Carbonate and silicate rock standards for cosmogenic 36Cl
NASA Astrophysics Data System (ADS)
Mechernich, Silke; Dunai, Tibor J.; Binnie, Steven A.; Goral, Tomasz; Heinze, Stefan; Dewald, Alfred; Benedetti, Lucilla; Schimmelpfennig, Irene; Phillips, Fred; Marrero, Shasta; Akif Sarıkaya, Mehmet; Gregory, Laura C.; Phillips, Richard J.; Wilcken, Klaus; Simon, Krista; Fink, David
2017-04-01
The number of studies using cosmogenic nuclides has increased multi-fold during the last two decades and several new dedicated target preparation laboratories and Accelerator Mass Spectrometry (AMS) facilities have been established. Each facility uses sample preparation and AMS measurement techniques particular to their needs. It is thus desirable to have community-accepted and well characterized rock standards available for routine processing using identical target preparation procedures and AMS measurement methods as carried out for samples of unknown cosmogenic nuclide concentrations. The usefulness of such natural standards is that they allow more rigorous quality control, for example, the long-term reproducibility of results and hence measurement precision, or the testing of new target preparation techniques or newly established laboratories. This is particularly pertinent for in-situ 36Cl studies due to the multiplicity of 36Cl production pathways that requires a variety of elemental and isotopic determinations in addition to AMS 36Cl assay. We have prepared two natural rock samples (denoted CoCal-N and CoFsp-N) to serve as standard material for in situ-produced cosmogenic 36Cl analysis. The sample CoCal-N is a pure limestone prepared from pebbles in a Namibian lag deposit, while the alkali-feldspar CoFsp-N is derived from a single crystal in a Namibian pegmatite. The sample preparation took place at the University of Cologne, where first any impurities were removed manually from both standards. CoCal-N was leached in 10 % HNO3 to remove the outer rim, and afterwards crushed and sieved to 250-500 μm size fractions. CoFsp-N was crushed, sieved to 250-500 μm size fractions and then leached in 1% HNO3 / 1% HF until 20% of the sample were removed. Both standards were thoroughly mixed using a rotating sample splitter before being distributed to other laboratories. To date, a total of 28 CoCal-N aliquots (between 2 and 16 aliquots per facility) and 31 CoFsp-N aliquots (between 2 and 20 aliquots per facility) have been analyzed by six target preparation laboratories employing five different AMS facilities. Currently, the internal reproducibility of the measurements underlines the homogeneity of both standards. The inter-laboratory comparison suggests low over-dispersion. Further measurements are pending and should allow meaningful statistical analysis. Both standard materials are freely available and can be obtained from Tibor Dunai tdunai@uni-koeln.de).
The method for extracting and preparing a dermal or surface wipe sample for analysis of acidic persistent organic pollutants is summarized in this standard operating procedure. It covers the extraction and concentration of samples that are to be analyzed by gas chromatography/mas...
Standard method of test for grindability of coal by the Hardgrove-machine method
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1975-01-01
A procedure is described for sampling coal, grinding in a Hardgrove grinding machine, and passing through standard sieves to determine the degree of pulverization of coals. The grindability index of the coal tested is calculated from a calibration chart prepared by plotting weight of material passing a No. 200 sieve versus the Hardgrove Grindability Index for the standard reference samples. The Hardgrove machine is shown schematically. The method for preparing and determining grindability indexes of standard reference samples is given in the appendix. (BLM)
Investigating a Drop-on-Demand Microdispenser for Standardized Sample Preparation
2012-09-01
Demand Microdispenser for Standardized Sample Preparation Ellen L. Holthoff, Mikella E. Farrell, and Paul M. Pellegrino Sensors and Electron Devices...instrument. The use of a gravimetric method, such as a quartz crystal microbalance4 ( QCM ) or a sensitive microbalance as discussed in this report, is
Standardized Sample Preparation Using a Drop-on-Demand Printing Platform
2013-05-07
successful and robust methodology for energetic sample preparation. Keywords: drop-on-demand; inkjet printing; sample preparation OPEN ACCESS...on a similar length scale. Recently, drop-on-demand inkjet printing technology has emerged as an effective approach to produce test materials to...which most of the material is concentrated along the edges, samples prepared using drop-on-demand inkjet technology demonstrate excellent uniform
NASA Technical Reports Server (NTRS)
Carden, J. L.; Browner, R.
1982-01-01
The preparation and analysis of standardized waste samples for controlled ecological life support systems (CELSS) are considered. Analysis of samples from wet oxidation experiments, the development of ion chromatographic techniques utilizing conventional high pressure liquid chromatography (HPLC) equipment, and an investigation of techniques for interfacing an ion chromatograph (IC) with an inductively coupled plasma optical emission spectrometer (ICPOES) are discussed.
7 CFR 61.34 - Drawing and preparation of sample.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 3 2010-01-01 2010-01-01 false Drawing and preparation of sample. 61.34 Section 61.34 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards... Cottonseed Samplers § 61.34 Drawing and preparation of sample. Each licensed cottonseed sampler shall draw...
The method for extracting and preparing indoor and outdoor air samples for analysis of polar persistent organic pollutants is summarized in this SOP. It covers the preparation of samples that are to be analyzed by gas chromatography/mass spectrometry.
Szulc, P; Naylor, K; Hoyle, N R; Eastell, R; Leary, E T
2017-09-01
The National Bone Health Alliance (NBHA) recommends standardized sample handling and patient preparation for C-terminal telopeptide of type I collagen (CTX-I) and N-terminal propeptide of type I procollagen (PINP) measurements to reduce pre-analytical variability. Controllable and uncontrollable patient-related factors are reviewed to facilitate interpretation and minimize pre-analytical variability. The IOF and the International Federation of Clinical Chemistry (IFCC) Bone Marker Standards Working Group have identified PINP and CTX-I in blood to be the reference markers of bone turnover for the fracture risk prediction and monitoring of osteoporosis treatment. Although used in clinical research for many years, bone turnover markers (BTM) have not been widely adopted in clinical practice primarily due to their poor within-subject and between-lab reproducibility. The NBHA Bone Turnover Marker Project team aim to reduce pre-analytical variability of CTX-I and PINP measurements through standardized sample handling and patient preparation. Recommendations for sample handling and patient preparations were made based on review of available publications and pragmatic considerations to reduce pre-analytical variability. Controllable and un-controllable patient-related factors were reviewed to facilitate interpretation and sample collection. Samples for CTX-I must be collected consistently in the morning hours in the fasted state. EDTA plasma is preferred for CTX-I for its greater sample stability. Sample collection conditions for PINP are less critical as PINP has minimal circadian variability and is not affected by food intake. Sample stability limits should be observed. The uncontrollable aspects (age, sex, pregnancy, immobility, recent fracture, co-morbidities, anti-osteoporotic drugs, other medications) should be considered in BTM interpretation. Adopting standardized sample handling and patient preparation procedures will significantly reduce controllable pre-analytical variability. The successful adoption of such recommendations necessitates the close collaboration of various stakeholders at the global stage, including the laboratories, the medical community, the reagent manufacturers and the regulatory agencies.
Biomedical graphite and CaF2 preparation and measurement at PRIME Lab
NASA Astrophysics Data System (ADS)
Jackson, George S.; Einstein, Jane A.; Kubley, Tom; Martin, Berdine; Weaver, Connie M.; Caffee, Marc
2015-10-01
The biomedical program at PRIME Lab has prepared radiocarbon and 41Ca as tracers for a variety of applications. Over the last decade several hundred 14C samples and several thousand 41Ca samples have been measured per year. Biomedical samples pose challenges that are relatively rare in the AMS community. We will discuss how to prepare and compensate for samples that have isotope ratios above the dynamic range of AMS, high interference rates, and small samples sizes. In the case of 41Ca, the trade off in the chromatography between yield and sample cleanliness will be analyzed. Secondary standards that have isotope ratios commonly encountered in our applications are routinely prepared. We use material from the Joint Research Centre's Institute for Reference Materials and Measurement: IRMM-3701/4, 3701/5, and 3701/6 and a standard produced by PRIME Lab for 41Ca. We use International Atomic Energy Agency's IAEA C-3, IAEA C-7, IAEA C-8, and a ∼12.5× modern oxalic acid secondary standard supplied by Lawrence Livermore National Laboratory for 14C. We will discuss our precision, reproducibility, and the relative agreement between our measured and the reported values for these materials.
Automated cellular sample preparation using a Centrifuge-on-a-Chip.
Mach, Albert J; Kim, Jae Hyun; Arshi, Armin; Hur, Soojung Claire; Di Carlo, Dino
2011-09-07
The standard centrifuge is a laboratory instrument widely used by biologists and medical technicians for preparing cell samples. Efforts to automate the operations of concentration, cell separation, and solution exchange that a centrifuge performs in a simpler and smaller platform have had limited success. Here, we present a microfluidic chip that replicates the functions of a centrifuge without moving parts or external forces. The device operates using a purely fluid dynamic phenomenon in which cells selectively enter and are maintained in microscale vortices. Continuous and sequential operation allows enrichment of cancer cells from spiked blood samples at the mL min(-1) scale, followed by fluorescent labeling of intra- and extra-cellular antigens on the cells without the need for manual pipetting and washing steps. A versatile centrifuge-analogue may open opportunities in automated, low-cost and high-throughput sample preparation as an alternative to the standard benchtop centrifuge in standardized clinical diagnostics or resource poor settings.
Sample and data processing considerations for the NIST quantitative infrared database
NASA Astrophysics Data System (ADS)
Chu, Pamela M.; Guenther, Franklin R.; Rhoderick, George C.; Lafferty, Walter J.; Phillips, William
1999-02-01
Fourier-transform infrared (FT-IR) spectrometry has become a useful real-time in situ analytical technique for quantitative gas phase measurements. In fact, the U.S. Environmental Protection Agency (EPA) has recently approved open-path FT-IR monitoring for the determination of hazardous air pollutants (HAP) identified in EPA's Clean Air Act of 1990. To support infrared based sensing technologies, the National Institute of Standards and Technology (NIST) is currently developing a standard quantitative spectral database of the HAPs based on gravimetrically prepared standard samples. The procedures developed to ensure the quantitative accuracy of the reference data are discussed, including sample preparation, residual sample contaminants, data processing considerations, and estimates of error.
Standardization of a traditional polyherbo-mineral formulation - Brahmi vati.
Mishra, Amrita; Mishra, Arun K; Ghosh, Ashoke K; Jha, Shivesh
2013-01-01
The present study deals with standardization of an in-house standard preparation and three marketed samples of Brahmi vati, which is a traditional medicine known to be effective in mental disorders, convulsions, weak memory, high fever and hysteria. Preparation and standardization have been done by following modern scientific quality control procedures for raw material and the finished products. The scanning electron microscopic (SEM) analysis showed the reduction of metals and minerals (particle size range 2-5 µm) which indicates the proper preparation of bhasmas, the important ingredient of Brahmi vati. Findings of EDX analysis of all samples of Brahmi vati suggested the absence of Gold, an important constituent of Brahmi vati in two marketed samples. All the samples of Brahmi vati were subjected to quantitative estimation of Bacoside A (marker compound) by HPTLC technique. Extraction of the samples was done in methanol and the chromatograms were developed in Butanol: Glacial acetic acid: water (4.5:0.5:5 v/v) and detected at 225nm. The regression analysis of calibration plots of Bacoside A exhibited linear relationship in the concentration range of 50-300 ng, while the % recovery was found to be 96.06% w/w, thus proving the accuracy and precision of the analysis. The Bacoside A content in the in-house preparation was found to be higher than that of the commercial samples. The proposed HPTLC method was found to be rapid, simple and accurate for quantitative estimation of Bacoside A in different formulations. The results of this study could be used as a model data in the standardization of Brahmi vati.
Standards for electron probe microanalysis of silicates prepared by convenient method
NASA Technical Reports Server (NTRS)
Walter, L. S.
1966-01-01
Standard compositions suitable for electron probe microanalysis of various silicates are prepared by coprecipitation of specified salts with colloidal silica to form a gel which is decomposed into a powdered oxide mixture and compressed into thin pellets. These pellets of predetermined standard are compared with a silicate sample to determine its composition.
The method for extracting and preparing a drinking water sample for analysis of atrazine is summarized in this SOP. It covers the extraction and concentration of samples that are to be analyzed by gas chromatography/ mass spectrometry.
This SOP summarizes the method for extracting and preparing a hard floor surface wipe or food preparation surface wipe sample for analysis of neutral persistent organic. It covers the extraction and concentration of samples that are to be analyzed by gas chromatography/mass spect...
This SOP describes the method for collection of the food preparation surface wipe samples for the measurement of persistent organic pollutants (POP). This method uses a wipe to collect POP residues from a surface where a study participant prepares food the most often (i.e., kitch...
This SOP describes the extraction and preparation of a solid food sample for analysis of acidic persistent organic pollutants such as acid herbicides, pentachlorphenol, and 3,5,6-trichloro-2-phenol. It covers the extraction, concentration and derivatization of samples that are to...
This SOP summarizes the method for extracting and preparing a dust or soil sample for analysis of neutral persistent organic pollutants. It covers the extraction and concentration of samples that are to be analyzed by gas chromatography/mass spectrometry.
The method for extracting and preparing a dermal (hand) wipe sample for analysis of neutral persistent organic pollutants is summarized in this SOP. It covers the extraction and concentration of samples that are to be analyzed by gas chromatography/mass spectrometry.
This SOP describes the extraction and preparation of a liquid food sample for analysis of acidic persistent organic pollutants such as acid herbicides, pentachlorphenol, and 3,5,6-trichloro-2-phenol. It covers the extraction, concentration and derivatization of samples that are t...
The purpose of this SOP is to describe the procedures for extracting and preparing an air sample consisting of a polyurethane foam (PUF) plug and Teflon-coated glass fiber filter (Pallflex T60A20) for analysis of pesticides. This procedure covers sample preparation for samples t...
Jiang, Jian; James, Christopher A; Wong, Philip
2016-09-05
A LC-MS/MS method has been developed and validated for the determination of glycine in human cerebrospinal fluid (CSF). The validated method used artificial cerebrospinal fluid as a surrogate matrix for calibration standards. The calibration curve range for the assay was 100-10,000ng/mL and (13)C2, (15)N-glycine was used as an internal standard (IS). Pre-validation experiments were performed to demonstrate parallelism with surrogate matrix and standard addition methods. The mean endogenous glycine concentration in a pooled human CSF determined on three days by using artificial CSF as a surrogate matrix and the method of standard addition was found to be 748±30.6 and 768±18.1ng/mL, respectively. A percentage difference of -2.6% indicated that artificial CSF could be used as a surrogate calibration matrix for the determination of glycine in human CSF. Quality control (QC) samples, except the lower limit of quantitation (LLOQ) QC and low QC samples, were prepared by spiking glycine into aliquots of pooled human CSF sample. The low QC sample was prepared from a separate pooled human CSF sample containing low endogenous glycine concentrations, while the LLOQ QC sample was prepared in artificial CSF. Standard addition was used extensively to evaluate matrix effects during validation. The validated method was used to determine the endogenous glycine concentrations in human CSF samples. Incurred sample reanalysis demonstrated reproducibility of the method. Copyright © 2016 Elsevier B.V. All rights reserved.
Uranium in NIMROC standard igneous rock samples
NASA Technical Reports Server (NTRS)
Rowe, M. W.; Herndon, J. M.
1976-01-01
Results are reported for analysis of the uranium in multiple samples of each of six igneous-rock standards (dunite, granite, lujavrite, norite, pyroxenite, and syenite) prepared as geochemical reference standards for elemental and isotopic compositions. Powdered rock samples were examined by measuring delayed neutron emission after irradiation with a flux of the order of 10 to the 13th power neutrons/sq cm per sec in a nuclear reactor. The measurements are shown to compare quite favorably with previous uranium determinations for other standard rock samples.
The method for extracting and preparing a dust or soil sample for analysis of polar persistent organic pollutants is summarized in this SOP. It covers the extraction, concentration, and derivatization of samples that are to be analyzed by gas chromatography/mass spectrometry.
The method for extracting and preparing urine samples for analysis of hydroxy-polycyclic aromatic hydrocarbons, pentachlorophenol and 2,4-D is summarized in this SOP. It covers the extraction, concentration and methylation of samples that are to be analyzed by gas chromatography/...
A novel tool to standardize rheology testing of molten polymers for pharmaceutical applications.
Treffer, Daniel; Troiss, Alexander; Khinast, Johannes
2015-11-10
Melt rheology provides information about material properties that are of great importance for equipment design and simulations, especially for novel pharmaceutical manufacturing operations, including extrusion, injection molding or 3d printing. To that end, homogeneous samples must be prepared, most commonly via compression or injection molding, both of which require costly equipment and might not be applicable for shear- and heat-sensitive pharmaceutical materials. Our study introduces a novel vacuum compression molding (VCM) tool for simple preparation of thermoplastic specimens using standard laboratory equipment: a hot plate and a vacuum source. Sticking is eliminated by applying polytetrafluoroethylene (PTFE) coated separation foils. The evacuation of the tool leads to compression of the sample chamber, which is cost-efficient compared to conventional methods, such as compression molding or injection molding that require special equipment. In addition, this compact design reduces the preparation time and the heat load. The VCM tool was used to prepare samples for a rheological study of three pharmaceutical polymers (Soluplus(®), Eudragit(®)E, EVA Rowalit(®) 300-1/28). The prepared samples were without any air inclusions or voids, and the measurements had a high reproducibility. All relative standard deviations were below 3%. The obtained data were fitted to the Carreau-Yasuda model and time-temperature superposition was applied. Copyright © 2015 Elsevier B.V. All rights reserved.
Effects of Sample Preparation on the Infrared Reflectance Spectra of Powders
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brauer, Carolyn S.; Johnson, Timothy J.; Myers, Tanya L.
2015-05-22
While reflectance spectroscopy is a useful tool in identifying molecular compounds, laboratory measurement of solid (particularly powder) samples often is confounded by sample preparation methods. For example, both the packing density and surface roughness can have an effect on the quantitative reflectance spectra of powdered samples. Recent efforts in our group have focused on developing standard methods for measuring reflectance spectra that accounts for sample preparation, as well as other factors such as particle size and provenance. In this work, the effect of preparation method on sample reflectivity was investigated by measuring the directional-hemispherical spectra of samples that were hand-packedmore » as well as pressed into pellets using an integrating sphere attached to a Fourier transform infrared spectrometer. The results show that the methods used to prepare the sample have a substantial effect on the measured reflectance spectra, as do other factors such as particle size.« less
Effects of sample preparation on the infrared reflectance spectra of powders
NASA Astrophysics Data System (ADS)
Brauer, Carolyn S.; Johnson, Timothy J.; Myers, Tanya L.; Su, Yin-Fong; Blake, Thomas A.; Forland, Brenda M.
2015-05-01
While reflectance spectroscopy is a useful tool for identifying molecular compounds, laboratory measurement of solid (particularly powder) samples often is confounded by sample preparation methods. For example, both the packing density and surface roughness can have an effect on the quantitative reflectance spectra of powdered samples. Recent efforts in our group have focused on developing standard methods for measuring reflectance spectra that accounts for sample preparation, as well as other factors such as particle size and provenance. In this work, the effect of preparation method on sample reflectivity was investigated by measuring the directional-hemispherical spectra of samples that were hand-loaded as well as pressed into pellets using an integrating sphere attached to a Fourier transform infrared spectrometer. The results show that the methods used to prepare the sample can have a substantial effect on the measured reflectance spectra, as do other factors such as particle size.
Sample Preparation for Electron Probe Microanalysis—Pushing the Limits
Geller, Joseph D.; Engle, Paul D.
2002-01-01
There are two fundamental considerations in preparing samples for electron probe microanalysis (EPMA). The first one may seem obvious, but we often find it is overlooked. That is, the sample analyzed should be representative of the population from which it comes. The second is a direct result of the assumptions in the calculations used to convert x-ray intensity ratios, between the sample and standard, to concentrations. Samples originate from a wide range of sources. During their journey to being excited under the electron beam for the production of x rays there are many possibilities for sample alteration. Handling can contaminate samples by adding extraneous matter. In preparation, the various abrasives used in sizing the sample by sawing, grinding and polishing can embed themselves. The most accurate composition of a contaminated sample is, at best, not representative of the original sample; it is misleading. Our laboratory performs EPMA analysis on customer submitted samples and prepares over 250 different calibration standards including pure elements, compounds, alloys, glasses and minerals. This large variety of samples does not lend itself to mass production techniques, including automatic polishing. Our manual preparation techniques are designed individually for each sample. The use of automated preparation equipment does not lend itself to this environment, and is not included in this manuscript. The final step in quantitative electron probe microanalysis is the conversion of x-ray intensities ratios, known as the “k-ratios,” to composition (in mass fraction or atomic percent) and/or film thickness. Of the many assumptions made in the ZAF (where these letters stand for atomic number, absorption and fluorescence) corrections the localized geometry between the sample and electron beam, or takeoff angle, must be accurately known. Small angular errors can lead to significant errors in the final results. The sample preparation technique then becomes very important, and, under certain conditions, may even be the limiting factor in the analytical uncertainty budget. This paper considers preparing samples to get known geometries. It will not address the analysis of samples with irregular, unprepared surfaces or unknown geometries. PMID:27446757
NASA Astrophysics Data System (ADS)
Wrable-Rose, Madeline; Primera-Pedrozo, Oliva M.; Pacheco-Londoño, Leonardo C.; Hernandez-Rivera, Samuel P.
2010-12-01
This research examines the surface contamination properties, trace sample preparation methodologies, detection systems response and generation of explosive contamination standards for trace detection systems. Homogeneous and reproducible sample preparation is relevant for trace detection of chemical threats, such as warfare agents, highly energetic materials (HEM) and toxic industrial chemicals. The objective of this research was to develop a technology capable of producing samples and standards of HEM with controlled size and distribution on a substrate to generate specimens that would reproduce real contamination conditions. The research activities included (1) a study of the properties of particles generated by two deposition techniques: sample smearing deposition and inkjet deposition, on gold-coated silicon, glass and stainless steel substrates; (2) characterization of composition, distribution and adhesion characteristics of deposits; (3) evaluation of accuracy and reproducibility for depositing neat highly energetic materials such as TNT, RDX and ammonium nitrate; (4) a study of HEM-surface interactions using FTIR-RAIRS; and (5) establishment of protocols for validation of surface concentration using destructive methods such as HPLC.
Preparation and application of in-fibre internal standardization solid-phase microextraction.
Zhao, Wennan; Ouyang, Gangfeng; Pawliszyn, Janusz
2007-03-01
The in-fibre standardization method is a novel approach that has been developed for field sampling/sample preparation, in which an internal standard is pre-loaded onto a solid-phase microextraction (SPME) fibre for calibration of the extraction of target analytes in field samples. The same method can also be used for in-vial sample analysis. In this study, different techniques to load the standard to a non-porous SPME fibre were investigated. It was found that the appropriateness of the technique depends on the physical properties of the standards that are used for the analysis. Headspace extraction of the standard dissolved in pumping oil works well for volatile compounds. Conversely, headspace extraction of the pure standard is an effective approach for semi-volatile compounds. For compounds with low volatility, a syringe-fibre transfer method and direct extraction of the standard dissolved in a solvent exhibited a good reproducibility (<5% RSD). The main advantage of the approaches investigated in this study is that the standard generation vials can be reused for hundreds of analyses without exhibiting significant loss. Moreover, most of the standard loading processes studied can be performed automatically, which is efficient and precise. Finally, the standard loading technique and in-fibre standardization method were applied to a complex matrix (milk) and the results illustrated that the matrix effect can be effectively compensated for with this approach.
Khoomrung, Sakda; Chumnanpuen, Pramote; Jansa-ard, Suwanee; Nookaew, Intawat; Nielsen, Jens
2012-06-01
We present a fast and accurate method for preparation of fatty acid methyl esters (FAMEs) using microwave-assisted derivatization of fatty acids present in yeast samples. The esterification of free/bound fatty acids to FAMEs was completed within 5 min, which is 24 times faster than with conventional heating methods. The developed method was validated in two ways: (1) through comparison with a conventional method (hot plate) and (2) through validation with the standard reference material (SRM) 3275-2 omega-3 and omega-6 fatty acids in fish oil (from the Nation Institute of Standards and Technology, USA). There were no significant differences (P>0.05) in yields of FAMEs with both validations. By performing a simple modification of closed-vessel microwave heating, it was possible to carry out the esterification in Pyrex glass tubes kept inside the closed vessel. Hereby, we are able to increase the number of sample preparations to several hundred samples per day as the time for preparation of reused vessels was eliminated. Pretreated cell disruption steps are not required, since the direct FAME preparation provides equally quantitative results. The new microwave-assisted derivatization method facilitates the preparation of FAMEs directly from yeast cells, but the method is likely to also be applicable for other biological samples.
The International Standard for Oxytetracycline
Humphrey, J. H.; Lightbown, J. W.; Mussett, M. V.; Perry, W. L. M.
1955-01-01
The first attempt to set up an international standard for oxytetracycline, using oxytetracycline hydrochloride, failed because of difficulties in obtaining a preparation whose moisture content was uniform after distribution into ampoules. A preparation of dihydrate of oxytetracycline base was obtained instead, and was compared in an international collaborative assay with a sample of oxytetracycline hydrochloride, which was the current working standard of Chas. Pfizer & Co., Inc., USA. The results of the collaborative assay showed that the potency of the dihydrate was uniform, and that it was a suitable preparation for use as the International Standard. Evidence was obtained, however, that the reference preparation at the time of examination was less potent than had been originally supposed, and that it was hydrated. The potency of the proposed international standard was recalculated after allowance for water in the reference preparation, and the resulting biological potency agreed well with that to be expected on the basis of the physicochemical properties of the preparation. It was agreed, therefore, that the recalculated values should be used, and the preparation of oxytetracycline base dihydrate used in the collaborative assay is established as the International Standard for Oxytetracycline with a potency of 900 International Units per mg. PMID:13284563
Rhoderick, George C; Yen, James H
2006-05-01
Primary gravimetric gas cylinder standards containing 30 volatile organic compounds (VOCs) in nitrogen were prepared using a procedure previously developed to prepare gas mixture cylinder standards of VOCs at the 5 nmol/mol level. This set of primary standards was intercompared to existing gas cylinder standards, containing as many as 19 of the 30 volatile organics present in these new primaries, using gas chromatography with a hydrogen flame ionization detector coupled with cryogenic preconcentration. The linear regression analysis showed excellent agreement among the standards for each compound. Similar mixtures containing many of these compounds in treated aluminum gas cylinders have been evaluated over time and have shown stability for as much as 10 years. The development of these 30-component primary standards led to the preparation and certification of a reissue of Standard Reference Material (SRM) 1804 at the nominal amount-of-substance fraction of 5 nmol/mol for each analyte. A lot of 20 cylinders containing the mixture was prepared at NIST following previously demonstrated protocols for preparation of the cylinders. Each cylinder was analyzed against one cylinder from the lot, designated as the "lot standard," for each of the 30 compounds. As a result of the uncertainty analysis, the data showed that rather than declaring the lot homogeneous with a much higher uncertainty, each cylinder could be individually certified. The expanded uncertainty limits ranged from 1.5 to 10% for 28 of the 30 analytes, with two of the analytes having uncertainties as high as 19% in those SRM cylinders certified. Due to stability issues and some high uncertainties for a few analytes in 2 of the samples, 18 of the 20 candidate SRM samples were certified. These volatile organic gas mixtures represent the most complex gas SRMs developed at NIST.
Quality control evaluation of Keshamasi, Keshanjana and Keshamasi eye ointment.
Dhiman, Kartar Singh; Shukla, Vinay J; Bhalodia, Nayan R; Sharma, Vinay R
2014-01-01
Keshanjana (collyrium) is a well known Ayurvedic preparation prepared out of Keshamasi (ash prepared by scalp hairs) mixed with Goghrita (cow's ghee). This medicine is indicated for the treatment of Shushkakshipaka (dry eye syndrome) in the classical literature of Ayurveda; hence, it was under taken for standardization and clinical evaluation in an extra-mural research project from Central Council for Research in Ayurvedic Sciences, Department of AYUSH, New Delhi. To develop standard quality parameters for the Keshamasi, Keshanjana and Keshamasi ointment. Scalp hairs of male and females collected from saloons were converted to classical Masi Kalpana and mixed with cow ghee and petrolatum in the ratio of 1:5 to prepare the Keshanjana and Keshamasi ointment respectively. Standard Operation Procedure (SOP) were adopted and recorded accordingly. The raw material, furnished products and plain Goghrita were subjected for quality control parameters i.e., physico-chemical evaluation, anti-microbial study, particle size analysis, heavy metal analysis through inductive couple plasma spectroscopy with high performance thin layer liquid chromatography fingerprints. Rancidity was negative in all the samples, indicating that the physico-chemical parameters are in acceptable range. Lead and zinc were present in most of the samples; while all samples are were free from microbial contamination. As no standards are available to compare the results of the current study, the observations cannot be compared. Thus the profile generated in the current study can be considered as standard to refer in future studies.
Quality control evaluation of Keshamasi, Keshanjana and Keshamasi eye ointment
Dhiman, Kartar Singh; Shukla, Vinay J.; Bhalodia, Nayan R.; Sharma, Vinay R.
2014-01-01
Background: Keshanjana (collyrium) is a well known Ayurvedic preparation prepared out of Keshamasi (ash prepared by scalp hairs) mixed with Goghrita (cow's ghee). This medicine is indicated for the treatment of Shushkakshipaka (dry eye syndrome) in the classical literature of Ayurveda; hence, it was under taken for standardization and clinical evaluation in an extra-mural research project from Central Council for Research in Ayurvedic Sciences, Department of AYUSH, New Delhi. Aim: To develop standard quality parameters for the Keshamasi, Keshanjana and Keshamasi ointment. Materials and Methods: Scalp hairs of male and females collected from saloons were converted to classical Masi Kalpana and mixed with cow ghee and petrolatum in the ratio of 1:5 to prepare the Keshanjana and Keshamasi ointment respectively. Standard Operation Procedure (SOP) were adopted and recorded accordingly. The raw material, furnished products and plain Goghrita were subjected for quality control parameters i.e., physico-chemical evaluation, anti-microbial study, particle size analysis, heavy metal analysis through inductive couple plasma spectroscopy with high performance thin layer liquid chromatography fingerprints. Results: Rancidity was negative in all the samples, indicating that the physico-chemical parameters are in acceptable range. Lead and zinc were present in most of the samples; while all samples are were free from microbial contamination. Conclusion: As no standards are available to compare the results of the current study, the observations cannot be compared. Thus the profile generated in the current study can be considered as standard to refer in future studies. PMID:25364202
The purpose of this SOP is to describe methods for extracting and preparing an air sample consisting of a quartz fiber filter (Pallflex) and an XAD-2 cartridge for analysis of pesticides and polyaromatic hydrocarbons (PAHs). It covers the preparation of samples that are to be an...
TruSeq Stranded mRNA and Total RNA Sample Preparation Kits
Total RNA-Seq enabled by ribosomal RNA (rRNA) reduction is compatible with formalin-fixed paraffin embedded (FFPE) samples, which contain potentially critical biological information. The family of TruSeq Stranded Total RNA sample preparation kits provides a unique combination of unmatched data quality for both mRNA and whole-transcriptome analyses, robust interrogation of both standard and low-quality samples and workflows compatible with a wide range of study designs.
Quantitative LIBS analysis of vanadium in samples of hexagonal mesoporous silica catalysts.
Pouzar, Miloslav; Kratochvíl, Tomás; Capek, Libor; Smoláková, Lucie; Cernohorský, Tomás; Krejcová, Anna; Hromádko, Ludek
2011-02-15
The method for the analysis of vanadium in hexagonal mesoporous silica (V-HMS) catalysts using Laser Induced Breakdown Spectrometry (LIBS) was suggested. Commercially available LIBS spectrometer was calibrated with the aid of authentic V-HMS samples previously analyzed by ICP OES after microwave digestion. Deposition of the sample on the surface of adhesive tape was adopted as a sample preparation method. Strong matrix effect connected with the catalyst preparation technique (1st vanadium added in the process of HMS synthesis, 2nd already synthesised silica matrix was impregnated by vanadium) was observed. The concentration range of V in the set of nine calibration standards was 1.3-4.5% (w/w). Limit of detection was 0.13% (w/w) and it was calculated as a triple standard deviation from five replicated determinations of vanadium in the real sample with a very low vanadium concentration. Comparable results of LIBS and ED XRF were obtained if the same set of standards was used for calibration of both methods and vanadium was measured in the same type of real samples. LIBS calibration constructed using V-HMS-impregnated samples failed for measuring of V-HMS-synthesized samples. LIBS measurements seem to be strongly influenced with different chemical forms of vanadium in impregnated and synthesised samples. The combination of LIBS and ED XRF is able to provide new information about measured samples (in our case for example about procedure of catalyst preparation). Copyright © 2010 Elsevier B.V. All rights reserved.
The Third International Standard for Corticotrophin
Bangham, D. R.; Mussett, M. V.; Stack-Dunne, M. P.
1962-01-01
At its meeting in September 1957, the WHO Expert Committee on Biological Standardization agreed with the recommendation of the International Conference on Corticotrophin, held in July 1957, that a new international standard for corticotrophin should be set up, since the Second International Standard was made from crude material and was unsuitable for the assay of the purer preparations of corticotrophin now in general clinical use. In this paper, the authors describe the steps taken to establish the Third International Standard for Corticotrophin, from the preparation and international collaborative assay of the new material to the choice of the ”subcutaneous assay” for deriving the potency. The clinical and pharmacological implications of this choice are discussed. Since the preparation, characterization and exact quantitative assay of standards for corticotrophin are so difficult, several batches of approximately 3500 ampoules were prepared in a similar way from the same material to serve as an international Working Standard. Samples from two batches were included in the collaborative assay and found to have the same potency as the Third Standard. Sufficient ampoules of the Working Standard are available for use as national and laboratory standards. PMID:13966359
Determination of benzylpenicillin in pharmaceuticals by capillary zone electrophoresis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoyt, A.M. Jr.; Sepaniak, M.J.
A rapid and direct method is described for the determination of benzylpenicillin (penicillin G) in pharmaceutical preparations. The method involves very little sample preparation and total analysis time for duplicate results is less 30 minutes per sample. The method takes advantage of the speed and separating power of capillary zone electrophoresis (CZE). Detection of penicillin is by absorption at 228 nm. An internal standard is employed to reduce sample injection error. The method was applied successfully to both tablets and injectable preparations. 14 refs., 5 figs., 3 tabs.
MARS: bringing the automation of small-molecule bioanalytical sample preparations to a new frontier.
Li, Ming; Chou, Judy; Jing, Jing; Xu, Hui; Costa, Aldo; Caputo, Robin; Mikkilineni, Rajesh; Flannelly-King, Shane; Rohde, Ellen; Gan, Lawrence; Klunk, Lewis; Yang, Liyu
2012-06-01
In recent years, there has been a growing interest in automating small-molecule bioanalytical sample preparations specifically using the Hamilton MicroLab(®) STAR liquid-handling platform. In the most extensive work reported thus far, multiple small-molecule sample preparation assay types (protein precipitation extraction, SPE and liquid-liquid extraction) have been integrated into a suite that is composed of graphical user interfaces and Hamilton scripts. Using that suite, bioanalytical scientists have been able to automate various sample preparation methods to a great extent. However, there are still areas that could benefit from further automation, specifically, the full integration of analytical standard and QC sample preparation with study sample extraction in one continuous run, real-time 2D barcode scanning on the Hamilton deck and direct Laboratory Information Management System database connectivity. We developed a new small-molecule sample-preparation automation system that improves in all of the aforementioned areas. The improved system presented herein further streamlines the bioanalytical workflow, simplifies batch run design, reduces analyst intervention and eliminates sample-handling error.
Lack of latex allergen contamination of solutions withdrawn from vials with natural rubber stoppers.
Thomsen, D J; Burke, T G
2000-01-01
The effect on latex allergen contamination and microbial growth of a latex-allergy precaution technique for preparing injectable products was studied. The study consisted of three parts: (1) preparation of 20 samples from vials with latex-containing stoppers in accordance with conventional guidelines, (2) preparation of 20 samples in accordance with latex-allergy precaution guidelines, and (3) preparation of 5 latex-free samples and 1 latex-contaminated sample as negative and positive controls, respectively. The conventional method involved swabbing a vial top with an alcohol prep pad, puncturing the dry natural rubber stopper with an 18-gauge needle attached to a latex-free syringe, and withdrawing the contents of the vial into the syringe. The latex-allergy precaution preparation technique was similar, except that the stopper was removed before the vial contents were withdrawn. There was essentially no difference in latex allergen concentrations between the two drug preparation methods. None of the samples prepared with the standard method supported any microbial growth. One sample prepared with the latex-allergy precaution method grew bacteria. Removal of the dry rubber stopper from vials did not yield solutions with less latex allergen than solutions prepared according to conventional guidelines.
Ashley, Kevin; Brisson, Michael J; Howe, Alan M; Bartley, David L
2009-12-01
A collaborative interlaboratory evaluation of a newly standardized inductively coupled plasma mass spectrometry (ICP-MS) method for determining trace beryllium in workplace air samples was carried out toward fulfillment of method validation requirements for ASTM International voluntary consensus standard test methods. The interlaboratory study (ILS) was performed in accordance with an applicable ASTM International standard practice, ASTM E691, which describes statistical procedures for investigating interlaboratory precision. Uncertainty was also estimated in accordance with ASTM D7440, which applies the International Organization for Standardization Guide to the Expression of Uncertainty in Measurement to air quality measurements. Performance evaluation materials (PEMs) used consisted of 37 mm diameter mixed cellulose ester filters that were spiked with beryllium at levels of 0.025 (low loading), 0.5 (medium loading), and 10 (high loading) microg Be/filter; these spiked filters were prepared by a contract laboratory. Participating laboratories were recruited from a pool of over 50 invitees; ultimately, 20 laboratories from Europe, North America, and Asia submitted ILS results. Triplicates of each PEM (blanks plus the three different loading levels) were conveyed to each volunteer laboratory, along with a copy of the draft standard test method that each participant was asked to follow; spiking levels were unknown to the participants. The laboratories were requested to prepare the PEMs by one of three sample preparation procedures (hotplate or microwave digestion or hotblock extraction) that were described in the draft standard. Participants were then asked to analyze aliquots of the prepared samples by ICP-MS and to report their data in units of mu g Be/filter sample. Interlaboratory precision estimates from participating laboratories, computed in accordance with ASTM E691, were 0.165, 0.108, and 0.151 (relative standard deviation) for the PEMs spiked at 0.025, 0.5, and 10 microg Be/filter, respectively. Overall recoveries were 93.2%, 102%, and 80.6% for the low, medium, and high beryllium loadings, respectively. Expanded uncertainty estimates for interlaboratory analysis of low, medium, and high beryllium loadings, calculated in accordance with ASTM D7440, were 18.8%, 19.8%, and 24.4%, respectively. These figures of merit support promulgation of the analytical procedure as an ASTM International standard test method, ASTM D7439.
40 CFR 761.392 - Preparing validation study samples.
Code of Federal Regulations, 2014 CFR
2014-07-01
... establish a surface concentration to be included in the standard operating procedure. The surface levels of... Under § 761.79(d)(4) § 761.392 Preparing validation study samples. (a)(1) To validate a procedure to... surfaces must be ≥20 µg/100 cm2. (2) To validate a procedure to decontaminate a specified surface...
40 CFR 761.392 - Preparing validation study samples.
Code of Federal Regulations, 2012 CFR
2012-07-01
... establish a surface concentration to be included in the standard operating procedure. The surface levels of... Under § 761.79(d)(4) § 761.392 Preparing validation study samples. (a)(1) To validate a procedure to... surfaces must be ≥20 µg/100 cm2. (2) To validate a procedure to decontaminate a specified surface...
40 CFR 761.392 - Preparing validation study samples.
Code of Federal Regulations, 2013 CFR
2013-07-01
... establish a surface concentration to be included in the standard operating procedure. The surface levels of... Under § 761.79(d)(4) § 761.392 Preparing validation study samples. (a)(1) To validate a procedure to... surfaces must be ≥20 µg/100 cm2. (2) To validate a procedure to decontaminate a specified surface...
The purpose of this SOP is to describe the stages of preparation required for Harvard particulate matter (PM) sampler impactor: (1) prior to in-field use of the particulate sampling system, (2) in-field sampling, and (3) disassembly after field use. This procedure applies direct...
Wood, Jessica L; Steiner, Robert R
2011-06-01
Forensic analysis of pharmaceutical preparations requires a comparative analysis with a standard of the suspected drug in order to identify the active ingredient. Purchasing analytical standards can be expensive or unattainable from the drug manufacturers. Direct Analysis in Real Time (DART™) is a novel, ambient ionization technique, typically coupled with a JEOL AccuTOF™ (accurate mass) mass spectrometer. While a fast and easy technique to perform, a drawback of using DART™ is the lack of component separation of mixtures prior to ionization. Various in-house pharmaceutical preparations were purified using thin-layer chromatography (TLC) and mass spectra were subsequently obtained using the AccuTOF™- DART™ technique. Utilizing TLC prior to sample introduction provides a simple, low-cost solution to acquiring mass spectra of the purified preparation. Each spectrum was compared against an in-house molecular formula list to confirm the accurate mass elemental compositions. Spectra of purified ingredients of known pharmaceuticals were added to an in-house library for use as comparators for casework samples. Resolving isomers from one another can be accomplished using collision-induced dissociation after ionization. Challenges arose when the pharmaceutical preparation required an optimized TLC solvent to achieve proper separation and purity of the standard. Purified spectra were obtained for 91 preparations and included in an in-house drug standard library. Primary standards would only need to be purchased when pharmaceutical preparations not previously encountered are submitted for comparative analysis. TLC prior to DART™ analysis demonstrates a time efficient and cost saving technique for the forensic drug analysis community. Copyright © 2011 John Wiley & Sons, Ltd. Copyright © 2011 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Sydoff, Marie; Stenström, Kristina
2010-04-01
The Department of Physics at Lund University is participating in a European Union project called EUMAPP (European Union Microdose AMS Partnership Programme), in which sample preparation and accelerator mass spectrometry (AMS) measurements of biological samples from microdosing studies have been made. This paper describes a simplified method of converting biological samples to solid graphite for 14C analysis with AMS. The method is based on online combustion of the samples, and reduction of CO 2 in septa-sealed vials. The septa-sealed vials and disposable materials are used to eliminate sample cross-contamination. Measurements of ANU and Ox I standards show deviations of 2% and 3%, respectively, relative to reference values. This level of accuracy is sufficient for biological samples from microdosing studies. Since the method has very few handling steps from sample to graphite, the risk of failure during the sample preparation process is minimized, making the method easy to use in routine preparation of samples.
A Study in Enzyme Kinetics Using an Ion-Specific Electrode.
ERIC Educational Resources Information Center
Turchi, Sandra; And Others
1989-01-01
Describes an undergraduate biochemistry laboratory experiment on enzyme kinetics using the D-amino acid oxidase system and an ammonia electrode. Preparation of an ammonia standard curve, a sample preparation, and inhibition studies are discussed. (YP)
Gauw, R D; Stoffolano, P J; Kuhlenbeck, D L; Patel, V S; Garver, S M; Baker, T R; Wehmeyer, K R
2000-07-21
Semi-automated 96-well plate solid-phase extraction (SPE) was used for sample preparation of fluprostenol, a prostaglandin analog, in rat plasma prior to detection by gas chromatography-negative chemical ionization tandem mass spectrometry (GC-NCI-MS-MS). A liquid handling system was utilized for all aspects of sample handling prior to SPE including transferring of samples into a 96-well format, preparation of standards as well as addition of internal standard to standards, quality control samples and study samples. SPE was performed in a 96-well plate format using octadecylsilane packing and the effluent from the SPE was dried in a custom-made 96-well apparatus. The sample residue was derivatized sequentially with pentafluorobenzylbromide followed by N-methyl-N-trimethylsilyltrifluoroacetamide. The derivatized sample was then analyzed using GC-NCI-MS-MS. The dynamic range for the method was from 7 to 5800 pg/ml with a 0.1-ml plasma sample. The methodology was evaluated over a 4-day period and demonstrated an accuracy of 90-106% with a precision of 2.4-12.9%.
The purpose of this SOP is to describe the stages of preparation required for Harvard particulate matter (PM) sampler impactor: (1) prior to in-field use of the particulate sampling system, (2) in-field sampling, and (3) disassembly after field use. This procedure applies direct...
[Bacteriological quality of air in a ward for sterile pharmaceutical preparations].
Caorsi P, Beatriz; Sakurada Z, Andrea; Ulloa F, M Teresa; Pezzani V, Marcela; Latorre O, Paz
2011-02-01
An extremely clean area is required for preparation of sterile pharmaceutical compounds, in compliance with international standards, to minimize the probability of microbial contamination. To evaluate the bacteriological quality of the air in the Sterile Pharmaceutical Preparation Unit of the University of Chile's Clinical Hospital and to set up alerts and action levels of bacterial growth. We studied eight representative sites of our Unit on a daily basis from January to February 2005 and twice a week from June 2005 to February 2006. We collected 839 samples of air by impact in the Petri dish. 474 (56.5%) samples were positive; 17 (3.5%) of them had an inappropriate bacterial growth (2% of total samples). The samples from sites 1 and 2 (big and small biosafety cabinets) were negative. The countertop and transfer area occasionally exceeded the bacterial growth limits. The most frequently isolated bacteria were coagulase-negative staphylococci, Micrococcus spp and Corynebacterium spp, from skin microbiota, and Bacillus spp, an environmental bacteria. From a microbiological perspective, the air quality in our sterile preparation unit complied with international standards. Setting institutional alerts and action levels and appropriately identifying bacteria in sensitive areas permits quantification of the microbial load and application of preventive measures.
Sapozhnikova, Yelena; Simons, Tawana; Lehotay, Steven J
2015-05-13
A simple, fast, and cost-effective sample preparation method, previously developed and validated for the analysis of organic contaminants in fish using low-pressure gas chromatography-tandem mass spectrometry (LPGC-MS/MS), was evaluated for the analysis of polybrominated diphenyl ethers (PBDEs) and dichlorodiphenyltrichloroethane (DDT) pesticides using enzyme-linked immunosorbent assay (ELISA). The sample preparation technique was based on the quick, easy, cheap, rugged, effective, and safe (QuEChERS) approach with filter-vial dispersive solid phase extraction (d-SPE). Incurred PBDEs and DDTs were analyzed in three types of fish with 3-10% lipid content: Pacific croaker, salmon, and National Institute of Standards and Technology (NIST) Standard Reference Material 1947 (Lake Michigan fish tissue). LPGC-MS/MS and ELISA results were in agreement: 108-111 and 65-82% accuracy ELISA versus LPGC-MS/MS results for PBDEs and DDTs, respectively. Similar detection limits were achieved for ELISA and LPGC-MS/MS. Matrix effects (MEs) were significant (e.g., -60%) for PBDE measurement in ELISA, but not a factor in the case of DDT pesticides. This study demonstrated that the sample preparation method can be adopted for semiquantitative screening analysis of fish samples by commercial kits for PBDEs and DDTs.
NASA Astrophysics Data System (ADS)
Mandic, M.; Stöbener, N.; Smajgl, D.
2017-12-01
For many decades different instrumental methods involving generations of the isotope ratio mass spectrometers with different periphery units for sample preparation, have provided scientifically required high precision, and high throughput of samples for varies application - from geological and hydrological to food and forensic. With this work we introduce automated measurement of δ13C and δ18O from solid carbonate samples, DIC and δ18O of water. We have demonstrated usage of a Thermo Scientific™ Delta Ray™ IRIS with URI Connect on certified reference materials and confirmed the high achievable accuracy and a precision better then <0.1‰ for both δ13C and δ18O, in the laboratory or the field with same precision and throughput of samples. With equilibration method for determination of δ18O in water samples, which we present in this work, achieved repeatability and accuracy are 0.12‰ and 0.68‰ respectively, which fulfill requirements of regulatory methods. The preparation of the samples for carbonate and DIC analysis on the Delta Ray IRIS with URI Connect is similar to the previously mentioned Gas Bench II methods. Samples are put into vials and phosphoric acid is added. The resulting sample-acid chemical reaction releases CO2 gas, which is then introduced into the Delta Ray IRIS via the Variable Volume. Three international standards of carbonate materials (NBS-18, NBS-19 and IAEA-CO-1) were analyzed. NBS-18 and NBS-19 were used as standards for calibration, and IAEA-CO-1 was treated as unknown. For water sample analysis equilibration method with 1% of CO2 in dry air was used. Test measurements and conformation of precision and accuracy of method determination δ18O in water samples were done with three lab standards, namely ANST, OCEAN 2 and HBW. All laboratory standards were previously calibrated with international reference material VSMOW2 and SLAP2 to assure accuracy of the isotopic values. The Principle of Identical Treatment was applied in sample and standard preparation, in measurement procedure, as well as in the evaluation of the results.
Wang, Guiqin; Wu, Yangsiqian; Lin, Yangting
2016-02-28
Nearly 99% of the total content of extraterrestrial metals is composed of Fe and Ni, but with greatly variable trace element contents. The accuracy obtained in the inductively coupled plasma mass spectrometry (ICP-MS) analysis of solutions of these samples can be significantly influenced by matrix contents, polyatomic ion interference, and the concentrations of external standard solutions. An ICP-MS instrument (X Series 2) was used to determine 30 standard solutions with different concentrations of trace elements, and different matrix contents. Based on these measurements, the matrix effects were determined. Three iron meteorites were dissolved separately in aqua regia and HNO3. Deviations due to variation of matrix contents in the external standard solutions were evaluated and the analysis results of the two digestion methods for iron meteorites were assessed. Our results show obvious deviations due to unmatched matrix contents in the external standard solutions. Furthermore, discrepancy in the measurement of some elements was found between the sample solutions prepared with aqua regia and HNO3, due to loss of chloride during sample preparation and/or incomplete digestion of highly siderophile elements in iron meteorites. An accurate ICP-MS analysis method for extraterrestrial metal samples has been established using external standard solutions with matched matrix contents and digesting the samples with HNO3 and aqua regia. Using the data from this work, the Mundrabilla iron meteorite previously classified as IAB-ung is reclassified as IAB-MG. Copyright © 2016 John Wiley & Sons, Ltd.
Separation of Be and Al for AMS using single-step column chromatography
NASA Astrophysics Data System (ADS)
Binnie, Steven A.; Dunai, Tibor J.; Voronina, Elena; Goral, Tomasz; Heinze, Stefan; Dewald, Alfred
2015-10-01
With the aim of simplifying AMS target preparation procedures for TCN measurements we tested a new extraction chromatography approach which couples an anion exchange resin (WBEC) to a chelating resin (Beryllium resin) to separate Be and Al from dissolved quartz samples. Results show that WBEC-Beryllium resin stacks can be used to provide high purity Be and Al separations using a combination of hydrochloric/oxalic and nitric acid elutions. 10Be and 26Al concentrations from quartz samples prepared using more standard procedures are compared with results from replicate samples prepared using the coupled WBEC-Beryllium resin approach and show good agreement. The new column procedure is performed in a single step, reducing sample preparation times relative to more traditional methods of TCN target production.
Hughes, Sarah A; Huang, Rongfu; Mahaffey, Ashley; Chelme-Ayala, Pamela; Klamerth, Nikolaus; Meshref, Mohamed N A; Ibrahim, Mohamed D; Brown, Christine; Peru, Kerry M; Headley, John V; Gamal El-Din, Mohamed
2017-11-01
There are several established methods for the determination of naphthenic acids (NAs) in waters associated with oil sands mining operations. Due to their highly complex nature, measured concentration and composition of NAs vary depending on the method used. This study compared different common sample preparation techniques, analytical instrument methods, and analytical standards to measure NAs in groundwater and process water samples collected from an active oil sands operation. In general, the high- and ultrahigh-resolution methods, namely high performance liquid chromatography time-of-flight mass spectrometry (UPLC-TOF-MS) and Orbitrap mass spectrometry (Orbitrap-MS), were within an order of magnitude of the Fourier transform infrared spectroscopy (FTIR) methods. The gas chromatography mass spectrometry (GC-MS) methods consistently had the highest NA concentrations and greatest standard error. Total NAs concentration was not statistically different between sample preparation of solid phase extraction and liquid-liquid extraction. Calibration standards influenced quantitation results. This work provided a comprehensive understanding of the inherent differences in the various techniques available to measure NAs and hence the potential differences in measured amounts of NAs in samples. Results from this study will contribute to the analytical method standardization for NA analysis in oil sands related water samples. Copyright © 2017 Elsevier Ltd. All rights reserved.
Zhang, Dan; Wang, Xiaolin; Liu, Man; Zhang, Lina; Deng, Ming; Liu, Huichen
2015-01-01
A rapid, sensitive and accurate ICP-MS method using alternate analyte-free matrix for calibration standards preparation and a rapid direct dilution procedure for sample preparation was developed and validated for the quantification of exogenous strontium (Sr) from the drug in human serum. Serum was prepared by direct dilution (1:29, v/v) in an acidic solution consisting of nitric acid (0.1%) and germanium (Ge) added as internal standard (IS), to obtain simple and high-throughput preparation procedure with minimized matrix effect, and good repeatability. ICP-MS analysis was performed using collision cell technology (CCT) mode. Alternate matrix method by using distilled water as an alternate analyte-free matrix for the preparation of calibration standards (CS) was used to avoid the influence of endogenous Sr in serum on the quantification. The method was validated in terms of selectivity, carry-over, matrix effects, lower limit of quantification (LLOQ), linearity, precision and accuracy, and stability. Instrumental linearity was verified in the range of 1.00-500ng/mL, corresponding to a concentration range of 0.0300-15.0μg/mL in 50μL sample of serum matrix and alternate matrix. Intra- and inter-day precision as relative standard deviation (RSD) were less than 8.0% and accuracy as relative error (RE) was within ±3.0%. The method allowed a high sample throughput, and was sensitive and accurate enough for a pilot bioequivalence study in healthy male Chinese subjects following single oral administration of two strontium ranelate formulations containing 2g strontium ranelate. Copyright © 2014 Elsevier GmbH. All rights reserved.
Validated method for quantification of genetically modified organisms in samples of maize flour.
Kunert, Renate; Gach, Johannes S; Vorauer-Uhl, Karola; Engel, Edwin; Katinger, Hermann
2006-02-08
Sensitive and accurate testing for trace amounts of biotechnology-derived DNA from plant material is the prerequisite for detection of 1% or 0.5% genetically modified ingredients in food products or raw materials thereof. Compared to ELISA detection of expressed proteins, real-time PCR (RT-PCR) amplification has easier sample preparation and detection limits are lower. Of the different methods of DNA preparation CTAB method with high flexibility in starting material and generation of sufficient DNA with relevant quality was chosen. Previous RT-PCR data generated with the SYBR green detection method showed that the method is highly sensitive to sample matrices and genomic DNA content influencing the interpretation of results. Therefore, this paper describes a real-time DNA quantification based on the TaqMan probe method, indicating high accuracy and sensitivity with detection limits of lower than 18 copies per sample applicable and comparable to highly purified plasmid standards as well as complex matrices of genomic DNA samples. The results were evaluated with ValiData for homology of variance, linearity, accuracy of the standard curve, and standard deviation.
A method for reducing the sloughing of thick blood films for malaria diagnosis.
Norgan, Andrew P; Arguello, Heather E; Sloan, Lynne M; Fernholz, Emily C; Pritt, Bobbi S
2013-07-08
The gold standard for malaria diagnosis is the examination of thick and thin blood films. Thick films contain 10 to 20 times more blood than thin films, correspondingly providing increased sensitivity for malaria screening. A potential complication of thick film preparations is sloughing of the blood droplet from the slide during staining or rinsing, resulting in the loss of sample. In this work, two methods for improving thick film slide adherence ('scratch' (SCM) and 'acetone dip' (ADM) methods) were compared to the 'standard method' (SM) of thick film preparation. Standardized blood droplets from 26 previously examined EDTA whole blood specimens (22 positive and four negative) were concurrently spread on glass slides using the SM, ADM, and SCM. For the SM and ADM prepared slides, the droplet was gently spread to an approximate 22 millimeters in diameter spot on the slide using the edge of a second glass slide. For the SCM, the droplet was spread by carefully grinding (or scratching) it into the slide with the point of a second glass slide. Slides were dried for one hour in a laminar flow hood. For the ADM, slides were dipped once in an acetone filled Coplin jar and allowed to air dry. All slides were then Giemsa-stained and examined in a blinded manner. Adherence was assessed by blinded reviewers. No significant or severe defects were observed for slides prepared with the SCM. In contrast, 8 slides prepared by the ADM and 3 prepared using the SM displayed significant or severe defects. Thick films prepared by the three methods were microscopically indistinguishable and concordant results (positive or negative) were obtained for the three methods. Estimated parasitaemia of the blood samples ranged from 25 to 429,169 parasites/μL of blood. The SCM is an inexpensive, rapid, and simple method that improves the adherence of thick blood films to standard glass slides without altering general slide preparation, microscopic appearance or interpretability. Using the SCM, thick films can be reliably examined less than two hours after sample receipt. This represents a significant diagnostic improvement over protocols requiring extended drying periods.
Flexible automated approach for quantitative liquid handling of complex biological samples.
Palandra, Joe; Weller, David; Hudson, Gary; Li, Jeff; Osgood, Sarah; Hudson, Emily; Zhong, Min; Buchholz, Lisa; Cohen, Lucinda H
2007-11-01
A fully automated protein precipitation technique for biological sample preparation has been developed for the quantitation of drugs in various biological matrixes. All liquid handling during sample preparation was automated using a Hamilton MicroLab Star Robotic workstation, which included the preparation of standards and controls from a Watson laboratory information management system generated work list, shaking of 96-well plates, and vacuum application. Processing time is less than 30 s per sample or approximately 45 min per 96-well plate, which is then immediately ready for injection onto an LC-MS/MS system. An overview of the process workflow is discussed, including the software development. Validation data are also provided, including specific liquid class data as well as comparative data of automated vs manual preparation using both quality controls and actual sample data. The efficiencies gained from this automated approach are described.
Cheesecake: a potential vehicle for salmonellosis?
Hao, Y Y; Scouten, A J; Brackett, R E
1999-01-01
This study was conducted to investigate the potential hazard of Salmonella Enteritidis surviving during the preparation and baking of cheesecake. Batters prepared with standard- and reduced-fat ingredients were inoculated with a 5-strain cocktail of S. Enteritidis (10 and 10(6) CFU/g) and were then baked according to a typical cheesecake recipe. After baking, the cheesecakes were refrigerated overnight before the survival of S. Enteritidis was determined either by direct plating or after enrichment. Samples (approximately 25 g each) were aseptically cut from the center, mid (6.35 cm from edge), and side (2.54 cm from edge) area of each cake for microbiological analysis. Proximate compositions (fat, moisture, protein, ash, pH, and water activity) of both raw batter and final baked cheesecakes were also determined. S. Enteritidis was able to survive baking of cheesecake when batter was inoculated with a high population (10(6) CFU/g) of S. Enteritidis regardless of whether standard-or reduced-fat ingredients were used. Three of nine standard- and four of nine reduced-fat cheesecake samples contained viable S. Enteritidis. In addition, one sample contained viable S. Enteritidis population detectable by direct plating (approximately 10 CFU per g of cake). This sample was taken from the center of a standard-fat cheesecake that was inoculated with a high population (10(6) CFU/g) of S. Enteritidis. Results of this study suggest that cheesecake prepared with eggs of low microbiological quality or cheesecake improperly handled or stored could serve as a vehicle for salmonellosis.
NASA Astrophysics Data System (ADS)
Manicke, Nicholas Edward; Abu-Rabie, Paul; Spooner, Neil; Ouyang, Zheng; Cooks, R. Graham
2011-09-01
A method is presented for the direct quantitative analysis of therapeutic drugs from dried blood spot samples by mass spectrometry. The method, paper spray mass spectrometry, generates gas phase ions directly from the blood card paper used to store dried blood samples without the need for complex sample preparation and separation; the entire time for preparation and analysis of blood samples is around 30 s. Limits of detection were investigated for a chemically diverse set of some 15 therapeutic drugs; hydrophobic and weakly basic drugs, such as sunitinib, citalopram, and verapamil, were found to be routinely detectable at approximately 1 ng/mL. Samples were prepared by addition of the drug to whole blood. Drug concentrations were measured quantitatively over several orders of magnitude, with accuracies within 10% of the expected value and relative standard deviation (RSD) of around 10% by prespotting an internal standard solution onto the paper prior to application of the blood sample. We have demonstrated that paper spray mass spectrometry can be used to quantitatively measure drug concentrations over the entire therapeutic range for a wide variety of drugs. The high quality analytical data obtained indicate that the technique may be a viable option for therapeutic drug monitoring.
A high-throughput semi-automated preparation for filtered synaptoneurosomes.
Murphy, Kathryn M; Balsor, Justin; Beshara, Simon; Siu, Caitlin; Pinto, Joshua G A
2014-09-30
Synaptoneurosomes have become an important tool for studying synaptic proteins. The filtered synaptoneurosomes preparation originally developed by Hollingsworth et al. (1985) is widely used and is an easy method to prepare synaptoneurosomes. The hand processing steps in that preparation, however, are labor intensive and have become a bottleneck for current proteomic studies using synaptoneurosomes. For this reason, we developed new steps for tissue homogenization and filtration that transform the preparation of synaptoneurosomes to a high-throughput, semi-automated process. We implemented a standardized protocol with easy to follow steps for homogenizing multiple samples simultaneously using a FastPrep tissue homogenizer (MP Biomedicals, LLC) and then filtering all of the samples in centrifugal filter units (EMD Millipore, Corp). The new steps dramatically reduce the time to prepare synaptoneurosomes from hours to minutes, increase sample recovery, and nearly double enrichment for synaptic proteins. These steps are also compatible with biosafety requirements for working with pathogen infected brain tissue. The new high-throughput semi-automated steps to prepare synaptoneurosomes are timely technical advances for studies of low abundance synaptic proteins in valuable tissue samples. Copyright © 2014 Elsevier B.V. All rights reserved.
Ligugnana, Roberto
2017-01-01
Chapter <797> issued by the United States Pharmacopeial Convention, Inc. is the standard for sterile compounding. It is designed to reduce the number of patient infections due to contaminated pharmaceutical preparation. This regulation applies to all staff who prepare compounded sterile preparations and all places where they are produced, including hospitals, clinics, pharmacies, and physician's offices. This article provides the history of environmental microbiology and provides a discussion on environmental microbiology sampling of air for pharmaceutical sterile compounding. Copyright© by International Journal of Pharmaceutical Compounding, Inc.
Standardization of Shirishavaleha with reference to physico-chemical characteristics.
Yadav, Shyamlal Singh; Galib; Patgiri, B J; Shukla, V J; Prajapati, P K
2011-10-01
Ten batches of Shirishavaleha were prepared by using Twak (Bark) and Sara (Heartwood) of Shirisha [Albizzia lebbeck Benth]. The adopted formulation was based on Shirisharishta of Bhaishajya Ratnavali. Though Shirisharishta has significant therapeutic effect in cases of Tamaka swasa, etc.; it has few difficulties during the pharmaceutical procedure like consuming long time, climatic influences etc. Considering these inconveniencies, the formulation composition has been converted in to Shirishavaleha. Avaleha has been prepared by using Twak and Sara of Shirisha. No significant differences were found in pharmaceutical aspects of both the samples of Shirishavaleha and the current method of preparation can be considered as standard. Attempts were also made to develop analytical profile of avaleha, which were almost similar in both the samples, except showing more Rf values in High Performance Thin Layer Chromatography profile of Sara group.
Standardization of Shirishavaleha with reference to physico-chemical characteristics
Yadav, Shyamlal Singh; Galib; Patgiri, B. J.; Shukla, V. J.; Prajapati, P. K.
2011-01-01
Ten batches of Shirishavaleha were prepared by using Twak (Bark) and Sara (Heartwood) of Shirisha [Albizzia lebbeck Benth]. The adopted formulation was based on Shirisharishta of Bhaishajya Ratnavali. Though Shirisharishta has significant therapeutic effect in cases of Tamaka swasa, etc.; it has few difficulties during the pharmaceutical procedure like consuming long time, climatic influences etc. Considering these inconveniencies, the formulation composition has been converted in to Shirishavaleha. Avaleha has been prepared by using Twak and Sara of Shirisha. No significant differences were found in pharmaceutical aspects of both the samples of Shirishavaleha and the current method of preparation can be considered as standard. Attempts were also made to develop analytical profile of avaleha, which were almost similar in both the samples, except showing more Rf values in High Performance Thin Layer Chromatography profile of Sara group. PMID:22661855
Uses and biases of volunteer water quality data
Loperfido, J.V.; Beyer, P.; Just, C.L.; Schnoor, J.L.
2010-01-01
State water quality monitoring has been augmented by volunteer monitoring programs throughout the United States. Although a significant effort has been put forth by volunteers, questions remain as to whether volunteer data are accurate and can be used by regulators. In this study, typical volunteer water quality measurements from laboratory and environmental samples in Iowa were analyzed for error and bias. Volunteer measurements of nitrate+nitrite were significantly lower (about 2-fold) than concentrations determined via standard methods in both laboratory-prepared and environmental samples. Total reactive phosphorus concentrations analyzed by volunteers were similar to measurements determined via standard methods in laboratory-prepared samples and environmental samples, but were statistically lower than the actual concentration in four of the five laboratory-prepared samples. Volunteer water quality measurements were successful in identifying and classifying most of the waters which violate United States Environmental Protection Agency recommended water quality criteria for total nitrogen (66%) and for total phosphorus (52%) with the accuracy improving when accounting for error and biases in the volunteer data. An understanding of the error and bias in volunteer water quality measurements can allow regulators to incorporate volunteer water quality data into total maximum daily load planning or state water quality reporting. ?? 2010 American Chemical Society.
[Determination of LF-VD refining furnace slag by X ray fluorescence spectrometry].
Kan, Bin; Cheng, Jian-ping; Song, Zu-feng
2004-10-01
Eight components, i.e. TFe, CaO, MgO, Al2O3, SiO2, TiO2, MnO and P2O5 in refining furnace slag were determined by X ray fluorescence spectrometer. Because the content of CaO was high, the authors selected 12 national and departmental grade slag standard samples and prepared a series of synthetic standard samples by adding spectrally pure reagents to them. The calibration curve is suitable to the sample analysis of CaO, MgO and SiO2 with widely varying range. Meanwhile, the points on the curve are even. The samples were prepared at high temperature by adding Li2B4O7 as flux. The experiments for the selection of the sample preparation conditions about strip reagents, melting temperature and dulition ratio were carried out. The matrix effects on absorption and enhancement were corrected by means of PH model and theoretical alpha coefficient. Moreover, the precision and accuracy experiments were performed. In comparison with chemical analysis method, the quantitative analytical results for each component are satisfactory. The method has proven rapid, precise and simple.
