Sample records for standard sensitivity specificity

  1. Head-To-Head Comparison Between High- and Standard-b-Value DWI for Detecting Prostate Cancer: A Systematic Review and Meta-Analysis.

    PubMed

    Woo, Sungmin; Suh, Chong Hyun; Kim, Sang Youn; Cho, Jeong Yeon; Kim, Seung Hyup

    2018-01-01

    The purpose of this study was to perform a head-to-head comparison between high-b-value (> 1000 s/mm 2 ) and standard-b-value (800-1000 s/mm 2 ) DWI regarding diagnostic performance in the detection of prostate cancer. The MEDLINE and EMBASE databases were searched up to April 1, 2017. The analysis included diagnostic accuracy studies in which high- and standard-b-value DWI were used for prostate cancer detection with histopathologic examination as the reference standard. Methodologic quality was assessed with the revised Quality Assessment of Diagnostic Accuracy Studies tool. Sensitivity and specificity of all studies were calculated and were pooled and plotted in a hierarchic summary ROC plot. Meta-regression and multiple-subgroup analyses were performed to compare the diagnostic performances of high- and standard-b-value DWI. Eleven studies (789 patients) were included. High-b-value DWI had greater pooled sensitivity (0.80 [95% CI, 0.70-0.87]) (p = 0.03) and specificity (0.92 [95% CI, 0.87-0.95]) (p = 0.01) than standard-b-value DWI (sensitivity, 0.78 [95% CI, 0.66-0.86]); specificity, 0.87 [95% CI, 0.77-0.93] (p < 0.01). Multiple-subgroup analyses showed that specificity was consistently higher for high- than for standard-b-value DWI (p ≤ 0.05). Sensitivity was significantly higher for high- than for standard-b-value DWI only in the following subgroups: peripheral zone only, transition zone only, multiparametric protocol (DWI and T2-weighted imaging), visual assessment of DW images, and per-lesion analysis (p ≤ 0.04). In a head-to-head comparison, high-b-value DWI had significantly better sensitivity and specificity for detection of prostate cancer than did standard-b-value DWI. Multiple-subgroup analyses showed that specificity was consistently superior for high-b-value DWI.

  2. Research Diagnostic Criteria for Temporomandibular Disorders: Validity of Axis I Diagnoses

    PubMed Central

    Truelove, Edmond; Pan, Wei; Look, John O.; Mancl, Lloyd A.; Ohrbach, Richard K.; Velly, Ana; Huggins, Kimberly; Lenton, Patricia; Schiffman, Eric L.

    2011-01-01

    AIMS To estimate the criterion validity of the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) Axis I TMD diagnoses. METHODS A combined total of 614 TMD community and clinic cases and 91 controls were examined at 3 study sites. RDC/TMD Axis I diagnoses were algorithmically derived from an examination performed by calibrated dental hygienists. Reference standards (Gold Standards) were established by means of consensus diagnoses rendered by 2 TMD experts using all available clinical data, including imaging studies. Validity of the RDC/TMD Axis I TMD diagnoses was estimated relative to reference-standard diagnoses (gold standard diagnoses). Target sensitivity and specificity were set a priori at ≥ 0.70 and ≥ 0.95, respectively. RESULTS Target sensitivity and specificity were not observed for any of the 8 RDC/TMD diagnoses. The highest validity was achieved for Group Ia myofascial pain (sensitivity 0.65, specificity 0.92) and Group Ib myofascial pain with limited opening (sensitivity 0.79, specificity 0.92). Target sensitivity and specificity were observed only when both Group I diagnoses were combined (0.87 and 0.98, respectively). For Group II (disc displacements) and Group III (arthralgia, arthritis, arthrosis) diagnoses, all estimates for sensitivity were below target (0.03 to 0.53), and specificity ranged from below to on target (0.86 to 0.99). CONCLUSION The RDC/TMD Axis I TMD diagnoses did not reach the targets set at sensitivity of ≥ 0.70 and specificity of ≥ 0.95. Target validity was obtained only for myofascial pain without differentiation between normal and limited opening. Revision of the current Axis I TMD diagnostic algorithms is warranted to improve their validity. PMID:20213030

  3. Imperfect Gold Standards for Kidney Injury Biomarker Evaluation

    PubMed Central

    Betensky, Rebecca A.; Emerson, Sarah C.; Bonventre, Joseph V.

    2012-01-01

    Clinicians have used serum creatinine in diagnostic testing for acute kidney injury for decades, despite its imperfect sensitivity and specificity. Novel tubular injury biomarkers may revolutionize the diagnosis of acute kidney injury; however, even if a novel tubular injury biomarker is 100% sensitive and 100% specific, it may appear inaccurate when using serum creatinine as the gold standard. Acute kidney injury, as defined by serum creatinine, may not reflect tubular injury, and the absence of changes in serum creatinine does not assure the absence of tubular injury. In general, the apparent diagnostic performance of a biomarker depends not only on its ability to detect injury, but also on disease prevalence and the sensitivity and specificity of the imperfect gold standard. Assuming that, at a certain cutoff value, serum creatinine is 80% sensitive and 90% specific and disease prevalence is 10%, a new perfect biomarker with a true 100% sensitivity may seem to have only 47% sensitivity compared with serum creatinine as the gold standard. Minimizing misclassification by using more strict criteria to diagnose acute kidney injury will reduce the error when evaluating the performance of a biomarker under investigation. Apparent diagnostic errors using a new biomarker may be a reflection of errors in the imperfect gold standard itself, rather than poor performance of the biomarker. The results of this study suggest that small changes in serum creatinine alone should not be used to define acute kidney injury in biomarker or interventional studies. PMID:22021710

  4. Fat-suppressed three-dimensional spoiled gradient-echo MR imaging of hyaline cartilage defects in the knee: comparison with standard MR imaging and arthroscopy.

    PubMed

    Disler, D G; McCauley, T R; Kelman, C G; Fuchs, M D; Ratner, L M; Wirth, C R; Hospodar, P P

    1996-07-01

    The sensitivity of fat-suppressed three-dimensional spoiled gradient-echo (SPGR) images was compared with that of standard MR images for detecting hyaline cartilage defects of the knee, using arthroscopy as the standard of reference. We assessed 114 consecutive patients for hyaline cartilage defects of the knee with both standard MR imaging sequences and a sagittal fat-suppressed three-dimensional SPGR sequence. Of these patients, 48 with meniscal or ligament injury, or persistent symptoms, underwent subsequent arthroscopy. The standard MR images and SPGR images of these 48 patients were then retrospectively analyzed for articular defects in a blinded fashion by two independent observers. Sensitivity, specificity, and intraobserver and interobserver agreement were determined for the different imaging techniques. One fourth of the patients who went on to arthroscopy were shown to have isolated hyaline cartilage lesions that were clinically confused with meniscal tears and that were missed on the standard MR images. When looking at all surfaces combined for each reader, the SPGR imaging sequence had a significantly higher sensitivity than the standard MR imaging sequences for detecting hyaline cartilage defects (75-85% versus 29-38%, p < .001 for each comparison). When looking at individual surfaces for each reader, significant differences in sensitivity were shown for each surface except the trochlear and lateral tibial surfaces. We found no difference in specificity (97% versus 97%, p > .99). We also found that combined evaluation of standard MR and SPGR images gave no added diagnostic advantage (sensitivity, 86%; specificity, 97%; p > .42). Except for the lateral tibial surface, the study achieved excellent reproducibility among readings and between readers. Fat-suppressed three-dimensional SPGR imaging is more sensitive than standard MR imaging for the detection of hyaline cartilage defects of the knee.

  5. Partial verification bias and incorporation bias affected accuracy estimates of diagnostic studies for biomarkers that were part of an existing composite gold standard.

    PubMed

    Karch, Annika; Koch, Armin; Zapf, Antonia; Zerr, Inga; Karch, André

    2016-10-01

    To investigate how choice of gold standard biases estimates of sensitivity and specificity in studies reassessing the diagnostic accuracy of biomarkers that are already part of a lifetime composite gold standard (CGS). We performed a simulation study based on the real-life example of the biomarker "protein 14-3-3" used for diagnosing Creutzfeldt-Jakob disease. Three different types of gold standard were compared: perfect gold standard "autopsy" (available in a small fraction only; prone to partial verification bias), lifetime CGS (including the biomarker under investigation; prone to incorporation bias), and "best available" gold standard (autopsy if available, otherwise CGS). Sensitivity was unbiased when comparing 14-3-3 with autopsy but overestimated when using CGS or "best available" gold standard. Specificity of 14-3-3 was underestimated in scenarios comparing 14-3-3 with autopsy (up to 24%). In contrast, overestimation (up to 20%) was observed for specificity compared with CGS; this could be reduced to 0-10% when using the "best available" gold standard. Choice of gold standard affects considerably estimates of diagnostic accuracy. Using the "best available" gold standard (autopsy where available, otherwise CGS) leads to valid estimates of specificity, whereas sensitivity is estimated best when tested against autopsy alone. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Sensitivity and specificity of the lymphocyte transformation test in drug reaction with eosinophilia and systemic symptoms causality assessment.

    PubMed

    Cabañas, R; Calderón, O; Ramírez, E; Fiandor, A; Caballero, T; Heredia, R; Herranz, P; Madero, R; Quirce, S; Bellón, T

    2018-03-01

    Drug reaction with eosinophilia and systemic symptoms (DRESS) is a severe delayed hypersensitivity reaction. The determination of drug causality is complex. The lymphocyte transformation test (LTT) has been reported positive in more than 50% of DRESS cases. Nevertheless, the sensitivity and specificity of LTT specifically in DRESS have not yet been established. Rechallenge with the culprit drug is contraindicated and cannot be used as gold standard for sensitivity and specificity determination. To estimate the sensitivity and specificity of LTT in a clinically defined series of patients with DRESS. Some 41 patients diagnosed with DRESS were included in the study. The results of the algorithm of the Spanish Pharmacovigilance System were used as the standard for a correct diagnosis of drug causality. A standard LTT was performed with involved drugs in acute or recovery samples. A stimulation index (SI) ≥2 in at least one concentration except for beta-lactams (SI ≥3) and contrast media (SI ≥4) was considered positive. Contingency tables and ROC curves were used for analysis. Sensitivity and specificity of LTT in the recovery phase of DRESS were 73% and 82%, respectively, whereas in the acute phase, they were only 40% and 30%, respectively. Comparison of skin tests and LTT confirmed a higher sensitivity and specificity of LTT in DRESS. LTT showed high sensitivity (S) and specificity (Sp) for anticonvulsants (S 100%, Sp 100%; P = .008), anti-TB drugs (S 87.5%, Sp 100%; P = .004), and beta-lactams (S 73%, Sp 100%; P = .001). ROC curves revealed that the best criteria for LTT positivity for all drugs are SI ≥2 in at least one concentration, increasing overall sensitivity to 80%, and for beta-lactams from 73% to 92%. LTT is a good diagnostic tool for drug causality in DRESS, mainly when performed in the recovery phase. © 2017 John Wiley & Sons Ltd.

  7. Assessment of medial coronoid disease in 180 canine lame elbow joints: a sensitivity and specificity comparison of radiographic, computed tomographic and arthroscopic findings.

    PubMed

    Villamonte-Chevalier, A; van Bree, H; Broeckx, Bjg; Dingemanse, W; Soler, M; Van Ryssen, B; Gielen, I

    2015-09-25

    Diagnostic imaging is essential to assess the lame patient; lesions of the elbow joint have traditionally been evaluated radiographically, however computed tomography (CT) has been suggested as a useful technique to diagnose various elbow pathologies. The primary objective of this study was to determine the sensitivity and specificity of CT to assess medial coronoid disease (MCD), using arthroscopy as gold standard. The secondary objective was to ascertain the radiographic sensitivity and specificity for MCD compared with CT. For this study 180 elbow joints were assessed, of which 141 had been examined with radiography, CT and arthroscopy; and 39 joints, had radiographic and CT assessment. Sensitivity and specificity were calculated for CT and radiographic findings using available statistical software. Sensitivity and specificity of CT using arthroscopy as gold standard resulted in high values for sensitivity (100 %) and specificity (93 %) for the assessment of MCD. For the radiographic evaluation, a sensitivity of 98 % and specificity of 64 - 69 % using CT as the technique of reference, were found. These results suggest that in case of doubt during radiographic assessment, CT could be used as a non-invasive technique to assess the presence of MCD. Based on the high sensitivity and specificity obtained in this study it has been considered that CT, rather than arthroscopy, is the preferred noninvasive technique to assess MCD lesions of the canine elbow joint.

  8. Physical Employment Standards for UK Firefighters

    PubMed Central

    Stevenson, Richard D.M.; Siddall, Andrew G.; Turner, Philip F.J.; Bilzon, James L.J.

    2017-01-01

    Objective: The aim of this study was to assess sensitivity and specificity of surrogate physical ability tests as predictors of criterion firefighting task performance and to identify corresponding minimum muscular strength and endurance standards. Methods: Fifty-one (26 male; 25 female) participants completed three criterion tasks (ladder lift, ladder lower, ladder extension) and three corresponding surrogate tests [one-repetition maximum (1RM) seated shoulder press; 1RM seated rope pull-down; repeated 28 kg seated rope pull-down]. Surrogate test standards were calculated that best identified individuals who passed (sensitivity; true positives) and failed (specificity; true negatives) criterion tasks. Results: Best sensitivity/specificity achieved were 1.00/1.00 for a 35 kg seated shoulder press, 0.79/0.92 for a 60 kg rope pull-down, and 0.83/0.93 for 23 repetitions of the 28 kg rope pull-down. Conclusions: These standards represent performance on surrogate tests commensurate with minimum acceptable performance of essential strength-based occupational tasks in UK firefighters. PMID:28045801

  9. Improving detection of HIV-associated cognitive impairment: Comparison of the International HIV Dementia Scale and a Brief Screening Battery

    PubMed Central

    de Almeida, Sergio Monteiro; Kamat, Rujvi; Cherner, Mariana; Umlauf, Anya; Ribeiro, Clea Elisa; de Pereira, Ana Paula; Franklin, Donald; Heaton, Robert K.; Ellis, Ronald J.

    2016-01-01

    Objectives The International HIV Dementia Scale (IHDS) was developed to screen for HIV-associated dementia (HAD), but it has been used more generally for HIV-associated neurocognitive disorder (HAND). This study sought to examine the accuracy of the IHDS in a cohort of Brazilian HIV-infected individuals and compare its performance to an alternative screening battery for detecting HAND. Methods 108 participants (including 60 HIV-infected persons), completed the IHDS and a gold standard neuropsychological (NP) battery of 17 tests. As alternative screening method, all possible three-test combinations from the NP battery were examined and a superiority index (a marker of specificity and sensitivity) was calculated. Results Sensitivity and specificity to HAND using the standard IHDS cutpoint of 10 were 36% and 75% respectively. The best balance between sensitivity and specificity was accomplished with a modified cutpoint of 11.5, which yielded sensitivity of 72% and specificity of 58%. The top two most sensitive test combinations, compared to the gold standard NP battery, were Trail Making Test A, WAIS-III Digit Symbol (DS) and HVLT-R Total Recall (sensitivity 91%, specificity 96%), and DS, BVMT-R Total Recall and Grooved Pegboard Test-Dominant Hand (sensitivity 94%, specificity 91%). Conclusions Both test combinations can be administered in under 10 minutes and were more accurate than the IHDS in classifying HIV+ participants as NP impaired or unimpaired. These data suggest that demographically corrected T-scores from commonly used NP measures with modest time and material demands can improve identification of patients with HAND who may benefit from a more extensive NP examination. PMID:27828876

  10. Improving Detection of HIV-Associated Cognitive Impairment: Comparison of the International HIV Dementia Scale and a Brief Screening Battery.

    PubMed

    de Almeida, Sérgio Monteiro; Kamat, Rujvi; Cherner, Mariana; Umlauf, Anya; Ribeiro, Clea E; de Pereira, Ana Paula; Franklin, Donald; Heaton, Robert K; Ellis, Ronald J

    2017-03-01

    The International HIV Dementia Scale (IHDS) was developed to screen for HIV-associated dementia, but it has been used more generally for HIV-associated neurocognitive disorder (HAND). This study sought to examine the accuracy of the IHDS in a cohort of Brazilian HIV-infected individuals and compare its performance to an alternative screening battery for detecting HAND. A total of 108 participants (including 60 HIV-infected persons) completed the IHDS and a gold standard neuropsychological (NP) battery of 17 tests. As alternative screening method, all possible 3-test combinations from the NP battery were examined and a superiority index (a marker of specificity and sensitivity) was calculated. Sensitivity and specificity to HAND using the standard IHDS cutpoint of 10 were 36% and 75%, respectively. The best balance between sensitivity and specificity was accomplished with a modified cutpoint of 11.5, which yielded sensitivity of 72% and specificity of 58%. The top two most sensitive test combinations, compared with the gold standard NP battery, were Trail Making Test A, Wechsler Adult Intelligence Scale III Digit Symbol and Hopkins Verbal Learning Test-Revised Total Recall (sensitivity 91%, specificity 96%), and Digit Symbol, Brief Visuospatial Memory Test-Revised Total Recall and Grooved Pegboard Test-dominant hand (sensitivity 94%, specificity 91%). Both test combinations can be administered in less than 10 minutes and were more accurate than the IHDS in classifying HIV+ participants as NP impaired or unimpaired. These data suggest that demographically corrected T-scores from commonly used NP measures with modest time and material demands can improve identification of patients with HAND who may benefit from a more extensive NP examination.

  11. Sensitivity and specificity of visual clinical assessment as compared to WHO 2006 standard and NCHS 1977 reference in measuring the growth status of Malaysian infants.

    PubMed

    Selamat, Rusidah; Zain, Fuziah; Raib, Junidah; Zakaria, Rosini; Marzuki, Mohd Shaffari; Ibrahim, Taziah Fatimah

    2011-12-01

    To study the validity of the visual clinical assessment of weight relative to length and length relative to age as compared to the World Health Organization (WHO) 2006 standard and National Center for Health Statistics (NCHS) 1977 reference in asssessing the physical growth of children younger than 1 year. A prospective cohort study was carried out among 684 infants attending goverment health clinics in 2 states in Malaysia. Body weight, length, and clinical assessment were measured on the same day for 9 visits, scheduled every month until 6 months of age and every 2 months until 12 months of age. All of the 3 z-scores for weight for age (WAZ), length for age (HAZ), and weight for length (WHZ) were calculated using WHO Anthro for Personal Computers software. The average sensitivity and specificity for the visual clinical assessment for the detection of thinness were higher using the WHO 2006 standard as compared with using NCHS 1977. However, the overall sensitivity of the visual clinical assessment for the detection of thin and lean children was lower from 1 month of age until a year as compared with the WHO 2006 standard and NCHS 1977 reference. The positive predictive value (PPV) for the visual clinical assessment versus the WHO 2006 standard was almost doubled as compared with the PPV of visual clinical assessment versus the NCHS 1977 reference. The overall average sensitivity, specificity, PPV, and negative predictive value for the detection of stunting was higher for visual clinical assessment versus the WHO 2006 standard as compared with visual clinical assessment versus the NCHS 1977 reference. The sensitivity and specificity of visual clinical assessment for the detection of wasting and stunting among infants are better for the WHO 2006 standard than the NCHS 1977 reference.

  12. Ultrasound Fracture Diagnosis in Space

    NASA Technical Reports Server (NTRS)

    Dulchavsky, Scott A.; Amponsah, David; Sargsyan, Ashot E.; Garcia, Kathleen M.; Hamilton, Douglas R.; vanHolsbeeck, Marnix

    2010-01-01

    Introduction: This ground-based investigation accumulated high-level clinical evidence on the sensitivity and specificity of point of care ultrasound performed by expert and novice users for the rapid diagnosis of musculoskeletal (MSK) injuries. We developed preliminary educational methodologies to provide just-in-time training of novice users by creating multi-media training tools and imaging procedures for non expert operators and evaluated the sensitivity and specificity of non-expert performed musculoskeletal ultrasound to diagnose acute injuries in a Level 1 Trauma Center. Methods: Patients with potential MSK injuries were identified in the emergency room. A focused MSK ultrasound was performed by expert operators and compared to standard radiographs. A repeat examination was performed by non-expert operators who received a short, just-in-time multimedia education aid. The sensitivity and specificity of the expert and novice ultrasound examinations were compared to gold standard radiography. Results: Over 800 patients were enrolled in this study. The sensitivity and specificity of expert performed ultrasound exceeded 98% for MSK injuries. Novice operators achieved 97% sensitivity and 99% specificity for targeted examinations with the greatest error in fractures involving the hand and foot. Conclusion: Point of care ultrasound is a sensitive and specific diagnostic test for MSK injury when performed by experts and just-in-time trained novice operators.

  13. Factors affecting the sensitivity and specificity of the Heidelberg Retina Tomograph parameters to glaucomatous progression in disc photographs.

    PubMed

    Saarela, Ville; Falck, Aura; Airaksinen, P Juhani; Tuulonen, Anja

    2012-03-01

    To evaluate the factors affecting the sensitivity and specificity of the stereometric optic nerve head (ONH) parameters of the Heidelberg Retina Tomograph (HRT) to glaucomatous progression in stereoscopic ONH photographs. The factors affecting the sensitivity and specificity of the vertical cup : disc ratio, the cup : disc area ratio, the cup volume, the rim area and a linear discriminant function to progression were analysed. These parameters were the best indicators of progression in a retrospective study of 476 eyes. The reference standard for progression was the masked evaluation of stereoscopic ONH photographs. The factors having the most significant effect on the sensitivity and specificity of the stereometric ONH parameters were the reference height difference and the mean topography standard deviation (TSD), indicating image quality. Also, the change in the TSD and age showed consistent, but variably significant, influence on all parameters tested. The sensitivity and specificity improved when there was little change in the reference height, the image quality was good and stable, and the patients were younger. The sensitivity and specificity of the vertical cup : disc ratio was improved by a large disc area and high baseline cup : disc area ratio. The rim area showed a better sensitivity and specificity for progression with a small disc area and low baseline cup : disc area ratio. The factors affecting the sensitivity and specificity of the stereometric ONH parameters to glaucomatous progression in disc photographs are essentially the same as those affecting the measurement variability of the HRT. © 2010 The Authors. Acta Ophthalmologica © 2010 Acta Ophthalmologica Scandinavica Foundation.

  14. Use of new World Health Organization child growth standards to assess how infant malnutrition relates to breastfeeding and mortality

    PubMed Central

    Vesel, Linda; Martines, Jose; Penny, Mary; Bhandari, Nita; Kirkwood, Betty R

    2010-01-01

    Abstract Objective To compare the estimated prevalence of malnutrition using the World Health Organization’s (WHO) child growth standards versus the National Center for Health Statistics’ (NCHS) growth reference, to examine the relationship between exclusive breastfeeding and malnutrition, and to determine the sensitivity and specificity of nutritional status indicators for predicting death during infancy. Methods A secondary analysis of data on 9424 mother–infant pairs in Ghana, India and Peru was conducted. Mothers and infants were enrolled in a trial of vitamin A supplementation during which the infants’ weight, length and feeding practices were assessed regularly. Malnutrition indicators were determined using WHO and NCHS growth standards. Findings The prevalence of stunting, wasting and underweight in infants aged < 6 months was higher with WHO than NCHS standards. However, the prevalence of underweight in infants aged 6–12 months was much lower with WHO standards. The duration of exclusive breastfeeding was not associated with malnutrition in the first 6 months of life. In infants aged < 6 months, severe underweight at the first immunization visit as determined using WHO standards had the highest sensitivity (70.2%) and specificity (85.8%) for predicting mortality in India. No indicator was a good predictor in Ghana or Peru. In infants aged 6–12 months, underweight at 6 months had the highest sensitivity and specificity for predicting mortality in Ghana (37.0% and 82.2%, respectively) and Peru (33.3% and 97.9% respectively), while wasting was the best predictor in India (sensitivity: 54.6%; specificity: 85.5%). Conclusion Malnutrition indicators determined using WHO standards were better predictors of mortality than those determined using NCHS standards. No association was found between breastfeeding duration and malnutrition at 6 months. Use of WHO child growth standards highlighted the importance of malnutrition in the first 6 months of life. PMID:20428352

  15. [Sensitivity and specificity of prick skin test with two concentrations of standardized extract of Culex quinquefasciatus in allergic children].

    PubMed

    Castro-Almarales, Raúl Lázaro; Álvarez-Castelló, Mirta; Ronquillo-Díaz, Mercedes; Rodríguez-Canosa, José S; González-León, Mayda; Navarro-Viltre, Bárbara I; Betancourt-Mesia, Daniel; Enríquez-Domínguez, Irene; Reyes-Zamora, Mary Carmen; Oliva-Díaz, Yunia; Mateo-Morejón, Maytee; Labrada-Rosado, Alexis

    2016-01-01

    Diagnostic options for immune reactions to mosquito bites are limited. In Cuba, IgE-mediated reactions are frequently related to Culex quinquefasciatus bite. To determine the sensitivity and specificity of skin prick test with two doses of standardized extract in nitrogen protein units (PNU of Culex quinquefasciatus (BIOCEN, Cuba). An analytical study was conducted on 100 children between 2 and 15 years old. Fifty atopic patients with a history of allergy to mosquito bite and positive specific serum IgE Culex quinquefasciatus and fifty atopic patients without a history of allergy to mosquito bite and negative specific serum IgE to Culex quinquefasciatus. Skin prick tests (SPT) were performed by duplicates on the forearms of the patients. Investigated doses were 100 PNU/mL and 10 PNU/mL. SPT with the highest concentration obtained a mean wheal size of 22.09 mm2 and for lower doses of 8.09 mm2, a statistically significant difference (p=0.001, Student's t test). Positive skin test correlated in 100% of patients with the presence of specific IgE. Testing with both doses showed a 94% of specificity and 88% of sensitivity. The diagnostic accuracy of SPT using both doses of standardized extract was similar, which justifies its use for diagnosis of sensitization to Culex quinquefasciatus in patients with symptoms of allergy to mosquito bite.

  16. Sensitivity and specificity of a digit symbol recognition trial in the identification of response bias.

    PubMed

    Kim, Nancy; Boone, Kyle B; Victor, Tara; Lu, Po; Keatinge, Carolyn; Mitchell, Cary

    2010-08-01

    Recently published practice standards recommend that multiple effort indicators be interspersed throughout neuropsychological evaluations to assess for response bias, which is most efficiently accomplished through use of effort indicators from standard cognitive tests already included in test batteries. The present study examined the utility of a timed recognition trial added to standard administration of the WAIS-III Digit Symbol subtest in a large sample of "real world" noncredible patients (n=82) as compared with credible neuropsychology clinic patients (n=89). Scores from the recognition trial were more sensitive in identifying poor effort than were standard Digit Symbol scores, and use of an equation incorporating Digit Symbol Age-Corrected Scaled Scores plus accuracy and time scores from the recognition trial was associated with nearly 80% sensitivity at 88.7% specificity. Thus, inclusion of a brief recognition trial to Digit Symbol administration has the potential to provide accurate assessment of response bias.

  17. Posturography and locomotor tests of dynamic balance after long-duration spaceflight.

    PubMed

    Cohen, Helen S; Kimball, Kay T; Mulavara, Ajitkumar P; Bloomberg, Jacob J; Paloski, William H

    2012-01-01

    The currently approved objective clinical measure of standing balance in astronauts after space flight is the Sensory Organization Test battery of computerized dynamic posturography. No tests of walking balance are currently approved for standard clinical testing of astronauts. This study determined the sensitivity and specificity of standing and walking balance tests for astronauts before and after long-duration space flight. Astronauts were tested on an obstacle avoidance test known as the Functional Mobility Test (FMT) and on the Sensory Organization Test using sway-referenced support surface motion with eyes closed (SOT 5) before and six months after (n=15) space flight on the International Space Station. They were tested two to seven days after landing. Scores on SOT tests decreased and scores on FMT increased significantly from pre- to post-flight. In other words, post-flight scores were worse than pre-flight scores. SOT and FMT scores were not significantly related. ROC analyses indicated supra-clinical cut-points for SOT 5 and for FMT. The standard clinical cut-point for SOT 5 had low sensitivity to post-flight astronauts. Higher cut-points increased sensitivity to post-flight astronauts but decreased specificity to pre-flight astronauts. Using an FMT cut-point that was moderately highly sensitive and highly specific plus SOT 5 at the standard clinical cut-point was no more sensitive than SOT 5, alone. FMT plus SOT 5 at higher cut-points was more specific and more sensitive. The total correctly classified was highest for FMT, alone, and for FMT plus SOT 5 at the highest cut-point. These findings indicate that standard clinical comparisons are not useful for identifying problems. Testing both standing and walking balance will be more likely to identify balance deficits.

  18. The Clinical Impact of Bet v 6 in Birch Pollen-Sensitized Patients.

    PubMed

    Gellrich, Donata; Eder, Katharina; San Nicoló, Marion; Berghaus, Alexander; Gröger, Moritz

    2017-01-01

    Bet v 6, a minor birch pollen allergen, is commercially available for allergen-specific IgE antibody testing. However, there is hardly any literature on the clinical impact of Bet v 6. The aim of the present study was to analyze if testing specific IgE against Bet v 6 can add valuable benefit to the standard diagnostics of birch pollen-sensitized patients, especially in patients with unknown sensitization-eliciting allergens. Birch pollen-sensitized patients with missing IgE reactivity against Bet v 1, 2, and 4 were tested for specific IgE antibodies against Bet v 6. For comparison, an equal number of randomly selected patients with birch pollen sensitization, regardless of their individual sensitization patterns, were tested for specific anti-Bet v 6. Of 57 cases with missing reactivity against the standard birch pollen allergens, 2 patients were positive for Bet v 6. In the representative sample, 3 patients showed specific IgE against Bet v 6 - resulting in a total prevalence of 5%. None of the Bet v 6-positive patients showed allergic symptoms after exposure to birch pollen or an oral allergy syndrome. An increased prevalence of asthma and a higher degree of sensitization were the only distinctive clinical features in Bet v 6-positive patients. Among birch pollen-sensitized patients, the prevalence of specific IgE against Bet v 6 is low. Further, sensitization to Bet v 6, which shows characteristics of a panallergen, remains clinically silent. Therefore, determination of anti-Bet v 6 is not considered useful in the clinical routine. © 2017 S. Karger AG, Basel.

  19. Deviance sensitivity in the auditory cortex of freely moving rats

    PubMed Central

    2018-01-01

    Deviance sensitivity is the specific response to a surprising stimulus, one that violates expectations set by the past stimulation stream. In audition, deviance sensitivity is often conflated with stimulus-specific adaptation (SSA), the decrease in responses to a common stimulus that only partially generalizes to other, rare stimuli. SSA is usually measured using oddball sequences, where a common (standard) tone and a rare (deviant) tone are randomly intermixed. However, the larger responses to a tone when deviant does not necessarily represent deviance sensitivity. Deviance sensitivity is commonly tested using a control sequence in which many different tones serve as the standard, eliminating the expectations set by the standard ('deviant among many standards'). When the response to a tone when deviant (against a single standard) is larger than the responses to the same tone in the control sequence, it is concluded that true deviance sensitivity occurs. In primary auditory cortex of anesthetized rats, responses to deviants and to the same tones in the control condition are comparable in size. We recorded local field potentials and multiunit activity from the auditory cortex of awake, freely moving rats, implanted with 32-channel drivable microelectrode arrays and using telemetry. We observed highly significant SSA in the awake state. Moreover, the responses to a tone when deviant were significantly larger than the responses to the same tone in the control condition. These results establish the presence of true deviance sensitivity in primary auditory cortex in awake rats. PMID:29874246

  20. Validation of diabetes mellitus and hypertension diagnosis in computerized medical records in primary health care

    PubMed Central

    2011-01-01

    Background Computerized Clinical Records, which are incorporated in primary health care practice, have great potential for research. In order to use this information, data quality and reliability must be assessed to prevent compromising the validity of the results. The aim of this study is to validate the diagnosis of hypertension and diabetes mellitus in the computerized clinical records of primary health care, taking the diagnosis criteria established in the most prominently used clinical guidelines as the gold standard against which what measure the sensitivity, specificity, and determine the predictive values. The gold standard for diabetes mellitus was the diagnostic criteria established in 2003 American Diabetes Association Consensus Statement for diabetic subjects. The gold standard for hypertension was the diagnostic criteria established in the Joint National Committee published in 2003. Methods A cross-sectional multicentre validation study of diabetes mellitus and hypertension diagnoses in computerized clinical records of primary health care was carried out. Diagnostic criteria from the most prominently clinical practice guidelines were considered for standard reference. Sensitivity, specificity, positive and negative predictive values, and global agreement (with kappa index), were calculated. Results were shown overall and stratified by sex and age groups. Results The agreement for diabetes mellitus with the reference standard as determined by the guideline was almost perfect (κ = 0.990), with a sensitivity of 99.53%, a specificity of 99.49%, a positive predictive value of 91.23% and a negative predictive value of 99.98%. Hypertension diagnosis showed substantial agreement with the reference standard as determined by the guideline (κ = 0.778), the sensitivity was 85.22%, the specificity 96.95%, the positive predictive value 85.24%, and the negative predictive value was 96.95%. Sensitivity results were worse in patients who also had diabetes and in those aged 70 years or over. Conclusions Our results substantiate the validity of using diagnoses of diabetes and hypertension found within the computerized clinical records for epidemiologic studies. PMID:22035202

  1. Diagnostic implications of a small-voxel reconstruction for loco-regional lymph node characterization in breast cancer patients using FDG-PET/CT.

    PubMed

    Koopman, Daniëlle; van Dalen, Jorn A; Arkies, Hester; Oostdijk, Ad H J; Francken, Anne Brecht; Bart, Jos; Slump, Cornelis H; Knollema, Siert; Jager, Pieter L

    2018-01-16

    We evaluated the diagnostic implications of a small-voxel reconstruction for lymph node characterization in breast cancer patients, using state-of-the-art FDG-PET/CT. We included 69 FDG-PET/CT scans from breast cancer patients. PET data were reconstructed using standard 4 × 4 × 4 mm 3 and small 2 × 2 × 2 mm 3 voxels. Two hundred thirty loco-regional lymph nodes were included, of which 209 nodes were visualised on PET/CT. All nodes were visually scored as benign or malignant, and SUV max and TB ratio (=SUV max /SUV background ) were measured. Final diagnosis was based on histological or imaging information. We determined the accuracy, sensitivity and specificity for both reconstruction methods and calculated optimal cut-off values to distinguish benign from malignant nodes. Sixty-one benign and 169 malignant lymph nodes were included. Visual evaluation accuracy was 73% (sensitivity 67%, specificity 89%) on standard-voxel images and 77% (sensitivity 78%, specificity 74%) on small-voxel images (p = 0.13). Across malignant nodes visualised on PET/CT, the small-voxel score was more often correct compared with the standard-voxel score (89 vs. 76%, p <  0.001). In benign nodes, the standard-voxel score was more often correct (89 vs. 74%, p = 0.04). Quantitative data were based on the 61 benign and 148 malignant lymph nodes visualised on PET/CT. SUVs and TB ratio were on average 3.0 and 1.6 times higher in malignant nodes compared to those in benign nodes (p <  0.001), on standard- and small-voxel PET images respectively. Small-voxel PET showed average increases in SUV max and TB ratio of typically 40% over standard-voxel PET. The optimal SUV max cut-off using standard-voxels was 1.8 (sensitivity 81%, specificity 95%, accuracy 85%) while for small-voxels, the optimal SUV max cut-off was 2.6 (sensitivity 78%, specificity 98%, accuracy 84%). Differences in accuracy were non-significant. Small-voxel PET/CT improves the sensitivity of visual lymph node characterization and provides a higher detection rate of malignant lymph nodes. However, small-voxel PET/CT also introduced more false-positive results in benign nodes. Across all nodes, differences in accuracy were non-significant. Quantitatively, small-voxel images require higher cut-off values. Readers have to adapt their reference standards.

  2. Diagnosis accuracy of two vision screeners for visual health surveillance of workers who use video display terminals

    PubMed Central

    Molina-Torres, María-José; Crespo, María-del-Mar Seguí; Francés, Ana Tauste; Lacarra, Blanca Lumbreras; Ronda-Pérez, Elena

    2016-01-01

    Objective: To compare the diagnostic accuracy of two vision screeners by a visual examination performed by an optometrist (gold standard) and to evaluate the concordance between both screeners and between each screener and the gold standard. Methods: This was a cross-sectional study that included computer workers who attended a routine yearly health examination. The study included administrative office workers (n=91) aged 50.2±7.9 years (mean±standard deviation), 69.2% of whom were women and 68.1% of whom used video display terminals (VDT) for >4 h/day. The routine visual examination included monocular and binocular distance visual acuity (VA), distance and near lateral phoria (LP), stereo acuity (SA), and color vision. Tests were repeated with Optec 6500 (by Stereo Optical) and Visiotest (by Essilor) screeners. Sensitivity, specificity, positive predictive values (PPV), negative predictive values (NPV), and false positive and negative rates were calculated. Kappa coefficient (κ) was used to measure the concordance of the screeners and the gold standard. Results: The sensitivity and specificity for monocular VA were over 80% for both vision screeners; PPV was below 25%. Sensitivity and specificity were lower for SA (55%-70%), PPV was 50%, and NPV was 75% for both screeners. For distance LP, sensitivity and PPV were <10% in both cases. The screeners differed in their values for near LP: Optec 6500 had higher sensitivity (43.5%), PPV (37.0%), and NPV (79.7%); whereas the Visiotest had higher specificity (83.8%). For color vision, Visiotest showed low sensitivity, low PPV, and high specificity. Visiotest obtained false positive rates that were lower or similar to Optec 6500, and both screeners obtained false negative rates below 50%. Both screeners showed poor concordance (κ<0.40). Conclusions: A high value for NPV would qualify both screeners as acceptable alternatives for visual health surveillance when used as a screening tool; patients with positive test results should be referred to a specialist. PMID:27488039

  3. [Validity of a standard questionnaire to assess physical activity for specific medical checkups and health guidance].

    PubMed

    Kawakami, Ryoko; Miyachi, Motohiko

    2010-10-01

    This study aimed to determine the validity of a standard questionnaire to assess amount of physical activity (PA) and cardiorespiratory fitness (VO2peak). A total of 483 men and women, aged 20 to 69 years, participated. The standard questionnaire included 3 items about exercise, PA, and walking speed. All questions were designed to require an answer of Yes or No. Subjects were classified into one of four groups regarding the number of Yes answers to the three questions, giving activity levels of 0 to 3. The amount of PA was measured objectively with a tn-axial accelerometer which could also calculate daily step counts, and the amounts of PA under 3 metabolic equivalents (METs) and at 3 METs or more. VO2peak. was measured by incremental cycle exercise tests with indirect calorimetry. The daily step counts, the amount of PA at 3 METs or more, and the VO2peak. were significantly higher in subjects who answered Yes to each question than in those who answered No. Sensitivity and specificity of each question were 62-73% and 45-71% for the amount of PA established with the "Exercise and Physical Activity Reference for Health Promotion 2006 (EPAR2006)". The sum of sensitivity and specificity was the highest when the cutoff value was activity level 2 (sensitivity 73%, specificity 68%). Sensitivity and specificity for VO2max established by EPAR2006 were lower than those for the amount of PA. These results suggest that only answering simple questions with a standard questionnaire is sufficient for estimation of PA levels for specific medical checkups and health guidance, even though the accuracy is somewhat limited.

  4. Species-specific diagnostic assays for Bonamia ostreae and B. exitiosa in European flat oyster Ostrea edulis: conventional, real-time and multiplex PCR.

    PubMed

    Ramilo, Andrea; Navas, J Ignacio; Villalba, Antonio; Abollo, Elvira

    2013-05-27

    Bonamia ostreae and B. exitiosa have caused mass mortalities of various oyster species around the world and co-occur in some European areas. The World Organisation for Animal Health (OIE) has included infections with both species in the list of notifiable diseases. However, official methods for species-specific diagnosis of either parasite have certain limitations. In this study, new species-specific conventional PCR (cPCR) and real-time PCR techniques were developed to diagnose each parasite species. Moreover, a multiplex PCR method was designed to detect both parasites in a single assay. The analytical sensitivity and specificity of each new method were evaluated. These new procedures were compared with 2 OIE-recommended methods, viz. standard histology and PCR-RFLP. The new procedures showed higher sensitivity than the OIE recommended ones for the diagnosis of both species. The sensitivity of tests with the new primers was higher using oyster gills and gonad tissue, rather than gills alone. The lack of a 'gold standard' prevented accurate estimation of sensitivity and specificity of the new methods. The implementation of statistical tools (maximum likelihood method) for the comparison of the diagnostic tests showed the possibility of false positives with the new procedures, although the absence of a gold standard precluded certainty. Nevertheless, all procedures showed negative results when used for the analysis of oysters from a Bonamia-free area.

  5. Circulating antigen tests and urine reagent strips for diagnosis of active schistosomiasis in endemic areas.

    PubMed

    Ochodo, Eleanor A; Gopalakrishna, Gowri; Spek, Bea; Reitsma, Johannes B; van Lieshout, Lisette; Polman, Katja; Lamberton, Poppy; Bossuyt, Patrick M M; Leeflang, Mariska M G

    2015-03-11

    Point-of-care (POC) tests for diagnosing schistosomiasis include tests based on circulating antigen detection and urine reagent strip tests. If they had sufficient diagnostic accuracy they could replace conventional microscopy as they provide a quicker answer and are easier to use. To summarise the diagnostic accuracy of: a) urine reagent strip tests in detecting active Schistosoma haematobium infection, with microscopy as the reference standard; and b) circulating antigen tests for detecting active Schistosoma infection in geographical regions endemic for Schistosoma mansoni or S. haematobium or both, with microscopy as the reference standard. We searched the electronic databases MEDLINE, EMBASE, BIOSIS, MEDION, and Health Technology Assessment (HTA) without language restriction up to 30 June 2014. We included studies that used microscopy as the reference standard: for S. haematobium, microscopy of urine prepared by filtration, centrifugation, or sedimentation methods; and for S. mansoni, microscopy of stool by Kato-Katz thick smear. We included studies on participants residing in endemic areas only. Two review authors independently extracted data, assessed quality of the data using QUADAS-2, and performed meta-analysis where appropriate. Using the variability of test thresholds, we used the hierarchical summary receiver operating characteristic (HSROC) model for all eligible tests (except the circulating cathodic antigen (CCA) POC for S. mansoni, where the bivariate random-effects model was more appropriate). We investigated heterogeneity, and carried out indirect comparisons where data were sufficient. Results for sensitivity and specificity are presented as percentages with 95% confidence intervals (CI). We included 90 studies; 88 from field settings in Africa. The median S. haematobium infection prevalence was 41% (range 1% to 89%) and 36% for S. mansoni (range 8% to 95%). Study design and conduct were poorly reported against current standards. Tests for S. haematobium Urine reagent test strips versus microscopyCompared to microscopy, the detection of microhaematuria on test strips had the highest sensitivity and specificity (sensitivity 75%, 95% CI 71% to 79%; specificity 87%, 95% CI 84% to 90%; 74 studies, 102,447 participants). For proteinuria, sensitivity was 61% and specificity was 82% (82,113 participants); and for leukocyturia, sensitivity was 58% and specificity 61% (1532 participants). However, the difference in overall test accuracy between the urine reagent strips for microhaematuria and proteinuria was not found to be different when we compared separate populations (P = 0.25), or when direct comparisons within the same individuals were performed (paired studies; P = 0.21).When tests were evaluated against the higher quality reference standard (when multiple samples were analysed), sensitivity was marginally lower for microhaematuria (71% vs 75%) and for proteinuria (49% vs 61%). The specificity of these tests was comparable. Antigen assayCompared to microscopy, the CCA test showed considerable heterogeneity; meta-analytic sensitivity estimate was 39%, 95% CI 6% to 73%; specificity 78%, 95% CI 55% to 100% (four studies, 901 participants). Tests for S. mansoni Compared to microscopy, the CCA test meta-analytic estimates for detecting S. mansoni at a single threshold of trace positive were: sensitivity 89% (95% CI 86% to 92%); and specificity 55% (95% CI 46% to 65%; 15 studies, 6091 participants) Against a higher quality reference standard, the sensitivity results were comparable (89% vs 88%) but specificity was higher (66% vs 55%). For the CAA test, sensitivity ranged from 47% to 94%, and specificity from 8% to 100% (4 studies, 1583 participants). Among the evaluated tests for S. haematobium infection, microhaematuria correctly detected the largest proportions of infections and non-infections identified by microscopy.The CCA POC test for S. mansoni detects a very large proportion of infections identified by microscopy, but it misclassifies a large proportion of microscopy negatives as positives in endemic areas with a moderate to high prevalence of infection, possibly because the test is potentially more sensitive than microscopy.

  6. BAYESIAN ANALYSIS TO EVALUATE TESTS FOR THE DETECTION OF MYCOBACTERIUM BOVIS INFECTION IN FREE-RANGING WILD BISON (BISON BISON ATHABASCAE) IN THE ABSENCE OF A GOLD STANDARD.

    PubMed

    Chapinal, Núria; Schumaker, Brant A; Joly, Damien O; Elkin, Brett T; Stephen, Craig

    2015-07-01

    We estimated the sensitivity and specificity of the caudal-fold skin test (CFT), the fluorescent polarization assay (FPA), and the rapid lateral-flow test (RT) for the detection of Mycobacterium bovis in free-ranging wild wood bison (Bison bison athabascae), in the absence of a gold standard, by using Bayesian analysis, and then used those estimates to forecast the performance of a pairwise combination of tests in parallel. In 1998-99, 212 wood bison from Wood Buffalo National Park (Canada) were tested for M. bovis infection using CFT and two serologic tests (FPA and RT). The sensitivity and specificity of each test were estimated using a three-test, one-population, Bayesian model allowing for conditional dependence between FPA and RT. The sensitivity and specificity of the combination of CFT and each serologic test in parallel were calculated assuming conditional independence. The test performance estimates were influenced by the prior values chosen. However, the rank of tests and combinations of tests based on those estimates remained constant. The CFT was the most sensitive test and the FPA was the least sensitive, whereas RT was the most specific test and CFT was the least specific. In conclusion, given the fact that gold standards for the detection of M. bovis are imperfect and difficult to obtain in the field, Bayesian analysis holds promise as a tool to rank tests and combinations of tests based on their performance. Combining a skin test with an animal-side serologic test, such as RT, increases sensitivity in the detection of M. bovis and is a good approach to enhance disease eradication or control in wild bison.

  7. Diagnostic value of different adherence measures using electronic monitoring and virologic failure as reference standards.

    PubMed

    Deschamps, Ann E; De Geest, Sabina; Vandamme, Anne-Mieke; Bobbaers, Herman; Peetermans, Willy E; Van Wijngaerden, Eric

    2008-09-01

    Nonadherence to antiretroviral therapy is a substantial problem in HIV and jeopardizes the success of treatment. Accurate measurement of nonadherence is therefore imperative for good clinical management but no gold standard has been agreed on yet. In a single-center prospective study nonadherence was assessed by electronic monitoring: percentage of doses missed and drug holidays and by three self reports: (1) a visual analogue scale (VAS): percentage of overall doses taken; (2) the Swiss HIV Cohort Study Adherence Questionnaire (SHCS-AQ): percentage of overall doses missed and drug holidays and (3) the European HIV Treatment Questionnaire (EHTQ): percentage of doses missed and drug holidays for each antiretroviral drug separately. Virologic failure prospectively assessed during 1 year, and electronic monitoring were used as reference standards. Using virologic failure as reference standard, the best results were for (1) the SHCS-AQ after electronic monitoring (sensitivity, 87.5%; specificity, 78.6%); (2) electronic monitoring (sensitivity, 75%; specificity, 85.6%), and (3) the VAS combined with the SHCS-AQ before electronic monitoring (sensitivity, 87.5%; specificity, 58.6%). The sensitivity of the complex EHTQ was less than 50%. Asking simple questions about doses taken or missed is more sensitive than complex questioning about each drug separately. Combining the VAS with the SHCS-AQ seems a feasible nonadherence measure for daily clinical practice. Self-reports perform better after electronic monitoring: their diagnostic value could be lower when given independently.

  8. Optimal search strategies for detecting health services research studies in MEDLINE

    PubMed Central

    Wilczynski, Nancy L.; Haynes, R. Brian; Lavis, John N.; Ramkissoonsingh, Ravi; Arnold-Oatley, Alexandra E.

    2004-01-01

    Background Evidence from health services research (HSR) is currently thinly spread through many journals, making it difficult for health services researchers, managers and policy-makers to find research on clinical practice guidelines and the appropriateness, process, outcomes, cost and economics of health care services. We undertook to develop and test search terms to retrieve from the MEDLINE database HSR articles meeting minimum quality standards. Methods The retrieval performance of 7445 methodologic search terms and phrases in MEDLINE (the test) were compared with a hand search of the literature (the gold standard) for each issue of 68 journal titles for the year 2000 (a total of 25 936 articles). We determined sensitivity, specificity and precision (the positive predictive value) of the MEDLINE search strategies. Results A majority of the articles that were classified as outcome assessment, but fewer than half of those in the other categories, were considered methodologically acceptable (no methodologic criteria were applied for cost studies). Combining individual search terms to maximize sensitivity, while keeping specificity at 50% or more, led to sensitivities in the range of 88.1% to 100% for several categories (specificities ranged from 52.9% to 97.4%). When terms were combined to maximize specificity while keeping sensitivity at 50% or more, specificities of 88.8% to 99.8% were achieved. When terms were combined to maximize sensitivity and specificity while minimizing the differences between the 2 measurements, most strategies for HSR categories achieved sensitivity and specificity of at least 80%. Interpretation Sensitive and specific search strategies were validated for retrieval of HSR literature from MEDLINE. These strategies have been made available for public use by the US National Library of Medicine at www.nlm.nih.gov/nichsr/hedges/search.html. PMID:15534310

  9. Modeling Canadian Quality Control Test Program for Steroid Hormone Receptors in Breast Cancer: Diagnostic Accuracy Study.

    PubMed

    Pérez, Teresa; Makrestsov, Nikita; Garatt, John; Torlakovic, Emina; Gilks, C Blake; Mallett, Susan

    The Canadian Immunohistochemistry Quality Control program monitors clinical laboratory performance for estrogen receptor and progesterone receptor tests used in breast cancer treatment management in Canada. Current methods assess sensitivity and specificity at each time point, compared with a reference standard. We investigate alternative performance analysis methods to enhance the quality assessment. We used 3 methods of analysis: meta-analysis of sensitivity and specificity of each laboratory across all time points; sensitivity and specificity at each time point for each laboratory; and fitting models for repeated measurements to examine differences between laboratories adjusted by test and time point. Results show 88 laboratories participated in quality control at up to 13 time points using typically 37 to 54 histology samples. In meta-analysis across all time points no laboratories have sensitivity or specificity below 80%. Current methods, presenting sensitivity and specificity separately for each run, result in wide 95% confidence intervals, typically spanning 15% to 30%. Models of a single diagnostic outcome demonstrated that 82% to 100% of laboratories had no difference to reference standard for estrogen receptor and 75% to 100% for progesterone receptor, with the exception of 1 progesterone receptor run. Laboratories with significant differences to reference standard identified with Generalized Estimating Equation modeling also have reduced performance by meta-analysis across all time points. The Canadian Immunohistochemistry Quality Control program has a good design, and with this modeling approach has sufficient precision to measure performance at each time point and allow laboratories with a significantly lower performance to be targeted for advice.

  10. A Comparative Study of Skin Prick Test versus Serum-Specific IgE Measurement in Indian Patients with Bronchial Asthma and Allergic Rhinitis.

    PubMed

    Kumar, Raj; Gupta, Nitesh; Kanuga, Jayesh; Kanuga, Mansi

    2015-01-01

    Skin prick testing (SPT) is the 'gold standard' in the assessment of allergic sensitivity to inhalant allergens. Serum-specific immunoglobulin E (SSIgE) measurement is a complementary test. SPT is performed with antigen extracts from India while SSIgE utilises extracts derived from European antigens. To evaluate the performance of allergic assessment by SSIgE against cockroach, housefly and mosquito aeroallergens which are frequently implicated in driving respiratory allergies in India considering SPT as the 'gold standard'. Twenty patients (mean age 28.5 years; range 15-50 years) diagnosed to have bronchial asthma and/or rhinitis underwent SPT. The SSIgE levels were obtained at the same visit. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of SSIgE testing were calculated using SPT as the 'gold standard'. The correlation between SPT grading and SSIgE levels was also evaluated. The sensitivity of SSIgE testing to each of the 3 aero-allergens was > 85%. The PPV of cockroach and mosquito SSIgE was > 85%; housefly SSIgE had PPV of 68.7%. The two tests were in agreement in 85% (cockroach), 90% (mosquito) and 55% (housefly). There was a significant correlation between the grades of SPT reactions and SSIgE levels. The SSIgE has higher sensitivity and PPV, but lacks specificity. Higher sensitivity with low specificity leads to increased false positive diagnosis of allergic disease. Unlike allergenic pollens, however, insect antigen extracts from different regions seem to give comparable results, and can thus, reliably be used in the evaluation of allergy.

  11. Development of responder criteria for multicomponent non-pharmacological treatment in fibromyalgia.

    PubMed

    Vervoort, Vera M; Vriezekolk, Johanna E; van den Ende, Cornelia H

    2017-01-01

    There is a need to identify individual treatment success in patients with fibromyalgia (FM) who received non-pharmacological treatment. The present study described responder criteria for multicomponent non-pharmacological treatment in FM, and estimated and compared their sensitivity and specificity. Candidate responder sets were 1) identified in literature; and 2) formulated by expert group consensus. All candidate responder sets were tested in a cohort of 129 patients with FM receiving multicomponent non-pharmacological treatment. We used two gold standards (both therapist's and patient's perspective), assessed at six months after the start of treatment. Seven responder sets were defined (three identified in literature and four formulated by expert group consensus), and comprised combinations of domains of 1) pain; 2) fatigue; 3) patient global assessment (PGA); 4) illness perceptions; 5) limitations in activities of daily living (ADL); and 6) sleep. The sensitivity and specificity of literature-based responder sets (n=3) ranged between 17%-99% and 15%-95% respectively, whereas the expert-based responder sets (n=4) performed slightly better with regard to sensitivity (range 41%-81%) and specificity (range 50%-96%). Of the literature-based responder sets the OMERACT-OARSI responder set with patient's gold standard performed best (sensitivity 63%, specificity 75% and ROC area = 0.69). Overall, the expert-based responder set comprising the domains illness perceptions and limitations in ADL with patient's gold standard performed best (sensitivity 47%, specificity 96% and ROC area = 0.71). We defined sets of responder criteria for multicomponent non-pharmacological treatment in fibromyalgia. Further research should focus on the validation of those sets with acceptable performance.

  12. Sensitivity and specificity of modified 100-g oral glucose tolerance tests for diagnosis of gestational diabetes mellitus.

    PubMed

    Hansarikit, Jarunee; Manotaya, Saknan

    2011-05-01

    To study the sensitivity and specificity of the modified 100-g oral glucose tolerance test for diagnosis of gestational diabetes mellitus (GDM). Medical records of pregnant women attending the antenatal clinic of King Chulalongkorn Memorial Hospital, Thailand, who underwent a 100-g oral glucose tolerance test (OGTT) during March 2004 to September 2009, were retrospectively reviewed. Three modified criteria were proposed for diagnosis of GDM. The screening efficacy of the modified criteria were assessed, using the National Diabetes Data Group (NDDG) criterion as gold standard. A total of 729 records were reviewed, 511 were included for analysis. Using the NDDG criterion as the gold standard, the modified II criterion has the highest sensitivity of 96.8%, and the highest accuracy of 90.8%. The modified II criterion can detect the same proportion of maternal and neonatal complications, compared to the NDDG criterion. The modified II criterion, using the fasting plasma glucose and 2-hour plasma glucose measurements, showed high sensitivity and accuracy, with moderate specificity for diagnosis of GDM. Its potential use as an alternative to standard 100-g OGTT should be evaluated in the prospective study.

  13. A new responder criterion (relative effect per patient (REPP) > 0.2) externally validated in a large total hip replacement multicenter cohort (EUROHIP).

    PubMed

    Huber, J; Hüsler, J; Dieppe, P; Günther, K P; Dreinhöfer, K; Judge, A

    2016-03-01

    To validate a new method to identify responders (relative effect per patient (REPP) >0.2) using the OMERACT-OARSI criteria as gold standard in a large multicentre sample. The REPP ([score before - after treatment]/score before treatment) was calculated for 845 patients of a large multicenter European cohort study for THR. The patients with a REPP >0.2 were defined as responders. The responder rate was compared to the gold standard (OMERACT-OARSI criteria) using receiver operator characteristic (ROC) curve analysis for sensitivity, specificity and percentage of appropriately classified patients. With the criterion REPP>0.2 85.4% of the patients were classified as responders, applying the OARSI-OMERACT criteria 85.7%. The new method had 98.8% sensitivity, 94.2% specificity and 98.1% of the patients were correctly classified compared to the gold standard. The external validation showed a high sensitivity and also specificity of a new criterion to identify a responder compared to the gold standard method. It is simple and has no uncertainties due to a single classification criterion. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  14. Standardization of a two-step real-time polymerase chain reaction based method for species-specific detection of medically important Aspergillus species.

    PubMed

    Das, P; Pandey, P; Harishankar, A; Chandy, M; Bhattacharya, S; Chakrabarti, A

    2017-01-01

    Standardization of Aspergillus polymerase chain reaction (PCR) poses two technical challenges (a) standardization of DNA extraction, (b) optimization of PCR against various medically important Aspergillus species. Many cases of aspergillosis go undiagnosed because of relative insensitivity of conventional diagnostic methods such as microscopy, culture or antigen detection. The present study is an attempt to standardize real-time PCR assay for rapid sensitive and specific detection of Aspergillus DNA in EDTA whole blood. Three nucleic acid extraction protocols were compared and a two-step real-time PCR assay was developed and validated following the recommendations of the European Aspergillus PCR Initiative in our setup. In the first PCR step (pan-Aspergillus PCR), the target was 28S rDNA gene, whereas in the second step, species specific PCR the targets were beta-tubulin (for Aspergillus fumigatus, Aspergillus flavus, Aspergillus terreus), gene and calmodulin gene (for Aspergillus niger). Species specific identification of four medically important Aspergillus species, namely, A. fumigatus, A. flavus, A. niger and A. terreus were achieved by this PCR. Specificity of the PCR was tested against 34 different DNA source including bacteria, virus, yeast, other Aspergillus sp., other fungal species and for human DNA and had no false-positive reactions. The analytical sensitivity of the PCR was found to be 102 CFU/ml. The present protocol of two-step real-time PCR assays for genus- and species-specific identification for commonly isolated species in whole blood for diagnosis of invasive Aspergillus infections offers a rapid, sensitive and specific assay option and requires clinical validation at multiple centers.

  15. Sensitivity and specificity of Norwegian optometrists' evaluation of diabetic retinopathy in single-field retinal images - a cross-sectional experimental study.

    PubMed

    Sundling, Vibeke; Gulbrandsen, Pål; Straand, Jørund

    2013-01-10

    In the working age group, diabetic retinopathy is a leading cause of visual impairment. Regular eye examinations and early treatment of retinopathy can prevent visual loss, so screening for diabetic retinopathy is cost-effective. Dilated retinal digital photography with the additional use of ophthalmoscopy is the most effective and robust method of diabetic retinopathy screening. The aim of this study was to estimate the sensitivity and specificity of diabetic retinopathy screening when performed by Norwegian optometrists. This study employed a cross-sectional experimental design. Seventy-four optometrists working in private optometric practice were asked to screen 14 single-field retinal images for possible diabetic retinopathy. The screening was undertaken using a web-based visual identification and management of ophthalmological conditions (VIMOC) examination. The images used in the VIMOC examination were selected from a population survey and had been previously examined by two independent ophthalmologists. In order to establish a "gold standard", images were only chosen for use in the VIMOC examination if they had elicited diagnostic agreement between the two independent ophthalmologists. To reduce the possibility of falsely high specificity occurring by chance, half the presented images were of retinas that were not affected by diabetic retinopathy. Sensitivity and specificity for diabetic retinopathy was calculated with 95% confidence intervals (CIs). The mean (95%CI) sensitivity for identifying eyes with any diabetic retinopathy was 67% (62% to 72%). The mean (95%CI) specificity for identifying eyes without diabetic retinopathy was 84% (80% to 89%). The mean (95%CI) sensitivity for identifying eyes with mild non-proliferative diabetic retinopathy or moderate non-proliferative diabetes was 54% (47% to 61%) and 100%, respectively. Only four optometrists (5%) met the required standard of at least 80% sensitivity and 95% specificity that has been previously set for diabetic retinopathy screening programmes. The evaluation of retinal images for diabetic retinopathy by Norwegian optometrists does not meet the required screening standard of at least 80% sensitivity and 95% specificity. The introduction of measures to improve this situation could have implications for both formal optometric training and continuing optometric professional education.

  16. Geriatric-specific triage criteria are more sensitive than standard adult criteria in identifying need for trauma center care in injured older adults.

    PubMed

    Ichwan, Brian; Darbha, Subrahmanyam; Shah, Manish N; Thompson, Laura; Evans, David C; Boulger, Creagh T; Caterino, Jeffrey M

    2015-01-01

    We evaluate the sensitivity of Ohio's 2009 emergency medical services (EMS) geriatric trauma triage criteria compared with the previous adult triage criteria in identifying need for trauma center care among older adults. We studied a retrospective cohort of injured patients aged 16 years or older in the 2006 to 2011 Ohio Trauma Registry. Patients aged 70 years or older were considered geriatric. We identified whether each patient met the geriatric and the adult triage criteria. The outcome measure was need for trauma center care, defined by surrogate markers: Injury Severity Score greater than 15, operating room in fewer than 48 hours, any ICU stay, and inhospital mortality. We calculated sensitivity and specificity of both triage criteria for both age groups. We included 101,577 patients; 33,379 (33%) were geriatric. Overall, 57% of patients met adult criteria and 68% met geriatric criteria. Using Injury Severity Score, for older adults geriatric criteria were more sensitive for need for trauma center care (93%; 95% confidence interval [CI] 92% to 93%) than adult criteria (61%; 95% CI 60% to 62%). Geriatric criteria decreased specificity in older adults from 61% (95% CI 61% to 62%) to 49% (95% CI 48% to 49%). Geriatric criteria in older adults (93% sensitivity, 49% specificity) performed similarly to the adult criteria in younger adults (sensitivity 87% and specificity 44%). Similar patterns were observed for other outcomes. Standard adult EMS triage guidelines provide poor sensitivity in older adults. Ohio's geriatric trauma triage guidelines significantly improve sensitivity in identifying Injury Severity Score and other surrogate markers of the need for trauma center care, with modest decreases in specificity for older adults. Copyright © 2014 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

  17. Differentiation between diverticulitis and colorectal cancer: quantitative CT perfusion measurements versus morphologic criteria--initial experience.

    PubMed

    Goh, Vicky; Halligan, Steve; Taylor, Stuart A; Burling, David; Bassett, Paul; Bartram, Clive I

    2007-02-01

    To determine whether computed tomographic (CT) perfusion measurements in prospectively recruited patients can be used to differentiate between diverticulitis and colorectal cancer and to compare this discrimination with that of standard morphologic criteria. After institutional review board approval and written informed consent were obtained, 60 patients (24 men, 36 women; mean age, 69 years; range, 33.5-90.4 years; 20 patients with cancer, 20 with diverticulitis, and 20 with inactive diverticular disease) underwent CT perfusion imaging at the level of the colonic abnormality, and perfusion parameters were calculated. Analysis of variance was used to investigate any differences in perfusion between the patient groups. Two independent observers also analyzed an abdominopelvic CT study obtained immediately after the CT perfusion study and noted standard morphologic criteria for differential diagnosis. The sensitivity and specificity of CT perfusion measurements for determining the diagnostic category were compared with morphologic criteria by means of multivariate analysis to identify the most discriminatory criteria. Mean blood volume, blood flow, transit time, and permeability were significantly different between patients with cancer and those with diverticulitis (P < .0001); patients with cancer had the highest blood volume, blood flow, and permeability and the shortest transit time. The most discriminatory criteria for determining diagnostic category were blood volume, transit time, permeability, and presence of pericolonic nodes (P = .05, .02, .04, and .02, respectively). Blood volume and blood flow each had a sensitivity of 80% and had specificity of 70% and 75%, respectively, for cancer in comparison with standard morphologic criteria: less than 5 cm of bowel involvement (45% sensitivity, 95% specificity), presence of a mass (85% sensitivity, 90% specificity), pericolonic inflammation (75% sensitivity, 5% specificity), and pericolonic nodes (90% sensitivity, 45% specificity). CT perfusion measurements enable differentiation and better discrimination, in comparison with morphologic criteria, between cancer and diverticulitis. (c) RSNA, 2007.

  18. Sensitivity and specificity of the American College of Rheumatology 1987 criteria for the diagnosis of rheumatoid arthritis according to disease duration: a systematic literature review and meta-analysis.

    PubMed

    Banal, F; Dougados, M; Combescure, C; Gossec, L

    2009-07-01

    To evaluate the ability of the widely used ACR set of criteria (both list and tree format) to diagnose RA compared with expert opinion according to disease duration. A systematic literature review was conducted in PubMed and Embase databases. All articles reporting the prevalence of RA according to ACR criteria and expert opinion in cohorts of early (<1 year duration) or established (>1 year) arthritis were analysed to calculate the sensitivity and specificity of ACR 1987 criteria against the "gold standard" (expert opinion). A meta-analysis using a summary receiver operating characteristic (SROC) curve was performed and pooled sensitivity and specificity were calculated with confidence intervals. Of 138 publications initially identified, 19 were analysable (total 7438 patients, 3883 RA). In early arthritis, pooled sensitivity and specificity of the ACR set of criteria were 77% (68% to 84%) and 77% (68% to 84%) in the list format versus 80% (72% to 88%) and 33% (24% to 43%) in the tree format. In established arthritis, sensitivity and specificity were respectively 79% (71% to 85%) and 90% (84% to 94%) versus 80% (71% to 85%) and 93% (86% to 97%). The SROC meta-analysis confirmed the statistically significant differences, suggesting that diagnostic performances of ACR list criteria are better in established arthritis. The specificity of ACR 1987 criteria in early RA is low, and these criteria should not be used as diagnostic tools. Sensitivity and specificity in established RA are higher, which reflects their use as classification criteria gold standard.

  19. Detection of Echinococcus multilocularis by MC-PCR: evaluation of diagnostic sensitivity and specificity without gold standard.

    PubMed

    Wahlström, Helene; Comin, Arianna; Isaksson, Mats; Deplazes, Peter

    2016-01-01

    A semi-automated magnetic capture probe-based DNA extraction and real-time PCR method (MC-PCR), allowing for a more efficient large-scale surveillance of Echinococcus multilocularis occurrence, has been developed. The test sensitivity has previously been evaluated using the sedimentation and counting technique (SCT) as a gold standard. However, as the sensitivity of the SCT is not 1, test characteristics of the MC-PCR was also evaluated using latent class analysis, a methodology not requiring a gold standard. Test results, MC-PCR and SCT, from a previous evaluation of the MC-PCR using 177 foxes shot in the spring (n=108) and autumn 2012 (n=69) in high prevalence areas in Switzerland were used. Latent class analysis was used to estimate the test characteristics of the MC-PCR. Although it is not the primary aim of this study, estimates of the test characteristics of the SCT were also obtained. This study showed that the sensitivity of the MC-PCR was 0.88 [95% posterior credible interval (PCI) 0.80-0.93], which was not significantly different than the SCT, 0.83 (95% PCI 0.76-0.88), which is currently considered as the gold standard. The specificity of both tests was high, 0.98 (95% PCI 0.94-0.99) for the MC-PCR and 0.99 (95% PCI 0.99-1) for the SCT. In a previous study, using fox scats from a low prevalence area, the specificity of the MC-PCR was higher, 0.999% (95% PCI 0.997-1). One reason for the lower estimate of the specificity in this study could be that the MC-PCR detects DNA from infected but non-infectious rodents eaten by foxes. When using MC-PCR in low prevalence areas or areas free from the parasite, a positive result in the MC-PCR should be regarded as a true positive. The sensitivity of the MC-PCR (0.88) was comparable to the sensitivity of SCT (0.83).

  20. A hybrid model for combining case-control and cohort studies in systematic reviews of diagnostic tests

    PubMed Central

    Chen, Yong; Liu, Yulun; Ning, Jing; Cormier, Janice; Chu, Haitao

    2014-01-01

    Systematic reviews of diagnostic tests often involve a mixture of case-control and cohort studies. The standard methods for evaluating diagnostic accuracy only focus on sensitivity and specificity and ignore the information on disease prevalence contained in cohort studies. Consequently, such methods cannot provide estimates of measures related to disease prevalence, such as population averaged or overall positive and negative predictive values, which reflect the clinical utility of a diagnostic test. In this paper, we propose a hybrid approach that jointly models the disease prevalence along with the diagnostic test sensitivity and specificity in cohort studies, and the sensitivity and specificity in case-control studies. In order to overcome the potential computational difficulties in the standard full likelihood inference of the proposed hybrid model, we propose an alternative inference procedure based on the composite likelihood. Such composite likelihood based inference does not suffer computational problems and maintains high relative efficiency. In addition, it is more robust to model mis-specifications compared to the standard full likelihood inference. We apply our approach to a review of the performance of contemporary diagnostic imaging modalities for detecting metastases in patients with melanoma. PMID:25897179

  1. [Sensitivity and specificity of flicker perimetry with Pulsar. Comparison with achromatic (white-on-white) perimetry in glaucoma patients].

    PubMed

    Göbel, K; Erb, C

    2013-02-01

    The early detection of functional glaucoma damage plays an increasingly more central role in the diagnosis and treatment of glaucoma disease. Using selective perimetry detection of early glaucomatous defects is more likely and one of these methods is flicker perimetry with Pulsar. Flicker perimetry is used to analyze the temporal visual function in combination with spatial resolution and contrast sensitivity as opposed to standard automated perimetry which measures the differential light sensitivity with a non-specific stimulus. This study showed a higher sensitivity and specificity of Pulsar perimetry in comparison to achromatic perimetry in glaucoma patients.

  2. Designing Medical Tests: The Other Side of Bayes' Theorem

    ERIC Educational Resources Information Center

    Ross, Andrew M.

    2012-01-01

    To compute the probability of having a disease, given a positive test result, is a standard probability problem. The sensitivity and specificity of the test must be given and the prevalence of the disease. We ask how a test-maker might determine the tradeoff between sensitivity and specificity. Adding hypothetical costs for detecting or failing to…

  3. Seeking a valid gold standard for an innovative, dialect-neutral language test.

    PubMed

    Pearson, Barbara Zurer; Jackson, Janice E; Wu, Haotian

    2014-04-01

    PURPOSE In this study, the authors explored alternative gold standards to validate an innovative, dialect-neutral language assessment. METHOD Participants were 78 African American children, ages 5;0 (years;months) to 6;11. Twenty participants had previously been identified as having language impairment. The Diagnostic Evaluation of Language Variation-Norm Referenced (DELV-NR; Seymour, Roeper, & J. de Villiers, 2005) was administered, and concurrent language samples (LSs) were collected. Using LS profiles as the gold standard, sensitivity, specificity, and other measures of diagnostic accuracy were compared for diagnoses made from the DELV-NR and participants' clinical status prior to recruitment. In a second analysis, the authors used results from the first analysis to make evidence-based adjustments in the estimates of DELV-NR diagnostic accuracy. RESULTS Accuracy of the DELV-NR relative to LS profiles was greater than that of prior diagnoses, indicating that the DELV-NR was an improvement over preexisting diagnoses for this group. Specificity met conventional standards, but sensitivity was somewhat low. Reanalysis using the positive and negative predictive power of the preexisting diagnosis in a discrepant-resolution procedure revealed that estimates for sensitivity and specificity for the DELV-NR were .85 and .93, respectively. CONCLUSION The authors found that, even after making allowances for the imperfection of available gold standards, clinical decisions made with the DELV-NR achieved high values on conventional measures of diagnostic accuracy.

  4. Screening for alcohol use disorders and at-risk drinking in the general population: psychometric performance of three questionnaires.

    PubMed

    Rumpf, Hans-Jürgen; Hapke, Ulfert; Meyer, Christian; John, Ulrich

    2002-01-01

    Most screening questionnaires are developed in clinical settings and there are few data on their performance in the general population. This study provides data on the area under the receiver-operating characteristic (ROC) curve, sensitivity, specificity, and internal consistency of the Alcohol Use Disorders Identification Test (AUDIT), the consumption questions of the AUDIT (AUDIT-C) and the Lübeck Alcohol Dependence and Abuse Screening Test (LAST) among current drinkers (n = 3551) of a general population sample in northern Germany. Alcohol dependence and misuse according to DSM-IV and at-risk drinking served as gold standards to assess sensitivity and specificity and were assessed with the Munich-Composite Diagnostic Interview (M-CIDI). AUDIT and LAST showed insufficient sensitivity for at-risk drinking and alcohol misuse using standard cut-off scores, but satisfactory detection rates for alcohol dependence. The AUDIT-C showed low specificity in all criterion groups with standard cut-off. Adjusted cut-points are recommended. Among a subsample of individuals with previous general hospital admission in the last year, all questionnaires showed higher internal consistency suggesting lower reliability in non-clinical samples. In logistic regression analyses, having had a hospital admission increased the sensitivity in detecting any criterion group of the LAST, and the number of recent general practice visits increased the sensitivity of the AUDIT in detecting alcohol misuse. Women showed lower scores and larger areas under the ROC curves. It is concluded that setting specific instruments (e.g. primary care or general population) or adjusted cut-offs should be used.

  5. Carbon-14 urea breath test: does it work in patients with partial gastric resection?

    PubMed

    Dede, Fuat; Civen, Hüseyin; Dane, Faysal; Aliustaoglu, Mehmet; Turhal, Serdar; Turoglu, Halil Turgut; Inanir, Sabahat

    2015-11-01

    The diagnostic value of Carbon-14 urea breath test (C-14 UBT) in the detection of Helicobacter pylori (H. pylori) infection in non-operated patients has been proved. However, the efficacy of C-14 UBT in patients with partial gastric resection (PGR) has not been evaluated yet. Herein, the results of the C-14 UBT and H. pylori stool antigen test (HpSAT) in this patient group were compared with the endoscopic findings. Multi-breath samples C-14 UBT and HpSAT were performed in all patients on the same day. Histology was used as a gold standard for testing C-14 UBT and HpSAT diagnostic efficacies. 30 patients (mean age: 54.6 ± 11 year) with PGR were included. The sensitivity and specificity of standard C-14 UBT were 29 and 100 %, respectively. When breath samples were collected at 20th min, and >35 CPM was selected as radioactivity threshold, the sensitivity raised to 86 % without any loss of specificity. The specificity and sensitivity of the HpSAT were 71 and 96 %, respectively. The sensitivity of the standard C-14 UBT was very poor for patients with PGR, and results of HpSAT were superior in this population. Certain modifications are needed if C-14 UBT is to be used in PGR patients.

  6. Indication for Computed Tomography Scan in Shoulder Instability: Sensitivity and Specificity of Standard Radiographs to Predict Bone Defects After Traumatic Anterior Glenohumeral Instability.

    PubMed

    Delage Royle, Audrey; Balg, Frédéric; Bouliane, Martin J; Canet-Silvestri, Fanny; Garant-Saine, Laurianne; Sheps, David M; Lapner, Peter; Rouleau, Dominique M

    2017-10-01

    Quantifying glenohumeral bone loss is key in preoperative surgical planning for a successful Bankart repair. Simple radiographs can accurately measure bone defects in cases of recurrent shoulder instability. Cohort study (diagnosis); Level of evidence, 2. A true anteroposterior (AP) view, alone and in combination with an axillary view, was used to evaluate the diagnostic properties of radiographs compared with computed tomography (CT) scan, the current gold standard, to predict significant bone defects in 70 patients. Sensitivity, specificity, and positive and negative predictive values were evaluated and compared. Detection of glenoid bone loss on plain film radiographs, with and without axillary view, had a sensitivity of 86% for both views and a specificity of 73% and 64% with and without the axillary view, respectively. For detection of humeral bone loss, the sensitivity was 8% and 17% and the specificity was 98% and 91% with and without the axillary view, respectively. Regular radiographs would have missed 1 instance of significant bone loss on the glenoid side and 20 on the humeral side. Interobserver reliabilities were moderate for glenoid detection (κ = 0.473-0.503) and poor for the humeral side (κ = 0.278-0.336). Regular radiographs showed suboptimal sensitivity, specificity, and reliability. Therefore, CT scan should be considered in the treatment algorithm for accurate quantification of bone loss to prevent high rates of recurrent instability.

  7. Intraoperative assessment of the stability of the distal tibiofibular joint in supination-external rotation injuries of the ankle: sensitivity, specificity, and reliability of two clinical tests.

    PubMed

    Pakarinen, Harri; Flinkkilä, Tapio; Ohtonen, Pasi; Hyvönen, Pekka; Lakovaara, Martti; Leppilahti, Juhana; Ristiniemi, Jukka

    2011-11-16

    This study was designed to assess the sensitivity, specificity, and interobserver reliability of the hook test and the stress test for the intraoperative diagnosis of instability of the distal tibiofibular joint following fixation of ankle fractures resulting from supination-external rotation forces. We conducted a prospective study of 140 patients with an unstable unilateral ankle fracture resulting from a supination-external rotation mechanism (Lauge-Hansen SE). After internal fixation of the malleolar fracture, a hook test and an external rotation stress test under fluoroscopy were performed independently by the lead surgeon and assisting surgeon, followed by a standardized 7.5-Nm external rotation stress test of each ankle under fluoroscopy. A positive stress test result was defined as a side-to-side difference of >2 mm in the tibiotalar or the tibiofibular clear space on mortise radiographs. The sensitivity and specificity of each test were calculated with use of the standardized 7.5-Nm external rotation stress test as a reference. Twenty-four (17%) of the 140 patients had a positive standardized 7.5-Nm external rotation stress test after internal fixation of the malleolar fracture. The hook test had a sensitivity of 0.25 (95% confidence interval, 0.12 to 0.45) and a specificity of 0.98 (95% confidence interval, 0.94 to 1.0) for the detection of the same instabilities. The external rotation stress test had a sensitivity of 0.58 (95% confidence interval, 0.39 to 0.76) and a specificity of 0.96 (95% confidence interval, 0.90 to 0.98). Both tests had excellent interobserver reliability, with 99% agreement for the hook test and 98% for the stress test. Interobserver agreement for the hook test and the clinical stress test was excellent, but the sensitivity of these tests was insufficient to adequately detect instability of the syndesmosis intraoperatively.

  8. [Functional endoscopic evaluation of swallowing in infants with deglutition disorders].

    PubMed

    Partida-Justo, I; Israel Grijalva-Otero, J E; Ramírez-Figueroa, J L; Sepúlveda-Vildosola, A C; Zurita-Cruz, J N

    2017-10-25

    Functional endoscopic evaluation of swallowing (FEES) is a recognized method for Deglutition Disorders (DD) in adults, with anecdotal experience in children, obtaining not conclusive results. To compare the accuracy of test FEES in infants with high suspicion of altered DD seen in a third level hospital with the gold standard Videofluoroscopic (VF). The results and findings by FEES and VF of 66 children with clinical diagnosis of DD were compared. An estimate of the sensitivity and specificity of FEES was performed. As well as calculating positive predictive value (PPV), negative predictive value (NPV) and likelihood ratios. 60 patients enrolled, 4 and FEES showed high sensitivity to identify the presence of aspiration and penetration (9 98%) and high specificity for the arrest of spillage and waste (94% and 95%). Gastroesophageal reflux to make the diagnosis of DD with FEES had a sensitivity of 80% and specificity of 84%. Spill and penetration had the highest agreement with respect to the gold standard of 0.81. FEES in infants diagnosed with DD had a sensitivity of 80.8% and specificity 85.3%. 0696 concordance regarding to the VFD in the diagnosis of DD, and to identify suction stroke had a kappa of 0815.

  9. Comparison of isolated-check visual evoked potential and standard automated perimetry in early glaucoma and high-risk ocular hypertension

    PubMed Central

    Chen, Xiang-Wu; Zhao, Ying-Xi

    2017-01-01

    AIM To compare the diagnostic performance of isolated-check visual evoked potential (icVEP) and standard automated perimetry (SAP), for evaluating the application values of icVEP in the detection of early glaucoma. METHODS Totally 144 subjects (288 eyes) were enrolled in this study. icVEP testing was performed with the Neucodia visual electrophysiological diagnostic system. A 15% positive-contrast (bright) condition pattern was used in this device to differentiate between glaucoma patients and healthy control subjects. Signal-to-noise ratios (SNR) were derived based on a multivariate statistic. The eyes were judged as abnormal if the test yielded an SNR≤1. SAP testing was performed with the Humphrey Field Analyzer II. The visual fields were deemed as abnormality if the glaucoma hemifield test results outside normal limits; or the pattern standard deviation with P<0.05; or the cluster of three or more non-edge points on the pattern deviation plot in a single hemifield with P<0.05, one of which must have a P<0.01. Disc photographs were graded as either glaucomatous optic neuropathy or normal by two experts who were masked to all other patient information. Moorfields regression analysis (MRA) used as a separate diagnostic classification was performed by Heidelberg retina tomograph (HRT). RESULTS When the disc photograph grader was used as diagnostic standard, the sensitivity for SAP and icVEP was 32.3% and 38.5% respectively and specificity was 82.3% and 77.8% respectively. When the MRA Classifier was used as the diagnostic standard, the sensitivity for SAP and icVEP was 48.6% and 51.4% respectively and specificity was 84.1% and 78.0% respectively. When the combined structural assessment was used as the diagnostic standard, the sensitivity for SAP and icVEP was 59.2% and 53.1% respectively and specificity was 84.2% and 84.6% respectivlely. There was no statistical significance between the sensitivity or specificity of SAP and icVEP, regardless of which diagnostic standard was based on. CONCLUSION The diagnostic performance of icVEP is not better than that of SAP in the detection of early glaucoma. PMID:28503434

  10. Bacteriophage-based assays for the rapid detection of rifampicin resistance in Mycobacterium tuberculosis: a meta-analysis.

    PubMed

    Pai, Madhukar; Kalantri, Shriprakash; Pascopella, Lisa; Riley, Lee W; Reingold, Arthur L

    2005-10-01

    To summarize, using meta-analysis, the accuracy of bacteriophage-based assays for the detection of rifampicin resistance in Mycobacterium tuberculosis. By searching multiple databases and sources we identified a total of 21 studies eligible for meta-analysis. Of these, 14 studies used phage amplification assays (including eight studies on the commercial FASTPlaque-TB kits), and seven used luciferase reporter phage (LRP) assays. Sensitivity, specificity, and agreement between phage assay and reference standard (e.g. agar proportion method or BACTEC 460) results were the main outcomes of interest. When performed on culture isolates (N=19 studies), phage assays appear to have relatively high sensitivity and specificity. Eleven of 19 (58%) studies reported sensitivity and specificity estimates > or =95%, and 13 of 19 (68%) studies reported > or =95% agreement with reference standard results. Specificity estimates were slightly lower and more variable than sensitivity; 5 of 19 (26%) studies reported specificity <90%. Only two studies performed phage assays directly on sputum specimens; although one study reported sensitivity and specificity of 100 and 99%, respectively, another reported sensitivity of 86% and specificity of 73%. Current evidence is largely restricted to the use of phage assays for the detection of rifampicin resistance in culture isolates. When used on culture isolates, these assays appear to have high sensitivity, but variable and slightly lower specificity. In contrast, evidence is lacking on the accuracy of these assays when they are directly applied to sputum specimens. If phage-based assays can be directly used on clinical specimens and if they are shown to have high accuracy, they have the potential to improve the diagnosis of MDR-TB. However, before phage assays can be successfully used in routine practice, several concerns have to be addressed, including unexplained false positives in some studies, potential for contamination and indeterminate results.

  11. Diagnostic accuracy of 22/25-gauge core needle in endoscopic ultrasound-guided sampling: systematic review and meta-analysis.

    PubMed

    Oh, Hyoung-Chul; Kang, Hyun; Lee, Jae Young; Choi, Geun Joo; Choi, Jung Sik

    2016-11-01

    To compare the diagnostic accuracy of endoscopic ultrasound-guided core needle aspiration with that of standard fine-needle aspiration by systematic review and meta-analysis. Studies using 22/25-gauge core needles, irrespective of comparison with standard fine needles, were comprehensively reviewed. Pooled sensitivity, specificity, diagnostic odds ratio (DOR), and summary receiver operating characteristic curves for the diagnosis of malignancy were used to estimate the overall diagnostic efficiency. The pooled sensitivity, specificity, and DOR of the core needle for the diagnosis of malignancy were 0.88 (95% confidence interval [CI], 0.84 to 0.90), 0.99 (95% CI, 0.96 to 1), and 167.37 (95% CI, 65.77 to 425.91), respectively. The pooled sensitivity, specificity, and DOR of the standard needle were 0.84 (95% CI, 0.79 to 0.88), 1 (95% CI, 0.97 to 1), and 130.14 (95% CI, 34.00 to 495.35), respectively. The area under the curve of core and standard needle in the diagnosis of malignancy was 0.974 and 0.955, respectively. The core and standard needle were comparable in terms of pancreatic malignancy diagnosis. There was no significant difference in procurement of optimal histologic cores between core and standard needles (risk ratio [RR], 0.545; 95% CI, 0.187 to 1.589). The number of needle passes for diagnosis was significantly lower with the core needle (standardized mean difference, -0.72; 95% CI, -1.02 to -0.41). There were no significant differences in overall complications (RR, 1.26; 95% CI, 0.34 to 4.62) and technical failure (RR, 5.07; 95% CI, 0.68 to 37.64). Core and standard needles were comparable in terms of diagnostic accuracy, technical performance, and safety profile.

  12. Lipopolysaccharide Specific Immunochromatography Based Lateral Flow Assay for Serogroup Specific Diagnosis of Leptospirosis in India

    PubMed Central

    Vanithamani, Shanmugam; Shanmughapriya, Santhanam; Narayanan, Ramasamy; Raja, Veerapandian; Kanagavel, Murugesan; Sivasankari, Karikalacholan; Natarajaseenivasan, Kalimuthusamy

    2015-01-01

    Background Leptospirosis is a re-emerging infectious disease that is under-recognized due to low-sensitivity and cumbersome serological tests. MAT is the gold standard test and it is the only serogroup specific test used till date. Rapid reliable alternative serogroup specific tests are needed for surveillance studies to identify locally circulating serogroups in the study area. Methods/Principal Findings In the present investigation the serological specificity of leptospiral lipopolysaccharides (LPS) was evaluated by enzyme linked immunosorbent assay (ELISA), dot blot assay and rapid immunochromatography based lateral flow assay (ICG-LFA). Sera samples from 120 MAT positive cases, 174 cases with febrile illness other than leptospirosis, and 121 seronegative healthy controls were evaluated for the diagnostic sensitivity and specificity of the developed assays. LPS was extracted from five locally predominant circulating serogroups including: Australis (27.5%), Autumnalis (11.7%), Ballum (25.8%), Grippotyphosa (12.5%), Pomona (10%) and were used as antigens in the diagnostics to detect IgM antibodies in patients’ sera. The sensitivity observed by IgM ELISA and dot blot assay using various leptospiral LPS was >90% for homologous sera. Except for Ballum LPS, no other LPS showed cross-reactivity to heterologous sera. An attempt was made to develop LPS based ICG-LFA for rapid and sensitive serogroup specific diagnostics of leptospirosis. The developed ICG-LFA showed sensitivity in the range between 93 and 100% for homologous sera. The Wilcoxon analysis showed LPS based ICG-LFA did not differ significantly from the gold standard MAT (P>0.05). Conclusion The application of single array of LPS for serogroup specific diagnosis is first of its kind. The developed assay could potentially be evaluated and employed for as MAT alternative. PMID:26340095

  13. Acute Brain Imaging in Children: Can MRI Replace CT as a Screening Tool?

    PubMed

    Wagner, Matthias W; Kontzialis, Marinos; Seeburg, Daniel; Stern, Steven E; Oshmyansky, Alexander; Poretti, Andrea; Huisman, Thierry A G M

    2016-01-01

    To determine if axial T2-weighted imaging can serve as screening tool for pediatric brain imaging. We retrospectively evaluated consecutive brain magnetic resonance imaging (MRI) data of 161 children (74 girls) with a mean age of 7.44 ± 5.71 years. Standard of reference was the final report of neuroradiology attendings. Three readers with different levels of experience were blinded for clinical diagnoses and study indications. First, readers studied only the axial T2-weighted screening sequence. Second, they studied all available anatomical and functional MRI sequences as performed per standard protocol for each clinical indication. The readings were classified as normal or abnormal. Sensitivity and specificity were measured. Axial T2 screening yielded a sensitivity of 77-88% and a specificity of 92%. The full studies/data sets had a sensitivity of 89-95% and a specificity of 86-93%. Nineteen of 167 studies were acquired for acute and 148 of 167 studies for nonacute clinical indication. Twenty-five false-negative diagnoses paneled in three groups were made by all readers together. Readers misread four of 19 studies with acute and 21 of 148 studies with nonacute clinical indication. Four of 21 misread studies with nonacute indications harbored unexpected findings needing management. Axial T2 screening can detect pediatric brain abnormalities with high sensitivity and specificity and can possibly replace CT as screening tool if the reading physician is aware of possible limitations/pitfalls. The level of experience influences sensitivity and specificity. Adding diffusion-weighted imaging and susceptibility-weighted imaging to a 3-dimensional T2-weighted sequence would most likely further increase sensitivity and specificity. Copyright © 2015 by the American Society of Neuroimaging.

  14. Validation of different techniques for the diagnosis of ventilator-associated pneumonia. Comparison with immediate postmortem pulmonary biopsy.

    PubMed

    Torres, A; el-Ebiary, M; Padró, L; Gonzalez, J; de la Bellacasa, J P; Ramirez, J; Xaubet, A; Ferrer, M; Rodriguez-Roisin, R

    1994-02-01

    To assess the accuracy of clinical parameters for the diagnosis of ventilator-associated (VA) pneumonia, as well as the diagnostic value of several invasive techniques, such as protected specimen brush (PSB), bronchoalveolar lavage (BAL), fiberoptic bronchial aspirates (FBAS), and percutaneous lung needle aspiration (PLNA), we compared the results of these techniques with the histopathology of immediate postmortem pulmonary biopsies, considered the "gold standard" reference test. We studied 30 mechanically ventilated patients (age 52 +/- 21 yr; mechanical ventilation period 9 +/- 7 days) who died in an intensive care unit. All patients received prior antibiotic treatment. The following procedures were performed immediately after death: bilateral PSB, BAL, FBAS, and PLNA, as well as bilateral minithoracotomies to obtain pulmonary biopsies as close as possible to the area sampled with the other techniques. According to the histopathology 18 patients had pneumonia and 12 did not. The presence of fever (sensitivity 55%, specificity 58%), purulent secretions (sensitivity 83%, specificity 33%), and chest radiograph infiltrates (sensitivity 78%, specificity 42%) could not differentiate in all instances presence from absence of pneumonia. Quantitative bacterial cultures of lung biopsies using 10(3) cfu/g as a cutoff point had low sensitivity (40%) and low specificity (45%) and could not differentiate the histologic absence or presence of pneumonia. Considering the histopathology of pulmonary biopsies as a gold standard, we found the following sensitivities for PSB, BAL, FBAS, and PLNA: 36, 50, 44, and 25%. The specificities were 50, 45, 48, and 79%, respectively. The sensitivities and specificities of different invasive techniques are much lower than those reported in clinical studies.(ABSTRACT TRUNCATED AT 250 WORDS)

  15. Moderate sensitivity and high specificity of emergency department administrative data for transient ischemic attacks.

    PubMed

    Yu, Amy Y X; Quan, Hude; McRae, Andrew; Wagner, Gabrielle O; Hill, Michael D; Coutts, Shelagh B

    2017-09-18

    Validation of administrative data case definitions is key for accurate passive surveillance of disease. Transient ischemic attack (TIA) is a condition primarily managed in the emergency department. However, prior validation studies have focused on data after inpatient hospitalization. We aimed to determine the validity of the Canadian 10th International Classification of Diseases (ICD-10-CA) codes for TIA in the national ambulatory administrative database. We performed a diagnostic accuracy study of four ICD-10-CA case definition algorithms for TIA in the emergency department setting. The study population was obtained from two ongoing studies on the diagnosis of TIA and minor stroke versus stroke mimic using serum biomarkers and neuroimaging. Two reference standards were used 1) the emergency department clinical diagnosis determined by chart abstractors and 2) the 90-day final diagnosis, both obtained by stroke neurologists, to calculate the sensitivity, specificity, positive and negative predictive values (PPV and NPV) of the ICD-10-CA algorithms for TIA. Among 417 patients, emergency department adjudication showed 163 (39.1%) TIA, 155 (37.2%) ischemic strokes, and 99 (23.7%) stroke mimics. The most restrictive algorithm, defined as a TIA code in the main position had the lowest sensitivity (36.8%), but highest specificity (92.5%) and PPV (76.0%). The most inclusive algorithm, defined as a TIA code in any position with and without query prefix had the highest sensitivity (63.8%), but lowest specificity (81.5%) and PPV (68.9%). Sensitivity, specificity, PPV, and NPV were overall lower when using the 90-day diagnosis as reference standard. Emergency department administrative data reflect diagnosis of suspected TIA with high specificity, but underestimate the burden of disease. Future studies are necessary to understand the reasons for the low to moderate sensitivity.

  16. Detection of hepatitis B virus infection markers in dried plasma spots among patients in Congo-Brazzaville.

    PubMed

    Alidjinou, Enagnon Kazali; Moukassa, Donatien; Sané, Famara; Twagirimana Nyenyeli, Séraphin; Akoko, Estina Chandrelle; Mountou, Michèle Valy; Bocket, Laurence; Ibara, Jean-Rosaire; Hober, Didier

    2014-03-01

    The detection of hepatitis B virus (HBV) infection markers by using dried plasma spots from 32 patients living in Congo has been assessed. Considering frozen plasma samples as gold standard, the sensitivity and specificity of HBV serologic markers detection in dried plasma eluted from filter paper were 100%. The sensitivity and the specificity of HBV DNA detection reached 96% and 100%, respectively, with plasma samples dried on filter paper compared to standard samples. Dried plasma samples can represent an alternative to conventional sampling for HBV detection and management of the infection in developing countries. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Meta-analysis for the comparison of two diagnostic tests to a common gold standard: A generalized linear mixed model approach.

    PubMed

    Hoyer, Annika; Kuss, Oliver

    2018-05-01

    Meta-analysis of diagnostic studies is still a rapidly developing area of biostatistical research. Especially, there is an increasing interest in methods to compare different diagnostic tests to a common gold standard. Restricting to the case of two diagnostic tests, in these meta-analyses the parameters of interest are the differences of sensitivities and specificities (with their corresponding confidence intervals) between the two diagnostic tests while accounting for the various associations across single studies and between the two tests. We propose statistical models with a quadrivariate response (where sensitivity of test 1, specificity of test 1, sensitivity of test 2, and specificity of test 2 are the four responses) as a sensible approach to this task. Using a quadrivariate generalized linear mixed model naturally generalizes the common standard bivariate model of meta-analysis for a single diagnostic test. If information on several thresholds of the tests is available, the quadrivariate model can be further generalized to yield a comparison of full receiver operating characteristic (ROC) curves. We illustrate our model by an example where two screening methods for the diagnosis of type 2 diabetes are compared.

  18. Probabilistic brain tissue segmentation in neonatal magnetic resonance imaging.

    PubMed

    Anbeek, Petronella; Vincken, Koen L; Groenendaal, Floris; Koeman, Annemieke; van Osch, Matthias J P; van der Grond, Jeroen

    2008-02-01

    A fully automated method has been developed for segmentation of four different structures in the neonatal brain: white matter (WM), central gray matter (CEGM), cortical gray matter (COGM), and cerebrospinal fluid (CSF). The segmentation algorithm is based on information from T2-weighted (T2-w) and inversion recovery (IR) scans. The method uses a K nearest neighbor (KNN) classification technique with features derived from spatial information and voxel intensities. Probabilistic segmentations of each tissue type were generated. By applying thresholds on these probability maps, binary segmentations were obtained. These final segmentations were evaluated by comparison with a gold standard. The sensitivity, specificity, and Dice similarity index (SI) were calculated for quantitative validation of the results. High sensitivity and specificity with respect to the gold standard were reached: sensitivity >0.82 and specificity >0.9 for all tissue types. Tissue volumes were calculated from the binary and probabilistic segmentations. The probabilistic segmentation volumes of all tissue types accurately estimated the gold standard volumes. The KNN approach offers valuable ways for neonatal brain segmentation. The probabilistic outcomes provide a useful tool for accurate volume measurements. The described method is based on routine diagnostic magnetic resonance imaging (MRI) and is suitable for large population studies.

  19. Evaluation of Visual Field Progression in Glaucoma: Quasar Regression Program and Event Analysis.

    PubMed

    Díaz-Alemán, Valentín T; González-Hernández, Marta; Perera-Sanz, Daniel; Armas-Domínguez, Karintia

    2016-01-01

    To determine the sensitivity, specificity and agreement between the Quasar program, glaucoma progression analysis (GPA II) event analysis and expert opinion in the detection of glaucomatous progression. The Quasar program is based on linear regression analysis of both mean defect (MD) and pattern standard deviation (PSD). Each series of visual fields was evaluated by three methods; Quasar, GPA II and four experts. The sensitivity, specificity and agreement (kappa) for each method was calculated, using expert opinion as the reference standard. The study included 439 SITA Standard visual fields of 56 eyes of 42 patients, with a mean of 7.8 ± 0.8 visual fields per eye. When suspected cases of progression were considered stable, sensitivity and specificity of Quasar, GPA II and the experts were 86.6% and 70.7%, 26.6% and 95.1%, and 86.6% and 92.6% respectively. When suspected cases of progression were considered as progressing, sensitivity and specificity of Quasar, GPA II and the experts were 79.1% and 81.2%, 45.8% and 90.6%, and 85.4% and 90.6% respectively. The agreement between Quasar and GPA II when suspected cases were considered stable or progressing was 0.03 and 0.28 respectively. The degree of agreement between Quasar and the experts when suspected cases were considered stable or progressing was 0.472 and 0.507. The degree of agreement between GPA II and the experts when suspected cases were considered stable or progressing was 0.262 and 0.342. The combination of MD and PSD regression analysis in the Quasar program showed better agreement with the experts and higher sensitivity than GPA II.

  20. Detection of Echinococcus multilocularis by MC-PCR: evaluation of diagnostic sensitivity and specificity without gold standard

    PubMed Central

    Wahlström, Helene; Comin, Arianna; Isaksson, Mats; Deplazes, Peter

    2016-01-01

    Introduction A semi-automated magnetic capture probe-based DNA extraction and real-time PCR method (MC-PCR), allowing for a more efficient large-scale surveillance of Echinococcus multilocularis occurrence, has been developed. The test sensitivity has previously been evaluated using the sedimentation and counting technique (SCT) as a gold standard. However, as the sensitivity of the SCT is not 1, test characteristics of the MC-PCR was also evaluated using latent class analysis, a methodology not requiring a gold standard. Materials and methods Test results, MC-PCR and SCT, from a previous evaluation of the MC-PCR using 177 foxes shot in the spring (n=108) and autumn 2012 (n=69) in high prevalence areas in Switzerland were used. Latent class analysis was used to estimate the test characteristics of the MC-PCR. Although it is not the primary aim of this study, estimates of the test characteristics of the SCT were also obtained. Results and discussion This study showed that the sensitivity of the MC-PCR was 0.88 [95% posterior credible interval (PCI) 0.80–0.93], which was not significantly different than the SCT, 0.83 (95% PCI 0.76–0.88), which is currently considered as the gold standard. The specificity of both tests was high, 0.98 (95% PCI 0.94–0.99) for the MC-PCR and 0.99 (95% PCI 0.99–1) for the SCT. In a previous study, using fox scats from a low prevalence area, the specificity of the MC-PCR was higher, 0.999% (95% PCI 0.997–1). One reason for the lower estimate of the specificity in this study could be that the MC-PCR detects DNA from infected but non-infectious rodents eaten by foxes. When using MC-PCR in low prevalence areas or areas free from the parasite, a positive result in the MC-PCR should be regarded as a true positive. Conclusion The sensitivity of the MC-PCR (0.88) was comparable to the sensitivity of SCT (0.83). PMID:26968153

  1. Rotator cuff crepitus: could Codman really feel a cuff tear?

    PubMed

    Ponce, Brent A; Kundukulam, Joseph A; Sheppard, Evan D; Determann, Jason R; McGwin, Gerald; Narducci, Carl A; Crowther, Marshall J

    2014-07-01

    The objective of this study was to assess the accuracy of palpating crepitus to diagnose rotator cuff tears. Seventy consecutive consenting patients who presented with shoulder pain and no previous imaging or surgery on the affected shoulder were prospectively enrolled during a 10-month period. A standardized patient history and examination, including the crepitus test, were recorded in addition to obtaining standard radiographs. Additional imaging after initial evaluation was performed with magnetic resonance imaging and interpreted by a musculoskeletal radiologist blinded to the examination findings. Statistical analysis was used to determine sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the crepitus test in the clinical diagnosis of a rotator cuff tear. Sixty-three patients had histories, examinations, and imaging studies available for analysis. The crepitus test had a sensitivity of 67%, specificity of 80%, PPV of 91%, and NPV of 43% for all types of rotator cuff tears. The sensitivity and specificity for full-thickness or high-grade partial tears was 82% and 73%, respectively; the PPV and NPV were 77% and 79%. Increasing age improved accuracy as the presence of crepitus in patients older than 55 years had a sensitivity of 76%, specificity of 100%, PPV of 100%, and NPV of 38%. The crepitus test has a favorable sensitivity, specificity, PPV, and NPV to assess the integrity of the rotator cuff and may be a useful examination in the clinical diagnosis of a rotator cuff tear. Published by Mosby, Inc.

  2. Optimizing the interpretation of CT for appendicitis: modeling health utilities for clinical practice.

    PubMed

    Blackmore, C Craig; Terasawa, Teruhiko

    2006-02-01

    Error in radiology can be reduced by standardizing the interpretation of imaging studies to the optimum sensitivity and specificity. In this report, the authors demonstrate how the optimal interpretation of appendiceal computed tomography (CT) can be determined and how it varies in different clinical scenarios. Utility analysis and receiver operating characteristic (ROC) curve modeling were used to determine the trade-off between false-positive and false-negative test results to determine the optimal operating point on the ROC curve for the interpretation of appendicitis CT. Modeling was based on a previous meta-analysis for the accuracy of CT and on literature estimates of the utilities of various health states. The posttest probability of appendicitis was derived using Bayes's theorem. At a low prevalence of disease (screening), appendicitis CT should be interpreted at high specificity (97.7%), even at the expense of lower sensitivity (75%). Conversely, at a high probability of disease, high sensitivity (97.4%) is preferred (specificity 77.8%). When the clinical diagnosis of appendicitis is equivocal, CT interpretation should emphasize both sensitivity and specificity (sensitivity 92.3%, specificity 91.5%). Radiologists can potentially decrease medical error and improve patient health by varying the interpretation of appendiceal CT on the basis of the clinical probability of appendicitis. This report is an example of how utility analysis can be used to guide radiologists in the interpretation of imaging studies and provide guidance on appropriate targets for the standardization of interpretation.

  3. Sensitivity and Specificity of OCT Angiography to Detect Choroidal Neovascularization.

    PubMed

    Faridi, Ambar; Jia, Yali; Gao, Simon S; Huang, David; Bhavsar, Kavita V; Wilson, David J; Sill, Andrew; Flaxel, Christina J; Hwang, Thomas S; Lauer, Andreas K; Bailey, Steven T

    2017-01-01

    To determine the sensitivity and specificity of optical coherence tomography angiography (OCTA) in the detection of choroidal neovascularization (CNV) in age-related macular degeneration (AMD). Prospective case series. Prospective series of seventy-two eyes were studied, which included eyes with treatment-naive CNV due to AMD, non-neovascular AMD, and normal controls. All eyes underwent OCTA with a spectral domain (SD) OCT (Optovue, Inc.). The 3D angiogram was segmented into separate en face views including the inner retinal angiogram, outer retinal angiogram, and choriocapillaris angiogram. Detection of abnormal flow in the outer retina served as candidate CNV with OCTA. Masked graders reviewed structural OCT alone, en face OCTA alone, and en face OCTA combined with cross-sectional OCTA for the presence of CNV. The sensitivity and specificity of CNV detection compared to the gold standard of fluorescein angiography (FA) and OCT was determined for structural SD-OCT alone, en face OCTA alone, and with en face OCTA combined with cross-sectional OCTA. Of 32 eyes with CNV, both graders identified 26 true positives with en face OCTA alone, resulting in a sensitivity of 81.3%. Four of the 6 false negatives had large subretinal hemorrhage (SRH) and sensitivity improved to 94% for both graders if eyes with SRH were excluded. The addition of cross-sectional OCTA along with en face OCTA improved the sensitivity to 100% for both graders. Structural OCT alone also had a sensitivity of 100%. The specificity of en face OCTA alone was 92.5% for grader A and 97.5% for grader B. The specificity of structural OCT alone was 97.5% for grader A and 85% for grader B. Cross-sectional OCTA combined with en face OCTA had a specificity of 97.5% for grader A and 100% for grader B. Sensitivity and specificity for CNV detection with en face OCTA combined with cross-sectional OCTA approaches that of the gold standard of FA with OCT, and it is better than en face OCTA alone. Structural OCT alone has excellent sensitivity for CNV detection. False positives from structural OCT can be mitigated with the addition of flow information with OCTA.

