Sample records for standard reference serum

  1. Baseline Assessment of 25-Hydroxyvitamin D Reference Material and Proficiency Testing/External Quality Assurance Material Commutability: A Vitamin D Standardization Program Study.

    PubMed

    Phinney, Karen W; Sempos, Christopher T; Tai, Susan S-C; Camara, Johanna E; Wise, Stephen A; Eckfeldt, John H; Hoofnagle, Andrew N; Carter, Graham D; Jones, Julia; Myers, Gary L; Durazo-Arvizu, Ramon; Miller, W Greg; Bachmann, Lorin M; Young, Ian S; Pettit, Juanita; Caldwell, Grahame; Liu, Andrew; Brooks, Stephen P J; Sarafin, Kurtis; Thamm, Michael; Mensink, Gert B M; Busch, Markus; Rabenberg, Martina; Cashman, Kevin D; Kiely, Mairead; Galvin, Karen; Zhang, Joy Y; Kinsella, Michael; Oh, Kyungwon; Lee, Sun-Wha; Jung, Chae L; Cox, Lorna; Goldberg, Gail; Guberg, Kate; Meadows, Sarah; Prentice, Ann; Tian, Lu; Brannon, Patsy M; Lucas, Robyn M; Crump, Peter M; Cavalier, Etienne; Merkel, Joyce; Betz, Joseph M

    2017-09-01

    The Vitamin D Standardization Program (VDSP) coordinated a study in 2012 to assess the commutability of reference materials and proficiency testing/external quality assurance materials for total 25-hydroxyvitamin D [25(OH)D] in human serum, the primary indicator of vitamin D status. A set of 50 single-donor serum samples as well as 17 reference and proficiency testing/external quality assessment materials were analyzed by participating laboratories that used either immunoassay or LC-MS methods for total 25(OH)D. The commutability test materials included National Institute of Standards and Technology Standard Reference Material 972a Vitamin D Metabolites in Human Serum as well as materials from the College of American Pathologists and the Vitamin D External Quality Assessment Scheme. Study protocols and data analysis procedures were in accordance with Clinical and Laboratory Standards Institute guidelines. The majority of the test materials were found to be commutable with the methods used in this commutability study. These results provide guidance for laboratories needing to choose appropriate reference materials and select proficiency or external quality assessment programs and will serve as a foundation for additional VDSP studies.

  2. A candidate reference method for serum potassium measurement by inductively coupled plasma mass spectrometry.

    PubMed

    Yan, Ying; Han, Bingqing; Zeng, Jie; Zhou, Weiyan; Zhang, Tianjiao; Zhang, Jiangtao; Chen, Wenxiang; Zhang, Chuanbao

    2017-08-28

    Potassium is an important serum ion that is frequently assayed in clinical laboratories. Quality assurance requires reference methods; thus, the establishment of a candidate reference method for serum potassium measurements is important. An inductively coupled plasma mass spectrometry (ICP-MS) method was developed. Serum samples were gravimetrically spiked with an aluminum internal standard, digested with 69% ultrapure nitric acid, and diluted to the required concentration. The 39K/27Al ratios were measured by ICP-MS in hydrogen mode. The method was calibrated using 5% nitric acid matrix calibrators, and the calibration function was established using the bracketing method. The correlation coefficients between the measured 39K/27Al ratios and the analyte concentration ratios were >0.9999. The coefficients of variation were 0.40%, 0.68%, and 0.22% for the three serum samples, and the analytical recovery was 99.8%. The accuracy of the measurement was also verified by measuring certified reference materials, SRM909b and SRM956b. Comparison with the ion selective electrode routine method and international inter-laboratory comparisons gave satisfied results. The new ICP-MS method is specific, precise, simple, and low-cost, and it may be used as a candidate reference method for standardizing serum potassium measurements.

  3. Certified reference materials (GBW09170 and 09171) of creatinine in human serum.

    PubMed

    Dai, Xinhua; Fang, Xiang; Shao, Mingwu; Li, Ming; Huang, Zejian; Li, Hongmei; Jiang, You; Song, Dewei; He, Yajuan

    2011-02-15

    Creatinine is the most widely used clinical marker for assessing renal function. Concentrations of creatinine in human serum need to be carefully checked in order to ensure accurate diagnosis of renal function. Therefore, development of certified reference materials (CRMs) of creatinine in serum is of increasing importance. In this study, two new CRMs (Nos. GBW09170 and 09171) for creatinine in human serum have been developed. They were prepared with mixtures of several dozens of healthy people's and kidney disease patient's serum, respectively. The certified values of 8.10, 34.1 mg/kg for these two CRMs have been assigned by liquid chromatography-isotope dilution mass spectrometry (LC-IDMS) method which was validated by using standard reference material (SRM) of SRM909b (a reference material obtained from National Institute of Standards and Technology, NIST). The expanded uncertainties of certified values for low and high concentrations were estimated to be 1.2 and 1.1%, respectively. The certified values were further confirmed by an international intercomparison for the determination of creatinine in human serum (Consultative Committee for Amount of Substance, CCQM) of K80 (CCQM-K80). These new CRMs of creatinine in human serum pool are totally native without additional creatinine spiked for enrichment. These new CRMs are capable of validating routine clinical methods for ensuring accuracy, reliability and comparability of analytical results from different clinical laboratories. They can also be used for instrument validation, development of secondary reference materials, and evaluating the accuracy of high order clinical methods for the determination of creatinine in human serum. Copyright © 2011 Elsevier B.V. All rights reserved.

  4. Differences in serum thyroglobulin measurements by 3 commercial immunoradiometric assay kits and laboratory standardization using Certified Reference Material 457 (CRM-457).

    PubMed

    Lee, Ji In; Kim, Ji Young; Choi, Joon Young; Kim, Hee Kyung; Jang, Hye Won; Hur, Kyu Yeon; Kim, Jae Hyeon; Kim, Kwang-Won; Chung, Jae Hoon; Kim, Sun Wook

    2010-09-01

    Serum thyroglobulin (Tg) is essential in the follow-up of patients with differentiated thyroid carcinoma (DTC). However, interchangeability and standardization between Tg assays have not yet been achieved, even with the development of an international Tg standard (Certified Reference Material 457 [CRM-457]). Serum Tg from 30 DTC patients and serially diluted CRM-457 were measured using 3 different immunoradiometric assays (IRMA-1, IRMA-2, IRMA-3). The intraclass correlation coefficient (ICC) method was used to describe the concordance of each IRMA to CRM-457. The serum Tg measured by 3 different IRMAs correlated well (r > .85, p < .0001), but clinically relevant discrepancies were found in 13.3% of patients. IRMA-3, which claims to be standardized to CRM-457, showed the best ICC (p(1) = .98) for the CRM-457. Hospitals caring for patients with DTC should either set their own cutoffs for IRMAs for Tg based on their patient pools, or adopt IRMAs standardized to CRM-457 and calibrate their laboratory using CRM-457.

  5. Determination of perfluorinated alkyl acid concentrations in human serum and milk standard reference materials.

    PubMed

    Keller, Jennifer M; Calafat, Antonia M; Kato, Kayoko; Ellefson, Mark E; Reagen, William K; Strynar, Mark; O'Connell, Steven; Butt, Craig M; Mabury, Scott A; Small, Jeff; Muir, Derek C G; Leigh, Stefan D; Schantz, Michele M

    2010-05-01

    Standard Reference Materials (SRMs) are certified reference materials produced by the National Institute of Standards and Technology that are homogeneous materials well characterized with values for specified properties, such as environmental contaminant concentrations. They can be used to validate measurement methods and are critical in improving data quality. Disagreements in perfluorinated alkyl acid (PFAA) concentrations measured in environmental matrices during past interlaboratory comparisons emphasized the need for SRMs with values assigned for PFAAs. We performed a new interlaboratory comparison among six laboratories and provided, for the first time, value assignment of PFAAs in SRMs. Concentrations for perfluorooctane sulfonate (PFOS), perfluorooctanoate (PFOA), and other PFAAs in two human serum and two human milk SRMs are reported. PFAA concentration measurements agreed for serum SRM 1957 using different analytical methods in six laboratories and for milk SRM 1954 in three laboratories. The interlaboratory relative standard deviation for PFOS in SRM 1957 was 7%, which is an improvement over past interlaboratory studies. Matrix interferences are discussed, as well as temporal trends and the percentage of branched vs. linear isomers. The concentrations in these SRMs are similar to the present-day average concentrations measured in human serum and milk, resulting in representative and useful control materials for PFAA human monitoring studies.

  6. Modifications to the NIST reference measurement procedure (RMP) for the determination of serum glucose by isotope dilution gas chromatography/mass spectrometry.

    PubMed

    Prendergast, Jocelyn L; Sniegoski, Lorna T; Welch, Michael J; Phinney, Karen W

    2010-07-01

    The definitive method (DM), now known as the reference measurement procedure (RMP), for the analysis of glucose in serum was originally published in 1982 by the National Institute of Standards and Technology (NIST). Over the years the method has been subject to a number of modifications to adapt to newer technologies and simplify sample preparation. We discuss here an adaptation of the method associated with serum glucose measurements using a modified isotope dilution gas chromatography/mass spectrometry (ID-GC/MS) method. NIST has used this modified method to certify the concentrations of glucose in SRM 965b, Glucose in Frozen Human Serum, and SRM 1950, Metabolites in Human Plasma. Comparison of results from the revised method with certified values for existing Standard Reference Materials (SRMs) demonstrated that these modifications have not affected the quality of the measurements, giving both good precision and accuracy, while reducing the sample preparation time by a day and a half.

  7. Age and sex variation in serum albumin concentration: an observational study.

    PubMed

    Weaving, Gary; Batstone, Gifford F; Jones, Richard G

    2016-01-01

    In the UK, a common reference interval for serum albumin is widely used irrespective of age or sex. Implicit in this is that laboratories produce analytically similar results. This paper challenges the validity of this approach. A three-week collection of results sent to all primary care centres in England has been analysed by age, sex and laboratory. In all, 1,079,193 serum albumin reports were included in this analysis. The mean population serum albumin concentration increases to peak at around age 20 years and then decreases with increasing age. Values in females decrease more rapidly but become close to male values at 60 years. The variation between laboratories was large and potentially clinically significant. Reference intervals for serum albumin should be stratified by age and sex. Until there is greater methodological standardization, laboratories should determine their own reference intervals and not accept a single consensus reference interval. © The Author(s) 2015.

  8. [Preparation and characterization of follwing the national standard anti-Brucella abortus serum, bovine].

    PubMed

    Li, Cui; Guan, Fushi; Dai, Zhihong; Jiang, Hui; Wen, Fang; Lu, Lianshou; Wang, Zaishi

    2011-05-01

    To prepare anti-Brucella abortus serum used for calibrate the agglutination test follwing the national standard, 4 anti-Brucella abortus sera were obtained from 4 cows infected with Brucella abortus naturally. By potency testing, the third serum was selected. Sterility, vaccum degree, residual moisture, uniformity and stability of this standard material were tested and proved to meet the national standard. Referring to the international standard, RBT (Rose-Bengal plate agglutination test), SAT (standard tube agglutination) and CFT (complement fixation test) titers of this standard material were measured to be 1:160 "+" 1:2 400 "++" and 1:800 "++", which are identical with the collaborative assay results. International unit of the standard material is 4 000 IU/mL.

  9. The establishment of a WHO Reference Reagent for anti-malaria (Plasmodium falciparum) human serum.

    PubMed

    Bryan, Donna; Silva, Nilupa; Rigsby, Peter; Dougall, Thomas; Corran, Patrick; Bowyer, Paul W; Ho, Mei Mei

    2017-08-05

    At a World Health Organization (WHO) sponsored meeting it was concluded that there is an urgent need for a reference preparation that contains antibodies against malaria antigens in order to support serology studies and vaccine development. It was proposed that this reference would take the form of a lyophilized serum or plasma pool from a malaria-endemic area. In response, an immunoassay standard, comprising defibrinated human plasma has been prepared and evaluated in a collaborative study. A pool of human plasma from a malaria endemic region was collected from 140 single plasma donations selected for reactivity to Plasmodium falciparum apical membrane antigen-1 (AMA-1) and merozoite surface proteins (MSP-1 19 , MSP-1 42 , MSP-2 and MSP-3). This pool was defibrinated, filled and freeze dried into a single batch of ampoules to yield a stable source of naturally occurring antibodies to P. falciparum. The preparation was evaluated by an enzyme-linked immunosorbent assay (ELISA) in a collaborative study with sixteen participants from twelve different countries. This anti-malaria human serum preparation (NIBSC Code: 10/198) was adopted by the WHO Expert Committee on Biological Standardization (ECBS) in October 2014, as the first WHO reference reagent for anti-malaria (Plasmodium falciparum) human serum with an assigned arbitrary unitage of 100 units (U) per ampoule. Analysis of the reference reagent in a collaborative study has demonstrated the benefit of this preparation for the reduction in inter- and intra-laboratory variability in ELISA. Whilst locally sourced pools are regularly use for harmonization both within and between a few laboratories, the presence of a WHO-endorsed reference reagent should enable optimal harmonization of malaria serological assays either by direct use of the reference reagent or calibration of local standards against this WHO reference. The intended uses of this reference reagent, a multivalent preparation, are (1) to allow cross-comparisons of results of vaccine trials performed in different centres/with different products; (2) to facilitate standardization and harmonization of immunological assays used in epidemiology research; and (3) to allow optimization and validation of immunological assays used in malaria vaccine development.

  10. Reference measurement procedure for total glycerides by isotope dilution GC-MS.

    PubMed

    Edwards, Selvin H; Stribling, Shelton L; Pyatt, Susan D; Kimberly, Mary M

    2012-04-01

    The CDC's Lipid Standardization Program established the chromotropic acid (CA) reference measurement procedure (RMP) as the accuracy base for standardization and metrological traceability for triglyceride testing. The CA RMP has several disadvantages, including lack of ruggedness. It uses obsolete instrumentation and hazardous reagents. To overcome these problems the CDC developed an isotope dilution GC-MS (ID-GC-MS) RMP for total glycerides in serum. We diluted serum samples with Tris-HCl buffer solution and spiked 200-μL aliquots with [(13)C(3)]-glycerol. These samples were incubated and hydrolyzed under basic conditions. The samples were dried, derivatized with acetic anhydride and pyridine, extracted with ethyl acetate, and analyzed by ID-GC-MS. Linearity, imprecision, and accuracy were evaluated by analyzing calibrator solutions, 10 serum pools, and a standard reference material (SRM 1951b). The calibration response was linear for the range of calibrator concentrations examined (0-1.24 mmol/L) with a slope and intercept of 0.717 (95% CI, 0.7123-0.7225) and 0.3122 (95% CI, 0.3096-0.3140), respectively. The limit of detection was 14.8 μmol/L. The mean %CV for the sample set (serum pools and SRM) was 1.2%. The mean %bias from NIST isotope dilution MS values for SRM 1951b was 0.7%. This ID-GC-MS RMP has the specificity and ruggedness to accurately quantify total glycerides in the serum pools used in the CDC's Lipid Standardization Program and demonstrates sufficiently acceptable agreement with the NIST primary RMP for total glyceride measurement.

  11. Preparation and value assignment of standard reference material 968e fat-soluble vitamins, carotenoids, and cholesterol in human serum.

    PubMed

    Thomas, Jeanice B; Duewer, David L; Mugenya, Isaac O; Phinney, Karen W; Sander, Lane C; Sharpless, Katherine E; Sniegoski, Lorna T; Tai, Susan S; Welch, Michael J; Yen, James H

    2012-01-01

    Standard Reference Material 968e Fat-Soluble Vitamins, Carotenoids, and Cholesterol in Human Serum provides certified values for total retinol, γ- and α-tocopherol, total lutein, total zeaxanthin, total β-cryptoxanthin, total β-carotene, 25-hydroxyvitamin D(3), and cholesterol. Reference and information values are also reported for nine additional compounds including total α-cryptoxanthin, trans- and total lycopene, total α-carotene, trans-β-carotene, and coenzyme Q(10). The certified values for the fat-soluble vitamins and carotenoids in SRM 968e were based on the agreement of results from the means of two liquid chromatographic methods used at the National Institute of Standards and Technology (NIST) and from the median of results of an interlaboratory comparison exercise among institutions that participate in the NIST Micronutrients Measurement Quality Assurance Program. The assigned values for cholesterol and 25-hydroxyvitamin D(3) in the SRM are the means of results obtained using the NIST reference method based upon gas chromatography-isotope dilution mass spectrometry and liquid chromatography-isotope dilution tandem mass spectrometry, respectively. SRM 968e is currently one of two available health-related NIST reference materials with concentration values assigned for selected fat-soluble vitamins, carotenoids, and cholesterol in human serum matrix. This SRM is used extensively by laboratories worldwide primarily to validate methods for determining these analytes in human serum and plasma and for assigning values to in-house control materials. The value assignment of the analytes in this SRM will help support measurement accuracy and traceability for laboratories performing health-related measurements in the clinical and nutritional communities.

  12. Evaluation of a tunable bandpass reaction cell inductively coupled plasma mass spectrometer for the determination of selenium in serum and urine

    NASA Astrophysics Data System (ADS)

    Nixon, David E.; Neubauer, Kenneth R.; Eckdahl, Steven J.; Butz, John A.; Burritt, Mary F.

    2003-01-01

    A Dynamic Reaction Cell™ inductively coupled plasma mass spectrometer (DRC-ICP-MS) was evaluated for the determination of selenium in serum and urine. Reaction cell conditions were evaluated for the suppression of Ar 2+ dimer at m/ z 78 and 80 using methane as the reaction gas. A diluent containing 10% ethanol, 1% nitric acid, 0.5% Triton X-100 with gallium and yttrium internal standards was used to dilute urine and serum samples. Instrument response calibration was achieved by using aqueous acidic standards spiked into a urine matrix. Slopes for aqueous inorganic selenium, seleno- DL-cystine, seleno- DL-methionine and trimethylselenonium iodide spiked into urine and serum matrices were nearly identical. In general, reagent blank readings and detection limits were significantly lower in the DRC mode (reaction cell pressurized) than the standard mode (cell vented). Average results for the analysis of National Institute of Standards and Technology Standard Reference Material (NIST SRM) 1598 bovine serum (attained over 13 days) are: 43.8±3.6 μg Se/l. Reference concentration is 43.6±3.6 μg Se/l. For NIST SRM 2670 Normal Urine the DRC-ICP-MS results are 30.7±4.6 μg Se/l with a certified concentration of 30±8 μg Se/l. For NIST SRM 2670 Elevated Urine the DRC-ICP-MS results are 463±35 μg Se/l with a certified concentration of 460±30 μg Se/l. The DRC-ICP-MS results for selenium determinations in urine and serum survey samples from the Institut National de Sante Publique du Quebec were compared with the reference concentrations and results produced by conventional ICP-MS. While conventional ICP-MS gave acceptable results for survey samples, DRC-ICP-MS gave excellent results for both urine and sera. Closer correlation was observed for DRC-ICP-MS results with target concentrations than with conventional ICP-MS.

  13. The Kjeldahl method as a primary reference procedure for total protein in certified reference materials used in clinical chemistry. I. A review of Kjeldahl methods adopted by laboratory medicine.

    PubMed

    Chromý, Vratislav; Vinklárková, Bára; Šprongl, Luděk; Bittová, Miroslava

    2015-01-01

    We found previously that albumin-calibrated total protein in certified reference materials causes unacceptable positive bias in analysis of human sera. The simplest way to cure this defect is the use of human-based serum/plasma standards calibrated by the Kjeldahl method. Such standards, commutative with serum samples, will compensate for bias caused by lipids and bilirubin in most human sera. To find a suitable primary reference procedure for total protein in reference materials, we reviewed Kjeldahl methods adopted by laboratory medicine. We found two methods recommended for total protein in human samples: an indirect analysis based on total Kjeldahl nitrogen corrected for its nonprotein nitrogen and a direct analysis made on isolated protein precipitates. The methods found will be assessed in a subsequent article.

  14. Determination of serum calcium levels by 42Ca isotope dilution inductively coupled plasma mass spectrometry.

    PubMed

    Han, Bingqing; Ge, Menglei; Zhao, Haijian; Yan, Ying; Zeng, Jie; Zhang, Tianjiao; Zhou, Weiyan; Zhang, Jiangtao; Wang, Jing; Zhang, Chuanbao

    2017-11-27

    Serum calcium level is an important clinical index that reflects pathophysiological states. However, detection accuracy in laboratory tests is not ideal; as such, a high accuracy method is needed. We developed a reference method for measuring serum calcium levels by isotope dilution inductively coupled plasma mass spectrometry (ID ICP-MS), using 42Ca as the enriched isotope. Serum was digested with 69% ultrapure nitric acid and diluted to a suitable concentration. The 44Ca/42Ca ratio was detected in H2 mode; spike concentration was calibrated by reverse IDMS using standard reference material (SRM) 3109a, and sample concentration was measured by a bracketing procedure. We compared the performance of ID ICP-MS with those of three other reference methods in China using the same serum and aqueous samples. The relative expanded uncertainty of the sample concentration was 0.414% (k=2). The range of repeatability (within-run imprecision), intermediate imprecision (between-run imprecision), and intra-laboratory imprecision were 0.12%-0.19%, 0.07%-0.09%, and 0.16%-0.17%, respectively, for two of the serum samples. SRM909bI, SRM909bII, SRM909c, and GBW09152 were found to be within the certified value interval, with mean relative bias values of 0.29%, -0.02%, 0.10%, and -0.19%, respectively. The range of recovery was 99.87%-100.37%. Results obtained by ID ICP-MS showed a better accuracy than and were highly correlated with those of other reference methods. ID ICP-MS is a simple and accurate candidate reference method for serum calcium measurement and can be used to establish and improve serum calcium reference system in China.

  15. Hypolipidemic Effect of Red Gram (Cajanus cajan L.) Prebiotic Oligosaccharides in Wistar NIN Rats.

    PubMed

    Shakappa, Devindra; Talari, Aruna; Rajkumar, Hemalatha; Shujauddin, Mohammed

    2017-08-24

    The hypolipidemic effect of red gram prebiotics of raffinose family oligosaccharides was studied in Wistar National Institute of Nutrition male rat strain. The study consisted of 36 rats randomly divided into three groups of 12 rats each. For 16 weeks, Group I was fed with the control diet; Group II was fed with a diet containing 3% standard raffinose as the reference group; Group III received the diet containing 3% red gram prebiotics. The results showed that the gain in body weight was low in the red gram prebiotics-supplemented group followed by the control group; highest increase of body weight was seen in the raffinose standard-fed group. Serum glucose levels of the red gram prebiotic-fed group decreased 14.92% compared to the control group and increased 2.07% compared to the reference group. The decrease in serum triglycerides (TG) levels of the red gram prebiotic-fed groups was 32.76% compared to the control group and 33.64% compared to the reference group. Decrease in the serum TC of the red gram-fed animals was 18.51% and 4.63% compared to the control group and the reference group, respectively. Increase in the level of serum high-density lipoprotein cholesterol (HDL-C) in the red gram-fed animals was 18.51% compared to the control group and 4.63% compared to the reference group. The present study can be a proof for the use of prebiotics as a preventive measure for overweight and obesity in humans, and legume prebiotics can be explored as a novel prebiotic product in the consumer market.

  16. The International Standard for Anti-Brucella abortus Serum

    PubMed Central

    Stableforth, A. W.

    1954-01-01

    In field trials on the eradication of brucellosis from dairy herds in Great Britain, which began in 1933, a serum standard of reference was used for the examination of agglutinating suspensions prepared in different laboratories. In 1937, the Office International des Epizooties (OIE) adopted this standard and made recommendations for its use internationally. These recommendations were revised by OIE in 1948, by the Third Inter-American Congress on Brucellosis and by the Joint FAO/WHO Expert Panel on Brucellosis in 1950, and again by the latter body in 1952. A new batch equivalent in potency to the original standard was established by the WHO Expert Committee on Biological Standardization in 1952 as the International Standard for Anti-Brucella abortus Serum. The International Standard, or a national standard of equivalent potency, ensures comparability of the titres obtained in different countries by different methods, and the results of such comparisons can be expressed in a simple manner by describing the titres in terms of International Units of Brucella antibody. PMID:13199656

  17. Development of certified reference materials for electrolytes in human serum (GBW09124-09126).

    PubMed

    Feng, Liuxing; Wang, Jun; Cui, Yanjie; Shi, Naijie; Li, Haifeng; Li, Hongmei

    2017-05-01

    Three reference materials, at relatively low, middle, and high concentrations, were developed for analysis of the mass fractions of electrolytes (K, Ca, Na, Mg, Cl, and Li) in human serum. The reference materials were prepared by adding high purity chloride salts to normal human serum. The concentration range of the three levels is within ±20% of normal human serum. It was shown that 14 units with duplicate analysis is enough to demonstrate the homogeneity of these candidate reference materials. The statistical results also showed no significant trends in both short-term stability test for 1 week at 40 °C and long-term stability test for 14 months. The certification methods of the six elements include isotope dilution inductively coupled plasma mass spectrometry (ID-ICP-MS), inductively coupled plasma optical emission spectroscopy (ICP-OES), atomic absorption spectroscopy (AAS), ion chromatography (IC), and ion-selective electrode (ISE). The certification methods were validated by international comparisons among a number of national metrology institutes (NMIs). The combined relative standard uncertainties of the property values were estimated by considering the uncertainties of the analytical methods, homogeneity, and stability. The range of the expanded uncertainties of all the elements is from 2.2% to 3.9%. The certified reference materials (CRMs) are primarily intended for use in the calibration and validation of procedures in clinical analysis for the determination of electrolytes in human serum or plasma. Graphical Abstract Certified reference materials for K, Ca, Mg, Na, Cl and Li in human serum (GBW09124-09126).

  18. Committee on Diabetes Mellitus Indices of the Japan Society of Clinical Chemistry-recommended reference measurement procedure and reference materials for glycated albumin determination.

    PubMed

    Takei, Izumi; Hoshino, Tadao; Tominaga, Makoto; Ishibashi, Midori; Kuwa, Katsuhiko; Umemoto, Masao; Tani, Wataru; Okahashi, Mikiko; Yasukawa, Keiko; Kohzuma, Takuji; Sato, Asako

    2016-01-01

    Glycated albumin is an intermediate glycaemic control marker for which there are several measurement procedures with entirely different reference intervals. We have developed a reference measurement procedure for the purpose of standardizing glycated albumin measurements. The isotope dilution liquid chromatography/tandem mass spectrometry method was developed as a reference measurement procedure for glycated albumin. The stable isotopes of lysine and fructosyl-lysine, which serve as an internal standard, were added to albumin isolated from serum, followed by hydrogenation. After hydrolysis of albumin with hot hydrochloric acid, the liberated lysine and fructosyl-lysine were measured by liquid chromatography/tandem mass spectrometry, and their concentrations were determined from each isotope ratio. The reference materials (JCCRM611) for determining of glycated albumin were prepared from pooled patient blood samples. The isotope dilution-tandem mass spectrometry calibration curve of fructosyl-lysine and lysine showed good linearity (r = 0.999). The inter-assay and intra-assay coefficient of variation values of glycated albumin measurement were 1.2 and 1.4%, respectively. The glycated albumin values of serum in patients with diabetes assessed through the use of this method showed a good relationship with routine measurement procedures (r = 0.997). The relationship of glycated albumin values of the reference material (JCCRM611) between these two methods was the same as the relationship with the patient serum samples. The Committee on Diabetes Mellitus Indices of the Japan Society of Clinical Chemistry recommends the isotope dilution liquid chromatography/tandem mass spectrometry method as a reference measurement procedure, and JCCRM611 as a certified reference material for glycated albumin measurement. In addition, we recommend the traceability system for glycated albumin measurement. © The Author(s) 2015.

  19. Evaluation of Vitamin D Standardization Program protocols for standardizing serum 25-hydroxyvitamin D data: a case study of the program's potential for national nutrition and health surveys12345

    PubMed Central

    Cashman, Kevin D; Kiely, Mairead; Kinsella, Michael; Durazo-Arvizu, Ramón A; Tian, Lu; Zhang, Yue; Lucey, Alice; Flynn, Albert; Gibney, Michael J; Vesper, Hubert W; Phinney, Karen W; Coates, Paul M; Picciano, Mary F; Sempos, Christopher T

    2013-01-01

    Background: The Vitamin D Standardization Program (VDSP) has developed protocols for standardizing procedures of 25-hydroxyvitamin D [25(OH)D] measurement in National Health/Nutrition Surveys to promote 25(OH)D measurements that are accurate and comparable over time, location, and laboratory procedure to improve public health practice. Objective: We applied VDSP protocols to existing ELISA-derived serum 25(OH)D data from the Irish National Adult Nutrition Survey (NANS) as a case-study survey and evaluated their effectiveness by comparison of the protocol-projected estimates with those from a reanalysis of survey serums by using liquid chromatography–tandem mass spectrometry (LC–tandem MS). Design: The VDSP reference system and protocols were applied to ELISA-based serum 25(OH)D data from the representative NANS sample (n = 1118). A reanalysis of 99 stored serums by using standardized LC–tandem MS and resulting regression equations yielded predicted standardized serum 25(OH)D values, which were then compared with LC–tandem MS reanalyzed values for all serums. Results: Year-round prevalence rates for serum 25(OH)D concentrations <30, <40, and <50 nmol/L were 6.5%, 21.9%, and 40.0%, respectively, via original ELISA measurements and 11.4%, 25.3%, and 43.7%, respectively, when VDSP protocols were applied. Differences in estimates at <30- and <40-nmol/L thresholds, but not at the <50-nmol/L threshold, were significant (P < 0.05). A reanalysis of all serums by using LC–tandem MS confirmed prevalence estimates as 11.2%, 27.2%, and 45.0%, respectively. Prevalences of serum 25(OH)D concentrations >125 nmol/L were 1.2%, 0.3%, and 0.6% by means of ELISA, VDSP protocols, and LC–tandem MS, respectively. Conclusion: VDSP protocols hold a major potential for national nutrition and health surveys in terms of the standardization of serum 25(OH)D data. PMID:23615829

  20. Fundamental Importance of Reference Glucose Analyzer Accuracy for Evaluating the Performance of Blood Glucose Monitoring Systems (BGMSs).

    PubMed

    Bailey, Timothy S; Klaff, Leslie J; Wallace, Jane F; Greene, Carmine; Pardo, Scott; Harrison, Bern; Simmons, David A

    2016-07-01

    As blood glucose monitoring system (BGMS) accuracy is based on comparison of BGMS and laboratory reference glucose analyzer results, reference instrument accuracy is important to discriminate small differences between BGMS and reference glucose analyzer results. Here, we demonstrate the important role of reference glucose analyzer accuracy in BGMS accuracy evaluations. Two clinical studies assessed the performance of a new BGMS, using different reference instrument procedures. BGMS and YSI analyzer results were compared for fingertip blood that was obtained by untrained subjects' self-testing and study staff testing, respectively. YSI analyzer accuracy was monitored using traceable serum controls. In study 1 (N = 136), 94.1% of BGMS results were within International Organization for Standardization (ISO) 15197:2013 accuracy criteria; YSI analyzer serum control results showed a negative bias (-0.64% to -2.48%) at the first site and a positive bias (3.36% to 6.91%) at the other site. In study 2 (N = 329), 97.8% of BGMS results were within accuracy criteria; serum controls showed minimal bias (<0.92%) at both sites. These findings suggest that the ability to demonstrate that a BGMS meets accuracy guidelines is influenced by reference instrument accuracy. © 2016 Diabetes Technology Society.

  1. Development of a candidate reference measurement procedure for the analysis of cortisol in human serum samples by isotope dilution-gas chromatography-mass spectrometry.

    PubMed

    Kawaguchi, Migaku; Takatsu, Akiko

    2009-08-01

    A candidate reference measurement procedure involving isotope dilution coupled with gas chromatography-mass spectrometry (GC-MS) has been developed and critically evaluated. An isotopically labeled internal standard, cortisol-d(2), was added to a serum sample. After equilibration, solid-phase extractions (SPE) for sample preparation and derivatization with heptafluorobutyric anhydride (HFBA) were performed for GC-MS analysis. The limit of detection (LOD) and the limit of quantification (LOQ) were 5 and 20 ng g(-1), respectively. The recovery of the added cortisol ranged from 99.8 to 101.0%. Excellent precision was obtained with a within-day variation (RSD) of 0.7% for GC-MS analysis. The accuracy of the measurement was evaluated by comparing of results of this reference measurement procedure on lyophilized human serum reference materials for cortisol (European Reference Materials (ERM)-DA 192) as Certified Reference Materials (CRMs). The results of this method for total cortisol agreed with the certified values within some uncertainty. This method, which demonstrates simply, easy, good accuracy, high precision, and is free from interferences from structural analogues, qualifies as a reference measurement procedure.

  2. Comparison of RFFIT tests with different standard sera and testing procedures.

    PubMed

    Yu, Peng-cheng; Noguchi, Akira; Inoue, Satoshi; Tang, Qing; Rayner, Simon; Liang, Guo-dong

    2012-06-01

    The World Health Organization (WHO) standard assay for determining antibody level is the rapid fluorescent focus inhibition test (RFFIT) and is used to determine the degree of immunity after vaccination against rabies. To compare the difference in RFFIT results between the laboratories of The National Institute of Infectious Disease in Japan (NIID) and the Chinese Centre for Disease Control (CCDC) as well the influence of the choice of standard serum (STD) for the detection, the two laboratories detection methods were simultaneously manipulated by RFFIT. The reference serums used in NIID and the WHO standard serum used in CCDC were compared in the same RFFIT detection to determine the titer of four sera samples C1, S1, S2 and S4 in parallel, and the titers of the detected sera samples were calculated using the standard formula for neutralizing antibody titer. No significant difference was found in RFFIT methods from the two laboratories and the RFFIT testing procedures of the two laboratories have good consistency. However, different titers were obtained with the tentative internal standard serum (TI-STD) produced by adjusting to 2.0 IU of WHO standard serum in NIID and the WHO STD. The titer determined with the TI-STD was higher than that determined with WHO STD, This difference appears to be significant and requires further investigation.

  3. Evaluation of a tunable bandpass reaction cell for an inductively coupled plasma mass spectrometer for the determination of chromium and vanadium in serum and urine

    NASA Astrophysics Data System (ADS)

    Nixon, David E.; Neubauer, Kenneth R.; Eckdahl, Steven J.; Butz, John A.; Burritt, Mary F.

    2002-05-01

    A Dynamic Reaction Cell™ inductively coupled argon plasma mass spectrometer (DRC-ICP-MS) was evaluated for the determination of chromium and vanadium in serum and urine. Reaction cell conditions were evaluated for the elimination of ArC + and ClOH + interferences on chromium at mass 52 and OCl + on vanadium at mass 51. A diluent containing only 1% nitric acid and internal standards (Y and Ga) was used to prepare serum and urine for analysis. Instrument response calibration was achieved by using aqueous acidic standards spiked into pooled sera or urine matrices. The slopes of the calibration curves prepared in urine and serum matrices were nearly identical. On average, chromium detection limits are 2.5 times lower using the DRC than Zeeman graphite furnace atomic absorption spectrometry (ZGFAAS). Vanadium detection limits are approximately 50 times lower. Average detection limits achieved with DRC-ICP-MS are 0.075 μg Cr/l and 0.028 μg V/l. Average results for the analysis of National Institute of Standards and Technology Standard Reference Material (NIST SRM) 1598 Bovine Serum (attained over 22 days) are: 0.14 μg Cr/l and 0.068 μg V/l. The reference concentrations for vanadium and chromium in NIST SRM 1598 are (0.06) μg V/l and 0.14±0.08 μg Cr/l, respectively. Results for chromium and vanadium determinations on ICP-MS survey samples from the Toxocologie du Quebec are equivalent to those reported by high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for the same survey samples.

  4. Milk and serum standard reference materials for monitoring organic contaminants in human samples.

    PubMed

    Schantz, Michele M; Eppe, Gauthier; Focant, Jean-François; Hamilton, Coreen; Heckert, N Alan; Heltsley, Rebecca M; Hoover, Dale; Keller, Jennifer M; Leigh, Stefan D; Patterson, Donald G; Pintar, Adam L; Sharpless, Katherine E; Sjödin, Andreas; Turner, Wayman E; Vander Pol, Stacy S; Wise, Stephen A

    2013-02-01

    Four new Standard Reference Materials (SRMs) have been developed to assist in the quality assurance of chemical contaminant measurements required for human biomonitoring studies, SRM 1953 Organic Contaminants in Non-Fortified Human Milk, SRM 1954 Organic Contaminants in Fortified Human Milk, SRM 1957 Organic Contaminants in Non-Fortified Human Serum, and SRM 1958 Organic Contaminants in Fortified Human Serum. These materials were developed as part of a collaboration between the National Institute of Standards and Technology (NIST) and the Centers for Disease Control and Prevention (CDC) with both agencies contributing data used in the certification of mass fraction values for a wide range of organic contaminants including polychlorinated biphenyl (PCB) congeners, chlorinated pesticides, polybrominated diphenyl ether (PBDE) congeners, and polychlorinated dibenzo-p-dioxin (PCDD) and dibenzofuran (PCDF) congeners. The certified mass fractions of the organic contaminants in unfortified samples, SRM 1953 and SRM 1957, ranged from 12 ng/kg to 2200 ng/kg with the exception of 4,4'-DDE in SRM 1953 at 7400 ng/kg with expanded uncertainties generally <14 %. This agreement suggests that there were no significant biases existing among the multiple methods used for analysis.

  5. Milk and serum standard reference materials for monitoring organic contaminants in human samples

    PubMed Central

    Eppe, Gauthier; Focant, Jean-François; Hamilton, Coreen; Heckert, N. Alan; Heltsley, Rebecca M.; Hoover, Dale; Keller, Jennifer M.; Leigh, Stefan D.; Patterson, Donald G.; Pintar, Adam L.; Sharpless, Katherine E.; Sjödin, Andreas; Turner, Wayman E.; Vander Pol, Stacy S.; Wise, Stephen A.

    2016-01-01

    Four new Standard Reference Materials (SRMs) have been developed to assist in the quality assurance of chemical contaminant measurements required for human biomonitoring studies, SRM 1953 Organic Contaminants in Non-Fortified Human Milk, SRM 1954 Organic Contaminants in Fortified Human Milk, SRM 1957 Organic Contaminants in Non-Fortified Human Serum, and SRM 1958 Organic Contaminants in Fortified Human Serum. These materials were developed as part of a collaboration between the National Institute of Standards and Technology (NIST) and the Centers for Disease Control and Prevention (CDC) with both agencies contributing data used in the certification of mass fraction values for a wide range of organic contaminants including polychlorinated biphenyl (PCB) congeners, chlorinated pesticides, polybrominated diphenyl ether (PBDE) congeners, and polychlorinated dibenzo-p-dioxin (PCDD) and dibenzofuran (PCDF) congeners. The certified mass fractions of the organic contaminants in unfortified samples, SRM 1953 and SRM 1957, ranged from 12 ng/kg to 2200 ng/kg with the exception of 4,4′-DDE in SRM 1953 at 7400 ng/kg with expanded uncertainties generally <14 %. This agreement suggests that there were no significant biases existing among the multiple methods used for analysis. PMID:23132544

  6. Hematology and Serum Biochemistry Reference Intervals for Six-Week-Old, Farm-Reared Chinese Ring-Necked Pheasants ( Phasianus colchicus ) from Minnesota.

    PubMed

    Dzikamunhenga, R S; Griffith, R W; Hostetter, S; Fisher, P; Larson, W

    2017-06-01

    Chinese ring-necked pheasants ( Phasianus colchicus ) are commonly farmed in intensive operations for purposes such as meat production, hunting preserves, or research. Under these conditions, pheasants frequently suffer medical ailments such as bacterial, viral, and parasitic infections or nutritional or metabolic disorders. Relatively little scientific information exists regarding clinical pathology reference intervals (RIs) for farm-reared pheasants. The objective of this study was to determine RIs for hematologic and serum biochemical variables for Chinese ring-necked pheasants from Minnesota at 6 wk of age. Blood samples from 119 clinically healthy Chinese ring-necked pheasants were analyzed using standard techniques. Reference intervals were generated in Microsoft® Excel® 2013 (Microsoft, Redmond, WA) using Reference Value Advisor freeware version 2.1 (Microsoft). Ninety-five percent RIs were determined using nonparametric methods that followed Clinical and Laboratory Standards Institute guidelines. These RIs will be useful for the monitoring of health and diagnosis of disease in confined Chinese ring-necked pheasant populations that are approximately 6 wk old.

  7. Development of the Ion Exchange-Gravimetric Method for Sodium in Serum as a Definitive Method

    PubMed Central

    Moody, John R.; Vetter, Thomas W.

    1996-01-01

    An ion exchange-gravimetric method, previously developed as a National Committee for Clinical Laboratory Standards (NCCLS) reference method for the determination of sodium in human serum, has been re-evaluated and improved. Sources of analytical error in this method have been examined more critically and the overall uncertainties decreased. Additionally, greater accuracy and repeatability have been achieved by the application of this definitive method to a sodium chloride reference material. In this method sodium in serum is ion-exchanged, selectively eluted and converted to a weighable precipitate as Na2SO4. Traces of sodium eluting before or after the main fraction, and precipitate contaminants are determined instrumentally. Co-precipitating contaminants contribute less than 0.1 % while the analyte lost to other eluted ion-exchange fractions contributes less than 0.02 % to the total precipitate mass. With improvements, the relative expanded uncertainty (k = 2) of the method, as applied to serum, is 0.3 % to 0.4 % and is less than 0.1 % when applied to a sodium chloride reference material. PMID:27805122

  8. Fundamental Importance of Reference Glucose Analyzer Accuracy for Evaluating the Performance of Blood Glucose Monitoring Systems (BGMSs)

    PubMed Central

    Bailey, Timothy S.; Klaff, Leslie J.; Wallace, Jane F.; Greene, Carmine; Pardo, Scott; Harrison, Bern; Simmons, David A.

    2016-01-01

    Background: As blood glucose monitoring system (BGMS) accuracy is based on comparison of BGMS and laboratory reference glucose analyzer results, reference instrument accuracy is important to discriminate small differences between BGMS and reference glucose analyzer results. Here, we demonstrate the important role of reference glucose analyzer accuracy in BGMS accuracy evaluations. Methods: Two clinical studies assessed the performance of a new BGMS, using different reference instrument procedures. BGMS and YSI analyzer results were compared for fingertip blood that was obtained by untrained subjects’ self-testing and study staff testing, respectively. YSI analyzer accuracy was monitored using traceable serum controls. Results: In study 1 (N = 136), 94.1% of BGMS results were within International Organization for Standardization (ISO) 15197:2013 accuracy criteria; YSI analyzer serum control results showed a negative bias (−0.64% to −2.48%) at the first site and a positive bias (3.36% to 6.91%) at the other site. In study 2 (N = 329), 97.8% of BGMS results were within accuracy criteria; serum controls showed minimal bias (<0.92%) at both sites. Conclusions: These findings suggest that the ability to demonstrate that a BGMS meets accuracy guidelines is influenced by reference instrument accuracy. PMID:26902794

  9. Standard Specimen Reference Set: Colon — EDRN Public Portal

    Cancer.gov

    The Early Detection Research Network, Great Lakes-New England Clinical, Epidemiological and Validation Center (GLNE CVC) announces the availability of serum, plasma and urine samples for the early detection for colon cancer and validation studies.

  10. Reference ranges for serum total and monomeric prolactin for the current generation Abbott Architect assay.

    PubMed

    Whitehead, S J; Cornes, M P; Ford, C; Gama, R

    2015-01-01

    Exclusion of macroprolactinaemia, a well-recognised interference, as the cause of hyperprolactinaemia is essential to avoid potential misdiagnosis and mismanagement of patients. We have derived gender-specific serum total and post-polyethylene glycol (PEG) precipitation monomeric reference ranges for the recently re-standardised Abbott Architect prolactin assay. Prolactin was measured in serum samples obtained from males (n=49) and females (n=52) using the current Abbott Architect immunoassay pre- and post-PEG precipitation. Gender-specific reference ranges were derived for total and monomeric (post-PEG) prolactin. Routine patients' samples (n=175) with a serum total prolactin >700 mIU/L were screened for macroprolactinaemia to assess classification compared with our previous post-PEG precipitation percentage recovery-based approach. Reference ranges for serum total prolactin were 58-419 mIU/L (male) and 63-561 mIU/L (female). Male and female monomeric prolactin reference ranges were 32-309 mIU/L and 39-422 mIU/L, respectively. Mean (SD) post-PEG percentage recovery of the IS 84/500 prolactin standard was 80 (2.3)%. Of 175 patients' samples screened for macroprolactinaemia, 149 had monomeric prolactin concentrations (median monomeric prolactin=1035 mIU/L; median recovery=83%) above the gender-specific reference range. Monomeric prolactin concentrations (median monomeric prolactin=162 mIU/L; median recovery=20%) in the remaining 26 were within the reference ranges. One patient classified as macroprolactin positive and another classified as macroprolactin negative would not have been identified as such using the previous recovery-based approach. The use of post-PEG monomeric reference ranges not only identifies hyperprolactinaemia due solely to macroprolactinaemia but has the added advantage of identifying patients who have simultaneous true monomeric hyperprolactinaemia and elevated concentrations of macroprolactin. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  11. Serum Creatinine: Not So Simple!

    PubMed

    Delanaye, Pierre; Cavalier, Etienne; Pottel, Hans

    2017-01-01

    Measuring serum creatinine is cheap and commonly done in daily practice. However, interpretation of serum creatinine results is not always easy. In this review, we will briefly remind the physiological limitations of serum creatinine due notably to its tubular secretion and the influence of muscular mass or protein intake on its concentration. We mainly focus on the analytical limitations of serum creatinine, insisting on important concept such as reference intervals, standardization (and IDMS traceability), analytical interferences, analytical coefficient of variation (CV), biological CV and critical difference. Because the relationship between serum creatinine and glomerular filtration rate is hyperbolic, all these CVs will impact not only the precision of serum creatinine but still more the precision of different creatinine-based equations, especially in low or normal-low creatinine levels (or high or normal-high glomerular filtration rate range). © 2017 S. Karger AG, Basel.

  12. Standardization in laboratory medicine: Adoption of common reference intervals to the Croatian population.

    PubMed

    Flegar-Meštrić, Zlata; Perkov, Sonja; Radeljak, Andrea

    2016-03-26

    Considering the fact that the results of laboratory tests provide useful information about the state of health of patients, determination of reference value is considered an intrinsic part in the development of laboratory medicine. There are still huge differences in the analytical methods used as well as in the associated reference intervals which could consequently significantly affect the proper assessment of patient health. In a constant effort to increase the quality of patients' care, there are numerous international initiatives for standardization and/or harmonization of laboratory diagnostics in order to achieve maximum comparability of laboratory test results and improve patient safety. Through the standardization and harmonization processes of analytical methods the ability to create unique reference intervals is achieved. Such reference intervals could be applied globally in all laboratories using methods traceable to the same reference measuring system and analysing the biological samples from the populations with similar socio-demographic and ethnic characteristics. In this review we outlined the results of the harmonization processes in Croatia in the field of population based reference intervals for clinically relevant blood and serum constituents which are in accordance with ongoing activity for worldwide standardization and harmonization based on traceability in laboratory medicine.

  13. Standardization in laboratory medicine: Adoption of common reference intervals to the Croatian population

    PubMed Central

    Flegar-Meštrić, Zlata; Perkov, Sonja; Radeljak, Andrea

    2016-01-01

    Considering the fact that the results of laboratory tests provide useful information about the state of health of patients, determination of reference value is considered an intrinsic part in the development of laboratory medicine. There are still huge differences in the analytical methods used as well as in the associated reference intervals which could consequently significantly affect the proper assessment of patient health. In a constant effort to increase the quality of patients’ care, there are numerous international initiatives for standardization and/or harmonization of laboratory diagnostics in order to achieve maximum comparability of laboratory test results and improve patient safety. Through the standardization and harmonization processes of analytical methods the ability to create unique reference intervals is achieved. Such reference intervals could be applied globally in all laboratories using methods traceable to the same reference measuring system and analysing the biological samples from the populations with similar socio-demographic and ethnic characteristics. In this review we outlined the results of the harmonization processes in Croatia in the field of population based reference intervals for clinically relevant blood and serum constituents which are in accordance with ongoing activity for worldwide standardization and harmonization based on traceability in laboratory medicine. PMID:27019800

  14. Development of Standard Reference Materials to support assessment of iodine status for nutritional and public health purposes.

    PubMed

    Long, Stephen E; Catron, Brittany L; Boggs, Ashley Sp; Tai, Susan Sc; Wise, Stephen A

    2016-09-01

    The use of urinary iodine as an indicator of iodine status relies in part on the accuracy of the analytical measurement of iodine in urine. Likewise, the use of dietary iodine intake as an indicator of iodine status relies in part on the accuracy of the analytical measurement of iodine in dietary sources, including foods and dietary supplements. Similarly, the use of specific serum biomarkers of thyroid function to screen for both iodine deficiency and iodine excess relies in part on the accuracy of the analytical measurement of those biomarkers. The National Institute of Standards and Technology has been working with the NIH Office of Dietary Supplements for several years to develop higher-order reference measurement procedures and Standard Reference Materials to support the validation of new routine analytical methods for iodine in foods and dietary supplements, for urinary iodine, and for several serum biomarkers of thyroid function including thyroid-stimulating hormone, thyroglobulin, total and free thyroxine, and total and free triiodothyronine. These materials and methods have the potential to improve the assessment of iodine status and thyroid function in observational studies and clinical trials, thereby promoting public health efforts related to iodine nutrition. © 2016 American Society for Nutrition.

  15. Commercial radioimmunoassay for beta subunit of human chorionic gonadotropin: falsely positive determinations due to elevated serum luteinizing hormone

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fowler, J.E. Jr.; Platoff, G.E.; Kubrock, C.A.

    1982-01-01

    Among 17 men who had received seemingly curative treatment for unilateral non-seminomatous germ cell tumors for the testis and who had consistently normal serum human chorionic gonadotropin (HCG) levels at a reference laboratory, 7 (41%) had at least one falsely positive commercial serum HCG determination. To investigate the cause of these falsely positive determinations the authors measured the cross reactivity of luteinizing hormone (LH) and follicle stimulating hormone (FSH) standards in the commercial HCG assay, and studied the relationships between commercial HCG levels and serum LH levels, serum FSH levels and gonadal status in men with and without normal gonadalmore » function. The falsely positive HCG determinations appeared to be due to elevated serum LH levels and cross reactivity of LH in the commercial HCG assay because: 1) there was substantial cross reactivity of the LH standards in the commercial assay, 2) the serum LH was elevated in four of six men with solitary testes, 3) there was a striking correlation between elevated serum LH levels and falsely elevated commercial HCG levels in ten men with solitary or absent testes, and 4) there were no falsely positive HCG determinations in 13 normal men but there were falsely positive HCG determinations in seven of ten anorchid men.« less

  16. Assessment of criteria used by veterinary practitioners to diagnose hypothyroidism in sighthounds and investigation of serum thyroid hormone concentrations in healthy Salukis.

    PubMed

    Shiel, Robert E; Sist, MaryDee; Nachreiner, Raymond F; Ehrlich, Claire P; Mooney, Carmel T

    2010-02-01

    To assess use of serum thyroid hormone concentrations by veterinarians to diagnose hypothyroidism in sighthounds and to evaluate serum thyroid hormone concentrations in healthy Salukis. Retrospective case series and cross-sectional study. 398 sighthounds of various breeds with a diagnosis of hypothyroidism and 283 healthy Salukis. Pretreatment thyroid hormone assay results from sighthounds subsequently classified as hypothyroid by practitioners were retrieved from a laboratory database. In healthy Salukis, serum concentrations of total thyroxine (T(4)), free T(4), total triiodothyronine (T(3)), free T(3), and thyroid-stimulating hormone (TSH) and antibodies against thyroglobulin and thyroid hormones were assayed. Records indicated hypothyroidism had been diagnosed in 303 (76.1%) sight-hounds on the basis of low serum thyroid hormone concentrations alone and in 30 (7.5%) others despite all thyroid hormone indices being within reference limits. Only 65 (16.3%) dogs had a high TSH concentration or positive thyroglobulin autoantibody result to support the diagnosis. In healthy Salukis, median (reference limits) serum concentrations of total T(4), free T(4), total T(3), free T(3), and TSH were 13.0 nmol/L (2.8 to 40.0 nmol/L), 12.0 pmol/L (2.0 to 30.3 pmol/L), 1.0 nmol/L (0.4 to 2.1 nmol/L), 4.0 pmol/L (1.6 to 7.7 pmol/L), and 0.18 ng/mL (0 to 0.86 ng/mL), respectively. Diagnosis of hypothyroidism by practitioners was most often made without adequate supportive laboratory evidence. Thyroid hormone values in healthy Salukis differed markedly from standard reference limits for some, but not all, thyroid hormone indices. Breed-specific reference limits should be used when interpreting thyroid hormone profiles of sighthounds.

  17. Hypoxia-induced expression of VE-cadherin and filamin B in glioma cell cultures and pseudopalisade structures.

    PubMed

    Nissou, Marie-France; El Atifi, Michèle; Guttin, Audrey; Godfraind, Catherine; Salon, Caroline; Garcion, Emmanuel; van der Sanden, Boudewijn; Issartel, Jean-Paul; Berger, François; Wion, Didier

    2013-06-01

    Most of our knowledge regarding glioma cell biology comes from cell culture experiments. For many years the standards for glioma cell culture were the use of cell lines cultured in the presence of serum and 20 % O2. However, in vivo, normoxia in many brain areas is in close to 3 % O2. Hence, in cell culture, the experimental value referred as the norm is hyperoxic compared to any brain physiological value. Likewise, cells in vivo are not usually exposed to serum, and low-passaged glioma neurosphere cultures maintained in serum-free medium is emerging as a new standard. A consequence of changing the experimental normoxic standard from 20 % O2 to the more brain physiological value of 3 % O2, is that a 3 % O2 normoxic reference point enabled a more rigorous characterization of the level of regulation of genes by hypoxia. Among the glioma hypoxia-regulated genes characterized using this approach we found VE-cadherin that is required for blood vessel formation, and filamin B a gene involved in endothelial cell motility. Both VE-cadherin and filamin B were found expressed in pseudopalisades, a glioblastoma pathognomonic structure made of hypoxic migrating cancer cells. These results provide additional clues on the role played by hypoxia in the acquisition of endothelial traits by glioma cells and on the functional links existing between pseudopalisades, hypoxia, and tumor progression.

  18. The establishment of tocopherol reference intervals for Hungarian adult population using a validated HPLC method.

    PubMed

    Veres, Gábor; Szpisjak, László; Bajtai, Attila; Siska, Andrea; Klivényi, Péter; Ilisz, István; Földesi, Imre; Vécsei, László; Zádori, Dénes

    2017-09-01

    Evidence suggests that decreased α-tocopherol (the most biologically active substance in the vitamin E group) level can cause neurological symptoms, most likely ataxia. The aim of the current study was to first provide reference intervals for serum tocopherols in the adult Hungarian population with appropriate sample size, recruiting healthy control subjects and neurological patients suffering from conditions without symptoms of ataxia, myopathy or cognitive deficiency. A validated HPLC method applying a diode array detector and rac-tocol as internal standard was utilized for that purpose. Furthermore, serum cholesterol levels were determined as well for data normalization. The calculated 2.5-97.5% reference intervals for α-, β/γ- and δ-tocopherols were 24.62-54.67, 0.81-3.69 and 0.29-1.07 μm, respectively, whereas the tocopherol/cholesterol ratios were 5.11-11.27, 0.14-0.72 and 0.06-0.22 μmol/mmol, respectively. The establishment of these reference intervals may improve the diagnostic accuracy of tocopherol measurements in certain neurological conditions with decreased tocopherol levels. Moreover, the current study draws special attention to the possible pitfalls in the complex process of the determination of reference intervals as well, including the selection of study population, the application of internal standard and method validation and the calculation of tocopherol/cholesterol ratios. Copyright © 2017 John Wiley & Sons, Ltd.

  19. The usefulness of rapid point-of-care creatinine testing for the prevention of contrast-induced nephropathy in the emergency department.

    PubMed

    You, Je Sung; Chung, Yong Eun; Park, Jong Woo; Lee, Woonhyoung; Lee, Hye-Jeong; Chung, Tae Nyoung; Chung, Sung Phil; Park, Incheol; Kim, Seungho

    2013-07-01

    Renal dysfunction is the most important factor to consider when predicting a patient's risk of developing contrast-induced nephropathy (CIN). Measurement of creatinine (Cr) via rapid point-of-care blood urea nitrogen/creatinine testing (POCT-BUN/Cr) to determine CIN risk could potentially reduce the time required to achieve an accurate diagnosis and to initiate and complete treatment in the emergency department (ED). The aim of our study was to compare the results of POCT-BUN/Cr and reference laboratory tests for BUN and serum Cr. A retrospective analysis of suspected stroke patients who presented between November 2009 and November 2010, and had BUN and Cr levels measured by POCT-BUN/Cr, and the reference laboratory tests performed with the blood sample which was transferred to the central laboratory by an air-shoot system. Two assays were conducted on the whole blood (POCT) and serum (reference) by trained technicians. The time interval from arrival at the ED to reporting of the results was assessed for both assays via a computerised physician order entry system. The mean standard deviation (SD) interval from arrival at the ED to reporting of the results was 11.4 (4.9) min for POCT-BUN/Cr and 46.8 (38.5) min for the serum reference laboratory tests (p<0.001). Intra-class correlation coefficient (ICC) analysis demonstrated a high level of agreement (the consistency agreement) between POCT and the serum reference tests for both BUN (ICC=0.914) and Cr (ICC=0.980). This study suggests that POCT-BUN/Cr results correlate well with those of serum reference tests in terms of BUN and Cr levels and, in turn, predicting CIN. POCT-BUN/Cr is easily performed with a rapid turnaround time, suggesting its use in the ED may have substantial clinical benefit.

  20. World Reference Center for Arboviruses.

    DTIC Science & Technology

    1992-03-08

    resembling leptospirosis , many of the patients showing hemorrhagic manifestations. They were from two different regions of Sao Paulo State, one on the... bovine serum albumin as a standard. The presence of the M and E proteins in the extracellular particles was proved by the direct enzyme-linked

  1. Standard reference materials (SRMs) for determination of organic contaminants in environmental samples.

    PubMed

    Wise, Stephen A; Poster, Dianne L; Kucklick, John R; Keller, Jennifer M; Vanderpol, Stacy S; Sander, Lane C; Schantz, Michele M

    2006-10-01

    For the past 25 years the National Institute of Standards and Technology (NIST) has developed certified reference materials (CRMs), known as standard reference materials (SRMs), for determination of organic contaminants in environmental matrices. Assignment of certified concentrations has usually been based on combining results from two or more independent analytical methods. The first-generation environmental-matrix SRMs were issued with certified concentrations for a limited number (5 to 10) of polycyclic aromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs). Improvements in the analytical certification approach significantly expanded the number and classes of contaminants determined. Environmental-matrix SRMs currently available include air and diesel particulate matter, coal tar, marine and river sediment, mussel tissue, fish oil and tissue, and human serum, with concentrations typically assigned for 50 to 90 organic contaminants, for example PAHs, nitro-substituted PAHs, PCBs, chlorinated pesticides, and polybrominated diphenyl ethers (PBDEs).

  2. An improved reference measurement procedure for triglycerides and total glycerides in human serum by isotope dilution gas chromatography-mass spectrometry.

    PubMed

    Chen, Yizhao; Liu, Qinde; Yong, Sharon; Teo, Hui Ling; Lee, Tong Kooi

    2014-01-20

    Triglycerides are widely tested in clinical laboratories using enzymatic methods for lipid profiling. As enzymatic methods can be affected by interferences from biological samples, this together with the non-specific nature of triglycerides measurement makes it necessary to verify the accuracy of the test results with a reference measurement procedure. Several such measurement procedures had been published. These procedures generally involved lengthy and laborious sample preparation steps. In this paper, an improved reference measurement procedure for triglycerides and total glycerides was reported which simplifies the sample preparation steps and greatly shortens the time taken. The procedure was based on isotope dilution gas chromatography-mass spectrometry (IDGC-MS)with tripalmitin as the calibration standard. Serum samples were first spiked with isotope-labeled tripalmitin. For the measurement of triglycerides, the serum samples were subjected to lipid extraction followed by separation of triglycerides from diglycerides and monoglycerides. Triglycerides were then hydrolyzed to glycerol, derivatized and injected into the GC–MS for quantification. For the measurement of total glycerides, the serum samples were hydrolyzed directly and derivatized before injection into the GC-MS for quantification. All measurement results showed good precision with CV <1%. A certified reference material (CRM) of lipids in frozen human serum was used to verify the accuracy of the measurement. The obtained values for both triglycerides and total glycerides were well within the certified ranges of the CRM, with deviation <0.4% from the certified values. The relative expanded uncertainties were also comparable with the uncertainties associated with the certified values of the CRM. The validated procedure was used in an External Quality Assessment (EQA) Program organized by our laboratory to establish the assigned values for triglycerides and total glycerides.

  3. Clinical biochemistry of pregnant and nursing mares.

    PubMed

    Harvey, John W; Pate, Melanie G; Kivipelto, Jan; Asquith, Richard L

    2005-09-01

    Pregnancy and lactation result in increased metabolic demands. Although homeostatic mechanisms function to keep substances in blood at relatively constant levels, some changes in the concentrations of routine clinical chemistry analytes are likely to occur. The purpose of this study was to determine what physiological changes occur in serum clinical biochemistry analytes in pregnant and nursing mares, and to determine whether the changes were substantial enough to warrant separate reference intervals for pregnant or lactating horses. Forty-two Quarter Horse, Thoroughbred, Saddlebred, Standardbred and Morgan mares were entered into the study while pregnant. They were bled once each month through birth. Studies were continued on 20 mares until their foals were weaned. Test results were tabulated by time before or after birth. Serum biochemistry values were determined by standard methods using automated analyzers. Test results were analyzed using the Kruskal-Wallis 1-way ANOVA on ranks. If a significant difference was found (P<.05), Dunn's multiple comparison procedure was performed on all pairs. Results from pregnant and nursing mares also were compared with a reference group of 19 open, nonlactating mares. Serum triglyceride, potassium, creatinine, and total bilirubin concentrations were lower during lactation than during pregnancy. Serum calcium concentration also was slightly decreased at 2 time points during lactation. Triglyceride concentration was highest during midgestation, while bilirubin and creatinine values increased, and potassium and calcium remained constant during pregnancy. Serum urea concentration also remained constant during pregnancy but increased during lactation. Serum phosphate concentration was lowest during midgestation and highest during lactation. Total CO2 values were highest, and anion gaps were lowest, during midgestation. No significant differences were found in serum albumin, globulin, albumin:globulin ratio, total protein, or glucose values. When compared with the reference group of open mares, serum triglyceride, potassium, bilirubin, and total CO2 concentrations were lower, and anion gap was higher in horses that were nursing. Although most biochemical values remained relatively constant, significant differences were observed during pregnancy and lactation. Changes in the concentrations of triglycerides, potassium, bilirubin, total CO2, and anion gap during lactation were substantial enough to warrant separate reference intervals for lactating horses.

  4. A comparison of sperm agglutination and immobilization assays with a quantitative ELISA for anti-sperm antibody in serum.

    PubMed

    Lynch, D M; Leali, B A; Howe, S E

    1986-08-01

    An enzyme-linked immunosorbent assay (ELISA) that quantitates antisperm antibody in serum was compared with standard sperm agglutination and immobilization assays with the use of sera from 40 normal and 292 subfertile individuals. Quantitation of the assay was accomplished by standardizing assay parameters, including the incorporation of a standard reference curve, the number of whole target sperm, the optimal dilution of serum, the selection of microtiter plate, and the time and temperatures involved in the adsorption and incubation phases. With this method, the level of antisperm antibody binding to target sperm in 40 normal fertile individuals was found to be 2.3 (+/- 1.1 standard deviation [SD]) fg immunoglobulin (Ig)/sperm. An increased mean level of 7.4 +/- 3.7 fg Ig/sperm was determined in 84 infertile patients with positive agglutination and/or immobilization tests. In 208 individuals with negative agglutination and immobilization tests the mean concentration of antisperm antibody was 2.5 +/- 1.3 fg Ig/sperm. Postvasectomy patients assayed by this method had a mean Ig binding value of 7.1 +/- 2.4 fg Ig/sperm. The infertile group with positive agglutination and/or immobilization tests had a significantly higher mean antisperm antibody level than the normal fertile group, according to the Student's t-test for independent samples (P less than 0.001). This indirect serum-based assay reproducibly quantitates antisperm antibody binding to whole target sperm, suggests the normal and abnormal levels of antisperm antibody, and correlates with standard functional assays.

  5. Reference values assessment in a Mediterranean population for small dense low-density lipoprotein concentration isolated by an optimized precipitation method.

    PubMed

    Fernández-Cidón, Bárbara; Padró-Miquel, Ariadna; Alía-Ramos, Pedro; Castro-Castro, María José; Fanlo-Maresma, Marta; Dot-Bach, Dolors; Valero-Politi, José; Pintó-Sala, Xavier; Candás-Estébanez, Beatriz

    2017-01-01

    High serum concentrations of small dense low-density lipoprotein cholesterol (sd-LDL-c) particles are associated with risk of cardiovascular disease (CVD). Their clinical application has been hindered as a consequence of the laborious current method used for their quantification. Optimize a simple and fast precipitation method to isolate sd-LDL particles and establish a reference interval in a Mediterranean population. Forty-five serum samples were collected, and sd-LDL particles were isolated using a modified heparin-Mg 2+ precipitation method. sd-LDL-c concentration was calculated by subtracting high-density lipoprotein cholesterol (HDL-c) from the total cholesterol measured in the supernatant. This method was compared with the reference method (ultracentrifugation). Reference values were estimated according to the Clinical and Laboratory Standards Institute and The International Federation of Clinical Chemistry and Laboratory Medicine recommendations. sd-LDL-c concentration was measured in serums from 79 subjects with no lipid metabolism abnormalities. The Passing-Bablok regression equation is y = 1.52 (0.72 to 1.73) + 0.07 x (-0.1 to 0.13), demonstrating no significant statistical differences between the modified precipitation method and the ultracentrifugation reference method. Similarly, no differences were detected when considering only sd-LDL-c from dyslipidemic patients, since the modifications added to the precipitation method facilitated the proper sedimentation of triglycerides and other lipoproteins. The reference interval for sd-LDL-c concentration estimated in a Mediterranean population was 0.04-0.47 mmol/L. An optimization of the heparin-Mg 2+ precipitation method for sd-LDL particle isolation was performed, and reference intervals were established in a Spanish Mediterranean population. Measured values were equivalent to those obtained with the reference method, assuring its clinical application when tested in both normolipidemic and dyslipidemic subjects.

  6. Choice of Reference Serum Creatinine in Defining AKI

    PubMed Central

    Siew, Edward D.; Matheny, Michael E.

    2015-01-01

    Background/Aims The study of acute kidney injury (AKI) has expanded with the increasing availability of electronic health records and the use of standardized definitions. Understanding the impact of AKI between settings is limited by heterogeneity in the selection of reference creatinine to anchor the definition of AKI. In this mini-review, we discuss different approaches used to select reference creatinine and their relative merits and limitations. Methods We reviewed the literature to obtain representative examples of published baseline creatinine definitions when pre-hospital data were not available, as well as literature evaluating estimation of baseline renal function, using Pubmed and reference back-tracing within known works. Results 1) Prehospital creatinine values are useful in determining reference creatinine, and in high-risk populations, the mean outpatient serum creatinine value 7-365 days before hospitalization closely approximates nephrology adjudication, 2) in patients without pre-hospital data, the eGFR 75 approach does not reliably estimate true AKI incidence in most at-risk populations 3) using the lowest inpatient serum creatinine may be reasonable, especially in those with preserved kidney function, but may generously estimate AKI incidence and severity and miss community-acquired AKI that does not fully resolve, 4) using more specific definitions of AKI (e.g. KIDGO Stage 2 and 3) may help to reduce the effects of misclassification when using surrogate values, and 5) leveraging available clinical data may help refine the estimate of reference creatinine. Conclusions Choosing reference creatinine for AKI calculation is important for AKI classification and study interpretation. We recommend obtaining data on pre-hospital kidney function, wherever possible. In studies where surrogate estimates are used, transparency in how they are applied and discussion that informs the reader of potential biases should be provided. Further work to refine the estimation of reference creatinine is needed. PMID:26332325

  7. Glycerophosphate is interchangeable with inorganic phosphate in terms of safety and serum pharmacokinetics.

    PubMed

    Topp, Heinrich; Hochfeld, Olena; Bark, Staffan; Grossmann, Matthias; Joukhadar, Christian; Westphal, Martin; Straatsma, Harald; Rothenburger, Markus

    2011-01-01

    The primary aim of the present investigation was to determine and compare the pharmacokinetic (PK) profiles of inorganic phosphate in serum and urine after intravenous administration of sodium glycerophosphate and inorganic sodium phosphate. Additionally, study product safety profiles were evaluated. In total, 27 healthy, white volunteers (17 male/10 female) were enrolled in this double-blinded, randomized, 2-sequence, crossover study and were assigned to receive an organic test drug (sodium glycerophosphate) and an inorganic reference preparation (sodium phosphate) on 2 occasions. Validated analytical methods were used, and concentrations of total inorganic phosphate in serum and urine were determined over 24 h following a single 4-hour continuous intravenous infusion of test and reference drugs at a dose of 80 mmol. Study days were separated by washout periods of 7 days. An analysis of variance, based on population means and 90% confidence intervals (CIs), was used for testing bioequivalence (BE; range 0.8-1.25) between investigational products. The geometric means of the ratio of the point estimates and corresponding 90% CIs for the area under the concentration-versus-time curve of inorganic serum phosphate from 0 to 24 h (AUC(0-24)), the phosphate's maximum concentration in serum (C(max)) and the total amount of inorganic phosphate excreted in urine over 24 h corrected for individual baseline values (Ae(0-24 bc)) were estimated. The test/reference ratios for inorganic phosphate were 1.04 (CI 1.00-1.07), 0.85 (CI 0.84-0.87) and 0.84 (CI 0.77-0.92) for AUC(0-24), C(max) in serum and Ae(0-24 bc) in urine, respectively. Hence, standard BE criteria were met for AUC(0-24) and C(max) in serum, while Ae(0-24 bc) marginally failed to demonstrate BE. After drug administration, a total of 15 subjects reported the occurrence of at least 1 treatment emergent adverse event (AE). All AEs were classified as mild to moderate in severity, and the two treatment groups were equally affected. No serious AEs occurred. The serum PK profiles of inorganic phosphate were almost superimposable following intravenous administration of equimolar doses of test and reference drugs. Thus, we conclude that the two study drugs are essentially similar in terms of serum PK profiles, safety and tolerability. Copyright © 2011 S. Karger AG, Basel.

  8. Serum IGF-I and IGFBP-3 levels of Turkish children during childhood and adolescence: establishment of reference ranges with emphasis on puberty.

    PubMed

    Bereket, Abdullah; Turan, Serap; Omar, Anjumanara; Berber, Mustafa; Ozen, Ahmet; Akbenlioglu, Cengiz; Haklar, Goncagul

    2006-01-01

    We established age- and sex-related reference ranges for serum insulin-like growth factor-I (IGF-I) and insulin-like growth factor binding protein-3 (IGFBP-3) levels in 807 healthy Turkish children (428 boys, 379 girls), and constructed a model for calculation of standard deviation scores of IGF-I and IGFBP-3 according to age, sex and pubertal stage. Serum IGF-I and IGFBP-3 concentrations tended to be higher in girls compared to boys of the same ages, but the differences were statistically significant only in pubertal ages (9-14 years) for IGF-I and only in prepubertal ages for IGFBP-3 (6-8 years) (p < 0.05). Peak IGF-I concentrations were observed earlier in girls than boys (14 vs. 15 years, Tanner stage IV vs. V) starting to decline thereafter. IGFBP-3 levels peaked at age 13 and at Tanner stage IV in both sexes with a subsequent fall. Serum levels of IGF-I and IGFBP-3 increased steadily with age in the prepubertal stage followed by a rapid increase in IGF-I in the early pubertal stages. A relatively steeper increase in IGF-I but not in IGFBP-3 levels was observed at age 10-11 years in girls and at 12-13 years in boys which preceded the reported age of pubertal growth spurt. At late pubertal stages, both IGF-I and IGFBP-3 either did not change or decreased by increasing age. Interrelationships between growth factors and anthropometric measurements have been described, and the physiologic consequences of these have been discussed in detail. Differences in the pattern of IGF-I and IGFBP-3 in the present paper and those reported in other studies emphasize the importance of locally established reference ranges. Establishment of this reference data and a standard deviation score prediction model based on age, sex and puberty will enhance the diagnostic power and utility of IGF-I and IGFBP-3 in evaluating growth disorders in our population. Copyright 2006 S. Karger AG, Basel

  9. Standard Specimen Reference Set: Pancreatic — EDRN Public Portal

    Cancer.gov

    The primary objective of the EDRN Pancreatic Cancer Working Group Proposal is to create a reference set consisting of well-characterized serum/plasma specimens to use as a resource for the development of biomarkers for the early detection of pancreatic adenocarcinoma. The testing of biomarkers on the same sample set permits direct comparison among them; thereby, allowing the development of a biomarker panel that can be evaluated in a future validation study. Additionally, the establishment of an infrastructure with core data elements and standardized operating procedures for specimen collection, processing and storage, will provide the necessary preparatory platform for larger validation studies when the appropriate marker/panel for pancreatic adenocarcinoma has been identified.

  10. NHANES Monitoring of Serum 25-Hydroxyvitamin D: A Roundtable Summary123

    PubMed Central

    Yetley, Elizabeth A.; Pfeiffer, Christine M.; Schleicher, Rosemary L.; Phinney, Karen W.; Lacher, David A.; Christakos, Sylvia; Eckfeldt, John H.; Fleet, James C.; Howard, George; Hoofnagle, Andrew N.; Hui, Siu L.; Lensmeyer, Gary L.; Massaro, Joseph; Peacock, Munro; Rosner, Bernard; Wiebe, Donald; Bailey, Regan L.; Coates, Paul M.; Looker, Anne C.; Sempos, Christopher; Johnson, Clifford L.; Picciano, Mary Frances

    2010-01-01

    A roundtable to discuss monitoring of serum 25-hydroxyvitamin D [25(OH)D] in the NHANES was held in late July 2009. Topics included the following: 1) options for dealing with assay fluctuations in serum 25(OH)D in the NHANES conducted between 1988 and 2006; 2) approaches for transitioning between the RIA used in the NHANES between 1988 and 2006 to the liquid chromatography tandem MS (LC-MS/MS) measurement procedure to be used in NHANES 2007 and later; 3) approaches for integrating the recently available standard reference material for vitamin D in human serum (SRM 972) from the National Institute of Standards and Technology (NIST) into the NHANES; 4) questions regarding whether the C-3 epimer of 25-hydroxyvitamin D3 [3-epi-25(OH)D3] should be measured in NHANES 2007 and later; and 5) identification of research and educational needs. The roundtable experts agreed that the NHANES data needed to be adjusted to control for assay fluctuations and offered several options for addressing this issue. The experts suggested that the LC-MS/MS measurement procedure developed by NIST could serve as a higher order reference measurement procedure. They noted the need for a commutability study for the recently released NIST SRM 972 across a range of measurement procedures. They suggested that federal agencies and professional organizations work with manufacturers to improve the quality and comparability of measurement procedures across all laboratories. The experts noted the preliminary nature of the evidence of the 3-epi-25(OH)D3 but felt that it should be measured in 2007 NHANES and later. PMID:20881084

  11. Laboratory methodologies for indicators of iron status: strengths, limitations, and analytical challenges.

    PubMed

    Pfeiffer, Christine M; Looker, Anne C

    2017-12-01

    Biochemical assessment of iron status relies on serum-based indicators, such as serum ferritin (SF), transferrin saturation, and soluble transferrin receptor (sTfR), as well as erythrocyte protoporphyrin. These indicators present challenges for clinical practice and national nutrition surveys, and often iron status interpretation is based on the combination of several indicators. The diagnosis of iron deficiency (ID) through SF concentration, the most commonly used indicator, is complicated by concomitant inflammation. sTfR concentration is an indicator of functional ID that is not an acute-phase reactant, but challenges in its interpretation arise because of the lack of assay standardization, common reference ranges, and common cutoffs. It is unclear which indicators are best suited to assess excess iron status. The value of hepcidin, non-transferrin-bound iron, and reticulocyte indexes is being explored in research settings. Serum-based indicators are generally measured on fully automated clinical analyzers available in most hospitals. Although international reference materials have been available for years, the standardization of immunoassays is complicated by the heterogeneity of antibodies used and the absence of physicochemical reference methods to establish "true" concentrations. From 1988 to 2006, the assessment of iron status in NHANES was based on the multi-indicator ferritin model. However, the model did not indicate the severity of ID and produced categorical estimates. More recently, iron status assessment in NHANES has used the total body iron stores (TBI) model, in which the log ratio of sTfR to SF is assessed. Together, sTfR and SF concentrations cover the full range of iron status. The TBI model better predicts the absence of bone marrow iron than SF concentration alone, and TBI can be analyzed as a continuous variable. Additional consideration of methodologies, interpretation of indicators, and analytic standardization is important for further improvements in iron status assessment. © 2017 American Society for Nutrition.

  12. Blood lipid measurements. Variations and practical utility.

    PubMed

    Cooper, G R; Myers, G L; Smith, S J; Schlant, R C

    1992-03-25

    To describe the magnitude and impact of the major biological and analytical sources of variation in serum lipid and lipoprotein levels on risk of coronary heart disease; to present a way to qualitatively estimate the total intraindividual variation; and to demonstrate how to determine the number of specimens required to estimate, with 95% confidence, the "true" underlying total cholesterol value in the serum of a patient. Representative references on each source of variation were selected from more than 300 reviewed publications, most published within the past 5 years, to document current findings and concepts. Most articles reviewed were in English. Studies on biological sources of variation were selected using the following criteria: representative of published findings, clear statement of either significant or insignificant results, and acquisition of clinical and laboratory data under standardized conditions. Representative results for special populations such as women and children are reported when results differ from those of adult men. References were selected based on acceptable experimental design and use of standardized laboratory lipid measurements. The lipid levels considered representative for a selected source of variation arose from quantitative measurements by a suitably standardized laboratory. Statistical analysis of data was examined to assure reliability. The proposed method of estimating the biological coefficient of variation must be considered to give qualitative results, because only two or three serial specimens are collected in most cases for the estimation. Concern has arisen about the magnitude, impact, and interpretation of preanalytical as well as analytical sources of variation on reported results of lipid measurements of an individual. Preanalytical sources of variation from behavioral, clinical, and sampling sources constitute about 60% of the total variation in a reported lipid measurement of an individual. A technique is presented to allow physicians to qualitatively estimate the intraindividual biological variation of a patient from the results of two or more specimens reported from a standardized laboratory and to determine whether additional specimens are needed to meet the National Cholesterol Education Program recommendation that the intraindividual serum total cholesterol coefficient of variation not exceed 5.0. A National Reference Method Network has been established to help solve analytical problems.

  13. Role of the National Institute of Standards and Technology (NIST) in Support of the Vitamin D Initiative of the National Institutes of Health, Office of Dietary Supplements.

    PubMed

    Wise, Stephen A; Tai, Susan S-C; Burdette, Carolyn Q; Camara, Johanna E; Bedner, Mary; Lippa, Katrice A; Nelson, Michael A; Nalin, Federica; Phinney, Karen W; Sander, Lane C; Betz, Joseph M; Sempos, Christopher T; Coates, Paul M

    2017-09-01

    Since 2005, the National Institute of Standards and Technology (NIST) has collaborated with the National Institutes of Health (NIH), Office of Dietary Supplements (ODS) to improve the quality of measurements related to human nutritional markers of vitamin D status. In support of the NIH-ODS Vitamin D Initiative, including the Vitamin D Standardization Program (VDSP), NIST efforts have focused on (1) development of validated analytical methods, including reference measurement procedures (RMPs); (2) development of Standard Reference Materials (SRMs); (3) value assignment of critical study samples using NIST RMPs; and (4) development and coordination of laboratory measurement QA programs. As a result of this collaboration, NIST has developed RMPs for 25-hydroxyvitamin D2 [25(OH)D2], 25(OH)D3, and 24R,25-dihydroxyvitamin D3 [24R,25(OH)2D3]; disseminated serum-based SRMs with values assigned for 25(OH)D2, 25(OH)D3, 3-epi-25(OH)D3, and 24R,25(OH)2D3; assigned values for critical samples for VDSP studies, including an extensive interlaboratory comparison and reference material commutability study; provided an accuracy basis for the Vitamin D External Quality Assurance Scheme; coordinated the first accuracy-based measurement QA program for the determination of 25(OH)D2, 25(OH)D3, and 3-epi-25(OH)D3 in human serum/plasma; and developed methods and SRMs for the determination of vitamin D and 25(OH)D in food and supplement matrix SRMs. The details of these activities and their benefit and impact to the NIH-ODS Vitamin D Initiative are described.

  14. National Bone Health Alliance Bone Turnover Marker Project: current practices and the need for US harmonization, standardization, and common reference ranges.

    PubMed

    Bauer, D; Krege, J; Lane, N; Leary, E; Libanati, C; Miller, P; Myers, G; Silverman, S; Vesper, H W; Lee, D; Payette, M; Randall, S

    2012-10-01

    This position paper reviews how the National Bone Health Alliance (NBHA) will execute a project to help assure health professionals of the clinical utility of bone turnover markers; the current clinical approaches concerning osteoporosis and the status and use of bone turnover markers in the USA; the rationale for focusing this effort around two specific bone turnover markers; the need to standardize bone marker sample collection procedures, reference ranges, and bone turnover marker assays in clinical laboratories; and the importance of harmonization for future research of bone turnover markers. Osteoporosis is a major global health problem, with the prevalence and incidence of osteoporosis for at-risk populations estimated to be 44 million Americans. The potential of bone markers as an additional tool for health care professionals to improve patient outcomes and impact morbidity and mortality is crucial in providing better health care and addressing rising health care costs. This need to advance the field of bone turnover markers has been recognized by a number of organizations, including the International Osteoporosis Foundation (IOF), National Osteoporosis Foundation, International Federation of Clinical Chemistry, and Laboratory Medicine (IFCC), and the NBHA. This position paper elucidates how this project will standardize bone turnover marker sample collection procedures in the USA, establish a USA reference range for one bone formation (serum procollagen type I N propeptide, s-PINP) and one bone resorption (serum C-terminal telopeptide of type I collagen, s-CTX) marker, and standardize bone turnover marker assays used in clinical laboratories. This effort will allow clinicians from the USA to have confidence in their use of bone turnover markers to help monitor osteoporosis treatment and assess future fracture risk. This project builds on the recommendations of the IOF/IFCC Bone Marker Standards Working Group by developing USA reference standards for s-PINP and s-CTX, the markers identified as most promising for use as reference markers. The goals of this project will be realized through the NBHA and will include its governmental, academic, for-profit, and non-profit sector stakeholders as well as major academic and commercial laboratories. Upon completion, a parallel effort will be pursued to make bone turnover marker measurements reliable and accepted by all health care professionals for facilitating treatment decisions and ultimately be reimbursed by all health insurance payers. Successful completion of this project will help assure health professionals from the USA of the clinical utility of bone turnover markers and ties in with the parallel effort of the IOF/IFCC to develop worldwide bone turnover reference ranges.

  15. Reassessment of the Access Testosterone chemiluminescence assay and comparison with LC-MS method.

    PubMed

    Dittadi, Ruggero; Matteucci, Mara; Meneghetti, Elisa; Ndreu, Rudina

    2018-03-01

    To reassess the imprecision and Limit of Quantitation, to evaluate the cross-reaction with dehydroepiandrosterone-sulfate (DHEAS), the accuracy toward liquid chromatography-mass spectrometry (LC-MS) and the reference interval of the Access Testosterone method, performed by DxI immunoassay platform (Beckman Coulter). Imprecision was evaluated testing six pool samples assayed in 20 different run using two reagents lots. The cross-reaction with DHEAS was studied both by a displacement curve and by spiking DHEAS standard in two serum samples with known amount of testosterone. The comparison with LC-MS was evaluated by Passing-Bablock analysis in 21 routine serum samples and 19 control samples from an External Quality Assurance (EQA) scheme. The reference interval was verified by an indirect estimation on 2445 male and 2838 female outpatients. The imprecision study showed a coefficient of variation (CV) between 2.7% and 34.7% for serum pools from 16.3 and 0.27 nmol/L. The value of Limit of Quantitation at 20% CV was 0.53 nmol/L. The DHEAS showed a cross-reaction of 0.0074%. A comparison with LC-MS showed a trend toward a slight underestimation of immunoassay vs LC-MS (Passing-Bablock equations: DxI=-0.24+0.906 LCMS in serum samples and DxI=-0.299+0.981 LCMS in EQA samples). The verification of reference interval showed a 2.5th-97.5th percentile distribution of 6.6-24.3 nmol/L for male over 14 years and <0.5-2.78 nmol/L for female subjects, in accord with the reference intervals reported by the manufacturer. The Access Testosterone method could be considered an adequately reliable tool for the testosterone measurement. © 2017 Wiley Periodicals, Inc.

  16. Rapid and simple determination of selenium in blood serum by inductively coupled plasma-mass spectrometry (ICP-MS).

    PubMed

    Labat, L; Dehon, B; Lhermitte, M

    2003-05-01

    An inductively coupled plasma mass spectrometer (ICP-MS) with a rapid sample-preparative procedure was used for the determination of selenium in blood serum. Blood serum was prepared by dilution in an acidic solution consisting of nitric acid (1%), X-triton (0.1%) and 1-butanol (0.8%). A calibration curve was established for 1-40 microg mL(-1) (r(2)>0.99). The limit of detection was 0.5 microg mL(-1). Repeatability and intermediate precision were satisfactory with relative standard deviations (RSD) of 2.0% and 3.2%, respectively. This method was easily applied to reference materials with satisfactory accuracy. Good correlation (r(2)=0.96) was observed between ICP-MS and atomic absorption spectrometry (AAS) for the determination of (82)Se in blood serum from 23 patients. These results suggest that the sample preparative procedure coupled with ICP-MS can be used for the routine determination of (82)Se in human blood serum.

  17. Trueness verification of actual creatinine assays in the European market demonstrates a disappointing variability that needs substantial improvement. An international study in the framework of the EC4 creatinine standardization working group.

    PubMed

    Delanghe, Joris R; Cobbaert, Christa; Galteau, Marie-Madeleine; Harmoinen, Aimo; Jansen, Rob; Kruse, Rolf; Laitinen, Päivi; Thienpont, Linda M; Wuyts, Birgitte; Weykamp, Cas; Panteghini, Mauro

    2008-01-01

    The European In Vitro Diagnostics (IVD) directive requires traceability to reference methods and materials of analytes. It is a task of the profession to verify the trueness of results and IVD compatibility. The results of a trueness verification study by the European Communities Confederation of Clinical Chemistry (EC4) working group on creatinine standardization are described, in which 189 European laboratories analyzed serum creatinine in a commutable serum-based material, using analytical systems from seven companies. Values were targeted using isotope dilution gas chromatography/mass spectrometry. Results were tested on their compliance to a set of three criteria: trueness, i.e., no significant bias relative to the target value, between-laboratory variation and within-laboratory variation relative to the maximum allowable error. For the lower and intermediate level, values differed significantly from the target value in the Jaffe and the dry chemistry methods. At the high level, dry chemistry yielded higher results. Between-laboratory coefficients of variation ranged from 4.37% to 8.74%. Total error budget was mainly consumed by the bias. Non-compensated Jaffe methods largely exceeded the total error budget. Best results were obtained for the enzymatic method. The dry chemistry method consumed a large part of its error budget due to calibration bias. Despite the European IVD directive and the growing needs for creatinine standardization, an unacceptable inter-laboratory variation was observed, which was mainly due to calibration differences. The calibration variation has major clinical consequences, in particular in pediatrics, where reference ranges for serum and plasma creatinine are low, and in the estimation of glomerular filtration rate.

  18. Choice of Reference Serum Creatinine in Defining Acute Kidney Injury.

    PubMed

    Siew, Edward D; Matheny, Michael E

    2015-01-01

    The study of acute kidney injury (AKI) has expanded with the increasing availability of electronic health records and the use of standardized definitions. Understanding the impact of AKI between settings is limited by heterogeneity in the selection of reference creatinine to anchor the definition of AKI. In this mini-review, we discuss different approaches used to select reference creatinine and their relative merits and limitations. We reviewed the literature to obtain representative examples of published baseline creatinine definitions when pre-hospital data were not available, as well as literature evaluating the estimation of baseline renal function, using PubMed and reference back-tracing within known works. (1) Pre-hospital creatinine values are useful in determining reference creatinine, and in high-risk populations, the mean outpatient serum creatinine value 7-365 days before hospitalization closely approximates nephrology adjudication, (2) in patients without pre-hospital data, the eGFR 75 approach does not reliably estimate true AKI incidence in most at-risk populations, (3) using the lowest inpatient serum creatinine may be reasonable, especially in those with preserved kidney function, but may generously estimate AKI incidence and severity and miss community-acquired AKI that does not fully resolve, (4) using more specific definitions of AKI (e.g., KIDGO stages 2 and 3) may help to reduce the effects of misclassification when using surrogate values and (5) leveraging available clinical data may help refine the estimate of reference creatinine. Choosing reference creatinine for AKI calculation is important for AKI classification and study interpretation. We recommend obtaining data on pre-hospital kidney function, wherever possible. In studies where surrogate estimates are used, transparency in how they are applied and discussion that informs the reader of potential biases should be provided. Further work to refine the estimation of reference creatinine is needed. © 2015 S. Karger AG, Basel.

  19. Use of cerebrospinal fluid and serum samples impregnated on FTATM Elute filter paper for the diagnosis of infections caused by Neisseria meningitidis, Streptococcus pneumoniae and Haemophilus influenzae.

    PubMed

    Fukasawa, Lucila Okuyama; Gonçalves, Maria Gisele; Higa, Fábio Takenori; Castilho, Euclides Ayres; Ibarz-Pavón, Ana Belén; Sacchi, Claudio Tavares

    2017-01-01

    The lack of information regarding the burden of acute bacterial meningitis in Latin America leads to a reduction in the estimated incidence rates of the disease, and impairs public health decisions on the use and follow-up of preventive interventions, particularly, the evaluation of existing vaccination policies. The use of the real-time PCR in diagnostic routine procedures has resulted in a substantial increase in confirmed bacterial meningitis cases. However, in resource-poor countries, these assays are only available in reference laboratories. Sample transportation to these laboratories is a critical constraint, as it requires specialized, high cost courier services. To overcome this barrier we evaluated the use of FTATM Elute filter paper cards for the conservation and processing of samples under normal environmental conditions, as they would be when transported from remote and under-equipped healthcare facilities to the reference centers. A total of 401 samples received in 2015 as part of Sao Paulo's national surveillance for routine diagnosis were selected for this study. The sensitivity and specificity of real-time PCR were evaluated using fresh serum and cerebrospinal fluid (CSF) samples processed using our laboratory's standard DNA extraction, and processing the same samples after being dried and stored on FTATM card, and DNA extracted following the manufacturer's instructions. The sensitivities for detection of Neisseria meningitidis, Streptococcus pneumoniae, and Haemophilus influenzae from CSF dried and stored on FTATM cards were 98%, 92%, and 100%, respectively, and with serum samples were 73%, 88%, and 100%, respectively. When compared to our laboratory's standard methodology, results showed high concordance, with Kappa index ranges of 0.9877-1.00 for CSF, and 0.8004-1.00 for serum samples. The use of FTATM cards for CSF and serum conservation and transport represents a rapid, reliable, and cost-effective alternative that will allow obtaining valuable epidemiological information that would otherwise be lost.

  20. Influence of the incubation temperature and the batch components on the sensitivity of an enzyme-linked immunosorbent assay to detect Aujeszky's disease virus glycoprotein E (gE).

    PubMed

    Cay, A B; Van der Stede, Y

    2010-12-01

    Although licensed batches of an enzyme-linked immunosorbent assay (ELISA) for Aujeszky's disease virus (ADV) were used, and the assays were performed within an ISO/IEC 17025 accredited quality control system, certain routine runs of the ADV ELISA were not validated using the quality system criteria, even when all technical parameters were controlled. Incubation at different temperatures and batch composition were identified as parameters that could result in non-validated assays/runs. Therefore, the effect of incubation temperature and batch composition on the analytical sensitivity of the ELISA was investigated. The World Organisation for Animal Health (OIE) standard reference serum ADV1 was diluted 1:8 and tested in 94 different glycoprotein E ELISA runs performed with different batches and different incubation temperatures. The incubation temperature and batch components had a significant influence on the qualitative result for the OIE standard reference serum. An incubation temperature of at least 22 degrees C was recommended, based on the results of this analysis. Which of the batch components caused these differences in sensitivity was not investigated further.

  1. Comparison of Three Enzyme-Linked Immunosorbent Assays for Detection of Immunoglobulin G Antibodies to Tetanus Toxoid with Reference Standards and the Impact on Clinical Practice▿

    PubMed Central

    van Hoeven, Karen H.; Dale, Connie; Foster, Phil; Body, Barbara

    2008-01-01

    Accurate determination of the concentrations of immunoglobulin G (IgG) antibody to tetanus toxoid is important in order to evaluate the immunogenicity of tetanus toxoid vaccines, determine immune competence in individual patients, and measure the prevalence of immunity in populations. The performance of three commercially available enzyme-linked immunosorbent assays (ELISAs) for IgG antibodies to tetanus toxoid were evaluated. Serially diluted NIBSC 76/589 and TE-3 human tetanus IgG immunoglobulin international reference standards were analyzed in quadruplicate using ELISAs manufactured by The Binding Site, Inc. (VaccZyme); Scimedx; and Euroimmun. In addition, IgG antibodies to tetanus toxoid were measured in 83 deidentified serum specimens using each manufacturer's ELISA. Each ELISA provided linear results when evaluated with the reference preparations. The Binding Site ELISA provided results that closely corresponded to the reference preparations (y = 1.09x − 0.08), whereas the Scimedx ELISA gave results that were consistently lower (y = 0.21x − 0.07) and the Euroimmun ELISA gave results that were consistently higher (y = 1.5x + 0.30) than the reference preparation concentrations. Using the recommended cutoff for each ELISA (<0.10 IU/ml), the overall agreement of all of the ELISA methods was 78%. Three of eighty-three (3.6%) human serum samples demonstrated inadequate immunity with all three assays. The Binding Site ELISA yielded nonprotective antibody concentrations in only these 3 samples, whereas 19 samples (22.9%) according to the Scimedx ELISA and 6 samples (7.2%) according to the Euroimmun ELISA demonstrated nonprotective concentrations. The performance characteristics of ELISAs for tetanus immunoglobulin titers were manufacturer dependent, and the differences translated into important disparities in reported results. PMID:18845832

  2. Role of chromatography in the development of Standard Reference Materials for organic analysis.

    PubMed

    Wise, Stephen A; Phinney, Karen W; Sander, Lane C; Schantz, Michele M

    2012-10-26

    The certification of chemical constituents in natural-matrix Standard Reference Materials (SRMs) at the National Institute of Standards and Technology (NIST) can require the use of two or more independent analytical methods. The independence among the methods is generally achieved by taking advantage of differences in extraction, separation, and detection selectivity. This review describes the development of the independent analytical methods approach at NIST, and its implementation in the measurement of organic constituents such as contaminants in environmental materials, nutrients and marker compounds in food and dietary supplement matrices, and health diagnostic and nutritional assessment markers in human serum. The focus of this review is the important and critical role that separation science techniques play in achieving the necessary independence of the analytical steps in the measurement of trace-level organic constituents in natural matrix SRMs. Published by Elsevier B.V.

  3. [Diagnostic kits in parasitology: which controls?].