Seashols-Williams, Sarah; Green, Raquel; Wohlfahrt, Denise; Brand, Angela; Tan-Torres, Antonio Limjuco; Nogales, Francy; Brooks, J Paul; Singh, Baneshwar
2018-05-17
Sequencing and classification of microbial taxa within forensically relevant biological fluids has the potential for applications in the forensic science and biomedical fields. The quantity of bacterial DNA from human samples is currently estimated based on quantity of total DNA isolated. This method can miscalculate bacterial DNA quantity due to the mixed nature of the sample, and consequently library preparation is often unreliable. We developed an assay that can accurately and specifically quantify bacterial DNA within a mixed sample for reliable 16S ribosomal DNA (16S rDNA) library preparation and high throughput sequencing (HTS). A qPCR method was optimized using universal 16S rDNA primers, and a commercially available bacterial community DNA standard was used to develop a precise standard curve. Following qPCR optimization, 16S rDNA libraries from saliva, vaginal and menstrual secretions, urine, and fecal matter were amplified and evaluated at various DNA concentrations; successful HTS data were generated with as low as 20 pg of bacterial DNA. Changes in bacterial DNA quantity did not impact observed relative abundances of major bacterial taxa, but relative abundance changes of minor taxa were observed. Accurate quantification of microbial DNA resulted in consistent, successful library preparations for HTS analysis. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Kline, Margaret C; Duewer, David L; Travis, John C; Smith, Melody V; Redman, Janette W; Vallone, Peter M; Decker, Amy E; Butler, John M
2009-06-01
Modern highly multiplexed short tandem repeat (STR) assays used by the forensic human-identity community require tight control of the initial amount of sample DNA amplified in the polymerase chain reaction (PCR) process. This, in turn, requires the ability to reproducibly measure the concentration of human DNA, [DNA], in a sample extract. Quantitative PCR (qPCR) techniques can determine the number of intact stretches of DNA of specified nucleotide sequence in an extremely small sample; however, these assays must be calibrated with DNA extracts of well-characterized and stable composition. By 2004, studies coordinated by or reported to the National Institute of Standards and Technology (NIST) indicated that a well-characterized, stable human DNA quantitation certified reference material (CRM) could help the forensic community reduce within- and among-laboratory quantitation variability. To ensure that the stability of such a quantitation standard can be monitored and that, if and when required, equivalent replacement materials can be prepared, a measurement of some stable quantity directly related to [DNA] is required. Using a long-established conventional relationship linking optical density (properly designated as decadic attenuance) at 260 nm with [DNA] in aqueous solution, NIST Standard Reference Material (SRM) 2372 Human DNA Quantitation Standard was issued in October 2007. This SRM consists of three quite different DNA extracts: a single-source male, a multiple-source female, and a mixture of male and female sources. All three SRM components have very similar optical densities, and thus very similar conventional [DNA]. The materials perform very similarly in several widely used gender-neutral assays, demonstrating that the combination of appropriate preparation methods and metrologically sound spectrophotometric measurements enables the preparation and certification of quantitation [DNA] standards that are both maintainable and of practical utility.
Reference samples for the earth sciences
Flanagan, F.J.
1974-01-01
A revised list of reference samples of interest to geoscientists has been extended to include samples for the agronomist, the archaeologist and the environmentalist. In addition to the source from which standard samples may be obtained, references or pertinent notes for some samples are included. The number of rock reference samples is now almost adequate, and the variety of ore samples will soon be sufficient. There are very few samples for microprobe work. Oil shales will become more important because of the outlook for world petroleum resources. The dryland equivalent of a submarine basalt might be useful in studies of sea-floor spreading and of the geochemistry of basalts. The Na- and K-feldspars of BCS (British Chemical Standards-Bureau of Analysed Samples), NBS (National Bureau of Standards), and ANRT (Association Kationale de la Recherche Technique) could serve as trace-element standards if such data were available. Similarly, the present NBS flint and plastic clays, as well as their predecessors, might be useful for archaeological pottery studies. The International Decade for Ocean Exploration may stimulate the preparation of ocean-water standards for trace elements or pollutants and a standard for manganese nodules. ?? 1974.
The Effect of Directed Medical Play on Young Children's Pain and Distress during Burn Wound Care
Moore, Elizabeth R.; Bennett, Katherine; Dietrich, Mary S.; Wells, Nancy
2015-01-01
Directed medical play is used to reduce children's pain and distress during medical treatment. In this pilot study, young children who attended the burn clinic received either directed medical play provided by a child life specialist or standard preparation from the burn clinic nurse, to prepare for their first dressing change. Data were collected using validated instruments. Children who participated in medical play experienced less distress during their dressing change (M= 0.5, n=12) than those receiving standard preparation (M=2.0, n=9). Children who received standard care reported a 2 point increase in pain during the procedure whereas children who participated in medical play reported a 1 point increase. Change in parental anxiety was similar for both groups. Parent satisfaction was higher for caregivers who observed medical play than standard preparation. Although all findings were in the hypothesized direction, none were statically significant, most likely because of the small sample size. PMID:25631102
This procedure summarizes the sample shipping procedures that have been described in the individual NHEXAS sample collection protocols. This procedure serves as a quick reference tool for the field staff when samples are prepared for shipment at the field lab/staging area. For ea...
Klimek-Turek, A; Sikora, M; Rybicki, M; Dzido, T H
2016-03-04
A new concept of using thin-layer chromatography to sample preparation for the quantitative determination of solute/s followed by instrumental techniques is presented Thin-layer chromatography (TLC) is used to completely separate acetaminophen and its internal standard from other components (matrix) and to form a single spot/zone containing them at the solvent front position (after the final stage of the thin-layer chromatogram development). The location of the analytes and internal standard in the solvent front zone allows their easy extraction followed by quantitation by HPLC. The exctraction procedure of the solute/s and internal standard can proceed from whole solute frontal zone or its part without lowering in accuracy of quantitative analysis. Copyright © 2016 Elsevier B.V. All rights reserved.
Monakhova, Yulia B; Diehl, Bernd W K; Do, Tung X; Schulze, Margit; Witzleben, Steffen
2018-02-05
Apart from the characterization of impurities, the full characterization of heparin and low molecular weight heparin (LMWH) also requires the determination of average molecular weight, which is closely related to the pharmaceutical properties of anticoagulant drugs. To determine average molecular weight of these animal-derived polymer products, partial least squares regression (PLS) was utilized for modelling of diffused-ordered spectroscopy NMR data (DOSY) of a representative set of heparin (n=32) and LMWH (n=30) samples. The same sets of samples were measured by gel permeation chromatography (GPC) to obtain reference data. The application of PLS to the data led to calibration models with root mean square error of prediction of 498Da and 179Da for heparin and LMWH, respectively. The average coefficients of variation (CVs) did not exceed 2.1% excluding sample preparation (by successive measuring one solution, n=5) and 2.5% including sample preparation (by preparing and analyzing separate samples, n=5). An advantage of the method is that the sample after standard 1D NMR characterization can be used for the molecular weight determination without further manipulation. The accuracy of multivariate models is better than the previous results for other matrices employing internal standards. Therefore, DOSY experiment is recommended to be employed for the calculation of molecular weight of heparin products as a complementary measurement to standard 1D NMR quality control. The method can be easily transferred to other matrices as well. Copyright © 2017 Elsevier B.V. All rights reserved.
Nickerson, Beverly; Harrington, Brent; Li, Fasheng; Guo, Michele Xuemei
2017-11-30
Drug product assay is one of several tests required for new drug products to ensure the quality of the product at release and throughout the life cycle of the product. Drug product assay testing is typically performed by preparing a composite sample of multiple dosage units to obtain an assay value representative of the batch. In some cases replicate composite samples may be prepared and the reportable assay value is the average value of all the replicates. In previously published work by Harrington et al. (2014) [5], a sample preparation composite and replicate strategy for assay was developed to provide a systematic approach which accounts for variability due to the analytical method and dosage form with a standard error of the potency assay criteria based on compendia and regulatory requirements. In this work, this sample preparation composite and replicate strategy for assay is applied to several case studies to demonstrate the utility of this approach and its application at various stages of pharmaceutical drug product development. Copyright © 2017 Elsevier B.V. All rights reserved.
Oatts, Thomas J; Hicks, Cheryl E; Adams, Amy R; Brisson, Michael J; Youmans-McDonald, Linda D; Hoover, Mark D; Ashley, Kevin
2012-02-01
Occupational sampling and analysis for multiple elements is generally approached using various approved methods from authoritative government sources such as the National Institute for Occupational Safety and Health (NIOSH), the Occupational Safety and Health Administration (OSHA) and the Environmental Protection Agency (EPA), as well as consensus standards bodies such as ASTM International. The constituents of a sample can exist as unidentified compounds requiring sample preparation to be chosen appropriately, as in the case of beryllium in the form of beryllium oxide (BeO). An interlaboratory study was performed to collect analytical data from volunteer laboratories to examine the effectiveness of methods currently in use for preparation and analysis of samples containing calcined BeO powder. NIST SRM(®) 1877 high-fired BeO powder (1100 to 1200 °C calcining temperature; count median primary particle diameter 0.12 μm) was used to spike air filter media as a representative form of beryllium particulate matter present in workplace sampling that is known to be resistant to dissolution. The BeO powder standard reference material was gravimetrically prepared in a suspension and deposited onto 37 mm mixed cellulose ester air filters at five different levels between 0.5 μg and 25 μg of Be (as BeO). Sample sets consisting of five BeO-spiked filters (in duplicate) and two blank filters, for a total of twelve unique air filter samples per set, were submitted as blind samples to each of 27 participating laboratories. Participants were instructed to follow their current process for sample preparation and utilize their normal analytical methods for processing samples containing substances of this nature. Laboratories using more than one sample preparation and analysis method were provided with more than one sample set. Results from 34 data sets ultimately received from the 27 volunteer laboratories were subjected to applicable statistical analyses. The observed performance data show that sample preparations using nitric acid alone, or combinations of nitric and hydrochloric acids, are not effective for complete extraction of Be from the SRM 1877 refractory BeO particulate matter spiked on air filters; but that effective recovery can be achieved by using sample preparation procedures utilizing either sulfuric or hydrofluoric acid, or by using methodologies involving ammonium bifluoride with heating. Laboratories responsible for quantitative determination of Be in workplace samples that may contain high-fired BeO should use quality assurance schemes that include BeO-spiked sampling media, rather than solely media spiked with soluble Be compounds, and should ensure that methods capable of quantitative digestion of Be from the actual material present are used.
Stocka, Jolanta; Tankiewicz, Maciej; Biziuk, Marek; Namieśnik, Jacek
2011-01-01
Pesticides are among the most dangerous environmental pollutants because of their stability, mobility and long-term effects on living organisms. Their presence in the environment is a particular danger. It is therefore crucial to monitor pesticide residues using all available analytical methods. The analysis of environmental samples for the presence of pesticides is very difficult: the processes involved in sample preparation are labor-intensive and time-consuming. To date, it has been standard practice to use large quantities of organic solvents in the sample preparation process; but as these solvents are themselves hazardous, solvent-less and solvent-minimized techniques are becoming popular. The application of Green Chemistry principles to sample preparation is primarily leading to the miniaturization of procedures and the use of solvent-less techniques, and these are discussed in the paper. PMID:22174632
Emwas, Abdul-Hamid M; Al-Talla, Zeyad A; Kharbatia, Najeh M
2015-01-01
To maximize the utility of gas chromatography-mass spectrometry (GC-MS) in metabonomics research, all stages of the experimental design should be standardized, including sample collection, storage, preparation, and sample separation. Moreover, the prerequisite for any GC-MS analysis is that a compound must be volatile and thermally stable if it is to be analyzed using this technique. Since many metabolites are nonvolatile and polar in nature, they are not readily amenable to analysis by GC-MS and require initial chemical derivatization of the polar functional groups in order to reduce the polarity and to increase the thermal stability and volatility of the analytes. In this chapter, an overview is presented of the optimum approach to sample collection, storage, and preparation for gas chromatography-mass spectrometry-based metabonomics with particular focus on urine samples as example of biofluids.
Liao, Benjamin S; Sram, Jacqueline C; Files, Darin J
2013-01-01
A simple and effective anion ion chromatography (IC) method with anion exchange column and conductivity detector has been developed to determine free sulfites (SO3-2) in dried fruits processed with sulfur dioxide. No oxidation agent, such as hydrogen peroxide, is used to convert sulfites to sulfates for IC analysis. In addition, no stabilizing agent, such as formaldehyde, fructose or EDTA, is required during the sample extraction. This method uses aqueous 0.2 N NaOH as the solvent for standard preparation and sample extraction. The sulfites, either prepared from standard sodium sulfite powder or extracted from food samples, are presumed to be unbound SO3-2 in aqueous 0.2 N NaOH (pH > 13), because the bound sulfites in the sample matrix are released at pH > 10. In this study, sulfites in the standard solutions were stable at room temperature (i.e., 15-25 degrees C) for up to 12 days. The lowest standard of the linear calibration curve is set at 1.59 microg/mL SO3-2 (equivalent to 6.36 microg/g sample with no dilution) for analysis of processed dried fruits that would contain high levels (>1000 microg/g) of sulfites. As a consequence, this method typically requires significant dilution of the sample extract. Samples are prepared with a simple procedure of sample compositing, extraction with aqueous 0.2 N NaOH, centrifugation, dilution as needed, and filtration prior to IC. The sulfites in these sample extracts are stable at room temperature for up to 20 h. Using anion IC, the sulfites are eluted under isocratic conditions with 10 mM aqueous sodium carbonate solution as the mobile phase passing through an anion exchange column. The sulfites are easily separated, with an analysis run time of 18 min, regardless of the dried fruit matrix. Recoveries from samples spiked with sodium sulfites were demonstrated to be between 81 and 105% for five different fruit matrixes (apricot, golden grape, white peach, fig, and mango). Overall, this method is simple to perform and effective for the determination of high levels of sulfites in dried fruits.
Cheng, Dongwan; Zheng, Li; Hou, Junjie; Wang, Jifeng; Xue, Peng; Yang, Fuquan; Xu, Tao
2015-01-01
The absolute quantification of target proteins in proteomics involves stable isotope dilution coupled with multiple reactions monitoring mass spectrometry (SID-MRM-MS). The successful preparation of stable isotope-labeled internal standard peptides is an important prerequisite for the SID-MRM absolute quantification methods. Dimethyl labeling has been widely used in relative quantitative proteomics and it is fast, simple, reliable, cost-effective, and applicable to any protein sample, making it an ideal candidate method for the preparation of stable isotope-labeled internal standards. MRM mass spectrometry is of high sensitivity, specificity, and throughput characteristics and can quantify multiple proteins simultaneously, including low-abundance proteins in precious samples such as pancreatic islets. In this study, a new method for the absolute quantification of three proteases involved in insulin maturation, namely PC1/3, PC2 and CPE, was developed by coupling a stable isotope dimethyl labeling strategy for internal standard peptide preparation with SID-MRM-MS quantitative technology. This method offers a new and effective approach for deep understanding of the functional status of pancreatic β cells and pathogenesis in diabetes.
NEW COLUMN SEPARATION METHOD FOR EMERGENCY URINE SAMPLES
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maxwell, S; Brian Culligan, B
2007-08-28
The Savannah River Site Environmental Bioassay Lab participated in the 2007 NRIP Emergency Response program administered by the National Institute for Standards and Technology (NIST) in May, 2007. A new rapid column separation method was applied directly to the NRIP 2007 emergency urine samples, with only minimal sample preparation to reduce preparation time. Calcium phosphate precipitation, previously used to pre-concentrate actinides and Sr-90 in NRIP 2006 urine and water samples, was not used for the NRIP 2007 urine samples. Instead, the raw urine was acidified and passed directly through the stacked resin columns (TEVA+TRU+SR Resins) to separate the actinides andmore » strontium from the NRIP urine samples more quickly. This improvement reduced sample preparation time for the NRIP 2007 emergency urine analyses significantly. This approach works well for small volume urine samples expected during an emergency response event. Based on initial feedback from NIST, the SRS Environmental Bioassay Lab had the most rapid analysis times for actinides and strontium-90 analyses for NRIP 2007 urine samples.« less
Bonta, Maximilian; Török, Szilvia; Hegedus, Balazs; Döme, Balazs; Limbeck, Andreas
2017-03-01
Laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) is one of the most commonly applied methods for lateral trace element distribution analysis in medical studies. Many improvements of the technique regarding quantification and achievable lateral resolution have been achieved in the last years. Nevertheless, sample preparation is also of major importance and the optimal sample preparation strategy still has not been defined. While conventional histology knows a number of sample pre-treatment strategies, little is known about the effect of these approaches on the lateral distributions of elements and/or their quantities in tissues. The technique of formalin fixation and paraffin embedding (FFPE) has emerged as the gold standard in tissue preparation. However, the potential use for elemental distribution studies is questionable due to a large number of sample preparation steps. In this work, LA-ICP-MS was used to examine the applicability of the FFPE sample preparation approach for elemental distribution studies. Qualitative elemental distributions as well as quantitative concentrations in cryo-cut tissues as well as FFPE samples were compared. Results showed that some metals (especially Na and K) are severely affected by the FFPE process, whereas others (e.g., Mn, Ni) are less influenced. Based on these results, a general recommendation can be given: FFPE samples are completely unsuitable for the analysis of alkaline metals. When analyzing transition metals, FFPE samples can give comparable results to snap-frozen tissues. Graphical abstract Sample preparation strategies for biological tissues are compared with regard to the elemental distributions and average trace element concentrations.
Okamoto, Y
2000-06-01
The newly conceived electrothermal vaporization (ETV) system using a tungsten boat furnace (TBF) sample cuvette was designed for the direct analysis of solid samples with detection by inductively coupled plasma mass spectrometry (ICP-MS). Into this small sample cuvette, a solid mixture of the biological samples and diammonium hydrogenphosphate powder as a fusion flux was placed and situated on a TBF. Tetramethylammonium hydroxide solution was added to the mixture. After the on-furnace digestion had been completed, the analyte in the cuvette was vaporized and introduced into the ICP mass spectrometer. The solid samples were analyzed by using a calibration curve prepared from the aqueous standard solutions. The detection limit was estimated to be 5.1 pg of lead, which corresponds to 10.2 ng g(-1) of lead in solid samples when a prepared sample amount of 1.0 mg was applied. The relative standard deviation for 8 replicate measurements obtained with 100 pg of lead was calculated to be 6.5%. The analytical results for various biological samples are described.
Joshi, C; Dwivedi, A; Rai, S B
2014-08-14
Infrared-to-visible upconverting rare earths Er(3+)/Yb(3+) co-doped Y2O3 nano-crystalline phosphor samples have been prepared by solution combustion method followed by post-heat treatment at higher temperatures. A slight increase in average crystallite size has been found on calcinations verified by X-ray analysis. Transmission electron microscopy (TEM) confirms the nano-crystalline nature of the as-prepared and calcinated samples. Fourier transform infrared (FTIR) analysis shows the structural changes in as-prepared and calcinated samples. Upconversion and downconversion emission recorded using 976 and 532 nm laser sources clearly demonstrates a better luminescence properties in the calcinated samples as compared to as-prepared sample. Upconversion emission has been quantified in terms of standard chromaticity diagram (CIE) showing a shift in overall upconversion emission of as-prepared and calcinated samples. Temperature sensing behaviour of this material has also been investigated by measurement of fluorescence intensity ratio (FIR) of various signals in green emission in the temperature range of 315 to 555 K under 976 nm laser excitation. Copyright © 2014 Elsevier B.V. All rights reserved.
Grate, Jay W; Gonzalez, Jhanis J; O'Hara, Matthew J; Kellogg, Cynthia M; Morrison, Samuel S; Koppenaal, David W; Chan, George C-Y; Mao, Xianglei; Zorba, Vassilia; Russo, Richard E
2017-09-08
Solid sampling and analysis methods, such as laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), are challenged by matrix effects and calibration difficulties. Matrix-matched standards for external calibration are seldom available and it is difficult to distribute spikes evenly into a solid matrix as internal standards. While isotopic ratios of the same element can be measured to high precision, matrix-dependent effects in the sampling and analysis process frustrate accurate quantification and elemental ratio determinations. Here we introduce a potentially general solid matrix transformation approach entailing chemical reactions in molten ammonium bifluoride (ABF) salt that enables the introduction of spikes as tracers or internal standards. Proof of principle experiments show that the decomposition of uranium ore in sealed PFA fluoropolymer vials at 230 °C yields, after cooling, new solids suitable for direct solid sampling by LA. When spikes are included in the molten salt reaction, subsequent LA-ICP-MS sampling at several spots indicate that the spikes are evenly distributed, and that U-235 tracer dramatically improves reproducibility in U-238 analysis. Precisions improved from 17% relative standard deviation for U-238 signals to 0.1% for the ratio of sample U-238 to spiked U-235, a factor of over two orders of magnitude. These results introduce the concept of solid matrix transformation (SMT) using ABF, and provide proof of principle for a new method of incorporating internal standards into a solid for LA-ICP-MS. This new approach, SMT-LA-ICP-MS, provides opportunities to improve calibration and quantification in solids based analysis. Looking forward, tracer addition to transformed solids opens up LA-based methods to analytical methodologies such as standard addition, isotope dilution, preparation of matrix-matched solid standards, external calibration, and monitoring instrument drift against external calibration standards.
This SOP describes the procedures for homogenizing, extracting and concentrating solid food samples for persistent organic pollutants such as organochlorine compounds, organophosphate compounds, polycyclic aromatic hydrocarbons, polychlorinated biphenyls, substituted phenols, and...
This SOP describes the procedures for homogenizing, extracting, and concentrating liquid food samples for neutral persistent organic pollutants such as organochlorine compounds, organophosphate compounds, polycyclic aromatic hydrocarbons, polychlorinated biphenyls, and phenols.
Comparison of direct and indirect methods of measuring airborne chrysotile fibre concentration.
Eypert-Blaison, Celine; Veissiere, Sylvie; Rastoix, Olivier; Kauffer, Edmond
2010-01-01
Transmission electron microscopy observations most frequently form a basis for estimating asbestos fibre concentration in the environment and in buildings with asbestos-containing materials. Sampled fibres can be transferred to microscope grids by applying either a direct [ISO (1995) Draft International ISO/DIS 10312. Ambient air. Determination of asbestos fibres. Direct transfer transmission electron microscopy procedure. Geneva, Switzerland: International Standardization Organization] or an indirect [AFNOR (1996) Détermination de la concentration en fibres d'amiante par microscopie électronique à transmission-Méthode indirecte. Cedex, France: AFNOR, p. 42; ISO (1997) Draft International ISO/DIS 13794. Ambient air. Determination of asbestos fibres. Indirect-transfer transmission electron microscopy procedure. Geneva, Switzerland: International Standardization Organization] method. In the latter case, ISO Standard 13794 recommends filtering calcination residues either on a polycarbonate (PC) filter (PC indirect method) or on a cellulose ester (CE) membrane (CE indirect method). The PC indirect method requires that fibres deposited on a PC filter be covered by a carbon layer, whereas in the CE indirect method, the CE membrane has to be directly processed using a method described in ISO Standard 10312. The purpose of this study was to compare results obtained using, on the one hand, direct preparation methods and, on the other hand, PC indirect or CE indirect methods, for counting asbestos fibres deposited on filters as a result of liquid filtration or air sampling. In direct method-based preparation, we observed that an etching time of 6-14 min does not affect the measured densities, except for fibres <1 microm deposited by liquid filtration. Moreover, in all cases, the direct method gives higher densities than the PC indirect method because of possible fibre disappearance when using the carbon evaporator implemented in the PC indirect method. The CE membrane used for sample preparation in the CE indirect method is collapsed prior to passing it through the carbon evaporator, so the fibres are less likely to disappear at this stage. We then note that the resulting fibre densities for chrysotile-loaded filters prepared using the direct method are close to those obtained with filters prepared using the CE indirect method. Our study therefore shows that, under the implemented experimental conditions, the PC and CE indirect preparation methods described in ISO Standard 13794 are not equivalent.
Standardization of 237Np by the CIEMAT/NIST LSC tracer method
Gunther
2000-03-01
The standardization of 237Np presents some difficulties: several groups of alpha, beta and gamma radiation, chemical problems with the daughter nuclide 233Pa, an incomplete radioactive equilibrium after sample preparation, high conversion of some gamma transitions. To solve the chemical problems, a sample composition involving the Ultima Gold AB scintillator and a high concentration of HCl is used. Standardization by the CIEMAT/NIST method and by pulse shape discrimination is described. The results agree within 0.1% with those obtained by two other methods.
Method and apparatus for the preparation of liquid samples for determination of boron
Siemer, Darryl D.
1986-01-01
A method and apparatus for the preparation of a liquid sample for the quantitative determination of boron by flame photometry. The sample is combined in a vessel with sulfuric acid, and an excess of methanol is added thereto. The methanol reacts with any boron present in the sample to form trimethyl borate which is volatilized by the heat of reaction between the excess methanol and sulfuric acid. The volatilized trimethyl borate is withdrawn from the vessel by either a partial vacuum or a positive pressure and is rapidly transferred to a standard flame photometer. The method is free of interference from typical boron concomitants.
Method and apparatus for the preparation of liquid samples for determination of boron
Siemer, Darryl D.
1986-03-04
A method and apparatus for the preparation of a liquid sample for the quantitative determination of boron by flame photometry. The sample is combined in a vessel with sulfuric acid, and an excess of methanol is added thereto. The methanol reacts with any boron present in the sample to form trimethyl borate which is volatilized by the heat of reaction between the excess methanol and sulfuric acid. The volatilized trimethyl borate is withdrawn from the vessel by either a partial vacuum or a positive pressure and is rapidly transferred to a standard flame photometer. The method is free of interference from typical boron concomitants.
Method and apparatus for the preparation of liquid samples for determination of boron
Siemer, D.D.
A method and apparatus are described for the preparation of a liquid sample for the quantitative determination of boron by flame photometry. The sample is combined in a vessel with sulfuric acid, and an excess of methanol is added thereto. The methanol reacts with any boron present in the sample to form trimethyl borate which is volatilized by the heat of reaction between the excess methanol and sulfuric acid. The volatilized trimethyl borate is withdrawn from the vessel by either a partial vacuum or a positive pressure and is rapidly transferred to a standard flame photometer. The method is free of interference from typical boron concomitants.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maharrey, Sean P.; Highley, Aaron M.; Behrens, Richard, Jr.
2007-12-01
The objective of this short-term LDRD project was to acquire the tools needed to use our chemical imaging precision mass analyzer (ChIPMA) instrument to analyze tissue samples. This effort was an outgrowth of discussions with oncologists on the need to find the cellular origin of signals in mass spectra of serum samples, which provide biomarkers for ovarian cancer. The ultimate goal would be to collect chemical images of biopsy samples allowing the chemical images of diseased and nondiseased sections of a sample to be compared. The equipment needed to prepare tissue samples have been acquired and built. This equipment includesmore » an cyro-ultramicrotome for preparing thin sections of samples and a coating unit. The coating unit uses an electrospray system to deposit small droplets of a UV-photo absorbing compound on the surface of the tissue samples. Both units are operational. The tissue sample must be coated with the organic compound to enable matrix assisted laser desorption/ionization (MALDI) and matrix enhanced secondary ion mass spectrometry (ME-SIMS) measurements with the ChIPMA instrument Initial plans to test the sample preparation using human tissue samples required development of administrative procedures beyond the scope of this LDRD. Hence, it was decided to make two types of measurements: (1) Testing the spatial resolution of ME-SIMS by preparing a substrate coated with a mixture of an organic matrix and a bio standard and etching a defined pattern in the coating using a liquid metal ion beam, and (2) preparing and imaging C. elegans worms. Difficulties arose in sectioning the C. elegans for analysis and funds and time to overcome these difficulties were not available in this project. The facilities are now available for preparing biological samples for analysis with the ChIPMA instrument. Some further investment of time and resources in sample preparation should make this a useful tool for chemical imaging applications.« less
[Standard sample preparation method for quick determination of trace elements in plastic].
Yao, Wen-Qing; Zong, Rui-Long; Zhu, Yong-Fa
2011-08-01
Reference sample was prepared by masterbatch method, containing heavy metals with known concentration of electronic information products (plastic), the repeatability and precision were determined, and reference sample preparation procedures were established. X-Ray fluorescence spectroscopy (XRF) analysis method was used to determine the repeatability and uncertainty in the analysis of the sample of heavy metals and bromine element. The working curve and the metrical methods for the reference sample were carried out. The results showed that the use of the method in the 200-2000 mg x kg(-1) concentration range for Hg, Pb, Cr and Br elements, and in the 20-200 mg x kg(-1) range for Cd elements, exhibited a very good linear relationship, and the repeatability of analysis methods for six times is good. In testing the circuit board ICB288G and ICB288 from the Mitsubishi Heavy Industry Company, results agreed with the recommended values.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bhandari, Deepak; Van Berkel, Gary J
2012-01-01
The use of flow-injection electrospray ionization tandem mass spectrometry for rapid and high-throughput mass spectral analysis of selected B-vitamins, viz. B1, B2, B3, B5, and B6, in nutritional formulations was demonstrated. A simple and rapid (~5 min) in-tube sample preparation was performed by adding extraction solvent to a powdered sample aliquot followed by agitation, centrifugation, and filtration to recover an extract for analysis. Automated flow injection introduced 1 L of the extracts directly into the mass spectrometer ion source without chromatographic separation. Sample-to-sample analysis time was 60 s representing significant improvement over conventional liquid chromatography approaches which typically require 25-45more » min, and often require more significant sample preparation procedures. Quantitative capabilities of the flow-injection analysis were tested using the method of standard additions and NIST standard reference material (SRM 3280) multivitamin/multielement tablets. The quantity determined for each B-vitamin in SRM 3280 was within the statistical range provided for the respective certified values. The same sample preparation and analysis approach was also applied to two different commercial vitamin supplement tablets and proved to be successful in the quantification of the selected B-vitamins as evidenced by an agreement with the labels values and the results obtained using isotope dilution liquid chromatography/mass spectrometry.« less
Fernández, Beatriz; Rodríguez-González, Pablo; García Alonso, J Ignacio; Malherbe, Julien; García-Fonseca, Sergio; Pereiro, Rosario; Sanz-Medel, Alfredo
2014-12-03
We report on the determination of trace elements in solid samples by the combination of on-line double isotope dilution and laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). The proposed method requires the sequential analysis of the sample and a certified natural abundance standard by on-line IDMS using the same isotopically-enriched spike solution. In this way, the mass fraction of the analyte in the sample can be directly referred to the certified standard so the previous characterization of the spike solution is not required. To validate the procedure, Sr, Rb and Pb were determined in certified reference materials with different matrices, including silicate glasses (SRM 610, 612 and 614) and powdered samples (PACS-2, SRM 2710a, SRM 1944, SRM 2702 and SRM 2780). The analysis of powdered samples was carried out both by the preparation of pressed pellets and by lithium borate fusion. Experimental results for the analysis of powdered samples were in agreement with the certified values for all materials. Relative standard deviations in the range of 6-21% for pressed pellets and 3-21% for fused solids were obtained from n=3 independent measurements. Minimal sample preparation, data treatment and consumption of the isotopically-enriched isotopes are the main advantages of the method over previously reported approaches. Copyright © 2014 Elsevier B.V. All rights reserved.
Code of Federal Regulations, 2010 CFR
2010-01-01
... most recent years: (a) Prepared solution standardizations; (b) Recovery studies by known analyte... check sample testing or collaborative studies; (g) Daily critical parameter checks of equipment, such as...
Code of Federal Regulations, 2011 CFR
2011-01-01
... most recent years: (a) Prepared solution standardizations; (b) Recovery studies by known analyte... check sample testing or collaborative studies; (g) Daily critical parameter checks of equipment, such as...
Optical Methods for Identifying Hard Clay Core Samples During Petrophysical Studies
NASA Astrophysics Data System (ADS)
Morev, A. V.; Solovyeva, A. V.; Morev, V. A.
2018-01-01
X-ray phase analysis of the general mineralogical composition of core samples from one of the West Siberian fields was performed. Electronic absorption spectra of the clay core samples with an added indicator were studied. The speed and availability of applying the two methods in petrophysical laboratories during sample preparation for standard and special studies were estimated.
NASA Astrophysics Data System (ADS)
Manjili, Mohsen Hajipour; Halali, Mohammad
2018-02-01
Samples of INCONEL 718 were levitated and melted in a slag by the application of an electromagnetic field. The effects of temperature, time, and slag composition on the inclusion content of the samples were studied thoroughly. Samples were compared with the original alloy to study the effect of the process on inclusions. Size, shape, and chemical composition of remaining non-metallic inclusions were investigated. The samples were prepared by Standard Guide for Preparing and Evaluating Specimens for Automatic Inclusion Assessment of Steel (ASTM E 768-99) method and the results were reported by means of the Standard Test Methods for Determining the Inclusion Content of Steel (ASTM E 45-97). Results indicated that by increasing temperature and processing time, greater level of cleanliness could be achieved, and numbers and size of the remaining inclusions decreased significantly. It was also observed that increasing calcium fluoride content of the slag helped reduce inclusion content.
Interpretation of standard leaching test BS EN 12457-2: is your sample hazardous or inert?
Zandi, Mohammad; Russell, Nigel V; Edyvean, Robert G J; Hand, Russell J; Ward, Philip
2007-12-01
A slag sample from a lead refiner has been obtained and given to two analytical laboratories to determine the release of trace elements from the sample according to BS EN 12457-2. Samples analysed by one laboratory passed waste acceptance criteria, leading it to be classified as an inert material; samples of the same material analysed by the other laboratory failed waste acceptance criteria and were classified as hazardous. It was found that the sample preparation procedure is the critical step in the leaching analysis and that the effects of particle size on leachability should be taken into account when using this standard. The purpose of this paper is to open a debate on designing a better defined standard leaching test and making current waste acceptance criteria more flexible.
Standard test method for grindability of coal by the hardgrove-machine method
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1975-01-01
This method is used to determine the relative grindability or ease of pulverization of coals in comparison with coals chosen as standards. A prepared sample receives a definite amount of grinding energy in a miniature pulverizer, and the change in size consist is determined by sieving.
Jakob, Severin; Pfeifenberger, Manuel J.; Hohenwarter, Anton; Pippan, Reinhard
2017-01-01
Abstract The standard preparation technique for micro-sized samples is focused ion beam milling, most frequently using Ga+ ions. The main drawbacks are the required processing time and the possibility and risks of ion implantation. In contrast, ultrashort pulsed laser ablation can process any type of material with ideally negligible damage to the surrounding volume and provides 4 to 6 orders of magnitude higher ablation rates than the ion beam technique. In this work, a femtosecond laser was used to prepare wood samples from spruce for mechanical testing at the micrometre level. After optimization of the different laser parameters, tensile and compressive specimens were produced from microtomed radial-tangential and longitudinal-tangential sections. Additionally, laser-processed samples were exposed to an electron beam prior to testing to study possible beam damage. The specimens originating from these different preparation conditions were mechanically tested. Advantages and limitations of the femtosecond laser preparation technique and the deformation and fracture behaviour of the samples are discussed. The results prove that femtosecond laser processing is a fast and precise preparation technique, which enables the fabrication of pristine biological samples with dimensions at the microscale. PMID:28970867
NASA Astrophysics Data System (ADS)
Jakob, Severin; Pfeifenberger, Manuel J.; Hohenwarter, Anton; Pippan, Reinhard
2017-12-01
The standard preparation technique for micro-sized samples is focused ion beam milling, most frequently using Ga+ ions. The main drawbacks are the required processing time and the possibility and risks of ion implantation. In contrast, ultrashort pulsed laser ablation can process any type of material with ideally negligible damage to the surrounding volume and provides 4 to 6 orders of magnitude higher ablation rates than the ion beam technique. In this work, a femtosecond laser was used to prepare wood samples from spruce for mechanical testing at the micrometre level. After optimization of the different laser parameters, tensile and compressive specimens were produced from microtomed radial-tangential and longitudinal-tangential sections. Additionally, laser-processed samples were exposed to an electron beam prior to testing to study possible beam damage. The specimens originating from these different preparation conditions were mechanically tested. Advantages and limitations of the femtosecond laser preparation technique and the deformation and fracture behaviour of the samples are discussed. The results prove that femtosecond laser processing is a fast and precise preparation technique, which enables the fabrication of pristine biological samples with dimensions at the microscale.
Standardized cell samples for midIR technology development
NASA Astrophysics Data System (ADS)
Kastl, Lena; Rommel, Christina E.; Kemper, Björn; Schnekenburger, Jürgen
2015-03-01
The application of midIR spectroscopy towards human cell and tissue samples is impaired by the need for technical solutions and lacking sample standards for technology development. We here present the standardization of stable test samples for the continuous development and testing of novel optical system components. We have selected cell lines representing the major cellular skin constituents keratinocytes and fibroblasts (NIH-3T3, HaCaT). In addition, two skin cancer cell types (A-375 and SK-MEL-28 cells) were analyzed. Cells were seeded on CaF2 substrates and measured dried and under aqueous medium as well as fixated and unfixated. Several independent cell preparations were analyzed with an FTIR spectrometer in the wave number range from 1000 - 4000 cm-1. The obtained data demonstrate that fixed and dehydrated cells on CaF2 can be stored in pure ethanol for several weeks without significant losses in quality of the spectral properties. The established protocol of cell seeding on CaF2 substrates, chemical fixation, dehydration, storage under ethanol and air-drying is suitable for the production of reliable midIR standards. The retrieved spectra demonstrate that fixed cells on CaF2 can be prepared reproducibly; with stable midIR spectral properties over several weeks and properties mimicking reliable unfixed cells. Moreover, the fixated samples on CaF2 show clear differences in the cell type specific spectra that can be identified by principle component analysis. In summary, the standardized cell culture samples on CaF2 substrates are suitable for the development of a midIR device and the optimization of the specific midIR spectra.
Workshop on standards in biomass for energy and chemicals: proceedings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Milne, T.A.
1984-11-01
In the course of reviewing standards literature, visiting prominent laboratories and research groups, attending biomass meetings and corresponding widely, a whole set of standards needs was identified, the most prominent of which were: biomass standard reference materials, research materials and sample banks; special collections of microorganisms, clonal material, algae, etc.; standard methods of characterization of substrates and biomass fuels; standard tests and methods for the conversion and end-use of biomass; standard protocols for the description, harvesting, preparation, storage, and measurement of productivity of biomass materials in the energy context; glossaries of terms; development of special tests for assay of enzymaticmore » activity and related processes. There was also a recognition of the need for government, professional and industry support of concensus standards development and the dissemination of information on standards. Some 45 biomass researchers and managers met with key NBS staff to identify and prioritize standards needs. This was done through three working panels: the Panel on Standard Reference Materials (SRM's), Research Materials (RM's), and Sample Banks; the Panel on Production and Characterization; and the Panel on Tests and Methods for Conversion and End Use. This report gives a summary of the action items in standards development recommended unanimously by the workshop attendees. The proceedings of the workshop, and an appendix, contain an extensive written record of the findings of the workshop panelists and others regarding presently existing standards and standards issues and needs. Separate abstracts have been prepared for selected papers for inclusion in the Energy Database.« less
ERIC Educational Resources Information Center
Arnold, Randy J.; Arndt, Brett; Blaser, Emilia; Blosser, Chris; Caulton, Dana; Chung, Won Sog; Fiorenza, Garrett; Heath, Wyatt; Jacobs, Alex; Kahng, Eunice; Koh, Eun; Le, Thao; Mandla, Kyle; McCory, Chelsey; Newman, Laura; Pithadia, Amit; Reckelhoff, Anna; Rheinhardt, Joseph; Skljarevski, Sonja; Stuart, Jordyn; Taylor, Cassie; Thomas, Scott; Tse, Kyle; Wall, Rachel; Warkentien, Chad
2011-01-01
A multivitamin tablet and liquid are analyzed for the elements calcium, magnesium, iron, zinc, copper, and manganese using atomic absorption spectrometry. Linear calibration and standard addition are used for all elements except calcium, allowing for an estimate of the matrix effects encountered for this complex sample. Sample preparation using…
The method is for extracting an indoor and outdoor air sample consisting of a quartz fiber filter and an XAD-2 cartridge for analysis of neutral persistent organic pollutants. It covers the extraction and concentration of samples that are to be analyzed by gas chromatography/mass...
The purpose of this SOP is to describe the procedures for extracting and preparing a sill surface wipe sample for gas chromatography/mass spectrometry (GC/MS) analysis of pesticides. This procedure is also used for the pre-shipment analysis of sill wipe samples for materials sui...
Guide for preparing active solar heating systems operation and maintenance manuals
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1991-01-01
This book presents a systematic and standardized approach to the preparation of operation and maintenance manuals for active solar heating systems. Provides an industry consensus of the best operating and maintenance procedures for large commercial-scale solar service water and space heating systems. A sample O M manual is included. 3-ring binder included.
Lorenz, Matthew A.; Burant, Charles F.; Kennedy, Robert T.
2011-01-01
A simple, fast, and reproducible sample preparation procedure was developed for relative quantification of metabolites in adherent mammalian cells using the clonal β-cell line INS-1 as a model sample. The method was developed by evaluating the effect of different sample preparation procedures on high performance liquid chromatography- mass spectrometry quantification of 27 metabolites involved in glycolysis and the tricarboxylic acid cycle on a directed basis as well as for all detectable chromatographic features on an undirected basis. We demonstrate that a rapid water rinse step prior to quenching of metabolism reduces components that suppress electrospray ionization thereby increasing signal for 26 of 27 targeted metabolites and increasing total number of detected features from 237 to 452 with no detectable change of metabolite content. A novel quenching technique is employed which involves addition of liquid nitrogen directly to the culture dish and allows for samples to be stored at −80 °C for at least 7 d before extraction. Separation of quenching and extraction steps provides the benefit of increased experimental convenience and sample stability while maintaining metabolite content similar to techniques that employ simultaneous quenching and extraction with cold organic solvent. The extraction solvent 9:1 methanol: chloroform was found to provide superior performance over acetonitrile, ethanol, and methanol with respect to metabolite recovery and extract stability. Maximal recovery was achieved using a single rapid (~1 min) extraction step. The utility of this rapid preparation method (~5 min) was demonstrated through precise metabolite measurements (11% average relative standard deviation without internal standards) associated with step changes in glucose concentration that evoke insulin secretion in the clonal β-cell line INS-1. PMID:21456517
Kitagawa, Koichi; Shigemura, Katsumi; Onuma, Ken-Ichiro; Nishida, Masako; Fujiwara, Mayu; Kobayashi, Saori; Yamasaki, Mika; Nakamura, Tatsuya; Yamamichi, Fukashi; Shirakawa, Toshiro; Tokimatsu, Issei; Fujisawa, Masato
2018-03-01
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) contributes to rapid identification of pathogens in the clinic but has not yet performed especially well for Gram-positive cocci (GPC) causing complicated urinary tract infection (UTI). The goal of this study was to investigate the possible clinical use of MALDI-TOF MS as a rapid method for bacterial identification directly from urine in complicated UTI. MALDI-TOF MS was applied to urine samples gathered from 142 suspected complicated UTI patients in 2015-2017. We modified the standard procedure (Method 1) for sample preparation by adding an initial 10 minutes of ultrasonication followed by centrifugation at 500 g for 1 minutes to remove debris such as epithelial cells and leukocytes from the urine (Method 2). In 133 urine culture-positive bacteria, the rate of corresponded with urine culture in GPC by MALDI-TOF MS in urine with standard sample preparation (Method 1) was 16.7%, but the modified sample preparation (Method 2) significantly improved that rate to 52.2% (P=.045). Method 2 also improved the identification accuracy for Gram-negative rods (GNR) from 77.1% to 94.2% (P=.022). The modified Method 2 significantly improved the average MALDI score from 1.408±0.153 to 2.166±0.045 (P=.000) for GPC and slightly improved the score from 2.107±0.061 to 2.164±0.037 for GNR. The modified sample preparation for MALDI-TOF MS can improve identification accuracy for complicated UTI causative bacteria. This simple modification offers a rapid and accurate routine diagnosis for UTI, and may possibly be a substitute for urine cultures. © 2017 Wiley Periodicals, Inc.
Li, Chen; Habler, Gerlinde; Baldwin, Lisa C; Abart, Rainer
2018-01-01
Focused ion beam (FIB) sample preparation technique in plan-view geometry allows direct correlations of the atomic structure study via transmission electron microscopy with micrometer-scale property measurements. However, one main technical difficulty is that a large amount of material must be removed underneath the specimen. Furthermore, directly monitoring the milling process is difficult unless very large material volumes surrounding the TEM specimen site are removed. In this paper, a new cutting geometry is introduced for FIB lift-out sample preparation with plan-view geometry. Firstly, an "isolated" cuboid shaped specimen is cut out, leaving a "bridge" connecting it with the bulk material. Subsequently the two long sides of the "isolated" cuboid are wedged, forming a triangular prism shape. A micromanipulator needle is used for in-situ transfer of the specimen to a FIB TEM grid, which has been mounted parallel with the specimen surface using a simple custom-made sample slit. Finally, the grid is transferred to the standard FIB grid holder for final thinning with standard procedures. This new cutting geometry provides clear viewing angles for monitoring the milling process, which solves the difficulty of judging whether the specimen has been entirely detached from the bulk material, with the least possible damage to the surrounding materials. With an improved success rate and efficiency, this plan-view FIB lift-out specimen preparation technique should have a wide application for material science. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoogheem, T.J.; Woods, L.A.
The Monsanto Analytical Testing (MAT) program was devised and implemented in order to provide analytical standards to Monsanto manufacturing plants involved in the self-monitoring of plant discharges as required by National Pollutant Discharge Elimination System (NPDES) permit conditions. Standards are prepared and supplied at concentration levels normally observed at each individual plant. These levels were established by canvassing all Monsanto plants having NPDES permits and by determining which analyses and concentrations were most appropriate. Standards are prepared by Monsanto's analyses and concentrations were most appropriate. Standards are prepared by Monsanto's Environmental Sciences Center (ESC) using Environmental Protection Agency (EPA) methods.more » Eleven standards are currently available, each in three concentrations. Standards are issued quarterly in a company internal round-robin program or on a per request basis or both. Since initiation of the MAT program in 1981, the internal round-robin program has become an integral part of Monsanto's overall Good Laboratory Practices (GLP) program. Overall, results have shown that the company's plant analytical personnel can accurately analyze and report standard test samples. More importantly, such personnel have gained increased confidence in their ability to report accurate values for compounds regulated in their respective plant NPDES permits. 3 references, 3 tables.« less
Medvedovici, Andrei; Albu, Florin; Sora, Iuliana Daniela; Udrescu, Stefan; Galaon, Toma; David, Victor
2009-10-01
A sensitive method for determination of free captopril as monobromobimane derivative in plasma samples is discussed. The internal standard (IS) was 5-methoxy-1H-benzimidazole-2-thiol. Derivatization with monobromobimane immediately after blood collection and plasma preparation prevents oxidation of captopril to the corresponding disulfide compound and enhances the ionization yield. Consequently, derivatization enhances sample stability and detection sensitivity. Addition of the internal standard was made immediately after plasma preparation. The internal standard was also derivatized by monobromobimane, as it contains a thiol functional group. Preparation of plasma samples containing captopril and IS derivatives was based upon protein precipitation through addition of acetonitrile, in a volumetric ratio 1:2. The reversed-phase liquid chromatographic separation was achieved on a rapid resolution cartridge Zorbax SB-C(18), monitored through positive electrospray ionization and tandem MS detection using the multiple-reaction monitoring mode. Transitions were 408-362 amu for the captopril derivative and 371-260 amu for the internal standard derivative. The kinetics of captopril oxidation to the corresponding disulfide compound in plasma matrix was also studied using the proposed method. A linear log-log calibration was obtained over the concentration interval 2.5-750 ng/mL. A low limit of quantitation in the 2.5 ng/mL range was obtained. The analytical method was fully validated and successfully applied in a three-way, three-period, single-dose (50 mg), block-randomized bioequivalence study for two pharmaceutical formulations (captopril LPH 25 and 50 mg) against the comparator Capoten 50 mg. Copyright (c) 2009 John Wiley & Sons, Ltd.
ERIC Educational Resources Information Center
Khan, Suhail Ahmed; Ayyub, Khan Farhat
2013-01-01
This paper focuses on the relationship between academic stress and socio-economic status among IX standard students. The research was carried out in Raipur City (Chhattisgarh) on a sample of 600 IX standard students of English and Hindi medium schools. Academic Stress was measured by Stress Inventory for School Students prepared by Seema Rani…
Stalder, J; Costanzo, A; Daas, A; Rautmann, G; Buchheit, K-H
2010-04-01
A reference standard calibrated in International Units (IU) is needed for the in vitro potency assay of hepatitis A vaccines prepared by formalin-inactivation of purified hepatitis A virus grown in cell cultures. Thus, a project was launched by the European Directorate for the Quality of Medicines & HealthCare (EDQM) to establish one or more non-adsorbed inactivated hepatitis A vaccine reference preparation(s) as working standard(s), calibrated against the 1st International Standard (IS), for the in vitro potency assay (ELISA) of all vaccines present on the European market. Four non-adsorbed liquid preparations of formalin-inactivated hepatitis A antigen with a known antigen content were obtained from 3 manufacturers as candidate Biological Reference Preparations (BRPs). Thirteen laboratories participated in the collaborative study. They were asked to use an in vitro ELISA method adapted from a commercially available kit for the detection of antibodies to hepatitis A virus. In-house validated assays were to be run in parallel, where available. Some participants also included commercially available hepatitis A vaccines in the assays, after appropriate desorption. During the collaborative study, several participants using the standard method were faced with problems with some of the most recent lots of the test kits. Due to these problems, the standard method did not perform satisfactorily and a high number of assays were invalid, whereas the in-house methods appeared to perform better. Despite this, the overall mean results of the valid assays using both methods were in agreement. Nonetheless, it was decided to base the assignment of the potency values on the in-house methods only. The results showed that all candidate BRPs were suitable for the intended purpose. However, based on availability of the material and on the results of end-product testing, 2 candidate reference preparations, Samples C and D, were selected. Both were from the same batch but filled on different days; no statistically significant difference in potency was observed. They were thus combined in 1 single batch. The candidate preparation (Sample C/D) was adopted at the June 2009 session of the European Pharmacopoeia (Ph. Eur.) Commission as the Ph. Eur. BRP batch 1 for hepatitis A vaccine (inactivated, non-adsorbed), with an assigned potency of 12 IU/ml for in vitro antigen content assays. Accelerated degradation studies have been initiated. The preliminary data show that the BRP is stable at the recommended storage temperature (< -50 degrees C). The BRP will be monitored at regular intervals throughout its lifetime.
DOT National Transportation Integrated Search
2013-02-01
Standard sample sets of cement and mortar formulations with known levels of Cl as well as concrete samples subject to Cl diffusion were all prepared for and analyzed with scanning electron microscopy (SEM) and electron microprobe (EPMA). Using x-ray ...
Formalin fixation and paraffin embedding (FFPE) is a cross-industry gold standard for preparing nonclinical and clinical samples for histopathological assessment which preserves tissue architecture and enables storage of tissue in archival banks. These archival banks are an untap...
Synthesis of amino-functionalized silica nanoparticles for preparation of new laboratory standards
NASA Astrophysics Data System (ADS)
Alvarez-Toral, Aitor; Fernández, Beatriz; Malherbe, Julien; Claverie, Fanny; Pecheyran, Christophe; Pereiro, Rosario
2017-12-01
Platinum group elements (PGEs) are particularly interesting analytes in different fields, including environmental samples as well as high cost materials that contain them, such as for example automotive catalysts. This type of solid samples could be analysed by laser ablation (LA) coupled to ICP-MS, which allow to significantly reducing the analysis time since the time-consuming processes for sample preparation are not required. There is a considerable demand of standards with high PGEs concentration for quantification purposes, which cannot be carried out easily using LA-ICP-MS because the available standards (i.e. NIST SRM 61 × series) do not have such analytes in the same concentration range. In this paper, a new strategy is proposed for the synthesis of homogeneous laboratory standards with Pt, Pd and Rh concentrations that range from 77 μg/g of Pd up to 2035 μg/g of Rh. The proposed strategy is based on the synthesis of monodisperse amino-functionalized amorphous silica nanoparticles, which can retain metal ions. In addition to Pt, Pd and Rh, three lanthanides were also added to the nanoparticles (La, Ce, Nd). Sturdy pressed pellets can be made from the resulting nanopowder without the use of any binder. Elemental composition of standards made of nanoparticles was analysed by conventional nebulization ICP-MS and their homogeneity was successfully evaluated by LA-ICP-MS.
This standard operating procedure (SOP) describes a new, rapid, and relatively inexpensive way to remove a precise area of paint from the substrate of building structures in preparation for quantitative analysis. This method has been applied successfully in the laboratory, as we...
Application of an ETV-ICP system for the determination of elements in human hair*1
NASA Astrophysics Data System (ADS)
Plantikow-Voβgätter, F.; Denkhaus, E.
1996-01-01
When determining element contents in hair samples without sample digestion it is necessary to analyze large sample volumes in order to minimize problems of inhomogeneity of biological sample materials. Therefore an electrothermal vaporization system (ETV) is used for solid sample introduction into an inductively coupled plasma (ICP) for the determination of matrix and trace elements in hair. This paper concentrates on the instrumental aspects without time consuming sample preparation. The results obtained for optimization tests, ETV operating parameters and ICP operating parameters, are shown and discussed. Standard additions are used for calibration for the determination of Zn, Mg, and Mn in human hair. Studies including reproducibility and detection limits for chosen elements have been carried out on certified reference materials (CRMs). The determination of reproducibility (relative standard deviation (RSD) of n = 10) and detection limits (DLs) of Zn (RSD < 8.5%, DL < 0.8 μ g -1), Mn (RSD < 14.1%, DL < 0.3 μ g -1), and Mg (RSD < 7.4%, DL < 6.6 μ g -1) are satisfactory. The concentration values found show good agreement with the corresponding certified values. Further sample preparation steps, including hair sampling, washing procedure and homogenization for hair, relating to measurements of real hair samples are described.
García, I; Echeberria, J; Kakazei, G N; Golub, V O; Saliuk, O Y; Ilyn, M; Guslienko, K Y; González, J M
2012-09-01
Nanoparticles of Co10Cu90 alloy have been prepared by sonochemical wet method. According to transmission electron microscopy, bimetallic particles with typical diameter of 50-100 nm consisting of nanocrystallites with average diameter of 15-20 nm were obtained. The samples were annealed at 300 degrees C and 450 degrees C. Zero field cooled and field cooled temperature dependences of magnetization in the temperature range of 5-400 K at 50 Oe, as well as magnetization hysteresis loops at 15, 100 and 305 K were measured by vibrating sample magnetometry. Presence of antiferromagnetic phase, most probably of the oxide Co3O4, was observed in as-prepared sample. The lowest coercivity was found for the CoCu sample annealed at-300 degrees C, whereas for as prepared sample and the one annealed at 450 degrees C it was significantly higher. The samples were additionally probed by continuous wave ferromagnetic resonance at room, temperature using a standard X-band electron spin resonance spectrometer. A good correspondence between evolution of the coercivity and the microwave resonance fields with annealing temperature was observed.
Standardized protocols for quality control of MRM-based plasma proteomic workflows.
Percy, Andrew J; Chambers, Andrew G; Smith, Derek S; Borchers, Christoph H
2013-01-04
Mass spectrometry (MS)-based proteomics is rapidly emerging as a viable technology for the identification and quantitation of biological samples, such as human plasma--the most complex yet commonly employed biofluid in clinical analyses. The transition from a qualitative to quantitative science is required if proteomics is going to successfully make the transition to a clinically useful technique. MS, however, has been criticized for a lack of reproducibility and interlaboratory transferability. Currently, the MS and plasma proteomics communities lack standardized protocols and reagents to ensure that high-quality quantitative data can be accurately and precisely reproduced by laboratories across the world using different MS technologies. Toward addressing this issue, we have developed standard protocols for multiple reaction monitoring (MRM)-based assays with customized isotopically labeled internal standards for quality control of the sample preparation workflow and the MS platform in quantitative plasma proteomic analyses. The development of reference standards and their application to a single MS platform is discussed herein, along with the results from intralaboratory tests. The tests highlighted the importance of the reference standards in assessing the efficiency and reproducibility of the entire bottom-up proteomic workflow and revealed errors related to the sample preparation and performance quality and deficits of the MS and LC systems. Such evaluations are necessary if MRM-based quantitative plasma proteomics is to be used in verifying and validating putative disease biomarkers across different research laboratories and eventually in clinical laboratories.
AL-DWAIRI, Ziad Nawaf; AL-HIYASAT, Ahmad Saleh; ABOUD, Haitham
2011-01-01
Objectives To investigate if general dental practitioners (GDPs) in private practice in Jordan follow universal guidelines for preparation of anterior teeth for resin bonded all-ceramic crowns (RBCs). Material and Methods A sample (n=100) of laboratory models containing 208 tooth preparations for IPS Empress and In Ceram, featuring work from different GDPs, was obtained from 8 commercial dental laboratories. Aspects of preparations were quantified and compared with accepted criteria defined following a review of the literature and recommendations of the manufactures' guidelines. Results Subgingival margins on the buccal aspect were noticed in 36% of the preparations, 54% demonstrated overpreparation with a tendency to overprepare the teeth on the mesiodistal plane more than buccolingual plane. Twenty percent of samples presented a shoulder finish line while a chamfer margin design was noticed in 39%. Twenty-nine percent and 12% of samples had either a feathered or no clear margin design respectively. Incisal under preparation was observed in 18% of dies of each type. Only 17% of all preparations were found to follow the recommended anatomical labial preparations while 29% of the RBC preparations were found to have the recommended axial convergence angle. In total, 43% of preparations were found to have the recommended depth of the finish line. Conclusions It was found that relevant guidelines for RBC preparations were not being fully adhered to in private practice in Jordan. PMID:21710098
Optimization for Peptide Sample Preparation for Urine Peptidomics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sigdel, Tara K.; Nicora, Carrie D.; Hsieh, Szu-Chuan
2014-02-25
Analysis of native or endogenous peptides in biofluids can provide valuable insights into disease mechanisms. Furthermore, the detected peptides may also have utility as potential biomarkers for non-invasive monitoring of human diseases. The non-invasive nature of urine collection and the abundance of peptides in the urine makes analysis by high-throughput ‘peptidomics’ methods , an attractive approach for investigating the pathogenesis of renal disease. However, urine peptidomics methodologies can be problematic with regards to difficulties associated with sample preparation. The urine matrix can provide significant background interference in making the analytical measurements that it hampers both the identification of peptides andmore » the depth of the peptidomics read when utilizing LC-MS based peptidome analysis. We report on a novel adaptation of the standard solid phase extraction (SPE) method to a modified SPE (mSPE) approach for improved peptide yield and analysis sensitivity with LC-MS based peptidomics in terms of time, cost, clogging of the LC-MS column, peptide yield, peptide quality, and number of peptides identified by each method. Expense and time requirements were comparable for both SPE and mSPE, but more interfering contaminants from the urine matrix were evident in the SPE preparations (e.g., clogging of the LC-MS columns, yellowish background coloration of prepared samples due to retained urobilin, lower peptide yields) when compared to the mSPE method. When we compared data from technical replicates of 4 runs, the mSPE method provided significantly improved efficiencies for the preparation of samples from urine (e.g., mSPE peptide identification 82% versus 18% with SPE; p = 8.92E-05). Additionally, peptide identifications, when applying the mSPE method, highlighted the biology of differential activation of urine peptidases during acute renal transplant rejection with distinct laddering of specific peptides, which was obscured for most proteins when utilizing the conventional SPE method. In conclusion, the mSPE method was found to be superior to the conventional, standard SPE method for urine peptide sample preparation when applying LC-MS peptidomics analysis due to the optimized sample clean up that provided improved experimental inference from the confidently identified peptides.« less
A new standard of visual data representation for imaging mass spectrometry.
O'Rourke, Matthew B; Padula, Matthew P
2017-03-01
MALDI imaging MS (IMS) is principally used for cancer diagnostics. In our own experience with publishing IMS data, we have been requested to modify our protocols with respect to the areas of the tissue that are imaged in order to comply with the wider literature. In light of this, we have determined that current methodologies lack effective controls and can potentially introduce bias by only imaging specific areas of the targeted tissue EXPERIMENTAL DESIGN: A previously imaged sample was selected and then cropped in different ways to show the potential effect of only imaging targeted areas. By using a model sample, we were able to effectively show how selective imaging of samples can misinterpret tissue features and by changing the areas that are acquired, according to our new standard, an effective internal control can be introduced. Current IMS sampling convention relies on the assumption that sample preparation has been performed correctly. This prevents users from checking whether molecules have moved beyond borders of the tissue due to delocalization and consequentially products of improper sample preparation could be interpreted as biological features that are of critical importance when encountered in a visual diagnostic. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Field, Christopher R.; Lubrano, Adam; Woytowitz, Morgan; Giordano, Braden C.; Rose-Pehrsson, Susan L.
2014-01-01
The direct liquid deposition of solution standards onto sorbent-filled thermal desorption tubes is used for the quantitative analysis of trace explosive vapor samples. The direct liquid deposition method yields a higher fidelity between the analysis of vapor samples and the analysis of solution standards than using separate injection methods for vapors and solutions, i.e., samples collected on vapor collection tubes and standards prepared in solution vials. Additionally, the method can account for instrumentation losses, which makes it ideal for minimizing variability and quantitative trace chemical detection. Gas chromatography with an electron capture detector is an instrumentation configuration sensitive to nitro-energetics, such as TNT and RDX, due to their relatively high electron affinity. However, vapor quantitation of these compounds is difficult without viable vapor standards. Thus, we eliminate the requirement for vapor standards by combining the sensitivity of the instrumentation with a direct liquid deposition protocol to analyze trace explosive vapor samples. PMID:25145416
Field, Christopher R; Lubrano, Adam; Woytowitz, Morgan; Giordano, Braden C; Rose-Pehrsson, Susan L
2014-07-25
The direct liquid deposition of solution standards onto sorbent-filled thermal desorption tubes is used for the quantitative analysis of trace explosive vapor samples. The direct liquid deposition method yields a higher fidelity between the analysis of vapor samples and the analysis of solution standards than using separate injection methods for vapors and solutions, i.e., samples collected on vapor collection tubes and standards prepared in solution vials. Additionally, the method can account for instrumentation losses, which makes it ideal for minimizing variability and quantitative trace chemical detection. Gas chromatography with an electron capture detector is an instrumentation configuration sensitive to nitro-energetics, such as TNT and RDX, due to their relatively high electron affinity. However, vapor quantitation of these compounds is difficult without viable vapor standards. Thus, we eliminate the requirement for vapor standards by combining the sensitivity of the instrumentation with a direct liquid deposition protocol to analyze trace explosive vapor samples.
Eberl, D.D.
2003-01-01
RockJock is a computer program that determines quantitative mineralogy in powdered samples by comparing the integrated X-ray diffraction (XRD) intensities of individual minerals in complex mixtures to the intensities of an internal standard. Analysis without an internal standard (standardless analysis) also is an option. This manual discusses how to prepare and X-ray samples and mineral standards for these types of analyses and describes the operation of the program. Carefully weighed samples containing an internal standard (zincite) are ground in a McCrone mill. Randomly oriented preparations then are X-rayed, and the X-ray data are entered into the RockJock program. Minerals likely to be present in the sample are chosen from a list of standards, and the calculation is begun. The program then automatically fits the sum of stored XRD patterns of pure standard minerals (the calculated pattern) to the measured pattern by varying the fraction of each mineral standard pattern, using the Solver function in Microsoft Excel to minimize a degree of fit parameter between the calculated and measured pattern. The calculation analyzes the pattern (usually 20 to 65 degrees two-theta) to find integrated intensities for the minerals. Integrated intensities for each mineral then are determined from the proportion of each mineral standard pattern required to give the best fit. These integrated intensities then are compared to the integrated intensity of the internal standard, and the weight percentages of the minerals are calculated. The results are presented as a list of minerals with their corresponding weight percent. To some extent, the quality of the analysis can be checked because each mineral is analyzed independently, and, therefore, the sum of the analysis should approach 100 percent. Also, the method has been shown to give good results with artificial mixtures. The program is easy to use, but does require an understanding of mineralogy, of X-ray diffraction practice, and an elementary knowledge of the Excel program.
Hondrogiannis, Ellen M; Ehrlinger, Erin; Poplaski, Alyssa; Lisle, Meredith
2013-11-27
A total of 11 elements found in 25 vanilla samples from Uganda, Madagascar, Indonesia, and Papua New Guinea were measured by laser ablation-inductively coupled plasma-time-of-flight-mass spectrometry (LA-ICP-TOF-MS) for the purpose of collecting data that could be used to discriminate among the origins. Pellets were prepared of the samples, and elemental concentrations were obtained on the basis of external calibration curves created using five National Institute of Standards and Technology (NIST) standards and one Chinese standard with (13)C internal standardization. These curves were validated using NIST 1573a (tomato leaves) as a check standard. Discriminant analysis was used to successfully classify the vanilla samples by their origin. Our method illustrates the feasibility of using LA-ICP-TOF-MS with an external calibration curve for high-throughput screening of spice screening analysis.
NASA Astrophysics Data System (ADS)
Stosnach, Hagen; Mages, Margarete
2009-04-01
In clinical service laboratories, one of the most common analytical tasks with regard to inorganic traces is the determination of the nutrition-relevant elements Fe, Cu, Zn, and Se. Because of the high numbers of samples and the commercial character of these analyses, a time-consuming sample preparation must be avoided. In this presentation, the results of total reflection X-ray fluorescence measurements with a low-power system and different sample preparation procedures are compared with those derived from analysis with common methods like Atomic Absorption Spectroscopy (AAS) and Inductively Coupled Plasma Mass Spectroscopy (ICP-MS). The results of these investigations indicate that the optimal total reflection X-ray fluorescence analysis of the nutrition-relevant elements Fe, Cu, Zn, and Se can be performed by preparing whole blood and serum samples after dilution with ultrapure water and transferring 10 μl of internally standardized sample to an unsiliconized quartz glass sample carrier with subsequent drying in a laboratory oven. Suitable measurement time was found to be 600 s. The enhanced sample preparation by means of microwave or open digestion, in parts combined with cold plasma ashing, led to an improvement of detection limits by a factor of 2 for serum samples while for whole blood samples an improvement was only observed for samples prepared by means of microwave digestion. As the matrix elements P, S, Cl, and for whole blood Fe have a major influence on the detection limits, most probably a further enhancement of analytical quality requires the removal of the organic matrix. However, for the routine analysis of the nutrition-relevant elements, the dilution preparation was found to be sufficient.
