for safety improvement of emergency/disaster operators.

    PubMed

    Curone, Davide; Dudnik, Gabriela; Loriga, Giannicola; Luprano, Jean; Magenes, Giovanni; Paradiso, Rita; Tognetti, Alessandro; Bonfiglio, Annalisa

    2007-01-01

    The main purpose of the European project ProeTEX is to develop equipment to improve safety, coordination and efficiency of emergency disaster intervention personnel like fire-fighters or civil protection rescuers. The equipment consists of a new generation of "smart" garments, integrating wearable sensors which will allow monitoring physiological parameters, position and activity of the user, as like as environmental variables of the operating field in which rescuers are working: both commercial and newly developed textile and fibre based sensors will be included. The garments will also contain an electronic box to process data collected by the sensors and a communication system enabling the transmission of data to the other rescuers and to a monitoring station. Also a "smart" victim patch will be developed: a wearable garment which will allow monitoring physiological parameters of injured civilians involved in disasters, with the aim of optimizing their survival management.

  5. Clinical assessment of the male fertility

    PubMed Central

    Khatun, Amena; Rahman, Md Saidur

    2018-01-01

    The evaluation of infertility in males consists of physical examination and semen analyses. Standardized semen analyses depend on the descriptive analysis of sperm motility, morphology, and concentration, with a threshold level that must be surpassed to be considered a fertile spermatozoon. Nonetheless, these conventional parameters are not satisfactory for clinicians since 25% of infertility cases worldwide remain unexplained. Therefore, newer tests methods have been established to investigate sperm physiology and functions by monitoring characteristics such as motility, capacitation, the acrosome reaction, reactive oxygen species, sperm DNA damage, chromatin structure, zona pellucida binding, and sperm-oocyte fusion. After the introduction of intracytoplasmic sperm injection technique, sperm maturity, morphology, and aneuploidy conditions have gotten more attention for investigating unexplained male infertility. In the present article, recent advancements in research regarding the utilization of male fertility prediction tests and their role and accuracy are reviewed. PMID:29564308

  6. Measuring Cardiac Autonomic Nervous System (ANS) Activity in Toddlers - Resting and Developmental Challenges.

    PubMed

    Bush, Nicole R; Caron, Zoe K; Blackburn, Katherine S; Alkon, Abbey

    2016-02-25

    The autonomic nervous system (ANS) consists of two branches, the parasympathetic and sympathetic nervous systems, and controls the function of internal organs (e.g., heart rate, respiration, digestion) and responds to everyday and adverse experiences (1). ANS measures in children have been found to be related to behavior problems, emotion regulation, and health (2-7). Therefore, understanding the factors that affect ANS development during early childhood is important. Both branches of the ANS affect young children's cardiovascular responses to stimuli and have been measured noninvasively, via external monitoring equipment, using valid and reliable measures of physiological change (8-11). However, there are few studies of very young children with simultaneous measures of the parasympathetic and sympathetic nervous systems, which limits understanding of the integrated functioning of the two systems. In addition, the majority of existing studies of young children report on infants' resting ANS measures or their reactivity to commonly used mother-child interaction paradigms, and less is known about ANS reactivity to other challenging conditions. We present a study design and standardized protocol for a non-invasive and rapid assessment of cardiac autonomic control in 18 month old children. We describe methods for continuous monitoring of the parasympathetic and sympathetic branches of the ANS under resting and challenge conditions during a home or laboratory visit and provide descriptive findings from our sample of 140 ethnically diverse toddlers using validated equipment and scoring software. Results revealed that this protocol can produce a range of physiological responses to both resting and developmentally challenging conditions, as indicated by changes in heart rate and indices of parasympathetic and sympathetic activity. Individuals demonstrated variability in resting levels, responses to challenges, and challenge reactivity, which provides additional evidence that this protocol is useful for the examination of ANS individual differences for toddlers.

  7. Micro- and nanoengineering for stem cell biology: the promise with a caution.

    PubMed

    Kshitiz; Kim, Deok-Ho; Beebe, David J; Levchenko, Andre

    2011-08-01

    Current techniques used in stem cell research only crudely mimic the physiological complexity of the stem cell niches. Recent advances in the field of micro- and nanoengineering have brought an array of in vitro cell culture models that have enabled development of novel, highly precise and standardized tools that capture physiological details in a single platform, with greater control, consistency, and throughput. In this review, we describe the micro- and nanotechnology-driven modern toolkit for stem cell biologists to design novel experiments in more physiological microenvironments with increased precision and standardization, and caution them against potential challenges that the modern technologies might present. Copyright © 2011 Elsevier Ltd. All rights reserved.

  8. Assessment of Fluid Balance and the Approach to Fluid Therapy in the Perioperative Patient.

    PubMed

    Boller, Elise; Boller, Manuel

    2015-09-01

    Perioperative patients can be highly dynamic and have various metabolic, physiologic, and organ system derangements that necessitate smart monitoring strategies and careful fluid therapy. The interplay between changing patient status, therapeutic interventions, and patient response makes effective monitoring crucial to successful treatment. Monitoring the perioperative patient and an approach to fluid therapy are discussed in this text. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Revolutionary optical sensor for physiological monitoring in the battlefield

    NASA Astrophysics Data System (ADS)

    Kingsley, Stuart A.; Sriram, Sriram; Pollick, Andrea; Marsh, John

    2004-09-01

    SRICO has developed a revolutionary approach to physiological status monitoring using state-of-the-art optical chip technology. The company"s patent pending Photrode is a photonic electrode that uses unique optical voltage sensing technology to measure and monitor electrophysiological parameters. The optical-based monitoring system enables dry-contact measurements of EEG and ECG signals that require no surface preparation or conductive gel and non-contact measurements of ECG signals through the clothing. The Photrode applies high performance optical integrated circuit technology, that has been successfully implemented in military & commercial aerospace, missile, and communications applications for sensing and signal transmission. SRICO"s award winning Photrode represents a new paradigm for the measurement of biopotentials in a reliable, convenient, and non-intrusive manner. Photrode technology has significant applications on the battlefield for rapid triage to determine the brain dead from those with viable brain function. An ECG may be obtained over the clothing without any direct skin contact. Such applications would enable the combat medic to receive timely medical information and to make important decisions regarding identification, location, triage priority and treatment of casualties. Other applications for the Photrode include anesthesia awareness monitoring, sleep medicine, mobile medical monitoring for space flight, emergency patient care, functional magnetic resonance imaging, various biopotential signal acquisition (EMG, EOG), and routine neuro and cardio diagnostics.

  10. 40 CFR 75.32 - Determination of monitor data availability for standard missing data procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... availability for standard missing data procedures. 75.32 Section 75.32 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTINUOUS EMISSION MONITORING Missing Data Substitution Procedures § 75.32 Determination of monitor data availability for standard missing data procedures...

  11. 40 CFR 75.32 - Determination of monitor data availability for standard missing data procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... availability for standard missing data procedures. 75.32 Section 75.32 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTINUOUS EMISSION MONITORING Missing Data Substitution Procedures § 75.32 Determination of monitor data availability for standard missing data procedures...

  12. 40 CFR 75.32 - Determination of monitor data availability for standard missing data procedures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... availability for standard missing data procedures. 75.32 Section 75.32 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTINUOUS EMISSION MONITORING Missing Data Substitution Procedures § 75.32 Determination of monitor data availability for standard missing data procedures...

  13. 40 CFR 75.32 - Determination of monitor data availability for standard missing data procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... availability for standard missing data procedures. 75.32 Section 75.32 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTINUOUS EMISSION MONITORING Missing Data Substitution Procedures § 75.32 Determination of monitor data availability for standard missing data procedures...

  14. 40 CFR 75.32 - Determination of monitor data availability for standard missing data procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... availability for standard missing data procedures. 75.32 Section 75.32 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTINUOUS EMISSION MONITORING Missing Data Substitution Procedures § 75.32 Determination of monitor data availability for standard missing data procedures...

  15. System theory in industrial patient monitoring: an overview.

    PubMed

    Baura, G D

    2004-01-01

    Patient monitoring refers to the continuous observation of repeating events of physiologic function to guide therapy or to monitor the effectiveness of interventions, and is used primarily in the intensive care unit and operating room. Commonly processed signals are the electrocardiogram, intraarterial blood pressure, arterial saturation of oxygen, and cardiac output. To this day, the majority of physiologic waveform processing in patient monitors is conducted using heuristic curve fitting. However in the early 1990s, a few enterprising engineers and physicians began using system theory to improve their core processing. Applications included improvement of signal-to-noise ratio, either due to low signal levels or motion artifact, and improvement in feature detection. The goal of this mini-symposium is to review the early work in this emerging field, which has led to technologic breakthroughs. In this overview talk, the process of system theory algorithm research and development is discussed. Research for industrial monitors involves substantial data collection, with some data used for algorithm training and the remainder used for validation. Once the algorithms are validated, they are translated into detailed specifications. Development then translates these specifications into DSP code. The DSP code is verified and validated per the Good Manufacturing Practices mandated by FDA.

  16. Putting intelligent structured intermittent auscultation (ISIA) into practice.

    PubMed

    Maude, Robyn M; Skinner, Joan P; Foureur, Maralyn J

    2016-06-01

    Fetal monitoring guidelines recommend intermittent auscultation for the monitoring of fetal wellbeing during labour for low-risk women. However, these guidelines are not being translated into practice and low-risk women birthing in institutional maternity units are increasingly exposed to continuous cardiotocographic monitoring, both on admission to hospital and during labour. When continuous fetal monitoring becomes routinised, midwives and obstetricians lose practical skills around intermittent auscultation. To support clinical practice and decision-making around auscultation modality, the intelligent structured intermittent auscultation (ISIA) framework was developed. The purpose of this discussion paper is to describe the application of intelligent structured intermittent auscultation in practice. The intelligent structured intermittent auscultation decision-making framework is a knowledge translation tool that supports the implementation of evidence into practice around the use of intermittent auscultation for fetal heart monitoring for low-risk women during labour. An understanding of the physiology of the materno-utero-placental unit and control of the fetal heart underpin the development of the framework. Intelligent structured intermittent auscultation provides midwives with a robust means of demonstrating their critical thinking and clinical reasoning and supports their understanding of normal physiological birth. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  17. Monitoring peripheral perfusion and microcirculation.

    PubMed

    Dubin, Arnaldo; Henriquez, Elizabeth; Hernández, Glenn

    2018-06-01

    Microcirculatory alterations play a major role in the pathogenesis of shock. Monitoring tissue perfusion might be a relevant goal for shock resuscitation. The goal of this review was to revise the evidence supporting the monitoring of peripheral perfusion and microcirculation as goals of resuscitation. For this purpose, we mainly focused on skin perfusion and sublingual microcirculation. Although there are controversies about the reproducibility of capillary refill time in monitoring peripheral perfusion, it is a sound physiological variable and suitable for the ICU settings. In addition, observational studies showed its strong ability to predict outcome. Moreover, a preliminary study suggested that it might be a valuable goal for resuscitation. These results should be confirmed by the ongoing ANDROMEDA-SHOCK randomized controlled trial. On the other hand, the monitoring of sublingual microcirculation might also provide relevant physiological and prognostic information. On the contrary, methodological drawbacks mainly related to video assessment hamper its clinical implementation at the present time. Measurements of peripheral perfusion might be useful as goal of resuscitation. The results of the ANDROMEDA-SHOCK will clarify the role of skin perfusion as a guide for the treatment of shock. In contrast, the assessment of sublingual microcirculation mainly remains as a research tool.

  18. Wearable Wireless Sensor for Multi-Scale Physiological Monitoring

    DTIC Science & Technology

    2013-10-01

    AD_________________ Award Number: W81XWH-12-1-0541 TITLE: Wearable Wireless Sensor for Multi-Scale...TYPE Annual 3. DATES COVERED 25 12- 13 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER Wearable Wireless Sensor for Multi-Scale Physiological...peripheral management • Procedures for low power mode activation and wake - up • Routines for start- up state detection • Flash memory management

  19. Awake craniotomy in a patient with ejection fraction of 10%: considerations of cerebrovascular and cardiovascular physiology.

    PubMed

    Meng, Lingzhong; Weston, Stephen D; Chang, Edward F; Gelb, Adrian W

    2015-05-01

    A 37-year-old man with nonischemic 4-chamber dilated cardiomyopathy and low-output cardiac failure (estimated ejection fraction of 10%) underwent awake craniotomy for a low-grade oligodendroglioma resection under monitored anesthesia care. The cerebrovascular and cardiovascular physiologic challenges and our management of this patient are discussed. Published by Elsevier Inc.

  20. Standing on the Shoulders of Giants: Dean Franklin and His Remarkable Contributions to Physiological Measurements in Animals

    ERIC Educational Resources Information Center

    Sarazan, R. Dustan; Schweitz, Karl T. R.

    2009-01-01

    The use of electronic instrumentation to monitor physiological function in conscious research animals and humans has become routine. Beyond basic research, animal studies using these methods are required by government regulatory agencies worldwide before human testing of potential new drugs. Living, as we do, in an age of miniaturized high-tech…

  1. Symptom prevalence and physiologic biomarkers among adolescents using a mobile phone intervention following hematopoietic stem cell transplantation.

    PubMed

    Rodgers, Cheryl C; Krance, Robert; Street, Richard L; Hockenberry, Marilyn J

    2014-05-01

    To examine symptom reports and physiologic parameters in adolescents using the Eating After Transplant (EAT!) intervention during recovery after hematopoietic stem cell transplantation (HSCT). Repeated measures design. HSCT service at a pediatric teaching institution in the southern United States. 16 adolescents recovering from a first-time allogeneic HSCT. Use of EAT! was monitored electronically, symptom reports were obtained from a questionnaire, and physiologic parameters were obtained from the medical record at HSCT hospital discharge and 20, 40, and 60 days postdischarge. EAT! use, symptom prevalence, symptom-related distress, and physiologic parameters including weight, body mass index (BMI), pre-albumin, and albumin. Symptom prevalence was highest at hospital discharge and steadily declined; however, mean symptom distress scores remained stable. Mean weight and BMI significantly declined during the first 60 days postdischarge; pre-albumin and albumin markers were unchanged. No correlation was noted among use of EAT! and any research variables. The most frequent symptoms were not always the most distressing symptoms. Weight and BMI significantly declined during HSCT recovery. Nurses should assess symptom frequency and distress to fully understand patients' symptom experiences. Nurses should monitor weight and BMI throughout HSCT recovery.

  2. Monitoring of endogenous carbon monoxide dynamics in human breath by tunable diode laser

    NASA Astrophysics Data System (ADS)

    Stepanov, Eugene V.; Daraselia, Mikhail V.; Zyrianov, Pavel V.; Shulagin, Yurii A.; Skrupskii, Vladimir A.

    1996-01-01

    High sensitive CO gas analyzer based on tunable diode laser (TDL) was used as a real time monitor of endogenous carbon monoxide in a set of breath physiology experiments. The measurements of the CO content dynamics in exhaled air with 10 ppb sensitivity were attended with detection of carbon dioxide and O2 in breath, lung ventilation parameters, heart rate and blood analysis using conventional techniques. Temporal variations of endogenous CO in human breath caused by hyperoxia, hypoxia, hyperventilation and sport loading were first studied in real time. Scattering of the CO variation time constants was observed for different tested persons. Possible reasons for this scattering related with the organisms' physiology peculiarities are discussed.

  3. Endogenous CO dynamics monitoring in breath by tunable diode laser

    NASA Astrophysics Data System (ADS)

    Kouznetsov, Andrian I.; Stepanov, Eugene V.; Shulagin, Yurii A.; Skrupskii, Vladimir A.

    1996-04-01

    High sensitive CO gas analyzer based on tunable diode laser (TDL) was used as a real time monitor of endogenous carbon monoxide in a set of breath physiology experiments. The measurements of the CO content dynamics in exhaled air with 10 ppb sensitivity were attended with detection of carbon dioxide and O2 in breath, lung ventilation parameters, heart rate and blood analysis using conventional techniques. Variations of endogenous CO in human breath caused by hyperoxia, hypoxia, hyperventilation as well as sport loading were studied in real time. Scattering of the CO variation time constants was observed for different tested persons. Possible reasons for this scattering related with the organisms' physiology peculiarities are discussed.

  4. Ambulatory instrumentation suitable for long-term monitoring of cattle health.

    PubMed

    Schoenig, S A; Hildreth, T S; Nagl, L; Erickson, H; Spire, M; Andresen, D; Warren, S

    2004-01-01

    The benefits of real-time health diagnoses of cattle are potentially tremendous. Early detection of transmissible disease, whether from natural or terrorist events, could help to avoid huge financial losses in the agriculture industry while also improving meat quality. This work discusses physiological and behavioral parameters relevant to cattle state-of-health assessment. These parameters, along with a potentially harsh monitoring environment, drive a set of design considerations that must be addressed when building systems to acquire long-term, real-time measurements in the field. A prototype system is presented that supports the measurement of suitable physiologic parameters and begins to address the design constraints for continuous state-of-health determination in free-roaming cattle.

  5. Synchrosqueezing an effective method for analyzing Doppler radar physiological signals.

    PubMed

    Yavari, Ehsan; Rahman, Ashikur; Jia Xu; Mandic, Danilo P; Boric-Lubecke, Olga

    2016-08-01

    Doppler radar can monitor vital sign wirelessly. Respiratory and heart rate have time-varying behavior. Capturing the rate variability provides crucial physiological information. However, the common time-frequency methods fail to detect key information. We investigate Synchrosqueezing method to extract oscillatory components of the signal with time varying spectrum. Simulation and experimental result shows the potential of the proposed method for analyzing signals with complex time-frequency behavior like physiological signals. Respiration and heart signals and their components are extracted with higher resolution and without any pre-filtering and signal conditioning.

  6. Musculoskeletal overuse injuries and heart rate variability: Is there a link?

    PubMed

    Gisselman, Angela Spontelli; Baxter, G David; Wright, Alexis; Hegedus, Eric; Tumilty, Steve

    2016-02-01

    Accurate detection and prevention of overuse musculoskeletal injuries is limited by the nature of somatic tissue injury. In the pathogenesis of overuse injuries, it is well recognized that an abnormal inflammatory response occurs within somatic tissue before pain is perceived which can disrupt the normal remodeling process and lead to subsequent degeneration. Current overuse injury prevention methods focused on biomechanical faults or performance standards lack the sensitivity needed to identify the status of tissue injury or repair. Recent evidence has revealed an apparent increase in the prevalence and impact of overuse musculoskeletal injuries in athletics. When compared to acute injuries, overuse injuries have a potentially greater negative impact on athletes' overall health burden. Further, return to sport rehabilitation following overuse injury is complicated by the fact that the absence of pain does not equate to complete physiological healing of the injured tissue. Together, this highlights the need for exercise monitoring and injury prevention methods which incorporate assessment of somatic tissue response to loading. One system primarily involved in the activation of pathways and neuromediators responsible for somatic tissue repair is the autonomic nervous system (ANS). Although not completely understood, emerging research supports the critical importance of peripheral ANS activity in the health and repair of somatic tissue injury. Due to its significant contributions to cardiac function, ANS activity can be measured indirectly with heart rate monitoring. Heart rate variability (HRV) is one index of ANS activity that has been used to investigate the relationship between athletes' physiological response to accumulating training load. Research findings indicated that HRV may provide a reflection of ANS homeostasis, or the body's stress-recovery status. This noninvasive marker of the body's primary driver of recovery has the potential to incorporate important and as yet unmonitored physiological mechanisms involved in overuse injury development. We hypothesize that abnormal somatic tissue response to accumulating microtrauma may modulate ANS activity at the level of HRV. Exploring the link between HRV modulation and somatic tissue injury has the potential to reveal the putative role of ANS homeostasis on overuse musculoskeletal injury development. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Estimation of physiological sub-millimeter displacement with CW Doppler radar.

    PubMed

    Jia Xu; Xiaomeng Gao; Padasdao, Bryson E; Boric-Lubecke, Olga

    2015-01-01

    Doppler radar physiological sensing has been studied for non-contact detection of vital signs including respiratory and heartbeat rates. This paper presents the first micrometer resolution Wi-Fi band Doppler radar for sub-millimeter physiological displacement measurement. A continuous-wave Doppler radar working at 2.4GHz is used for the measurement. It is intended for estimating small displacements on the body surface resulting from physiological activity. A mechanical mover was used as target, and programmed to conduct sinusoidal motions to simulate pulse motions. Measured displacements were compared with a reference system, which indicates a superior performance in accuracy for having absolute errors less than 10μm, and relative errors below 4%. It indicates the feasibility of highly accurate non-contact monitoring of physiological movements using Doppler radar.

  8. Novel image cytometric method for detection of physiological and metabolic changes in Saccharomyces cerevisiae.

    PubMed

    Chan, Leo L; Kury, Alexandria; Wilkinson, Alisha; Berkes, Charlotte; Pirani, Alnoor

    2012-11-01

    The studying and monitoring of physiological and metabolic changes in Saccharomyces cerevisiae (S. cerevisiae) has been a key research area for the brewing, baking, and biofuels industries, which rely on these economically important yeasts to produce their products. Specifically for breweries, physiological and metabolic parameters such as viability, vitality, glycogen, neutral lipid, and trehalose content can be measured to better understand the status of S. cerevisiae during fermentation. Traditionally, these physiological and metabolic changes can be qualitatively observed using fluorescence microscopy or flow cytometry for quantitative fluorescence analysis of fluorescently labeled cellular components associated with each parameter. However, both methods pose known challenges to the end-users. Specifically, conventional fluorescent microscopes lack automation and fluorescence analysis capabilities to quantitatively analyze large numbers of cells. Although flow cytometry is suitable for quantitative analysis of tens of thousands of fluorescently labeled cells, the instruments require a considerable amount of maintenance, highly trained technicians, and the system is relatively expensive to both purchase and maintain. In this work, we demonstrate the first use of Cellometer Vision for the kinetic detection and analysis of vitality, glycogen, neutral lipid, and trehalose content of S. cerevisiae. This method provides an important research tool for large and small breweries to study and monitor these physiological behaviors during production, which can improve fermentation conditions to produce consistent and higher-quality products.

  9. Stellate ganglion blockade and verbal memory in midlife women: Evidence from a randomized trial.

    PubMed

    Maki, Pauline M; Rubin, Leah H; Savarese, Antonia; Drogos, Lauren; Shulman, Lee P; Banuvar, Suzanne; Walega, David R

    2016-10-01

    In a pilot randomized clinical trial of active stellate ganglion blockade (SGB) versus sham control, SGB significantly reduced the frequency of reported moderate to severe vasomotor symptoms (VMS) and the frequency of physiologic VMS measured using ambulatory skin conductance monitors. Here we examine secondary effects of SGB on verbal learning and memory. In a randomized, sham-controlled study, 36 women met eligibility criteria for cognitive assessments, of whom 17 were randomized to receive fluoroscopy-guided SGB and 19 to sham control. At baseline and three months post-treatment, women completed tests of verbal learning and memory (primary outcome) and other cognitive measures and also wore an ambulatory monitor for 24h to measure physiologic VMS and VMS reported in real time. Verbal learning improved following active SGB (p<0.05) but not sham treatment; however, the interaction between group and time was not significant (p values 0.13-0.20). Two secondary cognitive measures improved only in the sham group. Improvements in physiologic VMS correlated significantly with improvements in verbal learning (r=0.51, p<0.05). SGB might confer benefits to memory in relation to the magnitude of improvement in physiologic VMS. Broadly these findings suggest a possible link between physiologic VMS and memory problems in midlife women. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  10. Scalable Manufacturing of Solderable and Stretchable Physiologic Sensing Systems.

