Sample records for standard reference model

  1. Reference and Standard Atmosphere Models

    NASA Technical Reports Server (NTRS)

    Johnson, Dale L.; Roberts, Barry C.; Vaughan, William W.; Parker, Nelson C. (Technical Monitor)

    2002-01-01

    This paper describes the development of standard and reference atmosphere models along with the history of their origin and use since the mid 19th century. The first "Standard Atmospheres" were established by international agreement in the 1920's. Later some countries, notably the United States, also developed and published "Standard Atmospheres". The term "Reference Atmospheres" is used to identify atmosphere models for specific geographical locations. Range Reference Atmosphere Models developed first during the 1960's are examples of these descriptions of the atmosphere. This paper discusses the various models, scopes, applications and limitations relative to use in aerospace industry activities.

  2. A standard satellite control reference model

    NASA Technical Reports Server (NTRS)

    Golden, Constance

    1994-01-01

    This paper describes a Satellite Control Reference Model that provides the basis for an approach to identify where standards would be beneficial in supporting space operations functions. The background and context for the development of the model and the approach are described. A process for using this reference model to trace top level interoperability directives to specific sets of engineering interface standards that must be implemented to meet these directives is discussed. Issues in developing a 'universal' reference model are also identified.

  3. Digital data registration and differencing compression system

    NASA Technical Reports Server (NTRS)

    Ransford, Gary A. (Inventor); Cambridge, Vivien J. (Inventor)

    1990-01-01

    A process is disclosed for x ray registration and differencing which results in more efficient compression. Differencing of registered modeled subject image with a modeled reference image forms a differenced image for compression with conventional compression algorithms. Obtention of a modeled reference image includes modeling a relatively unrelated standard reference image upon a three-dimensional model, which three-dimensional model is also used to model the subject image for obtaining the modeled subject image. The registration process of the modeled subject image and modeled reference image translationally correlates such modeled images for resulting correlation thereof in spatial and spectral dimensions. Prior to compression, a portion of the image falling outside a designated area of interest may be eliminated, for subsequent replenishment with a standard reference image. The compressed differenced image may be subsequently transmitted and/or stored, for subsequent decompression and addition to a standard reference image so as to form a reconstituted or approximated subject image at either a remote location and/or at a later moment in time. Overall effective compression ratios of 100:1 are possible for thoracic x ray digital images.

  4. Digital Data Registration and Differencing Compression System

    NASA Technical Reports Server (NTRS)

    Ransford, Gary A. (Inventor); Cambridge, Vivien J. (Inventor)

    1996-01-01

    A process for X-ray registration and differencing results in more efficient compression. Differencing of registered modeled subject image with a modeled reference image forms a differenced image for compression with conventional compression algorithms. Obtention of a modeled reference image includes modeling a relatively unrelated standard reference image upon a three-dimensional model, which three-dimensional model is also used to model the subject image for obtaining the modeled subject image. The registration process of the modeled subject image and modeled reference image translationally correlates such modeled images for resulting correlation thereof in spatial and spectral dimensions. Prior to compression, a portion of the image falling outside a designated area of interest may be eliminated, for subsequent replenishment with a standard reference image. The compressed differenced image may be subsequently transmitted and/or stored, for subsequent decompression and addition to a standard reference image so as to form a reconstituted or approximated subject image at either a remote location and/or at a later moment in time. Overall effective compression ratios of 100:1 are possible for thoracic X-ray digital images.

  5. Digital data registration and differencing compression system

    NASA Technical Reports Server (NTRS)

    Ransford, Gary A. (Inventor); Cambridge, Vivien J. (Inventor)

    1992-01-01

    A process for x ray registration and differencing results in more efficient compression is discussed. Differencing of registered modeled subject image with a modeled reference image forms a differential image for compression with conventional compression algorithms. Obtention of a modeled reference image includes modeling a relatively unrelated standard reference image upon a three dimensional model, which three dimensional model is also used to model the subject image for obtaining the modeled subject image. The registration process of the modeled subject image and modeled reference image translationally correlates such modeled images for resulting correlation thereof in spatial and spectral dimensions. Prior to compression, a portion of the image falling outside a designated area of interest may be eliminated, for subsequent replenishment with a standard reference image. The compressed differenced image may be subsequently transmitted and/or stored, for subsequent decompression and addition to a standard reference image so as to form a reconstituted or approximated subject image at either remote location and/or at a later moment in time. Overall effective compression ratios of 100:1 are possible for thoracic x ray digital images.

  6. Panel C report: Standards needed for the use of ISO Open Systems Interconnection - basic reference model

    NASA Technical Reports Server (NTRS)

    1981-01-01

    The use of an International Standards Organization (ISO) Open Systems Interconnection (OSI) Reference Model and its relevance to interconnecting an Applications Data Service (ADS) pilot program for data sharing is discussed. A top level mapping between the conjectured ADS requirements and identified layers within the OSI Reference Model was performed. It was concluded that the OSI model represents an orderly architecture for the ADS networking planning and that the protocols being developed by the National Bureau of Standards offer the best available implementation approach.

  7. Clinical diagnostic model for sciatica developed in primary care patients with low back-related leg pain

    PubMed Central

    Konstantinou, Kika; Ogollah, Reuben; Hay, Elaine M.; Dunn, Kate M.

    2018-01-01

    Background Identification of sciatica may assist timely management but can be challenging in clinical practice. Diagnostic models to identify sciatica have mainly been developed in secondary care settings with conflicting reference standard selection. This study explores the challenges of reference standard selection and aims to ascertain which combination of clinical assessment items best identify sciatica in people seeking primary healthcare. Methods Data on 394 low back-related leg pain consulters were analysed. Potential sciatica indicators were seven clinical assessment items. Two reference standards were used: (i) high confidence sciatica clinical diagnosis; (ii) high confidence sciatica clinical diagnosis with confirmatory magnetic resonance imaging findings. Multivariable logistic regression models were produced for both reference standards. A tool predicting sciatica diagnosis in low back-related leg pain was derived. Latent class modelling explored the validity of the reference standard. Results Model (i) retained five items; model (ii) retained six items. Four items remained in both models: below knee pain, leg pain worse than back pain, positive neural tension tests and neurological deficit. Model (i) was well calibrated (p = 0.18), discrimination was area under the receiver operating characteristic curve (AUC) 0.95 (95% CI 0.93, 0.98). Model (ii) showed good discrimination (AUC 0.82; 0.78, 0.86) but poor calibration (p = 0.004). Bootstrapping revealed minimal overfitting in both models. Agreement between the two latent classes and clinical diagnosis groups defined by model (i) was substantial, and fair for model (ii). Conclusion Four clinical assessment items were common in both reference standard definitions of sciatica. A simple scoring tool for identifying sciatica was developed. These criteria could be used clinically and in research to improve accuracy of identification of this subgroup of back pain patients. PMID:29621243

  8. Guide to solar reference spectra and irradiance models

    NASA Astrophysics Data System (ADS)

    Tobiska, W. Kent

    The international standard for determining solar irradiances was published by the International Standards Organization (ISO) in May 2007. The document, ISO 21348 Space Environment (natural and artificial) - Process for determining solar irradiances, describes the process for representing solar irradiances. We report on the next progression of standards work, i.e., the development of a guide that identifies solar reference spectra and irradiance models for use in engineering design or scientific research. This document will be produced as an AIAA Guideline and ISO Technical Report. It will describe the content of the reference spectra and models, uncertainties and limitations, technical basis, data bases from which the reference spectra and models are formed, publication references, and sources of computer code for reference spectra and solar irradiance models, including those which provide spectrally-resolved lines as well as solar indices and proxies and which are generally recognized in the solar sciences. The document is intended to assist aircraft and space vehicle designers and developers, heliophysicists, geophysicists, aeronomers, meteorologists, and climatologists in understanding available models, comparing sources of data, and interpreting engineering and scientific results based on different solar reference spectra and irradiance models.

  9. Selection of reference standard during method development using the analytical hierarchy process.

    PubMed

    Sun, Wan-yang; Tong, Ling; Li, Dong-xiang; Huang, Jing-yi; Zhou, Shui-ping; Sun, Henry; Bi, Kai-shun

    2015-03-25

    Reference standard is critical for ensuring reliable and accurate method performance. One important issue is how to select the ideal one from the alternatives. Unlike the optimization of parameters, the criteria of the reference standard are always immeasurable. The aim of this paper is to recommend a quantitative approach for the selection of reference standard during method development based on the analytical hierarchy process (AHP) as a decision-making tool. Six alternative single reference standards were assessed in quantitative analysis of six phenolic acids from Salvia Miltiorrhiza and its preparations by using ultra-performance liquid chromatography. The AHP model simultaneously considered six criteria related to reference standard characteristics and method performance, containing feasibility to obtain, abundance in samples, chemical stability, accuracy, precision and robustness. The priority of each alternative was calculated using standard AHP analysis method. The results showed that protocatechuic aldehyde is the ideal reference standard, and rosmarinic acid is about 79.8% ability as the second choice. The determination results successfully verified the evaluation ability of this model. The AHP allowed us comprehensive considering the benefits and risks of the alternatives. It was an effective and practical tool for optimization of reference standards during method development. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Designing image segmentation studies: Statistical power, sample size and reference standard quality.

    PubMed

    Gibson, Eli; Hu, Yipeng; Huisman, Henkjan J; Barratt, Dean C

    2017-12-01

    Segmentation algorithms are typically evaluated by comparison to an accepted reference standard. The cost of generating accurate reference standards for medical image segmentation can be substantial. Since the study cost and the likelihood of detecting a clinically meaningful difference in accuracy both depend on the size and on the quality of the study reference standard, balancing these trade-offs supports the efficient use of research resources. In this work, we derive a statistical power calculation that enables researchers to estimate the appropriate sample size to detect clinically meaningful differences in segmentation accuracy (i.e. the proportion of voxels matching the reference standard) between two algorithms. Furthermore, we derive a formula to relate reference standard errors to their effect on the sample sizes of studies using lower-quality (but potentially more affordable and practically available) reference standards. The accuracy of the derived sample size formula was estimated through Monte Carlo simulation, demonstrating, with 95% confidence, a predicted statistical power within 4% of simulated values across a range of model parameters. This corresponds to sample size errors of less than 4 subjects and errors in the detectable accuracy difference less than 0.6%. The applicability of the formula to real-world data was assessed using bootstrap resampling simulations for pairs of algorithms from the PROMISE12 prostate MR segmentation challenge data set. The model predicted the simulated power for the majority of algorithm pairs within 4% for simulated experiments using a high-quality reference standard and within 6% for simulated experiments using a low-quality reference standard. A case study, also based on the PROMISE12 data, illustrates using the formulae to evaluate whether to use a lower-quality reference standard in a prostate segmentation study. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  11. Standard surface-reflectance model and illuminant estimation

    NASA Technical Reports Server (NTRS)

    Tominaga, Shoji; Wandell, Brian A.

    1989-01-01

    A vector analysis technique was adopted to test the standard reflectance model. A computational model was developed to determine the components of the observed spectra and an estimate of the illuminant was obtained without using a reference white standard. The accuracy of the standard model is evaluated.

  12. ANSI/ASHRAE/IES Standard 90.1-2010 Performance Rating Method Reference Manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goel, Supriya; Rosenberg, Michael I.

    This document is intended to be a reference manual for the Appendix G Performance Rating Method (PRM) of ANSI/ASHRAE/IES Standard 90.1- 2010 (Standard 90.1-2010).The PRM is used for rating the energy efficiency of commercial and high-rise residential buildings with designs that exceed the requirements of Standard 90.1. The procedures and processes described in this manual are designed to provide consistency and accuracy by filling in gaps and providing additional details needed by users of the PRM. It should be noted that this document is created independently from ASHRAE and SSPC 90.1 and is not sanctioned nor approved by either ofmore » those entities . Potential users of this manual include energy modelers, software developers and implementers of “beyond code” energy programs. Energy modelers using ASHRAE Standard 90.1-2010 for beyond code programs can use this document as a reference manual for interpreting requirements of the Performance Rating method. Software developers, developing tools for automated creation of the baseline model can use this reference manual as a guideline for developing the rules for the baseline model.« less

  13. 46 CFR 160.005-1 - Incorporation by reference.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...), Models 52 and 56 § 160.005-1 Incorporation by reference. (a) Specifications and Standards. This subpart... Guard. The Federal specifications and standards may be purchased from the Business Service Center...

  14. The American Archival Profession and Information Technology Standards.

    ERIC Educational Resources Information Center

    Cox, Richard J.

    1992-01-01

    Discussion of the use of standards by archivists highlights the U.S. MARC AMC (Archives-Manuscript Control) format for reporting archival records and manuscripts; their interest in specific standards being developed for the OSI (Open Systems Interconnection) reference model; and the management of records in electronic formats. (16 references) (LAE)

  15. Integration of nursing assessment concepts into the medical entities dictionary using the LOINC semantic structure as a terminology model.

    PubMed

    Cieslowski, B J; Wajngurt, D; Cimino, J J; Bakken, S

    2001-01-01

    Recent investigations have tested the applicability of various terminology models for the representing nursing concepts including those related to nursing diagnoses, nursing interventions, and standardized nursing assessments as a prerequisite for building a reference terminology that supports the nursing domain. We used the semantic structure of Clinical LOINC (Logical Observations, Identifiers, Names, and Codes) as a reference terminology model to support the integration of standardized assessment terms from two nursing terminologies into the Medical Entities Dictionary (MED), the concept-oriented, metadata dictionary at New York Presbyterian Hospital. Although the LOINC semantic structure was used previously to represent laboratory terms in the MED, selected hierarchies and semantic slots required revisions in order to incorporate the nursing assessment concepts. This project was an initial step in integrating nursing assessment concepts into the MED in a manner consistent with evolving standards for reference terminology models. Moreover, the revisions provide the foundation for adding other types of standardized assessments to the MED.

  16. Integration of nursing assessment concepts into the medical entities dictionary using the LOINC semantic structure as a terminology model.

    PubMed Central

    Cieslowski, B. J.; Wajngurt, D.; Cimino, J. J.; Bakken, S.

    2001-01-01

    Recent investigations have tested the applicability of various terminology models for the representing nursing concepts including those related to nursing diagnoses, nursing interventions, and standardized nursing assessments as a prerequisite for building a reference terminology that supports the nursing domain. We used the semantic structure of Clinical LOINC (Logical Observations, Identifiers, Names, and Codes) as a reference terminology model to support the integration of standardized assessment terms from two nursing terminologies into the Medical Entities Dictionary (MED), the concept-oriented, metadata dictionary at New York Presbyterian Hospital. Although the LOINC semantic structure was used previously to represent laboratory terms in the MED, selected hierarchies and semantic slots required revisions in order to incorporate the nursing assessment concepts. This project was an initial step in integrating nursing assessment concepts into the MED in a manner consistent with evolving standards for reference terminology models. Moreover, the revisions provide the foundation for adding other types of standardized assessments to the MED. PMID:11825165

  17. A reference model for space data system interconnection services

    NASA Astrophysics Data System (ADS)

    Pietras, John; Theis, Gerhard

    1993-03-01

    The widespread adoption of standard packet-based data communication protocols and services for spaceflight missions provides the foundation for other standard space data handling services. These space data handling services can be defined as increasingly sophisticated processing of data or information received from lower-level services, using a layering approach made famous in the International Organization for Standardization (ISO) Open System Interconnection Reference Model (OSI-RM). The Space Data System Interconnection Reference Model (SDSI-RM) incorporates the conventions of the OSIRM to provide a framework within which a complete set of space data handling services can be defined. The use of the SDSI-RM is illustrated through its application to data handling services and protocols that have been defined by, or are under consideration by, the Consultative Committee for Space Data Systems (CCSDS).

  18. A reference model for space data system interconnection services

    NASA Technical Reports Server (NTRS)

    Pietras, John; Theis, Gerhard

    1993-01-01

    The widespread adoption of standard packet-based data communication protocols and services for spaceflight missions provides the foundation for other standard space data handling services. These space data handling services can be defined as increasingly sophisticated processing of data or information received from lower-level services, using a layering approach made famous in the International Organization for Standardization (ISO) Open System Interconnection Reference Model (OSI-RM). The Space Data System Interconnection Reference Model (SDSI-RM) incorporates the conventions of the OSIRM to provide a framework within which a complete set of space data handling services can be defined. The use of the SDSI-RM is illustrated through its application to data handling services and protocols that have been defined by, or are under consideration by, the Consultative Committee for Space Data Systems (CCSDS).

  19. Issues and Methods for Standard-Setting.

    ERIC Educational Resources Information Center

    Hambleton, Ronald K.; And Others

    Issues involved in standard setting along with methods for standard setting are reviewed, with specific reference to their relevance for criterion referenced testing. Definitions are given of continuum and state models, and traditional and normative standard setting procedures. Since continuum models are considered more appropriate for criterion…

  20. Middle Atmosphere Program. Handbook for MAP. Volume 31: Reference models of trace species for the COSPAR international reference atmosphere

    NASA Technical Reports Server (NTRS)

    Keating, G. M. (Editor)

    1989-01-01

    A set of preliminary reference atmosphere models of significant trace species which play important roles in controlling the chemistry, radiation budget, and circulation patterns of the atmosphere were produced. These models of trace species distributions are considered to be reference models rather than standard models; thus, it was not crucial that they be correct in an absolute sense. These reference models can serve as a means of comparison between individual observations, as a first guess in inversion algorithms, and as an approximate representation of observations for comparison to theoretical calculations.

  1. 24 CFR 200.926b - Model codes.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 2 2010-04-01 2010-04-01 false Model codes. 200.926b Section 200... DEVELOPMENT GENERAL INTRODUCTION TO FHA PROGRAMS Minimum Property Standards § 200.926b Model codes. (a) Incorporation by reference. The following model code publications are incorporated by reference in accordance...

  2. Particle size distributions by transmission electron microscopy: an interlaboratory comparison case study

    PubMed Central

    Rice, Stephen B; Chan, Christopher; Brown, Scott C; Eschbach, Peter; Han, Li; Ensor, David S; Stefaniak, Aleksandr B; Bonevich, John; Vladár, András E; Hight Walker, Angela R; Zheng, Jiwen; Starnes, Catherine; Stromberg, Arnold; Ye, Jia; Grulke, Eric A

    2015-01-01

    This paper reports an interlaboratory comparison that evaluated a protocol for measuring and analysing the particle size distribution of discrete, metallic, spheroidal nanoparticles using transmission electron microscopy (TEM). The study was focused on automated image capture and automated particle analysis. NIST RM8012 gold nanoparticles (30 nm nominal diameter) were measured for area-equivalent diameter distributions by eight laboratories. Statistical analysis was used to (1) assess the data quality without using size distribution reference models, (2) determine reference model parameters for different size distribution reference models and non-linear regression fitting methods and (3) assess the measurement uncertainty of a size distribution parameter by using its coefficient of variation. The interlaboratory area-equivalent diameter mean, 27.6 nm ± 2.4 nm (computed based on a normal distribution), was quite similar to the area-equivalent diameter, 27.6 nm, assigned to NIST RM8012. The lognormal reference model was the preferred choice for these particle size distributions as, for all laboratories, its parameters had lower relative standard errors (RSEs) than the other size distribution reference models tested (normal, Weibull and Rosin–Rammler–Bennett). The RSEs for the fitted standard deviations were two orders of magnitude higher than those for the fitted means, suggesting that most of the parameter estimate errors were associated with estimating the breadth of the distributions. The coefficients of variation for the interlaboratory statistics also confirmed the lognormal reference model as the preferred choice. From quasi-linear plots, the typical range for good fits between the model and cumulative number-based distributions was 1.9 fitted standard deviations less than the mean to 2.3 fitted standard deviations above the mean. Automated image capture, automated particle analysis and statistical evaluation of the data and fitting coefficients provide a framework for assessing nanoparticle size distributions using TEM for image acquisition. PMID:26361398

  3. Incorporating geographical factors with artificial neural networks to predict reference values of erythrocyte sedimentation rate

    PubMed Central

    2013-01-01

    Background The measurement of the Erythrocyte Sedimentation Rate (ESR) value is a standard procedure performed during a typical blood test. In order to formulate a unified standard of establishing reference ESR values, this paper presents a novel prediction model in which local normal ESR values and corresponding geographical factors are used to predict reference ESR values using multi-layer feed-forward artificial neural networks (ANN). Methods and findings Local normal ESR values were obtained from hospital data, while geographical factors that include altitude, sunshine hours, relative humidity, temperature and precipitation were obtained from the National Geographical Data Information Centre in China. The results show that predicted values are statistically in agreement with measured values. Model results exhibit significant agreement between training data and test data. Consequently, the model is used to predict the unseen local reference ESR values. Conclusions Reference ESR values can be established with geographical factors by using artificial intelligence techniques. ANN is an effective method for simulating and predicting reference ESR values because of its ability to model nonlinear and complex relationships. PMID:23497145

  4. Incorporating geographical factors with artificial neural networks to predict reference values of erythrocyte sedimentation rate.

    PubMed

    Yang, Qingsheng; Mwenda, Kevin M; Ge, Miao

    2013-03-12

    The measurement of the Erythrocyte Sedimentation Rate (ESR) value is a standard procedure performed during a typical blood test. In order to formulate a unified standard of establishing reference ESR values, this paper presents a novel prediction model in which local normal ESR values and corresponding geographical factors are used to predict reference ESR values using multi-layer feed-forward artificial neural networks (ANN). Local normal ESR values were obtained from hospital data, while geographical factors that include altitude, sunshine hours, relative humidity, temperature and precipitation were obtained from the National Geographical Data Information Centre in China.The results show that predicted values are statistically in agreement with measured values. Model results exhibit significant agreement between training data and test data. Consequently, the model is used to predict the unseen local reference ESR values. Reference ESR values can be established with geographical factors by using artificial intelligence techniques. ANN is an effective method for simulating and predicting reference ESR values because of its ability to model nonlinear and complex relationships.

  5. H∞ output tracking control of discrete-time nonlinear systems via standard neural network models.

    PubMed

    Liu, Meiqin; Zhang, Senlin; Chen, Haiyang; Sheng, Weihua

    2014-10-01

    This brief proposes an output tracking control for a class of discrete-time nonlinear systems with disturbances. A standard neural network model is used to represent discrete-time nonlinear systems whose nonlinearity satisfies the sector conditions. H∞ control performance for the closed-loop system including the standard neural network model, the reference model, and state feedback controller is analyzed using Lyapunov-Krasovskii stability theorem and linear matrix inequality (LMI) approach. The H∞ controller, of which the parameters are obtained by solving LMIs, guarantees that the output of the closed-loop system closely tracks the output of a given reference model well, and reduces the influence of disturbances on the tracking error. Three numerical examples are provided to show the effectiveness of the proposed H∞ output tracking design approach.

  6. More is still not better: testing the perturbation model of temporal reference memory across different modalities and tasks.

    PubMed

    Ogden, Ruth S; Jones, Luke A

    2009-05-01

    The ability of the perturbation model (Jones & Wearden, 2003) to account for reference memory function in a visual temporal generalization task and auditory and visual reproduction tasks was examined. In all tasks the number of presentations of the standard was manipulated (1, 3, or 5), and its effect on performance was compared. In visual temporal generalization the number of presentations of the standard did not affect the number of times the standard was correctly identified, nor did it affect the overall temporal generalization gradient. In auditory reproduction there was no effect of the number of times the standard was presented on mean reproductions. In visual reproduction mean reproductions were shorter when the standard was only presented once; however, this effect was reduced when a visual cue was provided before the first presentation of the standard. Whilst the results of all experiments are best accounted for by the perturbation model there appears to be some attentional benefit to multiple presentations of the standard in visual reproduction.

  7. Proposed Reference Spectral Irradiance Standards to Improve Photovoltaic Concentrating System Design and Performance Evaluation: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Myers, D. R.; Emery, K. E.; Gueymard, C.

    2002-05-01

    This conference paper describes the American Society for Testing and Materials (ASTM), the International Electrotechnical Commission (IEC), and the International Standards Organization (ISO) standard solar terrestrial spectra (ASTM G-159, IEC-904-3, ISO 9845-1) provide standard spectra for photovoltaic performance applications. Modern terrestrial spectral radiation models and knowledge of atmospheric physics are applied to develop suggested revisions to update the reference spectra. We use a moderately complex radiative transfer model (SMARTS2) to produce the revised spectra. SMARTS2 has been validated against the complex MODTRAN radiative transfer code and spectral measurements. The model is proposed as an adjunct standard to reproduce the referencemore » spectra. The proposed spectra represent typical clear sky spectral conditions associated with sites representing reasonable photovoltaic energy production and weathering and durability climates. The proposed spectra are under consideration by ASTM.« less

  8. The role of ion mobility spectrometry-mass spectrometry in the analysis of protein reference standards.

    PubMed

    Pritchard, Caroline; O'Connor, Gavin; Ashcroft, Alison E

    2013-08-06

    To achieve comparability of measurement results of protein amount of substance content between clinical laboratories, suitable reference materials are required. The impact on measurement comparability of potential differences in the tertiary and quaternary structure of protein reference standards is as yet not well understood. With the use of human growth hormone as a model protein, the potential of ion mobility spectrometry-mass spectrometry as a tool to assess differences in the structure of protein reference materials and their interactions with antibodies has been investigated here.

  9. Absolute Salinity, ''Density Salinity'' and the Reference-Composition Salinity Scale: present and future use in the seawater standard TEOS-10

    NASA Astrophysics Data System (ADS)

    Wright, D. G.; Pawlowicz, R.; McDougall, T. J.; Feistel, R.; Marion, G. M.

    2011-01-01

    Salinity plays a key role in the determination of the thermodynamic properties of seawater and the new TEOS-101 standard provides a consistent and effective approach to dealing with relationships between salinity and these thermodynamic properties. However, there are a number of practical issues that arise in the application of TEOS-10, both in terms of accuracy and scope, including its use in the reduction of field data and in numerical models. First, in the TEOS-10 formulation for IAPSO Standard Seawater, the Gibbs function takes the Reference Salinity as its salinity argument, denoted SR, which provides a measure of the mass fraction of dissolved material in solution based on the Reference Composition approximation for Standard Seawater. We discuss uncertainties in both the Reference Composition and the Reference-Composition Salinity Scale on which Reference Salinity is reported. The Reference Composition provides a much-needed fixed benchmark but modified reference states will inevitably be required to improve the representation of Standard Seawater for some studies. However, the Reference-Composition Salinity Scale should remain unaltered to provide a stable representation of salinity for use with the TEOS-10 Gibbs function and in climate change detection studies. Second, when composition anomalies are present in seawater, no single salinity variable can fully represent the influence of dissolved material on the thermodynamic properties of seawater. We consider three distinct representations of salinity that have been used in previous studies and discuss the connections and distinctions between them. One of these variables provides the most accurate representation of density possible as well as improvements over Reference Salinity for the determination of other thermodynamic properties. It is referred to as "Density Salinity" and is represented by the symbol SAdens; it stands out as the most appropriate representation of salinity for use in dynamical physical oceanography. The other two salinity variables provide alternative measures of the mass fraction of dissolved material in seawater. "Solution Salinity", denoted SAsoln, is the most obvious extension of Reference Salinity to allow for composition anomalies; it provides a direct estimate of the mass fraction of dissolved material in solution. "Added-Mass Salinity", denoted SAadd, is motivated by a method used to report laboratory experiments; it represents the component of dissolved material added to Standard Seawater in terms of the mass of material before it enters solution. We also discuss a constructed conservative variable referred to as "Preformed Salinity", denoted S∗, which will be useful in process-oriented numerical modelling studies. Finally, a conceptual framework for the incorporation of composition anomalies in numerical models is presented that builds from studies in which composition anomalies are simply ignored up to studies in which the influences of composition anomalies are accounted for using the results of biogeochemical models. 1TEOS-10: international Thermodynamic Equation of Seawater 2010, http://www.teos-10.org/.

  10. Absolute Salinity, "Density Salinity" and the Reference-Composition Salinity Scale: present and future use in the seawater standard TEOS-10

    NASA Astrophysics Data System (ADS)

    Wright, D. G.; Pawlowicz, R.; McDougall, T. J.; Feistel, R.; Marion, G. M.

    2010-08-01

    Salinity plays a key role in the determination of the thermodynamic properties of seawater and the new TEOS-101 standard provides a consistent and effective approach to dealing with relationships between salinity and these thermodynamic properties. However, there are a number of practical issues that arise in the application of TEOS-10, both in terms of accuracy and scope, including its use in the reduction of field data and in numerical models. First, in the TEOS-10 formulation for IAPSO Standard Seawater, the Gibbs function takes the Reference Salinity as its salinity argument, denoted SR, which provides a measure of the mass fraction of dissolved material in solution based on the Reference Composition approximation for Standard Seawater. We discuss uncertainties in both the Reference Composition and the Reference-Composition Salinity Scale on which Reference Salinity is reported. The Reference Composition provides a much-needed fixed benchmark but modified reference states will inevitably be required to improve the representation of Standard Seawater for some studies. The Reference-Composition Salinity Scale should remain unaltered to provide a stable representation of salinity for use with the TEOS-10 Gibbs function and in climate change detection studies. Second, when composition anomalies are present in seawater, no single salinity variable can fully represent the influence of dissolved material on the thermodynamic properties of seawater. We consider three distinct representations of salinity that have been used in previous studies and discuss the connections and distinctions between them. One of these variables provides the most accurate representation of density possible as well as improvements over Reference Salinity for the determination of other thermodynamic properties. It is referred to as "Density Salinity" and is represented by the symbol SAdens; it stands out as the most appropriate representation of salinity for use in dynamical physical oceanography. The other two salinity variables provide alternative measures of the mass fraction of dissolved material in seawater. "Solution Salinity", denoted SAsoln, is the most obvious extension of Reference Salinity to allow for composition anomalies; it provides a direct estimate of the mass fraction of dissolved material in solution. "Added-Mass Salinity", denoted SAadd, is motivated by a method used to report laboratory experiments; it represents the component of dissolved material added to Standard Seawater in terms of the mass of material before it enters solution. We also discuss a constructed conservative variable referred to as "Preformed Salinity", denoted S*, which will be useful in process-oriented numerical modelling studies. Finally, a conceptual framework for the incorporation of composition anomalies in numerical models is presented that builds from studies in which composition anomalies are simply ignored up to studies in which the influences of composition anomalies are accounted for using the results of biogeochemical models. 1TEOS-10: international thermodynamic equation of seawater 2010, http://www.teos-10.org.

  11. Effects of tectonic plate deformation on the geodetic reference frame of Mexico

    NASA Astrophysics Data System (ADS)

    Gonzalez Franco, G. A.; Avalos, D.; Esquivel, R.

    2013-05-01

    Positioning for geodetic applications is commonly determined at one observation epoch, but tectonic drift and tectonic deformation cause the coordinates to be different for any other epoch. Finding the right coordinates at a different epoch from that of the observation time is necessary in Mexico in order to comply the official reference frame, which requires all coordinates to be referred to the standard epoch 2010.0. Available models of horizontal movement in rigid tectonic plates are used to calculate the displacement of coordinates; however for a portion of Mexico these models fail because of miss-modeled regional deformation, decreasing the quality of users' data transformed to the standard epoch. In this work we present the progress achieved in measuring actual horizontal motion towards an improved modeling of horizontal displacements for some regions. Miss-modeled velocities found are as big as 23mm/a, affecting significantly applications like cadastral and geodetic control. Data from a large set of GNSS permanent stations in Mexico is being analyzed to produce the preliminary model of horizontal crustal movement that will be used to minimize distortions of the reference frame.

  12. NASA/NBS (National Aeronautics and Space Administration/National Bureau of Standards) standard reference model for telerobot control system architecture (NASREM)

    NASA Technical Reports Server (NTRS)

    Albus, James S.; Mccain, Harry G.; Lumia, Ronald

    1989-01-01

    The document describes the NASA Standard Reference Model (NASREM) Architecture for the Space Station Telerobot Control System. It defines the functional requirements and high level specifications of the control system for the NASA space Station document for the functional specification, and a guideline for the development of the control system architecture, of the 10C Flight Telerobot Servicer. The NASREM telerobot control system architecture defines a set of standard modules and interfaces which facilitates software design, development, validation, and test, and make possible the integration of telerobotics software from a wide variety of sources. Standard interfaces also provide the software hooks necessary to incrementally upgrade future Flight Telerobot Systems as new capabilities develop in computer science, robotics, and autonomous system control.

  13. The CMMI Product Suite and International Standards

    DTIC Science & Technology

    2006-07-01

    standards: “2.3 Reference Documents 2.3.1 Applicable ISO /IEC documents, including ISO /IEC 12207 and ISO /IEC 15504.” “3.1 Development User Requirements...related international standards such as ISO 9001:2000, 12207 , 15288 © 2006 by Carnegie Mellon University Page 12 Key Supplements Needed...the Measurement Framework in ISO /IEC 15504; and • the Process Reference Model included in ISO /IEC 12207 . A possible approach has been developed for

  14. An Optimal Control Modification to Model-Reference Adaptive Control for Fast Adaptation

    NASA Technical Reports Server (NTRS)

    Nguyen, Nhan T.; Krishnakumar, Kalmanje; Boskovic, Jovan

    2008-01-01

    This paper presents a method that can achieve fast adaptation for a class of model-reference adaptive control. It is well-known that standard model-reference adaptive control exhibits high-gain control behaviors when a large adaptive gain is used to achieve fast adaptation in order to reduce tracking error rapidly. High gain control creates high-frequency oscillations that can excite unmodeled dynamics and can lead to instability. The fast adaptation approach is based on the minimization of the squares of the tracking error, which is formulated as an optimal control problem. The necessary condition of optimality is used to derive an adaptive law using the gradient method. This adaptive law is shown to result in uniform boundedness of the tracking error by means of the Lyapunov s direct method. Furthermore, this adaptive law allows a large adaptive gain to be used without causing undesired high-gain control effects. The method is shown to be more robust than standard model-reference adaptive control. Simulations demonstrate the effectiveness of the proposed method.

  15. Proposed Clinical Decision Rules to Diagnose Acute Rhinosinusitis Among Adults in Primary Care.

    PubMed

    Ebell, Mark H; Hansen, Jens Georg

    2017-07-01

    To reduce inappropriate antibiotic prescribing, we sought to develop a clinical decision rule for the diagnosis of acute rhinosinusitis and acute bacterial rhinosinusitis. Multivariate analysis and classification and regression tree (CART) analysis were used to develop clinical decision rules for the diagnosis of acute rhinosinusitis, defined using 3 different reference standards (purulent antral puncture fluid or abnormal finding on a computed tomographic (CT) scan; for acute bacterial rhinosinusitis, we used a positive bacterial culture of antral fluid). Signs, symptoms, C-reactive protein (CRP), and reference standard tests were prospectively recorded in 175 Danish patients aged 18 to 65 years seeking care for suspected acute rhinosinusitis. For each reference standard, we developed 2 clinical decision rules: a point score based on a logistic regression model and an algorithm based on a CART model. We identified low-, moderate-, and high-risk groups for acute rhinosinusitis or acute bacterial rhinosinusitis for each clinical decision rule. The point scores each had between 5 and 6 predictors, and an area under the receiver operating characteristic curve (AUROCC) between 0.721 and 0.767. For positive bacterial culture as the reference standard, low-, moderate-, and high-risk groups had a 16%, 49%, and 73% likelihood of acute bacterial rhinosinusitis, respectively. CART models had an AUROCC ranging from 0.783 to 0.827. For positive bacterial culture as the reference standard, low-, moderate-, and high-risk groups had a likelihood of acute bacterial rhinosinusitis of 6%, 31%, and 59% respectively. We have developed a series of clinical decision rules integrating signs, symptoms, and CRP to diagnose acute rhinosinusitis and acute bacterial rhinosinusitis with good accuracy. They now require prospective validation and an assessment of their effect on clinical and process outcomes. © 2017 Annals of Family Medicine, Inc.

  16. How do reference montage and electrodes setup affect the measured scalp EEG potentials?

    NASA Astrophysics Data System (ADS)

    Hu, Shiang; Lai, Yongxiu; Valdes-Sosa, Pedro A.; Bringas-Vega, Maria L.; Yao, Dezhong

    2018-04-01

    Objective. Human scalp electroencephalogram (EEG) is widely applied in cognitive neuroscience and clinical studies due to its non-invasiveness and ultra-high time resolution. However, the representativeness of the measured EEG potentials for the underneath neural activities is still a problem under debate. This study aims to investigate systematically how both reference montage and electrodes setup affect the accuracy of EEG potentials. Approach. First, the standard EEG potentials are generated by the forward calculation with a single dipole in the neural source space, for eleven channel numbers (10, 16, 21, 32, 64, 85, 96, 128, 129, 257, 335). Here, the reference is the ideal infinity implicitly determined by forward theory. Then, the standard EEG potentials are transformed to recordings with different references including five mono-polar references (Left earlobe, Fz, Pz, Oz, Cz), and three re-references (linked mastoids (LM), average reference (AR) and reference electrode standardization technique (REST)). Finally, the relative errors between the standard EEG potentials and the transformed ones are evaluated in terms of channel number, scalp regions, electrodes layout, dipole source position and orientation, as well as sensor noise and head model. Main results. Mono-polar reference recordings are usually of large distortions; thus, a re-reference after online mono-polar recording should be adopted in general to mitigate this effect. Among the three re-references, REST is generally superior to AR for all factors compared, and LM performs worst. REST is insensitive to head model perturbation. AR is subject to electrodes coverage and dipole orientation but no close relation with channel number. Significance. These results indicate that REST would be the first choice of re-reference and AR may be an alternative option for high level sensor noise case. Our findings may provide the helpful suggestions on how to obtain the EEG potentials as accurately as possible for cognitive neuroscientists and clinicians.

  17. An E-Learning Framework for Assessment (FREMA)

    ERIC Educational Resources Information Center

    Wills, Gary B.; Bailey, Christopher P.; Davis, Hugh C.; Gilbert, Lester; Howard, Yvonne; Jeyes, Steve; Millard, David E.; Price, Joseph; Sclater, Niall; Sherratt, Robert; Tulloch, Iain; Young, Rowin

    2009-01-01

    This article reports on the e-Framework Reference Model for Assessment (FREMA) project that aimed at creating a reference model for the assessment domain: a guide to what resources (standards, projects, people, organisations, software, services and use cases) exist for the domain, aimed at helping strategists understand the state of e-learning…

  18. Development of Automated Procedures to Generate Reference Building Models for ASHRAE Standard 90.1 and India’s Building Energy Code and Implementation in OpenStudio

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parker, Andrew; Haves, Philip; Jegi, Subhash

    This paper describes a software system for automatically generating a reference (baseline) building energy model from the proposed (as-designed) building energy model. This system is built using the OpenStudio Software Development Kit (SDK) and is designed to operate on building energy models in the OpenStudio file format.

  19. A proposed application programming interface for a physical volume repository

    NASA Technical Reports Server (NTRS)

    Jones, Merritt; Williams, Joel; Wrenn, Richard

    1996-01-01

    The IEEE Storage System Standards Working Group (SSSWG) has developed the Reference Model for Open Storage Systems Interconnection, Mass Storage System Reference Model Version 5. This document, provides the framework for a series of standards for application and user interfaces to open storage systems. More recently, the SSSWG has been developing Application Programming Interfaces (APIs) for the individual components defined by the model. The API for the Physical Volume Repository is the most fully developed, but work is being done on APIs for the Physical Volume Library and for the Mover also. The SSSWG meets every other month, and meetings are open to all interested parties. The Physical Volume Repository (PVR) is responsible for managing the storage of removable media cartridges and for mounting and dismounting these cartridges onto drives. This document describes a model which defines a Physical Volume Repository, and gives a brief summary of the Application Programming Interface (API) which the IEEE Storage Systems Standards Working Group (SSSWG) is proposing as the standard interface for the PVR.

  20. The NASA Marshall Space Flight Center Earth Global Reference Atmospheric Model-2010 Version

    NASA Technical Reports Server (NTRS)

    Leslie, F. W.; Justus, C. G.

    2011-01-01

    Reference or standard atmospheric models have long been used for design and mission planning of various aerospace systems. The NASA Marshall Space Flight Center Global Reference Atmospheric Model was developed in response to the need for a design reference atmosphere that provides complete global geographical variability and complete altitude coverage (surface to orbital altitudes), as well as complete seasonal and monthly variability of the thermodynamic variables and wind components. In addition to providing the geographical, height, and monthly variation of the mean atmospheric state, it includes the ability to simulate spatial and temporal perturbations.

  1. Virtual Reference Transcript Analysis: A Few Models.

    ERIC Educational Resources Information Center

    Smyth, Joanne

    2003-01-01

    Describes the introduction of virtual, or digital, reference service at the University of New Brunswick libraries. Highlights include analyzing transcripts from LIVE (Library Information in a Virtual Environment); reference question types; ACRL (Association of College and Research Libraries) information literacy competency standards; and the Big 6…

  2. 230Th-234U Model-Ages of Some Uranium Standard Reference Materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Williams, R W; Gaffney, A M; Kristo, M J

    The 'age' of a sample of uranium is an important aspect of a nuclear forensic investigation and of the attribution of the material to its source. To the extent that the sample obeys the standard rules of radiochronometry, then the production ages of even very recent material can be determined using the {sup 230}Th-{sup 234}U chronometer. These standard rules may be summarized as (a) the daughter/parent ratio at time=zero must be known, and (b) there has been no daughter/parent fractionation since production. For most samples of uranium, the 'ages' determined using this chronometer are semantically 'model-ages' because (a) some assumptionmore » of the initial {sup 230}Th content in the sample is required and (b) closed-system behavior is assumed. The uranium standard reference materials originally prepared and distributed by the former US National Bureau of Standards and now distributed by New Brunswick Laboratory as certified reference materials (NBS SRM = NBL CRM) are good candidates for samples where both rules are met. The U isotopic standards have known purification and production dates, and closed-system behavior in the solid form (U{sub 3}O{sub 8}) may be assumed with confidence. We present here {sup 230}Th-{sup 234}U model-ages for several of these standards, determined by isotope dilution mass spectrometry using a multicollector ICP-MS, and compare these ages with their known production history.« less

  3. ACR/NEMA Digital Image Interface Standard (An Illustrated Protocol Overview)

    NASA Astrophysics Data System (ADS)

    Lawrence, G. Robert

    1985-09-01

    The American College of Radiologists (ACR) and the National Electrical Manufacturers Association (NEMA) have sponsored a joint standards committee mandated to develop a universal interface standard for the transfer of radiology images among a variety of PACS imaging devicesl. The resulting standard interface conforms to the ISO/OSI standard reference model for network protocol layering. The standard interface specifies the lower layers of the reference model (Physical, Data Link, Transport and Session) and implies a requirement of the Network Layer should a requirement for a network exist. The message content has been considered and a flexible message and image format specified. The following Imaging Equipment modalities are supported by the standard interface... CT Computed Tomograpy DS Digital Subtraction NM Nuclear Medicine US Ultrasound MR Magnetic Resonance DR Digital Radiology The following data types are standardized over the transmission interface media.... IMAGE DATA DIGITIZED VOICE HEADER DATA RAW DATA TEXT REPORTS GRAPHICS OTHERS This paper consists of text supporting the illustrated protocol data flow. Each layer will be individually treated. Particular emphasis will be given to the Data Link layer (Frames) and the Transport layer (Packets). The discussion utilizes a finite state sequential machine model for the protocol layers.

  4. Application of the 226Ra– 230Th– 234U and 227Ac– 231Pa– 235U radiochronometers to uranium certified reference materials

    DOE PAGES

    Rolison, John M.; Treinen, Kerri C.; McHugh, Kelly C.; ...

    2017-11-06

    Uranium certified reference materials (CRM) issued by New Brunswick Laboratory were subjected to dating using four independent uranium-series radiochronometers. In all cases, there was acceptable agreement between the model ages calculated using the 231Pa– 235U, 230Th– 234U, 227Ac– 235U or 226Ra– 234U radiochronometers and either the certified 230Th– 234U model date (CRM 125-A and CRM U630), or the known purification date (CRM U050 and CRM U100). Finally, the agreement between the four independent radiochronometers establishes these uranium certified reference materials as ideal informal standards for validating dating techniques utilized in nuclear forensic investigations in the absence of standards with certifiedmore » model ages for multiple radiochronometers.« less

  5. Application of the 226Ra– 230Th– 234U and 227Ac– 231Pa– 235U radiochronometers to uranium certified reference materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rolison, John M.; Treinen, Kerri C.; McHugh, Kelly C.

    Uranium certified reference materials (CRM) issued by New Brunswick Laboratory were subjected to dating using four independent uranium-series radiochronometers. In all cases, there was acceptable agreement between the model ages calculated using the 231Pa– 235U, 230Th– 234U, 227Ac– 235U or 226Ra– 234U radiochronometers and either the certified 230Th– 234U model date (CRM 125-A and CRM U630), or the known purification date (CRM U050 and CRM U100). Finally, the agreement between the four independent radiochronometers establishes these uranium certified reference materials as ideal informal standards for validating dating techniques utilized in nuclear forensic investigations in the absence of standards with certifiedmore » model ages for multiple radiochronometers.« less

  6. Implementing parallel spreadsheet models for health policy decisions: The impact of unintentional errors on model projections

    PubMed Central

    Bailey, Stephanie L.; Bono, Rose S.; Nash, Denis; Kimmel, April D.

    2018-01-01

    Background Spreadsheet software is increasingly used to implement systems science models informing health policy decisions, both in academia and in practice where technical capacity may be limited. However, spreadsheet models are prone to unintentional errors that may not always be identified using standard error-checking techniques. Our objective was to illustrate, through a methodologic case study analysis, the impact of unintentional errors on model projections by implementing parallel model versions. Methods We leveraged a real-world need to revise an existing spreadsheet model designed to inform HIV policy. We developed three parallel versions of a previously validated spreadsheet-based model; versions differed by the spreadsheet cell-referencing approach (named single cells; column/row references; named matrices). For each version, we implemented three model revisions (re-entry into care; guideline-concordant treatment initiation; immediate treatment initiation). After standard error-checking, we identified unintentional errors by comparing model output across the three versions. Concordant model output across all versions was considered error-free. We calculated the impact of unintentional errors as the percentage difference in model projections between model versions with and without unintentional errors, using +/-5% difference to define a material error. Results We identified 58 original and 4,331 propagated unintentional errors across all model versions and revisions. Over 40% (24/58) of original unintentional errors occurred in the column/row reference model version; most (23/24) were due to incorrect cell references. Overall, >20% of model spreadsheet cells had material unintentional errors. When examining error impact along the HIV care continuum, the percentage difference between versions with and without unintentional errors ranged from +3% to +16% (named single cells), +26% to +76% (column/row reference), and 0% (named matrices). Conclusions Standard error-checking techniques may not identify all errors in spreadsheet-based models. Comparing parallel model versions can aid in identifying unintentional errors and promoting reliable model projections, particularly when resources are limited. PMID:29570737

  7. Implementing parallel spreadsheet models for health policy decisions: The impact of unintentional errors on model projections.

    PubMed

    Bailey, Stephanie L; Bono, Rose S; Nash, Denis; Kimmel, April D

    2018-01-01

    Spreadsheet software is increasingly used to implement systems science models informing health policy decisions, both in academia and in practice where technical capacity may be limited. However, spreadsheet models are prone to unintentional errors that may not always be identified using standard error-checking techniques. Our objective was to illustrate, through a methodologic case study analysis, the impact of unintentional errors on model projections by implementing parallel model versions. We leveraged a real-world need to revise an existing spreadsheet model designed to inform HIV policy. We developed three parallel versions of a previously validated spreadsheet-based model; versions differed by the spreadsheet cell-referencing approach (named single cells; column/row references; named matrices). For each version, we implemented three model revisions (re-entry into care; guideline-concordant treatment initiation; immediate treatment initiation). After standard error-checking, we identified unintentional errors by comparing model output across the three versions. Concordant model output across all versions was considered error-free. We calculated the impact of unintentional errors as the percentage difference in model projections between model versions with and without unintentional errors, using +/-5% difference to define a material error. We identified 58 original and 4,331 propagated unintentional errors across all model versions and revisions. Over 40% (24/58) of original unintentional errors occurred in the column/row reference model version; most (23/24) were due to incorrect cell references. Overall, >20% of model spreadsheet cells had material unintentional errors. When examining error impact along the HIV care continuum, the percentage difference between versions with and without unintentional errors ranged from +3% to +16% (named single cells), +26% to +76% (column/row reference), and 0% (named matrices). Standard error-checking techniques may not identify all errors in spreadsheet-based models. Comparing parallel model versions can aid in identifying unintentional errors and promoting reliable model projections, particularly when resources are limited.

  8. Tibiofemoral wear in standard and non-standard squat: implication for total knee arthroplasty.

    PubMed

    Fekete, Gusztáv; Sun, Dong; Gu, Yaodong; Neis, Patric Daniel; Ferreira, Ney Francisco; Innocenti, Bernardo; Csizmadia, Béla M

    2017-01-01

    Due to the more resilient biomaterials, problems related to wear in total knee replacements (TKRs) have decreased but not disappeared. In the design-related factors, wear is still the second most important mechanical factor that limits the lifetime of TKRs and it is also highly influenced by the local kinematics of the knee. During wear experiments, constant load and slide-roll ratio is frequently applied in tribo-tests beside other important parameters. Nevertheless, numerous studies demonstrated that constant slide-roll ratio is not accurate approach if TKR wear is modelled, while instead of a constant load, a flexion-angle dependent tibiofemoral force should be involved into the wear model to obtain realistic results. A new analytical wear model, based upon Archard's law, is introduced, which can determine the effect of the tibiofemoral force and the varying slide-roll on wear between the tibiofemoral connection under standard and non-standard squat movement. The calculated total wear with constant slide-roll during standard squat was 5.5 times higher compared to the reference value, while if total wear includes varying slide-roll during standard squat, the calculated wear was approximately 6.25 times higher. With regard to non-standard squat, total wear with constant slide-roll during standard squat was 4.16 times higher than the reference value. If total wear included varying slide-roll, the calculated wear was approximately 4.75 times higher. It was demonstrated that the augmented force parameter solely caused 65% higher wear volume while the slide-roll ratio itself increased wear volume by 15% higher compared to the reference value. These results state that the force component has the major effect on wear propagation while non-standard squat should be proposed for TKR patients as rehabilitation exercise.

  9. Tibiofemoral wear in standard and non-standard squat: implication for total knee arthroplasty

    PubMed Central

    Sun, Dong; Gu, Yaodong; Neis, Patric Daniel; Ferreira, Ney Francisco; Innocenti, Bernardo; Csizmadia, Béla M.

    2017-01-01

    Summary Introduction Due to the more resilient biomaterials, problems related to wear in total knee replacements (TKRs) have decreased but not disappeared. In the design-related factors, wear is still the second most important mechanical factor that limits the lifetime of TKRs and it is also highly influenced by the local kinematics of the knee. During wear experiments, constant load and slide-roll ratio is frequently applied in tribo-tests beside other important parameters. Nevertheless, numerous studies demonstrated that constant slide-roll ratio is not accurate approach if TKR wear is modelled, while instead of a constant load, a flexion-angle dependent tibiofemoral force should be involved into the wear model to obtain realistic results. Methods A new analytical wear model, based upon Archard’s law, is introduced, which can determine the effect of the tibiofemoral force and the varying slide-roll on wear between the tibiofemoral connection under standard and non-standard squat movement. Results The calculated total wear with constant slide-roll during standard squat was 5.5 times higher compared to the reference value, while if total wear includes varying slide-roll during standard squat, the calculated wear was approximately 6.25 times higher. With regard to non-standard squat, total wear with constant slide-roll during standard squat was 4.16 times higher than the reference value. If total wear included varying slide-roll, the calculated wear was approximately 4.75 times higher. Conclusions It was demonstrated that the augmented force parameter solely caused 65% higher wear volume while the slide-roll ratio itself increased wear volume by 15% higher compared to the reference value. These results state that the force component has the major effect on wear propagation while non-standard squat should be proposed for TKR patients as rehabilitation exercise. PMID:29721453

  10. Optimal weighted combinatorial forecasting model of QT dispersion of ECGs in Chinese adults.

    PubMed

    Wen, Zhang; Miao, Ge; Xinlei, Liu; Minyi, Cen

    2016-07-01

    This study aims to provide a scientific basis for unifying the reference value standard of QT dispersion of ECGs in Chinese adults. Three predictive models including regression model, principal component model, and artificial neural network model are combined to establish the optimal weighted combination model. The optimal weighted combination model and single model are verified and compared. Optimal weighted combinatorial model can reduce predicting risk of single model and improve the predicting precision. The reference value of geographical distribution of Chinese adults' QT dispersion was precisely made by using kriging methods. When geographical factors of a particular area are obtained, the reference value of QT dispersion of Chinese adults in this area can be estimated by using optimal weighted combinatorial model and reference value of the QT dispersion of Chinese adults anywhere in China can be obtained by using geographical distribution figure as well.

  11. The NASA MSFC Earth Global Reference Atmospheric Model-2007 Version

    NASA Technical Reports Server (NTRS)

    Leslie, F.W.; Justus, C.G.

    2008-01-01

    Reference or standard atmospheric models have long been used for design and mission planning of various aerospace systems. The NASA/Marshall Space Flight Center (MSFC) Global Reference Atmospheric Model (GRAM) was developed in response to the need for a design reference atmosphere that provides complete global geographical variability, and complete altitude coverage (surface to orbital altitudes) as well as complete seasonal and monthly variability of the thermodynamic variables and wind components. A unique feature of GRAM is that, addition to providing the geographical, height, and monthly variation of the mean atmospheric state, it includes the ability to simulate spatial and temporal perturbations in these atmospheric parameters (e.g. fluctuations due to turbulence and other atmospheric perturbation phenomena). A summary comparing GRAM features to characteristics and features of other reference or standard atmospheric models, can be found Guide to Reference and Standard Atmosphere Models. The original GRAM has undergone a series of improvements over the years with recent additions and changes. The software program is called Earth-GRAM2007 to distinguish it from similar programs for other bodies (e.g. Mars, Venus, Neptune, and Titan). However, in order to make this Technical Memorandum (TM) more readable, the software will be referred to simply as GRAM07 or GRAM unless additional clarity is needed. Section 1 provides an overview of the basic features of GRAM07 including the newly added features. Section 2 provides a more detailed description of GRAM07 and how the model output generated. Section 3 presents sample results. Appendices A and B describe the Global Upper Air Climatic Atlas (GUACA) data and the Global Gridded Air Statistics (GGUAS) database. Appendix C provides instructions for compiling and running GRAM07. Appendix D gives a description of the required NAMELIST format input. Appendix E gives sample output. Appendix F provides a list of available parameters to enable the user to generate special output. Appendix G gives an example and guidance on incorporating GRAM07 as a subroutine in other programs such as trajectory codes or orbital propagation routines.

  12. Communication architecture for AAL. Supporting patient care by health care providers in AAL-enhanced living quarters.

    PubMed

    Nitzsche, T; Thiele, S; Häber, A; Winter, A

    2014-01-01

    This article is part of the Focus Theme of Methods of Information in Medicine on "Using Data from Ambient Assisted Living and Smart Homes in Electronic Health Records". Concepts of Ambient Assisted Living (AAL) support a long-term health monitoring and further medical and other services for multi-morbid patients with chronic diseases. In Germany many AAL and telemedical applications exist. Synergy effects by common agreements for essential application components and standards are not achieved. It is necessary to define a communication architecture which is based on common definitions of communication scenarios, application components and communication standards. The development of a communication architecture requires different steps. To gain a reference model for the problem area different AAL and telemedicine projects were compared and relevant data elements were generalized. The derived reference model defines standardized communication links. As a result the authors present an approach towards a reference architecture for AAL-communication. The focus of the architecture lays on the communication layer. The necessary application components are identified and a communication based on standards and their extensions is highlighted. The exchange of patient individual events supported by an event classification model, raw and aggregated data from the personal home area over a telemedicine center to health care providers is possible.

  13. Grading for Understanding--Standards-Based Grading

    ERIC Educational Resources Information Center

    Zimmerman, Todd

    2017-01-01

    Standards-based grading (SBG), sometimes called learning objectives-based assessment (LOBA), is an assessment model that relies on students demonstrating mastery of learning objectives (sometimes referred to as standards). The goal of this grading system is to focus students on mastering learning objectives rather than on accumulating points. I…

  14. Uncertainty evaluation in normalization of isotope delta measurement results against international reference materials.

    PubMed

    Meija, Juris; Chartrand, Michelle M G

    2018-01-01

    Isotope delta measurements are normalized against international reference standards. Although multi-point normalization is becoming a standard practice, the existing uncertainty evaluation practices are either undocumented or are incomplete. For multi-point normalization, we present errors-in-variables regression models for explicit accounting of the measurement uncertainty of the international standards along with the uncertainty that is attributed to their assigned values. This manuscript presents framework to account for the uncertainty that arises due to a small number of replicate measurements and discusses multi-laboratory data reduction while accounting for inevitable correlations between the laboratories due to the use of identical reference materials for calibration. Both frequentist and Bayesian methods of uncertainty analysis are discussed.