Kos, Gregor; Lohninger, Hans; Mizaikoff, Boris; Krska, Rudolf
2007-07-01
A sample preparation procedure for the determination of deoxynivalenol (DON) using attenuated total reflection mid-infrared spectroscopy is presented. Repeatable spectra were obtained from samples featuring a narrow particle size distribution. Samples were ground with a centrifugal mill and analysed with an analytical sieve shaker. Particle sizes of <100, 100-250, 250-500, 500-710 and 710-1000 microm were obtained. Repeatability, classification and quantification abilities for DON were compared with non-sieved samples. The 100-250 microm fraction showed the best repeatability. The relative standard deviation of spectral measurements improved from 20 to 4.4% and 100% of sieved samples were correctly classified compared with 79% of non-sieved samples. The DON level in analysed fractions was a good estimate of overall toxin content.
The purpose of this SOP is to describe procedures for preparing calibration curve solutions used for gas chromatography/mass spectrometry (GC/MS) analysis of chlorpyrifos, diazinon, malathion, DDT, DDE, DDD, a-chlordane, and g-chlordane in dust, soil, air, and handwipe sample ext...
Tvedt, Tor Henrik Anderson; Rye, Kristin Paulsen; Reikvam, Håkon; Brenner, Annette K; Bruserud, Øystein
2015-03-01
Cytokines, soluble adhesion molecules and metalloproteinases can be detected in human serum or plasma samples. Such systemic levels are widely used as biomarkers in epidemiological and clinical studies. We prepared serum samples and three types of plasma samples (EDTA, heparin, citric acid) from 20 healthy individuals. The levels of 31 cytokines, four soluble adhesion molecules and eight matrix metalloproteinases were analyzed by Luminex technology. Most mediators showed detectable levels in both plasma and serum. Several mediators that can be released by platelets showed increased serum levels, especially CCL5 and CD40L, but for the other mediators the serum levels did not correlate with peripheral blood platelet counts and for these last mediators serum and plasma levels often showed strong correlations. The use of bivalirudin for anticoagulation significantly increased and citric acid combined with platelet inhibitors (ticagrelor, acetylsalicylic acid plus prostaglandin E2) did not alter plasma levels of platelet-store mediators compared with citric acid alone. The impact of sample preparation differed between mediators; for many mediators strong correlations were seen between serum and plasma levels even when absolute levels differed. Soluble adhesion molecule levels showed only minor differences between samples. Unsupervised hierarchical clustering suggested that the effect of sampling/preparation was strongest for serum and heparin plasma samples. Careful standardization of sample preparation is usually necessary when analyzing systemic mediator levels, and differences caused by sample preparation should be considered as a possible explanation if studies show conflicting results. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Kim, Hyun Jung; Choi, Sang H.; Bae, Hyung-Bin; Lee, Tae Woo
2012-01-01
The National Aeronautics and Space Administration-invented X-ray diffraction (XRD) methods, including the total defect density measurement method and the spatial wafer mapping method, have confirmed super hetero epitaxy growth for rhombohedral single crystalline silicon germanium (Si1-xGex) on a c-plane sapphire substrate. However, the XRD method cannot observe the surface morphology or roughness because of the method s limited resolution. Therefore the authors used transmission electron microscopy (TEM) with samples prepared in two ways, the focused ion beam (FIB) method and the tripod method to study the structure between Si1-xGex and sapphire substrate and Si1?xGex itself. The sample preparation for TEM should be as fast as possible so that the sample should contain few or no artifacts induced by the preparation. The standard sample preparation method of mechanical polishing often requires a relatively long ion milling time (several hours), which increases the probability of inducing defects into the sample. The TEM sampling of the Si1-xGex on sapphire is also difficult because of the sapphire s high hardness and mechanical instability. The FIB method and the tripod method eliminate both problems when performing a cross-section TEM sampling of Si1-xGex on c-plane sapphire, which shows the surface morphology, the interface between film and substrate, and the crystal structure of the film. This paper explains the FIB sampling method and the tripod sampling method, and why sampling Si1-xGex, on a sapphire substrate with TEM, is necessary.
Wadhwa, Meenu; Bird, Chris; Dougall, Thomas; Rigsby, Peter; Bristow, Adrian; Thorpe, Robin
2015-01-01
We assessed the feasibility of developing a suitable international reference standard for determination of in vitro biological activity of human sequence recombinant PEG-G-CSF products with a 20 kD linear PEG linked to the N-terminal methionyl residue of G-CSF (INN Filgrastim), produced using a conjugation process and coupling chemistry similar to that employed for the lead PEGfilgrastim product. Based on initial data which showed that the current WHO 2nd international standard, IS for G-CSF (09/136) or alternatively, a PEG-G-CSF standard with a unitage traceable to the G-CSF IS may potentially serve as the IS for PEG-G-CSF products, two candidate preparations of PEG-G-CSF were formulated and lyophilized at NIBSC. These preparations were tested by 23 laboratories using in vitro bioassays in a multi-centre collaborative study. Results indicated that on the basis of parallelism, the current WHO 2nd IS for G-CSF or any of the PEG-G-CSF samples could be used as the international standard for PEG-G-CSF preparations. However, because of the variability in potency estimates seen when PEG-G-CSF preparations were compared with the current WHO 2nd IS for G-CSF, a candidate PEG-G-CSF was suitable as the WHO IS. The preparation 12/188 was judged suitable to serve as the WHO IS based on in vitro biological activity data. Therefore, the preparation coded 12/188 was established by the WHO Expert Committee on Biological Standardization (ECBS) in 2013 as the WHO 1st IS for human PEGylated G-CSF with an assigned in vitro bioactivity of 10,000 IU per ampoule. PMID:25450254
Ascone, I; Sabatucci, A; Bubacco, L; Di Muro, P; Salvato, B
2000-01-01
In this study, solid samples of hemoglobin and hemocyanin have been prepared by embedding the proteins into a saccharose-based matrix. These materials have been developed specifically for specimens for X-ray absorption spectroscopy (XAS). The preservation of protein conformation and active site organization was tested, making comparisons between the solid and the corresponding liquid samples, using resonance Raman, infra red, fluorescence and XAS. The XAS spectra of irradiated solid and liquid samples were then compared, and the preservation of biological activity of the proteins during both preparation procedure and X-ray irradiation was assessed. In all cases, the measurements clearly demonstrate that protein solid samples are both structurally and functionally quite well preserved, much better than those in the liquid state. The saccharose matrix provides an excellent protection against X-ray damages, allowing for longer exposure to the X-ray beam. Moreover, the demonstrated long-term stability of samples permits their preparation and storage in optimal conditions, allowing for the repetition of data collection with the same sample in several experimental sessions. The very high protein concentration that can be reached results in a significantly better signal-to-noise ratio, particularly useful for high molecular weight proteins with a low metal-to-protein ratio. On the bases of the above-mentioned results, we propose the new method as a standard procedure for the preparation of biological samples to be used for XAS spectroscopy.
Nevada Applied Ecology Group procedures handbook for environmental transuranics
DOE Office of Scientific and Technical Information (OSTI.GOV)
White, M.G.; Dunaway, P.B.
The activities of the Nevada Applied Ecology Group (NAEG) integrated research studies of environmental plutonium and other transuranics at the Nevada Test Site have required many standardized field and laboratory procedures. These include sampling techniques, collection and preparation, radiochemical and wet chemistry analysis, data bank storage and reporting, and statistical considerations for environmental samples of soil, vegetation, resuspended particles, animals, and others. This document, printed in two volumes, includes most of the Nevada Applied Ecology Group standard procedures, with explanations as to the specific applications involved in the environmental studies. Where there is more than one document concerning a procedure,more » it has been included to indicate special studies or applications perhaps more complex than the routine standard sampling procedures utilized.« less
Nevada Applied Ecology Group procedures handbook for environmental transuranics
DOE Office of Scientific and Technical Information (OSTI.GOV)
White, M.G.; Dunaway, P.B.
The activities of the Nevada Applied Ecology Group (NAEG) integrated research studies of environmental plutonium and other transuranics at the Nevada Test Site have required many standardized field and laboratory procedures. These include sampling techniques, collection and preparation, radiochemical and wet chemistry analysis, data bank storage and reporting, and statistical considerations for environmental samples of soil, vegetation, resuspended particles, animals, and other biological material. This document, printed in two volumes, includes most of the Nevada Applied Ecology Group standard procedures, with explanations as to the specific applications involved in the environmental studies. Where there is more than one document concerningmore » a procedure, it has been included to indicate special studies or applications more complex than the routine standard sampling procedures utilized.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morales-Arteaga, Maria
This GUM WorkbenchTM propagation of uncertainty is for the coulometric measurement of the plutonium concentration in a Pu standard material (C126) supplied as individual aliquots that were prepared by mass. The C126 solution had been prepared and as aliquoted as standard material. Samples are aliquoted into glass vials and heated to dryness for distribution as dried nitrate. The individual plutonium aliquots were not separated chemically or otherwise purified prior to measurement by coulometry in the F/H Laboratory. Hydrogen peroxide was used for valence adjustment.
Choi, Sol Ji; Jung, Mun Yhung
2017-04-01
We have developed a simple and fast sample preparation technique in combination with a gas chromatography-tandem mass spectrometry (GC-MS/MS) for the quantification of 2-methylimidazole (2-MeI) and 4-methylimidazole (4-MeI) in colas and dark beers. Conventional sample preparation technique for GC-MS requires laborious and time-consuming steps consisting of sample concentration, pH adjustment, ion pair extraction, centrifugation, back-extraction, centrifugation, derivatization, and extraction. Our sample preparation technique consists of only 2 steps (in situ derivation and extraction) which requires less than 3 min. This method provided high linearity, low limit of detection and limit of quantification, high recovery, and high intra- and interday repeatability. It was found that internal standard method with diluted stable isotope (4-MeI-d 6 ) and 2-ethylimidazole (2-EI) could not correctly compensate the matrix effects. Thus, standard addition technique was used for the quantification of 2- and 4-MeI. The established method was successfully applied to colas and dark beers for the determination of 2-MeI and 4-MeI. The 4-MeI contents in colas and dark beers ranged from 8 to 319 μg/L and from trace to 417 μg/L, respectively. Small quantity (0 to 8 μg/L) of 2-MeI was found only in dark beers. The contents of 4-MeI (22 μg/L) in colas obtained from fast food restaurants were significantly lower than those (177 μg/L) in canned or bottled colas. © 2017 Institute of Food Technologists®.
This is a technical document that presents a detailed sample standard operating procedure (S.O.P.) for preparing plant nucleic acid samples for microarray analyses using commercial ¿chips¿ such as those sold by Affymetrix. It also presents the application of a commercially availa...
Community of Inquiry Method and Language Skills Acquisition: Empirical Evidence
ERIC Educational Resources Information Center
Preece, Abdul Shakhour Duncan
2015-01-01
The study investigates the effectiveness of community of inquiry method in preparing students to develop listening and speaking skills in a sample of junior secondary school students in Borno state, Nigeria. A sample of 100 students in standard classes was drawn in one secondary school in Maiduguri metropolis through stratified random sampling…
Dependence of precipitation of trace elements on pH in standard water
NASA Astrophysics Data System (ADS)
Verma, Shivcharan; Mohanty, Biraja P.; Singh, K. P.; Behera, B. R.; Kumar, Ashok
2018-04-01
The present work aimed to study the dependence of precipitation of trace elements on the pH of solution. A standard solution was prepared by using ultrapure deionized water (18.2 MΩ/cm) as the solvent and 11 water-soluble salts having different elements as solutes. Five samples of different pH values (2 acidic, 2 basic, and 1 neutral) were prepared from this standard solution. Sodium-diethyldithiocarbamate was used as the chelating agent to precipitate the metal ions present in these samples of different pH values. The targets were prepared by collecting these precipitates on mixed cellulose esters filter of 0.4 μm pore size by vacuum filtration. Elemental analysis of these targets was performed by particle-induced X-ray emission (PIXE) using 2.7 MeV protons from the single Dee variable energy cyclotron at Panjab University, Chandigarh, India. PIXE data were analyzed using GUPIXWIN software. For most of the elements, except Hg with oxidation state +2, such as Co, Ni, Zn, Ba, and Cd, a general trend of enhancement in precipitation was observed with the increase in pH. However, for other elements such as V, As, Mo, Ag, and Bi, which have oxidation state other than +2, no definite pattern was observed. Precipitation of Ba and As using this method was negligible at all five pH values. From these results, it can be concluded that the precipitation and recovery of elements depend strongly on the pH of the water sample.
This Standard Operating Procedure (SOP) describes a new, rapid, and relatively inexpensive one step procedure which grinds the paint samples removed from the substrate and simultaneously quantitatively extracts the Pb from the paint in only one step in preparation for quantitativ...
Parental Influence on Academic Achievement among the Primary School Students in Trinidad
ERIC Educational Resources Information Center
Johnson, Emmanuel Janagan; Descartes, Christine H.
2017-01-01
The present study examined the level of parental influence on academic achievement in primary school students who prepare for the National-level test at standard five (grade 6), Secondary Entrance Examinations in Trinidad. A sample of 128 students studying standard five from primary schools was randomly selected. The data were analysed using SPSS.…
Wele, Asmita A.; Pendse, Nikhil U.; Takle, Shrikant P.; Burase, Raghunath V.; Patil, Sanjay V.; Bhalerao, Supriya; Harsulkar, Abhay M.
2015-01-01
Introduction: Vasarishta built upon Mritasanjeevani Sura (MS) is a polyherbal hydro-alcoholic anti-asthmatic formulation which is administered in a dose of 1 ml instead of standard dose 40 ml, generally advocated for any “Asava–Arishta” in Ayurveda. Aim: The present study was aimed at finding out rationale for the peculiar distillation process to manufacture MS followed by Sthapana process to make Vasarishta. It was further aimed to find out difference in Vasarishta samples manufactured by purely fermentation process and the peculiar method mentioned above. Materials and Methods: Three batches of MS and subsequently three batches of Vasarishta were prepared. Basic standardization and development of standard operating procedure for the same were achieved by doing pH, percentage of alcohol and total reducing sugar, specific gravity on both MS and Vasarishta, during and after completion of process. Finally, MS and Vasarishta (built upon MS) made in laboratory were compared with marketed samples of MS and Vasarishta using gas chromatography. Results: The types of alcohols and volatile acids in MS and Vasarishta, prepared in laboratory, are similar but the proportions differ, which is taken as an indicator of process standardization. Values of furfural, ethyl acetate, and 1-butanol in lab samples are within permissible limits as against the values of the market samples. Conclusions: The textual process for the production of Vasarishta proved to produce organoleptically acceptable product which is virtually free of toxic compounds such as furfural. PMID:27313419
NASA Astrophysics Data System (ADS)
Lari, L.; Wright, I.; Boyes, E. D.
2015-10-01
A very simple tomography sample holder at minimal cost was developed in-house. The holder is based on a JEOL single tilt fast exchange sample holder where its exchangeable tip was modified to allow high angle degree tilt. The shape of the tip was designed to retain mechanical stability while minimising the lateral size of the tip. The sample can be mounted on as for a standard 3mm Cu grids as well as semi-circular grids from FIB sample preparation. Applications of the holder on different sample systems are shown.
Investigating a Drop-on-Demand Microdispenser for Standardized Sample Preparation
2011-09-01
including the printing of photodiodes , polymer and protein arrays , and in electronics manufacturing (4–7). These applications benefit from the wide...photograph of an array of microdroplets demonstrates a more even sample dispersion when sample is dispensed with a DOD microdispenser... threats encountered. A variety of techniques that offer temporary alternatives have been employed, including drop-and-dry (dropcasting) and spray
The purpose of this SOP is to describe the procedures for pre-cleaning filters and polyurethane foam (PUF) plug prior to air sampling with these media. The sampling media are used for sampling indoor air, outdoor air, and personal air. This procedure was followed to ensure consi...
Atmospheric Fluoroform (CHF3, HFC-23) at Cape Grim, Tasmania (1978-1995)
Oram, D. E. [University of East Anglia, Norwich, United Kingdom; Sturges, W. T. [University of East Anglia, Norwich, United Kingdom; Penkett, S. A. [University of East Anglia, Norwich, United Kingdom; McCulloch, A. [ICI Chemicals and Polymers, Ltd., Cheshire, United Kingdom; Fraser, P. J. [CRC for Southern Hemisphere Meteorology, Victoria, Australia
2000-10-01
The sampling and analytical methods are described more fully in Oram et al. (1998). In summary, air samples were taken from the archive of Cape Grim, Tasmania (41oS, 145oE) air samples collected from 1978 through 1995. Comparisons of CFC-11, CFC-12, CFC-113, CH3CCl3, and CH4 data between archive samples and corresponding in-situ samples for the same dates confirm that the archive samples are both representative and stable over time. Samples were analyzed by gas chromatography-mass spectrometry (GC-MS), using a KCl-passivated alumina PLOT column. Fluoroform was monitored on mass 69 (CF3+). The analytical precision (one standard deviation of the mean) for two or three replicate analyses was typically ± 1% of the mean measured value. The overall uncertainty of the observed data is ± 10%, taking into account uncertainties in the preparation of the primary standards, the purity of the fluoroform used to make the primary standards, as well as the analytical precision.
Brown, G.E.; McLain, B.J.
1994-01-01
The analysis of natural-water samples for antimony by automated-hydride atomic absorption spectrophotometry is described. Samples are prepared for analysis by addition of potassium and hydrochloric acid followed by an autoclave digestion. After the digestion, potassium iodide and sodium borohydride are added automatically. Antimony hydride (stibine) gas is generated, then swept into a heated quartz cell for determination of antimony by atomic absorption spectrophotometry. Precision and accuracy data are presented. Results obtained on standard reference water samples agree with means established by interlaboratory studies. Spike recoveries for actual samples range from 90 to 114 percent. Replicate analyses of water samples of varying matrices give relative standard deviations from 3 to 10 percent.
Nagy, M; Otremba, P; Krüger, C; Bergner-Greiner, S; Anders, P; Henske, B; Prinz, M; Roewer, L
2005-08-11
Automated procedures for forensic DNA analyses are essential not only for large-throughput sample preparation, but are also needed to avoid errors during routine sample preparation. The most critical stage in PCR-based forensic analysis is DNA isolation, which should yield as much highly purified DNA as possible. The extraction method used consists of pre-treatment of stains and samples, cell lysis using chaotropic reagents, binding of the DNA to silica-coated magnetic particles, followed by elution of the DNA. Our work focuses mainly on sample preparation, obtaining the maximum possible amount of biological material from forensic samples, and the following cell lysis, to create a simple standardized lysis protocol suitable for nearly all forensic material. After optimization and validation, the M-48 BioRobot((R)) workstation has been used for more than 20,000 routine lab samples. There has been no evidence of cross contamination. Resulting DNA from as small as three nuclear cells yield reliable complete STR amplification profiles. The DNA remains stable after 2 years of storage.
Sample weight and digestion temperature as critical factors in mercury determination in fish
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sadiq, M.; Zaidi, T.H.; Al-Mohana, H.
The concern about mercury (Hg) pollution of the marine environment started with the well publicized case of Minimata (Japan) where in the 1950s several persons died or became seriously ill after consuming fish or shellfish containing high levels of methylmercury. It is now accepted that Hg contaminated seafoods constitute a hazard to human health. To safeguard humans, accurate determination of Hg in marine biota is, therefore, very important. Two steps are involved in the determination of total Hg in biological materials: (a) decomposition of organic matrix (sample preparation), and (b) determination of Hg in aliquot samples. Although the procedures formore » determining Hg using the cold vapor technique are well established, sample preparation procedures have not been standardized. In general, samples of marine biota have been prepared by digesting different weights at different temperatures, by using mixtures of different chemicals and of varying quantities, and by digesting for variable durations. The objectives of the present paper were to evaluate the effects of sample weights and digestion temperatures on Hg determination in fish.« less
Quantitation of heat-shock proteins in clinical samples using mass spectrometry.
Kaur, Punit; Asea, Alexzander
2011-01-01
Mass spectrometry (MS) is a powerful analytical tool for proteomics research and drug and biomarker discovery. MS enables identification and quantification of known and unknown compounds by revealing their structural and chemical properties. Proper sample preparation for MS-based analysis is a critical step in the proteomics workflow because the quality and reproducibility of sample extraction and preparation for downstream analysis significantly impact the separation and identification capabilities of mass spectrometers. The highly expressed proteins represent potential biomarkers that could aid in diagnosis, therapy, or drug development. Because the proteome is so complex, there is no one standard method for preparing protein samples for MS analysis. Protocols differ depending on the type of sample, source, experiment, and method of analysis. Molecular chaperones play significant roles in almost all biological functions due to their capacity for detecting intracellular denatured/unfolded proteins, initiating refolding or denaturation of such malfolded protein sequences and more recently for their role in the extracellular milieu as chaperokines. In this chapter, we describe the latest techniques for quantitating the expression of molecular chaperones in human clinical samples.
Xue, Lu; Lin, Lin; Zhou, Wenbin; Chen, Wendong; Tang, Jun; Sun, Xiujie; Huang, Peiwu; Tian, Ruijun
2018-06-09
Plasma proteome profiling by LC-MS based proteomics has drawn great attention recently for biomarker discovery from blood liquid biopsy. Due to standard multi-step sample preparation could potentially cause plasma protein degradation and analysis variation, integrated proteomics sample preparation technologies became promising solution towards this end. Here, we developed a fully integrated proteomics sample preparation technology for both fast and deep plasma proteome profiling under its native pH. All the sample preparation steps, including protein digestion and two-dimensional fractionation by both mixed-mode ion exchange and high-pH reversed phase mechanism were integrated into one spintip device for the first time. The mixed-mode ion exchange beads design achieved the sample loading at neutral pH and protein digestion within 30 min. Potential sample loss and protein degradation by pH changing could be voided. 1 μL of plasma sample with depletion of high abundant proteins was processed by the developed technology with 12 equally distributed fractions and analyzed with 12 h of LC-MS gradient time, resulting in the identification of 862 proteins. The combination of the Mixed-mode-SISPROT and data-independent MS method achieved fast plasma proteome profiling in 2 h with high identification overlap and quantification precision for a proof-of-concept study of plasma samples from 5 healthy donors. We expect that the Mixed-mode-SISPROT become a generally applicable sample preparation technology for clinical oriented plasma proteome profiling. Copyright © 2018 Elsevier B.V. All rights reserved.
Peer, Cody J; Shakleya, Diaa M; Younis, Islam R; Kraner, James C; Callery, Patrick S
2007-10-01
A rapid mass spectrometric method was developed for the identification of fentanyl and its major hepatic metabolite norfentanyl in postmortem urine of six drug-overdose victims involving fentanyl use. To reduce matrix effects or ion suppression, sample preparation consisted of centrifugation and solid-phase extraction. Deuterium-labeled internal standards ((2)H(5)-fentanyl and (2)H(5)-norfentanyl) were used to compensate for instrument variation in signal, analyte recovery during sample preparation, and ion suppression. Structural information for fentanyl and norfentanyl were collected using mass spectrometry (MS) with electrospray ionization (ESI) operated in the positive ion mode. Fentanyl (m/z 337) was found in each of the six overdose cases by the appearance of the MS-MS daughter ion on both an ion trap and a triple-quadrupole MS resulting from the fragmentation pathway of fentanyl (m/z 337 --> 188). Norfentanyl was detected in all six cases by the appearance of the MH(+) ion, m/z 233, with a single-quadrupole MS and confirmed in an ion trap MS. Ion suppression, as determined by the comparison of ion intensities from spiked samples in water with postmortem urine from the cases, ranged from 18% to 98% in three ESI sources. The use of stable isotope-labeled internal standards obviates sample preparation because ratios of analyte/internal standard remain constant in the presence of extensive matrix effects. This MS method provided sufficient sensitivity and selectivity for the rapid identification of fentanyl and norfentanyl in urine at levels >/= 10 ng/mL without prior analyte resolution by chromatography and with a total analysis time of less than 1 h.
Zhao, Xinyan; Dong, Tao
2012-10-16
This study reports a quantitative nucleic acid sequence-based amplification (Q-NASBA) microfluidic platform composed of a membrane-based sampling module, a sample preparation cassette, and a 24-channel Q-NASBA chip for environmental investigations on aquatic microorganisms. This low-cost and highly efficient sampling module, having seamless connection with the subsequent steps of sample preparation and quantitative detection, is designed for the collection of microbial communities from aquatic environments. Eight kinds of commercial membrane filters are relevantly analyzed using Saccharomyces cerevisiae, Escherichia coli, and Staphylococcus aureus as model microorganisms. After the microorganisms are concentrated on the membrane filters, the retentate can be easily conserved in a transport medium (TM) buffer and sent to a remote laboratory. A Q-NASBA-oriented sample preparation cassette is originally designed to extract DNA/RNA molecules directly from the captured cells on the membranes. Sequentially, the extract is analyzed within Q-NASBA chips that are compatible with common microplate readers in laboratories. Particularly, a novel analytical algorithmic method is developed for simple but robust on-chip Q-NASBA assays. The reported multifunctional microfluidic system could detect a few microorganisms quantitatively and simultaneously. Further research should be conducted to simplify and standardize ecological investigations on aquatic environments.
Chang, Qiao-Ying; Pang, Guo-Fang; Fan, Chun-Lin; Chen, Hui; Yang, Fang; Li, Jie; Wen, Bi-Fang
2016-11-01
GC-MS, GC-tandem MS (MS/MS), and LC-MS/MS were used to mathematically define the degradation profiles of pesticide residues in two field trials. Nineteen pesticides were studied in the first field trial and 11 in the second. The results of the field trials demonstrated that the degradation profiles of pesticide residues in green tea can be described with power functions to successfully estimate the amount of time, following pesticide application, pesticide residues appearing in tea in concentrations at and/or above the maximum residue limit (MRL) decrease to concentrations below the MRL. Stability tests on green tea samples stored at room temperature were conducted to determine whether pesticide-incurred green tea samples prepared according to the method used in the field trials would be suitable for the preparation of reference standards for laboratory-proficiency testing trials. This paper reports the results of a GC-MS, GC-MS/MS, and LC-MS/MS study, as well as the suitability of the samples prepared under these conditions for use as pesticide reference standards in tea analysis.
Revision of ISO 15859 Aerospace Fluid Standards
NASA Technical Reports Server (NTRS)
Greene, Benjamin; McClure, Mark B.
2012-01-01
A detailed review of ISO 15859 "Space Systems - Fluid Characteristics, Sampling and Test Methods" was performed An approach to revising Parts 1-9 and 11-13 was developed and concurred by the NASA Technical Standards Program Office. The approach was to align them with the highest level source documents, and not to program-specific requirements. The updated documents were prepared and presented.
The purpose of this SOP is to describe procedures for extracting and preparing a dermal wipe sample for GC/MS analysis of pesticides. This procedure was followed to ensure consistent data retrieval during the Arizona NHEXAS project and the "Border" study. Keywords: dermal wipe;...
The purpose of this SOP is to describe the procedures for collecting surface wipe samples inside a home for analysis of either metals or pesticides. This procedure covers the preparation of the surface wipe material and field activities. This protocol was followed to ensure con...
Zhang, Shuai; Li, PeiPei; Yan, Zhongyong; Long, Ju; Zhang, Xiaojun
2017-03-01
An ultraperformance liquid chromatography-quadrupole time-of-flight high-resolution mass spectrometry method was developed and validated for the determination of nitrofurazone metabolites. Precolumn derivatization with 2,4-dinitrophenylhydrazine and p-dimethylaminobenzaldehyde as an internal standard was used successfully to determine the biomarker 5-nitro-2-furaldehyde. In negative electrospray ionization mode, the precise molecular weights of the derivatives were 320.0372 for the biomarker and 328.1060 for the internal standard (relative error 1.08 ppm). The matrix effect was evaluated and the analytical characteristics of the method and derivatization reaction conditions were validated. For comparison purposes, spiked samples were tested by both internal and external standard methods. The results show high precision can be obtained with p-dimethylaminobenzaldehyde as an internal standard for the identification and quantification of nitrofurazone metabolites in complex biological samples. Graphical Abstract A simplified preparation strategy for biological samples.
Evaluation on determination of iodine in coal by energy dispersive X-ray fluorescence
Wang, B.; Jackson, J.C.; Palmer, C.; Zheng, B.; Finkelman, R.B.
2005-01-01
A quick and inexpensive method of relative high iodine determination from coal samples was evaluated. Energy dispersive X-ray fluorescence (EDXRF) provided a detection limit of about 14 ppm (3 times of standard deviations of the blank sample), without any complex sample preparation. An analytical relative standard deviation of 16% was readily attainable for coal samples. Under optimum conditions, coal samples with iodine concentrations higher than 5 ppm can be determined using this EDXRF method. For the time being, due to the general iodine concentrations of coal samples lower than 5 ppm, except for some high iodine content coal, this method can not effectively been used for iodine determination. More work needed to meet the requirement of determination of iodine from coal samples for this method. Copyright ?? 2005 by The Geochemical Society of Japan.
Golubeva, Yelena G.; Smith, Roberta M.; Sternberg, Lawrence R.
2013-01-01
Laser microdissection is an invaluable tool in medical research that facilitates collecting specific cell populations for molecular analysis. Diversity of research targets (e.g., cancerous and precancerous lesions in clinical and animal research, cell pellets, rodent embryos, etc.) and varied scientific objectives, however, present challenges toward establishing standard laser microdissection protocols. Sample preparation is crucial for quality RNA, DNA and protein retrieval, where it often determines the feasibility of a laser microdissection project. The majority of microdissection studies in clinical and animal model research are conducted on frozen tissues containing native nucleic acids, unmodified by fixation. However, the variable morphological quality of frozen sections from tissues containing fat, collagen or delicate cell structures can limit or prevent successful harvest of the desired cell population via laser dissection. The CryoJane Tape-Transfer System®, a commercial device that improves cryosectioning outcomes on glass slides has been reported superior for slide preparation and isolation of high quality osteocyte RNA (frozen bone) during laser dissection. Considering the reported advantages of CryoJane for laser dissection on glass slides, we asked whether the system could also work with the plastic membrane slides used by UV laser based microdissection instruments, as these are better suited for collection of larger target areas. In an attempt to optimize laser microdissection slide preparation for tissues of different RNA stability and cryosectioning difficulty, we evaluated the CryoJane system for use with both glass (laser capture microdissection) and membrane (laser cutting microdissection) slides. We have established a sample preparation protocol for glass and membrane slides including manual coating of membrane slides with CryoJane solutions, cryosectioning, slide staining and dissection procedure, lysis and RNA extraction that facilitated efficient dissection and high quality RNA retrieval from CryoJane preparations. CryoJane technology therefore has the potential to facilitate standardization of laser microdissection slide preparation from frozen tissues. PMID:23805281
Anti-inflammatory activity of Shirishavaleha: An Ayurvedic compound formulation.
Yadav, Shyamlal Singh; Galib; Ravishankar, B; Prajapati, P K; Ashok, B K; Varun, B
2010-10-01
The purpose of the present study was to evaluate the anti-inflammatory activity of Shirishavaleha prepared from two different parts of Shirisha (Albizia lebbeck Benth.), viz. the bark (Twak) and the heartwood (Sara). The activity was screened in the carrageenan-induced rat paw edema model in albino rats. The raw materials were collected and authenticated in the university and the trial formulations were prepared by following standard classical guidelines. Randomly selected animals were divided into four groups of six animals each. The test drugs were administered orally at a dose of 1.8 g/kg for 5 days. Phenylbutazone was used as the standard anti-inflammatory drug for comparison. Between the two different test samples studied, the formulation made from heartwood showed a weak anti-inflammatory activity in this model while that made from the bark produced a considerable suppression of edema after 6 h. It appears that the bark sample would be preferable for clinical use.
Bladergroen, Marco R.; van der Burgt, Yuri E. M.
2015-01-01
For large-scale and standardized applications in mass spectrometry- (MS-) based proteomics automation of each step is essential. Here we present high-throughput sample preparation solutions for balancing the speed of current MS-acquisitions and the time needed for analytical workup of body fluids. The discussed workflows reduce body fluid sample complexity and apply for both bottom-up proteomics experiments and top-down protein characterization approaches. Various sample preparation methods that involve solid-phase extraction (SPE) including affinity enrichment strategies have been automated. Obtained peptide and protein fractions can be mass analyzed by direct infusion into an electrospray ionization (ESI) source or by means of matrix-assisted laser desorption ionization (MALDI) without further need of time-consuming liquid chromatography (LC) separations. PMID:25692071
Development of a Novel Self-Enclosed Sample Preparation Device for DNA/RNA Isolation in Space
NASA Technical Reports Server (NTRS)
Zhang, Ye; Mehta, Satish K.; Pensinger, Stuart J.; Pickering, Karen D.
2011-01-01
Modern biology techniques present potentials for a wide range of molecular, cellular, and biochemistry applications in space, including detection of infectious pathogens and environmental contaminations, monitoring of drug-resistant microbial and dangerous mutations, identification of new phenotypes of microbial and new life species. However, one of the major technological blockades in enabling these technologies in space is a lack of devices for sample preparation in the space environment. To overcome such an obstacle, we constructed a prototype of a DNA/RNA isolation device based on our novel designs documented in the NASA New Technology Reporting System (MSC-24811-1/3-1). This device is self-enclosed and pipette free, purposely designed for use in the absence of gravity. Our design can also be modified easily for preparing samples in space for other applications, such as flowcytometry, immunostaining, cell separation, sample purification and separation according to its size and charges, sample chemical labeling, and sample purification. The prototype of our DNA/RNA isolation device was tested for efficiencies of DNA and RNA isolation from various cell types for PCR analysis. The purity and integrity of purified DNA and RNA were determined as well. Results showed that our developed DNA/RNA isolation device offers similar efficiency and quality in comparison to the samples prepared using the standard protocol in the laboratory.
Lamazza, Luca; Garreffa, Girolamo; Laurito, Domenica; Lollobrigida, Marco; Palmieri, Luigi; De Biase, Alberto
2016-01-01
Various parameters can influence temperature rise and detection during implant site preparation. The aim of this study is to investigate local temperature values in cortical and corticocancellous bovine bone during early stages of piezoelectric implant site preparation. 20 osteotomies were performed using a diamond tip (IM1s, Mectron Medical Technology, Carasco, Italy) on two different types of bovine bone samples, cortical and corticocancellous, respectively. A standardized protocol was designed to provide constant working conditions. Temperatures were measured in real time at a fixed position by a fiber optic thermometer. Significantly higher drilling time (154.90 sec versus 99.00 sec; p < 0.0001) and temperatures (39.26°C versus 34.73°C; p = 0.043) were observed in the cortical group compared to the corticocancellous group. A remarkable variability of results characterized the corticocancellous blocks as compared to the blocks of pure cortical bone. Bone samples can influence heat generation during in vitro implant site preparation. When compared to cortical bone, corticocancellous samples present more variability in temperature values. Even controlling most experimental factors, the impact of bone samples still remains one of the main causes of temperature variability.
On the measurement of austenite in supermartensitic stainless steel by X-ray diffraction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tolchard, Julian Richard, E-mail: tolchard@material.ntnu.no; Sømme, Astri; Solberg, Jan Ketil
2015-01-15
Sections of a 13Cr supermartensitic stainless steel were investigated to determine the optimum sample preparation for measurement of the austenite content by X-ray diffraction. The surface of several samples was mechanically ground or polished using media of grit sizes in the range 1–120 μm. The strained surface layer was afterwards removed stepwise by electropolishing, and the austenite content measured at each step. It was found that any level of mechanical grinding or polishing results in a reduction of the measured austenite fraction relative to the true bulk value, and that coarser grinding media impart greater damage and greater reduction inmore » the measured austenite content. The results thus highlight the importance of the electropolishing step in preparation of such samples, but suggest that the American Society for Testing and Materials standard E975-03 substantially overestimates the amount of material which needs to be removed to recover the true “bulk” content. - Highlights: • Quantitative Rietveld analysis of austenite/martensite ratio in supermartensitic stainless steels • Critical evaluation of sample preparation for residual austenite measurements by X-ray diffraction • Highlighting of the importance of electropolishing as a final preparation step.« less
Application of PLE for the determination of essential oil components from Thymus vulgaris L.
Dawidowicz, Andrzej L; Rado, Ewelina; Wianowska, Dorota; Mardarowicz, Marek; Gawdzik, Jan
2008-08-15
Essential plants, due to their long presence in human history, their status in culinary arts, their use in medicine and perfume manufacture, belong to frequently examined stock materials in scientific and industrial laboratories. Because of a large number of freshly cut, dried or frozen plant samples requiring the determination of essential oil amount and composition, a fast, safe, simple, efficient and highly automatic sample preparation method is needed. Five sample preparation methods (steam distillation, extraction in the Soxhlet apparatus, supercritical fluid extraction, solid phase microextraction and pressurized liquid extraction) used for the isolation of aroma-active components from Thymus vulgaris L. are compared in the paper. The methods are mainly discussed with regard to the recovery of components which typically exist in essential oil isolated by steam distillation. According to the obtained data, PLE is the most efficient sample preparation method in determining the essential oil from the thyme herb. Although co-extraction of non-volatile ingredients is the main drawback of this method, it is characterized by the highest yield of essential oil components and the shortest extraction time required. Moreover, the relative peak amounts of essential components revealed by PLE are comparable with those obtained by steam distillation, which is recognized as standard sample preparation method for the analysis of essential oils in aromatic plants.
The purpose of this SOP is to describe procedures for extracting and preparing a dermal wipe sample for GC/MS analysis of pesticides. This procedure was followed to ensure consistent data retrieval during the Arizona NHEXAS project and the Border study. Keywords: dermal wipe; p...
The purpose of this SOP is to describe the procedures for collecting surface wipe samples inside a home for analysis of either metals or pesticides. This procedure covers the preparation of the surface wipe material and field activities. This protocol was followed to ensure con...
The purpose of this SOP is to describe the procedures for collecting a dermal wipe sample from a participant's hands for the measurement of pesticide or metal residues on the skin. This procedure covers the preparation of the dermal wipe material and field activities. This prot...
The purpose of this SOP is to describe procedures for extracting and preparing a dust or soil sample for gas chromatography mass spectrometry (GC/MS) analysis of pesticides and polyaromatic hydrocarbons (PAHs). This procedure was followed to ensure consistent data retrieval durin...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moran, James; Alexander, Thomas; Aalseth, Craig
2017-08-01
Previous measurements have demonstrated the wealth of information that tritium (T) can provide on environmentally relevant processes. We present modifications to sample preparation approaches that enable T measurement by proportional counting on small sample sizes equivalent to 120 mg of water and demonstrate the accuracy of these methods on a suite of standardized water samples. This enhanced method should provide the analytical flexibility needed to address persistent knowledge gaps in our understanding of T behavior in the environment.
Blood Sampling and Preparation Procedures for Proteomic Biomarker Studies of Psychiatric Disorders.
Guest, Paul C; Rahmoune, Hassan
2017-01-01
A major challenge in proteomic biomarker discovery and validation for psychiatric diseases is the inherent biological complexity underlying these conditions. There are also many technical issues which hinder this process such as the lack of standardization in sampling, processing and storage of bio-samples in preclinical and clinical settings. This chapter describes a reproducible procedure for sampling blood serum and plasma that is specifically designed for maximizing data quality output in two-dimensional gel electrophoresis, multiplex immunoassay and mass spectrometry profiling studies.
Trace Chemical Analysis Methodology
1980-04-01
oxidation of nitrite-containing species. Calibration studies were then made in preparation for the analysis of unknown samples of nitrate in urine and...the procedure for nitrate determination was made on two types of samples : human urine , and drinking water from a city water supply. Five samples of...AND URINE Concentration Standard Sample type of NO3, ppm deviation Drinking water 1.29 ±0 04 1.20 ±0.09 1.29 ±0.14 1.15 ±0.08 0.88 ±0.07 Human urine
Poster, Dianne L.; Schantz, Michele M.; Leigh, Stefan D.; Wise, Stephen A.
2004-01-01
Six Standard Reference Materials (SRMs®) have been prepared by the National Institute of Standards and Technology (NIST) for the determination of PCBs as different Aroclor mixtures in methanol. Six additional SRMs of the same Aroclors in transformer oil have also been prepared. Specifically, solutions of Aroclors 1016, 1232, 1242, 1254, and 1260 have been gravimetrically prepared (individually) in methanol and transformer oil, mixed, and transferred to amber glass ampoules in approximately 1.2 mL aliquots. Gas chromatography with electron capture detection (GC-ECD) has been used to verify the gravimetric data for each solution and transformer oil SRM. Liquid chromatography was used for the isolation of the Aroclors from the transformer oil SRMs prior to GC-ECD analysis. Separate calibration solutions and oils were prepared with Aroclor levels similar to those in each methanol solution and transformer oil SRM and were processed alongside the samples. The GC-ECD response of each Aroclor was monitored relative to internal standards that were added to the complex mixtures for quantification. The gravimetric concentrations of Aroclors 1242 and 1254 in methanol were also examined by the same method of analysis (GC-ECD) using several different sources of Aroclors and two different capillary GC columns: a 5 % phenyl methylpolysiloxane phase and a relatively non-polar phase. The preparation of the materials, the gas chromatographic results, and the certified concentration values for each Aroclor SRM are described in this paper. PMID:27366608
Torres, D P; Martins-Teixeira, M B; Silva, E F; Queiroz, H M
2012-01-01
A very simple and rapid method for the determination of total mercury in fish samples using the Direct Mercury Analyser DMA-80 was developed. In this system, a previously weighted portion of fresh fish is combusted and the released mercury is selectively trapped in a gold amalgamator. Upon heating, mercury is desorbed from the amalgamator, an atomic absorption measurement is performed and the mercury concentration is calculated. Some experimental parameters have been studied and optimised. In this study the sample mass was about 100.0 mg. The relative standard deviation was lower than 8.0% for all measurements of solid samples. Two calibration curves against aqueous standard solutions were prepared through the low linear range from 2.5 to 20.0 ng of Hg, and the high linear range from 25.0 to 200.0 ng of Hg, for which a correlation coefficient better than 0.997 was achieved, as well as a normal distribution of the residuals. Mercury reference solutions were prepared in 5.0% v/v nitric acid medium. Lyophilised fish tissues were also analysed; however, the additional procedure had no advantage over the direct analysis of the fresh fish, and additionally increased the total analytical process time. A fish tissue reference material, IAEA-407, was analysed and the mercury concentration was in agreement with the certified value, according to the t-test at a 95% confidence level. The limit of quantification (LOQ), based on a mercury-free sample, was 3.0 µg kg(-1). This LOQ is in accordance with performance criteria required by the Commission Regulation No. 333/2007. Simplicity and high efficiency, without the need for any sample preparation procedure, are some of the qualities of the proposed method.
Deconinck, Eric; Custers, Deborah; De Beer, Jacques Omer
2015-01-01
The standard procedures for the identification, authentication, and quality control of medicinal plants and herbs are nowadays limited to pure herbal products. No guidelines or procedures, describing the detection or identification of a targeted plant or herb in pharmaceutical preparations or dietary supplements, can be found. In these products the targeted plant is often present together with other components of herbal or synthetic origin. This chapter describes a strategy for the fast development of a chromatographic fingerprint approach that allows the identification of a targeted plant in herbal preparations and dietary supplements. The strategy consists of a standard chromatographic gradient that is tested for the targeted plant with different extraction solvents and different mobile phases. From the results obtained, the optimal fingerprint is selected. Subsequently the samples are analyzed according to the selected methodological parameters, and the obtained fingerprints can be compared with the one obtained for the pure herbal product or a standard preparation. Calculation of the dissimilarity between these fingerprints will result in a probability of presence of the targeted plant. Optionally mass spectrometry can be used to improve specificity, to confirm identification, or to identify molecules with a potential medicinal or antioxidant activity.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhou, Jianying; Dann, Geoffrey P.; Shi, Tujin
2012-03-10
Sodium dodecyl sulfate (SDS) is one of the most popular laboratory reagents used for highly efficient biological sample extraction; however, SDS presents a significant challenge to LC-MS-based proteomic analyses due to its severe interference with reversed-phase LC separations and electrospray ionization interfaces. This study reports a simple SDS-assisted proteomic sample preparation method facilitated by a novel peptide-level SDS removal protocol. After SDS-assisted protein extraction and digestion, SDS was effectively (>99.9%) removed from peptides through ion substitution-mediated DS- precipitation with potassium chloride (KCl) followed by {approx}10 min centrifugation. Excellent peptide recovery (>95%) was observed for less than 20 {mu}g of peptides.more » Further experiments demonstrated the compatibility of this protocol with LC-MS/MS analyses. The resulting proteome coverage from this SDS-assisted protocol was comparable to or better than those obtained from other standard proteomic preparation methods in both mammalian tissues and bacterial samples. These results suggest that this SDS-assisted protocol is a practical, simple, and broadly applicable proteomic sample processing method, which can be particularly useful when dealing with samples difficult to solubilize by other methods.« less
Arning, Erland; Bottiglieri, Teodoro
2016-01-01
We describe a simple stable isotope dilution method for accurate and precise measurement of γ-aminobutyric acid (GABA), a major inhibitory neurotransmitter in human cerebrospinal fluid (CSF) as a clinical diagnostic test. Determination of GABA in CSF (50 μL) was performed utilizing high performance liquid chromatography coupled with electrospray positive ionization tandem mass spectrometry (HPLC-ESI-MS/MS). Analysis of free and total GABA requires two individual sample preparations and mass spectrometry analyses. Free GABA in CSF is determined by a 1:2 dilution with internal standard (GABA-D2) and injected directly onto the HPLC-ESI-MS/MS system. Determination of total GABA in CSF requires additional sample preparation in order to hydrolyze all the bound GABA in the sample to the free form. This requires hydrolyzing the sample by boiling in acidic conditions (hydrochloric acid) for 4 h. The sample is then further diluted 1:10 with a 90 % acetonitrile/0.1 % formic acid solution and injected into the HPLC-ESI-MS/MS system. Each assay is quantified using a five-point standard curve and is linear from 6 nM to 1000 nM and 0.63 μM to 80 μM for free and total GABA, respectively.
NASA Astrophysics Data System (ADS)
de Souza, Roseli M.; Mathias, Bárbara M.; da Silveira, Carmem Lúcia P.; Aucélio, Ricardo Q.
2005-06-01
The quantitative evaluation of trace elements in foodstuffs is of considerable interest due to the potential toxicity of many elements, and because the presence of some metallic species might affect the overall quality (flavor and stability) of these products. In the present work, an inductively coupled plasma optical emission spectrometric method has been developed for the determination of six elements (Cd, Co, Cr, Cu, Ni and Mn) in olive oil, soy oil, margarine and butter. Organic samples (oils and fats) were stabilized using propan-1-ol and water, which enabled long-time sample dispersion in the solution. This simple sample preparation procedure, together with an efficient sample introduction strategy (using a Meinhard K3 nebulizer and a twister cyclonic spray chamber), facilitated the overall analytical procedure, allowing quantification using calibration curves prepared with inorganic standards. Internal standardization (Sc) was used for correction of matrix effects and signal fluctuations. Good sensitivities with limits of detection in the ng g -1 range were achieved for all six elements. These sensitivities were appropriate for the intended application. The method was tested through the analysis of laboratory-fortified samples with good recoveries (between 91.3% and 105.5%).
Hofmann, D; Gehre, M; Jung, K
2003-09-01
In order to identify natural nitrogen isotope variations of biologically important amino acids four derivatization reactions (t-butylmethylsilylation, esterification with subsequent trifluoroacetylation, acetylation and pivaloylation) were tested with standard mixtures of 17 proteinogenic amino acids and plant (moss) samples using GC-C-IRMS. The possible fractionation of the nitrogen isotopes, caused for instance by the formation of multiple reaction products, was investigated. For biological samples, the esterification of the amino acids with subsequent trifluoroacetylation is recommended for nitrogen isotope ratio analysis. A sample preparation technique is described for the isotope ratio mass spectrometric analysis of amino acids from the non-protein (NPN) fraction of terrestrial moss. 14N/15N ratios from moss (Scleropodium spec.) samples from different anthropogenically polluted areas were studied with respect to ecotoxicologal bioindication.
Noori, Muhammad Yahya; AJi, Zaheer; Khan, Ghazala; Sharafat, Shaheen; Masroor, Muhammad
2015-01-01
Mycobacterial culture is considered as the gold standard for TB diagnosis. It is performed on egg-based media using commercially available eggs to grow Mycobacteria from clinical samples. These eggs are known to contain high concentration of antibiotics, including fluoroquinolones, given to chicken to prevent early mortality. This study was performed to compare Mycobacterial growth on media prepared from commercial and antibiotic free household eggs. Sputum samples from negative (No bacilli in 100 oil immersion field), scanty (1-9 AFB in 100 fields), 1+ (10-99 bacilli per field), 2+ (1-10 bacilli per field) and 3+ (>10 bacilli per field) were inoculated dually on Ogawa medium prepared from commercial and household eggs. Tubes were inspected every fourth day for the appearance of colonies till 60 days. Data tabulations and statistical analysis (F test for variation and unpaired Student's t test) were performed on Microsoft Excel. One microscopically negative sample showed growth on media prepared from household eggs, while all were negative on that prepared from commercial eggs. There were significant differences in time to culture positivity for samples graded 1+ (p = 0.02), 2+ (p = 0.002) and 3+ (p = 0.0003). Commercial eggs containing antibiotics can be a source of false negativity in cultures especially in microscopically negative samples. This can be of special concern in HIV patients who have high smear negativity. It is therefore important to either develop provision of antibiotic free eggs for media preparation or to develop and validate other laboratory investigations for smear negative TB patients.
7 CFR 996.12 - Outgoing inspection.
Code of Federal Regulations, 2010 CFR
2010-01-01
... STANDARDS FOR DOMESTIC AND IMPORTED PEANUTS MARKETED IN THE UNITED STATES Definitions § 996.12 Outgoing inspection. Outgoing inspection means the sampling, inspection, and certification of either: shelled peanuts... peanuts which have been cleaned, sorted, and otherwise prepared for inshell human consumption markets. ...
7 CFR 996.12 - Outgoing inspection.
Code of Federal Regulations, 2011 CFR
2011-01-01
... STANDARDS FOR DOMESTIC AND IMPORTED PEANUTS MARKETED IN THE UNITED STATES Definitions § 996.12 Outgoing inspection. Outgoing inspection means the sampling, inspection, and certification of either: shelled peanuts... peanuts which have been cleaned, sorted, and otherwise prepared for inshell human consumption markets. ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kumar, Sandeep, E-mail: sandeep0078monu@gmail.com; Singh, Sukhpal, E-mail: sukhpal-78@rediffmail.com
2016-05-06
Five samples of Bismuth-Ground granulated blast furnace slag (Bi-GGBFS) concretes were prepared using composition (0.6 cement + x Bi{sub 2}O{sub 3} + (0.4-x) GGBFS, x = 0.05, 0.10, 0.15, 0.20 and 0.25) by keeping constant water (W) cement (C) ratio. Mass attenuation coefficients (μ{sub m}) of these prepared samples were calculated using a computer program winXCOM at different gamma ray energies, whereas effective atomic numbers (Z{sub eff}) is calculated using mathematical formulas. The radiation shielding properties of Bi-GGBFS concrete has been compared with standard radiation shielding concretes.
Mulberrry, G; Snyder, A T; Heilman, J; Pyrek, J; Stahl, J
2001-12-01
A new waterless surgical hand preparation containing 1% chlorhexidine gluconate (CHG) and 61% ethyl alcohol was evaluated for antimicrobial efficacy in comparison with a standard 4% CHG surgical scrub and a 61% ethyl alcohol control. Clinical studies were based on the Tentative Final Monograph for Health-Care Antiseptic Drug Products (TFM) (proposed rule) and the Standard Test Method for Evaluation of Surgical Hand Scrub Formulations (ASTM E1115-91). Two randomized, blinded, well-controlled clinical studies involving 137 healthy subjects were conducted to evaluate the antimicrobial effectiveness of the CHG/ethanol hand preparation in producing an immediate and persistent reduction in the normal bacterial flora of the hands. The CHG/ethanol hand preparation was applied without scrubbing or the use of water, and a standard 4% CHG reference product was applied with a scrub brush in 2 traditional 3-minute surgical scrubs. In 1 study, a 61% ethanol vehicle control treatment was applied without scrubbing or use of water. During a 5-day period, each study subject performed a series of 11 surgical scrubs with 1 of the test treatments. After the first treatment on days 1, 2, and 5, surgical gloves were worn for 3 or 6 hours. Bacterial samples were taken with the glove-juice technique at 1 minute, 3 hours, and 6 hours after treatment. The immediate bactericidal effect of the CHG/ethanol hand preparation after a single application resulted in a 2.5-log reduction in normal flora. This bactericidal effect persisted throughout the studies and eventually increased to a 3.6-log reduction after the 11th scrub on day 5. The log reductions of the CHG/ethanol hand preparation proved to be significantly better (P <.05) than that of the 4% CHG product at each sampling interval on days 1 and 2 and the sampling at 6 hours on day 5 and significantly better than the 61% ethanol vehicle at all times. The combination of 1% CHG and 61% ethanol had significantly greater microbial reduction than either the 4% CHG (without ethanol) or the 61% ethanol vehicle (without CHG).
NASA Technical Reports Server (NTRS)
Barta, D. J.; Tibbitts, T. W.
1991-01-01
An electron microprobe with wavelength-dispersive x-ray spectrometry (WDS) was found to be useful for the determination of Ca concentrations in leaf tissue deficient in Ca. WDS effectively detected Ca concentrations as low as 0.2 mg/g dry wt in the presence of high levels of K and Mg (120 and 50 mg/g dry wt, respectively). Leaf specimens were prepared for analysis by quick-freezing in liquid nitrogen and freeze-drying at -20 degrees C to maintain elemental integrity within the tissue. Because dry material was analyzed, sample preparation was simple and samples could be stored for long periods before analysis. A large beam diameter of 50 gm was used to minimize tissue damage under the beam and analyze mineral concentrations within several cells at one time. Beam penetration was between 50 and 55 microns, approximately one-third of the thickness of the leaf. For analysis of concentrations in interveinal areas, analyses directed into the abaxial epidermis were found most useful. However, because of limited beam penetration, analyses of veinal areas would require use of cross sections [correction of crosssections]. Solid mineral standards were used for instrument standardization. To prevent measurement errors resulting from differences between the matrix of the mineral standards and the analyzed tissue, concentrations in leaves were corrected using gelatin standards prepared and analyzed under the same conditions. WDS was found to be useful for documenting that very low Ca levels occur in specific areas of lettuce leaves exhibiting the Ca deficiency injury termed tipburn.
Olmos-Jiménez, Raquel; Espuny-Miró, Alberto; Díaz-Carrasco, María Sacramento; Fernández-Varón, Emilio; Valderrey-Pulido, Manuel; Cárceles-Rodríguez, Carlos
2016-10-01
Intrathecal administration of methotrexate, cytarabine, and hydrocortisone is commonly used to treat and prevent central nervous system involvement in leukemias and lymphomas. The use of intrathecal solutions with pH and osmolarity values close to physiologic range of CSF (pH 7.31-7.37, osmolarity 281-306 mOsm/kg) and standardization of the methotrexate, cytarabine, and hydrocortisone doses in children and adults based on age is highly recommended. Stability studies of standardized intrathecal mixtures under these conditions have not yet been published. The purpose of this study was to evaluate the physical and chemical stabilities of four standardized mixtures of methotrexate, cytarabine, and hydrocortisone stored at 2-8℃ and 25℃ up to 7 days after preparation. Four different standardized intrathecal mixtures were prepared and stored at 2-8℃ and 25℃ and protected from light. Triplicate samples were taken at different times and precipitation, appearance, color, pH, and osmolarity were analyzed. Methotrexate, cytarabine, and hydrocortisone concentrations were measured using a modified high-performance liquid chromatography method. No variation greater than 10% of the initial concentration of methotrexate, cytarabine, and hydrocortisone was observed in any of the four standardized mixtures for the 7 days of study when stored at 2-8℃ and 25℃ and protected from light. The osmolarity of the four preparations was within the physiologic range of CSF for 7 days at both 2-8℃ and 25℃. The pH values close to the physiologic range of CSF were stable for 48 h at 25℃ and for 120 h at 2-8℃. Triple intrathecal standardized preparations of methotrexate, cytarabine, and hydrocortisone sodium phosphate are physically and chemically stable at 25℃ for 48 h and at 2-8℃ for 5 days. © The Author(s) 2015.
Femia, Eti Alessandra; Pugliano, Mariateresa; Podda, Gianmarco; Cattaneo, Marco
2012-01-01
Light transmission aggregometry (LTA), the gold standard for the study of patients with defects of platelet function, is a poorly standardized technique. The guidelines that have been produced so far are largely based on consensus of experts, due to the absence of studies directly comparing different procedures. Therefore, ad hoc studies are needed to gather scientific evidence on how to choose the most appropriate procedures for LTA measurement. In this study, we aimed at evaluating the most appropriate conditions for preparing samples of platelet-rich plasma (PRP) for studies of platelet aggregation by LTA. Citrate-anticoagulated blood from 32 individuals was centrifuged at 150, 200, 250 or 300×g at room temperature for 10 min. Red blood cells contamination was highest in PRP prepared at 150×g; mean platelet volume (MPV) was lowest in PRP prepared at 300×g. The extent of platelet aggregation measured by LTA was lower and more variable in PRP prepared at 300×g. Therefore, centrifugation of blood at 200×g or 250×g for 10 min appears to be the best condition for preparing PRP for LTA studies.
A new approach to preparation of standard LEDs for luminous intensity and flux measurement of LEDs
NASA Astrophysics Data System (ADS)
Park, Seung-Nam; Park, Seongchong; Lee, Dong-Hoon
2006-09-01
This work presents an alternative approach for preparing photometric standard LEDs, which is based on a novel functional seasoning method. The main idea of our seasoning method is simultaneously monitoring the light output and the junction voltage to obtain quantitative information on the temperature dependence and the aging effect of the LED emission. We suggested a general model describing the seasoning process by taking junction temperature variation and aging effect into account and implemented a fully automated seasoning facility, which is capable of seasoning 12 LEDs at the same time. By independent measurements of the temperature dependence, we confirmed the discrepancy of the theoretical model to be less than 0.5 % and evaluate the uncertainty contribution of the functional seasoning to be less than 0.5 % for all the seasoned samples. To demonstrate assigning the reference value to a standard LED, the CIE averaged LED intensity (ALI) of the seasoned LEDs was measured with a spectroradiometer-based instrument and the measurement uncertainty was analyzed. The expanded uncertainty of the standard LED prepared by the new approach amounts to be 4 % ~ 5 % (k=2) depending on color without correction of spectral stray light in the spectroradiometer.
ERIC Educational Resources Information Center
Troia, Gary A.; Graham, Steve
2016-01-01
A random sample of 482 teachers in grades 3 through 8 from across the United States were surveyed about (a) their perceptions of the version of the Common Core writing and language standards adopted by their state and their state's writing assessment, (b) their preparation to teach writing, and (c) their self-efficacy beliefs for teaching writing.…
Validation of the Filovirus Plaque Assay for Use in Preclinical Studies
2016-09-02
filoviruses in virus stocks, prepared viral challenge inocula and samples from research animals has recently been fully characterized and standardized for...and robust for filovirus titration in samples associated with the performance of GLP animal model studies. Keywords: Plaque assay; filovirus; Ebola...ebolavirus; marburgvirus; Marburg virus; Vero E6 cells; GLP compliant; validation; animal rule DISTRIBUTION STATEMENT A: Approved for public
The purpose of this SOP is to describe the procedures for collecting a dermal wipe sample from a participant's hands for the measurement of pesticide or metal residues on the skin. This procedure covers the preparation of the dermal wipe material and field activities. This prot...
Matrix normalized MALDI-TOF quantification of a fluorotelomer-based acrylate polymer.
Rankin, Keegan; Mabury, Scott A
2015-05-19
The degradation of fluorotelomer-based acrylate polymers (FTACPs) has been hypothesized to serve as a source of the environmental contaminants, perfluoroalkyl carboxylates (PFCAs). Studies have relied on indirect measurement of presumed degradation products to evaluate the environmental fate of FTACPs; however, this approach leaves a degree of uncertainty. The present study describes the development of a quantitative matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry method as the first direct analysis method for FTACPs. The model FTACP used in this study was poly(8:2 FTAC-co-HDA), a copolymer of 8:2 fluorotelomer acrylate (8:2 FTAC) and hexadecyl acrylate (HDA). Instead of relying on an internal standard polymer, the intensities of 40 poly(8:2 FTAC-co-HDA) signals (911-4612 Da) were normalized to the signal intensity of a matrix-sodium cluster (659 Da). We termed this value the normalized polymer response (P(N)). By using the same dithranol solution for the sample preparation of poly(8:2 FTAC-co-HDA) standards, calibration curves with coefficient of determinations (R(2)) typically >0.98 were produced. When poly(8:2 FTAC-co-HDA) samples were prepared with the same dithranol solution as the poly(8:2 FTAC-co-HDA) standards, quantification to within 25% of the theoretical concentration was achieved. This approach minimized the sample-to-sample variability that typically plagues MALDI-TOF, and is the first method developed to directly quantify FTACPs.
Extraction and derivatization of polar herbicides for GC-MS analyses.
Ranz, Andreas; Maier, Eveline; Motter, Herbert; Lankmayr, Ernst
2008-09-01
A sample preparation procedure including a simultaneous microwave-assisted (MA) extraction and derivatization for the determination of chlorophenoxy acids in soil samples is presented. For a selective and sensitive measurement, an analytical technique such as GC coupled with MS needs to be adopted. For GC analyses, chlorophenoxy acids have to be converted into more volatile and thermally stable derivatives. Derivatization by means of microwave radiation offers new alternatives in terms of shorter derivatization time and reduces susceptibility for the formation of artefacts. Extraction and derivatization into methyl esters (ME) were performed with sulphuric acid and methanol. Due to the novelty of the simultaneous extraction and derivatization assisted by means of microwave radiation, a careful investigation and optimization of influential reaction parameters was necessary. It could be shown that the combination of sulphuric acid and methanol provides a fast sample preparation including an efficient clean up procedure. The data obtained by the described method are in good agreement with those published for the reference material. Finally, compared to conventional heating and also to the standard procedure of the EPA, the sample preparation time could be considerably shortened.
Measurement of trace elements in tree rings using the PIXE method
NASA Astrophysics Data System (ADS)
Aoki, Toru; Katayama, Yukio; Kagawa, Akira; Koh, Susumu; Yoshida, Kohji
1998-03-01
Standard materials were prepared in order to calculate element concentrations in tree samples using the particle induced X-ray emission (PIXE) method. Five standard solutions (1) Ti, Fe, Cu, As, Rb, Sr; (2) Ca, V, Co, Zn, As, Rb; (3) Ti, Mn, Ni, As, Sr; (4) K, Mn, Co, As, Rb, Sr; and (5) Ca, Mn, Cu, As, Rb, Sr, were added to filter papers. The dried filter papers were used as standard samples. Pellets of Pepperbush leaves (National Institute for Environmental Studies (NIES)) and Peach leaves (National Institute of Standards and Technology (NIST)) were used as references. The peak counts of Ca, Mn, Cu, Zn, Rb, and Sr in samples taken from a kaki ( Diospros kaki Thunb.) were measured and the concentrations (ppm) of the elements were calculated using the yield curve obtained from the standard filter papers. The concentrations of Mn, Zn, Rb, and Ca were compared with the data obtained from a separate INAA analysis. Concentrations of Mn, Zn, and Ca obtained by both methods were almost the same, but the concentrations of Rb differed slightly. The amounts of trace elements in samples taken from a sugi ( Cryptomeria japonica D. Don) were also measured.
Trépout, Sylvain; Bastin, Philippe; Marco, Sergio
2017-03-12
This report describes a protocol for preparing thick biological specimens for further observation using a scanning transmission electron microscope. It also describes an imaging method for studying the 3D structure of thick biological specimens by scanning transmission electron tomography. The sample preparation protocol is based on conventional methods in which the sample is fixed using chemical agents, treated with a heavy atom salt contrasting agent, dehydrated in a series of ethanol baths, and embedded in resin. The specific imaging conditions for observing thick samples by scanning transmission electron microscopy are then described. Sections of the sample are observed using a through-focus method involving the collection of several images at various focal planes. This enables the recovery of in-focus information at various heights throughout the sample. This particular collection pattern is performed at each tilt angle during tomography data collection. A single image is then generated, merging the in-focus information from all the different focal planes. A classic tilt-series dataset is then generated. The advantage of the method is that the tilt-series alignment and reconstruction can be performed using standard tools. The collection of through-focal images allows the reconstruction of a 3D volume that contains all of the structural details of the sample in focus.
Song, Zewei; Schlatter, Dan; Kennedy, Peter; Kinkel, Linda L.; Kistler, H. Corby; Nguyen, Nhu; Bates, Scott T.
2015-01-01
Next generation fungal amplicon sequencing is being used with increasing frequency to study fungal diversity in various ecosystems; however, the influence of sample preparation on the characterization of fungal community is poorly understood. We investigated the effects of four procedural modifications to library preparation for high-throughput sequencing (HTS). The following treatments were considered: 1) the amount of soil used in DNA extraction, 2) the inclusion of additional steps (freeze/thaw cycles, sonication, or hot water bath incubation) in the extraction procedure, 3) the amount of DNA template used in PCR, and 4) the effect of sample pooling, either physically or computationally. Soils from two different ecosystems in Minnesota, USA, one prairie and one forest site, were used to assess the generality of our results. The first three treatments did not significantly influence observed fungal OTU richness or community structure at either site. Physical pooling captured more OTU richness compared to individual samples, but total OTU richness at each site was highest when individual samples were computationally combined. We conclude that standard extraction kit protocols are well optimized for fungal HTS surveys, but because sample pooling can significantly influence OTU richness estimates, it is important to carefully consider the study aims when planning sampling procedures. PMID:25974078
Yoakum, A M; Stewart, P L; Sterrett, J E
1975-01-01
An emission spectrochemical method is described for the determination of trace quantities of platinum, lead, and manganese in biological tissues. Total energy burns in an argon-oxygen atmosphere are employed. Sample preparation, conditions of analysis, and preparation of standards are discussed. The precision of the method is consistently better than +/- 15%, and comparative analyses indicate comparable accuracies. Data obtained for experimental rat tissues and for selected autopsy tissues are presented. PMID:1157798
Comparison of two confocal micro-XRF spectrometers with different design aspects
Smolek, S; Nakazawa, T; Tabe, A; Nakano, K; Tsuji, K; Streli, C; Wobrauschek, P
2014-01-01
Two different confocal micro X-ray fluorescence spectrometers have been developed and installed at Osaka City University and the Vienna University of Technology Atominstitut. The Osaka City University system is a high resolution spectrometer operating in air. The Vienna University of Technology Atominstitut spectrometer has a lower spatial resolution but is optimized for light element detection and operates under vacuum condition. The performance of both spectrometers was compared. In order to characterize the spatial resolution, a set of nine specially prepared single element thin film reference samples (500 nm in thickness, Al, Ti, Cr, Fe Ni, Cu, Zr, Mo, and Au) was used. Lower limits of detection were determined using the National Institute of Standards and Technology standard reference material glass standard 1412. A paint layer sample (cultural heritage application) and paint on automotive steel samples were analyzed with both instruments. The depth profile information was acquired by scanning the sample perpendicular to the surface. © 2013 The Authors. X-Ray Spectrometry published by John Wiley & Sons, Ltd. PMID:26430286
Comparison of two confocal micro-XRF spectrometers with different design aspects.