  4. Diagnosis of deep endometriosis: clinical examination, ultrasonography, magnetic resonance imaging, and other techniques.

    PubMed

    Bazot, Marc; Daraï, Emile

    2017-12-01

    The aim of the present review was to evaluate the contribution of clinical examination and imaging techniques, mainly transvaginal sonography and magnetic resonance imaging (MRI) to diagnose deep infiltrating (DE) locations using prisma statement recommendations. Clinical examination has a relative low sensitivity and specificity to diagnose DE. Independently of DE locations, for all transvaginal sonography techniques a pooled sensitivity and specificity of 79% and 94% are observed approaching criteria for a triage test. Whatever the protocol and MRI devices, the pooled sensitivity and specificity for pelvic endometriosis diagnosis were 94% and 77%, respectively. For rectosigmoid endometriosis, pooled sensitivity and specificity of MRI were 92% and 96%, respectively fulfilling criteria of replacement test. In conclusion, advances in imaging techniques offer high sensitivity and specificity to diagnose DE with at least triage value and for rectosigmoid endometriosis replacement value imposing a revision of the concept of laparoscopy as the gold standard. Copyright © 2017 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  5. Self-diagnosis of active head lice infestation by individuals from an impoverished community: high sensitivity and specificity.

    PubMed

    Pilger, Daniel; Khakban, Adak; Heukelbach, Jorg; Feldmeier, Hermann

    2008-01-01

    To compare sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of self-diagnosis for head lice infestation with visual inspection, we conducted a study in an urban slum in Brazil. Individuals were asked about active head lice infestation (self-diagnosis); we performed visual inspection and thereafter wet combing (gold standard). Of the 175 individuals included, 77 (44%) had an active head lice infestation. For self-diagnosis, sensitivity (80.5%), specificity (91.8%), PPV (88.6%) and NPV (85.7%) were high. Sensitivity of visual inspection was 35.1%. Public health professionals can use self-diagnosis as a diagnostic tool, to estimate accurately prevalence of pediculosis in a community, and to monitor ongoing intervention strategies.

  6. Predictive Accuracy of Sweep Frequency Impedance Technology in Identifying Conductive Conditions in Newborns.

    PubMed

    Aithal, Venkatesh; Kei, Joseph; Driscoll, Carlie; Murakoshi, Michio; Wada, Hiroshi

    2018-02-01

    Diagnosing conductive conditions in newborns is challenging for both audiologists and otolaryngologists. Although high-frequency tympanometry (HFT), acoustic stapedial reflex tests, and wideband absorbance measures are useful diagnostic tools, there is performance measure variability in their detection of middle ear conditions. Additional diagnostic sensitivity and specificity measures gained through new technology such as sweep frequency impedance (SFI) measures may assist in the diagnosis of middle ear dysfunction in newborns. The purpose of this study was to determine the test performance of SFI to predict the status of the outer and middle ear in newborns against commonly used reference standards. Automated auditory brainstem response (AABR), HFT (1000 Hz), transient evoked otoacoustic emission (TEOAE), distortion product otoacoustic emission (DPOAE), and SFI tests were administered to the study sample. A total of 188 neonates (98 males and 90 females) with a mean gestational age of 39.4 weeks were included in the sample. Mean age at the time of testing was 44.4 hr. Diagnostic accuracy of SFI was assessed in terms of its ability to identify conductive conditions in neonates when compared with nine different reference standards (including four single tests [AABR, HFT, TEOAE, and DPOAE] and five test batteries [HFT + DPOAE, HFT + TEOAE, DPOAE + TEOAE, DPOAE + AABR, and TEOAE + AABR]), using receiver operating characteristic (ROC) analysis and traditional test performance measures such as sensitivity and specificity. The test performance of SFI against the test battery reference standard of HFT + DPOAE and single reference standard of HFT was high with an area under the ROC curve (AROC) of 0.87 and 0.82, respectively. Although the HFT + DPOAE test battery reference standard performed better than the HFT reference standard in predicting middle ear conductive conditions in neonates, the difference in AROC was not significant. Further analysis revealed that the highest sensitivity and specificity for SFI (86% and 88%, respectively) was obtained when compared with the reference standard of HFT + DPOAE. Among the four single reference standards, SFI had the highest sensitivity and specificity (76% and 88%, respectively) when compared against the HFT reference standard. The high test performance of SFI against the HFT and HFT + DPOAE reference standards indicates that the SFI measure has appropriate diagnostic accuracy in detection of conductive conditions in newborns. Hence, the SFI test could be used as adjunct tool to identify conductive conditions in universal newborn hearing screening programs, and can also be used in diagnostic follow-up assessments. American Academy of Audiology

  7. [Diagnostic strategies in the Tuberculosis Clinic of the Hospital General La Raza National Medical Center].

    PubMed

    Flores-Ibarra, Alberto Alejandro; Ochoa-Vázquez, María Dolores; Sánchez-Tec, Georgina Alejandra

    2016-01-01

    In order to diagnose TB infection, tuberculin skin test and interferon gamma release assay are available. The tuberculin test has a sensitivity of 99 % and a specificity of 95 %. For the detection of interferon gamma in blood there are currently two tests available: TBGold QuantiFERON-In-Tube (with a sensitivity of 0.70 and a specificity of 0.90), and T-SPOT-TB (sensitivity 0.90 and specificity 0.93). To diagnose the disease, a microscopy of direct smears for acid-fast bacilli is used if the physician is facing an extensive cavitary lung disease due to M. tuberculosis (this test has a high sensitivity: 80-90 %). The most common staining techniques used are Ziehl-Neelsen and Kinyoun, and the fluorescent technique, auramine-rhodamine. The culture is the gold standard and it has a sensitivity of 80 % and a specificity over 90 %, but the results take weeks. The nucleic acid amplification test has an overall sensitivity and specificity of 0.85 and 0.97, respectively. In the presence of a pleural effusion is necessary to perform a pleural biopsy for culture with a sensitivity of 85 % if it is percutaneous and 98 % if it was taken by thoracoscopy. The adenosine deaminase can be determined in pleural fluid with a sensitivity and specificity of 95 %.

  8. Total and free cortisol levels during 1 μg, 25 μg, and 250 μg cosyntropin stimulation tests compared to insulin tolerance test: results of a randomized, prospective, pilot study.

    PubMed

    Peechakara, Seenia; Bena, James; Clarke, Nigel J; McPhaul, Michael J; Reitz, Richard E; Weil, Robert J; Recinos, Pablo; Kennedy, Laurence; Hamrahian, Amir H

    2017-09-01

    The appropriate cosyntropin dose during cosyntropin stimulation tests remains uncertain. We conducted a prospective, randomized pilot study to compare 1 μg IV low dose cosyntropin test, 25 μg IM medium dose cosyntropin test, and 250 μg IM standard dose cosyntropin test to evaluate secondary adrenal insufficiency. Insulin tolerance test was used as the gold standard. The study included patients with hypothalamic/pituitary disease (n  = 10) with at least one pituitary axis deficiency other than ACTH deficiency and controls (n  = 12). All tests were done in random order. Sensitivity and specificity were calculated for total cortisol and serum free cortisol cut-off levels during cosyntropin stimulation tests. The median (range) age and F/M sex ratios for patients and controls were 54 years (23-62), 2/8, and 33 years (21-51), 6/6, respectively. The best total cortisol cut-off during low dose cosyntropin test, medium dose cosyntropin test, 30 min and 60 min standard dose cosyntropin test were 14.6 μg/dL (100% sensitivity & specificity), 18.7 μg/dL (100% sensitivity, 88% specificity), 16.1 (100% sensitivity & specificity), and 19.5 μg/dL (100% sensitivity & specificity), respectively. There was no difference in the ROC curve for cortisol values between the cosyntropin stimulation tests (p  > 0.41). Using a cortisol cut-off of 18 μg/dL during cosyntropin stimulation tests, only cortisol level at 30 min during standard dose cosyntropin test provided discrimination similar to insulin tolerance test. The best peak free cortisol cut-off levels were 1 μg/dL for insulin tolerance test, 0.9 μg/dL for low dose cosyntropin test, 0.9 μg/dL for medium dose cosyntropin test, and 0.9 μg/dL and 1.3 μg/dL for 30 min and 60 min standard dose cosyntropin test, respectively. All cosyntropin stimulation tests had excellent correlations with insulin tolerance test, when appropriate cut-offs were used. This pilot study does not suggest an advantage in using 25 μg cosyntropin dose during the cosyntropin stimulation test. A serum free cortisol cut-off of 0.9 μg/dL may be used as pass criterion during low dose cosyntropin test, standard dose cosyntropin test cosyntropin test, and 30 min standard dose cosyntropin test.

  9. Measuring Coverage in MNCH: Accuracy of Measuring Diagnosis and Treatment of Childhood Malaria from Household Surveys in Zambia

    PubMed Central

    Eisele, Thomas P.; Silumbe, Kafula; Yukich, Josh; Hamainza, Busiku; Keating, Joseph; Bennett, Adam; Miller, John M.

    2013-01-01

    Background To assess progress in the scale-up of rapid diagnostic tests and artemisinin-based combination therapies (ACTs) across Africa, malaria control programs have increasingly relied on standardized national household surveys to determine the proportion of children with a fever in the past 2 wk who received an effective antimalarial within 1–2 d of the onset of fever. Here, the validity of caregiver recall for measuring the primary coverage indicators for malaria diagnosis and treatment of children <5 y old is assessed. Methods and Findings A cross-sectional study was conducted in five public clinics in Kaoma District, Western Provence, Zambia, to estimate the sensitivity, specificity, and accuracy of caregivers' recall of malaria testing, diagnosis, and treatment, compared to a gold standard of direct observation at the health clinics. Compared to the gold standard of clinic observation, for recall for children with fever in the past 2 wk, the sensitivity for recalling that a finger/heel stick was done was 61.9%, with a specificity of 90.0%. The sensitivity and specificity of caregivers' recalling a positive malaria test result were 62.4% and 90.7%, respectively. The sensitivity and specificity of recalling that the child was given a malaria diagnosis, irrespective of whether a laboratory test was actually done, were 76.8% and 75.9%, respectively. The sensitivity and specificity for recalling that an ACT was given were 81.0% and 91.5%, respectively. Conclusions Based on these findings, results from household surveys should continue to be used for ascertaining the coverage of children with a fever in the past 2 wk that received an ACT. However, as recall of a malaria diagnosis remains suboptimal, its use in defining malaria treatment coverage is not recommended. Please see later in the article for the Editors' Summary PMID:23667337

  10. Evaluation of clinical methods for diagnosing bacterial vaginosis.

    PubMed

    Gutman, Robert E; Peipert, Jeffrey F; Weitzen, Sherry; Blume, Jeffrey

    2005-03-01

    To determine whether the current clinical criteria for diagnosing bacterial vaginosis can be simplified by using 2 clinical criteria rather than the standard 3 of 4 criteria (Amsel's criteria). This was a prospective observational study of 269 women undergoing a vaginal examination in the Women's Primary Care Center, Division of Research, or Colposcopy Clinic at Women & Infants Hospital. All 4 clinical criteria for diagnosing bacterial vaginosis were collected, and Gram stain was used as the gold standard. Sensitivity and specificity were calculated for each individual criterion, combinations of criteria, and a colorimetric pH and amine card. Receiver operating characteristic curve was generated to estimate the preferred pH and percentage of clue cells for diagnosing bacterial vaginosis. The prevalence of bacterial vaginosis in our study population was 38.7%. Vaginal pH was the most sensitive of all the criteria, at 89%, and a positive amine odor was the individual criteria with the highest specificity, at 93%. Similar specificity was seen with combinations of 2 criteria and Amsel's criteria. Receiver operating characteristic curve analysis yielded a preferred pH and percentage of clue cells of 5.0 and 20%, respectively. However, a pH of 4.5 or greater improves sensitivity with minimal loss of specificity. The clinical criteria for diagnosing bacterial vaginosis can be simplified to 2 clinical criteria without loss of sensitivity and specificity.

  11. How typical are 'typical' tremor characteristics? Sensitivity and specificity of five tremor phenomena.

    PubMed

    van der Stouwe, A M M; Elting, J W; van der Hoeven, J H; van Laar, T; Leenders, K L; Maurits, N M; Tijssen, M A J

    2016-09-01

    Distinguishing between different tremor disorders can be challenging. Some tremor disorders are thought to have typical tremor characteristics: the current study aims to provide sensitivity and specificity for five 'typical' tremor phenomena. Retrospectively, we examined 210 tremor patients referred for electrophysiological recordings between January 2008 and January 2014. The final clinical diagnosis was used as the gold standard. The first step was to determine whether patients met neurophysiological criteria for their type of tremor. Once established, we focused on 'typical' characteristics: tremor frequency decrease upon loading (enhanced physiological tremor (EPT)), amplitude increase upon loading, distractibility and entrainment (functional tremor (FT)), and intention tremor (essential tremor (ET)). The prevalence of these phenomena in the 'typical' group was compared to the whole group. Most patients (87%) concurred with all core clinical neurophysiological criteria for their tremor type. We found a frequency decrease upon loading to be a specific (95%), but not a sensitive (42%) test for EPT. Distractibility and entrainment both scored high on sensitivity (92%, 91%) and specificity (94%, 91%) in FT, whereas a tremor amplitude increase was specific (92%), but not sensitive (22%). Intention tremor was a specific finding in ET (85%), but not a sensitive test (45%). Combination of characteristics improved sensitivity. In this study, we retrospectively determined sensitivity and specificity for five 'typical' tremor characteristics. Characteristics proved specific, but few were sensitive. These data on tremor phenomenology will help practicing neurologists to improve distinction between different tremor disorders. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. High-definition vs. standard-definition colonoscopy in the characterization of small colonic polyps: results from a randomized trial.

    PubMed

    Longcroft-Wheaton, G; Brown, J; Cowlishaw, D; Higgins, B; Bhandari, P

    2012-10-01

    The resolution of endoscopes has increased in recent years. Modern Fujinon colonoscopes have a charge-coupled device (CCD) pixel density of 650,000 pixels compared with the 410,000 pixel CCD in standard-definition scopes. Acquiring high-definition scopes represents a significant capital investment and their clinical value remains uncertain. The aim of the current study was to investigate the impact of high-definition endoscopes on the in vivo histology prediction of colonic polyps. Colonoscopy procedures were performed using Fujinon colonoscopes and EPX-4400 processor. Procedures were randomized to be performed using either a standard-definition EC-530 colonoscope or high-definition EC-530 and EC-590 colonoscopes. Polyps of <10 mm were assessed using both white light imaging (WLI) and flexible spectral imaging color enhancement (FICE), and the predicted diagnosis was recorded. Polyps were removed and sent for histological analysis by a pathologist who was blinded to the endoscopic diagnosis. The predicted diagnosis was compared with the histology to calculate the accuracy, sensitivity, and specificity of in vivo assessment using either standard or high-definition scopes. A total of 293 polyps of <10 mm were examined–150 polyps using the standard-definition colonoscope and 143 polyps using high-definition colonoscopes. There was no difference in sensitivity, specificity or accuracy between the two scopes when WLI was used (standard vs. high: accuracy 70% [95% CI 62–77] vs. 73% [95% CI 65–80]; P=0.61). When FICE was used, high-definition colonoscopes showed a sensitivity of 93% compared with 83% for standard-definition colonoscopes (P=0.048); specificity was 81% and 82%, respectively. There was no difference between high- and standard-definition colonoscopes when white light was used, but FICE significantly improved the in vivo diagnosis of small polyps when high-definition scopes were used compared with standard definition.

  13. LH750 hematology analyzers to identify malaria and dengue and distinguish them from other febrile illnesses.

    PubMed

    Sharma, P; Bhargava, M; Sukhachev, D; Datta, S; Wattal, C

    2014-02-01

    Tropical febrile illnesses such as malaria and dengue are challenging to differentiate clinically. Automated cellular indices from hematology analyzers may afford a preliminary rapid distinction. Blood count and VCS parameters from 114 malaria patients, 105 dengue patients, and 105 febrile controls without dengue or malaria were analyzed. Statistical discriminant functions were generated, and their diagnostic performances were assessed by ROC curve analysis. Three statistical functions were generated: (i) malaria-vs.-controls factor incorporating platelet count and standard deviations of lymphocyte volume and conductivity that identified malaria with 90.4% sensitivity, 88.6% specificity; (ii) dengue-vs.-controls factor incorporating platelet count, lymphocyte percentage and standard deviation of lymphocyte conductivity that identified dengue with 81.0% sensitivity and 77.1% specificity; and (iii) febrile-controls-vs.-malaria/dengue factor incorporating mean corpuscular hemoglobin concentration, neutrophil percentage, mean lymphocyte and monocyte volumes, and standard deviation of monocyte volume that distinguished malaria and dengue from other febrile illnesses with 85.1% sensitivity and 91.4% specificity. Leukocyte abnormalities quantitated by automated analyzers successfully identified malaria and dengue and distinguished them from other fevers. These economic discriminant functions can be rapidly calculated by analyzer software programs to generate electronic flags to trigger-specific testing. They could potentially transform diagnostic approaches to tropical febrile illnesses in cost-constrained settings. © 2013 John Wiley & Sons Ltd.

  14. Sensitivity, Specificity, and Predictive Values: Foundations, Pliabilities, and Pitfalls in Research and Practice.

    PubMed

    Trevethan, Robert

    2017-01-01

    Within the context of screening tests, it is important to avoid misconceptions about sensitivity, specificity, and predictive values. In this article, therefore, foundations are first established concerning these metrics along with the first of several aspects of pliability that should be recognized in relation to those metrics. Clarification is then provided about the definitions of sensitivity, specificity, and predictive values and why researchers and clinicians can misunderstand and misrepresent them. Arguments are made that sensitivity and specificity should usually be applied only in the context of describing a screening test's attributes relative to a reference standard; that predictive values are more appropriate and informative in actual screening contexts, but that sensitivity and specificity can be used for screening decisions about individual people if they are extremely high; that predictive values need not always be high and might be used to advantage by adjusting the sensitivity and specificity of screening tests; that, in screening contexts, researchers should provide information about all four metrics and how they were derived; and that, where necessary, consumers of health research should have the skills to interpret those metrics effectively for maximum benefit to clients and the healthcare system.

  15. SENSITIVITY AND SPECIFICITY OF DETECTING POLYPOIDAL CHOROIDAL VASCULOPATHY WITH EN FACE OPTICAL COHERENCE TOMOGRAPHY AND OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY.

    PubMed

    de Carlo, Talisa E; Kokame, Gregg T; Kaneko, Kyle N; Lian, Rebecca; Lai, James C; Wee, Raymond

    2018-03-20

    Determine sensitivity and specificity of polypoidal choroidal vasculopathy (PCV) diagnosis with structural en face optical coherence tomography (OCT) and OCT angiography (OCTA). Retrospective review of the medical records of eyes diagnosed with PCV by indocyanine green angiography with review of diagnostic testing with structural en face OCT and OCTA by a trained reader. Structural en face OCT, cross-sectional OCT angiograms alone, and OCTA in its entirety were reviewed blinded to the findings of indocyanine green angiography and each other to determine if they could demonstrate the PCV complex. Sensitivity and specificity of PCV diagnosis was determined for each imaging technique using indocyanine green angiography as the ground truth. Sensitivity and specificity of structural en face OCT were 30.0% and 85.7%, of OCT angiograms alone were 26.8% and 96.8%, and of the entire OCTA were 43.9% and 87.1%, respectively. Sensitivity and specificity were improved for OCT angiograms and OCTA when looking at images taken within 1 month of PCV diagnosis. Sensitivity of detecting PCV was low using structural en face OCT and OCTA but specificity was high. Indocyanine green angiography remains the gold standard for PCV detection.

  16. Sensitivity, Specificity, and Predictive Values: Foundations, Pliabilities, and Pitfalls in Research and Practice

    PubMed Central

    Trevethan, Robert

    2017-01-01

    Within the context of screening tests, it is important to avoid misconceptions about sensitivity, specificity, and predictive values. In this article, therefore, foundations are first established concerning these metrics along with the first of several aspects of pliability that should be recognized in relation to those metrics. Clarification is then provided about the definitions of sensitivity, specificity, and predictive values and why researchers and clinicians can misunderstand and misrepresent them. Arguments are made that sensitivity and specificity should usually be applied only in the context of describing a screening test’s attributes relative to a reference standard; that predictive values are more appropriate and informative in actual screening contexts, but that sensitivity and specificity can be used for screening decisions about individual people if they are extremely high; that predictive values need not always be high and might be used to advantage by adjusting the sensitivity and specificity of screening tests; that, in screening contexts, researchers should provide information about all four metrics and how they were derived; and that, where necessary, consumers of health research should have the skills to interpret those metrics effectively for maximum benefit to clients and the healthcare system. PMID:29209603

  17. A standardized model for predicting flap failure using indocyanine green dye

    NASA Astrophysics Data System (ADS)

    Zimmermann, Terence M.; Moore, Lindsay S.; Warram, Jason M.; Greene, Benjamin J.; Nakhmani, Arie; Korb, Melissa L.; Rosenthal, Eben L.

    2016-03-01

    Techniques that provide a non-invasive method for evaluation of intraoperative skin flap perfusion are currently available but underutilized. We hypothesize that intraoperative vascular imaging can be used to reliably assess skin flap perfusion and elucidate areas of future necrosis by means of a standardized critical perfusion threshold. Five animal groups (negative controls, n=4; positive controls, n=5; chemotherapy group, n=5; radiation group, n=5; chemoradiation group, n=5) underwent pre-flap treatments two weeks prior to undergoing random pattern dorsal fasciocutaneous flaps with a length to width ratio of 2:1 (3 x 1.5 cm). Flap perfusion was assessed via laser-assisted indocyanine green dye angiography and compared to standard clinical assessment for predictive accuracy of flap necrosis. For estimating flap-failure, clinical prediction achieved a sensitivity of 79.3% and a specificity of 90.5%. When average flap perfusion was more than three standard deviations below the average flap perfusion for the negative control group at the time of the flap procedure (144.3+/-17.05 absolute perfusion units), laser-assisted indocyanine green dye angiography achieved a sensitivity of 81.1% and a specificity of 97.3%. When absolute perfusion units were seven standard deviations below the average flap perfusion for the negative control group, specificity of necrosis prediction was 100%. Quantitative absolute perfusion units can improve specificity for intraoperative prediction of viable tissue. Using this strategy, a positive predictive threshold of flap failure can be standardized for clinical use.

  18. Simple, Sensitive and Accurate Multiplex Detection of Clinically Important Melanoma DNA Mutations in Circulating Tumour DNA with SERS Nanotags

    PubMed Central

    Wee, Eugene J.H.; Wang, Yuling; Tsao, Simon Chang-Hao; Trau, Matt

    2016-01-01

    Sensitive and accurate identification of specific DNA mutations can influence clinical decisions. However accurate diagnosis from limiting samples such as circulating tumour DNA (ctDNA) is challenging. Current approaches based on fluorescence such as quantitative PCR (qPCR) and more recently, droplet digital PCR (ddPCR) have limitations in multiplex detection, sensitivity and the need for expensive specialized equipment. Herein we describe an assay capitalizing on the multiplexing and sensitivity benefits of surface-enhanced Raman spectroscopy (SERS) with the simplicity of standard PCR to address the limitations of current approaches. This proof-of-concept method could reproducibly detect as few as 0.1% (10 copies, CV < 9%) of target sequences thus demonstrating the high sensitivity of the method. The method was then applied to specifically detect three important melanoma mutations in multiplex. Finally, the PCR/SERS assay was used to genotype cell lines and ctDNA from serum samples where results subsequently validated with ddPCR. With ddPCR-like sensitivity and accuracy yet at the convenience of standard PCR, we believe this multiplex PCR/SERS method could find wide applications in both diagnostics and research. PMID:27446486

  19. Simple, Sensitive and Accurate Multiplex Detection of Clinically Important Melanoma DNA Mutations in Circulating Tumour DNA with SERS Nanotags.

    PubMed

    Wee, Eugene J H; Wang, Yuling; Tsao, Simon Chang-Hao; Trau, Matt

    2016-01-01

    Sensitive and accurate identification of specific DNA mutations can influence clinical decisions. However accurate diagnosis from limiting samples such as circulating tumour DNA (ctDNA) is challenging. Current approaches based on fluorescence such as quantitative PCR (qPCR) and more recently, droplet digital PCR (ddPCR) have limitations in multiplex detection, sensitivity and the need for expensive specialized equipment. Herein we describe an assay capitalizing on the multiplexing and sensitivity benefits of surface-enhanced Raman spectroscopy (SERS) with the simplicity of standard PCR to address the limitations of current approaches. This proof-of-concept method could reproducibly detect as few as 0.1% (10 copies, CV < 9%) of target sequences thus demonstrating the high sensitivity of the method. The method was then applied to specifically detect three important melanoma mutations in multiplex. Finally, the PCR/SERS assay was used to genotype cell lines and ctDNA from serum samples where results subsequently validated with ddPCR. With ddPCR-like sensitivity and accuracy yet at the convenience of standard PCR, we believe this multiplex PCR/SERS method could find wide applications in both diagnostics and research.

  20. Diagnostic accuracy of tests to detect Hepatitis C antibody: a meta-analysis and review of the literature.

    PubMed

    Tang, Weiming; Chen, Wen; Amini, Ali; Boeras, Debi; Falconer, Jane; Kelly, Helen; Peeling, Rosanna; Varsaneux, Olivia; Tucker, Joseph D; Easterbrook, Philippa

    2017-11-01

    Although direct-acting antivirals can achieve sustained virological response rates greater than 90% in Hepatitis C Virus (HCV) infected persons, at present the majority of HCV-infected individuals remain undiagnosed and therefore untreated. While there are a wide range of HCV serological tests available, there is a lack of formal assessment of their diagnostic performance. We undertook a systematic review and meta-analysis to evaluate he diagnostic accuracy of available rapid diagnostic tests (RDT) and laboratory based EIA assays in detecting antibodies to HCV. We used the PRISMA checklist and Cochrane guidance to develop our search protocol. The search strategy was registered in PROSPERO (CRD42015023567). The search focused on hepatitis C, diagnostic tests, and diagnostic accuracy within eight databases (MEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials, Science Citation Index Expanded, Conference Proceedings Citation Index-Science, SCOPUS, Literatura Latino-Americana e do Caribe em Ciências da Saúde and WHO Global Index Medicus. Studies were included if they evaluated an assay to determine the sensitivity and specificity of HCV antibody (HCV Ab) in humans. Two reviewers independently extracted data and performed a quality assessment of the studies using the QUADAS tool. We pooled test estimates using the DerSimonian-Laird method, by using the software R and RevMan. 5.3. A total of 52 studies were identified that included 52,673 unique test measurements. Based on five studies, the pooled sensitivity and specificity of HCV Ab rapid diagnostic tests (RDTs) were 98% (95% CI 98-100%) and 100% (95% CI 100-100%) compared to an enzyme immunoassay (EIA) reference standard. High HCV Ab RDTs sensitivity and specificity were observed across screening populations (general population, high risk populations, and hospital patients) using different reference standards (EIA, nucleic acid testing, immunoblot). There were insufficient studies to undertake subanalyses based on HIV co-infection. Oral HCV Ab RDTs also had excellent sensitivity and specificity compared to blood reference tests, respectively at 94% (95% CI 93-96%) and 100% (95% CI 100-100%). Among studies that assessed individual oral RDTs, the eight studies revealed that OraQuick ADVANCE® had a slightly higher sensitivity (98%, 95% CI 97-98%) compared to the other oral brands (pooled sensitivity: 88%, 95% CI 84-92%). RDTs, including oral tests, have excellent sensitivity and specificity compared to laboratory-based methods for HCV antibody detection across a wide range of settings. Oral HCV Ab RDTs had good sensitivity and specificity compared to blood reference standards.

  1. Diagnosis of knee injuries: comparison of the physical examination and magnetic resonance imaging with the findings from arthroscopy☆

    PubMed Central

    Orlando Júnior, Nilton; de Souza Leão, Marcos George; de Oliveira, Nelson Henrique Carvalho

    2015-01-01

    Objectives To ascertain the sensitivity, specificity, accuracy and concordance of the physical examination (PE) and magnetic resonance imaging (MRI) in comparison with arthroscopy, in diagnosing knee injuries. Methods Prospective study on 72 patients, with evaluation and comparison of PE, MRI and arthroscopic findings, to determine the concordance, accuracy, sensitivity and specificity. Results PE showed sensitivity of 75.00%, specificity of 62.50% and accuracy of 69.44% for medial meniscal (MM) lesions, while it showed sensitivity of 47.82%, specificity of 93.87% and accuracy of 79.16% for lateral meniscal (LM) lesions. For anterior cruciate ligament (ACL) injuries, PE showed sensitivity of 88.67%, specificity of 94.73% and accuracy of 90.27%. For MM lesions, MRI showed sensitivity of 92.50%, specificity of 62.50% and accuracy of 69.44%, while for LM injuries, it showed sensitivity of 65.00%, specificity of 88.46% and accuracy of 81.94%. For ACL injuries, MRI showed sensitivity of 86.79%, specificity of 73.68% and accuracy of 83.33%. For ACL injuries, the best concordance was with PE, while for MM and LM lesions, it was with MRI (p < 0.001). Conclusions Meniscal and ligament injuries can be diagnosed through careful physical examination, while requests for MRI are reserved for complex or doubtful cases. PE and MRI used together have high sensitivity for ACL and MM lesions, while for LM lesions the specificity is higher. Level of evidence II – Development of diagnostic criteria on consecutive patients (with universally applied reference “gold” standard). PMID:27218085

  2. A Performance Comparison of Color Vision Tests for Military Screening.

    PubMed

    Walsh, David V; Robinson, James; Jurek, Gina M; Capó-Aponte, José E; Riggs, Daniel W; Temme, Leonard A

    2016-04-01

    Current color vision (CV) tests used for aviation screening in the U.S. Army only provide pass-fail results, and previous studies have shown variable sensitivity and specificity. The purpose of this study was to evaluate seven CV tests to determine an optimal CV test screener that potentially could be implemented by the U.S. Army. There were 133 subjects [65 Color Vision Deficits (CVD), 68 Color Vision Normal (CVN)] who performed all of the tests in one setting. CVD and CVN determination was initially assessed with the Oculus anomaloscope. Each test was administered monocularly and according to the test protocol. The main outcome measures were test sensitivity, specificity, and administration time (automated tests). Three of the four Pseudoisochromatic Plate (PIP) tests had a sensitivity/specificity > 0.90 OD/OS, whereas the FALANT tests had a sensitivity/specificity > 0.80 OD/OS. The Cone Contrast Test (CCT) demonstrated sensitivity/specificity > 0.90 OD/OS, whereas the Color Assessment and Diagnosis (CAD) test demonstrated sensitivity/specificity > 0.85 OD/OS. Comparison with the anomaloscope ("gold standard") revealed no significant difference of sensitivity and specificity OD/OS with the CCT, Dvorine PIP, and PIPC tests. Finally, the CCT administration time was significantly faster than the CAD test. The current U.S. Army CV screening tests demonstrated good sensitivity and specificity, as did the automated tests. In addition, some current PIP tests (Dvorine, PIPC), and the CCT performed no worse statistically than the anomaloscope with regard to sensitivity/specificity. The CCT letter presentation is randomized and results would not be confounded by potential memorization, or fading, of book plates.

  3. Accuracy of line probe assays for the diagnosis of pulmonary and multidrug-resistant tuberculosis: a systematic review and meta-analysis

    PubMed Central

    Cudahy, Patrick G.T; Schumacher, Samuel G.; Steingart, Karen R.; Pai, Madhukar; Denkinger, Claudia M.

    2017-01-01

    Only 25% of multidrug-resistant tuberculosis (MDR-TB) cases are currently diagnosed. Line probe assays (LPAs) enable rapid drug-susceptibility testing for rifampicin (RIF) and isoniazid (INH) resistance and Mycobacterium tuberculosis detection. Genotype MTBDRplusV1 was WHO-endorsed in 2008 but newer LPAs have since been developed. This systematic review evaluated three LPAs: Hain Genotype MTBDRplusV1, MTBDRplusV2 and Nipro NTM+MDRTB. Study quality was assessed with QUADAS-2. Bivariate random-effects meta-analyses were performed for direct and indirect testing. Results for RIF and INH resistance were compared to phenotypic and composite (incorporating sequencing) reference standards. M. tuberculosis detection results were compared to culture. 74 unique studies were included. For RIF resistance (21 225 samples), pooled sensitivity and specificity (with 95% confidence intervals) were 96.7% (95.6–97.5%) and 98.8% (98.2–99.2%). For INH resistance (20 954 samples), pooled sensitivity and specificity were 90.2% (88.2–91.9%) and 99.2% (98.7–99.5%). Results were similar for direct and indirect testing and across LPAs. Using a composite reference standard, specificity increased marginally. For M. tuberculosis detection (3451 samples), pooled sensitivity was 94% (89.4–99.4%) for smear-positive specimens and 44% (20.2–71.7%) for smear-negative specimens. In patients with pulmonary TB, LPAs have high sensitivity and specificity for RIF resistance and high specificity and good sensitivity for INH resistance. This meta-analysis provides evidence for policy and practice. PMID:28100546

  4. An administrative data validation study of the accuracy of algorithms for identifying rheumatoid arthritis: the influence of the reference standard on algorithm performance.

    PubMed

    Widdifield, Jessica; Bombardier, Claire; Bernatsky, Sasha; Paterson, J Michael; Green, Diane; Young, Jacqueline; Ivers, Noah; Butt, Debra A; Jaakkimainen, R Liisa; Thorne, J Carter; Tu, Karen

    2014-06-23

    We have previously validated administrative data algorithms to identify patients with rheumatoid arthritis (RA) using rheumatology clinic records as the reference standard. Here we reassessed the accuracy of the algorithms using primary care records as the reference standard. We performed a retrospective chart abstraction study using a random sample of 7500 adult patients under the care of 83 family physicians contributing to the Electronic Medical Record Administrative data Linked Database (EMRALD) in Ontario, Canada. Using physician-reported diagnoses as the reference standard, we computed and compared the sensitivity, specificity, and predictive values for over 100 administrative data algorithms for RA case ascertainment. We identified 69 patients with RA for a lifetime RA prevalence of 0.9%. All algorithms had excellent specificity (>97%). However, sensitivity varied (75-90%) among physician billing algorithms. Despite the low prevalence of RA, most algorithms had adequate positive predictive value (PPV; 51-83%). The algorithm of "[1 hospitalization RA diagnosis code] or [3 physician RA diagnosis codes with ≥1 by a specialist over 2 years]" had a sensitivity of 78% (95% CI 69-88), specificity of 100% (95% CI 100-100), PPV of 78% (95% CI 69-88) and NPV of 100% (95% CI 100-100). Administrative data algorithms for detecting RA patients achieved a high degree of accuracy amongst the general population. However, results varied slightly from our previous report, which can be attributed to differences in the reference standards with respect to disease prevalence, spectrum of disease, and type of comparator group.

  5. The Sensitivity of Adolescent Hearing Screens Significantly Improves by Adding High Frequencies.

    PubMed

    Sekhar, Deepa L; Zalewski, Thomas R; Beiler, Jessica S; Czarnecki, Beth; Barr, Ashley L; King, Tonya S; Paul, Ian M

    2016-09-01

    One in 6 US adolescents has high-frequency hearing loss, often related to hazardous noise. Yet, the American Academy of Pediatrics (AAP) hearing screen (500, 1,000, 2,000, 4,000 Hertz) primarily includes low frequencies (<3,000 Hertz). Study objectives were to determine (1) sensitivity and specificity of the AAP hearing screen for adolescent hearing loss and (2) if adding high frequencies increases sensitivity, while repeat screening of initial referrals reduces false positive results (maintaining acceptable specificity). Eleventh graders (n = 134) participated in hearing screening (2013-2014) including "gold-standard" sound-treated booth testing to calculate sensitivity and specificity. Of the 43 referrals, 27 (63%) had high-frequency hearing loss. AAP screen sensitivity and specificity were 58.1% (95% confidence interval 42.1%-73.0%) and 91.2% (95% confidence interval 83.4-96.1), respectively. Adding high frequencies (6,000, 8,000 Hertz) significantly increased sensitivity to 79.1% (64.0%-90.0%; p = .003). Specificity with repeat screening was 81.3% (71.8%-88.7%; p = .003). Adolescent hearing screen sensitivity improves with high frequencies. Repeat testing maintains acceptable specificity. Copyright © 2016 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.

  6. 3D-CAM: Derivation and Validation of a 3-Minute Diagnostic Interview for CAM-defined Delirium

    PubMed Central

    Marcantonio, Edward R.; Ngo, Long H.; O’Connor, Margaret; Jones, Richard N.; Crane, Paul K.; Metzger, Eran D.; Inouye, Sharon K.

    2015-01-01

    Background Delirium is common, morbid, and costly, yet remains often unrecognized in most clinical settings. The Confusion Assessment Method (CAM) is the most widely used diagnostic algorithm, and operationalizing its features would represent a substantial advance for clinical care. Objective To derive the 3D-CAM, a new 3-minute diagnostic assessment for CAM-defined delirium, and to validate it against a clinical reference standard. Design Diagnostic test study Setting 4 general medicine units in an academic medical center Participants 201 inpatients aged ≥ 75 years old Measurements We identified 20 items that best operationalized the 4 CAM diagnostic features to create the 3D-CAM. For prospective validation, 3D-CAM assessments were administered by trained research assistants. Independently, clinicians performed an extensive assessment that included patient interviews, family interviews, and review of the medical record. These data were considered by an expert panel to determine the presence or absence of delirium and dementia (reference standard). We compared the 3D-CAM delirium determination to the reference standard in all patients and in subgroups with and without dementia. Results The 201 participants in the prospective validation study had mean age (SD) of 84 (5.5) years, and 27% had dementia. The expert panel identified delirium in 21%. Median administration time for 3D-CAM was 3 minutes (inter-quartile range: 2–5 minutes). The sensitivity [95% CI] of 3D-CAM was 95% [84%, 99%] and the specificity was 94% [90%, 97%]. The 3D-CAM performed well in patients both with dementia (sensitivity=96% [82%, 100%], specificity=86% [67%, 96%]) and without dementia (sensitivity=93% [66%, 100%], specificity=96% [91%,99%]). Limitations Limited to single center, cross-sectional, and medicine patients only Conclusion The 3D-CAM operationalizes the CAM algorithm using a 3-minute structured assessment with high sensitivity and specificity relative to a reference standard and could be an important tool for improving recognition of delirium. PMID:25329203

  7. Comparison of the Sanofi Diagnostics Pasteur Chlamydia Microplate EIA shortened assay with the original standard assay and cell culture.

    PubMed

    Chan, E L; Brandt, K; Stoneham, H; Horsman, G

    1997-08-01

    The new Sanofi Diagnostics Pasteur Chlamydia Microplate EIA shortened assay was evaluated by comparison with the original standard assay and cell culture. A total of 853 paired male and female genital tract specimens was tested with both Sanofi Chlamydia Microplate EIA shortened and standard assays and the results were compared with those of cell culture. For confirmation, a blocking assay run in the shortened format was used. Discrepancies between the three methods were resolved by a direct fluorescent antibody (DFA) test on the EIA samples or the culture retentate, or both. After resolution of discrepant results, the standard assay had a sensitivity, specificity, positive predictive value and negative predictive value of 98.5%, 100%, 100% and 99.9%, respectively. The shortened assay results were 100%, 100%, 100% and 100%, respectively. The shortened assay takes approximately 1.5 h less time than the standard assay and this study demonstrated that they have equivalent sensitivity and specificity. The improvement in turnaround time enables results to be reported on the same day.

  8. The dream of a one-stop-shop: Meta-analysis on myocardial perfusion CT.

    PubMed

    Pelgrim, Gert Jan; Dorrius, Monique; Xie, Xueqian; den Dekker, Martijn A M; Schoepf, U Joseph; Henzler, Thomas; Oudkerk, Matthijs; Vliegenthart, Rozemarijn

    2015-12-01

    To determine the diagnostic performance of computed tomography (CT) perfusion techniques for the detection of functionally relevant coronary artery disease (CAD) in comparison to reference standards, including invasive coronary angiography (ICA), single photon emission computed tomography (SPECT), and magnetic resonance imaging (MRI). PubMed, Web of Knowledge and Embase were searched from January 1, 1998 until July 1, 2014. The search yielded 9475 articles. After duplicate removal, 6041 were screened on title and abstract. The resulting 276 articles were independently analyzed in full-text by two reviewers, and included if the inclusion criteria were met. The articles reporting diagnostic parameters including true positive, true negative, false positive and false negative were subsequently evaluated for the meta-analysis. Results were pooled according to CT perfusion technique, namely snapshot techniques: single-phase rest, single-phase stress, single-phase dual-energy stress and combined coronary CT angiography [rest] and single-phase stress, as well the dynamic technique: dynamic stress CT perfusion. Twenty-two articles were included in the meta-analysis (1507 subjects). Pooled per-patient sensitivity and specificity of single-phase rest CT compared to rest SPECT were 89% (95% confidence interval [CI], 82-94%) and 88% (95% CI, 78-94%), respectively. Vessel-based sensitivity and specificity of single-phase stress CT compared to ICA-based >70% stenosis were 82% (95% CI, 64-92%) and 78% (95% CI, 61-89%). Segment-based sensitivity and specificity of single-phase dual-energy stress CT in comparison to stress MRI were 75% (95% CI, 60-85%) and 95% (95% CI, 80-99%). Segment-based sensitivity and specificity of dynamic stress CT perfusion compared to stress SPECT were 77% (95% CI, 67-85) and 89% (95% CI, 78-95%). For combined coronary CT angiography and single-phase stress CT, vessel-based sensitivity and specificity in comparison to ICA-based >50% stenosis were 84% (95% CI, 67-93%) and 93% (95% CI, 89-96%). This meta-analysis shows considerable variation in techniques and reference standards for CT of myocardial blood supply. While CT seems sensitive and specific for evaluation of hemodynamically relevant CAD, studies so far are limited in size. Standardization of myocardial perfusion CT technique is essential. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  9. Sensitivity and specificity of criteria for classifying body mass index in adolescents.

    PubMed

    Farias Júnior, José Cazuza de; Konrad, Lisandra Maria; Rabacow, Fabiana Maluf; Grup, Susane; Araújo, Valbério Candido

    2009-02-01

    To estimate the prevalence of overweight among adolescents using different body mass index (BMI) classification criteria, and to determine sensitivity and specificity values for these criteria. Weight, height, and tricipital and subscapular skinfolds in 934 adolescents (462 males and 472 females) aged 14-18 years (mean age 16.2; SD=1.0) of the city of Florianópolis, Southern Brazil, in 2001. Percent fat estimated based on skinfold measurements (> or =25% in males and > or =30% in females) was used as a gold-standard for determining specificity and sensitivity of BMI classification criteria among adolescents. The different cutoff points used for classifying BMI in general resulted in similar prevalence of overweight (p>0.05). Sensitivity of the evaluated criteria was high for males (85.4% to 91.7%) and low for females (33.8 to 52.8%). Specificity of all criteria was high for both sexes (83.6% to 98.8%). Estimates of prevalence of obesity among adolescents using different BMI classification criteria were similar and highly specific for both sexes, but sensitivity for females was low.

  10. Improved cardiovascular diagnostic accuracy by pocket size imaging device in non-cardiologic outpatients: the NaUSiCa (Naples Ultrasound Stethoscope in Cardiology) study

    PubMed Central

    2010-01-01

    Miniaturization has evolved in the creation of a pocket-size imaging device which can be utilized as an ultrasound stethoscope. This study assessed the additional diagnostic power of pocket size device by both experts operators and trainees in comparison with physical examination and its appropriateness of use in comparison with standard echo machine in a non-cardiologic population. Three hundred four consecutive non cardiologic outpatients underwent a sequential assessment including physical examination, pocket size imaging device and standard Doppler-echo exam. Pocket size device was used by both expert operators and trainees (who received specific training before the beginning of the study). All the operators were requested to give only visual, qualitative insights on specific issues. All standard Doppler-echo exams were performed by expert operators. One hundred two pocket size device exams were performed by experts and two hundred two by trainees. The time duration of the pocket size device exam was 304 ± 117 sec. Diagnosis of cardiac abnormalities was made in 38.2% of cases by physical examination and in 69.7% of cases by physical examination + pocket size device (additional diagnostic power = 31.5%, p < 0.0001). The overall K between pocket size device and standard Doppler-echo was 0.67 in the pooled population (0.84 by experts and 0.58 by trainees). K was suboptimal for trainees in the eyeball evaluation of ejection fraction, left atrial dilation and right ventricular dilation. Overall sensitivity was 91% and specificity 76%. Sensitivity and specificity were lower in trainees than in experts. In conclusion, pocket size device showed a relevant additional diagnostic value in comparison with physical examination. Sensitivity and specificity were good in experts and suboptimal in trainees. Specificity was particularly influenced by the level of experience. Training programs are needed for pocket size device users. PMID:21110840

  11. Sensitivity and specificity of Norwegian optometrists’ evaluation of diabetic retinopathy in single-field retinal images – a cross-sectional experimental study

    PubMed Central

    2013-01-01

    Background In the working age group, diabetic retinopathy is a leading cause of visual impairment. Regular eye examinations and early treatment of retinopathy can prevent visual loss, so screening for diabetic retinopathy is cost-effective. Dilated retinal digital photography with the additional use of ophthalmoscopy is the most effective and robust method of diabetic retinopathy screening. The aim of this study was to estimate the sensitivity and specificity of diabetic retinopathy screening when performed by Norwegian optometrists. Methods This study employed a cross-sectional experimental design. Seventy-four optometrists working in private optometric practice were asked to screen 14 single-field retinal images for possible diabetic retinopathy. The screening was undertaken using a web-based visual identification and management of ophthalmological conditions (VIMOC) examination. The images used in the VIMOC examination were selected from a population survey and had been previously examined by two independent ophthalmologists. In order to establish a “gold standard”, images were only chosen for use in the VIMOC examination if they had elicited diagnostic agreement between the two independent ophthalmologists. To reduce the possibility of falsely high specificity occurring by chance, half the presented images were of retinas that were not affected by diabetic retinopathy. Sensitivity and specificity for diabetic retinopathy was calculated with 95% confidence intervals (CIs). Results The mean (95%CI) sensitivity for identifying eyes with any diabetic retinopathy was 67% (62% to 72%). The mean (95%CI) specificity for identifying eyes without diabetic retinopathy was 84% (80% to 89%). The mean (95%CI) sensitivity for identifying eyes with mild non-proliferative diabetic retinopathy or moderate non-proliferative diabetes was 54% (47% to 61%) and 100%, respectively. Only four optometrists (5%) met the required standard of at least 80% sensitivity and 95% specificity that has been previously set for diabetic retinopathy screening programmes. Conclusions The evaluation of retinal images for diabetic retinopathy by Norwegian optometrists does not meet the required screening standard of at least 80% sensitivity and 95% specificity. The introduction of measures to improve this situation could have implications for both formal optometric training and continuing optometric professional education. PMID:23305337

  12. An evaluation of a rapid real time polymerase chain reaction assay for detection of group B streptococcus as part of a neonatal group B streptococcus prevention strategy.

    PubMed

    Money, Deborah; Dobson, Simon; Cole, Lesley; Karacabeyli, Eda; Blondel-Hill, Edith; Milner, Ruth; Thomas, Eva

    2008-09-01

    To evaluate the sensitivity, specificity, and feasibility of a rapid real-time polymerase chain reaction (PCR) test for group B streptococcus (GBS) completed during labour, compared with the standard culture test performed at 35 to 37 weeks' gestation. Women presenting to the maternity unit for term vaginal delivery had two vaginal/rectal samples collected. One swab was tested using a rapid PCR method (IDI-Strep B, Infectio Diagnostic [IDI] Inc., Sainte-Foy QC ), and the other was cultured after enrichment (intrapartum culture). Comparisons were made between these results and those of a culture-based screen at 35 to 37 weeks' gestation. Of the 190 women enrolled, 85% had results of the standard screen at 35 to 37 weeks available for comparison. The sensitivity and specificity of the standard 35- to 37-week screen were 84.3% (95% confidence interval [CI], 71.4-93.0) and 93.2% (95% CI 86.5-97.2) respectively, whereas the sensitivity and specificity of the rapid PCR were 90.7% (95% CI 79.7-96.9) and 97.6% (95% CI 93.1-99.5), respectively. The median reporting time for the rapid PCR test was 99 minutes (range 50-255). Results were available more than four hours before delivery in 81% of cases. In this Canadian centre, a rapid PCR test done at the time of labour (IDI-Strep B) demonstrated high sensitivity and specificity, comparable to the 35- to 37-week screen. The time to reporting results was acceptably short, allowing for timely administration of intrapartum prophylactic antibiotics.

  13. Improved Automated Detection of Diabetic Retinopathy on a Publicly Available Dataset Through Integration of Deep Learning.

    PubMed

    Abràmoff, Michael David; Lou, Yiyue; Erginay, Ali; Clarida, Warren; Amelon, Ryan; Folk, James C; Niemeijer, Meindert

    2016-10-01

    To compare performance of a deep-learning enhanced algorithm for automated detection of diabetic retinopathy (DR), to the previously published performance of that algorithm, the Iowa Detection Program (IDP)-without deep learning components-on the same publicly available set of fundus images and previously reported consensus reference standard set, by three US Board certified retinal specialists. We used the previously reported consensus reference standard of referable DR (rDR), defined as International Clinical Classification of Diabetic Retinopathy moderate, severe nonproliferative (NPDR), proliferative DR, and/or macular edema (ME). Neither Messidor-2 images, nor the three retinal specialists setting the Messidor-2 reference standard were used for training IDx-DR version X2.1. Sensitivity, specificity, negative predictive value, area under the curve (AUC), and their confidence intervals (CIs) were calculated. Sensitivity was 96.8% (95% CI: 93.3%-98.8%), specificity was 87.0% (95% CI: 84.2%-89.4%), with 6/874 false negatives, resulting in a negative predictive value of 99.0% (95% CI: 97.8%-99.6%). No cases of severe NPDR, PDR, or ME were missed. The AUC was 0.980 (95% CI: 0.968-0.992). Sensitivity was not statistically different from published IDP sensitivity, which had a CI of 94.4% to 99.3%, but specificity was significantly better than the published IDP specificity CI of 55.7% to 63.0%. A deep-learning enhanced algorithm for the automated detection of DR, achieves significantly better performance than a previously reported, otherwise essentially identical, algorithm that does not employ deep learning. Deep learning enhanced algorithms have the potential to improve the efficiency of DR screening, and thereby to prevent visual loss and blindness from this devastating disease.

  14. Evaluation of the SD Bioline Cholera Rapid Diagnostic Test During the 2016 Cholera Outbreak in Lusaka, Zambia.

    PubMed

    Mwaba, John; Ferreras, Eva; Chizema-Kawesa, Elizabeth; Mwimbe, Daniel; Tafirenyika, Francis; Rauzier, Jean; Blake, Alexandre; Rakesh, Ankur; Poncin, Marc; Stoitsova, Savina; Kwenda, Geoffrey; Azman, Andrew S; Chewe, Orbrie; Serafini, Micaela; Lukwesa-Musyani, Chileshe; Cohuet, Sandra; Quilici, Marie-Laure; Luquero, Francisco J; Page, Anne-Laure

    2018-05-31

    To assess the performance of the SD Bioline Cholera Ag O1/O139 rapid diagnostic test (RDT) compared to a reference standard combining culture and PCR for the diagnosis of cholera cases during an outbreak. RDT and bacterial culture were performed on site using fresh stools collected from cholera suspected cases, and from stools enriched in alkaline peptone water. Dried stool samples on filter paper were tested for V. cholerae by PCR in Lusaka (as part of a laboratory technology transfer project) and at a reference laboratory in Paris, France. A sample was considered positive for cholera by the reference standard if any of the culture or PCR tests was positive for V. cholerae O1 or O139. Among the 170 samples tested with SD Bioline and compared to the reference standard, the RDT showed a sensitivity of 90.9% (95% CI: 81.3-96.6) and specificity of 95.0% (95% CI: 89.1-98.4). After enrichment, the sensitivity was 95.5% (95% CI: 87.3-99.1) and specificity 100% (5% CI: 96.5-100). The observed sensitivity and specificity were within recommendations set by the Global Task Force for Cholera Control on the use of cholera RDT (sensitivity=90% : specificity=85%). Although the sample size was small, our findings suggest that the SD Bioline RDT could be used in the field to rapidly alert public health officials to the likely presence of cholera cases when an outbreak is suspected. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  15. Diagnostic accuracy of administrative data algorithms in the diagnosis of osteoarthritis: a systematic review.

    PubMed

    Shrestha, Swastina; Dave, Amish J; Losina, Elena; Katz, Jeffrey N

    2016-07-07

    Administrative health care data are frequently used to study disease burden and treatment outcomes in many conditions including osteoarthritis (OA). OA is a chronic condition with significant disease burden affecting over 27 million adults in the US. There are few studies examining the performance of administrative data algorithms to diagnose OA. The purpose of this study is to perform a systematic review of administrative data algorithms for OA diagnosis; and, to evaluate the diagnostic characteristics of algorithms based on restrictiveness and reference standards. Two reviewers independently screened English-language articles published in Medline, Embase, PubMed, and Cochrane databases that used administrative data to identify OA cases. Each algorithm was classified as restrictive or less restrictive based on number and type of administrative codes required to satisfy the case definition. We recorded sensitivity and specificity of algorithms and calculated positive likelihood ratio (LR+) and positive predictive value (PPV) based on assumed OA prevalence of 0.1, 0.25, and 0.50. The search identified 7 studies that used 13 algorithms. Of these 13 algorithms, 5 were classified as restrictive and 8 as less restrictive. Restrictive algorithms had lower median sensitivity and higher median specificity compared to less restrictive algorithms when reference standards were self-report and American college of Rheumatology (ACR) criteria. The algorithms compared to reference standard of physician diagnosis had higher sensitivity and specificity than those compared to self-reported diagnosis or ACR criteria. Restrictive algorithms are more specific for OA diagnosis and can be used to identify cases when false positives have higher costs e.g. interventional studies. Less restrictive algorithms are more sensitive and suited for studies that attempt to identify all cases e.g. screening programs.

  16. Bias in estimating accuracy of a binary screening test with differential disease verification

    PubMed Central

    Brinton, John T.; Ringham, Brandy M.; Glueck, Deborah H.

    2011-01-01

    SUMMARY Sensitivity, specificity, positive and negative predictive value are typically used to quantify the accuracy of a binary screening test. In some studies it may not be ethical or feasible to obtain definitive disease ascertainment for all subjects using a gold standard test. When a gold standard test cannot be used an imperfect reference test that is less than 100% sensitive and specific may be used instead. In breast cancer screening, for example, follow-up for cancer diagnosis is used as an imperfect reference test for women where it is not possible to obtain gold standard results. This incomplete ascertainment of true disease, or differential disease verification, can result in biased estimates of accuracy. In this paper, we derive the apparent accuracy values for studies subject to differential verification. We determine how the bias is affected by the accuracy of the imperfect reference test, the percent who receive the imperfect reference standard test not receiving the gold standard, the prevalence of the disease, and the correlation between the results for the screening test and the imperfect reference test. It is shown that designs with differential disease verification can yield biased estimates of accuracy. Estimates of sensitivity in cancer screening trials may be substantially biased. However, careful design decisions, including selection of the imperfect reference test, can help to minimize bias. A hypothetical breast cancer screening study is used to illustrate the problem. PMID:21495059

  17. Reference Standard Test and the Diagnostic Ability of Spectral Domain Optical Coherence Tomography in Glaucoma.

    PubMed

    Rao, Harsha L; Yadav, Ravi K; Addepalli, Uday K; Begum, Viquar U; Senthil, Sirisha; Choudhari, Nikhil S; Garudadri, Chandra S

    2015-08-01

    To evaluate the relationship between the reference standard used to diagnose glaucoma and the diagnostic ability of spectral domain optical coherence tomograph (SDOCT). In a cross-sectional study, 280 eyes of 175 consecutive subjects, referred to a tertiary eye care center for glaucoma evaluation, underwent optic disc photography, visual field (VF) examination, and SDOCT examination. The cohort was divided into glaucoma and control groups based on 3 reference standards for glaucoma diagnosis: first based on the optic disc classification (179 glaucoma and 101 control eyes), second on VF classification (glaucoma hemifield test outside normal limits and pattern SD with P-value of <5%, 130 glaucoma and 150 control eyes), and third on the presence of both glaucomatous optic disc and glaucomatous VF (125 glaucoma and 155 control eyes). Relationship between the reference standards and the diagnostic parameters of SDOCT were evaluated using areas under the receiver operating characteristic curve, sensitivity, and specificity. Areas under the receiver operating characteristic curve and sensitivities of most of the SDOCT parameters obtained with the 3 reference standards (ranging from 0.74 to 0.88 and 72% to 88%, respectively) were comparable (P>0.05). However, specificities of SDOCT parameters were significantly greater (P<0.05) with optic disc classification as reference standard (74% to 88%) compared with VF classification as reference standard (57% to 74%). Diagnostic parameters of SDOCT that was significantly affected by reference standard was the specificity, which was greater with optic disc classification as the reference standard. This has to be considered when comparing the diagnostic ability of SDOCT across studies.

  18. Development and evaluation of an immunochromatographic assay using a gp51 monoclonal antibody for the detection of antibodies against the bovine leukemia virus.

    PubMed

    Kim, Eun-Ju; Cheong, Kwang-Myun; Joung, Ha-Kyung; Kim, Bo-Hye; Song, Jae-Young; Cho, In-Soo; Lee, Kyoung-Ki; Shin, Yeun-Kyung

    2016-12-30

    Infection of cattle with bovine leukemia virus (BLV) has been observed and reported worldwide, including in Korea. The onsite identification of infected cattle would help decreasing and eradicating BLV infections on farms. Here, we present a new immunochromatographic assay that employs monoclonal antibodies (MAbs) for the detection of antibodies against BLV in the field. BLV envelope glycoprotein (gp)51 was expressed in E. coli , and MAbs against recombinant BLV gp51 were generated for the development of an immunochromatographic assay to detect BLV antibodies in cattle. The sensitivity and specificity of the assay were determined by comparing these results with those obtained from a standard enzyme linked immunosorbent assay (ELISA). A total of 160 bovine sera were used to evaluate the new immunochromatographic assay. Using ELISA as a reference standard, the relative specificity and sensitivity of this assay were determined to be 94.7% and 98%, respectively. Because of its high sensitivity and specificity, this BLV antibody detection assay would be suitable for the onsite identification of BLV infection in the field.

  19. PubMed search filters for the study of putative outdoor air pollution determinants of disease.

    PubMed

    Curti, Stefania; Gori, Davide; Di Gregori, Valentina; Farioli, Andrea; Baldasseroni, Alberto; Fantini, Maria Pia; Christiani, David C; Violante, Francesco S; Mattioli, Stefano

    2016-12-21

    Several PubMed search filters have been developed in contexts other than environmental. We aimed at identifying efficient PubMed search filters for the study of environmental determinants of diseases related to outdoor air pollution. We compiled a list of Medical Subject Headings (MeSH) and non-MeSH terms seeming pertinent to outdoor air pollutants exposure as determinants of diseases in the general population. We estimated proportions of potentially pertinent articles to formulate two filters (one 'more specific', one 'more sensitive'). Their overall performance was evaluated as compared with our gold standard derived from systematic reviews on diseases potentially related to outdoor air pollution. We tested these filters in the study of three diseases potentially associated with outdoor air pollution and calculated the number of needed to read (NNR) abstracts to identify one potentially pertinent article in the context of these diseases. Last searches were run in January 2016. The 'more specific' filter was based on the combination of terms that yielded a threshold of potentially pertinent articles ≥40%. The 'more sensitive' filter was based on the combination of all search terms under study. When compared with the gold standard, the 'more specific' filter reported the highest specificity (67.4%; with a sensitivity of 82.5%), while the 'more sensitive' one reported the highest sensitivity (98.5%; with a specificity of 47.9%). The NNR to find one potentially pertinent article was 1.9 for the 'more specific' filter and 3.3 for the 'more sensitive' one. The proposed search filters could help healthcare professionals investigate environmental determinants of medical conditions that could be potentially related to outdoor air pollution. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  20. [Meta-analysis of diagnostic capability of frequency-doubling technology (FDT) for primary glaucoma].

    PubMed

    Liu, Ting; He, Xiang-ge

    2006-05-01

    To evaluate the overall diagnostic capabilities of frequency-doubling technology (FDT) in patients of primary glaucoma, with standard automated perimetry (SAP) and/or optic disc appearance as the gold standard. A comprehensive electric search in MEDLINE, EMBASE, Cochrane Library, BIOSIS, Previews, HMIC, IPA, OVID, CNKI, CBMdisc, VIP information, CMCC, CCPD, SSreader and 21dmedia and a manual search in related textbooks, journals, congress articles and their references were performed to identify relevant English and Chinese language articles. Criteria for adaptability were established according to validity criteria for diagnostic research published by the Cochrane Methods Group on Screening and Diagnostic Tests. Quality of the included articles was assessed and relevant materials were extracted for studying. Statistical analysis was performed with Meta Test version 0.6 software. Heterogeneity of the included articles was tested, which was used to select appropriate effect model to calculate pooled weighted sensitivity and specificity. Summary Receiver Operating Characteristic (SROC) curve was established and the area under the curve (AUC) was calculated. Finally, sensitivity analysis was performed. Fifteen English articles (21 studies) of 206 retrieved articles were included in the present study, with a total of 3172 patients. The reported sensitivity of FDT ranged from 0.51 to 1.00, and specificity from 0.58 to 1.00. The pooled weighted sensitivity and specificity for FDT with 95% confidence intervals (95% CI) after correction for standard error were 0.86 (0.80 - 0.90), 0.87 (0.81 - 0.91), respectively. The AUC of SROC was 93.01%. Sensitivity analysis demonstrated no disproportionate influences of individual study. The included articles are of good quality and FDT can be a highly efficient diagnostic test for primary glaucoma based on Meta-analysis. However, a high quality perspective study is still required for further analysis.

  1. Development of a Highly Sensitive Nested-PCR Procedure Using a Single Closed Tube for Detection of Erwinia amylovora in Asymptomatic Plant Material

    PubMed Central

    Llop, Pablo; Bonaterra, Anna; Peñalver, Javier; López, María M.

    2000-01-01

    A novel method, which involves a nested PCR in a single closed tube, was developed for the sensitive detection of Erwinia amylovora in plant material. The external and internal primer pairs used had different annealing temperatures and directed the amplification of a specific DNA fragment from plasmid pEA29. The procedure involved two consecutive PCRs, the first of which was performed at a higher annealing temperature that allowed amplification only by the external primer pair. Using pure cultures of E. amylovora, the sensitivity of the nested PCR in one tube was similar to that of a standard nested PCR in two tubes. The specificity and sensitivity were greater than those of standard PCR procedures that used a single primer pair. The presence of inhibitors in plant material, very common in E. amylovora hosts, is overcome with this system in combination with a simple DNA extraction protocol because it eliminates many of the inhibitory compounds. In addition, it needs a very small sample volume (1 μl of DNA extracted). With 83 samples of naturally infected material, this method achieved better results than any other PCR technique: standard PCR detected 55% of positive samples, two-tube nested PCR detected 71% of positive samples, and nested PCR in a single closed tube detected 78% of positive samples. When analyzing asymptomatic plant material, the number of positive samples detected by the developed nested PCR was also the highest, compared with the PCR protocols indicated previously (17, 20, and 25% of 251 samples analyzed, respectively). This method is proposed for the detection of endophytic and epiphytic populations of E. amylovora in epidemiological studies and for routine use in quarantine surveys, due to its high sensitivity, specificity, speed, and simplicity. PMID:10788384

  2. Evaluation of the OnSite (Pf/Pan) rapid diagnostic test for diagnosis of clinical malaria.

    PubMed

    Mohon, Abu Naser; Elahi, Rubayet; Podder, Milka Patracia; Mohiuddin, Khaja; Hossain, Mohammad Sharif; Khan, Wasif A; Haque, Rashidul; Alam, Mohammad Shafiul

    2012-12-12

    Accurate diagnosis of malaria is an essential prerequisite for proper treatment and drug resistance monitoring. Microscopy is considered the gold standard for malaria diagnosis but has limitations. ELISA, PCR, and Real Time PCR are also used to diagnose malaria in reference laboratories, although their application at the field level is currently not feasible. Rapid diagnostic tests (RDTs) however, have been brought into field operation and widely adopted in recent days. This study evaluates OnSite (Pf/Pan) antigen test, a new RDT introduced by CTK Biotech Inc, USA for malaria diagnosis in a reference setting. Blood samples were collected from febrile patients referred for malaria diagnosis by clinicians. Subjects were included in this study from two different Upazila Health Complexes (UHCs) situated in two malaria endemic districts of Bangladesh. Microscopy and nested PCR were considered the gold standard in this study. OnSite (Pf/Pan) RDT was performed on preserved whole blood samples. In total, 372 febrile subjects were included in this study. Of these subjects, 229 (61.6%) tested positive for Plasmodium infection detected by microscopy and nested PCR. OnSite (Pf/Pan) RDT was 94.2% sensitive (95% CI, 89.3-97.3) and 99.5% specific (95% CI, 97.4-00.0) for Plasmodium falciparum diagnosis and 97.3% sensitive (95% CI, 90.5-99.7) and 98.7% specific (95% CI, 96.6-99.6) for Plasmodium vivax diagnosis. Sensitivity varied with differential parasite count for both P. falciparum and P. vivax. The highest sensitivity was observed in febrile patients with parasitaemia that ranged from 501-1,000 parasites/μL regardless of the Plasmodium species. The new OnSite (Pf/Pan) RDT is both sensitive and specific for symptomatic malaria diagnosis in standard laboratory conditions.

  3. Record of hospitalizations for ambulatory care sensitive conditions: validation of the hospital information system.

    PubMed

    Rehem, Tania Cristina Morais Santa Barbara; de Oliveira, Maria Regina Fernandes; Ciosak, Suely Itsuko; Egry, Emiko Yoshikawa

    2013-01-01

    To estimate the sensitivity, specificity and positive and negative predictive values of the Unified Health System's Hospital Information System for the appropriate recording of hospitalizations for ambulatory care-sensitive conditions. The hospital information system records for conditions which are sensitive to ambulatory care, and for those which are not, were considered for analysis, taking the medical records as the gold standard. Through simple random sampling, a sample of 816 medical records was defined and selected by means of a list of random numbers using the Statistical Package for Social Sciences. The sensitivity was 81.89%, specificity was 95.19%, the positive predictive value was 77.61% and the negative predictive value was 96.27%. In the study setting, the Hospital Information System (SIH) was more specific than sensitive, with nearly 20% of care sensitive conditions not detected. There are no validation studies in Brazil of the Hospital Information System records for the hospitalizations which are sensitive to primary health care. These results are relevant when one considers that this system is one of the bases for assessment of the effectiveness of primary health care.

  4. A comparison of five serological tests for bovine brucellosis.

    PubMed Central

    Dohoo, I R; Wright, P F; Ruckerbauer, G M; Samagh, B S; Robertson, F J; Forbes, L B

    1986-01-01

    Five serological assays: the buffered plate antigen test, the standard tube agglutination test, the complement fixation test, the hemolysis-in-gel test and the indirect enzyme immunoassay were diagnostically evaluated. Test data consisted of results from 1208 cattle in brucellosis-free herds, 1578 cattle in reactor herds of unknown infection status and 174 cattle from which Brucella abortus had been cultured. The complement fixation test had the highest specificity in both nonvaccinated and vaccinated cattle. The indirect enzyme immunoassay, if interpreted at a high threshold, also exhibited a high specificity in both groups of cattle. The hemolysis-in-gel test had a very high specificity when used in nonvaccinated cattle but quite a low specificity among vaccinates. With the exception of the complement fixation test, all tests had high sensitivities if interpreted at the minimum threshold. However, the sensitivities of the standard tube agglutination test and indirect enzyme immunoassay, when interpreted at high thresholds were comparable to that of the complement fixation test. A kappa statistic was used to measure the agreement between the various tests. In general the kappa statistics were quite low, suggesting that the various tests may detect different antibody isotypes. There was however, good agreement between the buffered plate antigen test and standard tube agglutination test (the two agglutination tests evaluated) and between the complement fixation test and the indirect enzyme immunoassay when interpreted at a high threshold. With the exception of the buffered plate antigen test, all tests were evaluated as confirmatory tests by estimating their specificity and sensitivity on screening-test positive samples.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:3539295

  5. A comparison of standard serological tests for the diagnosis of bovine brucellosis in Canada.

    PubMed Central

    Stemshorn, B W; Forbes, L B; Eaglesome, M D; Nielsen, K H; Robertson, F J; Samagh, B S

    1985-01-01

    Six agglutination and two complement fixation tests were compared with respect to specificity, sensitivity and relative sensitivity for the serodiagnosis of bovine brucellosis. Based on 1051 sera from brucellosis free herds, the specificity of the tests was 98.9% for the buffered plate antigen test (BPAT), 99.2% and 99.3% for the standard tube and plate agglutination tests (STAT and SPAT), respectively, and 99.8% for the 2-mercaptoethanol test (2MET). On this small sample, the rose bengal plate test (RBPT), card test (CARD) and the complement fixation test (CFT) correctly classed all sera as negative. On a sample of 167 culture positive cattle, the sensitivities of the tests were CFT: 79.0%, BPAT: 75.4, RBPT: 74.9%, CARD: 74.3%, SPAT: 73.1%, STAT: 68.9%, and 2MET: 59.9%. All tests combined detected only 82% of these infected cattle. Analysis of the relative sensitivity of the six agglutination tests gave the following ranking: BPAT greater than RBPT greater than CARD greater than SPAT greater than STAT. The 2MET ranked between the BPAT and RBPT or between the RBPT and CARD depending on the analysis used. The use of the BPAT as a screening test is recommended provided that a test of high specificity and sensitivity such as the CFT is used to confirm screening test reactions. PMID:4075239

  6. Airway hyperresponsiveness to methacholine in 7-year-old children: sensitivity and specificity for pediatric allergist-diagnosed asthma.

    PubMed

    Carlsten, Chris; Dimich-Ward, Helen; Ferguson, Alexander; Becker, Allan; Dybuncio, Anne; Chan-Yeung, Moira

    2011-02-01

    The operating characteristics of PC(20) values used as cut-offs to define airway hyperresponsiveness, as it informs the diagnosis of asthma in children, are poorly understood. We examine data from a unique cohort to inform this concern. Determine the sensitivity and specificity of incremental PC(20) cut-offs for allergist-diagnosed asthma. Airway reactivity at age 7 was assessed in children within a birth cohort at high risk for asthma; PC(20) for methacholine was determined by standard technique including interpolation. The diagnosis of asthma was considered by the pediatric allergist without knowledge of the methacholine challenge results. Sensitivity and specificity were calculated using a cross-tabulation of asthma diagnosis with incremental PC(20) cut-off values, from 1.0 to 8.0 mg/ml, and plotted as receiver operator characteristic (ROC) curves. The "optimal" cut-off was defined as that PC(20) conferring maximal value for sensitivity plus specificity while the "balanced" cut-off was defined as that PC(20) at which sensitivity and specificity were most equal. 70/348 children (20.1%) were diagnosed with asthma. The optimal and balanced PC(20) cut-offs, both for all children and for females alone, were respectively 3 mg/ml (sensitivity 80.0%, specificity 49.1%) and 2 mg/ml (sensitivity 63.1%, specificity 64.7%). For males alone, the "optimal" and "balanced" PC(20) cut-offs were both 2 mg/ml. For this cohort of 7-year olds at high risk for asthma, methacholine challenge testing using a cut-off value of PC(20) 3 mg/ml conferred the maximal sum of specificity plus sensitivity. For contexts in which higher sensitivity or specificity is desired, other cut-offs may be preferred. Copyright © 2011 Wiley-Liss, Inc.

  7. Improved detection of CXCR4-using HIV by V3 genotyping: application of population-based and "deep" sequencing to plasma RNA and proviral DNA.

    PubMed

    Swenson, Luke C; Moores, Andrew; Low, Andrew J; Thielen, Alexander; Dong, Winnie; Woods, Conan; Jensen, Mark A; Wynhoven, Brian; Chan, Dennison; Glascock, Christopher; Harrigan, P Richard

    2010-08-01

    Tropism testing should rule out CXCR4-using HIV before treatment with CCR5 antagonists. Currently, the recombinant phenotypic Trofile assay (Monogram) is most widely utilized; however, genotypic tests may represent alternative methods. Independent triplicate amplifications of the HIV gp120 V3 region were made from either plasma HIV RNA or proviral DNA. These underwent standard, population-based sequencing with an ABI3730 (RNA n = 63; DNA n = 40), or "deep" sequencing with a Roche/454 Genome Sequencer-FLX (RNA n = 12; DNA n = 12). Position-specific scoring matrices (PSSMX4/R5) (-6.96 cutoff) and geno2pheno[coreceptor] (5% false-positive rate) inferred tropism from V3 sequence. These methods were then independently validated with a separate, blinded dataset (n = 278) of screening samples from the maraviroc MOTIVATE trials. Standard sequencing of HIV RNA with PSSM yielded 69% sensitivity and 91% specificity, relative to Trofile. The validation dataset gave 75% sensitivity and 83% specificity. Proviral DNA plus PSSM gave 77% sensitivity and 71% specificity. "Deep" sequencing of HIV RNA detected >2% inferred-CXCR4-using virus in 8/8 samples called non-R5 by Trofile, and <2% in 4/4 samples called R5. Triplicate analyses of V3 standard sequence data detect greater proportions of CXCR4-using samples than previously achieved. Sequencing proviral DNA and "deep" V3 sequencing may also be useful tools for assessing tropism.

  8. Comparative study of dot enzyme immunoassay (Typhidot-M) and Widal test in the diagnosis of typhoid fever.

    PubMed

    Narayanappa, D; Sripathi, Rachana; Jagdishkumar, K; Rajani, H S

    2010-04-01

    We compared the sensitivity and specificity of Typhidot-M and Widal test with blood culture (gold standard) for diagnosing typhoid fever in 105 children aged 1-15 years admitted with clinical suspicion of typhoid fever. Of the 105 cases, blood culture was positive for S.typhi in 41 (39%) children, Widal test was positive in 48 (45.7%) and Typhidot-M was positive in 78 (74.3%) cases. Sensitivity and specificity of Typhidot-M was 92.6% and 37.5% while sensitivity and specificity of Widal test was 34.1% and 42.8%, respectively. In children with fever of less than 7 days duration, Typhidot-M was positive in 97%, compared to 24.2% by Widal test. Typhidot-M is a simple and sensitive test for early diagnosis of typhoid fever in children.

  9. Histopathology of valves in infective endocarditis, diagnostic criteria and treatment considerations.

    PubMed

    Brandão, Tatiana J D; Januario-da-Silva, Carolina A; Correia, Marcelo G; Zappa, Monica; Abrantes, Jaime A; Dantas, Angela M R; Golebiovski, Wilma; Barbosa, Giovanna Ianini F; Weksler, Clara; Lamas, Cristiane C

    2017-04-01

    Infective endocarditis (IE) is a severe disease. Pathogen isolation is fundamental so as to treat effectively and reduce morbidity and mortality. Blood and valve culture and histopathology (HP) are routinely employed for this purpose. Valve HP is the gold standard for diagnosis. To determine the sensitivity and specificity of clinical criteria for IE (the modified Duke and the St Thomas' minor modifications, STH) of blood and valve culture compared to valve HP, and to evaluate antibiotic treatment duration. Prospective case series of patients, from 2006 to 2014 with surgically treated IE. Statistical analysis was done by the R software. There were 136 clinically definite episodes of IE in 133 patients. Mean age ± SD was 43 ± 15.6 years and IE was left sided in 81.6 %. HP was definite in 96 valves examined, which were used as gold standard. Sensitivity of blood culture was 61 % (CI 0.51, 0.71) and of valve culture 15 % (CI 0.07, 0.26). The modified Duke criteria were 65 % (CI 0.55, 0.75) sensitive and 33 % specific, while the STH's sensitivity was 72 % (CI 0.61, 0.80) with similar specificity. In multivariate analysis and logistic regression, the only variable with statistical significance was duration of antibiotic therapy postoperatively. Valve HP had high sensitivity and valve culture low sensitivity in the diagnosis of IE. The STH's criteria were more sensitive than the modified Duke criteria. Valve HP should guide duration of postoperative antibiotic treatment.

  10. The Sensitivity and Specificity of Potassium Hydroxide Smear and Fungal Culture Relative to Clinical Assessment in the Evaluation of Tinea Pedis: A Pooled Analysis

    PubMed Central

    Levitt, Jacob Oren; Levitt, Barrie H.; Akhavan, Arash; Yanofsky, Howard

    2010-01-01

    Background. There are relatively few studies published examining the sensitivity and specificity of potassium hydroxide (KOH) smear and fungal culture examination of tinea pedis. Objective. To evaluate the sensitivity and specificity of KOH smear and fungal culture for diagnosing tinea pedis. Methods. A pooled analysis of data from five similarly conducted bioequivalence trials for antifungal drugs was performed. Data from 460 patients enrolled in the vehicle arms of these studies with clinical diagnosis of tinea pedis supported by positive fungal culture were analyzed 6 weeks after initiation of the study to determine the sensitivity and specificity of KOH smear and fungal culture. Results. Using clinical assessment as the gold standard, the sensitivities for KOH smear and culture were 73.3% (95% CI: 66.3 to 79.5%) and 41.7% (34.6 to 49.1%), respectively. The respective specificities for culture and KOH smear were 77.7% (72.2 to 82.5%) and 42.5% (36.6 to 48.6%). Conclusion. KOH smear and fungal culture are complementary diagnostic tests for tinea pedis, with the former being the more sensitive test of the two, and the latter being more specific. PMID:20672004

  11. Electrical impedance myography in the diagnosis of radiculopathy.

    PubMed

    Spieker, Andrew J; Narayanaswami, Pushpa; Fleming, Laura; Keel, John C; Muzin, Stefan C; Rutkove, Seward B

    2013-11-01

    We sought to determine whether electrical impedance myography (EIM) could serve as a diagnostic procedure for evaluation of radiculopathy. Twenty-seven patients with clinically and radiologically diagnosed cervical or lumbosacral radiculopathy who met a "gold standard" definition underwent EIM and standard needle electromyography (EMG) of multiple upper or lower extremity muscles. EIM reactance values revealed consistent reductions in the radiculopathy-affected myotomal muscles as compared with those on the unaffected side; the degree of asymmetry was associated strongly with the degree of EMG abnormality (P < 0.001). EIM had a sensitivity of 64.5% and a specificity of 77.0%; in comparison, EMG had a sensitivity of 79.7% but a specificity of 69.7%. These findings support the potential for EIM to serve as a new non-invasive tool to assist in diagnosis of radiculopathy; however, further refinement of the technique is needed for this specific application. Copyright © 2013 Wiley Periodicals, Inc.

  12. Towards high-throughput molecular detection of Plasmodium: new approaches and molecular markers

    PubMed Central

    Steenkeste, Nicolas; Incardona, Sandra; Chy, Sophy; Duval, Linda; Ekala, Marie-Thérèse; Lim, Pharath; Hewitt, Sean; Sochantha, Tho; Socheat, Doung; Rogier, Christophe; Mercereau-Puijalon, Odile; Fandeur, Thierry; Ariey, Frédéric

    2009-01-01

    Background Several strategies are currently deployed in many countries in the tropics to strengthen malaria control toward malaria elimination. To measure the impact of any intervention, there is a need to detect malaria properly. Mostly, decisions still rely on microscopy diagnosis. But sensitive diagnosis tools enabling to deal with a large number of samples are needed. The molecular detection approach offers a much higher sensitivity, and the flexibility to be automated and upgraded. Methods Two new molecular methods were developed: dot18S, a Plasmodium-specific nested PCR based on the 18S rRNA gene followed by dot-blot detection of species by using species-specific probes and CYTB, a Plasmodium-specific nested PCR based on cytochrome b gene followed by species detection using SNP analysis. The results were compared to those obtained with microscopic examination and the "standard" 18S rRNA gene based nested PCR using species specific primers. 337 samples were diagnosed. Results Compared to the microscopy the three molecular methods were more sensitive, greatly increasing the estimated prevalence of Plasmodium infection, including P. malariae and P. ovale. A high rate of mixed infections was uncovered with about one third of the villagers infected with more than one malaria parasite species. Dot18S and CYTB sensitivity outranged the "standard" nested PCR method, CYTB being the most sensitive. As a consequence, compared to the "standard" nested PCR method for the detection of Plasmodium spp., the sensitivity of dot18S and CYTB was respectively 95.3% and 97.3%. Consistent detection of Plasmodium spp. by the three molecular methods was obtained for 83% of tested isolates. Contradictory results were mostly related to detection of Plasmodium malariae and Plasmodium ovale in mixed infections, due to an "all-or-none" detection effect at low-level parasitaemia. Conclusion A large reservoir of asymptomatic infections was uncovered using the molecular methods. Dot18S and CYTB, the new methods reported herein are highly sensitive, allow parasite DNA extraction as well as genus- and species-specific diagnosis of several hundreds of samples, and are amenable to high-throughput scaling up for larger sample sizes. Such methods provide novel information on malaria prevalence and epidemiology and are suited for active malaria detection. The usefulness of such sensitive malaria diagnosis tools, especially in low endemic areas where eradication plans are now on-going, is discussed in this paper. PMID:19402894

  13. Survey Definitions of Gout for Epidemiologic Studies: Comparison With Crystal Identification as the Gold Standard.

    PubMed

    Dalbeth, Nicola; Schumacher, H Ralph; Fransen, Jaap; Neogi, Tuhina; Jansen, Tim L; Brown, Melanie; Louthrenoo, Worawit; Vazquez-Mellado, Janitzia; Eliseev, Maxim; McCarthy, Geraldine; Stamp, Lisa K; Perez-Ruiz, Fernando; Sivera, Francisca; Ea, Hang-Korng; Gerritsen, Martijn; Scire, Carlo A; Cavagna, Lorenzo; Lin, Chingtsai; Chou, Yin-Yi; Tausche, Anne-Kathrin; da Rocha Castelar-Pinheiro, Geraldo; Janssen, Matthijs; Chen, Jiunn-Horng; Cimmino, Marco A; Uhlig, Till; Taylor, William J

    2016-12-01

    To identify the best-performing survey definition of gout from items commonly available in epidemiologic studies. Survey definitions of gout were identified from 34 epidemiologic studies contributing to the Global Urate Genetics Consortium (GUGC) genome-wide association study. Data from the Study for Updated Gout Classification Criteria (SUGAR) were randomly divided into development and test data sets. A data-driven case definition was formed using logistic regression in the development data set. This definition, along with definitions used in GUGC studies and the 2015 American College of Rheumatology (ACR)/European League Against Rheumatism (EULAR) gout classification criteria were applied to the test data set, using monosodium urate crystal identification as the gold standard. For all tested GUGC definitions, the simple definition of "self-report of gout or urate-lowering therapy use" had the best test performance characteristics (sensitivity 82%, specificity 72%). The simple definition had similar performance to a SUGAR data-driven case definition with 5 weighted items: self-report, self-report of doctor diagnosis, colchicine use, urate-lowering therapy use, and hyperuricemia (sensitivity 87%, specificity 70%). Both of these definitions performed better than the 1977 American Rheumatism Association survey criteria (sensitivity 82%, specificity 67%). Of all tested definitions, the 2015 ACR/EULAR criteria had the best performance (sensitivity 92%, specificity 89%). A simple definition of "self-report of gout or urate-lowering therapy use" has the best test performance characteristics of existing definitions that use routinely available data. A more complex combination of features is more sensitive, but still lacks good specificity. If a more accurate case definition is required for a particular study, the 2015 ACR/EULAR gout classification criteria should be considered. © 2016, American College of Rheumatology.

  14. Validation of Smartphone Based Retinal Photography for Diabetic Retinopathy Screening.

    PubMed

    Rajalakshmi, Ramachandran; Arulmalar, Subramanian; Usha, Manoharan; Prathiba, Vijayaraghavan; Kareemuddin, Khaji Syed; Anjana, Ranjit Mohan; Mohan, Viswanathan

    2015-01-01

    To evaluate the sensitivity and specificity of "fundus on phone' (FOP) camera, a smartphone based retinal imaging system, as a screening tool for diabetic retinopathy (DR) detection and DR severity in comparison with 7-standard field digital retinal photography. Single-site, prospective, comparative, instrument validation study. 301 patients (602 eyes) with type 2 diabetes underwent standard seven-field digital fundus photography with both Carl Zeiss fundus camera and indigenous FOP at a tertiary care diabetes centre in South India. Grading of DR was performed by two independent retina specialists using modified Early Treatment of Diabetic Retinopathy Study grading system. Sight threatening DR (STDR) was defined by the presence of proliferative DR(PDR) or diabetic macular edema. The sensitivity, specificity and image quality were assessed. The mean age of the participants was 53.5 ±9.6 years and mean duration of diabetes 12.5±7.3 years. The Zeiss camera showed that 43.9% had non-proliferative DR(NPDR) and 15.3% had PDR while the FOP camera showed that 40.2% had NPDR and 15.3% had PDR. The sensitivity and specificity for detecting any DR by FOP was 92.7% (95%CI 87.8-96.1) and 98.4% (95%CI 94.3-99.8) respectively and the kappa (ĸ) agreement was 0.90 (95%CI-0.85-0.95 p<0.001) while for STDR, the sensitivity was 87.9% (95%CI 83.2-92.9), specificity 94.9% (95%CI 89.7-98.2) and ĸ agreement was 0.80 (95%CI 0.71-0.89 p<0.001), compared to conventional photography. Retinal photography using FOP camera is effective for screening and diagnosis of DR and STDR with high sensitivity and specificity and has substantial agreement with conventional retinal photography.

  15. Diagnosing periprosthetic infection: false-positive intraoperative Gram stains.

    PubMed

    Oethinger, Margret; Warner, Debra K; Schindler, Susan A; Kobayashi, Hideo; Bauer, Thomas W

    2011-04-01

    Intraoperative Gram stains have a reported low sensitivity but high specificity when used to help diagnose periprosthetic infections. In early 2008, we recognized an unexpectedly high frequency of apparent false-positive Gram stains from revision arthroplasties. The purpose of this report is to describe the cause of these false-positive test results. We calculated the sensitivity and specificity of all intraoperative Gram stains submitted from revision arthroplasty cases during a 3-month interval using microbiologic cultures of the same samples as the gold standard. Methods of specimen harvesting, handling, transport, distribution, specimen processing including tissue grinding/macerating, Gram staining, and interpretation were studied. After a test modification, results of specimens were prospectively collected for a second 3-month interval, and the sensitivity and specificity of intraoperative Gram stains were calculated. The retrospective review of 269 Gram stains submitted from revision arthroplasties indicated historic sensitivity and specificity values of 23% and 92%, respectively. Systematic analysis of all steps of the procedure identified Gram-stained but nonviable bacteria in commercial broth reagents used as diluents for maceration of periprosthetic membranes before Gram staining and culture. Polymerase chain reaction and sequencing showed mixed bacterial DNA. Evaluation of 390 specimens after initiating standardized Millipore filtering of diluent fluid revealed a reduced number of positive Gram stains, yielding 9% sensitivity and 99% specificity. Clusters of false-positive Gram stains have been reported in other clinical conditions. They are apparently rare related to diagnosing periprosthetic infections but have severe consequences if used to guide treatment. Even occasional false-positive Gram stains should prompt review of laboratory methods. Our observations implicate dead bacteria in microbiologic reagents as potential sources of false-positive Gram stains.

  16. Computer-automated dementia screening using a touch-tone telephone.

    PubMed

    Mundt, J C; Ferber, K L; Rizzo, M; Greist, J H

    2001-11-12

    This study investigated the sensitivity and specificity of a computer-automated telephone system to evaluate cognitive impairment in elderly callers to identify signs of early dementia. The Clinical Dementia Rating Scale was used to assess 155 subjects aged 56 to 93 years (n = 74, 27, 42, and 12, with a Clinical Dementia Rating Scale score of 0, 0.5, 1, and 2, respectively). These subjects performed a battery of tests administered by an interactive voice response system using standard Touch-Tone telephones. Seventy-four collateral informants also completed an interactive voice response version of the Symptoms of Dementia Screener. Sixteen cognitively impaired subjects were unable to complete the telephone call. Performances on 6 of 8 tasks were significantly influenced by Clinical Dementia Rating Scale status. The mean (SD) call length was 12 minutes 27 seconds (2 minutes 32 seconds). A subsample (n = 116) was analyzed using machine-learning methods, producing a scoring algorithm that combined performances across 4 tasks. Results indicated a potential sensitivity of 82.0% and specificity of 85.5%. The scoring model generalized to a validation subsample (n = 39), producing 85.0% sensitivity and 78.9% specificity. The kappa agreement between predicted and actual group membership was 0.64 (P<.001). Of the 16 subjects unable to complete the call, 11 provided sufficient information to permit us to classify them as impaired. Standard scoring of the interactive voice response-administered Symptoms of Dementia Screener (completed by informants) produced a screening sensitivity of 63.5% and 100% specificity. A lower criterion found a 90.4% sensitivity, without lowering specificity. Computer-automated telephone screening for early dementia using either informant or direct assessment is feasible. Such systems could provide wide-scale, cost-effective screening, education, and referral services to patients and caregivers.

  17. Sensitivity and specificity of the circulating cathodic antigen rapid urine test in the diagnosis of Schistosomiasis mansoni infection and evaluation of morbidity in a low- endemic area in Brazil.

    PubMed

    Ferreira, Fernanda Teixeira; Fidelis, Thiago André; Pereira, Thiago Almeida; Otoni, Alba; Queiroz, Leonardo Campos; Amâncio, Frederico Figueiredo; Antunes, Carlos Maurício; Lambertucci, José Roberto

    2017-01-01

    The Kato-Katz technique is the standard diagnostic test for Schistosoma mansoni infection in rural areas. However, the utility of this method is severely limited by the day-to-day variability in host egg excretion in the stool. In high-transmission areas, the point-of-care circulating cathodic antigen (POC-CCA) urine assay has proven to be a reliable test. However, investigations of the reliability of the POC-CCA assay in low-transmission regions are under way. This study aimed to evaluate the sensitivity and specificity of the POC-CCA assay and the morbidity of schistosomiasis in a low-endemic area in Brazil. Pains City is a low-transmission zone for schistosomiasis. A total of 300 subjects aged 7-76 years were randomly selected for the POC-CCA cassette test. For S. mansoni diagnosis, three stool samples on six slides were compared with one urine sample for each subject. The sensitivity and specificity in the absence of a gold standard were calculated using latent class analysis. Clinical examinations and abdominal ultrasounds were performed in 181 volunteers to evaluate morbidity associated with schistosomiasis. The sensitivity and specificity of the Kato-Katz technique were 25.6% and 94.6%, respectively. By contrast, the sensitivity and specificity of the POC-CCA assay were 68.1% and 72.8%, respectively. Hepatosplenic schistosomiasis was diagnosed in two patients (1.1%). Overall, the POC-CCA urine assay proved to be a useful test for diagnosing S. mansoni in a low-endemic area in Brazil. Severe clinical forms of schistosomiasis can be present even in such low-endemic areas.

  18. Development and validation of a quantitative PCR for rapid and specific detection of California sea lion adenovirus 1 and prevalence in wild and managed populations.

    PubMed

    Cortés-Hinojosa, Galaxia; Gulland, Frances M D; Goldstein, Tracey; Venn-Watson, Stephanie; Rivera, Rebecca; Archer, Linda L; Waltzek, Thomas B; Gray, Gregory C; Wellehan, James F X

    2017-03-01

    California sea lion adenovirus 1 (CSLAdV-1) has been associated with hepatitis and enteritis in several wild and captive populations of diverse pinniped species. Currently available tests have been limited to pan-adenoviral polymerase chain reaction (PCR) followed by sequencing. We present the development of a quantitative probe-hybridization PCR (qPCR) assay for rapid, sensitive, and specific detection of this virus in California sea lions ( Zalophus californianus) and other pinnipeds. This assay did not amplify other mammalian adenoviruses and is able to detect consistently down to 10 viral copies per well. Compared with the gold standard conventional pan-adenovirus PCR/sequencing assay, diagnostic sensitivity and specificity of 100% and 88.2% were found, respectively. The lower diagnostic specificity of this qPCR assay may be the result of the lower limit of detection of this assay compared with the gold standard rather than the result of detection of true false-positives.

  19. Duodenal endoscopic findings and histopathologic confirmation of intestinal lymphangiectasia in dogs.

    PubMed

    Larson, R N; Ginn, J A; Bell, C M; Davis, M J; Foy, D S

    2012-01-01

    The diagnosis of intestinal lymphangiectasia (IL) has been associated with characteristic duodenal mucosal changes. However, the sensitivity and specificity of the endoscopic duodenal mucosal appearance for the diagnosis of IL are not reported. To evaluate the utility of endoscopic images of the duodenum for diagnosis of IL. Endoscopic appearance of the duodenal mucosal might predict histopathologic diagnosis of IL with a high degree of sensitivity and specificity. 51 dogs that underwent upper gastrointestinal (GI) endoscopy and endoscopic biopsies. Retrospective review of images acquired during endoscopy. Dogs were included if adequate biopsies were obtained during upper GI endoscopy and digital images were saved during the procedure. Images were assessed for the presence and severity of IL. Using histopathology as the gold standard, the sensitivity and specificity of endoscopy for diagnosing IL were calculated. Intestinal lymphangiectasia (IL) was diagnosed in 25/51 dogs. Gross endoscopic appearance of the duodenal mucosa had a sensitivity and specificity (95% confidence interval) of 68% (46%, 84%) and 42% (24%, 63%), respectively for diagnosis of IL. Endoscopic images in cases with lymphopenia, hypocholesterolemia, and hypoalbuminemia had a sensitivity of 80%. Endoscopic duodenal mucosa appearance alone lacks specificity and has only a moderate sensitivity for diagnosis of IL. Evaluation of biomarkers associated with PLE improved the sensitivity; however, poor specificity for diagnosis of IL supports the need for histopathologic confirmation. Copyright © 2012 by the American College of Veterinary Internal Medicine.

  20. Sensitivity and specificity: twin goals of proteomics assays. Can they be combined?

    PubMed

    Wilson, Robert

    2013-04-01

    A major ambition of proteomics is the provision of assays that can diagnose disease and monitor therapies. These assays are required to be sensitive and specific for individual proteins, and in most cases to quantify more than one protein in the same sample. The two main technologies currently used for proteomics assays are based on mass spectrometry and panels of affinity molecules such as antibodies. In the first part of this review the most sensitive existing assays based on these technologies are described and compared with the gold standard of ELISA. Analytical sensitivity is defined and related to the limit of detection, and analytical specificity is defined and shown to depend on molecular proofreading steps, similar to those applied in living systems whenever there is a need for high fidelity. It is shown that at present neither mass spectrometry nor panels of affinity molecules offer the necessary combination of sensitivity and specificity required for multiplexed assays. In the second part of this review the growing numbers of assays that use additional proofreading steps to combine sensitivity with specificity are described. These include assays based on proximity ligation and slow off-rate modified aptamers. Finally the review considers what improvements might be possible in the near future, and concludes that further development of proteomics assays incorporating advanced proofreading steps are most likely to provide the necessary combination of sensitivity and specificity, without incurring high development costs.

  1. A new computer program for mass screening of visual defects in preschool children.

    PubMed

    Briscoe, D; Lifshitz, T; Grotman, M; Kushelevsky, A; Vardi, H; Weizman, S; Biedner, B

    1998-04-01

    To test the effectiveness of a PC computer program for detecting vision disorders which could be used by non-trained personnel, and to determine the prevalence of visual impairment in a sample population of preschool children in the city of Beer-Sheba, Israel. 292 preschool children, aged 4-6 years, were examined in the kindergarten setting, using the computer system and "gold standard" tests. Visual acuity and stereopsis were tested and compared using Snellen type symbol charts and random dot stereograms respectively. The sensitivity, specificity, positive predictive value, negative predictive value, and kappa test were evaluated. A computer pseudo Worth four dot test was also performed but could not be compared with the standard Worth four dot test owing to the inability of many children to count. Agreement between computer and gold standard tests was 83% and 97.3% for visual acuity and stereopsis respectively. The sensitivity of the computer stereogram was only 50%, but it had a specificity of 98.9%, whereas the sensitivity and specificity of the visual acuity test were 81.5% and 83% respectively. The positive predictive value of both tests was about 63%. 27.7% of children tested had a visual acuity of 6/12 or less and stereopsis was absent in 28% using standard tests. Impairment of fusion was found in 5% of children using the computer pseudo Worth four dot test. The computer program was found to be stimulating, rapid, and easy to perform. The wide availability of computers in schools and at home allow it to be used as an additional screening tool by non-trained personnel, such as teachers and parents, but it is not a replacement for standard testing.

  2. Detection of vessel wall calcifications in vertebral arteries using susceptibility weighted imaging.

    PubMed

    Adams, Lisa C; Böker, Sarah M; Bender, Yvonne Y; Fallenberg, Eva M; Wagner, Moritz; Liebig, Thomas; Hamm, Bernd; Makowski, Marcus R

    2017-09-01

    Calcification of the brain supplying arteries has been linked to an increased risk for cerebrovascular disease. The purpose of this study was to test the potential of susceptibility weighted MR imaging (SWMR) for the detection of vertebral artery calcifications, based on CT as a reference standard. Four hundred seventy-four patients, who had received head CT and 1.5 T MR scans with SWMR, including the distal vertebral artery, between January 2014 and December 2016, were retrospectively evaluated and 389 patients were included. Sensitivity and specificity for the detection of focal calcifications and intra- and interobserver agreement were calculated for SWMR and standard MRI, using CT as a standard of reference. The diameter of vertebral artery calcifications was used to assess correlations between imaging modalities. Furthermore, the degree of vessel stenosis was determined in 30 patients, who had received an additional angiography. On CT scans, 40 patients showed a total of 52 vertebral artery calcifications. While SWMR reached a sensitivity of 94% (95% CI 84-99%) and a specificity of 97% (95% CI 94-98%), standard MRI yielded a sensitivity of 33% (95% CI 20-46%), and a specificity of 93% (95% CI 90-96%). Linear regression analysis of size measurements confirmed a close correlation between SWMR and CT measurements (R 2  = 0.74, p < 0.001). Compared to standard MRI (ICC = 0.52; CI 0.45-0.59), SWMR showed a higher interobserver agreement for calcification measurements (ICC = 0.84; CI 0.81-0.87). For detection of distal vertebral artery calcifications, SWMR demonstrates a performance comparable to CT and considerably higher than conventional MRI.

  3. Validation of Standardized Questionnaires Evaluating Symptoms of Depression in Rheumatoid Arthritis Patients: Approaches to Screening for a Frequent Yet Underrated Challenge.

    PubMed

    Englbrecht, Matthias; Alten, Rieke; Aringer, Martin; Baerwald, Christoph G; Burkhardt, Harald; Eby, Nancy; Fliedner, Gerhard; Gauger, Bettina; Henkemeier, Ulf; Hofmann, Michael W; Kleinert, Stefan; Kneitz, Christian; Krueger, Klaus; Pohl, Christoph; Roske, Anne-Eve; Schett, Georg; Schmalzing, Marc; Tausche, Anne-Kathrin; Peter Tony, Hans; Wendler, Joerg

    2017-01-01

    To validate standard self-report questionnaires for depression screening in patients with rheumatoid arthritis (RA) and compare these measures to one another and to the Montgomery-Åsberg Depression Rating Scale (MADRS), a standardized structured interview. In 9 clinical centers across Germany, depressive symptomatology was assessed in 262 adult RA patients at baseline (T0) and at 12 ± 2 weeks followup (T1) using the World Health Organization 5-Item Well-Being Index (WHO-5), the Patient Health Questionnaire (PHQ-9), and the Beck Depression Inventory II (BDI-II). The construct validity of these depression questionnaires (using convergent and discriminant validity) was evaluated using Spearman's correlations at both time points. The test-retest reliability of the questionnaires was evaluated in RA patients who had not undergone a psychotherapeutic intervention or received antidepressants between T0 and T1. The sensitivity and the specificity of the questionnaires were calculated using the results of the MADRS, a structured interview, as the gold standard. According to Spearman's correlation coefficients, all questionnaires met convergent validity criteria (ρ > |0.50|), with the BDI-II performing best, while correlations with age and disease activity for all questionnaires met the criteria for discriminant validity (ρ < |0.50|). The only questionnaire to meet the predefined retest reliability criterion (ρ ≥ 0.70) was the BDI-II (r s  = 0.77), which also achieved the best results for both sensitivity and specificity (>80%) when using the MADRS as the gold standard. The BDI-II best met the predefined criteria, and the PHQ-9 met most of the validity criteria, with lower sensitivity and specificity. © 2016, American College of Rheumatology.

  4. Comparison of wheat and rye flour solutions for skin prick testing: a multi-centre study (Stad 1).

    PubMed

    van Kampen, V; Merget, R; Rabstein, S; Sander, I; Bruening, T; Broding, H C; Keller, C; Muesken, H; Overlack, A; Schultze-Werninghaus, G; Walusiak, J; Raulf-Heimsoth, M

    2009-12-01

    Skin prick testing (SPT) is the basic method for diagnosing IgE-mediated allergies. However, skin reactivity is related to the quality of allergen extracts, which are often poorly defined for occupational allergens. To compare wheat and rye flour SPT solutions from different producers. Standardized SPTs were performed in seven allergy centres with wheat and rye flour solutions from four producers in 125 symptomatic bakers. Optimal cut-off levels for weal sizes were assessed with the Youden Index. Comparisons between SPT results of different solutions were made with flour-specific IgE (sIgE) as the gold standard. Sensitivities, specificities, positive and negative predictive values, and test efficiencies were calculated and compared with McNemar and chi(2)-tests. The influence of the choice of the gold standard (sIgE or challenge) test was examined for 95 subjects. Additionally, SPT solutions were analysed for protein and antigen content. The optimal cut-off level for all SPT solutions was a weal size of >or=1.5 mm. While differences between wheat and rye flours were small, differences between producers were important. Variability of sensitivities (0.31-0.96), negative predictive values (0.42-0.91), and test efficiencies (0.54-0.90) were higher than variations of specificities (0.74-1.00) and positive predictive values (0.88-1.00). Similar results were obtained when using challenge test results as the gold standard. Variability could be explained by the different antigen contents of the SPT solutions. There is a wide variability of SPT solutions for wheat and rye flour from different producers, mainly with respect to sensitivities, negative predictive values, and test efficiencies. Improvement and standardization of SPT solutions used for the diagnosis of baker's asthma are highly recommended.

  5. Diagnostic efficacy of microscopy, rapid diagnostic test and polymerase chain reaction for malaria using bayesian latent class analysis.

    PubMed

    Saha, Sreemanti; Narang, Rahul; Deshmukh, Pradeep; Pote, Kiran; Anvikar, Anup; Narang, Pratibha

    2017-01-01

    The diagnostic techniques for malaria are undergoing a change depending on the availability of newer diagnostics and annual parasite index of infection in a particular area. At the country level, guidelines are available for selection of diagnostic tests; however, at the local level, this decision is made based on malaria situation in the area. The tests are evaluated against the gold standard, and if that standard has limitations, it becomes difficult to compare other available tests. Bayesian latent class analysis computes its internal standard rather than using the conventional gold standard and helps comparison of various tests including the conventional gold standard. In a cross-sectional study conducted in a tertiary care hospital setting, we have evaluated smear microscopy, rapid diagnostic test (RDT), and polymerase chain reaction (PCR) for diagnosis of malaria using Bayesian latent class analysis. We found the magnitude of malaria to be 17.7% (95% confidence interval: 12.5%-23.9%) among the study subjects. In the present study, the sensitivity of microscopy was 63%, but it had very high specificity (99.4%). Sensitivity and specificity of RDT and PCR were high with RDT having a marginally higher sensitivity (94% vs. 90%) and specificity (99% vs. 95%). On comparison of likelihood ratios (LRs), RDT had the highest LR for positive test result (175) and the lowest LR for negative test result (0.058) among the three tests. In settings like ours conventional smear microscopy may be replaced with RDT and as we move toward elimination and facilities become available PCR may be roped into detect cases with lower parasitaemia.

  6. The Use of Bacterial Repair Endonucleases in the Comet Assay.

    PubMed

    Collins, Andrew R

    2017-01-01

    The comet assay is a sensitive electrophoretic method for measuring DNA breaks at the level of single cells, used widely in genotoxicity experiments, in biomonitoring, and in fundamental research. Its sensitivity and range of application are increased by the incorporation of an extra step, after lysis of agarose-embedded cells, in which the DNA is digested with lesion-specific endonucleases (DNA repair enzymes of bacterial or phage origin). Enzymes with specificity for oxidized purines, oxidized pyrimidines, alkylated bases, UV-induced cyclobutane pyrimidine dimers, and misincorporated uracil have been employed. The additional enzyme-sensitive sites, over and above the strand breaks detected in the standard comet assay, give a quantitative estimate of the number of specific lesions present in the cells.

