Frazier, Melanie; Miller, A. Whitman; Lee, Henry; Reusser, Deborah A.
2013-01-01
Discharge from the ballast tanks of ships is one of the primary vectors of nonindigenous species in marine environments. To mitigate this environmental and economic threat, international, national, and state entities are establishing regulations to limit the concentration of living organisms that may be discharged from the ballast tanks of ships. The proposed discharge standards have ranged from zero detectable organisms to 3. If standard sampling methods are used, verifying whether ballast discharge complies with these stringent standards will be challenging due to the inherent stochasticity of sampling. Furthermore, at low concentrations, very large volumes of water must be sampled to find enough organisms to accurately estimate concentration. Despite these challenges, adequate sampling protocols comprise a critical aspect of establishing standards because they help define the actual risk level associated with a standard. A standard that appears very stringent may be effectively lax if it is paired with an inadequate sampling protocol. We describe some of the statistical issues associated with sampling at low concentrations to help regulators understand the uncertainties of sampling as well as to inform the development of sampling protocols that ensure discharge standards are adequately implemented.
STANDARD MEASUREMENT PROTOCOLS - FLORIDA RADON RESEARCH PROGRAM
The manual, in support of the Florida Radon Research Program, contains standard protocols for key measurements where data quality is vital to the program. t contains two sections. he first section, soil measurements, contains field sampling protocols for soil gas permeability and...
Sampling protocol for post-landfall Deepwater Horizon oil release, Gulf of Mexico, 2010
Wilde, F.D.; Skrobialowski, S.C.; Hart, J.S.
2010-01-01
The protocols and procedures described in this report are designed to be used by U.S. Geological Survey (USGS) field teams for the collection of environmental data and samples in coastal areas affected by the 2010 Deepwater Horizon oil spill in the Gulf of Mexico. This sampling protocol focuses specifically on sampling for water, sediments, benthic invertebrates, and microorganisms (ambient bacterial populations) after shoreline arrival of petroleum-associated product on beach, barrier island, and wetland environments of the Gulf of Mexico coastal states. Deployment to sampling sites, site setup, and sample collection in these environments necessitates modifications to standard USGS sampling procedures in order to address the regulatory, logistical, and legal requirements associated with samples collected in oil-impacted coastal areas. This document, therefore, has been written as an addendum to the USGS National Field Manual for the Collection of Water-Quality Data (NFM) (http://pubs.water.usgs.gov/twri9A/), which provides the basis for training personnel in the use of standard USGS sampling protocols. The topics covered in this Gulf of Mexico oil-spill sampling protocol augment NFM protocols for field-deployment preparations, health and safety precautions, sampling and quality-assurance procedures, and decontamination requirements under potentially hazardous environmental conditions. Documentation procedures and maintenance of sample integrity by use of chain-of-custody procedures also are described in this protocol.
Petersen, James C.; Justus, B.G.; Dodd, H.R.; Bowles, D.E.; Morrison, L.W.; Williams, M.H.; Rowell, G.A.
2008-01-01
Buffalo National River located in north-central Arkansas, and Ozark National Scenic Riverways, located in southeastern Missouri, are the two largest units of the National Park Service in the Ozark Plateaus physiographic province. The purpose of this report is to provide a protocol that will be used by the National Park Service to sample fish communities and collect related water-quality, habitat, and stream discharge data of Buffalo National River and Ozark National Scenic Riverways to meet inventory and long-term monitoring objectives. The protocol includes (1) a protocol narrative, (2) several standard operating procedures, and (3) supplemental information helpful for implementation of the protocol. The protocol narrative provides background information about the protocol such as the rationale of why a particular resource or resource issue was selected for monitoring, information concerning the resource or resource issue of interest, a description of how monitoring results will inform management decisions, and a discussion of the linkages between this and other monitoring projects. The standard operating procedures cover preparation, training, reach selection, water-quality sampling, fish community sampling, physical habitat collection, measuring stream discharge, equipment maintenance and storage, data management and analysis, reporting, and protocol revision procedures. Much of the information in the standard operating procedures was gathered from existing protocols of the U.S. Geological Survey National Water Quality Assessment program or other sources. Supplemental information that would be helpful for implementing the protocol is included. This information includes information on fish species known or suspected to occur in the parks, sample sites, sample design, fish species traits, index of biotic integrity metrics, sampling equipment, and field forms.
2014-07-01
Analyzer TCE Trichloroethene USEPA U.S. Environmental Protection Agency V- PDB Vienna - Pee Dee Belemnite V-SMOW Vienna – Standard Mean Ocean Water ... PDB ) for carbon, Standard Mean Ocean Chloride (SMOC) for chlorine, and Vienna-Standard Mean Ocean Water (V-SMOW) for hydrogen. CSIA Protocol for...7 3.3 INDOOR AIR SAMPLING LOCATIONS ............................................................ 8 3.4 COLLECTION OF WATER SAMPLES
Aboal, J R; Boquete, M T; Carballeira, A; Casanova, A; Debén, S; Fernández, J A
2017-05-01
In this study we examined 6080 data gathered by our research group during more than 20 years of research on the moss biomonitoring technique, in order to quantify the variability generated by different aspects of the protocol and to calculate the overall measurement uncertainty associated with the technique. The median variance of the concentrations of different pollutants measured in moss tissues attributed to the different methodological aspects was high, reaching values of 2851 (ng·g -1 ) 2 for Cd (sample treatment), 35.1 (μg·g -1 ) 2 for Cu (sample treatment), 861.7 (ng·g -1 ) 2 and for Hg (material selection). These variances correspond to standard deviations that constitute 67, 126 and 59% the regional background levels of these elements in the study region. The overall measurement uncertainty associated with the worst experimental protocol (5 subsamples, refrigerated, washed, 5 × 5 m size of the sampling area and once a year sampling) was between 2 and 6 times higher than that associated with the optimal protocol (30 subsamples, dried, unwashed, 20 × 20 m size of the sampling area and once a week sampling), and between 1.5 and 7 times higher than that associated with the standardized protocol (30 subsamples and once a year sampling). The overall measurement uncertainty associated with the standardized protocol could generate variations of between 14 and 47% in the regional background levels of Cd, Cu, Hg, Pb and Zn in the study area and much higher levels of variation in polluted sampling sites. We demonstrated that although the overall measurement uncertainty of the technique is still high, it can be reduced by using already well defined aspects of the protocol. Further standardization of the protocol together with application of the information on the overall measurement uncertainty would improve the reliability and comparability of the results of different biomonitoring studies, thus extending use of the technique beyond the context of scientific research. Copyright © 2017 Elsevier Ltd. All rights reserved.
A MORE COST-EFFECTIVE EMAP-ESTUARIES BENTHIC MACROFAUNAL SAMPLING PROTOCOL
The standard benthic macrofaunal sampling protocol in the U.S. Environmental Protection Agency's Pacific Coast Environmental Monitoring and Assessment Program (EMAP) is to collect a minimum of 30 random benthic samples per reporting unit (e.g., estuary) using a 0.1 m2 grab and to...
This protocol describes how quality control samples should be handled in the field, and was designed as a quick reference source for the field staff. The protocol describes quality control samples for air-VOCs, air-particles, water samples, house dust, soil, urine, blood, hair, a...
NHEXAS PHASE I ARIZONA STUDY--LIST OF STANDARD OPERATING PROCEDURES
This document lists available protocols and SOPs for the NHEXAS Phase I Arizona study. It identifies protocols and SOPs for the following study components: (1) Sample collection and field operations, (2) Sample analysis, (3) General laboratory procedures, (4) Quality Assurance, (...
Human immunodeficiency virus bDNA assay for pediatric cases.
Avila, M M; Liberatore, D; Martínez Peralta, L; Biglione, M; Libonatti, O; Coll Cárdenas, P; Hodara, V L
2000-01-01
Techniques to quantify plasma HIV-1 RNA viral load (VL) are commercially available, and they are adequate for monitoring adults infected by HIV and treated with antiretroviral drugs. Little experience on HIV VL has been reported in pediatric cases. In Argentina, the evaluation of several assays for VL in pediatrics are now being considered. To evaluate the pediatric protocol for bDNA assay in HIV-infected children, 25 samples from HIV-infected children (according to CDC criteria for pediatric AIDS) were analyzed by using Quantiplex HIV RNA 2.0 Assay (Chiron Corporation) following the manufacturer's recommendations in a protocol that uses 50 microliters of patient's plasma (sensitivity: 10,000 copies/ml). When HIV-RNA was not detected, samples were run with the 1 ml standard bDNA protocol (sensitivity: 500 HIV-RNA c/ml). Nine samples belonged to infants under 12 months of age (group A) and 16 were over 12 months (group B). All infants under one year of age had high HIV-RNA copies in plasma. VL ranged from 30,800 to 2,560,000 RNA copies/ml (median = 362,000 c/ml) for group A and < 10,000 to 554,600 c/ml (median = < 10,000) for group B. Only 25% of children in group B had detectable HIV-RNA. By using the standard test of quantification, none of the patients had non detectable HIV-RNA, ranging between 950 and 226,200 c/ml for group B (median = 23,300 RNA c/ml). The suggested pediatric protocol could be useful in children under 12 months of age, but 1 ml standard protocol must be used for older children. Samples with undetectable results from children under one year of age should be repeated using the standard protocol.
U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--LIST OF STANDARD OPERATING PROCEDURES
This document lists available protocols and SOPs for the U.S.-Mexico Border Program study. It identifies protocols and SOPs for the following study components: (1) Sample collection and field operations, (2) Sample analysis, (3) General laboratory procedures, (4) Quality Assuranc...
21 CFR 660.46 - Samples; protocols; official release.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Samples; protocols; official release. 660.46 Section 660.46 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Hepatitis B Surface...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abeykoon, A. M. Milinda; Hu, Hefei; Wu, Lijun
2015-01-30
Different protocols for calibrating electron pair distribution function (ePDF) measurements are explored and described for quantitative studies on nanomaterials. It is found that the most accurate approach to determine the camera length is to use a standard calibration sample of Au nanoparticles from the National Institute of Standards and Technology. Different protocols for data collection are also explored, as are possible operational errors, to find the best approaches for accurate data collection for quantitative ePDF studies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abeykoon, A. M. Milinda; Hu, Hefei; Wu, Lijun
2015-02-01
We explore and describe different protocols for calibrating electron pair distribution function (ePDF) measurements for quantitative studies on nano-materials. We find the most accurate approach to determine the camera-length is to use a standard calibration sample of Au nanoparticles from National Institute of Standards and Technology. Different protocols for data collection are also explored, as are possible operational errors, to find the best approaches for accurate data collection for quantitative ePDF studies.
Ozarda, Yesim; Ichihara, Kiyoshi; Barth, Julian H; Klee, George
2013-05-01
The reference intervals (RIs) given in laboratory reports have an important role in aiding clinicians in interpreting test results in reference to values of healthy populations. In this report, we present a proposed protocol and standard operating procedures (SOPs) for common use in conducting multicenter RI studies on a national or international scale. The protocols and consensus on their contents were refined through discussions in recent C-RIDL meetings. The protocol describes in detail (1) the scheme and organization of the study, (2) the target population, inclusion/exclusion criteria, ethnicity, and sample size, (3) health status questionnaire, (4) target analytes, (5) blood collection, (6) sample processing and storage, (7) assays, (8) cross-check testing, (9) ethics, (10) data analyses, and (11) reporting of results. In addition, the protocol proposes the common measurement of a panel of sera when no standard materials exist for harmonization of test results. It also describes the requirements of the central laboratory, including the method of cross-check testing between the central laboratory of each country and local laboratories. This protocol and the SOPs remain largely exploratory and may require a reevaluation from the practical point of view after their implementation in the ongoing worldwide study. The paper is mainly intended to be a basis for discussion in the scientific community.
Evaluation of a High Throughput Starch Analysis Optimised for Wood
Bellasio, Chandra; Fini, Alessio; Ferrini, Francesco
2014-01-01
Starch is the most important long-term reserve in trees, and the analysis of starch is therefore useful source of physiological information. Currently published protocols for wood starch analysis impose several limitations, such as long procedures and a neutralization step. The high-throughput standard protocols for starch analysis in food and feed represent a valuable alternative. However, they have not been optimised or tested with woody samples. These have particular chemical and structural characteristics, including the presence of interfering secondary metabolites, low reactivity of starch, and low starch content. In this study, a standard method for starch analysis used for food and feed (AOAC standard method 996.11) was optimised to improve precision and accuracy for the analysis of starch in wood. Key modifications were introduced in the digestion conditions and in the glucose assay. The optimised protocol was then evaluated through 430 starch analyses of standards at known starch content, matrix polysaccharides, and wood collected from three organs (roots, twigs, mature wood) of four species (coniferous and flowering plants). The optimised protocol proved to be remarkably precise and accurate (3%), suitable for a high throughput routine analysis (35 samples a day) of specimens with a starch content between 40 mg and 21 µg. Samples may include lignified organs of coniferous and flowering plants and non-lignified organs, such as leaves, fruits and rhizomes. PMID:24523863
Fallon, Nevada FORGE Fluid Geochemistry
Blankenship, Doug; Ayling, Bridget
2018-03-13
Fluid geochemistry analysis for wells supporting the Fallon FORGE project. Samples were collected from geothermal wells using standard geothermal water sampling techniques, including filtration and acidification of the cation sample to pH < 2 prior to geochemical analysis. Analyses after 2005 were done in reputable commercial laboratories that follow standard protocols for aqueous chemistry analysis.
The purpose of this protocol is to provide guidelines for the analysis of hair samples for total mercury by cold vapor atomic fluorescence (CVAFS) spectrometry. This protocol describes the methodology and all other analytical aspects involved in the analysis. Keywords: hair; s...
Validation of a standardized extraction method for formalin-fixed paraffin-embedded tissue samples.
Lagheden, Camilla; Eklund, Carina; Kleppe, Sara Nordqvist; Unger, Elizabeth R; Dillner, Joakim; Sundström, Karin
2016-07-01
Formalin-fixed paraffin-embedded (FFPE) samples can be DNA-extracted and used for human papillomavirus (HPV) genotyping. The xylene-based gold standard for extracting FFPE samples is laborious, suboptimal and involves health hazards for the personnel involved. To compare extraction with the standard xylene method to a xylene-free method used in an HPV LabNet Global Reference Laboratory at the Centers for Disease Control (CDC); based on a commercial method with an extra heating step. Fifty FFPE samples were randomly selected from a national audit of all cervical cancer cases diagnosed in Sweden during 10 years. For each case-block, a blank-block was sectioned, as a control for contamination. For xylene extraction, the standard WHO Laboratory Manual protocol was used. For the CDC method, the manufacturers' protocol was followed except for an extra heating step, 120°C for 20min. Samples were extracted and tested in parallel with β-globin real-time PCR, HPV16 real-time PCR and HPV typing using modified general primers (MGP)-PCR and Luminex assays. For a valid result the blank-block had to be betaglobin-negative in all tests and the case-block positive for beta-globin. Overall, detection was improved with the heating method and the amount of HPV-positive samples increased from 70% to 86% (p=0.039). For all samples where HPV type concordance could be evaluated, there was 100% type concordance. A xylene-free and robust extraction method for HPV-DNA typing in FFPE material is currently in great demand. Our proposed standardized protocol appears to be generally useful. Copyright © 2016. Published by Elsevier B.V.
Rani, Anupama; Sharma, Vivek; Arora, Sumit; Lal, Darshan; Kumar, Anil
2015-04-01
Detection of milk fat adulteration with foreign fats/oils continues to be a challenge for the dairy industry as well as food testing laboratories, especially in the present scenario of rampant adulteration using the scientific knowledge by unscrupulous persons involved in the trade. In the present investigation a rapid reversed-phase thin layer chromatographic (RP-TLC) protocol was standardized to ascertain the purity of milk fat. RP-TLC protocol did not show any false positive results in the genuine ghee (clarified butter fat) samples of known origin. Adulteration of ghee with coconut oil up to 7. 5 %, soybean oil, sunflower oil and groundnut oil up to 1 %, while, designer oil up to 2 % level could be detected using the standardized RP-TLC protocol. The protocol standardized is rapid and convenient to use.
Aloisio, Michelangelo; Bortot, Barbara; Gandin, Ilaria; Severini, Giovanni Maria; Athanasakis, Emmanouil
2017-02-01
Chimerism status evaluation of post-allogeneic hematopoietic stem cell transplantation samples is essential to predict post-transplant relapse. The most commonly used technique capable of detecting small increments of chimerism is quantitative real-time PCR. Although this method is already used in several laboratories, previously described protocols often lack sensitivity and the amount of the DNA required for each chimerism analysis is too high. In the present study, we compared a novel semi-nested allele-specific real-time PCR (sNAS-qPCR) protocol with our in-house standard allele-specific real-time PCR (gAS-qPCR) protocol. We selected two genetic markers and analyzed technical parameters (slope, y-intercept, R2, and standard deviation) useful to determine the performances of the two protocols. The sNAS-qPCR protocol showed better sensitivity and precision. Moreover, the sNAS-qPCR protocol requires, as input, only 10 ng of DNA, which is at least 10-fold less than the gAS-qPCR protocols described in the literature. Finally, the proposed sNAS-qPCR protocol could prove very useful for performing chimerism analysis with a small amount of DNA, as in the case of blood cell subsets.
Novel methodology to isolate microplastics from vegetal-rich samples.
Herrera, Alicia; Garrido-Amador, Paloma; Martínez, Ico; Samper, María Dolores; López-Martínez, Juan; Gómez, May; Packard, Theodore T
2018-04-01
Microplastics are small plastic particles, globally distributed throughout the oceans. To properly study them, all the methodologies for their sampling, extraction, and measurement should be standardized. For heterogeneous samples containing sediments, animal tissues and zooplankton, several procedures have been described. However, definitive methodologies for samples, rich in algae and plant material, have not yet been developed. The aim of this study was to find the best extraction protocol for vegetal-rich samples by comparing the efficacies of five previously described digestion methods, and a novel density separation method. A protocol using 96% ethanol for density separation was better than the five digestion methods tested, even better than using H 2 O 2 digestion. As it was the most efficient, simple, safe and inexpensive method for isolating microplastics from vegetal rich samples, we recommend it as a standard separation method. Copyright © 2018 Elsevier Ltd. All rights reserved.
Hoffmayer, Eric R; Hendon, Jill M; Parsons, Glenn R; Driggers, William B; Campbell, Matthew D
2015-10-01
Elasmobranch stress responses are traditionally measured in the field by either singly or serially sampling an animal after a physiologically stressful event. Although capture and handling techniques are effective at inducing a stress response, differences in protocols could affect the degree of stress experienced by an individual, making meaningful comparisons between the protocols difficult, if not impossible. This study acutely stressed Atlantic sharpnose sharks, Rhizoprionodon terraenovae, by standardized capture (rod and reel) and handling methods and implemented either a single or serial blood sampling protocol to monitor four indicators of the secondary stress response. Single-sampled sharks were hooked and allowed to swim around the boat until retrieved for a blood sample at either 0, 15, 30, 45, or 60 min post-hooking. Serially sampled sharks were retrieved, phlebotomized, released while still hooked, and subsequently resampled at 15, 30, 45, and 60 min intervals post-hooking. Blood was analyzed for hematocrit, and plasma glucose, lactate, and osmolality levels. Although both single and serial sampling protocols resulted in an increase in glucose, no significant difference in glucose level was found between protocols. Serially sampled sharks exhibited cumulatively heightened levels for lactate and osmolality at all time intervals when compared to single-sampled animals at the same time. Maximal concentration differences of 217.5, 9.8, and 41.6 % were reported for lactate, osmolality, and glucose levels, respectively. Hematocrit increased significantly over time for the single sampling protocol but did not change significantly during the serial sampling protocol. The differences in resultant blood chemistry levels between implemented stress protocols and durations are significant and need to be considered when assessing stress in elasmobranchs.
Standardized protocols for quality control of MRM-based plasma proteomic workflows.
Percy, Andrew J; Chambers, Andrew G; Smith, Derek S; Borchers, Christoph H
2013-01-04
Mass spectrometry (MS)-based proteomics is rapidly emerging as a viable technology for the identification and quantitation of biological samples, such as human plasma--the most complex yet commonly employed biofluid in clinical analyses. The transition from a qualitative to quantitative science is required if proteomics is going to successfully make the transition to a clinically useful technique. MS, however, has been criticized for a lack of reproducibility and interlaboratory transferability. Currently, the MS and plasma proteomics communities lack standardized protocols and reagents to ensure that high-quality quantitative data can be accurately and precisely reproduced by laboratories across the world using different MS technologies. Toward addressing this issue, we have developed standard protocols for multiple reaction monitoring (MRM)-based assays with customized isotopically labeled internal standards for quality control of the sample preparation workflow and the MS platform in quantitative plasma proteomic analyses. The development of reference standards and their application to a single MS platform is discussed herein, along with the results from intralaboratory tests. The tests highlighted the importance of the reference standards in assessing the efficiency and reproducibility of the entire bottom-up proteomic workflow and revealed errors related to the sample preparation and performance quality and deficits of the MS and LC systems. Such evaluations are necessary if MRM-based quantitative plasma proteomics is to be used in verifying and validating putative disease biomarkers across different research laboratories and eventually in clinical laboratories.
A Tool for Estimating Variability in Wood Preservative Treatment Retention
Patricia K. Lebow; Adam M. Taylor; Timothy M. Young
2015-01-01
Composite sampling is standard practice for evaluation of preservative retention levels in preservative-treated wood. Current protocols provide an average retention value but no estimate of uncertainty. Here we describe a statistical method for calculating uncertainty estimates using the standard sampling regime with minimal additional chemical analysis. This tool can...
Monitoring fish distributions along electrofishing segments
Miranda, Leandro E.
2014-01-01
Electrofishing is widely used to monitor fish species composition and relative abundance in streams and lakes. According to standard protocols, multiple segments are selected in a body of water to monitor population relative abundance as the ratio of total catch to total sampling effort. The standard protocol provides an assessment of fish distribution at a macrohabitat scale among segments, but not within segments. An ancillary protocol was developed for assessing fish distribution at a finer scale within electrofishing segments. The ancillary protocol was used to estimate spacing, dispersion, and association of two species along shore segments in two local reservoirs. The added information provided by the ancillary protocol may be useful for assessing fish distribution relative to fish of the same species, to fish of different species, and to environmental or habitat characteristics.
Palomaki, Glenn E; Lee, Jo Ellen S; Canick, Jacob A; McDowell, Geraldine A; Donnenfeld, Alan E
2009-09-01
This statement is intended to augment the current general ACMG Standards and Guidelines for Clinical Genetics Laboratories and to address guidelines specific to first-trimester screening for Down syndrome. The aim is to provide the laboratory the necessary information to ensure accurate and reliable Down syndrome screening results given a screening protocol (e.g., combined first trimester and integrated testing). Information about various test combinations and their expected performance are provided, but other issues such as availability of reagents, patient interest in early test results, access to open neural tube defect screening, and availability of chorionic villus sampling are all contextual factors in deciding which screening protocol(s) will be selected by individual health care providers. Individual laboratories are responsible for meeting the quality assurance standards described by the Clinical Laboratory Improvement Act, the College of American Pathologists, and other regulatory agencies, with respect to appropriate sample documentation, assay validation, general proficiency, and quality control measures. These guidelines address first-trimester screening that includes ultrasound measurement and interpretation of nuchal translucency thickness and protocols that combine markers from both the first and second trimesters. Laboratories can use their professional judgment to make modification or additions.
Johanson, Helene C; Hyland, Valentine; Wicking, Carol; Sturm, Richard A
2009-04-01
We describe here a method for DNA elution from buccal cells and whole blood both collected onto Whatman FTA technology, using methanol fixation followed by an elution PCR program. Extracted DNA is comparable in quality to published Whatman FTA protocols, as judged by PCR-based genotyping. Elution of DNA from the dried sample is a known rate-limiting step in the published Whatman FTA protocol; this method enables the use of each 3-mm punch of sample for several PCR reactions instead of the standard, one PCR reaction per sample punch. This optimized protocol therefore extends the usefulness and cost effectiveness of each buccal swab sample collected, when used for nucleic acid PCR and genotyping.
Monsonis Centelles, Sandra; Hoefsloot, Huub C J; Khakimov, Bekzod; Ebrahimi, Parvaneh; Lind, Mads V; Kristensen, Mette; de Roo, Niels; Jacobs, Doris M; van Duynhoven, John; Cannet, Claire; Fang, Fang; Humpfer, Eberhard; Schäfer, Hartmut; Spraul, Manfred; Engelsen, Søren B; Smilde, Age K
2017-08-01
Lipoprotein profiling of human blood by 1 H nuclear magnetic resonance (NMR) spectroscopy is a rapid and promising approach to monitor health and disease states in medicine and nutrition. However, lack of standardization of measurement protocols has prevented the use of NMR-based lipoprotein profiling in metastudies. In this study, a standardized NMR measurement protocol was applied in a ring test performed across three different laboratories in Europe on plasma and serum samples from 28 individuals. Data was evaluated in terms of (i) spectral differences, (ii) differences in LPD predictions obtained using an existing prediction model, and (iii) agreement of predictions with cholesterol concentrations in high- and low-density lipoproteins (HDL and LDL) particles measured by standardized clinical assays. ANOVA-simultaneous component analysis (ASCA) of the ring test spectral ensemble that contains methylene and methyl peaks (1.4-0.6 ppm) showed that 97.99% of the variance in the data is related to subject, 1.62% to sample type (serum or plasma), and 0.39% to laboratory. This interlaboratory variation is in fact smaller than the maximum acceptable intralaboratory variation on quality control samples. It is also shown that the reproducibility between laboratories is good enough for the LPD predictions to be exchangeable when the standardized NMR measurement protocol is followed. With the successful implementation of this protocol, which results in reproducible prediction of lipoprotein distributions across laboratories, a step is taken toward bringing NMR more into scope of prognostic and diagnostic biomarkers, reducing the need for less efficient methods such as ultracentrifugation or high-performance liquid chromatography (HPLC).
Vogel, Adam P; Block, Susan; Kefalianos, Elaina; Onslow, Mark; Eadie, Patricia; Barth, Ben; Conway, Laura; Mundt, James C; Reilly, Sheena
2015-04-01
To investigate the feasibility of adopting automated interactive voice response (IVR) technology for remotely capturing standardized speech samples from stuttering children. Participants were 10 6-year-old stuttering children. Their parents called a toll-free number from their homes and were prompted to elicit speech from their children using a standard protocol involving conversation, picture description and games. The automated IVR system was implemented using an off-the-shelf telephony software program and delivered by a standard desktop computer. The software infrastructure utilizes voice over internet protocol. Speech samples were automatically recorded during the calls. Video recordings were simultaneously acquired in the home at the time of the call to evaluate the fidelity of the telephone collected samples. Key outcome measures included syllables spoken, percentage of syllables stuttered and an overall rating of stuttering severity using a 10-point scale. Data revealed a high level of relative reliability in terms of intra-class correlation between the video and telephone acquired samples on all outcome measures during the conversation task. Findings were less consistent for speech samples during picture description and games. Results suggest that IVR technology can be used successfully to automate remote capture of child speech samples.
Roug, Annette; Geoghegan, Claire; Wellington, Elizabeth; Miller, Woutrina A; Travis, Emma; Porter, David; Cooper, David; Clifford, Deana L; Mazet, Jonna A K; Parsons, Sven
2014-01-01
A real-time PCR protocol for detecting Mycobacterium bovis in feces was evaluated in bovine tuberculosis-infected African buffalo (Syncerus caffer). Fecal samples spiked with 1.42 × 10(3) cells of M. bovis culture/g and Bacille Calmette-Guérin standards with 1.58 × 10(1) genome copies/well were positive by real-time PCR but all field samples were negative.
Robust Sub-nanomolar Library Preparation for High Throughput Next Generation Sequencing.