Smolek, S; Nakazawa, T; Tabe, A; Nakano, K; Tsuji, K; Streli, C; Wobrauschek, P
2014-03-01
Two different confocal micro X-ray fluorescence spectrometers have been developed and installed at Osaka City University and the Vienna University of Technology Atominstitut. The Osaka City University system is a high resolution spectrometer operating in air. The Vienna University of Technology Atominstitut spectrometer has a lower spatial resolution but is optimized for light element detection and operates under vacuum condition. The performance of both spectrometers was compared. In order to characterize the spatial resolution, a set of nine specially prepared single element thin film reference samples (500 nm in thickness, Al, Ti, Cr, Fe Ni, Cu, Zr, Mo, and Au) was used. Lower limits of detection were determined using the National Institute of Standards and Technology standard reference material glass standard 1412. A paint layer sample (cultural heritage application) and paint on automotive steel samples were analyzed with both instruments. The depth profile information was acquired by scanning the sample perpendicular to the surface. © 2013 The Authors. X-Ray Spectrometry published by John Wiley & Sons, Ltd.
MICROWAVE-ASSISTED EXTRACTION OF ORGANIC COMPOUNDS FROM STANDARD REFERENCE SOILS AND SEDIMENTS
As part of an ongoing evaluation of new sample preparation techniques by the U.S. Environmental Protection Agency (EPA), especially those that minimize waste solvents, microwave-assisted extraction (MAE) of organic compounds from solid materials (or "matrices") was evaluated. Six...
Anti-inflammatory activity of Shirishavaleha: An Ayurvedic compound formulation
Yadav, Shyamlal Singh; Galib; Ravishankar, B.; Prajapati, P.K.; Ashok, B.K.; Varun, B.
2010-01-01
The purpose of the present study was to evaluate the anti-inflammatory activity of Shirishavaleha prepared from two different parts of Shirisha (Albizia lebbeck Benth.), viz. the bark (Twak) and the heartwood (Sara). The activity was screened in the carrageenan-induced rat paw edema model in albino rats. The raw materials were collected and authenticated in the university and the trial formulations were prepared by following standard classical guidelines. Randomly selected animals were divided into four groups of six animals each. The test drugs were administered orally at a dose of 1.8 g/kg for 5 days. Phenylbutazone was used as the standard anti-inflammatory drug for comparison. Between the two different test samples studied, the formulation made from heartwood showed a weak anti-inflammatory activity in this model while that made from the bark produced a considerable suppression of edema after 6 h. It appears that the bark sample would be preferable for clinical use. PMID:21455445
Prendergast, Jocelyn L; Sniegoski, Lorna T; Welch, Michael J; Phinney, Karen W
2010-07-01
The definitive method (DM), now known as the reference measurement procedure (RMP), for the analysis of glucose in serum was originally published in 1982 by the National Institute of Standards and Technology (NIST). Over the years the method has been subject to a number of modifications to adapt to newer technologies and simplify sample preparation. We discuss here an adaptation of the method associated with serum glucose measurements using a modified isotope dilution gas chromatography/mass spectrometry (ID-GC/MS) method. NIST has used this modified method to certify the concentrations of glucose in SRM 965b, Glucose in Frozen Human Serum, and SRM 1950, Metabolites in Human Plasma. Comparison of results from the revised method with certified values for existing Standard Reference Materials (SRMs) demonstrated that these modifications have not affected the quality of the measurements, giving both good precision and accuracy, while reducing the sample preparation time by a day and a half.
Mosupye, F M; von Holy, A
2000-11-01
One hundred and thirty-two samples of beef, chicken, salad and gravy were collected from two street vendors over eleven replicate surveys to assess microbiological safety and quality. For each food type samples were collected during preparation and holding. Dish water was also collected and food preparation surfaces swabbed during preparation and display. Standard methods were used to determine aerobic plate counts, Enterobacteriaceae counts, coliform counts and spore counts. Six hundred and seventy-five predominant colonies were isolated from aerobic plate counts of all samples and characterised. The incidence of selected foodborne bacterial pathogens and non-pathogenic E. coli 1 was also determined. In most cases mean bacterial counts of the raw materials were significantly higher (P < 0.05) than those of corresponding cooked foods. No significant differences (P > 0.05) in all count types were observed between food samples collected during cooking and those collected during holding. In addition, no significant differences (P > 0.05) in all count types were observed between prepared salads and their raw materials. Mean bacterial counts of water and swab samples collected from vendor 1 were lower than those of water and swab samples collected from vendor 2.The predominant populations isolated from the aerobic plate counts were Bacillus spp., Staphylococcus spp., Enterobacteriaceae and Alcaligenes spp. Bacillus cereus was detected in 17%, Clostridium perfringens in 1%, Staphylococcus aureus in 3% and Vibrio metchnikovii in 2% of the food samples. Campylobacter jejuni, Listeria monocytogenes, and Escherichia coli O157:H7 were not detected. Non-pathogenic E. coli 1 was detected in 13% of food samples, in 86 and 36% of dish water samples collected from vendors 1 and 2, respectively, and in 36% of surface swab samples from vendor 2.
230Th-234U Model-Ages of Some Uranium Standard Reference Materials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Williams, R W; Gaffney, A M; Kristo, M J
The 'age' of a sample of uranium is an important aspect of a nuclear forensic investigation and of the attribution of the material to its source. To the extent that the sample obeys the standard rules of radiochronometry, then the production ages of even very recent material can be determined using the {sup 230}Th-{sup 234}U chronometer. These standard rules may be summarized as (a) the daughter/parent ratio at time=zero must be known, and (b) there has been no daughter/parent fractionation since production. For most samples of uranium, the 'ages' determined using this chronometer are semantically 'model-ages' because (a) some assumptionmore » of the initial {sup 230}Th content in the sample is required and (b) closed-system behavior is assumed. The uranium standard reference materials originally prepared and distributed by the former US National Bureau of Standards and now distributed by New Brunswick Laboratory as certified reference materials (NBS SRM = NBL CRM) are good candidates for samples where both rules are met. The U isotopic standards have known purification and production dates, and closed-system behavior in the solid form (U{sub 3}O{sub 8}) may be assumed with confidence. We present here {sup 230}Th-{sup 234}U model-ages for several of these standards, determined by isotope dilution mass spectrometry using a multicollector ICP-MS, and compare these ages with their known production history.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wall, Mark A.
The development of our Integrated Actinide Sample Preparation Laboratory (IASPL) commenced in 1998 driven by the need to perform transmission electron microscopy studies on naturally aged plutonium and its alloys looking for the microstructural effects of the radiological decay process (1). Remodeling and construction of a laboratory within the Chemistry and Materials Science Directorate facilities at LLNL was required to turn a standard radiological laboratory into a Radiological Materials Area (RMA) and Radiological Buffer Area (RBA) containing type I, II and III workplaces. Two inert atmosphere dry-train glove boxes with antechambers and entry/exit fumehoods (Figure 1), having a baseline atmospheremore » of 1 ppm oxygen and 1 ppm water vapor, a utility fumehood and a portable, and a third double-walled enclosure have been installed and commissioned. These capabilities, along with highly trained technical staff, facilitate the safe operation of sample preparation processes and instrumentation, and sample handling while minimizing oxidation or corrosion of the plutonium. In addition, we are currently developing the capability to safely transfer small metallographically prepared samples to a mini-SEM for microstructural imaging and chemical analysis. The gloveboxes continue to be the most crucial element of the laboratory allowing nearly oxide-free sample preparation for a wide variety of LLNL-based characterization experiments, which includes transmission electron microscopy, electron energy loss spectroscopy, optical microscopy, electrical resistivity, ion implantation, X-ray diffraction and absorption, magnetometry, metrological surface measurements, high-pressure diamond anvil cell equation-of-state, phonon dispersion measurements, X-ray absorption and emission spectroscopy, and differential scanning calorimetry. The sample preparation and materials processing capabilities in the IASPL have also facilitated experimentation at world-class facilities such as the Advanced Photon Source at Argonne National Laboratory, the European Synchrotron Radiation Facility in Grenoble, France, the Stanford Synchrotron Radiation Facility, the National Synchrotron Light Source at Brookhaven National Laboratory, the Advanced Light Source at Lawrence Berkeley National Laboratory, and the Triumph Accelerator in Canada.« less
Seyfferth, Angelia L; Parker, David R
2006-03-22
A sample preparation method was developed to quantify environmentally relevant (low micrograms per liter) concentrations of perchlorate (ClO4(-)) in leafy vegetables using IC-ESI-MS. Lettuce and spinach were macerated, centrifuged, and filtered, and the aqueous extracts were rendered water-clear using a one-step solid-phase extraction method. Total time for extraction and sample preparation was 6 h. Ion suppression was demonstrated and was likely due to unknown organics still present in the extract solution after cleanup. However, this interference was readily eliminated using a Cl(18)O4(-) internal standard at 1 microg/L in all standards and samples. Hydroponically grown perchlorate-free butterhead lettuce was spiked to either 10.3 or 37.7 microg/kg of fresh weight (FW), and recoveries were between 91 and 98% and between 93 and 101%, respectively. Five types of lettuce and spinach from a local grocery store were then analyzed; they contained from 0.6 to 6.4 microg/kg of FW. Spike recoveries using the store-bought samples ranged from 89 to 100%. The method detection limit for perchlorate in plant extracts is 40 ng/L, and the corresponding minimum reporting limit is 200 ng/L or 0.8 microg/kg of FW.
Two High-Resolution, Quantitative, Infrared Spectral Libraries for Atmospheric Chemistry
NASA Astrophysics Data System (ADS)
Johnson, T. J.; Sharpe, S. W.; Sams, R. L.; Chu, P. M.
2001-12-01
The Pacific Northwest National Laboratory (PNNL) and the National Institute of Standards and Technology (NIST) are independently creating quantitative, 0.10 cm-1 resolution, infrared spectral libraries of vapor phase compounds. Both libraries contain many species of use to the gas-phase spectroscopist, including for atmospheric chemistry. The NIST library will consist of approximately 100 vapor phase spectra primarily associated with volatile hazardous air pollutants (HAPs) and suspected greenhouse gases, whereas the PNNL library will consist of approximately 400 vapor phase spectra associated with DOE's remediation mission. Data are being recorded from 600 to 6500 cm-1 to cover not only the classical fingerprint region, but much of the near-infrared as well. The wavelength axis is calibrated against published standards. To prepare the samples, the two laboratories use significantly different sample preparation and handling techniques: NIST uses gravimetric dilution and a continuous flowing sample while PNNL uses partial pressure dilution and a static sample. The data are validated against one another and agreement on the ordinate axis is generally found to be within the statistical uncertainties (2σ ) of the Beer's law fit and less than 3 % of the total integrated band areas for the 4 chemicals used in this comparison. The nature of the two databases and the rigorous nature used to acquire the data will be briefly discussed.
Bergström, M; Kieler, H; Waldenström, U
2009-01-01
Objective To examine the effects of antenatal education focussing on natural childbirth preparation with psychoprophylactic training versus standard antenatal education on the use of epidural analgesia, experience of childbirth and parental stress in first-time mothers and fathers. Design Randomised controlled multicentre trial. Setting Fifteen antenatal clinics in Sweden between January 2006 and May 2007. Sample A total of 1087 nulliparous women and 1064 of their partners. Methods Natural group: Antenatal education focussing on natural childbirth preparation with training in breathing and relaxation techniques (psychoprophylaxis). Standard care group: Standard antenatal education focussing on both childbirth and parenthood, without psychoprophylactic training. Both groups: Four 2-hour sessions in groups of 12 participants during third trimester of pregnancy and one follow-up after delivery. Main outcome measures Epidural analgesia during labour, experience of childbirth as measured by the Wijma Delivery Experience Questionnaire (B), and parental stress measured by the Swedish Parenthood Stress Questionnaire. Results The epidural rate was 52% in both groups. There were no statistically significant differences in the experience of childbirth or parental stress between the randomised groups, either in women or men. Seventy percent of the women in the Natural group reported having used psychoprophylaxis during labour. A minority in the Standard care group (37%) had also used this method, but subgroup analysis where these women were excluded did not change the principal findings. Conclusion Natural childbirth preparation including training in breathing and relaxation did not decrease the use of epidural analgesia during labour, nor did it improve the birth experience or affect parental stress in early parenthood in nulliparous women and men, compared with a standard form of antenatal education. PMID:19538406
Poetsch, Ansgar; Schlüsener, Daniela; Florizone, Christine; Eltis, Lindsay; Menzel, Christoph; Rögner, Matthias; Steinert, Kerstin; Roth, Udo
2008-01-01
Integral membrane proteins are notoriously difficult to identify and analyze by mass spectrometry because of their low abundance and limited number of trypsin cleavage sites. Our strategy to address this problem is based on a novel technology for MALDI-MS peptide sample preparation that increases the success rate of membrane protein identification by increasing the sensitivity of the MALDI-TOF system. For this, we used sample plates with predeposited matrix spots of CHCA crystals prepared by vacuum sublimation onto an extremely low wettable (ultraphobic) surface. In experiments using standard peptides, an up to 10-fold gain of sensitivity was found for on-chip preparations compared with classical dried-droplet preparations on a steel target. In order to assess the performance of the chips with membrane proteins, three model proteins (bacteriorhodopsin, subunit IV(a) of ATP synthase, and the cp47 subunit from photosystem II) were analyzed. To mimic realistic analysis conditions, purified proteins were separated by SDS-PAGE and digested with trypsin. The digest MALDI samples were prepared either by dried-droplet technique on steel plates using CHCA as matrix, or applied directly onto the matrix spots of the chip surface. Significantly higher signal-to-noise ratios were observed for all of the spectra resulting from on-chip preparations of different peptides. In a second series of experiments, the membrane proteome of Rhodococcus jostii RHA1 was investigated by AIEC/SDS-PAGE in combination with MALDI-TOF MS/MS. As in the first experiments, Coomassie-stained SDS-PAGE bands were digested and the two different preparation methods were compared. For preparations on the Mass·Spec·Turbo Chip, 43 of 60 proteins were identified, whereas only 30 proteins were reliably identified after classical sample preparation. Comparison of the obtained Mascot scores, which reflect the confidence level of the protein identifications, revealed that for 70% of the identified proteins, higher scores were obtained by on-chip sample preparation. Typically, this gain was a consequence of higher sequence coverage due to increased sensitivity. PMID:19137096
A PEG-Based Hydrogel for Effective Wound Care Management
Chen, Sen-Lu; Fu, Ru-Huei; Liao, Shih-Fei; Liu, Shih-Ping; Lin, Shinn-Zong; Wang, Yu-Chi
2018-01-01
It is extremely challenging to achieve strong adhesion in soft tissues while minimizing toxicity, tissue damage, and other side effects caused by wound sealing materials. In this study, flexible synthetic hydrogel sealants were prepared based on polyethylene glycol (PEG) materials. PEG is a synthetic material that is nontoxic and inert and, thus, suitable for use in medical products. We evaluated the in vitro biocompatibility tests of the dressings to assess cytotoxicity and irritation, sensitization, pyrogen toxicity, and systemic toxicity following the International Organization for Standardization 10993 standards and the in vivo effects of the hydrogel samples using Coloskin liquid bandages as control samples for potential in wound closure. PMID:29637814
Asadpour-Zeynali, Karim; Saeb, Elhameh
2016-01-01
Three antituberculosis medications are investigated in this work consist of rifampicin, isoniazid and pyrazinamide. The ultra violet (UV) spectra of these compounds are overlapped, thus use of suitable chemometric methods are helpful for simultaneous spectrophotometric determination of them. A generalized version of net analyte signal standard addition method (GNASSAM) was used for determination of three antituberculosis medications as a model system. In generalized net analyte signal standard addition method only one standard solution was prepared for all analytes. This standard solution contains a mixture of all analytes of interest, and the addition of such solution to sample, causes increases in net analyte signal of each analyte which are proportional to the concentrations of analytes in added standards solution. For determination of concentration of each analyte in some synthetic mixtures, the UV spectra of pure analytes and each sample were recorded in the range of 210 nm-550 nm. The standard addition procedure was performed for each sample and the UV spectrum was recorded after each addition and finally the results were analyzed by net analyte signal method. Obtained concentrations show acceptable performance of GNASSAM in these cases. PMID:28243267
Validation of Physics Standardized Test Items
NASA Astrophysics Data System (ADS)
Marshall, Jill
2008-10-01
The Texas Physics Assessment Team (TPAT) examined the Texas Assessment of Knowledge and Skills (TAKS) to determine whether it is a valid indicator of physics preparation for future course work and employment, and of the knowledge and skills needed to act as an informed citizen in a technological society. We categorized science items from the 2003 and 2004 10th and 11th grade TAKS by content area(s) covered, knowledge and skills required to select the correct answer, and overall quality. We also analyzed a 5000 student sample of item-level results from the 2004 11th grade exam using standard statistical methods employed by test developers (factor analysis and Item Response Theory). Triangulation of our results revealed strengths and weaknesses of the different methods of analysis. The TAKS was found to be only weakly indicative of physics preparation and we make recommendations for increasing the validity of standardized physics testing..
Ong, E S; Yong, Y L; Woo, S O
1999-01-01
A simple, rapid, and sensitive method with high sample throughput was developed for determining arsenic in traditional Chinese medicine (TCM) in the form of uncoated tablets, sugar-coated tablets, black pills, capsules, powders, and syrups. The method involves microwave digestion with flow injection-inductively coupled plasma mass spectrometry (FI-ICP-MS). Method precision was 2.7-10.1% (relative standard deviation, n = 6) for different concentrations of arsenic in different TCM samples analyzed by different analysts on different days. Method accuracy was checked with a certified reference material (sea lettuce, Ulva lactuca, BCR CRM 279) for external calibration and by spiking arsenic standard into different TCMs. Recoveries of 89-92% were obtained for the certified reference material and higher than 95% for spiked TCMs. Matrix interference was insignificant for samples analyzed by the method of standard addition. Hence, no correction equation was used in the analysis of arsenic in the samples studied. Sample preparation using microwave digestion gave results that were very similar to those obtained by conventional wet acid digestion using nitric acid.
Bıçakcı, Hazal; Çapar, İsmail Davut; Genç, Selin; İhtiyar, Alperen; Sütçü, Recep
2016-11-01
The first objective was to determine correlation among various experimental and clinical pain measurement procedures. The second objective was to evaluate the influence of rotary instrumentation with continuous irrigation on pain and neuropeptide release levels. Forty patients who had preoperative pain at the levels of 3-8 on the visual analogue scale were included. Gingival crevicular fluid (GCF) samples were collected. Patients were randomly assigned to 2 treatment groups, the standard preparation group and the preparation with continuous irrigation group. Apical fluid samples (AFS) were collected after instrumentation. In the second visit, the patients' pain levels were recorded, and GCF and AFS were obtained. Substance P, calcitonin-gene related peptide (CGRP), interleukin (IL)-1β, and IL-10 levels were analyzed from the GCF and AFS samples. For comparison between groups, the Mann-Whitney test was used (P < .05). In terms of clinical data, no significant difference was detected in the first and second sessions between groups. The IL-10 level obtained from AFS significantly decreased in the second session in both groups (P < .001). Visual analogue scale scores of spontaneous pain correlated with percussion pain positively (r = 0.718, P < .001). CGRP (GCF) (second session) and IL-10 (GCF) (second session) positively correlated with percussion pain (r = 0.425, P < .01) (r = 0.379, P < .05). Rotary preparation with continuous irrigation has not been more effective than the standard preparation method for reducing pain. Because of determination of the correlation between CGRP and IL-10 with percussion pain, these neuropeptides can be used in further studies. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.
Tankiewicz, Maciej; Fenik, Jolanta; Biziuk, Marek
2011-10-30
The intensification of agriculture means that increasing amounts of toxic organic and inorganic compounds are entering the environment. The pesticides generally applied nowadays are regarded as some of the most dangerous contaminants of the environment. Their presence in the environment, especially in water, is hazardous because they cause human beings to become more susceptible to disease. For these reasons, it is essential to monitor pesticide residues in the environment with the aid of all accessible analytical methods. The analysis of samples for the presence of pesticides is problematic, because of the laborious and time-consuming operations involved in preparing samples for analysis, which themselves may be a source of additional contaminations and errors. To date, it has been standard practice to use large quantities of organic solvents in the sample preparation process; but as these solvents are themselves hazardous, solventless and solvent-minimized techniques are coming into use. This paper discusses the most commonly used over the last 15 years sample preparation techniques for monitoring organophosphorus and organonitrogen pesticides residue in water samples. Furthermore, a significant trend in sample preparation, in accordance with the principles of 'Green Chemistry' is the simplification, miniaturization and automation of analytical techniques. In view of this aspect, several novel techniques are being developed in order to reduce the analysis step, increase the sample throughput and to improve the quality and the sensitivity of analytical methods. The paper describes extraction techniques requiring the use of solvents - liquid-liquid extraction (LLE) and its modifications, membrane extraction techniques, hollow fibre-protected two-phase solvent microextraction, liquid phase microextraction based on the solidification of a floating organic drop (LPME-SFO), solid-phase extraction (SPE) and single-drop microextraction (SDME) - as well as solvent-free techniques - solid phase microextraction (SPME) and stir bar sorptive extraction (SBSE). The advantages and drawbacks of these techniques are also discussed, and some solutions to their limitations are proposed. Copyright © 2011 Elsevier B.V. All rights reserved.
Hossain, Mirza Akram; Friciu, Mihaela; Aubin, Sebastien; Leclair, Grégoire
2014-04-15
The stability of penicillin G sodium solutions stored in polyvinyl chloride (PVC) bags or elastomeric pump containers was studied. Test samples were prepared by diluting powdered penicillin G sodium (10 million units/10-mL vial) to solutions of 2,500 or 50,000 units/mL with 0.9% sodium chloride injection or 5% dextrose injection. The preparations were transferred to 250-mL PVC bags and elastomeric pump containers. All samples were prepared in triplicate and stored at 5°C. Chemical stability was measured by a stability-indicating high-performance liquid chromatographic (HPLC) assay and by pH evaluation. Particulate matter was evaluated according to compendial standards using a light-obscuration particle count test. Preparations were visually examined throughout the study. After 21 days of storage, all test samples remained chemically stable, with an HPLC assay recovery value of more than 90% of the initial value. After 28 days, all samples prepared with either diluent and stored in PVC bags, as well as the samples diluted to 2,500 units/mL with sodium chloride injection and stored in elastomeric pump containers, did not meet the recovery acceptance limit. For all test samples, the mean pH consistently decreased during storage, from about 6.4 to about 5.5. Particle counts remained acceptable throughout the study, and no change in appearance was observed. Penicillin G for injection (2,500 and 50,000 units/mL) diluted in 0.9% sodium chloride injection or 5% dextrose injection and stored at 5°C in PVC containers or elastomeric pump containers was physically and chemically stable for a period of at least 21 days.
Schmitt, Christopher J.; Finger, Susan E.
1987-01-01
The influence of sample preparation on measured concentrations of eight elements in the edible tissues of two black basses (Centrarchidae), two catfishes (Ictaluridae), and the black redhorse,Moxostoma duquesnei (Catostomidae) from two rivers in southeastern Missouri contaminated by mining and related activities was investigated. Concentrations of Pb, Cd, Cu, Zn, Fe, Mn, Ba, and Ca were measured in two skinless, boneless samples of axial muscle from individual fish prepared in a clean room. One sample (normally-processed) was removed from each fish with a knife in a manner typically used by investigators to process fish for elemental analysis and presumedly representative of methods employed by anglers when preparing fish for home consumption. A second sample (clean-processed) was then prepared from each normally-processed sample by cutting away all surface material with acid-cleaned instruments under ultraclean conditions. The samples were analyzed as a single group by atomic absorption spectrophotometry. Of the elements studied, only Pb regularly exceeded current guidelines for elemental contaminants in foods. Concentrations were high in black redhorse from contaminated sites, regardless of preparation method; for the other fishes, whether or not Pb guidelines were exceeded depended on preparation technique. Except for Mn and Ca, concentrations of all elements measured were significantly lower in cleanthan in normally-processed tissue samples. Absolute differences in measured concentrations between clean- and normally-processed samples were most evident for Pb and Ba in bass and catfish and for Cd and Zn in redhorse. Regardless of preparation method, concentrations of Pb, Ca, Mn, and Ba in individual fish were closely correlated; samples that were high or low in one of these four elements were correspondingly high or low in the other three. In contrast, correlations between Zn, Fe, and Cd occurred only in normallyprocessed samples, suggesting that these correlations resulted from high concentrations on the surfaces of some samples. Concentrations of Pb and Ba in edible tissues of fish from contaminated sites were highly correlated with Ca content, which was probably determined largely by the amount of tissue other than muscle in the sample because fish muscle contains relatively little Ca. Accordingly, variation within a group of similar samples can be reduced by normalizing Pb and Ba concentrations to a standard Ca concentration. When sample size (N) is large, this can be accomplished statistically by analysis of covariance; whenN is small, molar ratios of [Pb]/[Ca] and [Ba]/[Ca] can be computed. Without such adjustments, unrealistically large Ns are required to yield statistically reliable estimates of Pb concentrations in edible tissues. Investigators should acknowledge that reported concentrations of certain elements are only estimates, and that regardless of the care exercised during the collection, preparation, and analysis of samples, results should be interpreted with the awareness that contamination from external sources may have occurred.
Wan, J B; Lai, C M; Li, S P; Lee, M Y; Kong, L Y; Wang, Y T
2006-04-11
A HPLC and pressurized liquid extraction (PLE) method was developed for simultaneous determination of nine saponins, including notoginsenoside R1, ginsenoside Rg1, Re, Rf, Rb1, Rc, Rb2, Rb3 and Rd in Panax notoginseng. The analysis was performed on C18 column with water-acetonitrile gradient elution and the investigated saponins were authenticated by comparing retention time and mass spectra with their reference compounds. Several methods including PLE, ultrasonication, soxhlet extraction and immersion were used for sample preparation and their extraction efficiency was compared. The results showed that PLE has the highest extraction efficiency and repeatability, which would be valuable on standardization of sample preparation for quality control of Chinese medicines. The developed HPLC and PLE is an effective approach for simultaneously quantitative determination of sapoinins in P. notoginseng, which could be used for quality control of P. notoginseng and its preparations.
Barroso, Gerardo; Chaya, Miguel; Bolaños, Rubén; Rosado, Yadira; García León, Fernando; Ibarrola, Eduardo
2005-05-01
To evaluate sperm recovery and total sperm motility in three different sperm preparation techniques (density gradient, simple washing and swim-up). A total of 290 subjects were randomly evaluated from November 2001 to March 2003. The density gradient method required Isolate (upper and lower layers). Centrifugation was performed at 400 g for 10 minutes and evaluation was done using the Makler counting chamber. The simple washing method included the use of HTF-M complemented with 7.5% of SSS, with centrifugation at 250 g, obtaining at the end 0.5 mL of the sperm sample. The swim-up method required HTF-M complemented with 7.5% of SSS, with an incubation period of 60 minutes at 37 degrees C. The demographic characteristics evaluated through their standard error, 95% ICC, and 50th percentile were similar. The application of multiple comparison tests and analysis of variance showed significant differences between the sperm preparations before and after capacitation. It was observed a superior recovery rate with the density gradient and swim-up methods; nevertheless, the samples used for the simple washing method showed a diminished sperm recovery from the original sample. Sperm preparation techniques have become very useful in male infertility treatments allowing higher sperm recovery and motility rates. The seminal parameters evaluated from the original sperm sample will determine the best sperm preparation technique in those patients who require it.
Potential sources of analytical bias and error in selected trace element data-quality analyses
Paul, Angela P.; Garbarino, John R.; Olsen, Lisa D.; Rosen, Michael R.; Mebane, Christopher A.; Struzeski, Tedmund M.
2016-09-28
Potential sources of analytical bias and error associated with laboratory analyses for selected trace elements where concentrations were greater in filtered samples than in paired unfiltered samples were evaluated by U.S. Geological Survey (USGS) Water Quality Specialists in collaboration with the USGS National Water Quality Laboratory (NWQL) and the Branch of Quality Systems (BQS).Causes for trace-element concentrations in filtered samples to exceed those in associated unfiltered samples have been attributed to variability in analytical measurements, analytical bias, sample contamination either in the field or laboratory, and (or) sample-matrix chemistry. These issues have not only been attributed to data generated by the USGS NWQL but have been observed in data generated by other laboratories. This study continues the evaluation of potential analytical bias and error resulting from matrix chemistry and instrument variability by evaluating the performance of seven selected trace elements in paired filtered and unfiltered surface-water and groundwater samples collected from 23 sampling sites of varying chemistries from six States, matrix spike recoveries, and standard reference materials.Filtered and unfiltered samples have been routinely analyzed on separate inductively coupled plasma-mass spectrometry instruments. Unfiltered samples are treated with hydrochloric acid (HCl) during an in-bottle digestion procedure; filtered samples are not routinely treated with HCl as part of the laboratory analytical procedure. To evaluate the influence of HCl on different sample matrices, an aliquot of the filtered samples was treated with HCl. The addition of HCl did little to differentiate the analytical results between filtered samples treated with HCl from those samples left untreated; however, there was a small, but noticeable, decrease in the number of instances where a particular trace-element concentration was greater in a filtered sample than in the associated unfiltered sample for all trace elements except selenium. Accounting for the small dilution effect (2 percent) from the addition of HCl, as required for the in-bottle digestion procedure for unfiltered samples, may be one step toward decreasing the number of instances where trace-element concentrations are greater in filtered samples than in paired unfiltered samples.The laboratory analyses of arsenic, cadmium, lead, and zinc did not appear to be influenced by instrument biases. These trace elements showed similar results on both instruments used to analyze filtered and unfiltered samples. The results for aluminum and molybdenum tended to be higher on the instrument designated to analyze unfiltered samples; the results for selenium tended to be lower. The matrices used to prepare calibration standards were different for the two instruments. The instrument designated for the analysis of unfiltered samples was calibrated using standards prepared in a nitric:hydrochloric acid (HNO3:HCl) matrix. The instrument designated for the analysis of filtered samples was calibrated using standards prepared in a matrix acidified only with HNO3. Matrix chemistry may have influenced the responses of aluminum, molybdenum, and selenium on the two instruments. The best analytical practice is to calibrate instruments using calibration standards prepared in matrices that reasonably match those of the samples being analyzed.Filtered and unfiltered samples were spiked over a range of trace-element concentrations from less than 1 to 58 times ambient concentrations. The greater the magnitude of the trace-element spike concentration relative to the ambient concentration, the greater the likelihood spike recoveries will be within data control guidelines (80–120 percent). Greater variability in spike recoveries occurred when trace elements were spiked at concentrations less than 10 times the ambient concentration. Spike recoveries that were considerably lower than 90 percent often were associated with spiked concentrations substantially lower than what was present in the ambient sample. Because the main purpose of spiking natural water samples with known quantities of a particular analyte is to assess possible matrix effects on analytical results, the results of this study stress the importance of spiking samples at concentrations that are reasonably close to what is expected but sufficiently high to exceed analytical variability. Generally, differences in spike recovery results between paired filtered and unfiltered samples were minimal when samples were analyzed on the same instrument.Analytical results for trace-element concentrations in ambient filtered and unfiltered samples greater than 10 and 40 μg/L, respectively, were within the data-quality objective for precision of ±25 percent. Ambient trace-element concentrations in filtered samples greater than the long-term method detection limits but less than 10 μg/L failed to meet the data-quality objective for precision for at least one trace element in about 54 percent of the samples. Similarly, trace-element concentrations in unfiltered samples greater than the long-term method detection limits but less than 40 μg/L failed to meet this data-quality objective for at least one trace-element analysis in about 58 percent of the samples. Although, aluminum and zinc were particularly problematic, limited re-analyses of filtered and unfiltered samples appeared to improve otherwise failed analytical precision.The evaluation of analytical bias using standard reference materials indicate a slight low bias for results for arsenic, cadmium, selenium, and zinc. Aluminum and molybdenum show signs of high bias. There was no observed bias, as determined using the standard reference materials, during the analysis of lead.
Selective preparation of hard dental tissue: classical and laser treatments comparison
NASA Astrophysics Data System (ADS)
Dostálova, Tat'jana; Jelínkova, Helena; Němec, Michal; Koranda, Petr; Miyagi, Mitsunobu; Iwai, Katsumasa; Shi, Yi-Wei; Matsuura, Yuji
2006-02-01
For the purpose of micro-selective preparation which is part of the modern dentistry four various methods were examined: ablation by Er:YAG laser radiation (free-running or Q-switching regime), preparation of tissues by ultrasonic round ball tip, and by the classical dental drilling machine using diamond round bur. In the case of Er:YAG laser application the interaction energy 40 mJ in pulse of 200 us yielding to the interaction intensity 62 kW/cm2, and 20 mJ in pulse of 100 ns yielding to the interaction intensity 62 MW/cm2 was used for the case of free running, and Q-switch regime, respectively. For comparisson with the classical methods the ultrasound preparation tip (Sonixflex cariex TC, D - Sonicsys micro) and dental driller together with usual preparation burrs and standard handpiece were used. For the interaction experiment the samples of extracted human teeth and ebony cut into longitudinal sections and polished were used. The thickness of the prepared samples ranged from 5 to 7 mm. The methods were compared from the point of prepared cavity shape (SEM), inner surface, and possibility of selective removal of carries. The composite filling material was used to reconstruct the cavities. The dye penetrating analysis was performed.
Lutka, Anna; Maruszewska, Małgorzata
2011-01-01
It were established and validated the conditions of voltammetric determination of copper in pharmaceutical preparations. The three selected preparations: Zincuprim (A), Wapń, cynk, miedź z wit. C (B), Vigor complete (V) contained different salts and different quantity of copper (II) and increasing number of accompanied ingredients. For the purpose to transfer copper into solution, the samples of powdered tablets of the first and second preparation were undergone extraction and of the third the mineralization procedures. The concentration of copper in solution was determined by differential pulse voltammetry (DP) using comparison with standard technique. In the validation process, the selectivity, accuracy, precision and linearity of DP determination of copper in three preparations were estimated. Copper was determined within the concentration range of 1-9 ppm (1-9 microg/mL): the mean recoveries approached 102% (A), 100% (B), 102% (V); the relative standard deviations of determinations (RSD) were 0.79-1.59% (A), 0.62-0.85% (B) and 1.68-2.28% (V), respectively. The mean recoveries and the RSDs of determination satisfied the requirements for the analyte concentration at the level 1-10 ppm. The statistical verification confirmed that the tested voltammetric method is suitable for determination of copper in pharmaceutical preparation.
NASA Technical Reports Server (NTRS)
Otterson, D. A.; Seng, G. T.
1984-01-01
A new high-performance liquid chromatographic (HPLC) method for group-type analysis of middistillate fuels is described. It uses a refractive index detector and standards that are prepared by reacting a portion of the fuel sample with sulfuric acid. A complete analysis of a middistillate fuel for saturates and aromatics (including the preparation of the standard) requires about 15 min if standards for several fuels are prepared simultaneously. From model fuel studies, the method was found to be accurate to within 0.4 vol% saturates or aromatics, and provides a precision of + or - 0.4 vol%. Olefin determinations require an additional 15 min of analysis time. However, this determination is needed only for those fuels displaying a significant olefin response at 200 nm (obtained routinely during the saturated/aromatics analysis procedure). The olefin determination uses the responses of the olefins and the corresponding saturates, as well as the average value of their refractive index sensitivity ratios (1.1). Studied indicated that, although the relative error in the olefins result could reach 10 percent by using this average sensitivity ratio, it was 5 percent for the fuels used in this study. Olefin concentrations as low as 0.1 vol% have been determined using this method.
Evidence of Cultural Competence within Teacher Performance Assessments
ERIC Educational Resources Information Center
Dee, Amy Lynn
2012-01-01
Professional integrity and changing demographics in the public school system in the United States coupled with standards for teacher preparation require that preservice teachers possess knowledge, skills, and dispositions necessary to work with diverse populations. Using the Teacher Work Sample, a plan for instruction serving as a teacher…
Flight Instructor: Airplane. Written Test Guide.
ERIC Educational Resources Information Center
Federal Aviation Administration (DOT), Washington, DC. Flight Standards Service.
The Flight Standards Service of the Federal Aviation Administration developed the guide to assist applicants who are preparing for the Flight Instructor Certificate with Airplane Rating. The guide contains comprehensive study outlines and a list of recommended study materials and tells how to obtain those publications. It also includes sample test…
NASA Astrophysics Data System (ADS)
Tang, Xiaoxing; Qian, Yuan; Guo, Yanchuan; Wei, Nannan; Li, Yulan; Yao, Jian; Wang, Guanghua; Ma, Jifei; Liu, Wei
2017-12-01
A novel method has been improved for analyzing atmospheric pollutant metals (Be, Mn, Fe, Co, Ni, Cu, Zn, Se, Sr, Cd, and Pb) by laser ablation inductively coupled plasma mass spectrometry. In this method, solid standards are prepared by depositing droplets of aqueous standard solutions on the surface of a membrane filter, which is the same type as used for collecting atmospheric pollutant metals. Laser parameters were optimized, and ablation behaviors of the filter discs were studied. The mode of radial line scans across the filter disc was a representative ablation strategy and can avoid error from the inhomogeneous filter standards and marginal effect of the filter disc. Pt, as the internal standard, greatly improved the correlation coefficient of the calibration curve. The developed method provides low detection limits, from 0.01 ng m- 3 for Be and Co to 1.92 ng m- 3 for Fe. It was successfully applied for the determination of atmospheric pollutant metals collected in Lhasa, China. The analytical results showed good agreement with those obtained by conventional liquid analysis. In contrast to the conventional acid digestion procedure, the novel method not only greatly reduces sample preparation and shortens the analysis time but also provides a possible means for studying the spatial distribution of atmospheric filter samples.
Sample preparation for total reflection X-ray fluorescence analysis using resist pattern technique
NASA Astrophysics Data System (ADS)
Tsuji, K.; Yomogita, N.; Konyuba, Y.
2018-06-01
A circular resist pattern layer with a diameter of 9 mm was prepared on a glass substrate (26 mm × 76 mm; 1.5 mm thick) for total reflection X-ray fluorescence (TXRF) analysis. The parallel cross pattern was designed with a wall thickness of 10 μm, an interval of 20 μm, and a height of 1.4 or 0.8 μm. This additional resist layer did not significantly increase background intensity on the XRF peaks in TXRF spectra. Dotted residue was obtained from a standard solution (10 μL) containing Ti, Cr, Ni, Pb, and Ga, each at a final concentration of 10 ppm, on a normal glass substrate with a silicone coating layer. The height of the residue was more than 100 μm, where self-absorption in the large residue affected TXRF quantification (intensity relative standard deviation (RSD): 12-20%). In contrast, from a droplet composed of a small volume of solution dropped and cast on the resist pattern structure, the obtained residue was not completely film but a film-like residue with a thickness less than 1 μm, where self-absorption was not a serious problem. In the end, this sample preparation was demonstrated to improve TXRF quantification (intensity RSD: 2-4%).
Xu, Tielong; Zhong, Daibin; Tang, Linhua; Chang, Xuelian; Fu, Fengyang; Yan, Guiyun; Zheng, Bin
2014-01-28
Insecticide resistance monitoring in malaria mosquitoes is essential for guiding the rational use of insecticides in vector control programs. Resistance bioassay is the first step for insecticide monitoring and it lays an important foundation for molecular examination of resistance mechanisms. In the literature, various mosquito sample collection and preparation methods have been used, but how mosquito sample collection and preparation methods affect insecticide susceptibility bioassay results is largely unknown. The objectives of this study were to determine whether mosquito sample collection and preparation methods affected bioassay results, which may cause incorrect classification of mosquito resistance status. The study was conducted in Anopheles sinensis mosquitoes in two study sites in central China. Three mosquito sample collection and preparation methods were compared for insecticide susceptibility, kdr frequencies and metabolic enzyme activities: 1) adult mosquitoes collected from the field; 2) F1 adults from field collected, blood-fed mosquitoes; and 3) adult mosquitoes reared from field collected larvae. Mosquito sample collection and preparation methods significantly affected mortality rates in the standard WHO tube resistance bioassay. Mortality rate of field-collected female adults was 10-15% higher than in mosquitoes reared from field-collected larvae and F1 adults from field collected blood-fed females. This pattern was consistent in mosquitoes from the two study sites. High kdr mutation frequency (85-95%) with L1014F allele as the predominant mutation was found in our study populations. Field-collected female adults consistently exhibited the highest monooxygenase and GST activities. The higher mortality rate observed in the field-collected female mosquitoes may have been caused by a mixture of mosquitoes of different ages, as older mosquitoes were more susceptible to deltamethrin than younger mosquitoes. Female adults reared from field-collected larvae in resistance bioassays are recommended to minimize the effect of confounding factors such as mosquito age and blood feeding status so that more reliable and reproducible mortality may be obtained.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jackson, L.L.; Engleman, E.E.; Peard, J.L.
Sulfur was determined in plants and lichens by combustion of the sample and infrared detection of evolved sulfur dioxide using an automated sulfur analyzer. Vanadium pentaoxide was used as a combustion accelerator. Pelletization of the sample prior to combustion was not found to be advantageous. Washing studies showed that leaching of sulfur was not a major factor in the sample preparation. The combustion-IR analysis usually gave higher sulfur content than the turbidimetric analysis as well as shorter analysis time. Relative standard deviations of less than 7% were obtained by the combustion-IR technique when sulfur levels in plant material range frommore » 0.05 to 0.70%. Determination of sulfur in National Bureau of Standards botanical reference materials showed good agreement between the combustion-IR technique and other instrumental procedures. Seven NBS botanical reference materials were analyzed.« less
Hondrogiannis, Ellen; Rotta, Kathryn; Zapf, Charles M
2013-03-01
Sixteen elements found in 37 vanilla samples from Madagascar, Uganda, India, Indonesia (all Vanilla planifolia species), and Papa New Guinea (Vanilla tahitensis species) were measured by wavelength dispersive X-ray fluorescence (WDXRF) spectroscopy for the purpose of determining the elemental concentrations to discriminate among the origins. Pellets were prepared of the samples and elemental concentrations were calculated based on calibration curves created using 4 Natl. Inst. of Standards and Technology (NIST) standards. Discriminant analysis was used to successfully classify the vanilla samples by their species and their geographical region. Our method allows for higher throughput in the rapid screening of vanilla samples in less time than analytical methods currently available. Wavelength dispersive X-ray fluorescence spectroscopy and discriminant function analysis were used to classify vanilla from different origins resulting in a model that could potentially serve to rapidly validate these samples before purchasing from a producer. © 2013 Institute of Food Technologists®
Leung, Yu Hang; Guo, Mu Yao; Ma, Angel P Y; Ng, Alan M C; Djurišić, Aleksandra B; Degger, Natalie; Leung, Frederick C C
2017-07-01
We investigated transmission electron microscopy artifacts obtained using standard sample preparation protocols applied to the investigation of Escherichia coli cells exposed to common nanomaterials, such as TiO 2 , Ag, ZnO, and MgO. While the common protocols for some nanomaterials result only in known issues of nanomaterial-independent generation of anomalous deposits due to fixation and staining, for others, there are reactions between the nanomaterial and chemicals used for post-fixation or staining. Only in the case of TiO 2 do we observe only the known issues of nanomaterial-independent generation of anomalous deposits due to exceptional chemical stability of this material. For the other three nanomaterials, different artifacts are observed. For each of those, we identify causes of the observed problems and suggest alternative sample preparation protocols to avoid artifacts arising from the sample preparation, which is essential for correct interpretation of the obtained images and drawing correct conclusions on cell-nanomaterial interactions. Finally, we propose modified sample preparation and characterization protocols for comprehensive and conclusive investigations of nanomaterial-cell interactions using electron microscopy and for obtaining clear and unambiguous revelation whether the nanomaterials studied penetrate the cells or accumulate at the cell membranes. In only the case of MgO and ZnO, the unambiguous presence of Zn and Mg could be observed inside the cells.
Xue, Shu-Wen; Li, Jing; Xu, Li
2017-05-01
Magnetic melamine-formaldehyde resin was prepared via water-in-oil emulsification approach by entrapping Fe 3 O 4 magnetic nanoparticles as the core. The preparation of the magnetic resin was optimized by investigating the amount of polyethylene glycol 20000 and Fe 3 O 4 nanoparticles, the concentration of the catalyst (hydrochloric acid), as well as the mechanical stirring rate. The prepared material was characteristic of excellent anion-exchange capacity, good water wettability, and proper magnetism. Its application was demonstrated by magnetic solid-phase extraction of nonsteroidal anti-inflammatory drugs coupled to high performance liquid chromatography-UV analysis. Under the optimal conditions, the proposed method showed broad linear range of 1-5000 ng mL -1 of milk and urine samples, satisfactory reproducibility with intra-day and inter-day relative standard deviations less than 12.4% and 9.7%, respectively, and low limits of detection of 0.2 ng mL -1 for the studied nonsteroidal anti-inflammatory drugs. The developed method was successfully used for the determination of the nonsteroidal anti-inflammatory drugs in spiked urine and milk samples. The magnetic melamine-formaldehyde resin was promising for the sample pretreatment of acidic analytes via anion-exchange interaction with convenient operation from complex sample matrix. Graphical abstract Magnetic solid-phase extraction based on melamine-formaldehyde resin.
Zou, Lili; Shen, Kaini; Zhong, Dingrong; Zhou, Daobin; Sun, Wei; Li, Jian
2015-01-01
Laser microdissection followed by mass spectrometry has been successfully used for amyloid typing. However, sample contamination can interfere with proteomic analysis, and overnight digestion limits the analytical throughput. Moreover, current quantitative analysis methods are based on the spectrum count, which ignores differences in protein length and may lead to misdiagnoses. Here, we developed a microwave-assisted filter-aided sample preparation (maFASP) method that can efficiently remove contaminants with a 10-kDa cutoff ultrafiltration unit and can accelerate the digestion process with the assistance of a microwave. Additionally, two parameters (P- and D-scores) based on the exponentially modified protein abundance index were developed to define the existence of amyloid deposits and those causative proteins with the greatest abundance. Using our protocol, twenty cases of systemic amyloidosis that were well-typed according to clinical diagnostic standards (training group) and another twenty-four cases without subtype diagnoses (validation group) were analyzed. Using this approach, sample preparation could be completed within four hours. We successfully subtyped 100% of the cases in the training group, and the diagnostic success rate in the validation group was 91.7%. This maFASP-aided proteomic protocol represents an efficient approach for amyloid diagnosis and subtyping, particularly for serum-contaminated samples. PMID:25984759
A comparative study of ChIP-seq sequencing library preparation methods.
Sundaram, Arvind Y M; Hughes, Timothy; Biondi, Shea; Bolduc, Nathalie; Bowman, Sarah K; Camilli, Andrew; Chew, Yap C; Couture, Catherine; Farmer, Andrew; Jerome, John P; Lazinski, David W; McUsic, Andrew; Peng, Xu; Shazand, Kamran; Xu, Feng; Lyle, Robert; Gilfillan, Gregor D
2016-10-21
ChIP-seq is the primary technique used to investigate genome-wide protein-DNA interactions. As part of this procedure, immunoprecipitated DNA must undergo "library preparation" to enable subsequent high-throughput sequencing. To facilitate the analysis of biopsy samples and rare cell populations, there has been a recent proliferation of methods allowing sequencing library preparation from low-input DNA amounts. However, little information exists on the relative merits, performance, comparability and biases inherent to these procedures. Notably, recently developed single-cell ChIP procedures employing microfluidics must also employ library preparation reagents to allow downstream sequencing. In this study, seven methods designed for low-input DNA/ChIP-seq sample preparation (Accel-NGS® 2S, Bowman-method, HTML-PCR, SeqPlex™, DNA SMART™, TELP and ThruPLEX®) were performed on five replicates of 1 ng and 0.1 ng input H3K4me3 ChIP material, and compared to a "gold standard" reference PCR-free dataset. The performance of each method was examined for the prevalence of unmappable reads, amplification-derived duplicate reads, reproducibility, and for the sensitivity and specificity of peak calling. We identified consistent high performance in a subset of the tested reagents, which should aid researchers in choosing the most appropriate reagents for their studies. Furthermore, we expect this work to drive future advances by identifying and encouraging use of the most promising methods and reagents. The results may also aid judgements on how comparable are existing datasets that have been prepared with different sample library preparation reagents.
Imaging MALDI MS of Dosed Brain Tissues Utilizing an Alternative Analyte Pre-extraction Approach
NASA Astrophysics Data System (ADS)
Quiason, Cristine M.; Shahidi-Latham, Sheerin K.
2015-06-01
Matrix-assisted laser desorption ionization (MALDI) imaging mass spectrometry has been adopted in the pharmaceutical industry as a useful tool to detect xenobiotic distribution within tissues. A unique sample preparation approach for MALDI imaging has been described here for the extraction and detection of cobimetinib and clozapine, which were previously undetectable in mouse and rat brain using a single matrix application step. Employing a combination of a buffer wash and a cyclohexane pre-extraction step prior to standard matrix application, the xenobiotics were successfully extracted and detected with an 8 to 20-fold gain in sensitivity. This alternative approach for sample preparation could serve as an advantageous option when encountering difficult to detect analytes.
van Hoeven, Karen H.; Dale, Connie; Foster, Phil; Body, Barbara
2008-01-01
Accurate determination of the concentrations of immunoglobulin G (IgG) antibody to tetanus toxoid is important in order to evaluate the immunogenicity of tetanus toxoid vaccines, determine immune competence in individual patients, and measure the prevalence of immunity in populations. The performance of three commercially available enzyme-linked immunosorbent assays (ELISAs) for IgG antibodies to tetanus toxoid were evaluated. Serially diluted NIBSC 76/589 and TE-3 human tetanus IgG immunoglobulin international reference standards were analyzed in quadruplicate using ELISAs manufactured by The Binding Site, Inc. (VaccZyme); Scimedx; and Euroimmun. In addition, IgG antibodies to tetanus toxoid were measured in 83 deidentified serum specimens using each manufacturer's ELISA. Each ELISA provided linear results when evaluated with the reference preparations. The Binding Site ELISA provided results that closely corresponded to the reference preparations (y = 1.09x − 0.08), whereas the Scimedx ELISA gave results that were consistently lower (y = 0.21x − 0.07) and the Euroimmun ELISA gave results that were consistently higher (y = 1.5x + 0.30) than the reference preparation concentrations. Using the recommended cutoff for each ELISA (<0.10 IU/ml), the overall agreement of all of the ELISA methods was 78%. Three of eighty-three (3.6%) human serum samples demonstrated inadequate immunity with all three assays. The Binding Site ELISA yielded nonprotective antibody concentrations in only these 3 samples, whereas 19 samples (22.9%) according to the Scimedx ELISA and 6 samples (7.2%) according to the Euroimmun ELISA demonstrated nonprotective concentrations. The performance characteristics of ELISAs for tetanus immunoglobulin titers were manufacturer dependent, and the differences translated into important disparities in reported results. PMID:18845832
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grote, R.A.
1991-05-01
The report is a recommended operating procedure (ROP), prepared for use in research activities conducted by EPA's Air and Energy Engineering Research Laboratory (AEERL). The method described is applicable to the stack sampling of flue gas from a rotary kiln and to associated equipment of AEERL's Combustion Research Branch. It has been the standard method of sampling kiln flue gas due to the transient nature of the puff development and its capability to sample the maximum volume over the shortest time period. ROPs describe non-routine or experimental research operations where some judgment in application may be warranted. ROPs may notmore » be applicable to activities conducted by other research groups, and should not be used in place of standard operating procedures. Use of ROPs must be accompanied by an understanding of the purpose and scope. Questions should be directed to the author.« less
Thurman, G. B.; Strong, D. M.; Ahmed, A.; Green, S. S.; Sell, K. W.; Hartzman, R. J.; Bach, F. H.
1973-01-01
Use of lymphocyte cultures for in vitro studies such as pretransplant histocompatibility testing has established the need for standardization of this technique. A microculture technique has been developed that has facilitated the culturing of lymphocytes and increased the quantity of cultures feasible, while lowering the variation between replicate samples. Cultures were prepared for determination of tritiated thymidine incorporation using a Multiple Automated Sample Harvester (MASH). Using this system, the parameters that influence the in vitro responsiveness of human lymphocytes to allogeneic lymphocytes have been investigated. PMID:4271568
Flynn, Theodore M.; Koval, Jason C.; Greenwald, Stephanie M.; Owens, Sarah M.; Kemner, Kenneth M.; Antonopoulos, Dionysios A.
2017-01-01
We present DNA sequence data in FASTA-formatted files from aerobic environmental microcosms inoculated with a sole carbon source. DNA sequences are of 16S rRNA genes present in DNA extracted from each microcosm along with the environmental samples (soil, water) used to inoculate them. These samples were sequenced using the Illumina MiSeq platform at the Environmental Sample Preparation and Sequencing Facility at Argonne National Laboratory. This data is compatible with standard microbiome analysis pipelines (e.g., QIIME, mothur, etc.).
Orr, Elizabeth M J; Moscovitch, David A
2014-01-01
Video feedback (VF) interventions effectively reduce social anxiety symptoms and negative self-perception, particularly when they are preceded by cognitive preparation (CP) and followed by cognitive review. In the current study, we re-examined data from a study on the efficacy of a novel VF intervention for individuals high in social anxiety to test the hypothesis that physical appearance anxiety would moderate the effects of VF. Data were analyzed from 68 socially anxious participants who performed an initial public speech, and were randomly assigned to an Elaborated VF condition (VF plus cognitive preparation and cognitive review), a Standard VF condition (VF plus cognitive preparation) or a No VF condition (exposure alone), and then performed a second speech. As hypothesized, when appearance concerns were low, both participants who received Elaborated and Standard VF were significantly less anxious during speech 2 than those in the No VF condition. However, when levels of appearance concern were high, neither Elaborated nor Standard VF reduced anxiety levels during speech 2 beyond the No VF condition. Results from our analog sample suggest the importance of tailoring treatment protocols to accommodate the idiosyncratic concerns of socially anxious patients.
Muirhead, K A; Wallace, P K; Schmitt, T C; Frescatore, R L; Franco, J A; Horan, P K
1986-01-01
As the diagnostic utility of lymphocyte subset analysis has been recognized in the clinical research laboratory, a wide variety of reagents and cell preparation, staining and analysis methods have also been described. Methods that are perfectly suitable for analysis of smaller sample numbers in the biological or clinical research setting are not always appropriate and/or applicable in the setting of a high volume clinical reference laboratory. We describe here some of the specific considerations involved in choosing a method for flow cytometric analysis which minimizes sample preparation and data analysis time while maximizing sample stability, viability, and reproducibility. Monoclonal T- and B-cell reagents from three manufacturers were found to give equivalent results for a reference population of healthy individuals. This was true whether direct or indirect immunofluorescence staining was used and whether cells were prepared by Ficoll-Hypaque fractionation (FH) or by lysis of whole blood. When B cells were enumerated using a polyclonal anti-immunoglobulin reagent, less cytophilic immunoglobulin staining was present after lysis than after FH preparation. However, both preparation methods required additional incubation at 37 degrees C to obtain results concordant with monoclonal B-cell reagents. Standard reagents were chosen on the basis of maximum positive/negative separation and the availability of appropriate negative controls. The effects of collection medium and storage conditions on sample stability and reproducibility of subset analysis were also assessed. Specimens collected in heparin and stored at room temperature in buffered medium gave reproducible results for 3 days after specimen collection, using either FH or lysis as the preparation method. General strategies for instrument optimization, quality control, and biohazard containment are also discussed.
Gravimetric method for the determination of diclofenac in pharmaceutical preparations.
Tubino, Matthieu; De Souza, Rafael L
2005-01-01
A gravimetric method for the determination of diclofenac in pharmaceutical preparations was developed. Diclofenac is precipitated from aqueous solution with copper(II) acetate in pH 5.3 (acetic acid/acetate buffer). Sample aliquots had approximately the same quantity of the drug content in tablets (50 mg) or in ampules (75 mg). The observed standard deviation was about +/- 2 mg; therefore, the relative standard deviation (RSD) was approximately 4% for tablet and 3% for ampule preparations. The results were compared with those obtained with the liquid chromatography method recommended in the United States Pharmacopoeia using the statistical Student's t-test. Complete agreement was observed. It is possible to obtain more precise results using higher aliquots, for example 200 mg, in which case the RSD falls to 1%. This gravimetric method, contrary to what is expected for this kind of procedure, is relatively fast and simple to perform. The main advantage is the absolute character of the gravimetric analysis.
Koren, Lee; Ng, Ella S M; Soma, Kiran K; Wynne-Edwards, Katherine E
2012-01-01
Blood samples from wild mammals and birds are often limited in volume, allowing researchers to quantify only one or two steroids from a single sample by immunoassays. In addition, wildlife serum or plasma samples are often lipemic, necessitating stringent sample preparation. Here, we validated sample preparation for simultaneous liquid chromatography--tandem mass spectrometry (LC-MS/MS) quantitation of cortisol, corticosterone, 11-deoxycortisol, dehydroepiandrosterone (DHEA), 17β-estradiol, progesterone, 17α-hydroxyprogesterone and testosterone from diverse mammalian (7 species) and avian (5 species) samples. Using 100 µL of serum or plasma, we quantified (signal-to-noise (S/N) ratio ≥ 10) 4-7 steroids depending on the species and sample, without derivatization. Steroids were extracted from serum or plasma using automated solid-phase extraction where samples were loaded onto C18 columns, washed with water and hexane, and then eluted with ethyl acetate. Quantitation by LC-MS/MS was done in positive ion, multiple reaction-monitoring (MRM) mode with an atmospheric pressure chemical ionization (APCI) source and heated nebulizer (500°C). Deuterated steroids served as internal standards and run time was 15 minutes. Extraction recoveries were 87-101% for the 8 analytes, and all intra- and inter-run CVs were ≤ 8.25%. This quantitation method yields good recoveries with variable lipid-content samples, avoids antibody cross-reactivity issues, and delivers results for multiple steroids. Thus, this method can enrich datasets by providing simultaneous quantitation of multiple steroids, and allow researchers to reimagine the hypotheses that could be tested with their volume-limited, lipemic, wildlife samples.
Do placebo based validation standards mimic real batch products behaviour? Case studies.
Bouabidi, A; Talbi, M; Bouklouze, A; El Karbane, M; Bourichi, H; El Guezzar, M; Ziemons, E; Hubert, Ph; Rozet, E
2011-06-01
Analytical methods validation is a mandatory step to evaluate the ability of developed methods to provide accurate results for their routine application. Validation usually involves validation standards or quality control samples that are prepared in placebo or reconstituted matrix made of a mixture of all the ingredients composing the drug product except the active substance or the analyte under investigation. However, one of the main concerns that can be made with this approach is that it may lack an important source of variability that come from the manufacturing process. The question that remains at the end of the validation step is about the transferability of the quantitative performance from validation standards to real authentic drug product samples. In this work, this topic is investigated through three case studies. Three analytical methods were validated using the commonly spiked placebo validation standards at several concentration levels as well as using samples coming from authentic batch samples (tablets and syrups). The results showed that, depending on the type of response function used as calibration curve, there were various degrees of differences in the results accuracy obtained with the two types of samples. Nonetheless the use of spiked placebo validation standards was showed to mimic relatively well the quantitative behaviour of the analytical methods with authentic batch samples. Adding these authentic batch samples into the validation design may help the analyst to select and confirm the most fit for purpose calibration curve and thus increase the accuracy and reliability of the results generated by the method in routine application. Copyright © 2011 Elsevier B.V. All rights reserved.
Criado-García, Laura; Garrido-Delgado, Rocío; Arce, Lourdes; Valcárcel, Miguel
2013-07-15
An UV-Ion Mobility Spectrometer is a simple, rapid, inexpensive instrument widely used in environmental analysis among other fields. The advantageous features of its underlying technology can be of great help towards developing reliable, economical methods for determining gaseous compounds from gaseous, liquid and solid samples. Developing an effective method using UV-Ion Mobility Spectrometry (UV-IMS) to determine volatile analytes entails using appropriate gaseous standards for calibrating the spectrometer. In this work, two home-made sample introduction systems (SISs) and a commercial gas generator were used to obtain such gaseous standards. The first home-made SIS used was a static head-space to measure compounds present in liquid samples and the other home-made system was an exponential dilution set-up to measure compounds present in gaseous samples. Gaseous compounds generated by each method were determined on-line by UV-IMS. Target analytes chosen for this comparative study were ethanol, acetone, benzene, toluene, ethylbenzene and xylene isomers. The different alternatives were acceptable in terms of sensitivity, precision and selectivity. Copyright © 2013 Elsevier B.V. All rights reserved.
Crill, Catherine M; Hak, Emily B; Robinson, Lawrence A; Helms, Richard A
2010-06-01
Microbial contamination associated with different methods of neonatal intravenous fat emulsion (IVFE) preparation and delivery was evaluated. Sterility testing was performed on IVFE dispensed via three different methods: (1) in the original container (n = 60), (2) repackaged into a syringe (n = 90), and (3) drawdown of the original container (n = 60). At the end of each infusion (24 hours for methods 1 and 3, 12 hours for method 2), a sample of the IVFE was withdrawn from the container using a sterile syringe in an International Organization for Standardization class 5 hood and sent to the hospital microbiology laboratory, where the samples were introduced into blood culture bottles and incubated for five days. Each sample was then subcultured on a blood agar plate with olive oil and left for an additional two days in a carbon dioxide incubator to assess for Malassezia furfur. None of the samples from the original containers showed bacterial or fungal growth. Three of the samples from syringes had bacterial growth (two samples contained coagulase-negative staphylococcus and one contained both Klebsiella oxytoca and Citrobacter freundii), yielding a contamination rate of 3.3%. The number of contaminated samples did not significantly differ among the three preparation methods (p = 0.13). Repackaging IVFE into sterile syringes resulted in bacterial contamination and should be avoided in clinical practice. IVFE samples obtained using the drawdown procedure under sterile conditions for infusion over 24 hours revealed no microbial contamination.
Simundic, A M; Cornes, M; Grankvist, K; Lippi, G; Nybo, M
2014-05-15
Standardized protocols for patient preparation for laboratory testing are currently lacking. Moreover, a great heterogeneity exists in the definitions of "fasting" currently being used among healthcare workers and in the literature. Marked metabolic and hormonal changes occur after food ingestion, mainly due to the absorption of fluids, lipids, proteins, carbohydrates and other food constituents. This postprandial response varies markedly in response to numerous factors, such as eating behavior, food composition, fasting duration, time of the day, chronic and acute smoking, coffee and alcohol consumption. It is therefore crucial to minimize the total variability by controlling as many of these modifying factors as possible. Control of the abovementioned effects on postprandial response can only be achieved by standardizing the way patients are prepared for laboratory testing, i.e. by defining the fasting duration, as well as what is and what is not allowed (e.g., coffee, tea, smoking, water) during the period of fasting prior to sample collection. The aim of this article is to describe the range of effects of different approaches to fasting on laboratory tests, and to provide a framework for the harmonization of definitions for fasting requirements for laboratory tests. Copyright © 2013 Elsevier B.V. All rights reserved.
Lichte, F.E.; Meier, A.L.; Crock, J.G.
1987-01-01
A method of analysis of geological materials for the determination of the rare-earth elements using the Inductively coupled plasma mass spectrometric technique (ICP-MS) has been developed. Instrumental parameters and factors affecting analytical results have been first studied and then optimized. Samples are analyzed directly following an acid digestion, without the need for separation or preconcentration with limits of detection of 2-11 ng/g, precision of ?? 2.5% relative standard deviation, and accuracy comparable to inductively coupled plasma emission spectrometry and instrumental neutron activation analysis. A commercially available ICP-MS instrument is used with modifications to the sample introduction system, torch, and sampler orifice to reduce the effects of high salt content of sample solutions prepared from geologic materials. Corrections for isobaric interferences from oxide ions and other diatomic and triatomic ions are made mathematically. Special internal standard procedures are used to compensate for drift in metahmetal oxide ratios and sensitivity. Reference standard values are used to verify the accuracy and utility of the method.
Microbiological investigation of halal butchery products and butchers' premises.
Little, C; Gillespie, I; de Louvois, J; Mitchell, R
1999-06-01
Halal butchers' premises were investigated as they had not been represented in a recent study of butchery products and butchers' premises conducted by the Local Authorities Coordinating Body on Food and Trading Standards and the PHLS. This study examined 183 raw prepared meats and 212 environmental samples from 105 halal butcher premises. Only raw meats were prepared on 97 of the premises visited; and the types of meat prepared on the remaining eight premises was not specified. Four halal butchers sold cooked meats prepared elsewhere. Salmonella spp. and Campylobacter spp. were detected in 12 (7%) and 52 (28%) of the 183 raw meat products, respectively. Five raw prepared meats (3%) contained both salmonella and campylobacter. Vero cytotoxin producing Escherichia coli O157 was isolated from a raw meat product that also contained campylobacter. No cooked meat products were available for collection. The physical separation of raw and unwrapped cooked meat products in premises that prepared raw and sold cooked meats was not recorded. Apron cloths were the most heavily contaminated environmental samples examined; hygiene indicator microorganisms indicated an increased risk of cross contamination. Managers in 85 premises had received no food hygiene training and 88 premises had no hazard analysis system in place. Improvements are needed to reduce the risk of cross contamination.