  7. Nested PCR for specific diagnosis of Taenia solium taeniasis.

    PubMed

    Mayta, Holger; Gilman, Robert H; Prendergast, Emily; Castillo, Janeth P; Tinoco, Yeny O; Garcia, Hector H; Gonzalez, Armando E; Sterling, Charles R

    2008-01-01

    Taeniasis due to Taenia solium is a disease with important public health consequences, since the larval stage is not exclusive to the animal intermediate, the pig, but also infects humans, causing neurocysticercosis. Early diagnosis and treatment of T. solium tapeworm carriers is important to prevent human cysticercosis. Current diagnosis based on microscopic observation of eggs lacks both sensitivity and specificity. In the present study, a nested-PCR assay targeting the Tso31 gene was developed for the specific diagnosis of taeniasis due to T. solium. Initial specificity and sensitivity testing was performed using stored known T. solium-positive and -negative samples. The assay was further analyzed under field conditions by conducting a case-control study of pretreatment stool samples collected from a population in an area of endemicity. Using the archived samples, the assay showed 97% (31/32) sensitivity and 100% (123/123) specificity. Under field conditions, the assay had 100% sensitivity and specificity using microscopy/enzyme-linked immunosorbent assay coproantigen testing as the gold standards. The Tso31 nested PCR described here might be a useful tool for the early diagnosis and prevention of taeniasis/cysticercosis.

  8. Strain-specific variations in cation content and transport in mouse erythrocytes

    PubMed Central

    Rivera, Alicia; Zee, Robert Y. L.; Alper, Seth L.; Peters, Luanne L.

    2013-01-01

    Studies of ion transport pathophysiology in hematological disorders and tests of possible new therapeutic agents for these disorders have been carried out in various mouse models because of close functional similarities between mouse and human red cells. We have explored strain-specific differences in erythrocyte membrane physiology in 10 inbred mouse strains by determining erythrocyte contents of Na+, K+, and Mg2+, and erythrocyte transport of ions via the ouabain-sensitive Na-K pump, the amiloride-sensitive Na-H exchanger (NHE1), the volume and chloride-dependent K-Cl cotransporter (KCC), and the charybdotoxin-sensitive Gardos channel (KCNN4). Our data reveal substantial strain-specific and sex-specific differences in both ion content and trans-membrane ion transport in mouse erythrocytes. These differences demonstrate the feasibility of identifying specific quantitative trait loci for erythroid ion transport and content in genetically standardized inbred mouse strains. PMID:23482811

  9. Strain-specific variations in cation content and transport in mouse erythrocytes.

    PubMed

    Rivera, Alicia; Zee, Robert Y L; Alper, Seth L; Peters, Luanne L; Brugnara, Carlo

    2013-05-01

    Studies of ion transport pathophysiology in hematological disorders and tests of possible new therapeutic agents for these disorders have been carried out in various mouse models because of close functional similarities between mouse and human red cells. We have explored strain-specific differences in erythrocyte membrane physiology in 10 inbred mouse strains by determining erythrocyte contents of Na(+), K(+), and Mg(2+), and erythrocyte transport of ions via the ouabain-sensitive Na-K pump, the amiloride-sensitive Na-H exchanger (NHE1), the volume and chloride-dependent K-Cl cotransporter (KCC), and the charybdotoxin-sensitive Gardos channel (KCNN4). Our data reveal substantial strain-specific and sex-specific differences in both ion content and trans-membrane ion transport in mouse erythrocytes. These differences demonstrate the feasibility of identifying specific quantitative trait loci for erythroid ion transport and content in genetically standardized inbred mouse strains.

  10. Validity of self-reported stroke in elderly African Americans, Caribbean Hispanics, and Whites.

    PubMed

    Reitz, Christiane; Schupf, Nicole; Luchsinger, José A; Brickman, Adam M; Manly, Jennifer J; Andrews, Howard; Tang, Ming X; DeCarli, Charles; Brown, Truman R; Mayeux, Richard

    2009-07-01

    The validity of a self-reported stroke remains inconclusive. To validate the diagnosis of self-reported stroke using stroke identified by magnetic resonance imaging (MRI) as the standard. Community-based cohort study of nondemented, ethnically diverse elderly persons in northern Manhattan. High-resolution quantitative MRIs were acquired for 717 participants without dementia. Sensitivity and specificity of stroke by self-report were examined using cross-sectional analyses and the chi(2) test. Putative relationships between factors potentially influencing the reporting of stroke, including memory performance, cognitive function, and vascular risk factors, were assessed using logistic regression models. Subsequently, all analyses were repeated, stratified by age, sex, ethnic group, and level of education. In analyses of the whole sample, sensitivity of stroke self-report for a diagnosis of stroke on MRI was 32.4%, and specificity was 78.9%. In analyses stratified by median age (80.1 years), the validity between reported stroke and detection of stroke on MRI was significantly better in the younger than the older age group (for all vascular territories: sensitivity and specificity, 36.7% and 81.3% vs 27.6% and 26.2%; P = .02). Impaired memory, cognitive skills, or language ability and the presence of hypertension or myocardial infarction were associated with higher rates of false-negative results. Using brain MRI as the standard, specificity and sensitivity of stroke self-report are low. Accuracy of self-report is influenced by age, presence of vascular disease, and cognitive function. In stroke research, sensitive neuroimaging techniques rather than stroke self-report should be used to determine stroke history.

  11. Preliminary development of an ultrabrief two-item bedside test for delirium.

    PubMed

    Fick, Donna M; Inouye, Sharon K; Guess, Jamey; Ngo, Long H; Jones, Richard N; Saczynski, Jane S; Marcantonio, Edward R

    2015-10-01

    Delirium is common, morbid, and costly, yet is greatly under-recognized among hospitalized older adults. To identify the best single and pair of mental status test items that predict the presence of delirium. Diagnostic test evaluation study that enrolled medicine inpatients aged 75 years or older at an academic medical center. Patients underwent a clinical reference standard assessment involving a patient interview, medical record review, and interviews with family members and nurses to determine the presence or absence of Diagnostic and Statistical Manual of Mental Disorders, 4th Edition defined delirium. Participants also underwent the three-dimensional Confusion Assessment Method (3D-CAM), a brief, validated assessment for delirium. Individual items and pairs of items from the 3D-CAM were evaluated to determine sensitivity and specificity relative to the reference standard delirium diagnosis. Of the 201 participants (mean age 84 years, 62% female), 42 (21%) had delirium based on the clinical reference standard. The single item with the best test characteristics was "months of the year backwards" with a sensitivity of 83% (95% confidence interval [CI]: 69%-93%) and specificity of 69% (95% CI: 61%-76%). The best 2-item screen was the combination of "months of the year backwards" and "what is the day of the week?" with a sensitivity of 93% (95% CI: 81%-99%) and specificity of 64% (95% CI: 56%-70%). We identified a single item with >80% and pair of items with >90% sensitivity for delirium. If validated prospectively, these items will serve as an initial innovative screening step for delirium identification in hospitalized older adults. © 2015 Society of Hospital Medicine.

  12. Development of a genus-specific next generation sequencing approach for sensitive and quantitative determination of the Legionella microbiome in freshwater systems.

    PubMed

    Pereira, Rui P A; Peplies, Jörg; Brettar, Ingrid; Höfle, Manfred G

    2017-03-31

    Next Generation Sequencing (NGS) has revolutionized the analysis of natural and man-made microbial communities by using universal primers for bacteria in a PCR based approach targeting the 16S rRNA gene. In our study we narrowed primer specificity to a single, monophyletic genus because for many questions in microbiology only a specific part of the whole microbiome is of interest. We have chosen the genus Legionella, comprising more than 20 pathogenic species, due to its high relevance for water-based respiratory infections. A new NGS-based approach was designed by sequencing 16S rRNA gene amplicons specific for the genus Legionella using the Illumina MiSeq technology. This approach was validated and applied to a set of representative freshwater samples. Our results revealed that the generated libraries presented a low average raw error rate per base (<0.5%); and substantiated the use of high-fidelity enzymes, such as KAPA HiFi, for increased sequence accuracy and quality. The approach also showed high in situ specificity (>95%) and very good repeatability. Only in samples in which the gammabacterial clade SAR86 was present more than 1% non-Legionella sequences were observed. Next-generation sequencing read counts did not reveal considerable amplification/sequencing biases and showed a sensitive as well as precise quantification of L. pneumophila along a dilution range using a spiked-in, certified genome standard. The genome standard and a mock community consisting of six different Legionella species demonstrated that the developed NGS approach was quantitative and specific at the level of individual species, including L. pneumophila. The sensitivity of our genus-specific approach was at least one order of magnitude higher compared to the universal NGS approach. Comparison of quantification by real-time PCR showed consistency with the NGS data. Overall, our NGS approach can determine the quantitative abundances of Legionella species, i. e. the complete Legionella microbiome, without the need for species-specific primers. The developed NGS approach provides a new molecular surveillance tool to monitor all Legionella species in qualitative and quantitative terms if a spiked-in genome standard is used to calibrate the method. Overall, the genus-specific NGS approach opens up a new avenue to massive parallel diagnostics in a quantitative, specific and sensitive way.

  13. High Sensitivity and Specificity of Clinical Microscopy in Rural Health Facilities in Western Kenya Under an External Quality Assurance Program

    PubMed Central

    Wafula, Rebeccah; Sang, Edna; Cheruiyot, Olympia; Aboto, Angeline; Menya, Diana; O'Meara, Wendy Prudhomme

    2014-01-01

    Microscopic diagnosis of malaria is a well-established and inexpensive technique that has the potential to provide accurate diagnosis of malaria infection. However, it requires both training and experience. Although it is considered the gold standard in research settings, the sensitivity and specificity of routine microscopy for clinical care in the primary care setting has been reported to be unacceptably low. We established a monthly external quality assurance program to monitor the performance of clinical microscopy in 17 rural health centers in western Kenya. The average sensitivity over the 12-month period was 96% and the average specificity was 88%. We identified specific contextual factors that contributed to inadequate performance. Maintaining high-quality malaria diagnosis in high-volume, resource-constrained health facilities is possible. PMID:24935953

  14. Molecular Diagnostic Testing for Aspergillus

    PubMed Central

    Powers-Fletcher, Margaret V.

    2016-01-01

    The direct detection of Aspergillus nucleic acid in clinical specimens has the potential to improve the diagnosis of aspergillosis by offering more rapid and sensitive identification of invasive infections than is possible with traditional techniques, such as culture or histopathology. Molecular tests for Aspergillus have been limited historically by lack of standardization and variable sensitivities and specificities. Recent efforts have been directed at addressing these limitations and optimizing assay performance using a variety of specimen types. This review provides a summary of standardization efforts and outlines the complexities of molecular testing for Aspergillus in clinical mycology. PMID:27487954

  15. Diagnostic Accuracy of Memory Measures in Alzheimer’s Dementia and Mild Cognitive Impairment: a Systematic Review and Meta-Analysis

    PubMed Central

    Weissberger, Gali H.; Strong, Jessica V.; Stefanidis, Kayla B.; Summers, Mathew J.; Bondi, Mark W.; Stricker, Nikki H.

    2018-01-01

    With an increasing focus on biomarkers in dementia research, illustrating the role of neuropsychological assessment in detecting mild cognitive impairment (MCI) and Alzheimer’s dementia (AD) is important. This systematic review and meta-analysis, conducted in accordance with PRISMA (Preferred Reporting Items for Systematic reviews and Meta-Analyses) standards, summarizes the sensitivity and specificity of memory measures in individuals with MCI and AD. Both meta-analytic and qualitative examination of AD versus healthy control (HC) studies (n = 47) revealed generally high sensitivity and specificity (≥ 80% for AD comparisons) for measures of immediate (sensitivity = 87%, specificity = 88%) and delayed memory (sensitivity = 89%, specificity = 89%), especially those involving word-list recall. Examination of MCI versus HC studies (n = 38) revealed generally lower diagnostic accuracy for both immediate (sensitivity = 72%, specificity = 81%) and delayed memory (sensitivity = 75%, specificity = 81%). Measures that differentiated AD from other conditions (n = 10 studies) yielded mixed results, with generally high sensitivity in the context of low or variable specificity. Results confirm that memory measures have high diagnostic accuracy for identification of AD, are promising but require further refinement for identification of MCI, and provide support for ongoing investigation of neuropsychological assessment as a cognitive biomarker of preclinical AD. Emphasizing diagnostic test accuracy statistics over null hypothesis testing in future studies will promote the ongoing use of neuropsychological tests as Alzheimer’s disease research and clinical criteria increasingly rely upon cerebrospinal fluid (CSF) and neuroimaging biomarkers. PMID:28940127

  16. A guide to unclassified sensitive information protection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Donahue, S.C.

    1996-11-14

    This document is a reference guide for CIC-Division employees who lead or participate in projects that use and/or produce unclassified sensitive information. It is intended for use on a case by case basis to develop project specific sensitive information handling procedures and standards. It contains criteria for identifying sensitive information and determining levels of sensitivity, and describes cost effective measures for protecting various levels of sensitive information. The goal of this document is to help establish good business practices that benefit both the Laboratory and its customers. Division personnel are encouraged to apply these guidelines.

  17. Sensitivity, Specificity, and Public-Health Utility of Clinical Case Definitions Based on the Signs and Symptoms of Cholera in Africa.

    PubMed

    Nadri, Johara; Sauvageot, Delphine; Njanpop-Lafourcade, Berthe-Marie; Baltazar, Cynthia S; Banla Kere, Abiba; Bwire, Godfrey; Coulibaly, Daouda; Kacou N'Douba, Adele; Kagirita, Atek; Keita, Sakoba; Koivogui, Lamine; Landoh, Dadja E; Langa, Jose P; Miwanda, Berthe N; Mutombo Ndongala, Guy; Mwakapeje, Elibariki R; Mwambeta, Jacob L; Mengel, Martin A; Gessner, Bradford D

    2018-04-01

    During 2014, Africa reported more than half of the global suspected cholera cases. Based on the data collected from seven countries in the African Cholera Surveillance Network (Africhol), we assessed the sensitivity, specificity, and positive and negative predictive values of clinical cholera case definitions, including that recommended by the World Health Organization (WHO) using culture confirmation as the gold standard. The study was designed to assess results in real-world field situations in settings with recent cholera outbreaks or endemicity. From June 2011 to July 2015, a total of 5,084 persons with suspected cholera were tested for Vibrio cholerae in seven different countries of which 35.7% had culture confirmation. For all countries combined, the WHO case definition had a sensitivity = 92.7%, specificity = 8.1%, positive predictive value = 36.1%, and negative predictive value = 66.6%. Adding dehydration, vomiting, or rice water stools to the case definition could increase the specificity without a substantial decrease in sensitivity. Future studies could further refine our findings primarily by using more sensitive methods for cholera confirmation.

  18. Sensitivity and specificity of obesity diagnosis in pediatric ambulatory care in the United States.

    PubMed

    Walsh, Carolyn O; Milliren, Carly E; Feldman, Henry A; Taveras, Elsie M

    2013-09-01

    We examined the sensitivity and specificity of an obesity diagnosis in a nationally representative sample of pediatric outpatient visits. We used the 2005 to 2009 National Ambulatory Medical Care and National Hospital Ambulatory Medical Care surveys. We included visits with children 2 to 18 years, yielding a sample of 48 145 database visits. We determined 3 methods of identifying obesity: documented body mass index (BMI) ≥95th percentile; International Classification of Diseases, Ninth Revision (ICD-9) code; and positive answer to the question, "Does the patient now have obesity?" Using BMI as the gold standard, we calculated the sensitivity and specificity of a clinical obesity diagnosis. Among the 19.5% of children who were obese by BMI, 7.0% had an ICD-9 code and 15.2% had a positive response to questioning. The sensitivity of an obesity diagnosis was 15.4%, and the specificity was 99.2%. The sensitivity of the obesity diagnosis in pediatric ambulatory visits is low. Efforts are needed to increase identification of obese children.

  19. Validity of self-assessment in a quality improvement collaborative in Ecuador.

    PubMed

    Hermida, Jorge; Broughton, Edward I; Miller Franco, Lynne

    2011-12-01

    Health care quality improvement (QI) efforts commonly use self-assessment to measure compliance with quality standards. This study investigates the validity of self-assessment of quality indicators. Cross sectional. A maternal and newborn care improvement collaborative intervention conducted in health facilities in Ecuador in 2005. Four external evaluators were trained in abstracting medical records to calculate six indicators reflecting compliance with treatment standards. About 30 medical records per month were examined at 12 participating health facilities for a total of 1875 records. The same records had already been reviewed by QI teams at these facilities (self-assessment). Overall compliance, agreement (using the Kappa statistic), sensitivity and specificity were analyzed. We also examined patterns of disagreement and the effect of facility characteristics on levels of agreement. External evaluators reported compliance of 69-90%, while self-assessors reported 71-92%, with raw agreement of 71-95% and Kappa statistics ranging from fair to almost perfect agreement. Considering external evaluators as the gold standard, sensitivity of self-assessment ranged from 90 to 99% and specificity from 48 to 86%. Simpler indicators had fewer disagreements. When disagreements occurred between self-assessment and external valuators, the former tended to report more positive findings in five of six indicators, but this tendency was not of a magnitude to change program actions. Team leadership, understanding of the tools and facility size had no overall impact on the level of agreement. When compared with external evaluation (gold standard), self-assessment was found to be sufficiently valid for tracking QI team performance. Sensitivity was generally higher than specificity. Simplifying indicators may improve validity.

  20. Performance of a time-resolved fluorescence immunoassay for measuring varicella-zoster virus immunoglobulin G levels in adults and comparison with commercial enzyme immunoassays and Merck glycoprotein enzyme immunoassay.

    PubMed

    Maple, P A C; Gray, J; Breuer, J; Kafatos, G; Parker, S; Brown, D

    2006-02-01

    Highly sensitive and specific, quantitative assays are needed to detect varicella-zoster virus (VZV) immunoglobulin G in human sera, particularly for determining immune status and response following vaccination. A time-resolved fluorescence immunoassay (TRFIA) has been developed, and its performance was compared to that of two commercial enzyme immunoassays (EIAs) and Merck glycoprotein EIA (gpEIA). The TRFIA had equivalent sensitivity (97.8%) and high specificity (93.5%) in relation to gpEIA. A commercial (Behring) EIA compared favorably with TRFIA in terms of sensitivity (98.4%) but had lower specificity (80.7%). Another commercial EIA (Diamedix) had high specificity (97.1%) but low sensitivity (76.4%) compared to TRFIA if equivocal test results were treated as negative for VZV antibody. A novel feature of the TRFIA was that the cutoff was generated using population mixture modeling and was expressed in mIU/ml, as the assay was calibrated using the British standard VZV antibody.

  1. Comparison of TB-LAMP, GeneXpert MTB/RIF and culture for diagnosis of pulmonary tuberculosis in The Gambia.

    PubMed

    Bojang, Adama L; Mendy, Francis S; Tientcheu, Leopold D; Otu, Jacob; Antonio, Martin; Kampmann, Beate; Agbla, Schadrac; Sutherland, Jayne S

    2016-03-01

    Diagnosis of tuberculosis (TB) remains difficult, particularly in resource-limited settings. The development of nucleic acid-based tests for detection of Mycobacterium tuberculosis complex (MTBC) has significantly increased sensitivity compared to conventional smear microscopy and provides results within a matter of hours compared to weeks for the current gold-standard, liquid culture. In this study we performed side-by-side comparison of mycobacterial detection assays on sputum samples from 285 subjects presenting with symptoms suggestive of TB in The Gambia and a cross-sectional cohort of 156 confirmed TB patients with a median of 2 months of treatment. A novel assay, Loop-Mediated Amplification test for TB (TB-LAMP), was compared to smear microscopy, MGIT culture and GeneXpert MTB/RIF for all samples. When culture was used as the reference standard, we found an overall sensitivity for TB-LAMP of 99% (95% CI: 94.5-99.8) and specificity of 94% (95% CI: 89.3-96.7). When latent class analysis was performed, TB-LAMP had 98.6% (95% CI: 95.9-100) sensitivity and 99% (95% CI: 98.2-100) specificity compared to 91.1% (95% CI: 86.1-96) sensitivity and 100% (95% CI: 98.2-100) specificity for MGIT culture. GeneXpert had the highest sensitivity 99.1% (95% CI: 97.1-100) but the lowest specificity 96% (95% CI: 92.6-98.3). Both TB-LAMP and GeneXpert showed high sensitivity and specificity regardless of age or strain of infection. Our findings show the diagnostic utility of both GeneXpert and TB-LAMP in The Gambia. Whilst TB-LAMP requires less infrastructure, it is unable to detect drug-resistant patterns and therefore would be most suitable as a screening test for new TB cases in peripheral health clinics. Copyright © 2015 The British Infection Association. Published by Elsevier Ltd. All rights reserved.

  2. Universal absolute quantification of biomolecules using element mass spectrometry and generic standards.

    PubMed

    Calderón-Celis, Francisco; Sanz-Medel, Alfredo; Encinar, Jorge Ruiz

    2018-01-23

    We present a novel and highly sensitive ICP-MS approach for absolute quantification of all important target biomolecule containing P, S, Se, As, Br, and/or I (e.g., proteins and phosphoproteins, metabolites, pesticides, drugs), under the same simple instrumental conditions and without requiring any specific and/or isotopically enriched standard.

  3. Bivariate random-effects meta-analysis models for diagnostic test accuracy studies using arcsine-based transformations.

    PubMed

    Negeri, Zelalem F; Shaikh, Mateen; Beyene, Joseph

    2018-05-11

    Diagnostic or screening tests are widely used in medical fields to classify patients according to their disease status. Several statistical models for meta-analysis of diagnostic test accuracy studies have been developed to synthesize test sensitivity and specificity of a diagnostic test of interest. Because of the correlation between test sensitivity and specificity, modeling the two measures using a bivariate model is recommended. In this paper, we extend the current standard bivariate linear mixed model (LMM) by proposing two variance-stabilizing transformations: the arcsine square root and the Freeman-Tukey double arcsine transformation. We compared the performance of the proposed methods with the standard method through simulations using several performance measures. The simulation results showed that our proposed methods performed better than the standard LMM in terms of bias, root mean square error, and coverage probability in most of the scenarios, even when data were generated assuming the standard LMM. We also illustrated the methods using two real data sets. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Field evaluation of a rapid, visually-read colloidal dye immunofiltration assay for Schistosoma japonicum for screening in areas of low transmission.

    PubMed Central

    Xiao, Xiang; Wang, Tianping; Ye, Hongzhuan; Qiang, Guangxiang; Wei, Haiming; Tian, Zhigang

    2005-01-01

    OBJECTIVE: To determine the validity of a recently developed rapid test--a colloidal dye immunofiltration assay (CDIFA)--used by health workers in field settings to identify villagers infected with Schistosoma japonicum. METHODS: Health workers in the field used CDIFA to test samples from 1553 villagers in two areas of low endemicity and an area where S. japonicum was not endemic in Anhui, China. All the samples were then tested in the laboratory by laboratory staff using a standard parasitological method (Kato-Katz), an indirect haemagglutination assay (IHA), and CDIFA. The results of CDIFA performed by health workers were compared with those obtained by Kato-Katz and IHA. FINDINGS: Concordance between the results of CDIFA performed in field settings and in the laboratory was high (kappa index, 0.95; 95% confidence interval, 0.93-0.97). When Kato-Katz was used as the reference test, the overall sensitivity and specificity of CDIFA were 98.5% and 83.6%, respectively in the two villages in areas of low endemicity, while the specificity was 99.8% in the nonendemic village. Compared with IHA, the overall specificity and sensitivity of CDIFA were greater than 99% and 96%, respectively. With the combination of Kato-Katz and IHA as the reference standard, CDIFA had a sensitivity of 95.8% and a specificity of 99.5%, and an accuracy of 98.6% in the two areas of low endemicity. CONCLUSION: CDIFA is a specific, sensitive, and reliable test that can be used for rapid screening for schistosomiasis by health workers in field settings. PMID:16175827

  5. Accuracy of ultrasound versus computed tomography urogram in detecting urinary tract calculi.

    PubMed

    Salinawati, B; Hing, E Y; Fam, X I; Zulfiqar, M A

    2015-08-01

    To determine the (i) sensitivity and specificity of ultrasound (USG) in the detection of urinary tract calculi, (ii) size of renal calculi detected on USG, and (iii) size of renal calculi not seen on USG but detected on computed tomography urogram (CTU). A total of 201 patients' USG and CTU were compared retrospectively for the presence of calculi. Sensitivity, specificity, accuracy, positive predictive value and negative predictive value of USG were calculated with CTU as the gold standard. From the 201 sets of data collected, 59 calculi were detected on both USG and CTU. The sensitivity and specificity of renal calculi detection on USG were 53% and 85% respectively. The mean size of the renal calculus detected on USG was 7.6 mm ± 4.1 mm and the mean size of the renal calculus not visualised on USG but detected on CTU was 4 mm ± 2.4 mm. The sensitivity and specificity of ureteric calculi detection on USG were 12% and 97% respectively. The sensitivity and specificity of urinary bladder calculi detection on USG were 20% and 100% respectively. This study showed that the accuracy of US in detecting renal, ureteric and urinary bladder calculi were 67%, 80% and 98% respectively.

  6. Sensitivity and Specificity of Histoplasma Antigen Detection by Enzyme Immunoassay.

    PubMed

    Cunningham, Lauren; Cook, Audrey; Hanzlicek, Andrew; Harkin, Kenneth; Wheat, Joseph; Goad, Carla; Kirsch, Emily

    2015-01-01

    The objective of this study was to evaluate the sensitivity and specificity of an antigen enzyme immunoassay (EIA) on urine samples for the diagnosis of histoplasmosis in dogs. This retrospective medical records review included canine cases with urine samples submitted for Histoplasma EIA antigen assay between 2007 and 2011 from three veterinary institutions. Cases for which urine samples were submitted for Histoplasma antigen testing were reviewed and compared to the gold standard of finding Histoplasma organisms or an alternative diagnosis on cytology or histopathology. Sensitivity, specificity, negative predictive value, positive predictive value, and the kappa coefficient and associated confidence interval were calculated for the EIA-based Histoplasma antigen assay. Sixty cases met the inclusion criteria. Seventeen cases were considered true positives based on identification of the organism, and 41 cases were considered true negatives with an alternative definitive diagnosis. Two cases were considered false negatives, and there were no false positives. Sensitivity was 89.47% and the negative predictive value was 95.35%. Specificity and the positive predictive value were both 100%. The kappa coefficient was 0.9207 (95% confidence interval, 0.8131-1). The Histoplasma antigen EIA test demonstrated high specificity and sensitivity for the diagnosis of histoplasmosis in dogs.

  7. Sensitivity and specificity of optical coherence tomography angiography (OCT-A) for detection of choroidal neovascularization in real-life practice and varying retinal expertise level.

    PubMed

    Souedan, Vaël; Souied, Eric H; Caillaux, Violaine; Miere, Alexandra; Ameen, Ala El; Blanco-Garavito, Rocio

    2017-05-25

    To evaluate the diagnostic accuracy of OCT angiography (OCT-A) detecting or predicting choroidal neovascularization (CNV), by ophthalmologists of disparate degrees of skills in retinal diseases, using spectral domain optical coherence tomography (SD-OCT) and fluorescein angiography (FA) as a standard reference. Retrospective observational case series. Patient presenting maculopathy and complete imaging were included. FA, SD-OCT, OCT-A and FA coupled to SD-OCT images were graded independently for presence or absence of CNV by ophthalmologists with varying expertise levels. Overall sensitivity of OCT-A was 85.62% (95% CI 79.04-90.76%) and specificity was 81.51% (95% CI 73.36-88.03). Sensitivity of FA was 74.51% (95% CI 66.84-81.20), and specificity was 82.35% (95% CI 74.30-88.73). Sensitivity of FA + SD-OCT was 92.72% (95% CI 87.34-96.30), and specificity was 90.91% (95% CI 84.31-95.37). OCT-A has good sensitivity and specificity for the detection of CNV in all expertise level groups. OCT-A may soon become a routine tool for CNV diagnosis and follow-up.

  8. Identification of genus Acinetobacter: Standardization of in-house PCR and its comparison with conventional phenotypic methods.

    PubMed

    Kulkarni, Sughosh S; Madalgi, Radhika; Ajantha, Ganavalli S; Kulkarni, Raghavendra D

    2017-01-01

    Acinetobacter is grouped under nonfermenting Gram-negative bacilli. It is increasingly isolated from pathological samples. The ability of this genus to acquire drug resistance and spread in the hospital settings is posing a grave problem in healthcare. Specific treatment protocols are advocated for Acinetobacter infections. Hence, rapid identification and drug susceptibility profiling are critical in the management of these infections. To standardize an in-house polymerase chain reaction (PCR) for identification of genus Acinetobacter and to compare PCR with two protocols for its phenotypic identification. A total of 96 clinical isolates of Acinetobacter were included in the study. An in-house PCR for genus level identification of Acinetobacter was standardized. All the isolates were phenotypically identified by two protocols. The results of PCR and phenotypic identification protocols were compared. The in-house PCR standardized was highly sensitive and specific for the genus Acinetobacter . There was 100% agreement between the phenotypic and molecular identification of the genus. The preliminary identification tests routinely used in clinical laboratories were also in complete agreement with phenotypic and molecular identification. The in-house PCR for genus level identification is specific and sensitive. However, it may not be essential for routine identification as the preliminary phenotypic identification tests used in the clinical laboratory reliably identify the genus Acinetobacter .

  9. Schistosoma real-time PCR as diagnostic tool for international travellers and migrants.

    PubMed

    Cnops, Lieselotte; Tannich, Egbert; Polman, Katja; Clerinx, Jan; Van Esbroeck, Marjan

    2012-10-01

    To evaluate the use of a genus-specific PCR that combines high sensitivity with the detection of different Schistosoma species for diagnosis in international travellers and migrants in comparison to standard microscopy. The genus-specific real-time PCR was developed to target the 28S ribosomal RNA gene of the major human Schistosoma species. It was validated for analytical specificity and reproducibility and demonstrated an analytical sensitivity of 0.2 eggs per gram of faeces. Its diagnostic performance was further evaluated on 152 faecal, 32 urine and 38 serum samples from patients presenting at the outpatient clinic of the Institute of Tropical Medicine in Antwerp (Belgium). We detected Schistosoma DNA in 76 faecal (50.0%) and five urine (15.6%) samples of which, respectively, nine and one were not detected by standard microscopy. Only two of the 38 serum samples of patients with confirmed schistosomiasis were positive with the presently developed PCR. Sequence analysis on positive faecal samples allowed identification of the Schistosoma species complex. The real-time PCR is highly sensitive and may offer added value in diagnosing imported schistosomiasis. The genus-specific PCR can detect all schistosome species that are infectious to humans and performs very well with faeces and urine, but not in serum. © 2012 Blackwell Publishing Ltd.

  10. Estimation of infection prevalence and sensitivity in a stratified two-stage sampling design employing highly specific diagnostic tests when there is no gold standard.

    PubMed

    Miller, Ezer; Huppert, Amit; Novikov, Ilya; Warburg, Alon; Hailu, Asrat; Abbasi, Ibrahim; Freedman, Laurence S

    2015-11-10

    In this work, we describe a two-stage sampling design to estimate the infection prevalence in a population. In the first stage, an imperfect diagnostic test was performed on a random sample of the population. In the second stage, a different imperfect test was performed in a stratified random sample of the first sample. To estimate infection prevalence, we assumed conditional independence between the diagnostic tests and develop method of moments estimators based on expectations of the proportions of people with positive and negative results on both tests that are functions of the tests' sensitivity, specificity, and the infection prevalence. A closed-form solution of the estimating equations was obtained assuming a specificity of 100% for both tests. We applied our method to estimate the infection prevalence of visceral leishmaniasis according to two quantitative polymerase chain reaction tests performed on blood samples taken from 4756 patients in northern Ethiopia. The sensitivities of the tests were also estimated, as well as the standard errors of all estimates, using a parametric bootstrap. We also examined the impact of departures from our assumptions of 100% specificity and conditional independence on the estimated prevalence. Copyright © 2015 John Wiley & Sons, Ltd.

  11. On the Validity and Sensitivity of the Phonics Screening Check: Erratum and Further Analysis

    ERIC Educational Resources Information Center

    Gilchrist, James M.; Snowling, Margaret J.

    2018-01-01

    Duff, Mengoni, Bailey and Snowling ("Journal of Research in Reading," 38: 109-123; 2015) evaluated the sensitivity and specificity of the phonics screening check against two reference standards. This report aims to correct a minor data error in the original article and to present further analysis of the data. The methods used are…

  12. Video-game epilepsy: a European study.

    PubMed

    Kasteleijn-Nolst Trenité, D G; da Silva, A M; Ricci, S; Binnie, C D; Rubboli, G; Tassinari, C A; Segers, J P

    1999-01-01

    With the introduction of Nintendo video-games on a large scale, reports of children having seizures while playing suggested a possible specific, provocative factor. Although 50% of the photosensitive patients are also sensitive to a 50-Hz television, nonphotosensitive patients with a history of video-game seizures were described as well. The question arises whether this is a mere coincidence, provoked by fatigue and stress, is related to the reaction to the television screen itself, or depends on the movement and color of the pictures of this specific game. A European study was performed in four countries and five sites. All patients were selected because of a history of television, video- or computer-game seizures, with a history of sun-light-, discotheque-, or black and white pattern-evoked seizures, or were already known to be sensitive to intermittent photic stimulation. A total of 387 patients were investigated; 220 (75%) were female and 214 (55%) of those were < 18 years of age. After a routine examination, intermittent photic, pattern, and television stimulation were performed in a standardized way. The patients were investigated with Super Mario World and a standard relatively nonprovocative TV program, both on a 50- and 100-Hz television. Regardless of the distance, Super Mario World proved to be more provocative than the standard program (Wilcoxon, p < 0.05). Eighty-five percent showed epileptiform discharges evoked by intermittent photic stimulation. Forty-five percent of patients were 50-Hz television sensitive and 26% were 100-Hz television sensitive. Pattern sensitivity was found in 28% of patients. The patients, referred because of a television, video- or computer-game seizure, were significantly more sensitive to pattern and to the 50-Hz television (chi square, p < 0.001). More patients are sensitive when playing Super Mario, compared with the standard program (Wilcoxon, p = 0.001) and more sensitive with playing versus viewing (p = 0.016). Of the patients who were referred because of seizures in front of the television, or evoked by a video- or computer game, 14% proved not to be photosensitive. Although no difference in age or use of medication was found, twice as many men were found in this nonphotosensitive group.

  13. The sensitivity and specificity of Lassa virus IgM by ELISA as screening tool at early phase of Lassa fever infection

    PubMed Central

    Ibekwe, Titus S.; Nwegbu, Maxwell M.; Asogun, Daniel; Adomeh, Donatus I.; Okokhere, Peter O.

    2012-01-01

    Background: Early diagnosis, prompt treatment, and disease containment are vital measures in the management of Lassa fever (LF), a lethal and contagious arenaviral hemorrhagic disease prevalent in West Africa. Lassa Virus (LAV)-specific Reverse Transcriptase Polymerase Chain Reaction (RT-PCR) test, the gold standard for diagnosis, is unavailable in most centers. Serologic detection of LAV IgM is a more accessible tool and this work was to investigate its adequacy as an early marker for LF. Patients and Methods: A prospective case–control study conducted July 2007-March 2011 in a tertiary referral health center in Nigeria. Blood samples for test and control were evaluated for Lassa specific antigens and IgM using RT-PCR (primers S36+ and LVS 339) and indirect ELISA (Lassa Nucleo-protein (NP)-Antigen) respectively. RT-PCR outcome was used as standard to test for the sensitivity and specificity of IgM. Results: Of the 37 confirmed cases of LF infection by RT-PCR, 21 (57%) were IgM positive. Amongst the 35 confirmed negative cases (control group), eight were IgM positive. The diagnostic sensitivity and specificity of the IgM assay were 57% and 77% respectively. The negative and positive predictive values of the IgM serological assay were 63% and 72%, respectively, while the efficiency of the test was 67%. Conclusion: The specificity and sensitivity of IgM as a screening tool for early detection of LF appear weak and, hence, the need for a reliable LF “rapid screening kit” since RT-PCR is unavailable in most centers. In the interim, “high clinical index of suspicion,” irrespective of IgM status, requires urgent referral to confirmatory centers. PMID:23661877

  14. The sensitivity and specificity of Lassa virus IgM by ELISA as screening tool at early phase of Lassa fever infection.

    PubMed

    Ibekwe, Titus S; Nwegbu, Maxwell M; Asogun, Daniel; Adomeh, Donatus I; Okokhere, Peter O

    2012-10-01

    Early diagnosis, prompt treatment, and disease containment are vital measures in the management of Lassa fever (LF), a lethal and contagious arenaviral hemorrhagic disease prevalent in West Africa. Lassa Virus (LAV)-specific Reverse Transcriptase Polymerase Chain Reaction (RT-PCR) test, the gold standard for diagnosis, is unavailable in most centers. Serologic detection of LAV IgM is a more accessible tool and this work was to investigate its adequacy as an early marker for LF. A prospective case-control study conducted July 2007-March 2011 in a tertiary referral health center in Nigeria. Blood samples for test and control were evaluated for Lassa specific antigens and IgM using RT-PCR (primers S36+ and LVS 339) and indirect ELISA (Lassa Nucleo-protein (NP)-Antigen) respectively. RT-PCR outcome was used as standard to test for the sensitivity and specificity of IgM. Of the 37 confirmed cases of LF infection by RT-PCR, 21 (57%) were IgM positive. Amongst the 35 confirmed negative cases (control group), eight were IgM positive. The diagnostic sensitivity and specificity of the IgM assay were 57% and 77% respectively. The negative and positive predictive values of the IgM serological assay were 63% and 72%, respectively, while the efficiency of the test was 67%. The specificity and sensitivity of IgM as a screening tool for early detection of LF appear weak and, hence, the need for a reliable LF "rapid screening kit" since RT-PCR is unavailable in most centers. In the interim, "high clinical index of suspicion," irrespective of IgM status, requires urgent referral to confirmatory centers.

  15. 40 CFR 86.113-07 - Fuel specifications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Heavy-Duty Vehicles; Test Procedures § 86.113-07 Fuel specifications. Section 86.113-07 includes text... that incorporate sulfur-sensitive technologies, the manufacturer may test the vehicle using a test fuel...., certified to California and EPA standards), the manufacturer may test the vehicle using a test fuel whose...

  16. 40 CFR 86.113-07 - Fuel specifications.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Heavy-Duty Vehicles; Test Procedures § 86.113-07 Fuel specifications. Section 86.113-07 includes text... that incorporate sulfur-sensitive technologies, the manufacturer may test the vehicle using a test fuel...., certified to California and EPA standards), the manufacturer may test the vehicle using a test fuel whose...

  17. 40 CFR 86.113-07 - Fuel specifications.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Heavy-Duty Vehicles; Test Procedures § 86.113-07 Fuel specifications. Section 86.113-07 includes text... that incorporate sulfur-sensitive technologies, the manufacturer may test the vehicle using a test fuel...., certified to California and EPA standards), the manufacturer may test the vehicle using a test fuel whose...

  18. 40 CFR 86.113-07 - Fuel specifications.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Heavy-Duty Vehicles; Test Procedures § 86.113-07 Fuel specifications. Section 86.113-07 includes text... that incorporate sulfur-sensitive technologies, the manufacturer may test the vehicle using a test fuel...., certified to California and EPA standards), the manufacturer may test the vehicle using a test fuel whose...

  19. Glenohumeral articular cartilage lesions: prospective comparison of non-contrast magnetic resonance imaging and findings at arthroscopy.

    PubMed

    Spencer, Brian A; Dolinskas, Carol A; Seymour, Peter A; Thomas, Stephen J; Abboud, Joseph A

    2013-09-01

    The purpose of this study was to assess the diagnostic sensitivity, specificity, accuracy, negative predictive value (NPV), positive predictive value (PPV), and test-retest reliability of magnetic resonance imaging (MRI) for detecting cartilage abnormalities of the glenohumeral joint in comparison with the gold standard of diagnostic arthroscopy. Forty-four patients with a preoperative non-contrast MRI study of their affected shoulder underwent arthroscopy by one surgeon for rotator cuff tendinopathy from 2009 to 2010. Articular cartilage defects were prospectively recorded and graded according to the International Cartilage Repair Society classification system at the time of arthroscopy. One year after surgery, the preoperative MRI were reviewed by a board-certified radiologist and the treating surgeon for articular cartilage defects of both the humeral head and the glenoid. Sensitivity, specificity, accuracy, and test-retest reliability were calculated. At arthroscopy, 43% of the shoulders were found to have articular cartilage defects. When the readers' findings were combined, the sensitivity of detecting humeral lesions on MRI was 32%; specificity, 80%; accuracy, 63%; PPV, 57%; and NPV, 66%. The sensitivity of detecting glenoid lesions was 31%; specificity, 86%; accuracy, 76%; PPV, 33%; and NPV, 85%. This study finds that the overall accuracy of MRI in detecting articular cartilage damage in patients with the clinical diagnosis of subacromial pathology is moderate. Level II, development of diagnostic criteria based on consecutive patients with universally applied reference "gold" standard. Copyright © 2013 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  20. Recurrent rotator cuff tear: is ultrasound imaging reliable?

    PubMed

    Gilat, Ron; Atoun, Ehud; Cohen, Ornit; Tsvieli, Oren; Rath, Ehud; Lakstein, Dror; Levy, Ofer

    2018-02-02

    The diagnostic workup of the painful shoulder after rotator cuff repair (RCR) can be quite challenging. The aim of this study was to assess the reliability of ultrasonography (US) for the detection of recurrent rotator cuff tears in patients with shoulder pain after RCR. We hypothesized that US for the diagnosis of recurrent rotator cuff tear after RCR would not prove to be reliable when compared with surgical arthroscopic confirmation (gold standard). In this cohort study (diagnosis), we retrospectively analyzed the data of 39 patients with shoulder pain after arthroscopic RCR who had subsequently undergone US, followed by revision arthroscopy. The rotator cuff was evaluated first using US for the presence of retears. Thereafter, revision arthroscopy was performed, and the diagnosis was either established or disproved. The sensitivity and specificity of US were assessed in reference to revision arthroscopy (gold standard). A rotator cuff retear was indicated by US in 21 patients (54%) and by revision arthroscopy in 26 patients (67%). US showed a sensitivity of 80.8% and specificity of 100% in the diagnosis of rotator cuff retears. Omission of partial rotator cuff retears resulted in a spike in sensitivity to 94.7%, with 100% specificity remaining. US imaging is a highly sensitive and specific test for the detection of recurrent rotator cuff tears, as confirmed by revision arthroscopy, in patients with a painful shoulder after primary RCR. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  1. Standardized Index of Shape (DCE-MRI) and Standardized Uptake Value (PET/CT): Two quantitative approaches to discriminate chemo-radiotherapy locally advanced rectal cancer responders under a functional profile

    PubMed Central

    Petrillo, Antonella; Fusco, Roberta; Petrillo, Mario; Granata, Vincenza; Delrio, Paolo; Bianco, Francesco; Pecori, Biagio; Botti, Gerardo; Tatangelo, Fabiana; Caracò, Corradina; Aloj, Luigi; Avallone, Antonio; Lastoria, Secondo

    2017-01-01

    Purpose To investigate dynamic contrast enhanced-MRI (DCE-MRI) in the preoperative chemo-radiotherapy (CRT) assessment for locally advanced rectal cancer (LARC) compared to18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT). Methods 75 consecutive patients with LARC were enrolled in a prospective study. DCE-MRI analysis was performed measuring SIS: linear combination of percentage change (Δ) of maximum signal difference (MSD) and wash-out slope (WOS). 18F-FDG PET/CT analysis was performed using SUV maximum (SUVmax). Tumor regression grade (TRG) were estimated after surgery. Non-parametric tests, receiver operating characteristic were evaluated. Results 55 patients (TRG1-2) were classified as responders while 20 subjects as non responders. ΔSIS reached sensitivity of 93%, specificity of 80% and accuracy of 89% (cut-off 6%) to differentiate responders by non responders, sensitivity of 93%, specificity of 69% and accuracy of 79% (cut-off 30%) to identify pathological complete response (pCR). Therapy assessment via ΔSUVmax reached sensitivity of 67%, specificity of 75% and accuracy of 70% (cut-off 60%) to differentiate responders by non responders and sensitivity of 80%, specificity of 31% and accuracy of 51% (cut-off 44%) to identify pCR. Conclusions CRT response assessment by DCE-MRI analysis shows a higher predictive ability than 18F-FDG PET/CT in LARC patients allowing to better discriminate significant and pCR. PMID:28042958

  2. Validity of diagnoses, procedures, and laboratory data in Japanese administrative data.

    PubMed

    Yamana, Hayato; Moriwaki, Mutsuko; Horiguchi, Hiromasa; Kodan, Mariko; Fushimi, Kiyohide; Yasunaga, Hideo

    2017-10-01

    Validation of recorded data is a prerequisite for studies that utilize administrative databases. The present study evaluated the validity of diagnoses and procedure records in the Japanese Diagnosis Procedure Combination (DPC) data, along with laboratory test results in the newly-introduced Standardized Structured Medical Record Information Exchange (SS-MIX) data. Between November 2015 and February 2016, we conducted chart reviews of 315 patients hospitalized between April 2014 and March 2015 in four middle-sized acute-care hospitals in Shizuoka, Kochi, Fukuoka, and Saga Prefectures and used them as reference standards. The sensitivity and specificity of DPC data in identifying 16 diseases and 10 common procedures were identified. The accuracy of SS-MIX data for 13 laboratory test results was also examined. The specificity of diagnoses in the DPC data exceeded 96%, while the sensitivity was below 50% for seven diseases and variable across diseases. When limited to primary diagnoses, the sensitivity and specificity were 78.9% and 93.2%, respectively. The sensitivity of procedure records exceeded 90% for six procedures, and the specificity exceeded 90% for nine procedures. Agreement between the SS-MIX data and the chart reviews was above 95% for all 13 items. The validity of diagnoses and procedure records in the DPC data and laboratory results in the SS-MIX data was high in general, supporting their use in future studies. Copyright © 2017 The Authors. Production and hosting by Elsevier B.V. All rights reserved.

  3. Standardized Index of Shape (DCE-MRI) and Standardized Uptake Value (PET/CT): Two quantitative approaches to discriminate chemo-radiotherapy locally advanced rectal cancer responders under a functional profile.

    PubMed

    Petrillo, Antonella; Fusco, Roberta; Petrillo, Mario; Granata, Vincenza; Delrio, Paolo; Bianco, Francesco; Pecori, Biagio; Botti, Gerardo; Tatangelo, Fabiana; Caracò, Corradina; Aloj, Luigi; Avallone, Antonio; Lastoria, Secondo

    2017-01-31

    To investigate dynamic contrast enhanced-MRI (DCE-MRI) in the preoperative chemo-radiotherapy (CRT) assessment for locally advanced rectal cancer (LARC) compared to18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT). 75 consecutive patients with LARC were enrolled in a prospective study. DCE-MRI analysis was performed measuring SIS: linear combination of percentage change (Δ) of maximum signal difference (MSD) and wash-out slope (WOS). 18F-FDG PET/CT analysis was performed using SUV maximum (SUVmax). Tumor regression grade (TRG) were estimated after surgery. Non-parametric tests, receiver operating characteristic were evaluated. 55 patients (TRG1-2) were classified as responders while 20 subjects as non responders. ΔSIS reached sensitivity of 93%, specificity of 80% and accuracy of 89% (cut-off 6%) to differentiate responders by non responders, sensitivity of 93%, specificity of 69% and accuracy of 79% (cut-off 30%) to identify pathological complete response (pCR). Therapy assessment via ΔSUVmax reached sensitivity of 67%, specificity of 75% and accuracy of 70% (cut-off 60%) to differentiate responders by non responders and sensitivity of 80%, specificity of 31% and accuracy of 51% (cut-off 44%) to identify pCR. CRT response assessment by DCE-MRI analysis shows a higher predictive ability than 18F-FDG PET/CT in LARC patients allowing to better discriminate significant and pCR.

  4. Sensitivity and responsiveness of the health-related quality of life in stroke patients-40 (HRQOLISP-40) scale.

    PubMed

    Vincent-Onabajo, Grace O; Owolabi, Mayowa O; Hamzat, Talhatu K

    2014-01-01

    To investigate the sensitivity and responsiveness of the Health-Related Quality of Life in Stroke Patients-40 (HRQOLISP-40) scale in evaluating stroke patients from onset to 12 months. Fifty-five patients with first-incidence stroke were followed-up for 12 months. The HRQOLISP-40 scale was used to assess health-related quality of life (HRQOL) while stroke severity was assessed with the Stroke Levity Scale. Sensitivity to change was assessed by analyzing changes in the HRQOLISP-40 scores between pairs of months with paired samples t-test. Standardized effect size (SES) and standardized response mean (SRM) were used to express responsiveness. Overall HRQOL and domains in the physical sphere of the HRQOLISP-40 were sensitive to change at different time intervals in the first 12 months post-stroke. Marked responsiveness (SES and SRM >0.7) was demonstrated by the overall scale, and the physical, psycho-emotional and cognitive domains at varying time intervals. For instance, SRM was greater than 0.7 between 1 and 6, 3 and 12, 1 and 9, and 1 and 12 months for both the physical and psycho-emotional domains. The HRQOLISP-40 is a sensitive and responsive stroke-specific quality of life measure that can be used to evaluate the outcome of stroke rehabilitation. Enhancing the health-related quality of life (HRQOL) of stroke survivors can be regarded as the ultimate goal of stroke rehabilitation. Sensitive and responsive stroke-specific HRQOL measures are required for use in evaluative studies, and clinical trials and practice. The Health-Related Quality of Life in Stroke Patients-40 (HRQOLISP-40) is a sensitive and responsive stroke-specific scale.

  5. An experimental analysis of disgust sensitivity and fear of contagion in Spider and Blood Injection Injury Phobia.

    PubMed

    Bianchi, Kristin N; Carter, Michele M

    2012-10-01

    Disgust sensitivity and concern with contamination have been frequently associated with Spider and Blood-Injection-Injury (BII) Phobias. This study assessed the domain specificity of disgust sensitivity and concern with contamination in 29 Non-Phobic Controls, 25 clinical Spider Phobics, 26 clinical BII Phobics, and 27 persons who met clinical criteria for Spider Phobia and BII Phobia. On self-report measures we found evidence of domain specificity of disgust sensitivity for the Spider and BII Phobia groups. Furthermore, we found that persons with both phobias may be more disgust sensitive than persons with a single phobia. Interestingly, the animal reminder disgust stimulus used in this research was more sensitive to detecting domain specific differences in disgust sensitivity between Phobic groups than was the core disgust stimulus, emphasizing the importance of developing standardized behavioral measures of disgust sensitivity in future research. Lastly, findings from this research suggest that concern with contamination may be more influential in phobic avoidance for persons with Spider Phobia than for persons with BII Phobia. Treatment implications for these findings are discussed. Copyright © 2012 Elsevier Ltd. All rights reserved.

  6. Evaluation of an On-Farm Culture System (Accumast) for Fast Identification of Milk Pathogens Associated with Clinical Mastitis in Dairy Cows.

    PubMed

    Ganda, Erika Korzune; Bisinotto, Rafael Sisconeto; Decter, Dean Harrison; Bicalho, Rodrigo Carvalho

    2016-01-01

    The present study aimed evaluate an on-farm culture system for identification of milk pathogens associated with clinical mastitis in dairy cows using two different gold standard approaches: standard laboratory culture in study 1 and 16S rRNA sequencing in study 2. In study 1, milk from mastitic quarters (i.e. presence of flakes, clots, or serous milk; n = 538) was cultured on-farm using a single plate containing three selective chromogenic media (Accumast-FERA Animal Health LCC, Ithaca, NY) and in a reference laboratory using standard culture methods, which was considered the gold standard. In study 2, mastitic milk was cultured on-farm and analyzed through 16S rRNA sequencing (n = 214). In both studies, plates were cultured aerobically at 37°C for 24 h and read by a single technician masked to gold standard results. Accuracy, sensitivity, specificity, positive (PPV) and negative predictive value (NPV) were calculated based on standard laboratory culture in study 1, and PPV was calculated based on sequencing results in study 2. Overall accuracy of Accumast was 84.9%. Likewise, accuracy for identification of Gram-negative bacteria, Staphylococcus sp., and Streptococcus sp. was 96.4%, 93.8%, and 91.5%, respectively. Sensitivity, specificity, PPV, and NPV were 75.0%, 97.9%, 79.6%, and 97.3% for identification of E. coli, 100.0%, 99.8%, 87.5%, and 100.0% for S. aureus, 70.0%, 95.0%, 45.7%, and 98.1% for other Staphylococcus sp., and 90.0%, 92.9%, 91.8%, and 91.2% for Streptococcus sp. In study 2, Accumast PPV was 96.7% for E. coli, 100.0% for Enterococcus sp., 100.0% for Other Gram-negatives, 88.2% for Staphylococcus sp., and 95.0% for Streptococcus sp., respectively. In conclusion, Accumast is a unique approach for on-farm identification pathogens associated with mastitis, presenting overall sensitivity and specificity of 82.3% and 89.9% respectively.

  7. Evaluation of an On-Farm Culture System (Accumast) for Fast Identification of Milk Pathogens Associated with Clinical Mastitis in Dairy Cows

    PubMed Central

    Ganda, Erika Korzune; Bisinotto, Rafael Sisconeto; Decter, Dean Harrison; Bicalho, Rodrigo Carvalho

    2016-01-01

    The present study aimed evaluate an on-farm culture system for identification of milk pathogens associated with clinical mastitis in dairy cows using two different gold standard approaches: standard laboratory culture in study 1 and 16S rRNA sequencing in study 2. In study 1, milk from mastitic quarters (i.e. presence of flakes, clots, or serous milk; n = 538) was cultured on-farm using a single plate containing three selective chromogenic media (Accumast—FERA Animal Health LCC, Ithaca, NY) and in a reference laboratory using standard culture methods, which was considered the gold standard. In study 2, mastitic milk was cultured on-farm and analyzed through 16S rRNA sequencing (n = 214). In both studies, plates were cultured aerobically at 37°C for 24 h and read by a single technician masked to gold standard results. Accuracy, sensitivity, specificity, positive (PPV) and negative predictive value (NPV) were calculated based on standard laboratory culture in study 1, and PPV was calculated based on sequencing results in study 2. Overall accuracy of Accumast was 84.9%. Likewise, accuracy for identification of Gram-negative bacteria, Staphylococcus sp., and Streptococcus sp. was 96.4%, 93.8%, and 91.5%, respectively. Sensitivity, specificity, PPV, and NPV were 75.0%, 97.9%, 79.6%, and 97.3% for identification of E. coli, 100.0%, 99.8%, 87.5%, and 100.0% for S. aureus, 70.0%, 95.0%, 45.7%, and 98.1% for other Staphylococcus sp., and 90.0%, 92.9%, 91.8%, and 91.2% for Streptococcus sp. In study 2, Accumast PPV was 96.7% for E. coli, 100.0% for Enterococcus sp., 100.0% for Other Gram-negatives, 88.2% for Staphylococcus sp., and 95.0% for Streptococcus sp., respectively. In conclusion, Accumast is a unique approach for on-farm identification pathogens associated with mastitis, presenting overall sensitivity and specificity of 82.3% and 89.9% respectively. PMID:27176216

  8. Can Automated Imaging for Optic Disc and Retinal Nerve Fiber Layer Analysis Aid Glaucoma Detection?

    PubMed

    Banister, Katie; Boachie, Charles; Bourne, Rupert; Cook, Jonathan; Burr, Jennifer M; Ramsay, Craig; Garway-Heath, David; Gray, Joanne; McMeekin, Peter; Hernández, Rodolfo; Azuara-Blanco, Augusto

    2016-05-01

    To compare the diagnostic performance of automated imaging for glaucoma. Prospective, direct comparison study. Adults with suspected glaucoma or ocular hypertension referred to hospital eye services in the United Kingdom. We evaluated 4 automated imaging test algorithms: the Heidelberg Retinal Tomography (HRT; Heidelberg Engineering, Heidelberg, Germany) glaucoma probability score (GPS), the HRT Moorfields regression analysis (MRA), scanning laser polarimetry (GDx enhanced corneal compensation; Glaucoma Diagnostics (GDx), Carl Zeiss Meditec, Dublin, CA) nerve fiber indicator (NFI), and Spectralis optical coherence tomography (OCT; Heidelberg Engineering) retinal nerve fiber layer (RNFL) classification. We defined abnormal tests as an automated classification of outside normal limits for HRT and OCT or NFI ≥ 56 (GDx). We conducted a sensitivity analysis, using borderline abnormal image classifications. The reference standard was clinical diagnosis by a masked glaucoma expert including standardized clinical assessment and automated perimetry. We analyzed 1 eye per patient (the one with more advanced disease). We also evaluated the performance according to severity and using a combination of 2 technologies. Sensitivity and specificity, likelihood ratios, diagnostic, odds ratio, and proportion of indeterminate tests. We recruited 955 participants, and 943 were included in the analysis. The average age was 60.5 years (standard deviation, 13.8 years); 51.1% were women. Glaucoma was diagnosed in at least 1 eye in 16.8%; 32% of participants had no glaucoma-related findings. The HRT MRA had the highest sensitivity (87.0%; 95% confidence interval [CI], 80.2%-92.1%), but lowest specificity (63.9%; 95% CI, 60.2%-67.4%); GDx had the lowest sensitivity (35.1%; 95% CI, 27.0%-43.8%), but the highest specificity (97.2%; 95% CI, 95.6%-98.3%). The HRT GPS sensitivity was 81.5% (95% CI, 73.9%-87.6%), and specificity was 67.7% (95% CI, 64.2%-71.2%); OCT sensitivity was 76.9% (95% CI, 69.2%-83.4%), and specificity was 78.5% (95% CI, 75.4%-81.4%). Including only eyes with severe glaucoma, sensitivity increased: HRT MRA, HRT GPS, and OCT would miss 5% of eyes, and GDx would miss 21% of eyes. A combination of 2 different tests did not improve the accuracy substantially. Automated imaging technologies can aid clinicians in diagnosing glaucoma, but may not replace current strategies because they can miss some cases of severe glaucoma. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.

  9. Assessment of simple colorimetric procedures to determine smoking status of diabetic subjects.

    PubMed

    Smith, R F; Mather, H M; Ellard, G A

    1998-02-01

    The performance of a simple colorimetric assay for urinary nicotine metabolites to assess smoking status in diabetic subjects (n = 251) was investigated. Several variations of the colorimetric assay and a qualitative extraction procedure were evaluated in comparison with a cotinine immunoassay as the "gold standard." Among these, the best overall performance was achieved with the qualitative test (sensitivity 95%; specificity 100%). The quantitative measurement of total nicotine metabolites performed less well (sensitivity 92%; specificity 97%) but could be improved by incorporating a blank extraction (sensitivity 98%; specificity 98%). Allowance for diuresis appeared to offer no advantage over the other methods. These results support previous findings regarding the use of these colorimetric procedures in nondiabetic subjects and, contrary to other recent observations, their performance was not impaired in diabetic patients.

  10. [Implication of inverse-probability weighting method in the evaluation of diagnostic test with verification bias].

    PubMed

    Kang, Leni; Zhang, Shaokai; Zhao, Fanghui; Qiao, Youlin

    2014-03-01

    To evaluate and adjust the verification bias existed in the screening or diagnostic tests. Inverse-probability weighting method was used to adjust the sensitivity and specificity of the diagnostic tests, with an example of cervical cancer screening used to introduce the Compare Tests package in R software which could be implemented. Sensitivity and specificity calculated from the traditional method and maximum likelihood estimation method were compared to the results from Inverse-probability weighting method in the random-sampled example. The true sensitivity and specificity of the HPV self-sampling test were 83.53% (95%CI:74.23-89.93)and 85.86% (95%CI: 84.23-87.36). In the analysis of data with randomly missing verification by gold standard, the sensitivity and specificity calculated by traditional method were 90.48% (95%CI:80.74-95.56)and 71.96% (95%CI:68.71-75.00), respectively. The adjusted sensitivity and specificity under the use of Inverse-probability weighting method were 82.25% (95% CI:63.11-92.62) and 85.80% (95% CI: 85.09-86.47), respectively, whereas they were 80.13% (95%CI:66.81-93.46)and 85.80% (95%CI: 84.20-87.41) under the maximum likelihood estimation method. The inverse-probability weighting method could effectively adjust the sensitivity and specificity of a diagnostic test when verification bias existed, especially when complex sampling appeared.

  11. Prospective evaluation of fluciclovine (18F) PET-CT and MRI in detection of recurrent prostate cancer in non-prostatectomy patients.

    PubMed

    Akin-Akintayo, Oladunni; Tade, Funmilayo; Mittal, Pardeep; Moreno, Courtney; Nieh, Peter T; Rossi, Peter; Patil, Dattatraya; Halkar, Raghuveer; Fei, Baowei; Master, Viraj; Jani, Ashesh B; Kitajima, Hiroumi; Osunkoya, Adeboye O; Ormenisan-Gherasim, Claudia; Goodman, Mark M; Schuster, David M

    2018-05-01

    To investigate the disease detection rate, diagnostic performance and interobserver agreement of fluciclovine ( 18 F) PET-CT and multiparametric magnetic resonance imaging (mpMR) in recurrent prostate cancer. Twenty-four patients with biochemical failure after non-prostatectomy definitive therapy, 16/24 of whom had undergone brachytherapy, underwent fluciclovine PET-CT and mpMR with interpretation by expert readers blinded to patient history, PSA and other imaging results. Reference standard was established via a multidisciplinary truth panel utilizing histology and clinical follow-up (22.9 ± 10.5 months) and emphasizing biochemical control. The truth panel was blinded to investigative imaging results. Diagnostic performance and interobserver agreement (kappa) for the prostate and extraprostatic regions were calculated for each of 2 readers for PET-CT (P1 and P2) and 2 different readers for mpMR (M1 and M2). On a whole body basis, the detection rate for fluciclovine PET-CT was 94.7% (both readers), while it ranged from 31.6-36.8% for mpMR. Kappa for fluciclovine PET-CT was 0.90 in the prostate and 1.0 in the extraprostatic regions. For mpMR, kappa was 0.25 and 0.74, respectively. In the prostate, 22/24 patients met the reference standard with 13 malignant and 9 benign results. Sensitivity, specificity and positive predictive value (PPV) were 100.0%, 11.1% and 61.9%, respectively for both PET readers. For mpMR readers, values ranged from 15.4-38.5% for sensitivity, 55.6-77.8% for specificity and 50.0-55.6% for PPV. For extraprostatic disease determination, 18/24 patients met the reference standard. Sensitivity, specificity and PPV were 87.5%, 90.0% and 87.5%, respectively, for fluciclovine PET-CT, while for mpMR, sensitivity ranged from 50 to 75%, specificity 70-80% and PPV 57-75%. The disease detection rate for fluciclovine PET-CT in non-prostatectomy patients with biochemical failure was 94.7% versus 31.6-36.8% for mpMR. For extraprostatic disease detection, fluciclovine PET-CT had overall better diagnostic performance than mpMR. For the treated prostate, fluciclovine PET-CT had high sensitivity though low specificity for disease detection, while mpMR had higher specificity, though low sensitivity. Interobserver agreement was also higher with fluciclovine PET-CT compared with mpMR. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Prospective comparison of RT-PCR/ESI-MS to Prodesse ProFlu Plus and Cepheid GenXpert for the detection of Influenza A and B viruses.

    PubMed

    Hardick, Justin; Dugas, Andrea; Goheen, Joshua; Rothman, Richard; Gaydos, Charlotte

    2015-03-01

    RT-PCR/ESI-MS has previously demonstrated the capability to detect and identify respiratory viral pathogens in nasopharyngeal swabs. This study expands on previous research by performing a prospective evaluation of RT-PCR/ESI-MS to detect and identify Influenza A and B viruses compared to Prodesse ProFlu Plus and combined ProFlu Plus and Cepheid Xpert Flu. ProFlu Plus was also used as a gold standard for comparison for respiratory syncytial virus detection. Using ProFlu Plus as a gold standard, RT-PCR/ESI-MS had sensitivity and specificity of 82.1% (23/28) and 100% (258/258), respectively, for Influenza A, 100% (16/16) and 99.6% (269/270), respectively for Influenza B, and 88.6% (39/44) and 99.6% (241/242) for any Influenza virus. Using matching results from ProFlu Plus and Xpert Flu as a gold standard, RT-PCR/ESI-MS had 85.2% (23/27) and 100% (259/259) sensitivity and specificity respectively for Influenza A, 100% (14/14) and 99.6% (270/272), respectively for Influenza B virus. Overall, RT-PCR/ESI-MS was not as sensitive as the combined gold standard of ProFlu Plus and Xpert Flu, although it has the capability of detecting other respiratory viruses. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. High-resolution melting analysis for noninvasive prenatal diagnosis of IVS-II-I (G-A) fetal DNA in minor beta-thalassemia mothers.

    PubMed

    Zafari, Mandana; Gill, Pooria; Kowsaryan, Mehrnoush; Alipour, Abbass; Banihashemi, Ali

    2016-10-01

    The high-resolution melting (HRM) technique is fast, effective and successful method for mutation detection. The aim of this study was to determine the sensitivity and specificity of the HRM method for detection of a paternally inherited mutation in a fetus as a noninvasive prenatal diagnosis of β-thalassemia. Genomic DNAs were prepared from 50 β-thalassemia minor couples whose pregnancy was at risk for homozygous β-thalassemia. Ten milliliters of the maternal blood from each pregnant woman were collected and after separating plasma stored at -80 °C until analysis. The extracted DNAs were analyzed by HRM real-time PCR for detection of IVS-II-I (G-A) as a paternally inherited mutation. The gold standard was the result of a chorionic villus sampling by a standard reverse dot blotting test. The sensitivity and specificity of HRM real-time PCR were 92.6% and 82.6%, respectively. Also, the positive and negative predictive values were 86.2% and 90.47%, respectively. HRM real-time PCR was a sensitive and specific method for determining the paternally inherited mutation in the fetus at risk with thalassemia major.

  14. Comparison of bronchoalveolar lavage cytology and transbronchial biopsy in the diagnosis of carcinoma of lung.

    PubMed

    Ahmed, Ayesha; Ahmed, Sajjad

    2004-01-01

    The objectives of this study were to compare bronchoalveolar lavage (BAL) cytology and transbronchial biopsy in the diagnosis of carcinoma lung and to determine accuracy of BAL cytology using histopathlologic examination of transbronchial biopsy as gold standard at our center. This study was carried out at Department of Histopathology, Ayub Medical College, Abbottabad, from 1.09.2000 to 28.02.2003. BAL fluid and bronchial biopsy were received and processed simultaneously. Four cytology and a set of histopathology slides were prepared. These were screened and diagnosis recorded. Sensitivity, Specificity, False Positive, False Negative, Positive predictive value and Negative predictive value of BAL cytology were determined using histopathology of transbronchial biopsy as gold standard. We found the sensitivity of BAL cytology to be 93.44% as compared with transbronchial biopsy. The specificity was 100%. There was no false positive while false negative results were 6.55 %. The positive predictive value was 100 %, while the negative predictive value was 75 %. The overall diagnostic efficacy of BAL cytology was 94.52 %. BAL cytology is a highly sensitive and specific test for diagnosis of carcinoma lung. It can be used as a quick and reliable diagnostic method for diagnosis of lung malignancy.

  15. Identification of the need for home visiting nurse: development of a new assessment tool.

    PubMed

    Taguchi, Atsuko; Nagata, Satoko; Naruse, Takashi; Kuwahara, Yuki; Yamaguchi, Takuhiro; Murashima, Sachiyo

    2014-01-01

    To develop a Home Visiting Nursing Service Need Assessment Form (HVNS-NAF) to standardize the decision about the need for home visiting nursing service. The sample consisted of older adults who had received coordinated services by care managers. We defined the need for home visiting nursing service by elderly individuals as the decision of the need by a care manager so that the elderly can continue to live independently. Explanatory variables included demographic factors, medical procedure, severity of illness, and caregiver variables. Multiple logistic regression was carried out after univariate analyses to decide the variables to include and the weight of each variable in the HVNS-NAF. We then calculated the sensitivity and specificity of each cutoff value, and defined the score with the highest sensitivity and specificity as the cutoff value. Nineteen items were included in the final HVNS-NAF. When the cutoff value was 2 points, the sensitivity was 77.0%, specificity 68.5%, and positive predictive value 56.8%. HVNS-NAF is the first validated standard based on characteristics of elderly clients who required home visiting nursing service. Using the HVNS-NAF may result in reducing the unmet need for home visiting nursing service and preventing hospitalization.

  16. Differentiation of Mycobacterium tuberculosis complex from non-tubercular mycobacteria by nested multiplex PCR targeting IS6110, MTP40 and 32kD alpha antigen encoding gene fragments.

    PubMed

    Sinha, Pallavi; Gupta, Anamika; Prakash, Pradyot; Anupurba, Shampa; Tripathi, Rajneesh; Srivastava, G N

    2016-03-12

    Control of the global burden of tuberculosis is obstructed due to lack of simple, rapid and cost effective diagnostic techniques that can be used in resource poor-settings. To facilitate the early diagnosis of TB directly from clinical specimens, we have standardized and validated the use of nested multiplex PCR, targeting gene fragments IS6110, MTP40 and 32kD α-antigen encoding genes specific for Mycobacterium tuberculosis complex and non-tubercular mycobacteria (NTM), in comparison to smear microscopy, solid culture and single step multiplex PCR. The results were evaluated in comparison to a composite reference standard (CRS) comprising of microbiological results (smear and culture), clinical, radiological and cytopathological findings, clinical treatment and response to anti-tubercular therapy. The nested multiplex PCR (nMPCR) assay was evaluated to test its utility in 600 (535 pulmonary and 65 extra-pulmonary specimens) clinically suspected TB cases. All specimens were processed for smear, culture, single step multiplex PCR and nested multiplex PCR testing. Out of 535 screened pulmonary and 65 extra-pulmonary specimens, 329 (61.5%) and 19 (29.2%) cases were culture positive for M. tuberculosis. Based on CRS, 450 patients had "clinical TB" (definitive-TB, probable-TB and possible-TB). Remaining 150 were confirmed "non-TB" cases. For culture, the sensitivity was low, 79.3% for pulmonary and 54.3% for extra-pulmonary cases. The sensitivity and specificity results for nMPCR test were evaluated taken composite reference standard as a gold standard. The sensitivity of the nMPCR assay was 97.1% for pulmonary and 91.4% for extra-pulmonary TB cases with specificity of 100% and 93.3% respectively. Nested multiplex PCR using three gene primers is a rapid, reliable and highly sensitive and specific diagnostic technique for the detection and differentiation of M. tuberculosis complex from NTM genome and will be useful in diagnosing paucibacillary samples. Nested multiplex PCR assay was found to be better than single step multiplex PCR for assessing the diagnosis of TB.

  17. Which cuff should I use? Indirect blood pressure measurement for the diagnosis of hypertension in patients with obesity: a diagnostic accuracy review.

    PubMed

    Irving, Greg; Holden, John; Stevens, Richard; McManus, Richard J

    2016-11-03

    To determine the diagnostic accuracy of different methods of blood pressure (BP) measurement compared with reference standards for the diagnosis of hypertension in patients with obesity with a large arm circumference. Systematic review with meta-analysis with hierarchical summary receiver operating characteristic models. Bland-Altman analyses where individual patient data were available. Methodological quality appraised using Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS2) criteria. MEDLINE, EMBASE, Cochrane, DARE, Medion and Trip databases were searched. Cross-sectional, randomised and cohort studies of diagnostic test accuracy that compared any non-invasive BP tests (upper arm, forearm, wrist, finger) with an appropriate reference standard (invasive BP, correctly fitting upper arm cuff, ambulatory BP monitoring) in primary care were included. 4037 potentially relevant papers were identified. 20 studies involving 26 different comparisons met the inclusion criteria. Individual patient data were available from 4 studies. No studies satisfied all QUADAS2 criteria. Compared with the reference test of invasive BP, a correctly fitting upper arm BP cuff had a sensitivity of 0.87 (0.79 to 0.93) and a specificity of 0.85 (0.64 to 0.95); insufficient evidence was available for other comparisons to invasive BP. Compared with the reference test of a correctly fitting upper arm cuff, BP measurement at the wrist had a sensitivity of 0.92 (0.64 to 0.99) and a specificity of 0.92 (0.85 to 0.87). Measurement with an incorrectly fitting standard cuff had a sensitivity of 0.73 (0.67 to 0.78) and a specificity of 0.76 (0.69 to 0.82). Measurement at the forearm had a sensitivity of 0.84 (0.71 to 0.92) and a specificity 0.75 of (0.66 to 0.83). Bland-Altman analysis of individual patient data from 3 studies comparing wrist and upper arm BP showed a mean difference of 0.46 mm Hg for systolic BP measurement and 2.2 mm Hg for diastolic BP measurement. BP measurement with a correctly fitting upper arm cuff is sufficiently sensitive and specific to diagnose hypertension in patients with obesity with a large upper arm circumference. If a correctly fitting upper arm cuff cannot be applied, an incorrectly fitting standard size cuff should not be used and BP measurement at the wrist should be considered. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  18. Which cuff should I use? Indirect blood pressure measurement for the diagnosis of hypertension in patients with obesity: a diagnostic accuracy review

    PubMed Central

    Holden, John

    2016-01-01

    Objective To determine the diagnostic accuracy of different methods of blood pressure (BP) measurement compared with reference standards for the diagnosis of hypertension in patients with obesity with a large arm circumference. Design Systematic review with meta-analysis with hierarchical summary receiver operating characteristic models. Bland-Altman analyses where individual patient data were available. Methodological quality appraised using Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS2) criteria. Data sources MEDLINE, EMBASE, Cochrane, DARE, Medion and Trip databases were searched. Eligibility criteria Cross-sectional, randomised and cohort studies of diagnostic test accuracy that compared any non-invasive BP tests (upper arm, forearm, wrist, finger) with an appropriate reference standard (invasive BP, correctly fitting upper arm cuff, ambulatory BP monitoring) in primary care were included. Results 4037 potentially relevant papers were identified. 20 studies involving 26 different comparisons met the inclusion criteria. Individual patient data were available from 4 studies. No studies satisfied all QUADAS2 criteria. Compared with the reference test of invasive BP, a correctly fitting upper arm BP cuff had a sensitivity of 0.87 (0.79 to 0.93) and a specificity of 0.85 (0.64 to 0.95); insufficient evidence was available for other comparisons to invasive BP. Compared with the reference test of a correctly fitting upper arm cuff, BP measurement at the wrist had a sensitivity of 0.92 (0.64 to 0.99) and a specificity of 0.92 (0.85 to 0.87). Measurement with an incorrectly fitting standard cuff had a sensitivity of 0.73 (0.67 to 0.78) and a specificity of 0.76 (0.69 to 0.82). Measurement at the forearm had a sensitivity of 0.84 (0.71 to 0.92) and a specificity 0.75 of (0.66 to 0.83). Bland-Altman analysis of individual patient data from 3 studies comparing wrist and upper arm BP showed a mean difference of 0.46 mm Hg for systolic BP measurement and 2.2 mm Hg for diastolic BP measurement. Conclusions BP measurement with a correctly fitting upper arm cuff is sufficiently sensitive and specific to diagnose hypertension in patients with obesity with a large upper arm circumference. If a correctly fitting upper arm cuff cannot be applied, an incorrectly fitting standard size cuff should not be used and BP measurement at the wrist should be considered. PMID:27810973

  19. High sensitivity and specificity of clinical microscopy in rural health facilities in western Kenya under an external quality assurance program.

    PubMed

    Wafula, Rebeccah; Sang, Edna; Cheruiyot, Olympia; Aboto, Angeline; Menya, Diana; O'Meara, Wendy Prudhomme

    2014-09-01

    Microscopic diagnosis of malaria is a well-established and inexpensive technique that has the potential to provide accurate diagnosis of malaria infection. However, it requires both training and experience. Although it is considered the gold standard in research settings, the sensitivity and specificity of routine microscopy for clinical care in the primary care setting has been reported to be unacceptably low. We established a monthly external quality assurance program to monitor the performance of clinical microscopy in 17 rural health centers in western Kenya. The average sensitivity over the 12-month period was 96% and the average specificity was 88%. We identified specific contextual factors that contributed to inadequate performance. Maintaining high-quality malaria diagnosis in high-volume, resource-constrained health facilities is possible. © The American Society of Tropical Medicine and Hygiene.

  20. Fusion positron emission/computed tomography underestimates the presence of hilar nodal metastases in patients with resected non-small cell lung cancer.

    PubMed

    Carrillo, Sergio A; Daniel, Vincent C; Hall, Nathan; Hitchcock, Charles L; Ross, Patrick; Kassis, Edmund S

    2012-05-01

    The 5-year survival for patients with resected stage II (N1) non-small cell lung cancer ranges from 40% to 55%. No data exist addressing the benefit of neoadjuvant therapy for patients with stage II disease. This is largely in part due to the lack of a reliable, minimally invasive method to assess hilar nodes. This study is aimed at determining the ability of fusion positron emission/computed tomography (PET/CT) to identify hilar metastases in patients with resected non-small cell lung cancer. A retrospective review of surgically resected patients with fusion PET/CT within 30 days of resection was performed. The sensitivity, specificity, positive predictive value, and negative predictive value for PET/CT in detecting hilar nodal metastases was calculated for a range of maximum standardized uptake values (SUVmax). Hilar nodes from patients with falsely positive PET/CT scans were analyzed for the presence of histoplasmosis. Additionally, the impact of hilar node size greater than 1 centimeter on the calculated values was assessed. There were 119 patients evaluated. The number of lymph nodes resected ranged from 1 to 12 (X=2.98). There was decreased sensitivity and increased specificity with higher SUVmax cutoff values. At the standard SUVmax value of 2.5, the sensitivity and specificity were only 48.5% and 80.2%. The addition of size of hilar node by CT led to a modest improvement in sensitivity at all SUVmax cutoff values. Fusion PET/CT lacks sensitivity and specificity in identifying hilar nodal metastasis in patients with resected non-small cell lung cancer. Further prospective studies assessing the utility of PET/CT versus alternative sampling techniques are warranted. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  1. Concurrent evaluation of visual, cytological and HPV testing as screening methods for the early detection of cervical neoplasia in Mumbai, India.

    PubMed

    Shastri, Surendra S; Dinshaw, Ketayun; Amin, Geetanjali; Goswami, Smriti; Patil, Sharmila; Chinoy, Roshini; Kane, S; Kelkar, Rohini; Muwonge, Richard; Mahé, Cédric; Ajit, Dulhan; Sankaranarayanan, R

    2005-03-01

    Naked eye visual inspection with acetic acid (VIA), magnified VIA (VIAM), visual inspection with Lugol's iodine (VILI), cytology and human papillomavirus (HPV) testing were evaluated as screening methods for the detection of high-grade squamous intraepithelial lesions (HSIL) of the uterine cervix in a cross-sectional study in Mumbai, India. Cytology, HPV testing, VIA, VIAM and VILI were carried out concurrently for 4039 women aged 30-65 years. All women were investigated with colposcopy and biopsies were taken from 939 women who had colposcopic abnormalities. The reference standard for final disease status was histology or negative colposcopy. The presence of HSIL was confirmed in 57 women (1.4%). The test characteristics for each method were calculated using standard formulae. The sensitivities of cytology, HPV testing, VIA, VIAM and VILI were 57.4%, 62.0%, 59.7%, 64.9%, and 75.4%, respectively (differences were not statistically significant). The specificities were 98.6%, 93.5%, 88.4%, 86.3%, and 84.3%, respectively. Adding a visual test to cytology or HPV testing in parallel combination resulted in a substantial increase in sensitivity, with a moderate decrease in specificity. The parallel combination of VILI and HPV testing resulted in a sensitivity of 92.0% and a specificity of 79.9%. As a single test, cytology had the best balance of sensitivity and specificity. Visual tests are promising in low-resource settings, such as India. The use of both VIA and VILI may be considered where good quality cytology or HPV testing are not feasible. The sensitivity of cytology and HPV testing increased significantly when combined with VIA or VILI.

  2. Fluorescence optical imaging and 3T-MRI for detection of synovitis in patients with rheumatoid arthritis in comparison to a composite standard of reference.

    PubMed

    Thuermel, Klaus; Neumann, Jan; Jungmann, Pia M; Schäffeler, Christoph; Waldt, Simone; Heinze, Alexander; Beckmann, Alexander; Hauser, Christine; Hasenau, Anna-Lena; Wildgruber, Moritz; Clotten, Sigrun; Sievert, Matti; Haller, Bernhard; Woertler, Klaus; Harasser, Norbert; Rummeny, Ernst J; Meier, Reinhard

    2017-05-01

    To address whether Indocyanine Green (ICG) enhanced fluorescence optical imaging (FOI) is more sensitive than magnetic resonance imaging (MRI) in the detection of synovitis of the wrist and finger joints in rheumatoid arthritis and to analyze the performance of FOI depending on the grade of synovitis. Twenty patients with highly active rheumatoid arthritis (mean DAS28-ESR 5.25±1.0) and thirteen healthy volunteers underwent clinical examination, FOI and contrast-enhanced 3T-MRI. Joints were rated by three independent readers semiquantitatively (grade 0-3: no, low, moderate and high grade synovitis) and compared to a semiquantitative composite standard of reference (cSOR, grade 0-3) that incorporated clinical parameters, FOI and MRI results. 2.868 evaluations in 956 joints were performed. FOI had an overall sensitivity of 57.3% and a specificity of 92.1%, whereas MRI had a sensitivity of 89.2% and a specificity of 92.6%. The sensitivity of FOI increased with the degree of synovitis to 65.0% for moderate and severe synovitis (specificity 88.1%) and 76,3% for severe synovitis (specificity 80.5%). The performance of FOI decreased with the degree of synovitis with false negative results predominantly for mild (156/343, 45.5%) and moderate (160/343, 46.6%) synovitis and false positive FOI evaluations predominantly based on weak (grade 1) signals (133/163, 81,6%). FOI has a lower sensitivity than 3T-MRI in the detection of synovitis of the hand and finger joints. The diagnostic performance of FOI decreases with the degree of synovitis and with the strength of FOI signals. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Test Characteristics of Point of Care Ultrasound for the Diagnosis of Retinal Detachment in the Emergency Department.

    PubMed

    Kim, Daniel J; Francispragasam, Mario; Docherty, Gavin; Silver, Byron; Prager, Ross; Lee, Donna; Maberley, David

    2018-05-18

    Previous studies of point of care ultrasound (POCUS) have reported high sensitivities and specificities for retinal detachment (RD). Our primary objective was to assess the test characteristics of POCUS performed by a large heterogeneous group of emergency physicians (EPs) for the diagnosis of RD. This was a prospective diagnostic test assessment of POCUS performed by EPs with varying ultrasound experience on a convenience sample of emergency department (ED) patients presenting with flashes or floaters in one or both eyes. After standard ED assessment, EPs performed an ocular POCUS scan targeted to detect the presence or absence of RD. After completing their ED visit, all patients were assessed by a retina specialist who was blinded to the results of the POCUS scan. We calculated sensitivity and specificity with associated exact binomial confidence intervals (CI) using the retina specialist's final diagnosis as the reference standard. A total of 30 EPs enrolled 115 patients, with median age of 60 years and 64% female. The retina specialist diagnosed RD in 16 (14%) cases. The sensitivity and specificity of POCUS for detecting RD was 75% (95% CI 48%-93%) and 94% (95% CI 87%-98%), respectively. The positive likelihood ratio was 12.4 (95% CI 5.4-28.3), and negative likelihood ratio was 0.27 (95% CI 0.11-0.62). A large heterogeneous group of EPs can perform POCUS with high specificity but only intermediate sensitivity for RD. A negative POCUS scan in the ED performed by a heterogeneous group of providers after a one-hour POCUS didactic is not sufficiently sensitive to rule out RD in a patient with new onset flashes or floaters. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  4. Diagnostic Accuracy of Memory Measures in Alzheimer's Dementia and Mild Cognitive Impairment: a Systematic Review and Meta-Analysis.

    PubMed

    Weissberger, Gali H; Strong, Jessica V; Stefanidis, Kayla B; Summers, Mathew J; Bondi, Mark W; Stricker, Nikki H

    2017-12-01

    With an increasing focus on biomarkers in dementia research, illustrating the role of neuropsychological assessment in detecting mild cognitive impairment (MCI) and Alzheimer's dementia (AD) is important. This systematic review and meta-analysis, conducted in accordance with PRISMA (Preferred Reporting Items for Systematic reviews and Meta-Analyses) standards, summarizes the sensitivity and specificity of memory measures in individuals with MCI and AD. Both meta-analytic and qualitative examination of AD versus healthy control (HC) studies (n = 47) revealed generally high sensitivity and specificity (≥ 80% for AD comparisons) for measures of immediate (sensitivity = 87%, specificity = 88%) and delayed memory (sensitivity = 89%, specificity = 89%), especially those involving word-list recall. Examination of MCI versus HC studies (n = 38) revealed generally lower diagnostic accuracy for both immediate (sensitivity = 72%, specificity = 81%) and delayed memory (sensitivity = 75%, specificity = 81%). Measures that differentiated AD from other conditions (n = 10 studies) yielded mixed results, with generally high sensitivity in the context of low or variable specificity. Results confirm that memory measures have high diagnostic accuracy for identification of AD, are promising but require further refinement for identification of MCI, and provide support for ongoing investigation of neuropsychological assessment as a cognitive biomarker of preclinical AD. Emphasizing diagnostic test accuracy statistics over null hypothesis testing in future studies will promote the ongoing use of neuropsychological tests as Alzheimer's disease research and clinical criteria increasingly rely upon cerebrospinal fluid (CSF) and neuroimaging biomarkers.

  5. Measurement of neutralizing serum antibodies of patients vaccinated with human papillomavirus L1 or L2-based immunogens using furin-cleaved HPV Pseudovirions.

    PubMed

    Wang, Joshua W; Jagu, Subhashini; Wang, Chenguang; Kitchener, Henry C; Daayana, Sai; Stern, Peter L; Pang, Susana; Day, Patricia M; Huh, Warner K; Roden, Richard B S

    2014-01-01

    Antibodies specific for neutralizing epitopes in either Human papillomavirus (HPV) capsid protein L1 or L2 can mediate protection from viral challenge and thus their accurate and sensitive measurement at high throughput is likely informative for monitoring response to prophylactic vaccination. Here we compare measurement of L1 and L2-specific neutralizing antibodies in human sera using the standard Pseudovirion-Based Neutralization Assay (L1-PBNA) with the newer Furin-Cleaved Pseudovirion-Based Neutralization Assay (FC-PBNA), a modification of the L1-PBNA intended to improve sensitivity towards L2-specific neutralizing antibodies without compromising assay of L1-specific responses. For detection of L1-specific neutralizing antibodies in human sera, the FC- PBNA and L1-PBNA assays showed similar sensitivity and a high level of correlation using WHO standard sera (n = 2), and sera from patients vaccinated with Gardasil (n = 30) or an experimental human papillomavirus type 16 (HPV16) L1 VLP vaccine (n = 70). The detection of L1-specific cross-neutralizing antibodies in these sera using pseudovirions of types phylogenetically-related to those targeted by the L1 virus-like particle (VLP) vaccines was also consistent between the two assays. However, for sera from patients (n = 17) vaccinated with an L2-based immunogen (TA-CIN), the FC-PBNA was more sensitive than the L1-PBNA in detecting L2-specific neutralizing antibodies. Further, the neutralizing antibody titers measured with the FC-PBNA correlated with those determined with the L2-PBNA, another modification of the L1-PBNA that spacio-temporally separates primary and secondary receptor engagement, as well as the protective titers measured using passive transfer studies in the murine genital-challenge model. In sum, the FC-PBNA provided sensitive measurement for both L1 VLP and L2-specific neutralizing antibody in human sera. Vaccination with TA-CIN elicits weak cross-protective antibody in a subset of patients, suggesting the need for an adjuvant.

  6. Patient safety and systematic reviews: finding papers indexed in MEDLINE, EMBASE and CINAHL.

    PubMed

    Tanon, A A; Champagne, F; Contandriopoulos, A-P; Pomey, M-P; Vadeboncoeur, A; Nguyen, H

    2010-10-01

    To develop search strategies for identifying papers on patient safety in MEDLINE, EMBASE and CINAHL. Six journals were electronically searched for papers on patient safety published between 2000 and 2006. Identified papers were divided into two gold standards: one to build and the other to validate the search strategies. Candidate terms for strategy construction were identified using a word frequency analysis of titles, abstracts and keywords used to index the papers in the databases. Searches were run for each one of the selected terms independently in every database. Sensitivity, precision and specificity were calculated for each candidate term. Terms with sensitivity greater than 10% were combined to form the final strategies. The search strategies developed were run against the validation gold standard to assess their performance. A final step in the validation process was to compare the performance of each strategy to those of other strategies found in the literature. We developed strategies for all three databases that were highly sensitive (range 95%-100%), precise (range 40%-60%) and balanced (the product of sensitivity and precision being in the range of 30%-40%). The strategies were very specific and outperformed those found in the literature. The strategies we developed can meet the needs of users aiming to maximise either sensitivity or precision, or seeking a reasonable compromise between sensitivity and precision, when searching for papers on patient safety in MEDLINE, EMBASE or CINAHL.

  7. Swan-neck sign of the big toe - association with hypocalcaemia.

    PubMed

    Agarwal, Kishore S; Baijal, Noopur; Tiwari, Lokesh; Verma, Neeraj; Sahni, Mohit; Puliyel, Jacob M

    2007-10-01

    The sensitivity and specificity of a new clinical sign of hypocalcaemia were evaluated. The Swan-neck sign, wherein infants with symptomatic hypocalcaemia keep their big toe hyperextended at the metatarsophalangeal joint and flexed at the interphalangeal joint, was looked for in 25 infants presenting with non-febrile seizures, alongside their serum calcium levels. The study showed that the sign had a sensitivity of 63.6% and specificity of 66.6%. (Predictive values of positive and negative tests were 93.3% and 20%, respectively.) This is compared with the standard Trousseau and Chvostek signs.

  8. Assessment of the diagnostic sensitivity and specificity of an indirect ELISA kit for the diagnosis of Brucella ovis infection in rams.

    PubMed

    Praud, Anne; Champion, Jean-Luc; Corde, Yannick; Drapeau, Antoine; Meyer, Laurence; Garin-Bastuji, Bruno

    2012-07-09

    Brucella ovis causes an infectious disease responsible for infertility and subsequent economic losses in sheep production. The standard serological test to detect B. ovis infection in rams is the complement fixation test (CFT), which has imperfect sensitivity and specificity in addition to technical drawbacks. Other available tests include the indirect enzyme-linked immunosorbent assays (I-ELISA) but no I-ELISA kit has been fully evaluated.The study aimed to compare an I-ELISA kit and the standard CFT. Our study was carried out on serum samples from 4599 rams from the South of France where the disease is enzootic. A Bayesian approach was used to estimate tests characteristics (diagnostic sensitivity, Se and diagnostic specificity, Sp). The tests were then studied together in order to optimise testing strategies to detect B. ovis. After optimising the cut-off values in order to avoid doubtful results without deteriorating the concordance between the results of the two tests, the I-ELISA appeared to be slightly more sensitive than CFT (Se I-ELISA=0.917 [0.822; 0.992], 95% Credibility Interval (CrI) compared to Se CFT=0.860 [0.740; 0.967], 95% CrI). However, CFT was slightly more specific than I-ELISA (Sp CFT=0.988 [0.947; 1.0], 95% CrI) compared to Sp I-ELISA =0.952 [0.901; 1.0], 95% CrI).The tests were then associated with two different interpretation schemes. The series association increased the specificity of screening and could be used for pre-movement testing in rams from uninfected flocks. The parallel association increased sequence sensitivity, thus appearing more suitable for eradicating the disease in infected flocks. The high sensitivity and acceptable specificity of this I-ELISA kit support its potential interest to avoid the limitations of CFT. The two tests could also be used together or combined with other diagnostic methods such as semen culture to improve the testing strategy. The choice of test sequence and interpretation criteria depends on the epidemiological context, screening objectives and the financial and practical constraints.

  9. Rapid and Accurate Diagnosis of Acute Pyogenic Meningitis Due to Streptococcus Pneumoniae, Haemophilus influenzae Type b and Neisseria meningitidis Using A Multiplex PCR Assay.

    PubMed

    Seth, Rajeev; Murthy, Peela Sree Ramchandra; Sistla, Sujatha; Subramanian, Mahadevan; Tamilarasu, Kadhiravan

    2017-09-01

    Acute bacterial meningitis is one of the major causes of morbidity and mortality in children and geriatric population, especially in developing countries. Methods of identification are standard culture and other phenotypic tests in many resource poor settings. To use molecular methods for the improvement of aetiological diagnosis of acute pyogenic meningitis in patients. CSF samples of 125 patients were included for the study. Gram staining and culture were performed according to standard procedures. Antigen was detected using commercial latex agglutination test kit. Multiplex PCR was performed using previously published primers and protocols. Fischer's exact test was used for finding association between presence of the disease and clinical/biochemical parameters, considering two tailed p<0.05 as statistically significant. Sensitivity, specificity, positive and negative predictive values were calculated using Graphpad QuicCalc software. A total of 39 cases (31.2%) were confirmed to be of acute pyogenic meningitis based on biochemical methods. Only 10/39 was positive for the three organisms tested. Multiplex PCR was able to detect one additional isolate each of Streptococcus pneumoniae and Haemophilus influenzae type b. When compared with multiplex PCR as the gold standard, culture and latex agglutination tests had same sensitivity (80%), specificity (100%), PPV (100%) and NPV (97.8%), whereas Gram stain had poor sensitivity (40%) and good specificity (95.6%). Detection rates were higher in multiplex PCR for the two organisms Streptococcus pneumoniae and Haemophilus influenzae type b. Multiplex PCR was more sensitive than culture or antigen detection, and employing this assay can significantly increase the speed and accuracy of identification of the pathogen.

  10. Evaluation of commercial skin prick test solutions for selected occupational allergens.

    PubMed

    van Kampen, V; de Blay, F; Folletti, I; Kobierski, P; Moscato, G; Olivieri, M; Quirce, S; Sastre, J; Walusiak-Skorupa, J; Kotschy-Lang, N; Müsken, H; Mahler, V; Schliemann, S; Ochmann, U; Sültz, J; Worm, M; Sander, I; Zahradnik, E; Brüning, T; Merget, R; Raulf-Heimsoth, M

    2013-01-01

    Skin prick testing (SPT) is an important step in the diagnosis of IgE-mediated occupational allergic diseases. The outcome of SPT is related to the quality of allergen extracts. Thus, the aim of the study was to assess different commercially available SPT solutions for selected occupational allergens. SPT was performed in 116 bakers, 47 farmers and 33 subjects exposed to natural rubber latex (NRL), all with work-related allergic symptoms. The SPT solutions from different manufacturers (n = 3-5) for wheat flour, rye flour, soy, cow hair/dander, storage mites (Tyrophagus putrescentiae, Lepidoglyphus destructor, Acarus siro) and NRL were analysed with respect to their protein and antigen contents. SPT was carried out in 16 allergy centres in six European countries using standardized procedures. Specific IgE values were used as the gold standard to calculate the sensitivity and specificity of SPT solutions. The optimal cut-point for each SPT solution was determined by Youden Index. Protein and antigen contents and patterns of the SPT solutions varied remarkably depending on the manufacturer. While SPT solutions for wheat flour and soy reached overall low sensitivities, sensitivities of other tested SPT solutions depended on the manufacturer. As a rule, solutions with higher protein and antigen content showed higher sensitivities and test efficiencies. There is a wide variability of SPT solutions for occupational allergens, and the sensitivity of several solutions is low. Thus, improvement and standardization of SPT solutions for occupational allergens is essential. © 2013 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.

  11. Diagnostic sensitivity and specificity of a participatory disease surveillance method for highly pathogenic avian influenza in household chicken flocks in Indonesia.

    PubMed

    Robyn, M; Priyono, W B; Kim, L M; Brum, E

    2012-06-01

    A study was conducted to assess the diagnostic sensitivity and specificity of a disease surveillance method for diagnosis of highly pathogenic avian influenza (HPAI) outbreaks in household chicken flocks used by participatory disease surveillance (PDS) teams in Yogyakarta Province, Indonesia. The Government of Indonesia, in partnership with the Food and Agriculture Organization of the United Nations, has implemented a PDS method for the detection of HPAI outbreaks in poultry since 2006. The PDS method in Indonesia utilizes both a clinical case definition (CD) and the result of a commercial rapid antigen test kit Yogyakarta 55611, to diagnose HPAI outbreaks, primarily in backyard chicken flocks. The following diagnostic sensitivities and specificities were obtained relative to real-time reverse transcription-PCR as the gold standard diagnostic test: 1) 89% sensitivity (CI95: 75%-97%) and 96% specificity (CI95: 89%-99%) for the PDS CD alone; 2) 86% sensitivity (CI95: 71%-95%) and 99% specificity (CI95: 94%-100%) for the rapid antigen test alone; and 3) 84% sensitivity (CI95: 68%-94%) and 100% specificity (CI95: 96%-100%) for the PDS CD result combined with the rapid antigen test result. Based on these results, HPAI outbreaks in extensively raised household chickens can be diagnosed with sufficient sensitivity and specificity using the PDS method as implemented in Indonesia. Subject to further field evaluation, data from this study suggest that the diagnostic sensitivity of the PDS method may be improved by expanding the PDS CD to include more possible clinical presentations of HPAI and by increasing the number of rapid antigen tests to three different birds with HPAI-compatible signs of same flock.

  12. Assessing the effectiveness of combining evaluation methods for the early identification of students with inadequate knowledge during a clerkship.

    PubMed

    Hemmer, Paul A.; Grau, Thomas; Pangaro, Louis N.

    2001-10-01

    This study examined the predictive validity of in-clerkship evaluation methods to identify medical students who have insufficient knowledge. Study subjects were 124 third-year medical students at the Uniformed Services University. Insufficient knowledge was defined by: (1) a clerkship 'pre-test' score one standard deviation below the mean or lower; or (2) any teacher verbally rating a student's general knowledge as 'marginal' or less; or (3) a student did not pass Step One of the United States Medical Licensing Examination (USMLE). We determined sensitivity and specificity using a standard score of 90%. Using USMLE Step One pass-fail performance did not improve sensitivity. Combining a 'pre-test' and instructors' formal evaluation session comments improves the early identification of students with insufficient knowledge, allowing for formative feedback and remediation during the clerkship.

  13. High resolution microendoscopy for early detection of esophageal cancer in low-resource settings (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Richards-Kortum, Rebecca

    2016-03-01

    Esophageal squamous cell neoplasia (ESCN) is the sixth leading cause of cancer death worldwide. Most deaths due to ESCN occur in developing countries, with highest risk areas in northern China. Lugol's chromoendoscopy (LCE) is the gold-standard for ESCN screening; while the sensitivity of LCE for ESCN is >95%, LCE suffers poor specificity (< 65%) due to false positive findings from inflammatory lesions. High resolution microendoscopy (HRME) uses a low-cost, fiber-optic fluorescence microscope to image morphology of the surface epithelium without need for biopsy. We developed a tablet-interfaced HRME with automated, real-time image analysis. In an in vivo study of 177 patients referred for endoscopy in China, use of the algorithm identified neoplasia with a sensitivity and specificity of 95% and 91% compared to the gold standard of histology.

  14. Utility of sepsis biomarkers and the infection probability score to discriminate sepsis and systemic inflammatory response syndrome in standard care patients.

    PubMed

    Ratzinger, Franz; Schuardt, Michael; Eichbichler, Katherina; Tsirkinidou, Irene; Bauer, Marlene; Haslacher, Helmuth; Mitteregger, Dieter; Binder, Michael; Burgmann, Heinz

    2013-01-01

    Physicians are regularly faced with severely ill patients at risk of developing infections. In literature, standard care wards are often neglected, although their patients frequently suffer from a systemic inflammatory response syndrome (SIRS) of unknown origin. Fast identification of patients with infections is vital, as they immediately require appropriate therapy. Further, tools with a high negative predictive value (NPV) to exclude infection or bacteremia are important to increase the cost effectiveness of microbiological examinations and to avoid inappropriate antibiotic treatment. In this prospective cohort study, 2,384 patients with suspected infections were screened for suffering from two or more SIRS criteria on standard care wards. The infection probability score (IPS) and sepsis biomarkers with discriminatory power were assessed regarding their capacity to identify infection or bacteremia. In this cohort finally consisting of 298 SIRS-patients, the infection prevalence was 72%. Bacteremia was found in 25% of cases. For the prediction of infection, the IPS yielded 0.51 ROC-AUC (30.1% sensitivity, 64.6% specificity). Among sepsis biomarkers, lipopolysaccharide binding protein (LBP) was the best parameter with 0.63 ROC-AUC (57.5% sensitivity, 67.1% specificity). For the prediction of bacteremia, the IPS performed slightly better with a ROC-AUC of 0.58 (21.3% sensitivity, 65% specificity). Procalcitonin was the best discriminator with 0.78 ROC-AUC, 86.3% sensitivity, 59.6% specificity and 92.9% NPV. Furthermore, bilirubin and LBP (ROC-AUC: 0.65, 0.62) might also be considered as useful parameters. In summary, the IPS and widely used infection parameters, including CRP or WBC, yielded a poor diagnostic performance for the detection of infection or bacteremia. Additional sepsis biomarkers do not aid in discriminating inflammation from infection. For the prediction of bacteremia procalcitonin, and bilirubin were the most promising parameters, which might be used as a rule for when to take blood cultures or using nucleic acid amplification tests for microbiological diagnostics.

  15. The diagnostic performance of reduced-dose CT for suspected appendicitis in paediatric and adult patients: A systematic review and diagnostic meta-analysis.

    PubMed

    Yoon, Hee Mang; Suh, Chong Hyun; Cho, Young Ah; Kim, Jeong Rye; Lee, Jin Seong; Jung, Ah Young; Kim, Jung Heon; Lee, Jeong-Yong; Kim, So Yeon

    2018-06-01

    To evaluate the diagnostic performance of reduced-dose CT for suspected appendicitis. A systematic search of the MEDLINE and EMBASE databases was carried out through to 10 January 2017. Studies evaluating the diagnostic performance of reduced-dose CT for suspected appendicitis in paediatric and adult patients were selected. Pooled summary estimates of sensitivity and specificity were calculated using hierarchical logistic regression modelling. Meta-regression was performed. Fourteen original articles with a total of 3,262 patients were included. For all studies using reduced-dose CT, the summary sensitivity was 96 % (95 % CI 93-98) with a summary specificity of 94 % (95 % CI 92-95). For the 11 studies providing a head-to-head comparison between reduced-dose CT and standard-dose CT, reduced-dose CT demonstrated a comparable summary sensitivity of 96 % (95 % CI 91-98) and specificity of 94 % (95 % CI 93-96) without any significant differences (p=.41). In meta-regression, there were no significant factors affecting the heterogeneity. The median effective radiation dose of the reduced-dose CT was 1.8 mSv (1.46-4.16 mSv), which was a 78 % reduction in effective radiation dose compared to the standard-dose CT. Reduced-dose CT shows excellent diagnostic performance for suspected appendicitis. • Reduced-dose CT shows excellent diagnostic performance for evaluating suspected appendicitis. • Reduced-dose CT has a comparable diagnostic performance to standard-dose CT. • Median effective radiation dose of reduced-dose CT was 1.8 mSv (1.46-4.16). • Reduced-dose CT achieved a 78 % dose reduction compared to standard-dose CT.

  16. Evaluation of the Performance of Five Diagnostic Tests for Fasciola hepatica Infection in Naturally Infected Cattle Using a Bayesian No Gold Standard Approach.

    PubMed

    Mazeri, Stella; Sargison, Neil; Kelly, Robert F; Bronsvoort, Barend M deC; Handel, Ian

    2016-01-01

    The clinical and economic importance of fasciolosis has been recognised for centuries, yet diagnostic tests available for cattle are far from perfect. Test evaluation has mainly been carried out using gold standard approaches or under experimental settings, the limitations of which are well known. In this study, a Bayesian no gold standard approach was used to estimate the diagnostic sensitivity and specificity of five tests for fasciolosis in cattle. These included detailed liver necropsy including gall bladder egg count, faecal egg counting, a commercially available copro-antigen ELISA, an in-house serum excretory/secretory antibody ELISA and routine abattoir liver inspection. In total 619 cattle slaughtered at one of Scotland's biggest abattoirs were sampled, during three sampling periods spanning summer 2013, winter 2014 and autumn 2014. Test sensitivities and specificities were estimated using an extension of the Hui Walter no gold standard model, where estimates were allowed to vary between seasons if tests were a priori believed to perform differently for any reason. The results of this analysis provide novel information on the performance of these tests in a naturally infected cattle population and at different times of the year where different levels of acute or chronic infection are expected. Accurate estimates of sensitivity and specificity will allow for routine abattoir liver inspection to be used as a tool for monitoring the epidemiology of F. hepatica as well as evaluating herd health planning. Furthermore, the results provide evidence to suggest that the copro-antigen ELISA does not cross-react with Calicophoron daubneyi rumen fluke parasites, while the serum antibody ELISA does.