Wu, Wells W; Phue, Je-Nie; Lee, Chun-Ting; Lin, Changyi; Xu, Lai; Wang, Rong; Zhang, Yaqin; Shen, Rong-Fong
2018-05-04
Current library preparation protocols for Illumina HiSeq and MiSeq DNA sequencers require ≥2 nM initial library for subsequent loading of denatured cDNA onto flow cells. Such amounts are not always attainable from samples having a relatively low DNA or RNA input; or those for which a limited number of PCR amplification cycles is preferred (less PCR bias and/or more even coverage). A well-tested sub-nanomolar library preparation protocol for Illumina sequencers has however not been reported. The aim of this study is to provide a much needed working protocol for sub-nanomolar libraries to achieve outcomes as informative as those obtained with the higher library input (≥ 2 nM) recommended by Illumina's protocols. Extensive studies were conducted to validate a robust sub-nanomolar (initial library of 100 pM) protocol using PhiX DNA (as a control), genomic DNA (Bordetella bronchiseptica and microbial mock community B for 16S rRNA gene sequencing), messenger RNA, microRNA, and other small noncoding RNA samples. The utility of our protocol was further explored for PhiX library concentrations as low as 25 pM, which generated only slightly fewer than 50% of the reads achieved under the standard Illumina protocol starting with > 2 nM. A sub-nanomolar library preparation protocol (100 pM) could generate next generation sequencing (NGS) results as robust as the standard Illumina protocol. Following the sub-nanomolar protocol, libraries with initial concentrations as low as 25 pM could also be sequenced to yield satisfactory and reproducible sequencing results.
Barik, Mayadhar; Bajpai, Minu; Patnaik, Santosh; Mishra, Pravash; Behera, Priyamadhaba; Dwivedi, Sada Nanda
2016-01-01
Cryopreservation is basically related to meritorious thin samples or small clumps of cells that are cooled quickly without loss. Our main objective is to establish and formulate an innovative method and protocol development for cryopreservation as a gold standard for clinical uses in laboratory practice and treatment. The knowledge regarding usefulness of cryopreservation in clinical practice is essential to carry forward the clinical practice and research. We are trying to compare different methods of cryopreservation (in two dozen of cells) at the same time we compare the embryo and oocyte freezing interms of fertilization rate according to the International standard protocol. The combination of cryoprotectants and regimes of rapid cooling and rinsing during warming often allows successful cryopreservation of biological materials, particularly cell suspensions or thin tissue samples. Examples include semen, blood, tissue samples like tumors, histological cross-sections, human eggs and human embryos. Although presently many studies have reported that the children born from frozen embryos or "frosties," show consistently positive results with no increase in birth defects or development abnormalities is quite good enough and similar to our study (50-85%). We ensure that cryopreservation technology provided useful cell survivability, tissue and organ preservation in a proper way. Although it varies according to different laboratory conditions, it is certainly beneficial for patient's treatment and research. Further studies are needed for standardization and development of new protocol.
A Standardized Shift Handover Protocol: Improving Nurses’ Safe Practice in Intensive Care Units
Malekzadeh, Javad; Mazluom, Seyed Reza; Etezadi, Toktam; Tasseri, Alireza
2013-01-01
Introduction: For maintaining the continuity of care and improving the quality of care, effective inter-shift information communication is necessary. Any handover error can endanger patient safety. Despite the importance of shift handover, there is no standard handover protocol in our healthcare settings. Methods: In this one-group pretest-posttest quasi-experimental study conducted in spring and summer of 2011, we recruited a convenience sample of 56 ICU nurses. The Nurses’ Safe Practice Evaluation Checklist was used for data collection. The Content Validity Index and the inter-rater correlation coefficient of the checklist was 0.92 and 89, respectively. We employed the SPSS 11.5 software and the Mc Nemar and paired-samples t test for data analysis. Results: Study findings revealed that nurses’ mean score on the Safe Practice Evaluation Checklist increased significantly from 11.6 (2.7) to 17.0 (1.8) (P < 0.001). Conclusion: using a standard handover protocol for communicating patient’s needs and information improves nurses’ safe practice in the area of basic nursing care. PMID:25276725
New Cost-Effective Method for Long-Term Groundwater Monitoring Programs
2013-05-01
with a small-volume, gas -tight syringe (< 1 mL) and injected directly into the field-portable GC. Alternatively, the well headspace sample can be...according to manufacturers’ protocols. Isobutylene was used as the calibration standard for the PID. The standard gas mixtures were used for 3-point...monitoring wells are being evaluated: 1) direct headspace sampling, 2) sampling tube with gas permeable membrane, and 3) gas -filled passive vapor
Experimental control in software reliability certification
NASA Technical Reports Server (NTRS)
Trammell, Carmen J.; Poore, Jesse H.
1994-01-01
There is growing interest in software 'certification', i.e., confirmation that software has performed satisfactorily under a defined certification protocol. Regulatory agencies, customers, and prospective reusers all want assurance that a defined product standard has been met. In other industries, products are typically certified under protocols in which random samples of the product are drawn, tests characteristic of operational use are applied, analytical or statistical inferences are made, and products meeting a standard are 'certified' as fit for use. A warranty statement is often issued upon satisfactory completion of a certification protocol. This paper outlines specific engineering practices that must be used to preserve the validity of the statistical certification testing protocol. The assumptions associated with a statistical experiment are given, and their implications for statistical testing of software are described.
Cashman, Kevin D; Kiely, Mairead; Kinsella, Michael; Durazo-Arvizu, Ramón A; Tian, Lu; Zhang, Yue; Lucey, Alice; Flynn, Albert; Gibney, Michael J; Vesper, Hubert W; Phinney, Karen W; Coates, Paul M; Picciano, Mary F; Sempos, Christopher T
2013-01-01
Background: The Vitamin D Standardization Program (VDSP) has developed protocols for standardizing procedures of 25-hydroxyvitamin D [25(OH)D] measurement in National Health/Nutrition Surveys to promote 25(OH)D measurements that are accurate and comparable over time, location, and laboratory procedure to improve public health practice. Objective: We applied VDSP protocols to existing ELISA-derived serum 25(OH)D data from the Irish National Adult Nutrition Survey (NANS) as a case-study survey and evaluated their effectiveness by comparison of the protocol-projected estimates with those from a reanalysis of survey serums by using liquid chromatography–tandem mass spectrometry (LC–tandem MS). Design: The VDSP reference system and protocols were applied to ELISA-based serum 25(OH)D data from the representative NANS sample (n = 1118). A reanalysis of 99 stored serums by using standardized LC–tandem MS and resulting regression equations yielded predicted standardized serum 25(OH)D values, which were then compared with LC–tandem MS reanalyzed values for all serums. Results: Year-round prevalence rates for serum 25(OH)D concentrations <30, <40, and <50 nmol/L were 6.5%, 21.9%, and 40.0%, respectively, via original ELISA measurements and 11.4%, 25.3%, and 43.7%, respectively, when VDSP protocols were applied. Differences in estimates at <30- and <40-nmol/L thresholds, but not at the <50-nmol/L threshold, were significant (P < 0.05). A reanalysis of all serums by using LC–tandem MS confirmed prevalence estimates as 11.2%, 27.2%, and 45.0%, respectively. Prevalences of serum 25(OH)D concentrations >125 nmol/L were 1.2%, 0.3%, and 0.6% by means of ELISA, VDSP protocols, and LC–tandem MS, respectively. Conclusion: VDSP protocols hold a major potential for national nutrition and health surveys in terms of the standardization of serum 25(OH)D data. PMID:23615829
Avberšek, Miha; Žegura, Bojana; Filipič, Metka; Heath, Ester
2011-11-01
There are many published studies that use either chemical or biological methods to investigate steroid estrogens in the aquatic environment, but rarer are those that combine both. In this study, gas chromatography with mass selective detection (GC-MSD) and the ER-Calux(®) estrogenicity assay were integrated into a single protocol for simultaneous determination of natural (estrone--E1, 17β-estradiol--E2, estriol--E3) and synthetic (17α-ethinylestradiol--EE2) steroid estrogens concentrations and the total estrogenic potential of environmental samples. For integration purposes, several solvents were investigated and the commonly used dimethyl sulphoxide (DMSO) in the ER-Calux(®) assay was replaced by ethyl acetate, which is more compatible with gas chromatography and enables the same sample to be analysed by both GC-MSD and the ER-Calux(®) assay. The integrated protocol was initially tested using a standard mixture of estrogens. The results for pure standards showed that the estrogenicity calculated on the basis of GC-MSD and the ER-Calux(®) assay exhibited good correlation (r(2)=0.96; α=0.94). The result remained the same when spiked waste water extracts were tested (r(2)=0.92, α=1.02). When applied to real waste water influent and effluent samples the results proved (r(2)=0.93; α=0.99) the applicability of the protocol. The main advantages of this newly developed protocol are simple sample handling for both methods, and reduced material consumption and labour. In addition, it can be applied as either a complete or sequential analysis where the ER-Calux(®) assay is used as a pre-screening method prior to the chemical analysis. Copyright © 2011 Elsevier B.V. All rights reserved.
A fast and mild decellularization protocol for obtaining extracellular matrix.
Mirzarafie, Ariana; Grainger, Rhian K; Thomas, Ben; Bains, William; Ustok, Fatma I; Lowe, Chris R
2014-04-01
Degradation of extracellular matrix (ECM) function with age is a major cause of loss of tissue function with age that we would wish to reverse. Tissue engineering to provide replacement tissue requires an ECM-mimicking scaffold for cell organization. The standard protocols for achieving this take 10 days and include steps that may change the protein structure of the ECM. Here we describe a much shorter protocol for decellularizing chicken muscle, skin, and tendon samples that achieves the same efficiency as the original protocol without protein cross-link interference. Our protocol can be completed in 72 hr.
21 CFR 660.36 - Samples and protocols.
Code of Federal Regulations, 2010 CFR
2010-04-01
... ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.36 Samples... a cell panel intended for identification of unexpected antibodies. The sample shall be packaged as... distribution of each lot of Reagent Red Blood Cells for detection or identification of unexpected antibodies...
A standard sampling protocol to assess the fish assemblages and abundances in large, coldwater rivers is most accurate and precise if consistent gears and levels of effort are used at each site. This requires thorough crew training, quality control audits, and replicate sampling...
This procedure summarizes the sample shipping procedures that have been described in the individual NHEXAS sample collection protocols. This procedure serves as a quick reference tool for the field staff when samples are prepared for shipment at the field lab/staging area. For ea...
2013-09-01
sequence dataset. All procedures were performed by personnel in the IIMT UT Southwestern Genomics and Microarray Core using standard protocols. More... sequencing run, samples were demultiplexed using standard algorithms in the Genomics and Microarray Core and processed into individual sample Illumina single... Sequencing (RNA-Seq), using Illumina’s multiplexing mRNA-Seq to generate full sequence libraries from the poly-A tailed RNA to a read depth of 30
Hysterectomy for placenta accreta; methods for gross and microscopic pathology examination.
Dannheim, Katelyn; Shainker, Scott A; Hecht, Jonathan L
2016-05-01
Placenta accreta is an abnormal adherence of the placenta to the uterine wall. As the incidence of placenta accreta continues to rise, it has been useful to develop standard protocols for the diagnosis and management of affected patients. Pathologists have the opportunity to take an active role in evaluating these resource intensive protocols. We describe methods of gross dissection, microscopic examination and reporting of hysterectomy specimens containing placenta accreta. This protocol facilitates retrospective correlation with surgical and radiographic findings as well as standardized tissue sampling for potential research. Through regular review of such quality measures pathologists can give feedback on the quality of surgical planning and use of imaging.
Tolerance - One Transplant for Life
Kawai, Tatsuo; Leventhal, Joseph; Madsen, Joren C.; Strober, Samuel; Turka, Laurence A.; Wood, Kathryn J.
2014-01-01
A recent TTS workshop was convened to address the question: “What do we need to have in place to make tolerance induction protocols a “standard of care” for organ transplant recipients over the next decade?” In a productive two day meeting there was wide-ranging discussion on a broad series of topics resulting in five consensus recommendations: (1) Establish a registry of results for patients enrolled in tolerance trials; (2) Establish standardized protocols for sample collection and storage; (3) Establish standardized biomarkers and assays; (4) Include children aged 12 and older in protocols that have been validated in adults; (5) a task force to engage third party payers in discussions of how to fund tolerance trials. Future planned workshops will focus on progress in implementing these recommendations and identifying other steps that the community needs to take. PMID:24926829
Chapter A10. Lakes and reservoirs: Guidelines for study design and sampling
Green, William R.; Robertson, Dale M.; Wilde, Franceska D.
2015-09-29
Within this chapter are references to other chapters of the NFM that provide more detailed guidelines related to specific topics and more detailed protocols for the quality assurance and assessment of the lake and reservoir data. Protocols and procedures to address and document the quality of lake and reservoir investigations are adapted from, or referenced to, the protocols and standard operating procedures contained in related chapters of this National Field Manual.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Flewett, S.; Saintenoy, T.; Sepulveda, M.
Archeological ceramic paste material typically consists of a mix of a clay matrix and various millimeter and sub-millimeter sized mineral inclusions. Micro X-ray Fluorescence (μXRF) is a standard compositional classification tool, and in this work we propose and demonstrate an improved fluorescence map processing protocol where the mineral inclusions are automatically separated from the clay matrix to allow independent statistical analysis of the two parts. Application of this protocol allowed us to improve enhance the differentiation discrimination between different ceramic shards compared with the standard procedure of comparing working with only the spatially averaged elemental concentrations. Using the new protocol,more » we performed an initial compositional classification of a set of 83 ceramic shards from the western slopes of the south central Andean region in the Arica y Parinacota region of present-day far northern Chile. Comparing the classifications obtained using the new versus the old (average concentrations only) protocols, we found that some samples were erroneously classified with the old protocol. From an archaeological perspective, a very broad and heterogeneous sample set was used in this study due to the fact that this was the first such study to be performed on ceramics from this region. This allowed a general overview to be obtained, however further work on more specific sample sets will be necessary to extract concrete archaeological conclusions.« less
Barik, Mayadhar; Bajpai, Minu; Patnaik, Santosh; Mishra, Pravash; Behera, Priyamadhaba; Dwivedi, Sada Nanda
2016-01-01
Background: Cryopreservation is basically related to meritorious thin samples or small clumps of cells that are cooled quickly without loss. Our main objective is to establish and formulate an innovative method and protocol development for cryopreservation as a gold standard for clinical uses in laboratory practice and treatment. The knowledge regarding usefulness of cryopreservation in clinical practice is essential to carry forward the clinical practice and research. Materials and Methods: We are trying to compare different methods of cryopreservation (in two dozen of cells) at the same time we compare the embryo and oocyte freezing interms of fertilization rate according to the International standard protocol. Results: The combination of cryoprotectants and regimes of rapid cooling and rinsing during warming often allows successful cryopreservation of biological materials, particularly cell suspensions or thin tissue samples. Examples include semen, blood, tissue samples like tumors, histological cross-sections, human eggs and human embryos. Although presently many studies have reported that the children born from frozen embryos or “frosties,” show consistently positive results with no increase in birth defects or development abnormalities is quite good enough and similar to our study (50–85%). Conclusions: We ensure that cryopreservation technology provided useful cell survivability, tissue and organ preservation in a proper way. Although it varies according to different laboratory conditions, it is certainly beneficial for patient's treatment and research. Further studies are needed for standardization and development of new protocol. PMID:27512686
The purpose of this SOP is to describe the standard approach used for cleaning glassware and plasticware during the Arizona NHEXAS project and the "Border" study. Keywords: lab; equipment; cleaning.
The National Human Exposure Assessment Survey (NHEXAS) is a federal interagency...
Standards of care provided by early pregnancy assessment units (EPAU): a UK-wide survey.
Poddar, A; Tyagi, J; Hawkins, E; Opemuyi, I
2011-10-01
Standards of services provided by the EPAUs across the UK vary from one unit to another. The aim of this purposive sampling self-administered survey was to assess these standards against a benchmark set by the Royal College of Obstetricians and Gynaecologists (RCOG). These standards were set out in a report by a RCOG working party (2008). Out of 181 units contacted in this survey, 140 units responded. We looked at the setup of the EPAU, services offered, accessibility and protocols for management of miscarriage and ectopic pregnancy. The survey shows that there is a considerable variation in the management protocols and the quality of services offered by the EPAUs in the UK. Many units do not meet the standards set by the RCOG.
Quality assured measurements of animal building emissions: odor concentrations.
Jacobson, Larry D; Hetchler, Brian P; Schmidt, David R; Nicolai, Richard E; Heber, Albert J; Ni, Ji-Qin; Hoff, Steven J; Koziel, Jacek A; Zhang, Yuanhui; Beasley, David B; Parker, David B
2008-06-01
Standard protocols for sampling and measuring odor emissions from livestock buildings are needed to guide scientists, consultants, regulators, and policy-makers. A federally funded, multistate project has conducted field studies in six states to measure emissions of odor, coarse particulate matter (PM(10)), total suspended particulates, hydrogen sulfide, ammonia, and carbon dioxide from swine and poultry production buildings. The focus of this paper is on the intermittent measurement of odor concentrations at nearly identical pairs of buildings in each state and on protocols to minimize variations in these measurements. Air was collected from pig and poultry barns in small (10 L) Tedlar bags through a gas sampling system located in an instrument trailer housing gas and dust analyzers. The samples were analyzed within 30 hr by a dynamic dilution forced-choice olfactometer (a dilution apparatus). The olfactometers (AC'SCENT International Olfactometer, St. Croix Sensory, Inc.) used by all participating laboratories meet the olfactometry standards (American Society for Testing and Materials and European Committee for Standardization [CEN]) in the United States and Europe. Trained panelists (four to eight) at each laboratory measured odor concentrations (dilution to thresholds [DT]) from the bag samples. Odor emissions were calculated by multiplying odor concentration differences between inlet and outlet air by standardized (20 degrees C and 1 atm) building airflow rates.
Protocol for monitoring metals in Ozark National Scenic Riverways, Missouri: Version 1.0
Schmitt, Christopher J.; Brumbaugh, William G.; Besser, John M.; Hinck, Jo Ellen; Bowles, David E.; Morrison, Lloyd W.; Williams, Michael H.
2008-01-01
The National Park Service is developing a monitoring plan for the Ozark National Scenic Riverways in southeastern Missouri. Because of concerns about the release of lead, zinc, and other metals from lead-zinc mining to streams, the monitoring plan will include mining-related metals. After considering a variety of alternatives, the plan will consist of measuring the concentrations of cadmium, cobalt, lead, nickel, and zinc in composite samples of crayfish (Orconectes luteus or alternate species) and Asian clam (Corbicula fluminea) collected periodically from selected sites. This document, which comprises a protocol narrative and supporting standard operating procedures, describes the methods to be employed prior to, during, and after collection of the organisms, along with procedures for their chemical analysis and quality assurance; statistical analysis, interpretation, and reporting of the data; and for modifying the protocol narrative and supporting standard operating procedures. A list of supplies and equipment, data forms, and sample labels are also included. An example based on data from a pilot study is presented.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhou, Jianying; Dann, Geoffrey P.; Shi, Tujin
2012-03-10
Sodium dodecyl sulfate (SDS) is one of the most popular laboratory reagents used for highly efficient biological sample extraction; however, SDS presents a significant challenge to LC-MS-based proteomic analyses due to its severe interference with reversed-phase LC separations and electrospray ionization interfaces. This study reports a simple SDS-assisted proteomic sample preparation method facilitated by a novel peptide-level SDS removal protocol. After SDS-assisted protein extraction and digestion, SDS was effectively (>99.9%) removed from peptides through ion substitution-mediated DS- precipitation with potassium chloride (KCl) followed by {approx}10 min centrifugation. Excellent peptide recovery (>95%) was observed for less than 20 {mu}g of peptides.more » Further experiments demonstrated the compatibility of this protocol with LC-MS/MS analyses. The resulting proteome coverage from this SDS-assisted protocol was comparable to or better than those obtained from other standard proteomic preparation methods in both mammalian tissues and bacterial samples. These results suggest that this SDS-assisted protocol is a practical, simple, and broadly applicable proteomic sample processing method, which can be particularly useful when dealing with samples difficult to solubilize by other methods.« less
21 CFR 660.36 - Samples and protocols.
Code of Federal Regulations, 2014 CFR
2014-04-01
..., whenever a new donor is used, a sample of red blood cells from each new donor used in a cell panel intended... ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.36 Samples... distribution of each lot of Reagent Red Blood Cells for detection or identification of unexpected antibodies...
21 CFR 660.36 - Samples and protocols.
Code of Federal Regulations, 2013 CFR
2013-04-01
..., whenever a new donor is used, a sample of red blood cells from each new donor used in a cell panel intended... ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.36 Samples... distribution of each lot of Reagent Red Blood Cells for detection or identification of unexpected antibodies...
21 CFR 660.36 - Samples and protocols.
Code of Federal Regulations, 2012 CFR
2012-04-01
..., whenever a new donor is used, a sample of red blood cells from each new donor used in a cell panel intended... ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.36 Samples... distribution of each lot of Reagent Red Blood Cells for detection or identification of unexpected antibodies...
A MORE COST-EFFECTIVE EMAP-W BENTHIC MACROFAUNAL SAMPLE UNIT
The standard EPA West Coast Environmental Monitoring and Assessment Program (EMAP-W) benthic macrofaunal sampling protocol is to collect 30-50 random benthic samples per reporting unit (e.g., estuary, region) using a 0.1 m2 grab and to sort out macrofauna using a 1.0 mm mesh scre...
Farage, Miranda A; Meyer, Sandy; Walter, Dave
2004-05-01
The first main objective of the work presented in this paper was to investigate ways of optimizing the current arm patch test protocol by (1) increasing the sensitivity of the test in order to evaluate more effectively the products that are inherently non-irritating, and/or (2) reducing the costs of these types of studies by shortening the protocol. The second main objective was to use the results of these studies and the results of the parallel studies conducted using the behind-the-knee method to better understand the contribution of mechanical irritation to the skin effects produced by these types of products. In addition, we were interested in continuing the evaluation of sensory effects and their relationship to objective measures of irritation. Test materials were prepared from three, currently marketed feminine protection pads. Wet and dry samples were applied to the upper arm using the standard 24-h patch test. Applications were repeated daily for 4 consecutive days. The test sites were scored for irritation prior to the first patch application, and 30-60 min after removal of each patch. Some test sites were treated by tape stripping the skin prior to the initial patch application. In addition, in one experiment, panelists were asked to keep a daily diary describing any sensory skin effects they noticed at each test site. All protocol variations ([intact skin/dry samples], [compromised skin/dry samples], [intact skin/wet samples], and [compromised skin/wet samples]) gave similar results for the products tested. When compared to the behind-the-knee test method, the standard upper arm patch test gave consistently lower levels of irritation when the test sites were scored shortly after patch removal, even though the sample application was longer (24 vs. 6 h) in the standard patch test. The higher level of irritation in the behind-the-knee method was likely due to mechanical irritation. The sensory skin effects did not appear to be related to a particular test product or a particular protocol variation. However, the mean irritation scores at those sites where a sensory effect was reported were higher than the mean irritation scores at those sites were no sensory effects were reported. All four protocol variations of the standard upper arm patch test can be used to assess the inherent chemical irritant properties of feminine protection products. For these products, which are inherently non-irritating, tape stripping and/or applying wet samples does not increase the sensitivity of the patch test method. Differences in irritation potential were apparent after one to three 24-h applications. Therefore, the standard patch test protocol can be shortened to three applications without compromising our ability to detect differences in the chemical irritation produced by the test materials. The patch test can be used to evaluate effectively the inherent chemical irritation potential of these types of products. However, this method is not suitable for testing the mechanical irritation due to friction that occurs during product use. There is no relationship between specific test conditions, i.e., compromised skin and/or testing wet samples and reports of perceived sensory reactions. However, there seems to be a clear relationship between sensory reactions and objective irritation scores.
A Data Scheduling and Management Infrastructure for the TEAM Network
NASA Astrophysics Data System (ADS)
Andelman, S.; Baru, C.; Chandra, S.; Fegraus, E.; Lin, K.; Unwin, R.
2009-04-01
The objective of the Tropical Ecology Assessment and Monitoring Network (www.teamnetwork.org) is "To generate real time data for monitoring long-term trends in tropical biodiversity through a global network of TEAM sites (i.e. field stations in tropical forests), providing an early warning system on the status of biodiversity to effectively guide conservation action". To achieve this, the TEAM Network operates by collecting data via standardized protocols at TEAM Sites. The standardized TEAM protocols include the Climate, Vegetation and Terrestrial Vertebrate Protocols. Some sites also implement additional protocols. There are currently 7 TEAM Sites with plans to grow the network to 15 by June 30, 2009 and 50 TEAM Sites by the end of 2010. Climate Protocol The Climate Protocol entails the collection of climate data via meteorological stations located at the TEAM Sites. This includes information such as precipitation, temperature, wind direction and strength and various solar radiation measurements. Vegetation Protocol The Vegetation Protocol collects standardized information on tropical forest trees and lianas. A TEAM Site will have between 6-9 1ha plots where trees and lianas larger than a pre-specified size are mapped, identified and measured. This results in each TEAM Site repeatedly measuring between 3000-5000 trees annually. Terrestrial Vertebrate Protocol The Terrestrial Vertebrate Protocol collects standardized information on mid-sized tropical forest fauna (i.e. birds and mammals). This information is collected via camera traps (i.e. digital cameras with motion sensors housed in weather proof casings). The images taken by the camera trap are reviewed to identify what species are captured in the image by the camera trap. The image and the interpretation of what is in the image are the data for the Terrestrial Vertebrate Protocol. The amount of data collected through the TEAM protocols provides a significant yet exciting IT challenge. The TEAM Network is currently partnering with the San Diego Super Computer Center to build the data management infrastructure. Data collected from the three core protocols as well as others are currently made available through the TEAM Network portal, which provides the content management framework, the data scheduling and management framework, an administrative framework to implement and manage TEAM sites, collaborative tools and a number of tools and applications utilizing Google Map and Google Earth products. A critical element of the TEAM Network data management infrastructure is to make the data publicly available in as close to real-time as possible (the TEAM Network Data Use Policy: http://www.teamnetwork.org/en/data/policy). This requires two essential tasks to be accomplished, 1) A data collection schedule has to be planned, proposed and approved for a given TEAM site. This is a challenging process since TEAM sites are geographically distributed across the tropics and hence have different seasons where they schedule field sampling for the different TEAM protocols. Capturing this information and ensuring that TEAM sites follow the outlined legal contract is key to the data collection process and 2) A stream-lined and efficient information management system to ensure data collected from the field meet the minimum data standards (i.e. are of the highest scientific quality) and are securely transferred, archived, processed and be rapidly made publicaly available, as a finished consumable product via the TEAM Network portal. The TEAM Network is achieving these goals by implementing an end-to-end framework consisting of the Sampling Scheduler application and the Data Management Framework. Sampling Scheduler The Sampling Scheduler is a project management, calendar based portal application that will allow scientists at a TEAM site to schedule field sampling for each of the TEAM protocols implemented at that site. The sampling scheduler addresses the specific requirements established in the TEAM protocols with the logistical scheduling needs of each TEAM Site. For example, each TEAM protocol defines when data must be collected (e.g. time of day, number of times per year, during which seasons, etc) as well as where data must be collected (from which sampling units, which trees, etc). Each TEAM Site has a limited number of resources and must create plans that will both satisfy the requirements of the protocols as well as be logistically feasible for their TEAM Site. With 15 TEAM Sites (and many more coming soon) the schedules of each TEAM Site must be communicated to the Network Office to ensure data are being collected as scheduled and to address the many problems when working in difficult environments like Tropical Forests. The Sampling Schedule provides built-in proposal and approval functionality to ensure that the TEAM Sites are and the Network office are in sync as well as provides the capability to modify schedules when needed. The Data Management Framework The Data Management framework is a three-tier data ingestion, edit and review application for protocols defined in the TEAM network. The data ingestion framework provides online web forms for field personnel to submit and edit data collected at TEAM Sites. These web forms will be accessible from the TEAM content management site. Once the data is securely uploaded, cured, processed and approved, it will be made publicly available for consumption by the scientific community. The Data Management framework, when combined with the Sampling Scheduler provides a closed loop Data Scheduling and Management infrastructure. All information starting from data collection plan, tools to input, modify and curate data, review and run QA/QC tests, as well as verify data are collected as planed are included. Finally, TEAM Network data are available for download via the Data Query and Download Application. This application utilizes a Google Maps custom interface to search, visualize, and download TEAM Network data. References • TEAM Network, http://www.teamnetwork.org • Center for Applied Biodiversity Science, Conservation International. http://science.conservation.org/portal/server.pt • TEAM Data Query and Download Application, http://www.teamnetwork.org/en/data/query
This protocol describes the procedures for the collection, storage, and shipping of human scalp hair samples for trace metals and arsenic or potential adduct analysis. Scalp hair samples were collected from each participant that agreed to provide the sample. Thinning shears were ...