    PubMed

    Rossi, P

    2004-06-01

    The development of new diagnostic tools particularly for some parasitic "neglected diseases", is slowed or even hindered by limited resources assigned for basic and applied research in public institution and private sector. Even if the time-line and costs needed for developing a new In Vitro Diagnostic (IVD) test are generally lower compared to vaccines or new drugs, industry is poorly engaged in investing resources due to the perception of limited markets. To accelerate the development of diagnostics for the world's most deadly diseases, the World Health Organization's (WHO) Special Programme for Research and Training in Tropical Diseases (TDR), the United Nations Development Programme, the World Bank and the Gates Foundation, last year launched a new initiative, FIND (Foundation for Innovative New Diagnostics, www.finddiagnostics.org). The aim is to "apply the latest biotechnology innovations to develop and validate affordable diagnostic tests for diseases of the developing world". Ideally, a new diagnostic test should be accurately evaluated prior to use in medical practice. The first step would be a pre-clinical evaluation, an analytic study to determine its laboratory performance. A crucial point in this phase is the calibration of reagents (antigens, antibodies, DNA probes, etc.) against a standard reference preparation. WHO, through the WHO International Laboratories for Biological Standards, "provides International Biological Reference Preparations which serve as reference sources of defined biological activity expressed in an internationally agreed unit" (www.who.int/biologicals/IBRP/index.htm). Standardization allows "comparison of biological measurements worldwide" and ensures the reliability of diagnostic procedures. These preparations are generally intended for use in the characterization of the activity of secondary reference preparations (regional, national or in-house working standards). Unfortunately, international reference standards for parasitic diseases are not available at present, except for Toxoplasma antibodies. The first international standard reagent for Anti-Toxoplasma Serum was established in 1968 and at present, an international standard reference serum, Anti-toxoplasma serum, human TOXM is available at the National Institute for Biological Standards and Control (NIBSC) in UK. Several collaborative, multicenter studies were carried out to assess the performance of different methods and commercial tests for the diagnosis of toxoplasmosis, by providing to participating laboratories a panel of well-defined sera to be tested. A four-phase process following well-accepted methodological standards for the development of diagnostics, analogous to those internationally accepted for drugs and vaccines was recently proposed. The pre-clinical evaluation, the analytic study to assess sensitivity, specificity, predictive values in laboratory (phase I), should be followed by a proof of principle study to distinguish diseased from healthy persons in easily accessible populations (phase II). The evaluation of test performance in populations of intended use (phase III), and finally the delineation of cost-effectiveness and societal impact of new tests in comparison with existing tools (phase IV) should complete the validation procedure. In this context, national regulatory agencies play a major role in pre-market approval and post-market surveillance of IVDs. The European Community in 1998 approved a directive (Directive 98/79/EC) which rules the marketing of IVD medical devices, in order to harmonise the performance levels and standards in European countries. But, among IVDs for parasitic diseases, only those to detect congenital toxoplasmosis are submitted to defined procedures to provide the verification of products before their placing on the market and the surveillance after their marketing by a notified body, which perform appropriate examinations, tests and inspections to production facilities to verify if the device meets the requirements of the directive. In U.S.A., the Food and Drug Administration (FDA), through the Office of In Vitro Diagnostic Device Evaluation and Safety (OIVD), provides a comprehensive and regulatory activity for IVDs through pre-market evaluation and post-market surveillance. In developing countries, the scarcity of resources limits the procedures through which the national control authority can assure safety, quality and efficacy of products marketed, both imported and locally manufactured.

  4. How do gait frequency and serum-replacement interval affect polyethylene wear in knee-wear simulator tests?

    PubMed

    Reinders, Jörn; Sonntag, Robert; Kretzer, Jan Philippe

    2014-11-01

    Polyethylene wear (PE) is known to be a limiting factor in total joint replacements. However, a standardized wear test (e.g. ISO standard) can only replicate the complex in vivo loading condition in a simplified form. In this study, two different parameters were analyzed: (a) Bovine serum, as a substitute for synovial fluid, is typically replaced every 500,000 cycles. However, a continuous regeneration takes place in vivo. How does serum-replacement interval affect the wear rate of total knee replacements? (b) Patients with an artificial joint show reduced gait frequencies compared to standardized testing. What is the influence of a reduced frequency? Three knee wear tests were run: (a) reference test (ISO), (b) testing with a shortened lubricant replacement interval, (c) testing with reduced frequency. The wear behavior was determined based on gravimetric measurements and wear particle analysis. The results showed that the reduced test frequency only had a small effect on wear behavior. Testing with 1 Hz frequency is therefore a valid method for wear testing. However, testing with a shortened replacement interval nearly doubled the wear rate. Wear particle analysis revealed only small differences in wear particle size between the different tests. Wear particles were not linearly released within one replacement interval. The ISO standard should be revised to address the marked effects of lubricant replacement interval on wear rate.

  5. Use of Fourier-transform infrared spectroscopy to quantify immunoglobulin G concentrations in alpaca serum.

    PubMed

    Burns, J; Hou, S; Riley, C B; Shaw, R A; Jewett, N; McClure, J T

    2014-01-01

    Rapid, economical, and quantitative assays for measurement of camelid serum immunoglobulin G (IgG) are limited. In camelids, failure of transfer of maternal immunoglobulins has a reported prevalence of up to 20.5%. An accurate method for quantifying serum IgG concentrations is required. To develop an infrared spectroscopy-based assay for measurement of alpaca serum IgG and compare its performance to the reference standard radial immunodiffusion (RID) assay. One hundred and seventy-five privately owned, healthy alpacas. Eighty-two serum samples were collected as convenience samples during routine herd visits whereas 93 samples were recruited from a separate study. Serum IgG concentrations were determined by RID assays and midinfrared spectra were collected for each sample. Fifty samples were set aside as the test set and the remaining 125 training samples were employed to build a calibration model using partial least squares (PLS) regression with Monte Carlo cross validation to determine the optimum number of PLS factors. The predictive performance of the calibration model was evaluated by the test set. Correlation coefficients for the IR-based assay were 0.93 and 0.87, respectively, for the entire data set and test set. Sensitivity in the diagnosis of failure of transfer of passive immunity (FTPI) ([IgG] <1,000 mg/dL) was 71.4% and specificity was 100% for the IR-based method (test set) as gauged relative to the RID reference method assay. This study indicated that infrared spectroscopy, in combination with chemometrics, is an effective method for measurement of IgG in alpaca serum. Copyright © 2014 by the American College of Veterinary Internal Medicine.

  6. Determination of toxic and essential trace elements in serum of healthy and hypothyroid respondents by ICP-MS: A chemometric approach for discrimination of hypothyroidism.

    PubMed

    Stojsavljević, Aleksandar; Trifković, Jelena; Rasić-Milutinović, Zorica; Jovanović, Dragana; Bogdanović, Gradimir; Mutić, Jelena; Manojlović, Dragan

    2018-07-01

    Inductively coupled plasma-mass spectrometry ((ICP-MS)) was used to determine three toxic (Ni, As, Cd) and six essential trace elements (Cr, Mn, Co, Cu, Zn, Se) in blood serum of patients with hypothyroidism (Hy group) and healthy people (control group), in order to set the experimental conditions for accurate determination of a unique profile of these elements in hypothyroidism. Method validation was performed with standard reference material of the serum by varying the sample treatment with both standard and collision mode for analysis of elements isotopes. Quadratic curvilinear functions with good performances of models and the lowest detection limits were obtained for 52 Cr, 66 Zn, 75 As, 112 Cd in collision mode, and 55 Mn, 59 Co, 60 Ni, 65 Cu, 78 Se in standard mode. Treatment of serum samples with aqueous solution containing nitric acid, Triton X-100 and n-butanol gave the best results. Chemometric tools were applied for discrimination of patients with hypothyroidism. All nine elements discriminated Hy group of samples with almost the same discriminating power as indicated by their higher values for this group of patients. Statistically significant correlation (p < 0.01) was observed for several elements. Results indicated clear differences in element profile between Hy and control group and it could be used as a unique profile of hypothyroid state. Copyright © 2018 Elsevier GmbH. All rights reserved.

  7. Accurate quantification of creatinine in serum by coupling a measurement standard to extractive electrospray ionization mass spectrometry

    NASA Astrophysics Data System (ADS)

    Huang, Keke; Li, Ming; Li, Hongmei; Li, Mengwan; Jiang, You; Fang, Xiang

    2016-01-01

    Ambient ionization (AI) techniques have been widely used in chemistry, medicine, material science, environmental science, forensic science. AI takes advantage of direct desorption/ionization of chemicals in raw samples under ambient environmental conditions with minimal or no sample preparation. However, its quantitative accuracy is restricted by matrix effects during the ionization process. To improve the quantitative accuracy of AI, a matrix reference material, which is a particular form of measurement standard, was coupled to an AI technique in this study. Consequently the analyte concentration in a complex matrix can be easily quantified with high accuracy. As a demonstration, this novel method was applied for the accurate quantification of creatinine in serum by using extractive electrospray ionization (EESI) mass spectrometry. Over the concentration range investigated (0.166 ~ 1.617 μg/mL), a calibration curve was obtained with a satisfactory linearity (R2 = 0.994), and acceptable relative standard deviations (RSD) of 4.6 ~ 8.0% (n = 6). Finally, the creatinine concentration value of a serum sample was determined to be 36.18 ± 1.08 μg/mL, which is in excellent agreement with the certified value of 35.16 ± 0.39 μg/mL.

  8. Current Practices of Measuring and Reference Range Reporting of Free and Total Testosterone in the United States.

    PubMed

    Le, Margaret; Flores, David; May, Danica; Gourley, Eric; Nangia, Ajay K

    2016-05-01

    The evaluation and management of male hypogonadism should be based on symptoms and on serum testosterone levels. Diagnostically this relies on accurate testing and reference values. Our objective was to define the distribution of reference values and assays for free and total testosterone by clinical laboratories in the United States. Upper and lower reference values, assay methodology and source of published reference ranges were obtained from laboratories across the country. A standardized survey was reviewed with laboratory staff via telephone. Descriptive statistics were used to tabulate results. We surveyed a total of 120 laboratories in 47 states. Total testosterone was measured in house at 73% of laboratories. At the remaining laboratories studies were sent to larger centralized reference facilities. The mean ± SD lower reference value of total testosterone was 231 ± 46 ng/dl (range 160 to 300) and the mean upper limit was 850 ± 141 ng/dl (range 726 to 1,130). Only 9% of laboratories where in-house total testosterone testing was performed created a reference range unique to their region. Others validated the instrument recommended reference values in a small number of internal test samples. For free testosterone 82% of laboratories sent testing to larger centralized reference laboratories where equilibrium dialysis and/or liquid chromatography with mass spectrometry was done. The remaining laboratories used published algorithms to calculate serum free testosterone. Reference ranges for testosterone assays vary significantly among laboratories. The ranges are predominantly defined by limited population studies of men with unknown medical and reproductive histories. These poorly defined and variable reference values, especially the lower limit, affect how clinicians determine treatment. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  9. Reference interval for thyrotropin in a ultrasonography screened Korean population

    PubMed Central

    Kim, Mijin; Kim, Soo Han; Lee, Yunkyoung; Park, Su-yeon; Kim, Hyung-don; Kwon, Hyemi; Choi, Yun Mi; Jang, Eun Kyung; Jeon, Min Ji; Kim, Won Gu; Shong, Young Kee; Kim, Won Bae

    2015-01-01

    Background/Aims The diagnostic accuracy of thyroid dysfunctions is primarily affected by the validity of the reference interval for serum thyroid-stimulating hormone (TSH). Thus, the present study aimed to establish a reference interval for TSH using a normal Korean population. Methods This study included 19,465 subjects who were recruited after undergoing routine health check-ups. Subjects with overt thyroid disease, a prior history of thyroid disease, or a family history of thyroid cancer were excluded from the present analyses. The reference range for serum TSH was evaluated in a normal Korean reference population which was defined according to criteria based on the guidelines of the National Academy of Clinical Biochemistry, ultrasound (US) findings, and smoking status. Sex and age were also taken into consideration when evaluating the distribution of serum TSH levels in different groups. Results In the presence of positive anti-thyroid peroxidase antibodies or abnormal US findings, the central 95 percentile interval of the serum TSH levels was widened. Additionally, the distribution of serum TSH levels shifted toward lower values in the current smokers group. The reference interval for TSH obtained using a normal Korean reference population was 0.73 to 7.06 mIU/L. The serum TSH levels were higher in females than in males in all groups, and there were no age-dependent shifts. Conclusions The present findings demonstrate that the serum TSH reference interval in a normal Korean reference population was higher than that in other countries. This result suggests that the upper and lower limits of the TSH reference interval, which was previously defined by studies from Western countries, should be raised for Korean populations. PMID:25995664

  10. Harmonising Reference Intervals for Three Calculated Parameters used in Clinical Chemistry.

    PubMed

    Hughes, David; Koerbin, Gus; Potter, Julia M; Glasgow, Nicholas; West, Nic; Abhayaratna, Walter P; Cavanaugh, Juleen; Armbruster, David; Hickman, Peter E

    2016-08-01

    For more than a decade there has been a global effort to harmonise all phases of the testing process, with particular emphasis on the most frequently utilised measurands. In addition, it is recognised that calculated parameters derived from these measurands should also be a target for harmonisation. Using data from the Aussie Normals study we report reference intervals for three calculated parameters: serum osmolality, serum anion gap and albumin-adjusted serum calcium. The Aussie Normals study was an a priori study that analysed samples from 1856 healthy volunteers. The nine analytes used for the calculations in this study were measured on Abbott Architect analysers. The data demonstrated normal (Gaussian) distributions for the albumin-adjusted serum calcium, the anion gap (using potassium in the calculation) and the calculated serum osmolality (using both the Bhagat et al. and Smithline and Gardner formulae). To assess the suitability of these reference intervals for use as harmonised reference intervals, we reviewed data from the Royal College of Pathologists of Australasia/Australasian Association of Clinical Biochemists (RCPA/AACB) bias survey. We conclude that the reference intervals for the calculated serum osmolality (using the Smithline and Gardner formulae) may be suitable for use as a common reference interval. Although a common reference interval for albumin-adjusted serum calcium may be possible, further investigations (including a greater range of albumin concentrations) are needed. This is due to the bias between the Bromocresol Green (BCG) and Bromocresol Purple (BCP) methods at lower serum albumin concentrations. Problems with the measurement of Total CO 2 in the bias survey meant that we could not use the data for assessing the suitability of a common reference interval for the anion gap. Further study is required.

  11. Immunoturbidimetric quantification of serum immunoglobulin G concentration in foals.

    PubMed

    Bauer, J E; Brooks, T P

    1990-08-01

    Immunoturbidimetric determination of serum IgG concentration in foals was compared with the reference methods of single radial immunodiffusion and serum protein electrophoresis. High positive correlations were discovered when the technique was compared with either of these reference methods. The zinc sulfate turbidity test for serum IgG estimation was also evaluated. Although a positive correlation was discovered when the latter method was compared with reference methods, it was not as strong as the correlation between reference methods and the immunoturbidimetric method. The immunoturbidimetric method used in this study is specific and precise for equine serum IgG determination. It is rapid and, thus, is advantageous when timely evaluation of critically ill foals is necessary. The technique should be adaptable to various spectrophotometers and microcomputers for widespread application in veterinary medicine.

  12. Large-scale identification of core-fucosylated glycopeptide sites in pancreatic cancer serum using mass spectrometry.

    PubMed

    Tan, Zhijing; Yin, Haidi; Nie, Song; Lin, Zhenxin; Zhu, Jianhui; Ruffin, Mack T; Anderson, Michelle A; Simeone, Diane M; Lubman, David M

    2015-04-03

    Glycosylation has significant effects on protein function and cell metastasis, which are important in cancer progression. It is of great interest to identify site-specific glycosylation in search of potential cancer biomarkers. However, the abundance of glycopeptides is low compared to that of nonglycopeptides after trypsin digestion of serum samples, and the mass spectrometric signals of glycopeptides are often masked by coeluting nonglycopeptides due to low ionization efficiency. Selective enrichment of glycopeptides from complex serum samples is essential for mass spectrometry (MS)-based analysis. Herein, a strategy has been optimized using LCA enrichment to improve the identification of core-fucosylation (CF) sites in serum of pancreatic cancer patients. The optimized strategy was then applied to analyze CF glycopeptide sites in 13 sets of serum samples from pancreatic cancer, chronic pancreatitis, healthy controls, and a standard reference. In total, 630 core-fucosylation sites were identified from 322 CF proteins in pancreatic cancer patient serum using an Orbitrap Elite mass spectrometer. Further data analysis revealed that 8 CF peptides exhibited a significant difference between pancreatic cancer and other controls, which may be potential diagnostic biomarkers for pancreatic cancer.

  13. Standardization of clinical enzyme analysis using frozen human serum pools with values assigned by the International Federation of Clinical Chemistry and Laboratory Medicine reference measurement procedures.

    PubMed

    Tong, Qing; Chen, Baorong; Zhang, Rui; Zuo, Chang

    Variation in clinical enzyme analysis, particularly across different measuring systems and laboratories, represents a critical but long-lasting problem in diagnosis. Calibrators with traceability and commutability are imminently needed to harmonize analysis in laboratory medicine. Fresh frozen human serum pools were assigned values for alanine aminotransferase (ALT), aspartate aminotransferase (AST), gamma-glutamyltransferase (GGT), creatine kinase (CK) and lactate dehydrogenase (LDH) by six laboratories with established International Federation of Clinical Chemistry and Laboratory Medicine reference measurement procedures. These serum pools were then used across 76 laboratories as a calibrator in the analysis of five enzymes. Bias and imprecision in the measurement of the five enzymes tested were significantly reduced by using the value-assigned serum in analytical systems with open and single-point calibration. The median (interquartile range) of the relative biases of ALT, AST, GGT, CK and LDH were 2.0% (0.6-3.4%), 0.8% (-0.8-2.3%), 1.0% (-0.5-2.0%), 0.2% (-0.3-1.0%) and 0.2% (-0.9-1.1%), respectively. Before calibration, the interlaboratory coefficients of variation (CVs) in the analysis of patient serum samples were 8.0-8.2%, 7.3-8.5%, 8.1-8.7%, 5.1-5.9% and 5.8-6.4% for ALT, AST, GGT, CK and LDH, respectively; after calibration, the CVs decreased to 2.7-3.3%, 3.0-3.6%, 1.6-2.1%, 1.8-1.9% and 3.3-3.5%, respectively. The results suggest that the use of fresh frozen serum pools significantly improved the comparability of test results in analytical systems with open and single-point calibration.

  14. Hematology and serum biochemistry of Sumatran rhinoceroses (Dicerorhinus sumatrensis) in a rainforest sanctuary in Way Kambas National Park, Indonesia.

    PubMed

    Andriansyah; Candra, Dedi; Riyanto, Marcellus A C T; Barry, Jason; Radcliffe, Robin W

    2013-06-01

    There is a paucity of basic biological information for the Sumatran rhinoceros (Dicerorhinus sumatrensis). This information is fundamental to husbandry and management practices for captive animals and for support of in situ conservation efforts. Serial blood samples were collected over an 8-yr period to evaluate patterns in hematology and serum biochemistry values among five Sumatran rhinoceroses housed at the Sumatran Rhino Sanctuary in Way Kambas National Park, Lampung, Indonesia. Understanding the basis for variance in analytes both within and between subjects can allow use of more sensitive subject-based reference values, and is particularly suitable for small populations of endangered animals. Both intra- and intersubject variability was computed for each analyte and the associated index of individuality was determined. Previously published cutoff points for index of individuality indicate where population-based reference intervals can be used with confidence (index > 1.4) or with caution (0.6 < index < 1.4). Interrhino variability was small for the majority of analytes, with 12 of 19 analytes having an index of individuality greater than 1.4 and none having an index of individuality less than 0.6. With the high within-individual variability of most anayltes in the Sumatran rhinoceroses at the sanctuary, subject-based reference intervals offer little advantage over standard population-based reference intervals for monitoring the health of these endangered animals. Differences were noted (but not tested for statistical significance) in serum urea, aspartate aminotransferase (AST), lactate dehydrogenase (LDH), and cholesterol between young and old rhinoceroses, and in hematocrit, AST, alanine aminotransferase (ALT), LDH, and glucose between male and female rhinoceroses. Husbandry practices, animal management, nutrition and habitat factors may also impact hematology and biochemistry results, and these relationships deserve more careful investigation. This study represents the most comprehensive hematology and serum biochemistry comparison of Sumatran rhinoceroses held in natural rainforest conditions outside a traditional zoological setting.

  15. Serum thyroid stimulating hormone, total and free T4 during the neonatal period: Establishing regional reference intervals

    PubMed Central

    Sheikhbahaei, Sara; Mahdaviani, Behnaz; Abdollahi, Alireza; Nayeri, Fatemeh

    2014-01-01

    Context: Congenital hypothyroidism (CH), the most common etiology of preventable mental retardation in children, is estimated to be more prevalent among Asian population. Aims: Since thyroid function tests (TFTs) varied among different ages and geographical regions, in this study, the neonatal thyroid reference intervals in a healthy neonatal population is determined for the first time in Iran. Settings and Design: A cross-sectional study performed on 246 healthy term newborns aged between 2 days and 1 month. Materials and Methods: Blood samples were obtained by venipuncture from all subjects. The median, 2.5th, 5th, 95th, and 97.5th percentile of serum thyroid-stimulating hormone (TSH), as well as the total and free T4 were assessed among different age groups. Statistical Analysis Used: Predictive Analytics Software (PASW Statistics 18) was used for the analysis. Results: Serum TSH, total and free T4 concentration peaked in 5th to 7th days of life, continued over 2 weeks, then decreased and started reaching to adult reference range. A significant negative correlation between age and serum concentration of TSH (P = 0.02), total T4 (P = 0.01) and free T4 (P = 0.01) was found. Conclusion: This study yielded fairly different values for TFTs compared compared values found in other countries and also different from values reported for laboratory kits we used. These differences were assumed to be due to variations in ethnicity, age, and laboratory methods used. Due to the lack of international standardization, conducting multicenter studies helps in making a more precise evaluation of thyroid status in neonates. PMID:24701428

  16. Age- and sex-specific reference limits for creatinine, cystatin C and the estimated glomerular filtration rate.

    PubMed

    Hannemann, Anke; Friedrich, Nele; Dittmann, Kathleen; Spielhagen, Christin; Wallaschofski, Henri; Völzke, Henry; Rettig, Rainer; Endlich, Karlhans; Lendeckel, Uwe; Stracke, Sylvia; Nauck, Matthias

    2011-11-14

    Early detection of patients with chronic kidney disease is of great importance. This study developed reference limits for serum creatinine and serum cystatin C concentrations and for the estimated glomerular filtration rate (eGFR) in healthy subjects from the general population aged 25-65 years. This study defined a reference population including 985 subjects from the first follow-up of the Study of Health in Pomerania. Serum creatinine was measured with a modified kinetic Jaffé method. Serum cystatin C was measured with a nephelometric assay. The eGFR was calculated from serum creatinine according to the Cockcroft-Gault (eGFR(CG)) and the Modification of Diet in Renal Disease (eGFR(MDRD)) equation, respectively, as well as from serum cystatin C according to the formula by Larsson (eGFR(Larsson)). Non-parametric quantile regression was used to estimate the reference limits. For serum creatinine and serum cystatin C the 95th percentile and for eGFR(CG), eGFR(MDRD) and eGFR(Larsson) the 5th percentile were selected as reference limits. All data was weighted to reflect the age- and sex-structure of the German population in 2008. The reference limits for serum creatinine (men: 1.11-1.23 mg/dL; women: 0.93-1.00 mg/dL) and serum cystatin C levels (men: 0.92-1.04 mg/L; women: 0.84-1.02 mg/L) increased with advancing age. The reference limits for eGFR decreased with increasing age (eGFR(CG) men: 106.0-64.7 mL/min, women 84.4-57.9 mL/min; eGFR(MDRD) men: 82.5-62.2 mL/min/1.73 m², women 75.0-58.2 mL/min/1.73 m²; eGFR(Larsson) men: 85.5-72.9 mL/min, women 94.5-75.7 mL/min). This study presents age- and sex-specific reference limits for five measures of renal function based on quantile regression models.

  17. Commutability of NIST SRM 1955 Homocysteine and Folate in Frozen Human Serum with selected total homocysteine immunoassays and enzymatic assays.

    PubMed

    Nelson, Bryant C; Pfeiffer, Christine M; Zhang, Ming; Duewer, David L; Sharpless, Katherine E; Lippa, Katrice A

    2008-09-01

    The National Institute of Standards and Technology (NIST) has recently developed Standard Reference Material (SRM) 1955 Homocysteine and Folate in Frozen Human Serum with certified values for total homocysteine (tHcy) and 5-methyl-tetrahydrofolic acid. NIST has performed an international, interlaboratory assessment of SRM 1955 commutability; results are reported for tHcy only. Total Hcy was measured in 20 patient sera and in 3 levels of SRM 1955 using 14 immunoassays and/or enzymatic assays. Liquid chromatography/tandem mass spectrometry was utilized as the reference assay. An "errors-in-variables" statistical model was utilized to assess the commutability of SRM 1955. Normalized residuals ranged from -2.65 to 2.19 for SRM 1955. The median interlaboratory/interassay imprecision (CV) was approximately 4% for patient specimens and ranged from approximately 3% to approximately 7% for SRM 1955. The median intra-assay imprecision ranged from approximately 1% to approximately 13%. Orthogonal residuals, as a descriptor of assay accuracy, ranged from 0.29 to 7.71 and from 0.20 to 2.22 for patient specimens and SRM 1955 samples, respectively. The current study suggests that SRM 1955 is commutable with the investigated tHcy assays; however, a broader specimen set needs to be evaluated to completely substantiate this conclusion.

  18. Serum protein concentrations from clinically healthy horses determined by agarose gel electrophoresis.

    PubMed

    Riond, Barbara; Wenger-Riggenbach, Bettina; Hofmann-Lehmann, Regina; Lutz, Hans

    2009-03-01

    Serum protein electrophoresis is a useful screening test in equine laboratory medicine. The method can provide valuable information about changes in the concentrations of albumin and alpha-, beta-, and gamma-globulins and thereby help characterize dysproteinemias in equine patients. Reference values for horses using agarose gel as a support medium have not been reported. The purpose of this study was to establish reference intervals for serum protein concentrations in adult horses using agarose gel electrophoresis and to assess differences between warm-blooded and heavy draught horses. In addition, the precision of electrophoresis for determining fraction percentages and the detection limit were determined. Blood samples were obtained from 126 clinically healthy horses, including 105 Thoroughbreds and 21 heavy draught horses of both sexes and ranging from 2 to 20 years of age. The total protein concentration was determined by an automated biuret method. Serum protein electrophoresis was performed using a semi-automated agarose gel electrophoresis system. Coefficients of variation (CVs) were calculated for within-run and within-assay precision. Data from warm-blooded and draught horses were compared using the Mann-Whitney U test. Within-run and within-assay CVs were <5% for all protein fractions. No significant difference was found between warm-blooded and heavy draught horses and so combined reference intervals (2.5-97.5%) were calculated for total protein (51.0-72.0 g/L), albumin (29.6-38.5 g/L), alpha(1)-globulin (1.9-3.1 g/L), alpha(2)-globulin (5.3-8.7 g/L), beta(1)-globulin (2.8-7.3g/L), beta(2)-globulin (2.2-6.0 g/L), and gamma-globulin (5.8-12.7 g/L) concentrations, and albumin/globulin ratio (0.93-1.65). Using agarose gel as the supporting matrix for serum protein electrophoresis in horses resulted in excellent resolution and accurate results that facilitated standardization into 6 protein fractions.

  19. Evaluation of four commercial biuret reagent kits of serum total protein by the American Association for Clinical Chemistry reference measurement procedure.

    PubMed

    He, Meilin; Zhang, Jie

    2011-06-01

    In China, the traceability of clinical chemistry methods is still immature. Therefore, it is necessary to establish a reference measurement procedure and evaluate commercial reagent kits using such established procedures. We reproduced the reference measurement procedure for serum total protein, as recommended by the American Association for Clinical Chemistry (AACC). We evaluated the performance by Clinical Laboratory Standard Institute (CLSI) guidelines EP15-A and EP6-A. Subsequently, four commercial reagent kits were evaluated by the reproduced reference procedure following CLSI guideline EP9-A2. The performance of the reproduced reference procedure was as follows: CVs ranged from 0.47% to 0.85% at medical decision levels (X(c)) of 45 g/L, 60 g/L and 80 g/L. Linearity was Y=1.0022X-0.2121 (r=0.9999), and recovery ranged from 100.2% to 102.4%. The External Quality Assessment Scheme for Reference Laboratories in Laboratory Medicine (RELA) was applied, and the result was within the limit of equivalence. The linear relationships of four commercial reagent kits, Merit Choice, KHB, Leadman, and Olympus, were, respectively: Y=0.9922X+0.5776 (r=0.9961); Y=0.9936X+0.4316 (r=0.9992); Y=0.9949X+0.9129 (r=0.9987) and Y=0.9923X+0.8876 (r=0.9989). KHB showed slight negative bias, and the mean±SD was -0.03±0.60 g/L. Merit Choice, Leadman, and Olympus all showed positive bias, and the mean±SDs were 0.02±0.63 g/L, 0.55±0.77 g/L and 0.34±0.71 g/L, respectively. The correlation and bias of four commercial reagent kits for serum total protein were found to be acceptable. Thus, these reagent kits can be used reliably in China.

  20. The standard treatment protocol for paracetamol poisoning may be inadequate following overdose with modified release formulation: a pharmacokinetic and clinical analysis of 53 cases.

    PubMed

    Salmonson, Heléne; Sjöberg, Gunilla; Brogren, Jacob

    2018-01-01

    The use of the standard procedure for managing overdoses with immediate release (IR) paracetamol is questionable when applied to overdoses with modified release (MR) formulations. This study describes the pharmacokinetics of paracetamol and the clinical outcomes following overdoses with a MR formulation. Medical records including laboratory analyses concerning overdoses of MR paracetamol from 2009 to 2015 were collected retrospectively. Inclusion criteria were ingestion of a toxic dose, known time of intake and documented measurements of serum paracetamol and liver function tests. Graphical analysis, descriptive statistics and population pharmacokinetic modelling were used to describe data. Fifty-three cases were identified. Median age was 26 years (range 13-68), median dose was 20 g (range 10-166) and 74% were females. The pharmacokinetic analysis showed a complex, dose dependent serum versus time profile with prolonged absorption and delayed serum peak concentrations with increasing dose. Ten patients had persistently high serum levels for 24 h or more, six of them had a second peak 8-19 h after ingestion. Seven of 34 patients receiving N-acetylcysteine (NAC) within 8 h had alanine aminotransferase (ALT) above reference range. Three of them developed hepatotoxicity (ALT >1000 IU/l). The pharmacokinetic and clinical analysis showed that the standard treatment protocol, including risk assessment and NAC regimen, used for IR paracetamol poisoning not appear suitable for MR formulation. Individual and tailored treatment may be valuable but further studies are warranted to determine optimal regimen of overdoses with MR formulation.

  1. Reference intervals for selected serum biochemistry analytes in cheetahs Acinonyx jubatus.

    PubMed

    Hudson-Lamb, Gavin C; Schoeman, Johan P; Hooijberg, Emma H; Heinrich, Sonja K; Tordiffe, Adrian S W

    2016-02-26

    Published haematologic and serum biochemistry reference intervals are very scarce for captive cheetahs and even more for free-ranging cheetahs. The current study was performed to establish reference intervals for selected serum biochemistry analytes in cheetahs. Baseline serum biochemistry analytes were analysed from 66 healthy Namibian cheetahs. Samples were collected from 30 captive cheetahs at the AfriCat Foundation and 36 free-ranging cheetahs from central Namibia. The effects of captivity-status, age, sex and haemolysis score on the tested serum analytes were investigated. The biochemistry analytes that were measured were sodium, potassium, magnesium, chloride, urea and creatinine. The 90% confidence interval of the reference limits was obtained using the non-parametric bootstrap method. Reference intervals were preferentially determined by the non-parametric method and were as follows: sodium (128 mmol/L - 166 mmol/L), potassium (3.9 mmol/L - 5.2 mmol/L), magnesium (0.8 mmol/L - 1.2 mmol/L), chloride (97 mmol/L - 130 mmol/L), urea (8.2 mmol/L - 25.1 mmol/L) and creatinine (88 µmol/L - 288 µmol/L). Reference intervals from the current study were compared with International Species Information System values for cheetahs and found to be narrower. Moreover, age, sex and haemolysis score had no significant effect on the serum analytes in this study. Separate reference intervals for captive and free-ranging cheetahs were also determined. Captive cheetahs had higher urea values, most likely due to dietary factors. This study is the first to establish reference intervals for serum biochemistry analytes in cheetahs according to international guidelines. These results can be used for future health and disease assessments in both captive and free-ranging cheetahs.

  2. Serum proteins by capillary zone electrophoresis: approaches to the definition of reference values.

    PubMed

    Petrini, C; Alessio, M G; Scapellato, L; Brambilla, S; Franzini, C

    1999-10-01

    The Paragon CZE 2000 (Beckman Analytical, Milan, Italy) is an automatic dedicated capillary zone electrophoresis (CZE) system, producing a five-zone serum protein pattern with quantitative estimation of the zones. With the view of substituting this instrument for two previously used serum protein electrophoresis techniques, we planned to produce reference values for the "new" systems leading to compatible interpretation of the results. High resolution cellulose acetate electrophoresis with visual inspection and descriptive reporting (HR-CAE) and five-zone cellulose acetate electrophoresis with densitometry (CAE-D) were the previously used techniques. Serum samples (n = 167) giving "normal pattern" with HR-CAE were assayed with the CZE system, and the results were statistically assessed to yield 0.95 reference intervals. One thousand normal and pathological serum samples were then assayed with the CAE-D and the CZE techniques, and the regression equations of the CAE-D values over the CZE values for the five zones were used to transform the CAE-D reference limits into the CZE reference limits. The two sets of reference values thereby produced were in good agreement with each other and also with reference values previously reported for the CZE system. Thus, reference values for the CZE techniques permit interpretation of results coherent with the previously used techniques and reporting modes.

  3. Comparison of serum serotonin and serum 5-HIAA LC-MS/MS assays in the diagnosis of serotonin producing neuroendocrine neoplasms: A pilot study.

    PubMed

    Lindström, Mikael; Tohmola, Niina; Renkonen, Risto; Hämäläinen, Esa; Schalin-Jäntti, Camilla; Itkonen, Outi

    2018-07-01

    Serotonin (5-hydroxytyramine) is a mediator of gastrointestinal smooth muscle contraction, and is secreted by neuroendocrine neoplasms (NENs). We developed a liquid chromatography tandem mass spectrometry (LC-MS/MS) assay for serum serotonin to be used in NEN diagnostics and follow-up. We used serum samples from healthy volunteers (n = 31) and patients suspected or monitored for NEN (n = 98). Serotonin-D 4 internal standard was added to samples before solid phase extraction (SPE) and quantification by LC-MS/MS. The effects of sample handling and preparation on serotonin stability were studied. Finally, we established a provisional reference range for serum serotonin and compared our assay with serum 5-hydroxyindoleacetic acid (5-HIAA) for detection of NENs. Our assay is sensitive and has a wide linear range (10-10,000 nmol/l). Serum serotonin is stable for 7 days at room temperature and for 3 months at -20 °C. Sampling temperature is not critical. Normal range for serum serotonin was 270-1490 nmol/l. We found that serum serotonin and 5-HIAA performed equally well as diagnostic tests for NENs. Our LC-MS/MS assay for serum serotonin is well suited for clinical research and patient diagnostics. Our results confirm that it can complement 5-HIAA in diagnosis of NENs. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. Use of cerebrospinal fluid and serum samples impregnated on FTATM Elute filter paper for the diagnosis of infections caused by Neisseria meningitidis, Streptococcus pneumoniae and Haemophilus influenzae

    PubMed Central

    Gonçalves, Maria Gisele; Higa, Fábio Takenori; Castilho, Euclides Ayres; Ibarz-Pavón, Ana Belén; Sacchi, Claudio Tavares

    2017-01-01

    Background The lack of information regarding the burden of acute bacterial meningitis in Latin America leads to a reduction in the estimated incidence rates of the disease, and impairs public health decisions on the use and follow-up of preventive interventions, particularly, the evaluation of existing vaccination policies. The use of the real-time PCR in diagnostic routine procedures has resulted in a substantial increase in confirmed bacterial meningitis cases. However, in resource-poor countries, these assays are only available in reference laboratories. Sample transportation to these laboratories is a critical constraint, as it requires specialized, high cost courier services. To overcome this barrier we evaluated the use of FTATM Elute filter paper cards for the conservation and processing of samples under normal environmental conditions, as they would be when transported from remote and under-equipped healthcare facilities to the reference centers. A total of 401 samples received in 2015 as part of Sao Paulo’s national surveillance for routine diagnosis were selected for this study. Methods The sensitivity and specificity of real-time PCR were evaluated using fresh serum and cerebrospinal fluid (CSF) samples processed using our laboratory’s standard DNA extraction, and processing the same samples after being dried and stored on FTATM card, and DNA extracted following the manufacturer’s instructions. Results The sensitivities for detection of Neisseria meningitidis, Streptococcus pneumoniae, and Haemophilus influenzae from CSF dried and stored on FTATM cards were 98%, 92%, and 100%, respectively, and with serum samples were 73%, 88%, and 100%, respectively. When compared to our laboratory’s standard methodology, results showed high concordance, with Kappa index ranges of 0.9877–1.00 for CSF, and 0.8004–1.00 for serum samples. Conclusion The use of FTATM cards for CSF and serum conservation and transport represents a rapid, reliable, and cost-effective alternative that will allow obtaining valuable epidemiological information that would otherwise be lost. PMID:28235065

  5. Micronutrient deficiency in obese subjects undergoing low calorie diet

    PubMed Central

    2012-01-01

    Background The prevalence of micronutrient deficiencies is higher in obese individuals compared to normal-weight people, probably because of inadequate eating habits but also due to increased demands among overweight persons, which are underestimated by dietary reference intakes (DRI) intended for the general population. We therefore evaluated the dietary micronutrient intake in obese individuals compared to a reference population and DRI recommendations. Furthermore, we determined the micronutrient status in obese subjects undergoing a standardized DRI-covering low-calorie formula diet to analyze if the DRI meet the micronutrient requirements of obese individuals. Methods In 104 subjects baseline micronutrient intake was determined by dietary record collection. A randomly assigned subgroup of subjects (n = 32) underwent a standardized DRI-covering low-calorie formula diet over a period of three months. Pre- and post-interventional intracellular micronutrient status in buccal mucosa cells (BMC) was analyzed, as well as additional micronutrient serum concentrations in 14 of the subjects. Results Prior to dietetic intervention, nutrition was calorie-rich and micronutrient-poor. Baseline deficiencies in serum concentrations were observed for 25-hydroxyvitamin-D, vitamin C, selenium, iron, as well as ß-carotene, vitamin C, and lycopene in BMC. After a three-month period of formula diet even more subjects had reduced micronutrient levels of vitamin C (serum, BMC), zinc, and lycopene. There was a significant negative correlation between lipophilic serum vitamin concentrations and body fat, as well as between iron and C-reactive protein. Conclusions The present pilot study shows that micronutrient deficiency occurring in obese individuals is not corrected by protein-rich formula diet containing vitamins and minerals according to DRI. In contrast, micronutrient levels remain low or become even lower, which might be explained by insufficient intake, increased demand and unbalanced dispersal of lipophilic compounds in the body. Trial registration The study was registered at ClinicalTrials.gov (NCT01344525). The study protocol comprises only a part of the approved trial protocol. PMID:22657586

  6. Evaluation of a CLEIA automated assay system for the detection of a panel of tumor markers.

    PubMed

    Falzarano, Renato; Viggiani, Valentina; Michienzi, Simona; Longo, Flavia; Tudini, Silvestra; Frati, Luigi; Anastasi, Emanuela

    2013-10-01

    Tumor markers are commonly used to detect a relapse of disease in oncologic patients during follow-up. It is important to evaluate new assay systems for a better and more precise assessment, as a standardized method is currently lacking. The aim of this study was to assess the concordance between an automated chemiluminescent enzyme immunoassay system (LUMIPULSE® G1200) and our reference methods using seven tumor markers. Serum samples from 787 subjects representing a variety of diagnoses, including oncologic, were analyzed using LUMIPULSE® G1200 and our reference methods. Serum values were measured for the following analytes: prostate-specific antigen (PSA), alpha-fetoprotein (AFP), carcinoembryonic antigen (CEA), cancer antigen 125 (CA125), carbohydrate antigen 15-3 (CA15-3), carbohydrate antigen 19-9 (CA19-9), and cytokeratin 19 fragment (CYFRA 21-1). For the determination of CEA, AFP, and PSA, an automatic analyzer based on chemiluminescence was applied as reference method. To assess CYFRA 21-1, CA125, CA19-9, and CA15-3, an immunoradiometric manual system was employed. Method comparison by Passing-Bablok analysis resulted in slopes ranging from 0.9728 to 1.9089 and correlation coefficients from 0.9977 to 0.9335. The precision of each assay was assessed by testing six serum samples. Each sample was analyzed for all tumor biomarkers in duplicate and in three different runs. The coefficients of variation were less than 6.3 and 6.2 % for within-run and between-run variation, respectively. Our data suggest an overall good interassay agreement for all markers. The comparison with our reference methods showed good precision and reliability, highlighting its usefulness in clinical laboratory's routine.

  7. Serum fructosamine concentrations in dogs with hypothyroidism.

    PubMed

    Reusch, C E; Gerber, B; Boretti, F S

    2002-10-01

    Serum fructosamine concentrations were measured in 11 untreated hypothyroid dogs with normal serum glucose and serum protein concentrations. The fructosamine level ranged between 276 and 441 micromol/L (median 376 micromol/L; reference range 207-340 micromol/L). Nine of the 11 dogs had fructosamine levels above the reference range. The fructosamine levels decreased significantly during treatment with levothyroxine. It is suggested that serum fructosamine concentrations may be high in hypothyroid dogs because of decelerated protein turnover, independent of the blood glucose concentration.

  8. New radioimmunoassay for follicle-stimulating hormone in macaques: ovulatory menstrual cycles. [/sup 125/I tracer technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hodgen, G.D.; Wilks, J.W.; Vaitukaitis, J.L.

    A sensitive and specific radioimmunoassay system for macaque follicle-stimulating hormone (mFSH) was developed utilizing an antiserum (H-31) prepared in a rabbit against purified ovine FSH as the immunogen. Sera from castrated female, adult male, and juvenile rhesus monkeys, as well as urinary extracts from castrated rhesus and bonnet monkeys, were used to demonstrate parallelism with a standard of partially purified monkey pituitary gonadotropins (LER-M-907-D). An extract of baboon pituitary tissue also showed parallelism with the reference standard. A highly purified pituitary extract (WP-X-105-28), containing approximately 75 percent macaque luteinizing hormone (mLH) and 1 percent mFSH, was used to demonstrate themore » specificity of this mFSH assay system. Sera and urinary extracts obtained from hypophysectomized monkeys did not show cross-reactivity in the assay. Macaque chorionic gonadotropin (mCG) did not produce an inhibition curve in the assay, as determined from serum samples and urinary extracts collected from pregnant monkeys at the time of peak mCG secretion. Serum concentrations of mFSH were suppressed in ovariectomized monkeys by the administration of ethinyl estradiol for 3 days, but returned to near pretreatment values by 96 h after the last estradiol administration. The determination of serum mFSH concentrations in daily blood samples obtained from 20 rhesus monkeys throughout ovulatory menstrual cycles revealed a pattern similar to that previously reported for the rhesus monkey and the woman. The peak value of serum mFSH during the menstrual cycle coincided with the midcycle surge of mLH in each case. The gonadotropin peaks were preceded by increasing serum concentrations of estradiol and followed by rises in the serum concentrations of progesterone.« less

  9. Maternal Exposure to Bisphenol-A and Fetal Growth Restriction: A Case-Referent Study

    PubMed Central

    Burstyn, Igor; Martin, Jonathan W.; Beesoon, Sanjay; Bamforth, Fiona; Li, Qiaozhi; Yasui, Yutaka; Cherry, Nicola M.

    2013-01-01

    We conducted a case-referent study of the effect of exposure to bisphenol-A on fetal growth in utero in full-term, live-born singletons in Alberta, Canada. Newborns <10 percentile of expected weight for gestational age and sex were individually matched on sex, maternal smoking and maternal age to referents with weight appropriate to gestational age. Exposure of the fetus to bisphenol-A was estimated from maternal serum collected at 15–16 weeks of gestation. We pooled sera across subjects for exposure assessment, stratified on case-referent status and sex. Individual 1:1 matching was maintained in assembling 69 case and 69 referent pools created from 550 case-referent pairs. Matched pools had an equal number of aliquots from individual women. We used an analytical strategy conditioning on matched set and total pool-level values of covariates to estimate individual-level effects. Pools of cases and referents had identical geometric mean bisphenol-A concentrations (0.5 ng/mL) and similar geometric standard deviations (2.3–2.5). Mean difference in concentration between matched pools was 0 ng/mL, standard deviation: 1 ng/mL. Stratification by sex and control for confounding did not suggest bisphenol-A increased fetal growth restriction. Our analysis does not provide evidence to support the hypothesis that bisphenol-A contributes to fetal growth restriction in full-term singletons. PMID:24336026

  10. Serum PCB levels and congener profiles among teachers in PCB-containing schools: a pilot study

    PubMed Central

    2011-01-01

    Background PCB contamination in the built environment may result from the release of PCBs from building materials. The significance of this contamination as a pathway of human exposure is not well-characterized, however. This research compared the serum PCB concentrations, and congener profiles between 18 teachers in PCB-containing schools and referent populations. Methods Blood samples from 18 teachers in PCB-containing schools were analyzed for 57 PCB congeners. Serum PCB concentrations and congener patterns were compared between the teachers, to the 2003-4 NHANES (National Health and Nutrition Examination Survey) data, and to data from 358 Greater Boston area men. Results Teachers at one school had higher levels of lighter (PCB 6-74) congeners compared to teachers from other schools. PCB congener 47 contributed substantially to these elevated levels. Older teachers (ages 50-64) from all schools had higher total (sum of 33 congeners) serum PCB concentrations than age-comparable NHANES reference values. Comparing the teachers to the referent population of men from the Greater Boston area (all under age 51), no difference in total serum PCB levels was observed between the referents and teachers up to 50 years age. However, the teachers had significantly elevated serum concentrations of lighter congeners (PCB 6-74). This difference was confirmed by comparing the congener-specific ratios between groups, and principal component analysis showed that the relative contribution of lighter congeners differed between the teachers and the referents. Conclusions These findings suggest that the teachers in the PCB-containing buildings had higher serum levels of lighter PCB congeners (PCB 6-74) than the referent populations. Examination of the patterns, as well as concentrations of individual PCB congeners in serum is essential to investigating the contributions from potential environmental sources of PCB exposure. PMID:21668970

  11. Investigational study of tamoxifen phase I metabolites using chromatographic and spectroscopic analytical techniques.

    PubMed

    Teunissen, S F; Rosing, H; Seoane, M Dominguez; Brunsveld, L; Schellens, J H M; Schinkel, A H; Beijnen, J H

    2011-06-01

    A comprehensive overview is presented of currently known phase I metabolites of tamoxifen consisting of their systematic name and molecular structure. Reference standards are utilized to elucidate the MS(n) fragmentation patterns of these metabolites using a linear ion trap mass spectrometer. UV-absorption spectra are recorded and absorption maxima are defined. Serum extracts from ten breast cancer patients receiving 40mg tamoxifen once daily were qualitatively analyzed for tamoxifen phase I metabolites using a liquid chromatography-tandem mass spectrometry set-up. In total, 19 metabolites have been identified in these serum samples. Additionally a synthetic method for the preparation of the putative metabolite 3',4'-dihydroxytamoxifen is described. Copyright © 2011 Elsevier B.V. All rights reserved.

  12. Simultaneous measurement of total estradiol and testosterone in human serum by isotope dilution liquid chromatography tandem mass spectrometry.

    PubMed

    Zhou, Hui; Wang, Yuesong; Gatcombe, Matthew; Farris, Jacob; Botelho, Julianne C; Caudill, Samuel P; Vesper, Hubert W

    2017-10-01

    Reliable measurement of total testosterone and estradiol is critical for their use as biomarkers of hormone-related disorders in patient care and translational research. We developed and validated a mass spectrometry method to simultaneously quantify these analytes in human serum without chemical derivatization. Serum is equilibrated with isotopic internal standards and treated with acidic buffer to release hormones from their binding proteins. Lipids are isolated and polar impurities are removed by two serial liquid-liquid extraction steps. Total testosterone and estradiol are measured using liquid chromatography tandem mass spectrometry (LC-MS/MS) in combination of positive and negative electrospray ionization modes. The method shows broad analytical measurement range for both testosterone 0.03-48.5 nM (0.75-1400 ng/dL) and estradiol 11.0-5138 pM (2.99-1400 pg/mL) and excellent agreement with certified reference materials (mean bias less than 2.1% to SRM 971, BCR 576, 577, and 578) and a high order reference method (mean bias 1.25% for testosterone and -0.84% for estradiol). The high accuracy of the method was monitored and certified by CDC Hormone Standardization (HoSt) Program for 2 years with mean bias -0.7% (95% CI -1.6% to 0.2%) for testosterone and 0.1% (95% CI -2.2% to 2.3%) for estradiol. The method precision over a 2-year period for quality control pools at low, medium, and high concentrations was 2.7-2.9% for testosterone and 3.3-5.3% for estradiol. With the consistently excellent accuracy and precision, this method is readily applicable for high-throughput clinical and epidemiological studies.

  13. Simultaneous measurement of total Estradiol and Testosterone in human serum by isotope dilution liquid chromatography tandem mass spectrometry

    PubMed Central

    Zhou, Hui; Wang, Yuesong; Gatcombe, Matthew; Farris, Jacob; Botelho, Julianne C.; Caudill, Samuel P.; Vesper, Hubert W.

    2017-01-01

    Reliable measurement of total testosterone and estradiol is critical for their use as biomarkers of hormone related disorders in patient care and translation research. We developed and validated a mass spectrometry method to simultaneously quantify these analytes in human serum without chemical derivatization. Serum is equilibrated with isotopic internal standards and treated with acidic buffer to release hormones from their binding proteins. Lipids are isolated and polar impurities are removed by two serial liquid-liquid extraction steps. Total testosterone and estradiol are measured using liquid chromatography tandem mass spectrometry (LC-MS/MS) in combination of positive and negative electrospray ionization modes. The method shows broad analytical measurement range for both testosterone 0.03–48.5 nM (0.75–1400 ng/dL) and estradiol 11.0–5138 pM (2.99–1400 pg/mL) and excellent agreement with certified reference materials (mean bias less than 2.1% to SRM 971, BCR 576, 577, and 578) and a high order reference method (mean bias 1.25% for testosterone and −0.84% for estradiol). The high accuracy of the method was monitored and certified by CDC Hormone Standardization (HoSt) Program for two years with mean bias −0.7% (95%CI: −1.6% to 0.2%) for testosterone and 0.1% (95%CI: −2.2% to 2.3%) for estradiol. The method precision over a 2-year period for Quality Control pools at low, medium and high concentrations was 2.7–2.9% for testosterone and 3.3–5.3% for estradiol. With the consistently excellent accuracy and precision, this method is readily applicable for high-throughput clinical and epidemiological studies. PMID:28801832

  14. Evaluation of two 4th generation point-of-care assays for the detection of Human Immunodeficiency Virus infection.

    PubMed

    Stafylis, Chrysovalantis; Klausner, Jeffrey D

    2017-01-01

    Fourth generation assays detect simultaneously antibodies for HIV and the p24 antigen, identifying HIV infection earlier than previous generation tests. Previous studies have shown that the Alere Determine HIV-1/2 Combo has lower than anticipated performance in detecting antibodies for HIV and the p24 antigen. Furthermore, there are currently very few studies evaluating the performance of Standard Diagnostics BIOLINE HIV Ag/Ab Combo. To evaluate the performance of the Alere Determine HIV-1/2 Combo and the Standard Diagnostics BIOLINE HIV Ag/Ab Combo in a panel of frozen serum samples. The testing panel included 133 previously frozen serum specimens from the UCLA Clinical Microbiology & Immunoserology laboratory. Reference testing included testing for HIV antibodies by a 3rd generation enzyme immunoassay followed by HIV RNA detection. Antibody negative and RNA positive sera were also tested by a laboratory 4th generation HIV Ab/Ag enzyme immunoassay. Reference testing yielded 97 positives for HIV infection and 36 negative samples. Sensitivity of the Alere test was 95% (88-98%), while the SD Bioline sensitivity was 91% (83-96%). Both assays showed 100% (90-100%) specificity. No indeterminate or invalid results were recorded. Among 13 samples with acute infection (HIV RNA positive, HIV antibody negative), 12 were found positive by the first assay and 8 by the second. The antigen component of the Alere assay detected 10 acute samples, while the SD Bioline assay detected only one. Both rapid assays showed very good overall performance in detecting HIV infection in frozen serum samples, but further improvements are required to improve the performance in acute infection.

  15. Comparing age-wise reference intervals for serum creatinine concentration in a "Reality check" of the recommended cut-off.

    PubMed

    Verma, Mascha; Khadapkar, Rashmi; Sahu, Priyadarshi Soumyaranjan; Das, Bibhu Ranjan

    2006-09-01

    An increase in the communication within the healthcare services, both nationally and internationally, has strengthened the need for harmonization of measurements and reference intervals in laboratory medicine. In the present report, the calculated reference interval for serum creatinine (sCr) levels of healthy normal individuals (n=1121) in different sex and age groups are compared with the established interval. The calculated reference interval for sCr level was 0.4-1.3 mg/dL and 0.6 to 1.3 mg/dL in the age groups of 21-40 and 41-60 years respectively. The difference between the mean sCr values in total males and total females (age range 21-60 years) was statistically significant (p<0.0001); When male and female subjects were analyzed age-group wise, the data showed a significant difference in mean sCr values (p<0.0001) in three age groups (21-30, 31-40 and 41-50 years) however, in older age group (51-60 years), the difference was non-significant (p=0.07). The reference ranges were 0.7-1.3 and 0.4-1.0 mg/dL for males and females respectively where the lower limit was 0.1-0.2 units less than that of standard limits. An increase in the mean value of sCr was observed particularly in females with an increase in age. Hence it is of interest to validate an age specific reference ranges for sCr in our population.

  16. An echocardiographic study of healthy Border Collies with normal reference ranges for the breed.

    PubMed

    Jacobson, Jake H; Boon, June A; Bright, Janice M

    2013-06-01

    The objectives of this study were to obtain standard echocardiographic measurements from healthy Border Collies and to compare these measurements to those previously reported for a general population of dogs. Standard echocardiographic data were obtained from twenty apparently healthy Border Collie dogs. These data (n = 20) were compared to data obtained from a general population of healthy dogs (n = 69). Border Collies were deemed healthy based on normal history, physical examination, complete blood count, serum biochemical profile, electrocardiogram, and blood pressure, with no evidence of congenital or acquired heart disease on echocardiographic examination. Standard two dimensional, M-mode, and Doppler echocardiographic measurements were obtained and normal ranges determined. The data were compared to data previously obtained at our hospital from a general population of normal dogs. Two dimensional, M-mode, and Doppler reference ranges for healthy Border Collies are presented in tabular form. Comparison of the weight adjusted M-mode echocardiographic means from Border Collies to those from the general population of dogs showed Border Collies to have larger left ventricular systolic and diastolic dimensions, smaller interventricular septal thickness, and lower fractional shortening. There are differences in some echocardiographic parameters between healthy Border Collies and the general dog population, and the echocardiographic reference ranges provided in this study should be used as breed specific reference values for Border Collies. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Serum albumin: accuracy and clinical use.

    PubMed

    Infusino, Ilenia; Panteghini, Mauro

    2013-04-18

    Albumin is the major plasma protein and its determination is used for the prognostic assessment of several diseases. Clinical guidelines call for monitoring of serum albumin with specific target cut-offs that are independent of the assay used. This requires accurate and equivalent results among different commercially available methods (i.e., result standardization) through a consistent definition and application of a reference measurement system. This should be associated with the definition of measurement uncertainty goals based on medical relevance of serum albumin to make results reliable for patient management. In this paper, we show that, in the current situation, if one applies analytical goals for serum albumin measurement derived from its biologic variation, the uncertainty budget derived from each step of the albumin traceability chain is probably too high to fulfil established quality levels for albumin measurement and to guarantee the accuracy needed for clinical usefulness of the test. The situation is further worsened if non-specific colorimetric methods are used for albumin measurement as they represent an additional random source of uncertainty. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. Analysis of some chosen elements of cerebrospinal fluid and serum in amyotrophic lateral sclerosis patients by total reflection X-ray fluorescence

    NASA Astrophysics Data System (ADS)

    Ostachowicz, B.; Lankosz, M.; Tomik, B.; Adamek, D.; Wobrauschek, P.; Streli, C.; Kregsamer, P.

    2006-11-01

    Trace elements play an important role in the human central nervous system. Significant variations of the concentration of trace elements in body fluids may occur in neurodegenerative diseases. In the present work an investigation of the elemental composition of the serum, and the cerebrospinal fluid in amyotrophic lateral sclerosis patients and a control group was performed. For the analysis of the body fluids Total reflection X-ray Fluorescence (TXRF) spectrometry was used. The samples were taken during routine diagnostic procedures. Na, Mg, Cl, K, Ca, Cu, Zn, and Br were determined in both fluids. In order to validate the results of analysis a serum standard reference material was measured. A t-test was applied to check if the mean concentrations of the elements are different for ALS and the control group. For the serum samples higher values for Br were found in the ALS group, for the cerebrospinal fluid lower values of Na, Mg and Zn as well as higher Ca values were found in the ALS group compared to the control group.

  19. Analytical Bias Exceeding Desirable Quality Goal in 4 out of 5 Common Immunoassays: Results of a Native Single Serum Sample External Quality Assessment Program for Cobalamin, Folate, Ferritin, Thyroid-Stimulating Hormone, and Free T4 Analyses.

    PubMed

    Kristensen, Gunn B B; Rustad, Pål; Berg, Jens P; Aakre, Kristin M

    2016-09-01

    We undertook this study to evaluate method differences for 5 components analyzed by immunoassays, to explore whether the use of method-dependent reference intervals may compensate for method differences, and to investigate commutability of external quality assessment (EQA) materials. Twenty fresh native single serum samples, a fresh native serum pool, Nordic Federation of Clinical Chemistry Reference Serum X (serum X) (serum pool), and 2 EQA materials were sent to 38 laboratories for measurement of cobalamin, folate, ferritin, free T4, and thyroid-stimulating hormone (TSH) by 5 different measurement procedures [Roche Cobas (n = 15), Roche Modular (n = 4), Abbott Architect (n = 8), Beckman Coulter Unicel (n = 2), and Siemens ADVIA Centaur (n = 9)]. The target value for each component was calculated based on the mean of method means or measured by a reference measurement procedure (free T4). Quality specifications were based on biological variation. Local reference intervals were reported from all laboratories. Method differences that exceeded acceptable bias were found for all components except folate. Free T4 differences from the uncommonly used reference measurement procedure were large. Reference intervals differed between measurement procedures but also within 1 measurement procedure. The serum X material was commutable for all components and measurement procedures, whereas the EQA materials were noncommutable in 13 of 50 occasions (5 components, 5 methods, 2 EQA materials). The bias between the measurement procedures was unacceptably large in 4/5 tested components. Traceability to reference materials as claimed by the manufacturers did not lead to acceptable harmonization. Adjustment of reference intervals in accordance with method differences and use of commutable EQA samples are not implemented commonly. © 2016 American Association for Clinical Chemistry.

  20. Reference Values of 14 Serum Trace Elements for Pregnant Chinese Women: A Cross-Sectional Study in the China Nutrition and Health Survey 2010-2012.

    PubMed

    Liu, Xiaobing; Zhang, Yu; Piao, Jianhua; Mao, Deqian; Li, Yajie; Li, Weidong; Yang, Lichen; Yang, Xiaoguang

    2017-03-21

    The development of reference values of trace elements is recognized as a fundamental prerequisite for the assessment of trace element nutritional status and health risks. In this study, a total of 1400 pregnant women aged 27.0 ± 4.5 years were randomly selected from the China Nutrition and Health Survey 2010-2012 (CNHS 2010-2012). The concentrations of 14 serum trace elements were determined by high-resolution inductively coupled plasma mass spectrometry. Reference values were calculated covering the central 95% reference intervals (P2.5-P97.5) after excluding outliers by Dixon's test. The overall reference values of serum trace elements were 131.5 (55.8-265.0 μg/dL for iron (Fe), 195.5 (107.0-362.4) μg/dL for copper (Cu), 74.0 (51.8-111.3) μg/dL for zinc (Zn), 22.3 (14.0-62.0) μg/dL for rubidium (Rb), 72.2 (39.9-111.6) μg/L for selenium (Se), 45.9 (23.8-104.3) μg/L for strontium (Sr), 1.8 (1.2-3.6) μg/L for molybdenum (Mo), 2.4 (1.2-8.4) μg/L for manganese (Mn), 1.9 (0.6-9.0) ng/L for lead (Pb), 1.1 (0.3-5.6) ng/L for arsenic (As), 835.6 (219.8-4287.7) ng/L for chromium (Cr), 337.9 (57.0-1130.0) ng/L for cobalt (Co), 193.2 (23.6-2323.1) ng/L for vanadium (V), and 133.7 (72.1-595.1) ng/L for cadmium (Cd). Furthermore, some significant differences in serum trace element reference values were observed between different groupings of age intervals, residences, anthropometric status, and duration of pregnancy. We found that serum Fe, Zn, and Se concentrations significantly decreased, whereas serum Cu, Sr, and Co concentrations elevated progressively compared with reference values of 14 serum trace elements in pregnant Chinese women. The reference values of serum trace elements established could play a key role in the following nutritional status and health risk assessment.

  1. CLSI-based transference and verification of CALIPER pediatric reference intervals for 29 Ortho VITROS 5600 chemistry assays.

    PubMed

    Higgins, Victoria; Truong, Dorothy; Woroch, Amy; Chan, Man Khun; Tahmasebi, Houman; Adeli, Khosrow

    2018-03-01

    Evidence-based reference intervals (RIs) are essential to accurately interpret pediatric laboratory test results. To fill gaps in pediatric RIs, the Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER) project developed an age- and sex-specific pediatric RI database based on healthy pediatric subjects. Originally established for Abbott ARCHITECT assays, CALIPER RIs were transferred to assays on Beckman, Roche, Siemens, and Ortho analytical platforms. This study provides transferred reference intervals for 29 biochemical assays for the Ortho VITROS 5600 Chemistry System (Ortho). Based on Clinical Laboratory Standards Institute (CLSI) guidelines, a method comparison analysis was performed by measuring approximately 200 patient serum samples using Abbott and Ortho assays. The equation of the line of best fit was calculated and the appropriateness of the linear model was assessed. This equation was used to transfer RIs from Abbott to Ortho assays. Transferred RIs were verified using 84 healthy pediatric serum samples from the CALIPER cohort. RIs for most chemistry analytes successfully transferred from Abbott to Ortho assays. Calcium and CO 2 did not meet statistical criteria for transference (r 2 <0.70). Of the 32 transferred reference intervals, 29 successfully verified with approximately 90% of results from reference samples falling within transferred confidence limits. Transferred RIs for total bilirubin, magnesium, and LDH did not meet verification criteria and are not reported. This study broadens the utility of the CALIPER pediatric RI database to laboratories using Ortho VITROS 5600 biochemical assays. Clinical laboratories should verify CALIPER reference intervals for their specific analytical platform and local population as recommended by CLSI. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  2. Performance of Commercial Enzyme-Linked Immunosorbent Assays for Detection of Antibodies to Bordetella pertussis▿

    PubMed Central

    Riffelmann, M.; Thiel, K.; Schmetz, J.; Wirsing von Koenig, C. H.

    2010-01-01

    Measuring antibodies to Bordetella pertussis antigens is mostly done by enzyme-linked immunosorbent assays (ELISAs). We compared the performance of ELISA kits that were commercially available in Germany. Eleven measured IgG antibodies, and nine measured IgA antibodies. An in-house ELISA with purified antigens served as a reference method. Samples included two WHO reference preparations, the former Food and Drug Administration (FDA)/Center for Biologics Evaluation and Research (CBER) reference preparations, serum samples from patients with clinically suspected pertussis, and serum samples from patients having received a combined tetanus, diphtheria, and pertussis (Tdap) vaccination. Kits using pertussis toxin (PT) as an antigen showed linearity compared to the WHO Reference preparation (r2 between 0.82 and 0.99), and these kits could quantify antibodies according to the reference preparation. ELISA kits using mixed antigens showed no linear correlation to the reference preparations. Patient results were compared to results of in-house ELISAs using a dual cutoff of either ≥100 IU/ml anti-PT IgG or ≥40 IU/ml anti-PT IgG together with ≥12 IU/ml anti-PT IgA. The sensitivities of kits measuring IgG antibodies ranged between 0.84 and 1.00. The specificities of kits using PT as an antigen were between 0.81 and 0.93. The specificities of kits using mixed antigens were between 0.51 and 0.59 and were thus not acceptable. The sensitivities of kits measuring IgA antibodies ranged between 0.53 and 0.73, and the specificities were between 0.67 and 0.94, indicating that IgA antibodies may be of limited diagnostic value. Our data suggest that ELISAs should use purified PT as an antigen and be standardized to the 1st International Reference preparation. PMID:20943873

  3. Hematologic and serum biochemistry reference values in wild-caught white-footed tamarins (Saguinus leucopus) housed in captivity.

    PubMed

    Fox, Maureen; Brieva, Claudia; Moreno, Carlos; MacWilliams, Peter; Thomas, Chet

    2008-12-01

    The white-footed tamarin (Saguinus leucopus) is an endangered primate that lives in a small forest corridor in northern Colombia, South America. Hematologic and serum biochemistry reference values are important tools in evaluating the health of the white-footed tamarin and serve to promote the survival of this species. The purpose of this study was to establish diagnostically important hematologic and serum biochemistry reference values for healthy white-footed tamarins and to determine whether there was significant variation with respect to age class (juveniles, adults), gender, and housing facility. Blood samples were collected for hematologic and serum biochemistry measurements from 29 wild-caught captive tamarins during February and April 2005, housed at three different facilities in central Colombia. Hematology and serum biochemistry values were similar in adults and juveniles. Female white-footed tamarins had absolute reticulocyte counts that were lower than those of male tamarins and males had lower serum chloride concentrations than female tamarins. Mean values for hemoglobin, mean cell hemoglobin, serum total protein, albumin, glucose, and alkaline phosphatase varied among the three housing facilities. Twenty-two of the 29 tamarins sampled were microfilaria-positive and had significantly higher mean serum alkaline phosphatase concentrations. Among the 29 tamarins sampled in this study, serum values for mean alkaline phosphatase and creatine kinase concentrations were higher than reported values for other mammals. The reference intervals determined in this study were comparable to normal ranges reported for other members of the family Callitrichidae.

  4. Performance of prenatal screening using maternal serum and ultrasound markers for Down syndrome in Chinese women: a systematic review and meta-analysis.

    PubMed

    Tu, S; Rosenthal, M; Wang, D; Huang, J; Chen, Y

    2016-09-01

    Controversies about the performance of conventional prenatal screening using maternal serum and ultrasound markers (PSMSUM) in detecting Down syndrome (DS) have been raised as a result of a recently available noninvasive prenatal test based on cell-free fetal DNA sequencing. To evaluate the screening performance of PSMSUM in detecting DS in Chinese women. An exhaustive literature search of MEDLINE, Embase, the Cochrane Library, ISI Web of Science and China BioMedical Disc. Primary studies, published from January 2004 to November 2014, which examined the screening accuracy of PSMSUM in pregnant Chinese women, compared with a reference standard, either chromosomal verification or inspection of the newborn. Data were extracted as screening positive/negative results for Down and non-Down syndrome pregnancies, allowing estimation of sensitivities and specificities. Risks of bias within and across studies were assessed. Screening accuracy measures were pooled using a bivariate random effects regression model. Seventy-eight studies, involving six categories of PSMSUM, were included. Second-trimester double serum [pooled sensitivity (SEN) = 0.80, pooled specificity (SPE) = 0.95] and triple-serum (pooled SEN = 0.79, pooled SPE = 0.96) screening were the predominant PSMSUM methods. The screening performances of these methods achieved the national standard but varied enormously across studies. First-trimester combined screening (pooled SEN = 0.92, pooled SPE = 0.93) and second-trimester quadruple serum screening (median SEN = 0.86, median SPE = 0.96) performed better, but were rarely used. Second-trimester maternal serum screening has the potential to achieve satisfactory screening performance in middle- and low-income countries. The reported enormous range in screening performance of second-trimester PSMSUM calls for urgent implementation of methods for performance optimization. Meta-analysis results show good accuracy of maternal serum and ultrasound screening for trisomy 21 in Chinese women. © 2016 Royal College of Obstetricians and Gynaecologists.

  5. Effect of non-surgical periodontal treatment on transferrin serum levels in patients with chronic periodontitis

    PubMed Central

    Shirmohamadi, Adileh; Chitsazi, Mohamad Taghi; Faramarzi, Masoumeh; Salari, Ashkan; Naser Alavi, Fereshteh; Pashazadeh, Nazila

    2016-01-01

    Background. Transferrin is a negative acute phase protein, which decreases during inflammation and infection. The aim of the present investigation was to evaluate changes in the transferrin serum levels subsequent to non-surgical treatment of chronic periodontal disease. Methods. Twenty patients with chronic periodontitis and 20 systemically healthy subjects without periodontal disease, who had referred to Tabriz Faculty of Dentistry, were selected. Transferrin serum levels and clinical periodontal parameters (pocket depth, clinical attachment level, gingival index, bleeding index and plaque index) were measured at baseline and 3 months after non-surgical periodontal treatment. Data were analyzed with descriptive statistical methods (means ± standard deviations). Independent samples t-test was used to compare transferrin serum levels and clinical variables between the test and control groups. Paired samples t-test was used in the test group for comparisons before and after treatment. Statistical significance was set at P < 0.05. Results. The mean transferrin serum level in patients with chronic periodontitis (213.1 ± 9.2 mg/dL) was significantly less than that in periodontally healthy subjects (307.8 ± 11.7 mg/dL). Three months after periodontal treatment, the transferrin serum level increased significantly (298.3 ± 7.6 mg/dL) and approached the levels in periodontally healthy subjects (P < 0.05). Conclusion. The decrease and increase in transferrin serum levels with periodontal disease and periodontal treatment, respectively, indicated an inverse relationship between transferrin serum levels and chronic periodontitis. PMID:27651883

  6. Systematic review of serum steroid reference intervals developed using mass spectrometry.

    PubMed

    Tavita, Nevada; Greaves, Ronda F

    2017-12-01

    The aim of this study was to perform a systematic review of the published literature to determine the available serum/plasma steroid reference intervals generated by mass spectrometry (MS) methods across all age groups in healthy subjects and to suggest recommendations to achieve common MS based reference intervals for serum steroids. MEDLINE, EMBASE and PubMed databases were used to conduct a comprehensive search for English language, MS-based reference interval studies for serum/plasma steroids. Selection of steroids to include was based on those listed in the Royal College of Pathologists of Australasia Quality Assurance Programs, Chemical Pathology, Endocrine Program. This methodology has been registered onto the PROSPERO International prospective register of systematic reviews (ID number: CRD42015029637). After accounting for duplicates, a total of 60 manuscripts were identified through the search strategy. Following critical evaluation, a total of 16 studies were selected. Of the 16 studies, 12 reported reference intervals for testosterone, 11 for 17 hydroxy-progesterone, nine for androstenedione, six for cortisol, three for progesterone, two for dihydrotestosterone and only one for aldosterone and dehydroepiandrosterone sulphate. No studies established MS-based reference intervals for oestradiol. As far as we are aware, this report provides the first comparison of the peer reviewed literature for serum/plasma steroid reference intervals generated by MS-based methods. The reference intervals based on these published studies can be used to inform the process to develop common reference intervals, and agreed reporting units for mass spectrometry based steroid methods. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  7. Category 1 external quality assessment program for serum creatinine.

    PubMed

    González-Lao, Elisabet; Díaz-Garzón, Jorge; Corte, Zoraida; Ricós, Carmen; Perich, Carmen; Álvarez, Virtudes; Simón, Margarita; Minchinela, Joana; García-Lario, José Vicente; Boned, Beatriz; Biosca, Carmen; Cava, Fernando; Fernández-Fernández, Pilar; Fernández-Calle, Pilar

    2017-03-01

    The Commission of Analytical Quality and the Committee of External Quality Programs of Spanish Society of Laboratory Medicine (SEQC) in collaboration with the Dutch Foundation for the Quality organized the first national category 1 External Quality Assessment Programs (EQAP) pilot study. The aim is to evaluate the standardization of serum creatinine measurements in the Spanish laboratories through a category 1 external quality assurance program with commutable material and reference method assigned values. A total of 87 Spanish laboratories were involved in this program in 2015. Each day a sample control was measured by duplicate during 6 consecutive days. Percentage deviations and coefficients of variation obtained were compared with quality specifications derived from biological variation. A total of 1044 creatinine results were obtained. Laboratories were coded in 11 different method-traceability combinations. Only enzymatic methods get all results within the acceptability limits. To participate in a category 1 EQAP is a valuable tool to assess the standardization degree in our country; a big effort should be made to promote laboratories to change their procedures and to use enzymatic creatinine methods, in order to achieve a satisfactory standardization degree for this important analyte.

  8. Determination of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans, and dioxin-like polychlorinated biphenyls in human serum using programmable-temperature vaporization gas chromatography with high-resolution mass spectrometry.

    PubMed

    Zhang, Lei; Zhong, Yuxin; Liu, Xin; Bao, Yan; Zhao, Yunfeng; Wu, Yongning; Cai, Zongwei; Li, Jingguang

    2017-09-01

    The determination of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans, and dioxin-like polychlorinated biphenyls in blood from a non-occupational population is essential for the investigation of adverse health effects from these pollutants. In this study, a sensitive method based on programmable-temperature vaporization with large-volume injection coupled with gas chromatography with high-resolution mass spectrometry was developed to determine these pollutants in 1-2 mL of human serum samples. Various key parameters of programmable-temperature vaporization injector, including vent temperature, vent time, vent flow, transfer temperature and transfer time were optimized by factorial design. The accuracy and precision as well as applicability were assessed by determining polychlorinated dibenzo-p-dioxins, polychlorinated dibenzofurans, and dioxin-like polychlorinated biphenyls in calibration standard solutions, standard reference materials and real human serum samples from non-occupational population. The method detection limits of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans, and dioxin-like polychlorinated biphenyls were 1.5-9.0 and 0.005-0.02 ng/kg wet weight, respectively. By comparing with typically splitless injection, the application of programmable-temperature vaporization injector could effectively lead to higher detectable rate of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans, and dioxin-like polychlorinated biphenyls in 1-2 mL of human serum samples. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Vitamin D measurement standardization: The way out of the chaos.

    PubMed

    Binkley, N; Dawson-Hughes, B; Durazo-Arvizu, R; Thamm, M; Tian, L; Merkel, J M; Jones, J C; Carter, G D; Sempos, C T

    2017-10-01

    Substantial variability is associated with laboratory measurement of serum total 25-hydroxyvitamin D [25(OH)D]. The resulting chaos impedes development of consensus 25(OH)D values to define stages of vitamin D status. As resolving this situation requires standardized measurement of 25(OH)D, the Vitamin D Standardization Program (VDSP) developed methodology to standardize 25(OH)D measurement to the gold standard reference measurement procedures of NIST, Ghent University and CDC. Importantly, VDSP developed protocols for standardizing 25(OH)D values from prior research based on availability of stored serum samples. The effect of such retrospective standardization on prevalence of "low" vitamin D status in national studies reported here for The Third National Health and Nutrition Examination Survey (NHANES III, 1988-1994) and the German Health Interview and Examination Survey for Children and Adolescents (KIGGS, 2003-2006) was such that in NHANES III 25(OH)D values were lower than original values while higher in KIGGS. In NHANES III the percentage with values below 30, 50 and 75 nmol/L increased from 4% to 6%, 22% to 31% and 55% to 71%, respectively. Whereas in KIGGS after standardization the percentage below 30, 50, and 70 nmol/L decreased from 28% to 13%, 64% to 47% and 87% to 85% respectively. Moreover, in a hypothetical example, depending on whether the 25(OH)D assay was positively or negatively biased by 12%, the 25(OH)D concentration which maximally suppressed PTH could vary from 20 to 35ng/mL. These examples underscore the challenges (perhaps impossibility) of developing vitamin D guidelines using unstandardized 25(OH)D data. Retrospective 25(OH)D standardization can be applied to old studies where stored serum samples exist. As a way forward, we suggest an international effort to identify key prior studies with stored samples for re-analysis and standardization initially to define the 25(OH)D level associated with vitamin D deficiency (rickets/osteomalacia). Subsequent work could focus on defining inadequacy. Finally, examples reported here highlight the importance of suspending publication of meta-analyses based on unstandardized 25(OH)D results. Published by Elsevier Ltd.

  10. Comparison of different commercial ELISAs for detection of antibodies against porcine respiratory and reproductive syndrome virus in serum.

    PubMed

    Sattler, Tatjana; Wodak, Eveline; Revilla-Fernández, Sandra; Schmoll, Friedrich

    2014-12-18

    In recent years, several new ELISAs for the detection of antibodies against the porcine reproductive and respiratory disease virus (PRRSV) in pig serum have been developed. To interpret the results, specificity and sensitivity data as well as agreement to a reference ELISA must be available. In this study, three commercial ELISAs (INgezim PRRS 2.0 - ELISA II, Priocheck® PRRSV Ab porcine - ELISA III and CIVTEST suis PRRS E/S PLUS - ELISA IV, detecting PRRSV type 1 antibodies) were compared to a standard ELISA (IDEXX PRRS X3 Ab Test - ELISA I). The serum of three pigs vaccinated with an attenuated PRRSV live vaccine (genotype 2) was tested prior to and several times after the vaccination. Furthermore, serum samples of 245 pigs of PRRSV positive herds, 309 pigs of monitored PRRSV negative herds, 256 fatteners of assumed PRRSV negative herds with unknown herd history and 92 wild boars were tested with all four ELISAs. ELISAs II and III were able to detect seroconversion of vaccinated pigs with a similar reliability. According to kappa coefficient, the results showed an almost perfect agreement between ELISA I as reference and ELISA II and III (kappa > 0.8), and substantial agreement between ELISA I and ELISA IV (kappa = 0.71). Sensitivity of ELISA II, III and IV was 96.0%, 100% and 91.5%, respectively. The specificity of the ELISAs determined in samples of monitored PRRSV negative herds was 99.0%, 95.1% and 96.4%, respectively. In assumed negative farms that were not continually monitored, more positive samples were found with ELISA II to IV. The reference ELISA I had a specificity of 100% in this study. All tested ELISAs were able to detect a PRRSV positive herd. The specificity and sensitivity of the tested commercial ELISAs, however, differed. ELISA II had the highest specificity and ELISA III had the highest sensitivity in comparison to the reference ELISA. ELISA IV had a lower sensitivity and specificity than the other ELISAs.

  11. Analytical and Clinical Performance Evaluation of the Abbott Architect PIVKA Assay.

    PubMed

    Ko, Dae-Hyun; Hyun, Jungwon; Kim, Hyun Soo; Park, Min-Jeong; Kim, Jae-Seok; Park, Ji-Young; Shin, Dong Hoon; Cho, Hyoun Chan

    2018-01-01

    Protein induced by vitamin K absence (PIVKA) is measured using various assays and is used to help diagnose hepatocellular carcinoma. The present study evaluated the analytical and clinical performances of the recently released Abbott Architect PIVKA assay. Precision, linearity, and correlation tests were performed in accordance with the Clinical Laboratory Standardization Institute guidelines. Sample type suitability was assessed using serum and plasma samples from the same patients, and the reference interval was established using sera from 204 healthy individuals. The assay had coefficients of variation of 3.2-3.5% and intra-laboratory variation of 3.6-5.5%. Linearity was confirmed across the entire measurable range. The Architect PIVKA assay was comparable to the Lumipulse PIVKA assay, and the plasma and serum samples provided similar results. The lower reference limit was 13.0 mAU/mL and the upper reference limit was 37.4 mAU/mL. The ability of the Architect PIVKA assay to detect hepatocellular carcinoma was comparable to that of the alpha-fetoprotein test and the Lumipulse PIVKA assay. The Architect PIVKA assay provides excellent analytical and clinical performance, is simple for clinical laboratories to adopt, and has improved sample type suitability that could broaden the assay's utility. © 2018 by the Association of Clinical Scientists, Inc.

  12. Quantification of Lyssavirus-Neutralizing Antibodies Using Vesicular Stomatitis Virus Pseudotype Particles.

    PubMed

    Moeschler, Sarah; Locher, Samira; Conzelmann, Karl-Klaus; Krämer, Beate; Zimmer, Gert

    2016-09-16

    Rabies is a highly fatal zoonotic disease which is primarily caused by rabies virus (RABV) although other members of the genus Lyssavirus can cause rabies as well. As yet, 14 serologically and genetically diverse lyssaviruses have been identified, mostly in bats. To assess the quality of rabies vaccines and immunoglobulin preparations, virus neutralization tests with live RABV are performed in accordance with enhanced biosafety standards. In the present work, a novel neutralization test is presented which takes advantage of a modified vesicular stomatitis virus (VSV) from which the glycoprotein G gene has been deleted and replaced by reporter genes. This single-cycle virus was trans-complemented with RABV envelope glycoprotein. Neutralization of this pseudotype virus with RABV reference serum or immune sera from vaccinated mice showed a strong correlation with the rapid fluorescent focus inhibition test (RFFIT). Importantly, pseudotype viruses containing the envelope glycoproteins of other lyssaviruses were neutralized by reference serum to a significantly lesser extent or were not neutralized at all. Taken together, a pseudotype virus system has been successfully developed which allows the safe, fast, and sensitive detection of neutralizing antibodies directed against different lyssaviruses.

  13. Body mass index in relation to serum prostate-specific antigen levels and prostate cancer risk.

    PubMed

    Bonn, Stephanie E; Sjölander, Arvid; Tillander, Annika; Wiklund, Fredrik; Grönberg, Henrik; Bälter, Katarina

    2016-07-01

    High Body mass index (BMI) has been directly associated with risk of aggressive or fatal prostate cancer. One possible explanation may be an effect of BMI on serum levels of prostate-specific antigen (PSA). To study the association between BMI and serum PSA as well as prostate cancer risk, a large cohort of men without prostate cancer at baseline was followed prospectively for prostate cancer diagnoses until 2015. Serum PSA and BMI were assessed among 15,827 men at baseline in 2010-2012. During follow-up, 735 men were diagnosed with prostate cancer with 282 (38.4%) classified as high-grade cancers. Multivariable linear regression models and natural cubic linear regression splines were fitted for analyses of BMI and log-PSA. For risk analysis, Cox proportional hazards regression models were used to estimate hazard ratios (HR) and 95% confidence intervals (CI) and natural cubic Cox regression splines producing standardized cancer-free probabilities were fitted. Results showed that baseline Serum PSA decreased by 1.6% (95% CI: -2.1 to -1.1) with every one unit increase in BMI. Statistically significant decreases of 3.7, 11.7 and 32.3% were seen for increasing BMI-categories of 25 < 30, 30 < 35 and ≥35 kg/m(2), respectively, compared to the reference (18.5 < 25 kg/m(2)). No statistically significant associations were seen between BMI and prostate cancer risk although results were indicative of a positive association to incidence rates of high-grade disease and an inverse association to incidence of low-grade disease. However, findings regarding risk are limited by the short follow-up time. In conclusion, BMI was inversely associated to PSA-levels. BMI should be taken into consideration when referring men to a prostate biopsy based on serum PSA-levels. © 2016 UICC.

  14. Reference intervals for serum osteocalcin concentrations in adult men and women from the study of health in Pomerania.

    PubMed

    Hannemann, Anke; Friedrich, Nele; Spielhagen, Christin; Rettig, Rainer; Ittermann, Till; Nauck, Matthias; Wallaschofski, Henri

    2013-03-13

    Osteocalcin (OC) is a bone-specific protein produced primarily by osteoblasts during bone formation. Besides its role in bone formation, osteocalcin may play a role in the regulation of energy metabolism and male fertility. To interpret serum OC data, reference intervals adapted to a specific laboratory method are needed. A healthy reference population was selected from the first follow-up of the Study of Health in Pomerania. Serum OC concentrations were measured with the IDS-iSYS N-Mid Osteocalcin assay on the IDS-iSYS Automated System (Immunodiagnostic Systems, Frankfurt am Main, Germany). The reference interval was defined as the central 95% range (2.5th-97.5th percentile). Age-specific reference intervals were calculated by quantile regression for 1107 men (25-79 years) and 545 premenopausal women (25-54 years). The reference interval for 498 postmenopausal women (50-79 years) was calculated irrespective of age. Median (1st-3rd quartile) serum OC concentrations were 15.4 ng/mL (12.0-19.4 ng/mL) in men, 14.4 ng/mL (11.3-18.5 ng/mL) in premenopausal women, and 18.6 ng/mL (13.6-25.6 ng/mL) in postmenopausal women. Serum OC concentrations were highest in men and premenopausal women aged 25-29 years, were stable during midlife, and rose again after 65 years of age in men and at transition to menopause in women. Serum OC concentrations were lower in women taking oral contraceptives or who were under hormone replacement therapy after menopause and in subjects with diabetes mellitus or with body mass index < 18 or > 30 kg/m2 than in subjects without these conditions. We established sex-specific adult reference intervals for the serum OC concentration measured by the IDS-iSYS N-Mid Osteocalcin assay.

  15. Clinical and preclinical validation of the serum free light chain assay: identification of the critical difference for optimized clinical use.

    PubMed

    Hansen, Charlotte T; Münster, Anna-Marie; Nielsen, Lars; Pedersen, Per; Abildgaard, Niels

    2012-12-01

    The use of the assay for the measurements of free light chains in serum (sFLCs) is increasing. However, there are technical limitations that potentially affect the use in serial measurements. We need further knowledge on the standards of analytical precision, the utility of conventional population-based reference values and the critical difference (CD) between serial results required for significance. To answer these questions, the biological variation must be known. We determined the biological variation in healthy individuals and patients with plasma cell dyscrasia (PCD). We assessed the imprecision of the analysis in use from FreeLite™. We determined the reference interval (RI) in 170 healthy individuals. The biological variation is identical for healthy individuals and patients with PCD. The imprecision of the sFLC analysis cannot fulfil the desirable performance standards for a laboratory test, but are within the manufacturer's ±20% variation for quality control samples. RI showed a significant increase for κ FLC and κ/λ ratio with age, but not for λ. Critical difference was calculated to be 24% and 23% for κ and λ, respectively. We suggest the use of an age-dependent RI. When monitoring patients with PCD, their own former results are the best reference, and knowledge on CD is a valuable tool, which we describe for the first time. Also, it challenges the recently proposed International Myeloma Working Group 'paraprotein relapse criteria', recommending an increase of more than 25% in the involved FLC to indicate the need for initiation of retreatment. We recommend revision of this criterion. © 2012 John Wiley & Sons A/S.

  16. Reference intervals for acute phase protein and serum protein electrophoresis values in captive Asian elephants (Elephas maximus).

    PubMed

    Isaza, Ramiro; Wiedner, Ellen; Hiser, Sarah; Cray, Carolyn

    2014-09-01

    Acute phase protein (APP) immunoassays and serum protein electrophoresis (SPEP) are assays for evaluating the inflammatory response and have use as diagnostic tools in a variety of species. Acute phase proteins are markers of inflammation that are highly conserved across different species while SPEP separates and quantifies serum protein fractions based on their physical properties. In the current study, serum samples from 35 clinically healthy Asian elephants (Elephas maximus) were analyzed using automated assays for C-reactive protein, serum amyloid A, and haptoglobin and SPEP. Robust methods were used to generate reference intervals for the APPs: C-reactive protein (1.3-12.8 mg/l), serum amyloid A (0-47.5 mg/l), and haptoglobin (0-1.10 mg/ml). In addition, SPEP was performed on these samples to establish reference intervals for each protein fraction. A combination of APPs and SPEP measurements are valuable adjunctive diagnostic tools in elephant health care. © 2014 The Author(s).

  17. Standard Specimen Reference Set: Lung — EDRN Public Portal

    Cancer.gov

    The NCI/EDRN/SPORE Lung Cancer Biomarkers Group (LCBG) began its activities back in November 2004 and developed clear objectives and strategies on how to begin validating a series of candidate biomarkers for the early detection of lung cancer. The initial goal of the LCBG is to develop the requisite sample resources to validate serum/plasma biomarkers for the early diagnosis of lung cancer. Researchers may use these resources and process for continued biomarker refinement but this is not the primary activity of the LCBG.

  18. [Comparison of the effect of different diagnostic criteria of subclinical hypothyroidism and positive TPO-Ab on pregnancy outcomes].

    PubMed

    He, Yiping; He, Tongqiang; Wang, Yanxia; Xu, Zhao; Xu, Yehong; Wu, Yiqing; Ji, Jing; Mi, Yang

    2014-11-01

    To explore the effect of different diagnositic criteria of subclinical hypothyroidism using thyroid stimulating hormone (TSH) and positive thyroid peroxidase antibodies (TPO-Ab) on the pregnancy outcomes. 3 244 pregnant women who had their antenatal care and delivered in Child and Maternity Health Hospital of Shannxi Province August from 2011 to February 2013 were recruited prospectively. According to the standard of American Thyroid Association (ATA), pregnant women with normal serum free thyroxine (FT4) whose serum TSH level> 2.50 mU/L were diagnosed as subclinical hypothyroidism in pregnancy (foreign standard group). According to the Guideline of Diagnosis and Therapy of Prenatal and Postpartum Thyroid Disease made by Chinese Society of Endocrinology and Chinese Society of Perinatal Medicine in 2012, pregnant women with serum TSH level> 5.76 mU/L, and normal FT4 were diagnosed as subclinical hypothyroidism in pregnancy(national standard group). Pregnant women with subclinical hypothyroidism whose serum TSH levels were between 2.50-5.76 mU/L were referred as the study observed group; and pregnant women with serum TSH level< 2.50 mU/L and negative TPO- Ab were referred as the control group. Positive TPO-Ab results and the pregnancy outcomes were analyzed. (1) There were 635 cases in the foreign standard group, with the incidence of 19.57% (635/3 244). And there were 70 cases in the national standard group, with the incidence of 2.16% (70/3 244). There were statistically significant difference between the two groups (P < 0.01). There were 565 cases in the study observed group, with the incidence of 17.42% (565/3 244). There was statistically significant difference (P < 0.01) when compared with the national standard group; while there was no statistically significant difference (P > 0.05) when compared with the foreign standard group. (2) Among the 3 244 cases, 402 cases had positive TPO-Ab. 318 positive cases were in the foreign standard group, and the incidence of subclinical hypothyroidism was 79.10% (318/402). There were 317 negative cases in the foreign standard group, with the incidence of 11.15% (317/2 842). The difference was statistically significant (P < 0.01) between them. In the national standard group, 46 cases had positive TPO-Ab, with the incidence of 11.44% (46/402), and 24 cases had negative result, with the incidence of 0.84% (24/2 842). There were statistically significant difference (P < 0.01) between them. In the study observed group, 272 cases were TPO-Ab positive, with the incidence of 67.66% (272/402), and 293 cases were negative, with the incidence of 10.31% (293/2 842), the difference was statistically significant (P < 0.01). (3) The incidence of miscarriage, premature delivery, gestational hypertension disease, gestational diabetes mellitus(GDM)in the foreign standard group had statistically significant differences (P < 0.05) when compared with the control group, respectively. While there was no statistically significant difference (P > 0.05) in the incidence of placental abruption or fetal distress. And the incidence of miscarriage, premature delivery, gestational hypertension disease, GDM in the national standard group had statistical significant difference (P < 0.05) compared with the control group, respectively. While there was no statistically significant difference (P > 0.05) in the incidence of placental abruption or fetal distress. This study observed group of pregnant women's abortion, gestational hypertension disease, GDM incidence respectively compared with control group, the difference had statistical significance (P < 0.05); but in preterm labor, placental abruption, and fetal distress incidence, there were no statistically significant difference (P > 0.05). (4) The incidence of miscarriage, premature delivery, gestational hypertension disease, GDM, placental abruption, fetal distress in the TPO-Ab positive cases of the national standard group showed an increase trend when compared with TPO-Ab negative cases, with no statistically significant difference (P > 0.05). The incidence of gestational hypertension disease and GDM in the TPO-Ab positive cases of the study observed group had statistical significance difference (P < 0.05) when compared with TPO-Ab negative cases; while the incidence of miscarriage, premature birth, placental abruption, fetal distress had no statistically significant difference (P > 0.05). The incidence of gestational hypertension disease and GDM in the TPO-Ab positive cases had statistically significance difference when compared with TPO-Ab negtive cases of foreign standard group (P < 0.05). (1) The incidence of subclinical hypothyroidism is rather high during early pregnancy and can lead to adverse pregnancy outcome. (2) Positive TPO-Ab result has important predictive value of the thyroid dysfunction and GDM. (3) Relatively, the ATA standard of diagnosis (serum TSH level> 2.50 mU/L) is safer for the antenatal care; the national standard (serum TSH level> 5.76 mU/L) is not conducive to pregnancy management.

  19. Serum levels of lipoprotein(a) and homocysteine in patients on hemodialysis who take hydroxymethylglutaryl-CoA reductase inhibitors, vitamin B6, and folic acid.

    PubMed

    Shojaei, Mir Hatef; Djalali, Mamhmoud; Siassi, Fereydoun; Khatami, Mohammad Reza; Boroumand, Mohammad Ali; Eshragian, Mohammad Reza

    2009-07-01

    High serum levels of lipoprotein(a) and homocysteine are risk factors of cardiovascular disease which are prevalent in patients on hemodialysis. Controversy exists about the effects of hydroxymethylglutaryl-CoA reductase inhibitors on serum lipoprotein(a) levels in patients on hemodialysis. Also, deficiency of some water soluble vitamins and administration of statins may raise serum levels of homocysteine in these patients. This study was designed to investigate serum levels of lipoprotein(a) and homocysteine in patients on hemodialysis who were taking a statin, vitamin B6, and folic acid. We investigated on 152 patients with maintenance hemodialysis who were taking atorvastatin or lovastatin, vitamin B6, and folic acid for at least 6 months. Their serum levels were obtained to measure lipoprotein(a) and homocysteine levels, as well as triglyceride, total cholesterol, high-density lipoprotein cholesterol, and low-density lipoprotein cholesterol. The mean serum values of total cholesterol, high-density lipoprotein cholesterol, and low-density lipoprotein cholesterol and triglyceride were significantly less than the maximum reference values (P < .001). The mean serum level of lipoprotein(a) was also less than the reference value (P = .009), but homocysteine level was 33% higher on average than the reference value (P < .001). Our study demonstrated that in our patients on hemodialysis, the mean serum level of homocysteine was about 30% higher than the reference value although they were receiving vitamin B6 and folic acid. Hence, they were still exposed to the risk of cardiovascular disease.

  20. The elevated serum urea:creatinine ratio in canine babesiosis in South Africa is not of renal origin.

    PubMed

    de Scally, M P; Leisewitz, A L; Lobetti, R G; Thompson, P N

    2006-12-01

    Pigmented serum, usually due to free haemoglobin and/or bilirubin, is a common finding in dogs with babesiosis, resulting in interference with all biochemical tests that rely on photochemistry. This is particularly true of urea and creatinine determinations, complicating the diagnosis of acute renal failure, which is a serious complication of babesiosis. A disproportionately raised serum urea concentration of unknown origin occurs in severely anaemic canine babesiosis patients and gives rise to an increased serum urea:creatinine ratio. The assay for cystatin-C, an excellent measure of glomerular filtration rate, is unaffected by free serum haemoglobin, and due to its different intrinsic origins, is free of influence by the metabolic derangements and organ pathology, other than renal disease, encountered in canine babesiosis. Serum cystatin-C was used to compare the concentrations of serum urea and serum creatinine in dogs with the severely anaemic form of canine babesiosis as well as a canine babesiosis-free reference group. Mean serum urea and mean serum urea:creatinine ratio were significantly elevated in the babesia-infected group relative to the reference population in this study. Mean serum creatinine and mean serum cystatin-C were within the reference ranges. Therefore an elevated urea:creatinine ratio in canine babesiosis in the presence of a normal serum creatinine concentration is considered to be caused by an elevated serum urea concentration and is most likely of non-renal origin. Serum creatinine was therefore as specific a measure of renal function as serum cystatin-C in canine babesiosis in this study. The sensitivity of serum creatinine as a measure of renal function was not established by this study. Serum urea, however, proved to be of little use compared to serum cystatin-C and serum creatinine. Serum urea should therefore not be used to diagnose renal failure in canine babesiosis.