  15. LinkEHR-Ed: a multi-reference model archetype editor based on formal semantics.

    PubMed

    Maldonado, José A; Moner, David; Boscá, Diego; Fernández-Breis, Jesualdo T; Angulo, Carlos; Robles, Montserrat

    2009-08-01

    To develop a powerful archetype editing framework capable of handling multiple reference models and oriented towards the semantic description and standardization of legacy data. The main prerequisite for implementing tools providing enhanced support for archetypes is the clear specification of archetype semantics. We propose a formalization of the definition section of archetypes based on types over tree-structured data. It covers the specialization of archetypes, the relationship between reference models and archetypes and conformance of data instances to archetypes. LinkEHR-Ed, a visual archetype editor based on the former formalization with advanced processing capabilities that supports multiple reference models, the editing and semantic validation of archetypes, the specification of mappings to data sources, and the automatic generation of data transformation scripts, is developed. LinkEHR-Ed is a useful tool for building, processing and validating archetypes based on any reference model.

  16. 24 CFR 3285.103 - Site suitability with design zone maps.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... HOUSING AND URBAN DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Pre-Installation....305(c)(2) of the Manufactured Home Construction and Safety Standards in this chapter. (b) Roof load... § 3280.305(c)(3) of the Manufactured Home Construction and Safety Standards in this chapter. Refer to...

  17. 24 CFR 3285.103 - Site suitability with design zone maps.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... HOUSING AND URBAN DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Pre-Installation....305(c)(2) of the Manufactured Home Construction and Safety Standards in this chapter. (b) Roof load... § 3280.305(c)(3) of the Manufactured Home Construction and Safety Standards in this chapter. Refer to...

  18. 24 CFR 3285.103 - Site suitability with design zone maps.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... HOUSING AND URBAN DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Pre-Installation....305(c)(2) of the Manufactured Home Construction and Safety Standards in this chapter. (b) Roof load... § 3280.305(c)(3) of the Manufactured Home Construction and Safety Standards in this chapter. Refer to...

  19. Endogenous versus exogenous generic reference pricing for pharmaceuticals.

    PubMed

    Antoñanzas, F; Juárez-Castelló, C A; Rodríguez-Ibeas, R

    2017-12-01

    In this paper we carry out a vertical differentiation duopoly model applied to pharmaceutical markets to analyze how endogenous and exogenous generic reference pricing influence competition between generic and branded drugs producers. Unlike the literature, we characterize for the exogenous case the equilibrium prices for all feasible relevant reference prices. Competition is enhanced after the introduction of a reference pricing system. We also compare both reference pricing systems on welfare grounds, assuming two different objective functions for health authorities: (i) standard social welfare and (ii) gross consumer surplus net of total pharmaceutical expenditures. We show that regardless of the objective function, health authorities will never choose endogenous reference pricing. When health authorities are paternalistic, the exogenous reference price that maximizes standard social welfare is such that the price of the generic drug is the reference price while the price of the branded drug is higher than the reference price. When health authorities are not paternalistic, the optimal exogenous reference price is such that the price of the branded drug is the reference price while the price of the generic drug is lower than the reference price.

  20. Current state of the mass storage system reference model

    NASA Technical Reports Server (NTRS)

    Coyne, Robert

    1993-01-01

    IEEE SSSWG was chartered in May 1990 to abstract the hardware and software components of existing and emerging storage systems and to define the software interfaces between these components. The immediate goal is the decomposition of a storage system into interoperable functional modules which vendors can offer as separate commercial products. The ultimate goal is to develop interoperable standards which define the software interfaces, and in the distributed case, the associated protocols to each of the architectural modules in the model. The topics are presented in viewgraph form and include the following: IEEE SSSWG organization; IEEE SSSWG subcommittees & chairs; IEEE standards activity board; layered view of the reference model; layered access to storage services; IEEE SSSWG emphasis; and features for MSSRM version 5.

  1. Basic Restriction and Reference Level in Anatomically-based Japanese Models for Low-Frequency Electric and Magnetic Field Exposures

    NASA Astrophysics Data System (ADS)

    Takano, Yukinori; Hirata, Akimasa; Fujiwara, Osamu

    Human exposed to electric and/or magnetic fields at low frequencies may cause direct effect such as nerve stimulation and excitation. Therefore, basic restriction is regulated in terms of induced current density in the ICNIRP guidelines and in-situ electric field in the IEEE standard. External electric or magnetic field which does not produce induced quantities exceeding the basic restriction is used as a reference level. The relationship between the basic restriction and reference level for low-frequency electric and magnetic fields has been investigated using European anatomic models, while limited for Japanese model, especially for electric field exposures. In addition, that relationship has not well been discussed. In the present study, we calculated the induced quantities in anatomic Japanese male and female models exposed to electric and magnetic fields at reference level. A quasi static finite-difference time-domain (FDTD) method was applied to analyze this problem. As a result, spatially averaged induced current density was found to be more sensitive to averaging algorithms than that of in-situ electric field. For electric and magnetic field exposure at the ICNIRP reference level, the maximum values of the induced current density for different averaging algorithm were smaller than the basic restriction for most cases. For exposures at the reference level in the IEEE standard, the maximum electric fields in the brain were larger than the basic restriction in the brain while smaller for the spinal cord and heart.

  2. Accuracy and Specific Value of Cardiovascular 3D-Models in Pediatric CT-Angiography.

    PubMed

    Hammon, Matthias; Rompel, Oliver; Seuss, Hannes; Dittrich, Sven; Uder, Michael; Rüffer, Andrè; Cesnjevar, Robert; Ehret, Nicole; Glöckler, Martin

    2017-12-01

    Computed tomography (CT)-angiography is routinely performed prior to catheter-based and surgical treatment in congenital heart disease. To date, little is known about the accuracy and advantage of different 3D-reconstructions in CT-data. Exact anatomical information is crucial. We analyzed 35 consecutive CT-angiographies of infants with congenital heart disease. All datasets are reconstructed three-dimensionally using volume rendering technique (VRT) and threshold-based segmentation (stereolithographic model, STL). Additionally, the two-dimensional maximum intensity projection (MIP) reconstructs two-dimensional data. In each dataset and resulting image, measurements of vascular diameters for four different vessels were estimated and compared to the reference standard, measured via multiplanar reformation (MPR). The resulting measurements obtained via the STL-images, MIP-images, and the VRT-images were compared with the reference standard. There was a significant difference (p < 0.05) between measurements. The mean difference was 0.0 for STL-images, -0.1 for MIP-images, and -0.3 for VRT-images. The range of the differences was -0.7 to 1.0 mm for STL-images, -0.6 to 0.5 mm for MIP-images and -1.1 to 0.7 mm for VRT-images. There was an excellent correlation between the STL-, MIP-, VRT-measurements, and the reference standard. Inter-reader reliability was excellent (p < 0.01). STL-models of cardiovascular structures are more accurate than the traditional VRT-models. Additionally, they can be standardized and are reproducible.

  3. [Establishment of database with standard 3D tooth crowns based on 3DS MAX].

    PubMed

    Cheng, Xiaosheng; An, Tao; Liao, Wenhe; Dai, Ning; Yu, Qing; Lu, Peijun

    2009-08-01

    The database with standard 3D tooth crowns has laid the groundwork for dental CAD/CAM system. In this paper, we design the standard tooth crowns in 3DS MAX 9.0 and create a database with these models successfully. Firstly, some key lines are collected from standard tooth pictures. Then we use 3DS MAX 9.0 to design the digital tooth model based on these lines. During the design process, it is important to refer to the standard plaster tooth model. After some tests, the standard tooth models designed with this method are accurate and adaptable; furthermore, it is very easy to perform some operations on the models such as deforming and translating. This method provides a new idea to build the database with standard 3D tooth crowns and a basis for dental CAD/CAM system.

  4. Protocol standards and implementation within the digital engineering laboratory computer network (DELNET) using the universal network interface device (UNID). Part 2

    NASA Astrophysics Data System (ADS)

    Phister, P. W., Jr.

    1983-12-01

    Development of the Air Force Institute of Technology's Digital Engineering Laboratory Network (DELNET) was continued with the development of an initial draft of a protocol standard for all seven layers as specified by the International Standards Organization's (ISO) Reference Model for Open Systems Interconnections. This effort centered on the restructuring of the Network Layer to perform Datagram routing and to conform to the developed protocol standards and actual software module development of the upper four protocol layers residing within the DELNET Monitor (Zilog MCZ 1/25 Computer System). Within the guidelines of the ISO Reference Model the Transport Layer was developed utilizing the Internet Header Format (IHF) combined with the Transport Control Protocol (TCP) to create a 128-byte Datagram. Also a limited Application Layer was created to pass the Gettysburg Address through the DELNET. This study formulated a first draft for the DELNET Protocol Standard and designed, implemented, and tested the Network, Transport, and Application Layers to conform to these protocol standards.

  5. Output Feedback Adaptive Control of Non-Minimum Phase Systems Using Optimal Control Modification

    NASA Technical Reports Server (NTRS)

    Nguyen, Nhan; Hashemi, Kelley E.; Yucelen, Tansel; Arabi, Ehsan

    2018-01-01

    This paper describes output feedback adaptive control approaches for non-minimum phase SISO systems with relative degree 1 and non-strictly positive real (SPR) MIMO systems with uniform relative degree 1 using the optimal control modification method. It is well-known that the standard model-reference adaptive control (MRAC) cannot be used to control non-SPR plants to track an ideal SPR reference model. Due to the ideal property of asymptotic tracking, MRAC attempts an unstable pole-zero cancellation which results in unbounded signals for non-minimum phase SISO systems. The optimal control modification can be used to prevent the unstable pole-zero cancellation which results in a stable adaptation of non-minimum phase SISO systems. However, the tracking performance using this approach could suffer if the unstable zero is located far away from the imaginary axis. The tracking performance can be recovered by using an observer-based output feedback adaptive control approach which uses a Luenberger observer design to estimate the state information of the plant. Instead of explicitly specifying an ideal SPR reference model, the reference model is established from the linear quadratic optimal control to account for the non-minimum phase behavior of the plant. With this non-minimum phase reference model, the observer-based output feedback adaptive control can maintain stability as well as tracking performance. However, in the presence of the mismatch between the SPR reference model and the non-minimum phase plant, the standard MRAC results in unbounded signals, whereas a stable adaptation can be achieved with the optimal control modification. An application of output feedback adaptive control for a flexible wing aircraft illustrates the approaches.

  6. The Uhlenbeck-Ford model: Exact virial coefficients and application as a reference system in fluid-phase free-energy calculations

    NASA Astrophysics Data System (ADS)

    Paula Leite, Rodolfo; Freitas, Rodrigo; Azevedo, Rodolfo; de Koning, Maurice

    2016-11-01

    The Uhlenbeck-Ford (UF) model was originally proposed for the theoretical study of imperfect gases, given that all its virial coefficients can be evaluated exactly, in principle. Here, in addition to computing the previously unknown coefficients B11 through B13, we assess its applicability as a reference system in fluid-phase free-energy calculations using molecular simulation techniques. Our results demonstrate that, although the UF model itself is too soft, appropriately scaled Uhlenbeck-Ford (sUF) models provide robust reference systems that allow accurate fluid-phase free-energy calculations without the need for an intermediate reference model. Indeed, in addition to the accuracy with which their free energies are known and their convenient scaling properties, the fluid is the only thermodynamically stable phase for a wide range of sUF models. This set of favorable properties may potentially put the sUF fluid-phase reference systems on par with the standard role that harmonic and Einstein solids play as reference systems for solid-phase free-energy calculations.

  7. OSI: Will It Ever See the Light of Day?

    ERIC Educational Resources Information Center

    Moloney, Peter

    1997-01-01

    Examines issues of viability and necessity regarding the Open System Interconnections (OSI) reference service model with a view on future developments. Discusses problems with the standards; conformance testing; OSI bureaucracy; standardized communications; security; the transport level; applications; the stakeholders (communications providers,…

  8. Using a logical information model-driven design process in healthcare.

    PubMed

    Cheong, Yu Chye; Bird, Linda; Tun, Nwe Ni; Brooks, Colleen

    2011-01-01

    A hybrid standards-based approach has been adopted in Singapore to develop a Logical Information Model (LIM) for healthcare information exchange. The Singapore LIM uses a combination of international standards, including ISO13606-1 (a reference model for electronic health record communication), ISO21090 (healthcare datatypes), SNOMED CT (healthcare terminology) and HL7 v2 (healthcare messaging). This logic-based design approach also incorporates mechanisms for achieving bi-directional semantic interoperability.

  9. Analysis of household refrigerators for different testing standards

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bansal, P.K.; McGill, I.

    This study highlights the salient differences among various testing standards for household refrigerator-freezers and proposes a methodology for predicting the performance of a single evaporator-based vapor-compression refrigeration system (either refrigerator or freezer) from one test standard (where the test data are available-the reference case) to another (the alternative case). The standards studied during this investigation include the Australian-New Zealand Standard (ANZS), the International Standard (ISO), the American National Standard (ANSI), the Japanese Industrial Standard (JIS), and the Chinese National Standard (CNS). A simple analysis in conjunction with the BICYCLE model (Bansal and Rice 1993) is used to calculate the energymore » consumption of two refrigerator cabinets from the reference case to the alternative cases. The proposed analysis includes the effect of door openings (as required by the JIS) as well as defrost heaters. The analytical results are found to agree reasonably well with the experimental observations for translating energy consumption information from one standard to another.« less

  10. Model reference adaptive control (MRAC)-based parameter identification applied to surface-mounted permanent magnet synchronous motor

    NASA Astrophysics Data System (ADS)

    Zhong, Chongquan; Lin, Yaoyao

    2017-11-01

    In this work, a model reference adaptive control-based estimated algorithm is proposed for online multi-parameter identification of surface-mounted permanent magnet synchronous machines. By taking the dq-axis equations of a practical motor as the reference model and the dq-axis estimation equations as the adjustable model, a standard model-reference-adaptive-system-based estimator was established. Additionally, the Popov hyperstability principle was used in the design of the adaptive law to guarantee accurate convergence. In order to reduce the oscillation of identification result, this work introduces a first-order low-pass digital filter to improve precision regarding the parameter estimation. The proposed scheme was then applied to an SPM synchronous motor control system without any additional circuits and implemented using a DSP TMS320LF2812. For analysis, the experimental results reveal the effectiveness of the proposed method.

  11. Evolution of an Implementation-Ready Interprofessional Pain Assessment Reference Model

    PubMed Central

    Collins, Sarah A; Bavuso, Karen; Swenson, Mary; Suchecki, Christine; Mar, Perry; Rocha, Roberto A.

    2017-01-01

    Standards to increase consistency of comprehensive pain assessments are important for safety, quality, and analytics activities, including meeting Joint Commission requirements and learning the best management strategies and interventions for the current prescription Opioid epidemic. In this study we describe the development and validation of a Pain Assessment Reference Model ready for implementation on EHR forms and flowsheets. Our process resulted in 5 successive revisions of the reference model, which more than doubled the number of data elements to 47. The organization of the model evolved during validation sessions with panels totaling 48 subject matter experts (SMEs) to include 9 sets of data elements, with one set recommended as a minimal data set. The reference model also evolved when implemented into EHR forms and flowsheets, indicating specifications such as cascading logic that are important to inform secondary use of data. PMID:29854125

  12. Low energy stage study. Volume 2: Requirements and candidate propulsion modes. [orbital launching of shuttle payloads

    NASA Technical Reports Server (NTRS)

    1978-01-01

    A payload mission model covering 129 launches, was examined and compared against the space transportation system shuttle standard orbit inclinations and a shuttle launch site implementation schedule. Based on this examination and comparison, a set of six reference missions were defined in terms of spacecraft weight and velocity requirements to deliver the payload from a 296 km circular Shuttle standard orbit to the spacecraft's planned orbit. Payload characteristics and requirements representative of the model payloads included in the regime bounded by each of the six reference missions were determined. A set of launch cost envelopes were developed and defined based on the characteristics of existing/planned Shuttle upper stages and expendable launch systems in terms of launch cost and velocity delivered. These six reference missions were used to define the requirements for the candidate propulsion modes which were developed and screened to determine the propulsion approaches for conceptual design.

  13. 0-6759 : developing a business process and logical model to support a tour-based travel demand model design for TxDOT.

    DOT National Transportation Integrated Search

    2013-08-01

    The Texas Department of Transportation : (TxDOT) created a standardized trip-based : modeling approach for travel demand modeling : called the Texas Package Suite of Travel Demand : Models (referred to as the Texas Package) to : oversee the travel de...

  14. Open Systems Interconnection.

    ERIC Educational Resources Information Center

    Denenberg, Ray

    1985-01-01

    Discusses the need for standards allowing computer-to-computer communication and gives examples of technical issues. The seven-layer framework of the Open Systems Interconnection (OSI) Reference Model is explained and illustrated. Sidebars feature public data networks and Recommendation X.25, OSI standards, OSI layer functions, and a glossary.…

  15. The fourth radiation transfer model intercomparison (RAMI-IV): Proficiency testing of canopy reflectance models with ISO-13528

    NASA Astrophysics Data System (ADS)

    Widlowski, J.-L.; Pinty, B.; Lopatka, M.; Atzberger, C.; Buzica, D.; Chelle, M.; Disney, M.; Gastellu-Etchegorry, J.-P.; Gerboles, M.; Gobron, N.; Grau, E.; Huang, H.; Kallel, A.; Kobayashi, H.; Lewis, P. E.; Qin, W.; Schlerf, M.; Stuckens, J.; Xie, D.

    2013-07-01

    The radiation transfer model intercomparison (RAMI) activity aims at assessing the reliability of physics-based radiative transfer (RT) models under controlled experimental conditions. RAMI focuses on computer simulation models that mimic the interactions of radiation with plant canopies. These models are increasingly used in the development of satellite retrieval algorithms for terrestrial essential climate variables (ECVs). Rather than applying ad hoc performance metrics, RAMI-IV makes use of existing ISO standards to enhance the rigor of its protocols evaluating the quality of RT models. ISO-13528 was developed "to determine the performance of individual laboratories for specific tests or measurements." More specifically, it aims to guarantee that measurement results fall within specified tolerance criteria from a known reference. Of particular interest to RAMI is that ISO-13528 provides guidelines for comparisons where the true value of the target quantity is unknown. In those cases, "truth" must be replaced by a reliable "conventional reference value" to enable absolute performance tests. This contribution will show, for the first time, how the ISO-13528 standard developed by the chemical and physical measurement communities can be applied to proficiency testing of computer simulation models. Step by step, the pre-screening of data, the identification of reference solutions, and the choice of proficiency statistics will be discussed and illustrated with simulation results from the RAMI-IV "abstract canopy" scenarios. Detailed performance statistics of the participating RT models will be provided and the role of the accuracy of the reference solutions as well as the choice of the tolerance criteria will be highlighted.

  16. Modeling the Eclipse

    ERIC Educational Resources Information Center

    Thornburgh, William R.; Tretter, Thomas R.

    2017-01-01

    This article describes a unit in which students investigate total solar eclipses, such as the one coming August 21, from several perspectives. It incorporates mathematical thinking and aligns with the "Next Generation Science Standard." This article refers to physical, virtual, and mathematical modeling. Various models and perspectives…

  17. Development of a Comprehensive Osteochondral Allograft MRI Scoring System (OCAMRISS) With Histopathologic, Micro–Computed Tomography, and Biomechanical Validation

    PubMed Central

    Pallante-Kichura, Andrea L.; Bae, Won C.; Du, Jiang; Statum, Sheronda; Wolfson, Tanya; Gamst, Anthony C.; Cory, Esther; Amiel, David; Bugbee, William D.; Sah, Robert L.; Chung, Christine B.

    2014-01-01

    Objective: To describe and apply a semiquantitative MRI scoring system for multifeature analysis of cartilage defect repair in the knee by osteochondral allografts and to correlate this scoring system with histopathologic, micro–computed tomography (µCT), and biomechanical reference standards using a goat repair model. Design: Fourteen adult goats had 2 osteochondral allografts implanted into each knee: one in the medial femoral condyle and one in the lateral trochlea. At 12 months, goats were euthanized and MRI was performed. Two blinded radiologists independently rated 9 primary features for each graft, including cartilage signal, fill, edge integration, surface congruity, calcified cartilage integrity, subchondral bone plate congruity, subchondral bone marrow signal, osseous integration, and presence of cystic changes. Four ancillary features of the joint were also evaluated, including opposing cartilage, meniscal tears, synovitis, and fat-pad scarring. Comparison was made with histologic and µCT reference standards as well as biomechanical measures. Interobserver agreement and agreement with reference standards was assessed. Cohen’s κ, Spearman’s correlation, and Kruskal-Wallis tests were used as appropriate. Results: There was substantial agreement (κ > 0.6, P < 0.001) for each MRI feature and with comparison against reference standards, except for cartilage edge integration (κ = 0.6). There was a strong positive correlation between MRI and reference standard scores (ρ = 0.86, P < 0.01). Osteochondral allograft MRI scoring system was sensitive to differences in outcomes between the types of allografts. Conclusions: We have described a comprehensive MRI scoring system for osteochondral allografts and have validated this scoring system with histopathologic and µCT reference standards as well as biomechanical indentation testing. PMID:24489999

  18. Quantification of drugs in plasma without primary reference standards by liquid chromatography-chemiluminescence nitrogen detection: application to tramadol metabolite ratios.

    PubMed

    Ojanperä, Suvi; Rasanen, Ilpo; Sistonen, Johanna; Pelander, Anna; Vuori, Erkki; Ojanperä, Ilkka

    2007-08-01

    Lack of availability of reference standards for drug metabolites, newly released drugs, and illicit drugs hinders the analysis of these substances in biologic samples. To counter this problem, an approach is presented here for quantitative drug analysis in plasma without primary reference standards by liquid chromatography-chemiluminescence nitrogen detection (LC-CLND). To demonstrate the feasibility of the method, metabolic ratios of the opioid drug tramadol were determined in the setting of a pharmacogenetic study. Four volunteers were given a single 100-mg oral dose of tramadol, and a blood sample was collected from each subject 1 hour later. Tramadol, O-desmethyltramadol, and nortramadol were determined in plasma by LC-CLND without reference standards and by a gas chromatography-mass spectrometry reference method. In contrast to previous CLND studies lacking an extraction step, a liquid-liquid extraction system was created for 5-mL plasma samples using n-butyl chloride-isopropyl alcohol (98 + 2) at pH 10. Extraction recovery estimation was based on model compounds chosen according to their similar physicochemical characteristics (retention time, pKa, logD). Instrument calibration was performed with a single secondary standard (caffeine) using the equimolar response of the detector to nitrogen. The mean differences between the results of the LC-CLND and gas chromatography-mass spectrometry methods for tramadol, O-desmethyltramadol, and nortramadol were 8%, 32%, and 19%, respectively. The sensitivity of LC-CLND was sufficient for therapeutic concentrations of tramadol and metabolites. A good correlation was obtained between genotype, expressed by the number of functional genes, and the plasma metabolite ratios. This experiment suggests that a recovery-corrected LC-CLND analysis produces sufficiently accurate results to be useful in a clinical context, particularly in instances in which reference standards are not readily accessible.

  19. A new item response theory model to adjust data allowing examinee choice

    PubMed Central

    Costa, Marcelo Azevedo; Braga Oliveira, Rivert Paulo

    2018-01-01

    In a typical questionnaire testing situation, examinees are not allowed to choose which items they answer because of a technical issue in obtaining satisfactory statistical estimates of examinee ability and item difficulty. This paper introduces a new item response theory (IRT) model that incorporates information from a novel representation of questionnaire data using network analysis. Three scenarios in which examinees select a subset of items were simulated. In the first scenario, the assumptions required to apply the standard Rasch model are met, thus establishing a reference for parameter accuracy. The second and third scenarios include five increasing levels of violating those assumptions. The results show substantial improvements over the standard model in item parameter recovery. Furthermore, the accuracy was closer to the reference in almost every evaluated scenario. To the best of our knowledge, this is the first proposal to obtain satisfactory IRT statistical estimates in the last two scenarios. PMID:29389996

  20. CCR+: Metadata Based Extended Personal Health Record Data Model Interoperable with the ASTM CCR Standard.

    PubMed

    Park, Yu Rang; Yoon, Young Jo; Jang, Tae Hun; Seo, Hwa Jeong; Kim, Ju Han

    2014-01-01

    Extension of the standard model while retaining compliance with it is a challenging issue because there is currently no method for semantically or syntactically verifying an extended data model. A metadata-based extended model, named CCR+, was designed and implemented to achieve interoperability between standard and extended models. Furthermore, a multilayered validation method was devised to validate the standard and extended models. The American Society for Testing and Materials (ASTM) Community Care Record (CCR) standard was selected to evaluate the CCR+ model; two CCR and one CCR+ XML files were evaluated. In total, 188 metadata were extracted from the ASTM CCR standard; these metadata are semantically interconnected and registered in the metadata registry. An extended-data-model-specific validation file was generated from these metadata. This file can be used in a smartphone application (Health Avatar CCR+) as a part of a multilayered validation. The new CCR+ model was successfully evaluated via a patient-centric exchange scenario involving multiple hospitals, with the results supporting both syntactic and semantic interoperability between the standard CCR and extended, CCR+, model. A feasible method for delivering an extended model that complies with the standard model is presented herein. There is a great need to extend static standard models such as the ASTM CCR in various domains: the methods presented here represent an important reference for achieving interoperability between standard and extended models.

  1. NASA Standard for Models and Simulations: Credibility Assessment Scale

    NASA Technical Reports Server (NTRS)

    Babula, Maria; Bertch, William J.; Green, Lawrence L.; Hale, Joseph P.; Moser, Gary E.; Steele, Martin J.; Sylvester, Andre; Woods, Jody

    2008-01-01

    As one of its many responses to the 2003 Space Shuttle Columbia accident, NASA decided to develop a formal standard for models and simulations (M and S)ii. Work commenced in May 2005. An interim version was issued in late 2006. This interim version underwent considerable revision following an extensive Agency-wide review in 2007 along with some additional revisions as a result of the review by the NASA Engineering Management Board (EMB) in the first half of 2008. Issuance of the revised, permanent version,hereafter referred to as the M and S Standard or just the Standard, occurred in July 2008.

  2. Query Health: standards-based, cross-platform population health surveillance

    PubMed Central

    Klann, Jeffrey G; Buck, Michael D; Brown, Jeffrey; Hadley, Marc; Elmore, Richard; Weber, Griffin M; Murphy, Shawn N

    2014-01-01

    Objective Understanding population-level health trends is essential to effectively monitor and improve public health. The Office of the National Coordinator for Health Information Technology (ONC) Query Health initiative is a collaboration to develop a national architecture for distributed, population-level health queries across diverse clinical systems with disparate data models. Here we review Query Health activities, including a standards-based methodology, an open-source reference implementation, and three pilot projects. Materials and methods Query Health defined a standards-based approach for distributed population health queries, using an ontology based on the Quality Data Model and Consolidated Clinical Document Architecture, Health Quality Measures Format (HQMF) as the query language, the Query Envelope as the secure transport layer, and the Quality Reporting Document Architecture as the result language. Results We implemented this approach using Informatics for Integrating Biology and the Bedside (i2b2) and hQuery for data analytics and PopMedNet for access control, secure query distribution, and response. We deployed the reference implementation at three pilot sites: two public health departments (New York City and Massachusetts) and one pilot designed to support Food and Drug Administration post-market safety surveillance activities. The pilots were successful, although improved cross-platform data normalization is needed. Discussions This initiative resulted in a standards-based methodology for population health queries, a reference implementation, and revision of the HQMF standard. It also informed future directions regarding interoperability and data access for ONC's Data Access Framework initiative. Conclusions Query Health was a test of the learning health system that supplied a functional methodology and reference implementation for distributed population health queries that has been validated at three sites. PMID:24699371

  3. Query Health: standards-based, cross-platform population health surveillance.

    PubMed

    Klann, Jeffrey G; Buck, Michael D; Brown, Jeffrey; Hadley, Marc; Elmore, Richard; Weber, Griffin M; Murphy, Shawn N

    2014-01-01

    Understanding population-level health trends is essential to effectively monitor and improve public health. The Office of the National Coordinator for Health Information Technology (ONC) Query Health initiative is a collaboration to develop a national architecture for distributed, population-level health queries across diverse clinical systems with disparate data models. Here we review Query Health activities, including a standards-based methodology, an open-source reference implementation, and three pilot projects. Query Health defined a standards-based approach for distributed population health queries, using an ontology based on the Quality Data Model and Consolidated Clinical Document Architecture, Health Quality Measures Format (HQMF) as the query language, the Query Envelope as the secure transport layer, and the Quality Reporting Document Architecture as the result language. We implemented this approach using Informatics for Integrating Biology and the Bedside (i2b2) and hQuery for data analytics and PopMedNet for access control, secure query distribution, and response. We deployed the reference implementation at three pilot sites: two public health departments (New York City and Massachusetts) and one pilot designed to support Food and Drug Administration post-market safety surveillance activities. The pilots were successful, although improved cross-platform data normalization is needed. This initiative resulted in a standards-based methodology for population health queries, a reference implementation, and revision of the HQMF standard. It also informed future directions regarding interoperability and data access for ONC's Data Access Framework initiative. Query Health was a test of the learning health system that supplied a functional methodology and reference implementation for distributed population health queries that has been validated at three sites. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  4. Designing Excellence and Quality Model for Training Centers of Primary Health Care: A Delphi Method Study.

    PubMed

    Tabrizi, Jafar-Sadegh; Farahbakhsh, Mostafa; Shahgoli, Javad; Rahbar, Mohammad Reza; Naghavi-Behzad, Mohammad; Ahadi, Hamid-Reza; Azami-Aghdash, Saber

    2015-10-01

    Excellence and quality models are comprehensive methods for improving the quality of healthcare. The aim of this study was to design excellence and quality model for training centers of primary health care using Delphi method. In this study, Delphi method was used. First, comprehensive information were collected using literature review. In extracted references, 39 models were identified from 34 countries and related sub-criteria and standards were extracted from 34 models (from primary 39 models). Then primary pattern including 8 criteria, 55 sub-criteria, and 236 standards was developed as a Delphi questionnaire and evaluated in four stages by 9 specialists of health care system in Tabriz and 50 specialists from all around the country. Designed primary model (8 criteria, 55 sub-criteria, and 236 standards) were concluded with 8 criteria, 45 sub-criteria, and 192 standards after 4 stages of evaluations by specialists. Major criteria of the model are leadership, strategic and operational planning, resource management, information analysis, human resources management, process management, costumer results, and functional results, where the top score was assigned as 1000 by specialists. Functional results had the maximum score of 195 whereas planning had the minimum score of 60. Furthermore the most and the least sub-criteria was for leadership with 10 sub-criteria and strategic planning with 3 sub-criteria, respectively. The model that introduced in this research has been designed following 34 reference models of the world. This model could provide a proper frame for managers of health system in improving quality.

  5. Mass storage system reference model, Version 4

    NASA Technical Reports Server (NTRS)

    Coleman, Sam (Editor); Miller, Steve (Editor)

    1993-01-01

    The high-level abstractions that underlie modern storage systems are identified. The information to generate the model was collected from major practitioners who have built and operated large storage facilities, and represents a distillation of the wisdom they have acquired over the years. The model provides a common terminology and set of concepts to allow existing systems to be examined and new systems to be discussed and built. It is intended that the model and the interfaces identified from it will allow and encourage vendors to develop mutually-compatible storage components that can be combined to form integrated storage systems and services. The reference model presents an abstract view of the concepts and organization of storage systems. From this abstraction will come the identification of the interfaces and modules that will be used in IEEE storage system standards. The model is not yet suitable as a standard; it does not contain implementation decisions, such as how abstract objects should be broken up into software modules or how software modules should be mapped to hosts; it does not give policy specifications, such as when files should be migrated; does not describe how the abstract objects should be used or connected; and does not refer to specific hardware components. In particular, it does not fully specify the interfaces.

  6. Contribution of the International Reference Ionosphere to the progress of the ionospheric representation

    NASA Astrophysics Data System (ADS)

    Bilitza, Dieter

    2017-04-01

    The International Reference Ionosphere (IRI), a joint project of the Committee on Space Research (COSPAR) and the International Union of Radio Science (URSI), is a data-based reference model for the ionosphere and since 2014 it is also recognized as the ISO (International Standardization Organization) standard for the ionosphere. The model is a synthesis of most of the available and reliable observations of ionospheric parameters combining ground and space measurements. This presentation reviews the steady progress in achieving a more and more accurate representation of the ionospheric plasma parameters accomplished during the last decade of IRI model improvements. Understandably, a data-based model is only as good as the data foundation on which it is built. We will discuss areas where we are in need of more data to obtain a more solid and continuous data foundation in space and time. We will also take a look at still existing discrepancies between simultaneous measurements of the same parameter with different measurement techniques and discuss the approach taken in the IRI model to deal with these conflicts. In conclusion we will provide an outlook at development activities that may result in significant future improvements of the accurate representation of the ionosphere in the IRI model.

  7. Predicting fertility.

    PubMed

    Maheshwari, Abha; Bhattacharya, Siladitya; Johnson, Neil P

    2008-06-01

    Various predictors of fertility have been described, suggesting that none are ideal. The literature on tests of ovarian reserve is largely limited to women undergoing in vitro fertilization, and is reliant on the use of surrogate markers, such as cycle cancellation and number of oocytes retrieved, as reference standards. Currently available prediction models are far from ideal; most are applicable only to subfertile women seeking assisted reproduction, and lack external validation. Systematic reviews and meta-analyses of predictors of fertility are limited by their heterogeneity in terms of the population sampled, predictors tested and reference standards used. There is an urgent need for consensus in the design of these studies, definition of abnormal tests, and, above all, a need to use robust outcomes such as live birth as the reference standard. There are no reliable predictors of fertility that can guide women as to how long childbearing can be deferred.

  8. Creating Royal Australian Navy Standard Operating Procedures using Flow Diagrams

    DTIC Science & Technology

    2015-08-01

    DST-Group-TR-3137 UNCLASSIFIED Acronyms 4TQ 4TQ Toolkit ABR Australian Book of Reference ADF Australian Defence Force BPMN Business...steps to perform the activity. Object Management Group’s (OMG) Business Process Model and Notation ( BPMN ) [10] is becoming the standard to use when...Department of Defence 10. Object Management Group, Business Process Model and Notation ( BPMN ), version 2.0. 2011, Object Management Group: http

  9. From SCORM to Common Cartridge: A Step Forward

    ERIC Educational Resources Information Center

    Gonzalez-Barbone, Victor; Anido-Rifon, Luis

    2010-01-01

    Shareable Content Object Reference Model (SCORM) was proposed as a standard for sharable learning object packaging, delivering and sequencing. Several years later, Common Cartridge (CC) is proposed as an enhancement of SCORM offering more flexibility and addressing needs not originally envisioned, namely assessment and web 2.0 standards, content…

  10. Theory and Modelling Resources Cookbook

    NASA Astrophysics Data System (ADS)

    Gray, Norman

    This cookbook is intended to assemble references to resources likely to be of interest to theorists and modellers. It's not a collection of standard recipes, but instead a repository of brief introductions to facilities. It includes references to sources of authoritative information, including those Starlink documents most likely to be of interest to theorists. Although the topics are chosen for their relevance to theoretical work, a good proportion of the information should be of interest to all of the astronomical computing community.

  11. Assessing the Mechanisms of MDS and Its Transformation to Leukemia in a Novel Humanized Mouse

    DTIC Science & Technology

    2016-05-01

    achievements N/A References N/A References: 1. Rongvaux, A., et al., Development and function of human innate immune cells in a...in cancer survivors. MDS is inherently difficult to study. MDS stem cells cannot be grown in culture and in vivo models are thus the gold standard...However, MDS stem cells are diseased and fail to efficiently engraft in current immunodeficient mouse models. We have optimized engraftment of

  12. Networking DEC and IBM computers

    NASA Technical Reports Server (NTRS)

    Mish, W. H.

    1983-01-01

    Local Area Networking of DEC and IBM computers within the structure of the ISO-OSI Seven Layer Reference Model at a raw signaling speed of 1 Mops or greater are discussed. After an introduction to the ISO-OSI Reference Model nd the IEEE-802 Draft Standard for Local Area Networks (LANs), there follows a detailed discussion and comparison of the products available from a variety of manufactures to perform this networking task. A summary of these products is presented in a table.

  13. Earth Global Reference Atmospheric Model (GRAM) Overview and Updates: DOLWG Meeting

    NASA Technical Reports Server (NTRS)

    White, Patrick

    2017-01-01

    What is Earth-GRAM (Global Reference Atmospheric Model): Provides monthly mean and standard deviation for any point in atmosphere - Monthly, Geographic, and Altitude Variation; Earth-GRAM is a C++ software package - Currently distributed as Earth-GRAM 2016; Atmospheric variables included: pressure, density, temperature, horizontal and vertical winds, speed of sound, and atmospheric constituents; Used by engineering community because of ability to create dispersions in atmosphere at a rapid runtime - Often embedded in trajectory simulation software; Not a forecast model; Does not readily capture localized atmospheric effects.

  14. Effect of Transitioning from Standard Reference Material 2806a to Standard Reference Material 2806b for Light Obscuration Particle Countering

    DTIC Science & Technology

    2016-04-01

    Reference Material 2806b for Light Obscuration Particle Countering April 2016 UNCLASSIFIED UNCLASSIFIED Joel Schmitigal 27809 Standard Form 298 (Rev...Standard Reference Material 2806b for Light Obscuration Particle Countering 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6...Reference Material 2806a to Standard Reference Material 2806b for Light Obscuration Particle Countering Joel Schmitigal Force Projection

  15. Study on Standard Fatigue Vehicle Load Model

    NASA Astrophysics Data System (ADS)

    Huang, H. Y.; Zhang, J. P.; Li, Y. H.

    2018-02-01

    Based on the measured data of truck from three artery expressways in Guangdong Province, the statistical analysis of truck weight was conducted according to axle number. The standard fatigue vehicle model applied to industrial areas in the middle and late was obtained, which adopted equivalence damage principle, Miner linear accumulation law, water discharge method and damage ratio theory. Compared with the fatigue vehicle model Specified by the current bridge design code, the proposed model has better applicability. It is of certain reference value for the fatigue design of bridge in China.

  16. High precision UTDR measurements by sonic velocity compensation with reference transducer.

    PubMed

    Stade, Sam; Kallioinen, Mari; Mänttäri, Mika; Tuuva, Tuure

    2014-07-02

    An ultrasonic sensor design with sonic velocity compensation is developed to improve the accuracy of distance measurement in membrane modules. High accuracy real-time distance measurements are needed in membrane fouling and compaction studies. The benefits of the sonic velocity compensation with a reference transducer are compared to the sonic velocity calculated with the measured temperature and pressure using the model by Belogol'skii, Sekoyan et al. In the experiments the temperature was changed from 25 to 60 °C at pressures of 0.1, 0.3 and 0.5 MPa. The set measurement distance was 17.8 mm. Distance measurements with sonic velocity compensation were over ten times more accurate than the ones calculated based on the model. Using the reference transducer measured sonic velocity, the standard deviations for the distance measurements varied from 0.6 to 2.0 µm, while using the calculated sonic velocity the standard deviations were 21-39 µm. In industrial liquors, not only the temperature and the pressure, which were studied in this paper, but also the properties of the filtered solution, such as solute concentration, density, viscosity, etc., may vary greatly, leading to inaccuracy in the use of the Belogol'skii, Sekoyan et al. model. Therefore, calibration of the sonic velocity with reference transducers is needed for accurate distance measurements.

  17. 46 CFR 160.052-1 - Incorporation by reference.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., Model AP. Sheet 2—Cutting Pattern and General Arrangement, Model CPM. Sheet 3—Cutting Pattern and General Arrangement, Model CPS. Sheet 4—Insert Patterns. (c) Copies on file. The manufacturer shall keep a... Specifications and Standards may be purchased from the Business Service Center, General Services Administration...

  18. AP233: An Information Model for Systems Engineering

    NASA Technical Reports Server (NTRS)

    Siebes, Georg

    2009-01-01

    In today's world, information is abundant. We have no problems generating it. But we are challenged to find, organize, and exchange information. center dot A standardized model of information can help. Such a model nearly completed its development for Systems Engineering. It is referred to as AP233 (AP = Application Protocol).

  19. Modeling the Zeeman effect in high altitude SSMIS channels for numerical weather prediction profiles: comparing a fast model and a line-by-line model

    NASA Astrophysics Data System (ADS)

    Larsson, R.; Milz, M.; Rayer, P.; Saunders, R.; Bell, W.; Booton, A.; Buehler, S. A.; Eriksson, P.; John, V.

    2015-10-01

    We present a comparison of a reference and a fast radiative transfer model using numerical weather prediction profiles for the Zeeman-affected high altitude Special Sensor Microwave Imager/Sounder channels 19-22. We find that the models agree well for channels 21 and 22 compared to the channels' system noise temperatures (1.9 and 1.3 K, respectively) and the expected profile errors at the affected altitudes (estimated to be around 5 K). For channel 22 there is a 0.5 K average difference between the models, with a standard deviation of 0.24 K for the full set of atmospheric profiles. Same channel, there is 1.2 K in average between the fast model and the sensor measurement, with 1.4 K standard deviation. For channel 21 there is a 0.9 K average difference between the models, with a standard deviation of 0.56 K. Same channel, there is 1.3 K in average between the fast model and the sensor measurement, with 2.4 K standard deviation. We consider the relatively small model differences as a validation of the fast Zeeman effect scheme for these channels. Both channels 19 and 20 have smaller average differences between the models (at below 0.2 K) and smaller standard deviations (at below 0.4 K) when both models use a two-dimensional magnetic field profile. However, when the reference model is switched to using a full three-dimensional magnetic field profile, the standard deviation to the fast model is increased to almost 2 K due to viewing geometry dependencies causing up to ± 7 K differences near the equator. The average differences between the two models remain small despite changing magnetic field configurations. We are unable to compare channels 19 and 20 to sensor measurements due to limited altitude range of the numerical weather prediction profiles. We recommended that numerical weather prediction software using the fast model takes the available fast Zeeman scheme into account for data assimilation of the affected sensor channels to better constrain the upper atmospheric temperatures.

  20. Modeling the Zeeman effect in high-altitude SSMIS channels for numerical weather prediction profiles: comparing a fast model and a line-by-line model

    NASA Astrophysics Data System (ADS)

    Larsson, Richard; Milz, Mathias; Rayer, Peter; Saunders, Roger; Bell, William; Booton, Anna; Buehler, Stefan A.; Eriksson, Patrick; John, Viju O.

    2016-03-01

    We present a comparison of a reference and a fast radiative transfer model using numerical weather prediction profiles for the Zeeman-affected high-altitude Special Sensor Microwave Imager/Sounder channels 19-22. We find that the models agree well for channels 21 and 22 compared to the channels' system noise temperatures (1.9 and 1.3 K, respectively) and the expected profile errors at the affected altitudes (estimated to be around 5 K). For channel 22 there is a 0.5 K average difference between the models, with a standard deviation of 0.24 K for the full set of atmospheric profiles. Concerning the same channel, there is 1.2 K on average between the fast model and the sensor measurement, with 1.4 K standard deviation. For channel 21 there is a 0.9 K average difference between the models, with a standard deviation of 0.56 K. Regarding the same channel, there is 1.3 K on average between the fast model and the sensor measurement, with 2.4 K standard deviation. We consider the relatively small model differences as a validation of the fast Zeeman effect scheme for these channels. Both channels 19 and 20 have smaller average differences between the models (at below 0.2 K) and smaller standard deviations (at below 0.4 K) when both models use a two-dimensional magnetic field profile. However, when the reference model is switched to using a full three-dimensional magnetic field profile, the standard deviation to the fast model is increased to almost 2 K due to viewing geometry dependencies, causing up to ±7 K differences near the equator. The average differences between the two models remain small despite changing magnetic field configurations. We are unable to compare channels 19 and 20 to sensor measurements due to limited altitude range of the numerical weather prediction profiles. We recommended that numerical weather prediction software using the fast model takes the available fast Zeeman scheme into account for data assimilation of the affected sensor channels to better constrain the upper atmospheric temperatures.

  1. Evaluation of reference genes for quantitative RT-PCR in Lolium temulentum under abiotic stress

    USDA-ARS?s Scientific Manuscript database

    Lolium temulentum is a valuable model grass species for the study of stress in forage and turf grasses. Gene expression analysis by quantitative real time RT-PCR relies on the use of proper internal standards. The aim of this study was to identify and evaluate reference genes for use in real-time q...

  2. Impact of a product-specific reference standard for the measurement of a PEGylated rFVIII activity: the Swiss Multicentre Field Study.

    PubMed

    Bulla, O; Poncet, A; Alberio, L; Asmis, L M; Gähler, A; Graf, L; Nagler, M; Studt, J-D; Tsakiris, D A; Fontana, P

    2017-07-01

    Measuring factor VIII (FVIII) activity can be challenging when it has been modified, such as when FVIII is pegylated to increase its circulating half-life. Use of a product-specific reference standard may help avoid this issue. Evaluate the impact of using a product-specific reference standard for measuring the FVIII activity of BAX 855 - a pegylated FVIII - in eight of Switzerland's main laboratories. Factor VIII-deficient plasma, spiked with five different concentrations of BAX 855, plus a control FVIII sample, was sent to the participating laboratories. They measured FVIII activity by using either with a one-stage (OSA) or the chromogenic assay (CA) against their local or a product-specific reference standard. When using a local reference standard, there was an overestimation of BAX 855 activity compared to the target concentrations, both with the OSA and CA. The use of a product-specific reference standard reduced this effect: mean recovery ranged from 127.7% to 213.5% using the OSA with local reference standards, compared to 110% to 183.8% with a product-specific reference standard, and from 146.3% to 182.4% using the CA with local reference standards compared to 72.7% to 103.7% with a product-specific reference standard. In this in vitro study, the type of reference standard had a major impact on the measurement of BAX 855 activity. Evaluation was more accurate and precise when using a product-specific reference standard. © 2017 John Wiley & Sons Ltd.

  3. Dosimetry for Small and Nonstandard Fields

    NASA Astrophysics Data System (ADS)

    Junell, Stephanie L.

    The proposed small and non-standard field dosimetry protocol from the joint International Atomic Energy Agency (IAEA) and American Association of Physicist in Medicine working group introduces new reference field conditions for ionization chamber based reference dosimetry. Absorbed dose beam quality conversion factors (kQ factors) corresponding to this formalism were determined for three different models of ionization chambers: a Farmer-type ionization chamber, a thimble ionization chamber, and a small volume ionization chamber. Beam quality correction factor measurements were made in a specially developed cylindrical polymethyl methacrylate (PMMA) phantom and a water phantom using thermoluminescent dosimeters (TLDs) and alanine dosimeters to determine dose to water. The TLD system for absorbed dose to water determination in high energy photon and electron beams was fully characterized as part of this dissertation. The behavior of the beam quality correction factor was observed as it transfers the calibration coefficient from the University of Wisconsin Accredited Dosimetry Calibration Laboratory (UWADCL) 60Co reference beam to the small field calibration conditions of the small field formalism. TLD-determined beam quality correction factors for the calibration conditions investigated ranged from 0.97 to 1.30 and had associated standard deviations from 1% to 3%. The alanine-determined beam quality correction factors ranged from 0.996 to 1.293. Volume averaging effects were observed with the Farmer-type ionization chamber in the small static field conditions. The proposed small and non-standard field dosimetry protocols new composite-field reference condition demonstrated its potential to reduce or remove ionization chamber volume dependancies, but the measured beam quality correction factors were not equal to the standard CoP's kQ, indicating a change in beam quality in the small and non-standard field dosimetry protocols new composite-field reference condition relative to the standard broad beam reference conditions. The TLD- and alanine-determined beam quality correction factors in the composite-field reference conditions were approximately 3% greater and differed by more than one standard deviation from the published TG-51 kQ values for all three chambers.

  4. CCR+: Metadata Based Extended Personal Health Record Data Model Interoperable with the ASTM CCR Standard

    PubMed Central

    Park, Yu Rang; Yoon, Young Jo; Jang, Tae Hun; Seo, Hwa Jeong

    2014-01-01

    Objectives Extension of the standard model while retaining compliance with it is a challenging issue because there is currently no method for semantically or syntactically verifying an extended data model. A metadata-based extended model, named CCR+, was designed and implemented to achieve interoperability between standard and extended models. Methods Furthermore, a multilayered validation method was devised to validate the standard and extended models. The American Society for Testing and Materials (ASTM) Community Care Record (CCR) standard was selected to evaluate the CCR+ model; two CCR and one CCR+ XML files were evaluated. Results In total, 188 metadata were extracted from the ASTM CCR standard; these metadata are semantically interconnected and registered in the metadata registry. An extended-data-model-specific validation file was generated from these metadata. This file can be used in a smartphone application (Health Avatar CCR+) as a part of a multilayered validation. The new CCR+ model was successfully evaluated via a patient-centric exchange scenario involving multiple hospitals, with the results supporting both syntactic and semantic interoperability between the standard CCR and extended, CCR+, model. Conclusions A feasible method for delivering an extended model that complies with the standard model is presented herein. There is a great need to extend static standard models such as the ASTM CCR in various domains: the methods presented here represent an important reference for achieving interoperability between standard and extended models. PMID:24627817

  5. Modeling Canadian Quality Control Test Program for Steroid Hormone Receptors in Breast Cancer: Diagnostic Accuracy Study.

    PubMed

    Pérez, Teresa; Makrestsov, Nikita; Garatt, John; Torlakovic, Emina; Gilks, C Blake; Mallett, Susan

    The Canadian Immunohistochemistry Quality Control program monitors clinical laboratory performance for estrogen receptor and progesterone receptor tests used in breast cancer treatment management in Canada. Current methods assess sensitivity and specificity at each time point, compared with a reference standard. We investigate alternative performance analysis methods to enhance the quality assessment. We used 3 methods of analysis: meta-analysis of sensitivity and specificity of each laboratory across all time points; sensitivity and specificity at each time point for each laboratory; and fitting models for repeated measurements to examine differences between laboratories adjusted by test and time point. Results show 88 laboratories participated in quality control at up to 13 time points using typically 37 to 54 histology samples. In meta-analysis across all time points no laboratories have sensitivity or specificity below 80%. Current methods, presenting sensitivity and specificity separately for each run, result in wide 95% confidence intervals, typically spanning 15% to 30%. Models of a single diagnostic outcome demonstrated that 82% to 100% of laboratories had no difference to reference standard for estrogen receptor and 75% to 100% for progesterone receptor, with the exception of 1 progesterone receptor run. Laboratories with significant differences to reference standard identified with Generalized Estimating Equation modeling also have reduced performance by meta-analysis across all time points. The Canadian Immunohistochemistry Quality Control program has a good design, and with this modeling approach has sufficient precision to measure performance at each time point and allow laboratories with a significantly lower performance to be targeted for advice.

  6. On the Execution Control of HLA Federations using the SISO Space Reference FOM

    NASA Technical Reports Server (NTRS)

    Moller, Bjorn; Garro, Alfredo; Falcone, Alberto; Crues, Edwin Z.; Dexter, Daniel E.

    2017-01-01

    In the Space domain the High Level Architecture (HLA) is one of the reference standard for Distributed Simulation. However, for the different organizations involved in the Space domain (e.g. NASA, ESA, Roscosmos, and JAXA) and their industrial partners, it is difficult to implement HLA simulators (called Federates) able to interact and interoperate in the context of a distributed HLA simulation (called Federation). The lack of a common FOM (Federation Object Model) for the Space domain is one of the main reasons that precludes a-priori interoperability between heterogeneous federates. To fill this lack a Product Development Group (PDG) has been recently activated in the Simulation Interoperability Standards Organization (SISO) with the aim to provide a Space Reference FOM (SRFOM) for international collaboration on Space systems simulations. Members of the PDG come from several countries and contribute experiences from projects within NASA, ESA and other organizations. Participants represent government, academia and industry. The paper presents an overview of the ongoing Space Reference FOM standardization initiative by focusing on the solution provided for managing the execution of an SRFOM-based Federation.

  7. Perceptual video quality assessment in H.264 video coding standard using objective modeling.

    PubMed

    Karthikeyan, Ramasamy; Sainarayanan, Gopalakrishnan; Deepa, Subramaniam Nachimuthu

    2014-01-01

    Since usage of digital video is wide spread nowadays, quality considerations have become essential, and industry demand for video quality measurement is rising. This proposal provides a method of perceptual quality assessment in H.264 standard encoder using objective modeling. For this purpose, quality impairments are calculated and a model is developed to compute the perceptual video quality metric based on no reference method. Because of the shuttle difference between the original video and the encoded video the quality of the encoded picture gets degraded, this quality difference is introduced by the encoding process like Intra and Inter prediction. The proposed model takes into account of the artifacts introduced by these spatial and temporal activities in the hybrid block based coding methods and an objective modeling of these artifacts into subjective quality estimation is proposed. The proposed model calculates the objective quality metric using subjective impairments; blockiness, blur and jerkiness compared to the existing bitrate only calculation defined in the ITU G 1070 model. The accuracy of the proposed perceptual video quality metrics is compared against popular full reference objective methods as defined by VQEG.

  8. The rank correlated SLW model of gas radiation in non-uniform media

    NASA Astrophysics Data System (ADS)

    Solovjov, Vladimir P.; Andre, Frederic; Lemonnier, Denis; Webb, Brent W.

    2017-08-01

    A comprehensive theoretical development of possible reference approaches in modelling of radiation transfer in non-uniform gaseous media is developed within the framework of the Generalized SLW Model. The notion of absorption spectrum ;correlation; adopted currently for global methods in gas radiation is critically revisited and replaced by a less restrictive concept of rank correlated spectrum. Within this framework it is shown that eight different reference approaches are possible, of which only three have been reported in the literature. Among the approaches presented is a novel Rank Correlated SLW Model, which is distinguished by the fact that i) it does not require the specification of a reference gas thermodynamic state, and ii) it preserves the emission term in the spectrally integrated Radiative Transfer Equation. Construction of this reference model requires only two absorption line blackbody distribution functions, and subdivision into gray gases can be performed using standard quadratures. Consequently, this new reference approach appears to have significant advantages over all other methods, and is, in general, a significant improvement in the global modelling of gas radiation. All reference approaches are summarized in the present work, and their use in radiative transfer prediction is demonstrated for simple example cases. Further, a detailed rigorous theoretical development of the improved methods is provided.

  9. Interoperability Gap Challenges for Learning Object Repositories & Learning Management Systems

    ERIC Educational Resources Information Center

    Mason, Robert T.

    2011-01-01

    An interoperability gap exists between Learning Management Systems (LMSs) and Learning Object Repositories (LORs). Learning Objects (LOs) and the associated Learning Object Metadata (LOM) that is stored within LORs adhere to a variety of LOM standards. A common LOM standard found in LORs is the Sharable Content Object Reference Model (SCORM)…

  10. The Interlibrary Loan Protocol: An OSI Solution to ILL Messaging.

    ERIC Educational Resources Information Center

    Turner, Fay

    1990-01-01

    Discusses the interlibrary loan (ILL) protocol, a standard based on the principles of the Open Systems Interconnection (OSI) Reference Model. Benefits derived from protocol use are described, the status of the protocol as an international standard is reviewed, and steps taken by the National Library of Canada to facilitate migration to an ILL…

  11. Moving Toward SCORM Compliant Content Production at Educational Software Company: Technical and Administrative Challenges

    ERIC Educational Resources Information Center

    Kultur, Can; Oytun, Erden; Cagiltay, Kursat; Ozden, M. Yasar; Kucuk, Mehmet Emin

    2004-01-01

    The Shareable Content Object Reference Model (SCORM) aims to standardize electronic course content, its packaging and delivery. Instructional designers and e-learning material producer organizations accept SCORM?s significant impact on instructional design/delivery process, however not much known about how such standards will be implemented to…

  12. Computer programs for producing single-event aircraft noise data for specific engine power and meteorological conditions for use with USAF (United States Air Force) community noise model (NOISEMAP)

    NASA Astrophysics Data System (ADS)

    Mohlman, H. T.

    1983-04-01

    The Air Force community noise prediction model (NOISEMAP) is used to describe the aircraft noise exposure around airbases and thereby aid airbase planners to minimize exposure and prevent community encroachment which could limit mission effectiveness of the installation. This report documents two computer programs (OMEGA 10 and OMEGA 11) which were developed to prepare aircraft flight and ground runup noise data for input to NOISEMAP. OMEGA 10 is for flight operations and OMEGA 11 is for aircraft ground runups. All routines in each program are documented at a level useful to a programmer working with the code or a reader interested in a general overview of what happens within a specific subroutine. Both programs input normalized, reference aircraft noise data; i.e., data at a standard reference distance from the aircraft, for several fixed engine power settings, a reference airspeed and standard day meteorological conditions. Both programs operate on these normalized, reference data in accordance with user-defined, non-reference conditions to derive single-event noise data for 22 distances (200 to 25,000 feet) in a variety of physical and psycho-acoustic metrics. These outputs are in formats ready for input to NOISEMAP.