Schukken, Y H; Rauch, B J; Morelli, J
2013-04-01
The objective of this paper was to define standardized protocols for determining the efficacy of a postmilking teat disinfectant following experimental exposure of teats to both Staphylococcus aureus and Streptococcus agalactiae. The standardized protocols describe the selection of cows and herds and define the critical points in performing experimental exposure, performing bacterial culture, evaluating the culture results, and finally performing statistical analyses and reporting of the results. The protocols define both negative control and positive control trials. For negative control trials, the protocol states that an efficacy of reducing new intramammary infections (IMI) of at least 40% is required for a teat disinfectant to be considered effective. For positive control trials, noninferiority to a control disinfectant with a published efficacy of reducing new IMI of at least 70% is required. Sample sizes for both negative and positive control trials are calculated. Positive control trials are expected to require a large trial size. Statistical analysis methods are defined and, in the proposed methods, the rate of IMI may be analyzed using generalized linear mixed models. The efficacy of the test product can be evaluated while controlling for important covariates and confounders in the trial. Finally, standards for reporting are defined and reporting considerations are discussed. The use of the defined protocol is shown through presentation of the results of a recent trial of a test product against a negative control. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
The purpose of this SOP is to describe the standard approach used for cleaning glassware and plasticware during the Arizona NHEXAS project and the Border study. Keywords: lab; equipment; cleaning.
The U.S.-Mexico Border Program is sponsored by the Environmental Health Workgroup...
Lewandowska, Dagmara W; Zagordi, Osvaldo; Geissberger, Fabienne-Desirée; Kufner, Verena; Schmutz, Stefan; Böni, Jürg; Metzner, Karin J; Trkola, Alexandra; Huber, Michael
2017-08-08
Sequence-specific PCR is the most common approach for virus identification in diagnostic laboratories. However, as specific PCR only detects pre-defined targets, novel virus strains or viruses not included in routine test panels will be missed. Recently, advances in high-throughput sequencing allow for virus-sequence-independent identification of entire virus populations in clinical samples, yet standardized protocols are needed to allow broad application in clinical diagnostics. Here, we describe a comprehensive sample preparation protocol for high-throughput metagenomic virus sequencing using random amplification of total nucleic acids from clinical samples. In order to optimize metagenomic sequencing for application in virus diagnostics, we tested different enrichment and amplification procedures on plasma samples spiked with RNA and DNA viruses. A protocol including filtration, nuclease digestion, and random amplification of RNA and DNA in separate reactions provided the best results, allowing reliable recovery of viral genomes and a good correlation of the relative number of sequencing reads with the virus input. We further validated our method by sequencing a multiplexed viral pathogen reagent containing a range of human viruses from different virus families. Our method proved successful in detecting the majority of the included viruses with high read numbers and compared well to other protocols in the field validated against the same reference reagent. Our sequencing protocol does work not only with plasma but also with other clinical samples such as urine and throat swabs. The workflow for virus metagenomic sequencing that we established proved successful in detecting a variety of viruses in different clinical samples. Our protocol supplements existing virus-specific detection strategies providing opportunities to identify atypical and novel viruses commonly not accounted for in routine diagnostic panels.
National protocol framework for the inventory and monitoring of bees
Droege, Sam; Engler, Joseph D.; Sellers, Elizabeth A.; Lee O'Brien,
2016-01-01
This national protocol framework is a standardized tool for the inventory and monitoring of the approximately 4,200 species of native and non-native bee species that may be found within the National Wildlife Refuge System (NWRS) administered by the U.S. Fish and Wildlife Service (USFWS). However, this protocol framework may also be used by other organizations and individuals to monitor bees in any given habitat or location. Our goal is to provide USFWS stations within the NWRS (NWRS stations are land units managed by the USFWS such as national wildlife refuges, national fish hatcheries, wetland management districts, conservation areas, leased lands, etc.) with techniques for developing an initial baseline inventory of what bee species are present on their lands and to provide an inexpensive, simple technique for monitoring bees continuously and for monitoring and evaluating long-term population trends and management impacts. The latter long-term monitoring technique requires a minimal time burden for the individual station, yet can provide a good statistical sample of changing populations that can be investigated at the station, regional, and national levels within the USFWS’ jurisdiction, and compared to other sites within the United States and Canada. This protocol framework was developed in cooperation with the United States Geological Survey (USGS), the USFWS, and a worldwide network of bee researchers who have investigated the techniques and methods for capturing bees and tracking population changes. The protocol framework evolved from field and lab-based investigations at the USGS Bee Inventory and Monitoring Laboratory at the Patuxent Wildlife Research Center in Beltsville, Maryland starting in 2002 and was refined by a large number of USFWS, academic, and state groups. It includes a Protocol Introduction and a set of 8 Standard Operating Procedures or SOPs and adheres to national standards of protocol content and organization. The Protocol Narrative describes the history and need for the protocol framework and summarizes the basic elements of objectives, sampling design, field methods, training, data management, analysis, and reporting. The SOPs provide more detail and specific instructions for implementing the protocol framework. A central database, for managing all the resulting data is under development. We welcome use of this protocol framework by our partners, as appropriate for their bee inventory and monitoring objectives.
This protocol describes the procedures for weighing, handling, and archiving aerosol filters and for managing the associated analytical and quality assurance data. Filter samples were weighed for aerosol mass at RTI laboratory, with only the automated field sampling data transfer...
Mobile/Modular BSL-4 Facilities for Meeting Restricted Earth Return Containment Requirements
NASA Technical Reports Server (NTRS)
Calaway, M. J.; McCubbin, F. M.; Allton, J. H.; Zeigler, R. A.; Pace, L. F.
2017-01-01
NASA robotic sample return missions designated Category V Restricted Earth Return by the NASA Planetary Protection Office require sample containment and biohazard testing in a receiving laboratory as directed by NASA Procedural Requirement (NPR) 8020.12D - ensuring the preservation and protection of Earth and the sample. Currently, NPR 8020.12D classifies Restricted Earth Return for robotic sample return missions from Mars, Europa, and Enceladus with the caveat that future proposed mission locations could be added or restrictions lifted on a case by case basis as scientific knowledge and understanding of biohazards progresses. Since the 1960s, sample containment from an unknown extraterrestrial biohazard have been related to the highest containment standards and protocols known to modern science. Today, Biosafety Level (BSL) 4 standards and protocols are used to study the most dangerous high-risk diseases and unknown biological agents on Earth. Over 30 BSL-4 facilities have been constructed worldwide with 12 residing in the United States; of theses, 8 are operational. In the last two decades, these brick and mortar facilities have cost in the hundreds of millions of dollars dependent on the facility requirements and size. Previous mission concept studies for constructing a NASA sample receiving facility with an integrated BSL-4 quarantine and biohazard testing facility have also been estimated in the hundreds of millions of dollars. As an alternative option, we have recently conducted an initial trade study for constructing a mobile and/or modular sample containment laboratory that would meet all BSL-4 and planetary protection standards and protocols at a faction of the cost. Mobile and modular BSL-2 and 3 facilities have been successfully constructed and deployed world-wide for government testing of pathogens and pharmaceutical production. Our study showed that a modular BSL-4 construction could result in approximately 90% cost reduction when compared to traditional construction methods without compromising the preservation of the sample or Earth.
A new real-time PCR protocol for detection of avian haemosporidians.
Bell, Jeffrey A; Weckstein, Jason D; Fecchio, Alan; Tkach, Vasyl V
2015-07-19
Birds possess the most diverse assemblage of haemosporidian parasites; including three genera, Plasmodium, Haemoproteus, and Leucocytozoon. Currently there are over 200 morphologically identified avian haemosporidian species, although true species richness is unknown due to great genetic diversity and insufficient sampling in highly diverse regions. Studies aimed at surveying haemosporidian diversity involve collecting and screening samples from hundreds to thousands of individuals. Currently, screening relies on microscopy and/or single or nested standard PCR. Although effective, these methods are time and resource consuming, and in the case of microscopy require substantial expertise. Here we report a newly developed real-time PCR protocol designed to quickly and reliably detect all three genera of avian haemosporidians in a single biochemical reaction. Using available DNA sequences from avian haemosporidians we designed primers R330F and R480RL, which flank a 182 base pair fragment of mitochondrial conserved rDNA. These primers were initially tested using real-time PCR on samples from Malawi, Africa, previously screened for avian haemosporidians using traditional nested PCR. Our real time protocol was further tested on 94 samples from the Cerrado biome of Brazil, previously screened using a single PCR assay for haemosporidian parasites. These samples were also amplified using modified nested PCR protocols, allowing for comparisons between the three different screening methods (single PCR, nested PCR, real-time PCR). The real-time PCR protocol successfully identified all three genera of avian haemosporidians from both single and mixed infections previously detected from Malawi. There was no significant difference between the three different screening protocols used for the 94 samples from the Brazilian Cerrado (χ(2) = 0.3429, df = 2, P = 0.842). After proving effective, the real-time protocol was used to screen 2113 Brazilian samples, identifying 693 positive samples. Our real-time PCR assay proved as effective as two widely used molecular screening techniques, single PCR and nested PCR. However, the real-time protocol has the distinct advantage of detecting all three genera in a single reaction, which significantly increases efficiency by greatly decreasing screening time and cost. Our real-time PCR protocol is therefore a valuable tool in the quickly expanding field of avian haemosporidian research.
Shanks, Orin C; Kelty, Catherine A; Oshiro, Robin; Haugland, Richard A; Madi, Tania; Brooks, Lauren; Field, Katharine G; Sivaganesan, Mano
2016-05-01
There is growing interest in the application of human-associated fecal source identification quantitative real-time PCR (qPCR) technologies for water quality management. The transition from a research tool to a standardized protocol requires a high degree of confidence in data quality across laboratories. Data quality is typically determined through a series of specifications that ensure good experimental practice and the absence of bias in the results due to DNA isolation and amplification interferences. However, there is currently a lack of consensus on how best to evaluate and interpret human fecal source identification qPCR experiments. This is, in part, due to the lack of standardized protocols and information on interlaboratory variability under conditions for data acceptance. The aim of this study is to provide users and reviewers with a complete series of conditions for data acceptance derived from a multiple laboratory data set using standardized procedures. To establish these benchmarks, data from HF183/BacR287 and HumM2 human-associated qPCR methods were generated across 14 laboratories. Each laboratory followed a standardized protocol utilizing the same lot of reference DNA materials, DNA isolation kits, amplification reagents, and test samples to generate comparable data. After removal of outliers, a nested analysis of variance (ANOVA) was used to establish proficiency metrics that include lab-to-lab, replicate testing within a lab, and random error for amplification inhibition and sample processing controls. Other data acceptance measurements included extraneous DNA contamination assessments (no-template and extraction blank controls) and calibration model performance (correlation coefficient, amplification efficiency, and lower limit of quantification). To demonstrate the implementation of the proposed standardized protocols and data acceptance criteria, comparable data from two additional laboratories were reviewed. The data acceptance criteria proposed in this study should help scientists, managers, reviewers, and the public evaluate the technical quality of future findings against an established benchmark. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Zhang, Weihong; Chen, Jianhan
2013-06-11
Temperature-based replica exchange (RE) is now considered a principal technique for enhanced sampling of protein conformations. It is also recognized that existence of sharp cooperative transitions (such as protein folding/unfolding) can lead to temperature exchange bottlenecks and significantly reduce the sampling efficiency. Here, we revisit two adaptive temperature-based RE protocols, namely, exchange equalization (EE) and current maximization (CM), that were previously examined using atomistic simulations (Lee and Olson, J. Chem. Physics2011, 134, 24111). Both protocols aim to overcome exchange bottlenecks by adaptively adjusting the simulation temperatures, either to achieve uniform exchange rates (in EE) or to maximize temperature diffusion (CM). By designing a realistic yet computationally tractable coarse-grained protein model, one can sample many reversible folding/unfolding transitions using conventional constant temperature molecular dynamics (MD), standard REMD, EE-REMD, and CM-REMD. This allows rigorous evaluation of the sampling efficiency, by directly comparing the rates of folding/unfolding transitions and convergence of various thermodynamic properties of interest. The results demonstrate that both EE and CM can indeed enhance temperature diffusion compared to standard RE, by ∼3- and over 10-fold, respectively. Surprisingly, the rates of reversible folding/unfolding transitions are similar in all three RE protocols. The convergence rates of several key thermodynamic properties, including the folding stability and various 1D and 2D free energy surfaces, are also similar. Therefore, the efficiency of RE protocols does not appear to be limited by temperature diffusion, but by the inherent rates of spontaneous large-scale conformational rearrangements. This is particularly true considering that virtually all RE simulations of proteins in practice involve exchange attempt frequencies (∼ps(-1)) that are several orders of magnitude faster than the slowest protein motions (∼μs(-1)). Our results also suggest that the efficiency of RE will not likely be improved by other protocols that aim to accelerate exchange or temperature diffusion. Instead, protocols with some types of guided tempering will likely be necessary to drive faster large-scale conformational transitions.
Pavlekovic, Marko; Schmid, Markus C; Schmider-Poignee, Nadja; Spring, Stefan; Pilhofer, Martin; Gaul, Tobias; Fiandaca, Mark; Löffler, Frank E; Jetten, Mike; Schleifer, K-H; Lee, Natuschka M
2009-08-01
Fluorescence in situ hybridization (FISH) using fluorochrome-labeled DNA oligonucleotide probes has been successfully applied for in situ detection of anaerobic ammonium oxidizing (anammox) bacteria. However, application of the standard FISH protocols to visualize anammox bacteria in biofilms from a laboratory-scale wastewater reactor produced only weak signals. Increased signal intensity was achieved either by modifying the standard FISH protocol, using peptide nucleic acid probes (PNA FISH), or applying horse radish peroxidase- (HRP-) labeled probes and subsequent catalyzed reporter deposition (CARD-FISH). A comparative analysis using anammox biofilm samples and suspended anammox biomass from different laboratory wastewater bioreactors revealed that the modified standard FISH protocol and the PNA FISH probes produced equally strong fluorescence signals on suspended biomass, but only weak signals were obtained with the biofilm samples. The probe signal intensities in the biofilm samples could be enhanced by enzymatic pre-treatment of fixed cells, and by increasing the hybridization time of the PNA FISH protocol. CARD-FISH always produced up to four-fold stronger fluorescent signals but unspecific fluorescence signals, likely caused by endogenous peroxidases as reported in several previous studies, compromised the results. Interference of the development of fluorescence intensity with endogenous peroxidases was also observed in cells of aerobic ammonium oxidizers like Nitrosomonas europea, and sulfate-reducers like Desulfobacter postgatei. Interestingly, no interference was observed with other peroxidase-positive microorganisms, suggesting that CARD-FISH is not only compromised by the mere presence of peroxidases. Pre-treatment of cells to inactivate peroxidase with HCl or autoclavation/pasteurization failed to inactive peroxidases, but H(2)O(2) significantly reduced endogenous peroxidase activity. However, for optimal inactivation, different H(2)O(2) concentrations and incubation time may be needed, depending on nature of sample and should therefore always be individually determined for each study.
A rapid and efficient DNA extraction protocol from fresh and frozen human blood samples.
Guha, Pokhraj; Das, Avishek; Dutta, Somit; Chaudhuri, Tapas Kumar
2018-01-01
Different methods available for extraction of human genomic DNA suffer from one or more drawbacks including low yield, compromised quality, cost, time consumption, use of toxic organic solvents, and many more. Herein, we aimed to develop a method to extract DNA from 500 μL of fresh or frozen human blood. Five hundred microliters of fresh and frozen human blood samples were used for standardization of the extraction procedure. Absorbance at 260 and 280 nm, respectively, (A 260 /A 280 ) were estimated to check the quality and quantity of the extracted DNA sample. Qualitative assessment of the extracted DNA was checked by Polymerase Chain reaction and double digestion of the DNA sample. Our protocol resulted in average yield of 22±2.97 μg and 20.5±3.97 μg from 500 μL of fresh and frozen blood, respectively, which were comparable to many reference protocols and kits. Besides yielding bulk amount of DNA, our protocol is rapid, economical, and avoids toxic organic solvents such as Phenol. Due to unaffected quality, the DNA is suitable for downstream applications. The protocol may also be useful for pursuing basic molecular researches in laboratories having limited funds. © 2017 Wiley Periodicals, Inc.
Dukić, Lora; Kopčinović, Lara Milevoj; Dorotić, Adrijana; Baršić, Ivana
2016-10-15
Blood gas analysis (BGA) is exposed to risks of errors caused by improper sampling, transport and storage conditions. The Clinical and Laboratory Standards Institute (CLSI) generated documents with recommendations for avoidance of potential errors caused by sample mishandling. Two main documents related to BGA issued by the CLSI are GP43-A4 (former H11-A4) Procedures for the collection of arterial blood specimens; approved standard - fourth edition, and C46-A2 Blood gas and pH analysis and related measurements; approved guideline - second edition. Practices related to processing of blood gas samples are not standardized in the Republic of Croatia. Each institution has its own protocol for ordering, collection and analysis of blood gases. Although many laboratories use state of the art analyzers, still many preanalytical procedures remain unchanged. The objective of the Croatian Society of Medical Biochemistry and Laboratory Medicine (CSMBLM) is to standardize the procedures for BGA based on CLSI recommendations. The Working Group for Blood Gas Testing as part of the Committee for the Scientific Professional Development of the CSMBLM prepared a set of recommended protocols for sampling, transport, storage and processing of blood gas samples based on relevant CLSI documents, relevant literature search and on the results of Croatian survey study on practices and policies in acid-base testing. Recommendations are intended for laboratory professionals and all healthcare workers involved in blood gas processing.
Dukić, Lora; Kopčinović, Lara Milevoj; Dorotić, Adrijana; Baršić, Ivana
2016-01-01
Blood gas analysis (BGA) is exposed to risks of errors caused by improper sampling, transport and storage conditions. The Clinical and Laboratory Standards Institute (CLSI) generated documents with recommendations for avoidance of potential errors caused by sample mishandling. Two main documents related to BGA issued by the CLSI are GP43-A4 (former H11-A4) Procedures for the collection of arterial blood specimens; approved standard – fourth edition, and C46-A2 Blood gas and pH analysis and related measurements; approved guideline – second edition. Practices related to processing of blood gas samples are not standardized in the Republic of Croatia. Each institution has its own protocol for ordering, collection and analysis of blood gases. Although many laboratories use state of the art analyzers, still many preanalytical procedures remain unchanged. The objective of the Croatian Society of Medical Biochemistry and Laboratory Medicine (CSMBLM) is to standardize the procedures for BGA based on CLSI recommendations. The Working Group for Blood Gas Testing as part of the Committee for the Scientific Professional Development of the CSMBLM prepared a set of recommended protocols for sampling, transport, storage and processing of blood gas samples based on relevant CLSI documents, relevant literature search and on the results of Croatian survey study on practices and policies in acid-base testing. Recommendations are intended for laboratory professionals and all healthcare workers involved in blood gas processing. PMID:27812301
How well do we know the infaunal biomass of the continental shelf?
NASA Astrophysics Data System (ADS)
Powell, Eric N.; Mann, Roger
2016-03-01
Benthic infauna comprise a wide range of taxa of varying abundances and sizes, but large infaunal taxa are infrequently recorded in community surveys of the shelf benthos. These larger, but numerically rare, species may contribute disproportionately to biomass, however. We examine the degree to which standard benthic sampling gear and survey design provide an adequate estimate of the biomass of large infauna using the Atlantic surfclam, Spisula solidissima, on the continental shelf off the northeastern coast of the United States as a test organism. We develop a numerical model that simulates standard survey designs, gear types, and sampling densities to evaluate the effectiveness of vertically-dropped sampling gear (e.g., boxcores, grabs) for estimating density of large species. Simulations of randomly distributed clams at a density of 0.5-1 m-2 within an 0.25-km2 domain show that lower sampling densities (1-5 samples per sampling event) resulted in highly inaccurate estimates of clam density with the presence of clams detected in less than 25% of the sampling events. In all cases in which patchiness was present in the simulated clam population, surveys were prone to very large errors (survey availability events) unless a dense (e.g., 100-sample) sampling protocol was imposed. Thus, commercial quantities of surfclams could easily go completely undetected by any standard benthic community survey protocol using vertically-dropped gear. Without recourse to modern high-volume sampling gear capable of sampling many meters at a swath, such as hydraulic dredges, biomass of the continental shelf will be grievously underestimated if large infauna are present even at moderate densities.
Kalim, Shahid; Nazir, Shaista; Khan, Zia Ullah
2013-01-01
Protocols based on newer high sensitivity Troponin T (hsTropT) assays can rule in a suspected Acute Myocardial Infarction (AMI) as early as 3 hours. We conducted this study to audit adherence to our Trust's newly introduced AMI diagnostic protocol based on paired hsTropT testing at 0 and 3 hours. We retrospectively reviewed data of all patients who had hsTropT test done between 1st and 7th May 2012. Patient's demographics, utility of single or paired samples, time interval between paired samples, patient's presenting symptoms and ECG findings were noted and their means, medians, Standard deviations and proportions were calculated. A total of 66 patients had hsTropT test done during this period. Mean age was 63.30 +/- 17.46 years and 38 (57.57%) were males. Twenty-four (36.36%) patients had only single, rather than protocol recommended paired hsTropT samples, taken. Among the 42 (63.63%) patients with paired samples, the mean time interval was found to be 4.41 +/- 5.7 hours. Contrary to the recommendations, 15 (22.73%) had a very long whereas 2 (3.03%) had a very short time interval between two samples. A subgroup analysis of patients with single samples, found only 2 (3.03%) patient with ST-segment elevation, appropriate for single testing. Our study confirmed that in a large number of patients the protocol for paired sampling or a recommended time interval of 3 hours between 2 samples was not being followed.
EuroFlow standardization of flow cytometer instrument settings and immunophenotyping protocols
Kalina, T; Flores-Montero, J; van der Velden, V H J; Martin-Ayuso, M; Böttcher, S; Ritgen, M; Almeida, J; Lhermitte, L; Asnafi, V; Mendonça, A; de Tute, R; Cullen, M; Sedek, L; Vidriales, M B; Pérez, J J; te Marvelde, J G; Mejstrikova, E; Hrusak, O; Szczepański, T; van Dongen, J J M; Orfao, A
2012-01-01
The EU-supported EuroFlow Consortium aimed at innovation and standardization of immunophenotyping for diagnosis and classification of hematological malignancies by introducing 8-color flow cytometry with fully standardized laboratory procedures and antibody panels in order to achieve maximally comparable results among different laboratories. This required the selection of optimal combinations of compatible fluorochromes and the design and evaluation of adequate standard operating procedures (SOPs) for instrument setup, fluorescence compensation and sample preparation. Additionally, we developed software tools for the evaluation of individual antibody reagents and antibody panels. Each section describes what has been evaluated experimentally versus adopted based on existing data and experience. Multicentric evaluation demonstrated high levels of reproducibility based on strict implementation of the EuroFlow SOPs and antibody panels. Overall, the 6 years of extensive collaborative experiments and the analysis of hundreds of cell samples of patients and healthy controls in the EuroFlow centers have provided for the first time laboratory protocols and software tools for fully standardized 8-color flow cytometric immunophenotyping of normal and malignant leukocytes in bone marrow and blood; this has yielded highly comparable data sets, which can be integrated in a single database. PMID:22948490
Kulkarni, Sughosh S; Madalgi, Radhika; Ajantha, Ganavalli S; Kulkarni, Raghavendra D
2017-01-01
Acinetobacter is grouped under nonfermenting Gram-negative bacilli. It is increasingly isolated from pathological samples. The ability of this genus to acquire drug resistance and spread in the hospital settings is posing a grave problem in healthcare. Specific treatment protocols are advocated for Acinetobacter infections. Hence, rapid identification and drug susceptibility profiling are critical in the management of these infections. To standardize an in-house polymerase chain reaction (PCR) for identification of genus Acinetobacter and to compare PCR with two protocols for its phenotypic identification. A total of 96 clinical isolates of Acinetobacter were included in the study. An in-house PCR for genus level identification of Acinetobacter was standardized. All the isolates were phenotypically identified by two protocols. The results of PCR and phenotypic identification protocols were compared. The in-house PCR standardized was highly sensitive and specific for the genus Acinetobacter . There was 100% agreement between the phenotypic and molecular identification of the genus. The preliminary identification tests routinely used in clinical laboratories were also in complete agreement with phenotypic and molecular identification. The in-house PCR for genus level identification is specific and sensitive. However, it may not be essential for routine identification as the preliminary phenotypic identification tests used in the clinical laboratory reliably identify the genus Acinetobacter .
Campoy, Irene; Lanau, Lucia; Altadill, Tatiana; Sequeiros, Tamara; Cabrera, Silvia; Cubo-Abert, Montserrat; Pérez-Benavente, Assumpción; Garcia, Angel; Borrós, Salvador; Santamaria, Anna; Ponce, Jordi; Matias-Guiu, Xavier; Reventós, Jaume; Gil-Moreno, Antonio; Rigau, Marina; Colas, Eva
2016-06-18
Uterine aspirates are used in the diagnostic process of endometrial disorders, yet further applications could emerge if its complex milieu was simplified. Exosome-like vesicles isolated from uterine aspirates could become an attractive source of biomarkers, but there is a need to standardize isolation protocols. The objective of the study was to determine whether exosome-like vesicles exist in the fluid fraction of uterine aspirates and to compare protocols for their isolation, characterization, and analysis. We collected uterine aspirates from 39 pre-menopausal women suffering from benign gynecological diseases. The fluid fraction of 27 of those aspirates were pooled and split into equal volumes to evaluate three differential centrifugation-based procedures: (1) a standard protocol, (2) a filtration protocol, and (3) a sucrose cushion protocol. Characterization of isolated vesicles was assessed by electron microscopy, nanoparticle tracking analysis and immunoblot. Specifically for RNA material, we evaluate the effect of sonication and RNase A treatment at different steps of the protocol. We finally confirmed the efficiency of the selected methods in non-pooled samples. All protocols were useful to isolate exosome-like vesicles. However, the Standard procedure was the best performing protocol to isolate exosome-like vesicles from uterine aspirates: nanoparticle tracking analysis revealed a higher concentration of vesicles with a mode of 135 ± 5 nm, and immunoblot showed a higher expression of exosome-related markers (CD9, CD63, and CD81) thus verifying an enrichment in this type of vesicles. RNA contained in exosome-like vesicles was successfully extracted with no sonication treatment and exogenous nucleic acids digestion with RNaseA, allowing the analysis of the specific inner cargo by Real-Time qPCR. We confirmed the existence of exosome-like vesicles in the fluid fraction of uterine aspirates. They were successfully isolated by differential centrifugation giving sufficient proteomic and transcriptomic material for further analyses. The Standard protocol was the best performing procedure since the other two tested protocols did not ameliorate neither yield nor purity of exosome-like vesicles. This study contributes to establishing the basis for future comparative studies to foster the field of biomarker research in gynecology.