    PubMed

    Kim, Yun-Soung; Lu, Jesse; Shih, Benjamin; Gharibans, Armen; Zou, Zhanan; Matsuno, Kristen; Aguilera, Roman; Han, Yoonjae; Meek, Ann; Xiao, Jianliang; Tolley, Michael T; Coleman, Todd P

    2017-10-01

    Methods for microfabrication of solderable and stretchable sensing systems (S4s) and a scaled production of adhesive-integrated active S4s for health monitoring are presented. S4s' excellent solderability is achieved by the sputter-deposited nickel-vanadium and gold pad metal layers and copper interconnection. The donor substrate, which is modified with "PI islands" to become selectively adhesive for the S4s, allows the heterogeneous devices to be integrated with large-area adhesives for packaging. The feasibility for S4-based health monitoring is demonstrated by developing an S4 integrated with a strain gauge and an onboard optical indication circuit. Owing to S4s' compatibility with the standard printed circuit board assembly processes, a variety of commercially available surface mount chip components, such as the wafer level chip scale packages, chip resistors, and light-emitting diodes, can be reflow-soldered onto S4s without modifications, demonstrating the versatile and modular nature of S4s. Tegaderm-integrated S4 respiration sensors are tested for robustness for cyclic deformation, maximum stretchability, durability, and biocompatibility for multiday wear time. The results of the tests and demonstration of the respiration sensing indicate that the adhesive-integrated S4s can provide end users a way for unobtrusive health monitoring. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. A multi-sensor monitoring system of human physiology and daily activities.

    PubMed

    Doherty, Sean T; Oh, Paul

    2012-04-01

    To present the design and pilot test results of a continuous multi-sensor monitoring system of real-world physiological conditions and daily life (activities, travel, exercise, and food consumption), culminating in a Web-based graphical decision-support interface. The system includes a set of wearable sensors wirelessly connected to a "smartphone" with a continuously running software application that compresses and transmits the data to a central server. Sensors include a Global Positioning System (GPS) receiver, electrocardiogram (ECG), three-axis accelerometer, and continuous blood glucose monitor. A food/medicine diary and prompted recall activity diary were also used. The pilot test involved 40 type 2 diabetic patients monitored over a 72-h period. All but three subjects were successfully monitored for the full study period. Smartphones proved to be an effective hub for managing multiple streams of data but required attention to data compression and battery consumption issues. ECG, accelerometer, and blood glucose devices performed adequately as long as subjects wore them. GPS tracking for a full day was feasible, although significant efforts are needed to impute missing data. Activity detection algorithms were successful in identifying activities and trip modes but could benefit by incorporating accelerometer data. The prompted recall diary was an effective tool for augmenting algorithm results, although subjects reported some difficulties with it. The food and medicine diary was completed fully, although end times and medicine dosages were occasionally missing. The unique combination of sensors holds promise for increasing accuracy and reducing burden associated with collecting individual-level activity and physiological data under real-world conditions, but significant data processing issues remain. Such data will provide new opportunities to explore the impacts of human geography and daily lifestyle on health at a fine spatial/temporal scale.

  12. Vasomotor Symptoms Monitoring with a Commercial Activity Tracking Watch

    DTIC Science & Technology

    2017-12-31

    volunteers wearing physiological monitors. The study protocol and written consent form were...available, but similar devices with EDA/GSR sensors are available. Vasomotor symptoms started disrupting the sleep of a woman volunteer on...November 23, 2015, calling attention to their occurrence. After November 23, 2015, the volunteer started personally logging the occurrence of

  13. Evaluation of corn genotypes for drought and heat stress tolerance using physiological measurements and a microcontroller-based monitoring system

    USDA-ARS?s Scientific Manuscript database

    Moisture deficit accompanied by high temperature are major abiotic stress factors that affect corn production in the southern United States, particularly during the reproductive stage of the plant. In evaluating plants for environmental stress tolerance, it is important to monitor changes in their ...

  14. Determination of moisture deficit and heat stress tolerance in corn using physiological measurements and a low-cost microcontroller-based monitoring system

    USDA-ARS?s Scientific Manuscript database

    In the southern United States, corn production encounters moisture deficit coupled with high temperature stress, particularly during the reproductive stage of the plant. In evaluating plants for environmental stress tolerance, it is important to monitor changes in their physical environment under na...

  15. Microsensor Technologies for Plant Growth System Monitoring

    NASA Technical Reports Server (NTRS)

    Kim, Chang-Soo

    2004-01-01

    This document covered the following: a) demonstration of feasibility of microsensor for tube and particulate growth systems; b) Dissolved oxygen; c)Wetness; d) Flexible microfluidic substrate with microfluidic channels and microsensor arrays; e)Dynamic root zone control/monitoring in microgravity; f)Rapid prototyping of phytoremediation; and g) A new tool for root physiology and pathology.

  16. BIOTEX--biosensing textiles for personalised healthcare management.

    PubMed

    Coyle, Shirley; Lau, King-Tong; Moyna, Niall; O'Gorman, Donal; Diamond, Dermot; Di Francesco, Fabio; Costanzo, Daniele; Salvo, Pietro; Trivella, Maria Giovanna; De Rossi, Danilo Emilio; Taccini, Nicola; Paradiso, Rita; Porchet, Jacque-André; Ridolfi, Andrea; Luprano, Jean; Chuzel, Cyril; Lanier, Thierry; Revol-Cavalier, Frdéric; Schoumacker, Sébastien; Mourier, Véronique; Chartier, Isabelle; Convert, Reynald; De-Moncuit, Henri; Bini, Christina

    2010-03-01

    Textile-based sensors offer an unobtrusive method of continually monitoring physiological parameters during daily activities. Chemical analysis of body fluids, noninvasively, is a novel and exciting area of personalized wearable healthcare systems. BIOTEX was an EU-funded project that aimed to develop textile sensors to measure physiological parameters and the chemical composition of body fluids, with a particular interest in sweat. A wearable sensing system has been developed that integrates a textile-based fluid handling system for sample collection and transport with a number of sensors including sodium, conductivity, and pH sensors. Sensors for sweat rate, ECG, respiration, and blood oxygenation were also developed. For the first time, it has been possible to monitor a number of physiological parameters together with sweat composition in real time. This has been carried out via a network of wearable sensors distributed around the body of a subject user. This has huge implications for the field of sports and human performance and opens a whole new field of research in the clinical setting.

  17. Development and evaluation of an ambulatory stress monitor based on wearable sensors.

    PubMed

    Choi, Jongyoon; Ahmed, Beena; Gutierrez-Osuna, Ricardo

    2012-03-01

    Chronic stress is endemic to modern society. However, as it is unfeasible for physicians to continuously monitor stress levels, its diagnosis is nontrivial. Wireless body sensor networks offer opportunities to ubiquitously detect and monitor mental stress levels, enabling improved diagnosis, and early treatment. This article describes the development of a wearable sensor platform to monitor a number of physiological correlates of mental stress. We discuss tradeoffs in both system design and sensor selection to balance information content and wearability. Using experimental signals collected from the wearable sensor, we describe a selected number of physiological features that show good correlation with mental stress. In particular, we propose a new spectral feature that estimates the balance of the autonomic nervous system by combining information from the power spectral density of respiration and heart rate variability. We validate the effectiveness of our approach on a binary discrimination problem when subjects are placed under two psychophysiological conditions: mental stress and relaxation. When used in a logistic regression model, our feature set is able to discriminate between these two mental states with a success rate of 81% across subjects. © 2012 IEEE

  18. Integrated circuits and electrode interfaces for noninvasive physiological monitoring.

    PubMed

    Ha, Sohmyung; Kim, Chul; Chi, Yu M; Akinin, Abraham; Maier, Christoph; Ueno, Akinori; Cauwenberghs, Gert

    2014-05-01

    This paper presents an overview of the fundamentals and state of the-art in noninvasive physiological monitoring instrumentation with a focus on electrode and optrode interfaces to the body, and micropower-integrated circuit design for unobtrusive wearable applications. Since the electrode/optrode-body interface is a performance limiting factor in noninvasive monitoring systems, practical interface configurations are offered for biopotential acquisition, electrode-tissue impedance measurement, and optical biosignal sensing. A systematic approach to instrumentation amplifier (IA) design using CMOS transistors operating in weak inversion is shown to offer high energy and noise efficiency. Practical methodologies to obviate 1/f noise, counteract electrode offset drift, improve common-mode rejection ratio, and obtain subhertz high-pass cutoff are illustrated with a survey of the state-of-the-art IAs. Furthermore, fundamental principles and state-of-the-art technologies for electrode-tissue impedance measurement, photoplethysmography, functional near-infrared spectroscopy, and signal coding and quantization are reviewed, with additional guidelines for overall power management including wireless transmission. Examples are presented of practical dry-contact and noncontact cardiac, respiratory, muscle and brain monitoring systems, and their clinical applications.

  19. Wrist ambulatory monitoring system and smart glove for real time emotional, sensorial and physiological analysis.

    PubMed

    Axisa, F; Gehin, C; Delhomme, G; Collet, C; Robin, O; Dittmar, A

    2004-01-01

    Improvement of the quality and efficiency of the quality of health in medicine, at home and in hospital becomes more and more important Designed to be user-friendly, smart clothes and gloves fit well for such a citizen use and health monitoring. Analysis of the autonomic nervous system using non-invasive sensors provides information for the emotional, sensorial, cognitive and physiological analysis. MARSIAN (modular autonomous recorder system for the measurement of autonomic nervous system) is a wrist ambulatory monitoring and recording system with a smart glove with sensors for the detection of the activity of the autonomic nervous system. It is composed of a "smart tee shirt", a "smart glove", a wrist device and PC which records data. The smart glove is one of the key point of MARSIAN. Complex movements, complex geometry, sensation make smart glove designing a challenge. MARSIAN has a large field of applications and researches (vigilance, behaviour, sensorial analysis, thermal environment for human, cognition science, sport, etc...) in various fields like neurophysiology, affective computing and health monitoring.

  20. Absolute electrical impedance tomography (aEIT) guided ventilation therapy in critical care patients: simulations and future trends.

    PubMed

    Denaï, Mouloud A; Mahfouf, Mahdi; Mohamad-Samuri, Suzani; Panoutsos, George; Brown, Brian H; Mills, Gary H

    2010-05-01

    Thoracic electrical impedance tomography (EIT) is a noninvasive, radiation-free monitoring technique whose aim is to reconstruct a cross-sectional image of the internal spatial distribution of conductivity from electrical measurements made by injecting small alternating currents via an electrode array placed on the surface of the thorax. The purpose of this paper is to discuss the fundamentals of EIT and demonstrate the principles of mechanical ventilation, lung recruitment, and EIT imaging on a comprehensive physiological model, which combines a model of respiratory mechanics, a model of the human lung absolute resistivity as a function of air content, and a 2-D finite-element mesh of the thorax to simulate EIT image reconstruction during mechanical ventilation. The overall model gives a good understanding of respiratory physiology and EIT monitoring techniques in mechanically ventilated patients. The model proposed here was able to reproduce consistent images of ventilation distribution in simulated acutely injured and collapsed lung conditions. A new advisory system architecture integrating a previously developed data-driven physiological model for continuous and noninvasive predictions of blood gas parameters with the regional lung function data/information generated from absolute EIT (aEIT) is proposed for monitoring and ventilator therapy management of critical care patients.

  1. Effect of acetic acid on Saccharomyces carlsbergensis ATCC 6269 batch ethanol production monitored by flow cytometry.

    PubMed

    Freitas, Cláudia; Neves, Elisabete; Reis, Alberto; Passarinho, Paula C; da Silva, Teresa Lopes

    2012-11-01

    Bioethanol produced from lignocellulosic materials has been considered a sustainable alternative fuel. Such type of raw materials have a huge potential, but their hydrolysis into mono-sugars releases toxic compounds such as weak acids, which affect the microorganisms' physiology, inhibiting the growth and ethanol production. Acetic acid (HAc) is the most abundant weak acid in the lignocellulosic materials hydrolysates. In order to understand the physiological changes of Saccharomyces carlsbergensis when fermenting in the presence of different acetic acid (HAc) concentrations, the yeast growth was monitored by multi-parameter flow cytometry at same time that the ethanol production was assessed. The membrane potential stain DiOC(6)(3) fluorescence intensity decreased as the HAc concentration increased, which was attributed to the plasmic membrane potential reduction as a result of the toxic effect of the HAc undissociated form. Nevertheless, the proportion of cells with permeabilized membrane did not increase with the HAc concentration increase. Fermentations ending at lower external pH and higher ethanol concentrations depicted the highest proportions of permeabilized cells and cells with increased reactive oxygen species levels. Flow cytometry allowed monitoring, near real time (at-line), the physiological states of the yeast during the fermentations. The information obtained can be used to optimize culture conditions to improve bioethanol production.

  2. Development of a network system combined with ambulatory and non-conscious physiological measurements for supporting challenged kids - a new proposal of a gait monitoring system for use in rehabilitation.

    PubMed

    Motoi, Kosuke; Oyama, Takanobu; Tanaka, Naoto; Yuji, Tadahiko; Higashi, Yuji; Sagawa, Koichi; Fujimoto, Toshiro; Yamakoshi, Ken-Ichi

    2013-01-01

    Various physiological measurement techniques have been developed to support healthcare and daily living of adult including elderly. However, in light of the rapid growth of the declining birth rate, promotion in care and life support for children are not enough. Especially in rehabilitation for disabled children, i.e., challenged kids, it is important for therapist to evaluate the efficacy of rehabilitation and the health condition. Share of these information with educational, welfare, and government institutions are also needed for accurate life support. Therefore, the quantitative data of the activities and daily health status are helpful. From these viewpoints, we are developing a new network system for monitoring the activities and the health status of children using ambulatory and non-conscious physiological measurements as well as data browse at anytime and anywhere. Firstly, we propose a wearable gait monitoring system to support evaluation for the efficacy of rehabilitation. In this study, the present system can successfully detect the characteristics of postural changes in children with disorder of movement, demonstrating its usefulness and availability to the evaluation for the effect of the brace attached to the subject's lower limb.

  3. Short-term effects of benzalkonium chloride and atrazine on Elodea canadensis using a miniaturised microbioreactor system for an online monitoring of physiologic parameters.

    PubMed

    Vervliet-Scheebaum, Marco; Ritzenthaler, Raphael; Normann, Johannes; Wagner, Edgar

    2008-02-01

    The study evaluated the effects of benzalkonium chloride (BAC) and atrazine on the macrophyte Elodea canadensis (Michaux) using a miniaturised monitoring test system consisting of a microbioreactor of reduced volume and integrated sensors for the online measurement of physiologic parameters, like oxygen production and different parameters of fluorescence. Different concentrations of both chemicals were applied to leaves of E. canadensis and the physiologic endpoints evaluated after 1h. A concentration-dependent reduction of the oxygen production and of the effective quantum yield of energy conversion was recorded. The mini-PAM technique implemented in the presented system allowed for a clear monitoring of the kinetic of BAC and atrazine, showing their distinct mode of action. No observable adverse effects were recorded up to concentrations of 2.5 mg/L and 10 microg/L, for BAC and atrazine, respectively. These values are in accordance with available results in the literature, hence indicating that the microbioreactor test system might be suitable, on the one hand, for the laboratory screening of potential short-term toxicity of contaminants on aquatic plants, and on the other hand, serve as an in situ field biomonitoring system for the rapid detection of pollutants in water.

  4. Novel Technique for Retroperitoneal Implantation of Telemetry Transmitters for Physiologic Monitoring in Göttingen Minipigs (Sus scrofa domesticus)

    PubMed Central

    Willens, Scott; Cox, David M; Braue, Ernest H; Myers, Todd M; Wegner, Matthew D

    2014-01-01

    Telemetric monitoring of physiologic parameters in animal models is a critical component of chemical and biologic agent studies. The long-term collection of neurobehavioral and other physiologic data can require larger telemetry devices. Furthermore, such devices must be implanted in a location that is safe, well-tolerated, and functional. Göttingen minipigs (Sus scrofa domesticus) present an ideal large animal model for chemical agent studies due to their relatively small size, characterized health status, and ease of training and handling. We report an effective approach to implanting a novel device to measure transthoracic impedance to approximate respiratory tidal volume and rate in Suidae. We tested the approach using 24 male Göttingen minipigs. A ventral midline abdominal incision extending from the umbilicus to the prepuce was followed by a paramedian incision of the parietal peritoneum and dorsal blunt dissection to create a retroperitoneal pocket. The device was anchored inside the pocket to the internal abdominal musculature with 3-0 nonabsorbable suture, biopotential leads were routed through the abdominal musculature, and the pocket was closed with 3-0 absorbable suture. Paired biopotential leads were anchored intermuscularly at the level of the seventh rib midway between spine and sternum bilaterally to provide surrogate data for respiratory function. Postoperative recovery and gross pathology findings at necropsy were used to assess safety and refine the surgical procedure. Results demonstrated that this procedure permitted effective monitoring of complex physiologic data, including transthoracic impedance, without negatively affecting the health and behavior of the animals. PMID:25527027

  5. Automated detection of physiologic deterioration in hospitalized patients

    PubMed Central

    Evans, R Scott; Kuttler, Kathryn G; Simpson, Kathy J; Howe, Stephen; Crossno, Peter F; Johnson, Kyle V; Schreiner, Misty N; Lloyd, James F; Tettelbach, William H; Keddington, Roger K; Tanner, Alden; Wilde, Chelbi; Clemmer, Terry P

    2015-01-01

    Objective Develop and evaluate an automated case detection and response triggering system to monitor patients every 5 min and identify early signs of physiologic deterioration. Materials and methods A 2-year prospective, observational study at a large level 1 trauma center. All patients admitted to a 33-bed medical and oncology floor (A) and a 33-bed non-intensive care unit (ICU) surgical trauma floor (B) were monitored. During the intervention year, pager alerts of early physiologic deterioration were automatically sent to charge nurses along with access to a graphical point-of-care web page to facilitate patient evaluation. Results Nurses reported the positive predictive value of alerts was 91–100% depending on erroneous data presence. Unit A patients were significantly older and had significantly more comorbidities than unit B patients. During the intervention year, unit A patients had a significant increase in length of stay, more transfers to ICU (p = 0.23), and significantly more medical emergency team (MET) calls (p = 0.0008), and significantly fewer died (p = 0.044) compared to the pre-intervention year. No significant differences were found on unit B. Conclusions We monitored patients every 5 min and provided automated pages of early physiologic deterioration. This before–after study found a significant increase in MET calls and a significant decrease in mortality only in the unit with older patients with multiple comorbidities, and thus further study is warranted to detect potential confounding. Moreover, nurses reported the graphical alerts provided information needed to quickly evaluate patients, and they felt more confident about their assessment and more comfortable requesting help. PMID:25164256

  6. Heart Rhythm Monitoring in the Constellation Lunar and Launch/Landing EVA Suit: Recommendations from an Expert Panel

    NASA Technical Reports Server (NTRS)

    Scheuring, Richard A.; Hamilton, D.; Jones, J. A.; Alexander, D.

    2008-01-01

    Currently there are several physiological monitoring requirements for Extravehicular Activity (EVA) in the Human-Systems Interface Requirements (HSIR) document, including continuous heart rhythm monitoring. However, it is not known whether heart rhythm monitoring in the lunar surface space suit is a necessary capability for lunar surface operations or in launch/landing suit the event of a cabin depressurization enroute to or from the moon. Methods: Current US astronaut corps demographic information was provided to an expert panel of cardiovascular medicine experts, including specialists in electrophysiology, exercise physiology, interventional cardiology and arrhythmia. This information included averages for male/female age, body mass index (BMI), blood pressure, cholesterol, inflammatory markers, echocardiogram, ranges for coronary artery calcium (CAC) scores for long duration astronauts, and ranges for heart rate (HR) and metabolic (MET) rates obtained during microgravity and lunar EVA. Results: The panel determined that no uncontrolled hazard was likely to occur in the suit during lunar surface or contingency microgravity ops that would require ECG monitoring in the highly screened US astronaut population. However having the capability for rhythm monitoring inside the vehicle (IVA) was considered critical to manage an astronaut in distress. Discussion: Heart rate (HR) monitoring alone allows effective monitoring of astronaut health and function. Consequently, electrocardiographic (ECG) monitoring capability as a clinical tool is not essential in the lunar or launch/landing space suit. However, the panel considered that rhythm monitoring could be useful in certain clinical situations, it was not considered required for safe operations. Also, lunar vehicles should be required to have ECG monitoring capability with a minimum of 5-lead ECG (derived 12- lead) for IVA medical assessments.

  7. Seasonal assessment of biological indices, bioaccumulation, and bioavailability of heavy metals in sea urchins Paracentrotus lividus from Algerian west coast, applied to environmental monitoring.

    PubMed

    Rouane-Hacene, Omar; Boutiba, Zitouni; Benaissa, Meriem; Belhaouari, Benkhedda; Francour, Patrice; Guibbolini-Sabatier, Marielle E; Faverney, Christine Risso-De

    2018-04-01

    The aim of the present work was to extend our knowledge on the variability of trace metals in sea urchin tissues, focusing on seasonal fluctuations (2010 February for "winter," May for "spring," August for "summer," November for "autumn") in the three different sampling sites of Algerian west coast (Oran Harbor (S1), Ain Defla (S2), and Hadjaj (belonging to Mostaganem City S3)). For this purpose, the bioavailability (metal indices) and bioaccumulation (metal concentrations in soft tissues) of heavy metals (Zn, Cu, Pb, and Cd), the physiological characteristics (e.g., biological indices such as condition index (CI), repletion index (RI), gonad index (GI)), and the biometric parameters (diameter (D) and the height (H)) of sea urchins Paracentrotus lividus were assessed and related to seasons and sites. To investigate the metal bioavailability to sea urchins more precisely, the metal indices were used as a reliable tool in the present work, instead of the metal concentrations only. The interest to standardize metal concentrations with the weight of the urchin test is to overcome the metal burden variations in the soft tissues of urchin related to the seasonal weight changes of the soft body of animal. We evidence that the most contaminated sites were S1 and S2. Furthermore, it should be noted that the bioavailability of metals, corresponding to the values of metal indices, is also more pronounced in S1 and S2 compared to that measured in S3. Thus, a correlation is observed between seasonal metal content in urchin tissues from the three sites and the corresponding metal indices. The high metal concentrations were obtained during the period when RI and CI were highest. So, it appears that the bioaccumulation of metals in sea urchins of the three sites studied is significantly influenced by the reproductive cycle and diet, feeding activity, and physiological state of these organisms. We noticed that the sea urchins from the sites S1 and S2 were small in size. It is probable that these animals, whose internal tissues contained high concentrations of metals, have been exposed to metal pollution, which might have affected both their growth and altered their physiological capacity. This approach is very original and might be used in the monitoring of the quality of coastal waters, and the present work provided a useful data set for Mediterranean monitoring network.