  13. Accuracy of Digital vs. Conventional Implant Impressions

    PubMed Central

    Lee, Sang J.; Betensky, Rebecca A.; Gianneschi, Grace E.; Gallucci, German O.

    2015-01-01

    The accuracy of digital impressions greatly influences the clinical viability in implant restorations. The aim of this study is to compare the accuracy of gypsum models acquired from the conventional implant impression to digitally milled models created from direct digitalization by three-dimensional analysis. Thirty gypsum and 30 digitally milled models impressed directly from a reference model were prepared. The models were scanned by a laboratory scanner and 30 STL datasets from each group were imported to an inspection software. The datasets were aligned to the reference dataset by a repeated best fit algorithm and 10 specified contact locations of interest were measured in mean volumetric deviations. The areas were pooled by cusps, fossae, interproximal contacts, horizontal and vertical axes of implant position and angulation. The pooled areas were statistically analysed by comparing each group to the reference model to investigate the mean volumetric deviations accounting for accuracy and standard deviations for precision. Milled models from digital impressions had comparable accuracy to gypsum models from conventional impressions. However, differences in fossae and vertical displacement of the implant position from the gypsum and digitally milled models compared to the reference model, exhibited statistical significance (p<0.001, p=0.020 respectively). PMID:24720423

  14. Tips on Creating Complex Geometry Using Solid Modeling Software

    ERIC Educational Resources Information Center

    Gow, George

    2008-01-01

    Three-dimensional computer-aided drafting (CAD) software, sometimes referred to as "solid modeling" software, is easy to learn, fun to use, and becoming the standard in industry. However, many users have difficulty creating complex geometry with the solid modeling software. And the problem is not entirely a student problem. Even some teachers and…

  15. Practised Intelligence Testing Based on a Modern Test Conceptualization and Its Reference to the Common Intelligence Theories

    ERIC Educational Resources Information Center

    Kubinger, Klaus D.; Litzenberger, Margarete; Mrakotsky, Christine

    2006-01-01

    The question is to what extent intelligence test-batteries prove any kind of empirical reference to common intelligence theories. Of particular interest are conceptualized tests that are of a high psychometric standard--those that fit the Rasch model--and hence are not exposed to fundamental critique. As individualized testing, i.e., a…

  16. [Application of traditional Chinese medicine reference standards in quality control of Chinese herbal pieces].

    PubMed

    Lu, Tu-Lin; Li, Jin-Ci; Yu, Jiang-Yong; Cai, Bao-Chang; Mao, Chun-Qin; Yin, Fang-Zhou

    2014-01-01

    Traditional Chinese medicine (TCM) reference standards plays an important role in the quality control of Chinese herbal pieces. This paper overviewed the development of TCM reference standards. By analyzing the 2010 edition of Chinese pharmacopoeia, the application of TCM reference standards in the quality control of Chinese herbal pieces was summarized, and the problems exiting in the system were put forward. In the process of improving the quality control level of Chinese herbal pieces, various kinds of advanced methods and technology should be used to research the characteristic reference standards of Chinese herbal pieces, more and more reasonable reference standards should be introduced in the quality control system of Chinese herbal pieces. This article discussed the solutions in the aspect of TCM reference standards, and future development of quality control on Chinese herbal pieces is prospected.

  17. International standards for monoclonal antibodies to support pre- and post-marketing product consistency: Evaluation of a candidate international standard for the bioactivities of rituximab.

    PubMed

    Prior, Sandra; Hufton, Simon E; Fox, Bernard; Dougall, Thomas; Rigsby, Peter; Bristow, Adrian

    2018-01-01

    The intrinsic complexity and heterogeneity of therapeutic monoclonal antibodies is built into the biosimilarity paradigm where critical quality attributes are controlled in exhaustive comparability studies with the reference medicinal product. The long-term success of biosimilars will depend on reassuring healthcare professionals and patients of consistent product quality, safety and efficacy. With this aim, the World Health Organization has endorsed the need for public bioactivity standards for therapeutic monoclonal antibodies in support of current controls. We have developed a candidate international potency standard for rituximab that was evaluated in a multi-center collaborative study using participants' own qualified Fc-effector function and cell-based binding bioassays. Dose-response curve model parameters were shown to reflect similar behavior amongst rituximab preparations, albeit with some differences in potency. In the absence of a common reference standard, potency estimates were in poor agreement amongst laboratories, but the use of the candidate preparation significantly reduced this variability. Our results suggest that the candidate rituximab standard can support bioassay performance and improve data harmonization, which when implemented will promote consistency of rituximab products over their life-cycles. This data provides the first scientific evidence that a classical standardization exercise allowing traceability of bioassay data to an international standard is also applicable to rituximab. However, we submit that this new type of international standard needs to be used appropriately and its role not to be mistaken with that of the reference medicinal product.

  18. New Dental Accreditation Standard on Critical Thinking: A Call for Learning Models, Outcomes, Assessments.

    PubMed

    Johnsen, David C; Williams, John N; Baughman, Pauletta Gay; Roesch, Darren M; Feldman, Cecile A

    2015-10-01

    This opinion article applauds the recent introduction of a new dental accreditation standard addressing critical thinking and problem-solving, but expresses a need for additional means for dental schools to demonstrate they are meeting the new standard because articulated outcomes, learning models, and assessments of competence are still being developed. Validated, research-based learning models are needed to define reference points against which schools can design and assess the education they provide to their students. This article presents one possible learning model for this purpose and calls for national experts from within and outside dental education to develop models that will help schools define outcomes and assess performance in educating their students to become practitioners who are effective critical thinkers and problem-solvers.

  19. Lithium in halo stars from standard stellar evolution

    NASA Technical Reports Server (NTRS)

    Deliyannis, Constantine P.; Demarque, Pierre; Kawaler, Steven D.

    1990-01-01

    A grid has been constructed of theoretical evolution sequences of models for low-metallicity stars from the premain-sequence to the giant branch phases. The grid is used to study the history of surface Li abundance during standard stellar evolution. The Li-7 observations of halo stars by Spite and Spite (1982) and subsequent observations are synthesized to separate the halo stars by age. The theory of surface Li abundance is illustrated by following the evolution of a reference halo star model from the contracting fully convective premain sequence to the giant branch phase. The theoretical models are compared with observed Li abundances. The results show that the halo star lithium abundances can be explained in the context of standard stellar evolution theory using completely standard assumptions and physics.

  20. Part 2: Sensitivity comparisons of the insect Centroptilum triangulifer to Ceriodaphnia dubia and Daphnia magna using standard reference toxicants; NaCl, KCl and CuSO4

    EPA Science Inventory

    Criteria for establishing water quality standards that are protective of all native biota are generally based upon laboratory toxicity tests. These test utilize common model organisms that have established test methods. However, only a small portion of species have established ...

  1. 24 CFR 200.925c - Model codes.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... DEVELOPMENT GENERAL INTRODUCTION TO FHA PROGRAMS Minimum Property Standards § 200.925c Model codes. (a... Plumbing Code, 1993 Edition, and the BOCA National Mechanical Code, 1993 Edition, excluding Chapter I, Administration, for the Building, Plumbing and Mechanical Codes and the references to fire retardant treated wood...

  2. 24 CFR 200.925c - Model codes.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... DEVELOPMENT GENERAL INTRODUCTION TO FHA PROGRAMS Minimum Property Standards § 200.925c Model codes. (a... Plumbing Code, 1993 Edition, and the BOCA National Mechanical Code, 1993 Edition, excluding Chapter I, Administration, for the Building, Plumbing and Mechanical Codes and the references to fire retardant treated wood...

  3. Metrological approaches to organic chemical purity: primary reference materials for vitamin D metabolites.

    PubMed

    Nelson, Michael A; Bedner, Mary; Lang, Brian E; Toman, Blaza; Lippa, Katrice A

    2015-11-01

    Given the critical role of pure, organic compound primary reference standards used to characterize and certify chemical Certified Reference Materials (CRMs), it is essential that associated mass purity assessments be fit-for-purpose, represented by an appropriate uncertainty interval, and metrologically sound. The mass fraction purities (% g/g) of 25-hydroxyvitamin D (25(OH)D) reference standards used to produce and certify values for clinical vitamin D metabolite CRMs were investigated by multiple orthogonal quantitative measurement techniques. Quantitative (1)H-nuclear magnetic resonance spectroscopy (qNMR) was performed to establish traceability of these materials to the International System of Units (SI) and to directly assess the principal analyte species. The 25(OH)D standards contained volatile and water impurities, as well as structurally-related impurities that are difficult to observe by chromatographic methods or to distinguish from the principal 25(OH)D species by one-dimensional NMR. These impurities have the potential to introduce significant biases to purity investigations in which a limited number of measurands are quantified. Combining complementary information from multiple analytical methods, using both direct and indirect measurement techniques, enabled mitigation of these biases. Purities of 25(OH)D reference standards and associated uncertainties were determined using frequentist and Bayesian statistical models to combine data acquired via qNMR, liquid chromatography with UV absorbance and atmospheric pressure-chemical ionization mass spectrometric detection (LC-UV, LC-ACPI-MS), thermogravimetric analysis (TGA), and Karl Fischer (KF) titration.

  4. Reference aquaplanet climate in the Community Atmosphere Model, Version 5

    DOE PAGES

    Medeiros, Brian; Williamson, David L.; Olson, Jerry G.

    2016-03-18

    In this study, fundamental characteristics of the aquaplanet climate simulated by the Community Atmosphere Model, Version 5.3 (CAM5.3) are presented. The assumptions and simplifications of the configuration are described. A 16 year long, perpetual equinox integration with prescribed SST using the model’s standard 18 grid spacing is presented as a reference simulation. Statistical analysis is presented that shows similar aquaplanet configurations can be run for about 2 years to obtain robust climatological structures, including global and zonal means, eddy statistics, and precipitation distributions. Such a simulation can be compared to the reference simulation to discern differences in the climate, includingmore » an assessment of confidence in the differences. To aid such comparisons, the reference simulation has been made available via earthsystemgrid.org. Examples are shown comparing the reference simulation with simulations from the CAM5 series that make different microphysical assumptions and use a different dynamical core.« less

  5. Promoting A-Priori Interoperability of HLA-Based Simulations in the Space Domain: The SISO Space Reference FOM Initiative

    NASA Technical Reports Server (NTRS)

    Moller, Bjorn; Garro, Alfredo; Falcone, Alberto; Crues, Edwin Z.; Dexter, Daniel E.

    2016-01-01

    Distributed and Real-Time Simulation plays a key-role in the Space domain being exploited for missions and systems analysis and engineering as well as for crew training and operational support. One of the most popular standards is the 1516-2010 IEEE Standard for Modeling and Simulation (M&S) High Level Architecture (HLA). HLA supports the implementation of distributed simulations (called Federations) in which a set of simulation entities (called Federates) can interact using a Run-Time Infrastructure (RTI). In a given Federation, a Federate can publish and/or subscribes objects and interactions on the RTI only in accordance with their structures as defined in a FOM (Federation Object Model). Currently, the Space domain is characterized by a set of incompatible FOMs that, although meet the specific needs of different organizations and projects, increases the long-term cost for interoperability. In this context, the availability of a reference FOM for the Space domain will enable the development of interoperable HLA-based simulators for related joint projects and collaborations among worldwide organizations involved in the Space domain (e.g. NASA, ESA, Roscosmos, and JAXA). The paper presents a first set of results achieved by a SISO standardization effort that aims at providing a Space Reference FOM for international collaboration on Space systems simulations.

  6. A SCORM Odyssey.

    ERIC Educational Resources Information Center

    Shackelford, Bill

    2002-01-01

    Discusses the Shareable Content Object Reference Model (SCORM), which integrates electronic learning standards to provide a common ground for course development. Describes the Advanced Distributed Learning Co-Laboratory at the University of Wisconsin- Madison campus. (JOW)

  7. Training the Front-Line Union Man

    ERIC Educational Resources Information Center

    Heier, W. D.

    1970-01-01

    A study report and recommendations for training shop stewards, with particular reference to the need for fuller cooperation between unions and management in program planning. A standardized union steward job model is included. (LY)

  8. A process-based standard for the Solar Energetic Particle Event Environment

    NASA Astrophysics Data System (ADS)

    Gabriel, Stephen

    For 10 years or more, there has been a lack of concensus on what the ISO standard model for the Solar Energetic Particle Event (SEPE) environment should be. Despite many technical discussions between the world experts in this field, it has been impossible to agree on which of the several models available should be selected as the standard. Most of these discussions at the ISO WG4 meetings and conferences, etc have centred around the differences in modelling approach between the MSU model and the several remaining models from elsewhere worldwide (mainly the USA and Europe). The topic is considered timely given the inclusion of a session on reference data sets at the Space Weather Workshop in Boulder in April 2014. The original idea of a ‘process-based’ standard was conceived by Dr Kent Tobiska as a way of getting round the problems associated with not only the presence of different models, which in themselves could have quite distinct modelling approaches but could also be based on different data sets. In essence, a process based standard approach overcomes these issues by allowing there to be more than one model and not necessarily a single standard model; however, any such model has to be completely transparent in that the data set and the modelling techniques used have to be not only to be clearly and unambiguously defined but also subject to peer review. If the model meets all of these requirements then it should be acceptable as a standard model. So how does this process-based approach resolve the differences between the existing modelling approaches for the SEPE environment and remove the impasse? In a sense, it does not remove all of the differences but only some of them; however, most importantly it will allow something which so far has been impossible without ambiguities and disagreement and that is a comparison of the results of the various models. To date one of the problems (if not the major one) in comparing the results of the various different SEPE statistical models has been caused by two things: 1) the data set and 2) the definition of an event Because unravelling the dependencies of the outputs of different statistical models on these two parameters is extremely difficult if not impossible, currently comparison of the results from the different models is also extremely difficult and can lead to controversies, especially over which model is the correct one; hence, when it comes to using these models for engineering purposes to calculate, for example, the radiation dose for a particular mission, the user, who is in all likelihood not an expert in this field, could be given two( or even more) very different environments and find it impossible to know how to select one ( or even how to compare them). What is proposed then, is a process-based standard, which in common with nearly all of the current models is composed of 3 elements, a standard data set, a standard event definition and a resulting standard event list. A standard event list is the output of this standard and can then be used with any of the existing (or indeed future) models that are based on events. This standard event list is completely traceable and transparent and represents a reference event list for all the community. When coupled with a statistical model, the results when compared will only be dependent on the statistical model and not on the data set or event definition.

  9. Estimation of the upper bound of predictive performance for alternative models that use in vivo reference data (OpenTox USA 2017)

    EPA Science Inventory

    The number of chemicals with limited toxicological information for chemical safety decision-making has accelerated alternative model development, which often are evaluated via referencing animal toxicology studies. In vivo studies are generally considered the standard for hazard ...

  10. Modeling Nuclear Decay: A Point of Integration between Chemistry and Mathematics.

    ERIC Educational Resources Information Center

    Crippen, Kent J.; Curtright, Robert D.

    1998-01-01

    Describes four activities that use graphing calculators to model nuclear-decay phenomena. Students ultimately develop a notion about the radioactive waste produced by nuclear fission. These activities are in line with national educational standards and allow for the integration of science and mathematics. Contains 13 references. (Author/WRM)

  11. Global Reference Atmosphere Model (GRAM)

    NASA Technical Reports Server (NTRS)

    Johnson, D. L.; Blocker, Rhonda; Justus, C. G.

    1993-01-01

    4D model provides atmospheric parameter values either automatically at positions along linear path or along any set of connected positions specified by user. Based on actual data, GRAM provides thermal wind shear for monthly mean winds, percent deviation from standard atmosphere, mean vertical wind, and perturbation data for each position.

  12. Added value of cost-utility analysis in simple diagnostic studies of accuracy: (18)F-fluoromethylcholine PET/CT in prostate cancer staging.

    PubMed

    Gerke, Oke; Poulsen, Mads H; Høilund-Carlsen, Poul Flemming

    2015-01-01

    Diagnostic studies of accuracy targeting sensitivity and specificity are commonly done in a paired design in which all modalities are applied in each patient, whereas cost-effectiveness and cost-utility analyses are usually assessed either directly alongside to or indirectly by means of stochastic modeling based on larger randomized controlled trials (RCTs). However the conduct of RCTs is hampered in an environment such as ours, in which technology is rapidly evolving. As such, there is a relatively limited number of RCTs. Therefore, we investigated as to which extent paired diagnostic studies of accuracy can be also used to shed light on economic implications when considering a new diagnostic test. We propose a simple decision tree model-based cost-utility analysis of a diagnostic test when compared to the current standard procedure and exemplify this approach with published data from lymph node staging of prostate cancer. Average procedure costs were taken from the Danish Diagnosis Related Groups Tariff in 2013 and life expectancy was estimated for an ideal 60 year old patient based on prostate cancer stage and prostatectomy or radiation and chemotherapy. Quality-adjusted life-years (QALYs) were deduced from the literature, and an incremental cost-effectiveness ratio (ICER) was used to compare lymph node dissection with respective histopathological examination (reference standard) and (18)F-fluoromethylcholine positron emission tomography/computed tomography (FCH-PET/CT). Lower bounds of sensitivity and specificity of FCH-PET/CT were established at which the replacement of the reference standard by FCH-PET/CT comes with a trade-off between worse effectiveness and lower costs. Compared to the reference standard in a diagnostic accuracy study, any imperfections in accuracy of a diagnostic test imply that replacing the reference standard generates a loss in effectiveness and utility. We conclude that diagnostic studies of accuracy can be put to a more extensive use, over and above a mere indication of sensitivity and specificity of an imaging test, and that health economic considerations should be undertaken when planning a prospective diagnostic accuracy study. These endeavors will prove especially fruitful when comparing several imaging techniques with one another, or the same imaging technique using different tracers, with an independent reference standard for the evaluation of results.

  13. Detailed clinical models: representing knowledge, data and semantics in healthcare information technology.

    PubMed

    Goossen, William T F

    2014-07-01

    This paper will present an overview of the developmental effort in harmonizing clinical knowledge modeling using the Detailed Clinical Models (DCMs), and will explain how it can contribute to the preservation of Electronic Health Records (EHR) data. Clinical knowledge modeling is vital for the management and preservation of EHR and data. Such modeling provides common data elements and terminology binding with the intention of capturing and managing clinical information over time and location independent from technology. Any EHR data exchange without an agreed clinical knowledge modeling will potentially result in loss of information. Many attempts exist from the past to model clinical knowledge for the benefits of semantic interoperability using standardized data representation and common terminologies. The objective of each project is similar with respect to consistent representation of clinical data, using standardized terminologies, and an overall logical approach. However, the conceptual, logical, and the technical expressions are quite different in one clinical knowledge modeling approach versus another. There currently are synergies under the Clinical Information Modeling Initiative (CIMI) in order to create a harmonized reference model for clinical knowledge models. The goal for the CIMI is to create a reference model and formalisms based on for instance the DCM (ISO/TS 13972), among other work. A global repository of DCMs may potentially be established in the future.

  14. Defining Chlorophyll-a Reference Conditions in European Lakes

    PubMed Central

    Alves, Maria Helena; Argillier, Christine; van den Berg, Marcel; Buzzi, Fabio; Hoehn, Eberhard; de Hoyos, Caridad; Karottki, Ivan; Laplace-Treyture, Christophe; Solheim, Anne Lyche; Ortiz-Casas, José; Ott, Ingmar; Phillips, Geoff; Pilke, Ansa; Pádua, João; Remec-Rekar, Spela; Riedmüller, Ursula; Schaumburg, Jochen; Serrano, Maria Luisa; Soszka, Hanna; Tierney, Deirdre; Urbanič, Gorazd; Wolfram, Georg

    2010-01-01

    The concept of “reference conditions” describes the benchmark against which current conditions are compared when assessing the status of water bodies. In this paper we focus on the establishment of reference conditions for European lakes according to a phytoplankton biomass indicator—the concentration of chlorophyll-a. A mostly spatial approach (selection of existing lakes with no or minor human impact) was used to set the reference conditions for chlorophyll-a values, supplemented by historical data, paleolimnological investigations and modelling. The work resulted in definition of reference conditions and the boundary between “high” and “good” status for 15 main lake types and five ecoregions of Europe: Alpine, Atlantic, Central/Baltic, Mediterranean, and Northern. Additionally, empirical models were developed for estimating site-specific reference chlorophyll-a concentrations from a set of potential predictor variables. The results were recently formulated into the EU legislation, marking the first attempt in international water policy to move from chemical quality standards to ecological quality targets. PMID:20401659

  15. The international growth standard for preadolescent and adolescent children: statistical considerations.

    PubMed

    Cole, T J

    2006-12-01

    This article discusses statistical considerations for the design of a new study intended to provide an International Growth Standard for Preadolescent and Adolescent Children, including issues such as cross-sectional, longitudinal, and mixed designs; sample-size derivation for the number of populations and number of children per population; modeling of growth centiles of height, weight, and other measurements; and modeling of the adolescent growth spurt. The conclusions are that a mixed longitudinal design will provide information on both growth distance and velocity; samples of children from 5 to 10 sites should be suitable for an international standard (based on political rather than statistical arguments); the samples should be broadly uniform across age but oversampled during puberty, and should include data into adulthood. The LMS method is recommended for constructing measurement centiles, and parametric or semiparametric approaches are available to estimate the timing of the adolescent growth spurt in individuals. If the new standard is to be grafted onto the 2006 World Health Organization (WHO) reference, caution is needed at the join point of 5 years, where children from the new standard are likely to be appreciably more obese than those from the WHO reference, due to the rising trends in obesity and the time gap in data collection between the two surveys.

  16. Eddy-Current Reference Standard

    NASA Technical Reports Server (NTRS)

    Ambrose, H. H., Jr.

    1985-01-01

    Magnetic properties of metallic reference standards duplicated and stabilized for eddy-current coil measurements over long times. Concept uses precisely machined notched samples of known annealed materials as reference standards.

  17. Rabies vaccine standards: comparison of the 5th and 6th WHO international reference standards to the USDA veterinary reference standard.

    PubMed

    Hermann, J; Fry, A; Reising, M; Patterson, P; Siev, D; Gatewood, D

    2012-11-06

    Ensuring rabies vaccines are potent and effective is paramount in preventing transmission of this deadly disease and safeguarding public health. Efficacy of human and veterinary vaccines is ensured by evaluating relative potency estimates of the vaccine compared to a rabies reference standard using the National Institutes of Health (NIH) test. Reference vaccines are based on the International Standard for Rabies Vaccine provided by the World Health Organization (WHO). A comparison study was conducted to determine the relative potency of the 5th WHO, 6th WHO, and United States Department of Agriculture's (USDA) 08-14 reference standards using the NIH test. Results from the study demonstrate that the 6th WHO reference standard is approximately twice as potent as the 5th WHO reference when reconstituted to contain 1 IU per ml. Based on these results, the Center for Veterinary Biologics (CVB) doubled the reconstitution volume of USDA veterinary reference 08-14 from 13 ml to 26 ml, for an initial use dilution of 0.7 IU per ml for use by veterinary biologics manufacturers in the NIH test. This study emphasizes the importance of reference standard calibration for use in the National Institutes of Health test. Published by Elsevier Ltd.

  18. Direct calibration of a reference standard against the air kerma strength primary standard, at 192Ir HDR energy.

    PubMed

    Rajan, K N Govinda; Selvam, T Palani; Bhatt, B C; Vijayam, M; Patki, V S; Vinatha; Pendse, A M; Kannan, V

    2002-04-07

    The primary standard of low air kerma rate sources or beams, maintained at the Radiological Standards Laboratory (RSL) of the Bhabha Atomic Research Centre (BARC), is a 60 cm3 spherical graphite ionization chamber. A 192Ir HDR source was standardized at the hospital site in units of air kerma strength (AKS) using this primary standard. A 400 cm3 bakelite chamber, functioning as a reference standard at the RSL for a long period, at low air kerma rates (compared to external beam dose rates), was calibrated against the primary standard. It was seen that the primary standard and the reference standard, both being of low Z, showed roughly the same scatter response and yielded the same calibration factor for the 400 cm3 reference chamber, with or without room scatter. However, any likelihood of change in the reference chamber calibration factor would necessitate the re-transport of the primary standard to the hospital site for re-calibration. Frequent transport of the primary standard can affect the long-term stability of the primary standard, due to its movement or other extraneous causes. The calibration of the reference standard against the primary standard at the RSL, for an industrial type 192Ir source maintained at the laboratory, showed excellent agreement with the hospital calibration, making it possible to check the reference chamber calibration at RSL itself. Further calibration procedures have been developed to offer traceable calibration of the hospital well ionization chambers.

  19. Local network assessment

    NASA Astrophysics Data System (ADS)

    Glen, D. V.

    1985-04-01

    Local networks, related standards activities of the Institute of Electrical and Electronics Engineers the American National Standards Institute and other elements are presented. These elements include: (1) technology choices such as topology, transmission media, and access protocols; (2) descriptions of standards for the 802 local area networks (LAN's); high speed local networks (HSLN's) and military specification local networks; and (3) intra- and internetworking using bridges and gateways with protocols Interconnection (OSI) reference model. The convergence of LAN/PBX technology is also described.

  20. Development and Evaluation of Reference Standards for Image-based Telemedicine Diagnosis and Clinical Research Studies in Ophthalmology

    PubMed Central

    Ryan, Michael C.; Ostmo, Susan; Jonas, Karyn; Berrocal, Audina; Drenser, Kimberly; Horowitz, Jason; Lee, Thomas C.; Simmons, Charles; Martinez-Castellanos, Maria-Ana; Chan, R.V. Paul; Chiang, Michael F.

    2014-01-01

    Information systems managing image-based data for telemedicine or clinical research applications require a reference standard representing the correct diagnosis. Accurate reference standards are difficult to establish because of imperfect agreement among physicians, and discrepancies between clinical vs. image-based diagnosis. This study is designed to describe the development and evaluation of reference standards for image-based diagnosis, which combine diagnostic impressions of multiple image readers with the actual clinical diagnoses. We show that agreement between image reading and clinical examinations was imperfect (689 [32%] discrepancies in 2148 image readings), as was inter-reader agreement (kappa 0.490-0.652). This was improved by establishing an image-based reference standard defined as the majority diagnosis given by three readers (13% discrepancies with image readers). It was further improved by establishing an overall reference standard that incorporated the clinical diagnosis (10% discrepancies with image readers). These principles of establishing reference standards may be applied to improve robustness of real-world systems supporting image-based diagnosis. PMID:25954463

  1. International standards for monoclonal antibodies to support pre- and post-marketing product consistency: Evaluation of a candidate international standard for the bioactivities of rituximab

    PubMed Central

    Prior, Sandra; Hufton, Simon E.; Dougall, Thomas; Rigsby, Peter; Bristow, Adrian

    2018-01-01

    ABSTRACT The intrinsic complexity and heterogeneity of therapeutic monoclonal antibodies is built into the biosimilarity paradigm where critical quality attributes are controlled in exhaustive comparability studies with the reference medicinal product. The long-term success of biosimilars will depend on reassuring healthcare professionals and patients of consistent product quality, safety and efficacy. With this aim, the World Health Organization has endorsed the need for public bioactivity standards for therapeutic monoclonal antibodies in support of current controls. We have developed a candidate international potency standard for rituximab that was evaluated in a multi-center collaborative study using participants' own qualified Fc-effector function and cell-based binding bioassays. Dose-response curve model parameters were shown to reflect similar behavior amongst rituximab preparations, albeit with some differences in potency. In the absence of a common reference standard, potency estimates were in poor agreement amongst laboratories, but the use of the candidate preparation significantly reduced this variability. Our results suggest that the candidate rituximab standard can support bioassay performance and improve data harmonization, which when implemented will promote consistency of rituximab products over their life-cycles. This data provides the first scientific evidence that a classical standardization exercise allowing traceability of bioassay data to an international standard is also applicable to rituximab. However, we submit that this new type of international standard needs to be used appropriately and its role not to be mistaken with that of the reference medicinal product. PMID:28985159

  2. Building a semantic web-based metadata repository for facilitating detailed clinical modeling in cancer genome studies.

    PubMed

    Sharma, Deepak K; Solbrig, Harold R; Tao, Cui; Weng, Chunhua; Chute, Christopher G; Jiang, Guoqian

    2017-06-05

    Detailed Clinical Models (DCMs) have been regarded as the basis for retaining computable meaning when data are exchanged between heterogeneous computer systems. To better support clinical cancer data capturing and reporting, there is an emerging need to develop informatics solutions for standards-based clinical models in cancer study domains. The objective of the study is to develop and evaluate a cancer genome study metadata management system that serves as a key infrastructure in supporting clinical information modeling in cancer genome study domains. We leveraged a Semantic Web-based metadata repository enhanced with both ISO11179 metadata standard and Clinical Information Modeling Initiative (CIMI) Reference Model. We used the common data elements (CDEs) defined in The Cancer Genome Atlas (TCGA) data dictionary, and extracted the metadata of the CDEs using the NCI Cancer Data Standards Repository (caDSR) CDE dataset rendered in the Resource Description Framework (RDF). The ITEM/ITEM_GROUP pattern defined in the latest CIMI Reference Model is used to represent reusable model elements (mini-Archetypes). We produced a metadata repository with 38 clinical cancer genome study domains, comprising a rich collection of mini-Archetype pattern instances. We performed a case study of the domain "clinical pharmaceutical" in the TCGA data dictionary and demonstrated enriched data elements in the metadata repository are very useful in support of building detailed clinical models. Our informatics approach leveraging Semantic Web technologies provides an effective way to build a CIMI-compliant metadata repository that would facilitate the detailed clinical modeling to support use cases beyond TCGA in clinical cancer study domains.

  3. Analyses on hydrophobicity and attractiveness of all-atom distance-dependent potentials

    PubMed Central

    Shirota, Matsuyuki; Ishida, Takashi; Kinoshita, Kengo

    2009-01-01

    Accurate model evaluation is a crucial step in protein structure prediction. For this purpose, statistical potentials, which evaluate a model structure based on the observed atomic distance frequencies in comparison with those in reference states, have been widely used. The reference state is a virtual state where all of the atomic interactions are turned off, and it provides a standard to measure the observed frequencies. In this study, we examined seven all-atom distance-dependent potentials with different reference states. As results, we observed that the variations of atom pair composition and those of distance distributions in the reference states produced systematic changes in the hydrophobic and attractive characteristics of the potentials. The performance evaluations with the CASP7 structures indicated that the preference of hydrophobic interactions improved the correlation between the energy and the GDT-TS score, but decreased the Z-score of the native structure. The attractiveness of potential improved both the correlation and Z-score for template-based modeling targets, but the benefit was smaller in free modeling targets. These results indicated that the performances of the potentials were more strongly influenced by their characteristics than by the accuracy of the definitions of the reference states. PMID:19588493

  4. Support time-dependent transformations for surveying and GIS : current status and upcoming challenges

    NASA Astrophysics Data System (ADS)

    Mahmoudabadi, H.; Lercier, D.; Vielliard, S.; Mein, N.; Briggs, G.

    2016-12-01

    The support of time-dependent transformations for surveying and GIS is becoming a critical issue. We need to convert positions from the realizations of the International Terrestrial Reference Frame to any national reference frame. This problem is easy to solve when all of the required information is available. But it becomes really complicated in a worldwide context. We propose an overview of the current ITRF-aligned reference frames and we describe a global solution to support time-dependent transformations between them and the International Terrestrial Reference Frame. We focus on the uncertainties of station velocities used. In a first approximation, we use a global tectonic plate model to calculate point velocities. We show the impact of the velocity model on the coordinate accuracies. Several countries, particularly in active regions, are developing semi-dynamic reference frames. These frames include local displacement models updated regularly and/or after major events (such as earthquakes). Their integration into surveying or GIS applications is an upcoming challenge. We want to encourage the geodetic community to develop and use standard formats.

  5. 15 CFR 200.105 - Standard reference data.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ..., PROCEDURES, AND FEES § 200.105 Standard reference data. Data on the physical and chemical properties of the... application in research, development, engineering design, and commerce. The Office of Standard Reference Data... Physical and Chemical Reference Data, published jointly with the American Chemical Society and the American...

  6. 15 CFR 200.105 - Standard reference data.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ..., PROCEDURES, AND FEES § 200.105 Standard reference data. Data on the physical and chemical properties of the... application in research, development, engineering design, and commerce. The Office of Standard Reference Data... Physical and Chemical Reference Data, published jointly with the American Chemical Society and the American...

  7. 15 CFR 200.105 - Standard reference data.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ..., PROCEDURES, AND FEES § 200.105 Standard reference data. Data on the physical and chemical properties of the... application in research, development, engineering design, and commerce. The Office of Standard Reference Data... Physical and Chemical Reference Data, published jointly with the American Chemical Society and the American...

  8. 15 CFR 200.105 - Standard reference data.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ..., PROCEDURES, AND FEES § 200.105 Standard reference data. Data on the physical and chemical properties of the... application in research, development, engineering design, and commerce. The Office of Standard Reference Data... Physical and Chemical Reference Data, published jointly with the American Chemical Society and the American...

  9. Simplified estimation of age-specific reference intervals for skewed data.

    PubMed

    Wright, E M; Royston, P

    1997-12-30

    Age-specific reference intervals are commonly used in medical screening and clinical practice, where interest lies in the detection of extreme values. Many different statistical approaches have been published on this topic. The advantages of a parametric method are that they necessarily produce smooth centile curves, the entire density is estimated and an explicit formula is available for the centiles. The method proposed here is a simplified version of a recent approach proposed by Royston and Wright. Basic transformations of the data and multiple regression techniques are combined to model the mean, standard deviation and skewness. Using these simple tools, which are implemented in almost all statistical computer packages, age-specific reference intervals may be obtained. The scope of the method is illustrated by fitting models to several real data sets and assessing each model using goodness-of-fit techniques.

  10. Use of Bayesian Inference in Crystallographic Structure Refinement via Full Diffraction Profile Analysis

    PubMed Central

    Fancher, Chris M.; Han, Zhen; Levin, Igor; Page, Katharine; Reich, Brian J.; Smith, Ralph C.; Wilson, Alyson G.; Jones, Jacob L.

    2016-01-01

    A Bayesian inference method for refining crystallographic structures is presented. The distribution of model parameters is stochastically sampled using Markov chain Monte Carlo. Posterior probability distributions are constructed for all model parameters to properly quantify uncertainty by appropriately modeling the heteroskedasticity and correlation of the error structure. The proposed method is demonstrated by analyzing a National Institute of Standards and Technology silicon standard reference material. The results obtained by Bayesian inference are compared with those determined by Rietveld refinement. Posterior probability distributions of model parameters provide both estimates and uncertainties. The new method better estimates the true uncertainties in the model as compared to the Rietveld method. PMID:27550221

  11. Growth references for Tsimane forager-horticulturalists of the Bolivian Amazon

    PubMed Central

    Blackwell, Aaron D.; Urlacher, Samuel S.; Beheim, Bret; von Rueden, Christopher; Jaeggi, Adrian; Stieglitz, Jonathan; Trumble, Benjamin C.; Gurven, Michael; Kaplan, Hillard

    2016-01-01

    Objectives Growth standards and references currently used to assess population and individual health are derived primarily from urban populations, including few individuals from indigenous or subsistence groups. Given environmental and genetic differences, growth may vary in these populations. Thus, there is a need to assess whether international standards are appropriate for all populations, and to produce population specific references if growth differs. Here we present and assess growth references for the Tsimane, an indigenous population of Bolivian forager-horticulturalists. Methods Mixed cross-sectional/longitudinal anthropometrics (9,614 individuals; 30,118 observations; ages 0–29 years) were used to generate centile curves and Lambda-Mu-Sigma (LMS) tables for height-for-age, weight-for-age, body mass index (BMI)-for-age, and weight-for-height (WFH) using Generalized Additive Models for Location Shape and Scale (GAMLSS). Velocity curves were generated using SuperImposition by Translation and Rotation (SITAR). Tsimane ≤5 years were compared World Health Organization (WHO) standards while those >5 years were compared to WHO school age references. All ages were compared to published references for Shuar forager-horticulturalists of the Ecuadorian Amazon. Results Tsimane growth differs from WHO values in height and weight, but is similar for BMI and WFH. Tsimane growth is characterized by slow height velocity in childhood and early adolescent peak height velocity at 11.3 and 13.2 years for girls and boys. Tsimane growth patterns are similar to Shuar, suggesting shared features of growth among indigenous South Americans. Conclusions International references for BMI-for-age and WFH are likely appropriate for Tsimane, but differences in height-for-age and weight-for-age suggest Tsimane specific references may be useful for these measures. PMID:28218400

  12. Growth references for Tsimane forager-horticulturalists of the Bolivian Amazon.

    PubMed

    Blackwell, Aaron D; Urlacher, Samuel S; Beheim, Bret; von Rueden, Christopher; Jaeggi, Adrian; Stieglitz, Jonathan; Trumble, Benjamin C; Gurven, Michael; Kaplan, Hillard

    2017-03-01

    Growth standards and references currently used to assess population and individual health are derived primarily from urban populations, including few individuals from indigenous or subsistence groups. Given environmental and genetic differences, growth may vary in these populations. Thus, there is a need to assess whether international standards are appropriate for all populations, and to produce population specific references if growth differs. Here we present and assess growth references for the Tsimane, an indigenous population of Bolivian forager-horticulturalists. Mixed cross-sectional/longitudinal anthropometrics (9,614 individuals; 30,118 observations; ages 0-29 years) were used to generate centile curves and Lambda-Mu-Sigma (LMS) tables for height-for-age, weight-for-age, body mass index (BMI)-for-age, and weight-for-height (WFH) using Generalized Additive Models for Location Shape and Scale (GAMLSS). Velocity curves were generated using SuperImposition by Translation and Rotation (SITAR). Tsimane ≤5 years were compared to World Health Organization (WHO) standards while those >5 years were compared to WHO school age references. All ages were compared to published references for Shuar forager-horticulturalists of the Ecuadorian Amazon. Tsimane growth differs from WHO values in height and weight, but is similar for BMI and WFH. Tsimane growth is characterized by slow height velocity in childhood and early adolescent peak height velocity at 11.3 and 13.2 years for girls and boys. Tsimane growth patterns are similar to Shuar, suggesting shared features of growth among indigenous South Americans. International references for BMI-for-age and WFH are likely appropriate for Tsimane, but differences in height-for-age and weight-for-age suggest Tsimane specific references may be useful for these measures. © 2016 Wiley Periodicals, Inc.

  13. 3D Reconstruction and Standardization of the Rat Vibrissal Cortex for Precise Registration of Single Neuron Morphology

    PubMed Central

    Egger, Robert; Narayanan, Rajeevan T.; Helmstaedter, Moritz; de Kock, Christiaan P. J.; Oberlaender, Marcel

    2012-01-01

    The three-dimensional (3D) structure of neural circuits is commonly studied by reconstructing individual or small groups of neurons in separate preparations. Investigation of structural organization principles or quantification of dendritic and axonal innervation thus requires integration of many reconstructed morphologies into a common reference frame. Here we present a standardized 3D model of the rat vibrissal cortex and introduce an automated registration tool that allows for precise placement of single neuron reconstructions. We (1) developed an automated image processing pipeline to reconstruct 3D anatomical landmarks, i.e., the barrels in Layer 4, the pia and white matter surfaces and the blood vessel pattern from high-resolution images, (2) quantified these landmarks in 12 different rats, (3) generated an average 3D model of the vibrissal cortex and (4) used rigid transformations and stepwise linear scaling to register 94 neuron morphologies, reconstructed from in vivo stainings, to the standardized cortex model. We find that anatomical landmarks vary substantially across the vibrissal cortex within an individual rat. In contrast, the 3D layout of the entire vibrissal cortex remains remarkably preserved across animals. This allows for precise registration of individual neuron reconstructions with approximately 30 µm accuracy. Our approach could be used to reconstruct and standardize other anatomically defined brain areas and may ultimately lead to a precise digital reference atlas of the rat brain. PMID:23284282

  14. Reference Standard Test and the Diagnostic Ability of Spectral Domain Optical Coherence Tomography in Glaucoma.

    PubMed

    Rao, Harsha L; Yadav, Ravi K; Addepalli, Uday K; Begum, Viquar U; Senthil, Sirisha; Choudhari, Nikhil S; Garudadri, Chandra S

    2015-08-01

    To evaluate the relationship between the reference standard used to diagnose glaucoma and the diagnostic ability of spectral domain optical coherence tomograph (SDOCT). In a cross-sectional study, 280 eyes of 175 consecutive subjects, referred to a tertiary eye care center for glaucoma evaluation, underwent optic disc photography, visual field (VF) examination, and SDOCT examination. The cohort was divided into glaucoma and control groups based on 3 reference standards for glaucoma diagnosis: first based on the optic disc classification (179 glaucoma and 101 control eyes), second on VF classification (glaucoma hemifield test outside normal limits and pattern SD with P-value of <5%, 130 glaucoma and 150 control eyes), and third on the presence of both glaucomatous optic disc and glaucomatous VF (125 glaucoma and 155 control eyes). Relationship between the reference standards and the diagnostic parameters of SDOCT were evaluated using areas under the receiver operating characteristic curve, sensitivity, and specificity. Areas under the receiver operating characteristic curve and sensitivities of most of the SDOCT parameters obtained with the 3 reference standards (ranging from 0.74 to 0.88 and 72% to 88%, respectively) were comparable (P>0.05). However, specificities of SDOCT parameters were significantly greater (P<0.05) with optic disc classification as reference standard (74% to 88%) compared with VF classification as reference standard (57% to 74%). Diagnostic parameters of SDOCT that was significantly affected by reference standard was the specificity, which was greater with optic disc classification as the reference standard. This has to be considered when comparing the diagnostic ability of SDOCT across studies.

  15. The Benefits and Future of Standards: Metadata and Beyond

    NASA Astrophysics Data System (ADS)

    Stracke, Christian M.

    This article discusses the benefits and future of standards and presents the generic multi-dimensional Reference Model. First the importance and the tasks of interoperability as well as quality development and their relationship are analyzed. Especially in e-Learning their connection and interdependence is evident: Interoperability is one basic requirement for quality development. In this paper, it is shown how standards and specifications are supporting these crucial issues. The upcoming ISO metadata standard MLR (Metadata for Learning Resource) will be introduced and used as example for identifying the requirements and needs for future standardization. In conclusion a vision of the challenges and potentials for e-Learning standardization is outlined.

  16. 34 CFR 73.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 34 Education 1 2011-07-01 2011-07-01 false Cross-reference to employee ethical conduct standards... of Education STANDARDS OF CONDUCT § 73.1 Cross-reference to employee ethical conduct standards and... branch-wide Standards of Ethical Conduct at 5 CFR part 2635 and to the Department of Education regulation...

  17. 34 CFR 73.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 34 Education 1 2010-07-01 2010-07-01 false Cross-reference to employee ethical conduct standards... of Education STANDARDS OF CONDUCT § 73.1 Cross-reference to employee ethical conduct standards and... branch-wide Standards of Ethical Conduct at 5 CFR part 2635 and to the Department of Education regulation...

  18. 34 CFR 73.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 34 Education 1 2014-07-01 2014-07-01 false Cross-reference to employee ethical conduct standards... of Education STANDARDS OF CONDUCT § 73.1 Cross-reference to employee ethical conduct standards and... branch-wide Standards of Ethical Conduct at 5 CFR part 2635 and to the Department of Education regulation...

  19. 34 CFR 73.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 34 Education 1 2013-07-01 2013-07-01 false Cross-reference to employee ethical conduct standards... of Education STANDARDS OF CONDUCT § 73.1 Cross-reference to employee ethical conduct standards and... branch-wide Standards of Ethical Conduct at 5 CFR part 2635 and to the Department of Education regulation...

  20. 34 CFR 73.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 34 Education 1 2012-07-01 2012-07-01 false Cross-reference to employee ethical conduct standards... of Education STANDARDS OF CONDUCT § 73.1 Cross-reference to employee ethical conduct standards and... branch-wide Standards of Ethical Conduct at 5 CFR part 2635 and to the Department of Education regulation...

  1. Effect of Time Varying Gravity on DORIS processing for ITRF2013

    NASA Astrophysics Data System (ADS)

    Zelensky, N. P.; Lemoine, F. G.; Chinn, D. S.; Beall, J. W.; Melachroinos, S. A.; Beckley, B. D.; Pavlis, D.; Wimert, J.

    2013-12-01

    Computations are under way to develop a new time series of DORIS SINEX solutions to contribute to the development of the new realization of the terrestrial reference frame (c.f. ITRF2013). One of the improvements that are envisaged is the application of improved models of time-variable gravity in the background orbit modeling. At GSFC we have developed a time series of spherical harmonics to degree and order 5 (using the GOC02S model as a base), based on the processing of SLR and DORIS data to 14 satellites from 1993 to 2013. This is compared with the standard approach used in ITRF2008, based on the static model EIGEN-GL04S1 which included secular variations in only a few select coefficients. Previous work on altimeter satellite POD (c.f. TOPEX/Poseidon, Jason-1, Jason-2) has shown that the standard model is not adequate and orbit improvements are observed with application of more detailed models of time-variable gravity. In this study, we quantify the impact of TVG modeling on DORIS satellite POD, and ascertain the impact on DORIS station positions estimated weekly from 1993 to 2013. The numerous recent improvements to SLR and DORIS processing at GSFC include a more complete compliance to IERS2010 standards, improvements to SLR/DORIS measurement modeling, and improved non-conservative force modeling to DORIS satellites. These improvements will affect gravity coefficient estimates, POD, and the station solutions. Tests evaluate the impact of time varying gravity on tracking data residuals, station consistency, and the geocenter and scale reference frame parameters.

  2. Model of Distributed Learning Objects Repository for a Heterogenic Internet Environment

    ERIC Educational Resources Information Center

    Kaczmarek, Jerzy; Landowska, Agnieszka

    2006-01-01

    In this article, an extension of the existing structure of learning objects is described. The solution addresses the problem of the access and discovery of educational resources in the distributed Internet environment. An overview of e-learning standards, reference models, and problems with educational resources delivery is presented. The paper…

  3. 7 CFR 1728.97 - Incorporation by reference of electric standards and specifications.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 11 2014-01-01 2014-01-01 false Incorporation by reference of electric standards and...) RURAL UTILITIES SERVICE, DEPARTMENT OF AGRICULTURE ELECTRIC STANDARDS AND SPECIFICATIONS FOR MATERIALS AND CONSTRUCTION § 1728.97 Incorporation by reference of electric standards and specifications. The...

  4. 7 CFR 1728.97 - Incorporation by reference of electric standards and specifications.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 11 2012-01-01 2012-01-01 false Incorporation by reference of electric standards and...) RURAL UTILITIES SERVICE, DEPARTMENT OF AGRICULTURE ELECTRIC STANDARDS AND SPECIFICATIONS FOR MATERIALS AND CONSTRUCTION § 1728.97 Incorporation by reference of electric standards and specifications. The...

  5. PACS for surgery and interventional radiology: features of a Therapy Imaging and Model Management System (TIMMS).

    PubMed

    Lemke, Heinz U; Berliner, Leonard

    2011-05-01

    Appropriate use of information and communication technology (ICT) and mechatronic (MT) systems is viewed by many experts as a means to improve workflow and quality of care in the operating room (OR). This will require a suitable information technology (IT) infrastructure, as well as communication and interface standards, such as specialized extensions of DICOM, to allow data interchange between surgical system components in the OR. A design of such an infrastructure, sometimes referred to as surgical PACS, but better defined as a Therapy Imaging and Model Management System (TIMMS), will be introduced in this article. A TIMMS should support the essential functions that enable and advance image guided therapy, and in the future, a more comprehensive form of patient-model guided therapy. Within this concept, the "image-centric world view" of the classical PACS technology is complemented by an IT "model-centric world view". Such a view is founded in the special patient modelling needs of an increasing number of modern surgical interventions as compared to the imaging intensive working mode of diagnostic radiology, for which PACS was originally conceptualised and developed. The modelling aspects refer to both patient information and workflow modelling. Standards for creating and integrating information about patients, equipment, and procedures are vitally needed when planning for an efficient OR. The DICOM Working Group 24 (WG-24) has been established to develop DICOM objects and services related to image and model guided surgery. To determine these standards, it is important to define step-by-step surgical workflow practices and create interventional workflow models per procedures or per variable cases. As the boundaries between radiation therapy, surgery and interventional radiology are becoming less well-defined, precise patient models will become the greatest common denominator for all therapeutic disciplines. In addition to imaging, the focus of WG-24 is to serve the therapeutic disciplines by enabling modelling technology to be based on standards. Copyright © 2011. Published by Elsevier Ireland Ltd.

  6. Adaptive Flight Control Design with Optimal Control Modification on an F-18 Aircraft Model

    NASA Technical Reports Server (NTRS)

    Burken, John J.; Nguyen, Nhan T.; Griffin, Brian J.

    2010-01-01

    In the presence of large uncertainties, a control system needs to be able to adapt rapidly to regain performance. Fast adaptation is referred to as the implementation of adaptive control with a large adaptive gain to reduce the tracking error rapidly; however, a large adaptive gain can lead to high-frequency oscillations which can adversely affect the robustness of an adaptive control law. A new adaptive control modification is presented that can achieve robust adaptation with a large adaptive gain without incurring high-frequency oscillations as with the standard model-reference adaptive control. The modification is based on the minimization of the Y2 norm of the tracking error, which is formulated as an optimal control problem. The optimality condition is used to derive the modification using the gradient method. The optimal control modification results in a stable adaptation and allows a large adaptive gain to be used for better tracking while providing sufficient robustness. A damping term (v) is added in the modification to increase damping as needed. Simulations were conducted on a damaged F-18 aircraft (McDonnell Douglas, now The Boeing Company, Chicago, Illinois) with both the standard baseline dynamic inversion controller and the adaptive optimal control modification technique. The results demonstrate the effectiveness of the proposed modification in tracking a reference model.

  7. Telemetry Standards, RCC Standard 106-17. Chapter 3. Frequency Division Multiplexing Telemetry Standards

    DTIC Science & Technology

    2017-07-01

    any of the listed reference frequencies may be used provided the requirements for compensation rate of change are satisfied. If the reference...for in present discriminator systems when the nominal response rating of the channels is employed and a reference frequency is recorded with the...Telemetry Standards, RCC Standard 106-17 Chapter 3, July 2017 3-i CHAPTER 3 Frequency Division Multiplexing Telemetry Standards Acronyms

  8. 49 CFR 1019.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 8 2011-10-01 2011-10-01 false Cross-reference to employee ethical conduct... Cross-reference to employee ethical conduct standards and financial disclosure regulations. Members and employees of the Surface Transportation Board also should refer to the executive branch Standards of Ethical...

  9. 49 CFR 1019.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 8 2010-10-01 2010-10-01 false Cross-reference to employee ethical conduct... Cross-reference to employee ethical conduct standards and financial disclosure regulations. Members and employees of the Surface Transportation Board also should refer to the executive branch Standards of Ethical...

  10. 49 CFR 1019.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 8 2014-10-01 2014-10-01 false Cross-reference to employee ethical conduct... Cross-reference to employee ethical conduct standards and financial disclosure regulations. Members and employees of the Surface Transportation Board also should refer to the executive branch Standards of Ethical...

  11. 49 CFR 1019.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 8 2013-10-01 2013-10-01 false Cross-reference to employee ethical conduct... Cross-reference to employee ethical conduct standards and financial disclosure regulations. Members and employees of the Surface Transportation Board also should refer to the executive branch Standards of Ethical...

  12. 49 CFR 1019.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 8 2012-10-01 2012-10-01 false Cross-reference to employee ethical conduct... Cross-reference to employee ethical conduct standards and financial disclosure regulations. Members and employees of the Surface Transportation Board also should refer to the executive branch Standards of Ethical...

  13. Synthesis, molecular modeling and evaluation of α-glucosidase inhibition activity of 3,4-dihydroxy piperidines.

    PubMed

    Kasturi, Siva Prasad; Surarapu, Sujatha; Uppalanchi, Srinivas; Dwivedi, Shubham; Yogeeswari, Perumal; Sigalapalli, Dilep Kumar; Bathini, Nagendra Babu; Ethiraj, Krishna S; Anireddy, Jaya Shree

    2018-04-25

    Biological evaluation of 3,4-dihydroxy piperidines as α-glucosidase inhibitors is being reported for the first time. Forty-five derivatives (amides, di-amides and sulfonamides) were made using cis and trans 3,4-dihydroxy piperidines to evaluate their α-glucosidase inhibition activity. Polar groups (-OH, -NH 2 ) on phenyl ring having derivatives 5i, 5l, 7g, 7i &12j showed excellent activity compared to standard references. Acarbose, Voglibose and Miglitol were used as standard references. Molecular docking simulations were done for compounds to identify important binding modes responsible for inhibition activity of α-glucosidase. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  14. Standardizing CT lung density measure across scanner manufacturers.

    PubMed

    Chen-Mayer, Huaiyu Heather; Fuld, Matthew K; Hoppel, Bernice; Judy, Philip F; Sieren, Jered P; Guo, Junfeng; Lynch, David A; Possolo, Antonio; Fain, Sean B

    2017-03-01

    Computed Tomography (CT) imaging of the lung, reported in Hounsfield Units (HU), can be parameterized as a quantitative image biomarker for the diagnosis and monitoring of lung density changes due to emphysema, a type of chronic obstructive pulmonary disease (COPD). CT lung density metrics are global measurements based on lung CT number histograms, and are typically a quantity specifying either the percentage of voxels with CT numbers below a threshold, or a single CT number below which a fixed relative lung volume, nth percentile, falls. To reduce variability in the density metrics specified by CT attenuation, the Quantitative Imaging Biomarkers Alliance (QIBA) Lung Density Committee has organized efforts to conduct phantom studies in a variety of scanner models to establish a baseline for assessing the variations in patient studies that can be attributed to scanner calibration and measurement uncertainty. Data were obtained from a phantom study on CT scanners from four manufacturers with several protocols at various tube potential voltage (kVp) and exposure settings. Free from biological variation, these phantom studies provide an assessment of the accuracy and precision of the density metrics across platforms solely due to machine calibration and uncertainty of the reference materials. The phantom used in this study has three foam density references in the lung density region, which, after calibration against a suite of Standard Reference Materials (SRM) foams with certified physical density, establishes a HU-electron density relationship for each machine-protocol. We devised a 5-step calibration procedure combined with a simplified physical model that enabled the standardization of the CT numbers reported across a total of 22 scanner-protocol settings to a single energy (chosen at 80 keV). A standard deviation was calculated for overall CT numbers for each density, as well as by scanner and other variables, as a measure of the variability, before and after the standardization. In addition, a linear mixed-effects model was used to assess the heterogeneity across scanners, and the 95% confidence interval of the mean CT number was evaluated before and after the standardization. We show that after applying the standardization procedures to the phantom data, the instrumental reproducibility of the CT density measurement of the reference foams improved by more than 65%, as measured by the standard deviation of the overall mean CT number. Using the lung foam that did not participate in the calibration as a test case, a mixed effects model analysis shows that the 95% confidence intervals are [-862.0 HU, -851.3 HU] before standardization, and [-859.0 HU, -853.7 HU] after standardization to 80 keV. This is in general agreement with the expected CT number value at 80 keV of -855.9 HU with 95% CI of [-857.4 HU, -854.5 HU] based on the calibration and the uncertainty in the SRM certified density. This study provides a quantitative assessment of the variations expected in CT lung density measures attributed to non-biological sources such as scanner calibration and scanner x-ray spectrum and filtration. By removing scanner-protocol dependence from the measured CT numbers, higher accuracy and reproducibility of quantitative CT measures were attainable. The standardization procedures developed in study may be explored for possible application in CT lung density clinical data. © 2017 American Association of Physicists in Medicine.

  15. [Research model on commodity specification standard of radix Chinese materia medica].

    PubMed

    Kang, Chuan-Zhi; Zhou, Tao; Jiang, Wei-Ke; Huang, Lu-Qi; Guo, Lan-Ping

    2016-03-01

    As an important part of the market commodity circulation, the standard grade of Chinese traditional medicine commodity is very important to restrict the market order and guarantee the quality of the medicinal material. The State Council issuing the "protection and development of Chinese herbal medicine (2015-2020)" also make clear that the important task of improving the circulation of Chinese herbal medicine industry norms and the commodity specification standard of common traditional Chinese medicinal materials. However, as a large class of Chinese herbal medicines, the standard grade of the radix is more confused in the market circulation, and lack of a more reasonable study model in the development of the standard. Thus, this paper summarizes the research background, present situation and problems, and several key points of the commodity specification and grade standard in radix herbs. Then, the research model is introduced as an example of Pseudostellariae Radix, so as to provide technical support and reference for formulating commodity specifications and grades standard in other radix traditional Chinese medicinal materials. Copyright© by the Chinese Pharmaceutical Association.