Speit, Günter; Kojima, Hajime; Burlinson, Brian; Collins, Andrew R; Kasper, Peter; Plappert-Helbig, Ulla; Uno, Yoshifumi; Vasquez, Marie; Beevers, Carol; De Boeck, Marlies; Escobar, Patricia A; Kitamoto, Sachiko; Pant, Kamala; Pfuhler, Stefan; Tanaka, Jin; Levy, Dan D
2015-05-01
As a part of the 6th IWGT, an expert working group on the comet assay evaluated critical topics related to the use of the in vivo comet assay in regulatory genotoxicity testing. The areas covered were: identification of the domain of applicability and regulatory acceptance, identification of critical parameters of the protocol and attempts to standardize the assay, experience with combination and integration with other in vivo studies, demonstration of laboratory proficiency, sensitivity and power of the protocol used, use of different tissues, freezing of samples, and choice of appropriate measures of cytotoxicity. The standard protocol detects various types of DNA lesions but it does not detect all types of DNA damage. Modifications of the standard protocol may be used to detect additional types of specific DNA damage (e.g., cross-links, bulky adducts, oxidized bases). In addition, the working group identified critical parameters that should be carefully controlled and described in detail in every published study protocol. In vivo comet assay results are more reliable if they were obtained in laboratories that have demonstrated proficiency. This includes demonstration of adequate response to vehicle controls and an adequate response to a positive control for each tissue being examined. There was a general agreement that freezing of samples is an option but more data are needed in order to establish generally accepted protocols. With regard to tissue toxicity, the working group concluded that cytotoxicity could be a confounder of comet results. It is recommended to look at multiple parameters such as histopathological observations, organ-specific clinical chemistry as well as indicators of tissue inflammation to decide whether compound-specific toxicity might influence the result. The expert working group concluded that the alkaline in vivo comet assay is a mature test for the evaluation of genotoxicity and can be recommended to regulatory agencies for use. Copyright © 2014 Elsevier B.V. All rights reserved.
Prüller, Florian; Wagner, Jasmin; Raggam, Reinhard B; Hoenigl, Martin; Kessler, Harald H; Truschnig-Wilders, Martie; Krause, Robert
2014-07-01
Testing for (1→3)-beta-D-glucan (BDG) is used for detection of invasive fungal infection. However, current assays lack automation and the ability to conduct rapid single-sample testing. The Fungitell assay was adopted for automation and evaluated using clinical samples from patients with culture-proven candidemia and from culture-negative controls in duplicate. A comparison with the standard assay protocol was made in order to establish analytical specifications. With the automated protocol, the analytical measuring range was 8-2500 pg/ml of BDG, and precision testing resulted in coefficients of variation that ranged from 3.0% to 5.5%. Samples from 15 patients with culture-proven candidemia and 94 culture-negative samples were evaluated. All culture-proven samples showed BDG values >80 pg/ml (mean 1247 pg/ml; range, 116-2990 pg/ml), which were considered positive. Of the 94 culture-negative samples, 92 had BDG values <60 pg/ml (mean, 28 pg/ml), which were considered to be negative, and 2 samples were false-positive (≥80 pg/ml; up to 124 pg/ml). Results could be obtained within 45 min and showed excellent agreement with results obtained with the standard assay protocol. The automated Fungitell assay proved to be reliable and rapid for diagnosis of candidemia. It was demonstrated to be feasible and cost efficient for both single-sample and large-scale testing of serum BDG. Its 1-h time-to-result will allow better support for clinicians in the management of antifungal therapy. © The Author 2014. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Onda, Yuichi; Kato, Hiroaki; Hoshi, Masaharu; Takahashi, Yoshio; Nguyen, Minh-Long
2015-01-01
The Fukushima Dai-ichi Nuclear Power Plant (FDNPP) accident resulted in extensive radioactive contamination of the environment via deposited radionuclides such as radiocesium and (131)I. Evaluating the extent and level of environmental contamination is critical to protecting citizens in affected areas and to planning decontamination efforts. However, a standardized soil sampling protocol is needed in such emergencies to facilitate the collection of large, tractable samples for measuring gamma-emitting radionuclides. In this study, we developed an emergency soil sampling protocol based on preliminary sampling from the FDNPP accident-affected area. We also present the results of a preliminary experiment aimed to evaluate the influence of various procedures (e.g., mixing, number of samples) on measured radioactivity. Results show that sample mixing strongly affects measured radioactivity in soil samples. Furthermore, for homogenization, shaking the plastic sample container at least 150 times or disaggregating soil by hand-rolling in a disposable plastic bag is required. Finally, we determined that five soil samples within a 3 m × 3-m area are the minimum number required for reducing measurement uncertainty in the emergency soil sampling protocol proposed here. Copyright © 2014 Elsevier Ltd. All rights reserved.
Evaluation of two types of swabs for sampling allograft musculoskeletal tissue.
Varettas, Kerry
2015-01-01
Allograft musculoskeletal tissue is commonly sampled by a swab for bioburden screening. To determine if bioburden recovery could be improved at the pre-analytical stage, two swab systems were evaluated: the Amies gel swab and the ESwab. In vitro studies were performed to determine the recovery of each swab system with <100 colony-forming unit of challenge organisms using inoculated swabs and by sampling inoculated femoral heads. The standard culture protocol used in this laboratory was also evaluated after sampling of inoculated femoral heads. A prospective study was performed with both swab systems used in parallel to sample cadaveric allograft musculoskeletal tissue. The challenge organisms could be recovered from the in vitro inoculated studies. The standard culture protocol in this laboratory recovered all challenge organisms from both swab systems. One hundred and six paired Amies and ESwabs were collected from eight cadaveric donors with skin commensals the predominant isolates. The sampling of an inoculated femoral head was included to reflect routine swab sampling practice as was the inclusion of the standard method used in this laboratory. This appears to be the first study to compare Amies gel swabs with ESwabs to sample allograft femoral heads and in a prospective study with cadaveric allograft musculoskeletal tissue. Other comparative studies of swab systems have used a much higher inoculum to mimic an infection; however, sepsis is an exclusion criterion for allograft donors. It was found that the Amies gel swab and ESwab are both suitable sampling devices for bioburden testing of allograft musculoskeletal tissue. © 2014 Royal Australasian College of Surgeons.
Coorevits, L; Heytens, S; Boelens, J; Claeys, G
2017-04-01
The workup and interpretation of urine cultures is not always clear-cut, especially for midstream samples contaminated with commensals. Standard urine culture (SUC) protocols are designed in favor of growth of uropathogens at the expense of commensals. In selected clinical situations, however, it is essential to trace fastidious or new uropathogens by expanding the urine culture conditions (EUC). The aim of our study was to map the microflora in midstream urine specimens from healthy controls by means of EUC, in view of the interpretation of bacterial culture results in symptomatic patients. Midstream urine specimens from 101 healthy controls (86 females and 15 males) were examined using both SUC and EUC. Whilst 73 % of samples examined by SUC showed no growth at 10 3 colony-forming units (CFU)/mL, 91 % of samples examined by EUC grew bacterial species in large numbers (≥10 4 CFU/mL). Asymptomatic bacteriuria, as defined by the European guidelines for urinalysis, was detected in six samples with both protocols. EUC revealed 98 different species, mostly Lactobacillus, Staphylococcus, Streptococcus, and Corynebacterium. None of the samples grew Staphylococcus saprophyticus, Corynebacterium urealyticum, or Aerococcus urinae. Samples from females contained higher bacterial loads and showed higher bacterial diversity compared to males. Midstream urine of healthy controls contains large communities of living bacteria that comprise a resident microflora, only revealed by EUC. Hence, the use of EUC instead of SUC in a routine setting would result in more sensitive but less specific results, requiring critical interpretation. In our view, EUC should be reserved for limited indications.
Spin ensemble-based AC magnetometry using concatenated dynamical decoupling at low temperatures
NASA Astrophysics Data System (ADS)
Farfurnik, D.; Jarmola, A.; Budker, D.; Bar-Gill, N.
2018-01-01
Ensembles of nitrogen-vacancy centers in diamond are widely used as AC magnetometers. While such measurements are usually performed using standard (XY) dynamical decoupling (DD) protocols at room temperature, we study the sensitivities achieved by utilizing various DD protocols, for measuring magnetic AC fields at frequencies in the 10-250 kHz range, at room temperature and 77 K. By performing measurements on an isotopically pure 12C sample, we find that the Carr-Purcell-Meiboom-Gill protocol, which is not robust against pulse imperfections, is less efficient for magnetometry than robust XY-based sequences. The concatenation of a standard XY-based protocol may enhance the sensitivities only for measuring high-frequency fields, for which many (> 500) DD pulses are necessary and the robustness against pulse imperfections is critical. Moreover, we show that cooling is effective only for measuring low-frequency fields (˜10 kHz), for which the experiment time approaches T 1 at a small number of applied DD pulses.
Mitra, Abhishek; Skrzypczak, Magdalena; Ginalski, Krzysztof; Rowicka, Maga
2015-01-01
Sequencing microRNA, reduced representation sequencing, Hi-C technology and any method requiring the use of in-house barcodes result in sequencing libraries with low initial sequence diversity. Sequencing such data on the Illumina platform typically produces low quality data due to the limitations of the Illumina cluster calling algorithm. Moreover, even in the case of diverse samples, these limitations are causing substantial inaccuracies in multiplexed sample assignment (sample bleeding). Such inaccuracies are unacceptable in clinical applications, and in some other fields (e.g. detection of rare variants). Here, we discuss how both problems with quality of low-diversity samples and sample bleeding are caused by incorrect detection of clusters on the flowcell during initial sequencing cycles. We propose simple software modifications (Long Template Protocol) that overcome this problem. We present experimental results showing that our Long Template Protocol remarkably increases data quality for low diversity samples, as compared with the standard analysis protocol; it also substantially reduces sample bleeding for all samples. For comprehensiveness, we also discuss and compare experimental results from alternative approaches to sequencing low diversity samples. First, we discuss how the low diversity problem, if caused by barcodes, can be avoided altogether at the barcode design stage. Second and third, we present modified guidelines, which are more stringent than the manufacturer’s, for mixing low diversity samples with diverse samples and lowering cluster density, which in our experience consistently produces high quality data from low diversity samples. Fourth and fifth, we present rescue strategies that can be applied when sequencing results in low quality data and when there is no more biological material available. In such cases, we propose that the flowcell be re-hybridized and sequenced again using our Long Template Protocol. Alternatively, we discuss how analysis can be repeated from saved sequencing images using the Long Template Protocol to increase accuracy. PMID:25860802
A Systematic Evaluation of Blood Serum and Plasma Pre-Analytics for Metabolomics Cohort Studies
Jobard, Elodie; Trédan, Olivier; Postoly, Déborah; André, Fabrice; Martin, Anne-Laure; Elena-Herrmann, Bénédicte; Boyault, Sandrine
2016-01-01
The recent thriving development of biobanks and associated high-throughput phenotyping studies requires the elaboration of large-scale approaches for monitoring biological sample quality and compliance with standard protocols. We present a metabolomic investigation of human blood samples that delineates pitfalls and guidelines for the collection, storage and handling procedures for serum and plasma. A series of eight pre-processing technical parameters is systematically investigated along variable ranges commonly encountered across clinical studies. While metabolic fingerprints, as assessed by nuclear magnetic resonance, are not significantly affected by altered centrifugation parameters or delays between sample pre-processing (blood centrifugation) and storage, our metabolomic investigation highlights that both the delay and storage temperature between blood draw and centrifugation are the primary parameters impacting serum and plasma metabolic profiles. Storing the blood drawn at 4 °C is shown to be a reliable routine to confine variability associated with idle time prior to sample pre-processing. Based on their fine sensitivity to pre-analytical parameters and protocol variations, metabolic fingerprints could be exploited as valuable ways to determine compliance with standard procedures and quality assessment of blood samples within large multi-omic clinical and translational cohort studies. PMID:27929400
Gehlen, Heidrun; Bradaric, Zrinkja
2013-01-01
The evaluation of plasma ACTH and the dexamethasone suppression test are considered the methods of choice to evaluate the course of therapy of pituitary pars intermedia dysfunction (PPID). Sampling protocols as well as vacutainers for analysis differ between the laboratories. To evaluate the reproducability of plasma ACTH measurement between four different laboratories (A, B, C, D) in Germany as well as within the laboratories themselves, ten horses with previously diagnosed PPID and four healthy horses were sampled and analyzed. Each laboratory received two differently labeled samples of each horse which had been drawn at the same time (blinded samples). Sampling was performed in the morning at the same time. The sampling vacutainers (with and without addition of coagulation and proteinase inhibitors) and postage of the samples was performed according to laboratory standards. In one laboratory the influence of the time of centrifugation (immediately after taking blood versus after one hour) was determined. The samples were processed and analyzed according to laboratory protocols. Determination of ACTH levels was performed using chemiluminescence immunoassay. In total 132 blood samples were analyzed. The results of doubled blood samples of the same horse showed a standard deviation ranging from +/- 6 to +/- 27 pg/ml within the laboratories (Ø 19,29 pg/ml). The standard deviation of the repeatability of the variation coefficient was 13,48%. Blood samples of the same horse resulted in ACTH levels of 121 pg/ml in the first probe and in < 5 pg/ml in the second probe. Standard deviation of measured ACTH values between the laboratories was +/- 26,4 pg/ml (Ø 27,44 pg/ml). The standard deviation of the reproducibility of the variation coefficient was 18,36%. In a 20 year old gelding the lowest ACTH value was 60.9 pg/ml whereas the highest measured value was 108 pg/ml. Immediate centrifugation of blood samples resulted in significantly higher ACTH values at an average of 11.6 pg/ml. The additional use of proteinase inhibitors (aprotinine) showed no influence on ACTH levels in this study.
High-throughput real-time quantitative reverse transcription PCR.
Bookout, Angie L; Cummins, Carolyn L; Mangelsdorf, David J; Pesola, Jean M; Kramer, Martha F
2006-02-01
Extensive detail on the application of the real-time quantitative polymerase chain reaction (QPCR) for the analysis of gene expression is provided in this unit. The protocols are designed for high-throughput, 384-well-format instruments, such as the Applied Biosystems 7900HT, but may be modified to suit any real-time PCR instrument. QPCR primer and probe design and validation are discussed, and three relative quantitation methods are described: the standard curve method, the efficiency-corrected DeltaCt method, and the comparative cycle time, or DeltaDeltaCt method. In addition, a method is provided for absolute quantification of RNA in unknown samples. RNA standards are subjected to RT-PCR in the same manner as the experimental samples, thus accounting for the reaction efficiencies of both procedures. This protocol describes the production and quantitation of synthetic RNA molecules for real-time and non-real-time RT-PCR applications.
Favorable Geochemistry from Springs and Wells in Colorado
Richard E. Zehner
2012-02-01
This layer contains favorable geochemistry for high-temperature geothermal systems, as interpreted by Richard "Rick" Zehner. The data is compiled from the data obtained from the USGS. The original data set combines 15,622 samples collected in the State of Colorado from several sources including 1) the original Geotherm geochemical database, 2) USGS NWIS (National Water Information System), 3) Colorado Geological Survey geothermal sample data, and 4) original samples collected by R. Zehner at various sites during the 2011 field season. These samples are also available in a separate shapefile FlintWaterSamples.shp. Data from all samples were reportedly collected using standard water sampling protocols (filtering through 0.45 micron filter, etc.) Sample information was standardized to ppm (micrograms/liter) in spreadsheet columns. Commonly-used cation and silica geothermometer temperature estimates are included.
The purpose of this SOP is to describe the procedures for collecting surface wipe samples inside a home for analysis of either metals or pesticides. This procedure covers the preparation of the surface wipe material and field activities. This protocol was followed to ensure con...
A Constrained and Versioned Data Model for TEAM Data
NASA Astrophysics Data System (ADS)
Andelman, S.; Baru, C.; Chandra, S.; Fegraus, E.; Lin, K.
2009-04-01
The objective of the Tropical Ecology Assessment and Monitoring Network (www.teamnetwork.org) is "To generate real time data for monitoring long-term trends in tropical biodiversity through a global network of TEAM sites (i.e. field stations in tropical forests), providing an early warning system on the status of biodiversity to effectively guide conservation action". To achieve this, the TEAM Network operates by collecting data via standardized protocols at TEAM Sites. The standardized TEAM protocols include the Climate, Vegetation and Terrestrial Vertebrate Protocols. Some sites also implement additional protocols. There are currently 7 TEAM Sites with plans to grow the network to 15 by June 30, 2009 and 50 TEAM Sites by the end of 2010. At each TEAM Site, data is gathered as defined by the protocols and according to a predefined sampling schedule. The TEAM data is organized and stored in a database based on the TEAM spatio-temporal data model. This data model is at the core of the TEAM Information System - it consumes and executes spatio-temporal queries, and analytical functions that are performed on TEAM data, and defines the object data types, relationships and operations that maintain database integrity. The TEAM data model contains object types including types for observation objects (e.g. bird, butterfly and trees), sampling unit, person, role, protocol, site and the relationship of these object types. Each observation data record is a set of attribute values of an observation object and is always associated with a sampling unit, an observation timestamp or time interval, a versioned protocol and data collectors. The operations on the TEAM data model can be classified as read operations, insert operations and update operations. Following are some typical operations: The operation get(site, protocol, [sampling unit block, sampling unit,] start time, end time) returns all data records using the specified protocol and collected at the specified site, block, sampling unit and time range. The operation insertSamplingUnit(sampling unit, site, protocol) saves a new sampling unit into the data model and links it with the site and protocol. The operation updateSampligUnit(sampling_unit_id, attribute, value) changes the attribute (e.g. latitude or longitude) of the sampling unit to the specified value. The operation insertData(observation record, site, protocol, sampling unit, timestamps, data collectors) saves a new observation record into the database and associates it with specified objects. The operation updateData(protocol, data_id, attribute, value) modifies the attribute of an existing observation record to the specified value. All the insert or update operations require: 1) authorization to ensure the user has necessary privileges to perform the operation; 2) timestamp validation to ensure the observation timestamps are in the designated time range specified in the sampling schedule; 3) data validation to check that the data records use correct taxonomy terms and data values. No authorization is performed for get operations, but under some specific condition, a username may be required for the purpose of authentication. Along with the validations above, the TEAM data model also supports human based data validation on observed data through the Data Review subsystem to ensure data quality. The data review is implemented by adding two attributes review_tag and review_comment to each observation data record. The attribute review_tag is used by a reviewer to specify the quality of data, and the attribute review_comment is for reviewers to give more information when a problem is identified. The review_tag attribute can be populated by either the system conducting QA/QC tests or by pre-specified scientific experts. The following is the review operation, which is actually a special case of the operation updateData: The operation updateReview(protocol, data_id, judgment, comment) sets the attribute review_tag and review_comment to the specified values. By systematically tracking every step, The TEAM data model can roll back to any previous state. This is achieved by introducing a historical data container for each editable object type. When the operation updateData is applied to an object to modify its attribute, the object will be tagged with the current timestamp and the name of the user who conducts the operation, the tagged object will then be moved into the historical data container, and finally a new object will be created with the new value for the specified attribute. The diagram illustrates the architecture of the TEAM data management system. A data collector can use the Data Ingestion subsystem to load new data records into the TEAM data model. The system establishes a first level of review (i.e. meets minimum data standards via QA/QC tests). Further review is done via experts and they can verify and provide their comments on data records through the Data Review subsystem. The data editor can then address data records based on the reviewer's comments. Users can use the Data Query and Download application to find data by sites, protocols and time ranges. The Data Query and Download system packages selected data with the data license and important metadata information into a single package and delivers it to the user.
de Muinck, Eric J; Trosvik, Pål; Gilfillan, Gregor D; Hov, Johannes R; Sundaram, Arvind Y M
2017-07-06
Advances in sequencing technologies and bioinformatics have made the analysis of microbial communities almost routine. Nonetheless, the need remains to improve on the techniques used for gathering such data, including increasing throughput while lowering cost and benchmarking the techniques so that potential sources of bias can be better characterized. We present a triple-index amplicon sequencing strategy to sequence large numbers of samples at significantly lower c ost and in a shorter timeframe compared to existing methods. The design employs a two-stage PCR protocol, incorpo rating three barcodes to each sample, with the possibility to add a fourth-index. It also includes heterogeneity spacers to overcome low complexity issues faced when sequencing amplicons on Illumina platforms. The library preparation method was extensively benchmarked through analysis of a mock community in order to assess biases introduced by sample indexing, number of PCR cycles, and template concentration. We further evaluated the method through re-sequencing of a standardized environmental sample. Finally, we evaluated our protocol on a set of fecal samples from a small cohort of healthy adults, demonstrating good performance in a realistic experimental setting. Between-sample variation was mainly related to batch effects, such as DNA extraction, while sample indexing was also a significant source of bias. PCR cycle number strongly influenced chimera formation and affected relative abundance estimates of species with high GC content. Libraries were sequenced using the Illumina HiSeq and MiSeq platforms to demonstrate that this protocol is highly scalable to sequence thousands of samples at a very low cost. Here, we provide the most comprehensive study of performance and bias inherent to a 16S rRNA gene amplicon sequencing method to date. Triple-indexing greatly reduces the number of long custom DNA oligos required for library preparation, while the inclusion of variable length heterogeneity spacers minimizes the need for PhiX spike-in. This design results in a significant cost reduction of highly multiplexed amplicon sequencing. The biases we characterize highlight the need for highly standardized protocols. Reassuringly, we find that the biological signal is a far stronger structuring factor than the various sources of bias.
Porcelain surface conditioning protocols and shear bond strength of orthodontic brackets.
Lestrade, Ashley M; Ballard, Richard W; Xu, Xiaoming; Yu, Qingzhao; Kee, Edwin L; Armbruster, Paul C
2016-05-01
The objective of the present study was to determine which of six bonding protocols yielded a clinically acceptable shear bond strength (SBS) of metal orthodontic brackets to CAD/CAM lithium disilicate porcelain restorations. A secondary aim was to determine which bonding protocol produced the least surface damage at debond. Sixty lithium disilicate samples were fabricated to replicate the facial surface of a mandibular first molar using a CEREC CAD/CAM machine. The samples were split into six test groups, each of which received different mechanical/chemical pretreatment protocols to roughen the porcelain surface prior to bonding a molar orthodontic attachment. Shear bond strength testing was conducted using an Instron machine. The mean, maximum, minimal, and standard deviation SBS values for each sample group including an enamel control were calculated. A t-test was used to evaluate the statistical significance between the groups. No significant differences were found in SBS values, with the exception of surface roughening with a green stone prior to HFA and silane treatment. This protocol yielded slightly higher bond strength which was statistically significant. Chemical treatment alone with HFA/silane yielded SBS values within an acceptable clinical range to withstand forces applied by orthodontic treatment and potentially eliminates the need to mechanically roughen the ceramic surface.
Zhou, Menglan; Yang, Qiwen; Kudinha, Timothy; Sun, Liying; Zhang, Rui; Liu, Chang; Yu, Shuying; Xiao, Meng; Kong, Fanrong; Zhao, Yupei; Xu, Ying-Chun
2017-01-01
Background: Bloodstream infection is a major cause of morbidity and mortality in hospitalized patients worldwide. Delays in the identification of microorganisms often leads to a poor prognosis. The application of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) directly to blood culture (BC) broth can potentially identify bloodstream infections earlier, and facilitate timely management. Methods: We developed an "in-house" (IH) protocol for direct MALDI-TOF MS based identification of organisms in positive BCs. The IH protocol was initially evaluated and improved with spiked BC samples, and its performance was compared with the commercial Sepsityper™ kit using both traditional and modified cut-off values. We then studied in parallel the performance of the IH protocol and the colony MS identifications in positive clinical BC samples using only modified cut-off values. All discrepancies were investigated by "gold standard" of gene sequencing. Results: In 54 spiked BC samples, the IH method showed comparable results with Sepsityper™ after applying modified cut-off values. Specifically, accurate species and genus level identification was achieved in 88.7 and 3.9% of all the clinical monomicrobial BCs (284/301, 94.4%), respectively. The IH protocol exhibited superior performance for Gram negative bacteria than for Gram positive bacteria (92.8 vs. 82.4%). For anaerobes and yeasts, accurate species identification was achieved in 80.0 and 90.0% of the cases, respectively. For polymicrobial cultures (17/301, 5.6%), MALDI-TOF MS correctly identified a single species present in all the polymicrobial BCs under the Standard mode, while using the MIXED method, two species were correctly identified in 52.9% of the samples. Comparisons based on BC bottle type, showed that the BACTEC™ Lytic/10 Anaerobic/F culture vials performed the best. Conclusion: Our study provides a novel and effective sample preparation method for MALDI-TOF MS direct identification of pathogens from positive BC vials, with a lower cost ($1.5 vs. $ 7) albeit a slightly more laborious extracting process (an extra 15 min) compared with Sepsityper™ kit.
Field, Christopher R.; Lubrano, Adam; Woytowitz, Morgan; Giordano, Braden C.; Rose-Pehrsson, Susan L.
2014-01-01
The direct liquid deposition of solution standards onto sorbent-filled thermal desorption tubes is used for the quantitative analysis of trace explosive vapor samples. The direct liquid deposition method yields a higher fidelity between the analysis of vapor samples and the analysis of solution standards than using separate injection methods for vapors and solutions, i.e., samples collected on vapor collection tubes and standards prepared in solution vials. Additionally, the method can account for instrumentation losses, which makes it ideal for minimizing variability and quantitative trace chemical detection. Gas chromatography with an electron capture detector is an instrumentation configuration sensitive to nitro-energetics, such as TNT and RDX, due to their relatively high electron affinity. However, vapor quantitation of these compounds is difficult without viable vapor standards. Thus, we eliminate the requirement for vapor standards by combining the sensitivity of the instrumentation with a direct liquid deposition protocol to analyze trace explosive vapor samples. PMID:25145416
Field, Christopher R; Lubrano, Adam; Woytowitz, Morgan; Giordano, Braden C; Rose-Pehrsson, Susan L
2014-07-25
The direct liquid deposition of solution standards onto sorbent-filled thermal desorption tubes is used for the quantitative analysis of trace explosive vapor samples. The direct liquid deposition method yields a higher fidelity between the analysis of vapor samples and the analysis of solution standards than using separate injection methods for vapors and solutions, i.e., samples collected on vapor collection tubes and standards prepared in solution vials. Additionally, the method can account for instrumentation losses, which makes it ideal for minimizing variability and quantitative trace chemical detection. Gas chromatography with an electron capture detector is an instrumentation configuration sensitive to nitro-energetics, such as TNT and RDX, due to their relatively high electron affinity. However, vapor quantitation of these compounds is difficult without viable vapor standards. Thus, we eliminate the requirement for vapor standards by combining the sensitivity of the instrumentation with a direct liquid deposition protocol to analyze trace explosive vapor samples.
Unice, Kenneth M; Kreider, Marisa L; Panko, Julie M
2012-11-08
Pyrolysis(pyr)-GC/MS analysis of characteristic thermal decomposition fragments has been previously used for qualitative fingerprinting of organic sources in environmental samples. A quantitative pyr-GC/MS method based on characteristic tire polymer pyrolysis products was developed for tread particle quantification in environmental matrices including soil, sediment, and air. The feasibility of quantitative pyr-GC/MS analysis of tread was confirmed in a method evaluation study using artificial soil spiked with known amounts of cryogenically generated tread. Tread concentration determined by blinded analyses was highly correlated (r2 ≥ 0.88) with the known tread spike concentration. Two critical refinements to the initial pyrolysis protocol were identified including use of an internal standard and quantification by the dimeric markers vinylcyclohexene and dipentene, which have good specificity for rubber polymer with no other appreciable environmental sources. A novel use of deuterated internal standards of similar polymeric structure was developed to correct the variable analyte recovery caused by sample size, matrix effects, and ion source variability. The resultant quantitative pyr-GC/MS protocol is reliable and transferable between laboratories.