  1. Comparison of FTIR-ATR and Raman spectroscopy in determination of VLDL triglycerides in blood serum with PLS regression

    NASA Astrophysics Data System (ADS)

    Oleszko, Adam; Hartwich, Jadwiga; Wójtowicz, Anna; Gąsior-Głogowska, Marlena; Huras, Hubert; Komorowska, Małgorzata

    2017-08-01

    Hypertriglyceridemia, related with triglyceride (TG) in plasma above 1.7 mmol/L is one of the cardiovascular risk factors. Very low density lipoproteins (VLDL) are the main TG carriers. Despite being time consuming, demanding well-qualified staff and expensive instrumentation, ultracentrifugation technique still remains the gold standard for the VLDL isolation. Therefore faster and simpler method of VLDL-TG determination is needed. Vibrational spectroscopy, including FT-IR and Raman, is widely used technique in lipid and protein research. The aim of this study was assessment of Raman and FT-IR spectroscopy in determination of VLDL-TG directly in serum with the isolation step omitted. TG concentration in serum and in ultracentrifugated VLDL fractions from 32 patients were measured with reference colorimetric method. FT-IR and Raman spectra of VLDL and serum samples were acquired. Partial least square (PLS) regression was used for calibration and leave-one-out cross validation. Our results confirmed possibility of reagent-free determination of VLDL-TG directly in serum with both Raman and FT-IR spectroscopy. Quantitative VLDL testing by FT-IR and/or Raman spectroscopy applied directly to maternal serum seems to be promising screening test to identify women with increased risk of adverse pregnancy outcomes and patient friendly method of choice based on ease of performance, accuracy and efficiency.

  2. Identification of Mouse Serum miRNA Endogenous References by Global Gene Expression Profiles

    PubMed Central

    Mi, Qing-Sheng; Weiland, Matthew; Qi, Rui-Qun; Gao, Xing-Hua; Poisson, Laila M.; Zhou, Li

    2012-01-01

    MicroRNAs (miRNAs) are recently discovered small non-coding RNAs and can serve as serum biomarkers for disease diagnosis and prognoses. Lack of reliable serum miRNA endogenous references for normalization in miRNA gene expression makes single miRNA assays inaccurate. Using TaqMan® real-time PCR miRNA arrays with a global gene expression normalization strategy, we have analyzed serum miRNA expression profiles of 20 female mice of NOD/ShiLtJ (n = 8), NOR/LtJ (n = 6), and C57BL/6J (n = 6) at different ages and disease conditions. We identified five miRNAs, miR-146a, miR-16, miR-195, miR-30e and miR-744, to be stably expressed in all strains, which could serve as mouse serum miRNA endogenous references for single assay experiments. PMID:22348064

  3. Glycerophosphate does not interact with components of parenteral nutrition.

    PubMed

    Topp, Heinrich; Hochfeld, Olena; Bark, Staffan; Grossmann, Matthias; Joukhadar, Christian; Westphal, Martin; Straatsma, Harald; Rothenburger, Markus

    2011-01-01

    The primary objective of this study was to determine and compare the pharmacokinetic (PK) profiles of inorganic phosphate in the serum after continuous administration of pure glycerophosphate and glycerophosphate contained in total parenteral nutrition (TPN) emulsions. This approach was selected to identify potential PK interactions between TPN components and glycerophosphate. The serum PK profile of inorganic phosphate after continuous intravenous administration of a sodium glycerophosphate containing TPN emulsion was determined in 10 healthy, white (5 male/5 female) volunteers. A pure sodium glycerophosphate formulation served as reference. Standard criteria of bioequivalence were applied. Subjects were enrolled in the double-blinded study and were randomly allocated to receive the test and reference preparations on two occasions in a 2-sequence crossover study design. The volunteers received 1/3 of the maximum recommended body weight- (BW) adjusted intravenous daily dosage (13.3 ml/kg BW) of the test drug over a period of 8 h. The amount of total phosphate (0.101 mmol/kg) and duration of administration were identical for the test and reference drugs. Study days were separated by washout periods of at least 88 h. Serum concentrations of total inorganic phosphate were measured serially over a 36-hour period using a validated method. A statistical mixed ANOVA, based on population averages, was used for testing bioequivalence between these study preparations. The 90% confidence intervals (90% CIs) of inorganic phosphate in serum were calculated for the test/reference ratios of the area under the time-concentration curve from time 0 to 36 h (AUC₀₋₃₆), the maximum concentration (C(max)) and the concentration 5 min before the end of infusion (C(ss)) for a bioequivalence range from 0.80 to 1.25. The mean test/reference ratios fell completely within the 90% CIs with values of 1.016 (90% CI 1.005-1.028), 1.013 (90% CI 0.981-1.047) and 0.932 (90% CI 0.886-0.980) for AUC(0-36), C(max) and C(ss), respectively. In total, 3 mild adverse events in the reference group were detected after starting intravenous infusion, while no adverse events were observed in the test group after treatment. Primary PK parameters were within the defined bioequivalence range of 0.8-1.25. Thus, inorganic phosphate levels were essentially similar between the two investigational medicinal products tested in the present study. These findings confirm the concept that nutritional components of the test drug do not significantly interact with glycerophosphate. The two study preparations proved to be safe during the investigation. Copyright © 2011 S. Karger AG, Basel.

  4. Reference Values of 14 Serum Trace Elements for Pregnant Chinese Women: A Cross-Sectional Study in the China Nutrition and Health Survey 2010–2012

    PubMed Central

    Liu, Xiaobing; Zhang, Yu; Piao, Jianhua; Mao, Deqian; Li, Yajie; Li, Weidong; Yang, Lichen; Yang, Xiaoguang

    2017-01-01

    The development of reference values of trace elements is recognized as a fundamental prerequisite for the assessment of trace element nutritional status and health risks. In this study, a total of 1400 pregnant women aged 27.0 ± 4.5 years were randomly selected from the China Nutrition and Health Survey 2010–2012 (CNHS 2010–2012). The concentrations of 14 serum trace elements were determined by high-resolution inductively coupled plasma mass spectrometry. Reference values were calculated covering the central 95% reference intervals (P2.5–P97.5) after excluding outliers by Dixon’s test. The overall reference values of serum trace elements were 131.5 (55.8-265.0 μg/dL for iron (Fe), 195.5 (107.0–362.4) μg/dL for copper (Cu), 74.0 (51.8–111.3) μg/dL for zinc (Zn), 22.3 (14.0–62.0) μg/dL for rubidium (Rb), 72.2 (39.9–111.6) μg/L for selenium (Se), 45.9 (23.8-104.3) μg/L for strontium (Sr), 1.8 (1.2–3.6) μg/L for molybdenum (Mo), 2.4 (1.2–8.4) μg/L for manganese (Mn), 1.9 (0.6–9.0) ng/L for lead (Pb), 1.1 (0.3-5.6) ng/L for arsenic (As), 835.6 (219.8–4287.7) ng/L for chromium (Cr), 337.9 (57.0–1130.0) ng/L for cobalt (Co), 193.2 (23.6–2323.1) ng/L for vanadium (V), and 133.7 (72.1–595.1) ng/L for cadmium (Cd). Furthermore, some significant differences in serum trace element reference values were observed between different groupings of age intervals, residences, anthropometric status, and duration of pregnancy. We found that serum Fe, Zn, and Se concentrations significantly decreased, whereas serum Cu, Sr, and Co concentrations elevated progressively compared with reference values of 14 serum trace elements in pregnant Chinese women. The reference values of serum trace elements established could play a key role in the following nutritional status and health risk assessment. PMID:28335545

  5. Hematology and serum chemistry reference ranges of free-ranging moose (Alces alces) in Norway.

    PubMed

    Rostal, Melinda K; Evans, Alina L; Solberg, Erling J; Arnemo, Jon M

    2012-07-01

    Baseline reference ranges of serum chemistry and hematology data can be important indicators for the status of both individuals or populations of wild animals that are affected by emerging pathogens, toxicants, or other causes of disease. Frequently, reference ranges for these values are not available for wildlife species or subspecies. We present hematologic and serum chemistry reference ranges for moose (Alces alces) adults, yearlings, and calves in Norway sampled from 1992-2000. Additionally, we demonstrated that both induction time and chase time were correlated with initial rectal temperature, although they were not significantly correlated with cortisol, aspartate aminotransferase, glucose, or creatine kinase. Overall, the reference ranges given here are similar to those given for American moose, with a few differences that can be attributed to environment, testing methodology, or subspecies or species status. This is the first report, to our knowledge, of reference ranges for moose in Norway.

  6. Calcium and Bone Metabolism Indices.

    PubMed

    Song, Lu

    2017-01-01

    Calcium and inorganic phosphate are of critical importance for many body functions, thus the regulations of their plasma concentrations are tightly controlled by the concerted actions of reabsorption/excretion in the kidney, absorption in the intestines, and exchange from bone, the major reservoir for calcium and phosphate in the body. Parathyroid hormone (PTH) and 1,25-dihydroxyvitamin D (1,25(OH) 2 D) control calcium homeostasis, whereas PTH, 1,25(OH) 2 D, and bone-derived fibroblast growth factor 23 (FGF 23) control phosphate homeostasis. Hypoparathyroidism can cause hypocalcemia and hyperphosphatemia, whereas deficient vitamin D actions can cause osteomalacia in adults and rickets in children. Hyperparathyroidism, alternatively, can cause hypercalcemia and hypophosphatemia. Laboratory tests of calcium, phosphate, PTH, and 25-hydroxyvitamin D are very useful in the diagnosis of abnormalities associated with calcium and/or phosphate metabolisms. Bone is constantly remodeled throughout life in response to mechanical stress and a need for calcium in extracellular fluids. Metabolic bone diseases such as osteoporosis, osteomalacia in adults or rickets in children, and renal osteodystrophy develop when bone resorption exceeds bone formation. Bone turnover markers (BTM) such as serum N-terminal propeptide of type I procollagen (P1NP) and C-terminal collagen cross-link (CTX) may be useful in predicting future fracture risk or monitoring the response to anti-resorptive therapy. There is a need to standardize sample collection protocols because certain BTMs exhibit large circadian variations and tend to be influenced by food intakes. In the United States, a project to standardize BTM sample collection protocols and to establish the reference intervals for serum P1NP and serum CTX is ongoing. We anticipate the outcome of this project to shine lights on the standardization of BTM assays, sample collection protocols, reference intervals in relation to age, sex, and ethnic origins, and clinical utilities of BTMs. This review will briefly discuss the regulations of calcium and phosphate homeostasis, laboratory's role in the diagnosis, and monitoring of bone and calcium metabolism, as well as the usefulness and controversies of the utilities of BTMs in the diagnosis and monitoring of metabolic bone diseases. © 2017 Elsevier Inc. All rights reserved.

  7. Remnant B-cell-stimulative and anti-oxidative effects of Persea americana fruit extract studied in rats introduced into streptozotocin - induced hyperglycaemic state.

    PubMed

    Rao, U S Mahadeva; Adinew, Bizuneh

    2011-01-01

    Insulin-stimulative and anti-oxidative effects of Persea americana fruit extract were evaluated using streptozotocin (STZ). Ethanol extract of P. americana in the concentration of 300 mg/kg body weight/rat /day was orally administered to rats introduced into STZ-induced hyperglycaemic state for a period of 30 days. After the treatment with avocado fruit extract, the elevated levels of blood glucose, glycosylated haemoglobin, blood urea and serum creatinine seen in the hyperglycaemic rats, reverted back to near normal. Similarly, significantly decreased plasma insulin and haemoglobin levels went back to near normal after the treatment, suggesting the insulin-stimulative effect of P. americana fruit. Determination of thiobarbituric acid reactive substances (TBARS), hydroperoxides and both enzymatic and non-enzymatic antioxidants, confirmed the anti-oxidative potential of avocado fruit extract which, in turn, might be responsible for its hypoglycaemic potential. Changes in activities of enzymes such as serum aspartate transaminase (AST), serum alanine transaminase (ALT), and serum alkaline phosphatase (ALP) seen in the control and experimental rats, revealed the tissue-protective nature of Persea americana fruits, while all of the analysed biochemical parameters were comparable to those obtained with gliclazide as a standard reference drug.

  8. Serum biochemical reference intervals for free-living Sand Tiger sharks (Carcharias taurus) from east Australian waters.

    PubMed

    Otway, Nicholas M

    2015-06-01

    Sharks are top-order predators in ocean food chains and the star attractions in aquaria worldwide. Unfortunately, blood biochemistry reference intervals (RI) have been determined for few species. The study aims to establish serum biochemical RI for free-living Sand Tiger sharks (Carcharias taurus) off eastern Australia. Thirty-seven sharks were captured and their sex, length, weight, reproductive maturity, and health status were recorded. After blood collection, serum analytes were quantified using standard analytical and statistical methods. Reference intervals, means, medians, and 90% confidence intervals were generated. Physiologic data from live and necropsied sharks were used to enhance the study results. Thirty healthy sharks were included in the study. Albumin could not be detected. With the exception of ALP activity, values were unaffected by sex, length, weight, age, and life-history stage. The means (RI) were: sodium 258 (249-267) mmol/L, potassium 5.0 (4.3-5.7) mmol/L, chloride 242 (227-257) mmol/L, inorganic phosphate 1.8 (1.7-2.0) mmol/L, total calcium 3.9 (3.3-4.4) mmol/L, magnesium 1.9 (1.6-2.2) mmol/L, glucose 2.7 (2.2-3.2) mmol/L, urea 377 (360-394) mmol/L, ALP 20 (8-31) U/L, ALT 3 U/L (no RI), AST 29 (13-45) U/L, CK 42 (5-79) U/L, total protein 30 (24-36) g/L, triglyceride 0.3 (0.1-0.6) mmol/L, cholesterol 1.4 (0.9-2.1) mmol/L, creatinine 32 μmol/L (no RI), total bilirubin 1.5 μmol/L (no RI), and osmolarity 1082 (1027-1136) mmol/L. These preliminary RI will assist with the clinical evaluation and treatment of captive and free-living Sand Tiger sharks worldwide. Studies with more animals will increase the precision of upper and lower reference limits. © 2015 American Society for Veterinary Clinical Pathology.

  9. 2013 ETA Guideline: Management of Subclinical Hypothyroidism

    PubMed Central

    Pearce, Simon H.S.; Brabant, Georg; Duntas, Leonidas H.; Monzani, Fabio; Peeters, Robin P.; Razvi, Salman; Wemeau, Jean-Louis

    2013-01-01

    Subclinical hypothyroidism (SCH) should be considered in two categories according to the elevation in serum thyroid-stimulating hormone (TSH) level: mildly increased TSH levels (4.0-10.0 mU/l) and more severely increased TSH value (>10 mU/l). An initially raised serum TSH, with FT4 within reference range, should be investigated with a repeat measurement of both serum TSH and FT4, along with thyroid peroxidase antibodies, preferably after a 2- to 3-month interval. Even in the absence of symptoms, replacement therapy with L-thyroxine is recommended for younger patients (<65-70 years) with serum TSH >10 mU/l. In younger SCH patients (serum TSH <10 mU/l) with symptoms suggestive of hypothyroidism, a trial of L-thyroxine replacement therapy should be considered. For such patients who have been started on L-thyroxine for symptoms attributed to SCH, response to treatment should be reviewed 3 or 4 months after a serum TSH within reference range is reached. If there is no improvement in symptoms, L-thyroxine therapy should generally be stopped. Age-specific local reference ranges for serum TSH should be considered in order to establish a diagnosis of SCH in older people. The oldest old subjects (>80-85 years) with elevated serum TSH ≤10 mU/l should be carefully followed with a wait-and-see strategy, generally avoiding hormonal treatment. If the decision is to treat SCH, then oral L-thyroxine, administered daily, is the treatment of choice. The serum TSH should be re-checked 2 months after starting L-thyroxine therapy, and dosage adjustments made accordingly. The aim for most adults should be to reach a stable serum TSH in the lower half of the reference range (0.4-2.5 mU/l). Once patients with SCH are commenced on L-thyroxine treatment, then serum TSH should be monitored at least annually thereafter. PMID:24783053

  10. Pediatric Reference Intervals for Free Thyroxine and Free Triiodothyronine

    PubMed Central

    Jang, Megan; Guo, Tiedong; Soldin, Steven J.

    2009-01-01

    Background The clinical value of free thyroxine (FT4) and free triiodothyronine (FT3) analysis depends on the reference intervals with which they are compared. We determined age- and sex-specific reference intervals for neonates, infants, and children 0–18 years of age for FT4 and FT3 using tandem mass spectrometry. Methods Reference intervals were calculated for serum FT4 (n = 1426) and FT3 (n = 1107) obtained from healthy children between January 1, 2008, and June 30, 2008, from Children's National Medical Center and Georgetown University Medical Center Bioanalytical Core Laboratory, Washington, DC. Serum samples were analyzed using isotope dilution liquid chromatography tandem mass spectrometry (LC/MS/MS) with deuterium-labeled internal standards. Results FT4 reference intervals were very similar for males and females of all ages and ranged between 1.3 and 2.4 ng/dL for children 1 to 18 years old. FT4 reference intervals for 1- to 12-month-old infants were 1.3–2.8 ng/dL. These 2.5 to 97.5 percentile intervals were much tighter than reference intervals obtained using immunoassay platforms 0.48–2.78 ng/dL for males and 0.85–2.09 ng/dL for females. Similarly, FT3 intervals were consistent and similar for males and females and for all ages, ranging between 1.5 pg/mL and approximately 6.0 pg/mL for children 1 month of age to 18 years old. Conclusions This is the first study to provide pediatric reference intervals of FT4 and FT3 for children from birth to 18 years of age using LC/MS/MS. Analysis using LC/MS/MS provides more specific quantification of thyroid hormones. A comparison of the ultrafiltration tandem mass spectrometric method with equilibrium dialysis showed very good correlation. PMID:19583487

  11. Preparation of canine C-reactive protein serum reference material: A feasibility study.

    PubMed

    Canalias, Francesca; Piñeiro, Matilde; Pato, Raquel; Peña, Raquel; Bosch, Lluís; Soler, Lourdes; García, Natalia; Lampreave, Fermín; Saco, Yolanda; Bassols, Anna

    2018-03-01

    The availability of a species-specific reference material is essential for the harmonization of results obtained in different laboratories by different methods. We describe the preparation of a canine C-reactive protein (cCRP) serum reference material containing purified cCRP stabilized in a serum matrix. The material can be used by manufacturers to assign values to their calibrator and control materials. The serum matrix was obtained using blood collected from healthy dogs, stabilized and submitted for a delipidation process. The reference material was prepared by diluting purified cCRP in the serum matrix containing 1.0 mol/L HEPES buffer, 3.0 mmol/L calcium chloride, 80,000 kUI/L aprotinin, and 1.0 mmol/L benzamidine hydrochloride monohydrate at a pH of 7.2, and dispensing (0.5 mL) the matrix into vials that were then frozen. The pilot batch of 200 vials was shown to be homogeneous and stable after a stability study at various temperatures and over a total time of 110 days. The prepared material was submitted to an assignment value study. Eight laboratories from different European countries participated by using the same reagents for an immunoturbidimetric method adapted for different analyzers. The obtained cCRP concentration in the reference material was 78.5 mg/L with an expanded uncertainty (k = 2) of 4.2 mg/L. Canine C-reactive protein serum reference material has been produced that allows harmonization of results obtained by different methods and different laboratories, thus reducing the possibility of errors and misunderstandings. © 2018 American Society for Veterinary Clinical Pathology.

  12. Analyses of laboratory data and establishment of reference values and intervals for healthy elderly people.

    PubMed

    Kubota, K; Kadomura, T; Ohta, K; Koyama, K; Okuda, H; Kobayashi, M; Ishii, C; Fujiwara, Y; Nishiora, T; Ohmae, Y; Ohmae, T; Kitajima, M

    2012-04-01

    Protein-energy malnutrition is a common disorder in the elderly. Although serum albumin is commonly used as a nutritional marker, data is lacking on serum albumin levels in the elderly. The purpose of this study was to determine whether serum albumin levels decrease with advancing age and to establish reference value and interval of laboratory data for elderly people (75 years and over). Blood samples from 13821 healthy people, 42064 outpatients, and 15959 inpatients were collected during 2008. Blood from 127 of our nutrition support team (NST) patients was also collected during August 2006 and May 2009, and analyzed. Serum albumin, hemoglobin, total cholesterol levels and lymphocyte count were determined. We analyzed the change in each parameter in accordance with age, compared the data for elderly people with younger people, and established new reference values. Clinical outcomes were examined depending on the improved reference values. Albumin was lower in older persons than in younger persons. The estimated reference value and interval were 42 (48-36) g/l in older persons and was much lower in NST patients. Hemoglobin was decreased while cholesterol and lymphocyte count were not changed in older persons: all were markedly decreased in NST patients. Terms of hospital stay were significantly longer and mortality rates were significantly higher in older persons, comparing from above to below using a new reference value of albumin (36 g/l). The serum albumin level decreases with advancing age, but it was maintained to some extent in healthy older people. Serum albumin levels related to the clinical outcome. Hemoglobin and cholesterol levels and lymphocyte count were all lower in NST patients. These measurements may be valuable markers of nutritional status and can help in guiding the need for nutritional support.

  13. Procedures for determination of detection limits: application to high-performance liquid chromatography analysis of fat-soluble vitamins in human serum.

    PubMed

    Browne, Richard W; Whitcomb, Brian W

    2010-07-01

    Problems in the analysis of laboratory data commonly arise in epidemiologic studies in which biomarkers subject to lower detection thresholds are used. Various thresholds exist including limit of detection (LOD), limit of quantification (LOQ), and limit of blank (LOB). Choosing appropriate strategies for dealing with data affected by such limits relies on proper understanding of the nature of the detection limit and its determination. In this paper, we demonstrate experimental and statistical procedures generally used for estimating different detection limits according to standard procedures in the context of analysis of fat-soluble vitamins and micronutrients in human serum. Fat-soluble vitamins and micronutrients were analyzed by high-performance liquid chromatography with diode array detection. A simulated serum matrix blank was repeatedly analyzed for determination of LOB parametrically by using the observed blank distribution as well as nonparametrically by using ranks. The LOD was determined by combining information regarding the LOB with data from repeated analysis of standard reference materials (SRMs), diluted to low levels; from LOB to 2-3 times LOB. The LOQ was determined experimentally by plotting the observed relative standard deviation (RSD) of SRM replicates compared with the concentration, where the LOQ is the concentration at an RSD of 20%. Experimental approaches and example statistical procedures are given for determination of LOB, LOD, and LOQ. These quantities are reported for each measured analyte. For many analyses, there is considerable information available below the LOQ. Epidemiologic studies must understand the nature of these detection limits and how they have been estimated for appropriate treatment of affected data.

  14. A bacterial engineered glycoprotein as a novel antigen for diagnosis of bovine brucellosis.

    PubMed

    Ciocchini, Andrés E; Serantes, Diego A Rey; Melli, Luciano J; Guidolin, Leticia S; Iwashkiw, Jeremy A; Elena, Sebastián; Franco, Cristina; Nicola, Ana M; Feldman, Mario F; Comerci, Diego J; Ugalde, Juan E

    2014-08-27

    Brucellosis is a highly contagious zoonosis that affects livestock and human beings. Laboratory diagnosis of bovine brucellosis mainly relies on serological diagnosis using serum and/or milk samples. Although there are several serological tests with different diagnostic performance and capacity to differentiate vaccinated from infected animals, there is still no standardized reference antigen for the disease. Here we validate the first recombinant glycoprotein antigen, an N-formylperosamine O-polysaccharide-protein conjugate (OAg-AcrA), for diagnosis of bovine brucellosis. This antigen can be produced in homogeneous batches without the need of culturing pathogenic brucellae; all characteristics that make it appropriate for standardization. An indirect immunoassay based on the detection of anti O-polysaccharide IgG antibodies in bovine samples was developed coupling OAg-AcrA to magnetic beads or ELISA plates. As a proof of concept and to validate the antigen, we analyzed serum, whole blood and milk samples obtained from non-infected, experimentally infected and vaccinated animals included in a vaccination/infection trial performed in our laboratory as well as more than 1000 serum and milk samples obtained from naturally infected and S19-vaccinated animals from Argentina. Our results demonstrate that OAg-AcrA-based assays are highly accurate for diagnosis of bovine brucellosis, even in vaccinated herds, using different types of samples and in different platforms. We propose this novel recombinant glycoprotein as an antigen suitable for the development of new standard immunological tests for screening and confirmatory diagnosis of bovine brucellosis in regions or countries with brucellosis-control programs. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Comparison of the vanadate oxidase method with the diazo method for serum bilirubin determination in dog, monkey, and rat.

    PubMed

    Ameri, Mehrdad; Schnaars, Henry; Sibley, John; Honor, David

    2011-01-01

    The most widely used method for bilirubin concentration determination is the diazo method, which measures the color of azobilirubin. The vanadate oxidase method is based on oxidation of bilirubin to biliverdin by vanadate. The objective of this study was to compare total and direct bilirubin concentration ([Bt] and [Bd], respectively) determined by the diazo and vanadate oxidase methods in pooled serum samples from dogs, monkeys, and rats spiked with panels of different concentrations of bilirubin standards. Pooled serum samples from 40 dogs, 40 monkeys, and 60 rats were spiked with either ditaurine conjugates of bilirubin or a standard reference material. The results obtained from both assays were compared using Deming regression analysis. The intra- and interassay precision, expressed as a percentage of the coefficient of variation (%CV), was determined for [Bt] and [Bd], and the mean percentage of recovery was calculated. The vanadate oxidase method displayed an excellent correlation (r  =  0.99-1.00) with the diazo method. Using Deming regression, there were minimal negative or positive constant and proportional biases for [Bt] and [Bd]. The precision studies revealed that the vanadate oxidase method has comparable between-run and within-run CVs to those of the diazo method. The recovery study demonstrated that the diazo method more closely approximates the expected values of [Bt]. In conclusion, the vanadate oxidase method is a simple and rapid method that can be employed as an alternative to the diazo method when interfering substances are present in the serum samples of dog, monkey, and rat.

  16. Development of dried serum spot sampling techniques for the assessment of trace elements in serum samples by LA-ICP-MS.

    PubMed

    Chantada-Vázquez, María Pilar; Moreda-Piñeiro, Jorge; Cantarero-Roldán, Alicia; Bermejo-Barrera, Pilar; Moreda-Piñeiro, Antonio

    2018-08-15

    A novel approach for serum analysis by dried matrix spot (DMS) technique is proposed. The methodology consists of sampling filter paper discs (2.7 mm in diameter) containing the large amount of serum retained after a single spotting. Several oxidizers (sodium chlorate, sodium azide, acetic acid, formic acid, 1-butyl-3-methylimidazoliumm chloride/bromide) were tested (oxidizers premixed with the sample before spotting, and papers previously soaked in concentrated additive/oxidizer solutions). Direct multi-element determination (Al, Be, Ca, Cu, Fe, K, Li, Mg, Mn, Mo, Na, P, Rb, Se, V, and Zn) in dried serum spots at very low levels was therefore assessed by laser ablation (LA) coupled with inductively coupled plasma - mass spectrometry (ICP-MS). Laser ablation was performed using a focused Nd: YAG laser beam in lineal scan mode (wavelength 213 nm, laser fluency 2.2 J cm -2 , repetition rate 20 Hz, laser spot diameter 90 µm, depth 0 µm, scanning speed 12 µm s -1 ). Matrix-matched calibration mode and 13 C as internal standard (for signal intensities normalization) was used throughout the work. Limits of quantification were found to be from 21 µg L -1 to 221 mg L -1 . Repeatability (seven ablations of the same dried serum spot) and reproducibility (two ablations of seven dried serum spot from the same material) offered RSDs below 12% for all analytes, which seems satisfactory for clinical purposes. The method was validated by analyzing several certified reference materials (Seronorm™ level I and II trace elements in serum), and it was applied to several DMS from serum samples from healthy adults. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Serum bicarbonate and mortality in adults in NHANES III.

    PubMed

    Raphael, Kalani L; Zhang, Yingying; Wei, Guo; Greene, Tom; Cheung, Alfred K; Beddhu, Srinivasan

    2013-05-01

    Low serum bicarbonate concentration is a risk factor for death in people with chronic kidney disease (CKD). Whether low serum bicarbonate is a mortality risk factor for people without CKD is unknown. National Health and Nutrition Examination Survey III (NHANES III) adult participants were categorized into one of four serum bicarbonate categories: <22, 22-25, 26-30 and ≥ 31 mM. Cox models were used to determine the hazards of death in each serum bicarbonate category, using 26-30 mM as the reference group, in the (i) entire population, (ii) non-CKD subgroup and (iii) CKD subgroup. After adjusting for age, gender, race, estimated glomerular filtration rate, albuminuria, diuretic use, smoking, C-reactive protein, cardiovascular disease, protein intake, diabetes, hypertension, body mass index, lung disease and serum albumin, the hazards of death in the <22 mM serum bicarbonate category were 1.75 (95% CI: 1.12-2.74), 1.56 (95% CI: 0.78-3.09) and 2.56 (95% CI: 1.49-4.38) in the entire population, non-CKD subgroup and CKD subgroup, respectively, compared with the reference group. Hazard ratios in the other serum bicarbonate categories in the entire population and non-CKD and CKD subgroups did not differ from the reference group. Among the NHANES III participants, low serum bicarbonate was not observed to be a strong predictor of mortality in people without CKD. However, low serum bicarbonate was associated with a 2.6-fold increased hazard of death in people with CKD.

  18. Determination of Zn/Cu ratio and oligoelements in serum samples by total reflection X-ray fluorescence spectrometry for cancer diagnosis

    NASA Astrophysics Data System (ADS)

    Marcó P., L. M.; Jiménez, E.; Hernández C., E. A.; Rojas, A.; Greaves, E. D.

    2001-11-01

    The method of quantification using the Compton peak as an internal standard, developed in a previous work, was applied to the routine determination of Fe, Cu, Zn and Se in serum samples from normal individuals and cancer patients by total reflection X-ray fluorescence spectrometry. Samples were classified according to age and sex of the donor, in order to determine reference values for normal individuals. Results indicate that the Zn/Cu ratio and the Cu concentration could prove to be useful tools for cancer diagnosis. Significant differences in these parameters between the normal and cancer group were found for all age ranges. The multielemental character of the technique, coupled with the small amounts of sample required and the short analysis time make it a valuable tool in clinical analysis.

  19. Exposure of wild waterfowl to Mycoplasma anatis

    USGS Publications Warehouse

    Samuel, M.D.; Goldberg, Diana R.; Thomas, C.B.; Sharp, P.; Robb, J.R.; Krapu, G.L.; Nersessian, B.N.; Kenow, K.P.; Korschgen, C.E.; Chipley, W.H.; Conroy, M.J.

    1996-01-01

    We developed an ELISA procedure to assess the presence of M. Anatis-specific serum antibody in ducks. Sera from exposed and unexposed Pekin ducks (Anas platyrhynchos) were used to standardize tile ELISA and to establish reference ranges to classify ELISA results as exposed or not exposed. We conducted serological surveys of female waterfowl in the central and eastern United States between 1988 and 1992 to assess the frequency of exposure in wild waterfowl. Adult breeding mallards (Anas platyrhynchos), wintering mallards, and black ducks (Anas rubripes) had high prevalences of exposure to M. Anatis (25% to >80%). In comparison, none of the breeding adult canvasbacks (Aythya valisineria) had serum antibody levels indicating exposure. Approximately 50% of the juvenile mallards and black ducks were exposed to M. Anatis by 8 months of age, indicating high transmission rates among wild birds.

  20. Protein Quantification by Derivatization-Free High-Performance Liquid Chromatography of Aromatic Amino Acids

    PubMed Central

    Hesse, Almut

    2016-01-01

    Amino acid analysis is considered to be the gold standard for quantitative peptide and protein analysis. Here, we would like to propose a simple HPLC/UV method based on a reversed-phase separation of the aromatic amino acids tyrosine (Tyr), phenylalanine (Phe), and optionally tryptophan (Trp) without any derivatization. The hydrolysis of the proteins and peptides was performed by an accelerated microwave technique, which needs only 30 minutes. Two internal standard compounds, homotyrosine (HTyr) and 4-fluorophenylalanine (FPhe) were used for calibration. The limit of detection (LOD) was estimated to be 0.05 µM (~10 µg/L) for tyrosine and phenylalanine at 215 nm. The LOD for a protein determination was calculated to be below 16 mg/L (~300 ng BSA absolute). Aromatic amino acid analysis (AAAA) offers excellent accuracy and a precision of about 5% relative standard deviation, including the hydrolysis step. The method was validated with certified reference materials (CRM) of amino acids and of a pure protein (bovine serum albumin, BSA). AAAA can be used for the quantification of aromatic amino acids, isolated peptides or proteins, complex peptide or protein samples, such as serum or milk powder, and peptides or proteins immobilized on solid supports. PMID:27559481

  1. Hematologic and serum chemistry reference intervals for free-ranging lions (Panthera leo).

    PubMed

    Maas, Miriam; Keet, Dewald F; Nielen, Mirjam

    2013-08-01

    Hematologic and serum chemistry values are used by veterinarians and wildlife researchers to assess health status and to identify abnormally high or low levels of a particular blood parameter in a target species. For free-ranging lions (Panthera leo) information about these values is scarce. In this study 7 hematologic and 11 serum biochemistry values were evaluated from 485 lions from the Kruger National Park, South Africa. Significant differences between sexes and sub-adult (≤ 36 months) and adult (>36 months) lions were found for most of the blood parameters and separate reference intervals were made for those values. The obtained reference intervals include the means of the various blood parameter values measured in captive lions, except for alkaline phosphatase in the subadult group. These reference intervals can be utilized for free-ranging lions, and may likely also be used as reference intervals for captive lions. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. Serum level of vitamin D3 in cutaneous melanoma

    PubMed Central

    de Oliveira, Renato Santos; de Oliveira, Daniel Arcuschin; Martinho, Vitor Augusto Melão; Antoneli, Célia Beatriz Gianotti; Marcussi, Ludmilla Altino de Lima; Ferreira, Carlos Eduardo dos Santos

    2014-01-01

    Objective To compare the level of vitamin D3 in cutaneous melanoma patients, with or without disease activity, with reference values and with patients from a general hospital. Methods The serum levels of vitamin D3 were measured in cutaneous melanoma patients, aged 20 to 88 years, both genders, from January 2010 to December 2013. The samples from the general group were processed at Hospital Israelita Albert Einstein (control group). Data analysis was performed using the Statistics software. Results A total of 100 patients were studied, 54 of them men, with mean age of 54.67 years, and 95 Caucasian. Out of these 100 patients, 17 had active disease. The average levels of vitamin D3 in the melanoma patients were lower than the level considered sufficient, but above the average of the control group. Both groups (with or without active disease) of patients showed a similar distribution of vitamin D3 deficiency. Conclusion Vitamin D3 levels in melanoma patients were higher than those of general patients and lower than the reference level. If the reference values are appropriate, a large part of the population had insufficient levels of vitamin D, including those with melanoma, or else, this standard needs to be reevaluated. No difference in vitamin D3 levels was found among melanoma patients with or without active disease. More comprehensive research is needed to assess the relation between vitamin D and melanoma. PMID:25628199

  3. Multicenter performance evaluation of a second generation cortisol assay.

    PubMed

    Vogeser, Michael; Kratzsch, Jürgen; Ju Bae, Yoon; Bruegel, Mathias; Ceglarek, Uta; Fiers, Tom; Gaudl, Alexander; Kurka, Hedwig; Milczynski, Christoph; Prat Knoll, Cristina; Suhr, Anna C; Teupser, Daniel; Zahn, Ingrid; Ostlund, Richard E

    2017-05-01

    Untreated disorders of the adrenocortical system, such as Cushing's or Addison's disease, can be fatal, and accurate quantification of a patient's cortisol levels is vital for diagnosis. The objective of this study was to assess the analytical performance of a new fully-automated Elecsys® Cortisol II assay (second generation) to measure cortisol levels in serum and saliva. Four European investigational sites assessed the intermediate precision and reproducibility of the Cortisol II assay (Roche Diagnostics) under routine conditions. Method comparisons of the Cortisol II assay vs. liquid chromatography-tandem mass spectrometry (LC-MS/MS), the gold standard for cortisol measurement, were performed. Cortisol reference ranges from three US sites were determined using samples from self-reported healthy individuals. The coefficients of variation (CVs) for repeatability, intermediate precision, and reproducibility for serum samples were ≤2.6%, ≤5.8%, and ≤9.5%, respectively, and for saliva were ≤4.4% and ≤10.9%, and ≤11.4%, respectively. Agreement between the Cortisol II assay and LC-MS/MS in serum samples was close, with a slope of 1.02 and an intercept of 4.473 nmol/L. Reference range samples were collected from healthy individuals (n=300) and serum morning cortisol concentrations (5-95th percentile) were 166.1-507 nmol/L and afternoon concentrations were 73.8-291 nmol/L. Morning, afternoon, and midnight saliva concentrations (95th percentile) were 20.3, 6.94, and 7.56 nmol/L, respectively. The Cortisol II assay had good precision over the entire measuring range and had excellent agreement with LC-MS/MS. This test was found suitable for routine diagnostic application and will be valuable for the diagnosis of adrenocortical diseases.

  4. High frequency of discordance between antimüllerian hormone and follicle-stimulating hormone levels in serum from estradiol-confirmed days 2 to 4 of the menstrual cycle from 5,354 women in U.S. fertility centers.

    PubMed

    Leader, Benjamin; Hegde, Aparna; Baca, Quentin; Stone, Kimberly; Lannon, Benjamin; Seifer, David B; Broekmans, Frank; Baker, Valerie L

    2012-10-01

    To determine the frequency of clinical discordance between antimüllerian hormone (AMH, ng/mL) and follicle-stimulating hormone (FSH, IU/L) by use of cut points defined by response to controlled ovarian stimulation in the same serum samples drawn on estradiol-confirmed, menstrual cycle days 2 to 4. Retrospective analysis. Fertility centers in 30 U.S. states and a single reference laboratory with uniform testing protocols. 5,354 women, 20 to 45 years of age. None. Frequency of discordance between serum AMH and FSH values. Of the 5,354 women tested, 1 in 5 had discordant AMH and FSH values defined as AMH <0.8 (concerning) with FSH <10 (reassuring) or AMH ≥ 0.8 (reassuring) with FSH ≥ 10 (concerning). Of the women with reassuring FSH values (n = 4,469), the concerning AMH values were found in 1 in 5 women in a highly age-dependent fashion, ranging from 1 in 11 women under 35 years of age to 1 in 3 women above 40 years of age. On the other hand, of the women with reassuring AMH values (n = 3,742), 1 in 18 had concerning FSH values, a frequency that did not vary in a statistically significant fashion by age. Clinical discordance in serum AMH and FSH values was frequent and age dependent using common clinical cut points, a large patient population, one reference laboratory, and uniform testing methodology. This conclusion is generalizable to women undergoing fertility evaluation, although AMH testing has not been standardized among laboratories, and the cut points presented are specific to the laboratory in this study. Copyright © 2012. Published by Elsevier Inc.

  5. Community exposure to hazardous site remediation in rural New Zealand: an exposed-referent study of serum dioxins and health effects.

    PubMed

    McBride, David; Lovelock, Kirsten; Shepherd, Daniel; Dirks, Kim; Welch, David; Gray, Andrew

    2016-10-01

    The New Zealand Ministry of Health responded to community concern about dioxin exposure during on-site remediation of a pesticide-contaminated rural area by commissioning this exposed-referent study of serum dioxins and health in local residents. All 200 residents were eligible, with age and sex matching to demographically comparable referents. Face-to-face interviews included questions on health status, health-related quality of life (HRQOL) and perceptions about community consultation. Thirty serum samples were obtained, eligibility being based on likelihood of exposure and age. Both HRQOL and serum outcomes were analysed by the appropriate regression methods. Of 200 eligible residents, 139 (69.5%) participated, with 139 matched referents. Mapua residents had lower physical and psychological HRQOL scores, but no difference in health status. 2,3,7,8 TCDD was below the limit of detection in the majority of all serum samples, with some congeners being higher in referents. Perceptions of the communication process were equivocal. Both dioxin levels and measures of health did not differ significantly between the exposed community and controls. Implications for public health: The results suggest neither significant dioxin exposure nor community health effects. Oversight by expert panel with health expertise, allied to sound communication, may have helped the community understand the risks. © 2016 Public Health Association of Australia.

  6. Achievements and Future Directions of the APFCB Mass Spectrometry Harmonisation Project on Serum Testosterone.

    PubMed

    Greaves, Ronda F; Ho, Chung S; Hoad, Kirsten E; Joseph, John; McWhinney, Brett; Gill, Janice P; Koal, Therese; Fouracre, Chris; Iu, Heidi P; Cooke, Brian R; Boyder, Conchita; Pham, Hai T; Jolly, Lisa M

    2016-05-01

    As an outcome of the 2010 Asian Pacific Conference for Chromatography and Mass Spectrometry in Hong Kong, a collaborative working group was formed to promote the harmonisation of mass spectrometry methods. The Mass Spectrometry Harmonisation Working Group resides under the combined auspices of the Asia-Pacific Federation for Clinical Biochemistry and Laboratory Medicine (APFCB) and the Australasian Association of Clinical Biochemists (AACB). A decision was made to initially focus attention on serum steroids due to the common interest of members in this area; with the first steroid to assess being testosterone. In principle, full standardisation with traceability should be achievable for all steroids as they are small compounds with defined molecular weight and structure. In order to achieve this we need certified reference materials, reference methods, reference laboratories, reference intervals and external quality assurance programs; each being an important pillar in the process. When all the pillars are present, such as for serum testosterone, it is feasible to fully standardise the liquid chromatography - tandem mass spectrometry (LC-MS/MS) methods. In a collaborative process with interested stakeholders, we commenced on a pathway to provide ongoing assessment and seek opportunities for improvement in the LC-MS/MS methods for serum steroids. Here we discuss the outcomes to date and major challenges related to the accurate measurement of serum steroids with a focus on serum testosterone.

  7. Serum selenium level and gestational diabetes mellitus: a systematic review and meta-analysis.

    PubMed

    Kong, Fei-Juan; Ma, Lei-Lei; Chen, Shu-Ping; Li, Ge; Zhou, Jia-Qiang

    2016-10-28

    The association between serum selenium level and gestational diabetes mellitus (GDM) is controversial. The aim of our study was to systematically review available literature linking selenium to GDM for a comprehensive understanding of the relationship between serum selenium level and GDM in human. PubMed, The Cochrane Library and Medline were searched for studies published up to August 2016. Manual searches of references of the relevant original studies were carried out. Pooled estimates were measured using the fixed or random effect model. Overall effect was reported in a standard mean difference (SMD). All data were analyzed with Review Manager 5.3 and Stata 12.0. Of 44 references reviewed, seven studies involving 569 patients met our inclusion criteria and contributed to meta-analysis. All the studies were used to evaluate the relationship between serum selenium level and GDM. Selenium level was significantly lower in women with GDM than those without GDM (SMD = -1.17; 95 % CI: -1.98 to -0.35, P = 0.005). Subgroup analysis showed that such trend was consistent within the non-Caucasian population (Asia: SMD = -2.82; 95 % CI: -5.21 to -0.43, P = 0.02; Africa: SMD = -0.56; 95 % CI: -1.07 to -0.05, P = 0.03) and in the third trimester (SMD = -1.78; 95 % CI: -3.04 to -0.52, P = 0.006), but not within the Caucasian population (Europe: SMD = -0.6; 95 % CI: -1.98 to 0.78, P = 0.39) or in the second trimester (SMD = -0.68; 95 % CI: -1.6 to 0.25, P = 0.15). The available evidences suggested that serum selenium level was lower in women with GDM than those with normal glucose tolerance, especially within the non-Caucasian population and in the third trimester. However, well-designed prospective studies are needed to understand dynamic associations between selenium status and GDM risk.

  8. Use of Fourier-transform infrared spectroscopy to quantify immunoglobulin G concentration and an analysis of the effect of signalment on levels in canine serum.

    PubMed

    Seigneur, A; Hou, S; Shaw, R A; McClure, Jt; Gelens, H; Riley, C B

    2015-01-15

    Deficiency in immunoglobulin G (IgG) is associated with an increased susceptibility to infections in humans and animals, and changes in IgG levels occur in many disease states. In companion animals, failure of transfer of passive immunity is uncommonly diagnosed but mortality rates in puppies are high and more than 30% of these deaths are secondary to septicemia. Currently, radial immunodiffusion (RID) and enzyme-linked immunosorbent assays are the most commonly used methods for quantitative measurement of IgG in dogs. In this study, a Fourier-transform infrared spectroscopy (FTIR) assay for canine serum IgG was developed and compared to the RID assay as the reference standard. Basic signalment data and health status of the dogs were also analyzed to determine if they correlated with serum IgG concentrations based on RID results. Serum samples were collected from 207 dogs during routine hematological evaluation, and IgG concentrations determined by RID. The FTIR assay was developed using partial least squares regression analysis and its performance evaluated using RID assay as the reference test. The concordance correlation coefficient was 0.91 for the calibration model data set and 0.85 for the prediction set. A Bland-Altman plot showed a mean difference of -89 mg/dL and no systematic bias. The modified mean coefficient of variation (CV) for RID was 6.67%, and for FTIR was 18.76%. The mean serum IgG concentration using RID was 1943 ± 880 mg/dL based on the 193 dogs with complete signalment and health data. When age class, gender, breed size and disease status were analyzed by multivariable ANOVA, dogs < 2 years of age (p = 0.0004) and those classified as diseased (p = 0.03) were found to have significantly lower IgG concentrations than older and healthy dogs, respectively. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Quantification of Lyssavirus-Neutralizing Antibodies Using Vesicular Stomatitis Virus Pseudotype Particles

    PubMed Central

    Moeschler, Sarah; Locher, Samira; Conzelmann, Karl-Klaus; Krämer, Beate; Zimmer, Gert

    2016-01-01

    Rabies is a highly fatal zoonotic disease which is primarily caused by rabies virus (RABV) although other members of the genus Lyssavirus can cause rabies as well. As yet, 14 serologically and genetically diverse lyssaviruses have been identified, mostly in bats. To assess the quality of rabies vaccines and immunoglobulin preparations, virus neutralization tests with live RABV are performed in accordance with enhanced biosafety standards. In the present work, a novel neutralization test is presented which takes advantage of a modified vesicular stomatitis virus (VSV) from which the glycoprotein G gene has been deleted and replaced by reporter genes. This single-cycle virus was trans-complemented with RABV envelope glycoprotein. Neutralization of this pseudotype virus with RABV reference serum or immune sera from vaccinated mice showed a strong correlation with the rapid fluorescent focus inhibition test (RFFIT). Importantly, pseudotype viruses containing the envelope glycoproteins of other lyssaviruses were neutralized by reference serum to a significantly lesser extent or were not neutralized at all. Taken together, a pseudotype virus system has been successfully developed which allows the safe, fast, and sensitive detection of neutralizing antibodies directed against different lyssaviruses. PMID:27649230

  10. Performance of serological tests for syphilis in sexually transmitted diseases clinics in Guangxi Autonomous Region, China: implications for syphilis surveillance and control.

    PubMed

    Yin, Yue-Ping; Wei, Wan-Hui; Wang, Hong-Chun; Zhu, Bang-Yong; Yu, Yan-Hua; Chen, Xiang-Sheng; Peeling, Rosanna W; Cohen, Myron S

    2009-03-01

    China is experiencing a growing syphilis epidemic. Individuals are currently screened and cases are confirmed using traditional serological testing methods. A total of 11 558 serum specimens from patients at 14 sexually transmitted diseases (STD) clinics at provincial, prefecture and county levels in Guangxi Autonomous Region were tested at local clinics using the toluidine red unheated serum test (TRUST) and the SD Bioline Syphilis 3.0 Treponema Pallidum (SD-TP) test and then transported to the National STD Reference Laboratory for TRUST and confirmatory Treponema pallidum particle assay (TPPA) testing. In local clinics, 13.2% of specimens were TRUST positive and 12.8% were TRUST and SD-TP positive. At the Reference Laboratory, 15.4% of specimens were TRUST positive and 11.8% were TRUST and TPPA positive. Local clinics showed a significantly higher prevalence of active syphilis compared with results from the Reference Laboratory (12.8 v. 11.8%, chi(2) = 4.59, P = 0.03). The local TRUST tests had consistent results with Reference Laboratory tests qualitatively among 96.2% of the specimens and quantitatively among 95.5% of the specimens. The algorithm of TRUST screening and then SD-TP confirmation among positive TRUST specimens at local STD clinics had 96.6% sensitivity and 99.3% specificity in diagnosing active syphilis compared with the 'gold standard' based on TRUST and TPPA positivity at the Reference Laboratory (positive predictive value 95.1% and negative predictive value 99.5%). The TRUST screening and SD-TP confirmation in combination can be used at local STD clinics for the efficient diagnosis of serologically active syphilis. However, continuing capacity building and quality assurance remain critical in ensuring the quality of syphilis diagnosis at local clinics.

  11. The impact of change in albumin assay on reference intervals, prevalence of 'hypoalbuminaemia' and albumin prescriptions.

    PubMed

    Coley-Grant, Deon; Herbert, Mike; Cornes, Michael P; Barlow, Ian M; Ford, Clare; Gama, Rousseau

    2016-01-01

    We studied the impact on reference intervals, classification of patients with hypoalbuminaemia and albumin infusion prescriptions on changing from a bromocresol green (BCG) to a bromocresol purple (BCP) serum albumin assay. Passing-Bablok regression analysis and Bland-Altman plot were used to compare Abbott BCP and Roche BCG methods. Linear regression analysis was used to compare in-house and an external laboratory Abbott BCP serum albumin results. Reference intervals for Abbott BCP serum albumin were derived in two different laboratories using pathology data from adult patients in primary care. Prescriptions for 20% albumin infusions were compared one year before and one year after changing the albumin method. Abbott BCP assay had a negative bias of approximately 6 g/L compared with Roche BCG method.There was good agreement (y = 1.04 x - 1.03; R(2 )= 0.9933) between in-house and external laboratory Abbott BCP results. Reference intervals for the serum albumin Abbott BCP assay were 31-45 g/L, different to those recommended by Pathology Harmony and the manufacturers (35-50 g/L). Following the change in method there was a large increase in the number of patients classified as hypoalbuminaemic using Pathology Harmony references intervals (32%) but not when retrospectively compared to locally derived reference intervals (16%) compared with the previous year (12%). The method change was associated with a 44.6% increase in albumin prescriptions. This equated to an annual increase in expenditure of £35,234. We suggest that serum albumin reference intervals be method specific to prevent misclassification of albumin status in patients. Change in albumin methodology may have significant impact on hospital resources. © The Author(s) 2015.

  12. Serum ARCHITECT PIVKA-II reference interval in healthy Chinese adults: Sub-analysis from a prospective multicenter study.

    PubMed

    Yan, Cunling; Hu, Jian; Yang, Jia; Chen, Zhaoyun; Li, Huijun; Wei, Lianhua; Zhang, Wei; Xing, Hao; Sang, Guoyao; Wang, Xiaoqin; Han, Ruilin; Liu, Ping; Li, Zhihui; Li, Zhiyan; Huang, Ying; Jiang, Li; Li, Shunjun; Dai, Shuyang; Wang, Nianyue; Yang, Yongfeng; Ma, Li; Soh, Andrew; Beshiri, Agim; Shen, Feng; Yang, Tian; Fan, Zhuping; Zheng, Yijie; Chen, Wei

    2018-04-01

    Protein induced by vitamin K absence or antagonist-II (PIVKA-II) has been widely used as a biomarker for liver cancer diagnosis in Japan for decades. However, the reference intervals for serum ARCHITECT PIVKA-II have not been established in the Chinese population. Thus, this study aimed to measure serum PIVKA-II levels in healthy Chinese subjects. This is a sub-analysis from the prospective, cross-sectional and multicenter study (ClinicalTrials.gov Identifier: NCT03047603). A total of 892 healthy participants (777 Han and 115 Uygur) with complete health checkup results were recruited from 7 regional centers in China. Serum PIVKA-II level was measured by ARCHITECT immunoassay. All 95% reference ranges were estimated by nonparametric method. The distribution of PIVKA-II values showed significant difference with ethnicity and sex, but not age. The 95% reference range of PIVKA-II was 13.62-40.38 mAU/ml in Han Chinese subjects and 15.16-53.74 mAU/ml in Uygur subjects. PIVKA-II level was significantly higher in males than in females (P < 0.001). The 95% reference range of PIVKA-II was 15.39-42.01 mAU/ml in Han males while 11.96-39.13 mAU/ml in Han females. The reference interval of serum PIVKA-II on the Architect platform was established in healthy Chinese adults. This will be valuable for future clinical and laboratory studies performed using the Architect analyzer. Different ethnic backgrounds and analytical methods underline the need for redefining the reference interval of analytes such as PIVKA-II, in central laboratories in different countries. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  13. Reference intervals for serum biochemistries of molting Pacific Black Brant (Branta bernicla nigricans) in Northern Alaska, USA

    USGS Publications Warehouse

    Franson, J. Christian; Flint, Paul L.; Schmutz, Joel A.

    2017-01-01

    We determined reference intervals for nine serum biochemistries in samples from 329 molting, after-hatch-year, Pacific Black Brant (Branta bernicla nigricans) in Alaska, US. Cholesterol and nonesterified fatty acids differed by sex, but no other differences were noted.

  14. Hepatocyte growth factor, a biomarker of macroangiopathy in diabetes mellitus

    PubMed Central

    Konya, Hiroyuki; Miuchi, Masayuki; Satani, Kahori; Matsutani, Satoshi; Tsunoda, Taku; Yano, Yuzo; Katsuno, Tomoyuki; Hamaguchi, Tomoya; Miyagawa, Jun-Ichiro; Namba, Mitsuyoshi

    2014-01-01

    Atherosclerotic involvements are an essential causal element of prospect in diabetes mellitus (DM), with carotid atherosclerosis (CA) being a common risk-factor for prospective crisis of coronary artery diseases (CAD) and/or cerebral infarction (CI) in DM subjects. From another point of view, several reports have supplied augmenting proof that hepatocyte growth factor (HGF) has a physiopathological part in DM involvements. HGF has been a mesenchymal-derived polyphenic factor which modulates development, motion, and morphosis of diverse cells, and has been regarded as a humor intermediator of epithelial-mesenchymal interplays. The serum concentrations of HGF have been elevated in subjects with CAD and CI, especially during the acute phase of both disturbances. In our study with 89 type 2 DM patients, the association between serum concentrations of HGF and risk-factors for macrovascular complications inclusive of CA were examined. The average of serum HGF levels in the subjects was more elevated than the reference interval. The serum HGF concentrations associated positively with both intimal-media thickness (IMT) (r = 0.24, P = 0.0248) and plaque score (r = 0.27, P = 0.0126), indicating a relationship between the elevated HGF concentrations and advancement of CA involvements. Multivariate statistical analysis accentuated that serum concentrations of HGF would be associated independently with IMT (standardized = 0.28, P = 0.0499). The review indicates what is presently known regarding serum HGF might be a new and meaningful biomarker of macroangiopathy in DM subjects. PMID:25317245

  15. Clinical utility of serum HER-2/neu testing on the Bayer Immuno 1 automated system in breast cancer.

    PubMed

    Cook, G B; Neaman, I E; Goldblatt, J L; Cambetas, D R; Hussain, M; Lüftner, D; Yeung, K K; Chan, D W; Schwartz, M K; Allard, W J

    2001-01-01

    The clinical utility of automated serum HER-2/neu measurements in breast cancer run on the Bayer random analyzer Immuno 1 was analyzed in several steps: [a] The reference interval was determined for 242 normal healthy pre- and postmenopausal females. [b] The clinical specificity of serum HER-2/neu to separate healthy controls from 210 patients with non-malignant breast--and non-breast diseases was calculated. [c] The clinical sensitivity of cross-sectional serum HER-2/neu values for 204 patients (pts) with stage I-IV breast cancer was established. [d] Specimens from 103 stage IV breast cancer pts were tested for their parallel between serial serum HER-2/neu results and disease course. [a] The value of 13.03 ng/ml exceeded 95% of the results from the healthy female population. Based on the mean +2 standard deviations value of 14.7 ng/dl, the upper limit of normal was established at 15 ng/ml. [b] The specificity for benign breast diseases and other benign non-breast diseases was 98.0% and 94.6%, respectively. [c] The correlation of increased serum HER-2/neu levels and stage of breast cancer revealed the best sensitivity of 40% for stage IV disease. [4] Thirty-eight (36.9%) of 103 stage IV patients had initial HER-2/neu values > 15 ng/ml, 33 of whom showed longitudinal HER-2/neu concentrations which paralleled the clinical course of the disease giving a sensitivity of 86.8%.

  16. Increased serum level of homocysteine correlates with retinal nerve fiber layer thinning in diabetic retinopathy

    PubMed Central

    Srivastav, Khushboo; Mahdi, Abbas A.; Shukla, Rajendra K.; Meyer, Carsten H.; Akduman, Levent; Khanna, Vinay K.

    2016-01-01

    Purpose To study the correlation between serum levels of vitamin B12, folic acid, and homocysteine and the severity of diabetic retinopathy and the correlation with retinal nerve fiber layer (RNFL) thinning on spectral domain optical coherence tomography (SD-OCT). Methods In a tertiary care center–based prospective cross-sectional study, 60 consecutive cases and 20 healthy controls in the age group of 40–65 years were included. The eyes of the cases were divided into three groups according to Early Treatment Diabetic Retinopathy Study (ETDRS) classification: diabetes mellitus without retinopathy (n = 20), non-proliferative diabetic retinopathy with macular edema (n = 20), and proliferative diabetic retinopathy with macular edema (n = 20). The serum levels of vitamin B12 and folic acid were measured using a standard protocol. The serum homocysteine assay was performed using an enzyme-linked immunosorbent assay (ELISA) kit. Average RNFL thickness was measured using SD-OCT. Statistical analysis was used to assess the correlations between the study variables. Results Increased severity of diabetic retinopathy was found to correlate with an increase in the serum levels of homocysteine (F = 53.79; p<0.001). The mean serum levels of vitamin B12 and folic acid were found to be within the normal reference range. A positive correlation was found between retinal nerve fiber layer thinning and serum levels of homocysteine (p<0.001). Conclusions This study, for the first time, demonstrated a correlation between increased homocysteine with a decrease in RNFL thickness and increased severity of diabetic retinopathy. PMID:27994434

  17. Brazilian female crack users show elevated serum aluminum levels.

    PubMed

    Pechansky, Flavio; Kessler, Felix Henrique Paim; Diemen, Lisia von; Bumaguin, Daniela Benzano; Surratt, Hilary L; Inciardi, James A

    2007-03-01

    There is no information in the literature on the impact of crack smoking using crushed aluminum cans as makeshift pipes, a common form of crack use in Brazil. Since aluminum intake is associated with neurological damage, we measured serum aluminum levels in crack smokers. The objective of this study was to ascertain the levels of aluminum in crack users who smoke on makeshift aluminum pipes. 71 female crack smokers, their mean age being 28.0 (+/- 7.7), provided information about their drug use, and had blood samples tested for serum aluminum level. 56 (79%) subjects smoked crack from crushed can pipes, while 15 (21%) smoked from other containers. Fifty-two (73.2%) out of the 71 subjects presented a serum aluminum level of 2 microg/l and 13 (18.3%) had a serum aluminum level of 6 microg/l cut-off point, which is above the reference value. When compared to non-drug users matched by their mean age and gender, they had similar median values and interquartile ranges for serum aluminum level [3 (2-4.6) for crack smokers; 2.9 (1.6-4.1) for controls], but with different means and standard deviations (4.7 +/- 4.9 and 2.9 +/- 1.7, respectively). Crack smokers have high serum aluminum level, but we are unsure of its complete association with aluminum cans. Further studies are needed. If such association is proven true in future research, further issues will be raised in dealing with this important disorder, including proper planning and evaluation of public health policies in this area.

  18. Serum Cystatin C as an Early Diagnostic Biomarker of Diabetic Kidney Disease in Type 2 Diabetic Patients.

    PubMed

    Qamar, Ayesha; Hayat, Asma; Ahmad, Tariq Mahmood; Khan, Alamgir; Hasnat, Mohammad Najam Ul; Tahir, Sufyan

    2018-04-01

    To determine the diagnostic accuracy and cut-off values of serum cystatin C as early diagnostic biomarker of diabetic kidney disease. Cross-sectional analytical study. Department of Pathology, Army Medical College, Rawalpindi in collaboration with Endocrinology Department, Military Hospital (MH), Rawalpindi from November 2015 to November 2016. One hundred and nineteen diagnosed patients of type 2 diabetes mellitus were enrolled in the study from the outpatient Endocrinology Department of the MH Rawalpindi. Fifty disease-free controls were also included. Fasting blood samples of the patients and controls were analysed for creatinine by Jaffé's kinetic method and estimated GFR was calculated using MDRD-based equation for GFR. Serum cystatin C was estimated by quantitative turbidimetric method. Serum cystatin C was higher in the diabetic group (mean = 1.022 ±0.33 mg/dl) as compared to the control group (mean = 0.63 ±0.14 mg/dl). ROC curve analysis, keeping less than 60 ml/min/1.73 m2 GFR (CKD-MDRD based) as reference value of the stat variable/gold standard; revealed an area under the curve of 0.914 (95% CI 0.85-0.98) and at optimal sensitivity of 88.2% and specificity of 84.8% the established cut-off of serum cystatin C was 1.26 mg/L. Cystatin C is an accurate biomarker of diabetic kidney disease with good sensitivity and specificity.

  19. Serum PSA levels in the Indian population: Is it different?

    PubMed

    Agrawal, Amit; Karan, Shailesh Chandra

    2017-04-01

    Serum prostate-specific antigen (PSA) is an important tumour, marker which is widely used to trigger trans-rectal ultrasound (TRUS)-guided prostate biopsy. However, the PSA levels vary with race and ethnicity. Therefore, there is a need to have an Indian reference range. All adult male patients meeting the inclusion and exclusion criteria were enrolled in this study. They were subjected to assessment of serum total PSA, digital rectal examination and trans-abdominal ultrasound. If any one or more of these were found abnormal, then a TRUS-guided 12-core prostate biopsy was done. Patients who were detected to have prostatic cancer were excluded from the final analysis. The data so obtained was grouped among the following three age groups: 40-49, 50-59 and 60-70 years, and the age-specific PSA values, prostatic volume and PSA density were found. A total of 1772 patients were analysed. The mean serum total PSA was 1.76 ng/ml with a standard deviation of 2.566 ng/ml. Group-wise age distribution of the mean serum total PSA was 1.22, 1.97 and 2.08 ng/ml in 40-49, 50-59 and 60-70 years age groups. The mean total PSA and the age-specific PSA range tend to be lower in the Indians than the Western population.

  20. Raised serum lactate: a marker of necrotizing fasciitis?

    PubMed

    Murphy, George; Markeson, Daniel; Choa, Robert; Armstrong, Anthony

    2013-12-01

    Distinguishing necrotizing fasciitis from non-necrotizing soft-tissue infections remains a difficult clinical judgement call, with a paucity of diagnostic aids to the clinician. The aim of this study was to assess raised serum lactate as a point-of-care test to aid in differentiating necrotizing from non-necrotizing soft tissue infections. The authors performed a post-hoc analysis of a prospectively compiled database. All patients referred to a single surgeon (A.P.A.) as suspected cases of necrotizing fasciitis at one hospital between September 2000 and September 2010 were included. Serum lactate at presentation was recorded, along with demographic and outcome data. Using histological evidence of tissue necrosis as the 'gold standard', patients were divided into those with or without necrotizing fasciitis, and their serum lactate at presentation compared. Fifty three patients met the inclusion criteria. Twenty eight had histologically proven necrosis, 25 did not. Serum lactate (mean±SD) was 4.1±1.62 mmol/l in the necrotizing fasciitis group and 1.8±0.46 mmol/l in the non-necrotizing fasciitis group (p≤0.0001). A serum lactate level above 2.0 mmol/l had a sensitivity of 1.00 and a specificity of 0.76 for necrotizing fasciitis in this series. In this series of patients with suspected necrotizing soft tissue infection, serum lactate levels above 2.0 mmol/l at presentation were strongly associated with the presence of tissue necrosis. Although no test can be relied upon in isolation, our results suggest that serum lactate is a promising adjunct to the diagnosis of necrotizing infection, which could help to expedite appropriate management. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  1. Brix refractometry in serum as a measure of failure of passive transfer compared to measured immunoglobulin G and total protein by refractometry in serum from dairy calves.

    PubMed

    Hernandez, D; Nydam, D V; Godden, S M; Bristol, L S; Kryzer, A; Ranum, J; Schaefer, D

    2016-05-01

    A series of trials were conducted to evaluate Brix refractometry (Brix %) for the assessment of failure of passive transfer (FPT) in dairy calves compared to: (1) serum IgG (reference standard) when measured by radial immunodiffusion (RID) or a turbidometric immunoassay (TIA), and (2) serum total protein refractometry (STP). For the serum samples tested with TIA, STP, and Brix % (n = 310; Holstein calves), the median concentrations were 21.3 g/L IgG, 58 g/L STP, and 9.2%, respectively. For the serum samples tested with RID, STP and Brix % (n = 112; Jersey calves), the mean concentrations were 38 g/L IgG, 68 g/L STP, and 10.2%, respectively. For samples tested with only Brix % and STP (n = 265; Holstein calves), median STP and Brix % were 50 g/L STP and 8.5%, respectively. Correlations between Brix % and RID, and between Brix % and TIA were equal (r = 0.79, respectively). Brix % and STP were positively correlated (r = 0.99). Brix % estimated serum IgG concentrations determined by TIA and RID (r(2) = 0.63, 0.62, respectively). When FPT was defined as serum IgG < 10 g/L, Brix % ≤ 8.5% showed optimal sensitivity (100%) and specificity (89.2%) to predict FPT. At the same IgG cut-point, an STP value of ≤ 52 g/L showed a similar sensitivity (100%) and specificity (80.4%) to predict FPT. Brix refractometry predicted successful transfer of passive immunity in dairy calves, but further evaluation as a diagnostic tool for the diagnosis of FPT is warranted. Copyright © 2016. Published by Elsevier Ltd.

  2. Performance evaluation of the HepB Typer-Entecavir kit for detection of entecavir resistance mutations in chronic hepatitis B.

    PubMed

    Ahn, Sang Hoon; Chun, Ji-Yong; Shin, Soo-Kyung; Park, Jun Yong; Yoo, Wangdon; Hong, Sun Pyo; Kim, Soo-Ok; Han, Kwang-Hyub

    2013-12-01

    Molecular diagnostic methods have enabled the rapid diagnosis of drug-resistant mutations in hepatitis B virus (HBV) and have reduced both unnecessary therapeutic interventions and medical costs. In this study we evaluated the analytical and clinical performances of the HepB Typer-Entecavir kit (GeneMatrix, Korea) in detecting entecavir-resistance-associated mutations. The HepB Typer-Entecavir kit was evaluated for its limit of detection, interference, cross-reactivity, and precision using HBV reference standards made by diluting high-titer viral stocks in HBV-negative human serum. The performance of the HepB Typer-Entecavir kit for detecting mutations related to entecavir resistance was compared with direct sequencing for 396 clinical samples from 108 patients. Using the reference standards, the detection limit of the HepB Typer-Entecavir kit was found to be as low as 500 copies/mL. No cross-reactivity was observed, and elevated levels of various interfering substances did not adversely affect its analytical performance. The precision test conducted by repetitive analysis of 2,400 replicates with reference standards at various concentrations showed 99.9% agreement (2398/2400). The overall concordance rate between the HepB Typer-Entecavir kit and direct sequencing assays in 396 clinical samples was 99.5%. The HepB Typer-Entecavir kit showed high reliability and precision, and comparable sensitivity and specificity for detecting mutant virus populations in reference and clinical samples in comparison with direct sequencing. Therefore, this assay would be clinically useful in the diagnosis of entecavir-resistance-associated mutations in chronic hepatitis B.

  3. Serum bicarbonate and mortality in adults in NHANES III

    PubMed Central

    Raphael, Kalani L.; Zhang, Yingying; Wei, Guo; Greene, Tom; Cheung, Alfred K.; Beddhu, Srinivasan

    2013-01-01

    Background Low serum bicarbonate concentration is a risk factor for death in people with chronic kidney disease (CKD). Whether low serum bicarbonate is a mortality risk factor for people without CKD is unknown. Methods National Health and Nutrition Examination Survey III (NHANES III) adult participants were categorized into one of four serum bicarbonate categories: <22, 22–25, 26–30 and ≥31 mM. Cox models were used to determine the hazards of death in each serum bicarbonate category, using 26–30 mM as the reference group, in the (i) entire population, (ii) non-CKD subgroup and (iii) CKD subgroup. Results After adjusting for age, gender, race, estimated glomerular filtration rate, albuminuria, diuretic use, smoking, C-reactive protein, cardiovascular disease, protein intake, diabetes, hypertension, body mass index, lung disease and serum albumin, the hazards of death in the <22 mM serum bicarbonate category were 1.75 (95% CI: 1.12–2.74), 1.56 (95% CI: 0.78–3.09) and 2.56 (95% CI: 1.49–4.38) in the entire population, non-CKD subgroup and CKD subgroup, respectively, compared with the reference group. Hazard ratios in the other serum bicarbonate categories in the entire population and non-CKD and CKD subgroups did not differ from the reference group. Conclusions Among the NHANES III participants, low serum bicarbonate was not observed to be a strong predictor of mortality in people without CKD. However, low serum bicarbonate was associated with a 2.6-fold increased hazard of death in people with CKD. PMID:23348878

  4. [Treatment of primary hypothyroidism in adult patients].

    PubMed

    Salmela, Pasi; Metso, Saara; Moilanen, Leena; Niskanen, Leo; Nuutila, Pirjo; Schalin-Jäntti, Camilla

    2016-01-01

    The diagnosis of hypothyroidism is based on the findings of an increased serum TSH (above the reference range) and decreased serum free T4 (below the reference range) concentration. Treatment of subclinical hypothyroidism is indicated if serum THS is above 10 mU/l. For less severe forms of subclinical hypothyroidism, the treatment should be individually tailored. The treatment of choice is synthetic human levothyroxine. The goals for treatment are amelioration of symptoms and normalization of TSH and free T4 concentrations.

  5. Normal reference intervals and the effects of time and feeding on serum bile acid concentrations in llamas.

    PubMed

    Andreasen, C B; Pearson, E G; Smith, B B; Gerros, T C; Lassen, E D

    1998-04-01

    Fifty clinically healthy llamas, 0.5-13 years of age (22 intact males, 10 neutered males, 18 females), with no biochemical evidence of liver disease or hematologic abnormalities, were selected to establish serum bile acid reference intervals. Serum samples submitted to the clinical pathology laboratory were analyzed using a colorimetric enzymatic assay to establish bile acid reference intervals. A nonparametric distribution of llama bile acid concentrations was 1-23 micromol/liter for llamas >1 year of age and 10-44 micromol/liter for llamas < or = 1 year of age. A significant difference was found between these 2 age groups. No correlation was detected between gender and bile acid concentrations. The reference intervals were 1.1-22.9 micromol/liter for llamas >1 year of age and 1.8-49.8 micromol/liter for llamas < or = 1 year of age. Additionally, a separate group of 10 healthy adult llamas (5 males, 5 females, 5-11 years of age) without biochemical or hematologic abnormalities was selected to assess the effects of feeding and time intervals on serum bile acid concentrations. These 10 llamas were provided fresh water and hay ad libitum, and serum samples were obtained via an indwelling jugular catheter hourly for 11 hours. Llamas were then kept from food overnight (12 hours), and subsequent samples were taken prior to feeding (fasting baseline time, 23 hours after trial initiation) and postprandially at 0.5, 1, 2, 4, and 8 hours. In feeding trials, there was no consistent interaction between bile acid concentrations and time, feeding, or 12-hour fasting. Prior feeding or time of day did not result in serum bile acid concentrations outside the reference interval, but concentrations from individual llamas varied within this interval over time.

  6. Cure of tuberculosis despite serum concentrations of antituberculosis drugs below published reference ranges.

    PubMed

    Meloni, Monica; Corti, Natascia; Müller, Daniel; Henning, Lars; Gutteck, Ursula; von Braun, Amrei; Weber, Rainer; Fehr, Jan

    2015-01-01

    Therapeutic target serum concentrations of first-line antituberculosis drugs have not been well defined in clinical studies in tuberculosis (TB) patients. We retrospectively investigated the estimated maximum serum concentrations (eC max) of antituberculosis drugs and clinical outcome of TB patients with therapeutic drug monitoring performed between 2010-2012 at our institution, and follow-up until March 2014. The eC max was defined as the highest serum concentration during a sampling period (2, 4 and 6 hours after drug ingestion). We compared the results with published eC max values, and categorised them as either "within reference range", "low eC max", or "very low eC max".Low/very low eC max-levels were defined as follows: isoniazid 2-3/<2 mg/l, rifampicin 4-8/<4 mg/l, rifabutin 0.2-0.3/<0.2 mg/l, ethambutol 1-2/<0.1 mg/l and pyrazinamide <20 mg/l. Concentrations of antituberculosis drugs in 175 serum samples of 17 patients with TB were analysed. In 12 (71%) patients, multiple therapeutic drug monitoring samples were collected over time, in 5 (29%) patients only one sample was available for therapeutic drug monitoring. Overall, 94% of all patients had at least one low antituberculosis drug concentration. Overall, 64% of all eC max levels were classified as "low" or "very low". The eC max was below the relevant reference range in 80% of isoniazid, 95% of rifampicin, 30% of pyrazinamide, and 30% of ethambutol measurements. All but one patient were cured of tuberculosis. Although many antituberculosis drug serum concentrations were below the widely used reference ranges, 16 of 17 patients were cured of tuberculosis. These results challenge the use of the published reference ranges for therapeutic drug monitoring.

  7. Perspective: The Case for an Evidence-Based Reference Interval for Serum Magnesium: The Time Has Come.

    PubMed

    Costello, Rebecca B; Elin, Ronald J; Rosanoff, Andrea; Wallace, Taylor C; Guerrero-Romero, Fernando; Hruby, Adela; Lutsey, Pamela L; Nielsen, Forrest H; Rodriguez-Moran, Martha; Song, Yiqing; Van Horn, Linda V

    2016-11-01

    The 2015 Dietary Guidelines Advisory Committee indicated that magnesium was a shortfall nutrient that was underconsumed relative to the Estimated Average Requirement (EAR) for many Americans. Approximately 50% of Americans consume less than the EAR for magnesium, and some age groups consume substantially less. A growing body of literature from animal, epidemiologic, and clinical studies has demonstrated a varied pathologic role for magnesium deficiency that includes electrolyte, neurologic, musculoskeletal, and inflammatory disorders; osteoporosis; hypertension; cardiovascular diseases; metabolic syndrome; and diabetes. Studies have also demonstrated that magnesium deficiency is associated with several chronic diseases and that a reduced risk of these diseases is observed with higher magnesium intake or supplementation. Subclinical magnesium deficiency can exist despite the presentation of a normal status as defined within the current serum magnesium reference interval of 0.75-0.95 mmol/L. This reference interval was derived from data from NHANES I (1974), which was based on the distribution of serum magnesium in a normal population rather than clinical outcomes. What is needed is an evidenced-based serum magnesium reference interval that reflects optimal health and the current food environment and population. We present herein data from an array of scientific studies to support the perspective that subclinical deficiencies in magnesium exist, that they contribute to several chronic diseases, and that adopting a revised serum magnesium reference interval would improve clinical care and public health. © 2016 American Society for Nutrition.

  8. Perspective: The Case for an Evidence-Based Reference Interval for Serum Magnesium: The Time Has Come12345

    PubMed Central

    Elin, Ronald J; Rosanoff, Andrea; Lutsey, Pamela L; Nielsen, Forrest H; Rodriguez-Moran, Martha

    2016-01-01

    The 2015 Dietary Guidelines Advisory Committee indicated that magnesium was a shortfall nutrient that was underconsumed relative to the Estimated Average Requirement (EAR) for many Americans. Approximately 50% of Americans consume less than the EAR for magnesium, and some age groups consume substantially less. A growing body of literature from animal, epidemiologic, and clinical studies has demonstrated a varied pathologic role for magnesium deficiency that includes electrolyte, neurologic, musculoskeletal, and inflammatory disorders; osteoporosis; hypertension; cardiovascular diseases; metabolic syndrome; and diabetes. Studies have also demonstrated that magnesium deficiency is associated with several chronic diseases and that a reduced risk of these diseases is observed with higher magnesium intake or supplementation. Subclinical magnesium deficiency can exist despite the presentation of a normal status as defined within the current serum magnesium reference interval of 0.75–0.95 mmol/L. This reference interval was derived from data from NHANES I (1974), which was based on the distribution of serum magnesium in a normal population rather than clinical outcomes. What is needed is an evidenced-based serum magnesium reference interval that reflects optimal health and the current food environment and population. We present herein data from an array of scientific studies to support the perspective that subclinical deficiencies in magnesium exist, that they contribute to several chronic diseases, and that adopting a revised serum magnesium reference interval would improve clinical care and public health. PMID:28140318

  9. Effect of 25(OH) vitamin D reference method procedure (RMP) alignment on clinical measurements obtained with the IDS-iSYS chemiluminescent-based automated analyzer.

    PubMed

    Simpson, Christine A; Cusano, Anna Maria; Bihuniak, Jessica; Walker, Joanne; Insogna, Karl L

    2015-04-01

    The Vitamin D Standardization Program (VDSP) has identified ID-LC/MS/MS as the reference method procedure (RMP) for 25(OH) vitamin D and NIST Standard SRM2972 as the standard reference material (SRM). As manufacturers align their products to the RMP and NIST standard, a concern is that results obtained in aligned assays will be divergent from those obtained with pre-alignment assays. The Immunodiagnostic Systems Ltd., chemiluminescent, 25(OH) vitamin D iSYS platform assay, was recently harmonized to the RMP. To determine the impact of standardization on results obtained with iSYS reagents, 119 single donor serum samples from eight different disease categories were analyzed in four non-standardized and two standardized iSYS assays. There were strong correlations between the four non-standardized and two standardized assays with Spearman's rank r values between 0.975 and 0.961 and four of the eight r values were >0.97. R(2) values for the eight best-fit linear regression equations ranging between 0.947 and 0.916. None of the slopes were found to be significantly different from one another. Bland-Altman plots showed that the bias was comparable when each of the four non-standardized assays was compared to either of the standardized assays. When the data were segregated in values between 6 and 49ng/mL (15-122nmol/L) or between 50 and 100ng/mL (125-250nmol/L) significant associations remained between results obtained with non-standardized and standardized calibrators regardless of the absolute value. When five recent DEQAS unknowns were analyzed in one non-standardized and one standardized assay the mean percent difference from the NIST target in values obtained using standardized vs. non-standardized calibrators were not significantly different. Finally, strong and statistically significant associations between the results were obtained using non-standardized and standardized assays for six of eight clinical conditions. The only exceptions were hypocalcemia and breast cancer, which likely reflect the small sample sizes for each of these diseases. These initial data provide confidence that the move to a NIST standardized assay will have little impact on results obtained with the iSYS platform. This article is part of a Special Issue entitled '17th Vitamin D Workshop'. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Identification of Reliable Reference Genes for Quantification of MicroRNAs in Serum Samples of Sulfur Mustard-Exposed Veterans.

    PubMed

    Gharbi, Sedigheh; Shamsara, Mehdi; Khateri, Shahriar; Soroush, Mohammad Reza; Ghorbanmehr, Nassim; Tavallaei, Mahmood; Nourani, Mohammad Reza; Mowla, Seyed Javad

    2015-01-01

    In spite of accumulating information about pathological aspects of sulfur mustard (SM), the precise mechanism responsible for its effects is not well understood. Circulating microRNAs (miRNAs) are promising biomarkers for disease diagnosis and prognosis. Accurate normalization using appropriate reference genes, is a critical step in miRNA expression studies. In this study, we aimed to identify appropriate reference gene for microRNA quantification in serum samples of SM victims. In this case and control experimental study, using quantitative real-time polymerase chain reaction (qRT-PCR), we evaluated the suitability of a panel of small RNAs including SNORD38B, SNORD49A, U6, 5S rRNA, miR-423-3p, miR-191, miR-16 and miR-103 in sera of 28 SM-exposed veterans of Iran-Iraq war (1980-1988) and 15 matched control volunteers. Different statistical algorithms including geNorm, Normfinder, best-keeper and comparative delta-quantification cycle (Cq) method were employed to find the least variable reference gene. miR-423-3p was identified as the most stably expressed reference gene, and miR- 103 and miR-16 ranked after that. We demonstrate that non-miRNA reference genes have the least stabil- ity in serum samples and that some house-keeping miRNAs may be used as more reliable reference genes for miRNAs in serum. In addition, using the geometric mean of two reference genes could increase the reliability of the normalizers.

  11. Management of gout by UK rheumatologists: a British Society for Rheumatology national audit.

    PubMed

    Roddy, Edward; Packham, Jon; Obrenovic, Karen; Rivett, Ali; Ledingham, Joanna M

    2018-05-01

    To assess the concordance of gout management by UK rheumatologists with evidence-based best-practice recommendations. Data were collected on patients newly referred to UK rheumatology out-patient departments over an 8-week period. Baseline data included demographics, method of diagnosis, clinical features, comorbidities, urate-lowering therapy (ULT), prophylaxis and blood tests. Twelve months later, the most recent serum uric acid level was collected. Management was compared with audit standards derived from the 2006 EULAR recommendations, 2007 British Society for Rheumatology/British Health Professionals in Rheumatology guideline and the National Institute for Health and Care Excellence febuxostat technology appraisal. Data were collected for 434 patients from 91 rheumatology departments (mean age 59.8 years, 82% male). Diagnosis was crystal-proven in 13%. Of 106 taking a diuretic, this was reduced/stopped in 29%. ULT was continued/initiated in 76% of those with one or more indication for ULT. One hundred and fifty-eight patients started allopurinol: the starting dose was most commonly 100 mg daily (82%); in those with estimated glomerular filtration rate <60 ml/min the highest starting dose was 100 mg daily. Of 199 who started ULT, prophylaxis was co-prescribed for 94%. Fifty patients started a uricosuric or febuxostat: 84% had taken allopurinol previously. Of 44 commenced on febuxostat, 18% had a history of heart disease. By 12 months, serum uric acid levels ⩽360 and <300 μmol/l were achieved by 45 and 25%, respectively. Gout management by UK rheumatologists concords well with guidelines for most audit standards. However, fewer than half of patients achieved a target serum uric level over 12 months. Rheumatologists should help ensure that ULT is optimized to achieve target serum uric acid levels to benefit patients.

  12. Serum TSH reference interval in healthy Finnish adults using the Abbott Architect 2000i Analyzer.

    PubMed

    Schalin-Jäntti, Camilla; Tanner, Pirjo; Välimäki, Matti J; Hämäläinen, Esa

    2011-07-01

    Current serum TSH reference intervals have been criticized as they were established from unselected background populations. A special concern is that the upper limit, which defines subclinical hypothyroidism, is too high. The objective was to redefine the TSH reference interval in the adult Finnish population. The current reference interval for the widely used Abbott Architect method in Finland is 0.4-4.0 mU/L. Serum TSH and free T4 concentrations were derived from 606 healthy, non-pregnant, 18-91-year-old Finns from the Nordic Reference Interval Project (NORIP) and the possible effects of age, sex and thyroid peroxidase antibody (TPOAb) status were evaluated. After excluding TPOAb-positive subjects and outliers, a reference population of 511 subjects was obtained. In the reference population, no statistically significant gender- or age-specific differences in mean TSH (1.55 ± 3.30 mU/L) or TSH reference intervals were observed. The new reference interval was 0.5-3.6 mU/L (2.5th-97.5th percentiles). The current upper TSH reference limit is 10% too high. A TSH > 3.6 mU/L, confirmed with a repeat TSH sampling, may indicate subclinical hypothyroidism. Differences in ethnicity, regional iodine-intake and analytical methods underline the need for redefining the TSH reference interval in central laboratories in different countries.

  13. Credibility of the measurement of serum ferritin and transferrin receptor as indicators of iron deficiency anemia in hemodialysis patients.

    PubMed

    Mahdavi, M R; Makhlough, A; Kosaryan, M; Roshan, P

    2011-10-01

    Anemia is a common complication in uremic patients. Erythropoietin therapy is prescribed in these cases; however, this treatment is not successful in iron deficient patients. Ferritin-based diagnosis of iron deficiency in these patients is a challenging task, as serum ferritin level may be high due to chronic inflammation and mask iron deficiency. In the current study we evaluated the credibility of another indicator of body iron supply, serum transferrin receptor, in hemodialysis patients in two University-based Hospitals in North of Iran. In a cross-sectional study, 53 hemodialysis patients with a mean age of 56 +/- 18.7 years and 30 persons with iron deficiency and normal renal function with a mean age of 20.1 +/- 14.4 years were examined. All hemodialysis patients were on hemodialysis 2-3 times per week for 3-4 hours. All cases were examined for blood hemoglobin content, serum iron, CRP, serum ferritin and serum transferrin receptor levels. The reference ranges introduced by manufacturers were considered as standard ranges for analysis of the results. Using one sample T-test and Fisher's exact test, data were analyzed. p<0.05 was considered as significant. Hemodialysis patients had blood hemoglobin content below normal range (p<0.05 for men, p<0.001 for women) and CRP levels above normal range (p<0.001). In hemodialysis patients, serum ferritin level was significantly higher than control group (p<0.001), whilst serum transferrin receptor levels in the two groups were not significantly different (p=0.69), and both were above defined normal upper limit (p<0.001 for iron deficient patients; p<0.05 for hemodialysis patients). This study showed measurement of serum ferritin in the presence of chronic inflammation induced by renal failure cannot be a credible indicator of body iron supply, while under this certain condition serum transferrin receptor can more appropriately reflect the amount of body iron supply.

  14. Serum reference interval of ARCHITECT alpha-fetoprotein in healthy Chinese Han adults: Sub-analysis of a prospective multi-center study.

    PubMed

    Yan, Cunling; Yang, Jia; Wei, Lianhua; Hu, Jian; Song, Jiaqi; Wang, Xiaoqin; Han, Ruilin; Huang, Ying; Zhang, Wei; Soh, Andrew; Beshiri, Agim; Fan, Zhuping; Zheng, Yijie; Chen, Wei

    2018-02-01

    Alpha-fetoprotein (AFP) has been widely used in clinical practice for decades. However, large-scale survey of serum reference interval for ARCHITECT AFP is still absent in Chinese population. This study aimed to measure serum AFP levels in healthy Chinese Han subjects, which is a sub-analysis of an ongoing prospective, cross-sectional, multi-center study (ClinicalTrials.gov Identifier: NCT03047603). This analysis included a total of 530 participants (41.43±12.14years of age on average, 48.49% males), enrolled from 5 regional centers. Serum AFP level was measured by ARCHITECT immunoassay. Statistical analysis was performed using SAS 9.4 and R software. AFP distribution did not show significant correlation with age or sex. The overall median and interquartile range of AFP was 2.87 (2.09, 3.83) ng/mL. AFP level did not show a trend of increasing with age. The new reference interval was 2.0-7.07ng/mL (LOQ- 97.5th percentiles). The reference interval for ARCHITECT AFP is updated with the data of adequate number of healthy Han adults. This new reference interval is more practical and applicable in Chinese adults. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  15. Roles of circulating WNT-signaling proteins and WNT-inhibitors in human adiposity, insulin resistance, insulin secretion, and inflammation.

    PubMed

    Almario, R U; Karakas, S E

    2015-02-01

    Wingless-type MMTV integration site family member (WNT) signaling and WNT-inhibitors have been implicated in regulation of adipogenesis, insulin resistance, pancreatic function, and inflammation. Our goal was to determine serum proteins involved in WNT signaling (WNT5 and WISP2) and WNT inhibition (SFRP4 and SFRP5) as they relate to obesity, serum adipokines, insulin resistance, insulin secretion, and inflammation in humans. Study population comprised 57 insulin resistant women with polycystic ovary syndrome (PCOS) and 27 reference women. In a cross-sectional study, blood samples were obtained at fasting, during oral, and frequently sampled intravenous glucose tolerance tests. Serum WNT5, WISP2, and SFRP4 concentrations did not differ between PCOS vs. reference women. Serum WNT5 correlated inversely with weight both in PCOS and reference women, and correlated directly with insulin response during oral glucose tolerance test in PCOS women. Serum WISP2 correlated directly with fatty acid binding protein 4. Serum SFRP5 did not differ between obese (n=32) vs. nonobese (n=25) PCOS women, but reference women had lower SFRP5 (p<5×10(-6) as compared to both PCOS groups). Serum SFRP5 correlated inversely with IL-1β, TNF-α, cholesterol, and apoprotein B. These findings demonstrated that WNT5 correlated inversely with adiposity and directly with insulin response, and the WNT-inhibitor SFRP5 may be anti-inflammatory. Better understanding of the role of WNT signaling in obesity, insulin resistance, insulin secretion, lipoprotein metabolism, and inflammation is important for prevention and treatment of metabolic syndrome, diabetes and cardiovascular disease. © Georg Thieme Verlag KG Stuttgart · New York.

  16. Correlation of serum androgens and pituitary hormone levels with serum PSA less than 2.5 ng/ml.

    PubMed

    Sofikerim, Mustafa; Oruç, Ozgür; Eskicorapci, Sadettin; Guliyev, Fuat; Ozen, Haluk

    2007-07-27

    The aim of this clinical study was to determine whether there is a relationship between total serum testosterone, free testosterone, FSH (Follicle-Stimulating Hormone), LH (Luteinizing Hormone) and serum prostate specific antigen (PSA) levels. We postulated that such a correlation existed then the use of hormone specific reference ranges might enhance the usefullness of PSA concentrations <2.5 ng/mL as a marker for prostate cancer. Prior to digital rectal examination, serum was obtained from all patients between 8.30-10:00 AM for hormone and PSA concentrations. The study was performed on 210 male patients >40 years of age visiting our urology outpatient clinics. PSA was correlated to age (r = 0.23, p = 0.019), but there none between serum testosterone and age. No significant correlation was noted between testosterone or free testosterone and serum PSA levels, and none between serum FSH or LH and PSA. In age specific reference groups (41-49; 50-59; 60-69 years), we found no significant correlation between PSA and hormone concentrations. In this population of eugonadal men with serum PSA values less than 2.5 ng/ml, serum androgens and pituitary hormones do not appear to correlate with serum PSA.

  17. Association between serum selenium level and conversion of bacteriological tests during antituberculosis treatment* **

    PubMed Central

    de Moraes, Milena Lima; Ramalho, Daniela Maria de Paula; Delogo, Karina Neves; Miranda, Pryscila Fernandes Campino; Mesquita, Eliene Denites Duarte; de Oliveira, Hedi Marinho de Melo Guedes; Ruffino-Netto, Antônio; de Almeida, Paulo César; Hauser-Davis, Rachel Ann; Campos, Reinaldo Calixto; Kritski, Afrânio Lineu; de Oliveira, Martha Maria

    2014-01-01

    Objective: To determine whether serum selenium levels are associated with the conversion of bacteriological tests in patients diagnosed with active pulmonary tuberculosis after eight weeks of standard treatment. Methods: We evaluated 35 healthy male controls and 35 male patients with pulmonary tuberculosis, the latter being evaluated at baseline, as well as at 30 and 60 days of antituberculosis treatment. For all participants, we measured anthropometric indices, as well as determining serum levels of albumin, C-reactive protein (CRP) and selenium. Because there are no reference values for the Brazilian population, we used the median of the serum selenium level of the controls as the cut-off point. At 30 and 60 days of antituberculosis treatment, we repeated the biochemical tests, as well as collecting sputum for smear microscopy and culture from the patients. Results: The mean age of the patients was 38.4 ± 11.4 years. Of the 35 patients, 25 (71%) described themselves as alcoholic; 20 (57.0%) were smokers; and 21 (60.0%) and 32 (91.4%) presented with muscle mass depletion as determined by measuring the triceps skinfold thickness and arm muscle area, respectively. Of 24 patients, 12 (39.2%) were classified as moderately or severely emaciated, and 15 (62.5%) had lost > 10% of their body weight by six months before diagnosis. At baseline, the tuberculosis group had lower serum selenium levels than did the control group. The conversion of bacteriological tests was associated with the CRP/albumin ratio and serum selenium levels 60 days after treatment initiation. Conclusions: Higher serum selenium levels after 60 days of treatment were associated with the conversion of bacteriological tests in pulmonary tuberculosis patients. PMID:25029650

  18. Association between serum selenium level and conversion of bacteriological tests during antituberculosis treatment.

    PubMed

    Moraes, Milena Lima de; Ramalho, Daniela Maria de Paula; Delogo, Karina Neves; Miranda, Pryscila Fernandes Campino; Mesquita, Eliene Denites Duarte; Oliveira, Hedi Marinho de Melo Guedes de; Ruffino-Netto, Antônio; Almeida, Paulo César de; Hauser-Davis, Rachel Ann; Campos, Reinaldo Calixto; Kritski, Afrânio Lineu; Oliveira, Martha Maria de

    2014-01-01

    To determine whether serum selenium levels are associated with the conversion of bacteriological tests in patients diagnosed with active pulmonary tuberculosis after eight weeks of standard treatment. We evaluated 35 healthy male controls and 35 male patients with pulmonary tuberculosis, the latter being evaluated at baseline, as well as at 30 and 60 days of antituberculosis treatment. For all participants, we measured anthropometric indices, as well as determining serum levels of albumin, C-reactive protein (CRP) and selenium. Because there are no reference values for the Brazilian population, we used the median of the serum selenium level of the controls as the cut-off point. At 30 and 60 days of antituberculosis treatment, we repeated the biochemical tests, as well as collecting sputum for smear microscopy and culture from the patients. The mean age of the patients was 38.4 ± 11.4 years. Of the 35 patients, 25 (71%) described themselves as alcoholic; 20 (57.0%) were smokers; and 21 (60.0%) and 32 (91.4%) presented with muscle mass depletion as determined by measuring the triceps skinfold thickness and arm muscle area, respectively. Of 24 patients, 12 (39.2%) were classified as moderately or severely emaciated, and 15 (62.5%) had lost > 10% of their body weight by six months before diagnosis. At baseline, the tuberculosis group had lower serum selenium levels than did the control group. The conversion of bacteriological tests was associated with the CRP/albumin ratio and serum selenium levels 60 days after treatment initiation. Higher serum selenium levels after 60 days of treatment were associated with the conversion of bacteriological tests in pulmonary tuberculosis patients.

  19. The gallium melting-point standard: its application and evaluation for temperature measurements in the clinical laboratory.

    PubMed

    Bowers, G N; Inman, S R

    1977-01-01

    We are impressed with the ease and certainty of calibration electronic thermometers with thermistor probes to +/- 0.01 degree C at the gallium melting point, 29.771(4) degrees C. The IFCC reference method for measuring aspartate aminotransferase activity in serum was run at the reaction temperature of 29.771(4) degrees C. By constantly referencing to gallium as an integral part of the assay procedure, we determined the absolute reaction temperature to IPTS-68 (International Practical Temperature Scale of 1968) to +/- 0.02 degrees C. This unique temperature calibration standard near the center of the range of temperatures commonly used in the clinical laboratory is a valuable addition and can be expected to improve the accuracy of measurements, especially in clinical enzymology.