  17. Evaluation of the OnSite (Pf/Pan) rapid diagnostic test for diagnosis of clinical malaria

    PubMed Central

    2012-01-01

    Background Accurate diagnosis of malaria is an essential prerequisite for proper treatment and drug resistance monitoring. Microscopy is considered the gold standard for malaria diagnosis but has limitations. ELISA, PCR, and Real Time PCR are also used to diagnose malaria in reference laboratories, although their application at the field level is currently not feasible. Rapid diagnostic tests (RDTs) however, have been brought into field operation and widely adopted in recent days. This study evaluates OnSite (Pf/Pan) antigen test, a new RDT introduced by CTK Biotech Inc, USA for malaria diagnosis in a reference setting. Methods Blood samples were collected from febrile patients referred for malaria diagnosis by clinicians. Subjects were included in this study from two different Upazila Health Complexes (UHCs) situated in two malaria endemic districts of Bangladesh. Microscopy and nested PCR were considered the gold standard in this study. OnSite (Pf/Pan) RDT was performed on preserved whole blood samples. Results In total, 372 febrile subjects were included in this study. Of these subjects, 229 (61.6%) tested positive for Plasmodium infection detected by microscopy and nested PCR. OnSite (Pf/Pan) RDT was 94.2% sensitive (95% CI, 89.3-97.3) and 99.5% specific (95% CI, 97.4-00.0) for Plasmodium falciparum diagnosis and 97.3% sensitive (95% CI, 90.5-99.7) and 98.7% specific (95% CI, 96.6-99.6) for Plasmodium vivax diagnosis. Sensitivity varied with differential parasite count for both P. falciparum and P. vivax. The highest sensitivity was observed in febrile patients with parasitaemia that ranged from 501–1,000 parasites/μL regardless of the Plasmodium species. Conclusion The new OnSite (Pf/Pan) RDT is both sensitive and specific for symptomatic malaria diagnosis in standard laboratory conditions. PMID:23234579

  18. The Mutation-Associated Neoantigen Functional Expansion of Specific T cells (MANAFEST) assay: a sensitive platform for monitoring antitumor immunity.

    PubMed

    Danilova, Ludmila; Anagnostou, Valsamo; Caushi, Justina X; Sidhom, John-William; Guo, Haidan; Chan, Hok Yee; Suri, Prerna; Tam, Ada J; Zhang, Jiajia; El Asmar, Margueritta; Marrone, Kristen A; Naidoo, Jarushka; Brahmer, Julie R; Forde, Patrick M; Baras, Alexander S; Cope, Leslie; Velculescu, Victor E; Pardoll, Drew; Housseau, Franck; Smith, Kellie N

    2018-06-12

    Mutation-associated neoantigens (MANAs) are a target of antitumor T-cell immunity. Sensitive, simple, and standardized assays are needed to assess the repertoire of functional MANA-specific T cells in oncology. Assays analyzing in vitro cytokine production such as ELISpot and intracellular cytokine staining (ICS) have been useful but have limited sensitivity in assessing tumor-specific T-cell responses and do not analyze antigen-specific T-cell repertoires. The FEST (Functional Expansion of Specific T cells) assay described herein integrates TCR sequencing of short-term, peptide-stimulated cultures with a bioinformatic platform to identify antigen-specific clonotypic amplifications. This assay can be adapted for all types of antigens, including mutation associated neoantigens (MANAs) via tumor exome-guided prediction of MANAs. Following in vitro identification by the MANAFEST assay, the MANA-specific CDR3 sequence can be used as a molecular barcode to detect and monitor the dynamics of these clonotypes in blood, tumor, and normal tissue of patients receiving immunotherapy. MANAFEST is compatible with high-throughput routine clinical and lab practices. Copyright ©2018, American Association for Cancer Research.

  19. Can hip abduction and external rotation discriminate sacroiliac joint pain?

    PubMed

    Adhia, Divya Bharatkumar; Tumilty, Steve; Mani, Ramakrishnan; Milosavljevic, Stephan; Bussey, Melanie D

    2016-02-01

    The primary aim of the study is to determine if Hip Abduction and External Rotation (HABER) test is capable of reproducing familiar pain in individuals with low back pain (LBP) of sacroiliac joint (SIJ) origin (SIJ-positive) when compared with LBP of Non-SIJ origin (SIJ-negative). If so, the secondary aim is to determine the diagnostic accuracy of HABER test against the reference standard of pain provocation tests, and to determine which increments of the HABER test has highest sensitivity and specificity for identifying SIJ-positive individuals. Single-blinded diagnostic accuracy study. Participants [n(122)] between ages of 18-50 y, suffering from chronic non-specific LBP (≥3 months) volunteered in the study. An experienced musculoskeletal physiotherapist evaluated and classified participants into either SIJ-positive [n(45)] or SIJ-negative [n(77)], based on reference standard of pain provocation tests [≥3 positive tests = SIJ-positive]. Another musculoskeletal physiotherapist, blinded to clinical groups, evaluated participants for reproduction of familiar pain during each increment (10°, 20°, 30°, 40°, and 50°) of HABER test. The HABER test reproduced familiar pain in SIJ-positive individuals when compared with SIJ-negative individuals [p (0.001), R(2) (0.38), Exp(β) (5.95-10.32)], and demonstrated moderate level of sensitivity (67%-78%) and specificity (71%-72%) for identifying SIJ-positive individuals. Receiver operator curve analysis demonstrated that the HABER increments of ≥30° have the highest sensitivity (83%-100%) and specificity (52%-64%). The HABER test is capable of reproducing familiar pain in SIJ-positive LBP individuals and has moderate levels of sensitivity and specificity for identifying SIJ-positive LBP individuals. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Diagnostic accuracy and reproducibility of the Ottawa Knee Rule vs the Pittsburgh Decision Rule.

    PubMed

    Cheung, Tung C; Tank, Yeliz; Breederveld, Roelf S; Tuinebreijer, Wim E; de Lange-de Klerk, Elly S M; Derksen, Robert J

    2013-04-01

    The aim of this present study was to compare the diagnostic accuracy and reproducibility of 2 clinical decision rules (the Ottawa Knee Rules [OKR] and Pittsburgh Decision Rules [PDR]) developed for selective use of x-rays in the evaluation of isolated knee trauma. Application of a decision rule leads to a more efficient evaluation of knee injuries and a reduction in health care costs. The diagnostic accuracy and reproducibility are compared in this study. A cross-sectional interobserver study was conducted in the emergency department of an urban teaching hospital from October 2008 to July 2009. Two observer groups collected data on standardized case-report forms: emergency medicine residents and surgical residents. Standard knee radiographs were performed in each patient. Participants were patients 18 years and older with isolated knee injuries. Pooled sensitivity and specificity were compared using χ(2) statistics, and interobserver agreement was calculated by using κ statistics. Ninety injuries were assessed. Seven injuries concerned fractures (7.8%). For the OKR, the pooled sensitivity and specificity were 0.86 (95% confidence interval [CI], 0.57-0.96) and 0.27 (95% CI, 0.21-0.35), respectively. The PDR had a pooled sensitivity and specificity of 0.86 (95% CI, 0.57-0.96) and 0.51 (95% CI, 0.44-0.59). The PDR was significantly (P = .002) more specific. The κ values for the OKR and PDR were 0.51 (95% CI, 0.32-0.71) and 0.71 (95% CI, 0.57-0.86), respectively. The PDR was found to be more specific than the OKR, with equal sensitivity. Interobserver agreement was moderate for the OKR and substantial for the PDR. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. External Validity of Electronic Sniffers for Automated Recognition of Acute Respiratory Distress Syndrome.

    PubMed

    McKown, Andrew C; Brown, Ryan M; Ware, Lorraine B; Wanderer, Jonathan P

    2017-01-01

    Automated electronic sniffers may be useful for early detection of acute respiratory distress syndrome (ARDS) for institution of treatment or clinical trial screening. In a prospective cohort of 2929 critically ill patients, we retrospectively applied published sniffer algorithms for automated detection of acute lung injury to assess their utility in diagnosis of ARDS in the first 4 ICU days. Radiographic full-text reports were searched for "edema" OR ("bilateral" AND "infiltrate") and a more detailed algorithm for descriptions consistent with ARDS. Patients were flagged as possible ARDS if a radiograph met search criteria and had a PaO 2 /FiO 2 or SpO 2 /FiO 2 of 300 or 315, respectively. Test characteristics of the electronic sniffers and clinical suspicion of ARDS were compared to a gold standard of 2-physician adjudicated ARDS. Thirty percent of 2841 patients included in the analysis had gold standard diagnosis of ARDS. The simpler algorithm had sensitivity for ARDS of 78.9%, specificity of 52%, positive predictive value (PPV) of 41%, and negative predictive value (NPV) of 85.3% over the 4-day study period. The more detailed algorithm had sensitivity of 88.2%, specificity of 55.4%, PPV of 45.6%, and NPV of 91.7%. Both algorithms were more sensitive but less specific than clinician suspicion, which had sensitivity of 40.7%, specificity of 94.8%, PPV of 78.2%, and NPV of 77.7%. Published electronic sniffer algorithms for ARDS may be useful automated screening tools for ARDS and improve on clinical recognition, but they are limited to screening rather than diagnosis because their specificity is poor.

  2. Assessment of nodal involvement in non-small-cell lung cancer with 18F-FDG-PET/CT: mediastinal blood pool cut-off has the highest sensitivity and tumour SUVmax/2 has the highest specificity.

    PubMed

    Mallorie, Amy; Goldring, James; Patel, Anant; Lim, Eric; Wagner, Thomas

    2017-08-01

    Lymph node involvement in non-small-cell lung cancer (NSCLC) is a major factor in determining management and prognosis. We aimed to evaluate the accuracy of fluorine-18-fluorodeoxyglucose-PET/computed tomography (CT) for the assessment of nodal involvement in patients with NSCLC. In this retrospective study, we included 61 patients with suspected or confirmed resectable NSCLC over a 2-year period from April 2013 to April 2015. 221 nodes with pathological staging from surgery or endobronchial ultrasound-guided transbronchial needle aspiration were assessed using a nodal station-based analysis with original clinical reports and three different cut-offs: mediastinal blood pool (MBP), liver background and tumour standardized uptake value maximal (SUVmax)/2. Using nodal station-based analysis for activity more than tumour SUVmax/2, the sensitivity was 45%, the specificity was 89% and the negative predictive value (NPV) was 87%. For activity more than MBP, the sensitivity was 93%, the specificity was 72% and NPV was 98%. For activity more than liver background, the sensitivity was 83%, the specificity was 84% and NPV was 96%. Using a nodal staging-based analysis for accuracy at detecting N2/3 disease, for activity more than tumour SUVmax/2, the sensitivity was 59%, the specificity was 85% and NPV was 80%. For activity more than MBP, the sensitivity was 95%, the specificity was 61% and NPV was 96%. For activity more than liver background, the sensitivity was 86%, the specificity was 81% and NPV was 92%. Receiver-operating characteristic analysis showed the optimal nodal SUVmax to be more than 6.4 with a sensitivity of 45% and a specificity of 95%, with an area under the curve of 0.85. Activity more than MBP was the most sensitive cut-off with the highest sensitivity and NPV. Activity more than primary tumour SUVmax/2 was the most specific cut-off. Nodal SUVmax more than 6.4 has a high specificity of 95%.

  3. Usefulness of the volume-viscosity swallow test for screening dysphagia in subacute stroke patients in rehabilitation income.

    PubMed

    Guillén-Solà, Anna; Marco, Ester; Martínez-Orfila, Joan; Donaire Mejías, M Fernanda; Depolo Passalacqua, Marina; Duarte, Esther; Escalada, Ferran

    2013-01-01

    Swallowing disorders affect up to 35-85% of patients with stroke. Dysphagia complications can lead to malnutrition, dehydration, bronchoaspirative pneumonia and death, and have impact on health care costs. To evaluate the clinical screening capacity of the Volume Viscosity Swallow Test (V-VST) for oropharyngeal dysphagia and aspiration in a homogeneous stroke patient sample. Cohort study of 52 stroke patients in a subacute phase. Piecemeal deglutition and oropharyngeal residue were considered signs of impaired efficacy and cough, fall in oxygen saturation and voice changes, signs of impaired safety. Sensitivity, specificity, positive and negative predictive values, accuracy and likelihood ratios were calculated for V-VST results and compared with those of videofluoroscopy (VFS), the gold standard for studies on swallowing disorders. The V-VST is a highly sensitive and specific test to detect aspiration with sensitivity of 88.2% and specificity of 71.4%; negative predictive value was 92.6%; accuracy index was 0.74. Sensitivity and specificity for penetration were 34.3% and 70.6%, respectively; accuracy was 32%. The V-VST is low in cost, easy to use and very sensitive, meeting the requirements of oropharyngeal dysphagia and aspiration screening test in subacute stroke patients.

  4. Glaucoma progression detection: agreement, sensitivity, and specificity of expert visual field evaluation, event analysis, and trend analysis.

    PubMed

    Antón, Alfonso; Pazos, Marta; Martín, Belén; Navero, José Manuel; Ayala, Miriam Eleonora; Castany, Marta; Martínez, Patricia; Bardavío, Javier

    2013-01-01

    To assess sensitivity, specificity, and agreement among automated event analysis, automated trend analysis, and expert evaluation to detect glaucoma progression. This was a prospective study that included 37 eyes with a follow-up of 36 months. All had glaucomatous disks and fields and performed reliable visual fields every 6 months. Each series of fields was assessed with 3 different methods: subjective assessment by 2 independent teams of glaucoma experts, glaucoma/guided progression analysis (GPA) event analysis, and GPA (visual field index-based) trend analysis. Kappa agreement coefficient between methods and sensitivity and specificity for each method using expert opinion as gold standard were calculated. The incidence of glaucoma progression was 16% to 18% in 3 years but only 3 cases showed progression with all 3 methods. Kappa agreement coefficient was high (k=0.82) between subjective expert assessment and GPA event analysis, and only moderate between these two and GPA trend analysis (k=0.57). Sensitivity and specificity for GPA event and GPA trend analysis were 71% and 96%, and 57% and 93%, respectively. The 3 methods detected similar numbers of progressing cases. The GPA event analysis and expert subjective assessment showed high agreement between them and moderate agreement with GPA trend analysis. In a period of 3 years, both methods of GPA analysis offered high specificity, event analysis showed 83% sensitivity, and trend analysis had a 66% sensitivity.

  5. Performance of loop-mediated isothermal amplification (LAMP) for the diagnosis of malaria among malaria suspected pregnant women in Northwest Ethiopia.

    PubMed

    Tegegne, Banchamlak; Getie, Sisay; Lemma, Wossenseged; Mohon, Abu Naser; Pillai, Dylan R

    2017-01-19

    Malaria is a major public health problem and an important cause of maternal and infant morbidity in sub-Saharan Africa, including Ethiopia. Early and accurate diagnosis of malaria with effective treatment is the best strategy for prevention and control of complications during pregnancy and infant morbidity and mortality. However, laboratory diagnosis has relied on the identification of malaria parasites and parasite antigens in peripheral blood using Giemsa-stained microscopy or rapid diagnostic tests (RDTs) which lack analytical and clinical sensitivity. The aim of this study was to evaluate the performance of loop-mediated isothermal amplification (LAMP) for the diagnosis of malaria among malaria suspected pregnant women in Northwest Ethiopia. A cross sectional study was conducted from January to April 2016. Pregnant women (n = 87) suspected of having malaria at six health centres were enrolled. A venous blood sample was collected from each study subject, and analysed for Plasmodium parasites by microscopy, RDT, and LAMP. Diagnostic accuracy outcome measures (sensitivity, specificity, predictive values, and Kappa scores) of microscopy, RDT and LAMP were compared to nested polymerase chain reaction (nPCR) as the gold standard. Specimen processing and reporting times were documented. Using nPCR as the gold standard technique, the sensitivity of microscopy and RDT was 90 and 70%, and the specificity was 98.7 and 97.4%, respectively. LAMP assay was 100% sensitive and 93.5% specific compared to nPCR. This study showed higher sensitivity of LAMP compared to microscopy and RDT for the detection of malaria in pregnancy. Increased sensitivity and ease of use with LAMP in point-of-care testing for malaria in pregnancy was noted. LAMP warrants further evaluation in intermittent screening and treatment programmes in pregnancy.

  6. Sensitivity and specificity of the Brøset Violence Checklist as predictor of violence in forensic psychiatry.

    PubMed

    Hvidhjelm, Jacob; Sestoft, Dorte; Skovgaard, Lene Theil; Bue Bjorner, Jakob

    2014-11-01

    Violence and aggressive behavior within psychiatric facilities are serious work environment problems, which have negative consequences for both patients and staff. It is therefore of great importance to reduce both the number and the severity of these violent incidents to improve quality of care. To evaluate the specificity and sensitivity of the Brøset Violence Checklist (BVC) as a predictor of violent incidents for Danish forensic psychiatry patients. A total of 156 patients were assessed three times daily with the BVC for 24 months. All aggressive or violent incidents were recorded using the Staff Observation Aggression Scale-Revised (SOAS-R). SOAS-R scores of 9 or more defined violent incidents. Data were analyzed using standard logistic regression models as well as models incorporating a random person effect. We used receiver operating curve (ROC) analysis to evaluate different BVC thresholds. Of a total of 139,579 BVC registrations we found 1999 scores above 0 and 419 violent incidents. The BVC score was a strong predictor of violence. For the standard cut-off point of 3, specificity was 0.997 and sensitivity was 0.656. For the general risk of violence seen in this study, the risk of violence given a BVC score > 3 (positive predictive value) was 37.2%, and the risk of violence given a BVC score < 3 (negative predictive value) was 0.1%. The BVC showed satisfactory specificity and sensitivity as a predictor of the short-term risk of violence against staff and others by patients in a forensic setting.

  7. Diagnostic Accuracy, Sensitivity, and Specificity of Executive Function Tests in Moderate Traumatic Brain Injury in Ghana.

    PubMed

    Adjorlolo, Samuel

    2018-06-01

    The sociocultural differences between Western and sub-Saharan African countries make it imperative to standardize neuropsychological tests in the latter. However, Western-normed tests are frequently administered in sub-Saharan Africa because of challenges hampering standardization efforts. Yet a salient topical issue in the cross-cultural neuropsychology literature relates to the utility of Western-normed neuropsychological tests in minority groups, non-Caucasians, and by extension Ghanaians. Consequently, this study investigates the diagnostic accuracy, sensitivity, and specificity of executive function (EF) tests (The Stroop Test, Trail Making Test, and Controlled Oral Word Association Test), and a Revised Quick Cognitive Screening Test (RQCST) in a sample of 50 patients diagnosed with moderate traumatic brain injury and 50 healthy controls in Ghana. The EF test scores showed good diagnostic accuracy, with area under the curve (AUC) values of the Trail Making Test scores ranging from .746 to .902. With respect to the Stroop Test scores, the AUC values ranged from .793 to .898, while Controlled Oral Word Association Test had AUC value of .787. The RQCST scores discriminated between the groups, with AUC values ranging from .674 to .912. The AUC values of composite EF score and a neuropsychological score created from EF and RQCST scores were .936 and. 942, respectively. Additionally, the Stroop Test, Trail Making Test, EF composite score, and RQCST scores showed good to excellent sensitivities and specificities. In general, this study has shown that commonly used EF tests in Western countries have diagnostic accuracy, sensitivity, and specificity when administered in Ghanaian samples. The findings and implications of the study are discussed.

  8. Development and evaluation of a novel LAMP assay for the diagnosis of Cutaneous and Visceral Leishmaniasis.

    PubMed

    Adams, Emily Rebecca; Schoone, Gerard; Versteeg, Inge; Gomez, Maria Adelaida; Diro, Ermias; Mori, Yasuyoshi; Perlee, Desiree; Downing, Tim; Saravia, Nancy; Assaye, Ashenafi; Hailu, Asrat; Albertini, Audrey; Ndung'u, Joseph Mathu; Schallig, Henk

    2018-04-25

    A novel Pan-Leishmania LAMP assay was developed for diagnosis of Cutaneous and Visceral Leishmaniasis (CL & VL) which can be used in near-patient settings. Primers were designed on the 18S rDNA and the conserved region of minicircle kDNA selected on the basis of high copy number. LAMP assays were evaluated for CL in a prospective cohort trial of 105 patients in South-West Colombia. Lesion swab samples from CL suspects were collected and tested using LAMP and compared to a composite reference of microscopy AND/OR culture to calculate diagnostic accuracy. LAMP assays were tested on 50 VL suspected patients from Ethiopia, including whole blood, peripheral blood mononuclear cells, and buffy coat. Diagnostic accuracy was calculated against a reference standard of microscopy of splenic or bone marrow aspirates. To calculate analytical specificity 100 clinical samples and isolates with fever causing pathogens including malaria, arboviruses and bacterial infections were tested. The LAMP assay had a sensitivity of 95% (95% CI: 87.2% - 98.5 %) and a specificity of 86% (95% CI: 67.3% -95.9 %) for the diagnosis of CL. On VL suspects the sensitivity was 92% (95% CI: 74.9 - 99.1%) and specificity of 100% (95% CI: 85.8-100%) in whole blood. For CL, LAMP is a sensitive tool for diagnosis and requires less equipment, time and expertise than alternative CL diagnostics. For VL, LAMP is sensitive using a minimally invasive sample as compared to the gold standard. The analytical specificity was 100%. Copyright © 2018 Adams et al.

  9. Performance comparison of the 4th generation Bio-Rad Laboratories GS HIV Combo Ag/Ab EIA on the EVOLIS™ automated system versus Abbott ARCHITECT HIV Ag/Ab Combo, Ortho Anti-HIV 1+2 EIA on Vitros ECi and Siemens HIV-1/O/2 enhanced on Advia Centaur.

    PubMed

    Mitchell, Elizabeth O; Stewart, Greg; Bajzik, Olivier; Ferret, Mathieu; Bentsen, Christopher; Shriver, M Kathleen

    2013-12-01

    A multisite study was conducted to evaluate the performance of the Bio-Rad 4th generation GS HIV Combo Ag/Ab EIA versus Abbott 4th generation ARCHITECT HIV Ag/Ab Combo. The performance of two 3rd generation EIAs, Ortho Diagnostics Anti-HIV 1+2 EIA and Siemens HIV 1/O/2 was also evaluated. Study objective was comparison of analytical HIV-1 p24 antigen detection, sensitivity in HIV-1 seroconversion panels, specificity in blood donors and two HIV false reactive panels. Analytical sensitivity was evaluated with International HIV-1 p24 antigen standards, the AFFSAPS (pg/mL) and WHO 90/636 (IU/mL) standards; sensitivity in acute infection was compared on 55 seroconversion samples, and specificity was evaluated on 1000 negative blood donors and two false reactive panels. GS HIV Combo Ag/Ab demonstrated better analytical HIV antigen sensitivity compared to ARCHITECT HIV Ag/Ab Combo: 0.41 IU/mL versus 1.2 IU/mL (WHO) and 12.7 pg/mL versus 20.1 pg/mL (AFSSAPS); GS HIV Combo Ag/Ab EIA also demonstrated slightly better specificity compared to ARCHITECT HIV Ag/Ab Combo (100% versus 99.7%). The 4th generation HIV Combo tests detected seroconversion 7-11 days earlier than the 3rd generation HIV antibody only EIAs. Both 4th generation immunoassays demonstrated excellent performance in sensitivity, with the reduction of the serological window period (7-11 days earlier detection than the 3rd generation HIV tests). However, GS HIV Combo Ag/Ab demonstrated improved HIV antigen analytical sensitivity and slightly better specificity when compared to ARCHITECT HIV Ag/Ab Combo assay, with higher positive predictive values (PPV) for low prevalence populations. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Diagnostic accuracy of the MMSE in detecting probable and possible Alzheimer's disease in ethnically diverse highly educated individuals: an analysis of the NACC database.

    PubMed

    Spering, Cynthia C; Hobson, Valerie; Lucas, John A; Menon, Chloe V; Hall, James R; O'Bryant, Sid E

    2012-08-01

    To validate and extend the findings of a raised cut score of O'Bryant and colleagues (O'Bryant SE, Humphreys JD, Smith GE, et al. Detecting dementia with the mini-mental state examination in highly educated individuals. Arch Neurol. 2008;65(7):963-967.) for the Mini-Mental State Examination in detecting cognitive dysfunction in a bilingual sample of highly educated ethnically diverse individuals. Archival data were reviewed from participants enrolled in the National Alzheimer's Coordinating Center minimum data set. Data on 7,093 individuals with 16 or more years of education were analyzed, including 2,337 cases with probable and possible Alzheimer's disease, 1,418 mild cognitive impairment patients, and 3,088 nondemented controls. Ethnic composition was characterized as follows: 6,296 Caucasians, 581 African Americans, 4 American Indians or Alaska natives, 2 native Hawaiians or Pacific Islanders, 149 Asians, 43 "Other," and 18 of unknown origin. Diagnostic accuracy estimates (sensitivity, specificity, and likelihood ratio) of Mini-Mental State Examination cut scores in detecting probable and possible Alzheimer's disease were examined. A standard Mini-Mental State Examination cut score of 24 (≤23) yielded a sensitivity of 0.58 and a specificity of 0.98 in detecting probable and possible Alzheimer's disease across ethnicities. A cut score of 27 (≤26) resulted in an improved balance of sensitivity and specificity (0.79 and 0.90, respectively). In the cognitively impaired group (mild cognitive impairment and probable and possible Alzheimer's disease), the standard cut score yielded a sensitivity of 0.38 and a specificity of 1.00 while raising the cut score to 27 resulted in an improved balance of 0.59 and 0.96 of sensitivity and specificity, respectively. These findings cross-validate our previous work and extend them to an ethnically diverse cohort. A higher cut score is needed to maximize diagnostic accuracy of the Mini-Mental State Examination in individuals with college degrees.

  11. Validation of Smartphone Based Retinal Photography for Diabetic Retinopathy Screening

    PubMed Central

    Rajalakshmi, Ramachandran; Arulmalar, Subramanian; Usha, Manoharan; Prathiba, Vijayaraghavan; Kareemuddin, Khaji Syed; Anjana, Ranjit Mohan; Mohan, Viswanathan

    2015-01-01

    Aim To evaluate the sensitivity and specificity of “fundus on phone’ (FOP) camera, a smartphone based retinal imaging system, as a screening tool for diabetic retinopathy (DR) detection and DR severity in comparison with 7-standard field digital retinal photography. Design Single-site, prospective, comparative, instrument validation study. Methods 301 patients (602 eyes) with type 2 diabetes underwent standard seven-field digital fundus photography with both Carl Zeiss fundus camera and indigenous FOP at a tertiary care diabetes centre in South India. Grading of DR was performed by two independent retina specialists using modified Early Treatment of Diabetic Retinopathy Study grading system. Sight threatening DR (STDR) was defined by the presence of proliferative DR(PDR) or diabetic macular edema. The sensitivity, specificity and image quality were assessed. Results The mean age of the participants was 53.5 ±9.6 years and mean duration of diabetes 12.5±7.3 years. The Zeiss camera showed that 43.9% had non-proliferative DR(NPDR) and 15.3% had PDR while the FOP camera showed that 40.2% had NPDR and 15.3% had PDR. The sensitivity and specificity for detecting any DR by FOP was 92.7% (95%CI 87.8–96.1) and 98.4% (95%CI 94.3–99.8) respectively and the kappa (ĸ) agreement was 0.90 (95%CI-0.85–0.95 p<0.001) while for STDR, the sensitivity was 87.9% (95%CI 83.2–92.9), specificity 94.9% (95%CI 89.7–98.2) and ĸ agreement was 0.80 (95%CI 0.71–0.89 p<0.001), compared to conventional photography. Conclusion Retinal photography using FOP camera is effective for screening and diagnosis of DR and STDR with high sensitivity and specificity and has substantial agreement with conventional retinal photography. PMID:26401839

  12. Measurement of blood pressure for the diagnosis and management of hypertension in different ethnic groups: one size fits all.

    PubMed

    Gill, Paramjit; Haque, M Sayeed; Martin, Una; Mant, Jonathan; Mohammed, Mohammed A; Heer, Gurdip; Johal, Amanpreet; Kaur, Ramandeep; Schwartz, Claire; Wood, Sally; Greenfield, Sheila M; McManus, Richard J

    2017-02-08

    Hypertension is a major risk factor for cardiovascular disease and prevalence varies by ethnic group. The diagnosis and management of blood pressure are informed by guidelines largely based on data from white populations. This study addressed whether accuracy of blood pressure measurement in terms of diagnosis of hypertension varies by ethnicity by comparing two measurement modalities (clinic blood pressure and home monitoring) with a reference standard of ambulatory BP monitoring in three ethnic groups. Cross-sectional population study (June 2010 - December 2012) with patients (40-75 years) of white British, South Asian and African Caribbean background with and without a previous diagnosis of hypertension recruited from 28 primary care practices. The study compared the test performance of clinic BP (using various protocols) and home-monitoring (1 week) with a reference standard of mean daytime ambulatory measurements using a threshold of 140/90 mmHg for clinic and 135/85 mmHg for out of office measurement. A total of 551 participants had complete data of whom 246 were white British, 147 South Asian and 158 African Caribbean. No consistent difference in accuracy of methods of blood pressure measurement was observed between ethnic groups with or without a prior diagnosis of hypertension: for people without hypertension, clinic measurement using three different methodologies had high specificity (75-97%) but variable sensitivity (33-65%) whereas home monitoring had sensitivity of 68-88% and specificity of 64-80%. For people with hypertension, detection of a raised blood pressure using clinic measurements had sensitivities of 34-69% with specificity of 73-92% and home monitoring had sensitivity (81-88%) and specificity (55-65%). For people without hypertension, ABPM remains the choice for diagnosing hypertension compared to the other modes of BP measurement regardless of ethnicity. Differences in accuracy of home monitoring and clinic monitoring (higher sensitivity of the former; higher specificity of the latter) were also not affected by ethnicity.

  13. Detection of Salmonella sp in chicken cuts using immunomagnetic separation

    PubMed Central

    de Cássia dos Santos da Conceição, Rita; Moreira, Ângela Nunes; Ramos, Roberta Juliano; Goularte, Fabiana Lemos; Carvalhal, José Beiro; Aleixo, José Antonio Guimarães

    2008-01-01

    The immunomagnetic separation (IMS) is a technique that has been used to increase sensitivity and specificity and to decrease the time required for detection of Salmonella in foods through different methodologies. In this work we report on the development of a method for detection of Salmonella in chicken cuts using in house antibody-sensitized microspheres associated to conventional plating in selective agar (IMS-plating). First, protein A-coated microspheres were sensitized with polyclonal antibodies against lipopolysacharide and flagella from salmonellae and used to standardize a procedure for capturing Salmonella Enteritidis from pure cultures and detection in selective agar. Subsequently, samples of chicken meat experimentally contaminated with S. Enteritidis were analyzed immediately after contamination and after 24h of refrigeration using three enrichment protocols. The detection limit of the IMS-plating procedure after standardization with pure culture was about 2x10 CFU/mL. The protocol using non-selective enrichment for 6-8h, selective enrichment for 16-18h and a post-enrichment for 4h gave the best results of S. Enteritidis detection by IMS-plating in experimentally contaminated meat. IMS-plating using this protocol was compared to the standard culture method for salmonellae detection in naturally contaminated chicken cuts and yielded 100% sensitivity and 94% specificity. The method developed using in house prepared magnetic microespheres for IMS and plating in selective agar was able to diminish by at least one day the time required for detection of Salmonella in chicken products by the conventional culture method. PMID:24031199

  14. Screening for diabetic retinopathy using digital colour photography and oral fluorescein angiography.

    PubMed

    Newsom, R; Moate, B; Casswell, T

    2000-08-01

    To evaluate digital colour photography and oral fluorescein angiography (OFA) for diabetic retinopathy screening. Thirty-seven patients were selected from either a diabetic retinopathy screening or a medical retina clinic. Three 45 degrees colour digital images and a single macula 45 degrees OFA image were taken from each eye. Standard seven-field stereo photography with ETDRS grading was used as a gold standard for data comparison. The images were assessed by two graders and the results of each method compared using the McNemar test. Five eyes had no diabetic retinopathy, 50 had background diabetic retinopathy, 3 had pre-proliferative diabetic retinopathy, 11 had proliferative disease and 3 had quiescent posttreatment disease. Clinically significant macular oedema was present in 25 eyes and absent in 48. For grading diabetic retinopathy digital colour photography produced a sensitivity of 0.87 (specificity 0.83); OFA produced a sensitivity of 0.87 (specificity 0.80) (p = 0.1). For the detection of diabetic maculopathy, the sensitivity of digital colour photography was 0.48 (specificity of 0.95) and for OFA was 0.87 (specificity 0.87) (p < 0.01). This pilot study has shown that both digital colour photography and OFA compare well with conventional methods for diabetic retinopathy screening. The results encourage the further evaluation of OFA in the screening for diabetic maculopathy.

  15. Bowel Ultrasonography in the Management of Crohn's Disease. A Review with Recommendations of an International Panel of Experts.

    PubMed

    Calabrese, Emma; Maaser, Christian; Zorzi, Francesca; Kannengiesser, Klaus; Hanauer, Stephen B; Bruining, David H; Iacucci, Marietta; Maconi, Giovanni; Novak, Kerri L; Panaccione, Remo; Strobel, Deike; Wilson, Stephanie R; Watanabe, Mamoru; Pallone, Francesco; Ghosh, Subrata

    2016-05-01

    Bowel ultrasonography (US) is considered a useful technique for assessing mural inflammation and complications in Crohn's disease (CD). The aim of this review is to appraise the evidence on the accuracy of bowel US for CD. In addition, we aim to provide recommendations for its optimal use. Publications were identified by literature search from 1992 to 2014 and selected based on predefined criteria: 15 or more patients; bowel US for diagnosing CD, complications, postoperative recurrence, activity; adequate reference standards; prospective study design; data reported to allow calculation of sensitivity, specificity, agreement, or correlation values; articles published in English. The search yielded 655 articles, of which 63 were found to be eligible and retrieved as full-text articles for analysis. Bowel US showed 79.7% sensitivity and 96.7% specificity for the diagnosis of suspected CD, and 89% sensitivity and 94.3% specificity for initial assessment in established patients with CD. Bowel US identified ileal CD with 92.7% sensitivity, 88.2% specificity, and colon CD with 81.8% sensitivity, 95.3% specificity, with lower accuracy for detecting proximal lesions. The oral contrast agent improves the sensitivity and specificity in determining CD lesions and in assessing sites and extent. Bowel US is a tool for evaluation of CD lesions in terms of complications, postoperative recurrence, and monitoring response to medical therapy; it reliably detects postoperative recurrence and complications, as well as offers the possibility of monitoring disease progression.

  16. Front-loaded smear microscopy for the diagnosis of pulmonary TB in Tripoli, Libya.

    PubMed

    Gammo, Mohamed; Lamaric, Widad; Hadida, Mukhtar; Abuazza, Aida; Askar, Nabil A; Yassin, Mohammed A; Cuevas, Luis E

    2013-02-01

    Diagnosis of pulmonary TB by conventional smear microscopy requires patient attendance on 2 consecutive days. We investigated whether collecting sputum on-the-spot for smear microscopy on the day the patient presented was as sensitive and specific for diagnosis as the conventional spot-morning-spot scheme. We enrolled 412 adults who presented between January 2009 and October 2010 at the National Centre for TB Control in Tripoli, Libya, with cough of >2 weeks' duration, into a cross-sectional survey collecting four sputum specimens: on-the-spot and Xspot on Day 1; morning and on-the-spot on Day 2. 97 (24%) of 401 culture results were culture positive. Spot-Xspot and spot-morning smear microscopy had, respectively, 65% and 66% sensitivity and 97% and 96% specificity (p > 0.5). Spot-Xspot-morning and Spot-morning-spot smear-microscopy had, respectively, 67% and 66% sensitivity and 96% and 96% specificity (p > 0.5). For the diagnosis of pulmonary TB, the sensitivity and specificity of front-loaded (same-day) smear microscopy is similar to that of the standard smear microscopy scheme.

  17. Comparison of Established Diagnostic Methodologies and a Novel Bacterial smpB Real-Time PCR Assay for Specific Detection of Haemophilus influenzae Isolates Associated with Respiratory Tract Infections.

    PubMed

    Reddington, Kate; Schwenk, Stefan; Tuite, Nina; Platt, Gareth; Davar, Danesh; Coughlan, Helena; Personne, Yoann; Gant, Vanya; Enne, Virve I; Zumla, Alimuddin; Barry, Thomas

    2015-09-01

    Haemophilus influenzae is a significant causative agent of respiratory tract infections (RTI) worldwide. The development of a rapid H. influenzae diagnostic assay that would allow for the implementation of infection control measures and also improve antimicrobial stewardship for patients is required. A number of nucleic acid diagnostics approaches that detect H. influenzae in RTIs have been described in the literature; however, there are reported specificity and sensitivity limitations for these assays. In this study, a novel real-time PCR diagnostic assay targeting the smpB gene was designed to detect all serogroups of H. influenzae. The assay was validated using a panel of well-characterized Haemophilus spp. Subsequently, 44 Haemophilus clinical isolates were collected, and 36 isolates were identified as H. influenzae using a gold standard methodology that combined the results of matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) and a fucK diagnostic assay. Using the novel smpB diagnostic assay, 100% concordance was observed with the gold standard, demonstrating a sensitivity of 100% (95% confidence interval [CI], 90.26% to 100.00%) and a specificity of 100% (95% CI, 63.06% to 100.00%) when used on clinical isolates. To demonstrate the clinical utility of the diagnostic assay presented, a panel of lower RTI samples (n = 98) were blindly tested with the gold standard and smpB diagnostic assays. The results generated were concordant for 94/98 samples tested, demonstrating a sensitivity of 90.91% (95% CI, 78.33% to 97.47%) and a specificity of 100% (95% CI, 93.40% to 100.00%) for the novel smpB assay when used directly on respiratory specimens. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  18. Comparison of Established Diagnostic Methodologies and a Novel Bacterial smpB Real-Time PCR Assay for Specific Detection of Haemophilus influenzae Isolates Associated with Respiratory Tract Infections

    PubMed Central

    Reddington, Kate; Schwenk, Stefan; Tuite, Nina; Platt, Gareth; Davar, Danesh; Coughlan, Helena; Personne, Yoann; Gant, Vanya; Enne, Virve I.; Zumla, Alimuddin

    2015-01-01

    Haemophilus influenzae is a significant causative agent of respiratory tract infections (RTI) worldwide. The development of a rapid H. influenzae diagnostic assay that would allow for the implementation of infection control measures and also improve antimicrobial stewardship for patients is required. A number of nucleic acid diagnostics approaches that detect H. influenzae in RTIs have been described in the literature; however, there are reported specificity and sensitivity limitations for these assays. In this study, a novel real-time PCR diagnostic assay targeting the smpB gene was designed to detect all serogroups of H. influenzae. The assay was validated using a panel of well-characterized Haemophilus spp. Subsequently, 44 Haemophilus clinical isolates were collected, and 36 isolates were identified as H. influenzae using a gold standard methodology that combined the results of matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) and a fucK diagnostic assay. Using the novel smpB diagnostic assay, 100% concordance was observed with the gold standard, demonstrating a sensitivity of 100% (95% confidence interval [CI], 90.26% to 100.00%) and a specificity of 100% (95% CI, 63.06% to 100.00%) when used on clinical isolates. To demonstrate the clinical utility of the diagnostic assay presented, a panel of lower RTI samples (n = 98) were blindly tested with the gold standard and smpB diagnostic assays. The results generated were concordant for 94/98 samples tested, demonstrating a sensitivity of 90.91% (95% CI, 78.33% to 97.47%) and a specificity of 100% (95% CI, 93.40% to 100.00%) for the novel smpB assay when used directly on respiratory specimens. PMID:26109443

  19. Claims-Based Definition of Death in Japanese Claims Database: Validity and Implications

    PubMed Central

    Ooba, Nobuhiro; Setoguchi, Soko; Ando, Takashi; Sato, Tsugumichi; Yamaguchi, Takuhiro; Mochizuki, Mayumi; Kubota, Kiyoshi

    2013-01-01

    Background For the pending National Claims Database in Japan, researchers will not have access to death information in the enrollment files. We developed and evaluated a claims-based definition of death. Methodology/Principal Findings We used healthcare claims and enrollment data between January 2005 and August 2009 for 195,193 beneficiaries aged 20 to 74 in 3 private health insurance unions. We developed claims-based definitions of death using discharge or disease status and Charlson comorbidity index (CCI). We calculated sensitivity, specificity and positive predictive values (PPVs) using the enrollment data as a gold standard in the overall population and subgroups divided by demographic and other factors. We also assessed bias and precision in two example studies where an outcome was death. The definition based on the combination of discharge/disease status and CCI provided moderate sensitivity (around 60%) and high specificity (99.99%) and high PPVs (94.8%). In most subgroups, sensitivity of the preferred definition was also around 60% but varied from 28 to 91%. In an example study comparing death rates between two anticancer drug classes, the claims-based definition provided valid and precise hazard ratios (HRs). In another example study comparing two classes of anti-depressants, the HR with the claims-based definition was biased and had lower precision than that with the gold standard definition. Conclusions/Significance The claims-based definitions of death developed in this study had high specificity and PPVs while sensitivity was around 60%. The definitions will be useful in future studies when used with attention to the possible fluctuation of sensitivity in some subpopulations. PMID:23741526

  20. The pain drawing as an instrument for identifying cervical spine nerve involvement in chronic whiplash-associated disorders.

    PubMed

    Bernhoff, Gabriella; Landén Ludvigsson, Maria; Peterson, Gunnel; Bertilson, Bo Christer; Elf, Madeleine; Peolsson, Anneli

    2016-01-01

    The aim of the study was to investigate the psychometric properties of a standardized assessment of pain drawing with regard to clinical signs of cervical spine nerve root involvement. This cross-sectional study included data collected in a randomized controlled study. Two hundred and sixteen patients with chronic (≥6 months) whiplash-associated disorders, grade 2 or 3, were included in this study. The validity, sensitivity, and specificity of a standardized pain drawing assessment for determining nerve root involvement were analyzed, compared to the clinical assessment. In addition, we analyzed the interrater reliability with 50 pain drawings. Agreement was poor between the standardized pain drawing assessment and the clinical assessment (kappa =0.11, 95% CI: -0.03 to 0.20). Sensitivity was high (93%), but specificity was low (19%). Interrater reliability was good (kappa =0.64, 95% CI: 0.53 to 0.76). The standardized pain drawing assessment of nerve root involvement in chronic whiplash-associated disorders was not in agreement with the clinical assessment. Further research is warranted to optimize the utilization of a pain/discomfort drawing as a supportive instrument for identifying nerve involvement in cervical spinal injuries.

  1. Comparative Study of GeneXpert with ZN Stain and Culture in Samples of Suspected Pulmonary Tuberculosis

    PubMed Central

    Bajaj, Ashish; Bhatia, Vinay; Dutt, Sarjana

    2016-01-01

    Introduction Tuberculosis remains one of the deadliest communicable diseases. There are number of tests available for the diagnosis of tuberculosis but conventional microscopy has low sensitivity and culture although gold standard, but takes longer time for positivity. On the other side, Nucleic acid amplification techniques due to its rapidity and sensitivity not only help in early diagnosis and management of tuberculosis especially in patients with high clinical suspicion like immunocompromised patients, history of contact with active tuberculosis patient etc., but also curtail the transmission of the disease. Aim To evaluate the sensitivity, specificity, positive predictive value and negative predictive value of Nucleic acid amplification assay (GeneXpert) using respiratory samples in patients with suspected pulmonary tuberculosis and compare with AFB smear microscopy (Ziehl Neelsen stain) and Acid Fast Bacilli (AFB) culture. Materials and Methods We retrospectively reviewed the respiratory samples of suspected pulmonary tuberculosis (including Bronchoalveolar lavage and sputum) of 170 patients from Jan 2015 to Nov 2015 for ZN stain, culture and GeneXpert (Xpert® MTB/Rif assay). The sensitivity, specificity, PPV and NPV of GeneXpert and ZN microscopy were calculated using Liquid culture of Mycobacterium tuberculosis as gold standard. Results A total of 170 patient samples were evaluated in final analysis. Of these, 14 samples were positive by all three methods used in our study. The overall sensitivity, specificity, PPV and NPV of GeneXpert were 86.8%, 93.1%, 78.5% and 96% respectively and for BAL sample, 81.4%, 93.4%, 73.3% and 95.7% respectively. The overall sensitivity and specificity of AFB smear microscopy were 22.2%, % and 78.5% respectively and for BAL sample 22.2% and 100% respectively. For AFB negative samples sensitivity and specificity were 79.1% and 93.1% respectively. Conclusion GeneXpert has a higher sensitivity than AFB smear microscopy in respiratory samples. GeneXpert can be a useful tool for early diagnosis of patients with high clinical suspicion of pulmonary tuberculosis. Positive GeneXpert, but culture negative results should be read cautiously and be well correlated with clinical and treatment history of the patient. The other major advantage of Gene Xpert is that it simultaneously detects Rifampicin resistance and especially beneficial in patient with MDR and HIV associated tuberculosis and should be studied further. PMID:27437212

  2. Sensitivity and specificity of the Eating Assessment Tool and the Volume-Viscosity Swallow Test for clinical evaluation of oropharyngeal dysphagia.

    PubMed

    Rofes, L; Arreola, V; Mukherjee, R; Clavé, P

    2014-09-01

    Oropharyngeal dysphagia (OD) is an underdiagnosed digestive disorder that causes severe nutritional and respiratory complications. Our aim was to determine the accuracy of the Eating Assessment Tool (EAT-10) and the Volume-Viscosity Swallow Test (V-VST) for clinical evaluation of OD. We studied 120 patients with swallowing difficulties and 14 healthy subjects. OD was evaluated by the 10-item screening questionnaire EAT-10 and the bedside method V-VST, videofluoroscopy (VFS) being the reference standard. The V-VST is an effort test that uses boluses of different volumes and viscosities to identify clinical signs of impaired efficacy (impaired labial seal, piecemeal deglutition, and residue) and impaired safety of swallow (cough, voice changes, and oxygen desaturation ≥3%). Discriminating ability was assessed by the AUC of the ROC curve and sensitivity and specificity values. According to VFS, prevalence of OD was 87%, 75.6% with impaired efficacy and 80.9% with impaired safety of swallow including 17.6% aspirations. The EAT-10 showed a ROC AUC of 0.89 for OD with an optimal cut-off at 2 (0.89 sensitivity and 0.82 specificity). The V-VST showed 0.94 sensitivity and 0.88 specificity for OD, 0.79 sensitivity and 0.75 specificity for impaired efficacy, 0.87 sensitivity and 0.81 specificity for impaired safety, and 0.91 sensitivity and 0.28 specificity for aspirations. Clinical methods for screening (EAT-10) and assessment (V-VST) of OD offer excellent psychometric proprieties that allow adequate management of OD. Their universal application among at-risk populations will improve the identification of patients with OD at risk for malnutrition and aspiration pneumonia. © 2014 The Authors. Neurogastroenterology & Motility published by John Wiley & Sons Ltd.

  3. Validation of the colour difference plot scoring system analysis of the 103 hexagon multifocal electroretinogram in the evaluation of hydroxychloroquine retinal toxicity.

    PubMed

    Graves, Gabrielle S; Adam, Murtaza K; Stepien, Kimberly E; Han, Dennis P

    2014-08-01

    To evaluate sensitivity, specificity and reproducibility of colour difference plot analysis (CDPA) of 103 hexagon multifocal electroretinogram (mfERG) in detecting established hydroxychloroquine (HCQ) retinal toxicity. Twenty-three patients taking HCQ were divided into those with and without retinal toxicity and were compared with a control group without retinal disease and not taking HCQ. CDPA with two masked examiners was performed using age-corrected mfERG responses in the central ring (Rc ; 0-5.5 degrees from fixation) and paracentral ring (Rp ; 5.5-11 degrees from fixation). An abnormal ring was defined as containing any hexagons with a difference in two or more standard deviations from normal (colour blue or black). Categorical analysis (ring involvement or not) showed Rc had 83% sensitivity and 93% specificity. Rp had 89% sensitivity and 82% specificity. Requiring abnormal hexagons in both Rc and Rp yielded sensitivity and specificity of 83% and 95%, respectively. If required in only one ring, they were 89% and 80%, respectively. In this population, there was complete agreement in identifying toxicity when comparing CDPA using Rp with ring ratio analysis using R5/R4 P1 ring responses (89% sensitivity and 95% specificity). Continuous analysis of CDPA with receiver operating characteristic analysis showed optimized detection (83% sensitivity and 96% specificity) when ≥4 abnormal hexagons were present anywhere within the Rp ring outline. Intergrader agreement and reproducibility were good. Colour difference plot analysis had sensitivity and specificity that approached that of ring ratio analysis of R5/R4 P₁ responses. Ease of implementation and reproducibility are notable advantages of CDPA. © 2014 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  4. Sensitivity and specificity of the Eating Assessment Tool and the Volume-Viscosity Swallow Test for clinical evaluation of oropharyngeal dysphagia

    PubMed Central

    Rofes, L; Arreola, V; Mukherjee, R; Clavé, P

    2014-01-01

    Background Oropharyngeal dysphagia (OD) is an underdiagnosed digestive disorder that causes severe nutritional and respiratory complications. Our aim was to determine the accuracy of the Eating Assessment Tool (EAT-10) and the Volume-Viscosity Swallow Test (V-VST) for clinical evaluation of OD. Methods We studied 120 patients with swallowing difficulties and 14 healthy subjects. OD was evaluated by the 10-item screening questionnaire EAT-10 and the bedside method V-VST, videofluoroscopy (VFS) being the reference standard. The V-VST is an effort test that uses boluses of different volumes and viscosities to identify clinical signs of impaired efficacy (impaired labial seal, piecemeal deglutition, and residue) and impaired safety of swallow (cough, voice changes, and oxygen desaturation ≥3%). Discriminating ability was assessed by the AUC of the ROC curve and sensitivity and specificity values. Key Results According to VFS, prevalence of OD was 87%, 75.6% with impaired efficacy and 80.9% with impaired safety of swallow including 17.6% aspirations. The EAT-10 showed a ROC AUC of 0.89 for OD with an optimal cut-off at 2 (0.89 sensitivity and 0.82 specificity). The V-VST showed 0.94 sensitivity and 0.88 specificity for OD, 0.79 sensitivity and 0.75 specificity for impaired efficacy, 0.87 sensitivity and 0.81 specificity for impaired safety, and 0.91 sensitivity and 0.28 specificity for aspirations. Conclusions & Inferences Clinical methods for screening (EAT-10) and assessment (V-VST) of OD offer excellent psychometric proprieties that allow adequate management of OD. Their universal application among at-risk populations will improve the identification of patients with OD at risk for malnutrition and aspiration pneumonia. PMID:24909661

  5. Screening for emotional disorders in patients with cancer using the Brief Symptom Inventory (BSI) and the BSI-18 versus a standardized psychiatric interview (the World Health Organization Composite International Diagnostic Interview).

    PubMed

    Grassi, Luigi; Caruso, Rosangela; Mitchell, Alex J; Sabato, Silvana; Nanni, Maria Giulia

    2018-06-01

    Given the adverse consequences of psychiatric and psychosocial morbidity on the quality of life for patients with cancer, prompt detection of psychological symptoms is mandatory. The authors examined the properties and accuracy of the Brief Symptom Inventory (the 53-item version [BSI] and the 18-item version [BSI-18]) for the detection of psychiatric morbidity compared with the World Health Organization Composite International Diagnostic Interview (CIDI) for International Classification of Diseases-10th Revision psychiatric diagnoses. A convenience sample of 498 patients with newly diagnosed cancer who were recruited in cancer outpatient services participated in the CIDI interview and in BSI and BSI-18 assessments. The prevalence of psychiatric morbidity was 39.75%. When participants were classified as cases using the BSI standard case rule, agreement with the CIDI was potentially acceptable (sensitivity, 72.7%; specificity, 88.7%). In contrast, the accuracy of the BSI-18 in identifying cases was poor according to the standard case rule, with very low sensitivity (29.3%) (misclassification rate, 28.7%). By using a first alternative case-rule system (a BSI-18 global severity index [GSI] T-score ≥57), sensitivity marginally improved (45%), whereas a second alternative case-rule system (a GSI T-score ≥50) significantly increased sensitivity (77.3%). In receiver operating characteristic curve analysis, a further cutoff GSI T-score ≥48 exhibited good discrimination levels (sensitivity, 82.3%; specificity, 72.4%). There were some differences in GSI cutoff T-scores according to the International Classification of Diseases-10th Revision diagnosis and sex. The BSI appeared to have acceptable diagnostic accuracy compared with a standardized psychiatric interview. For the BSI-18, it is mandatory to use alternative case-rule systems, to identify patients with psychiatric morbidity. Cancer 2018;124:2415-26. © 2018 American Cancer Society. © 2018 American Cancer Society.

  6. Performance Assessment of Internal Quality Control (IQC) Products in Blood Transfusion Compatibility Testing in China

    PubMed Central

    Li, Jing-Jing; Gao, Qi; Liu, Zhi-Dong; Kang, Qiong-Hua; Hou, Yi-Jun; Zhang, Luo-Chuan; Hu, Xiao-Mei; Li, Jie; Zhang, Juan

    2015-01-01

    Internal quality control (IQC) is a critical component of laboratory quality management, and IQC products can determine the reliability of testing results. In China, given the fact that most blood transfusion compatibility laboratories do not employ IQC products or do so minimally, there is a lack of uniform and standardized IQC methods. To explore the reliability of IQC products and methods, we studied 697 results from IQC samples in our laboratory from 2012 to 2014. The results showed that the sensitivity and specificity of the IQCs in anti-B testing were 100% and 99.7%, respectively. The sensitivity and specificity of the IQCs in forward blood typing, anti-A testing, irregular antibody screening, and cross-matching were all 100%. The reliability analysis indicated that 97% of anti-B testing results were at a 99% confidence level, and 99.9% of forward blood typing, anti-A testing, irregular antibody screening, and cross-matching results were at a 99% confidence level. Therefore, our IQC products and methods are highly sensitive, specific, and reliable. Our study paves the way for the establishment of a uniform and standardized IQC method for pre-transfusion compatibility testing in China and other parts of the world. PMID:26488582

  7. Identification of the need for home visiting nurse: development of a new assessment tool

    PubMed Central

    Taguchi, Atsuko; Nagata, Satoko; Naruse, Takashi; Kuwahara, Yuki; Yamaguchi, Takuhiro; Murashima, Sachiyo

    2014-01-01

    Objective To develop a Home Visiting Nursing Service Need Assessment Form (HVNS-NAF) to standardize the decision about the need for home visiting nursing service. Methods The sample consisted of older adults who had received coordinated services by care managers. We defined the need for home visiting nursing service by elderly individuals as the decision of the need by a care manager so that the elderly can continue to live independently. Explanatory variables included demographic factors, medical procedure, severity of illness, and caregiver variables. Multiple logistic regression was carried out after univariate analyses to decide the variables to include and the weight of each variable in the HVNS-NAF. We then calculated the sensitivity and specificity of each cutoff value, and defined the score with the highest sensitivity and specificity as the cutoff value. Results Nineteen items were included in the final HVNS-NAF. When the cutoff value was 2 points, the sensitivity was 77.0%, specificity 68.5%, and positive predictive value 56.8%. Conclusions HVNS-NAF is the first validated standard based on characteristics of elderly clients who required home visiting nursing service. Using the HVNS-NAF may result in reducing the unmet need for home visiting nursing service and preventing hospitalization. PMID:24665229

  8. [How good are clinical investigative procedures for diagnosing meniscus lesions?].

    PubMed

    Jerosch, J; Riemer, S

    2004-06-01

    The purpose of this study was to evaluate different clinical meniscus tests. During 13 months we evaluated 64 patients with a suspected meniscus lesion in a prospective study. The age ranged from 16 to 76 years (average: 38.5 years). 66 % were male patients. Between the clinical examination and the arthroscopy there was no additional trauma to the knee. All patients were clinically examined in a standard manner by two independent orthopaedic surgeons. Clinical findings of the menisci were documented according to 12 well-described and commonly used meniscus tests. The arthroscopy was performed by a single surgeon who was not aware of the results of the clinical examination. This surgeon documented the intraarticular findings in a standardized operating report. A meniscus lesion/degeneration was documented when this was evident either by inspection or by palpation. The results showed either clinical meniscus tests with a high specificity and a low sensitivity or tests with a high sensitivity, but only a low specificity. We were not able to identify meniscus tests which showed both a high sensitivity and a high specificity. Even with access to MRI the clinical findings in knee joint with injured menisci still have a high diagnostic value. However, it seems to be necessary to combine different tests.

  9. Nested-PCR and a new ELISA-based NovaLisa test kit for malaria diagnosis in an endemic area of Thailand.

    PubMed

    Thongdee, Pimwan; Chaijaroenkul, Wanna; Kuesap, Jiraporn; Na-Bangchang, Kesara

    2014-08-01

    Microscopy is considered as the gold standard for malaria diagnosis although its wide application is limited by the requirement of highly experienced microscopists. PCR and serological tests provide efficient diagnostic performance and have been applied for malaria diagnosis and research. The aim of this study was to investigate the diagnostic performance of nested PCR and a recently developed an ELISA-based new rapid diagnosis test (RDT), NovaLisa test kit, for diagnosis of malaria infection, using microscopic method as the gold standard. The performance of nested-PCR as a malaria diagnostic tool is excellent with respect to its high accuracy, sensitivity, specificity, and ability to discriminate Plasmodium species. The sensitivity and specificity of nested-PCR compared with the microscopic method for detection of Plasmodium falciparum, Plasmodium vivax, and P. falciparum/P. vivax mixed infection were 71.4 vs 100%, 100 vs 98.7%, and 100 vs 95.0%, respectively. The sensitivity and specificity of the ELISA-based NovaLisa test kit compared with the microscopic method for detection of Plasmodium genus were 89.0 vs 91.6%, respectively. NovaLisa test kit provided comparable diagnostic performance. Its relatively low cost, simplicity, and rapidity enables large scale field application.

  10. Diagnostic utility of a line probe assay for multidrug resistant-TB in smear-negative pulmonary tuberculosis.

    PubMed

    Singh, Binit Kumar; Sharma, Surendra K; Sharma, Rohini; Sreenivas, Vishnubhatla; Myneedu, Vithal P; Kohli, Mikashmi; Bhasin, Dinkar; Sarin, Sanjay

    2017-01-01

    To evaluate the performance of Genotype MTBDRplus VER 2.0 in the diagnosis of Mycobacterium tuberculosis (MTB) in sputum smear-negative pulmonary TB cases. A total of 572 Ziehl-Neelsen sputum smear-negative samples were selected and subjected to line probe assay (Genotype MTBDRplus VER 2.0), and culture in mycobacterial growth indicator tube (MGIT-960). Immunochromatographic test was used to confirm the MTB-complex (MTBC) in culture-positive samples and phenotypic drug-susceptibility testing was done using MGIT-960. The line probe assay was able to diagnose MTBC in 38.2% (213/558) of specimens after excluding 14 nontuberculous mycobacteria. Sensitivity and specificity of the assay were 68.4% and 89.3% respectively, considering MGIT-960 culture as gold standard after excluding contaminated and invalid results. On comparing with composite reference standard, the assay had 71.5% sensitivity and 100% specificity in the diagnosis of tuberculosis. The sensitivity and specificity for detecting resistance to rifampicin (RMP) were 100% and 99.24% respectively and for resistance to isoniazid (INH) were 97.62% and 98.55%, respectively. Genotype MTBDRplus VER 2.0 is a rapid and precise diagnostic tool for detection of MTB in sputum smear-negative samples. It also facilitates accurate diagnosis of RMP and INH resistance within turn around-time.

  11. The Quantitative Science of Evaluating Imaging Evidence.

    PubMed

    Genders, Tessa S S; Ferket, Bart S; Hunink, M G Myriam

    2017-03-01

    Cardiovascular diagnostic imaging tests are increasingly used in everyday clinical practice, but are often imperfect, just like any other diagnostic test. The performance of a cardiovascular diagnostic imaging test is usually expressed in terms of sensitivity and specificity compared with the reference standard (gold standard) for diagnosing the disease. However, evidence-based application of a diagnostic test also requires knowledge about the pre-test probability of disease, the benefit of making a correct diagnosis, the harm caused by false-positive imaging test results, and potential adverse effects of performing the test itself. To assist in clinical decision making regarding appropriate use of cardiovascular diagnostic imaging tests, we reviewed quantitative concepts related to diagnostic performance (e.g., sensitivity, specificity, predictive values, likelihood ratios), as well as possible biases and solutions in diagnostic performance studies, Bayesian principles, and the threshold approach to decision making. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  12. Measures of accuracy and performance of diagnostic tests.

    PubMed

    Drobatz, Kenneth J

    2009-05-01

    Diagnostic tests are integral to the practice of veterinary cardiology, any other specialty, and general veterinary medicine. Developing and understanding diagnostic tests is one of the cornerstones of clinical research. This manuscript describes the diagnostic test properties including sensitivity, specificity, predictive value, likelihood ratio, receiver operating characteristic curve. Review of practical book chapters and standard statistics manuscripts. Diagnostics such as sensitivity, specificity, predictive value, likelihood ratio, and receiver operating characteristic curve are described and illustrated. Basic understanding of how diagnostic tests are developed and interpreted is essential in reviewing clinical scientific papers and understanding evidence based medicine.

  13. Diagnostic Performance of CT for Diagnosis of Fat-Poor Angiomyolipoma in Patients With Renal Masses: A Systematic Review and Meta-Analysis.

    PubMed

    Woo, Sungmin; Suh, Chong Hyun; Cho, Jeong Yeon; Kim, Sang Youn; Kim, Seung Hyup

    2017-11-01

    The purpose of this article is to systematically review and perform a meta-analysis of the diagnostic performance of CT for diagnosis of fat-poor angiomyolipoma (AML) in patients with renal masses. MEDLINE and EMBASE were systematically searched up to February 2, 2017. We included diagnostic accuracy studies that used CT for diagnosis of fat-poor AML in patients with renal masses, using pathologic examination as the reference standard. Two independent reviewers assessed the methodologic quality using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. Sensitivity and specificity of included studies were calculated and were pooled and plotted in a hierarchic summary ROC plot. Sensitivity analyses using several clinically relevant covariates were performed to explore heterogeneity. Fifteen studies (2258 patients) were included. Pooled sensitivity and specificity were 0.67 (95% CI, 0.48-0.81) and 0.97 (95% CI, 0.89-0.99), respectively. Substantial and considerable heterogeneity was present with regard to sensitivity and specificity (I 2 = 91.21% and 78.53%, respectively). At sensitivity analyses, the specificity estimates were comparable and consistently high across all subgroups (0.93-1.00), but sensitivity estimates showed significant variation (0.14-0.82). Studies using pixel distribution analysis (n = 3) showed substantially lower sensitivity estimates (0.14; 95% CI, 0.04-0.40) compared with the remaining 12 studies (0.81; 95% CI, 0.76-0.85). CT shows moderate sensitivity and excellent specificity for diagnosis of fat-poor AML in patients with renal masses. When methods other than pixel distribution analysis are used, better sensitivity can be achieved.

  14. Computed Tomography-Derived Fractional Flow Reserve in the Detection of Lesion-Specific Ischemia: An Integrated Analysis of 3 Pivotal Trials.

    PubMed

    Xu, Rende; Li, Chenguang; Qian, Juying; Ge, Junbo

    2015-11-01

    Invasive fractional flow reserve (FFR) is the gold standard for the determination of physiologic stenosis severity and the need for revascularization. FFR computed from standard acquired coronary computed tomographic angiography datasets (FFRCT) is an emerging technology which allows calculation of FFR using resting image data from coronary computed tomographic angiography (CCTA). However, the diagnostic accuracy of FFRCT in the evaluation of lesion-specific myocardial ischemia remains to be confirmed, especially in patients with intermediate coronary stenosis. We performed an integrated analysis of data from 3 prospective, international, and multicenter trials, which assessed the diagnostic performance of FFRCT using invasive FFR as a reference standard. Three studies evaluating 609 patients and 1050 vessels were included. The total calculated sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of FFRCT were 82.8%, 77.7%, 60.8%, 91.6%, and 79.2%, respectively, for the per-vessel analysis, and 89.4%, 70.5%, 69.7%, 89.7%, and 78.7%, respectively, for the per-patient analysis. Compared with CCTA alone, FFRCT demonstrated significantly improved accuracy (P < 0.001) in detecting lesion-specific ischemia. In patients with intermediate coronary stenosis, FFRCT remained both highly sensitive and specific with respect to the diagnosis of ischemia. In conclusion, FFRCT appears to be a reliable noninvasive alternative to invasive FFR, as it demonstrates high accuracy in the determination of anatomy and lesion-specific ischemia, which justifies the performance of additional randomized controlled trials to evaluate both the clinical benefits and the cost-effectiveness of FFRCT-guided coronary revascularization.

  15. MPT64 antigen detection test improves routine diagnosis of extrapulmonary tuberculosis in a low-resource setting: A study from the tertiary care hospital in Zanzibar.

    PubMed

    Jørstad, Melissa Davidsen; Marijani, Msafiri; Dyrhol-Riise, Anne Ma; Sviland, Lisbet; Mustafa, Tehmina

    2018-01-01

    Extrapulmonary tuberculosis (EPTB) is a diagnostic challenge. An immunochemistry-based MPT64 antigen detection test (MPT64 test) has reported higher sensitivity in the diagnosis of EPTB compared with conventional methods. The objective of this study was to implement and evaluate the MPT64 test in routine diagnostics in a low-resource setting. Patients with presumptive EPTB were prospectively enrolled at Mnazi Mmoja Hospital, Zanzibar, and followed to the end of treatment. Specimens collected were subjected to routine diagnostics, GeneXpert® MTB/RIF assay and the MPT64 test. The performance of the MPT64 test was assessed using a composite reference standard, defining the patients as tuberculosis (TB) cases or non-TB cases. Patients (n = 132) were classified as confirmed TB (n = 12), probable TB (n = 34), possible TB (n = 18), non-TB (n = 62) and uncategorized (n = 6) cases. Overall, in comparison to the composite reference standard for diagnosis, the sensitivity, specificity, positive predictive value, negative predictive value and accuracy of the MPT64 test was 69%, 95%, 94%, 75% and 82%, respectively. The MPT64 test performance was best in TB lymphadenitis cases (n = 67, sensitivity 79%, specificity 97%) and in paediatric TB (n = 41, sensitivity 100%, specificity 96%). We show that the MPT64 test can be implemented in routine diagnostics in a low-resource setting and improves the diagnosis of EPTB, especially in TB lymphadenitis and in children.

  16. Diagnostic accuracy of tuberculous lymphadenitis fine needle aspiration biopsy confirmed by PCR as gold standard

    NASA Astrophysics Data System (ADS)

    DSuryadi; Delyuzar; Soekimin

    2018-03-01

    Indonesia is the second country with the TB (tuberculosis) burden in the world. Improvement in controlling TB and reducing the complications can accelerate early diagnosis and correct treatment. PCR test is a gold standard. However, it is quite expensive for routine diagnosis. Therefore, an accurate and cheaper diagnostic method such as fine needle aspiration biopsy is needed. The study aimsto determine the accuracy of fine needle aspiration biopsy cytology in the diagnosis of tuberculous lymphadenitis. A cross-sectional analytic study was conducted to the samples from patients suspected with tuberculous lymphadenitis. The fine needle aspiration biopsy (FNAB)test was performed and confirmed by PCR test.There is a comparison to the sensitivity, specificity, accuracy, positive predictive value and negative predictive value of both methods. Sensitivity (92.50%), specificity (96.49%), accuracy (94.85%), positive predictive value (94.87%) and negative predictive value (94.83%) were in FNAB test compared to gold standard. We concluded that fine needle aspiration biopsy is a recommendation for a cheaper and accurate diagnostic test for tuberculous lymphadenitis diagnosis.

  17. Deciphering the Sensitivity and Specificity of the Implantable Doppler in Free Flap Monitoring.

    PubMed

    Chang, Edward I; Ibrahim, Amir; Zhang, Hong; Liu, Jun; Nguyen, Alexander T; Reece, Gregory P; Yu, Peirong

    2015-11-19

    The efficacy of implantable Dopplers (iD) remains an area of considerable debate. Our study aims to decipher the sensitivity and specificity of the iD for free flap monitoring. A retrospective review of all free flaps with an iD was performed between 2000-2012. A Cook-Swartz iD was used in 439 patients (head and neck: n=364, breast: n=53, and extremity: n=22), and demonstrated equivalent sensitivity and specificity between flap types. The overall sensitivity and specificity was 77.8% and 88.4% respectively. The iD was placed on the artery in 267 patients, the vein in 101 patients, and 71 patients had a Doppler placed on both the artery and vein with significantly greater specificity for monitoring the artery than the vein (94.2% vs. 74.0%, p<0.001), but no difference between monitoring both the artery and the vein. Venous monitoring was significantly associated with a takeback (OR: 3.17, CI: 1.70-5.91; p=0.0003). There were 284 flaps that also had a monitoring segment in addition to the iD which significantly increased specificity for microvascular complications (OR: 17.71, CI: 3.39-92.23; p=0.0006). The specificity (90.5% vs. 84.8%) and sensitivity (80.0% vs. 66.7%) were significantly higher for clinically monitored flaps. The takeback rate was 13.0%, with positive findings in 59.6%, and 5.2% total flap loss. The use of implantable Dopplers has high sensitivity and specificity for buried free flap despite positive findings in less than 60% of take backs. Monitoring the artery is preferable to the vein, but clinical exam remains the gold standard for flap monitoring.

  18. Deciphering the Sensitivity and Specificity of the Implantable Doppler Probe in Free Flap Monitoring.

    PubMed

    Chang, Edward I; Ibrahim, Amir; Zhang, Hong; Liu, Jun; Nguyen, Alexander T; Reece, Gregory P; Yu, Peirong

    2016-03-01

    The efficacy of implantable Doppler probes remains an area of considerable debate. This study aims to decipher its sensitivity and specificity for free flap monitoring. A retrospective review of all free flaps with an implantable Doppler probe was performed between 2000 and 2012. A Cook-Swartz implantable Doppler probe was used in 439 patients (head and neck, n = 364; breast, n = 53; extremity, n = 22), and demonstrated equivalent sensitivity and specificity between flap types. The overall sensitivity and specificity were 77.8 percent and 88.4 percent, respectively. The artery was monitored in 267 patients, compared to venous monitoring in 101 patients, and in 71 patients both the artery and vein were monitored. Arterial monitoring had significantly greater specificity than venous monitoring, (94.2 percent versus 74.0 percent; p < 0.001), but no benefit was found in monitoring both the artery and the vein. Venous monitoring was significantly associated with reoperation (OR, 3.17; 95 percent CI, 1.70 to 5.91; p = 0.0003). There were 284 flaps that had a monitoring segment in addition to the implantable Doppler probe that significantly increased overall specificity for microvascular complications (OR, 17.71; 95 percent CI, 3.39 to 92.23; p = 0.0006). The specificity (90.5 percent versus 84.8 percent) and sensitivity (80.0 percent versus 66.7 percent) were significantly higher for clinically monitored flaps. The take-back rate was 13.0 percent, with positive findings in 59.6 percent, and 5.2 percent total flap loss. The use of implantable Doppler probes has high sensitivity and specificity for buried free flaps despite positive findings in less than 60 percent of take-backs. Monitoring the artery is recommended, but clinical examination remains the gold standard for flap monitoring. Diagnostic, IV.

  19. HPV Genotyping of Modified General Primer-Amplicons Is More Analytically Sensitive and Specific by Sequencing than by Hybridization

    PubMed Central

    Meisal, Roger; Rounge, Trine Ballestad; Christiansen, Irene Kraus; Eieland, Alexander Kirkeby; Worren, Merete Molton; Molden, Tor Faksvaag; Kommedal, Øyvind; Hovig, Eivind; Leegaard, Truls Michael

    2017-01-01

    Sensitive and specific genotyping of human papillomaviruses (HPVs) is important for population-based surveillance of carcinogenic HPV types and for monitoring vaccine effectiveness. Here we compare HPV genotyping by Next Generation Sequencing (NGS) to an established DNA hybridization method. In DNA isolated from urine, the overall analytical sensitivity of NGS was found to be 22% higher than that of hybridization. NGS was also found to be the most specific method and expanded the detection repertoire beyond the 37 types of the DNA hybridization assay. Furthermore, NGS provided an increased resolution by identifying genetic variants of individual HPV types. The same Modified General Primers (MGP)-amplicon was used in both methods. The NGS method is described in detail to facilitate implementation in the clinical microbiology laboratory and includes suggestions for new standards for detection and calling of types and variants with improved resolution. PMID:28045981

  20. HPV Genotyping of Modified General Primer-Amplicons Is More Analytically Sensitive and Specific by Sequencing than by Hybridization.

    PubMed

    Meisal, Roger; Rounge, Trine Ballestad; Christiansen, Irene Kraus; Eieland, Alexander Kirkeby; Worren, Merete Molton; Molden, Tor Faksvaag; Kommedal, Øyvind; Hovig, Eivind; Leegaard, Truls Michael; Ambur, Ole Herman

    2017-01-01

    Sensitive and specific genotyping of human papillomaviruses (HPVs) is important for population-based surveillance of carcinogenic HPV types and for monitoring vaccine effectiveness. Here we compare HPV genotyping by Next Generation Sequencing (NGS) to an established DNA hybridization method. In DNA isolated from urine, the overall analytical sensitivity of NGS was found to be 22% higher than that of hybridization. NGS was also found to be the most specific method and expanded the detection repertoire beyond the 37 types of the DNA hybridization assay. Furthermore, NGS provided an increased resolution by identifying genetic variants of individual HPV types. The same Modified General Primers (MGP)-amplicon was used in both methods. The NGS method is described in detail to facilitate implementation in the clinical microbiology laboratory and includes suggestions for new standards for detection and calling of types and variants with improved resolution.

  1. A systematic review and meta-analysis of the diagnostic accuracy of point-of-care tests for the detection of hyperketonemia in dairy cows.

    PubMed

    Tatone, Elise H; Gordon, Jessica L; Hubbs, Jessie; LeBlanc, Stephen J; DeVries, Trevor J; Duffield, Todd F

    2016-08-01

    Several rapid tests for use on farm have been validated for the detection of hyperketonemia (HK) in dairy cattle, however the reported sensitivity and specificity of each method varies and no single study has compared them all. Meta-analysis of diagnostic test accuracy is becoming more common in human medical literature but there are few veterinary examples. The objective of this work was to perform a systematic review and meta-analysis to determine the point-of-care testing method with the highest combined sensitivity and specificity, the optimal threshold for each method, and to identify gaps in the literature. A comprehensive literature search resulted in 5196 references. After removing duplicates and performing relevance screening, 23 studies were included for the qualitative synthesis and 18 for the meta-analysis. The three index tests evaluated in the meta-analysis were: the Precision Xtra(®) handheld device measuring beta-hydroxybutyrate (BHB) concentration in whole blood, and Ketostix(®) and KetoTest(®) semi-quantitative strips measuring the concentration of acetoacetate in urine and BHB in milk, respectively. The diagnostic accuracy of the 3 index tests relative to the reference standard measurement of BHB in serum or whole blood between 1.0-1.4mmol/L was compared using the hierarchical summary receiver operator characteristic (HSROC) method. Subgroup analysis was conducted for each index test to examine the accuracy at different thresholds. The impact of the reference standard threshold, the reference standard method, the prevalence of HK in the population, the primary study source and risk of bias of the primary study was explored using meta-regression. The Precision Xtra(®) device had the highest summary sensitivity in whole blood BHB at 1.2mmol/L, 94.8% (CI95%: 92.6-97.0), and specificity, 97.5% (CI95%: 96.9-98.1). The threshold employed (1.2-1.4mmol/L) did not impact the diagnostic accuracy of the test. The Ketostix(®) and KetoTest(®) strips had the highest summary sensitivity and specificity when the trace and weak positive thresholds were used, respectively. Controlling for the source of publication, HK prevalence and reference standard employed did not impact the estimated sensitivity and specificity of the tests. Including only peer-reviewed studies reduced the number of primary studies evaluating the Precision Xtra(®) by 43% and Ketostix(®) by 33%. Diagnosing HK with blood, urine or milk are valid options, however, the diagnostic inaccuracy of urine and milk should be considered when making economic and treatment decisions. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Detection of pericardial effusion by chest roentgenography and electrocardiography versus echocardiography.

    PubMed Central

    Manyari, D. E.; Milliken, J. A.; Colwell, B. T.; Burggraf, G. W.

    1978-01-01

    To determine the sensitivity and specificity of chest roentgenography and electrocardiography in the detection of pericardial effusion, echocardiography was used as the diagnostic standard. Chest roentgenograms and electrocardiograms of 124 patients, 57 of whom had pericardial effusion, were read without knowledge of the echocardiographic interpretation. The sensitivity of roentgenographic diagnosis was low (20%), as was that of diagnosis from decreased voltage on the electrocardiogram (26%). The specificity of the chest roentgenogram was 89% and that of the low-voltage electrocardiogram 97%. The high specificity of the low-voltage electrocardiogram may have been due in part to the exclusion of obese and emphysematous subjects from the study. When cardiomegaly detected roentgenographically or a low-voltage electrocardiogram or both were considered as evidence of pericardial effusion, sensitivity improved to 82% but specificity declined to 29%. It is concluded the chest roentgenography and electrocardiography are unsatisfactory as screening investigations for the detection of pericardial effusion. Images FIG. 1 FIG. 2 FIG. 3 PMID:688146

  3. Serodiagnosis of bovine leptospirosis by IgG-enzyme-linked immunosorbent assay and latex agglutination test.

    PubMed

    Senthilkumar, T M A; Subathra, M; Ramadass, P; Ramaswamy, V

    2010-02-01

    The efficacy of a recombinant leptospiral outer membrane protein LipL41 as an antigen for conducting IgG-Enzyme linked immunosorbent assay (ELISA) and latex agglutination test (LAT) for serodiagnosis of bovine leptospirosis was evaluated. The recombinant LipL41 antigen developed and used for detecting the antibodies was specific in detection of the pathogenic serovars of Leptospira, as the expression of the LipL41 antigen is restricted only to pathogenic leptospires. A total of 430 bovine serum samples were subjected to IgG-ELISA and LAT, and the sensitivity and specificity were assessed in comparison with microscopic agglutination test (MAT). The sensitivity and specificity of IgG-ELISA and LAT were 86.84% and 93.16%, and 95.42% and 98.33% respectively. Both the tests are found to be sensitive, specific and concurred with the standard MAT. The study concluded that the rLipL41 protein could be used as a potential diagnostic antigen in different assay formats for bovine leptospirosis.

  4. Development of duplex real-time PCR for the detection of WSSV and PstDV1 in cultivated shrimp.

    PubMed

    Leal, Carlos A G; Carvalho, Alex F; Leite, Rômulo C; Figueiredo, Henrique C P

    2014-07-05

    The White spot syndrome virus (WSSV) and Penaeus stylirostris penstyldensovirus 1 (previously named Infectious hypodermal and hematopoietic necrosis virus-IHHNV) are two of the most important viral pathogens of penaeid shrimp. Different methods have been applied for diagnosis of these viruses, including Real-time PCR (qPCR) assays. A duplex qPCR method allows the simultaneous detection of two viruses in the same sample, which is more cost-effective than assaying for each virus separately. Currently, an assay for the simultaneous detection of the WSSV and the PstDV1 in shrimp is unavailable. The aim of this study was to develop and standardize a duplex qPCR assay for the simultaneous detection of the WSSV and the PstDV1 in clinical samples of diseased L. vannamei. In addition, to evaluate the performance of two qPCR master mixes with regard to the clinical sensitivity of the qPCR assay, as well as, different methods for qPCR results evaluation. The duplex qPCR assay for detecting WSSV and PstDV1 in clinical samples was successfully standardized. No difference in the amplification of the standard curves was observed between the duplex and singleplex assays. Specificities and sensitivities similar to those of the singleplex assays were obtained using the optimized duplex qPCR. The analytical sensitivities of duplex qPCR were two copies of WSSV control plasmid and 20 copies of PstDV1 control plasmid. The standardized duplex qPCR confirmed the presence of viral DNA in 28 from 43 samples tested. There was no difference for WSSV detection using the two kits and the distinct methods for qPCR results evaluation. High clinical sensitivity for PstDV1 was obtained with TaqMan Universal Master Mix associated with relative threshold evaluation. Three cases of simultaneous infection by the WSSV and the PstDV1 were identified with duplex qPCR. The standardized duplex qPCR was shown to be a robust, highly sensitive, and feasible diagnostic tool for the simultaneous detection of the WSSV and the PstDV1 in whiteleg shrimp. The use of the TaqMan Universal Master Mix and the relative threshold method of data analysis in our duplex qPCR method provided optimal levels of sensitivity and specificity.

  5. Accuracy of limited four-slice CT-scan in diagnosis of chronic rhinosinusitis.

    PubMed

    Zojaji, R; Nekooei, S; Naghibi, S; Mazloum Farsi Baf, M; Jalilian, R; Masoomi, M

    2015-12-01

    Chronic rhinosinusitis (CRS) is a common chronic health condition worldwide. Standard CT-scan is the method of choice for diagnosis of CRS but its high price and considerable radiation exposure have limited its application. The main goal of this study was to evaluate the accuracy of limited four-slice coronal CT-scan in the diagnosis of CRS. This cross-sectional study was conducted on 46 patients with CRS, for one year, based on American Society of Head and Neck Surgery criteria. All patients received the preoperative standard and four-slice CT-scans, after which endoscopic sinus surgery was performed. Findings of four-slice CT-scans were compared with those of conventional CT-scan and the sensitivity and specificity of four-slice CT-scan and its agreement with conventional CT-scan was calculated. In this study, 46 patients including 32 males (69.6%) and 14 females (30.46%) with a mean age of 33 and standard deviation of 9 years, were evaluated. Sensitivity and specificity of four-slice CT-scan were 97.5% and 100%, respectively. Also, positive predictive value (PPV) and negative predictive value (NPV) of four-slice CT was 100% and 85.71%, respectively. There was a strong agreement between four-slice CT and conventional CT findings. Considering the high sensitivity and specificity of four-slice CT-scan and strong agreement with conventional CT-scan in the diagnosis of CRS and the lower radiation exposure and cost, application of this method is suggested for both diagnosis and treatment follow-up in CRS. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  6. [Sensitivity and specificity of the cerebral blood flow reactions to acupuncture in the newborn infants presenting with hypoxic ischemic encephalopathy].

    PubMed

    Filonenko, A V; Vasilenko, A M; Khan, M A

    2015-01-01

    To evaluate the effects of acupuncture integrated into the standard therapy, the condition of cerebral blood flow, and other syndromes associated with cerebral ischemia in the newborn infants. MATERIAL AND METHODS. A total of 131 pairs of puerperae and newborns with hypoxic ischemic encephalopathy were divided into four treatment groups. 34 children of the first group were given standard therapy (control), in the second group comprised of 33 mothers and children the standard treatment was supplemented by acupuncture, the third group included only 32 mothers given the acupuncture treatment alone, and the fourth group contained only 32 newborn infants treated by acupuncture. Each course of acupuncture treatment consisted of five sessions. Sensitivity and specificity of cerebral blood flow reactions were determined based on the results of the ROC-analysis and the area under the curve before and after the treatment. The treatment with the use of acupuncture greatly improved the cerebrospinal hemodynamics (p < 0.05). Other symptoms, viz. sleep disorders, vegetative reactivity and excitability were significantly reduced. The ROC analysis confirmed the effectiveness of acupuncture as a tool for the treatment of the impaired cerebral blood flow in the newborn babies. The high level of sensitivity (84.4-94.8%) associated with good specificity makes it possible to distinguish between the true positive and true negative cases. Acupuncture integrated into the treatment of "mother-baby" pairs presenting with hypoxic ischemic encephalopathy can be used to improve the initially low level of cerebral blood flow in neonates presenting with this condition.

  7. Case finding of lifestyle and mental health disorders in primary care: validation of the ‘CHAT’ tool

    PubMed Central

    Goodyear-Smith, Felicity; Coupe, Nicole M; Arroll, Bruce; Elley, C Raina; Sullivan, Sean; McGill, Anne-Thea

    2008-01-01

    Background Primary care is accessible and ideally placed for case finding of patients with lifestyle and mental health risk factors and subsequent intervention. The short self-administered Case-finding and Help Assessment Tool (CHAT) was developed for lifestyle and mental health assessment of adult patients in primary health care. This tool checks for tobacco use, alcohol and other drug misuse, problem gambling, depression, anxiety and stress, abuse, anger problems, inactivity, and eating disorders. It is well accepted by patients, GPs and nurses. Aim To assess criterion-based validity of CHAT against a composite gold standard. Design of study Conducted according to the Standards for Reporting of Diagnostic Accuracy statement for diagnostic tests. Setting Primary care practices in Auckland, New Zealand. Method One thousand consecutive adult patients completed CHAT and a composite gold standard. Sensitivities, specificities, positive and negative predictive values, and likelihood ratios were calculated. Results Response rates for each item ranged from 79.6 to 99.8%. CHAT was sensitive and specific for almost all issues screened, except exercise and eating disorders. Sensitivity ranged from 96% (95% confidence interval [CI] = 87 to 99%) for major depression to 26% (95% CI = 22 to 30%) for exercise. Specificity ranged from 97% (95% CI = 96 to 98%) for problem gambling and problem drug use to 40% (95% CI = 36 to 45%) for exercise. All had high likelihood ratios (3–30), except exercise and eating disorders. Conclusion CHAT is a valid and acceptable case-finding tool for most common lifestyle and mental health conditions. PMID:18186993

  8. Standardization of a latex agglutination test for coproantigen detection of Fasciola sp. in bovine cattle stool.

    PubMed

    Orejarena Ávila, Lina Paola; Inguilan Benavides, Erika Marcela; Padilla Sanabria, Leonardo; Recalde-Reyes, Delia Piedad; Rodríguez-Salazar, Carlos Andrés; Castaño-Osorio, Jhon Carlos

    2018-03-01

    Fasciolosis is a zoonotic parasitic disease, which affects humans and animals; diagnosed through noncommercial immunoassay tests that cannot be used on the field. Thereby, establishing the optimal conditions to develop a latex agglutination technique with IgG and IgM antibodies directed against excretion/secretion antigens of Fasciola sp. is a priority. Latex particles were sensitized with IgG and IgM antibodies directed against excretion/secretion antigens of Fasciola sp. The specificity of the antibodies was determined against antigens of different helminths and protozoa; the sensitivity and specificity of the test was evaluated against a previously standardized direct ELISA. The coupling rates of the IgG and IgM antibodies were 85.77 and 100%, respectively. The minimum detectable concentration of Fasciola sp. excretion/secretion antigens, diluted in a phosphate-buffered saline, was 1.589 mg/mL(IgG) and 0.158 mg/mL(IgM) and for the antigens incorporated in the bovine cattle stool it was 3.178 mg/mL(IgG) and 1.589 mg/mL(IgM). The test showed crossed reaction against Giardia sp., and Cryptosporidium sp. antigens. Agreement of the IgG and IgM latex test against the ELISA test was of 78.78 and 96.96%, respectively; the specificity found was of 100% for both tests and sensitivity was 78.79% (IgG) and 96.97% (IgM). This work standardized the latex agglutination technique to detect Fasciola sp. antigens in bovine cattle stool.

  9. Validation of an algorithm-based definition of treatment resistance in patients with schizophrenia.

    PubMed

    Ajnakina, Olesya; Horsdal, Henriette Thisted; Lally, John; MacCabe, James H; Murray, Robin M; Gasse, Christiane; Wimberley, Theresa

    2018-02-19

    Large-scale pharmacoepidemiological research on treatment resistance relies on accurate identification of people with treatment-resistant schizophrenia (TRS) based on data that are retrievable from administrative registers. This is usually approached by operationalising clinical treatment guidelines by using prescription and hospital admission information. We examined the accuracy of an algorithm-based definition of TRS based on clozapine prescription and/or meeting algorithm-based eligibility criteria for clozapine against a gold standard definition using case notes. We additionally validated a definition entirely based on clozapine prescription. 139 schizophrenia patients aged 18-65years were followed for a mean of 5years after first presentation to psychiatric services in South-London, UK. The diagnostic accuracy of the algorithm-based measure against the gold standard was measured with sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV). A total of 45 (32.4%) schizophrenia patients met the criteria for the gold standard definition of TRS; applying the algorithm-based definition to the same cohort led to 44 (31.7%) patients fulfilling criteria for TRS with sensitivity, specificity, PPV and NPV of 62.2%, 83.0%, 63.6% and 82.1%, respectively. The definition based on lifetime clozapine prescription had sensitivity, specificity, PPV and NPV of 40.0%, 94.7%, 78.3% and 76.7%, respectively. Although a perfect definition of TRS cannot be derived from available prescription and hospital registers, these results indicate that researchers can confidently use registries to identify individuals with TRS for research and clinical practices. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Comparison of serum specific IgE with skin prick test in the diagnosis of allergy in Malaysia.

    PubMed

    Asha'ari, Z A; Suhaimi, Y; Yusof, R A; Rushdan, I; Maraina, C H C

    2011-08-01

    We compared a newer serum specific IgE (SSIgE) test with skin prick testing (SPT) in the diagnosis of allergy in Malaysia. Ninety newly diagnosed allergic patients were enrolled for both tests. Using SPT as a clinical gold standard, the sensitivity, specificity, positive, and negative predictive values (PPV, NPV) were calculated for SSIgE for each of the common allergens tested. The highest positive results for both SPT and SSIgE were for house dust mite and cat. Compared to SPT, SSIgE showed better sensitivity but poorer specificity, low PPV and good NPV in all the allergens tested. Significant positive correlation was seen between the diameter of wheal and flare of SPT and the SSIgE results.

  11. Clinical evaluation and validation of laboratory methods for the diagnosis of Bordetella pertussis infection: Culture, polymerase chain reaction (PCR) and anti-pertussis toxin IgG serology (IgG-PT).

    PubMed

    Lee, Adria D; Cassiday, Pamela K; Pawloski, Lucia C; Tatti, Kathleen M; Martin, Monte D; Briere, Elizabeth C; Tondella, M Lucia; Martin, Stacey W

    2018-01-01

    The appropriate use of clinically accurate diagnostic tests is essential for the detection of pertussis, a poorly controlled vaccine-preventable disease. The purpose of this study was to estimate the sensitivity and specificity of different diagnostic criteria including culture, multi-target polymerase chain reaction (PCR), anti-pertussis toxin IgG (IgG-PT) serology, and the use of a clinical case definition. An additional objective was to describe the optimal timing of specimen collection for the various tests. Clinical specimens were collected from patients with cough illness at seven locations across the United States between 2007 and 2011. Nasopharyngeal and blood specimens were collected from each patient during the enrollment visit. Patients who had been coughing for ≤ 2 weeks were asked to return in 2-4 weeks for collection of a second, convalescent blood specimen. Sensitivity and specificity of each diagnostic test were estimated using three methods-pertussis culture as the "gold standard," composite reference standard analysis (CRS), and latent class analysis (LCA). Overall, 868 patients were enrolled and 13.6% were B. pertussis positive by at least one diagnostic test. In a sample of 545 participants with non-missing data on all four diagnostic criteria, culture was 64.0% sensitive, PCR was 90.6% sensitive, and both were 100% specific by LCA. CRS and LCA methods increased the sensitivity estimates for convalescent serology and the clinical case definition over the culture-based estimates. Culture and PCR were most sensitive when performed during the first two weeks of cough; serology was optimally sensitive after the second week of cough. Timing of specimen collection in relation to onset of illness should be considered when ordering diagnostic tests for pertussis. Consideration should be given to including IgG-PT serology as a confirmatory test in the Council of State and Territorial Epidemiologists (CSTE) case definition for pertussis.

  12. [The role of endotracheal aspirate culture in the diagnosis of ventilator-associated pneumonia: a meta analysis].

    PubMed

    Wang, Fei; He, Bei

    2013-01-01

    To investigate the role of endotracheal aspirate (EA) culture in the diagnosis and antibiotic management in ventilator-associated pneumonia (VAP). We searched CNKI, Wanfang, PUBMED and EMBASE databases published from January 1990 to December 2011, to find relevant literatures on VAP microbiological diagnostic techniques including EA and bronchoalveolar lavage (BALF). The following key words were used: ventilator associated pneumonia, diagnosis and adult. Meta-analysis was performed and the sensitivity and specificity of EA on VAP diagnosis were calculated. Our literature search identified 1665 potential articles, 8 of which fulfilled our selection criteria including 561 patients with paired cultures. Using BALF quantitative culture as reference standard, the sensitivity and specificity of EA were 72% and 71%. When considering quantitative culture of EA only, the sensitivity and specificity improved to 90% and 65%, while the positive and the negative predictive values were 68% and 89% respectively. However, the sensitivity and specificity of semi-quantitative culture of EA were only 50% and 80%, with a positive predictive value of 77% and a negative predictive value of 58% respectively. EA culture had relatively poor sensitivity and specificity, although quantitative culture of EA only could improve the sensitivity. Initiating therapy on the basis of EA quantitative culture may still result in excessive antibiotic usage. Our data suggested that EA could provide some information for clinical decision but could not replace the role of BALF quantitative culture in VAP diagnosis.

  13. The role of oncogenic human papillomavirus determination for diagnosis of high-grade anal intraepithelial neoplasia in HIV-infected MSM.

    PubMed

    Burgos, Joaquin; Hernández-Losa, Javier; Landolfi, Stefania; Guelar, Ana; Dinares, MªCarmen; Villar, Judith; Navarro, Jordi; Ribera, Esteve; Falcó, Vicenç; Curran, Adria

    2017-10-23

    To assess the oncogenic human papillomavirus (HPV) determination and the cotesting HPV and anal cytology value to detect high-grade anal intraepithelial neoplasia (HGAIN) in a cohort of HIV-MSM. Prospective study of HIV-infected MSM who underwent screening for anal dysplasia. Screening program includes anal cytology, HPV testing, and high-resolution anoscopy (HRA) at each visit. Histological samples were obtained if suspicious lesions were revealed by HRA. Sensitivity and specificity of the different tests were calculated by using histological results of HRA-guided biopsy as the reference test for HGAIN diagnosis. From May 2009 to August 2016, 692 HIV-infected MSM underwent 1827 anal cytologies, 1841 HRA examinations, and 1607 HPV testing. At first screening visit, anal cytology results were abnormal in 418 (60.4%) of 692 patients, and oncogenic HPV genotypes were found in 482 (79.5%) of 606 patients. Anal cytology showed a sensitivity of 89.2% [95% confidence interval (CI); 80.7-94.2] and a specificity of 44.2% (95% CI; 40.2-48.2) to detect HGAIN. Oncogenic HPV testing had 90.4% sensitivity (95% CI; 82-86.8) and 24.4% specificity (95% CI; 20.8-28.3). Cotesting showed a 97.4% sensitivity (95% CI; 91-99.3) and 14% specificity (95% CI; 11.2-17.3). In patients with atypical squamous cells of uncertain significance on cytology, oncogenic HPV testing had 91.3% sensitivity and 28.3% specificity to detect HGAIN. Abnormal cytology and oncogenic HPV determination showed similar sensitivity for detecting HGAIN. The two tests used together improved the sensitivity but with lowered specificity. In our opinion, HPV testing does not improve HGAIN detection and should not replace anal cytology as a standard screening test for HIV-infected MSM.

  14. Birth attendants as perinatal verbal autopsy respondents in low- and middle-income countries: a viable alternative?

    PubMed Central

    Garces, A; Jehan, I; Ditekemena, J; Phiri, M; Thorsten, V; Mazariegos, M; Chomba, E; Pasha, O; Tshefu, A; Wallace, D; McClure, EM; Goldenberg, RL; Carlo, WA; Wright, LL; Bose, C

    2012-01-01

    Abstract Objective To assess the feasibility of using birth attendants instead of bereaved mothers as perinatal verbal autopsy respondents. Methods Verbal autopsy interviews for early neonatal deaths and stillbirths were conducted separately among mothers (reference standard) and birth attendants in 38 communities in four developing countries. Concordance between maternal and attendant responses was calculated for all questions, for categories of questions and for individual questions. The sensitivity and specificity of individual questions with the birth attendant as respondent were assessed. Findings For early neonatal deaths, concordance across all questions was 94%. Concordance was at least 95% for more than half the questions on maternal medical history, birth attendance and neonate characteristics. Concordance on any given question was never less than 80%. Sensitivity and specificity varied across individual questions, more than 80% of which had a sensitivity of at least 80% and a specificity of at least 90%. For stillbirths, concordance across all questions was 93%. Concordance was 95% or greater more than half the time for questions on birth attendance, site of delivery and stillborn characteristics. Sensitivity and specificity varied across individual questions. Over 60% of the questions had a sensitivity of at least 80% and over 80% of them had a specificity of at least 90%. Overall, the causes of death established through verbal autopsy were similar, regardless of respondent. Conclusion Birth attendants can substitute for bereaved mothers as verbal autopsy respondents. The questions in existing harmonized verbal autopsy questionnaires need further refinement, as their sensitivity and specificity differ widely. PMID:22461715

  15. Accuracy of dementia diagnosis: a direct comparison between radiologists and a computerized method.

    PubMed

    Klöppel, Stefan; Stonnington, Cynthia M; Barnes, Josephine; Chen, Frederick; Chu, Carlton; Good, Catriona D; Mader, Irina; Mitchell, L Anne; Patel, Ameet C; Roberts, Catherine C; Fox, Nick C; Jack, Clifford R; Ashburner, John; Frackowiak, Richard S J

    2008-11-01

    There has been recent interest in the application of machine learning techniques to neuroimaging-based diagnosis. These methods promise fully automated, standard PC-based clinical decisions, unbiased by variable radiological expertise. We recently used support vector machines (SVMs) to separate sporadic Alzheimer's disease from normal ageing and from fronto-temporal lobar degeneration (FTLD). In this study, we compare the results to those obtained by radiologists. A binary diagnostic classification was made by six radiologists with different levels of experience on the same scans and information that had been previously analysed with SVM. SVMs correctly classified 95% (sensitivity/specificity: 95/95) of sporadic Alzheimer's disease and controls into their respective groups. Radiologists correctly classified 65-95% (median 89%; sensitivity/specificity: 88/90) of scans. SVM correctly classified another set of sporadic Alzheimer's disease in 93% (sensitivity/specificity: 100/86) of cases, whereas radiologists ranged between 80% and 90% (median 83%; sensitivity/specificity: 80/85). SVMs were better at separating patients with sporadic Alzheimer's disease from those with FTLD (SVM 89%; sensitivity/specificity: 83/95; compared to radiological range from 63% to 83%; median 71%; sensitivity/specificity: 64/76). Radiologists were always accurate when they reported a high degree of diagnostic confidence. The results show that well-trained neuroradiologists classify typical Alzheimer's disease-associated scans comparable to SVMs. However, SVMs require no expert knowledge and trained SVMs can readily be exchanged between centres for use in diagnostic classification. These results are encouraging and indicate a role for computerized diagnostic methods in clinical practice.

  16. Accuracy of dementia diagnosis—a direct comparison between radiologists and a computerized method

    PubMed Central

    Stonnington, Cynthia M.; Barnes, Josephine; Chen, Frederick; Chu, Carlton; Good, Catriona D.; Mader, Irina; Mitchell, L. Anne; Patel, Ameet C.; Roberts, Catherine C.; Fox, Nick C.; Jack, Clifford R.; Ashburner, John; Frackowiak, Richard S. J.

    2008-01-01

    There has been recent interest in the application of machine learning techniques to neuroimaging-based diagnosis. These methods promise fully automated, standard PC-based clinical decisions, unbiased by variable radiological expertise. We recently used support vector machines (SVMs) to separate sporadic Alzheimer's disease from normal ageing and from fronto-temporal lobar degeneration (FTLD). In this study, we compare the results to those obtained by radiologists. A binary diagnostic classification was made by six radiologists with different levels of experience on the same scans and information that had been previously analysed with SVM. SVMs correctly classified 95% (sensitivity/specificity: 95/95) of sporadic Alzheimer's disease and controls into their respective groups. Radiologists correctly classified 65–95% (median 89%; sensitivity/specificity: 88/90) of scans. SVM correctly classified another set of sporadic Alzheimer's disease in 93% (sensitivity/specificity: 100/86) of cases, whereas radiologists ranged between 80% and 90% (median 83%; sensitivity/specificity: 80/85). SVMs were better at separating patients with sporadic Alzheimer's disease from those with FTLD (SVM 89%; sensitivity/specificity: 83/95; compared to radiological range from 63% to 83%; median 71%; sensitivity/specificity: 64/76). Radiologists were always accurate when they reported a high degree of diagnostic confidence. The results show that well-trained neuroradiologists classify typical Alzheimer's disease-associated scans comparable to SVMs. However, SVMs require no expert knowledge and trained SVMs can readily be exchanged between centres for use in diagnostic classification. These results are encouraging and indicate a role for computerized diagnostic methods in clinical practice. PMID:18835868

  17. Investigation of the feasibility of non-invasive optical sensors for the quantitative assessment of dehydration.

    PubMed

    Visser, Cobus; Kieser, Eduard; Dellimore, Kiran; van den Heever, Dawie; Smith, Johan

    2017-10-01

    This study explores the feasibility of prospectively assessing infant dehydration using four non-invasive, optical sensors based on the quantitative and objective measurement of various clinical markers of dehydration. The sensors were investigated to objectively and unobtrusively assess the hydration state of an infant based on the quantification of capillary refill time (CRT), skin recoil time (SRT), skin temperature profile (STP) and skin tissue hydration by means of infrared spectrometry (ISP). To evaluate the performance of the sensors a clinical study was conducted on a cohort of 10 infants (aged 6-36 months) with acute gastroenteritis. High sensitivity and specificity were exhibited by the sensors, in particular the STP and SRT sensors, when combined into a fusion regression model (sensitivity: 0.90, specificity: 0.78). The SRT and STP sensors and the fusion model all outperformed the commonly used "gold standard" clinical dehydration scales including the Gorelick scale (sensitivity: 0.56, specificity: 0.56), CDS scale (sensitivity: 1.0, specificity: 0.2) and WHO scale (sensitivity: 0.13, specificity: 0.79). These results suggest that objective and quantitative assessment of infant dehydration may be possible using the sensors investigated. However, further evaluation of the sensors on a larger sample population is needed before deploying them in a clinical setting. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  18. Optical Coherence Tomography Angiography versus Dye Angiography in Age-Related Macular Degeneration: Sensitivity and Specificity Analysis.

    PubMed

    Nikolopoulou, Eleni; Lorusso, Massimo; Micelli Ferrari, Luisa; Cicinelli, Maria Vittoria; Bandello, Francesco; Querques, Giuseppe; Micelli Ferrari, Tommaso

    2018-01-01

    Optical coherence tomography angiography (OCTA) could be a valid tool to detect choroidal neovascularization (CNV) in neovascular age-related macular degeneration (nAMD), allowing the analysis of the type, the morphology, and the extension of CNV in most of the cases. To determine the sensitivity and specificity of OCTA in detecting CNV secondary to nAMD, compared to fluorescein angiography (FA) and indocyanine green angiography (ICGA). Prospective observational study. Patients with suspected nAMD were recruited between May and December 2016. Patients underwent FA, ICGA, spectral domain OCT, and OCTA (AngioVue, Optovue, Inc.). Sensitivity and specificity of FA, with or without ICGA, were assessed and compared with OCTA. Seventy eyes of 70 consecutive patients were included: 32 eyes (45.7%) with type I CNV, 8 eyes (11.4%) with type II CNV, 4 eyes (5.7%) with type III CNV, 6 eyes (8.6%) with mixed type I and type II CNV, and 20 eyes (28.6%) with no CNV. Sensitivity of OCTA was 88% and specificity was 90%. Concordance between FA/ICGA and OCTA was very good (0,91; range 0,81-1,00). OCTA showed high sensitivity and specificity for detection of CNV. Concordance between OCTA and gold-standard dye-based techniques was excellent. OCTA may represent a first-line noninvasive method for the diagnosis of nAMD.

  19. Diagnostic test accuracy of nutritional tools used to identify undernutrition in patients with colorectal cancer: a systematic review.