Standardized methods for Grand Canyon fisheries research 2015
Persons, William R.; Ward, David L.; Avery, Luke A.
2013-01-01
This document presents protocols and guidelines to persons sampling fishes in the Grand Canyon, to help ensure consistency in fish handling, fish tagging, and data collection among different projects and organizations. Most such research and monitoring projects are conducted under the general umbrella of the Glen Canyon Dam Adaptive Management Program and include studies by the U.S. Geological Survey (USGS), U.S. Fish and Wildlife Service (FWS), National Park Service (NPS), the Arizona Game and Fish Department (AGFD), various universities, and private contractors. This document is intended to provide guidance to fieldworkers regarding protocols that may vary from year to year depending on specific projects and objectives. We also provide herein documentation of standard methods used in the Grand Canyon that can be cited in scientific publications, as well as a summary of changes in protocols since the document was first created in 2002.
Price, Travis K.; Dune, Tanaka; Hilt, Evann E.; Thomas-White, Krystal J.; Kliethermes, Stephanie; Brincat, Cynthia; Brubaker, Linda; Wolfe, Alan J.
2016-01-01
Enhanced quantitative urine culture (EQUC) detects live microorganisms in the vast majority of urine specimens reported as “no growth” by the standard urine culture protocol. Here, we evaluated an expanded set of EQUC conditions (expanded-spectrum EQUC) to identify an optimal version that provides a more complete description of uropathogens in women experiencing urinary tract infection (UTI)-like symptoms. One hundred fifty adult urogynecology patient-participants were characterized using a self-completed validated UTI symptom assessment (UTISA) questionnaire and asked “Do you feel you have a UTI?” Women responding negatively were recruited into the no-UTI cohort, while women responding affirmatively were recruited into the UTI cohort; the latter cohort was reassessed with the UTISA questionnaire 3 to 7 days later. Baseline catheterized urine samples were plated using both standard urine culture and expanded-spectrum EQUC protocols: standard urine culture inoculated at 1 μl onto 2 agars incubated aerobically; expanded-spectrum EQUC inoculated at three different volumes of urine onto 7 combinations of agars and environments. Compared to expanded-spectrum EQUC, standard urine culture missed 67% of uropathogens overall and 50% in participants with severe urinary symptoms. Thirty-six percent of participants with missed uropathogens reported no symptom resolution after treatment by standard urine culture results. Optimal detection of uropathogens could be achieved using the following: 100 μl of urine plated onto blood (blood agar plate [BAP]), colistin-nalidixic acid (CNA), and MacConkey agars in 5% CO2 for 48 h. This streamlined EQUC protocol achieved 84% uropathogen detection relative to 33% detection by standard urine culture. The streamlined EQUC protocol improves detection of uropathogens that are likely relevant for symptomatic women, giving clinicians the opportunity to receive additional information not currently reported using standard urine culture techniques. PMID:26962083
Comparison of Two Methods of RNA Extraction from Formalin-Fixed Paraffin-Embedded Tissue Specimens
Gouveia, Gisele Rodrigues; Ferreira, Suzete Cleusa; Ferreira, Jerenice Esdras; Siqueira, Sheila Aparecida Coelho; Pereira, Juliana
2014-01-01
The present study aimed to compare two different methods of extracting RNA from formalin-fixed paraffin-embedded (FFPE) specimens of diffuse large B-cell lymphoma (DLBCL). We further aimed to identify possible influences of variables—such as tissue size, duration of paraffin block storage, fixative type, primers used for cDNA synthesis, and endogenous genes tested—on the success of amplification from the samples. Both tested protocols used the same commercial kit for RNA extraction (the RecoverAll Total Nucleic Acid Isolation Optimized for FFPE Samples from Ambion). However, the second protocol included an additional step of washing with saline buffer just after sample rehydration. Following each protocol, we compared the RNA amount and purity and the amplification success as evaluated by standard PCR and real-time PCR. The results revealed that the extra washing step added to the RNA extraction process resulted in significantly improved RNA quantity and quality and improved success of amplification from paraffin-embedded specimens. PMID:25105117
Garcia Hejl, Carine; Ramirez, Jose Manuel; Vest, Philippe; Chianea, Denis; Renard, Christophe
2014-09-01
Laboratories working towards accreditation by the International Standards Organization (ISO) 15189 standard are required to demonstrate the validity of their analytical methods. The different guidelines set by various accreditation organizations make it difficult to provide objective evidence that an in-house method is fit for the intended purpose. Besides, the required performance characteristics tests and acceptance criteria are not always detailed. The laboratory must choose the most suitable validation protocol and set the acceptance criteria. Therefore, we propose a validation protocol to evaluate the performance of an in-house method. As an example, we validated the process for the detection and quantification of lead in whole blood by electrothermal absorption spectrometry. The fundamental parameters tested were, selectivity, calibration model, precision, accuracy (and uncertainty of measurement), contamination, stability of the sample, reference interval, and analytical interference. We have developed a protocol that has been applied successfully to quantify lead in whole blood by electrothermal atomic absorption spectrometry (ETAAS). In particular, our method is selective, linear, accurate, and precise, making it suitable for use in routine diagnostics.
Verkest, K R; Fleeman, L M; Rand, J S; Morton, J M
2010-10-01
There is need for simple, inexpensive measures of glucose tolerance, insulin sensitivity, and insulin secretion in dogs. The aim of this study was to estimate the closeness of correlation between fasting and dynamic measures of insulin sensitivity and insulin secretion, the precision of fasting measures, and the agreement between results of standard and simplified glucose tolerance tests in dogs. A retrospective descriptive study using 6 naturally occurring obese and 6 lean dogs was conducted. Data from frequently sampled intravenous glucose tolerance tests (FSIGTTs) in 6 obese and 6 lean client-owned dogs were used to calculate HOMA, QUICKI, fasting glucose and insulin concentrations. Fasting measures of insulin sensitivity and secretion were compared with MINMOD analysis of FSIGTTs using Pearson correlation coefficients, and they were evaluated for precision by the discriminant ratio. Simplified sampling protocols were compared with standard FSIGTTs using Lin's concordance correlation coefficients, limits of agreement, and Pearson correlation coefficients. All fasting measures except fasting plasma glucose concentration were moderately correlated with MINMOD-estimated insulin sensitivity (|r| = 0.62-0.80; P < 0.03), and those that combined fasting insulin and glucose were moderately closely correlated with MINMOD-estimated insulin secretion (r = 0.60-0.79; P < 0.04). HOMA calculated using the nonlinear formulae had the closest estimated correlation (r = 0.77 and 0.74) and the best discrimination for insulin sensitivity and insulin secretion (discriminant ratio 4.4 and 3.4, respectively). Simplified sampling protocols with half as many samples collected over 3 h had close agreement with the full sampling protocol. Fasting measures and simplified intravenous glucose tolerance tests reflect insulin sensitivity and insulin secretion derived from frequently sampled glucose tolerance tests with MINMOD analysis in dogs. Copyright 2010 Elsevier Inc. All rights reserved.
The purpose of this SOP is to describe the procedures for collecting surface wipe samples inside a home for analysis of either metals or pesticides. This procedure covers the preparation of the surface wipe material and field activities. This protocol was followed to ensure con...
Advanced Combat Helmet Technical Assessment
2013-05-29
Lastly, we assessed the participation of various stakeholders and industry experts such as active ACH manufacturers and test facilities. Findings... industrially accepted American National Standards Institute (ANSI Z1.4-2008, Sampling Visit us on the web at www.dodig.mil Results in Brief Advanced...statistically principled approach and the lot acceptance test protocol adopts a widely established and industrially accepted sampling procedure. We
ERIC Educational Resources Information Center
Southwood, Frenette; Russell, Ann F.
2004-01-01
The spontaneous language sample forms an important part of the language evaluation protocol (M. Dunn, J. Flax, M. Sliwinski, & D. Aram, 1996; J. L. Evans & H. K. Craig, 1992; L. E. Evans & J. Miller, 1999) because of the limitations of standardized language tests and their unavailability in certain languages, such as Afrikaans. This study examined…
Go, Young-Mi; Walker, Douglas I; Liang, Yongliang; Uppal, Karan; Soltow, Quinlyn A; Tran, ViLinh; Strobel, Frederick; Quyyumi, Arshed A; Ziegler, Thomas R; Pennell, Kurt D; Miller, Gary W; Jones, Dean P
2015-12-01
The exposome is the cumulative measure of environmental influences and associated biological responses throughout the lifespan, including exposures from the environment, diet, behavior, and endogenous processes. A major challenge for exposome research lies in the development of robust and affordable analytic procedures to measure the broad range of exposures and associated biologic impacts occurring over a lifetime. Biomonitoring is an established approach to evaluate internal body burden of environmental exposures, but use of biomonitoring for exposome research is often limited by the high costs associated with quantification of individual chemicals. High-resolution metabolomics (HRM) uses ultra-high resolution mass spectrometry with minimal sample preparation to support high-throughput relative quantification of thousands of environmental, dietary, and microbial chemicals. HRM also measures metabolites in most endogenous metabolic pathways, thereby providing simultaneous measurement of biologic responses to environmental exposures. The present research examined quantification strategies to enhance the usefulness of HRM data for cumulative exposome research. The results provide a simple reference standardization protocol in which individual chemical concentrations in unknown samples are estimated by comparison to a concurrently analyzed, pooled reference sample with known chemical concentrations. The approach was tested using blinded analyses of amino acids in human samples and was found to be comparable to independent laboratory results based on surrogate standardization or internal standardization. Quantification was reproducible over a 13-month period and extrapolated to thousands of chemicals. The results show that reference standardization protocol provides an effective strategy that will enhance data collection for cumulative exposome research. In principle, the approach can be extended to other types of mass spectrometry and other analytical methods. © The Author 2015. Published by Oxford University Press on behalf of the Society of Toxicology. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Go, Young-Mi; Walker, Douglas I.; Liang, Yongliang; Uppal, Karan; Soltow, Quinlyn A.; Tran, ViLinh; Strobel, Frederick; Quyyumi, Arshed A.; Ziegler, Thomas R.; Pennell, Kurt D.; Miller, Gary W.; Jones, Dean P.
2015-01-01
The exposome is the cumulative measure of environmental influences and associated biological responses throughout the lifespan, including exposures from the environment, diet, behavior, and endogenous processes. A major challenge for exposome research lies in the development of robust and affordable analytic procedures to measure the broad range of exposures and associated biologic impacts occurring over a lifetime. Biomonitoring is an established approach to evaluate internal body burden of environmental exposures, but use of biomonitoring for exposome research is often limited by the high costs associated with quantification of individual chemicals. High-resolution metabolomics (HRM) uses ultra-high resolution mass spectrometry with minimal sample preparation to support high-throughput relative quantification of thousands of environmental, dietary, and microbial chemicals. HRM also measures metabolites in most endogenous metabolic pathways, thereby providing simultaneous measurement of biologic responses to environmental exposures. The present research examined quantification strategies to enhance the usefulness of HRM data for cumulative exposome research. The results provide a simple reference standardization protocol in which individual chemical concentrations in unknown samples are estimated by comparison to a concurrently analyzed, pooled reference sample with known chemical concentrations. The approach was tested using blinded analyses of amino acids in human samples and was found to be comparable to independent laboratory results based on surrogate standardization or internal standardization. Quantification was reproducible over a 13-month period and extrapolated to thousands of chemicals. The results show that reference standardization protocol provides an effective strategy that will enhance data collection for cumulative exposome research. In principle, the approach can be extended to other types of mass spectrometry and other analytical methods. PMID:26358001
Han, Yongming; Chen, Antony; Cao, Junji; Fung, Kochy; Ho, Fai; Yan, Beizhan; Zhan, Changlin; Liu, Suixin; Wei, Chong; An, Zhisheng
2013-01-01
Quantifying elemental carbon (EC) content in geological samples is challenging due to interferences of crustal, salt, and organic material. Thermal/optical analysis, combined with acid pretreatment, represents a feasible approach. However, the consistency of various thermal/optical analysis protocols for this type of samples has never been examined. In this study, urban street dust and soil samples from Baoji, China were pretreated with acids and analyzed with four thermal/optical protocols to investigate how analytical conditions and optical correction affect EC measurement. The EC values measured with reflectance correction (ECR) were found always higher and less sensitive to temperature program than the EC values measured with transmittance correction (ECT). A high-temperature method with extended heating times (STN120) showed the highest ECT/ECR ratio (0.86) while a low-temperature protocol (IMPROVE-550), with heating time adjusted for sample loading, showed the lowest (0.53). STN ECT was higher than IMPROVE ECT, in contrast to results from aerosol samples. A higher peak inert-mode temperature and extended heating times can elevate ECT/ECR ratios for pretreated geological samples by promoting pyrolyzed organic carbon (PyOC) removal over EC under trace levels of oxygen. Considering that PyOC within filter increases ECR while decreases ECT from the actual EC levels, simultaneous ECR and ECT measurements would constrain the range of EC loading and provide information on method performance. Further testing with standard reference materials of common environmental matrices supports the findings. Char and soot fractions of EC can be further separated using the IMPROVE protocol. The char/soot ratio was lower in street dusts (2.2 on average) than in soils (5.2 on average), most likely reflecting motor vehicle emissions. The soot concentrations agreed with EC from CTO-375, a pure thermal method.
Amendola, Alessandra; Bloisi, Maria; Marsella, Patrizia; Sabatini, Rosella; Bibbò, Angela; Angeletti, Claudio; Capobianchi, Maria Rosaria
2011-09-01
Numerous studies investigating clinical significance of HIV-1 minimal residual viremia (MRV) suggest potential utility of assays more sensitive than those routinely used to monitor viral suppression. However currently available methods, based on different technologies, show great variation in detection limit and input plasma volume, and generally suffer from lack of standardization. In order to establish new tools suitable for routine quantification of minimal residual viremia in patients under virological suppression, some modifications were introduced into standard procedure of the Abbott RealTime HIV-1 assay leading to a "modified" and an "ultrasensitive" protocols. The following modifications were introduced: calibration curve extended towards low HIV-1 RNA concentration; 4 fold increased sample volume by concentrating starting material; reduced volume of internal control; adoption of "open-mode" software for quantification. Analytical performances were evaluated using the HIV-1 RNA Working Reagent 1 for NAT assays (NIBSC). Both tests were applied to clinical samples from virologically suppressed patients. The "modified" and the "ultrasensitive" configurations of the assay reached a limit of detection of 18.8 (95% CI: 11.1-51.0 cp/mL) and 4.8 cp/mL (95% CI: 2.6-9.1 cp/mL), respectively, with high precision and accuracy. In clinical samples from virologically suppressed patients, "modified" and "ultrasensitive" protocols allowed to detect and quantify HIV RNA in 12.7% and 46.6%, respectively, of samples resulted "not-detectable", and in 70.0% and 69.5%, respectively, of samples "detected <40 cp/mL" in the standard assay. The "modified" and "ultrasensitive" assays are precise and accurate, and easily adoptable in routine diagnostic laboratories for measuring MRV. Copyright © 2011 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blake, Thomas A.; Johnson, Timothy J.; Tonkyn, Russell G.
Infrared integrating sphere measurements of solid samples are important in providing reference data for contact, standoff and remote sensing applications. At the Pacific Northwest National Laboratory (PNNL) we have developed protocols to measure both the directional-hemispherical ( and diffuse (d) reflectances of powders, liquids, and disks of powders and solid materials using a commercially available, matte gold-coated integrating sphere and Fourier transform infrared spectrometer. Detailed descriptions of the sphere alignment and its use for making these reflectance measurements are given. Diffuse reflectance values were found to be dependent on the bidirectional reflection distribution function (BRDF) of the sample and themore » solid angle intercepted by the sphere’s specular exclusion port. To determine how well the sphere and protocols produce quantitative reflectance data, measurements were made of three diffuse and two specular standards prepared by the National institute of Standards and Technology (NIST, USA), LabSphere Infragold and Spectralon standards, hand-loaded sulfur and talc powder samples, and water. The five NIST standards behaved as expected: the three diffuse standards had a high degree of “diffuseness,” d/ = D > 0.9, whereas the two specular standards had D ≤ 0.03. The average absolute differences between the NIST and PNNL measurements of the NIST standards for both directional-hemispherical and diffuse reflectances are on the order of 0.01 reflectance units. Other quantitative differences between the PNNL-measured and calibration (where available) or literature reflectance values for these standards and materials are given and the possible origins of discrepancies are discussed. Random uncertainties and estimates of systematic uncertainties are presented. Corrections necessary to provide better agreement between the PNNL reflectance values as measured for the NIST standards and the NIST reflectance values for these same standards are also discussed.« less
Publication trends of study protocols in rehabilitation.
Jesus, Tiago S; Colquhoun, Heather L
2017-09-04
Growing evidence points for the need to publish study protocols in the health field. To observe whether the growing interest in publishing study protocols in the broader health field has been translated into increased publications of rehabilitation study protocols. Observational study using publication data and its indexation in PubMed. Not applicable. Not applicable. PubMed was searched with appropriate combinations of Medical Subject Headings up to December 2014. The effective presence of study protocols was manually screened. Regression models analyzed the yearly growth of publications. Two-sample Z-tests analyzed whether the proportion of Systematic Reviews (SRs) and Randomized Controlled Trials (RCTs) among study protocols differed from that of the same designs for the broader rehabilitation research. Up to December 2014, 746 publications of rehabilitation study protocols were identified, with an exponential growth since 2005 (r2=0.981; p<0.001). RCT protocols were the most common among rehabilitation study protocols (83%), while RCTs were significantly more prevalent among study protocols than among the broader rehabilitation research (83% vs. 35.8%; p<0.001). For SRs, the picture was reversed: significantly less common among study protocols (2.8% vs. 9.3%; p<0.001). Funding was more often reported by rehabilitation study protocols than the broader rehabilitation research (90% vs. 53.1%; p<0.001). Rehabilitation journals published a significantly lower share of rehabilitation study protocols than they did for the broader rehabilitation research (1.8% vs.16.7%; p<0.001). Identifying the reasons for these discrepancies and reverting unwarranted disparities (e.g. low rate of publication for rehabilitation SR protocols) are likely new avenues for rehabilitation research and its publication. SRs, particularly those aggregating RCT results, are considered the best standard of evidence to guide rehabilitation clinical practice; however, that standard can be improved in rigor and/or transparency if the publications of rehabilitation SRs protocols become more common.
Paredes, R Madelaine; Tadaki, Douglas K; Sooter, Amanda; Gamboni, Fabia; Sheppard, Forest
2018-01-01
Immunophenotyping of whole blood (WB) by flow cytometry (FC) is used clinically to assess a patient's immune status and also in biomedical research. Current protocols recommend storage of immunolabeled samples at 4°C with FC analysis to be completed within seven days. This data acquisition window can be extended to up to one year post-labeling, but this requires cryopreservation of the samples at ultra-low temperatures (≤-80°C or in liquid nitrogen). In this study we optimized a standardized cryopreservation protocol to enable preservation of immunolabeled, human WB samples at -20°C for FC and tested its effectiveness after 0, 5, 15 or 30days. Analysis of stored samples shows that this protocol effectively preserves immunolabeled WB samples and that the duration of storage has no effect on morphology, viability or frequency of WB cell subpopulations, and that the intensity of fluorescent signal from labeled extracellular markers is fully preserved for at least 15days, and up to 30days for some markers. We demonstrate that using this protocol, we are able to differentiate resting versus activated WB cells as demonstrated by detection of significantly increased expression of CD11b by myeloid cells in WB samples pretreated with LPS (100μg/mL for 12h). Finally, we show that this method allows for labeling and detection of the intracellular cytokine (IL-8) up to 30days following cryopreservation from myeloid cells, in previously labeled and cryopreserved WB samples. Copyright © 2017 Elsevier B.V. All rights reserved.
Llop, Pablo; Bonaterra, Anna; Peñalver, Javier; López, María M.
2000-01-01
A novel method, which involves a nested PCR in a single closed tube, was developed for the sensitive detection of Erwinia amylovora in plant material. The external and internal primer pairs used had different annealing temperatures and directed the amplification of a specific DNA fragment from plasmid pEA29. The procedure involved two consecutive PCRs, the first of which was performed at a higher annealing temperature that allowed amplification only by the external primer pair. Using pure cultures of E. amylovora, the sensitivity of the nested PCR in one tube was similar to that of a standard nested PCR in two tubes. The specificity and sensitivity were greater than those of standard PCR procedures that used a single primer pair. The presence of inhibitors in plant material, very common in E. amylovora hosts, is overcome with this system in combination with a simple DNA extraction protocol because it eliminates many of the inhibitory compounds. In addition, it needs a very small sample volume (1 μl of DNA extracted). With 83 samples of naturally infected material, this method achieved better results than any other PCR technique: standard PCR detected 55% of positive samples, two-tube nested PCR detected 71% of positive samples, and nested PCR in a single closed tube detected 78% of positive samples. When analyzing asymptomatic plant material, the number of positive samples detected by the developed nested PCR was also the highest, compared with the PCR protocols indicated previously (17, 20, and 25% of 251 samples analyzed, respectively). This method is proposed for the detection of endophytic and epiphytic populations of E. amylovora in epidemiological studies and for routine use in quarantine surveys, due to its high sensitivity, specificity, speed, and simplicity. PMID:10788384
Biodiversity of Fungi : Inventory and Monitoring Methods
Mueller, G.M.; Bills, G.F.; Foster, M.S.
2004-01-01
Biodiversity of Fungi is essential for anyone collecting and/or monitoring any fungi. Fascinating and beautiful, fungi are vital components of nearly all ecosystems and impact human health and our economy in a myriad of ways. Standardized methods for documenting diversity and distribution have been lacking. An wealth of information, especially regrading sampling protocols, compiled by an international team of fungal biologists, make Biodiversity of Fungi an incredible and fundamental resource for the study of organismal biodiversity. Chapters cover everything from what is a fungus, to maintaining and organizing a permanent study collection with associated databases; from protocols for sampling slime molds to insect associated fungi; from fungi growing on and in animals and plants to mushrooms and truffles. The chapters are arranged both ecologically and by sampling method rather than by taxonomic group for ease of use. The information presented here is intended for everyone interested in fungi, anyone who needs tools to study them in nature including naturalists, land managers, ecologists, mycologists, and even citizen scientists and sophiscated amateurs. Fungi are among the most important organisms in the world; they play vital roles in ecosystem functions and have wide-ranging effects, both positive and negative, on humans and human-related activities. There are about 1.5 million species of fungi. The combination of fungal species and abundances in an ecosystem are often used as indicators of ecosystem health and as indicators of the effects of pollution and of different management and use plans. Because of their significance, it is important that these organisms be monitored. This book is the first comprehensive treatment of fungal inventory and monitoring, including standardized sampling protocols as well as information on study design, sample preservation, and data analysis.
ERIC Educational Resources Information Center
Balducci, Cristian; Mnich, Eva; McKee, Kevin J.; Lamura, Giovanni; Beckmann, Anke; Krevers, Barbro; Wojszel, Z. Beata; Nolan, Mike; Prouskas, Constantinos; Bien, Barbara; Oberg, Birgitta
2008-01-01
Purpose: The present study attempts to further validate the COPE Index on a large sample of carers drawn from six European countries. Design and Methods: We used a cross-sectional survey, with approximately 1,000 carers recruited in each of six countries by means of a common standard evaluation protocol. Our saturation recruitment of a designated…
Producing standard damaged DNA samples by heating: pitfalls and suggestions.
Fattorini, Paolo; Marrubini, Giorgio; Bonin, Serena; Bertoglio, Barbara; Grignani, Pierangela; Recchia, Elisa; Pitacco, Paola; Procopio, Francesca; Cantoni, Carolina; Pajnič, Irena Zupanič; Sorçaburu-Cigliero, Solange; Previderè, Carlo
2018-05-15
Heat-mediated hydrolysis of DNA is a simple and inexpensive method for producing damaged samples in vitro. Despite heat-mediated DNA hydrolysis is being widely used in forensic and clinical validation procedures, the lack of standardized procedures makes it impossible to compare the intra and inter-laboratory outcomes of the damaging treatments. In this work, a systematic approach to heat induced DNA hydrolysis was performed at 70 °C for 0-18 h to test the role both of the hydrolysis buffer and of the experimental conditions. Specifically, a trial DNA sample, resuspended in three different media (ultrapure water, 0.1% DEPC-water and, respectively, TE) was treated both in Eppendorf tubes ("Protocol P") and in Eppendorf tubes provided with screwcaps ("Protocol S"). The results of these comparative tests were assessed by normalization of the qPCR results. DEPC-water increased the degradation of the samples up to about 100 times when compared to the ultrapure water. Conversely, the TE protected the DNA from degradation whose level was about 1700 times lower than in samples treated in ultrapure water. Even the employment of the "Protocol S" affected the level of degradation, by consistently increasing it (up to about 180 times in DEPC-water). Thus, this comparative approach showed that even seemingly apparently trivial and often underestimated parameters modify the degradation level up to 2-3 orders of magnitude. The chemical-physical reasons of these findings are discussed together with the role of potential factors such as enhanced reactivity of CO 2 , ROS, NO x and pressure, which are likely to be involved. Since the intra and inter-laboratory comparison of the outcomes of the hydrolytic procedure is the first step toward its standardization, the normalization of the qPCR data by the UV/qPCR ratio seems to be the simplest and most reliable way to allow this. Finally, the supplying (provided with the commercial qPCR kits) of a DNA sample whose degree of degradation is well documented could be helpful in ISO/IEC 17025 validation procedures and in proficiency testing. Copyright © 2018 Elsevier Inc. All rights reserved.
Sochor, Jiri; Ryvolova, Marketa; Krystofova, Olga; Salas, Petr; Hubalek, Jaromir; Adam, Vojtech; Trnkova, Libuse; Havel, Ladislav; Beklova, Miroslava; Zehnalek, Josef; Provaznik, Ivo; Kizek, Rene
2010-11-29
The aim of this study was to describe behaviour, kinetics, time courses and limitations of the six different fully automated spectrometric methods--DPPH, TEAC, FRAP, DMPD, Free Radicals and Blue CrO5. Absorption curves were measured and absorbance maxima were found. All methods were calibrated using the standard compounds Trolox® and/or gallic acid. Calibration curves were determined (relative standard deviation was within the range from 1.5 to 2.5%). The obtained characteristics were compared and discussed. Moreover, the data obtained were applied to optimize and to automate all mentioned protocols. Automatic analyzer allowed us to analyse simultaneously larger set of samples, to decrease the measurement time, to eliminate the errors and to provide data of higher quality in comparison to manual analysis. The total time of analysis for one sample was decreased to 10 min for all six methods. In contrary, the total time of manual spectrometric determination was approximately 120 min. The obtained data provided good correlations between studied methods (R=0.97-0.99).
Wilson, Marcia H.; Rowe, Barbara L.; Gitzen, Robert A.; Wilson, Stephen K.; Paintner-Green, Kara J.
2014-01-01
As recommended by Oakley et al. (2003), this protocol provides a narrative and the rationale for selection of streams and rivers within the NGPN that will be measured for water quality, including dissolved oxygen, pH, specific conductivity, and temperature. Standard operating procedures (SOPs) that detail the steps to collect, manage, and disseminate the NGPN water quality data are in an accompanying document. The sampling design documented in this protocol may be updated as monitoring information is collected and interpreted, and as refinement of methodologies develop through time. In addition, evaluation of data and refinement of the program may necessitate potential changes of program objectives. Changes to the NGPN water quality protocols and SOPs will be carefully documented in a revision history log.
A review of blood sample handling and pre-processing for metabolomics studies.