  20. Serum PCB levels and congener profiles among US construction workers

    PubMed Central

    Herrick, Robert F; Meeker, John D; Hauser, Russ; Altshul, Larisa; Weymouth, George A

    2007-01-01

    Background The presence of PCB in caulking (sealant) material found in masonry buildings has been well-documented in several countries. A recent investigation of 24 buildings in the greater Boston area found that 8 buildings had high PCB levels in caulking materials used around window frames and in joints between masonry blocks. Workers removing caulking material have been shown to have elevated serum PCB levels. Methods This project compared serum PCB levels among male workers who installed and/or removed PCB-containing caulking material from buildings in the greater Boston area with reference serum PCB levels from 358 men from the same area. Serum PCB levels were measured in the same laboratory by liquid-liquid extraction, column chromatography clean-up and dual capillary column GC/microECD analysis. Results When the congener profiles were compared between the reference population and the construction workers, the serum levels of the more volatile, lighter PCBs (di-, tri-and tetrachloro, sum of IUPAC# 6–74) were substantially higher among the construction workers. One of the youngest workers had the lowest total serum PCB levels (sum of 57 congeners) of all 6 workers, but the contribution of more volatile (less chlorinated) PCB congeners (#16, 26,28,33,74,66, and 60) was markedly higher than in other 5 workers and reference men. Only this worker was working on a job that involved removing PCB caulking at the time of the blood sampling. Conclusion While the results of this pilot study are based upon small numbers (6 construction workers who handled PCB caulking), the serum PCB levels among the construction workers exceed the referents. Comparison of the congener profiles suggests that there are substantial differences between the construction workers and the general population samples. These differences, and the similarities of profiles among the construction workers strongly suggest that occupational contact with caulking material can be a major source of PCB exposure for construction workers. PMID:17764566

  1. Serum chemistry of free-ranging white whales (Delphinapterus leucas) in Svalbard.

    PubMed

    Tryland, Morten; Thoresen, Stein Istre; Kovacs, Kit M; Lydersen, Christian

    2006-06-01

    Abnormal physiological conditions and diseases can change the concentrations of enzymes, metabolites, and minerals in the body. Serum chemistry information may thus be indicative of a specific disease; interpretation of such information requires knowledge of serum chemistry reference intervals from a seemingly healthy population of the species. The aim of this study was to obtain serum chemistry reference intervals for a population of white whales. Blood samples were collected from 21 free-ranging white whales (beluga; Delphinapterus leucas). The whales were live-captured in nets during 1996-2001 in Storfjorden, Van Mijenfjorden, and Van Keulenfjorden (Svalbard, Norway). While the whales were briefly physically restrained, blood was collected from the caudal vein into vacuum tubes without anticoagulant. The blood was left to clot for 4-6 hours before serum was obtained by centrifugation. The serum samples were then kept at -20 degrees C until analysis. Enzymes (aspartate aminotransferase, alanine aminotransferase, alkaline phosphatase [ALP], creatine kinase, lactate dehydrogenase [LDH], amylase, lipase), metabolites (urea, creatinine, bilirubin, cholesterol, triglycerides, nonesterified fatty acids, glucose), and minerals (calcium, phosphate, magnesium, sodium, potassium, chloride) were analyzed in an Advia 1650 System (Bayer, Tarrytown, NY, USA). Cortisol was analyzed in an Immulite One system (Diagnostic Products Corporation, Los Angeles, CA, USA). The major blood proteins (albumin and globulins) were separated by gel electrophoresis in a Beckman Paragon electrophoresis system (Beckman Coulter, Inc., Fullerton, CA, USA). Serum values for all analytes were reported as median and range, and reference intervals were calculated as 10-90th percentiles. Activities of ALP and LDH and cortisol concentration were higher, and protein and bilirubin concentrations were lower compared with those previously reported for white whales from Canada; remaining results were strikingly similar in these 2 white whale populations. These data provide valuable serum chemistry reference intervals for future health assessments of white whales in Svalbard and other white whale populations, as well as captive individuals.

  2. Interlaboratory ring trial to evaluate CFT proficiency of European laboratories for diagnosis of glanders in equids.

    PubMed

    Laroucau, K; Colaneri, C; Jaÿ, M; Corde, Y; Drapeau, A; Durand, B; Zientara, S; Beck, C

    2016-06-18

    To evaluate the routine complement fixation test (CFT) used to detect Burkholderia mallei antibodies in equine sera, an interlaboratory proficiency test was held with 24 European laboratories, including 22 National Reference Laboratories for glanders. The panels sent to participants were composed of sera with or without B mallei antibodies. This study confirmed the reliability of CFT and highlighted its intralaboratory reproducibility. However, the sensitivity of glanders serodiagnosis and laboratory proficiency may be improved by standardising critical reagents, including antigens, and by developing a standard B mallei serum. British Veterinary Association.

  3. Respiratory alkalosis and associated electrolytes in long-term ventilator dependent persons with tetraplegia.

    PubMed

    Watt, J W; Silva, P

    2001-11-01

    A pilot case control study of the acid-base and electrolyte status in 30 long-term ventilator-dependent (LTVD) and 30 self ventilating persons with tetraplegia. To assess the extent of respiratory alkalosis and screen for associated hypokalaemia, hypomagnesaemia and/or hypophosphataemia. Medically stable persons with tetraplegia under the long-term care of the Southport Spinal Injuries Centre, England. Blood gases and electrolytes were sampled from 30 control patients with tetraplegia and from 30 patients having been LTVD for more than 12 months. All the blood gas measurements in the LTVD group lay outside both the reference range and the 95% confidence intervals (CI) of the control group: pH 7.46 (0.06); PCO(2) 3.46 (1.1) kPa; bicarbonate 18.3 (3.8) and base excess -3.2 (2.8) mmol/l; PO(2) 13.8 (2.8) kPa (means and standard deviations). The serum potassium, magnesium, phosphate, and sodium means lay within the reference ranges but the potassium, phosphate and calcium were at or below the 95% CI of the control values. One patient on part-time ventilatory support having less bicarbonate compensation had low serum electrolytes during ventilation. There was no evidence of biochemical jeopardy from long-term mechanical hyperventilation although acutely administered hyperventilation has the potential to cause falls in serum potassium, magnesium and phosphate and so caution should be exercised in part-time ventilated persons. The full range of electrolytes should be assayed during stabilisation in LTVD and periodically thereafter. Hyperventilation helps to maintain good oxygenation in LTVD persons with paralysis and normal lungs. None.

  4. Performance evaluation of the HepB Typer-Entecavir kit for detection of entecavir resistance mutations in chronic hepatitis B

    PubMed Central

    Ahn, Sang Hoon; Chun, Ji-Yong; Shin, Soo-Kyung; Park, Jun Yong; Yoo, Wangdon; Hong, Sun Pyo; Han, Kwang-Hyub

    2013-01-01

    Background/Aims Molecular diagnostic methods have enabled the rapid diagnosis of drug-resistant mutations in hepatitis B virus (HBV) and have reduced both unnecessary therapeutic interventions and medical costs. In this study we evaluated the analytical and clinical performances of the HepB Typer-Entecavir kit (GeneMatrix, Korea) in detecting entecavir-resistance-associated mutations. Methods The HepB Typer-Entecavir kit was evaluated for its limit of detection, interference, cross-reactivity, and precision using HBV reference standards made by diluting high-titer viral stocks in HBV-negative human serum. The performance of the HepB Typer-Entecavir kit for detecting mutations related to entecavir resistance was compared with direct sequencing for 396 clinical samples from 108 patients. Results Using the reference standards, the detection limit of the HepB Typer-Entecavir kit was found to be as low as 500 copies/mL. No cross-reactivity was observed, and elevated levels of various interfering substances did not adversely affect its analytical performance. The precision test conducted by repetitive analysis of 2,400 replicates with reference standards at various concentrations showed 99.9% agreement (2398/2400). The overall concordance rate between the HepB Typer-Entecavir kit and direct sequencing assays in 396 clinical samples was 99.5%. Conclusions The HepB Typer-Entecavir kit showed high reliability and precision, and comparable sensitivity and specificity for detecting mutant virus populations in reference and clinical samples in comparison with direct sequencing. Therefore, this assay would be clinically useful in the diagnosis of entecavir-resistance-associated mutations in chronic hepatitis B. PMID:24459645

  5. Serum lipoprotein changes in dogs with renal disease.

    PubMed

    Behling-Kelly, E

    2014-01-01

    People with renal disease develop a dyslipidemia that contributes to progression of renal injury and development of cardiovascular disease. Lipoproteins in dogs with renal disease have not been investigated. Dogs with chronic kidney disease (CKD) have dyslipidemia characterized by increased lower density lipoproteins and decreased high-density lipoproteins (HDLs). The degree of dyslipidemia is positively correlated with severity of disease, as reflected by serum creatinine concentration. Prospective study of client-owned dogs presented to the Cornell University Hospital for Animals: 29 dogs with confirmed CKD, 5 dogs with nephrotic syndrome (NS), and 12 healthy control dogs presented for routine vaccinations, dental cleaning, or owned by students. Lipoprotein electrophoresis was used to quantify relative proportions of the 3 main classes of lipoproteins in canine serum: low-density lipoproteins (LDL), very low-density lipoproteins (VLDL), and HDL. Serum cholesterol and creatinine concentrations; urinalysis and urine protein-to-creatinine ratio were measured by standard methods. Dyslipidemia was consistently found in dogs with CKD and NS and was characterized by a decrease in HDL and variable increases in LDL and VLDL. Dogs with NS had a proportionately greater increase in the VLDL fraction, as compared with dogs with CKD. Dyslipidemia similar to that documented in people with renal disease occurs in dogs with CKD, despite serum cholesterol concentrations often being within the reference interval. The contribution of altered lipoproteins to the pathogenesis of renal disease in dogs warrants additional study. Copyright © 2014 by the American College of Veterinary Internal Medicine.

  6. Concentrations of Polychlorinated Biphenyls and Organochlorine Pesticides in Umbilical Cord Blood Serum of Newborns in Kingston, Jamaica

    PubMed Central

    Rahbar, Mohammad H.; Samms-Vaughan, Maureen; Hessabi, Manouchehr; Dickerson, Aisha S.; Lee, MinJae; Bressler, Jan; Tomechko, Sara E.; Moreno, Emily K.; Loveland, Katherine A.; Desai, Charlene Coore; Shakespeare-Pellington, Sydonnie; Reece, Jody-Ann; Morgan, Renee; Geiger, Matthew J.; O’Keefe, Michael E.; Grove, Megan L.; Boerwinkle, Eric

    2016-01-01

    To date much of the biomonitoring related to exposure to polychlorinated biphenyls (PCBs) and organochlorine (OC) pesticides is from middle to high income countries, including the U.S., Canada and Europe, but such data are lacking for the majority of low to middle income countries. Using data from 64 pregnant mothers who were enrolled in 2011, we aimed to assess the concentrations of the aforementioned toxins in umbilical cord blood serum of 67 Jamaican newborns. For 97 of the 100 PCB congeners and 16 of the 17 OC pesticides, all (100%) concentrations were below their respective limits of detection (LOD). Mean (standard deviation (SD)) lipid-adjusted concentrations in cord blood serum for congeners PCB-153, PCB-180, PCB-206 and total PCB were 14.25 (3.21), 7.16 (1.71), 7.30 (1.74) and 28.15 (6.03) ng/g-lipid, respectively. The means (SD) for the 4,4′-dichlorodiphenyldichloroethylene (DDE)-hexane fraction and total-DDE were 61.61 (70.78) and 61.60 (70.76) ng/g-lipid, respectively. Compared to the U.S. and Canada, the concentrations of these toxins were lower in cord-blood serum of Jamaican newborns. We discuss that these differences could be partly due to differences in dietary patterns in these countries. Despite limitations in our dataset, our results provide information on the investigated toxins in cord blood serum that could serve as a reference for Jamaican newborns. PMID:27775677

  7. Factors Other than GFR Affecting Serum Cystatin C Levels

    PubMed Central

    Stevens, Lesley A; Schmid, Christopher H.; Greene, Tom; Li, Liang; Beck, Gerald J; Joffe, Marshall; Froissart, Marc; Kusek, John; Zhang, Yaping (Lucy); Coresh, Josef; Levey, Andrew S

    2015-01-01

    Cystatin C is gaining acceptance as an endogenous filtration marker. Factors other than glomerular filtration rate (GFR) that affect the serum level have not been carefully studied. In a cross-sectional analysis of a pooled dataset of participants from clinical trials and a clinical population with chronic kidney disease (N=3418), we related serum levels of cystatin C and creatinine to clinical and biochemical variables after adjustment for GFR using errors-in-variables models to account for GFR measurement error. GFR was measured as urinary clearance of 125I-iothalamate and 15Cr-EDTA. Cystatin C was assayed at a single laboratory and creatinine was standardized to reference methods. Mean (SD) creatinine and cystatin C were 2.1 (1.1) mg/dL and 1.8 (0.8) mg/L, respectively. After adjustment for GFR, cystatin C was 4.3% lower for every 20 years of age, 9.2% lower for female sex but only 1.9% lower in blacks. Diabetes was associated with 8.5% higher levels of cystatin C and 3.9% lower levels of creatinine. Higher C-reactive protein and white blood cell count and lower serum albumin were associated with higher levels of cystatin C and lower levels of creatinine. Adjustment for age, sex and race had a greater effect on association of factors with creatinine than cystatin C. In conclusion, cystatin C is affected by factors other than GFR. Clinicians should consider these factors when interpreting the serum levels or GFR estimates from cystatin C. PMID:19119287

  8. Analysis of human serum and whole blood for mineral content by ICP-MS and ICP-OES: development of a mineralomics method.

    PubMed

    Harrington, James M; Young, Daniel J; Essader, Amal S; Sumner, Susan J; Levine, Keith E

    2014-07-01

    Minerals are inorganic compounds that are essential to the support of a variety of biological functions. Understanding the range and variability of the content of these minerals in biological samples can provide insight into the relationships between mineral content and the health of individuals. In particular, abnormal mineral content may serve as an indicator of illness. The development of robust, reliable analytical methods for the determination of the mineral content of biological samples is essential to developing biological models for understanding the relationship between minerals and illnesses. This paper describes a method for the analysis of the mineral content of small volumes of serum and whole blood samples from healthy individuals. Interday and intraday precision for the mineral content of the blood (250 μL) and serum (250 μL) samples was measured for eight essential minerals--sodium (Na), calcium (Ca), magnesium (Mg), potassium (K), iron (Fe), zinc (Zn), copper (Cu), and selenium (Se)--by plasma spectrometric methods and ranged from 0.635 to 10.1% relative standard deviation (RSD) for serum and 0.348-5.98% for whole blood. A comparison of the determined ranges for ten serum samples and six whole blood samples provided good agreement with literature reference ranges. The results demonstrate that the digestion and analysis methods can be used to reliably measure the content of these minerals and potentially of other minerals.

  9. Acute phase proteins in healthy goats: establishment of reference intervals.

    PubMed

    Heller, Meera C; Johns, Jennifer L

    2015-03-01

    Acute inflammatory processes can trigger increased production of acute phase proteins (APPs) that can be useful biomarkers of inflammation. APPs are diverse and include proteins involved in coagulation, opsonization, iron regulation, and limitation of tissue injury. Haptoglobin, serum amyloid A, and alpha-1 acid glycoprotein have been proposed as useful APPs in goats. APPs can differ markedly by species, therefore species-specific reference intervals and studies are necessary. The objective of this study was to determine species-specific reference intervals for 4 APPs in goats. Haptoglobin, serum amyloid A, lipopolysaccharide binding protein, and alpha-1 acid glycoprotein were measured in in 54 clinically normal adult goats. APPs were measured using goat-specific commercial enzyme-linked immunosorbent assay kits. Results were analyzed by 1-way analysis of variance to compare sexes and breeding status. Reference Value Advisor was used to calculate reference limits according to the IFCC-CLSI guidelines. Only 1 APP was found to vary in healthy animals; serum haptoglobin was increased in lactating animals and decreased in pregnant does in their second trimester when compared with open, nonlactating does. No sex-based differences were seen for any of the APPs measured. We report normal reference intervals for 4 serum APPs that may be useful as disease markers. Haptoglobin should be interpreted with caution in animals with unknown pregnancy status. Further studies are needed to determine whether these APPs are useful biomarkers in goat disease states. © 2015 The Author(s).

  10. Combined dietary and exercise intervention for control of serum cholesterol in the workplace

    NASA Technical Reports Server (NTRS)

    Angotti, C. M.; Chan, W. T.; Sample, C. J.; Levine, M. S.

    2000-01-01

    PURPOSE: To elucidate a potential combined dietary and exercise intervention affect on cardiovascular risk reduction of the National Aeronautics and Space Administration Headquarters employees. DESIGN: A nonexperimental, longitudinal, clinical-chart review study (1987 to 1996) of an identified intervention group and a reference (not a control) group. SETTING: The study group worked in an office environment and participated in the annual medical examinations. SUBJECTS: An intervention group of 858 people with initially elevated serum cholesterol, and a reference group of 963 people randomly sampled from 10% of the study group. MEASURES: Serum cholesterol data were obtained for both groups, respectively, from pre- and postintervention and annual examinations. The reference group was adjusted by statistical exclusion of potential intervention participants. Regression equations (cholesterol vs. study years) for the unadjusted/adjusted reference groups were tested for statistical significance. INTERVENTION: An 8-week individualized, combined dietary and exercise program was instituted with annual follow-ups and was repeated where warranted. RESULTS: Only the unadjusted (but not the adjusted) reference group with initial mean total serum cholesterol levels above 200 mg/dL shows a significant 9-year decline trend and significant beta coefficient tests. An intervention effect is suggested. Mean high density lipoprotein cholesterol rose slightly in the intervention group but was maintained in the reference group. CONCLUSION: With potential design limitations, the NASA intervention program focusing on a high risk group may be associated to some degree, if not fully, with an overall cardiovascular risk profile improvement.

  11. Specific Immunoglobulin (Ig) G Reference Intervals for Common Food, Insect, and Mold Allergens.

    PubMed

    Martins, Thomas B; Bandhauer, Michael E; Wilcock, Diane M; Hill, Harry R; Slev, Patricia R

    2016-12-01

    The clinical utility of serum IgG measurement in the diagnosis of allergy and food-induced hypersensitivity has been largely discredited. Recent studies, however, have shown that specific IgG can inhibit IgE mediated allergies, and may play a role in allergen specific desensitization. Accurate reference intervals for IgG specific allergens have not been widely established and are needed for better interpretation of serum antibody concentrations. In this study we established 64 IgG reference intervals for 48 common food allergens, 5 venoms, and 11 molds. Specific IgG concentrations were determined employing an automated fluorescent enzyme immunoassay on serum samples from 130 normal adults (65 males and 65 females), age range 18-69 y, mean 37.3 y. The lower reference interval limit for all allergens tested (n=64) was <2 mcg/mL. The median upper reference interval value for all 64 allergens was 12.9 mcg/mL, with Tuna (f40) having the lowest upper interval limit at 3.8 mcg/mL, and the mold Setomelanomma rostrate (m8) demonstrating the highest upper interval limit at 131 mcg/L. The considerable variation observed among the upper reference interval limits emphasizes the need for the establishment of allergen specific ranges for IgG. These newly established ranges should be a useful aid for clinicians in the interpretation of laboratory serum IgG results. © 2016 by the Association of Clinical Scientists, Inc.

  12. Age-specific reference values for serum FSH and estradiol levels throughout the reproductive period.

    PubMed

    Grisendi, Valentina; Spada, Elena; Argento, Cindy; Plebani, Maddalena; Milani, Silvano; Seracchioli, Renato; Volpe, Annibale; La Marca, Antonio

    2014-06-01

    High serum day 3 FSH levels are associated with poor ovarian reserve and reduced fertility, but the interpretation of FSH values according to age is still not univocal. The purpose of this study was to determine age-dependent reference values in women with regular menstrual cycles and FSH as a guide for specialists. The study was performed at the Department of Mother-Infant of a University-based tertiary care centre. One-hundred ninety-two healthy normal menstruating women were recruited for the study. All patients attended the department on menstrual cycle day 3 for a blood sample for FSH and estradiol determination. A linear relationship between FSH or estradiol serum levels and age was observed. The FSH level increased by 0.11 IU for every year of age (1 IU for every 9 years of age). The values of FSH and estradiol corresponding to the 5th, 25th, 50th, 75th, 95th centiles for any specific age have been calculated. Serum FSH levels need to be interpreted according to age-dependent reference values. Serum FSH levels on 95th centile for any age may represent a warning sign for reduced ovarian reserve.

  13. Serum antioxidant capacity and peroxide level of seven healthy subjects after consumption of different foods.

    PubMed

    Laus, Maura N; Soccio, Mario; Alfarano, Michela; Pasqualone, Antonella; Lenucci, Marcello S; Di Miceli, Giuseppe; Pastore, Donato

    2016-12-01

    This article reports experimental data related to the research article entitled "Different effectiveness of two pastas supplemented with either lipophilic or hydrophilic/phenolic antioxidants in affecting serum as evaluated by the novel Antioxidant/Oxidant Balance approach" (M.N. Laus, M. Soccio, M. Alfarano, A. Pasqualone, M.S. Lenucci, G. Di Miceli, D. Pastore, 2016) [1]. Antioxidant status of blood serum of seven healthy subjects was evaluated during four hours after consumption of two functional pastas, supplemented with either bran oleoresin or bran water extract obtained from durum wheat. For comparison, the effect of a non-supplemented reference pasta was also evaluated, as well as the effects of glucose, of the wheat grain dietary supplement Lisosan G, and of the reference pasta consumed together with Lisosan G. Serum antioxidant status was evaluated by measuring both the serum antioxidant capacity, using LOX-FL, ORAC and TEAC methods, and the serum oxidant status, assessed as peroxide level.

  14. Goitrous hypothyroidism associated with treatment with trimethoprim-sulfamethoxazole in a young dog.

    PubMed

    Seelig, Davis M; Whittemore, Jacqueline C; Lappin, Michael R; Myers, Alan M; Avery, Paul R

    2008-04-15

    A 16-week-old female Boxer that had been treated for 5 weeks with trimethoprim-sulfamethoxazole and chloramphenicol because of aspiration pneumonia was evaluated for bilaterally symmetric masses in the subcutaneous tissues of the ventral neck, in the region of the larynx. Fine-needle aspirates were obtained from the neck masses; cytologic examination revealed well-differentiated thyroid epithelial tissue. A blood sample was collected for serum biochemical and thyroid function analyses. Mild hyperphosphatemia, severe hypercholesterolemia, mild hyperkalemia, and a mild increase in creatine kinase activity were identified. Serum concentration of total thyroxine was less than the lower reference limit, and that of thyroid-stimulating hormone was greater than the upper reference limit. Findings were consistent with a diagnosis of clinical hypothyroidism in a skeletally immature dog. Treatment with trimethoprim-sulfamethoxazole was discontinued. The dog was reevaluated 3 weeks later, at which time the neck masses were markedly decreased in size. Serum concentrations of cholesterol and potassium were lower; serum concentrations of total thyroxine and thyroid-stimulating hormone were near or within respective reference ranges. Age-appropriate increases in serum phosphorus concentration and serum alkaline phosphatase activity were also detected. To the authors' knowledge, this is the first report of antimicrobial-induced goiter in a dog. Cytologic examination of fine-needle aspirates and interpretation of data from serum biochemical and thyroid function analyses were needed to obtain a definitive diagnosis. Practitioners should include goiter among the differential diagnoses for ventral neck swellings in young dogs receiving potentiated sulfonamide antimicrobials.

  15. Serum Biochemical Phenotypes in the Domestic Dog

    PubMed Central

    Chang, Yu-Mei; Hadox, Erin; Szladovits, Balazs; Garden, Oliver A.

    2016-01-01

    The serum or plasma biochemical profile is essential in the diagnosis and monitoring of systemic disease in veterinary medicine, but current reference intervals typically take no account of breed-specific differences. Breed-specific hematological phenotypes have been documented in the domestic dog, but little has been published on serum biochemical phenotypes in this species. Serum biochemical profiles of dogs in which all measurements fell within the existing reference intervals were retrieved from a large veterinary database. Serum biochemical profiles from 3045 dogs were retrieved, of which 1495 had an accompanying normal glucose concentration. Sixty pure breeds plus a mixed breed control group were represented by at least 10 individuals. All analytes, except for sodium, chloride and glucose, showed variation with age. Total protein, globulin, potassium, chloride, creatinine, cholesterol, total bilirubin, ALT, CK, amylase, and lipase varied between sexes. Neutering status significantly impacted all analytes except albumin, sodium, calcium, urea, and glucose. Principal component analysis of serum biochemical data revealed 36 pure breeds with distinctive phenotypes. Furthermore, comparative analysis identified 23 breeds with significant differences from the mixed breed group in all biochemical analytes except urea and glucose. Eighteen breeds were identified by both principal component and comparative analysis. Tentative reference intervals were generated for breeds with a distinctive phenotype identified by comparative analysis and represented by at least 120 individuals. This is the first large-scale analysis of breed-specific serum biochemical phenotypes in the domestic dog and highlights potential genetic components of biochemical traits in this species. PMID:26919479

  16. Analysis of serum angiotensin-converting enzyme.

    PubMed

    Muller, B R

    2002-09-01

    Serum angiotensin-converting enzyme (SACE) levels are influenced by genetic polymorphism. Interpretation of serum levels with the appropriate genotypic reference range improves the diagnostic sensitivity of the assay for sarcoidosis. SACE assays are performed by a large number of routine clinical laboratories. However, there is no external quality assessment (EQA) for SACE other than an informal regional scheme. This showed analytical performance of SACE assays to be poor, with a diversity of reference ranges, leading to widely disparate clinical classification of EQA samples. Genetic polymorphism combined with poor analytical performance suggest that perhaps SACE assays should revert to being the province of specialized laboratories.

  17. Accuracy of prediction equations for serum osmolarity in frail older people with and without diabetes1234

    PubMed Central

    Siervo, Mario; Bunn, Diane; Prado, Carla M; Hooper, Lee

    2014-01-01

    Background: Serum osmolality is an accurate indicator of hydration status in older adults. Glucose, urea, and electrolyte concentrations are used to calculate serum osmolarity, which is an indirect estimate of serum osmolality, but which serum osmolarity equations best predict serum osmolality in the elderly is unclear. Objective: We assessed the agreement of measured serum osmolality with calculated serum osmolarity equations in older people. Design: Serum osmolality was measured by using freezing point depression in a cross-sectional study. Plasma glucose, urea, and electrolytes were analyzed and entered into 38 serum osmolarity-prediction equations. The Bland-Altman method was used to evaluate the agreement and differential bias between measured osmolality and calculated osmolarity. The sensitivity and specificity of the most-promising equations were examined against serum osmolality (reference standard). Results: A total of 186 people living in UK residential care took part in the Dehydration Recognition In our Elders study (66% women; mean ± SD age: 85.8 ± 7.9 y; with a range of cognitive and physical impairments) and were included in analyses. Forty-six percent of participants had impending or current dehydration (serum osmolality ≥295 mmol/kg). Participants with diabetes (n = 33; 18%) had higher glucose (P < 0.001) and serum osmolality (P < 0.01). Of 38 predictive equations used to calculate osmolarity, 4 equations showed reasonable agreement with measured osmolality. One [calculated osmolarity = 1.86 × (Na+ + K+) + 1.15 × glucose + urea +14; all in mmol/L] was characterized by narrower limits of agreement and the capacity to predict serum osmolality within 2% in >80% of participants, regardless of diabetes or hydration status. The equation's sensitivity (79%) and specificity (89%) for impending dehydration (≥295 mmol/kg) and current dehydration (>300 mmol/kg) (69% and 93%, respectively) were reasonable. Conclusions: The assessment of a panel of equations for the prediction of serum osmolarity led to identification of one formula with a greater diagnostic performance. This equation may be used to predict hydration status in frail older people (as a first-stage screening) or to estimate hydration status in population studies. This trial was registered at the Research Register for Social Care (http://www.researchregister.org.uk) as 122273. PMID:25030781

  18. Is it possible to diagnose canine hypothyroidism?

    PubMed

    Panciera, D L

    1999-04-01

    A definitive diagnosis of hypothyroidism can be difficult because of the many clinical abnormalities associated with thyroid hormone deficiency, and the lack of readily available diagnostic tests with high sensitivity and specificity. Thyroid function tests should be performed only in dogs with clinical findings consistent with hypothyroidism. Measurement of serum total thyroxine (T4) concentration is a useful initial screening test since most hypothyroid dogs have values below the reference range. Serum free T4 concentration measured by equilibrium dialysis is a more sensitive and specific test of thyroid function than total T4 and is particularly useful in dogs with non-thyroidal illness or atypical clinical signs. Measurement of serum endogenous thyroid-stimulating hormone concentration is also helpful, but many hypothyroid dogs have normal results. The gold standard for diagnosis of hypothyroidism remains the thyroid-stimulating hormone response test. It should be used to confirm hypothyroidism when other tests do not agree with the clinical impression or if atypical signs or non-thyroidal illness exist or there has been administration of drugs known to alter thyroid function tests. Ultimately, a positive response to treatment is expected in hypothyroid dogs treated appropriately with levothyroxine.

  19. Evaluation of a recombinant LigB protein of Leptospira interrogans serovar Canicola in an enzyme-linked immunosorbent assay for the serodiagnosis of bovine leptospirosis.

    PubMed

    Sankar, Surya; Harshan, Hiron M; Somarajan, S R; Srivastava, S K

    2010-06-01

    A recombinant leptospiral lipoprotein, LigB, was evaluated for use in the diagnosis of bovine leptospirosis by enzyme-linked immunosorbent assay (rLigB IgG ELISA). The standard reference test (Microscopic agglutination test, MAT) of 200 serum samples from cattle suspected of leptospirosis showed that 95 (47.5%) samples had positive agglutination titres, which ranged from 100 to 1600. In rLigB IgG ELISA, 49% of the samples were positive. Sensitivity of IgG ELISA for 95 bovine sera, which had MAT titres of greater than or equal to 100, were 100%. ELISA showed a specificity of 97.1% with 105 bovine sera, which were negative at a 1:50 dilution in MAT for Leptospira interrogans serovars. The results of ELISA and MAT correspond very good. When analytical specificity of IgG ELISA was evaluated using bovine serum samples from animals showing the serum antibodies to other pathogens, no cross-reaction was observed. Thus the recombinant LigB IgG ELISA can be used instead of the MAT as an aid to the diagnosis of bovine leptospirosis. Copyright 2009. Published by Elsevier India Pvt Ltd.

  20. Global Panel of HIV-1 Env Reference Strains for Standardized Assessments of Vaccine-Elicited Neutralizing Antibodies

    PubMed Central

    deCamp, Allan; Hraber, Peter; Bailer, Robert T.; Seaman, Michael S.; Ochsenbauer, Christina; Kappes, John; Gottardo, Raphael; Edlefsen, Paul; Self, Steve; Tang, Haili; Greene, Kelli; Gao, Hongmei; Daniell, Xiaoju; Sarzotti-Kelsoe, Marcella; Gorny, Miroslaw K.; Zolla-Pazner, Susan; LaBranche, Celia C.; Mascola, John R.; Korber, Bette T.

    2014-01-01

    ABSTRACT Standardized assessments of HIV-1 vaccine-elicited neutralizing antibody responses are complicated by the genetic and antigenic variability of the viral envelope glycoproteins (Envs). To address these issues, suitable reference strains are needed that are representative of the global epidemic. Several panels have been recommended previously, but no clear answers have been available on how many and which strains are best suited for this purpose. We used a statistical model selection method to identify a global panel of reference Env clones from among 219 Env-pseudotyped viruses assayed in TZM-bl cells with sera from 205 HIV-1-infected individuals. The Envs and sera were sampled globally from diverse geographic locations and represented all major genetic subtypes and circulating recombinant forms of the virus. Assays with a panel size of only nine viruses adequately represented the spectrum of HIV-1 serum neutralizing activity seen with the larger panel of 219 viruses. An optimal panel of nine viruses was selected and augmented with three additional viruses for greater genetic and antigenic coverage. The spectrum of HIV-1 serum neutralizing activity seen with the final 12-virus panel closely approximated the activity seen with subtype-matched viruses. Moreover, the final panel was highly sensitive for detection of many of the known broadly neutralizing antibodies. For broader assay applications, all 12 Env clones were converted to infectious molecular clones using a proviral backbone carrying a Renilla luciferase reporter gene (Env.IMC.LucR viruses). This global panel should facilitate highly standardized assessments of vaccine-elicited neutralizing antibodies across multiple HIV-1 vaccine platforms in different parts of the world. IMPORTANCE An effective HIV-1 vaccine will need to overcome the extraordinary genetic variability of the virus, where most variation occurs in the viral envelope glycoproteins that are the sole targets for neutralizing antibodies. Efforts to elicit broadly cross-reactive neutralizing antibodies that will protect against infection by most circulating strains of the virus are guided in part by in vitro assays that determine the ability of vaccine-elicited antibodies to neutralize genetically diverse HIV-1 variants. Until now, little information was available on how many and which strains of the virus are best suited for this purpose. We applied robust statistical methods to evaluate a large neutralization data set and identified a small panel of viruses that are a good representation of the global epidemic. The neutralization properties of this new panel of reference strains should facilitate the development of an effective HIV-1 vaccine. PMID:24352443

  1. Global panel of HIV-1 Env reference strains for standardized assessments of vaccine-elicited neutralizing antibodies.

    PubMed

    deCamp, Allan; Hraber, Peter; Bailer, Robert T; Seaman, Michael S; Ochsenbauer, Christina; Kappes, John; Gottardo, Raphael; Edlefsen, Paul; Self, Steve; Tang, Haili; Greene, Kelli; Gao, Hongmei; Daniell, Xiaoju; Sarzotti-Kelsoe, Marcella; Gorny, Miroslaw K; Zolla-Pazner, Susan; LaBranche, Celia C; Mascola, John R; Korber, Bette T; Montefiori, David C

    2014-03-01

    Standardized assessments of HIV-1 vaccine-elicited neutralizing antibody responses are complicated by the genetic and antigenic variability of the viral envelope glycoproteins (Envs). To address these issues, suitable reference strains are needed that are representative of the global epidemic. Several panels have been recommended previously, but no clear answers have been available on how many and which strains are best suited for this purpose. We used a statistical model selection method to identify a global panel of reference Env clones from among 219 Env-pseudotyped viruses assayed in TZM-bl cells with sera from 205 HIV-1-infected individuals. The Envs and sera were sampled globally from diverse geographic locations and represented all major genetic subtypes and circulating recombinant forms of the virus. Assays with a panel size of only nine viruses adequately represented the spectrum of HIV-1 serum neutralizing activity seen with the larger panel of 219 viruses. An optimal panel of nine viruses was selected and augmented with three additional viruses for greater genetic and antigenic coverage. The spectrum of HIV-1 serum neutralizing activity seen with the final 12-virus panel closely approximated the activity seen with subtype-matched viruses. Moreover, the final panel was highly sensitive for detection of many of the known broadly neutralizing antibodies. For broader assay applications, all 12 Env clones were converted to infectious molecular clones using a proviral backbone carrying a Renilla luciferase reporter gene (Env.IMC.LucR viruses). This global panel should facilitate highly standardized assessments of vaccine-elicited neutralizing antibodies across multiple HIV-1 vaccine platforms in different parts of the world. An effective HIV-1 vaccine will need to overcome the extraordinary genetic variability of the virus, where most variation occurs in the viral envelope glycoproteins that are the sole targets for neutralizing antibodies. Efforts to elicit broadly cross-reactive neutralizing antibodies that will protect against infection by most circulating strains of the virus are guided in part by in vitro assays that determine the ability of vaccine-elicited antibodies to neutralize genetically diverse HIV-1 variants. Until now, little information was available on how many and which strains of the virus are best suited for this purpose. We applied robust statistical methods to evaluate a large neutralization data set and identified a small panel of viruses that are a good representation of the global epidemic. The neutralization properties of this new panel of reference strains should facilitate the development of an effective HIV-1 vaccine.

  2. The flexibility of a generic LC-MS/MS method for the quantitative analysis of therapeutic proteins based on human immunoglobulin G and related constructs in animal studies.

    PubMed

    Lanshoeft, Christian; Wolf, Thierry; Walles, Markus; Barteau, Samuel; Picard, Franck; Kretz, Olivier; Cianférani, Sarah; Heudi, Olivier

    2016-11-30

    An increasing demand of new analytical methods is associated with the growing number of biotherapeutic programs being prosecuted in the pharmaceutical industry. Whilst immunoassay has been the standard method for decades, a great interest in assays based on liquid chromatography tandem mass spectrometry (LC-MS/MS) is evolving. In this present work, the development of a generic method for the quantitative analysis of therapeutic proteins based on human immunoglobulin G (hIgG) in rat serum is reported. The method is based on four generic peptides GPSVFPLAPSSK (GPS), TTPPVLDSDGSFFLYSK (TTP), VVSVLTVLHQDWLNGK (VVS) and FNWYVDGVEVHNAK (FNW) originating from different parts of the fraction crystallizable (Fc) region of a reference hIgG1 (hIgG1A). A tryptic pellet digestion of rat serum spiked with hIgG1A and a stable isotope labeled protein (hIgG1B) used as internal standard (ISTD) was applied prior LC-MS/MS analysis. The upper limit of quantification was at 1000μg/mL. The lower limit of quantitation was for GPS, TTP and VVS at 1.00μg/mL whereas for FNW at 5.00μg/mL. Accuracy and precision data met acceptance over three days. The presented method was further successfully applied to the quantitative analysis of other hIgG1s (hIgG1C and hIgG1D) and hIgG4-based therapeutic proteins on spiked quality control (QC) samples in monkey and rat serum using calibration standards (Cs) prepared with hIgG1A in rat serum. In order to extend the applicability of our generic approach, a bispecific-bivalent hIgG1 (bb-hIgG1) and two lysine conjugated antibody-drug conjugates (ADC1 and ADC2) were incorporated as well. The observed values on spiked QC samples in monkey serum were satisfactory with GPS for the determination of bb-hIgG1 whereas the FNW and TTP peptides were suitable for the ADCs. Moreover, comparable mean concentration-time profiles were obtained from monkeys previously dosed intravenously with ADC2 measured against Cs samples prepared either with hIgG1A in rat serum (presented approach) or with the actual ADC2 in monkey serum (conventional approach). The results of this study highlight the great flexibility of our newly developed generic approach and that the choice of the surrogate peptide still remains critical when dealing with different matrix types or modalities. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Estimating GFR Among Participants in the Chronic Renal Insufficiency Cohort (CRIC) Study

    PubMed Central

    Anderson, Amanda Hyre; Yang, Wei; Hsu, Chi-yuan; Joffe, Marshall M.; Leonard, Mary B.; Xie, Dawei; Chen, Jing; Greene, Tom; Jaar, Bernard G.; Kao, Patricia; Kusek, John W.; Landis, J. Richard; Lash, James P.; Townsend, Raymond R.; Weir, Matthew R.; Feldman, Harold I.

    2012-01-01

    Background Glomerular filtration rate (GFR) is considered the best measure of kidney function, but repeated assessment is not feasible in most research studies. Study Design Cross-sectional study of 1,433 participants from the Chronic Renal Insufficiency Cohort (CRIC) Study (i.e., the GFR subcohort) to derive an internal GFR estimating equation using a split sample approach. Setting & Participants Adults from 7 US metropolitan areas with mild to moderate chronic kidney disease; 48% had diabetes and 37% were black. Index Test CRIC GFR estimating equation Reference Test or Outcome Urinary 125I-iothalamate clearance testing (measured GFR) Other Measurements Laboratory measures including serum creatinine and cystatin C, and anthropometrics Results In the validation dataset, the model that included serum creatinine, serum cystatin C, age, gender, and race was the most parsimonious and similarly predictive of mGFR compared to a model additionally including bioelectrical impedance analysis phase angle, CRIC clinical center, and 24-hour urinary creatinine excretion. Specifically, the root mean square errors for the separate model were 0.207 vs. 0.202, respectively. The performance of the CRIC GFR estimating equation was most accurate among the subgroups of younger participants, men, non-blacks, non-Hispanics, those without diabetes, those with body mass index <30 kg/m2, those with higher 24-hour urine creatinine excretion, those with lower levels of high-sensitivity C-reactive protein, and those with higher mGFR. Limitations Urinary clearance of 125I-iothalamate is an imperfect measure of true GFR; cystatin C is not standardized to certified reference material; lack of external validation; small sample sizes limit analyses of subgroup-specific predictors. Conclusions The CRIC GFR estimating equation predicts measured GFR accurately in the CRIC cohort using serum creatinine and cystatin C, age, gender, and race. Its performance was best among younger and healthier participants. PMID:22658574

  4. Evaluation of the Aspergillus Western Blot IgG Kit for Diagnosis of Chronic Aspergillosis

    PubMed Central

    Oliva, A.; Flori, P.; Hennequin, C.; Dubus, J.-C.; Reynaud-Gaubert, M.; Charpin, D.; Vergnon, J. M.; Gay, P.; Colly, A.; Piarroux, R.; Pelloux, H.

    2014-01-01

    Immunoprecipitin detection (IPD) is the current reference confirmatory technique for anti-Aspergillus antibody detection; however, the lack of standardization is a critical drawback of this assay. In this study, we evaluated the performance of the Aspergillus Western blot (Asp-WB) IgG kit (LDBio Diagnostics, Lyon, France), a recently commercialized immunoblot assay for the diagnosis of various clinical presentations of chronic aspergillosis. Three hundred eight serum samples from 158 patients with aspergillosis sensu lato (s.l.) were analyzed. More specifically, 267 serum samples were derived from patients with Aspergillus disease, including 89 cases of chronic pulmonary aspergillosis, 10 of aspergilloma, and 32 of allergic bronchopulmonary aspergillosis, while 41 samples were from patients with Aspergillus colonization, including 15 cystic fibrosis (CF) and 12 non-CF patients. For blood donor controls, the Asp-WB specificity was 94%, while the kit displayed a sensitivity for the aspergillosis s.l. diagnosis of 88.6%, with a diagnostic odds ratio (DOR) of 119 (95% confidence interval [CI], 57 to 251). The DOR values were 185.22 (95% CI,78.79 to 435.45) and 43.74 (95% CI, 15.65 to 122.20) for the diagnosis of Aspergillus disease and Aspergillus colonization, respectively. Among the patients, the sensitivities of the Asp-WB in the diagnosis of Aspergillus colonization were 100% and 41.7% in CF and non-CF patients, respectively. The Asp-WB yielded fewer false-negative results than did IPD. In conclusion, the Asp-WB kit performed well for the diagnosis of various clinical presentations of aspergillosis in nonimmunocompromised patients, with an enhanced standardization and a higher sensitivity than with IPD, which is the current reference method. PMID:25392351

  5. Evaluation of the Aspergillus Western blot IgG kit for diagnosis of chronic aspergillosis.

    PubMed

    Oliva, A; Flori, P; Hennequin, C; Dubus, J-C; Reynaud-Gaubert, M; Charpin, D; Vergnon, J M; Gay, P; Colly, A; Piarroux, R; Pelloux, H; Ranque, S

    2015-01-01

    Immunoprecipitin detection (IPD) is the current reference confirmatory technique for anti-Aspergillus antibody detection; however, the lack of standardization is a critical drawback of this assay. In this study, we evaluated the performance of the Aspergillus Western blot (Asp-WB) IgG kit (LDBio Diagnostics, Lyon, France), a recently commercialized immunoblot assay for the diagnosis of various clinical presentations of chronic aspergillosis. Three hundred eight serum samples from 158 patients with aspergillosis sensu lato (s.l.) were analyzed. More specifically, 267 serum samples were derived from patients with Aspergillus disease, including 89 cases of chronic pulmonary aspergillosis, 10 of aspergilloma, and 32 of allergic bronchopulmonary aspergillosis, while 41 samples were from patients with Aspergillus colonization, including 15 cystic fibrosis (CF) and 12 non-CF patients. For blood donor controls, the Asp-WB specificity was 94%, while the kit displayed a sensitivity for the aspergillosis s.l. diagnosis of 88.6%, with a diagnostic odds ratio (DOR) of 119 (95% confidence interval [CI], 57 to 251). The DOR values were 185.22 (95% CI,78.79 to 435.45) and 43.74 (95% CI, 15.65 to 122.20) for the diagnosis of Aspergillus disease and Aspergillus colonization, respectively. Among the patients, the sensitivities of the Asp-WB in the diagnosis of Aspergillus colonization were 100% and 41.7% in CF and non-CF patients, respectively. The Asp-WB yielded fewer false-negative results than did IPD. In conclusion, the Asp-WB kit performed well for the diagnosis of various clinical presentations of aspergillosis in nonimmunocompromised patients, with an enhanced standardization and a higher sensitivity than with IPD, which is the current reference method. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  6. On the certification of cadmium at trace and ultratrace levels in standard reference materials using ID ICP-MS.

    PubMed

    Murphy, K E; Long, S E; Vocke, R D

    2007-04-01

    Analytical methods used for the isotope dilution inductively coupled plasma mass spectrometric (ID-ICP-MS) measurement of Cd at microg kg(-1) and sub-microg kg(-1) levels are described and applied to the certification of new dietary supplement, blood, and serum Standard Reference Materials (SRMs). The materials are: SRM 3240 Ephedra sinica Stapf Aerial Parts, SRM 3241 Ephedra sinica Stapf Native Extract, SRM 3243 Ephedra-Containing Solid Oral Dosage Form, SRM 3244 Ephedra-Containing Protein Powder, SRM 966 Toxic Metals in Bovine Blood, Level 1 (L1) and Level 2 (L2), and SRM 1598a Animal Serum. The concentration of Cd in the materials ranges from 120 microg kg(-1) down to 0.03 microg kg(-1). At these levels, the factors that most influence the accuracy of the ICP-MS data are the procedure blank and spectral and nonspectral interferences. Nonspectral interference, caused by the high concentration of dissolved solids in the matrices investigated, resulted in signal suppression. Matrix separation was used to enhance signal intensity and to reduce spectral interference for the accurate determination of Cd in SRM 1598a and SRM 3244. Chromatographic separation procedures using Chelex for SRM 1598a and anion exchange for SRM 3244 were optimized to achieve the desired separation characteristics without substantially increasing the procedure blank. Sensitivity for the determination of Cd in serum was additionally enhanced through the use of desolvation nebulization. We determined that separations were not required for the accurate ICP-MS determination of Cd in SRM 3240, SRM 3241, SRM 3243, and SRM 966 L2 under optimized analysis conditions. These samples were diluted to a minimum volume and introduced to the ICP-MS via low flow (40-100 microL/min) microconcentric nebulizers. SRM 966 L1 was also analyzed directly, but results were highly variable. The ID-ICP-MS sample preparation and ratio measurement protocols described here resulted in total expanded uncertainties of less than 1% for the determination of 90.85 microg kg(-1) Cd in SRM 3240, and less than 10% total expanded uncertainty for the determination of 0.0468 microg kg(-1) Cd in SRM 1598a.

  7. How the reference values for serum parathyroid hormone concentration are (or should be) established?

    PubMed

    Souberbielle, J-C; Brazier, F; Piketty, M-L; Cormier, C; Minisola, S; Cavalier, E

    2017-03-01

    Well-validated reference values are necessary for a correct interpretation of a serum PTH concentration. Establishing PTH reference values needs recruiting a large reference population. Exclusion criteria for this population can be defined as any situation possibly inducing an increase or a decrease in PTH concentration. As recommended in the recent guidelines on the diagnosis and management of asymptomatic primary hyperparathyroidism, PTH reference values should be established in vitamin D-replete subjects with a normal renal function with possible stratification according to various factors such as age, gender, menopausal status, body mass index, and race. A consensus about analytical/pre-analytical aspects of PTH measurement is also needed with special emphasis on the nature of the sample (plasma or serum), the time and the fasting/non-fasting status of the blood sample. Our opinion is that blood sample for PTH measurement should be obtained in the morning after an overnight fast. Furthermore, despite longer stability of the PTH molecule in EDTA plasma, we prefer serum as it allows to measure calcium, a prerequisite for a correct interpretation of a PTH concentration, on the same sample. Once a consensus is reached, we believe an important international multicentre work should be performed to recruit a very extensive reference population of apparently healthy vitamin D-replete subjects with a normal renal function in order to establish the PTH normative data. Due to the huge inter-method variability in PTH measurement, a sufficient quantity of blood sample should be obtained to allow measurement with as many PTH kits as possible.

  8. Diabetes in Relation to Serum Levels of Polychlorinated Biphenyls and Chlorinated Pesticides in Adult Native Americans

    PubMed Central

    Codru, Neculai; Schymura, Maria J.; Negoita, Serban; Rej, Robert; Carpenter, David O.

    2007-01-01

    Background Recent research suggests that diabetes, a condition whose incidence is increasing, is associated with exposure to polychlorinated biphenyls (PCBs) and chlorinated pesticides. Objectives We investigated the potential association between diabetes and serum levels of PCBs, dichlorodiphenyldichloroethylene (DDE), hexachlorobenzene (HCB), and mirex in a cross-sectional study of an adult Native-American (Mohawk) population. Methods Through a standardized questionnaire we collected demographic, medical, and lifestyle information from 352 adults, ≥30 years of age. We collected fasting serum samples that were analyzed for 101 PCB congeners, DDE, HCB, and mirex along with fasting glucose, triglycerides, and cholesterol. Participants who had fasting-glucose values > 125 mg/dL and/or who were taking antidiabetic medication were defined as persons with diabetes. We conducted logistic regression to assess the potential association between organochlorine serum levels and diabetes, while controlling for the potential confounding variables of age, body mass index (BMI), smoking, sex, and serum lipid levels. Organochlorine serum levels were categorized in tertiles, and the lowest tertile was used as the reference category. Results The prevalence of diabetes was 20.2%. The odds ratio (OR) of having diabetes for participants in the highest tertile of total PCB concentration compared with the lowest tertile was 3.9 (95% confidence interval, 1.5–10.6). The corresponding ORs for DDE and HCB were even higher. Elevated serum mirex was not associated with diabetes. After adjustment for other analytes, the OR for HCB remained significant, whereas ORs for PCBs and DDE remained elevated but not statistically significant. In contrast, after adjustment for other analytes, the OR for mirex became statistically significant and indicated an inverse association. Conclusions In this study of adult Native Americans, elevated serum PCBs, DDE, and HCB were positively associated with diabetes after controlling for potential confounders, whereas a negative association was observed for mirex. PMID:17938733

  9. [Serum S100β protein reference values in a paediatric population].

    PubMed

    Arroyo Hernández, M; Rodríguez Suárez, J; Álvarez Menéndez, F

    2016-05-01

    S100β protein has been proposed as a potential biomarker for both chronic and acute neurological disorders. Reference values of this protein are well defined in adults but not in children, in whom serum levels appear to vary with age. Reference values for serum S100β in children from 0 to 14 years are presented. A prospective study was conducted on 257 healthy children, who were divided into three age groups (under 12 months, 12 to 24 months and over 24 months). The study included179 boys and 78 girls, with a mean age of 5.5 (3.75) years. The mean serum concentration of protein S100β was 0.156 (0.140-0.172) μg/l. In children under 12 months, serum S100β concentration was 0.350 (0.280-0.421) μg/l; 0.165 (0.139-0.190) μg/l in the group between 12 and 24 months and 0.121 (0.109-0.133) μg/l in children older than 24 months. An inverse relationship was observed between age and serum S100β, which declines as age increases. No differences were observed between sexes. The concentration of S100β remains stable after two years of age, being possible to establish a baseline of S100β for over two years. During the first two years of life, S100β serum concentration is higher, the lower the age of the child. No differences in serum S100β levels between sexes are observed. Copyright © 2015 Asociación Española de Pediatría. Published by Elsevier España, S.L.U. All rights reserved.

  10. Imperfect Gold Standards for Kidney Injury Biomarker Evaluation

    PubMed Central

    Betensky, Rebecca A.; Emerson, Sarah C.; Bonventre, Joseph V.

    2012-01-01

    Clinicians have used serum creatinine in diagnostic testing for acute kidney injury for decades, despite its imperfect sensitivity and specificity. Novel tubular injury biomarkers may revolutionize the diagnosis of acute kidney injury; however, even if a novel tubular injury biomarker is 100% sensitive and 100% specific, it may appear inaccurate when using serum creatinine as the gold standard. Acute kidney injury, as defined by serum creatinine, may not reflect tubular injury, and the absence of changes in serum creatinine does not assure the absence of tubular injury. In general, the apparent diagnostic performance of a biomarker depends not only on its ability to detect injury, but also on disease prevalence and the sensitivity and specificity of the imperfect gold standard. Assuming that, at a certain cutoff value, serum creatinine is 80% sensitive and 90% specific and disease prevalence is 10%, a new perfect biomarker with a true 100% sensitivity may seem to have only 47% sensitivity compared with serum creatinine as the gold standard. Minimizing misclassification by using more strict criteria to diagnose acute kidney injury will reduce the error when evaluating the performance of a biomarker under investigation. Apparent diagnostic errors using a new biomarker may be a reflection of errors in the imperfect gold standard itself, rather than poor performance of the biomarker. The results of this study suggest that small changes in serum creatinine alone should not be used to define acute kidney injury in biomarker or interventional studies. PMID:22021710

  11. An evaluation of the use of serum 7-alpha-hydroxycholestenone as a diagnostic test of bile acid malabsorption causing watery diarrhea

    PubMed Central

    Brydon, W Gordon; Culbert, Pearl; Kingstone, Kathleen; Jarvie, Ann; Iacucci, Marietta; Tenhage, Merel; Ghosh, Subrata

    2011-01-01

    BACKGROUND: Bile acid malabsorption (BAM) is a recognized cause of watery diarrhea, often diagnosed empirically based on clinical response to cholestyramine. The radionuclide selenium-labelled homocholic acid-taurine whole body retention test is expensive, labour intensive and of limited availability. OBJECTIVE: To report on the clinical performance of serum 7-alpha-hydroxy-4-cholesten-3-one (7HCO) as a test of BAM in adult patients with unexplained diarrhea. METHODS: Patients with unexplained diarrhea were investigated over a three-year period. Final diagnosis was determined based on medical history and investigations, serum levels of 7HCO and response to cholestyramine. ROC analysis was used to determine the ideal upper reference range cut-off value to optimize sensitivity/specificity for BAM. Time of blood specimen collection was recorded to investigate possible variation in results throughout the working day. RESULTS: ROC analysis yielded a sensitivity/specificity of 90%/77% for type 1 BAM (ileal disease/resection) and 97%/74% for type 2 BAM (idiopathic) using 30 ng/mL as the upper limit of normal for serum 7HCO when compared with all other patients. Of 813 patients, 196 tested positive. Serum 7HCO levels were significantly higher in blood specimens that were collected between 12:00 and 13:00 (median 24 ng/mL) than in specimens collected between 09:00 and 10:00 (median 17 ng/mL) (P<0.05). CONCLUSION: Serum 7HCO testing is a simple, sensitive, noninvasive, inexpensive alternative to other more commonly used tests for BAM. Time of specimen collection, however, resulted in small but significant result variations and, although unlikely to have much impact on test value, it should ideally be standardized. PMID:21766092

  12. Serum transferrin receptor status of healthy adult Arabs.

    PubMed

    Knox-Macaulay, Huxley; Gravell, David; Elender, Frances

    2007-01-01

    Several studies have provided reference ranges for the concentration of serum transferrin receptor (sTfR) in various white populations, but there is a dearth of relevant reference sTfR data in non-whites. The aim of this investigation was to establish sTfR reference ranges and mean values for a healthy non-white Arab population that could be used also for Arabs worldwide. sTfR and serum ferritin concentrations were estimated by immunoassays and blood counts were determined by conventional methods. Analysis of the data of 114 volunteer Arab blood donors (91 male, 23 female) revealed a higher mean sTfR concentration in males of 22.6+/-8.1 nmol/L (range 10.9-38.7 nmol/L) compared to that in females of 18.7+/-4.4 nmol/L (range 10.7-25.8 nmol/L, p=0.001). There was no significant correlation of sTfR concentration with age, serum ferritin level, or blood haemoglobin level, but a strong inverse correlation was demonstrated with mean cell volume and mean cell haemoglobin of red cells. Iron-replete volunteer subjects with alpha-thalassaemia trait appear to have relatively high mean sTfR concentration. We recommend the use of gender-dependent sTfR reference values for Arabs.

  13. Proteomic Identification of Monoclonal Antibodies from Serum

    PubMed Central

    2015-01-01

    Characterizing the in vivo dynamics of the polyclonal antibody repertoire in serum, such as that which might arise in response to stimulation with an antigen, is difficult due to the presence of many highly similar immunoglobulin proteins, each specified by distinct B lymphocytes. These challenges have precluded the use of conventional mass spectrometry for antibody identification based on peptide mass spectral matches to a genomic reference database. Recently, progress has been made using bottom-up analysis of serum antibodies by nanoflow liquid chromatography/high-resolution tandem mass spectrometry combined with a sample-specific antibody sequence database generated by high-throughput sequencing of individual B cell immunoglobulin variable domains (V genes). Here, we describe how intrinsic features of antibody primary structure, most notably the interspersed segments of variable and conserved amino acid sequences, generate recurring patterns in the corresponding peptide mass spectra of V gene peptides, greatly complicating the assignment of correct sequences to mass spectral data. We show that the standard method of decoy-based error modeling fails to account for the error introduced by these highly similar sequences, leading to a significant underestimation of the false discovery rate. Because of these effects, antibody-derived peptide mass spectra require increased stringency in their interpretation. The use of filters based on the mean precursor ion mass accuracy of peptide-spectrum matches is shown to be particularly effective in distinguishing between “true” and “false” identifications. These findings highlight important caveats associated with the use of standard database search and error-modeling methods with nonstandard data sets and custom sequence databases. PMID:24684310

  14. A high-performance liquid chromatography method for the serotonin release assay is equivalent to the radioactive method.

    PubMed

    Sono-Koree, N K; Crist, R A; Frank, E L; Rodgers, G M; Smock, K J

    2016-02-01

    The serotonin release assay (SRA) is considered the gold standard laboratory test for heparin-induced thrombocytopenia (HIT). The historic SRA method uses platelets loaded with radiolabeled serotonin to evaluate platelet activation by HIT immune complexes. However, a nonradioactive method is desirable. We report the performance characteristics of a high-performance liquid chromatography (HPLC) SRA method. We validated the performance characteristics of an HPLC-SRA method, including correlation with a reference laboratory using the radioactive method. Serotonin released from reagent platelets was quantified by HPLC using fluorescent detection. Results were expressed as % release and classified as positive, negative, or indeterminate based on previously published cutoffs. Serum samples from 250 subjects with suspected HIT were tested in the HPLC-SRA and with the radioactive method. Concordant classifications were observed in 230 samples (92%). Sera from 41 healthy individuals tested negative. Between-run imprecision studies showed standard deviation of <6 (% release) for positive, weak positive, and negative serum pools. Stability studies demonstrated stability after two freeze-thaw cycles or up to a week of refrigeration. The HPLC-SRA has robust performance characteristics, equivalent to the historic radioactive method, but avoids the complexities of working with radioactivity. © 2015 John Wiley & Sons Ltd.

  15. Target analyte quantification by isotope dilution LC-MS/MS directly referring to internal standard concentrations--validation for serum cortisol measurement.

    PubMed

    Maier, Barbara; Vogeser, Michael

    2013-04-01

    Isotope dilution LC-MS/MS methods used in the clinical laboratory typically involve multi-point external calibration in each analytical series. Our aim was to test the hypothesis that determination of target analyte concentrations directly derived from the relation of the target analyte peak area to the peak area of a corresponding stable isotope labelled internal standard compound [direct isotope dilution analysis (DIDA)] may be not inferior to conventional external calibration with respect to accuracy and reproducibility. Quality control samples and human serum pools were analysed in a comparative validation protocol for cortisol as an exemplary analyte by LC-MS/MS. Accuracy and reproducibility were compared between quantification either involving a six-point external calibration function, or a result calculation merely based on peak area ratios of unlabelled and labelled analyte. Both quantification approaches resulted in similar accuracy and reproducibility. For specified analytes, reliable analyte quantification directly derived from the ratio of peak areas of labelled and unlabelled analyte without the need for a time consuming multi-point calibration series is possible. This DIDA approach is of considerable practical importance for the application of LC-MS/MS in the clinical laboratory where short turnaround times often have high priority.

  16. Simultaneous determination of phosphatidylcholine-derived quaternary ammonium compounds by a LC-MS/MS method in human blood plasma, serum and urine samples.

    PubMed

    Steuer, Christian; Schütz, Philipp; Bernasconi, Luca; Huber, Andreas R

    2016-01-01

    The determination of circulating trimethylamine-N-oxide (TMAO), choline, betaine, l-carnitine and O-acetyl-l-carnitine concentration in different human matrices is of great clinical interest. Recent results highlighted the prognostic value of TMAO and quaternary ammonium containing metabolites in the field of cardiovascular and kidney diseases. Herein, we report a method for the rapid and simultaneous measurement of closely related phosphatidylcholine-derived metabolites in three different biological matrices by stable isotope dilution assay. Plasma, serum and urine samples were simply deproteinized and separated by HILIC-chromatography. Detection and quantification were performed using LC-MS/MS with electrospray ionization in positive mode. For accuracy and precision, full calibration was performed covering more than the full reference range. Assay performance metrics include intra- and interday imprecision were below 10% for all analytes. To exclude matrix effects standard addition methods were applied for all matrices. It was shown that calibration standards and quality control prepared in water can be used instead of matrix-matched calibration and controls. The LC/MS/MS-based assay described in this article may improve future clinical studies evaluating TMAO and related substances as prognostic markers for cardiovascular risk and all-cause mortality in different patient populations. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Serum fructosamine concentrations in 59 dogs naturally Infected with Angiostrongylus vasorum.

    PubMed

    Willesen, J L; Jensen, A L; Kristensen, A T; Kjelgaard-Hansen, M; Jessen, R; Koch, J

    2006-06-01

    Retrospectively, 89 cases of dogs infected with Angiostrongylus vasorum were examined. Fifty-nine of these 89 dogs fulfilled the criteria of not being dually infected with Crenosoma vulpis as well as having a full biochemistry profile including serum fructosamine available. The mean serum fructosamine value of the 59 dogs was 236 micromol/l (reference value 258-348 micromol/l) and significantly lower than the serum fructosamine level of 314 micromol/l in a control group of 42 clinically healthy dogs. Eleven dogs were available for follow up after successful treatment of angiostrongylosis. In this group, the serum fructosamine value rose from a mean of 244 micromol/l to a mean of 320 micromol/l following treatment. Serum glucose, albumin and protein were all within the respective reference ranges at all sampling points. The results indicate that serum fructosamine could be affected by infection with A. vasorum. Furthermore, this change cannot be explained by measurable changes in the level of glucose, albumin or protein. The clinical impact of this study is that a low fructosamine value may indicate infection with A. vasorum thereby suggesting a Baermann test to be performed.

  18. Circulating 25-hydroxyvitamin D and the risk of rarer cancers: Design and methods of the Cohort Consortium Vitamin D Pooling Project of Rarer Cancers.

    PubMed

    Gallicchio, Lisa; Helzlsouer, Kathy J; Chow, Wong-Ho; Freedman, D Michal; Hankinson, Susan E; Hartge, Patricia; Hartmuller, Virginia; Harvey, Chinonye; Hayes, Richard B; Horst, Ronald L; Koenig, Karen L; Kolonel, Laurence N; Laden, Francine; McCullough, Marjorie L; Parisi, Dominick; Purdue, Mark P; Shu, Xiao-Ou; Snyder, Kirk; Stolzenberg-Solomon, Rachael Z; Tworoger, Shelley S; Varanasi, Arti; Virtamo, Jarmo; Wilkens, Lynne R; Xiang, Yong-Bing; Yu, Kai; Zeleniuch-Jacquotte, Anne; Zheng, Wei; Abnet, Christian C; Albanes, Demetrius; Bertrand, Kimberly; Weinstein, Stephanie J

    2010-07-01

    The Cohort Consortium Vitamin D Pooling Project of Rarer Cancers (VDPP), a consortium of 10 prospective cohort studies from the United States, Finland, and China, was formed to examine the associations between circulating 25-hydroxyvitamin D (25(OH)D) concentrations and the risk of rarer cancers. Cases (total n = 5,491) included incident primary endometrial (n = 830), kidney (n = 775), ovarian (n = 516), pancreatic (n = 952), and upper gastrointestinal tract (n = 1,065) cancers and non-Hodgkin lymphoma (n = 1,353) diagnosed in the participating cohorts. At least 1 control was matched to each case on age, date of blood collection (1974-2006), sex, and race/ethnicity (n = 6,714). Covariate data were obtained from each cohort in a standardized manner. The majority of the serum or plasma samples were assayed in a central laboratory using a direct, competitive chemiluminescence immunoassay on the DiaSorin LIAISON platform (DiaSorin, Inc., Stillwater, Minnesota). Masked quality control samples included serum standards from the US National Institute of Standards and Technology. Conditional logistic regression analyses were conducted using clinically defined cutpoints, with 50-<75 nmol/L as the reference category. Meta-analyses were also conducted using inverse-variance weights in random-effects models. This consortium approach permits estimation of the association between 25(OH)D and several rarer cancers with high accuracy and precision across a wide range of 25(OH)D concentrations.

  19. Circulating 25-Hydroxyvitamin D and the Risk of Rarer Cancers: Design and Methods of the Cohort Consortium Vitamin D Pooling Project of Rarer Cancers

    PubMed Central

    Gallicchio, Lisa; Helzlsouer, Kathy J.; Chow, Wong-Ho; Freedman, D. Michal; Hankinson, Susan E.; Hartge, Patricia; Hartmuller, Virginia; Harvey, Chinonye; Hayes, Richard B.; Horst, Ronald L.; Koenig, Karen L.; Kolonel, Laurence N.; Laden, Francine; McCullough, Marjorie L.; Parisi, Dominick; Purdue, Mark P.; Shu, Xiao-Ou; Snyder, Kirk; Stolzenberg-Solomon, Rachael Z.; Tworoger, Shelley S.; Varanasi, Arti; Virtamo, Jarmo; Wilkens, Lynne R.; Xiang, Yong-Bing; Yu, Kai; Zeleniuch-Jacquotte, Anne; Zheng, Wei; Abnet, Christian C.; Albanes, Demetrius; Bertrand, Kimberly; Weinstein, Stephanie J.

    2010-01-01

    The Cohort Consortium Vitamin D Pooling Project of Rarer Cancers (VDPP), a consortium of 10 prospective cohort studies from the United States, Finland, and China, was formed to examine the associations between circulating 25-hydroxyvitamin D (25(OH)D) concentrations and the risk of rarer cancers. Cases (total n = 5,491) included incident primary endometrial (n = 830), kidney (n = 775), ovarian (n = 516), pancreatic (n = 952), and upper gastrointestinal tract (n = 1,065) cancers and non-Hodgkin lymphoma (n = 1,353) diagnosed in the participating cohorts. At least 1 control was matched to each case on age, date of blood collection (1974–2006), sex, and race/ethnicity (n = 6,714). Covariate data were obtained from each cohort in a standardized manner. The majority of the serum or plasma samples were assayed in a central laboratory using a direct, competitive chemiluminescence immunoassay on the DiaSorin LIAISON platform (DiaSorin, Inc., Stillwater, Minnesota). Masked quality control samples included serum standards from the US National Institute of Standards and Technology. Conditional logistic regression analyses were conducted using clinically defined cutpoints, with 50–<75 nmol/L as the reference category. Meta-analyses were also conducted using inverse-variance weights in random-effects models. This consortium approach permits estimation of the association between 25(OH)D and several rarer cancers with high accuracy and precision across a wide range of 25(OH)D concentrations. PMID:20562188

  20. Development and evaluation of a recombinant-glycoprotein-based latex agglutination test for rabies virus antibody assessment.

    PubMed

    Jemima, Ebenezer Angel; Manoharan, Seeralan; Kumanan, Kathaperumal

    2014-08-01

    The measurement of neutralizing antibodies induced by the glycoprotein of rabies virus is indispensable for assessing the level of neutralizing antibodies in animals or humans. A rapid fluorescent focus inhibition test (RFFIT) has been approved by WHO and is the most widely used method to measure the virus-neutralizing antibody content in serum, but a rapid test system would be of great value to screen large numbers of serum samples. To develop and evaluate a latex agglutination test (LAT) for measuring rabies virus antibodies, a recombinant glycoprotein was expressed in an insect cell system and purified, and the protein was coated onto latex beads at concentrations of 0.1, 0.25, 0.5, 0.75, and 1 mg/ml to find out the optimal concentration for coating latex beads. It was found that 0.5 mg/ml of recombinant protein was optimal for coating latex beads, and this concentration was used to sensitize the latex beads for screening of dog serum samples. Grading of LAT results was done with standard reference serum with known antibody titers. A total of 228 serum samples were tested, out of which 145 samples were positive by both RFFIT and LAT, and the specificity was found to be 100 %. In RFFIT, 151 samples were positive, the sensitivity was found to be 96.03 %, and the accuracy/concordance was found to be 97.39 %. A rapid field test-a latex agglutination test (LAT)-was developed and evaluated for rabies virus antibody assessment using recombinant glycoprotein of rabies virus expressed in an insect cell system.

  1. Potential protective effect of honey against paracetamol-induced hepatotoxicity.

    PubMed

    Galal, Reem M; Zaki, Hala F; Seif El-Nasr, Mona M; Agha, Azza M

    2012-11-01

    Paracetamol overdose causes severe hepatotoxicity that leads to liver failure in both humans and experimental animals. The present study investigates the protective effect of honey against paracetamol-induced hepatotoxicity in Wistar albino rats. We have used silymarin as a standard reference hepatoprotective drug. Hepatoprotective activity was assessed by measuring biochemical parameters such as the liver function enzymes, serum alanine aminotransferase (ALT) and serum aspartate aminotransferase (AST). Equally, comparative effects of honey on oxidative stress biomarkers such as malondialdyhyde (MDA), reduced glutathione (GSH) and glutathione peroxidase (GPx) were also evaluated in the rat liver homogenates.  We estimated the effect of honey on serum levels and hepatic content of interleukin-1beta (IL-1β) because the initial event in paracetamol-induced hepatotoxicity has been shown to be a toxic-metabolic injury that leads to hepatocyte death, activation of the innate immune response and upregulation of inflammatory cytokines. Paracetamol caused marked liver damage as noted by significant increased activities of serum AST and ALT as well as the level of Il-1β. Paracetamol also resulted in a significant decrease in liver GSH content and GPx activity which paralleled an increase in Il-1β and MDA levels. Pretreatment with honey and silymarin prior to the administration of paracetamol significantly prevented the increase in the serum levels of hepatic enzyme markers, and reduced both oxidative stress and inflammatory cytokines. Histopathological evaluation of the livers also revealed that honey reduced the incidence of paracetamol-induced liver lesions. Honey can be used as an effective hepatoprotective agent against paracetamol-induced liver damage.

  2. Correlation analysis of two serum-specific immunoglobulin E test systems and skin-prick test in allergic rhinitis patients from northeast China.

    PubMed

    Jiang, Xiao-Dan; Li, Guang-Yu; Dong, Zhen; Zhu, Dong-Dong

    2011-01-01

    Skin-prick testing (SPT) is the most common screening method for allergy evaluation. The detection of serum-specific immunoglobulin E (sIgE) is also commonly used. The sensitivity and specificity of these testing methods may vary due to type of causative allergen and type of allergic manifestation. The purpose of this study was to evaluate the correlation between two methods of measuring sIgE (AllergyScreen [Mediwiss Analytic GmbH, Moers, Germany] and ImmunoCAP [Pharmacia, Uppsala, Sweden]) and SPT for the diagnosis of allergic rhinitis (AR). All 216 patients who were referred to the allergist for suspected AR from June to October 2009 had SPT and the two serological tests. One hundred fifty-eight patients had a positive clinical history and a related positive SPT. The SPT was used as reference standard, and we selected three allergens (Dermatophagoides pteronyssinus, mugwort, and ragweed), which were common in fall in northeast China, to analyze the correlation of the two serum tests and SPT. Compared with the SPT, the diagnostic indexes (accuracy, sensitivity and specificity) of the AllergyScreen system and the ImmunoCAP system were 0.819 versus 0.810, 0.780 versus 0.872, and 0.862 versus 0.741, respectively. The accuracy was similar between the two systems (p > 0.05). The ImmunoCAP system method had a higher sensitivity (p < 0.01). The AllergyScreen system had a higher specificity (p < 0.01). These data support that the AllergyScreen system and ImmunoCAP system can identify potentially significant allergens in the diagnosis of AR in patients from northeastern China.

  3. Effect of celecoxib plus standard chemotherapy on serum levels of vascular endothelial growth factor and cyclooxygenase-2 in patients with gastric cancer.

    PubMed

    Han, Xiaopeng; Li, Hongtao; Su, Lin; Zhu, Wankun; Xu, Wei; Li, Kun; Zhao, Qingchuan; Yang, Hua; Liu, Hongbin

    2014-03-01

    Elevated serum levels of vascular endothelial growth factor (VEGF) and cyclooxygenase-2 (COX-2) are associated with poor prognosis in patients with gastric cancer. Little is known regarding the clinical benefits of combining celecoxib, a selective inhibitor of COX-2, with standard chemotherapy regimens for the treatment of gastric cancer patients. In this study, we investigated the effect of the combinatorial use of celecoxib with standard chemotherapy on the serum levels of VEGF and COX-2 in patients with gastric cancer. In our study, 80 patients with gastric cancer who underwent laparoscopic radical surgery were randomized into two groups, the combination [celecoxib plus standard oxaliplatin, leucovorin and 5-fluorouracil (FOLFOX4) chemotherapy, n=40] and the FOLFOX4 alone (n=40) groups. In the combination group, celecoxib was orally administered to the patients (400 mg, twice daily). The serum levels of VEGF and COX-2 were measured by ELISA prior to and following surgery. We detected no significant difference in the serum levels of VEGF and COX-2 between the combination and FOLFOX4 alone groups prior to chemotherapy (P>0.05). However, after 6 cycles of chemotherapy, there was a greater decrease in the serum levels of VEGF and COX-2 in the combination group compared to those in the FOLFOX4 group (P<0.01). In addition, the serum levels of VEGF and COX-2 were closely correlated in patients with gastric adenocarcinoma prior to treatment. Our data indicated that, when combined with standard chemotherapy, celecoxib may reduce the serum levels of VEGF and COX-2, suggesting that COX-2 inhibitors may be of therapeutic value through the inhibition of tumor angiogenesis and the prevention of recurrence or metastasis. Thus, celecoxib may be a useful adjuvant agent to standard chemotherapy in patients with advanced gastric cancer.

  4. Nationwide Multicenter Reference Interval Study for 28 Common Biochemical Analytes in China.

    PubMed

    Xia, Liangyu; Chen, Ming; Liu, Min; Tao, Zhihua; Li, Shijun; Wang, Liang; Cheng, Xinqi; Qin, Xuzhen; Han, Jianhua; Li, Pengchang; Hou, Li'an; Yu, Songlin; Ichihara, Kiyoshi; Qiu, Ling

    2016-03-01

    A nationwide multicenter study was conducted in the China to explore sources of variation of reference values and establish reference intervals for 28 common biochemical analytes, as a part of the International Federation of Clinical Chemistry and Laboratory Medicine, Committee on Reference Intervals and Decision Limits (IFCC/C-RIDL) global study on reference values. A total of 3148 apparently healthy volunteers were recruited in 6 cities covering a wide area in China. Blood samples were tested in 2 central laboratories using Beckman Coulter AU5800 chemistry analyzers. Certified reference materials and value-assigned serum panel were used for standardization of test results. Multiple regression analysis was performed to explore sources of variation. Need for partition of reference intervals was evaluated based on 3-level nested ANOVA. After secondary exclusion using the latent abnormal values exclusion method, reference intervals were derived by a parametric method using the modified Box-Cox formula. Test results of 20 analytes were made traceable to reference measurement procedures. By the ANOVA, significant sex-related and age-related differences were observed in 12 and 12 analytes, respectively. A small regional difference was observed in the results for albumin, glucose, and sodium. Multiple regression analysis revealed BMI-related changes in results of 9 analytes for man and 6 for woman. Reference intervals of 28 analytes were computed with 17 analytes partitioned by sex and/or age. In conclusion, reference intervals of 28 common chemistry analytes applicable to Chinese Han population were established by use of the latest methodology. Reference intervals of 20 analytes traceable to reference measurement procedures can be used as common reference intervals, whereas others can be used as the assay system-specific reference intervals in China.

  5. Nationwide Multicenter Reference Interval Study for 28 Common Biochemical Analytes in China

    PubMed Central

    Xia, Liangyu; Chen, Ming; Liu, Min; Tao, Zhihua; Li, Shijun; Wang, Liang; Cheng, Xinqi; Qin, Xuzhen; Han, Jianhua; Li, Pengchang; Hou, Li’an; Yu, Songlin; Ichihara, Kiyoshi; Qiu, Ling

    2016-01-01

    Abstract A nationwide multicenter study was conducted in the China to explore sources of variation of reference values and establish reference intervals for 28 common biochemical analytes, as a part of the International Federation of Clinical Chemistry and Laboratory Medicine, Committee on Reference Intervals and Decision Limits (IFCC/C-RIDL) global study on reference values. A total of 3148 apparently healthy volunteers were recruited in 6 cities covering a wide area in China. Blood samples were tested in 2 central laboratories using Beckman Coulter AU5800 chemistry analyzers. Certified reference materials and value-assigned serum panel were used for standardization of test results. Multiple regression analysis was performed to explore sources of variation. Need for partition of reference intervals was evaluated based on 3-level nested ANOVA. After secondary exclusion using the latent abnormal values exclusion method, reference intervals were derived by a parametric method using the modified Box–Cox formula. Test results of 20 analytes were made traceable to reference measurement procedures. By the ANOVA, significant sex-related and age-related differences were observed in 12 and 12 analytes, respectively. A small regional difference was observed in the results for albumin, glucose, and sodium. Multiple regression analysis revealed BMI-related changes in results of 9 analytes for man and 6 for woman. Reference intervals of 28 analytes were computed with 17 analytes partitioned by sex and/or age. In conclusion, reference intervals of 28 common chemistry analytes applicable to Chinese Han population were established by use of the latest methodology. Reference intervals of 20 analytes traceable to reference measurement procedures can be used as common reference intervals, whereas others can be used as the assay system-specific reference intervals in China. PMID:26945390

  6. [An attempt for standardization of serum CA19-9 levels, in order to dissolve the gap between three different methods].

    PubMed

    Hayashi, Kuniki; Hoshino, Tadashi; Yanai, Mitsuru; Tsuchiya, Tatsuyuki; Kumasaka, Kazunari; Kawano, Kinya

    2004-06-01

    It is well known that serious method-related differences exist in results of serum CA19-9, and the necessity of standardization has been pointed out. In this study, differences of serum tumor marker CA19-9 levels obtained by various immunoassay kits (CLEIA, FEIA, LPIA and RIA) were evaluated in sixty-seven clinical samples and five calibrators and the possibility to improve the inter-methodological differences were observed not only for clinical samples but also for calibrators. We supposed an assumed standard material using by a calibrator. We calculated the serum levels of CA19-9 when using the assumed standard material for three different measurement methods. We approximate the CA19-9 values using by this method. It is suggested that the obtained CA19-9 values could be approximated by recalculation with the assumed standard material would be able to correct between-method and between-laboratory discrepancies in particular systematic errors.

  7. Lipid and Creatinine Adjustment to Evaluate Health Effects of Environmental Exposures.

    PubMed

    O'Brien, Katie M; Upson, Kristen; Buckley, Jessie P

    2017-03-01

    Urine- and serum-based biomarkers are useful for assessing individuals' exposure to environmental factors. However, variations in urinary creatinine (a measure of dilution) or serum lipid levels, if not adequately corrected for, can directly impact biomarker concentrations and bias exposure-disease association measures. Recent methodological literature has considered the complex relationships between creatinine or serum lipid levels, exposure biomarkers, outcomes, and other potentially relevant factors using directed acyclic graphs and simulation studies. The optimal measures of urinary dilution and serum lipids have also been investigated. Existing evidence supports the use of covariate-adjusted standardization plus creatinine adjustment for urinary biomarkers and standardization plus serum lipid adjustment for lipophilic, serum-based biomarkers. It is unclear which urinary dilution measure is best, but all serum lipid measures performed similarly. Future research should assess methods for pooled biomarkers and for studying diseases and exposures that affect creatinine or serum lipids directly.

  8. Lipid and Creatinine Adjustment to Evaluate Health Effects of Environmental Exposures

    PubMed Central

    O’Brien, Katie M.; Upson, Kristen; Buckley, Jessie P.

    2017-01-01

    Purpose of review Urine- and serum-based biomarkers are useful for assessing individuals’ exposure to environmental factors. However, variations in urinary creatinine (a measure of dilution) or serum lipid levels, if not adequately corrected for, can directly impact biomarker concentrations and bias exposure-disease association measures. Recent findings Recent methodological literature has considered the complex relationships between creatinine or serum lipid levels, exposure biomarkers, outcomes, and other potentially relevant factors using directed acyclic graphs and simulation studies. The optimal measures of urinary dilution and serum lipids have also been investigated. Summary Existing evidence supports the use of covariate-adjusted standardization plus creatinine adjustment for urinary biomarkers and standardization plus serum lipid adjustment for lipophilic, serum-based biomarkers. It is unclear which urinary dilution measure is best, but all serum lipid measures performed similarly. Future research should assess methods for pooled biomarkers and for studying diseases and exposures that affect creatinine or serum lipids directly. PMID:28097619

  9. Analysis of serum and cerebrospinal fluid in clinically normal adult miniature donkeys.

    PubMed

    Mozaffari, A A; Samadieh, H

    2013-09-01

    To establish reference intervals for serum and cerebrospinal fluid (CSF) parameters in clinically healthy adult miniature donkeys. Experiments were conducted on 10 female and 10 male clinically normal adult miniature donkeys, randomly selected from five herds. Lumbosacral CSF collection was performed with the sedated donkey in the standing position. Cell analysis was performed immediately after the samples were collected. Blood samples were obtained from the jugular vein immediately after CSF sample collection. Sodium, potassium, glucose, urea nitrogen, total protein, calcium, chloride, phosphorous and magnesium concentrations were measured in CSF and serum samples. A paired t-test was used to compare mean values between female and male donkeys. The CSF was uniformly clear, colourless and free from flocculent material, with a specific gravity of 1.002. The range of total nucleated cell counts was 2-4 cells/μL. The differential white cell count comprised only small lymphocytes. No erythrocytes or polymorphonuclear cells were observed on cytological examination. Reference values were obtained for biochemical analysis of serum and CSF. Gender had no effect on any variables measured in serum or CSF (p>0.05). CSF analysis can provide important information in addition to that gained by clinical examination. CSF analysis has not previously been performed in miniature donkeys; this is the first report on the subject. In the present study, reference intervals for total nucleated cell count, total protein, glucose, urea nitrogen, sodium, potassium, chloride, calcium, phosphorous and magnesium concentrations of serum and CSF were determined for male and female miniature donkeys.

  10. Development and Validation of a Rapid (13)C6-Glucose Isotope Dilution UPLC-MRM Mass Spectrometry Method for Use in Determining System Accuracy and Performance of Blood Glucose Monitoring Devices.

    PubMed

    Matsunami, Risë K; Angelides, Kimon; Engler, David A

    2015-05-18

    There is currently considerable discussion about the accuracy of blood glucose concentrations determined by personal blood glucose monitoring systems (BGMS). To date, the FDA has allowed new BGMS to demonstrate accuracy in reference to other glucose measurement systems that use the same or similar enzymatic-based methods to determine glucose concentration. These types of reference measurement procedures are only comparative in nature and are subject to the same potential sources of error in measurement and system perturbations as the device under evaluation. It would be ideal to have a completely orthogonal primary method that could serve as a true standard reference measurement procedure for establishing the accuracy of new BGMS. An isotope-dilution liquid chromatography/mass spectrometry (ID-UPLC-MRM) assay was developed using (13)C6-glucose as a stable isotope analogue to specifically measure glucose concentration in human plasma, and validated for use against NIST standard reference materials, and against fresh isolates of whole blood and plasma into which exogenous glucose had been spiked. Assay performance was quantified to NIST-traceable dry weight measures for both glucose and (13)C6-glucose. The newly developed assay method was shown to be rapid, highly specific, sensitive, accurate, and precise for measuring plasma glucose levels. The assay displayed sufficient dynamic range and linearity to measure across the range of both normal and diabetic blood glucose levels. Assay performance was measured to within the same uncertainty levels (<1%) as the NIST definitive method for glucose measurement in human serum. The newly developed ID UPLC-MRM assay can serve as a validated reference measurement procedure to which new BGMS can be assessed for glucose measurement performance. © 2015 Diabetes Technology Society.

  11. Development and Validation of a Rapid 13C6-Glucose Isotope Dilution UPLC-MRM Mass Spectrometry Method for Use in Determining System Accuracy and Performance of Blood Glucose Monitoring Devices

    PubMed Central

    Matsunami, Risë K.; Angelides, Kimon; Engler, David A.

    2015-01-01

    Background: There is currently considerable discussion about the accuracy of blood glucose concentrations determined by personal blood glucose monitoring systems (BGMS). To date, the FDA has allowed new BGMS to demonstrate accuracy in reference to other glucose measurement systems that use the same or similar enzymatic-based methods to determine glucose concentration. These types of reference measurement procedures are only comparative in nature and are subject to the same potential sources of error in measurement and system perturbations as the device under evaluation. It would be ideal to have a completely orthogonal primary method that could serve as a true standard reference measurement procedure for establishing the accuracy of new BGMS. Methods: An isotope-dilution liquid chromatography/mass spectrometry (ID-UPLC-MRM) assay was developed using 13C6-glucose as a stable isotope analogue to specifically measure glucose concentration in human plasma, and validated for use against NIST standard reference materials, and against fresh isolates of whole blood and plasma into which exogenous glucose had been spiked. Assay performance was quantified to NIST-traceable dry weight measures for both glucose and 13C6-glucose. Results: The newly developed assay method was shown to be rapid, highly specific, sensitive, accurate, and precise for measuring plasma glucose levels. The assay displayed sufficient dynamic range and linearity to measure across the range of both normal and diabetic blood glucose levels. Assay performance was measured to within the same uncertainty levels (<1%) as the NIST definitive method for glucose measurement in human serum. Conclusions: The newly developed ID UPLC-MRM assay can serve as a validated reference measurement procedure to which new BGMS can be assessed for glucose measurement performance. PMID:25986627

  12. Serum reference value of two potential doping candidates-myostatin and insulin-like growth factor-I in the healthy young male.

    PubMed

    Han, Der-Sheng; Huang, Chi-Huang; Chen, Ssu-Yuan; Yang, Wei-Shiung

    2017-01-01

    Myostatin negatively regulates muscle growth, and its inhibition by suitable proteins can increase muscle bulk and exercise performance. However, the reference values of serum myostatin in athletes performing strength training are still lacking. A cross-sectional study recruiting28 male collegiate athletes performing strength training and 29 age-matched normal controls was conducted. The serum concentration of myostatin and insulin-like growth factor 1 (IGF-1), grip strength, and body composition were the main outcome measures. We used regression models to analyze the correlation between serum markers and the physiological parameters. The athlete group had greater height, weight, body mass index (BMI), fat mass percentage, fat-free mass, muscle mass, waist girth, grip strength, and estimated daily energy expenditure. The IGF-1 concentration was higher in the athlete group (324 ± 80 vs. 263 ± 134 ng/ml), but the myostatin levels did not differ (12.1 ± 3.7 vs. 12.4 ± 3.5 ng/ml). The reference value for IGF-1 among the healthy young males was 293 ± 114 ng/ml, correlated with age and height; the value for myostatin was 12.3 ± 3.6 ng/ml, correlated negatively with BMI, fat mass percentage, and waist girth after adjustment for age. Myostatin level is negatively related to fat percentage, and serum IGF-1 is positively related to height. The reference values could provide a basis for future doping-related study.

  13. Serum chemistry reference ranges for Steller sea lion (Eumetopias jubatus) pups from Alaska: stock differentiation and comparisons within a North Pacific sentinel species.

    PubMed

    Lander, Michelle E; Fadely, Brian S; Gelatt, Thomas S; Rea, Lorrie D; Loughlin, Thomas R

    2013-12-01

    Blood chemistry and hematologic reference ranges are useful for population health assessment and establishing a baseline for future comparisons in the event of ecosystem changes due to natural or anthropogenic factors. The objectives of this study were to determine if there was any population spatial structure for blood variables of Steller sea lion (Eumetopias jubatus), an established sentinel species, and to report reference ranges for appropriate populations using standardized analyses. In addition to comparing reference ranges between populations with contrasting abundance trends, data were examined for evidence of disease or nutritional stress. From 1998 to 2011, blood samples were collected from 1,231 pups captured on 37 rookeries across their Alaskan range. Reference ranges are reported separately for the western and eastern distinct population segments (DPS) of Steller sea lion after cluster analysis and discriminant function analysis (DFA) supported underlying stock structure. Variables with greater loading scores for the DFA (creatinine, total protein, calcium, albumin, cholesterol, and alkaline phosphatase) also were greater for sea lions from the endangered western DPS, supporting previous studies that indicated pup condition in the west was not compromised during the first month postpartum. Differences between population segments were likely a result of ecological, physiological, or age related differences.

  14. Effect of Silitidil, a standardized extract of milk thistle, on the serum prolactin levels in female rats.

    PubMed

    Capasso, Raffaele

    2014-07-01

    The aim of this study was to assess the effect of Silitidil, a standardized extract of milk thistle, on the serum levels of prolactin in female rats. A 14-day treatment with Silitidil (25-200 mg/kg, per os), a standardized extract of Silybum marianum fruits (milk thistle), increased, in a dose dependent manner, the serum prolactin levels in female rats. Galega (200 mg/kg, per os) given alone neither modified the basal levels of prolactin nor increased further serum prolactin levels when associated with Silitidil. Bromocriptine (1 mg/kg, per os) significantly reduced the high serum prolactin levels induced by Silitidil (200 mg/kg, per os). The results show that the extract of S. marianum fruits significantly increases prolactin levels in female rats; this effect is not potentiated by galega and seems to involve, at least in part, dopamine D2 receptors.

  15. Environmental Chemicals in Urine and Blood: Improving Methods for Creatinine and Lipid Adjustment.

    PubMed

    O'Brien, Katie M; Upson, Kristen; Cook, Nancy R; Weinberg, Clarice R

    2016-02-01

    Investigators measuring exposure biomarkers in urine typically adjust for creatinine to account for dilution-dependent sample variation in urine concentrations. Similarly, it is standard to adjust for serum lipids when measuring lipophilic chemicals in serum. However, there is controversy regarding the best approach, and existing methods may not effectively correct for measurement error. We compared adjustment methods, including novel approaches, using simulated case-control data. Using a directed acyclic graph framework, we defined six causal scenarios for epidemiologic studies of environmental chemicals measured in urine or serum. The scenarios include variables known to influence creatinine (e.g., age and hydration) or serum lipid levels (e.g., body mass index and recent fat intake). Over a range of true effect sizes, we analyzed each scenario using seven adjustment approaches and estimated the corresponding bias and confidence interval coverage across 1,000 simulated studies. For urinary biomarker measurements, our novel method, which incorporates both covariate-adjusted standardization and the inclusion of creatinine as a covariate in the regression model, had low bias and possessed 95% confidence interval coverage of nearly 95% for most simulated scenarios. For serum biomarker measurements, a similar approach involving standardization plus serum lipid level adjustment generally performed well. To control measurement error bias caused by variations in serum lipids or by urinary diluteness, we recommend improved methods for standardizing exposure concentrations across individuals.

  16. Establishing a reliable multiple reaction monitoring-based method for the quantification of obesity-associated comorbidities in serum and adipose tissue requires intensive clinical validation.

    PubMed

    Oberbach, Andreas; Schlichting, Nadine; Neuhaus, Jochen; Kullnick, Yvonne; Lehmann, Stefanie; Heinrich, Marco; Dietrich, Arne; Mohr, Friedrich Wilhelm; von Bergen, Martin; Baumann, Sven

    2014-12-05

    Multiple reaction monitoring (MRM)-based mass spectrometric quantification of peptides and their corresponding proteins has been successfully applied for biomarker validation in serum. The option of multiplexing offers the chance to analyze various proteins in parallel, which is especially important in obesity research. Here, biomarkers that reflect multiple comorbidities and allow monitoring of therapy outcomes are required. Besides the suitability of established MRM assays for serum protein quantification, it is also feasible for analysis of tissues secreting the markers of interest. Surprisingly, studies comparing MRM data sets with established methods are rare, and therefore the biological and clinical value of most analytes remains questionable. A MRM method using nano-UPLC-MS/MS for the quantification of obesity related surrogate markers for several comorbidities in serum, plasma, visceral and subcutaneous adipose tissue was established. Proteotypic peptides for complement C3, adiponectin, angiotensinogen, and plasma retinol binding protein (RBP4) were quantified using isotopic dilution analysis and compared to the standard ELISA method. MRM method variabilities were mainly below 10%. The comparison with other MS-based approaches showed a good correlation. However, large differences in absolute quantification for complement C3 and adiponectin were obtained compared to ELISA, while less marked differences were observed for angiotensinogen and RBP4. The verification of MRM in obesity was performed to discriminate first lean and obese phenotype and second to monitor excessive weight loss after gastric bypass surgery in a seven-month follow-up. The presented MRM assay was able to discriminate obese phenotype from lean and monitor weight loss related changes of surrogate markers. However, inclusion of additional biomarkers was necessary to interpret the MRM data on obesity phenotype properly. In summary, the development of disease-related MRMs should include a step of matching the MRM data with clinically approved standard methods and defining reference values in well-sized representative age, gender, and disease-matched cohorts.

  17. Clinical biochemistry, haematology and body weight in piglets.

    PubMed

    Egeli, A K; Framstad, T; Morberg, H

    1998-01-01

    Reference ranges for clinical biochemical parameters commonly investigated in pigs were determined in one- (day 1), 21- and 35-day old piglets. The mean and standard deviation were also estimated for body weight, and haematological and clinical biochemical parameters at these ages. The piglets were divided into 2 investigation groups according to whether they had a haemoglobin concentration < or = 80 g/l ("anaemic group") or > 80 g/l ("normal group") on days 14, 21 and 28. The "anaemic group" was compared to the "normal group" on days 21 and 35. Many of the clinical biochemical parameters varied according to age. Some of the enzymes had high average values and wide reference ranges in piglets, especially on day 1, compared to the reference ranges for sows given in the literature. The reference ranges for some of the metabolic parameters were broader on day 1 than later in the preweaning period. The reference ranges for albumin, total iron-binding capacity and serum iron were, however, lower and more narrow on day 1. On days 21 and 35, relatively high values for phosphorus must be considered "normal" compared to the figures given in the literature for adult pigs. The other minerals seemed to be quite unaffected of age, but some were affected by anaemia. The anaemic piglets had lower average serum iron but higher total iron-binding capacity than the "normal" piglets on days 21 and 35. However, variation between piglets gave wide reference ranges, indicating that these parameters will only have limited usefulness in detecting iron deficiency anaemia in piglets. The electrolytes seemed also to be affected by the existence of anaemia. The body weight and leukocyte counts were significantly lower in the "anaemic group" than the "normal group" on day 35, while the greatest differences in clinical biochemical parameters between the groups were found on day 21, when the piglets in the "anaemic group" were most severely anaemic. Although these piglets suffered from severe iron-deficiency anaemia, only a few clinical biochemical parameters were affected, and the differences between groups were mostly small.

  18. Association between Serum Uric Acid Level and Carotid Atherosclerosis in Chinese Individuals Aged 75 Years or Older: A Hospital-Based Case-Control Study.