  16. Predicting response before initiation of neoadjuvant chemotherapy in breast cancer using new methods for the analysis of dynamic contrast enhanced MRI (DCE MRI) data

    NASA Astrophysics Data System (ADS)

    DeGrandchamp, Joseph B.; Whisenant, Jennifer G.; Arlinghaus, Lori R.; Abramson, V. G.; Yankeelov, Thomas E.; Cárdenas-Rodríguez, Julio

    2016-03-01

    The pharmacokinetic parameters derived from dynamic contrast enhanced (DCE) MRI have shown promise as biomarkers for tumor response to therapy. However, standard methods of analyzing DCE MRI data (Tofts model) require high temporal resolution, high signal-to-noise ratio (SNR), and the Arterial Input Function (AIF). Such models produce reliable biomarkers of response only when a therapy has a large effect on the parameters. We recently reported a method that solves the limitations, the Linear Reference Region Model (LRRM). Similar to other reference region models, the LRRM needs no AIF. Additionally, the LRRM is more accurate and precise than standard methods at low SNR and slow temporal resolution, suggesting LRRM-derived biomarkers could be better predictors. Here, the LRRM, Non-linear Reference Region Model (NRRM), Linear Tofts model (LTM), and Non-linear Tofts Model (NLTM) were used to estimate the RKtrans between muscle and tumor (or the Ktrans for Tofts) and the tumor kep,TOI for 39 breast cancer patients who received neoadjuvant chemotherapy (NAC). These parameters and the receptor statuses of each patient were used to construct cross-validated predictive models to classify patients as complete pathological responders (pCR) or non-complete pathological responders (non-pCR) to NAC. Model performance was evaluated using area under the ROC curve (AUC). The AUC for receptor status alone was 0.62, while the best performance using predictors from the LRRM, NRRM, LTM, and NLTM were AUCs of 0.79, 0.55, 0.60, and 0.59 respectively. This suggests that the LRRM can be used to predict response to NAC in breast cancer.

  17. From plastic to gold: a unified classification scheme for reference standards in medical image processing

    NASA Astrophysics Data System (ADS)

    Lehmann, Thomas M.

    2002-05-01

    Reliable evaluation of medical image processing is of major importance for routine applications. Nonetheless, evaluation is often omitted or methodically defective when novel approaches or algorithms are introduced. Adopted from medical diagnosis, we define the following criteria to classify reference standards: 1. Reliance, if the generation or capturing of test images for evaluation follows an exactly determined and reproducible protocol. 2. Equivalence, if the image material or relationships considered within an algorithmic reference standard equal real-life data with respect to structure, noise, or other parameters of importance. 3. Independence, if any reference standard relies on a different procedure than that to be evaluated, or on other images or image modalities than that used routinely. This criterion bans the simultaneous use of one image for both, training and test phase. 4. Relevance, if the algorithm to be evaluated is self-reproducible. If random parameters or optimization strategies are applied, reliability of the algorithm must be shown before the reference standard is applied for evaluation. 5. Significance, if the number of reference standard images that are used for evaluation is sufficient large to enable statistically founded analysis. We demand that a true gold standard must satisfy the Criteria 1 to 3. Any standard only satisfying two criteria, i.e., Criterion 1 and Criterion 2 or Criterion 1 and Criterion 3, is referred to as silver standard. Other standards are termed to be from plastic. Before exhaustive evaluation based on gold or silver standards is performed, its relevance must be shown (Criterion 4) and sufficient tests must be carried out to found statistical analysis (Criterion 5). In this paper, examples are given for each class of reference standards.

  18. Defining the Core Archive Data Standards of the International Planetary Data Alliance (IPDA)

    NASA Technical Reports Server (NTRS)

    Hughes, J. Steven; Crichton, Dan; Beebe, Reta; Guinness, Ed; Heather, David; Zender, Joe

    2007-01-01

    A goal of the International Planetary Data Alliance (lPDA) is to develop a set of archive data standards that enable the sharing of scientific data across international agencies and missions. To help achieve this goal, the IPDA steering committee initiated a six month proj ect to write requirements for and draft an information model based on the Planetary Data System (PDS) archive data standards. The project had a special emphasis on data formats. A set of use case scenarios were first developed from which a set of requirements were derived for the IPDA archive data standards. The special emphasis on data formats was addressed by identifying data formats that have been used by PDS nodes and other agencies in the creation of successful data sets for the Planetary Data System (PDS). The dependency of the IPDA information model on the PDS archive standards required the compilation of a formal specification of the archive standards currently in use by the PDS. An ontology modelling tool was chosen to capture the information model from various sources including the Planetary Science Data Dictionary [I] and the PDS Standards Reference [2]. Exports of the modelling information from the tool database were used to produce the information model document using an object-oriented notation for presenting the model. The tool exports can also be used for software development and are directly accessible by semantic web applications.

  19. A low-cost density reference phantom for computed tomography.

    PubMed

    Levine, Zachary H; Li, Mingdong; Reeves, Anthony P; Yankelevitz, David F; Chen, Joseph J; Siegel, Eliot L; Peskin, Adele; Zeiger, Diana N

    2009-02-01

    The authors characterized a commercially available foam composed of polyurethane and polyisocyanurate which is marketed for modeling parts in the aircraft, automotive, and related industries. The authors found that the foam may be suitable for use as a density reference standard in the range below -400 Hounsfield units. This range is coincident with the density of lung tissue. The foam may be helpful in making the diagnosis of lung disease more systematic.

  20. 28 CFR 45.1 - Cross-reference to ethical standards and financial disclosure regulations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 28 Judicial Administration 2 2011-07-01 2011-07-01 false Cross-reference to ethical standards and...) EMPLOYEE RESPONSIBILITIES § 45.1 Cross-reference to ethical standards and financial disclosure regulations. Employees of the Department of Justice are subject to the executive branch-wide Standards of Ethical Conduct...

  1. 10 CFR 1010.102 - Cross-references to employee ethical conduct standards, financial disclosure regulations, and...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 4 2011-01-01 2011-01-01 false Cross-references to employee ethical conduct standards... Cross-references to employee ethical conduct standards, financial disclosure regulations, and other conduct rules. Employees of DOE are subject to the Standards of Ethical Conduct for Employees of the...

  2. 28 CFR 45.1 - Cross-reference to ethical standards and financial disclosure regulations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Cross-reference to ethical standards and...) EMPLOYEE RESPONSIBILITIES § 45.1 Cross-reference to ethical standards and financial disclosure regulations. Employees of the Department of Justice are subject to the executive branch-wide Standards of Ethical Conduct...

  3. 10 CFR 1010.102 - Cross-references to employee ethical conduct standards, financial disclosure regulations, and...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 4 2013-01-01 2013-01-01 false Cross-references to employee ethical conduct standards... Cross-references to employee ethical conduct standards, financial disclosure regulations, and other conduct rules. Employees of DOE are subject to the Standards of Ethical Conduct for Employees of the...

  4. 10 CFR 1010.102 - Cross-references to employee ethical conduct standards, financial disclosure regulations, and...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 4 2012-01-01 2012-01-01 false Cross-references to employee ethical conduct standards... Cross-references to employee ethical conduct standards, financial disclosure regulations, and other conduct rules. Employees of DOE are subject to the Standards of Ethical Conduct for Employees of the...

  5. 28 CFR 45.1 - Cross-reference to ethical standards and financial disclosure regulations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 28 Judicial Administration 2 2013-07-01 2013-07-01 false Cross-reference to ethical standards and...) EMPLOYEE RESPONSIBILITIES § 45.1 Cross-reference to ethical standards and financial disclosure regulations. Employees of the Department of Justice are subject to the executive branch-wide Standards of Ethical Conduct...

  6. 10 CFR 1010.102 - Cross-references to employee ethical conduct standards, financial disclosure regulations, and...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 4 2014-01-01 2014-01-01 false Cross-references to employee ethical conduct standards... Cross-references to employee ethical conduct standards, financial disclosure regulations, and other conduct rules. Employees of DOE are subject to the Standards of Ethical Conduct for Employees of the...

  7. 28 CFR 45.1 - Cross-reference to ethical standards and financial disclosure regulations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 28 Judicial Administration 2 2012-07-01 2012-07-01 false Cross-reference to ethical standards and...) EMPLOYEE RESPONSIBILITIES § 45.1 Cross-reference to ethical standards and financial disclosure regulations. Employees of the Department of Justice are subject to the executive branch-wide Standards of Ethical Conduct...

  8. 28 CFR 45.1 - Cross-reference to ethical standards and financial disclosure regulations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 28 Judicial Administration 2 2014-07-01 2014-07-01 false Cross-reference to ethical standards and...) EMPLOYEE RESPONSIBILITIES § 45.1 Cross-reference to ethical standards and financial disclosure regulations. Employees of the Department of Justice are subject to the executive branch-wide Standards of Ethical Conduct...

  9. A comparison of three infant skinfold reference standards: Tanner-Whitehouse, Cambridge Infant Growth Study, and WHO Child Growth Standards.

    PubMed

    Miller, Elizabeth M

    2015-10-01

    As researchers increasingly focus on early infancy as a critical period of development, there is a greater need for methodological tools that can address all aspects of infant growth. Infant skinfold measures, in particular, are measurements in need of reliable reference standards that encompass all ages of infants and provide an accurate assessment of the relative fatness of a population. This report evaluates three published reference standards for infant skinfold measurements: Tanner-Whitehouse, Cambridge Infant Growth Study, and the World Health Organization (WHO) Child Growth Standards. To assess these standards, triceps skinfolds from a population of rural Kenyan infants (n = 250) and triceps skinfolds and subscapular skinfolds from infants in the National Health and Nutrition Examination Survey 1999-2002 (NHANES; n = 1197) were calculated as z-scores from the lambda-mu-sigma curves provided by each reference population. The Tanner-Whitehouse standards represented both the Kenyan and US populations as lean, while the Cambridge standards represented both populations as overfat. The distribution of z-scores based on the WHO standards fell in the middle, but excluded infants from both populations who were below the age of 3 months. Based on these results, the WHO reference standard is the best skinfold reference standard for infants over the age of 3 months. For populations with infants of all ages, the Tanner-Whitehouse standards are recommended, despite representing both study populations as underfat. Ideally, the WHO will extend their reference standard to include infants between the ages of 0 and 3 months. © 2014 John Wiley & Sons Ltd.

  10. Operator's Manual for Waveform Generator Model RPG-6236-A

    DOT National Transportation Integrated Search

    1988-02-01

    The waveform generator, described in this manual, provides a reference signal standard for use in testing the performance of crash test data acquisition systems. During the test, the waveform generator provides the signal inputs to the data acquisiti...

  11. Calibration of Heat Stress Monitor and its Measurement Uncertainty

    NASA Astrophysics Data System (ADS)

    Ekici, Can

    2017-07-01

    Wet-bulb globe temperature (WBGT) equation is a heat stress index that gives information for the workers in the industrial areas. WBGT equation is described in ISO Standard 7243 (ISO 7243 in Hot environments—estimation of the heat stress on working man, based on the WBGT index, ISO, Geneva, 1982). WBGT is the result of the combined quantitative effects of the natural wet-bulb temperature, dry-bulb temperature, and air temperature. WBGT is a calculated parameter. WBGT uses input estimates, and heat stress monitor measures these quantities. In this study, the calibration method of a heat stress monitor is described, and the model function for measurement uncertainty is given. Sensitivity coefficients were derived according to GUM. Two-pressure humidity generators were used to generate a controlled environment. Heat stress monitor was calibrated inside of the generator. Two-pressure humidity generator, which is located in Turkish Standard Institution, was used as the reference device. This device is traceable to national standards. Two-pressure humidity generator includes reference temperature Pt-100 sensors. The reference sensor was sheltered with a wet wick for the calibration of natural wet-bulb thermometer. The reference sensor was centred into a black globe that has got 150 mm diameter for the calibration of the black globe thermometer.

  12. Characterization of a Recombinant Adeno-Associated Virus Type 2 Reference Standard Material

    PubMed Central

    Lock, Martin; McGorray, Susan; Auricchio, Alberto; Ayuso, Eduard; Beecham, E. Jeffrey; Blouin-Tavel, Véronique; Bosch, Fatima; Bose, Mahuya; Byrne, Barry J.; Caton, Tina; Chiorini, John A.; Chtarto, Abdelwahed; Clark, K. Reed; Conlon, Thomas; Darmon, Christophe; Doria, Monica; Douar, Anne; Flotte, Terence R.; Francis, Joyce D.; Francois, Achille; Giacca, Mauro; Korn, Michael T.; Korytov, Irina; Leon, Xavier; Leuchs, Barbara; Lux, Gabriele; Melas, Catherine; Mizukami, Hiroaki; Moullier, Philippe; Müller, Marcus; Ozawa, Keiya; Philipsberg, Tina; Poulard, Karine; Raupp, Christina; Rivière, Christel; Roosendaal, Sigrid D.; Samulski, R. Jude; Soltys, Steven M.; Surosky, Richard; Tenenbaum, Liliane; Thomas, Darby L.; van Montfort, Bart; Veres, Gabor; Wright, J. Fraser; Xu, Yili; Zelenaia, Olga; Zentilin, Lorena

    2010-01-01

    Abstract A recombinant adeno-associated virus serotype 2 Reference Standard Material (rAAV2 RSM) has been produced and characterized with the purpose of providing a reference standard for particle titer, vector genome titer, and infectious titer for AAV2 gene transfer vectors. Production and purification of the reference material were carried out by helper virus–free transient transfection and chromatographic purification. The purified bulk material was vialed, confirmed negative for microbial contamination, and then distributed for characterization along with standard assay protocols and assay reagents to 16 laboratories worldwide. Using statistical transformation and modeling of the raw data, mean titers and confidence intervals were determined for capsid particles ({X}, 9.18 × 1011 particles/ml; 95% confidence interval [CI], 7.89 × 1011 to 1.05 × 1012 particles/ml), vector genomes ({X}, 3.28 × 1010 vector genomes/ml; 95% CI, 2.70 × 1010 to 4.75 × 1010 vector genomes/ml), transducing units ({X}, 5.09 × 108 transducing units/ml; 95% CI, 2.00 × 108 to 9.60 × 108 transducing units/ml), and infectious units ({X}, 4.37 × 109 TCID50 IU/ml; 95% CI, 2.06 × 109 to 9.26 × 109 TCID50 IU/ml). Further analysis confirmed the identity of the reference material as AAV2 and the purity relative to nonvector proteins as greater than 94%. One obvious trend in the quantitative data was the degree of variation between institutions for each assay despite the relatively tight correlation of assay results within an institution. This relatively poor degree of interlaboratory precision and accuracy was apparent even though attempts were made to standardize the assays by providing detailed protocols and common reagents. This is the first time that such variation between laboratories has been thoroughly documented and the findings emphasize the need in the field for universal reference standards. The rAAV2 RSM has been deposited with the American Type Culture Collection and is available to the scientific community to calibrate laboratory-specific internal titer standards. Anticipated uses of the rAAV2 RSM are discussed. PMID:20486768

  13. Single-phase power distribution system power flow and fault analysis

    NASA Technical Reports Server (NTRS)

    Halpin, S. M.; Grigsby, L. L.

    1992-01-01

    Alternative methods for power flow and fault analysis of single-phase distribution systems are presented. The algorithms for both power flow and fault analysis utilize a generalized approach to network modeling. The generalized admittance matrix, formed using elements of linear graph theory, is an accurate network model for all possible single-phase network configurations. Unlike the standard nodal admittance matrix formulation algorithms, the generalized approach uses generalized component models for the transmission line and transformer. The standard assumption of a common node voltage reference point is not required to construct the generalized admittance matrix. Therefore, truly accurate simulation results can be obtained for networks that cannot be modeled using traditional techniques.

  14. Basic Geometric Support of Systems for Earth Observation from Geostationary and Highly Elliptical Orbits

    NASA Astrophysics Data System (ADS)

    Gektin, Yu. M.; Egoshkin, N. A.; Eremeev, V. V.; Kuznecov, A. E.; Moskatinyev, I. V.; Smelyanskiy, M. B.

    2017-12-01

    A set of standardized models and algorithms for geometric normalization and georeferencing images from geostationary and highly elliptical Earth observation systems is considered. The algorithms can process information from modern scanning multispectral sensors with two-coordinate scanning and represent normalized images in optimal projection. Problems of the high-precision ground calibration of the imaging equipment using reference objects, as well as issues of the flight calibration and refinement of geometric models using the absolute and relative reference points, are considered. Practical testing of the models, algorithms, and technologies is performed in the calibration of sensors for spacecrafts of the Electro-L series and during the simulation of the Arktika prospective system.

  15. Unified Bayesian Estimator of EEG Reference at Infinity: rREST (Regularized Reference Electrode Standardization Technique).

    PubMed

    Hu, Shiang; Yao, Dezhong; Valdes-Sosa, Pedro A

    2018-01-01

    The choice of reference for the electroencephalogram (EEG) is a long-lasting unsolved issue resulting in inconsistent usages and endless debates. Currently, both the average reference (AR) and the reference electrode standardization technique (REST) are two primary, apparently irreconcilable contenders. We propose a theoretical framework to resolve this reference issue by formulating both (a) estimation of potentials at infinity, and (b) determination of the reference, as a unified Bayesian linear inverse problem, which can be solved by maximum a posterior estimation. We find that AR and REST are very particular cases of this unified framework: AR results from biophysically non-informative prior; while REST utilizes the prior based on the EEG generative model. To allow for simultaneous denoising and reference estimation, we develop the regularized versions of AR and REST, named rAR and rREST, respectively. Both depend on a regularization parameter that is the noise to signal variance ratio. Traditional and new estimators are evaluated with this framework, by both simulations and analysis of real resting EEGs. Toward this end, we leverage the MRI and EEG data from 89 subjects which participated in the Cuban Human Brain Mapping Project. Generated artificial EEGs-with a known ground truth, show that relative error in estimating the EEG potentials at infinity is lowest for rREST. It also reveals that realistic volume conductor models improve the performances of REST and rREST. Importantly, for practical applications, it is shown that an average lead field gives the results comparable to the individual lead field. Finally, it is shown that the selection of the regularization parameter with Generalized Cross-Validation (GCV) is close to the "oracle" choice based on the ground truth. When evaluated with the real 89 resting state EEGs, rREST consistently yields the lowest GCV. This study provides a novel perspective to the EEG reference problem by means of a unified inverse solution framework. It may allow additional principled theoretical formulations and numerical evaluation of performance.

  16. High Speed Civil Transport Aircraft Simulation: Reference-H Cycle 1, MATLAB Implementation

    NASA Technical Reports Server (NTRS)

    Sotack, Robert A.; Chowdhry, Rajiv S.; Buttrill, Carey S.

    1999-01-01

    The mathematical model and associated code to simulate a high speed civil transport aircraft - the Boeing Reference H configuration - are described. The simulation was constructed in support of advanced control law research. In addition to providing time histories of the dynamic response, the code includes the capabilities for calculating trim solutions and for generating linear models. The simulation relies on the nonlinear, six-degree-of-freedom equations which govern the motion of a rigid aircraft in atmospheric flight. The 1962 Standard Atmosphere Tables are used along with a turbulence model to simulate the Earth atmosphere. The aircraft model has three parts - an aerodynamic model, an engine model, and a mass model. These models use the data from the Boeing Reference H cycle 1 simulation data base. Models for the actuator dynamics, landing gear, and flight control system are not included in this aircraft model. Dynamic responses generated by the nonlinear simulation are presented and compared with results generated from alternate simulations at Boeing Commercial Aircraft Company and NASA Langley Research Center. Also, dynamic responses generated using linear models are presented and compared with dynamic responses generated using the nonlinear simulation.

  17. [Nursing care systematization in rehabilitation unit, in accordance to Horta's conceptual model].

    PubMed

    Neves, Rinaldo de Souza

    2006-01-01

    The utilization of a conceptual model in the Nursing Attendance Systemization allows the development of activities based on theoretical references that can guide the implantation and the implementation of nursing proceedings in hospitals. In this article we examine the option made for the implementation of the Horta's conceptual model in the construction of a nursing attendance system in the Rehabilitation Unit of a public hospital located in the Federal District of Brazil. Through the utilization of these theoretical references it was possible to make available a data collection tool based on the basic human needs. The identification of these needs made possible the construction of the hierarchically disposed pyramid of the neurological patients' modified basic needs. Through this reference paper we intend to elaborate the prescription and nursing evolution based in the concepts and standards of the Horta's nursing process, making possible the inter-relationship of all phases of this attendance methodology.

  18. Enhanced semantic interoperability by profiling health informatics standards.

    PubMed

    López, Diego M; Blobel, Bernd

    2009-01-01

    Several standards applied to the healthcare domain support semantic interoperability. These standards are far from being completely adopted in health information system development, however. The objective of this paper is to provide a method and suggest the necessary tooling for reusing standard health information models, by that way supporting the development of semantically interoperable systems and components. The approach is based on the definition of UML Profiles. UML profiling is a formal modeling mechanism to specialize reference meta-models in such a way that it is possible to adapt those meta-models to specific platforms or domains. A health information model can be considered as such a meta-model. The first step of the introduced method identifies the standard health information models and tasks in the software development process in which healthcare information models can be reused. Then, the selected information model is formalized as a UML Profile. That Profile is finally applied to system models, annotating them with the semantics of the information model. The approach is supported on Eclipse-based UML modeling tools. The method is integrated into a comprehensive framework for health information systems development, and the feasibility of the approach is demonstrated in the analysis, design, and implementation of a public health surveillance system, reusing HL7 RIM and DIMs specifications. The paper describes a method and the necessary tooling for reusing standard healthcare information models. UML offers several advantages such as tooling support, graphical notation, exchangeability, extensibility, semi-automatic code generation, etc. The approach presented is also applicable for harmonizing different standard specifications.

  19. A pilot study of reference vibrotactile perception thresholds on the fingertip obtained with Malaysian healthy people using ISO 13091-1 equipment.

    PubMed

    Daud, Roshada; Maeda, Setsuo; Kameel, Nur Nazmin Mustafa; Ripin, Muhamad Yunus; Bakrun, Norazman; Md Zein, Raemy; Kido, Masaharu; Higuchi, Kiyotaka

    2004-04-01

    The purpose of this paper is to clarify the reference vibrotactile perception thresholds (VPT) for healthy people in Malaysia. The measurement equipment standard, ISO 13091-1, of the vibrotactile perception thresholds for the assessment of nerve dysfunction and the analysis and interpretation of measurements at the fingertips standard, ISO 13091-2, were published in ISO/TC108/SC4/WG8 on 2001 and 2003 individually. In the ISO 13091-2 standard, the reference VPT data were obtained from few research papers. Malaysian people's VPT data don't include to this standard. In Malaysia, when the VPT is using to diagnose of the hand-arm vibration syndrome, the reference VPT data need to compare with the worker's ones. But, Malaysia does not have the reference VPT data yet. So, in this paper, the VPT was measured by using ISO 13091-1 standard equipment to obtain the reference data for Malaysian people. And these data were compared with the ISO reference data on the ISO 13091-2 standard. From the comparison of these data, it was clear that the Malaysian healthy people's VPT data were consistent with the reference data of the ISO 13091-2 standard.

  20. The impact of US versus Indian BMD reference standards on the diagnosis of osteoporosis among South Asian Indians living in the United States

    PubMed Central

    Melamed, Alexander; Vittinghoff, Eric; Sriram, Usha; Schwartz, Ann V.; Kanaya, Alka M.

    2010-01-01

    The relationship between bone mineral density (BMD) and fracture risk is not well-established for non-white populations. There is no established BMD reference standard for South Asians. Dual energy x-ray absorptiometry (DXA) was used to measure BMD at total hip and lumbar spine in 150 US-based South Asian Indians. For each subject T-scores were calculated using BMD reference values based on US white, North Indian and South Indian populations, and the resulting WHO BMD category assignments were compared. Reference standards derived from Indian populations classified a larger proportion of US-based Indians as normal than did US white-based standards. The percentage of individuals reclassified when changing between reference standards varied by skeletal site and reference population origin, ranging from 13% (95% CI, 7–18%), when switching from US-white- to North Indian-based standard for total hip, to 40% (95% CI, 32–48%), when switching from US white to South Indian reference values for lumbar spine. These finding illustrate that choice of reference standard has a significant effect on the diagnosis of osteoporosis in South Asians, and underscore the importance of future research to quantify the relationship between BMD and fracture risk in this population. PMID:20663699

  1. 76 FR 8989 - Federal Acquisition Regulation; Updated Financial Accounting Standards Board Accounting References

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-16

    ... Acquisition Regulation; Updated Financial Accounting Standards Board Accounting References AGENCIES... Acquisition Regulation (FAR) to update references to authoritative accounting standards owing to the Financial... Accounting Principles (GAAP) (``Codification of GAAP''). DATES: Interested parties should submit written...

  2. Accuracy of computer-aided design models of the jaws produced using ultra-low MDCT doses and ASIR and MBIR.

    PubMed

    Al-Ekrish, Asma'a A; Alfadda, Sara A; Ameen, Wadea; Hörmann, Romed; Puelacher, Wolfgang; Widmann, Gerlig

    2018-06-16

    To compare the surface of computer-aided design (CAD) models of the maxilla produced using ultra-low MDCT doses combined with filtered backprojection (FBP), adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR) reconstruction techniques with that produced from a standard dose/FBP protocol. A cadaveric completely edentulous maxilla was imaged using a standard dose protocol (CTDIvol: 29.4 mGy) and FBP, in addition to 5 low dose test protocols (LD1-5) (CTDIvol: 4.19, 2.64, 0.99, 0.53, and 0.29 mGy) reconstructed with FBP, ASIR 50, ASIR 100, and MBIR. A CAD model from each test protocol was superimposed onto the reference model using the 'Best Fit Alignment' function. Differences between the test and reference models were analyzed as maximum and mean deviations, and root-mean-square of the deviations, and color-coded models were obtained which demonstrated the location, magnitude and direction of the deviations. Based upon the magnitude, size, and distribution of areas of deviations, CAD models from the following protocols were comparable to the reference model: FBP/LD1; ASIR 50/LD1 and LD2; ASIR 100/LD1, LD2, and LD3; MBIR/LD1. The following protocols demonstrated deviations mostly between 1-2 mm or under 1 mm but over large areas, and so their effect on surgical guide accuracy is questionable: FBP/LD2; MBIR/LD2, LD3, LD4, and LD5. The following protocols demonstrated large deviations over large areas and therefore were not comparable to the reference model: FBP/LD3, LD4, and LD5; ASIR 50/LD3, LD4, and LD5; ASIR 100/LD4, and LD5. When MDCT is used for CAD models of the jaws, dose reductions of 86% may be possible with FBP, 91% with ASIR 50, and 97% with ASIR 100. Analysis of the stability and accuracy of CAD/CAM surgical guides as directly related to the jaws is needed to confirm the results.

  3. In vitro vaccine potency testing: a proposal for reducing animal use for requalification testing.

    PubMed

    Brown, K; Stokes, W

    2012-01-01

    This paper proposes a program under which the use of animals for requalification of in vitro potency tests could be eliminated. Standard References (USDA/CVB nomenclature) would be developed, characterized, stored and monitored by selected reference laboratories worldwide. These laboratories would employ scientists skilled in protein and glycoprotein chemistry and equipped with state-of-the-art instruments for required analyses. After Standard References are established, the reference laboratories would provide them to the animal health industry as "gold standards". Companies would then establish and validate a correlation between the Standard Reference and the company Master Reference (USDA/CVB nomenclature) using an internal in vitro assay. After this correlation is established, the company could use the Standard References for qualifying, monitoring and requalifying company Master References without the use of animals. Such a program would eliminate the need for animals for requalification of Master References and the need for each company to develop and validate a battery of Master Reference Monitoring assays. It would also provide advantages in terms of reduced costs and reduced time for requalification testing. As such it would provide a strong incentive for companies to develop and use in vitro assays for potency testing.

  4. Data Modeling Challenges of Advanced Interoperability.

    PubMed

    Blobel, Bernd; Oemig, Frank; Ruotsalainen, Pekka

    2018-01-01

    Progressive health paradigms, involving many different disciplines and combining multiple policy domains, requires advanced interoperability solutions. This results in special challenges for modeling health systems. The paper discusses classification systems for data models and enterprise business architectures and compares them with the ISO Reference Architecture. On that basis, existing definitions, specifications and standards of data models for interoperability are evaluated and their limitations are discussed. Amendments to correctly use those models and to better meet the aforementioned challenges are offered.

  5. DeltaSA tool for source apportionment benchmarking, description and sensitivity analysis

    NASA Astrophysics Data System (ADS)

    Pernigotti, D.; Belis, C. A.

    2018-05-01

    DeltaSA is an R-package and a Java on-line tool developed at the EC-Joint Research Centre to assist and benchmark source apportionment applications. Its key functionalities support two critical tasks in this kind of studies: the assignment of a factor to a source in factor analytical models (source identification) and the model performance evaluation. The source identification is based on the similarity between a given factor and source chemical profiles from public databases. The model performance evaluation is based on statistical indicators used to compare model output with reference values generated in intercomparison exercises. The references values are calculated as the ensemble average of the results reported by participants that have passed a set of testing criteria based on chemical profiles and time series similarity. In this study, a sensitivity analysis of the model performance criteria is accomplished using the results of a synthetic dataset where "a priori" references are available. The consensus modulated standard deviation punc gives the best choice for the model performance evaluation when a conservative approach is adopted.

  6. Packet Traffic Dynamics Near Onset of Congestion in Data Communication Network Model

    NASA Astrophysics Data System (ADS)

    Lawniczak, A. T.; Tang, X.

    2006-05-01

    The dominant technology of data communication networks is the Packet Switching Network (PSN). It is a complex technology organized as various hierarchical layers according to the International Standard Organization (ISO) Open Systems Interconnect (OSI) Reference Model. The Network Layer of the ISO OSI Reference Model is responsible for delivering packets from their sources to their destinations and for dealing with congestion if it arises in a network. Thus, we focus on this layer and present an abstraction of the Network Layer of the ISO OSI Reference Model. Using this abstraction we investigate how onset of traffic congestion is affected for various routing algorithms by changes in network connection topology. We study how aggregate measures of network performance depend on network connection topology and routing. We explore packets traffic spatio-temporal dynamics near the phase transition point from free flow to congestion for various network connection topologies and routing algorithms. We consider static and adaptive routings. We present selected simulation results.

  7. Robust Optimal Adaptive Control Method with Large Adaptive Gain

    NASA Technical Reports Server (NTRS)

    Nguyen, Nhan T.

    2009-01-01

    In the presence of large uncertainties, a control system needs to be able to adapt rapidly to regain performance. Fast adaptation is referred to the implementation of adaptive control with a large adaptive gain to reduce the tracking error rapidly. However, a large adaptive gain can lead to high-frequency oscillations which can adversely affect robustness of an adaptive control law. A new adaptive control modification is presented that can achieve robust adaptation with a large adaptive gain without incurring high-frequency oscillations as with the standard model-reference adaptive control. The modification is based on the minimization of the Y2 norm of the tracking error, which is formulated as an optimal control problem. The optimality condition is used to derive the modification using the gradient method. The optimal control modification results in a stable adaptation and allows a large adaptive gain to be used for better tracking while providing sufficient stability robustness. Simulations were conducted for a damaged generic transport aircraft with both standard adaptive control and the adaptive optimal control modification technique. The results demonstrate the effectiveness of the proposed modification in tracking a reference model while maintaining a sufficient time delay margin.

  8. A Novel Multilayer Correlation Maximization Model for Improving CCA-Based Frequency Recognition in SSVEP Brain-Computer Interface.

    PubMed

    Jiao, Yong; Zhang, Yu; Wang, Yu; Wang, Bei; Jin, Jing; Wang, Xingyu

    2018-05-01

    Multiset canonical correlation analysis (MsetCCA) has been successfully applied to optimize the reference signals by extracting common features from multiple sets of electroencephalogram (EEG) for steady-state visual evoked potential (SSVEP) recognition in brain-computer interface application. To avoid extracting the possible noise components as common features, this study proposes a sophisticated extension of MsetCCA, called multilayer correlation maximization (MCM) model for further improving SSVEP recognition accuracy. MCM combines advantages of both CCA and MsetCCA by carrying out three layers of correlation maximization processes. The first layer is to extract the stimulus frequency-related information in using CCA between EEG samples and sine-cosine reference signals. The second layer is to learn reference signals by extracting the common features with MsetCCA. The third layer is to re-optimize the reference signals set in using CCA with sine-cosine reference signals again. Experimental study is implemented to validate effectiveness of the proposed MCM model in comparison with the standard CCA and MsetCCA algorithms. Superior performance of MCM demonstrates its promising potential for the development of an improved SSVEP-based brain-computer interface.

  9. Physiotherapy triage assessment of patients referred for orthopaedic consultation - Long-term follow-up of health-related quality of life, pain-related disability and sick leave.

    PubMed

    Samsson, Karin S; Larsson, Maria E H

    2015-02-01

    The literature indicates that physiotherapy triage assessment can be efficient for patients referred for orthopaedic consultation, however long-term follow up of patient reported outcome measures are not available. To report a long-term evaluation of patient-reported health-related quality of life, pain-related disability, and sick leave after a physiotherapy triage assessment of patients referred for orthopaedic consultation compared with standard practice. Patients referred for orthopaedic consultation (n = 208) were randomised to physiotherapy triage assessment or standard practice. The randomised cohort was analysed on an intention-to-treat (ITT) basis. The patient reported outcome measures EuroQol VAS (self-reported health-state), EuroQol 5D-3L (EQ-5D) and Pain Disability Index (PDI) were assessed at baseline and after 3, 6 and 12 months. EQ VAS was analysed using a repeated measure ANOVA. PDI and EQ-5D were analysed using a marginal logistic regression model. Sick leave was analysed for the 12 months following consultation using a Mann-Whitney U-test. The patients rated a significantly better health-state at 3 after physiotherapy triage assessment [mean difference -5.7 (95% CI -11.1; -0.2); p = 0.04]. There were no other statistically significant differences in perceived health-related quality of life or pain related disability between the groups at any of the follow-ups, or sick leave. This study reports that the long-term follow up of the patient related outcome measures health-related quality of life, pain-related disability and sick leave after physiotherapy triage assessment did not differ from standard practice, indicating the possible benefits of implementation of this model of care. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. A Framework for Establishing Standard Reference Scale of Texture by Multivariate Statistical Analysis Based on Instrumental Measurement and Sensory Evaluation.

    PubMed

    Zhi, Ruicong; Zhao, Lei; Xie, Nan; Wang, Houyin; Shi, Bolin; Shi, Jingye

    2016-01-13

    A framework of establishing standard reference scale (texture) is proposed by multivariate statistical analysis according to instrumental measurement and sensory evaluation. Multivariate statistical analysis is conducted to rapidly select typical reference samples with characteristics of universality, representativeness, stability, substitutability, and traceability. The reasonableness of the framework method is verified by establishing standard reference scale of texture attribute (hardness) with Chinese well-known food. More than 100 food products in 16 categories were tested using instrumental measurement (TPA test), and the result was analyzed with clustering analysis, principal component analysis, relative standard deviation, and analysis of variance. As a result, nine kinds of foods were determined to construct the hardness standard reference scale. The results indicate that the regression coefficient between the estimated sensory value and the instrumentally measured value is significant (R(2) = 0.9765), which fits well with Stevens's theory. The research provides reliable a theoretical basis and practical guide for quantitative standard reference scale establishment on food texture characteristics.

  11. A low-cost density reference phantom for computed tomography

    PubMed Central

    Levine, Zachary H.; Li, Mingdong; Reeves, Anthony P.; Yankelevitz, David F.; Chen, Joseph J.; Siegel, Eliot L.; Peskin, Adele; Zeiger, Diana N.

    2009-01-01

    The authors characterized a commercially available foam composed of polyurethane and polyisocyanurate which is marketed for modeling parts in the aircraft, automotive, and related industries. The authors found that the foam may be suitable for use as a density reference standard in the range below −400 Hounsfield units. This range is coincident with the density of lung tissue. The foam may be helpful in making the diagnosis of lung disease more systematic. PMID:19291968

  12. Changes in radiation dose with variations in human anatomy: moderately and severely obese adults.

    PubMed

    Clark, Landon D; Stabin, Michael G; Fernald, Michael J; Brill, Aaron B

    2010-06-01

    The phantoms used in standardized dose assessment are based on a median (i.e., 50th percentile) individual of a large population, for example, adult males or females or children of a particular age. Here we describe phantoms that model instead the influence of obesity on specific absorbed fractions (SAFs) and dose factors in adults. The literature was reviewed to evaluate how individual organ sizes change with variations in body weight in mildly and severely obese adult men and women. On the basis of the literature evaluation, changes were made to our deformable reference adult male and female total-body models. Monte Carlo simulations of radiation transport were performed. SAFs for photons were generated for mildly and severely obese adults, and comparisons were made to the reference (50th) percentile SAF values. SAFs studied between the obese phantoms and the 50th percentile reference phantoms were not significantly different from the reference 50th percentile individual, with the exception of intestines irradiating some abdominal organs, because of an increase in separation between folds caused by an increase in mesenteric adipose deposits. Some low-energy values for certain organ pairs were different, possibly due only to the statistical variability of the data at these low energies. The effect of obesity on dose calculations for internal emitters is minor and may be neglected in the routine use of standardized dose estimates.

  13. The Value Estimation of an HFGW Frequency Time Standard for Telecommunications Network Optimization

    NASA Astrophysics Data System (ADS)

    Harper, Colby; Stephenson, Gary

    2007-01-01

    The emerging technology of gravitational wave control is used to augment a communication system using a development roadmap suggested in Stephenson (2003) for applications emphasized in Baker (2005). In the present paper consideration is given to the value of a High Frequency Gravitational Wave (HFGW) channel purely as providing a method of frequency and time reference distribution for use within conventional Radio Frequency (RF) telecommunications networks. Specifically, the native value of conventional telecommunications networks may be optimized by using an unperturbed frequency time standard (FTS) to (1) improve terminal navigation and Doppler estimation performance via improved time difference of arrival (TDOA) from a universal time reference, and (2) improve acquisition speed, coding efficiency, and dynamic bandwidth efficiency through the use of a universal frequency reference. A model utilizing a discounted cash flow technique provides an estimation of the additional value using HFGW FTS technology could bring to a mixed technology HFGW/RF network. By applying a simple net present value analysis with supporting reference valuations to such a network, it is demonstrated that an HFGW FTS could create a sizable improvement within an otherwise conventional RF telecommunications network. Our conservative model establishes a low-side value estimate of approximately 50B USD Net Present Value for an HFGW FTS service, with reasonable potential high-side values to significant multiples of this low-side value floor.

  14. 18 CFR 38.2 - Incorporation by reference of North American Energy Standards Board Wholesale Electric Quadrant...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ....13, 001-1.0, 001-9.7, 001-14.1.3, and 001-15.1.2); (2) Open Access Same-Time Information Systems... reference of North American Energy Standards Board Wholesale Electric Quadrant standards. 38.2 Section 38.2... UTILITIES § 38.2 Incorporation by reference of North American Energy Standards Board Wholesale Electric...

  15. Towards a Framework for Developing Semantic Relatedness Reference Standards

    PubMed Central

    Pakhomov, Serguei V.S.; Pedersen, Ted; McInnes, Bridget; Melton, Genevieve B.; Ruggieri, Alexander; Chute, Christopher G.

    2010-01-01

    Our objective is to develop a framework for creating reference standards for functional testing of computerized measures of semantic relatedness. Currently, research on computerized approaches to semantic relatedness between biomedical concepts relies on reference standards created for specific purposes using a variety of methods for their analysis. In most cases, these reference standards are not publicly available and the published information provided in manuscripts that evaluate computerized semantic relatedness measurement approaches is not sufficient to reproduce the results. Our proposed framework is based on the experiences of medical informatics and computational linguistics communities and addresses practical and theoretical issues with creating reference standards for semantic relatedness. We demonstrate the use of the framework on a pilot set of 101 medical term pairs rated for semantic relatedness by 13 medical coding experts. While the reliability of this particular reference standard is in the “moderate” range; we show that using clustering and factor analyses offers a data-driven approach to finding systematic differences among raters and identifying groups of potential outliers. We test two ontology-based measures of relatedness and provide both the reference standard containing individual ratings and the R program used to analyze the ratings as open-source. Currently, these resources are intended to be used to reproduce and compare results of studies involving computerized measures of semantic relatedness. Our framework may be extended to the development of reference standards in other research areas in medical informatics including automatic classification, information retrieval from medical records and vocabulary/ontology development. PMID:21044697

  16. Hg0 and HgCl2 Reference Gas Standards: ?NIST Traceability ...

    EPA Pesticide Factsheets

    EPA and NIST have collaborated to establish the necessary procedures for establishing the required NIST traceability of commercially-provided Hg0 and HgCl2 reference generators. This presentation will discuss the approach of a joint EPA/NIST study to accurately quantify the true concentrations of Hg0 and HgCl2 reference gases produced from high quality, NIST-traceable, commercial Hg0 and HgCl2 generators. This presentation will also discuss the availability of HCl and Hg0 compressed reference gas standards as a result of EPA's recently approved Alternative Methods 114 and 118. Gaseous elemental mercury (Hg0) and oxidized mercury (HgCl2) reference standards are integral to the use of mercury continuous emissions monitoring systems (Hg CEMS) for regulatory compliance emissions monitoring. However, a quantitative disparity of approximately 7-10% has been observed between commercial Hg0 and HgCl2 reference gases which currently limits the use of (HgCl2) reference gas standards. Resolving this disparity would enable the expanded use of (HgCl2) reference gas standards for regulatory compliance purposes.

  17. Description and status update on GELLO: a proposed standardized object-oriented expression language for clinical decision support.

    PubMed

    Sordo, Margarita; Boxwala, Aziz A; Ogunyemi, Omolola; Greenes, Robert A

    2004-01-01

    A major obstacle to sharing computable clinical knowledge is the lack of a common language for specifying expressions and criteria. Such a language could be used to specify decision criteria, formulae, and constraints on data and action. Al-though the Arden Syntax addresses this problem for clinical rules, its generalization to HL7's object-oriented data model is limited. The GELLO Expression language is an object-oriented language used for expressing logical conditions and computations in the GLIF3 (GuideLine Interchange Format, v. 3) guideline modeling language. It has been further developed under the auspices of the HL7 Clinical Decision Support Technical Committee, as a proposed HL7 standard., GELLO is based on the Object Constraint Language (OCL), because it is vendor-independent, object-oriented, and side-effect-free. GELLO expects an object-oriented data model. Although choice of model is arbitrary, standardization is facilitated by ensuring that the data model is compatible with the HL7 Reference Information Model (RIM).

  18. Improving atomic force microscopy imaging by a direct inverse asymmetric PI hysteresis model.

    PubMed

    Wang, Dong; Yu, Peng; Wang, Feifei; Chan, Ho-Yin; Zhou, Lei; Dong, Zaili; Liu, Lianqing; Li, Wen Jung

    2015-02-03

    A modified Prandtl-Ishlinskii (PI) model, referred to as a direct inverse asymmetric PI (DIAPI) model in this paper, was implemented to reduce the displacement error between a predicted model and the actual trajectory of a piezoelectric actuator which is commonly found in AFM systems. Due to the nonlinearity of the piezoelectric actuator, the standard symmetric PI model cannot precisely describe the asymmetric motion of the actuator. In order to improve the accuracy of AFM scans, two series of slope parameters were introduced in the PI model to describe both the voltage-increase-loop (trace) and voltage-decrease-loop (retrace). A feedforward controller based on the DIAPI model was implemented to compensate hysteresis. Performance of the DIAPI model and the feedforward controller were validated by scanning micro-lenses and standard silicon grating using a custom-built AFM.

  19. Revised Depletions and New Constraints on Interstellar Dust Composition

    NASA Technical Reports Server (NTRS)

    Snow, Theodore P.; Witt, Adolf N.

    1996-01-01

    We have reviewed the literature on composition of young stars, both hot and cool, as well as older solar-type stars. We find that all these classes of stars have lower abundances of the heavy elements (specifically C, N, O, Mg, Si, and Fe) than the sun. Therefore studies of interstellar depletions in which the solar composition is used as the reference standard are probably in error, tending to overestimate the total quantities of these elements, hence the depletions. We have revised the depletion estimates, using stellar abundances as the reference standard and making use of recent IS gas-phase abundance measurements. As a result of our revised depletions, we can place new and stringent constraints on several published models for the interstellar dust.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Knirsch, Fabian; Engel, Dominik; Neureiter, Christian

    In a smart grid, data and information are transported, transmitted, stored, and processed with various stakeholders having to cooperate effectively. Furthermore, personal data is the key to many smart grid applications and therefore privacy impacts have to be taken into account. For an effective smart grid, well integrated solutions are crucial and for achieving a high degree of customer acceptance, privacy should already be considered at design time of the system. To assist system engineers in early design phase, frameworks for the automated privacy evaluation of use cases are important. For evaluation, use cases for services and software architectures needmore » to be formally captured in a standardized and commonly understood manner. In order to ensure this common understanding for all kinds of stakeholders, reference models have recently been developed. In this paper we present a model-driven approach for the automated assessment of such services and software architectures in the smart grid that builds on the standardized reference models. The focus of qualitative and quantitative evaluation is on privacy. For evaluation, the framework draws on use cases from the University of Southern California microgrid.« less

  1. Reevaluation of the NOAA/CMDL carbon monoxide reference scale and comparisons with CO reference gases at NASA-Langley and the Fraunhofer Institut

    NASA Technical Reports Server (NTRS)

    Novelli, P. C.; Collins, J. E., Jr.; Myers, R. C.; Sachse, G. W.; Scheel, H. E.

    1994-01-01

    The carbon monoxide (CO) reference scale created by the National Oceanic and Atmospheric Administration/Climate Monitoring and Diagnostics Laboratory (NOAA/CMDL) is used to quantify measurements of CO in the atmosphere, calibrate standards of other laboratories and to otherwise provide reference gases to the community measuring atmospheric CO. This reference scale was created based upon a set of primary standards prepared by gravimetric methods at CMDL and has been propagated to a set of working standards. In this paper we compare CO mixing ratios assigned to the working standards by three approaches: (1) calibration against the original gravimetric standards, (2) calibration using only working standards as the reference gas, and (3) calibration against three new gravimetric standards prepared to CMDL. The agreement between these values was typically better than 1%. The calibration histories of CMDL working standards are reviewed with respect to expected rates of CO change in the atmosphere. Using a Monte Carlo approach to simulate the effect of drifting standards on calculated mixing ratios, we conclude that the error solely associated with the maintenance of standards will limit the ability to detect small CO changes in the atmosphere. We also report results of intercalibration experiments conducted between CMDL and the Diode Laser Sensor Group (DACOM) at the NASA Langley Research Center (Hampton, Virginia), and CMDL and the Fraunhofer-Institut (Garmisch-Partenkirchen, Germany). Each laboratory calibrated several working standards for CO using their reference gases, and these results were compared to calibrations conducted by CMDL. The intercomparison of eight standards (CO concentrations between approximately 100 and approximately 165 ppb) by CMDL and NASA agreed to better than +/- 2%. The calibration of six standards (CO concentrations between approximately 50 and approximately 210 ppb) by CMDL and the Fraunhofer-Institut agreed to within +/- 2% for four standards, and to within +/- 5% for all six standards.

  2. The National Map seamless digital elevation model specifications

    USGS Publications Warehouse

    Archuleta, Christy-Ann M.; Constance, Eric W.; Arundel, Samantha T.; Lowe, Amanda J.; Mantey, Kimberly S.; Phillips, Lori A.

    2017-08-02

    This specification documents the requirements and standards used to produce the seamless elevation layers for The National Map of the United States. Seamless elevation data are available for the conterminous United States, Hawaii, Alaska, and the U.S. territories, in three different resolutions—1/3-arc-second, 1-arc-second, and 2-arc-second. These specifications include requirements and standards information about source data requirements, spatial reference system, distribution tiling schemes, horizontal resolution, vertical accuracy, digital elevation model surface treatment, georeferencing, data source and tile dates, distribution and supporting file formats, void areas, metadata, spatial metadata, and quality assurance and control.

  3. Standard-compliant real-time transmission of ECGs: harmonization of ISO/IEEE 11073-PHD and SCP-ECG.

    PubMed

    Trigo, Jesús D; Chiarugi, Franco; Alesanco, Alvaro; Martínez-Espronceda, Miguel; Chronaki, Catherine E; Escayola, Javier; Martínez, Ignacio; García, José

    2009-01-01

    Ambient assisted living and integrated care in an aging society is based on the vision of the lifelong Electronic Health Record calling for HealthCare Information Systems and medical device interoperability. For medical devices this aim can be achieved by the consistent implementation of harmonized international interoperability standards. The ISO/IEEE 11073 (x73) family of standards is a reference standard for medical device interoperability. In its Personal Health Device (PHD) version several devices have been included, but an ECG device specialization is not yet available. On the other hand, the SCP-ECG standard for short-term diagnostic ECGs (EN1064) has been recently approved as an international standard ISO/IEEE 11073-91064:2009. In this paper, the relationships between a proposed x73-PHD model for an ECG device and the fields of the SCP-ECG standard are investigated. A proof-of-concept implementation of the proposed x73-PHD ECG model is also presented, identifying open issues to be addressed by standards development for the wider interoperability adoption of x73-PHD standards.

  4. 22 CFR 705.101 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 22 Foreign Relations 2 2011-04-01 2009-04-01 true Cross-reference to employee ethical conduct... INVESTMENT CORPORATION ADMINISTRATIVE PROVISIONS EMPLOYEE ETHICAL CONDUCT STANDARDS AND FINANCIAL DISCLOSURE REGULATIONS § 705.101 Cross-reference to employee ethical conduct standards and financial disclosure...

  5. Certification of elements in and use of standard reference material 3280 multivitamin/multielement tablets

    USDA-ARS?s Scientific Manuscript database

    Standard Reference Material (SRM) 3280 Multivitamin/Multielement Tablets was issued by the National Institute of Standards and Technology (NIST) in 2009 and has certified and reference mass fraction values for 13 vitamins, 26 elements, and 2 carotenoids. Elements were measured using two or more ana...

  6. 22 CFR 705.101 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 22 Foreign Relations 2 2010-04-01 2010-04-01 true Cross-reference to employee ethical conduct... INVESTMENT CORPORATION ADMINISTRATIVE PROVISIONS EMPLOYEE ETHICAL CONDUCT STANDARDS AND FINANCIAL DISCLOSURE REGULATIONS § 705.101 Cross-reference to employee ethical conduct standards and financial disclosure...

  7. 22 CFR 705.101 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 22 Foreign Relations 2 2014-04-01 2014-04-01 false Cross-reference to employee ethical conduct... INVESTMENT CORPORATION ADMINISTRATIVE PROVISIONS EMPLOYEE ETHICAL CONDUCT STANDARDS AND FINANCIAL DISCLOSURE REGULATIONS § 705.101 Cross-reference to employee ethical conduct standards and financial disclosure...

  8. 22 CFR 705.101 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 22 Foreign Relations 2 2013-04-01 2009-04-01 true Cross-reference to employee ethical conduct... INVESTMENT CORPORATION ADMINISTRATIVE PROVISIONS EMPLOYEE ETHICAL CONDUCT STANDARDS AND FINANCIAL DISCLOSURE REGULATIONS § 705.101 Cross-reference to employee ethical conduct standards and financial disclosure...

  9. 22 CFR 705.101 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 22 Foreign Relations 2 2012-04-01 2009-04-01 true Cross-reference to employee ethical conduct... INVESTMENT CORPORATION ADMINISTRATIVE PROVISIONS EMPLOYEE ETHICAL CONDUCT STANDARDS AND FINANCIAL DISCLOSURE REGULATIONS § 705.101 Cross-reference to employee ethical conduct standards and financial disclosure...

  10. Agreement between diagnoses reached by clinical examination and available reference standards: a prospective study of 216 patients with lumbopelvic pain

    PubMed Central

    Laslett, Mark; McDonald, Barry; Tropp, Hans; Aprill, Charles N; Öberg, Birgitta

    2005-01-01

    Background The tissue origin of low back pain (LBP) or referred lower extremity symptoms (LES) may be identified in about 70% of cases using advanced imaging, discography and facet or sacroiliac joint blocks. These techniques are invasive and availability varies. A clinical examination is non-invasive and widely available but its validity is questioned. Diagnostic studies usually examine single tests in relation to single reference standards, yet in clinical practice, clinicians use multiple tests and select from a range of possible diagnoses. There is a need for studies that evaluate the diagnostic performance of clinical diagnoses against available reference standards. Methods We compared blinded clinical diagnoses with diagnoses based on available reference standards for known causes of LBP or LES such as discography, facet, sacroiliac or hip joint blocks, epidurals injections, advanced imaging studies or any combination of these tests. A prospective, blinded validity design was employed. Physiotherapists examined consecutive patients with chronic lumbopelvic pain and/or referred LES scheduled to receive the reference standard examinations. When diagnoses were in complete agreement regardless of complexity, "exact" agreement was recorded. When the clinical diagnosis was included within the reference standard diagnoses, "clinical agreement" was recorded. The proportional chance criterion (PCC) statistic was used to estimate agreement on multiple diagnostic possibilities because it accounts for the prevalence of individual categories in the sample. The kappa statistic was used to estimate agreement on six pathoanatomic diagnoses. Results In a sample of chronic LBP patients (n = 216) with high levels of disability and distress, 67% received a patho-anatomic diagnosis based on available reference standards, and 10% had more than one tissue origin of pain identified. For 27 diagnostic categories and combinations, chance clinical agreement (PCC) was estimated at 13%. "Exact" agreement between clinical and reference standard diagnoses was 32% and "clinical agreement" 51%. For six pathoanatomic categories (disc, facet joint, sacroiliac joint, hip joint, nerve root and spinal stenosis), PCC was 33% with actual agreement 56%. There was no overlap of 95% confidence intervals on any comparison. Diagnostic agreement on the six most common patho-anatomic categories produced a kappa of 0.31. Conclusion Clinical diagnoses agree with reference standards diagnoses more often than chance. Using available reference standards, most patients can have a tissue source of pain identified. PMID:15943873

  11. Assessing operating characteristics of CAD algorithms in the absence of a gold standard

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roy Choudhury, Kingshuk; Paik, David S.; Yi, Chin A.

    2010-04-15

    Purpose: The authors examine potential bias when using a reference reader panel as ''gold standard'' for estimating operating characteristics of CAD algorithms for detecting lesions. As an alternative, the authors propose latent class analysis (LCA), which does not require an external gold standard to evaluate diagnostic accuracy. Methods: A binomial model for multiple reader detections using different diagnostic protocols was constructed, assuming conditional independence of readings given true lesion status. Operating characteristics of all protocols were estimated by maximum likelihood LCA. Reader panel and LCA based estimates were compared using data simulated from the binomial model for a range ofmore » operating characteristics. LCA was applied to 36 thin section thoracic computed tomography data sets from the Lung Image Database Consortium (LIDC): Free search markings of four radiologists were compared to markings from four different CAD assisted radiologists. For real data, bootstrap-based resampling methods, which accommodate dependence in reader detections, are proposed to test of hypotheses of differences between detection protocols. Results: In simulation studies, reader panel based sensitivity estimates had an average relative bias (ARB) of -23% to -27%, significantly higher (p-value <0.0001) than LCA (ARB -2% to -6%). Specificity was well estimated by both reader panel (ARB -0.6% to -0.5%) and LCA (ARB 1.4%-0.5%). Among 1145 lesion candidates LIDC considered, LCA estimated sensitivity of reference readers (55%) was significantly lower (p-value 0.006) than CAD assisted readers' (68%). Average false positives per patient for reference readers (0.95) was not significantly lower (p-value 0.28) than CAD assisted readers' (1.27). Conclusions: Whereas a gold standard based on a consensus of readers may substantially bias sensitivity estimates, LCA may be a significantly more accurate and consistent means for evaluating diagnostic accuracy.« less

  12. Alternative mass reference standards for direct analysis in real time mass spectrometry.

    PubMed

    Cody, Robert B; Dane, A John

    2016-05-30

    Mass spectra were acquired with the Direct Analysis in Real Time (DART®) ion source for an amine-terminated polyether used as positive-ion mass reference standards and for several fluorinated materials commonly used as negative-ion reference standards for mass spectrometry. A commercial time-of-flight mass spectrometer equipped with a DART ion source was used for all measurements. Mass reference standards deposited onto the sealed end of a glass melting point tube were suspended in the DART gas stream for analysis. A polyetheramine (Jeffamine® M-600) produced intense peaks corresponding to protonated molecules. Perfluorotributylamine (PFTBA), and perfluorotripentylamine, gave useful reference spectra for different m/z ranges. DART mass spectra of Ultramark 1621® resembled those previously reported for Fast Atom Bombardment (FAB) and Electrospray Ionization (ESI). Fomblin®Y, a fluorinated ether, was the most useful negative-ion reference standard of the materials tested. The material is commercially available, inexpensive, and provides reference peaks covering the m/z range 85 to >3000. Jeffamine-M600 was found to be a convenient alternative to polyethers such as polyethylene glycol (PEG) for DART positive-ion mass calibration. Fomblin Y was suitable for use as a negative-ion reference standard. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  13. Updating OSHA standards based on national consensus standards. Direct final rule.