Hernandes, Vinicius Veri; Barbas, Coral; Dudzik, Danuta
2017-09-01
Metabolomics has been found to be applicable to a wide range of clinical studies, bringing a new era for improving clinical diagnostics, early disease detection, therapy prediction and treatment efficiency monitoring. A major challenge in metabolomics, particularly untargeted studies, is the extremely diverse and complex nature of biological specimens. Despite great advances in the field there still exist fundamental needs for considering pre-analytical variability that can introduce bias to the subsequent analytical process and decrease the reliability of the results and moreover confound final research outcomes. Many researchers are mainly focused on the instrumental aspects of the biomarker discovery process, and sample related variables sometimes seem to be overlooked. To bridge the gap, critical information and standardized protocols regarding experimental design and sample handling and pre-processing are highly desired. Characterization of a range variation among sample collection methods is necessary to prevent results misinterpretation and to ensure that observed differences are not due to an experimental bias caused by inconsistencies in sample processing. Herein, a systematic discussion of pre-analytical variables affecting metabolomics studies based on blood derived samples is performed. Furthermore, we provide a set of recommendations concerning experimental design, collection, pre-processing procedures and storage conditions as a practical review that can guide and serve for the standardization of protocols and reduction of undesirable variation. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Justice-Allen, A; Trujillo, J; Goodell, G; Wilson, D
2011-07-01
The objective of this study was to further validate a SYBR PCR protocol for Mycoplasma spp. by comparing it with standard microbial culture in the detection of Mycoplasma spp. in bulk tank milk samples. Additionally, we identified Mycoplasma spp. present by analysis of PCR-generated amplicons [dissociation (melt) temperature (T(m)), length, and DNA sequence]. The research presented herein tests the hypothesis that the SYBR PCR protocol is as sensitive as conventional culture for the detection of Mycoplasma spp. in bulk tank milk samples. Mycoplasmas cause several important disease syndromes in cattle, including mastitis in dairy cows. The standard diagnostic method at the herd level has been microbial isolation of mycoplasmas on 1 of several specialized media and speciation through biochemical or immunological techniques; repeated sampling schemes are recommended. The development of a real-time SYBR PCR protocol offers advantages in decrease of time to detection, cost, and complexity. The T(m) of the double-stranded DNA generated from the PCR reaction was used to detect the presence of and tentatively identify the species of mycoplasmas other than Mycoplasma bovis. In the SYBR PCR protocol, the presence of multiple species of mycoplasmas is indicated by an atypical dissociation curve. Gel electrophoresis and sequencing of the amplicons was used to confirm the mycoplasma species present when a non-M. bovis organism was detected (T(m) not equal to M. bovis) and used to identify all the mycoplasma species present for the samples with atypical dissociation curves. Mycoplasma bovis was identified in 83% of SYBR PCR mycoplasma-positive bulk tank samples. Another mycoplasma was identified either alone or in addition to M. bovis in 25% of SYBR PCR mycoplasma-positive bulk tank milk samples. Four species of mycoplasma other than M. bovis (Mycoplasma alkalescens, Mycoplasma arginini, Mycoplasma bovigenitalium, and Mycoplasma gateae) were identified in bulk tank milk samples tested with this method. Five farms had 2 mycoplasma species occurring at different times in their bulk tanks. Two mycoplasma species were identified in the same bulk tank sample in 7 instances on 2 farms. The finding of multiple Mycoplasma spp. coexisting on a farm and even in the same bulk tank milk sample indicates that the clinical significance of multiple mycoplasma species in the pathology of intramammary infections should be investigated further. In comparison with conventional culture, the SYBR PCR protocol was slightly (but not statistically significantly) more sensitive in the detection of mycoplasmas in bulk tank milk. Copyright © 2011 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Leung, Yu Hang; Guo, Mu Yao; Ma, Angel P Y; Ng, Alan M C; Djurišić, Aleksandra B; Degger, Natalie; Leung, Frederick C C
2017-07-01
We investigated transmission electron microscopy artifacts obtained using standard sample preparation protocols applied to the investigation of Escherichia coli cells exposed to common nanomaterials, such as TiO 2 , Ag, ZnO, and MgO. While the common protocols for some nanomaterials result only in known issues of nanomaterial-independent generation of anomalous deposits due to fixation and staining, for others, there are reactions between the nanomaterial and chemicals used for post-fixation or staining. Only in the case of TiO 2 do we observe only the known issues of nanomaterial-independent generation of anomalous deposits due to exceptional chemical stability of this material. For the other three nanomaterials, different artifacts are observed. For each of those, we identify causes of the observed problems and suggest alternative sample preparation protocols to avoid artifacts arising from the sample preparation, which is essential for correct interpretation of the obtained images and drawing correct conclusions on cell-nanomaterial interactions. Finally, we propose modified sample preparation and characterization protocols for comprehensive and conclusive investigations of nanomaterial-cell interactions using electron microscopy and for obtaining clear and unambiguous revelation whether the nanomaterials studied penetrate the cells or accumulate at the cell membranes. In only the case of MgO and ZnO, the unambiguous presence of Zn and Mg could be observed inside the cells.
Lopez-Rendon, Xochitl; Zhang, Guozhi; Coudyzer, Walter; Develter, Wim; Bosmans, Hilde; Zanca, Federica
2017-11-01
To compare the lung and breast dose associated with three chest protocols: standard, organ-based tube current modulation (OBTCM) and fast-speed scanning; and to estimate the error associated with organ dose when modelling the longitudinal (z-) TCM versus the 3D-TCM in Monte Carlo simulations (MC) for these three protocols. Five adult and three paediatric cadavers with different BMI were scanned. The CTDI vol of the OBTCM and the fast-speed protocols were matched to the patient-specific CTDI vol of the standard protocol. Lung and breast doses were estimated using MC with both z- and 3D-TCM simulated and compared between protocols. The fast-speed scanning protocol delivered the highest doses. A slight reduction for breast dose (up to 5.1%) was observed for two of the three female cadavers with the OBTCM in comparison to the standard. For both adult and paediatric, the implementation of the z-TCM data only for organ dose estimation resulted in 10.0% accuracy for the standard and fast-speed protocols, while relative dose differences were up to 15.3% for the OBTCM protocol. At identical CTDI vol values, the standard protocol delivered the lowest overall doses. Only for the OBTCM protocol is the 3D-TCM needed if an accurate (<10.0%) organ dosimetry is desired. • The z-TCM information is sufficient for accurate dosimetry for standard protocols. • The z-TCM information is sufficient for accurate dosimetry for fast-speed scanning protocols. • For organ-based TCM schemes, the 3D-TCM information is necessary for accurate dosimetry. • At identical CTDI vol , the fast-speed scanning protocol delivered the highest doses. • Lung dose was higher in XCare than standard protocol at identical CTDI vol .
Chung, Jinyong; Yoo, Kwangsun; Lee, Peter; Kim, Chan Mi; Roh, Jee Hoon; Park, Ji Eun; Kim, Sang Joon; Seo, Sang Won; Shin, Jeong-Hyeon; Seong, Joon-Kyung; Jeong, Yong
2017-10-01
The use of different 3D T1-weighted magnetic resonance (T1 MR) imaging protocols induces image incompatibility across multicenter studies, negating the many advantages of multicenter studies. A few methods have been developed to address this problem, but significant image incompatibility still remains. Thus, we developed a novel and convenient method to improve image compatibility. W-score standardization creates quality reference values by using a healthy group to obtain normalized disease values. We developed a protocol-specific w-score standardization to control the protocol effect, which is applied to each protocol separately. We used three data sets. In dataset 1, brain T1 MR images of normal controls (NC) and patients with Alzheimer's disease (AD) from two centers, acquired with different T1 MR protocols, were used (Protocol 1 and 2, n = 45/group). In dataset 2, data from six subjects, who underwent MRI with two different protocols (Protocol 1 and 2), were used with different repetition times, echo times, and slice thicknesses. In dataset 3, T1 MR images from a large number of healthy normal controls (Protocol 1: n = 148, Protocol 2: n = 343) were collected for w-score standardization. The protocol effect and disease effect on subjects' cortical thickness were analyzed before and after the application of protocol-specific w-score standardization. As expected, different protocols resulted in differing cortical thickness measurements in both NC and AD subjects. Different measurements were obtained for the same subject when imaged with different protocols. Multivariate pattern difference between measurements was observed between the protocols. Classification accuracy between two protocols was nearly 90%. After applying protocol-specific w-score standardization, the differences between the protocols substantially decreased. Most importantly, protocol-specific w-score standardization reduced both univariate and multivariate differences in the images while maintaining the AD disease effect. Compared to conventional regression methods, our method showed the best performance for in terms of controlling the protocol effect while preserving disease information. Protocol-specific w-score standardization effectively resolved the concerns of conventional regression methods. It showed the best performance for improving the compatibility of a T1 MR post-processed feature, cortical thickness. Copyright © 2017 Elsevier Inc. All rights reserved.
Optimized Setup and Protocol for Magnetic Domain Imaging with In Situ Hysteresis Measurement.
Liu, Jun; Wilson, John; Davis, Claire; Peyton, Anthony
2017-11-07
This paper elaborates the sample preparation protocols required to obtain optimal domain patterns using the Bitter method, focusing on the extra steps compared to standard metallographic sample preparation procedures. The paper proposes a novel bespoke rig for dynamic domain imaging with in situ BH (magnetic hysteresis) measurements and elaborates the protocols for the sensor preparation and the use of the rig to ensure accurate BH measurement. The protocols for static and ordinary dynamic domain imaging (without in situ BH measurements) are also presented. The reported method takes advantage of the convenience and high sensitivity of the traditional Bitter method and enables in situ BH measurement without interrupting or interfering with the domain wall movement processes. This facilitates establishing a direct and quantitative link between the domain wall movement processes-microstructural feature interactions in ferritic steels with their BH loops. This method is anticipated to become a useful tool for the fundamental study of microstructure-magnetic property relationships in steels and to help interpret the electromagnetic sensor signals for non-destructive evaluation of steel microstructures.
Optimized Setup and Protocol for Magnetic Domain Imaging with In Situ Hysteresis Measurement
Liu, Jun; Wilson, John; Davis, Claire; Peyton, Anthony
2017-01-01
This paper elaborates the sample preparation protocols required to obtain optimal domain patterns using the Bitter method, focusing on the extra steps compared to standard metallographic sample preparation procedures. The paper proposes a novel bespoke rig for dynamic domain imaging with in situ BH (magnetic hysteresis) measurements and elaborates the protocols for the sensor preparation and the use of the rig to ensure accurate BH measurement. The protocols for static and ordinary dynamic domain imaging (without in situ BH measurements) are also presented. The reported method takes advantage of the convenience and high sensitivity of the traditional Bitter method and enables in situ BH measurement without interrupting or interfering with the domain wall movement processes. This facilitates establishing a direct and quantitative link between the domain wall movement processes–microstructural feature interactions in ferritic steels with their BH loops. This method is anticipated to become a useful tool for the fundamental study of microstructure–magnetic property relationships in steels and to help interpret the electromagnetic sensor signals for non-destructive evaluation of steel microstructures. PMID:29155796
Evaluation of Aspergillus PCR protocols for testing serum specimens.
White, P Lewis; Mengoli, Carlo; Bretagne, Stéphane; Cuenca-Estrella, Manuel; Finnstrom, Niklas; Klingspor, Lena; Melchers, Willem J G; McCulloch, Elaine; Barnes, Rosemary A; Donnelly, J Peter; Loeffler, Juergen
2011-11-01
A panel of human serum samples spiked with various amounts of Aspergillus fumigatus genomic DNA was distributed to 23 centers within the European Aspergillus PCR Initiative to determine analytical performance of PCR. Information regarding specific methodological components and PCR performance was requested. The information provided was made anonymous, and meta-regression analysis was performed to determine any procedural factors that significantly altered PCR performance. Ninety-seven percent of protocols were able to detect a threshold of 10 genomes/ml on at least one occasion, with 83% of protocols reproducibly detecting this concentration. Sensitivity and specificity were 86.1% and 93.6%, respectively. Positive associations between sensitivity and the use of larger sample volumes, an internal control PCR, and PCR targeting the internal transcribed spacer (ITS) region were shown. Negative associations between sensitivity and the use of larger elution volumes (≥100 μl) and PCR targeting the mitochondrial genes were demonstrated. Most Aspergillus PCR protocols used to test serum generate satisfactory analytical performance. Testing serum requires less standardization, and the specific recommendations shown in this article will only improve performance.
Evaluation of Aspergillus PCR Protocols for Testing Serum Specimens▿†
White, P. Lewis; Mengoli, Carlo; Bretagne, Stéphane; Cuenca-Estrella, Manuel; Finnstrom, Niklas; Klingspor, Lena; Melchers, Willem J. G.; McCulloch, Elaine; Barnes, Rosemary A.; Donnelly, J. Peter; Loeffler, Juergen
2011-01-01
A panel of human serum samples spiked with various amounts of Aspergillus fumigatus genomic DNA was distributed to 23 centers within the European Aspergillus PCR Initiative to determine analytical performance of PCR. Information regarding specific methodological components and PCR performance was requested. The information provided was made anonymous, and meta-regression analysis was performed to determine any procedural factors that significantly altered PCR performance. Ninety-seven percent of protocols were able to detect a threshold of 10 genomes/ml on at least one occasion, with 83% of protocols reproducibly detecting this concentration. Sensitivity and specificity were 86.1% and 93.6%, respectively. Positive associations between sensitivity and the use of larger sample volumes, an internal control PCR, and PCR targeting the internal transcribed spacer (ITS) region were shown. Negative associations between sensitivity and the use of larger elution volumes (≥100 μl) and PCR targeting the mitochondrial genes were demonstrated. Most Aspergillus PCR protocols used to test serum generate satisfactory analytical performance. Testing serum requires less standardization, and the specific recommendations shown in this article will only improve performance. PMID:21940479
Estimating dermal transfer from PCB-contaminated porous surfaces.
Slayton, T M; Valberg, P A; Wait, A D
1998-06-01
Health risks posed by dermal contact with PCB-contaminated porous surfaces have not been directly demonstrated and are difficult to estimate indirectly. Surface contamination by organic compounds is commonly assessed by collecting wipe samples with hexane as the solvent. However, for porous surfaces, hexane wipe characterization is of limited direct use when estimating potential human exposure. Particularly for porous surfaces, the relationship between the amount of organic material collected by hexane and the amount actually picked up by, for example, a person's hand touch is unknown. To better mimic PCB pickup by casual hand contact with contaminated concrete surfaces, we used alternate solvents and wipe application methods that more closely mimic casual dermal contact. Our sampling results were compared to PCB pickup using hexane-wetted wipes and the standard rubbing protocol. Dry and oil-wetted samples, applied without rubbing, picked up less than 1% of the PCBs picked up by the standard hexane procedure; with rubbing, they picked up about 2%. Without rubbing, saline-wetted wipes picked up 2.5%; with rubbing, they picked up about 12%. While the nature of dermal contact with a contaminated surface cannot be perfectly reproduced with a wipe sample, our results with alternate wiping solvents and rubbing methods more closely mimic hand contact than the standard hexane wipe protocol. The relative pickup estimates presented in this paper can be used in conjunction with site-specific PCB hexane wipe results to estimate dermal pickup rates at sites with PCB-contaminated concrete.
Murphy, Kathleen R.; Butler, Kenna D.; Spencer, Robert G. M.; Stedmon, Colin A.; Boehme, Jennifer R.; Aiken, George R.
2010-01-01
The fluorescent properties of dissolved organic matter (DOM) are often studied in order to infer DOM characteristics in aquatic environments, including source, quantity, composition, and behavior. While a potentially powerful technique, a single widely implemented standard method for correcting and presenting fluorescence measurements is lacking, leading to difficulties when comparing data collected by different research groups. This paper reports on a large-scale interlaboratory comparison in which natural samples and well-characterized fluorophores were analyzed in 20 laboratories in the U.S., Europe, and Australia. Shortcomings were evident in several areas, including data quality-assurance, the accuracy of spectral correction factors used to correct EEMs, and the treatment of optically dense samples. Data corrected by participants according to individual laboratory procedures were more variable than when corrected under a standard protocol. Wavelength dependency in measurement precision and accuracy were observed within and between instruments, even in corrected data. In an effort to reduce future occurrences of similar problems, algorithms for correcting and calibrating EEMs are described in detail, and MATLAB scripts for implementing the study's protocol are provided. Combined with the recent expansion of spectral fluorescence standards, this approach will serve to increase the intercomparability of DOM fluorescence studies.
The predictive value of skin prick testing for challenge-proven food allergy: a systematic review.
Peters, Rachel L; Gurrin, Lyle C; Allen, Katrina J
2012-06-01
Immunoglobulin E-mediated (IgE) food allergy affects 6-8% of children, and the prevalence is believed to be increasing. The gold standard of food allergy diagnosis is oral food challenges (OFCs); however, they are resource-consuming and potentially dangerous. Skin prick tests (SPTs) are able to detect the presence of allergen-specific IgE antibodies (sensitization), but they have low specificity for clinically significant food allergy. To reduce the need for OFCs, it has been suggested that children forgo an OFC if their SPT wheal size exceeds a cutoff that has a high predictability for food allergy. Although data for these studies are almost always gathered from high-risk populations, the 95% positive predictive values (PPVs) vary substantially between studies. SPT thresholds with a high probability of food allergy generated from these studies may not be generalizable to other populations, because of highly selective samples and variability in participant's age, test allergens, and food challenge protocol. Standardization of SPT devices and allergens, OFC protocols including standardized cessation criteria, and population-based samples would all help to improve generalizability of PPVs of SPTs. © 2011 John Wiley & Sons A/S.
Unice, Kenneth M.; Kreider, Marisa L.; Panko, Julie M.
2012-01-01
Pyrolysis(pyr)-GC/MS analysis of characteristic thermal decomposition fragments has been previously used for qualitative fingerprinting of organic sources in environmental samples. A quantitative pyr-GC/MS method based on characteristic tire polymer pyrolysis products was developed for tread particle quantification in environmental matrices including soil, sediment, and air. The feasibility of quantitative pyr-GC/MS analysis of tread was confirmed in a method evaluation study using artificial soil spiked with known amounts of cryogenically generated tread. Tread concentration determined by blinded analyses was highly correlated (r2 ≥ 0.88) with the known tread spike concentration. Two critical refinements to the initial pyrolysis protocol were identified including use of an internal standard and quantification by the dimeric markers vinylcyclohexene and dipentene, which have good specificity for rubber polymer with no other appreciable environmental sources. A novel use of deuterated internal standards of similar polymeric structure was developed to correct the variable analyte recovery caused by sample size, matrix effects, and ion source variability. The resultant quantitative pyr-GC/MS protocol is reliable and transferable between laboratories. PMID:23202830
Leeper-Majors, Kristine; Veale, James R; Westbrook, Thomas S; Reed, Kendall
2003-01-01
The purpose of this pilot study was to determine the effectiveness of using feedback from a standardized patient (SP) to teach a surgical resident (SR) informed consent (IC) protocol. Four general case types of increasing difficulty were tested in a longitudinal experimental design format. The four types of cases were appendectomy, cholecystectomy, colorectal cancer, and breast cancer. Eight SRs of varying years of completion in medical school served as subjects-four in the experimental group (received performance feedback from an SP) and four in the control group (received no SP feedback). Both the control and experimental groups participated in two patient encounters per case type. The first patient encounter served as the pretest, and the second patient encounter was the posttest. In each encounter, an SP rated the resident on 14 measures using an open-ended seven-point rating scale adopted and modified from the Brown University Interpersonal Skill Evaluation (BUISE). Each resident also reviewed a videotape of an expert giving IC between pretest and the posttest for basic instructional protocol. Random stratified sampling was used to equally distribute the residents by postgraduate years. A total of 16 SPs were used in this study. All patient/SR encounters were videotaped. There was a statistically significant overall change--pretest to posttest and across cases (p = 0.001). The group effect was statistically significant (p = 0.000), with the experimental group averaging about 10 points greater than the control group. Standardized patient feedback is an effective modality in teaching surgical residents informed consent protocol. This conclusion is tentative, due to the limitations of sample size. The results of this study support continued research on the effects of standardized patient feedback to teach informed consent to surgical residents.
Kalina, Tomas; Flores-Montero, Juan; Lecrevisse, Quentin; Pedreira, Carlos E; van der Velden, Vincent H J; Novakova, Michaela; Mejstrikova, Ester; Hrusak, Ondrej; Böttcher, Sebastian; Karsch, Dennis; Sędek, Łukasz; Trinquand, Amelie; Boeckx, Nancy; Caetano, Joana; Asnafi, Vahid; Lucio, Paulo; Lima, Margarida; Helena Santos, Ana; Bonaccorso, Paola; van der Sluijs-Gelling, Alita J; Langerak, Anton W; Martin-Ayuso, Marta; Szczepański, Tomasz; van Dongen, Jacques J M; Orfao, Alberto
2015-02-01
Flow cytometric immunophenotyping has become essential for accurate diagnosis, classification, and disease monitoring in hemato-oncology. The EuroFlow Consortium has established a fully standardized "all-in-one" pipeline consisting of standardized instrument settings, reagent panels, and sample preparation protocols and software for data analysis and disease classification. For its reproducible implementation, parallel development of a quality assurance (QA) program was required. Here, we report on the results of four consecutive annual rounds of the novel external QA EuroFlow program. The novel QA scheme aimed at monitoring the whole flow cytometric analysis process (cytometer setting, sample preparation, acquisition and analysis) by reading the median fluorescence intensities (MedFI) of defined lymphocytes' subsets. Each QA participant applied the predefined reagents' panel on blood cells of local healthy donors. A uniform gating strategy was applied to define lymphocyte subsets and to read MedFI values per marker. The MedFI values were compared with reference data and deviations from reference values were quantified using performance score metrics. In four annual QA rounds, we analyzed 123 blood samples from local healthy donors on 14 different instruments in 11 laboratories from nine European countries. The immunophenotype of defined cellular subsets appeared sufficiently standardized to permit unified (software) data analysis. The coefficient of variation of MedFI for 7 of 11 markers performed repeatedly below 30%, average MedFI in each QA round ranged from 86 to 125% from overall median. Calculation of performance scores was instrumental to pinpoint standardization failures and their causes. Overall, the new EuroFlow QA system for the first time allowed to quantify the technical variation that is introduced in the measurement of fluorescence intensities in a multicentric setting over an extended period of time. EuroFlow QA is a proficiency test specific for laboratories that use standardized EuroFlow protocols. It may be used to complement, but not replace, established proficiency tests. © 2014 International Society for Advancement of Cytometry. © 2014 International Society for Advancement of Cytometry.
Cruz, Cristina D; Win, Jessicah K; Chantarachoti, Jiraporn; Mutukumira, Anthony N; Fletcher, Graham C
2012-02-15
The standard Bacteriological Analytical Manual (BAM) protocol for detecting Listeria in food and on environmental surfaces takes about 96 h. Some studies indicate that rapid methods, which produce results within 48 h, may be as sensitive and accurate as the culture protocol. As they only give presence/absence results, it can be difficult to compare the accuracy of results generated. We used the Most Probable Number (MPN) technique to evaluate the performance and detection limits of six rapid kits for detecting Listeria in seafood and on an environmental surface compared with the standard protocol. Three seafood products and an environmental surface were inoculated with similar known cell concentrations of Listeria and analyzed according to the manufacturers' instructions. The MPN was estimated using the MPN-BAM spreadsheet. For the seafood products no differences were observed among the rapid kits and efficiency was similar to the BAM method. On the environmental surface the BAM protocol had a higher recovery rate (sensitivity) than any of the rapid kits tested. Clearview™, Reveal®, TECRA® and VIDAS® LDUO detected the cells but only at high concentrations (>10(2) CFU/10 cm(2)). Two kits (VIP™ and Petrifilm™) failed to detect 10(4) CFU/10 cm(2). The MPN method was a useful tool for comparing the results generated by these presence/absence test kits. There remains a need to develop a rapid and sensitive method for detecting Listeria in environmental samples that performs as well as the BAM protocol, since none of the rapid tests used in this study achieved a satisfactory result. Copyright © 2011 Elsevier B.V. All rights reserved.
The potential for error in sampling
Jack Lewis
2000-01-01
Editor's note: The measurement of water quality parameters in environmental laboratories follows standard quality control protocols using methodologies approved by the U.S. Environmental Protection Agency. However, little attention has been given to quality assurance and quality control in activities outside the laboratory. This article describes some of those...
Cost-effectiveness of risk stratified followup after urethral reconstruction: a decision analysis.
Belsante, Michael J; Zhao, Lee C; Hudak, Steven J; Lotan, Yair; Morey, Allen F
2013-10-01
We propose a novel risk stratified followup protocol for use after urethroplasty and explore potential cost savings. Decision analysis was performed comparing a symptom based, risk stratified protocol for patients undergoing excision and primary anastomosis urethroplasty vs a standard regimen of close followup for urethroplasty. Model assumptions included that excision and primary anastomosis has a 94% success rate, 11% of patients with successful urethroplasty had persistent lower urinary tract symptoms requiring cystoscopic evaluation, patients in whom treatment failed undergo urethrotomy and patients with recurrence on symptom based surveillance have a delayed diagnosis requiring suprapubic tube drainage. The Nationwide Inpatient Sample from 2010 was queried to identify the number of urethroplasties performed per year in the United States. Costs were obtained based on Medicare reimbursement rates. The 5-year cost of a symptom based, risk stratified followup protocol is $430 per patient vs $2,827 per patient using standard close followup practice. An estimated 7,761 urethroplasties were performed in the United States in 2010. Assuming that 60% were excision and primary anastomosis, and with more than 5 years of followup, the risk stratified protocol was projected to yield an estimated savings of $11,165,130. Sensitivity analysis showed that the symptom based, risk stratified followup protocol was far more cost-effective than standard close followup in all settings. Less than 1% of patients would be expected to have an asymptomatic recurrence using the risk stratified followup protocol. A risk stratified, symptom based approach to urethroplasty followup would produce a significant reduction in health care costs while decreasing unnecessary followup visits, invasive testing and radiation exposure. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Matrone, M.; Keid, L.B.; Rocha, V.C.M.; Vejarano, M.P.; Ikuta, C.Y.; Rodriguez, C.A.R.; Ferreira, F.; Dias, R.A.; Ferreira Neto, J.S
2009-01-01
The objective of the present study was to improve the detection of B. abortus by PCR in organs of aborted fetuses from infected cows, an important mechanism to find infected herds on the eradication phase of the program. So, different DNA extraction protocols were compared, focusing the PCR detection of B. abortus in clinical samples collected from aborted fetuses or calves born from cows challenged with the 2308 B. abortus strain. Therefore, two gold standard groups were built based on classical bacteriology, formed from: 32 lungs (17 positives), 26 spleens (11 positives), 23 livers (8 positives) and 22 bronchial lymph nodes (7 positives). All samples were submitted to three DNA extraction protocols, followed by the same amplification process with the primers B4 and B5. From the accumulated results for organ, the proportion of positives for the lungs was higher than the livers (p=0.04) or bronchial lymph nodes (p=0.004) and equal to the spleens (p=0.18). From the accumulated results for DNA extraction protocol, the proportion of positives for the Boom protocol was bigger than the PK (p< 0.0001) and GT (p=0.0004). There was no difference between the PK and GT protocols (p=0.5). Some positive samples from the classical bacteriology were negative to the PCR and vice-versa. Therefore, the best strategy for B. abortus detection in the organs of aborted fetuses or calves born from infected cows is the use, in parallel, of isolation by classical bacteriology and the PCR, with the DNA extraction performed by the Boom protocol. PMID:24031391
Rasmussen, Stinne Eika; Nebsbjerg, Mette Amalie; Krogh, Lise Qvirin; Bjørnshave, Katrine; Krogh, Kristian; Povlsen, Jonas Agerlund; Riddervold, Ingunn Skogstad; Grøfte, Thorbjørn; Kirkegaard, Hans; Løfgren, Bo
2017-01-01
Emergency dispatchers use protocols to instruct bystanders in cardiopulmonary resuscitation (CPR). Studies changing one element in the dispatcher's protocol report improved CPR quality. Whether several changes interact is unknown and the effect of combining multiple changes previously reported to improve CPR quality into one protocol remains to be investigated. We hypothesize that a novel dispatch protocol, combining multiple beneficial elements improves CPR quality compared with a standard protocol. A novel dispatch protocol was designed including wording on chest compressions, using a metronome, regular encouragements and a 10-s rest each minute. In a simulated cardiac arrest scenario, laypersons were randomized to perform single-rescuer CPR guided with the novel or the standard protocol. a composite endpoint of time to first compression, hand position, compression depth and rate and hands-off time (maximum score: 22 points). Afterwards participants answered a questionnaire evaluating the dispatcher assistance. The novel protocol (n=61) improved CPR quality score compared with the standard protocol (n=64) (mean (SD): 18.6 (1.4)) points vs. 17.5 (1.7) points, p<0.001. The novel protocol resulted in deeper chest compressions (mean (SD): 58 (12)mm vs. 52 (13)mm, p=0.02) and improved rate of correct hand position (61% vs. 36%, p=0.01) compared with the standard protocol. In both protocols hands-off time was short. The novel protocol improved motivation among rescuers compared with the standard protocol (p=0.002). Participants guided with a standard dispatch protocol performed high quality CPR. A novel bundle of care protocol improved CPR quality score and motivation among rescuers. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
A standardized sampling protocol for channel catfish in prairie streams
Vokoun, Jason C.; Rabeni, Charles F.