Wang, Lei; Qiang, Wei; Li, Ying; Cheng, Zeneng; Xie, Mengmeng
2017-09-01
Plasma samples were conventionally stored at freezing conditions until the time of detection. Such a technique, when carried out over an extended period, is energy consuming; in addition, preparation and transportation of stored samples is inconvenient. In this study, a freeze-dried storage and preparation method was proposed to determine the presence of mycophenolic acid (MPA) in plasma. Fresh plasma samples were freeze-dried using a device, and then stored at ambient temperature. After the stored samples were soaked with methanol spiked with the internal standard, high-performance liquid chromatography was conducted to detect MPA. The proposed method was demonstrated to be precise and accurate over the linear range of 0.5-50 μg mL -1 , with both intra- and inter-day precision being <7% and biases <10%. The freeze-dried samples were stable at ambient temperature for at least 40 days. This method was also successfully applied to the pharmacokinetic study of MPA in healthy volunteers. Pharmacokinetic parameters, such as maximum plasma concentration, time point of maximum plasma concentration and elimination half-life, among others, were consistent with the results in the published study. This proposed technique was proved to be simple, reproducible and energy saving. This approach could also simplify the storage and analysis of samples in clinical and scientific drug research. Copyright © 2017 John Wiley & Sons, Ltd.
de Muinck, Eric J; Trosvik, Pål; Gilfillan, Gregor D; Hov, Johannes R; Sundaram, Arvind Y M
2017-07-06
Advances in sequencing technologies and bioinformatics have made the analysis of microbial communities almost routine. Nonetheless, the need remains to improve on the techniques used for gathering such data, including increasing throughput while lowering cost and benchmarking the techniques so that potential sources of bias can be better characterized. We present a triple-index amplicon sequencing strategy to sequence large numbers of samples at significantly lower c ost and in a shorter timeframe compared to existing methods. The design employs a two-stage PCR protocol, incorpo rating three barcodes to each sample, with the possibility to add a fourth-index. It also includes heterogeneity spacers to overcome low complexity issues faced when sequencing amplicons on Illumina platforms. The library preparation method was extensively benchmarked through analysis of a mock community in order to assess biases introduced by sample indexing, number of PCR cycles, and template concentration. We further evaluated the method through re-sequencing of a standardized environmental sample. Finally, we evaluated our protocol on a set of fecal samples from a small cohort of healthy adults, demonstrating good performance in a realistic experimental setting. Between-sample variation was mainly related to batch effects, such as DNA extraction, while sample indexing was also a significant source of bias. PCR cycle number strongly influenced chimera formation and affected relative abundance estimates of species with high GC content. Libraries were sequenced using the Illumina HiSeq and MiSeq platforms to demonstrate that this protocol is highly scalable to sequence thousands of samples at a very low cost. Here, we provide the most comprehensive study of performance and bias inherent to a 16S rRNA gene amplicon sequencing method to date. Triple-indexing greatly reduces the number of long custom DNA oligos required for library preparation, while the inclusion of variable length heterogeneity spacers minimizes the need for PhiX spike-in. This design results in a significant cost reduction of highly multiplexed amplicon sequencing. The biases we characterize highlight the need for highly standardized protocols. Reassuringly, we find that the biological signal is a far stronger structuring factor than the various sources of bias.
Evaluation of korzincalloy prepared by Hohman Plating
DOE Office of Scientific and Technical Information (OSTI.GOV)
Korinko, P. S.; Hollingshad, A. N.
2017-07-17
A commercial vendor, Hohman Plating performed contract engineering work to determine the feasibility of producing pin hole free KorZincAlloy bronze material used for zinc gettering. Samples were tested for Sn plating thickness, heat treatability, and chemistry prior to being subjected to a standardized zinc exposure. The samples absorbed zinc and were examined using visual and scanning electron microscopy. Hohman Plating successfully produced KZA that met the target composition, was pin hole free, and was an effective zinc getter.
Fort Ord Groundwater Remediation Studies, 2002 - 2005
2006-08-01
Groundwater was also directly sampled from a well OU1-36 with a bailer using an acid - cleaned bailer to determine whether comparable levels of trace...collected for the analysis of total chromium. The total chromium and Cr(VI) samples were collected in acid -clean low density polyethylene (LDPE) bottles...and 69Ga to be used as an internal standard. Acetic acid /ammonia buffer solution was prepared by slow addition of 15 mL of aqueous ammonia (20–22
Qi, Feifei; Jian, Ningge; Qian, Liangliang; Cao, Weixin; Xu, Qian; Li, Jian
2017-09-01
A simple and efficient three-step sample preparation method was developed and optimized for the simultaneous analysis of illegal anionic and cationic dyes (acid orange 7, metanil yellow, auramine-O, and chrysoidine) in food samples. A novel solid-phase extraction (SPE) procedure based on nanofibers mat (NFsM) was proposed after solvent extraction and freeze-salting out purification. The preferred SPE sorbent was selected from five functionalized NFsMs by orthogonal experimental design, and the optimization of SPE parameters was achieved through response surface methodology (RSM) based on the Box-Behnken design (BBD). Under the optimal conditions, the target analytes could be completely adsorbed by polypyrrole-functionalized polyacrylonitrile NFsM (PPy/PAN NFsM), and the eluent was directly analyzed by high-performance liquid chromatography-diode array detection (HPLC-DAD). The limits of detection (LODs) were between 0.002 and 0.01 mg kg -1 , and satisfactory linearity with correlation coefficients (R > 0.99) for each dye in all samples was achieved. Compared with the Chinese standard method and the published methods, the proposed method was simplified greatly with much lower requirement of sorbent (5.0 mg) and organic solvent (2.8 mL) and higher sample preparation speed (10 min/sample), while higher recovery (83.6-116.5%) and precision (RSDs < 7.1%) were obtained. With this developed method, we have successfully detected illegal ionic dyes in three common representative foods: yellow croaker, soybean products, and chili seasonings. Graphical abstract Schematic representation of the process of the three-step sample preparation.
A rapid method for estimation of Pu-isotopes in urine samples using high volume centrifuge.
Kumar, Ranjeet; Rao, D D; Dubla, Rupali; Yadav, J R
2017-07-01
The conventional radio-analytical technique used for estimation of Pu-isotopes in urine samples involves anion exchange/TEVA column separation followed by alpha spectrometry. This sequence of analysis consumes nearly 3-4 days for completion. Many a times excreta analysis results are required urgently, particularly under repeat and incidental/emergency situations. Therefore, there is need to reduce the analysis time for the estimation of Pu-isotopes in bioassay samples. This paper gives the details of standardization of a rapid method for estimation of Pu-isotopes in urine samples using multi-purpose centrifuge, TEVA resin followed by alpha spectrometry. The rapid method involves oxidation of urine samples, co-precipitation of plutonium along with calcium phosphate followed by sample preparation using high volume centrifuge and separation of Pu using TEVA resin. Pu-fraction was electrodeposited and activity estimated using 236 Pu tracer recovery by alpha spectrometry. Ten routine urine samples of radiation workers were analyzed and consistent radiochemical tracer recovery was obtained in the range 47-88% with a mean and standard deviation of 64.4% and 11.3% respectively. With this newly standardized technique, the whole analytical procedure is completed within 9h (one working day hour). Copyright © 2017 Elsevier Ltd. All rights reserved.
Vu, Dai Long; Ranglová, Karolína; Hájek, Jan; Hrouzek, Pavel
2018-05-01
Quantification of selenated amino-acids currently relies on methods employing inductively coupled plasma mass spectrometry (ICP-MS). Although very accurate, these methods do not allow the simultaneous determination of standard amino-acids, hampering the comparison of the content of selenated versus non-selenated species such as methionine (Met) and selenomethionine (SeMet). This paper reports two approaches for the simultaneous quantification of Met and SeMet. In the first approach, standard enzymatic hydrolysis employing Protease XIV was applied for the preparation of samples. The second approach utilized methanesulfonic acid (MA) for the hydrolysis of samples, either in a reflux system or in a microwave oven, followed by derivatization with diethyl ethoxymethylenemalonate. The prepared samples were then analyzed by multiple reaction monitoring high performance liquid chromatography tandem mass spectrometry (MRM-HPLC-MS/MS). Both approaches provided platforms for the accurate determination of selenium/sulfur substitution rate in Met. Moreover the second approach also provided accurate simultaneous quantification of Met and SeMet with a low limit of detection, low limit of quantification and wide linearity range, comparable to the commonly used gas chromatography mass spectrometry (GC-MS) method or ICP-MS. The novel method was validated using certified reference material in conjunction with the GC-MS reference method. Copyright © 2018. Published by Elsevier B.V.
Photolysis of RDX in Aqueous Solution, With and Without Ozone
1979-02-09
and compared with a standard prepared from the same TNT solution and an accurately weighed RDX sample in acetone ( 40 ppm). The GC analysis of the...aqueous carbon-14 RDX agreed with the weight ( 40 ppm). A stock solution of carbon-12 RDX in tap water was prepared by stirring an excess of RDX in 2 liters...as volatiles 8.4% " i10 7, 77 Y 40 ’ NSWC/WOL TR 78-175 Chemical Analysis of Acidified Reaction Mixture Nitrate ion: 4.91 x 10- M Ammonia: 2.5 x 10 -4
X-ray fluorescence analysis of K, Al and trace elements in chloroaluminate melts
NASA Astrophysics Data System (ADS)
Shibitko, A. O.; Abramov, A. V.; Denisov, E. I.; Lisienko, D. G.; Rebrin, O. I.; Bunkov, G. M.; Rychkov, V. N.
2017-09-01
Energy dispersive x-ray fluorescence spectrometry was applied to quantitative determination of K, Al, Cr, Fe and Ni in chloroaluminate melts. To implement the external standard calibration method, an unconventional way of samples preparation was suggested. A mixture of metal chlorides was melted in a quartz cell at 350-450 °C under a slightly excessive pressure of purified argon (99.999 %). The composition of the calibration samples (CSs) prepared was controlled by means of the inductively coupled plasma atomic emission spectrometry (ICP-AES). The optimal conditions for analytical lines excitation were determined, the analytes calibration curves were obtained. There was some influence of matrix effects in synthesized samples on the analytical signal of some elements. The CSs are to be stored in inert gas atmosphere. The precision, accuracy, and reproducibility factors of the quantitative chemical analysis were computed.
Optofluidic analysis system for amplification-free, direct detection of Ebola infection
NASA Astrophysics Data System (ADS)
Cai, H.; Parks, J. W.; Wall, T. A.; Stott, M. A.; Stambaugh, A.; Alfson, K.; Griffiths, A.; Mathies, R. A.; Carrion, R.; Patterson, J. L.; Hawkins, A. R.; Schmidt, H.
2015-09-01
The massive outbreak of highly lethal Ebola hemorrhagic fever in West Africa illustrates the urgent need for diagnostic instruments that can identify and quantify infections rapidly, accurately, and with low complexity. Here, we report on-chip sample preparation, amplification-free detection and quantification of Ebola virus on clinical samples using hybrid optofluidic integration. Sample preparation and target preconcentration are implemented on a PDMS-based microfluidic chip (automaton), followed by single nucleic acid fluorescence detection in liquid-core optical waveguides on a silicon chip in under ten minutes. We demonstrate excellent specificity, a limit of detection of 0.2 pfu/mL and a dynamic range of thirteen orders of magnitude, far outperforming other amplification-free methods. This chip-scale approach and reduced complexity compared to gold standard RT-PCR methods is ideal for portable instruments that can provide immediate diagnosis and continued monitoring of infectious diseases at the point-of-care.
Sonnante, Gabriella; Montemurro, Cinzia; Morgese, Anita; Sabetta, Wilma; Blanco, Antonio; Pasqualone, Antonella
2009-11-11
Italian industrial pasta and durum wheat typical breads must be prepared using exclusively durum wheat semolina. Previously, a microsatellite sequence specific of the wheat D-genome had been chosen for traceability of soft wheat in semolina and bread samples, using qualitative and quantitative Sybr green-based real-time experiments. In this work, we describe an improved method based on the same soft wheat genomic region by means of a quantitative real-time PCR using a dual-labeled probe. Standard curves based on dilutions of 100% soft wheat flour, pasta, or bread were constructed. Durum wheat semolina, pasta, and bread samples were prepared with increasing amounts of soft wheat to verify the accuracy of the method. Results show that reliable quantifications were obtained especially for the samples containing a lower amount of soft wheat DNA, fulfilling the need to verify labeling of pasta and typical durum wheat breads.
Onofrejová, Lucia; Farková, Marta; Preisler, Jan
2009-04-13
The application of an internal standard in quantitative analysis is desirable in order to correct for variations in sample preparation and instrumental response. In mass spectrometry of organic compounds, the internal standard is preferably labelled with a stable isotope, such as (18)O, (15)N or (13)C. In this study, a method for the quantification of fructo-oligosaccharides using matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI TOF MS) was proposed and tested on raftilose, a partially hydrolysed inulin with a degree of polymeration 2-7. A tetraoligosaccharide nystose, which is chemically identical to the raftilose tetramer, was used as an internal standard rather than an isotope-labelled analyte. Two mathematical approaches used for data processing, conventional calculations and artificial neural networks (ANN), were compared. The conventional data processing relies on the assumption that a constant oligomer dispersion profile will change after the addition of the internal standard and some simple numerical calculations. On the other hand, ANN was found to compensate for a non-linear MALDI response and variations in the oligomer dispersion profile with raftilose concentration. As a result, the application of ANN led to lower quantification errors and excellent day-to-day repeatability compared to the conventional data analysis. The developed method is feasible for MS quantification of raftilose in the range of 10-750 pg with errors below 7%. The content of raftilose was determined in dietary cream; application can be extended to other similar polymers. It should be stressed that no special optimisation of the MALDI process was carried out. A common MALDI matrix and sample preparation were used and only the basic parameters, such as sampling and laser energy, were optimised prior to quantification.
Pursuing the Depths of Knowledge
ERIC Educational Resources Information Center
Boyles, Nancy
2016-01-01
Today's state literacy standards and assessments demand deeper levels of knowledge from students. But many teachers ask, "What does depth of knowledge look like on these new, more rigorous assessments? How do we prepare students for this kind of thinking?" In this article, Nancy Boyles uses a sampling of questions from the PARCC and SBAC…
40 CFR 61.68 - Emission monitoring.
Code of Federal Regulations, 2010 CFR
2010-07-01
... basis and analyzes the samples with gas chromatography or, if the owner or operator assumes that all... calibration gas mixture prepared from the gases specified in Sections 7.2.1 and 7.2.2 of Method 106 and in accordance with Section 10.1 of Method 106, or (2) A calibration gas cylinder standard containing the...
40 CFR 61.68 - Emission monitoring.
Code of Federal Regulations, 2011 CFR
2011-07-01
... basis and analyzes the samples with gas chromatography or, if the owner or operator assumes that all... calibration gas mixture prepared from the gases specified in Sections 7.2.1 and 7.2.2 of Method 106 and in accordance with Section 10.1 of Method 106, or (2) A calibration gas cylinder standard containing the...
Structural tailoring of advanced turboprops (STAT): User's manual
NASA Technical Reports Server (NTRS)
Brown, K. W.
1991-01-01
This user's manual describes the Structural Tailoring of Advanced Turboprops program. It contains instructions to prepare the input for optimization, blade geometry and analysis, geometry generation, and finite element program control. In addition, a sample input file is provided as well as a section describing special applications (i.e., non-standard input).
21 CFR 320.31 - Applicability of requirements regarding an “Investigational New Drug Application.”
Code of Federal Regulations, 2013 CFR
2013-04-01
... article and reference standard used in the study and release the reserve samples to FDA upon request, in... electronic submission (e.g., method of transmission, media, file formats, preparation and organization of... Evaluation and Research at FDA. Relevant followup information to a bioavailability/bioequivalence safety...
21 CFR 320.31 - Applicability of requirements regarding an “Investigational New Drug Application.”
Code of Federal Regulations, 2011 CFR
2011-04-01
... article and reference standard used in the study and release the reserve samples to FDA upon request, in... electronic submission (e.g., method of transmission, media, file formats, preparation and organization of... Evaluation and Research at FDA. Relevant followup information to a bioavailability/bioequivalence safety...
21 CFR 320.31 - Applicability of requirements regarding an “Investigational New Drug Application.”
Code of Federal Regulations, 2012 CFR
2012-04-01
... article and reference standard used in the study and release the reserve samples to FDA upon request, in... electronic submission (e.g., method of transmission, media, file formats, preparation and organization of... Evaluation and Research at FDA. Relevant followup information to a bioavailability/bioequivalence safety...
21 CFR 320.31 - Applicability of requirements regarding an “Investigational New Drug Application.”
Code of Federal Regulations, 2014 CFR
2014-04-01
... article and reference standard used in the study and release the reserve samples to FDA upon request, in... electronic submission (e.g., method of transmission, media, file formats, preparation and organization of... Evaluation and Research at FDA. Relevant followup information to a bioavailability/bioequivalence safety...
A proteomics performance standard to support measurement quality in proteomics.
Beasley-Green, Ashley; Bunk, David; Rudnick, Paul; Kilpatrick, Lisa; Phinney, Karen
2012-04-01
The emergence of MS-based proteomic platforms as a prominent technology utilized in biochemical and biomedical research has increased the need for high-quality MS measurements. To address this need, National Institute of Standards and Technology (NIST) reference material (RM) 8323 yeast protein extract is introduced as a proteomics quality control material for benchmarking the preanalytical and analytical performance of proteomics-based experimental workflows. RM 8323 yeast protein extract is based upon the well-characterized eukaryote Saccharomyces cerevisiae and can be utilized in the design and optimization of proteomics-based methodologies from sample preparation to data analysis. To demonstrate its utility as a proteomics quality control material, we coupled LC-MS/MS measurements of RM 8323 with the NIST MS Quality Control (MSQC) performance metrics to quantitatively assess the LC-MS/MS instrumentation parameters that influence measurement accuracy, repeatability, and reproducibility. Due to the complexity of the yeast proteome, we also demonstrate how NIST RM 8323, along with the NIST MSQC performance metrics, can be used in the evaluation and optimization of proteomics-based sample preparation methods. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Brett, Sabine I; Lucien, Fabrice; Guo, Charles; Williams, Karla C; Kim, Yohan; Durfee, Paul N; Brinker, C J; Chin, Joseph I; Yang, Jun; Leong, Hon S
2017-05-01
The ability to isolate extracellular vesicles (EVs) such as exosomes or microparticles is an important method that is currently not standardized. While commercially available kits offer purification of EVs from biofluids, such purified EV samples will also contain non-EV entities such as soluble protein and nucleic acids that could confound subsequent experimentation. Ideally, only EVs would be isolated and no soluble protein would be present in the final EV preparation. We compared commercially available EV isolation kits with immunoaffinity purification techniques and evaluated our final EV preparations using atomic force microscopy (AFM) and nanoscale flow cytometry (NFC). AFM is the only modality capable of detecting distinguishing soluble protein from EVs which is important for downstream proteomics approaches. NFC is the only technique capable of quantitating the proportion of target EVs to non-target EVs in the final EV preparation. To determine enrichment of prostate derived EVs relative to non-target MPs, anti-PSMA (Prostate Specific Membrane Antigen) antibodies were used in NFC. Antibody-based immunoaffinity purification generated the highest quality of prostate derived EV preparations due to the lack of protein and RNA present in the samples. All kits produced poor purity EV preparations that failed to deplete the sample of plasma protein. While attractive due to their ease of use, EV purification kits do not provide substantial improvements in isolation of EVs from biofluids such as plasma. Immunoaffinity approaches are more efficient and economical and will also eliminate a significant portion of plasma proteins which is necessary for downstream approaches. © 2017 Wiley Periodicals, Inc.
Srivastava, Praveen; Moorthy, Ganesh S; Gross, Robert; Barrett, Jeffrey S
2013-01-01
A selective and a highly sensitive method for the determination of the non-nucleoside reverse transcriptase inhibitor (NNRTI), efavirenz, in human plasma has been developed and fully validated based on high performance liquid chromatography tandem mass spectrometry (LC-MS/MS). Sample preparation involved protein precipitation followed by one to one dilution with water. The analyte, efavirenz was separated by high performance liquid chromatography and detected with tandem mass spectrometry in negative ionization mode with multiple reaction monitoring. Efavirenz and ¹³C₆-efavirenz (Internal Standard), respectively, were detected via the following MRM transitions: m/z 314.20243.90 and m/z 320.20249.90. A gradient program was used to elute the analytes using 0.1% formic acid in water and 0.1% formic acid in acetonitrile as mobile phase solvents, at a flow-rate of 0.3 mL/min. The total run time was 5 min and the retention times for the internal standard (¹³C₆-efavirenz) and efavirenz was approximately 2.6 min. The calibration curves showed linearity (coefficient of regression, r>0.99) over the concentration range of 1.0-2,500 ng/mL. The intraday precision based on the standard deviation of replicates of lower limit of quantification (LLOQ) was 9.24% and for quality control (QC) samples ranged from 2.41% to 6.42% and with accuracy from 112% and 100-111% for LLOQ and QC samples. The inter day precision was 12.3% and 3.03-9.18% for LLOQ and quality controls samples, and the accuracy was 108% and 95.2-108% for LLOQ and QC samples. Stability studies showed that efavirenz was stable during the expected conditions for sample preparation and storage. The lower limit of quantification for efavirenz was 1 ng/mL. The analytical method showed excellent sensitivity, precision, and accuracy. This method is robust and is being successfully applied for therapeutic drug monitoring and pharmacokinetic studies in HIV-infected patients.
Hua, Li; Wu, Yi-Ping; An, Bing; Lai, Xiao-Wei
2008-11-01
The harm of heavy metals contained in electronic and electrical equipment (EEE) on environment is of high concern by human. Aiming to handle the great challenge of RoHS compliance, the determinations of trace or ultratrace chromium (Cr), cadmium (Cd), mercury (Hg) and lead (Pb) by inductively coupled plasma optical emission spectrometry (ICP-OES) was performed in the present paper, wherein, microwave extraction technology was used to prepare the sample solutions. In addition, the precision, recovery, repeatability and interference issues of this method were also discussed. The results exhibited that using the microwave extraction system to prepare samples is more quick, lossless, contamination-free in comparison with the conventional extraction methods such as dry ashing, wet-oven extraction etc. By analyzing the recoveries of these four heavy metals over different working time and wavelengths, the good recovery range between 85% and 115% showed that there was only tiny loss or contamination during the process of microwave extraction, sample introduction and ICP detection. Repeatability experiments proved that ICP plasma had a good stability during the working time and the matrix effect was small. Interference was a problem troublesome for atomic absorption spectrometry (AAS), however, the techniques of standard additions or inter-element correction (IEC) method can effectively eliminated the interferences of Ni, As, Fe etc. with the Cd determination. By employing the multi-wavelengths and two correction point methods, the issues of background curve sloping shift and spectra overlap were successfully overcome. Besides, for the determinations of trace heavy metal elements, the relative standard deviation (RSD) was less than 3% and the detection limits were less than 1 microg x L(-10 (3sigma, n = 5) for samples, standard solutions, and standard additions, which proved that ICP-OES has a good precision and high reliability. This provided a reliable technique support for electronic and electrical (EE) industries to comply with RoHS directive.
Zinc thermal spray coatings for reinforced concrete: An AWS process standard
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sulit, R.A.
Zinc and aluminum thermal spray coatings (TSC) have been used for lining concrete weir in Great Britain since the 1950`s to maintain the dimensions of the weir for flow control concomitant with reduced wear and erosion of the concrete surfaces. This paper reports the development and the content of the ANSI/AWS C2.20-XX standard for the application of An TSC on concrete using flame and arc spray processes. This standard is formatted as an industrial process instruction: job description; safety; feedstock materials; equipment; a step-by-step method for surface preparation, thermal spraying; quality control; repair and maintenance of surface preparation, thermal spraying;more » quality control; repair and maintenance of Zn TSC on concrete; and a Job Control Record. Job planning and training and certification requirements are presented for An TSC inspectors and thermal spray operators. Four annexes are included in the standard: (a) historical summary of Zn TSC on concrete (b) sample job control record; (c) thermal spray operator qualification; and (d) portable adhesion testing for An TSC on concrete. This standard is based on the current literature and industrial equipment, process, and practices.« less
Determination of total sulfur in lichens and plants by combustion-infrared analysis
Jackson, L.L.; Engleman, E.E.; Peard, J.L.
1985-01-01
Sulfur was determined in plants and lichens by combustion of the sample and infrared detection of evolved sulfur dioxide using an automated sulfur analyzer. Vanadium pentaoxide was used as a combustion accelerator. Pelletization of the sample prior to combustion was not found to be advantageous. Washing studies showed that leaching of sulfur was not a major factor in the sample preparation. The combustion-IR analysis usually gave higher sulfur content than the turbidimetric analysis as well as shorter analysis time. Relative standard deviations of less than 7% were obtained by the combustion-IR technique when sulfur levels in plant material ranged from 0.05 to 0.70%. Determination of sulfur in National Bureau of Standards botanical reference materials showed good agreement between the combustion-IR technique and other instrumental procedures. Seven NBS botanical reference materials were analyzed.
Duo, Jia; Dong, Huijin; DeSilva, Binodh; Zhang, Yan J
2013-07-01
Sample dilution and reagent pipetting are time-consuming steps in ligand-binding assays (LBAs). Traditional automation-assisted LBAs use assay-specific scripts that require labor-intensive script writing and user training. Five major script modules were developed on Tecan Freedom EVO liquid handling software to facilitate the automated sample preparation and LBA procedure: sample dilution, sample minimum required dilution, standard/QC minimum required dilution, standard/QC/sample addition, and reagent addition. The modular design of automation scripts allowed the users to assemble an automated assay with minimal script modification. The application of the template was demonstrated in three LBAs to support discovery biotherapeutic programs. The results demonstrated that the modular scripts provided the flexibility in adapting to various LBA formats and the significant time saving in script writing and scientist training. Data generated by the automated process were comparable to those by manual process while the bioanalytical productivity was significantly improved using the modular robotic scripts.
Metabolomic analysis using porcine skin: a pilot study of analytical techniques.
Wu, Julie; Fiehn, Oliver; Armstrong, April W
2014-06-15
Metabolic byproducts serve as indicators of the chemical processes and can provide valuable information on pathogenesis by measuring the amplified output. Standardized techniques for metabolome extraction of skin samples serve as a critical foundation to this field but have not been developed. We sought to determine the optimal cell lysage techniques for skin sample preparation and to compare GC-TOF-MS and UHPLC-QTOF-MS for metabolomic analysis. Using porcine skin samples, we pulverized the skin via various combinations of mechanical techniques for cell lysage. After extraction, the samples were subjected to GC-TOF-MS and/or UHPLC-QTOF-MS. Signal intensities from GC-TOF-MS analysis showed that ultrasonication (2.7x107) was most effective for cell lysage when compared to mortar-and-pestle (2.6x107), ball mill followed by ultrasonication (1.6x107), mortar-and-pestle followed by ultrasonication (1.4x107), and homogenization (trial 1: 8.4x106; trial 2: 1.6x107). Due to the similar signal intensities, ultrasonication and mortar-and-pestle were applied to additional samples and subjected to GC-TOF-MS and UHPLC-QTOF-MS. Ultrasonication yielded greater signal intensities than mortar-and-pestle for 92% of detected metabolites following GC-TOF-MS and for 68% of detected metabolites following UHPLC-QTOF-MS. Overall, ultrasonication is the preferred method for efficient cell lysage of skin tissue for both metabolomic platforms. With standardized sample preparation, metabolomic analysis of skin can serve as a powerful tool in elucidating underlying biological processes in dermatological conditions.
Buzzi, Marina; Guarino, Anna; Gatto, Claudio; Manara, Sabrina; Dainese, Luca; Polvani, Gianluca; Tóthová, Jana D'Amato
2014-01-01
We investigated the presence of antibiotics in cryopreserved cardiovascular tissues and cryopreservation media, after tissue decontamination with antibiotic cocktails, and the impact of antibiotic residues on standard tissue bank microbiological analyses. Sixteen cardiovascular tissues were decontaminated with bank-prepared cocktails and cryopreserved by two different tissue banks according to their standard operating procedures. Before and after decontamination, samples underwent microbiological analysis by standard tissue bank methods. Cryopreserved samples were tested again with and without the removal of antibiotic residues using a RESEP tube, after thawing. Presence of antibiotics in tissue homogenates and processing liquids was determined by a modified agar diffusion test. All cryopreserved tissue homogenates and cryopreservation media induced important inhibition zones on both Staphylococcus aureus- and Pseudomonas aeruginosa-seeded plates, immediately after thawing and at the end of the sterility test. The RESEP tube treatment markedly reduced or totally eliminated the antimicrobial activity of tested tissues and media. Based on standard tissue bank analysis, 50% of tissues were found positive for bacteria and/or fungi, before decontamination and 2 out of 16 tested samples (13%) still contained microorganisms after decontamination. After thawing, none of the 16 cryopreserved samples resulted positive with direct inoculum method. When the same samples were tested after removal of antibiotic residues, 8 out of 16 (50%) were contaminated. Antibiotic residues present in tissue allografts and processing liquids after decontamination may mask microbial contamination during microbiological analysis performed with standard tissue bank methods, thus resulting in false negatives.
Gatto, Claudio; Manara, Sabrina; Dainese, Luca; Polvani, Gianluca; Tóthová, Jana D'Amato
2014-01-01
We investigated the presence of antibiotics in cryopreserved cardiovascular tissues and cryopreservation media, after tissue decontamination with antibiotic cocktails, and the impact of antibiotic residues on standard tissue bank microbiological analyses. Sixteen cardiovascular tissues were decontaminated with bank-prepared cocktails and cryopreserved by two different tissue banks according to their standard operating procedures. Before and after decontamination, samples underwent microbiological analysis by standard tissue bank methods. Cryopreserved samples were tested again with and without the removal of antibiotic residues using a RESEP tube, after thawing. Presence of antibiotics in tissue homogenates and processing liquids was determined by a modified agar diffusion test. All cryopreserved tissue homogenates and cryopreservation media induced important inhibition zones on both Staphylococcus aureus- and Pseudomonas aeruginosa-seeded plates, immediately after thawing and at the end of the sterility test. The RESEP tube treatment markedly reduced or totally eliminated the antimicrobial activity of tested tissues and media. Based on standard tissue bank analysis, 50% of tissues were found positive for bacteria and/or fungi, before decontamination and 2 out of 16 tested samples (13%) still contained microorganisms after decontamination. After thawing, none of the 16 cryopreserved samples resulted positive with direct inoculum method. When the same samples were tested after removal of antibiotic residues, 8 out of 16 (50%) were contaminated. Antibiotic residues present in tissue allografts and processing liquids after decontamination may mask microbial contamination during microbiological analysis performed with standard tissue bank methods, thus resulting in false negatives. PMID:25397402
NASA Astrophysics Data System (ADS)
Verma, Vivek; Pandey, Vibhav; Singh, Sukhveer; Aloysius, R. P.; Annapoorni, S.; Kotanala, R. K.
2009-08-01
Lithium ferrite has been considered as one of the highly strategic magnetic material. Nano-crystalline Li 0.5Fe 2.5O 4 was prepared by four different techniques and characterized by X-ray diffraction, vibrating sample magnetometer (VSM), transmission electron microscope (TEM) and Fourier transform infrareds (FTIR). The effect of annealing temperature (700, 900 and 1050 °C) on microstructure has been correlated to the magnetic properties. From X-ray diffraction patterns, it is confirmed that the pure phase of lithium ferrite began to form at 900 °C annealing. The particle size of as-prepared lithium ferrite was observed around 40, 31, 22 and 93 nm prepared by flash combustion, sol-gel, citrate precursor and standard ceramic technique, respectively. Lithium ferrite prepared by citrate precursor method shows a maximum saturation magnetization 67.6 emu/g at 5 KOe.
Murphy, K E; Beary, E S; Rearick, M S; Vocke, R D
2000-10-01
Lead (Pb) and cadmium (Cd) have been determined in six new environmental standard reference materials (SRMs) using isotope dilution inductively coupled plasma mass spectrometry (ID ICP-MS). The SRMs are the following: SRM 1944, New York-New Jersey Waterway Sediment, SRMs 2583 and 2584, Trace Elements in Indoor Dust, Nominal 90 mg/kg and 10,000 mg/kg Lead, respectively, SRMs 2586 and 2587, Trace Elements in Soil Containing Lead from Paint, Nominal 500 mg/kg and 3,000 mg/kg Lead, respectively, and SRM 2782, Industrial Sludge. The capabilities of ID ICP-MS for the certification of Pb and Cd in these materials are assessed. Sample preparation and ratio measurement uncertainties have been evaluated. Reproducibility and accuracy of the established procedures are demonstrated by determination of gravimetrically prepared primary standard solutions and by comparison with isotope dilution thermal ionization mass spectrometry (ID TIMS). Material heterogeneity was readily demonstrated to be the dominant source of uncertainty in the certified values.
Effect of nano BiPb-2212 phase addition on BiPb-2223 phase properties
NASA Astrophysics Data System (ADS)
Mohammed, N. H.; Abou-Aly, A. I.; Barakat, M. Me.; Hassan, M. S.
2018-06-01
BiPb-2212 phase in nanoscale was added to BiPb-2223 phase with a general stoichiometry of (Bi1.7Pb0.4Sr2.1Ca1.1Cu2.1O8+δ)x/Bi1.8Pb0.4Sr2.0Ca2.0Cu3.2O10+δ, 0.0 ≤ x ≤ 2.5 wt.%. All samples were prepared by the standard solid-state reaction method. The prepared nano BiPb-2212 phase was characterized by X-ray powder diffraction (XRD) and transmission electron microscope (TEM). The prepared samples were characterized by XRD and the scanning electron microscope (SEM). XRD analysis indicated that the sample with x = 1.5 wt.% has the highest relative volume fraction for BiPb-2223 phase. Samples were examined by electrical resistivity and I-V measurements. There is no significant change in the superconducting transition temperature Tc for all samples. The highest critical current density Jc was recorded for the sample with x = 1.5 wt.%. The normalized excess conductivity (Δσ/σroom) was calculated according to Aslamazov-Larkin (AL) model. Four different fluctuating regions were recorded as the temperature decreased. The coherence length along the c-axis at 0 K ξc(0), interlayer coupling strength s, Fermi velocity vF of the carriers and Fermi energy EF were calculated for both samples with x = 0.0 wt.% and 1.5 wt.%.
Harju, Kirsi; Rapinoja, Marja-Leena; Avondet, Marc-André; Arnold, Werner; Schär, Martin; Burrell, Stephen; Luginbühl, Werner; Vanninen, Paula
2015-01-01
Saxitoxin (STX) and some selected paralytic shellfish poisoning (PSP) analogues in mussel samples were identified and quantified with liquid chromatography-tandem mass spectrometry (LC-MS/MS). Sample extraction and purification methods of mussel sample were optimized for LC-MS/MS analysis. The developed method was applied to the analysis of the homogenized mussel samples in the proficiency test (PT) within the EQuATox project (Establishment of Quality Assurance for the Detection of Biological Toxins of Potential Bioterrorism Risk). Ten laboratories from eight countries participated in the STX PT. Identification of PSP toxins in naturally contaminated mussel samples was performed by comparison of product ion spectra and retention times with those of reference standards. The quantitative results were obtained with LC-MS/MS by spiking reference standards in toxic mussel extracts. The results were within the z-score of ±1 when compared to the results measured with the official AOAC (Association of Official Analytical Chemists) method 2005.06, pre-column oxidation high-performance liquid chromatography with fluorescence detection (HPLC-FLD). PMID:26610567
Sisljagić, Vladimir; Jovanović, Savo; Mrcela, Tomislav; Radić, Radivoje; Belovari, Tatjana
2009-12-01
In surgery of fractured long bones, a patient suffering from osteoporosis represents constant challenge to a surgeon and applied material and instruments that need to destroy as little as possible of an already damaged bone. One potential way of increasing the contact surface between the implants and osteoporotic bone is injection of bone cement (methyl-metacrilat, Palakos) into a prepared screw bed. This method of osteosynthesis was therefore subjected to experimental research to prove that application of modified osteosynthesis using bone cement in treatment of fractures in osteoporotic patients has advantage over the standard method of osteosynthesis because this modified method enables significantly greater firmness and stability of the osteosynthesis, which is the essential precondition of a successful fracture healing. The research was carried out on six macerated cadaveric preparations of a shin bone from the osteological collection from Institute for Anatomy, School of Medicine, University "J. J. Strossmayer". All samples of long bones were artificially broken in the middle part of the diaphysis and then standard osteosynthesis and modified osteosynthesis with screws filled with bone cement were performed on the samples. Results show that under identical static action of the moment of torsion in the modified osteosynthesis torsion angle deviation is lower than in the standard osteosynthesis. In modified osteosynthesis with bone cement the first results for angle of torsion deviation greater than 0.2 degrees were noticed after 120 minutes, while in the standard method of osteosynthesis they were noticed already in the first minute.
This SOP describes the method used for preparing surrogate recovery standard and internal standard solutions for the analysis of polar target analytes. It also describes the method for preparing calibration standard solutions for polar analytes used for gas chromatography/mass sp...
Gmyr, Valery; Bonner, Caroline; Lukowiak, Bruno; Pawlowski, Valerie; Dellaleau, Nathalie; Belaich, Sandrine; Aluka, Isanga; Moermann, Ericka; Thevenet, Julien; Ezzouaoui, Rimed; Queniat, Gurvan; Pattou, Francois; Kerr-Conte, Julie
2015-01-01
Reliable assessment of islet viability, mass, and purity must be met prior to transplanting an islet preparation into patients with type 1 diabetes. The standard method for quantifying human islet preparations is by direct microscopic analysis of dithizone-stained islet samples, but this technique may be susceptible to inter-/intraobserver variability, which may induce false positive/negative islet counts. Here we describe a simple, reliable, automated digital image analysis (ADIA) technique for accurately quantifying islets into total islet number, islet equivalent number (IEQ), and islet purity before islet transplantation. Islets were isolated and purified from n = 42 human pancreata according to the automated method of Ricordi et al. For each preparation, three islet samples were stained with dithizone and expressed as IEQ number. Islets were analyzed manually by microscopy or automatically quantified using Nikon's inverted Eclipse Ti microscope with built-in NIS-Elements Advanced Research (AR) software. The AIDA method significantly enhanced the number of islet preparations eligible for engraftment compared to the standard manual method (p < 0.001). Comparisons of individual methods showed good correlations between mean values of IEQ number (r(2) = 0.91) and total islet number (r(2) = 0.88) and thus increased to r(2) = 0.93 when islet surface area was estimated comparatively with IEQ number. The ADIA method showed very high intraobserver reproducibility compared to the standard manual method (p < 0.001). However, islet purity was routinely estimated as significantly higher with the manual method versus the ADIA method (p < 0.001). The ADIA method also detected small islets between 10 and 50 µm in size. Automated digital image analysis utilizing the Nikon Instruments software is an unbiased, simple, and reliable teaching tool to comprehensively assess the individual size of each islet cell preparation prior to transplantation. Implementation of this technology to improve engraftment may help to advance the therapeutic efficacy and accessibility of islet transplantation across centers.
NASA Astrophysics Data System (ADS)
Mohamad, Mahirah; Ishak, Shareena; Jaafar, Rohana; Sani, Norrakiah Abdullah
2018-04-01
ATP Bioluminescence application and standard microbiological analyses were used to evaluate the cleanliness of milk contact surfaces and non-milk contact surfaces in milk preparation room of neonatal intensive care unit (NICU) of Universiti Kebangsaan Malaysia Medical Centre (UKMMC). A total of 44 samples including the breast pump, milk bottle, milk bottle screw top and screw ring, teats, measuring cups, waterless warmer, refrigerator, dishwasher and pasteurizer inner wall were tested on May 2017. 3M Clean and Trace Hygiene Monitoring (UXL100 ATP Test swabs) and the bioluminescence reader Clean-Trace NG Luminometer (3M) were used to measure the Relative Light Unit (RLU) and microbiological analysis using 3M Quick Swab and 3MTM PetrifilmTM for enumeration of aerobic count, Staphylococcus aureus, Enterobacteriaceae, coliform and detection of Escherichia coli (CFU /100cm2 or utensil/item). The RLU values were from 11 to 194 and passed the ATP benchmark for intensive care unit (ICU), < 250 RLU as recommended. Aerobic colony count was only found in waterless warmer (0.05±0.01 mean log CFU/warmer). None of S. aureus, Enterobacteriaceae, E. coli and coliform was detected in all samples. A weak correlation was found between bioluminescence measurements RLU and the microbiological analysis (CFU). However, the use of ATP bioluminescence in monitoring milk preparation room cleanliness can be a useful method for assessing rapidly the surface hygiene as well as to verify the Sanitation Standard Operating Procedure (SSOP) prior to implementation of Hazard Analysis and Critical Control Points (HACCP) in milk preparation room.
Robust Sub-nanomolar Library Preparation for High Throughput Next Generation Sequencing.
Wu, Wells W; Phue, Je-Nie; Lee, Chun-Ting; Lin, Changyi; Xu, Lai; Wang, Rong; Zhang, Yaqin; Shen, Rong-Fong
2018-05-04
Current library preparation protocols for Illumina HiSeq and MiSeq DNA sequencers require ≥2 nM initial library for subsequent loading of denatured cDNA onto flow cells. Such amounts are not always attainable from samples having a relatively low DNA or RNA input; or those for which a limited number of PCR amplification cycles is preferred (less PCR bias and/or more even coverage). A well-tested sub-nanomolar library preparation protocol for Illumina sequencers has however not been reported. The aim of this study is to provide a much needed working protocol for sub-nanomolar libraries to achieve outcomes as informative as those obtained with the higher library input (≥ 2 nM) recommended by Illumina's protocols. Extensive studies were conducted to validate a robust sub-nanomolar (initial library of 100 pM) protocol using PhiX DNA (as a control), genomic DNA (Bordetella bronchiseptica and microbial mock community B for 16S rRNA gene sequencing), messenger RNA, microRNA, and other small noncoding RNA samples. The utility of our protocol was further explored for PhiX library concentrations as low as 25 pM, which generated only slightly fewer than 50% of the reads achieved under the standard Illumina protocol starting with > 2 nM. A sub-nanomolar library preparation protocol (100 pM) could generate next generation sequencing (NGS) results as robust as the standard Illumina protocol. Following the sub-nanomolar protocol, libraries with initial concentrations as low as 25 pM could also be sequenced to yield satisfactory and reproducible sequencing results.
Greer, Colleen D; Hodson, Peter V; Li, Zhengkai; King, Thomas; Lee, Kenneth
2012-06-01
Tests of crude oil toxicity to fish are often chronic, exposing embryos from fertilization to hatch to oil solutions prepared using standard mixing procedures. However, during oil spills, fish are not often exposed for long periods and the dynamic nature of the ocean is not easily replicated in the lab. Our objective was to determine if brief exposures of Atlantic herring (Clupea harengus) embryos to dispersed oil prepared by standard mixing procedures was as toxic as oil dispersed in a more realistic model system. Embryos were first exposed to chemically dispersed Alaska North Slope crude and Arabian light crude oil for 2.4 h to 14 d from fertilization to determine if exposure time affected toxicity. Toxicity increased with exposure time, but 2.4-h exposures at realistic concentrations of oil induced blue-sac disease and reduced the percentage of normal embryos at hatch; there was little difference in toxicity between the two oils. Secondly, oil was chemically dispersed in a wave tank to determine if the resultant oil solutions were as toxic to herring embryos as laboratory-derived dispersed oil using a single exposure period of 24 h. Samples taken 15 min postdispersion were more toxic than laboratory-prepared solutions, but samples taken at 5, 30, and 60 min postdispersion were less toxic. Overall, the laboratory- and wave tank-derived solutions of dispersed oil provided similar estimates of toxicity despite differences in the methods for preparing test solutions, suggesting that laboratory and wave tank data are a reliable basis for ecological risk assessments of spilled oil. Copyright © 2012 SETAC.
Cytology Preparations of Formalin Fixative Aid Detection of Giardia in Duodenal Biopsy Samples.
Panarelli, Nicole C; Gobara, Nariman; Hoda, Rana S; Chaump, Michael; Jessurun, Jose; Yantiss, Rhonda K
2017-04-01
Giardiasis is the most common intestinal parasitic infection in the United States. The organism elicits no, or minimal, inflammatory changes in duodenal biopsy samples, so it can be easily overlooked. We performed this study to determine whether Giardia could be isolated from the formalin fixative of biopsy samples, and to evaluate the value of fluid analysis in the assessment for potential infection. We prospectively evaluated duodenal biopsy samples from 92 patients with a clinical suspicion of giardiasis or symptoms compatible with that diagnosis (ie, diarrhea, bloating, or abdominal pain) Biopsy samples were routinely processed and stained with hematoxylin and eosin. Histologic diagnoses included giardiasis (5 cases, 4%), normal findings (64 cases, 70%), peptic injury/active duodenitis (12 cases, 13%), and intraepithelial lymphocytosis with villous blunting (10 cases, 12%). Fifteen cases (13%) showed detached degenerated epithelial cells or mucus droplets in the intervillous space that resembled Giardia. Cytology slides were prepared from formalin in the biopsy container using the standard Cytospin protocol and reviewed by a cytopathologist blinded to the biopsy findings. Cytologic evaluation revealed Giardia spp. in all 5 biopsy-proven cases, and identified an additional case that was not detected by biopsy analysis. Organisms were significantly more numerous (mean: 400 trophozoites; range, 120 to 810) and showed better morphologic features in cytology preparations compared with tissue sections (mean: 129 trophozoites; range, 37 to 253 organisms; P=0.05). Our findings suggest that cytology preparations from formalin fixative can resolve diagnostically challenging cases and even enhance Giardia detection in some cases.
Delgado-Povedano, M M; Calderón-Santiago, M; Priego-Capote, F; Luque de Castro, M D
2016-01-01
The determination of physiological levels of amino acids is important to aid in the diagnosis and treatment of several diseases and nutritional status of individuals. Amino acids are frequently determined in biofluids such as blood (serum or plasma) and urine; however, there are less common biofluids with different concentration profiles of amino acids that could be of interest. One of these biofluids is sweat that can be obtained in a non-invasive manner and is characterized by low complex composition. The analysis of amino acids in human sweat requires the development of sample preparation strategies according to the sample matrix and small collected volume. The influence of sample preparation on the quantitative analysis of amino acids in sweat by LC-MS/MS has been assessed through a comparison between two strategies: dilution of sweat and centrifugal microsolid-phase extraction (c-μSPE). In both cases, several dilution factors were assayed for in-depth knowledge of the matrix effects, and the use of c-μSPE provided the best results in terms of accuracy. The behavior of the target analytes was a function of the dilution factor, thus providing a pattern for sample preparation that depended on the amino acid to be determined. The concentration of amino acids in sweat ranges between 6.20 ng mL(-1) (for homocysteine) and 259.77 µg mL(-1) (for serine) with precision, expressed as relative standard deviation, within 1.1-21.4%. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
López-García, I.; Viñas, P.; Romero-Romero, R.; Hernández-Córdoba, M.
2007-01-01
A procedure for the electrothermal atomic absorption spectrometric determination of phosphorus in honey, milk and infant formulas using slurried samples is described. Suspensions prepared in a medium containing 50% v/v concentrated hydrogen peroxide, 1% v/v concentrated nitric acid, 10% m/v glucose, 5% m/v sucrose and 100 mg l - 1 of potassium were introduced directly into the furnace. For the honey samples, multiple injection of the sample was necessary. The modifier selected was a mixture of 20 μg palladium and 5 μg magnesium nitrate, which was injected after the sample and before proceeding with the drying and calcination steps. Calibration was performed using aqueous standards prepared in the same suspension medium and the graph was linear between 5 and 80 mg l - 1 of phosphorus. The reliability of the procedure was checked by comparing the results obtained by the new developed method with those found when using a reference spectrophotometric method after a mineralization step, and by analyzing several certified reference materials.
Labat, L; Dehon, B; Lhermitte, M
2003-05-01
An inductively coupled plasma mass spectrometer (ICP-MS) with a rapid sample-preparative procedure was used for the determination of selenium in blood serum. Blood serum was prepared by dilution in an acidic solution consisting of nitric acid (1%), X-triton (0.1%) and 1-butanol (0.8%). A calibration curve was established for 1-40 microg mL(-1) (r(2)>0.99). The limit of detection was 0.5 microg mL(-1). Repeatability and intermediate precision were satisfactory with relative standard deviations (RSD) of 2.0% and 3.2%, respectively. This method was easily applied to reference materials with satisfactory accuracy. Good correlation (r(2)=0.96) was observed between ICP-MS and atomic absorption spectrometry (AAS) for the determination of (82)Se in blood serum from 23 patients. These results suggest that the sample preparative procedure coupled with ICP-MS can be used for the routine determination of (82)Se in human blood serum.
International Standards for Genomes, Transcriptomes, and Metagenomes
Mason, Christopher E.; Afshinnekoo, Ebrahim; Tighe, Scott; Wu, Shixiu; Levy, Shawn
2017-01-01
Challenges and biases in preparing, characterizing, and sequencing DNA and RNA can have significant impacts on research in genomics across all kingdoms of life, including experiments in single-cells, RNA profiling, and metagenomics (across multiple genomes). Technical artifacts and contamination can arise at each point of sample manipulation, extraction, sequencing, and analysis. Thus, the measurement and benchmarking of these potential sources of error are of paramount importance as next-generation sequencing (NGS) projects become more global and ubiquitous. Fortunately, a variety of methods, standards, and technologies have recently emerged that improve measurements in genomics and sequencing, from the initial input material to the computational pipelines that process and annotate the data. Here we review current standards and their applications in genomics, including whole genomes, transcriptomes, mixed genomic samples (metagenomes), and the modified bases within each (epigenomes and epitranscriptomes). These standards, tools, and metrics are critical for quantifying the accuracy of NGS methods, which will be essential for robust approaches in clinical genomics and precision medicine. PMID:28337071
Sample handling for mass spectrometric proteomic investigations of human sera.
West-Nielsen, Mikkel; Høgdall, Estrid V; Marchiori, Elena; Høgdall, Claus K; Schou, Christian; Heegaard, Niels H H
2005-08-15
Proteomic investigations of sera are potentially of value for diagnosis, prognosis, choice of therapy, and disease activity assessment by virtue of discovering new biomarkers and biomarker patterns. Much debate focuses on the biological relevance and the need for identification of such biomarkers while less effort has been invested in devising standard procedures for sample preparation and storage in relation to model building based on complex sets of mass spectrometric (MS) data. Thus, development of standardized methods for collection and storage of patient samples together with standards for transportation and handling of samples are needed. This requires knowledge about how sample processing affects MS-based proteome analyses and thereby how nonbiological biased classification errors are avoided. In this study, we characterize the effects of sample handling, including clotting conditions, storage temperature, storage time, and freeze/thaw cycles, on MS-based proteomics of human serum by using principal components analysis, support vector machine learning, and clustering methods based on genetic algorithms as class modeling and prediction methods. Using spiking to artificially create differentiable sample groups, this integrated approach yields data that--even when working with sample groups that differ more than may be expected in biological studies--clearly demonstrate the need for comparable sampling conditions for samples used for modeling and for the samples that are going into the test set group. Also, the study emphasizes the difference between class prediction and class comparison studies as well as the advantages and disadvantages of different modeling methods.
Hough, Rachael; Archer, Debra; Probert, Christopher
2018-01-01
Disturbance to the hindgut microbiota can be detrimental to equine health. Metabolomics provides a robust approach to studying the functional aspect of hindgut microorganisms. Sample preparation is an important step towards achieving optimal results in the later stages of analysis. The preparation of samples is unique depending on the technique employed and the sample matrix to be analysed. Gas chromatography mass spectrometry (GCMS) is one of the most widely used platforms for the study of metabolomics and until now an optimised method has not been developed for equine faeces. To compare a sample preparation method for extracting volatile organic compounds (VOCs) from equine faeces. Volatile organic compounds were determined by headspace solid phase microextraction gas chromatography mass spectrometry (HS-SPME-GCMS). Factors investigated were the mass of equine faeces, type of SPME fibre coating, vial volume and storage conditions. The resultant method was unique to those developed for other species. Aliquots of 1000 or 2000 mg in 10 ml or 20 ml SPME headspace were optimal. From those tested, the extraction of VOCs should ideally be performed using a divinylbenzene-carboxen-polydimethysiloxane (DVB-CAR-PDMS) SPME fibre. Storage of faeces for up to 12 months at - 80 °C shared a greater percentage of VOCs with a fresh sample than the equivalent stored at - 20 °C. An optimised method for extracting VOCs from equine faeces using HS-SPME-GCMS has been developed and will act as a standard to enable comparisons between studies. This work has also highlighted storage conditions as an important factor to consider in experimental design for faecal metabolomics studies.
ERIC Educational Resources Information Center
Bopegedera, A. M. R. P.
2016-01-01
General chemistry and introductory chemistry students were presented with a laboratory exploration for the determination of the mass percent of copper in rock and mineral samples. They worked independently in the laboratory, which involved multiple lab (pipetting, preparing standard solutions by quantitative dilution, recording visible spectra…
The purpose of this SOP is to describe procedures for extracting and preparing dust or soil samples for gas chromatography/mass spectrometry (GC/MS) analysis of pesticides. This procedure was followed to ensure consistent data retrieval during the Arizona NHEXAS project and the "...
The purpose of this SOP is to describe the general procedures to be followed for cleaning glassware used in preparing and analyzing soil, house dust, air filter, surface wipe, or dermal wash samples for inorganic metals. This procedure was followed to ensure consistent data retr...
Direct Compositional Characterization of (U,Th)O2 Powders, Microspheres, and Pellets Using TXRF.
Dhara, Sangita; Prabhat, Parimal; Misra, N L
2015-10-20
A total reflection X-ray fluorescence (TXRF) analysis method for direct compositional characterization of sintered and green (U,Th)O2 samples in different forms (e.g., pellets, powders, and microspheres) without sample dissolution has been developed for the first time. The methodology involves transfer of only a few nanograms of the sample on the TXRF sample support by gently rubbing the samples on supports or taking their tiny uniform slurry in collodion on the sample support, drying them to make thin film, and measuring the TXRF spectra of the specimens thus prepared. This approach minimizes the matrix effects. Uranium determinations from the TXRF spectra of such specimens were made with respect to thorium, considering it as an internal standard. Samples having uranium atom percent (at%) from 0 to 100 in (U,Th)O2 were analyzed for uranium in comparison to thorium. The results showed an average precision of 2.6% (RSD, 2σ, n = 8). The TXRF-determined results deviated from expected values within 5%. The TXRF results were compared with those of biamperometry with good agreement. The lattice parameters of the solid solutions were calculated using their XRD patterns. A good correlation between lattice parameters and TXRF-determined U at% and between TXRF-determined U at% and expected U at%, calculated on the basis of preparation of (U,Th)O2 solid solutions, was obtained. The developed method is capable of analyzing (U,Th)O2 samples directly with almost negligible sample preparation and is well suited for radioactive samples. The present study suggests that this method can be extended for the determination of U,Th and Pu in other nuclear fuel materials (e.g., nitrides, carbides, etc.) in the form of pellets, powders, and microspheres after suitable modifications in sample handling procedure.
Characterization of fission gas bubbles in irradiated U-10Mo fuel
DOE Office of Scientific and Technical Information (OSTI.GOV)
Casella, Andrew M.; Burkes, Douglas E.; MacFarlan, Paul J.
2017-09-01
Irradiated U-10Mo fuel samples were prepared with traditional mechanical potting and polishing methods with in a hot cell. They were then removed and imaged with an SEM located outside of a hot cell. The images were then processed with basic imaging techniques from 3 separate software packages. The results were compared and a baseline method for characterization of fission gas bubbles in the samples is proposed. It is hoped that through adoption of or comparison to this baseline method that sample characterization can be somewhat standardized across the field of post irradiated examination of metal fuels.
Recommendations and calculations concerning physical characteristics of the EEVT apparatus
NASA Technical Reports Server (NTRS)
1985-01-01
Several issues arose during the course of preparing for the flight of EEVT on STS-3. Documents concerning the issues are presented in the following order: (1) the possibility of mixing latex spheres with kidney cells as standard electrokinetic markers; (2) tube breakage and the potential for the development of leaks and bubbles; (3) effects of the shape of the sample gate on the electric field and the outward migration of cells; (4) suggestions for reducing electroosmosis by decreasing the diameter of the sample; and (5) predictions of the effects of modified sample dimensions on electroosmotic band spreading.
A brief overview on radon measurements in drinking water.
Jobbágy, Viktor; Altzitzoglou, Timotheos; Malo, Petya; Tanner, Vesa; Hult, Mikael
2017-07-01
The aim of this paper is to present information about currently used standard and routine methods for radon analysis in drinking waters. An overview is given about the current situation and the performance of different measurement methods based on literature data. The following parameters are compared and discussed: initial sample volume and sample preparation, detection systems, minimum detectable activity, counting efficiency, interferences, measurement uncertainty, sample capacity and overall turnaround time. Moreover, the parametric levels for radon in drinking water from the different legislations and directives/guidelines on radon are presented. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Marinova, Mariela; Artusi, Carlo; Brugnolo, Laura; Antonelli, Giorgia; Zaninotto, Martina; Plebani, Mario
2013-11-01
Although, due to its high specificity and sensitivity, LC-MS/MS is an efficient technique for the routine determination of immunosuppressants in whole blood, it involves time-consuming manual sample preparation. The aim of the present study was therefore to develop an automated sample-preparation protocol for the quantification of sirolimus, everolimus and tacrolimus by LC-MS/MS using a liquid handling platform. Six-level commercially available blood calibrators were used for assay development, while four quality control materials and three blood samples from patients under immunosuppressant treatment were employed for the evaluation of imprecision. Barcode reading, sample re-suspension, transfer of whole blood samples into 96-well plates, addition of internal standard solution, mixing, and protein precipitation were performed with a liquid handling platform. After plate filtration, the deproteinised supernatants were submitted for SPE on-line. The only manual steps in the entire process were de-capping of the tubes, and transfer of the well plates to the HPLC autosampler. Calibration curves were linear throughout the selected ranges. The imprecision and accuracy data for all analytes were highly satisfactory. The agreement between the results obtained with manual and those obtained with automated sample preparation was optimal (n=390, r=0.96). In daily routine (100 patient samples) the typical overall total turnaround time was less than 6h. Our findings indicate that the proposed analytical system is suitable for routine analysis, since it is straightforward and precise. Furthermore, it incurs less manual workload and less risk of error in the quantification of whole blood immunosuppressant concentrations than conventional methods. © 2013.
Calibration of equipment for analysis of drinking water fluoride: a comparison study.
Quock, Ryan L; Chan, Jarvis T
2012-03-01
Current American Dental Association evidence-based recommendations for prescription of dietary fluoride supplements are based in part on the fluoride concentration of a pediatric patient's drinking water. With these recommendations in mind, this study compared the relative accuracy of fluoride concentration analysis when a common apparatus is calibrated with different combinations of standard values. Fluoride solutions in increments of 0.1 ppm, from a range of 0.1 to 1.0 ppm fluoride, as well as 2.0 and 4.0 ppm, were gravimetrically prepared and fluoride concentration measured in pentad, using a fluoride ion-specific electrode and millivolt meter. Fluoride concentrations of these solutions were recorded after calibration with the following 3 different combinations of standard fluoride solutions: 0.1 ppm and 0.5 ppm, 0.1 ppm and 1.0 ppm, 0.5 ppm and 1.0 ppm. Statistical analysis showed significant differences in the fluoride content of water samples obtained with different two-standard fluoride solutions. Among the two-standard fluoride solutions tested, using 0.5 ppm and 1.0 ppm as two-standard fluoride solutions provided the most accurate fluoride measurement of water samples containing fluoride in the range of 0.1 ppm to 4.0 ppm. This information should be valuable to dental clinics or laboratories in fluoride analysis of drinking water samples.
Carvalho, Ana P; Malcata, F Xavier
2005-06-29
Assays for fatty acid composition in biological materials are commonly carried out by gas chromatography, after conversion of the lipid material into the corresponding methyl esters (FAME) via suitable derivatization reactions. Quantitative derivatization depends on the type of catalyst and processing conditions employed, as well as the solubility of said sample in the reaction medium. Most literature pertinent to derivatization has focused on differential comparison between alternative methods; although useful to find out the best method for a particular sample, additional studies on factors that may affect each step of FAME preparation are urged. In this work, the influence of various parameters in each step of derivatization reactions was studied, using both cod liver oil and microalgal biomass as model systems. The accuracies of said methodologies were tested via comparison with the AOCS standard method, whereas their reproducibility was assessed by analysis of variance of (replicated) data. Alkaline catalysts generated lower levels of long-chain unsaturated FAME than acidic ones. Among these, acetyl chloride and BF(3) were statistically equivalent to each other. The standard method, which involves alkaline treatment of samples before acidic methylation with BF(3), provided equivalent results when compared with acidic methylation with BF(3) alone. Polarity of the reaction medium was found to be of the utmost importance in the process: intermediate values of polarity [e.g., obtained by a 1:1 (v/v) mixture of methanol with diethyl ether or toluene] provided amounts of extracted polyunsaturated fatty acids statistically higher than those obtained via the standard method.
Emwas, Abdul-Hamid; Luchinat, Claudio; Turano, Paola; Tenori, Leonardo; Roy, Raja; Salek, Reza M; Ryan, Danielle; Merzaban, Jasmeen S; Kaddurah-Daouk, Rima; Zeri, Ana Carolina; Nagana Gowda, G A; Raftery, Daniel; Wang, Yulan; Brennan, Lorraine; Wishart, David S
The metabolic composition of human biofluids can provide important diagnostic and prognostic information. Among the biofluids most commonly analyzed in metabolomic studies, urine appears to be particularly useful. It is abundant, readily available, easily stored and can be collected by simple, noninvasive techniques. Moreover, given its chemical complexity, urine is particularly rich in potential disease biomarkers. This makes it an ideal biofluid for detecting or monitoring disease processes. Among the metabolomic tools available for urine analysis, NMR spectroscopy has proven to be particularly well-suited, because the technique is highly reproducible and requires minimal sample handling. As it permits the identification and quantification of a wide range of compounds, independent of their chemical properties, NMR spectroscopy has been frequently used to detect or discover disease fingerprints and biomarkers in urine. Although protocols for NMR data acquisition and processing have been standardized, no consensus on protocols for urine sample selection, collection, storage and preparation in NMR-based metabolomic studies have been developed. This lack of consensus may be leading to spurious biomarkers being reported and may account for a general lack of reproducibility between laboratories. Here, we review a large number of published studies on NMR-based urine metabolic profiling with the aim of identifying key variables that may affect the results of metabolomics studies. From this survey, we identify a number of issues that require either standardization or careful accounting in experimental design and provide some recommendations for urine collection, sample preparation and data acquisition.
Quantitative evaluation of the CEEM soil sampling intercomparison.
Wagner, G; Lischer, P; Theocharopoulos, S; Muntau, H; Desaules, A; Quevauviller, P
2001-01-08
The aim of the CEEM soil project was to compare and to test the soil sampling and sample preparation guidelines used in the member states of the European Union and Switzerland for investigations of background and large-scale contamination of soils, soil monitoring and environmental risk assessments. The results of the comparative evaluation of the sampling guidelines demonstrated that, in soil contamination studies carried out with different sampling strategies and methods, comparable results can hardly be expected. Therefore, a reference database (RDB) was established by the organisers, which acted as a basis for the quantitative comparison of the participants' results. The detected deviations were related to the methodological details of the individual strategies. The comparative evaluation concept consisted of three steps: The first step was a comparison of the participants' samples (which were both centrally and individually analysed) between each other, as well as with the reference data base (RDB) and some given soil quality standards on the level of concentrations present. The comparison was made using the example of the metals cadmium, copper, lead and zinc. As a second step, the absolute and relative deviations between the reference database and the participants' results (both centrally analysed under repeatability conditions) were calculated. The comparability of the samples with the RDB was categorised on four levels. Methods of exploratory statistical analysis were applied to estimate the differential method bias among the participants. The levels of error caused by sampling and sample preparation were compared with those caused by the analytical procedures. As a third step, the methodological profiles of the participants were compiled to concisely describe the different procedures used. They were related to the results to find out the main factors leading to their incomparability. The outcome of this evaluation process was a list of strategies and methods, which are problematic with respect to comparability, and should be standardised and/or specified in order to arrive at representative and comparable results in soil contamination studies throughout Europe. Pre-normative recommendations for harmonising European soil sampling guidelines and standard operating procedures have been outlined in Wagner G, Desules A, Muntau H, Theocharopoulos S. Comparative Evaluation of European Methods for Sampling and Sample Preparation of Soils for Inorganic Analysis (CEEM Soil). Final Report of the Contract SMT4-CT96-2085, Sci Total Environ 2001;264:181-186. Wagner G, Desaules A, Munatu H. Theocharopolous S, Quevauvaller Ph. Suggestions for harmonising sampling and sample pre-treatment procedures and improving quality assurance in pre-analytical steps of soil contamination studies. Paper 1.7 Sci Total Environ 2001b;264:103-118.
Appel, David I.; Brinda, Bryan; Markowitz, John S.; Newcorn, Jeffrey H.; Zhu, Hao-Jie
2012-01-01
A simple, rapid and sensitive method for quantification of atomoxetine by liquid chromatography- tandem mass spectrometry (LC-MS/MS) was developed. This assay represents the first LC-MS/MS quantification method for atomoxetine utilizing electrospray ionization. Deuterated atomoxetine (d3-atomoxetine) was adopted as the internal standard. Direct protein precipitation was utilized for sample preparation. This method was validated for both human plasma and in vitro cellular samples. The lower limit of quantification was 3 ng/ml and 10 nM for human plasma and cellular samples, respectively. The calibration curves were linear within the ranges of 3 ng/ml to 900 ng/ml and 10 nM to 10 μM for human plasma and cellular samples, respectively (r2 > 0.999). The intra- and inter-day assay accuracy and precision were evaluated using quality control samples at 3 different concentrations in both human plasma and cellular lysate. Sample run stability, assay selectivity, matrix effect, and recovery were also successfully demonstrated. The present assay is superior to previously published LC-MS and LC-MS/MS methods in terms of sensitivity or the simplicity of sample preparation. This assay is applicable to the analysis of atomoxetine in both human plasma and in vitro cellular samples. PMID:22275222
NASA Astrophysics Data System (ADS)
Allwood, D. A.; Perera, I. K.; Perkins, J.; Dyer, P. E.; Oldershaw, G. A.
1996-11-01
Highly uniform thin films of samples for matrix-assisted laser desorption/ionisation (MALDI) have been fabricated by depositing a saturated solution of ferulic acid onto a soda lime glass disc and crushing with polished aluminium, the films covering large areas of the substrate and having a thickness between 45-60 μm. The effects that different substrates and crushing materials as well as sample concentration and sample recrystallisation have on these films has been examined by scanning electron microscopy. Such films have been shown to have a lower threshold fluence for matrix ion detection than standard dried-droplet samples, the reduction being approximately 15% for three of the five matrices analysed. An explanation for this is proposed in terms of crushed samples possessing a greater average energy per unit volume coupled to them by the laser due to their improved surface uniformity. Furthermore, samples that are dried at refrigerated temperatures (˜ 2.25°C) are shown to have a much improved macroscopic uniformity over samples dried at room temperature. Refrigerated and crushed MALDI samples yield analyte ions with good spot-to-spot and pulse-to-pulse reproducibility and both preparation steps appear to improve the resolution of spectra obtained with a time-of-flight mass spectrometer.