  8. Standards 101; the ASA standards program

    NASA Astrophysics Data System (ADS)

    Schomer, Paul D.

    2002-11-01

    ASA supports the development of standards by serving as the secretariat for standards committees of the American National Standards Institute (ANSI). The program is organized through four ANSI technical committees (S1, S2, S3, and S12) and one administrative committee (ASACOS). S1 deals with physical acoustics, S2 deals with shock and vibration, S3 deals with physiological and psychological acoustics, and S12 deals with noise. ASACOS is the ASA Committee on Standards. The program has three primary tasks: (1) the development of National Standards (ANSI Standards), (2) the national adoption of an international standard (ANSI NAIS Standards), (3) providing the USA input to the development of International Standards (ISO and IEC Standards). At every level the main work is accomplished in Working Groups (WG) that are ''staffed'' by hundreds of volunteers--mainly ASA members from its various technical committees such as Noise, Physical Acoustics, Architectural Acoustics, Psychological and Physiological Acoustics, etc. Overall, the Standards Program involves more ASA members than does any other single function of the Society except meetings and it is the biggest outreach function of ASA affecting the health, welfare, and economic well-being of large segments of the population, the business and industrial community, and government at all levels.

  9. Standards 101: The ASA Standards program

    NASA Astrophysics Data System (ADS)

    Schomer, Paul

    2004-05-01

    ASA serves as a standards developer under the auspices of the American National Standards Institute (ANSI). The Standards Program is organized through four technical committees (S1, S2, S3, and S12) and one administrative committee (ASACOS). S1 deals with physical acoustics, S2 deals with shock and vibration, S3 deals with physiological and psychological acoustics and S12 deals with noise. ASACOS is the ASA Committee on Standards. The program has three primary tasks: (1) development of national standards (ANSI Standards), (2) national adoption of international standards (ANSI NAIS Standards), (3) providing the USA input to the development of international standards (ISO and IEC Standards). At every level the main work is accomplished in Working Groups (WG) that are staffed by hundreds of volunteers, mainly ASA members from its various technical committees such as Noise, Physical Acoustics, Architectural Acoustics, Physiological and Psychological Acoustics, etc. Overall, the Standards Program involves more ASA members than does any other single function of the society except meetings. It is the biggest outreach function of ASA affecting the health, welfare, and economic well-being of large sectors of society. It is a main way the ASA diffuses the knowledge of acoustics and its practical application, perhaps the main way.

  10. Battery-free, stretchable optoelectronic systems for wireless optical characterization of the skin.

    PubMed

    Kim, Jeonghyun; Salvatore, Giovanni A; Araki, Hitoshi; Chiarelli, Antonio M; Xie, Zhaoqian; Banks, Anthony; Sheng, Xing; Liu, Yuhao; Lee, Jung Woo; Jang, Kyung-In; Heo, Seung Yun; Cho, Kyoungyeon; Luo, Hongying; Zimmerman, Benjamin; Kim, Joonhee; Yan, Lingqing; Feng, Xue; Xu, Sheng; Fabiani, Monica; Gratton, Gabriele; Huang, Yonggang; Paik, Ungyu; Rogers, John A

    2016-08-01

    Recent advances in materials, mechanics, and electronic device design are rapidly establishing the foundations for health monitoring technologies that have "skin-like" properties, with options in chronic (weeks) integration with the epidermis. The resulting capabilities in physiological sensing greatly exceed those possible with conventional hard electronic systems, such as those found in wrist-mounted wearables, because of the intimate skin interface. However, most examples of such emerging classes of devices require batteries and/or hard-wired connections to enable operation. The work reported here introduces active optoelectronic systems that function without batteries and in an entirely wireless mode, with examples in thin, stretchable platforms designed for multiwavelength optical characterization of the skin. Magnetic inductive coupling and near-field communication (NFC) schemes deliver power to multicolored light-emitting diodes and extract digital data from integrated photodetectors in ways that are compatible with standard NFC-enabled platforms, such as smartphones and tablet computers. Examples in the monitoring of heart rate and temporal dynamics of arterial blood flow, in quantifying tissue oxygenation and ultraviolet dosimetry, and in performing four-color spectroscopic evaluation of the skin demonstrate the versatility of these concepts. The results have potential relevance in both hospital care and at-home diagnostics.

  11. COMPOSE: Using temporal patterns for interpreting wearable sensor data with computer interpretable guidelines.

    PubMed

    Urovi, V; Jimenez-Del-Toro, O; Dubosson, F; Ruiz Torres, A; Schumacher, M I

    2017-02-01

    This paper describes a novel temporal logic-based framework for reasoning with continuous data collected from wearable sensors. The work is motivated by the Metabolic Syndrome, a cluster of conditions which are linked to obesity and unhealthy lifestyle. We assume that, by interpreting the physiological parameters of continuous monitoring, we can identify which patients have a higher risk of Metabolic Syndrome. We define temporal patterns for reasoning with continuous data and specify the coordination mechanisms for combining different sets of clinical guidelines that relate to this condition. The proposed solution is tested with data provided by twenty subjects, which used sensors for four days of continuous monitoring. The results are compared to the gold standard. The novelty of the framework stands in extending a temporal logic formalism, namely the Event Calculus, with temporal patterns. These patterns are helpful to specify the rules for reasoning with continuous data and in combining new knowledge into one consistent outcome that is tailored to the patient's profile. The overall approach opens new possibilities for delivering patient-tailored interventions and educational material before the patients present the symptoms of the disease. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. An experimental examination of the effort-reward imbalance model of occupational stress: Increased financial reward is related to reduced stress physiology.

    PubMed

    Landolt, Kathleen; O'Donnell, Emma; Hazi, Agnes; Dragano, Nico; Wright, Bradley J

    2017-04-01

    Effort-reward imbalance in the workplace is linked to a variety of negative health and organisational outcomes, but it has rarely been assessed experimentally. We manipulated reward (while keeping effort constant) in a within-subjects design with female participants (N=60) who were randomly assigned to high and standard reward conditions within a simulated office environment. Self-report, behavioural (task performance), and physiological (heart rate variability, salivary alpha amylase) measures assessed the impact of increased financial reward. Participants reported increased perceptions of reward, performed moderately better on the task, and were less physiologically reactive in the high reward versus the standard condition. These findings highlight the importance of assessing both subjective self-reports of stress together with objective physiological measures of stress, and suggest that increasing monetary rewards has the potential to decrease stress physiological reactivity, and in turn, reduce the risk of ill-health in employees, and may also positively influence task efficacy. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Theoretical analysis of the mechanisms of a gender differentiation in the propensity for orthostatic intolerance after spaceflight

    PubMed Central

    2010-01-01

    Background A tendency to develop reentry orthostasis after a prolonged exposure to microgravity is a common problem among astronauts. The problem is 5 times more prevalent in female astronauts as compared to their male counterparts. The mechanisms responsible for this gender differentiation are poorly understood despite many detailed and complex investigations directed toward an analysis of the physiologic control systems involved. Methods In this study, a series of computer simulation studies using a mathematical model of cardiovascular functioning were performed to examine the proposed hypothesis that this phenomenon could be explained by basic physical forces acting through the simple common anatomic differences between men and women. In the computer simulations, the circulatory components and hydrostatic gradients of the model were allowed to adapt to the physical constraints of microgravity. After a simulated period of one month, the model was returned to the conditions of earth's gravity and the standard postflight tilt test protocol was performed while the model output depicting the typical vital signs was monitored. Conclusions The analysis demonstrated that a 15% lowering of the longitudinal center of gravity in the anatomic structure of the model was all that was necessary to prevent the physiologic compensatory mechanisms from overcoming the propensity for reentry orthostasis leading to syncope. PMID:20298577

  14. National survey of cardiologists' standard of practice for continuous ST-segment monitoring.

    PubMed

    Sandau, Kristin E; Sendelbach, Sue; Frederickson, Joel; Doran, Karen

    2010-03-01

    Continuous ST-segment monitoring can be used to detect early and transient cardiac ischemia. The American Heart Association and American Association of Critical-Care Nurses recommend its use among specific patients, but such monitoring is routine practice in only about half of US hospitals. To determine cardiologists' awareness and practice standards regarding continuous ST-segment monitoring and the physicians' perceptions of appropriate patient selection, benefits and barriers, and usefulness of this technology. An electronic survey was sent to a random sample of 915 US cardiologists from a pool of 4985 certified cardiologists. Of 200 responding cardiologists, 55% were unaware of the consensus guidelines. Of hospitals where respondents admitted patients, 49% had a standard of practice for using continuous ST-segment monitoring for cardiac patients. Most cardiologists agreed or strongly agreed that patients in the cardiovascular laboratory (87.5%) and intensive care unit (80.5%) should have such monitoring. Cardiologists routinely ordered ST monitoring for patients with acute coronary syndrome (67%) and after percutaneous coronary intervention (60%). The primary factor associated with higher perceptions for benefits, clinical usefulness, and past use of continuous ST-segment monitoring was whether or not hospitals in which cardiologists practiced had a standard of practice for using this monitoring. A secondary factor was awareness of published consensus guidelines for such monitoring. Respondents (55%) were unaware of published monitoring guidelines. Hospital leaders could raise awareness by multidisciplinary review of evidence and possibly incorporating continuous ST-segment monitoring into hospitals' standards of practice.

  15. Life Sciences Research and Development Opportunities During Suborbital Space Flight

    NASA Technical Reports Server (NTRS)

    Davis, Jeffrey R.

    2010-01-01

    Suborbital space platforms provide a unique opportunity for Space Life Sciences in the next few years. The opportunities include: physiological characterization of the first few minutes of space flight; evaluation of a wide-variety of medical conditions during periods of hyper and hypo-gravity through physiological monitoring; and evaluation of new biomedical and environmental health technologies under hyper and hypo-gravity conditions

  16. Integrating the effects of salinity on the physiology of the eastern oyster, Crassostrea virginica, in the northern Gulf of Mexico through a Dynamic Energy Budget model

    USGS Publications Warehouse

    Lavaud, Romain; LaPeyre, Megan K.; Casas, Sandra M.; Bacher, C.; La Peyre, Jerome F.

    2017-01-01

    We present a Dynamic Energy Budget (DEB) model for the eastern oyster, Crassostrea virginica, which enables the inclusion of salinity as a third environmental variable, on top of the standard foodr and temperature variables. Salinity changes have various effects on the physiology of oysters, potentially altering filtration and respiration rates, and ultimately impacting growth, reproduction and mortality. We tested different hypotheses as to how to include these effects in a DEB model for C. virginica. Specifically, we tested two potential mechanisms to explain changes in oyster shell growth (cm), tissue dry weight (g) and gonad dry weight (g) when salinity moves away from the ideal range: 1) a negative effect on filtration rate and 2) an additional somatic maintenance cost. Comparative simulations of shell growth, dry tissue biomass and dry gonad weight in two monitored sites in coastal Louisiana experiencing salinity from 0 to 28 were statistically analyzed to determine the best hypothesis. Model parameters were estimated through the covariation method, using literature data and a set of specifically designed ecophysiological experiments. The model was validated through independent field studies in estuaries along the northern Gulf of Mexico. Our results suggest that salinity impacts C. virginica’s energy budget predominantly through effects on filtration rate. With an overwhelming number of environmental factors impacting organisms, and increasing exposure to novel and extreme conditions, the mechanistic nature of the DEB model with its ability to incorporate more than the standard food and temperature variables provides a powerful tool to verify hypotheses and predict individual organism performance across a range of conditions.

  17. The Power of Physiology in Changing Landscapes: Considerations for the Continued Integration of Conservation and Physiology.

    PubMed

    Madliger, Christine L; Love, Oliver P

    2015-10-01

    The growing field of conservation physiology applies a diversity of physiological traits (e.g., immunological, metabolic, endocrine, and nutritional traits) to understand and predict organismal, population, and ecosystem responses to environmental change and stressors. Although the discipline of conservation physiology is gaining momentum, there is still a pressing need to better translate knowledge from physiology into real-world tools. The goal of this symposium, ‘‘Physiology in Changing Landscapes: An Integrative Perspective for Conservation Biology’’, was to highlight that many current investigations in ecological, evolutionary, and comparative physiology are necessary for understanding the applicability of physiological measures for conservation goals, particularly in the context of monitoring and predicting the health, condition, persistence, and distribution of populations in the face of environmental change. Here, we outline five major investigations common to environmental and ecological physiology that can contribute directly to the progression of the field of conservation physiology: (1) combining multiple measures of physiology and behavior; (2) employing studies of dose–responses and gradients; (3) combining a within-individual and population-level approach; (4) taking into account the context-dependency of physiological traits; and (5) linking physiological variables with fitness metrics. Overall, integrative physiologists have detailed knowledge of the physiological systems that they study; however, communicating theoretical and empirical knowledge to conservation biologists and practitioners in an approachable and applicable way is paramount to the practical development of physiological tools that will have a tangible impact for conservation.

  18. Stretchable inorganic nanomembrane electronics for healthcare devices

    NASA Astrophysics Data System (ADS)

    Kim, Dae-Hyeong; Son, Donghee; Kim, Jaemin

    2015-05-01

    Flexible or stretchable electronic devices for healthcare technologies have attracted much attention in terms of usefulness to assist doctors in their operating rooms and to monitor patients' physical conditions for a long period of time. Each device to monitor the patients' physiological signals real-time, such as strain, pressure, temperature, and humidity, etc. has been reported recently. However, their limitations are found in acquisition of various physiological signals simultaneously because all the functions are not assembled in one skin-like electronic system. Here, we describe a skin-like, multi-functional healthcare system, which includes single crystalline silicon nanomembrane based sensors, nanoparticle-integrated non-volatile memory modules, electro-resistive thermal actuators, and drug delivery. Smart prosthetics coupled with therapeutic electronic system would provide new approaches to personalized healthcare.

  19. Technical Testing of the Wristwatch Size Automatic Physiological and Environmental Monitor (WAPEM): Laboratory and Outdoor Evaluations of Environmental Sensors Performance

    DTIC Science & Technology

    2004-03-01

    relative humidity (RH), ambient temperature (Ta), solar radiation (SR), and human activity in a small, water- resistant, durable enclosure. It is fitted...temperature, SR, and human activity . The activity channel is designed to function for sleep scoring (ZGM), as well as monitoring daytime activity with the

  20. Novel approaches for integrating chemistry, transcriptomics and physiology of caged fish to examine the impacts of contaminants of emerging concern.

    EPA Science Inventory

    Product Description:Many chemicals are being detected in the Great Lakes watershed, but it is not always clear which of these may be of concern and should be prioritized for monitoring or management. The current study investigates the use of novel biologically-based monitoring me...

  1. Challenges of ambulatory physiological sensing.

    PubMed

    Healey, Jennifer

    2004-01-01

    Applications for ambulatory monitoring span the spectrum from fitness optimization to cardiac defibrillation. This range of applications is associated with a corresponding range of required detection accuracies and a range of inconvenience and discomfort that wearers are willing to tolerate. This paper describes a selection of physiological sensors and how they might best be worn in the unconstrained ambulatory environment to provide the most robust measurements and the greatest comfort to the wearer. Using wireless mobile computing devices, it will be possible to record, analyze and respond to changes in the wearers' physiological signals in real time using these sensors.

  2. Inter-rater Agreement of Clinicians' Treatment Recommendations Based on Modified Barium Swallow Study Reports.

    PubMed

    Slovarp, Laurie; Danielson, Jennifer; Liss, Julie

    2018-06-07

    The modified barium swallow study (MBSS) is a commonly used radiographic procedure for diagnosis and treatment of swallowing disorders. Despite attempts by dysphagia specialists to standardize the MBSS, most institutions have not adopted such standardized procedures. High variability of assessment patterns arguably contribute to variability of treatment recommendations made from diagnostic information derived from the MBSS report. An online survey was distributed to speech-language pathologists (SLPs) participating in American Speech Language Hearing Association (ASHA) listservs. Sixty-three SLPs who treat swallowing disorders participated. Participating SLPs reviewed two MBSS reports and chose physiologic treatment targets (e.g., tongue base retraction) based on each report. One report primarily contained symptomatology (e.g., aspiration, pharyngeal residue) with minimal information on impaired physiology (e.g., laryngeal incompetence, reduced hyolaryngeal elevation/excursion). In contrast, the second report contained a clear description of impaired physiology to explain the dysphagia symptoms. Fleiss kappa coefficients were used to analyze inter-rater agreement across the high and low physiology report types. Results revealed significantly higher inter-rater agreement across clinicians when reviewing reports with clear explanation(s) of physiologic impairment relative to reports that primarily focused on symptomatology. Clinicians also reported significantly greater satisfaction and treatment confidence following review of reports with clear description(s) of impaired physiology.

  3. Evaluation of a strapless heart rate monitor during simulated flight tasks.

    PubMed

    Wang, Zhen; Fu, Shan

    2016-01-01

    Pilots are under high task demands during flight. Monitoring pilot's physiological status is very important in the evaluation of pilot's workload and flight safety. Recently, physiological status monitor (PSM) has been embedded into a watch that can be used without a conventional chest strap. This makes it possible to unobtrusively monitor, log and transmit pilot's physiological measurements such as heart rate (HR) during flight tasks. The purpose of this study is to validate HR recorded by a strapless heart rate watch against criterion ECG-derived HR. Ten commercial pilots (mean ± SD : age: 39.1 ± 7.8 years; total flight hours 7173.2 ± 5270.9 hr) performed three routinely trained flight tasks in a full flight simulator: wind shear go-around (WG), takeoff and climb (TC), and hydraulic failure (HF). For all tasks combined (overall) and for each task, differences between the heart rate watch measurements and the criterion data were small (mean difference [95% CI]: overall: -0.71 beats/min [-0.85, -0.57]; WG: -0.90 beats/min [-1.15, -0.65]; TC: -0.69 beats/min [-0.98, -0.40]; HF: -0.61 beats/min [-0.80, -0.42]). There were high correlations between the heart rate watch measurements and the ECG-derived HR for all tasks (r ≥ 0.97, SEE < 3). Bland-Altman plots also show high agreements between the watch measurements and the criterion HR. These results suggest that the strapless heart rate watch provides valid measurements of HR during simulated flight tasks and could be a useful tool for pilot workload evaluation.

  4. Collection of annotated data in a clinical validation study for alarm algorithms in intensive care--a methodologic framework.

    PubMed

    Siebig, Sylvia; Kuhls, Silvia; Imhoff, Michael; Langgartner, Julia; Reng, Michael; Schölmerich, Jürgen; Gather, Ursula; Wrede, Christian E

    2010-03-01

    Monitoring of physiologic parameters in critically ill patients is currently performed by threshold alarm systems with high sensitivity but low specificity. As a consequence, a multitude of alarms are generated, leading to an impaired clinical value of these alarms due to reduced alertness of the intensive care unit (ICU) staff. To evaluate a new alarm procedure, we currently generate a database of physiologic data and clinical alarm annotations. Data collection is taking place at a 12-bed medical ICU. Patients with monitoring of at least heart rate, invasive arterial blood pressure, and oxygen saturation are included in the study. Numerical physiologic data at 1-second intervals, monitor alarms, and alarm settings are extracted from the surveillance network. Bedside video recordings are performed with network surveillance cameras. Based on the extracted data and the video recordings, alarms are clinically annotated by an experienced physician. The alarms are categorized according to their technical validity and clinical relevance by a taxonomy system that can be broadly applicable. Preliminary results showed that only 17% of the alarms were classified as relevant, and 44% were technically false. The presented system for collecting real-time bedside monitoring data in conjunction with video-assisted annotations of clinically relevant events is the first allowing the assessment of 24-hour periods and reduces the bias usually created by bedside observers in comparable studies. It constitutes the basis for the development and evaluation of "smart" alarm algorithms, which may help to reduce the number of alarms at the ICU, thereby improving patient safety. Copyright 2010 Elsevier Inc. All rights reserved.

  5. Validation of Procedures for Monitoring Crewmember Immune Function SDBI-1900, SMO-015 - Integrated Immune

    NASA Technical Reports Server (NTRS)

    Crucian, Brian; Stowe, Raymond; Mehta, Satish; Uchakin, Peter; Nehlsen-Cannarella, Sandra; Morukov, Boris; Pierson, Duane; Sams, Clarence

    2007-01-01

    There is ample evidence to suggest that space flight leads to immune system dysregulation. This may be a result of microgravity, confinement, physiological stress, radiation, environment or other mission-associated factors. The clinical risk from prolonged immune dysregulation during space flight are not yet determined, but may include increased incidence of infection, allergy, hypersensitivity, hematological malignancy or altered wound healing. Each of the clinical events resulting from immune dysfunction has the potential to impact mission critical objectives during exploration-class missions. To date, precious little in-flight immune data has been generated to assess this phenomenon. The majority of recent flight immune studies have been post-flight assessments, which may not accurately reflect the in-flight condition. There are no procedures currently in place to monitor immune function or its effect on crew health. The objective of this Supplemental Medical Objective (SMO) is to develop and validate an immune monitoring strategy consistent with operational flight requirements and constraints. This SMO will assess the clinical risks resulting from the adverse effects of space flight on the human immune system and will validate a flight-compatible immune monitoring strategy. Characterization of the clinical risk and the development of a monitoring strategy are necessary prerequisite activities prior to validating countermeasures. This study will determine, to the best level allowed by current technology, the in-flight status of crewmembers immune system. Pre-flight, in-flight and post-flight assessments of immune status, immune function, viral reactivation and physiological stress will be performed. The in-flight samples will allow a distinction between legitimate in-flight alterations and the physiological stresses of landing and readaptation which are believed to alter landing day assessments. The overall status of the immune system during flight (activation, deficiency, dysregulation) and the response of the immune system to specific latent virus reactivation (known to occur during space flight) will be thoroughly assessed. Following completion of the SMO the data will be evaluated to determine the optimal set of assays for routine monitoring of crewmember immune system function, should the clinical risk warrant such monitoring.

  6. A Stable Bacterial Peroxidase with Novel Halogenating Activity and an Autocatalytically Linked Heme Prosthetic Group*

    PubMed Central

    Auer, Markus; Gruber, Clemens; Bellei, Marzia; Pirker, Katharina F.; Zamocky, Marcel; Kroiss, Daniela; Teufer, Stefan A.; Hofbauer, Stefan; Soudi, Monika; Battistuzzi, Gianantonio; Furtmüller, Paul G.; Obinger, Christian

    2013-01-01

    Reconstructing the phylogenetic relationships of the main evolutionary lines of the mammalian peroxidases lactoperoxidase and myeloperoxidase revealed the presence of novel bacterial heme peroxidase subfamilies. Here, for the first time, an ancestral bacterial heme peroxidase is shown to possess a very high bromide oxidation activity (besides conventional peroxidase activity). The recombinant protein allowed monitoring of the autocatalytic peroxide-driven formation of covalent heme to protein bonds. Thereby, the high spin ferric rhombic heme spectrum became similar to lactoperoxidase, the standard reduction potential of the Fe(III)/Fe(II) couple shifted to more positive values (−145 ± 10 mV at pH 7), and the conformational and thermal stability of the protein increased significantly. We discuss structure-function relationships of this new peroxidase in relation to its mammalian counterparts and ask for its putative physiological role. PMID:23918925

  7. Managing children with chronic myeloid leukaemia (CML): recommendations for the management of CML in children and young people up to the age of 18 years.