    PubMed

    Feng, L; Hua, C; Sun, H; Qin, L-Y; Niu, P-P; Guo, Z-N; Yang, Y

    2018-01-01

    To investigate the association between serum uric acid level and the presence and progression of carotid atherosclerosis in Chinese individuals aged 75 years or older. Case-control study. In a teaching hospital. Five hundred and sixty-four elderlies (75 years or above) who underwent general health screening in our hospital were enrolled. The detailed carotid ultrasound results, physical examination information, medical history, and laboratory test results including serum uric acid level were recorded, these data were used to analyze the relationship between serum uric acid level and carotid atherosclerosis. Then, subjects who underwent the second carotid ultrasound 1.5-2 years later were further identified to analyzed the relationship between serum uric acid and the progression of carotid atherosclerosis. A total of 564 subjects were included, carotid plaque was found in 482 (85.5%) individuals. Logistic regression showed that subjects with elevated serum uric acid (expressed per 1 standard deviation change) had significantly higher incidence of carotid plaque (odds ratio, 1.37; 95% confidence interval, 1.07-1.75; P= 0.012) after controlling for other factors. A total of 236 subjects underwent the follow-up carotid ultrasound. Linear regression showed that serum uric acid level (expressed per 1 standard deviation change; 1 standard deviation = 95.5 μmol/L) was significantly associated with percentage of change of plaque score (P = 0.008). Multivariable linear regression showed that 1 standard deviation increase in serum uric acid levels was expected to increase 0.448% of plaque score (P = 0.023). The elevated serum uric acid level may be independently and significantly associated with the presence and progression of carotid atherosclerosis in Chinese individuals aged 75 years or older.

  19. Can urine dipstick predict an elevated serum creatinine?

    PubMed

    Shah, Kaushal; Kilian, Barbara; Hsieh, Wei-Jen; Kyrillou, Emily; Hedge, Vishal; Newman, David H

    2010-06-01

    Chart review studies have suggested that point-of-care urine dipstick testing may accurately predict an elevation in serum creatinine (Cr). We aimed to prospectively evaluate the test characteristics of proteinuria/hematuria in predicting elevated serum Cr. A prospective, observational study was conducted between March 2007 and June 2008 at 2 affiliated, urban hospitals with an annual emergency department census of 150,000. Patients undergoing laboratory urinalysis, point-of-care urine dipstick, and a serum chemistry panel were enrolled. Trained research assistants collected data on consecutive patients 18 hours per day using preformatted data forms and entry into an anonymized Access (Microsoft, Seattle, Wash) database. Demographic baseline variables including age, sex, chief complaint, vital signs, and source of sample (catheter vs "clean catch") were also collected. An elevated Cr level was defined as greater than 1.3 based on the laboratory reference range. Standard statistical methods were used to calculate diagnostic test operating characteristics of proteinuria or hematuria as a predictor of elevated serum Cr. Five thousand four hundred sixteen subjects were enrolled with 28.3% male and a mean age of 50.2 years. Elevated serum Cr greater than 1.3 mg/dL was found in 13.9% (755/5416) of subjects. The sensitivity of either proteinuria or hematuria for elevated Cr was 82.5% (95% confidence interval [CI], 80%-85%) and specificity was 34.4% (95% CI, 33%-36%). Positive predictive value was 16.9% (95% CI, 16%-18%) and negative predictive value was 92.4% (95% CI, 91-94%). The likelihood ratio for a positive test was 1.3 (95% CI, 1.1-1.5), and the likelihood ratio for a negative test was 0.5 (95% CI, 0.3-0.8). Although negative predictive value was high, the presence of proteinuria/hematuria was only moderately predictive of elevated serum Cr level. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  20. Evaluation of Serum Thyroid-Stimulating Hormone Concentration as a Diagnostic Test for Hyperthyroidism in Cats.

    PubMed

    Peterson, M E; Guterl, J N; Nichols, R; Rishniw, M

    2015-01-01

    In humans, measurement of serum thyroid-stimulating hormone (TSH) concentration is commonly used as a first-line discriminatory test of thyroid function. Recent reports indicate that canine TSH (cTSH) assays can be used to measure feline TSH and results can help diagnose or exclude hyperthyroidism. To investigate the usefulness of cTSH measurements as a diagnostic test for cats with hyperthyroidism. Nine hundred and seventeen cats with untreated hyperthyroidism, 32 euthyroid cats suspected of having hyperthyroidism, and 131 clinically normal cats. Prospective study. Cats referred to the Animal Endocrine Clinic for suspected hyperthyroidism were evaluated with serum T4, T3, free T4 (fT4), and TSH concentrations. Thyroid scintigraphy was used as the gold standard to confirm or exclude hyperthyroidism. Median serum TSH concentration in the hyperthyroid cats (<0.03 ng/mL) was significantly (P < .001) lower than concentrations in clinically normal cats (0.05 ng/mL) or euthyroid cats with suspected thyroid disease (0.06 ng/mL). Only 18 (2.0%) hyperthyroid cats had measurable TSH concentrations (≥0.03 ng/mL), whereas 114 (69.9%) of the 163 euthyroid cats had detectable concentrations. Combining serum TSH with T4 or fT4 concentrations lowered the test sensitivity of TSH from 98.0 to 97.0%, but markedly increased overall test specificity (from 69.9 to 98.8%). Serum TSH concentrations are suppressed in 98% of hyperthyroid cats, but concentrations are measurable in a few cats with mild-to-moderate hyperthyroidism. Measurement of serum TSH represents a highly sensitive but poorly specific test for diagnosis of hyperthyroidism and is best measured in combination with T4 and fT4. Copyright © 2015 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  1. [Effect of qinghuobaiduyin on the expression of high mobility group box chromosomal protein 1 in macrophage].

    PubMed

    Li, Ping; Xu, Dan; Luo, Chengqun

    2010-07-01

    To observe the expression of high mobility group box chromosomal protein 1(HMGB1) in RAW264.7 macrophages after interfering with burning serum and qinghuobaidu-yin (QHBDY), and to find out the endogenous protection mechanism of QHBDY resisting inflammation reaction. RT-PCR was used to detect the expression of HMGB1 in RAW264.7 macrophages after interfering RAW264.7 macrophages with normal SD rat serum, burning SD rat serum, and QHBDY feeding SD rat serum. Small quantity of HMGB1 mRNA was expressed in RAW264.7. The expression of HMGB1 mRNA fluctuated around the standard level after interfering with normal serum of SD rats. The expression of HMGB1 mRNA rose at 3 h, and then decreased to the standard level; at 18 h, it rose rapidly; at 36 h, it reached the peak; and at 48 h, it remained at the high level after interfering with burning serum. The expression of HMGB1 mRNA increased at 3 h, and then decreased to the standard level. At 24 h, it started to rise after interfering with herb serum, and was lower than that of; the burning serum group (P<0.05). Burning serum can increase the expression of HMGB1 mRNA in RAW264.7. QHBDY can decrease the high expression of HMGB1 mRNA in RAW264.7 caused by burning serum.

  2. Gastric Cancer Screening by Combined Determination of Serum Helicobacter pylori Antibody and Pepsinogen Concentrations: ABC Method for Gastric Cancer Screening.

    PubMed

    Chen, Xian-Zhe; Huang, Cheng-Zhi; Hu, Wei-Xian; Liu, Ying; Yao, Xue-Qing

    2018-05-20

    Gastroscopy combined with gastric mucosa biopsies is currently regarded as a gold standard for diagnosis of gastric cancer. However, its application is restricted in clinical practice due to its invasive property. A new noninvasive population screening process combining the assay of anti-Helicobacter pylori antibody and serum pepsinogen (PG) (ABC method) is adopted to recognize the high-risk patients for further endoscopy examination, avoiding the unnecessary gastroscopy for most population and saving the cost consumption for mass screening annually. Nevertheless, controversies exist for the grouping of ABC method and the intervals of gastroscopy surveillance for each group. In this review, we summarized these popular concerned topics for providing useful references to the healthcare practitioner in clinical practice. The PubMed databases were systematically searched from the inception dates to November 22, 2017, using the keywords "Helicobacter pylori," "Pepsinogens," and "Stomach Neoplasms." Original articles and reviews on the topics were selected. Anti-H. pylori antibody and serum PG concentration showed significant changes under the different status of H. pylori infection and the progression of atrophic gastritis, which can be used for risk stratification of gastric cancer in clinic. In addition, anti-H. pylori antibody titer can be used for further risk stratification of gastric cancer contributing to determine better endoscopy surveillance interval. The early detection and diagnosis of gastric cancer benefit from the risk stratification, but the cutoff values for H. pylori antibody and serum PG concentration require further modification.

  3. Pre-clinical validation study of a miniaturized electrochemical immunoassay based on square wave voltammetry for early detection of carcinoembryonic antigen in human serum.

    PubMed

    Martínez-Mancera, Flavio Dolores; García-López, Patricia; Hernández-López, José Luis

    2015-04-15

    The ELISA format for measuring carcinoembryonic antigen (CEA) serves as a reference standard against which other assays are compared. Because the World Health Organization (WHO) increasingly recommends the use of serum CEA as a diagnostic tool for cancer, it is relevant to explore the reliability of the new decentralized CEA point-of-care-testing (POCT) technologies that are available to physicians and patients, in compliance with mandates of the clinical laboratories' regulatory agencies. Electrochemical immunoassay (ECIA) based on trace lead (Pb) analysis by anodic stripping techniques using sandwich-type immunocomplex conjugates: (MB)Ab/AgCEA/Ab(PbS), and a commercial ELISA test system with optical transmission. The ECIA provides better analytical performance than does the ELISA. The within assay precision coefficient of variance (%CVw) of the ECIA is lower than the value recommended by the Hong Kong Association of Medical Laboratories (HKAML), and the recoveries of CEA at 1.0, 5.0, 10.0, 25.0 and 50.0 ng/ml are in the range of 99-110% for control serum samples. The ECIA showed a minimal positive bias of 0.0267 ± 0.3270 ng/ml (P=0.9389). The proposed CEA screening technology can be practically employed for decentralized clinical analysis of CEA in human serum. Therefore, it can be viewed as a control method for personalized therapy. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Serum biomarkers are similar in Churg-Strauss syndrome and hypereosinophilic syndrome

    PubMed Central

    Khoury, Paneez; Zagallo, Patricia; Talar-Williams, Cheryl; Santos, Carlo S.; Dinerman, Ellen; Holland, Nicole C.; Klion, Amy D.

    2012-01-01

    Rationale Churg-Strauss syndrome (CSS) and hypereosinophilic syndrome (HES) overlap considerably in clinical presentation. A reliable means of distinguishing between these groups of patients is needed, especially in the setting of glucocorticoid therapy. Methods A retrospective chart review of 276 adult subjects referred for evaluation of eosinophilia >1500/μl was performed, and subjects with a documented secondary cause of eosinophilia or a PDGFR-positive myeloproliferative neoplasm were excluded. The remaining subjects were assessed for the presence of American College of Rheumatology (ACR) criteria. Laboratory and clinical parameters were compared between subjects with biopsy-proven vasculitis (CSS; n=8), ≥4 ACR criteria (probable CSS; n=21), HES with asthma and/or sinusitis without other CSS-defining criteria (HESwAS; n=20), HES without asthma or sinusitis (HES; n=18), and normal controls (n=8). Serum biomarkers reported to be associated with CSS were measured using standard techniques. Results There were no differences between the subjects with definite or probable CSS or HES with respect to age, gender, or maintenance steroid dose. Serum CCL17, IL-8 and eotaxin levels were significantly increased in eosinophilic subjects as compared to normal controls, but were similar between the eosinophilic groups. Serum CCL17 correlated with eosinophil count (p<0.0001, r=0.73), but not with prednisone dose. Conclusions In patients with a history of asthma and sinusitis, distinguishing between ANCA-negative CSS and PDGFR-negative HES is difficult due to significant overlap in clinical presentation and biomarker profiles. PMID:22775568

  5. Age- and sex-specific reference values for fasting serum insulin levels and insulin resistance/sensitivity indices in healthy Iranian adults: Tehran Lipid and Glucose Study.

    PubMed

    Tohidi, Maryam; Ghasemi, Asghar; Hadaegh, Farzad; Derakhshan, Arash; Chary, Abdolreza; Azizi, Fereidoun

    2014-04-01

    Increased insulin concentration is a surrogate for insulin resistance and early assessment of fasting insulin may help in identifying those who are potentially at high risk of type 2 diabetes, hypertension, and cardiovascular disease. The aim of this study was to determine age- and sex-related reference values for serum insulin and insulin resistance/sensitivity indices in Iranian subjects. Serum insulin levels were measured by electrochemiluminescence immunoassay in 5786 participants of the Tehran Lipid and Glucose Study. After application of exclusion criteria, 309 non-obese healthy subjects (124 men and 185 women), aged 24-83 y, were included. The International Federation of Clinical Chemistry guidelines (non-parametric method) and the robust method were used for determining reference values. Overall 95% reference values for fasting insulin were 1.61-11.37, 2.34-11.98, and 2.11-12.49 μU/mL in men, women, and total population respectively. Mean fasting insulin concentration showed a decreasing trend with age in both genders (p for trend ≤0.001). Age, waist circumference, and systolic blood pressures were biological determinants of fasting insulin in both genders; in addition, insulin was modulated by triglycerides in men and fasting glucose in women. Reference intervals for HOMA1-IR, HOMA2-IR, and QUICKI were 0.63-2.68, 0.40-1.80, and 0.33-0.42, respectively. This study presents the first set of reference values for fasting serum insulin to be 2-12 μU/mL for both genders in a healthy sample of Iranian adults along with the reference values for insulin resistance/sensitivity indices. These values could be used for identifying subjects with insulin resistance in epidemiological and clinical research. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  6. Evaluation of an anal sac adenocarcinoma tumor in a Spitz dog.

    PubMed

    Javanbakht, Javad; Tavassoli, Abbas; Sabbagh, Atefeh; Hassan, Mehdy Aghamohammmad; Samakkhah, Shohreh Alian; Shafiee, Radmehr; Lakzian, Ali; Ghalee, Vahideh Rahmani; Gharebagh, Sonia Shoja

    2013-01-01

    A 9-year-old emasculated male Spitz with tenesmus and constipation had a subcutaneous mass at the left ventral aspect of the anus with history of polyuria and polydipsia. A complete blood cell count, serum biochemistry panel, and urinalysis (cystocentesis sample) were evaluated. Abnormalities in the serum biochemistry panel included a mildly elevated serum cholesterol concentration (7.28 mmol/L; reference interval, 2.70-5.94 mmol/L), increased serum alkaline phosphatase activity (184 U/L; reference interval, 9-90 U/L), alanine transaminase (122 U/L; reference interval, 5-60 U/L) activity and aspartate aminotransferase (80 U/L; reference interval, 5-55 U/L) activity, severe increased total calcium concentration (16.3 mg/dL; reference interval, 8.2-12.4 mg/dL or 9.3-11.4 mg/dL), and decreased total calcium concentration (3.4 mg/dL, reference interval, 2.5-5.6mg/dL). Furthermore, testing revealed an increased intact parathyroid hormone concentration (38.6 pmol/L; reference interval, 3-17 pmol/L). On cytologic and histopathologic examinations, various types of cells were observed. Most of the cells were oval to polygonal and had elliptical or elongate nuclei and a moderate amount of pale to basophilic cytoplasm. The remaining cells had round to oval nuclei and pale to basophilic cytoplasm. Cells of both types were loosely adhered to each other and were arranged in rosette-like structures. Both neoplastic cell types had fine homogenous chromatin and either a small indistinct nucleolus or no visible nucleolus. Mild anisokaryosis and anisocytosis were observed. Histologically, the mass consists of glandular structures formed by cuboidal cells admixed with bundles of spindle cells. Based on location and histologic features, the final diagnosis was adenocarcinoma of the apocrine gland of the anal sac, which should be included as a cytologic differential diagnosis when spindle cells and typical epithelial cells are observed in masses in the region of the anal sac of dogs.

  7. Novel lipoprotein density profiling in healthy dogs of various breeds, healthy miniature schnauzers, and miniature schnauzers with hyperlipidemia

    PubMed Central

    2013-01-01

    Background Despite the importance of abnormalities in lipoprotein metabolism in clinical canine medicine, the fact that most previously used methods for lipoprotein profiling are rather laborious and time-consuming has been a major obstacle to the wide clinical application and use of lipoprotein profiling in this species. The aim of the present study was to assess the feasibility of a continuous lipoprotein density profile (CLPDP) generated within a bismuth sodium ethylenediaminetetraacetic acid (NaBiEDTA) density gradient to characterize and compare the lipoprotein profiles of healthy dogs of various breeds, healthy Miniature Schnauzers, and Miniature Schnauzers with primary hypertriacylglycerolemia. A total of 35 healthy dogs of various breeds with serum triacylglycerol (TAG) and cholesterol concentrations within their respective reference intervals were selected for use as a reference population. Thirty-one Miniature Schnauzers with serum TAG and cholesterol concentrations within their respective reference intervals and 31 Miniature Schnauzers with hypertriacylglyceridemia were also included in the study. Results The results suggest that CLPDP using NaBiEDTA provides unique diagnostic information in addition to measurements of serum TAG and cholesterol concentrations and that it is a useful screening method for dogs with suspected lipoprotein metabolism disorders. Using the detailed and continuous density distribution information provided by the CLPDP, important differences in lipoprotein profiles can be detected even among dogs that have serum TAG and cholesterol concentrations within the reference interval. Miniature Schnauzers with serum TAG and cholesterol concentrations within the reference interval had significantly different lipoprotein profiles than dogs of various other breeds. In addition, it was further established that specific lipoprotein fractions are associated with hypertriacylglyceridemia in Miniature Schnauzers. Conclusions The results of the present study suggest that density gradient ultracentrifugation using NaBiEDTA is a useful screening method for the study of lipoprotein profiles in dogs. Therefore, this method could potentially be used for diagnostic purposes for the separation of dogs suspected of having lipoprotein abnormalities from healthy dogs. PMID:23497598

  8. Studies on acid-base status (Stewart's model) of young camels (Camelus dromedarius) after acid-load with NH4Cl.

    PubMed

    Elkhair, Nawal M; Hartmann, Helmut

    2010-01-01

    The identification of the reference values of Stewart variables and the changes in the acid-base status of the blood and urine in relation to the age after acid-load were studied in desert species of camels. 14 healthy young camels (age: 3-5 months) and 22 adult camels (age: 5-8 years) were used to provide the reference and percentile ranges of the Stewart variables. In the experiments, 24 healthy young camels (age: < 3-5 months) were infused with 5M NH4Cl solution (dose: 1.0 ml/kg) through a permanent intravenous catheter. Venous blood and urine samples were collected before infusion (0 hours). After the start of infusion, venous blood samples were collected at 2, 4, 6, 8 and 24 hours, and urine samples were collected at 8, 24 and 48 hours. Blood and urine samples were used for the determination of the various acid-base parameters, including the non-respiratory Stewart variables. The reference range of serum-[strong ion difference = SID3] was 39-52 mmol/l for all age groups. The reference values of serum-[acid total = A-] were between 10-17 mmol/l for all age groups. Serum-[Atotprotein] and -[Atot-albumin] showed a reference range of 19-24 mmol/I and 20-28 mmol/l, respectively. By 2-8 hours after the NH4Cl-load, the Stewart variables (serum-[SID3] and serum-[A(tot-protein)]) decreased significantly, and as a consequence, the blood pH decreased. Generally, the loaded young camels showed a transient moderate hyperchloraemic acidosis with a slight hypoproteinaemic alkalosis. These malfunctions were accompanied by increased renal fractional excretion of chloride and sodium and decreased urine pH. The identified reference values of the Stewart variables can be used for the clinical diagnosis of acid-base disturbances in camels. With the assistance of the non-respiratory Stewart variables ([SID3] and [Atot]), we can detect the determining influence of strong electrolytes (Na+, K+ and Cl-) and weak acids (proteins, Pi) on the physiological and pathological acid-base status of the animals.

  9. KEY COMPARISON: Final report on CCQM-K63.a,b: Non-peptide hormones in serum: cortisol and progesterone

    NASA Astrophysics Data System (ADS)

    S-C Tai, Susan; Duewer, David L.

    2010-01-01

    Hormones are chemical messengers that regulate many life functions. Deviations from normal hormone levels can have serious health consequences. Accurate measurement of hormone levels in serum can be beneficial in diagnosing, monitoring, and treating a number of diseases. Two steroid hormones, cortisol and progesterone, were selected by the Organic Analysis Working Group (OAWG) to evaluate its member Institutes' measurement capabilities for this important class of measurand. Serum concentrations of cortisol range from 30 ng/mL to 230 ng/mL. Serum concentrations of progesterone in adult females range from 0.15 ng/mL to 25 ng/mL but can rise to approx230 ng/mL during pregnancy. The ability to measure cortisol is indicative of a laboratory's ability to measure steroid hormones at concentration levels similar to cortisol. The ability to measure progesterone is indicative of a laboratory's ability to measure steroid hormones with similar functional groups and concentration levels, such as testosterone. Pilot studies CCQM-P77.a and CCQM-P77.b on the determination of cortisol and progesterone in human serum were completed in 2006. There was good agreement among the results reported by participants who used isotope dilution/mass spectrometry (ID/MS) with either gas chromatography (GC) or liquid chromatography (LC). In 2007 the OAWG decided to proceed with key comparison (KC) CCQM-K63.a, cortisol in human serum, and CCQM-K63.b, progesterone in human serum. Thus, following established OAWG procedure, only results from participants that (1) used an ID/MS-based method, (2) participated in the relevant pilot study, and (3) used a metrologically traceable primary standard were to be eligible for use in calculating the key comparison reference value (KCRV) for each measurand. Six laboratories participated in CCQM-K63.a and eight laboratories participated in CCQM-K63.b. The same pooled frozen female serum material was used in both of the KCs. The mean value for the six ID/MS-based cortisol results is 100.4 ng/g with a relative standard deviation (%RSD) of 1.1%. The mean value for the seven ID/MS-based progesterone originally reported results is 2.83 with a %RSD of 1.8%. While a number of the reported results were not eligible to be used in establishing the KCRVs, the KCRVs as estimated from just the eligible results agree very well with these means. The excellent among-participant agreement indicates that ID/MS-based measurement procedures can provide precise and true results for steroid hormones at levels greater than about 1 ng/g. The progesterone result reported by a laboratory using a non-isotopically labelled internal standard was about 11% larger than the KCRV. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  10. Effect of Feeding an Iodine-Restricted Diet in Cats with Spontaneous Hyperthyroidism.

    PubMed

    Hui, T Y; Bruyette, D S; Moore, G E; Scott-Moncrieff, J C

    2015-01-01

    Exclusive feeding of an iodine-restricted diet has been proposed as a method for controlling clinical manifestations of hyperthyroidism in hyperthyroid cats. To determine the effect of feeding an iodine-restricted diet on TT4 concentrations and clinical signs in cats with spontaneous hyperthyroidism. Forty-nine client-owned cats with spontaneous hyperthyroidism. Retrospective case series. Hyperthyroid cats were exclusively fed a commercially available iodine-restricted diet. Clinical response was assessed by change in weight and heart rate and serum TT4, blood urea nitrogen (BUN), and creatinine concentrations at various times during dietary management (21-60 days, 60-180 days). Serum TT4 normalized in 20/48 cats (42%) and 39/47 cats (83%) at 21-60 days and 61-180 days, respectively. Cats in which the TT4 concentrations were still above reference range at 21-60 days had a significantly higher starting TT4 than those that normalized their TT4 levels during the same time period (P = .038). Body weight did not significantly increase (P = .34) nor heart rate decrease (P = .64) during the study. There was a significant decrease in serum creatinine (P = .028). Cats in the low reference range for serum TT4 concentrations did not have a significant increase in body weight (P = .41) nor creatinine (P = .54) when compared to those with high reference range. Restricted-iodine diets were effective at maintaining serum TT4 concentrations within reference ranges for a majority of cats with spontaneous hyperthyroidism over 1 year, although not all clinical signs of hyperthyroidism improved. Copyright © 2015 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  11. Reference Ranges for Serum Uric Acid among Healthy Assamese People

    PubMed Central

    Das, Madhumita; Borah, N. C.; Ghose, M.; Choudhury, N.

    2014-01-01

    This study was designed to establish reference ranges for serum uric acid among healthy adult Assamese population. Samples from 1470 aged 35–86 years were used to establish age and sex related reference range by the centile method (central 95 percentile) for serum uric acid level. There were 51% (n = 754) males and 49% (n = 716) females; 75.9% (n = 1115) of them were from urban area and the rest 24.1% (n = 355) were from the rural area. Majority of the population were nonvegetarian (98.6%, n = 1450) and only 1.4% (n = 20) were vegetarian. The mean age, weight, height, and uric acid of the studied group were 53.6 ± 11.3 years, 62.6 ± 10.5 kg, 160 ± 9.4 cm, and 5.5 ± 1.4 mg/dL, respectively. There is a statistically significant difference in the mean value of the abovementioned parameters between male and female. The observed reference range of uric acid in the population is 2.6–8.2 mg/dL which is wider than the current reference range used in the laboratory. Except gender (P < 0.0001), we did not find any significant relation of uric acid with other selected factors. PMID:24672726

  12. The reverse J-shaped association between serum total 25-hydroxyvitamin D and all-cause mortality: the impact of assay standardization

    USDA-ARS?s Scientific Manuscript database

    The impact of standardizing the originally measured serum total 25-hydroxyvitamin D [25(OH)D] values from Third National Health and Nutrition Examination Survey (NHANES III, 1988-1994) on the association between 25(OH)D and rate of all-cause mortality was evaluated. Values were standardized to gold ...

  13. [Hypothyroidism-when and how to treat?

    PubMed

    Koehler, V F; Reincke, M; Spitzweg, C

    2018-06-05

    The diagnosis of hypothyroidism is primarily based on clinical signs and symptoms as well as measurement of thyroid-stimulating hormone (TSH) concentration. Subclinical hypothyroidism is characterized by elevated TSH with normal serum free thyroxine (fT 4 ) and triiodothyronine (fT 3 ) levels, while in manifest hypothyroidism serum fT 4 and fT 3 levels are reduced. Common causes of primary hypothyroidism are autoimmune thyroiditis as well as therapeutic interventions, such as thyroid surgery or radioiodine therapy. Signs and symptoms of hypothyroidism include fatigue, bradycardia, constipation and cold intolerance. In subclinical hypothyroidism, symptoms may be absent. Initiation of levothyroxine (T 4 ) therapy not only depends on the level of TSH elevation, but also on other factors, such as patient age, presence of pregnancy or comorbidities. Treatment of patients with subclinical hypothyroidism is still a controversial topic. In general, thyroid hormone replacement therapy in non-pregnant adults ≤ 70 years is clearly indicated if the TSH concentration is >10 mU/l. Standard of care for treatment of hypothyroidism is T 4 monotherapy. The biochemical treatment goal for T 4 replacement in primary hypothyroidism is a TSH level within the reference range (0.4-4.0 mU/l). In contrast, in secondary hypothyroidism, serum fT 4 levels are the basis for adjusting thyroid hormone dosage. Inadequate replacement of T 4 resulting in subclinical or even manifest hyperthyroidism should urgently be avoided. T 4 /liothyronine (T3) combination therapy is still a matter of debate and not recommended as standard therapy, but may be considered in patients with persistence of symptoms, despite optimal T 4 treatment, based on expert opinion.

  14. Haemodialysis dose and serum bicarbonate (chapter 7).

    PubMed

    Tomson, Charlie; Thomas, David; Rao, Raman; van Schalkwyk, Dirk; Ansell, David

    2007-08-01

    Data from 21 renal units was insufficient to allow analyses of the dose of dialysis in those units. Amongst the remainder, there is evidence of a progressive increase in the proportion of patients meeting the Renal Association audit standard for urea reduction ratio (URR). In the UK as a whole, 81% of prevalent haemodialysis patients met the standard for URR in 2005. Greater achievement of the standard in a given unit is associated with a higher median URR in that unit, although there is some evidence that some units have been able to narrow the distribution of achieved URR values. Achievement of the standard remains, as in previous years' Reports, less common amongst patients recently established on haemodialysis compared with those established on haemodialysis for longer. Correction of acidosis, as measured by serum bicarbonate concentration remains highly variable, although there is continued uncertainty about the interpretation of routine measurements of venous serum bicarbonate concentration in haemodialysis patients. Overall, approximately 64% of UK haemodialysis patients, and 50% of peritoneal dialysis patients met the Renal Association standard for serum bicarbonate in 2005.

  15. Estimating equations for glomerular filtration rate in the era of creatinine standardization: a systematic review.

    PubMed

    Earley, Amy; Miskulin, Dana; Lamb, Edmund J; Levey, Andrew S; Uhlig, Katrin

    2012-06-05

    Clinical laboratories are increasingly reporting estimated glomerular filtration rate (GFR) by using serum creatinine assays traceable to a standard reference material. To review the performance of GFR estimating equations to inform the selection of a single equation by laboratories and the interpretation of estimated GFR by clinicians. A systematic search of MEDLINE, without language restriction, between 1999 and 21 October 2011. Cross-sectional studies in adults that compared the performance of 2 or more creatinine-based GFR estimating equations with a reference GFR measurement. Eligible equations were derived or reexpressed and validated by using creatinine measurements traceable to the standard reference material. Reviewers extracted data on study population characteristics, measured GFR, creatinine assay, and equation performance. Eligible studies compared the MDRD (Modification of Diet in Renal Disease) Study and CKD-EPI (Chronic Kidney Disease Epidemiology Collaboration) equations or modifications thereof. In 12 studies in North America, Europe, and Australia, the CKD-EPI equation performed better at higher GFRs (approximately >60 mL/min per 1.73 m(2)) and the MDRD Study equation performed better at lower GFRs. In 5 of 8 studies in Asia and Africa, the equations were modified to improve their performance by adding a coefficient derived in the local population or removing a coefficient. Methods of GFR measurement and study populations were heterogeneous. Neither the CKD-EPI nor the MDRD Study equation is optimal for all populations and GFR ranges. Using a single equation for reporting requires a tradeoff to optimize performance at either higher or lower GFR ranges. A general practice and public health perspective favors the CKD-EPI equation. Kidney Disease: Improving Global Outcomes.

  16. INDUCTION OF CYTOKINE PRODUCTION IN CHEETAH (ACINONYX JUBATUS) PERIPHERAL BLOOD MONONUCLEAR CELLS AND VALIDATION OF FELINE-SPECIFIC CYTOKINE ASSAYS FOR ANALYSIS OF CHEETAH SERUM.

    PubMed

    Franklin, Ashley D; Crosier, Adrienne E; Vansandt, Lindsey M; Mattson, Elliot; Xiao, Zhengguo

    2015-06-01

    Peripheral blood mononuclear cells (PBMCs) were isolated from the whole blood of cheetahs (Acinonyx jubatus ; n=3) and stimulated with lipopolysaccharides (LPS) to induce the production of proinflammatory cytokines TNF-α, IL-1β, and IL-6 for establishment of cross-reactivity between these cheetah cytokines and feline-specific cytokine antibodies provided in commercially available Feline DuoSet® ELISA kits (R&D Systems, Inc., Minneapolis, Minnesota 55413, USA). This study found that feline-specific cytokine antibodies bind specifically to cheetah proinflammatory cytokines TNF-α, IL-1β, and IL-6 from cell culture supernatants. The assays also revealed that cheetah PBMCs produce a measurable, cell concentration-dependent increase in proinflammatory cytokine production after LPS stimulation. To enable the use of these kits, which are designed for cell culture supernatants for analyzing cytokine concentrations in cheetah serum, percent recovery and parallelism of feline cytokine standards in cheetah serum were also evaluated. Cytokine concentrations in cheetah serum were approximated based on the use of domestic cat standards in the absence of cheetah standard material. In all cases (for cytokines TNF-α, IL-1β, and IL-6), percent recovery increased as the serum sample dilution increased, though percent recovery varied between cytokines at a given dilution factor. A 1:2 dilution of serum resulted in approximately 45, 82, and 7% recovery of TNF-α, IL-1β, and IL-6 standards, respectively. Adequate parallelism was observed across a large range of cytokine concentrations for TNF-α and IL-1β; however, a significant departure from parallelism was observed between the IL-6 standard and the serum samples (P=0.004). Therefore, based on our results, the Feline DuoSet ELISA (R&D Systems, Inc.) kits are valid assays for the measurement of TNF-α and IL-1β in cheetah serum but should not be used for accurate measurement of IL-6.

  17. Study on the interaction of the toxic food additive carmoisine with serum albumins: a microcalorimetric investigation.

    PubMed

    Basu, Anirban; Kumar, Gopinatha Suresh

    2014-05-30

    The interaction of the synthetic azo dye and food colorant carmoisine with human and bovine serum albumins was studied by microcalorimetric techniques. A complete thermodynamic profile of the interaction was obtained from isothermal titration calorimetry studies. The equilibrium constant of the complexation process was of the order of 10(6)M(-1) and the binding stoichiometry was found to be 1:1 with both the serum albumins. The binding was driven by negative standard molar enthalpy and positive standard molar entropy contributions. The binding affinity was lower at higher salt concentrations in both cases but the same was dominated by mostly non-electrostatic forces at all salt concentrations. The polyelectrolytic forces contributed only 5-8% of the total standard molar Gibbs energy change. The standard molar enthalpy change enhanced whereas the standard molar entropic contribution decreased with rise in temperature but they compensated each other to keep the standard molar Gibbs energy change almost invariant. The negative standard molar heat capacity values suggested the involvement of a significant hydrophobic contribution in the complexation process. Besides, enthalpy-entropy compensation phenomenon was also observed in both the systems. The thermal stability of the serum proteins was found to be remarkably enhanced on binding to carmoisine. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. A pilot study on the effect of Catha edulis Frosk., (Celastraceae) on metabolic syndrome in WOKW rats.

    PubMed

    Mahmood, Samira Abdulla; Lindequist, Ulrike

    2008-04-10

    This study investigated the effect of Catha edulis (khat) on some important parameters of the metabolic syndrome in Wistar Ottawa Karlsburg W (WOKW) rat. The animals were fed with the standard chow containing 5% air dried pulverized khat leaves for 14 days; followed by the standard chow for 16 days. The khat leaves were sorted into green (khat light; KL) and crimson (khat dark; KD) leaves. The control rats were fed on standard chow. Blood glucose (G), serum insulin, serum leptin and serum lipids (triglycerides, total cholesterol, HDL-, LDL-, and VLDL cholesterol) were determined. Feeding with khat leaves reduced the body weight and the triglyceride level of the animals. The effect of KD on these parameters was stronger than that of KL. KD lowered the blood glucose concentration and the leptin content whereas KL was inactive. The khat intake had no significant influence on serum insulin, total serum cholesterol, HDL-, LDL- and VLDL-cholesterol.

  19. Blood serum chemistry of wild Alaskan Black-capped Chickadees (Poecile atricapillus) with avian keratin disorder

    USGS Publications Warehouse

    Van Hemert, Caroline R.; Handel, Colleen M.

    2016-01-01

    We measured serum chemistries in wild Black-capped Chickadees (Poecile atricapillus) from Alaska to test for potential differences associated with beak deformities characteristic of avian keratin disorder. Lower uric acid in affected birds was the only difference detected between groups, although sample sizes were small. This difference could be associated with fasting or malnutrition in birds with beak deformities, but it is challenging to interpret its biologic significance without reference values. Black-capped Chickadees had high levels of aspartate aminotransferase, lactate dehydrogenase, and creatine kinase relative to reference values for companion birds. However, all serum chemistry parameters from our study were within the range of values reported from other apparently healthy wild-caught birds.

  20. Re-recognition of Age-dependent Reference Range for the Serum Creatinine Level in Teenagers - A Case of Slowly Progressive Tubulointerstitial Nephritis which Occurred in an Adolescent.

    PubMed

    Ono, Hiroyuki; Nagai, Kojiro; Shibata, Eriko; Matsuura, Motokazu; Kishi, Seiji; Inagaki, Taizo; Minato, Masanori; Yoshimoto, Sakiya; Ueda, Sayo; Obata, Fumiaki; Nishimura, Kenji; Tamaki, Masanori; Kishi, Fumi; Murakami, Taichi; Abe, Hideharu; Kinoshita, Yukiko; Urushihara, Maki; Kagami, Shoji; Doi, Toshio

    2017-08-15

    For the first time, a 15-year-old boy was found to have a slight degree of proteinuria and microscopic hematuria during annual school urinalysis screening. His kidney function had already severely deteriorated. A kidney biopsy revealed tubulointerstitial nephritis (TIN) with diffuse inflammatory cell infiltration. His medical records showed his serum creatinine level to be 0.98 mg/dL two years ago, which was abnormally high considering his age. Although the etiology of slowly progressive TIN was unclear, glucocorticoid and immunosuppressant therapy improved his kidney function. This case report suggests that all doctors should recognize the reference range for the serum creatinine level in teenagers.

  1. Re-recognition of Age-dependent Reference Range for the Serum Creatinine Level in Teenagers - A Case of Slowly Progressive Tubulointerstitial Nephritis which Occurred in an Adolescent -

    PubMed Central

    Ono, Hiroyuki; Nagai, Kojiro; Shibata, Eriko; Matsuura, Motokazu; Kishi, Seiji; Inagaki, Taizo; Minato, Masanori; Yoshimoto, Sakiya; Ueda, Sayo; Obata, Fumiaki; Nishimura, Kenji; Tamaki, Masanori; Kishi, Fumi; Murakami, Taichi; Abe, Hideharu; Kinoshita, Yukiko; Urushihara, Maki; Kagami, Shoji; Doi, Toshio

    2017-01-01

    For the first time, a 15-year-old boy was found to have a slight degree of proteinuria and microscopic hematuria during annual school urinalysis screening. His kidney function had already severely deteriorated. A kidney biopsy revealed tubulointerstitial nephritis (TIN) with diffuse inflammatory cell infiltration. His medical records showed his serum creatinine level to be 0.98 mg/dL two years ago, which was abnormally high considering his age. Although the etiology of slowly progressive TIN was unclear, glucocorticoid and immunosuppressant therapy improved his kidney function. This case report suggests that all doctors should recognize the reference range for the serum creatinine level in teenagers. PMID:28781321

  2. Measurement of glomerular filtration rate in the conscious rat.

    PubMed

    Pestel, Sabine; Krzykalla, Volker; Weckesser, Gerhard

    2007-01-01

    Glomerular filtration rate (GFR) is an important parameter for studying drug-induced impairments on renal function in rats. The GFR is calculated from the concentration of creatinine and blood urea nitrogen (BUN) in serum and in urine, respectively. Following current protocols serum and urine samples must be taken from the same animal. Thus, in order to determine time-dependent effects it is necessary to use for each time point one separated group of animals. We developed a statistical test which allows analyzing the GFR from two different groups of animals: one used for repeated serum and the other one used for repeated urine analysis. Serum and urine samples were taken from two different sets of rats which were otherwise treated identically, i.e. drug doses, routes of administration (per os or per inhalation) and tap water loading. For each dose group GFR mean, standard deviation and statistical analysis to identify differences between the dose groups were determined. After determination of the optimal time points for measurements, the effect on GFR of the three reference compounds, furosemide, hydrochlorothiazide and formoterol, was calculated. The results showed that the diuretic drugs furosemide and hydrochlorothiazide decreased the GFR and the antidiuretic drug formoterol increased the GFR, as counter regulation on urine loss or urine retention, respectively. A mathematical model and the corresponding algorithm were developed, which can be used to calculate the GFR, and to test for differences between groups from two separated sets of rats, one used for urine, and the other one for serum analysis. This new method has the potential to reduce the number of animals needed and to improve the quality of data generated from various groups of animals in renal function studies.

  3. Effect of Fluid Intake on Hydration Status and Skin Barrier Characteristics in Geriatric Patients: An Explorative Study.

    PubMed

    Akdeniz, Merve; Boeing, Heiner; Müller-Werdan, Ursula; Aykac, Volkan; Steffen, Annika; Schell, Mareike; Blume-Peytavi, Ulrike; Kottner, Jan

    2018-01-01

    Inadequate fluid intake is assumed to be a trigger of water-loss dehydration, which is a major health risk in aged and geriatric populations. Thus, there is a need to search for easy to use diagnostic tests to identify dehydration. Our overall aim was to investigate whether skin barrier parameters could be used for predicting fluid intake and/or hydration status in geriatric patients. An explorative observational comparative study was conducted in a geriatric hospital including patients aged 65 years and older. We measured 3-day fluid intake, skin barrier parameters, Overall Dry Skin Score, serum osmolality, cognitive and functional health, and medications. Forty patients were included (mean age 78.45 years and 65% women) with a mean fluid intake of 1,747 mL/day. 20% of the patients were dehydrated and 22.5% had an impending dehydration according to serum osmolality. Multivariate analysis suggested that skin surface pH and epidermal hydration at the face were associated with fluid intake. Serum osmolality was associated with epidermal hydration at the leg and skin surface pH at the face. Fluid intake was not correlated with serum osmolality. Diuretics were associated with high serum osmolality. Approximately half of the patients were diagnosed as being dehydrated according to osmolality, which is the current reference standard. However, there was no association with fluid intake, questioning the clinical relevance of this measure. Results indicate that single skin barrier parameters are poor markers for fluid intake or osmolality. Epidermal hydration might play a role but most probably in combination with other tests. © 2018 S. Karger AG, Basel.

  4. Measurement of titanium in hip-replacement patients by inductively coupled plasma optical emission spectroscopy.

    PubMed

    Harrington, Chris F; McKibbin, Craig; Rahanu, Monika; Langton, David; Taylor, Andrew

    2017-05-01

    Background Patients with metal-on-metal hip replacements require testing for cobalt and chromium. There may also be a need to test for titanium, which is used in the construction of the femoral stem in total hip replacements. It is not possible to use quadrupole inductively coupled plasma mass spectrometry due to interferences. Methods Titanium was measured using inductively coupled plasma optical emission spectroscopy using the emission line at 336.1 nm and Y (internal standard) at 371.0 nm. Internal quality control materials were prepared for blood and serum and concentrations assigned using a sector field-inductively coupled plasma mass spectrometer. A candidate whole blood certified reference material was also evaluated. Results The method had detection and quantitation limits of 0.6 and 1.9 µg/L, respectively. The respective bias (%) and measurement uncertainty ( U) (k = 2) were 3.3% and 2.0 µg/L (serum) and - 1.0% and 1.4 µg/L (whole blood). The respective repeatability and intermediate precision (%) were 5.1% and 10.9% (serum) and 2.4% and 8.6% (whole blood). The concentration of titanium was determined in patients' samples, serum (median = 2.4 µg/L, n = 897) and whole blood (median = 2.4 µg/L, n = 189). Serum is recommended for monitoring titanium in patients, since the concentration is higher than in whole blood and the matrix less problematic. In hip fluid samples, the concentrations were much higher (mean 58.5 µg/L, median 5.1 µg/L, n = 83). Conclusions A method based on inductively coupled plasma optical emission spectroscopy was developed and validated for measuring titanium in clinical samples.

  5. Studies on the analysis of 25-hydroxyvitamin D{sub 3} by isotope-dilution liquid chromatography–tandem mass spectrometry using enzyme-assisted derivatisation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abdel-Khalik, Jonas, E-mail: J.A.F.A.ABDEL-KHALIK.744116@swansea.ac.uk; Crick, Peter J.; Carter, Graham D.

    2014-04-11

    Highlights: • New method for the analysis of 25-hydroxyvitamin D{sub 3} exploiting Girard P derivatisation. • Method also applicable to vitamin D{sub 3}, 1α,25- and 24,25-dihydroxyvitamin D{sub 3}. • By modification of the method 3-epi-25-hydroxyvitamin D{sub 3} can also be analysed. - Abstract: The total serum concentration of 25-hydroxyvitamins D (25-hydroxyvitamin D{sub 3} and 25-hydroxyvitamin D{sub 2}) is currently used as an indicator of vitamins D status. Vitamins D insufficiency is claimed to be associated with multiple diseases, thus accurate and precise reference methods for the quantification of 25-hydroxyvitamins D are needed. Here we present a novel enzyme-assisted derivatisation methodmore » for the analysis of vitamins D metabolites in adult serum utilising 25-[26,26,26,27,27,27-{sup 2}H{sub 6}]hydroxyvitamin D{sub 3} as the internal standard. Extraction of 25-hydroxyvitamins D from serum is performed with acetonitrile, which is shown to be more efficient than ethanol. Cholesterol oxidase is used to oxidize the 3β-hydroxy group in the vitamins D metabolites followed by derivatisation of the newly formed 3-oxo group with Girard P reagent. 17β-Hydroxysteroid dehydrogenase type 10 is shown to oxidize selectively the 3α-hydroxy group in the 3α-hydroxy epimer of 25-hydroxyvitamin D{sub 3}. Quantification is achieved by isotope-dilution liquid chromatography–tandem mass spectrometry. Recovery experiments for 25-hydroxyvitamin D{sub 3} performed on adult human serum give recovery of 102–106%. Furthermore in addition to 25-hydroxyvitamin D{sub 3}, 24,25-dihydroxyvitamin D{sub 3} and other uncharacterised dihydroxy metabolites, were detected in adult human serum.« less

  6. Comparison of the use of scapular ultrasonography, physical examination, and measurement of serum biomarkers of bone turnover versus scintigraphy for detection of bone fragility syndrome in horses.

    PubMed

    Arens, Amanda M; Puchalski, Sarah M; Whitcomb, Mary Beth; Bell, Robin; Gardner, Ian A; Stover, Susan M

    2013-01-01

    To define scintigraphic, physical examination, and scapular ultrasonographic findings consistent with bone fragility syndrome (BFS) in horses; develop indices of BFS severity; and assess accuracy of physical examination, scapular ultrasonography, and serum biomarkers for BFS diagnosis. Prospective case-control study. 48 horses (20 horses with BFS and 28 control horses). Horses underwent forelimb scintigraphic evaluation, physical examination, scapular ultrasonography, and serum collection. Scintigraphy was used as a reference standard to which physical examination, scapular ultrasonography, and concentrations of serum biomarkers (carboxy-terminal telopeptide of collagen crosslinks and bone-specific alkaline phosphatase activity) were compared for assessing accuracy in BFS diagnosis. A diagnosis of BFS was strongly supported on scintigraphy by ≥ 2 regions of increased radiopharmaceutical uptake, including 1 region in the scapular spine and 1 region in the scapular body or ribs; on physical examination by lateral bowing of the scapulae; and on ultrasonography by widening of the scapular spine. None of the tests evaluated were accurate enough to replace scintigraphy for mild disease; however, physical examination and scapular ultrasonography were accurate in horses with moderate to severe BFS. Serum biomarkers were not accurate for BFS diagnosis. Scintigraphy remained the most informative diagnostic modality for BFS, providing insight into disease severity and distribution; however, physical examination and scapular ultrasonographic abnormalities were diagnostic in horses with moderate to severe disease. Proposed severity indices classified the spectrum of disease manifestations. Clearly defined criteria for interpretation of diagnostic tests aid in the detection of BFS. Severity indices may be useful for assessing disease progression and response to treatment.

  7. Evaluation and reporting of enzyme immunoassay determinations of antibody to herpes simplex virus in sera and cerebrospinal fluid.

    PubMed Central

    Cremer, N E; Cossen, C K; Hanson, C V; Shell, G R

    1982-01-01

    Several methods for evaluating and reporting enzyme immunoassay (EIA) determinations of antibody to herpes simplex virus derived from one dilution of single serum samples were studied. An EIA ratio method for serological evidence of current infection from paired serum samples was also evaluated. Optical density (OD) of the reaction at a 1:100 serum dilution and estimated titers obtained by reference of the OD of the serum dilution to a standard curve were compared to the corresponding plotted EIA titer obtained by titration to endpoint. Neither the OD per se nor the estimated titer was completely predictive of the plotted titer (correlation coefficient [r] of 0.824 and 0.817, respectively), and they provided only a semiquantitative measurement of antibody concentration. For an antibody status report, however, OD would be sufficient if related to the cutoff value as an EIA index (OD of sample divided by cutoff OD for positive specimens). The OD of the EIA reaction at a single dilution (1:5) of cerebrospinal fluid, on the other hand, correlated quite well with the titer obtained by titration (r = 0.950). For serological diagnosis of current infection, the OD ratio of convalescence-phase/acute-phase sera was determined at several dilutions. A ratio of greater than or equal to 1.54 was calculated as a reliable index for a significant rise in antibody concentration and compatible with current infection. By determining the convalescent-phase/acute-phase serum ratio at two dilutions, 1:100 and 1:1,000, the EIA ratio method appeared to be a sensitive as or more sensitive than, complement fixation in diagnosing current infection. PMID:6284791

  8. Effect of delayed serum separation and storage temperature on serum glucose concentration in horse, dog, alpaca, and sturgeon.

    PubMed

    Collicutt, Nancy B; Garner, Bridget; Berghaus, Roy D; Camus, Melinda S; Hart, Kelsey

    2015-03-01

    Although delays between blood sample collection and analysis are common in veterinary medicine, the effect of prolonged serum-clot contact time on serum glucose concentration is not well established and species differences have not been elucidated. The objective was to investigate the effect of storage time and temperature on serum glucose concentration in stored whole blood samples from horse, dog, alpaca, and sturgeon. Whole blood specimens were divided into 7 no-additive tubes and serum was separated from one sample within one hour, serving as the reference sample. The remaining samples were stored at 4°C and 25°C, then centrifuged and serum glucose measured by automated analysis at 2, 4, and 8 hours postcollection. Glucose concentrations were compared using linear mixed models. The decline in serum glucose concentration for all samples stored at 4°C was not statistically significant, except for the 8-hour samples from sturgeon and dog. At 25°C, serum glucose concentration was comparable to reference values at 2 hours in sturgeon and alpaca, but significantly lower at 4 and 8 hours in those species, and at all time points in equine and canine specimens, being most prominent after 8 hours of storage in canine specimens. Storage at 4°C limits serum glucose decline for at least 4 hours in all species tested and up to 8 hours in specimens of horse and alpaca. At 25°C, serum-clot contact time should not exceed 1 hour in equine and canine samples, and 2 hours in specimens from alpaca and sturgeon. © 2014 American Society for Veterinary Clinical Pathology.

  9. Racial difference in serum Vitamin B/sub 12/ levels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kwee, H.G.; Bowman, H.S.; Wells, L.W.

    1985-07-01

    Measurements of the serum Vitamin B/sub 12/ concentrations of 49 black and 49 white healthy adults demonstrate a significantly higher mean serum Vitamin B/sub 12/ level in blacks when compared to whites. The reason for this difference appears to be genetic, although environmental factors may also be involved. It is suggested that clinical laboratories should establish their own separate reference values of serum Vitamin B/sub 12/ for blacks and whites in order to prevent misinterpretation of test results.

  10. Pediatric reference value distributions and covariate-stratified reference intervals for 29 endocrine and special chemistry biomarkers on the Beckman Coulter Immunoassay Systems: a CALIPER study of healthy community children.

    PubMed

    Karbasy, Kimiya; Lin, Danny C C; Stoianov, Alexandra; Chan, Man Khun; Bevilacqua, Victoria; Chen, Yunqi; Adeli, Khosrow

    2016-04-01

    The CALIPER program is a national research initiative aimed at closing the gaps in pediatric reference intervals. CALIPER previously reported reference intervals for endocrine and special chemistry markers on Abbott immunoassays. We now report new pediatric reference intervals for immunoassays on the Beckman Coulter Immunoassay Systems and assess platform-specific differences in reference values. A total of 711 healthy children and adolescents from birth to <19 years of age were recruited from the community. Serum samples were collected for measurement of 29 biomarkers on the Beckman Coulter Immunoassay Systems. Statistically relevant age and/or gender-based partitions were determined, outliers removed, and reference intervals calculated in accordance with Clinical and Laboratory Standards Institute (CLSI) EP28-A3c guidelines. Complex profiles were observed for all 29 analytes, necessitating unique age and/or sex-specific partitions. Overall, changes in analyte concentrations observed over the course of development were similar to trends previously reported, and are consistent with biochemical and physiological changes that occur during childhood. Marked differences were observed for some assays including progesterone, luteinizing hormone and follicle-stimulating hormone where reference intervals were higher than those reported on Abbott immunoassays and parathyroid hormone where intervals were lower. This study highlights the importance of determining reference intervals specific for each analytical platform. The CALIPER Pediatric Reference Interval database will enable accurate diagnosis and laboratory assessment of children monitored by Beckman Coulter Immunoassay Systems in health care institutions worldwide. These reference intervals must however be validated by individual labs for the local pediatric population as recommended by CLSI.

  11. Establishment of reference values in a healthy population and interpretation of serum PTH concentrations in hemodialyzed patients according to the KDIGO Guidelines using the Lumipulse® G whole PTH (3rd generation) assay.

    PubMed

    Cavalier, Etienne; Salsé, Margot; Dupuy, Anne-Marie; Bargnoux, Anne-Sophie; Watar, Florence; Souberbielle, Jean-Claude; Delanaye, Pierre; Cristol, Jean-Paul

    2018-04-01

    3rd generation PTH assays only detect the bioactive 1-84 fragment. Since standardization is still lacking, each new PTH assay requires to establish reference values and to assess the impact in the medical care of the mineral and bone disorders in hemodialyzed patients. Using Fujirebio Lumipulse G wPTH assay, serum PTH levels were measured in a population of 439 healthy subjects from France and Belgium PTH levels were also determined in 119 hemodialyzed patients. These patients were classified according to the KDIGO recommendation. Reference range was found to be 6.5 (90%CI: 6.0-7.0) - 41.8 (90% CI: 38.1-43.7). In hemodialysis patients, Passing-Bablock regression between 3rd generation PTH from Fujirebio and DiaSorin was DiaSorin = 1.01 xFujirebio-2.4 with a slope not different from 1.0(95%CI: 0.96-1.04) and a non-significant intercept, ranging from -6.0 to 0.1. Hemodialysis patients with a PTH concentration below 2-fold the Upper Limit of Normality (ULN), within the KDIGO range and upper 9-fold upper limit were respectively 33.6%, 54.6%, 11.8% (Fujirebio Lumipulse) and 36.1%, 51.3% and 12.6% (Diasorin Liaison). We determined a reference range with the 3rd generation PTH assay from Fujirebio. In a hemodialysis population, 3rd generation assays from Fujirebio and DiaSorin provide similar results. To the best of our knowledge, this is the first time that we can show similar PTH results obtained by 2 different 3rd generation PTH assays in healthy subjects and hemodialyzed patients without mathematically processing them. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  12. Acetaminophen in serum and plasma estimated by high-pressure liquid chromatography: a micro-scale method.

    PubMed

    Blair, D; Rumack, B H

    1977-01-01

    We describe a capillary-sampling method for serum or plasma acetaminophen by cation-exchange chromatography. As little as 1.5 mul of plasma or serum and an equal volume of the internal standard (N-butyryl-p-aminophenol) were run, with a precision of +/- 5% between duplicates. Acetaminophen and the internal standard chromatographed in 32 and 50 min, respectively, distinct from intrinsic plasma peaks and peaks caused by other medications.

  13. An assessment of 25-hydroxyvitamin D measurements in comparability studies conducted by the Vitamin D Metabolites Quality Assurance Program.

    PubMed

    Bedner, Mary; Lippa, Katrice A; Tai, Susan S-C

    2013-11-15

    The National Institute of Standards and Technology (NIST), in collaboration with the National Institutes of Health Office of Dietary Supplements, established the first accuracy-based program for improving the comparability of vitamin D metabolite measurements, the Vitamin D Metabolites Quality Assurance Program. The study samples were human serum or plasma Standard Reference Materials (SRMs) with 25-hydroxyvitamin D values that were determined at NIST. Participants evaluated the materials using immunoassay (IA), liquid chromatography (LC) with mass spectrometric detection, and LC with ultraviolet absorbance detection. NIST evaluated the results for concordance within the participant community as well as trueness relative to the NIST value. For the study materials that contain mostly 25-hydroxyvitamin D3 (25(OH)D3),the coefficient of variation (CV) for the participant results was consistently in the range from 7% to 19%, and the median values were biased high relative to the NIST values. However, for materials that contain significant concentrations of both 25-hydroxyvitamin D2 (25(OH)D2) and 25(OH)D3, the median IA results were biased lower than both the LC and the NIST values, and the CV was as high as 28%. The first interlaboratory comparison results for SRM 972a Vitamin D Metabolites in Human Serum are also reported. Relatively large within-lab and between-lab variability hinders conclusive assessments of bias and accuracy. © 2013.

  14. Validity of the International Classification of Diseases, Tenth Revision code for acute kidney injury in elderly patients at presentation to the emergency department and at hospital admission

    PubMed Central

    Hwang, Y Joseph; Shariff, Salimah Z; Gandhi, Sonja; Wald, Ron; Clark, Edward; Fleet, Jamie L; Garg, Amit X

    2012-01-01

    Objective To evaluate the validity of the International Classification of Diseases, Tenth Revision (ICD-10) code N17x for acute kidney injury (AKI) in elderly patients in two settings: at presentation to the emergency department and at hospital admission. Design A population-based retrospective validation study. Setting Southwestern Ontario, Canada, from 2003 to 2010. Participants Elderly patients with serum creatinine measurements at presentation to the emergency department (n=36 049) or hospital admission (n=38 566). The baseline serum creatinine measurement was a median of 102 and 39 days prior to presentation to the emergency department and hospital admission, respectively. Main outcome measures Sensitivity, specificity and positive and negative predictive values of ICD-10 diagnostic coding algorithms for AKI using a reference standard based on changes in serum creatinine from the baseline value. Median changes in serum creatinine of patients who were code positive and code negative for AKI. Results The sensitivity of the best-performing coding algorithm for AKI (defined as a ≥2-fold increase in serum creatinine concentration) was 37.4% (95% CI 32.1% to 43.1%) at presentation to the emergency department and 61.6% (95% CI 57.5% to 65.5%) at hospital admission. The specificity was greater than 95% in both settings. In patients who were code positive for AKI, the median (IQR) increase in serum creatinine from the baseline was 133 (62 to 288) µmol/l at presentation to the emergency department and 98 (43 to 200) µmol/l at hospital admission. In those who were code negative, the increase in serum creatinine was 2 (−8 to 14) and 6 (−4 to 20) µmol/l, respectively. Conclusions The presence or absence of ICD-10 code N17× differentiates two groups of patients with distinct changes in serum creatinine at the time of a hospital encounter. However, the code underestimates the true incidence of AKI due to a limited sensitivity. PMID:23204077

  15. Age-Specific Normal Reference Range for Serum Anti-Müllerian Hormone in Healthy Chinese Han Women: A nationwide Population-Based Study.

    PubMed

    Du, Xiaofang; Ding, Ting; Zhang, Hanwang; Zhang, Cuilian; Ma, Wenmin; Zhong, Ying; Qu, Wenyu; Zheng, Jie; Liu, Yi; Li, Zhiying; Huang, Kecheng; Deng, Song; Ma, Lanfang; Yang, Jun; Jiang, Jingjing; Yang, Shuhong; Huang, Jia; Wu, Meng; Fang, Li; Lu, Yunping; Luo, Aiyue; Wang, Shixuan

    2016-08-01

    The increasing use of anti-Müllerian hormone (AMH) in clinic has raised concerns regarding the reliable reference range for this test. However, the reference range for AMH in normal Chinese female population has not been established. Furthermore, relationship between AMH and other clinical markers such as body mass index (BMI) and antral follicle counts (AFCs) and other sex-related hormones have not been examined in normal population-based women. We aimed to determine the age-specific reference range for serum AMH in healthy Chinese women throughout reproductive age to menopause and to estimate relationship between AMH and other clinical markers in healthy women. In this multicenter and nationwide study, advertisements were used to recruit 2055 women, aged 20 to 55 years, from 6 different regions in China; 1590 (77.37%) women met the inclusion criteria for the reference range population. We measured the baseline serum AMH levels using new Beckman Coulter Gen II assay. Serum concentration of follicle-stimulating hormone (FSH), luteinizing hormone (LH), estradiol (E2), testosterone (T), prolactin (PRL), progesterone (PRG), and AFCs were also determined in the follicular phase. The AMH-Age nomogram and AMH levels of different age-groups and the relationship between AMH and other clinical markers. Serum AMH concentrations declined progressively with age. A quadratic model defined as log (AMH) = (-1.970 + 0.296 × Age - 0.006 × Age(2)) fitted best the decline of AMH with age. The median AMH levels were 6.23, 5.65, 4.55, 3.74, 2.78, and 1.09 ng/mL for the 20 ≤ age < 25, 25 ≤ age < 30, 30 ≤ age < 33, 33 ≤ age < 37, 37 ≤ age < 40, and 40 ≤ age < 55 groups, respectively. The 5th to 95th percentiles of the AMH levels, as the reference range, were 2.06 to 12.66, 1.77 to 13.83, 1.48 to 11.45, 0.87 to 9.76, 0.56 to 9.49, and 0.08 to 5.70 ng/mL for each age-group. The AMH levels were positively correlated with AFCs and T, LH, PRL and PRG levels and negatively correlated with BMI and FSH levels and were not significantly correlated with E2 levels. The relationship between AMH and other variables remain unchanged except for PRL, which was not significantly correlated with AMH levels after controlling for both age and BMI. This study determined the normal reference ranges for serum AMH levels in a large population-based sample of healthy Chinese women. © The Author(s) 2016.

  16. Biochemical and hematologic reference values for free-ranging, chemically immobilized wild norwegian reindeer (rangifer tarandus tarandus) during early winter.

    PubMed

    Miller, Andrea L; Evans, Alina L; Os, Øystein; Arnemo, Jon M

    2013-04-01

    Hematologic and serum biochemistry values were evaluated in free-ranging, wild Norwegian reindeer (Rangifer tarandus tarandus) as part of a reintroduction program in southwestern Norway in November 1995 and 1996. Animals were immobilized with medetomidine-ketamine by dart from a helicopter. Blood was drawn for serum chemistry from 31 adults (nine males and 22 females) and for hematology from 29 adults (eight males and 21 females). Significant differences (P<0.05) were found between male and female results for alkaline phosphatase, selenium, and zinc. Although there was a significant difference between male and female gamma-globulin values and the total albumin:globulin ratio, the overall values are much lower than those reported for other Rangifer species. Sexual differences should be interpreted with caution due to the low number of males compared to females. References ranges are presented combining male and female results for hematology and serum chemistry and separately for males and females for serum electrophoresis. No correlation was found between induction time and aspartate transaminase, creatine kinase, glucose, cortisol, or total protein. Blood values were generally similar to those published for semidomestic reindeer (Rangifer tarandus tarandus) and free-ranging caribou (Rangifer tarandus caribou), but the effect of capture drugs, stress, season, and sample size should be considered with interpretation. This paper provides the first report of baseline hematologic and serum biochemistry reference ranges for free-ranging, wild Norwegian reindeer during early winter.

  17. Multicentre physiological reference intervals for serum concentrations of immunoglobulins A, G and M, complement C3c and C4 measured with Tina-Quant reagents systems.

    PubMed

    Fuentes-Arderiu, Xavier; Alonso-Gregorio, Eduardo; Alvarez-Funes, Virtudes; Ambrós-Marigómez, Carmen; Coca-Fábregas, Lluís; Cruz-Placer, Marta; Díaz-Fernández, Julián; Pinel-Julián, María Pilar; Gutiérrez-Cecchini, Beatriz; Herrero-Bernal, Pilar; Sempere-Alcocer, Marcos; García-Caballero, Francisca; Del Mar Larrea-Ortiz-Quintana, María; La-Torre-Marcellán, Pedro; Del Señor López-Vélez, María; Mar-Medina, Carmen; Martín-Oncina, Javier; Rodríguez-Hernández, María Victoria; Romero-Sotomayor, María Victoria; Serrano-López, Cándido; Sicilia-Enríquez-de-Salamanca, Adolfo; Velasco-Romero, Ana María; Juvé-Cuxart, Santiago

    2007-01-01

    Clinical laboratories seeking accreditation for compliance with ISO 15189:2003 need to demonstrate that the physiological reference intervals communicated to all users of the laboratory service are appropriate for the patient population served and for the measurement systems used. In the case of immunological quantities, few articles have been published in peer-reviewed journals. A total of 21 clinical laboratories in different regions of Spain collaborated in identifying reference individuals and determining adult reference intervals for some immunological quantities measured using RD/Hitachi Modular Analytics analysers and Tina-Quant reagent systems. These immunological quantities are the mass concentrations of immunoglobulin A, immunoglobulin G, immunoglobulin M, complement C3c and complement C4 in serum. All the logistic work was carried out in co-operation with the supplier of the reagents and analysers (Roche Diagnostics España, S.L., Sant Cugat del Vallès, Catalonia, Spain). From the set of reference values obtained by each laboratory, multicentre reference limits were estimated non-parametrically. The reference intervals estimated in this study for concentrations of serum components under consideration are: complement C3c, 0.62-1.64 g/L for women and men; complement C4, 0.14-0.72 g/L for women and men; immunoglobulin A, 0.89-4.80 g/L for women and men; immunoglobulin G, 6.5-14.3 g/L for women and men; and immunoglobulin M, 0.48-3.38 g/L for women and 0.41-2.46 g/L for men.

  18. Reference Intervals of Alpha-Fetoprotein and Carcinoembryonic Antigen in the Apparently Healthy Population.

    PubMed

    Zhang, Gao-Ming; Guo, Xu-Xiao; Ma, Xiao-Bo; Zhang, Guo-Ming

    2016-12-12

    BACKGROUND The aim of this study was to calculate 95% reference intervals and double-sided limits of serum alpha-fetoprotein (AFP) and carcinoembryonic antigen (CEA) according to the CLSI EP28-A3 guideline. MATERIAL AND METHODS Serum AFP and CEA values were measured in samples from 26 000 healthy subjects in the Shuyang area receiving general health checkups. The 95% reference intervals and upper limits were calculated by using MedCalc. RESULTS We provided continuous reference intervals from 20 years old to 90 years old for AFP and CEA. The reference intervals were: AFP, 1.31-7.89 ng/ml (males) and 1.01-7.10 ng/ml (females); CEA, 0.51-4.86 ng/ml (males) and 0.35-3.45ng/ml (females). AFP and CEA were significantly positively correlated with age in both males (r=0.196 and r=0.198) and females (r=0.121 and r=0.197). CONCLUSIONS Different races or populations and different detection systems may result in different reference intervals for AFP and CEA. Continuous reference intervals of age changes are more accurate than age groups.

  19. Reference intervals for serum reactive oxygen metabolites, biological antioxidant potential, and oxidative stress index in adult rams.

    PubMed

    Oikonomidis, Ioannis L; Kiosis, Evangelos A; Brozos, Christos N; Kritsepi-Konstantinou, Maria G

    2017-03-01

    OBJECTIVE To establish reference intervals for serum reactive oxygen metabolites (ROMs), biological antioxidant potential (BAP), and oxidative stress index (OSi) in adult rams by use of controlled preanalytic and analytic procedures. ANIMALS 123 healthy 1- to 4-year-old rams of 2 Greek breeds (Chios [n = 62] and Florina [61]). PROCEDURES 4 hours after rams were fed, a blood sample was obtained from each ram, and serum was harvested. Concentrations of ROMs and BAP were measured colorimetrically on a spectrophotometric analyzer. The OSi was calculated as ROMs concentration divided by BAP concentration. Combined and breed-specific reference intervals were calculated by use of nonparametric and robust methods, respectively. Reference intervals were defined as the 2.5th to 97.5th percentiles. RESULTS Reference intervals for ROMs, BAP, and OSi for all rams combined were 65 to 109 Carratelli units, 2,364 to 4,491 μmol/L, and 18.2 to 43.0 Carratelli units/(mmol/L), respectively. Reference intervals of Chios rams for ROMs, BAP, and OSi were 56 to 113 Carratelli units, 2,234 to 4,290 μmol/L, and 12.9 to 38.4 Carratelli units/(mmol/L), respectively. Reference intervals of Florina rams for ROMs, BAP, and OSi were 68 to 111 Carratelli units, 2,337 to 4,363 μmol/L, and 14.1 to 38.1 Carratelli units/(mmol/L), respectively. CONCLUSIONS AND CLINICAL RELEVANCE Reference intervals calculated in this study can be used as a guide for the interpretation of ROMs, BAP, and OSi results in rams and, under appropriate conditions, can be adopted for use by veterinary laboratories.

  20. Serum Beta Hydroxybutyrate Concentrations in Cats with Chronic Kidney Disease, Hyperthyroidism, or Hepatic Lipidosis.

    PubMed

    Gorman, L; Sharkey, L C; Armstrong, P J; Little, K; Rendahl, A

    2016-01-01

    Ketones, including beta hydroxybutyrate (BHB), are produced in conditions of negative energy balance and decreased glucose utilization. Serum BHB concentrations in cats are poorly characterized in diseases other than diabetes mellitus. Serum BHB concentrations will be increased in cats with chronic kidney disease (CKD), hyperthyroidism (HT), or hepatic lipidosis (HL). Twenty-eight client-owned cats with CKD, 34 cats with HT, and 15 cats with HL; 43 healthy cats. Prospective observational study. Serum BHB concentrations were measured at admission in cats with CKD, HT, and HL, for comparison with a reference interval established using healthy cats. Results of dipstick urine ketone measurement, when available, were compared to BHB measurement. Beta hydroxybutyrate was above the reference interval (<0.11 mmol/L) in 6/28 cats (21%) with CKD, 7/34 cats (20%) with HT, and 11/15 cats (73%) with HL, significantly exceeding the expected 2.5% above the reference interval for healthy cats (P < .001 for all groups). Elevations were mild in CKD and HT groups (median BHB 0.1 mmol/L for both groups, 80th percentile 0.12 and 0.11 mmol/L, respectively), but more marked in HL cats (median BHB 0.2 mmol/L, 80th percentile 0.84 mmol/L). None of 11 cats with increased serum BHB concentration having urine dipstick analysis performed within 24 h of sampling for BHB were ketonuric. Increases in serum BHB concentrations occur in cats with CKD, HT, and HL, and might provide an useful index of catabolism. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  1. Association of Serum Thyrotropin with Anthropometric Markers of Obesity in the General Population.

    PubMed

    Tiller, Daniel; Ittermann, Till; Greiser, Karin H; Meisinger, Christa; Agger, Carsten; Hofman, Albert; Thuesen, Betina; Linneberg, Allan; Peeters, Robin; Franco, Oscar; Heier, Margit; Kluttig, Alexander; Werdan, Karl; Stricker, Bruno; Schipf, Sabine; Markus, Marcello; Dörr, Marcus; Völzke, Henry; Haerting, Johannes

    2016-09-01

    Except from associations study with body weight, there are few longitudinal data regarding the association between thyroid function and anthropometric measurements such as waist circumference, waist-to-hip ratio, or waist-to height ratio. This study aimed to investigate the association of thyrotropin (TSH) at baseline with changes in different anthropometric markers between baseline and follow-up in the general population. Data were used from four population-based longitudinal cohort studies and one population-based cross-sectional study. A total of 16,902 (8204 males) subjects aged 20-95 years from the general population were studied. Body mass index, waist circumference, waist-to-hip ratio, and waist-to-height ratio were measured. Multivariable median regression models were calculated adjusting for the following covariates: age, sex, baseline value of the respective anthropometric marker, smoking status, follow-up-time period, and study site. In cross-sectional analyses, serum TSH within the reference range was positively associated with waist circumference (β = 0.94 cm [confidence interval (CI) 0.56-1.32]) and waist-to-height-ratio (β = 0.029 [CI 0.017-0.042]). These associations were also present for the full range of TSH. In the longitudinal analyses, serum TSH at baseline was inversely associated with a five-year change of all considered anthropometric measures within the prior defined study-specific reference range, as well as in the full range of serum TSH. High TSH serum levels were positively associated with current anthropometric markers, even in the study-specific reference ranges. In contrast, high TSH serum levels were associated with decreased anthropometric markers over a time span of approximately five years. Further research is needed to determine possible clinical implications as well as public health consequences of these findings.

  2. Serum free light chain reference values: a critical approach.

    PubMed

    Altinier, Sara; Seguso, Mara; Zaninotto, Martina; Varagnolo, Mariacristina; Adami, Fausto; Angeli, Paolo; Plebani, Mario

    2013-05-01

    The clinical usefulness of serum free light chain (FLC) measurement in the management of patients with plasma cell proliferative disorders has been reported in several papers, and most clinical studies use the reference ranges declared by the manufacturer. The aim of the present study was to evaluate the reproducibility of FLCs immunoassay and to validate the reference range, before introducing it in routine setting. Internal quality control materials and a pool of fresh serum samples were used to evaluate imprecision; 162 fresh sera from healthy blood donors were analyzed to evaluate the reference range for FLCs. In order to verify the κ/λ FLC ratio, 43 sera from patients with polyclonal hypergammaglobulinemia were tested. The FLC immunoassay was performed using a nephelometer with the Freelite reagents. The imprecision studies performed using a serum pool tested with two different lots of reagents showed a mean CV of 16.09% for κFLC and of 16.72% for λFLC. Lower CV%s and different mean values were found by calculating the results from each specific lot separately, while different results were obtained using the control materials provided by the manufacturer. In reference subjects, the 2.5-97.5th percentiles were found to be 4.52-22.33 and 4.84-21.88mg/L for κFLC and λFLC, respectively. The range for κ/λ ratio (0.65-2.36) was validated with the values obtained from subjects with polyclonal hypergammaglobulinemia. In retesting 15 samples from blood donor subjects with a different lot of reagents, mean bias percentages of 17.60 for κFLC and 15.26 for λFLC were obtained. These findings confirm the lot-to-lot variability of the FLC assays also in the measurement of polyclonal light chains, as well as the need to carefully validate the reference values. Published by Elsevier Inc.

  3. Serum chemistry reference values for the common genet (Genetta genetta): variations associated with Leishmania infantum infection.

    PubMed

    Millán, Javier; Chirife, Andrea D; Altet, Laura

    2015-03-01

    The role of wildlife in the epidemiology of leishmaniosis in under debate, and determining whether infection with Leishmania infantum causes illness in wild carnivores is important to determine its potential role as a reservoir. To provide for the first time serum biochemistry reference values for the common genet (Genetta genetta), and to determine variations associated with L. infantum infection. Twenty-five serum biochemistry parameters were determined in 22 wild-caught genets. Blood samples were analyzed for L. infantum DNA by means of real-time polymerase chain reaction (PCR). Two female genets were positive for L. infantum DNA but did not show any external clinical sign upon physical examination. Among other variations in the biochemistry values of these genets, one presented a higher concentration of gamma-globulins and cholesterol, whereas the other genet presented increased creatinine, bilirubin, and chloride levels when compared to uninfected females. Sex-related differences in some parameters were also reported. Infection with L. infantum may sometimes be accompanied by abnormal serum biochemistry in wild carnivores. Clinical disease may occur in L. infantum-infected wild carnivores. This has implications in the epidemiology of leishmaniosis. In addition, the data provided here would also be useful as reference values for researchers or rehabilitators working with the common genet.

  4. [The isolation and evaluation of Aspergillus fumigatus antigens].

    PubMed

    Lirio, V de S; de Assis, C M; Cano, M I; Lacaz, C da S

    1992-01-01

    Antigens from three strains of Aspergillus fumigatus (354, 356, and JIG) and an antiserum against the mixing of these antigens have been produced, and evaluated immunochemically. The antigens were obtained through a modified Coleman & Kaufman technique (culture filtrate concentrated by acetone). Analysis by the immunodiffusion test (ID) against homologous serum has yielded 100% sensitivity (with the studied sera). Concerning heterologous sera we found reactivity with a serum of a patient of candidiasis and another with histoplasmosis. The same result was obtained with a reference antigen in immunodiffusion, showing similar standards of response. Titration of the antiserum by ID and counterimmunoelectrophoresis showed a title of 1:32, and by complement fixation (micro-technique) a title of 1:128. Using immunoelectrophoresis (IEF), the produced antiserum yielded 8 lines of precipitation (5 in the anodic pole and 3 in the cathodic one). In SDS-PAGE at 12.5% the antigen has presented a rather complex electrophoretic profile (26 proteic subunits with a molecular weight ranging from 18 a > 100 kDa). Immunogenicity of the antigen was observed in all fractions of SDS-PAGE when the immunoblotting against the antiserum was carried out.

  5. The Asian project for collaborative derivation of reference intervals: (1) strategy and major results of standardized analytes.

    PubMed

    Ichihara, Kiyoshi; Ceriotti, Ferruccio; Tam, Tran Huu; Sueyoshi, Shigeo; Poon, Priscilla M K; Thong, Mee Ling; Higashiuesato, Yasushi; Wang, Xuejing; Kataoka, Hiromi; Matsubara, Akemi; Shiesh, Shu-Chu; Muliaty, Dewi; Kim, Jeong-Ho; Watanabe, Masakazu; Lam, Christopher W K; Siekmann, Lothar; Lopez, Joseph B; Panteghini, Mauro

    2013-07-01

    A multicenter study conducted in Southeast Asia to derive reference intervals (RIs) for 72 commonly measured analytes (general chemistry, inflammatory markers, hormones, etc.) featured centralized measurement to clearly detect regionality in test results. The results of 31 standardized analytes are reported, with the remaining analytes presented in the next report. The study included 63 clinical laboratories from South Korea, China, Vietnam, Malaysia, Indonesia, and seven areas in Japan. A total of 3541 healthy individuals aged 20-65 years (Japan 2082, others 1459) were recruited mostly from hospital workers using a well-defined common protocol. All serum specimens were transported to Tokyo at -80°C and collectively measured using reagents from four manufacturers. Three-level nested ANOVA was used to quantitate variation (SD) of test results due to region, sex, and age. A ratio of SD for a given factor over residual SD (representing net between-individual variations) (SDR) exceeding 0.3 was considered significant. Traceability of RIs was ensured by recalibration using value-assigned reference materials. RIs were derived parametrically. SDRs for sex and age were significant for 19 and 16 analytes, respectively. Regional difference was significant for 11 analytes, including high density lipoprotein (HDL)-cholesterol and inflammatory markers. However, when the data were limited to those from Japan, regionality was not observed in any of the analytes. Accordingly, RIs were derived with or without partition by sex and region. RIs applicable to a wide area in Asia were established for the majority of analytes with traceability to reference measuring systems, whereas regional partitioning was required for RIs of the other analytes.

  6. Development of an enzyme-linked immunosorbent assay for detection of CDCP1 shed from the cell surface and present in colorectal cancer serum specimens.

    PubMed

    Chen, Yang; Harrington, Brittney S; Lau, Kevin C N; Burke, Lez J; He, Yaowu; Iconomou, Mary; Palmer, James S; Meade, Brian; Lumley, John W; Hooper, John D

    2017-05-30

    CUB domain containing protein 1 (CDCP1) is a transmembrane protein involved in progression of several cancers. When located on the plasma membrane, full-length 135kDa CDCP1 can undergo proteolysis mediated by serine proteases that cleave after two adjacent amino acids (arginine 368 and lysine 369). This releases from the cell surface two 65kDa fragments, collectively termed ShE-CDCP1, that differ by one carboxyl terminal residue. To evaluate the function of CDCP1 and its potential utility as a cancer biomarker, in this study we developed an enzyme-linked immunosorbent assay (ELISA) to reliably and easily measure the concentration of ShE-CDCP1 in biological samples. Using a reference standard we demonstrate that the developed ELISA has a working range of 0.68-26.5ng/ml, and the limit of detection is 0.25ng/ml. It displays high intra-assay (repeatability) and high inter-assay (reproducibility) precision with all coefficients of variation ≤7%. The ELISA also displays high accuracy detecting ShE-CDCP1 levels at ≥94.8% of actual concentration using quality control samples. We employed the ELISA to measure the concentration of ShE-CDCP1 in human serum samples with our results suggesting that levels are significantly higher in serum of colorectal cancer patients compared with serum from individuals with benign conditions (p<0.05). Our data also suggest that colorectal cancer patients with stage II-IV disease have at least 50% higher serum levels of ShE-CDCP1 compared with stage I cases (p<0.05). We conclude that the developed ELISA is a suitable method to quantify ShE-CDCP1 concentration in human serum. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. A New Method with General Diagnostic Utility for the Calculation of Immunoglobulin G Avidity

    PubMed Central

    Korhonen, Maria H.; Brunstein, John; Haario, Heikki; Katnikov, Alexei; Rescaldani, Roberto; Hedman, Klaus

    1999-01-01

    The reference method for immunoglobulin G (IgG) avidity determination includes reagent-consuming serum titration. Aiming at better IgG avidity diagnostics, we applied a logistic model for the reproduction of antibody titration curves. This method was tested with well-characterized serum panels for cytomegalovirus, Epstein-Barr virus, rubella virus, parvovirus B19, and Toxoplasma gondii. This approach for IgG avidity calculation is generally applicable and attains the diagnostic performance of the reference method while being less laborious and twice as cost-effective. PMID:10473525

  8. Combined use of serum HCG and sonography in the diagnosis of ectopic pregnancy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kadar, N.; Taylor, K.J.W.; Rosenfield, A.T.

    1983-09-01

    During an 18 month period, 320 patients were referred with clinical suspicion of an ectopic pregnancy. This study is based on 19 patients with ectopic pregnancy who had both a sonographic examination of the pelvis and determination of serum beta human chorionic gonadotropin (HCG) before surgery. Emphasis is focused on the spectrum of sonographic appearances that may occur in ectopic gestation. These are illustrated, and the sonographic criteria that have been used both for a positive diagnosis and for the exclusion of ectopic pregnancy in the past are analyzed. It is suggested that the accuracy of sonography can be increasedmore » by determining the serum HCG level on the day of the scan and by interpreting the findings with reference to the discriminatory HCG zone.« less

  9. Age specific serum anti-Müllerian hormone levels in 1,298 Korean women with regular menstruation

    PubMed Central

    Yoo, Ji Hee; Cha, Sun Wha; Park, Chan Woo; Yang, Kwang Moon; Song, In Ok; Koong, Mi Kyoung; Kang, Inn Soo

    2011-01-01

    Objective To determine the age specific serum anti-Müllerian hormone (AMH) reference values in Korean women with regular menstruation. Methods Between May, 2010 and January, 2011, the serum AMH levels were evaluated in a total of 1,298 women who have regular menstrual cycles aged between 20 and 50 years. Women were classified into 6 categories by age: 20-31 years, 32-34 years, 35-37 years, 38-40 years, 41-43 years, above 43 years. Measurement of serum AMH was measured by commercial enzyme-linked immunoassay. Results The serum AMH levels correlated negatively with age. The median AMH level of each age group was 4.20 ng/mL, 3.70 ng/mL, 2.60 ng/mL, 1.50 ng/mL, 1.30 ng/mL, and 0.60 ng/mL, respectively. The AMH values in the lower 5th percentile of each age group were 1.19 ng/mL, 0.60 ng/mL, 0.42 ng/mL, 0.27 ng/mL, 0.14 ng/mL, and 0.10 ng/mL, respectively. Conclusion This study determined reference values of serum AMH in Korean women with regular menstruation. These values can be applied to clinical evaluation and treatment of infertile women. PMID:22384425

  10. Hematology and serum clinical chemistry reference intervals for free-ranging Scandinavian gray wolves (Canis lupus).

    PubMed

    Thoresen, Stein I; Arnemo, Jon M; Liberg, Olof

    2009-06-01

    Scandinavian free-ranging wolves (Canis lupus) are endangered, such that laboratory data to assess their health status is increasingly important. Although wolves have been studied for decades, most biological information comes from captive animals. The objective of the present study was to establish reference intervals for 30 clinical chemical and 8 hematologic analytes in Scandinavian free-ranging wolves. All wolves were tracked and chemically immobilized from a helicopter before examination and blood sampling in the winter of 7 consecutive years (1998-2004). Seventy-nine blood samples were collected from 57 gray wolves, including 24 juveniles (24 samples), 17 adult females (25 samples), and 16 adult males (30 samples). Whole blood and serum samples were stored at refrigeration temperature for 1-3 days before hematologic analyses and for 1-5 days before serum biochemical analyses. Reference intervals were calculated as 95% confidence intervals except for juveniles where the minimum and maximum values were used. Significant differences were observed between adult and juvenile wolves for RBC parameters, alkaline phosphatase and amylase activities, and total protein, albumin, gamma-globulins, cholesterol, creatinine, calcium, chloride, magnesium, phosphate, and sodium concentrations. Compared with published reference values for captive wolves, reference intervals for free-ranging wolves reflected exercise activity associated with capture (higher creatine kinase activity, higher glucose concentration), and differences in nutritional status (higher urea concentration).

  11. 21 CFR 610.16 - Total solids in serums.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Total solids in serums. 610.16 Section 610.16 Food... GENERAL BIOLOGICAL PRODUCTS STANDARDS General Provisions § 610.16 Total solids in serums. Except as... solids. ...

  12. 21 CFR 610.16 - Total solids in serums.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 7 2011-04-01 2010-04-01 true Total solids in serums. 610.16 Section 610.16 Food... GENERAL BIOLOGICAL PRODUCTS STANDARDS General Provisions § 610.16 Total solids in serums. Except as... solids. ...

  13. BiliChek transcutaneous bilirubin meter overestimates serum bilirubin as measured by the Doumas reference method.

    PubMed

    Karon, Brad S; Wickremasinghe, Andrea C; Lo, Stanley F; Saenger, Amy K; Cook, Walter J

    2010-08-01

    To determine the relationship between BiliChek TcB (Respironics, Marietta GA) and Doumas reference serum or plasma total bilirubin (TSB). Pooled samples with values assigned by the Doumas reference method were used to establish the relationship between a local laboratory and reference Doumas TSB. We then established the relationship between TcB and TSB in the 3 months before and after reassignment of calibrator setpoints undertaken to match the local laboratory to Doumas reference bilirubin values. Before calibrator setpoint reassignment TSB as measured in our laboratory overestimated Doumas reference bilirubin. After calibrator adjustment laboratory TSB was within 1.7-6.8 micromol/L (0.1-0.4 mg/dL) of Doumas reference values. Mean bias between BiliChek TcB and TSB was 42.8+/-22.2 micromol/L (2.5+/-1.3mg/dL) (n=94) before and 49.6+/-22.2 micromol/L (2.9+/-1.3mg/dL) (n=115) after calibration adjustment. BiliChek TcB significantly overestimates TSB as measured by the Doumas reference method. 2010 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  14. Serum concentrations of symmetric dimethylarginine and creatinine in cats with kidney stones.

    PubMed

    Hall, Jean A; Yerramilli, Maha; Obare, Edward; Li, Jun; Yerramilli, Murthy; Jewell, Dennis E

    2017-01-01

    Serum concentrations of symmetric dimethylarginine (SDMA) correlate with renal function in cats and SDMA has been shown to be a more reliable and earlier marker for chronic kidney disease (CKD) compared with serum creatinine (Cr). Calcium oxalate uroliths tend to develop in mid-to-older aged cats and kidney stones may cause a reduction in renal function with increased SDMA, but normal serum Cr. The purpose of this retrospective study was to determine if cats with kidney stones had increased serum SDMA concentrations, and whether SDMA increased earlier than serum creatinine concentrations. Cats in the colony with kidney stones diagnosed between August 2010 and December 2015 (n = 43) were compared with healthy geriatric cats (n = 21) without kidney stones. Serum SDMA concentrations were determined by liquid chromatography-mass spectrometry and serum Cr concentrations were determined by enzymatic colorimetry. Cats with kidney stones were diagnosed antemortem by radiographic imaging (n = 12) or by postmortem necropsy (n = 31). Retrospectively, serum SDMA was found to be increased above the upper reference limit in 39 of 43 cats with kidney stones. Serum Cr was increased above the upper reference limit in 18 of 43 cats; 6 of these 18 cats had terminal azotemia only. The mean time that serum SDMA was increased before serum Cr was increased was 26.9 months (range 0 to 60 months). Kidney stones were composed of calcium oxalate in 30 of 34 cats. The lifespan for cats with kidney stones (mean, 12.5 years; range, 6.1 to 18.1 years) was shorter (P < 0.001) than for control cats (mean, 15.2 years; range, 13.0 to 17.2 years), suggesting that non-obstructive kidney stones have an effect on mortality rate or rate of CKD progression. In conclusion, if SDMA concentrations are elevated in mid-to-older aged cats, further imaging studies are warranted to check for the presence of kidney stones.

  15. Serum concentrations of symmetric dimethylarginine and creatinine in cats with kidney stones

    PubMed Central

    Hall, Jean A.; Yerramilli, Maha; Obare, Edward; Li, Jun; Yerramilli, Murthy; Jewell, Dennis E.

    2017-01-01

    Serum concentrations of symmetric dimethylarginine (SDMA) correlate with renal function in cats and SDMA has been shown to be a more reliable and earlier marker for chronic kidney disease (CKD) compared with serum creatinine (Cr). Calcium oxalate uroliths tend to develop in mid-to-older aged cats and kidney stones may cause a reduction in renal function with increased SDMA, but normal serum Cr. The purpose of this retrospective study was to determine if cats with kidney stones had increased serum SDMA concentrations, and whether SDMA increased earlier than serum creatinine concentrations. Cats in the colony with kidney stones diagnosed between August 2010 and December 2015 (n = 43) were compared with healthy geriatric cats (n = 21) without kidney stones. Serum SDMA concentrations were determined by liquid chromatography-mass spectrometry and serum Cr concentrations were determined by enzymatic colorimetry. Cats with kidney stones were diagnosed antemortem by radiographic imaging (n = 12) or by postmortem necropsy (n = 31). Retrospectively, serum SDMA was found to be increased above the upper reference limit in 39 of 43 cats with kidney stones. Serum Cr was increased above the upper reference limit in 18 of 43 cats; 6 of these 18 cats had terminal azotemia only. The mean time that serum SDMA was increased before serum Cr was increased was 26.9 months (range 0 to 60 months). Kidney stones were composed of calcium oxalate in 30 of 34 cats. The lifespan for cats with kidney stones (mean, 12.5 years; range, 6.1 to 18.1 years) was shorter (P < 0.001) than for control cats (mean, 15.2 years; range, 13.0 to 17.2 years), suggesting that non-obstructive kidney stones have an effect on mortality rate or rate of CKD progression. In conclusion, if SDMA concentrations are elevated in mid-to-older aged cats, further imaging studies are warranted to check for the presence of kidney stones. PMID:28384169

  16. Serum biomarkers are similar in Churg-Strauss syndrome and hypereosinophilic syndrome.

    PubMed

    Khoury, P; Zagallo, P; Talar-Williams, C; Santos, C S; Dinerman, E; Holland, N C; Klion, A D

    2012-09-01

    Churg-Strauss syndrome (CSS) and hypereosinophilic syndrome (HES) overlap considerably in clinical presentation. A reliable means of distinguishing between these groups of patients is needed, especially in the setting of glucocorticoid therapy. A retrospective chart review of 276 adult subjects referred for evaluation of eosinophilia > 1500/μl was performed, and subjects with a documented secondary cause of eosinophilia or a PDGFR -positive myeloproliferative neoplasm were excluded. The remaining subjects were assessed for the presence of American College of Rheumatology (ACR) criteria. Laboratory and clinical parameters were compared between subjects with biopsy-proven vasculitis (CSS; n = 8), ≥4 ACR criteria (probable CSS; n = 21), HES with asthma and/or sinusitis without other CSS-defining criteria (HESwAS; n = 20), HES without asthma or sinusitis (HES; n = 18), and normal controls (n = 8). Serum biomarkers reported to be associated with CSS were measured using standard techniques. There were no differences between the subjects with definite or probable CSS or HES with respect to age, gender, or maintenance steroid dose. Serum CCL17, IL-8, and eotaxin levels were significantly increased in eosinophilic subjects as compared to normal controls, but were similar between the eosinophilic groups. Serum CCL17 correlated with eosinophil count (P < 0.0001, r = 0.73), but not with prednisone dose. In patients with a history of asthma and sinusitis, distinguishing between ANCA-negative CSS and PDGFR-negative HES is difficult because of significant overlap in clinical presentation and biomarker profiles. Published 2012. This article is a U.S. Government work and is in the public domain in the USA.

  17. Evaluation of an anal sac adenocarcinoma tumor in a Spitz dog

    PubMed Central

    Javanbakht, Javad; Tavassoli, Abbas; Sabbagh, Atefeh; Hassan, Mehdy Aghamohammmad; Samakkhah, Shohreh Alian; Shafiee, Radmehr; Lakzian, Ali; Ghalee, Vahideh Rahmani; Gharebagh, Sonia Shoja

    2013-01-01

    A 9-year-old emasculated male Spitz with tenesmus and constipation had a subcutaneous mass at the left ventral aspect of the anus with history of polyuria and polydipsia. A complete blood cell count, serum biochemistry panel, and urinalysis (cystocentesis sample) were evaluated. Abnormalities in the serum biochemistry panel included a mildly elevated serum cholesterol concentration (7.28 mmol/L; reference interval, 2.70–5.94 mmol/L), increased serum alkaline phosphatase activity (184 U/L; reference interval, 9–90 U/L), alanine transaminase (122 U/L; reference interval, 5–60 U/L) activity and aspartate aminotransferase (80 U/L; reference interval, 5–55 U/L) activity, severe increased total calcium concentration (16.3 mg/dL; reference interval, 8.2–12.4 mg/dL or 9.3–11.4 mg/dL), and decreased total calcium concentration (3.4 mg/dL, reference interval, 2.5–5.6mg/dL). Furthermore, testing revealed an increased intact parathyroid hormone concentration (38.6 pmol/L; reference interval, 3–17 pmol/L). On cytologic and histopathologic examinations, various types of cells were observed. Most of the cells were oval to polygonal and had elliptical or elongate nuclei and a moderate amount of pale to basophilic cytoplasm. The remaining cells had round to oval nuclei and pale to basophilic cytoplasm. Cells of both types were loosely adhered to each other and were arranged in rosette-like structures. Both neoplastic cell types had fine homogenous chromatin and either a small indistinct nucleolus or no visible nucleolus. Mild anisokaryosis and anisocytosis were observed. Histologically, the mass consists of glandular structures formed by cuboidal cells admixed with bundles of spindle cells. Based on location and histologic features, the final diagnosis was adenocarcinoma of the apocrine gland of the anal sac, which should be included as a cytologic differential diagnosis when spindle cells and typical epithelial cells are observed in masses in the region of the anal sac of dogs. PMID:23570021

  18. Environmental Chemicals in Urine and Blood: Improving Methods for Creatinine and Lipid Adjustment

    PubMed Central

    O’Brien, Katie M.; Upson, Kristen; Cook, Nancy R.; Weinberg, Clarice R.

    2015-01-01

    Background Investigators measuring exposure biomarkers in urine typically adjust for creatinine to account for dilution-dependent sample variation in urine concentrations. Similarly, it is standard to adjust for serum lipids when measuring lipophilic chemicals in serum. However, there is controversy regarding the best approach, and existing methods may not effectively correct for measurement error. Objectives We compared adjustment methods, including novel approaches, using simulated case–control data. Methods Using a directed acyclic graph framework, we defined six causal scenarios for epidemiologic studies of environmental chemicals measured in urine or serum. The scenarios include variables known to influence creatinine (e.g., age and hydration) or serum lipid levels (e.g., body mass index and recent fat intake). Over a range of true effect sizes, we analyzed each scenario using seven adjustment approaches and estimated the corresponding bias and confidence interval coverage across 1,000 simulated studies. Results For urinary biomarker measurements, our novel method, which incorporates both covariate-adjusted standardization and the inclusion of creatinine as a covariate in the regression model, had low bias and possessed 95% confidence interval coverage of nearly 95% for most simulated scenarios. For serum biomarker measurements, a similar approach involving standardization plus serum lipid level adjustment generally performed well. Conclusions To control measurement error bias caused by variations in serum lipids or by urinary diluteness, we recommend improved methods for standardizing exposure concentrations across individuals. Citation O’Brien KM, Upson K, Cook NR, Weinberg CR. 2016. Environmental chemicals in urine and blood: improving methods for creatinine and lipid adjustment. Environ Health Perspect 124:220–227; http://dx.doi.org/10.1289/ehp.1509693 PMID:26219104

  19. Preliminary evaluation of serum total cholesterol concentrations in dogs with osteosarcoma.

    PubMed

    Leeper, H; Viall, A; Ruaux, C; Bracha, S

    2017-10-01

    To determine if total serum cholesterol concentrations were altered in dogs with osteosarcoma. To evaluate association of total serum cholesterol concentration with clinical outcomes in dogs with appendicular osteosarcoma. Retrospective, multi-institutional study on 64 dogs with osteosarcoma. Control population consisted of dogs with traumatic bone fractures (n=30) and healthy patients of similar age and weight as those of the osteosarcoma cases (n=31). Survival analysis was done on 35 appendicular osteosarcoma patients that received the current standard of care. Statistical associations were assessed by univariable and multi-variable analysis. Information about age, sex, primary tumour location, total cholesterol concentration, monocytes and lymphocyte counts and alkaline phosphatase were also included. Total cholesterol was elevated above the reference interval (3·89 to 7·12 mmol/L) (150 to 275 mg/dL) in 29 of 64 (45·3%) osteosarcoma-bearing dogs, whereas similar elevations were found in only 3 of 30 (10%) fracture controls (P<0·0001) and 2 of 31 (6·5%) similar age/weight controls (P=0·0002). Elevated total cholesterol was significantly associated with a reduced hazard ratio (0·27, P=0·008) for overall mortality in dogs with osteosarcoma. These results suggest that elevated total cholesterol is associated with canine osteosarcoma and may have prognostic significance. © 2017 British Small Animal Veterinary Association.