    PubMed

    Håkonsen, Sasja Jul; Pedersen, Preben Ulrich; Bath-Hextall, Fiona; Kirkpatrick, Pamela

    2015-05-15

    Effective nutritional screening, nutritional care planning and nutritional support are essential in all settings, and there is no doubt that a health service seeking to increase safety and clinical effectiveness must take nutritional care seriously. Screening and early detection of malnutrition is crucial in identifying patients at nutritional risk. There is a high prevalence of malnutrition in hospitalized patients undergoing treatment for colorectal cancer. To synthesize the best available evidence regarding the diagnostic test accuracy of nutritional tools (sensitivity and specificity) used to identify malnutrition (specifically undernutrition) in patients with colorectal cancer (such as the Malnutrition Screening Tool and Nutritional Risk Index) compared to reference tests (such as the Subjective Global Assessment or Patient Generated Subjective Global Assessment). Patients with colorectal cancer requiring either (or all) surgery, chemotherapy and/or radiotherapy in secondary care. Focus of the review: The diagnostic test accuracy of validated assessment tools/instruments (such as the Malnutrition Screening Tool and Nutritional Risk Index) in the diagnosis of malnutrition (specifically under-nutrition) in patients with colorectal cancer, relative to reference tests (Subjective Global Assessment or Patient Generated Subjective Global Assessment). Types of studies: Diagnostic test accuracy studies regardless of study design. Studies published in English, German, Danish, Swedish and Norwegian were considered for inclusion in this review. Databases were searched from their inception to April 2014. Methodological quality was determined using the Quality Assessment of Diagnostic Accuracy Studies checklist. Data was collected using the data extraction form: the Standards for Reporting Studies of Diagnostic Accuracy checklist for the reporting of studies of diagnostic accuracy. The accuracy of diagnostic tests is presented in terms of sensitivity, specificity, positive and negative predictive values. In addition, the positive likelihood ratio (sensitivity/ [1 - specificity]) and negative likelihood ratio (1 - sensitivity)/ specificity), were also calculated and presented in this review to provide information about the likelihood that a given test result would be expected when the target condition is present compared with the likelihood that the same result would be expected when the condition is absent. Not all trials reported true positive, true negative, false positive and false negative rates, therefore these rates were calculated based on the data in the published papers. A two-by-two truth table was reconstructed for each study, and sensitivity, specificity, positive predictive value, negative predictive value positive likelihood ratio and negative likelihood ratio were calculated for each study. A summary receiver operator characteristics curve was constructed to determine the relationship between sensitivity and specificity, and the area under the summary receiver operator characteristics curve which measured the usefulness of a test was calculated. Meta-analysis was not considered appropriate, therefore data was synthesized in a narrative summary. 1. One study evaluated the Malnutrition Screening Tool against the reference standard Patient-Generated Subjective Global Assessment. The sensitivity was 56% and the specificity 84%. The positive likelihood ratio was 3.100, negative likelihood ratio was 0.59, the diagnostic odds ratio (CI 95%) was 5.20 (1.09-24.90) and the Area Under the Curve (AUC) represents only a poor to fair diagnostic test accuracy. A total of two studies evaluated the diagnostic accuracy of Malnutrition Universal Screening Tool (MUST) (index test) compared to both Subjective Global Assessment (SGA) (reference standard) and PG-SGA (reference standard) in patients with colorectal cancer. In MUST vs SGA the sensitivity of the tool was 96%, specificity was 75%, LR+ 3.826, LR- 0.058, diagnostic OR (CI 95%) 66.00 (6.61-659.24) and AUC represented excellent diagnostic accuracy. In MUST vs PG-SGA the sensitivity of the tool was 72%, specificity 48.9%, LR+ 1.382, LR- 0.579, diagnostic OR (CI 95%) 2.39 (0.87-6.58) and AUC indicated that the tool failed as a diagnostic test to identify patients with colorectal cancer at nutritional risk,. The Nutrition Risk Index (NRI) was compared to SGA representing a sensitivity of 95.2%, specificity of 62.5%, LR+ 2.521, LR- 0.087, diagnostic OR (CI 95%) 28.89 (6.93-120.40) and AUC represented good diagnostic accuracy. In regard to NRI vs PG-SGA the sensitivity of the tool was 68%, specificity 64%, LR+ 1.947, LR- 0.487, diagnostic OR (CI 95%) 4.00 (1.23-13.01) and AUC indicated poor diagnostic test accuracy. There are no single, specific tools used to screen or assess the nutritional status of colorectal cancer patients. All tools showed varied diagnostic accuracies when compared to the reference standards SGA and PG-SGA. Hence clinical judgment combined with perhaps the SGA or PG-SGA should play a major role. The PG-SGA offers several advantages over the SGA tool: 1) the patient completes the medical history component, thereby decreasing the amount of time involved; 2) it contains more nutrition impact symptoms, which are important to the patient with cancer; and 3) it has a scoring system that allows patients to be triaged for nutritional intervention. Therefore, the PG-SGA could be used as a nutrition assessment tool as it allows quick identification and prioritization of colorectal cancer patients with malnutrition in combination with other parameters. This systematic review highlights the need for the following: Further studies needs to investigate the diagnostic accuracy of already existing nutritional screening tools in the context of colorectal cancer patients. If new screenings tools are developed, they should be developed and validated in the specific clinical context within the same patient population (colorectal cancer patients). The Joanna Briggs Institute.

  20. Detecting High Hyperopia: The Plus Lens Test and the Spot Vision Screener.

    PubMed

    Feldman, Samuel; Peterseim, Mae Millicent W; Trivedi, Rupal H; Edward Wilson, M; Cheeseman, Edward W; Papa, Carrie E

    2017-05-01

    To evaluate the usefulness of the Plus Lens (Goodlite Company, Elgin, IL) test and the Spot Vision Screener (Welch Allyn, Skaneateles Falls, NY) in detecting high hyperopia in a pediatric population. Between June and August 2015, patients were screened with the Spot Vision Screener and the Plus Lens test prior to a scheduled pediatric ophthalmology visit. The following data were analyzed: demographic data, Plus Lens result, Spot Vision Screener result, cycloplegic refraction, and examination findings. Sensitivity/specificity and positive/negative predictive values were calculated for the Plus Lens test and Spot Vision Screener in detecting hyperopia as determined by the "gold-standard" cycloplegic refraction. A total of 109 children (average age: 82 months) were included. Compared to the ophthalmologist's cycloplegic refraction, the Spot Vision Screener sensitivity for +3.50 diopters (D) hyperopia was 31.25% and the specificity was 100%. The Plus Lens sensitivity for +3.50 D hyperopia was 43.75% and the specificity was 89.25%. Spot Vision Screener sensitivity increased with higher degrees of hyperopia. In this preliminary study, the Plus Lens test and the Spot Vision Screener demonstrated moderate sensitivity with good specificity in detecting high hyperopia. [J Pediatr Ophthalmol Strabismus. 2017;54(3):163-167.]. Copyright 2017, SLACK Incorporated.

  1. Performance of Ultrasound in the Diagnosis of Gout in a Multicenter Study: Comparison With Monosodium Urate Monohydrate Crystal Analysis as the Gold Standard.

    PubMed

    Ogdie, Alexis; Taylor, William J; Neogi, Tuhina; Fransen, Jaap; Jansen, Tim L; Schumacher, H Ralph; Louthrenoo, Worawit; Vazquez-Mellado, Janitzia; Eliseev, Maxim; McCarthy, Geraldine; Stamp, Lisa K; Perez-Ruiz, Fernando; Sivera, Francisca; Ea, Hang-Korng; Gerritsen, Martijn; Cagnotto, Giovanni; Cavagna, Lorenzo; Lin, Chingtsai; Chou, Yin-Yi; Tausche, Anne-Kathrin; Lima Gomes Ochtrop, Manuella; Janssen, Matthijs; Chen, Jiunn-Horng; Slot, Ole; Lazovskis, Juris; White, Douglas; Cimmino, Marco A; Uhlig, Till; Dalbeth, Nicola

    2017-02-01

    To examine the performance of ultrasound (US) for the diagnosis of gout using the presence of monosodium urate monohydrate (MSU) crystals as the gold standard. We analyzed data from the Study for Updated Gout Classification Criteria (SUGAR), a large, multicenter observational cross-sectional study of consecutive subjects with at least 1 swollen joint who conceivably may have gout. All subjects underwent arthrocentesis; cases were subjects with confirmed MSU crystals. Rheumatologists or radiologists who were blinded with regard to the results of the MSU crystal analysis performed US on 1 or more clinically affected joints. US findings of interest were double contour sign, tophus, and snowstorm appearance. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated. Multivariable logistic regression models were used to examine factors associated with positive US results among subjects with gout. US was performed in 824 subjects (416 cases and 408 controls). The sensitivity, specificity, PPV, and NPV for the presence of any 1 of the features were 76.9%, 84.3%, 83.3%, and 78.2%, respectively. Sensitivity was higher among subjects with a disease duration of ≥2 years and among subjects with subcutaneous nodules on examination (suspected tophus). Associations with a positive US finding included suspected clinical tophus (odds ratio [OR] 4.77 [95% confidence interval (95% CI) 2.23-10.21]), any abnormality on plain radiography (OR 4.68 [95% CI 2.68-8.17]), and serum urate level (OR 1.31 [95% CI 1.06-1.62]). US features of MSU crystal deposition had high specificity and high PPV but more limited sensitivity for early gout. The specificity remained high in subjects with early disease and without clinical signs of tophi. © 2016, American College of Rheumatology.

  2. Establishment and Evaluation of a One-Step Microplate Chemiluminescence Immunoassay to Detect IgG Antibody Against Treponema Pallidum.

    PubMed

    Liu, Lijuan; Xie, Yuling; Dai, Zhenxian; Zhuo, Chuanshang; Wu, Yushui

    2015-11-01

    The serological detection of specific antibodies against Treponema pallidum is of particular importance in the diagnosis of syphilis. The chemiluminescence immunoassay (CLIA) has been widely used for clinical diagnosis because they remit no radical waste products, cause no enzyme precipitation, and exhibit an excellent sensitivity. A one-step CLIA was established to detect T. pallidum IgG antibody based on microplate coated with a mixture of recombinant T. pallidum antigens TpN15, TpN17, and TpN47. The Chinese national reference substances standard panel for T. pallidum diagnosis was applied to test the accuracy, stability, interference, and cross-reactivity of the established CLIA. The validation of efficacy for clinical application was performed by comparing the established method with the marketed T. pallidum particle agglutination (TPPA) kit and the Abbott ARCHITEC Auto System. The established method met the requirement of the Chinese national reference substances standard for T. pallidum diagnosis. When compared with TPPA (n = 1,052), the specificity, sensitivity, and overall concordance were 99.7%, 99.0%, and 98.8% respectively, showing a great agreement with a kappa value of 0.81. When compared with the Abbott ARCHITEC Auto System (n = 352), the results showed that the specificity, sensitivity, and overall concordance were 98.6.0%, 96.6% and 98.6% respectively, and a high-degree agreement was observed (kappa value = 0.95). The established rapid, specific, sensitive, and stable microplate CLIA method to detect IgG antibody against T pallidum will provide an efficient alternative to the treponemal tests and wide application in clinical laboratory. © 2014 Wiley Periodicals, Inc.

  3. Diagnostic performance of short portable mental status questionnaire for screening dementia among patients attending cognitive assessment clinics in Singapore.

    PubMed

    Malhotra, Chetna; Chan, Angelique; Matchar, David; Seow, Dennis; Chuo, Adeline; Do, Young Kyung

    2013-07-01

    The Short Portable Mental Status Questionnaire (SPMSQ) is a brief cognitive screening instrument, which is easy to use by a healthcare worker with little training. However, the validity of this instrument has not been established in Singapore. Thus, the primary aim of this study was to determine the diagnostic performance of SPMSQ for screening dementia among patients attending outpatient cognitive assessment clinics and to assess whether the appropriate cut-off score varies by patient's age and education. A secondary aim of the study was to map the SPMSQ scores with Mini-Mental State Examination (MMSE) scores. SPMSQ and MMSE were administered by a trained interviewer to 127 patients visiting outpatient cognitive assessment clinics at the Singapore General Hospital, Changi General Hospital and Tan Tock Seng Hospital. The geriatricians at these clinics then diagnosed these patients with dementia or no dementia (reference standard). Sensitivity and specificity of SPMSQ with different cut-off points (number of errors) were calculated and compared to the reference standard using the Receiver Operator Characteristic (ROC) analysis. Correlation coefficient was also calculated between MMSE and SPMSQ scores. Based on the ROC analysis and a balance of sensitivity and specificity, the appropriate cut-off for SPMSQ was found to be 5 or more errors (sensitivity 78%, specificity 75%). The cut-off varied by education, but not by patient's age. There was a high correlation between SPMSQ and MMSE scores (r = 0.814, P <0.0001). Despite the advantage of being a brief screening instrument for dementia, the use of SPMSQ is limited by its low sensitivity and specificity, especially among patients with less than 6 years of education.

  4. A sensitive one-step TaqMan amplification approach for detection of rubella virus clade I and II genotypes in clinical samples.

    PubMed

    Claus, C; Bergs, S; Emmrich, N C; Hübschen, J M; Mankertz, A; Liebert, U G

    2017-02-01

    Although teratogenic rubella virus (RV) causes a vaccine-preventable disease, it is still endemic in several countries worldwide. Thus, there is a constant risk of RV importation into non-endemic areas. RV monitoring, especially during measles and Zika virus outbreaks, requires reliable diagnostic tools. For this study, a TaqMan-based one-step reverse transcription-quantitative PCR (RT-qPCR) assay, with the p90 gene as a novel and so far unexplored target for detection of clade I and II genotypes, was developed and evaluated. Automated nucleic acid extraction was carried out. Performance characteristics of the TaqMan RT-qPCR assay were determined for a RV plasmid standard and RNA extracted from virus-infected cell culture supernatants representing clade I and II genotypes. Diagnostic specificity and sensitivity were validated against other RNA and DNA viruses, relevant for RV diagnostic approaches and for RV-positive clinical samples, respectively. The assay is specific and highly sensitive with a limit of detection as low as five to one copies per reaction or 200 infectious virus particles per ml. The coefficients of variation (CV) were specified as intra- (within one run) and inter- (between different runs) assay variation, and calculated based on the standard deviations for the obtained Ct values of the respective samples. Intra- and inter-assay CV values were low, with a maximum of 3.4% and 2.4%, respectively. The assay was shown to be suitable and specific for the analysis of clinical samples. With p90 as a novel target, the highly sensitive and specific TaqMan assay outlined in this study is suitable for RV diagnosis worldwide.

  5. Performance of Ultrasound in the Diagnosis of Gout in a Multi-Center Study: Comparison with Monosodium Urate Crystal Analysis as the Gold Standard

    PubMed Central

    Ogdie, Alexis; Taylor, William J; Neogi, Tuhina; Fransen, Jaap; Jansen, Tim L; Schumacher, H. Ralph; Louthrenoo, Worawit; Vazquez-Mellado, Janitzia; Eliseev, Maxim; McCarthy, Geraldine; Stamp, Lisa K.; Perez-Ruiz, Fernando; Sivera, Francisca; Ea, Hang-Korng; Gerritsen, Martijn; Cagnotto, Giovanni; Cavagna, Lorenzo; Lin, Chingtsai; Chou, Yin-Yi; Tausche, Anne-Kathrin; Ochtrop, Manuella Lima Gomes; Janssen, Matthijs; Chen, Jiunn-Horng; Slot, Ole; Lazovskis, Juris; White, Douglas; Cimmino, Marco A.; Uhlig, Till; Dalbeth, Nicola

    2017-01-01

    Objectives To examine the performance of ultrasound for the diagnosis of gout using presence of monosodium urate (MSU) crystals as the gold standard. Methods We analyzed data from the Study for Updated Gout Classification Criteria (SUGAR), a large, multi-center observational cross-sectional study of consecutive subjects with at least one swollen joint who conceivably may have gout. All subjects underwent arthrocentesis; cases were subjects with MSU crystal confirmation. Rheumatologists or radiologists, blinded to the results of the MSU crystal analysis, performed ultrasound on one or more clinically affected joints. Ultrasound findings of interest were: double contour sign (DCS), tophus, and ‘snowstorm’ appearance. Sensitivity, specificity, positive and negative predictive values (PPV and NPV) were calculated. Multivariable logistic regression models were used to examine factors associated with positive ultrasound results among subjects with gout. Results Ultrasound was performed in 824 subjects (416 cases and 408 controls). The sensitivity, specificity, PPV and NPV for the presence of any one of the features were 76.9%, 84.3%, 83.3% and 78.1% respectively. Sensitivity was higher among subjects with disease ≥2 years duration and among subjects with subcutaneous nodules on exam (suspected tophus). Associations with a positive ultrasound finding included suspected clinical tophus (odds ratio 4.77; 95% CI 2.23–10.21), any abnormal plain film radiograph (4.68; 2.68–8.17) and serum urate (1.31; 1.06–1.62). Conclusions Ultrasound features of MSU crystal deposition had high specificity and high positive predictive value but more limited sensitivity for early gout. The specificity remained high in subjects with early disease and without clinical signs of tophi. PMID:27748084

  6. Initial accuracy assessment of the modified S-LANSS for the detection of neuropathic orofacial pain conditions.

    PubMed

    Herrero Babiloni, Alberto; Nixdorf, Donald R; Law, Alan S; Moana-Filho, Estephan J; Shueb, Sarah S; Nguyen, Ruby H; Durham, Justin

    2017-01-01

    To evaluate the accuracy of a questionnaire modified for the identification of intraoral pain with neuropathic characteristics in a clinical orofacial pain sample population. 136 participants with at least one of four orofacial pain diagnoses (temporomandibular disorders [TMD, n = 41], acute dental pain [ADP, n = 41], trigeminal neuralgia [TN, n = 19], persistent dentoalveolar pain disorder [PDAP, n = 14]) and a group of pain-free controls (n = 21) completed the modified S-LANSS, a previously adapted version of the original questionnaire devised to detected patients suffering from intraoral pain with neuropathic characteristics. Psychometric properties (sensitivity, specificity, positive predictive value [PPV], negative predictive value [NPV]) were calculated in two analyses with two different thresholds: (1) Detection of pain with neuropathic characteristics: PDAP + TN were considered positive, and TMD + ADP + controls were considered negative per gold standard (expert opinion). (2) Detection of PDAP: PDAP was considered positive and TMD + ADP were considered negative per gold standard. For both analyses, target values for adequate sensitivity and specificity were defined as ≥ 80%. For detection of orofacial pain with neuropathic characteristics (PDAP + TN), the modified S-LANSS presented with the most optimistic threshold sensitivity of 52% (95% confidence interval [CI], 34-69), specificity of 70% (95% CI, 60-79), PPV of 35% (95% CI, 22-51), and NPV of 82% (95% CI, 72-89). For detection of PDAP only, with the most optimistic threshold sensitivity was 64% (95% CI, 35-87), specificity 63% (95% CI, 52-74), PPV 23% (95% CI, 11-39) and NPV 91% (95% CI, 81-97). Based on a priori defined criteria, the modified S-LANSS did not show adequate accuracy to detect intraoral pain with neuropathic characteristics in a clinical orofacial pain sample.

  7. Diagnostic accuracy of direct ophthalmoscopy for detection of diabetic retinopathy using fundus photographs as a reference standard.

    PubMed

    Ahsan, Shahid; Basit, Abdul; Ahmed, Kazi Rumana; Ali, Liaquat; Shaheen, Fariha; Ulhaque, Muhammad Saif; Fawwad, Asher

    2014-01-01

    To determine the diagnostic accuracy of direct ophthalmoscopy for the presence and severity of diabetic retinopathy (DR) using fundus photographs as a reference standard. Patients with type 2 diabetes attending the outpatient department (OPD) of a tertiary care diabetes center, from October 2009 to March 2010 were recruited in the study after obtaining signed informed consent. Patients with type 1 diabetes and gestational diabetes or having eye problems were excluded. After checking visual acuity, direct ophthalmoscopy of each eye was done by diabetologist, followed by photography of two fields of retina by fundus camera. DR was graded by a retinal specialist, according to International Diabetic Retinopathy Disease Severity Scale. According to severity, patients with DR were grouped into non-sight threatening diabetic retinopathy (NSTDR) and sight threatening diabetic retinopathy (STDR). Sensitivity and specificity of direct ophthalmoscopy for detection of any retinopathy, NSTDR and STDR was calculated. A total of 728 eyes were examined by direct ophthalmoscopy as well as fundus photography. Sensitivity (95% CI) of direct ophthalmoscopy for any retinopathy, NSTDR and STDR was found to be 55.67% (50.58-60.78), 37.63% (32.67-42.59) and 68.25% (63.48-73.02) respectively. Whereas, specificity of direct ophthalmoscopy was found to be 76.78% (72.45-81.11), 71.27% (CI: 66.63-75.91) and 90.0% (86.93-93.07) for any retinopathy, NSTDR and STDR respectively. The sensitivity and specificity of direct ophthalmoscopy performed by the diabetologist for the presence and severity of DR was lower compared to the recommended level of sensitivity and specificity of a screening test of DR. Copyright © 2014 Diabetes India. Published by Elsevier Ltd. All rights reserved.

  8. Near Infrared Imaging as a Diagnostic Tool for Detecting Enamel Demineralization: An in vivo Study

    NASA Astrophysics Data System (ADS)

    Lucas, Seth Adam

    Background and Objectives: For decades there has been an effort to develop alternative optical methods of imaging dental decay utilizing non-ionizing radiation methods. The purpose of this in-vivo study was to demonstrate whether NIR can be used as a diagnostic tool to evaluate dental caries and to compare the sensitivity and specificity of this method with that of conventional methods, including bitewing x-rays and visual inspection. Materials and Methods: 31 test subjects (n=31) from the UCSF orthodontic clinic undergoing orthodontic treatment with planned premolar extractions were recruited. Calibrated examiners performed caries detection examinations using conventional methods: bitewing radiographs and visual inspection. These findings were compared with the results from NIR examinations: transillumination and reflectance. To confirm the results found in the two different detection methods, a gold standard was used. After teeth were extracted, polarized light microscopy and transverse microradiography were performed. Results: A total of 87 premolars were used in the study. NIR identified the occlusal lesions with a sensitivity of 71% and a specificity of 77%, whereas, the visual examination had a sensitivity of only 40% and a specifity of 39%. For interproximal lesions halfway to DEJ, specificity remained constant, but sensitivity improved to 100% for NIR and 75% for x-rays. Conclusions: The results of this preliminary study demonstrate that NIR is just as effective at detecting enamel interproximal lesions as standard dental x-rays. NIR was more effective at detecting occlusal lesions than visual examination alone. NIR shows promise as an alternative diagnostic tool to the conventional methods of x-rays and visual examination and provides a non-ionizing radiation technique.

  9. A systematic review of the diagnostic accuracy of provocative tests of the neck for diagnosing cervical radiculopathy

    PubMed Central

    Pool, Jan J. M.; van Tulder, Maurits W.; Riphagen, Ingrid I.; de Vet, Henrica C. W.

    2006-01-01

    Clinical provocative tests of the neck, which position the neck and arm inorder to aggravate or relieve arm symptoms, are commonly used in clinical practice in patients with a suspected cervical radiculopathy. Their diagnostic accuracy, however, has never been examined in a systematic review. A comprehensive search was conducted in order to identify all possible studies fulfilling the inclusion criteria. A study was included if: (1) any provocative test of the neck for diagnosing cervical radiculopathy was identified; (2) any reference standard was used; (3) sensitivity and specificity were reported or could be (re-)calculated; and, (4) the publication was a full report. Two reviewers independently selected studies, and assessed methodological quality. Only six studies met the inclusion criteria, which evaluated five provocative tests. In general, Spurling’s test demonstrated low to moderate sensitivity and high specificity, as did traction/neck distraction, and Valsalva’s maneuver. The upper limb tension test (ULTT) demonstrated high sensitivity and low specificity, while the shoulder abduction test demonstrated low to moderate sensitivity and moderate to high specificity. Common methodological flaws included lack of an optimal reference standard, disease progression bias, spectrum bias, and review bias. Limitations include few primary studies, substantial heterogeneity, and numerous methodological flaws among the studies; therefore, a meta-analysis was not conducted. This review suggests that, when consistent with the history and other physical findings, a positive Spurling’s, traction/neck distraction, and Valsalva’s might be indicative of a cervical radiculopathy, while a negative ULTT might be used to rule it out. However, the lack of evidence precludes any firm conclusions regarding their diagnostic value, especially when used in primary care. More high quality studies are necessary in order to resolve this issue. PMID:17013656

  10. Lung Ultrasound-Implemented Diagnosis of Acute Decompensated Heart Failure in the ED: A SIMEU Multicenter Study.

    PubMed

    Pivetta, Emanuele; Goffi, Alberto; Lupia, Enrico; Tizzani, Maria; Porrino, Giulio; Ferreri, Enrico; Volpicelli, Giovanni; Balzaretti, Paolo; Banderali, Alessandra; Iacobucci, Antonello; Locatelli, Stefania; Casoli, Giovanna; Stone, Michael B; Maule, Milena M; Baldi, Ileana; Merletti, Franco; Cibinel, Gian Alfonso; Baron, Paolo; Battista, Stefania; Buonafede, Giuseppina; Busso, Valeria; Conterno, Andrea; Del Rizzo, Paola; Ferrera, Patrizia; Pecetto, Paolo Fascio; Moiraghi, Corrado; Morello, Fulvio; Steri, Fabio; Ciccone, Giovannino; Calasso, Cosimo; Caserta, Mimma A; Civita, Marina; Condo', Carmen; D'Alessandro, Vittorio; Del Colle, Sara; Ferrero, Stefania; Griot, Giulietta; Laurita, Emanuela; Lazzero, Alberto; Lo Curto, Francesca; Michelazzo, Marianna; Nicosia, Vincenza; Palmari, Nicola; Ricchiardi, Alberto; Rolfo, Andrea; Rostagno, Roberto; Bar, Fabrizio; Boero, Enrico; Frascisco, Mauro; Micossi, Ilaria; Mussa, Alessandro; Stefanone, Valerio; Agricola, Renzo; Cordero, Gabriele; Corradi, Federica; Runzo, Cristina; Soragna, Aldo; Sciullo, Daniela; Vercillo, Domenico; Allione, Attilio; Artana, Nicoletta; Corsini, Fabrizio; Dutto, Luca; Lauria, Giuseppe; Morgillo, Teresa; Tartaglino, Bruno; Bergandi, Daniela; Cassetta, Ilaria; Masera, Clotilde; Garrone, Mario; Ghiselli, Gianluca; Ausiello, Livia; Barutta, Letizia; Bernardi, Emanuele; Bono, Alessia; Forno, Daniela; Lamorte, Alessandro; Lison, Davide; Lorenzati, Bartolomeo; Maggio, Elena; Masi, Ilaria; Maggiorotto, Matteo; Novelli, Giulia; Panero, Francesco; Perotto, Massimo; Ravazzoli, Marco; Saglio, Elisa; Soardo, Flavia; Tizzani, Alessandra; Tizzani, Pietro; Tullio, Mattia; Ulla, Marco; Romagnoli, Elisa

    2015-07-01

    Lung ultrasonography (LUS) has emerged as a noninvasive tool for the differential diagnosis of pulmonary diseases. However, its use for the diagnosis of acute decompensated heart failure (ADHF) still raises some concerns. We tested the hypothesis that an integrated approach implementing LUS with clinical assessment would have higher diagnostic accuracy than a standard workup in differentiating ADHF from noncardiogenic dyspnea in the ED. We conducted a multicenter, prospective cohort study in seven Italian EDs. For patients presenting with acute dyspnea, the emergency physician was asked to categorize the diagnosis as ADHF or noncardiogenic dyspnea after (1) the initial clinical assessment and (2) after performing LUS ("LUS-implemented" diagnosis). All patients also underwent chest radiography. After discharge, the cause of each patient's dyspnea was determined by independent review of the entire medical record. The diagnostic accuracy of the different approaches was then compared. The study enrolled 1,005 patients. The LUS-implemented approach had a significantly higher accuracy (sensitivity, 97% [95% CI, 95%-98.3%]; specificity, 97.4% [95% CI, 95.7%-98.6%]) in differentiating ADHF from noncardiac causes of acute dyspnea than the initial clinical workup (sensitivity, 85.3% [95% CI, 81.8%-88.4%]; specificity, 90% [95% CI, 87.2%-92.4%]), chest radiography alone (sensitivity, 69.5% [95% CI, 65.1%-73.7%]; specificity, 82.1% [95% CI, 78.6%-85.2%]), and natriuretic peptides (sensitivity, 85% [95% CI, 80.3%-89%]; specificity, 61.7% [95% CI, 54.6%-68.3%]; n = 486). Net reclassification index of the LUS-implemented approach compared with standard workup was 19.1%. The implementation of LUS with the clinical evaluation may improve accuracy of ADHF diagnosis in patients presenting to the ED. Clinicaltrials.gov; No.: NCT01287429; URL: www.clinicaltrials.gov.

  11. Sensitivity and Specificity of Swedish Interactive Threshold Algorithm and Standard Full Threshold Perimetry in Primary Open-angle Glaucoma.

    PubMed

    Bamdad, Shahram; Beigi, Vahid; Sedaghat, Mohammad Reza

    2017-01-01

    Perimetry is one of the mainstays in glaucoma diagnosis and treatment. Various strategies offer different accuracies in glaucoma testing. Our aim was to determine and compare the diagnostic sensitivity and specificity of Swedish Interactive Threshold Algorithm (SITA) Fast and Standard Full Threshold (SFT) strategies of the Humphrey Field Analyzer (HFA) in identifying patients with visual field defect in glaucoma disease. This prospective observational case series study was conducted in a university-based eye hospital. A total of 37 eyes of 20 patients with glaucoma were evaluated using the central 30-2 program and both the SITA Fast and SFT strategies. Both strategies were performed for each strategy in each session and for four times in a 2-week period. Data were analyzed using the Student's t-test, analysis of variance, and chi-square test. The SITA Fast and SFT strategies had similar sensitivity of 93.3%. The specificity of SITA Fast and SFT strategies was 57.4% and 71.4% respectively. The mean duration of SFT tests was 14.6 minutes, and that of SITA Fast tests was 5.45 minutes (a statistically significant 62.5% reduction). In gray scale plots, visual field defect was less deep in SITA Fast than in SFT; however, more points had significant defect (p < 0.5% and p < 1%) in pattern deviation plots in SITA Fast than in SFT; these differences were not clinically significant. In conclusion, the SITA Fast strategy showed higher sensitivity for detection of glaucoma compared to the SFT strategy, yet with reduced specificity; however, the shorter test duration makes it a more acceptable choice in many clinical situations, especially for children, elderly, and those with musculoskeletal diseases.

  12. Sensitivity and specificity of the amer dizziness diagnostic scale (adds) for patients with vestibular disorders.

    PubMed

    Al Saif, Amer; Alsenany, Samira

    2015-01-01

    [Purpose] To investigate the sensitivity and specificity of a newly developed diagnostic tool, the Amer Dizziness Diagnostic Scale (ADDS), to evaluate and differentially diagnose vestibular disorder and to identify the strengths and weaknesses of the scale and its usefulness in clinical practice. [Subjects and Methods] Two hundred subjects of both genders (72 males, 128 females) aged between 18 to 60 (49.5±7.8) who had a history of vertigo and/or dizziness symptoms for this previous two weeks or less were recruited for the study. All subjects were referred by otolaryngologists, neurologists or family physicians in and around Jeddah, Kingdom of Saudi Arabia. On the first clinic visit, all the patients were evaluated once using the ADDS, following which they underwent routine testing of clinical signs and symptoms, audiometry, and a neurological examination, coupled with tests of Vestibulo-Ocular Reflex function, which often serves as the "gold standard" for determining the probability of a vestibular deficit. [Results] The results show that the ADDS strongly correlated with "true-positive" and "true-negative" responses for determining the probability of a vestibular disorder (r =0.95). A stepwise linear regression was conducted and the results indicate that the ADDS was a significant predictor of "true-positive" and "true-negative" responses in vestibular disorders (R(2) =0.90). Approximately 90% of the variability in the vestibular gold standard test was explained by its relationship to the ADDS. Moreover, the ADDS was found to have a sensitivity of 96% and a specificity of 96%. [Conclusion] This study showed that the Amer Dizziness Diagnostic Scale has high sensitivity and specificity and that it can be used as a method of differential diagnosis for patients with vestibular disorders.

  13. Diagnostic capability of scanning laser polarimetry with variable cornea compensator in Indian patients with early primary open-angle glaucoma.

    PubMed

    Parikh, Rajul S; Parikh, Shefali R; Kumar, Rajesh S; Prabakaran, S; Babu, J Gansesh; Thomas, Ravi

    2008-07-01

    To evaluate the diagnostic ability of scanning laser polarimetry (GDx variable corneal compensator [VCC]) for early glaucoma in Asian Indian eyes. Cross-sectional observational study. Two groups of patients (early glaucoma and normal) who satisfied the inclusion and exclusion criteria were included. Early glaucoma was diagnosed in presence of open angles, characteristic glaucomatous optic disc changes correlating with the visual field (VF) on automated perimetry (VF defect fulfilling at least 2 of 3 Anderson and Patella's criteria with mean deviation >or= -6 decibels). Normal subjects had visual acuity >or= 20/30 and intraocular pressure < 22 mmHg, with a normal optic disc and fields and no ocular abnormality. All patients underwent complete ophthalmic evaluation, including VF examination (24-2/30-2 Swedish interactive threshold algorithm standard program) and imaging with GDx VCC. Sensitivity, specificity, positive predictive value and negative predictive value, area under the receiving operating characteristic curve, and likelihood ratios (LRs) were calculated for various GDx VCC parameters. Seventy-four eyes (74 patients) with early glaucoma and 104 eyes (104 normal subjects) were enrolled. TSNIT Std Dev (temporal-superior-nasal-inferior-temporal standard deviation) had the best combination of sensitivity and specificity-61.3 and 95.2, respectively-followed by nerve fiber index score > 50 (sensitivity, 52.7%; specificity, 99%). Nerve fiber index score > 50 had positive and negative predictive values of 74.3% and 97.6%, respectively, for an assumed glaucoma prevalence of 5%. Nerve fiber index score > 50 had a positive LR (+LR) of 54.8 for early glaucoma. GDx VCC has moderate sensitivity, with high specificity, in the diagnosis of early glaucoma. The high +LR for the nerve fiber index score can provide valuable diagnostic information for individual patients.

  14. Circulating antigen tests and urine reagent strips for diagnosis of active schistosomiasis in endemic areas

    PubMed Central

    Ochodo, Eleanor A; Gopalakrishna, Gowri; Spek, Bea; Reitsma, Johannes B; van Lieshout, Lisette; Polman, Katja; Lamberton, Poppy; Bossuyt, Patrick Mm; Leeflang, Mariska Mg

    2015-01-01

    Background Point-of-care (POC) tests for diagnosing schistosomiasis include tests based on circulating antigen detection and urine reagent strip tests. If they had sufficient diagnostic accuracy they could replace conventional microscopy as they provide a quicker answer and are easier to use. Objectives To summarise the diagnostic accuracy of: a) urine reagent strip tests in detecting active Schistosoma haematobium infection, with microscopy as the reference standard; and b) circulating antigen tests for detecting active Schistosoma infection in geographical regions endemic for Schistosoma mansoni or S. haematobium or both, with microscopy as the reference standard. Search methods We searched the electronic databases MEDLINE, EMBASE, BIOSIS, MEDION, and Health Technology Assessment (HTA) without language restriction up to 30 June 2014. Selection criteria We included studies that used microscopy as the reference standard: for S. haematobium, microscopy of urine prepared by filtration, centrifugation, or sedimentation methods; and for S. mansoni, microscopy of stool by Kato-Katz thick smear. We included studies on participants residing in endemic areas only. Data collection and analysis Two review authors independently extracted data, assessed quality of the data using QUADAS-2, and performed meta-analysis where appropriate. Using the variability of test thresholds, we used the hierarchical summary receiver operating characteristic (HSROC) model for all eligible tests (except the circulating cathodic antigen (CCA) POC for S. mansoni, where the bivariate random-effects model was more appropriate). We investigated heterogeneity, and carried out indirect comparisons where data were sufficient. Results for sensitivity and specificity are presented as percentages with 95% confidence intervals (CI). Main results We included 90 studies; 88 from field settings in Africa. The median S. haematobium infection prevalence was 41% (range 1% to 89%) and 36% for S. mansoni (range 8% to 95%). Study design and conduct were poorly reported against current standards. Tests for S. haematobium Urine reagent test strips versus microscopy Compared to microscopy, the detection of microhaematuria on test strips had the highest sensitivity and specificity (sensitivity 75%, 95% CI 71% to 79%; specificity 87%, 95% CI 84% to 90%; 74 studies, 102,447 participants). For proteinuria, sensitivity was 61% and specificity was 82% (82,113 participants); and for leukocyturia, sensitivity was 58% and specificity 61% (1532 participants). However, the difference in overall test accuracy between the urine reagent strips for microhaematuria and proteinuria was not found to be different when we compared separate populations (P = 0.25), or when direct comparisons within the same individuals were performed (paired studies; P = 0.21). When tests were evaluated against the higher quality reference standard (when multiple samples were analysed), sensitivity was marginally lower for microhaematuria (71% vs 75%) and for proteinuria (49% vs 61%). The specificity of these tests was comparable. Antigen assay Compared to microscopy, the CCA test showed considerable heterogeneity; meta-analytic sensitivity estimate was 39%, 95% CI 6% to 73%; specificity 78%, 95% CI 55% to 100% (four studies, 901 participants). Tests for S. mansoni Compared to microscopy, the CCA test meta-analytic estimates for detecting S. mansoni at a single threshold of trace positive were: sensitivity 89% (95% CI 86% to 92%); and specificity 55% (95% CI 46% to 65%; 15 studies, 6091 participants) Against a higher quality reference standard, the sensitivity results were comparable (89% vs 88%) but specificity was higher (66% vs 55%). For the CAA test, sensitivity ranged from 47% to 94%, and specificity from 8% to 100% (4 studies, 1583 participants). Authors' conclusions Among the evaluated tests for S. haematobium infection, microhaematuria correctly detected the largest proportions of infections and non-infections identified by microscopy. The CCA POC test for S. mansoni detects a very large proportion of infections identified by microscopy, but it misclassifies a large proportion of microscopy negatives as positives in endemic areas with a moderate to high prevalence of infection, possibly because the test is potentially more sensitive than microscopy. Plain Language Summary How well do point-of-care tests detect Schistosoma infections in people living inendemic areas? Schistosomiasis, also known as bilharzia, is a parasitic disease common in the tropical and subtropics. Point-of-care tests and urine reagent strip tests are quicker and easier to use than microscopy. We estimate how well these point-of-care tests are able to detect schistosomiasis infections compared with microscopy. We searched for studies published in any language up to 30 June 2014, and we considered the study’s risk of providing biased results. What do the results say? We included 90 studies involving almost 200,000 people, with 88 of these studies carried out in Africa in field settings. Study design and conduct were poorly reported against current expectations. Based on our statistical model, we found: • Among the urine strips for detecting urinary schistosomiasis, the strips for detecting blood were better than those detecting protein or white cells (sensitivity and specificity for blood 75% and 87%; for protein 61% and 82%; and for white cells 58% and 61%, respectively). • For urinary schistosomiasis, the parasite antigen test performance was worse (sensitivity, 39% and specificity, 78%) than urine strips for detecting blood. • For intestinal schistosomiasis, the parasite antigen urine test, detected many infections identified by microscopy but wrongly labelled many uninfected people as sick (sensitivity, 89% and specificity, 55%). What are the consequences of using these tests? If we take 1000 people, of which 410 have urinary schistosomiasis on microscopy testing, then using the strip detecting blood in the urine would misclassify 77 uninfected people as infected, and thus may receive unnecessary treatment; and it would wrongly classify 102 infected people as uninfected, who thus may not receive treatment. If we take 1000 people, of which 360 have intestinal schistosomiasis on microscopy testing, then the antigen test would misclassify 288 uninfected people as infected. These people may be given unnecessary treatment. This test also would wrongly classify 40 infected people as uninfected who thus may not receive treatment. Conclusion of review For urinary schistosomiasis, the urine strip for detecting blood leads to some infected people being missed and some non-infected people being diagnosed with the condition, but is better than the protein or white cell tests. The parasite antigen test is not accurate. For intestinal schistosomiasis, the parasite antigen urine test can wrongly classify many uninfected people as infected. PMID:25758180

  15. Point of care diagnosis of multiple schistosome parasites: Species-specific DNA detection in urine by loop-mediated isothermal amplification (LAMP).

    PubMed

    Lodh, Nilanjan; Mikita, Kei; Bosompem, Kwabena M; Anyan, William K; Quartey, Joseph K; Otchere, Joseph; Shiff, Clive J

    2017-09-01

    Schistosomes are easily transmitted and high chance of repeat infection, so if control strategies based on targeted mass drug administration (MDA) are to succeed it is essential to have a test that is sensitive, accurate and simple to use. It is known and regularly demonstrated that praziquantel does not always eliminate an infection so in spite of the successes of control programs a residual of the reservoir survives to re-infect snails. The issue of diagnostic sensitivity becomes more critical in the assessment of program effectiveness. While serology, such as antigen capture tests might improve sensitivity, it has been shown that the presence of species-specific DNA fragments will indicate, most effectively, the presence of active parasites. Polymerase chain reaction (PCR) can amplify and detect DNA from urine residue captured on Whatman No. 3 filter paper that is dried after filtration. Previously we have detected S. mansoni and S. haematobium parasite-specific small repeat DNA fragment from filtered urine on filter paper by PCR. In the current study, we assessed the efficacy of detection of 86 urine samples for either or both schistosome parasites by PCR and loop-mediated isothermal amplification (LAMP) that were collected from a low to moderate transmission area in Ghana. Two different DNA extraction methods, standard extraction kit and field usable LAMP-PURE kit were also evaluated by PCR and LAMP amplification. With S. haematobium LAMP amplification for both extractions showed similar sensitivity and specificity when compared with PCR amplification (100%) verified by gel electrophoresis. For S. mansoni sensitivity was highest for LAMP amplification (100%) for standard extraction than PCR and LAMP with LAMP-PURE (99% and 94%). The LAMP-PURE extraction produced false negatives, which require further investigation for this field usable extraction kit. Overall high positive and negative predictive values (90% - 100%) for both species demonstrated a highly robust approach. The LAMP approach is close to point of care use and equally sensitive and specific to detection of species-specific DNA by PCR. LAMP can be an effective means to detect low intensity infection due to its simplicity and minimal DNA extraction requirement. This will enhance the effectiveness of surveillance and MDA control programs of schistosomiasis. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. SLOWLY REPEATED EVOKED PAIN (SREP) AS A MARKER OF CENTRAL SENSITIZATION IN FIBROMYALGIA: DIAGNOSTIC ACCURACY AND RELIABILITY IN COMPARISON WITH TEMPORAL SUMMATION OF PAIN.

    PubMed

    de la Coba, Pablo; Bruehl, Stephen; Gálvez-Sánchez, Carmen María; Reyes Del Paso, Gustavo A

    2018-05-01

    This study examined the diagnostic accuracy and test-retest reliability of a novel dynamic evoked pain protocol (slowly repeated evoked pain; SREP) compared to temporal summation of pain (TSP), a standard index of central sensitization. Thirty-five fibromyalgia (FM) and 30 rheumatoid arthritis (RA) patients completed, in pseudorandomized order, a standard mechanical TSP protocol (10 stimuli of 1s duration at the thenar eminence using a 300g monofilament with 1s interstimulus interval) and the SREP protocol (9 suprathreshold pressure stimuli of 5s duration applied to the fingernail with a 30s interstimulus interval). In order to evaluate reliability for both protocols, they were repeated in a second session 4-7 days later. Evidence for significant pain sensitization over trials (increasing pain intensity ratings) was observed for SREP in FM (p<.001) but not in RA (p=.35), whereas significant sensitization was observed in both diagnostic groups for the TSP protocol (p's<.008). Compared to TSP, SREP demonstrated higher overall diagnostic accuracy (87.7% vs. 64.6%), greater sensitivity (0.89 vs. 0.57), and greater specificity (0.87 vs. 0.73) in discriminating between FM and RA patients. Test-retest reliability of SREP sensitization was good in FM (ICCs: 0.80), and moderate in RA (ICC: 0.68). SREP seems to be a dynamic evoked pain index tapping into pain sensitization that allows for greater diagnostic accuracy in identifying FM patients compared to a standard TSP protocol. Further research is needed to study mechanisms underlying SREP and the potential utility of adding SREP to standard pain evaluation protocols.

  17. An optimized IFN-γ ELISpot assay for the sensitive and standardized monitoring of CMV protein-reactive effector cells of cell-mediated immunity.

    PubMed

    Barabas, Sascha; Spindler, Theresa; Kiener, Richard; Tonar, Charlotte; Lugner, Tamara; Batzilla, Julia; Bendfeldt, Hanna; Rascle, Anne; Asbach, Benedikt; Wagner, Ralf; Deml, Ludwig

    2017-03-07

    In healthy individuals, Cytomegalovirus (CMV) infection is efficiently controlled by CMV-specific cell-mediated immunity (CMI). Functional impairment of CMI in immunocompromized individuals however can lead to uncontrolled CMV replication and severe clinical complications. Close monitoring of CMV-specific CMI is therefore clinically relevant and might allow a reliable prognosis of CMV disease as well as assist personalized therapeutic decisions. Objective of this work was the optimization and technical validation of an IFN-γ ELISpot assay for a standardized, sensitive and reliable quantification of CMV-reactive effector cells. T-activated® immunodominant CMV IE-1 and pp65 proteins were used as stimulants. All basic assay parameters and reagents were tested and optimized to establish a user-friendly protocol and maximize the signal-to-noise ratio of the ELISpot assay. Optimized and standardized ELISpot revealed low intra-assay, inter-assay and inter-operator variability (coefficient of variation CV below 22%) and CV inter-site was lower than 40%. Good assay linearity was obtained between 6 × 10 4 and 2 × 10 5 PBMC per well upon stimulation with T-activated® IE-1 (R 2  = 0.97) and pp65 (R 2  = 0.99) antigens. Remarkably, stimulation of peripheral blood mononuclear cells (PBMC) with T-activated® IE-1 and pp65 proteins resulted in the activation of a broad range of CMV-reactive effector cells, including CD3 + CD4 + (Th), CD3 + CD8 + (CTL), CD3 - CD56 + (NK) and CD3 + CD56 + (NKT-like) cells. Accordingly, the optimized IFN-γ ELISpot assay revealed very high sensitivity (97%) in a cohort of 45 healthy donors, of which 32 were CMV IgG-seropositive. The combined use of T-activated® IE-1 and pp65 proteins for the stimulation of PBMC with the optimized IFN-γ ELISpot assay represents a highly standardized, valuable tool to monitor the functionality of CMV-specific CMI with great sensitivity and reliability.

  18. A Serological Point-of-Care Test for the Detection of IgG Antibodies against Ebola Virus in Human Survivors.

    PubMed

    Brangel, Polina; Sobarzo, Ariel; Parolo, Claudio; Miller, Benjamin S; Howes, Philip D; Gelkop, Sigal; Lutwama, Julius J; Dye, John M; McKendry, Rachel A; Lobel, Leslie; Stevens, Molly M

    2018-01-23

    Ebola virus disease causes widespread and highly fatal epidemics in human populations. Today, there is still great need for point-of-care tests for diagnosis, patient management and surveillance, both during and post outbreaks. We present a point-of-care test comprising an immunochromatographic strip and a smartphone reader, which detects and semiquantifies Ebola-specific antibodies in human survivors. We developed a Sudan virus glycoprotein monoplex platform and validated it using sera from 90 human survivors and 31 local noninfected controls. The performance of the glycoprotein monoplex was 100% sensitivity and 98% specificity compared to standard whole antigen enzyme-linked immunosorbent assay (ELISA), and it was validated with freshly collected patient samples in Uganda. Moreover, we constructed a multiplex test for simultaneous detection of antibodies against three recombinant Sudan virus proteins. A pilot study comprising 15 survivors and 5 noninfected controls demonstrated sensitivity and specificity of 100% compared to standard ELISA. Finally, we developed a second multiplex subtype assay for the identification of exposure to three related EVD species: Sudan virus, Bundibugyo virus and Ebola virus (formerly Zaire) using recombinant viral glycoprotein. This multiplex test could distinguish between the host's immunity to specific viral species and identify cross-reactive immunity. These developed serological platforms consisted of capture ligands with high specificity and sensitivity, in-house developed strips and a compatible smartphone application. These platforms enabled rapid and portable testing, data storage and sharing as well as geographical tagging of the tested individuals in Uganda. This platform holds great potential as a field tool for diagnosis, vaccine development, and therapeutic evaluation.

  19. Diagnosis of Pulmonary Tuberculosis in HIV-Positive Patients by Microscopic Observation Drug Susceptibility Assay ▿

    PubMed Central

    Ha, Dang Thi Minh; Lan, Nguyen Thi Ngoc; Kiet, Vo Sy; Wolbers, Marcel; Hang, Hoang Thi Thanh; Day, Jeremy; Hien, Nguyen Quang; Tien, Nguyen Anh; An, Pham Thuy; Anh, Truong Thi; Oanh, Do Thi Tuong; Hoa, Chau Luong; Chau, Nguyen Thi Minh; Hai, Nguyen Ngoc; Binh, Ngo Thanh; Ngoc, Le Hong; Phuong, Doan Thanh; Quyet, Tran Van; Tuyen, Nguyen Thi Bich; Ha, Vo Thi; Nho, Nguyen Thi; Hoa, Dai Viet; Anh, Phan Thi Hoang; Dung, Nguyen Huy; Farrar, Jeremy; Caws, Maxine

    2010-01-01

    The microscopic observation drug susceptibility assay (MODS) is a novel and promising test for the early diagnosis of tuberculosis (TB). We evaluated the MODS assay for the early diagnosis of TB in HIV-positive patients presenting to Pham Ngoc Thach Hospital for Tuberculosis and Lung Diseases in southern Vietnam. A total of 738 consecutive sputum samples collected from 307 HIV-positive individuals suspected of TB were tested by smear, MODS, and the mycobacteria growth indicator tube method (MGIT). The diagnostic sensitivity and specificity of MODS compared to the microbiological gold standard (either smear or MGIT) were 87 and 93%, respectively. The sensitivities of smear, MODS, and MGIT were 57, 71, and 75%, respectively, against clinical gold standard (MODS versus smear, P < 0.001; MODS versus MGIT, P = 0.03). The clinical gold standard was defined as patients who had a clinical examination and treatment consistent with TB, with or without microbiological confirmation. For the diagnosis of smear-negative patients, the sensitivities of MODS and MGIT were 38 and 45%, respectively (P = 0.08). The median times to detection using MODS and MGIT were 8 and 11 days, respectively, and they were 11 and 17 days, respectively, for smear-negative samples. The original bacterial/fungal contamination rate of MODS was 1.1%, while it was 2.6% for MGIT. The cross-contamination rate of MODS was 4.7%. In conclusion, MODS is a sensitive, specific, and rapid test that is appropriate for the detection of HIV-associated TB; its cost and ease of use make it particularly useful in resource-limited settings. PMID:20926704

  20. [Hospitalizations for ambulatory care-sensitive conditions: validation study at a Hospital Information System (SIH) in the Federal District, Brazil, in 2012].

    PubMed

    Cavalcante, Danyelle Monteiro; de Oliveira, Maria Regina Fernandes; Rehem, Tânia Cristina Morais Santa Bárbara

    2016-03-01

    This study analyzes hospitalizations due to ambulatory care-sensitive conditions with a focus on infectious and parasitic diseases (IPDs) and validates the Hospital Information System, Brazilian Unified National Health System (SIH/SUS) for recording hospitalizations due to ambulatory care-sensitive conditions in a hospital in the Federal District, Brazil, in 2012. The study estimates the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the SIH for recording hospitalizations due to ambulatory care-sensitive conditions, with the patient's medical file as the gold standard. There were 1,604 hospitalizations for hospitalizations due to ambulatory care-sensitive conditions (19.6%, 95%CI: 18.7-20.5), and the leading IPDs were renal and urinary tract infection, infection of the skin and subcutaneous tissue, and infectious gastroenteritis. IPDs were the leading cause of hospitalization in the 20 to 29-year age bracket and caused 28 deaths. Sensitivity was 70.1% (95%CI: 60.5-79.7), specificity 88.4% (95%CI: 85.6-91.2), PPV = 51.7% (95%CI: 42.7-60.7), and NPV = 94.3% (95%CI: 92.2-96.4). The findings for admissions due to ACSCs in this hospital were similar to those of other studies, featuring admissions for IPDs. The SIH/SUS database was more specific than sensitive.

  1. Quantitative fucK gene polymerase chain reaction on sputum and nasopharyngeal secretions to detect Haemophilus influenzae pneumonia.

    PubMed

    Abdeldaim, Guma M K; Strålin, Kristoffer; Olcén, Per; Blomberg, Jonas; Mölling, Paula; Herrmann, Björn

    2013-06-01

    A quantitative polymerase chain reaction (PCR) for the fucK gene was developed for specific detection of Haemophilus influenzae. The method was tested on sputum and nasopharyngeal aspirate (NPA) from 78 patients with community-acquired pneumonia (CAP). With a reference standard of sputum culture and/or serology against the patient's own nasopharyngeal isolate, H. influenzae etiology was detected in 20 patients. Compared with the reference standard, fucK PCR (using the detection limit 10(5) DNA copies/mL) on sputum and NPA showed a sensitivity of 95.0% (19/20) in both cases, and specificities of 87.9% (51/58) and 89.5% (52/58), respectively. In a receiver operating characteristic curve analysis, sputum fucK PCR was found to be significantly superior to sputum P6 PCR for detection of H. influenzae CAP. NPA fucK PCR was positive in 3 of 54 adult controls without respiratory symptoms. In conclusion, quantitative fucK real-time PCR provides a sensitive and specific identification of H. influenzae in respiratory secretions. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. Performance of the 2015 American College of Rheumatology/European League Against Rheumatism gout classification criteria in Thai patients.

    PubMed

    Louthrenoo, Worawit; Jatuworapruk, Kanon; Lhakum, Panomkorn; Pattamapaspong, Nuttaya

    2017-05-01

    To evaluate the sensitivity and specificity of the 2015 American College of Rheumatology/European League Against Rheumatism (ACR/EULAR) gout classification criteria in Thai patients presenting with acute arthritis in a real-life setting. Data were analyzed on consecutive patients presenting with arthritis of less than 2 weeks duration. Sensitivity and specificity were calculated by using the presence of monosodium urate (MSU) crystals in the synovial fluid or tissue aspirate as gold standard for gout diagnosis. Subgroup analysis was performed in patients with early disease (≤2 years), established disease (>2 years), and those without tophus. Additional analysis also was performed in non-tophaceous gout patients, and patients with acute calcium pyrophosphate dihydrate crystal arthritis were used as controls. One hundred and nine gout and 74 non-gout patients participated in this study. Full ACR/EULAR classification criteria had sensitivity and specificity of 90.2 and 90.0%, respectively; and 90.2 and 85.0%, respectively, when synovial fluid microscopy was excluded. Clinical-only criteria yielded sensitivity and specificity of 79.8 and 87.8%, respectively. The criteria performed well among patients with early and non-tophaceous disease, but had lower specificity in patients with established disease. The variation of serum uric acid level was a major limitation of the classification criteria. The ACR/EULAR classification criteria had high sensitivity and specificity in Thai patients presenting with acute arthritis, even when clinical criteria alone were used.

  3. Reducing animal experimentation in foot-and-mouth disease vaccine potency tests.

    PubMed

    Reeve, Richard; Cox, Sarah; Smitsaart, Eliana; Beascoechea, Claudia Perez; Haas, Bernd; Maradei, Eduardo; Haydon, Daniel T; Barnett, Paul

    2011-07-26

    The World Organisation for Animal Health (OIE) Terrestrial Manual and the European Pharmacopoeia (EP) still prescribe live challenge experiments for foot-and-mouth disease virus (FMDV) immunogenicity and vaccine potency tests. However, the EP allows for other validated tests for the latter, and specifically in vitro tests if a "satisfactory pass level" has been determined; serological replacements are also currently in use in South America. Much research has therefore focused on validating both ex vivo and in vitro tests to replace live challenge. However, insufficient attention has been given to the sensitivity and specificity of the "gold standard"in vivo test being replaced, despite this information being critical to determining what should be required of its replacement. This paper aims to redress this imbalance by examining the current live challenge tests and their associated statistics and determining the confidence that we can have in them, thereby setting a standard for candidate replacements. It determines that the statistics associated with the current EP PD(50) test are inappropriate given our domain knowledge, but that the OIE test statistics are satisfactory. However, it has also identified a new set of live animal challenge test regimes that provide similar sensitivity and specificity to all of the currently used OIE tests using fewer animals (16 including controls), and can also provide further savings in live animal experiments in exchange for small reductions in sensitivity and specificity. Copyright © 2011 Elsevier Ltd. All rights reserved.

  4. Exploring physical and chemical factors influencing the properties of recombinant prion protein and the real-time quaking-induced conversion (RT-QuIC) assay.

    PubMed

    Cheng, Keding; Sloan, Angela; Avery, Kristen M; Coulthart, Michael; Carpenter, Michael; Knox, J David

    2014-01-01

    Real-time quaking-induced conversion (RT-QuIC), a highly specific and sensitive assay able to detect low levels of the disease-inducing isoform of the prion protein (PrP(d)) in brain tissue biopsies and cerebral spinal fluid, has great potential to become a method for diagnosing prion disease ante mortem. In order to standardize the assay method for routine analysis, an understanding of how physical and chemical factors affect the stability of the recombinant prion protein (rPrP) substrate and the RT-QuIC assay's sensitivity, specificity, and reproducibility is required. In this study, using sporadic Creutzfeldt-Jakob Disease brain homogenate to seed the reactions and an in vitro-expressed recombinant prion protein, hamster rPrP, as the substrate, the following factors affecting the RT-QuIC assay were examined: salt and substrate concentrations, substrate storage, and pH. Results demonstrated that both the generation of the quality and quantities of rPrP substrate critical to the reaction, as well as the RT-QuIC reaction itself required strict adherence to specific physical and chemical conditions. Once optimized, the RT-QuIC assay was confirmed to be a very specific and sensitive assay method for sCJD detection. Findings in this study indicate that further optimization and standardization of RT-QuIC assay is required before it can be adopted as a routine diagnostic test.

  5. Diagnostic accuracy of a smartphone electrocardiograph in dogs: Comparison with standard 6-lead electrocardiography.

    PubMed

    Vezzosi, T; Buralli, C; Marchesotti, F; Porporato, F; Tognetti, R; Zini, E; Domenech, O

    2016-10-01

    The diagnostic accuracy of a smartphone electrocardiograph (ECG) in evaluating heart rhythm and ECG measurements was evaluated in 166 dogs. A standard 6-lead ECG was acquired for 1 min in each dog. A smartphone ECG tracing was simultaneously recorded using a single-lead bipolar ECG recorder. All ECGs were reviewed by one blinded operator, who judged if tracings were acceptable for interpretation and assigned an electrocardiographic diagnosis. Agreement between smartphone and standard ECG in the interpretation of tracings was evaluated. Sensitivity and specificity for the detection of arrhythmia were calculated for the smartphone ECG. Smartphone ECG tracings were interpretable in 162/166 (97.6%) tracings. A perfect agreement between the smartphone and standard ECG was found in detecting bradycardia, tachycardia, ectopic beats and atrioventricular blocks. A very good agreement was found in detecting sinus rhythm versus non-sinus rhythm (100% sensitivity and 97.9% specificity). The smartphone ECG provided tracings that were adequate for analysis in most dogs, with an accurate assessment of heart rate, rhythm and common arrhythmias. The smartphone ECG represents an additional tool in the diagnosis of arrhythmias in dogs, but is not a substitute for a 6-lead ECG. Arrhythmias identified by the smartphone ECG should be followed up with a standard ECG before making clinical decisions. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Obesity in Korean pre-adolescent school children: comparison of various anthropometric measurements based on bioelectrical impedance analysis.

    PubMed

    Yoo, S; Lee, S-Y; Kim, K-N; Sung, E

    2006-07-01

    To examine the relationships between body mass index (BMI), percentage-weight-for-height (PWH) and percentage body fat (PBF), and to compare their validity based on PBF with the BMI criteria of International Obesity Task Force (IOTF) for childhood obesity in Korean pre-adolescent school children. Statistical comparative analysis for anthropometric measures. Korean pre-adolescent children (438 boys and 454 girls, aged 8-12 years, mean BMI 19.5+/-3.4 kg/m2). Body mass index and PWH were calculated as body size indices from height and weight. Hand-to-foot bioelectrical impedance analysis (BIA) was performed to obtain PBF values, with obese children defined as PBF above 35%. Sensitivity and specificity were displayed with the gold standard of PBF, and receiver operating characteristic (ROC) curves were used to assess the performance of BMI and PWH in detecting obesity. The prevalence of obesity varied by the criteria: 18.8% by Korean BMI standards for 95 percentile, 11% by the IOTF-BMI 30 kg/m2 and 29.4% by Korean PWH cutoffs. Body mass index and PWH were significantly correlated with PBF after adjusting for age, 0.910 (P<0.01) and 0.915 (P<0.01), respectively. The sensitivity and specificity of the PWH cutoffs were 0.909 and 0.882, respectively. The local BMI 95 percentiles had lower sensitivity (0.714) and specificity (0.790). The IOTF-BMI definition showed much lower sensitivity (0.457) and higher specificity (0.990). The BMI cutoffs corresponding with the highest accuracy were smaller than IOTF-BMI 30 kg/m2 for all age groups in both boys and girls. The prevalence of obesity among Korean pre-adolescent children widely varied according to the diagnostic criteria applied. Universally recommended cutoffs for children by IOTF showed the lowest sensitivity among the criteria used, and may therefore underestimate obesity in this population.

  7. Cytological diagnostic of lymphadenitis tuberculosis by eosinophilic material

    NASA Astrophysics Data System (ADS)

    Delyuzar; Amir, Z.; Kusumawati, L.

    2018-03-01

    AFB sputum and chest X-ray are used to identify patients with pulmonary TB. For extrapulmonary TB, fine needle aspiration cytology is needed, even though occasionally found not atypical feature in the form of eosinophilic material with dark brown particles, suspected as TB. This research was to show that eosinophilic material with dark brown particles is accurate as new criteria for the cytological diagnosis of TB. By performing fine needle aspiration biopsy stained with Giemsa, if an eosinophilic material with dark brown particles was encountered, we continued with Ziehl-Neelsen AFB stain and confirmed with PCR. To assess accuracy, we used a diagnostic test to evaluate sensitivity and specificity of eosinophilic material with dark brown particles by using AFB and PCR as the gold standard. The sensitivity and specificity of cytological diagnosis in tuberculosis of eosinophilic material with dark brown particles were 93.65% and 70.99%, respectively if confirmed with AFB. On the other hand, if confirmed with PCR using Mycobacterium tuberculosis DNA, the sensitivity and specificity were 98.95% and 96.79%, respectively. In conclusion, eosinophilic masses with dark brown particles is accurate as new criteria of TB diagnostic cytology with high sensitivity and specificity confirmed with AFB and PCR test.

  8. [Flicker comparison of optic disc photographs: sensitivity and specificity].

    PubMed

    Funk, Jens; Lagrèze, Wolf; Zeyen, Thierry

    2002-12-01

    Examination and documentation of the optic nerve head are essential in monitoring glaucoma patients. Even minor changes in optic nerve head morphology can be visualised using the so-called flicker test: Two optic nerve head photographs, taken at consecutive examinations, are superimposed by projection. When occluding the pictures in a rapid alternating fashion, changes in optic nerve head morphology appear as motion. In this study, we evaluated sensitivity and specificity of the flicker test. A set of 33 pairs of serial optic disc slides was used as gold standard. These 33 pairs had been classified earlier by 3 independent groups of experts. 23 had been classified as "no change over time", 10 had been classified as "change". All 33 pairs were now evaluated by flicker comparison in a masked fashion. Flicker comparison usually took 1 minute per pair of slides. Sensitivity was 90 %, specificity was 65 %. The sensitivity was reasonably high. The moderate specificity was due to some cases showing "change" with the flicker comparison which might have been overlooked by the expert groups. Flicker comparison is an easy, fast and reliable technique to evaluate pairs of consecutive optic disc photographs.

  9. A novel highly sensitive, rapid and safe Rift Valley fever virus neutralization test.

    PubMed

    Wichgers Schreur, Paul J; Paweska, Janusz T; Kant, Jet; Kortekaas, Jeroen

    2017-10-01

    Antibodies specific for Rift Valley fever virus (RVFV) can be detected by diverse methods, including ezyme-linked immunosortbent assay (ELISA) and virus neutralization test (VNT). The VNT is superior in sensitivity and specificity and is therefore considered the gold standard serological assay. Classical VNTs make use of virulent RVFV and therefore have to be performed in biosafety level 3 laboratories. Here, we report the development of a novel VNT that is based on an avirulent RVFV expressing the enhanced green fluorescent protein (eGFP), which can be performed safely outside level 3 biocontainment facilities. Evaluation with a broad panel of experimental sera and field sera demonstrated that this novel VNT is faster and more sensitive than the classical VNT. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. NEMA NU 4-2008 comparison of preclinical PET imaging systems.

    PubMed

    Goertzen, Andrew L; Bao, Qinan; Bergeron, Mélanie; Blankemeyer, Eric; Blinder, Stephan; Cañadas, Mario; Chatziioannou, Arion F; Dinelle, Katherine; Elhami, Esmat; Jans, Hans-Sonke; Lage, Eduardo; Lecomte, Roger; Sossi, Vesna; Surti, Suleman; Tai, Yuan-Chuan; Vaquero, Juan José; Vicente, Esther; Williams, Darin A; Laforest, Richard

    2012-08-01

    The National Electrical Manufacturers Association (NEMA) standard NU 4-2008 for performance measurements of small-animal tomographs was recently published. Before this standard, there were no standard testing procedures for preclinical PET systems, and manufacturers could not provide clear specifications similar to those available for clinical systems under NEMA NU 2-1994 and 2-2001. Consequently, performance evaluation papers used methods that were modified ad hoc from the clinical PET NEMA standard, thus making comparisons between systems difficult. We acquired NEMA NU 4-2008 performance data for a collection of commercial animal PET systems manufactured since 2000: microPET P4, microPET R4, microPET Focus 120, microPET Focus 220, Inveon, ClearPET, Mosaic HP, Argus (formerly eXplore Vista), VrPET, LabPET 8, and LabPET 12. The data included spatial resolution, counting-rate performance, scatter fraction, sensitivity, and image quality and were acquired using settings for routine PET. The data showed a steady improvement in system performance for newer systems as compared with first-generation systems, with notable improvements in spatial resolution and sensitivity. Variation in system design makes direct comparisons between systems from different vendors difficult. When considering the results from NEMA testing, one must also consider the suitability of the PET system for the specific imaging task at hand.

  11. A new method to address verification bias in studies of clinical screening tests: cervical cancer screening assays as an example.

    PubMed

    Xue, Xiaonan; Kim, Mimi Y; Castle, Philip E; Strickler, Howard D

    2014-03-01

    Studies to evaluate clinical screening tests often face the problem that the "gold standard" diagnostic approach is costly and/or invasive. It is therefore common to verify only a subset of negative screening tests using the gold standard method. However, undersampling the screen negatives can lead to substantial overestimation of the sensitivity and underestimation of the specificity of the diagnostic test. Our objective was to develop a simple and accurate statistical method to address this "verification bias." We developed a weighted generalized estimating equation approach to estimate, in a single model, the accuracy (eg, sensitivity/specificity) of multiple assays and simultaneously compare results between assays while addressing verification bias. This approach can be implemented using standard statistical software. Simulations were conducted to assess the proposed method. An example is provided using a cervical cancer screening trial that compared the accuracy of human papillomavirus and Pap tests, with histologic data as the gold standard. The proposed approach performed well in estimating and comparing the accuracy of multiple assays in the presence of verification bias. The proposed approach is an easy to apply and accurate method for addressing verification bias in studies of multiple screening methods. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Adaptive smoothing based on Gaussian processes regression increases the sensitivity and specificity of fMRI data.

    PubMed

    Strappini, Francesca; Gilboa, Elad; Pitzalis, Sabrina; Kay, Kendrick; McAvoy, Mark; Nehorai, Arye; Snyder, Abraham Z

    2017-03-01

    Temporal and spatial filtering of fMRI data is often used to improve statistical power. However, conventional methods, such as smoothing with fixed-width Gaussian filters, remove fine-scale structure in the data, necessitating a tradeoff between sensitivity and specificity. Specifically, smoothing may increase sensitivity (reduce noise and increase statistical power) but at the cost loss of specificity in that fine-scale structure in neural activity patterns is lost. Here, we propose an alternative smoothing method based on Gaussian processes (GP) regression for single subjects fMRI experiments. This method adapts the level of smoothing on a voxel by voxel basis according to the characteristics of the local neural activity patterns. GP-based fMRI analysis has been heretofore impractical owing to computational demands. Here, we demonstrate a new implementation of GP that makes it possible to handle the massive data dimensionality of the typical fMRI experiment. We demonstrate how GP can be used as a drop-in replacement to conventional preprocessing steps for temporal and spatial smoothing in a standard fMRI pipeline. We present simulated and experimental results that show the increased sensitivity and specificity compared to conventional smoothing strategies. Hum Brain Mapp 38:1438-1459, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  13. Post-Servicing Mission 4 Flux Calibration of the STIS Echelle Modes

    NASA Astrophysics Data System (ADS)

    Azalee Bostroem, K.; Aloisi, A.; Proffitt, C.; Osten, R.; Bohlin, R.

    2011-01-01

    STIS echelle modes show a wavelength-dependent decline in sensitivity with time. While this trend is observed in all STIS spectroscopic modes, the echelle sensitivity is further affected by a time-dependent shift in the blaze function. To improve the echelle flux calibration, new baselines for the echelle sensitivities are derived from post-Servicing Mission 4 (SM4) observations of the Hubble Space Telescope standard star G191-B2B. We present how these baseline sensitivities compare to pre-failure trends. Specifically, where the new results differ from expectations and discuss anomalous results found in E140H monitoring observations are highlighted.

  14. Sensitivity, accuracy, and precision issues in opto-electronic holography based on fiber optics and high-spatial- and high-digitial-resolution cameras

    NASA Astrophysics Data System (ADS)

    Furlong, Cosme; Yokum, Jeffrey S.; Pryputniewicz, Ryszard J.

    2002-06-01

    Sensitivity, accuracy, and precision characteristics in quantitative optical metrology techniques, and specifically in optoelectronic holography based on fiber optics and high-spatial and high-digital resolution cameras, are discussed in this paper. It is shown that sensitivity, accuracy, and precision dependent on both, the effective determination of optical phase and the effective characterization of the illumination-observation conditions. Sensitivity, accuracy, and precision are investigated with the aid of National Institute of Standards and Technology (NIST) traceable gages, demonstrating the applicability of quantitative optical metrology techniques to satisfy constantly increasing needs for the study and development of emerging technologies.

  15. Rapid Molecular Microbiologic Diagnosis of Prosthetic Joint Infection

    PubMed Central

    Cazanave, Charles; Greenwood-Quaintance, Kerryl E.; Hanssen, Arlen D.; Karau, Melissa J.; Schmidt, Suzannah M.; Gomez Urena, Eric O.; Mandrekar, Jayawant N.; Osmon, Douglas R.; Lough, Lindsay E.; Pritt, Bobbi S.; Steckelberg, James M.

    2013-01-01

    We previously showed that culture of samples obtained by prosthesis vortexing and sonication was more sensitive than tissue culture for prosthetic joint infection (PJI) diagnosis. Despite improved sensitivity, culture-negative cases remained; furthermore, culture has a long turnaround time. We designed a genus-/group-specific rapid PCR assay panel targeting PJI bacteria and applied it to samples obtained by vortexing and sonicating explanted hip and knee prostheses, and we compared the results to those with sonicate fluid and periprosthetic tissue culture obtained at revision or resection arthroplasty. We studied 434 subjects with knee (n = 272) or hip (n = 162) prostheses; using a standardized definition, 144 had PJI. Sensitivities of tissue culture, of sonicate fluid culture, and of PCR were 70.1, 72.9, and 77.1%, respectively. Specificities were 97.9, 98.3, and 97.9%, respectively. Sonicate fluid PCR was more sensitive than tissue culture (P = 0.04). PCR of prosthesis sonication samples is more sensitive than tissue culture for the microbiologic diagnosis of prosthetic hip and knee infection and provides same-day PJI diagnosis with definition of microbiology. The high assay specificity suggests that typical PJI bacteria may not cause aseptic implant failure. PMID:23658273

  16. Effectiveness of a Rapid Lumbar Spine MRI Protocol Using 3D T2-Weighted SPACE Imaging Versus a Standard Protocol for Evaluation of Degenerative Changes of the Lumbar Spine.

    PubMed

    Sayah, Anousheh; Jay, Ann K; Toaff, Jacob S; Makariou, Erini V; Berkowitz, Frank

    2016-09-01

    Reducing lumbar spine MRI scanning time while retaining diagnostic accuracy can benefit patients and reduce health care costs. This study compares the effectiveness of a rapid lumbar MRI protocol using 3D T2-weighted sampling perfection with application-optimized contrast with different flip-angle evolutions (SPACE) sequences with a standard MRI protocol for evaluation of lumbar spondylosis. Two hundred fifty consecutive unenhanced lumbar MRI examinations performed at 1.5 T were retrospectively reviewed. Full, rapid, and complete versions of each examination were interpreted for spondylotic changes at each lumbar level, including herniations and neural compromise. The full examination consisted of sagittal T1-weighted, T2-weighted turbo spin-echo (TSE), and STIR sequences; and axial T1- and T2-weighted TSE sequences (time, 18 minutes 40 seconds). The rapid examination consisted of sagittal T1- and T2-weighted SPACE sequences, with axial SPACE reformations (time, 8 minutes 46 seconds). The complete examination consisted of the full examination plus the T2-weighted SPACE sequence. Sensitivities and specificities of the full and rapid examinations were calculated using the complete study as the reference standard. The rapid and full studies had sensitivities of 76.0% and 69.3%, with specificities of 97.2% and 97.9%, respectively, for all degenerative processes. Rapid and full sensitivities were 68.7% and 66.3% for disk herniation, 85.2% and 81.5% for canal compromise, 82.9% and 69.1% for lateral recess compromise, and 76.9% and 69.7% for foraminal compromise, respectively. Isotropic SPACE T2-weighted imaging provides high-quality imaging of lumbar spondylosis, with multiplanar reformatting capability. Our SPACE-based rapid protocol had sensitivities and specificities for herniations and neural compromise comparable to those of the protocol without SPACE. This protocol fits within a 15-minute slot, potentially reducing costs and discomfort for a large subgroup of patients.

  17. Accuracy of real-time PCR, Gram stain and culture for Streptococcus pneumoniae, Neisseria meningitidis and Haemophilus influenzae meningitis diagnosis.

    PubMed

    Wu, Henry M; Cordeiro, Soraia M; Harcourt, Brian H; Carvalho, Mariadaglorias; Azevedo, Jailton; Oliveira, Tainara Q; Leite, Mariela C; Salgado, Katia; Reis, Mitermayer G; Plikaytis, Brian D; Clark, Thomas A; Mayer, Leonard W; Ko, Albert I; Martin, Stacey W; Reis, Joice N

    2013-01-22

    Although cerebrospinal fluid (CSF) culture is the diagnostic reference standard for bacterial meningitis, its sensitivity is limited, particularly when antibiotics were previously administered. CSF Gram staining and real-time PCR are theoretically less affected by antibiotics; however, it is difficult to evaluate these tests with an imperfect reference standard. CSF from patients with suspected meningitis from Salvador, Brazil were tested with culture, Gram stain, and real-time PCR using S. pneumoniae, N. meningitidis, and H. influenzae specific primers and probes. An antibiotic detection disk bioassay was used to test for the presence of antibiotic activity in CSF. The diagnostic accuracy of tests were evaluated using multiple methods, including direct evaluation of Gram stain and real-time PCR against CSF culture, evaluation of real-time PCR against a composite reference standard, and latent class analysis modeling to evaluate all three tests simultaneously. Among 451 CSF specimens, 80 (17.7%) had culture isolation of one of the three pathogens (40 S. pneumoniae, 36 N. meningitidis, and 4 H. influenzae), and 113 (25.1%) were real-time PCR positive (51 S. pneumoniae, 57 N. meningitidis, and 5 H. influenzae). Compared to culture, real-time PCR sensitivity and specificity were 95.0% and 90.0%, respectively. In a latent class analysis model, the sensitivity and specificity estimates were: culture, 81.3% and 99.7%; Gram stain, 98.2% and 98.7%; and real-time PCR, 95.7% and 94.3%, respectively. Gram stain and real-time PCR sensitivity did not change significantly when there was antibiotic activity in the CSF. Real-time PCR and Gram stain were highly accurate in diagnosing meningitis caused by S. pneumoniae, N. meningitidis, and H. influenzae, though there were few cases of H. influenzae. Furthermore, real-time PCR and Gram staining were less affected by antibiotic presence and might be useful when antibiotics were previously administered. Gram staining, which is inexpensive and commonly available, should be encouraged in all clinical settings.

  18. Accuracy of cystatin C for the detection of abnormal renal function in children undergoing chemotherapy for malignancy: a systematic review using individual patient data.

    PubMed

    Whiting, Penny; Birnie, Kate; Sterne, Jonathan A C; Jameson, Catherine; Skinner, Rod; Phillips, Bob

    2018-05-01

    We conducted a systematic review and individual patient data (IPD) meta-analysis to examine the utility of cystatin C for evaluation of glomerular function in children with cancer. Eligible studies evaluated the accuracy of cystatin C for detecting poor renal function in children undergoing chemotherapy. Study quality was assessed using QUADAS-2. Authors of four studies shared IPD. We calculated the correlation between log cystatin C and GFR stratified by study and measure of cystatin C. We dichotomized the reference standard at GFR 80 ml/min/1.73m 2 and stratified cystatin C at 1 mg/l, to calculate sensitivity and specificity in each study and according to age group (0-4, 5-12, and ≥ 13 years). In sensitivity analyses, we investigated different GFR and cystatin C cut points. We used logistic regression to estimate the association of impaired renal function with log cystatin C and quantified diagnostic accuracy using the area under the ROC curve (AUC). Six studies, which used different test and reference standard thresholds, suggested that cystatin C has the potential to monitor renal function in children undergoing chemotherapy for malignancy. IPD data (504 samples, 209 children) showed that cystatin C has poor sensitivity (63%) and moderate specificity (89%), although use of a GFR cut point of < 60 ml/min/1.73m 2 (data only available from two of the studies) estimated sensitivity to be 92% and specificity 81.3%. The AUC for the combined data set was 0.890 (95% CI 0.826, 0.951). Diagnostic accuracy appeared to decrease with age. Cystatin C has better diagnostic accuracy than creatinine as a test for glomerular dysfunction in young people undergoing treatment for cancer. Diagnostic accuracy is not sufficient for it to replace current reference standards for predicting clinically relevant impairments that may alter dosing of important nephrotoxic agents.

  19. An accuracy evaluation of clinical, arthrometric, and stress-sonographic acute ankle instability examinations.

    PubMed

    Wiebking, Ulrich; Pacha, Tarek Omar; Jagodzinski, Michael

    2015-03-01

    Ankle sprain injuries, often due to lateral ligamentous injury, are the most common sports traumatology conditions. Correct diagnoses require an understanding of the assessment tools with a high degree of diagnostic accuracy. Obviously, there are still no clear consensuses or standard methods to differentiate between a ligament tear and an ankle sprain. In addition to clinical assessments, stress sonography, arthrometer and other methods are often performed simultaneously. These methods are often costly, however, and their accuracy is controversial. The aim of this study was to investigate three different measurement tools that can be used after a lateral ligament lesion of the ankle with injury of the anterior talofibular ligament to determine their diagnostic accuracy. Thirty patients were recruited for this study. The mean patient age was 35±14 years. There were 15 patients with a ligamentous rupture and 15 patients with an ankle sprain. We quantified two devices and one clinical assessment by which we calculated the sensitivity and specifity: Stress sonography according to Hoffmann, an arthrometer to investigate the 100N talar drawer and maximum manual testing and the clinical assessment of the anterior drawer test. A high resolution sonography was used as the gold standard. The ultrasound-assisted gadgetry according to Hoffmann, with a 3mm cut-off value, displayed a sensitivity of 0.27 and a specificity of 0.87. Using a 3.95mm cut-off value, the arthrometer displayed a sensitivity of 0.8 and a specificity of 0.4. The clinical investigation sensitivities and specificities were 0.93 and 0.67, respectively. Different assessment methods for ankle rupture diagnoses are suggested in the literature; however, these methods lack reliable data to set investigation standards. Clinical examination under adequate analgesia seems to remains the most reliable tool to investigate ligamentous ankle lesions. Further clinical studies with higher case numbers are necessary, however, to evaluate these findings and to measure the reliability. Copyright © 2014 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  20. Sensitivity and specificity of western blot testing of cerebrospinal fluid and serum for diagnosis of equine protozoal myeloencephalitis in horses with and without neurologic abnormalities.

    PubMed

    Daft, Barbara M; Barr, Bradd C; Gardner, Ian A; Read, Deryck; Bell, William; Peyser, Karen G; Ardans, Alex; Kinde, Hailu; Morrow, Jennifer K

    2002-10-01

    To determine sensitivity and specificity of western blot testing (WBT) of CSF and serum for diagnosis of equine protozoal myeloencephalitis (EPM) in horses with and without neurologic abnormalities. Prospective investigation. 65 horses with and 169 horses without neurologic abnormalities. CSF and serum from horses submitted for necropsy were tested for Sarcocystis neurona-specific antibody with a WBT. Results of postmortem examination were used as the gold standard against which results of the WBT were compared. Sensitivity of WBT of CSF was 87% for horses with and 88% for horses without neurologic abnormalities. Specificity of WBT of CSF was 44% for horses with and 60% for horses without neurologic abnormalities. Regardless of whether horses did or did not have neurologic abnormalities, sensitivity and specificity of WBT of serum were not significantly different from values for WBT of CSF. Ninety-four horses without EPM had histologic evidence of slight CNS inflammation. The low specificity of WBT of CSF indicated that it is inappropriate to diagnose EPM on the basis of a positive test result alone because of the possibility of false-positive test results. The high sensitivity, however, means that a negative result is useful in ruling out EPM. There was no advantage in testing CSF versus serum in horses without neurologic abnormalities. Slight CNS inflammation was common in horses with and without S neurona-specific antibodies in the CSF and should not be considered an indication of CNS infection with S neurona.

  1. PCR/LDR/universal array platforms for the diagnosis of infectious disease.

    PubMed

    Pingle, Maneesh; Rundell, Mark; Das, Sanchita; Golightly, Linnie M; Barany, Francis

    2010-01-01

    Infectious diseases account for between 14 and 17 million deaths worldwide each year. Accurate and rapid diagnosis of bacterial, fungal, viral, and parasitic infections is therefore essential to reduce the morbidity and mortality associated with these diseases. Classical microbiological and serological methods have long served as the gold standard for diagnosis but are increasingly being replaced by molecular diagnostic methods that demonstrate increased sensitivity and specificity and provide an identification of the etiologic agent in a shorter period of time. PCR/LDR coupled with universal array detection provides a highly sensitive and specific platform for the detection and identification of bacterial and viral infections.

  2. PCR/LDR/Universal Array Platforms for the Diagnosis of Infectious Disease

    PubMed Central

    Pingle, Maneesh; Rundell, Mark; Das, Sanchita; Golightly, Linnie M.; Barany, Francis

    2015-01-01

    Infectious diseases account for between 14 and 17 million deaths worldwide each year. Accurate and rapid diagnosis of bacterial, fungal, viral, and parasitic infections is therefore essential to reduce the morbidity and mortality associated with these diseases. Classical microbiological and serological methods have long served as the gold standard for diagnosis but are increasingly being replaced by molecular diagnostic methods that demonstrate increased sensitivity and specificity and provide an identification of the etiologic agent in a shorter period of time. PCR/LDR coupled with universal array detection provides a highly sensitive and specific platform for the detection and identification of bacterial and viral infections. PMID:20217576

  3. The Role of PCR in the Diagnosis of Candida Vulvovaginitis-a New Gold Standard?

    PubMed

    Sobel, J D; Akins, Robert A

    2015-06-01

    PCR is recognized as a reliable technique for detection of all types of microorganisms. Being highly objective and reproducible also sensitive and specific, PCR is now widely used for sexually transmitted infection (STI) diagnosis. Potential, however, exists for detecting non-pathogens, and not identifying a pathogenic state decreases specificity or clinical significance. PCR Candida tests of vaginal specimens are now widely available and frequently used offering a modest to moderate increase in sensitivity and are likely to replace traditional culture and DNA homology testing. Nevertheless, there remain considerable gaps in our knowledge regarding the usefulness and applications of these expensive tests.

  4. Acute Sport-Related Concussion Screening for Collegiate Athletes Using an Instrumented Balance Assessment.

    PubMed

    Baracks, Joshua; Casa, Douglas J; Covassin, Tracey; Sacko, Ryan; Scarneo, Samantha E; Schnyer, David; Yeargin, Susan W; Neville, Christopher

    2018-06-13

      Without a true criterion standard assessment, the sport-related concussion (SRC) diagnosis remains subjective. Inertial balance sensors have been proposed to improve acute SRC assessment, but few researchers have studied their clinical utility.   To determine if group differences exist when using objective measures of balance in a sample of collegiate athletes with recent SRCs and participants serving as the control group and to calculate sensitivity and specificity to determine the diagnostic utility of the inertial balance sensor for acute SRC injuries.   Cohort study.   Multicenter clinical trial.   We enrolled 48 participants with SRC (age = 20.62 ± 1.52 years, height = 179.76 ± 10.00 cm, mass = 83.92 ± 23.22 kg) and 45 control participants (age = 20.85 ± 1.42 years, height = 177.02 ± 9.59 cm, mass = 74.61 ± 14.92 kg) at 7 clinical sites in the United States. All were varsity or club collegiate athletes, and all participants with SRC were tested within 72 hours of SRC.   Balance performance was assessed using an inertial balance sensor. Two measures (root mean square [RMS] sway and 95% ellipse sway area) were analyzed to represent a range of general balance measures. Balance assessments were conducted in double-legged, single-legged, and tandem stances.   A main effect for group was associated with the root mean square sway measure ( F 1,91 = 11.75, P = .001), with the SRC group demonstrating balance deficits compared with the control group. We observed group differences in the 95% ellipse sway area measure for the double-legged ( F 1,91 = 11.59, P = .001), single-legged ( F 1,91 = 6.91, P = .01), and tandem ( F 1,91 = 7.54, P = .007) stances. Sensitivity was greatest using a cutoff value of 0.5 standard deviations (54% [specificity = 71%]), whereas specificity was greatest using a cutoff value of 2 standard deviations (98% [sensitivity = 33%]).   Inertial balance sensors may be useful tools for objectively measuring balance during acute SRC evaluation. However, low sensitivity suggests that they may be best used in conjunction with other assessments to form a comprehensive screening that may improve sensitivity.

  5. Improved sensitivity and specificity for resting state and task fMRI with multiband multi-echo EPI compared to multi-echo EPI at 7 T.

    PubMed

    Boyacioğlu, Rasim; Schulz, Jenni; Koopmans, Peter J; Barth, Markus; Norris, David G

    2015-10-01

    A multiband multi-echo (MBME) sequence is implemented and compared to a matched standard multi-echo (ME) protocol to investigate the potential improvement in sensitivity and spatial specificity at 7 T for resting state and task fMRI. ME acquisition is attractive because BOLD sensitivity is less affected by variation in T2*, and because of the potential for separating BOLD and non-BOLD signal components. MBME further reduces TR thus increasing the potential reduction in physiological noise. In this study we used FSL-FIX to clean ME and MBME resting state and task fMRI data (both 3.5mm isotropic). After noise correction, the detection of resting state networks improves with more non-artifactual independent components being observed. Additional activation clusters for task data are discovered for MBME data (increased sensitivity) whereas existing clusters become more localized for resting state (improved spatial specificity). The results obtained indicate that MBME is superior to ME at high field strengths. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Development of Electrochemiluminescent Serology Assays to Measure the Humoral Response to Antigens of Respiratory Syncytial Virus.

    PubMed

    Maifeld, Sarah V; Ro, Bodrey; Mok, Hoyin; Chu, Marla; Yu, Li; Yamagata, Ryan; Leonardson, Tansy; Chio, Vera; Parhy, Bandita; Park, Samuel; Carlson, Marcia; Machhi, Shushil; Ulbrandt, Nancy; Falsey, Ann R; Walsh, Edward E; Wang, C Kathy; Esser, Mark T; Zuo, Fengrong

    2016-01-01

    Sensitive and precise serology assays are needed to measure the humoral response to antigens of respiratory syncytial virus (RSV) following natural infection or vaccination. We developed and evaluated a collection of electrochemiluminescent (ECL) serology assays using four RSV antigens (F, N, Ga and Gb). To assess the merits of ECL technology, the four ECL serology assays were evaluated using a well-characterized "gold standard" panel of acute and convalescent serum samples from fifty-nine RSV-positive and thirty RSV-negative elderly subjects (≥65 years old). The combined results from the four ECL assays demonstrated good concordance to the "gold standard" diagnosis, reaching 95% diagnostic sensitivity and 100% diagnostic specificity. Additionally, a combination of ECL assays provided higher diagnostic sensitivity than a commercially available diagnostic ELISA or cell-based microneutralization assay. In summary, these data demonstrate the advantages of using ECL-based serology assays and highlight their use as a sensitive diagnostic approach to detect recent RSV infection in an elderly population.

  7. [Application value of Xpert MTB/RIF in diagnosis of spinal tuberculosis and detection of rifampin resistance].

    PubMed

    Jin, Yang-Hui; Shi, Shi-Yuan; Zheng, Qi; Shen, Jian; Ying, Xiao-Zhang; Wang, Yi-Fan

    2017-09-25

    To investigate the application value of Xpert MTB/RIF in diagnosis of spinal tuberculosis and detection of rifampin resistance. The 109 pus specimens were obtained from patients who were primaryly diagnosed as spinal tuberculosis. All of the pus specimens were detected by acid-fast stain, liquid fast culturing by BACTEC MGIT 960 and Xpert MTB/RIF assay to definite the differences in sensitivity and specificity of mycobacterium tuberculosis among detecting methods. Pus specimens obtained by different methods were deteceded by MTB/RIF test to analyze the self-influence on Xpert MTB/RIF test. The result of liquid fast culturing by BACTEC MGIT 960 was used as the gold standard; and the value of Xpert MTB/RIF assay in detecting rifampin resistance was analyzed. The sensitivity of acid-fast stain, liquid fast culturing by BACTEC MGIT 960 and Xpert MTB/RIF assay were 25.92%, 48.15%, 77.78%, respectively. The sensitivity of pus specimens obtained from open surgery, ultrasound positioning puncture and biopsy the sensitivity were 83.78%, 76.47%, 44.68% respectively deteceded by MTB/RIF test. According to the gold standard of the results of liquid fast culturing by BACTEC MGIT 960 assay, the sensitivity and specificity of Xpert MTB/RIF assay in detecting rifampin resistance were 80%(4/5) and 90.70%(39/43), respectively. Xpert MTB/RIF assay has higher value in diagnosis of spinal tuberculosi, and also can detect rifampin resistance. The number of mycobacterium tuberculosis in pus specimens has a great influence in the sensitivity of Xpert MTB/RIF assay.

  8. Do race-specific definitions of short long bones improve the detection of down syndrome on second-trimester genetic sonograms?

    PubMed

    Harper, Lorie M; Gray, Diana; Dicke, Jeffrey; Stamilio, David M; Macones, George A; Odibo, Anthony O

    2010-02-01

    The purpose of this study was to determine whether the use of race-specific definitions of short femur and humerus lengths improves Down syndrome detection. This was a retrospective cohort study over 16 years. For each self-reported maternal race (white, African American, Hispanic, and Asian), we evaluated the efficiency of Down syndrome detection using published race-specific formulas compared with a standard formula for short femur and humerus lengths (observed versus expected lengths < or =0.91 and < or =0.89, respectively). The sensitivity, specificity, and 95% confidence intervals for each parameter were compared. Screening performance was compared by areas under the receiver operating characteristic curves. Of 58,710 women, 209 (0.3%) had a diagnosis of a fetus with Down syndrome. Although the race-based formula increased sensitivity in each population, the increase was statistically significant only in the white population, whereas a decrease in specificity was statistically significant in all 4 populations, as denoted by nonoverlapping confidence intervals. The area under the receiver operating characteristic curve for the model using the race-specific definition of short femur length was 0.67 versus 0.65 compared with the standard definition, and for humerus length it was 0.70 versus 0.71. The use of race-based formulas for the determination of short femur and humerus lengths did not significantly improve the detection rates for Down syndrome.

  9. Commercial test kits for detection of Lyme borreliosis: a meta-analysis of test accuracy

    PubMed Central

    Cook, Michael J; Puri, Basant K

    2016-01-01

    The clinical diagnosis of Lyme borreliosis can be supported by various test methodologies; test kits are available from many manufacturers. Literature searches were carried out to identify studies that reported characteristics of the test kits. Of 50 searched studies, 18 were included where the tests were commercially available and samples were proven to be positive using serology testing, evidence of an erythema migrans rash, and/or culture. Additional requirements were a test specificity of ≥85% and publication in the last 20 years. The weighted mean sensitivity for all tests and for all samples was 59.5%. Individual study means varied from 30.6% to 86.2%. Sensitivity for each test technology varied from 62.4% for Western blot kits, and 62.3% for enzyme-linked immunosorbent assay tests, to 53.9% for synthetic C6 peptide ELISA tests and 53.7% when the two-tier methodology was used. Test sensitivity increased as dissemination of the pathogen affected different organs; however, the absence of data on the time from infection to serological testing and the lack of standard definitions for “early” and “late” disease prevented analysis of test sensitivity versus time of infection. The lack of standardization of the definitions of disease stage and the possibility of retrospective selection bias prevented clear evaluation of test sensitivity by “stage”. The sensitivity for samples classified as acute disease was 35.4%, with a corresponding sensitivity of 64.5% for samples from patients defined as convalescent. Regression analysis demonstrated an improvement of 4% in test sensitivity over the 20-year study period. The studies did not provide data to indicate the sensitivity of tests used in a clinical setting since the effect of recent use of antibiotics or steroids or other factors affecting antibody response was not factored in. The tests were developed for only specific Borrelia species; sensitivities for other species could not be calculated. PMID:27920571

  10. [Value of desmopressin stimulation test and high dose dexamethasone suppression testin the etiologic diagnosis of ACTH dependent Cushing's syndrome].

    PubMed

    Zhang, Weiwei; Yu, Yerong; Tan, Huiwen; Wang, Chun; Li, Jianwei; An, Zhenmei; Liu, Yuping

    2016-03-22

    To investigate the value of desmopressin (DDAVP) stimulation test and high dose dexamethasone suppression test (HDDST) in establishing the cause of ACTH dependent Cushing's syndrome. The clinical data of patients with ACTH dependent Cushing's syndrome at West China Hospital from January 1, 2010 to September 30, 2015 was analyzed. The sensitivity and specificity of DDAVP stimulation test, HDDST, and the diagnostic accordance rate when the two tests were combined, were evaluated based on the diagnostic gold standard. A total of 85 patients with Cushing's disease and 10 patients with ectopic ACTH syndrome were included. The sensitivity and specificity of DDAVP stimulation test were 87% and 5/5, respectively, whereas those of HDDST were 79% and 8/10, respectively. The standard high dose dexamethasone suppression test showed a higher sensitivity than overnight 8 mg dexamethasone suppression test. When the two tests had consistent results, the diagnostic accordance rate was 100%. DDAVP stimulation test and HDDST are both efficient modalities for the diagnosis of Cushing's Disease and ectopic ACTH syndrome. The accuracy of diagnosis can be further improved by combining the two tests.

  11. Evaluating of small intracranial aneurysms by 64-detector CT Angiography: a comparison with 3-dimensional rotation DSA or surgical findings.

    PubMed

    Zhang, He; Hou, Chang; Zhou, Zhi; Zhang, Hao; Zhou, Gen; Zhang, Gui

    2014-01-01

    The diagnostic performance of 64-detector computed tomographic angiography (CTA) for detection of small intracranial aneurysms (SIAs) was evaluated. In this prospective study, 112 consecutive patients underwent 64-detector CTA before volume-rendering rotation digital subtraction angiography (VR-RDSA) or surgery. VR-RDSA or intraoperative findings or both were used as the gold standards. The accuracy, sensitivity, specificity, and positive predictive values (PPV) and negative predictive values (NPV), as measures to detect or rule out SIAs, were determined by patient-based and aneurysm size-based evaluations. The reference standard methods revealed 84 small aneurysms in 71 patients. The results of patient-based 64-detector CTA evaluation for SIAs were: accuracy, 98.2%; sensitivity, 98.6%; specificity, 97.6%; PPV, 98.6%; and NPV, 97.6%. The aneurysm-based evaluation results were: accuracy, 96.8%; sensitivity, 97.6%; specificity, 95.1%; PPV, 97.6%; and NPV, 95.1%. Two false-positive and two false-negative findings for aneurysms <3 mm in size occurred in the 64-detector CTA analysis. The diagnostic performance of 64-detector CTA did not improve much compared with 16-detector CTA for detecting SIAs, especially for very small aneurysms. VR-RDSA is still necessary for patients with a history of subarachnoid hemorrhage if the CTA findings are negative. Copyright © 2012 by the American Society of Neuroimaging.

  12. Rapid screening for inflammatory neuropathies by standardized clinical criteria

    PubMed Central

    Tramontozzi, Louis A.

    2016-01-01

    Abstract Background: Delay in recognition and treatment of inflammatory neuropathies increases morbidity and mortality. We have developed and standardized 3 clinical screening criteria that rapidly detect inflammatory neuropathies. Methods: We reviewed all patients with definite large fiber neuropathy in 2 different patient populations: 1 from a private neurology clinic and the other from a tertiary care center. Patients were divided into 2 groups: those with an inflammatory neuropathy and those with a noninflammatory neuropathy. We specifically noted the 3 key neuropathy characteristics: onset, distribution, and associated systemic features (ODS). We studied the sensitivity and specificity of ODS in differentiating between inflammatory and noninflammatory neuropathies. Results: A total of 206 patients were included: 51 from the private clinic and 155 from the tertiary care center. The sensitivity of using ODS in detecting an inflammatory neuropathy was 96% and the specificity was 85%. The positive predictive value of ODS was 0.8 and negative predictive value was 0.97. Conclusions: Rapid screening for inflammatory neuropathies by ODS clinical criteria is highly sensitive and has a high negative predictive value for noninflammatory neuropathies. ODS uses simple clinical criteria to rapidly screen for patients with a potentially treatable form of neuropathy and accelerate their diagnostic evaluation. Classification of evidence: This study provides Class IV evidence that 3 neuropathy characteristics—onset, distribution, and associated systemic features—accurately identify patients with inflammatory neuropathies. PMID:29443273

  13. The role of Xpert MTB/RIF assay in the diagnosis of tubercular spondylodiscitis.

    PubMed

    Arockiaraj, Justin; Michael, Joy S; Amritanand, Rohit; David, Kenny Samuel; Krishnan, Venkatesh

    2017-12-01

    This study aims to assess the accuracy of the Xpert MTB/RIF assay in the diagnosis of tubercular spondylodiscitis and to identify its role in detecting Rifampicin resistance in patients with infective spondylodiscitis. A retrospective study including 348 patients suspected to have infective spondylodiscitis was done. Tissue/pus samples obtained were sent for culture, histopathology and Xpert MTB/RIF assay. All patients who were confirmed to have tubercular spondylodiscitis and those patients who were suspected on clinico-radiological basis were also treated with anti-tuberculous chemotherapy for a period of 9 months. The efficacy of the Xpert MTB/RIF assay was assessed in terms of sensitivity and specificity when compared to culture, histopathology, and Composite reference standard (CRS). During this study period of 24 months, a total of 348 patients were treated for infective spondylodiscitis. 254 patients were treated for tuberculosis following a smear positivity, culture positivity, and histopathology report or empirically based on clinico-radiological findings. The sensitivity and specificity of the Xpert MTB/RIF assay when compared to culture were 88.4 and 63.7%, respectively. When compared to both culture and histopathology reports it was 80.9 and 80.6%. The sensitivity and specificity of the Xpert MTB/RIF assay when compared to composite reference standard were 71.2 and 100%, respectively. The sensitivity of the assay to detect Rifampicin resistance was 100%. The prevalence of Rifampicin resistance was 5.1%. This study recommends Xpert MTB/RIF assay for early detection of Mycobacterium tubercular spondylodiscitis and Rifampicin resistance.

  14. Electronic monitoring of treatment adherence and validation of alternative adherence measures in tuberculosis patients: a pilot study.

    PubMed

    van den Boogaard, Jossy; Lyimo, Ramsey A; Boeree, Martin J; Kibiki, Gibson S; Aarnoutse, Rob E

    2011-09-01

    To assess adherence to community-based directly observed treatment (DOT) among Tanzanian tuberculosis patients using the Medication Event Monitoring System (MEMS) and to validate alternative adherence measures for resource-limited settings using MEMS as a gold standard. This was a longitudinal pilot study of 50 patients recruited consecutively from one rural hospital, one urban hospital and two urban health centres. Treatment adherence was monitored with MEMS and the validity of the following adherence measures was assessed: isoniazid urine test, urine colour test, Morisky scale, Brief Medication Questionnaire, adapted AIDS Clinical Trials Group (ACTG) adherence questionnaire, pill counts and medication refill visits. The mean adherence rate in the study population was 96.3% (standard deviation, SD: 7.7). Adherence was less than 100% in 70% of the patients, less than 95% in 21% of them, and less than 80% in 2%. The ACTG adherence questionnaire and urine colour test had the highest sensitivities but lowest specificities. The Morisky scale and refill visits had the highest specificities but lowest sensitivities. Pill counts and refill visits combined, used in routine practice, yielded moderate sensitivity and specificity, but sensitivity improved when the ACTG adherence questionnaire was added. Patients on community-based DOT showed good adherence in this study. The combination of pill counts, refill visits and the ACTG adherence questionnaire could be used to monitor adherence in settings where MEMS is not affordable. The findings with regard to adherence and to the validity of simple adherence measures should be confirmed in larger populations with wider variability in adherence rates.

  15. Diagnostic performance of CareStart™ malaria HRP2/pLDH (Pf/pan) combo test versus standard microscopy on falciparum and vivax malaria between China-Myanmar endemic borders

    PubMed Central

    2013-01-01

    Background Rapid diagnostic test (RDT) is becoming an alternative way of establishing quickly the diagnosis of malaria infections, by detecting specific malaria antigens in suspected patients’ blood between the China-Myanmar endemic borders areas, towards achieving the National Malaria Elimination programme by 2020. The objective of this study is to evaluate the performance of CareStart™ Malaria Pf/Pan RDT kit for the diagnosis of malaria infections in suspected patients. Blood examination by microscopy was taken as gold standard to evaluate CareStart™ kit’s sensitivity, specificity and predictive value and corrected with PCR assay. Results Overall 126 of 241 (52.28%) malaria cases were detected by microscopy compared to 115 of 241(47.72%) CareStart™ kit and 128 of 241 (53.11%) PCR corrected assay. CareStart™ kit’s sensitivity and specificity for the diagnosis of malaria were 89.68% and 98.26% respectively, compared to standard microscopy, whereas the sensitivity and specificity for falciparum malaria were 88.52% and 98.26%, and for vivax malaria: 90.77% and 100%. The CareStart™ positive predictive values were 98.26% (93.88-99.52%, 95% CI) compared to 100% (96.77-100%, 95% CI) for PCR-corrected, and the negative predictive values of 89.68% (83.15-93.87%, 95% CI) were the same in microscopy as PCR-corrected. The diagnostic accuracy of CareStart™ kit versus microscopy and PCR were 93.78% (89.99-96.19%, 95% CI) and 94.61% (90.99-96.82%, 95% CI) respectively. The likelihood of diagnostic of malaria positive was almost similar between microscopy and CareStart™ kit, with an entropy reduction of 60.0% compared to a weak likelihood of misdiagnosis of 0.10 (0.09-0.12, 95% CI), with an entropy reduction of 36.01%. Conclusion The accuracy of CareStart™ kit is comparable to gold standard microscopy in these areas, it is easy to perform and suitable for cross-border diagnosis and monitoring of local or imported malaria patterns by any local health staff in endemic remotes. PMID:23294729

  16. Diagnostic performance of CareStart™ malaria HRP2/pLDH (Pf/pan) combo test versus standard microscopy on falciparum and vivax malaria between China-Myanmar endemic borders.

    PubMed

    Xiaodong, Sun; Tambo, Ernest; Chun, Wei; Zhibin, Cheng; Yan, Deng; Jian, Wang; Jiazhi, Wang; Xiaonong, Zhou

    2013-01-07

    Rapid diagnostic test (RDT) is becoming an alternative way of establishing quickly the diagnosis of malaria infections, by detecting specific malaria antigens in suspected patients' blood between the China-Myanmar endemic borders areas, towards achieving the National Malaria Elimination programme by 2020. The objective of this study is to evaluate the performance of CareStart™ Malaria Pf/Pan RDT kit for the diagnosis of malaria infections in suspected patients. Blood examination by microscopy was taken as gold standard to evaluate CareStart™ kit's sensitivity, specificity and predictive value and corrected with PCR assay. Overall 126 of 241 (52.28%) malaria cases were detected by microscopy compared to 115 of 241(47.72%) CareStart™ kit and 128 of 241 (53.11%) PCR corrected assay. CareStart™ kit's sensitivity and specificity for the diagnosis of malaria were 89.68% and 98.26% respectively, compared to standard microscopy, whereas the sensitivity and specificity for falciparum malaria were 88.52% and 98.26%, and for vivax malaria: 90.77% and 100%. The CareStart™ positive predictive values were 98.26% (93.88-99.52%, 95% CI) compared to 100% (96.77-100%, 95% CI) for PCR-corrected, and the negative predictive values of 89.68% (83.15-93.87%, 95% CI) were the same in microscopy as PCR-corrected. The diagnostic accuracy of CareStart™ kit versus microscopy and PCR were 93.78% (89.99-96.19%, 95% CI) and 94.61% (90.99-96.82%, 95% CI) respectively. The likelihood of diagnostic of malaria positive was almost similar between microscopy and CareStart™ kit, with an entropy reduction of 60.0% compared to a weak likelihood of misdiagnosis of 0.10 (0.09-0.12, 95% CI), with an entropy reduction of 36.01%. The accuracy of CareStart™ kit is comparable to gold standard microscopy in these areas, it is easy to perform and suitable for cross-border diagnosis and monitoring of local or imported malaria patterns by any local health staff in endemic remotes.