    PubMed

    2007-12-14

    In this direct final rule, the Agency is removing several references to consensus standards that have requirements that duplicate, or are comparable to, other OSHA rules; this action includes correcting a paragraph citation in one of these OSHA rules. The Agency also is removing a reference to American Welding Society standard A3.0-1969 ("Terms and Definitions") in its general-industry welding standards. This rulemaking is a continuation of OSHA's ongoing effort to update references to consensus and industry standards used throughout its rules.

  14. Optical-Fiber Power Meter Comparison between NIST and KRISS.

    PubMed

    Vayshenker, I; Kim, S K; Hong, K; Lee, D-H; Livigni, D J; Li, X; Lehman, J H

    2012-01-01

    We describe the results of a comparison of reference standards between the National Institute of Standards and Technology (NIST-USA) and Korea Research Institute of Standards and Science (KRISS-R.O. Korea) for optical fiber-based power measurements at wavelengths of 1302 nm and 1546 nm. We compare the laboratories' reference standards by means of a temperature-controlled optical trap detector. Measurement results showed the largest difference of less than 2.5 parts in 10(3), which is within the combined standard (k=1) uncertainty for the two laboratories' reference standards.

  15. Reference values for pulmonary diffusing capacity for adult native Finns.

    PubMed

    Kainu, Annette; Toikka, Jyri; Vanninen, Esko; Timonen, Kirsi L

    2017-04-01

    Measurement standards for pulmonary diffusing capacity were updated in 2005 by the ATS/ERS Task Force. However, in Finland reference values published in 1982 by Viljanen et al. have been used to date. The main aim of this study was to produce updated reference models for single-breath diffusing capacity for carbon monoxide for Finnish adults. Single-breath diffusing capacity for carbon monoxide was measured in 631 healthy non-smoking volunteers (41.5% male). Reference values for diffusing capacity (DLCO), alveolar volume (VA), diffusing capacity per unit of lung volume (DLCO/VA), and lung volumes were calculated using a linear regression model. Previously used Finnish reference values were found to produce too low predicted values, with mean predicted DLCO 111.0 and 104.4%, and DLCO/VA of 103.5 and 102.7% in males and females, respectively. With the European Coalition for Steel and Coal (ECSC) reference values there was a significant sex difference in DLCO/VA with mean predicted 105.4% in males and 92.8% in females (p < .001). New reference values for DLCO, DLCO/VA, VA, vital capacity (VC), inspiratory vital capacity (IVC), and inspiratory capacity (IC) are suggested for clinical use to replace technically outdated reference values for clinical applications.

  16. 77 FR 181 - Federal Acquisition Regulation; Federal Acquisition Circular 2005-55; Introduction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-03

    ... System. VI Updated Financial 2010-005 Chambers. Accounting Standards Board Accounting References. VII... Financial Accounting Standards Board Accounting References (FAR Case 2010-005) This final rule amends the... authoritative accounting standards owing to the Financial Accounting Standards Board's Accounting Standards...

  17. 10 CFR 50.150 - Aircraft impact assessment.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 13, 2009; (B) Renewal of standard design certifications in effect on July 13, 2009 which have not..., standard design approval, or manufactured reactor; or (B) Reference a standard design certification issued... certification or standard design approval; or (B) Reference a standard design certification issued before July...

  18. 10 CFR 50.150 - Aircraft impact assessment.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 13, 2009; (B) Renewal of standard design certifications in effect on July 13, 2009 which have not..., standard design approval, or manufactured reactor; or (B) Reference a standard design certification issued... certification or standard design approval; or (B) Reference a standard design certification issued before July...

  19. 10 CFR 50.150 - Aircraft impact assessment.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 13, 2009; (B) Renewal of standard design certifications in effect on July 13, 2009 which have not..., standard design approval, or manufactured reactor; or (B) Reference a standard design certification issued... certification or standard design approval; or (B) Reference a standard design certification issued before July...

  20. 10 CFR 50.150 - Aircraft impact assessment.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 13, 2009; (B) Renewal of standard design certifications in effect on July 13, 2009 which have not..., standard design approval, or manufactured reactor; or (B) Reference a standard design certification issued... certification or standard design approval; or (B) Reference a standard design certification issued before July...

  1. Efficient model learning methods for actor-critic control.

    PubMed

    Grondman, Ivo; Vaandrager, Maarten; Buşoniu, Lucian; Babuska, Robert; Schuitema, Erik

    2012-06-01

    We propose two new actor-critic algorithms for reinforcement learning. Both algorithms use local linear regression (LLR) to learn approximations of the functions involved. A crucial feature of the algorithms is that they also learn a process model, and this, in combination with LLR, provides an efficient policy update for faster learning. The first algorithm uses a novel model-based update rule for the actor parameters. The second algorithm does not use an explicit actor but learns a reference model which represents a desired behavior, from which desired control actions can be calculated using the inverse of the learned process model. The two novel methods and a standard actor-critic algorithm are applied to the pendulum swing-up problem, in which the novel methods achieve faster learning than the standard algorithm.

  2. Optical Fiber Power Meter Comparison Between NIST and NIM.

    PubMed

    Vayshenker, I; Livigni, D J; Li, X; Lehman, J H; Li, J; Xiong, L M; Zhang, Z X

    2010-01-01

    We describe the results of a comparison of reference standards between the National Institute of Standards and Technology (NIST-USA) and National Institute of Metrology (NIM-China). We report optical fiber-based power measurements at nominal wavelengths of 1310 nm and 1550 nm. We compare the laboratories' reference standards by means of a commercial optical power meter. Measurement results showed the largest difference of less than 2.6 parts in 10(3), which is within the combined standard (k = 1) uncertainty for the laboratories' reference standards.

  3. Towards a framework for developing semantic relatedness reference standards.

    PubMed

    Pakhomov, Serguei V S; Pedersen, Ted; McInnes, Bridget; Melton, Genevieve B; Ruggieri, Alexander; Chute, Christopher G

    2011-04-01

    Our objective is to develop a framework for creating reference standards for functional testing of computerized measures of semantic relatedness. Currently, research on computerized approaches to semantic relatedness between biomedical concepts relies on reference standards created for specific purposes using a variety of methods for their analysis. In most cases, these reference standards are not publicly available and the published information provided in manuscripts that evaluate computerized semantic relatedness measurement approaches is not sufficient to reproduce the results. Our proposed framework is based on the experiences of medical informatics and computational linguistics communities and addresses practical and theoretical issues with creating reference standards for semantic relatedness. We demonstrate the use of the framework on a pilot set of 101 medical term pairs rated for semantic relatedness by 13 medical coding experts. While the reliability of this particular reference standard is in the "moderate" range; we show that using clustering and factor analyses offers a data-driven approach to finding systematic differences among raters and identifying groups of potential outliers. We test two ontology-based measures of relatedness and provide both the reference standard containing individual ratings and the R program used to analyze the ratings as open-source. Currently, these resources are intended to be used to reproduce and compare results of studies involving computerized measures of semantic relatedness. Our framework may be extended to the development of reference standards in other research areas in medical informatics including automatic classification, information retrieval from medical records and vocabulary/ontology development. Copyright © 2010 Elsevier Inc. All rights reserved.

  4. Katja — the 24th week of virtual pregnancy for dosimetric calculations

    NASA Astrophysics Data System (ADS)

    Becker, Janine; Zankl, Maria; Fill, Ute; Hoeschen, Christoph

    2008-01-01

    Virtual human models, a.k.a. voxel models, are currently the state of the art in radiation protection for computing organ irradiation doses without difficult or morally unfeasible experiments. They are based on medical image data of human patients and offer a realistic, three dimensional representation of human anatomy. We present our newest voxel model Katja, a virtual woman in the 24th week of pregnancy. Katja integrates two previous voxel models, one obtained from the abdominal MRI scan of a pregnant patient and an already segmented model of a non-pregnant woman. The latter is the ICRP-AF, fitting the reference values for standard height, weight and organ masses given by the Internationals Committee of Radiological Protection (ICRP). The dataset was altered in order to fit the segmented foetus taken from the abdominal MRI scan. The resulting pregnant woman model, Katja, complies with the ICRP reference values for the adult female.

  5. Orbital-free bond breaking via machine learning

    NASA Astrophysics Data System (ADS)

    Snyder, John C.; Rupp, Matthias; Hansen, Katja; Blooston, Leo; Müller, Klaus-Robert; Burke, Kieron

    2013-12-01

    Using a one-dimensional model, we explore the ability of machine learning to approximate the non-interacting kinetic energy density functional of diatomics. This nonlinear interpolation between Kohn-Sham reference calculations can (i) accurately dissociate a diatomic, (ii) be systematically improved with increased reference data and (iii) generate accurate self-consistent densities via a projection method that avoids directions with no data. With relatively few densities, the error due to the interpolation is smaller than typical errors in standard exchange-correlation functionals.

  6. Toward uniform implementation of parametric map Digital Imaging and Communication in Medicine standard in multisite quantitative diffusion imaging studies.

    PubMed

    Malyarenko, Dariya; Fedorov, Andriy; Bell, Laura; Prah, Melissa; Hectors, Stefanie; Arlinghaus, Lori; Muzi, Mark; Solaiyappan, Meiyappan; Jacobs, Michael; Fung, Maggie; Shukla-Dave, Amita; McManus, Kevin; Boss, Michael; Taouli, Bachir; Yankeelov, Thomas E; Quarles, Christopher Chad; Schmainda, Kathleen; Chenevert, Thomas L; Newitt, David C

    2018-01-01

    This paper reports on results of a multisite collaborative project launched by the MRI subgroup of Quantitative Imaging Network to assess current capability and provide future guidelines for generating a standard parametric diffusion map Digital Imaging and Communication in Medicine (DICOM) in clinical trials that utilize quantitative diffusion-weighted imaging (DWI). Participating sites used a multivendor DWI DICOM dataset of a single phantom to generate parametric maps (PMs) of the apparent diffusion coefficient (ADC) based on two models. The results were evaluated for numerical consistency among models and true phantom ADC values, as well as for consistency of metadata with attributes required by the DICOM standards. This analysis identified missing metadata descriptive of the sources for detected numerical discrepancies among ADC models. Instead of the DICOM PM object, all sites stored ADC maps as DICOM MR objects, generally lacking designated attributes and coded terms for quantitative DWI modeling. Source-image reference, model parameters, ADC units and scale, deemed important for numerical consistency, were either missing or stored using nonstandard conventions. Guided by the identified limitations, the DICOM PM standard has been amended to include coded terms for the relevant diffusion models. Open-source software has been developed to support conversion of site-specific formats into the standard representation.

  7. 24 CFR 3285.406 - Flood hazard areas.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Flood hazard areas. 3285.406... URBAN DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Anchorage Against Wind § 3285.406 Flood hazard areas. Refer to § 3285.302 for anchoring requirements in flood hazard areas. ...

  8. High Energy Phenomenology - Proceedings of the Workshop

    NASA Astrophysics Data System (ADS)

    Pérez, Miguel A.; Huerta, Rodrigo

    1992-06-01

    The Table of Contents for the full book PDF is as follows: * Preface * Radiative Corrections in the Electroweak Standard Model * Introduction * The Electroweak Standard Model and its Renormalization * Basic Properties of the Standard Model * Renormalization of the Standard Model * Calculation of Radiative Corrections * One-Loop Integrals * Corrected Matrix Elements and Cross Sections * Photonic Corrections * Physical Applications and Results * Parameter Relations in Higher Orders * Decay Widths * Z Physics * W-Pair Production * Higgs Production in e+e- Annihilation * Conclusion * Appendix: Feynman Rules * References * Hadron Collider Physics * Introduction * e+ e- Annihilation * The Standard Model * The Drell-Yan Process in Hadronic Collisions * The Structure Functions * Hadronic Z Production * Hadronic W Production * The Transverse Mass * Quark Decays of W's * Weak Interactions * Neutrino Scattering * Weak Neutral Currents * The Standard Model * Symmetries and Lagrangians * Spontaneous Symmetry Breaking * The Standard Model Again * Experimental Situation * Appendix * References * Lectures on Heavy Quark Effective Theory * Introduction * Motivation * Physical Intuition * The Heavy Quark Effective Theory * The Effective Lagrangian and its Feynman Rules * What is an Effective Theory? * The Effective Theory Beyond Tree Level * External Currents * Leading-Logs or No Leading-Logs; A digression * Sample Calculations * Symmetries * Flavor-SU(N) * Spin-SU(2) * Spectrum * Strong Transitions * Covariant Representation of States * Meson Decay Constants * Preliminaries * Formal Derivation: Green Functions * Quick and Dirty Derivation: States in the HQET * Vector Meson Decay Constant * Corrections * Form Factors in overline {B} rightarrow Deν and overline {B} rightarrow D ^ast {e}ν * Preliminaries * Form Factors in the HQET * Form Factors in order αs * 1/MQ * The Correcting Lagrangian * The Corrected Currents * Corrections of order mc/mb * Corrections of order overline {Λ} /m_c and overline {Λ} /m_c * Conclusions and More * Inclusive Semileptonic Decay Rates * overline {B} rightarrow Π {e} overline {ν} and overline {B} rightarrow Π {e} overline {ν} * Rare overline {B} decays * e^+ e^- rightarrow {B} overline {B} * λb → λcDs vs λb → λc D*s * Factorization * A Last Word (or Two) * References * An Overview of Nonleptonic Decays of B, D, K Mesons and CP-Noninvariance * Generic Ways to Study Nonleptonic Decays and CP-Noninvariance * The Quark-Diagram Scheme * Invariants of the CKM and the Universal Decay-Amplitude CP-Noninvariance Factor Xcp * Implications of Measuring Partial-Decay-Rate Asymmetries in B± Decays and in Neutral B Decays such as B0, overline {B}^{0} rightarrow K_sJ/{Ψ} * Nonleptonic Decays of D Mesons: From the CKM Non- and Singly-Suppressed Decays to the Predictions of Doubly-Suppressed Decays * Charm Meson D Decays into Vector and Pseudoscalar Bosons, D → VP * Charm Meson Decays into Pseudoscalar-Pseudoscalar Mesons, D → PP * Charm Meson Decays into Vector-Vector Mesons, D → VV * Nonleptonic Decays of B Mesons * The CKM Non-Suppressed Decays * Interesting Features in the Rare B Meson Decays * CP-Noninvariance in K Meson Decays * Implications of Measurement of Re( ɛ'/ɛ) * Other Important Searches for Decay-Amplitude CP Noninvariance in Strange Particles * Some Generic Properties of Decay-Amplitude CP-Noninvariance * References * Top Quark Physics * Introduction * The Top Quark Exists * Upper Limit on Mt * Other Constraints on Mt * Production of Top * Hadron Colliders * SM Top Decays * Detecting SM Tops-Signatures * Model-Independent Lower Limit on Mt * Determining the Charge of a New Heavy Quark * When the Top Quark is Detected * Top Decays - A Window to New Physics? * - Decay to Supersymmetric Partners * - Decay to Charged Higgs Bosons * - Flavor-Changing Neutral Current Decays * - Other possibilities * New Information Once Top is Observed * Studying the Top Decays Couplings * The Top Quark at N LC * Measuring Mt - How Well? * Sharper Predictions for Many Observables * Measuring Vts, Vtd, Vtb and Γ(t → bW) * Top Polarization Predictions - A New Observable * Testing QCD Polarization Predictions * Correlation of Top Spin Direction with Final b, l+ Directions and Top Mass Measurements * Measuring P_{pm} ^ t * General Top Couplings * One Loop Corrections to Top Decay * Decay Helicity Amplitudes * New Sources of CP Violation at the Weak Scale? * The Effect of Top Loops on Higgs Masses * Is t → Wb a Background for Studying TeV WW Interactions? * Predictions for Mt * Final Remarks * References * High Precision Radiative Corrections in the Semileptonic Decays of Hyperons * On the Decay W± → P±γ * The Decay H0 → γγ and Physics Beyond the Standard Model * Neutrino Masses and Double Beta Decay * Neutrino Oscillations in a Medium: Analytic Calculation of Nonadiabatic Transitions * Gauge-Invariant Perturbation Theory Near a Gauge Resonance * Lower Dimensional Divergences in Gauge Theories * Strange Stars: Which is the Ground State of QCD at Finite Baryon Number? * Experimental Signatures of the SU(5)c Color Model * Generalized Supersymmetric Quantum Mechanics * Chern-Simons Theories in 2 + 1 Dimensions * List of participants

  9. 29 CFR 2703.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 9 2011-07-01 2011-07-01 false Cross-reference to employee ethical conduct standards and...-reference to employee ethical conduct standards and financial disclosure regulations. Members and employees... of Ethical Conduct at 5 CFR part 2635; the Commission's regulations at 5 CFR part 8401, which...

  10. 45 CFR 706.1 - Cross-references to employee ethical conduct standards, financial disclosure and financial...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 45 Public Welfare 3 2011-10-01 2011-10-01 false Cross-references to employee ethical conduct... EMPLOYEE RESPONSIBILITIES AND CONDUCT § 706.1 Cross-references to employee ethical conduct standards... States Commission on Civil Rights are subject to the executive branch standards of ethical conduct...

  11. 45 CFR 1105.1 - Cross-reference to employee ethical conduct standards and financial disclosure and financial...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 45 Public Welfare 3 2011-10-01 2011-10-01 false Cross-reference to employee ethical conduct... STANDARDS OF CONDUCT FOR EMPLOYEES § 1105.1 Cross-reference to employee ethical conduct standards and... ethical conduct at 5 CFR part 2635; the executive branch employees responsibilities and conduct...

  12. 49 CFR 99.735-1 - Cross-reference to ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 1 2011-10-01 2011-10-01 false Cross-reference to ethical conduct standards and... Transportation EMPLOYEE RESPONSIBILITIES AND CONDUCT General § 99.735-1 Cross-reference to ethical conduct... the executive branch-wide Standards of Ethical Conduct at 5 CFR part 2635, the Department of...

  13. 39 CFR 3000.735-101 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 39 Postal Service 1 2011-07-01 2011-07-01 false Cross-reference to employee ethical conduct... employee ethical conduct standards and financial disclosure regulations. Employees of the Postal Regulatory Commission (Commission) are subject and should refer to the executive branch-wide Standards of Ethical...

  14. 45 CFR 706.1 - Cross-references to employee ethical conduct standards, financial disclosure and financial...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 45 Public Welfare 3 2010-10-01 2010-10-01 false Cross-references to employee ethical conduct... EMPLOYEE RESPONSIBILITIES AND CONDUCT § 706.1 Cross-references to employee ethical conduct standards... States Commission on Civil Rights are subject to the executive branch standards of ethical conduct...

  15. 45 CFR 1105.1 - Cross-reference to employee ethical conduct standards and financial disclosure and financial...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 45 Public Welfare 3 2010-10-01 2010-10-01 false Cross-reference to employee ethical conduct... STANDARDS OF CONDUCT FOR EMPLOYEES § 1105.1 Cross-reference to employee ethical conduct standards and... ethical conduct at 5 CFR part 2635; the executive branch employees responsibilities and conduct...

  16. 49 CFR 99.735-1 - Cross-reference to ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false Cross-reference to ethical conduct standards and... Transportation EMPLOYEE RESPONSIBILITIES AND CONDUCT General § 99.735-1 Cross-reference to ethical conduct... the executive branch-wide Standards of Ethical Conduct at 5 CFR part 2635, the Department of...

  17. 39 CFR 3000.735-101 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Cross-reference to employee ethical conduct... employee ethical conduct standards and financial disclosure regulations. Employees of the Postal Regulatory Commission (Commission) are subject and should refer to the executive branch-wide Standards of Ethical...

  18. 29 CFR 2703.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 9 2010-07-01 2010-07-01 false Cross-reference to employee ethical conduct standards and...-reference to employee ethical conduct standards and financial disclosure regulations. Members and employees... of Ethical Conduct at 5 CFR part 2635; the Commission's regulations at 5 CFR part 8401, which...

  19. 29 CFR 2703.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 29 Labor 9 2013-07-01 2013-07-01 false Cross-reference to employee ethical conduct standards and...-reference to employee ethical conduct standards and financial disclosure regulations. Members and employees... of Ethical Conduct at 5 CFR part 2635; the Commission's regulations at 5 CFR part 8401, which...

  20. 49 CFR 99.735-1 - Cross-reference to ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 1 2013-10-01 2013-10-01 false Cross-reference to ethical conduct standards and... Transportation EMPLOYEE RESPONSIBILITIES AND CONDUCT General § 99.735-1 Cross-reference to ethical conduct... the executive branch-wide Standards of Ethical Conduct at 5 CFR part 2635, the Department of...

  1. 16 CFR § 1030.101 - Cross-references to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 16 Commercial Practices 2 2013-01-01 2013-01-01 false Cross-references to employee ethical conduct...-references to employee ethical conduct standards and financial disclosure regulations. Employees of the Consumer Product Safety Commission are subject to the Standards of Ethical Conduct, 5 CFR part 2635, which...

  2. 45 CFR 706.1 - Cross-references to employee ethical conduct standards, financial disclosure and financial...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 45 Public Welfare 3 2012-10-01 2012-10-01 false Cross-references to employee ethical conduct... EMPLOYEE RESPONSIBILITIES AND CONDUCT § 706.1 Cross-references to employee ethical conduct standards... States Commission on Civil Rights are subject to the executive branch standards of ethical conduct...

  3. 49 CFR 99.735-1 - Cross-reference to ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 1 2014-10-01 2014-10-01 false Cross-reference to ethical conduct standards and... Transportation EMPLOYEE RESPONSIBILITIES AND CONDUCT General § 99.735-1 Cross-reference to ethical conduct... the executive branch-wide Standards of Ethical Conduct at 5 CFR part 2635, the Department of...

  4. 45 CFR 1105.1 - Cross-reference to employee ethical conduct standards and financial disclosure and financial...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 45 Public Welfare 3 2012-10-01 2012-10-01 false Cross-reference to employee ethical conduct... STANDARDS OF CONDUCT FOR EMPLOYEES § 1105.1 Cross-reference to employee ethical conduct standards and... ethical conduct at 5 CFR part 2635; the executive branch employees responsibilities and conduct...

  5. 29 CFR 2703.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 29 Labor 9 2014-07-01 2014-07-01 false Cross-reference to employee ethical conduct standards and...-reference to employee ethical conduct standards and financial disclosure regulations. Members and employees... of Ethical Conduct at 5 CFR part 2635; the Commission's regulations at 5 CFR part 8401, which...

  6. 39 CFR 3000.735-101 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 39 Postal Service 1 2013-07-01 2013-07-01 false Cross-reference to employee ethical conduct... employee ethical conduct standards and financial disclosure regulations. Employees of the Postal Regulatory Commission (Commission) are subject and should refer to the executive branch-wide Standards of Ethical...

  7. 39 CFR 3000.735-101 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 39 Postal Service 1 2012-07-01 2012-07-01 false Cross-reference to employee ethical conduct... employee ethical conduct standards and financial disclosure regulations. Employees of the Postal Regulatory Commission (Commission) are subject and should refer to the executive branch-wide Standards of Ethical...

  8. 45 CFR 1105.1 - Cross-reference to employee ethical conduct standards and financial disclosure and financial...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 45 Public Welfare 3 2013-10-01 2013-10-01 false Cross-reference to employee ethical conduct... STANDARDS OF CONDUCT FOR EMPLOYEES § 1105.1 Cross-reference to employee ethical conduct standards and... ethical conduct at 5 CFR part 2635; the executive branch employees responsibilities and conduct...

  9. 29 CFR 2703.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 9 2012-07-01 2012-07-01 false Cross-reference to employee ethical conduct standards and...-reference to employee ethical conduct standards and financial disclosure regulations. Members and employees... of Ethical Conduct at 5 CFR part 2635; the Commission's regulations at 5 CFR part 8401, which...

  10. 45 CFR 1105.1 - Cross-reference to employee ethical conduct standards and financial disclosure and financial...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 45 Public Welfare 3 2014-10-01 2014-10-01 false Cross-reference to employee ethical conduct... STANDARDS OF CONDUCT FOR EMPLOYEES § 1105.1 Cross-reference to employee ethical conduct standards and... ethical conduct at 5 CFR part 2635; the executive branch employees responsibilities and conduct...

  11. 39 CFR 3000.735-101 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 39 Postal Service 1 2014-07-01 2014-07-01 false Cross-reference to employee ethical conduct... employee ethical conduct standards and financial disclosure regulations. Employees of the Postal Regulatory Commission (Commission) are subject and should refer to the executive branch-wide Standards of Ethical...

  12. 45 CFR 706.1 - Cross-references to employee ethical conduct standards, financial disclosure and financial...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 45 Public Welfare 3 2013-10-01 2013-10-01 false Cross-references to employee ethical conduct... EMPLOYEE RESPONSIBILITIES AND CONDUCT § 706.1 Cross-references to employee ethical conduct standards... States Commission on Civil Rights are subject to the executive branch standards of ethical conduct...

  13. 45 CFR 706.1 - Cross-references to employee ethical conduct standards, financial disclosure and financial...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 45 Public Welfare 3 2014-10-01 2014-10-01 false Cross-references to employee ethical conduct... EMPLOYEE RESPONSIBILITIES AND CONDUCT § 706.1 Cross-references to employee ethical conduct standards... States Commission on Civil Rights are subject to the executive branch standards of ethical conduct...

  14. 49 CFR 99.735-1 - Cross-reference to ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 1 2012-10-01 2012-10-01 false Cross-reference to ethical conduct standards and... Transportation EMPLOYEE RESPONSIBILITIES AND CONDUCT General § 99.735-1 Cross-reference to ethical conduct... the executive branch-wide Standards of Ethical Conduct at 5 CFR part 2635, the Department of...

  15. SHORT COMMUNICATION: Transportable Zener-diode Voltage Standard

    NASA Astrophysics Data System (ADS)

    Karpov, O. V.; Shulga, V. M.; Shakirzyanova, F. R.; Sarandi, A. E.

    1994-01-01

    Five transportable Zener-diode dc voltage standards have been developed, fabricated and investigated at the NPO VNIIFTRI. The standards were designed to transfer the unit of electromotive force (emf) from Josephson reference standards to measuring instruments. Following the results of these investigations, standard N 02 has been used for intercomparison of the Russian Josephson reference standards.

  16. The Effect of Electroencephalogram (EEG) Reference Choice on Information-Theoretic Measures of the Complexity and Integration of EEG Signals

    PubMed Central

    Trujillo, Logan T.; Stanfield, Candice T.; Vela, Ruben D.

    2017-01-01

    Converging evidence suggests that human cognition and behavior emerge from functional brain networks interacting on local and global scales. We investigated two information-theoretic measures of functional brain segregation and integration—interaction complexity CI(X), and integration I(X)—as applied to electroencephalographic (EEG) signals and how these measures are affected by choice of EEG reference. CI(X) is a statistical measure of the system entropy accounted for by interactions among its elements, whereas I(X) indexes the overall deviation from statistical independence of the individual elements of a system. We recorded 72 channels of scalp EEG from human participants who sat in a wakeful resting state (interleaved counterbalanced eyes-open and eyes-closed blocks). CI(X) and I(X) of the EEG signals were computed using four different EEG references: linked-mastoids (LM) reference, average (AVG) reference, a Laplacian (LAP) “reference-free” transformation, and an infinity (INF) reference estimated via the Reference Electrode Standardization Technique (REST). Fourier-based power spectral density (PSD), a standard measure of resting state activity, was computed for comparison and as a check of data integrity and quality. We also performed dipole source modeling in order to assess the accuracy of neural source CI(X) and I(X) estimates obtained from scalp-level EEG signals. CI(X) was largest for the LAP transformation, smallest for the LM reference, and at intermediate values for the AVG and INF references. I(X) was smallest for the LAP transformation, largest for the LM reference, and at intermediate values for the AVG and INF references. Furthermore, across all references, CI(X) and I(X) reliably distinguished between resting-state conditions (larger values for eyes-open vs. eyes-closed). These findings occurred in the context of the overall expected pattern of resting state PSD. Dipole modeling showed that simulated scalp EEG-level CI(X) and I(X) reflected changes in underlying neural source dependencies, but only for higher levels of integration and with highest accuracy for the LAP transformation. Our observations suggest that the Laplacian-transformation should be preferred for the computation of scalp-level CI(X) and I(X) due to its positive impact on EEG signal quality and statistics, reduction of volume-conduction, and the higher accuracy this provides when estimating scalp-level EEG complexity and integration. PMID:28790884

  17. 77 FR 205 - Federal Acquisition Regulation; Federal Acquisition Circular 2005-55; Small Entity Compliance Guide

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-03

    ... System. VI Updated Financial 2010-005 Chambers. Accounting Standards Board Accounting References. VII... Financial Accounting Standards Board Accounting References (FAR Case 2010-005) This final rule amends the... authoritative accounting standards owing to the Financial Accounting Standards Board's Accounting Standards...

  18. Current issues with standards in the measurement and documentation of human skeletal anatomy.

    PubMed

    Magee, Justin; McClelland, Brian; Winder, John

    2012-09-01

    Digital modeling of human anatomy has become increasingly important and relies on well-documented quantitative anatomy literature. This type of documentation is common for the spine and pelvis; however, significant issues exist due to the lack of standardization in measurement and technique. Existing literature on quantitative anatomy for the spine and pelvis of white adults (aged 18-65 years, separated into decadal categories) was reviewed from the disciplines of anatomy, manipulative therapy, anthropometrics, occupational ergonomics, biomechanics and forensic science. The data were unified into a single normative model of the sub-axial spine. Two-dimensional orthographic drawings were produced from the 590 individual measurements identified, which informed the development of a 3D digital model. A similar review of full range of motion data was conducted as a meta-analysis and the results were applied to the existing model, providing an inter-connected, articulated digital spine. During these data analysis processes several inconsistencies were observed accompanied by an evidential lack of standardization with measurement and recording of data. These have been categorized as: anatomical terminology; scaling of measurements; measurement methodology, dimension and anatomical reference positions; global coordinate systems. There is inconsistency in anatomical terminology where independent researchers use the same terms to describe different aspects of anatomy or different terms for the same anatomy. Published standards exist for measurement methods of the human body regarding spatial interaction, anthropometric databases, automotive applications, clothing industries and for computer manikins, but none exists for skeletal anatomy. Presentation of measurements often lacks formal structure in clinical publications, seldom providing geometric reference points, therefore making digital reconstruction difficult. Published quantitative data does not follow existing international published standards relating to engineering drawing and visual communication. Large variations are also evident in standards or guidelines used for global coordinate systems across biomechanics, ergonomics, software systems and 3D software applications. This paper identifies where established good practice exists and suggests additional recommendations, informing an improved communication protocol, to assist reconstruction of skeletal anatomy using 3D digital modeling. © 2012 The Authors. Journal of Anatomy © 2012 Anatomical Society.

  19. Current issues with standards in the measurement and documentation of human skeletal anatomy

    PubMed Central

    Magee, Justin; McClelland, Brian; Winder, John

    2012-01-01

    Digital modeling of human anatomy has become increasingly important and relies on well-documented quantitative anatomy literature. This type of documentation is common for the spine and pelvis; however, significant issues exist due to the lack of standardization in measurement and technique. Existing literature on quantitative anatomy for the spine and pelvis of white adults (aged 18–65 years, separated into decadal categories) was reviewed from the disciplines of anatomy, manipulative therapy, anthropometrics, occupational ergonomics, biomechanics and forensic science. The data were unified into a single normative model of the sub-axial spine. Two-dimensional orthographic drawings were produced from the 590 individual measurements identified, which informed the development of a 3D digital model. A similar review of full range of motion data was conducted as a meta-analysis and the results were applied to the existing model, providing an inter-connected, articulated digital spine. During these data analysis processes several inconsistencies were observed accompanied by an evidential lack of standardization with measurement and recording of data. These have been categorized as: anatomical terminology; scaling of measurements; measurement methodology, dimension and anatomical reference positions; global coordinate systems. There is inconsistency in anatomical terminology where independent researchers use the same terms to describe different aspects of anatomy or different terms for the same anatomy. Published standards exist for measurement methods of the human body regarding spatial interaction, anthropometric databases, automotive applications, clothing industries and for computer manikins, but none exists for skeletal anatomy. Presentation of measurements often lacks formal structure in clinical publications, seldom providing geometric reference points, therefore making digital reconstruction difficult. Published quantitative data does not follow existing international published standards relating to engineering drawing and visual communication. Large variations are also evident in standards or guidelines used for global coordinate systems across biomechanics, ergonomics, software systems and 3D software applications. This paper identifies where established good practice exists and suggests additional recommendations, informing an improved communication protocol, to assist reconstruction of skeletal anatomy using 3D digital modeling. PMID:22747678

  20. The CAFE Experiment: A Joint Seismic and MT Investigation of the Cascadia Subduction System

    DTIC Science & Technology

    2013-02-01

    In this thesis we present results from inversion of data using dense arrays of collocated seismic and magnetotelluric stations located in the Cascadia...implicit in the standard MT inversion provides tools that enable us to generate a more accurate MT model. This final MT model clearly demonstrates...references within, Hacker, 2008) have given us the tools to better interpret geophysical evidence. Improvements in the thermal modeling of subduction zones

  1. Use of Fat Mass and Fat Free Mass Standard Deviation Scores Obtained Using Simple Measurement Methods in Healthy Children and Patients: Comparison with the Reference 4-Component Model

    PubMed Central

    Atherton, Rachel R.; Williams, Jane E.; Wells, Jonathan C. K.; Fewtrell, Mary S.

    2013-01-01

    Background Clinical application of body composition (BC) measurements for individual children has been limited by lack of appropriate reference data. Objectives (1) To compare fat mass (FM) and fat free mass (FFM) standard deviation scores (SDS) generated using new body composition reference data and obtained using simple measurement methods in healthy children and patients with those obtained using the reference 4-component (4-C) model; (2) To determine the extent to which scores from simple methods agree with those from the 4-C model in identification of abnormal body composition. Design FM SDS were calculated for 4-C model, dual-energy X-ray absorptiometry (DXA; GE Lunar Prodigy), BMI and skinfold thicknesses (SFT); and FFM SDS for 4CM, DXA and bioelectrical impedance analysis (BIA; height2/Z)) in 927 subjects aged 3.8–22.0 y (211 healthy, 716 patients). Results DXA was the most accurate method for both FM and FFM SDS in healthy subjects and patients (mean bias (limits of agreement) FM SDS 0.03 (±0.62); FFM SDS −0.04 (±0.72)), and provided best agreement with the 4-C model in identifying abnormal BC (SDS ≤−2 or ≥2). BMI and SFTs were reasonable predictors of abnormal FM SDS, but poor in providing an absolute value. BIA was comparable to DXA for FFM SDS and in identifying abnormal subjects. Conclusions DXA may be used both for research and clinically to determine FM and FFM SDS. BIA may be used to assess FFM SDS in place of DXA. BMI and SFTs can be used to measure adiposity for groups but not individuals. The performance of simpler techniques in monitoring longitudinal BC changes requires investigation. Ultimately, the most appropriate method should be determined by its predictive value for clinical outcome. PMID:23690932

  2. Use of fat mass and fat free mass standard deviation scores obtained using simple measurement methods in healthy children and patients: comparison with the reference 4-component model.

    PubMed

    Atherton, Rachel R; Williams, Jane E; Wells, Jonathan C K; Fewtrell, Mary S

    2013-01-01

    Clinical application of body composition (BC) measurements for individual children has been limited by lack of appropriate reference data. (1) To compare fat mass (FM) and fat free mass (FFM) standard deviation scores (SDS) generated using new body composition reference data and obtained using simple measurement methods in healthy children and patients with those obtained using the reference 4-component (4-C) model; (2) To determine the extent to which scores from simple methods agree with those from the 4-C model in identification of abnormal body composition. FM SDS were calculated for 4-C model, dual-energy X-ray absorptiometry (DXA; GE Lunar Prodigy), BMI and skinfold thicknesses (SFT); and FFM SDS for 4CM, DXA and bioelectrical impedance analysis (BIA; height(2)/Z)) in 927 subjects aged 3.8-22.0 y (211 healthy, 716 patients). DXA was the most accurate method for both FM and FFM SDS in healthy subjects and patients (mean bias (limits of agreement) FM SDS 0.03 (± 0.62); FFM SDS -0.04 (± 0.72)), and provided best agreement with the 4-C model in identifying abnormal BC (SDS ≤-2 or ≥ 2). BMI and SFTs were reasonable predictors of abnormal FM SDS, but poor in providing an absolute value. BIA was comparable to DXA for FFM SDS and in identifying abnormal subjects. DXA may be used both for research and clinically to determine FM and FFM SDS. BIA may be used to assess FFM SDS in place of DXA. BMI and SFTs can be used to measure adiposity for groups but not individuals. The performance of simpler techniques in monitoring longitudinal BC changes requires investigation. Ultimately, the most appropriate method should be determined by its predictive value for clinical outcome.

  3. Archetype Model-Driven Development Framework for EHR Web System.

    PubMed

    Kobayashi, Shinji; Kimura, Eizen; Ishihara, Ken

    2013-12-01

    This article describes the Web application framework for Electronic Health Records (EHRs) we have developed to reduce construction costs for EHR sytems. The openEHR project has developed clinical model driven architecture for future-proof interoperable EHR systems. This project provides the specifications to standardize clinical domain model implementations, upon which the ISO/CEN 13606 standards are based. The reference implementation has been formally described in Eiffel. Moreover C# and Java implementations have been developed as reference. While scripting languages had been more popular because of their higher efficiency and faster development in recent years, they had not been involved in the openEHR implementations. From 2007, we have used the Ruby language and Ruby on Rails (RoR) as an agile development platform to implement EHR systems, which is in conformity with the openEHR specifications. We implemented almost all of the specifications, the Archetype Definition Language parser, and RoR scaffold generator from archetype. Although some problems have emerged, most of them have been resolved. We have provided an agile EHR Web framework, which can build up Web systems from archetype models using RoR. The feasibility of the archetype model to provide semantic interoperability of EHRs has been demonstrated and we have verified that that it is suitable for the construction of EHR systems.

  4. Integration of implant planning workflows into the PACS infrastructure

    NASA Astrophysics Data System (ADS)

    Gessat, Michael; Strauß, Gero; Burgert, Oliver

    2008-03-01

    The integration of imaging devices, diagnostic workstations, and image servers into Picture Archiving and Communication Systems (PACS) has had an enormous effect on the efficiency of radiology workflows. The standardization of the information exchange between the devices with the DICOM standard has been an essential precondition for that development. For surgical procedures, no such infrastructure exists. With the increasingly important role computerized planning and assistance systems play in the surgical domain, an infrastructure that unifies the communication between devices becomes necessary. In recent publications, the need for a modularized system design has been established. A reference architecture for a Therapy Imaging and Model Management System (TIMMS) has been proposed. It was accepted by the DICOM Working Group 6 as the reference architecture for DICOM developments for surgery. In this paper we propose the inclusion of implant planning systems into the PACS infrastructure. We propose a generic information model for the patient specific selection and positioning of implants from a repository according to patient image data. The information models are based on clinical workflows from ENT, cardiac, and orthopedic surgery as well as technical requirements derived from different use cases and systems. We show an exemplary implementation of the model for application in ENT surgery: the selection and positioning of an ossicular implant in the middle ear. An implant repository is stored in the PACS. It makes use of an experimental implementation of the Surface Mesh Module that is currently being developed as extension to the DICOM standard.

  5. Automatic summary generating technology of vegetable traceability for information sharing

    NASA Astrophysics Data System (ADS)

    Zhenxuan, Zhang; Minjing, Peng

    2017-06-01

    In order to solve problems of excessive data entries and consequent high costs for data collection in vegetable traceablility for farmers in traceability applications, the automatic summary generating technology of vegetable traceability for information sharing was proposed. The proposed technology is an effective way for farmers to share real-time vegetable planting information in social networking platforms to enhance their brands and obtain more customers. In this research, the influencing factors in the vegetable traceablility for customers were analyzed to establish the sub-indicators and target indicators and propose a computing model based on the collected parameter values of the planted vegetables and standard legal systems on food safety. The proposed standard parameter model involves five steps: accessing database, establishing target indicators, establishing sub-indicators, establishing standard reference model and computing scores of indicators. On the basis of establishing and optimizing the standards of food safety and traceability system, this proposed technology could be accepted by more and more farmers and customers.

  6. 15 CFR 200.104 - Standard reference materials.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... the NIST National Measurement Laboratory administers a program to provide many types of well... be readily referred to a common base. NIST SP 260 is a catalog of Standard Reference Materials available from NIST. ...

  7. 15 CFR 200.104 - Standard reference materials.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... the NIST National Measurement Laboratory administers a program to provide many types of well... be readily referred to a common base. NIST SP 260 is a catalog of Standard Reference Materials available from NIST. ...

  8. 15 CFR 200.104 - Standard reference materials.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... the NIST National Measurement Laboratory administers a program to provide many types of well... be readily referred to a common base. NIST SP 260 is a catalog of Standard Reference Materials available from NIST. ...

  9. 15 CFR 200.104 - Standard reference materials.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... the NIST National Measurement Laboratory administers a program to provide many types of well... be readily referred to a common base. NIST SP 260 is a catalog of Standard Reference Materials available from NIST. ...

  10. 15 CFR 200.104 - Standard reference materials.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... the NIST National Measurement Laboratory administers a program to provide many types of well... be readily referred to a common base. NIST SP 260 is a catalog of Standard Reference Materials available from NIST. ...

  11. Coherent Frequency Reference System for the NASA Deep Space Network

    NASA Technical Reports Server (NTRS)

    Tucker, Blake C.; Lauf, John E.; Hamell, Robert L.; Gonzaler, Jorge, Jr.; Diener, William A.; Tjoelker, Robert L.

    2010-01-01

    The NASA Deep Space Network (DSN) requires state-of-the-art frequency references that are derived and distributed from very stable atomic frequency standards. A new Frequency Reference System (FRS) and Frequency Reference Distribution System (FRD) have been developed, which together replace the previous Coherent Reference Generator System (CRG). The FRS and FRD each provide new capabilities that significantly improve operability and reliability. The FRS allows for selection and switching between frequency standards, a flywheel capability (to avoid interruptions when switching frequency standards), and a frequency synthesis system (to generate standardized 5-, 10-, and 100-MHz reference signals). The FRS is powered by redundant, specially filtered, and sustainable power systems and includes a monitor and control capability for station operations to interact and control the frequency-standard selection process. The FRD receives the standardized 5-, 10-, and 100-MHz reference signals and distributes signals to distribution amplifiers in a fan out fashion to dozens of DSN users that require the highly stable reference signals. The FRD is also powered by redundant, specially filtered, and sustainable power systems. The new DSN Frequency Distribution System, which consists of the FRS and FRD systems described here, is central to all operational activities of the NASA DSN. The frequency generation and distribution system provides ultra-stable, coherent, and very low phase-noise references at 5, l0, and 100 MHz to between 60 and 100 separate users at each Deep Space Communications Complex.

  12. Making Organisms Model Human Behavior: Situated Models in North-American Alcohol Research, 1950-onwards

    PubMed Central

    Leonelli, Sabina; Ankeny, Rachel A.; Nelson, Nicole C.; Ramsden, Edmund

    2014-01-01

    Argument We examine the criteria used to validate the use of nonhuman organisms in North-American alcohol addiction research from the 1950s to the present day. We argue that this field, where the similarities between behaviors in humans and non-humans are particularly difficult to assess, has addressed questions of model validity by transforming the situatedness of non-human organisms into an experimental tool. We demonstrate that model validity does not hinge on the standardization of one type of organism in isolation, as often the case with genetic model organisms. Rather, organisms are viewed as necessarily situated: they cannot be understood as a model for human behavior in isolation from their environmental conditions. Hence the environment itself is standardized as part of the modeling process; and model validity is assessed with reference to the environmental conditions under which organisms are studied. PMID:25233743

  13. Improving Atomic Force Microscopy Imaging by a Direct Inverse Asymmetric PI Hysteresis Model

    PubMed Central

    Wang, Dong; Yu, Peng; Wang, Feifei; Chan, Ho-Yin; Zhou, Lei; Dong, Zaili; Liu, Lianqing; Li, Wen Jung

    2015-01-01

    A modified Prandtl–Ishlinskii (PI) model, referred to as a direct inverse asymmetric PI (DIAPI) model in this paper, was implemented to reduce the displacement error between a predicted model and the actual trajectory of a piezoelectric actuator which is commonly found in AFM systems. Due to the nonlinearity of the piezoelectric actuator, the standard symmetric PI model cannot precisely describe the asymmetric motion of the actuator. In order to improve the accuracy of AFM scans, two series of slope parameters were introduced in the PI model to describe both the voltage-increase-loop (trace) and voltage-decrease-loop (retrace). A feedforward controller based on the DIAPI model was implemented to compensate hysteresis. Performance of the DIAPI model and the feedforward controller were validated by scanning micro-lenses and standard silicon grating using a custom-built AFM. PMID:25654719

  14. Laboratory methodologies for indicators of iron status: strengths, limitations, and analytical challenges.

    PubMed

    Pfeiffer, Christine M; Looker, Anne C

    2017-12-01

    Biochemical assessment of iron status relies on serum-based indicators, such as serum ferritin (SF), transferrin saturation, and soluble transferrin receptor (sTfR), as well as erythrocyte protoporphyrin. These indicators present challenges for clinical practice and national nutrition surveys, and often iron status interpretation is based on the combination of several indicators. The diagnosis of iron deficiency (ID) through SF concentration, the most commonly used indicator, is complicated by concomitant inflammation. sTfR concentration is an indicator of functional ID that is not an acute-phase reactant, but challenges in its interpretation arise because of the lack of assay standardization, common reference ranges, and common cutoffs. It is unclear which indicators are best suited to assess excess iron status. The value of hepcidin, non-transferrin-bound iron, and reticulocyte indexes is being explored in research settings. Serum-based indicators are generally measured on fully automated clinical analyzers available in most hospitals. Although international reference materials have been available for years, the standardization of immunoassays is complicated by the heterogeneity of antibodies used and the absence of physicochemical reference methods to establish "true" concentrations. From 1988 to 2006, the assessment of iron status in NHANES was based on the multi-indicator ferritin model. However, the model did not indicate the severity of ID and produced categorical estimates. More recently, iron status assessment in NHANES has used the total body iron stores (TBI) model, in which the log ratio of sTfR to SF is assessed. Together, sTfR and SF concentrations cover the full range of iron status. The TBI model better predicts the absence of bone marrow iron than SF concentration alone, and TBI can be analyzed as a continuous variable. Additional consideration of methodologies, interpretation of indicators, and analytic standardization is important for further improvements in iron status assessment. © 2017 American Society for Nutrition.

  15. Monitoring for airborne allergens

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burge, H.A.

    1992-07-01

    Monitoring for allergens can provide some information on the kinds and levels of exposure experienced by local patient populations, providing volumetric methods are used for sample collection and analysis is accurate and consistent. Such data can also be used to develop standards for the specific environment and to begin to develop predictive models. Comparing outdoor allergen aerosols between different monitoring sites requires identical collection and analysis methods and some kind of rational standard, whether arbitrary, or based on recognized health effects.32 references.

  16. Biophysical characterization and structure of the Fab fragment from the NIST reference antibody, RM 8671.

    PubMed

    Karageorgos, Ioannis; Gallagher, Elyssia S; Galvin, Connor; Gallagher, D Travis; Hudgens, Jeffrey W

    2017-11-01

    Monoclonal antibody pharmaceuticals are the fastest-growing class of therapeutics, with a wide range of clinical applications. To assure their safety, these protein drugs must demonstrate highly consistent purity and stability. Key to these objectives is higher order structure measurements validated by calibration to reference materials. We describe preparation, characterization, and crystal structure of the Fab fragment prepared from the NIST Reference Antibody RM 8671 (NISTmAb). NISTmAb is a humanized IgG1κ antibody, produced in murine cell culture and purified by standard biopharmaceutical production methods, developed at the National Institute of Standards and Technology (NIST) to serve as a reference material. The Fab fragment was derived from NISTmAb through papain cleavage followed by protein A based purification. The purified Fab fragment was characterized by SDS-PAGE, capillary gel electrophoresis, multi-angle light scattering, size exclusion chromatography, mass spectrometry, and x-ray crystallography. The crystal structure at 0.2 nm resolution includes four independent Fab molecules with complete light chains and heavy chains through Cys 223, enabling assessment of conformational variability and providing a well-characterized reference structure for research and engineering applications. This nonproprietary, publically available reference material of known higher-order structure can support metrology in biopharmaceutical applications, and it is a suitable platform for validation of molecular modeling studies. Published by Elsevier Ltd.

  17. 12 CFR 336.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 12 Banks and Banking 4 2011-01-01 2011-01-01 false Cross-reference to employee ethical conduct... and Conduct § 336.1 Cross-reference to employee ethical conduct standards and financial disclosure... Branch-wide Standards of Ethical Conduct at 5 CFR part 2635, the Corporation regulation at 5 CFR part...

  18. 12 CFR 264.101 - Cross-reference to employees' ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 12 Banks and Banking 3 2011-01-01 2011-01-01 false Cross-reference to employees' ethical conduct... § 264.101 Cross-reference to employees' ethical conduct standards and financial disclosure regulations... branch-wide standards of ethical conduct at 5 CFR part 2635 and the Board's regulation at 5 CFR part 6801...

  19. 10 CFR 1010.102 - Cross-references to employee ethical conduct standards, financial disclosure regulations, and...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Cross-references to employee ethical conduct standards... ENERGY (GENERAL PROVISIONS) CONDUCT OF EMPLOYEES § 1010.102 Cross-references to employee ethical conduct... Standards of Ethical Conduct for Employees of the Executive Branch at 5 CFR part 2635, the DOE regulation at...

  20. 12 CFR 336.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 4 2010-01-01 2010-01-01 false Cross-reference to employee ethical conduct... and Conduct § 336.1 Cross-reference to employee ethical conduct standards and financial disclosure... Branch-wide Standards of Ethical Conduct at 5 CFR part 2635, the Corporation regulation at 5 CFR part...

  1. 12 CFR 264.101 - Cross-reference to employees' ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 3 2010-01-01 2010-01-01 false Cross-reference to employees' ethical conduct... § 264.101 Cross-reference to employees' ethical conduct standards and financial disclosure regulations... branch-wide standards of ethical conduct at 5 CFR part 2635 and the Board's regulation at 5 CFR part 6801...

  2. 12 CFR 264.101 - Cross-reference to employees' ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 12 Banks and Banking 4 2012-01-01 2012-01-01 false Cross-reference to employees' ethical conduct... AND CONDUCT § 264.101 Cross-reference to employees' ethical conduct standards and financial disclosure... executive branch-wide standards of ethical conduct at 5 CFR part 2635 and the Board's regulation at 5 CFR...

  3. 12 CFR 264.101 - Cross-reference to employees' ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 12 Banks and Banking 4 2014-01-01 2014-01-01 false Cross-reference to employees' ethical conduct... AND CONDUCT § 264.101 Cross-reference to employees' ethical conduct standards and financial disclosure... executive branch-wide standards of ethical conduct at 5 CFR part 2635 and the Board's regulation at 5 CFR...

  4. 12 CFR 336.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 12 Banks and Banking 5 2014-01-01 2014-01-01 false Cross-reference to employee ethical conduct... and Conduct § 336.1 Cross-reference to employee ethical conduct standards and financial disclosure... Branch-wide Standards of Ethical Conduct at 5 CFR part 2635, the Corporation regulation at 5 CFR part...

  5. 12 CFR 336.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 12 Banks and Banking 5 2013-01-01 2013-01-01 false Cross-reference to employee ethical conduct... and Conduct § 336.1 Cross-reference to employee ethical conduct standards and financial disclosure... Branch-wide Standards of Ethical Conduct at 5 CFR part 2635, the Corporation regulation at 5 CFR part...

  6. 12 CFR 336.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 12 Banks and Banking 5 2012-01-01 2012-01-01 false Cross-reference to employee ethical conduct... and Conduct § 336.1 Cross-reference to employee ethical conduct standards and financial disclosure... Branch-wide Standards of Ethical Conduct at 5 CFR part 2635, the Corporation regulation at 5 CFR part...

  7. 12 CFR 264.101 - Cross-reference to employees' ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 12 Banks and Banking 4 2013-01-01 2013-01-01 false Cross-reference to employees' ethical conduct... AND CONDUCT § 264.101 Cross-reference to employees' ethical conduct standards and financial disclosure... executive branch-wide standards of ethical conduct at 5 CFR part 2635 and the Board's regulation at 5 CFR...

  8. 24 CFR 3285.104 - Moving manufactured home to location.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 5 2013-04-01 2013-04-01 false Moving manufactured home to... HOUSING AND URBAN DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Pre-Installation Considerations § 3285.104 Moving manufactured home to location. Refer to § 3285.902 for considerations related to...

  9. 24 CFR 3285.104 - Moving manufactured home to location.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 5 2011-04-01 2011-04-01 false Moving manufactured home to... HOUSING AND URBAN DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Pre-Installation Considerations § 3285.104 Moving manufactured home to location. Refer to § 3285.902 for considerations related to...

  10. 24 CFR 3285.104 - Moving manufactured home to location.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 5 2014-04-01 2014-04-01 false Moving manufactured home to... HOUSING AND URBAN DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Pre-Installation Considerations § 3285.104 Moving manufactured home to location. Refer to § 3285.902 for considerations related to...

  11. 24 CFR 3285.104 - Moving manufactured home to location.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 5 2012-04-01 2012-04-01 false Moving manufactured home to... HOUSING AND URBAN DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Pre-Installation Considerations § 3285.104 Moving manufactured home to location. Refer to § 3285.902 for considerations related to...

  12. 24 CFR 3285.104 - Moving manufactured home to location.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Moving manufactured home to... HOUSING AND URBAN DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Pre-Installation Considerations § 3285.104 Moving manufactured home to location. Refer to § 3285.902 for considerations related to...

  13. Registering Names and Addresses for Information Technology.

    ERIC Educational Resources Information Center

    Knapp, Arthur A.

    The identification of administrative authorities and the development of associated procedures for registering and accessing names and addresses of communications data systems are considered in this paper. It is noted that, for data communications systems using standards based on the Open Systems Interconnection (OSI) Reference Model specified by…

  14. 46 CFR 160.050-1 - Incorporation by reference.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Incorporation by reference. 160.050-1 Section 160.050-1....050-1 Incorporation by reference. (a) Standard. This subpart makes reference to Federal Standard No... Service Center, General Services Administration, Washington, DC 20407. [USCG-1999-6216, 64 FR 53228, Oct...

  15. Predicting oropharyngeal tumor volume throughout the course of radiation therapy from pretreatment computed tomography data using general linear models.

    PubMed

    Yock, Adam D; Rao, Arvind; Dong, Lei; Beadle, Beth M; Garden, Adam S; Kudchadker, Rajat J; Court, Laurence E

    2014-05-01

    The purpose of this work was to develop and evaluate the accuracy of several predictive models of variation in tumor volume throughout the course of radiation therapy. Nineteen patients with oropharyngeal cancers were imaged daily with CT-on-rails for image-guided alignment per an institutional protocol. The daily volumes of 35 tumors in these 19 patients were determined and used to generate (1) a linear model in which tumor volume changed at a constant rate, (2) a general linear model that utilized the power fit relationship between the daily and initial tumor volumes, and (3) a functional general linear model that identified and exploited the primary modes of variation between time series describing the changing tumor volumes. Primary and nodal tumor volumes were examined separately. The accuracy of these models in predicting daily tumor volumes were compared with those of static and linear reference models using leave-one-out cross-validation. In predicting the daily volume of primary tumors, the general linear model and the functional general linear model were more accurate than the static reference model by 9.9% (range: -11.6%-23.8%) and 14.6% (range: -7.3%-27.5%), respectively, and were more accurate than the linear reference model by 14.2% (range: -6.8%-40.3%) and 13.1% (range: -1.5%-52.5%), respectively. In predicting the daily volume of nodal tumors, only the 14.4% (range: -11.1%-20.5%) improvement in accuracy of the functional general linear model compared to the static reference model was statistically significant. A general linear model and a functional general linear model trained on data from a small population of patients can predict the primary tumor volume throughout the course of radiation therapy with greater accuracy than standard reference models. These more accurate models may increase the prognostic value of information about the tumor garnered from pretreatment computed tomography images and facilitate improved treatment management.