  20. Colon Reference Set Application: Nam Kim - DiaDexus (2008) — EDRN Public Portal

    Cancer.gov

    The EDRN Colorectal reference samples will be useful in confirming the potential application of novel serum markers for colorectal cancer that can detect presence of cancer in high-risk asymptomatic patients.

  1. Occupational exposure levels of bioaerosol components are associated with serum levels of the acute phase protein Serum Amyloid A in greenhouse workers.

    PubMed

    Madsen, Anne Mette; Thilsing, Trine; Bælum, Jesper; Garde, Anne Helene; Vogel, Ulla

    2016-01-20

    Occupational exposure to particles may be associated with increased inflammation of the airways. Animal experiments suggest that inhaled particles also induce a pulmonary acute phase response, leading to systemic circulation of acute phase proteins. Greenhouse workers are exposed to elevated levels of bioaerosols. The objective of this study is to assess whether greenhouse workers personal exposure to bioaerosol components was associated with serum levels of the acute phase proteins Serum Amyloid A (SAA) and C-reactive protein (CRP). SAA and CRP levels were determined in serum sampled repeatedly from 33 greenhouse workers. Blood was drawn repeatedly on Mondays and Thursdays during work weeks. Acute phase protein levels were compared to levels in a comparison group of 42 people and related to individual exposure levels to endotoxin, dust, bacteria, fungi and β-glucan. Serum levels of SAA and CRP were not significantly different in greenhouse workers and a reference group, or on the two work days. In a mixed model, SAA levels were positively associated with endotoxin exposure levels (p = 0.0007). Results for fungi were not clear. CRP levels were positively associated with endotoxin exposures (p = 0.022). Furthermore, when workers were categorized into three groups based on SAA and CRP serum levels endotoxin exposure was highest in the group with the highest SAA levels and in the group with middle and highest CRP levels. SAA and CRP levels were elevated in workers with asthma. Greenhouse workers did not have elevated serum levels of SAA and CRP compared to a reference group. However, occupational exposure to endotoxin was positively associated with serum levels of the acute phase proteins SAA and CRP. Preventive measures to reduce endotoxin exposure may be beneficial.

  2. Prevalence and prognostic importance of hypomagnesemia and hypocalcemia in horses that have colic surgery.

    PubMed

    Garcia-Lopez, J M; Provost, P J; Rush, J E; Zicker, S C; Burmaster, H; Freeman, L M

    2001-01-01

    To determine the prevalence of hypomagnesemia and hypocalcemia in horses with surgical colic. 35 horses with surgically managed colic. Serum concentrations of total magnesium (tMg2+) and calcium (tCa2+), as well as ionized magnesium (iMg2+) and calcium (iCa2+) were analyzed before surgery and 1, 3, 5, and 7 days following surgery. A lead-II ECG and pertinent clinical data were also obtained at each time. Preoperative serum tMg2+ and iMg2+ concentrations were below the reference range in 6 (17%) and 19 (54%) horses, respectively. Serum concentrations of tCa2+ and iCa2+ were less than the reference range in 20 (57%) and 30 (86%) horses before surgery. Horses with strangulating lesions of the gastrointestinal tract had significantly lower preoperative serum concentrations of iMg2+ and iCa2+, as well as a higher heart rate than horses with nonstrangulating lesions. Horses that developed postoperative ileus had significantly lower serum concentrations of iMg2+ after surgery. Serum concentrations of magnesium and calcium (total and ionized) correlated significantly with the PR, QRS, QT, and corrected QT (QTc) intervals. Horses that were euthanatized at the time of surgery (n = 7) had significantly lower preoperative serum concentrations of iMg2+, compared with horses that survived. Neither serum magnesium nor calcium concentrations were predictors of hospitalization time or survival. Hypomagnesemia and hypocalcemia were common during the perioperative period, particularly in horses with strangulating intestinal lesions and ileus. Serum concentrations of tMg2+ and tCa2+ were less sensitive than iMg2+ and iCa2+ in detecting horses with hypomagnesemia and hypocalcemia.

  3. Thyroid function in 36 dogs with leishmaniosis due to Leishmania infantum before and during treatment with allopurinol with or without meglumine antimonate.

    PubMed

    Saridomichelakis, Manolis N; Xenoulis, Panagiotis G; Chatzis, Manolis K; Kasabalis, Dimitris; Steiner, Jörg M; Suchodolski, Jan S; Petanides, Theodoros

    2013-10-18

    Hypothyroidism may predispose to the development of canine leishmaniosis or it may appear during the course of the latter due to infiltration and destruction of the thyroid gland by infected macrophages. The main purpose of this study was to evaluate thyroid function through measurement of serum total thyroxin (tT₄), free thyroxin (fT₄), and canine thyroid stimulating hormone (cTSH) concentrations in 36 dogs with leishmaniosis, before and after 2 and 4 weeks of treatment with allopurinol with or without meglumine antimonate. Before treatment 27/36 (75%) dogs had serum tT₄ concentrations below the lower limit of the reference interval but only 2 of them had concurrently serum fT₄ concentrations below the lower limit of the reference interval and none had increased serum cTSH concentrations. During treatment there were no significant changes in serum tT₄ or fT₄ concentrations, whereas a significant increase in serum cTSH was observed. Two dogs had decreased serum tT₄ and fT₄ but normal cTSH concentrations before treatment and two other dogs had decreased serum tT₄ and increased cTSH, but normal fT₄ concentrations during the treatment period. Although hypothyroidism could not be definitively excluded in these dogs it is considered unlikely based on their overall hormonal profile, clinical presentation, and response to treatment. Therefore, hypothyroidism does not appear to be an important predisposing disease or a frequent complication of canine leishmaniosis. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Serum levels of brominated flame retardants (BFRs: PBDE, HBCD) and influence of dietary factors in a population-based study on Swedish adults.

    PubMed

    Bjermo, Helena; Aune, Marie; Cantillana, Tatiana; Glynn, Anders; Lind, P Monica; Ridefelt, Peter; Darnerud, Per Ola

    2017-01-01

    The aim of this study was to investigate associations between serum concentrations of brominated flame retardants and personal characteristics, including diet, in adults participating in a population-based study in Sweden 2010-11. Moreover, observed concentrations were used in a health risk assessment, using published health-based reference values. Serum samples of 170 adult individuals of both sexes were analyzed for 10 PBDE congeners and HBCD by GC-MS. When including concentrations between LOD and LOQ, highest median serum concentration was observed for BDE-153 (1.2 ng/g serum lipid), followed by BDE-209 (0.95 ng/g lipid), BDE-47 (0.49 ng/g lipid) and BDE-100 (0.21 ng/g lipid). Median concentration of HBCD was 0.10 ng/g lipid. A few markedly elevated concentrations of BDE-209, HBCD (77-78 ng/g lipid) and BDE-47 (44 ng/g lipid) were observed. The only statistical significant findings were higher BDE-153 concentrations in men than in women, and positive associations between serum BDE-153 concentrations and consumption of fish (total), beef, mutton and poultry. PBDE concentrations were in accordance with concentrations reported in other European countries but generally lower than those found in North America. Median PBDE serum concentrations observed in adults from Sweden suggest sufficient health protection, when compared with published health-based reference values, although some outliers with high serum concentrations had lower safety margins. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  5. Evaluation of serum biochemical marker concentrations and survival time in dogs with protein-losing enteropathy.

    PubMed

    Equilino, Mirjam; Théodoloz, Vincent; Gorgas, Daniela; Doherr, Marcus G; Heilmann, Romy M; Suchodolski, Jan S; Steiner, Jörg M; Burgener Dvm, Iwan A

    2015-01-01

    To evaluate serum concentrations of biochemical markers and survival time in dogs with protein-losing enteropathy (PLE). Prospective study. 29 dogs with PLE and 18 dogs with food-responsive diarrhea (FRD). Data regarding serum concentrations of various biochemical markers at the initial evaluation were available for 18 of the 29 dogs with PLE and compared with findings for dogs with FRD. Correlations between biochemical marker concentrations and survival time (interval between time of initial evaluation and death or euthanasia) for dogs with PLE were evaluated. Serum C-reactive protein concentration was high in 13 of 18 dogs with PLE and in 2 of 18 dogs with FRD. Serum concentration of canine pancreatic lipase immunoreactivity was high in 3 dogs with PLE but within the reference interval in all dogs with FRD. Serum α1-proteinase inhibitor concentration was less than the lower reference limit in 9 dogs with PLE and 1 dog with FRD. Compared with findings in dogs with FRD, values of those 3 variables in dogs with PLE were significantly different. Serum calprotectin (measured by radioimmunoassay and ELISA) and S100A12 concentrations were high but did not differ significantly between groups. Seventeen of the 29 dogs with PLE were euthanized owing to this disease; median survival time was 67 days (range, 2 to 2,551 days). Serum C-reactive protein, canine pancreatic lipase immunoreactivity, and α1-proteinase inhibitor concentrations differed significantly between dogs with PLE and FRD. Most initial biomarker concentrations were not predictive of survival time in dogs with PLE.

  6. Assessment of thyroid function during first-trimester pregnancy: what is the rational upper limit of serum TSH during the first trimester in Chinese pregnant women?

    PubMed

    Li, Chenyan; Shan, Zhongyan; Mao, Jinyuan; Wang, Weiwei; Xie, Xiaochen; Zhou, Weiwei; Li, Chenyang; Xu, Bin; Bi, Lihua; Meng, Tao; Du, Jianling; Zhang, Shaowei; Gao, Zhengnan; Zhang, Xiaomei; Yang, Liu; Fan, Chenling; Teng, Weiping

    2014-01-01

    Guidelines of the American Thyroid Association (ATA) proposed that the upper limit of the TSH reference range should be 2.5 mIU/L in first trimester, but the reported ranges in China are significantly higher. Our objective was to establish a rational reference range of serum TSH for diagnosis of subclinical hypothyroidism in the first trimester of pregnant women in China. We screened 4800 pregnant women in the first trimester and 2000 women who planned to become pregnant and evaluated 535 pregnant women in follow-up visits during the second and third trimester. Median concentrations of serum TSH decreased significantly from the seventh week of gestation. The median of TSH from 4 to 6 weeks was significantly higher than from 7 to 12 weeks (2.15 [0.56-5.31] mIU/L vs 1.47 [0.10-4.34] mIU/L, P<.001); however, there was no significant difference compared with nonpregnant women (2.07 [0.69-5.64] mIU/L; P=.784). The median of free T4 was not significantly altered in the first trimester. The prevalence of subclinical hypothyroidism in the 4800 pregnant women was 27.8% on the diagnostic criteria of TSH>2.5 mIU/L and 4.0% using the reference interval derived by our laboratory (0.14-4.87 mIU/L).Additionally, of 118 pregnant women who had serum TSH>2.5 mIU/L in the first trimester, only 30.0% and 20.3% of them at the 20th and 30th week of gestation had TSH>3.0 mIU/L. The reference range for nonpregnant women can be used for the assessment of pregnant women at 4 to 6 weeks of gestation. The upper limit of serum TSH in the first trimester was much higher than 2.5 mIU/L in Chinese pregnant women.

  7. Comparison of methods used to diagnose generalized inflammatory disease in manatees (Trichechus manatus latirostris)

    USGS Publications Warehouse

    Harr, K.E.; Harvey, J.W.; Bonde, R.K.; Murphy, D.; Lowe, Mark; Menchaca, M.; Haubold, E.M.; Francis-Floyd, R.

    2006-01-01

    Manatees (Trichechus manatus latirostris) are afflicted with inflammatory and infectious disease secondary to human interaction, such as boat strike and entanglement, as well as “cold stress syndrome” and pneumonia. White-blood-cell count and fever, primary indicators of systemic inflammation in most species, are insensitive in diagnosing inflammatory disease in manatees. Acute phase-response proteins, such as haptoglobin and serum amyloid A, have proven to be sensitive measures of inflammation/infection in domestic large animal species. This study assessed diagnosis of generalized inflammatory disease by different methods including total white-blood-cell count, albumin: globulin ratio, gel electrophoresis analysis, C-reactive protein, alpha1 acid glycoprotein, haptoglobin, fibrinogen, and serum amyloid A. Samples were collected from 71 apparently healthy and 27 diseased animals during diagnostic medical examination. Serum amyloid A, measured by ELISA, followed by albumin:globulin ratio, measured by plasma gel electrophoresis, were most sensitive in diagnosing inflammatory disease, with diagnostic sensitivity and specificity of approximately 90%. The reference interval for serum amyloid A is <10–50 μg/ml with an equivocal interval of 51–70 μg/ml. The reference interval for albumin:globulin ratio by plasma gel electrophoresis is 0.7–1.1. Albumin: globulin ratio, calculated using biochemical techniques, was not accurate due to overestimation of albumin by bromcresol green dye-binding methodology. Albumin:globulin ratio, measured by serum gel electrophoresis, has a low sensitivity of 15% due to the lack of fibrinogen in the sample. Haptoglobin, measured by hemoglobin titration, had a reference interval of 0.4–2.4 mg/ml, a diagnostic sensitivity of 60%, and a diagnostic specificity of 93%. The haptoglobin assay is significantly affected by hemolysis. Fibrinogen, measured by heat precipitation, has a reference interval of 100–400 mg/dl, a diagnostic sensitivity of 40%, and a diagnostic specificity of 95%.

  8. Comparison of methods used to diagnose generalized inflammatory disease in manatees (Trichechus manatus latirostris).

    PubMed

    Harr, Kendal; Harvey, John; Bonde, Robert; Murphy, David; Lowe, Mark; Menchaca, Maya; Haubold, Elsa; Francis-Floyd, Ruth

    2006-06-01

    Manatees (Trichechus manatus latirostris) are afflicted with inflammatory and infectious disease secondary to human interaction, such as boat strike and entanglement, as well as "cold stress syndrome" and pneumonia. White-blood-cell count and fever, primary indicators of systemic inflammation in most species, are insensitive in diagnosing inflammatory disease in manatees. Acute phase-response proteins, such as haptoglobin and serum amyloid A, have proven to be sensitive measures of inflammation/infection in domestic large animal species. This study assessed diagnosis of generalized inflammatory disease by different methods including total white-blood-cell count, albumin: globulin ratio, gel electrophoresis analysis, C-reactive protein, alpha, acid glycoprotein, haptoglobin, fibrinogen, and serum amyloid A. Samples were collected from 71 apparently healthy and 27 diseased animals during diagnostic medical examination. Serum amyloid A, measured by ELISA, followed by albumin:globulin ratio, measured by plasma gel electrophoresis, were most sensitive in diagnosing inflammatory disease, with diagnostic sensitivity and specificity of approximately 90%. The reference interval for serum amyloid A is <10-50 microg/ml with an equivocal interval of 51-70 microg/ml. The reference interval for albumin:globulin ratio by plasma gel electrophoresis is 0.7-1.1. Albumin: globulin ratio, calculated using biochemical techniques, was not accurate due to overestimation of albumin by bromcresol green dye-binding methodology. Albumin:globulin ratio, measured by serum gel electrophoresis, has a low sensitivity of 15% due to the lack of fibrinogen in the sample. Haptoglobin, measured by hemoglobin titration, had a reference interval of 0.4-2.4 mg/ml, a diagnostic sensitivity of 60%, and a diagnostic specificity of 93%. The haptoglobin assay is significantly affected by hemolysis. Fibrinogen, measured by heat precipitation, has a reference interval of 100-400 mg/dl, a diagnostic sensitivity of 40%, and a diagnostic specificity of 95%.

  9. Serum biomarkers for the early diagnosis of TIA: The MIND-TIA study protocol.

    PubMed

    Dolmans, L Servaas; Rutten, Frans H; El Bartelink, Marie-Louise; Seppenwoolde, Gerdien; van Delft, Sanne; Kappelle, L Jaap; Hoes, Arno W

    2015-07-28

    A Transient Ischaemic Attack (TIA) bears a high risk of a subsequent ischaemic stroke. Adequate diagnosis of a TIA should be followed immediately by the start of appropriate preventive therapy, including antiplatelets. The diagnosis of a TIA based on symptoms and signs only is notoriously difficult and biomarkers of brain ischaemia might improve the recognition, and target management and prognosis of TIA patients. Our aim is to quantify the added diagnostic value of serum biomarkers of brain ischaemia in patients suspected of TIA. a cross-sectional diagnostic accuracy study with an additional six month follow-up period. 350 patients suspected of TIA in the primary care setting. Patients suspected of a TIA will be recruited by at least 200 general practitioners (GPs) in the catchment area of seven TIA outpatient clinics willing to participate in the study. In all patients a blood sample will be drawn as soon as possible after the patient has contacted the GP, but at least within 72 h after onset of symptoms. Participants will be referred by the GP to the regional TIA outpatient clinic for additional investigations, including brain imaging. The 'definite' diagnosis (reference standard) will be made by a panel consisting of three experienced neurologists who will use all available diagnostic information and the clinical information obtained during the outpatient clinic assessment, and a six month follow-up period. The diagnostic accuracy, and value in addition to signs and symptoms of candidate serum biomarkers will be assessed in terms of discrimination with C statistics, and calibration with plots. We aim to include 350 suspected cases, with 250 patients with indeed definite TIA (or minor stroke) according to the panel. We hope to find novel biomarkers that will enable a rapid and accurate diagnosis of TIA. This would largely improve the management and prognosis of such patients. ClinicalTrials.gov Identifier NCT01954329.

  10. Serum 25-hydroxyvitamin D and breast cancer in the military: a case-control study utilizing pre-diagnostic serum.

    PubMed

    Mohr, Sharif B; Gorham, Edward D; Alcaraz, John E; Kane, Christopher I; Macera, Caroline A; Parsons, J Kellogg; Wingard, Deborah L; Horst, Ronald; Garland, Cedric F

    2013-03-01

    The objective of this study was to ascertain whether a relationship exists between pre-diagnostic serum levels of 25-hydroxyvitamin D (25(OH)D) and risk of breast cancer in young women. About 600 incident cases of breast cancer were matched to 600 controls as part of a nested case-control study that utilized pre-diagnostic sera. Logistic regression was used to assess the relationship between serum 25(OH)D concentration and breast cancer risk, controlling for race and age. According to the conditional logistic regression for all subjects, odds ratios for breast cancer by quintile of serum 25(OH)D from lowest to highest were 1.2, 1.0, 0.9, 1.1, and 1.0 (reference) (p trend = 0.72). After multivariate regression for subjects whose blood had been collected within 90 days preceding diagnosis, odds ratios for breast cancer by quintile of serum 25(OH)D from lowest to highest were 3.3, 1.9, 1.7, 2.6, and 1.0 (reference) (p trend = 0.09). An inverse association between serum 25(OH)D concentration and risk of breast cancer was not present in the principal analysis, although an inverse association was present in a small subgroup analysis of subjects whose blood had been collected within 90 days preceding diagnosis. Further prospective studies of 25(OH)D and breast cancer risk are needed.

  11. [Impaired renal function: be aware of exogenous factors].

    PubMed

    van der Meijden, Wilbert A G; Smak Gregoor, Peter J H

    2013-01-01

    Renal function is currently estimated using the Modification of Diet in Renal Disease (MDRD) formula, which is partly based on the serum creatinine level. Patients with impaired renal function are referred to nephrologists in accordance with the Dutch national transmural agreement for 'Chronic renal impairment'. A 54-year-old woman without significant history was referred to analyse a coincidentally found decline in the estimated glomerular filtration rate (eGFR). The patient had no complaints and used no medication except creatine supplements. Additional diagnostic testing showed no abnormalities. After cessation of creatine supplementation, the calculated renal function normalized. Serum creatinine is a reflection of muscle mass. The use of creatine-containing dietary supplements, such as creatine ethyl ester, can influence serum creatinine levels and therefore the eGFR as calculated with the MDRD formula. The use of supplements deserves attention when taking the history.

  12. Final report on EURAMET.QM-K12: EURAMET key comparison on the determination of the mass fraction of creatinine in serum

    NASA Astrophysics Data System (ADS)

    Bell, David; Hopley, Chris; Ellison, Stephen L. R.; O'Connor, Gavin

    2013-01-01

    Creatinine is a well-known marker for the evaluation of kidney function. Its routine measurement is undertaken by many clinical laboratories and comparable results over distance and time are required for effective diagnosis. To address this need many National Measurement Institutes (or designated institutes) provide services in this area via the provision of higher order standards or reference measurements. The organic analysis working group of the consultative committee for amount of substance have conducted two previous key comparisons to assess the equivalence of institutes who provide such services. The purpose of this study was to enable institutes who missed the previous studies to demonstrate their capability for characterizing serum materials containing 1 µg/g to 100 µg/g of creatinine. The study material consisted of two lyophilized serum samples which were used in an external quality control proficiency testing scheme. No target values were available for these materials and all participants reported results within the one month timeframe given for analysis. Five institutes participated in the key study and a single institute submitted results for the parallel pilot study. All participants in the key study used isotope dilution with either gas or liquid chromatography coupled with mass spectrometry. The pilot study laboratory used a novel isotope dilution surface-enhanced Raman spectroscopy method. The comparison reference value for each material was set as the mean of all results submitted by those participating in the key study. The choice of the reference value estimator was constrained as it was deemed more appropriate to treat the data in a similar manner to CCQM-K12 if the relative degrees of equivalence were to be compared. This resulted in reference values of (54.27 ± 0.72) µg/g and (38.01 ± 0.42) µg/g for the two separate materials. The relative degrees of equivalence were calculated and these were compared with the relative degrees of equivalence of participants in CCQM-K12. The range of participants' results in EURAMET.QM-K12 for both levels (2% and 3% respectively for materials A and B) was greater than the 1% achieved in CCQM-K12. However, it was concluded that this study was suitable to support CMCs for creatinine in serum for 1 µg/g to 100 µg/g with uncertainties at the 1% to 1.5% level. This was found to be fit for purpose and consistent with the majority of CMCs currently approved. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  13. Reference Intervals of Alpha-Fetoprotein and Carcinoembryonic Antigen in the Apparently Healthy Population

    PubMed Central

    Zhang, Gao-Ming; Guo, Xu-Xiao; Ma, Xiao-Bo; Zhang, Guo-Ming

    2016-01-01

    Background The aim of this study was to calculate 95% reference intervals and double-sided limits of serum alpha-fetoprotein (AFP) and carcinoembryonic antigen (CEA) according to the CLSI EP28-A3 guideline. Material/Methods Serum AFP and CEA values were measured in samples from 26 000 healthy subjects in the Shuyang area receiving general health checkups. The 95% reference intervals and upper limits were calculated by using MedCalc. Results We provided continuous reference intervals from 20 years old to 90 years old for AFP and CEA. The reference intervals were: AFP, 1.31–7.89 ng/ml (males) and 1.01–7.10 ng/ml (females); CEA, 0.51–4.86 ng/ml (males) and 0.35–3.45ng/ml (females). AFP and CEA were significantly positively correlated with age in both males (r=0.196 and r=0.198) and females (r=0.121 and r=0.197). Conclusions Different races or populations and different detection systems may result in different reference intervals for AFP and CEA. Continuous reference intervals of age changes are more accurate than age groups. PMID:27941709

  14. Variation of calcium, copper and iron levels in serum, bile and stone samples of patients having different types of gallstone: A comparative study.

    PubMed

    Khan, Mustafa; Kazi, Tasneem Gul; Afridi, Hassan Imran; Sirajuddin; Bilal, Muhammad; Akhtar, Asma; Khan, Sabir; Kadar, Salma

    2017-08-01

    Epidemiological data among the human population has shown a significantly increased incidence of gallstone (GS) disease worldwide. It was studied that some essential (calcium) and transition elements (iron and copper) in bile play an important role in the development of GS. The estimation of calcium, copper and iron were carried out in the serum, gall bladder bile and different types of GS (cholesterol, mixed and pigmented) of 172 patients, age ranged 20-55years. For comparative purpose age matched referents not suffering from GS diseases were also selected. Biliary concentrations of calcium (Ca), iron (Fe) and copper (Cu) were correlated with their concentrations in serum and different types of GS samples. The ratio of Ca, Fe and Cu in bile with serum was also calculated. Understudy metals were determined by flame atomic absorption spectroscopy after acid decomposition of matrices of selected samples. The Ca concentrations in serum samples were significantly higher in patients with pigmented GS as compared to controls (p<0.005), whereas for patients having cholesterol and mixed GS the concentrations were on the lower side. Biliary Ca concentrations of patients were found to be higher than controls, but difference was significant for pigmented GS patients (p>0.001). The contents of Cu and Fe in serum and bile of all patients (except female cholesterol GS patient have low serum iron concentration) were found to be higher than control, but difference was significant in those patients who have pigmented GS. The concentration of Ca, Fe and Cu in different types GS were found in the order, Pigmented>mixed>cholesterol. The bile/serum ratio for Ca, Cu and Fe was found to be significantly higher in pigmented GS patients. Gall bladder bile was slightly alkaline in patients as compared to referents. The density of bile was found to be higher in patients as compared to the referents. Various functional groups present in different types of GS samples were confirmed by Fourier transform infra-red spectroscopy. The higher density and pH of bile, elevated concentrations of transition elements in all types of biological samples (serum, bile and GS), could be an important factor for the formation of different types of GS. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. 25-Hydroxyvitamin-D3 serum modulation after use of sunbeds compliant with European Union standards: A randomized open observational controlled trial.

    PubMed

    Weber, Benedikt; Bachmann, Chantal C; Braun, Ralph; Abraham, Alison G; Serra, Andreas L; Hofbauer, Günther F L

    2017-07-01

    Regular use of sunbed exposure has been reported to increase 25-hydroxyvitamin-D3 [25(OH)D] serum levels. However, the influence of sunbeds compliant with the recent European Union standard EN-60335-2-27 on 25(OH)D serum levels is unknown. We investigated the impact of standard sunbed use compliant with the European Union standard on 25(OH)D serum modulation and well-being. In a randomized controlled study, 25(OH)D serum levels were measured at enrollment, after 1 week, and after completion of the 12-week period of sunbed use with twice weekly exposure and compared with the control group without any sunbed exposure. In the sunbed intervention group (N = 31), a 27% increase of mean 25(OH)D levels was noted 1 week after starting sunbed use (P < .01). However, after 12 weeks, mean 25(OH)D levels had declined and were no longer different from baseline (P = .06). After 12 weeks, 25(OH)D levels did not differ between the intervention and control group (P = .36). Also the 5-item World Health Organization Well-Being Index score did not differ between the sunbed and control groups (P = .19). For ethical reasons recruitment was limited to persons actively seeking sunbed exposure. Standard use of sunbeds compliant with the European Union standard induced a transient increase of 25(OH)D levels, whereas no change in well-being was observed. Copyright © 2017 American Academy of Dermatology, Inc. Published by Elsevier Inc. All rights reserved.

  16. Validation of an enzyme-linked immunosorbent assay for the quantification of human IgG directed against the repeat region of the circumsporozoite protein of the parasite Plasmodium falciparum

    PubMed Central

    2012-01-01

    Background Several pre-erythrocytic malaria vaccines based on the circumsporozoite protein (CSP) antigen of Plasmodium falciparum are in clinical development. Vaccine immunogenicity is commonly evaluated by the determination of anti-CSP antibody levels using IgG-based assays, but no standard assay is available to allow comparison of the different vaccines. Methods The validation of an anti-CSP repeat region enzyme-linked immunosorbent assay (ELISA) is described. This assay is based on the binding of serum antibodies to R32LR, a recombinant protein composed of the repeat region of P. falciparum CSP. In addition to the original recombinant R32LR, an easy to purify recombinant His-tagged R32LR protein has been constructed to be used as solid phase antigen in the assay. Also, hybridoma cell lines have been generated producing human anti-R32LR monoclonal antibodies to be used as a potential inexhaustible source of anti-CSP repeats standard, instead of a reference serum. Results The anti-CSP repeats ELISA was shown to be robust, specific and linear within the analytical range, and adequately fulfilled all validation criteria as defined in the ICH guidelines. Furthermore, the coefficient of variation for repeatability and intermediate precision did not exceed 23%. Non-interference was demonstrated for R32LR-binding sera, and the assay was shown to be stable over time. Conclusions This ELISA, specific for antibodies directed against the CSP repeat region, can be used as a standard assay for the determination of humoral immunogenicity in the development of any CSP-based P. falciparum malaria vaccine. PMID:23173602

  17. α-Lactalbumin and casein-glycomacropeptide do not affect iron absorption from formula in healthy term infants.

    PubMed

    Szymlek-Gay, Ewa A; Lönnerdal, Bo; Abrams, Steven A; Kvistgaard, Anne S; Domellöf, Magnus; Hernell, Olle

    2012-07-01

    Iron absorption from infant formula is relatively low. α-Lactalbumin and casein-glycomacropeptide have been suggested to enhance mineral absorption. We therefore assessed the effect of α-lactalbumin and casein-glycomacropeptide on iron absorption from infant formula in healthy term infants. Thirty-one infants were randomly assigned to receive 1 of 3 formulas (4 mg iron/L, 13.1 g protein/L) from 4-8 wk to 6 mo of age: commercially available whey-predominant standard infant formula (standard formula), α-lactalbumin-enriched infant formula (α-LAC), or α-lactalbumin-enriched/casein-glycomacropeptide-reduced infant formula (α-LAC/RGMP). Nine breast-fed infants served as a reference. At 5.5 mo of age, (58)Fe was administered to all infants in a meal. Blood samples were collected 14 d later for iron absorption and iron status indices. Iron deficiency was defined as depleted iron stores, iron-deficient erythropoiesis, or iron deficiency anemia. Iron absorption (mean ± SD) was 10.3 ± 7.0% from standard formula, 8.6 ± 3.8% from α-LAC, 9.2 ± 6.5% from α-LAC/RGMP, and 12.9 ± 6.5% from breast milk, with no difference between the formula groups (P = 0.79) or all groups (P = 0.44). In the formula-fed infants only, iron absorption was negatively correlated with serum ferritin (r = -0.49; P = 0.005) and was higher (P = 0.023) in iron-deficient infants (16.4 ± 12.4%) compared with those with adequate iron status (8.6 ± 4.4%). Our findings indicate that α-lactalbumin and casein-glycomacropeptide do not affect iron absorption from infant formula in infants. Low serum ferritin concentrations are correlated with increased iron absorption from infant formula.

  18. [The selenium content of food products and the blood of inhabitants of Norilsk].

    PubMed

    Golubkina, N A; Shagova, M V; Spirichev, V B; Khristenko, P P; Alftan, D; Laaksonen, P; Muratov, Iu M; Vachaeva, N N

    1992-01-01

    The intake of trace element selenium by Norilsk citizens was assessed by its levels in the serum, food and soil. It was found that soil and food made in the Norilsk region are rich in selenium, its serum concentration in the population is normal (102 micrograms/l). References to such values for the Moscow and Zaporoje (Ukraine) regions are made. Low selenium levels in the serum may be indicative of pulmonary diseases.

  19. Proteomic evaluation of sheep serum proteins

    PubMed Central

    2012-01-01

    Background The applications of proteomic strategies to ovine medicine remain limited. The definition of serum proteome may be a good tool to identify useful protein biomarkers for recognising sub-clinical conditions and overt disease in sheep. Findings from bovine species are often directly translated for use in ovine medicine. In order to characterize normal protein patterns and improve knowledge of molecular species-specific characteristics, we generated a two-dimensional reference map of sheep serum. The possible application of this approach was tested by analysing serum protein patterns in ewes with mild broncho-pulmonary disease, which is very common in sheep and in the peripartum period which is a stressful time, with a high incidence of infectious and parasitic diseases. Results This study generated the first reference 2-DE maps of sheep serum. Overall, 250 protein spots were analyzed, and 138 identified. Compared with healthy sheep, serum protein profiles of animals with rhino-tracheo-bronchitis showed a significant decrease in protein spots identified as transthyretin, apolipoprotein A1 and a significant increase in spots identified as haptoglobin, endopin 1b and alpha1B glycoprotein. In the peripartum period, haptoglobin, alpha-1-acid glycoprotein, apolipoprotein A1 levels rose, while transthyretin content dropped. Conclusions This study describes applications of proteomics in putative biomarker discovery for early diagnosis as well as for monitoring the physiological and metabolic situations critical for ovine welfare. PMID:22630135

  20. Serum copper, follicular stimulating hormone, luteinizing hormone, prolactin, spermatic count, viability, progression and seminal zinc correlations in a human (male) infertility study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sella, G.E.; Cunnane, S.C.; McInnes, R.A.

    1981-06-01

    The role of copper and its correlations to other parameters has been investigated in a male-fertility pilot study at a University infertility clinic in Montreal. Serum and semen Cu concentrations were determined in 100 men (age 25 to 54 years) referred to the clinic for infertility evaluation. The results of the significant correlations between serum Cu concentrations and male fertility parameters such as (1) the serum concentrations of the hormones FSH, LH and prolactin; (2) spermatozoal count, viability and progression and (3) seminal zinc concentrations are reported.

  1. Determination of dapsone in serum and saliva using reversed-phase high-performance liquid chromatography with ultraviolet or electrochemical detection.

    PubMed

    Moncrieff, J

    1994-03-18

    A simple, extractionless method for the determination of dapsone in serum and saliva is described. Reversed-phase high-performance liquid chromatography is used with UV detection at 295 nm or electrochemical detection at 0.7 V. Diazoxide in buffer is the internal standard for UV detection and practolol for electrochemical detection. Sample preparation is minimal with protein precipitation of serum samples whilst saliva samples are simply diluted with addition of an internal standard. Low-level serum and saliva samples are front-cut on-line with a 3 cm laboratory-made precolumn in the loop position on a standard Valco injection valve. Isocratic separation is achieved on a 250 mm x 4.6 mm I.D. stainless-steel Spherisorb S5 ODS-1 column. The mobile phase for high levels of dapsone is acetonitrile-elution buffer (12:88, v/v) at 2 ml/min and a column temperature of 40 degrees C for both serum and saliva separations. For the low-level assays using electrochemical detection and solid-phase clean-up, the mobile phase is acetonitrile-methanol-elution buffer (9:4:87, v/v/v). The UV and electrochemical detection limits are 25 ng/ml and 200 pg/ml, respectively, in both serum and saliva. This simple method is applicable to the routine monitoring of dapsone levels in serum from leprotic patients and electrochemical detection gives a simple, reliable method for the monitoring of trough values in subjects on anti-malarial prophylaxis.

  2. [Geographical distribution of the Serum creatinine reference values of healthy adults].

    PubMed

    Wei, De-Zhi; Ge, Miao; Wang, Cong-Xia; Lin, Qian-Yi; Li, Meng-Jiao; Li, Peng

    2016-11-20

    To explore the relationship between serum creatinine (Scr) reference values in healthy adults and geographic factors and provide evidence for establishing Scr reference values in different regions. We collected 29 697 Scr reference values from healthy adults measured by 347 medical facilities from 23 provinces, 4 municipalities and 5 autonomous regions. We chose 23 geographical factors and analyzed their correlation with Scr reference values to identify the factors correlated significantly with Scr reference values. According to the Principal component analysis and Ridge regression analysis, two predictive models were constructed and the optimal model was chosen after comparison of the two model's fitting degree of predicted results and measured results. The distribution map of Scr reference values was drawn using the Kriging interpolation method. Seven geographic factors, including latitude, annual sunshine duration, annual average temperature, annual average relative humidity, annual precipitation, annual temperature range and topsoil (silt) cation exchange capacity were found to correlate significantly with Scr reference values. The overall distribution of Scr reference values featured a pattern that the values were high in the south and low in the north, varying consistently with the latitude change. The data of the geographic factors in a given region allows the prediction of the Scr values in healthy adults. Analysis of these geographical factors can facilitate the determination of the reference values specific to a region to improve the accuracy for clinical diagnoses.

  3. An Assessment of 25-Hydroxyvitamin D Measurements in Comparability Studies Conducted by the Vitamin D Metabolites Quality Assurance Program

    PubMed Central

    Bedner, Mary; Lippa, Katrice A.; Tai, Susan S.-C.

    2013-01-01

    Background The National Institute of Standards and Technology (NIST), in collaboration with the National Institutes of Health Office of Dietary Supplements, established the first accuracy-based program for improving the comparability of vitamin D metabolite measurements, the Vitamin D Metabolites Quality Assurance Program. Methods Study samples were comprised of human serum or plasma Standard Reference Materials (SRMs) with 25-hydroxyvitamin D values that were determined at NIST. Participants evaluated the materials using immunoassay (IA), liquid chromatography (LC) with mass spectrometric detection, and LC with ultraviolet absorbance detection. NIST evaluated the results for concordance within the participant community as well as trueness relative to the NIST value. Results For the study materials that contain mostly 25-hydroxyvitamin D3 (25(OH)D3), the coefficient of variation (CV) for the participant results was consistently in the range from 7% to 19%, and the median values were biased high relative to the NIST values. However, for materials that contain significant concentrations of both 25-hydroxyvitamin D2 (25(OH)D2) and 25(OH)D3, the median IA results were biased lower than both the LC and the NIST values, and the CV was as high as 28%. The first interlaboratory comparison results for SRM 972a Vitamin D Metabolites in Human Serum are also reported. Conclusions Relatively large within-lab and between-lab variability hinders conclusive assessments of bias and accuracy. PMID:23978484

  4. Quality specifications for the extra-analytical phase of laboratory testing: Reference intervals and decision limits.

    PubMed

    Ceriotti, Ferruccio

    2017-07-01

    Reference intervals and decision limits are a critical part of the clinical laboratory report. The evaluation of their correct use represents a tool to verify the post analytical quality. Four elements are identified as indicators. 1. The use of decision limits for lipids and glycated hemoglobin. 2. The use, whenever possible, of common reference values. 3. The presence of gender-related reference intervals for at least the following common serum measurands (besides obviously the fertility relate hormones): alkaline phosphatase (ALP), alanine aminotransferase (ALT), creatine kinase (CK), creatinine, gamma-glutamyl transferase (GGT), IgM, ferritin, iron, transferrin, urate, red blood cells (RBC), hemoglobin (Hb) and hematocrit (Hct). 4. The presence of age-related reference intervals. The problem of specific reference intervals for elderly people is discussed, but their use is not recommended; on the contrary it is necessary the presence of pediatric age-related reference intervals at least for the following common serum measurands: ALP, amylase, creatinine, inorganic phosphate, lactate dehydrogenase, aspartate aminotransferase, urate, insulin like growth factor 1, white blood cells, RBC, Hb, Hct, alfa-fetoprotein and fertility related hormones. The lack of such reference intervals may imply significant risks for the patients. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  5. The Human Serum Metabolome

    PubMed Central

    Psychogios, Nikolaos; Hau, David D.; Peng, Jun; Guo, An Chi; Mandal, Rupasri; Bouatra, Souhaila; Sinelnikov, Igor; Krishnamurthy, Ramanarayan; Eisner, Roman; Gautam, Bijaya; Young, Nelson; Xia, Jianguo; Knox, Craig; Dong, Edison; Huang, Paul; Hollander, Zsuzsanna; Pedersen, Theresa L.; Smith, Steven R.; Bamforth, Fiona; Greiner, Russ; McManus, Bruce; Newman, John W.; Goodfriend, Theodore; Wishart, David S.

    2011-01-01

    Continuing improvements in analytical technology along with an increased interest in performing comprehensive, quantitative metabolic profiling, is leading to increased interest pressures within the metabolomics community to develop centralized metabolite reference resources for certain clinically important biofluids, such as cerebrospinal fluid, urine and blood. As part of an ongoing effort to systematically characterize the human metabolome through the Human Metabolome Project, we have undertaken the task of characterizing the human serum metabolome. In doing so, we have combined targeted and non-targeted NMR, GC-MS and LC-MS methods with computer-aided literature mining to identify and quantify a comprehensive, if not absolutely complete, set of metabolites commonly detected and quantified (with today's technology) in the human serum metabolome. Our use of multiple metabolomics platforms and technologies allowed us to substantially enhance the level of metabolome coverage while critically assessing the relative strengths and weaknesses of these platforms or technologies. Tables containing the complete set of 4229 confirmed and highly probable human serum compounds, their concentrations, related literature references and links to their known disease associations are freely available at http://www.serummetabolome.ca. PMID:21359215

  6. Increased longitudinal growth in rats on a silicon-depleted diet☆

    PubMed Central

    Jugdaohsingh, Ravin; Calomme, Mario R.; Robinson, Karen; Nielsen, Forrest; Anderson, Simon H.C.; D'Haese, Patrick; Geusens, Piet; Loveridge, Nigel; Thompson, Richard P.H.; Powell, Jonathan J.

    2008-01-01

    Silicon-deficiency studies in growing animals in the early 1970s reported stunted growth and profound defects in bone and other connective tissues. However, more recent attempts to replicate these findings have found mild alterations in bone metabolism without any adverse health effects. Thus the biological role of silicon remains unknown. Using a specifically formulated silicon-depleted diet and modern methods for silicon analysis and assessment of skeletal development, we undertook, through international collaboration between silicon researchers, an extensive study of long-term silicon depletion on skeletal development in an animal. 21-day old female Sprague–Dawley rats (n = 20) were fed a silicon-depleted diet (3.2 µg Si/g feed) for 26 weeks and their growth and skeletal development were compared with identical rats (n = 10) on the same diet but with silicon added as Si(OH)4 to their drinking water (53.2 µg Si/g water); total silicon intakes were 24 times different. A third group of rats, receiving a standard rodent stock feed (322 µg Si/g feed) and tap water (5 µg Si/g water), served as a reference group for optimal growth. A series of anthropometric and bone quality measures were undertaken during and following the study. Fasting serum silicon concentrations and especially urinary silicon excretion were significantly lower in the silicon-deprived group compared to the supplemented group (P = 0.03 and 0.004, respectively). Tibia and soft-tissue silicon contents did not differ between the two groups, but tibia silicon levels were significantly lower compared to the reference group (P < 0.0001). Outward adverse health effects were not observed in the silicon-deprived group. However, body lengths from week 18 onwards (P < 0.05) and bone lengths at necropsy (P ≤ 0.002) were longer in this group. Moreover, these measures correlated inversely with serum silicon concentrations (P ≤ 0.02). A reduction in bone growth plate thickness and an apparent increase in chondrocyte density were also observed in the silicon-deprived animals. No other differences were observed between the two groups, except for tibia phosphorus concentrations, which were lower in the silicon-deprived animals (P = 0.0003). Thus in this study we were unable to reproduce the profound deficiency state reported in rats and chicks in the early 1970s. Indeed, although silicon intake and circulating fasting serum levels differed between the silicon-deprived and silicon-supplemented animals, tibia and soft-tissue levels did not and may explain the lack of difference in bone quality and bone markers (except serum CTx) between these two groups. Markedly higher tibia silicon levels in the reference group and nutritional differences between the formulated low-Si and reference diets suggest that one or more co-factors may be absent from the low-Si diet that affect silicon incorporation into bone. However, evidence for urinary silicon conservation (to maintain tissue levels), changes in bone/body lengths, bone calcium:phosphorus ratio and differences at the growth plate with silicon deprivation are all novel and deserve further study. These results suggest that rats actively maintain body silicon levels via urinary conservation, but the low circulating serum silicon levels during silicon deficiency result in inhibition of growth plate closure and increased longitudinal growth. Silicon-responsive genes and Si transporters are being investigated in the kidneys of these rats. PMID:18550464

  7. Enoxacin penetration into human prostatic tissue.

    PubMed Central

    Bergeron, M G; Roy, R; Lessard, C; Foucault, P

    1988-01-01

    Concurrent enoxacin concentrations in serum and prostatic tissue were determined in 14 patients. The mean ratios of enoxacin concentration in tissue over concentration in serum were 1.4 +/- 0.2 (standard error of the mean). The levels in serum and prostatic tissue were above the MICs for most urinary pathogens. PMID:3196004

  8. Comparative analyses of industrial-scale human platelet lysate preparations.

    PubMed

    Pierce, Jan; Benedetti, Eric; Preslar, Amber; Jacobson, Pam; Jin, Ping; Stroncek, David F; Reems, Jo-Anna

    2017-12-01

    Efforts are underway to eliminate fetal bovine serum from mammalian cell cultures for clinical use. An emerging, viable replacement option for fetal bovine serum is human platelet lysate (PL) as either a plasma-based or serum-based product. Nine industrial-scale, serum-based PL manufacturing runs (i.e., lots) were performed, consisting of an average ± standard deviation volume of 24.6 ± 2.2 liters of pooled, platelet-rich plasma units that were obtained from apheresis donors. Manufactured lots were compared by evaluating various biochemical and functional test results. Comprehensive cytokine profiles of PL lots and product stability tests were performed. Global gene expression profiles of mesenchymal stromal cells (MSCs) cultured with plasma-based or serum-based PL were compared to MSCs cultured with fetal bovine serum. Electrolyte and protein levels were relatively consistent among all serum-based PL lots, with only slight variations in glucose and calcium levels. All nine lots were as good as or better than fetal bovine serum in expanding MSCs. Serum-based PL stored at -80°C remained stable over 2 years. Quantitative cytokine arrays showed similarities as well as dissimilarities in the proteins present in serum-based PL. Greater differences in MSC gene expression profiles were attributable to the starting cell source rather than with the use of either PL or fetal bovine serum as a culture supplement. Using a large-scale, standardized method, lot-to-lot variations were noted for industrial-scale preparations of serum-based PL products. However, all lots performed as well as or better than fetal bovine serum in supporting MSC growth. Together, these data indicate that off-the-shelf PL is a feasible substitute for fetal bovine serum in MSC cultures. © 2017 AABB.

  9. Serum phosphate and cognitive function in older men.

    PubMed

    Slinin, Yelena; Vo, Tien; Taylor, Brent C; Murray, Anne M; Schousboe, John; Langsetmo, Lisa; Ensrud, Kristine

    2018-01-01

    Determine whether serum phosphate is associated with concurrent cognitive impairment and subsequent cognitive decline in older men independent of demographic covariates and atherosclerotic risk factors. In a prospective study of 5529 men enrolled in the Osteoporotic Fractures in Men study, we measured baseline serum phosphate, baseline cognitive function, and change in cognitive function between baseline and follow-up exams an average of 4.6 years later using the Modified Mini-Mental State (3MS) Examination and Trails B. There was no association between serum phosphate and odds of cognitive impairment as assessed by baseline 3MS score or risk of cognitive decline as assessed by longitudinal change in 3MS score. Higher baseline serum phosphate was associated with higher odds of poor executive function as assessed by Trails B with fully adjusted odds ratios 1.12 (95% confidence interval: 0.83-1.52), 1.31 (0.97-1.77), and 1.45 (1.08-1.94) for men in the second, third, and fourth versus the bottom quartile (referent group) of serum phosphate (p-trend 0.007). However, higher phosphate level was not associated with risk of decline in executive function as assessed by longitudinal change in Trails B score with fully adjusted odds ratios 0.94 (95% confidence interval 0.69-1.28), 0.96 (0.70-1.32), and 1.21 (0.89-1.66) for men in the second, third, and fourth versus the bottom quartile (referent group) of serum phosphate (p-trend 0.22). Higher serum phosphate in older men was associated with a higher likelihood of poor executive function, but not with impaired global cognitive function or decline in executive or global cognition. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  10. Vitamin D and Sunlight Exposure in Newly-Diagnosed Parkinson's Disease.

    PubMed

    Wang, Juan; Yang, Deyu; Yu, Yu; Shao, Gaohai; Wang, Qunbo

    2016-03-04

    Circulating vitamin D has previously been found to be lower in patients with Parkinson's disease (PD), while the effects of sunlight exposure have not yet been fully investigated. Therefore, we evaluated the associations between serum vitamin D, vitamin D intake, sunlight exposure, and newly-diagnosed PD patients in a Chinese population. This case-control study measured serum 25-hydroxyvitamin D (25(OH)D) levels and sunlight exposure in 201 patients with newly-diagnosed PD and 199 controls without neurodegenerative diseases. Data on vitamin D intake and sunlight exposure were obtained using a self-report questionnaire. Multivariable logistic regressions were employed to evaluate the associations between serum 25(OH)D levels, sunlight exposure, and PD. Adjustments were made for sex, age, smoking, alcohol use, education, BMI, and vitamin D intake. There were significantly lower levels of serum 25(OH)D (20.6 ± 6.5 ng/mL), daily vitamin D intake (8.3 ± 3.7 g/day), and sunlight exposure (9.7 ± 4.1 h/week) in patients with PD compared to healthy controls (p < 0.05). Crude odds ratios (ORs) for PD in the quartiles of serum 25(OH)D were 1 (reference), 0.710 (0.401, 1.257), 0.631 (0.348, 1.209), and 0.483 (0.267, 0.874), respectively. Crude ORs for PD in quartiles of sunlight exposure were 1 (reference), 0.809 (0.454, 1.443), 0.623 (0.345, 1.124) and 0.533 (0.294, 0.966), respectively. A significant positive correlation between serum 25(OH)D and sunlight exposure was found, but serum 25(OH)D was not correlated with daily vitamin D intake. This study indicates that lower levels of serum 25(OH)D and sunlight exposure are significantly associated with an increased risk for PD.

  11. Effect of Transitioning from Standard Reference Material 2806a to Standard Reference Material 2806b for Light Obscuration Particle Countering

    DTIC Science & Technology

    2016-04-01

    Reference Material 2806b for Light Obscuration Particle Countering April 2016 UNCLASSIFIED UNCLASSIFIED Joel Schmitigal 27809 Standard Form 298 (Rev...Standard Reference Material 2806b for Light Obscuration Particle Countering 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6...Reference Material 2806a to Standard Reference Material 2806b for Light Obscuration Particle Countering Joel Schmitigal Force Projection

  12. Vitamin D deficiency in Europe: pandemic?12

    PubMed Central

    Dowling, Kirsten G; Škrabáková, Zuzana; Gonzalez-Gross, Marcela; Valtueña, Jara; De Henauw, Stefaan; Moreno, Luis; Damsgaard, Camilla T; Michaelsen, Kim F; Mølgaard, Christian; Jorde, Rolf; Grimnes, Guri; Moschonis, George; Mavrogianni, Christina; Manios, Yannis; Thamm, Michael; Mensink, Gert BM; Rabenberg, Martina; Busch, Markus A; Cox, Lorna; Meadows, Sarah; Goldberg, Gail; Prentice, Ann; Dekker, Jacqueline M; Nijpels, Giel; Pilz, Stefan; Swart, Karin M; van Schoor, Natasja M; Lips, Paul; Eiriksdottir, Gudny; Gudnason, Vilmundur; Cotch, Mary Frances; Koskinen, Seppo; Lamberg-Allardt, Christel; Durazo-Arvizu, Ramon A; Sempos, Christopher T; Kiely, Mairead

    2016-01-01

    Background: Vitamin D deficiency has been described as being pandemic, but serum 25-hydroxyvitamin D [25(OH)D] distribution data for the European Union are of very variable quality. The NIH-led international Vitamin D Standardization Program (VDSP) has developed protocols for standardizing existing 25(OH)D values from national health/nutrition surveys. Objective: This study applied VDSP protocols to serum 25(OH)D data from representative childhood/teenage and adult/older adult European populations, representing a sizable geographical footprint, to better quantify the prevalence of vitamin D deficiency in Europe. Design: The VDSP protocols were applied in 14 population studies [reanalysis of subsets of serum 25(OH)D in 11 studies and complete analysis of all samples from 3 studies that had not previously measured it] by using certified liquid chromatography–tandem mass spectrometry on biobanked sera. These data were combined with standardized serum 25(OH)D data from 4 previously standardized studies (for a total n = 55,844). Prevalence estimates of vitamin D deficiency [using various serum 25(OH)D thresholds] were generated on the basis of standardized 25(OH)D data. Results: An overall pooled estimate, irrespective of age group, ethnic mix, and latitude of study populations, showed that 13.0% of the 55,844 European individuals had serum 25(OH)D concentrations <30 nmol/L on average in the year, with 17.7% and 8.3% in those sampled during the extended winter (October–March) and summer (April–November) periods, respectively. According to an alternate suggested definition of vitamin D deficiency (<50 nmol/L), the prevalence was 40.4%. Dark-skinned ethnic subgroups had much higher (3- to 71-fold) prevalence of serum 25(OH)D <30 nmol/L than did white populations. Conclusions: Vitamin D deficiency is evident throughout the European population at prevalence rates that are concerning and that require action from a public health perspective. What direction these strategies take will depend on European policy but should aim to ensure vitamin D intakes that are protective against vitamin D deficiency in the majority of the European population. PMID:26864360

  13. Determination of element levels in human serum: Total reflection X-ray fluorescence applications

    NASA Astrophysics Data System (ADS)

    Majewska, U.; Łyżwa, P.; Łyżwa, K.; Banaś, D.; Kubala-Kukuś, A.; Wudarczyk-Moćko, J.; Stabrawa, I.; Braziewicz, J.; Pajek, M.; Antczak, G.; Borkowska, B.; Góźdź, S.

    2016-08-01

    Deficiency or excess of elements could disrupt proper functioning of the human body and could lead to several disorders. Determination of their concentrations in different biological human fluids and tissues should become a routine practice in medical treatment. Therefore the knowledge about appropriate element concentrations in human organism is required. The purpose of this study was to determine the concentration of several elements (P, S, Cl, K, Ca, Cr, Fe, Cu, Zn, Se, Br, Rb, Pb) in human serum and to define the reference values of element concentration. Samples of serum were obtained from 105 normal presumably healthy volunteers (66 women aged between 15 and 78 years old; 39 men aged between 15 and 77 years old). Analysis has been done for the whole studied population and for subgroups by sex and age. It is probably first so a wide study of elemental composition of serum performed in the case of Świętokrzyskie region. Total reflection X-ray fluorescence (TXRF) method was used to perform the elemental analysis. Spectrometer S2 Picofox (Bruker AXS Microanalysis GmbH) was used to identify and measure elemental composition of serum samples. Finally, 1st and 3rd quartiles were accepted as minimum and maximum values of concentration reference range.

  14. Reference values for serum levels of insulin-like growth factor 1 (IGF-1) and IGF-binding protein 3 (IGFBP-3) in the West Black Sea region of Turkey.

    PubMed

    Guven, Berrak; Can, Murat; Mungan, Gorkem; Acіkgoz, Serefden

    2013-03-01

    The aim of this study was to determine the normal values of serum IGF-1 and IGFBP-3 in Turkish children and adults (1-79 years). The study included 571 healthy children and 625 healthy adults from the West Black Sea region of Turkey. Serum IGF-1 and IGFBP-3 concentrations were determined using a chemiluminescent immunometric assay on an Immulite 1000 analyzer. IGF-1 and IGFBP-3 levels tended to be higher in girls compared to boys among the children. The differences were statistically significant in puberty from age 12-14 years for IGF-1 and prepubertally from age 9-10 years for IGFBP-3. Peaks of serum IGF-1 levels were observed 2 years earlier in girls (14 years) than boys (16 years). The general pattern of IGFBP-3 was similar to IGF-1 during puberty. In adults, IGF-1 and IGFBP-3 levels decreased by age. There was no significant difference in IGF-1 and IGFBP3 values between men and women in any age group. This study established age- and sex-specific reference values for serum IGF-1 and IGFBP-3 in healthy Turkish children and adults.

  15. Persistent low levels of serum hCG due to heterophilic mouse antibodies: an unrecognized pitfall in the diagnosis of trophoblastic disease.

    PubMed

    González Aguilera, B; Syrios, P; Gadisseur, R; Luyckx, F; Cavalier, E; Beckers, A; Valdes-Socin, H

    2016-06-01

    Phantom hCG refers to persistent mild elevations of hCG, leading physicians to unnecessary treatments whereas neither a true hCG nor a trophoblastic disease is present. We report the case of a 23-year-old woman with persistent low levels of serum hCG detected one month after miscarriage. As choriocarcinoma was suspected, a chemotherapy trial of methotrexate was prescribed, without any hCG reduction. Subsequently, laparoscopy ruled out a trophoblastic residue and the patient was referred to the Endocrine Unit for further investigations. While low levels of hCG were still detected in serum, no hCG was detected in the urine. In addition, when serum was processed in a HBT tube for revealing heterophilic antibodies, hCG was no longer detected. Such finding indicated the presence of phantom hCG due to heterophilic mouse antibodies interaction. This case raises the need of clinico-biological discussion to avoid inappropriate therapeutic decisions. Based on this case experience and after review of the literature, we suggest that current gynecological protocols for the diagnosis and treatment of trophoblastic disease should consider the inclusion of urinary hCG and/or a test for serum heterophilic antibodies when appropriate.

  16. Hypothyroidism in dogs: 66 cases (1987-1992).

    PubMed

    Panciera, D L

    1994-03-01

    Sixty-six dogs with hypothyroidism were identified from dogs examined over a 5-year period. Hypothyroidism was diagnosed only if the dog had a low, resting serum thyroxine concentration and serum thyroxine concentration was not higher than the lower limits of the reference range 6 hours after IV administration of bovine thyrotropin. The prevalence of hypothyroidism was 0.2%. Neutering was determined to be the most significant gender-associated risk factor for development of hypothyroidism. Neutered male and spayed female dogs had a higher relative risk of developing hypothyroidism than did sexually intact females. Sexually intact females had a lower relative risk. Breeds with a significantly increased risk, compared with other breeds, were the Doberman Pinscher and Golden Retriever. The most common clinical findings were obesity (41%), seborrhea (39%), alopecia (26%), weakness (21%), lethargy (20%), bradycardia (14%), and pyoderma (11%). Low voltage R-waves were found on 58% of ECG. Clinicopathologic abnormalities included hypercholesterolemia (73%), nonregenerative anemia (32%), high serum alkaline phosphatase activity (30%), and high serum creatine kinase activity (18%). Serum total triiodothyronine concentrations were within reference ranges in 15% of the hypothyroid dogs. Response to treatment was good in most dogs, but those with severe concurrent disease or neurologic abnormalities were less likely to respond with complete resolution of clinical signs.

  17. Minor changes in serum levels of cytokines after removal of amalgam restorations.

    PubMed

    Björkman, Lars; Brokstad, Karl A; Moen, Ketil; Jonsson, Roland

    2012-06-01

    Dental amalgam restorations release mercury and silver which is absorbed and distributed in the body. Animal studies have shown that both elements may interfere with the host by activation of the immune system in genetically susceptible strains at exposure levels relevant to those from dental amalgam restorations. The aim of this study was to test the hypothesis of no change over time in concentrations of a number of immune mediators in serum after removal of all dental amalgam restorations in patients with health complaints attributed to their amalgam restorations and compare with a healthy reference group. Twenty patients previously examined at a specialty unit for health complaints attributed to dental materials were included in a clinical trial and had all amalgam restorations replaced with other dental restorative materials. Serum samples were collected before amalgam removal and 3 and 12 months after the removal was finished. Twenty blood donors matched for age and gender were used as comparison group. A fluorescent bead-based (Luminex) immunoassay kit was used to measure cytokines, chemokines and growth factors in serum. At baseline, the patient group had slightly higher values for GM-CSF, IL-6, IL-2R, IFN-alpha, IL-7, and IL-12p40/p70 compared with the reference group. After amalgam removal a decrease towards the median value of the reference group was found for GM-CSF, IL-8, and IL-7. In conclusion, removal of all dental amalgam restorations and replacement with other dental restorative materials was associated with decreased concentrations of Th1-type proinflammatory markers in serum. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  18. Systematic review with meta-analysis: diagnostic performance of the combination of pepsinogen, gastrin-17 and anti-Helicobacter pylori antibodies serum assays for the diagnosis of atrophic gastritis.

    PubMed

    Zagari, R M; Rabitti, S; Greenwood, D C; Eusebi, L H; Vestito, A; Bazzoli, F

    2017-10-01

    The combination of pepsinogen, gastrin-17 and anti-H. pylori antibodies serological assays (panel test) is a non-invasive tool for the diagnosis of atrophic gastritis. However, the diagnostic reliability of this test is still uncertain. To assess the diagnostic performance of the serum panel test for the diagnosis of atrophic gastritis. Medline via PubMed, Embase, Scopus, Cochrane Library databases and abstracts of international conferences proceedings were searched from January 1995 to December 2016 using the primary keywords "pepsinogens," "gastrin," "atrophic gastritis," "gastric precancerous lesions." Studies were included if they assessed the accuracy of the serum panel test for the diagnosis of atrophic gastritis using histology according to the updated Sydney System as reference standard. Twenty studies with a total of 4241 subjects assessed the performance of serum panel test for the diagnosis of atrophic gastritis regardless of the site in the stomach. The summary sensitivity was 74.7% (95% confidence interval (CI), 62.0-84.3) and the specificity was 95.6% (95%CI, 92.6-97.4). With a prevalence of atrophic gastritis of 27% (median prevalence across the studies), the negative predictive value was 91%. Few studies with small sample size assessed the performance of the test in detecting the site of atrophic gastritis. The combination of pepsinogen, gastrin-17 and anti-H. pylori antibodies serological assays appears to be a reliable tool for the diagnosis of atrophic gastritis. This test may be used for screening subjects or populations at high risk of gastric cancer for atrophic gastritis; however, a cost-effectiveness analysis is needed. © 2017 John Wiley & Sons Ltd.

  19. A new dispersive liquid-liquid microextraction using ionic liquid based microemulsion coupled with cloud point extraction for determination of copper in serum and water samples.

    PubMed

    Arain, Salma Aslam; Kazi, Tasneem Gul; Afridi, Hassan Imran; Arain, Mariam Shahzadi; Panhwar, Abdul Haleem; Khan, Naeemullah; Baig, Jameel Ahmed; Shah, Faheem

    2016-04-01

    A simple and rapid dispersive liquid-liquid microextraction procedure based on ionic liquid assisted microemulsion (IL-µE-DLLME) combined with cloud point extraction has been developed for preconcentration copper (Cu(2+)) in drinking water and serum samples of adolescent female hepatitits C (HCV) patients. In this method a ternary system was developed to form microemulsion (µE) by phase inversion method (PIM), using ionic liquid, 1-butyl-3-methylimidazolium hexafluorophosphate ([C4mim][PF6]) and nonionic surfactant, TX-100 (as a stabilizer in aqueous media). The Ionic liquid microemulsion (IL-µE) was evaluated through visual assessment, optical light microscope and spectrophotometrically. The Cu(2+) in real water and aqueous acid digested serum samples were complexed with 8-hydroxyquinoline (oxine) and extracted into IL-µE medium. The phase separation of stable IL-µE was carried out by the micellar cloud point extraction approach. The influence of of different parameters such as pH, oxine concentration, centrifugation time and rate were investigated. At optimized experimental conditions, the limit of detection and enhancement factor were found to be 0.132 µg/L and 70 respectively, with relative standard deviation <5%. In order to validate the developed method, certified reference materials (SLRS-4 Riverine water) and human serum (Sero-M10181) were analyzed. The resulting data indicated a non-significant difference in obtained and certified values of Cu(2+). The developed procedure was successfully applied for the preconcentration and determination of trace levels of Cu(2+) in environmental and biological samples. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Nucleic Acid-Based Cross-Linking Assay for Detection and Quantification of Hepatitis B Virus DNA

    PubMed Central

    Lai, Vicky C. H.; Guan, Richard; Wood, Michael L.; Lo, Su Kong; Yuen, Man-Fung; Lai, Ching-Lung

    1999-01-01

    A nucleic acid photo-cross-linking technology was used to develop a direct assay for the quantification of hepatitis B virus (HBV) DNA levels in serum. Cross-linker-modified DNA probes complementary to the viral genomes of the major HBV subtypes were synthesized and used in an assay that could be completed in less than 6 h. The quantification range of the assay, as determined by testing serial dilutions of Eurohep HBV reference standards and cloned HBV DNA, was 5 × 105 to 3 × 109 molecules of HBV DNA/ml of serum. Within-run and between-run coefficients of variation (CVs) for the assay were 4.3 and 4.0%, respectively. The assay was used to determine HBV DNA levels in 302 serum samples, and the results were compared to those obtained after testing the same samples with the Chiron branched-DNA (bDNA) assay for HBV DNA. Of the samples tested, 218 were positive for HBV DNA by both assays and 72 gave results below the cutoff for both assays. Of the remaining 12 samples, 10 were positive for HBV DNA by the cross-linking assay only; the 2 other samples were positive by the bDNA assay only. Twenty-eight samples had to be retested by the bDNA assay (CV, >20% between the results obtained from the testing of each sample in duplicate), whereas only three samples required retesting by the cross-linking assay. The correlation between the HBV DNA levels, as measured by the two tests, was very high (r = 0.902; P = 0.01). We conclude that the cross-linking assay is a sensitive and reproducible method for the detection and quantification of HBV DNA levels in serum. PMID:9854083

  1. Males with low serum levels of vitamin D have lower pregnancy rates when ovulation induction and timed intercourse are used as a treatment for infertile couples: results from a pilot study.

    PubMed

    Tartagni, Massimo; Matteo, Maria; Baldini, Domenico; Tartagni, Mario V; Alrasheed, Hala; De Salvia, Maria A; Loverro, Giuseppe; Montagnani, Monica

    2015-11-21

    Vitamin D (Vit D) is important for the regulation of reproductive physiology. In humans, maternal Vit D deficiency has been implicated in several reproductive- and pregnancy-related disorders. Very few data are available regarding the Vit D status in male partners of couples attempting pregnancy. This observational study (IRB Prot. N. 078/13) aimed to evaluate whether low Vit D serum levels in males might decrease the rate of successful conception in couples attempting pregnancy. Male and female partners of infertile couples (n = 102) were classified into 2 GROUPS according to normal (≥30 ng/ml) or low (below 30 ng/ml) serum Vit D levels in male partners. Semen analysis was performed in each male participant based on the WHO reference criteria. The female partners of both groups were subjected to 3 consecutive cycles of gonadotropin-induced mono-ovulation. The main outcome measures included the clinical pregnancy rate, delivery per patient and per cycle, and miscarriage rate between the 2 groups evaluated at the end of the three-month period of the study. In male partners of both groups, standard semen analysis did not highlight substantial differences in sperm concentration, sperm progressive motility, or typical form. The pregnancy rates per patient and per cycle and delivery rates per patient and per cycle were all significantly higher (p< 0.05) in couples with normal Vit D levels. These results suggest the existence of a relationship between male Vit D serum levels and semen ability to begin a pregnancy during cycles of timed vaginal intercourse.

  2. Diagnostic reference range of κ/λ free light chain ratio to screen for Bence Jones proteinuria is not significantly influenced by GFR.

    PubMed

    Schmidt-Hieltjes, Yvonne; Elshof, Clemens; Roovers, Lian; Ruinemans-Koerts, Janneke

    2016-05-01

    The aim of our study was to analyse whether the κ/λ free light chain ratio reference range for screening for Bence Jones proteinuria should be dependent on the estimated glomerular filtration rate (eGFR). The serum κ/λ free light chain ratio, eGFR, serum M-protein and Bence Jones protein were measured in 544 patients for whom Bence Jones protein analysis was ordered. In the population of patients without Bence Jones proteinuria or a M-protein (n = 402), there is no gradual increase in κ/λ free light chain ratio with diminishing eGFR. The κ/λ free light chain ratio in this group was 0.56-1.86 (95% interval). With this diagnostic reference range of the κ/λ ratio, 105 of the 110 patients with Bence Jones protein could be identified correctly. Only five patients with Bence Jones proteinuria (<0.17 g/L) were missed, without diagnostic or therapeutic consequences. In 36 patients (6.6%), an abnormal κ/λ free light chain ratio was measured without the presence of Bence Jones proteinuria. A κ/λ free light chain ratio in serum can be used safely and efficiently to select urine samples which should be analysed for Bence Jones proteinuria with an electrophoresis/immunofixation technique. Using this diagnostic reference range, the number of urine samples which should be analysed by electrophoresis/immunofixation could be reduced by 74%. The diagnostic reference interval can be determined best in a group of patients for whom Bence Jones analysis is indicated. For calculation of this reference range, the eGFR value does not need to be taken into account. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Establishing pediatric reference intervals for 13 biochemical analytes derived from normal subjects in a pediatric endocrinology clinic in Korea.

    PubMed

    Cho, Sun-Mi; Lee, Sang-Guk; Kim, Ho Seong; Kim, Jeong-Ho

    2014-12-01

    Defining pediatric reference intervals is one of the most difficult tasks for laboratory physicians. The continuously changing physiology of growing children makes their laboratory values moving targets. In addition, ethnic and behavioral differences might also cause variations. The aim of this study was to establish age- and sex-specific partitioned reference intervals for 13 serum biochemical analytes in Korean children. A total of 2474 patients, girls aged 2-14 years and boys aged 2-16 years, who underwent a short stature workup but were diagnosed as normal at the Pediatric Endocrinology Clinic of Severance Hospital (Seoul, Korea) between September 2010 and June 2012 were included in this study. The levels of serum calcium, inorganic phosphorus, blood urea nitrogen, creatinine, uric acid, glucose, total cholesterol, total protein, albumin, alkaline phosphatase, aspartic aminotransferase, alanine aminotransferase, and total bilirubin were measured using a Hitachi 7600 analyzer (Hitachi High-Technologies Corporation, Tokyo, Japan). Reference intervals were partitioned according to sex or age subgroups using the Harris and Boyd method. Most analytes except calcium and albumin required partitioning either by sex or age. Age-specific partitioned reference intervals for alkaline phosphatase, creatinine, and total bilirubin were established for both males and females after being partitioned by sex. Additional age-specific partitioning of aspartic aminotransferase in females and total protein and uric acid in males was also required. Inorganic phosphorus, total cholesterol, alanine aminotransferase, blood urea nitrogen, and glucose were partitioned only by sex. This study provided updated age- and sex-specific pediatric reference intervals for 13 basic serum chemistry analytes from a sufficient number of healthy children by using a modern analytical chemistry platform. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  4. Thyroid Stimulating Hormone Reference Range and Prevalence of Thyroid Dysfunction in the Korean Population: Korea National Health and Nutrition Examination Survey 2013 to 2015

    PubMed Central

    2017-01-01

    Background No nationwide epidemiological study evaluating the prevalence of subclinical and overt forms of hypothyroidism and hyperthyroidism has yet been conducted in Korea. This study aimed to evaluate the reference range of serum thyroid stimulating hormone (TSH) and the national prevalence of thyroid dysfunctions in Korea. Methods Nation-wide cross-sectional data were analyzed from a representative sample of the civilian, non-institutionalized Korean population (n=6,564) who underwent blood testing for thyroid function and anti-thyroid peroxidase antibody (TPOAb) as part of the Korea National Health and Nutrition Examination Survey VI (2013 to 2015). Results The reference interval of serum TSH in the Korean reference population was 0.62 to 6.68 mIU/L. Based on this reference interval, the prevalence of overt and subclinical hypothyroidism was 0.73% (males 0.40%, females 1.10%) and 3.10% (males 2.26%, females 4.04%), respectively. The prevalence of hypothyroidism increased with age until the age group between 50 to 59 years. Positive TPOAb were found in 7.30% of subjects (males 4.33%, females 10.62%). The prevalence of overt and subclinical hypothyroidism TPOAb-positive subjects was 5.16% and 10.88%, respectively. The prevalence of overt and subclinical hyperthyroidism was 0.54% (males 0.30%, females 0.81%) and 2.98% (males 2.43%, females, 3.59%), respectively. Conclusion The Serum TSH reference levels in the Korean population were higher than the corresponding levels in Western countries. Differences were found in the prevalence of hypothyroidism and hyperthyroidism according to age, sex, and TPOAb positivity. This study provides important baseline information for understanding patterns of thyroid dysfunction and diseases in Korea. PMID:28116874

  5. Optimized angiotensin-converting enzyme activity assay for the accurate diagnosis of sarcoidosis.

    PubMed

    Csongrádi, Alexandra; Enyedi, Attila; Takács, István; Végh, Tamás; Mányiné, Ivetta S; Pólik, Zsófia; Altorjay, István Tibor; Balla, József; Balla, György; Édes, István; Kappelmayer, János; Tóth, Attila; Papp, Zoltán; Fagyas, Miklós

    2018-06-27

    Serum angiotensin-converting enzyme (ACE) activity determination can aid the early diagnosis of sarcoidosis. We aimed to optimize a fluorescent kinetic assay for ACE activity by screening the confounding effects of endogenous ACE inhibitors and interfering factors. Genotype-dependent and genotype-independent reference values of ACE activity were established, and their diagnostic accuracies were validated in a clinical study. Internally quenched fluorescent substrate, Abz-FRK(Dnp)P-OH was used for ACE-activity measurements. A total of 201 healthy individuals and 59 presumably sarcoidotic patients were enrolled into this study. ACE activity and insertion/deletion (I/D) genotype of the ACE gene were determined. Here we report that serum samples should be diluted at least 35-fold to eliminate the endogenous inhibitor effect of albumin. No significant interferences were detected: up to a triglyceride concentration of 16 mM, a hemoglobin concentration of 0.71 g/L and a bilirubin concentration of 150 μM. Genotype-dependent reference intervals were considered as 3.76-11.25 U/L, 5.22-11.59 U/L, 7.19-14.84 U/L for II, ID and DD genotypes, respectively. I/D genotype-independent reference interval was established as 4.85-13.79 U/L. An ACE activity value was considered positive for sarcoidosis when it exceeded the upper limit of the reference interval. The optimized assay with genotype-dependent reference ranges resulted in 42.5% sensitivity, 100% specificity, 100% positive predictive value and 32.4% negative predictive value in the clinical study, whereas the genotype-independent reference range proved to have inferior diagnostic efficiency. An optimized fluorescent kinetic assay of serum ACE activity combined with ACE I/D genotype determination is an alternative to invasive biopsy for confirming the diagnosis of sarcoidosis in a significant percentage of patients.

  6. [Clinical evaluation of a novel HBsAg quantitative assay].

    PubMed

    Takagi, Kazumi; Tanaka, Yasuhito; Naganuma, Hatsue; Hiramatsu, Kumiko; Iida, Takayasu; Takasaka, Yoshimitsu; Mizokami, Masashi

    2007-07-01

    The clinical implication of the hepatitis B surface antigen (HBsAg) concentrations in HBV-infected individuals remains unclear. The aim of this study was to evaluate a novel fully automated Chemiluminescence Enzyme Immunoassay (Sysmex HBsAg quantitative assay) by comparative measurements of the reference serum samples versus two independent commercial assays (Lumipulse f or Architect HBsAg QT). Furthermore, clinical usefulness was assessed for monitoring of the serum HBsAg levels during antiviral therapy. A dilution test using 5 reference-serum samples showed linear correlation curve in range from 0.03 to 2,360 IU/ml. The HBsAg was measured in total of 400 serum samples and 99.8% had consistent results between Sysmex and Lumipulse f. Additionally, a positive linear correlation was observed between Sysmex and Architect. To compare the Architect and Sysmex, both methods were applied to quantify the HBsAg in serum samples with different HBV genotypes/subgenotypes, as well as in serum contained HBV vaccine escape mutants (126S, 145R). Correlation between the methods was observed in results for escape mutants and common genotypes (A, B, C) in Japan. Observed during lamivudine therapy, an increase in HBsAg and HBV DNA concentrations preceded the aminotransferase (ALT) elevation associated with drug-resistant HBV variant emergence (breakthrough hepatitis). In conclusion, reliability of the Sysmex HBsAg quantitative assay was confirmed for all HBV genetic variants common in Japan. Monitoring of serum HBsAg concentrations in addition to HBV DNA quantification, is helpful in evaluation of the response to lamivudine treatment and diagnosis of the breakthrough hepatitis.

  7. Determination of antibacterial flomoxef in serum by capillary electrophoresis.

    PubMed

    Kitahashi, Toshihiro; Furuta, Itaru

    2003-04-01

    A determination method of flomoxef (FMOX) concentration in serum by capillary electrophoresis is developed. Serum samples are extracted with acetonitrile. After pretreatment, they are separated in a fused-silica capillary tube with a 25 mM borate buffer (pH 10.0) as a running buffer that contains 50mM sodium dodecyl sulfate. The FMOX and acetaminophen (internal standard) are detected by UV absorbance at 200 nm. Linearity (0-200 mg/L) is good, and the minimum limit of detection is 1.0 mg/L (S/N = 3). The relative standard deviations of intra- and interassay variability are 1.60-4.78% and 2.10-3.31%, respectively, and the recovery rate is 84-98%. This method can be used for determination of FMOX concentration in serum.

  8. Evaluation of serological diagnostic tests for typhoid fever in Papua New Guinea using a composite reference standard.

    PubMed

    Siba, Valentine; Horwood, Paul F; Vanuga, Kilagi; Wapling, Johanna; Sehuko, Rebecca; Siba, Peter M; Greenhill, Andrew R

    2012-11-01

    Typhoid fever remains a major global health problem. A major impediment to improving outcomes is the lack of appropriate diagnostic tools, which have not significantly improved in low-income settings for 100 years. We evaluated two commercially available rapid diagnostic tests (Tubex and TyphiDot), a prototype (TyphiRapid TR-02), and the commonly used single-serum Widal test in a previously reported high-burden area of Papua New Guinea. Samples were collected from 530 outpatients with axillary temperatures of ≥37.5°C, and analysis was conducted on all malaria-negative samples (n = 500). A composite reference standard of blood culture and PCR was used, by which 47 participants (9.4%) were considered typhoid fever positive. The sensitivity and specificity of the Tubex (51.1% and 88.3%, respectively) and TyphiDot (70.0% and 80.1%, respectively) tests were not high enough to warrant their ongoing use in this setting; however, the sensitivity and specificity for the TR-02 prototype were promising (89.4% and 85.0%, respectively). An axillary temperature of ≥38.5°C correlated with typhoid fever (P = 0.014). With an appropriate diagnostic test, conducting typhoid fever diagnosis only on patients with high-grade fever could dramatically decrease the costs associated with diagnosis while having no detrimental impact on the ability to accurately diagnose the illness.

  9. Preparation of peanut butter suspension for determination of peanuts using enzyme-linked immunoassay kits.

    PubMed

    Trucksess, Mary W; Brewer, Vickery A; Williams, Kristina M; Westphal, Carmen D; Heeres, James T

    2004-01-01

    Peanuts are one of the 8 most common allergenic foods and a large proportion of peanut-allergic individuals have severe reactions, some to minimal exposure. Specific protein constituents in the peanuts are the cause of the allergic reactions in sensitized individuals who ingest the peanuts. To avoid accidental ingestion of peanut-contaminated food, methods of analysis for the determination of the allergenic proteins in foods are important tools. Such methods could help identify foods inadvertently contaminated with peanuts, thereby reducing the incidence of allergic reactions to peanuts. Commercial immunoassay kits are available but need study for method performance, which requires reference materials for within- and between-laboratory validations. In this study, National Institute of Standards and Technology Standard Reference Material 2387 peanut butter was used. A polytron homogenizer was used to prepare a homogenous aqueous Peanut Butter suspension for the evaluation of method performance of some commercially available immunoassay kits such as Veratox for Peanut Allergen Test (Neogen Corp.), Ridascreen Peanut (R-Biopharm GmbH), and Bio-Kit Peanut Protein Assay Kit (Tepnel). Each gram of the aqueous peanut butter suspension contained 20 mg carboxymethylcellulose sodium salt, 643 microg peanut, 0.5 mg thimerosal, and 2.5 mg bovine serum albumin. The suspension was homogenous, stable, reproducible, and applicable for adding to ice cream, cookies, breakfast cereals, and chocolate for recovery studies at spike levels ranging from 12 to 90 microg/g.

  10. Deceiving proteins! A case of lymphoma and high creatinine.

    PubMed

    Metraiah, El Hakem Abdelkarim; Regan, Helen; Louw, Johanna; Kidder, Dana

    2017-01-23

    Estimation of kidney function by measuring serum creatinine is one the commonest laboratory tests conducted in clinical practice. Enzymatic methods are often used to measure serum creatinine. Clinicians should be aware of the limitations of these methods, such as test interference with paraproteins.We present a case of falsely elevated serum creatinine in a patient referred for renal biopsy. The combination of fluctuating creatinine and normal blood urea level was unusual. Serum protein electrophoresis revealed the presence of an IgM paraprotein. Further investigations confirmed an underlying diagnosis of lymphoplasmacytoid lymphoma. This case highlights how IgM paraprotein can interfere with creatinine estimation by enzymatic assay and the utility of alternative methods of estimating serum creatinine. 2017 BMJ Publishing Group Ltd.

  11. Determination of serum bactericidal activity against Escherichia coli by an automated photometric method.

    PubMed Central

    Crokaert, F; Lismont, M J; van der Linden, M P; Yourassowsky, E

    1988-01-01

    The resistance of gram-negative bacteria to complement-mediated serum activity is supposedly an important virulence factor. However, the lack of standardization in the methods used to determine serum activity and the many definitions applied make the comparisons between studies very difficult. We developed a rapid photometric method that we compared with a classical killing one. Escherichia coli in the exponential phase of growth in brain heart infusion broth (final inoculum, 10(7) CFU/ml) at 35 degrees C was added to 50% human serum in Veronal buffer. Viable counts and automatic recording of the variations in the optical densities were obtained for 40 E. coli strains isolated from the stools of healthy adults. With the viable count method, 17 (42.5%) were susceptible (at least a 1 log CFU/ml decrease), 17 (42.5%) were resistant (a 0.6 log CFU/ml increase), 4 (10%) were intermediate (poorly growing inoculum or a decrease of less than 1 log CFU/ml), and 2 could not be classified (nonreproducible results). Agreement between both methods was observed for 87.5% of the stool strains. Eight reference strains of known susceptibilities were classified identically by both methods, leading to a final concordance rate of 89.6%. A total of 129 blood isolates were tested by the photometric method: 64 (49.6%) were resistant, 50 (38.8%) were susceptible 5 (3.9%) showed early regrowth, and 10 (7.7%) were not perfectly reproducible. Of these 129 blood isolates, 5 were also tested by the killing method: 37 (49%) were resistant, 32 (43%) were susceptible, and 6 (8%) were intermediate. The concordance rate between both assays was 89% for the blood isolates; when the minor discordances were ruled out, it was 97%. This automated method could be a useful screening tool for detecting resistance to serum in clinical trials and for studying the in vitro variations of this property. PMID:3053761

  12. Measurements in international units of antibody to hepatitis B surface antigen(anti-HBs) after immunization with a yeast-derived, subtype adr hepatitis B vaccine are considerably different between chemiluminescent immunoassay (CLIA) and chemiluminescent enzyme immunoassay (CLEIA).

    PubMed

    Ogata, Norio

    2006-04-01

    The worldwide consensus of the minimum protective anti-HBs level against HBV infection is 10 mIU/mL on assays standardized by the World Health Organization (WHO) reference preparations. To investigate whether this value could be applied to recipients of yeast-derived recombinant HB vaccine containing the major surface protein of subtype adr (Bimmugen, Astellas Pharmaceutical, Tokyo), we compared anti-HBs measurements between chemiluminescent immunoassay (CLIA) (Architect Ausab, Abbott Japan, Tokyo) and chemiluminescent enzyme immunoassay (CLEIA) (Lumipulse Forte, Fujirebio, Tokyo) in given serum samples obtained from the vaccinees. The vaccine and the two assay methods are currently in a wide use in Japan. The study included 300 medical students who completed a standard vaccination course (0, 1 and 6 months). Serum samples obtained 1 month or 13 months after completing the vaccination were simultaneously tested for anti-HBs by CLIA and CLEIA. In 147 samples with quantifiable values on both CLIA and CLEIA (10 to 1000 mIU/mL) the geometric mean titer on CLEIA (225.0 mIU/mL) was significantly higher than that on CLIA (94.5 mIU/mL) (p < 0.0001). Of 26 subjects with CLIA measurements below 10 mIU/mL, 15 samples (57.7%) showed CLEIA measurements more than 10 mIU/mL. Thus, in the subtype adr-vaccinees CLEIA demonstrated considerably high serum anti-HBs measurements compared to CLIA and discordance in determining critical anti-HBs level of 10 mIU/mL was observed in more than half the samples. This suggests that the minimum HBV-protective anti HBs titer of 10 mIU/mL is difficult to be introduced to Japan where subtype adr-HB vaccines or -HBV infection are prevalent, unless characteristics of assay methods are carefully evaluated.

  13. Evaluation of bilirubin interference and accuracy of six creatinine assays compared with isotope dilution-liquid chromatography mass spectrometry.

    PubMed

    Nah, Hyunjin; Lee, Sang-Guk; Lee, Kyeong-Seob; Won, Jae-Hee; Kim, Hyun Ok; Kim, Jeong-Ho

    2016-02-01

    The aim of this study was to estimate bilirubin interference and accuracy of six routine methods for measuring creatinine compared with isotope dilution-liquid chromatography mass spectrometry (ID-LC/MS). A total of 40 clinical serum samples from 31 patients with serum total bilirubin concentration >68.4μmol/L were collected. Serum creatinine was measured using two enzymatic reagents and four Jaffe reagents as well as ID-LC/MS. Correlations between bilirubin concentration and percent difference in creatinine compared with ID-LC/MS were analyzed to investigate bilirubin interference. Bias estimations between the six reagents and ID-LC/MS were performed. Recovery tests using National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) 967a were also performed. Both the enzymatic methods showed no bilirubin interference. However, three of the four Jaffe methods demonstrated significant bilirubin concentration-dependent interference in samples with creatinine levels <53μmol/L, and two of them showed significant bilirubin interference in samples with creatinine levels ranging from 53.0 to 97.2μmol/L. Comparison of these methods with ID-LC/MS using patients' samples with elevated bilirubin revealed that the tested methods failed to achieve the bias goal at especially low levels of creatinine. In addition, recovery test using NIST SRM 967a showed that bias in one Jaffe method and two enzymatic methods did not achieve the bias goal at either low or high level of creatinine, indicating they had calibration bias. One enzymatic method failed to achieve all the bias goals in both comparison experiment and recovery test. It is important to understand that both bilirubin interference and calibration traceability to ID-LC/MS should be considered to improve the accuracy of creatinine measurement. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  14. Impact of a product-specific reference standard for the measurement of a PEGylated rFVIII activity: the Swiss Multicentre Field Study.

    PubMed

    Bulla, O; Poncet, A; Alberio, L; Asmis, L M; Gähler, A; Graf, L; Nagler, M; Studt, J-D; Tsakiris, D A; Fontana, P

    2017-07-01

    Measuring factor VIII (FVIII) activity can be challenging when it has been modified, such as when FVIII is pegylated to increase its circulating half-life. Use of a product-specific reference standard may help avoid this issue. Evaluate the impact of using a product-specific reference standard for measuring the FVIII activity of BAX 855 - a pegylated FVIII - in eight of Switzerland's main laboratories. Factor VIII-deficient plasma, spiked with five different concentrations of BAX 855, plus a control FVIII sample, was sent to the participating laboratories. They measured FVIII activity by using either with a one-stage (OSA) or the chromogenic assay (CA) against their local or a product-specific reference standard. When using a local reference standard, there was an overestimation of BAX 855 activity compared to the target concentrations, both with the OSA and CA. The use of a product-specific reference standard reduced this effect: mean recovery ranged from 127.7% to 213.5% using the OSA with local reference standards, compared to 110% to 183.8% with a product-specific reference standard, and from 146.3% to 182.4% using the CA with local reference standards compared to 72.7% to 103.7% with a product-specific reference standard. In this in vitro study, the type of reference standard had a major impact on the measurement of BAX 855 activity. Evaluation was more accurate and precise when using a product-specific reference standard. © 2017 John Wiley & Sons Ltd.

  15. Assessment of tolerant sunfish populations (Lepomis sp.) inhabiting selenium-laden coal ash effluents. 3. Serum chemistry and fish health indicators.

    PubMed

    Lohner, T W; Reash, R J; Willet, V E; Fletcher, J

    2001-11-01

    Sunfish were collected from fly ash discharge-receiving streams to assess the possible effects of exposure to elevated selenium. Concentrations of selenium, copper, and arsenic were statistically higher in fish tissue (liver) samples from effluent-exposed fish than in reference fish. Several biomarkers were indicative of metal exposure and effect. Plasma protein levels and cholesterol levels were significantly lower in exposed fish, indicating nutritional stress. Ion levels (i.e., K) increased with exposure to ash pond metals, indicating possible gill damage. Fish from the receiving streams also had increased serum glucose and osmolality indicating possible acute stress due to sampling. Fish health assessments revealed a lower incidence of fin erosion, kidney discoloration, urolithiasis or nephrocalcinosis, liver discoloration, and parasites in exposed fish and a higher incidence of skin, eye, and gill aberrations. Condition factors of exposed fish were correlated with biomarker response and were the same as or lower than those of reference fish, but not related to selenium levels. Although several serum biochemical indicators differed between the ash pond-receiving stream and reference sites, pollutant exposure was apparently not sufficient to cause functional damage to critical organ systems.

  16. High prevalence of fastidious bacteria in 1520 cases of uveitis of unknown etiology.

    PubMed

    Drancourt, Michel; Berger, Pierre; Terrada, Céline; Bodaghi, Bahram; Conrath, John; Raoult, Didier; LeHoang, Phuc

    2008-05-01

    The etiologic evaluation of uveitis is frequently unsuccessful when noninvasive methods are used. We conducted a prospective study to evaluate systematic screening for pathogens of uveitis. All patients with uveitis referred to the participating tertiary ophthalmology departments from January 2001 to September 2007 underwent intraocular and serum specimen collection. The standardized protocol for laboratory investigations included universal polymerase chain reaction (PCR)-based detection of any bacteria and mycoses, specific PCR-based detection of fastidious (difficult-to-grow) bacteria and herpes viruses, and culture of vitreous fluid. Sera were tested for fastidious bacteria. Among the 1321 included patients (1520 specimens), infection was diagnosed in 147 (11.1%) patients: 78 (53%) were caused by fastidious bacteria that included spirochetes, Bartonella species, intracellular bacteria (Chlamydia species, Rickettsia species, Coxiella burnetii), and Tropheryma whipplei; 18 by herpes viruses; and 9 by fungi. Bartonella quintana, Coxiella burnetii, Paracoccus yeei, Aspergillus oryzae, and Cryptococcus albidus were found to be associated with uveitis for the first time, to our knowledge. We recommend applying a 1-step diagnostic procedure that incorporates intraocular, specific microbial PCR with serum analyses in tertiary centers to determine the etiology of uveitis.

  17. [The subject matters concerned with use of simplified analytical systems from the perspective of the Japanese Association of Medical Technologists].

    PubMed

    Morishita, Y

    2001-05-01

    The subject matters concerned with use of so-called simplified analytical systems for the purpose of useful utilizing are mentioned from the perspective of a laboratory technician. 1. The data from simplified analytical systems should to be agreed with those of particular reference methods not to occur the discrepancy of the data from different laboratories. 2. Accuracy of the measured results using simplified analytical systems is hard to be scrutinized thoroughly and correctly with the quality control surveillance procedure on the stored pooled serum or partly-processed blood. 3. It is necessary to present the guide line to follow about the contents of evaluation to guarantee on quality of simplified analytical systems. 4. Maintenance and manual performance of simplified analytical systems have to be standardized by a laboratory technician and a selling agent technician. 5. It calls attention, further that the cost of simplified analytical systems is much expensive compared to that of routine method with liquid reagents. 6. Various substances in human serum, like cytokine, hormone, tumor marker, and vitamin, etc. are also hoped to be measured by simplified analytical systems.

  18. [Determination of ferulic acid absorbed into human serum from oral decoction of rhizoma chuanxiong and pharmacokinetic study of ferulic acid].

    PubMed

    Sun, S; Huang, X; Zhang, L; Ren, P; Chang, Z

    2001-10-01

    To improve the HPLC method for determining ferulic acid(FA) in the human serum and to research FA clinical pharmacokinetics. Serum concentrations of FA were determined by HPLC using methanol-water-acetic acid (40:59.7:0.3, v/v) as the mobile phase and the column packed with ODS (150 mm x 4.6 mm, 5 microns) as a fixed phase and the flow rate was 1.0 ml/min. FA was detected at 320 nm wave length. The internal standard was coumarin. The serum samples were treated by the water-boiling method. Peak of FA in serum was recognized by photodiode-array detection. FA and internal standard were separated completely under the condition described as above. FA was linear in the range of (40.16-8032 ng/ml) (r = 0.9975). The CV was less than 10%, the average recovery was 100.3%, and the limit concentration in serum was 25.1 ng/ml. PK was in accordance with open bicameral model. This method can be applied to clinical pharmacokinetic study of FA.

  19. Immunogenicity of an interferon-beta1a product.

    PubMed

    Kauffman, M A; Sterin-Prync, A; Papouchado, M; González, E; Vidal, A J; Grossberg, S E; Chuppa, S; Odoriz, B; Vrech, C; Diez, R A; Ferro, H H

    2011-01-01

    In order to determine whether Blastoferon®, a biosimilar interferon (IFN)- beta 1a formulation, shares epitopes with other known IFN-beta products, a series of neutralization bioassays were performed with a set of well-characterized anti-IFN- beta monoclonal antibodies and human sera (World Health Organization Reference Reagents). The bioassay was the interferon-induced inhibition of virus cytopathic effect on human cells in culture (EMC virus and A-549 cells). Computer-calculated results were reported as Tenfold Reduction Units (TRU)/ml. To further assess Blastoferon® immunogenicity, in vivo production of anti-IFN beta antibodies was determined in sera of patients included in the pharmacovigilance plan of Blastoferon® by the level of IFN- beta 1a binding antibodies (by enzyme immunoassay -EIA) and neutralizing antibodies (in the Wish-VSV system). The highly characterized neutralizing monoclonal antibodies A1 and A5 that bind to specific regions of the IFN- beta molecule reacted positively with the three beta 1a IFNs: Blastoferon®, Rebif®, and the IFN- beta WHO Second International Standard 00/572. As expected, the non-neutralizing monoclonal antibodies B4 and B7 did not neutralize any of the IFN- beta preparations. The commercially available monoclonal antibody B-02 reacted essentially equally with Rebif® and Blastoferon®. The WHO Reference Reagent human serum anti-IFN- beta polyclonal antibody neutralized all the IFN- beta products, whereas the WHO Reference Reagent human serum anti-IFN-alpha polyclonal antibody G037-501-572 appropriately failed to react with any of the IFN- beta products. On the basis of in vitro reactivity with known, well-characterized monoclonal and polyclonal antibody preparations, Blastoferon® shares immunological determinants with other human interferon- beta products, especially IFN- beta 1a. In vivo antibodies were detected by EIA in 72.9% of 37 chronically treated multiple sclerosis patients, whereas neutralizing antibodies were found in 8.1% of them. Blastoferon® appears to have immunological characteristics comparable to other IFN- beta 1a products.

  20. Clinical and Biochemical Correlates of Serum L-Ergothioneine Concentrations in Community-Dwelling Middle-Aged and Older Adults

    PubMed Central

    Sotgia, Salvatore; Zinellu, Angelo; Mangoni, Arduino A.; Pintus, Gianfranco; Attia, John; Carru, Ciriaco; McEvoy, Mark

    2014-01-01

    Background Despite the increasing interest towards the biological role of L-ergothioneine, little is known about the serum concentrations of this unusual aminothiol in older adults. We addressed this issue in a representative sample of community-dwelling middle-aged and older adults. Methods Body mass index, estimated glomerular filtration rate, serum concentrations of L-ergothioneine, taurine, homocysteine, cysteine, glutathione, cysteinylglycine, and glutamylcysteine were evaluated in 439 subjects (age 55–85 years) randomly selected from the Hunter Community Study. Results Median L-ergothioneine concentration in the entire cohort was 1.01 IQR 0.78–1.33 µmol/L. Concentrations were not affected by gender (P = 0.41) or by presence of chronic medical conditions (P = 0.15). By considering only healthy subjects, we defined a reference interval for L-ergothioneine serum concentrations from 0.36 (90% CI 0.31–0.44) to 3.08 (90% CI 2.45–3.76) µmol/L. Using stepwise multiple linear regression analysis L-ergothioneine was negatively correlated with age (rpartial = −0.15; P = 0.0018) and with glutamylcysteine concentrations (rpartial = −0.13; P = 0.0063). Conclusions A thorough analysis of serum L-ergothioneine concentrations was performed in a large group of community-dwelling middle-aged and older adults. Reference intervals were established. Age and glutamylcysteine were independently negatively associated with L-ergothioneine serum concentration. PMID:24392160

  1. Biobanking of different body fluids within the frame of IVF-a standard operating procedure to improve reproductive biology research.