    PubMed

    de la Fuente, Josu; Baruchel, André; Biondi, Andrea; de Bont, Eveline; Dresse, Marie-Françoise; Suttorp, Meinolf; Millot, Frédéric

    2014-10-01

    Chronic myeloid leukaemia in children and young people is a relatively rare form of leukaemia that shows increased incidence with age and some evidence suggests that the molecular basis differs from that in adults. Significant advances in targeted therapy with the development and use in children of tyrosine kinase inhibitors and the ability to monitor and understand the prognostic significance of minimal residual disease by standardized molecular techniques has shifted the management of this condition from bone marrow transplantation as the main therapeutic modality to individualized treatment for each patient based on achieving specific milestones. The physiological changes occurring during childhood, particularly those affecting growth and development and the long-term use of treatment, pose specific challenges in this age group, which we are only beginning to understand. © 2014 John Wiley & Sons Ltd.

  8. Biomarkers of Aging: From Function to Molecular Biology

    PubMed Central

    Wagner, Karl-Heinz; Cameron-Smith, David; Wessner, Barbara; Franzke, Bernhard

    2016-01-01

    Aging is a major risk factor for most chronic diseases and functional impairments. Within a homogeneous age sample there is a considerable variation in the extent of disease and functional impairment risk, revealing a need for valid biomarkers to aid in characterizing the complex aging processes. The identification of biomarkers is further complicated by the diversity of biological living situations, lifestyle activities and medical treatments. Thus, there has been no identification of a single biomarker or gold standard tool that can monitor successful or healthy aging. Within this short review the current knowledge of putative biomarkers is presented, focusing on their application to the major physiological mechanisms affected by the aging process including physical capability, nutritional status, body composition, endocrine and immune function. This review emphasizes molecular and DNA-based biomarkers, as well as recent advances in other biomarkers such as microRNAs, bilirubin or advanced glycation end products. PMID:27271660

  9. Comparison of Digital Rectal and Microchip Transponder Thermometry in Ferrets (Mustela putorius furo)

    PubMed Central

    Maxwell, Branden M; Brunell, Marla K; Olsen, Cara H; Bentzel, David E

    2016-01-01

    Body temperature is a common physiologic parameter measured in both clinical and research settings, with rectal thermometry being implied as the ‘gold standard.’ However, rectal thermometry usually requires physical or chemical restraint, potentially causing falsely elevated readings due to animal stress. A less stressful method may eliminate this confounding variable. The current study compared 2 types of digital rectal thermometers—a calibrated digital thermometer and a common digital thermometer—with an implantable subcutaneous transponder microchip. Microchips were implanted subcutaneously between the shoulder blades of 16 ferrets (8 male, 8 female), and temperatures were measured twice from the microchip reader and once from each of the rectal thermometers. Results demonstrated the microchip temperature readings had very good to good correlation and agreement to those from both of the rectal thermometers. This study indicates that implantable temperature-sensing microchips are a reliable alternative to rectal thermometry for monitoring body temperature in ferrets. PMID:27177569

  10. The cerebral hemodynamics of normotensive hypovolemia during lower-body negative pressure

    NASA Technical Reports Server (NTRS)

    Giller, C. A.; Levine, B. D.; Meyer, Y.; Buckey, J. C.; Lane, L. D.; Borchers, D. J.

    1992-01-01

    Although severe hypovolemia can lead to hypotension and neurological decline, many patients with neurosurgical disorders experience a significant hypovolemia while autonomic compensatory mechanisms maintain a normal blood pressure. To assess the effects of normotensive hypovolemia upon cerebral hemodynamics, transcranial Doppler ultrasound monitoring of 13 healthy volunteers was performed during graded lower-body negative pressure of up to -50 mm Hg, an accepted laboratory model for reproducing the physiological effects of hypovolemia. Middle cerebral artery flow velocity declined by 16% +/- 4% (mean +/- standard error of the mean) and the ratio between transcranial Doppler ultrasound pulsatility and systemic pulsatility rose 22% +/- 8%, suggesting cerebral small-vessel vasoconstriction in response to the sympathetic activation unmasked by lower-body negative pressure. This vasoconstriction may interfere with the autoregulatory response to a sudden fall in blood pressure, and may explain the common observation of neurological deficit during hypovolemia even with a normal blood pressure.

  11. PhysioDroid: Combining Wearable Health Sensors and Mobile Devices for a Ubiquitous, Continuous, and Personal Monitoring

    PubMed Central

    Villalonga, Claudia; Damas, Miguel

    2014-01-01

    Technological advances on the development of mobile devices, medical sensors, and wireless communication systems support a new generation of unobtrusive, portable, and ubiquitous health monitoring systems for continuous patient assessment and more personalized health care. There exist a growing number of mobile apps in the health domain; however, little contribution has been specifically provided, so far, to operate this kind of apps with wearable physiological sensors. The PhysioDroid, presented in this paper, provides a personalized means to remotely monitor and evaluate users' conditions. The PhysioDroid system provides ubiquitous and continuous vital signs analysis, such as electrocardiogram, heart rate, respiration rate, skin temperature, and body motion, intended to help empower patients and improve clinical understanding. The PhysioDroid is composed of a wearable monitoring device and an Android app providing gathering, storage, and processing features for the physiological sensor data. The versatility of the developed app allows its use for both average users and specialists, and the reduced cost of the PhysioDroid puts it at the reach of most people. Two exemplary use cases for health assessment and sports training are presented to illustrate the capabilities of the PhysioDroid. Next technical steps include generalization to other mobile platforms and health monitoring devices. PMID:25295301

  12. PhysioDroid: combining wearable health sensors and mobile devices for a ubiquitous, continuous, and personal monitoring.

    PubMed

    Banos, Oresti; Villalonga, Claudia; Damas, Miguel; Gloesekoetter, Peter; Pomares, Hector; Rojas, Ignacio

    2014-01-01

    Technological advances on the development of mobile devices, medical sensors, and wireless communication systems support a new generation of unobtrusive, portable, and ubiquitous health monitoring systems for continuous patient assessment and more personalized health care. There exist a growing number of mobile apps in the health domain; however, little contribution has been specifically provided, so far, to operate this kind of apps with wearable physiological sensors. The PhysioDroid, presented in this paper, provides a personalized means to remotely monitor and evaluate users' conditions. The PhysioDroid system provides ubiquitous and continuous vital signs analysis, such as electrocardiogram, heart rate, respiration rate, skin temperature, and body motion, intended to help empower patients and improve clinical understanding. The PhysioDroid is composed of a wearable monitoring device and an Android app providing gathering, storage, and processing features for the physiological sensor data. The versatility of the developed app allows its use for both average users and specialists, and the reduced cost of the PhysioDroid puts it at the reach of most people. Two exemplary use cases for health assessment and sports training are presented to illustrate the capabilities of the PhysioDroid. Next technical steps include generalization to other mobile platforms and health monitoring devices.

  13. Monitoring Dopamine ex Vivo during Electrical Stimulation Using Liquid-Microjunction Surface Sampling.

    PubMed

    Gill, Emily L; Marks, Megan; Yost, Richard A; Vedam-Mai, Vinata; Garrett, Timothy J

    2017-12-19

    Liquid-microjunction surface sampling (LMJ-SS) is an ambient ionization technique based on the continuous flow of solvent using an in situ microextraction device in which solvent moves through the probe, drawing in the analytes in preparation for ionization using an electrospray ionization source. However, unlike traditional mass spectrometry (MS) techniques, it operates under ambient pressure and requires no sample preparation, thereby making it ideal for rapid sampling of thicker tissue sections for electrophysiological and other neuroscientific research studies. Studies interrogating neural synapses, or a specific neural circuit, typically employ thick, ex vivo tissue sections maintained under near-physiological conditions to preserve tissue viability and maintain the neural networks. Deep brain stimulation (DBS) is a surgical procedure used to treat the neurological symptoms that are associated with certain neurodegenerative and neuropsychiatric diseases. Parkinson's disease (PD) is a neurological disorder which is commonly treated with DBS therapy. PD is characterized by the degeneration of dopaminergic neurons in the substantia nigra pars compacta portion of the brain. Here, we demonstrate that the LMJ-SS methodology can provide a platform for ex vivo analysis of the brain during electrical stimulation, such as DBS. We employ LMJ-SS in the ex vivo analysis of mouse brain tissue for monitoring dopamine during electrical stimulation of the striatum region. The mouse brain tissue was sectioned fresh post sacrifice and maintained in artificial cerebrospinal fluid to create near-physiological conditions before direct sampling using LMJ-SS. A selection of metabolites, including time-sensitive metabolites involved in energy regulation in the brain, were identified using standards, and the mass spectral database mzCloud was used to assess the feasibility of the methodology. Thereafter, the intensity of m/z 154 corresponding to protonated dopamine was monitored before and after electrical stimulation of the striatum region, showing an increase in signal directly following a stimulation event. Dopamine is the key neurotransmitter implicated in PD, and although electrochemical detectors have shown such increases in dopamine post-DBS, this is the first study to do so using MS methodologies.

  14. Occupational Survey Report. AFSC 4M0X1 Aerospace Physiology

    DTIC Science & Technology

    2002-05-01

    Chamber NCOIC Job Hyperbaric Chamber Specialist Job • Perform Type 2, 4 and 1 chamber flights • Perform inside observer duties during hypobaric ...78% Hyperbaric Chamber Specialist Independent Job 4% Not Grouped 2% U2 Aerospace Physiology Cluster 10% Job Structure Sample size: 168 Aerospace...Altitude Chamber Cluster (N=130) Hypobaric Chamber Instructor/Monitor Job HAAMS Job Altitude Chamber Apprentice Job 78% UPT Parasail Job Altitude

  15. Understanding the Psycho-Physiological Implications of Interaction With a Virtual Reality-Based System in Adolescents With Autism: A Feasibility Study.

    PubMed

    Kuriakose, Selvia; Lahiri, Uttama

    2015-07-01

    Individuals with Autism are characterized by deficits in socialization and communication. In recent years several assistive technologies, e.g., Virtual Reality (VR), have been investigated to address the socialization deficits in these individuals. Presently available VR-based systems address various aspects of social communication in an isolated manner and without monitoring one's affective state such as, anxiety. However, in conventional observation-based therapy, a therapist adjusts the intervention paradigm by monitoring one's anxiety level. But, often these individuals have an inherent inability to explicitly express their anxiety thereby inducing limitations on conventional techniques. Physiological signals being continuously available and not directly impacted by these communication difficulties can be alternatively used as markers of one's anxiety level. In our research we aim at designing a Virtual-reality bAsed Social-communication Task (VAST) system that can address the various aspects of social communication, e.g., social context, subtle social cues, emotional expression, etc., in a cumulative and structured way. In addition, we augment this with a capability to use one's physiological signals as markers of one's anxiety level. In our preliminary feasibility study we investigate the potential of VAST to cause variations in one's performance and anxiety level that can be mapped from one's physiological indices.

  16. Use of automated monitoring to assess behavioral toxicology in fish: Linking behavior and physiology

    USGS Publications Warehouse

    Brewer, S.K.; DeLonay, A.J.; Beauvais, S.L.; Little, E.E.; Jones, S.B.

    1999-01-01

    We measured locomotory behaviors (distance traveled, speed, tortuosity of path, and rate of change in direction) with computer-assisted analysis in 30 day posthatch rainbow trout (Oncorhynchus mykiss) exposed to pesticides. We also examined cholinesterase inhibition as a potential endpoint linking physiology and behavior. Sublethal exposure to chemicals often causes changes in swimming behavior, reflecting alterations in sensory and motor systems. Swimming behavior also integrates functions of the nervous system. Rarely are the connections between physiology and behavior made. Although behavior is often suggested as a sensitive, early indicator of toxicity, behavioral toxicology has not been used to its full potential because conventional methods of behavioral assessment have relied on manual techniques, which are often time-consuming and difficult to quantify. This has severely limited the application and utility of behavioral procedures. Swimming behavior is particularly amenable to computerized assessment and automated monitoring. Locomotory responses are sensitive to toxicants and can be easily measured. We briefly discuss the use of behavior in toxicology and automated techniques used in behavioral toxicology. We also describe the system we used to determine locomotory behaviors of fish, and present data demonstrating the system's effectiveness in measuring alterations in response to chemical challenges. Lastly, we correlate behavioral and physiological endpoints.

  17. A PMMA microfluidic dielectric sensor for blood coagulation monitoring at the point-of-care.

    PubMed

    Maji, Debnath; Suster, Michael A; Kucukal, Erdem; Gurkan, Umut A; Stavrou, Evi X; Mohseni, Pedram

    2016-08-01

    This paper describes the design and construct of a fully biocompatible, microfluidic, dielectric sensor targeted at monitoring human whole blood coagulation at the point-of-care (POC). The sensor assembly procedure involves using sputtered electrodes in a microfluidic channel with a physiologically relevant height of 50μm to create a three-dimensional (3D), parallel-plate, capacitive sensing area. The sensor is constructed with biocompatible materials of polymethyl methacrylate (PMMA) for the substrate and titanium nitride (TiN) for the sensing and floating electrodes. The real part of the complex relative dielectric permittivity of human whole blood is measured from 10kHz to 100MHz using an impedance analyzer and under static conditions. The temporal variation in dielectric permittivity at 1MHz for human whole blood undergoing coagulation shows a peak in permittivity at 5 minutes, which closely matches our previously established results. This sensor can pave the way for monitoring blood coagulation under physiologically relevant shear flow rates in the future.

  18. New method for monitoring nitric oxide in vivo using microdialysis sampling and chemiluminescence reaction

    NASA Astrophysics Data System (ADS)

    Yao, Dachun; Evmiridis, Nick P.; Zhou, Yikai; Xu, Shunqing; Zhou, Huarong

    2001-09-01

    A new method employing a combination of micro dialysis sampling and chemiluminescence reaction was developed to monitor nitric oxide (NO) in vivo. A special probe was designed with an interference-free membrane to achieve a very high selectivity for NO. High sensitivity was achieved by optimizing the working system and improving the NO sampling time. This system was used in vivo to monitor blood and brain tissue in rats and rabbits. We have established that this system is sensitive enough to detect variations in NO production in difference physiological state. The system can detect NO in the linear range of 5nM-1(mu) M, with a detection limit of 1nM, and real NO concentrations in our experimental animals were found to be in the range of 1-5 nM or even less. Finally, the effects of body temperature, NO donors, Viagra, NO activators, NO cofactors, NO interference were investigated carefully in different physiological situations.

  19. Wireless physiological monitoring and ocular tracking: 3D calibration in a fully-immersive virtual health care environment.

    PubMed

    Zhang, Lelin; Chi, Yu Mike; Edelstein, Eve; Schulze, Jurgen; Gramann, Klaus; Velasquez, Alvaro; Cauwenberghs, Gert; Macagno, Eduardo

    2010-01-01

    Wireless physiological/neurological monitoring in virtual reality (VR) offers a unique opportunity for unobtrusively quantifying human responses to precisely controlled and readily modulated VR representations of health care environments. Here we present such a wireless, light-weight head-mounted system for measuring electrooculogram (EOG) and electroencephalogram (EEG) activity in human subjects interacting with and navigating in the Calit2 StarCAVE, a five-sided immersive 3-D visualization VR environment. The system can be easily expanded to include other measurements, such as cardiac activity and galvanic skin responses. We demonstrate the capacity of the system to track focus of gaze in 3-D and report a novel calibration procedure for estimating eye movements from responses to the presentation of a set of dynamic visual cues in the StarCAVE. We discuss cyber and clinical applications that include a 3-D cursor for visual navigation in VR interactive environments, and the monitoring of neurological and ocular dysfunction in vision/attention disorders.

  20. A Survey on Wireless Body Area Networks for eHealthcare Systems in Residential Environments

    PubMed Central

    Ghamari, Mohammad; Janko, Balazs; Sherratt, R. Simon; Harwin, William; Piechockic, Robert; Soltanpur, Cinna

    2016-01-01

    Current progress in wearable and implanted health monitoring technologies has strong potential to alter the future of healthcare services by enabling ubiquitous monitoring of patients. A typical health monitoring system consists of a network of wearable or implanted sensors that constantly monitor physiological parameters. Collected data are relayed using existing wireless communication protocols to a base station for additional processing. This article provides researchers with information to compare the existing low-power communication technologies that can potentially support the rapid development and deployment of WBAN systems, and mainly focuses on remote monitoring of elderly or chronically ill patients in residential environments. PMID:27338377

  1. A Survey on Wireless Body Area Networks for eHealthcare Systems in Residential Environments.

    PubMed

    Ghamari, Mohammad; Janko, Balazs; Sherratt, R Simon; Harwin, William; Piechockic, Robert; Soltanpur, Cinna

    2016-06-07

    Current progress in wearable and implanted health monitoring technologies has strong potential to alter the future of healthcare services by enabling ubiquitous monitoring of patients. A typical health monitoring system consists of a network of wearable or implanted sensors that constantly monitor physiological parameters. Collected data are relayed using existing wireless communication protocols to a base station for additional processing. This article provides researchers with information to compare the existing low-power communication technologies that can potentially support the rapid development and deployment of WBAN systems, and mainly focuses on remote monitoring of elderly or chronically ill patients in residential environments.

  2. 40 CFR 60.2730 - What monitoring equipment must I install and what parameters must I monitor?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY... Units Model Rule-Monitoring § 60.2730 What monitoring equipment must I install and what parameters must...) of this section must be expressed in milligrams per dry standard cubic meter corrected to 7 percent...

  3. 40 CFR 60.2730 - What monitoring equipment must I install and what parameters must I monitor?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY... Units Model Rule-Monitoring § 60.2730 What monitoring equipment must I install and what parameters must...) of this section must be expressed in milligrams per dry standard cubic meter corrected to 7 percent...

  4. Why are we prolonging QT interval monitoring?

    PubMed

    Barrett, Trina

    2015-01-01

    At present, monitoring of the QT interval (QTI) is not a standard practice in the medical intensive care unit setting, where many drugs that prolong the QTI are administered. This literature review looked at the current research for evidence-based standards to support QTI monitoring of patients with risk factors for QTI prolongation, which can result in life-threatening arrhythmias such as torsade de pointes. The objective of this article is to establish the existence of evidence-based standards for monitoring of the QTI and to raise awareness in the nursing profession of the need for such monitoring among patients who are at high risk for prolonged QTI. To determine whether published standards for QTI monitoring exist, a search was conducted of the bibliographic databases CINAHL, EBSCOhost, Medline, PubMed, Google Scholar, and the Cochrane Library for the years 2013 and 2014. Also, a survey was conducted to determine whether practice standards for QTI monitoring are being implemented at 4 major hospitals in the Memphis area, including a level 1 trauma center. The database search established the existence of published guidelines that support the need for QTI monitoring. Results of the hospital survey indicated that direct care nurses were not aware of the need to identify high-risk patients, drugs with the potential to prolong QTI that were being administered to their patients, or evidence-based standards for QTI monitoring. Review of the research literature underscored the need for QTI monitoring among high-risk patients, that is, those with genetic conditions that predispose them to QTI prolongation, those with existing cardiac conditions being treated with antiarrhythmic medications, or those who are prescribed any new medication classified as high risk on the basis of clinical research. This need is especially crucial in intensive care unit settings, where many antiarrhythmic medications are administered.

  5. Randomized trial of the ForeseeHome monitoring device for early detection of neovascular age-related macular degeneration. The HOme Monitoring of the Eye (HOME) study design - HOME Study report number 1.

    PubMed

    Chew, Emily Y; Clemons, Traci E; Bressler, Susan B; Elman, Michael J; Danis, Ronald P; Domalpally, Amitha; Heier, Jeffrey S; Kim, Judy E; Garfinkel, Richard A

    2014-03-01

    To evaluate the effects of a home-monitoring device with tele-monitoring compared with standard care in detection of progression to choroidal neovascularization (CNV) associated with age-related macular degeneration (AMD), the leading cause of blindness in the US. Participants, aged 55 to 90 years, at high risk of developing CNV associated with AMD were recruited to the HOme Monitoring of Eye (HOME) Study, an unmasked, multi-center, randomized trial of the ForeseeHome (FH) device plus standard care vs. standard care alone. The FH device utilizes preferential hyperacuity perimetry and tele-monitoring to detect changes in vision function associated with development of CNV, potentially prior to symptom and visual acuity loss. After establishing baseline measurements, subsequent changes on follow-up are detected by the device, causing the monitoring center to alert the clinical center to recall participants for an exam. Standard care consists of instructions for self-monitoring visual changes with subsequent self-report to the clinical center. The primary objective of this study is to determine whether home monitoring plus standard care in comparison with standard care alone, results in earlier detection of incident CNV with better present visual acuity. The primary outcome is the decline in visual acuity at CNV diagnosis from baseline. Detection of CNV prior to substantial vision loss is critical as vision outcome following anti-angiogenic therapy is dependent on the visual acuity at initiation of treatment. HOME Study is the first large scale study to test the use of home tele-monitoring system in the management of AMD patients. Published by Elsevier Inc.

  6. Insulin Stimulates Translocation of Human GLUT4 to the Membrane in Fat Bodies of Transgenic Drosophila melanogaster

    PubMed Central

    Crivat, Georgeta; Lizunov, Vladimir A.; Li, Caroline R.; Stenkula, Karin G.; Zimmerberg, Joshua; Cushman, Samuel W.; Pick, Leslie

    2013-01-01

    The fruit fly Drosophila melanogaster is an excellent model system for studies of genes controlling development and disease. However, its applicability to physiological systems is less clear because of metabolic differences between insects and mammals. Insulin signaling has been studied in mammals because of relevance to diabetes and other diseases but there are many parallels between mammalian and insect pathways. For example, deletion of Drosophila Insulin-Like Peptides resulted in ‘diabetic’ flies with elevated circulating sugar levels. Whether this situation reflects failure of sugar uptake into peripheral tissues as seen in mammals is unclear and depends upon whether flies harbor the machinery to mount mammalian-like insulin-dependent sugar uptake responses. Here we asked whether Drosophila fat cells are competent to respond to insulin with mammalian-like regulated trafficking of sugar transporters. Transgenic Drosophila expressing human glucose transporter-4 (GLUT4), the sugar transporter expressed primarily in insulin-responsive tissues, were generated. After expression in fat bodies, GLUT4 intracellular trafficking and localization were monitored by confocal and total internal reflection fluorescence microscopy (TIRFM). We found that fat body cells responded to insulin with increased GLUT4 trafficking and translocation to the plasma membrane. While the amplitude of these responses was relatively weak in animals reared on a standard diet, it was greatly enhanced in animals reared on sugar-restricted diets, suggesting that flies fed standard diets are insulin resistant. Our findings demonstrate that flies are competent to mobilize translocation of sugar transporters to the cell surface in response to insulin. They suggest that Drosophila fat cells are primed for a response to insulin and that these pathways are down-regulated when animals are exposed to constant, high levels of sugar. Finally, these studies are the first to use TIRFM to monitor insulin-signaling pathways in Drosophila, demonstrating the utility of TIRFM of tagged sugar transporters to monitor signaling pathways in insects. PMID:24223128

  7. The "Ice-Mile": Case Study of 2 Swimmers' Selected Physiological Responses and Performance.

    PubMed

    Kenny, John; Cullen, SarahJane; Warrington, Giles D

    2017-05-01

    "Ice-mile" swimming presents significant physiological challenges and potential safety issues, but few data are available. This study examined deep body temperature (BT), respiratory rate (RR), and swim performance in 2 swimmers completing an ice-mile swim of 1 mile (1600 m) in water less than 5°C. Two male cold-water-habituated swimmers completed a 1-mile lake swim in 3.9°C water. For comparative purposes, they completed an indoor 1-mile swim in 28.1°C water. The Equivital physiological monitoring system was used to record BT and RR before, during, and after each swim. Total time to complete the swims and 400-m splits were recorded. One swimmer became hypothermic after 27 min while swimming, reaching BT of 33.7°C at swim's end. On exiting the water the swimmers experienced large BT after-drops of -3.6°C and -2.4°C, reaching low points of 33.2°C and 31.3°C 38 and 23 min postswim, respectively. Respiratory rate and swim pace decreased over the course of the ice-mile swim for both swimmers. Swim pace for 1 swimmer declined sharply in the final 400-m lap of the ice mile when he was hypothermic. Both swimmers remained hypothermic 60 min postswim (34.2°C and 33.4°C). Ice-mile swimmers may become hypothermic while swimming, and the postswim BT after drop may expose them to dangerous levels of hypothermia. Pace and RR should be monitored as proxies for a swimmer's physiological state. Postswim recovery should also be monitored for hypothermia for at least 1 h.