  17. [An exploratory study on the diagnostic cutoff value of International HIV-associated Dementia Scale in minority ethnic groups with different educational levels, in Guangxi].

    PubMed

    Zhao, Ting-ting; Feng, Qi-ming; Liang, Hao; Tang, Xian-yan; Wei, Bo

    2011-11-01

    Using Intelligence Scale of Mini Mental State Estimated (MMSE) as the gold standard to determine the relevance of International HIV-associated Dementia Scale (IHDS) in minority ethnic areas in Guangxi populations with different cultural values. Corresponding boundary value related to the authenticity and reliability on IHDS were also evaluated. 200 patients with HIV infection were randomly selected from the minority ethnic groups in Guangxi. For each infected person, MMSE and IHDS blind scale were tested at the same period. Using the results from MMSE scale test as the gold standard, ROC curve and IHDS scale in Guangxi minority populations with different education levels which related to the diagnosis of dementia-HIV values were determined. The value of a specific sector under the IHDS sensitivity, specificity, and internal consistency coefficients was also evaluated. When considering the infected person did not differ on their educational level, the IHDS scale diagnostic cutoff appeared as 8.25, while IHDS sensitivity as 0.925, specificity as 0.731 and Kappa as 0.477 (P < 0.001). When considering the extent of cultural differences did influence the prevalence of infection, the different education groups showed different IHDS diagnostic cutoff values. People with high school, secondary school or higher education levels, the IHDS diagnosis appeared to be 8.25, when sensitivity was 0.917, specificity was 0.895 and Kappa was 0.722 (P < 0.001). People with only primary education level, the IHDS appeared to be 7.25. When sensitivity was 0.875, specificity was 0.661 and Kappa was 0.372 (P < 0.001). The IHDS diagnostic sector in Guangxi minority groups was lower than the internationally recommended level of diagnostic cutoff value (IHDS ≤ 10 points). When using IHDS to perform the HIV related dementia screening program, in the minority areas of Guangxi, culture context, the degree and difference of HIV infection should be considered, especially in using IHDS diagnostic cutoff values.

  18. Peptide fingerprinting of Alzheimer's disease in cerebrospinal fluid: identification and prospective evaluation of new synaptic biomarkers.

    PubMed

    Jahn, Holger; Wittke, Stefan; Zürbig, Petra; Raedler, Thomas J; Arlt, Sönke; Kellmann, Markus; Mullen, William; Eichenlaub, Martin; Mischak, Harald; Wiedemann, Klaus

    2011-01-01

    Today, dementias are diagnosed late in the course of disease. Future treatments have to start earlier in the disease process to avoid disability requiring new diagnostic tools. The objective of this study is to develop a new method for the differential diagnosis and identification of new biomarkers of Alzheimer's disease (AD) using capillary-electrophoresis coupled to mass-spectrometry (CE-MS) and to assess the potential of early diagnosis of AD. Cerebrospinal fluid (CSF) of 159 out-patients of a memory-clinic at a University Hospital suffering from neurodegenerative disorders and 17 cognitively-healthy controls was used to create differential peptide pattern for dementias and prospective blinded-comparison of sensitivity and specificity for AD diagnosis against the Criterion standard in a naturalistic prospective sample of patients. Sensitivity and specificity of the new method compared to standard diagnostic procedures and identification of new putative biomarkers for AD was the main outcome measure. CE-MS was used to reliably detect 1104 low-molecular-weight peptides in CSF. Training-sets of patients with clinically secured sporadic Alzheimer's disease, frontotemporal dementia, and cognitively healthy controls allowed establishing discriminative biomarker pattern for diagnosis of AD. This pattern was already detectable in patients with mild cognitive impairment (MCI). The AD-pattern was tested in a prospective sample of patients (n = 100) and AD was diagnosed with a sensitivity of 87% and a specificity of 83%. Using CSF measurements of beta-amyloid1-42, total-tau, and phospho(181)-tau, AD-diagnosis had a sensitivity of 88% and a specificity of 67% in the same sample. Sequence analysis of the discriminating biomarkers identified fragments of synaptic proteins like proSAAS, apolipoprotein J, neurosecretory protein VGF, phospholemman, and chromogranin A. The method may allow early differential diagnosis of various dementias using specific peptide fingerprints and identification of incipient AD in patients suffering from MCI. Identified biomarkers facilitate face validity for the use in AD diagnosis.

  19. Computed tomography for occult fractures of the proximal femur, pelvis, and sacrum in clinical practice: single institution, dual-site experience.

    PubMed

    Mandell, Jacob C; Weaver, Michael J; Khurana, Bharti

    2018-06-01

    The purpose of this study was to evaluate the diagnostic performance of CT for assessment of occult fractures of the proximal femur, pelvis, and sacrum. A retrospective review was performed on patients who received a CT of the hip or pelvis for suspected occult fracture after negative or equivocal radiographs performed within 24 h. The official radiology report was utilized for the determination of CT findings and calculation of sensitivity and specificity. Surgical reports, MRI reports, and clinical follow-up were used as the standard of reference. Sensitivity and specificity were calculated with 95% confidence intervals. Seventy-four patients received CT of the hip or pelvis for clinical concern for occult fracture after negative or equivocal radiographs. By the reference standard, a total of 40 fractures were present in 25/74 (33.8%) patients, including 35 conservatively treated fractures of the greater trochanter, pelvis, and sacrum, and 5 operatively treated proximal femoral fractures. A total of 14/74 (18.9%) of patients had an MRI within 1 day of CT. MRI identified an operatively treated femoral neck fracture not seen on CT and an operatively treated intertrochanteric fracture, which CT described as a greater trochanteric fracture. There were two false negative conservatively treated pelvic fractures not seen on CT but diagnosed on MRI. On a per-patient basis, CT had an overall sensitivity of 88% (22/25; 95% confidence intervals 69-97%), specificity of 98% (48/49; 95% confidence intervals 89-100%), and negative predictive value of 94%. For the five operative proximal femoral fractures, the sensitivity of CT was 60% (3/5; 95% confidence intervals 15-95%), specificity was 99% (68/69; 95% confidence intervals 92-100%), and negative predictive value was 97%. In the clinical setting of suspected occult fracture, the sensitivity of clinical CT reports for detection of any type of fracture of the proximal femur, pelvis, or sacrum was 88%. For the small number of operatively treated proximal femoral fractures seen in the study, sensitivity of CT was 60% (3/5) and negative predictive value was 97%, although the relatively few patients needing fixation precludes statistical analysis.

  20. Diagnostic Accuracy of the MMSE in Detecting Probable and Possible Alzheimer's Disease in Ethnically Diverse Highly Educated Individuals: An Analysis of the NACC Database

    PubMed Central

    Spering, Cynthia C.; Hobson, Valerie; Lucas, John A.; Menon, Chloe V.; Hall, James R.

    2012-01-01

    Background. To validate and extend the findings of a raised cut score of O’Bryant and colleagues (O’Bryant SE, Humphreys JD, Smith GE, et al. Detecting dementia with the mini-mental state examination in highly educated individuals. Arch Neurol. 2008;65(7):963–967.) for the Mini-Mental State Examination in detecting cognitive dysfunction in a bilingual sample of highly educated ethnically diverse individuals. Methods. Archival data were reviewed from participants enrolled in the National Alzheimer's Coordinating Center minimum data set. Data on 7,093 individuals with 16 or more years of education were analyzed, including 2,337 cases with probable and possible Alzheimer's disease, 1,418 mild cognitive impairment patients, and 3,088 nondemented controls. Ethnic composition was characterized as follows: 6,296 Caucasians, 581 African Americans, 4 American Indians or Alaska natives, 2 native Hawaiians or Pacific Islanders, 149 Asians, 43 “Other,” and 18 of unknown origin. Results. Diagnostic accuracy estimates (sensitivity, specificity, and likelihood ratio) of Mini-Mental State Examination cut scores in detecting probable and possible Alzheimer's disease were examined. A standard Mini-Mental State Examination cut score of 24 (≤23) yielded a sensitivity of 0.58 and a specificity of 0.98 in detecting probable and possible Alzheimer's disease across ethnicities. A cut score of 27 (≤26) resulted in an improved balance of sensitivity and specificity (0.79 and 0.90, respectively). In the cognitively impaired group (mild cognitive impairment and probable and possible Alzheimer's disease), the standard cut score yielded a sensitivity of 0.38 and a specificity of 1.00 while raising the cut score to 27 resulted in an improved balance of 0.59 and 0.96 of sensitivity and specificity, respectively. Conclusions. These findings cross-validate our previous work and extend them to an ethnically diverse cohort. A higher cut score is needed to maximize diagnostic accuracy of the Mini-Mental State Examination in individuals with college degrees. PMID:22396476

  1. Validation of a surveillance case definition for arthritis.

    PubMed

    Sacks, Jeffrey J; Harrold, Leslie R; Helmick, Charles G; Gurwitz, Jerry H; Emani, Srinivas; Yood, Robert A

    2005-02-01

    To assess whether self-reports of chronic joint symptoms or doctor-diagnosed arthritis can validly identify persons with clinically verifiable arthritis. The Behavioral Risk Factor Surveillance System (BRFSS), a telephone health survey, defines a case of arthritis as a self-report of chronic joint symptoms (CJS) and/or doctor-diagnosed arthritis (DDx). A sample of health plan enrollees aged 45-64 years and >/= 65 years with upcoming annual physical examinations were surveyed by telephone using the 2002 BRFSS CJS and DDx questions. Based on responses (CJS+, DDx-; CJS-, DDx+; CJS+, DDx+; CJS-, DDx-), respondents were recruited to undergo a standardized clinical history and physical examination for arthritis (the gold standard for clinical validation). Weighted sensitivities and specificities of the case definition were calculated to adjust for sampling. Of 2180 persons completing the telephone questionnaire, 389 were examined; of these, 258 met the case definition and 131 did not. For those examined and aged 45 to 64 years (n = 179), 96 persons had arthritis confirmed, of whom 76 met the case definition. Among those examined and aged >/= 65 (n = 210), 150 had arthritis confirmed, of whom 124 met the case definition. Among those without clinical arthritis, 45 of 83 of those aged 45 to 64 years and 40 of 60 of those aged >/= 65 did not meet the case definition. For those aged 45 to 64 years, the weighted sensitivity of the case definition in this sample was 77.4% and the weighted specificity was 58.8%; for those aged >/= 65, the sensitivity was 83.6% and specificity 70.6%. CJS+ had higher sensitivity and lower specificity than DDx+ in the younger age group; CJS+ and DDx+ behaved more comparably in the older age group. The case definition based on self-reported CJS and/or DDx appeared to be sensitive in identifying arthritis, but specificity was lower than desirable for those under age 65 years. Better methods of ascertaining arthritis by self-report are needed. Until then, a change in the surveillance case definition for arthritis appears warranted.

  2. Comparison of Subjective Global Assessment and Protein Energy Wasting Score to Nutrition Evaluations Conducted by Registered Dietitian Nutritionists in Identifying Protein Energy Wasting Risk in Maintenance Hemodialysis Patients.

    PubMed

    Sum, Simon Siu-Man; Marcus, Andrea F; Blair, Debra; Olejnik, Laura A; Cao, Joyce; Parrott, J Scott; Peters, Emily N; Hand, Rosa K; Byham-Gray, Laura D

    2017-09-01

    To compare the 7-point subjective global assessment (SGA) and the protein energy wasting (PEW) score with nutrition evaluations conducted by registered dietitian nutritionists in identifying PEW risk in stage 5 chronic kidney disease patients on maintenance hemodialysis. This study is a secondary analysis of a cross-sectional study entitled "Development and Validation of a Predictive energy Equation in Hemodialysis". PEW risk identified by the 7-point SGA and the PEW score was compared against the nutrition evaluations conducted by registered dietitian nutritionists through data examination from the original study (reference standard). A total of 133 patients were included for the analysis. The sensitivity, specificity, positive and negative predictive value (PPV and NPV), positive and negative likelihood ratio (PLR and NLR) of both scoring tools were calculated when compared against the reference standard. The patients were predominately African American (n = 112, 84.2%), non-Hispanic (n = 101, 75.9%), and male (n = 80, 60.2%). Both the 7-point SGA (sensitivity = 78.6%, specificity = 59.1%, PPV = 33.9%, NPV = 91.2%, PLR = 1.9, and NLR = 0.4) and the PEW score (sensitivity = 100%, specificity = 28.6%, PPV = 27.2%, NPV = 100%, PLR = 1.4, and NLR = 0) were more sensitive than specific in identifying PEW risk. The 7-point SGA may miss 21.4% patients having PEW and falsely identify 40.9% of patients who do not have PEW. The PEW score can identify PEW risk in all patients, but 71.4% of patients identified may not have PEW risk. Both the 7-point SGA and the PEW score could identify PEW risk. The 7-point SGA was more specific, and the PEW score was more sensitive. Both scoring tools were found to be clinically confident in identifying patients who were actually not at PEW risk. Copyright © 2017 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  3. The Sensitivity and Specificity of Loop-Mediated Isothermal Amplification (LAMP) Assay for Tuberculosis Diagnosis in Adults with Chronic Cough in Malawi.

    PubMed

    Nliwasa, Marriott; MacPherson, Peter; Chisala, Palesa; Kamdolozi, Mercy; Khundi, McEwen; Kaswaswa, Kruger; Mwapasa, Mphatso; Msefula, Chisomo; Sohn, Hojoon; Flach, Clare; Corbett, Elizabeth L

    2016-01-01

    Current tuberculosis diagnostics lack sensitivity, and are expensive. Highly accurate, rapid and cheaper diagnostic tests are required for point of care use in low resource settings with high HIV prevalence. To investigate the sensitivity and specificity, and cost of loop-mediated isothermal amplification (LAMP) assay for tuberculosis diagnosis in adults with chronic cough compared to Xpert® MTB/RIF, fluorescence smear microscopy. Between October 2013 and March 2014, consecutive adults at a primary care clinic were screened for cough, offered HIV testing and assessed for tuberculosis using LAMP, Xpert® MTB/RIF and fluorescence smear microscopy. Sensitivity and specificity (with culture as reference standard), and costs were estimated. Of 273 adults recruited, 44.3% (121/273) were HIV-positive and 19.4% (53/273) had bacteriogically confirmed tuberculosis. The sensitivity of LAMP compared to culture was 65.0% (95% CI: 48.3% to 79.4%) with 100% (95% CI: 98.0% to 100%) specificity. The sensitivity of Xpert® MTB/RIF (77.5%, 95% CI: 61.5% to 89.2%) was similar to that of LAMP, p = 0.132. The sensitivity of concentrated fluorescence smear microscopy with routine double reading (87.5%, 95% CI: 73.2% to 95.8%) was higher than that of LAMP, p = 0.020. All three tests had high specificity. The lowest cost per test of LAMP was at batch size of 14 samples (US$ 9.98); this was lower than Xpert® MTB/RIF (US$ 13.38) but higher than fluorescence smear microscopy (US$ 0.65). The sensitivity of LAMP was similar to Xpert® MTB/RIF but lower than fluorescence smear microscopy; all three tests had high specificity. These findings support the Malawi policy that recommends a combination of fluorescence smear microscopy and Xpert® MTB/RIF prioritised for people living with HIV, already found to be smear-negative, or being considered for retreatment of tuberculosis.

  4. The Sensitivity and Specificity of Loop-Mediated Isothermal Amplification (LAMP) Assay for Tuberculosis Diagnosis in Adults with Chronic Cough in Malawi

    PubMed Central

    Nliwasa, Marriott; MacPherson, Peter; Chisala, Palesa; Kamdolozi, Mercy; Khundi, McEwen; Kaswaswa, Kruger; Mwapasa, Mphatso; Msefula, Chisomo; Sohn, Hojoon; Flach, Clare; Corbett, Elizabeth L.

    2016-01-01

    Background Current tuberculosis diagnostics lack sensitivity, and are expensive. Highly accurate, rapid and cheaper diagnostic tests are required for point of care use in low resource settings with high HIV prevalence. Objective To investigate the sensitivity and specificity, and cost of loop-mediated isothermal amplification (LAMP) assay for tuberculosis diagnosis in adults with chronic cough compared to Xpert® MTB/RIF, fluorescence smear microscopy. Methods Between October 2013 and March 2014, consecutive adults at a primary care clinic were screened for cough, offered HIV testing and assessed for tuberculosis using LAMP, Xpert® MTB/RIF and fluorescence smear microscopy. Sensitivity and specificity (with culture as reference standard), and costs were estimated. Results Of 273 adults recruited, 44.3% (121/273) were HIV-positive and 19.4% (53/273) had bacteriogically confirmed tuberculosis. The sensitivity of LAMP compared to culture was 65.0% (95% CI: 48.3% to 79.4%) with 100% (95% CI: 98.0% to 100%) specificity. The sensitivity of Xpert® MTB/RIF (77.5%, 95% CI: 61.5% to 89.2%) was similar to that of LAMP, p = 0.132. The sensitivity of concentrated fluorescence smear microscopy with routine double reading (87.5%, 95% CI: 73.2% to 95.8%) was higher than that of LAMP, p = 0.020. All three tests had high specificity. The lowest cost per test of LAMP was at batch size of 14 samples (US$ 9.98); this was lower than Xpert® MTB/RIF (US$ 13.38) but higher than fluorescence smear microscopy (US$ 0.65). Conclusion The sensitivity of LAMP was similar to Xpert® MTB/RIF but lower than fluorescence smear microscopy; all three tests had high specificity. These findings support the Malawi policy that recommends a combination of fluorescence smear microscopy and Xpert® MTB/RIF prioritised for people living with HIV, already found to be smear-negative, or being considered for retreatment of tuberculosis. PMID:27171380

  5. Evaluation of an automated breast 3D-ultrasound system by comparing it with hand-held ultrasound (HHUS) and mammography.

    PubMed

    Golatta, Michael; Baggs, Christina; Schweitzer-Martin, Mirjam; Domschke, Christoph; Schott, Sarah; Harcos, Aba; Scharf, Alexander; Junkermann, Hans; Rauch, Geraldine; Rom, Joachim; Sohn, Christof; Heil, Joerg

    2015-04-01

    Automated three-dimensional (3D) breast ultrasound (US) systems are meant to overcome the shortcomings of hand-held ultrasound (HHUS). The aim of this study is to analyze and compare clinical performance of an automated 3D-US system by comparing it with HHUS, mammography and the clinical gold standard (defined as the combination of HHUS, mammography and-if indicated-histology). Nine hundred and eighty three patients (=1,966 breasts) were enrolled in this monocentric, explorative and prospective cohort study. All examinations were analyzed blinded to the patients´ history and to the results of the routine imaging. The agreement of automated 3D-US with HHUS, mammography and the gold standard was assessed with kappa statistics. Sensitivity, specificity and positive and negative predictive value were calculated to assess the test performance. Blinded to the results of the gold standard the agreement between automated 3D-US and HHUS or mammography was fair, given by a Kappa coefficient of 0.31 (95% CI [0.26;0.36], p < 0.0001) and 0.25 (95% CI [0.2;0.3], p < 0.0001), respectively. Our results showed a high negative predictive value (NPV) of 98%, a high specificity of 85% and a sensitivity of 74% based on the cases with US-guided biopsy. Including the cases where the lesion was seen in a second-look automated 3D-US the sensitivity improved to 84% (NPV = 99%, specificity = 85%). The results of this study let us suggest, that automated 3D-US might be a helpful new tool in breast imaging, especially in screening.

  6. Comparison of the sensitivity and specificity of 5 image sets of dual-energy computed tomography for detecting first-pass myocardial perfusion defects compared with positron emission tomography.

    PubMed

    Li, Wenhuan; Zhu, Xiaolian; Li, Jing; Peng, Cheng; Chen, Nan; Qi, Zhigang; Yang, Qi; Gao, Yan; Zhao, Yang; Sun, Kai; Li, Kuncheng

    2014-12-01

    The sensitivity and specificity of 5 different image sets of dual-energy computed tomography (DECT) for the detection of first-pass myocardial perfusion defects have not systematically been compared using positron emission tomography (PET) as a reference standard. Forty-nine consecutive patients, with known or strongly suspected of coronary artery disease, were prospectively enrolled in our study. Cardiac DECT was performed at rest state using a second-generation 128-slice dual-source CT. The DECT data were reconstructed to iodine maps, monoenergetic images, 100 kV images, nonlinearly blended images, and linearly blended images by different postprocessing techniques. The myocardial perfusion defects on DECT images were visually assessed by 5 observers, using standard 17-segment model. Diagnostic accuracy of 5 image sets was assessed using nitrogen-13 ammonia PET as the gold standard. Discrimination was quantified using the area under the receiver operating characteristic curve (AUC), and AUCs were compared using the method of DeLong. The DECT and PET examinations were successfully completed in 30 patients and a total of 90 territories and 510 segments were analyzed. Cardiac PET revealed myocardial perfusion defects in 56 territories (62%) and 209 segments (41%). The AUC of iodine maps, monoenergetic images, 100 kV images, nonlinearly blended images, and linearly blended images were 0.986, 0.934, 0.913, 0.881, and 0.871, respectively, on a per-territory basis. These values were 0.922, 0.813, 0.779, 0.763, and 0.728, respectively, on a per-segment basis. DECT iodine maps shows high sensitivity and specificity, and is superior to other DECT image sets for the detection of myocardial perfusion defects in the first-pass myocardial perfusion.

  7. Low Dose MDCT with Tube Current Modulation: Role in Detection of Urolithiasis and Patient Effective Dose Reduction

    PubMed Central

    Kakkar, Chandan; Sripathi, Smiti; Parakh, Anushri; Shrivastav, Rajendra

    2016-01-01

    Introduction Urolithiasis is one of the major, recurring problem in young individuals and CT being the commonest diagnostic modality used. In order to reduce the radiation dose to the patient who are young and as stone formation is a recurring process; one of the simplest way would be, low dose CT along with tube current modulation. Aim Aim of this study was to compare the sensitivity and specificity of low dose (70mAs) with standard dose (250mAs) protocol in detecting urolithiasis and to define the tube current and mean effective patient dose by these protocols. Materials and Methods A prospective study was conducted in 200 patients over a period of 2 years with acute flank pain presentation. CT was performed in 100 cases with standard dose and another 100 with low dose protocol using tube current modulation. Sensitivity and specificity for calculus detection, percentage reduction of dose and tube current with low dose protocol was calculated. Results Urolithiasis was detected in 138 patients, 67 were examined by high dose and 71 were by low dose protocol. Sensitivity and Specificity of low dose protocol was 97.1% and 96.4% with similar results found in high BMI patients. Tube current modulation resulted in reduction of effective tube current by 12.17%. The mean effective patient dose for standard dose was 10.33 mSv whereas 2.92 mSv for low dose with 51.13–53.8% reduction in low dose protocol. Conclusion The study has reinforced that low-dose CT with tube current modulation is appropriate for diagnosis of urolithiasis with significant reduction in tube current and patient effective dose. PMID:27437322

  8. Low Dose MDCT with Tube Current Modulation: Role in Detection of Urolithiasis and Patient Effective Dose Reduction.

    PubMed

    Koteshwar, Prakashini; Kakkar, Chandan; Sripathi, Smiti; Parakh, Anushri; Shrivastav, Rajendra

    2016-05-01

    Urolithiasis is one of the major, recurring problem in young individuals and CT being the commonest diagnostic modality used. In order to reduce the radiation dose to the patient who are young and as stone formation is a recurring process; one of the simplest way would be, low dose CT along with tube current modulation. Aim of this study was to compare the sensitivity and specificity of low dose (70mAs) with standard dose (250mAs) protocol in detecting urolithiasis and to define the tube current and mean effective patient dose by these protocols. A prospective study was conducted in 200 patients over a period of 2 years with acute flank pain presentation. CT was performed in 100 cases with standard dose and another 100 with low dose protocol using tube current modulation. Sensitivity and specificity for calculus detection, percentage reduction of dose and tube current with low dose protocol was calculated. Urolithiasis was detected in 138 patients, 67 were examined by high dose and 71 were by low dose protocol. Sensitivity and Specificity of low dose protocol was 97.1% and 96.4% with similar results found in high BMI patients. Tube current modulation resulted in reduction of effective tube current by 12.17%. The mean effective patient dose for standard dose was 10.33 mSv whereas 2.92 mSv for low dose with 51.13-53.8% reduction in low dose protocol. The study has reinforced that low-dose CT with tube current modulation is appropriate for diagnosis of urolithiasis with significant reduction in tube current and patient effective dose.

  9. True versus Apparent Malaria Infection Prevalence: The Contribution of a Bayesian Approach

    PubMed Central

    Claes, Filip; Van Hong, Nguyen; Torres, Kathy; Mao, Sokny; Van den Eede, Peter; Thi Thinh, Ta; Gamboa, Dioni; Sochantha, Tho; Thang, Ngo Duc; Coosemans, Marc; Büscher, Philippe; D'Alessandro, Umberto; Berkvens, Dirk; Erhart, Annette

    2011-01-01

    Aims To present a new approach for estimating the “true prevalence” of malaria and apply it to datasets from Peru, Vietnam, and Cambodia. Methods Bayesian models were developed for estimating both the malaria prevalence using different diagnostic tests (microscopy, PCR & ELISA), without the need of a gold standard, and the tests' characteristics. Several sources of information, i.e. data, expert opinions and other sources of knowledge can be integrated into the model. This approach resulting in an optimal and harmonized estimate of malaria infection prevalence, with no conflict between the different sources of information, was tested on data from Peru, Vietnam and Cambodia. Results Malaria sero-prevalence was relatively low in all sites, with ELISA showing the highest estimates. The sensitivity of microscopy and ELISA were statistically lower in Vietnam than in the other sites. Similarly, the specificities of microscopy, ELISA and PCR were significantly lower in Vietnam than in the other sites. In Vietnam and Peru, microscopy was closer to the “true” estimate than the other 2 tests while as expected ELISA, with its lower specificity, usually overestimated the prevalence. Conclusions Bayesian methods are useful for analyzing prevalence results when no gold standard diagnostic test is available. Though some results are expected, e.g. PCR more sensitive than microscopy, a standardized and context-independent quantification of the diagnostic tests' characteristics (sensitivity and specificity) and the underlying malaria prevalence may be useful for comparing different sites. Indeed, the use of a single diagnostic technique could strongly bias the prevalence estimation. This limitation can be circumvented by using a Bayesian framework taking into account the imperfect characteristics of the currently available diagnostic tests. As discussed in the paper, this approach may further support global malaria burden estimation initiatives. PMID:21364745

  10. Cost-effectiveness of various methods of diagnosing hypersensitivity to Alternaria.

    PubMed

    Escudero, A I; Sánchez-Guerrero, I M; Mora, A M; Soriano, V; López, J D; García, F J; Negro, J M; Hernández, J; Pagán, J A

    1993-01-01

    This study was undertaken for two reasons: 1) It is more difficult to diagnose hypersensitivity to molds than to other allergens, so an evaluation of diagnostic tests was needed. 2) Alternaria is the principal cause of mold sensitization in our area. Sixty-six patients (20 +/- 4 years) were selected and divided into two groups. Group A was made up of patients with rhinitis and/or asthma due to Alternaria sensitization. Group B consisted of patients sensitized to other allergens and patients with nonrespiratory allergic disorders. Skin tests (prick and intradermal), challenge tests (conjunctival, nasal, and bronchial), and specific IgE determination were performed for all patients. A biologically standardized extract of Alternaria tenuis (Alergia e Inmunología Abelló, S. A., Madrid, Spain) obtained from a single batch was used for all tests. Our diagnostic criterion was a clinical history of rhinitis or asthma that coincided with the results of nasal/bronchial challenge. The diagnostic value of the other tests was compared to this criterion. In the group of rhinitic patients, skin tests and conjunctival challenge were more sensitive than specific IgE determination. In asthmatic patients, the most sensitive techniques were nasal and conjunctival challenges, followed by prick and intradermal skin tests, and, lastly, serum specific IgE determination. When rhinitis and asthma were considered jointly, the most sensitive test was conjunctival challenge, followed by skin-prick and intradermal tests. All tests had the same specificity, regardless of disorder. Nasal challenge was positive in all patients. Skin tests are easy to perform, cheap, non-traumatic for the patient, and sufficiently specific and sensitive for the diagnosis of Alternaria hypersensitivity.(ABSTRACT TRUNCATED AT 250 WORDS)

  11. Development and clinical performance of high throughput loop-mediated isothermal amplification for detection of malaria

    PubMed Central

    Perera, Rushini S.; Ding, Xavier C.; Tully, Frank; Oliver, James; Bright, Nigel; Bell, David; Chiodini, Peter L.; Gonzalez, Iveth J.; Polley, Spencer D.

    2017-01-01

    Background Accurate and efficient detection of sub-microscopic malaria infections is crucial for enabling rapid treatment and interruption of transmission. Commercially available malaria LAMP kits have excellent diagnostic performance, though throughput is limited by the need to prepare samples individually. Here, we evaluate the clinical performance of a newly developed high throughput (HTP) sample processing system for use in conjunction with the Eiken malaria LAMP kit. Methods The HTP system utilised dried blood spots (DBS) and liquid whole blood (WB), with parallel sample processing of 94 samples per run. The system was evaluated using 699 samples of known infection status pre-determined by gold standard nested PCR. Results The sensitivity and specificity of WB-HTP-LAMP was 98.6% (95% CI, 95.7–100), and 99.7% (95% CI, 99.2–100); sensitivity of DBS-HTP-LAMP was 97.1% (95% CI, 93.1–100), and specificity 100% against PCR. At parasite densities greater or equal to 2 parasites/μL, WB and DBS HTP-LAMP showed 100% sensitivity and specificity against PCR. At densities less than 2 p/μL, WB-HTP-LAMP sensitivity was 88.9% (95% CI, 77.1–100) and specificity was 99.7% (95% CI, 99.2–100); sensitivity and specificity of DBS-HTP-LAMP was 77.8% (95% CI, 54.3–99.5) and 100% respectively. Conclusions The HTP-LAMP system is a highly sensitive diagnostic test, with the potential to allow large scale population screening in malaria elimination campaigns. PMID:28166235

  12. Stereometric parameters change vs. Topographic Change Analysis (TCA) agreement in Heidelberg Retina Tomography III (HRT-3) early detection of clinical significant glaucoma progression.

    PubMed

    Dascalu, A M; Cherecheanu, A P; Stana, D; Voinea, L; Ciuluvica, R; Savlovschi, C; Serban, D

    2014-01-01

    to investigate the sensitivity and specificity of the stereometric parameters change analysis vs. Topographic Change Analysis in early detection of glaucoma progression. 81 patients with POAG were monitored for 4 years (GAT monthly, SAP at every 6 months, optic disc photographs and HRT3 yearly). The exclusion criteria were other optic disc or retinal pathology; topographic standard deviation (TSD>30; inter-test variation of reference height>25 μm. The criterion for structural progression was the following: at least 20 adjacent super-pixels with a clinically significant decrease in height (>5%). 16 patients of the total 81 presented structural progression on TCA. The most useful stereometric parameters for the early detection of glaucoma progression were the following: Rim Area change (sensitivity 100%, specificity 74.2% for a "cut-off " value of -0.05), C/D Area change (sensitivity 85.7%, specificity 71.5% for a "cut off " value of 0.02), C/D linear change (sensitivity 85.7%, specificity 71.5% for a "cut-off " value of 0.02), Rim Volume change (sensitivity 71.4%, specificity 88.8% for a "cut-off " value of -0.04). RNFL Thickness change (<0) was highly sensitive (82%), but less specific for glaucoma progression (45,2%). Changes of the other stereometric parameters have a limited diagnostic value for the early detection of glaucoma progression. TCA is a valuable tool for the assessment of the structural progression in glaucoma patients and its inter-test variability is low. On long-term, the quantitative analysis according to stereometric parameters change is also very important. The most relevant parameters to detect progression are RA, C/D Area, Linear C/D and RV.

  13. Clinical Effectiveness of Prospectively Reported Sonographic Twinkling Artifact for the Diagnosis of Renal Calculus in Patients Without Known Urolithiasis.

    PubMed

    Masch, William R; Cohan, Richard H; Ellis, James H; Dillman, Jonathan R; Rubin, Jonathan M; Davenport, Matthew S

    2016-02-01

    The purpose of this study was to determine the clinical effectiveness of prospectively reported sonographic twinkling artifact for the diagnosis of renal calculus in patients without known urolithiasis. All ultrasound reports finalized in one health system from June 15, 2011, to June 14, 2014, that contained the words "twinkle" or "twinkling" in reference to suspected renal calculus were identified. Patients with known urolithiasis or lack of a suitable reference standard (unenhanced abdominal CT with ≤ 2.5-mm slice thickness performed ≤ 30 days after ultrasound) were excluded. The sensitivity, specificity, and positive likelihood ratio of sonographic twinkling artifact for the diagnosis of renal calculus were calculated by renal unit and stratified by two additional diagnostic features for calcification (echogenic focus, posterior acoustic shadowing). Eighty-five patients formed the study population. Isolated sonographic twinkling artifact had sensitivity of 0.78 (82/105), specificity of 0.40 (26/65), and a positive likelihood ratio of 1.30 for the diagnosis of renal calculus. Specificity and positive likelihood ratio improved and sensitivity declined when the following additional diagnostic features were present: sonographic twinkling artifact and echogenic focus (sensitivity, 0.61 [64/105]; specificity, 0.65 [42/65]; positive likelihood ratio, 1.72); sonographic twinkling artifact and posterior acoustic shadowing (sensitivity, 0.31 [33/105]; specificity, 0.95 [62/65]; positive likelihood ratio, 6.81); all three features (sensitivity, 0.31 [33/105]; specificity, 0.95 [62/65]; positive likelihood ratio, 6.81). Isolated sonographic twinkling artifact has a high false-positive rate (60%) for the diagnosis of renal calculus in patients without known urolithiasis.

  14. Diagnostic performance of body mass index to identify excess body fat in children with cerebral palsy.

    PubMed

    Duran, Ibrahim; Schulze, Josefa; Martakis, KyriakoS; Stark, Christina; Schoenau, Eckhard

    2018-03-07

    To assess the diagnostic performance of body mass index (BMI) cut-off values according to recommendations of the World Health Organization (WHO), the World Obesity Federation (WOF), and the German Society for Adiposity (DAG) to identify excess body fat in children with cerebral palsy (CP). The present study was a monocentric retrospective analysis of prospectively collected data among children and adolescents with CP participating in a rehabilitation programme. Excess body fat was defined as a body fat percentage above the 85th centile assessed by dual-energy X-ray absorptiometry. In total, 329 children (181 males, 148 females) with CP were eligible for analysis. The mean age was 12 years 4 months (standard deviation 2y 9mo). The BMI cut-off values for 'overweight' according to the WHO, WOF, and DAG showed the following sensitivities and specificities for the prediction of excess body fat in our population: WHO: sensitivity 0.768 (95% confidence interval [CI] 0.636-0.870), specificity 0.894 (95% CI 0.851-0.928); WOF: sensitivity 0.696 (95% CI 0.559-0.812), specificity 0.934 (95% CI 0.898-0.960); DAG: sensitivity 0.411 (95% CI 0.281-0.550), specificity 0.993 (95% CI 0.974-0.999). Body mass index showed high specificity, but low sensitivity in children with CP. Thus, 'normal-weight obese' children with CP were overlooked, when assessing excess body fat only using BMI. Excess body fat in children with cerebral palsy (CP) is less common than previously reported. Body mass index (BMI) had high specificity but low sensitivity in detecting excess body fat in children with CP. BMI evaluation criteria of the German Society for Adiposity could be improved in children with CP. © 2018 Mac Keith Press.

  15. Accuracy of Rapid Fecal Calprotectin Test in Monitoring Inflammatory Bowel Diseases Under Treatment with TNFα Antagonists.

    PubMed

    Tursi, Antonio; Elisei, Walter; Picchio, Marcello; Giorgetti, GianMarco; Brandimarte, Giovanni

    2015-05-01

    Anti-TNFα antibodies are effective in treating inflammatory bowel diseases (IBDs) unresponsive to the standard treatments. Information about the role of rapid fecal calprotectin (FC) in monitoring ambulatory IBD patients under treatment with anti-TNFα is lacking. Our aim was to assess the accuracy of rapid FC in monitoring those patients. Seventy-two patients (38 males, 34 females, mean age 42.5 years, range 23-57 years), affected by ulcerative colitis (UC) (20 patients) or by Crohn's disease (CD) (52 patients) were treated with anti-TNFα antibodies. FC was assessed by a rapid semiquantitative test. With respect to the absence of clinical remission, FC test showed sensitivity of 71.8 %, specificity of 65.2 %, PPV of 41.8 %, and NPV of 86.9 %. In UC patients, FC test showed a sensitivity of 66.7 %, a specificity of 56.1 %, a PPV of 18.2 %, and a NPV of 92.0 %. In CD patients, FC test showed sensitivity of 70.6 %, specificity of 65.2 %, PPV of 50.0 %, and NPV of 81.8 %. With respect to the presence of endoscopic lesions, FC test showed sensitivity of 73.5 %, specificity of 96.0 %, PPV of 96.2 %, and NPV of 72.7 %. In UC patients, FC test showed sensitivity of 47.2 %, specificity of 84.6 %, PPV of 89.5 %, and NPV of 36.7 %. In CD patients, FC test showed sensitivity of 90.1 %, specificity of 79.7 %, PPV of 71.9 %, and NPV of 93.3 %. Diagnostic accuracy of rapid FC seems better in predicting persistence of endoscopic lesions than clinical remission in IBD patients under treatment with anti-TNFα.

  16. Optimal CINAHL search strategies for identifying therapy studies and review articles.

    PubMed

    Wong, Sharon S L; Wilczynski, Nancy L; Haynes, R Brian

    2006-01-01

    To design optimal search strategies for locating sound therapy studies and review articles in CiNAHL in the year 2000. An analytic survey was conducted, comparing hand searches of 75 journals with retrievals from CINAHL for 5,020 candidate search terms and 17,900 combinations for therapy and 5,977 combinations for review articles. All articles were rated with purpose and quality indicators. Candidate search strategies were used in CINAHL, and the retrievals were compared with results of the hand searches. The proposed search strategies were treated as "diagnostic tests" for sound studies and the manual review of the literature was treated as the "gold standard." Operating characteristics of the search strategies were calculated. Of the 1,383 articles about treatment, 506 (36.6%) met basic criteria for scientific merit and 127 (17.9%) of the 711 articles classified as a review met the criteria for systematic reviews. For locating sound treatment studies, a three-term strategy maximized sensitivity at 99.4% but with compromised specificity at 58.3%, and a two-term strategy maximized specificity at 98.5% but with compromised sensitivity at 52.0%. For detecting systematic reviews, a three-term strategy maximized sensitivity at 91.3% while keeping specificity high at 95.4%, and a single-term strategy maximized specificity at 99.6% but with compromised sensitivity at 42.5%. Three-term search strategies optimizing sensitivity and specificity achieved these values over 91% for detecting sound treatment studies and over 76% for detecting systematic reviews. Search strategies combining indexing terms and text words can achieve high sensitivity and specificity for retrieving sound treatment studies and review articles in CINAHL.

  17. [Validity of expired carbon monoxide and urine cotinine using dipstick method to assess smoking status].

    PubMed

    Park, Su San; Lee, Ju Yul; Cho, Sung-Il

    2007-07-01

    We investigated the validity of the dipstick method (Mossman Associates Inc. USA) and the expired CO method to distinguish between smokers and nonsmokers. We also elucidated the related factors of the two methods. This study included 244 smokers and 50 ex-smokers, recruited from smoking cessation clinics at 4 local public health centers, who had quit for over 4 weeks. We calculated the sensitivity, specificity and Kappa coefficient of each method for validity. We obtained ROC curve, predictive value and agreement to determine the cutoff of expired air CO method. Finally, we elucidated the related factors and compared their effect powers using the standardized regression coefficient. The dipstick method showed a sensitivity of 92.6%, specificity of 96.0% and Kappa coefficient of 0.79. The best cutoff value to distinguish smokers was 5-6 ppm. At 5 ppm, the expired CO method showed a sensitivity of 94.3%, specificity of 82.0% and Kappa coefficient of 0.73. And at 6 ppm, sensitivity, specificity and Kappa coefficient were 88.5%, 86.0% and 0.64, respectively. Therefore, the dipstick method had higher sensitivity and specificity than the expired CO method. The dipstick and expired CO methods were significantly increased with increasing smoking amount. With longer time since the last smoking, expired CO showed a rapid decrease after 4 hours, whereas the dipstick method showed relatively stable levels for more than 4 hours. The dipstick and expired CO methods were both good indicators for assessing smoking status. However, the former showed higher sensitivity and specificity and stable levels over longer hours after smoking, compared to the expired CO method.

  18. Univariate and bivariate likelihood-based meta-analysis methods performed comparably when marginal sensitivity and specificity were the targets of inference.

    PubMed

    Dahabreh, Issa J; Trikalinos, Thomas A; Lau, Joseph; Schmid, Christopher H

    2017-03-01

    To compare statistical methods for meta-analysis of sensitivity and specificity of medical tests (e.g., diagnostic or screening tests). We constructed a database of PubMed-indexed meta-analyses of test performance from which 2 × 2 tables for each included study could be extracted. We reanalyzed the data using univariate and bivariate random effects models fit with inverse variance and maximum likelihood methods. Analyses were performed using both normal and binomial likelihoods to describe within-study variability. The bivariate model using the binomial likelihood was also fit using a fully Bayesian approach. We use two worked examples-thoracic computerized tomography to detect aortic injury and rapid prescreening of Papanicolaou smears to detect cytological abnormalities-to highlight that different meta-analysis approaches can produce different results. We also present results from reanalysis of 308 meta-analyses of sensitivity and specificity. Models using the normal approximation produced sensitivity and specificity estimates closer to 50% and smaller standard errors compared to models using the binomial likelihood; absolute differences of 5% or greater were observed in 12% and 5% of meta-analyses for sensitivity and specificity, respectively. Results from univariate and bivariate random effects models were similar, regardless of estimation method. Maximum likelihood and Bayesian methods produced almost identical summary estimates under the bivariate model; however, Bayesian analyses indicated greater uncertainty around those estimates. Bivariate models produced imprecise estimates of the between-study correlation of sensitivity and specificity. Differences between methods were larger with increasing proportion of studies that were small or required a continuity correction. The binomial likelihood should be used to model within-study variability. Univariate and bivariate models give similar estimates of the marginal distributions for sensitivity and specificity. Bayesian methods fully quantify uncertainty and their ability to incorporate external evidence may be useful for imprecisely estimated parameters. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Sensitivity and Specificity of the Coma Recovery Scale--Revised Total Score in Detection of Conscious Awareness.

    PubMed

    Bodien, Yelena G; Carlowicz, Cecilia A; Chatelle, Camille; Giacino, Joseph T

    2016-03-01

    To describe the sensitivity and specificity of Coma Recovery Scale-Revised (CRS-R) total scores in detecting conscious awareness. Data were retrospectively extracted from the medical records of patients enrolled in a specialized disorders of consciousness (DOC) program. Sensitivity and specificity analyses were completed using CRS-R-derived diagnoses of minimally conscious state (MCS) or emerged from minimally conscious state (EMCS) as the reference standard for conscious awareness and the total CRS-R score as the test criterion. A receiver operating characteristic curve was constructed to demonstrate the optimal CRS-R total cutoff score for maximizing sensitivity and specificity. Specialized DOC program. Patients enrolled in the DOC program (N=252, 157 men; mean age, 49y; mean time from injury, 48d; traumatic etiology, n=127; nontraumatic etiology, n=125; diagnosis of coma or vegetative state, n=70; diagnosis of MCS or EMCS, n=182). Not applicable. Sensitivity and specificity of CRS-R total scores in detecting conscious awareness. A CRS-R total score of 10 or higher yielded a sensitivity of .78 for correct identification of patients in MCS or EMCS, and a specificity of 1.00 for correct identification of patients who did not meet criteria for either of these diagnoses (ie, were diagnosed with vegetative state or coma). The area under the curve in the receiver operating characteristic curve analysis is .98. A total CRS-R score of 10 or higher provides strong evidence of conscious awareness but resulted in a false-negative diagnostic error in 22% of patients who demonstrated conscious awareness based on CRS-R diagnostic criteria. A cutoff score of 8 provides the best balance between sensitivity and specificity, accurately classifying 93% of cases. The optimal total score cutoff will vary depending on the user's objective. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  20. Development of SYBR Green and TaqMan quantitative real-time PCR assays for hepatopancreatic parvovirus (HPV) infecting Penaeus monodon in India.

    PubMed

    Yadav, Reena; Paria, Anutosh; Mankame, Smruti; Makesh, M; Chaudhari, Aparna; Rajendran, K V

    2015-12-01

    Hepatopancreatic parvovirus (HPV) infects Penaeus monodon and causes mortality in the larval stages. Further, it has been implicated in the growth retardation in cultured P. monodon. Though different geographical isolates of HPV show large sequence variations, a sensitive PCR assay specific to Indian isolate has not yet been reported. Here, we developed a sensitive SYBR Green-based and TaqMan real-time PCR for the detection and quantification of the virus. A 441-bp PCR amplicon was cloned in pTZ57 R/T vector and the plasmid copy number was estimated. A 10-fold serial dilution of the plasmid DNA from 1 × 10(9) copies to 1 copy was prepared and used as the standard. The primers were tested initially using the standard on a conventional PCR format to determine the linearity of detection. The standards were further tested on real-time PCR format using SYBR Green and TaqMan chemistry and standard curves were generated based on the Ct values from three well replicates for each dilution. The assays were found to be sensitive, specific and reproducible with a wide dynamic range (1 × 10(9) to 10 copies) with coefficient of regression (R(2)) > 0.99, calculated average slope -3.196 for SYBR Green assay whereas, for TaqMan assay it was >0.99 and -3.367, respectively. The intra- and inter-assay variance of the Ct values ranged from 0.26% to 0.94% and 0.12% to 0.81%, respectively, for SYBR Green assay, and the inter-assay variance of the Ct values for TaqMan assay ranged from 0.07% to 1.93%. The specificity of the assays was proved by testing other DNA viruses of shrimp such as WSSV, IHHNV and MBV. Standardized assays were further tested to detect and quantify HPV in the post-larvae of P. monodon. The result was further compared with conventional PCR to test the reproducibility of the test. The assay was also used to screen Litopeneaus vannamei, Macrobrachium rosenbergii and Scylla serrata for HPV. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Influence of personal characteristics of individual women on sensitivity and specificity of mammography in the Million Women Study: cohort study

    PubMed Central

    Banks, Emily; Reeves, Gillian; Beral, Valerie; Bull, Diana; Crossley, Barbara; Simmonds, Moya; Hilton, Elizabeth; Bailey, Stephen; Barrett, Nigel; Briers, Peter; English, Ruth; Jackson, Alan; Kutt, Elizabeth; Lavelle, Janet; Rockall, Linda; Wallis, Matthew G; Wilson, Mary; Patnick, Julietta

    2004-01-01

    Objectives To examine how lifestyle, hormonal, and other factors influence the sensitivity and specificity of mammography. Methods Women recruited into the Million Women Study completed a questionnaire about various personal factors before routine mammographic screening. A sample of 122 355 women aged 50-64 years were followed for outcome of screening and incident breast cancer in the next 12 months. Sensitivity and specificity were calculated by using standard definitions, with adjustment for potential confounding factors. Results Breast cancer was diagnosed in 726 (0.6%) women, 629 in screen positive and 97 in screen negative women; 3885 (3.2%) were screen positive but had no subsequent diagnosis of breast cancer. Overall sensitivity was 86.6% and specificity was 96.8%. Three factors had an adverse effect on both measures: use of hormone replacement therapy (sensitivity: 83.0% (95% confidence interval 77.4% to 87.6%), 84.7% (73.9% to 91.6%), and 92.1% (87.6% to 95.0%); specificity: 96.8% (96.6% to 97.0%), 97.8% (97.5% to 98.0%), and 98.1% (98.0% to 98.2%), respectively, for current, past, and never use); previous breast surgery v no previous breast surgery (sensitivity: 83.5% (75.7% to 89.1%) v 89.4% (86.5% to 91.8%); specificity: 96.2% (95.8% to 96.5%) v 97.4% (97.3% to 97.5%), respectively); and body mass index < 25 v ≥ 25 (sensitivity: 85.7% (81.2% to 89.3%) v 91.0% (87.5% to 93.6%); specificity: 97.2% (97.0% to 97.3%) v 97.4% (97.3% to 97.6%), respectively). Neither sensitivity nor specificity varied significantly according to age, family history of breast cancer, parity, past oral contraceptive use, tubal ligation, physical activity, smoking, or alcohol consumption. Conclusions The efficiency, and possibly the effectiveness, of mammographic screening is lower in users of hormone replacement therapy, in women with previous breast surgery, and in thin women compared with other women. PMID:15331472

  2. Accuracy of the clinical diagnosis of vaginitis compared with a DNA probe laboratory standard.

    PubMed

    Lowe, Nancy K; Neal, Jeremy L; Ryan-Wenger, Nancy A

    2009-01-01

    To estimate the accuracy of the clinical diagnosis of the three most common causes of acute vulvovaginal symptoms (bacterial vaginosis, candidiasis vaginitis, and trichomoniasis vaginalis) using a traditional, standardized clinical diagnostic protocol compared with a DNA probe laboratory standard. This prospective clinical comparative study had a sample of 535 active-duty United States military women presenting with vulvovaginal symptoms. Clinical diagnoses were made by research staff using a standardized protocol of history, physical examination including pelvic examination, determination of vaginal pH, vaginal fluid amines test, and wet-prep microscopy. Vaginal fluid samples were obtained for DNA analysis. The research clinicians were blinded to the DNA results. The participants described a presenting symptom of abnormal discharge (50%), itching/irritation (33%), malodor (10%), burning (4%), or others such as vulvar pain and vaginal discomfort. According to laboratory standard, there were 225 cases (42%) of bacterial vaginosis, 76 cases (14%) of candidiasis vaginitis, 8 cases (1.5%) of trichomoniasis vaginalis, 87 cases of mixed infections (16%), and 139 negative cases (26%). For each single infection, the clinical diagnosis had a sensitivity and specificity of 80.8% and 70.0% for bacterial vaginosis, 83.8% and 84.8% for candidiasis vaginitis, and 84.6% and 99.6% for trichomoniasis vaginalis when compared with the DNA probe standard. Compared with a DNA probe standard, clinical diagnosis is 81-85% sensitive and 70-99% specific for bacterial vaginosis, Candida vaginitis, and trichomoniasis. Even under research conditions that provided clinicians with sufficient time and materials to conduct a thorough and standardized clinical evaluation, the diagnosis and, therefore, subsequent treatment of these common vaginal problems remains difficult. II.

  3. Proof of the quantitative potential of immunofluorescence by mass spectrometry.

    PubMed

    Toki, Maria I; Cecchi, Fabiola; Hembrough, Todd; Syrigos, Konstantinos N; Rimm, David L

    2017-03-01

    Protein expression in formalin-fixed, paraffin-embedded patient tissue is routinely measured by Immunohistochemistry (IHC). However, IHC has been shown to be subject to variability in sensitivity, specificity and reproducibility, and is generally, at best, considered semi-quantitative. Mass spectrometry (MS) is considered by many to be the criterion standard for protein measurement, offering high sensitivity, specificity, and objective molecular quantification. Here, we seek to show that quantitative immunofluorescence (QIF) with standardization can achieve quantitative results comparable to MS. Epidermal growth factor receptor (EGFR) was measured by quantitative immunofluorescence in 15 cell lines with a wide range of EGFR expression, using different primary antibody concentrations, including the optimal signal-to-noise concentration after quantitative titration. QIF target measurement was then compared to the absolute EGFR concentration measured by Liquid Tissue-selected reaction monitoring mass spectrometry. The best agreement between the two assays was found when the EGFR primary antibody was used at the optimal signal-to-noise concentration, revealing a strong linear regression (R 2 =0.88). This demonstrates that quantitative optimization of titration by calculation of signal-to-noise ratio allows QIF to be standardized to MS and can therefore be used to assess absolute protein concentration in a linear and reproducible manner.

  4. The Clinical Utility of ASRS-v1.1 for Identifying ADHD in Alcoholics Using PRISM as the Reference Standard.

    PubMed

    Reyes, Maria M; Schneekloth, Terry D; Hitschfeld, Mario J; Geske, Jennifer R; Atkinson, David L; Karpyak, Victor M

    2016-05-02

    The objective was to assess the clinical utility of the Adult ADHD Self-Report Scale (ASRS-v1.1) in identifying ADHD in alcoholics using the Psychiatric Research Interview for Substance and Mental Disorders (PRISM) as the diagnostic "gold standard." We performed a secondary analysis of data from 379 treatment-seeking alcoholics who completed the ASRS-v1.1 and the ADHD module of the PRISM. Data analysis included descriptive statistics. The prevalence of ADHD was 7.7% (95% CI = [5.4, 10.8]). The positive predictive value (PPV) of the ASRS-v1.1 was 18.1% (95% CI = [12.4, 25.7]) and the negative predictive value (NPV) was 97.6% (95% CI = [94.9, 98.9]). The ASRS-v1.1 demonstrated a sensitivity of 79.3% (95% CI = [61.6, 90.2]) and a specificity of 70.3% (95% CI = [65.3, 74.8]). The ASRS-v1.1 demonstrated acceptable sensitivity and specificity in a sample of treatment-seeking alcoholics when compared with the PRISM as the reference standard for ADHD diagnosis. © The Author(s) 2016.

  5. Obesity classification in military personnel: a comparison of body fat, waist circumference, and body mass index measurements.

    PubMed

    Heinrich, Katie M; Jitnarin, Nattinee; Suminski, Richard R; Berkel, LaVerne; Hunter, Christine M; Alvarez, Lisa; Brundige, Antionette R; Peterson, Alan L; Foreyt, John P; Haddock, C Keith; Poston, Walker S C

    2008-01-01

    The purpose of this study was to evaluate obesity classifications from body fat percentage (BF%), body mass index (BMI), and waist circumference (WC). A total of 451 overweight/obese active duty military personnel completed all three assessments. Most were obese (men, 81%; women, 98%) using National Institutes of Health (NIH) BF% standards (men, >25%; women, >30%). Using the higher World Health Organization (WHO) BF >35% standard, 86% of women were obese. BMI (55.5% and 51.4%) and WC (21.4% and 31.9%) obesity rates were substantially lower for men and women, respectively (p < 0.05). BMI/WC were accurate discriminators for BF% obesity (theta for all comparisons >0.75, p < 0.001). Optimal cutoff points were lower than NIH/WHO standards; WC = 100 cm and BMI = 29 maximized sensitivity and specificity for men, and WC = 79 cm and BMI = 25.5 (NIH) or WC = 83 cm and BMI = 26 (WHO) maximized sensitivity and specificity for women. Both WC and BMI measures had high rates of false negatives compared to BF%. However, at a population level, WC/BMI are useful obesity measures, demonstrating fair-to-high discriminatory power.

  6. Evaluation of basal DNA damage and oxidative stress in Wistar rat leukocytes after exposure to microwave radiation.

    PubMed

    Garaj-Vrhovac, Vera; Gajski, Goran; Trosić, Ivancica; Pavicić, Ivan

    2009-05-17

    The aim of this study was to assess whether microwave-induced DNA damage is basal or it is also generated through reactive oxygen species (ROS) formation. After having irradiated Wistar rats with 915MHz microwave radiation, we assessed different DNA alterations in peripheral leukocytes using standard and formamidopyrimidine DNA-glycosylase (Fpg)-modified comet assay. The first is a sensitive tool for detecting primary DNA damage, and the second is much more specific for detecting oxidative damage. The animals were irradiated for 1h a day for 2 weeks at a field power density of 2.4W/m(2), and the whole-body average specific absorption rate (SAR) of 0.6W/kg. Both the standard and the Fpg-modified comet assay detected increased DNA damage in blood leukocytes of the exposed rats. The significant increase in Fpg-detected DNA damage in the exposed rats suggests that oxidative stress is likely to be responsible. DNA damage detected by the standard comet assay indicates that some other mechanisms may also be involved. In addition, both methods served proved sensitive enough to measure basal and oxidative DNA damage after long-term exposure to 915MHz microwave radiation in vivo.

  7. Differentiating epileptic from non-epileptic high frequency intracerebral EEG signals with measures of wavelet entropy.

    PubMed

    Mooij, Anne H; Frauscher, Birgit; Amiri, Mina; Otte, Willem M; Gotman, Jean

    2016-12-01

    To assess whether there is a difference in the background activity in the ripple band (80-200Hz) between epileptic and non-epileptic channels, and to assess whether this difference is sufficient for their reliable separation. We calculated mean and standard deviation of wavelet entropy in 303 non-epileptic and 334 epileptic channels from 50 patients with intracerebral depth electrodes and used these measures as predictors in a multivariable logistic regression model. We assessed sensitivity, positive predictive value (PPV) and negative predictive value (NPV) based on a probability threshold corresponding to 90% specificity. The probability of a channel being epileptic increased with higher mean (p=0.004) and particularly with higher standard deviation (p<0.0001). The performance of the model was however not sufficient for fully classifying the channels. With a threshold corresponding to 90% specificity, sensitivity was 37%, PPV was 80%, and NPV was 56%. A channel with a high standard deviation of entropy is likely to be epileptic; with a threshold corresponding to 90% specificity our model can reliably select a subset of epileptic channels. Most studies have concentrated on brief ripple events. We showed that background activity in the ripple band also has some ability to discriminate epileptic channels. Copyright © 2016 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  8. Diagnostic Accuracy of Abdominal Ultrasound for Diagnosis of Acute Appendicitis: Systematic Review and Meta-analysis.

    PubMed

    Giljaca, Vanja; Nadarevic, Tin; Poropat, Goran; Nadarevic, Vesna Stefanac; Stimac, Davor

    2017-03-01

    To determine the diagnostic accuracy of abdominal ultrasound (US) for the diagnosis of acute appendicitis (AA), in terms of sensitivity, specificity and post-test probabilities for positive and negative result. A systematic search of MEDLINE, Embase, The Cochrane library and Science Citation Index Expanded from January 1994 to October 2014 was performed. Two authors independently evaluated studies for inclusion, extracted data and performed analyses. The reference standard for evaluation of final diagnosis was pathohistological report on tissue obtained at appendectomy. Summary sensitivity, specificity and post-test probability of AA after positive and negative result of US with corresponding 95% confidence intervals (CI) were calculated. Out of 3306 references identified through electronic searches, 17 reports met the inclusion criteria, with 2841 included participants. The summary sensitivity and specificity of US for diagnosis of AA were 69% (95% CI 59-78%) and 81% (95% CI 73-88%), respectively. At the median pretest probability of AA of 76.4%, the post-test probability for a positive and negative result of US was 92% (95% CI 88-95%) and 55% (95% CI 46-63%), respectively. Abdominal ultrasound does not seem to have a role in the diagnostic pathway for diagnosis of AA in suspected patients. The summary sensitivity and specificity of US do not exceed that of physical examination. Patients that require additional diagnostic workup should be referred to more sensitive and specific diagnostic procedures, such as computed tomography.

  9. Applying Classification Trees to Hospital Administrative Data to Identify Patients with Lower Gastrointestinal Bleeding

    PubMed Central

    Siddique, Juned; Ruhnke, Gregory W.; Flores, Andrea; Prochaska, Micah T.; Paesch, Elizabeth; Meltzer, David O.; Whelan, Chad T.

    2015-01-01

    Background Lower gastrointestinal bleeding (LGIB) is a common cause of acute hospitalization. Currently, there is no accepted standard for identifying patients with LGIB in hospital administrative data. The objective of this study was to develop and validate a set of classification algorithms that use hospital administrative data to identify LGIB. Methods Our sample consists of patients admitted between July 1, 2001 and June 30, 2003 (derivation cohort) and July 1, 2003 and June 30, 2005 (validation cohort) to the general medicine inpatient service of the University of Chicago Hospital, a large urban academic medical center. Confirmed cases of LGIB in both cohorts were determined by reviewing the charts of those patients who had at least 1 of 36 principal or secondary International Classification of Diseases, Ninth revision, Clinical Modification (ICD-9-CM) diagnosis codes associated with LGIB. Classification trees were used on the data of the derivation cohort to develop a set of decision rules for identifying patients with LGIB. These rules were then applied to the validation cohort to assess their performance. Results Three classification algorithms were identified and validated: a high specificity rule with 80.1% sensitivity and 95.8% specificity, a rule that balances sensitivity and specificity (87.8% sensitivity, 90.9% specificity), and a high sensitivity rule with 100% sensitivity and 91.0% specificity. Conclusion These classification algorithms can be used in future studies to evaluate resource utilization and assess outcomes associated with LGIB without the use of chart review. PMID:26406318

  10. Sensitivity and specificity of the AdenoPlus point-of-care system in detecting adenovirus in conjunctivitis patients at an ophthalmic emergency department: a diagnostic accuracy study.

    PubMed

    Kam, K Y Ronald; Ong, Hon Shing; Bunce, Catey; Ogunbowale, Lola; Verma, Seema

    2015-09-01

    To estimate the diagnostic accuracy (sensitivity and specificity) of the AdenoPlus point-of-care adenoviral test compared to PCR in an ophthalmic accident and emergency service. These findings were compared with those of a previous study. This was a prospective diagnostic accuracy study on 121 patients presenting to an emergency eye unit with a clinical picture of acute adenoviral conjunctivitis. AdenoPlus testing was carried out on one eye of each patient and a PCR analysis was also performed on a swab taken from the same eye. AdenoPlus and PCR results were interpreted by masked personnel. Sensitivity and specificity for the AdenoPlus test were calculated using PCR results as the reference standard. 121 patients were enrolled and 109 met the inclusion criteria. 43 patients (39.4%) tested positive for adenovirus by PCR analysis. The sensitivity of the AdenoPlus swab in detecting adenovirus was 39.5% (17/43, 95% CI 26% to 54%) and specificity was 95.5% (63/66, 95% CI 87% to 98%) compared to PCR. The AdenoPlus test has a high specificity for diagnosing adenoviral conjunctivitis, but in this clinical setting, we could not reproduce the high sensitivity that has been previously published. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  11. Comparison of Three Different Commercial Kits for the Human Papilloma Virus Genotyping.

    PubMed

    Lim, Yong Kwan; Choi, Jee-Hye; Park, Serah; Kweon, Oh Joo; Park, Ae Ja

    2016-11-01

    High-risk type human papilloma virus (HPV) is the most important cause of cervical cancer. Recently, real-time polymerase chain reaction and reverse blot hybridization assay-based HPV DNA genotyping kits are developed. So, we compared the performances of different three HPV genotyping kits using different analytical principles and methods. Two hundred positive and 100 negative cervical swab specimens were used. DNA was extracted and all samples were tested by the MolecuTech REBA HPV-ID, Anyplex II HPV28 Detection, and HPVDNAChip. Direct sequencing was performed as a reference method for confirming high-risk HPV genotypes 16, 18, 45, 52, and 58. Although high-level agreement results were observed in negative samples, three kits showed decreased interassay agreement as screening setting in positive samples. Comparing the genotyping results, three assays showed acceptable sensitivity and specificity for the detection of HPV 16 and 18. Otherwise, various sensitivities showed in the detection of HPV 45, 52, and 58. The three assays had dissimilar performance of HPV screening capacity and exhibited moderate level of concordance in HPV genotyping. These discrepant results were unavoidable due to difference in type-specific analytical sensitivity and lack of standardization; therefore, we suggested that the efforts to standardization of HPV genotyping kits and adjusting analytical sensitivity would be important for the best clinical performance. © 2016 Wiley Periodicals, Inc.

  12. Wilms' Tumor 1 Gene Expression Using a Standardized European LeukemiaNet-Certified Assay Compared to Other Methods for Detection of Minimal Residual Disease in Myelodysplastic Syndrome and Acute Myelogenous Leukemia after Allogeneic Blood Stem Cell Transplantation.

    PubMed

    Rautenberg, Christina; Pechtel, Sabrina; Hildebrandt, Barbara; Betz, Beate; Dienst, Ariane; Nachtkamp, Kathrin; Kondakci, Mustafa; Geyh, Stefanie; Wieczorek, Dagmar; Haas, Rainer; Germing, Ulrich; Kobbe, Guido; Schroeder, Thomas

    2018-05-16

    Overexpression of the Wilms' tumor 1 (WT1) gene is informative in many patients with acute myelogenous leukemia (AML) and myelodysplastic syndromes (MDS) and is measurable in peripheral blood (PB). Despite these advantages, WT1 has not broadly been established as a marker for minimal residual disease (MRD) monitoring after allogeneic hematopoietic stem cell transplantation (allo-HSCT) due to limited patient numbers, differing sample sources, and nonstandardized in-house methods. To estimate the value of WT1 as an MRD marker, we serially quantified PB WT1 expression using a standardized European LeukemiaNet-certified assay in 59 patients with AML and MDS after allo-HSCT. We compared its performance with routine methods such as chimerism, XY-fluorescence in situ hybridization (FISH), disease-specific cytogenetic, and molecular analyses, which were accessible in 100%, 34%, 68%, and 37%, respectively. Twenty-four patients (41%) relapsed within a median of 126 days after allo-HSCT, and 20 of them showed at least 1 elevated WT1 value above the validated cutoff. The other 35 patients (59%) remained in complete remission, and only 1 patient had a transient increase in WT1 expression. This reflects a sensitivity of 83% and a specificity of 97% for WT1 and appears to be favorable compared with the sensitivities and specificities observed for chimerism (33% and 91%), XY-FISH (67% and 73%), cytogenetic (33% and 77%), and molecular (78% and 85%) analyses. Further supporting its predictive impact, elevated WT1 expression prompted an earlier BM biopsy and consecutively the diagnosis of relapse in 62% of patients. The results of this real-life experience imply that PB WT1 expression is measurable by a standardized assay and predicts imminent relapse after allo-HSCT with high sensitivity and specificity in most patients with AML and MDS. Copyright © 2018. Published by Elsevier Inc.

  13. Biomimetic ELISA detection of malachite green based on molecularly imprinted polymer film.

    PubMed

    Li, Lu; Peng, Ai-Hong; Lin, Zheng-Zhong; Zhong, Hui-Ping; Chen, Xiao-Mei; Huang, Zhi-Yong

    2017-08-15

    A highly selective and sensitive enzyme-linked immunosorbent assay (ELISA) was developed for the detection of malachite green (MG) using a molecularly imprinted polymer (MIP) film as bionic antibody. The MIP film, based on the self-polymerization of dopamine, was fabricated on the surfaces of a 96-well microplate. It showed specific recognition for MG in aqueous solution. A direct competitive ELISA method was established with the sensitivity reaching 10.31μgL -1 and the detection limit being 0.3μgL -1 . The cross-reactivity of two structural analogues to MG was less than 10%. The average recovery tested by MG standard spiking was 88.8% for bass and 90.4% for water, and the relative standard deviations were less than 3.6%. All the above results indicated that the developed method could be used to detect MG in fish and water samples rapidly, specifically and accurately. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Meta-analysis of diagnostic tests accounting for disease prevalence: a new model using trivariate copulas.

    PubMed

    Hoyer, A; Kuss, O

    2015-05-20

    In real life and somewhat contrary to biostatistical textbook knowledge, sensitivity and specificity (and not only predictive values) of diagnostic tests can vary with the underlying prevalence of disease. In meta-analysis of diagnostic studies, accounting for this fact naturally leads to a trivariate expansion of the traditional bivariate logistic regression model with random study effects. In this paper, a new model is proposed using trivariate copulas and beta-binomial marginal distributions for sensitivity, specificity, and prevalence as an expansion of the bivariate model. Two different copulas are used, the trivariate Gaussian copula and a trivariate vine copula based on the bivariate Plackett copula. This model has a closed-form likelihood, so standard software (e.g., SAS PROC NLMIXED) can be used. The results of a simulation study have shown that the copula models perform at least as good but frequently better than the standard model. The methods are illustrated by two examples. Copyright © 2015 John Wiley & Sons, Ltd.

  15. Accuracy of a new clean-catch technique for diagnosis of urinary tract infection in infants younger than 90 days of age

    PubMed Central

    Herreros, María Luisa; Tagarro, Alfredo; García-Pose, Araceli; Sánchez, Aida; Cañete, Alfonso; Gili, Pablo

    2015-01-01

    OBJECTIVE: To evaluate the accuracy of diagnosing urinary tract infections using a new, recently described, standardized clean-catch collection technique. METHODS: Cross-sectional study of infants <90 days old admitted due to fever without a source, with two matched samples of urine obtained using two different methods: clean-catch standardized stimulation technique and bladder catheterization. RESULTS: Sixty paired urine cultures were obtained. The median age was 44-days-old. Seventeen percent were male infants. Clean-catch technique sensitivity was 97% (95% CI 82% to 100%) and specificity was 89% (95% CI 65% to 98%). The contamination rate of clean-catch samples was lower (5%) than the contamination rate of catheter specimens (8%). CONCLUSIONS: The sensitivity and specificity of urine cultures obtained using the clean-catch method through the new technique were accurate and the contamination rate was low. These results suggest that this technique is a valuable, alternative method for urinary tract infection diagnosis. PMID:26435675

  16. Evaluation of echocardiography in the management of elderly patients with heart failure.

    PubMed

    Hendry, A; Hacking, L; Langhorne, P; Vallance, R; MacDonald, J

    1999-09-01

    To determine the validity of a clinical diagnosis of systolic dysfunction in elderly patients with heart failure and assess the contribution of echocardiography to their management. 61 elderly patients with a diagnosis of heart failure in a geriatric assessment unit setting. Prospective study determining sensitivity, specificity and predictive values of a clinical and radiological diagnosis compared with echocardiographic standard. Proposed management was compared before and after echocardiography. Clinical assessment was highly sensitive (93%) but lacked specificity (32%). Combining radiological and clinical diagnoses increased specificity to 58%. Echocardiography revised the lead cardiac diagnosis for 28% of patients and influenced patient management plans for 41%. For elderly patients with heart failure, echocardiography improves diagnostic accuracy and identifies those patients with potential to benefit from angiotensin-converting enzyme inhibitors.

  17. Sensitivity and specificity of digital retinal imaging for screening diabetic retinopathy.

    PubMed

    Lopez-Bastida, J; Cabrera-Lopez, F; Serrano-Aguilar, P

    2007-04-01

    To assess the effectiveness of a non-mydriatic digital camera (45 degrees -30 degrees photographs) compared with the reference method for screening diabetic retinopathy. Type 1 and 2 diabetic patients (n = 773; 1546 eyes) underwent screening for diabetic retinopathy in a prospective observational study. Hospital-based non-mydriatic digital retinal imaging by a consultant specialist in retinal diseases was compared with slit-lamp biomicroscopy and indirect ophthalmoscopy through dilated pupils, as a gold standard, previously performed in a community health centre by another consultant specialist in retinal diseases. The main outcome measures were sensitivity and specificity of screening methods and prevalence of diabetic retinopathy. The prevalence of any form of diabetic retinopathy was 42.4% (n = 328); the prevalence of sight-threatening including macular oedema and proliferative retinopathy was 9.6% (n = 74). Sensitivity of detection of any diabetic retinopathy by digital imaging was 92% (95% confidence interval 90, 94). Specificity of detection of any diabetic retinopathy was 96% (95, 98). The predictive value of the negative tests was 94% and of a positive test 95%. For sight-threatening retinopathy digital imaging had a sensitivity of 100%. A high sensitivity and specificity are essential for an effective screening programme. These results confirm digital retinal imaging with a non-mydriatic camera as an effective option in community-based screening programmes for diabetic retinopathy.

  18. Ecotoxicity of boric acid in standard laboratory tests with plants and soil organisms.

    PubMed

    Princz, Juliska; Becker, Leonie; Scheffczyk, Adam; Stephenson, Gladys; Scroggins, Rick; Moser, Thomas; Römbke, Jörg

    2017-05-01

    To verify the continuous sensitivity of ecotoxicological tests (mainly the test organisms), reference substances with known toxicity are regularly tested. Ideally, this substance(s) would lack specificity in its mode action, be bioavailable and readily attainable with cost-effective means of chemical characterization. Boric acid has satisfied these criteria, but has most recently been characterized as a substance of very high concern, due to reproductive effects in humans, thus limiting its recommendation as an ideal reference toxicant. However, there is probably no other chemical for which ecotoxicity in soil has been so intensively studied; an extensive literature review yielded lethal (including avoidance) and sublethal data for 38 taxa. The ecotoxicity data were evaluated using species sensitivity distributions, collectively across all taxa, and separately according to species type, endpoints, soil type and duration. The lack of specificity in the mode of action yielded broad toxicity among soil taxa and soil types, and provided a collective approach to assessing species sensitivity, while taking into consideration differences in test methodologies and exposure durations. Toxicity was species-specific with Folsomia candida and enchytraied species demonstrating the most sensitivity; among plants, the following trend occurred: dicotyledonous (more sensitive) ≫ monocotyledonous ≫ gymnosperm species. Sensitivity was also time and endpoint specific, with endpoints such as lethality and avoidance being less sensitive than reproduction effects. Furthermore, given the breadth of data and toxicity demonstrated by boric acid, lessons learned from its evaluation are discussed to recommend the properties required by an ideal reference substance for the soil compartment.

  19. Diagnostic accuracy of apparent diffusion coefficient and 123I-metaiodobenzylguanidine for differentiation of multiple system atrophy and Parkinson's disease.

    PubMed

    Umemura, Atsushi; Oeda, Tomoko; Hayashi, Ryutaro; Tomita, Satoshi; Kohsaka, Masayuki; Yamamoto, Kenji; Sawada, Hideyuki

    2013-01-01

    It is often hard to differentiate Parkinson's disease (PD) and parkinsonian variant of multiple system atrophy (MSA-P), especially in the early stages. Cardiac sympathetic denervation and putaminal rarefaction are specific findings for PD and MSA-P, respectively. We investigated diagnostic accuracy of putaminal apparent diffusion coefficient (ADC) test for MSA-P and (123)I-metaiodobenzylguanidine (MIBG) scintigram for PD, especially in early-stage patients. The referral standard diagnosis of PD and MSA-P were the diagnostic criteria of the United Kingdom Parkinson's Disease Society Brain Bank Criteria and the second consensus criteria, respectively. Based on the referral standard criteria, diagnostic accuracy [area under the receiver-operator characteristic curve (AUC), sensitivity and specificity] of the ADC and MIBG tests was estimated retrospectively. Diagnostic accuracy of these tests performed within 3 years of symptom onset was also investigated. ADC and MIBG tests were performed on 138 patients (20 MSA and 118 PD). AUC was 0.95 and 0.83 for the ADC and MIBG tests, respectively. Sensitivity and specificity were 85.0% and 89.0% for MSA-P diagnosis by ADC test and 67.0% and 80.0% for PD diagnosis by MIBG test. When these tests were restricted to patients with disease duration ≤ 3 years, the sensitivity and specificity were 75.0% and 91.4% for the ADC test (MSA-P diagnosis) and 47.7% and 92.3% for the MIBG test (PD diagnosis). Both tests were useful in differentiating between PD and MSA-P, even in the early stages. In early-stage patients, elevated putaminal ADC was a diagnostic marker for MSA-P. Despite high specificity of the MIBG test, careful neurological history and examinations were required for PD diagnosis because of possible false-negative results.

  20. Real-time loop-mediated isothermal amplification (RealAmp) for the species-specific identification of Plasmodium vivax.

    PubMed

    Patel, Jaymin C; Oberstaller, Jenna; Xayavong, Maniphet; Narayanan, Jothikumar; DeBarry, Jeremy D; Srinivasamoorthy, Ganesh; Villegas, Leopoldo; Escalante, Ananias A; DaSilva, Alexandre; Peterson, David S; Barnwell, John W; Kissinger, Jessica C; Udhayakumar, Venkatachalam; Lucchi, Naomi W

    2013-01-01

    Plasmodium vivax infections remain a major source of malaria-related morbidity and mortality. Early and accurate diagnosis is an integral component of effective malaria control programs. Conventional molecular diagnostic methods provide accurate results but are often resource-intensive, expensive, have a long turnaround time and are beyond the capacity of most malaria-endemic countries. Our laboratory has recently developed a new platform called RealAmp, which combines loop-mediated isothermal amplification (LAMP) with a portable tube scanner real-time isothermal instrument for the rapid detection of malaria parasites. Here we describe new primers for the detection of P. vivax using the RealAmp method. Three pairs of amplification primers required for this method were derived from a conserved DNA sequence unique to the P. vivax genome. The amplification was carried out at 64°C using SYBR Green or SYTO-9 intercalating dyes for 90 minutes with the tube scanner set to collect fluorescence signals at 1-minute intervals. Clinical samples of P. vivax and other human-infecting malaria parasite species were used to determine the sensitivity and specificity of the primers by comparing with an 18S ribosomal RNA-based nested PCR as the gold standard. The new set of primers consistently detected laboratory-maintained isolates of P. vivax from different parts of the world. The primers detected P. vivax in the clinical samples with 94.59% sensitivity (95% CI: 87.48-98.26%) and 100% specificity (95% CI: 90.40-100%) compared to the gold standard nested-PCR method. The new primers also proved to be more sensitive than the published species-specific primers specifically developed for the LAMP method in detecting P. vivax.

  1. A Comparative Analysis of Coprologic Diagnostic Methods for Detection of Toxoplama gondii in Cats

    PubMed Central

    Salant, Harold; Spira, Dan T.; Hamburger, Joseph

    2010-01-01

    The relative role of transmission of Toxoplasma gondii infection from cats to humans appears to have recently increased in certain areas. Large-scale screening of oocyst shedding in cats cannot rely on microscopy because oocyst identification lacks sensitivity and specificity, or on bioassays, which require test animals and weeks before examination. We compared a sensitive and species-specific coprologic–polymerase chain reaction (copro-PCR) for detection of T. gondii infected cats with microscopy and a bioassay. In experimentally infected cats followed over time, microscopy was positive occasionally, and positive copro-PCR and bioassay results were obtained continuously from days 2 to 24 post-infection. The copro-PCR is at least as sensitive and specific as the bioassay and is capable of detecting infective oocysts during cat infection. Therefore, this procedure can be used as the new gold standard for determining potential cat infectivity. Its technologic advantages over the bioassay make it superior for large-scale screening of cats. PMID:20439968

  2. Chronic pesticide poisoning from persistent low-dose exposures in Ecuadorean floriculture workers: toward validating a low-cost test battery.

    PubMed

    Breilh, Jaime; Pagliccia, Nino; Yassi, Annalee

    2012-01-01

    Chronic pesticide poisoning is difficult to detect. We sought to develop a low-cost test battery for settings such as Ecuador's floriculture industry. First we had to develop a case definition; as with all occupational diseases a case had to have both sufficient effective dose and associated health effects. For the former, using canonical discriminant analysis, we found that adding measures of protection and overall environmental stressors to occupational category and duration of exposure was useful. For the latter, factor analysis suggested three distinct manifestations of pesticide poisoning. We then determined sensitivity and specificity of various combinations of symptoms and simple neurotoxicity tests from the Pentox questionnaire, and found that doing so increased sensitivity and specificity compared to use of acethylcholinesterase alone--the current screening standard. While sensitivity and specificity varied with different case definitions, our results support the development of a low-cost test battery for screening in such settings.

  3. Nanoparticle-mediated knockdown of DNA repair sensitizes cells to radiotherapy and extends survival in a genetic mouse model of glioblastoma.

    PubMed

    Kievit, Forrest M; Wang, Kui; Ozawa, Tatsuya; Tarudji, Aria W; Silber, John R; Holland, Eric C; Ellenbogen, Richard G; Zhang, Miqin

    2017-10-01

    Glioblastoma (GBM) remains incurable, and recurrent tumors rarely respond to standard-of-care radiation and chemo-therapies. Therefore, strategies that enhance the effects of these therapies should provide significant benefits to GBM patients. We have developed a nanoparticle delivery vehicle that can stably bind and protect nucleic acids for specific delivery into brain tumor cells. These nanoparticles can deliver therapeutic siRNAs to sensitize GBM cells to radiotherapy and improve GBM treatment via systemic administration. We show that nanoparticle-mediated knockdown of the DNA repair protein apurinic endonuclease 1 (Ape1) sensitizes GBM cells to radiotherapy and extend survival in a genetic mouse model of GBM. Specific knockdown of Ape1 activity by 30% in brain tumor tissue doubled the extended survival achieved with radiotherapy alone. Ape1 is a promising target for increasing the effectiveness of radiotherapy, and nanoparticle-mediated delivery of siRNA is a promising strategy for tumor specific knockdown of Ape1. Copyright © 2017. Published by Elsevier Inc.

  4. Finding knowledge translation articles in CINAHL.

    PubMed

    Lokker, Cynthia; McKibbon, K Ann; Wilczynski, Nancy L; Haynes, R Brian; Ciliska, Donna; Dobbins, Maureen; Davis, David A; Straus, Sharon E

    2010-01-01

    The process of moving research into practice has a number of names including knowledge translation (KT). Researchers and decision makers need to be able to readily access the literature on KT for the field to grow and to evaluate the existing evidence. To develop and validate search filters for finding KT articles in the database Cumulative Index to Nursing and Allied Health (CINAHL). A gold standard database was constructed by hand searching and classifying articles from 12 journals as KT Content, KT Applications and KT Theory. Sensitivity, specificity, precision, and accuracy of the search filters. Optimized search filters had fairly low sensitivity and specificity for KT Content (58.4% and 64.9% respectively), while sensitivity and specificity increased for retrieving KT Application (67.5% and 70.2%) and KT Theory articles (70.4% and 77.8%). Search filter performance was suboptimal marking the broad base of disciplines and vocabularies used by KT researchers. Such diversity makes retrieval of KT studies in CINAHL difficult.

  5. Sensitivity and Specificity in Three Measures of Depression Among Mexican American Women.

    PubMed

    Valencia-Garcia, Dellanira; Bi, Xiaoyu; Ayón, Cecilia

    2017-06-01

    This paper examined the prevalence of depressive symptomotology among women of Mexican ancestry (N = 205), over the age of 18, of diverse incomes and nativity. We examined differences in rates of diagnosis by Spanish/English preference and the sensitivity and specificity of three common measures: the Patient Health Questionnaire (PHQ9), the Kessler Psychological Distress Scale (K-10), and depression questions from the Composite International Diagnostic Interview, Short Form (MDD CIDI-SF); PHQ9 was used as the "gold standard" measure. Results indicated 18-32 % of participants met criteria for depression with higher rates found among Spanish preference participants. The K-10 had significantly higher sensitivity (0.81) but lower specificity (0.79) than the MDD CIDI-SF items (0.57 and 0.89, respectively). This study suggests that the K-10 and MDD CIDI-SF measures are complementary to each other for screening of depressive symptomatology. Implications for cultural and linguistic assessment of depression are further discussed.

  6. Rapid detection of methicillin resistance in coagulase-negative staphylococci by a penicillin-binding protein 2a-specific latex agglutination test.

    PubMed

    Horstkotte, M A; Knobloch, J K; Rohde, H; Mack, D

    2001-10-01

    The detection of PBP 2a by the MRSA-Screen latex agglutination test with 201 clinical coagulase-negative staphylococci had an initial sensitivity of 98% and a high degree of specificity for Staphylococcus epidermidis strains compared to PCR for mecA. Determination of oxacillin MICs evaluated according to the new breakpoint (0.5 microg/ml) of the National Committee for Clinical Laboratory Standards exhibited an extremely low specificity for this population.

  7. Sensitivity and specificity of the FAMACHA(©) system in Suffolk sheep and crossbred Boer goats.

    PubMed

    Sotomaior, Cristina Santos; Rosalinski-Moraes, Fernanda; da Costa, Alane Rayana Barbosa; Maia, Dhéri; Monteiro, Alda Lúcia Gomes; van Wyk, Jan A

    2012-11-23

    Sheep and goats are the species of farm animal with the highest growth rate in Paraná State. The main problems facing Paraná State flocks are gastrointestinal parasites and anthelmintic resistance. One of the newest resources used to slow down the development of anthelmintic resistance is the FAMACHA(©) system, a selective method useful for controlling gastrointestinal verminosis in small ruminants. The purpose of the present research was to evaluate the sensitivity and specificity of the FAMACHA(©) system in sheep and goats and to compare the results for both species. The conjunctivae of 83 Suffolk ewes and 60 adult crossbred Boer does were evaluated by the same trained person using the FAMACHA(©) system. The packed cell value (PCV) served as the gold standard for clinical FAMACHA(©) evaluation. To calculate the sensitivity and specificity of the FAMACHA(©) system, different criteria were adopted in turn: animals classified as FAMACHA(©) (F(©)) 4 and 5, or 3, 4 and 5, were considered to be anemic (positive test), and animals classified as F(©)1, 2 and 3, or 1 and 2 were considered to be non-anemic (negative test). Three standard values of PCV, namely ≤19%, ≤18% or ≤15%, were used to confirm anemia. At all cut-off levels, the sensitivity increased if F(©)3 animals were included as being anemic. However, changes in levels of sensitivity were associated with reciprocal changes in specificity. The sensitivity was higher for sheep than for goats, excepting when the criteria included PCV≤18 and F(©)3, F(©)4 and F(©)5 were considered positive. In contrast, the specificity was always lower in sheep for any criteria adopted. Other than in goats, using the ≤15 cut-off level for sheep, it is possible to opt not to drench the animals that were shown to be F(©)3 because the sensitivity is still high, indicating that few animals that should have been drenched were overlooked. In goats, in contrast, the low sensitivity at all cut-off levels made it too risky to leave F(©)3 animals undrenched. Even though the number of correct treatments for goats was always higher than that for sheep, the opposite was true for the kappa index for all the criteria tested. Therefore, the FAMACHA(©) system is suitable for the identification of anemic animals of both species. It is necessary that all small ruminants classified as FAMACHA(©) level 3 are also treated to increase the sensitivity of the method. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. Allergy to cow's milk proteins: what contribution does hypersensitivity in skin tests have to this diagnosis?

    PubMed

    Costa, Aldo José Fernandes; Sarinho, Emanuel Sávio Cavalcanti; Motta, Maria Eugênia Farias Almeida; Gomes, Priscila Nogueira; de Oliveira de Melo, Sabrina Maria; da Silva, Giselia Alves Pontes

    2011-02-01

    Food allergy is an immunologically mediated adverse reaction to food protein. Cow's milk protein allergy (CMPA) is the most frequent type and is the one that is most difficult to diagnose. This study had the objective of analyzing the accuracy of hypersensitivity and specific IgE skin tests among children with CMPA and predominantly gastrointestinal clinical manifestations. The participants in this study were 192 children aged one and five (median of 2 yr). Among these, 122 underwent open oral challenge to the suspected food. After evaluating the sensitivity, specificity and positive and negative predictive values (respectively, PPV and NPV) of skin and specific IgE tests in relation to the gold standard (open oral challenge); all the children underwent the skin prick test (SPT), specific IgE test and atopy patch test (APT) for cow's milk, eggs, wheat and peanuts and the open oral challenge for the food to which the child was sensitive or had suspected sensitivity. Presence of food allergy was confirmed for 50 children (40.9%). Among these cases, 44/50 (88%) were of allergy to cow's milk protein. Children who presented a positive response to an oral challenge to cow's milk protein were considered to be cases, while the controls were children with negative response. Twenty-two of the 44 cases (50.0%) presented symptoms within the first 4 h after the challenge. The SPT presented 31.8% sensitivity, 90.3% specificity, 66.7% PPV and 68.4% NPV. The APT presented 25.0% sensitivity, 81.9% specificity, 45.8% PPV and 64.1% NPV. The specific IgE test presented, respectively, 20.5%, 88.9%, 52.9% and 64.6%. Despite the operational difficulty and the possible exposure risk, oral challenge is the best method for diagnosing CMPA, because of the low sensitivity and PPV of skin and specific IgE tests. © 2011 John Wiley & Sons A/S.

  9. The diagnosis of food allergy: a systematic review and meta-analysis.

    PubMed

    Soares-Weiser, K; Takwoingi, Y; Panesar, S S; Muraro, A; Werfel, T; Hoffmann-Sommergruber, K; Roberts, G; Halken, S; Poulsen, L; van Ree, R; Vlieg-Boerstra, B J; Sheikh, A

    2014-01-01

    We investigated the accuracy of tests used to diagnose food allergy. Skin prick tests (SPT), specific-IgE (sIgE), component-resolved diagnosis and the atopy patch test (APT) were compared with the reference standard of double-blind placebo-controlled food challenge. Seven databases were searched and international experts were contacted. Two reviewers independently identified studies, extracted data, and used QUADAS-2 to assess risk of bias. Where possible, meta-analysis was undertaken. Twenty-four (2831 participants) studies were included. For cows' milk allergy, the pooled sensitivities were 53% (95% CI 33-72), 88% (95 % CI 76-94), and 87% (95% CI 75-94), and specificities were 88% (95% CI 76-95), 68% (95% CI 56-77), and 48% (95% CI 36-59) for APT, SPT, and sIgE, respectively. For egg, pooled sensitivities were 92% (95% CI 80-97) and 93% (95% CI 82-98), and specificities were 58% (95% CI 49-67) and 49% (40-58%) for skin prick tests and specific-IgE. For wheat, pooled sensitivities were 73% (95% CI 56-85) and 83% (95% CI 69-92), and specificities were 73% (95% CI 48-89) and 43% (95% CI 20-69%) for SPT and sIgE. For soy, pooled sensitivities were 55% (95% CI 33-75) and 83% (95% CI 64-93), and specificities were 68% (95% CI 52-80) and 38% (95% CI 24-54) for SPT and sIgE. For peanut, pooled sensitivities were 95% (95% CI 88-98) and 96% (95% CI 92-98), and specificities were 61% (95% CI 47-74), and 59% (95% CI 45-72) for SPT and sIgE. The evidence base is limited and weak and is therefore difficult to interpret. Overall, SPT and sIgE appear sensitive although not specific for diagnosing IgE-mediated food allergy. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. Sensitivity of the ISO 6579:2002/Amd 1:2007 Standard Method for Detection of Salmonella spp. on Mesenteric Lymph Nodes from Slaughter Pigs

    PubMed Central

    Mainar-Jaime, R. C.; Andrés, S.; Vico, J. P.; San Román, B.; Garrido, V.

    2013-01-01

    The ISO 6579:2002/Amd 1:2007 (ISO) standard has been the bacteriological standard method used in the European Union for the detection of Salmonella spp. in pig mesenteric lymph nodes (MLN), but there are no published estimates of the diagnostic sensitivity (Se) of the method in this matrix. Here, the Se of the ISO (SeISO) was estimated on 675 samples selected from two populations with different Salmonella prevalences (14 farms with a ≥20% prevalence and 13 farms with a <20% prevalence) and through the use of latent-class models in concert with Bayesian inference, assuming 100% ISO specificity, and an invA-based PCR as the second diagnostic method. The SeISO was estimated to be close to 87%, while the sensitivity of the PCR reached up to 83.6% and its specificity was 97.4%. Interestingly, the bacteriological reanalysis of 33 potential false-negative (PCR-positive) samples allowed isolation of 19 (57.5%) new Salmonella strains, improving the overall diagnostic accuracy of the bacteriology. Considering the usual limitations of bacteriology regarding Se, these results support the adequacy of the ISO for the detection of Salmonella spp. from MLN and also that of the PCR-based method as an alternative or complementary (screening) test for the diagnosis of pig salmonellosis, particularly considering the cost and time benefits of the molecular procedure. PMID:23100334

  11. Pain sensitivity profiles in patients with advanced knee osteoarthritis

    PubMed Central

    Frey-Law, Laura A.; Bohr, Nicole L.; Sluka, Kathleen A.; Herr, Keela; Clark, Charles R.; Noiseux, Nicolas O.; Callaghan, John J; Zimmerman, M Bridget; Rakel, Barbara A.

    2016-01-01

    The development of patient profiles to subgroup individuals on a variety of variables has gained attention as a potential means to better inform clinical decision-making. Patterns of pain sensitivity response specific to quantitative sensory testing (QST) modality have been demonstrated in healthy subjects. It has not been determined if these patterns persist in a knee osteoarthritis population. In a sample of 218 participants, 19 QST measures along with pain, psychological factors, self-reported function, and quality of life were assessed prior to total knee arthroplasty. Component analysis was used to identify commonalities across the 19 QST assessments to produce standardized pain sensitivity factors. Cluster analysis then grouped individuals that exhibited similar patterns of standardized pain sensitivity component scores. The QST resulted in four pain sensitivity components: heat, punctate, temporal summation, and pressure. Cluster analysis resulted in five pain sensitivity profiles: a “low pressure pain” group, an “average pain” group, and three “high pain” sensitivity groups who were sensitive to different modalities (punctate, heat, and temporal summation). Pain and function differed between pain sensitivity profiles, along with sex distribution; however no differences in OA grade, medication use, or psychological traits were found. Residualizing QST data by age and sex resulted in similar components and pain sensitivity profiles. Further, these profiles are surprisingly similar to those reported in healthy populations suggesting that individual differences in pain sensitivity are a robust finding even in an older population with significant disease. PMID:27152688

  12. A method for identifying color vision deficiency malingering.

    PubMed

    Pouw, Andrew; Karanjia, Rustum; Sadun, Alfredo

    2017-03-01

    To propose a new test to identify color vision deficiency malingering. An online survey was distributed to 130 truly color vision deficient participants and 160 participants willing to simulate color vision deficiency. The survey contained three sets of six color-adjusted versions of the standard Ishihara color plates each, as well as one set of six control plates. The plates that best discriminated both participant groups were selected for a "balanced" test emphasizing both sensitivity and specificity. A "specific" test that prioritized high specificity was also created by selecting from these plates. Statistical measures of the test (sensitivity, specificity, and Youden index) were assessed at each possible cut-off threshold, and a receiver operating characteristic (ROC) function with its area under the curve (AUC) charted. The redshift plate set was identified as having the highest difference of means between groups (-58%, CI: -64 to -52%), as well as the widest gap between group modes. Statistical measures of the "balanced" test show an optimal cut-off of at least two incorrectly identified plates to suggest malingering (Youden index: 0.773, sensitivity: 83.3%, specificity: 94.0%, AUC of ROC 0.918). The "specific" test was able to identify color vision deficiency simulators with a specificity of 100% when using a cut-off of at least two incorrectly identified plates (Youden index 0.599, sensitivity 59.9%, specificity 100%, AUC of ROC 0.881). Our proposed test for identifying color vision deficiency malingering demonstrates a high degree of reliability with AUCs of 0.918 and 0.881 for the "balanced" and "specific" tests, respectively. A cut-off threshold of at least two missed plates on the "specific" test was able to identify color vision deficiency simulators with 100% specificity.

  13. [Clinical investigation of basophil activation test as a complementary test for house dust mite allergen].

    PubMed

    Ren, H L; Li, J D; Miao, Y H; Xu, T

    2018-03-01

    Objective: To investigate the clinical application of glass micro fiber basophil activation test (BAT) used as a complementary test for house dust mite allergen. Method: Forty patients with clinical diagnosed allergic rhinitis was test by three methods for house dust mite allergen, skin prick test(SPT),Immuno CAP sIgE, and BAT in vitro. The sensitivity and specificity of glass micro fiber were accessed, and the consistency between BAT, SPT, and Immuno sIgE was analyzed. As in vivo provocation was not performed, gold standard is regarded as the combination of medical history and positive reports of SPT and/or ImmunoCAP sIgE test. Result: Twentythree patients are diagnosed as house dust mite allergic rhinitis by gold standard. The sensitivity and specificity of glass micro fiber BAT were 60.9% and 88.2%, the sensitivity of SPT and sIgE was 87.0% and sIgE 73.9%. The correlation rates between BAT with SPT is 0.67( P <0.05), and sIgE 0.55( P <0.05). The accuracy, predictive value of positive and negative of BAT are 0.47,60.9%,88.2%.The Kappa values of BAT, SPT and sIgE with gold standard are 0.47,0.86,0.71. Conclusion: As a complementary test for house dust mite allergic rhinitis, BAT have a good consistency with SPT and sIgE, while as it has only moderate consistency with "gold standard", further studies are needed to prove its clinical significance. Copyright© by the Editorial Department of Journal of Clinical Otorhinolaryngology Head and Neck Surgery.

  14. Are clinical diagnoses of Alzheimer's disease and other dementias affected by education and self-reported race?

    PubMed

    Teresi, Jeanne A; Grober, Ellen; Eimicke, Joseph P; Ehrlich, Amy R

    2012-09-01

    A randomized controlled trial examined whether the diagnostic process for Alzheimer's disease and other dementias may be influenced by knowledge of the patient's education and/or self-reported race. Four conditions were implemented: diagnostic team knows (a) race and education, (b) education only, (c) race only, or (d) neither. Diagnosis and clinical staging was established at baseline, at Wave 2, and for a random sample of Wave 3 respondents by a consensus panel. At study end, a longitudinal, "gold standard" diagnosis was made for patients with follow-up data (71%). Group differences in Diagnostic and Statistical Manual of Mental Disorders (4th ed.; American Psychiatric Association, 1994) diagnosis were estimated using logistic regression and generalized estimating equations. Sensitivity and specificity were examined for baseline diagnosis in relation to the gold standard, longitudinal diagnosis. Despite equivalent status on all measured variables across waves, members of the "knows race only" group were less likely than those of other groups to receive a diagnosis of dementia. At final diagnosis, 19% of the "knows race only" group was diagnosed with dementia versus 38% to 40% in the other 3 conditions (p = .038). Examination of sensitivities and specificities of baseline diagnosis in relation to the gold standard diagnosis showed a nonsignificant trend for lower sensitivities in the knowing race conditions (0.3846), as contrasted with knowing education only (0.480) or neither (0.600). The finding that knowledge of race may influence the diagnostic process in some unknown way is timely, given the recent State-of-the-Science conference on Alzheimer's disease prevention, the authors of which called for information about and standardization of the diagnostic process. PsycINFO Database Record (c) 2012 APA, all rights reserved.

  15. Nephron segment specific microRNA biomarkers of pre-clinical drug-induced renal toxicity: Opportunities and challenges

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nassirpour, Rounak, E-mail: Rounak.nassirpour@pfiz

    Drug-induced nephrotoxicity is a common drug development complication for pharmaceutical companies. Sensitive, specific, translatable and non-invasive biomarkers of renal toxicity are urgently needed to diagnose nephron segment specific injury. The currently available gold standard biomarkers for nephrotoxicity are not kidney-specific, lack sensitivity for early detection, and are not suitable for renal damage localization (glomerular vs tubulointerstitial injury). MicroRNAs (miRNAs) are increasingly gaining momentum as promising biomarkers of various organ toxicities, including drug induced renal injury. This is mostly due to their stability in easily accessible biofluids, ease of developing nucleic acids detection compared to protein detection assays, as well asmore » their interspecies translatability. Increasing concordance of miRNA findings by standardizing methodology most suitable for their detection and quantitation, as well as characterization of their expression pattern in a cell type specific manner, will accelerate progress toward validation of these miRNAs as biomarkers in pre-clinical, and clinical settings. This review aims to highlight the current pre-clinical findings surrounding miRNAs as biomarkers in two important segments of the nephron, the glomerulus and tubules. - Highlights: • miRNAs are promising biomarkers of drug-induced kidney injury. • Summarized pre-clinical miRNA biomarkers of drug-induced nephrotoxicity. • Described the strengths and challenges associated with miRNAs as biomarkers.« less

  16. Added value of cost-utility analysis in simple diagnostic studies of accuracy: (18)F-fluoromethylcholine PET/CT in prostate cancer staging.

    PubMed

    Gerke, Oke; Poulsen, Mads H; Høilund-Carlsen, Poul Flemming

    2015-01-01

    Diagnostic studies of accuracy targeting sensitivity and specificity are commonly done in a paired design in which all modalities are applied in each patient, whereas cost-effectiveness and cost-utility analyses are usually assessed either directly alongside to or indirectly by means of stochastic modeling based on larger randomized controlled trials (RCTs). However the conduct of RCTs is hampered in an environment such as ours, in which technology is rapidly evolving. As such, there is a relatively limited number of RCTs. Therefore, we investigated as to which extent paired diagnostic studies of accuracy can be also used to shed light on economic implications when considering a new diagnostic test. We propose a simple decision tree model-based cost-utility analysis of a diagnostic test when compared to the current standard procedure and exemplify this approach with published data from lymph node staging of prostate cancer. Average procedure costs were taken from the Danish Diagnosis Related Groups Tariff in 2013 and life expectancy was estimated for an ideal 60 year old patient based on prostate cancer stage and prostatectomy or radiation and chemotherapy. Quality-adjusted life-years (QALYs) were deduced from the literature, and an incremental cost-effectiveness ratio (ICER) was used to compare lymph node dissection with respective histopathological examination (reference standard) and (18)F-fluoromethylcholine positron emission tomography/computed tomography (FCH-PET/CT). Lower bounds of sensitivity and specificity of FCH-PET/CT were established at which the replacement of the reference standard by FCH-PET/CT comes with a trade-off between worse effectiveness and lower costs. Compared to the reference standard in a diagnostic accuracy study, any imperfections in accuracy of a diagnostic test imply that replacing the reference standard generates a loss in effectiveness and utility. We conclude that diagnostic studies of accuracy can be put to a more extensive use, over and above a mere indication of sensitivity and specificity of an imaging test, and that health economic considerations should be undertaken when planning a prospective diagnostic accuracy study. These endeavors will prove especially fruitful when comparing several imaging techniques with one another, or the same imaging technique using different tracers, with an independent reference standard for the evaluation of results.

  17. Preliminary evaluation of a gel tube agglutination major cross-match method in dogs.

    PubMed

    Villarnovo, Dania; Burton, Shelley A; Horney, Barbara S; MacKenzie, Allan L; Vanderstichel, Raphaël

    2016-09-01

    A major cross-match gel tube test is available for use in dogs yet has not been clinically evaluated. This study compared cross-match results obtained using the gel tube and the standard tube methods for canine samples. Study 1 included 107 canine sample donor-recipient pairings cross-match tested with the RapidVet-H method gel tube test and compared results with the standard tube method. Additionally, 120 pairings using pooled sera containing anti-canine erythrocyte antibody at various concentrations were tested with leftover blood from a hospital population to assess sensitivity and specificity of the gel tube method in comparison with the standard method. The gel tube method had a good relative specificity of 96.1% in detecting lack of agglutination (compatibility) compared to the standard tube method. Agreement between the 2 methods was moderate. Nine of 107 pairings showed agglutination/incompatibility on either test, too few to allow reliable calculation of relative sensitivity. Fifty percent of the gel tube method results were difficult to interpret due to sample spreading in the reaction and/or negative control tubes. The RapidVet-H method agreed with the standard cross-match method on compatible samples, but detected incompatibility in some sample pairs that were compatible with the standard method. Evaluation using larger numbers of incompatible pairings is needed to assess diagnostic utility. The gel tube method results were difficult to categorize due to sample spreading. Weak agglutination reactions or other factors such as centrifuge model may be responsible. © 2016 American Society for Veterinary Clinical Pathology.

  18. Incremental Validity in the Clinical Assessment of Early Childhood Development

    ERIC Educational Resources Information Center

    Liu, Xin; Zhou, Xiaobin; Lackaff, Julie

    2013-01-01

    The authors demonstrate the increment of clinical validity in early childhood assessment of physical impairment (PI), developmental delay (DD), and autism (AUT) using multiple standardized developmental screening measures such as performance measures and parent and teacher rating scales. Hierarchical regression and sensitivity/specificity analyses…

  19. Monolithic integration of GMR sensors for standard CMOS-IC current sensing

    NASA Astrophysics Data System (ADS)

    De Marcellis, A.; Reig, C.; Cubells-Beltrán, M.-D.; Madrenas, J.; Santos, J. D.; Cardoso, S.; Freitas, P. P.

    2017-09-01

    In this work we report on the development of Giant Magnetoresistive (GMR) sensors for off-line current measurements in standard integrated circuits. An ASIC has been specifically designed and fabricated in the well-known AMS-0.35 μm CMOS technology, including the electronic circuitry for sensor interfacing. It implements an oscillating circuit performing a voltage-to-frequency conversion. Subsequently, a fully CMOS-compatible low temperature post-process has been applied for depositing the GMR sensing devices in a full-bridge configuration onto the buried current straps. Sensitivity and resolution of these sensors have been investigated achieving experimental results that show a detection sensitivity of about 100 Hz/mA, with a resolution of about 5 μA.

  20. Value and impact factors of multidetector computed tomography in diagnosis of preoperative lymph node metastasis in gastric cancer: A PRISMA-compliant systematic review and meta-analysis.