    PubMed

    Schenk, Michael; Huppertz, Berthold; Obermayer-Pietsch, Barbara; Kastelic, Darja; Hörmann-Kröpfl, Martina; Weiss, Gregor

    2017-02-01

    The aim of the present study was to develop a standard operating procedure (SOP) for the collection, transport, and storage of human cumulus cells, follicular fluid, blood serum, seminal plasma, embryo culture supernatant, and embryo culture supernatant control obtained within the IVF process under approved protocols and written informed consent from participating patients. The SOP was developed at the Kinderwunsch Institut Schenk, Dobl, Austria, together with Biobank Graz of the Medical University of Graz, Austria. The SOP provides comprehensive details of laboratory procedures and sampling of the different fluids within the IVF process. Furthermore, information on sample coding, references of involved laboratory techniques (e.g., oocyte retrieval with a Steiner-TAN needle), ethical approvals, and biobanking procedures are presented. The result of the present study is a standard operating procedure. The SOP ensures a professional way for collection and scientific use of IVF samples by the Kinderwunsch Institut Schenk, Dobl, Austria, and Biobank Graz of the Medical University of Graz, Austria. It can be used as a template for other institutions to unify specimen collection procedures in the field of reproductive health research.

  2. Association of high fetuin-B concentrations in serum with fertilization rate in IVF: a cross-sectional pilot study.

    PubMed

    Floehr, Julia; Dietzel, Eileen; Neulen, Josef; Rösing, Benjamin; Weissenborn, Ute; Jahnen-Dechent, Willi

    2016-03-01

    Is serum fetuin-B associated with the fertilization rate in in vitro fertilization (IVF)? Serum fetuin-B increased during IVF cycles when oocytes could be fertilized while remained unchanged in fertilization failure. Fetuin-B deficiency in mice causes premature zona pellucida hardening mediated by the zona protease ovastacin. Thus fetuin-B deficiency renders females infertile. We determined the human serum fetuin-B reference range, studying longitudinally, over the course of one month, five male and seven female volunteers without hormone treatment and four female volunteers on varying hormonal contraception. We sampled blood and determined serum fetuin-B, luteinizing hormone (LH), estradiol (E2) and progesterone (P4). In addition, we determined serum fetuin-B and estradiol in eight women undergoing intracytoplasmatic sperm injection (ICSI, nine ICSI cycles) and 19 women undergoing IVF (21 IVF cycles) after ovarian stimulation with recombinant human follicular stimulating hormone (rFSH) and/or a combined medication of FSH and LH. At least three blood samples were analyzed in each cycle. We compared serum fetuin-B and follicular fluid fetuin-B in nine patients by measuring follicular fetuin-B in pooled follicular fluid, and in fluid obtained from individual follicles. Samples were drawn from January 2012 to March 2014. All volunteers and patients gave informed consent. Fetuin-B was measured employing a commercial sandwich enzyme-linked immunosorbent assay. Serum fetuin-B was determined as duplicates in 5 male (34 ± 14.6 years) and 11 female volunteers (29.4 ± 4.1 years) as well as in female volunteers on hormonal contraception (30.0 ± 6.5 years). The duplicate standard deviation was 4.0 ± 2.3%. The contraceptive drugs were mono or combined preparations containing 0-0.03 mg ethinyl estradiol, and 0.15-3.0 mg of various progestins. In addition, serum fetuin-B was determined as triplicates in 27 female patients undergoing conventional IVF (19) or ICSI (8). The triplicate standard deviation was 3.3 ± 1.8%. IVF was declared as 'successful', if at least one oocyte was fertilized, and 'unsuccessful', if no oocyte could be fertilized. Patient age was 34.4 ± 4.4 years in successful IVF, and 35.4 ± 3.3 years in unsuccessful IVF. Serum and follicular fluid of patients undergoing controlled ovarian hyperstimulation were analyzed. Serum was drawn at the day of follicle aspiration. Serum fetuin-B and follicular fluid fetuin-B were not significantly different in six out of nine patients suggesting, in principle, free exchange of fetuin-B between serum and follicular fluid. Thus serum fetuin-B may be used as a proxy of follicular fluid fetuin-B. Serum fetuin-B increased during successful IVF cycles (n = 15, P < 0.0001), but did not change in unsuccessful IVF cycles (n = 6, P = 0.118) despite increased estradiol levels (P = 0.0019 and P = 0.0254, respectively). The female volunteers self-reported their respective hormone medication. Medication was verified by serum estradiol, LH and progesterone measurements. For oocyte harvesting, the vaginal wall was punctured once only to minimize co-morbidity. Low grade cross-contamination of individual follicular fluid aspirates and contamination of the follicular fluid with small amounts of blood were inevitable. Samples were routinely checked for the presence of hemoglobin that would suggest blood contamination. Only samples containing <250 erythrocyte equivalents/µl were used for analysis. Serum fetuin-B may be used as a marker to predict the fertilization success in IVF. Fetuin-B levels attained during IVF stimulation may help to make an informed decision whether oocytes should be fertilized by IVF or by ICSI to overcome the zona pellucida as a barrier. The research was supported by a grant from Deutsche Forschungsgemeinschaft and by the START program of the Medical Faculty of RWTH Aachen University. J.F., E.D., J.N., B.R. and W.J.-D. declare that they are named inventors on the RWTH Aachen University patent application EP 13157317.2, 'Use of fetuin-B for culture of oocytes', applied for by RWTH Aachen University. © The Author 2016. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. Human plasma and serum extracellular small RNA reference profiles and their clinical utility.

    PubMed

    Max, Klaas E A; Bertram, Karl; Akat, Kemal Marc; Bogardus, Kimberly A; Li, Jenny; Morozov, Pavel; Ben-Dov, Iddo Z; Li, Xin; Weiss, Zachary R; Azizian, Azadeh; Sopeyin, Anuoluwapo; Diacovo, Thomas G; Adamidi, Catherine; Williams, Zev; Tuschl, Thomas

    2018-06-05

    Circulating extracellular RNAs (exRNAs) have the potential to serve as biomarkers for a wide range of medical conditions. However, limitations in existing exRNA isolation methods and a lack of knowledge on parameters affecting exRNA variability in human samples may hinder their successful discovery and clinical implementation. Using combinations of denaturants, reducing agents, proteolysis, and revised organic extraction, we developed an automated, high-throughput approach for recovery of exRNAs and exDNA from the same biofluid sample. We applied this method to characterize exRNAs from 312 plasma and serum samples collected from 13 healthy volunteers at 12 time points over a 2-month period. Small RNA cDNA library sequencing identified nearly twofold increased epithelial-, muscle-, and neuroendocrine-cell-specific miRNAs in females, while fasting and hormonal cycle showed little effect. External standardization helped to detect quantitative differences in erythrocyte and platelet-specific miRNA contributions and in miRNA concentrations between biofluids. It also helped to identify a study participant with a unique exRNA phenotype featuring a miRNA signature of up to 20-fold elevated endocrine-cell-specific miRNAs and twofold elevated total miRNA concentrations stable for over 1 year. Collectively, these results demonstrate an efficient and quantitative method to discern exRNA phenotypes and suggest that plasma and serum RNA profiles are stable over months and can be routinely monitored in long-term clinical studies. Copyright © 2018 the Author(s). Published by PNAS.

  4. Radioimmunoassay of erythropoietin: circulating levels in normal and polycythemic human beings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garcia, J.F.; Ebbe, S.N.; Hollander, L.

    1982-05-01

    Techniques are described in detail for the RIA of human Ep in unextracted plasma or serum. With 100 ..mu..l of sample, the assay is sensitive at an Ep concentration of approximately 4 mU/ml, and when required, the sensitivity can be increased to 0.4 mU/ml, a range considerably less than the concentration observed in normal human beings. This is approximately 100 times more sensitive than existing in vivo bioassays for this hormone. Studies concerned with the validation of the Ep RIA show a high degree of correlation with the polycythemic mouse bioassay. Dilutions of a variety of human serum samples showmore » a parallel relationship with the standard reference preparation for Ep. Validation of the RIA is further confirmed by observations of appropriate increases or decreases of circulating Ep levels in physiological and clinical conditions known to be associated with stimulation or suppression of Ep secretion. Significantly different mean serum concentrations of 17.2 mU/ml for normal male subjects and 18.8 mU/ml for normal female subjects were observed. Mean plasma Ep concentrations in patients with polycythemia vera are significantly decreased, and those of patients with secondary polycythemia are significantly increased as compared to plasma levels in normal subjects. These results demonstrate an initial practical value of the Ep RA in the hematology clinic, which will most certainly be expanded with its more extensive use.« less

  5. Diagnostic performance of serological tests to detect antibodies against acute scrub typhus infection in central India.

    PubMed

    Pote, Kiran; Narang, Rahul; Deshmukh, Pradeep

    2018-01-01

    Differentiating scrub typhus from other acute febrile illness is difficult due to non specificity of clinical symptoms and relative absence of eschar in Indian population. The diagnosis thus relies mainly on laboratory tests. Antibody based serological tests are mainstay of scrub typhus diagnosis. Here, we evaluated the diagnostic performance of IgM ELISA, IgM IFA and ICT to detect antibodies against O. tsutsugamushi in acute serum of febrile patients. The serum samples from 600 randomly selected patients suffering from acute undifferentiated fever were tested by all the three tests mentioned above. We used latent class analysis to generate unbiased results as all the tests for scrub typhus diagnosis are imperfect and none of them can be considered as reference standard. We found that IgM ELISA with cutoff titer 0.5 OD has high diagnostic accuracy (sensitivity 99.9% and specificity 99.15) than IgM IFA (sensitivity 96.8% and specificity 99.7%) for scrub typhus diagnosis. ICT used in our study had very high specificity 100% but low sensitivity (38%) which would limit its use for acute serum samples. ICT being a screening or point of care test, has to be more sensitive while some compromise with specificity is affordable. Hence, optimal cutoff for ICT should be evaluated under different settings. IgM ELISA being simple and affordable could be an alternative diagnostic test to IgM IFA which is subjective and costly.

  6. Multiple Myeloma and Its Precursor Disease Among Firefighters Exposed to the World Trade Center Disaster.

    PubMed

    Landgren, Ola; Zeig-Owens, Rachel; Giricz, Orsolya; Goldfarb, David; Murata, Kaznouri; Thoren, Katie; Ramanathan, Lakshmi; Hultcrantz, Malin; Dogan, Ahmet; Nwankwo, George; Steidl, Ulrich; Pradhan, Kith; Hall, Charles B; Cohen, Hillel W; Jaber, Nadia; Schwartz, Theresa; Crowley, Laura; Crane, Michael; Irby, Shani; Webber, Mayris P; Verma, Amit; Prezant, David J

    2018-06-01

    The World Trade Center (WTC) attacks on September 11, 2001, created an unprecedented environmental exposure to known and suspected carcinogens suggested to increase the risk of multiple myeloma. Multiple myeloma is consistently preceded by the precursor states of monoclonal gammopathy of undetermined significance (MGUS) and light-chain MGUS, detectable in peripheral blood. To characterize WTC-exposed firefighters with a diagnosis of multiple myeloma and to conduct a screening study for MGUS and light-chain MGUS. Case series of multiple myeloma in firefighters diagnosed between September 11, 2001, and July 1, 2017, together with a seroprevalence study of MGUS in serum samples collected from Fire Department of the City of New York (FDNY) firefighters between December 2013 and October 2015. Participants included all WTC-exposed FDNY white, male firefighters with a confirmed physician diagnosis of multiple myeloma (n = 16) and WTC-exposed FDNY white male firefighters older than 50 years with available serum samples (n = 781). WTC exposure defined as rescue and/or recovery work at the WTC site between September 11, 2001, and July 25, 2002. Multiple myeloma case information, and age-adjusted and age-specific prevalence rates for overall MGUS (ie, MGUS and light-chain MGUS), MGUS, and light-chain MGUS. Sixteen WTC-exposed white male firefighters received a diagnosis of multiple myeloma after September 11, 2001; median age at diagnosis was 57 years (interquartile range, 50-68 years). Serum/urine monoclonal protein isotype/free light-chain data were available for 14 cases; 7 (50%) had light-chain multiple myeloma. In a subset of 7 patients, myeloma cells were assessed for CD20 expression; 5 (71%) were CD20 positive. In the screening study, we assayed peripheral blood from 781 WTC-exposed firefighters. The age-standardized prevalence rate of MGUS and light-chain MGUS combined was 7.63 per 100 persons (95% CI, 5.45-9.81), 1.8-fold higher than rates from the Olmsted County, Minnesota, white male reference population (relative rate, 1.76; 95% CI, 1.34-2.29). The age-standardized prevalence rate of light-chain MGUS was more than 3-fold higher than in the same reference population (relative rate, 3.13; 95% CI, 1.99-4.93). Environmental exposure to the WTC disaster site is associated with myeloma precursor disease (MGUS and light-chain MGUS) and may be a risk factor for the development of multiple myeloma at an earlier age, particularly the light-chain subtype.

  7. Bendable Electro-chemical Lactate Sensor Printed with Silver Nano-particles

    NASA Astrophysics Data System (ADS)

    Abrar, Md Abu; Dong, Yue; Lee, Paul Kyuheon; Kim, Woo Soo

    2016-07-01

    Here we report a flexible amperometric lactate biosensor using silver nanoparticle based conductive electrode. Mechanically bendable cross-serpentine-shaped silver electrode is generated on flexible substrate for the mechanical durability such as bending. The biosensor is designed and fabricated by modifying silver electrode with lactate oxidase immobilized by bovine serum albumin. The in-sensor pseudo Ag/AgCl reference electrode is fabricated by chloridization of silver electrode, which evinced its long-term potential stability against a standard commercial Ag/AgCl reference electrode. The amperometric response of the sensor shows linear dependence with lactate concentration of 1~25 mM/L. Anionic selectivity is achieved by using drop-casted Nafion coated on silver electrode against anionic interferences such as ascorbate. This non-invasive electrochemical lactate sensor also demonstrates excellent resiliency against mechanical deformation and temperature fluctuation which leads the possibility of using it on human epidermis for continuous measurement of lactate from sweat. Near field communication based wireless data transmission is demonstrated to reflect a practical approach of the sensor to measure lactate concentration portably using human perspiration.

  8. Bendable Electro-chemical Lactate Sensor Printed with Silver Nano-particles

    PubMed Central

    Abrar, Md Abu; Dong, Yue; Lee, Paul Kyuheon; Kim, Woo Soo

    2016-01-01

    Here we report a flexible amperometric lactate biosensor using silver nanoparticle based conductive electrode. Mechanically bendable cross-serpentine-shaped silver electrode is generated on flexible substrate for the mechanical durability such as bending. The biosensor is designed and fabricated by modifying silver electrode with lactate oxidase immobilized by bovine serum albumin. The in-sensor pseudo Ag/AgCl reference electrode is fabricated by chloridization of silver electrode, which evinced its long-term potential stability against a standard commercial Ag/AgCl reference electrode. The amperometric response of the sensor shows linear dependence with lactate concentration of 1~25 mM/L. Anionic selectivity is achieved by using drop-casted Nafion coated on silver electrode against anionic interferences such as ascorbate. This non-invasive electrochemical lactate sensor also demonstrates excellent resiliency against mechanical deformation and temperature fluctuation which leads the possibility of using it on human epidermis for continuous measurement of lactate from sweat. Near field communication based wireless data transmission is demonstrated to reflect a practical approach of the sensor to measure lactate concentration portably using human perspiration. PMID:27465437

  9. Studying the Relation of Postprandial Triglyceride with Coronary Artery Disease (CAD).

    PubMed

    Manochehri, Mohammad; Moghadam, Adel Johari

    2016-07-27

    Coronary artery disease (CAD) is the most common cause of mortality worldwide and determination of contributing factors is essential. This study was conducted to study the relation of postprandial triglyceride as a risk of coronary artery disease in patients with proven CAD by angiography, referred to 502 Hospital of Army in 2015. This observational study conducted as a case-control and contained 80 male participants referred to 502 Hospital of Army. Half of these participants had proven CAD by angiography test and the other ones were healthy as a control group. Fasting serum triglyceride was evaluated in all participants and postprandial TG was checked 4 hours after a standard meal. Obtained data were analyzed by SPSS ver. 13. The results indicated that fasting TG and postprandial TG level were significantly higher in CAD patients (P-value=0.001). It was also shown evaluation of postprandial TG is more sensitive test than fasting TG in case of CAD patients. Our obtained results shown, evaluation of high level of postprandial TG is more reliable than fasting TG for patients whom suffer from CAD.

  10. Dietary safety assessment of genetically modified rice EH rich in β-carotene.

    PubMed

    Wu, Yangyang; Xu, Yan; Du, Yanan; Zhao, Xiao; Hu, Ruili; Fan, Xiaorui; Ren, Fangfang; Yao, Quanhong; Peng, Rihe; Tang, Xueming; Zhao, Kai

    2017-08-01

    This 90-day study aimed to assess the dietary safety of transgenic rice EH which is rich in β-carotene. Two experimental groups of Sprague-Dawley rats were fed diets containing 45% rice flour of Zhonghua 11 rice and transgenic rice EH rich in β-carotene, respectively. The reference group was fed a diet containing standard feed nutrition. During the trial period, each rat was weighed and the food intake was recorded twice a week. Their behaviors were observed daily. In the end, blood samples were obtained from all anesthetized rats to measure the hematologic and serum chemistry indicators. Growth performance, anatomy and pathology of all organs in each group were analyzed. Although a few parameters were found to be statistically significantly different across groups, they were within the normal reference range for this breed and age of rats. Therefore, the changes were not considered to be diet related. The results revealed that the transgenic rice EH rich in β-carotene was as nutritious as Zhonghua 11 rice and showed a lack of biologically meaningful unintended effects. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. A ribonuclease protection assay can distinguish spring viremia of carp virus from pike fry rhabdovirus

    USGS Publications Warehouse

    Ahne, W.; Kurath, G.; Winton, J.R.

    1998-01-01

    Thirteen rhabdovirus isolates from 10 teleost fish species as well as reference strains of spring viraemia of carp virus (SVCV) and pike fry rhabdovirus (PFRV) cross-reacted in an indirect immunofluorescence assay and were thus indistinguishable by this method. A ribonuclease protection assay (RPA) using a super(32)P-labeled RNA probe made from a cloned copy of the full length SVCV glycoprotein (G) gene was able to discriminate clearly between the type strains of SVCV and PFRV and among the 13 rhabdovirus isolates. Results for the RPA were generally in agreement with standard serum neutralisation assays; however, the RPA was also able to detect genomic differences between isolates of SVCV. These results have implications for fish disease control programs for SVCV.

  12. Nanoforms: a new type of protein-associated mineralization

    NASA Astrophysics Data System (ADS)

    Vali, Hojatollah; McKee, Marc D.; Çiftçioglu, Neva; Sears, S. Kelly; Plows, Fiona L.; Chevet, Eric; Ghiabi, Pegah; Plavsic, Marc; Kajander, E. Olavi; Zare, Richard N.

    2001-01-01

    Controversy surrounds the interpretation of various nano-phenomena as being living organisms. Incubation of fetal bovine serum under standard cell culture conditions results in the formation of free entities in solution, here referred to as nanoforms. These nanoforms, when examined by transmission electron microscopy, have a distinct ovoid morphology ranging in size from tens to hundreds of nanometers. They are composed of hydroxyapatite and proteins and constitute a novel form of protein-associated mineralization. No detectable cell structure resembling bacteria is apparent. However, immunodetection of the proteins associated with the nanoforms, by two specific monoclonal antibodies, suggests a possible biogenic origin. The significance of nanoforms for the recognition of biological activity in ancient geological systems is discussed. The mode of mineralization in nanoforms is also compared to matrix-mediated calcification in vertebrates.

  13. Falls relate to vitamin D and parathyroid hormone in an Australian nursing home and hostel.

    PubMed

    Stein, M S; Wark, J D; Scherer, S C; Walton, S L; Chick, P; Di Carlantonio, M; Zajac, J D; Flicker, L

    1999-10-01

    To determine whether falling relates to serum levels of vitamin D and parathyroid hormone. A cross-sectional study with retrospective analysis. An aged-care institution in Melbourne Australia. Ambulant nursing home and hostel residents (n = 83). Frequency of falling, frequency of going outdoors, use of cane or walker, age, sex, weight, type of accommodation, and duration of residence. Serum concentrations of 25-hydroxyvitamin D, 1,25-dihydroxyvitamin D, and parathyroid hormone (PTH). Plasma concentrations of albumin, calcium, phosphate, and creatinine. Use of furosemide or non-benzodiazepine anticonvulsants. Median age of residents was 84 years. The cohort was vitamin D deficient with a median (interquartile range) 25-hydroxyvitamin D level of 27 (18-37) nmol/L (one-third the reference range median), P < .001. The median (interquartile range) PTH of 5.2 (3.8-7.7) pmol/L exceeded the reference range median, P < .001. Residents who fell (n = 33) had lower serum 25-hydroxyvitamin D levels than other residents (medians 22 vs 29 nmol/L, P = .02) and higher serum PTH levels (medians 6.2 vs 4.8 pmol/L, P < .01). Sixty residents lived in the hostel (72%), and 41 (49%) walked without any walking aid. In a multiple logistic regression for falling, higher serum PTH remained independently associated with falling, with an odds ratio (95% confidence interval) for falling of 5.6 (1.7-18.5) per unit of the natural logarithm of serum PTH. Other terms in the regression were hostel accommodation, odds ratio .04 (.01-.25), and ability to walk without aids, odds ratio .07 (.01-.37). In ambulant nursing home and hostel residents, residents who fall have lower serum 25-hydroxyvitamin D and higher serum parathyroid hormone levels than other residents. The association between falling and serum PTH persists after adjustment for other variables.

  14. Diagnostic accuracy of calculated serum osmolarity to predict dehydration in older people: adding value to pathology laboratory reports

    PubMed Central

    Hooper, Lee; Abdelhamid, Asmaa; Ali, Adam; Bunn, Diane K; Jennings, Amy; John, W Garry; Kerry, Susan; Lindner, Gregor; Pfortmueller, Carmen A; Sjöstrand, Fredrik; Walsh, Neil P; Fairweather-Tait, Susan J; Potter, John F; Hunter, Paul R; Shepstone, Lee

    2015-01-01

    Objectives To assess which osmolarity equation best predicts directly measured serum/plasma osmolality and whether its use could add value to routine blood test results through screening for dehydration in older people. Design Diagnostic accuracy study. Participants Older people (≥65 years) in 5 cohorts: Dietary Strategies for Healthy Ageing in Europe (NU-AGE, living in the community), Dehydration Recognition In our Elders (DRIE, living in residential care), Fortes (admitted to acute medical care), Sjöstrand (emergency room) or Pfortmueller cohorts (hospitalised with liver cirrhosis). Reference standard for hydration status Directly measured serum/plasma osmolality: current dehydration (serum osmolality >300 mOsm/kg), impending/current dehydration (≥295 mOsm/kg). Index tests 39 osmolarity equations calculated using serum indices from the same blood draw as directly measured osmolality. Results Across 5 cohorts 595 older people were included, of whom 19% were dehydrated (directly measured osmolality >300 mOsm/kg). Of 39 osmolarity equations, 5 showed reasonable agreement with directly measured osmolality and 3 had good predictive accuracy in subgroups with diabetes and poor renal function. Two equations were characterised by narrower limits of agreement, low levels of differential bias and good diagnostic accuracy in receiver operating characteristic plots (areas under the curve >0.8). The best equation was osmolarity=1.86×(Na++ K+)+1.15×glucose+urea+14 (all measured in mmol/L). It appeared useful in people aged ≥65 years with and without diabetes, poor renal function, dehydration, in men and women, with a range of ages, health, cognitive and functional status. Conclusions Some commonly used osmolarity equations work poorly, and should not be used. Given costs and prevalence of dehydration in older people we suggest use of the best formula by pathology laboratories using a cutpoint of 295 mOsm/L (sensitivity 85%, specificity 59%), to report dehydration risk opportunistically when serum glucose, urea and electrolytes are measured for other reasons in older adults. Trial registration numbers: DRIE: Research Register for Social Care, 122273; NU-AGE: ClinicalTrials.gov NCT01754012. PMID:26490100

  15. Validity of the International Classification of Diseases 10th revision code for hospitalisation with hyponatraemia in elderly patients

    PubMed Central

    Gandhi, Sonja; Shariff, Salimah Z; Fleet, Jamie L; Weir, Matthew A; Jain, Arsh K; Garg, Amit X

    2012-01-01

    Objective To evaluate the validity of the International Classification of Diseases, 10th Revision (ICD-10) diagnosis code for hyponatraemia (E87.1) in two settings: at presentation to the emergency department and at hospital admission. Design Population-based retrospective validation study. Setting Twelve hospitals in Southwestern Ontario, Canada, from 2003 to 2010. Participants Patients aged 66 years and older with serum sodium laboratory measurements at presentation to the emergency department (n=64 581) and at hospital admission (n=64 499). Main outcome measures Sensitivity, specificity, positive predictive value and negative predictive value comparing various ICD-10 diagnostic coding algorithms for hyponatraemia to serum sodium laboratory measurements (reference standard). Median serum sodium values comparing patients who were code positive and code negative for hyponatraemia. Results The sensitivity of hyponatraemia (defined by a serum sodium ≤132 mmol/l) for the best-performing ICD-10 coding algorithm was 7.5% at presentation to the emergency department (95% CI 7.0% to 8.2%) and 10.6% at hospital admission (95% CI 9.9% to 11.2%). Both specificities were greater than 99%. In the two settings, the positive predictive values were 96.4% (95% CI 94.6% to 97.6%) and 82.3% (95% CI 80.0% to 84.4%), while the negative predictive values were 89.2% (95% CI 89.0% to 89.5%) and 87.1% (95% CI 86.8% to 87.4%). In patients who were code positive for hyponatraemia, the median (IQR) serum sodium measurements were 123 (119–126) mmol/l and 125 (120–130) mmol/l in the two settings. In code negative patients, the measurements were 138 (136–140) mmol/l and 137 (135–139) mmol/l. Conclusions The ICD-10 diagnostic code for hyponatraemia differentiates between two groups of patients with distinct serum sodium measurements at both presentation to the emergency department and at hospital admission. However, these codes underestimate the true incidence of hyponatraemia due to low sensitivity. PMID:23274673

  16. The reference intervals of thyroid stimulating hormone in healthy individuals with normal levels of serum free thyroxine and without sonographic pathologies.

    PubMed

    Kutluturk, Faruk; Yildirim, Beytullah; Ozturk, Banu; Ozyurt, Huseyin; Bekar, Ulku; Sahin, Semsettin; Akturk, Yeliz; Akbas, Ali; Cetin, Ilhan; Etikan, Ilker

    2014-01-01

    The aim of the present study was to investigate the reference intervals for thyroid stimulating hormone (TSH) in healthy individuals with normal levels of serum free thyroxine (fT4) and without sonographic pathologies, and determine the effects of age, gender, and residence on the TSH reference intervals. This research was a population-based study conducted in 70 regions. The random sampling method was used to select the 1095 subjects of the study among inhabitants aged 18 and above. Patients who had a previous history of thyroid disease and had been taking medication were excluded from the study as this may have affected their fT4 or TSH levels. In addition, subjects who had serum fT4 without a reference range and abnormal ultrasonography findings were also excluded. A total of 408 subjects were used for establishing the reference intervals for TSH. The data for TSH in the study group were not normally distributed according to the Kolmogorov-Smirnov index. The geometric mean was 1.62 mIU/L, the median was 1.40 mIU/L, and the 95% reference intervals were 0.38-4.22 mIU/L. The median TSH level was higher in females compared to males (p < 0.05). In the female subjects 2.5th percentile of TSH was lower and 97.5th percentile was higher than those of males. The reference intervals of TSH were of lower values in subjects over 50 years old (p < 0.001). Studies suggest that determination of the TSH reference intervals may differ due to environmental influences or due to age, gender, and race. It is suggested that the lower limit of normal TSH for the adult Turkish population would be 0.38 mIU/L and the upper limit similar to the traditional value of 4.2 mIU/L. If each clinician uses their population-specific reference interval for TSH, thyroid function abnormalities can be accurately estimated.

  17. [Application of traditional Chinese medicine reference standards in quality control of Chinese herbal pieces].

    PubMed

    Lu, Tu-Lin; Li, Jin-Ci; Yu, Jiang-Yong; Cai, Bao-Chang; Mao, Chun-Qin; Yin, Fang-Zhou

    2014-01-01

    Traditional Chinese medicine (TCM) reference standards plays an important role in the quality control of Chinese herbal pieces. This paper overviewed the development of TCM reference standards. By analyzing the 2010 edition of Chinese pharmacopoeia, the application of TCM reference standards in the quality control of Chinese herbal pieces was summarized, and the problems exiting in the system were put forward. In the process of improving the quality control level of Chinese herbal pieces, various kinds of advanced methods and technology should be used to research the characteristic reference standards of Chinese herbal pieces, more and more reasonable reference standards should be introduced in the quality control system of Chinese herbal pieces. This article discussed the solutions in the aspect of TCM reference standards, and future development of quality control on Chinese herbal pieces is prospected.

  18. A multilaboratory comparison of calibration accuracy and the performance of external references in analytical ultracentrifugation.

    PubMed

    Zhao, Huaying; Ghirlando, Rodolfo; Alfonso, Carlos; Arisaka, Fumio; Attali, Ilan; Bain, David L; Bakhtina, Marina M; Becker, Donald F; Bedwell, Gregory J; Bekdemir, Ahmet; Besong, Tabot M D; Birck, Catherine; Brautigam, Chad A; Brennerman, William; Byron, Olwyn; Bzowska, Agnieszka; Chaires, Jonathan B; Chaton, Catherine T; Cölfen, Helmut; Connaghan, Keith D; Crowley, Kimberly A; Curth, Ute; Daviter, Tina; Dean, William L; Díez, Ana I; Ebel, Christine; Eckert, Debra M; Eisele, Leslie E; Eisenstein, Edward; England, Patrick; Escalante, Carlos; Fagan, Jeffrey A; Fairman, Robert; Finn, Ron M; Fischle, Wolfgang; de la Torre, José García; Gor, Jayesh; Gustafsson, Henning; Hall, Damien; Harding, Stephen E; Cifre, José G Hernández; Herr, Andrew B; Howell, Elizabeth E; Isaac, Richard S; Jao, Shu-Chuan; Jose, Davis; Kim, Soon-Jong; Kokona, Bashkim; Kornblatt, Jack A; Kosek, Dalibor; Krayukhina, Elena; Krzizike, Daniel; Kusznir, Eric A; Kwon, Hyewon; Larson, Adam; Laue, Thomas M; Le Roy, Aline; Leech, Andrew P; Lilie, Hauke; Luger, Karolin; Luque-Ortega, Juan R; Ma, Jia; May, Carrie A; Maynard, Ernest L; Modrak-Wojcik, Anna; Mok, Yee-Foong; Mücke, Norbert; Nagel-Steger, Luitgard; Narlikar, Geeta J; Noda, Masanori; Nourse, Amanda; Obsil, Tomas; Park, Chad K; Park, Jin-Ku; Pawelek, Peter D; Perdue, Erby E; Perkins, Stephen J; Perugini, Matthew A; Peterson, Craig L; Peverelli, Martin G; Piszczek, Grzegorz; Prag, Gali; Prevelige, Peter E; Raynal, Bertrand D E; Rezabkova, Lenka; Richter, Klaus; Ringel, Alison E; Rosenberg, Rose; Rowe, Arthur J; Rufer, Arne C; Scott, David J; Seravalli, Javier G; Solovyova, Alexandra S; Song, Renjie; Staunton, David; Stoddard, Caitlin; Stott, Katherine; Strauss, Holger M; Streicher, Werner W; Sumida, John P; Swygert, Sarah G; Szczepanowski, Roman H; Tessmer, Ingrid; Toth, Ronald T; Tripathy, Ashutosh; Uchiyama, Susumu; Uebel, Stephan F W; Unzai, Satoru; Gruber, Anna Vitlin; von Hippel, Peter H; Wandrey, Christine; Wang, Szu-Huan; Weitzel, Steven E; Wielgus-Kutrowska, Beata; Wolberger, Cynthia; Wolff, Martin; Wright, Edward; Wu, Yu-Sung; Wubben, Jacinta M; Schuck, Peter

    2015-01-01

    Analytical ultracentrifugation (AUC) is a first principles based method to determine absolute sedimentation coefficients and buoyant molar masses of macromolecules and their complexes, reporting on their size and shape in free solution. The purpose of this multi-laboratory study was to establish the precision and accuracy of basic data dimensions in AUC and validate previously proposed calibration techniques. Three kits of AUC cell assemblies containing radial and temperature calibration tools and a bovine serum albumin (BSA) reference sample were shared among 67 laboratories, generating 129 comprehensive data sets. These allowed for an assessment of many parameters of instrument performance, including accuracy of the reported scan time after the start of centrifugation, the accuracy of the temperature calibration, and the accuracy of the radial magnification. The range of sedimentation coefficients obtained for BSA monomer in different instruments and using different optical systems was from 3.655 S to 4.949 S, with a mean and standard deviation of (4.304 ± 0.188) S (4.4%). After the combined application of correction factors derived from the external calibration references for elapsed time, scan velocity, temperature, and radial magnification, the range of s-values was reduced 7-fold with a mean of 4.325 S and a 6-fold reduced standard deviation of ± 0.030 S (0.7%). In addition, the large data set provided an opportunity to determine the instrument-to-instrument variation of the absolute radial positions reported in the scan files, the precision of photometric or refractometric signal magnitudes, and the precision of the calculated apparent molar mass of BSA monomer and the fraction of BSA dimers. These results highlight the necessity and effectiveness of independent calibration of basic AUC data dimensions for reliable quantitative studies.

  19. A Multilaboratory Comparison of Calibration Accuracy and the Performance of External References in Analytical Ultracentrifugation

    PubMed Central

    Zhao, Huaying; Ghirlando, Rodolfo; Alfonso, Carlos; Arisaka, Fumio; Attali, Ilan; Bain, David L.; Bakhtina, Marina M.; Becker, Donald F.; Bedwell, Gregory J.; Bekdemir, Ahmet; Besong, Tabot M. D.; Birck, Catherine; Brautigam, Chad A.; Brennerman, William; Byron, Olwyn; Bzowska, Agnieszka; Chaires, Jonathan B.; Chaton, Catherine T.; Cölfen, Helmut; Connaghan, Keith D.; Crowley, Kimberly A.; Curth, Ute; Daviter, Tina; Dean, William L.; Díez, Ana I.; Ebel, Christine; Eckert, Debra M.; Eisele, Leslie E.; Eisenstein, Edward; England, Patrick; Escalante, Carlos; Fagan, Jeffrey A.; Fairman, Robert; Finn, Ron M.; Fischle, Wolfgang; de la Torre, José García; Gor, Jayesh; Gustafsson, Henning; Hall, Damien; Harding, Stephen E.; Cifre, José G. Hernández; Herr, Andrew B.; Howell, Elizabeth E.; Isaac, Richard S.; Jao, Shu-Chuan; Jose, Davis; Kim, Soon-Jong; Kokona, Bashkim; Kornblatt, Jack A.; Kosek, Dalibor; Krayukhina, Elena; Krzizike, Daniel; Kusznir, Eric A.; Kwon, Hyewon; Larson, Adam; Laue, Thomas M.; Le Roy, Aline; Leech, Andrew P.; Lilie, Hauke; Luger, Karolin; Luque-Ortega, Juan R.; Ma, Jia; May, Carrie A.; Maynard, Ernest L.; Modrak-Wojcik, Anna; Mok, Yee-Foong; Mücke, Norbert; Nagel-Steger, Luitgard; Narlikar, Geeta J.; Noda, Masanori; Nourse, Amanda; Obsil, Tomas; Park, Chad K.; Park, Jin-Ku; Pawelek, Peter D.; Perdue, Erby E.; Perkins, Stephen J.; Perugini, Matthew A.; Peterson, Craig L.; Peverelli, Martin G.; Piszczek, Grzegorz; Prag, Gali; Prevelige, Peter E.; Raynal, Bertrand D. E.; Rezabkova, Lenka; Richter, Klaus; Ringel, Alison E.; Rosenberg, Rose; Rowe, Arthur J.; Rufer, Arne C.; Scott, David J.; Seravalli, Javier G.; Solovyova, Alexandra S.; Song, Renjie; Staunton, David; Stoddard, Caitlin; Stott, Katherine; Strauss, Holger M.; Streicher, Werner W.; Sumida, John P.; Swygert, Sarah G.; Szczepanowski, Roman H.; Tessmer, Ingrid; Toth, Ronald T.; Tripathy, Ashutosh; Uchiyama, Susumu; Uebel, Stephan F. W.; Unzai, Satoru; Gruber, Anna Vitlin; von Hippel, Peter H.; Wandrey, Christine; Wang, Szu-Huan; Weitzel, Steven E.; Wielgus-Kutrowska, Beata; Wolberger, Cynthia; Wolff, Martin; Wright, Edward; Wu, Yu-Sung; Wubben, Jacinta M.; Schuck, Peter

    2015-01-01

    Analytical ultracentrifugation (AUC) is a first principles based method to determine absolute sedimentation coefficients and buoyant molar masses of macromolecules and their complexes, reporting on their size and shape in free solution. The purpose of this multi-laboratory study was to establish the precision and accuracy of basic data dimensions in AUC and validate previously proposed calibration techniques. Three kits of AUC cell assemblies containing radial and temperature calibration tools and a bovine serum albumin (BSA) reference sample were shared among 67 laboratories, generating 129 comprehensive data sets. These allowed for an assessment of many parameters of instrument performance, including accuracy of the reported scan time after the start of centrifugation, the accuracy of the temperature calibration, and the accuracy of the radial magnification. The range of sedimentation coefficients obtained for BSA monomer in different instruments and using different optical systems was from 3.655 S to 4.949 S, with a mean and standard deviation of (4.304 ± 0.188) S (4.4%). After the combined application of correction factors derived from the external calibration references for elapsed time, scan velocity, temperature, and radial magnification, the range of s-values was reduced 7-fold with a mean of 4.325 S and a 6-fold reduced standard deviation of ± 0.030 S (0.7%). In addition, the large data set provided an opportunity to determine the instrument-to-instrument variation of the absolute radial positions reported in the scan files, the precision of photometric or refractometric signal magnitudes, and the precision of the calculated apparent molar mass of BSA monomer and the fraction of BSA dimers. These results highlight the necessity and effectiveness of independent calibration of basic AUC data dimensions for reliable quantitative studies. PMID:25997164

  20. 9 CFR 101.6 - Cell cultures.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Cell cultures. 101.6 Section 101.6..., SERUMS, TOXINS, AND ANALOGOUS PRODUCTS; ORGANISMS AND VECTORS DEFINITIONS § 101.6 Cell cultures. When used in conjunction with or in reference to cell cultures, which may be referred to as tissue cultures...

  1. 9 CFR 101.6 - Cell cultures.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 9 Animals and Animal Products 1 2012-01-01 2012-01-01 false Cell cultures. 101.6 Section 101.6..., SERUMS, TOXINS, AND ANALOGOUS PRODUCTS; ORGANISMS AND VECTORS DEFINITIONS § 101.6 Cell cultures. When used in conjunction with or in reference to cell cultures, which may be referred to as tissue cultures...

  2. 9 CFR 101.6 - Cell cultures.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 9 Animals and Animal Products 1 2013-01-01 2013-01-01 false Cell cultures. 101.6 Section 101.6..., SERUMS, TOXINS, AND ANALOGOUS PRODUCTS; ORGANISMS AND VECTORS DEFINITIONS § 101.6 Cell cultures. When used in conjunction with or in reference to cell cultures, which may be referred to as tissue cultures...

  3. 9 CFR 101.6 - Cell cultures.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 9 Animals and Animal Products 1 2014-01-01 2014-01-01 false Cell cultures. 101.6 Section 101.6..., SERUMS, TOXINS, AND ANALOGOUS PRODUCTS; ORGANISMS AND VECTORS DEFINITIONS § 101.6 Cell cultures. When used in conjunction with or in reference to cell cultures, which may be referred to as tissue cultures...

  4. 9 CFR 101.6 - Cell cultures.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 1 2011-01-01 2011-01-01 false Cell cultures. 101.6 Section 101.6..., SERUMS, TOXINS, AND ANALOGOUS PRODUCTS; ORGANISMS AND VECTORS DEFINITIONS § 101.6 Cell cultures. When used in conjunction with or in reference to cell cultures, which may be referred to as tissue cultures...

  5. A microbiological method for determining serum levels of broad spectrum β-lactam antibiotics in critically ill patients.

    PubMed

    Fridlund, Jimmy; Woksepp, Hanna; Schön, Thomas

    2016-10-01

    Recent studies show that suboptimal blood levels of β-lactam antibiotics are present in intensive care unit (ICU) patients. A common reference method for assessing drug concentrations is liquid chromatography coupled with mass-spectrometry (LC-MS) which is highly accurate but rarely available outside reference centres. Thus, our aim was to develop a microbiological method for monitoring β-lactam antibiotic serum levels which could be used at any hospital with a microbiological laboratory. The method was developed as a 96-well broth microdilution format to assess the concentrations of cefotaxime (CTX), meropenem (MER), and piperacillin (PIP). Patient serum containing antibiotics were diluted in suspensions of bacteria with known minimal inhibitory concentrations (MICs). Serum antibiotic concentrations were calculated by dividing the MIC with the dilution factor at which the serum inhibited growth of the bacterial suspension. Serum (n=88) from ICU patients at four hospitals in south-east Sweden were analysed and compared to LC-MS analysis. The overall accuracy and precision for spiked samples and patient samples was within the pre-set target of ±20.0% for all drugs. There was a significant correlation between the microbiological assay and LC-MS for the patient samples (CTX: r=0.86, n=31; MER: r=0.96, n=11; PIP: r=0.88, n=39) and the agreement around the clinical cut-off for CTX (4.0mg/l), MER (2.0mg/l) and PIP (16.0mg/l) was 90%, 100% and 87%, respectively. The microbiological method has a performance for determination of serum levels of meropenem, piperacillin and cefotaxime suitable for clinical use. It is an inexpensive method applicable in any microbiology laboratory. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Isotopic analysis of Cu in blood serum by multi-collector ICP-mass spectrometry: a new approach for the diagnosis and prognosis of liver cirrhosis?

    PubMed

    Costas-Rodríguez, Marta; Anoshkina, Yulia; Lauwens, Sara; Van Vlierberghe, Hans; Delanghe, Joris; Vanhaecke, Frank

    2015-03-01

    The isotopic composition of blood serum Cu has been investigated as a potential parameter for the diagnosis and prognosis of liver cirrhosis. Serum samples from supposedly healthy women (reference population) and from a group of female patients suffering from liver cirrhosis of different etiologies were analysed. The procedure for isolation of serum Cu and the measurement protocol for its isotopic analysis by multi-collector inductively coupled plasma-mass spectrometry (MC-ICP-MS) were evaluated. Significant differences in the isotopic composition of Cu were observed between the reference population and the patients. A wide spread in δ(65)Cu was observed within the cirrhosis population and δ(65)Cu seems to be linked to the severity of the disease. Patients with end-stage liver disease showed a significantly lighter serum Cu isotopic composition. Many clinical parameters used for the diagnosis and monitoring of liver diseases, i.e. the levels of aspartate aminotransferase, De Ritis ratio, prothrombin and international normalized ratio, albumin, bilirubin, Na and C-reactive protein, correlate well with the δ(65)Cu values, as did the ceruloplasmin level and the ceruloplasmin/Cu concentration ratio. The isotopic composition of serum Cu appears to reveal the synthetic and hepatocellular function of the liver synergistically with inflammation and fluid retention in the cohort studied. A relevant relationship was also observed between δ(65)Cu and scores of mortality risk, such as the Model for End-stage Liver Disease (MELD) and MELD-Na. Thus, the isotopic composition of serum Cu shows potential as a new approach for the prognosis of liver disease, and although further investigation is required, for evaluation of the mortality risk in end-stage liver disease and prioritization of liver transplants.

  7. Validating urinary measurement of beta-2-microglobulin with a Roche reagent kit designed for serum measurements.

    PubMed

    Chan, Pak Cheung R; Kulasingam, Vathany; Lem-Ragosnig, Bonny

    2012-11-01

    To validate the use of a Roche serum beta-2-microglobulin (B2MG) kit for urinary B2MG measurements, and to establish reference limits for urinary B2MG/creatinine ratio from healthy individuals. The Roche B2MG Tina-Quant serum kit was used to measure urinary B2MG immunoturbidimetrically. Using human urine as a diluent, the B2MG method was linear from 73-2156 μg/L. The imprecision on a commercially available urine QC was 4.4% at a concentration of 380 μg/L. Limit of quantification at <20% CV was 40 μg/L. Method comparison with Immulite 2000 (Siemens) yielded slope=1.180 (95% CI 1.14-1.22), intercept=11.5 (95% CI -3.6-26.6), SEE=27.6 and r=0.99 (n=26) by the Deming regression analysis. The upper reference limit of B2MG/creatinine ratio determined from 195 healthy adults was 29 μg/mmol (97.5th centile). The serum B2MG Tina Quant reagent kit is acceptable to measure urinary B2MG. Copyright © 2012. Published by Elsevier Inc.

  8. Serum zinc, copper, retinol-binding protein, prealbumin, and ceruloplasmin concentrations in infants receiving intravenous zinc and copper supplementation.

    PubMed

    Lockitch, G; Godolphin, W; Pendray, M R; Riddell, D; Quigley, G

    1983-02-01

    One hundred twenty-seven newborn infants requiring parenteral nutrition were randomly assigned to receive differing amounts of zinc (40 to 400 micrograms/kg/day) and copper (20 or 40 micrograms/kg/day) supplementation within five birth weight groups (600 to 2,500 gm). The serum zinc concentration remained relatively constant in the group receiving the most zinc supplementation after two weeks of therapy, but declined sharply in the groups receiving less supplementation. No effect of increased copper intake was noted on ceruloplasmin values, but a difference in serum copper concentrations was noted at two weeks. No correlation was noted between serum zinc and copper values or among those for serum zinc, retinol-binding protein, and prealbumin. Reference ranges were defined for serum zinc, copper, retinol-binding protein, prealbumin, and ceruloplasmin in the preterm infant.

  9. The effect of red cell and plasma transfusion on serum zinc and copper levels in the neonate.

    PubMed

    Lockitch, G; Godolphin, W J; Pendray, M R; Quigley, G

    1983-11-01

    Transfusion of packed red cells (15 to 20 ml/kg) in 11 preterm infants resulted in a slight increase in mean serum zinc levels on the 3rd post transfusion day but no effect was noted on serum copper levels. No significant difference was found between the changes in serum zinc in 141 paired specimens collected a week apart when zero, one, two or three packed cell transfusions were given in the intervening week. A slight decrease in the mean copper level was noted when one transfusion was given. Transfusion of fresh frozen plasma in six newborns with abdominal wall defects resulted in initial serum copper levels two to three times greater than the reference mean for newborns. No effect was noted on zinc levels. Serum copper results should be interpreted with caution in infants who have been transfused with plasma.

  10. PFGE standard operating procedures for Listeria monocytogenes: harmonizing the typing of food and clinical strains in Europe.

    PubMed

    Michelon, Damien; Félix, Benjamin; Vingadassalon, Noemie; Mariet, Jean-François; Larsson, Jonas T; Møller-Nielsen, Eva; Roussel, Sophie

    2015-03-01

    Listeria monocytogenes is a foodborne pathogen responsible for a severe disease known as listeriosis. The European Centre for Disease Prevention and Control (ECDC) coordinates a network of national public health laboratories (NPHLs) in charge of typing clinical strains. In food, it is the European Union Reference Laboratory for L. monocytogenes (EURL Lm), which manages a network of National Reference Laboratories (NRLs). A pulsed-field gel electrophoresis (PFGE) standard operating procedure (EURL SOP) has been used routinely at the EURL Lm since 2007. The EURL Lm has recommended that NRLs use the EURL SOP, whereas the Statens Serum Institut (SSI), under contract for ECDC, requested that NPHLs use Halpins' SOP (HSOP) published in 2010 for the PulseNet USA network. An update of Halpins' SOP (uHSOP) was published in 2013. To facilitate the exchange of profiles among human and food European reference laboratories, it is crucial to ensure that the PFGE profiles obtained with these different SOPs are comparable. The aim here was to compare the EURL SOP with HSOP and uHSOP. The panel comprised 114 well-characterized SSI/EURL strains. All were characterized at the EURL using both the EURL SOP and uHSOP. Seventy of the 114 strains were also characterized at the SSI using HSOP. The EURL SOP and uHSOP produced indistinguishable combined (ApaI/AscI) profiles for the 114 strains tested. The EURL SOP and HSOP produced indistinguishable combined profiles for 69 of the 70 strains tested. One strain displayed for the AscI profile an additional low-intensity band at 184 kbp with HSOP. For this strain, SSI and EUR Lm had already observed the same profile from NPHLs and NRLs. However, this deviation is minor as it accounted for about 1% of all the 114 combined profiles. This study should facilitate the exchange of reproducible PFGE profiles among human and food reference laboratories.

  11. Folate and vitamin B12 status of adolescent girls in northern Nigeria.

    PubMed Central

    VanderJagt, D. J.; Spelman, K.; Ambe, J.; Datta, P.; Blackwell, W.; Crossey, M.; Glew, R. H.

    2000-01-01

    The diets of populations in many developing countries are low in folate and vitamin B12 and a deficiency of either of these vitamins results in increased risk for cardiovascular disease and neural tube defects. The rates of neural tube defects in Nigeria are among the highest reported worldwide. Since many girls marry at an early age in northern Nigeria, we therefore determined the folate and vitamin B12 status of adolescent girls between 12 and 16 years of age in Maiduguri, Nigeria. The mean serum folate concentration for subjects was 15.3 +/- 5.2 nmol/L. Whereas only four subjects (2.4%) had serum folate concentrations lower than 6.8 nmol/L, a level indicative of negative folate balance, 9% of the subjects had serum vitamin B12 concentrations at or below 134 pmol/L, the lower limit of the reference range for their age group. Serum homocysteine was measured in 56 of the 162 subjects and the mean level was 15.9 +/- 5.0 mumol/L. The majority of subjects had serum homocysteine concentrations above the upper limit of the reference range for their age group. We conclude that the adolescent girls we studied were at greater risk for vitamin B12 deficiency than folate deficiency. This conclusion is consistent with the fact that their diet included few foods that contained vitamin B12. PMID:10946529

  12. Oral cobalamin supplementation in cats with hypocobalaminaemia: a retrospective study.

    PubMed

    Toresson, Linda; Steiner, Joerg M; Olmedal, Gunilla; Larsen, MajBritt; Suchodolski, Jan S; Spillmann, Thomas

    2017-12-01

    Objectives The objective of the study was to evaluate whether oral cobalamin supplementation can restore normocobal-aminaemia in cats with hypocobalaminaemia and clinical signs of gastrointestinal disease. Methods This was a retrospective study based on a computerised database search for client-owned cats treated at Evidensia Specialist Animal Hospital, Helsingborg, Sweden, during the period December 2013 to August 2016. Inclusion criteria were cats with clinical signs of chronic enteropathy, an initial serum cobalamin concentration ⩽250 pmol/l (reference interval 214-738 pmol/l) and oral treatment with cobalamin tablets. Results Twenty-five cats met the inclusion criteria. The cats were treated with 0.25 mg cyanocobalamin tablets once daily. Serum cobalamin concentration was rechecked 27-94 days after continuous oral cobalamin supplementation. All cats had serum cobalamin concentrations above the reference interval after oral cobalamin supplementation. Median (range) serum cobalamin concentration was 128 pmol/l (111-250 pmol/l) prior to treatment and 2701 pmol/l (738-16,359 pmol/l) after supplementation. This difference was statistically significant ( P <0.0001). Conclusions and relevance Our results suggest that oral cobalamin supplementation is effective in increasing serum cobalamin to supranormal concentrations in cats with hypocobalaminaemia. Thus, oral cobalamin supplementation is a promising alternative to parenteral administration. Prospective comparative studies in cats being treated with parenteral vs oral cobalamin supplementation in a larger number of patients are warranted before oral supplementation can be recommended for routine use.

  13. Effect of Intravenous Administration of Contrast Media on Serum Creatinine Levels in Neonates.

    PubMed

    Bedoya, Maria A; White, Ammie M; Edgar, J Christopher; Pradhan, Madhura; Raab, Elisabeth L; Meyer, James S

    2017-08-01

    Purpose To assess the effect of intravenous contrast media on renal function in neonates. Materials and Methods Institutional review board approval was obtained with waiver of consent. Electronic health records from January 2011 to April 2013 were reviewed retrospectively. Measures of renal function were obtained in inpatient neonates who underwent magnetic resonance (MR) imaging or computed tomography (CT) and for whom serum creatinine (Cr) levels were obtained within 72 hours before imaging and at least one time after imaging (>1 day after administration of contrast material). A total of 140 neonates who received contrast material (59 who underwent CT with iohexol or iodixanol and 81 who underwent MR imaging with gadopentetate dimeglumine) were identified. These neonates were frequency matched according to sex, gestational and postnatal age, and preimaging serum Cr levels with neonates who underwent unenhanced MR imaging or CT. Cr levels and glomerular filtration rates (GFRs) were grouped according to when they were obtained (before imaging, 1-2 days after imaging, 3-5 days after imaging, 6-9 days after imaging, 10-45 days after imaging, and more than 45 days after imaging). Serum Cr levels and GFRs for each time period were compared between groups by using hierarchic regressions or χ 2 or Fisher exact tests and with repeated-measures analysis of variance to compare groups on the rate of change in serum Cr levels and GFRs from before to after imaging. Results Cr levels decreased and GFRs increased in both groups from before to after imaging (CT group, P ≤ .01; MR imaging group, P ≤ .01). The neonates who underwent contrast material-enhanced imaging and the neonates who underwent unenhanced imaging showed similar serum Cr levels at all examined time periods. Groups also did not differ in the proportion of neonates with serum Cr levels higher than the reference range (>0.4 mg/dL) at any time point (iodine- [P > .12] or gadolinium-based [P > .13] contrast material). Similar findings were observed for GFRs. None of the neonates developed nephrogenic systemic fibrosis. Conclusion In the absence of known renal failure, neonates receiving standard inpatient care do not appear to be at increased risk for developing renal toxicity due to administration of intravenous iodine- and gadolinium-based contrast material. © RSNA, 2017.

  14. A cross-sectional study of sarcopenia in Japanese men and women: reference values and association with cardiovascular risk factors.

    PubMed

    Sanada, K; Miyachi, M; Tanimoto, M; Yamamoto, K; Murakami, H; Okumura, S; Gando, Y; Suzuki, K; Tabata, I; Higuchi, M

    2010-09-01

    In this study of Japanese men and women, we determine reference values for sarcopenia and test the hypothesis that sarcopenia is associated with risk factors for cardiovascular disease, independent of waist circumference. A total of 1,488 Japanese men and women aged 18-85 years participated in this study. Appendicular muscle mass (AMM) was measured by dual-energy X-ray absorptiometry. Reference values for classes 1 and 2 sarcopenia (skeletal muscle index: AMM/height2, kg m-2) in each sex were defined as values one and two standard deviations below the sex-specific means of reference values obtained in this study from young adults aged 18-40 years. The reference values for class 1 and class 2 sarcopenia were 7.77 and 6.87 kg m-2 in men and 6.12 and 5.46 kg m-2 in women. In subjects both with class 1 and class 2 sarcopenia, body mass index and % body fat were significantly lower than in normal subjects. Despite whole-blood glycohaemoglobin A1c in men with class 1 sarcopenia was significantly higher than in normal subjects, and brachial-ankle pulse wave velocity in women both with class 1 and class 2 sarcopenia were significantly higher than in normal subjects, using one-way ANCOVA with adjustment for the covariate of waist circumference. Although sarcopenia is associated with thin body mass, it is associated with more glycation of serum proteins in men and with greater arterial stiffness in women, independent of waist circumference.

  15. Canine cancer screening via ultraviolet absorbance and fluorescence spectroscopy of serum proteins

    NASA Astrophysics Data System (ADS)

    Dickerson, Bryan D.; Geist, Brian L.; Spillman, William B., Jr.; Robertson, John L.

    2007-11-01

    A cost-effective optical cancer screening and monitoring technique was demonstrated in a pilot study of canine serum samples and was patented for commercialization. Compared to conventional blood chemistry analysis methods, more accurate estimations of the concentrations of albumin, globulins, and hemoglobin in serum were obtained by fitting the near UV absorbance and photoluminescence spectra of diluted serum as a linear combination of component reference spectra. Tracking these serum proteins over the course of treatment helped to monitor patient immune response to carcinoma and therapy. For cancer screening, 70% of dogs with clinical presentation of cancer displayed suppressed serum hemoglobin levels (below 20 mg/dL) in combination with atypical serum protein compositions, that is, albumin levels outside of a safe range (from 4 to 8 g/dL) and globulin levels above or below a more normal range (from 1.7 to 3.7 g/dL). Of the dogs that met these criteria, only 20% were given a false positive label by this cancer screening test.

  16. Final report on CCQM-K80: Comparison of value-assigned CRMs and PT materials: Creatinine in human serum

    NASA Astrophysics Data System (ADS)

    Camara, Johanna E.; Duewer, David L.; Gasca Aragon, Hugo; Lippa, Katrice A.; Toman, Blaza

    2013-01-01

    The 2009 CCQM-K80 'Comparison of value-assigned CRMs and PT materials: creatinine in human serum' is the first in a series of key comparisons directly testing the chemical measurement services provided to customers by National Metrology Institutes (NMIs) and Designated Institutes. CCQM-K80 compared the assigned serum creatinine values of certified reference materials (CRMs) using measurements made on these materials under repeatability conditions. Six NMIs submitted 17 CRM materials for evaluation, all intended for sale to customers. These materials represent nearly all of the higher-order CRMs then available for this clinically important measurand. The certified creatinine mass fraction in the materials ranged from 3 mg/kg to 57 mg/kg. All materials were stored and prepared according the specifications provided by each NMI. Samples were processed and analyzed under repeatability conditions by one analyst using isotope dilution liquid chromatography-mass spectrometry. The instrumental repeatability imprecision, expressed as a percent relative standard deviation, was 1.2%. Given the number of materials and the time required for each analysis, the measurements were made in two measurement campaigns ('runs'). In both campaigns, replicate analyses (two injections of one preparation separated in time) were made on each of two or three independently prepared aliquots from one randomly selected unit of each of the 17 materials. The mean value, between-campaign, between-aliquot and between-replicate variance components, standard uncertainty of the mean value, and the number of degrees of freedom associated with the standard uncertainty were estimated using a linear mixed model. Since several of the uncertainties estimated using this traditional frequentist approach were associated with a single degree of freedom, Markov Chain Monte Carlo Bayesian analysis was used to estimate 95% level-of-confidence coverage intervals, U95. Uncertainty-weighted generalized distance regression was used to establish the key comparison reference function (KCRF) relating the assigned values to the repeatability measurements. Parametric bootstrap Monte Carlo was used to estimate 95% level-of-confidence coverage intervals for the degrees of equivalence of materials, d +/- U95(d), and of the participating NMIs, D +/- U95(D). Because of the wide range of creatinine mass fraction in the materials, these degrees of equivalence are expressed in percent relative form: %d +/- U95(%d) and %D +/- U95(%D). On the basis of leave-one-out cross-validation, the assigned values for 16 of the 17 materials were deemed equivalent at the 95% level of confidence. These materials were used to define the KCRF. The excluded material was identified as having a marginally underestimated assigned uncertainty, giving it large and potentially anomalous influence on the KCRF. However, this material's %d of 1.4 +/- 1.5 indicates that it is equivalent with the other materials at the 95% level of confidence. The median |%d| for all 17 of the materials is 0.3 with a median U95(%d) of 1.9. All of these higher-order CRMs for creatinine in human serum are equivalent within their assigned uncertainties. The median |%D| for the participating NMIs is 0.3 with a median U95(%D) of 2.1. These results demonstrate that all participating NMIs have the ability to correctly value-assign CRMs and proficiency test materials for creatinine in human serum and similar measurands. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  17. Identification of suitable reference gene and biomarkers of serum miRNAs for osteoporosis

    PubMed Central

    Chen, Jian; Li, Kai; Pang, Qianqian; Yang, Chao; Zhang, Hongyu; Wu, Feng; Cao, Hongqing; Liu, Hongju; Wan, Yumin; Xia, Weibo; Wang, Jinfu; Dai, Zhongquan; Li, Yinghui

    2016-01-01

    Our objective was to identify suitable reference genes in serum miRNA for normalization and screen potential new biomarkers for osteoporosis diagnosis by a systematic study. Two types of osteoporosis models were used like as mechanical unloading and estrogen deficiency. Through a large-scale screening using microarray, qPCR validation and statistical algorithms, we first identified miR-25-3p as a suitable reference gene for both type of osteoporosis, which also showed stability during the differentiation processes of osteoblast and osteoclast. Then 15 serum miRNAs with differential expression in OVX rats were identified by microarray and qPCR validation. We further detected these 15 miRNAs in postmenopausal women and bedrest rhesus monkeys and evaluated their diagnostic value by ROC analysis. Among these miRNAs, miR-30b-5p was significantly down-regulated in postmenopausal women with osteopenia or osteoporosis; miR-103-3p, miR-142-3p, miR-328-3p were only significantly decreased in osteoporosis. They all showed positive correlations with BMD. Except miR328-3p, the other three miRNAs were also declined in the rhesus monkeys after long-duration bedrest. Their AUC values (all >0.75) proved the diagnostic potential. Our results provided a reliable normalization reference gene and verified a group of circulating miRNAs as non-invasive biomarkers in the detection of postmenopausal- and mechanical unloading- osteoporosis. PMID:27821865

  18. Evaluation of factors related to bone disease in Polish children and adolescents with cystic fibrosis.

    PubMed

    Sands, Dorota; Mielus, Monika; Umławska, Wioleta; Lipowicz, Anna; Oralewska, Beata; Walkowiak, Jarosław

    2015-09-01

    The aim of the study was to evaluate factors related to bone formation and resorption in Polish children and adolescents with cystic fibrosis and to examine the effect of nutritional status, biochemical parameters and clinical status on bone mineral density. The study group consisted of 100 children and adolescents with cystic fibrosis with a mean age 13.4 years old. Anthropometric measurements, included body height, body mass and body mass index (BMI); bone mineral densitometry and biochemical testing were performed. Bone mineral density was measured using a dual-energy X-ray absorption densitometer. Biochemical tests included serum calcium, phosphorus, parathyroid hormone and vitamin D concentrations, as well as 24-h urine calcium and phosphorus excretion. Pulmonary function was evaluated using FEV1%, and clinical status was estimated using the Shwachman-Kulczycki score. Standardized body height, body mass and BMI were significantly lower than in the reference population. Mean serum vitamin D concentration was decreased. Pulmonary disease was generally mild, with a mean FEV1% of 81%. Multivariate linear regression revealed that the only factors that had a significant effect on bone marrow density were BMI and FEV1%. There were no significant correlations between bone mineral density and the results of any of the biochemical tests performed. Nutritional status and bone mineral density were significantly decreased in children and adolescents with cystic fibrosis. In spite of abnormalities in biochemical testing, the factors that were found to have the strongest effect on bone mineral density were standardized BMI and clinical status. Copyright © 2015. Published by Elsevier Urban & Partner Sp. z o.o.

  19. Quantification of hepatitis B surface antigen with the novel DiaSorin LIAISON XL Murex HBsAg Quant: correlation with the ARCHITECT quantitative assays.

    PubMed

    Burdino, Elisa; Ruggiero, Tina; Proietti, Alex; Milia, Maria Grazia; Olivero, Antonella; Caviglia, Gian Paolo; Marietti, Milena; Rizzetto, Mario; Smedile, Antonina; Ghisetti, Valeria

    2014-08-01

    Recent technologic innovations allow for quantitative assessment of hepatitis B surface antigen (HBsAg) levels in serum; this has been used to monitor the course of chronic HBV hepatitis (CHB) and predict treatment response. LIAISON-XL Murex HBsAg Quant assay (DiaSorin, Saluggia, I) is the newest immunoassay CE approved to quantify HBsAg. To compare LIAISON-XL performances with ARCHITECT-QT HBsAg (Abbott Diagnostics, IL, USA), as reference test. Sequential serum samples (n=152) from 14 HBe-negative patients with CHB, the majority of them infected by HBV genotype D undergoing antiviral treatment, were retrospectively tested with both assays. The 2nd WHO Standard 00/588 for HBsAg was used as reference. LIAISON-XL and ARCHITECT-QT correlated by r=0.95, p<0.0001; by Bland-Altman analysis agreement of mean difference was 0.21 ± 0.15 log 10 IU/mL, 95% CI: -0.07 to 0.5). Performance of LIAISON-XL against the 2nd WHO Standard was r=0.998, p<0.0001 (95% CI: 0.993-0.999) with results nearer to the expected WHO values compared to ARCHITECT-QT. Median baseline HBsAg level was similar with the two methods before antiviral treatment, throughout fluctuations of HBsAg level in treatment non-responders and during the decrease of HBsAg titer in treatment responders. Correlation between HBsAg levels and HBV DNA was statistically significant for both the two immunoassays (LIAISON-XL: r=0.4988, 95% CI: 0.3452-0.6264, p<0.0001; ARCHITECT-QT: r=0.480, 95% CI: 0.3233-0.6111, p<0.0001). Correlation between HBsAg measurement with LIAISON-XL and ARCHITECT-QT was high. LIAISON-XL accurately quantified HBsAg in clinical samples at baseline or during antiviral therapy; it can be applied for HBsAg quantification in clinical practice and decision making in CHB. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Reference measurement procedure for the determination of electrolytes in human blood via ICP-OES measurement

    NASA Astrophysics Data System (ADS)

    Grote-Koska, D.; Klauke, R.; Brand, K.; Schumann, G.

    2018-04-01

    The determination of electrolytes in human body fluids is one of the most frequently performed analyses in clinical routine laboratories. Metrological traceability of measurement results in patient samples is essential and requires the involvement of higher order reference measurement procedures wherever available. Here, the authors present the evaluation of a higher order reference system for the simultaneous determination of K+, Li+, Na+, Ca2+ and Mg2+ in blood serum and plasma. In the same order, the determined measurement performances were as follows: measurement ranges: 0.75 mmol l-1-75.0 mmol l-1, 0.05 mmol l-1-5.00 mmol l-1, 5 mmol l-1-200 mmol l-1, 0.4 mmol l-1-8.0 mmol l-1 and 0.1 mmol l-1-4.0 mmol l-1. Measurement imprecision: CVs were  ⩽1.1% for intra assay investigations and  ⩽1.8% for long term inter assay investigations for all measurands. Excellent accuracy was found testing certified Standard Reference Materials from NIST: SRM 909 (deviations from 0.0% to 1.1%) and SRM 956 (deviations from 0.0% to 1.5%). Intercomparisons with the German Metrology Institute (PTB) revealed differences from 0.1% to 0.8%. Matrix influences and carry over were not detectable. The expanded combined measurement uncertainties for the determination of the reference method values were estimated as  ⩾1.5% (k  =  2) for each measurand. The reference measurement procedure is accredited by the German accreditation body (DAkkS) in association with the German calibration service (DKD) according to ISO 17025 and ISO 15195. Services comprise the certification of calibrators, control materials and samples used in proficiency testing schemes.

  1. [Standards, options, and recommendations for initial management of patients with malignant ovarian epithelial tumors].

    PubMed

    Kerbrat, P; Lhommé, C; Fervers, B; Guastalla, J P; Thomas, L; Basuyau, J P; Duvillard, P; Cohen-Solal, C; Dauplat, J; Tournemaine, N

    2000-12-09

    Suprapubic and transvaginal pelvic ultrasound exploration is indicated for suspected ovarian tumor (standard). Diagnosis and search for extension require surgery and pathology examination. Systematic preoperative computed tomography is not recommended (standard). Surgery for cancer of the ovary is a specialized procedure requiring skill in cancer, gynecology, visceral surgery and laparoscopic surgery. If the patient is referred to a specialized center after a primary procedure considered to be inadequate, a new procedure is recommended for staging. Residual tumor volume after the primary procedure has prognostic value. Systematic second look procedures are not recommended for routine practice (standard). For patients with grade IA G1 tumors, there is no indication for complementary treatment (standard). For patients with grade IA G2-3 or clear cell tumors, IB, IC, IIA, there is no standard. no complementary treatment, complementary chemotherapy using platinum, complementary external abdominopelvic radiotherapy. A complementary treatment is recommended for grades IC and IIA. Complementary treatment for grades IIB (no residual tissue), IIC (with residual tissue), III (no residual tissue), is based on: complementary chemotherapy with platinium, complementary external abdominopelvic radiotherapy (options). Complementary treatment for advanced forms (IIB (with residual tissue), IIC (with residual tissue), III (with residual tissue) and IV) is based on polychemotherapy with platinium (standard). platinium combined with paclitaxel (intravenous), platinium combined with cyclophosphamide and/or doxorubicin (intravenous) or intraperitoneal cisplatin combined with cyclophosphamide (intravenous). The chemotherapy work-up includes physical examination, assay of serum markers (particularly CA125) and abdominopelvic computed tomography (proof level B) (standard). Physical examination is recommended for monitoring patients in complete remission with no sign of suspected recurrence (standard). This document was reviewed in April 1977. The working group again validated the Standards, OPTIONS and Recommendations, without modifications in June 1999.

  2. Haematological values in pregnant women in Port Harcourt, Nigeria II: Serum iron and transferrin, total and unsaturated iron binding capacity and some red cell and platelet indices.

    PubMed

    Amah-Tariah, F S; Ojeka, S O; Dapper, D V

    2011-12-20

    Previous studies on the normal values of serum iron, unsaturated iron binding capacity, total iron binding capacity, serum transferrin, percent transferrin saturation, red cell distribution width, and various platelet indices: Platelet count, mean platelet volume, platelet distribution width, plateletcrit and platelet larger cell ratio in pregnant subjects in Nigeria are relatively scanty. Present study aims to determine the values of these parameters in apparently healthy pregnant subjects residing in Port Harcourt south eastern Nigeria; and help establish normal reference ranges of these parameters for the population under reference. Cross sectional prospective study involving 220 female subjects attending for the first time, the ante-natal clinics of a tertiary health care facility in Port Harcourt. Subjects were divided into 73, 75 and 72 subjects in the first, second and third trimester of pregnancy respectively. Serum iron and unsaturated iron binding capacity, red cell distribution width, platelet count and platelet distribution width were determined by automated methods; total iron binding capacity, serum transferrin concentrations, percent transferrin saturation, mean platelet volume and plateletcrit were calculated using appropriate formulas. The values of serum iron, unsaturated iron binding capacity, total iron binding capacity and serum transferrin concentrations were found to show significant variations between the various trimesters of pregnancy. However, while serum iron showed significant decreases during pregnancy; unsaturated iron binding capacity, total iron binding capacity and serum transferrin concentrations were found to show significant increases during pregnancy amongst our subjects (p<0.05). By contrast the values of red cell distribution width, platelet count, mean platelet volume, platelet distribution width, plateletcrit and platelet larger cell ratio did not show any significant differences at the different trimesters of pregnancy in our subjects (p>0.05). The present study reports, for the first time, normative values for these parameters in apparently healthy pregnant subjects in Port Harcourt south eastern Nigeria. Apparently, increases in unsaturated and total iron binding capacity and serum transferrin values seen amongst our subjects with increasing gestation may perhaps be a mechanism to ensure a fetal adequate iron delivery on account of the decreasing serum iron concentration with gestation in our subjects. The study suggests that values of serum transferrin are perhaps a more useful screening tool for iron deficiency anemia during pregnancy amongst our subjects.

  3. Reference values for serum ferritin and percentage of transferrin saturation in Korean children and adolescents.

    PubMed

    Oh, Hea Lin; Lee, Jun Ah; Kim, Dong Ho; Lim, Jung Sub

    2018-03-01

    Ferritin reference values vary by age, gender, and ethnicity. We aimed to determine reference values of serum ferritin (SF) and the percentage of transferrin saturation (TSAT) for Korean children and adolescents. We analyzed data from 2,487 participants (1,311 males and 1,176 females) aged 10-20 years from the Korea National Health and Nutrition Examination Survey (2010-2012). We calculated age- and gender-stratified means and percentile values for SF and TSAT. We first plotted mean SF and TSAT by gender and according to age. In males, mean SF tended to be relatively constant among participants aged 10 to 14 years, with an upward trend thereafter. Mean SF trended downward among female participants until the age of 15 years and remained constant thereafter. Thus, significant gender differences in ferritin exist from the age of 14 years. High levels of SF were associated with obesity, and lower SF levels were associated with anemia and menarche status. We established reference values of SF and TSAT according to age and gender. The reference values for SF calculated in this study can be used to test the association between SF values and other defined diseases in Korean children and adolescents.

  4. Reference intervals and diagnostic ranges for serum free κ and free λ immunoglobulin light chains vary by instrument platform: Implications for classification of patient results in a multi-center study.

    PubMed

    Cotten, Steven W; Shajani-Yi, Zahra; Cervinski, Mark A; Voorhees, Timothy; Tuchman, Sascha A; Korpi-Steiner, Nichole

    2018-06-06

    Serum free light chain (FLC) immunoglobulins are key biomarkers that aid in the diagnosis, prognosis and assessment of treatment response in patients with plasma cell disorders (PCD). Here we investigated the transference of manufacturer's reported κFLC, λFLC and κ to λ FLC reference intervals (RI) and established de novo FLC RI and diagnostic ranges on four instruments at three academic medical centers. In addition, we also compared the classification of patient FLC results using manufacturer's versus established RIs and diagnostic ranges. CLSI EP28-A3C protocol was applied to investigate transference and establishment of FLC reference intervals on the cobas (Roche), Immage (Beckman), Optilite and SPA Plus (Binding Site). Serum κ FLC and λ FLC were measured in reference sera (N = 126) with estimation of central 95% RIs and FLC ratio diagnostic range (total range). Frequencies (%) in patient FLC results (N > 380 per institution) classified above, below or within manufacturer's versus established FLC RI were compared. Three of four instrument platforms did not exhibit acceptable transference of manufacturer's reported κFLC RI. The manufacturer's reported FLC total diagnostic range did not encompass all values observed in reference sera for any of the four platforms evaluated. Established FLC ratio diagnostic ranges reduced the frequency of patient results classified above range for three of four platforms evaluated. Transference of manufacturer's reported FLC RIs may be inappropriate for select instrument platforms. De novo establishment of FLC RIs specific to instrument platform is highly recommended in order to assure correct patient result classification. Copyright © 2017. Published by Elsevier Inc.

  5. Vanadium release in whole blood, serum and urine of patients implanted with a titanium alloy hip prosthesis.

    PubMed

    Catalani, S; Stea, S; Beraudi, A; Gilberti, M E; Bordini, B; Toni, A; Apostoli, P

    2013-08-01

    Vanadium (V) is a minor constituent of the Titanium-Aluminum-Vanadium (TiAlV) alloy currently used in cementless hip prostheses. Present study aimed at verifying the correlation of vanadium levels among different matrices and assessing reference levels of the ion in a population of patients wearing a well-functioning hip prosthesis. Vanadium was measured using Inductive Coupled Plasma Mass Spectrometry (ICP-MS) in whole blood, serum and urine of 129 patients implanted with a TiAlV-alloy hip prosthesis. The values in the serum were above the upper limit of the reference values in 42% of patients (29% in urine and 13% in whole blood). A good correlation among matrices was observed (p < 0.001). The cohort of patients (N = 32) complaining of pain or in which a loosening or damage to the prosthesis was assessed showed a significantly higher excretion of vanadium in urine as compared with the remaining asymptomatic patients (p = 0.001). The 95th percentile distribution of vanadium in the cohort of patients with a well-functioning prosthesis was 0.3 μg/L in whole blood, 0.5 μg/L in serum and 2.8 μg/L in urine, higher that in the unexposed population, especially for urine. The presence of a prosthesis, even though well-functioning, may cause a possible release of vanadium into the blood and a significant urinary excretion. The reference values of vanadium of the asymptomatic patients with titanium alloy hip prostheses supplied information regarding the background exposure level of the ions and their lower and upper limits.

  6. STUDIES ON DECREASING THE REACTION OF NORMAL SKIN TO DESTRUCTIVE DOSES OF X-RAYS BY PHARMACOLOGICAL MEANS AND ON THE MECHANISM INVOLVED

    PubMed Central

    Auer, John; Witherbee, William D.

    1921-01-01

    When a fixed area of the ears of rabbits is subjected to the action of a standard destructive dose of x-rays (30 skin units) the type of reaction resulting depends upon the previous treatment of the rabbit. (1) In normal rabbits a mild acute inflammation develops in the x-rayed area which leads at once to a perforating gangrene within an average of 15 days. (2) If rabbits are x-rayed and about 2 weeks later injected with horse serum for the first time, a mild acute inflammation appears which heals for a time; then a second, subacute inflammation sets in which leads to a perforating gangrene. The average time of the process from the first inflammation to gangrene is 32 days. (3) If rabbits are sensitized with horse serum and 10 days later are exposed locally to the standard dose of x-rays, the ensuing ear reaction is either similar to the second reaction described above, except that it may last up to 110 days, or the first inflammation leads to a healing which may be apparently permanent (340 + days). (4) If rabbits are first sensitized with horse serum, exposed locally to the standard dose of x-rays 10 days later, and 13 days after the x-ray treatment reinjected with horse serum, the reaction of the x-rayed area of the ears is in general similar to the second reaction described above (inflammation—healing—inflammation—gangrene). The average time of the whole process is about 42 days. On the basis of the general hypothesis that an anaphylactic reaction is initiated in the body when the specific antibody meets its antigen, and that both antibody and antigen are rendered more or less functionally inert by their interaction, the following inferences may be drawn from our experimental results. (1) The protection from the effects of a standard destructive dose of x-rays which a previous sensitization confers, is referable to the presence of anaphylactic antibodies in the x-rayed area. (2) This protection is largely due to the anaphylactic antibodies which are anchored in the x-rayed area, and not to those which are free in the circulation. (3) An anaphylactic reaction renders the anchored anaphylactic antibodies largely impotent as protective factors against the standard destructive x-ray dose, even though sensitization preceded exposure to the x-rays. (4) An area treated with the standard destructive dose of x-rays is unable to produce or to anchor a sufficient amount of anaphylactic antibodies for protection from necrosis, when the x-ray treatment precedes the sensitization, or when the locally anchored anaphylactic antibodies are rendered functionally inactive by a general anaphylactic reaction. It is possible that the procedure of increasing the resistance of the skin to a destructive dose of x-rays by means of a previous sensitization with protein may be applicable in the treatment of certain types of inoperable disease, when it is important to use massive doses of x-rays. Animals which have been sensitized, or sensitized and reinjected with any undenatured alien protein, should not be reemployed as normal controls in any investigation unless trial has shown that these proteinized animals react quantitatively and qualitatively like normal animals. The presence of an abnormal reactor in a group of supposedly normal animals may be an indication of a previous proteinization. PMID:19868536

  7. Reference Intervals for Preprandial and Postprandial Serum Bile Acid in Adult Rhesus Macaques (Macaca mulatta)

    PubMed Central

    Lemoy, Marie-Josee MF; Westworth, Diccon R; Ardeshir, Amir; Tarara, Ross P

    2013-01-01

    The purpose of this study was to determine the 12-h fasting preprandial and 2-h postprandial serum bile acid concentration (SBAC) reference intervals for healthy, adult rhesus macaques (Macaca mulatta). We hypothesized that the mean 2-h postprandial SBAC would be significantly higher than the mean preprandial SBAC. We included 40 (24 male, 16 female) macaques after confirming that their health records, physical examinations, CBC, serum chemistry panels, and urinalyses were all within normal limits. In addition, hepatitis A titers were determined, an ultrasound examination of the liver was performed, and two 16-gauge ultrasound guided percutaneous liver biopsies were collected and submitted for histopathology. Macaques were confirmed healthy according to hepatitis A screens and sonographic and histologic evaluation of hepatic tissue. Within 2 wk of the screening procedures, preprandial and postprandial SBACs were measured. Preprandial SBAC (mean ± 1 SD) was 11.1 ± 1.9 µmol/L and postprandial SBAC was 19.7 ± 8.0 µmol/L, which was significantly higher than the preprandial value. Sex and hepatitis titers did not significantly influence preprandial and postprandial SBAC. The current study indicates that the SBAC reference values for rhesus macaques are higher than those reported for humans and companion animals. PMID:23849441

  8. Reference intervals for preprandial and postprandial serum bile acid in adult rhesus macaques (Macaca mulatta).

    PubMed

    Lemoy, Marie-Josee M F; Westworth, Diccon R; Ardeshir, Amir; Tarara, Ross P

    2013-07-01

    The purpose of this study was to determine the 12-h fasting preprandial and 2-h postprandial serum bile acid concentration (SBAC) reference intervals for healthy, adult rhesus macaques (Macaca mulatta). We hypothesized that the mean 2-h postprandial SBAC would be significantly higher than the mean preprandial SBAC. We included 40 (24 male, 16 female) macaques after confirming that their health records, physical examinations, CBC, serum chemistry panels, and urinalyses were all within normal limits. In addition, hepatitis A titers were determined, an ultrasound examination of the liver was performed, and two 16-gauge ultrasound guided percutaneous liver biopsies were collected and submitted for histopathology. Macaques were confirmed healthy according to hepatitis A screens and sonographic and histologic evaluation of hepatic tissue. Within 2 wk of the screening procedures, preprandial and postprandial SBACs were measured. Preprandial SBAC (mean ± 1 SD) was 11.1 ± 1.9 μmol/L and postprandial SBAC was 19.7 ± 8.0 μmol/L, which was significantly higher than the preprandial value. Sex and hepatitis titers did not significantly influence preprandial and postprandial SBAC. The current study indicates that the SBAC reference values for rhesus macaques are higher than those reported for humans and companion animals.

  9. Reference values of blood parameters in beef cattle of different ages and stages of lactation.

    PubMed Central

    Doornenbal, H; Tong, A K; Murray, N L

    1988-01-01

    Reference (normal) values for 12 blood serum components were determined for 48 Shorthorn cows (2-10 years old) and their 48 calves, 357 crossbred cows (12-14 years old), 36 feedlot bulls and 36 feedlot steers. In addition, hemoglobin, hematocrit, triiodothyronine, thyroxine and cortisol levels were determined for the crossbred cows, and feedlot bulls and steers. Reference values were tabulated according to sex, age and stage of lactation. Serum concentrations of urea, total protein and bilirubin, and serum activity of aspartate aminotransferase and lactate dehydrogenase increased with age (P less than 0.05), while calcium, phosphorus and alkaline phosphatase decreased with age (P less than 0.05) from birth to the age of ten years. The Shorthorn cows had the highest levels of glucose at parturition (P less than 0.05) with decreasing levels during lactation. Creatinine concentration decreased during lactation and increased during postweaning. Both lactate dehydrogenase and aspartate aminotransferase levels increased (P less than 0.05) during lactation. Urea and uric acid were present at higher concentrations in lactating than nonlactating cows (P less than 0.05). The values reported, based on a wide age range and large number of cattle, could serve as clinical guides and a basis for further research. PMID:3349406

  10. Simultaneous determination of creatinine and creatine in human serum by double-spike isotope dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS) and gas chromatography-mass spectrometry (GC-MS).

    PubMed

    Fernández-Fernández, Mario; Rodríguez-González, Pablo; Añón Álvarez, M Elena; Rodríguez, Felix; Menéndez, Francisco V Álvarez; García Alonso, J Ignacio

    2015-04-07

    This work describes the first multiple spiking isotope dilution procedure for organic compounds using (13)C labeling. A double-spiking isotope dilution method capable of correcting and quantifying the creatine-creatinine interconversion occurring during the analytical determination of both compounds in human serum is presented. The determination of serum creatinine may be affected by the interconversion between creatine and creatinine during sample preparation or by inefficient chemical separation of those compounds by solid phase extraction (SPE). The methodology is based on the use differently labeled (13)C analogues ((13)C1-creatinine and (13)C2-creatine), the measurement of the isotopic distribution of creatine and creatinine by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and the application of multiple linear regression. Five different lyophilized serum-based controls and two certified human serum reference materials (ERM-DA252a and ERM-DA253a) were analyzed to evaluate the accuracy and precision of the proposed double-spike LC-MS/MS method. The methodology was applied to study the creatine-creatinine interconversion during LC-MS/MS and gas chromatography-mass spectrometry (GC-MS) analyses and the separation efficiency of the SPE step required in the traditional gas chromatography-isotope dilution mass spectrometry (GC-IDMS) reference methods employed for the determination of serum creatinine. The analysis of real serum samples by GC-MS showed that creatine-creatinine separation by SPE can be a nonquantitative step that may induce creatinine overestimations up to 28% in samples containing high amounts of creatine. Also, a detectable conversion of creatine into creatinine was observed during sample preparation for LC-MS/MS. The developed double-spike LC-MS/MS improves the current state of the art for the determination of creatinine in human serum by isotope dilution mass spectrometry (IDMS), because corrections are made for all the possible errors derived from the sample preparation step.

  11. Diagnostic-test evaluation of immunoassays for anti-Toxoplasma gondii IgG antibodies in a random sample of Mexican population.

    PubMed

    Caballero-Ortega, Heriberto; Castillo-Cruz, Rocío; Murieta, Sandra; Ortíz-Alegría, Luz Belinda; Calderón-Segura, Esther; Conde-Glez, Carlos J; Cañedo-Solares, Irma; Correa, Dolores

    2014-05-14

    There are few articles on evaluation of Toxoplasma gondii serological tests. Besides, commercially available tests are not always useful and are expensive for studies in open population. The aim of this study was to evaluate in-house ELISA and western blot for IgG antibodies in a representative sample of people living in Mexico. Three hundred and five serum samples were randomly selected from two national seroepidemiological survey banks; they were taken from men and women of all ages and from all areas of the country. ELISA cut-off was established using the mean plus three standard deviations of negative samples. Western blots were analysed by two experienced technicians and positivity was established according to the presence of at least three diagnostic bands. A commercial ELISA kit was used as a third test. Two reference standards were built up: one using concordant results of two assays leaving the evaluated test out and the other in which the evaluated test was included (IN) with at least two concordant results to define diagnosis. the lowest values of diagnostic parameters were obtained with the OUT reference standards: in-house ELISA had 96.9% sensitivity, 62.1% specificity, 49.6% PPV, 98.1% NPV and 71.8% accuracy, while western blot presented 81.8%, 89.7%, 84.0%, 88.2% and 86.6% values and the best kappa coefficient (0.72-0.82). The in-house ELISA is useful for screening people of Mexico, due to its high sensitivity, while western blot may be used to confirm diagnosis. These techniques might prove useful in other Latin American countries.

  12. Activin B is a novel biomarker for chronic fatigue syndrome/myalgic encephalomyelitis (CFS/ME) diagnosis: a cross sectional study.

    PubMed

    Lidbury, Brett A; Kita, Badia; Lewis, Donald P; Hayward, Susan; Ludlow, Helen; Hedger, Mark P; de Kretser, David M

    2017-03-16

    Investigations of activin family proteins as serum biomarkers for chronic fatigue syndrome/myalgic encephalomyelitis (CFS/ME). CFS/ME is a disease with complex, wide-ranging symptoms, featuring persistent fatigue of 6 months or longer, particularly post exertion. No definitive biomarkers are available. A cross-sectional, observational study of CFS/ME patients fulfilling the 2003 Canadian Consensus Criteria, in parallel with healthy non-fatigued controls, was conducted. Comparisons with a previously defined activin reference population were also performed. For the total study cohort the age range was 18-65 years with a female: male participant ratio of greater than 3:1. All participants were assessed via a primary care community clinic. Blood samples were collected for pathology testing after physical examination and orthostatic intolerance assessment. Cytokines, activin A, activin B and follistatin were also measured in sera from these samples. All data were compared between the CFS/ME and control cohorts, with the activins and follistatin also compared with previously defined reference intervals. Serum activin B levels for CFS/ME participants were significantly elevated when compared to the study controls, as well as the established reference interval. Serum activin A and follistatin were within their normal ranges. All routine and special pathology markers were within the normal laboratory reference intervals for the total study cohort, with no significant differences detected between CFS/ME and control groups. Also, no significant differences were detected for IL-2, IL-4, IL-6, IL-10, IL-17A, TNF or IFN-gamma. Elevated activin B levels together with normal activin A levels identified patients with the diagnostic symptoms of CFS/ME, thus providing a novel serum based test. The activins have multiple physiological roles and capture the diverse array of symptoms experienced by CFS/ME patients.

  13. Co-infections with Chikungunya and Dengue Viruses, Guatemala, 2015.

    PubMed

    Edwards, Thomas; Signor, Leticia Del Carmen Castillo; Williams, Christopher; Donis, Evelin; Cuevas, Luis E; Adams, Emily R

    2016-11-01

    We screened serum samples referred to the national reference laboratory in Guatemala that were positive for chikungunya or dengue viruses in June 2015. Co-infection with both viruses was detected by reverse transcription PCR in 46 (32%) of 144 samples. Specimens should be tested for both arboviruses to detect co-infections.

  14. Opsonic and protective activity of immunoglobulin, modified immunoglobulin, and serum against neonatal Escherichia coli K1 infection.

    PubMed

    Bortolussi, R; Fischer, G W

    1986-02-01

    Because modified immune serum globulin (M-ISG) has been proposed for therapy in neonatal bacterial sepsis, we evaluated it in a suckling rat model of Escherichia coli K1 sepsis. We compared a M-ISG preparation (lot 2581), which was protective against group B streptococcal (GBS) sepsis, with other M-ISG, standard ISG preparations and with adult and cord serum. All immune serum preparations and sera demonstrated opsonic activity against E. coli K1 and were superior to saline in protecting against death due to E. coli K1 sepsis. Survival rates were higher for one M-ISG preparation (lot 2581) than for randomly selected standard immune serum globulin and cord sera but were similar to adult sera in these protection studies. Therapeutic and opsonic activity of standard immune serum globulin and M-ISG prepared from the same donors were similar, suggesting that the different processes used for their manufacture did not affect these activities. Because the M-ISG preparation studied showed protective activity to both GBS and E. coli K1, we studied it further by adsorbing the preparation with GBS and E. coli K1. Opsonic activity to E. coli K1 was removed by E. coli adsorption but not by adsorption with GBS, indicating that this activity was not due to a single cross-reacting antibody. Empirical therapy with M-ISG prescreened for opsonic activity to both E. coli K1 and GBS may be of clinical value. Trials appear warranted to study the pharmacology and efficacy of M-ISG in septic newborns.

  15. Usefulness of enzyme immunoassay (EIA) for screening of anti HIV antibodies in urinary specimens: A comparative analysis.

    PubMed

    Sahni, A K; Nagendra, A; Roy, Partha; Patrikar, S

    2014-07-01

    Standard HIV testing is done using serum or plasma. FDA approved ELISA to screen urine for IgG antibodies to HIV-1 in 1996. It is a simple, noninvasive test and is appropriate for developing countries where health care personnel may not be professionally trained or where clean needles for drawing blood may not always be available. 436 individuals with high-risk behavior and strong clinical suspicion of HIV infection were screened for IgG antibodies to HIV-1 in urine by ELISA. Urine HIV testing was performed by enzyme immunoassay, at the ongoing Voluntary Confidential Counseling and Testing Center (VCCTC) at a large tertiary care microbiology lab. The individuals enrolled for the study had high-risk exposure to the virus and majorities were from a state with a high incidence of HIV infection. In all individuals, both serum and urine were tested for IgG antibodies to HIV-1. Overall, 135 individuals (30.96%) were HIV-positive, of whom 96 (71%) had never previously tested positive; 87% of those who tested positive received their results, and most were referred for medical care. Sensitivity, specificity and predictive values of HIV-1 urine ELISA test kit were determined. Sensitivity was found to be 89.6%; 95% CI [82.9-94.0], specificity 97.3%; 95% CI [94.6-98.8], positive predictive value 93.8%; 95% CI [87.8-97.1] and negative predictive value 95.4%; 95% CI [92.3-97.4]. Efficiency, sensitivity, and specificity of the urine-based screening for HIV-1 test kits were excellent as compared to the reference test.

  16. ID-SERS Based Reference Method for Quantification of Large Biomolecules on a Single Chip

    NASA Astrophysics Data System (ADS)

    Yaghobian, Fatemeh; Stosch, Rainer; Henrion, André; Güttler, Bernd

    2010-08-01

    Accuracy and precision of quantitative SERS results have been significantly increased by applying a method based on the so-called isotope-dilution (ID) principle. In this ID-SERS approach, an isotopically labeled analogue of the target molecule (isotopologue) is spiked to the sample at a known concentration. Due to the slight difference in their molar masses, some Raman bands of the heavier isotopologue are red-shifted with respect to the same signals resulting from the unlabelled compound. As a result, spectra evaluation is reduced to the determination of intensity ratios rather than absolute intensities, and the unknown quantity of the analyte can be calculated from the known quantity of the standard. This procedure is of particular interest in the development of highly accurate reference procedures for metrology in chemistry. Because the sample is spiked prior to any further treatment, potential loss of material or matrix effects would equally affect both isotopologues, without influencing the final result. The method has been successfully applied for quantifying small diagnostic marker molecules like creatinine at their relevant serum concentration levels using silver colloids as SERS substrates. Now, the ID-SERS approach has been realized as a "one-chip" approach using "Bio-chips" made of intrinsically grown spherical silver nanoparticles with gaps less than 10 nm in between (Fig. 1). In addition, the scope of the method has been extended to larger biomolecules like peptides which will be shown using the example of the human growth-hormone (hGH) peptide T12 at physiologically relevant serum concentration levels (Fig. 2). Further developments towards the quantification of full proteins will also be reported.

  17. Status of serum-calcium and -albumin measurement in Argentina assessed in 300 representative laboratories with 20 fresh frozen single donation sera.

    PubMed

    Stepman, Hedwig C M; Stöckl, Dietmar; Acheme, Rosana; Sesini, Sandra; Mazziotta, Daniel; Thienpont, Linda M

    2011-11-01

    The Fundación Bioquímica Argentina (FBA) performs external quality assessment (EQA) of >3200 laboratories. However, FBA realizes that sample non-commutability and predominant use of heterogeneous systems may bias the estimated performance and standardization status. To eliminate these confounding factors, a study using frozen single donation sera was undertaken with the focus on serum-calcium and -albumin measurement. Target values were established from the results produced with homogeneous systems. In groups of n=7, system effects were investigated. Laboratory performance was evaluated from the correlation coefficient r between the measurement results for all sera and the target values. This allowed ranking of the laboratories and judgment of the deviation for individual samples (total error) against a 10% limit. The total error specification was a deviation for ≥ 5 samples exceeding 10% and/or causing a result outside the laboratory's reference interval. For calcium (n=303) (range: 2.06-2.42 mmol/L), 81 laboratories had an r-value <0.6, 43 even <0.4; the total error was relevant for 97 (10% limit) and 111 (reference interval) laboratories. For albumin (n=311) (range: 34.7-45.7 g/L) r was <0.7 (<0.4) in 44 (16) laboratories; 83 and 36 laboratories exceeded the total error criteria. Laboratories using homogeneous systems were generally ranked higher by correlation. System effects were moderate for calcium, but significant for albumin. The study demonstrated the need to improve the quality and harmonization of calcium and albumin testing in the investigated laboratories. To achieve this objective, we promote co-operation between laboratories, EQA provider and manufacturers.