2001-01-01
Three alternative gears—an AC electrofishing raft, bankpoles, and a 15-hoop-net set—were used in a standardized manner to sample channel catfish Ictalurus punctatus in three prairie streams of varying size in three seasons. We compared these gears as to time required per sample, size selectivity, mean catch per unit effort (CPUE) among months, mean CPUE within months, effect of fluctuating stream stage, and sensitivity to population size. According to these comparisons, the 15-hoop-net set used during stable water levels in October had the most desirable characteristics. Using our catch data, we estimated the precision of CPUE and size structure by varying sample sizes for the 15-hoop-net set. We recommend that 11–15 repetitions of the 15-hoop-net set be used for most management activities. This standardized basic unit of effort will increase the precision of estimates and allow better comparisons among samples as well as increased confidence in management decisions.
DNA origami-based standards for quantitative fluorescence microscopy.
Schmied, Jürgen J; Raab, Mario; Forthmann, Carsten; Pibiri, Enrico; Wünsch, Bettina; Dammeyer, Thorben; Tinnefeld, Philip
2014-01-01
Validating and testing a fluorescence microscope or a microscopy method requires defined samples that can be used as standards. DNA origami is a new tool that provides a framework to place defined numbers of small molecules such as fluorescent dyes or proteins in a programmed geometry with nanometer precision. The flexibility and versatility in the design of DNA origami microscopy standards makes them ideally suited for the broad variety of emerging super-resolution microscopy methods. As DNA origami structures are durable and portable, they can become a universally available specimen to check the everyday functionality of a microscope. The standards are immobilized on a glass slide, and they can be imaged without further preparation and can be stored for up to 6 months. We describe a detailed protocol for the design, production and use of DNA origami microscopy standards, and we introduce a DNA origami rectangle, bundles and a nanopillar as fluorescent nanoscopic rulers. The protocol provides procedures for the design and realization of fluorescent marks on DNA origami structures, their production and purification, quality control, handling, immobilization, measurement and data analysis. The procedure can be completed in 1-2 d.
Saracevic, Andrea; Simundic, Ana-Maria; Celap, Ivana; Luzanic, Valentina
2013-07-01
Rigat and colleagues were the first ones to develop a rapid PCR-based assay for identifying the angiotensin converting enzyme insertion/deletion (I/D) polymorphism. Due to a big difference between the length of the wild-type and mute alleles the PCR method is prone to mistyping because of preferential amplification of the D allele causing depicting I/D heterozygotes as D/D homozygotes. The aim of this study was to investigate whether this preferential amplification can be repressed by amplifying a longer DNA fragment in a so called Long PCR protocol. We also aimed to compare the results of genotyping using five different PCR protocols and to estimate the mistyping rate. The study included 200 samples which were genotyped using standard method used in our laboratory, a stepdown PCR, PCR protocol with the inclusion of 4 % DMSO, PCR with the use of insertion specific primers and new Long PCR method. The results of this study have shown that accurate ACE I/D polymorphism genotyping can be accomplished with the standard and the Long PCR method. Also, as of our results, accurate ACE I/D polymorphism genotyping can be accomplished regardless of the method used. Therefore, if the standard method is optimized more cautiously, accurate results can be obtained by this simple, inexpensive and rapid PCR protocol.
EDRN Standard Operating Procedures (SOP) — EDRN Public Portal
The NCI’s Early Detection Research Network is developing a number of standard operating procedures for assays, methods, and protocols for collection and processing of biological samples, and other reference materials to assist investigators to conduct experiments in a consistent, reliable manner. These SOPs are established by the investigators of the Early Detection Research Network to maintain constancy throughout the Network. These SOPs represent neither a consensus, nor are the recommendations of NCI.
Tallarico, Lenita de Freitas; Borrely, Sueli Ivone; Hamada, Natália; Grazeffe, Vanessa Siqueira; Ohlweiler, Fernanda Pires; Okazaki, Kayo; Granatelli, Amanda Tosatte; Pereira, Ivana Wuo; Pereira, Carlos Alberto de Bragança; Nakano, Eliana
2014-12-01
A protocol combining acute toxicity, developmental toxicity and mutagenicity analysis in freshwater snail Biomphalaria glabrata for application in ecotoxicological studies is described. For acute toxicity testing, LC50 and EC50 values were determined; dominant lethal mutations induction was the endpoint for mutagenicity analysis. Reference toxicant potassium dichromate (K2Cr2O7) was used to characterize B. glabrata sensitivity for toxicity and cyclophosphamide to mutagenicity testing purposes. Compared to other relevant freshwater species, B. glabrata showed high sensitivity: the lowest EC50 value was obtained with embryos at veliger stage (5.76mg/L). To assess the model applicability for environmental studies, influent and effluent water samples from a wastewater treatment plant were evaluated. Gastropod sensitivity was assessed in comparison to the standardized bioassay with Daphnia similis exposed to the same water samples. Sampling sites identified as toxic to daphnids were also detected by snails, showing a qualitatively similar sensitivity suggesting that B. glabrata is a suitable test species for freshwater monitoring. Holding procedures and protocols implemented for toxicity and developmental bioassays showed to be in compliance with international standards for intra-laboratory precision. Thereby, we are proposing this system for application in ecotoxicological studies. Copyright © 2014 Elsevier Inc. All rights reserved.
Microfluidic, marker-free isolation of circulating tumor cells from blood samples
Karabacak, Nezihi Murat; Spuhler, Philipp S; Fachin, Fabio; Lim, Eugene J; Pai, Vincent; Ozkumur, Emre; Martel, Joseph M; Kojic, Nikola; Smith, Kyle; Chen, Pin-i; Yang, Jennifer; Hwang, Henry; Morgan, Bailey; Trautwein, Julie; Barber, Thomas A; Stott, Shannon L; Maheswaran, Shyamala; Kapur, Ravi; Haber, Daniel A; Toner, Mehmet
2014-01-01
The ability to isolate and analyze rare circulating tumor cells (CTCs) has the potential to further our understanding of cancer metastasis and enhance the care of cancer patients. In this protocol, we describe the procedure for isolating rare CTCs from blood samples by using tumor antigen–independent microfluidic CTC-iChip technology. The CTC-iChip uses deterministic lateral displacement, inertial focusing and magnetophoresis to sort up to 107 cells/s. By using two-stage magnetophoresis and depletion antibodies against leukocytes, we achieve 3.8-log depletion of white blood cells and a 97% yield of rare cells with a sample processing rate of 8 ml of whole blood/h. The CTC-iChip is compatible with standard cytopathological and RNA-based characterization methods. This protocol describes device production, assembly, blood sample preparation, system setup and the CTC isolation process. Sorting 8 ml of blood sample requires 2 h including setup time, and chip production requires 2–5 d. PMID:24577360
Pre-capture multiplexing improves efficiency and cost-effectiveness of targeted genomic enrichment.
Shearer, A Eliot; Hildebrand, Michael S; Ravi, Harini; Joshi, Swati; Guiffre, Angelica C; Novak, Barbara; Happe, Scott; LeProust, Emily M; Smith, Richard J H
2012-11-14
Targeted genomic enrichment (TGE) is a widely used method for isolating and enriching specific genomic regions prior to massively parallel sequencing. To make effective use of sequencer output, barcoding and sample pooling (multiplexing) after TGE and prior to sequencing (post-capture multiplexing) has become routine. While previous reports have indicated that multiplexing prior to capture (pre-capture multiplexing) is feasible, no thorough examination of the effect of this method has been completed on a large number of samples. Here we compare standard post-capture TGE to two levels of pre-capture multiplexing: 12 or 16 samples per pool. We evaluated these methods using standard TGE metrics and determined the ability to identify several classes of genetic mutations in three sets of 96 samples, including 48 controls. Our overall goal was to maximize cost reduction and minimize experimental time while maintaining a high percentage of reads on target and a high depth of coverage at thresholds required for variant detection. We adapted the standard post-capture TGE method for pre-capture TGE with several protocol modifications, including redesign of blocking oligonucleotides and optimization of enzymatic and amplification steps. Pre-capture multiplexing reduced costs for TGE by at least 38% and significantly reduced hands-on time during the TGE protocol. We found that pre-capture multiplexing reduced capture efficiency by 23 or 31% for pre-capture pools of 12 and 16, respectively. However efficiency losses at this step can be compensated by reducing the number of simultaneously sequenced samples. Pre-capture multiplexing and post-capture TGE performed similarly with respect to variant detection of positive control mutations. In addition, we detected no instances of sample switching due to aberrant barcode identification. Pre-capture multiplexing improves efficiency of TGE experiments with respect to hands-on time and reagent use compared to standard post-capture TGE. A decrease in capture efficiency is observed when using pre-capture multiplexing; however, it does not negatively impact variant detection and can be accommodated by the experimental design.
Experimental Demonstration of a Cheap and Accurate Phase Estimation
Rudinger, Kenneth; Kimmel, Shelby; Lobser, Daniel; ...
2017-05-11
We demonstrate an experimental implementation of robust phase estimation (RPE) to learn the phase of a single-qubit rotation on a trapped Yb + ion qubit. Here, we show this phase can be estimated with an uncertainty below 4 × 10 -4 rad using as few as 176 total experimental samples, and our estimates exhibit Heisenberg scaling. Unlike standard phase estimation protocols, RPE neither assumes perfect state preparation and measurement, nor requires access to ancillae. We crossvalidate the results of RPE with the more resource-intensive protocol of gate set tomography.
Herruzo, R; Vizcaino, M J; Yela, R
2018-04-01
Surgical use of 4% chlorhexidine soap (CHX-4) and 10% povidone iodine (PVP-I-10) does not meet the standards defined by EN 12791. To investigate the possibility of increasing the immediate and residual effects of these antiseptics. Over three consecutive weeks, n-propanol, standard CHX-4 and PVP-I-10 were tested in two experimental groups of volunteers. The new method for applying the antiseptic substances involved standard hand rub and rinse of CHX-4 or PVP-I-10, followed by application of an aqueous solution based on 5% chlorhexidine or PVP-I-10 with no further rinsing of the hands prior to donning gloves. Samples were taken to assess immediate and residual effects, analysing the logarithmic reduction of colony-forming units. At t=0 h, n-propanol was superior in bactericidal effect to standard CHX-4 (P<0.05), but the new chlorhexidine protocol was superior to both standard CHX-4 (P<0.01) and n-propanol (P<0.05); the same effect was observed at t=3 h (residual effect). At t=0 h, n-propanol was significantly superior to standard PVP-I-10, but the new PVP-I-10 protocol was superior, although not significantly, to n-propanol. There was no significant residual effect at t=3 h. The new protocol for chlorhexidine application permits surgical hand preparation with chlorhexidine, as a safe alternative to alcohol solutions, because it meets the standards defined by EN 12791. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
VALIDATION OF STANDARD ANALYTICAL PROTOCOL FOR ...
There is a growing concern with the potential for terrorist use of chemical weapons to cause civilian harm. In the event of an actual or suspected outdoor release of chemically hazardous material in a large area, the extent of contamination must be determined. This requires a system with the ability to prepare and quickly analyze a large number of contaminated samples for the traditional chemical agents, as well as numerous toxic industrial chemicals. Liquid samples (both aqueous and organic), solid samples (e.g., soil), vapor samples (e.g., air) and mixed state samples, all ranging from household items to deceased animals, may require some level of analyses. To meet this challenge, the U.S. Environmental Protection Agency (U.S. EPA) National Homeland Security Research Center, in collaboration with experts from across U.S. EPA and other Federal Agencies, initiated an effort to identify analytical methods for the chemical and biological agents that could be used to respond to a terrorist attack or a homeland security incident. U.S. EPA began development of standard analytical protocols (SAPs) for laboratory identification and measurement of target agents in case of a contamination threat. These methods will be used to help assist in the identification of existing contamination, the effectiveness of decontamination, as well as clearance for the affected population to reoccupy previously contaminated areas. One of the first SAPs developed was for the determin
López, Luisa F; Muñoz, César O; Cáceres, Diego H; Tobón, Ángela M; Loparev, Vladimir; Clay, Oliver; Chiller, Tom; Litvintseva, Anastasia; Gade, Lalitha; González, Ángel; Gómez, Beatriz L
2017-01-01
Histoplasmosis is considered one of the most important endemic and systemic mycoses worldwide. Until now few molecular techniques have been developed for its diagnosis. The aim of this study was to develop and evaluate three real time PCR (qPCR) protocols for different protein-coding genes (100-kDa, H and M antigens) using an animal model. Fresh and formalin-fixed and paraffin-embedded (FFPE) lung tissues from BALB/c mice inoculated i.n. with 2.5x106 Histoplasma capsulatum yeast or PBS were obtained at 1, 2, 3, 4, 8, 12 and 16 weeks post-infection. A collection of DNA from cultures representing different clades of H. capsulatum (30 strains) and other medically relevant pathogens (36 strains of related fungi and Mycobacterium tuberculosis) were used to analyze sensitivity and specificity. Analytical sensitivity and specificity were 100% when DNAs from the different strains were tested. The highest fungal burden occurred at first week post-infection and complete fungal clearance was observed after the third week; similar results were obtained when the presence of H. capsulatum yeast cells was demonstrated in histopathological analysis. In the first week post-infection, all fresh and FFPE lung tissues from H. capsulatum-infected animals were positive for the qPCR protocols tested except for the M antigen protocol, which gave variable results when fresh lung tissue samples were analyzed. In the second week, all qPCR protocols showed variable results for both fresh and FFPE tissues. Samples from the infected mice at the remaining times post-infection and uninfected mice (controls) were negative for all protocols. Good agreement was observed between CFUs, histopathological analysis and qPCR results for the 100-kDa and H antigen protocols. We successfully standardized and validated three qPCR assays for detecting H. capsulatum DNA in fresh and FFPE tissues, and conclude that the 100-kDa and H antigen molecular assays are promising tests for diagnosing this mycosis.
Profeta, Gerson S.; Pereira, Jessica A. S.; Costa, Samara G.; Azambuja, Patricia; Garcia, Eloi S.; Moraes, Caroline da Silva; Genta, Fernando A.
2017-01-01
Glycoside Hydrolases (GHs) are enzymes able to recognize and cleave glycosidic bonds. Insect GHs play decisive roles in digestion, in plant-herbivore, and host-pathogen interactions. GH activity is normally measured by the detection of a release from the substrate of products as sugars units, colored, or fluorescent groups. In most cases, the conditions for product release and detection differ, resulting in discontinuous assays. The current protocols result in using large amounts of reaction mixtures for the obtainment of time points in each experimental replica. These procedures restrain the analysis of biological materials with limited amounts of protein and, in the case of studies regarding small insects, implies in the pooling of samples from several individuals. In this respect, most studies do not assess the variability of GH activities across the population of individuals from the same species. The aim of this work is to approach this technical problem and have a deeper understanding of the variation of GH activities in insect populations, using as models the disease vectors Rhodnius prolixus (Hemiptera: Triatominae) and Lutzomyia longipalpis (Diptera: Phlebotominae). Here we standardized continuous assays using 4-methylumbelliferyl derived substrates for the detection of α-Glucosidase, β-Glucosidase, α-Mannosidase, N-acetyl-hexosaminidase, β-Galactosidase, and α-Fucosidase in the midgut of R. prolixus and L. longipalpis with results similar to the traditional discontinuous protocol. The continuous assays allowed us to measure GH activities using minimal sample amounts with a higher number of measurements, resulting in data that are more reliable and less time and reagent consumption. The continuous assay also allows the high-throughput screening of GH activities in small insect samples, which would be not applicable to the previous discontinuous protocol. We applied continuous GH measurements to 90 individual samples of R. prolixus anterior midgut homogenates using a high-throughput protocol. α-Glucosidase and α-Mannosidase activities showed the normal distribution in the population. β-Glucosidase, β-Galactosidase, N-acetyl-hexosaminidase, and α-Fucosidase activities showed non-normal distributions. These results indicate that GHs fluorescent-based high-throughput assays apply to insect samples and that the frequency distribution of digestive activities should be considered in data analysis, especially if a small number of samples is used. PMID:28553236
Seebeck Coefficient Metrology: Do Contemporary Protocols Measure Up?
NASA Astrophysics Data System (ADS)
Martin, Joshua; Wong-Ng, Winnie; Green, Martin L.
2015-06-01
Comparative measurements of the Seebeck coefficient are challenging due to the diversity of instrumentation and measurement protocols. With the implementation of standardized measurement protocols and the use of Standard Reference Materials (SRMs®), for example, the recently certified National Institute of Standards and Technology (NIST) SRM® 3451 ``Low Temperature Seebeck Coefficient Standard (10-390 K)'', researchers can reliably analyze and compare data, both intra- and inter-laboratory, thereby accelerating the development of more efficient thermoelectric materials and devices. We present a comparative overview of commonly adopted Seebeck coefficient measurement practices. First, we examine the influence of asynchronous temporal and spatial measurement of electric potential and temperature. Temporal asynchronicity introduces error in the absolute Seebeck coefficient of the order of ≈10%, whereas spatial asynchronicity introduces error of the order of a few percent. Second, we examine the influence of poor thermal contact between the measurement probes and the sample. This is especially critical at high temperature, wherein the prevalent mode of measuring surface temperature is facilitated by pressure contact. Each topic will include the comparison of data measured using different measurement techniques and using different probe arrangements. We demonstrate that the probe arrangement is the primary limit to high accuracy, wherein the Seebeck coefficients measured by the 2-probe arrangement and those measured by the 4-probe arrangement diverge with the increase in temperature, approaching ≈14% at 900 K. Using these analyses, we provide recommended measurement protocols to guide members of the thermoelectric materials community in performing more accurate measurements and in evaluating more comprehensive uncertainty limits.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-10-01
General Atomics (GA) leads a team of industrial, academic, and government organizations to develop the Environmental Systems Management, Analysis and Reporting neTwork (E-SMART) for the Defense Advanced Research Project Agency (DARPA), by way of this Technology Reinvestment Project (TRP). E-SMART defines a standard by which networks of smart sensing, sampling, and control devices can interoperate. E-SMART is intended to be an open standard, available to any equipment manufacturer. The user will be provided a standard platform on which a site-specific monitoring plan can be implemented using sensors and actuators from various manufacturers and upgraded as new monitoring devices become commerciallymore » available. This project will further develop and advance the E-SMART standardized network protocol to include new sensors, sampling systems, and graphical user interfaces.« less
NASA Astrophysics Data System (ADS)
Preciado, C., Jr.
2016-12-01
Compound-specific stable isotope analysis (CSIA) has become a powerful tool for reconstructing consumer-resource relationships in modern and ancient systems. Stable nitrogen isotope analysis (δ15N) of "trophic" and "source" amino acids provides independent proxies of trophic position and the δ15N value at the base of the food web, respectively. When applied to avian egg tissues (e.g., shell protein, membrane), which can be preserved in the archaeological record, this approach can be used to address complex questions in food web architecture and biogeochemical cycling. In this study, we examined how sample-processing protocols affected the chromatography and reliability of δ15N values of individual amino acids in avian (chicken and penguin) egg components (shell protein, membrane, yolk, and albumen) via gas chromatography-combustion-isotope ratio mass spectrometry. "Unprocessed" egg tissues underwent standard acid hydrolysis protocols prior to derivatization, and resulted in poor chromatography with highly variable δ15N values across replicates. "Processed" samples were eluted through cation exchange columns (Dowex 50WX*400) prior to derivatization, followed by a P-buffer (KH2PO4 + Na2HPO4)-chloroform centrifugation extraction to remove confounding peaks and matrix impurities. These additional procedures greatly improved the chromatography of the "processed" samples, revealing better peak separation and baseline integration as well as lower δ15N variability. Additionally, a standard lipid extraction was necessary for yolk but not membrane, albumen, and shell. While the additional procedures applied to the "columned" samples did result in a significant reduction in sample yield ( 20%), it was non-fractionating and thus only affected the total sample sizes necessary for δ15N CSIA (shell protein 50mg and membrane, yolk, and albumen 0.5mg). The protocols developed here will streamline CSIA of egg tissues for future work in avian ecology.
Sayah, Anousheh; Jay, Ann K; Toaff, Jacob S; Makariou, Erini V; Berkowitz, Frank
2016-09-01
Reducing lumbar spine MRI scanning time while retaining diagnostic accuracy can benefit patients and reduce health care costs. This study compares the effectiveness of a rapid lumbar MRI protocol using 3D T2-weighted sampling perfection with application-optimized contrast with different flip-angle evolutions (SPACE) sequences with a standard MRI protocol for evaluation of lumbar spondylosis. Two hundred fifty consecutive unenhanced lumbar MRI examinations performed at 1.5 T were retrospectively reviewed. Full, rapid, and complete versions of each examination were interpreted for spondylotic changes at each lumbar level, including herniations and neural compromise. The full examination consisted of sagittal T1-weighted, T2-weighted turbo spin-echo (TSE), and STIR sequences; and axial T1- and T2-weighted TSE sequences (time, 18 minutes 40 seconds). The rapid examination consisted of sagittal T1- and T2-weighted SPACE sequences, with axial SPACE reformations (time, 8 minutes 46 seconds). The complete examination consisted of the full examination plus the T2-weighted SPACE sequence. Sensitivities and specificities of the full and rapid examinations were calculated using the complete study as the reference standard. The rapid and full studies had sensitivities of 76.0% and 69.3%, with specificities of 97.2% and 97.9%, respectively, for all degenerative processes. Rapid and full sensitivities were 68.7% and 66.3% for disk herniation, 85.2% and 81.5% for canal compromise, 82.9% and 69.1% for lateral recess compromise, and 76.9% and 69.7% for foraminal compromise, respectively. Isotropic SPACE T2-weighted imaging provides high-quality imaging of lumbar spondylosis, with multiplanar reformatting capability. Our SPACE-based rapid protocol had sensitivities and specificities for herniations and neural compromise comparable to those of the protocol without SPACE. This protocol fits within a 15-minute slot, potentially reducing costs and discomfort for a large subgroup of patients.
Sachs, Peter B; Hunt, Kelly; Mansoubi, Fabien; Borgstede, James
2017-02-01
Building and maintaining a comprehensive yet simple set of standardized protocols for a cross-sectional image can be a daunting task. A single department may have difficulty preventing "protocol creep," which almost inevitably occurs when an organized "playbook" of protocols does not exist and individual radiologists and technologists alter protocols at will and on a case-by-case basis. When multiple departments or groups function in a large health system, the lack of uniformity of protocols can increase exponentially. In 2012, the University of Colorado Hospital formed a large health system (UCHealth) and became a 5-hospital provider network. CT and MR imaging studies are conducted at multiple locations by different radiology groups. To facilitate consistency in ordering, acquisition, and appearance of a given study, regardless of location, we minimized the number of protocols across all scanners and sites of practice with a clinical indication-driven protocol selection and standardization process. Here we review the steps utilized to perform this process improvement task and insure its stability over time. Actions included creation of a standardized protocol template, which allowed for changes in electronic storage and management of protocols, designing a change request form, and formation of a governance structure. We utilized rapid improvement events (1 day for CT, 2 days for MR) and reduced 248 CT protocols into 97 standardized protocols and 168 MR protocols to 66. Additional steps are underway to further standardize output and reporting of imaging interpretation. This will result in an improved, consistent radiologist, patient, and provider experience across the system.
Chromatin Immunoprecipitation (ChIP) Protocol for Low-abundance Embryonic Samples.
Rehimi, Rizwan; Bartusel, Michaela; Solinas, Francesca; Altmüller, Janine; Rada-Iglesias, Alvaro
2017-08-29
Chromatin immunoprecipitation (ChIP) is a widely-used technique for mapping the localization of post-translationally modified histones, histone variants, transcription factors, or chromatin-modifying enzymes at a given locus or on a genome-wide scale. The combination of ChIP assays with next-generation sequencing (i.e., ChIP-Seq) is a powerful approach to globally uncover gene regulatory networks and to improve the functional annotation of genomes, especially of non-coding regulatory sequences. ChIP protocols normally require large amounts of cellular material, thus precluding the applicability of this method to investigating rare cell types or small tissue biopsies. In order to make the ChIP assay compatible with the amount of biological material that can typically be obtained in vivo during early vertebrate embryogenesis, we describe here a simplified ChIP protocol in which the number of steps required to complete the assay were reduced to minimize sample loss. This ChIP protocol has been successfully used to investigate different histone modifications in various embryonic chicken and adult mouse tissues using low to medium cell numbers (5 x 10 4 - 5 x 10 5 cells). Importantly, this protocol is compatible with ChIP-seq technology using standard library preparation methods, thus providing global epigenomic maps in highly relevant embryonic tissues.
Accuracy of the clinical diagnosis of vaginitis compared with a DNA probe laboratory standard.
Lowe, Nancy K; Neal, Jeremy L; Ryan-Wenger, Nancy A
2009-01-01
To estimate the accuracy of the clinical diagnosis of the three most common causes of acute vulvovaginal symptoms (bacterial vaginosis, candidiasis vaginitis, and trichomoniasis vaginalis) using a traditional, standardized clinical diagnostic protocol compared with a DNA probe laboratory standard. This prospective clinical comparative study had a sample of 535 active-duty United States military women presenting with vulvovaginal symptoms. Clinical diagnoses were made by research staff using a standardized protocol of history, physical examination including pelvic examination, determination of vaginal pH, vaginal fluid amines test, and wet-prep microscopy. Vaginal fluid samples were obtained for DNA analysis. The research clinicians were blinded to the DNA results. The participants described a presenting symptom of abnormal discharge (50%), itching/irritation (33%), malodor (10%), burning (4%), or others such as vulvar pain and vaginal discomfort. According to laboratory standard, there were 225 cases (42%) of bacterial vaginosis, 76 cases (14%) of candidiasis vaginitis, 8 cases (1.5%) of trichomoniasis vaginalis, 87 cases of mixed infections (16%), and 139 negative cases (26%). For each single infection, the clinical diagnosis had a sensitivity and specificity of 80.8% and 70.0% for bacterial vaginosis, 83.8% and 84.8% for candidiasis vaginitis, and 84.6% and 99.6% for trichomoniasis vaginalis when compared with the DNA probe standard. Compared with a DNA probe standard, clinical diagnosis is 81-85% sensitive and 70-99% specific for bacterial vaginosis, Candida vaginitis, and trichomoniasis. Even under research conditions that provided clinicians with sufficient time and materials to conduct a thorough and standardized clinical evaluation, the diagnosis and, therefore, subsequent treatment of these common vaginal problems remains difficult. II.
Recommendations for the use of mist nets for inventory and monitoring of bird populations
Ralph, C. John; Dunn, Erica H.; Peach, Will J.; Handel, Colleen M.; Ralph, C. John; Dunn, Erica H.