  8. Automated detection of physiologic deterioration in hospitalized patients.

    PubMed

    Evans, R Scott; Kuttler, Kathryn G; Simpson, Kathy J; Howe, Stephen; Crossno, Peter F; Johnson, Kyle V; Schreiner, Misty N; Lloyd, James F; Tettelbach, William H; Keddington, Roger K; Tanner, Alden; Wilde, Chelbi; Clemmer, Terry P

    2015-03-01

    Develop and evaluate an automated case detection and response triggering system to monitor patients every 5 min and identify early signs of physiologic deterioration. A 2-year prospective, observational study at a large level 1 trauma center. All patients admitted to a 33-bed medical and oncology floor (A) and a 33-bed non-intensive care unit (ICU) surgical trauma floor (B) were monitored. During the intervention year, pager alerts of early physiologic deterioration were automatically sent to charge nurses along with access to a graphical point-of-care web page to facilitate patient evaluation. Nurses reported the positive predictive value of alerts was 91-100% depending on erroneous data presence. Unit A patients were significantly older and had significantly more comorbidities than unit B patients. During the intervention year, unit A patients had a significant increase in length of stay, more transfers to ICU (p = 0.23), and significantly more medical emergency team (MET) calls (p = 0.0008), and significantly fewer died (p = 0.044) compared to the pre-intervention year. No significant differences were found on unit B. We monitored patients every 5 min and provided automated pages of early physiologic deterioration. This before-after study found a significant increase in MET calls and a significant decrease in mortality only in the unit with older patients with multiple comorbidities, and thus further study is warranted to detect potential confounding. Moreover, nurses reported the graphical alerts provided information needed to quickly evaluate patients, and they felt more confident about their assessment and more comfortable requesting help. © The Author 2014. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  9. Interpersonal Autonomic Physiology: A Systematic Review of the Literature.

    PubMed

    Palumbo, Richard V; Marraccini, Marisa E; Weyandt, Lisa L; Wilder-Smith, Oliver; McGee, Heather A; Liu, Siwei; Goodwin, Matthew S

    2017-05-01

    Interpersonal autonomic physiology is defined as the relationship between people's physiological dynamics, as indexed by continuous measures of the autonomic nervous system. Findings from this field of study indicate that physiological activity between two or more people can become associated or interdependent, often referred to as physiological synchrony. Physiological synchrony has been found in both new and established relationships across a range of contexts, and it correlates with a number of psychosocial constructs. Given these findings, interpersonal physiological interactions are theorized to be ubiquitous social processes that co-occur with observable behavior. However, this scientific literature is fragmented, making it difficult to evaluate consistency across reports. In an effort to facilitate more standardized scholarly approaches, this systematic review provides a description of existing work in the area and highlights theoretical, methodological, and statistical issues to be addressed in future interpersonal autonomic physiology research.

  10. [A study of biomechanical method for urine test based on color difference estimation].

    PubMed

    Wang, Chunhong; Zhou, Yue; Zhao, Hongxia; Zhou, Fengkun

    2008-02-01

    The biochemical analysis of urine is an important inspection and diagnosis method in hospitals. The conventional method of urine analysis covers mainly colorimetric visual appraisement and automation detection, in which the colorimetric visual appraisement technique has been superseded basically, and the automation detection method is adopted in hospital; moreover, the price of urine biochemical analyzer on market is around twenty thousand RMB yuan (Y), which is hard to enter into ordinary families. It is known that computer vision system is not subject to the physiological and psychological influence of person, its appraisement standard is objective and steady. Therefore, according to the color theory, we have established a computer vision system, which can carry through collection, management, display, and appraisement of color difference between the color of standard threshold value and the color of urine test paper after reaction with urine liquid, and then the level of an illness can be judged accurately. In this paper, we introduce the Urine Test Biochemical Analysis method, which is new and can be popularized in families. Experimental result shows that this test method is easy-to-use and cost-effective. It can realize the monitoring of a whole course and can find extensive applications.

  11. Behavioural and physiological effects of finely balanced decision-making in chickens.

    PubMed

    Davies, Anna C; Nicol, Christine J; Persson, Mia E; Radford, Andrew N

    2014-01-01

    In humans, more difficult decisions result in behavioural and physiological changes suggestive of increased arousal, but little is known about the effect of decision difficulty in other species. A difficult decision can have a number of characteristics; we aimed to monitor how finely balanced decisions, compared to unbalanced ones, affected the behaviour and physiology of chickens. An unbalanced decision was one in which the two options were of unequal net value (1 (Q1) vs. 6 (Q6) pieces of sweetcorn with no cost associated with either option); a finely balanced decision was one in which the options were of equal net value (i.e. hens were "indifferent" to both options). To identify hens' indifference, a titration procedure was used in which a cost (electromagnetic weight on an access door) was applied to the Q6 option, to find the individual point at which hens chose this option approximately equally to Q1 via a non-weighted door. We then compared behavioural and physiological indicators of arousal (head movements, latency to choose, heart-rate variability and surface body temperature) when chickens made decisions that were unbalanced or finely balanced. Significant physiological (heart-rate variability) and behavioural (latency to pen) differences were found between the finely balanced and balanced conditions, but these were likely to be artefacts of the greater time and effort required to push through the weighted doors. No other behavioural and physiological measures were significantly different between the decision categories. We suggest that more information is needed on when best to monitor likely changes in arousal during decision-making and that future studies should consider decisions defined as difficult in other ways.

  12. Near-infrared diffuse optical monitoring of cerebral blood flow and oxygenation for the prediction of vasovagal syncope

    NASA Astrophysics Data System (ADS)

    Cheng, Ran; Shang, Yu; Wang, Siqi; Evans, Joyce M.; Rayapati, Abner; Randall, David C.; Yu, Guoqiang

    2014-01-01

    Significant drops in arterial blood pressure and cerebral hemodynamics have been previously observed during vasovagal syncope (VVS). Continuous and simultaneous monitoring of these physiological variables during VVS is rare, but critical for determining which variable is the most sensitive parameter to predict VVS. The present study used a novel custom-designed diffuse correlation spectroscopy flow-oximeter and a finger plethysmograph to simultaneously monitor relative changes of cerebral blood flow (rCBF), cerebral oxygenation (i.e., oxygenated/deoxygenated/total hemoglobin concentration: r[HbO2]/r[Hb]/rTHC), and mean arterial pressure (rMAP) during 70 deg head-up tilt (HUT) in 14 healthy adults. Six subjects developed presyncope during HUT. Two-stage physiological responses during HUT were observed in the presyncopal group: slow and small changes in measured variables (i.e., Stage I), followed by rapid and dramatic decreases in rMAP, rCBF, r[HbO2], and rTHC (i.e., Stage II). Compared to other physiological variables, rCBF reached its breakpoint between the two stages earliest and had the largest decrease (76±8%) during presyncope. Our results suggest that rCBF has the best sensitivity for the assessment of VVS. Most importantly, a threshold of ˜50% rCBF decline completely separated the subjects from those without presyncope, suggesting its potential for predicting VVS.

  13. A pervasive health monitoring service system based on ubiquitous network technology.

    PubMed

    Lin, Chung-Chih; Lee, Ren-Guey; Hsiao, Chun-Chieh

    2008-07-01

    The phenomenon of aging society has derived problems such as shortage of medical resources and reduction of quality in healthcare services. This paper presents a system infrastructure for pervasive and long-term healthcare applications, i.e. a ubiquitous network composed of wireless local area network (WLAN) and cable television (CATV) network serving as a platform for monitoring physiological signals. Users can record vital signs including heart rate, blood pressure, and body temperature anytime either at home or at frequently visited public places in order to create a personal health file. The whole system was formally implemented in December 2004. Analysis of 2000 questionnaires indicates that 85% of users were satisfied with the provided community-wide healthcare services. Among the services provided by our system, health consultation services offered by family doctors was rated the most important service by 17.9% of respondents, and was followed by control of one's own health condition (16.4% of respondents). Convenience of data access was rated most important by roughly 14.3% of respondents. We proposed and implemented a long-term healthcare system integrating WLAN and CATV networks in the form of a ubiquitous network providing a service platform for physiological monitoring. This system can classify the health levels of the resident according to the variation tendency of his or her physiological signal for important reference of health management.

  14. ST-segment monitoring: putting standards into practice.

    PubMed

    Flanders, Sonya A

    2007-01-01

    ST-segment monitoring is one key reason that continuous electrocardiographic monitoring is performed in hospitals, and can help with early detection of myocardial ischemia for at-risk patients. Although ST-segment monitoring research, guidelines, and expert consensus statements have been published, ST-segment monitoring has not been implemented in all appropriate clinical areas. The purpose of this article is to present relevant research, review the latest practice standards, and discuss issues important to nurses wishing to implement ST-segment monitoring.

  15. Diffuse Optical Monitoring of the Neoadjuvant Breast Cancer Therapy

    PubMed Central

    Choe, Regine; Durduran, Turgut

    2012-01-01

    Recent advances in the use of diffuse optical techniques for monitoring the hemodynamic, metabolic and physiological signatures of the neoadjuvant breast cancer therapy effectiveness is critically reviewed. An extensive discussion of the state-of-theart diffuse optical mammography is presented alongside a discussion of the current approaches to breast cancer therapies. Overall, the diffuse optics field is growing rapidly with a great deal of promise to fill an important niche in the current approaches to monitor, predict and personalize neoadjuvant breast cancer therapies. PMID:23243386

  16. 40 CFR 63.3350 - If I use a control device to comply with the emission standards, what monitoring must I do?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... must be certified by the manufacturer to be accurate to within ±2.0 percent by mass. (e) Continuous... Pollutants: Paper and Other Web Coating General Requirements for Compliance with the Emission Standards and... standards, what monitoring must I do? (a) A summary of monitoring you must do follows: If you operate a web...

  17. 40 CFR 63.3350 - If I use a control device to comply with the emission standards, what monitoring must I do?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... must be certified by the manufacturer to be accurate to within ±2.0 percent by mass. (e) Continuous... Pollutants: Paper and Other Web Coating General Requirements for Compliance with the Emission Standards and... standards, what monitoring must I do? (a) A summary of monitoring you must do follows: If you operate a web...

  18. A Brief Review of Non-invasive Monitoring of Respiratory Condition for Extubated Patients with or at Risk for Obstructive Sleep Apnea after Surgery

    PubMed Central

    Zhang, Xuezheng; Kassem, Mahmoud Attia Mohamed; Zhou, Ying; Shabsigh, Muhammad; Wang, Quanguang; Xu, Xuzhong

    2017-01-01

    Obstructive sleep apnea (OSA) is one of the important risk factors contributing to postoperative airway complications. OSA alters the respiratory physiology and increases the sensitivity of muscle tone of the upper airway after surgery to residual anesthetic medication. In addition, the prevalence of OSA was reported to be much higher among surgical patients than the general population. Therefore, appropriate monitoring to detect early respiratory impairment in postoperative extubated patients with possible OSA is challenging. Based on the comprehensive clinical observation, several equipment have been used for monitoring the respiratory conditions of OSA patients after surgery, including the continuous pulse oximetry, capnography, photoplethysmography (PPG), and respiratory volume monitor (RVM). To date, there has been no consensus on the most suitable device as a recommended standard of care. In this review, we describe the advantages and disadvantages of some possible monitoring strategies under certain clinical conditions. According to the literature, the continuous pulse oximetry, with its high sensitivity, is still the most widely used device. It is also cost-effective and convenient to use but has low specificity and does not reflect ventilation. Capnography is the most widely used device for detection of hypoventilation, but it may not provide reliable data for extubated patients. Even normal capnography cannot exclude the existence of hypoxia. PPG shows the state of both ventilation and oxygenation, but its sensitivity needs further improvement. RVM provides real-time detection of hypoventilation, quantitative precise demonstration of respiratory rate, tidal volume, and MV for extubated patients, but no reflection of oxygenation. Altogether, the sole use of any of these devices is not ideal for monitoring of extubated patients with or at risk for OSA after surgery. However, we expect that the combined use of continuous pulse oximetry and RVM may be promising for these patients due to their complementary function, which need further study. PMID:28337439

  19. Physiological responses induced by pleasant stimuli.

    PubMed

    Watanuki, Shigeki; Kim, Yeon-Kyu

    2005-01-01

    The specific physiological responses induced by pleasant stimuli were investigated in this study. Various physiological responses of the brain (encephaloelectrogram; EEG), autonomic nervous system (ANS), immune system and endocrine system were monitored when pleasant stimuli such as odors, emotional pictures and rakugo, a typical Japanese comical story-telling, were presented to subjects. The results revealed that (i) EEG activities of the left frontal brain region were enhanced by a pleasant odor; (ii) emotional pictures related to primitive element such as nudes and erotic couples elevated vasomotor sympathetic nervous activity; and (iii) an increase in secretory immunoglobulin A (s-IgA) and a decrease in salivary cortisol (s-cortisol) were induced by rakugo-derived linguistic pleasant emotion. Pleasant emotion is complicated state. However, by considering the evolutionary history of human being, it is possible to assess and evaluate pleasant emotion from certain physiological responses by appropriately summating various physiological parameters.

  20. Cognitive Technologies for Teams 711HPW/RHCPT

    DTIC Science & Technology

    2010-09-01

    robust physiological indices of team workload, with a particular interest in minimally invasive measures such as EEG, EOG , ECG eye movement data and...cerebral hemodynamics. Current research directions for the CTT program will be discussed. 15. SUBJECT TERMS 16. SECURITY CLASSIFICATION OF: 17...collections of individuals TRACE Monitor 12 Cerebral Hemodynamics • Transcranial Doppler Sonography (TCD) – Utilizes ultrasound signals to monitor

  1. 40 CFR 271.12 - Requirements for hazardous waste management facilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... and 266. These standards shall include: (a) Technical standards for tanks, containers, waste piles...-closure monitoring and maintenance; (e) Groundwater monitoring; (f) Security to prevent unauthorized access to the facility; (g) Facility personnel training; (h) Inspections, monitoring, recordkeeping, and...

  2. 40 CFR 271.12 - Requirements for hazardous waste management facilities.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... and 266. These standards shall include: (a) Technical standards for tanks, containers, waste piles...-closure monitoring and maintenance; (e) Groundwater monitoring; (f) Security to prevent unauthorized access to the facility; (g) Facility personnel training; (h) Inspections, monitoring, recordkeeping, and...

  3. 40 CFR 271.12 - Requirements for hazardous waste management facilities.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... and 266. These standards shall include: (a) Technical standards for tanks, containers, waste piles...-closure monitoring and maintenance; (e) Groundwater monitoring; (f) Security to prevent unauthorized access to the facility; (g) Facility personnel training; (h) Inspections, monitoring, recordkeeping, and...

  4. 40 CFR 271.12 - Requirements for hazardous waste management facilities.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... and 266. These standards shall include: (a) Technical standards for tanks, containers, waste piles...-closure monitoring and maintenance; (e) Groundwater monitoring; (f) Security to prevent unauthorized access to the facility; (g) Facility personnel training; (h) Inspections, monitoring, recordkeeping, and...

  5. 40 CFR 271.12 - Requirements for hazardous waste management facilities.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... and 266. These standards shall include: (a) Technical standards for tanks, containers, waste piles...-closure monitoring and maintenance; (e) Groundwater monitoring; (f) Security to prevent unauthorized access to the facility; (g) Facility personnel training; (h) Inspections, monitoring, recordkeeping, and...

  6. Dynamic quantitative photothermal monitoring of cell death of individual human red blood cells upon glucose depletion

    NASA Astrophysics Data System (ADS)

    Vasudevan, Srivathsan; Chen, George Chung Kit; Andika, Marta; Agarwal, Shuchi; Chen, Peng; Olivo, Malini

    2010-09-01

    Red blood cells (RBCs) have been found to undergo ``programmed cell death,'' or eryptosis, and understanding this process can provide more information about apoptosis of nucleated cells. Photothermal (PT) response, a label-free photothermal noninvasive technique, is proposed as a tool to monitor the cell death process of living human RBCs upon glucose depletion. Since the physiological status of the dying cells is highly sensitive to photothermal parameters (e.g., thermal diffusivity, absorption, etc.), we applied linear PT response to continuously monitor the death mechanism of RBC when depleted of glucose. The kinetics of the assay where the cell's PT response transforms from linear to nonlinear regime is reported. In addition, quantitative monitoring was performed by extracting the relevant photothermal parameters from the PT response. Twofold increases in thermal diffusivity and size reduction were found in the linear PT response during cell death. Our results reveal that photothermal parameters change earlier than phosphatidylserine externalization (used for fluorescent studies), allowing us to detect the initial stage of eryptosis in a quantitative manner. Hence, the proposed tool, in addition to detection of eryptosis earlier than fluorescence, could also reveal physiological status of the cells through quantitative photothermal parameter extraction.

  7. Monitoring temporal microstructural variations of skeletal muscle tissues by multispectral Mueller matrix polarimetry

    NASA Astrophysics Data System (ADS)

    Dong, Yang; He, Honghui; He, Chao; Ma, Hui

    2017-02-01

    Mueller matrix polarimetry is a powerful tool for detecting microscopic structures, therefore can be used to monitor physiological changes of tissue samples. Meanwhile, spectral features of scattered light can also provide abundant microstructural information of tissues. In this paper, we take the 2D multispectral backscattering Mueller matrix images of bovine skeletal muscle tissues, and analyze their temporal variation behavior using multispectral Mueller matrix parameters. The 2D images of the Mueller matrix elements are reduced to the multispectral frequency distribution histograms (mFDHs) to reveal the dominant structural features of the muscle samples more clearly. For quantitative analysis, the multispectral Mueller matrix transformation (MMT) parameters are calculated to characterize the microstructural variations during the rigor mortis and proteolysis processes of the skeletal muscle tissue samples. The experimental results indicate that the multispectral MMT parameters can be used to judge different physiological stages for bovine skeletal muscle tissues in 24 hours, and combining with the multispectral technique, the Mueller matrix polarimetry and FDH analysis can monitor the microstructural variation features of skeletal muscle samples. The techniques may be used for quick assessment and quantitative monitoring of meat qualities in food industry.

  8. Data Mining for Wearable Sensors in Health Monitoring Systems: A Review of Recent Trends and Challenges

    PubMed Central

    Banaee, Hadi; Ahmed, Mobyen Uddin; Loutfi, Amy

    2013-01-01

    The past few years have witnessed an increase in the development of wearable sensors for health monitoring systems. This increase has been due to several factors such as development in sensor technology as well as directed efforts on political and stakeholder levels to promote projects which address the need for providing new methods for care given increasing challenges with an aging population. An important aspect of study in such system is how the data is treated and processed. This paper provides a recent review of the latest methods and algorithms used to analyze data from wearable sensors used for physiological monitoring of vital signs in healthcare services. In particular, the paper outlines the more common data mining tasks that have been applied such as anomaly detection, prediction and decision making when considering in particular continuous time series measurements. Moreover, the paper further details the suitability of particular data mining and machine learning methods used to process the physiological data and provides an overview of the properties of the data sets used in experimental validation. Finally, based on this literature review, a number of key challenges have been outlined for data mining methods in health monitoring systems. PMID:24351646

  9. Use of continuous electronic fetal monitoring in a preterm fetus: clinical dilemmas and recommendations for practice.

    PubMed

    Afors, Karolina; Chandraharan, Edwin

    2011-01-01

    The aim of intrapartum continuous electronic fetal monitoring using a cardiotocograph (CTG) is to identify a fetus exposed to intrapartum hypoxic insults so that timely and appropriate action could be instituted to improve perinatal outcome. Features observed on a CTG trace reflect the functioning of somatic and autonomic nervous systems and the fetal response to hypoxic or mechanical insults during labour. Although, National Guidelines on electronic fetal monitoring exist for term fetuses, there is paucity of recommendations based on scientific evidence for monitoring preterm fetuses during labour. Lack of evidence-based recommendations may pose a clinical dilemma as preterm births account for nearly 8% (1 in 13) live births in England and Wales. 93% of these preterm births occur after 28 weeks, 6% between 22-27 weeks, and 1% before 22 weeks. Physiological control of fetal heart rate and the resultant features observed on the CTG trace differs in the preterm fetus as compared to a fetus at term making interpretation difficult. This review describes the features of normal fetal heart rate patterns at different gestations and the physiological responses of a preterm fetus compared to a fetus at term. We have proposed an algorithm "ACUTE" to aid management.

  10. Data mining for wearable sensors in health monitoring systems: a review of recent trends and challenges.

    PubMed

    Banaee, Hadi; Ahmed, Mobyen Uddin; Loutfi, Amy

    2013-12-17

    The past few years have witnessed an increase in the development of wearable sensors for health monitoring systems. This increase has been due to several factors such as development in sensor technology as well as directed efforts on political and stakeholder levels to promote projects which address the need for providing new methods for care given increasing challenges with an aging population. An important aspect of study in such system is how the data is treated and processed. This paper provides a recent review of the latest methods and algorithms used to analyze data from wearable sensors used for physiological monitoring of vital signs in healthcare services. In particular, the paper outlines the more common data mining tasks that have been applied such as anomaly detection, prediction and decision making when considering in particular continuous time series measurements. Moreover, the paper further details the suitability of particular data mining and machine learning methods used to process the physiological data and provides an overview of the properties of the data sets used in experimental validation. Finally, based on this literature review, a number of key challenges have been outlined for data mining methods in health monitoring systems.