  16. A Comparative Study of Average, Linked Mastoid, and REST References for ERP Components Acquired during fMRI

    PubMed Central

    Yang, Ping; Fan, Chenggui; Wang, Min; Li, Ling

    2017-01-01

    In simultaneous electroencephalogram (EEG) and functional magnetic resonance imaging (fMRI) studies, average reference (AR), and digitally linked mastoid (LM) are popular re-referencing techniques in event-related potential (ERP) analyses. However, they may introduce their own physiological signals and alter the EEG/ERP outcome. A reference electrode standardization technique (REST) that calculated a reference point at infinity was proposed to solve this problem. To confirm the advantage of REST in ERP analyses of synchronous EEG-fMRI studies, we compared the reference effect of AR, LM, and REST on task-related ERP results of a working memory task during an fMRI scan. As we hypothesized, we found that the adopted reference did not change the topography map of ERP components (N1 and P300 in the present study), but it did alter the task-related effect on ERP components. LM decreased or eliminated the visual working memory (VWM) load effect on P300, and the AR distorted the distribution of VWM location-related effect at left posterior electrodes as shown in the statistical parametric scalp mapping (SPSM) of N1. ERP cortical source estimates, which are independent of the EEG reference choice, were used as the golden standard to infer the relative utility of different references on the ERP task-related effect. By comparison, REST reference provided a more integrated and reasonable result. These results were further confirmed by the results of fMRI activations and a corresponding EEG-only study. Thus, we recommend the REST, especially with a realistic head model, as the optimal reference method for ERP data analysis in simultaneous EEG-fMRI studies. PMID:28529472

  17. A Comparative Study of Average, Linked Mastoid, and REST References for ERP Components Acquired during fMRI.

    PubMed

    Yang, Ping; Fan, Chenggui; Wang, Min; Li, Ling

    2017-01-01

    In simultaneous electroencephalogram (EEG) and functional magnetic resonance imaging (fMRI) studies, average reference (AR), and digitally linked mastoid (LM) are popular re-referencing techniques in event-related potential (ERP) analyses. However, they may introduce their own physiological signals and alter the EEG/ERP outcome. A reference electrode standardization technique (REST) that calculated a reference point at infinity was proposed to solve this problem. To confirm the advantage of REST in ERP analyses of synchronous EEG-fMRI studies, we compared the reference effect of AR, LM, and REST on task-related ERP results of a working memory task during an fMRI scan. As we hypothesized, we found that the adopted reference did not change the topography map of ERP components (N1 and P300 in the present study), but it did alter the task-related effect on ERP components. LM decreased or eliminated the visual working memory (VWM) load effect on P300, and the AR distorted the distribution of VWM location-related effect at left posterior electrodes as shown in the statistical parametric scalp mapping (SPSM) of N1. ERP cortical source estimates, which are independent of the EEG reference choice, were used as the golden standard to infer the relative utility of different references on the ERP task-related effect. By comparison, REST reference provided a more integrated and reasonable result. These results were further confirmed by the results of fMRI activations and a corresponding EEG-only study. Thus, we recommend the REST, especially with a realistic head model, as the optimal reference method for ERP data analysis in simultaneous EEG-fMRI studies.

  18. Analytical performance specifications for changes in assay bias (Δbias) for data with logarithmic distributions as assessed by effects on reference change values.

    PubMed

    Petersen, Per H; Lund, Flemming; Fraser, Callum G; Sölétormos, György

    2016-11-01

    Background The distributions of within-subject biological variation are usually described as coefficients of variation, as are analytical performance specifications for bias, imprecision and other characteristics. Estimation of specifications required for reference change values is traditionally done using relationship between the batch-related changes during routine performance, described as Δbias, and the coefficients of variation for analytical imprecision (CV A ): the original theory is based on standard deviations or coefficients of variation calculated as if distributions were Gaussian. Methods The distribution of between-subject biological variation can generally be described as log-Gaussian. Moreover, recent analyses of within-subject biological variation suggest that many measurands have log-Gaussian distributions. In consequence, we generated a model for the estimation of analytical performance specifications for reference change value, with combination of Δbias and CV A based on log-Gaussian distributions of CV I as natural logarithms. The model was tested using plasma prolactin and glucose as examples. Results Analytical performance specifications for reference change value generated using the new model based on log-Gaussian distributions were practically identical with the traditional model based on Gaussian distributions. Conclusion The traditional and simple to apply model used to generate analytical performance specifications for reference change value, based on the use of coefficients of variation and assuming Gaussian distributions for both CV I and CV A , is generally useful.

  19. Optical-Fiber Power Meter Comparison Between NIST and PTB.

    PubMed

    Vayshenker, I; Haars, H; Li, X; Lehman, J H; Livigni, D J

    2003-01-01

    We describe the results of a comparison of reference standards between the National Institute of Standards and Technology (NIST-USA) and Physikalisch-Technische Bundesanstalt (PTB-Germany) at nominal wavelengths of 1300 nm and 1550 nm using an optical-fiber cable. Both laboratories used thermal detectors as reference standards. A novel temperature-controlled, optical-trap detector was used as a transfer standard to compare two reference standards. Measurement results showed differences of less than 1.5 × 10(-3), which is within the combined uncertainty for both laboratories.

  20. Unified Bayesian Estimator of EEG Reference at Infinity: rREST (Regularized Reference Electrode Standardization Technique)

    PubMed Central

    Hu, Shiang; Yao, Dezhong; Valdes-Sosa, Pedro A.

    2018-01-01

    The choice of reference for the electroencephalogram (EEG) is a long-lasting unsolved issue resulting in inconsistent usages and endless debates. Currently, both the average reference (AR) and the reference electrode standardization technique (REST) are two primary, apparently irreconcilable contenders. We propose a theoretical framework to resolve this reference issue by formulating both (a) estimation of potentials at infinity, and (b) determination of the reference, as a unified Bayesian linear inverse problem, which can be solved by maximum a posterior estimation. We find that AR and REST are very particular cases of this unified framework: AR results from biophysically non-informative prior; while REST utilizes the prior based on the EEG generative model. To allow for simultaneous denoising and reference estimation, we develop the regularized versions of AR and REST, named rAR and rREST, respectively. Both depend on a regularization parameter that is the noise to signal variance ratio. Traditional and new estimators are evaluated with this framework, by both simulations and analysis of real resting EEGs. Toward this end, we leverage the MRI and EEG data from 89 subjects which participated in the Cuban Human Brain Mapping Project. Generated artificial EEGs—with a known ground truth, show that relative error in estimating the EEG potentials at infinity is lowest for rREST. It also reveals that realistic volume conductor models improve the performances of REST and rREST. Importantly, for practical applications, it is shown that an average lead field gives the results comparable to the individual lead field. Finally, it is shown that the selection of the regularization parameter with Generalized Cross-Validation (GCV) is close to the “oracle” choice based on the ground truth. When evaluated with the real 89 resting state EEGs, rREST consistently yields the lowest GCV. This study provides a novel perspective to the EEG reference problem by means of a unified inverse solution framework. It may allow additional principled theoretical formulations and numerical evaluation of performance. PMID:29780302

  1. Field Demonstration and Validation of a New Device for Measuring Water and Solute Fluxes at CFB Borden

    DTIC Science & Technology

    2006-11-01

    All Quality Control Reference Materials are acquired only from authorized vendors or sources commonly used by U.S. EPA Regional Laboratories...Institue of Standards and Testing (NITS) Standard Reference Materials (SRM) or to the U.S. EPA Reference Standards. Working Standards The commercial...contaminants from clothing or equipment by blowing, shaking or any other means that may disperse material into the air is prohibited. 7.1.3. All disposable

  2. [Error prevention through management of complications in urology: standard operating procedures from commercial aviation as a model].

    PubMed

    Kranz, J; Sommer, K-J; Steffens, J

    2014-05-01

    Patient safety and risk/complication management rank among the current megatrends in modern medicine, which has undoubtedly become more complex. In time-critical, error-prone and difficult situations, which often occur repeatedly in everyday clinical practice, guidelines are inappropriate for acting rapidly and intelligently. With the establishment and consistent use of standard operating procedures like in commercial aviation, a possible strategic approach is available. These medical aids to decision-making - quick reference cards - are short, optimized instructions that enable a standardized procedure in case of medical claims.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eppich, Gary R.; Williams, Ross W.; Gaffney, Amy M.

    Here, age dating of nuclear material can provide insight into source and suspected use in nuclear forensic investigations. We report here a method for the determination of the date of most recent chemical purification for uranium materials using the 235U- 231Pa chronometer. Protactinium is separated from uranium and neptunium matrices using anion exchange resin, followed by sorption of Pa to an SiO 2 medium. The concentration of 231Pa is measured by isotope dilution mass spectrometry using 233Pa spikes prepared from an aliquot of 237Np and calibrated in-house using the rock standard Table Mountain Latite and the uranium isotopic standard U100.more » Combined uncertainties of age dates using this method are 1.5 to 3.5 %, an improvement over alpha spectrometry measurement methods. Model ages of five uranium standard reference materials are presented; all standards have concordant 235U- 231Pa and 234U- 230Th model ages.« less

  4. NASA standard: Trend analysis techniques

    NASA Technical Reports Server (NTRS)

    1988-01-01

    This Standard presents descriptive and analytical techniques for NASA trend analysis applications. Trend analysis is applicable in all organizational elements of NASA connected with, or supporting, developmental/operational programs. Use of this Standard is not mandatory; however, it should be consulted for any data analysis activity requiring the identification or interpretation of trends. Trend Analysis is neither a precise term nor a circumscribed methodology, but rather connotes, generally, quantitative analysis of time-series data. For NASA activities, the appropriate and applicable techniques include descriptive and graphical statistics, and the fitting or modeling of data by linear, quadratic, and exponential models. Usually, but not always, the data is time-series in nature. Concepts such as autocorrelation and techniques such as Box-Jenkins time-series analysis would only rarely apply and are not included in this Standard. The document presents the basic ideas needed for qualitative and quantitative assessment of trends, together with relevant examples. A list of references provides additional sources of information.

  5. Reference Architecture Model Enabling Standards Interoperability.

    PubMed

    Blobel, Bernd

    2017-01-01

    Advanced health and social services paradigms are supported by a comprehensive set of domains managed by different scientific disciplines. Interoperability has to evolve beyond information and communication technology (ICT) concerns, including the real world business domains and their processes, but also the individual context of all actors involved. So, the system must properly reflect the environment in front and around the computer as essential and even defining part of the health system. This paper introduces an ICT-independent system-theoretical, ontology-driven reference architecture model allowing the representation and harmonization of all domains involved including the transformation into an appropriate ICT design and implementation. The entire process is completely formalized and can therefore be fully automated.

  6. TU-G-204-03: Dynamic CT Myocardial Perfusion Measurement Using First Pass Analysis and Maximum Slope Models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hubbard, L; Ziemer, B; Sadeghi, B

    Purpose: To evaluate the accuracy of dynamic CT myocardial perfusion measurement using first pass analysis (FPA) and maximum slope models. Methods: A swine animal model was prepared by percutaneous advancement of an angioplasty balloon into the proximal left anterior descending (LAD) coronary artery to induce varying degrees of stenosis. Maximal hyperaemia was achieved in the LAD with an intracoronary adenosine drip (240 µg/min). Serial microsphere and contrast (370 mg/mL iodine, 30 mL, 5mL/s) injections were made over a range of induced stenoses, and dynamic imaging was performed using a 320-row CT scanner at 100 kVp and 200 mA. The FPAmore » CT perfusion technique was used to make vessel-specific myocardial perfusion measurements. CT perfusion measurements using the FPA and maximum slope models were validated using colored microspheres as the reference gold standard. Results: Perfusion measurements using the FPA technique (P-FPA) showed good correlation with minimal offset when compared to perfusion measurements using microspheres (P- Micro) as the reference standard (P -FPA = 0.96 P-Micro + 0.05, R{sup 2} = 0.97, RMSE = 0.19 mL/min/g). In contrast, the maximum slope model technique (P-MS) was shown to underestimate perfusion when compared to microsphere perfusion measurements (P-MS = 0.42 P -Micro −0.48, R{sup 2} = 0.94, RMSE = 3.3 mL/min/g). Conclusion: The results indicate the potential for significant improvements in accuracy of dynamic CT myocardial perfusion measurement using the first pass analysis technique as compared with the standard maximum slope model.« less

  7. Identifying appropriate reference data models for comparative effectiveness research (CER) studies based on data from clinical information systems.

    PubMed

    Ogunyemi, Omolola I; Meeker, Daniella; Kim, Hyeon-Eui; Ashish, Naveen; Farzaneh, Seena; Boxwala, Aziz

    2013-08-01

    The need for a common format for electronic exchange of clinical data prompted federal endorsement of applicable standards. However, despite obvious similarities, a consensus standard has not yet been selected in the comparative effectiveness research (CER) community. Using qualitative metrics for data retrieval and information loss across a variety of CER topic areas, we compare several existing models from a representative sample of organizations associated with clinical research: the Observational Medical Outcomes Partnership (OMOP), Biomedical Research Integrated Domain Group, the Clinical Data Interchange Standards Consortium, and the US Food and Drug Administration. While the models examined captured a majority of the data elements that are useful for CER studies, data elements related to insurance benefit design and plans were most detailed in OMOP's CDM version 4.0. Standardized vocabularies that facilitate semantic interoperability were included in the OMOP and US Food and Drug Administration Mini-Sentinel data models, but are left to the discretion of the end-user in Biomedical Research Integrated Domain Group and Analysis Data Model, limiting reuse opportunities. Among the challenges we encountered was the need to model data specific to a local setting. This was handled by extending the standard data models. We found that the Common Data Model from the OMOP met the broadest complement of CER objectives. Minimal information loss occurred in mapping data from institution-specific data warehouses onto the data models from the standards we assessed. However, to support certain scenarios, we found a need to enhance existing data dictionaries with local, institution-specific information.

  8. The role of standards in the development and implementation of clinical laboratory tests: a domestic and global perspective.

    PubMed

    Michaud, Ginette Y

    2005-01-01

    In the field of clinical laboratory medicine, standardization is aimed at increasing the trueness and reliability of measured values. Standardization relies on the use of written standards, reference measurement procedures and reference materials. These are important tools for the design and validation of new tests, and for establishing the metrological traceability of diagnostic assays. Their use supports the translation of research technologies into new diagnostic assays and leads to more rapid advances in science and medicine, as well as improvements in the quality of patient care. The various standardization tools are described, as are the procedures by which written standards, reference procedures and reference materials are developed. Recent efforts to develop standards for use in the field of molecular diagnostics are discussed. The recognition of standardization tools by the FDA and other regulatory authorities is noted as evidence of their important role in ensuring the safety and performance of in vitro diagnostic devices.

  9. Using features of Arden Syntax with object-oriented medical data models for guideline modeling.

    PubMed

    Peleg, M; Ogunyemi, O; Tu, S; Boxwala, A A; Zeng, Q; Greenes, R A; Shortliffe, E H

    2001-01-01

    Computer-interpretable guidelines (CIGs) can deliver patient-specific decision support at the point of care. CIGs base their recommendations on eligibility and decision criteria that relate medical concepts to patient data. CIG models use expression languages for specifying these criteria, and define models for medical data to which the expressions can refer. In developing version 3 of the GuideLine Interchange Format (GLIF3), we used existing standards as the medical data model and expression language. We investigated the object-oriented HL7 Reference Information Model (RIM) as a default data model. We developed an expression language, called GEL, based on Arden Syntax's logic grammar. Together with other GLIF constructs, GEL reconciles incompatibilities between the data models of Arden Syntax and the HL7 RIM. These incompatibilities include Arden's lack of support for complex data types and time intervals, and the mismatch between Arden's single primary time and multiple time attributes of the HL7 RIM.

  10. Reference tissue modeling with parameter coupling: application to a study of SERT binding in HIV

    NASA Astrophysics Data System (ADS)

    Endres, Christopher J.; Hammoud, Dima A.; Pomper, Martin G.

    2011-04-01

    When applicable, it is generally preferred to evaluate positron emission tomography (PET) studies using a reference tissue-based approach as that avoids the need for invasive arterial blood sampling. However, most reference tissue methods have been shown to have a bias that is dependent on the level of tracer binding, and the variability of parameter estimates may be substantially affected by noise level. In a study of serotonin transporter (SERT) binding in HIV dementia, it was determined that applying parameter coupling to the simplified reference tissue model (SRTM) reduced the variability of parameter estimates and yielded the strongest between-group significant differences in SERT binding. The use of parameter coupling makes the application of SRTM more consistent with conventional blood input models and reduces the total number of fitted parameters, thus should yield more robust parameter estimates. Here, we provide a detailed evaluation of the application of parameter constraint and parameter coupling to [11C]DASB PET studies. Five quantitative methods, including three methods that constrain the reference tissue clearance (kr2) to a common value across regions were applied to the clinical and simulated data to compare measurement of the tracer binding potential (BPND). Compared with standard SRTM, either coupling of kr2 across regions or constraining kr2 to a first-pass estimate improved the sensitivity of SRTM to measuring a significant difference in BPND between patients and controls. Parameter coupling was particularly effective in reducing the variance of parameter estimates, which was less than 50% of the variance obtained with standard SRTM. A linear approach was also improved when constraining kr2 to a first-pass estimate, although the SRTM-based methods yielded stronger significant differences when applied to the clinical study. This work shows that parameter coupling reduces the variance of parameter estimates and may better discriminate between-group differences in specific binding.

  11. Automated Spatial Brain Normalization and Hindbrain White Matter Reference Tissue Give Improved [(18)F]-Florbetaben PET Quantitation in Alzheimer's Model Mice.

    PubMed

    Overhoff, Felix; Brendel, Matthias; Jaworska, Anna; Korzhova, Viktoria; Delker, Andreas; Probst, Federico; Focke, Carola; Gildehaus, Franz-Josef; Carlsen, Janette; Baumann, Karlheinz; Haass, Christian; Bartenstein, Peter; Herms, Jochen; Rominger, Axel

    2016-01-01

    Preclinical PET studies of β-amyloid (Aβ) accumulation are of growing importance, but comparisons between research sites require standardized and optimized methods for quantitation. Therefore, we aimed to evaluate systematically the (1) impact of an automated algorithm for spatial brain normalization, and (2) intensity scaling methods of different reference regions for Aβ-PET in a large dataset of transgenic mice. PS2APP mice in a 6 week longitudinal setting (N = 37) and another set of PS2APP mice at a histologically assessed narrow range of Aβ burden (N = 40) were investigated by [(18)F]-florbetaben PET. Manual spatial normalization by three readers at different training levels was performed prior to application of an automated brain spatial normalization and inter-reader agreement was assessed by Fleiss Kappa (κ). For this method the impact of templates at different pathology stages was investigated. Four different reference regions on brain uptake normalization were used to calculate frontal cortical standardized uptake value ratios (SUVRCTX∕REF), relative to raw SUVCTX. Results were compared on the basis of longitudinal stability (Cohen's d), and in reference to gold standard histopathological quantitation (Pearson's R). Application of an automated brain spatial normalization resulted in nearly perfect agreement (all κ≥0.99) between different readers, with constant or improved correlation with histology. Templates based on inappropriate pathology stage resulted in up to 2.9% systematic bias for SUVRCTX∕REF. All SUVRCTX∕REF methods performed better than SUVCTX both with regard to longitudinal stability (d≥1.21 vs. d = 0.23) and histological gold standard agreement (R≥0.66 vs. R≥0.31). Voxel-wise analysis suggested a physiologically implausible longitudinal decrease by global mean scaling. The hindbrain white matter reference (R mean = 0.75) was slightly superior to the brainstem (R mean = 0.74) and the cerebellum (R mean = 0.73). Automated brain normalization with reference region templates presents an excellent method to avoid the inter-reader variability in preclinical Aβ-PET scans. Intracerebral reference regions lacking Aβ pathology serve for precise longitudinal in vivo quantification of [(18)F]-florbetaben PET. Hindbrain white matter reference performed best when considering the composite of quality criteria.

  12. Detailed clinical models: a review.

    PubMed

    Goossen, William; Goossen-Baremans, Anneke; van der Zel, Michael

    2010-12-01

    Due to the increasing use of electronic patient records and other health care information technology, we see an increase in requests to utilize these data. A highly level of standardization is required during the gathering of these data in the clinical context in order to use it for analyses. Detailed Clinical Models (DCM) have been created toward this purpose and several initiatives have been implemented in various parts of the world to create standardized models. This paper presents a review of DCM. Two types of analyses are presented; one comparing DCM against health care information architectures and a second bottom up approach from concept analysis to representation. In addition core parts of the draft ISO standard 13972 on DCM are used such as clinician involvement, data element specification, modeling, meta information, and repository and governance. SIX INITIATIVES WERE SELECTED: Intermountain Healthcare, 13606/OpenEHR Archetypes, Clinical Templates, Clinical Contents Models, Health Level 7 templates, and Dutch Detailed Clinical Models. Each model selected was reviewed for their overall development, involvement of clinicians, use of data types, code bindings, expressing semantics, modeling, meta information, use of repository and governance. Using both a top down and bottom up approach to comparison reveals many commonalties and differences between initiatives. Important differences include the use of or lack of a reference model and expressiveness of models. Applying clinical data element standards facilitates the use of conceptual DCM models in different technical representations.

  13. 78 FR 7718 - Review of the General Purpose Costing System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-04

    ... for switching cars, regardless of car ownership. These costs are referred to as ``switch engine minute... provide the railroad industry and shippers with a standardized costing model; to cost the Board's Car Load... movement. Next, URCS applies ``efficiency adjustments'' to higher-volume movements (multi-car and trainload...

  14. Genomic Model with Correlation Between Additive and Dominance Effects.

    PubMed

    Xiang, Tao; Christensen, Ole Fredslund; Vitezica, Zulma Gladis; Legarra, Andres

    2018-05-09

    Dominance genetic effects are rarely included in pedigree-based genetic evaluation. With the availability of single nucleotide polymorphism markers and the development of genomic evaluation, estimates of dominance genetic effects have become feasible using genomic best linear unbiased prediction (GBLUP). Usually, studies involving additive and dominance genetic effects ignore possible relationships between them. It has been often suggested that the magnitude of functional additive and dominance effects at the quantitative trait loci are related, but there is no existing GBLUP-like approach accounting for such correlation. Wellmann and Bennewitz showed two ways of considering directional relationships between additive and dominance effects, which they estimated in a Bayesian framework. However, these relationships cannot be fitted at the level of individuals instead of loci in a mixed model and are not compatible with standard animal or plant breeding software. This comes from a fundamental ambiguity in assigning the reference allele at a given locus. We show that, if there has been selection, assigning the most frequent as the reference allele orients the correlation between functional additive and dominance effects. As a consequence, the most frequent reference allele is expected to have a positive value. We also demonstrate that selection creates negative covariance between genotypic additive and dominance genetic values. For parameter estimation, it is possible to use a combined additive and dominance relationship matrix computed from marker genotypes, and to use standard restricted maximum likelihood (REML) algorithms based on an equivalent model. Through a simulation study, we show that such correlations can easily be estimated by mixed model software and accuracy of prediction for genetic values is slightly improved if such correlations are used in GBLUP. However, a model assuming uncorrelated effects and fitting orthogonal breeding values and dominant deviations performed similarly for prediction. Copyright © 2018, Genetics.

  15. Short communication: Development of an equation for estimating methane emissions of dairy cows from milk Fourier transform mid-infrared spectra by using reference data obtained exclusively from respiration chambers.

    PubMed

    Vanlierde, A; Soyeurt, H; Gengler, N; Colinet, F G; Froidmont, E; Kreuzer, M; Grandl, F; Bell, M; Lund, P; Olijhoek, D W; Eugène, M; Martin, C; Kuhla, B; Dehareng, F

    2018-05-09

    Evaluation and mitigation of enteric methane (CH 4 ) emissions from ruminant livestock, in particular from dairy cows, have acquired global importance for sustainable, climate-smart cattle production. Based on CH 4 reference measurements obtained with the SF 6 tracer technique to determine ruminal CH 4 production, a current equation permits evaluation of individual daily CH 4 emissions of dairy cows based on milk Fourier transform mid-infrared (FT-MIR) spectra. However, the respiration chamber (RC) technique is considered to be more accurate than SF 6 to measure CH 4 production from cattle. This study aimed to develop an equation that allows estimating CH 4 emissions of lactating cows recorded in an RC from corresponding milk FT-MIR spectra and to challenge its robustness and relevance through validation processes and its application on a milk spectral database. This would permit confirming the conclusions drawn with the existing equation based on SF 6 reference measurements regarding the potential to estimate daily CH 4 emissions of dairy cows from milk FT-MIR spectra. A total of 584 RC reference CH 4 measurements (mean ± standard deviation of 400 ± 72 g of CH 4 /d) and corresponding standardized milk mid-infrared spectra were obtained from 148 individual lactating cows between 7 and 321 d in milk in 5 European countries (Germany, Switzerland, Denmark, France, and Northern Ireland). The developed equation based on RC measurements showed calibration and cross-validation coefficients of determination of 0.65 and 0.57, respectively, which is lower than those obtained earlier by the equation based on 532 SF 6 measurements (0.74 and 0.70, respectively). This means that the RC-based model is unable to explain the variability observed in the corresponding reference data as well as the SF 6 -based model. The standard errors of calibration and cross-validation were lower for the RC model (43 and 47 g/d vs. 66 and 70 g/d for the SF 6 version, respectively), indicating that the model based on RC data was closer to actual values. The root mean squared error (RMSE) of calibration of 42 g/d represents only 10% of the overall daily CH 4 production, which is 23 g/d lower than the RMSE for the SF 6 -based equation. During the external validation step an RMSE of 62 g/d was observed. When the RC equation was applied to a standardized spectral database of milk recordings collected in the Walloon region of Belgium between January 2012 and December 2017 (1,515,137 spectra from 132,658 lactating cows in 1,176 different herds), an average ± standard deviation of 446 ± 51 g of CH 4 /d was estimated, which is consistent with the range of the values measured using both RC and SF 6 techniques. This study confirmed that milk FT-MIR spectra could be used as a potential proxy to estimate daily CH 4 emissions from dairy cows provided that the variability to predict is covered by the model. The Authors. Published by FASS Inc. and Elsevier Inc. on behalf of the American Dairy Science Association®. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/3.0/).

  16. Research on the management and endorsement of nuclear safety standards in the United States and its revelation for China

    NASA Astrophysics Data System (ADS)

    Liu, Ting; Tian, Yu; Yang, Lili; Gao, Siyi; Song, Dahu

    2018-01-01

    This paper introduces the American standard system, the Nuclear Regulatory Commission (NRC)’s responsibility, NRC nuclear safety regulations and standards system, studies on NRC’s standards management and endorsement mode, analyzes the characteristics of NRC standards endorsement management, and points out its disadvantages. This paper draws revelation from the standard management and endorsement model of NRC and points suggestion to China’s nuclear and radiation safety standards management.The issue of the “Nuclear Safety Law”plays an important role in China’s nuclear and radiation safety supervision. Nuclear and radiation safety regulations and standards are strong grips on the implementation of “Nuclear Safety Law”. This paper refers on the experience of international advanced countriy, will effectively promote the improvement of the endorsed management of China’s nuclear and radiation safety standards.

  17. POTENTIAL RADIOACTIVE POLLUTANTS RESULTING FROM EXPANDED ENERGY PROGRAMS

    EPA Science Inventory

    An effective environmental monitoring program must have a quality assurance component to assure the production of valid data. Quality assurance has many components: calibration standards, standard reference materials, standard reference methods, interlaboratory comparison studies...

  18. Effects of non-tidal atmospheric loading on a Kalman filter-based terrestrial reference frame

    NASA Astrophysics Data System (ADS)

    Abbondanza, C.; Altamimi, Z.; Chin, T. M.; Collilieux, X.; Dach, R.; Heflin, M. B.; Gross, R. S.; König, R.; Lemoine, F. G.; MacMillan, D. S.; Parker, J. W.; van Dam, T. M.; Wu, X.

    2013-12-01

    The International Terrestrial Reference Frame (ITRF) adopts a piece-wise linear model to parameterize regularized station positions and velocities. The space-geodetic (SG) solutions from VLBI, SLR, GPS and DORIS global networks used as input in the ITRF combination process account for tidal loading deformations, but ignore the non-tidal part. As a result, the non-linear signal observed in the time series of SG-derived station positions in part reflects non-tidal loading displacements not introduced in the SG data reduction. In this analysis, the effect of non-tidal atmospheric loading (NTAL) corrections on the TRF is assessed adopting a Remove/Restore approach: (i) Focusing on the a-posteriori approach, the NTAL model derived from the National Center for Environmental Prediction (NCEP) surface pressure is removed from the SINEX files of the SG solutions used as inputs to the TRF determinations. (ii) Adopting a Kalman-filter based approach, a linear TRF is estimated combining the 4 SG solutions free from NTAL displacements. (iii) Linear fits to the NTAL displacements removed at step (i) are restored to the linear reference frame estimated at (ii). The velocity fields of the (standard) linear reference frame in which the NTAL model has not been removed and the one in which the model has been removed/restored are compared and discussed.

  19. [Preparation of flavonoid reference standards from Scutellariae Radix under the guidance of high performance liquid chromatography-mass spectrometry analysis].

    PubMed

    Guo, Henan; Yang, Xuedong; Liu, Jun; Zheng, Wenfeng

    2012-07-01

    Flavonoid reference standards were targeted-prepared from Scutellariae Radix under the guidance of high performance liquid chromatography-mass spectrometry (HPLC-MS) analysis. With HPLC-MS analysis of Scutellariae Radix, 19 flavonoid components were identified by analyzing and comparing their retention times, ultraviolet spectra, and mass spectrometry data with literature. The separation and purification protocols of all targeted flavonoid reference standards were optimally designed according to the results of HPLC-MS analysis and related literature. The ethanol extract of Scutellariae Radix was suspended in water and extracted with petroleum ether, ethyl acetate, and n-butanol successively. The ethyl acetate extract and n-butanol extract were separately subjected to primary separation by low pressure reverse phase preparative chromatography. Then the fractions containing targeted compounds were further purified by low pressure reverse and normal phases preparative chromatography. Finally, baicalin and wogonoside reference standards were obtained from n-butanol extract; baicaelin, wogonin, and oroxylin A reference standards were obtained from ethyl acetate extract. The structures of the 5 reference standards were identified by mass spectrometry (MS) and 1H nuclear magnetic resonance (1H NMR) spectroscopy. The HPLC analytical results showed that the purities of the 5 reference standards were all above 98%. It is demonstrated that the rapid targeted-preparation method under the guidance of the HPLC-MS analysis is applicable for the isolation and preparation of chemical components in traditional Chinese medicines.

  20. The Current Status and Tendency of China Millimeter Coordinate Frame Implementation and Maintenance

    NASA Astrophysics Data System (ADS)

    Cheng, P.; Cheng, Y.; Bei, J.

    2017-12-01

    China Geodetic Coordinate System 2000 (CGCS2000) was first officially declared as the national standard coordinate system on July 1, 2008. This reference frame was defined in the ITRF97 frame at epoch 2000.0 and included 2600 GPS geodetic control points. The paper discusses differences between China Geodetic Coordinate System 2000 (CGCS2000) and later updated ITRF versions, such as ITRF2014,in terms of technical implementation and maintenance. With the development of the Beidou navigation satellite system, especially third generation of BDS with signal global coverage in the future, and with progress of space geodetic technology, it is possible for us to establish a global millimeter-level reference frame based on space geodetic technology including BDS. The millimeter reference frame implementation concerns two factors: 1) The variation of geocenter motion estimation, and 2) the site nonlinear motion modeling. In this paper, the geocentric inversion methods are discussed and compared among results derived from various technical methods. Our nonlinear site movement modeling focuses on singular spectrum analysis method, which is of apparent advantages over earth physical effect modeling. All presented in the paper expected to provide reference to our future CGCS2000 maintenance.

  1. 18 CFR 3c.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... employee ethical conduct standards and financial disclosure regulations. 3c.1 Section 3c.1 Conservation of... STANDARDS OF CONDUCT § 3c.1 Cross-reference to employee ethical conduct standards and financial disclosure... branch-wide financial disclosure regulations at 5 CFR part 2634, the Standards of Ethical Conduct for...

  2. 13 CFR 105.101 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... ethical conduct standards and financial disclosure regulations. 105.101 Section 105.101 Business Credit... RESPONSIBILITIES Standards of Conduct § 105.101 Cross-reference to employee ethical conduct standards and financial... to the Standards of Ethical Conduct for Employees of the Executive Branch at 5 CFR part 2635 and the...

  3. 13 CFR 105.101 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... ethical conduct standards and financial disclosure regulations. 105.101 Section 105.101 Business Credit... RESPONSIBILITIES Standards of Conduct § 105.101 Cross-reference to employee ethical conduct standards and financial... to the Standards of Ethical Conduct for Employees of the Executive Branch at 5 CFR part 2635 and the...

  4. 18 CFR 3c.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... employee ethical conduct standards and financial disclosure regulations. 3c.1 Section 3c.1 Conservation of... STANDARDS OF CONDUCT § 3c.1 Cross-reference to employee ethical conduct standards and financial disclosure... branch-wide financial disclosure regulations at 5 CFR part 2634, the Standards of Ethical Conduct for...

  5. 18 CFR 3c.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... employee ethical conduct standards and financial disclosure regulations. 3c.1 Section 3c.1 Conservation of... STANDARDS OF CONDUCT § 3c.1 Cross-reference to employee ethical conduct standards and financial disclosure... branch-wide financial disclosure regulations at 5 CFR part 2634, the Standards of Ethical Conduct for...

  6. 18 CFR 3c.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... employee ethical conduct standards and financial disclosure regulations. 3c.1 Section 3c.1 Conservation of... STANDARDS OF CONDUCT § 3c.1 Cross-reference to employee ethical conduct standards and financial disclosure... branch-wide financial disclosure regulations at 5 CFR part 2634, the Standards of Ethical Conduct for...

  7. 18 CFR 3c.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... employee ethical conduct standards and financial disclosure regulations. 3c.1 Section 3c.1 Conservation of... STANDARDS OF CONDUCT § 3c.1 Cross-reference to employee ethical conduct standards and financial disclosure... branch-wide financial disclosure regulations at 5 CFR part 2634, the Standards of Ethical Conduct for...

  8. 13 CFR 105.101 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... ethical conduct standards and financial disclosure regulations. 105.101 Section 105.101 Business Credit... RESPONSIBILITIES Standards of Conduct § 105.101 Cross-reference to employee ethical conduct standards and financial... to the Standards of Ethical Conduct for Employees of the Executive Branch at 5 CFR part 2635 and the...

  9. 13 CFR 105.101 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... ethical conduct standards and financial disclosure regulations. 105.101 Section 105.101 Business Credit... RESPONSIBILITIES Standards of Conduct § 105.101 Cross-reference to employee ethical conduct standards and financial... to the Standards of Ethical Conduct for Employees of the Executive Branch at 5 CFR part 2635 and the...

  10. 13 CFR 105.101 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... ethical conduct standards and financial disclosure regulations. 105.101 Section 105.101 Business Credit... RESPONSIBILITIES Standards of Conduct § 105.101 Cross-reference to employee ethical conduct standards and financial... to the Standards of Ethical Conduct for Employees of the Executive Branch at 5 CFR part 2635 and the...

  11. [Use of theories and models on papers of a Latin-American journal in public health, 2000 to 2004].

    PubMed

    Cabrera Arana, Gustavo Alonso

    2007-12-01

    To characterize frequency and type of use of theories or models on papers of a Latin-American journal in public health between 2000 and 2004. The Revista de Saúde Pública was chosen because of its history of periodic publication without interruption and current impact on the scientific communication of the area. A standard procedure was applied for reading and classifying articles in an arbitrary typology of four levels, according to the depth of the use of models or theoretical references to describe problems or issues, to formulate methods and to discuss results. Of 482 articles included, 421 (87%) were research studies, 42 (9%) reviews or special contributions and 19 (4%) opinion texts or assays . Of 421 research studies, 286 (68%) had a quantitative focus, 110 (26%) qualitative and 25 (6%) mixed. Reference to theories or models is uncommon, only 90 (19%) articles mentioned a theory or model. According to the depth of the use, 29 (6%) were classified as type I, 9 (2%) as type II, 6 (1.3%) were type III and the 46 remaining texts (9.5%) were type IV. Reference to models was nine-fold more frequent than the use of theoretical references. The ideal use, type IV, occurred in one of every ten articles studied. It is of relevance to show theoretical and models frames used when approaching topics, formulating hypothesis, designing methods and discussing findings in papers.

  12. Studies on Wound Healing Activity of Heliotropium indicum Linn. Leaves on Rats.

    PubMed

    Dash, G K; Murthy, P N

    2011-01-01

    The petroleum ether, chloroform, methanol, and aqueous extracts of Heliotropium indicum Linn. (Family: Boraginaceae) were separately evaluated for their wound healing activity in rats using excision (normal and infected), incision, and dead space wound models. The effects of test samples on the rate of wound healing were assessed by the rate of wound closure, period of epithelialisation, wound breaking strength, weights of the granulation tissue, determination of hydroxyproline, super oxide dismutase (SOD), catalase, and histopathology of the granulation tissues. Nitrofurazone (0.2% w/w) in simple ointment I. P. was used as reference standard for the activity comparison. The results revealed significant promotion of wound healing with both methanol and aqueous extracts with more promising activity with the methanol extract compared to other extracts under study. In the wound infection model (with S. aureus and P. aeruginosa), the methanol extract showed significant healing activity similar to the reference standard nitrofurazone. Significant increase in the granulation tissue weight, increased hydroxyproline content, and increased activity of SOD and catalase level with the animals treated with methanol extract in dead space wound model further augmented the wound healing potential of H. indicum. The present work substantiates its validity of the folklore use.

  13. Studies on Wound Healing Activity of Heliotropium indicum Linn. Leaves on Rats

    PubMed Central

    Dash, G. K.; Murthy, P. N.

    2011-01-01

    The petroleum ether, chloroform, methanol, and aqueous extracts of Heliotropium indicum Linn. (Family: Boraginaceae) were separately evaluated for their wound healing activity in rats using excision (normal and infected), incision, and dead space wound models. The effects of test samples on the rate of wound healing were assessed by the rate of wound closure, period of epithelialisation, wound breaking strength, weights of the granulation tissue, determination of hydroxyproline, super oxide dismutase (SOD), catalase, and histopathology of the granulation tissues. Nitrofurazone (0.2% w/w) in simple ointment I. P. was used as reference standard for the activity comparison. The results revealed significant promotion of wound healing with both methanol and aqueous extracts with more promising activity with the methanol extract compared to other extracts under study. In the wound infection model (with S. aureus and P. aeruginosa), the methanol extract showed significant healing activity similar to the reference standard nitrofurazone. Significant increase in the granulation tissue weight, increased hydroxyproline content, and increased activity of SOD and catalase level with the animals treated with methanol extract in dead space wound model further augmented the wound healing potential of H. indicum. The present work substantiates its validity of the folklore use. PMID:22084720

  14. Coordinated EV adoption: double-digit reductions in emissions and fuel use for $40/vehicle-year.

    PubMed

    Choi, Dong Gu; Kreikebaum, Frank; Thomas, Valerie M; Divan, Deepak

    2013-09-17

    Adoption of electric vehicles (EVs) would affect the costs and sources of electricity and the United States efficiency requirements for conventional vehicles (CVs). We model EV adoption scenarios in each of six regions of the Eastern Interconnection, containing 70% of the United States population. We develop electricity system optimization models at the multidecade, day-ahead, and hour-ahead time scales, incorporating spatial wind energy modeling, endogenous modeling of CV efficiencies, projections for EV efficiencies, and projected CV and EV costs. We find two means to reduce total consumer expenditure (TCE): (i) controlling charge timing and (ii) unlinking the fuel economy regulations for CVs from EVs. Although EVs provide minimal direct GHG reductions, controlled charging provides load flexibility, lowering the cost of renewable electricity. Without EVs, a 33% renewable electricity standard (RES) would cost $193/vehicle-year more than the reference case (10% RES). Combining a 33% RES, EVs with controlled charging and unlinking would reduce combined electric- and vehicle-sector CO2 emissions by 27% and reduce gasoline consumption by 59% for $40/vehicle-year more than the reference case. Coordinating EV adoption with adoption of controlled charging, unlinked fuel economy regulations, and renewable electricity standards would provide low-cost reductions in emissions and fuel usage.

  15. A Proposal of New Reference System for the Standard Axial, Sagittal, Coronal Planes of Brain Based on the Serially-Sectioned Images

    PubMed Central

    Park, Jin Seo; Park, Hyo Seok; Shin, Dong Sun; Har, Dong-Hwan; Cho, Zang-Hee; Kim, Young-Bo; Han, Jae-Yong; Chi, Je-Geun

    2010-01-01

    Sectional anatomy of human brain is useful to examine the diseased brain as well as normal brain. However, intracerebral reference points for the axial, sagittal, and coronal planes of brain have not been standardized in anatomical sections or radiological images. We made 2,343 serially-sectioned images of a cadaver head with 0.1 mm intervals, 0.1 mm pixel size, and 48 bit color and obtained axial, sagittal, and coronal images based on the proposed reference system. This reference system consists of one principal reference point and two ancillary reference points. The two ancillary reference points are the anterior commissure and the posterior commissure. And the principal reference point is the midpoint of two ancillary reference points. It resides in the center of whole brain. From the principal reference point, Cartesian coordinate of x, y, z could be made to be the standard axial, sagittal, and coronal planes. PMID:20052359

  16. 12 CFR 400.101 - Cross-reference to employee financial disclosure and ethical conduct standards regulations.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... disclosure and ethical conduct standards regulations. 400.101 Section 400.101 Banks and Banking EXPORT-IMPORT BANK OF THE UNITED STATES EMPLOYEE FINANCIAL DISCLOSURE AND ETHICAL CONDUCT STANDARDS REGULATIONS § 400.101 Cross-reference to employee financial disclosure and ethical conduct standards regulations...

  17. 36 CFR 811.1 - Cross-references to employees' ethical conduct standards, financial disclosure and financial...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...' ethical conduct standards, financial disclosure and financial interests regulations and other conduct... EMPLOYEE RESPONSIBILITIES AND CONDUCT § 811.1 Cross-references to employees' ethical conduct standards... Council on Historic Preservation are subject to the executive branch-wide standards of ethical conduct...

  18. 36 CFR 811.1 - Cross-references to employees' ethical conduct standards, financial disclosure and financial...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...' ethical conduct standards, financial disclosure and financial interests regulations and other conduct... EMPLOYEE RESPONSIBILITIES AND CONDUCT § 811.1 Cross-references to employees' ethical conduct standards... Council on Historic Preservation are subject to the executive branch-wide standards of ethical conduct...

  19. 12 CFR 400.101 - Cross-reference to employee financial disclosure and ethical conduct standards regulations.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... disclosure and ethical conduct standards regulations. 400.101 Section 400.101 Banks and Banking EXPORT-IMPORT BANK OF THE UNITED STATES EMPLOYEE FINANCIAL DISCLOSURE AND ETHICAL CONDUCT STANDARDS REGULATIONS § 400.101 Cross-reference to employee financial disclosure and ethical conduct standards regulations...

  20. 12 CFR 400.101 - Cross-reference to employee financial disclosure and ethical conduct standards regulations.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... disclosure and ethical conduct standards regulations. 400.101 Section 400.101 Banks and Banking EXPORT-IMPORT BANK OF THE UNITED STATES EMPLOYEE FINANCIAL DISCLOSURE AND ETHICAL CONDUCT STANDARDS REGULATIONS § 400.101 Cross-reference to employee financial disclosure and ethical conduct standards regulations...

  1. 12 CFR 400.101 - Cross-reference to employee financial disclosure and ethical conduct standards regulations.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... disclosure and ethical conduct standards regulations. 400.101 Section 400.101 Banks and Banking EXPORT-IMPORT BANK OF THE UNITED STATES EMPLOYEE FINANCIAL DISCLOSURE AND ETHICAL CONDUCT STANDARDS REGULATIONS § 400.101 Cross-reference to employee financial disclosure and ethical conduct standards regulations...

  2. 36 CFR 811.1 - Cross-references to employees' ethical conduct standards, financial disclosure and financial...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...' ethical conduct standards, financial disclosure and financial interests regulations and other conduct... EMPLOYEE RESPONSIBILITIES AND CONDUCT § 811.1 Cross-references to employees' ethical conduct standards... Council on Historic Preservation are subject to the executive branch-wide standards of ethical conduct...

  3. 12 CFR 400.101 - Cross-reference to employee financial disclosure and ethical conduct standards regulations.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... disclosure and ethical conduct standards regulations. 400.101 Section 400.101 Banks and Banking EXPORT-IMPORT BANK OF THE UNITED STATES EMPLOYEE FINANCIAL DISCLOSURE AND ETHICAL CONDUCT STANDARDS REGULATIONS § 400.101 Cross-reference to employee financial disclosure and ethical conduct standards regulations...

  4. 36 CFR 811.1 - Cross-references to employees' ethical conduct standards, financial disclosure and financial...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...' ethical conduct standards, financial disclosure and financial interests regulations and other conduct... EMPLOYEE RESPONSIBILITIES AND CONDUCT § 811.1 Cross-references to employees' ethical conduct standards... Council on Historic Preservation are subject to the executive branch-wide standards of ethical conduct...

  5. Control vocabulary software designed for CMIP6

    NASA Astrophysics Data System (ADS)

    Nadeau, D.; Taylor, K. E.; Williams, D. N.; Ames, S.

    2016-12-01

    The Coupled Model Intercomparison Project Phase 6 (CMIP6) coordinates a number of intercomparison activities and includes many more experiments than its predecessor, CMIP5. In order to organize and facilitate use of the complex collection of expected CMIP6 model output, a standard set of descriptive information has been defined, which must be stored along with the data. This standard information enables automated machine interpretation of the contents of all model output files. The standard metadata is stored in compliance with the Climate and Forecast (CF) standard, which ensures that it can be interpreted and visualized by many standard software packages. Additional attributes (not standardized by CF) are required by CMIP6 to enhance identification of models and experiments, and to provide additional information critical for interpreting the model results. To ensure that CMIP6 data complies with the standards, a python program called "PrePARE" (Pre-Publication Attribute Reviewer for the ESGF) has been developed to check the model output prior to its publication and release for analysis. If, for example, a required attribute is missing or incorrect (e.g., not included in the reference CMIP6 controlled vocabularies), then PrePare will prevent publication. In some circumstances, missing attributes can be created or incorrect attributes can be replaced automatically by PrePARE, and the program will warn users about the changes that have been made. PrePARE provides a final check on model output assuring adherence to a baseline conformity across the output from all CMIP6 models which will facilitate analysis by climate scientists. PrePARE is flexible and can be easily modified for use by similar projects that have a well-defined set of metadata and controlled vocabularies.

  6. 22 CFR 1001.1 - Cross-references to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 22 Foreign Relations 2 2011-04-01 2009-04-01 true Cross-references to employee ethical conduct... FOUNDATION EMPLOYEE RESPONSIBILITIES AND CONDUCT § 1001.1 Cross-references to employee ethical conduct... Foundation should refer to the Standards of Ethical Conduct for Employees of the Executive Branch at 5 CFR...

  7. 15 CFR 230.7 - Description of services and list of fees, incorporation by reference.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... STANDARD REFERENCE MATERIALS STANDARD REFERENCE MATERIALS Description of Services and List of Fees § 230.7 Description of services and list of fees, incorporation by reference. (a) The text of NIST Special Publication... 15 Commerce and Foreign Trade 1 2010-01-01 2010-01-01 false Description of services and list of...

  8. 22 CFR 1001.1 - Cross-references to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 22 Foreign Relations 2 2010-04-01 2010-04-01 true Cross-references to employee ethical conduct... FOUNDATION EMPLOYEE RESPONSIBILITIES AND CONDUCT § 1001.1 Cross-references to employee ethical conduct... Foundation should refer to the Standards of Ethical Conduct for Employees of the Executive Branch at 5 CFR...

  9. 22 CFR 1001.1 - Cross-references to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 22 Foreign Relations 2 2014-04-01 2014-04-01 false Cross-references to employee ethical conduct... FOUNDATION EMPLOYEE RESPONSIBILITIES AND CONDUCT § 1001.1 Cross-references to employee ethical conduct... Foundation should refer to the Standards of Ethical Conduct for Employees of the Executive Branch at 5 CFR...

  10. 22 CFR 1001.1 - Cross-references to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 22 Foreign Relations 2 2013-04-01 2009-04-01 true Cross-references to employee ethical conduct... FOUNDATION EMPLOYEE RESPONSIBILITIES AND CONDUCT § 1001.1 Cross-references to employee ethical conduct... Foundation should refer to the Standards of Ethical Conduct for Employees of the Executive Branch at 5 CFR...

  11. 22 CFR 1001.1 - Cross-references to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 22 Foreign Relations 2 2012-04-01 2009-04-01 true Cross-references to employee ethical conduct... FOUNDATION EMPLOYEE RESPONSIBILITIES AND CONDUCT § 1001.1 Cross-references to employee ethical conduct... Foundation should refer to the Standards of Ethical Conduct for Employees of the Executive Branch at 5 CFR...

  12. Evaluation of the accuracy of extraoral laboratory scanners with a single-tooth abutment model: A 3D analysis.

    PubMed

    Mandelli, Federico; Gherlone, Enrico; Gastaldi, Giorgio; Ferrari, Marco

    2017-10-01

    The aim of this study was to compare the accuracy of different laboratory scanners using a calibrated coordinate measuring machine as reference. A sand blasted titanium reference model (RM) was scanned with an industrial 3D scanner in order to obtain a reference digital model (dRM) that was saved in the standard tessellation format (.stl). RM was scanned ten times with each one of the tested scanners (GC Europe Aadva, Zfx Evolution, 3Shape D640, 3Shape D700, NobilMetal Sinergia, EGS DScan3, Open Technologies Concept Scan Top) and all the scans were exported in .stl format for the comparison. All files were imported in a dedicated software (Geomagic Qualify 2013). Accuracy was evaluated calculating trueness and precision. Trueness values (μm [95% confidence interval]) were: Aadva 7,7 [6,8-8,5]; Zfx Evolution 9,2 [8,6-9,8]; D640 18,1 [12,2-24,0]; D700 12,8 [12,4-13,3]; Sinergia 31,1 [26,3-35,9]; DScan3 15,6 [11,5-19,7]; Concept Scan Top 28,6 [25,6-31,6]. Differences between scanners were statistically significant (p<.0005). Precision values (μm [95% CI]) were: Aadva 4,0 [3,8-4,2]; Zfx Evolution 5,1 [4,4-5,9]; D640 12,7 [12,4-13,1]; D700 11,0 [10,7-11,3]; Sinergia 16,3 [15,0-17,5]; DScan3 9,5 [8,3-10,6]; Concept Scan Top 19,5 [19,1-19,8]. Differences between scanners were statistically significant (p<.0005). The use a standardized scanning procedure fabricating a titanium reference model is useful to compare trueness and precision of different laboratory scanners; two laboratory scanners (Aadva, Zfx Evolution) were significantly better that other tested scanners. Copyright © 2016 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  13. A series of strategies for solving the shortage of reference standards for multi-components determination of traditional Chinese medicine, Mahoniae Caulis as a case.

    PubMed

    Wang, Wenguang; Ma, Xiaoli; Guo, Xiaoyu; Zhao, Mingbo; Tu, Pengfei; Jiang, Yong

    2015-09-18

    In order to solve the bottleneck of reference standards shortage for comprehensive quality control of traditional Chinese medicines (TCMs), a series of strategies, including one single reference standard to determine multi-compounds (SSDMC), quantitative analysis by standardized reference extract (QASRE), and quantitative nuclear magnetic resonance spectroscopy (qNMR) were proposed, and Mahoniae Caulis was selected as an example to develop and validate these methods for simultaneous determination of four alkaloids, columbamine, jatrorrhizine, palmatine, and berberine. Comprehensive comparisons among these methods and with the conventional external standard method (ESM) were carried out. The relative expanded uncertainty of measurement was firstly used to compare their credibility. The results showed that all these three new developed methods can accurately accomplish the quantification by using only one purified reference standard, but each of them has its own advantages and disadvantages as well as the specific application scope, which were also discussed in detail in this paper. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Use of Two-Part Regression Calibration Model to Correct for Measurement Error in Episodically Consumed Foods in a Single-Replicate Study Design: EPIC Case Study

    PubMed Central

    Agogo, George O.; van der Voet, Hilko; Veer, Pieter van’t; Ferrari, Pietro; Leenders, Max; Muller, David C.; Sánchez-Cantalejo, Emilio; Bamia, Christina; Braaten, Tonje; Knüppel, Sven; Johansson, Ingegerd; van Eeuwijk, Fred A.; Boshuizen, Hendriek

    2014-01-01

    In epidemiologic studies, measurement error in dietary variables often attenuates association between dietary intake and disease occurrence. To adjust for the attenuation caused by error in dietary intake, regression calibration is commonly used. To apply regression calibration, unbiased reference measurements are required. Short-term reference measurements for foods that are not consumed daily contain excess zeroes that pose challenges in the calibration model. We adapted two-part regression calibration model, initially developed for multiple replicates of reference measurements per individual to a single-replicate setting. We showed how to handle excess zero reference measurements by two-step modeling approach, how to explore heteroscedasticity in the consumed amount with variance-mean graph, how to explore nonlinearity with the generalized additive modeling (GAM) and the empirical logit approaches, and how to select covariates in the calibration model. The performance of two-part calibration model was compared with the one-part counterpart. We used vegetable intake and mortality data from European Prospective Investigation on Cancer and Nutrition (EPIC) study. In the EPIC, reference measurements were taken with 24-hour recalls. For each of the three vegetable subgroups assessed separately, correcting for error with an appropriately specified two-part calibration model resulted in about three fold increase in the strength of association with all-cause mortality, as measured by the log hazard ratio. Further found is that the standard way of including covariates in the calibration model can lead to over fitting the two-part calibration model. Moreover, the extent of adjusting for error is influenced by the number and forms of covariates in the calibration model. For episodically consumed foods, we advise researchers to pay special attention to response distribution, nonlinearity, and covariate inclusion in specifying the calibration model. PMID:25402487

  15. [3D-imaging and analysis for plastic surgery by smartphone and tablet: an alternative to professional systems?].

    PubMed

    Koban, K C; Leitsch, S; Holzbach, T; Volkmer, E; Metz, P M; Giunta, R E

    2014-04-01

    A new approach of using photographs from smartphones for three-dimensional (3D) imaging was introduced besides the standard high quality 3D camera systems. In this work, we investigated different capture preferences and compared the accuracy of this 3D reconstruction method with manual tape measurement and an established commercial 3D camera system. The facial region of one plastic mannequin head was labelled with 21 landmarks. A 3D reference model was captured with the Vectra 3D Imaging System®. In addition, 3D imaging was executed with the Autodesk 123d Catch® application using 16, 12, 9, 6 and 3 pictures from Apple® iPhone 4 s® and iPad® 3rd generation. The accuracy of 3D reconstruction was measured in 2 steps. First, 42 distance measurements from manual tape measurement and the 2 digital systems were compared. Second, the surface-to-surface deviation of different aesthetic units from the Vectra® reference model to Catch® generated models was analysed. For each 3D system the capturing and processing time was measured. The measurement showed no significant (p>0.05) difference between manual tape measurement and both digital distances from the Catch® application and Vectra®. Surface-to-surface deviation to the Vectra® reference model showed sufficient results for the 3D reconstruction of Catch® with 16, 12 and 9 picture sets. Use of 6 and 3 pictures resulted in large deviations. Lateral aesthetic units showed higher deviations than central units. Catch® needed 5 times longer to capture and compute 3D models (average 10 min vs. 2 min). The Autodesk 123d Catch® computed models suggests good accuracy of the 3D reconstruction for a standard mannequin model, in comparison to manual tape measurement and the surface-to-surface analysis with a 3D reference model. However, the prolonged capture time with multiple pictures is prone to errors. Further studies are needed to investigate its application and quality in capturing volunteer models. Soon mobile applications may offer an alternative for plastic surgeons to today's cost intensive, stationary 3D camera systems. © Georg Thieme Verlag KG Stuttgart · New York.

  16. Secondary analysis of anthropometric data from a South African national food consumption survey, using different growth reference standards.

    PubMed

    Bosman, L; Herselman, M G; Kruger, H S; Labadarios, D

    2011-11-01

    The National Center for Health Statistics (NCHS) references were used to analyse anthropometric data from the 1999 National Food Consumption Survey (NFCS) of South Africa. Since then, however, The Centers for Disease Control and Prevention (CDC) 2000 reference and the World Health Organization (WHO) 2006 standards were released. It was anticipated that these reference and standards may lead to differences in the previous estimates of stunting, wasting, underweight and obesity in the study population. The aim was to compare the anthropometric status of children using the 1977 NCHS, the 2000 CDC growth references and the 2006 WHO standards. All children 12-60 months of age with a complete set of anthropometric data were included in the analyses. Data for 1,512 children were analysed with SAS 9.1 for Windows. A Z-score was calculated for each child for weight-for-age (W/A), weight-for-length/height (W/H), length/height-for-age (H/A) and body mass index (BMI)-for-age, using each of the three reference or standards for comparison. The prevalence of stunting, obesity and overweight were significantly higher and the prevalence of underweight and wasting were lower when using the WHO standards compared to the NCHS and the CDC references. The higher than previously established prevalence of stunting at 20.1% and combined overweight/obesity at 30% poses a challenge to South African policy makers to implement nutrition programmes to decrease the prevalence of both stunting and overweight. The 2006 WHO growth standard should be the standard used for assessment of growth of infants and children younger than 5 years in developing countries.