    PubMed

    Luo, Mingxu; Lv, You; Guo, Xiuyu; Song, Hongmei; Su, Guoqiang; Chen, Bo

    2017-08-01

    Multidetector computed tomography (MDCT) exhibited wide ranges of sensitivities and specificities for lymph node assessment of gastric cancer (GC) in several individual studies. This present meta-analysis was carried out to evaluate the value of MDCT in diagnosis of preoperative lymph node metastasis (LNM) and to explore the impact factors that might explain the heterogeneity of its diagnostic accuracy in GC. A comprehensive search was conducted to collect all the relevant studies about the value of MDCT in assessing LNM of GC within the PubMed, Cochrane library and Embase databases up to Feb 2, 2016. Two investigators independently screened the studies, extracted data, and evaluated the quality of included studies. The sensitivity, specificity, and area under ROC curve (AUC) were pooled to estimate the overall accuracy of MDCT. Meta-regression and subgroup analysis were carried out to identify the possible factors influencing the heterogeneity of the accuracy. A total of 27 studies with 6519 subjects were finally included. Overall, the pooled sensitivity, specificity, and AUC were 0.67 (95% CI: 0.56-0.77), 0.86 (95% CI: 0.81-0.90), and 0.86 (95% CI: 0.83-0.89), respectively. Meta-regression revealed that MDCT section thickness, proportion of serosal invasion, and publication year were the main significant impact factors in sensitivity, and MDCT section thickness, multiplanar reformation (MPR), and reference standard were the main significant impact factors in specificity. After the included studies were divided into 2 groups (Group A: studies with proportion of serosa-invasive GC subjects ≥50%; Group B: studies with proportion of serosa-invasive GC subjects <50%), the pooled sensitivity in Group A was significantly higher than in Group B (0.84 [95% CI: 0.75-0.90] vs 0.55 [95% CI: 0.41-0.68], P < .01). For early gastric cancer (EGC), the pooled sensitivity, specificity, and AUC were 0.34 (95% CI: 0.15-0.61), 0.91 (95% CI: 0.84-0.95), and 0.83 (95% CI: 0.80-0.86), respectively. To summarize, MDCT tends to be adequate to assess preoperative LNM in serosa-invasive GC, but insufficient for non-serosa-invasive GC (particularly for EGC) owing to its low sensitivity. Proportion of serosa-invasive GC subjects, MDCT section thickness, MPR, and reference standard are the main factors influencing its diagnostic accuracy.

  1. Use of basal serum or plasma cortisol concentrations to rule out a diagnosis of hypoadrenocorticism in dogs: 123 cases (2000-2005).

    PubMed

    Lennon, Elizabeth M; Boyle, Tonya E; Hutchins, Rae Grace; Friedenthal, Arit; Correa, Maria T; Bissett, Sally A; Moses, Lorra S; Papich, Mark G; Birkenheuer, Adam J

    2007-08-01

    To determine whether basal serum or plasma cortisol concentration can be used as a screening test to rule out hypoadrenocorticism in dogs. Retrospective case-control study. 110 dogs with nonadrenal gland illnesses and 13 dogs with hypoadrenocorticism. Sensitivity and specificity of basal serum or plasma cortisol concentrations of either 2 microg/dL that are not receiving corticosteroids, mitotane, or ketoconazole are highly unlikely to have hypoadrenocorticism. However, if the basal cortisol concentration is

  2. Review-of-systems questionnaire as a predictive tool for psychogenic nonepileptic seizures.

    PubMed

    Robles, Liliana; Chiang, Sharon; Haneef, Zulfi

    2015-04-01

    Patients with refractory epilepsy undergo video-electroencephalography for seizure characterization, among whom approximately 10-30% will be discharged with the diagnosis of psychogenic nonepileptic seizures (PNESs). Clinical PNES predictors have been described but in general are not sensitive or specific. We evaluated whether multiple complaints in a routine review-of-system (ROS) questionnaire could serve as a sensitive and specific marker of PNESs. We performed a retrospective analysis of a standardized ROS questionnaire completed by patients with definite PNESs and epileptic seizures (ESs) diagnosed in our adult epilepsy monitoring unit. A multivariate analysis of covariance (MANCOVA) was used to determine whether groups with PNES and ES differed with respect to the percentage of complaints in the ROS questionnaire. Tenfold cross-validation was used to evaluate the predictive error of a logistic regression classifier for PNES status based on the percentage of positive complaints in the ROS questionnaire. A total of 44 patients were included for analysis. Patients with PNESs had a significantly higher number of complaints in the ROS questionnaire compared to patients with epilepsy. A threshold of 17% positive complaints achieved a 78% specificity and 85% sensitivity for discriminating between PNESs and ESs. We conclude that the routine ROS questionnaire may be a sensitive and specific predictive tool for discriminating between PNESs and ESs. Published by Elsevier Inc.

  3. Comparative diagnostic evaluation of OMP31 gene based TaqMan® real-time PCR assay with visual LAMP assay and indirect ELISA for caprine brucellosis.

    PubMed

    Saini, Suman; Gupta, V K; Gururaj, K; Singh, D D; Pawaiya, R V S; Gangwar, N K; Mishra, A K; Dwivedi, Deepak; Andani, Dimple; Kumar, Ashok; Goswami, T K

    2017-08-01

    Brucellosis is one of the leading causes of abortion in domestic animals that imposes costs on both economy and society. The disease is highly zoonotic and poses risk to animal handlers due to its zoonotic nature. It causes stillbirth, loss of kids and abortion in last term of pregnancy. Reproductive damage includes infertility in does and orchitis and epididymitis in breeding bucks, which result in high financial losses to farmers and the agriculture industry as a whole. It requires highly sensitive and specific assays to diagnose the disease at field level. In the current study, a visual loop-mediated isothermal amplification (LAMP) assay and the TaqMan® real-time PCR were developed with high sensitivity and specificity. For the TaqMan® probe, real-time PCR primers were developed using Omp31 gene as target and primers were designed using discontiguous conserved sequences of Omp31 gene. The Omp31 probes were designed by attaching 6-FAM reporter dye at the 5' end and BHQ-1 quencher at the 3' end. Published primers were used for visual LAMP assay targeting the Omp25 gene. Sensitivity of the standardized visual LAMP assay and TaqMan® real-time PCR assay was determined by serial dilution of positive Brucella melitensis DNA (10 2 to 10 -4  ng) obtained from standard culture. The TaqMan® probe real-time assay can detect as low as 100 fg of B. melitensis DNA, whereas culture from vaginal swab washings has a limit of detection (LOD) of only 1 cfu/ml. Similarly, the visual LAMP assay can detect as low as 10 fg of B. melitensis DNA as compared to an LOD of 30 cfu/ml from culture of vaginal swab washings. Both assays were compared with serological tests (serum tube agglutination test (STAT) and indirect enzyme-linked immunosorbent assay (iELISA)) for diagnostic sensitivity and specificity. Diagnostic sensitivities and specificities for TaqMan® real-time PCR vs. LAMP assays were 98 and 100% vs. 100 and 97.8%, respectively. Results of visual LAMP assay indicated that LAMP is a fast, specific, sensitive, inexpensive and suitable method for diagnosis of B. melitensis infection under field conditions. On the other hand, Omp31 TaqMan® probe real-time assay can be used in conjunction with the other field-based diagnostic tests due to its high specificity.

  4. Sensitivity and Specificity of 50% Excess Weight Loss (50%EWL) and Twelve Other Bariatric Criteria for Weight Loss Success.

    PubMed

    van de Laar, Arnold W; van Rijswijk, A S; Kakar, H; Bruin, S C

    2018-02-27

    Criteria for bariatric weight loss success are numerous. Most of them are arbitrary. None of them is evidence-based. Our objective was to determine their sensitivity and specificity. Thirteen common bariatric weight loss criteria were compared to a benchmark reflecting the gold standard in bariatric surgery. We used an elaborate baseline BMI-independent weight loss percentile chart, based on retrospective data after laparoscopic Roux-en-Y gastric bypass (LRYGB), performed between 2007 and 2017. Percentile curves p31.6 (patients' expectation), p25 (interquartile range), p15.9 (1 standard deviation (SD) below median), and p10.9 (surgeons' goal) were used as possible cutoff for success to determine true or false positive and negative results beyond 1 year. We operated 4497 primary LRYGB patients, with mean follow-up 22 (± 1 SD 19; range 0-109) months, 3031 patients with last result ≥ 1 year, 518 ≥ 5 years. For all four cutoff percentile curves for success, specificities were low (2-72%) for criteria < 35 body mass index (BMI), ≥ 25percentage excess BMI loss (%EBMIL), ≥ 50%EBMIL, ≥ 15 percentage total weight loss (%TWL), ≥ 20%TWL, ≥ 25 percentage excess weight loss (%EWL), and high (83-96%) for < 30 BMI. No criterion had > 80% specificity and sensitivity for a cutoff above p15.9. For p15.9, they were both > 80% for criteria ≥ 10 BMI reduction and ≥ 50%EWL, both > 90% for ≥ 25%TWL and ≥ 35 percentage alterable weight loss (%AWL). All criteria had high sensitivities for all cutoff percentile curves (87-100%), except < 30 BMI (65-78%). For the first time, common bariatric criteria for weight loss success were systematically validated. Most criteria recognized success very well (high sensitivities), but ≥ 15%TWL, ≥ 20%TWL, < 35BMI, ≥ 25%EWL, ≥ 25%EBMIL, and ≥ 50%EBMIL left too many poor responders unnoticed (low specificities). Bariatric weight loss success is best assessed by comparing results to percentile curve 1 SD below median (p15.9) in a bariatric baseline BMI-independent weight loss percentile chart. Criteria ≥ 35%AWL and ≥ 25%TWL came close to that curve, both with > 90% sensitivity and specificity. Among others, criterion ≥ 50%EBMIL did not.

  5. Combination of the non-invasive tests for the diagnosis of endometriosis.

    PubMed

    Nisenblat, Vicki; Prentice, Lucy; Bossuyt, Patrick M M; Farquhar, Cindy; Hull, M Louise; Johnson, Neil

    2016-07-13

    About 10% of women of reproductive age suffer from endometriosis, a costly chronic disease causing pelvic pain and subfertility. Laparoscopy is the gold standard diagnostic test for endometriosis, but is expensive and carries surgical risks. Currently, there are no non-invasive tests available in clinical practice to accurately diagnose endometriosis. This review assessed the diagnostic accuracy of combinations of different non-invasive testing modalities for endometriosis and provided a summary of all the reviews in the non-invasive tests for endometriosis series. To estimate the diagnostic accuracy of any combination of non-invasive tests for the diagnosis of pelvic endometriosis (peritoneal and/or ovarian or deep infiltrating) compared to surgical diagnosis as a reference standard. The combined tests were evaluated as replacement tests for diagnostic surgery and triage tests to assist decision-making to undertake diagnostic surgery for endometriosis. We did not restrict the searches to particular study designs, language or publication dates. We searched CENTRAL to July 2015, MEDLINE and EMBASE to May 2015, as well as the following databases to April 2015: CINAHL, PsycINFO, Web of Science, LILACS, OAIster, TRIP, ClinicalTrials.gov, DARE and PubMed. We considered published, peer-reviewed, randomised controlled or cross-sectional studies of any size, including prospectively collected samples from any population of women of reproductive age suspected of having one or more of the following target conditions: ovarian, peritoneal or deep infiltrating endometriosis (DIE). We included studies comparing the diagnostic test accuracy of a combination of several testing modalities with the findings of surgical visualisation of endometriotic lesions. Three review authors independently collected and performed a quality assessment of the data from each study by using the QUADAS-2 tool. For each test, the data were classified as positive or negative for the surgical detection of endometriosis and sensitivity and specificity estimates were calculated. The bivariate model was planned to obtain pooled estimates of sensitivity and specificity whenever sufficient data were available. The predetermined criteria for a clinically useful test to replace diagnostic surgery were a sensitivity of 0.94 and a specificity of 0.79 to detect endometriosis. We set the criteria for triage tests at a sensitivity of 0.95 and above and a specificity of 0.50 and above, which 'rules out' the diagnosis with high accuracy if there is a negative test result (SnOUT test), or a sensitivity of 0.50 and above and a specificity of 0.95 and above, which 'rules in' the diagnosis with high accuracy if there is a positive result (SpIN test). Eleven eligible studies included 1339 participants. All the studies were of poor methodological quality. Seven studies evaluated pelvic endometriosis, one study considered DIE and/or ovarian endometrioma, two studies differentiated endometrioma from other ovarian cysts and one study addressed mapping DIE at specific anatomical sites. Fifteen different diagnostic combinations were assessed, including blood, urinary or endometrial biomarkers, transvaginal ultrasound (TVUS) and clinical history or examination. We did not pool estimates of sensitivity and specificity, as each study analysed independent combinations of the non-invasive tests.Tests that met the criteria for a replacement test were: a combination of serum IL-6 (cut-off >15.4 pg/ml) and endometrial PGP 9.5 for pelvic endometriosis (sensitivity 1.00 (95% confidence interval (CI) 0.91 to 1.00), specificity 0.93 (95% CI, 0.80, 0.98) and the combination of vaginal examination and transvaginal ultrasound (TVUS) for rectal endometriosis (sensitivity 0.96 (95% CI 0.86 to 0.99), specificity 0.98 (95% CI 0.94 to 1.00)). Tests that met the criteria for SpIN triage tests for pelvic endometriosis were: 1. a multiplication of urine vitamin-D-binding protein (VDBP) and serum CA-125 (cut-off >2755) (sensitivity 0.74 (95% CI 0.60 to 0.84), specificity 0.97 (95% CI 0.86 to 1.00)) and 2. a combination of history (length of menses), serum CA-125 (cut-off >35 U/ml) and endometrial leukocytes (sensitivity 0.61 (95% CI 0.54 to 0.69), specificity 0.95 (95% CI 0.91 to 0.98)). For endometrioma, the following combinations qualified as SpIN test: 1. TVUS and either serum CA-125 (cut-off ≥25 U/ml) or CA 19.9 (cut-off ≥12 U/ml) (sensitivity 0.79 (95% CI 0.64 to 0.91), specificity 0.97 (95% CI 0.91 to 1.00)); 2. TVUS and serum CA 19.9 (cut-off ≥12 U/ml) (sensitivity 0.54 (95% CI 0.37 to 0.70), specificity 0.97 (95% CI 0.91 to 1.0)); 3-4. TVUS and serum CA-125 (cut-off ≥20 U/ml or cut-off ≥25 U/ml) (sensitivity 0.69 (95% CI 0.49 to 0.85), specificity 0.96 (95% CI 0.88 to 0.99)); 5. TVUS and serum CA-125 (cut-off ≥35 U/ml) (sensitivity 0.52 (95% CI 0.33 to 0.71), specificity 0.97 (95% CI 0.90 to 1.00)). A combination of vaginal examination and TVUS reached the threshold for a SpIN test for obliterated pouch of Douglas (sensitivity 0.87 (95% CI 0.69 to 0.96), specificity 0.98 (95% CI 0.95 to 1.00)), vaginal wall endometriosis (sensitivity 0.82 (95% CI 0.60 to 0.95), specificity 0.99 (95% CI 0.97 to 1.0)) and rectovaginal septum endometriosis (sensitivity 0.88 (95% CI 0.47 to 1.00), specificity 0.99 (95% CI 0.96 to 1.00)).All the tests were evaluated in individual studies and displayed wide CIs. Due to the heterogeneity and high risk of bias of the included studies, the clinical utility of the studied combination diagnostic tests for endometriosis remains unclear. None of the biomarkers evaluated in this review could be evaluated in a meaningful way and there was insufficient or poor-quality evidence. Laparoscopy remains the gold standard for the diagnosis of endometriosis and using any non-invasive tests should only be undertaken in a research setting.

  6. A model independent search for new physics in final states containing leptons at the DO experiment

    NASA Astrophysics Data System (ADS)

    Piper, Joel M.

    The standard model is known to be the low energy limit of a more general theory. Several consequences of the standard model point to a strong probability of new physics becoming experimentally visible in high energy collisions of a few TeV, resulting in high momentum objects. The specific signatures of these collisions are topics of much debate. Rather than choosing a specific signature, this analysis broadly searches the data, preferring breadth over sensitivity. In searching for new physics, several different approaches are used. These include the comparison of data with standard model background expectation in overall number of events, comparisons of distributions of many kinematic variables, and finally comparisons on the tails of distributions that sum the momenta of the objects in an event. With 1.07 fb-1 at the DO experiment, we find no evidence of physics beyond the standard model. Several discrepancies from the standard model were found, but none of these provide a compelling case for new physics.

  7. Clinical evaluation and validation of laboratory methods for the diagnosis of Bordetella pertussis infection: Culture, polymerase chain reaction (PCR) and anti-pertussis toxin IgG serology (IgG-PT)

    PubMed Central

    Cassiday, Pamela K.; Pawloski, Lucia C.; Tatti, Kathleen M.; Martin, Monte D.; Briere, Elizabeth C.; Tondella, M. Lucia; Martin, Stacey W.

    2018-01-01

    Introduction The appropriate use of clinically accurate diagnostic tests is essential for the detection of pertussis, a poorly controlled vaccine-preventable disease. The purpose of this study was to estimate the sensitivity and specificity of different diagnostic criteria including culture, multi-target polymerase chain reaction (PCR), anti-pertussis toxin IgG (IgG-PT) serology, and the use of a clinical case definition. An additional objective was to describe the optimal timing of specimen collection for the various tests. Methods Clinical specimens were collected from patients with cough illness at seven locations across the United States between 2007 and 2011. Nasopharyngeal and blood specimens were collected from each patient during the enrollment visit. Patients who had been coughing for ≤ 2 weeks were asked to return in 2–4 weeks for collection of a second, convalescent blood specimen. Sensitivity and specificity of each diagnostic test were estimated using three methods—pertussis culture as the “gold standard,” composite reference standard analysis (CRS), and latent class analysis (LCA). Results Overall, 868 patients were enrolled and 13.6% were B. pertussis positive by at least one diagnostic test. In a sample of 545 participants with non-missing data on all four diagnostic criteria, culture was 64.0% sensitive, PCR was 90.6% sensitive, and both were 100% specific by LCA. CRS and LCA methods increased the sensitivity estimates for convalescent serology and the clinical case definition over the culture-based estimates. Culture and PCR were most sensitive when performed during the first two weeks of cough; serology was optimally sensitive after the second week of cough. Conclusions Timing of specimen collection in relation to onset of illness should be considered when ordering diagnostic tests for pertussis. Consideration should be given to including IgG-PT serology as a confirmatory test in the Council of State and Territorial Epidemiologists (CSTE) case definition for pertussis. PMID:29652945

  8. Comparison of five diagnostic tests for Giardia duodenalis in fecal samples from young dogs.

    PubMed

    Uehlinger, Fabienne D; Naqvi, S Ali; Greenwood, Spencer J; McClure, J Trenton; Conboy, Gary; O'Handley, Ryan; Barkema, Herman W

    2017-09-15

    Five diagnostic tests were compared for the diagnosis of Giardia duodenalis in fecal samples of young dogs. Fecal samples were collected from 136 healthy dogs <1year old and examined using immunofluorescence antibody microscopy (IFA) after sucrose gradient centrifugation, zinc sulfate centrifugal flotation technique (ZSCT), SNAP ® Giardia test, and ProSpecT ® Giardia EZ Microplate assay. In addition, polymerase chain reaction (PCR) of the 16S rRNA gene was performed. Kappa (κ) statistic was calculated to assess diagnostic agreement between the IFA and each test. Using the IFA as the gold standard, the relative sensitivity and specificity of each test were determined. Subsequently, a Bayesian approach was used to estimate the sensitivity and specificity of each test in comparison to the IFA results. Giardia duodenalis was detected in 41% of the samples examined by IFA. The ZSCT resulted in 37% of positive samples, with a relative sensitivity and specificity of 86 and 98%, respectively. The SNAP ® Giardia test was positive in 40% of the samples, with a relative sensitivity and specificity of 91 and 96%, respectively. The ProSpecT ® test was positive in 51% of the samples, with a relative sensitivity and specificity of 100 and 83%, respectively. The relative sensitivity and specificity for PCR were 58 and 56%, respectively, with 55% of samples being PCR-positive. While the sensitivity and specificity estimates of each test in comparison to the IFA changed when using a Bayesian approach, the conclusions remained the same. While the ProSpecT ® test was the most sensitive test in this study, it is not designed for dogs and more costly than the other tests. The SNAP ® Giardia test performed similar to the ZSCT but may be more favorable because it is fast and easy to perform. Performance of the PCR was poor and the benefit of PCR may be in determining genotypes for evaluating zoonotic transfer between dogs and humans. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Inspection system qualification and integration into the mask manufacturing environment

    NASA Astrophysics Data System (ADS)

    LaVoy, Rosanne; Fujioka, Ron

    1995-12-01

    Integration of a mask inspection system into a manufacturing environment poses new challenges to both the inspection engineer and the equipment supplier. Traditional specifications (limited primarily to sensitivity and uptime) are no longer sufficient to successfully integrate a system into a 7 by 24 manufacturing area with multiple systems. Issues such as system sensitivity matching, sensitivity characterization by defect type, operator training and certification standards, and real-time SPC control of the systems must be addressed. This paper outlines some of the techniques Intel Mask Operation uses for integration of a new inspection system into the manufacturing line. Specifically moving a beta- site type tool out of the beta-site mode and into volume production. Examples are presented, including installation for manufacturing (including ergonomic modifications), techniques for system-to-system matching, use of SPC charts to monitor system performance, and operator training/certifications. Relationships between system PMs, or other environmental changes, and the system sensitivity SPC control charts also are discussed.

  10. Comparison of the Gen-Probe Aptima HIV-1 and Abbott HIV-1 qualitative assays with the Roche Amplicor HIV-1 DNA assay for early infant diagnosis using dried blood spots.

    PubMed

    Nelson, Julie A E; Hawkins, J Tyler; Schanz, Maria; Mollan, Katie; Miller, Melissa B; Schmitz, John L; Fiscus, Susan A

    2014-08-01

    The current gold standard for infant diagnosis of HIV-1 is the Roche Amplicor Qualitative DNA assay, but it is being phased out. Compare the Abbott qualitative assay and the Gen-Probe Aptima assay to the gold standard Roche DNA assay using dried blood spots (DBS). The Gen-Probe Aptima and Abbott qualitative HIV-1 assays were compared to the Roche DNA assay for early infant diagnosis. Specificity and sensitivity were determined for the three assays using DBS from 50 HIV-exposed uninfected infants and 269 HIV-1 infected adults from North Carolina, respectively. All of the negative and 151 of the positive DBS had valid results on the 3 different assays, and an additional 118 positive DBS had valid results on the Roche DNA and Aptima assays. All three assays were very specific. The Roche DNA assay was the most sensitive (96.7%) over a wide range of HIV PVL, including samples with PVL<400 copies/ml. Restricted to samples with PVL>400 copies/ml, the Gen-Probe Aptima assay had sensitivity (96.5%) comparable to the Roche DNA assay (98.8%). The Abbott Qualitative assay was the least sensitive and only had sensitivity above 95% among samples with PVL over 1000 copies/ml. The Abbott HIV-1 Qualitative assay was not as sensitive as the comparator assays, so it would not be a useful replacement assay, especially for infants taking antiretroviral prophylaxis. The Gen-Probe Aptima assay is an adequate replacement option for infant diagnosis using DBS. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Evaluation of a real-time polymerase chain reaction assay of the outer membrane protein P2 gene for the detection of Haemophilus parasuis in clinical samples.

    PubMed

    McDowall, Rebeccah; Slavic, Durda; MacInnes, Janet I; Cai, Hugh Y

    2014-04-01

    A real-time polymerase chain reaction (PCR) assay of the outer membrane protein (OMP) P2 gene was developed and used to test 97 putative Haemophilus parasuis pure cultures and 175 clinical tissue samples. With standard culture isolation as the gold standard, the diagnostic sensitivity and specificity of the PCR assay were determined to be 83% and 80%, respectively.

  12. Evaluation of a real-time polymerase chain reaction assay of the outer membrane protein P2 gene for the detection of Haemophilus parasuis in clinical samples

    PubMed Central

    McDowall, Rebeccah; Slavic, Durda; MacInnes, Janet I.; Cai, Hugh Y.

    2014-01-01

    A real-time polymerase chain reaction (PCR) assay of the outer membrane protein (OMP) P2 gene was developed and used to test 97 putative Haemophilus parasuis pure cultures and 175 clinical tissue samples. With standard culture isolation as the gold standard, the diagnostic sensitivity and specificity of the PCR assay were determined to be 83% and 80%, respectively. PMID:24688178

  13. Aminopenicillin-associated exanthem: lymphocyte transformation testing revisited.

    PubMed

    Trautmann, A; Seitz, C S; Stoevesandt, J; Kerstan, A

    2014-12-01

    The lymphocyte transformation test (LTT) has been promoted as in-vitro test for diagnosis of drug hypersensitivity. For determination of statistical LTT sensitivity, series of patients with clinically uniform reactions followed by complete drug hypersensitivity work-up are mandatory. Assessment of LTT specificity requires control patients who tolerated exposure to the drug studied. To prospectively determine the diagnostic value of the LTT in a clinically and diagnostically well-defined series of patients. Patients with exanthematous skin eruptions after ampicillin (AMP) intake were included in this study. After exclusion or confirmation of delayed-onset allergic AMP hypersensitivity by skin and provocation testing, two independent LTTs were performed: one standard LTT and a modified LTT with additional anti-CD3/anti-CD28 monoclonal antibody stimulation. By testing, delayed-onset allergic AMP hypersensitivity was diagnosed in 11 patients and definitely ruled out in 26. The standard LTT reached a diagnostic sensitivity of 54.5% while the modified LTT yielded 72.7%. However, the methodical test modification resulted in a decline of specificity from 92.3% (standard LTT) to 76.9%. In cases of AMP-associated exanthems, the diagnostic value of the LTT compared with routine allergy testing is limited. When evaluating such exanthems, provocation testing remains the gold standard. Delayed reading of intradermal skin tests remains most useful to avoid positive provocation reactions. © 2014 John Wiley & Sons Ltd.

  14. NEMA NU 4-2008 Comparison of Preclinical PET Imaging Systems

    PubMed Central

    Goertzen, Andrew L.; Bao, Qinan; Bergeron, Mélanie; Blankemeyer, Eric; Blinder, Stephan; Cañadas, Mario; Chatziioannou, Arion F.; Dinelle, Katherine; Elhami, Esmat; Jans, Hans-Sonke; Lage, Eduardo; Lecomte, Roger; Sossi, Vesna; Surti, Suleman; Tai, Yuan-Chuan; Vaquero, Juan José; Vicente, Esther; Williams, Darin A.; Laforest, Richard

    2014-01-01

    The National Electrical Manufacturers Association (NEMA) standard NU 4-2008 for performance measurements of small-animal tomographs was recently published. Before this standard, there were no standard testing procedures for preclinical PET systems, and manufacturers could not provide clear specifications similar to those available for clinical systems under NEMA NU 2-1994 and 2-2001. Consequently, performance evaluation papers used methods that were modified ad hoc from the clinical PET NEMA standard, thus making comparisons between systems difficult. Methods We acquired NEMA NU 4-2008 performance data for a collection of commercial animal PET systems manufactured since 2000: micro- PET P4, microPET R4, microPET Focus 120, microPET Focus 220, Inveon, ClearPET, Mosaic HP, Argus (formerly eXplore Vista), VrPET, LabPET 8, and LabPET 12. The data included spatial resolution, counting-rate performance, scatter fraction, sensitivity, and image quality and were acquired using settings for routine PET. Results The data showed a steady improvement in system performance for newer systems as compared with first-generation systems, with notable improvements in spatial resolution and sensitivity. Conclusion Variation in system design makes direct comparisons between systems from different vendors difficult. When considering the results from NEMA testing, one must also consider the suitability of the PET system for the specific imaging task at hand. PMID:22699999

  15. A highly sensitive search strategy for clinical trials in Literatura Latino Americana e do Caribe em Ciências da Saúde (LILACS) was developed.

    PubMed

    Manríquez, Juan J

    2008-04-01

    Systematic reviews should include as many articles as possible. However, many systematic reviews use only databases with high English language content as sources of trials. Literatura Latino Americana e do Caribe em Ciências da Saúde (LILACS) is an underused source of trials, and there is not a validated strategy for searching clinical trials to be used in this database. The objective of this study was to develop a sensitive search strategy for clinical trials in LILACS. An analytical survey was performed. Several single and multiple-term search strategies were tested for their ability to retrieve clinical trials in LILACS. Sensitivity, specificity, and accuracy of each single and multiple-term strategy were calculated using the results of a hand-search of 44 Chilean journals as gold standard. After combining the most sensitive, specific, and accurate single and multiple-term search strategy, a strategy with a sensitivity of 97.75% (95% confidence interval [CI]=95.98-99.53) and a specificity of 61.85 (95% CI=61.19-62.51) was obtained. LILACS is a source of trials that could improve systematic reviews. A new highly sensitive search strategy for clinical trials in LILACS has been developed. It is hoped this search strategy will improve and increase the utilization of LILACS in future systematic reviews.

  16. Clinical significance of preoperative imaging in oral squamous cell carcinoma compared with lymph node status: a comparative retrospective study.

    PubMed

    Mazzawi, Elias; El-Naaj, Imad Abu; Ghantous, Yasmine; Balan, Salim; Sabo, Edmond; Rachmiel, Adi; Leiser, Yoav

    2018-05-01

    The accuracy and sensitivity of commonly used imaging modalities in evaluating oral cavity cancer was evaluated by comparing the preoperative radiologic findings and the postoperative pathology report. Patients with oral squamous cell carcinoma, who had undergone at least 1 imaging test 2 weeks before surgery were included. Radiologic findings were compared with the dissected neck findings to assess the lymph node status. Sensitivity and specificity of the imaging modalities were calculated by using the χ 2 test. Sensitivities for detecting metastatic neck lymph nodes at a threshold of 1 cm were 48% (P = .02) and 43.8% (P = .3) for computed tomography (CT) and magnetic resonance imaging respectively. Specificities were 76.3% and 70%, respectively. As for the 1.5 cm threshold, sensitivities were 36% (P = .002) and 31.3% (P = .5), respectively, and specificities were 91.5% and 76.7%, respectively. PET-CT was the most sensitive modality in the present study, with a P value of .02. The different studied imaging modalities used for preoperative neck staging are not sensitive enough and would lead to underdiagnoses of a significant proportion of patients. Thus, prophylactic neck dissection for occult neck disease is of extreme importance and remains the gold standard for oral cancer treatment. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Nano-flow vs standard-flow: Which is the more suitable LC/MS method for quantifying hepcidin-25 in human serum in routine clinical settings?

    PubMed

    Vialaret, Jérôme; Picas, Alexia; Delaby, Constance; Bros, Pauline; Lehmann, Sylvain; Hirtz, Christophe

    2018-06-01

    Hepcidin-25 peptide is a biomarker which is known to have considerable clinical potential for diagnosing iron-related diseases. Developing analytical methods for the absolute quantification of hepcidin is still a real challenge, however, due to the sensitivity, specificity and reproducibility issues involved. In this study, we compare and discuss two MS-based assays for quantifying hepcidin, which differ only in terms of the type of liquid chromatography (nano LC/MS versus standard LC/MS) involved. The same sample preparation, the same internal standards and the same MS analyzer were used with both approaches. In the field of proteomics, nano LC chromatography is generally known to be more sensitive and less robust than standard LC methods. In this study, we established that the performances of the standard LC method are equivalent to those of our previously developed nano LC method. Although the analytical performances were very similar in both cases. The standard-flow platform therefore provides the more suitable alternative for accurately determining hepcidin in clinical settings. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Airway physical examination tests for detection of difficult airway management in apparently normal adult patients.

    PubMed

    Roth, Dominik; Pace, Nathan L; Lee, Anna; Hovhannisyan, Karen; Warenits, Alexandra-Maria; Arrich, Jasmin; Herkner, Harald

    2018-05-15

    The unanticipated difficult airway is a potentially life-threatening event during anaesthesia or acute conditions. An unsuccessfully managed upper airway is associated with serious morbidity and mortality. Several bedside screening tests are used in clinical practice to identify those at high risk of difficult airway. Their accuracy and benefit however, remains unclear. The objective of this review was to characterize and compare the diagnostic accuracy of the Mallampati classification and other commonly used airway examination tests for assessing the physical status of the airway in adult patients with no apparent anatomical airway abnormalities. We performed this individually for each of the four descriptors of the difficult airway: difficult face mask ventilation, difficult laryngoscopy, difficult tracheal intubation, and failed intubation. We searched major electronic databases including CENTRAL, MEDLINE, Embase, ISI Web of Science, CINAHL, as well as regional, subject specific, and dissertation and theses databases from inception to 16 December 2016, without language restrictions. In addition, we searched the Science Citation Index and checked the references of all the relevant studies. We also handsearched selected journals, conference proceedings, and relevant guidelines. We updated this search in March 2018, but we have not yet incorporated these results. We considered full-text diagnostic test accuracy studies of any individual index test, or a combination of tests, against a reference standard. Participants were adults without obvious airway abnormalities, who were having laryngoscopy performed with a standard laryngoscope and the trachea intubated with a standard tracheal tube. Index tests included the Mallampati test, modified Mallampati test, Wilson risk score, thyromental distance, sternomental distance, mouth opening test, upper lip bite test, or any combination of these. The target condition was difficult airway, with one of the following reference standards: difficult face mask ventilation, difficult laryngoscopy, difficult tracheal intubation, and failed intubation. We performed screening and selection of the studies, data extraction and assessment of methodological quality (using QUADAS-2) independently and in duplicate. We designed a Microsoft Access database for data collection and used Review Manager 5 and R for data analysis. For each index test and each reference standard, we assessed sensitivity and specificity. We produced forest plots and summary receiver operating characteristic (ROC) plots to summarize the data. Where possible, we performed meta-analyses to calculate pooled estimates and compare test accuracy indirectly using bivariate models. We investigated heterogeneity and performed sensitivity analyses. We included 133 (127 cohort type and 6 case-control) studies involving 844,206 participants. We evaluated a total of seven different prespecified index tests in the 133 studies, as well as 69 non-prespecified, and 32 combinations. For the prespecified index tests, we found six studies for the Mallampati test, 105 for the modified Mallampati test, six for the Wilson risk score, 52 for thyromental distance, 18 for sternomental distance, 34 for the mouth opening test, and 30 for the upper lip bite test. Difficult face mask ventilation was the reference standard in seven studies, difficult laryngoscopy in 92 studies, difficult tracheal intubation in 50 studies, and failed intubation in two studies. Across all studies, we judged the risk of bias to be variable for the different domains; we mostly observed low risk of bias for patient selection, flow and timing, and unclear risk of bias for reference standard and index test. Applicability concerns were generally low for all domains. For difficult laryngoscopy, the summary sensitivity ranged from 0.22 (95% confidence interval (CI) 0.13 to 0.33; mouth opening test) to 0.67 (95% CI 0.45 to 0.83; upper lip bite test) and the summary specificity ranged from 0.80 (95% CI 0.74 to 0.85; modified Mallampati test) to 0.95 (95% CI 0.88 to 0.98; Wilson risk score). The upper lip bite test for diagnosing difficult laryngoscopy provided the highest sensitivity compared to the other tests (P < 0.001). For difficult tracheal intubation, summary sensitivity ranged from 0.24 (95% CI 0.12 to 0.43; thyromental distance) to 0.51 (95% CI 0.40 to 0.61; modified Mallampati test) and the summary specificity ranged from 0.87 (95% CI 0.82 to 0.91; modified Mallampati test) to 0.93 (0.87 to 0.96; mouth opening test). The modified Mallampati test had the highest sensitivity for diagnosing difficult tracheal intubation compared to the other tests (P < 0.001). For difficult face mask ventilation, we could only estimate summary sensitivity (0.17, 95% CI 0.06 to 0.39) and specificity (0.90, 95% CI 0.81 to 0.95) for the modified Mallampati test. Bedside airway examination tests, for assessing the physical status of the airway in adults with no apparent anatomical airway abnormalities, are designed as screening tests. Screening tests are expected to have high sensitivities. We found that all investigated index tests had relatively low sensitivities with high variability. In contrast, specificities were consistently and markedly higher than sensitivities across all tests. The standard bedside airway examination tests should be interpreted with caution, as they do not appear to be good screening tests. Among the tests we examined, the upper lip bite test showed the most favourable diagnostic test accuracy properties. Given the paucity of available data, future research is needed to develop tests with high sensitivities to make them useful, and to consider their use for screening difficult face mask ventilation and failed intubation. The 27 studies in 'Studies awaiting classification' may alter the conclusions of the review, once we have assessed them.

  19. A systematic review of the sensitivity and specificity of the toe-brachial index for detecting peripheral artery disease.

    PubMed

    Tehan, Peta Ellen; Santos, Derek; Chuter, Vivienne Helaine

    2016-08-01

    The toe-brachial index (TBI) is used as an adjunct to the ankle-brachial index (ABI) for non-invasive lower limb vascular screening. With increasing evidence suggesting limitations of the ABI for diagnosis of vascular complications, particularly in specific populations including diabetes cohorts, the TBI is being used more widely. The aim of this review was to determine the sensitivity and specificity of the TBI for detecting peripheral artery disease (PAD) in populations at risk of this disease. A database search was conducted to identify current work relating to the sensitivity and specificity of toe-brachial indices up to July 2015. Only studies using valid diagnostic imaging as a reference standard were included. The QUADAS-2 tool was used to critically appraise included articles. Seven studies met the inclusion criteria. Sensitivity of the TBI for PAD was reported in all seven studies and ranged from 45% to 100%; specificity was reported by five studies only and ranged from 16% to 100%. In conclusion, this review suggests that the TBI has variable diagnostic accuracy for the presence of PAD in specific populations at risk of developing the disease. There was a notable lack of large-scale diagnostic accuracy studies determining the diagnostic accuracy of the TBI in detecting PAD in different at-risk cohorts. However, standardised normal values need to be established for the TBI to conclusively determine the diagnostic accuracy of this test. © The Author(s) 2016.

  20. Aptima HIV-1 Quant Dx--A fully automated assay for both diagnosis and quantification of HIV-1.

    PubMed

    Nair, Sangeetha Vijaysri; Kim, Hee Cheol; Fortunko, Jacqueline; Foote, Tracy; Peling, Tashi; Tran, Cuong; Nugent, Charles Thomas; Joo, Sunghae; Kang, Youna; Wilkins, Bana; Lednovich, Kristen; Worlock, Andrew

    2016-04-01

    Separate assays are available for diagnosis and viral load (VL) monitoring of HIV-1. Studies have shown that using a single test for both confirmatory diagnosis and VL increases linkage to care. To validate a single assay for both diagnosis and VL monitoring of HIV-1 on the fully automated Panther platform. Validate the assay by assessing specificity, sensitivity, subtype detection, seroconversion, reproducibility and linearity. Also assess diagnostic agreement with the Procleix(®) Ultrio Elite™ discriminatory assay (Procleix), and agreement of VL results (method comparison) with Ampliprep/COBAS TaqMan HIV-1 version 2.0 (CAP/CTM), using clinical samples. The assay was specific (100%) and sensitive with a 95% limit of detection of 12 copies/mL with the 3rd WHO standards. Aptima detected HIV in seroconversion panels 6 and 11 days before p24 antigen and antibody tests, respectively. Diagnostic agreement with Procleix, was 100%. Regression analysis showed good agreement of VL results between Aptima and CAP/CTM with a slope of 1.02, intercept of 0.07, and correlation coefficient (R(2)) of 0.97. Aptima was more sensitive than CAP/CTM. Equivalent quantification was seen on testing clinical samples and isolates belonging to HIV group M, N, O and P and commercially available subtype panels. Assay results were linear (R(2) 0.9994) with standard deviation of <0.17 log copies across assay range. The good specificity, sensitivity, precision, subtype performance and clinical agreement with other assays demonstrated by Aptima combined with the complete automation provided by the Panther platform makes Aptima a good candidate for both VL monitoring and diagnosis of HIV-1. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  1. Study on ABO and RhD blood grouping: Comparison between conventional tile method and a new solid phase method (InTec Blood Grouping Test Kit).

    PubMed

    Yousuf, R; Abdul Ghani, S A; Abdul Khalid, N; Leong, C F

    2018-04-01

    'InTec Blood Grouping Test kit' using solid-phase technology is a new method which may be used at outdoor blood donation site or at bed side as an alternative to the conventional tile method in view of its stability at room temperature and fulfilled the criteria as point of care test. This study aimed to compare the efficiency of this solid phase method (InTec Blood Grouping Test Kit) with the conventional tile method in determining the ABO and RhD blood group of healthy donors. A total of 760 voluntary donors who attended the Blood Bank, Penang Hospital or offsite blood donation campaigns from April to May 2014 were recruited. The ABO and RhD blood groups were determined by the conventional tile method and the solid phase method, in which the tube method was used as the gold standard. For ABO blood grouping, the tile method has shown 100% concordance results with the gold standard tube method, whereas the solid-phase method only showed concordance result for 754/760 samples (99.2%). Therefore, for ABO grouping, tile method has 100% sensitivity and specificity while the solid phase method has slightly lower sensitivity of 97.7% but both with good specificity of 100%. For RhD grouping, both the tile and solid phase methods have grouped one RhD positive specimen as negative each, thus giving the sensitivity and specificity of 99.9% and 100% for both methods respectively. The 'InTec Blood Grouping Test Kit' is suitable for offsite usage because of its simplicity and user friendliness. However, further improvement in adding the internal quality control may increase the test sensitivity and validity of the test results.

  2. Assessment of statistic analysis in non-radioisotopic local lymph node assay (non-RI-LLNA) with alpha-hexylcinnamic aldehyde as an example.

    PubMed

    Takeyoshi, Masahiro; Sawaki, Masakuni; Yamasaki, Kanji; Kimber, Ian

    2003-09-30

    The murine local lymph node assay (LLNA) is used for the identification of chemicals that have the potential to cause skin sensitization. However, it requires specific facility and handling procedures to accommodate a radioisotopic (RI) endpoint. We have developed non-radioisotopic (non-RI) endpoint of LLNA based on BrdU incorporation to avoid a use of RI. Although this alternative method appears viable in principle, it is somewhat less sensitive than the standard assay. In this study, we report investigations to determine the use of statistical analysis to improve the sensitivity of a non-RI LLNA procedure with alpha-hexylcinnamic aldehyde (HCA) in two separate experiments. Consequently, the alternative non-RI method required HCA concentrations of greater than 25% to elicit a positive response based on the criterion for classification as a skin sensitizer in the standard LLNA. Nevertheless, dose responses to HCA in the alternative method were consistent in both experiments and we examined whether the use of an endpoint based upon the statistical significance of induced changes in LNC turnover, rather than an SI of 3 or greater, might provide for additional sensitivity. The results reported here demonstrate that with HCA at least significant responses were, in each of two experiments, recorded following exposure of mice to 25% of HCA. These data suggest that this approach may be more satisfactory-at least when BrdU incorporation is measured. However, this modification of the LLNA is rather less sensitive than the standard method if employing statistical endpoint. Taken together the data reported here suggest that a modified LLNA in which BrdU is used in place of radioisotope incorporation shows some promise, but that in its present form, even with the use of a statistical endpoint, lacks some of the sensitivity of the standard method. The challenge is to develop strategies for further refinement of this approach.

  3. Adaptation by Design: A Context-Sensitive, Dialogic Approach to Interventions

    ERIC Educational Resources Information Center

    Kirshner, Ben; Polman, Joseph L.

    2013-01-01

    Applied researchers, whether working with the framework of design-based research or intervention science, face a similar implementation challenge: practitioners who enact their programs typically do so in varied, context-specific ways. Although this variability is often seen as a problem for those who privilege fidelity and standardization, we…

  4. Comparison of fecal DNA extraction kits for the detection of Mycobacterium avium subsp. paratuberculosis

    USDA-ARS?s Scientific Manuscript database

    Fecal culture is considered the gold standard for the diagnostics of paratuberculosis, however, PCR for the detection of Mycobacterium avium subsp. paratuberculosis (MAP) in fecal material is widely used today, having demonstrated great sensitivity and specificity. To insure the most efficient and r...

  5. Comparison of fecal DNA extraction kits for the detection of Mycobacterium avium subsp. paratuberculosis

    USDA-ARS?s Scientific Manuscript database

    Fecal culture is considered the gold standard for the diagnosis of paratuberculosis, however, PCR for the detection of Mycobacterium avium subsp. paratuberculosis (MAP) in fecal material is widely used today, having demonstrated great sensitivity and specificity. To insure the most efficient and rep...

  6. ASCA Ethical Standards and the Relevance of Eastern Ethical Theories

    ERIC Educational Resources Information Center

    Cook, Amy L.; Houser, Rick A.

    2009-01-01

    As schools become increasingly diverse through immigration and growth of minority groups, it is important that school counselors incorporate culturally sensitive ethical decision-making in their practice. The use of Western ethical theories in the application of professional codes of ethics provides a specific perspective in ethical…

  7. Radiation treatment of pharmaceuticals

    NASA Astrophysics Data System (ADS)

    Dám, A. M.; Gazsó, L. G.; Kaewpila, S.; Maschek, I.

    1996-03-01

    Product specific doses were calculated for pharmaceuticals to be radiation treated. Radio-pasteurization dose were determined for some heat sensitive pharmaceutical basic materials (pancreaton, neopancreatin, neopancreatin USP, duodenum extract). Using the new recommendation (ISO standards, Method 1) dose calculations were performed and radiation sterilization doses were determined for aprotinine and heparine Na.

  8. Underreporting of Fall Injuries of Older Adults: Implications for Wellness Visit Fall Risk Screening.

    PubMed

    Hoffman, Geoffrey J; Ha, Jinkyung; Alexander, Neil B; Langa, Kenneth M; Tinetti, Mary; Min, Lillian C

    2018-04-17

    To compare the accuracy of and factors affecting the accuracy of self-reported fall-related injuries (SFRIs) with those of administratively obtained FRIs (AFRIs). Retrospective observational study SETTING: United States PARTICIPANTS: Fee-for-service Medicare beneficiaries aged 65 and older (N=47,215). We used 24-month self-report recall data from 2000-2012 Health and Retirement Study data to identify SFRIs and linked inpatient, outpatient, and ambulatory Medicare data to identify AFRIs. Sensitivity and specificity were assessed, with AFRIs defined using the University of California at Los Angeles/RAND algorithm as the criterion standard. Logistic regression models were used to identify sociodemographic and health predictors of sensitivity. Overall sensitivity and specificity were 28% and 92%. Sensitivity was greater for the oldest adults (38%), women (34%), those with more functional limitations (47%), and those with a prior fall (38%). In adjusted results, several participant factors (being female, being white, poor functional status, depression, prior falls) were modestly associated with better sensitivity and specificity. Injury severity (requiring hospital care) most substantively improved SFRI sensitivity (73%). An overwhelming 72% of individuals who received Medicare-reimbursed health care for FRIs failed to report a fall injury when asked. Future efforts to address underreporting in primary care of nonwhite and healthier older adults are critical to improve preventive efforts. Redesigned questions-for example, that address stigma of attributing injury to falling-may improve sensitivity. © 2018, Copyright the Authors Journal compilation © 2018, The American Geriatrics Society.

  9. Performance of a histidine-rich protein 2 rapid diagnostic test, Paracheck Pf®, for detection of malaria infections in Ugandan pregnant women.

    PubMed

    Dhorda, Mehul; Piola, Patrice; Nyehangane, Dan; Tumwebaze, Benon; Nalusaji, Aisha; Nabasumba, Carolyn; Turyakira, Eleanor; McGready, Rose; Ashley, Elizabeth; Guerin, Philippe J; Snounou, Georges

    2012-01-01

    Improved laboratory diagnosis is critical to reduce the burden of malaria in pregnancy. Peripheral blood smears appear less sensitive than Plasmodium falciparum histidine-rich protein 2-based rapid diagnostic tests (RDTs) for placental malaria infections in studies conducted at delivery. In this study, 81 women in Uganda in the second or third trimester of pregnancy were followed-up until delivery. At each visit, peripheral blood was tested by blood smear, RDT, and nested species-specific polymerase chain reaction (PCR). Sensitivity and specificity of the tests was calculated with PCR, which detected 22 infections of P. falciparum, as the gold standard. The sensitivity and specificity of blood smears were 36.4% (95% confidence interval [CI] = 18.0-59.2%) and 99.6% (95% CI = 97.7-100%), respectively. The corresponding values for RDT were 31.8% (95% CI = 14.7-54.9%) and 100% (95% CI = 98.3-100%). The RDTs could replace blood smears for diagnosis of malaria in pregnancy by virtue of their relative ease of use. Field-based sensitive tests for malaria in pregnancy are urgently needed.

  10. Diagnostic accuracy of enzyme-linked immunosorbent assay (ELISA) and immunoblot (IB) for the detection of antibodies against Neospora caninum in milk from dairy cows.

    PubMed

    Chatziprodromidou, I P; Apostolou, T

    2018-04-01

    The aim of the study was to estimate the sensitivity and specificity of enzyme-linked immunosorbent assay (ELISA) and immunoblot (IB) for detecting antibodies of Neospora caninum in dairy cows, in the absence of a gold standard. The study complies with STRADAS-paratuberculosis guidelines for reporting the accuracy of the test. We tried to apply Bayesian models that do not require conditional independence of the tests under evaluation, but as convergence problems appeared, we used Bayesian methodology, that does not assume conditional dependence of the tests. Informative prior probability distributions were constructed, based on scientific inputs regarding sensitivity and specificity of the IB test and the prevalence of disease in the studied populations. IB sensitivity and specificity were estimated to be 98.8% and 91.3%, respectively, while the respective estimates for ELISA were 60% and 96.7%. A sensitivity analysis, where modified prior probability distributions concerning IB diagnostic accuracy applied, showed a limited effect in posterior assessments. We concluded that ELISA can be used to screen the bulk milk and secondly, IB can be used whenever needed.

  11. Low cost automated whole smear microscopy screening system for detection of acid fast bacilli.

    PubMed

    Law, Yan Nei; Jian, Hanbin; Lo, Norman W S; Ip, Margaret; Chan, Mia Mei Yuk; Kam, Kai Man; Wu, Xiaohua

    2018-01-01

    In countries with high tuberculosis (TB) burden, there is urgent need for rapid, large-scale screening to detect smear-positive patients. We developed a computer-aided whole smear screening system that focuses in real-time, captures images and provides diagnostic grading, for both bright-field and fluorescence microscopy for detection of acid-fast-bacilli (AFB) from respiratory specimens. To evaluate the performance of dual-mode screening system in AFB diagnostic algorithms on concentrated smears with auramine O (AO) staining, as well as direct smears with AO and Ziehl-Neelsen (ZN) staining, using mycobacterial culture results as gold standard. Adult patient sputum samples requesting for M. tuberculosis cultures were divided into three batches for staining: direct AO-stained, direct ZN-stained and concentrated smears AO-stained. All slides were graded by an experienced microscopist, in parallel with the automated whole smear screening system. Sensitivity and specificity of a TB diagnostic algorithm in using the screening system alone, and in combination with a microscopist, were evaluated. Of 488 direct AO-stained smears, 228 were culture positive. These yielded a sensitivity of 81.6% and specificity of 74.2%. Of 334 direct smears with ZN staining, 142 were culture positive, which gave a sensitivity of 70.4% and specificity of 76.6%. Of 505 concentrated smears with AO staining, 250 were culture positive, giving a sensitivity of 86.4% and specificity of 71.0%. To further improve performance, machine grading was confirmed by manual smear grading when the number of AFBs detected fell within an uncertainty range. These combined results gave significant improvement in specificity (AO-direct:85.4%; ZN-direct:85.4%; AO-concentrated:92.5%) and slight improvement in sensitivity while requiring only limited manual workload. Our system achieved high sensitivity without substantially compromising specificity when compared to culture results. Significant improvement in specificity was obtained when uncertain results were confirmed by manual smear grading. This approach had potential to substantially reduce workload of microscopists in high burden countries.

  12. Assessment of liver fibrosis in chronic hepatitis: comparison of shear wave elastography and transient elastography.

    PubMed

    Paul, Shashi B; Das, Prasenjit; Mahanta, Mousumi; Sreenivas, Vishnubhatla; Kedia, Saurabh; Kalra, Nancy; Kaur, Harpreet; Vijayvargiya, Maneesh; Ghosh, Shouriyo; Gamanagatti, Shivanand R; Shalimar; Gupta, Siddhartha Dutta; Acharya, Subrat K

    2017-12-01

    To evaluate the diagnostic accuracy of shear wave elastography (SWE) and transient elastography (TE) in the evaluation of liver fibrosis in chronic hepatitis B (CHB) and C (CHC) patients taking liver biopsy as gold standard. Ethics committee approved this prospective cross-sectional study. Between October 2012 and December 2014, consecutive CHB/CHC patients fulfilling the inclusion criteria were included-age more than 18 years, informed written consent, willing and suitable for liver biopsy. SWE, TE, and biopsy were performed the same day. Liver stiffness measurement (LSM) cut-offs for various stages of fibrosis were generated for SWE and TE. AUC, sensitivity, specificity, and positive/negative predictive values were estimated individually or in combination. CH patients (n = 240, CHB 172, CHC 68), 176 males, 64 females, mean age 32.6 ± 11.6 years were enrolled. Mean LSM of patients with no histological fibrosis (F0) was 5.0 ± 0.7 and 5.1+1.4 kPa on SWE and TE, respectively. For differentiating F2 and F3-4 fibrosis on SWE, at 7.0 kPa cut-off, the sensitivity was 81.3% and specificity 77.6%. For TE, at 8.3 kPa cut-off, sensitivity was 81.8% and specificity 83.1%. For F3 vs. F4, SWE sensitivity was 83.3% and specificity 90.7%. At 14.8 kPa cut-off, TE showed similar sensitivity (83.3%) but specificity increased to 96.5%. Significant correlation between SWE and TE was observed (r = 0.33, p < 0.001). On combining SWE and TE, a drop in sensitivity with increased specificity for all stages of liver fibrosis occured. SWE is an accurate technique for evaluating liver fibrosis. SWE compares favorably with TE especially for predicting advanced fibrosis/cirrhosis. Combining SWE and TE further improves specificity.

  13. Multicenter comparison of two clinical decision rules for the use of radiography in acute, high-risk knee injuries.

    PubMed

    Seaberg, D C; Yealy, D M; Lukens, T; Auble, T; Mathias, S

    1998-07-01

    Two separate clinical decision rules, one developed in Ottawa and the other in Pittsburgh, for the use of radiography in acute knee injuries have been previously validated and published. In this study, the rules were prospectively validated and compared in a new set of patients. A prospective, blinded, multicenter trial was conducted in the emergency departments of three urban teaching hospitals. A convenience sample of 934 patients with knee pain requiring radiographs was enrolled. A standardized data form was completed for each patient, comprising the 10 clinical variables included in the two rules. Standard knee radiographs were then taken in each patient. The rules were interpreted by the primary investigator on the basis of the data sheet and the final radiologist radiograph reading. In the 745 patients in whom the Pittsburgh rules could be applied there were 91 fractures (12.2%). The use of the Pittsburgh rule missed one fracture, yielding a sensitivity of 99% (95% confidence interval [CI], 94% to 100%); the specificity was 60% (95% CI, 56% to 64%). The Ottawa inclusion criteria were met by 750 patients, with 87 fractures (11.6%). The Ottawa rule missed three fractures, for a sensitivity of 97% (95% CI, 90% to 99%); specificity was 27% (95% CI, 23% to 30%). Prospective validation and comparison found the Pittsburgh rule for knee radiographs to be more specific without loss of sensitivity compared with the Ottawa rule.

  14. SPECT bone scintigraphy for the assessment of condylar growth activity in mandibular asymmetry: is it accurate?

    PubMed

    Chan, B H; Leung, Y Y

    2018-04-01

    The comparison of serial radiographs and clinical photographs is considered the current accepted standard for the diagnosis of active condylar hyperplasia in patients with facial asymmetry. Single photon emission computed tomography (SPECT) has recently been proposed as an alternative method. SPECT can be interpreted using three reported methods absolute difference in uptake, uptake ratio, and relative uptake. SPECT findings were compared to those from serial comparisons of radiographs and clinical photographs taken at the time of SPECT and a year later; the sensitivities and specificities were determined. Two hundred patient scans were evaluated. Thirty-four patients showed active growth on serial growth assessment. On comparison with serial growth assessment, the sensitivity and specificity of the three methods ranged between 32.4% and 67.6%, and 36.1% and 78.3%, respectively. Analysis using receiver operating characteristic (ROC) curves revealed area under the curve (AUC) values of <0.58. The average age (mean±standard deviation) of patients with active growth was 18.6±2.8 years, and average growth in the anteroposterior, vertical, and transverse directions was 0.94±0.91mm, 0.88±0.86mm, and 1.4±0.66 mm, respectively. With such low sensitivity and specificity values, it is not justifiable to use SPECT in place of serial growth assessment for the determination of condylar growth status. Copyright © 2017 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  15. Validation of a short cognitive battery to screen for fitness-to-drive of people with multiple sclerosis.

    PubMed

    Akinwuntan, A E; Backus, D; Grayson, J; Devos, H

    2018-05-26

    Some symptoms of multiple sclerosis (MS) affect driving. In a recent study, performance on five cognitive tests predicted the on-road test performance of individuals with relapsing-remitting MS with 91% accuracy, 70% sensitivity and 97% specificity. However, the accuracy with which the battery will predict the driving performance of a different cohort that includes all types of MS is unknown. Participants (n = 118; 48 ± 9 years of age; 97 females) performed a comprehensive off-road evaluation that lasted about 3 h and a standardized on-road test that lasted approximately 45 min over a 2-day period within the same week. Performance on the five cognitive tests was used to predict participants' performance on the standardized on-road test. Performance on the five tests together predicted outcome of the on-road test with 82% accuracy, 42% sensitivity and 90% specificity. The accuracy of predicting the on-road performance of a new MS cohort using performance on the battery of five cognitive tests remained very high (82%). The battery, which was administrable in <45 min and cost ~$150, was better at identifying those who actually passed the on-road test (90% specificity). The sensitivity (42%) of the battery indicated that it should not be used as the sole determinant of poor driving-related cognitive skills. A fail performance on the battery should only imply that more comprehensive testing is warranted. © 2018 EAN.

  16. Evaluation of IOTA Simple Ultrasound Rules to Distinguish Benign and Malignant Ovarian Tumours.

    PubMed

    Garg, Sugandha; Kaur, Amarjit; Mohi, Jaswinder Kaur; Sibia, Preet Kanwal; Kaur, Navkiran

    2017-08-01

    IOTA stands for International Ovarian Tumour Analysis group. Ovarian cancer is one of the common cancers in women and is diagnosed at later stage in majority. The limiting factor for early diagnosis is lack of standardized terms and procedures in gynaecological sonography. Introduction of IOTA rules has provided some consistency in defining morphological features of ovarian masses through a standardized examination technique. To evaluate the efficacy of IOTA simple ultrasound rules in distinguishing benign and malignant ovarian tumours and establishing their use as a tool in early diagnosis of ovarian malignancy. A hospital based case control prospective study was conducted. Patients with suspected ovarian pathology were evaluated using IOTA ultrasound rules and designated as benign or malignant. Findings were correlated with histopathological findings. Collected data was statistically analysed using chi-square test and kappa statistical method. Out of initial 55 patients, 50 patients were included in the final analysis who underwent surgery. IOTA simple rules were applicable in 45 out of these 50 patients (90%). The sensitivity for the detection of malignancy in cases where IOTA simple rules were applicable was 91.66% and the specificity was 84.84%. Accuracy was 86.66%. Classifying inconclusive cases as malignant, the sensitivity and specificity was 93% and 80% respectively. High level of agreement was found between USG and histopathological diagnosis with Kappa value as 0.323. IOTA simple ultrasound rules were highly sensitive and specific in predicting ovarian malignancy preoperatively yet being reproducible, easy to train and use.

  17. Sensitivity and specificity of automated analysis of single-field non-mydriatic fundus photographs by Bosch DR Algorithm—Comparison with mydriatic fundus photography (ETDRS) for screening in undiagnosed diabetic retinopathy

    PubMed Central

    Bawankar, Pritam; Shanbhag, Nita; K., S. Smitha; Dhawan, Bodhraj; Palsule, Aratee; Kumar, Devesh; Chandel, Shailja

    2017-01-01

    Diabetic retinopathy (DR) is a leading cause of blindness among working-age adults. Early diagnosis through effective screening programs is likely to improve vision outcomes. The ETDRS seven-standard-field 35-mm stereoscopic color retinal imaging (ETDRS) of the dilated eye is elaborate and requires mydriasis, and is unsuitable for screening. We evaluated an image analysis application for the automated diagnosis of DR from non-mydriatic single-field images. Patients suffering from diabetes for at least 5 years were included if they were 18 years or older. Patients already diagnosed with DR were excluded. Physiologic mydriasis was achieved by placing the subjects in a dark room. Images were captured using a Bosch Mobile Eye Care fundus camera. The images were analyzed by the Retinal Imaging Bosch DR Algorithm for the diagnosis of DR. All subjects also subsequently underwent pharmacological mydriasis and ETDRS imaging. Non-mydriatic and mydriatic images were read by ophthalmologists. The ETDRS readings were used as the gold standard for calculating the sensitivity and specificity for the software. 564 consecutive subjects (1128 eyes) were recruited from six centers in India. Each subject was evaluated at a single outpatient visit. Forty-four of 1128 images (3.9%) could not be read by the algorithm, and were categorized as inconclusive. In four subjects, neither eye provided an acceptable image: these four subjects were excluded from the analysis. This left 560 subjects for analysis (1084 eyes). The algorithm correctly diagnosed 531 of 560 cases. The sensitivity, specificity, and positive and negative predictive values were 91%, 97%, 94%, and 95% respectively. The Bosch DR Algorithm shows favorable sensitivity and specificity in diagnosing DR from non-mydriatic images, and can greatly simplify screening for DR. This also has major implications for telemedicine in the use of screening for retinopathy in patients with diabetes mellitus. PMID:29281690

  18. Evaluation of a Smartphone-based Human Activity Recognition System in a Daily Living Environment.

    PubMed

    Lemaire, Edward D; Tundo, Marco D; Baddour, Natalie

    2015-12-11

    An evaluation method that includes continuous activities in a daily-living environment was developed for Wearable Mobility Monitoring Systems (WMMS) that attempt to recognize user activities. Participants performed a pre-determined set of daily living actions within a continuous test circuit that included mobility activities (walking, standing, sitting, lying, ascending/descending stairs), daily living tasks (combing hair, brushing teeth, preparing food, eating, washing dishes), and subtle environment changes (opening doors, using an elevator, walking on inclines, traversing staircase landings, walking outdoors). To evaluate WMMS performance on this circuit, fifteen able-bodied participants completed the tasks while wearing a smartphone at their right front pelvis. The WMMS application used smartphone accelerometer and gyroscope signals to classify activity states. A gold standard comparison data set was created by video-recording each trial and manually logging activity onset times. Gold standard and WMMS data were analyzed offline. Three classification sets were calculated for each circuit: (i) mobility or immobility, ii) sit, stand, lie, or walking, and (iii) sit, stand, lie, walking, climbing stairs, or small standing movement. Sensitivities, specificities, and F-Scores for activity categorization and changes-of-state were calculated. The mobile versus immobile classification set had a sensitivity of 86.30% ± 7.2% and specificity of 98.96% ± 0.6%, while the second prediction set had a sensitivity of 88.35% ± 7.80% and specificity of 98.51% ± 0.62%. For the third classification set, sensitivity was 84.92% ± 6.38% and specificity was 98.17 ± 0.62. F1 scores for the first, second and third classification sets were 86.17 ± 6.3, 80.19 ± 6.36, and 78.42 ± 5.96, respectively. This demonstrates that WMMS performance depends on the evaluation protocol in addition to the algorithms. The demonstrated protocol can be used and tailored for evaluating human activity recognition systems in rehabilitation medicine where mobility monitoring may be beneficial in clinical decision-making.

  19. Automated haematology analysis to diagnose malaria

    PubMed Central

    2010-01-01

    For more than a decade, flow cytometry-based automated haematology analysers have been studied for malaria diagnosis. Although current haematology analysers are not specifically designed to detect malaria-related abnormalities, most studies have found sensitivities that comply with WHO malaria-diagnostic guidelines, i.e. ≥ 95% in samples with > 100 parasites/μl. Establishing a correct and early malaria diagnosis is a prerequisite for an adequate treatment and to minimizing adverse outcomes. Expert light microscopy remains the 'gold standard' for malaria diagnosis in most clinical settings. However, it requires an explicit request from clinicians and has variable accuracy. Malaria diagnosis with flow cytometry-based haematology analysers could become an important adjuvant diagnostic tool in the routine laboratory work-up of febrile patients in or returning from malaria-endemic regions. Haematology analysers so far studied for malaria diagnosis are the Cell-Dyn®, Coulter® GEN·S and LH 750, and the Sysmex XE-2100® analysers. For Cell-Dyn analysers, abnormal depolarization events mainly in the lobularity/granularity and other scatter-plots, and various reticulocyte abnormalities have shown overall sensitivities and specificities of 49% to 97% and 61% to 100%, respectively. For the Coulter analysers, a 'malaria factor' using the monocyte and lymphocyte size standard deviations obtained by impedance detection has shown overall sensitivities and specificities of 82% to 98% and 72% to 94%, respectively. For the XE-2100, abnormal patterns in the DIFF, WBC/BASO, and RET-EXT scatter-plots, and pseudoeosinophilia and other abnormal haematological variables have been described, and multivariate diagnostic models have been designed with overall sensitivities and specificities of 86% to 97% and 81% to 98%, respectively. The accuracy for malaria diagnosis may vary according to species, parasite load, immunity and clinical context where the method is applied. Future developments in new haematology analysers such as considerably simplified, robust and inexpensive devices for malaria detection fitted with an automatically generated alert could improve the detection capacity of these instruments and potentially expand their clinical utility in malaria diagnosis. PMID:21118557

  20. Sensitivity and specificity of automated analysis of single-field non-mydriatic fundus photographs by Bosch DR Algorithm-Comparison with mydriatic fundus photography (ETDRS) for screening in undiagnosed diabetic retinopathy.

    PubMed

    Bawankar, Pritam; Shanbhag, Nita; K, S Smitha; Dhawan, Bodhraj; Palsule, Aratee; Kumar, Devesh; Chandel, Shailja; Sood, Suneet

    2017-01-01

    Diabetic retinopathy (DR) is a leading cause of blindness among working-age adults. Early diagnosis through effective screening programs is likely to improve vision outcomes. The ETDRS seven-standard-field 35-mm stereoscopic color retinal imaging (ETDRS) of the dilated eye is elaborate and requires mydriasis, and is unsuitable for screening. We evaluated an image analysis application for the automated diagnosis of DR from non-mydriatic single-field images. Patients suffering from diabetes for at least 5 years were included if they were 18 years or older. Patients already diagnosed with DR were excluded. Physiologic mydriasis was achieved by placing the subjects in a dark room. Images were captured using a Bosch Mobile Eye Care fundus camera. The images were analyzed by the Retinal Imaging Bosch DR Algorithm for the diagnosis of DR. All subjects also subsequently underwent pharmacological mydriasis and ETDRS imaging. Non-mydriatic and mydriatic images were read by ophthalmologists. The ETDRS readings were used as the gold standard for calculating the sensitivity and specificity for the software. 564 consecutive subjects (1128 eyes) were recruited from six centers in India. Each subject was evaluated at a single outpatient visit. Forty-four of 1128 images (3.9%) could not be read by the algorithm, and were categorized as inconclusive. In four subjects, neither eye provided an acceptable image: these four subjects were excluded from the analysis. This left 560 subjects for analysis (1084 eyes). The algorithm correctly diagnosed 531 of 560 cases. The sensitivity, specificity, and positive and negative predictive values were 91%, 97%, 94%, and 95% respectively. The Bosch DR Algorithm shows favorable sensitivity and specificity in diagnosing DR from non-mydriatic images, and can greatly simplify screening for DR. This also has major implications for telemedicine in the use of screening for retinopathy in patients with diabetes mellitus.

  1. Glaucoma diagnostic performance of GDxVCC and spectralis OCT on eyes with atypical retardation pattern.

    PubMed

    Hoesl, Laura Maria; Tornow, Ralf P; Schrems, Wolfgang A; Horn, Folkert K; Mardin, Christian Y; Kruse, Friedrich E; Juenemann, Anselm G M; Laemmer, Robert

    2013-01-01

    To investigate the impact of typical scan score (TSS) on discriminating glaucomatous and healthy eyes by scanning laser polarimetry and spectral domain optical coherence tomography (SD-OCT) in 32 peripapillary sectors. One hundred two glaucoma patients and 32 healthy controls underwent standard automated perimetry, 24-hour intraocular pressure profile, optic disc photography, GDxVCC, and SD-OCT measurements. For controls, only very typical scans (TSS=100) were accepted. Glaucoma patients were divided into 3 subgroups (very typical: TSS=100; typical: 99≥TSS≥80, atypical: TSS<80). Receiver operating characteristic curves were constructed for mean retinal nerve fiber layer values, sector data, and nerve fiber indicator (NFI). Sensitivity was estimated at ≥90% specificity to compare the discriminating ability of each imaging modality. For discrimination between healthy and glaucomatous eyes with very typical scans, the NFI and inferior sector analyses 26 to 27 demonstrated the highest sensitivity at ≥90% specificity in GDxVCC and SD-OCT, respectively. For the typical and atypical groups, sensitivity at ≥90% specificity decreased for all 32 peripapillary sectors on an average by 10.9% and 17.9% for GDxVCC and by 4.9% and 0.8% for SD-OCT. For GDxVCC, diagnostic performance of peripapillary sectors decreased with lower TSS, especially in temporosuperior and inferotemporal sectors (sensitivity at ≥90% specificity decreased by 55.3% and by 37.8% in the atypical group). Diagnostic accuracy is comparable for SD-OCT and GDxVCC if typical scans (TSS=100) are investigated. Decreasing TSS is associated with a decrease in diagnostic accuracy for discriminating healthy and glaucomatous eyes by scanning laser polarimetry. NFI is less influenced than the global or sector retinal nerve fiber layer thickness. The TSS score should be included in the standard printout. Diagnostic accuracy of SD-OCT is barely influenced by low TSS.

  2. Standard echocardiography versus handheld echocardiography for the detection of subclinical rheumatic heart disease: protocol for a systematic review

    PubMed Central

    Telford, Lisa H; Abdullahi, Leila H; Ochodo, Eleanor A; Engel, Mark E

    2018-01-01

    Introduction Rheumatic heart disease (RHD) is a preventable and treatable chronic condition which persists in many developing countries largely affecting impoverished populations. Handheld echocardiography presents an opportunity to address the need for more cost-effective methods of diagnosing RHD in developing countries, where the disease continues to carry high rates of morbidity and mortality. Preliminary studies have demonstrated moderate sensitivity as well as high specificity and diagnostic odds for detecting RHD in asymptomatic patients. We describe a protocol for a systematic review on the diagnostic performance of handheld echocardiography compared to standard echocardiography using the 2012 World Heart Federation criteria for diagnosing subclinical RHD. Methods and analysis Electronic databases including PubMed, Scopus, Web of Science and EBSCOhost as well as reference lists and citations of relevant articles will be searched from 2012 to date using a predefined strategy incorporating a combination of Medical Subject Heading terms and keywords. The methodological validity and quality of studies deemed eligible for inclusion will be assessed against review specific Quality Assessment of Diagnostic Accuracy Studies 2 criteria and information on metrics of diagnostic accuracy and demographics extracted. Forest plots of sensitivity and specificity as well as scatter plots in receiver operating characteristic (ROC) space will be used to investigate heterogeneity. If possible, a meta-analysis will be conducted to produce summary results of sensitivity and specificity using the Hierarchical Summary ROC method. In addition, a sensitivity analysis will be conducted to investigate the effect of studies with a high risk of bias. Ethics and dissemination Ethics approval is not required for this systematic review of previously published literature. The planned review will provide a summary of the diagnostic accuracy of handheld echocardiography. Results may feed into evidence-based guidelines and should the findings of this review warrant a change in clinical practice, a summary report will be disseminated among leading clinicians and healthcare professionals in the field. PROSPERO registration number CRD42016051261. PMID:29440164

  3. A new portable sulfide monitor with a zinc-oxide semiconductor sensor for daily use and field study.

    PubMed

    Tanda, Naoko; Washio, Jumpei; Ikawa, Kyoko; Suzuki, Kengo; Koseki, Takeyoshi; Iwakura, Masaki

    2007-07-01

    For measuring oral malodor in daily clinical practice and in field study, we developed and evaluated a highly sensitive portable monitor system. We examined sensitivity and specificity of the sensor for volatile sulfur compounds (VSC) and obstructive gases, such as ethanol, acetone, and acetaldehyde. Each mouth air provided by 46 people was measured by this monitor, gas chromatography (GC), and olfactory panel and compared with each other. Based on the result, we used the monitor for mass health examination of a rural town with standardized measuring. The sensor detected hydrogen sulfide, methyl mercaptan, and dimethyl sulfide with 10-1000 times higher sensitivity than the other gases. The monitor's specificity was significantly improved by a VSC-selective filter. There were significant correlations between VSC concentration by the sulfide monitor and by GC, and by organoleptic score. Thirty-six percent of 969 examinees had oral malodor in a rural town. Seventy-eight percent of 969 examinees were motivated to take care of their oral condition by oral malodor measuring with the monitor. The portable sulfide monitor was useful to promote oral health care not only in clinics, but also in field study. The simple and quick operation system and the standardized measuring make it one of parameters of oral condition.

  4. Case definition for clinical and subclinical bacterial kidney disease (BKD) in Atlantic Salmon (Salmo salar L.) in New Brunswick, Canada.

    PubMed

    Boerlage, A S; Stryhn, H; Sanchez, J; Hammell, K L

    2017-03-01

    Bacterial kidney disease (BKD) is considered an important cause of loss in salmon aquaculture in Atlantic Canada. Causative agent of BKD is the Gram-positive bacteria Renibacterium salmoninarum. Infected salmon are often asymptomatic (subclinical infection), and the disease is considered chronic. One of the challenges in quantifying information from farm production and health records is the application of a standardized case definition. Case definitions for farm-level and cage-level clinical and subclinical BKD were developed using retrospective longitudinal data from aquaculture practices in New Brunswick, Canada, combining (i) industry records of weekly production data including mortalities, (ii) field observations for BKD using reports of veterinarians and/or fish health technicians, (iii) diagnostic submissions and test results and (iv) treatments used to control BKD. Case definitions were evaluated using veterinarians' expert judgements as reference standard. Eighty-nine and 66% of sites and fish groups, respectively, were associated with BKD at least once. For BKD present (subclinical or clinical), sensitivity and specificity of the case definition were 75-100% varying between event, fish group, site cycle and level (site pen). For clinical BKD, sensitivities were 29-64% and specificities 91-100%. Industry data can be used to develop sensitive case definitions. © 2016 John Wiley & Sons Ltd.

  5. Validation of the use of self-reported hearing loss and the Hearing Handicap Inventory for elderly among rural Indian elderly population.

    PubMed

    Deepthi, R; Kasthuri, Arvind

    2012-01-01

    Hearing loss is a potentially disabling problem among elderly leading to physical and social dysfunction. Though audiometric assessment of hearing loss is considered as gold standard, it is not feasible in community settings. Several questionnaires measuring hearing handicap have been developed. Knowledge regarding applicability of these questionnaires among rural elderly is limited, hence a study was planned to validate single question and Shortened Hearing Handicap Inventory for Elderly (HHIE-S) in detecting hearing loss against pure tone-audiometry among rural Indian elderly. A single question 'do you feel you have a hearing loss?' and the HHIE-S was administered to 175 elderly in two rural areas. Hearing ability was assessed using pure tone audiometry. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of both screening tools were compared with pure tone averages (PTAs) greater than 25, 40 and 55 dB hearing level (mild, moderate and severe hearing loss, respectively). The single question yielded low sensitivity (30.9%) and high specificity (93.9%) for mild hearing loss. Similarly HHIE-S yielded a sensitivity of 26.2% and specificity of 95.9%. Sensitivity with single question increased to 76.2% and specificity decreased to 83.1% with severe hearing loss. Sensitivity with HHIE-S also increased to 76.2% and specificity decreased to 87.7% with severe hearing loss. These hearing screening questionnaires will be useful in identifying more disabling hearing losses among rural elderly which helps in rehabilitation services planning. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  6. Sensitivity and specificity of diagnostic ultrasound in the diagnosis of phrenic neuropathy.

    PubMed

    Boon, Andrea J; Sekiguchi, Hiroshi; Harper, Caitlin J; Strommen, Jeffrey A; Ghahfarokhi, Leili S; Watson, James C; Sorenson, Eric J

    2014-09-30

    To determine the sensitivity and specificity of B-mode ultrasound in the diagnosis of neuromuscular diaphragmatic dysfunction, including phrenic neuropathy. A prospective study of patients with dyspnea referred to the EMG laboratory over a 2-year time frame for evaluation of neuromuscular respiratory failure who were recruited consecutively and examined with ultrasound for possible diaphragm dysfunction. Sonographic outcome measures were absolute thickness of the diaphragm and degree of increased thickness with maximal inspiration. The comparison standard for diagnosis of diaphragm dysfunction was the final clinical diagnosis of clinicians blinded to the diaphragm ultrasound results, but taking into account other diagnostic workup, including chest radiographs, fluoroscopy, phrenic nerve conduction studies, diaphragm EMG, and/or pulmonary function tests. Of 82 patients recruited over a 2-year period, 66 were enrolled in the study. Sixteen patients were excluded because of inconclusive or insufficient reference testing. One hemidiaphragm could not be adequately visualized; therefore, hemidiaphragm assessment was conducted in a total of 131 hemidiaphragms in 66 patients. Of the 82 abnormal hemidiaphragms, 76 had abnormal sonographic findings (atrophy or decreased contractility). Of the 49 normal hemidiaphragms, none had a false-positive ultrasound. Diaphragmatic ultrasound was 93% sensitive and 100% specific for the diagnosis of neuromuscular diaphragmatic dysfunction. B-mode ultrasound imaging of the diaphragm is a highly sensitive and specific tool for diagnosis of neuromuscular diaphragm dysfunction. This study provides Class II evidence that diaphragmatic ultrasound performed by well-trained individuals accurately identifies patients with neuromuscular diaphragmatic respiratory failure (sensitivity 93%; specificity 100%). © 2014 American Academy of Neurology.

  7. Detecting anxiety in individuals with Parkinson disease: A systematic review.

    PubMed

    Mele, Bria; Holroyd-Leduc, Jayna; Smith, Eric E; Pringsheim, Tamara; Ismail, Zahinoor; Goodarzi, Zahra

    2018-01-02

    To examine diagnostic accuracy of anxiety detection tools compared with a gold standard in outpatient settings among adults with Parkinson disease (PD). A systematic review was conducted. MEDLINE, EMABASE, PsycINFO, and Cochrane Database of Systematic Reviews were searched to April 7, 2017. Prevalence of anxiety and diagnostic accuracy measures including sensitivity, specificity, and likelihood ratios were gathered. Pooled prevalence of anxiety was calculated using Mantel-Haenszel-weighted DerSimonian and Laird models. A total of 6,300 citations were reviewed with 6 full-text articles included for synthesis. Tools included within this study were the Beck Anxiety Inventory, Geriatric Anxiety Inventory (GAI), Hamilton Anxiety Rating Scale, Hospital Anxiety and Depression Scale-Anxiety, Parkinson's Anxiety Scale (PAS), and Mini-Social Phobia Inventory. Anxiety diagnoses made included generalized anxiety disorder, social phobia, and any anxiety type. Pooled prevalence of anxiety was 30.1% (95% confidence interval 26.1%-34.0%). The GAI had the best-reported sensitivity of 0.86 and specificity of 0.88. The observer-rated PAS had a sensitivity of 0.71 and the highest specificity of 0.91. While there are 6 tools validated for anxiety screening in PD populations, most tools are only validated in single studies. The GAI is brief and easy to use, with a good balance of sensitivity and specificity. The PAS was specifically developed for PD, is brief, and has self-/observer-rated scales, but with lower sensitivity. Health care practitioners involved in PD care need to be aware of available validated tools and choose one that fits their practice. Copyright © 2017 American Academy of Neurology.

  8. Analysis of the Sensitivity and Specificity of Noninvasive Imaging Tests for the Diagnosis of Renal Artery Stenosis

    PubMed Central

    Borelli, Flavio Antonio de Oliveira; Pinto, Ibraim M. F.; Amodeo, Celso; Smanio, Paola E. P.; Kambara, Antonio M.; Petisco, Ana Claudia G.; Moreira, Samuel M.; Paiva, Ricardo Calil; Lopes, Hugo Belotti; Sousa, Amanda G. M. R.

    2013-01-01

    Background Aging and atherosclerosis are related to renovascular hypertension in elderly individuals. Regardless of comorbidities, renal artery stenosis is itself an important cause of cardiovascular morbidity and mortality. Objective To define the sensitivity, specificity, positive predictive value, and negative predictive value of noninvasive imaging tests used in the diagnosis of renal artery stenosis. Methods In a group of 61 patients recruited, 122 arteries were analized, thus permitting the definition of sensitivity, specificity, and the relative contribution of each imaging study performed (Doppler, scintigraphy and computed tomographic angiography in comparison to renal arteriography). Results The mean age was 65.43 years (standard deviation: 8.7). Of the variables related to the study population that were compared to arteriography, two correlated with renal artery stenosis, renal dysfunction and triglycerides. The median glomerular filtration rate was 52.8 mL/min/m2. Doppler showed sensitivity of 82.90%, specificity of 70%, a positive predictive value of 85% and negative predictive value of 66.70%. For tomography, sensitivity was 66.70%, specificity 80%, positive predictive value 87.50% and negative predictive value 55.20%. With these findings, we could identify the imaging tests that best detected stenosis. Conclusion Tomography and Doppler showed good quality and efficacy in the diagnosis of renal artery stenosis, with Doppler having the advantage of not requiring the use of contrast medium for the assessment of a disease that is common in diabetics and is associated with renal dysfunction and severe left ventricular dysfunction. PMID:24061685

  9. Performance of the ASAS classification criteria for axial and peripheral spondyloarthritis: a systematic literature review and meta-analysis.

    PubMed

    Sepriano, Alexandre; Rubio, Roxana; Ramiro, Sofia; Landewé, Robert; van der Heijde, Désirée

    2017-05-01

    To summarise the evidence on the performance of the Assessment of SpondyloArthritis international Society (ASAS) classification criteria for axial spondyloarthritis (axSpA) (also imaging and clinical arm separately), peripheral (p)SpA and the entire set, when tested against the rheumatologist's diagnosis ('reference standard'). A systematic literature review was performed to identify eligible studies. Raw data on SpA diagnosis and classification were extracted or, if necessary, obtained from the authors of the selected publications. A meta-analysis was performed to obtain pooled estimates for sensitivity, specificity, positive and negative likelihood ratios, by fitting random effects models. Nine papers fulfilled the inclusion criteria (N=5739 patients). The entire set of the ASAS SpA criteria yielded a high pooled sensitivity (73%) and specificity (88%). Similarly, good results were found for the axSpA criteria (sensitivity: 82%; specificity: 88%). Splitting the axSpA criteria in 'imaging arm only' and 'clinical arm only' resulted in much lower sensitivity (30% and 23% respectively), but very high specificity was retained (97% and 94% respectively). The pSpA criteria were less often tested than the axSpA criteria and showed a similarly high pooled specificity (87%) but lower sensitivity (63%). Accumulated evidence from studies with more than 5500 patients confirms the good performance of the various ASAS SpA criteria as tested against the rheumatologist's diagnosis. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  10. Digital Rectal Examination and Balloon Expulsion Test in the Study of Defecatory Disorders: Are They Suitable as Screening or Excluding Tests?

    PubMed

    Caetano, Ana C; Santa-Cruz, André; Rolanda, Carla

    2016-01-01

    Background . Rome III criteria add physiological criteria to symptom-based criteria of chronic constipation (CC) for the diagnosis of defecatory disorders (DD). However, a gold-standard test is still lacking and physiological examination is expensive and time-consuming. Aim . Evaluate the usefulness of two low-cost tests-digital rectal examination (DRE) and balloon expulsion test (BET)-as screening or excluding tests of DD. Methods . We performed a systematic search in PUBMED and MEDLINE. We selected studies where constipated patients were evaluated by DRE or BET. Heterogeneity was assessed and random effect models were used to calculate the sensitivity, specificity, and negative predictive value (NPV) of the DRE and the BET. Results . Thirteen studies evaluating BET and four studies evaluating DRE (2329 patients) were selected. High heterogeneity ( I 2 > 80%) among studies was demonstrated. The studies evaluating the BET showed a sensitivity and specificity of 67% and 80%, respectively. Regarding the DRE, a sensitivity of 80% and specificity of 84% were calculated. NPV of 72% for the BET and NPV of 64% for the DRE were estimated. The sensitivity and specificity were similar when we restrict the analysis to studies using Rome criteria to define CC. The BET seems to perform better when a cut-off time of 2 minutes is used and when it is compared with a combination of physiological tests. Considering the DRE, strict criteria seem to improve the sensitivity but not the specificity of the test. Conclusion . Neither of the low-cost tests seems suitable for screening or excluding DD.

  11. The CD63 basophil activation test in Hymenoptera venom allergy: a prospective study.

    PubMed

    Sturm, G J; Böhm, E; Trummer, M; Weiglhofer, I; Heinemann, A; Aberer, W

    2004-10-01

    The basophil activation test (BAT), which relies on flow cytometric quantitation of the allergen-induced up-regulation of the granule-associated marker CD63 in peripheral blood basophils, has been suggested to be a useful approach in detecting responsiveness to allergens. The purpose of this study was to establish the usefulness of the BAT with regard to the clinical history and current diagnostic tools in Hymenoptera venom allergy using a prospective study design. Fifty-seven consecutive patients allergic to Hymenoptera venom as defined by a systemic reaction after an insect sting, and 30 age- and sex-matched control subjects with a negative history were included. The degree and nature of sensitization was confirmed by skin testing, specific immunoglobulin E (IgE), serum tryptase levels and BAT. In the nonallergic control group only analysis of specific IgE and BAT were performed. Correlation of BAT, skin test and specific IgE, respectively, with the clinical history in the allergic group was termed as sensitivity and in the control group as specificity. Twenty one of 23 (91.3%) bee venom allergic patients and 29 of 34 (85.3%) patients allergic to wasp and hornet venom tested positive in BAT. The overall sensitivity of BAT, specific IgE and skin tests were 87.7, 91.2 and 93.0%, respectively. The overall specificities were 86.7% for BAT and 66.7% for specific IgE. No correlation between the severity of clinical symptoms and the magnitude of basophil activation was observed. The BAT seems to be an appropriate method to identify patients allergic to bee or wasp venom with a comparable sensitivity to standard diagnostic regimens. The higher specificity of BAT as compared with specific IgE makes this test a useful tool in the diagnosis of Hymenoptera venom allergy.

  12. The after breakfast 50-g, 1-hour glucose challenge test in urban Mexican pregnant women: its sensitivity and specificity evaluated by three diagnostic criteria for gestational diabetes mellitus.

    PubMed

    Espinosa de los Monteros, A; Parra, A; Hidalgo, R; Zambrana, M

    1999-04-01

    To study the sensitivity and specificity of the 50-g, 1-hour gestational glucose challenge test performed 1 to 2 hours after a non-standardized home breakfast in urban Mexican women by using three different gestational diabetes mellitus diagnostic criteria. Four hundred and forty-five consecutive women of 24-28 weeks gestation were studied. The glucose challenge test was performed in the fed state and a week later a fasting 100-g, 3-hours oral glucose tolerance test was carried out in all of them. Duplicate serum glucose concentrations were determined by a glucose-oxidase method. Sensitivity and specificity were calculated using three different diagnostic criteria for gestational diabetes mellitus. The glucose challenge test performed as indicated, with a cutoff of 7.8 mmol/L, had 88-89% sensitivity and 85-87% specificity when using as diagnostic criteria those proposed by the National Diabetes Data Group and by Carpenter & Coustan; by using Sacks et al. criteria, the values were 82% and 88%, respectively. Considering only pregnant women > or = 25 years of age, the sensitivity increased to 92% with the National Diabetes Data Group criteria. Pregnant women < 25 years of age had significantly lower blood glucose values than those with age > or = 25 years during the glucose tolerance test. For the general group the sensitivity of the glucose challenge test performed 1 to 2 hours after breakfast was similar, based on the National Diabetes Data Group and the Carpenter & Coustan's diagnostic criteria for gestational diabetes mellitus. However, when pregnant women > or = 25 years of age were considered, the use of the former criteria yielded a slightly better sensitivity.

  13. Detection of Bone Marrow Edema in Nondisplaced Hip Fractures: Utility of a Virtual Noncalcium Dual-Energy CT Application.

    PubMed

    Kellock, Trenton T; Nicolaou, Savvas; Kim, Sandra S Y; Al-Busaidi, Sultan; Louis, Luck J; O'Connell, Tim W; Ouellette, Hugue A; McLaughlin, Patrick D

    2017-09-01

    Purpose To quantify the sensitivity and specificity of dual-energy computed tomographic (CT) virtual noncalcium images in the detection of nondisplaced hip fractures and to assess whether obtaining these images as a complement to bone reconstructions alters sensitivity, specificity, or diagnostic confidence. Materials and Methods The clinical research ethics board approved chart review, and the requirement to obtain informed consent was waived. The authors retrospectively identified 118 patients who presented to a level 1 trauma center emergency department and who underwent dual-energy CT for suspicion of a nondisplaced traumatic hip fracture. Clinical follow-up was the standard of reference. Three radiologists interpreted virtual noncalcium images for traumatic bone marrow edema. Bone reconstructions for the same cases were interpreted alone and then with virtual noncalcium images. Diagnostic confidence was rated on a scale of 1 to 10. McNemar, Fleiss κ, and Wilcoxon signed-rank tests were used for statistical analysis. Results Twenty-two patients had nondisplaced hip fractures and 96 did not have hip fractures. Sensitivity with virtual noncalcium images was 77% and 91% (17 and 20 of 22 patients), and specificity was 92%-99% (89-95 of 96 patients). Sensitivity increased by 4%-5% over that with bone reconstruction images alone for two of the three readers when both bone reconstruction and virtual noncalcium images were used. Specificity remained unchanged (99% and 100%). Diagnostic confidence in the exclusion of fracture was improved with combined bone reconstruction and virtual noncalcium images (median score: 10, 9, and 10 for readers 1, 2, and 3, respectively) compared with bone reconstruction images alone (median score: 9, 8, and 9). Conclusion When used as a supplement to standard bone reconstructions, dual-energy CT virtual noncalcium images increased sensitivity for the detection of nondisplaced traumatic hip fractures and improved diagnostic confidence in the exclusion of these fractures. © RSNA, 2017 Online supplemental material is available for this article. An earlier incorrect version of this article appeared online. This article was corrected on March 17, 2017.

  14. Assessment of methicillin resistant Staphylococcus Aureus detection methods: analytical comparative study.

    PubMed

    Ibrahim, Omer Mohammed Ali; Bilal, Naser Eldin; Osman, Omran Fadl; Magzoub, Magzoub Abbas

    2017-01-01

    The heterogeneous expression of methicillin resistance in Staphylococcus aureus (MRSA) affects the efficiency of tests available to detect it. The objective of this study was to assess four phenotypic tests used to detect MRSA. This is an analytical comparative study conducted among sudanese patients during period from May 2012 to July 2014, Staphylococcus aureus strains were isolated and identified by conventional methods, and then confirmed by PCR detection of coagulase gene. PCR detection of mecA gene was used as a gold standard to assess oxacillin resistance screen agar base (ORSAB), oxacillin disc, cefoxitin disc (at different temperatures and incubation periods) and MRSA-latex agglutination test. S.aureus ATCC 25923 was used as control. Sensitivity and specificity were calculated. MRSA- latex agglutination was the most accurate test; it showed 100% of both sensitivity and specificity, followed by cefoxitin disc with sensitivity of 98.48% and specificity of 100%. However, both of oxacillin disc and oxacillin resistance screen agar base showed less accurate results, and were affected by incubation periods. Oxacillin disc after 24 h incubation both at 30°C and 35°C showed sensitivity and specificity values of 87.88% and 96.23%, respectively. However, after 48h incubation the test at 30°C showed sensitivity and specificity values of 89.39%, and 94.34%, respectively. At 35°C (48h) it showed values of 89.39%, 92.45% respectively. Specificity of ORSAB was more than oxacillin disc at 35°C after 24h incubation 98.11% and 96.23%, respectively. MRSA- latex agglutination and cefoxitin disc diffusion tests are recommended for routine detection of MRSA.

  15. The use of hippocampal volumetric measurements to improve diagnostic accuracy in pediatric patients with mesial temporal sclerosis.

    PubMed

    Guzmán Pérez-Carrillo, Gloria J; Owen, Christopher; Schwetye, Katherine E; McFarlane, Spencer; Vellimana, Ananth K; Mar, Soe; Miller-Thomas, Michelle M; Shimony, Joshua S; Smyth, Matthew D; Benzinger, Tammie L S

    2017-06-01

    OBJECTIVE Many patients with medically intractable epilepsy have mesial temporal sclerosis (MTS), which significantly affects their quality of life. The surgical excision of MTS lesions can result in marked improvement or even complete resolution of the epileptic episodes. Reliable radiological diagnosis of MTS is a clinical challenge. The purpose of this study was to evaluate the utility of volumetric mapping of the hippocampi for the identification of MTS in a case-controlled series of pediatric patients who underwent resection for medically refractory epilepsy, using pathology as a gold standard. METHODS A cohort of 57 pediatric patients who underwent resection for medically intractable epilepsy between 2005 and 2015 was evaluated. On pathological investigation, this group included 24 patients with MTS and 33 patients with non-MTS findings. Retrospective quantitative volumetric measurements of the hippocampi were acquired for 37 of these 57 patients. Two neuroradiologists with more than 10 years of experience who were blinded to the patients' MTS status performed the retrospective review of MR images. To produce the volumetric data, MR scans were parcellated and segmented using the FreeSurfer software suite. Hippocampal regions of interest were compared against an age-weighted local regression curve generated with data from the pediatric normal cohort. Standard deviations and percentiles of specific subjects were calculated. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were determined for the original clinical read and the expert readers. Receiver operating characteristic curves were generated for the methods of classification to compare results from the readers with the authors' results, and an optimal threshold was determined. From that threshold the sensitivity, specificity, PPV, and NPV were calculated for the volumetric analysis. RESULTS With the use of quantitative volumetry, a sensitivity of 72%, a specificity of 95%, a PPV of 93%, an NPV of 78%, and an area under the curve of 0.84 were obtained using a percentage difference of normalized hippocampal volume. The resulting specificity (95%) and PPV (93%) are superior to the original clinical read and to Reader A and Reader B's findings (range for specificity 74%-86% and for PPV 64%-71%). The sensitivity (72%) and NPV (78%) are comparable to Reader A's findings (73% and 81%, respectively) and are better than those of the original clinical read and of Reader B (sensitivity 45% and 63% and NPV 71% and 70%, respectively). CONCLUSIONS Volumetric measurement of the hippocampi outperforms expert readers in specificity and PPV, and it demonstrates comparable to superior sensitivity and NPV. Volumetric measurements can complement anatomical imaging for the identification of MTS, much like a computer-aided detection tool would. The implementation of this approach in the daily clinical workflow could significantly improve diagnostic accuracy.

  16. Multicenter evaluation of stress-first myocardial perfusion image triage by nuclear technologists and automated quantification.

    PubMed

    Chaudhry, Waseem; Hussain, Nasir; Ahlberg, Alan W; Croft, Lori B; Fernandez, Antonio B; Parker, Mathew W; Swales, Heather H; Slomka, Piotr J; Henzlova, Milena J; Duvall, W Lane

    2017-06-01

    A stress-first myocardial perfusion imaging (MPI) protocol saves time, is cost effective, and decreases radiation exposure. A limitation of this protocol is the requirement for physician review of the stress images to determine the need for rest images. This hurdle could be eliminated if an experienced technologist and/or automated computer quantification could make this determination. Images from consecutive patients who were undergoing a stress-first MPI with attenuation correction at two tertiary care medical centers were prospectively reviewed independently by a technologist and cardiologist blinded to clinical and stress test data. Their decision on the need for rest imaging along with automated computer quantification of perfusion results was compared with the clinical reference standard of an assessment of perfusion images by a board-certified nuclear cardiologist that included clinical and stress test data. A total of 250 patients (mean age 61 years and 55% female) who underwent a stress-first MPI were studied. According to the clinical reference standard, 42 (16.8%) and 208 (83.2%) stress-first images were interpreted as "needing" and "not needing" rest images, respectively. The technologists correctly classified 229 (91.6%) stress-first images as either "needing" (n = 28) or "not needing" (n = 201) rest images. Their sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were 66.7%, 96.6%, 80.0%, and 93.5%, respectively. An automated stress TPD score ≥1.2 was associated with optimal sensitivity and specificity and correctly classified 179 (71.6%) stress-first images as either "needing" (n = 31) or "not needing" (n = 148) rest images. Its sensitivity, specificity, PPV, and NPV were 73.8%, 71.2%, 34.1%, and 93.1%, respectively. In a model whereby the computer or technologist could correct for the other's incorrect classification, 242 (96.8%) stress-first images were correctly classified. The composite sensitivity, specificity, PPV, and NPV were 83.3%, 99.5%, 97.2%, and 96.7%, respectively. Technologists and automated quantification software had a high degree of agreement with the clinical reference standard for determining the need for rest images in a stress-first imaging protocol. Utilizing an experienced technologist and automated systems to screen stress-first images could expand the use of stress-first MPI to sites where the cardiologist is not immediately available for interpretation.

  17. Identifying depression with the PHQ-2: A diagnostic meta-analysis.

    PubMed

    Manea, Laura; Gilbody, Simon; Hewitt, Catherine; North, Alice; Plummer, Faye; Richardson, Rachel; Thombs, Brett D; Williams, Bethany; McMillan, Dean

    2016-10-01

    There is interest in the use of very brief instruments to identify depression because of the advantages they offer in busy clinical settings. The PHQ-2, consisting of two questions relating to core symptoms of depression (low mood and loss of interest or pleasure), is one such instrument. A systematic review was conducted to identify studies that had assessed the diagnostic performance of the PHQ-2 to detect major depression. Embase, MEDLINE, PsychINFO and grey literature databases were searched. Reference lists of included studies and previous relevant reviews were also examined. Studies were included that used the standard scoring system of the PHQ-2, assessed its performance against a gold-standard diagnostic interview and reported data on its performance at the recommended (≥3) or an alternative cut-off point (≥2). After assessing heterogeneity, where appropriate, data from studies were combined using bivariate diagnostic meta-analysis to derive sensitivity, specificity, likelihood ratios and diagnostic odds ratios. 21 studies met inclusion criteria totalling N=11,175 people out of which 1529 had major depressive disorder according to a gold standard. 19 of the 21 included studies reported data for a cut-off point of ≥3. Pooled sensitivity was 0.76 (95% CI =0.68-0.82), pooled specificity was 0.87 (95% CI =0.82-0.90). However there was substantial heterogeneity at this cut-off (I(2)=81.8%). 17 studies reported data on the performance of the measure at cut-off point ≥2. Heterogeneity was I(2)=43.2% pooled sensitivity at this cut-off point was 0.91 (95% CI =0.85-0.94), and pooled specificity was 0.70 (95% CI =0.64-0.76). The generally lower sensitivity of the PHQ-2 at cut-off ≥3 than the original validation study (0.83) suggests that ≥2 may be preferable if clinicians want to ensure that few cases of depression are missed. However, in situations in which the prevalence of depression is low, this may result in an unacceptably high false-positive rate because of the associated modest specificity. These results, however, need to be interpreted with caution given the possibility of selectively reported cut-offs. Copyright © 2016. Published by Elsevier B.V.

  18. Diagnostic Performance of Ultrafast Brain MRI for Evaluation of Abusive Head Trauma.

    PubMed

    Kralik, S F; Yasrebi, M; Supakul, N; Lin, C; Netter, L G; Hicks, R A; Hibbard, R A; Ackerman, L L; Harris, M L; Ho, C Y

    2017-04-01

    MR imaging with sedation is commonly used to detect intracranial traumatic pathology in the pediatric population. Our purpose was to compare nonsedated ultrafast MR imaging, noncontrast head CT, and standard MR imaging for the detection of intracranial trauma in patients with potential abusive head trauma. A prospective study was performed in 24 pediatric patients who were evaluated for potential abusive head trauma. All patients received noncontrast head CT, ultrafast brain MR imaging without sedation, and standard MR imaging with general anesthesia or an immobilizer, sequentially. Two pediatric neuroradiologists independently reviewed each technique blinded to other modalities for intracranial trauma. We performed interreader agreement and consensus interpretation for standard MR imaging as the criterion standard. Diagnostic accuracy was calculated for ultrafast MR imaging, noncontrast head CT, and combined ultrafast MR imaging and noncontrast head CT. Interreader agreement was moderate for ultrafast MR imaging (κ = 0.42), substantial for noncontrast head CT (κ = 0.63), and nearly perfect for standard MR imaging (κ = 0.86). Forty-two percent of patients had discrepancies between ultrafast MR imaging and standard MR imaging, which included detection of subarachnoid hemorrhage and subdural hemorrhage. Sensitivity, specificity, and positive and negative predictive values were obtained for any traumatic pathology for each examination: ultrafast MR imaging (50%, 100%, 100%, 31%), noncontrast head CT (25%, 100%, 100%, 21%), and a combination of ultrafast MR imaging and noncontrast head CT (60%, 100%, 100%, 33%). Ultrafast MR imaging was more sensitive than noncontrast head CT for the detection of intraparenchymal hemorrhage ( P = .03), and the combination of ultrafast MR imaging and noncontrast head CT was more sensitive than noncontrast head CT alone for intracranial trauma ( P = .02). In abusive head trauma, ultrafast MR imaging, even combined with noncontrast head CT, demonstrated low sensitivity compared with standard MR imaging for intracranial traumatic pathology, which may limit its utility in this patient population. © 2017 by American Journal of Neuroradiology.

  19. Field evaluation of a malaria rapid diagnostic test (ICT Pf).

    PubMed

    Moonasar, Devanand; Goga, Ameena E; Kruger, Philip S; La Cock, Christine; Maharaj, Rajendra; Frean, John; Chandramohan, Daniel

    2009-11-01

    Malaria rapid diagnostic tests (MRDTs) are quick and easy to perform and useful for diagnosing malaria in primary health care settings. In South Africa most malaria infections are due to Plasmodium falciparurrm, and HRPII-based MRDTs have been used since 2001. Previous studies in Africa showed variability in sensitivity and specificity of HRPII-based MRDTs; hence, we conducted a field evaluation in Limpopo province to determine the accuracy of the MRDT currently used in public sector clinics and hospitals. A cross-sectional observational study was conducted to determine the sensitivity and specificity of an ICT Pf MRDT. We tested 405 patients with fever with ICT Pf MRDT and compared the results with blood film microscopy (the gold standard). RESULTS. The overall sensitivity of the ICT Pf MRDT was 99.48% (95% confidence interval (CI) 96.17-100%), while specificity was 96.26% (95% CI 94.7-100%). The positive predictive value of the test was 98.48 (99% CI 98.41-100%), and the negative predictive value was 99.52% (95% CI 96.47-100%). The ICT Pf MRDT is an appropriate test to use in the field in South Africa where laboratory facilities are not available. It has a high degree of sensitivity and acceptable level of specificity in accordance with the World Health Organization criteria. However, sensitivity of MRDT at low levels of parasitaemia (<100 parasites/microl of blood) in field conditions must still be established.

  20. An in vitro human skin test for assessing sensitization potential.

    PubMed

    Ahmed, S S; Wang, X N; Fielding, M; Kerry, A; Dickinson, I; Munuswamy, R; Kimber, I; Dickinson, A M

    2016-05-01

    Sensitization to chemicals resulting in an allergy is an important health issue. The current gold-standard method for identification and characterization of skin-sensitizing chemicals was the mouse local lymph node assay (LLNA). However, for a number of reasons there has been an increasing imperative to develop alternative approaches to hazard identification that do not require the use of animals. Here we describe a human in-vitro skin explant test for identification of sensitization hazards and the assessment of relative skin sensitizing potency. This method measures histological damage in human skin as a readout of the immune response induced by the test material. Using this approach we have measured responses to 44 chemicals including skin sensitizers, pre/pro-haptens, respiratory sensitizers, non-sensitizing chemicals (including skin-irritants) and previously misclassified compounds. Based on comparisons with the LLNA, the skin explant test gave 95% specificity, 95% sensitivity, 95% concordance with a correlation coefficient of 0.9. The same specificity and sensitivity were achieved for comparison of results with published human sensitization data with a correlation coefficient of 0.91. The test also successfully identified nickel sulphate as a human skin sensitizer, which was misclassified as negative in the LLNA. In addition, sensitizers and non-sensitizers identified as positive or negative by the skin explant test have induced high/low T cell proliferation and IFNγ production, respectively. Collectively, the data suggests the human in-vitro skin explant test could provide the basis for a novel approach for characterization of the sensitizing activity as a first step in the risk assessment process. Copyright © 2015 John Wiley & Sons, Ltd.