  11. Cost-effectiveness of workplace wellness to prevent cardiovascular events among U.S. firefighters.

    PubMed

    Patterson, P Daniel; Smith, Kenneth J; Hostler, David

    2016-11-21

    The leading cause of death among firefighters in the United States (U.S.) is cardiovascular events (CVEs) such as sudden cardiac arrest and myocardial infarction. This study compared the cost-effectiveness of three strategies to prevent CVEs among firefighters. We used a cost-effectiveness analysis model with published observational and clinical data, and cost quotes for physiologic monitoring devices to determine the cost-effectiveness of three CVE prevention strategies. We adopted the fire department administrator perspective and varied parameter estimates in one-way and two-way sensitivity analyses. A wellness-fitness program prevented 10% of CVEs, for an event rate of 0.9% at $1440 over 10-years, or an incremental cost-effectiveness ratio of $1.44 million per CVE prevented compared to no program. In one-way sensitivity analyses, monitoring was favored if costs were < $116/year. In two-way sensitivity analyses, monitoring was not favored if cost was ≥ $399/year. A wellness-fitness program was not favored if its preventive relative risk was >0.928. Wellness-fitness programs may be a cost-effective solution to preventing CVE among firefighters compared to real-time physiologic monitoring or doing nothing.

  12. A conceptual framework for the emerging discipline of conservation physiology

    PubMed Central

    Coristine, Laura E.; Robillard, Cassandra M.; Kerr, Jeremy T.; O'Connor, Constance M.; Lapointe, Dominique; Cooke, Steven J.

    2014-01-01

    Current rates of biodiversity decline are unprecedented and largely attributed to anthropogenic influences. Given the scope and magnitude of conservation issues, policy and management interventions must maximize efficiency and efficacy. The relatively new field of conservation physiology reveals the physiological mechanisms associated with population declines, animal–environment relationships and population or species tolerance thresholds, particularly where these relate to anthropogenic factors that necessitate conservation action. We propose a framework that demonstrates an integrative approach between physiology, conservation and policy, where each can inform the design, conduct and implementation of the other. Each junction of the conservation physiology process has the capacity to foster dialogue that contributes to effective implementation, monitoring, assessment and evaluation. This approach enables effective evaluation and implementation of evidence-based conservation policy and management decisions through a process of ongoing refinement, but may require that scientists (from the disciplines of both physiology and conservation) and policy-makers bridge interdisciplinary knowledge gaps. Here, we outline a conceptual framework that can guide and lead developments in conservation physiology, as well as promote innovative research that fosters conservation-motivated policy. PMID:27293654

  13. Performance in physiology evaluation: possible improvement by active learning strategies.

    PubMed

    Montrezor, Luís H

    2016-12-01

    The evaluation process is complex and extremely important in the teaching/learning process. Evaluations are constantly employed in the classroom to assist students in the learning process and to help teachers improve the teaching process. The use of active methodologies encourages students to participate in the learning process, encourages interaction with their peers, and stimulates thinking about physiological mechanisms. This study examined the performance of medical students on physiology over four semesters with and without active engagement methodologies. Four activities were used: a puzzle, a board game, a debate, and a video. The results show that engaging in activities with active methodologies before a physiology cognitive monitoring test significantly improved student performance compared with not performing the activities. We integrate the use of these methodologies with classic lectures, and this integration appears to improve the teaching/learning process in the discipline of physiology and improves the integration of physiology with cardiology and neurology. In addition, students enjoy the activities and perform better on their evaluations when they use them. Copyright © 2016 The American Physiological Society.

  14. Intraoperative Monitoring: Recent Advances in Motor Evoked Potentials.

    PubMed

    Koht, Antoun; Sloan, Tod B

    2016-09-01

    Advances in electrophysiological monitoring have improved the ability of surgeons to make decisions and minimize the risks of complications during surgery and interventional procedures when the central nervous system (CNS) is at risk. Individual techniques have become important for identifying or mapping the location and pathway of critical neural structures. These techniques are also used to monitor the progress of procedures to augment surgical and physiologic management so as to reduce the risk of CNS injury. Advances in motor evoked potentials have facilitated mapping and monitoring of the motor tracts in newer, more complex procedures. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Classifying obstructive sleep apnea using smartphones.

    PubMed

    Al-Mardini, Mamoun; Aloul, Fadi; Sagahyroon, Assim; Al-Husseini, Luai

    2014-12-01

    Obstructive sleep apnea (OSA) is a serious sleep disorder which is characterized by frequent obstruction of the upper airway, often resulting in oxygen desaturation. The serious negative impact of OSA on human health makes monitoring and diagnosing it a necessity. Currently, polysomnography is considered the gold standard for diagnosing OSA, which requires an expensive attended overnight stay at a hospital with considerable wiring between the human body and the system. In this paper, we implement a reliable, comfortable, inexpensive, and easily available portable device that allows users to apply the OSA test at home without the need for attended overnight tests. The design takes advantage of a smatrphone's built-in sensors, pervasiveness, computational capabilities, and user-friendly interface to screen OSA. We use three main sensors to extract physiological signals from patients which are (1) an oximeter to measure the oxygen level, (2) a microphone to record the respiratory effort, and (3) an accelerometer to detect the body's movement. Finally, we examine our system's ability to screen the disease as compared to the gold standard by testing it on 15 samples. The results showed that 100% of patients were correctly identified as having the disease, and 85.7% of patients were correctly identified as not having the disease. These preliminary results demonstrate the effectiveness of the developed system when compared to the gold standard and emphasize the important role of smartphones in healthcare. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. Radio telemetry devices to monitor breathing in non-sedated animals.

    PubMed

    Samson, Nathalie; Dumont, Sylvain; Specq, Marie-Laure; Praud, Jean-Paul

    2011-12-15

    Radio telemetry equipment has significantly improved over the last 10-15 years and is increasingly being used in research for monitoring a variety of physiological parameters in non-sedated animals. The aim of this review is to provide an update on the current state of development of radio telemetry for recording respiration. Our literature review found only rare reports of respiratory studies via radio telemetry. Much of this article will hence report our experience with our custom-built radio telemetry devices designed for recording respiratory signals, together with numerous other physiological signals in lambs. Our current radio telemetry system allows to record 24 simultaneous signals 24h/day for several days. To our knowledge, this is the highest number of physiological signals, which can be recorded wirelessly. Our devices have been invaluable for studying respiration in our ovine models of preterm birth, reflux laryngitis, postnatal exposure to cigarette smoke, respiratory syncytial virus infection and nasal ventilation, all of which are relevant to neonatal respiratory problems. Copyright © 2011 Elsevier B.V. All rights reserved.

  17. The promise of wearable sensors and ecological momentary assessment measures for dynamical systems modeling in adolescents: a feasibility and acceptability study.

    PubMed

    Brannon, Erin E; Cushing, Christopher C; Crick, Christopher J; Mitchell, Tarrah B

    2016-12-01

    Intervention development can be accelerated by using wearable sensors and ecological momentary assessment (EMA) to study how behaviors change within a person. The purpose of this study was to determine the feasibility and acceptability of a novel, intensive EMA method for assessing physiology, behavior, and psychosocial variables utilizing two objective sensors and a mobile application (app). Adolescents (n = 20) enrolled in a 20-day EMA protocol. Participants wore a physiological monitor and an accelerometer that measured sleep and physical activity and completed four surveys per day on an app. Participants provided approximately 81 % of the expected survey data. Participants were compliant to the wrist-worn accelerometer (75.3 %), which is a feasible measurement of physical activity/sleep (74.1 % complete data). The data capture (47.8 %) and compliance (70.28 %) with the physiological monitor were lower than other study variables. The findings support the use of an intensive assessment protocol to study real-time relationships between biopsychosocial variables and health behaviors.

  18. Physiological monitoring and control in hemodialysis: state of the art and outlook.

    PubMed

    Kraemer, Matthias

    2006-09-01

    Medical devices for monitoring and feedback control of physiological parameters of the dialysis patient were introduced in the early 1990s. They have a wide range of applications, aiming at increasing the safety and ensuring the efficiency of the treatment, and at an improved restoration of physiological conditions, leading to an overall reduction in morbidity and mortality. Such devices include sensors for the measurement of temperature, optical parameters and sound speed in blood, and electrical characteristics of the human body, and other parameters. Essential for the development of these devices is a detailed understanding of the pathophysiological background of a therapeutical problem. There is still a large potential to introduce new devices for further therapy improvement and automation. Also, the size of the hemodialysis market appears attractive; however, a new product has to meet several specific requirements in order to also become commercially successful. This review describes the therapeutic and technical principles of several available devices, reports on concepts for possible future devices, and presents a short overview on the market environment.

  19. The use of nonhuman primates in space

    NASA Technical Reports Server (NTRS)

    Simmonds, R. C. (Editor); Bourne, G. H. (Editor)

    1977-01-01

    Space related biomedical research involving nonhuman primates is reviewed. The scientific assets of various species and the instruments used for monitoring physiological processes during long duration experimentations are described.

  20. Perfusionist

    MedlinePlus

    ... Perfusionists conduct extracorporeal circulation and ensure the safe management of physiologic functions by monitoring the necessary variables. Perfusion (extracorporeal circulation) procedures involve specialized instrumentation and/or advanced life-support techniques and may include a variety ...

  1. Antenatal Testing – A Reevaluation

    PubMed Central

    Signore, Caroline; Freeman, Roger K.; Spong, Catherine Y.

    2009-01-01

    In August 2007, the Eunice Kennedy Shriver National Institute of Child Health and Human Development, the National Institutes of Health Office of Rare Diseases, the American College of Obstetricians and Gynecologists, and the American Academy of Pediatrics cosponsored a 2-day workshop to reassess the body of evidence supporting antepartum assessment of fetal well-being, identify key gaps in the evidence, and formulate recommendations for further research. Participants included experts in obstetrics and fetal physiology, and representatives from relevant stakeholder groups and organizations. This article is a summary of the discussions at the workshop, including synopses of oral presentations on the epidemiology of stillbirth and fetal neurological injury, fetal physiology, techniques for antenatal monitoring, and maternal and fetal indications for monitoring. Finally, a synthesis of recommendations for further research compiled from three breakout workgroups is presented. PMID:19300336

  2. Fetal Heart Rate Monitoring During Surgical Correction of Spontaneous Pneumothorax During Pregnancy: Lessons in In Utero Resuscitation.

    PubMed

    Wilson, Bailey; Burt, Bryan; Baker, Byron; Clark, Steven L; Belfort, Michael; Gandhi, Manisha

    2016-01-01

    Spontaneous pneumothorax during pregnancy has potentially serious implications for the mother and fetus. When surgical correction is required, complex maternal physiologic alterations may significantly affect fetal well-being. A woman underwent thoracoscopic lung resection and pleurodesis at 29 weeks of gestation. At various points during the procedure, maternal hemodynamic and respiratory consequences of anesthetic and surgical management resulted in severe fetal heart rate (FHR) decelerations and bradycardia. In each instance, physiologic manipulations based on an understanding of the likely cause of fetal hypoxia allowed correction of the FHR abnormalities without delivery. Nonsurgical perinatal intervention based on FHR monitoring and analysis of the likely pathophysiologic abnormalities underlying fetal decelerations may allow the gravid woman to undergo complex procedures and continue the pregnancy.

  3. Earpiece with sensors to measure/monitor multiple physiological variables

    NASA Technical Reports Server (NTRS)

    Cooper, Tommy G. (Inventor); Schulze, Arthur E. (Inventor)

    2003-01-01

    An apparatus and method for positioning sensors relative to one another and anatomic features in a non-invasive device for measuring and monitoring multiple physiological variables from a single site uses an earpiece incorporating a shielded pulse oximetry sensor (POS) having a miniaturized set of LEDs and photosensors configured for pulse oximetry measurements in the reflectance mode and located in the earpiece so as to position the POS against a rear wall of an ear canal. The earpiece also includes a thermopile of no larger than 7 mm. in diameter located on the earpiece to so as to position the thermopile past a second turn of an external auditory meatus so as to view the tympanic membrane. The thermopile includes a reference temperature sensor attached to its base for ambient temperature compensation.

  4. Multi-complexity ensemble measures for gait time series analysis: application to diagnostics, monitoring and biometrics.

    PubMed

    Gavrishchaka, Valeriy; Senyukova, Olga; Davis, Kristina

    2015-01-01

    Previously, we have proposed to use complementary complexity measures discovered by boosting-like ensemble learning for the enhancement of quantitative indicators dealing with necessarily short physiological time series. We have confirmed robustness of such multi-complexity measures for heart rate variability analysis with the emphasis on detection of emerging and intermittent cardiac abnormalities. Recently, we presented preliminary results suggesting that such ensemble-based approach could be also effective in discovering universal meta-indicators for early detection and convenient monitoring of neurological abnormalities using gait time series. Here, we argue and demonstrate that these multi-complexity ensemble measures for gait time series analysis could have significantly wider application scope ranging from diagnostics and early detection of physiological regime change to gait-based biometrics applications.

  5. Biomarkers for pediatric sepsis and septic shock

    PubMed Central

    Standage, Stephen W; Wong, Hector R

    2011-01-01

    Sepsis is a clinical syndrome defined by physiologic changes indicative of systemic inflammation, which are likely attributable to documented or suspected infection. Septic shock is the progression of those physiologic changes to the extent that delivery of oxygen and metabolic substrate to tissues is compromised. Biomarkers have the potential to diagnose, monitor, stratify and predict outcome in these syndromes. C-reactive protein is elevated in inflammatory and infectious conditions and has long been used as a biomarker indicating infection. Procalcitonin has more recently been shown to better distinguish infection from inflammation. Newer candidate biomarkers for infection include IL-18 and CD64. Lactate facilitates the diagnosis of septic shock and the monitoring of its progression. Multiple stratification biomarkers based on genome-wide expression profiling are under active investigation and present exciting future possibilities. PMID:21171879

  6. Dual-wavelength polarimetric glucose sensing in the presence of birefringence and motion artifact using anterior chamber of the eye phantoms

    PubMed Central

    Pirnstill, Casey W.; Coté, Gerard L.

    2013-01-01

    Abstract. Noninvasive glucose monitoring is being investigated as a tool for effectively managing diabetes mellitus. Optical polarimetry has emerged as one such method, which can potentially be used to ascertain blood glucose levels by measuring the aqueous humor glucose levels in the anterior chamber of the eye. The key limitation for realizing this technique is the presence of sample noise due to corneal birefringence, which in the presence of motion artifact can confound the glucose signature in the aqueous humor of the eye. We present the development and characterization of a real-time, closed-loop, dual-wavelength polarimetric system for glucose monitoring using both a custom-built plastic eye phantom (in vitro) and isolated rabbit corneas (ex vivo) mounted in an artificial anterior chamber. The results show that the system can account for these noise sources and can monitor physiologic glucose levels accurately for a limited range of motion-induced birefringence. Using the dual-wavelength system in vitro and ex vivo, standard errors were 14.5  mg/dL and 22.4  mg/dL, respectively, in the presence of birefringence with motion. The results indicate that although dual-wavelength polarimetry has a limited range of compensation for motion-induced birefringence, when aligned correctly, it can minimize the effect of time-varying corneal birefringence for a range of motion larger than what has been reported in vivo. PMID:23299516

  7. Fetal Heart Rate Monitoring during Intrauterine Open Surgery for Myelomeningocele Repair.

    PubMed

    Santana, Eduardo Félix Martins; Moron, Antônio Fernandes; Barbosa, Maurício Mendes; Milani, Herbene Jose Figuinha; Sarmento, Stephanno Gomes Pereira; Araujo Júnior, Edward; Rolo, Liliam Cristine; Cavalheiro, Sérgio

    2016-01-01

    The aim of this study was to assess fetal hemodynamics during intrauterine open surgery for myelomeningocele (MMC) repair by describing fetal heart rate (FHR) monitoring in detail related to each part of the procedure. A study was performed with 57 fetuses submitted to intrauterine MMC repair between the 24th and 27th week of gestation. Evaluations of FHR were made in specific periods: before anesthesia, after anesthesia, at the beginning of laparotomy, during uterus abdominal withdrawal, hysterotomy, neurosurgery (before incision, during early skin manipulation, spinal cord releasing, and at the end of neurosurgery), abdominal cavity reintroduction, and abdominal closure, and at the end of surgery. Means ± standard deviations of FHR were established for each period, and analysis of variance with repeated measures was used to assess differences between these periods. The mean differences were assessed with 95% confidence intervals and were analyzed by Tukey's multiple comparison test. The mean FHR during the specific periods mentioned above was 140.2, 140, 139.2, 138.8, 135.1, 133.9, 123.1, 134.0, 134.5, 137.9, and 139.9 bpm, respectively (p < 0.0001). Comparing the different periods, the highest frequencies were observed in the initial and final moments. The neurosurgery stage presents lower frequencies, especially during the release of the spinal cord. FHR monitoring revealed interesting findings in terms of physiological fetal changes during MMC repair, especially during neurosurgery, which was the most critical period. © 2015 S. Karger AG, Basel.

  8. Portable microfluidic and smartphone-based devices for monitoring of cardiovascular diseases at the point of care.

    PubMed

    Hu, Jie; Cui, Xingye; Gong, Yan; Xu, Xiayu; Gao, Bin; Wen, Ting; Lu, Tian Jian; Xu, Feng

    2016-01-01

    Cardiovascular diseases (CVDs) are the main causes of morbidity and mortality in the world where about 4 in every 5 CVD deaths happen in low- and middle-income countries (LMICs). Most CVDs are preventable and curable, which is largely dependent on timely and effective interventions, including diagnosis, prognosis and therapeutic monitoring. However, these interventions are high-cost in high income countries and are usually lacking in LMICs. Thanks to the rapid development of microfluidics and nanotechnology, lots of portable analytical devices are developed for detection of CVDs at the point-of-care (POC). In the meantime, smartphone, as a versatile and powerful handheld tool, has been employed not only as a reader for microfluidic assays, but also as an analyzer for physiological indexes. In this review, we present a comprehensive introduction of the current status and potential development direction on POC diagnostics for CVDs. First of all, we introduce some main facts about CVDs and their standard diagnostic procedures and methods. Second, we discuss about both commercially available POC devices and developed prototypes for detection of CVDs via immunoassays. Subsequently, we report the advances in smartphone-based readout for microfluidic assays. Finally, we present some examples using smartphone, individually or combined with other components or devices, for CVD monitoring. We envision an integrated smartphone-based system capable of functioning blood tests, disease examination, and imaging will come in the future. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Reducing motion artifacts for long-term clinical NIRS monitoring using collodion-fixed prism-based optical fibers

    PubMed Central

    Yücel, Meryem A.; Selb, Juliette; Boas, David A.; Cash, Sydney S.; Cooper, Robert J.

    2013-01-01

    As the applications of near-infrared spectroscopy (NIRS) continue to broaden and long-term clinical monitoring becomes more common, minimizing signal artifacts due to patient movement becomes more pressing. This is particularly true in applications where clinically and physiologically interesting events are intrinsically linked to patient movement, as is the case in the study of epileptic seizures. In this study, we apply an approach common in the application of EEG electrodes to the application of specialized NIRS optical fibers. The method provides improved optode-scalp coupling through the use of miniaturized optical fiber tips fixed to the scalp using collodion, a clinical adhesive. We investigate and quantify the performance of this new method in minimizing motion artifacts in healthy subjects, and apply the technique to allow continuous NIRS monitoring throughout epileptic seizures in two epileptic in-patients. Using collodion-fixed fibers reduces the percent signal change of motion artifacts by 90 % and increases the SNR by 6 and 3 fold at 690 and 830 nm wavelengths respectively when compared to a standard Velcro-based array of optical fibers. The change in both HbO and HbR during motion artifacts is found to be statistically lower for the collodion-fixed fiber probe. The collodion-fixed optical fiber approach has also allowed us to obtain good quality NIRS recording of three epileptic seizures in two patients despite excessive motion in each case. PMID:23796546

  10. Ambulatory Monitoring of Congestive Heart Failure by Multiple Bioelectric Impedance Vectors

    PubMed Central

    Khoury, Dirar S.; Naware, Mihir; Siou, Jeff; Blomqvist, Andreas; Mathuria, Nilesh S.; Wang, Jianwen; Shih, Hue-Teh; Nagueh, Sherif F.; Panescu, Dorin

    2009-01-01

    Objectives To investigate properties of multiple bioelectric impedance signals recorded during congestive heart failure (CHF) by utilizing various electrode configurations of an implanted cardiac resynchronization therapy (CRT) system. Background Monitoring of CHF has relied mainly on right-heart sensors. Methods Fifteen normal dogs underwent implantation of CRT systems using standard leads. An additional left atrial (LA) pressure lead-sensor was implanted in 5 dogs. Continuous rapid right ventricular (RV) pacing was applied over several weeks. Left ventricular (LV) catheterization and echocardiography were performed biweekly. Six steady-state impedance signals, utilizing intrathorcaic and intracardiac vectors, were measured via ring (r), coil (c), and device Can electrodes. Results All animals developed CHF after 2–4 weeks of pacing. Impedance diminished gradually during CHF induction, but at varying rates for different vectors. Impedance during CHF decreased significantly in all measured vectors: LVr-Can, −17%; LVr-RVr, −15%; LVr-RAr, −11%; RVr-Can, −12%; RVc-Can, −7%; RAr-Can, −5%. The LVr-Can vector reflected both the fastest and largest change in impedance in comparison to vectors employing only right-heart electrodes, and was highly reflective of changes in LV end-diastolic volume and LA pressure. Conclusions Impedance, acquired via different lead-electrodes, have variable responses to CHF. Impedance vectors employing a LV lead are highly responsive to physiologic changes during CHF. Measuring multiple impedance signals could be useful for optimizing ambulatory monitoring in heart failure patients. PMID:19298923

  11. Practical Application of Fundamental Concepts in Exercise Physiology

    ERIC Educational Resources Information Center

    Ramsbottom R.; Kinch, R. F. T.; Morris, M. G.; Dennis, A. M.

    2007-01-01

    The collection of primary data in laboratory classes enhances undergraduate practical and critical thinking skills. The present article describes the use of a lecture program, running in parallel with a series of linked practical classes, that emphasizes classical or standard concepts in exercise physiology. The academic and practical program ran…

  12. Insomnia with physiological hyperarousal is associated with hypertension.

    PubMed

    Li, Yun; Vgontzas, Alexandros N; Fernandez-Mendoza, Julio; Bixler, Edward O; Sun, Yuanfeng; Zhou, Junying; Ren, Rong; Li, Tao; Tang, Xiangdong

    2015-03-01

    Previous studies have suggested that insomnia with objective short sleep duration is associated with a higher risk of hypertension, and it has been speculated that the underlying mechanism is physiological hyperarousal. In this study, we tested whether insomnia with physiological hyperarousal measured by Multiple Sleep Latency Test (MSLT), a standard test of sleepiness/alertness, is associated with increased risk of hypertension. Two hundred nineteen chronic insomniacs and 96 normal sleepers were included in this study. Chronic insomnia was defined based on standard diagnostic criteria with symptoms lasting ≥6 months. All subjects underwent 1 night in laboratory polysomnography followed by a standard MSLT. We used the median mean MSLT value (ie, >14 minutes) and the 75th percentile of mean MSLT value (ie, >17 minutes) to define hyperarousal. Hypertension was defined based either on blood pressure measures or on diagnosis treatment by a physician. After controlling for age, sex, body mass index, apnea-hypopnea index, diabetes mellitus, smoking, alcohol, and caffeine use, insomnia combined with MSLT >14 minutes increased the odds of hypertension by 300% (odds ratio=3.27; 95% confidence interval=1.20-8.96), whereas insomnia combined with MSLT >17 minutes increased even further the odds of hypertension by 400% (odds ratio=4.33; 95% confidence interval=1.48-12.68) compared with normal sleepers with MSLT ≤14 minutes. Insomnia associated with physiological hyperarousal is associated with a significant risk of hypertension. Long MSLT values may be a reliable index of the physiological hyperarousal and biological severity of chronic insomnia. © 2015 American Heart Association, Inc.