  18. Microbioassay of Antimicrobial Agents

    PubMed Central

    Simon, Harold J.; Yin, E. Jong

    1970-01-01

    A previously described agar-diffusion technique for microbioassay of antimicrobial agents has been modified to increase sensitivity of the technique and to extend the range of antimicrobial agents to which it is applicable. This microtechnique requires only 0.02 ml of an unknown test sample for assay, and is capable of measuring minute concentrations of antibiotics in buffer, serum, and urine. In some cases, up to a 20-fold increase in sensitivity is gained relative to other published standardized methods and the error of this method is less than ±5%. Buffer standard curves have been established for this technique, concurrently with serum standard curves, yielding information on antimicrobial serum-binding and demonstrating linearity of the data points compared to the estimated regression line for the microconcentration ranges covered by this technique. This microassay technique is particularly well suited for pediatric research and for other investigations where sample volumes are small and quantitative accuracy is desired. Dilution of clinical samples to attain concentrations falling with the range of this assay makes the technique readily adaptable and suitable for general clinical pharmacological studies. The microassay technique has been standardized in buffer solutions and in normal human serum pools for the following antimicrobials: ampicillin, methicillin, penicillin G, oxacillin, cloxacillin, dicloxacillin, cephaloglycin, cephalexin, cephaloridine, cephalothin, erythromycin, rifamycin amino methyl piperazine, kanamycin, neomycin, streptomycin, colistin, polymyxin B, doxycycline, minocycline, oxytetracycline, tetracycline, and chloramphenicol. PMID:4986725

  19. Vibration Therapy Is No More Effective Than the Standard Practice of Massage and Stretching for Promoting Recovery From Muscle Damage After Eccentric Exercise.

    PubMed

    Fuller, Joel T; Thomson, Rebecca L; Howe, Peter R C; Buckley, Jonathan D

    2015-07-01

    The purpose of this study was to determine if vibration therapy is more effective than the standard treatment of stretching and massage for improving recovery of muscle strength and reducing muscle soreness after muscle damage induced by eccentric exercise. A randomized, single-blinded parallel intervention trial design was used. Research laboratory. Fifty untrained men aged 18 to 30 years completed the study. Participants performed 100 maximal eccentric muscle actions (ECCmax) of the right knee extensor muscles. For the next 7 days, 25 participants applied cycloidal vibration therapy to the knee extensors twice daily and 25 participants performed stretching and sports massage (SSM) twice daily. Changes in markers of muscle damage [peak isometric torque (PIT), serum creatine kinase (CK), and serum myoglobin (Mb)], muscle soreness (visual analog scale), and inflammation [serum C-reactive protein (CRP)] were assessed. After ECCmax, there was no difference in recovery of PIT and muscle soreness or serum CK, Mb, and CRP levels between vibration and SSM groups (P > 0.28). Cycloidal vibration therapy is no more effective than the standard practice of stretching and massage to promote muscle recovery after the performance of muscle-damaging exercise. Prescription of vibration therapy after maximal exercise involving eccentric muscle damage did not alleviate signs and symptoms of muscle damage faster than the standard prescription of stretching and massage.

  20. Bovine serum albumin-Cu(II) hybrid nanoflowers: An effective adsorbent for solid phase extraction and slurry sampling flame atomic absorption spectrometric analysis of cadmium and lead in water, hair, food and cigarette samples.

    PubMed

    Yilmaz, Erkan; Ocsoy, Ismail; Ozdemir, Nalan; Soylak, Mustafa

    2016-02-04

    Herein, the synthesis of bovine serum albumin-Cu(II) hybrid nanoflowers (BSA-NFs) through the building blocks of bovine serum albumin (BSA) and copper(II) ions in phosphate buffered saline (PBS) and their use as adsorbent for cadmium and lead ions are reported. The BSA-NFs, for the first time, were efficiently utilized as novel adsorbent for solid phase extraction (SPE) of cadmium and lead ions in water, food, cigarette and hair samples. The method is based on the separation and pre-concentration of Cd(II) and Pb(II) by BSA-NFs prior to determination by slurry analysis via flame atomic absorption spectrometry (FAAS). The analytes were adsorbed on BSA-NFs under the vortex mixing and then the ion-loaded slurry was separated and directly introduced into the flame AAS nebulizer by using a hand-made micro sample introduction system to eliminate a number of drawbacks. The effects of analytical key parameters, such as pH, amount of BSA-NFs, vortexing time, sample volume, and matrix effect of foreign ions on adsorbing of Cd(II) and Pb(II) were systematically investigated and optimized. The limits of detection (LODs) for Cd(II) and Pb(II) were calculated as 0.37 μg L(-)(1) and 8.8 μg L(-)(1), respectively. The relative standard deviation percentages (RSDs) (N = 5) for Cd(II) and Pb(II) were 7.2%, and 5.0%, respectively. The accuracy of the developed procedure was validated by the analysis of certified reference materials (TMDA-53.3 Fortified Water, TMDA-70 Fortified Water, SPS-WW2 Waste Water, NCSDC-73349 Bush Branches and Leaves) and by addition/recovery analysis. The quantitative recoveries were obtained for the analysis of certified reference materials and addition/recovery tests. The method was successfully applied to the analysis of cadmium and lead in water, food, cigarette and hair samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Determination of serum aluminum by electrothermal atomic absorption spectrometry: A comparison between Zeeman and continuum background correction systems

    NASA Astrophysics Data System (ADS)

    Kruger, Pamela C.; Parsons, Patrick J.

    2007-03-01

    Excessive exposure to aluminum (Al) can produce serious health consequences in people with impaired renal function, especially those undergoing hemodialysis. Al can accumulate in the brain and in bone, causing dialysis-related encephalopathy and renal osteodystrophy. Thus, dialysis patients are routinely monitored for Al overload, through measurement of their serum Al. Electrothermal atomic absorption spectrometry (ETAAS) is widely used for serum Al determination. Here, we assess the analytical performances of three ETAAS instruments, equipped with different background correction systems and heating arrangements, for the determination of serum Al. Specifically, we compare (1) a Perkin Elmer (PE) Model 3110 AAS, equipped with a longitudinally (end) heated graphite atomizer (HGA) and continuum-source (deuterium) background correction, with (2) a PE Model 4100ZL AAS equipped with a transversely heated graphite atomizer (THGA) and longitudinal Zeeman background correction, and (3) a PE Model Z5100 AAS equipped with a HGA and transverse Zeeman background correction. We were able to transfer the method for serum Al previously established for the Z5100 and 4100ZL instruments to the 3110, with only minor modifications. As with the Zeeman instruments, matrix-matched calibration was not required for the 3110 and, thus, aqueous calibration standards were used. However, the 309.3-nm line was chosen for analysis on the 3110 due to failure of the continuum background correction system at the 396.2-nm line. A small, seemingly insignificant overcorrection error was observed in the background channel on the 3110 instrument at the 309.3-nm line. On the 4100ZL, signal oscillation was observed in the atomization profile. The sensitivity, or characteristic mass ( m0), for Al at the 309.3-nm line on the 3110 AAS was found to be 12.1 ± 0.6 pg, compared to 16.1 ± 0.7 pg for the Z5100, and 23.3 ± 1.3 pg for the 4100ZL at the 396.2-nm line. However, the instrumental detection limits (3 SD) for Al were very similar: 3.0, 3.2, and 4.1 μg L - 1 for the Z5100, 4100ZL, and 3110, respectively. Serum Al method detection limits (3 SD) were 9.8, 6.9, and 7.3 μg L - 1 , respectively. Accuracy was assessed using archived serum (and plasma) reference materials from various external quality assessment schemes (EQAS). Values found with all three instruments were within the acceptable EQAS ranges. The data indicate that relatively modest ETAAS instrumentation equipped with continuum background correction is adequate for routine serum Al monitoring.

  2. Eddy-Current Reference Standard

    NASA Technical Reports Server (NTRS)

    Ambrose, H. H., Jr.

    1985-01-01

    Magnetic properties of metallic reference standards duplicated and stabilized for eddy-current coil measurements over long times. Concept uses precisely machined notched samples of known annealed materials as reference standards.

  3. A systematic review and meta-analysis of the diagnostic accuracy of point-of-care tests for the detection of hyperketonemia in dairy cows.

    PubMed

    Tatone, Elise H; Gordon, Jessica L; Hubbs, Jessie; LeBlanc, Stephen J; DeVries, Trevor J; Duffield, Todd F

    2016-08-01

    Several rapid tests for use on farm have been validated for the detection of hyperketonemia (HK) in dairy cattle, however the reported sensitivity and specificity of each method varies and no single study has compared them all. Meta-analysis of diagnostic test accuracy is becoming more common in human medical literature but there are few veterinary examples. The objective of this work was to perform a systematic review and meta-analysis to determine the point-of-care testing method with the highest combined sensitivity and specificity, the optimal threshold for each method, and to identify gaps in the literature. A comprehensive literature search resulted in 5196 references. After removing duplicates and performing relevance screening, 23 studies were included for the qualitative synthesis and 18 for the meta-analysis. The three index tests evaluated in the meta-analysis were: the Precision Xtra(®) handheld device measuring beta-hydroxybutyrate (BHB) concentration in whole blood, and Ketostix(®) and KetoTest(®) semi-quantitative strips measuring the concentration of acetoacetate in urine and BHB in milk, respectively. The diagnostic accuracy of the 3 index tests relative to the reference standard measurement of BHB in serum or whole blood between 1.0-1.4mmol/L was compared using the hierarchical summary receiver operator characteristic (HSROC) method. Subgroup analysis was conducted for each index test to examine the accuracy at different thresholds. The impact of the reference standard threshold, the reference standard method, the prevalence of HK in the population, the primary study source and risk of bias of the primary study was explored using meta-regression. The Precision Xtra(®) device had the highest summary sensitivity in whole blood BHB at 1.2mmol/L, 94.8% (CI95%: 92.6-97.0), and specificity, 97.5% (CI95%: 96.9-98.1). The threshold employed (1.2-1.4mmol/L) did not impact the diagnostic accuracy of the test. The Ketostix(®) and KetoTest(®) strips had the highest summary sensitivity and specificity when the trace and weak positive thresholds were used, respectively. Controlling for the source of publication, HK prevalence and reference standard employed did not impact the estimated sensitivity and specificity of the tests. Including only peer-reviewed studies reduced the number of primary studies evaluating the Precision Xtra(®) by 43% and Ketostix(®) by 33%. Diagnosing HK with blood, urine or milk are valid options, however, the diagnostic inaccuracy of urine and milk should be considered when making economic and treatment decisions. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Rabies vaccine standards: comparison of the 5th and 6th WHO international reference standards to the USDA veterinary reference standard.

    PubMed

    Hermann, J; Fry, A; Reising, M; Patterson, P; Siev, D; Gatewood, D

    2012-11-06

    Ensuring rabies vaccines are potent and effective is paramount in preventing transmission of this deadly disease and safeguarding public health. Efficacy of human and veterinary vaccines is ensured by evaluating relative potency estimates of the vaccine compared to a rabies reference standard using the National Institutes of Health (NIH) test. Reference vaccines are based on the International Standard for Rabies Vaccine provided by the World Health Organization (WHO). A comparison study was conducted to determine the relative potency of the 5th WHO, 6th WHO, and United States Department of Agriculture's (USDA) 08-14 reference standards using the NIH test. Results from the study demonstrate that the 6th WHO reference standard is approximately twice as potent as the 5th WHO reference when reconstituted to contain 1 IU per ml. Based on these results, the Center for Veterinary Biologics (CVB) doubled the reconstitution volume of USDA veterinary reference 08-14 from 13 ml to 26 ml, for an initial use dilution of 0.7 IU per ml for use by veterinary biologics manufacturers in the NIH test. This study emphasizes the importance of reference standard calibration for use in the National Institutes of Health test. Published by Elsevier Ltd.

  5. Body Fatness and Risk for Elevated Blood Pressure, Total Cholesterol, and Serum Lipoprotein Ratios in Children and Adolescents.

    ERIC Educational Resources Information Center

    Williams, Daniel P.; And Others

    1992-01-01

    Examines the relationship between body fat percent and risk for elevated blood pressure, serum total cholesterol, and serum lipoprotein ratios in 1,230 African-American and 2,090 white 5-18 year olds (1,667 males and 1,653 females). Results support body fatness standards in children and adolescents as cardiovascular risk factors. (SLD)

  6. Could the erythrocyte indices or serum ferritin predict the therapeutic response to a trial with oral iron during pregnancy? Results from the Accuracy study for Maternal Anaemia diagnosis (AMA).

    PubMed

    Bresani Salvi, Cristiane Campello; Braga, Maria Cynthia; Figueirôa, José Natal; Batista Filho, Malaquias

    2016-08-12

    Treatment of maternal iron-deficiency anaemia can reduce risks of prematurity and low birth weight; hence a reliable diagnosis of maternal iron needs is critical. However, erythrocyte indices and serum ferritin have shown a weak correlation with iron status during pregnancy. This study verified the accuracy of those tests to predict the responsiveness to a therapeutic test with oral iron as reference standard for iron deficiency in pregnant women. A prospective diagnostic study phase 3 was conducted in a single prenatal care center in Northeast Brazil. Between August 2011 and October 2012 a consecutive sampling included 187 women in their 2(nd)-3(rd) trimesters of low-risk pregnancy and having anaemia (haemoglobin <11.0 g/dL). Until December 2012, 139 women completed a trial with daily pills of ferrous sulfate (40 mg of iron), during 23 to 125 days. Haemoglobin (Hb), other erythrocyte indices and ferritin (index-tests) were assessed pre-treatment by automated analyzers. Hb was performed also post-treatment to assess the therapeutic response by its post-pretreatment differences. We estimated sensitivity (Se), specificity (Sp), predictive values (PV), likelihood ratios (LR), diagnostic Odds Ratio (OR), area under Receiver Operating Characteristic curve (AUC), accuracy ratio and agreement coefficient of the index-tests against an increase of at least 0.55 Hb Z-score (reference standard test). We calculated the Z-scores according to the reference population from Centers for Disease Control and Prevention. Hb had a mean increase of 0.24 Z-score after 30 iron pills (p 0.013). All index-tests demonstrated PV- above 70 %, PV+ around 40 %, LR around 1.0, and AUC of 0.5 to 0.6. Hb and haematocrit had Se of 50 % (95 % CI 40 to 70); and Sp of 59 % (95 % CI 43 to 74) and 47 % (95 % CI 38 to 57), respectively. Ferritin, Mean Corpuscular Volume, Mean Corpuscular Haemoglobin, Mean Corpuscular Haemoglobin Concentration and Red blood cell Distribution Width had Se below 40 % with Sp above 70 %. Erythrocyte indices and ferritin could not predict the iron needs of anemic pregnant women. Increases of Hb Z-scores after a short treatment with oral iron may be a reliable therapeutic test. World Health Organization International Clinical Trials Registry Platform U1111-1123-2605; Brazilian Registry of Clinical Trials RBR-237wbg , registered 28 July 2011.

  7. Validation of serum free light chain reference ranges in primary care.

    PubMed

    Galvani, Luca; Flanagan, Jane; Sargazi, Mansour; Neithercut, William D

    2016-05-01

    The demand for measurement of serum immunoglobulin free kappa (κ) and lambda (λ) light chains has increased. The κ:λ ratio is used to assist in diagnosis/monitoring of plasma cell disorders. The binding site reference range for serum-free light chain κ:λ ratios of 0.26-1.65 was derived from healthy volunteers. Subsequently, a reference range of 0.37-3.1 for patients with chronic kidney disease has been proposed. Elevated free light chain concentrations and borderline raised free light chain ratios also may be found in polyclonal gammopathies and with other non-renal illnesses. This assessment was conducted to validate the established free light chain reference ranges in individuals from primary care. A total of 130 samples were identified from routine blood samples collected in primary care for routine biochemistry testing and estimated glomerular filtration rate calculation. The median and range of κ:λ ratios found in each estimated glomerular filtration rate group used for chronic kidney disease classification were higher than previously described. This was the case for individuals with normal or essentially normal renal function with estimated glomerular filtration rates>90, (0.58-1.76) and estimated glomerular filtration rate of 60-90 mL/min/1.73 m(2), (0.71-1.93). Individuals with estimated glomerular filtration rate 15-30, (0.72-4.50) and estimated glomerular filtration rate <15 ml/min/1.73 m(2) (0.71-4.95) also had higher values when compared to the current renal reference range of 0.37-3.10. Elevation of free light chain-κ:λ ratios may occur in the absence of a reduced renal function shown by a normal estimated glomerular filtration rate and in the presence of reduced renal function by estimated glomerular filtration rate when comparing results with the established reference ranges. Explanations include choice of analytical systems or the presence of other concurrent non-plasma cell illness. © The Author(s) 2016.

  8. Multicenter Evaluation of Cystatin C Measurement after Assay Standardization.

    PubMed

    Bargnoux, Anne-Sophie; Piéroni, Laurence; Cristol, Jean-Paul; Kuster, Nils; Delanaye, Pierre; Carlier, Marie-Christine; Fellahi, Soraya; Boutten, Anne; Lombard, Christine; González-Antuña, Ana; Delatour, Vincent; Cavalier, Etienne

    2017-04-01

    Since 2010, a certified reference material ERM-DA471/IFCC has been available for cystatin C (CysC). This study aimed to assess the sources of uncertainty in results for clinical samples measured using standardized assays. This evaluation was performed in 2015 and involved 7 clinical laboratories located in France and Belgium. CysC was measured in a panel of 4 serum pools using 8 automated assays and a candidate isotope dilution mass spectrometry reference measurement procedure. Sources of uncertainty (imprecision and bias) were evaluated to calculate the relative expanded combined uncertainty for each CysC assay. Uncertainty was judged against the performance specifications derived from the biological variation model. Only Siemens reagents on the Siemens systems and, to a lesser extent, DiaSys reagents on the Cobas system, provided results that met the minimum performance criterion calculated according to the intraindividual and interindividual biological variations. Although the imprecision was acceptable for almost all assays, an increase in the bias with concentration was observed for Gentian reagents, and unacceptably high biases were observed for Abbott and Roche reagents on their own systems. This comprehensive picture of the market situation since the release of ERM-DA471/IFCC shows that bias remains the major component of the combined uncertainty because of possible problems associated with the implementation of traceability. Although some manufacturers have clearly improved their calibration protocols relative to ERM-DA471, most of them failed to meet the criteria for acceptable CysC measurements. © 2016 American Association for Clinical Chemistry.

  9. Direct calibration of a reference standard against the air kerma strength primary standard, at 192Ir HDR energy.

    PubMed

    Rajan, K N Govinda; Selvam, T Palani; Bhatt, B C; Vijayam, M; Patki, V S; Vinatha; Pendse, A M; Kannan, V

    2002-04-07

    The primary standard of low air kerma rate sources or beams, maintained at the Radiological Standards Laboratory (RSL) of the Bhabha Atomic Research Centre (BARC), is a 60 cm3 spherical graphite ionization chamber. A 192Ir HDR source was standardized at the hospital site in units of air kerma strength (AKS) using this primary standard. A 400 cm3 bakelite chamber, functioning as a reference standard at the RSL for a long period, at low air kerma rates (compared to external beam dose rates), was calibrated against the primary standard. It was seen that the primary standard and the reference standard, both being of low Z, showed roughly the same scatter response and yielded the same calibration factor for the 400 cm3 reference chamber, with or without room scatter. However, any likelihood of change in the reference chamber calibration factor would necessitate the re-transport of the primary standard to the hospital site for re-calibration. Frequent transport of the primary standard can affect the long-term stability of the primary standard, due to its movement or other extraneous causes. The calibration of the reference standard against the primary standard at the RSL, for an industrial type 192Ir source maintained at the laboratory, showed excellent agreement with the hospital calibration, making it possible to check the reference chamber calibration at RSL itself. Further calibration procedures have been developed to offer traceable calibration of the hospital well ionization chambers.

  10. Development and Evaluation of Reference Standards for Image-based Telemedicine Diagnosis and Clinical Research Studies in Ophthalmology

    PubMed Central

    Ryan, Michael C.; Ostmo, Susan; Jonas, Karyn; Berrocal, Audina; Drenser, Kimberly; Horowitz, Jason; Lee, Thomas C.; Simmons, Charles; Martinez-Castellanos, Maria-Ana; Chan, R.V. Paul; Chiang, Michael F.

    2014-01-01

    Information systems managing image-based data for telemedicine or clinical research applications require a reference standard representing the correct diagnosis. Accurate reference standards are difficult to establish because of imperfect agreement among physicians, and discrepancies between clinical vs. image-based diagnosis. This study is designed to describe the development and evaluation of reference standards for image-based diagnosis, which combine diagnostic impressions of multiple image readers with the actual clinical diagnoses. We show that agreement between image reading and clinical examinations was imperfect (689 [32%] discrepancies in 2148 image readings), as was inter-reader agreement (kappa 0.490-0.652). This was improved by establishing an image-based reference standard defined as the majority diagnosis given by three readers (13% discrepancies with image readers). It was further improved by establishing an overall reference standard that incorporated the clinical diagnosis (10% discrepancies with image readers). These principles of establishing reference standards may be applied to improve robustness of real-world systems supporting image-based diagnosis. PMID:25954463

  11. Selection of reference standard during method development using the analytical hierarchy process.

    PubMed

    Sun, Wan-yang; Tong, Ling; Li, Dong-xiang; Huang, Jing-yi; Zhou, Shui-ping; Sun, Henry; Bi, Kai-shun

    2015-03-25

    Reference standard is critical for ensuring reliable and accurate method performance. One important issue is how to select the ideal one from the alternatives. Unlike the optimization of parameters, the criteria of the reference standard are always immeasurable. The aim of this paper is to recommend a quantitative approach for the selection of reference standard during method development based on the analytical hierarchy process (AHP) as a decision-making tool. Six alternative single reference standards were assessed in quantitative analysis of six phenolic acids from Salvia Miltiorrhiza and its preparations by using ultra-performance liquid chromatography. The AHP model simultaneously considered six criteria related to reference standard characteristics and method performance, containing feasibility to obtain, abundance in samples, chemical stability, accuracy, precision and robustness. The priority of each alternative was calculated using standard AHP analysis method. The results showed that protocatechuic aldehyde is the ideal reference standard, and rosmarinic acid is about 79.8% ability as the second choice. The determination results successfully verified the evaluation ability of this model. The AHP allowed us comprehensive considering the benefits and risks of the alternatives. It was an effective and practical tool for optimization of reference standards during method development. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Pentobarbital quantitation using EMIT serum barbiturate assay reagents: application to monitoring of high-dose pentobarbital therapy.

    PubMed

    Pape, B E; Cary, P L; Clay, L C; Godolphin, W

    1983-01-01

    Pentobarbital serum concentrations associated with a high-dose therapeutic regimen were determined using EMIT immunoassay reagents. Replicate analyses of serum controls resulted in a within-assay coefficient of variation of 5.0% and a between-assay coefficient of variation of 10%. Regression analysis of 44 serum samples analyzed by this technique (y) and a reference procedure (x) were y = 0.98x + 3.6 (r = 0.98; x = ultraviolet spectroscopy) and y = 1.04x + 2.4 (r = 0.96; x = high-performance liquid chromatography). Clinical evaluation of the results indicates the immunoassay is sufficiently sensitive and selective for pentobarbital to allow accurate quantitation within the therapeutic range associated with high-dose therapy.

  13. Estimated Glomerular Filtration Rate; Laboratory Implementation and Current Global Status.

    PubMed

    Miller, W Greg; Jones, Graham R D

    2018-01-01

    In 2002, the Kidney Disease Outcomes Quality Initiative guidelines for identifying and treating CKD recommended that clinical laboratories report estimated glomerular filtration rate (eGFR) with every creatinine result to assist clinical practitioners to identify people with early-stage CKD. At that time, the original Modification of Diet in Renal Disease (MDRD) Study equation based on serum creatinine measurements was recommended for calculating eGFR. Because the MDRD Study equation was developed using a nonstandardized creatinine method, a Laboratory Working Group of the National Kidney Disease Education program was formed and implemented standardized calibration traceability for all creatinine methods from global manufacturers by approximately 2010. A modified MDRD Study equation for use with standardized creatinine was developed. The Chronic Kidney Disease Epidemiology Collaboration developed a new equation in 2009 that was more accurate than the MDRD Study equation at values above 60 mL/min/1.73 m 2 . As of 2017, reporting eGFR with creatinine is almost universal in many countries. A reference system for cystatin C became available in 2010, and manufacturers are in the process to standardize cystatin C assays. Equations for eGFR based on standardized cystatin C alone and with creatinine are now available from the Chronic Kidney Disease Epidemiology Collaboration and other groups. Copyright © 2017 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  14. Quantification of strontium in human serum by ICP-MS using alternate analyte-free matrix and its application to a pilot bioequivalence study of two strontium ranelate oral formulations in healthy Chinese subjects.

    PubMed

    Zhang, Dan; Wang, Xiaolin; Liu, Man; Zhang, Lina; Deng, Ming; Liu, Huichen

    2015-01-01

    A rapid, sensitive and accurate ICP-MS method using alternate analyte-free matrix for calibration standards preparation and a rapid direct dilution procedure for sample preparation was developed and validated for the quantification of exogenous strontium (Sr) from the drug in human serum. Serum was prepared by direct dilution (1:29, v/v) in an acidic solution consisting of nitric acid (0.1%) and germanium (Ge) added as internal standard (IS), to obtain simple and high-throughput preparation procedure with minimized matrix effect, and good repeatability. ICP-MS analysis was performed using collision cell technology (CCT) mode. Alternate matrix method by using distilled water as an alternate analyte-free matrix for the preparation of calibration standards (CS) was used to avoid the influence of endogenous Sr in serum on the quantification. The method was validated in terms of selectivity, carry-over, matrix effects, lower limit of quantification (LLOQ), linearity, precision and accuracy, and stability. Instrumental linearity was verified in the range of 1.00-500ng/mL, corresponding to a concentration range of 0.0300-15.0μg/mL in 50μL sample of serum matrix and alternate matrix. Intra- and inter-day precision as relative standard deviation (RSD) were less than 8.0% and accuracy as relative error (RE) was within ±3.0%. The method allowed a high sample throughput, and was sensitive and accurate enough for a pilot bioequivalence study in healthy male Chinese subjects following single oral administration of two strontium ranelate formulations containing 2g strontium ranelate. Copyright © 2014 Elsevier GmbH. All rights reserved.

  15. Uric acid and dehydration in children with gastroenteritis.

    PubMed

    Kuge, Rie; Morikawa, Yoshihiko; Hasegawa, Yukihiro

    2017-11-01

    Clinical assessment of dehydration in children with acute gastroenteritis (AGE) is crucial for treatment. The gold standard for assessment is acute weight loss. Dehydration severity, as determined by weight loss, significantly correlates with serum urea nitrogen (UN) in children with AGE. The disadvantage of using serum UN as a marker of dehydration severity, however, is that the level can be affected by nutrition. Serum uric acid (UA) theoretically could serve as an alternative in this regard, but there have been no reports on the direct relationship between serum UA and weight loss. The aim of this study was therefore to assess the relationship between serum UA and weight loss in patients with AGE. This was a prospective observational study of children 1-71 months of age admitted to Tokyo Metropolitan Children's Medical Center with AGE between 1 December 2010 and 31 March 2015. Patients with symptoms of AGE ≥ 8 days, chronic disease, or incomplete data were excluded from the study. Pre-post-rehydration weight change was used as an alternative, gold standard marker for the assessment of dehydration severity. The study participants consisted of 97 children. Serum UA correlated significantly with weight change, and increased significantly along with dehydration severity. Serum UA can be considered as an adjunct to the clinical assessment of dehydration in children with AGE. © 2017 Japan Pediatric Society.

  16. Anti-DNase I antibodies in systemic lupus erythematosus: diagnostic value and share in the enzyme inhibition.

    PubMed

    Trofimenko, A S; Gontar, I P; Zborovsky, A B; Paramonova, O V

    2016-04-01

    Diagnostic accuracy of anti-DNase I antibodies measurement in a differentiation between SLE and other autoimmune rheumatic diseases was evaluated. The share of anti-DNase I and actin in the DNase I activity decrease in SLE was established. Serum samples were obtained from 54 patients with verified SLE, 52 control patients with other autoimmune rheumatic diseases, and 44 healthy persons. Anti-DNase I concentrations were measured by ELISA. Free and actin inhibited DNase I activities were evaluated in the fresh serum samples. The appraisal of antibodies and actin effects on DNase I activity was made using multiple regression. Anti-DNase I antibodies were positive in 35 SLE and 8 control patients, without significant difference between the mean antibody concentrations. Sensitivity of this test was 64.81 %, and specificity-84.62 %. Mean free DNase I activity in SLE was somewhat lower than in the control group as a result of augmented frequency of extremely low enzyme activities. On the contrary, after the exclusion of the latter cases we have revealed elevated mean free DNase I activity in the other SLE patients comparing to the similar control subgroup. Unlike the controls, low serum DNase I activity in SLE arose not only from actin and antibody action, but also, in half of the cases, from unidentified factor, related to active SLE. The accuracy of the anti-DNase I antibodies measurement is approximate to the present reference standard of SLE diagnostics. We first demonstrated that neither antibodies nor actin caused DNase I activity decrease in SLE.

  17. The diagnostic accuracy of multi-frequency bioelectrical impedance analysis in diagnosing dehydration after stroke.

    PubMed

    Kafri, Mohannad W; Myint, Phyo Kway; Doherty, Danielle; Wilson, Alexander Hugh; Potter, John F; Hooper, Lee

    2013-07-10

    Non-invasive methods for detecting water-loss dehydration following acute stroke would be clinically useful. We evaluated the diagnostic accuracy of multi-frequency bioelectrical impedance analysis (MF-BIA) against reference standards serum osmolality and osmolarity. Patients admitted to an acute stroke unit were recruited. Blood samples for electrolytes and osmolality were taken within 20 minutes of MF-BIA. Total body water (TBW%), intracellular (ICW%) and extracellular water (ECW%), as percentages of total body weight, were calculated by MF-BIA equipment and from impedance measures using published equations for older people. These were compared to hydration status (based on serum osmolality and calculated osmolarity). The most promising Receiver Operating Characteristics curves were plotted. 27 stroke patients were recruited (mean age 71.3, SD10.7). Only a TBW% cut-off at 46% was consistent with current dehydration (serum osmolality >300 mOsm/kg) and TBW% at 47% impending dehydration (calculated osmolarity ≥295-300 mOsm/L) with sensitivity and specificity both >60%. Even here diagnostic accuracy of MF-BIA was poor, a third of those with dehydration were wrongly classified as hydrated and a third classified as dehydrated were well hydrated. Secondary analyses assessing diagnostic accuracy of TBW% for men and women separately, and using TBW as a percentage of lean body mass showed some promise, but did not provide diagnostically accurate measures across the population. MF-BIA appears ineffective at diagnosing water-loss dehydration after stroke and cannot be recommended as a test for dehydration, but separating assessment by sex, and using TBW as a percentage of lean body weight may warrant further investigation.

  18. PERIODIC LIMB MOVEMENTS AND RESTLESS LEGS SYNDROME IN CHILDREN WITH A HISTORY OF PREMATURITY

    PubMed Central

    Cielo, Christopher M.; DelRosso, Lourdes M.; Tapia, Ignacio E.; Biggs, Sarah N.; Nixon, Gillian M.; Meltzer, Lisa J.; Traylor, Joel; Kim, Ji Young; Marcus, Carole L.

    2017-01-01

    Introduction Little is known about which children are at increased risk for restless legs syndrome (RLS) and periodic limb movement disorder (PLMD). Polysomnographic data from the Caffeine for Apnea of Prematurity-Sleep (CAPS) study showed a high prevalence of elevated periodic limb movement index in a cohort of ex-preterm children, but the clinical importance of this finding, such as association with RLS, is unknown. We hypothesized that ex-preterm children would have a high prevalence of RLS and PLMD. Methods Ex-preterm children enrolled in CAPS, now aged 5-12 years, completed home polysomnography and standardized questionnaires. A diagnosis of RLS or PLMD was established by participants meeting the International Classification of Sleep Disorders, 3rd edition criteria based on questionnaires and polysomnograms. Clinically available serum ferritin levels were assessed. Results 167 participants underwent polysomnography and completed all questionnaires. The overall prevalence of RLS was 14/167 (8.4%). An additional 13 subjects (7.8%) were found to have PLMD. Of the 26 participants who had >5 periodic limb movements/hour, 7 (26.9%) had RLS and 13 (50%) had PLMD. Serum ferritin levels were <50 mcg/L (range 11 to 38.4) for all 8 participants referred for testing. Conclusions Children with a history of prematurity have a high prevalence of RLS, particularly those with elevated periodic limb movements. Iron deficiency likely contributes to RLS and PLMD symptoms in this population. Clinicians evaluating ex-preterm children with sleep disturbances should evaluate for RLS and PLMD. Further studies including serum ferritin evaluation are needed to confirm these findings. PMID:28215268

  19. Alternatives for the Bedside Schwartz Equation to Estimate Glomerular Filtration Rate in Children.

    PubMed

    Pottel, Hans; Dubourg, Laurence; Goffin, Karolien; Delanaye, Pierre

    2018-01-01

    The bedside Schwartz equation has long been and still is the recommended equation to estimate glomerular filtration rate (GFR) in children. However, this equation is probably best suited to estimate GFR in children with chronic kidney disease (reduced GFR) but is not optimal for children with GFR >75 mL/min/1.73 m 2 . Moreover, the Schwartz equation requires the height of the child, information that is usually not available in the clinical laboratory. This makes automatic reporting of estimated glomerular filtration rate (eGFR) along with serum creatinine impossible. As the majority of children (even children referred to nephrology clinics) have GFR >75 mL/min/1.73 m 2 , it might be interesting to evaluate possible alternatives to the bedside Schwartz equation. The pediatric form of the Full Age Spectrum (FAS) equation offers an alternative to Schwartz, allowing automatic reporting of eGFR since height is not necessary. However, when height is involved in the FAS equation, the equation is essentially equal to the Schwartz equation for children, but there are large differences for adolescents. Combining standardized biomarkers increases the prediction performance of eGFR equations for children, reaching P10 ≈ 45% and P30 ≈ 90%. There are currently good and simple alternatives to the bedside Schwartz equation, but the more complex equations combining serum creatinine, serum cystatin C, and height show the highest accuracy and precision. Copyright © 2017 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  20. Early pregnancy assessment with transvaginal ultrasound scanning.

    PubMed Central

    Daya, S; Woods, S; Ward, S; Lappalainen, R; Caco, C

    1991-01-01

    OBJECTIVE: To establish normal parameters in early pregnancy through transvaginal ultrasonography so that gestational age can be determined and to correlate the sonographic findings with serum human chorionic gonadotropin (hCG) levels calibrated against the first international reference preparation standard. SETTING: Infertility clinic. PATIENTS: Thirty-five women with normal intrauterine pregnancy. INTERVENTIONS: Serial measurement of the serum hCG level and the diameter of the gestational sac through transvaginal ultrasonography. MAIN RESULTS: The gestational sac could not be visualized when the hCG level was less than 1100 IU/L. The average growth rate of the sac was 0.9 mm/d. The threshold values for sac diameter, serum hCG level and gestational age below which the yolk sac was not visible were 3.7 mm, 1900 IU/L and 36 days respectively; the corresponding values above which the yolk sac was always visible were 6.7 mm, 5800 IU/L and 40 days. The threshold values below which cardiac activity was not visible were 8.3 mm, 9200 IU/L and 41 days respectively, and the corresponding values above which cardiac activity was always visible were 14.0 mm, 24,000 IU/L and 46 days. The mean gestational ages and the 95% confidence and prediction intervals were tabulated so that measurement of the gestational sac diameter could be used to estimate gestational age early in normal pregnancy. CONCLUSIONS: Transvaginal ultrasonography enables detection of an intrauterine sac and reliable estimation of gestational age on the basis of sac dimensions before an embryo can be seen. PMID:1993291

  1. The determination of ultrafiltrable calcium and magnesium in serum.

    PubMed

    Danielson, B G; Pallin, E; Sohtell, M

    1982-01-01

    Ultrafiltrate of human serum was investigated in order to evaluate the serum content of calcium and magnesium. The acid and base concentrations and pH of the serum was altered through titration with HCl- or NaOH-solutions. The Pco2 was varied in the titrated serum using different carbon dioxide tensions. This was performed when serum was filtered in a recycling system. It is shown that the analysis of calcium and magnesium have to be done under anaerobic conditions or at standardized pH and Pco2 situations, as the concentrations vary with both pH and Pco2. The concentration ratio between ultrafiltrate and serum for calcium and magnesium was found to be 0.56 and 0.74 respectively at pH=7.41 and Pco2=40 mmHg.

  2. Micro-scale method for liquid-chromatographic determination of chloramphenicol in serum.

    PubMed

    Petersdorf, S H; Raisys, V A; Opheim, K E

    1979-07-01

    We describe the use of "high-performance" liquid chromatography to measure chloramphenicol in as little as 25 microL of serum. Serum is treated to precipitate proteins with acetonitrile containing p-nitroacetanilide as an internal standard. Chloramphenicol is eluted with a mobile phase of methanol in pH 7.0 phosphate buffer (35/65 by vol). The drug is measured at 278 nm and simultaneously monitored at 254 nm; interfering substances are detected by examining the 278 nm/254 absorbance ratios. This method is sensitive to less than 0.5 mg/L and the standard curve is linear to at least 50 mg/L. Inter-day precision ranged between 3--6%. We encountered no interference from endogenous compounds or from other drugs we tested.

  3. 15 CFR 200.105 - Standard reference data.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ..., PROCEDURES, AND FEES § 200.105 Standard reference data. Data on the physical and chemical properties of the... application in research, development, engineering design, and commerce. The Office of Standard Reference Data... Physical and Chemical Reference Data, published jointly with the American Chemical Society and the American...

  4. 15 CFR 200.105 - Standard reference data.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ..., PROCEDURES, AND FEES § 200.105 Standard reference data. Data on the physical and chemical properties of the... application in research, development, engineering design, and commerce. The Office of Standard Reference Data... Physical and Chemical Reference Data, published jointly with the American Chemical Society and the American...

  5. 15 CFR 200.105 - Standard reference data.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ..., PROCEDURES, AND FEES § 200.105 Standard reference data. Data on the physical and chemical properties of the... application in research, development, engineering design, and commerce. The Office of Standard Reference Data... Physical and Chemical Reference Data, published jointly with the American Chemical Society and the American...

  6. 15 CFR 200.105 - Standard reference data.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ..., PROCEDURES, AND FEES § 200.105 Standard reference data. Data on the physical and chemical properties of the... application in research, development, engineering design, and commerce. The Office of Standard Reference Data... Physical and Chemical Reference Data, published jointly with the American Chemical Society and the American...

  7. Tocopherol in Elder Self-Neglect

    NASA Technical Reports Server (NTRS)

    Aung, K.; Burnett, J.; Dyer, C.; Smith, S. M.

    2009-01-01

    Although elder self-neglect is the most common form of elder mistreatment, its pathophysiology is not well understood. Alpha-tocopherol is a lipid soluble antioxidant required for the preservation of cell membranes. Since the association between tocopherol and cognitive impairment in older adults has been described, we explored the possibility of its role in elder self-neglect. OBJECTIVE: (1) To determine whether serum tocopherol levels are associated with elder self-neglect, and (2) to assess the association of serum tocopherol levels and cognitive function in elder self-neglect. METHODS: Serum tocopherol levels were measured in a cohort of 67 self-neglecting elders and 67 matched controls, recruited for the Consortium for Research in Elder Self-neglect of Texas. Pearson s correlation tests were performed to assess bivariate associations between serum tocopherol levels and cognitive function. RESULTS: Mean serum alpha-tocopherol levels were 10.8 +/- 4.7 ug/mL in self-neglect group and 13.0 +/- 4.9 ug/mL in control group (p = 0.006, unpaired student s t-test). None of the participants from either group had alpha-tocopherol level lower than the reference range. Mean serum gamma-tocopherol levels were 2.0 +/- 1.0 ug/mL in self-neglect group and 2.0 +/- 1.1 in control group (p=0.83). Proportion of the elders with gamma-tocopherol level lower than the reference range were 4.5% (3/66) in self-neglect group and 10.4% (7/67) in control group (p=0.32, Fisher s Exact Test). Among the self-neglecting elders, no association was found between serum alpha-tocopherol levels and the Mini-Mental State Examination (MMSE) or the Wolf-Klein Clock Drawing Test (CDT) scores (r =-0.42, p=0.75 for MMSE; r=0.08, p=0.54 for CDT). No association was found between serum gamma-tocopherol levels and the MMSE or the CDT (r=-0.12, p=0.35 for MMSE; r=0.05, p=0.68 for CDT). CONCLUSION: In our sample, neither alpha-tocopherol nor gamma-tocopherol appears to have a role in pathophysiology of elder self-neglect. Nevertheless, significantly lower serum alpha-tocopherol levels in the self neglect group merits further research.

  8. Short term serum pharmacokinetics of diammine silver fluoride after oral application.

    PubMed

    Vasquez, Elsa; Zegarra, Graciela; Chirinos, Edgar; Castillo, Jorge L; Taves, Donald R; Watson, Gene E; Dills, Russell; Mancl, Lloyd L; Milgrom, Peter

    2012-12-31

    There is growing interest in the use of diammine silver fluoride (DSF) as a topical agent to treat dentin hypersensitivity and dental caries as gauged by increasing published research from many parts of the world. While DSF has been available in various formulations for many years, most of its pharmacokinetic aspects within the therapeutic concentration range have never been fully characterized. This preliminary study determined the applied doses (3 teeth treated), maximum serum concentrations, and time to maximum serum concentration for fluoride and silver in 6 adults over 4 h. Fluoride was determined using the indirect diffusion method with a fluoride selective electrode, and silver was determined using inductively coupled plasma-mass spectrometry. The mean amount of DSF solution applied to the 3 teeth was 7.57 mg (6.04 μL). Over the 4 hour observation period, the mean maximum serum concentrations were 1.86 μmol/L for fluoride and 206 nmol/L for silver. These maximums were reached 3.0 h and 2.5 h for fluoride and silver, respectively. Fluoride exposure was below the U.S. Environmental Protection Agency (EPA) oral reference dose. Silver exposure exceeded the EPA oral reference dose for cumulative daily exposure over a lifetime, but for occasional use was well below concentrations associated with toxicity. This preliminary study suggests that serum concentrations of fluoride and silver after topical application of DSF should pose little toxicity risk when used in adults. NCT01664871.

  9. Short term serum pharmacokinetics of diammine silver fluoride after oral application

    PubMed Central

    2012-01-01

    Background There is growing interest in the use of diammine silver fluoride (DSF) as a topical agent to treat dentin hypersensitivity and dental caries as gauged by increasing published research from many parts of the world. While DSF has been available in various formulations for many years, most of its pharmacokinetic aspects within the therapeutic concentration range have never been fully characterized. Methods This preliminary study determined the applied doses (3 teeth treated), maximum serum concentrations, and time to maximum serum concentration for fluoride and silver in 6 adults over 4 h. Fluoride was determined using the indirect diffusion method with a fluoride selective electrode, and silver was determined using inductively coupled plasma-mass spectrometry. The mean amount of DSF solution applied to the 3 teeth was 7.57 mg (6.04 μL). Results Over the 4 hour observation period, the mean maximum serum concentrations were 1.86 μmol/L for fluoride and 206 nmol/L for silver. These maximums were reached 3.0 h and 2.5 h for fluoride and silver, respectively. Conclusions Fluoride exposure was below the U.S. Environmental Protection Agency (EPA) oral reference dose. Silver exposure exceeded the EPA oral reference dose for cumulative daily exposure over a lifetime, but for occasional use was well below concentrations associated with toxicity. This preliminary study suggests that serum concentrations of fluoride and silver after topical application of DSF should pose little toxicity risk when used in adults. Clinical trials registration NCT01664871. PMID:23272643

  10. The vitamin D status of the US population from 1988 to 2010 using standardized serum concentrations of 25-hydroxyvitamin D shows recent modest increases.

    PubMed

    Schleicher, Rosemary L; Sternberg, Maya R; Lacher, David A; Sempos, Christopher T; Looker, Anne C; Durazo-Arvizu, Ramon A; Yetley, Elizabeth A; Chaudhary-Webb, Madhulika; Maw, Khin L; Pfeiffer, Christine M; Johnson, Clifford L

    2016-08-01

    Temporal trends in the US population's vitamin D status have been uncertain because of nonstandardized serum 25-hydroxyvitamin D [25(OH)D] measurements. To accurately assess vitamin D status trends among those aged ≥12 y, we used data from the cross-sectional NHANESs. A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for measuring 25(OH)D (sum of 25-hydroxyvitamin D2 and 25-hydroxyvitamin D3), calibrated to standard reference materials, was used to predict LC-MS/MS-equivalent concentrations from radioimmunoassay data (1988-2006 surveys; n = 38,700) and to measure LC-MS/MS concentrations (2007-2010 surveys; n = 12,446). Weighted arithmetic means and the prevalence of 25(OH)D above or below cutoff concentrations were calculated to evaluate long-term trends. Overall, mean predicted 25(OH)D showed no time trend from 1988 to 2006, but during 2007-2010 the mean measured 25(OH)D was 5-6 nmol/L higher. Those groups who showed the largest 25(OH)D increases (7-11 nmol/L) were older, female, non-Hispanic white, and vitamin D supplement users. During 1988-2010, the proportions of persons with 25(OH)D <40 nmol/L were 14-18% (overall), 46-60% (non-Hispanic blacks), 21-28% (Mexican Americans), and 6-10% (non-Hispanic whites). An accurate method for measuring 25(OH)D showed stable mean concentrations in the US population (1988-2006) and recent modest increases (2007-2010). Although it is unclear to what extent supplement usage compared with different laboratory methods explain the increases in 25(OH)D, the use of higher vitamin D supplement dosages coincided with the increase. Marked race-ethnic differences in 25(OH)D concentrations were apparent. These data provide the first standardized information about temporal trends in the vitamin D status of the US population. © 2016 American Society for Nutrition.

  11. The Effect of Metformin and Standard Therapy Versus Standard Therapy Alone in Nondiabetic Patients with Insulin Resistance and Nonalcoholic Steatohepatitis (NASH): A Pilot Trial

    DTIC Science & Technology

    2009-01-01

    histology in nondiabetic patients with insulin resistance and NASH. Decrease in BMI through diet and exercise significantly improved HOMA - IR scores, serum...BMI through diet and exercise significantly improved HOMA - IR scores, serum aminotransferases and liver histology. 15. SUBJECT TERMS 16. SECURITY...insulin resistance (or HOMA - IR ) score was calculated using the formula: fasting insulin (mIU/ml) fasting glu- cose (mg/dl)/405 [Matthews et al. 1985

  12. Measures of body habitus are associated with lung function in adults with cystic fibrosis: A population-based study☆

    PubMed Central

    Forrester, Doug L.; Knox, Alan J.; Smyth, Alan R.; Fogarty, Andrew W.

    2013-01-01

    Background Body habitus differences may explain some of the variation in lung function between individuals with cystic fibrosis (CF). We tested the hypothesis that measures of lean muscle mass and obesity are independently associated with lung function in CF. Methods Cross-sectional study design using UK CF registry data from 2096 clinically stable adults. Results Serum creatinine and BMI were positively and independently associated with FEV1 and FVC. One standard deviation increment in serum creatinine was associated with an FEV1 increase of 171 ml (95% confidence intervals CI: + 116 to + 227 ml) in males and 90 ml (95% CI: + 46 to + 133 ml) in females. Compared to the reference group of 20–24.9 kg/m2, those with a BMI < 20 kg/m2 had lower FEV1 with values of − 642 ml (95%CI: − 784 to − 500 ml) for males and − 468 ml (95%CI: − 564 to − 372 ml) for females. Conclusions Prospective studies and controlled trials are required to ascertain if these associations have therapeutic potential in modifying disease progression. PMID:22958983

  13. Designing image segmentation studies: Statistical power, sample size and reference standard quality.

    PubMed

    Gibson, Eli; Hu, Yipeng; Huisman, Henkjan J; Barratt, Dean C

    2017-12-01

    Segmentation algorithms are typically evaluated by comparison to an accepted reference standard. The cost of generating accurate reference standards for medical image segmentation can be substantial. Since the study cost and the likelihood of detecting a clinically meaningful difference in accuracy both depend on the size and on the quality of the study reference standard, balancing these trade-offs supports the efficient use of research resources. In this work, we derive a statistical power calculation that enables researchers to estimate the appropriate sample size to detect clinically meaningful differences in segmentation accuracy (i.e. the proportion of voxels matching the reference standard) between two algorithms. Furthermore, we derive a formula to relate reference standard errors to their effect on the sample sizes of studies using lower-quality (but potentially more affordable and practically available) reference standards. The accuracy of the derived sample size formula was estimated through Monte Carlo simulation, demonstrating, with 95% confidence, a predicted statistical power within 4% of simulated values across a range of model parameters. This corresponds to sample size errors of less than 4 subjects and errors in the detectable accuracy difference less than 0.6%. The applicability of the formula to real-world data was assessed using bootstrap resampling simulations for pairs of algorithms from the PROMISE12 prostate MR segmentation challenge data set. The model predicted the simulated power for the majority of algorithm pairs within 4% for simulated experiments using a high-quality reference standard and within 6% for simulated experiments using a low-quality reference standard. A case study, also based on the PROMISE12 data, illustrates using the formulae to evaluate whether to use a lower-quality reference standard in a prostate segmentation study. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  14. Reference Standard Test and the Diagnostic Ability of Spectral Domain Optical Coherence Tomography in Glaucoma.

    PubMed

    Rao, Harsha L; Yadav, Ravi K; Addepalli, Uday K; Begum, Viquar U; Senthil, Sirisha; Choudhari, Nikhil S; Garudadri, Chandra S

    2015-08-01

    To evaluate the relationship between the reference standard used to diagnose glaucoma and the diagnostic ability of spectral domain optical coherence tomograph (SDOCT). In a cross-sectional study, 280 eyes of 175 consecutive subjects, referred to a tertiary eye care center for glaucoma evaluation, underwent optic disc photography, visual field (VF) examination, and SDOCT examination. The cohort was divided into glaucoma and control groups based on 3 reference standards for glaucoma diagnosis: first based on the optic disc classification (179 glaucoma and 101 control eyes), second on VF classification (glaucoma hemifield test outside normal limits and pattern SD with P-value of <5%, 130 glaucoma and 150 control eyes), and third on the presence of both glaucomatous optic disc and glaucomatous VF (125 glaucoma and 155 control eyes). Relationship between the reference standards and the diagnostic parameters of SDOCT were evaluated using areas under the receiver operating characteristic curve, sensitivity, and specificity. Areas under the receiver operating characteristic curve and sensitivities of most of the SDOCT parameters obtained with the 3 reference standards (ranging from 0.74 to 0.88 and 72% to 88%, respectively) were comparable (P>0.05). However, specificities of SDOCT parameters were significantly greater (P<0.05) with optic disc classification as reference standard (74% to 88%) compared with VF classification as reference standard (57% to 74%). Diagnostic parameters of SDOCT that was significantly affected by reference standard was the specificity, which was greater with optic disc classification as the reference standard. This has to be considered when comparing the diagnostic ability of SDOCT across studies.

  15. 34 CFR 73.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 34 Education 1 2011-07-01 2011-07-01 false Cross-reference to employee ethical conduct standards... of Education STANDARDS OF CONDUCT § 73.1 Cross-reference to employee ethical conduct standards and... branch-wide Standards of Ethical Conduct at 5 CFR part 2635 and to the Department of Education regulation...

  16. 34 CFR 73.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 34 Education 1 2010-07-01 2010-07-01 false Cross-reference to employee ethical conduct standards... of Education STANDARDS OF CONDUCT § 73.1 Cross-reference to employee ethical conduct standards and... branch-wide Standards of Ethical Conduct at 5 CFR part 2635 and to the Department of Education regulation...

  17. 34 CFR 73.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 34 Education 1 2014-07-01 2014-07-01 false Cross-reference to employee ethical conduct standards... of Education STANDARDS OF CONDUCT § 73.1 Cross-reference to employee ethical conduct standards and... branch-wide Standards of Ethical Conduct at 5 CFR part 2635 and to the Department of Education regulation...

  18. 34 CFR 73.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 34 Education 1 2013-07-01 2013-07-01 false Cross-reference to employee ethical conduct standards... of Education STANDARDS OF CONDUCT § 73.1 Cross-reference to employee ethical conduct standards and... branch-wide Standards of Ethical Conduct at 5 CFR part 2635 and to the Department of Education regulation...

  19. 34 CFR 73.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 34 Education 1 2012-07-01 2012-07-01 false Cross-reference to employee ethical conduct standards... of Education STANDARDS OF CONDUCT § 73.1 Cross-reference to employee ethical conduct standards and... branch-wide Standards of Ethical Conduct at 5 CFR part 2635 and to the Department of Education regulation...

  20. 7 CFR 1728.97 - Incorporation by reference of electric standards and specifications.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 11 2014-01-01 2014-01-01 false Incorporation by reference of electric standards and...) RURAL UTILITIES SERVICE, DEPARTMENT OF AGRICULTURE ELECTRIC STANDARDS AND SPECIFICATIONS FOR MATERIALS AND CONSTRUCTION § 1728.97 Incorporation by reference of electric standards and specifications. The...

  1. 7 CFR 1728.97 - Incorporation by reference of electric standards and specifications.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 11 2012-01-01 2012-01-01 false Incorporation by reference of electric standards and...) RURAL UTILITIES SERVICE, DEPARTMENT OF AGRICULTURE ELECTRIC STANDARDS AND SPECIFICATIONS FOR MATERIALS AND CONSTRUCTION § 1728.97 Incorporation by reference of electric standards and specifications. The...

  2. Serum prolactin in coeliac disease: a marker for disease activity

    PubMed Central

    Reifen, R.; Buskila, D.; Maislos, M.; Press, J.; Lerner, A.

    1997-01-01

    Accepted 21 April 1997
 Prolactin, a polypeptide hormone of anterior pituitary origin, has pronounced physiological effects on growth, reproduction, and osmoregulation. Increasing evidence indicates that prolactin also has an immunomodulatory influence on the immune system. The status of prolactin in patients with coeliac disease was investigated by obtaining serum samples from 48 patients with active and non-active coeliac disease. These were compared with samples from 20 children with familial Mediterranean fever and 65 normal controls. Serum prolactin in patients with active coeliac disease was significantly higher than in the other groups studied and reference values. Serum prolactin correlated well with the degree of mucosal atrophy and with the serum concentration of antiendomysial antibodies. Prolactin may play a part in immune modulation in the intestinal damage of coeliac disease and serve as a potential marker for disease activity.

 PMID:9301358

  3. Elevation of serum CA 125 and D-dimer levels associated with rupture of ovarian endometrioma.

    PubMed

    Uharcek, P; Mlyncek, M; Ravinger, J

    2007-01-01

    Patients with endometriosis rarely have a serum CA 125 concentration >100 IU/mL. A raised plasma level of D-dimer indicates active fibrinolysis, either secondary to clot formation or primarily activated. This condition is seldom diagnosed in patients with endometriosis. A 53-year-old woman was referred to our institution for acute abdominal pain. Laparoscopic surgery revealed a large ovarian cyst with rupture on the left side. Preoperative laboratory tests detected high serum CA 125 and D-dimer levels. Adnexectomy was performed, resulting in a sharp decrease in serum CA 125 and D-dimer concentration. We describe the clinical course of the patient. Rupture of a large ovarian endometrioma can lead to a high serum concentration of CA 125, a condition which, in addition to the detected pelvic mass, may mimic a malignant process. The increased D-dimer plasma level indicated that a ruptured endometriotic cyst can induce coagulation reactions.

  4. Effects of long-term oral administration of levothyroxine sodium on serum thyroid hormone concentrations, clinicopathologic variables, and echocardiographic measurements in healthy adult horses.

    PubMed

    Frank, Nicholas; Buchanan, Benjamin R; Elliott, Sarah B

    2008-01-01

    To determine the effects of long-term oral levothyroxine sodium (L-T(4)) administration on serum thyroid hormone concentrations, thyroid gland function, clinicopathologic variables, and echocardiographic examination measurements in adult euthyroid horses. 6 healthy adult mares. Horses received L-T(4) (48 mg/d) orally for 48 weeks. Every 4 weeks, physical examinations were performed; blood samples were collected for CBC, plasma biochemical analyses, and assessments of serum total triiodothyronine (tT(3)) and thyroxine (tT(4)) concentrations. Plasma creatine kinase MB activity and cardiac troponin I concentration were also measured. Echocardiographic examinations were performed before and at 16, 32, and 48 weeks during the treatment period. During the treatment period, mean body weight decreased significantly; heart rate varied significantly, but the pattern of variation was not consistent. Significant time effects were detected for certain clinicopathologic variables, but mean values remained within reference ranges. Cardiac troponin I was only detectable in 8 of 24 plasma samples (concentration range, 0.01 to 0.03 ng/mL). Serum creatine kinase MB activity did not change significantly over time. Compared with the pretreatment value, 5.4-, 4.0-, and 3.7-fold increases in mean serum tT(4) concentrations were detected at 16, 32, and 48 weeks, respectively. Some cardiac measurements changed significantly over time, but mean values remained within published reference ranges. Mean fractional shortening was lower than the pretreatment mean value at 16 and 32 weeks. In horses, long-term oral administration of 48 mg of L-T(4)/d significantly increased serum tT(4) concentrations and did not appear to adversely affect health.

  5. Use of the serum anti-Müllerian hormone assay as a surrogate for polycystic ovarian morphology: impact on diagnosis and phenotypic classification of polycystic ovary syndrome.

    PubMed

    Fraissinet, Alice; Robin, Geoffroy; Pigny, Pascal; Lefebvre, Tiphaine; Catteau-Jonard, Sophie; Dewailly, Didier

    2017-08-01

    Does the use of the serum anti-Müllerian hormone (AMH) assay to replace or complement ultrasound (U/S) affect the diagnosis or phenotypic distribution of polycystic ovary syndrome (PCOS)? Combining U/S and the serum AMH assay to define polycystic ovarian morphology (PCOM) diagnoses PCOS (according to the Rotterdam classification) in more patients than definitions using one or the other of these indicators exclusively. Since 2003, PCOM, as defined by U/S, is one of the three diagnostic criteria for PCOS. As it is closely correlated with follicle excess seen at U/S, an excessive serum AMH level could be used as a surrogate for PCOM. Single-center retrospective study from a database of prospectively collected clinical, laboratory and ultrasound data from patients referred for oligo-anovulation (OA) and/or hyperandrogenism (HA) between January 2009 and January 2016. The standard Rotterdam classification for PCOS was tested against two modified versions that defined PCOM by either excessive serum AMH level alone (AMH-only) or a combination (i.e. 'and/or') of the latter and U/S. The PCOS phenotypes were defined as A (full phenotype, OA+HA+PCOM), B (OA+HA), C (HA+PCOM) and D (OA+PCOM). PCOS was more frequently diagnosed when PCOM was defined as the combination 'positive U/S' and/or 'positive AMH' (n = 639) than by either only U/S-only (standard definition, n = 612) or by AMH-only (n = 601). With this combination, PCOM was recognized in 637 of the 639 cases that met the Rotterdam classification, and phenotype B practically disappeared. In this population, U/S and AMH markers were discordant for PCOM in 103 (16.1%) cases (9% U/S-only, 7.1% AMH-only, P = 0.159). The markers used had no other significant impact on the phenotypic distribution (except for phenotype B). However, the percentage of cases positive by U/S-only was significantly higher in phenotype D than in phenotype A (14.1% vs. 5.8%, P < 0.05). Furthermore, in the discordant cases, plasma LH levels were significantly higher in the AMH-only group than in the concordant cases, and fasting insulin serum levels tended to be higher in the U/S-only group. This is a retrospective study. A referral bias explains the relatively high proportion of patients with phenotype D (28%). PCOM was defined by in-house thresholds. The AMH assay used is no longer commercially available. Our results suggest that ideally both U/S data and serum AMH level should be integrated to define PCOM in the Rotterdam classification. In a cost-effectiveness approach, the choice of one or the other has little impact on the diagnosis and the phenotyping of PCOS. No external funding. The authors have no conflict of interest to declare. © The Author 2017. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com

  6. Lipid composition of leprosy-derived corynebacteria, a distinct group of corynebacteria, and of a reference Corynebacterium.

    PubMed

    Gailly, C; David, F; Sandra, P; Laneelle, M A; Cocito, C

    1993-01-01

    Leprosy-derived corynebacteria (LDC) are diphtheroid organisms isolated from leprosy patients and previously characterized by DNA and cell wall analysis. Three groups of LDC components of taxonomic value, glycolipids, and phospholipids and cell-wall-bound lipids were analyzed in comparison with those of a reference strain C. hoffmannii (CH). The main CH glycolipid, "cord factor" (trehalose dimycolate), was missing from LDC. Among phospholipids, phosphatidylinositol and phosphatidylglycerol had lowered proportions in LDC, as compared to CH, whereas phosphatidylethanolamine and cardiolipin were absent from both microorganisms. Bound lipids in acidic extracts of delipidated LDC yielded arabinose corynomycolate in lesser quantity with respect to CH. Alkaline hydrolysis of whole cells released fatty acids and mycolic acids, which were analyzed by gas chromatography/mass spectrometry. Reference CH, grown in the absence of serum, yielded C16:0 and C18:1 (major) and C18:0 (minor) fatty acids, as well as C32, C34, and C36 corynomycolic acids. All these components, particularly mycolates, had lowered proportions when this organism was grown in the presence of serum. Dominant LDC components were, in addition to C16:0, C18:0, and CI8:u fatty acids, cholesterol from serum. Very low concentrations of corynomycolic acids with a high degree of unsaturation were found in these organisms, suggesting a dependence of lipid metabolism on growth conditions. The presence in LDC of tuberculostearic acid (C19r:0), a mycobacterial component found in some pathogenic corynebacteria, was carefully explored: Traces of C19r:0 were found in LDC 19 grown in the presence of delipidated serum, but not in LDC 15 nor in C. hoffmannii. Present data, in conjunction with previous studies on DNA and mycolic acids, disclose basic differences in the composition of LDC and conventional corynebacteria.

  7. Reference values for serum leptin in healthy non-obese children and adolescents.

    PubMed

    Lausten-Thomsen, Ulrik; Christiansen, Michael; Louise Hedley, Paula; Esmann Fonvig, Cilius; Stjernholm, Theresa; Pedersen, Oluf; Hansen, Torben; Holm, Jens-Christian

    2016-11-01

    Adipokines are biologically active, low-molecular weight peptides, which play a major role in metabolic homeostasis in humans. Leptin has gained increasing attention in pediatrics as a biomarker for various metabolic pathologies. Yet, its usefulness is hampered by the relative lack of reference values from pediatric settings. Accordingly, this study aims to evaluate serum concentrations of leptin, soluble leptin receptor (sOB-R), and free leptin index (FLI) in healthy Danish schoolchildren aged 6-18 years and subsequently to establish reference intervals across sex and age groups. A total of 1193 healthy, non-obese Danish schoolchildren (730 girls, 463 boys) aged 6-18 years (median 11.9) were examined by trained medical staff. Serum leptin and sOB-R concentrations in venous fasting blood samples were quantitated by immunoassay. Percentile curves of leptin, sOB-R, and free leptin index were calculated using the General Additive Model for Location Scale and Shape (GAMLSS). Significant age and sex-dependent differences in circulating leptin levels were found. In boys, the median leptin concentration for all ages combined was 3.35 μg/L (95%-interval: 0.71-22.47) and in girls, it was 9.89 ng/L (95%-interval: 2.06-41.49). For SOB-R, no sex-specific difference was found, and the median sOB-R concentration was 8.24 μg/L (IQR: 3.58-23.74; range: < 1.56-744.15). We demonstrated an age-dependent correlation with both serum leptin concentration and free leptin index with a gradual and significant increase in girls throughout childhood and adolescence and a significantly higher leptin concentration and free leptin index bell-shaped peak in early adolescence in boys.

  8. Establishment of Biological Reference Intervals and Reference Curve for Urea by Exploratory Parametric and Non-Parametric Quantile Regression Models.

    PubMed

    Sarkar, Rajarshi

    2013-07-01

    The validity of the entire renal function tests as a diagnostic tool depends substantially on the Biological Reference Interval (BRI) of urea. Establishment of BRI of urea is difficult partly because exclusion criteria for selection of reference data are quite rigid and partly due to the compartmentalization considerations regarding age and sex of the reference individuals. Moreover, construction of Biological Reference Curve (BRC) of urea is imperative to highlight the partitioning requirements. This a priori study examines the data collected by measuring serum urea of 3202 age and sex matched individuals, aged between 1 and 80 years, by a kinetic UV Urease/GLDH method on a Roche Cobas 6000 auto-analyzer. Mann-Whitney U test of the reference data confirmed the partitioning requirement by both age and sex. Further statistical analysis revealed the incompatibility of the data for a proposed parametric model. Hence the data was non-parametrically analysed. BRI was found to be identical for both sexes till the 2(nd) decade, and the BRI for males increased progressively 6(th) decade onwards. Four non-parametric models were postulated for construction of BRC: Gaussian kernel, double kernel, local mean and local constant, of which the last one generated the best-fitting curves. Clinical decision making should become easier and diagnostic implications of renal function tests should become more meaningful if this BRI is followed and the BRC is used as a desktop tool in conjunction with similar data for serum creatinine.

  9. C-reactive protein reference percentiles among pre-adolescent children in Europe based on the IDEFICS study population.

    PubMed

    Schlenz, H; Intemann, T; Wolters, M; González-Gil, E M; Nappo, A; Fraterman, A; Veidebaum, T; Molnar, D; Tornaritis, M; Sioen, I; Mårild, S; Iacoviello, L; Ahrens, W

    2014-09-01

    C-reactive protein (CRP) is involved in a wide range of diseases. It is a powerful marker for inflammatory processes used for diagnostic and monitoring purposes. We aimed to establish reference values as data on the distribution of serum CRP levels in young European children are scarce. Reference values of high-sensitivity CRP concentrations were calculated for 9855 children aged 2.0-10.9 years, stratified by age and sex. The children were recruited during the population-based European IDEFICS study (Identification and prevention of Dietary- and lifestyle-induced health Effects in Children and infantS) with 18 745 participants recruited from 2007 to 2010. In 44.1% of the children, CRP values were below or equal the detection limit of 0.2 mg/l. Median CRP concentrations showed a slight negative age trend in boys and girls, whereas serum CRP values were slightly higher in girls than in boys across all age groups. Our population-based reference values of CRP may guide paediatric practice as elevated values may require further investigation or treatment. Therefore, the presented reference values represent a basis for clinical evaluation and for future research on risk assessment of diseases associated with increased CRP levels among children.

  10. Telemetry Standards, RCC Standard 106-17. Chapter 3. Frequency Division Multiplexing Telemetry Standards

    DTIC Science & Technology

    2017-07-01

    any of the listed reference frequencies may be used provided the requirements for compensation rate of change are satisfied. If the reference...for in present discriminator systems when the nominal response rating of the channels is employed and a reference frequency is recorded with the...Telemetry Standards, RCC Standard 106-17 Chapter 3, July 2017 3-i CHAPTER 3 Frequency Division Multiplexing Telemetry Standards Acronyms

  11. Correlation between the Severity and Type of Acne Lesions with Serum Zinc Levels in Patients with Acne Vulgaris

    PubMed Central

    Rostami Mogaddam, Majid; Safavi Ardabili, Nastaran; Soflaee, Maedeh

    2014-01-01

    Acne vulgaris is the most common cutaneous disorder affecting adolescents and young adults. Some studies have reported an association between serum zinc levels and acne vulgaris. We aimed to evaluate the serum zinc level in patients with acne vulgaris and compare it with healthy controls. One hundred patients with acne vulgaris and 100 healthy controls were referred to our clinic. Acne severity was classified according to Global Acne Grading System (GAGS). Atomic absorption spectrophotometry was used to measure serum zinc levels. Mean serum level of zinc in acne patients and controls was 81.31 ± 17.63 μg/dl and 82.63 ± 17.49 μg/dl, respectively. Although the mean serum zinc level was lower in acne group, it was not statistically significant (P = 0.598). There was a correlation between serum zinc levels with severity and type of acne lesions. The results of our study suggest that zinc levels may be related to the severity and type of acne lesions in patients with acne vulgaris. Relative decrease of serum zinc level in acne patients suggests a role for zinc in the pathogenesis of acne vulgaris. PMID:25157359

  12. Correlation between the severity and type of acne lesions with serum zinc levels in patients with acne vulgaris.

    PubMed

    Rostami Mogaddam, Majid; Safavi Ardabili, Nastaran; Maleki, Nasrollah; Soflaee, Maedeh

    2014-01-01

    Acne vulgaris is the most common cutaneous disorder affecting adolescents and young adults. Some studies have reported an association between serum zinc levels and acne vulgaris. We aimed to evaluate the serum zinc level in patients with acne vulgaris and compare it with healthy controls. One hundred patients with acne vulgaris and 100 healthy controls were referred to our clinic. Acne severity was classified according to Global Acne Grading System (GAGS). Atomic absorption spectrophotometry was used to measure serum zinc levels. Mean serum level of zinc in acne patients and controls was 81.31 ± 17.63 μg/dl and 82.63 ± 17.49 μg/dl, respectively. Although the mean serum zinc level was lower in acne group, it was not statistically significant (P = 0.598). There was a correlation between serum zinc levels with severity and type of acne lesions. The results of our study suggest that zinc levels may be related to the severity and type of acne lesions in patients with acne vulgaris. Relative decrease of serum zinc level in acne patients suggests a role for zinc in the pathogenesis of acne vulgaris.

  13. Bicentric evaluation of six anti-toxoplasma immunoglobulin G (IgG) automated immunoassays and comparison to the Toxo II IgG Western blot.

    PubMed

    Maudry, Arnaud; Chene, Gautier; Chatelain, Rémi; Patural, Hugues; Bellete, Bahrie; Tisseur, Bernard; Hafid, Jamal; Raberin, Hélène; Beretta, Sophie; Sung, Roger Tran Manh; Belot, Georges; Flori, Pierre

    2009-09-01

    A comparative study of the Toxoplasma IgG(I) and IgG(II) Access (Access I and II, respectively; Beckman Coulter Inc.), AxSYM Toxo IgG (AxSYM; Abbott Diagnostics), Vidas Toxo IgG (Vidas; bioMerieux, Marcy l'Etoile, France), Immulite Toxo IgG (Immulite; Siemens Healthcare Diagnostics Inc.), and Modular Toxo IgG (Modular; Roche Diagnostics, Basel, Switzerland) tests was done with 406 consecutive serum samples. The Toxo II IgG Western blot (LDBio, Lyon, France) was used as a reference technique in the case of intertechnique discordance. Of the 406 serum samples tested, the results for 35 were discordant by the different techniques. Using the 175 serum samples with positive results, we evaluated the standardization of the titrations obtained (in IU/ml); the medians (second quartiles) obtained were 9.1 IU/ml for the AxSYM test, 21 IU/ml for the Access I test, 25.7 IU/ml for the Access II test, 32 IU/ml for the Vidas test, 34.6 IU/ml for the Immulite test, and 248 IU/ml for the Modular test. For all the immunoassays tested, the following relative sensitivity and specificity values were found: 89.7 to 100% for the Access II test, 89.7 to 99.6% for the Immulite test, 90.2 to 99.6% for the AxSYM test, 91.4 to 99.6% for the Vidas test, 94.8 to 99.6% for the Access I test, and 98.3 to 98.7% for the Modular test. Among the 406 serum samples, we did not find any false-positive values by two different tests for the same serum sample. Except for the Modular test, which prioritized sensitivity, it appears that the positive cutoff values suggested by the pharmaceutical companies are very high (either for economical or for safety reasons). This led to imperfect sensitivity, a large number of unnecessary serological follow-ups of pregnant women, and difficulty in determining the serological status of immunosuppressed individuals.

  14. Residential distance to major roadways and semen quality, sperm DNA integrity, chromosomal disomy, and serum reproductive hormones among men attending a fertility clinic.

    PubMed

    Nassan, Feiby L; Chavarro, Jorge E; Mínguez-Alarcón, Lidia; Williams, Paige L; Tanrikut, Cigdem; Ford, Jennifer B; Dadd, Ramace; Perry, Melissa J; Hauser, Russ; Gaskins, Audrey J

    2018-06-01

    We examined associations of residential distance to major roadways, as a proxy for traffic-related air pollution exposures, with sperm characteristics and male reproductive hormones. The cohort included 797 men recruited from Massachusetts General Hospital Fertility Center between 2000 and 2015 to participate in fertility research studies. Men reported their residential addresses at enrollment and provided 1-6 semen samples and a blood sample during follow-up. We estimated the Euclidean distance to major roadways (e.g. interstates and highways: limited access highways, multi-lane highways (not limited access), other numbered routes, and major roads) using information from the Massachusetts Department of Geographic Information Systems. Semen parameters (1238 semen samples), sperm DNA integrity (389 semen samples), chromosomal disomy (101 semen samples), and serum reproductive hormones (405 serum samples) were assessed following standard procedures. Men in this cohort were primarily Caucasian (86%), not current smokers (92%), with a college or higher education (88%), and had an average age of 36 years and BMI of 27.7 kg/m 2 . The median (interquartile range) residential distance to a major roadway was 111 (37, 248) meters. Residential proximity to major roadways was not associated with semen parameters, sperm DNA integrity, chromosomal disomy, or serum reproductive hormone concentrations. The adjusted percent change (95% CI) in semen quality parameters associated with a 500 m increase in residential distance to a major roadway was -1.0% (-6.3, 4.5) for semen volume, 4.3% (-5.8, 15.7) for sperm concentration, 3.1% (-7.2, 14.5) for sperm count, 1.1% (-1.2, 3.4) for % total motile sperm, and 0.1% (-0.3, 0.5) for % morphologically normal sperm. Results were consistent when we modeled the semen parameters dichotomized according to WHO 2010 reference values. Residential distance to major roadways, as a proxy for traffic-related air pollution exposure, was not related to sperm characteristics or serum reproductive hormones among men attending a fertility clinic in Massachusetts. Copyright © 2018 Elsevier GmbH. All rights reserved.

  15. 49 CFR 1019.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 8 2011-10-01 2011-10-01 false Cross-reference to employee ethical conduct... Cross-reference to employee ethical conduct standards and financial disclosure regulations. Members and employees of the Surface Transportation Board also should refer to the executive branch Standards of Ethical...

  16. 49 CFR 1019.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 8 2010-10-01 2010-10-01 false Cross-reference to employee ethical conduct... Cross-reference to employee ethical conduct standards and financial disclosure regulations. Members and employees of the Surface Transportation Board also should refer to the executive branch Standards of Ethical...

  17. 49 CFR 1019.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 8 2014-10-01 2014-10-01 false Cross-reference to employee ethical conduct... Cross-reference to employee ethical conduct standards and financial disclosure regulations. Members and employees of the Surface Transportation Board also should refer to the executive branch Standards of Ethical...

  18. 49 CFR 1019.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 8 2013-10-01 2013-10-01 false Cross-reference to employee ethical conduct... Cross-reference to employee ethical conduct standards and financial disclosure regulations. Members and employees of the Surface Transportation Board also should refer to the executive branch Standards of Ethical...

  19. 49 CFR 1019.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 8 2012-10-01 2012-10-01 false Cross-reference to employee ethical conduct... Cross-reference to employee ethical conduct standards and financial disclosure regulations. Members and employees of the Surface Transportation Board also should refer to the executive branch Standards of Ethical...

  20. Studying the Relation of Postprandial Triglyceride with Coronary Artery Disease (CAD)

    PubMed Central

    Manochehri, Mohammad; Moghadam, Adel Johari

    2016-01-01

    Background: Coronary artery disease (CAD) is the most common cause of mortality worldwide and determination of contributing factors is essential. Aim: This study was conducted to study the relation of postprandial triglyceride as a risk of coronary artery disease in patients with proven CAD by angiography, referred to 502 Hospital of Army in 2015. Material and Methods: This observational study conducted as a case-control and contained 80 male participants referred to 502 Hospital of Army. Half of these participants had proven CAD by angiography test and the other ones were healthy as a control group. Fasting serum triglyceride was evaluated in all participants and postprandial TG was checked 4 hours after a standard meal. Obtained data were analyzed by SPSS ver. 13. Results: The results indicated that fasting TG and postprandial TG level were significantly higher in CAD patients (P-value=0.001). It was also shown evaluation of postprandial TG is more sensitive test than fasting TG in case of CAD patients. Conclusion: Our obtained results shown, evaluation of high level of postprandial TG is more reliable than fasting TG for patients whom suffer from CAD. PMID:27703285

  1. Detection of Human Immunodeficiency Virus Type 1 (HIV-1) RNA in Pools of Sera Negative for Antibodies to HIV-1 and HIV-2

    PubMed Central

    Morandi, Pierre-Alain; Schockmel, Gérard A.; Yerly, Sabine; Burgisser, Philippe; Erb, Peter; Matter, Lukas; Sitavanc, Radan; Perrin, Luc

    1998-01-01

    A total of 234 pools were prepared from 10,692 consecutive serum samples negative for antibodies to human immunodeficiency virus type 1 (HIV-1) and HIV-2 collected at five virological laboratories (average pool size, 45 serum samples). Pools were screened for the presence of HIV-1 RNA by a modified commercial assay (Amplicor HIV-1 Monitor test) which included an additional polyethylene glycol (PEG) precipitation step prior to purification of viral RNA (PEG Amplicor assay). The sensitivity of this assay for HIV-1 RNA detection in individual serum samples within pools matches that of standard commercial assays for individual serum samples, i.e., 500 HIV-1 RNA copies per ml. Five pools were identified as positive, and each one contained one antibody-negative, HIV-1 RNA-positive serum sample, corresponding to an average of 1 infected sample per 2,138 serum samples. Retrospective analysis revealed that the five HIV-1 RNA-positive specimens originated from individuals who had symptomatic primary HIV-1 infection at the time of sample collection and who were also positive for p24 antigenemia. We next assessed the possibility of performing the prepurification step by high-speed centrifugation (50,000 × g for 80 min) of 1.5-ml pools containing 25 μl of 60 individual serum samples, of which only 1 contained HIV-1 RNA (centrifugation Amplicor assay). The sensitivity of this assay also matches the sensitivities of standard commercial assays for HIV-1 RNA detection in individual serum samples. The results demonstrate that both assays with pooled sera can be applied to the screening of large numbers of serum samples in a time- and cost-efficient manner. PMID:9620372

  2. Optimized, Fast-Throughput UHPLC-DAD Based Method for Carotenoid Quantification in Spinach, Serum, Chylomicrons, and Feces.

    PubMed

    Eriksen, Jane N; Madsen, Pia L; Dragsted, Lars O; Arrigoni, Eva

    2017-02-01

    An improved UHPLC-DAD-based method was developed and validated for quantification of major carotenoids present in spinach, serum, chylomicrons, and feces. Separation was achieved with gradient elution within 12.5 min for six dietary carotenoids and the internal standard, echinenone. The proposed method provides, for all standard components, resolution > 1.1, linearity covering the target range (R > 0.99), LOQ < 0.035 mg/L, and intraday and interday RSDs < 2 and 10%, respectively. Suitability of the method was tested on biological matrices. Method precision (RSD%) for carotenoid quantification in serum, chylomicrons, and feces was below 10% for intra- and interday analysis, except for lycopene. Method accuracy was consistent with mean recoveries ranging from 78.8 to 96.9% and from 57.2 to 96.9% for all carotenoids, except for lycopene, in serum and feces, respectively. Additionally, an interlaboratory validation study on spinach at two institutions showed no significant differences in lutein or β-carotene content, when evaluated on four occasions.

  3. Concentrations of teicoplanin in serum and atrial appendages of patients undergoing cardiac surgery.

    PubMed Central

    Bergeron, M G; Saginur, R; Desaulniers, D; Trottier, S; Goldstein, W; Foucault, P; Lessard, C

    1990-01-01

    The concentrations of teicoplanin in sera and heart tissues of 49 patients undergoing coronary bypass were measured. Each patient received a 6- or 12-mg/kg dose of teicoplanin administered in a slow intravenous bolus injection over 3 to 5 min beginning at the time of induction of anesthesia. Mean +/- standard error of the mean concentrations in serum were, for the two doses, respectively, 58.1 +/- 1.7 and 123.3 +/- 7.4 micrograms/ml 5 min after administration and 22.2 +/- 0.7 and 56.5 +/- 2.8 micrograms/ml at the time of removal of atrial appendages. Mean +/- standard error of the mean concentrations in tissue were 70.6 +/- 1.7 and 139.8 +/- 2.2 micrograms/g, respectively, giving mean tissue/serum ratios of 3.7 +/- 0.3 and 2.8 +/- 0.2, respectively. Teicoplanin penetrates heart tissue readily and reaches levels in the serum far in excess of the MICs for most pathogens that have been found to cause infections following open heart surgery. PMID:2149493

  4. From plastic to gold: a unified classification scheme for reference standards in medical image processing

    NASA Astrophysics Data System (ADS)

    Lehmann, Thomas M.

    2002-05-01

    Reliable evaluation of medical image processing is of major importance for routine applications. Nonetheless, evaluation is often omitted or methodically defective when novel approaches or algorithms are introduced. Adopted from medical diagnosis, we define the following criteria to classify reference standards: 1. Reliance, if the generation or capturing of test images for evaluation follows an exactly determined and reproducible protocol. 2. Equivalence, if the image material or relationships considered within an algorithmic reference standard equal real-life data with respect to structure, noise, or other parameters of importance. 3. Independence, if any reference standard relies on a different procedure than that to be evaluated, or on other images or image modalities than that used routinely. This criterion bans the simultaneous use of one image for both, training and test phase. 4. Relevance, if the algorithm to be evaluated is self-reproducible. If random parameters or optimization strategies are applied, reliability of the algorithm must be shown before the reference standard is applied for evaluation. 5. Significance, if the number of reference standard images that are used for evaluation is sufficient large to enable statistically founded analysis. We demand that a true gold standard must satisfy the Criteria 1 to 3. Any standard only satisfying two criteria, i.e., Criterion 1 and Criterion 2 or Criterion 1 and Criterion 3, is referred to as silver standard. Other standards are termed to be from plastic. Before exhaustive evaluation based on gold or silver standards is performed, its relevance must be shown (Criterion 4) and sufficient tests must be carried out to found statistical analysis (Criterion 5). In this paper, examples are given for each class of reference standards.

  5. Serum and Plasma Cholinesterase Activity in the Cape Griffon Vulture (Gyps coprotheres).

    PubMed

    Naidoo, Vinny; Wolter, Kerri

    2016-04-28

    Vulture (Accipitridae) poisonings are a concern in South Africa, with hundreds of birds dying annually. Although some of these poisonings are accidental, there has been an increase in the number of intentional baiting of poached rhinoceros (Rhinocerotidae) and elephant (Elephantidae) carcasses to kill vultures that alert officials to poaching sites by circling overhead. The primary chemicals implicated are the organophosphorous and carbamate compounds. Although most poisoning events can be identified by dead vultures surrounding the scavenged carcass, weak birds are occasionally found and brought to rehabilitation centers for treatment. The treating veterinarian needs to make an informed decision on the cause of illness or poisoning prior to treatment. We established the reference interval for serum and plasma cholinesterase activity in the Cape Griffon Vulture ( Gyps coprotheres ) as 591.58-1,528.26 U/L, providing a clinical assay for determining potential exposure to cholinesterase-depressing pesticides. Both manual and automated samplers were used with the butyrylthiocholine method. Species reference intervals for both serum and plasma cholinesterase showed good correlation and manual and automated measurements yielded similar results.

  6. Evaluation of serum lysyl oxidase as a blood test for colorectal cancer.

    PubMed

    Ward, S T; Weston, C J; Hepburn, E; Damery, S; Hejmadi, R K; Morton, D G; Middleton, G; Ismail, T; Adams, D H

    2014-06-01

    Lysyl oxidase (LOX) expression is elevated in colorectal cancer (CRC) tissue and associated with disease progression. A blood test may form a more acceptable diagnostic test for CRC although LOX has not previously been measured in the serum. We therefore sought to determine the clinical usefulness of a serum LOX test for CRC in a symptomatic population. Adult patients referred to a hospital colorectal clinic with bowel symptoms completed a questionnaire and provided a blood sample for serum LOX measurement. Associations between presenting symptoms, serum LOX concentrations and outcomes of investigations were tested by univariate and multivariate analyses to determine if serum LOX was clinically useful in the prediction of CRC. LOX expression in CRC and adjacent colon biopsies was evaluated by ELISA and immunohistochemistry. Thirty-one cases of colorectal cancer and 16 high-risk polyps were identified from a total of 962 participants. There was no association between serum LOX concentration and the presence of CRC, high-risk polyps or cancers at any site. LOX expression was significantly increased in CRC tissue compared to adjacent colon. Despite overexpression of LOX in CRC tissue, elevated serum levels could not be demonstrated. Serum LOX measurement is therefore not a clinically useful test for CRC. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. A new application of micellar liquid chromatography in the determination of free ampicillin concentration in the drug-human serum albumin standard solution in comparison with the adsorption method.

    PubMed

    Stępnik, Katarzyna E; Malinowska, Irena; Maciejewska, Małgorzata

    2016-06-01

    The determination of free drug concentration is a very important issue in the field of pharmacology because only the unbound drug fraction can achieve a pharmacological effect. Due to the ability to solubilize many different compounds in micellar aggregates, micellar liquid chromatography (MLC) can be used for direct determination of free drug concentration. Proteins are not retained on the stationary phase probably due to the formation of protein - surfactant complexes which are excluded from the pores of stationary phase. The micellar method is simple and fast. It does not require any pre-preparation of the tested samples for analysis. The main aim of this paper is to demonstrate a completely new applicability of the analytical use of MLC concerning the determination of free drug concentration in the standard solution of human serum albumin. The well-known adsorption method using RP-HPLC and the spectrophotometric technique was applied as the reference method. The results show that the free drug concentration value obtained in the MLC system (based on the RP-8 stationary phase and CTAB) is similar to that obtained by the adsorption method: both RP-HPLC (95.83μgmL(-1), 79.86% of free form) and spectrophotometry (95.71μgmL(-1), 79.76%). In the MLC the free drug concentration was 93.98μgmL(-1) (78.3%). This indicates that the obtained results are within the analytical range of % of free ampicillin fraction and the MLC with direct sample injection can be treated like a promising method for the determination of free drug concentration. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Using Hashimoto thyroiditis as gold standard to determine the upper limit value of thyroid stimulating hormone in a Chinese cohort.

    PubMed

    Li, Yu; Chen, Dong-Ning; Cui, Jing; Xin, Zhong; Yang, Guang-Ran; Niu, Ming-Jia; Yang, Jin-Kui

    2016-11-06

    Subclinical hypothyroidism, commonly caused by Hashimoto thyroiditis (HT), is a risk factor for cardiovascular diseases. This disorder is defined as merely having elevated serum thyroid stimulating hormone (TSH) levels. However, the upper limit of reference range for TSH is debated recently. This study was to determine the cutoff value for the upper normal limit of TSH in a cohort using the prevalence of Hashimoto thyroiditis as "gold" calibration standard. The research population was medical staff of 2856 individuals who took part in health examination annually. Serum free triiodothyronine (FT3), free thyroxine (FT4), TSH, thyroid peroxidase antibody (TPAb), thyroglobulin antibody (TGAb) and other biochemistry parameters were tested. Meanwhile, thyroid ultrasound examination was performed. The diagnosis of HT was based on presence of thyroid antibodies (TPAb and TGAb) and abnormalities of thyroid ultrasound examination. We used two different methods to estimate the cutoff point of TSH based on the prevalence of HT. Joinpoint regression showed the prevalence of HT increased significantly at the ninth decile of TSH value corresponding to 2.9 mU/L. ROC curve showed a TSH cutoff value of 2.6 mU/L with the maximized sensitivity and specificity in identifying HT. Using the newly defined cutoff value of TSH can detect patients with hyperlipidemia more efficiently, which may indicate our approach to define the upper limit of TSH can make more sense from the clinical point of view. A significant increase in the prevalence of HT occurred among individuals with a TSH of 2.6-2.9 mU/L made it possible to determine the cutoff value of normal upper limit of TSH.

  9. Equine alpha-fetoprotein levels in Lipizzaner mares with normal pregnancies and with pregnancy loss.

    PubMed

    Vincze, Boglárka; Gáspárdy, András; Kulcsár, Margit; Baska, Ferenc; Bálint, Ádám; Hegedűs, György Tamás; Szenci, Ottó

    2015-12-01

    Alpha-fetoprotein has proved to be a good indicator of fetal well-being in human medicine for decades. Although this molecule is present in most of the mammalian species including horses, reference values in healthy and high-risk pregnant mares have not yet been published. The aim of the present study was to determine whether equine alpha-fetoprotein (eqAFP) is a good indicator of complicated pregnancies in Lipizzaner mares. A total of 111 serum samples from 30 mares have been analyzed for eqAFP levels throughout gestation (Days 60-325). After the pregnancy was confirmed, 23 mares had normal pregnancies with viable foals, six had late embryonic loss, and one of the mares aborted in the ninth gestational month. Equine alpha-fetoprotein concentrations significantly differed in the normal group (72.93 ± 49.25 pg/mL; mean ± standard deviation) and in the complicated pregnancy loss group (152 ± 36.48 pg/mL; mean ± standard deviation). The mares' age, gestational age, and the conception rate significantly affected the alpha-fetoprotein concentrations in the normal group. Furthermore, notable individual differences occurred in eqAFP concentrations between mares. Equine alpha-fetoprotein seems to be an important indicator of fetal well-being in horses, but there are still some unanswered questions (levels in foals of different age, ponies, and draft horses) regarding this serum protein. Large-scale studies are needed to assess the specificity, sensitivity, and reliability of this test as a possible future diagnostic tool for fetal well-being in horses. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. 28 CFR 45.1 - Cross-reference to ethical standards and financial disclosure regulations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 28 Judicial Administration 2 2011-07-01 2011-07-01 false Cross-reference to ethical standards and...) EMPLOYEE RESPONSIBILITIES § 45.1 Cross-reference to ethical standards and financial disclosure regulations. Employees of the Department of Justice are subject to the executive branch-wide Standards of Ethical Conduct...

  11. 10 CFR 1010.102 - Cross-references to employee ethical conduct standards, financial disclosure regulations, and...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 4 2011-01-01 2011-01-01 false Cross-references to employee ethical conduct standards... Cross-references to employee ethical conduct standards, financial disclosure regulations, and other conduct rules. Employees of DOE are subject to the Standards of Ethical Conduct for Employees of the...

  12. 28 CFR 45.1 - Cross-reference to ethical standards and financial disclosure regulations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Cross-reference to ethical standards and...) EMPLOYEE RESPONSIBILITIES § 45.1 Cross-reference to ethical standards and financial disclosure regulations. Employees of the Department of Justice are subject to the executive branch-wide Standards of Ethical Conduct...

  13. 10 CFR 1010.102 - Cross-references to employee ethical conduct standards, financial disclosure regulations, and...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 4 2013-01-01 2013-01-01 false Cross-references to employee ethical conduct standards... Cross-references to employee ethical conduct standards, financial disclosure regulations, and other conduct rules. Employees of DOE are subject to the Standards of Ethical Conduct for Employees of the...

  14. 10 CFR 1010.102 - Cross-references to employee ethical conduct standards, financial disclosure regulations, and...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 4 2012-01-01 2012-01-01 false Cross-references to employee ethical conduct standards... Cross-references to employee ethical conduct standards, financial disclosure regulations, and other conduct rules. Employees of DOE are subject to the Standards of Ethical Conduct for Employees of the...

  15. 28 CFR 45.1 - Cross-reference to ethical standards and financial disclosure regulations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 28 Judicial Administration 2 2013-07-01 2013-07-01 false Cross-reference to ethical standards and...) EMPLOYEE RESPONSIBILITIES § 45.1 Cross-reference to ethical standards and financial disclosure regulations. Employees of the Department of Justice are subject to the executive branch-wide Standards of Ethical Conduct...

  16. 10 CFR 1010.102 - Cross-references to employee ethical conduct standards, financial disclosure regulations, and...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 4 2014-01-01 2014-01-01 false Cross-references to employee ethical conduct standards... Cross-references to employee ethical conduct standards, financial disclosure regulations, and other conduct rules. Employees of DOE are subject to the Standards of Ethical Conduct for Employees of the...

  17. 28 CFR 45.1 - Cross-reference to ethical standards and financial disclosure regulations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 28 Judicial Administration 2 2012-07-01 2012-07-01 false Cross-reference to ethical standards and...) EMPLOYEE RESPONSIBILITIES § 45.1 Cross-reference to ethical standards and financial disclosure regulations. Employees of the Department of Justice are subject to the executive branch-wide Standards of Ethical Conduct...

  18. 28 CFR 45.1 - Cross-reference to ethical standards and financial disclosure regulations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 28 Judicial Administration 2 2014-07-01 2014-07-01 false Cross-reference to ethical standards and...) EMPLOYEE RESPONSIBILITIES § 45.1 Cross-reference to ethical standards and financial disclosure regulations. Employees of the Department of Justice are subject to the executive branch-wide Standards of Ethical Conduct...

  19. A comparison of three infant skinfold reference standards: Tanner-Whitehouse, Cambridge Infant Growth Study, and WHO Child Growth Standards.

    PubMed

    Miller, Elizabeth M

    2015-10-01

    As researchers increasingly focus on early infancy as a critical period of development, there is a greater need for methodological tools that can address all aspects of infant growth. Infant skinfold measures, in particular, are measurements in need of reliable reference standards that encompass all ages of infants and provide an accurate assessment of the relative fatness of a population. This report evaluates three published reference standards for infant skinfold measurements: Tanner-Whitehouse, Cambridge Infant Growth Study, and the World Health Organization (WHO) Child Growth Standards. To assess these standards, triceps skinfolds from a population of rural Kenyan infants (n = 250) and triceps skinfolds and subscapular skinfolds from infants in the National Health and Nutrition Examination Survey 1999-2002 (NHANES; n = 1197) were calculated as z-scores from the lambda-mu-sigma curves provided by each reference population. The Tanner-Whitehouse standards represented both the Kenyan and US populations as lean, while the Cambridge standards represented both populations as overfat. The distribution of z-scores based on the WHO standards fell in the middle, but excluded infants from both populations who were below the age of 3 months. Based on these results, the WHO reference standard is the best skinfold reference standard for infants over the age of 3 months. For populations with infants of all ages, the Tanner-Whitehouse standards are recommended, despite representing both study populations as underfat. Ideally, the WHO will extend their reference standard to include infants between the ages of 0 and 3 months. © 2014 John Wiley & Sons Ltd.

  20. Serum Dried Samples to Detect Dengue Antibodies: A Field Study.

    PubMed

    Maldonado-Rodríguez, Angelica; Rojas-Montes, Othon; Vazquez-Rosales, Guillermo; Chavez-Negrete, Adolfo; Rojas-Uribe, Magdalena; Posadas-Mondragon, Araceli; Aguilar-Faisal, Leopoldo; Cevallos, Ana Maria; Xoconostle-Cazares, Beatriz; Lira, Rosalia

    2017-01-01

    Dried blood and serum samples are useful resources for detecting antiviral antibodies. The conditions for elution of the sample need to be optimized for each disease. Dengue is a widespread disease in Mexico which requires continuous surveillance. In this study, we standardized and validated a protocol for the specific detection of dengue antibodies from dried serum spots (DSSs). Paired serum and DSS samples from 66 suspected cases of dengue were collected in a clinic in Veracruz, Mexico. Samples were sent to our laboratory, where the conditions for optimal elution of DSSs were established. The presence of anti-dengue antibodies was determined in the paired samples. DSS elution conditions were standardized as follows: 1 h at 4°C in 200  µ l of DNase-, RNase-, and protease-free PBS (1x). The optimal volume of DSS eluate to be used in the IgG assay was 40  µ l. Sensitivity of 94%, specificity of 93.3%, and kappa concordance of 0.87 were obtained when comparing the antidengue reactivity between DSSs and serum samples. DSS samples are useful for detecting anti-dengue IgG antibodies in the field.