  1. [Analytical performances of real-time PCR by Abbott RealTime CMV with m2000 for the detection of cytomegalovirus in urine].

    PubMed

    De Monte, Anne; Cannavo, Isabelle; Caramella, Anne; Ollier, Laurence; Giordanengo, Valérie

    2016-01-01

    Congenital cytomegalovirus (CMV) infection is the leading cause of sensoneurinal disability due to infectious congenital disease. The diagnosis of congenital CMV infection is based on the search of CMV in the urine within the first two weeks of life. Viral culture of urine is the gold standard. However, the PCR is highly sensitive and faster. It is becoming an alternative choice. The objective of this study is the validation of real-time PCR by Abbott RealTime CMV with m2000 for the detection of cytomegalovirus in urine. Repeatability, reproducibility, detection limit and inter-sample contamination were evaluated. Urine samples from patients (n=141) were collected and analyzed simultaneously in culture and PCR in order to assess the correlation of these two methods. The sensitivity and specificity of PCR were also calculated. The Abbott RealTime CMV PCR in urine is an automated and sensitive method (detection limit 200 UI/mL). Fidelity is very good (standard deviation of repeatability: 0.08 to 0.15 LogUI/mL and reproducibility 0.18 LogUI/mL). We can note a good correlation between culture and Abbott RealTime CMV PCR (kappa 96%). When considering rapid culture as reference, real-time PCR was highly sensitive (100%) and specific (98.2%). The real-time PCR by Abbott RealTime CMV with m2000 is optimal for CMV detection in urine.

  2. Systematic Review of the Performance of Noninvasive Tests in Diagnosing Bladder Outlet Obstruction in Men with Lower Urinary Tract Symptoms.

    PubMed

    Malde, Sachin; Nambiar, Arjun K; Umbach, Roland; Lam, Thomas B; Bach, Thorsten; Bachmann, Alexander; Drake, Marcus J; Gacci, Mauro; Gratzke, Christian; Madersbacher, Stephan; Mamoulakis, Charalampos; Tikkinen, Kari A O; Gravas, Stavros

    2017-03-01

    Several noninvasive tests have been developed for diagnosing bladder outlet obstruction (BOO) in men to avoid the burden and morbidity associated with invasive urodynamics. The diagnostic accuracy of these tests, however, remains uncertain. To systematically review available evidence regarding the diagnostic accuracy of noninvasive tests in diagnosing BOO in men with lower urinary tract symptoms (LUTS) using a pressure-flow study as the reference standard. The EMBASE, MEDLINE, Cochrane Database of Systematic Reviews, Cochrane Central, Google Scholar, and WHO International Clinical Trials Registry Platform Search Portal databases were searched up to May 18, 2016. All studies reporting diagnostic accuracy for noninvasive tests for BOO or detrusor underactivity in men with LUTS compared to pressure-flow studies were included. Two reviewers independently screened all articles, searched the reference lists of retrieved articles, and performed the data extraction. The quality of evidence and risk of bias were assessed using the QUADAS-2 tool. The search yielded 2774 potentially relevant reports. After screening titles and abstracts, 53 reports were retrieved for full-text screening, of which 42 (recruiting a total of 4444 patients) were eligible. Overall, the results were predominantly based on findings from nonrandomised experimental studies and, within the limits of such study designs, the quality of evidence was typically moderate across the literature. Differences in noninvasive test threshold values and variations in the urodynamic definition of BOO between studies limited the comparability of the data. Detrusor wall thickness (median sensitivity 82%, specificity 92%), near-infrared spectroscopy (median sensitivity 85%, specificity 87%), and the penile cuff test (median sensitivity 88%, specificity 75%) were all found to have high sensitivity and specificity in diagnosing BOO. Uroflowmetry with a maximum flow rate of <10ml/s was reported to have lower median sensitivity and specificity of 68% and 70%, respectively. Intravesical prostatic protrusion of >10mm was reported to have similar diagnostic accuracy, with median sensitivity of 68% and specificity of 75%. According to the literature, a number of noninvasive tests have high sensitivity and specificity in diagnosing BOO in men. However, although the majority of studies have a low overall risk of bias, the available evidence is limited by heterogeneity. While several tests have shown promising results regarding noninvasive assessment of BOO, invasive urodynamics remain the gold standard. Urodynamics is an accurate but potentially uncomfortable test for patients in diagnosing bladder problems such as obstruction. We performed a thorough and comprehensive review of the literature to determine if there were less uncomfortable but equally effective alternatives to urodynamics for diagnosing bladder problems. We found that some simple tests appear to be promising, although they are not as accurate. Further research is needed before these tests are routinely used in place of urodynamics. Copyright © 2016 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  3. The concurrent validity of the Problem Oriented Screening Instrument for Teenagers (POSIT) substance use/abuse subscale in adolescent patients in an urban federally qualified health center.

    PubMed

    Kelly, Sharon M; O'Grady, Kevin E; Gryczynski, Jan; Mitchell, Shannon Gwin; Kirk, Arethusa; Schwartz, Robert P

    2017-01-01

    The Problem Oriented Screening Instrument for Teenagers (POSIT) substance use/abuse subscale has been validated with high school students, adolescents with criminal justice involvement, and adolescent substance use treatment samples using the Diagnostic and Statistical Manual of Mental Disorders (DSM)-III-R and DSM-IV. This study examines the concurrent validity of the POSIT's standard 17-item substance use/abuse subscale and a revised, shorter 11-item version using DSM-5 substance use disorder diagnoses. Adolescents (N = 525; 93% African American, 55% female) 12-17 years of age awaiting primary care appointments at a Federally Qualified Health Center in Baltimore, Maryland completed the 17-item POSIT substance use/abuse subscale and items from a modified World Mental Health Composite International Diagnostic Interview corresponding to DSM-5 alcohol use disorder (AUD) and cannabis use disorder (CUD). Receiver operating characteristic curves, sensitivities, and specificities were examined with DSM-5 AUD, CUD, and a diagnosis of either or both disorders for the standard and revised subscales using risk cutoffs of either 1 or 2 POSIT "yes" responses. For the 17-item subscale, sensitivities were generally high using either cutoff (range: 0.79-1.00), although a cutoff of 1 was superior (sensitivities were 1.00 for AUD, CUD, and for either disorder). Specificities were also high using either cutoff (range: 0.81-0.95) but were higher using a cutoff of 2. For the 11-item subscale, a cutoff of 1 yielded higher sensitivities than a cutoff of 2 (ranges for 1 and 2: 0.96-1.00 and 0.79-0.86, respectively). Specificities for this subscale were higher using a cutoff of 2 (ranges for 1 and 2: 0.82-0.89 and 0.89-0.96, respectively). Findings suggest that the POSIT's substance use/abuse subscale is a potentially useful tool for screening adolescents in primary care for AUD or CUD using a cutoff of 1 or 2. The briefer, revised subscale may be preferable to the standard subscale in busy pediatric practices.

  4. Can optical diagnosis of small colon polyps be accurate? Comparing standard scope without narrow banding to high definition scope with narrow banding.

    PubMed

    Ashktorab, Hassan; Etaati, Firoozeh; Rezaeean, Farahnaz; Nouraie, Mehdi; Paydar, Mansour; Namin, Hassan Hassanzadeh; Sanderson, Andrew; Begum, Rehana; Alkhalloufi, Kawtar; Brim, Hassan; Laiyemo, Adeyinka O

    2016-07-28

    To study the accuracy of using high definition (HD) scope with narrow band imaging (NBI) vs standard white light colonoscope without NBI (ST), to predict the histology of the colon polyps, particularly those < 1 cm. A total of 147 African Americans patients who were referred to Howard University Hospital for screening or, diagnostic or follow up colonoscopy, during a 12-mo period in 2012 were prospectively recruited. Some patients had multiple polyps and total number of polyps was 179. Their colonoscopies were performed by 3 experienced endoscopists who determined the size and stated whether the polyps being removed were hyperplastic or adenomatous polyps using standard colonoscopes or high definition colonoscopes with NBI. The histopathologic diagnosis was reported by pathologists as part of routine care. Of participants in the study, 55 (37%) were male and median (interquartile range) of age was 56 (19-80). Demographic, clinical characteristics, past medical history of patients, and the data obtained by two instruments were not significantly different and two methods detected similar number of polyps. In ST scope 89% of polyps were < 1 cm vs 87% in HD scope (P = 0.7). The ST scope had a positive predictive value (PPV) and positive likelihood ratio (PLR) of 86% and 4.0 for adenoma compared to 74% and 2.6 for HD scope. There was a trend of higher sensitivity for HD scope (68%) compare to ST scope (53%) with almost the same specificity. The ST scope had a PPV and PLR of 38% and 1.8 for hyperplastic polyp (HPP) compared to 42% and 2.2 for HD scope. The sensitivity and specificity of two instruments for HPP diagnosis were similar. Our results indicated that HD scope was more sensitive in diagnosis of adenoma than ST scope. Clinical diagnosis of HPP with either scope is less accurate compared to adenoma. Colonoscopy diagnosis is not yet fully matched with pathologic diagnosis of colon polyp. However with the advancement of both imaging and training, it may be possible to increase the sensitivity and specificity of the scopes and hence save money for eliminating time and the cost of Immunohistochemistry/pathology.

  5. The impact of slice-reduced computed tomography on histogram-based densitometry assessment of lung fibrosis in patients with systemic sclerosis.

    PubMed

    Nguyen-Kim, Thi Dan Linh; Maurer, Britta; Suliman, Yossra A; Morsbach, Fabian; Distler, Oliver; Frauenfelder, Thomas

    2018-04-01

    To evaluate usability of slice-reduced sequential computed tomography (CT) compared to standard high-resolution CT (HRCT) in patients with systemic sclerosis (SSc) for qualitative and quantitative assessment of interstitial lung disease (ILD) with respect to (I) detection of lung parenchymal abnormalities, (II) qualitative and semiquantitative visual assessment, (III) quantification of ILD by histograms and (IV) accuracy for the 20%-cut off discrimination. From standard chest HRCT of 60 SSc patients sequential 9-slice-computed tomography (reduced HRCT) was retrospectively reconstructed. ILD was assessed by visual scoring and quantitative histogram parameters. Results from standard and reduced HRCT were compared using non-parametric tests and analysed by univariate linear regression analyses. With respect to the detection of parenchymal abnormalities, only the detection of intrapulmonary bronchiectasis was significantly lower in reduced HRCT compared to standard HRCT (P=0.039). No differences were found comparing visual scores for fibrosis severity and extension from standard and reduced HRCT (P=0.051-0.073). All scores correlated significantly (P<0.001) to histogram parameters derived from both, standard and reduced HRCT. Significant higher values of kurtosis and skewness for reduced HRCT were found (both P<0.001). In contrast to standard HRCT histogram parameters from reduced HRCT showed significant discrimination at cut-off 20% fibrosis (sensitivity 88% kurtosis and skewness; specificity 81% kurtosis and 86% skewness; cut-off kurtosis ≤26, cut-off skewness ≤4; both P<0.001). Reduced HRCT is a robust method to assess lung fibrosis in SSc with minimal radiation dose with no difference in scoring assessment of lung fibrosis severity and extension in comparison to standard HRCT. In contrast to standard HRCT histogram parameters derived from the approach of reduced HRCT could discriminate at a threshold of 20% lung fibrosis with high sensitivity and specificity. Hence it might be used to detect early disease progression of lung fibrosis in context of monitoring and treatment of SSc patients.

  6. Evaluation of acute knee pain in primary care.

    PubMed

    Jackson, Jeffrey L; O'Malley, Patrick G; Kroenke, Kurt

    2003-10-07

    The evaluation of acute knee pain often includes radiography of the knee. To synthesize the literature to determine the role of radiologic procedures in evaluating common causes of acute knee pain: fractures, meniscal or ligamentous injuries, osteoarthritis, and pseudogout. MEDLINE search from 1966 to October 2002. We included all published, peer-reviewed studies of decision rules for fractures. We included studies that used arthroscopy as the gold standard for measuring the accuracy of the physical examination and magnetic resonance imaging (MRI) for meniscal and ligamentous knee damage. We included all studies on the use of radiographs in pseudogout. We extracted all data in duplicate and abstracted physical examination and MRI results into 2 x 2 tables. Among the 5 decision rules for deciding when to use plain films in knee fractures, the Ottawa knee rules (injury due to trauma and age >55 years, tenderness at the head of the fibula or the patella, inability to bear weight for 4 steps, or inability to flex the knee to 90 degrees) have the strongest supporting evidence. When the history suggests a potential meniscal or ligamentous injury, the physical examination is moderately sensitive (meniscus, 87%; anterior cruciate ligament, 74%; and posterior cruciate ligament, 81%) and specific (meniscus, 92%; anterior cruciate ligament, 95%; and posterior cruciate ligament, 95%). The Lachman test is more sensitive and specific for ligamentous tears than is the drawer sign. For meniscal tears, joint line tenderness is sensitive (75%) but not specific (27%), while the McMurray test is specific (97%) but not sensitive (52%). Compared with the physical examination, MRI is more sensitive for ligamentous and meniscal damage but less specific. When the differential diagnosis for acute knee pain includes an exacerbation of osteoarthritis, clinical features (age >50 years, morning stiffness <30 minutes, crepitus, or bony enlargement) are 89% sensitive and 88% specific for underlying chronic arthritis. Adding plain films improves sensitivity slightly but not specificity. Plain films for pseudogout are not sensitive or specific, according to limited-quality studies. We recommend the Ottawa knee rules to decide when to obtain plain films for suspected knee fracture. A careful physical examination should be sufficient to decide whether to refer patients with potential meniscal and ligament injuries, and we prefer clinical criteria rather than plain films for evaluating osteoarthritis. We do not recommend using plain films to diagnose pseudogout.

  7. Alternative Confidence Interval Methods Used in the Diagnostic Accuracy Studies

    PubMed Central

    Gülhan, Orekıcı Temel

    2016-01-01

    Background/Aim. It is necessary to decide whether the newly improved methods are better than the standard or reference test or not. To decide whether the new diagnostics test is better than the gold standard test/imperfect standard test, the differences of estimated sensitivity/specificity are calculated with the help of information obtained from samples. However, to generalize this value to the population, it should be given with the confidence intervals. The aim of this study is to evaluate the confidence interval methods developed for the differences between the two dependent sensitivity/specificity values on a clinical application. Materials and Methods. In this study, confidence interval methods like Asymptotic Intervals, Conditional Intervals, Unconditional Interval, Score Intervals, and Nonparametric Methods Based on Relative Effects Intervals are used. Besides, as clinical application, data used in diagnostics study by Dickel et al. (2010) has been taken as a sample. Results. The results belonging to the alternative confidence interval methods for Nickel Sulfate, Potassium Dichromate, and Lanolin Alcohol are given as a table. Conclusion. While preferring the confidence interval methods, the researchers have to consider whether the case to be compared is single ratio or dependent binary ratio differences, the correlation coefficient between the rates in two dependent ratios and the sample sizes. PMID:27478491

  8. Alternative Confidence Interval Methods Used in the Diagnostic Accuracy Studies.

    PubMed

    Erdoğan, Semra; Gülhan, Orekıcı Temel

    2016-01-01

    Background/Aim. It is necessary to decide whether the newly improved methods are better than the standard or reference test or not. To decide whether the new diagnostics test is better than the gold standard test/imperfect standard test, the differences of estimated sensitivity/specificity are calculated with the help of information obtained from samples. However, to generalize this value to the population, it should be given with the confidence intervals. The aim of this study is to evaluate the confidence interval methods developed for the differences between the two dependent sensitivity/specificity values on a clinical application. Materials and Methods. In this study, confidence interval methods like Asymptotic Intervals, Conditional Intervals, Unconditional Interval, Score Intervals, and Nonparametric Methods Based on Relative Effects Intervals are used. Besides, as clinical application, data used in diagnostics study by Dickel et al. (2010) has been taken as a sample. Results. The results belonging to the alternative confidence interval methods for Nickel Sulfate, Potassium Dichromate, and Lanolin Alcohol are given as a table. Conclusion. While preferring the confidence interval methods, the researchers have to consider whether the case to be compared is single ratio or dependent binary ratio differences, the correlation coefficient between the rates in two dependent ratios and the sample sizes.

  9. ThOMAs: the other means of assessment.

    PubMed

    Williams, Andrew N; Debelle, Geoffrey D; Davies, Paul; Barrett, Tim G

    2005-02-01

    We describe a pilot study to investigate whether drawing "Thomas the Tank Engine" could be as effective a measure of developmental progress as the Goodenough-Harris Draw A Man test against the ThOMAs test (The Other Means of Assessment), with internal validation. The study included 95 children aged between 3 and 11 years of age, including a subgroup of 13 children with registered special needs from community and general pediatric clinics within Birmingham, UK, as a means of validation. There was no significant evidence that ThOMAS was either culturally or sex biased. Using regression analysis, nine items were found to correlate highly with actual age, and their total score gave a correlation of 0.563 with age. Adding further items did not increase this. After being converted into age-standardized scores, ThOMAS was as sensitive and specific as the Draw A Man test, and more so above a defined age-standardized threshold. This pilot study suggests that drawing Thomas the Tank Engine would appear to be as sensitive and specific a means of identifying children with special needs as the Goodenough-Harris Draw A Man test. The relatively small sample size means that further research is necessary to further define the age standardizations and to refine the ThOMAs test.

  10. Cross-Sectional Analysis of the Utility of Pulmonary Function Tests in Predicting Emphysema in Ever-Smokers

    PubMed Central

    Hesselbacher, Sean E.; Ross, Robert; Schabath, Matthew B.; Smith, E. O’Brian; Perusich, Sarah; Barrow, Nadia; Smithwick, Pamela; Mammen, Manoj J.; Coxson, Harvey; Krowchuk, Natasha; Corry, David B.; Kheradmand, Farrah

    2011-01-01

    Emphysema is largely an under-diagnosed medical condition that can exist in smokers in the absence of airway obstruction. We aimed to determine the sensitivity and specificity of pulmonary function tests (PFTs) in assessing emphysema using quantitative CT scans as the reference standard. We enrolled 224 ever-smokers (current or former) over the age of 40. CT of thorax was used to quantify the low attenuation area (% emphysema), and to measure the standardized airway wall thickness. PFTs were used individually and in combination to predict their ability to discriminate radiographic emphysema. Significant emphysema (>7%) was detected in 122 (54%) subjects. Twenty six (21%) emphysema subjects had no evidence of airflow obstruction (FEV1/FVC ratio <70%), while all subjects with >23% emphysema showed airflow obstruction. The sensitivity and specificity of spirometry for detecting radiographic emphysema were 79% and 75%, respectively. Standardized airway wall thickness was increased in subjects with airflow obstruction, but did not correlate with emphysema severity. In this cohort of lifetime ever-smokers, PFTs alone were inadequate for diagnosing emphysema. Airway wall thickness quantified by CT morphometry was associated with airflow limitation, but not with emphysema indicating that the heterogeneous nature of lung disease in smokers may represent distinct phenotypes. PMID:21655122

  11. Testing Pneumonia Vaccines in the Elderly: Determining a Case Definition for Pneumococcal Pneumonia in the Absence of a Gold Standard.

    PubMed

    Jokinen, Jukka; Snellman, Marja; Palmu, Arto A; Saukkoriipi, Annika; Verlant, Vincent; Pascal, Thierry; Devaster, Jeanne-Marie; Hausdorff, William P; Kilpi, Terhi M

    2018-06-01

    Clinical assessments of vaccines to prevent pneumococcal community-acquired pneumonia (CAP) require sensitive and specific case definitions, but there is no gold standard diagnostic test. To develop a new case definition suitable for vaccine efficacy studies, we applied latent class analysis (LCA) to the results from 7 diagnostic tests for pneumococcal etiology on clinical specimens from 323 elderly persons with radiologically confirmed pneumonia enrolled in the Finnish Community-Acquired Pneumonia Epidemiology study during 2005-2007. Compared with the conventional use of LCA, which is mainly to determine sensitivities and specificities of different tests, we instead used LCA as an appropriate instrument to predict the probability of pneumococcal etiology for each CAP case based on individual test profiles, and we used the predictions to minimize the sample size that would be needed for a vaccine efficacy trial. When compared with the conventional laboratory criteria of encapsulated pneumococci in culture, in blood culture or high-quality sputum culture, or urine antigen positivity, our optimized case definition for pneumococcal CAP resulted in a trial sample size that was almost 20,000 subjects smaller. We believe that the novel application of LCA detailed here to determine a case definition for pneumococcal CAP could also be similarly applied to other diseases without a gold standard.

  12. Development of a mobile application for oral cancer screening.

    PubMed

    Gomes, Mayra Sousa; Bonan, Paulo Rogério Ferreti; Ferreira, Vitor Yuri Nicolau; de Lucena Pereira, Laudenice; Correia, Ricardo João Cruz; da Silva Teixeira, Hélder Bruno; Pereira, Daniel Cláudio; Bonan, Paulo

    2017-01-01

    To develop a mobile application (app) for oral cancer screening. The app was developed using Android system version 4.4.2, with JAVA language. Information concerning sociodemographic data and risk factors for oral cancer development, e.g., tobacco and alcohol use, sun exposure and other contributing factors, such as unprotected oral sex, oral pain and denture use, were included. We surveyed a population at high risk for oral cancer development and then evaluated the sensitivity/specificity/accuracy and predictive values of clinical oral diagnosis between two blinded trained examiners, who used movies and data from the app, and in loco oral examination as gold-standard. A total of 55 individuals at high risk for oral cancer development were surveyed. Of these, 31% presented homogeneous/heterogeneous white lesions with potential of malignancy. The clinical diagnoses performed by the two examiners using videos were found to have sensitivity of 82%-100% (average 91%), specificity of 81%-100% (average 90.5%), and accuracy of 87.27%-95.54% (average 90.90%), as compared with the gold-standard. The Kappa agreement value between the gold-standard and the examiner with the best agreement was 0.597. Mobile apps including videos and data collection interfaces could be an interesting alternative in oral cancer research development.

  13. Cost-effectiveness of renin-guided treatment of hypertension.

    PubMed

    Smith, Steven M; Campbell, Jonathan D

    2013-11-01

    A plasma renin activity (PRA)-guided strategy is more effective than standard care in treating hypertension (HTN). However, its clinical implementation has been slow, presumably due in part to economic concerns. We estimated the cost effectiveness of a PRA-guided treatment strategy compared with standard care in a treated but uncontrolled HTN population. We estimated costs, quality-adjusted life years (QALYs), and the incremental cost-effectiveness ratio (ICER) of PRA-guided therapy compared to standard care using a state-transition simulation model with alternate patient characteristic scenarios and sensitivity analyses. Patient-specific inputs for the base case scenario, males average age 63 years, reflected best available data from a recent clinical trial of PRA-guided therapy. Transition probabilities were estimated using Framingham risk equations or derived from the literature; costs and utilities were derived from the literature. In the base case scenario for males, the lifetime discounted costs and QALYs were $23,648 and 12.727 for PRA-guided therapy and $22,077 and 12.618 for standard care, respectively. The base case ICER was $14,497/QALY gained. In alternative scenario analyses varying patient input parameters, the results were sensitive to age, gender, baseline systolic blood pressure, and the addition of cardiovascular risk factors. Univariate sensitivity analyses demonstrated that results were most sensitive to varying the treatment effect of PRA-guided therapy and the cost of the PRA test. Our results suggest that PRA-guided therapy compared with standard care increases QALYs and medical costs in most scenarios. PRA-guided therapy appears to be most cost effective in younger persons and those with more cardiovascular risk factors. © American Journal of Hypertension, Ltd 2013. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  14. 2-tiered antibody testing for early and late Lyme disease using only an immunoglobulin G blot with the addition of a VlsE band as the second-tier test.

    PubMed

    Branda, John A; Aguero-Rosenfeld, Maria E; Ferraro, Mary Jane; Johnson, Barbara J B; Wormser, Gary P; Steere, Allen C

    2010-01-01

    Standard 2-tiered immunoglobulin G (IgG) testing has performed well in late Lyme disease (LD), but IgM testing early in the illness has been problematic. IgG VlsE antibody testing, by itself, improves early sensitivity, but may lower specificity. We studied whether elements of the 2 approaches could be combined to produce a second-tier IgG blot that performs well throughout the infection. Separate serum sets from LD patients and control subjects were tested independently at 2 medical centers using whole-cell enzyme immunoassays and IgM and IgG immunoblots, with recombinant VlsE added to the IgG blots. The results from both centers were combined, and a new second-tier IgG algorithm was developed. With standard 2-tiered IgM and IgG testing, 31% of patients with active erythema migrans (stage 1), 63% of those with acute neuroborreliosis or carditis (stage 2), and 100% of those with arthritis or late neurologic involvement (stage 3) had positive results. Using new IgG criteria, in which only the VlsE band was scored as a second-tier test among patients with early LD (stage 1 or 2) and 5 of 11 IgG bands were required in those with stage 3 LD, 34% of patients with stage 1, 96% of those with stage 2, and 100% of those with stage 3 infection had positive responses. Both new and standard testing achieved 100% specificity. Compared with standard IgM and IgG testing, the new IgG algorithm (with VlsE band) eliminates the need for IgM testing; it provides comparable or better sensitivity, and it maintains high specificity.

  15. Double-labelling immunohistochemistry for MGMT and a “cocktail” of non-tumourous elements is a reliable, quick and easy technique for inferring methylation status in glioblastomas and other primary brain tumours

    PubMed Central

    2013-01-01

    Background Our aim was to develop a new protocol for MGMT immunohistochemistry with good agreement between observers and good correlation with molecular genetic tests of tumour methylation. We examined 40 primary brain tumours (30 glioblastomas and 10 oligodendroglial tumours) with our new technique, namely double-labelling immunohistochemistry for MGMT and a "cocktail" of non-tumour antigens (CD34, CD45 and CD68). We compared the results with single-labelling immunohistochemistry for MGMT and methylation-specific multiplex ligation-dependent probe amplification (MS-MLPA, a recognised molecular genetic technique which we applied as the gold-standard for the methylation status). Results Double-labelling immunohistochemistry for MGMT produced a visual separation of tumourous and non-tumourous elements on the same histological slide, making it quick and easy to determine whether tumour cell nuclei were MGMT-positive or MGMT-negative (and thereby infer the methylation status of the tumour). We found good agreement between observers (kappa 0.76) and within observer (kappa 0.84). Furthermore, double-labelling showed good specificity (80%), sensitivity (73.33%), positive predictive value (PPV, 83.33%) and negative predictive value (NPV, 68.75%) compared to MS-MLPA. Double-labelling was quicker and easier to assess than single-labelling and it outperformed quantitative computerised image analysis of MGMT single-labelling in terms of sensitivity, specificity, PPV and NPV. Conclusions Double-labelling immunohistochemistry for MGMT and a cocktail of non-tumourous elements provides a "one look" method for determining whether tumour cell nuclei are MGMT-positive or MGMT-negative. This can be used to infer the methylation status of the tumour. There is good observer agreement and good specificity, sensitivity, PPV and NPV compared to a molecular gold-standard. PMID:24252243

  16. Double-labelling immunohistochemistry for MGMT and a "cocktail" of non-tumourous elements is a reliable, quick and easy technique for inferring methylation status in glioblastomas and other primary brain tumours.

    PubMed

    Burke, Elinor; Grobler, Mariana; Elderfield, Kay; Bond, Frances; Crocker, Matthew; Taylor, Rohan; Bridges, Leslie R

    2013-06-10

    Our aim was to develop a new protocol for MGMT immunohistochemistry with good agreement between observers and good correlation with molecular genetic tests of tumour methylation. We examined 40 primary brain tumours (30 glioblastomas and 10 oligodendroglial tumours) with our new technique, namely double-labelling immunohistochemistry for MGMT and a "cocktail" of non-tumour antigens (CD34, CD45 and CD68). We compared the results with single-labelling immunohistochemistry for MGMT and methylation-specific multiplex ligation-dependent probe amplification (MS-MLPA, a recognised molecular genetic technique which we applied as the gold-standard for the methylation status). Double-labelling immunohistochemistry for MGMT produced a visual separation of tumourous and non-tumourous elements on the same histological slide, making it quick and easy to determine whether tumour cell nuclei were MGMT-positive or MGMT-negative (and thereby infer the methylation status of the tumour). We found good agreement between observers (kappa 0.76) and within observer (kappa 0.84). Furthermore, double-labelling showed good specificity (80%), sensitivity (73.33%), positive predictive value (PPV, 83.33%) and negative predictive value (NPV, 68.75%) compared to MS-MLPA. Double-labelling was quicker and easier to assess than single-labelling and it outperformed quantitative computerised image analysis of MGMT single-labelling in terms of sensitivity, specificity, PPV and NPV. Double-labelling immunohistochemistry for MGMT and a cocktail of non-tumourous elements provides a "one look" method for determining whether tumour cell nuclei are MGMT-positive or MGMT-negative. This can be used to infer the methylation status of the tumour. There is good observer agreement and good specificity, sensitivity, PPV and NPV compared to a molecular gold-standard.

  17. Digital obstructive arterial disease can be detected by laser Doppler measurements with high sensitivity and specificity.

    PubMed

    Mahe, Guillaume; Liedl, David A; McCarter, Charlene; Shepherd, Roger; Gloviczki, Peter; McPhail, Ian R; Rooke, Thom W; Wennberg, Paul W

    2014-04-01

    This study was conducted to determine the sensitivity and specificity of laser Doppler flowmetry (LDF) measurements for digital obstructive arterial disease (DOAD) using angiography as the reference standard and to compare the accuracy of different classical tests used to assess DOAD. Diagnosis of vascular abnormalities at the digital level is challenging. Angiography is the gold standard for assessment of DOAD but is invasive and expensive to perform. We performed a retrospective analysis of consecutive patients referred at Mayo Clinic (Rochester, Minn) for upper extremity arterial assessment during a 27-month period. Finger-brachial index, skin blood flow (in arbitrary units [a.u.]), and skin temperature (in degrees Celsius) were recorded in each digit on the pulp at baseline and after a thermal challenge test (hand placed in a thermal box at 47.0°C for 15 minutes). Angiogram analysis was blinded and performed by a radiologist using a vascularization scale ranging from 0 (no vessel) to 4 (normal). The receiver operating characteristic curve was used to define a specific cutoff point to detect DOAD. Twenty-two patients had LDF measurements and complete angiograms. A total of 185 digits were analyzed because some patients had only analysis of one hand. The best area under the curve (AUC) was 0.98 (range, 0.94-0.99) for postwarming skin blood flow, with a cutoff point of ≤206 a.u. This AUC was statistically different from AUCs of all the other tests (P < .01). Sensitivity and specificity were 93% (95% confidence interval, 85%-97%) and 96% (95% confidence interval, 90%-99%), respectively. LDF combined with a thermal challenge is highly accurate, safe, and noninvasive means to detect DOAD. Copyright © 2014 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  18. Validity of multislice computerized tomography for diagnosis of maxillofacial fractures using an independent workstation.

    PubMed

    Dos Santos, Denise Takehana; Costa e Silva, Adriana Paula Andrade; Vannier, Michael Walter; Cavalcanti, Marcelo Gusmão Paraiso

    2004-12-01

    The purpose of this study was to demonstrate the sensitivity and specificity of multislice computerized tomography (CT) for diagnosis of maxillofacial fractures following specific protocols using an independent workstation. The study population consisted of 56 patients with maxillofacial fractures who were submitted to a multislice CT. The original data were transferred to an independent workstation using volumetric imaging software to generate axial images and simultaneous multiplanar (MPR) and 3-dimensional (3D-CT) volume rendering reconstructed images. The images were then processed and interpreted by 2 examiners using the following protocols independently of each other: axial, MPR/axial, 3D-CT images, and the association of axial/MPR/3D images. The clinical/surgical findings were considered the gold standard corroborating the diagnosis of the fractures and their anatomic localization. The statistical analysis was carried out using validity and chi-squared tests. The association of axial/MPR/3D images indicated a higher sensitivity (range 95.8%) and specificity (range 99%) than the other methods regarding the analysis of all regions. CT imaging demonstrated high specificity and sensitivity for maxillofacial fractures. The association of axial/MPR/3D-CT images added important information in relationship to other CT protocols.

  19. Centralization as a predictor of provocation discography results in chronic low back pain, and the influence of disability and distress on diagnostic power.

    PubMed

    Laslett, Mark; Oberg, Birgitta; Aprill, Charles N; McDonald, Barry

    2005-01-01

    The "centralization phenomenon" (CP) is the progressive retreat of referred pain towards the spinal midline in response to repeated movement testing (a McKenzie evaluation). A previous study suggested that it may have utility in the clinical diagnosis of discogenic pain and may assist patient selection for discography and specific treatments for disc pain. Estimation of the diagnostic predictive power of centralization and the influence of disability and patient distress on diagnostic performance, using provocation discography as a criterion standard for diagnosis, in chronic low back pain patients. This study was a prospective, blinded, concurrent, reference standard-related validity design carried out in a private radiology clinic specializing in diagnosis of chronic spinal pain. Consecutive patients with persistent low back pain were referred to the study clinic by orthopedists and other medical specialists for interventional radiological diagnostic procedures. Patients were typically disabled and displayed high levels of psychosocial distress. The sample included patients with previous lumbar surgery, and most had unsuccessful conservative therapies previously. results of provocation discography. The CP. Psychometric evaluation: Roland-Morris, Zung, Modified Somatic Perception questionnaires, Distress Risk Assessment Method, and 100-mm visual analog scales for pain intensity. Patients received a single physical therapy examination, followed by lumbar provocation discography. Sensitivity, specificity, and likelihood ratios of the CP were estimated in the group as a whole and in subgroups defined by psychometric measures. A total of 107 patients received the clinical examination and discography at two or more levels and post-discography computed tomography. Thirty-eight could not tolerate a full physical examination and were excluded from the main analysis. Disability and pain intensity ratings were high, and distress was common. Sensitivity, specificity, and positive likelihood ratios for centralization observed during repeated movement testing for pain distribution and intensity changes were 40%, 94%, and 6.9 respectively. In the presence of severe disability, sensitivity, specificity, and positive likelihood ratios were 46%, 80%, 3.2 and for distress, 45%, 89%, 4.1. In the subgroups with moderate, minimal, or no disability, sensitivity and specificity were 37%, 100% and for no or minimal distress 35%, 100%. Centralization is highly specific to positive discography but specificity is reduced in the presence of severe disability or psychosocial distress.

  20. Early, Accurate Diagnosis and Early Intervention in Cerebral Palsy: Advances in Diagnosis and Treatment.

    PubMed

    Novak, Iona; Morgan, Cathy; Adde, Lars; Blackman, James; Boyd, Roslyn N; Brunstrom-Hernandez, Janice; Cioni, Giovanni; Damiano, Diane; Darrah, Johanna; Eliasson, Ann-Christin; de Vries, Linda S; Einspieler, Christa; Fahey, Michael; Fehlings, Darcy; Ferriero, Donna M; Fetters, Linda; Fiori, Simona; Forssberg, Hans; Gordon, Andrew M; Greaves, Susan; Guzzetta, Andrea; Hadders-Algra, Mijna; Harbourne, Regina; Kakooza-Mwesige, Angelina; Karlsson, Petra; Krumlinde-Sundholm, Lena; Latal, Beatrice; Loughran-Fowlds, Alison; Maitre, Nathalie; McIntyre, Sarah; Noritz, Garey; Pennington, Lindsay; Romeo, Domenico M; Shepherd, Roberta; Spittle, Alicia J; Thornton, Marelle; Valentine, Jane; Walker, Karen; White, Robert; Badawi, Nadia

    2017-09-01

    Cerebral palsy describes the most common physical disability in childhood and occurs in 1 in 500 live births. Historically, the diagnosis has been made between age 12 and 24 months but now can be made before 6 months' corrected age. To systematically review best available evidence for early, accurate diagnosis of cerebral palsy and to summarize best available evidence about cerebral palsy-specific early intervention that should follow early diagnosis to optimize neuroplasticity and function. This study systematically searched the literature about early diagnosis of cerebral palsy in MEDLINE (1956-2016), EMBASE (1980-2016), CINAHL (1983-2016), and the Cochrane Library (1988-2016) and by hand searching. Search terms included cerebral palsy, diagnosis, detection, prediction, identification, predictive validity, accuracy, sensitivity, and specificity. The study included systematic reviews with or without meta-analyses, criteria of diagnostic accuracy, and evidence-based clinical guidelines. Findings are reported according to the PRISMA statement, and recommendations are reported according to the Appraisal of Guidelines, Research and Evaluation (AGREE) II instrument. Six systematic reviews and 2 evidence-based clinical guidelines met inclusion criteria. All included articles had high methodological Quality Assessment of Diagnostic Accuracy Studies (QUADAS) ratings. In infants, clinical signs and symptoms of cerebral palsy emerge and evolve before age 2 years; therefore, a combination of standardized tools should be used to predict risk in conjunction with clinical history. Before 5 months' corrected age, the most predictive tools for detecting risk are term-age magnetic resonance imaging (86%-89% sensitivity), the Prechtl Qualitative Assessment of General Movements (98% sensitivity), and the Hammersmith Infant Neurological Examination (90% sensitivity). After 5 months' corrected age, the most predictive tools for detecting risk are magnetic resonance imaging (86%-89% sensitivity) (where safe and feasible), the Hammersmith Infant Neurological Examination (90% sensitivity), and the Developmental Assessment of Young Children (83% C index). Topography and severity of cerebral palsy are more difficult to ascertain in infancy, and magnetic resonance imaging and the Hammersmith Infant Neurological Examination may be helpful in assisting clinical decisions. In high-income countries, 2 in 3 individuals with cerebral palsy will walk, 3 in 4 will talk, and 1 in 2 will have normal intelligence. Early diagnosis begins with a medical history and involves using neuroimaging, standardized neurological, and standardized motor assessments that indicate congruent abnormal findings indicative of cerebral palsy. Clinicians should understand the importance of prompt referral to diagnostic-specific early intervention to optimize infant motor and cognitive plasticity, prevent secondary complications, and enhance caregiver well-being.

  1. Early driver fatigue detection from electroencephalography signals using artificial neural networks.

    PubMed

    King, L M; Nguyen, H T; Lal, S K L

    2006-01-01

    This paper describes a driver fatigue detection system using an artificial neural network (ANN). Using electroencephalogram (EEG) data sampled from 20 professional truck drivers and 35 non professional drivers, the time domain data are processed into alpha, beta, delta and theta bands and then presented to the neural network to detect the onset of driver fatigue. The neural network uses a training optimization technique called the magnified gradient function (MGF). This technique reduces the time required for training by modifying the standard back propagation (SBP) algorithm. The MGF is shown to classify professional driver fatigue with 81.49% accuracy (80.53% sensitivity, 82.44% specificity) and non-professional driver fatigue with 83.06% accuracy (84.04% sensitivity and 82.08% specificity).

  2. Automated imaging technologies for the diagnosis of glaucoma: a comparative diagnostic study for the evaluation of the diagnostic accuracy, performance as triage tests and cost-effectiveness (GATE study).

    PubMed

    Azuara-Blanco, Augusto; Banister, Katie; Boachie, Charles; McMeekin, Peter; Gray, Joanne; Burr, Jennifer; Bourne, Rupert; Garway-Heath, David; Batterbury, Mark; Hernández, Rodolfo; McPherson, Gladys; Ramsay, Craig; Cook, Jonathan

    2016-01-01

    Many glaucoma referrals from the community to hospital eye services are unnecessary. Imaging technologies can potentially be useful to triage this population. To assess the diagnostic performance and cost-effectiveness of imaging technologies as triage tests for identifying people with glaucoma. Within-patient comparative diagnostic accuracy study. Markov economic model comparing the cost-effectiveness of a triage test with usual care. Secondary care. Adults referred from the community to hospital eye services for possible glaucoma. Heidelberg Retinal Tomography (HRT), including two diagnostic algorithms, glaucoma probability score (HRT-GPS) and Moorfields regression analysis (HRT-MRA); scanning laser polarimetry [glaucoma diagnostics (GDx)]; and optical coherence tomography (OCT). The reference standard was clinical examination by a consultant ophthalmologist with glaucoma expertise including visual field testing and intraocular pressure (IOP) measurement. (1) Diagnostic performance of imaging, using data from the eye with most severe disease. (2) Composite triage test performance (imaging test, IOP measurement and visual acuity measurement), using data from both eyes, in correctly identifying clinical management decisions, that is 'discharge' or 'do not discharge'. Outcome measures were sensitivity, specificity and incremental cost per quality-adjusted life-year (QALY). Data from 943 of 955 participants were included in the analysis. The average age was 60.5 years (standard deviation 13.8 years) and 51.1% were females. Glaucoma was diagnosed by the clinician in at least one eye in 16.8% of participants; 37.9% of participants were discharged after the first visit. Regarding diagnosing glaucoma, HRT-MRA had the highest sensitivity [87.0%, 95% confidence interval (CI) 80.2% to 92.1%] but the lowest specificity (63.9%, 95% CI 60.2% to 67.4%) and GDx had the lowest sensitivity (35.1%, 95% CI 27.0% to 43.8%) but the highest specificity (97.2%, 95% CI 95.6% to 98.3%). HRT-GPS had sensitivity of 81.5% (95% CI 73.9% to 87.6%) and specificity of 67.7% (95% CI 64.2% to 71.2%) and OCT had sensitivity of 76.9% (95% CI 69.2% to 83.4%) and specificity of 78.5% (95% CI 75.4% to 81.4%). Regarding triage accuracy, triage using HRT-GPS had the highest sensitivity (86.0%, 95% CI 82.8% to 88.7%) but the lowest specificity (39.1%, 95% CI 34.0% to 44.5%), GDx had the lowest sensitivity (64.7%, 95% CI 60.7% to 68.7%) but the highest specificity (53.6%, 95% CI 48.2% to 58.9%). Introducing a composite triage station into the referral pathway to identify appropriate referrals was cost-effective. All triage strategies resulted in a cost reduction compared with standard care (consultant-led diagnosis) but with an associated reduction in effectiveness. GDx was the least costly and least effective strategy. OCT and HRT-GPS were not cost-effective. Compared with GDx, the cost per QALY gained for HRT-MRA is £22,904. The cost per QALY gained with current practice is £156,985 compared with HRT-MRA. Large savings could be made by implementing HRT-MRA but some benefit to patients will be forgone. The results were sensitive to the triage costs. Automated imaging can be effective to aid glaucoma diagnosis among individuals referred from the community to hospital eye services. A model of care using a triage composite test appears to be cost-effective. There are uncertainties about glaucoma progression under routine care and the cost of providing health care. The acceptability of implementing a triage test needs to be explored. The National Institute for Health Research Health Technology Assessment programme.

  3. Comparing multifocal VEP and standard automated perimetry in high-risk ocular hypertension and early glaucoma.

    PubMed

    Fortune, Brad; Demirel, Shaban; Zhang, Xian; Hood, Donald C; Patterson, Emily; Jamil, Annisa; Mansberger, Steven L; Cioffi, George A; Johnson, Chris A

    2007-03-01

    To compare the diagnostic performance of multifocal visual evoked potential (mfVEP) and standard automated perimetry (SAP), in eyes with high-risk ocular hypertension or early glaucoma. Both eyes of 185 individuals with high-risk ocular hypertension or early glaucoma were evaluated. Subjects ranged in age from 37 to 87 (mean +/- SD: 61 +/- 11 years). Pattern-reversal mfVEPs were obtained by using VERIS (Electro-Diagnostic Imaging, San Mateo, CA) with a four-electrode array and were analyzed with custom software. SAP visual fields (SITA-standard; Carl Zeiss Meditec, Inc., Dublin, CA) were obtained within 22.3 +/- 27.0 days of the mfVEP. Stereo disc photographs and Heidelberg Retina Tomograph (HRT) images were obtained during one visit, which was within 24.8 +/- 50.4 days of the mfVEP and 33.1 +/- 62.9 days of the SAP visual field. Abnormalities on the mfVEP were defined by using a variety of cluster criteria: SAP with pattern standard deviation (PSD) P

  4. Impact of the hard-coded parameters on the hydrologic fluxes of the land surface model Noah-MP

    NASA Astrophysics Data System (ADS)

    Cuntz, Matthias; Mai, Juliane; Samaniego, Luis; Clark, Martyn; Wulfmeyer, Volker; Attinger, Sabine; Thober, Stephan

    2016-04-01

    Land surface models incorporate a large number of processes, described by physical, chemical and empirical equations. The process descriptions contain a number of parameters that can be soil or plant type dependent and are typically read from tabulated input files. Land surface models may have, however, process descriptions that contain fixed, hard-coded numbers in the computer code, which are not identified as model parameters. Here we searched for hard-coded parameters in the computer code of the land surface model Noah with multiple process options (Noah-MP) to assess the importance of the fixed values on restricting the model's agility during parameter estimation. We found 139 hard-coded values in all Noah-MP process options, which are mostly spatially constant values. This is in addition to the 71 standard parameters of Noah-MP, which mostly get distributed spatially by given vegetation and soil input maps. We performed a Sobol' global sensitivity analysis of Noah-MP to variations of the standard and hard-coded parameters for a specific set of process options. 42 standard parameters and 75 hard-coded parameters were active with the chosen process options. The sensitivities of the hydrologic output fluxes latent heat and total runoff as well as their component fluxes were evaluated. These sensitivities were evaluated at twelve catchments of the Eastern United States with very different hydro-meteorological regimes. Noah-MP's hydrologic output fluxes are sensitive to two thirds of its standard parameters. The most sensitive parameter is, however, a hard-coded value in the formulation of soil surface resistance for evaporation, which proved to be oversensitive in other land surface models as well. Surface runoff is sensitive to almost all hard-coded parameters of the snow processes and the meteorological inputs. These parameter sensitivities diminish in total runoff. Assessing these parameters in model calibration would require detailed snow observations or the calculation of hydrologic signatures of the runoff data. Latent heat and total runoff exhibit very similar sensitivities towards standard and hard-coded parameters in Noah-MP because of their tight coupling via the water balance. It should therefore be comparable to calibrate Noah-MP either against latent heat observations or against river runoff data. Latent heat and total runoff are sensitive to both, plant and soil parameters. Calibrating only a parameter sub-set of only soil parameters, for example, thus limits the ability to derive realistic model parameters. It is thus recommended to include the most sensitive hard-coded model parameters that were exposed in this study when calibrating Noah-MP.

  5. [Significance of 2-hour blood glucose after standardized steamed bread meal in diabetic screening].

    PubMed

    Liu, Yongquan; Tian, Hui; Fang, Fusheng; Xiao, Haiying; Lu, Yanhui; Shao, Yinghong; Li, Chunlin

    2014-05-13

    To explore the significance of 2-hour blood glucose after standardized steamed bread meal (SB-2 hBG) in diabetic screening. A retrospective study was conducted for diabetic screening data of annual check-up at PLA General Hospital from May 1996 to June 2002. And 100 g standardized steamed bread meal test was performed for non-diabetic subjects. Those subjects with SB-2 h BG ≥ 7.2 mmol/L underwent a 75 g oral glucose tolerance test (OGTT) within 2 weeks to determine whether the diagnosis of diabetes mellitus (DM) could be established (WHO, 1985, 1999, Diagnostic Criteria for Diabetes). By extracting the data for 7 consecutive years, we analyzed the significance and the cut-off point of SB-2 hBG in the diagnosis of DM and investigated the changes of blood glucose curves in different glucose tolerance status after different glucose loading tests. A total of 3 343 subjects with complete information were recruited. There were 3 101 males and 242 females with an age range of 40-94 years. According to the results of OGTT, 429 (12.8%) subjects were diagnosed as DM, 1 405 (42.1%) were diagnosed as impaired glucose regulation (IGR) and 1 509(45.1%) had normal glucose tolerance (NGT).With a deterioration of glucose tolerance status, the difference between SB-2 hBG and OGTT-2 hBG increased gradually in 3 group (P < 0.01), namely the NGT group 1.7 (0.8-2.8) mmol/L, IGR group -0.4 (-1.2-0.6) mmol/L, DM group -2.7(-3.8-1.1) mmol/L. The cut-off points of FBG for the diagnosis of IGR and DM were 5.3 (sensitivity of 46.2%, specificity of 68.5%) and 5.6 (sensitivity of 57.4%, specificity of 76.4%) mmol/L respectively. The cut-off points of SB-2 h BG were 8.2 mmol/L for the diagnosis of IGR (sensitivity of 63.8%, specificity of 59.9%) and 9.2 mmol/L for the diagnosis of DM (sensitivity of 66.4%, specificity of 76.4%).If the cut-off point of SB-2 h BG was set at 7.2 mmol/L, the diagnostic specificity became quite low.However, at 11.1 mmol/L, the sensitivity was 31.5% and the specificity 95.7% for the diagnosis of DM. The coincidences of cut-off points of FBG and SB-2 hBG for the diagnosis of IGR and DM were equal (P > 0.05).When the cut-off point of SB-2 h BG was set at 7.8 mmol/L, the sensitivity was 77.4% and the specificity 41.8% for the diagnosis of IGR. And it was much better than FBG at 5.6 mmol/L (P < 0.01). With a deterioration of glucose tolerance, the difference between SB-2 hBG and OGTT-2 hBG increases gradually. Compared to the diagnostic criteria of OGTT, the optimal cut-off points for the diagnosis of IGR and DM were 5.3 vs 5.6 mmol/L for FBG and 8.2 vs 9.2 mmol/L for SB-2 hBG respectively.For diabetic screening in middle-aged and elders, the cut-off points of FBG at 5.3 mmol/L and SB-2 hBG at 7.8 mmol/L are indicators for further OGTT.

  6. Affirm VPIII microbial identification test can be used to detect gardnerella vaginalis, Candida albicans and trichomonas vaginalis microbial infections in Korean women.

    PubMed

    Byun, Seung Won; Park, Yeon Joon; Hur, Soo Young

    2016-04-01

    The aim of this study was to compare Affirm VPIII Microbial Identification Test results for Korean women to those obtained for Gardnerella vaginalis through Nugent score, Candida albicans based on vaginal culture and Trichomonas vaginalis based on wet smear diagnostic standards. Study participants included 195 women with symptomatic or asymptomatic vulvovaginitis under hospital obstetric or gynecologic care. A definite diagnosis was made based on Nugent score for Gardnerella, vaginal culture for Candida and wet prep for Trichomonas vaginalis. Affirm VPIII Microbial Identification Test results were then compared to diagnostic standard results. Of the 195 participants, 152 were symptomatic, while 43 were asymptomatic. Final diagnosis revealed 68 (37.87%) cases of Gardnerella, 29 (14.87%) cases of Candida, one (0.51%) case of Trichomonas, and 10 (5.10%) cases of mixed infections. The detection rates achieved by each detection method (Affirm assay vs diagnostic standard) for Gardnerella and Candida were not significantly different (33.33% vs 34.8% for Gardnerella, 13.33% vs 14.87% for Candida, respectively). The sensitivity and specificity of the Affirm test for Gardnerella compared to the diagnostic standard were 75.0% and 88.98%, respectively. For Candida, the sensitivity and specificity of the Affirm test compared to the diagnostic standard were 82.76% and 98.80%, respectively. The number of Trichomonas cases was too small (1 case) to be statistically analyzed. The Affirm test is a quick tool that can help physicians diagnose and treat patients with infectious vaginitis at the point of care. © 2016 Japan Society of Obstetrics and Gynecology.

  7. THE ACCURACY OF DIGITAL-VIDEO RETINAL IMAGING TO SCREEN FOR DIABETIC RETINOPATHY: AN ANALYSIS OF TWO DIGITAL-VIDEO RETINAL IMAGING SYSTEMS USING STANDARD STEREOSCOPIC SEVEN-FIELD PHOTOGRAPHY AND DILATED CLINICAL EXAMINATION AS REFERENCE STANDARDS

    PubMed Central

    Lawrence, Mary Gilbert

    2004-01-01

    ABSTRACT Purpose To evaluate the accuracy of two digital-video retinal imaging (DVRI) systems to detect diabetic retinopathy. Methods A prospective, masked, technology assessment was conducted for two DVRI systems at a tertiary care Veterans Affairs Medical Center. Group A (n = 151 patients) was imaged with a 640 × 480 resolution system and group B (n = 103 patients) with an 800 × 600 resolution system. Four retinal evaluations were performed on each patient: DVRI with undilated pupils using one imaging field (U-DVRI), DVRI with dilated pupils using three imaging fields (D-DVRI), dilated clinical examination, and Early Treatment Diabetic Retinopathy Study stereoscopic seven-field photography (ETDRS-P). Two analyses of accuracy were conducted, one using ETDRS-P as a “gold standard” (ETDRS-GS) and one using dilated clinical examination as a “gold standard” (C-GS). Results For group A, using the ETDRS-GS, sensitivities of U-DVRI and D-DVRI were 0.66 and 0.66; specificities of U-DVRI and D-DVRI were 0.66 and 0.86. Using the C-GS, sensitivities of U-DVRI and D-DVRI were 0.79 and 0.80; specificities of U-DVRI and D-DVRI were 0.68 and 0.85. For group B, using the ETDRS-GS, sensitivities of U-DVRI and D-DVRI were 0.76 and 0.85; specificities of U-DVRI and D-DVRI were 0.45 and 0.80. Using the C-GS, sensitivities of U-DVRI and D-DVRI were 0.81 and 0.87; specificities of U-DVRI and D-DVRI were 0.45 and 0.69. For both groups, dilation significantly improved specificities. Conclusions The 800 × 600 resolution DVRI system offers an accurate method of detecting diabetic retinopathy, provided there is adequate pupillary dilation and three retinal images are taken. DVRI technology may help facilitate retinal screenings of growing diabetic populations. PMID:15747766

  8. Diagnostic accuracy of three monoclonal stool tests in a large series of untreated Helicobacter pylori infected patients.

    PubMed

    Lario, Sergio; Ramírez-Lázaro, María José; Montserrat, Antònia; Quílez, María Elisa; Junquera, Félix; Martínez-Bauer, Eva; Sanfeliu, Isabel; Brullet, Enric; Campo, Rafael; Segura, Ferran; Calvet, Xavier

    2016-06-01

    Immunochromatographic tests need to be improved in order to enhance their reliability. Recently, several new kits have appeared on the market. The objective was to evaluate the diagnostic accuracy of three monoclonal rapid stool tests - the new Uni-Gold™ H.pylori Antigen (Trinity Biotech, Ireland), the RAPID Hp StAR (Oxoid Ltd., UK) and the ImmunoCard STAT! HpSA (Meridian Diagnostics, USA) - for detecting H. pylori infection prior to eradication treatment. Diagnostic accuracy (sensitivity and specificity) and reliability (concordance between observers) were evaluated in 250 untreated consecutive dyspeptic patients. The gold standard for diagnosing H. pylori infection was defined as the concordance of two or more of rapid urease test (RUT), histopathology and urease breath test (UBT) or positive culture in isolation. Readings of immunochromatographic tests were performed by two different observers. Sensitivity, specificity, positive and negative predictive values and 95% confidence intervals were calculated. Sensitivity and specificity were compared using the McNemar test. The three tests showed a good correlation, with Kappa values>0.9. RAPID Hp StAR had a sensitivity of 91%-92% and a specificity ranging from 77% to 85%. Its sensitivity was higher than that of Uni-Gold™ H.pylori Antigen and ImmunoCard STAT! HpSA (p<0.01). Uni-Gold™ H.pylori Antigen kit showed a sensitivity of 83%, similar to ImmunoCard STAT! HpSA. Specificity of Uni-Gold™ H.pylori Antigen approached 90% (87-89%) and was superior to that of RAPID Hp StAR (p<0.01). Uni-Gold™ H.pylori Antigen and ImmunoCard STAT! HpSA present similar levels of diagnostic accuracy. RAPID Hp StAR was the most sensitive but less reliable of the three immunochromatographic stool tests. None are as accurate and reliable as UBT, RUT and histology. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  9. Genotypic, Phenotypic and Clinical Validation of GeneXpert in Extra-Pulmonary and Pulmonary Tuberculosis in India

    PubMed Central

    Singh, Urvashi B.; Pandey, Pooja; Mehta, Girija; Bhatnagar, Anuj K.; Mohan, Anant; Goyal, Vinay; Ahuja, Vineet; Ramachandran, Ranjani; Sachdeva, Kuldeep S.; Samantaray, Jyotish C.

    2016-01-01

    Background Newer molecular diagnostics have brought paradigm shift in early diagnosis of tuberculosis [TB]. WHO recommended use of GeneXpert MTB/RIF [Xpert] for Extra-pulmonary [EP] TB; critics have since questioned its efficiency. Methods The present study was designed to assess the performance of GeneXpert in 761 extra-pulmonary and 384 pulmonary specimens from patients clinically suspected of TB and compare with Phenotypic, Genotypic and Composite reference standards [CRS]. Results Comparison of GeneXpert results to CRS, demonstrated sensitivity of 100% and 90.68%, specificity of 100% and 99.62% for pulmonary and extra-pulmonary samples. On comparison with culture, sensitivity for Rifampicin [Rif] resistance detection was 87.5% and 81.82% respectively, while specificity was 100% for both pulmonary and extra-pulmonary TB. On comparison to sequencing of rpoB gene [Rif resistance determining region, RRDR], sensitivity was respectively 93.33% and 90% while specificity was 100% in both pulmonary and extra-pulmonary TB. GeneXpert assay missed 533CCG mutation in one sputum and dual mutation [517 & 519] in one pus sample, detected by sequencing. Sequencing picked dual mutation [529, 530] in a sputum sample sensitive to Rif, demonstrating, not all RRDR mutations lead to resistance. Conclusions Current study reports observations in a patient care setting in a high burden region, from a large collection of pulmonary and extra-pulmonary samples and puts to rest questions regarding sensitivity, specificity, detection of infrequent mutations and mutations responsible for low-level Rif resistance by GeneXpert. Improvements in the assay could offer further improvement in sensitivity of detection in different patient samples; nevertheless it may be difficult to improve sensitivity of Rif resistance detection if only one gene is targeted. Assay specificity was high both for TB detection and Rif resistance detection. Despite a few misses, the assay offers major boost to early diagnosis of TB and MDR-TB, in difficult to diagnose pauci-bacillary TB. PMID:26894283

  10. Unenhanced low-dose versus standard-dose CT localization in patients with upper urinary calculi for minimally invasive percutaneous nephrolithotomy (MPCNL)

    PubMed Central

    Licheng, Jiang; Yidong, Fan; Ping, Wang; Keqiang, Yan; Xueting, Wang; Yingchen, Zhang; Lei, Gao; Jiyang, Ding; Zhonghua, Xu

    2014-01-01

    Background & objectives: With the ethical concern about the dose of CT scan and wide use of CT in protocol of suspected renal colic, more attention has been paid to low dose CT. The aim of the present study was to make a comparison of unenhanced low-dose spiral CT localization with unenhanced standard-dose spiral CT in patients with upper urinary tract calculi for minimally invasive percutaneous nephrolithotomy (MPCNL) treatment. Methods: Twenty eight patients with ureter and renal calculus, preparing to take MPCNL, underwent both abdominal low-dose CT (25 mAs) and standard-dose CT (100 mAs). Low-dose CT and standard-dose CT were independently evaluated for the characterization of renal/ureteral calculi, perirenal adjacent organs, blood vessels, indirect signs of renal or ureteral calculus (renal enlargement, pyeloureteral dilatation), and the indices of localization (percutaneous puncture angulation and depth) used in the MPCNL procedure. Results: In all 28 patients, low-dose CT was 100 per cent coincidence 100 per cent sensitive and 100 per cent specific for depicting the location of the renal and ureteral calculus, renal enlargement, pyeloureteral dilatation, adjacent organs, and the presumptive puncture point and a 96.3 per cent coincidence 96 per cent sensitivity and 93 per cent specificity for blood vessel signs within the renal sinus, and with an obvious lower radiation exposure for patients when compared to standard-dose CT (P<0.05). The indices of puncture depth, puncture angulation, and maximum calculus transverse diameter on the axial surface showed no significant difference between the two doses of CT scans, with a significant variation in calculus visualization slice numbers (P<0.05). Interpretation & conclusions: Our findings show that unenhanced low-dose CT achieves a sensitivity and accuracy similar to that of standard-dose CT in assessing the localization of renal ureteral calculus and adjacent organs conditions and identifying the maximum calculus transverse diameter on the axial surface, percutaneous puncture depth, and angulation in patients, with a significant lower radiation exposure, who are to be treated by MPCNL, and can be used as an alternative localization method. PMID:24820832

  11. Unenhanced low-dose versus standard-dose CT localization in patients with upper urinary calculi for minimally invasive percutaneous nephrolithotomy (MPCNL).

    PubMed

    Licheng, Jiang; Yidong, Fan; Ping, Wang; Keqiang, Yan; Xueting, Wang; Yingchen, Zhang; Lei, Gao; Jiyang, Ding; Zhonghua, Xu

    2014-03-01

    With the ethical concern about the dose of CT scan and wide use of CT in protocol of suspected renal colic, more attention has been paid to low dose CT. The aim of the present study was to make a comparison of unenhanced low-dose spiral CT localization with unenhanced standard-dose spiral CT in patients with upper urinary tract calculi for minimally invasive percutaneous nephrolithotomy (MPCNL) treatment. Twenty eight patients with ureter and renal calculus, preparing to take MPCNL, underwent both abdominal low-dose CT (25 mAs) and standard-dose CT (100 mAs). Low-dose CT and standard-dose CT were independently evaluated for the characterization of renal/ureteral calculi, perirenal adjacent organs, blood vessels, indirect signs of renal or ureteral calculus (renal enlargement, pyeloureteral dilatation), and the indices of localization (percutaneous puncture angulation and depth) used in the MPCNL procedure. In all 28 patients, low-dose CT was 100 per cent coincidence 100 per cent sensitive and 100 per cent specific for depicting the location of the renal and ureteral calculus, renal enlargement, pyeloureteral dilatation, adjacent organs, and the presumptive puncture point and a 96.3 per cent coincidence 96 per cent sensitivity and 93 per cent specificity for blood vessel signs within the renal sinus, and with an obvious lower radiation exposure for patients when compared to standard-dose CT (P<0.05). The indices of puncture depth, puncture angulation, and maximum calculus transverse diameter on the axial surface showed no significant difference between the two doses of CT scans, with a significant variation in calculus visualization slice numbers (P<0.05). Our findings show that unenhanced low-dose CT achieves a sensitivity and accuracy similar to that of standard-dose CT in assessing the localization of renal ureteral calculus and adjacent organs conditions and identifying the maximum calculus transverse diameter on the axial surface, percutaneous puncture depth, and angulation in patients, with a significant lower radiation exposure, who are to be treated by MPCNL, and can be used as an alternative localization method.

  12. Real-Time Elicitation of Moral Emotions Using a Prejudice Paradigm

    PubMed Central

    Fourie, Melike M.; Kilchenmann, Nadine; Malcolm-Smith, Susan; Thomas, Kevin G. F. 

    2012-01-01

    Moral emotions are critically important in guiding appropriate social conduct. Empirical investigation of these emotions remains a challenge, however, because of the difficulty in eliciting them reliably in controlled settings. Here we describe a novel prejudice paradigm that aimed to elicit both negatively and positively valenced moral emotions in real-time. Low-prejudice females (N = 46) who met highly specific demographic and personality-based screening criteria completed a series of Implicit Association Tests (IATs). Feedback following these IATs was pre-programmed to either endorse participants’ non-prejudiced self-standards (positive condition), or to contradict their self-standards (negative condition), in response to sensitive social topics. Neutral condition IATs reflected participants’ attitudes toward non-sensitive social topics. Results demonstrated that the IATs were successful in eliciting moral-positive emotions (satisfaction and pride) and moral-negative emotions (primarily guilt). In addition, participants high in self-reported punishment sensitivity, as assessed by the Behavioral Inhibition System (BIS) scale, reported greater guilt. PMID:22888322

  13. Real-time elicitation of moral emotions using a prejudice paradigm.

    PubMed

    Fourie, Melike M; Kilchenmann, Nadine; Malcolm-Smith, Susan; Thomas, Kevin G F

    2012-01-01

    Moral emotions are critically important in guiding appropriate social conduct. Empirical investigation of these emotions remains a challenge, however, because of the difficulty in eliciting them reliably in controlled settings. Here we describe a novel prejudice paradigm that aimed to elicit both negatively and positively valenced moral emotions in real-time. Low-prejudice females (N = 46) who met highly specific demographic and personality-based screening criteria completed a series of Implicit Association Tests (IATs). Feedback following these IATs was pre-programmed to either endorse participants' non-prejudiced self-standards (positive condition), or to contradict their self-standards (negative condition), in response to sensitive social topics. Neutral condition IATs reflected participants' attitudes toward non-sensitive social topics. Results demonstrated that the IATs were successful in eliciting moral-positive emotions (satisfaction and pride) and moral-negative emotions (primarily guilt). In addition, participants high in self-reported punishment sensitivity, as assessed by the Behavioral Inhibition System (BIS) scale, reported greater guilt.

  14. Standard-b-Value Versus Low-b-Value Diffusion-Weighted Imaging in Hepatic Lesion Discrimination: A Meta-analysis.

    PubMed

    Xiong, Hui; Zeng, Yuan-Lin

    2016-01-01

    We sought to determine the comparative diagnostic performance of standard-b-value (500-1000s/mm) versus low-b-value (≤500 s/mm) diffusion-weighted imaging (DWI) in the discrimination of hepatic lesions. A total of 1775 hepatic malignant lesions and 1120 benign hepatic lesions from 21 studies were included. (1) The global sensitivity was 0.86 (95% confidence interval [CI], 0.847-0.879), the specificity was 0.82 (95% CI, 0.797-0.842), the positive likelihood ratio (PLR) was 6.234 (95% CI, 4.260-9.123), the negative likelihood ratio (NLR) was 0.175 (95% CI, 0.135-0.227), and diagnostic odds ratio (DOR) was 42.836 (95% CI, 24.134-76.031). The area under the curve (AUC) and Q* index were 0.93 and 0.87. Publication bias was not present (P > 0.05). (2)The sensitivity of a subgroup meta-analysis of standard-b-value DWI was 0.858 (95% CI, 0.835-0.880), the specificity was 0.836 (95% CI, 0.807-0.863), the PLR was 6.527 (95% CI, 3.857-11.046), the NLR was 0.168 (95% CI, 0.123-0.239), and the DOR was 49.716 (95% CI, 22.897-107.98). The AUC and Q* index were 0.941 and 0.88. (3)The sensitivity of a subgroup meta-analysis of low-b-value DWI was 0.87 (95% CI, 0.84-0.89), the specificity was 0.80 (95% CI, 0.76-0.83), the PLR was 6.22 (95% CI, 3.29-11.76), the NLR was 0.19 (95% CI, 0.12-0.29), and the DOR was 37.14 (95% CI, 14.80-93.18). The AUC and Q* index were 0.922 and 0.86. Hepatic DWI is useful in differentiating between malignant and benign hepatic lesions. Standard-b-value DWI displayed an overall superior diagnostic accuracy over low-b-value DWI. Further trials needed to determine whether increasing b values beyond 1000 s/mm affects the diagnostic accuracy of hepatic lesion discrimination.

  15. The impact of standard and hard-coded parameters on the hydrologic fluxes in the Noah-MP land surface model

    NASA Astrophysics Data System (ADS)

    Cuntz, Matthias; Mai, Juliane; Samaniego, Luis; Clark, Martyn; Wulfmeyer, Volker; Branch, Oliver; Attinger, Sabine; Thober, Stephan

    2016-09-01

    Land surface models incorporate a large number of process descriptions, containing a multitude of parameters. These parameters are typically read from tabulated input files. Some of these parameters might be fixed numbers in the computer code though, which hinder model agility during calibration. Here we identified 139 hard-coded parameters in the model code of the Noah land surface model with multiple process options (Noah-MP). We performed a Sobol' global sensitivity analysis of Noah-MP for a specific set of process options, which includes 42 out of the 71 standard parameters and 75 out of the 139 hard-coded parameters. The sensitivities of the hydrologic output fluxes latent heat and total runoff as well as their component fluxes were evaluated at 12 catchments within the United States with very different hydrometeorological regimes. Noah-MP's hydrologic output fluxes are sensitive to two thirds of its applicable standard parameters (i.e., Sobol' indexes above 1%). The most sensitive parameter is, however, a hard-coded value in the formulation of soil surface resistance for direct evaporation, which proved to be oversensitive in other land surface models as well. Surface runoff is sensitive to almost all hard-coded parameters of the snow processes and the meteorological inputs. These parameter sensitivities diminish in total runoff. Assessing these parameters in model calibration would require detailed snow observations or the calculation of hydrologic signatures of the runoff data. Latent heat and total runoff exhibit very similar sensitivities because of their tight coupling via the water balance. A calibration of Noah-MP against either of these fluxes should therefore give comparable results. Moreover, these fluxes are sensitive to both plant and soil parameters. Calibrating, for example, only soil parameters hence limit the ability to derive realistic model parameters. It is thus recommended to include the most sensitive hard-coded model parameters that were exposed in this study when calibrating Noah-MP.

  16. Accuracy of clinical neurological examination in diagnosing lumbo-sacral radiculopathy: a systematic literature review.

    PubMed

    Tawa, Nassib; Rhoda, Anthea; Diener, Ina

    2017-02-23

    Lumbar radiculopathy remains a clinical challenge among primary care clinicians in both assessment and diagnosis. This often leads to misdiagnosis and inappropriate treatment of patients resulting in poor health outcomes, exacerbating this already debilitating condition. This review evaluated 12 primary diagnostic accuracy studies that specifically assessed the performance of various individual and grouped clinical neurological tests in detecting nerve root impingement, as established in the current literature. Eight electronic data bases were searched for relevant articles from inception until July 2016. All primary diagnostic studies which investigated the accuracy of clinical neurological test (s) in diagnosing lumbar radiculopathy among patients with low back and referred leg symptoms were screened for inclusion. Qualifying studies were retrieved and independently assessed for methodological quality using the 'Quality Assessment of Diagnostic tests Accuracy Studies' criteria. A total of 12 studies which investigated standard components of clinical neurological examination of (sensory, motor, tendon reflex and neuro-dynamics) of the lumbo-sacral spine were included. The mean inter-observer agreement on quality assessment by two independent reviewers was fair (k = 0.3 - 0.7). The diagnostic performance of sensory testing using MR imaging as a reference standard demonstrated a sensitivity (confidence interval 95%) 0.61 (0.47-0.73) and a specificity of 0.63 (0.38-0.84). Motor tests sensitivity was poor to moderate, ranging from 0.13 (0.04-0.31) to 0.61 (0.36-0.83). Generally, the diagnostic performance of reflex testing was notably good with specificity ranging from (confidence interval 95%) 0.60 (0.51-0.69) to 0.93 (0.87-0.97) and sensitivity ranging from 0.14 (0.09-0.21) to 0.67 (0.21-0.94). Femoral nerve stretch test had a high sensitivity of (confidence interval 95%) 1.00 (0.40-1.00) and specificity of 0.83 (0.52-0.98) while SLR test recorded a mean sensitivity of 0.84 (0.72-0.92) and specificity of 0.78 (0.67-0.87). There is a scarcity of studies on the diagnostic accuracy of clinical neurological examination testing. Furthermore there seem to be a disconnect among researchers regarding the diagnostic utility of lower limb neuro-dynamic tests which include the Straight Leg Raise and Femoral Nerve tests for sciatic and femoral nerve respectively. Whether these tests are able to detect the presence of disc herniation and subsequent nerve root compression or hyper-sensitivity of the sacral and femoral plexus due to mechanical irritation still remains debatable.

  17. Automated analysis of retinal images for detection of referable diabetic retinopathy.

    PubMed

    Abràmoff, Michael D; Folk, James C; Han, Dennis P; Walker, Jonathan D; Williams, David F; Russell, Stephen R; Massin, Pascale; Cochener, Beatrice; Gain, Philippe; Tang, Li; Lamard, Mathieu; Moga, Daniela C; Quellec, Gwénolé; Niemeijer, Meindert

    2013-03-01

    The diagnostic accuracy of computer detection programs has been reported to be comparable to that of specialists and expert readers, but no computer detection programs have been validated in an independent cohort using an internationally recognized diabetic retinopathy (DR) standard. To determine the sensitivity and specificity of the Iowa Detection Program (IDP) to detect referable diabetic retinopathy (RDR). In primary care DR clinics in France, from January 1, 2005, through December 31, 2010, patients were photographed consecutively, and retinal color images were graded for retinopathy severity according to the International Clinical Diabetic Retinopathy scale and macular edema by 3 masked independent retinal specialists and regraded with adjudication until consensus. The IDP analyzed the same images at a predetermined and fixed set point. We defined RDR as more than mild nonproliferative retinopathy and/or macular edema. A total of 874 people with diabetes at risk for DR. Sensitivity and specificity of the IDP to detect RDR, area under the receiver operating characteristic curve, sensitivity and specificity of the retinal specialists' readings, and mean interobserver difference (κ). The RDR prevalence was 21.7% (95% CI, 19.0%-24.5%). The IDP sensitivity was 96.8% (95% CI, 94.4%-99.3%) and specificity was 59.4% (95% CI, 55.7%-63.0%), corresponding to 6 of 874 false-negative results (none met treatment criteria). The area under the receiver operating characteristic curve was 0.937 (95% CI, 0.916-0.959). Before adjudication and consensus, the sensitivity/specificity of the retinal specialists were 0.80/0.98, 0.71/1.00, and 0.91/0.95, and the mean intergrader κ was 0.822. The IDP has high sensitivity and specificity to detect RDR. Computer analysis of retinal photographs for DR and automated detection of RDR can be implemented safely into the DR screening pipeline, potentially improving access to screening and health care productivity and reducing visual loss through early treatment.

  18. Sensitivity, specificity and predictive values of anterior chamber tap in cases of bacterial endophthalmitis.

    PubMed

    Sjoholm-Gomez de Liano, Carl; Soberon-Ventura, Vidal F; Salcedo-Villanueva, Guillermo; Santos-Palacios, Abril; Guerrero-Naranjo, Jose Luis; Fromow-Guerra, Jans; García-Aguirre, Gerardo; Morales-Canton, Virgilio; Velez-Montoya, Raul

    2017-01-01

    To assess the sensitivity, specificity, positive predictive value and negative predictive value of anterior chamber tap for the diagnosis of bacterial endophthalmitis on a population with high prevalence. Retrospective, single centre, case series study. We reviewed all medical records with clinical diagnosis of bacterial endophthalmitis in our hospital from January 1st, 2000 to December 31st 2014. From each record, we documented general demographic data, best corrected visual acuity and vitreous and aqueous tap microbiological results. All cases were further divided according to the endophthalmitis aetiology to perform individual calculations of sensitivity, specificity, positive predictive value, negative predictive value, accuracy and prevalence. We used the results of the vitreous tap as the gold standard for diagnosis of bacterial endophthalmitis. We excluded those records in which the aqueous and vitreous samples were not taken simultaneously or had an incomplete microbiological report. Significance were assessed with chi squared statistics, with an alpha value of 0.05 for statistical significance. A total of 190 cases fulfilled the inclusion/exclusion criteria. Positive culture rate from vitreous samples was 64.74%. Positive culture rate from aqueous sample was 32.11%. Bacteria isolated from aqueous samples matched those isolated from vitreous samples 78.68% of the time. The overall sensitivity was 38.21%, specificity: 75.51%, positive predictive value: 79.66%, negative predictive value: 32.74% ( p  = 0.08). Subgroup analysis showed that anterior chamber taps in cases of post-surgical endophthalmitis had a moderate to low sensitivity (37.73%), high specificity (93%) and high positive predictive value (95%) ( p  < 0.04). The sensitivity and specificity of anterior chamber tap are low and should not be used for critical therapeutic decisions in patients with suspected bacterial endophthalmitis. In cases of post-surgical endophthalmitis, the result of an anterior chamber tap could be used for therapeutic guidance, but only in conjunction with clinical presentation and in the absence of a better method for diagnosis.

  19. Sensitivity and specificity of antibodies against HPV16 E6 and other early proteins for the detection of HPV16-driven oropharyngeal squamous cell carcinoma.

    PubMed

    Holzinger, Dana; Wichmann, Gunnar; Baboci, Lorena; Michel, Angelika; Höfler, Daniela; Wiesenfarth, Manuel; Schroeder, Lea; Boscolo-Rizzo, Paolo; Herold-Mende, Christel; Dyckhoff, Gerhard; Boehm, Andreas; Del Mistro, Annarosa; Bosch, Franz X; Dietz, Andreas; Pawlita, Michael; Waterboer, Tim

    2017-06-15

    To determine the sensitivity and specificity of HPV16 serology as diagnostic marker for HPV16-driven oropharyngeal squamous cell carcinoma (OPSCC), 214 HNSCC patients from Germany and Italy with fresh-frozen tumor tissues and sera collected before treatment were included in this study. Hundred and twenty cancer cases were from the oropharynx and 94 were from head and neck cancer regions outside the oropharynx (45 oral cavity, 12 hypopharynx and 35 larynx). Serum antibodies to early (E1, E2, E6 and E7) and late (L1) HPV16 proteins were analyzed by multiplex serology and were compared to tumor HPV RNA status as the gold standard. A tumor was defined as HPV-driven in the presence of HPV16 DNA and HPV16 transformation-specific RNA transcript patterns (E6*I, E1 ∧ E4 and E1C). Of 120 OPSCC, 66 (55%) were HPV16-driven. HPV16 E6 seropositivity was the best predictor of HPV16-driven OPSCC (diagnostic accuracy 97% [95%CI 92-99%], Cohen's kappa 0.93 [95%CI 0.8-1.0]). Of the 66 HPV-driven OPSCC, 63 were HPV16 E6 seropositive, compared to only one (1.8%) among the 54 non-HPV-driven OPSCC, resulting in a sensitivity of 96% (95%CI 88-98) and a specificity of 98% (95%CI 90-100). Of 94 HNSCC outside the oropharynx, six (6%) were HPV16-driven. In these patients, HPV16 E6 seropositivity had lower sensitivity (50%, 95%CI 19-81), but was highly specific (100%, 95%CI 96-100). In conclusion, HPV16 E6 seropositivity appears to be a highly reliable diagnostic marker for HPV16-driven OPSCC with very high sensitivity and specificity, but might be less sensitive for HPV16-driven HNSCC outside the oropharynx. © 2017 UICC.

  20. Nanotechnology: a promising method for oral cancer detection and diagnosis.

    PubMed

    Chen, Xiao-Jie; Zhang, Xue-Qiong; Liu, Qi; Zhang, Jing; Zhou, Gang

    2018-06-11

    Oral cancer is a common and aggressive cancer with high morbidity, mortality, and recurrence rate globally. Early detection is of utmost importance for cancer prevention and disease management. Currently, tissue biopsy remains the gold standard for oral cancer diagnosis, but it is invasive, which may cause patient discomfort. The application of traditional noninvasive methods-such as vital staining, exfoliative cytology, and molecular imaging-is limited by insufficient sensitivity and specificity. Thus, there is an urgent need for exploring noninvasive, highly sensitive, and specific diagnostic techniques. Nano detection systems are known as new emerging noninvasive strategies that bring the detection sensitivity of biomarkers to nano-scale. Moreover, compared to current imaging contrast agents, nanoparticles are more biocompatible, easier to synthesize, and able to target specific surface molecules. Nanoparticles generate localized surface plasmon resonances at near-infrared wavelengths, providing higher image contrast and resolution. Therefore, using nano-based techniques can help clinicians to detect and better monitor diseases during different phases of oral malignancy. Here, we review the progress of nanotechnology-based methods in oral cancer detection and diagnosis.

  1. Development of an Indirect ELISA for Serological Diagnosis of Bovine herpesvirus 5

    PubMed Central

    Campos, Fabrício S.; da Rosa, Matheus C.; Finger, Paula F.; de Oliveira, Patricia D.; Conceição, Fabricio R.; Fischer, Geferson; Roehe, Paulo M.; Leite, Fábio P. L.

    2016-01-01

    Bovine herpesviruses 1 and 5 (BoHV-1 and BoHV-5) are economically important pathogens, associated with a variety of clinical syndromes, including respiratory and genital disease, reproductive failure and meningoencephalitis. The standard serological assay to diagnose BoHV-1 and BoHV-5 infections is the virus neutralization test (VNT), a time consuming procedure that requires manipulation of infectious virus. In the present study a highly sensitive and specific single dilution indirect ELISA was developed using recombinant glycoprotein D from BoHV-5 as antigen (rgD5ELISA). Bovine serum samples (n = 450) were screened by VNT against BoHV-5a and by rgD5ELISA. Compared with the VNT, the rgD5ELISA demonstrated accuracy of 99.8%, with 100% sensitivity, 96.7% specificity and coefficient of agreement between the tests of 0.954. The rgD5ELISA described here shows excellent agreement with the VNT and is shown to be a simple, convenient, specific and highly sensitive virus-free assay for detection of serum antibodies to BoHV-5. PMID:26866923

  2. Challenges in congenital syphilis surveillance: how are congenital syphilis investigations classified?

    PubMed

    Introcaso, Camille E; Gruber, DeAnn; Bradley, Heather; Peterman, Thomas A; Ewell, Joy; Wendell, Debbie; Foxhood, Joseph; Su, John R; Weinstock, Hillard S; Markowitz, Lauri E

    2013-09-01

    Congenital syphilis is a serious, preventable, and nationally notifiable disease. Despite the existence of a surveillance case definition, congenital syphilis is sometimes classified differently using an algorithm on the Centers for Disease Control and Prevention's case reporting form. We reviewed Louisiana's congenital syphilis electronic reporting system for investigations of infants born from January 2010 to October 2011, abstracted data required for classification, and applied the surveillance definition and the algorithm. We calculated the sensitivities and specificities of the algorithm and Louisiana's classification using the surveillance definition as the surveillance gold standard. Among 349 congenital syphilis investigations, the surveillance definition identified 62 cases. The algorithm had a sensitivity of 91.9% and a specificity of 64.1%. Louisiana's classification had a sensitivity of 50% and a specificity of 91.3% compared with the surveillance definition. The differences between the algorithm and the surveillance definition led to misclassification of congenital syphilis cases. The algorithm should match the surveillance definition. Other state and local health departments should assure that their reported cases meet the surveillance definition.

  3. Specific coil design for SENSE: a six-element cardiac array.

    PubMed

    Weiger, M; Pruessmann, K P; Leussler, C; Röschmann, P; Boesiger, P

    2001-03-01

    In sensitivity encoding (SENSE), the effects of inhomogeneous spatial sensitivity of surface coils are utilized for signal localization in addition to common Fourier encoding using magnetic field gradients. Unlike standard Fourier MRI, SENSE images exhibit an inhomogeneous noise distribution, which crucially depends on the geometrical sensitivity relations of the coils used. Thus, for optimum signal-to-noise-ratio (SNR) and noise homogeneity, specialized coil configurations are called for. In this article we study the implications of SENSE imaging for coil layout by means of simulations and imaging experiments in a phantom and in vivo. New, specific design principles are identified. For SENSE imaging, the elements of a coil array should be smaller than for common phased-array imaging. Furthermore, adjacent coil elements should not overlap. Based on the findings of initial investigations, a configuration of six coils was designed and built specifically for cardiac applications. The in vivo evaluation of this array showed a considerable SNR increase in SENSE images, as compared with a conventional array. Magn Reson Med 45:495-504, 2001. Copyright 2001 Wiley-Liss, Inc.

  4. [Efficacy of a rapid test to diagnose Plasmodium vivax in symptomatic patients of Chiapas, Mexico].

    PubMed

    González-Cerón, Lilia; Rodríguez, Mario H; Betanzos, Angel F; Abadía, Acatl

    2005-01-01

    To evaluate, under laboratory conditions, the sensitivity and specificity of a rapid diagnostic test (OptiMAL), based on immunoreactive strips, to detect Plasmodium vivax infection in febrile patients in Southern Chiapas, Mexico. The presence of parasites in blood samples of 893 patients was investigated by Giemsa-stained thick blood smear microscopic examination (gold standard). A blood drop from the same sample was smeared on immunoreactive strips to investigate the presence of the parasite pLDH. Discordant results were resolved by PCR amplification of the parasite's 18S SSU rRNA, to discard infection. OptiMAL had an overall sensitivity of 93.3% and its specificity was 99.5%. Its positive and negative predictive values were 96.5% and 98.9%, respectively. Signal intensity in OptiMAL strips correlated well with the parasitemia density in the blood samples (r = 0.601, p = 0.0001). This rapid test had acceptable sensitivity and specificity to detect P. vivax under laboratory conditions and could be useful for malaria diagnosis in field operations in Mexico.

  5. Evaluation of Aspergillus PCR protocols for testing serum specimens.

    PubMed

    White, P Lewis; Mengoli, Carlo; Bretagne, Stéphane; Cuenca-Estrella, Manuel; Finnstrom, Niklas; Klingspor, Lena; Melchers, Willem J G; McCulloch, Elaine; Barnes, Rosemary A; Donnelly, J Peter; Loeffler, Juergen

    2011-11-01

    A panel of human serum samples spiked with various amounts of Aspergillus fumigatus genomic DNA was distributed to 23 centers within the European Aspergillus PCR Initiative to determine analytical performance of PCR. Information regarding specific methodological components and PCR performance was requested. The information provided was made anonymous, and meta-regression analysis was performed to determine any procedural factors that significantly altered PCR performance. Ninety-seven percent of protocols were able to detect a threshold of 10 genomes/ml on at least one occasion, with 83% of protocols reproducibly detecting this concentration. Sensitivity and specificity were 86.1% and 93.6%, respectively. Positive associations between sensitivity and the use of larger sample volumes, an internal control PCR, and PCR targeting the internal transcribed spacer (ITS) region were shown. Negative associations between sensitivity and the use of larger elution volumes (≥100 μl) and PCR targeting the mitochondrial genes were demonstrated. Most Aspergillus PCR protocols used to test serum generate satisfactory analytical performance. Testing serum requires less standardization, and the specific recommendations shown in this article will only improve performance.

  6. Evaluation of Aspergillus PCR Protocols for Testing Serum Specimens▿†

    PubMed Central

    White, P. Lewis; Mengoli, Carlo; Bretagne, Stéphane; Cuenca-Estrella, Manuel; Finnstrom, Niklas; Klingspor, Lena; Melchers, Willem J. G.; McCulloch, Elaine; Barnes, Rosemary A.; Donnelly, J. Peter; Loeffler, Juergen

    2011-01-01

    A panel of human serum samples spiked with various amounts of Aspergillus fumigatus genomic DNA was distributed to 23 centers within the European Aspergillus PCR Initiative to determine analytical performance of PCR. Information regarding specific methodological components and PCR performance was requested. The information provided was made anonymous, and meta-regression analysis was performed to determine any procedural factors that significantly altered PCR performance. Ninety-seven percent of protocols were able to detect a threshold of 10 genomes/ml on at least one occasion, with 83% of protocols reproducibly detecting this concentration. Sensitivity and specificity were 86.1% and 93.6%, respectively. Positive associations between sensitivity and the use of larger sample volumes, an internal control PCR, and PCR targeting the internal transcribed spacer (ITS) region were shown. Negative associations between sensitivity and the use of larger elution volumes (≥100 μl) and PCR targeting the mitochondrial genes were demonstrated. Most Aspergillus PCR protocols used to test serum generate satisfactory analytical performance. Testing serum requires less standardization, and the specific recommendations shown in this article will only improve performance. PMID:21940479

  7. Accuracy of Two Malaria Rapid Diagnostic Tests (RDTS) for Initial Diagnosis and Treatment Monitoring in a High Transmission Setting in Uganda

    PubMed Central

    Mbabazi, Phoebe; Hopkins, Heidi; Osilo, Emmanuel; Kalungu, Michael; Byakika-Kibwika, Pauline; Kamya, Moses R.

    2015-01-01

    Malaria rapid diagnostic tests (RDTs) may improve fever management in areas without microscopy. We compared the accuracy of histidine-rich protein 2 (HRP2) and Plasmodium lactate dehydrogenase (pLDH)-based RDTs, using expert microscopy as a gold standard, for initial diagnosis, treatment monitoring, and diagnosis of recurrent malaria in a cohort of children followed longitudinally in a high-transmission area in Uganda. For 305 initial fever episodes, sensitivity was 98% for HRP2 and 87% for pLDH, whereas specificity was 55% and 96%, respectively. The HRP2 gave 51% false-positive results on Day 28, whereas pLDH gave no false positives after Day 7. For 59 recurrent fever episodes during follow-up, sensitivity was 100% for HRP2 and 91% for pLDH, whereas specificity was 33% and 100%, respectively. The HRP2-based RDTs are useful for initial diagnosis of malaria caused by superior sensitivity; however, as a result of superior specificity, pLDH-based RDTs are more appropriate to monitor treatment and diagnose recurrent malaria. PMID:25624399

  8. Diagnostic performance of serological tests to detect antibodies against acute scrub typhus infection in central India.

    PubMed

    Pote, Kiran; Narang, Rahul; Deshmukh, Pradeep

    2018-01-01

    Differentiating scrub typhus from other acute febrile illness is difficult due to non specificity of clinical symptoms and relative absence of eschar in Indian population. The diagnosis thus relies mainly on laboratory tests. Antibody based serological tests are mainstay of scrub typhus diagnosis. Here, we evaluated the diagnostic performance of IgM ELISA, IgM IFA and ICT to detect antibodies against O. tsutsugamushi in acute serum of febrile patients. The serum samples from 600 randomly selected patients suffering from acute undifferentiated fever were tested by all the three tests mentioned above. We used latent class analysis to generate unbiased results as all the tests for scrub typhus diagnosis are imperfect and none of them can be considered as reference standard. We found that IgM ELISA with cutoff titer 0.5 OD has high diagnostic accuracy (sensitivity 99.9% and specificity 99.15) than IgM IFA (sensitivity 96.8% and specificity 99.7%) for scrub typhus diagnosis. ICT used in our study had very high specificity 100% but low sensitivity (38%) which would limit its use for acute serum samples. ICT being a screening or point of care test, has to be more sensitive while some compromise with specificity is affordable. Hence, optimal cutoff for ICT should be evaluated under different settings. IgM ELISA being simple and affordable could be an alternative diagnostic test to IgM IFA which is subjective and costly.

  9. Utility of dengue NS1 antigen rapid diagnostic test for use in difficult to reach areas and its comparison with dengue NS1 ELISA and qRT-PCR.

    PubMed

    Shukla, Mohan K; Singh, Neeru; Sharma, Ravendra K; Barde, Pradip V

    2017-07-01

    The objective of this study was to demonstrate the utility of dengue virus (DENV) non structural protein 1 (NS1) based rapid diagnostic test (RDT) for use in tribal and difficult to reach areas for early dengue (DEN) diagnosis in acute phase patients and evaluate its sensitivity and specificity against DENV NS1 enzyme linked immune sorbent assay (ELISA) and real time reverse transcriptase polymerase chain reaction (qRT-PCR). The DENV NS1 RDT was used for preliminary diagnosis during outbreaks in difficult to reach rural and tribal areas. The diagnosis was confirmed by DENV NS1 ELISA in the laboratory. The samples were also tested and serotyped by qRT-PCR. The results were evaluated using statistical tests. The DENV NS1 RDT showed 99.2% sensitivity and 96.0% specificity when analyzed using DENV NS1 ELISA as standard. The specificity and sensitivity of the RDT when compared with qRT-PCR was 93.6% and 91.1%, respectively. The serotype specific evaluation showed more than 90% sensitivity and specificity for DENV-1, 2, and 3. The RDT proved a good diagnostic tool in difficult to reach rural and tribal areas. Further evaluation studies with different commercially available RDTs in different field conditions are essential, that will help clinicians and patients for treatment and programme managers for timely intervention. © 2017 Wiley Periodicals, Inc.

  10. External Quality Assessment for Zika Virus Molecular Diagnostic Testing, Brazil.

    PubMed

    Fischer, Carlo; Pedroso, Celia; Mendrone, Alfredo; Bispo de Filippis, Ana Maria; Vallinoto, Antonio Carlos Rosário; Ribeiro, Bergmann Morais; Durigon, Edison Luiz; Marques, Ernesto T A; Campos, Gubio S; Viana, Isabelle F T; Levi, José Eduardo; Scarpelli, Luciano Cesar; Nogueira, Mauricio Lacerda; Bastos, Michele de Souza; Souza, Nathalia C Santiago; Khouri, Ricardo; Lira, Sanny; Komninakis, Shirley Vasconcelos; Baronti, Cécile; Charrel, Rémi N; Kümmerer, Beate M; Drosten, Christian; Brites, Carlos; de Lamballerie, Xavier; Niedrig, Matthias; Netto, Eduardo Martins; Drexler, Jan Felix

    2018-05-01

    We conducted an external quality assessment of Zika virus molecular diagnostic tests in Brazil using a new Zika virus standard. Of 15 laboratories, 73% showed limited sensitivity and specificity. Viral load estimates varied significantly. Continuous quality assurance is needed to adequately estimate risk for Zika virus-associated disease and determine patient care.

  11. Diagnosis of Autism Spectrum Disorders in 2-Year-Olds: A Study of Community Practice

    ERIC Educational Resources Information Center

    Corsello, Christina M.; Akshoomoff, Natacha; Stahmer, Aubyn C.

    2013-01-01

    Background: Longitudinal research studies have demonstrated that experienced clinicians using standardized assessment measures can make a reliable diagnosis of autism spectrum disorders (ASDs) in children under age 3. Limited data are available regarding the sensitivity and specificity of these measures in community settings. The aims of this…

  12. Comparison of fecal DNA extraction kits for the detection of Mycobacterium avium subsp. paratuberculosis by polymerase chain reaction

    USDA-ARS?s Scientific Manuscript database

    Culture of Mycobacterium avium subsp. paratuberculosis (MAP) from feces has been considered the gold standard for the diagnosis of paratuberculosis for many years. However, direct fecal PCR is becoming more widely used today, demonstrating similar sensitivity and specificity to culture. To ensure ef...

  13. A Laboratory Exercise Illustrating the Sensitivity and Specificity of Western Blot Analysis

    ERIC Educational Resources Information Center

    Chang, Ming-Mei; Lovett, Janice

    2011-01-01

    Western blot analysis, commonly known as "Western blotting," is a standard tool in every laboratory where proteins are analyzed. It involves the separation of polypeptides in polyacrylamide gels followed by the electrophoretic transfer of the separated polypeptides onto a nitrocellulose or polyvinylidene fluoride membrane. A replica of the…

  14. Role of Inflammation and Insulin Resistance in Mouse Models of Breast Cancer

    DTIC Science & Technology

    2012-04-01

    understood. We have found that the anti-inflammatory and insulin sensitizing effects of omega-3 fatty acids (ω3 FAs) are mediated by a specific G...the test group receive standard diet supplemented with ω3 FA (EPA and DHA ) while preserving total calories from fat. BODY: Task 1: Treating mice

  15. Detection of progressive idiopathic scoliosis during growth using back surface topography: a prospective study of 100 patients.

    PubMed

    De Korvin, G; Randriaminahisoa, T; Cugy, E; Cheze, L; de Sèze, M

    2014-12-01

    The progression of adolescent idiopathic scoliosis is typically monitored via regular radiographic follow-up. The Cobb angle (as measured on whole-spine radiographs) is considered as the gold standard in scoliosis monitoring. To determine the sensitivity and specificity of back surface topography parameters, with a view to detecting changes in the Cobb angle. One hundred patients (mean age: 13.3) with Cobb angles greater than 10 degrees were included. Topographic parameters were measured in a standard position and in a position with hunched shoulders. Gibbosities and spinal curvatures were evaluated. An increase of more than 2 degrees in any one gibbosity or in the sum of the gibbosities (in either of the two examination positions) enabled the detection of a five-degree increase in the Cobb angle with a sensitivity of 86% and a specificity of 50%. If the present results are confirmed by other studies, analysis with back surface topography parameters may reduce the number of X-ray examinations required to detect increases in the Cobb angle. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  16. NMP22 BladderChek Test: point-of-care technology with life- and money-saving potential.

    PubMed

    Tomera, Kevin M

    2004-11-01

    A new, relatively obscure tumor marker assay, the NMP22 BladderChek Test (Matritech, Inc.), represents a paradigm shift in the diagnosis and management of urinary bladder cancer (transitional cell carcinoma). Specifically, BladderChek should be employed every time a cystoscopy is performed, with corresponding changes in the diagnostic protocol and the guidelines of the American Urological Association for the diagnosis and management of bladder cancer. Currently, cystoscopy is the reference standard and NMP22 BladderChek Test in combination with cystoscopy improves the performance of cystoscopy. At every stage of disease, BladderChek provides a higher sensitivity for the detection of bladder cancer than cytology, which now represents the adjunctive standard of care. Moreover, BladderChek is four-times more sensitive than cytology and is available at half the cost. Early detection of bladder cancer improves prognosis, quality of life and survival. BladderChek may be analogous to the prostate-specific antigen test and eventually expand beyond the urologic setting into the primary care setting for the testing of high-risk patients characterized by smoking history, occupational exposures or age.

  17. Development of SYBR Green I Based Real-Time RT-PCR Assay for Specific Detection of Watermelon silver mottle Virus.

    PubMed

    Rao, Xueqin; Sun, Jie

    2015-09-01

    Watermelon silver mottle virus (WSMoV), which belongs to the genus Tospovirus , causes significant loss in Cucurbitaceae plants. Development of a highly sensitive and reliable detection method for WSMoV. Recombinant plasmids for targeting the sequence of nucleocapsid protein gene of WSMoV were constructed. SYBR Green I real-time PCR was established and evaluated with standard recombinant plasmids and 27 watermelon samples showing WSMoV infection symptoms. The recombinant plasmid was used as template for SYBR Green I real-time PCR to generate standard and melting curves. Melting curve analysis indicated no primer-dimers and non-specific products in the assay. No cross-reaction was observed with Capsicum chlorosis virus (genus Tospovirus ) and Cucumber mosaic virus (genus Cucumovirus). Repeatability tests indicated that inter-assay variability of the Ct values was 1.6%. A highly sensitive, reliable and rapid detection method of SYBR Green I real-time PCR for timely detection of WSMoV plants and vector thrips was established, which will facilitate disease forecast and control.

  18. In vivo real-time cavitation imaging in moving organs

    NASA Astrophysics Data System (ADS)

    Arnal, B.; Baranger, J.; Demene, C.; Tanter, M.; Pernot, M.

    2017-02-01

    The stochastic nature of cavitation implies visualization of the cavitation cloud in real-time and in a discriminative manner for the safe use of focused ultrasound therapy. This visualization is sometimes possible with standard echography, but it strongly depends on the quality of the scanner, and is hindered by difficulty in discriminating from highly reflecting tissue signals in different organs. A specific approach would then permit clear validation of the cavitation position and activity. Detecting signals from a specific source with high sensitivity is a major problem in ultrasound imaging. Based on plane or diverging wave sonications, ultrafast ultrasonic imaging dramatically increases temporal resolution, and the larger amount of acquired data permits increased sensitivity in Doppler imaging. Here, we investigate a spatiotemporal singular value decomposition of ultrafast radiofrequency data to discriminate bubble clouds from tissue based on their different spatiotemporal motion and echogenicity during histotripsy. We introduce an automation to determine the parameters of this filtering. This method clearly outperforms standard temporal filtering techniques with a bubble to tissue contrast of at least 20 dB in vitro in a moving phantom and in vivo in porcine liver.

  19. [Validity of anthropometric measurements and weight perceptions reported by relatives of children under 4 years old].

    PubMed

    Patiño-Villena, Begoña; Chirlaque, María Dolores; Salmerón, Diego; González, Eduardo; Navarro, Carmen

    2016-01-01

    To assess the validity of weight and height measurements reported by parents and the perception of their children's weight status in order to assess the prevalence of overweight children under 4 years old. Cross-sectional study. Anthropometric data was collected by self-report questionnaires completed by parents of children 3-45 months old: 1) information from paediatric check-ups (gold standard); 2) information reported from the home environment; and 3) data from individual perceptions. WHO standards were used. Reported height was underestimated, thus reported weight/height and BMI/age were overestimated. Overweight prevalence according to paediatric check-ups was 18.6%, compared to 26.5% reported prevalence, showing a moderate concordance (Kappa: 0.47 [0.34-0.60]), 70% sensitivity and 84% specificity. Subjective perception was 11.2%, representing 30% sensitivity and 93% specificity. The reported information has little validity for population-based studies, as height is underestimated and overweight status is not correctly perceived due to distortion of individual perception. Questionnaires must be validated and awareness raised among families. Copyright © 2016 SESPAS. Published by Elsevier Espana. All rights reserved.

  20. Ultrasonography for endoleak detection after endoluminal abdominal aortic aneurysm repair.

    PubMed

    Abraha, Iosief; Luchetta, Maria Laura; De Florio, Rita; Cozzolino, Francesco; Casazza, Giovanni; Duca, Piergiorgio; Parente, Basso; Orso, Massimiliano; Germani, Antonella; Eusebi, Paolo; Montedori, Alessandro

    2017-06-09

    People with abdominal aortic aneurysm who receive endovascular aneurysm repair (EVAR) need lifetime surveillance to detect potential endoleaks. Endoleak is defined as persistent blood flow within the aneurysm sac following EVAR. Computed tomography (CT) angiography is considered the reference standard for endoleak surveillance. Colour duplex ultrasound (CDUS) and contrast-enhanced CDUS (CE-CDUS) are less invasive but considered less accurate than CT. To determine the diagnostic accuracy of colour duplex ultrasound (CDUS) and contrast-enhanced-colour duplex ultrasound (CE-CDUS) in terms of sensitivity and specificity for endoleak detection after endoluminal abdominal aortic aneurysm repair (EVAR). We searched MEDLINE, Embase, LILACS, ISI Conference Proceedings, Zetoc, and trial registries in June 2016 without language restrictions and without use of filters to maximize sensitivity. Any cross-sectional diagnostic study evaluating participants who received EVAR by both ultrasound (with or without contrast) and CT scan assessed at regular intervals. Two pairs of review authors independently extracted data and assessed quality of included studies using the QUADAS 1 tool. A third review author resolved discrepancies. The unit of analysis was number of participants for the primary analysis and number of scans performed for the secondary analysis. We carried out a meta-analysis to estimate sensitivity and specificity of CDUS or CE-CDUS using a bivariate model. We analysed each index test separately. As potential sources of heterogeneity, we explored year of publication, characteristics of included participants (age and gender), direction of the study (retrospective, prospective), country of origin, number of CDUS operators, and ultrasound manufacturer. We identified 42 primary studies with 4220 participants. Twenty studies provided accuracy data based on the number of individual participants (seven of which provided data with and without the use of contrast). Sixteen of these studies evaluated the accuracy of CDUS. These studies were generally of moderate to low quality: only three studies fulfilled all the QUADAS items; in six (40%) of the studies, the delay between the tests was unclear or longer than four weeks; in eight (50%), the blinding of either the index test or the reference standard was not clearly reported or was not performed; and in two studies (12%), the interpretation of the reference standard was not clearly reported. Eleven studies evaluated the accuracy of CE-CDUS. These studies were of better quality than the CDUS studies: five (45%) studies fulfilled all the QUADAS items; four (36%) did not report clearly the blinding interpretation of the reference standard; and two (18%) did not clearly report the delay between the two tests.Based on the bivariate model, the summary estimates for CDUS were 0.82 (95% confidence interval (CI) 0.66 to 0.91) for sensitivity and 0.93 (95% CI 0.87 to 0.96) for specificity whereas for CE-CDUS the estimates were 0.94 (95% CI 0.85 to 0.98) for sensitivity and 0.95 (95% CI 0.90 to 0.98) for specificity. Regression analysis showed that CE-CDUS was superior to CDUS in terms of sensitivity (LR Chi 2 = 5.08, 1 degree of freedom (df); P = 0.0242 for model improvement).Seven studies provided estimates before and after administration of contrast. Sensitivity before contrast was 0.67 (95% CI 0.47 to 0.83) and after contrast was 0.97 (95% CI 0.92 to 0.99). The improvement in sensitivity with of contrast use was statistically significant (LR Chi 2 = 13.47, 1 df; P = 0.0002 for model improvement).Regression testing showed evidence of statistically significant effect bias related to year of publication and study quality within individual participants based CDUS studies. Sensitivity estimates were higher in the studies published before 2006 than the estimates obtained from studies published in 2006 or later (P < 0.001); and studies judged as low/unclear quality provided higher estimates in sensitivity. When regression testing was applied to the individual based CE-CDUS studies, none of the items, namely direction of the study design, quality, and age, were identified as a source of heterogeneity.Twenty-two studies provided accuracy data based on number of scans performed (of which four provided data with and without the use of contrast). Analysis of the studies that provided scan based data showed similar results. Summary estimates for CDUS (18 studies) showed 0.72 (95% CI 0.55 to 0.85) for sensitivity and 0.95 (95% CI 0.90 to 0.96) for specificity whereas summary estimates for CE-CDUS (eight studies) were 0.91 (95% CI 0.68 to 0.98) for sensitivity and 0.89 (95% CI 0.71 to 0.96) for specificity. This review demonstrates that both ultrasound modalities (with or without contrast) showed high specificity. For ruling in endoleaks, CE-CDUS appears superior to CDUS. In an endoleak surveillance programme CE-CDUS can be introduced as a routine diagnostic modality followed by CT scan only when the ultrasound is positive to establish the type of endoleak and the subsequent therapeutic management.

Top