  13. An introduction to the 'Psycho-Physiological-Stress-Test' (PPST)-A standardized instrument for evaluating stress reactions.

    PubMed

    Neureiter, Elisabeth; Hajfani, Loreen; Ahnis, Anne; Mierke, Annett; Rose, Matthias; Danzer, Gerhard; Klapp, Burghard F

    2017-01-01

    Using a standardized instrument to evaluate patients' stress reactions has become more important in daily clinical routines. Different signs or symptoms of stress are often unilaterally explored: the physiological, psychological or social aspects of stress disorders are each viewed on a single dimension. However, all dimensions afflict patients who have persistent health problems due to chronic stress. Therefore, it is important to use a multidimensional approach to acquire data. The 'Psycho-Physiological-Stress-Test' (PPST) was established to achieve a comprehensive understanding of stress and was further developed at the Charité-Universitätsmedizin Berlin in collaboration with the Psychological Department of Freie Universität Berlin. The PPST includes a series of varying stress phases, embedded in two periods of rest. Physiological and psychological parameters are simultaneously measured throughout the test session. Specifically, the PPST activates the sympathetic stress axis, which is measured by heart rate, blood pressure, respiration depth and rate, electro dermal activation and muscle tension (frontalis, masseter, trapezius). Psychological data are simultaneously collected, and include performance, motivation, emotion and behavior. After conducting this diagnostic test, it is possible to identify individual stress patterns that can be discussed with the individual patient to develop and recommend (outpatient) treatment strategies. This paper introduces the PPST as a standardized way to evaluate stress reactions by presenting the results from a sample of psychosomatic inpatients (n = 139) who were treated in Charité-Universitätsmedizin Berlin, Germany. We observed that the varying testing conditions provoked adjusted changes in the different physiological parameters and psychological levels.

  14. The power of clinicians' affective communication: how reassurance about non-abandonment can reduce patients' physiological arousal and increase information recall in bad news consultations. An experimental study using analogue patients.

    PubMed

    Sep, Milou S C; van Osch, Mara; van Vliet, Liesbeth M; Smets, Ellen M A; Bensing, Jozien M

    2014-04-01

    The diagnosis of incurable cancer may evoke physiological arousal in patients. Physiological arousal can negatively impact patients' recall of information provided in the medical consultation. We aim to investigate whether clinicians' affective communication during a bad news consultation will decrease patients' physiological arousal and will improve recall. Healthy women (N=50), acting as analogue patients, were randomly assigned to watch one out of the two versions of a scripted video-vignette of a bad news consultation in which clinician's communication differed: standard vs. affective communication. Participants' skin conductance levels were obtained during video-watching, and afterwards their recall was assessed. While the diagnosis increased skin conductance levels in all analogue patients, skin conductance levels during the remainder of the consultation decreased more in the affective communication condition than in the standard condition. Analogue patients' recall was significantly higher in the affective condition. Breaking bad news evokes physiological arousal. Affective communication can decrease this evoked physiological arousal and might be partly responsible for analogue patients' enhanced information recall. Although our findings need to be translated to clinical patients, they suggest that clinicians need to deal with patients' emotions before providing additional medical information. Copyright © 2014 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  15. Reducing the Primary Cesarean Birth Rate: A Quality Improvement Project.

    PubMed

    Javernick, Julie A; Dempsey, Amy

    2017-07-01

    Research continues to support vaginal birth as the safest mode of childbirth, but despite this, cesarean birth has become the most common surgical procedure performed on women. The rate has increased 500% since the 1970s without a corresponding improvement in maternal or neonatal outcomes. A Colorado community hospital recognized that its primary cesarean birth rate was higher than national and state benchmark levels. To reduce this rate, the hospital collaborated with its largest maternity care provider group to implement a select number of physiologic birth practices and measure improvement in outcomes. Using a pre- and postprocess measure study design, the quality improvement project team identified and implemented 3 physiologic birth parameters over a 12-month period that have been shown to promote vaginal birth. These included reducing elective induction of labor in women less than 41 weeks' gestation; standardizing triage to admit women at greater than or equal to 4 cm dilation; and increasing the use of intermittent auscultation as opposed to continuous fetal monitoring for fetal surveillance. The team also calculated each obstetrician-gynecologist's primary cesarean birth rate monthly and delivered these rates to the providers. Outcomes showed that the provider group decreased its primary cesarean birth rate from 28.9% to 12.2% in the 12-month postprocess measure period. The 57.8% decrease is statistically significant (odds ratio [OR], 0.345; z = 6.52, P < .001; 95% confidence interval [CI], 0.249-0.479). While this quality improvement project cannot be translated to other settings, promotion of physiologic birth practices, along with audit and feedback, had a statistically significant impact on the primary cesarean birth rate for this provider group and, consequently, on the community hospital where they attend births. © 2017 by the American College of Nurse-Midwives.

  16. 28 CFR 115.113 - Supervision and monitoring.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 28 Judicial Administration 2 2014-07-01 2014-07-01 false Supervision and monitoring. 115.113... NATIONAL STANDARDS Standards for Lockups Prevention Planning § 115.113 Supervision and monitoring. (a) For... heightened protection, to include continuous direct sight and sound supervision, single-cell housing, or...

  17. 28 CFR 115.113 - Supervision and monitoring.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 28 Judicial Administration 2 2013-07-01 2013-07-01 false Supervision and monitoring. 115.113... NATIONAL STANDARDS Standards for Lockups Prevention Planning § 115.113 Supervision and monitoring. (a) For... heightened protection, to include continuous direct sight and sound supervision, single-cell housing, or...

  18. 28 CFR 115.113 - Supervision and monitoring.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 28 Judicial Administration 2 2012-07-01 2012-07-01 false Supervision and monitoring. 115.113... NATIONAL STANDARDS Standards for Lockups Prevention Planning § 115.113 Supervision and monitoring. (a) For... heightened protection, to include continuous direct sight and sound supervision, single-cell housing, or...

  19. 40 CFR 60.175 - Monitoring of operations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Primary Zinc... monitor and record the opacity of gases discharged into the atmosphere from any sintering machine. The... volume. (i) The continuous monitoring system performance evaluation required under § 60.13(c) shall be...

  20. [Part II: basic hemodynamic monitoring and the use of pulmonary artery catheter].

    PubMed

    Dias, Fernando Suparregui; Rezende, Ederlon; Mendes, Ciro Leite; Réa-Neto, Alvaro; David, Cid Marcos; Schettino, Guilherme; Lobo, Suzana Margareth Ajeje; Barros, Alberto; Silva, Eliézer; Friedman, Gilberto; Amaral, José Luiz Gomes do; Park, Marcelo; Monachini, Maristela; Oliveira, Mirella Cristine de; Assunção, Murillo Santucci César; Akamine, Nelson; Mello, Patrícia Veiga C; Pereira, Renata Andréa Pietro; Costa Filho, Rubens; Araújo, Sebastião; Félix Pinto, Sérgio; Ferreira, Sérgio; Mitushima, Simone Mattoso; Agareno, Sydney; Brilhante, Yuzeth Nóbrega de Assis

    2006-03-01

    Monitoring of vital functions is one of the most important tools in the management of critically ill patients. Nowadays is possible to detect and analyze a great deal of physiologic data using a lot of invasive and non-invasive methods. The intensivist must be able to select and carry out the most appropriate monitoring technique according to the patient requirements and taking into account the benefit/risk ratio. Despite the fast development of non invasive monitoring techniques, invasive hemodynamic monitoring using Pulmonary Artery Catheter still is one of the basic procedures in Critical Care. The aim was to define recommendations about clinical utility of basic hemodynamic monitoring methods and the Use of Pulmonary Artery Catheter. Modified Delphi methodology was used to create and quantify the consensus between the participants. AMIB indicated a coordinator who invited more six experts in the area of monitoring and hemodynamic support to constitute the Consensus Advisory Board. Twenty-five physicians and nurses selected from different regions of the country completed the expert panel, which reviewed the pertinent bibliography listed at the MEDLINE in the period from 1996 to 2004. Recommendations were made based on 55 questions about the use of central venous pressure, invasive arterial pressure, pulmonary artery catheter and its indications in different settings. Evaluation of central venous pressure and invasive arterial pressure, besides variables obtained by the PAC allow the understanding of cardiovascular physiology that is of great value to the care of critically ill patients. However, the correct use of these tools is fundamental to achieve the benefits due to its use.

  1. Adaptive shut-down of EEG activity predicts critical acidemia in the near-term ovine fetus.

    PubMed

    Frasch, Martin G; Durosier, Lucien Daniel; Gold, Nathan; Cao, Mingju; Matushewski, Brad; Keenliside, Lynn; Louzoun, Yoram; Ross, Michael G; Richardson, Bryan S

    2015-07-01

    In fetal sheep, the electrocorticogram (ECOG) recorded directly from the cortex during repetitive heart rate (FHR) decelerations induced by umbilical cord occlusions (UCO) predictably correlates with worsening hypoxic-acidemia. In human fetal monitoring during labor, the equivalent electroencephalogram (EEG) can be recorded noninvasively from the scalp. We tested the hypothesis that combined fetal EEG - FHR monitoring allows for early detection of worsening hypoxic-acidemia similar to that shown for ECOG-FHR monitoring. Near-term fetal sheep (n = 9) were chronically instrumented with arterial and venous catheters, ECG, ECOG, and EEG electrodes and umbilical cord occluder, followed by 4 days of recovery. Repetitive UCOs of 1 min duration and increasing strength (with regard to the degree of reduction in umbilical blood flow) were induced each 2.5 min until pH dropped to <7.00. Repetitive UCOs led to marked acidosis (arterial pH 7.35 ± 0.01 to 7.00 ± 0.03). At pH of 7.22 ± 0.03 (range 7.32-7.07), and 45 ± 9 min (range 1 h 33 min-20 min) prior to attaining pH < 7.00, both ECOG and EEG amplitudes began to decrease ~fourfold during each FHR deceleration in a synchronized manner. Confirming our hypothesis, these findings support fetal EEG as a useful adjunct to FHR monitoring during human labor for early detection of incipient fetal acidemia. © 2015 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of the American Physiological Society and The Physiological Society.

  2. The Role of Multimodal Invasive Monitoring in Acute Traumatic Brain Injury.

    PubMed

    Lazaridis, Christos; Robertson, Claudia S

    2016-10-01

    This article reviews the role of modalities that directly monitor brain parenchyma in patients with severe traumatic brain injury. The physiology monitored involves compartmental and perfusion pressures, tissue oxygenation and metabolism, quantitative blood flow, pressure autoregulation, and electrophysiology. There are several proposed roles for this multimodality monitoring, such as to track, prevent, and treat the cascade of secondary brain injury; monitor the neurologically injured patient; integrate various data into a composite, patient-specific, and dynamic picture; apply protocolized, pathophysiology-driven intensive care; use as a prognostic marker; and understand pathophysiologic mechanisms involved in secondary brain injury to develop preventive and abortive therapies, and to inform future clinical trials. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Physiological Informatics: Collection and Analyses of Data from Wearable Sensors and Smartphone for Healthcare.

    PubMed

    Bai, Jinwei; Shen, Li; Sun, Huimin; Shen, Bairong

    2017-01-01

    Physiological data from wearable sensors and smartphone are accumulating rapidly, and this provides us the chance to collect dynamic and personalized information as phenotype to be integrated to genotype for the holistic understanding of complex diseases. This integration can be applied to early prediction and prevention of disease, therefore promoting the shifting of disease care tradition to the healthcare paradigm. In this chapter, we summarize the physiological signals which can be detected by wearable sensors, the sharing of the physiological big data, and the mining methods for the discovery of disease-associated patterns for personalized diagnosis and treatment. We discuss the challenges of physiological informatics about the storage, the standardization, the analyses, and the applications of the physiological data from the wearable sensors and smartphone. At last, we present our perspectives on the models for disentangling the complex relationship between early disease prediction and the mining of physiological phenotype data.

  4. A mobile care system with alert mechanism.

    PubMed

    Lee, Ren-Guey; Chen, Kuei-Chien; Hsiao, Chun-Chieh; Tseng, Chwan-Lu

    2007-09-01

    Hypertension and arrhythmia are chronic diseases, which can be effectively prevented and controlled only if the physiological parameters of the patient are constantly monitored, along with the full support of the health education and professional medical care. In this paper, a role-based intelligent mobile care system with alert mechanism in chronic care environment is proposed and implemented. The roles in our system include patients, physicians, nurses, and healthcare providers. Each of the roles represents a person that uses a mobile device such as a mobile phone to communicate with the server setup in the care center such that he or she can go around without restrictions. For commercial mobile phones with Bluetooth communication capability attached to chronic patients, we have developed physiological signal recognition algorithms that were implemented and built-in in the mobile phone without affecting its original communication functions. It is thus possible to integrate several front-end mobile care devices with Bluetooth communication capability to extract patients' various physiological parameters [such as blood pressure, pulse, saturation of haemoglobin (SpO2), and electrocardiogram (ECG)], to monitor multiple physiological signals without space limit, and to upload important or abnormal physiological information to healthcare center for storage and analysis or transmit the information to physicians and healthcare providers for further processing. Thus, the physiological signal extraction devices only have to deal with signal extraction and wireless transmission. Since they do not have to do signal processing, their form factor can be further reduced to reach the goal of microminiaturization and power saving. An alert management mechanism has been included in back-end healthcare center to initiate various strategies for automatic emergency alerts after receiving emergency messages or after automatically recognizing emergency messages. Within the time intervals in system setting, according to the medical history of a specific patient, our prototype system can inform various healthcare providers in sequence to provide healthcare service with their reply to ensure the accuracy of alert information and the completeness of early warning notification to further improve the healthcare quality. In the end, with the testing results and performance evaluation of our implemented system prototype, we conclude that it is possible to set up a complete intelligent healt care chain with mobile monitoring and healthcare service via the assistance of our system.

  5. Reconfigurable wearable to monitor physiological variables and movement

    NASA Astrophysics Data System (ADS)

    Romero, Francisco J.; Morales, Diego P.; Castillo, Encarnación; García, Antonio; Tahmassebi, Amirhessam; Meyer-Baese, Anke

    2017-05-01

    This article presents a preliminary prototype of a wearable instrument for oxygen saturation and ECG monitoring. The proposed measuring system is based on the light reflection variability of a LED emission on the subject temple. Besides, the system has the capacity to incorporate electrodes to obtain ECG measurements. All measurements are stored and transmitted to a mobile device (tablet or smartphone) through a Bluetooth link.

  6. Positron emission tomography probe to monitor selected sugar metabolism in vivo

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Witte, Owen; Clark, Peter M.; Castillo, Blanca Graciela Flores

    The invention disclosed herein discloses selected ribose isomers that are useful as PET probes (e.g. [18F]-2-fluoro-2-deoxy-arabinose). These PET probes are useful, for example, in methods designed to monitor physiological processes including ribose metabolism and/or to selectively observe certain tissue/organs in vivo. The invention disclosed herein further provides methods for making and using such probes.

  7. [Discuss about Alarm Requirements of Standards for Tests of Patient Monitor].

    PubMed

    Feng, Ting

    This paper introduces the alarm requirements of standards of patient monitor and expounds their significance for tests and guidance for patient monitor, then discusses whether technical alarm should not be closed and it latching alarm and non-latching alarm can not exist together.

  8. 40 CFR 63.1023 - Instrument and sensory monitoring for leaks.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... leaks. 63.1023 Section 63.1023 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... (CONTINUED) National Emission Standards for Equipment Leaks-Control Level 2 Standards § 63.1023 Instrument and sensory monitoring for leaks. (a) Monitoring for leaks. The owner or operator of a regulated...

  9. 30 CFR 828.12 - In situ processing: Monitoring.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false In situ processing: Monitoring. 828.12 Section... INTERIOR PERMANENT PROGRAM PERFORMANCE STANDARDS SPECIAL PERMANENT PROGRAM PERFORMANCE STANDARDS-IN SITU PROCESSING § 828.12 In situ processing: Monitoring. (a) Each person who conducts in situ processing...

  10. 30 CFR 828.12 - In situ processing: Monitoring.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 3 2012-07-01 2012-07-01 false In situ processing: Monitoring. 828.12 Section... INTERIOR PERMANENT PROGRAM PERFORMANCE STANDARDS SPECIAL PERMANENT PROGRAM PERFORMANCE STANDARDS-IN SITU PROCESSING § 828.12 In situ processing: Monitoring. (a) Each person who conducts in situ processing...

  11. 30 CFR 828.12 - In situ processing: Monitoring.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 3 2011-07-01 2011-07-01 false In situ processing: Monitoring. 828.12 Section... INTERIOR PERMANENT PROGRAM PERFORMANCE STANDARDS SPECIAL PERMANENT PROGRAM PERFORMANCE STANDARDS-IN SITU PROCESSING § 828.12 In situ processing: Monitoring. (a) Each person who conducts in situ processing...

  12. 30 CFR 828.12 - In situ processing: Monitoring.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 3 2013-07-01 2013-07-01 false In situ processing: Monitoring. 828.12 Section... INTERIOR PERMANENT PROGRAM PERFORMANCE STANDARDS SPECIAL PERMANENT PROGRAM PERFORMANCE STANDARDS-IN SITU PROCESSING § 828.12 In situ processing: Monitoring. (a) Each person who conducts in situ processing...

  13. 30 CFR 828.12 - In situ processing: Monitoring.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 3 2014-07-01 2014-07-01 false In situ processing: Monitoring. 828.12 Section... INTERIOR PERMANENT PROGRAM PERFORMANCE STANDARDS SPECIAL PERMANENT PROGRAM PERFORMANCE STANDARDS-IN SITU PROCESSING § 828.12 In situ processing: Monitoring. (a) Each person who conducts in situ processing...

  14. Role of body-worn movement monitor technology for balance and gait rehabilitation.

    PubMed

    Horak, Fay; King, Laurie; Mancini, Martina

    2015-03-01

    This perspective article will discuss the potential role of body-worn movement monitors for balance and gait assessment and treatment in rehabilitation. Recent advances in inexpensive, wireless sensor technology and smart devices are resulting in an explosion of miniature, portable sensors that can quickly and accurately quantify body motion. Practical and useful movement monitoring systems are now becoming available. It is critical that therapists understand the potential advantages and limitations of such emerging technology. One important advantage of obtaining objective measures of balance and gait from body-worn sensors is impairment-level metrics characterizing how and why functional performance of balance and gait activities are impaired. Therapy can then be focused on the specific physiological reasons for difficulty in walking or balancing during specific tasks. A second advantage of using technology to measure balance and gait behavior is the increased sensitivity of the balance and gait measures to document mild disability and change with rehabilitation. A third advantage of measuring movement, such as postural sway and gait characteristics, with body-worn sensors is the opportunity for immediate biofeedback provided to patients that can focus attention and enhance performance. In the future, body-worn sensors may allow therapists to perform telerehabilitation to monitor compliance with home exercise programs and the quality of their natural mobility in the community. Therapists need technological systems that are quick to use and provide actionable information and useful reports for their patients and referring physicians. Therapists should look for systems that provide measures that have been validated with respect to gold standard accuracy and to clinically relevant outcomes such as fall risk and severity of disability. © 2015 American Physical Therapy Association.

  15. Online monitoring of cartilage tissue in a novel bioreactor

    NASA Astrophysics Data System (ADS)

    von der Burg, E.; von Buttlar, M.; Grill, W.

    2011-04-01

    Standard techniques for the analysis of biological tissues like immunohistochemical staining are typically invasive and lead to mortification of cells. Non-invasive monitoring is an important element of regenerative medicine because implants and components of implants should be 100% quality-checked with non-invasive and therefore also marker-free methods. We report on a new bioreactor for the production of collagen scaffolds seeded with Mesenchymal Stem Cells (MSCs). It contains a computer controlled mechanical activation and ultrasonic online monitoring and has been constructed for the in situ determination of ultrasonic and rheological parameters. During the cultivation period of about two weeks the scaffold is periodically compressed by two movable pistons for improved differentiation of the MSCs. This periodic compression beneficially ensures the supply with nutrition even inside the sample. During the physiological stimuli, rheological properties are measured by means of highly sensitive load cells. In addition measurements of the speed of sound in the sample and in the culture medium, with frequencies up to 16 MHz, are performed continuously. Therefore piezoceramic transducers are attached to the pistons and emit and detect ultrasonic waves, travelling through the pistons, the sample and the culture medium. The time-of-flight (TOF) of the ultrasonic signals is determined in real time with the aid of chirped excitation and correlation procedures with a resolution of at least 10 ps. The implemented ultrasonic measurement scheme allows beside the speed of sound measurements the detection of the distance between the pistons with a resolution better than 100 nm. The developed monitoring delivers information on rigidity, fluid dynamics and velocity of sound in the sample and in the culture medium. The hermetically sealed bioreactor with its life support system provides a biocompatible environment for MSCs for long time cultivation.

  16. Role of Body-Worn Movement Monitor Technology for Balance and Gait Rehabilitation

    PubMed Central

    King, Laurie; Mancini, Martina

    2015-01-01

    This perspective article will discuss the potential role of body-worn movement monitors for balance and gait assessment and treatment in rehabilitation. Recent advances in inexpensive, wireless sensor technology and smart devices are resulting in an explosion of miniature, portable sensors that can quickly and accurately quantify body motion. Practical and useful movement monitoring systems are now becoming available. It is critical that therapists understand the potential advantages and limitations of such emerging technology. One important advantage of obtaining objective measures of balance and gait from body-worn sensors is impairment-level metrics characterizing how and why functional performance of balance and gait activities are impaired. Therapy can then be focused on the specific physiological reasons for difficulty in walking or balancing during specific tasks. A second advantage of using technology to measure balance and gait behavior is the increased sensitivity of the balance and gait measures to document mild disability and change with rehabilitation. A third advantage of measuring movement, such as postural sway and gait characteristics, with body-worn sensors is the opportunity for immediate biofeedback provided to patients that can focus attention and enhance performance. In the future, body-worn sensors may allow therapists to perform telerehabilitation to monitor compliance with home exercise programs and the quality of their natural mobility in the community. Therapists need technological systems that are quick to use and provide actionable information and useful reports for their patients and referring physicians. Therapists should look for systems that provide measures that have been validated with respect to gold standard accuracy and to clinically relevant outcomes such as fall risk and severity of disability. PMID:25504484

  17. Acoustic sensors in the helmet detect voice and physiology

    NASA Astrophysics Data System (ADS)

    Scanlon, Michael V.