  17. Developing and Testing a Robust, Multi-Scale Framework for the Recovery of Longleaf Pine Understory Communities

    DTIC Science & Technology

    2015-05-01

    Model averaging for species richness on post-agricultural sites (1000 m2) with a landscape radius of 150 m. Table 3.4.8. Model selection for species ... richness on post-agricultural sites (1000 m2) with a landscape radius of 150 m. Table 3.4.9. Model averaging for proportion of reference species on...Direct, indirect, and total standardized effects on species richness . Table 4.1.1. Species and number of seeds added to the experimental plots at

  18. The reference individual of radiation protection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eckerman, K.F.; Cristy, M.

    1995-12-31

    The 70-kg {open_quotes}standard man{close_quotes} representing a typical Western adult male has been used in physiological models since at least the 1920s. In 1949 at the Chalk River conference, health physicists from the U.S., UK, and Canada agreed on the concept of a standard man to facilitate comparison of internal dose estimates. The 70-kg standard man included specifications of the masses of 25 organs and tissues, total body content of 15 elements, total water intake and output, water content of the body, and some anatomical and physiological data for the respiratory and gastrointestinal tracts. In 1959, in its Publication 2{sup 2}more » on permissible doses for internal radiation the International Commission on Radiological Protection (ICRP) modified standard man. In 1963 the ICRP established a task group to revise and extend the standard man concept. The name was changed later to Reference Man and the task group`s work was published in 1975 as ICRP Publication 23{sup 3}. Publication 23 similar to Publication 2, updates and documents the sources of the data. Data on women, children, and fetuses were also collected, where available, but these data were limited primarily to anatomical data and only a few reference values were established for these groups. Information assembled during the course of the effort on the Reference Man report was used at Oak Ridge National Laboratory (ORNL) to construct a mathematical representation of the body (a phantom) that was suitable for use with Monte Carlo methods in the calculation of organ doses. That effort was undertaken to improve estimates of dose from photon-emitting radionuclides residing within organs, so-called internal emitters. The phantom, although updated throughout the years, remains today as the basis for organ dose estimates in nuclear medicine and radiation protection and underlies the radiation risk data derived from the epidemiologic studies of the atomic bomb survivors of Hiroshima and Nagasaki.« less

  19. Validity of linear measurements of the jaws using ultralow-dose MDCT and the iterative techniques of ASIR and MBIR.

    PubMed

    Al-Ekrish, Asma'a A; Al-Shawaf, Reema; Schullian, Peter; Al-Sadhan, Ra'ed; Hörmann, Romed; Widmann, Gerlig

    2016-10-01

    To assess the comparability of linear measurements of dental implant sites recorded from multidetector computed tomography (MDCT) images obtained using standard-dose filtered backprojection (FBP) technique with those from various ultralow doses combined with FBP, adaptive statistical iterative reconstruction (ASIR), and model-based iterative reconstruction (MBIR) techniques. The results of the study may contribute to MDCT dose optimization for dental implant site imaging. MDCT scans of two cadavers were acquired using a standard reference protocol and four ultralow-dose test protocols (TP). The volume CT dose index of the different dose protocols ranged from a maximum of 30.48-36.71 mGy to a minimum of 0.44-0.53 mGy. All scans were reconstructed using FBP, ASIR-50, ASIR-100, and MBIR, and either a bone or standard reconstruction kernel. Linear measurements were recorded from standardized images of the jaws by two examiners. Intra- and inter-examiner reliability of the measurements were analyzed using Cronbach's alpha and inter-item correlation. Agreement between the measurements obtained with the reference-dose/FBP protocol and each of the test protocols was determined with Bland-Altman plots and linear regression. Statistical significance was set at a P-value of 0.05. No systematic variation was found between the linear measurements obtained with the reference protocol and the other imaging protocols. The only exceptions were TP3/ASIR-50 (bone kernel) and TP4/ASIR-100 (bone and standard kernels). The mean measurement differences between these three protocols and the reference protocol were within ±0.1 mm, with the 95 % confidence interval limits being within the range of ±1.15 mm. A nearly 97.5 % reduction in dose did not significantly affect the height and width measurements of edentulous jaws regardless of the reconstruction algorithm used.

  20. Chemical thermodynamic data. 1. The concept of links to the chemical elements and the historical development of key thermodynamic data

    NASA Astrophysics Data System (ADS)

    Wolery, Thomas J.; Jové Colón, Carlos F.

    2017-09-01

    Chemical thermodynamic data remain a keystone for geochemical modeling and reactive transport simulation as applied to an increasing number of applications in the earth sciences, as well as applications in other areas including metallurgy, material science, and industrial process design. The last century has seen the development of a large body of thermodynamic data and a number of major compilations. The past several decades have seen the development of thermodynamic databases in digital form designed to support computer calculations. However, problems with thermodynamic data appear to be persistent. One problem pertains to the use of inconsistent primary key reference data. Such data pertain to elemental reference forms and key, stoichiometrically simple chemical species including metal oxides, CO2, water, and aqueous species such as Na+ and Cl-. A consistent set of primary key data (standard Gibbs energies, standard enthalpies, and standard entropies for key chemical species) for 298.15 K and 1 bar pressure is essential. Thermochemical convention is to define the standard Gibbs energy and the standard enthalpy of an individual chemical species in terms of formation from reference forms of the constituent chemical elements. We propose a formal concept of "links" to the elemental reference forms. This concept involves a documented understanding of all reactions and calculations leading to values for a formation property (standard Gibbs energy or enthalpy). A valid link consists of two parts: (a) the path of reactions and corrections and (b) the associated data, which are key data. Such a link differs from a bare "key" or "reference" datum in that it requires additional information. Some or all of its associated data may also be key data. In evaluating a reported thermodynamic datum, one should identify the links to the chemical elements, a process which can be time-consuming and which may lead to a dead end (an incomplete link). The use of two or more inconsistent links to the same elemental reference form in a thermodynamic database will result in an inconsistency in the database. Thus, in constructing a database, it is important to establish a set of reliable links (generally resulting in a set of primary reference data) and then correct all data adopted subsequently for consistency with that set. Recommended values of key data have not been constant through history. We review some of this history through the lens of major compilations and other influential reports, and note a number of problem areas. Finally, we illustrate the concepts developed in this paper by applying them to some key species of geochemical interest, including liquid water; quartz and aqueous silica; and gibbsite, corundum, and the aqueous aluminum ion.

  1. Predicting acute uncomplicated urinary tract infection in women: a systematic review of the diagnostic accuracy of symptoms and signs

    PubMed Central

    2010-01-01

    Background Acute urinary tract infections (UTI) are one of the most common bacterial infections among women presenting to primary care. However, there is a lack of consensus regarding the optimal reference standard threshold for diagnosing UTI. The objective of this systematic review is to determine the diagnostic accuracy of symptoms and signs in women presenting with suspected UTI, across three different reference standards (102 or 103 or 105 CFU/ml). We also examine the diagnostic value of individual symptoms and signs combined with dipstick test results in terms of clinical decision making. Methods Searches were performed through PubMed (1966 to April 2010), EMBASE (1973 to April 2010), Cochrane library (1973 to April 2010), Google scholar and reference checking. Studies that assessed the diagnostic accuracy of symptoms and signs of an uncomplicated UTI using a urine culture from a clean-catch or catherised urine specimen as the reference standard, with a reference standard of at least ≥ 102 CFU/ml were included. Synthesised data from a high quality systematic review were used regarding dipstick results. Studies were combined using a bivariate random effects model. Results Sixteen studies incorporating 3,711 patients are included. The weighted prior probability of UTI varies across diagnostic threshold, 65.1% at ≥ 102 CFU/ml; 55.4% at ≥ 103 CFU/ml and 44.8% at ≥ 102 CFU/ml ≥ 105 CFU/ml. Six symptoms are identified as useful diagnostic symptoms when a threshold of ≥ 102 CFU/ml is the reference standard. Presence of dysuria (+LR 1.30 95% CI 1.20-1.41), frequency (+LR 1.10 95% CI 1.04-1.16), hematuria (+LR 1.72 95%CI 1.30-2.27), nocturia (+LR 1.30 95% CI 1.08-1.56) and urgency (+LR 1.22 95% CI 1.11-1.34) all increase the probability of UTI. The presence of vaginal discharge (+LR 0.65 95% CI 0.51-0.83) decreases the probability of UTI. Presence of hematuria has the highest diagnostic utility, raising the post-test probability of UTI to 75.8% at ≥ 102 CFU/ml and 67.4% at ≥ 103 CFU/ml. Probability of UTI increases to 93.3% and 90.1% at ≥ 102 CFU/ml and ≥ 103 CFU/ml respectively when presence of hematuria is combined with a positive dipstick result for nitrites. Subgroup analysis shows improved diagnostic accuracy using lower reference standards ≥ 102 CFU/ml and ≥ 103 CFU/ml. Conclusions Individual symptoms and signs have a modest ability to raise the pretest-risk of UTI. Diagnostic accuracy improves considerably when combined with dipstick tests particularly tests for nitrites. PMID:20969801

  2. Predicting acute uncomplicated urinary tract infection in women: a systematic review of the diagnostic accuracy of symptoms and signs.

    PubMed

    Giesen, Leonie G M; Cousins, Gráinne; Dimitrov, Borislav D; van de Laar, Floris A; Fahey, Tom

    2010-10-24

    Acute urinary tract infections (UTI) are one of the most common bacterial infections among women presenting to primary care. However, there is a lack of consensus regarding the optimal reference standard threshold for diagnosing UTI. The objective of this systematic review is to determine the diagnostic accuracy of symptoms and signs in women presenting with suspected UTI, across three different reference standards (10(2) or 10(3) or 10(5) CFU/ml). We also examine the diagnostic value of individual symptoms and signs combined with dipstick test results in terms of clinical decision making. Searches were performed through PubMed (1966 to April 2010), EMBASE (1973 to April 2010), Cochrane library (1973 to April 2010), Google scholar and reference checking.Studies that assessed the diagnostic accuracy of symptoms and signs of an uncomplicated UTI using a urine culture from a clean-catch or catherised urine specimen as the reference standard, with a reference standard of at least ≥ 10(2) CFU/ml were included. Synthesised data from a high quality systematic review were used regarding dipstick results. Studies were combined using a bivariate random effects model. Sixteen studies incorporating 3,711 patients are included. The weighted prior probability of UTI varies across diagnostic threshold, 65.1% at ≥ 10(2) CFU/ml; 55.4% at ≥ 10(3) CFU/ml and 44.8% at ≥ 10(2) CFU/ml ≥ 10(5) CFU/ml. Six symptoms are identified as useful diagnostic symptoms when a threshold of ≥ 10(2) CFU/ml is the reference standard. Presence of dysuria (+LR 1.30 95% CI 1.20-1.41), frequency (+LR 1.10 95% CI 1.04-1.16), hematuria (+LR 1.72 95%CI 1.30-2.27), nocturia (+LR 1.30 95% CI 1.08-1.56) and urgency (+LR 1.22 95% CI 1.11-1.34) all increase the probability of UTI. The presence of vaginal discharge (+LR 0.65 95% CI 0.51-0.83) decreases the probability of UTI. Presence of hematuria has the highest diagnostic utility, raising the post-test probability of UTI to 75.8% at ≥ 10(2) CFU/ml and 67.4% at ≥ 10(3) CFU/ml. Probability of UTI increases to 93.3% and 90.1% at ≥ 10(2) CFU/ml and ≥ 10(3) CFU/ml respectively when presence of hematuria is combined with a positive dipstick result for nitrites. Subgroup analysis shows improved diagnostic accuracy using lower reference standards ≥ 10(2) CFU/ml and ≥ 10(3) CFU/ml. Individual symptoms and signs have a modest ability to raise the pretest-risk of UTI. Diagnostic accuracy improves considerably when combined with dipstick tests particularly tests for nitrites.

  3. Evaluation of a 6-wire thermocouple psychrometer for determination of in-situ water potentials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Loskot, C.L.; Rousseau, J.P.; Kurzmack, M.A.

    1994-12-31

    A 6-wire, Peltier-type thermocouple psychrometer was designed and evaluated by the U.S. Geological Survey for monitoring in-situ water potentials in dry-drilled boreholes in the unsaturated zone at Yucca Mountain, Nye County, Nevada. The psychrometer consists of a wet-bulb, chromel-constantan, sensing junction and a separate dry-bulb, copper-constantan, reference junction. Two additional reference junctions are formed where the chromel and constantan wires of the wet-bulb sensing junction are soldered to separate, paired, copper, lead wires. In contrast, in the standard 3-wire thermocouple psychrometer, both the wet bulb and dry bulb share a common wire. The new design has resulted in a psychrometermore » that has an expanded range and greater reliability, sensitivity, and accuracy compared to the standard model.« less

  4. Assessing the impact of non-tidal atmospheric loading on a Kalman filter-based terrestrial reference frame

    NASA Astrophysics Data System (ADS)

    Abbondanza, Claudio; Altamimi, Zuheir; Chin, Toshio; Collilieux, Xavier; Dach, Rolf; Gross, Richard; Heflin, Michael; König, Rolf; Lemoine, Frank; Macmillan, Dan; Parker, Jay; van Dam, Tonie; Wu, Xiaoping

    2014-05-01

    The International Terrestrial Reference Frame (ITRF) adopts a piece-wise linear model to parameterize regularized station positions and velocities. The space-geodetic (SG) solutions from VLBI, SLR, GPS and DORIS used as input in the ITRF combination process account for tidal loading deformations, but ignore the non-tidal part. As a result, the non-linear signal observed in the time series of SG-derived station positions in part reflects non-tidal loading displacements not introduced in the SG data reduction. In this analysis, we assess the impact of non-tidal atmospheric loading (NTAL) corrections on the TRF computation. Focusing on the a-posteriori approach, (i) the NTAL model derived from the National Centre for Environmental Prediction (NCEP) surface pressure is removed from the SINEX files of the SG solutions used as inputs to the TRF determinations; (ii) adopting a Kalman-filter based approach, two distinct linear TRFs are estimated combining the 4 SG solutions with (corrected TRF solution) and without the NTAL displacements (standard TRF solution). Linear fits (offset and atmospheric velocity) of the NTAL displacements removed during step (i) are estimated accounting for the station position discontinuities introduced in the SG solutions and adopting different weighting strategies. The NTAL-derived (atmospheric) velocity fields are compared to those obtained from the TRF reductions during step (ii). The consistency between the atmospheric and the TRF-derived velocity fields is examined. We show how the presence of station position discontinuities in SG solutions degrades the agreement between the velocity fields and compare the effect of different weighting structure adopted while estimating the linear fits to the NTAL displacements. Finally, we evaluate the effect of restoring the atmospheric velocities determined through the linear fits of the NTAL displacements to the single-technique linear reference frames obtained by stacking the standard SG SINEX files. Differences between the velocity fields obtained restoring the NTAL displacements and the standard stacked linear reference frames are discussed.

  5. Dimensional accuracy of jaw scans performed on alginate impressions or stone models: A practice-oriented study.

    PubMed

    Vogel, Annike B; Kilic, Fatih; Schmidt, Falko; Rübel, Sebastian; Lapatki, Bernd G

    2015-07-01

    Digital jaw models offer more extensive possibilities for analysis than casts and make it easier to share and archive relevant information. The aim of this study was to compare the dimensional accuracy of scans performed on alginate impressions and on stone models to reference scans performed on underlying resin models. Precision spheres 5 mm in diameter were occlusally fitted to the sites of the first premolars and first molars on a pair of jaw models fabricated from resin. A structured-light scanner was used for digitization. Once the two reference models had been scanned, alginate impressions were taken and scanned after no later than 1 h. A third series of scans was performed on type III stone models derived from the impressions. All scans were analyzed by performing five repeated measurements to determine the distances between the various sphere centers. Compared to the reference scans, the stone-model scans were larger by a mean of 73.6 µm (maxilla) or 65.2 µm (mandible). The impression scans were only larger by 7.7 µm (maxilla) or smaller by 0.7 µm (mandible). Median standard deviations over the five repeated measurements of 1.0 µm for the reference scans, 2.35 µm for the impression scans, and 2.0 µm for the stone-model scans indicate that the values measured in this study were adequately reproducible. Alginate impressions can be suitably digitized by structured-light scanning and offer considerably better dimensional accuracy than stone models. Apparently, however, both impression scans and stone-model scans can offer adequate precision for orthodontic purposes. The main issue of impression scans (which is incomplete representation of model surfaces) is being systematically explored in a follow-up study.

  6. Archetype Model-Driven Development Framework for EHR Web System

    PubMed Central

    Kimura, Eizen; Ishihara, Ken

    2013-01-01

    Objectives This article describes the Web application framework for Electronic Health Records (EHRs) we have developed to reduce construction costs for EHR sytems. Methods The openEHR project has developed clinical model driven architecture for future-proof interoperable EHR systems. This project provides the specifications to standardize clinical domain model implementations, upon which the ISO/CEN 13606 standards are based. The reference implementation has been formally described in Eiffel. Moreover C# and Java implementations have been developed as reference. While scripting languages had been more popular because of their higher efficiency and faster development in recent years, they had not been involved in the openEHR implementations. From 2007, we have used the Ruby language and Ruby on Rails (RoR) as an agile development platform to implement EHR systems, which is in conformity with the openEHR specifications. Results We implemented almost all of the specifications, the Archetype Definition Language parser, and RoR scaffold generator from archetype. Although some problems have emerged, most of them have been resolved. Conclusions We have provided an agile EHR Web framework, which can build up Web systems from archetype models using RoR. The feasibility of the archetype model to provide semantic interoperability of EHRs has been demonstrated and we have verified that that it is suitable for the construction of EHR systems. PMID:24523991

  7. Physical fitness reference standards in European children: the IDEFICS study.

    PubMed

    De Miguel-Etayo, P; Gracia-Marco, L; Ortega, F B; Intemann, T; Foraita, R; Lissner, L; Oja, L; Barba, G; Michels, N; Tornaritis, M; Molnár, D; Pitsiladis, Y; Ahrens, W; Moreno, L A

    2014-09-01

    A low fitness status during childhood and adolescence is associated with important health-related outcomes, such as increased future risk for obesity and cardiovascular diseases, impaired skeletal health, reduced quality of life and poor mental health. Fitness reference values for adolescents from different countries have been published, but there is a scarcity of reference values for pre-pubertal children in Europe, using harmonised measures of fitness in the literature. The IDEFICS study offers a good opportunity to establish normative values of a large set of fitness components from eight European countries using common and well-standardised methods in a large sample of children. Therefore, the aim of this study is to report sex- and age-specific fitness reference standards in European children. Children (10,302) aged 6-10.9 years (50.7% girls) were examined. The test battery included: the flamingo balance test, back-saver sit-and-reach test (flexibility), handgrip strength test, standing long jump test (lower-limb explosive strength) and 40-m sprint test (speed). Moreover, cardiorespiratory fitness was assessed by a 20-m shuttle run test. Percentile curves for the 1st, 3rd, 10th, 25th, 50th, 75th, 90th, 97th and 99th percentiles were calculated using the General Additive Model for Location Scale and Shape (GAMLSS). Our results show that boys performed better than girls in speed, lower- and upper-limb strength and cardiorespiratory fitness, and girls performed better in balance and flexibility. Older children performed better than younger children, except for cardiorespiratory fitness in boys and flexibility in girls. Our results provide for the first time sex- and age-specific physical fitness reference standards in European children aged 6-10.9 years.

  8. 36 CFR 400.1 - Cross-references to employees' ethical conduct standards, financial disclosure regulations and...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...' ethical conduct standards, financial disclosure regulations and other conduct rules. 400.1 Section 400.1... CONDUCT § 400.1 Cross-references to employees' ethical conduct standards, financial disclosure regulations... executive branch-wide standards of ethical conduct and financial disclosure regulations at 5 CFR parts 2634...

  9. 24 CFR 0.1 - Cross-reference to employees ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... ethical conduct standards and financial disclosure regulations. 0.1 Section 0.1 Housing and Urban... Cross-reference to employees ethical conduct standards and financial disclosure regulations. Employees...-wide standards of ethical conduct at 5 CFR part 2635, the Department's regulation at 5 CFR part 7501...

  10. 24 CFR 0.1 - Cross-reference to employees ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... ethical conduct standards and financial disclosure regulations. 0.1 Section 0.1 Housing and Urban... Cross-reference to employees ethical conduct standards and financial disclosure regulations. Employees...-wide standards of ethical conduct at 5 CFR part 2635, the Department's regulation at 5 CFR part 7501...

  11. 36 CFR 400.1 - Cross-references to employees' ethical conduct standards, financial disclosure regulations and...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...' ethical conduct standards, financial disclosure regulations and other conduct rules. 400.1 Section 400.1... CONDUCT § 400.1 Cross-references to employees' ethical conduct standards, financial disclosure regulations... executive branch-wide standards of ethical conduct and financial disclosure regulations at 5 CFR parts 2634...

  12. 41 CFR 105-735.1 - Cross-references to employee ethical conduct standards, financial disclosure regulations, and...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... employee ethical conduct standards, financial disclosure regulations, and other regulations. 105-735.1... CONDUCT § 105-735.1 Cross-references to employee ethical conduct standards, financial disclosure... executive branch-wide standards of ethical conduct at 5 CFR part 2635, GSA's regulations at 5 CFR part 6701...

  13. 29 CFR 1600.101 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 4 2010-07-01 2010-07-01 false Cross-reference to employee ethical conduct standards and... to employee ethical conduct standards and financial disclosure regulations. Employees of the Equal Employment Opportunity Commission (EEOC) are subject to the executive branch-wide Standards of Ethical...

  14. 38 CFR 0.735-10 - Cross-reference to employee ethical and other conduct standards and financial disclosure...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... employee ethical and other conduct standards and financial disclosure regulations. 0.735-10 Section 0.735... ETHICAL CONDUCT, AND RELATED RESPONSIBILITIES Standards of Ethical Conduct and Related Responsibilities of Employees § 0.735-10 Cross-reference to employee ethical and other conduct standards and financial...

  15. 38 CFR 0.735-10 - Cross-reference to employee ethical and other conduct standards and financial disclosure...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... employee ethical and other conduct standards and financial disclosure regulations. 0.735-10 Section 0.735... ETHICAL CONDUCT, AND RELATED RESPONSIBILITIES Standards of Ethical Conduct and Related Responsibilities of Employees § 0.735-10 Cross-reference to employee ethical and other conduct standards and financial...

  16. 36 CFR 400.1 - Cross-references to employees' ethical conduct standards, financial disclosure regulations and...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...' ethical conduct standards, financial disclosure regulations and other conduct rules. 400.1 Section 400.1... CONDUCT § 400.1 Cross-references to employees' ethical conduct standards, financial disclosure regulations... executive branch-wide standards of ethical conduct and financial disclosure regulations at 5 CFR parts 2634...

  17. 36 CFR 400.1 - Cross-references to employees' ethical conduct standards, financial disclosure regulations and...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...' ethical conduct standards, financial disclosure regulations and other conduct rules. 400.1 Section 400.1... CONDUCT § 400.1 Cross-references to employees' ethical conduct standards, financial disclosure regulations... executive branch-wide standards of ethical conduct and financial disclosure regulations at 5 CFR parts 2634...

  18. 24 CFR 0.1 - Cross-reference to employees ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... ethical conduct standards and financial disclosure regulations. 0.1 Section 0.1 Housing and Urban... Cross-reference to employees ethical conduct standards and financial disclosure regulations. Employees...-wide standards of ethical conduct at 5 CFR part 2635, the Department's regulation at 5 CFR part 7501...

  19. 24 CFR 0.1 - Cross-reference to employees ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... ethical conduct standards and financial disclosure regulations. 0.1 Section 0.1 Housing and Urban... Cross-reference to employees ethical conduct standards and financial disclosure regulations. Employees...-wide standards of ethical conduct at 5 CFR part 2635, the Department's regulation at 5 CFR part 7501...

  20. 24 CFR 0.1 - Cross-reference to employees ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... ethical conduct standards and financial disclosure regulations. 0.1 Section 0.1 Housing and Urban... Cross-reference to employees ethical conduct standards and financial disclosure regulations. Employees...-wide standards of ethical conduct at 5 CFR part 2635, the Department's regulation at 5 CFR part 7501...

  1. A new definition for an old entity: improved definition of mitral valve prolapse using three-dimensional echocardiography and color-coded parametric models.

    PubMed

    Addetia, Karima; Mor-Avi, Victor; Weinert, Lynn; Salgo, Ivan S; Lang, Roberto M

    2014-01-01

    Differentiating between mitral valve (MV) prolapse (MVP) and MV billowing (MVB) on two-dimensional echocardiography is challenging. The aim of this study was to test the hypothesis that color-coded models of maximal leaflet displacement from the annular plane into the atrium derived from three-dimensional transesophageal echocardiography would allow discrimination between these lesions. Three-dimensional transesophageal echocardiographic imaging of the MV was performed in 50 patients with (n = 38) and without (n = 12) degenerative MV disease. Definitive diagnosis of MVP versus MVB was made using inspection of dynamic three-dimensional renderings and multiple two-dimensional cut planes extracted from three-dimensional data sets. This was used as a reference standard to test an alternative approach, wherein the color-coded parametric models were inspected for integrity of the coaptation line and location of the maximally displaced portion of the leaflet. Diagnostic interpretations of these models by two independent readers were compared with the reference standard. In all cases of MVP, the color-coded models depicted loss of integrity of the coaptation line and maximal leaflet displacement extending to the coaptation line. MVB was depicted by preserved leaflet apposition with maximal displacement away from the coaptation line. Interpretation of the 50 color-coded models by novice readers took 5 to 10 min and resulted in good agreement with the reference technique (κ = 0.81 and κ = 0.73 for the two readers). Three-dimensional color-coded models provide a static display of MV leaflet displacement, allowing differentiation between MVP and MVB, without the need to inspect multiple planes and while taking into account the saddle shape of the mitral annulus. Copyright © 2014 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.

  2. STANDARD REFERENCE MATERIALS FOR THE POLYMERS INDUSTRY.

    PubMed

    McDonough, Walter G; Orski, Sara V; Guttman, Charles M; Migler, Kalman D; Beers, Kathryn L

    2016-01-01

    The National Institute of Standards and Technology (NIST) provides science, industry, and government with a central source of well-characterized materials certified for chemical composition or for some chemical or physical property. These materials are designated Standard Reference Materials ® (SRMs) and are used to calibrate measuring instruments, to evaluate methods and systems, or to produce scientific data that can be referred readily to a common base. In this paper, we discuss the history of polymer based SRMs, their current status, and challenges and opportunities to develop new standards to address industrial measurement challenges.

  3. Polyfluorinated substances in abiotic standard reference materials

    EPA Science Inventory

    The National Institute of Standards and Technology (NIST) has a wide range of Standard Reference Materials (SRMs) which have values assigned for legacy organic pollutants and toxic elements. Existing SRMs serve as homogenous materials that can be used for method development, meth...

  4. Employment references: defamation law in the clinical laboratory.

    PubMed

    Parks, D G

    1993-01-01

    The law of defamation and the risks involved in issuing employment references are discussed. A hypothetical scenario is used to illustrate the legal standards governing the tort of defamation and to apply those standards to employment references. Practical suggestions for a "controlled reference" policy are provided, with the objective of allowing for responsible exchange of employment information and avoiding a defamation lawsuit.

  5. Growth References of Preschool Children Based on the Taiwan Birth Cohort Study and Compared to World Health Organization Growth Standards.

    PubMed

    Li, Yi-Fan; Lin, Shio-Jean; Lin, Kuan-Chia; Chiang, Tung-Liang

    2016-02-01

    To develop new growth references for height, weight, and body mass index (BMI) for children aged 0-5 years in the Taiwan Birth Cohort Study (TBCS) and to compare these references with both 1997 Taiwan references and World Health Organization (WHO) standards. Data were obtained from the TBCS of a nationally representative sample of 24,200 children. A total of 18,466 children completed the baseline survey at 6 months of age and three follow-up surveys at 18 months, 3 years, and 5.5 years of age. The modified LMS method was used to construct percentile curves by sex, including length/height for age, weight for age, and BMI for age. TBCS children of both sexes were shorter and lighter at birth compared with 1997 Taiwan references and WHO standards. The growth patterns of TBCS children were close to those of the 1997 Taiwan references after 6 months of age. Compared with WHO standards, however, TBCS children were heavier after 6 months of age. This study has developed TBCS references to monitor the growth of children in Taiwan, whose weight growth patterns differed from those "prescribed" by WHO standards. Copyright © 2016. Published by Elsevier B.V.

  6. 78 FR 37696 - Federal Acquisition Regulation; Updated Postretirement Benefit (PRB) References

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-21

    ... that were deleted in the Financial Accounting Standards Board's (FASB's) Accounting Standards Codification (ASC) of Generally Accepted Accounting Principles (GAAP). The references no longer exist in the..., 2012, to replace the obsolete references to paragraphs 110, 112, and 113 of Financial Accounting...

  7. Predictive Accuracy of Sweep Frequency Impedance Technology in Identifying Conductive Conditions in Newborns.

    PubMed

    Aithal, Venkatesh; Kei, Joseph; Driscoll, Carlie; Murakoshi, Michio; Wada, Hiroshi

    2018-02-01

    Diagnosing conductive conditions in newborns is challenging for both audiologists and otolaryngologists. Although high-frequency tympanometry (HFT), acoustic stapedial reflex tests, and wideband absorbance measures are useful diagnostic tools, there is performance measure variability in their detection of middle ear conditions. Additional diagnostic sensitivity and specificity measures gained through new technology such as sweep frequency impedance (SFI) measures may assist in the diagnosis of middle ear dysfunction in newborns. The purpose of this study was to determine the test performance of SFI to predict the status of the outer and middle ear in newborns against commonly used reference standards. Automated auditory brainstem response (AABR), HFT (1000 Hz), transient evoked otoacoustic emission (TEOAE), distortion product otoacoustic emission (DPOAE), and SFI tests were administered to the study sample. A total of 188 neonates (98 males and 90 females) with a mean gestational age of 39.4 weeks were included in the sample. Mean age at the time of testing was 44.4 hr. Diagnostic accuracy of SFI was assessed in terms of its ability to identify conductive conditions in neonates when compared with nine different reference standards (including four single tests [AABR, HFT, TEOAE, and DPOAE] and five test batteries [HFT + DPOAE, HFT + TEOAE, DPOAE + TEOAE, DPOAE + AABR, and TEOAE + AABR]), using receiver operating characteristic (ROC) analysis and traditional test performance measures such as sensitivity and specificity. The test performance of SFI against the test battery reference standard of HFT + DPOAE and single reference standard of HFT was high with an area under the ROC curve (AROC) of 0.87 and 0.82, respectively. Although the HFT + DPOAE test battery reference standard performed better than the HFT reference standard in predicting middle ear conductive conditions in neonates, the difference in AROC was not significant. Further analysis revealed that the highest sensitivity and specificity for SFI (86% and 88%, respectively) was obtained when compared with the reference standard of HFT + DPOAE. Among the four single reference standards, SFI had the highest sensitivity and specificity (76% and 88%, respectively) when compared against the HFT reference standard. The high test performance of SFI against the HFT and HFT + DPOAE reference standards indicates that the SFI measure has appropriate diagnostic accuracy in detection of conductive conditions in newborns. Hence, the SFI test could be used as adjunct tool to identify conductive conditions in universal newborn hearing screening programs, and can also be used in diagnostic follow-up assessments. American Academy of Audiology

  8. Bayesian modeling and inference for diagnostic accuracy and probability of disease based on multiple diagnostic biomarkers with and without a perfect reference standard.

    PubMed

    Jafarzadeh, S Reza; Johnson, Wesley O; Gardner, Ian A

    2016-03-15

    The area under the receiver operating characteristic (ROC) curve (AUC) is used as a performance metric for quantitative tests. Although multiple biomarkers may be available for diagnostic or screening purposes, diagnostic accuracy is often assessed individually rather than in combination. In this paper, we consider the interesting problem of combining multiple biomarkers for use in a single diagnostic criterion with the goal of improving the diagnostic accuracy above that of an individual biomarker. The diagnostic criterion created from multiple biomarkers is based on the predictive probability of disease, conditional on given multiple biomarker outcomes. If the computed predictive probability exceeds a specified cutoff, the corresponding subject is allocated as 'diseased'. This defines a standard diagnostic criterion that has its own ROC curve, namely, the combined ROC (cROC). The AUC metric for cROC, namely, the combined AUC (cAUC), is used to compare the predictive criterion based on multiple biomarkers to one based on fewer biomarkers. A multivariate random-effects model is proposed for modeling multiple normally distributed dependent scores. Bayesian methods for estimating ROC curves and corresponding (marginal) AUCs are developed when a perfect reference standard is not available. In addition, cAUCs are computed to compare the accuracy of different combinations of biomarkers for diagnosis. The methods are evaluated using simulations and are applied to data for Johne's disease (paratuberculosis) in cattle. Copyright © 2015 John Wiley & Sons, Ltd.

  9. [Impact and state of the art of regional healthcare planning and management guidelines in a local health authority of the Lazio region (Italy)].

    PubMed

    Priori, Maria Rosaria; Barbato, Angelo

    2007-01-01

    The aim of this study was to evaluate the impact of health care planning and management guidelines, elaborated by the Lazio regional healthcare authority, on the organizational structure and operational processes of local health authorities and, more specifically, of the Roma C local health authority. The guidelines are made up of three volumes and mainly describe an operational model, rather than being a set of standard references aimed at standardizing the quality of information low systems in local healthcare authorities. The guidelines are essentially a didactic text, and were elaborated by a consulting firm, Engineering Management Consulting, on behalf of the Lazio regional authority. In the first section, the main concepts are defined, while in subsequent sections, detailed models regarding the specific subject matter are described. Although the guidelines represent a useful tool in the process of converting local health authorities of the Lazio region into "business" organizations, so far they have been of use only in the first phase of assessment of different organizational models for healthcare planning and management. There is still a long way ahead towards defining standard procedures and references for describing activities and costs. This is what should hopefully be achieved briefly and which will necessarily require the introduction of a data warehouse and business intelligence software that will allow monitoring of activities and making short term predictions through the use balanced scorecards and data mining.

  10. A reference model for model-based design of critical infrastructure protection systems

    NASA Astrophysics Data System (ADS)

    Shin, Young Don; Park, Cheol Young; Lee, Jae-Chon

    2015-05-01

    Today's war field environment is getting versatile as the activities of unconventional wars such as terrorist attacks and cyber-attacks have noticeably increased lately. The damage caused by such unconventional wars has also turned out to be serious particularly if targets are critical infrastructures that are constructed in support of banking and finance, transportation, power, information and communication, government, and so on. The critical infrastructures are usually interconnected to each other and thus are very vulnerable to attack. As such, to ensure the security of critical infrastructures is very important and thus the concept of critical infrastructure protection (CIP) has come. The program to realize the CIP at national level becomes the form of statute in each country. On the other hand, it is also needed to protect each individual critical infrastructure. The objective of this paper is to study on an effort to do so, which can be called the CIP system (CIPS). There could be a variety of ways to design CIPS's. Instead of considering the design of each individual CIPS, a reference model-based approach is taken in this paper. The reference model represents the design of all the CIPS's that have many design elements in common. In addition, the development of the reference model is also carried out using a variety of model diagrams. The modeling language used therein is the systems modeling language (SysML), which was developed and is managed by Object Management Group (OMG) and a de facto standard. Using SysML, the structure and operational concept of the reference model are designed to fulfil the goal of CIPS's, resulting in the block definition and activity diagrams. As a case study, the operational scenario of the nuclear power plant while being attacked by terrorists is studied using the reference model. The effectiveness of the results is also analyzed using multiple analysis models. It is thus expected that the approach taken here has some merits over the traditional design methodology of repeating requirements analysis and system design.

  11. 24 CFR 3285.405 - Severe wind zones.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Anchorage Against Wind § 3285.405 Severe wind zones. When any part of a home is installed within 1,500 feet of a coastline in Wind Zones II or III, the manufactured home must be designed for the increased requirements, as specified on the home's data plate (refer...

  12. The Evolution of SCORM to Tin Can API: Implications for Instructional Design

    ERIC Educational Resources Information Center

    Lindert, Lisa; Su, Bude

    2016-01-01

    Integrating and documenting formal and informal learning experiences is challenging using the current Shareable Content Object Reference Model (SCORM) eLearning standard, which limits the media and data that are obtained from eLearning. In response to SCORM's limitations, corporate, military, and academic institutions have collaborated to develop…

  13. Adopting SCORM 1.2 Standards in a Courseware Production Environment

    ERIC Educational Resources Information Center

    Barker, Bradley

    2004-01-01

    The Sharable Content Object Reference Model (SCORM) is a technology framework for Web-based learning technology. Originated by the Department of Defense and accelerated by the Advanced Distributed Learning initiative SCORM was released in January of 2000 (ADL, 2003). The goals of SCORM are to decrease the cost of training, while increasing the…

  14. Calculation of electron Dose Point Kernel in water with GEANT4 for medical application

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guimaraes, C. C.; Sene, F. F.; Martinelli, J. R.

    2009-06-03

    The rapid insertion of new technologies in medical physics in the last years, especially in nuclear medicine, has been followed by a great development of faster Monte Carlo algorithms. GEANT4 is a Monte Carlo toolkit that contains the tools to simulate the problems of particle transport through matter. In this work, GEANT4 was used to calculate the dose-point-kernel (DPK) for monoenergetic electrons in water, which is an important reference medium for nuclear medicine. The three different physical models of electromagnetic interactions provided by GEANT4 - Low Energy, Penelope and Standard - were employed. To verify the adequacy of these models,more » the results were compared with references from the literature. For all energies and physical models, the agreement between calculated DPKs and reported values is satisfactory.« less

  15. Gravitational leptogenesis, reheating, and models of neutrino mass

    NASA Astrophysics Data System (ADS)

    Adshead, Peter; Long, Andrew J.; Sfakianakis, Evangelos I.

    2018-02-01

    Gravitational leptogenesis refers to a class of baryogenesis models in which the matter-antimatter asymmetry of the Universe arises through the standard model lepton-number gravitational anomaly. In these models chiral gravitational waves source a lepton asymmetry in standard model neutrinos during the inflationary epoch. We point out that gravitational leptogenesis can be successful in either the Dirac or Majorana neutrino mass scenario. In the Dirac mass scenario, gravitational leptogenesis predicts a relic abundance of sterile neutrinos that remain out of equilibrium, and the lepton asymmetry carried by the standard model sector is unchanged. In the Majorana mass scenario, the neutrinos participate in lepton-number-violating interactions that threaten to wash out the lepton asymmetry during postinflationary reheating. However, we show that a complete (exponential) washout of the lepton asymmetry is prevented if the lepton-number-violating interactions go out of equilibrium before all of the standard model Yukawa interactions come into equilibrium. The baryon and lepton asymmetries carried by right-chiral quarks and leptons are sequestered from the lepton-number violation, and the washout processes only suppress the predicted baryon asymmetry by a factor of ɛw .o .=±O (0.1 ). The sign of ɛw .o . depends on the model parameters in such a way that a future measurement of the primordial gravitational wave chirality would constrain the scale of lepton-number violation (heavy Majorana neutrino mass).

  16. A reflection and evaluation model of comparative thinking.

    PubMed

    Markman, Keith D; McMullen, Matthew N

    2003-01-01

    This article reviews research on counterfactual, social, and temporal comparisons and proposes a Reflection and Evaluation Model (REM) as an organizing framework. At the heart of the model is the assertion that 2 psychologically distinct modes of mental simulation operate during comparative thinking: reflection, an experiential ("as if") mode of thinking characterized by vividly simulating that information about the comparison standard is true of, or part of, the self; and evaluation, an evaluative mode of thinking characterized by the use of information about the standard as a reference point against which to evaluate one's present standing. Reflection occurs when information about the standard is included in one's self-construal, and evaluation occurs when such information is excluded. The result of reflection is that standard-consistent cognitions about the self become highly accessible, thereby yielding affective assimilation; whereas the result of evaluation is that comparison information is used as a standard against which one's present standing is evaluated, thereby yielding affective contrast. The resulting affect leads to either an increase or decrease in behavioral persistence as a function of the type of task with which one is engaged, and a combination of comparison-derived causal inferences and regulatory focus strategies direct one toward adopting specific future action plans.

  17. Endoscope field of view measurement.

    PubMed

    Wang, Quanzeng; Khanicheh, Azadeh; Leiner, Dennis; Shafer, David; Zobel, Jurgen

    2017-03-01

    The current International Organization for Standardization (ISO) standard (ISO 8600-3: 1997 including Amendment 1: 2003) for determining endoscope field of view (FOV) does not accurately characterize some novel endoscopic technologies such as endoscopes with a close focus distance and capsule endoscopes. We evaluated the endoscope FOV measurement method (the FOV WS method) in the current ISO 8600-3 standard and proposed a new method (the FOV EP method). We compared the two methods by measuring the FOV of 18 models of endoscopes (one device for each model) from seven key international manufacturers. We also estimated the device to device variation of two models of colonoscopes by measuring several hundreds of devices. Our results showed that the FOV EP method was more accurate than the FOV WS method, and could be used for all endoscopes. We also found that the labelled FOV values of many commercial endoscopes are significantly overstated. Our study can help endoscope users understand endoscope FOV and identify a proper method for FOV measurement. This paper can be used as a reference to revise the current endoscope FOV measurement standard.

  18. Endoscope field of view measurement

    PubMed Central

    Wang, Quanzeng; Khanicheh, Azadeh; Leiner, Dennis; Shafer, David; Zobel, Jurgen

    2017-01-01

    The current International Organization for Standardization (ISO) standard (ISO 8600-3: 1997 including Amendment 1: 2003) for determining endoscope field of view (FOV) does not accurately characterize some novel endoscopic technologies such as endoscopes with a close focus distance and capsule endoscopes. We evaluated the endoscope FOV measurement method (the FOVWS method) in the current ISO 8600-3 standard and proposed a new method (the FOVEP method). We compared the two methods by measuring the FOV of 18 models of endoscopes (one device for each model) from seven key international manufacturers. We also estimated the device to device variation of two models of colonoscopes by measuring several hundreds of devices. Our results showed that the FOVEP method was more accurate than the FOVWS method, and could be used for all endoscopes. We also found that the labelled FOV values of many commercial endoscopes are significantly overstated. Our study can help endoscope users understand endoscope FOV and identify a proper method for FOV measurement. This paper can be used as a reference to revise the current endoscope FOV measurement standard. PMID:28663840

  19. Building-up a database of spectro-photometric standards from the UV to the NIR

    NASA Astrophysics Data System (ADS)

    Vernet, J.; Kerber, F.; Mainieri, V.; Rauch, T.; Saitta, F.; D'Odorico, S.; Bohlin, R.; Ivanov, V.; Lidman, C.; Mason, E.; Smette, A.; Walsh, J.; Fosbury, R.; Goldoni, P.; Groot, P.; Hammer, F.; Kaper, L.; Horrobin, M.; Kjaergaard-Rasmussen, P.; Royer, F.

    2010-11-01

    We present results of a project aimed at establishing a set of 12 spectro-photometric standards over a wide wavelength range from 320 to 2500 nm. Currently no such set of standard stars covering the near-IR is available. Our strategy is to extend the useful range of existing well-established optical flux standards (Oke 1990, Hamuy et al. 1992, 1994) into the near-IR by means of integral field spectroscopy with SINFONI at the VLT combined with state-of-the-art white dwarf stellar atmospheric models (TMAP, Holberg et al. 2008). As a solid reference, we use two primary HST standard white dwarfs GD71 and GD153 and one HST secondary standard BD+17 4708. The data were collected through an ESO “Observatory Programme” over ~40 nights between February 2007 and September 2008.

  20. Barrier-free design: a review and critique of the occupational therapy perspective.

    PubMed

    Cooper, B A; Cohen, U; Hasselkus, B R

    1991-04-01

    This review of the occupational therapy literature on barrier-free design identifies both a paucity of related occupational therapy research on the topic and a lack of a common conceptual base with which to guide the development and use of environmental assessments. Nonetheless, two fledgling themes can be extrapolated: the consistent reference to the concepts of accessibility, mobility, function, and safety and an increased awareness among occupational therapists regarding the accessibility standards developed by the American National Standards Institute (ANSI) (ANSI, 1971, 1980). A problem-solving model suggested by designers for the 1979 revision of ANSI standards that incorporates these conceptual themes is described and discussed.

  1. Harmonized Reference Ranges for Circulating Testosterone Levels in Men of Four Cohort Studies in the United States and Europe

    PubMed Central

    Travison, Thomas G.; Vesper, Hubert W.; Orwoll, Eric; Wu, Frederick; Kaufman, Jean Marc; Wang, Ying; Lapauw, Bruno; Fiers, Tom; Matsumoto, Alvin M.

    2017-01-01

    Background: Reference ranges for testosterone are essential for making a diagnosis of hypogonadism in men. Objective: To establish harmonized reference ranges for total testosterone in men that can be applied across laboratories by cross-calibrating assays to a reference method and standard. Population: The 9054 community-dwelling men in cohort studies in the United States and Europe: Framingham Heart Study; European Male Aging Study; Osteoporotic Fractures in Men Study; and Male Sibling Study of Osteoporosis. Methods: Testosterone concentrations in 100 participants in each of the four cohorts were measured using a reference method at Centers for Disease Control and Prevention (CDC). Generalized additive models and Bland-Altman analyses supported the use of normalizing equations for transformation between cohort-specific and CDC values. Normalizing equations, generated using Passing-Bablok regression, were used to generate harmonized values, which were used to derive standardized, age-specific reference ranges. Results: Harmonization procedure reduced intercohort variation between testosterone measurements in men of similar ages. In healthy nonobese men, 19 to 39 years, harmonized 2.5th, 5th, 50th, 95th, and 97.5th percentile values were 264, 303, 531, 852, and 916 ng/dL, respectively. Age-specific harmonized testosterone concentrations in nonobese men were similar across cohorts and greater than in all men. Conclusion: Harmonized normal range in a healthy nonobese population of European and American men, 19 to 39 years, is 264 to 916 ng/dL. A substantial proportion of intercohort variation in testosterone levels is due to assay differences. These data demonstrate the feasibility of generating harmonized reference ranges for testosterone that can be applied to assays, which have been calibrated to a reference method and calibrator. PMID:28324103

  2. Hearing the Sound in the Brain: Influences of Different EEG References.

    PubMed

    Wu, Dan

    2018-01-01

    If the scalp potential signals, the electroencephalogram (EEG), are due to neural "singers" in the brain, how could we listen to them with less distortion? One crucial point is that the data recording on the scalp should be faithful and accurate, thus the choice of reference electrode is a vital factor determining the faithfulness of the data. In this study, music on the scalp derived from data in the brain using three different reference electrodes were compared, including approximate zero reference-reference electrode standardization technique (REST), average reference (AR), and linked mastoids reference (LM). The classic music pieces in waveform format were used as simulated sources inside a head model, and they were forward calculated to scalp as standard potential recordings, i.e., waveform format music from the brain with true zero reference. Then these scalp music was re-referenced into REST, AR, and LM based data, and compared with the original forward data (true zero reference). For real data, the EEG recorded in an orthodontic pain control experiment were utilized for music generation with the three references, and the scale free index (SFI) of these music pieces were compared. The results showed that in the simulation for only one source, different references do not change the music/waveform; for two sources or more, REST provide the most faithful music/waveform to the original ones inside the brain, and the distortions caused by AR and LM were spatial locations of both source and scalp electrode dependent. The brainwave music from the real EEG data showed that REST and AR make the differences of SFI between two states more recognized and found the frontal is the main region that producing the music. In conclusion, REST can reconstruct the true signals approximately, and it can be used to help to listen to the true voice of the neural singers in the brain.

  3. Extensions of the standard model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ramond, P.

    1983-01-01

    In these lectures we focus on several issues that arise in theoretical extensions of the standard model. First we describe the kinds of fermions that can be added to the standard model without affecting known phenomenology. We focus in particular on three types: the vector-like completion of the existing fermions as would be predicted by a Kaluza-Klein type theory, which we find cannot be realistically achieved without some chiral symmetry; fermions which are vector-like by themselves, such as do appear in supersymmetric extensions, and finally anomaly-free chiral sets of fermions. We note that a chiral symmetry, such as the Peccei-Quinnmore » symmetry can be used to produce a vector-like theory which, at scales less than M/sub W/, appears to be chiral. Next, we turn to the analysis of the second hierarchy problem which arises in Grand Unified extensions of the standard model, and plays a crucial role in proton decay of supersymmetric extensions. We review the known mechanisms for avoiding this problem and present a new one which seems to lead to the (family) triplication of the gauge group. Finally, this being a summer school, we present a list of homework problems. 44 references.« less

  4. Determination of Perfluorinated Alkyl Acid Concentrations in Biological Standard Reference Materials

    EPA Science Inventory

    Standard reference materials (SRMs) are homogeneous, well-characterized materials used to validate measurements and improve the quality of analytical data. The National Institute of Standards and Technology (NIST) has a wide range of SRMs that have mass fraction values assigned ...

  5. Standardization of the capillary electrophoresis procedures Capillarys® CDT and Minicap® CDT in comparison to the IFCC reference measurement procedure.

    PubMed

    Schellenberg, François; Humeau, Camille

    2017-06-01

    CDT is at present the most relevant routinely available biological marker of alcohol use and is widely used for screening and monitoring of patients. The lack of standardization leads to specific reference intervals for each procedure. The IFCC working group devoted to CDT demonstrated that the standardization is possible using calibrators assigned to the reference measurement procedure. In this study, we compare the capillary electrophoresis (CE) techniques Capillarys® CDT and Minicap® CDT (Sebia, Lisses, France) to the reference procedure before and after standardization in 126 samples covering the range of CDT measurement. Both capillary electrophoresis procedures show a high correlation (r=0,997) with the reference procedure and the concordance correlation coefficient evaluated according to Mc Bride is "almost perfect" (>0.997 for both CE procedures). The number of results with a relative difference higher than the acceptable difference limit is only 1 for Capillarys® CDT and 5 for Minicap® CDT. These results demonstrate the efficiency of the standardization of CDT measurements for both CE techniques from Sebia, achieved using calibrators assigned to the reference measurement procedure.

  6. [The requirements of standard and conditions of interchangeability of medical articles].

    PubMed

    Men'shikov, V V; Lukicheva, T I

    2013-11-01

    The article deals with possibility to apply specific approaches under evaluation of interchangeability of medical articles for laboratory analysis. The development of standardized analytical technologies of laboratory medicine and formulation of requirements of standards addressed to manufacturers of medical articles the clinically validated requirements are to be followed. These requirements include sensitivity and specificity of techniques, accuracy and precision of research results, stability of reagents' quality in particular conditions of their transportation and storage. The validity of requirements formulated in standards and addressed to manufacturers of medical articles can be proved using reference system, which includes master forms and standard samples, reference techniques and reference laboratories. This approach is supported by data of evaluation of testing systems for measurement of level of thyrotrophic hormone, thyroid hormones and glycated hemoglobin HB A1c. The versions of testing systems can be considered as interchangeable only in case of results corresponding to the results of reference technique and comparable with them. In case of absence of functioning reference system the possibilities of the Joined committee of traceability in laboratory medicine make it possible for manufacturers of reagent sets to apply the certified reference materials under development of manufacturing of sets for large listing of analytes.

  7. A critical comparison of several low Reynolds number k-epsilon turbulence models for flow over a backward facing step

    NASA Technical Reports Server (NTRS)

    Steffen, C. J., Jr.

    1993-01-01

    Turbulent backward-facing step flow was examined using four low turbulent Reynolds number k-epsilon models and one standard high Reynolds number technique. A tunnel configuration of 1:9 (step height: exit tunnel height) was used. The models tested include: the original Jones and Launder; Chien; Launder and Sharma; and the recent Shih and Lumley formulation. The experimental reference of Driver and Seegmiller was used to make detailed comparisons between reattachment length, velocity, pressure, turbulent kinetic energy, Reynolds shear stress, and skin friction predictions. The results indicated that the use of a wall function for the standard k-epsilon technique did not reduce the calculation accuracy for this separated flow when compared to the low turbulent Reynolds number techniques.

  8. 18 CFR 1300.101 - Cross references to employee ethical conduct standards and other applicable regulations.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... employee ethical conduct standards and other applicable regulations. 1300.101 Section 1300.101 Conservation... TENNESSEE VALLEY AUTHORITY § 1300.101 Cross references to employee ethical conduct standards and other...-wide standards of ethical conduct at 5 CFR part 2635 and to the TVA regulations at 5 CFR part 7901...

  9. 18 CFR 1300.101 - Cross references to employee ethical conduct standards and other applicable regulations.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... employee ethical conduct standards and other applicable regulations. 1300.101 Section 1300.101 Conservation... TENNESSEE VALLEY AUTHORITY § 1300.101 Cross references to employee ethical conduct standards and other...-wide standards of ethical conduct at 5 CFR part 2635 and to the TVA regulations at 5 CFR part 7901...

  10. 78 FR 13243 - Updates to Standards Incorporated by Reference; Reapproved ASTM Standards; Technical Amendment

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-27

    ... Characteristics of Plastic Film 2009)[egr]1. and Sheeting. Standard Specification for F682-82a F682-82a 46 56.01-2... (Reapproved Standard Test Method for Determining Gas 2009)[egr]1. Permeability Characteristics of Plastic Film..., Fire prevention, Hazardous substances, Incorporation by reference, Oil pollution, Reporting and...

  11. 18 CFR 1300.101 - Cross references to employee ethical conduct standards and other applicable regulations.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... employee ethical conduct standards and other applicable regulations. 1300.101 Section 1300.101 Conservation... TENNESSEE VALLEY AUTHORITY § 1300.101 Cross references to employee ethical conduct standards and other...-wide standards of ethical conduct at 5 CFR part 2635 and to the TVA regulations at 5 CFR part 7901...

  12. 18 CFR 1300.101 - Cross references to employee ethical conduct standards and other applicable regulations.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... employee ethical conduct standards and other applicable regulations. 1300.101 Section 1300.101 Conservation... TENNESSEE VALLEY AUTHORITY § 1300.101 Cross references to employee ethical conduct standards and other...-wide standards of ethical conduct at 5 CFR part 2635 and to the TVA regulations at 5 CFR part 7901...

  13. 18 CFR 1300.101 - Cross references to employee ethical conduct standards and other applicable regulations.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... employee ethical conduct standards and other applicable regulations. 1300.101 Section 1300.101 Conservation... TENNESSEE VALLEY AUTHORITY § 1300.101 Cross references to employee ethical conduct standards and other...-wide standards of ethical conduct at 5 CFR part 2635 and to the TVA regulations at 5 CFR part 7901...

  14. 36 CFR § 400.1 - Cross-references to employees' ethical conduct standards, financial disclosure regulations and...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...' ethical conduct standards, financial disclosure regulations and other conduct rules. § 400.1 Section Â... RESPONSIBILITIES AND CONDUCT § 400.1 Cross-references to employees' ethical conduct standards, financial disclosure... executive branch-wide standards of ethical conduct and financial disclosure regulations at 5 CFR parts 2634...

  15. Information Object Definition–based Unified Modeling Language Representation of DICOM Structured Reporting

    PubMed Central

    Tirado-Ramos, Alfredo; Hu, Jingkun; Lee, K.P.