Ying, William; Levons, Jaquan K; Carney, Andrea; Gandhi, Rajesh; Vydra, Vicky; Rubin, A Erik
2016-06-01
A novel semiautomated buffer exchange process workflow was developed to enable efficient early protein formulation screening. An antibody fragment protein, BMSdab, was used to demonstrate the workflow. The process afforded 60% to 80% cycle time and scientist time savings and significant material efficiencies. These efficiencies ultimately facilitated execution of this stability work earlier in the drug development process, allowing this tool to inform the developability of potential candidates for development from a formulation perspective. To overcome the key technical challenges, the protein solution was buffer-exchanged by centrifuge filtration into formulations for stability screening in a 96-well plate with an ultrafiltration membrane, leveraging automated liquid handling and acoustic volume measurements to allow several cycles of exchanges. The formulations were transferred into a vacuum manifold and sterile filtered into a rack holding 96 glass vials. The vials were sealed with a capmat of individual caps and placed in stability stations. Stability of the samples prepared by this process and by the standard process was demonstrated to be comparable. This process enabled screening a number of formulations of a protein at an early pharmaceutical development stage with a short sample preparation time. © 2015 Society for Laboratory Automation and Screening.
Preparation and evaluation of ageing effect of Cu-Al-Be-Mn shape memory alloys
NASA Astrophysics Data System (ADS)
Shivasiddaramaiah, A. G.; Mallik, U. S.; Mahato, Ranjit; Shashishekar, C.
2018-04-01
10-14 wt. % of aluminum, 0.3-0.6 wt. % of beryllium and 0.1-0.4 wt. % of manganese and remaining copper melted in the induction furnace through ingot metallurgy. The prepared SMAs are subjected to homogenization. It was observed that the samples exhibits β-phase at high temperature and shape memory effect after going through step quenching to a low temperature. Scanning Electron Microscope, DSC, bending test were performed on the samples to determine the microstructure, transformation temperatures and shape memory effect respectively. The alloy exhibit good shape memory effect, up to around 96% strain recovery by shape memory effect. The ageing is performed on the specimen prepared according to ASTM standard for testing micro-hardness and tensile test. Precipitation hardening method was employed to age the samples and they were aged at different temperature and at different times followed by quenching. Various forms of precipitates were formed. It was found that the formation rate and transformation temperature increased with ageing time, while the amount of precipitate had an inverse impact on strain recovery by shape memory effect. The result expected is to increase in mechanical properties of the material such as hardness.
NASA Astrophysics Data System (ADS)
Tang, Jin; Liu, Xiansong; Mehmood Ur Rehman, Khalid; Li, Dan; Li, Mingling; Yang, Yujie
2018-04-01
We report a successful preparation of Ba1-xLaxFe22+Fe163+O27 (x = 0.00-0.10) W-type hexagonal ferrites by standard ceramic method in a reduced oxygen atmosphere. In this work, the effect of the substitution La3+ rare-earth ions for Ba2+ ions on the structural and magnetic properties of the prepared samples have been studied. The phase identification of magnetic powders was performed by X-ray diffraction. The results of XRD show that the single phase was observed in the W-type ferrites with different La content. The SEM micrographs showed that the ferrites have formed the hexagonal structure. The magnetic properties of the samples were metric by a vibrating sample magnetometer. The coercivity (Hc) of the particles decreases with the increase of La content(x), while the saturation magnetization (Ms) of the particles first increases with x from 0 to 0.05, and then begins to decrease when x continues to increase. The monotonic dependence of the magnetic anisotropy field Ha and coercivity Hc on the La3+ doping amount is found to be mainly dominated by the competition between Ms and Keff.
Hoople, Gordon D; Richards, Andrew; Wu, Yan; Pisano, Albert P; Zhang, Kun
2018-03-26
The ability to amplify and sequence either DNA or RNA from small starting samples has only been achieved in the last five years. Unfortunately, the standard protocols for generating genomic or transcriptomic libraries are incompatible and researchers must choose whether to sequence DNA or RNA for a particular sample. Gel-seq solves this problem by enabling researchers to simultaneously prepare libraries for both DNA and RNA starting with 100 - 1000 cells using a simple hydrogel device. This paper presents a detailed approach for the fabrication of the device as well as the biological protocol to generate paired libraries. We designed Gel-seq so that it could be easily implemented by other researchers; many genetics labs already have the necessary equipment to reproduce the Gel-seq device fabrication. Our protocol employs commonly-used kits for both whole-transcript amplification (WTA) and library preparation, which are also likely to be familiar to researchers already versed in generating genomic and transcriptomic libraries. Our approach allows researchers to bring to bear the power of both DNA and RNA sequencing on a single sample without splitting and with negligible added cost.
Establishment of gold-quartz standard GQS-1
Millard, Hugh T.; Marinenko, John; McLane, John E.
1969-01-01
A homogeneous gold-quartz standard, GQS-1, was prepared from a heterogeneous gold-bearing quartz by chemical treatment. The concentration of gold in GQS-1 was determined by both instrumental neutron activation analysis and radioisotope dilution analysis to be 2.61?0.10 parts per million. Analysis of 10 samples of the standard by both instrumental neutron activation analysis and radioisotope dilution analysis failed to reveal heterogeneity within the standard. The precision of the analytical methods, expressed as standard error, was approximately 0.1 part per million. The analytical data were also used to estimate the average size of gold particles. The chemical treatment apparently reduced the average diameter of the gold particles by at least an order of magnitude and increased the concentration of gold grains by a factor of at least 4,000.
Tsai, De-Cheng; Liu, Meng-Chieh; Lin, Yi-Reng; Huang, Mei-Fang; Liang, Shih-Shin
2016-04-15
Garlic (Allium sativum) is a long-cultivated plant that is widely utilized in cooking and has been employed as a medicine for over 4000 years. In this study, we fabricated standards and internal standards (ISs) for absolute quantification via reductive amination with isotopic formaldehydes. Garlic has four abundant organosulfur compounds (OSCs): S-allylcysteine, S-allylcysteinine sulfoxide, S-methylcysteine, and S-ethylcysteine are abundant in garlic. OSCs with primary amine groups were reacted with isotopic formaldehydes to synthesize ISs and standards. Cooked and uncooked garlic samples were compared, and we utilized tandem mass spectrometry equipped with a selective reaction monitoring technique to absolutely quantify the four organosulfur compounds. Copyright © 2015 Elsevier Ltd. All rights reserved.
Quantifying inter-laboratory variability in stable isotope analysis of ancient skeletal remains.
Pestle, William J; Crowley, Brooke E; Weirauch, Matthew T
2014-01-01
Over the past forty years, stable isotope analysis of bone (and tooth) collagen and hydroxyapatite has become a mainstay of archaeological and paleoanthropological reconstructions of paleodiet and paleoenvironment. Despite this method's frequent use across anthropological subdisciplines (and beyond), the present work represents the first attempt at gauging the effects of inter-laboratory variability engendered by differences in a) sample preparation, and b) analysis (instrumentation, working standards, and data calibration). Replicate analyses of a 14C-dated ancient human bone by twenty-one archaeological and paleoecological stable isotope laboratories revealed significant inter-laboratory isotopic variation for both collagen and carbonate. For bone collagen, we found a sizeable range of 1.8‰ for δ13Ccol and 1.9‰ for δ15Ncol among laboratories, but an interpretatively insignificant average pairwise difference of 0.2‰ and 0.4‰ for δ13Ccol and δ15Ncol respectively. For bone hydroxyapatite the observed range increased to a troublingly large 3.5‰ for δ13Cap and 6.7‰ for δ18Oap, with average pairwise differences of 0.6‰ for δ13Cap and a disquieting 2.0‰ for δ18Oap. In order to assess the effects of preparation versus analysis on isotopic variability among laboratories, a subset of the samples prepared by the participating laboratories were analyzed a second time on the same instrument. Based on this duplicate analysis, it was determined that roughly half of the isotopic variability among laboratories could be attributed to differences in sample preparation, with the other half resulting from differences in analysis (instrumentation, working standards, and data calibration). These findings have serious implications for choices made in the preparation and extraction of target biomolecules, the comparison of results obtained from different laboratories, and the interpretation of small differences in bone collagen and hydroxyapatite isotope values. To address the issues arising from inter-laboratory comparisons, we devise a novel measure we term the Minimum Meaningful Difference (MMD), and demonstrate its application.
Quantifying Inter-Laboratory Variability in Stable Isotope Analysis of Ancient Skeletal Remains
Pestle, William J.; Crowley, Brooke E.; Weirauch, Matthew T.
2014-01-01
Over the past forty years, stable isotope analysis of bone (and tooth) collagen and hydroxyapatite has become a mainstay of archaeological and paleoanthropological reconstructions of paleodiet and paleoenvironment. Despite this method's frequent use across anthropological subdisciplines (and beyond), the present work represents the first attempt at gauging the effects of inter-laboratory variability engendered by differences in a) sample preparation, and b) analysis (instrumentation, working standards, and data calibration). Replicate analyses of a 14C-dated ancient human bone by twenty-one archaeological and paleoecological stable isotope laboratories revealed significant inter-laboratory isotopic variation for both collagen and carbonate. For bone collagen, we found a sizeable range of 1.8‰ for δ13Ccol and 1.9‰ for δ15Ncol among laboratories, but an interpretatively insignificant average pairwise difference of 0.2‰ and 0.4‰ for δ13Ccol and δ15Ncol respectively. For bone hydroxyapatite the observed range increased to a troublingly large 3.5‰ for δ13Cap and 6.7‰ for δ18Oap, with average pairwise differences of 0.6‰ for δ13Cap and a disquieting 2.0‰ for δ18Oap. In order to assess the effects of preparation versus analysis on isotopic variability among laboratories, a subset of the samples prepared by the participating laboratories were analyzed a second time on the same instrument. Based on this duplicate analysis, it was determined that roughly half of the isotopic variability among laboratories could be attributed to differences in sample preparation, with the other half resulting from differences in analysis (instrumentation, working standards, and data calibration). These findings have serious implications for choices made in the preparation and extraction of target biomolecules, the comparison of results obtained from different laboratories, and the interpretation of small differences in bone collagen and hydroxyapatite isotope values. To address the issues arising from inter-laboratory comparisons, we devise a novel measure we term the Minimum Meaningful Difference (MMD), and demonstrate its application. PMID:25061843
Zhong, Cheng; He, Man; Liao, Huaping; Chen, Beibei; Wang, Cheng; Hu, Bin
2016-04-08
In this work, covalent triazine frameworks (CTFs) were introduced in stir bar sorptive extraction (SBSE) and a novel polydimethylsiloxane(PDMS)/CTFs stir bar coating was prepared by sol-gel technique for the sorptive extraction of eight phenols (including phenol, 2-chlorophenol, 2-nitrophenol, 4-nitrophenol, 2,4-dimethylphenol, p-chloro-m-cresol and 2,4-dichlorophenol, 2,4,6-trichlorophenol) from environmental water samples followed by high performance liquid chromatography-ultraviolet (HPLC-UV) detection. The prepared PDMS/CTFs coated stir bar showed good preparation reproducibility with the relative standard deviations (RSDs) ranging from 3.5 to 5.7% (n=7) in one batch, and from 3.7 to 9.3% (n=7) among different batches. Several parameters affecting SBSE of eight target phenols including extraction time, stirring rate, sample pH, ionic strength, desorption solvent and desorption time were investigated. Under the optimal experimental conditions, the limits of detection (LODs, S/N=3) were found to be in the range of 0.08-0.30 μg/L. The linear range was 0.25-500 μg/L for 2-nitrophenol, 0.5-500 μg/L for phenol, 2-chlorophenol, 4-nitrophenol as well as 2,4-dimethylphenol, and 1-500 μg/L for p-chloro-m-cresol, 2,4-dichlorophenol as well as 2,4,6-trichlorophenol, respectively. The intra-day relative standard deviations (RSDs) were in the range of 4.3-9.4% (n=7, c=2 μg/L) and the enrichment factors ranged from 64.9 to 145.6 fold (theoretical enrichment factor was 200-fold). Compared with commercial PDMS coated stir bar (Gerstel) and PEG coated stir bar (Gerstel), the prepared PDMS/CTFs stir bar showed better extraction efficiency for target phenol compounds. The proposed method was successfully applied to the analysis of phenols in environmental water samples and good relative recoveries were obtained with the spiking level at 2, 10, 50 μg/L, respectively. Copyright © 2016 Elsevier B.V. All rights reserved.
3D high- and super-resolution imaging using single-objective SPIM.
Galland, Remi; Grenci, Gianluca; Aravind, Ajay; Viasnoff, Virgile; Studer, Vincent; Sibarita, Jean-Baptiste
2015-07-01
Single-objective selective-plane illumination microscopy (soSPIM) is achieved with micromirrored cavities combined with a laser beam-steering unit installed on a standard inverted microscope. The illumination and detection are done through the same objective. soSPIM can be used with standard sample preparations and features high background rejection and efficient photon collection, allowing for 3D single-molecule-based super-resolution imaging of whole cells or cell aggregates. Using larger mirrors enabled us to broaden the capabilities of our system to image Drosophila embryos.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harringa, J.L.; Cook, B.A.
1996-06-01
Improvements to state-of-the-art Si{sub 80}Ge{sub 20} thermoelectric alloys have been observed in laboratory-scale samples by the powder metallurgy techniques of mechanical alloying and hot pressing. Incorporating these improvements in large scale compacts for the production of thermoelectric generator elements is the next step in achieving higher efficiency RTGs. This paper discusses consolidation of large quantities of mechanically alloyed powders into production size compacts. Differences in thermoelectric properties are noted between the compacts prepared by the standard technique of hot uniaxial pressing and hot isostatic pressing. Most significant is the difference in carrier concentration between the alloys prepared by the twomore » consolidation techniques.« less
Qi, Lian-Wen; Yu, Qing-Tao; Yi, Ling; Ren, Mei-Ting; Wen, Xiao-Dong; Wang, Yu-Xia; Li, Ping
2008-01-01
An improved quality control method was developed to simultaneously determine 15 major constituents (eight flavonoids and seven saponins) in various radix Astragali preparations, using SPE for pretreatment of samples, HPLC with diode-array and evaporative light scattering detectors (DAD-ELSD) for quantification in one run, and HPLC-ESI-TOF/MS for definite identification of compounds in preparations. Optimum separations were obtained with a ZORBAX C(18) column, using a gradient elution with 0.3% aqueous formic acid and ACN. This established method was fully validated with respect to linearity, precision, repeatability, and accuracy, and was successfully applied to quantify the 15 compounds in 19 commercial samples, including 3 dosage forms, i. e., oral solution, injection, concentrated granule, and its processed products of radix Astragali. The results demonstrated that many factors might result in significant differences in quality of the final preparations, including crude drugs, pretreatment processes, manufacturing procedure, storage conditions, etc. Then the developed method provided a reasonable and powerful manner to ensure the efficacy, safety, and batch-to-batch uniformity of radix Astragali products by standardizing each procedure, and thus should be proposed as quality control for the clinical use and modernization of herbal preparations.
Standards for reporting qualitative research: a synthesis of recommendations.
O'Brien, Bridget C; Harris, Ilene B; Beckman, Thomas J; Reed, Darcy A; Cook, David A
2014-09-01
Standards for reporting exist for many types of quantitative research, but currently none exist for the broad spectrum of qualitative research. The purpose of the present study was to formulate and define standards for reporting qualitative research while preserving the requisite flexibility to accommodate various paradigms, approaches, and methods. The authors identified guidelines, reporting standards, and critical appraisal criteria for qualitative research by searching PubMed, Web of Science, and Google through July 2013; reviewing the reference lists of retrieved sources; and contacting experts. Specifically, two authors reviewed a sample of sources to generate an initial set of items that were potentially important in reporting qualitative research. Through an iterative process of reviewing sources, modifying the set of items, and coding all sources for items, the authors prepared a near-final list of items and descriptions and sent this list to five external reviewers for feedback. The final items and descriptions included in the reporting standards reflect this feedback. The Standards for Reporting Qualitative Research (SRQR) consists of 21 items. The authors define and explain key elements of each item and provide examples from recently published articles to illustrate ways in which the standards can be met. The SRQR aims to improve the transparency of all aspects of qualitative research by providing clear standards for reporting qualitative research. These standards will assist authors during manuscript preparation, editors and reviewers in evaluating a manuscript for potential publication, and readers when critically appraising, applying, and synthesizing study findings.
Lopes, Nilva P; Collins, Kenneth E; Jardim, Isabel C S F
2003-02-14
Polybutadiene (PBD) has been immobilized on HPLC silica by gamma radiation doses in the range from 5 to 180 kGy. Columns prepared from these reversed-phase materials, as well as from similar non-irradiated materials, were tested with standard sample mixtures and characterized by elemental analysis (% C) and infrared spectroscopy. A low dose of 5 kGy is sufficient to produce a layer of immobilized PBD which functions as an efficient and stable stationary phase. Higher doses give thicker immobilized layers having less favorable chromatographic properties.
Thin-layer chromatography and colorimetric analysis of multi-component explosive mixtures
Pagoria, Philip F.; Mitchell, Alexander R.; Whipple, Richard E.; Carman, M. Leslie
2014-08-26
A thin-layer chromatography method for detection and identification of common military and peroxide explosives in samples includes the steps of provide a reverse-phase thin-layer chromatography plate; prepare the plate by marking spots on which to deposit the samples by touching the plate with a marker; spot one micro liter of a first standard onto one of the spots, spot one micro liter of a second standard onto another of the spots, and spot samples onto other of spots producing a spotted plate; add eluent to a developing chamber; add the spotted plate to the developing chamber; remove the spotted plate from the developing chamber producing a developed plate; place the developed plate in an ultraviolet light box; add a visualization agent to a dip tank; dip the developed plate in the dip tank and remove the developed plate quickly; and detect explosives by viewing said developed plate.
Routine sampling and the control of Legionella spp. in cooling tower water systems.
Bentham, R H
2000-10-01
Cooling water samples from 31 cooling tower systems were cultured for Legionella over a 16-week summer period. The selected systems were known to be colonized by Legionella. Mean Legionella counts and standard deviations were calculated and time series correlograms prepared for each system. The standard deviations of Legionella counts in all the systems were very large, indicating great variability in the systems over the time period. Time series analyses demonstrated that in the majority of cases there was no significant relationship between the Legionella counts in the cooling tower at time of collection and the culture result once it was available. In the majority of systems (25/28), culture results from Legionella samples taken from the same systems 2 weeks apart were not statistically related. The data suggest that determinations of health risks from cooling towers cannot be reliably based upon single or infrequent Legionella tests.
Green banana pasta: an alternative for gluten-free diets.
Zandonadi, Renata Puppin; Botelho, Raquel Braz Assunção; Gandolfi, Lenora; Ginani, Janini Selva; Montenegro, Flávio Martins; Pratesi, Riccardo
2012-07-01
The objective of this study was to develop and analyze a gluten-free pasta made with green banana flour. The study was divided into five steps: preparation/selection, chemical, sensory, technological, and statistical analysis. The modified sample presented greater acceptance (84.5% for celiac individuals and 61.2% for nonceliac) than standard samples (53.6% for nonceliac individuals). There was no significant difference between the modified and the standard samples in terms of appearance, aroma, flavor, and overall quality. The modified pastas presented approximately 98% less lipids. Green bananas are considered a subproduct of low commercial value with little industrial use. The possibility of developing gluten-free products with green banana flour can expand the product supply for people with celiac disease and contribute to a more diverse diet. Copyright © 2012 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Sagdeo, P. R.; Anwar, Shahid; Lalla, N. P.; Patil, S. I.
2006-11-01
In the present study we report the precise resistivity measurements for the polycrystalline bulk sample as well as highly oriented thin-films of La 0.8Ca 0.2MnO 3. The poly crystalline sample was prepared by standard solid-state reaction route and the oriented thin film was prepared by pulsed laser deposition (PLD). The phase purity of these samples was confirmed by X-ray diffraction and the back-scattered electron imaging using scanning electron microscopy (SEM). The oxygen stoichiometry analysis was done by iodimetry titration. The resistivities of these samples were carried out with four-probe resistivity measurement setup. The observed temperature dependence of resistivity data for both the samples was fitted using the polaron model. We have found that polaronic model fits well with the experimental data of both polycrystalline and single crystal samples. A new phenomenological model is proposed and used to estimate contribution to the resistivity due to grain boundary in the ferromagnetic state of polycrystalline manganites and it has been shown that the scattering of electrons from the grain boundary (grain surface) is a function of temperature and controlled by the effective grain resistance at that temperature.
Belsey, Natalie A; Cant, David J H; Minelli, Caterina; Araujo, Joyce R; Bock, Bernd; Brüner, Philipp; Castner, David G; Ceccone, Giacomo; Counsell, Jonathan D P; Dietrich, Paul M; Engelhard, Mark H; Fearn, Sarah; Galhardo, Carlos E; Kalbe, Henryk; Won Kim, Jeong; Lartundo-Rojas, Luis; Luftman, Henry S; Nunney, Tim S; Pseiner, Johannes; Smith, Emily F; Spampinato, Valentina; Sturm, Jacobus M; Thomas, Andrew G; Treacy, Jon P W; Veith, Lothar; Wagstaffe, Michael; Wang, Hai; Wang, Meiling; Wang, Yung-Chen; Werner, Wolfgang; Yang, Li; Shard, Alexander G
2016-10-27
We report the results of a VAMAS (Versailles Project on Advanced Materials and Standards) inter-laboratory study on the measurement of the shell thickness and chemistry of nanoparticle coatings. Peptide-coated gold particles were supplied to laboratories in two forms: a colloidal suspension in pure water and; particles dried onto a silicon wafer. Participants prepared and analyzed these samples using either X-ray photoelectron spectroscopy (XPS) or low energy ion scattering (LEIS). Careful data analysis revealed some significant sources of discrepancy, particularly for XPS. Degradation during transportation, storage or sample preparation resulted in a variability in thickness of 53 %. The calculation method chosen by XPS participants contributed a variability of 67 %. However, variability of 12 % was achieved for the samples deposited using a single method and by choosing photoelectron peaks that were not adversely affected by instrumental transmission effects. The study identified a need for more consistency in instrumental transmission functions and relative sensitivity factors, since this contributed a variability of 33 %. The results from the LEIS participants were more consistent, with variability of less than 10 % in thickness and this is mostly due to a common method of data analysis. The calculation was performed using a model developed for uniform, flat films and some participants employed a correction factor to account for the sample geometry, which appears warranted based upon a simulation of LEIS data from one of the participants and comparison to the XPS results.
Bouche, Marie-Paule L A; Lambert, Willy E; Van Bocxlaer, Jan F P; Piette, Michel H; De Leenheer, André P
2002-01-01
This report describes a fully elaborated and validated method for quantitation of the hydrocarbons n-propane, iso-butane, and n-butane in blood samples. The newly developed analytical procedure is suitable for both emergency cases and forensic medicine investigations. Its practical applicability is illustrated with a forensic blood sample after acute inhalative intoxication with lighter fluid; case history and toxicological findings are included. Identification and quantitation of the analytes were performed using static headspace extraction combined with gas chromatography-mass spectrometry. In order to reconcile the large gas volumes injected (0.5 mL) with the narrowbore capillary column and thus achieve preconcentration, cold trapping on a Tenax sorbent followed by flash desorption was applied. Adequate retention and separation were achieved isothermally at 35 degrees C on a thick-film capillary column. Sample preparation was kept to a strict minimum and involved simply adding 2.5 microL of a liquid solution of 1,1,2-trichlorotrifluoroethane in t-butyl-methylether as an internal standard to aliquots of blood in a capped vial. Standards were created by volumetric dilution departing from a gravimetrically prepared calibration gas mixture composed of 0.3% of n-propane, 0.7% of iso-butane, and 0.8% of n-butane in nitrogen. In the forensic blood sample, the following concentrations were measured: 90.0 microg/L for n-propane, 246 microg/L for iso-butane, and 846 microg/L for n-butane.
NASA Astrophysics Data System (ADS)
Ali, Nauman; Ismail, Muhammad; Khan, Adnan; Khan, Hamayun; Haider, Sajjad; Kamal, Tahseen
2018-01-01
In this work, we have developed simple, sensitive and inexpensive methods for the spectrophotometric determination of urea in urine samples using silver nanoparticles (AgNPs). The standard addition and 2nd order derivative methods were adopted for this purpose. AgNPs were prepared by chemical reduction of AgNO3 with hydrazine using 1,3-di-(1H-imidazol-1-yl)-2-propanol (DIPO) as a stabilizing agent in aqueous medium. The proposed methods were based on the complexation of AgNPs with urea. Using this concept, urea in the urine samples was successfully determined spectrophotometric methods. The results showed high percent recovery with ± RSD. The recoveries of urea in the three urine samples by spectrophotometric standard addition were 99.2% ± 5.37, 96.3% ± 4.49, 104.88% ± 4.99 and that of spectrophotometric 2nd order derivative method were 115.3% ± 5.2, 103.4% ± 2.6, 105.93% ± 0.76. The results show that these methods can open doors for a potential role of AgNPs in the clinical determination of urea in urine, blood, biological, non-biological fluids.
Peng, Jun; Xiao, Deli; He, Hua; Zhao, Hongyan; Wang, Cuixia; Shi, Tian; Shi, Kexin
2016-01-01
In this study, molecularly imprinting technology and stir bar absorption technology were combined to develop a microextraction approach based on a molecularly imprinted polymeric stir bar. The molecularly imprinted polymer stir bar has a high performance, is specific, economical, and simple to prepare. The obtained naftopidil-imprinted polymer-coated bars could simultaneously agitate and adsorb naftopidil in the sample solution. The ratio of template/monomer/cross-linker and conditions of template removal were optimized to prepare a stir bar with highly efficient adsorption. Fourier transform infrared spectroscopy, scanning electron microscopy, selectivity, and extraction capacity experiments showed that the molecularly imprinted polymer stir bar was prepared successfully. To utilize the molecularly imprinted polymer stir bar for the determination of naftopidil in complex body fluid matrices, the extraction time, stirring speed, eluent, and elution time were optimized. The limits of detection of naftopidil in plasma and urine sample were 7.5 and 4.0 ng/mL, respectively, and the recoveries were in the range of 90-112%. The within-run precision and between-run precision were acceptable (relative standard deviation <7%). These data demonstrated that the molecularly imprinted polymeric stir bar based microextraction with high-performance liquid chromatography was a convenient, rapid, efficient, and specific method for the precise determination of trace naftopidil in clinical analysis. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
ERIC Educational Resources Information Center
Young, Dallin George; Dean, Laura A.
2015-01-01
The standards for Master's Level Student Affairs Professional Preparation Programs, first published in 1986, were among the first standards published by the Council for the Advancement of Standards in Higher Education (CAS; Ebbers & Kruempel, 1992). With the latest revision in 2012, the CAS standards for preparation of student affairs…
A field instrument for quantitative determination of beryllium by activation analysis
Vaughn, William W.; Wilson, E.E.; Ohm, J.M.
1960-01-01
A low-cost instrument has been developed for quantitative determinations of beryllium in the field by activation analysis. The instrument makes use of the gamma-neutron reaction between gammas emitted by an artificially radioactive source (Sb124) and beryllium as it occurs in nature. The instrument and power source are mounted in a panel-type vehicle. Samples are prepared by hand-crushing the rock to approximately ?-inch mesh size and smaller. Sample volumes are kept constant by means of a standard measuring cup. Instrument calibration, made by using standards of known BeO content, indicates the analyses are reproducible and accurate to within ? 0.25 percent BeO in the range from 1 to 20 percent BeO with a sample counting time of 5 minutes. Sensitivity of the instrument maybe increased somewhat by increasing the source size, the sample size, or by enlarging the cross-sectional area of the neutron-sensitive phosphor normal to the neutron flux.
Li, Po-Chien; Jiang, Shiuh-Jen
2006-07-01
Ultrasonic slurry sampling electrothermal vaporization dynamic reaction cell inductively coupled plasma mass spectrometry (USS-ETV-DRC-ICP-MS) for the determination of Cr, Cd and Pb in several plastic samples, using NH4NO3 as the modifier, is described. The influences of the instrumental operating conditions and the slurry preparation technique on the ion signals are investigated. A reduction in the intensity of the background at signals corresponding to chromium masses (arising from matrix elements) was achieved by using NH3 as the reaction cell gas in the DRC. The method was applied to determine Cr, Cd and Pb in two polystyrene (PS) samples and a polyvinyl chloride (PVC) sample using two different calibration methods, namely standard addition and isotope dilution. The results were in good agreement with those for digested samples analyzed by ultrasonic nebulization DRC-ICP-MS. The precision between sample replicates was better than 17% with the USS-ETV-DRC-ICP-MS method. The method detection limits, estimated from standard addition curves, were about 6-9, 1-2 and 8-11 ng g(-1) for Cr, Cd and Pb, respectively, in the original plastic samples.
PILOT STUDY: CCQM-P43: Tributyltin and dibutyltin in sediment
NASA Astrophysics Data System (ADS)
Wolff Briche, Céline S. J.; Wahlen, Raimund; Sturgeon, Ralph E.
2006-01-01
The pilot study CCQM P43 was undertaken to allow the assessment of the current capabilities of interested National Metrology Institutes (NIMs) (those which are members of the CCQM) and selected outside 'expert' laboratories for quantification of (C4H9)2Sn+ (DBT) and (C4H9)3Sn+ (TBT) in a prepared marine sediment. It was organised in parallel to the key comparison CCQM-K28, in which only NMIs determined TBT. This exercise was sanctioned by the 8th CCQM meeting, 18-19 April 2002, as an activity of the Inorganic Analysis Working Group and was jointly coordinated by the Institute for National Measurement Standards of the National Research Council of Canada (NRC) and LGC, UK. A total of 13 laboratories initially indicated interest (nine NMIs and four external laboratories). Only one external laboratory utilised a standard calibration approach based on natural abundance TBT and DBT standards, whereas all NMIs relied on isotope dilution mass spectrometry for quantitation (one NMI used ID-MS and an internal standard approach for the analysis of DBT). For this purpose, species specific 117Sn-enriched TBT and DBT standards were supplied by LGC. No sample preparation methodology was prescribed by the coordinating laboratories and, as a consequence, a variety of approaches was adopted by the participants, including mechanical shaking, sonication, accelerated solvent extraction, microwave assisted extraction and heating in combination with Grignard derivatization, ethylation and direct sampling. Detection techniques included ICP-MS (coupled to GC or HPLC), GC-MS and GC-AED. Main text. To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the Mutual Recognition Arrangement (MRA).
Closed tubes preparation of graphite for high-precision AMS radiocarbon analysis
NASA Astrophysics Data System (ADS)
Hajdas, I.; Michczynska, D.; Bonani, G.; Maurer, M.; Wacker, L.
2009-04-01
Radiocarbon dating is an established tool applied in Geochronology. Technical developments of Accelerator Mass Spectrometry AMS, which allow measurements of samples containing less than 1 mg of carbon, opened opportunities for new applications. Moreover, high resolution records of the past changes require high-resolution chronologies i.e. sampling for 14C dating. In result, the field of applications is rapidly expanding and number of radiocarbon analysis is growing rapidly. Nowadays dedicated 14C AMS machines have great capacity for analysis but in order to keep up with the demand for analysis and provide the results as fast as possible a very efficient way of sample preparation is required. Sample preparation for 14C AMS analysis consists of two steps: separation of relevant carbon from the sample material (removing contamination) and preparation of graphite for AMS analysis. The last step usually involves reaction of CO2 with H2, in the presence of metal catalyst (Fe or Co) of specific mesh size heated to 550-625°C, as originally suggested by Vogel et al. (1984). Various graphitization systems have been built in order to fulfil the requirement of sample quality needed for high-precision radiocarbon data. In the early 90ties another method has been proposed (Vogel 1992) and applied by few laboratories mainly for environmental or biomedical samples. This method uses TiH2 as a source of H2 and can be easily and flexibly applied to produce graphite. Sample of CO2 is frozen in to the tube containing pre-conditioned Zn/TiH2 and Fe catalyst. Torch sealed tubes are then placed in the stepwise heated oven at 500/550°C and left to react for several hours. The greatest problem is the lack of control of the reaction completeness and considerable fractionation. However, recently reported results (Xu et al. 2007) suggest that high precision dating using graphite produced in closed tubes might be possible. We will present results of radiocarbon dating of the set of standards and secondary IAEA standards to demonstrate to what level this method can be used for high precision radiocarbon dating. References Vogel JS. 1992. Rapid Production of Graphite without Contamination for Biomedical Ams. Radiocarbon 34: 344-350. Vogel JS, Southon JR, Nelson DE, and Brown TA. 1984. Performance of Catalytically Condensed Carbon for Use in Accelerator Mass-Spectrometry. Nuclear Instruments & Methods in Physics Research Section B-Beam Interactions with Materials and Atoms 233: 289-293. Xu X, Trumbore SE, Zheng S, Southon JR, McDuffee KE, Luttgen M, and Liu JC. 2007. Modifying a sealed tube zinc reduction method for preparation of AMS graphite targets: Reducing background and attaining high precision. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms Accelerator Mass Spectrometry - Proceedings of the Tenth International Conference on Accelerator Mass Spectrometry 259: 320-329.
NASA Astrophysics Data System (ADS)
Venkatachalaiah, K. N.; Nagabhushana, H.; Darshan, G. P.; Basavaraj, R. B.; Daruka Prasad, B.; Sharma, S. C.
2017-09-01
Modified sonochemical route was used to prepare Y2O3:Tm3+ (1-11 mol%) nanophosphor using Mimosa pudica (M.P.) leaves extract as bio-surfactant. The prepared samples were exhibited high crystalline nature with various morphologies. This was due to sonochemical experimental reaction took place between cavitation bubbles and nearby solution. The average crystallite sizes of the prepared samples were about 15 nm to 21 nm as obtained from PXRD and TEM analysis. The ultraviolet visible absorption spectra showed prominent bands with an energy gap varied from 5.73 eV to 5.84 eV. Photoluminescence (PL) emission spectra shows the prominent blue light emission peak at 456 nm attributed to 1D2 → 3F4 transitions of Tm3+ ions. Judd-Ofelt intensity parameters were estimated by using PL emission spectra. The photometric characteristics of the prepared compounds were very close to the blue color of NTSC standards. So the results were fruitful in making use of Y2O3:Tm3 + nanophosphor as an alternative material for effective blue component in WLED's.
NASA Astrophysics Data System (ADS)
Nesic, M.; Popovic, M.; Rabasovic, M.; Milicevic, D.; Suljovrujic, E.; Markushev, D.; Stojanovic, Z.
2018-02-01
In this work, thermal diffusivity of crystalline high-density polyethylene samples of various thickness, and prepared using different procedures, was evaluated by transmission gas-microphone frequency photoacoustics. The samples' composition analysis and their degree of crystallinity were determined from the wide-angle X-ray diffraction, which confirmed that high-density polyethylene samples, obtained by slow and fast cooling, were equivalent in composition but with different degrees of crystallinity. Structural analysis, performed by differential scanning calorimetry, demonstrated that all of the used samples had different levels of crystallinity, depending not only on the preparing procedure, but also on sample thickness. Therefore, in order to evaluate the samples' thermal diffusivity, it was necessary to modify standard photoacoustic fitting procedures (based on the normalization of photoacoustic amplitude and phase characteristics on two thickness levels) for the interpretation of photoacoustic measurements. The calculated values of thermal diffusivity were in the range of the expected literature values. Besides that, the obtained results indicate the unexpected correlation between the values of thermal diffusivity and thermal conductivity with the degree of crystallinity of the investigated geometrically thin samples. The results indicate the necessity of additional investigation of energy transport in macromolecular systems, as well as the possible employment of the photoacoustic techniques in order to clarify its mechanism.
Stojković, Ivana; Todorović, Nataša; Nikolov, Jovana; Tenjović, Branislava
2016-06-01
A procedure for the (222)Rn determination in aqueous samples using liquid scintillation counting (LSC) was evaluated and optimized. Measurements were performed by ultra-low background spectrometer Quantulus 1220™ equipped with PSA (Pulse Shape Analysis) circuit which discriminates alpha/beta spectra. Since calibration procedure is carried out with (226)Ra standard, which has both alpha and beta progenies, it is clear that PSA discriminator has vital importance in order to provide precise spectra separation. Improvement of calibration procedure was done through investigation of PSA discriminator level and, consequentially, the activity of (226)Ra calibration standard influence on (222)Rn efficiency detection. Quench effects on generated spectra i.e. determination of radon efficiency detection were also investigated with quench calibration curve obtained. Radon determination in waters based on modified procedure according to the activity of (226)Ra standard used, dependent on PSA setup, was evaluated with prepared (226)Ra solution samples and drinking water samples with assessment of measurement uncertainty variation included. Copyright © 2016 Elsevier Ltd. All rights reserved.
Gosselin, Robert C; Adcock, Dorothy M; Bates, Shannon M; Douxfils, Jonathan; Favaloro, Emmanuel J; Gouin-Thibault, Isabelle; Guillermo, Cecilia; Kawai, Yohko; Lindhoff-Last, Edelgard; Kitchen, Steve
2018-03-01
This guidance document was prepared on behalf of the International Council for Standardization in Haematology (ICSH) for providing haemostasis-related guidance documents for clinical laboratories. This inaugural coagulation ICSH document was developed by an ad hoc committee, comprised of international clinical and laboratory direct acting oral anticoagulant (DOAC) experts. The committee developed consensus recommendations for laboratory measurement of DOACs (dabigatran, rivaroxaban, apixaban and edoxaban), which would be germane for laboratories assessing DOAC anticoagulation. This guidance document addresses all phases of laboratory DOAC measurements, including pre-analytical (e.g. preferred time sample collection, preferred sample type, sample stability), analytical (gold standard method, screening and quantifying methods) and post analytical (e.g. reporting units, quality assurance). The committee addressed the use and limitations of screening tests such as prothrombin time, activated partial thromboplastin time as well as viscoelastic measurements of clotting blood and point of care methods. Additionally, the committee provided recommendations for the proper validation or verification of performance of laboratory assays prior to implementation for clinical use, and external quality assurance to provide continuous assessment of testing and reporting method. Schattauer GmbH Stuttgart.
[Study on quality standard of Sophora flavescens root extract].
Zhao, Feng-chun; Li, Hao; Chen, Liang-mian; Gao, Hui-min; Zhang, Qi-wei; Wang, Zhi-min; Wu, Pi-e
2015-01-01
As a part of the project for the Chinese Pharmacopoeia (2015 edition), the quality standard of Sophora flavescens root extract was investigated and established. According to the methods described in the Appendix of Chinese Pharmacopoeia (2010 edition), the water and ash inspections were carried out. The marker components trifolirhizin, sophoraflavanone G, oxymatrine and oxysophocarpine in the samples were identified by qualitative TLC. The determination of oxymatrine, matrine, oxysophocarpine and sophocarpine was conducted by HPLC and the total flavonoids were measured by ultraviolet spectrophotometry, using sophoraflavanone G as reference substance. The results indicated the spots on the plate were clear with good resolution and the contents of oxymatrine, matrine, oxysophocarpine and sophocarpine in the 13 batches of the samples were 3.87% - 11.1%, 0.970% - 4.33%, 1.30% - 2.59% and 0.260% - 1.14%, respectively. The total flavoids in the 13 batches of the samples were 3.88% - 7.93%. In the study, the validated methods were reproducible and the established quality standard was feasible, which could be used for the quality control of S. flavescens root extract and related preparations.
Sulfuric acid/hydrogen peroxide digestion and colorimetric a collaborative study.
Christians, D K; Aspelund, T G; Brayton, S V; Roberts, L L
1991-01-01
Seven laboratories participated in a collaborative study of a method for determination of phosphorus in meat and meat products. Samples are digested in sulfuric acid and hydrogen peroxide; digestion is complete in approximately 10 min. Phosphorus is determined by colorimetric analysis of a dilute aliquot of the sample digest. The collaborators analyzed 3 sets of blind duplicate samples from each of 6 classes of meat (U.S. Department of Agriculture classifications): smoked ham, water-added ham, canned ham, pork sausage, cooked sausage, and hamburger. The calibration curve was linear over the range of standard solutions prepared (phosphorus levels from 0.05 to 1.00%); levels in the collaborative study samples ranged from 0.10 to 0.30%. Standard deviations for repeatability (sr) and reproducibility (SR) ranged from 0.004 to 0.012 and 0.007 to 0.014, respectively. Corresponding relative standard deviations (RSDr and RSDR, respectively) ranged from 1.70 to 7.28% and 3.50 to 9.87%. Six laboratories analyzed samples by both the proposed method and AOAC method 24.016 (14th Ed.). One laboratory reported results by the proposed method only. Statistical evaluations indicated no significant difference between the 2 methods. The method has been adopted official first action by AOAC.
Cytomegalovirus neutralization by hyperimmune and standard intravenous immunoglobulin preparations.
Planitzer, Christina B; Saemann, Marcus D; Gajek, Hartwig; Farcet, Maria R; Kreil, Thomas R
2011-08-15
Cytomegalovirus (CMV) remains one of the most important pathogens after transplantation, potentially leading to CMV disease, allograft dysfunction, acute, and chronic rejection and opportunistic infections. Immunoglobulin G (IgG) preparations with high antibody titers against CMV are a valuable adjunctive prevention and treatment option for clinicians and apart from standard intravenous immunoglobulin (IVIG), CMV hyperimmune preparations are available. The CMV antibody titer of these preparations is typically determined by Enzyme-linked immunosorbent assay (ELISA), also used for the selection of high titer plasma donors for the production of the CMV Hyperimmune product. However, CMV ELISA titers do not necessarily correlate with CMV antibody function which is determined by virus neutralization tests. CMV antibody titers were determined by both ELISA and virus neutralization assay and the IgG subclass distribution was compared between a CMV hyperimmune licensed in Europe and standard IVIG preparations. Although the expected high CMV IgG ELISA antibody titers were confirmed for three lots of a CMV hyperimmune preparation, the functionally more relevant CMV neutralizing antibody titers were significantly higher for 31 lots of standard IVIG preparations. Moreover, considerably lower IgG3 levels were found for the CMV hyperimmune preparation compared with standard IVIG preparations. The higher functional CMV neutralization titers of standard IVIG preparations and the better availability of these preparations, suggest that these products could be a valuable alternative to the CMV hyperimmune preparation.
Schroeder, A A; Ford, N L; Coil, J M
2017-03-01
To determine whether post space preparation deviated from the root canal preparation in canals filled with Thermafil, GuttaCore or warm vertically compacted gutta-percha. Forty-two extracted human permanent maxillary lateral incisors were decoronated, and their root canals instrumented using a standardized protocol. Samples were divided into three groups and filled with Thermafil (Dentsply Tulsa Dental Specialties, Johnson City, TN, USA), GuttaCore (Dentsply Tulsa Dental Specialties) or warm vertically compacted gutta-percha, before post space preparation was performed with a GT Post drill (Dentsply Tulsa Dental Specialties). Teeth were scanned using micro-computed tomography after root filling and again after post space preparation. Scans were examined for number of samples with post space deviation, linear deviation of post space preparation and minimum root thickness before and after post space preparation. Parametric data were analysed with one-way analysis of variance (anova) or one-tailed paired Student's t-tests, whilst nonparametric data were analysed with Fisher's exact test. Deviation occurred in eight of forty-two teeth (19%), seven of fourteen from the Thermafil group (50%), one of fourteen from the GuttaCore group (7%), and none from the gutta-percha group. Deviation occurred significantly more often in the Thermafil group than in each of the other two groups (P < 0.05). Linear deviation of post space preparation was greater in the Thermafil group than in both of the other groups and was significantly greater than that of the gutta-percha group (P < 0.05). Minimum root thickness before post space preparation was significantly greater than it was after post space preparation for all groups (P < 0.01). The differences between the Thermafil, GuttaCore and gutta-percha groups in the number of samples with post space deviation and in linear deviation of post space preparation were associated with the presence or absence of a carrier as well as the different carrier materials. © 2016 International Endodontic Journal. Published by John Wiley & Sons Ltd.
Technological developments for strontium-90 determination using AMS
NASA Astrophysics Data System (ADS)
Satou, Yukihiko; Sueki, Keisuke; Sasa, Kimikazu; Matsunaka, Tetsuya; Takahashi, Tsutomu; Shibayama, Nao; Izumi, Daiki; Kinoshita, Norikazu; Matsuzaki, Hiroyuki
2015-10-01
Accelerator mass spectrometry (AMS) is one of method used for 90Sr determination. It would enable rapid 90Sr measurements from environmental samples such as water, soil, and milk. However, routine analysis of 90Sr using AMS has not yet been achieved because of difficulties associated with isobaric separation and production of intense negative ion beams characterized by currents from hundreds of nanoamperes to several microamperes. We have developed a rapid procedure for preparing samples with optimum compositions for use with AMS, which enables production of intense Sr beam currents from an ion source. Samples of SrF2 were prepared from a standard Sr solution and agricultural soil. The time required to prepare a SrF2 sample from a soil sample was 10 h. Negative 88SrF3- ions were successfully extracted at 500 nA from mixed samples of SrF2 and PbF2. In the present work, negative ions of 90Zr, included as an impurity, were accelerated with a tandem accelerator operated at a terminal voltage of 5 MV. Ions characterized by a charge state of 6+ were channeled into a gas counter. An atomic ratio of 90Zr/88Sr of 3 × 10-8 was estimated for the soil sample. No signal was detected from the assay of PbF2, which was pressed in an aluminum cathode, for a mass number of 90. PbF2 revealed good performance in the production of negative SrF3- molecular ion beams and detection of 90Sr with a gas counter.
Preparing School Leaders: Standards-Based Curriculum in the United States
ERIC Educational Resources Information Center
Young, Michelle D.; Anderson, Erin; Nash, Angel Miles
2017-01-01
For the last few decades, leadership standards have served as a de facto "recommended curriculum" for preparation programs in the United States. In this article, we: (1) share the new National Educational Leadership Preparation (NELP) standards, (2) present the literature supporting the standards, and (3) critically assess the influence…
Michen, Benjamin; Geers, Christoph; Vanhecke, Dimitri; Endes, Carola; Rothen-Rutishauser, Barbara; Balog, Sandor; Petri-Fink, Alke
2015-01-01
Standard transmission electron microscopy nanoparticle sample preparation generally requires the complete removal of the suspending liquid. Drying often introduces artifacts, which can obscure the state of the dispersion prior to drying and preclude automated image analysis typically used to obtain number-weighted particle size distribution. Here we present a straightforward protocol for prevention of the onset of drying artifacts, thereby allowing the preservation of in-situ colloidal features of nanoparticles during TEM sample preparation. This is achieved by adding a suitable macromolecular agent to the suspension. Both research- and economically-relevant particles with high polydispersity and/or shape anisotropy are easily characterized following our approach (http://bsa.bionanomaterials.ch), which allows for rapid and quantitative classification in terms of dimensionality and size: features that are major targets of European Union recommendations and legislation. PMID:25965905
Davis, William E; Li, Yongtao
2008-07-15
A new isotope dilution gas chromatography/chemical ionization/tandem mass spectrometric method was developed for the analysis of carcinogenic hydrazine in drinking water. The sample preparation was performed by using the optimized derivatization and multiple liquid-liquid extraction techniques. Using the direct aqueous-phase derivatization with acetone, hydrazine and isotopically labeled hydrazine-(15)N2 used as the surrogate standard formed acetone azine and acetone azine-(15)N2, respectively. These derivatives were then extracted with dichloromethane. Prior to analysis using methanol as the chemical ionization reagent gas, the extract was dried with anhydrous sodium sulfate, concentrated through evaporation, and then fortified with isotopically labeled N-nitrosodimethylamine-d6 used as the internal standard to quantify the extracted acetone azine-(15)N2. The extracted acetone azine was quantified against the extracted acetone azine-(15)N2. The isotope dilution standard calibration curve resulted in a linear regression correlation coefficient (R) of 0.999. The obtained method detection limit was 0.70 ng/L for hydrazine in reagent water samples, fortified at a concentration of 1.0 ng/L. For reagent water samples fortified at a concentration of 20.0 ng/L, the mean recoveries were 102% with a relative standard deviation of 13.7% for hydrazine and 106% with a relative standard deviation of 12.5% for hydrazine-(15)N2. Hydrazine at 0.5-2.6 ng/L was detected in 7 out of 13 chloraminated drinking water samples but was not detected in the rest of the chloraminated drinking water samples and the studied chlorinated drinking water sample.
Scalability, Complexity and Reliability in Quantum Information Processing
2007-03-01
hidden subgroup framework to abelian groups which are not finitely generated. An extension of the basic algorithm breaks the Buchmann-Williams...finding short lattice vectors . In [2], we showed that the generalization of the standard method --- random coset state preparation followed by fourier...sampling --- required exponential time for sufficiently non-abelian groups including the symmetric group , at least when the fourier transforms are
The purpose of this SOP is to describe the general procedures to be followed for cleaning glassware used in preparing and analyzing soil, house dust, air filter, surface wipe, or dermal wash samples for inorganic metals. This procedure was followed to ensure consistent data retr...
Consortia Provide Preview of Common Tests
ERIC Educational Resources Information Center
Gewertz, Catherine
2012-01-01
As teachers begin shaping lessons for the common standards, many are wondering how to prepare their students for tests that won't be ready for at least two years. Sample items being drafted for those exams offer early ideas of what lies ahead. Two large groups of states are using federal Race to the Top money to create new suites of exams for the…
2008-12-01
attached DR1 to a tunable high glass transition temperatue (Tg) polymeric backbone prepared by ROMP. Figure 1. Standard and required poling...approximately 13-15 g of polymer. The remainder of the mixed polymer adhered to screw or barrel. Norbornyl-DR1 monomer (1). 5-norbornene-2- carboxylic acid
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bass, D A; TenKate, L B
Graphite furnace atomic absorption spectrophotometry (GFAAS) is used for determination of ultra-trace metals in environmentally important samples. In the generation of GFAAS calibration curves for many environmental applications, low concentration calibration standards must be prepared dally, as required by the Statement of Work (SOW) for the US Environmental Protection Agency (EPA) Contract Laboratory Program (CLP). This results in significant time and work for the analyst and significant cost to the Analytical Chemistry Laboratory (ACL) for chemicals and waste management. While EPA SW 846 is less prescriptive than the CLP SOW, ACL has been following the CLP guidelines because in-house criteriamore » regarding the stability of GFAAS standards have not been established. A study was conducted to determine the stability of GFAAS standards for analytes commonly used in the ACL (single and mixed) as a function of time. Data were collected over nine months. The results show that GFAAS standards for Sb, Pb, Se, Ag, and TI are stable for a longer period of time than currently assumed by the CLP SOW. Reducing the frequency of preparing these standards will increase efficiency, decrease the handling of hazardous the quantity of hazardous waste generated, and decrease the quantity of hazardous substances to be ordered and stocked by the laboratory. These benefits will improve GFAAS analysis quality, reduce costs, enhance safety, and lower environmental concerns.« less
Riffelmann, M.; Thiel, K.; Schmetz, J.; Wirsing von Koenig, C. H.
2010-01-01
Measuring antibodies to Bordetella pertussis antigens is mostly done by enzyme-linked immunosorbent assays (ELISAs). We compared the performance of ELISA kits that were commercially available in Germany. Eleven measured IgG antibodies, and nine measured IgA antibodies. An in-house ELISA with purified antigens served as a reference method. Samples included two WHO reference preparations, the former Food and Drug Administration (FDA)/Center for Biologics Evaluation and Research (CBER) reference preparations, serum samples from patients with clinically suspected pertussis, and serum samples from patients having received a combined tetanus, diphtheria, and pertussis (Tdap) vaccination. Kits using pertussis toxin (PT) as an antigen showed linearity compared to the WHO Reference preparation (r2 between 0.82 and 0.99), and these kits could quantify antibodies according to the reference preparation. ELISA kits using mixed antigens showed no linear correlation to the reference preparations. Patient results were compared to results of in-house ELISAs using a dual cutoff of either ≥100 IU/ml anti-PT IgG or ≥40 IU/ml anti-PT IgG together with ≥12 IU/ml anti-PT IgA. The sensitivities of kits measuring IgG antibodies ranged between 0.84 and 1.00. The specificities of kits using PT as an antigen were between 0.81 and 0.93. The specificities of kits using mixed antigens were between 0.51 and 0.59 and were thus not acceptable. The sensitivities of kits measuring IgA antibodies ranged between 0.53 and 0.73, and the specificities were between 0.67 and 0.94, indicating that IgA antibodies may be of limited diagnostic value. Our data suggest that ELISAs should use purified PT as an antigen and be standardized to the 1st International Reference preparation. PMID:20943873
Uncertainty propagation for the coulometric measurement of the plutonium concentration in MOX-PU4.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None, None
This GUM WorkbenchTM propagation of uncertainty is for the coulometric measurement of the plutonium concentration in a Pu standard material (C126) supplied as individual aliquots that were prepared by mass. The C126 solution had been prepared and as aliquoted as standard material. Samples are aliquoted into glass vials and heated to dryness for distribution as dried nitrate. The individual plutonium aliquots were not separated chemically or otherwise purified prior to measurement by coulometry in the F/H Laboratory. Hydrogen peroxide was used for valence adjustment. The Pu assay measurement results were corrected for the interference from trace iron in the solutionmore » measured for assay. Aliquot mass measurements were corrected for air buoyancy. The relative atomic mass (atomic weight) of the plutonium from X126 certoficate was used. The isotopic composition was determined by thermal ionization mass spectrometry (TIMS) for comparison but not used in calculations.« less
ANALYSIS OF VAPORS FROM METHYLENE CHLORIDE EXTRACTS OF NUCLEAR GRADE HEPA FILTER FIBERGLASS SAMPLES
DOE Office of Scientific and Technical Information (OSTI.GOV)
FRYE JM; ANASTOS HL; GUTIERREZ FC
2012-06-07
While several organic compounds were detected in the vapor samples used in the reenactment of the preparation of mounts from the extracts of nuclear grade high-efficiency particulate air filter fiberglass samples, the most significant species present in the samples were methylene chloride, phenol, phenol-d6, and 2-fluorophenol. These species were all known to be present in the extracts, but were expected to have evaporated during the preparation of the mounts, as the mounts appeared to be dry before any vapor was collected. These species were present at the following percentages of their respective occupational exposure limits: methylene chloride, 2%; phenol, 0.4%;more » and phenol-d6, 0.6%. However, there is no established limit for 2-fluorophenol. Several other compounds were detected at low levels for which, as in the case of 2-fluorophenol, there are no established permissible exposure limits. These compounds include 2-chlorophenol; N-nitroso-1-propanamine; 2-fluoro-1,1{prime}-biphenyl; 1,2-dihydroacenaphthylene; 2,5-cyclohexadiene-1,4-dione,2,6-bis(1,1-dimethylethyl); trimethyl oxirane; n-propylpropanamine; 2-(Propylamino)ethanol; 4-methoxy-1-butene; 6-methyl-5-hepten-2-one; and 3,4-dimethylpyridine. Some of these were among those added as surrogates or spike standards as part ofthe Advanced Technologies and Laboratories International, Inc. preparation ofthe extract of the HEPA filter media and are indicated as such in the data tables in Section 2, Results; other compounds found were not previously known to be present. The main inorganic species detected (sulfate, sodium, and sulfur) are also consistent with species added in the preparation of the methylene chloride extract of the high-efficiency particulate air sample.« less
[Baking method of Platycladi Cacumen Carbonisatum based on similarity of UPLC fingerprints].
Shan, Mingqiu; Chen, Chao; Yao, Xiaodong; Ding, Anwei
2010-09-01
To establish a baking method of Platycladi Cacumen Carbonisatum for providing a new idea to Carbonic Herbs' research. Samples were prepared in an oven for different time at different temperatures separately. Then the fingerprints of the samples were determined by UPLC. According to the standard fingerprint, the similarities of the samples' fingerprints were compared. The similarities of 3 samples, which were baked at 230 degrees C for 20 min, 30 min and at 240 degrees C for 20 min, were above 0.96. According to the similarities of the fingerprints and in view of the appearances, Platycladi Cacumen Carbonizing should be baked at 230 degrees C for 20 min.
Integrated Multi-process Microfluidic Systems for Automating Analysis
Yang, Weichun; Woolley, Adam T.
2010-01-01
Microfluidic technologies have been applied extensively in rapid sample analysis. Some current challenges for standard microfluidic systems are relatively high detection limits, and reduced resolving power and peak capacity compared to conventional approaches. The integration of multiple functions and components onto a single platform can overcome these separation and detection limitations of microfluidics. Multiplexed systems can greatly increase peak capacity in multidimensional separations and can increase sample throughput by analyzing many samples simultaneously. On-chip sample preparation, including labeling, preconcentration, cleanup and amplification, can all serve to speed up and automate processes in integrated microfluidic systems. This paper summarizes advances in integrated multi-process microfluidic systems for automated analysis, their benefits and areas for needed improvement. PMID:20514343
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nieroda, Pawel; Zybala, Rafal; Wojciechowski, Krzysztof T.
The aim of the study was to develop a fast and simple method for preparation of polycrystalline Mg{sub 2}Si. For this purpose a Spark Plasma Sintering (SPS) method was used and synthesis conditions were adjusted in such a manner that no excess Mg was required. Materials were synthesized by the direct reaction of Mg and Si raw powders. To determine the phase and chemical composition, the fabricated samples were studied by X-ray diffraction and SEM microscopy coupled with EDX chemical analysis. Thermoelectric properties of samples (thermal conductivity, electrical conductivity and Seebeck coefficient) were measured all over temperature range of 300-650more » K. The analysis by the scanning thermoelectric microprobe (STM) shows that samples have uniform distribution of Seebeck coefficient with mean value of about -405 {mu}VK{sup -1} and standard deviation of 94 {mu}VK{sup -1}. Prepared materials have intrinsic band gap of 0.45 eV and thermal conductivity {lambda}= 7.5 Wm{sup -1}K{sup -1} at room temperature.« less
Periat, Aurélie; Kohler, Isabelle; Thomas, Aurélien; Nicoli, Raul; Boccard, Julien; Veuthey, Jean-Luc; Schappler, Julie; Guillarme, Davy
2016-03-25
Reversed phase liquid chromatography (RPLC) coupled to mass spectrometry (MS) is the gold standard technique in bioanalysis. However, hydrophilic interaction chromatography (HILIC) could represent a viable alternative to RPLC for the analysis of polar and/or ionizable compounds, as it often provides higher MS sensitivity and alternative selectivity. Nevertheless, this technique can be also prone to matrix effects (ME). ME are one of the major issues in quantitative LC-MS bioanalysis. To ensure acceptable method performance (i.e., trueness and precision), a careful evaluation and minimization of ME is required. In the present study, the incidence of ME in HILIC-MS/MS and RPLC-MS/MS was compared for plasma and urine samples using two representative sets of 38 pharmaceutical compounds and 40 doping agents, respectively. The optimal generic chromatographic conditions in terms of selectivity with respect to interfering compounds were established in both chromatographic modes by testing three different stationary phases in each mode with different mobile phase pH. A second step involved the assessment of ME in RPLC and HILIC under the best generic conditions, using the post-extraction addition method. Biological samples were prepared using two different sample pre-treatments, i.e., a non-selective sample clean-up procedure (protein precipitation and simple dilution for plasma and urine samples, respectively) and a selective sample preparation, i.e., solid phase extraction for both matrices. The non-selective pretreatments led to significantly less ME in RPLC vs. HILIC conditions regardless of the matrix. On the contrary, HILIC appeared as a valuable alternative to RPLC for plasma and urine samples treated by a selective sample preparation. Indeed, in the case of selective sample preparation, the compounds influenced by ME were different in HILIC and RPLC, and lower and similar ME occurrence was generally observed in RPLC vs. HILIC for urine and plasma samples, respectively. The complementary of both chromatographic modes was also demonstrated, as ME was observed only scarcely for urine and plasma samples when selecting the most appropriate chromatographic mode. Copyright © 2015 Elsevier B.V. All rights reserved.
Kogovšek, P; Hodgetts, J; Hall, J; Prezelj, N; Nikolić, P; Mehle, N; Lenarčič, R; Rotter, A; Dickinson, M; Boonham, N; Dermastia, M; Ravnikar, M
2015-01-01
In Europe the most devastating phytoplasma associated with grapevine yellows (GY) diseases is a quarantine pest, flavescence dorée (FDp), from the 16SrV taxonomic group. The on-site detection of FDp with an affordable device would contribute to faster and more efficient decisions on the control measures for FDp. Therefore, a real-time isothermal LAMP assay for detection of FDp was validated according to the EPPO standards and MIQE guidelines. The LAMP assay was shown to be specific and extremely sensitive, because it detected FDp in all leaf samples that were determined to be FDp infected using quantitative real-time PCR. The whole procedure of sample preparation and testing was designed and optimized for on-site detection and can be completed in one hour. The homogenization procedure of the grapevine samples (leaf vein, flower or berry) was optimized to allow direct testing of crude homogenates with the LAMP assay, without the need for DNA extraction, and was shown to be extremely sensitive. PMID:26146413
NASA Astrophysics Data System (ADS)
Sitnikov, Dmitri G.; Monnin, Cian S.; Vuckovic, Dajana
2016-12-01
The comparison of extraction methods for global metabolomics is usually executed in biofluids only and focuses on metabolite coverage and method repeatability. This limits our detailed understanding of extraction parameters such as recovery and matrix effects and prevents side-by-side comparison of different sample preparation strategies. To address this gap in knowledge, seven solvent-based and solid-phase extraction methods were systematically evaluated using standard analytes spiked into both buffer and human plasma. We compared recovery, coverage, repeatability, matrix effects, selectivity and orthogonality of all methods tested for non-lipid metabolome in combination with reversed-phased and mixed-mode liquid chromatography mass spectrometry analysis (LC-MS). Our results confirmed wide selectivity and excellent precision of solvent precipitations, but revealed their high susceptibility to matrix effects. The use of all seven methods showed high overlap and redundancy which resulted in metabolite coverage increases of 34-80% depending on LC-MS method employed as compared to the best single extraction protocol (methanol/ethanol precipitation) despite 7x increase in MS analysis time and sample consumption. The most orthogonal methods to methanol-based precipitation were ion-exchange solid-phase extraction and liquid-liquid extraction using methyl-tertbutyl ether. Our results help facilitate rational design and selection of sample preparation methods and internal standards for global metabolomics.
Sitnikov, Dmitri G.; Monnin, Cian S.; Vuckovic, Dajana
2016-01-01
The comparison of extraction methods for global metabolomics is usually executed in biofluids only and focuses on metabolite coverage and method repeatability. This limits our detailed understanding of extraction parameters such as recovery and matrix effects and prevents side-by-side comparison of different sample preparation strategies. To address this gap in knowledge, seven solvent-based and solid-phase extraction methods were systematically evaluated using standard analytes spiked into both buffer and human plasma. We compared recovery, coverage, repeatability, matrix effects, selectivity and orthogonality of all methods tested for non-lipid metabolome in combination with reversed-phased and mixed-mode liquid chromatography mass spectrometry analysis (LC-MS). Our results confirmed wide selectivity and excellent precision of solvent precipitations, but revealed their high susceptibility to matrix effects. The use of all seven methods showed high overlap and redundancy which resulted in metabolite coverage increases of 34–80% depending on LC-MS method employed as compared to the best single extraction protocol (methanol/ethanol precipitation) despite 7x increase in MS analysis time and sample consumption. The most orthogonal methods to methanol-based precipitation were ion-exchange solid-phase extraction and liquid-liquid extraction using methyl-tertbutyl ether. Our results help facilitate rational design and selection of sample preparation methods and internal standards for global metabolomics. PMID:28000704
MacDonald, Matthew L.; Ciccimaro, Eugene; Prakash, Amol; Banerjee, Anamika; Seeholzer, Steven H.; Blair, Ian A.; Hahn, Chang-Gyu
2012-01-01
Synaptic architecture and its adaptive changes require numerous molecular events that are both highly ordered and complex. A majority of neuropsychiatric illnesses are complex trait disorders, in which multiple etiologic factors converge at the synapse via many signaling pathways. Investigating the protein composition of synaptic microdomains from human patient brain tissues will yield valuable insights into the interactions of risk genes in many disorders. These types of studies in postmortem tissues have been limited by the lack of proper study paradigms. Thus, it is necessary not only to develop strategies to quantify protein and post-translational modifications at the synapse, but also to rigorously validate them for use in postmortem human brain tissues. In this study we describe the development of a liquid chromatography-selected reaction monitoring method, using a stable isotope-labeled neuronal proteome standard prepared from the brain tissue of a stable isotope-labeled mouse, for the multiplexed quantification of target synaptic proteins in mammalian samples. Additionally, we report the use of this method to validate a biochemical approach for the preparation of synaptic microdomain enrichments from human postmortem prefrontal cortex. Our data demonstrate that a targeted mass spectrometry approach with a true neuronal proteome standard facilitates accurate and precise quantification of over 100 synaptic proteins in mammalian samples, with the potential to quantify over 1000 proteins. Using this method, we found that protein enrichments in subcellular fractions prepared from human postmortem brain tissue were strikingly similar to those prepared from fresh mouse brain tissue. These findings demonstrate that biochemical fractionation methods paired with targeted proteomic strategies can be used in human brain tissues, with important implications for the study of neuropsychiatric disease. PMID:22942359
[Place and type of meals consumed by adults in medium sized cities].
Carús, Juliana Pires; França, Giovanny V A; Barros, Aluísio J D
2014-02-01
To describe the meals consumed by adults living in a midsize city in the South of Brazil, according to the place and preparation. A population-based cross-sectional study was conducted in Pelotas, Southern Brazil, in 2012. The two-stage sampling design used the 2010 census tracts as primary sampling units. Data were collected on the place of meals (at home or out) and on the kind of preparations consumed at home (homemade, snacks, take away food) covering the two days prior to the interview, using a standardized questionnaire. The study included 2,927 adults, of which 59.0% were female, 60.0% were below 50 years of age and 58.0% were in work. Data were collected on 11,581 meals consumed on the two days preceding the interview, 25.0% were consumed outside of the home at lunchtime, and 10.0% at dinnertime. Considering home meals, most participants reported eating food prepared at home at both lunch and dinner. The majority of out-of-home meals (64.0% for lunch and 61.0% for dinner) were consumed in the work place, mostly based on food prepared at home. Individuals eating out of home were mostly male, young and highly educated. The occupational categories that ate at restaurants more often were trade workers, businessmen, teachers and graduate professionals. Despite the changes in eating patterns described in Brazil in recent years, residents of medium-sized towns still mostly eat at home, consuming homemade food. To describe the meals consumed by adults living in a midsize city in the South of Brazil, according to the place and preparation. A population-based cross-sectional study was conducted in Pelotas, Southern Brazil, in 2012. The two-stage sampling design used the 2010 census tracts as primary sampling units. Data were collected on the place of meals (at home or out) and on the kind of preparations consumed at home (homemade, snacks, take away food) covering the two days prior to the interview, using a standardized questionnaire. The study included 2,927 adults, of which 59.0% were female, 60.0% were below 50 years of age and 58.0% were in work. Data were collected on 11,581 meals consumed on the two days preceding the interview, 25.0% were consumed outside of the home at lunchtime, and 10.0% at dinnertime. Considering home meals, most participants reported eating food prepared at home at both lunch and dinner. The majority of out-of-home meals (64.0% for lunch and 61.0% for dinner) were consumed in the work place, mostly based on food prepared at home. Individuals eating out of home were mostly male, young and highly educated. The occupational categories that ate at restaurants more often were trade workers, businessmen, teachers and graduate professionals. Despite the changes in eating patterns described in Brazil in recent years, residents of medium-sized towns still mostly eat at home, consuming homemade food.