    2003-09-01

    The Army Research Laboratory has developed body-contacting acoustic sensors that detect diverse physiological sounds such as heartbeats and breaths, high quality speech, and activity. These sensors use an acoustic impedance-matching gel contained in a soft, compliant pad to enhance the body borne sounds, yet significantly repel airborne noises due to an acoustic impedance mismatch. The signals from such a sensor can be used as a microphone with embedded physiology, or a dedicated digital signal processor can process packetized data to separate physiological parameters from voice, and log parameter trends for performance surveillance. Acoustic sensors were placed inside soldier helmets to monitor voice, physiology, activity, and situational awareness clues such as bullet shockwaves from sniper activity and explosions. The sensors were also incorporated into firefighter breathing masks, neck and wrist straps, and other protective equipment. Heart rate, breath rate, blood pressure, voice and activity can be derived from these sensors (reports at www.arl.army.mil/acoustics). Having numerous sensors at various locations provides a means for array processing to reduce motion artifacts, calculate pulse transit time for passive blood pressure measurement, and the origin of blunt/penetrating traumas such as ballistic wounding. These types of sensors give us the ability to monitor soldiers and civilian emergency first-responders in demanding environments, and provide vital signs information to assess their health status and how that person is interacting with the environment and mission at hand. The Objective Force Warrior, Scorpion, Land Warrior, Warrior Medic, and other military and civilian programs can potentially benefit from these sensors.

  18. Psychophysiological relationships between a multi-component self-report measure of mood, stress and behavioural signs and symptoms, and physiological stress responses during a simulated firefighting deployment.

    PubMed

    Wolkow, Alexander; Aisbett, Brad; Ferguson, Sally A; Reynolds, John; Main, Luana C

    2016-12-01

    Physical work and sleep loss are wildland firefighting demands that elicit psychological and physiological stress responses. Research shows that these responses are statistically related which presents an opportunity to use subjective psychological questionnaires to monitor physiological changes among firefighters; an approach used extensively in sport settings. The aim of the present study was to investigate if changes in self-reported psychological factors on the multi-component training distress scale (MTDS), relate to cytokines and cortisol levels among firefighters completing three days of simulated physical firefighting work separated by an 8-h or restricted 4-h sleep each night. Each day firefighters completed the MTDS in the morning and salivary cortisol and inflammatory cytokines were measured throughout the day. When sleep restricted, firefighters demonstrated increases in MTDS factors of general fatigue, perceived stress and depressed mood that were related to elevated cytokines (TNF-α, IL-8, IL-10). Conversely, firefighters who had an 8-h sleep demonstrated a positive relationship between physical signs and symptoms and elevated IL-6, while depressed mood was inversely related to decreasing cortisol and cytokines (IL-6, TNF-α, IL-10). Findings highlight the utility of the MTDS to detect psychological changes that reflect physiological responses among firefighters. Future research that establishes thresholds for specific factors which predict health-related physiological changes, will allow fire agencies implement multi-component measures to monitor and manage the health of personnel on the fire-ground. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Comparison of Activity Profiles and Physiological Demands Between International Rugby Sevens Matches and Training.

    PubMed

    Higham, Dean G; Pyne, David B; Anson, Judith M; Hopkins, Will G; Eddy, Anthony

    2016-05-01

    The specificity of contemporary training practices of international rugby sevens players is unknown. We quantified the positional group-specific activity profiles and physiological demands of on-field training activities and compared these with match demands. Twenty-two international matches and 63 rugby-specific training drills were monitored in 25 backs and 17 forwards from a national squad of male rugby sevens players over a 21-month period. Drills were classified into 3 categories: low-intensity skill refining (n = 23 drills, 560 observations), moderate- to high-intensity skill refining (n = 28 drills, 600 observations), and game simulation (n = 12 drills, 365 observations). Movement patterns (via Global Positioning System devices) and physiological load (via heart rate monitors) were recorded for all activities, and the differences between training and matches were quantified using magnitude-based inferential statistics. Distance covered in total and at ≥3.5 m·s, maximal velocity, and frequency of accelerations and decelerations were lower for forwards during competition compared with those for backs by a small but practically important magnitude. No clear positional group differences were observed for physiological load during matches. Training demands exceeded match demands only for frequency of decelerations of forwards during moderate- to high-intensity skill-refining drills and only by a small amount. Accelerations and distance covered at ≥6 m·s were closer to match values for forwards than for backs during all training activities, but training drills consistently fell below the demands of international competition. Coaches could therefore improve physical and physiological specificity by increasing the movement demands and intensity of training drills.

  20. Real-time physiological monitoring with distributed networks of sensors and object-oriented programming techniques

    NASA Astrophysics Data System (ADS)

    Wiesmann, William P.; Pranger, L. Alex; Bogucki, Mary S.

    1998-05-01

    Remote monitoring of physiologic data from individual high- risk workers distributed over time and space is a considerable challenge. This is often due to an inadequate capability to accurately integrate large amounts of data into usable information in real time. In this report, we have used the vertical and horizontal organization of the 'fireground' as a framework to design a distributed network of sensors. In this system, sensor output is linked through a hierarchical object oriented programing process to accurately interpret physiological data, incorporate these data into a synchronous model and relay processed data, trends and predictions to members of the fire incident command structure. There are several unique aspects to this approach. The first includes a process to account for variability in vital parameter values for each individual's normal physiologic response by including an adaptive network in each data process. This information is used by the model in an iterative process to baseline a 'normal' physiologic response to a given stress for each individual and to detect deviations that indicate dysfunction or a significant insult. The second unique capability of the system orders the information for each user including the subject, local company officers, medical personnel and the incident commanders. Information can be retrieved and used for training exercises and after action analysis. Finally this system can easily be adapted to existing communication and processing links along with incorporating the best parts of current models through the use of object oriented programming techniques. These modern software techniques are well suited to handling multiple data processes independently over time in a distributed network.

  1. Measurement and Data Transmission Validity of a Multi-Biosensor System for Real-Time Remote Exercise Monitoring Among Cardiac Patients.

    PubMed

    Rawstorn, Jonathan C; Gant, Nicholas; Warren, Ian; Doughty, Robert Neil; Lever, Nigel; Poppe, Katrina K; Maddison, Ralph

    2015-03-20

    Remote telemonitoring holds great potential to augment management of patients with coronary heart disease (CHD) and atrial fibrillation (AF) by enabling regular physiological monitoring during physical activity. Remote physiological monitoring may improve home and community exercise-based cardiac rehabilitation (exCR) programs and could improve assessment of the impact and management of pharmacological interventions for heart rate control in individuals with AF. Our aim was to evaluate the measurement validity and data transmission reliability of a remote telemonitoring system comprising a wireless multi-parameter physiological sensor, custom mobile app, and middleware platform, among individuals in sinus rhythm and AF. Participants in sinus rhythm and with AF undertook simulated daily activities, low, moderate, and/or high intensity exercise. Remote monitoring system heart rate and respiratory rate were compared to reference measures (12-lead ECG and indirect calorimeter). Wireless data transmission loss was calculated between the sensor, mobile app, and remote Internet server. Median heart rate (-0.30 to 1.10 b∙min -1 ) and respiratory rate (-1.25 to 0.39 br∙min -1 ) measurement biases were small, yet statistically significant (all P≤.003) due to the large number of observations. Measurement reliability was generally excellent (rho=.87-.97, all P<.001; intraclass correlation coefficient [ICC]=.94-.98, all P<.001; coefficient of variation [CV]=2.24-7.94%), although respiratory rate measurement reliability was poor among AF participants (rho=.43, P<.001; ICC=.55, P<.001; CV=16.61%). Data loss was minimal (<5%) when all system components were active; however, instability of the network hosting the remote data capture server resulted in data loss at the remote Internet server during some trials. System validity was sufficient for remote monitoring of heart and respiratory rates across a range of exercise intensities. Remote exercise monitoring has potential to augment current exCR and heart rate control management approaches by enabling the provision of individually tailored care to individuals outside traditional clinical environments. ©Jonathan C Rawstorn, Nicholas Gant, Ian Warren, Robert Neil Doughty, Nigel Lever, Katrina K Poppe, Ralph Maddison. Originally published in JMIR Rehabilitation and Assistive Technology (http://rehab.jmir.org), 20.03.2015.

  2. 40 CFR 192.03 - Monitoring.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... AND ENVIRONMENTAL PROTECTION STANDARDS FOR URANIUM AND THORIUM MILL TAILINGS Standards for the Control of Residual Radioactive Materials from Inactive Uranium Processing Sites § 192.03 Monitoring. A...

  3. 40 CFR 192.03 - Monitoring.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... AND ENVIRONMENTAL PROTECTION STANDARDS FOR URANIUM AND THORIUM MILL TAILINGS Standards for the Control of Residual Radioactive Materials from Inactive Uranium Processing Sites § 192.03 Monitoring. A...

  4. 40 CFR 192.03 - Monitoring.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... AND ENVIRONMENTAL PROTECTION STANDARDS FOR URANIUM AND THORIUM MILL TAILINGS Standards for the Control of Residual Radioactive Materials from Inactive Uranium Processing Sites § 192.03 Monitoring. A...

  5. 40 CFR 192.03 - Monitoring.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... AND ENVIRONMENTAL PROTECTION STANDARDS FOR URANIUM AND THORIUM MILL TAILINGS Standards for the Control of Residual Radioactive Materials from Inactive Uranium Processing Sites § 192.03 Monitoring. A...

  6. The role of physiology in the development of golf performance.

    PubMed

    Smith, Mark F

    2010-08-01

    The attainment of consistent high performance in golf requires effective physical conditioning that is carefully designed and monitored in accordance with the on-course demands the player will encounter. Appreciating the role that physiology plays in the attainment of consistent performance, and how a player's physicality can inhibit performance progression, supports the notion that the application of physiology is fundamental for any player wishing to excel in golf. With cardiorespiratory, metabolic, hormonal, musculoskeletal and nutritional demands acting on the golfer within and between rounds, effective physical screening of a player will ensure physiological and anatomical deficiencies that may influence performance are highlighted. The application of appropriate golf-specific assessment methods will ensure that physical attributes that have a direct effect on golf performance can be measured reliably and accurately. With the physical development of golf performance being achieved through a process of conditioning with the purpose of inducing changes in structural and metabolic functions, training must focus on foundation whole-body fitness and golf-specific functional strength and flexibility activities. For long-term player improvement to be effective, comprehensive monitoring will ensure the player reaches an optimal physical state at predetermined times in the competitive season. Through continual assessment of a player's physical attributes, training effectiveness and suitability, and the associated adaptive responses, key physical factors that may impact most on performance success can be determined.

  7. A wearable biochemical sensor for monitoring alcohol consumption lifestyle through Ethyl glucuronide (EtG) detection in human sweat.

    PubMed

    Selvam, Anjan Panneer; Muthukumar, Sriram; Kamakoti, Vikramshankar; Prasad, Shalini

    2016-03-21

    We demonstrate for the first time a wearable biochemical sensor for monitoring alcohol consumption through the detection and quantification of a metabolite of ethanol, ethyl glucuronide (EtG). We designed and fabricated two co-planar sensors with gold and zinc oxide as sensing electrodes. We also designed a LED based reporting for the presence of EtG in the human sweat samples. The sensor functions on affinity based immunoassay principles whereby monoclonal antibodies for EtG were immobilized on the electrodes using thiol based chemistry. Detection of EtG from human sweat was achieved through chemiresistive sensing mechanism. In this method, an AC voltage was applied across the two coplanar electrodes and the impedance across the sensor electrodes was measured and calibrated for physiologically relevant doses of EtG in human sweat. EtG detection over a dose concentration of 0.001-100 μg/L was demonstrated on both glass and polyimide substrates. Detection sensitivity was lower at 1 μg/L with gold electrodes as compared to ZnO, which had detection sensitivity of 0.001 μg/L. Based on the detection range the wearable sensor has the ability to detect alcohol consumption of up to 11 standard drinks in the US over a period of 4 to 9 hours.

  8. Battery-free, stretchable optoelectronic systems for wireless optical characterization of the skin

    PubMed Central

    Kim, Jeonghyun; Salvatore, Giovanni A.; Araki, Hitoshi; Chiarelli, Antonio M.; Xie, Zhaoqian; Banks, Anthony; Sheng, Xing; Liu, Yuhao; Lee, Jung Woo; Jang, Kyung-In; Heo, Seung Yun; Cho, Kyoungyeon; Luo, Hongying; Zimmerman, Benjamin; Kim, Joonhee; Yan, Lingqing; Feng, Xue; Xu, Sheng; Fabiani, Monica; Gratton, Gabriele; Huang, Yonggang; Paik, Ungyu; Rogers, John A.

    2016-01-01

    Recent advances in materials, mechanics, and electronic device design are rapidly establishing the foundations for health monitoring technologies that have “skin-like” properties, with options in chronic (weeks) integration with the epidermis. The resulting capabilities in physiological sensing greatly exceed those possible with conventional hard electronic systems, such as those found in wrist-mounted wearables, because of the intimate skin interface. However, most examples of such emerging classes of devices require batteries and/or hard-wired connections to enable operation. The work reported here introduces active optoelectronic systems that function without batteries and in an entirely wireless mode, with examples in thin, stretchable platforms designed for multiwavelength optical characterization of the skin. Magnetic inductive coupling and near-field communication (NFC) schemes deliver power to multicolored light-emitting diodes and extract digital data from integrated photodetectors in ways that are compatible with standard NFC-enabled platforms, such as smartphones and tablet computers. Examples in the monitoring of heart rate and temporal dynamics of arterial blood flow, in quantifying tissue oxygenation and ultraviolet dosimetry, and in performing four-color spectroscopic evaluation of the skin demonstrate the versatility of these concepts. The results have potential relevance in both hospital care and at-home diagnostics. PMID:27493994

  9. Mining Missing Membrane Proteins by High-pH Reverse-Phase StageTip Fractionation and Multiple Reaction Monitoring Mass Spectrometry.

    PubMed

    Kitata, Reta Birhanu; Dimayacyac-Esleta, Baby Rorielyn T; Choong, Wai-Kok; Tsai, Chia-Feng; Lin, Tai-Du; Tsou, Chih-Chiang; Weng, Shao-Hsing; Chen, Yi-Ju; Yang, Pan-Chyr; Arco, Susan D; Nesvizhskii, Alexey I; Sung, Ting-Yi; Chen, Yu-Ju

    2015-09-04

    Despite significant efforts in the past decade toward complete mapping of the human proteome, 3564 proteins (neXtProt, 09-2014) are still "missing proteins". Over one-third of these missing proteins are annotated as membrane proteins, owing to their relatively challenging accessibility with standard shotgun proteomics. Using nonsmall cell lung cancer (NSCLC) as a model study, we aim to mine missing proteins from disease-associated membrane proteome, which may be still largely under-represented. To increase identification coverage, we employed Hp-RP StageTip prefractionation of membrane-enriched samples from 11 NSCLC cell lines. Analysis of membrane samples from 20 pairs of tumor and adjacent normal lung tissue was incorporated to include physiologically expressed membrane proteins. Using multiple search engines (X!Tandem, Comet, and Mascot) and stringent evaluation of FDR (MAYU and PeptideShaker), we identified 7702 proteins (66% membrane proteins) and 178 missing proteins (74 membrane proteins) with PSM-, peptide-, and protein-level FDR of 1%. Through multiple reaction monitoring using synthetic peptides, we provided additional evidence of eight missing proteins including seven with transmembrane helix domains. This study demonstrates that mining missing proteins focused on cancer membrane subproteome can greatly contribute to map the whole human proteome. All data were deposited into ProteomeXchange with the identifier PXD002224.

  10. Comparison of scientific CMOS camera and webcam for monitoring cardiac pulse after exercise

    NASA Astrophysics Data System (ADS)

    Sun, Yu; Papin, Charlotte; Azorin-Peris, Vicente; Kalawsky, Roy; Greenwald, Stephen; Hu, Sijung

    2011-09-01

    In light of its capacity for remote physiological assessment over a wide range of anatomical locations, imaging photoplethysmography has become an attractive research area in biomedical and clinical community. Amongst recent iPPG studies, two separate research directions have been revealed, i.e., scientific camera based imaging PPG (iPPG) and webcam based imaging PPG (wPPG). Little is known about the difference between these two techniques. To address this issue, a dual-channel imaging PPG system (iPPG and wPPG) using ambient light as the illumination source has been introduced in this study. The performance of the two imaging PPG techniques was evaluated through the measurement of cardiac pulse acquired from the face of 10 male subjects before and after 10 min of cycling exercise. A time-frequency representation method was used to visualize the time-dependent behaviour of the heart rate. In comparison to the gold standard contact PPG, both imaging PPG techniques exhibit comparable functional characteristics in the context of cardiac pulse assessment. Moreover, the synchronized ambient light intensity recordings in the present study can provide additional information for appraising the performance of the imaging PPG systems. This feasibility study thereby leads to a new route for non-contact monitoring of vital signs, with clear applications in triage and homecare.

  11. Closed Ecological Life Support Systems (CELSS) Test Facility

    NASA Technical Reports Server (NTRS)

    Macelroy, Robert D.

    1992-01-01

    The CELSS Test Facility (CTF) is being developed for installation on Space Station Freedom (SSF) in August 1999. It is designed to conduct experiments that will determine the effects of microgravity on the productivity of higher (crop) plants. The CTF will occupy two standard SSF racks and will accommodate approximately one square meter of growing area and a canopy height of 80 cm. The growth volume will be isolated from the external environment, allowing stringent control of environmental conditions. Temperature, humidity, oxygen, carbon dioxide, and light levels will all be closely controlled to prescribed set points and monitored. This level of environmental control is needed to prevent stress and allow accurate assessment of microgravity effect (10-3 to 10-6 x g). Photosynthetic rates and respiration rates, calculated through continuous recording of gas concentrations, transpiration, and total and edible biomass produced will be measured. Toxic byproducts will be monitored and scrubbed. Transpiration water will be collected within the chamber and recycled into the nutrient solution. A wide variety of crop plants, e.g., wheat, soy beans, lettuce, potatoes, can be accommodated and various nutrient delivery systems and light delivery systems will be available. In the course of its development, the CTF will exploit fully, and contribute importantly, to the state-of-art in closed system technology and plant physiology.

  12. Live Cells as Dynamic Laboratories: Time Lapse Raman Spectral Microscopy of Nanoparticles with Both IgE Targeting and pH-Sensing Functions

    DOE PAGES

    Nowak-Lovato, Kristy L.; Rector, Kirk D.

    2012-01-01

    Tmore » his review captures the use of live cells as dynamic microlaboratories through implementation of labeled nanoparticles (nanosensors) that have both sensing and targeting functions. he addition of 2,4-ε-dinitrophenol-L-lysine (DNP) as a FcεRI targeting ligand and 4-mercaptopyridine (4-MPy) as a pH-sensing ligand enables spatial and temporal monitoring of FcεRI receptors and their pH environment within the endocytic pathway. o ensure reliability, the sensor is calibrated in vivo using the ionophore nigericin and standard buffer solutions to equilibrate the external [ H + ] concentration with that of the cell compartments. his review highlights the nanosensors, ability to traffic and respond to pH of receptor-bound nanosensors (1) at physiological temperature ( 37 ° C ) versus room temperature ( 25 ° C ) , (2) after pharmacological treatment with bafilomycin, an H + APase pump inhibitor, or amiloride, an inhibitor of Na + / H + exchange, and (3) in response to both temperature and pharmacological treatment. Whole-cell, time lapse images are demonstrated to show the ability to transform live cells into dynamic laboratories to monitor temporal and spatial endosomal pH. he versatility of these probes shows promise for future applications relevant to intracellular trafficking and intelligent drug design.« less

  13. Performance evaluation of an infrared thermocouple.

    PubMed

    Chen, Chiachung; Weng, Yu-Kai; Shen, Te-Ching

    2010-01-01

    The measurement of the leaf temperature of forests or agricultural plants is an important technique for the monitoring of the physiological state of crops. The infrared thermometer is a convenient device due to its fast response and nondestructive measurement technique. Nowadays, a novel infrared thermocouple, developed with the same measurement principle of the infrared thermometer but using a different detector, has been commercialized for non-contact temperature measurement. The performances of two-kinds of infrared thermocouples were evaluated in this study. The standard temperature was maintained by a temperature calibrator and a special black cavity device. The results indicated that both types of infrared thermocouples had good precision. The error distribution ranged from -1.8 °C to 18 °C as the reading values served as the true values. Within the range from 13 °C to 37 °C, the adequate calibration equations were the high-order polynomial equations. Within the narrower range from 20 °C to 35 °C, the adequate equation was a linear equation for one sensor and a two-order polynomial equation for the other sensor. The accuracy of the two kinds of infrared thermocouple was improved by nearly 0.4 °C with the calibration equations. These devices could serve as mobile monitoring tools for in situ and real time routine estimation of leaf temperatures.

  14. Methods and applications of HPLC-AMS (WBio 5)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bucholz, B A; Clifford, A J; Duecker, S R

    Pharmacokinetics of physiologic doses of nutrients, pesticides, and herbicides can easily be traced in humans using a {sup 14}C-labelled compound. Basic kinetics can be monitored in blood or urine by measuring the elevation in the {sup 14}C content above the control predose tissue and converting to equivalents of the parent compound. High Performance Liquid Chromatography (HPLC) is an excellent method for the chemical separation of complex mixtures whose profiles afford estimation of biochemical pathways of metabolism. Compounds elute from the HPLC systems with characteristic retention times and can be collected in fractions that can then be graphitized for AMS measurement.more » Unknowns are identified by coelution with known standards and chemical tests that reveal functional groupings. Metabolites are quantified with the {sup 14}C signal. Thoroughly accounting for the carbon inventory in the LC solvents, ion-pairing agents, samples, and carriers adds some complexity to the analysis. In most cases the total carbon inventory is dominated by carrier. Baseline background and stability need to be carefully monitored. Limits of quantitation near 10 amol of {sup 14}C per HPLC fraction are typically achieved. Baselines are maintained by limiting injected {sup 14}C activity <0.17 Bq (4.5 pCi) on the HPLC column.« less

  15. 40 CFR 60.423 - Monitoring of operations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Ammonium Sulfate Manufacture § 60.423 Monitoring of operations. (a) The owner or operator of any ammonium sulfate manufacturing... monitoring devices which can be used to determine the mass flow of ammonium sulfate feed material streams to...

  16. 40 CFR 60.423 - Monitoring of operations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Ammonium Sulfate Manufacture § 60.423 Monitoring of operations. (a) The owner or operator of any ammonium sulfate manufacturing... monitoring devices which can be used to determine the mass flow of ammonium sulfate feed material streams to...

  17. 40 CFR 60.423 - Monitoring of operations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Ammonium Sulfate Manufacture § 60.423 Monitoring of operations. (a) The owner or operator of any ammonium sulfate manufacturing... monitoring devices which can be used to determine the mass flow of ammonium sulfate feed material streams to...

  18. 40 CFR 60.423 - Monitoring of operations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Ammonium Sulfate Manufacture § 60.423 Monitoring of operations. (a) The owner or operator of any ammonium sulfate manufacturing... monitoring devices which can be used to determine the mass flow of ammonium sulfate feed material streams to...

  19. 40 CFR 60.423 - Monitoring of operations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Ammonium Sulfate Manufacture § 60.423 Monitoring of operations. (a) The owner or operator of any ammonium sulfate manufacturing... monitoring devices which can be used to determine the mass flow of ammonium sulfate feed material streams to...

  20. Soil quality monitoring: Examples of existing protocols

    Treesearch

    Daniel G. Neary; Carl C. Trettin; Deborah Page-Dumroese

    2010-01-01

    Many forestry and agricultural agencies and organizations worldwide have developed soil monitoring and quality standards and guidelines to ensure future sustainability of land management. These soil monitoring standards are typically developed in response to international initiatives such as the Montreal Process, the Helsinki Ministerial Conference,or in support of...

Top