    2002-01-01

    Supplement 23 to DICOM (Digital Imaging and Communications for Medicine), Structured Reporting, is a specification that supports a semantically rich representation of image and waveform content, enabling experts to share image and related patient information. DICOM SR supports the representation of textual and coded data linked to images and waveforms. Nevertheless, the medical information technology community needs models that work as bridges between the DICOM relational model and open object-oriented technologies. The authors assert that representations of the DICOM Structured Reporting standard, using object-oriented modeling languages such as the Unified Modeling Language, can provide a high-level reference view of the semantically rich framework of DICOM and its complex structures. They have produced an object-oriented model to represent the DICOM SR standard and have derived XML-exchangeable representations of this model using World Wide Web Consortium specifications. They expect the model to benefit developers and system architects who are interested in developing applications that are compliant with the DICOM SR specification. PMID:11751804

  16. Development, characterization, and validation of an optical transfer standard for ammonia in air

    NASA Astrophysics Data System (ADS)

    Lüttschwager, Nils; Balslev-Harder, David; Leuenberger, Daiana; Pogány, Andrea; Werhahn, Olav; Ebert, Volker

    2017-04-01

    Ammonia is an atmospheric trace gas that is predominantly emitted from anthropogenic agricultural activities. Since elevated levels of ammonia can have negative effects to human health as well as ecosystems, it is imperative to monitor and control ammonia emissions. This requires SI-traceable standards to calibrate ammonia monitoring instrumentation and to make measurements comparable. The lack of such standards became a pressing issue in recent years and the MetNH3 project (www.metnh3.eu) was initiated to fill the gap, pursuing different strategies. The work that we present was part of these endeavours and focusses on the development and application of an optical transfer standard for amount fraction measurements of ammonia in ambient air. An optical transfer standard (OTS) offers an alternative to calibrations of air monitoring instrumentation by means of reference gas mixtures. With an OTS, absolute amount fraction results are derived by evaluating absorption spectra using a spectral model and pre-measured spectral properties of the analyte. In that way, the instrument can measure calibration gas-independent ("calibration-free") and, moreover, can itself serve as standard to calibrate air monitoring analyzers. Molecular spectral properties are the excellent, non-drifting point of reference of the OTS and form, together with traceable measurements of temperature and pressure, the basis for SI-traceable amount fraction measurements. We developed an OTS based on a commercial cavity-ring-down spectrometer with a detection limit below 1 ppb (1 nmol/mol). A custom spectral data evaluation routine for absolute, calibration-free measurements, as well as measurements of spectral properties of ammonia with the focus on measurement uncertainty and traceability [1] are the fundaments of our OTS. Validation measurements were conducted using a SI-traceable ammonia reference gas generator over a period of several months. Here, we present an evaluation of the performance of our OTS from 1 ppb to 200 ppb. We found the results obtained with the OTS to be concordant to reference gas mixtures yielding amount fraction results with standard uncertainties of less than 3 %, for which an uncertainty budget is provided. Acknowledgement: This work was supported by the European Metrology Research Programme (EMRP). The EMRP is jointly funded by the EMRP participating countries within EURAMET and the European Union. References 1. A. Pogány, O. Werhahn, and V. Ebert, High-Accuracy Ammonia Line Intensity Measurements at 1.5 µm, in Imaging and Applied Optics 2016, OSA Technical Digest (online) (Optical Society of America, 2016), paper JT3A.15, DOI: 10.1364/3D.2016.JT3A.15

  17. Performance of a Deep-Learning Neural Network Model in Assessing Skeletal Maturity on Pediatric Hand Radiographs.

    PubMed

    Larson, David B; Chen, Matthew C; Lungren, Matthew P; Halabi, Safwan S; Stence, Nicholas V; Langlotz, Curtis P

    2018-04-01

    Purpose To compare the performance of a deep-learning bone age assessment model based on hand radiographs with that of expert radiologists and that of existing automated models. Materials and Methods The institutional review board approved the study. A total of 14 036 clinical hand radiographs and corresponding reports were obtained from two children's hospitals to train and validate the model. For the first test set, composed of 200 examinations, the mean of bone age estimates from the clinical report and three additional human reviewers was used as the reference standard. Overall model performance was assessed by comparing the root mean square (RMS) and mean absolute difference (MAD) between the model estimates and the reference standard bone ages. Ninety-five percent limits of agreement were calculated in a pairwise fashion for all reviewers and the model. The RMS of a second test set composed of 913 examinations from the publicly available Digital Hand Atlas was compared with published reports of an existing automated model. Results The mean difference between bone age estimates of the model and of the reviewers was 0 years, with a mean RMS and MAD of 0.63 and 0.50 years, respectively. The estimates of the model, the clinical report, and the three reviewers were within the 95% limits of agreement. RMS for the Digital Hand Atlas data set was 0.73 years, compared with 0.61 years of a previously reported model. Conclusion A deep-learning convolutional neural network model can estimate skeletal maturity with accuracy similar to that of an expert radiologist and to that of existing automated models. © RSNA, 2017 An earlier incorrect version of this article appeared online. This article was corrected on January 19, 2018.

  18. The policy effects of feed-in tariff and renewable portfolio standard: A case study of China's waste incineration power industry.

    PubMed

    Xin-Gang, Zhao; Yu-Zhuo, Zhang; Ling-Zhi, Ren; Yi, Zuo; Zhi-Gong, Wu

    2017-10-01

    Among the regulatory policies, feed-in tariffs (FIT) and renewable portfolio standards (RPS) are the most popular to promote the development of renewable energy power industry. They can significantly contribute to the expansion of domestic industrial activities in terms of sustainable energy. This paper uses system dynamics (SD) to establish models of long-term development of China's waste incineration power industry under FIT and RPS schemes, and provides a case study by using scenario analysis method. The model, on the one hand, not only clearly shows the complex logical relationship between the factors but also assesses policy effects of the two policy tools in the development of the industry. On the other hand, it provides a reference for scholars to study similar problems in different countries, thereby facilitating an understanding of waste incineration power's long-term sustainable development pattern under FIT and RPS schemes, and helping to provide references for policy-making institutions. The results show that in the perfect competitive market, the implementation of RPS can promote long-term and rapid development of China's waste incineration power industry given the constraints and actions of the mechanisms of RPS quota proportion, the TGC valid period, and fines, compared with FIT. At the end of the paper, policy implications are offered as references for the government. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. 1 CFR 21.21 - General requirements: References.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 1 General Provisions 1 2010-01-01 2010-01-01 false General requirements: References. 21.21 Section... to test methods or consensus standards produced by a Federal agency that have replaced or preempted private or voluntary test methods or consensus standards in a subject matter area. (5) The reference is to...

  20. NBS/EPA (NATIONAL BUREAU OF STANDARDS/ENVIRONMENTAL PROTECTION AGENCY) CERTIFIED REFERENCE MATERIAL PERFORMANCE AUDIT PROGRAM: STATUS REPORT 1

    EPA Science Inventory

    A traceability procedure has been established which allows specialty gas producers to prepare gaseous pollutant Certified Reference Materials (CRMs). The accuracy, stability and homogeneity of the CRMs approach those of NBS Standard Reference Materials (SRMs). Part of this proced...

  1. NBS/EPA (NATIONAL BUREAU OF STANDARDS/ENVIRONMENTAL PROTECTION AGENCY) CERTIFIED REFERENCE MATERIAL PERFORMANCE AUDIT PROGRAM: STATUS REPORT 2

    EPA Science Inventory

    A traceability procedure has been established which allows specialty gas producers to prepare gaseous pollutant Certified Reference Materials (CRM's). The accuracy, stability and homogeneity of the CRM's approach those of NBS Standard Reference Materials (SRM's). As of October 19...

  2. 39 CFR 111.1 - Mailing Standards of the United States Postal Service, Domestic Mail Manual; incorporated by...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Service, Domestic Mail Manual; incorporated by reference of regulations governing domestic mail services..., Domestic Mail Manual; incorporated by reference of regulations governing domestic mail services. Section... by reference in this part, the Mailing Standards of the United States Postal Service, Domestic Mail...

  3. [Research strategies in standard decoction of medicinal slices].

    PubMed

    Chen, Shi-Lin; Liu, An; Li, Qi; Toru, Sugita; Zhu, Guang-Wei; Sun, Yi; Dai, Yun-Tao; Zhang, Jun; Zhang, Tie-Jun; Takehisa, Tomoda; Liu, Chang-Xiao

    2016-04-01

    This paper discusses the research situation of the standard decoction of medicinal slices at home and abroad. Combined with the experimental data, the author proposes that the standard decoction of medicinal slices is made of single herb using standard process which should be guided by the theory of traditional Chinese medicine, based on clinical practice and referred to modern extraction method with a standard process. And the author also proposes the principles of establishing the specification of process parameters and quality standards and established the basis of drug efficacy material and biological reference. As a standard material and standard system, the standard decoction of medicinal slices can provide standards for clinical medication, standardize the use of the new type of medicinal slices especially for dispensing granules, which were widely used in clinical. It can ensure the accuracy of drugs and consistency of dose, and to solve current supervision difficulties. Moreover the study of standard decoction of medicinal slices will provide the research on dispensing granules, traditional Chinese medicine prescription standard decoction and couplet medicines standard decoction a useful reference. Copyright© by the Chinese Pharmaceutical Association.

  4. 42 CFR 7.2 - Establishment of a user charge.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... DISTRIBUTION OF REFERENCE BIOLOGICAL STANDARDS AND BIOLOGICAL PREPARATIONS § 7.2 Establishment of a user charge... producing and distributing reference biological standards and biological preparations. ...

  5. German translation, cross-cultural adaptation and diagnostic test accuracy of three frailty screening tools : PRISMA-7, FRAIL scale and Groningen Frailty Indicator.

    PubMed

    Braun, Tobias; Grüneberg, Christian; Thiel, Christian

    2018-04-01

    Routine screening for frailty could be used to timely identify older people with increased vulnerability und corresponding medical needs. The aim of this study was the translation and cross-cultural adaptation of the PRISMA-7 questionnaire, the FRAIL scale and the Groningen Frailty Indicator (GFI) into the German language as well as a preliminary analysis of the diagnostic test accuracy of these instruments used to screen for frailty. A diagnostic cross-sectional study was performed. The instrument translation into German followed a standardized process. Prefinal versions were clinically tested on older adults who gave structured in-depth feedback on the scales in order to compile a final revision of the German language scale versions. For the analysis of diagnostic test accuracy (criterion validity), PRISMA-7, FRAIL scale and GFI were considered the index tests. Two reference tests were applied to assess frailty, either based on Fried's model of a Physical Frailty Phenotype or on the model of deficit accumulation, expressed in a Frailty Index. Prefinal versions of the German translations of each instrument were produced and completed by 52 older participants (mean age: 73 ± 6 years). Some minor issues concerning comprehensibility and semantics of the scales were identified and resolved. Using the Physical Frailty Phenotype (frailty prevalence: 4%) criteria as a reference standard, the accuracy of the instruments was excellent (area under the curve AUC >0.90). Taking the Frailty Index (frailty prevalence: 23%) as the reference standard, the accuracy was good (AUC between 0.73 and 0.88). German language versions of PRISMA-7, FRAIL scale and GFI have been established and preliminary results indicate sufficient diagnostic test accuracy that needs to be further established.

  6. Validation of anthropometry and foot-to-foot bioelectrical resistance against a three-component model to assess total body fat in children: the IDEFICS study.

    PubMed

    Bammann, K; Huybrechts, I; Vicente-Rodriguez, G; Easton, C; De Vriendt, T; Marild, S; Mesana, M I; Peeters, M W; Reilly, J J; Sioen, I; Tubic, B; Wawro, N; Wells, J C; Westerterp, K; Pitsiladis, Y; Moreno, L A

    2013-04-01

    To compare different field methods for estimating body fat mass with a reference value derived by a three-component (3C) model in pre-school and school children across Europe. Multicentre validation study. Seventy-eight preschool/school children aged 4-10 years from four different European countries. A standard measurement protocol was carried out in all children by trained field workers. A 3C model was used as the reference method. The field methods included height and weight measurement, circumferences measured at four sites, skinfold measured at two-six sites and foot-to-foot bioelectrical resistance (BIA) via TANITA scales. With the exception of height and neck circumference, all single measurements were able to explain at least 74% of the fat-mass variance in the sample. In combination, circumference models were superior to skinfold models and height-weight models. The best predictions were given by trunk models (combining skinfold and circumference measurements) that explained 91% of the observed fat-mass variance. The optimal data-driven model for our sample includes hip circumference, triceps skinfold and total body mass minus resistance index, and explains 94% of the fat-mass variance with 2.44 kg fat mass limits of agreement. In all investigated models, prediction errors were associated with fat mass, although to a lesser degree in the investigated skinfold models, arm models and the data-driven models. When studying total body fat in childhood populations, anthropometric measurements will give biased estimations as compared to gold standard measurements. Nevertheless, our study shows that when combining circumference and skinfold measurements, estimations of fat mass can be obtained with a limit of agreement of 1.91 kg in normal weight children and of 2.94 kg in overweight or obese children.

  7. Tracking of multiple targets using online learning for reference model adaptation.

    PubMed

    Pernkopf, Franz

    2008-12-01

    Recently, much work has been done in multiple object tracking on the one hand and on reference model adaptation for a single-object tracker on the other side. In this paper, we do both tracking of multiple objects (faces of people) in a meeting scenario and online learning to incrementally update the models of the tracked objects to account for appearance changes during tracking. Additionally, we automatically initialize and terminate tracking of individual objects based on low-level features, i.e., face color, face size, and object movement. Many methods unlike our approach assume that the target region has been initialized by hand in the first frame. For tracking, a particle filter is incorporated to propagate sample distributions over time. We discuss the close relationship between our implemented tracker based on particle filters and genetic algorithms. Numerous experiments on meeting data demonstrate the capabilities of our tracking approach. Additionally, we provide an empirical verification of the reference model learning during tracking of indoor and outdoor scenes which supports a more robust tracking. Therefore, we report the average of the standard deviation of the trajectories over numerous tracking runs depending on the learning rate.

  8. Re-evaluation and extension of the scope of elements in US Geological Survey Standard Reference Water Samples

    USGS Publications Warehouse

    Peart, D.B.; Antweiler, Ronald C.; Taylor, Howard E.; Roth, D.A.; Brinton, T.I.

    1998-01-01

    More than 100 US Geological Survey (USGS) Standard Reference Water Samples (SRWSs) were analyzed for numerous trace constituents, including Al, As, B, Ba, Be, Bi, Br, Cd, Cr, Co, Cu, I, Fe, Pb, Li, Mn, Mo, Ni, Rb, Sb, Se, Sr, Te, Tl, U, V, Zn and major elements (Ca, Mg, Na, SiO2, SO4, Cl) by inductively coupled plasma mass spectrometry and inductively coupled plasma atomic emission spectrometry. In addition, 15 USGS SRWSs and National Institute of Standards and Technology (NIST) standard reference material (SRM) 1641b were analyzed for mercury using cold vapor atomic fluorescence spectrometry. Also USGS SRWS Hg-7 was analyzed using isotope dilution-inductively coupled plasma mass spectrometry. The results were compared with the reported certified values of the following standard reference materials: NIST SRM 1643a, 1643b, 1643c and 1643d and National Research Council of Canada Riverine Water Reference Materials for Trace Metals SLRS-1, SLRS-2 and SLRS-3. New concentration values for trace and major elements in the SRWSs, traceable to the certified standards, are reported. Additional concentration values are reported for elements that were neither previously published for the SRWSs nor traceable to the certified reference materials. Robust statistical procedures were used that were insensitive to outliers. These data can be used for quality assurance/quality control purposes in analytical laboratories.

  9. Establishment of Traceability of Reference Grade Hydrometers at National Physical Laboratory, India (npli)

    NASA Astrophysics Data System (ADS)

    Kumar, Anil; Kumar, Harish; Mandal, Goutam; Das, M. B.; Sharma, D. C.

    The present paper discusses the establishment of traceability of reference grade hydrometers at National Physical Laboratory, India (NPLI). The reference grade hydrometers are calibrated and traceable to the primary solid density standard. The calibration has been done according to standard procedure based on Cuckow's Method and the reference grade hydrometers calibrated covers a wide range. The uncertainty of the reference grade hydrometers has been computed and corrections are also calculated for the scale readings, at which observations are taken.

  10. 40 CFR 792.105 - Test, control, and reference substance characterization.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... or concomitantly according to written standard operating procedures, which provide for periodic...) TOXIC SUBSTANCES CONTROL ACT (CONTINUED) GOOD LABORATORY PRACTICE STANDARDS Test, Control, and Reference...

  11. 40 CFR 792.105 - Test, control, and reference substance characterization.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... or concomitantly according to written standard operating procedures, which provide for periodic...) TOXIC SUBSTANCES CONTROL ACT (CONTINUED) GOOD LABORATORY PRACTICE STANDARDS Test, Control, and Reference...

  12. 40 CFR 792.105 - Test, control, and reference substance characterization.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... or concomitantly according to written standard operating procedures, which provide for periodic...) TOXIC SUBSTANCES CONTROL ACT (CONTINUED) GOOD LABORATORY PRACTICE STANDARDS Test, Control, and Reference...

  13. 40 CFR 792.105 - Test, control, and reference substance characterization.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... or concomitantly according to written standard operating procedures, which provide for periodic...) TOXIC SUBSTANCES CONTROL ACT (CONTINUED) GOOD LABORATORY PRACTICE STANDARDS Test, Control, and Reference...

  14. Data Assimilation - Advances and Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Williams, Brian J.

    2014-07-30

    This presentation provides an overview of data assimilation (model calibration) for complex computer experiments. Calibration refers to the process of probabilistically constraining uncertain physics/engineering model inputs to be consistent with observed experimental data. An initial probability distribution for these parameters is updated using the experimental information. Utilization of surrogate models and empirical adjustment for model form error in code calibration form the basis for the statistical methodology considered. The role of probabilistic code calibration in supporting code validation is discussed. Incorporation of model form uncertainty in rigorous uncertainty quantification (UQ) analyses is also addressed. Design criteria used within a batchmore » sequential design algorithm are introduced for efficiently achieving predictive maturity and improved code calibration. Predictive maturity refers to obtaining stable predictive inference with calibrated computer codes. These approaches allow for augmentation of initial experiment designs for collecting new physical data. A standard framework for data assimilation is presented and techniques for updating the posterior distribution of the state variables based on particle filtering and the ensemble Kalman filter are introduced.« less

  15. Modeling of lead air pollution. [Baton Rouge, Louisiana

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Monteith, C.S.; Henry, J.M.

    1982-05-01

    A study was performed to determine whether vehicular emissions should be included with industrial emissions when demonstrating attainment of the ambient air quality standard for lead. The impact on ambient lead concentrations of the phaseout of leaded gasoline and improved automobile fuel economy was examined by modeling vehicular emissions for 1972 and 1978. Results show that while automobiles in the Baton Rouge area were a significant source of lead in 1972, the phaseout of leaded gasoline and the increase in fuel economy have resulted in a lower contribution (0.20 ..mu..g/m/sup 3/) by automobiles to the ambient lead concentration in 1978.more » The areas having the greatest potential for exceeding the ambient air quality standard can be identified using CDM (EPA's Climatological Dispersion Model). This information can be used to determine the optimal location for an ambient air monitor to demonstrate compliance with the ambient air quality standard. 9 references, 4 figures, 5 tables. (JMT)« less

  16. Reliable landmarks for precise topographical analyses of pathological structural changes of the ovine tibial plateau in 2-D and 3-D subspaces.

    PubMed

    Oláh, Tamás; Reinhard, Jan; Gao, Liang; Goebel, Lars K H; Madry, Henning

    2018-01-08

    Selecting identical topographical locations to analyse pathological structural changes of the osteochondral unit in translational models remains difficult. The specific aim of the study was to provide objectively defined reference points on the ovine tibial plateau based on 2-D sections of micro-CT images useful for reproducible sample harvesting and as standardized landmarks for landmark-based 3-D image registration. We propose 5 reference points, 11 reference lines and 12 subregions that are detectable macroscopically and on 2-D micro-CT sections. Their value was confirmed applying landmark-based rigid and affine 3-D registration methods. Intra- and interobserver comparison showed high reliabilities, and constant positions (standard errors < 1%). Spatial patterns of the thicknesses of the articular cartilage and subchondral bone plate were revealed by measurements in 96 individual points of the tibial plateau. As a case study, pathological phenomena 6 months following OA induction in vivo such as osteophytes and areas of OA development were mapped to the individual subregions. These new reference points and subregions are directly identifiable on tibial plateau specimens or macroscopic images, enabling a precise topographical location of pathological structural changes of the osteochondral unit in both 2-D and 3-D subspaces in a region-appropriate fashion relevant for translational investigations.

  17. 40 CFR 1066.605 - Mass-based and molar-based exhaust emission calculations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... the test interval, corrected to standard temperature and pressure. m PMfil = mass of particulate... = stabilized, ht = hot transient), corrected to standard reference conditions. m PMfil = mass of particulate... stabilized), corrected to standard reference conditions. m PMfil = mass of particulate matter emissions on...

  18. Retrospective Analysis of NIST Standard Reference Material 1450, Fibrous Glass Board, for Thermal Insulation Measurements.

    PubMed

    Zarr, Robert R; Heckert, N Alan; Leigh, Stefan D

    2014-01-01

    Thermal conductivity data acquired previously for the establishment of Standard Reference Material (SRM) 1450, Fibrous Glass Board, as well as subsequent renewals 1450a, 1450b, 1450c, and 1450d, are re-analyzed collectively and as individual data sets. Additional data sets for proto-1450 material lots are also included in the analysis. The data cover 36 years of activity by the National Institute of Standards and Technology (NIST) in developing and providing thermal insulation SRMs, specifically high-density molded fibrous-glass board, to the public. Collectively, the data sets cover two nominal thicknesses of 13 mm and 25 mm, bulk densities from 60 kg·m(-3) to 180 kg·m(-3), and mean temperatures from 100 K to 340 K. The analysis repetitively fits six models to the individual data sets. The most general form of the nested set of multilinear models used is given in the following equation: [Formula: see text]where λ(ρ,T) is the predicted thermal conductivity (W·m(-1)·K(-1)), ρ is the bulk density (kg·m(-3)), T is the mean temperature (K) and ai (for i = 1, 2, … 6) are the regression coefficients. The least squares fit results for each model across all data sets are analyzed using both graphical and analytic techniques. The prevailing generic model for the majority of data sets is the bilinear model in ρ and T. [Formula: see text] One data set supports the inclusion of a cubic temperature term and two data sets with low-temperature data support the inclusion of an exponential term in T to improve the model predictions. Physical interpretations of the model function terms are described. Recommendations for future renewals of SRM 1450 are provided. An Addendum provides historical background on the origin of this SRM and the influence of the SRM on external measurement programs.

  19. Current Status of Herbal Drug Standards in the Indian Pharmacopoeia.

    PubMed

    Prakash, Jai; Srivastava, Sushma; Ray, R S; Singh, Neha; Rajpali, Roshni; Singh, Gyanendra Nath

    2017-12-01

    The benefits of herbal drugs were well understood way back. They have been used for the promotion of health and medical purposes - in disease conditions. It is a conventional belief that herbal drugs have no side effects, are cheaper and locally available. Among Indian systems of medicines, herbs/herbal formulations are used to a larger extent. The quality control of the marketed herbs/herbal formulations is important for acquiring optimum therapeutic benefit as well as for expanding global outreach. Therefore, herbal drug standards are important. Reference standards, the Indian Pharmacopoeia Reference Substances especially the botanical reference substances and the phytochemical reference substances are required for comparison of quality of herbal drugs. The Indian Pharmacopoeia Commission has initiated the process of providing Indian Pharmacopoeia Reference Substances to the stakeholders. Therefore, this article provides an overview of the history and the status of herbal drug standards in the current and forthcoming issues of Indian Pharmacopoeia. In Indian Pharmacopeia, efforts have been made for the harmonization of standards with international counterparts wherever possible. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  20. Advanced Acoustic Model Technical Reference and User Manual

    DTIC Science & Technology

    2010-09-01

    loss (point source). Aatm = ANSI/ ISO atmospheric absorption standard.28 Agrd = Ground reflection and attenuation losses, caused by the ground and the...433.2 1,021.8 25000 788 429.6 1,017.6 26000 754 426.1 1,013.4 27000 722 422.5 1,009.2 28000 691 418.9 1,004.9 29000 660 415.4 1,000.6 30000 631...ANSI/ ISO standard.28 Examples of the weather effects are described here. Consider a situation with winds approximately blowing from NW to SE. Figure 2

  1. A method of camera calibration in the measurement process with reference mark for approaching observation space target

    NASA Astrophysics Data System (ADS)

    Zhang, Hua; Zeng, Luan

    2017-11-01

    Binocular stereoscopic vision can be used for space-based space targets near observation. In order to solve the problem that the traditional binocular vision system cannot work normally after interference, an online calibration method of binocular stereo measuring camera with self-reference is proposed. The method uses an auxiliary optical imaging device to insert the image of the standard reference object into the edge of the main optical path and image with the target on the same focal plane, which is equivalent to a standard reference in the binocular imaging optical system; When the position of the system and the imaging device parameters are disturbed, the image of the standard reference will change accordingly in the imaging plane, and the position of the standard reference object does not change. The camera's external parameters can be re-calibrated by the visual relationship of the standard reference object. The experimental results show that the maximum mean square error of the same object can be reduced from the original 72.88mm to 1.65mm when the right camera is deflected by 0.4 degrees and the left camera is high and low with 0.2° rotation. This method can realize the online calibration of binocular stereoscopic vision measurement system, which can effectively improve the anti - jamming ability of the system.

  2. Update Of The ACR-NEMA Standard Committee

    NASA Astrophysics Data System (ADS)

    Wang, Yen; Best, D. E.; Morse, R. R.; Horii, S. C.; Lehr, J. L.; Lodwick, G. S.; Fuscoe, C.; Nelson, O. L.; Perry, J. R.; Thompson, B. G.; Wessell, W. R.

    1988-06-01

    In January, 1984, the American College of Radiology (ACR) representing the users of imaging equipment and the National Electrical Manufacturers Association (NEMA) representing the manufacturers of imaging equipment joined forces to create a committee that could solve the compatibility issues surrounding the exchange of digital medical images. This committee, the ACR-NEMA Digital Imaging and Communication Standards Committee was composed of radiologists and experts from industry who addressed the problems involved in interfacing different digital imaging modalities. In just two years, the committee and three of its working groups created an industry standard interface, ACR-NEMA Digital Imaging and Communications Standard, Publication No. 300-1985. The ACR-NEMA interface allows digital medical images and related information to be communicated between different imaging devices, regardless of manufacturer or use of differing image formats. The interface is modeled on the International Standards Organization's Open Systems Interconnection sever-layer reference model. It is believed that the development of the Interface was the first step in the development of standards for Medical Picture Archiving and Communications Systems (PACS). Developing the interface Standard has required intensive technical analysis and examination of the future trends for digital imaging in order to design a model which would not be quickly outmoded. To continue the enhancement and future development of image management systems, various working groups have been created under the direction of the ACR-NEMA Committee.

  3. ALT-114 and ALT-118 Alternative Approaches to NIST ...

    EPA Pesticide Factsheets

    In 2016, US EPA approved two separate alternatives (ALT 114 and ALT 118) for the preparation and certification of Hydrogen Chloride (HCl) and Mercury (Hg) cylinder reference gas standards that can serve as EPA Protocol gases where EPA Protocol are required, but unavailable. The alternatives were necessary due to the unavailability of NIST reference materials (SRM, NTRM, CRM or RGM) or VSL reference materials (VSL PRM or VSL CRM), reference materials identified in EPA’s Green Book as necessary to establish the traceability of EPA protocol gases. ALT 114 and ALT 118 provides a pathway for gas vendors to prepare and certify traceable gas cylinder standards for use in certifying Hg and HCl CEMS. In this presentation, EPA will describe the mechanics and requirements of the performance-based approach, provide an update on the availability of these gas standards and also discuss the potential for producing and certifying gas standards for other compounds using this approach. This presentation discusses the importance of NIST-traceable reference gases relative to regulatory source compliance emissions monitoring. Specifically this presentation discusses 2 new approaches for making necessary reference gases available in the absence of NIST reference materials. Moreover, these approaches provide an alternative approach to rapidly make available new reference gases for additional HAPS regulatory compliance emissions measurement and monitoring.

  4. Design and Principles Enabling the Space Reference FOM

    NASA Technical Reports Server (NTRS)

    Moeller, Bjoern; Dexter, Dan; Madden, Michael; Crues, Edwin Z.; Garro, Alfredo; Skuratovskiy, Anton

    2017-01-01

    A first complete draft of the Simulation Interoperability Standards Organization (SISO) Space Reference Federation Object Model (FOM) has now been produced. This paper provides some insights into its capabilities and discusses the opportunity for reuse in other domains. The focus of this first version of the standard is execution control, time management and coordinate systems, well-known reference frames, as well as some basic support for physical entities. The biggest part of the execution control is the coordinated start-up process. This process contains a number of steps, including checking of required federates, handling of early versus late joiners, sharing of federation wide configuration data and multi-phase initialization. An additional part of Execution Control is the coordinated and synchronized transition between Run mode, Freeze mode and Shutdown. For time management, several time lines are defined, including real-time, scenario time, High Level Architecture (HLA) logical time and physical time. A strategy for mixing simulations that use different time steps is introduced, as well as an approach for finding common boundaries for fully synchronized freeze. For describing spatial information, a mechanism with a set of reference frames is specified. Each reference frame has a position and orientation related to a parent reference frame. This makes it possible for federates to perform calculations in reference frames that are convenient to them. An operation on the Moon can be performed using lunar coordinates whereas an operation on Earth can be performed using Earth coordinates. At the same time, coordinates in one reference frame have an unambiguous relationship to a coordinate in another reference frame. While the Space Reference FOM is originally being developed for Space operations, the authors believe that many parts of it can be reused for any simulation that has a focus on physical processes with one or more coordinate systems, and require high fidelity and repeatability.

  5. Hearing the Sound in the Brain: Influences of Different EEG References

    PubMed Central

    Wu, Dan

    2018-01-01

    If the scalp potential signals, the electroencephalogram (EEG), are due to neural “singers” in the brain, how could we listen to them with less distortion? One crucial point is that the data recording on the scalp should be faithful and accurate, thus the choice of reference electrode is a vital factor determining the faithfulness of the data. In this study, music on the scalp derived from data in the brain using three different reference electrodes were compared, including approximate zero reference—reference electrode standardization technique (REST), average reference (AR), and linked mastoids reference (LM). The classic music pieces in waveform format were used as simulated sources inside a head model, and they were forward calculated to scalp as standard potential recordings, i.e., waveform format music from the brain with true zero reference. Then these scalp music was re-referenced into REST, AR, and LM based data, and compared with the original forward data (true zero reference). For real data, the EEG recorded in an orthodontic pain control experiment were utilized for music generation with the three references, and the scale free index (SFI) of these music pieces were compared. The results showed that in the simulation for only one source, different references do not change the music/waveform; for two sources or more, REST provide the most faithful music/waveform to the original ones inside the brain, and the distortions caused by AR and LM were spatial locations of both source and scalp electrode dependent. The brainwave music from the real EEG data showed that REST and AR make the differences of SFI between two states more recognized and found the frontal is the main region that producing the music. In conclusion, REST can reconstruct the true signals approximately, and it can be used to help to listen to the true voice of the neural singers in the brain. PMID:29593487

  6. Standardization in laboratory medicine: Adoption of common reference intervals to the Croatian population.

    PubMed

    Flegar-Meštrić, Zlata; Perkov, Sonja; Radeljak, Andrea

    2016-03-26

    Considering the fact that the results of laboratory tests provide useful information about the state of health of patients, determination of reference value is considered an intrinsic part in the development of laboratory medicine. There are still huge differences in the analytical methods used as well as in the associated reference intervals which could consequently significantly affect the proper assessment of patient health. In a constant effort to increase the quality of patients' care, there are numerous international initiatives for standardization and/or harmonization of laboratory diagnostics in order to achieve maximum comparability of laboratory test results and improve patient safety. Through the standardization and harmonization processes of analytical methods the ability to create unique reference intervals is achieved. Such reference intervals could be applied globally in all laboratories using methods traceable to the same reference measuring system and analysing the biological samples from the populations with similar socio-demographic and ethnic characteristics. In this review we outlined the results of the harmonization processes in Croatia in the field of population based reference intervals for clinically relevant blood and serum constituents which are in accordance with ongoing activity for worldwide standardization and harmonization based on traceability in laboratory medicine.

  7. Standardization in laboratory medicine: Adoption of common reference intervals to the Croatian population

    PubMed Central

    Flegar-Meštrić, Zlata; Perkov, Sonja; Radeljak, Andrea

    2016-01-01

    Considering the fact that the results of laboratory tests provide useful information about the state of health of patients, determination of reference value is considered an intrinsic part in the development of laboratory medicine. There are still huge differences in the analytical methods used as well as in the associated reference intervals which could consequently significantly affect the proper assessment of patient health. In a constant effort to increase the quality of patients’ care, there are numerous international initiatives for standardization and/or harmonization of laboratory diagnostics in order to achieve maximum comparability of laboratory test results and improve patient safety. Through the standardization and harmonization processes of analytical methods the ability to create unique reference intervals is achieved. Such reference intervals could be applied globally in all laboratories using methods traceable to the same reference measuring system and analysing the biological samples from the populations with similar socio-demographic and ethnic characteristics. In this review we outlined the results of the harmonization processes in Croatia in the field of population based reference intervals for clinically relevant blood and serum constituents which are in accordance with ongoing activity for worldwide standardization and harmonization based on traceability in laboratory medicine. PMID:27019800

  8. 15 CFR 200.105 - Standard reference data.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... for application in energy, environment and health, industrial process design, materials durability... Institute of Physics, in the National Standard Reference Data System reports as the NSRDS-NIST series, and...

  9. Ultrasonic angle beam standard reflector. [ultrasonic nondestructive inspection

    NASA Technical Reports Server (NTRS)

    Berry, R. F., Jr. (Inventor)

    1985-01-01

    A method that provides an impression profile in a reference standard material utilized in inspecting critically stressed components with pulsed ultrasound is described. A die stamp having an I letter is used to impress the surface of a reference material. The die stamp is placed against the surface and struck with an inertia imparting member to impress the I in the reference standard material. Upset may appear on the surface as a result of the impression and is removed to form a smooth surface. The stamping and upset removal is repeated until the entire surface area of a depth control platform on the die stamp uniformly contacts the material surface. The I impression profile in the reference standard material is utilized for reflecting pulsed ultrasonic beams for inspection purposes.

  10. A reference architecture for integrated EHR in Colombia.

    PubMed

    de la Cruz, Edgar; Lopez, Diego M; Uribe, Gustavo; Gonzalez, Carolina; Blobel, Bernd

    2011-01-01

    The implementation of national EHR infrastructures has to start by a detailed definition of the overall structure and behavior of the EHR system (system architecture). Architectures have to be open, scalable, flexible, user accepted and user friendly, trustworthy, based on standards including terminologies and ontologies. The GCM provides an architectural framework created with the purpose of analyzing any kind of system, including EHR system´s architectures. The objective of this paper is to propose a reference architecture for the implementation of an integrated EHR in Colombia, based on the current state of system´s architectural models, and EHR standards. The proposed EHR architecture defines a set of services (elements) and their interfaces, to support the exchange of clinical documents, offering an open, scalable, flexible and semantically interoperable infrastructure. The architecture was tested in a pilot tele-consultation project in Colombia, where dental EHR are exchanged.

  11. Representation of the Auroral and Polar Ionosphere in the International Reference Ionosphere (IRI)

    NASA Technical Reports Server (NTRS)

    Bilitza, Dieter; Reinisch, Bodo

    2013-01-01

    This issue of Advances in Space Research presents a selection of papers that document the progress in developing and improving the International Reference Ionosphere (IRI), a widely used standard for the parameters that describe the Earths ionosphere. The core set of papers was presented during the 2010 General Assembly of the Committee on Space Research in Bremen, Germany in a session that focused on the representation of the auroral and polar ionosphere in the IRI model. In addition, papers were solicited and submitted from the scientific community in a general call for appropriate papers.

  12. International longitudinal pediatric reference standards for bone mineral content.

    PubMed

    Baxter-Jones, Adam D G; Burrows, Melonie; Bachrach, Laura K; Lloyd, Tom; Petit, Moira; Macdonald, Heather; Mirwald, Robert L; Bailey, Don; McKay, Heather

    2010-01-01

    To render a diagnosis pediatricians rely upon reference standards for bone mineral density or bone mineral content, which are based on cross-sectional data from a relatively small sample of children. These standards are unable to adequately represent growth in a diverse pediatric population. Thus, the goal of this study was to develop sex and site-specific standards for BMC using longitudinal data collected from four international sites in Canada and the United States. Data from four studies were combined; Saskatchewan Paediatric Bone Mineral Accrual Study (n=251), UBC Healthy Bones Study (n=382); Penn State Young Women's Health Study (n=112) and Stanford's Bone Mineral Accretion study (n=423). Males and females (8 to 25 years) were measured for whole body (WB), total proximal femur (PF), femoral neck (FN) and lumbar spine (LS) BMC (g). Data were analyzed using random effects models. Bland-Altman was used to investigate agreement between predicted and actual data. Age, height, weight and ethnicity independently predicted BMC accrual across sites (P<0.05). Compared to White males, Asian males had 31.8 (6.8) g less WB BMC accrual; Hispanic 75.4 (28.2) g less BMC accrual; Blacks 82.8 (26.3) g more BMC accrual with confounders of age, height and weight controlled. We report similar findings for the PF and FN. Models for females for all sites were similar with age, height and weight as independent significant predictors of BMC accrual (P<0.05). We provide a tool to calculate a child's BMC Z-score, accounting for age, size, sex and ethnicity. In conclusion, when interpreting BMC in pediatrics we recommend standards that are sex, age, size and ethnic specific. Copyright (c) 2009 Elsevier Inc. All rights reserved.

  13. International Longitudinal Paediatric Reference Standards for Bone Mineral Content

    PubMed Central

    Baxter-Jones, Adam DG; McKay, Heather; Burrows, Melonie; Bachrach, Laura K; Lloyd, Tom; Petit, Moira; Macdonald, Heather; Mirwald, Robert L; Bailey, Don

    2014-01-01

    To render a diagnosis pediatricians rely upon reference standards for bone mineral density or bone mineral content, which are based on cross-sectional data from a relatively small sample of children. These standards are unable to adequately represent growth in a diverse pediatric population. Thus, the goal of this study was to develop sex and site specific standards for BMC using longitudinal data collected from four international sites in Canada and the United States. Data from four studies were combined; Saskatchewan Paediatric Bone Mineral Accrual Study (n=251), UBC Healthy Bones Study (n=382); Penn State Young Women’s Health Study (n=112) and Stanford’s Bone Mineral Accretion study (n=423). Males and females (8 to 25 years) were measured for whole body (WB), total proximal femur (PF), femoral neck (FN) and lumbar spine (LS) BMC (g). Data were analyzed using random effects models. Bland-Altman was used to investigate agreement in predicted and actual data. Age, height, weight and ethnicity independently predicted BMC accrual across sites (P <0.05). Compared to White males, Asian males had 31.8 (6.8) g less WB BMC accrual; Hispanic 75.4 (28.2) g less BMC accrual; Blacks 82.8 (26.3) g more BMC accrual with confounders of age, height and weight controlled. Similar findings were found for PF and FN. Female models for all sites were similar with age, height and weight all independent significant predictors of BMC accrual (P <0.05). We provide a tool to calculate a child’s BMC Z-score, accounting for age, size, sex and ethnicity. In conclusion, when interpreting BMC in paediatrics we recommend standards that are sex, age, size and ethnic specific. PMID:19854308

  14. Benefits of a Pharmacology Antimalarial Reference Standard and Proficiency Testing Program Provided by the Worldwide Antimalarial Resistance Network (WWARN)

    PubMed Central

    Lourens, Chris; Lindegardh, Niklas; Barnes, Karen I.; Guerin, Philippe J.; Sibley, Carol H.; White, Nicholas J.

    2014-01-01

    Comprehensive assessment of antimalarial drug resistance should include measurements of antimalarial blood or plasma concentrations in clinical trials and in individual assessments of treatment failure so that true resistance can be differentiated from inadequate drug exposure. Pharmacometric modeling is necessary to assess pharmacokinetic-pharmacodynamic relationships in different populations to optimize dosing. To accomplish both effectively and to allow comparison of data from different laboratories, it is essential that drug concentration measurement is accurate. Proficiency testing (PT) of laboratory procedures is necessary for verification of assay results. Within the Worldwide Antimalarial Resistance Network (WWARN), the goal of the quality assurance/quality control (QA/QC) program is to facilitate and sustain high-quality antimalarial assays. The QA/QC program consists of an international PT program for pharmacology laboratories and a reference material (RM) program for the provision of antimalarial drug standards, metabolites, and internal standards for laboratory use. The RM program currently distributes accurately weighed quantities of antimalarial drug standards, metabolites, and internal standards to 44 pharmacology, in vitro, and drug quality testing laboratories. The pharmacology PT program has sent samples to eight laboratories in four rounds of testing. WWARN technical experts have provided advice for correcting identified problems to improve performance of subsequent analysis and ultimately improved the quality of data. Many participants have demonstrated substantial improvements over subsequent rounds of PT. The WWARN QA/QC program has improved the quality and value of antimalarial drug measurement in laboratories globally. It is a model that has potential to be applied to strengthening laboratories more widely and improving the therapeutics of other infectious diseases. PMID:24777099

  15. 40 CFR 89.6 - Reference materials.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... set forth the material that has been incorporated by reference in this part. (1) ASTM material. The... 19428-2959. Document number and name 40 CFR part 89 reference ASTM D86-97: “Standard Test Method for Distillation of Petroleum Products at Atmospheric Pressure” Appendix A to Subpart D. ASTM D93-97: “Standard...

  16. 22 CFR 1100.1 - Cross-references to employee ethical conduct standards, financial disclosure and financial...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 22 Foreign Relations 2 2011-04-01 2009-04-01 true Cross-references to employee ethical conduct... STATES SECTION EMPLOYEE RESPONSIBILITIES AND CONDUCT § 1100.1 Cross-references to employee ethical... executive branch standards of ethical conduct contained in 5 CFR part 2635, the executive branch financial...

  17. 12 CFR 1401.1 - Cross-references to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 12 Banks and Banking 7 2011-01-01 2011-01-01 false Cross-references to employee ethical conduct... INSURANCE CORPORATION EMPLOYEE RESPONSIBILITIES AND CONDUCT § 1401.1 Cross-references to employee ethical... the Farm Credit System Insurance Corporation are subject to the Standards of Ethical Conduct for...

  18. 22 CFR 1100.1 - Cross-references to employee ethical conduct standards, financial disclosure and financial...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 22 Foreign Relations 2 2010-04-01 2010-04-01 true Cross-references to employee ethical conduct... STATES SECTION EMPLOYEE RESPONSIBILITIES AND CONDUCT § 1100.1 Cross-references to employee ethical... executive branch standards of ethical conduct contained in 5 CFR part 2635, the executive branch financial...

  19. 12 CFR 1401.1 - Cross-references to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 7 2010-01-01 2010-01-01 false Cross-references to employee ethical conduct... INSURANCE CORPORATION EMPLOYEE RESPONSIBILITIES AND CONDUCT § 1401.1 Cross-references to employee ethical... the Farm Credit System Insurance Corporation are subject to the Standards of Ethical Conduct for...

  20. 12 CFR 1401.1 - Cross-references to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 12 Banks and Banking 9 2013-01-01 2013-01-01 false Cross-references to employee ethical conduct... INSURANCE CORPORATION EMPLOYEE RESPONSIBILITIES AND CONDUCT § 1401.1 Cross-references to employee ethical... the Farm Credit System Insurance Corporation are subject to the Standards of Ethical Conduct for...

  1. 22 CFR 1100.1 - Cross-references to employee ethical conduct standards, financial disclosure and financial...

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 22 Foreign Relations 2 2013-04-01 2009-04-01 true Cross-references to employee ethical conduct... STATES SECTION EMPLOYEE RESPONSIBILITIES AND CONDUCT § 1100.1 Cross-references to employee ethical... executive branch standards of ethical conduct contained in 5 CFR part 2635, the executive branch financial...

  2. 12 CFR 1401.1 - Cross-references to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 12 Banks and Banking 9 2012-01-01 2012-01-01 false Cross-references to employee ethical conduct... INSURANCE CORPORATION EMPLOYEE RESPONSIBILITIES AND CONDUCT § 1401.1 Cross-references to employee ethical... the Farm Credit System Insurance Corporation are subject to the Standards of Ethical Conduct for...

  3. 12 CFR 1401.1 - Cross-references to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 12 Banks and Banking 10 2014-01-01 2014-01-01 false Cross-references to employee ethical conduct... INSURANCE CORPORATION EMPLOYEE RESPONSIBILITIES AND CONDUCT § 1401.1 Cross-references to employee ethical... the Farm Credit System Insurance Corporation are subject to the Standards of Ethical Conduct for...

  4. Sensitivity tests to define the source apportionment performance criteria in the DeltaSA tool

    NASA Astrophysics Data System (ADS)

    Pernigotti, Denise; Belis, Claudio A.

    2017-04-01

    Identification and quantification of the contribution of emission sources to a given area is a key task for the design of abatement strategies. Moreover, European member states are obliged to report this kind of information for zones where the pollution levels exceed the limit values. At present, little is known about the performance and uncertainty of the variety of methodologies used for source apportionment and the comparability between the results of studies using different approaches. The source apportionment Delta (SA Delta) is a tool developed by the EC-JRC to support the particulate matter source apportionment modellers in the identification of sources (for factor analysis studies) and/or in the measure of their performance. The source identification is performed by the tool measuring the proximity of any user chemical profile to preloaded repository data (SPECIATE and SPECIEUROPE). The model performances criteria are based on standard statistical indexes calculated by comparing participants' source contribute estimates and their time series with preloaded references data. Those preloaded data refer to previous European SA intercomparison exercises: the first with real world data (22 participants), the second with synthetic data (25 participants) and the last with real world data which was also extended to Chemical Transport Models (38 receptor models and 4 CTMs). The references used for the model performances are 'true' (predefined by JRC) for the synthetic while they are calculated as ensemble average of the participants' results in real world intercomparisons. The candidates used for each source ensemble reference calculation were selected among participants results based on a number of consistency checks plus the similarity between their chemical profiles to the repository measured data. The estimation of the ensemble reference uncertainty is crucial in order to evaluate the users' performances against it. For this reason a sensitivity analysis on different methods to estimate the ensemble references' uncertainties was performed re-analyzing the synthetic intercomparison dataset, the only one where 'true' reference and ensemble reference contributions were both present. The Delta SA is now available on-line and will be presented, with a critical discussion of the sensitivity analysis on the ensemble reference uncertainty. In particular the grade of among participants mutual agreement on the presence of a certain source should be taken into account. Moreover also the importance of the synthetic intercomparisons in order to catch receptor models common biases will be stressed.

  5. A PROCEDURE FOR ESTABLISHING TRACEABILITY OF GAS MIXTURES TO CERTAIN NATIONAL BUREAU OF STANDARDS STANDARD REFERENCE MATERIALS

    EPA Science Inventory

    This procedure includes the specifications and requirements that must be followed by gas manufacturers during the preparation of compressed cylinder gas Certified Reference Materials (CRM). A CRM is a certified gas standard prepared at a concentration that does not exceed + or - ...

  6. 75 FR 51177 - Safety Standard for Infant Bath Seats; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-19

    ... a standard for infant bath seats by incorporating by reference ASTM F 1967-08a with certain changes... incorporating by reference ASTM F 1967-08. An introductory phrase in the stability performance requirements in the ASTM standard should have been removed to make the provision consistent with the Commission's...

  7. Modeling Non-Linear Material Properties in Composite Materials

    DTIC Science & Technology

    2016-06-28

    2 Figure 2: Implementation of multiscale enrichment into FEA ...corresponding to the mth degree of freedom, and is the associated degree of freedom. For FEA , the standard shape function, NI, which can be...varies depending on the governing method. In this presentation we will focus in the FEA approach. Reference [4] gives complete details on the

  8. Incubating Innovation: A standard model for nurturing new businesses, the incubator gains prominence in the world of biotech.

    PubMed

    Grifantini, Kristina

    2015-01-01

    Incubators, accelerators, innovation centers, launch pads. Everyone defines the idea a bit differently, but, generally, these infrastructures refer to a subsidized space where fledgling companies get support?a combination of mentorship, funding, low rent, networking opportunities, and other training?with the goal of propelling early businesses to success.

  9. Architectural and Functional Design and Evaluation of E-Learning VUIS Based on the Proposed IEEE LTSA Reference Model.

    ERIC Educational Resources Information Center

    O'Droma, Mairtin S.; Ganchev, Ivan; McDonnell, Fergal

    2003-01-01

    Presents a comparative analysis from the Institute of Electrical and Electronics Engineers (IEEE) Learning Technology Standards Committee's (LTSC) of the architectural and functional design of e-learning delivery platforms and applications, e-learning course authoring tools, and learning management systems (LMSs), with a view of assessing how…

  10. Meta-Analysis of Free-Response Studies, 1992-2008: Assessing the Noise Reduction Model in Parapsychology

    ERIC Educational Resources Information Center

    Storm, Lance; Tressoldi, Patrizio E.; Di Risio, Lorenzo

    2010-01-01

    We report the results of meta-analyses on 3 types of free-response study: (a) ganzfeld (a technique that enhances a communication anomaly referred to as "psi"); (b) nonganzfeld noise reduction using alleged psi-enhancing techniques such as dream psi, meditation, relaxation, or hypnosis; and (c) standard free response (nonganzfeld, no noise…

  11. 10 CFR 431.95 - Materials incorporated by reference.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... reference. (1) Air-Conditioning and Refrigeration Institute (ARI) Standard 210/240-2003 published in 2003... standards from the Air-Conditioning and Refrigeration Institute, 4301 North Fairfax Drive, Suite 425...

  12. 46 CFR 160.151-5 - Incorporation by reference.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... reference in this subpart and the sections affected are as follows: American Society for Testing and... of Standards and Technology (formerly National Bureau of Standards) c/o National Technical...

  13. 46 CFR 160.151-5 - Incorporation by reference.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... reference in this subpart and the sections affected are as follows: American Society for Testing and... of Standards and Technology (formerly National Bureau of Standards) c/o National Technical...

  14. Acoustic Model of the Remnant Bubble Cloud from Underwater Explosion

    DTIC Science & Technology

    2012-11-01

    fluid, bu g is the acceleration due to gravity, and C is the drag coefficient. Here we use the Grace Drag model (Clift et al., 1978; ANSYS CFX ...Dynaflow, Inc., Baltimore, MD for providing the bubble maker data. REFERENCES ANSYS CFX -Solver, Release 13.0: Theory 2010. ANSYS Inc. Brennen...unclassified Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 21-23 November 2012, Fremantle, Australia Proceedings of Acoustics 2012

  15. Blind image quality assessment without training on human opinion scores

    NASA Astrophysics Data System (ADS)

    Mittal, Anish; Soundararajan, Rajiv; Muralidhar, Gautam S.; Bovik, Alan C.; Ghosh, Joydeep

    2013-03-01

    We propose a family of image quality assessment (IQA) models based on natural scene statistics (NSS), that can predict the subjective quality of a distorted image without reference to a corresponding distortionless image, and without any training results on human opinion scores of distorted images. These `completely blind' models compete well with standard non-blind image quality indices in terms of subjective predictive performance when tested on the large publicly available `LIVE' Image Quality database.

  16. Certification of elements in and use of standard reference material 3280 multivitamin/multielement tablets.

    PubMed

    Turk, Gregory C; Sharpless, Katherine E; Cleveland, Danielle; Jongsma, Candice; Mackey, Elizabeth A; Marlow, Anthony F; Oflaz, Rabia; Paul, Rick L; Sieber, John R; Thompson, Robert Q; Wood, Laura J; Yu, Lee L; Zeisler, Rolf; Wise, Stephen A; Yen, James H; Christopher, Steven J; Day, Russell D; Long, Stephen E; Greene, Ella; Harnly, James; Ho, I-Pin; Betz, Joseph M

    2013-01-01

    Standard Reference Material 3280 Multivitamin/ Multielement Tablets was issued by the National Institute of Standards and Technology in 2009, and has certified and reference mass fraction values for 13 vitamins, 26 elements, and two carotenoids. Elements were measured using two or more analytical methods at NIST with additional data contributed by collaborating laboratories. This reference material is expected to serve a dual purpose: to provide quality assurance in support of a database of dietary supplement products and to provide a means for analysts, dietary supplement manufacturers, and researchers to assess the appropriateness and validity of their analytical methods and the accuracy of their results.

  17. Archetype-based semantic integration and standardization of clinical data.

    PubMed

    Moner, David; Maldonado, Jose A; Bosca, Diego; Fernandez, Jesualdo T; Angulo, Carlos; Crespo, Pere; Vivancos, Pedro J; Robles, Montserrat

    2006-01-01

    One of the basic needs for any healthcare professional is to be able to access to clinical information of patients in an understandable and normalized way. The lifelong clinical information of any person supported by electronic means configures his/her Electronic Health Record (EHR). This information is usually distributed among several independent and heterogeneous systems that may be syntactically or semantically incompatible. The Dual Model architecture has appeared as a new proposal for maintaining a homogeneous representation of the EHR with a clear separation between information and knowledge. Information is represented by a Reference Model which describes common data structures with minimal semantics. Knowledge is specified by archetypes, which are formal representations of clinical concepts built upon a particular Reference Model. This kind of architecture is originally thought for implantation of new clinical information systems, but archetypes can be also used for integrating data of existing and not normalized systems, adding at the same time a semantic meaning to the integrated data. In this paper we explain the possible use of a Dual Model approach for semantic integration and standardization of heterogeneous clinical data sources and present LinkEHR-Ed, a tool for developing archetypes as elements for integration purposes. LinkEHR-Ed has been designed to be easily used by the two main participants of the creation process of archetypes for clinical data integration: the Health domain expert and the Information Technologies domain expert.

  18. Noninvasive Classification of Hepatic Fibrosis Based on Texture Parameters From Double Contrast-Enhanced Magnetic Resonance Images

    PubMed Central

    Bahl, Gautam; Cruite, Irene; Wolfson, Tanya; Gamst, Anthony C.; Collins, Julie M.; Chavez, Alyssa D.; Barakat, Fatma; Hassanein, Tarek; Sirlin, Claude B.

    2016-01-01

    Purpose To demonstrate a proof of concept that quantitative texture feature analysis of double contrast-enhanced magnetic resonance imaging (MRI) can classify fibrosis noninvasively, using histology as a reference standard. Materials and Methods A Health Insurance Portability and Accountability Act (HIPAA)-compliant Institutional Review Board (IRB)-approved retrospective study of 68 patients with diffuse liver disease was performed at a tertiary liver center. All patients underwent double contrast-enhanced MRI, with histopathology-based staging of fibrosis obtained within 12 months of imaging. The MaZda software program was used to compute 279 texture parameters for each image. A statistical regularization technique, generalized linear model (GLM)-path, was used to develop a model based on texture features for dichotomous classification of fibrosis category (F ≤2 vs. F ≥3) of the 68 patients, with histology as the reference standard. The model's performance was assessed and cross-validated. There was no additional validation performed on an independent cohort. Results Cross-validated sensitivity, specificity, and total accuracy of the texture feature model in classifying fibrosis were 91.9%, 83.9%, and 88.2%, respectively. Conclusion This study shows proof of concept that accurate, noninvasive classification of liver fibrosis is possible by applying quantitative texture analysis to double contrast-enhanced MRI. Further studies are needed in independent cohorts of subjects. PMID:22851409

  19. Evaluation of the INTERGROWTH-21st project newborn standard for use in Canada.

    PubMed

    Liu, Shiliang; Metcalfe, Amy; León, Juan Andrés; Sauve, Reg; Kramer, Michael S; Joseph, K S

    2017-01-01

    To evaluate the performance of the INTERGROWTH-21st Project newborn standard vis-a-vis the current Canadian birth weight-for-gestational age reference. All hospital-based singleton live births in Canada (excluding Quebec) between 2002 and 2012 with a gestational age between 33 and 42 weeks were included using information obtained from the Canadian Institute for Health Information. Small- and large-for gestational age centile categories of the INTERGROWTH standard and Canadian reference were contrasted in terms of frequency distributions and rates of composite neonatal morbidity/mortality. Among 2,753,817 singleton live births, 0.87% and 9.63% were <3rd centile and >97th centile, respectively, of the INTERGROWTH standard, while 2.27% and 3.55% were <3rd centile and >97th centile, respectively, of the Canadian reference. Infants <3rd centile and >97th centile had a composite neonatal morbidity/mortality rate of 46.4 and 12.9 per 1,000 live births, respectively, under the INTERGROWTH standard and 30.9 and 16.6 per 1,000 live births, respectively, under the Canadian reference. The INTERGROWTH standard <3rd centile and >97th centile categories had detection rates of 3.14% and 9.74%, respectively, for composite neonatal morbidity/ mortality compared with 5.48% and 4.60%, respectively for the Canadian reference. Similar patterns were evident in high- and low-risk subpopulations. The centile distribution of the INTERGROWTH newborn standard is left shifted compared with the Canadian reference, and this shift alters the frequencies and neonatal morbidity/mortality rates associated with specific centile categories. Further outcome-based research is required for defining abnormal growth categories before the INTERGROWTH newborn standard can be used.

  20. A Reference Model for Monitoring IoT WSN-Based Applications.

    PubMed

    Capella, Juan Vicente; Campelo, José Carlos; Bonastre, Alberto; Ors, Rafael

    2016-10-30

    The Internet of Things (IoT) is, at this moment, one of the most promising technologies that has arisen for decades. Wireless Sensor Networks (WSNs) are one of the main pillars for many IoT applications, insofar as they require to obtain context-awareness information. The bibliography shows many difficulties in their real implementation that have prevented its massive deployment. Additionally, in IoT environments where data producers and data consumers are not directly related, compatibility and certification issues become fundamental. Both problems would profit from accurate knowledge of the internal behavior of WSNs that must be obtained by the utilization of appropriate tools. There are many ad-hoc proposals with no common structure or methodology, and intended to monitor a particular WSN. To overcome this problem, this paper proposes a structured three-layer reference model for WSN Monitoring Platforms (WSN-MP), which offers a standard environment for the design of new monitoring platforms to debug, verify and certify a WSN's behavior and performance, and applicable to every WSN. This model also allows the comparative analysis of the current proposals for monitoring the operation of WSNs. Following this methodology, it is possible to achieve a standardization of WSN-MP, promoting new research areas in order to solve the problems of each layer.

Top