Analysis of coke beverages by total-reflection X-ray fluorescence
NASA Astrophysics Data System (ADS)
Fernández-Ruiz, Ramón; von Bohlen, Alex; Friedrich K, E. Josue; Redrejo, M. J.
2018-07-01
The influence of the organic content, sample preparation process and the morphology of the depositions of two types of Coke beverage, traditional and light Coke, have been investigated by mean of Total-reflection X-ray Fluorescence (TXRF) spectrometry. Strong distortions of the nominal concentration values, up to 128% for P, have been detected in the analysis of traditional Coke by different preparation methods. These differences have been correlated with the edge X-ray energies of the elements analyzed being more pronounced for the lighter elements. The influence of the organic content (mainly sugar) was evaluated comparing traditional and light Coke analytical TXRF results. Three sample preparation methods have been evaluated as follows: direct TXRF analysis of the sample only adding internal standard, TXRF analysis after open vessel acid digestion and TXRF analysis after high pressure and temperature microwave-assisted acid digestion. Strong correlations were detected between quantitative results, methods of preparation and energies of the X-ray absorption edges of quantified elements. In this way, a decay behavior for the concentration differences between preparation methods and the energies of the X-ray absorption edges of each element were observed. The observed behaviors were modeled with exponential decay functions obtaining R2 correlation coefficients from 0.989 to 0.992. The strong absorption effect observed, and even possible matrix effect, can be explained by the inherent high organic content of the evaluated samples and also by the morphology and average thickness of the TXRF depositions observed. As main conclusion of this work, the analysis of light elements in samples with high organic content by TXRF, i.e. medical, biological, food or any other organic matrixes should be taken carefully. In any case, the direct analysis is not recommended and a previous microwave-assisted acid digestion, or similar, is mandatory, for the correct elemental quantification by TXRF.
Moran, James; Alexander, Thomas; Aalseth, Craig; Back, Henning; Mace, Emily; Overman, Cory; Seifert, Allen; Freeburg, Wilcox
2017-08-01
Previous measurements have demonstrated the wealth of information that tritium (T) can provide on environmentally relevant processes. We present modifications to sample preparation approaches that enable T measurement by proportional counting on small sample sizes equivalent to 120mg of water and demonstrate the accuracy of these methods on a suite of standardized water samples. We identify a current quantification limit of 92.2 TU which, combined with our small sample sizes, correlates to as little as 0.00133Bq of total T activity. This enhanced method should provide the analytical flexibility needed to address persistent knowledge gaps in our understanding of both natural and artificial T behavior in the environment. Copyright © 2017. Published by Elsevier Ltd.
Moran, James; Alexander, Thomas; Aalseth, Craig; ...
2017-01-26
Previous measurements have demonstrated the wealth of information that tritium (T) can provide on environmentally relevant processes. Here, we present modifications to sample preparation approaches that enable T measurement by proportional counting on small sample sizes equivalent to 120 mg of water and demonstrate the accuracy of these methods on a suite of standardized water samples. We also identify a current quantification limit of 92.2 TU which, combined with our small sample sizes, correlates to as little as 0.00133 Bq of total T activity. Furthermore, this enhanced method should provide the analytical flexibility needed to address persistent knowledge gaps inmore » our understanding of both natural and artificial T behavior in the environment.« less
NASA Astrophysics Data System (ADS)
Rudman, Reuben
1999-06-01
Wiley-VCH: New York, 1998. xxiv + 333 pp. ISBN 0-471-19458-1. $79.95. I would have subtitled this book "All You Ever Wanted To Know about ...Sample Preparation". Although its principal thrust is geared towards the analytical chemist in an X-ray diffraction (XRD) or X-ray fluorescence (XRF) service laboratory, this text will be of use primarily as a reference source in all milieus dealing with undergraduate research projects and advanced laboratory courses in physical and analytical chemistry. It contains dozens of suggestions for preparing randomly oriented small samples of nearly anything. For example, rocks and minerals, soft organics and hard ceramics, radioactive and liquid materials, metals and oils are all treated. As the availability of XRD and XRF equipment has increased, so has the use of these techniques in the teaching schedule. Many undergraduate laboratory and research projects utilizing these methods have been described in the literature and are found in laboratory textbooks. Very often, especially with the increasingly common use of automated computer-controlled instrumentation, sample preparation has become the key experimental technique required for successful data collection. However, it is not always easy to prepare the statistically random distribution of small particles (crystallites) that is required by these methods. A multitude of techniques have been developed over the past 70 years, but many of them have been handed down by word of mouth or are scattered throughout the literature. This book represents an attempt to systematically describe the theory and practice of sample preparation. This excellent guide to the intricacies of sample preparation begins with a description of statistical sampling methods and the principles of grinding techniques. After a discussion of XRF specimen preparation, which includes pressing pellets, fusion methods, crucible selection and handling very small samples, detailed descriptions for handling rocks, minerals, cements, metals, oils, and vegetation [sic] are given. The preparation of XRD samples is described for various diffraction equipment geometries (utilizing both counter and film detectors), including specific information regarding the use of flat specimens and slurries, the use of internal standards, and the effects of crystallite size on the diffraction pattern. Methods for handling ceramics, clays, zeolites, air-sensitive samples, thin films, and plastics are described, along with the special handling requirements for materials to be studied by high-pressure, high-temperature, or low-temperature techniques. One whole chapter is devoted to the equipment used in specimen preparation, including grinders, pulverizers, presses, specimen holders, repair of platinumware, and sources of all types of special equipment. Did you ever want to know where to get a Plattner steel mortar or a micronizing mill or soft-glass capillary tubes with 0.01-mm wall thickness? It's all here in this monograph. The book ends with a good glossary of terms, a general bibliography in addition to the extensive list of references following each of its 9 chapters, and an index. It will be of help in many areas of spectroscopy and analytical chemistry, as well as in XRD and XRF analyses.
Shulman, Stanley A.; Brisson, Michael J.; Howe, Alan M.
2015-01-01
Inductively coupled plasma mass spectrometry (ICP-MS) is becoming more widely used for trace elemental analysis in the occupational hygiene field, and consequently new ICP-MS international standard procedures have been promulgated by ASTM International and ISO. However, there is a dearth of interlaboratory performance data for this analytical methodology. In an effort to fill this data void, an interlaboratory evaluation of ICP-MS for determining trace elements in workplace air samples was conducted, towards fulfillment of method validation requirements for international voluntary consensus standard test methods. The study was performed in accordance with applicable statistical procedures for investigating interlaboratory precision. The evaluation was carried out using certified 37-mm diameter mixed-cellulose ester (MCE) filters that were fortified with 21 elements of concern in occupational hygiene. Elements were spiked at levels ranging from 0.025 to 10 μg filter−1, with three different filter loadings denoted “Low”, “Medium” and “High”. Participating laboratories were recruited from a pool of over fifty invitees; ultimately twenty laboratories from Europe, North America and Asia submitted results. Triplicates of each certified filter with elemental contents at three different levels, plus media blanks spiked with reagent, were conveyed to each volunteer laboratory. Each participant was also provided a copy of the test method which each participant was asked to follow; spiking levels were unknown to the participants. The laboratories were requested to prepare the filters by one of three sample preparation procedures, i.e., hotplate digestion, microwave digestion or hot block extraction, which were described in the test method. Participants were then asked to analyze aliquots of the prepared samples by ICP-MS, and to report their data in units of μg filter−1. Most interlaboratory precision estimates were acceptable for medium- and high-level spikes (RSD <25%), but generally yielded greater uncertainties than were anticipated at the outset of the study. PMID:22038017
Specimen preparation for NanoSIMS analysis of biological materials
NASA Astrophysics Data System (ADS)
Grovenor, C. R. M.; Smart, K. E.; Kilburn, M. R.; Shore, B.; Dilworth, J. R.; Martin, B.; Hawes, C.; Rickaby, R. E. M.
2006-07-01
In order to achieve reliable and reproducible analysis of biological materials by SIMS, it is critical both that the chosen specimen preparation method does not modify substantially the in vivo chemistry that is the focus of the study and that any chemical information obtained can be calibrated accurately by selection of appropriate standards. In Oxford, we have been working with our new Cameca NanoSIMS50 on two very distinct classes of biological materials; the first where the sample preparation problems are relatively undemanding - human hair - but calibration for trace metal analysis is a critical issue and, the second, marine coccoliths and hyperaccumulator plants where reliable specimen preparation by rapid freezing and controlled drying to preserve the distribution of diffusible species is the first and most demanding requirement, but worthwhile experiments on tracking key elements can still be undertaken even when it is clear that some redistribution of the most diffusible ions has occurred.
Morais, Lais S R; Jardim, Isabel C S F
2005-05-06
Titanium oxide-modified silica was prepared by reaction of silica with titanium tetrabutoxide and then was used as support in the preparation of stationary phases with self-immobilized polybutadiene (PBD) and PBD immobilized through microwave radiation. Chromatographic performance of the stationary phases was evaluated in terms of the efficiency (plates/m), asymmetry (A(s)), retention factor (k) and resolution (R(s)) of two standard sample mixtures, one of then containing the basic compound N,N-dimethylaniline. A microwave irradiation of 30 min at 520 W gave the best efficiency (86,500 N m(-1)), greater than that of a 6-day self immobilized phase (69,500 N m(-1)). Self-immobilized stationary phases prepared with bare silica were also studied for comparison. These resulted in lower chromatographic performance, 43,800 N m(-1), when compared to the self-immobilized phase prepared with titanized silica.
Dukić, Lora; Kopčinović, Lara Milevoj; Dorotić, Adrijana; Baršić, Ivana
2016-10-15
Blood gas analysis (BGA) is exposed to risks of errors caused by improper sampling, transport and storage conditions. The Clinical and Laboratory Standards Institute (CLSI) generated documents with recommendations for avoidance of potential errors caused by sample mishandling. Two main documents related to BGA issued by the CLSI are GP43-A4 (former H11-A4) Procedures for the collection of arterial blood specimens; approved standard - fourth edition, and C46-A2 Blood gas and pH analysis and related measurements; approved guideline - second edition. Practices related to processing of blood gas samples are not standardized in the Republic of Croatia. Each institution has its own protocol for ordering, collection and analysis of blood gases. Although many laboratories use state of the art analyzers, still many preanalytical procedures remain unchanged. The objective of the Croatian Society of Medical Biochemistry and Laboratory Medicine (CSMBLM) is to standardize the procedures for BGA based on CLSI recommendations. The Working Group for Blood Gas Testing as part of the Committee for the Scientific Professional Development of the CSMBLM prepared a set of recommended protocols for sampling, transport, storage and processing of blood gas samples based on relevant CLSI documents, relevant literature search and on the results of Croatian survey study on practices and policies in acid-base testing. Recommendations are intended for laboratory professionals and all healthcare workers involved in blood gas processing.
Dukić, Lora; Kopčinović, Lara Milevoj; Dorotić, Adrijana; Baršić, Ivana
2016-01-01
Blood gas analysis (BGA) is exposed to risks of errors caused by improper sampling, transport and storage conditions. The Clinical and Laboratory Standards Institute (CLSI) generated documents with recommendations for avoidance of potential errors caused by sample mishandling. Two main documents related to BGA issued by the CLSI are GP43-A4 (former H11-A4) Procedures for the collection of arterial blood specimens; approved standard – fourth edition, and C46-A2 Blood gas and pH analysis and related measurements; approved guideline – second edition. Practices related to processing of blood gas samples are not standardized in the Republic of Croatia. Each institution has its own protocol for ordering, collection and analysis of blood gases. Although many laboratories use state of the art analyzers, still many preanalytical procedures remain unchanged. The objective of the Croatian Society of Medical Biochemistry and Laboratory Medicine (CSMBLM) is to standardize the procedures for BGA based on CLSI recommendations. The Working Group for Blood Gas Testing as part of the Committee for the Scientific Professional Development of the CSMBLM prepared a set of recommended protocols for sampling, transport, storage and processing of blood gas samples based on relevant CLSI documents, relevant literature search and on the results of Croatian survey study on practices and policies in acid-base testing. Recommendations are intended for laboratory professionals and all healthcare workers involved in blood gas processing. PMID:27812301
NASA Astrophysics Data System (ADS)
Flinders, Bryn; Beasley, Emma; Verlaan, Ricky M.; Cuypers, Eva; Francese, Simona; Bassindale, Tom; Clench, Malcolm R.; Heeren, Ron M. A.
2017-08-01
Matrix-assisted laser desorption/ionization-mass spectrometry imaging (MALDI-MSI) has been employed to rapidly screen longitudinally sectioned drug user hair samples for cocaine and its metabolites using continuous raster imaging. Optimization of the spatial resolution and raster speed were performed on intact cocaine contaminated hair samples. The optimized settings (100 × 150 μm at 0.24 mm/s) were subsequently used to examine longitudinally sectioned drug user hair samples. The MALDI-MS/MS images showed the distribution of the most abundant cocaine product ion at m/z 182. Using the optimized settings, multiple hair samples obtained from two users were analyzed in approximately 3 h: six times faster than the standard spot-to-spot acquisition method. Quantitation was achieved using longitudinally sectioned control hair samples sprayed with a cocaine dilution series. A multiple reaction monitoring (MRM) experiment was also performed using the `dynamic pixel' imaging method to screen for cocaine and a range of its metabolites, in order to differentiate between contaminated hairs and drug users. Cocaine, benzoylecgonine, and cocaethylene were detectable, in agreement with analyses carried out using the standard LC-MS/MS method. [Figure not available: see fulltext.
Testing of the cytotoxic effects of sulfate pulp mill waste waters.
Cernáková, M; Golis, E
1994-01-01
The effect of 22 technological waste water samples and of some standards was tested on bacteria, fungi, chlorococcal algae, flagellata, plant cells, cells of Tubifex tubifex, hamster cells V79 and the fish Lebistes reticulatus. Of these 22 samples, some inhibition of cell life processes was displayed by the black liquor formed in the production of paper pulp and viscose pulp, by the waste solution produced during the preparation of bleaching agents for paper pulp and viscose pulp, and by the residual liquor after hypochlorite treatment of paper pulp.
Larson, S.J.; Capel, P.D.; VanderLoop, A.G.
1996-01-01
Laboratory and quality assurance procedures for the analysis of ground-water samples for herbicides at the Management Systems Evaluation Area near Princeton, Minnesota are described. The target herbicides include atrazine, de-ethylatrazine, de-isopropylatrazine, metribuzin, alachlor, 2,6-diethylaniline, and metolachlor. The analytical techniques used are solid-phase extraction, and analysis by gas chromatography with mass-selective detection. Descriptions of cleaning procedures, preparation of standard solutions, isolation of analytes from water, sample transfer methods, instrumental analysis, and data analysis are included.
Zaĭtsev, E M; Britsina, M V; Bazhanova, I G; Mertsalova, N U; Ozeretskovskaia, M N; Ermolova, E V; Plekhanova, N G; Mikhaĭlova, N A; Kolyshkin, V A; Zverev, V V
2013-01-01
Evaluate standardness of antigenic composition of pertussis component, completeness of sorption of pertussis, diphtheria and tetanus components, specific activity and safety of experimental series ofADTP-vaccine with acellular pertussis component (ADTaP-vaccine). The content of separate antigens (pertussis toxin, filamentous hemagglutinin and agglutinogens 1, 2, 3) in samples of acellular pertussis component of ADTaP-vaccine and completeness of sorption of pertussis component of ADTaP-vaccine were evaluated by using enzyme immunoassay. Completeness of sorption of diphtheria and tetanus components were determined in flocculation reaction and antitoxin-binding reactions, respectively. Protective activity ofADTaP-vaccine was studied in model ofmeningoencephalitis development in mice infected with Bordetella pertussis (strain 18323) neurotropic virulent culture, protective activity oftetanus component - by survival of mice after administration of tetanus toxin, protective activity of diphtheria component - by survival of guinea pigs after administration of diphtheria toxin. Safety of preparations was evaluated in tests of acute and chronic toxicity with carrying out pathomorphologic studies including immature animals. All the studied experimental series ofADTaP-vaccine were standard by content of separate antigens of pertussis microbe. All the ADTaP-vaccine components were completely sorbed on aluminium hydroxide gel. By protective activity ADTaP preparations satisfied the WHO requirements. The preparations were non-toxic in acute and chronic toxicity and did not induce pathomorphologic changes including immature animals. Experimental samples of ADTaP-vaccine by specific activity and safety satisfied WHO requirements.
Axmann, Sonja; Kolar, Veronika; Adler, Andreas; Strnad, Irmengard
2017-11-01
Salmonella can enter animal stocks via feedstuffs, thus posing not only an infection risk for animals, but also threatening to contaminate food of animal origin and finally humans. Salmonella contamination in feedstuffs is still a recurring and serious issue in animal production (especially for the poultry sector), and is regularly detected upon self-monitoring by feed companies (self-checks) and official inspections authorities. Operators within the feed chain in certain cases need to use hygienic condition enhancers, such as organic acids, to improve the quality of feed for animal nutrition, providing additional guarantees for the protection of animal and public health. The present study investigated the efficiencies of five organic acid preparations. The acid products were added to three different feed materials contaminated with Salmonella (contamination occurred by recontamination in the course of the production process) at seven different inclusion rates (1-7%) and analysed after 1, 2, and 7 days' exposure time using culture method (tenfold analysis). A reliable standard was established for defining a successful decontamination under the prevailing test conditions: 10 Salmonella-negative results out of 10 tested samples (0/10: i.e. 0 positive samples and 10 negative samples). The results demonstrated that the tested preparations showed significant differences with regard to the reduction in Salmonella contamination. At an inclusion rate of 7% of the feed materials, two out of five acid preparations showed an insufficient, very small, decontamination effect, whereas two others had a relatively large partial effect. Reliable decontamination was demonstrated only for one acid preparation, however, subject to the use of the highest acid concentration.
This standard operating procedure describes the method used for preparing internal standard, surrogate recovery standard and calibration standard solutions for neutral analytes used for gas chromatography/mass spectrometry analysis.
Garrigues, P; Narbonne, J F; Lafaurie, M; Ribera, D; Lemaire, P; Raoux, C; Michel, X; Salaun, J P; Monod, J L; Romeo, M
1993-11-01
The GICBEM (Groupe Interface Chimie Biologie des Ecosystèmes Marins) program consists of an evaluation of the ecosystem health status in the Mediterranean Sea mainly based on chemical and biochemical approaches. Specific chemical contaminants (polycyclic aromatic hydrocarbons (PAH), polychlorobiphenyls (PCB), heavy metals) in waters, sediments, and related biotransformation indicators in target organisms (mussels, fish) have been selected for a complete survey of the coastal waters. In order to provide an appropriate sampling program for standardization for each sampling cruise, various aspects have been studied: (a) parameters for the choice of the sample sites; (b) ways of collection the samples (waters, sediments, marine organisms); and (c) preparation of the samples for a short term storage on board ship and for further analyses in the ground laboratory. Methods of preparation and storage of the samples are described and could be used to initiate an environmental banking program including both possible retrospective analyses of chemical pollutants and biochemical indicators. Moreover, the correlation between chemicals (PAH) and biochemical (mixed function oxygenase activities) parameters has been studied and this demonstrates the capability of the enzyme activities as reliable pollution biomarkers.
Development and validation of an HPLC–MS/MS method to determine clopidogrel in human plasma
Liu, Gangyi; Dong, Chunxia; Shen, Weiwei; Lu, Xiaopei; Zhang, Mengqi; Gui, Yuzhou; Zhou, Qinyi; Yu, Chen
2015-01-01
A quantitative method for clopidogrel using online-SPE tandem LC–MS/MS was developed and fully validated according to the well-established FDA guidelines. The method achieves adequate sensitivity for pharmacokinetic studies, with lower limit of quantifications (LLOQs) as low as 10 pg/mL. Chromatographic separations were performed on reversed phase columns Kromasil Eternity-2.5-C18-UHPLC for both methods. Positive electrospray ionization in multiple reaction monitoring (MRM) mode was employed for signal detection and a deuterated analogue (clopidogrel-d4) was used as internal standard (IS). Adjustments in sample preparation, including introduction of an online-SPE system proved to be the most effective method to solve the analyte back-conversion in clinical samples. Pooled clinical samples (two levels) were prepared and successfully used as real-sample quality control (QC) in the validation of back-conversion testing under different conditions. The result showed that the real samples were stable in room temperature for 24 h. Linearity, precision, extraction recovery, matrix effect on spiked QC samples and stability tests on both spiked QCs and real sample QCs stored in different conditions met the acceptance criteria. This online-SPE method was successfully applied to a bioequivalence study of 75 mg single dose clopidogrel tablets in 48 healthy male subjects. PMID:26904399
Rosenblum, L; Hieber, T; Morgan, J
2001-01-01
Use of a temperature-programmable preseparation column in the gas chromatographic (GC) injection port permits determination of a wide range of semi-volatile pesticides including organochlorines, organophosphates, triazines, and anilines in fatty composite dietary samples while reducing sample preparation time and solvent consumption. Dietary samples are mixed with diatomaceous earth and are Soxhlet-extracted with an azeotropic solution of hexane and acetone. Sample preparation uses liquid-liquid partitioning over diatomaceous earth followed by normal phase chromatography over partially deactivated alumina. The final cleanup step occurs in a preseparation column in the GC injector, which is able to perform splitless transfer of the analytes to the analytical column and purge 99% of the high molecular weight residue. Detection is performed by GC/mass spectrometry (MS) in the selected ion monitoring mode. Method detection limits were at or below 2 ng/g for 24 of 35 pesticides studied, with recovery between 70 and 125% for 27 pesticides in samples fortified at 10 ng/g. Recovery was not dependent on fat content when measured in laboratory fortified samples containing 1, 5, and 10% fat by weight. Precision over multiple injections was acceptable, with a relative standard deviation of 2.6-15% for 25 analytes.
Saw, Anne; Berenbaum, Howard; Okazaki, Sumie
2013-03-01
The current study examined perceptions of living up to parental expectations (LPE) and personal standards as possible mediators of the relationship between ethnicity and worry in a sample of 836 Asian American and 856 White American college students. Asian Americans reported higher frequency of academic- and family-related worries, but they did not report higher levels of global tendency to worry. Perceptions of LPE of current academic performance and personal standards for preparation for a future career partially explained ethnic differences in frequency of academic worry. Personal standards and perceptions of LPE for respect for the family partially explained ethnic differences in frequency of family worry. The findings highlight the importance of targeting domain-specific personal standards and perceived parental expectations to reduce worry among Asian Americans.
Synthesis and characterization of Zn-Mg ferrite
NASA Astrophysics Data System (ADS)
Singh, Shailndra; Barbar, S. K.; Ram, Sahi
2018-05-01
The Zn-Mg ferrite sample of general formula Zn0.5Mg0.5Fe2O4 have been prepared by standard solid state reaction technique using high purity oxides. X-ray diffraction analysis shows the formation of a zinc-magnesium ferrite cubic phase at room temperature with space group Fd3m. FTIR spectra show two significant absorption bands first at 665.15 cm-1 corresponding to tetrahedral (A) and second band at 434 cm-1 corresponding to octahedral (B) sites of the spinel. Morphology of the sample determined by the SEM measurement and EDS analysis has confirmed the composition of atoms in the sample.
Preparing for chemical terrorism: stability of injectable atropine sulfate.
Schier, Joshua G; Ravikumar, Padinjarekuttu R; Nelson, Lewis S; Heller, Michael B; Howland, Mary Ann; Hoffman, Robert S
2004-04-01
A massive nerve agent attack may rapidly deplete in-date supplies of atropine. The authors considered using atropine beyond its labeled shelf life. The objective was to determine the stability of premixed injectable atropine sulfate samples with different expiration dates. This was an in-vitro study using gas chromatography and mass spectrometry (GC/MS). Four atropine solutions (labeled concentration of 400 microg/mL) ranging from in date to 12 years beyond expiration (exp) and an additional sample of atropine sulfate (labeled concentration of 2,000 microg/mL) obtained from a World War II era autoinjector were assayed for atropine stability. Standards of atropine sulfate and tropine were prepared and quantified by GC/MS. Study samples were prepared by adding a buffer solution to free the base, extracting with an isopropanol/methylene chloride mixture and followed by evaporating the organic layer to dryness. Pentafluoropropionic anhydride and pentafluoropropanol were then added as derivatization reagents. Study samples were heated, the derivitization reagents were evaporated, and the remaining compound was reconstituted in ethyl acetate for injection into the GC/MS. All solutions were clear and colorless. Atropine concentrations were as follows: in date, 252 microg/mL; 2001 exp, 290 microg/mL; 1999 exp, 314 microg/mL; 1990 exp, 398 microg/mL; and WW II specimen, 1,475 microg/mL. Tropine was found in concentrations of <10 microg/mL in all study samples. Significant amounts of atropine were found in all study samples. All samples remained clear and colorless, and no substantial amount of tropine was found in any study sample. Further testing is needed to determine clinical effect.
Hearns, Nigel G R; Laflèche, Denis N; Sandercock, Mark L
2015-05-01
Preparation of a ytterbium-tagged gunshot residue (GSR) reference standard for scanning electron microscopy and energy dispersive X-ray spectroscopic (SEM-EDS) microanalysis is reported. Two different chemical markers, ytterbium and neodymium, were evaluated by spiking the primers of 38 Special ammunition cartridges (no propellant, no projectile) and discharging them onto 12.7 mm diameter aluminum SEM pin stubs. Following SEM-EDS microanalysis, the majority of tri-component particles containing lead, barium, and antimony (PbBaSb) were successfully tagged with the chemical marker. Results demonstrate a primer spiked with 0.75% weight percent of ytterbium nitrate affords PbBaSb particles characteristic of GSR with a ytterbium inclusion efficiency of between 77% and 100%. Reproducibility of the method was verified, and durability of the ytterbium-tagged tri-component particles under repeated SEM-EDS analysis was also tested. The ytterbium-tagged PbBaSb particles impart synthetic traceability to a GSR reference standard and are suitable for analysis alongside case work samples, as a positive control for quality assurance purposes. © 2015 American Academy of Forensic Sciences.
Sample preparation prior to the LC-MS-based metabolomics/metabonomics of blood-derived samples.
Gika, Helen; Theodoridis, Georgios
2011-07-01
Blood represents a very important biological fluid and has been the target of continuous and extensive research for diagnostic, or health and drug monitoring reasons. Recently, metabonomics/metabolomics have emerged as a new and promising 'omics' platform that shows potential in biomarker discovery, especially in areas such as disease diagnosis, assessment of drug efficacy or toxicity. Blood is collected in various establishments in conditions that are not standardized. Next, the samples are prepared and analyzed using different methodologies or tools. When targeted analysis of key molecules (e.g., a drug or its metabolite[s]) is the aim, enforcement of certain measures or additional analyses may correct and harmonize these discrepancies. In omics fields such as those performed by holistic analytical approaches, no such rules or tools are available. As a result, comparison or correlation of results or data fusion becomes impractical. However, it becomes evident that such obstacles should be overcome in the near future to allow for large-scale studies that involve the assaying of samples from hundreds of individuals. In this case the effect of sample handling and preparation becomes very serious, in order to avoid wasting months of work from experts and expensive instrument time. The present review aims to cover the different methodologies applied to the pretreatment of blood prior to LC-MS metabolomic/metabonomic studies. The article tries to critically compare the methods and highlight issues that need to be addressed.
Jeong, In-Seek; Kwak, Byung-Man; Ahn, Jang-Hyuk; Leem, Donggil; Yoon, Taehyung; Yoon, Changyong; Jeong, Jayoung; Park, Jung-Min; Kim, Jin-Man
2012-10-01
In this study, nonheated saponification was employed as a novel, rapid, and easy sample preparation method for the determination of cholesterol in emulsified foods. Cholesterol content was analyzed using gas chromatography with a flame ionization detector (GC-FID). The cholesterol extraction method was optimized for maximum recovery from baby food and infant formula. Under these conditions, the optimum extraction solvent was 10 mL ethyl ether per 1 to 2 g sample, and the saponification solution was 0.2 mL KOH in methanol. The cholesterol content in the products was determined to be within the certified range of certified reference materials (CRMs), NIST SRM 1544 and SRM 1849. The results of the recovery test performed using spiked materials were in the range of 98.24% to 99.45% with an relative standard devitation (RSD) between 0.83% and 1.61%. This method could be used to reduce sample pretreatment time and is expected to provide an accurate determination of cholesterol in emulsified food matrices such as infant formula and baby food. A novel, rapid, and easy sample preparation method using nonheated saponification was developed for cholesterol detection in emulsified foods. Recovery tests of CRMs were satisfactory, and the recoveries of spiked materials were accurate and precise. This method was effective and decreased the time required for analysis by 5-fold compared to the official method. © 2012 Institute of Food Technologists®
Creation of 0.10-cm-1 resolution quantitative infrared spectral libraries for gas samples
NASA Astrophysics Data System (ADS)
Sharpe, Steven W.; Sams, Robert L.; Johnson, Timothy J.; Chu, Pamela M.; Rhoderick, George C.; Guenther, Franklin R.
2002-02-01
The National Institute of Standards and Technology (NIST) and the Pacific Northwest National Laboratory (PNNL) are independently creating quantitative, approximately 0.10 cm-1 resolution, infrared spectral libraries of vapor phase compounds. The NIST library will consist of approximately 100 vapor phase spectra of volatile hazardous air pollutants (HAPs) and suspected greenhouse gases. The PNNL library will consist of approximately 400 vapor phase spectra associated with DOE's remediation mission. A critical part of creating and validating any quantitative work involves independent verification based on inter-laboratory comparisons. The two laboratories use significantly different sample preparation and handling techniques. NIST uses gravimetric dilution and a continuous flowing sample while PNNL uses partial pressure dilution and a static sample. Agreement is generally found to be within the statistical uncertainties of the Beer's law fit and less than 3 percent of the total integrated band areas for the 4 chemicals used in this comparison. There does appear to be a small systematic difference between the PNNL and NIST data, however. Possible sources of the systematic difference will be discussed as well as technical details concerning the sample preparation and the procedures for overcoming instrumental artifacts.
Srivastava, Praveen; Moorthy, Ganesh S.; Gross, Robert; Barrett, Jeffrey S.
2013-01-01
A selective and a highly sensitive method for the determination of the non-nucleoside reverse transcriptase inhibitor (NNRTI), efavirenz, in human plasma has been developed and fully validated based on high performance liquid chromatography tandem mass spectrometry (LC–MS/MS). Sample preparation involved protein precipitation followed by one to one dilution with water. The analyte, efavirenz was separated by high performance liquid chromatography and detected with tandem mass spectrometry in negative ionization mode with multiple reaction monitoring. Efavirenz and 13C6-efavirenz (Internal Standard), respectively, were detected via the following MRM transitions: m/z 314.20243.90 and m/z 320.20249.90. A gradient program was used to elute the analytes using 0.1% formic acid in water and 0.1% formic acid in acetonitrile as mobile phase solvents, at a flow-rate of 0.3 mL/min. The total run time was 5 min and the retention times for the internal standard (13C6-efavirenz) and efavirenz was approximately 2.6 min. The calibration curves showed linearity (coefficient of regression, r>0.99) over the concentration range of 1.0–2,500 ng/mL. The intraday precision based on the standard deviation of replicates of lower limit of quantification (LLOQ) was 9.24% and for quality control (QC) samples ranged from 2.41% to 6.42% and with accuracy from 112% and 100–111% for LLOQ and QC samples. The inter day precision was 12.3% and 3.03–9.18% for LLOQ and quality controls samples, and the accuracy was 108% and 95.2–108% for LLOQ and QC samples. Stability studies showed that efavirenz was stable during the expected conditions for sample preparation and storage. The lower limit of quantification for efavirenz was 1 ng/mL. The analytical method showed excellent sensitivity, precision, and accuracy. This method is robust and is being successfully applied for therapeutic drug monitoring and pharmacokinetic studies in HIV-infected patients. PMID:23755102
Characterization of Lone Pine, California, tremolite asbestos and preparation of research material
Harper, Martin; Van Gosen, Bradley S.; Crankshaw, Owen S; Doorn, Stacy S; Ennis, J. Todd; Harrison, Sara E
2014-01-01
Well-characterized amphibole asbestos mineral samples are required for use as analytical standards and in future research projects. Currently, the National Institute for Standards and Technology Standard Reference Material samples of asbestos are listed as ‘Discontinued’. The National Institute for Occupational Safety and Health (NIOSH) has a goal under the Asbestos Roadmap of locating and characterizing research materials for future use. Where an initial characterization analysis determines that a collected material is appropriate for use as a research material in terms of composition and asbestiform habit, sufficient amounts of the material will be collected to make it publicly available. An abandoned mine near Lone Pine, California, contains a vein of tremolite asbestos, which was the probable source of a reference material that has been available for the past 17 years from the Health and Safety Laboratory (HSL) in the UK. Newly collected fibrous vein material from this mine was analyzed at Research Triangle Institute (RTI International) with some additional analysis by the US Geological Survey’s Denver Microbeam Laboratory. The analysis at RTI International included: (i) polarized light microscopy (PLM) with a determination of principal optical properties; (ii) X-ray diffraction; (iii) transmission electron microscopy, including energy dispersive X-ray spectroscopy and selected-area electron diffraction; and (iv) spindle stage analysis using PLM to determine whether individual fibers and bundles of the samples were polycrystalline or single-crystal cleavage fragments. The overall findings of the study indicated that the material is tremolite asbestos with characteristics substantially similar to the earlier distributed HSL reference material. A larger quantity of material was prepared by sorting, acid-washing and mixing for sub-division into vials of ~10g each. These vials have been transferred from NIOSH to RTI International, from where they can be obtained on request.
Characterization of Lone Pine, California, Tremolite Asbestos and Preparation of Research Material
Harper, Martin; Van Gosen, Bradley; Crankshaw, Owen S.; Doorn, Stacy S.; Ennis, Todd J.; Harrison, Sara E.
2016-01-01
Well-characterized amphibole asbestos mineral samples are required for use as analytical standards and in future research projects. Currently, the National Institute for Standards and Technology Standard Reference Material samples of asbestos are listed as ‘Discontinued’. The National Institute for Occupational Safety and Health (NIOSH) has a goal under the Asbestos Roadmap of locating and characterizing research materials for future use. Where an initial characterization analysis determines that a collected material is appropriate for use as a research material in terms of composition and asbestiform habit, sufficient amounts of the material will be collected to make it publicly available. An abandoned mine near Lone Pine, California, contains a vein of tremolite asbestos, which was the probable source of a reference material that has been available for the past 17 years from the Health and Safety Laboratory (HSL) in the UK. Newly collected fibrous vein material from this mine was analyzed at Research Triangle Institute (RTI International) with some additional analysis by the US Geological Survey’s Denver Microbeam Laboratory. The analysis at RTI International included: (i) polarized light microscopy (PLM) with a determination of principal optical properties; (ii) X-ray diffraction; (iii) transmission electron microscopy, including energy dispersive X-ray spectroscopy and selected-area electron diffraction; and (iv) spindle stage analysis using PLM to determine whether individual fibers and bundles of the samples were polycrystalline or single-crystal cleavage fragments. The overall findings of the study indicated that the material is tremolite asbestos with characteristics substantially similar to the earlier distributed HSL reference material. A larger quantity of material was prepared by sorting, acid-washing and mixing for sub-division into vials of ~10 g each. These vials have been transferred from NIOSH to RTI International, from where they can be obtained on request. PMID:25268000
Code of Federal Regulations, 2011 CFR
2011-07-01
... regulatory agency to prepare a draft standardized permit? 124.204 Section 124.204 Protection of Environment... agency to prepare a draft standardized permit? (a) You must review the Notice of Intent and supporting... protection of human health and the environment. (c) You must prepare your draft permit decision within 120...
Code of Federal Regulations, 2014 CFR
2014-07-01
... regulatory agency to prepare a draft standardized permit? 124.204 Section 124.204 Protection of Environment... agency to prepare a draft standardized permit? (a) You must review the Notice of Intent and supporting... protection of human health and the environment. (c) You must prepare your draft permit decision within 120...
Code of Federal Regulations, 2012 CFR
2012-07-01
... regulatory agency to prepare a draft standardized permit? 124.204 Section 124.204 Protection of Environment... agency to prepare a draft standardized permit? (a) You must review the Notice of Intent and supporting... protection of human health and the environment. (c) You must prepare your draft permit decision within 120...
Code of Federal Regulations, 2013 CFR
2013-07-01
... regulatory agency to prepare a draft standardized permit? 124.204 Section 124.204 Protection of Environment... agency to prepare a draft standardized permit? (a) You must review the Notice of Intent and supporting... protection of human health and the environment. (c) You must prepare your draft permit decision within 120...
Code of Federal Regulations, 2010 CFR
2010-07-01
... regulatory agency to prepare a draft standardized permit? 124.204 Section 124.204 Protection of Environment... agency to prepare a draft standardized permit? (a) You must review the Notice of Intent and supporting... protection of human health and the environment. (c) You must prepare your draft permit decision within 120...
NASA Astrophysics Data System (ADS)
Mota, Mariana F. B.; Gama, Ednilton M.; Rodrigues, Gabrielle de C.; Rodrigues, Guilherme D.; Nascentes, Clésia C.; Costa, Letícia M.
2018-01-01
In this work, a dilute-and-shoot method was developed for Ca, P, S and Zn determination in new and used lubricating oil samples by total reflection X-ray fluorescence (TXRF). The oil samples were diluted with organic solvents followed by addition of yttrium as internal standard and the TXRF measurements were performed after solvent evaporation. The method was optimized using an interlaboratorial reference material. The experimental parameters evaluated were sample volume (50 or 100 μL), measurement time (250 or 500 s) and volume deposited on the quartz glass sample carrier (5 or 10 μL). All of them were evaluated and optimized using xylene, kerosene and hexane. Analytical figures of merit (accuracy, precision, limit of detection and quantification) were used to evaluate the performance of the analytical method for all solvents. The recovery rates varied from 99 to 111% and the relative standard deviation remained between 1.7% and 10% (n = 8). For all elements, the results obtained by applying the new method were in agreement with the certified value. After the validation step, the method was applied for Ca, P, S and Zn quantification in eight new and four used lubricating oil samples, for all solvents. The concentration of the elements in the samples varied in the ranges of 1620-3711 mg L- 1 for Ca, 704-1277 mg L- 1 for P, 2027-9147 mg L- 1 for S, and 898-1593 mg L- 1 for Zn. The association of TXRF with a dilute-and-shoot sample preparation strategy was efficient for Ca, P, S and Zn determination in lubricating oils, presenting accurate results. Additionally, the time required for analysis is short, the reagent volumes are low minimizing waste generation, and the technique does not require calibration curves.
Optimized Setup and Protocol for Magnetic Domain Imaging with In Situ Hysteresis Measurement.
Liu, Jun; Wilson, John; Davis, Claire; Peyton, Anthony
2017-11-07
This paper elaborates the sample preparation protocols required to obtain optimal domain patterns using the Bitter method, focusing on the extra steps compared to standard metallographic sample preparation procedures. The paper proposes a novel bespoke rig for dynamic domain imaging with in situ BH (magnetic hysteresis) measurements and elaborates the protocols for the sensor preparation and the use of the rig to ensure accurate BH measurement. The protocols for static and ordinary dynamic domain imaging (without in situ BH measurements) are also presented. The reported method takes advantage of the convenience and high sensitivity of the traditional Bitter method and enables in situ BH measurement without interrupting or interfering with the domain wall movement processes. This facilitates establishing a direct and quantitative link between the domain wall movement processes-microstructural feature interactions in ferritic steels with their BH loops. This method is anticipated to become a useful tool for the fundamental study of microstructure-magnetic property relationships in steels and to help interpret the electromagnetic sensor signals for non-destructive evaluation of steel microstructures.
Optimized Setup and Protocol for Magnetic Domain Imaging with In Situ Hysteresis Measurement
Liu, Jun; Wilson, John; Davis, Claire; Peyton, Anthony
2017-01-01
This paper elaborates the sample preparation protocols required to obtain optimal domain patterns using the Bitter method, focusing on the extra steps compared to standard metallographic sample preparation procedures. The paper proposes a novel bespoke rig for dynamic domain imaging with in situ BH (magnetic hysteresis) measurements and elaborates the protocols for the sensor preparation and the use of the rig to ensure accurate BH measurement. The protocols for static and ordinary dynamic domain imaging (without in situ BH measurements) are also presented. The reported method takes advantage of the convenience and high sensitivity of the traditional Bitter method and enables in situ BH measurement without interrupting or interfering with the domain wall movement processes. This facilitates establishing a direct and quantitative link between the domain wall movement processes–microstructural feature interactions in ferritic steels with their BH loops. This method is anticipated to become a useful tool for the fundamental study of microstructure–magnetic property relationships in steels and to help interpret the electromagnetic sensor signals for non-destructive evaluation of steel microstructures. PMID:29155796
NASA Astrophysics Data System (ADS)
Tian, Huairu; Peng, Jun; Lv, Tingting; Sun, Chen; He, Hua
2018-01-01
In present study, a stable and magnetic metal-organic framework (MOF) material was synthesized by simple solvothermal method as adsorbent to rapid removal of two organic dyes, the Rhodamine B (RB) and Rhodamine 6G (Rh6G), in water samples. The prepared material showed great characteristics of large surface area (519.86 m2 g-1), excellent magnetic responsivity (35.00 emu g-1) and rapid removal (within 5 min). Maximum adsorption capacities of the magnetic material toward RB and Rh6G were up to 219.78 and 306.75 mg g-1, respectively. Adsorption kinetics suggested the adsorption process met the pseudo-second-order kinetic model. The prepared material could be reused at least 10 times by washing with acetonitrile solution, the relative standard deviation (RSD) of these ten cycles removal efficiency was 4.8%. In conclusion, good chemical inertness, a mechanical/water stability and super-hydrophilicity feature made this MOF a promising adsorbent for targets removal from environmental water sample.
Dołęgowska, Sabina; Gałuszka, Agnieszka; Migaszewski, Zdzisław M
2017-12-01
The main source of rare earth elements (REE) in mosses is atmospheric deposition of particles. Sample treatment operations including shaking, rinsing or washing, which are made in a standard way on moss samples prior to chemical analysis, may lead to removing particles adsorbed onto their tissues. This in turn causes differences in REE concentrations in treated and untreated samples. For the present study, 27 combined moss samples were collected within three wooded areas and prepared for REE determinations by ICP-MS using both manual cleaning by shaking and triple rinsing with deionized water. Higher concentrations of REE were found in manually cleaned samples. The comparison of REE signatures and shale-normalized REE concentration patterns showed that the treatment procedure did not lead to fractionation of REE. All the samples were enriched in medium rare earth elements, and the δMREE factor remained practically unchanged after rinsing. Positive anomalies of Nd, Sm, Eu, Gd, Er and Yb were observed in both, manually cleaned and rinsed samples. For all the elements examined, analytical uncertainty was below 3.0% whereas sample preparation uncertainty computed with ANOVA, RANOVA, modified RANOVA and range statistics methods varied from 3.5 to 29.7%. In most cases the lowest s rprep values were obtained with the modified RANOVA method. Copyright © 2017 Elsevier Ltd. All rights reserved.
Elemental Analysis in Biological Matrices Using ICP-MS.
Hansen, Matthew N; Clogston, Jeffrey D
2018-01-01
The increasing exploration of metallic nanoparticles for use as cancer therapeutic agents necessitates a sensitive technique to track the clearance and distribution of the material once introduced into a living system. Inductively coupled plasma mass spectrometry (ICP-MS) provides a sensitive and selective tool for tracking the distribution of metal components from these nanotherapeutics. This chapter presents a standardized method for processing biological matrices, ensuring complete homogenization of tissues, and outlines the preparation of appropriate standards and controls. The method described herein utilized gold nanoparticle-treated samples; however, the method can easily be applied to the analysis of other metals.
ERIC Educational Resources Information Center
Nyasulu, Frazier; Moehring, Michael; Arthasery, Phyllis; Barlag, Rebecca
2011-01-01
The acid ionization constant, K[subscript a], of acetic acid and the base ionization constant, K[subscript b], of ammonia are determined easily and rapidly using a datalogger, a pH sensor, and a conductivity sensor. To decrease sample preparation time and to minimize waste, sequential aliquots of a concentrated standard are added to a known volume…
A Novel Approach to Assay DNA Methylation in Prostate Cancer
2016-10-01
prepared into libraries according to standard protocols using Bioo Scientific’s DNA Sample Kit (cat. no. 514101, Austin , TX , USA). Libraries were...Medical Research and Materiel Command Fort Detrick, Maryland 21702-5012 DISTRIBUTION STATEMENT: Approved for Public Release; Distribution Unlimited...ADDRESS(ES) 10. SPONSOR/MONITOR’S ACRONYM(S) U.S. Army Medical Research and Materiel Command Fort Detrick, Maryland 21702-5012 11. SPONSOR/MONITOR’S
Gurina, T M; Vysekantsev, I P; Babinets, O M
2013-01-01
New implementation principle of freeze-thawing during cryopreservation of microorganisms, initiation of the process of crystal formation at cooling and thawing stage with the controlled rate of heating was experimentally substantiated. This allows increasing the cell viability, guaranteeing their equal number in each preparation, decreasing the contamination risk of the samples at thawing stage.
Zhou, Shiyue; Tello, Nadia; Harvey, Alex; Boyes, Barry; Orlando, Ron; Mechref, Yehia
2016-06-01
Glycans have numerous functions in various biological processes and participate in the progress of diseases. Reliable quantitative glycomic profiling techniques could contribute to the understanding of the biological functions of glycans, and lead to the discovery of potential glycan biomarkers for diseases. Although LC-MS is a powerful analytical tool for quantitative glycomics, the variation of ionization efficiency and MS intensity bias are influencing quantitation reliability. Internal standards can be utilized for glycomic quantitation by MS-based methods to reduce variability. In this study, we used stable isotope labeled IgG2b monoclonal antibody, iGlycoMab, as an internal standard to reduce potential for errors and to reduce variabililty due to sample digestion, derivatization, and fluctuation of nanoESI efficiency in the LC-MS analysis of permethylated N-glycans released from model glycoproteins, human blood serum, and breast cancer cell line. We observed an unanticipated degradation of isotope labeled glycans, tracked a source of such degradation, and optimized a sample preparation protocol to minimize degradation of the internal standard glycans. All results indicated the effectiveness of using iGlycoMab to minimize errors originating from sample handling and instruments. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Mathew, Elizabeth M; Rajiah, Kingston; Sharma, Krishana Kumar
2013-12-01
Printed education materials are often used to augment healthcare professional's verbal information to consumers so it serves as an important component of symptom management. They also enhance the teaching process and can be used by consumers as a home reference. This study was aimed to interpret consumers' perception on Consumer Medical Information Leaflets (CMILs) on obesity and lipid lowering drugs, on design and layout using the standard method such as Baker Able Leaflet Design (BALD). Convenience sampling was done. The study was conducted over a period of 3 years in community pharmacy settings in Tamil Nadu, India. The Consumer Medical Information Leaflets (CMILs) were randomly collected from different community pharmacies. Total of 19 CMILs which are commonly used by the consumers were collected and CMILs were assessed using BALD assessment tool Results: According to BALD assessment (46.28%) leaflets were rated as 'above standard' and (53.72) leaflets were rated as 'standard or poor' in layout and design since their scores were less than 25. This shows that this issue may be important from the patient's perspective, which may discourage patient from actually reading the CMILs. In India, generally CMILs are continued to be prepared in English and with higher proportion of consumers with English illiteracy. CMILs, which are prepared without taking consideration of reading level of consumers and proper layout and design, may not achieve the intended purpose. This is an important aspect that any company has to reckon while preparing leaflets and at least in some major local languages in which CMILs have to be prepared.
Pugsley, Haley R.; Swearingen, Kristian E.; Dovichi, Norman J.
2009-01-01
A number of algorithms have been developed to correct for migration time drift in capillary electrophoresis. Those algorithms require identification of common components in each run. However, not all components may be present or resolved in separations of complex samples, which can confound attempts for alignment. This paper reports the use of fluorescein thiocarbamyl derivatives of amino acids as internal standards for alignment of 3-(2-furoyl)quinoline-2-carboxaldehyde (FQ)-labeled proteins in capillary sieving electrophoresis. The fluorescein thiocarbamyl derivative of aspartic acid migrates before FQ-labeled proteins and the fluorescein thiocarbamyl derivative of arginine migrates after the FQ-labeled proteins. These compounds were used as internal standards to correct for variations in migration time over a two-week period in the separation of a cellular homogenate. The experimental conditions were deliberately manipulated by varying electric field and sample preparation conditions. Three components of the homogenate were used to evaluate the alignment efficiency. Before alignment, the average relative standard deviation in migration time for these components was 13.3%. After alignment, the average relative standard deviation in migration time for these components was reduced to 0.5%. PMID:19249052
EuroFlow standardization of flow cytometer instrument settings and immunophenotyping protocols
Kalina, T; Flores-Montero, J; van der Velden, V H J; Martin-Ayuso, M; Böttcher, S; Ritgen, M; Almeida, J; Lhermitte, L; Asnafi, V; Mendonça, A; de Tute, R; Cullen, M; Sedek, L; Vidriales, M B; Pérez, J J; te Marvelde, J G; Mejstrikova, E; Hrusak, O; Szczepański, T; van Dongen, J J M; Orfao, A
2012-01-01
The EU-supported EuroFlow Consortium aimed at innovation and standardization of immunophenotyping for diagnosis and classification of hematological malignancies by introducing 8-color flow cytometry with fully standardized laboratory procedures and antibody panels in order to achieve maximally comparable results among different laboratories. This required the selection of optimal combinations of compatible fluorochromes and the design and evaluation of adequate standard operating procedures (SOPs) for instrument setup, fluorescence compensation and sample preparation. Additionally, we developed software tools for the evaluation of individual antibody reagents and antibody panels. Each section describes what has been evaluated experimentally versus adopted based on existing data and experience. Multicentric evaluation demonstrated high levels of reproducibility based on strict implementation of the EuroFlow SOPs and antibody panels. Overall, the 6 years of extensive collaborative experiments and the analysis of hundreds of cell samples of patients and healthy controls in the EuroFlow centers have provided for the first time laboratory protocols and software tools for fully standardized 8-color flow cytometric immunophenotyping of normal and malignant leukocytes in bone marrow and blood; this has yielded highly comparable data sets, which can be integrated in a single database. PMID:22948490
Rhoderick, George C
2007-04-01
New US federal low-level automobile emission requirements, for example zero-level-emission vehicle (ZLEV), for hydrocarbons and other species, have resulted in the need by manufacturers for new certified reference materials. The new emission requirement for hydrocarbons requires the use, by automobile manufacturing testing facilities, of a 100 nmol mol(-1) propane in air gas standard. Emission-measurement instruments are required, by federal law, to be calibrated with National Institute of Standards and Technology (NIST) traceable reference materials. Because a NIST standard reference material (SRM) containing 100 nmol mol(-1) propane was not available, the US Environmental Protection Agency (EPA) and the Automobile Industry/Government Emissions Research Consortium (AIGER) requested that NIST develop such an SRM. A cylinder lot of 30 gas mixtures containing 100 nmol mol(-1) propane in air was prepared in 6-L aluminium gas cylinders by a specialty gas company and delivered to the Gas Metrology Group at NIST. Another mixture, contained in a 30-L aluminium cylinder and included in the lot, was used as a lot standard (LS). Using gas chromatography with flame-ionization detection all 30 samples were compared to the LS to obtain the average of six peak-area ratios to the LS for each sample with standard deviations of <0.31%. The average sample-to-LS ratio determinations resulted in a range of 0.9828 to 0.9888, a spread of 0.0060, which corresponds to a relative standard deviation of 0.15% of the average for all 30 samples. NIST developed its first set of five propane in air primary gravimetric standards covering a concentration range 91 to 103 nmol mol(-1) with relative uncertainties of 0.15%. This new suite of propane gravimetric standards was used to analyze and assign a concentration value to the SRM LS. On the basis of these data each SRM sample was individually certified, furnishing the desired relative expanded uncertainty of +/-0.5%. Because automobile companies use total hydrocarbons to make their measurements, it was also vital to assign a methane concentration to the SRM samples. Some of the SRM samples were analyzed and found to contain 1.2 nmol mol(-1) methane. Twenty-five of the samples were certified and released as SRM 2765.
Ramakumar, Adarsh; Subramanian, Uma; Prasanna, Pataje G S
2015-11-01
High-throughput individual diagnostic dose assessment is essential for medical management of radiation-exposed subjects after a mass casualty. Cytogenetic assays such as the Dicentric Chromosome Assay (DCA) are recognized as the gold standard by international regulatory authorities. DCA is a multi-step and multi-day bioassay. DCA, as described in the IAEA manual, can be used to assess dose up to 4-6 weeks post-exposure quite accurately but throughput is still a major issue and automation is very essential. The throughput is limited, both in terms of sample preparation as well as analysis of chromosome aberrations. Thus, there is a need to design and develop novel solutions that could utilize extensive laboratory automation for sample preparation, and bioinformatics approaches for chromosome-aberration analysis to overcome throughput issues. We have transitioned the bench-based cytogenetic DCA to a coherent process performing high-throughput automated biodosimetry for individual dose assessment ensuring quality control (QC) and quality assurance (QA) aspects in accordance with international harmonized protocols. A Laboratory Information Management System (LIMS) is designed, implemented and adapted to manage increased sample processing capacity, develop and maintain standard operating procedures (SOP) for robotic instruments, avoid data transcription errors during processing, and automate analysis of chromosome-aberrations using an image analysis platform. Our efforts described in this paper intend to bridge the current technological gaps and enhance the potential application of DCA for a dose-based stratification of subjects following a mass casualty. This paper describes one such potential integrated automated laboratory system and functional evolution of the classical DCA towards increasing critically needed throughput. Published by Elsevier B.V.
López-García, I; Viñas, P; Romero-Romero, R; Hernández-Córdoba, M
2007-08-06
Two procedures for the electrothermal atomic absorption spectrometric determination of molybdenum in milk and infant formulas using slurried samples are described. For powdered milk samples, 10% (m/v) slurries were prepared in a medium containing 25 and 75% (v/v) concentrated hydrogen peroxide and hydrofluoric acid, respectively, and introduced directly into the furnace. Palladium (200 microg mL(-1)) was used as the modifier and calibration was carried out using aqueous standards prepared in the same medium. The detection limit was 0.02 microg g(-1) for powdered milk samples suspended at 10% (m/v) (equivalent to 2 microg L(-1)). The relative standard deviation (R.S.D.) for five measurements was 1.9%, the characteristic mass being 25 pg. For liquid milk samples, a procedure was proposed based on preconcentration and removal of the matrix, using ionic exchange (Amberlite IRA 743) and elution of molybdenum with 5% (m/v) NaOH. In this case, a 30-fold improvement in the calibration slope was achieved, leading to a detection limit of 0.04 microg L(-1) for liquid samples diluted to 10%. The R.S.D. was 3.5%. Using a size-based separation procedure, it was found that molybdenum is present in its inorganic form or associated to low molecular weight substances in cow milk, while in breast milk it is associated to proteins. The reliability of the procedure was checked by comparing the results obtained with those found using a previous mineralization stage and by analyzing three certified reference materials, namely, BCR 063R (skim milk powder), NBS 1549 (non-fat milk powder) and NBS 8435 (whole milk powder).
Wagner, Rebecca; Wetzel, Stephanie J; Kern, John; Kingston, H M Skip
2012-02-01
The employment of chemical weapons by rogue states and/or terrorist organizations is an ongoing concern in the United States. The quantitative analysis of nerve agents must be rapid and reliable for use in the private and public sectors. Current methods describe a tedious and time-consuming derivatization for gas chromatography-mass spectrometry and liquid chromatography in tandem with mass spectrometry. Two solid-phase extraction (SPE) techniques for the analysis of glyphosate and methylphosphonic acid are described with the utilization of isotopically enriched analytes for quantitation via atmospheric pressure chemical ionization-quadrupole time-of-flight mass spectrometry (APCI-Q-TOF-MS) that does not require derivatization. Solid-phase extraction-isotope dilution mass spectrometry (SPE-IDMS) involves pre-equilibration of a naturally occurring sample with an isotopically enriched standard. The second extraction method, i-Spike, involves loading an isotopically enriched standard onto the SPE column before the naturally occurring sample. The sample and the spike are then co-eluted from the column enabling precise and accurate quantitation via IDMS. The SPE methods in conjunction with IDMS eliminate concerns of incomplete elution, matrix and sorbent effects, and MS drift. For accurate quantitation with IDMS, the isotopic contribution of all atoms in the target molecule must be statistically taken into account. This paper describes two newly developed sample preparation techniques for the analysis of nerve agent surrogates in drinking water as well as statistical probability analysis for proper molecular IDMS. The methods described in this paper demonstrate accurate molecular IDMS using APCI-Q-TOF-MS with limits of quantitation as low as 0.400 mg/kg for glyphosate and 0.031 mg/kg for methylphosphonic acid. Copyright © 2012 John Wiley & Sons, Ltd.
Pacifici, Roberta; Marchei, Emilia; Salvatore, Francesco; Guandalini, Luca; Busardò, Francesco Paolo; Pichini, Simona
2017-08-28
Cannabis has been used since ancient times to relieve neuropathic pain, to lower intraocular pressure, to increase appetite and finally to decrease nausea and vomiting. The combination of the psychoactive cannabis alkaloid Δ9-tetrahydrocannabinol (THC) with the non-psychotropic alkaloids cannabidiol (CBD) and cannabinol (CBN) demonstrated a higher activity than THC alone. The Italian National Institute of Health sought to establish conditions and indications on how to correctly use nationally produced cannabis to guarantee therapeutic continuity in individuals treated with medical cannabis. The evaluation of cannabinoids concentration and stability in standardized preparations of cannabis tea and cannabis oil was conducted using an easy and fast ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) assay. Extraction efficiency of oil was significantly higher than that of water with respect to the different cannabinoids. This was especially observed in the case of the pharmacologically active THC, CBD and their acidic precursors. Fifteen minutes boiling was sufficient to achieve the highest concentrations of cannabinoids in the cannabis tea solutions. At ambient temperature, a significant THC and CBD decrease to 50% or less of the initial concentration was observed over 3 and 7 days, respectively. When refrigerated at 4 °C, similar decreasing profiles were observed for the two compounds. The cannabinoids profile in cannabis oil obtained after pre-heating the flowering tops at 145 °C for 30 min in a static oven resulted in a complete decarboxylation of cannabinoid acids CBDA and THCA-A. Nevertheless, it was apparent that heat not only decarboxylated acidic compounds, but also significantly increased the final concentrations of cannabinoids in oil. The stability of cannabinoids in oil samples was higher than that in tea samples since the maximum decrease (72% of initial concentration) was observed in THC coming from unheated flowering tops at ambient temperature. In the case of the other cannabinoids, at ambient and refrigerated temperatures, 80%-85% of the initial concentrations were measured up to 14 days after oil preparation. As the first and most important aim of the different cannabis preparations is to guarantee therapeutic continuity in treated individuals, a strictly standardized preparation protocol is necessary to assure the availability of a homogeneous product of defined stability.
Characterization of oily sludge from a Tehran oil refinery.
Heidarzadeh, Nima; Gitipour, Saeid; Abdoli, Mohammad Ali
2010-10-01
In this study, oily sludge samples generated from a Tehran oil refinery (Pond I) were evaluated for their contamination levels and to propose an adequate remediation technique for the wastes. A simple, random, sampling method was used to collect the samples. The samples were analyzed to measure Total petroleum hydrocarbon (TPH), polyaromatic hydrocarbon (PAH) and heavy metal concentrations in the sludge. Statistical analysis showed that seven samples were adequate to assess the sludge with respect to TPH analyses. The mean concentration of TPHs in the samples was 265,600 mg kg⁻¹. A composite sample prepared from a mix of the seven samples was used to determine the sludge's additional characteristics. Composite sample analysis showed that there were no detectable amounts of PAHs in the sludge. In addition, mean concentrations of the selected heavy metals Ni, Pb, Cd and Zn were 2700, 850, 100, 6100 mg kg⁻¹, respectively. To assess the sludge contamination level, the results from the analysis above were compared with soil clean-up levels. Due to a lack of national standards for soil clean-up levels in Iran, sludge pollutant concentrations were compared with standards set in developed countries. According to these standards, the sludge was highly polluted with petroleum hydrocarbons. The results indicated that incineration, biological treatment and solidification/stabilization treatments would be the most appropriate methods for treatment of the sludges. In the case of solidification/stabilization, due to the high organic content of the sludge, it is recommended to use organophilic clays prior to treatment of the wastes.
Zarei, Ali Reza; Nedaei, Maryam; Ghorbanian, Sohrab Ali
2018-06-08
In this work, for the first time, ferrofluid of magnetic montmorillonite nanoclay and deep eutectic solvent was prepared and coupled with directly suspended droplet microextraction. Incorporation of ferrofluid in a miniaturized sample preparation technique resulted in achieving high extraction efficiency while developing a green analytical method. The prepared ferrofluid has strong sorbing properties and hydrophobic characteristics. In this method, a micro-droplet of ferrofluid was suspended into the vortex of a stirring aqueous solution and after completing the extraction process, was easily separated from the solution by a magnetic rod without any operational problems. The predominant experimental variables affecting the extraction efficiency of explosives were evaluated. Under optimal conditions, the limits of detection were in the range 0.22-0.91 μg L -1 . The enrichment factors were between 23 and 93 and the relative standard deviations were <10%. The relative recoveries were ranged from 88 to 104%. This method was successfully applied for the extraction and preconcentration of explosives in water and soil samples, followed their determination by high performance liquid chromatography with ultraviolet detection (HPLC-UV). Copyright © 2018 Elsevier B.V. All rights reserved.
Lin, Mei-Ling; Jiang, Shiuh-Jen
2013-12-01
Inductively coupled plasma mass spectrometry coupled with ultrasonic slurry sampling electrothermal vaporisation (USS-ETV-ICP-MS) has been applied to determine As, Cd, Hg and Pb in 0.5% m/v slurries of several herb samples. 1% m/v 8-Hydroxyquinoline was used as the modifier to enhance the ion signals. The influences of instrument operating conditions, slurry preparation and interferences on the ion signals were reported. This method has been applied to the determination of As, Cd, Hg and Pb in NIST SRM 1547 peach leaves and SRM 1573a tomato leaves reference materials and three herb samples purchased from the local market and ground to 150 μm. The analysis results of the standard reference materials agreed with the certified values which are at sub μg g(-1) levels. Precision between sample replicates was better than 4% for all the determinations. The method detection limits estimated from standard addition curves were about 0.3, 0.1, 0.1 and 0.2 ng g(-1) for As, Cd, Hg and Pb, respectively, in original herb samples. Copyright © 2013 Elsevier Ltd. All rights reserved.
CTBTO Contractor Laboratory Test Sample Production Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bob Hague; Tracy Houghton; Nick Mann
2013-08-01
In October 2012 scientists from both Idaho National Laboratory (INL) and the CTBTO contact laboratory at Seibersdorf, Austria designed a system and capability test to determine if the INL could produce and deliver a short lived radio xenon standard in time for the standard to be measured at the CTBTO contact laboratory at Seibersdorf, Austria. The test included sample standard transportation duration and potential country entrance delays at customs. On October 23, 2012 scientists at the Idaho National Laboratory (INL) prepared and shipped a Seibersdorf contract laboratory supplied cylinder. The canister contained 1.0 scc of gas that consisted of 70%more » xenon and 30% nitrogen by volume. The t0 was October 24, 2012, 1200 ZULU. The xenon content was 0.70 +/ 0.01 scc at 0 degrees C. The 133mXe content was 4200 +/ 155 dpm per scc of stable xenon on t0 (1 sigma uncertainty). The 133Xe content was 19000 +/ 800 dpm per scc of stable xenon on t0 (1 sigma uncertainty).« less
Effect of resin coating as a means of preventing marginal leakage beneath full cast crowns.
Kosaka, Satomi; Kajihara, Hirotada; Kurashige, Hisanori; Tanaka, Takuo
2005-03-01
The purpose of this study was to evaluate the effectiveness of resin coating as a means of preventing marginal leakage beneath full cast crowns which were emplaced using different cements. Standard full cast crown preparation was made on 64 extracted premolars. These samples were then divided into four groups, with half of each group coated with dentin coating material after preparation. Crowns were cemented onto the teeth using zinc cement, Fuji I, Vitremer, or C&B Metabond. The samples were thermal-cycled for 10,000 cycles. They were then immersed in erythrosine solution, sectioned, and observed under a microscope. Microleakage analyses were performed using a 0-4 point system. The data were statistically analyzed. There were significant differences between the coated specimens and the uncoated specimens using Fuji I and Vitremer. The results showed that a resin coating could decrease the amount of marginal leakage when applied with these two cements.
Stochastic Optical Reconstruction Microscopy (STORM).
Xu, Jianquan; Ma, Hongqiang; Liu, Yang
2017-07-05
Super-resolution (SR) fluorescence microscopy, a class of optical microscopy techniques at a spatial resolution below the diffraction limit, has revolutionized the way we study biology, as recognized by the Nobel Prize in Chemistry in 2014. Stochastic optical reconstruction microscopy (STORM), a widely used SR technique, is based on the principle of single molecule localization. STORM routinely achieves a spatial resolution of 20 to 30 nm, a ten-fold improvement compared to conventional optical microscopy. Among all SR techniques, STORM offers a high spatial resolution with simple optical instrumentation and standard organic fluorescent dyes, but it is also prone to image artifacts and degraded image resolution due to improper sample preparation or imaging conditions. It requires careful optimization of all three aspects-sample preparation, image acquisition, and image reconstruction-to ensure a high-quality STORM image, which will be extensively discussed in this unit. © 2017 by John Wiley & Sons, Inc. Copyright © 2017 John Wiley & Sons, Inc.
Oligosaccharide formation during commercial pear juice processing.
Willems, Jamie L; Low, Nicholas H
2016-08-01
The effect of enzyme treatment and processing on the oligosaccharide profile of commercial pear juice samples was examined by high performance anion exchange chromatography with pulsed amperometric detection and capillary gas chromatography with flame ionization detection. Industrial samples representing the major stages of processing produced with various commercial enzyme preparations were studied. Through the use of commercially available standards and laboratory scale enzymatic hydrolysis of pectin, starch and xyloglucan; galacturonic acid oligomers, glucose oligomers (e.g., maltose and cellotriose) and isoprimeverose were identified as being formed during pear juice production. It was found that the majority of polysaccharide hydrolysis and oligosaccharide formation occurred during enzymatic treatment at the pear mashing stage and that the remaining processing steps had minimal impact on the carbohydrate-based chromatographic profile of pear juice. Also, all commercial enzyme preparations and conditions (time and temperature) studied produced similar carbohydrate-based chromatographic profiles. Copyright © 2016 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Belsey, Natalie A.; Cant, David J. H.; Minelli, Caterina
We report the results of a VAMAS (Versailles Project on Advanced Materials and Standards) inter-laboratory study on the measurement of the shell thickness and chemistry of nanoparticle coatings. Peptide-coated gold particles were supplied to laboratories in two forms: a colloidal suspension in pure water and; particles dried onto a silicon wafer. Participants prepared and analyzed these samples using either X-ray photoelectron spectroscopy (XPS) or low energy ion scattering (LEIS). Careful data analysis revealed some significant sources of discrepancy, particularly for XPS. Degradation during transportation, storage or sample preparation resulted in a variability in thickness of 53 %. The calculation methodmore » chosen by XPS participants contributed a variability of 67 %. However, variability of 12 % was achieved for the samples deposited using a single method and by choosing photoelectron peaks that were not adversely affected by instrumental transmission effects. The study identified a need for more consistency in instrumental transmission functions and relative sensitivity factors, since this contributed a variability of 33 %. The results from the LEIS participants were more consistent, with variability of less than 10 % in thickness and this is mostly due to a common method of data analysis. The calculation was performed using a model developed for uniform, flat films and some participants employed a correction factor to account for the sample geometry, which appears warranted based upon a simulation of LEIS data from one of the participants and comparison to the XPS results.« less
Walsh, Stephen Joseph; Meador, Michael R.
1998-01-01
Fish community structure is characterized by the U.S. Geological Survey's National Water-Quality Assessment (NAWQA) Program as part of a perennial, multidisciplinary approach to evaluating the physical, chemical, and biological conditions of the Nation's water resources. The objective of quality assurance and quality control of fish taxonomic data that are collected as part of the NAWQA Program is to establish uniform guidelines and protocols for the identification, processing, and archiving of fish specimens to ensure that accurate and reliable data are collected. Study unit biologists, collaborating with regional biologists and fish taxonomic specialists, prepare a pre-sampling study plan that includes a preliminary faunal list and identification of an ichthyological curation center for receiving preserved fish specimens. Problematic taxonomic issues and protected taxa also are identified in the study plan, and collecting permits are obtained in advance of sampling activities. Taxonomic specialists are selected to identify fish specimens in the field and to assist in determining what fish specimens should be sacrificed, fixed, and preserved for laboratory identification, independent taxonomic verification, and long-term storage in reference or voucher collections. Quantitative and qualitative sampling of fishes follows standard methods previously established for the NAWQA Program. Common ichthyological techniques are used to process samples in the field and prepare fish specimens to be returned to the laboratory or sent to an institutional repository. Taxonomic identifications are reported by using a standardized list of scientific names that provides nomenclatural consistency and uniformity across study units.
30 CFR 827.13 - Coal preparation plants: Interim performance standards.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 3 2012-07-01 2012-07-01 false Coal preparation plants: Interim performance...-COAL PREPARATION PLANTS NOT LOCATED WITHIN THE PERMIT AREA OF A MINE § 827.13 Coal preparation plants: Interim performance standards. (a) Persons operating or who have operated coal preparation plants after...
30 CFR 827.13 - Coal preparation plants: Interim performance standards.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 3 2014-07-01 2014-07-01 false Coal preparation plants: Interim performance...-COAL PREPARATION PLANTS NOT LOCATED WITHIN THE PERMIT AREA OF A MINE § 827.13 Coal preparation plants: Interim performance standards. (a) Persons operating or who have operated coal preparation plants after...
30 CFR 827.13 - Coal preparation plants: Interim performance standards.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 3 2010-07-01 2010-07-01 false Coal preparation plants: Interim performance...-COAL PREPARATION PLANTS NOT LOCATED WITHIN THE PERMIT AREA OF A MINE § 827.13 Coal preparation plants: Interim performance standards. (a) Persons operating or who have operated coal preparation plants after...
30 CFR 827.12 - Coal preparation plants: Performance standards.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 3 2010-07-01 2010-07-01 false Coal preparation plants: Performance standards...-COAL PREPARATION PLANTS NOT LOCATED WITHIN THE PERMIT AREA OF A MINE § 827.12 Coal preparation plants..., modification, reclamation, and removal activities at coal preparation plants shall comply with the following...
30 CFR 827.13 - Coal preparation plants: Interim performance standards.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 3 2013-07-01 2013-07-01 false Coal preparation plants: Interim performance...-COAL PREPARATION PLANTS NOT LOCATED WITHIN THE PERMIT AREA OF A MINE § 827.13 Coal preparation plants: Interim performance standards. (a) Persons operating or who have operated coal preparation plants after...
30 CFR 827.12 - Coal preparation plants: Performance standards.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 3 2013-07-01 2013-07-01 false Coal preparation plants: Performance standards...-COAL PREPARATION PLANTS NOT LOCATED WITHIN THE PERMIT AREA OF A MINE § 827.12 Coal preparation plants..., modification, reclamation, and removal activities at coal preparation plants shall comply with the following...
30 CFR 827.13 - Coal preparation plants: Interim performance standards.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 3 2011-07-01 2011-07-01 false Coal preparation plants: Interim performance...-COAL PREPARATION PLANTS NOT LOCATED WITHIN THE PERMIT AREA OF A MINE § 827.13 Coal preparation plants: Interim performance standards. (a) Persons operating or who have operated coal preparation plants after...
30 CFR 827.12 - Coal preparation plants: Performance standards.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 3 2012-07-01 2012-07-01 false Coal preparation plants: Performance standards...-COAL PREPARATION PLANTS NOT LOCATED WITHIN THE PERMIT AREA OF A MINE § 827.12 Coal preparation plants..., modification, reclamation, and removal activities at coal preparation plants shall comply with the following...
30 CFR 827.12 - Coal preparation plants: Performance standards.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 3 2014-07-01 2014-07-01 false Coal preparation plants: Performance standards...-COAL PREPARATION PLANTS NOT LOCATED WITHIN THE PERMIT AREA OF A MINE § 827.12 Coal preparation plants..., modification, reclamation, and removal activities at coal preparation plants shall comply with the following...
30 CFR 827.12 - Coal preparation plants: Performance standards.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 3 2011-07-01 2011-07-01 false Coal preparation plants: Performance standards...-COAL PREPARATION PLANTS NOT LOCATED WITHIN THE PERMIT AREA OF A MINE § 827.12 Coal preparation plants..., modification, reclamation, and removal activities at coal preparation plants shall comply with the following...
Medvedovici, Andrei; Udrescu, Stefan; Albu, Florin; Tache, Florentin; David, Victor
2011-09-01
Liquid-liquid extraction of target compounds from biological matrices followed by the injection of a large volume from the organic layer into the chromatographic column operated under reversed-phase (RP) conditions would successfully combine the selectivity and the straightforward character of the procedure in order to enhance sensitivity, compared with the usual approach of involving solvent evaporation and residue re-dissolution. Large-volume injection of samples in diluents that are not miscible with the mobile phase was recently introduced in chromatographic practice. The risk of random errors produced during the manipulation of samples is also substantially reduced. A bioanalytical method designed for the bioequivalence of fenspiride containing pharmaceutical formulations was based on a sample preparation procedure involving extraction of the target analyte and the internal standard (trimetazidine) from alkalinized plasma samples in 1-octanol. A volume of 75 µl from the octanol layer was directly injected on a Zorbax SB C18 Rapid Resolution, 50 mm length × 4.6 mm internal diameter × 1.8 µm particle size column, with the RP separation being carried out under gradient elution conditions. Detection was made through positive ESI and MS/MS. Aspects related to method development and validation are discussed. The bioanalytical method was successfully applied to assess bioequivalence of a modified release pharmaceutical formulation containing 80 mg fenspiride hydrochloride during two different studies carried out as single-dose administration under fasting and fed conditions (four arms), and multiple doses administration, respectively. The quality attributes assigned to the bioanalytical method, as resulting from its application to the bioequivalence studies, are highlighted and fully demonstrate that sample preparation based on large-volume injection of immiscible diluents has an increased potential for application in bioanalysis.
Papp, Laszlo; Palcsu, Laszlo; Major, Zoltan; Rinyu, Laszlo; Tóth, Istvan
2012-01-01
This paper describes the procedure followed for noble gas measurements for litres, millilitres and microlitres of water samples in our laboratory, including sample preparation, mass spectrometric measurement procedure, and the complete calibrations. The preparation line extracts dissolved gases from water samples of volumes of 0.2 μ l to 3 l and it separates them as noble and other chemically active gases. Our compact system handles the following measurements: (i) determination of tritium concentration of environmental water samples by the (3)He ingrowth method; (ii) noble gas measurements from surface water and groundwater; and (iii) noble gas measurements from fluid inclusions of solid geological archives (e.g. speleothems). As a result, the tritium measurements have a detection limit of 0.012 TU, and the expectation value (between 1 and 20 TU) is within 0.2 % of the real concentrations with a standard deviation of 2.4 %. The reproducibility of noble gas measurements for water samples of 20-40 ml allows us to determine solubility temperatures by an uncertainty better than 0.5 °C. Moreover, noble gas measurements for tiny water amounts (in the microlitre range) show that the results of the performed calibration measurements for most noble gas isotopes occur with a deviation of less than 2 %. Theoretically, these precisions for noble gas concentrations obtained from measurements of waters samples of a few microlitres allow us to determine noble gas temperatures by an uncertainty of less than 1 °C. Here, we present the first noble gas measurements of tiny amounts of artificial water samples prepared under laboratory conditions.
Sharma, H S S; Reinard, N
2004-12-01
Flax fiber must be mechanically prepared to improve fineness and homogeneity of the sliver before chemical processing and wet-spinning. The changes in fiber characteristics are monitored by an airflow method, which is labor intensive and requires 90 minutes to process one sample. This investigation was carried out to develop robust visible and near-infrared calibrations that can be used as a rapid tool for quality assessment of input fibers and changes in fineness at the doubling (blending), first, second, third, and fourth drawing frames, and at the roving stage. The partial least squares (PLS) and principal component regression (PCR) methods were employed to generate models from different segments of the spectra (400-1100, 1100-1700, 1100-2498, 1700-2498, and 400-2498 nm) and a calibration set consisting of 462 samples obtained from the six processing stages. The calibrations were successfully validated with an independent set of 97 samples, and standard errors of prediction of 2.32 and 2.62 dtex were achieved with the best PLS (400-2498 nm) and PCR (1100-2498 nm) models, respectively. An optimized PLS model of the visible-near-infrared (vis-NIR) spectra explained 97% of the variation (R(2) = 0.97) in the sample set with a standard error of calibration (SEC) of 2.45 dtex and a standard error of cross-validation (SECV) of 2.51 dtex R(2) = 0.96). The mean error of the reference airflow method was 1.56 dtex, which is more accurate than the NIR calibration. The improvement in fiber fineness of the validation set obtained from the six production lines was predicted with an error range of -6.47 to +7.19 dtex for input fibers, -1.44 to +5.77 dtex for blended fibers at the doubling, and -4.72 to +3.59 dtex at the drawing frame stages. This level of precision is adequate for wet-spinners to monitor fiber fineness of input fibers and during the preparation of fibers. The advantage of visNIR spectroscopy is the potential capability of the technique to assess fineness and other important quality characteristics of a fiber sample simultaneously in less than 30 minutes; the disadvantages are the expensive instrumentation and the expertise required for operating the instrument compared to the reference method. These factors need to be considered by the industry before installing an off-line NIR system for predicting quality parameters of input materials and changes in fiber characteristics during mechanical processing.
A Multicenter Study To Evaluate the Performance of High-Throughput Sequencing for Virus Detection
Ng, Siemon H. S.; Vandeputte, Olivier; Aljanahi, Aisha; Deyati, Avisek; Cassart, Jean-Pol; Charlebois, Robert L.; Taliaferro, Lanyn P.
2017-01-01
ABSTRACT The capability of high-throughput sequencing (HTS) for detection of known and unknown viruses makes it a powerful tool for broad microbial investigations, such as evaluation of novel cell substrates that may be used for the development of new biological products. However, like any new assay, regulatory applications of HTS need method standardization. Therefore, our three laboratories initiated a study to evaluate performance of HTS for potential detection of viral adventitious agents by spiking model viruses in different cellular matrices to mimic putative materials for manufacturing of biologics. Four model viruses were selected based upon different physical and biochemical properties and commercial availability: human respiratory syncytial virus (RSV), Epstein-Barr virus (EBV), feline leukemia virus (FeLV), and human reovirus (REO). Additionally, porcine circovirus (PCV) was tested by one laboratory. Independent samples were prepared for HTS by spiking intact viruses or extracted viral nucleic acids, singly or mixed, into different HeLa cell matrices (resuspended whole cells, cell lysate, or total cellular RNA). Data were obtained using different sequencing platforms (Roche 454, Illumina HiSeq1500 or HiSeq2500). Bioinformatic analyses were performed independently by each laboratory using available tools, pipelines, and databases. The results showed that comparable virus detection was obtained in the three laboratories regardless of sample processing, library preparation, sequencing platform, and bioinformatic analysis: between 0.1 and 3 viral genome copies per cell were detected for all of the model viruses used. This study highlights the potential for using HTS for sensitive detection of adventitious viruses in complex biological samples containing cellular background. IMPORTANCE Recent high-throughput sequencing (HTS) investigations have resulted in unexpected discoveries of known and novel viruses in a variety of sample types, including research materials, clinical materials, and biological products. Therefore, HTS can be a powerful tool for supplementing current methods for demonstrating the absence of adventitious or unwanted viruses in biological products, particularly when using a new cell line. However, HTS is a complex technology with different platforms, which needs standardization for evaluation of biologics. This collaborative study was undertaken to investigate detection of different virus types using two different HTS platforms. The results of the independently performed studies demonstrated a similar sensitivity of virus detection, regardless of the different sample preparation and processing procedures and bioinformatic analyses done in the three laboratories. Comparable HTS detection of different virus types supports future development of reference virus materials for standardization and validation of different HTS platforms. PMID:28932815
Sampling protocol for post-landfall Deepwater Horizon oil release, Gulf of Mexico, 2010
Wilde, F.D.; Skrobialowski, S.C.; Hart, J.S.
2010-01-01
The protocols and procedures described in this report are designed to be used by U.S. Geological Survey (USGS) field teams for the collection of environmental data and samples in coastal areas affected by the 2010 Deepwater Horizon oil spill in the Gulf of Mexico. This sampling protocol focuses specifically on sampling for water, sediments, benthic invertebrates, and microorganisms (ambient bacterial populations) after shoreline arrival of petroleum-associated product on beach, barrier island, and wetland environments of the Gulf of Mexico coastal states. Deployment to sampling sites, site setup, and sample collection in these environments necessitates modifications to standard USGS sampling procedures in order to address the regulatory, logistical, and legal requirements associated with samples collected in oil-impacted coastal areas. This document, therefore, has been written as an addendum to the USGS National Field Manual for the Collection of Water-Quality Data (NFM) (http://pubs.water.usgs.gov/twri9A/), which provides the basis for training personnel in the use of standard USGS sampling protocols. The topics covered in this Gulf of Mexico oil-spill sampling protocol augment NFM protocols for field-deployment preparations, health and safety precautions, sampling and quality-assurance procedures, and decontamination requirements under potentially hazardous environmental conditions. Documentation procedures and maintenance of sample integrity by use of chain-of-custody procedures also are described in this protocol.
Kalina, Tomas; Flores-Montero, Juan; Lecrevisse, Quentin; Pedreira, Carlos E; van der Velden, Vincent H J; Novakova, Michaela; Mejstrikova, Ester; Hrusak, Ondrej; Böttcher, Sebastian; Karsch, Dennis; Sędek, Łukasz; Trinquand, Amelie; Boeckx, Nancy; Caetano, Joana; Asnafi, Vahid; Lucio, Paulo; Lima, Margarida; Helena Santos, Ana; Bonaccorso, Paola; van der Sluijs-Gelling, Alita J; Langerak, Anton W; Martin-Ayuso, Marta; Szczepański, Tomasz; van Dongen, Jacques J M; Orfao, Alberto
2015-02-01
Flow cytometric immunophenotyping has become essential for accurate diagnosis, classification, and disease monitoring in hemato-oncology. The EuroFlow Consortium has established a fully standardized "all-in-one" pipeline consisting of standardized instrument settings, reagent panels, and sample preparation protocols and software for data analysis and disease classification. For its reproducible implementation, parallel development of a quality assurance (QA) program was required. Here, we report on the results of four consecutive annual rounds of the novel external QA EuroFlow program. The novel QA scheme aimed at monitoring the whole flow cytometric analysis process (cytometer setting, sample preparation, acquisition and analysis) by reading the median fluorescence intensities (MedFI) of defined lymphocytes' subsets. Each QA participant applied the predefined reagents' panel on blood cells of local healthy donors. A uniform gating strategy was applied to define lymphocyte subsets and to read MedFI values per marker. The MedFI values were compared with reference data and deviations from reference values were quantified using performance score metrics. In four annual QA rounds, we analyzed 123 blood samples from local healthy donors on 14 different instruments in 11 laboratories from nine European countries. The immunophenotype of defined cellular subsets appeared sufficiently standardized to permit unified (software) data analysis. The coefficient of variation of MedFI for 7 of 11 markers performed repeatedly below 30%, average MedFI in each QA round ranged from 86 to 125% from overall median. Calculation of performance scores was instrumental to pinpoint standardization failures and their causes. Overall, the new EuroFlow QA system for the first time allowed to quantify the technical variation that is introduced in the measurement of fluorescence intensities in a multicentric setting over an extended period of time. EuroFlow QA is a proficiency test specific for laboratories that use standardized EuroFlow protocols. It may be used to complement, but not replace, established proficiency tests. © 2014 International Society for Advancement of Cytometry. © 2014 International Society for Advancement of Cytometry.
Ferguson, Morag; Heath, Alan
2004-12-01
Yellow fever vaccines are routinely assayed by plaque assay. However, the results of these assays are then converted into mouse LD(50) using correlations/conversion factors which, in many cases, were established many years ago. The minimum required potency in WHO Recommendations is 10(3) LD(50)/dose. Thirteen participants from 8 countries participated in a collaborative study whose aim was to assess the suitability of two candidate preparations to serve as an International Standard for yellow fever vaccine. In addition, the study investigated the relationship between the mouse LD(50) test and plaque forming units with a view to updating the WHO recommendations. Plaque assays were more reproducible than mouse assays, as expected. Differences in sensitivities of plaque assays were observed between laboratories but these differences appear to be consistent within a laboratory for all samples and the expression of potency relative to the candidate standard vaccine improved the reproducibility of assays between laboratories. However, the use of potencies had little effect on the between laboratory variability in mouse LD(50) assays. There appears to be a consistent relationship between overall mean LD(50) and plaques titre for all study preparations other than sample E. The slope of the correlation curve is >1 and it would appear that 10(3) LD(50) is approximately equivalent to 10(4) plaque forming units (PFU), based on the overall means of all laboratory results. The First International Standard for yellow fever vaccine, NIBSC Code 99/616, has been established as the First International Standard for yellow fever vaccine by the Expert Committee of Biological Standards of the World Health Organisation. The International Standard has been arbitrarily assigned a potency of 10(4.5) International Units (IU) per ampoule. Manufacturers and National Control Laboratories are including the First International Standard for yellow fever vaccine in routine assays so that the minimum potency in IU of vaccines released for use and which meet the current minimum potency of 10(3) LD(50) in mouse assays, can be determined. These data will be analysed before a review of the WHO requirements, including the minimum potency per dose, is undertaken.
Molecular epidemiology biomarkers-Sample collection and processing considerations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Holland, Nina T.; Pfleger, Laura; Berger, Eileen
2005-08-07
Biomarker studies require processing and storage of numerous biological samples with the goals of obtaining a large amount of information and minimizing future research costs. An efficient study design includes provisions for processing of the original samples, such as cryopreservation, DNA isolation, and preparation of specimens for exposure assessment. Use of standard, two-dimensional and nanobarcodes and customized electronic databases assure efficient management of large sample collections and tracking results of data analyses. Standard operating procedures and quality control plans help to protect sample quality and to assure validity of the biomarker data. Specific state, federal and international regulations are inmore » place regarding research with human samples, governing areas including custody, safety of handling, and transport of human samples. Appropriate informed consent must be obtained from the study subjects prior to sample collection and confidentiality of results maintained. Finally, examples of three biorepositories of different scale (European Cancer Study, National Cancer Institute and School of Public Health Biorepository, University of California, Berkeley) are used to illustrate challenges faced by investigators and the ways to overcome them. New software and biorepository technologies are being developed by many companies that will help to bring biological banking to a new level required by molecular epidemiology of the 21st century.« less
Lim, Young-Il; Han, Janghee; Woo, Young-Ah; Kim, Jaejin; Kang, Myung Joo
2018-07-05
The purpose of this study was to determine the atorvastatin (ATV) content in process pharmaceutical powder sample using Raman spectroscopy. To establish the analysis method, the influence of the type of Raman measurements (back-scattering or transmission mode), preparation of calibration sample (simple admixing or granulation), sample pre-treatment (pelletization), and spectral pretreatment on the Raman spectra was investigated. The characteristic peak of the active compound was more distinctively detected in transmission Raman mode with a laser spot size of 4mm than in the back-scattering method. Preparation of calibration samples by wet granulation, identical to the actual manufacturing process, provided unchanged spectral patterns for the in process sample, with no changes and/or shifts in the spectrum. Pelletization before Raman analysis remarkably improved spectral reproducibility by decreasing the difference in density between the samples. Probabilistic quotient normalization led to accurate and consistent quantification of the ATV content in the calibration samples (standard error of cross validation: 1.21%). Moreover, the drug content in the granules obtained from five commercial batches were reliably quantified, with no statistical difference (p=0.09) with that obtained by HPLC assay. From these findings, we suggest that transmission Raman analysis may be a fast and non-invasive method for the quantification of ATV in actual manufacturing processes. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Liu, Xiaolan; He, Man; Chen, Beibei; Hu, Bin
2014-11-01
A novel method based on on-line polymer monolithic capillary microextraction (CME)-inductively coupled plasma mass spectrometry (ICP-MS) was developed for the determination of trace Au and Pd in biological samples. For this purpose, poly(glycidyl methacrylate-ethylene dimethacrylate) monolith was prepared and functionalized with mercapto groups. The prepared monolith exhibited good selectivity to Au and Pd, and good resistance to strong acid with a long life span. Factors affecting the extraction efficiency of CME, such as sample acidity, sample flow rate, eluent conditions and coexisting ion interference were investigated in detail. Under the optimal conditions, the limits of detection (LODs, 3σ) were 5.9 ng L- 1 for Au and 8.3 ng L- 1 for Pd, and the relative standard deviations (RSDs, c = 50 ng L-1, n = 7) were 6.5% for Au and 1.1% for Pd, respectively. The developed method was successfully applied to the determination of Au and Pd in human urine and serum samples with the recovery in the range of 84-118% for spiked samples. The developed on-line polymer monolithic CME-ICP-MS method has the advantages of rapidity, simplicity, low sample/reagent consumption, high sensitivity and is suitable for the determination of trace Au and Pd in biological samples with limited amount available and complex matrix.
NASA Astrophysics Data System (ADS)
Lim, Young-Il; Han, Janghee; Woo, Young-Ah; Kim, Jaejin; Kang, Myung Joo
2018-07-01
The purpose of this study was to determine the atorvastatin (ATV) content in process pharmaceutical powder sample using Raman spectroscopy. To establish the analysis method, the influence of the type of Raman measurements (back-scattering or transmission mode), preparation of calibration sample (simple admixing or granulation), sample pre-treatment (pelletization), and spectral pretreatment on the Raman spectra was investigated. The characteristic peak of the active compound was more distinctively detected in transmission Raman mode with a laser spot size of 4 mm than in the back-scattering method. Preparation of calibration samples by wet granulation, identical to the actual manufacturing process, provided unchanged spectral patterns for the in process sample, with no changes and/or shifts in the spectrum. Pelletization before Raman analysis remarkably improved spectral reproducibility by decreasing the difference in density between the samples. Probabilistic quotient normalization led to accurate and consistent quantification of the ATV content in the calibration samples (standard error of cross validation: 1.21%). Moreover, the drug content in the granules obtained from five commercial batches were reliably quantified, with no statistical difference (p = 0.09) with that obtained by HPLC assay. From these findings, we suggest that transmission Raman analysis may be a fast and non-invasive method for the quantification of ATV in actual manufacturing processes.
Subattomole sensitivity in biological accelerator mass spectrometry.
Salehpour, Mehran; Possnert, Göran; Bryhni, Helge
2008-05-15
The Uppsala University 5 MV Pelletron tandem accelerator has been used to study (14)C-labeled biological samples utilizing accelerator mass spectrometry (AMS) technology. We have adapted a sample preparation method for small biological samples down to a few tens of micrograms of carbon, involving among others, miniaturizing of the graphitization reactor. Standard AMS requires about 1 mg of carbon with a limit of quantitation of about 10 amol. Results are presented for a range of small sample sizes with concentrations down to below 1 pM of a pharmaceutical substance in human blood. It is shown that (14)C-labeled molecular markers can be routinely measured from the femtomole range down to a few hundred zeptomole (10 (-21) mol), without the use of any additional separation methods.
Revised Toxicological Assessment of ISS Air Quality: May 2012 - August 2012
NASA Technical Reports Server (NTRS)
Meyers, Valerie
2012-01-01
A summary of the analytical results from 12 grab sample containers (GSCs) collected on ISS and returned aboard 30S is shown in Table 1. The average recoveries of the 3 surrogate standards from the GSCs were as follows: 12C-acetone, 115 +/-- 11%; fluorobenzene, 108 +/- 8%; and chlorobenzene, 102 +/- 16%. Shaded rows indicate data that re limited due to low sample pressures. For completeness, previously reported data from the US Lab collected in May 2012 are included here as well. The revised report provides results from one returned sample that was unlabeled and originally assumed to be unused. The sample was prepared and analyzed for the purpose of measuring the surrogate compounds. It was later determined, based on serial number, that this was the HTB3 first ingress sample.
NASA Astrophysics Data System (ADS)
Shen, Chuan-Chou; Lin, Huei-Ting; Chu, Mei-Fei; Yu, Ein-Fen; Wang, Xianfeng; Dorale, Jeffrey A.
2006-09-01
A new analytical technique using inductively coupled plasma-quadrupole mass spectrometry (ICP-QMS) has been developed that produces permil-level precision in the measurement of uranium concentration ([U]) and isotopic composition (δ234U) in natural materials. A 233U-236U double spike method was used to correct for mass fractionation during analysis. To correct for ratio drifting, samples were bracketed by uranium standard measurements. A sensitivity of 6-7 × 108 cps/ppm was generated with a sample solution uptake rate of 30 μL/min. With a measurement time of 15-20 min, standards of 30-ng uranium produced a within-run precision better than 3‰ (±2 R.S.D.) for δ234U and better than 2‰ for [U]. Replicate measurements made on standards show that a between-run reproducibility of 3.5‰ for δ234U and 2‰ for [U] can be achieved. ICP-QMS data of δ234U and [U] in seawater, coral, and speleothem materials are consistent with the data measured by other ICP-MS and TIMS techniques. Advantages of the ICP-QMS method include low cost, easy maintenance, simple instrumental operation, and few sample preparation steps. Sample size requirements are small, such as 10-14 mg of coral material. The results demonstrate that this technique can be applied to natural samples with various matrices.
Coran, Silvia A; Giannellini, Valerio; Bambagiotti-Alberti, Massimo
2004-08-06
A HPTLC-densitometric method, based on an external standard approach, was developed in order to obtain a novel procedure for routine analysis of secoisolariciresinol diglucoside (SDG) in flaxseed with a minimum of sample pre-treatment. Optimization of TLC conditions for the densitometric scanning was reached by eluting HPTLC silica gel plates in a horizontal developing chamber. Quantitation of SDG was performed in single beam reflectance mode by using a computer-controlled densitometric scanner and applying a five-point calibration in the 1.00-10.00 microg/spot range. As no sample preparation was required, the proposed HPTLC-densitometric procedure demonstrated to be reliable, yet using an external standard approach. The proposed method is precise, reproducible and accurate and can be employed profitably in place of HPLC for the determination of SDG in complex matrices.
Hiebl, Bernhard; Lützow, Karola; Lange, Maik; Jung, Friedrich; Seifert, Barbara; Klein, Frank; Weigel, Thomas; Kratz, Karl; Lendlein, Andreas
2010-07-01
Most polymers used in clinical applications today are materials that have been developed originally for application areas other than biomedicine. Testing the cell- and tissue-compatibility of novel materials in vitro and in vivo is of key importance for the approval of medical devices and is regulated according to the Council Directive 93/42/EEC of the European communities concerning medical devices. In the standardized testing methods the testing sample is placed in commercially available cell culture plates, which are often made from polystyrene. Thus not only the testing sample itself influences cell behavior but also the culture vessel material. In order to exclude this influence, a new system for cell testing will be presented allowing a more precise and systematic investigation by preparing tailored inserts which are made of the testing material. Inserts prepared from polystyrene, polycarbonate and poly(ether imide) were tested for their cytotoxity and cell adherence. Furthermore a proof of principle concerning the preparation of inserts with a membrane-like surface structure and its surface modification was established. Physicochemical investigations revealed a similar morphology and showed to be very similar to the findings to analogous preparations and modifications of flat-sheet membranes. Copyright (c) 2010 Elsevier B.V. All rights reserved.
Peng, Jun; Chen, Yi-Ting; Chen, Chien-Lun; Li, Liang
2014-07-01
Large-scale metabolomics study requires a quantitative method to generate metabolome data over an extended period with high technical reproducibility. We report a universal metabolome-standard (UMS) method, in conjunction with chemical isotope labeling liquid chromatography-mass spectrometry (LC-MS), to provide long-term analytical reproducibility and facilitate metabolome comparison among different data sets. In this method, UMS of a specific type of sample labeled by an isotope reagent is prepared a priori. The UMS is spiked into any individual samples labeled by another form of the isotope reagent in a metabolomics study. The resultant mixture is analyzed by LC-MS to provide relative quantification of the individual sample metabolome to UMS. UMS is independent of a study undertaking as well as the time of analysis and useful for profiling the same type of samples in multiple studies. In this work, the UMS method was developed and applied for a urine metabolomics study of bladder cancer. UMS of human urine was prepared by (13)C2-dansyl labeling of a pooled sample from 20 healthy individuals. This method was first used to profile the discovery samples to generate a list of putative biomarkers potentially useful for bladder cancer detection and then used to analyze the verification samples about one year later. Within the discovery sample set, three-month technical reproducibility was examined using a quality control sample and found a mean CV of 13.9% and median CV of 9.4% for all the quantified metabolites. Statistical analysis of the urine metabolome data showed a clear separation between the bladder cancer group and the control group from the discovery samples, which was confirmed by the verification samples. Receiver operating characteristic (ROC) test showed that the area under the curve (AUC) was 0.956 in the discovery data set and 0.935 in the verification data set. These results demonstrated the utility of the UMS method for long-term metabolomics and discovering potential metabolite biomarkers for diagnosis of bladder cancer.
Compilation of nuclear standards, 9th edition, 1972. Part I. United States activities. Final issue
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
Activities in nuclear standards preparation are presented in tables. Technical, industrial, and environmental organizations preparing standards are listed alphabetically and their activities are given. Approved standards, unapproved drafts, and tentative standards are listed. Standards are indexed by organization and permuted title. (FS)
Berenbaum, Howard; Okazaki, Sumie
2012-01-01
The current study examined perceptions of living up to parental expectations and personal standards as possible mediators of the relationship between ethnicity and worry in a sample of 836 Asian American and 856 White American college students. Asian Americans reported higher frequency of academic- and family-related worry, but they did not report higher levels of global tendency to worry. Perceptions of living up to parental expectations of current academic performance and personal standards for preparation for a future career partially explained ethnic differences in frequency of academic worry. Personal standards and perceptions of living up to parental expectations for respect for the family partially explained ethnic differences in frequency of family worry. The findings highlight the importance of targeting domain-specific personal standards and perceived parental expectations to reduce worry among Asian Americans. PMID:22416875
Stavileci, Miranda; Hoxha, Veton; Görduysus, Ömer; Tatar, Ilkan; Laperre, Kjell; Hostens, Jeroen; Küçükkaya, Selen; Muhaxheri, Edmond
2015-01-01
Background Complete mechanical preparation of the root canal system is rarely achieved. Therefore, the purpose of this study was to evaluate and compare the root canal shaping efficacy of ProTaper rotary files and standard stainless steel K-files using micro-computed tomography. Material/Methods Sixty extracted upper second premolars were selected and divided into 2 groups of 30 teeth each. Before preparation, all samples were scanned by micro-computed tomography. Thirty teeth were prepared with the ProTaper system and the other 30 with stainless steel files. After preparation, the untouched surface and root canal straightening were evaluated with micro-computed tomography. The percentage of untouched root canal surface was calculated in the coronal, middle, and apical parts of the canal. We also calculated straightening of the canal after root canal preparation. Results from the 2 groups were statistically compared using the Minitab statistical package. Results ProTaper rotary files left less untouched root canal surface compared with manual preparation in coronal, middle, and apical sector (p<0.001). Similarly, there was a statistically significant difference in root canal straightening after preparation between the techniques (p<0.001). Conclusions Neither manual nor rotary techniques completely prepared the root canal, and both techniques caused slight straightening of the root canal. PMID:26092929
Stavileci, Miranda; Hoxha, Veton; Görduysus, Ömer; Tatar, Ilkan; Laperre, Kjell; Hostens, Jeroen; Küçükkaya, Selen; Muhaxheri, Edmond
2015-06-20
Complete mechanical preparation of the root canal system is rarely achieved. Therefore, the purpose of this study was to evaluate and compare the root canal shaping efficacy of ProTaper rotary files and standard stainless steel K-files using micro-computed tomography. Sixty extracted upper second premolars were selected and divided into 2 groups of 30 teeth each. Before preparation, all samples were scanned by micro-computed tomography. Thirty teeth were prepared with the ProTaper system and the other 30 with stainless steel files. After preparation, the untouched surface and root canal straightening were evaluated with micro-computed tomography. The percentage of untouched root canal surface was calculated in the coronal, middle, and apical parts of the canal. We also calculated straightening of the canal after root canal preparation. Results from the 2 groups were statistically compared using the Minitab statistical package. ProTaper rotary files left less untouched root canal surface compared with manual preparation in coronal, middle, and apical sector (p<0.001). Similarly, there was a statistically significant difference in root canal straightening after preparation between the techniques (p<0.001). Neither manual nor rotary techniques completely prepared the root canal, and both techniques caused slight straightening of the root canal.
Hoffman, Gerald L.
1996-01-01
A method for the chemical preparation of tissue samples that are subsequently analyzed for 22 trace metals is described. The tissue-preparation procedure was tested with three National Institute of Standards and Technology biological standard reference materials and two National Water Quality Laboratory homogenized biological materials. A low-temperature (85 degrees Celsius) nitric acid digestion followed by the careful addition of hydrogen peroxide (30-percent solution) is used to decompose the biological material. The solutions are evaporated to incipient dryness, reconstituted with 5 percent nitric acid, and filtered. After filtration the solutions were diluted to a known volume and analyzed by inductively coupled plasma-mass spectrometry (ICP-MS), inductively coupled plasma-atomic emission spectrometry (ICP-AES), and cold vapor-atomic absorption spectrophotometry (CV-AAS). Many of the metals were determined by both ICP-MS and ICP-AES. This report does not provide a detailed description of the instrumental procedures and conditions used with the three types of instrumentation for the quantitation of trace metals determined in this study. Statistical data regarding recovery, accuracy, and precision for individual trace metals determined in the biological material tested are summarized.
NASA Astrophysics Data System (ADS)
Nixon, David E.; Neubauer, Kenneth R.; Eckdahl, Steven J.; Butz, John A.; Burritt, Mary F.
2002-05-01
A Dynamic Reaction Cell™ inductively coupled argon plasma mass spectrometer (DRC-ICP-MS) was evaluated for the determination of chromium and vanadium in serum and urine. Reaction cell conditions were evaluated for the elimination of ArC + and ClOH + interferences on chromium at mass 52 and OCl + on vanadium at mass 51. A diluent containing only 1% nitric acid and internal standards (Y and Ga) was used to prepare serum and urine for analysis. Instrument response calibration was achieved by using aqueous acidic standards spiked into pooled sera or urine matrices. The slopes of the calibration curves prepared in urine and serum matrices were nearly identical. On average, chromium detection limits are 2.5 times lower using the DRC than Zeeman graphite furnace atomic absorption spectrometry (ZGFAAS). Vanadium detection limits are approximately 50 times lower. Average detection limits achieved with DRC-ICP-MS are 0.075 μg Cr/l and 0.028 μg V/l. Average results for the analysis of National Institute of Standards and Technology Standard Reference Material (NIST SRM) 1598 Bovine Serum (attained over 22 days) are: 0.14 μg Cr/l and 0.068 μg V/l. The reference concentrations for vanadium and chromium in NIST SRM 1598 are (0.06) μg V/l and 0.14±0.08 μg Cr/l, respectively. Results for chromium and vanadium determinations on ICP-MS survey samples from the Toxocologie du Quebec are equivalent to those reported by high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for the same survey samples.
Meyer, B; Morin, V N; Rödger, H-J; Holah, J; Bird, C
2010-04-01
The results from European standard disinfectant tests are used as one basis to approve the use of disinfectants in Europe. The design of these laboratory-based tests should thus simulate as closely as possible the practical conditions and challenges that the disinfectants would encounter in use. No evidence is available that the organic and microbial loading in these tests simulates actual levels in the food service sector. Total organic carbon (TOC) and total viable count (TVC) were determined on 17 visibly clean and 45 visibly dirty surfaces in two restaurants and the food preparation surfaces of a large retail store. These values were compared to reference values recovered from surfaces soiled with the organic and microbial loading, following the standard conditions of the European Surface Test for bactericidal efficacy, EN 13697. The TOC reference values for clean and dirty conditions were higher than the data from practice, but cannot be regarded as statistical outliers. This was considered as a conservative assessment; however, as additional nine TOC samples from visibly dirty surfaces were discarded from the analysis, as their loading made them impossible to process. Similarly, the recovery of test organisms from surfaces contaminated according to EN 13697 was higher than the TVC from visibly dirty surfaces in practice; though they could not be regarded as statistical outliers of the whole data field. No correlation was found between TVC and TOC in the sampled data, which re-emphasizes the potential presence of micro-organisms on visibly clean surfaces and thus the need for the same degree of disinfection as visibly dirty surfaces. The organic soil and the microbial burden used in EN disinfectant standards represent a realistic worst-case scenario for disinfectants used in the food service and food-processing areas.
Quantification and characterization of Si in Pinus Insignis Dougl by TXRF
NASA Astrophysics Data System (ADS)
Navarro, Henry; Bennun, Leonardo; Marcó, Lué M.
2015-03-01
A simple quantification of silicon is described, in woods such as Pinus Insigne Dougl obtained from the 8th region of Bío-Bío, 37°15″ South-73°19″ West, Chile. The samples were prepared through fractional calcination, and the ashes were directly analyzed by total reflection X-ray fluorescence (TXRF) technique. The analysis of 16 samples that were calcined is presented. The samples were weighed on plastic reflectors in a microbalance with sensitivity of 0.1 µg. Later, the samples were irradiated in a TXRF PICOFOX spectrometer, for 350 and 700 s. To each sample, cobalt was added as an internal standard. Concentrations of silicon over the 1 % in each sample and the self-absorption effect on the quantification were observed, in masses higher than 100 μg.
Lehmann, Roland; Schmidt, André; Pastuschek, Jana; Müller, Mario M; Fritzsche, Andreas; Dieterle, Stefan; Greb, Robert R; Markert, Udo R; Slevogt, Hortense
2018-06-25
The proteomic analysis of complex body fluids by liquid chromatography tandem mass spectrometry (LC-MS/MS) analysis requires the selection of suitable sample preparation techniques and optimal parameter settings in data analysis software packages to obtain reliable results. Proteomic analysis of follicular fluid, as a representative of a complex body fluid similar to serum or plasma, is difficult as it contains a vast amount of high abundant proteins and a variety of proteins with different concentrations. However, the accessibility of this complex body fluid for LC-MS/MS analysis is an opportunity to gain insights into the status, the composition of fertility-relevant proteins including immunological factors or for the discovery of new diagnostic and prognostic markers for, for example, the treatment of infertility. In this study, we compared different sample preparation methods (FASP, eFASP and in-solution digestion) and three different data analysis software packages (Proteome Discoverer with SEQUEST, Mascot and MaxQuant with Andromeda) combined with semi- and full-tryptic databank search options to obtain a maximum coverage of the follicular fluid proteome. We found that the most comprehensive proteome coverage is achieved by the eFASP sample preparation method using SDS in the initial denaturing step and the SEQUEST-based semi-tryptic data analysis. In conclusion, we have developed a fractionation-free methodical workflow for in depth LC-MS/MS-based analysis for the standardized investigation of human follicle fluid as an important representative of a complex body fluid. Taken together, we were able to identify a total of 1392 proteins in follicular fluid. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Simple and accurate quantification of BTEX in ambient air by SPME and GC-MS.
Baimatova, Nassiba; Kenessov, Bulat; Koziel, Jacek A; Carlsen, Lars; Bektassov, Marat; Demyanenko, Olga P
2016-07-01
Benzene, toluene, ethylbenzene and xylenes (BTEX) comprise one of the most ubiquitous and hazardous groups of ambient air pollutants of concern. Application of standard analytical methods for quantification of BTEX is limited by the complexity of sampling and sample preparation equipment, and budget requirements. Methods based on SPME represent simpler alternative, but still require complex calibration procedures. The objective of this research was to develop a simpler, low-budget, and accurate method for quantification of BTEX in ambient air based on SPME and GC-MS. Standard 20-mL headspace vials were used for field air sampling and calibration. To avoid challenges with obtaining and working with 'zero' air, slope factors of external standard calibration were determined using standard addition and inherently polluted lab air. For polydimethylsiloxane (PDMS) fiber, differences between the slope factors of calibration plots obtained using lab and outdoor air were below 14%. PDMS fiber provided higher precision during calibration while the use of Carboxen/PDMS fiber resulted in lower detection limits for benzene and toluene. To provide sufficient accuracy, the use of 20mL vials requires triplicate sampling and analysis. The method was successfully applied for analysis of 108 ambient air samples from Almaty, Kazakhstan. Average concentrations of benzene, toluene, ethylbenzene and o-xylene were 53, 57, 11 and 14µgm(-3), respectively. The developed method can be modified for further quantification of a wider range of volatile organic compounds in air. In addition, the new method is amenable to automation. Copyright © 2016 Elsevier B.V. All rights reserved.
Goh, Sherry Meow Peng; Swaminathan, Muthukaruppan; Lai, Julian U-Ming; Anwar, Azlinda; Chan, Soh Ha; Cheong, Ian
2017-01-01
High Epstein Barr Virus (EBV) titers detected by the indirect Immunofluorescence Assay (IFA) are a reliable predictor of Nasopharyngeal Carcinoma (NPC). Despite being the gold standard for serological detection of NPC, the IFA is limited by scaling bottlenecks. Specifically, 5 serial dilutions of each patient sample must be prepared and visually matched by an evaluator to one of 5 discrete titers. Here, we describe a simple method for inferring continuous EBV titers from IFA images acquired from NPC-positive patient sera using only a single sample dilution. In the first part of our study, 2 blinded evaluators used a set of reference titer standards to perform independent re-evaluations of historical samples with known titers. Besides exhibiting high inter-evaluator agreement, both evaluators were also in high concordance with historical titers, thus validating the accuracy of the reference titer standards. In the second part of the study, the reference titer standards were IFA-processed and assigned an 'EBV Score' using image analysis. A log-linear relationship between titers and EBV Score was observed. This relationship was preserved even when images were acquired and analyzed 3days post-IFA. We conclude that image analysis of IFA-processed samples can be used to infer a continuous EBV titer with just a single dilution of NPC-positive patient sera. This work opens new possibilities for improving the accuracy and scalability of IFA in the context of clinical screening. Copyright © 2016. Published by Elsevier B.V.
Writing Material Safely Data Sheets Using the ANSI Standard.
ERIC Educational Resources Information Center
Croft, Suzanne D.
1996-01-01
Presents a history of the ANSI (American National Standards Institute) standard for preparation of Material Safety Data Sheets (MSDS), and provides a section-by-section guide to preparing MSDSs that comply with the standard. (SR)
Comparison of human chorionic somatomammotropin (HCS) standards for radioimmunoassay
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cocola, F.; Genazzani, A.R.; Neri, P.
1973-01-01
A comparison was made between four commercially available HCS standards for radioimmunoassay, an interim standard from the Division of Biological Standards of the Medical Research Council. and a new preparation from our laboratories. Many differences are found between the various HCS preparations tested, and this may be one reason for the discrepancies found in absolute HCS plasma levels reported by different authors. The new Sclavo preparation seems to be the best, and its use is proposed as a new standard for radioimmunoassay. (auth)
Zhang, Zhuomin; Ma, Yunjian; Wang, Qingtang; Chen, An; Pan, Zhuoyan; Li, Gongke
2013-05-17
A novel alumina nanowire (ANW) solid-phase microextraction (SPME) fiber coating was prepared by a simple and rapid anodization-chemical etching method for ultra-selective determination of volatile esters and alcohols from complicated food samples. Preparation conditions for ANW SPME fiber coating including corrosion solution concentration and corrosion time were optimized in detail for better surface morphology and higher surface area based on scanning electron microscope (SEM). Under the optimum conditions, homogeneous alumina nanowire structure of ANW SPME fiber coating was achieved with the average thickness of 20 μm around. Compared with most of commercial SPME fiber coatings, ANW SPME fiber coatings achieved the higher extraction capacity and special selectivity for volatile esters and alcohols. Finally, an efficient gas sampling technique based on ANW SPME fiber coating as the core was established and successfully applied for the ultra-selective determination of trace volatile esters and alcohols from complicated banana and fermented glutinous rice samples coupled with gas chromatography/mass spectrometry (GC/MS) detection. It was interesting that 25 esters and 2 alcohols among 30 banana volatile organic compounds (VOCs) identified and 4 esters and 7 alcohols among 13 identified VOCs of fermented glutinous rice were selectively sampled by ANW SPME fiber coatings. Furthermore, new analytical methods for the determination of some typical volatile esters and alcohols from banana and fermented glutinous rice samples at specific storage or brewing phases were developed and validated. Good recoveries for banana and fermented glutinous rice samples were achieved in range of 108-115% with relative standard deviations (RSDs) of 2.6-6.7% and 80.0-91.8% with RSDs of 0.3-1.3% (n=3), respectively. This work proposed a novel and efficient gas sampling technique of ANW SPME which was quite suitable for ultra-selectively sampling trace volatile esters and alcohols from complicated food samples. Copyright © 2013 Elsevier B.V. All rights reserved.
Gómez-Álvarez, Sandra; Porta-Oltra, Begoña; Hernandez-Griso, Marta; Pérez-Labaña, Francisca; Climente-Martí, Mónica
2016-01-01
to assess the impact of two closed-system drug transfer device on the local and environmental contamination and preparation times in the process of preparation of parenteral chemotherapy compared to the standard system. prospective observational study. Two different closed- systems providers, Care Fusion® and Icu Medical®, were compared to standard preparation. 15 nurses of Pharmacy Department prepared 5 preparations each one, one with the standard procedure and four using closed-systems. To evaluate the contamination, a fluorescein solution 0.5% was prepared. Two kind of contamination were evaluated, local (three points connection: closed-system connect vial, syringe and final infusion bags) and environmental (gloves and countertop). Percentage of contaminated preparations was obtained in each one. Time taken by each nurse in each preparation was recorded. 75 preparations were prepared. Local contamination was reduced 21% and 75% in closed-system Icu Medical® and Care Fusion® respectively. Care Fusion® closed system, local contamination was significantly lower than the standard system to the vial, syringe and final package, while Icu Medical® closed-systems only was significantly lower in the connection to the vial. Time of preparation was increased significantly with the use of closed-system between 23.4 and 30.5 seconds. both closed-systems drug transfer device have shown an improvement in contamination than the use of the standard system. However, preparation time has been significantly increased with the use of both systems. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.
ERIC Educational Resources Information Center
Lynch, Kristie
2013-01-01
The New York State Physical Education Learning Standards for K-12 students were transformed into a survey administered to a sample of teachers of physical education (N = 261), ascertaining their ratings of their knowledge, ability/skill, education/training, and attitudes on the importance of future professionals receiving training to teach…
Standard Operating Procedure for Accelerated Corrosion Testing at ARL
2017-11-01
report are not to be construed as an official Department of the Army position unless so designated by other authorized documents. Citation of...Parameters 2 4. Evaluation 3 4.1 Preparation for Rating 3 4.2 Evaluation of Creepage from Scribe 3 4.3 Evaluation of Unscribed Areas 4 5...operational parameters of the chamber. Test sample evaluations are explained with respect to both corrosion originating from the scribe and
ERIC Educational Resources Information Center
Lord, Janet E.
This document is designed to prepare advocates in the international disability community for productive participation in the development of international conventions on the human rights of people with disabilities. Knowledge of the standard categories of international law provisions will help participants address issues related to the structure of…
Environmental Assisted Cracking in High Hardness Armor Steel
1985-09-01
Longitudinal and transverse tension tests (ASTM E8-81) utilizing flat dogbane specimens, and subsize Charpy impact tests (ASTM 23-81) were performed on part...had been obtained. Longitudinal and transverse tension tests (ASTM E8-81) utilizing flat dogbane specimens, and subsize Charpy impact tests (ASTM 23... Charpy and tensile bar surfaces. All of the optical metallography samples were prepared using standard metallographic practices. The optical specimens
Duan, X; Ning, M
2015-01-01
Preparation and in vitro/in vivo evaluation of mifepristone intravaginal ring formulations were investigated. In the present study, it is reported that a mifepristone intravaginal ring of reservoir design comprising of a mifepristone silicone elastomer core enclosed in a silicone layer. During the preparation of intravaginal ring solid dispersion method was employed which improved the release rate of drug from the intravaginal ring. In vitro release studies performed under sink conditions and the released drug amounts were estimated using UV spectrometry at 310 nm. In addition, the in vivo release profile of in-house devices was evaluated in female New Zealand white rabbits. The rabbit plasma samples were processed and analyzed using a validated HPLC-MS method. Norgestrel was used as internal standard, and plasma samples contained mifepristone and internal standard were deproteinized, and then subjected to HPLC-MS analysis under condition of electrospray ionization in the selected ion monitoring mode. The drug release from intravaginal ring made in house was constant for 21 days in rabbits, which suggested the mifepristone intravaginal ring release system would be useful in clinical practice in the future. The result indicated the in vitro/in vivo correlation is perfect, which explained in vitro release analysis method developed was feasible.
Simonsen, H; Jensen, U G
1999-12-01
Quantitative analysis of amino acids (AA) and acylcarnitines using tandem mass spectrometry is an emerging technology used to screen neonatal dried blood spot samples for disorders in the metabolism of AA, organic acids and fatty acids. This paper provides a brief review of some of the technically oriented issues which emerged at the 4th meeting of the International Society for Neonatal Screening in Stockholm, 1999. The information covers sample preparation, instrumentation, data acquistion modes, internal standards, interpretation, confounding factors and practical screening experience.
Procedure for Uranium-Molybdenum Density Measurements and Porosity Determination
DOE Office of Scientific and Technical Information (OSTI.GOV)
Prabhakaran, Ramprashad; Devaraj, Arun; Joshi, Vineet V.
2016-08-13
The purpose of this document is to provide guidelines for preparing uranium-molybdenum (U-Mo) specimens, performing density measurements, and computing sample porosity. Typical specimens (solids) will be sheared to small rectangular foils, disks, or pieces of metal. A mass balance, solid density determination kit, and a liquid of known density will be used to determine the density of U-Mo specimens using the Archimedes principle. A standard test weight of known density would be used to verify proper operation of the system. By measuring the density of a U-Mo sample, it is possible to determine its porosity.
Quantification of protein concentration using UV absorbance and Coomassie dyes.
Noble, James E
2014-01-01
The measurement of a solubilized protein concentration in solution is an important assay in biochemistry research and development labs for applications ranging from enzymatic studies to providing data for biopharmaceutical lot release. Spectrophotometric protein quantification assays are methods that use UV and visible spectroscopy to rapidly determine the concentration of protein, relative to a standard, or using an assigned extinction coefficient. Where multiple samples need measurement, and/or the sample volume and concentration is limited, preparations of the Coomassie dye commonly known as the Bradford assay can be used. © 2014 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bank, Tracy L.; Roth, Elliot A.; Tinker, Phillip
2016-04-17
Inductively Coupled Plasma Mass Spectrometry (ICP-MS) is used to measure the concentrations of rare earth elements (REE) in certified standard reference materials including shale and coal. The instrument used in this study is a Perkin Elmer Nexion 300D ICP-MS. The goal of the study is to identify sample preparation and operating conditions that optimized recovery of each element of concern. Additionally, the precision and accuracy of the technique are summarized and the drawbacks and limitations of the method are outlined.
Percy, Andrew J; Mohammed, Yassene; Yang, Juncong; Borchers, Christoph H
2015-12-01
An increasingly popular mass spectrometry-based quantitative approach for health-related research in the biomedical field involves the use of stable isotope-labeled standards (SIS) and multiple/selected reaction monitoring (MRM/SRM). To improve inter-laboratory precision and enable more widespread use of this 'absolute' quantitative technique in disease-biomarker assessment studies, methods must be standardized. Results/methodology: Using this MRM-with-SIS-peptide approach, we developed an automated method (encompassing sample preparation, processing and analysis) for quantifying 76 candidate protein markers (spanning >4 orders of magnitude in concentration) in neat human plasma. The assembled biomarker assessment kit - the 'BAK-76' - contains the essential materials (SIS mixes), methods (for acquisition and analysis), and tools (Qualis-SIS software) for performing biomarker discovery or verification studies in a rapid and standardized manner.
Wu, Yiman; Li, Liang
2012-12-18
For mass spectrometry (MS)-based metabolomics, it is important to use the same amount of starting materials from each sample to compare the metabolome changes in two or more comparative samples. Unfortunately, for biological samples, the total amount or concentration of metabolites is difficult to determine. In this work, we report a general approach of determining the total concentration of metabolites based on the use of chemical labeling to attach a UV absorbent to the metabolites to be analyzed, followed by rapid step-gradient liquid chromatography (LC) UV detection of the labeled metabolites. It is shown that quantification of the total labeled analytes in a biological sample facilitates the preparation of an appropriate amount of starting materials for MS analysis as well as the optimization of the sample loading amount to a mass spectrometer for achieving optimal detectability. As an example, dansylation chemistry was used to label the amine- and phenol-containing metabolites in human urine samples. LC-UV quantification of the labeled metabolites could be optimally performed at the detection wavelength of 338 nm. A calibration curve established from the analysis of a mixture of 17 labeled amino acid standards was found to have the same slope as that from the analysis of the labeled urinary metabolites, suggesting that the labeled amino acid standard calibration curve could be used to determine the total concentration of the labeled urinary metabolites. A workflow incorporating this LC-UV metabolite quantification strategy was then developed in which all individual urine samples were first labeled with (12)C-dansylation and the concentration of each sample was determined by LC-UV. The volumes of urine samples taken for producing the pooled urine standard were adjusted to ensure an equal amount of labeled urine metabolites from each sample was used for the pooling. The pooled urine standard was then labeled with (13)C-dansylation. Equal amounts of the (12)C-labeled individual sample and the (13)C-labeled pooled urine standard were mixed for LC-MS analysis. This way of concentration normalization among different samples with varying concentrations of total metabolites was found to be critical for generating reliable metabolome profiles for comparison.
NASA Astrophysics Data System (ADS)
Ortiz Montalvo, D. L.; Kirchstetter, T. W.; Soto-García, L. L.; Mayol-Bracero, O. L.
2006-12-01
Combustion generated particles are a concern to both climate and public health due to their ability to scatter and absorb solar radiation and alter cloud properties, and because they are small enough to be inhaled and deposit in the lungs where they may cause respiratory and other health problems. Specific concern is focused on particles that originate from the combustion of diesel fuel. Diesels particles are composed mainly of carbonaceous material, especially in locations where diesel fuel sulfur is low. These particles are black due to the strongly light absorbing nature of the refractory carbon components, appropriately called black carbon (BC). This research project focuses on the uncertainty in the measurement of BC mass concentration, which is typically determined by analysis of particles collected on a filter using a thermal-optical analysis (TOA) method. Many studies have been conducted to examine the accuracy of the commonly used variations of the TOA method, which vary in their sample heating protocol, carrier gas, and optical measurement. These studies show that BC measurements are inaccurate due to the presence of organic carbon (OC) in the aerosols. OC may co-evolve with BC or char to form BC during analysis, both of which make it difficult to distinguish between the OC and BC in the sample. The goal of this study is to develop the capability of producing standard samples of known amounts of BC, either alone or mixed with other aerosol constituents, and then evaluate which TOA methods accurately determine the BC amount. An inverted diffusion flame of methane and air was used to produce particle samples containing only BC as well as samples of BC mixed with humic acid (HA). Our study found that HA is light absorbing and catalyzes the combustion of BC. It is expected that both of these attributes will challenge the ability of TOA methods in distinguishing between OC and BC, such as the simple two step TOA method which relies solely on temperature to distinguish between OC and BC. These samples were analyzed using two TOA methods to compare the estimates of BC concentration. Future work will focus on the preparation of a variety of BC standards and comparing measurements of the prepared samples using a range of other TOA methods.
Granica, Sebastian; Piwowarski, Jakub P; Kiss, Anna K
2014-01-01
Lythri salicariaeherba is a pharmacopoeial plant material used by patients in the form of infusions in the treatment of acute diarrhoea. According to its pharmacopoeial monograph it is standardised for total tannin content, which should be not less than 5.0% using pyrogallol as a standard. Previous studies have shown that aqueous extracts from Lythri herba contain mainly ellagitannins among which vescalagin, castalagin and salicarinins A and B are dominating constituents. To develop and validate an efficient UHPLC coupled with a charged aerosol detector (CAD) method for quantification of four major ellagitannins in Lythri salicariaeherba and in one commercial preparation. Extraction conditions of ellagitannins from plant material were optimised. The relative response factors for vescalagin, castalagin and salicarinins A and B using gallic acid as an external standard were determined for the CAD detector. Then, a UHPLC method for quantification of ellagitannins was developed and validated. Four major ellagitannins were quantified in four samples of Lythri herba and in one commercial preparation. The sum of ellagitannins for each sample was determined, which varied from 30.66 to 48.80 mg/g of raw material and 16.57 mg per capsule for the preparation investigated. The first validated UHPLC/CAD UHPLC-CAD method for quantification of four major ellagitannins was developed. The universality of the CAD response was evaluated and it is shown that although all compounds analysed have similar structures their CAD response differs significantly. Copyright © 2013 John Wiley & Sons, Ltd.
Siddiqui, Mohd Farhan; Kim, Soocheol; Jeon, Hyoil; Kim, Taeho; Joo, Chulmin; Park, Seungkyung
2018-03-04
Conventional methods for analyzing heavy metal contamination in soil and water generally require laboratory equipped instruments, complex procedures, skilled personnel and a significant amount of time. With the advancement in computing and multitasking performances, smartphone-based sensors potentially allow the transition of the laboratory-based analytical processes to field applicable, simple methods. In the present work, we demonstrate the novel miniaturized setup for simultaneous sample preparation and smartphone-based optical sensing of arsenic As(III) in the contaminated soil. Colorimetric detection protocol utilizing aptamers, gold nanoparticles and NaCl have been optimized and tested on the PDMS-chip to obtain the high sensitivity with the limit of detection of 0.71 ppm (in the sample) and a correlation coefficient of 0.98. The performance of the device is further demonstrated through the comparative analysis of arsenic-spiked soil samples with standard laboratory method, and a good agreement with a correlation coefficient of 0.9917 and the average difference of 0.37 ppm, are experimentally achieved. With the android application on the device to run the experiment, the whole process from sample preparation to detection is completed within 3 hours without the necessity of skilled personnel. The approximate cost of setup is estimated around 1 USD, weight 55 g. Therefore, the presented method offers the simple, rapid, portable and cost-effective means for onsite sensing of arsenic in soil. Combined with the geometric information inside the smartphones, the system will allow the monitoring of the contamination status of soils in a nation-wide manner.
Vogeser, Michael; Spöhrer, Ute
2006-01-01
Liquid chromatography tandem-mass spectrometry (LC-MS/MS) is an efficient technology for routine determination of immunosuppressants in whole blood; however, time-consuming manual sample preparation remains a significant limitation of this technique. Using a commercially available robotic pipetting system (Tecan Freedom EVO), we developed an automated sample-preparation protocol for quantification of tacrolimus in whole blood by LC-MS/MS. Barcode reading, sample resuspension, transfer of whole blood aliquots into a deep-well plate, addition of internal standard solution, mixing, and protein precipitation by addition of an organic solvent is performed by the robotic system. After centrifugation of the plate, the deproteinized supernatants are submitted to on-line solid phase extraction, using column switching prior to LC-MS/MS analysis. The only manual actions within the entire process are decapping of the tubes, and transfer of the deep-well plate from the robotic system to a centrifuge and finally to the HPLC autosampler. Whole blood pools were used to assess the reproducibility of the entire analytical system for measuring tacrolimus concentrations. A total coefficient of variation of 1.7% was found for the entire automated analytical process (n=40; mean tacrolimus concentration, 5.3 microg/L). Close agreement between tacrolimus results obtained after manual and automated sample preparation was observed. The analytical system described here, comprising automated protein precipitation, on-line solid phase extraction and LC-MS/MS analysis, is convenient and precise, and minimizes hands-on time and the risk of mistakes in the quantification of whole blood immunosuppressant concentrations compared to conventional methods.
NASA Astrophysics Data System (ADS)
Paiè, Petra; Bassi, Andrea; Bragheri, Francesca; Osellame, Roberto
2017-02-01
Selective plane illumination microscopy (SPIM) is an optical sectioning technique that allows imaging of biological samples at high spatio-temporal resolution. Standard SPIM devices require dedicated set-ups, complex sample preparation and accurate system alignment, thus limiting the automation of the technique, its accessibility and throughput. We present a millimeter-scaled optofluidic device that incorporates selective plane illumination and fully automatic sample delivery and scanning. To this end an integrated cylindrical lens and a three-dimensional fluidic network were fabricated by femtosecond laser micromachining into a single glass chip. This device can upgrade any standard fluorescence microscope to a SPIM system. We used SPIM on a CHIP to automatically scan biological samples under a conventional microscope, without the need of any motorized stage: tissue spheroids expressing fluorescent proteins were flowed in the microchannel at constant speed and their sections were acquired while passing through the light sheet. We demonstrate high-throughput imaging of the entire sample volume (with a rate of 30 samples/min), segmentation and quantification in thick (100-300 μm diameter) cellular spheroids. This optofluidic device gives access to SPIM analyses to non-expert end-users, opening the way to automatic and fast screening of a high number of samples at subcellular resolution.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-23
... specifications and operating instructions, if available, or standard operating procedures must be developed by... manufacturer's specifications and operating instructions, if available, or standard operating procedures must... operating specifications or standard operating procedures developed by the prepared feeds manufacturer be...
Welna, Maja; Szymczycha-Madeja, Anna
2014-04-01
Various sample preparation procedures, such as common wet digestions and alternatives based on solubilisation in aqua regia or tetramethyl ammonium hydroxide, were compared for the determination of the total Ba, Ca, Cr, Cd, Cu, Fe, Mg, Mn, Ni, P, Pb, Se, Sr and Zn contents in Brazil nuts using inductively coupled plasma optical emission spectrometry (ICP-OES). For measurement of Se, a hydride generation technique was used. The performance of these procedures was measured in terms of precision, accuracy and limits of detection of the elements. It was found that solubilisation in aqua regia gave the best results, i.e. limits of detection from 0.60 to 41.9 ng ml(-1), precision of 1.0-3.9% and accuracy better than 5%. External calibration with simple standard solutions could be applied for the analysis. The proposed procedure is simple, reduces sample handling, and minimises the time and reagent consumption. Thus, this can be a vital alternative to traditional sample treatment approaches based on the total digestion with concentrated reagents. A phenomenon resulting from levels of Ba, Se and Sr in Brazil nuts was also discussed.
NASA Astrophysics Data System (ADS)
Jakopic, Rozle; Richter, Stephan; Kühn, Heinz; Benedik, Ljudmila; Pihlar, Boris; Aregbe, Yetunde
2009-01-01
A sample preparation procedure for isotopic measurements using thermal ionization mass spectrometry (TIMS) was developed which employs the technique of carburization of rhenium filaments. Carburized filaments were prepared in a special vacuum chamber in which the filaments were exposed to benzene vapour as a carbon supply and carburized electrothermally. To find the optimal conditions for the carburization and isotopic measurements using TIMS, the influence of various parameters such as benzene pressure, carburization current and the exposure time were tested. As a result, carburization of the filaments improved the overall efficiency by one order of magnitude. Additionally, a new "multi-dynamic" measurement technique was developed for Pu isotope ratio measurements using a "multiple ion counting" (MIC) system. This technique was combined with filament carburization and applied to the NBL-137 isotopic standard and samples of the NUSIMEP 5 inter-laboratory comparison campaign, which included certified plutonium materials at the ppt-level. The multi-dynamic measurement technique for plutonium, in combination with filament carburization, has been shown to significantly improve the precision and accuracy for isotopic analysis of environmental samples with low-levels of plutonium.
Moein, Mohammad Mahdi; Jabbar, Dunia; Colmsjö, Anders; Abdel-Rehim, Mohamed
2014-10-31
In the present work, a needle trap utilizing a molecularly imprinted sol-gel xerogel was prepared for the on-line microextraction of bilirubin from plasma and urine samples. Each prepared needle could be used for approximately one hundred extractions before it was discarded. Imprinted and non-imprinted sol-gel xerogel were applied for the extraction of bilirubin from plasma and urine samples. The produced molecularly imprinted sol-gel xerogel polymer showed high binding capacity and fast adsorption/desorption kinetics for bilirubin in plasma and urine samples. The adsorption capacity of molecularly imprinted sol-gel xerogel polymer was approximately 60% higher than that of non-imprinted polymer. The effect of the conditioning, washing and elution solvents, pH, extraction time, adsorption capacity and imprinting factor were investigated. The limit of detection and the lower limit of quantification were set to 1.6 and 5nmolL(-1), respectively using plasma or urine samples. The standard calibration curves were obtained within the concentration range of 5-1000nmolL(-1) in both plasma and urine samples. The coefficients of determination values (R(2)) were ≥0.998 for all runs. The extraction recovery was approximately 80% for BR in the human plasma and urine samples. Copyright © 2014 Elsevier B.V. All rights reserved.