2004-01-01
We provide recommendations on the best practices for mist netting for the purposes of monitoring population parameters such as abundance and demography. Studies should be carefully thought out before nets are set up, to ensure that sampling design and estimated sample size will allow study objectives to be met. Station location, number of nets, type of nets, net placement, and schedule of operation should be determined by the goals of the particular project, and we provide guidelines for typical mist-net studies. In the absence of study-specific requirements for novel protocols, commonly used protocols should be used to enable comparison of results among studies. Regardless of the equipment, net layout, or netting schedule selected, it is important for all studies that operations be strictly standardized, and a well-written operation protocol will help in attaining this goal. We provide recommendations for data to be collected on captured birds, and emphasize the need for good training of project personnel
Optimizing fish sampling for fish - mercury bioaccumulation factors
Scudder Eikenberry, Barbara C.; Riva-Murray, Karen; Knightes, Christopher D.; Journey, Celeste A.; Chasar, Lia C.; Brigham, Mark E.; Bradley, Paul M.
2015-01-01
Fish Bioaccumulation Factors (BAFs; ratios of mercury (Hg) in fish (Hgfish) and water (Hgwater)) are used to develop Total Maximum Daily Load and water quality criteria for Hg-impaired waters. Both applications require representative Hgfish estimates and, thus, are sensitive to sampling and data-treatment methods. Data collected by fixed protocol from 11 streams in 5 states distributed across the US were used to assess the effects of Hgfish normalization/standardization methods and fish sample numbers on BAF estimates. Fish length, followed by weight, was most correlated to adult top-predator Hgfish. Site-specific BAFs based on length-normalized and standardized Hgfish estimates demonstrated up to 50% less variability than those based on non-normalized Hgfish. Permutation analysis indicated that length-normalized and standardized Hgfish estimates based on at least 8 trout or 5 bass resulted in mean Hgfish coefficients of variation less than 20%. These results are intended to support regulatory mercury monitoring and load-reduction program improvements.
Han, Yongming; Chen, Antony; Cao, Junji; Fung, Kochy; Ho, Fai; Yan, Beizhan; Zhan, Changlin; Liu, Suixin; Wei, Chong; An, Zhisheng
2013-01-01
Quantifying elemental carbon (EC) content in geological samples is challenging due to interferences of crustal, salt, and organic material. Thermal/optical analysis, combined with acid pretreatment, represents a feasible approach. However, the consistency of various thermal/optical analysis protocols for this type of samples has never been examined. In this study, urban street dust and soil samples from Baoji, China were pretreated with acids and analyzed with four thermal/optical protocols to investigate how analytical conditions and optical correction affect EC measurement. The EC values measured with reflectance correction (ECR) were found always higher and less sensitive to temperature program than the EC values measured with transmittance correction (ECT). A high-temperature method with extended heating times (STN120) showed the highest ECT/ECR ratio (0.86) while a low-temperature protocol (IMPROVE-550), with heating time adjusted for sample loading, showed the lowest (0.53). STN ECT was higher than IMPROVE ECT, in contrast to results from aerosol samples. A higher peak inert-mode temperature and extended heating times can elevate ECT/ECR ratios for pretreated geological samples by promoting pyrolyzed organic carbon (PyOC) removal over EC under trace levels of oxygen. Considering that PyOC within filter increases ECR while decreases ECT from the actual EC levels, simultaneous ECR and ECT measurements would constrain the range of EC loading and provide information on method performance. Further testing with standard reference materials of common environmental matrices supports the findings. Char and soot fractions of EC can be further separated using the IMPROVE protocol. The char/soot ratio was lower in street dusts (2.2 on average) than in soils (5.2 on average), most likely reflecting motor vehicle emissions. The soot concentrations agreed with EC from CTO-375, a pure thermal method. PMID:24358286
Van Ginderdeuren, Rita; Van Calster, Joachim; Stalmans, Peter; Van den Oord, Joost
2014-08-01
In this prospective study, a universal protocol for sampling and analysing vitreous material was investigated. Vitreous biopsies are difficult to handle because of the paucity of cells and the gelatinous structure of the vitreous. Histopathological analysis of the vitreous is useful in difficult uveitis cases to differentiate uveitis from lymphoma or infection and to define the type of cellular reaction. Hundred consecutive vitreous samples were analysed with the Cellient tissue processor (Hologic). This machine is a fully automated processor starting from a specified container with PreservCyt (fixative fluid) with cells to paraffin. Cytology was compared with fixatives Cytolyt (contains a mucolyticum) and PreservCyt. Routine histochemical and immunostainings were evaluated. In 92% of the cases, sufficient material was found for diagnosis. In 14%, a Cytolyt wash was necessary to prevent clotting of the tubes in the Cellient due to the viscosity of the sample. In 23%, the diagnosis was an acute inflammation (presence of granulocytes); in 33%, chronic active inflammation (presence of T lymphocytes); in 33%, low-grade inflammation (presence of CD68 cells, without T lymphocytes); and in 3%, a malignant process. A standardized protocol for sampling and handling vitreous biopsies, fixing in PreservCyt and processing by the Cellient gives a satisfactory result in morphology, number of cells and possibility of immuno-histochemical stainings. The diagnosis can be established or confirmed in more than 90% of cases. © 2014 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Tang, Xi-Jun; Yang, Ze; Chen, Xin-Bin; Tian, Wen-Fang; Tu, Cheng-Ning; Wang, Hai-Bo
2018-02-01
Salmonella spp./Shigella spp. are often associated with food poisoning and fecal-oral transmission of acute gastroenteritis that requires strict monitoring, especially among people who would handle food and water. In 2014, the National Health and Family Planning Commission of the P. R. China issued a national standard protocol (recommendatory) for the screening of Salmonella spp./Shigella spp.. However, its performance has not been fully studied. Whether it was suitable for use in our laboratory was still unknown. In the current study, the new protocol was first verified by various experiments and then its clinical performance was evaluated in about 20,000 stool samples over a three-year period. Verification results showed that the new protocol was highly specific and reproducible. Sensitivity (as defined as the lower limit of detection) of the new protocol at the PCR step was 10 3 CFU/mL and 10 1 CFU/mL for Salmonella spp. and Shigella spp., while that at the guided culture step was 10 4 CFU/mL and 10 3 CFU/mL, respectively. The large scale clinical evaluation indicated that the new protocol could increase the positivity rate by two fold and decrease the workload/median turnaround time significantly. In conclusion, the protocol was verified and evaluated and was proven to be a valuable platform for the rapid, specific, sensitive and high-throughput screening of Salmonella spp./Shigella spp. Copyright © 2017 Elsevier B.V. All rights reserved.
Faria-Ramos, I; Costa-de-Oliveira, S; Barbosa, J; Cardoso, A; Santos-Antunes, J; Rodrigues, A G; Pina-Vaz, C
2012-12-01
Culture in selective media represents the standard diagnostic method to confirm Legionella pneumophila infection, despite requiring a prolonged incubation period; antigen detection by immunofluorescence (IFS) and molecular techniques are also available, but they do not allow antimicrobial susceptibility evaluation. Our objective was to optimise flow cytometry (FC) protocols for the detection of L. pneumophila in respiratory samples and for susceptibility evaluation to first-line drugs. In order to optimise the FC protocol, a specific monoclonal antibody, conjugated with fluorescein isothiocyanate (FITC), was incubated with type strain L. pneumophila ATCC 33152. The limit of detection was established by analysing serial dilutions of bacterial suspension; specificity was assayed using mixtures of prokaryotic and eukaryotic microorganisms. The optimised FC protocol was used to assess 50 respiratory samples and compared with IFS evaluation. The susceptibility profile to erythromycin, ciprofloxacin and levofloxacin was evaluated by FC using propidium iodide and SYBR Green fluorescent dyes; the results were compared with the Etest afterwards. The optimal specific antibody concentration was 20 μg/ml; 10(2)/ml Legionella organisms were detected by this protocol and no cross-reactions with other microorganisms were detected. The five positive respiratory samples (10 %) determined by IFS were also detected by FC, showing 100 % correlation. After 1 h of incubation at 37 °C with different antimicrobials, SYBR Green staining could discriminate between treated and non-treated cells. A novel flow cytometric approach for the detection of L. pneumophila from clinical samples and susceptibility evaluation is now available, representing an important step forward for the diagnosis of this very relevant agent.
León, Ileana R.; Schwämmle, Veit; Jensen, Ole N.; Sprenger, Richard R.
2013-01-01
The majority of mass spectrometry-based protein quantification studies uses peptide-centric analytical methods and thus strongly relies on efficient and unbiased protein digestion protocols for sample preparation. We present a novel objective approach to assess protein digestion efficiency using a combination of qualitative and quantitative liquid chromatography-tandem MS methods and statistical data analysis. In contrast to previous studies we employed both standard qualitative as well as data-independent quantitative workflows to systematically assess trypsin digestion efficiency and bias using mitochondrial protein fractions. We evaluated nine trypsin-based digestion protocols, based on standard in-solution or on spin filter-aided digestion, including new optimized protocols. We investigated various reagents for protein solubilization and denaturation (dodecyl sulfate, deoxycholate, urea), several trypsin digestion conditions (buffer, RapiGest, deoxycholate, urea), and two methods for removal of detergents before analysis of peptides (acid precipitation or phase separation with ethyl acetate). Our data-independent quantitative liquid chromatography-tandem MS workflow quantified over 3700 distinct peptides with 96% completeness between all protocols and replicates, with an average 40% protein sequence coverage and an average of 11 peptides identified per protein. Systematic quantitative and statistical analysis of physicochemical parameters demonstrated that deoxycholate-assisted in-solution digestion combined with phase transfer allows for efficient, unbiased generation and recovery of peptides from all protein classes, including membrane proteins. This deoxycholate-assisted protocol was also optimal for spin filter-aided digestions as compared with existing methods. PMID:23792921
Landbird Monitoring Protocol for National Parks in the North Coast and Cascades Network
Siegel, Rodney B.; Wilkerson, Robert L.; Jenkins, Kurt J.; Kuntz, Robert C.; Boetsch, John R.; Schaberl, James P.; Happe, Patricia J.
2007-01-01
This protocol narrative outlines the rationale, sampling design and methods for monitoring landbirds in the North Coast and Cascades Network (NCCN) during the breeding season. The NCCN, one of 32 networks of parks in the National Park System, comprises seven national park units in the Pacific Northwest, including three large, mountainous, natural area parks (Mount Rainier [MORA] and Olympic [OLYM] National Parks, North Cascades National Park Service Complex [NOCA]), and four small historic cultural parks (Ebey's Landing National Historical Reserve [EBLA], Lewis and Clark National Historical Park [LEWI], Fort Vancouver National Historical Park [FOVA], and San Juan Island National Historical Park [SAJH]). The protocol reflects decisions made by the NCCN avian monitoring group, which includes NPS representatives from each of the large parks in the Network as well as personnel from the U.S. Geological Survey Forest and Rangeland Ecosystem Science Center (USGS-FRESC) Olympic Field Station, and The Institute for Bird Populations, at meetings held between 2000 (Siegel and Kuntz, 2000) and 2005. The protocol narrative describes the monitoring program in relatively broad terms, and its structure and content adhere to the outline and recommendations developed by Oakley and others (2003) and adopted by NPS. Finer details of the methodology are addressed in a set of standard operating procedures (SOPs) that accompany the protocol narrative. We also provide appendixes containing additional supporting materials that do not clearly belong in either the protocol narrative or the standard operating procedures.
Becheler, Ronan; Cassone, Anne-Laure; Noel, Philippe; Mouchel, Olivier; Morrison, Cheryl L.; Arnaud-Haond, Sophie
2017-01-01
Sampling in the deep sea is a technical challenge, which has hindered the acquisition of robust datasets that are necessary to determine the fine-grained biological patterns and processes that may shape genetic diversity. Estimates of the extent of clonality in deep-sea species, despite the importance of clonality in shaping the local dynamics and evolutionary trajectories, have been largely obscured by such limitations. Cold-water coral reefs along European margins are formed mainly by two reef-building species, Lophelia pertusa and Madrepora oculata. Here we present a fine-grained analysis of the genotypic and genetic composition of reefs occurring in the Bay of Biscay, based on an innovative deep-sea sampling protocol. This strategy was designed to be standardized, random, and allowed the georeferencing of all sampled colonies. Clonal lineages discriminated through their Multi-Locus Genotypes (MLG) at 6–7 microsatellite markers could thus be mapped to assess the level of clonality and the spatial spread of clonal lineages. High values of clonal richness were observed for both species across all sites suggesting a limited occurrence of clonality, which likely originated through fragmentation. Additionally, spatial autocorrelation analysis underlined the possible occurrence of fine-grained genetic structure in several populations of both L. pertusa and M. oculata. The two cold-water coral species examined had contrasting patterns of connectivity among canyons, with among-canyon genetic structuring detected in M. oculata, whereas L. pertusa was panmictic at the canyon scale. This study exemplifies that a standardized, random and georeferenced sampling strategy, while challenging, can be applied in the deep sea, and associated benefits outlined here include improved estimates of fine grained patterns of clonality and dispersal that are comparable across sites and among species.
NASA Astrophysics Data System (ADS)
Becheler, Ronan; Cassone, Anne-Laure; Noël, Philippe; Mouchel, Olivier; Morrison, Cheryl L.; Arnaud-Haond, Sophie
2017-11-01
Sampling in the deep sea is a technical challenge, which has hindered the acquisition of robust datasets that are necessary to determine the fine-grained biological patterns and processes that may shape genetic diversity. Estimates of the extent of clonality in deep-sea species, despite the importance of clonality in shaping the local dynamics and evolutionary trajectories, have been largely obscured by such limitations. Cold-water coral reefs along European margins are formed mainly by two reef-building species, Lophelia pertusa and Madrepora oculata. Here we present a fine-grained analysis of the genotypic and genetic composition of reefs occurring in the Bay of Biscay, based on an innovative deep-sea sampling protocol. This strategy was designed to be standardized, random, and allowed the georeferencing of all sampled colonies. Clonal lineages discriminated through their Multi-Locus Genotypes (MLG) at 6-7 microsatellite markers could thus be mapped to assess the level of clonality and the spatial spread of clonal lineages. High values of clonal richness were observed for both species across all sites suggesting a limited occurrence of clonality, which likely originated through fragmentation. Additionally, spatial autocorrelation analysis underlined the possible occurrence of fine-grained genetic structure in several populations of both L. pertusa and M. oculata. The two cold-water coral species examined had contrasting patterns of connectivity among canyons, with among-canyon genetic structuring detected in M. oculata, whereas L. pertusa was panmictic at the canyon scale. This study exemplifies that a standardized, random and georeferenced sampling strategy, while challenging, can be applied in the deep sea, and associated benefits outlined here include improved estimates of fine grained patterns of clonality and dispersal that are comparable across sites and among species.
Vignion-Dewalle, Anne-Sophie; Baert, Gregory; Devos, Laura; Thecua, Elise; Vicentini, Claire; Mortier, Laurent; Mordon, Serge
2017-09-01
Photodynamic therapy (PDT) is an emerging treatment modality for various diseases, especially for dermatological conditions. Although, the standard PDT protocol for the treatment of actinic keratoses in Europe has shown to be effective, treatment-associated pain is often observed in patients. Different modifications to this protocol attempted to decrease pain have been investigated. The decrease in fluence rate seems to be a promising solution. Moreover, it has been suggested that light fractionation significantly increases the efficacy of PDT. Based on a flexible light-emitting textile, the FLEXITHERALIGHT device specifically provides a fractionated illumination at a fluence rate more than six times lower than that of the standard protocol. In a recently completed clinical trial of PDT for the treatment of actinic keratosis, the non-inferiority of a protocol involving illumination with the FLEXITHERALIGHT device after a short incubation time and referred to as the FLEXITHERALIGHT protocol has been assessed compared to the standard protocol. In this paper, we propose a comparison of the two above mentioned 635 nm red light protocols with 37 J/cm 2 in the PDT treatment of actinic keratosis: the standard protocol and the FLEXITHERALIGHT one through a mathematical modeling. This mathematical modeling, which slightly differs from the one we have already published, enables the local damage induced by the therapy to be estimated. The comparison performed in terms of the local damage induced by the therapy demonstrates that the FLEXITHERALIGHT protocol with lower fluence rate, light fractionation and shorter incubation time is somewhat less efficient than the standard protocol. Nevertheless, from the clinical trial results, the FLEXITHERALIGHT protocol results in non-inferior response rates compared to the standard protocol. This finding raises the question of whether the PDT local damage achieved by the FLEXITHERALIGHT protocol (respectively, the standard protocol) is sufficient (respectively, excessive) to destroy actinic keratosis cells. Lasers Surg. Med. 49:686-697, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Phister, P. W., Jr.
1983-12-01
Development of the Air Force Institute of Technology's Digital Engineering Laboratory Network (DELNET) was continued with the development of an initial draft of a protocol standard for all seven layers as specified by the International Standards Organization's (ISO) Reference Model for Open Systems Interconnections. This effort centered on the restructuring of the Network Layer to perform Datagram routing and to conform to the developed protocol standards and actual software module development of the upper four protocol layers residing within the DELNET Monitor (Zilog MCZ 1/25 Computer System). Within the guidelines of the ISO Reference Model the Transport Layer was developed utilizing the Internet Header Format (IHF) combined with the Transport Control Protocol (TCP) to create a 128-byte Datagram. Also a limited Application Layer was created to pass the Gettysburg Address through the DELNET. This study formulated a first draft for the DELNET Protocol Standard and designed, implemented, and tested the Network, Transport, and Application Layers to conform to these protocol standards.
2012-01-01
Background Variability among stallions in terms of semen cryopreservation quality renders it difficult to arrive at a standardized cryopreservation method. Different extenders and processing techniques (such us colloidal centrifugation) are used in order to optimize post-thaw sperm quality. Sperm chromatin integrity analysis is an effective tool for assessing such quality. The aim of the present study was to compare the effect of two single layer colloidal centrifugation protocols (prior to cryopreservation) in combination with three commercial freezing extenders on the post-thaw chromatin integrity of equine sperm samples at different post-thaw incubation (37°C) times (i.e., their DNA fragmentation dynamics). Results Post-thaw DNA fragmentation levels in semen samples subjected to either of the colloidal centrifugation protocols were significantly lower (p<0.05) immediately after thawing and after 4 h of incubation at 37°C compared to samples that underwent standard (control) centrifugation. The use of InraFreeze® extender was associated with significantly less DNA fragmentation than the use of Botu-Crio® extender at 6 h of incubation, and than the use of either Botu-Crio® or Gent® extender at 24 h of incubation (p<0.05). Conclusions These results suggest that single layer colloidal centrifugation performed with extended or raw semen prior to cryopreservation reduces DNA fragmentation during the first four hours after thawing. Further studies are needed to determine the influence of freezing extenders on equine sperm DNA fragmentation dynamics. PMID:23217215
Documentation of operational protocol for the use of MAMA software
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schwartz, Daniel S.
2016-01-21
Image analysis of Scanning Electron Microscope (SEM) micrographs is a complex process that can vary significantly between analysts. The factors causing the variation are numerous, and the purpose of Task 2b is to develop and test a set of protocols designed to minimize variation in image analysis between different analysts and laboratories, specifically using the MAMA software package, Version 2.1. The protocols were designed to be “minimally invasive”, so that expert SEM operators will not be overly constrained in the way they analyze particle samples. The protocols will be tested using a round-robin approach where results from expert SEM usersmore » at Los Alamos National Laboratory, Lawrence Livermore National Laboratory, Pacific Northwest National Laboratory, Savannah River National Laboratory, and the National Institute of Standards and Testing will be compared. The variation of the results will be used to quantify uncertainty in the particle image analysis process. The round-robin exercise will proceed with 3 levels of rigor, each with their own set of protocols, as described below in Tasks 2b.1, 2b.2, and 2b.3. The uncertainty will be developed using NIST standard reference material SRM 1984 “Thermal Spray Powder – Particle Size Distribution, Tungsten Carbide/Cobalt (Acicular)” [Reference 1]. Full details are available in the Certificate of Analysis, posted on the NIST website (http://www.nist.gov/srm/).« less
Use of nested PCR to detect Ceratocystis fagacearum in sapwood of diseased northern oak species
USDA-ARS?s Scientific Manuscript database
Early and accurate diagnosis of oak wilt, caused by Ceratocystis fagacearum (Cf), is important when disease control action is planned. When laboratory diagnosis is needed, standard isolation protocols that are used rely on high quality samples and require > 14 days for incubation. Use of a nested P...
This technical report provides a description of the field project design, quality control, the sampling protocols and analysis methodology used, and standard operating procedures for the South Fork Broad River Watershed (SFBR) Total Maximum Daily Load (TMDL) project. This watersh...
Not Just a Prayer before a Test: Theodicy among Students
ERIC Educational Resources Information Center
Daugherty, Timothy K.; Han, Suejung
2016-01-01
The purpose of this study was to examine the potential social and academic impact of theodicy, perceived control of events by God. The sample included 428 college students from two public universities, consenting to complete internet-based protocols. Standardized measures included the Theodicy Scale (Daugherty et al., 2009), Work Related…
Richards-Kortum, Rebecca
2015-01-01
It was recently demonstrated that recombinase polymerase amplification (RPA), an isothermal amplification platform for pathogen detection, may be used to quantify DNA sample concentration using a standard curve. In this manuscript, a detailed protocol for developing and implementing a real-time quantitative recombinase polymerase amplification assay (qRPA assay) is provided. Using HIV-1 DNA quantification as an example, the assembly of real-time RPA reactions, the design of an internal positive control (IPC) sequence, and co-amplification of the IPC and target of interest are all described. Instructions and data processing scripts for the construction of a standard curve using data from multiple experiments are provided, which may be used to predict the concentration of unknown samples or assess the performance of the assay. Finally, an alternative method for collecting real-time fluorescence data with a microscope and a stage heater as a step towards developing a point-of-care qRPA assay is described. The protocol and scripts provided may be used for the development of a qRPA assay for any DNA target of interest. PMID:25867513
Crannell, Zachary A; Rohrman, Brittany; Richards-Kortum, Rebecca
2015-03-30
It was recently demonstrated that recombinase polymerase amplification (RPA), an isothermal amplification platform for pathogen detection, may be used to quantify DNA sample concentration using a standard curve. In this manuscript, a detailed protocol for developing and implementing a real-time quantitative recombinase polymerase amplification assay (qRPA assay) is provided. Using HIV-1 DNA quantification as an example, the assembly of real-time RPA reactions, the design of an internal positive control (IPC) sequence, and co-amplification of the IPC and target of interest are all described. Instructions and data processing scripts for the construction of a standard curve using data from multiple experiments are provided, which may be used to predict the concentration of unknown samples or assess the performance of the assay. Finally, an alternative method for collecting real-time fluorescence data with a microscope and a stage heater as a step towards developing a point-of-care qRPA assay is described. The protocol and scripts provided may be used for the development of a qRPA assay for any DNA target of interest.
Optimizing the MAC Protocol in Localization Systems Based on IEEE 802.15.4 Networks
Claver, Jose M.; Ezpeleta, Santiago
2017-01-01
Radio frequency signals are commonly used in the development of indoor localization systems. The infrastructure of these systems includes some beacons placed at known positions that exchange radio packets with users to be located. When the system is implemented using wireless sensor networks, the wireless transceivers integrated in the network motes are usually based on the IEEE 802.15.4 standard. But, the CSMA-CA, which is the basis for the medium access protocols in this category of communication systems, is not suitable when several users want to exchange bursts of radio packets with the same beacon to acquire the radio signal strength indicator (RSSI) values needed in the location process. Therefore, new protocols are necessary to avoid the packet collisions that appear when multiple users try to communicate with the same beacons. On the other hand, the RSSI sampling process should be carried out very quickly because some systems cannot tolerate a large delay in the location process. This is even more important when the RSSI sampling process includes measures with different signal power levels or frequency channels. The principal objective of this work is to speed up the RSSI sampling process in indoor localization systems. To achieve this objective, the main contribution is the proposal of a new MAC protocol that eliminates the medium access contention periods and decreases the number of packet collisions to accelerate the RSSI collection process. Moreover, the protocol increases the overall network throughput taking advantage of the frequency channel diversity. The presented results show the suitability of this protocol for reducing the RSSI gathering delay and increasing the network throughput in simulated and real environments. PMID:28684666
Optimizing the MAC Protocol in Localization Systems Based on IEEE 802.15.4 Networks.
Pérez-Solano, Juan J; Claver, Jose M; Ezpeleta, Santiago
2017-07-06
Radio frequency signals are commonly used in the development of indoor localization systems. The infrastructure of these systems includes some beacons placed at known positions that exchange radio packets with users to be located. When the system is implemented using wireless sensor networks, the wireless transceivers integrated in the network motes are usually based on the IEEE 802.15.4 standard. But, the CSMA-CA, which is the basis for the medium access protocols in this category of communication systems, is not suitable when several users want to exchange bursts of radio packets with the same beacon to acquire the radio signal strength indicator (RSSI) values needed in the location process. Therefore, new protocols are necessary to avoid the packet collisions that appear when multiple users try to communicate with the same beacons. On the other hand, the RSSI sampling process should be carried out very quickly because some systems cannot tolerate a large delay in the location process. This is even more important when the RSSI sampling process includes measures with different signal power levels or frequency channels. The principal objective of this work is to speed up the RSSI sampling process in indoor localization systems. To achieve this objective, the main contribution is the proposal of a new MAC protocol that eliminates the medium access contention periods and decreases the number of packet collisions to accelerate the RSSI collection process. Moreover, the protocol increases the overall network throughput taking advantage of the frequency channel diversity. The presented results show the suitability of this protocol for reducing the RSSI gathering delay and increasing the network throughput in simulated and real environments.
Benitex, Yulia; McNaney, Colleen A; Luchetti, David; Schaeffer, Eric; Olah, Timothy V; Morgan, Daniel G; Drexler, Dieter M
2013-08-30
Research on disorders of the central nervous system (CNS) has shown that an imbalance in the levels of specific endogenous neurotransmitters may underlie certain CNS diseases. These alterations in neurotransmitter levels may provide insight into pathophysiology, but can also serve as disease and pharmacodynamic biomarkers. To measure these potential biomarkers in vivo, the relevant sample matrix is cerebrospinal fluid (CSF), which is in equilibrium with the brain's interstitial fluid and circulates through the ventricular system of the brain and spinal cord. Accurate analysis of these potential biomarkers can be challenging due to low CSF sample volume, low analyte levels, and potential interferences from other endogenous compounds. A protocol has been established for effective method development of bioanalytical assays for endogenous compounds in CSF. Database searches and standard-addition experiments are employed to qualify sample preparation and specificity of the detection thus evaluating accuracy and precision. This protocol was applied to the study of the histaminergic neurotransmitter system and the analysis of histamine and its metabolite 1-methylhistamine in rat CSF. The protocol resulted in a specific and sensitive novel method utilizing pre-column derivatization ultra high performance liquid chromatography/tandem mass spectrometry (UHPLC/MS/MS), which is also capable of separating an endogenous interfering compound, identified as taurine, from the analytes of interest. Copyright © 2013 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Panteliadis, P.; Hafkenscheid, T.; Cary, B.; Diapouli, E.; Fischer, A.; Favez, O.; Quincey, P.; Viana, M.; Hitzenberger, R.; Vecchi, R.; Saraga, D.; Sciare, J.; Jaffrezo, J. L.; John, A.; Schwarz, J.; Giannoni, M.; Novak, J.; Karanasiou, A.; Fermo, P.; Maenhaut, W.
2015-02-01
A comparison exercise on thermal-optical elemental carbon/organic carbon (ECOC) analysers was carried out among 17 European laboratories. Contrary to previous comparison exercises, the 17 participants made use of an identical instrument set-up, after correcting for temperature offsets with the application of a recently developed temperature calibration kit (Sunset Laboratory Inc, OR, US). Temperature offsets reported by participants ranged from -93 to +100 °C per temperature step. Five filter samples and two sucrose solutions were analysed with both the EUSAAR2 and NIOSH870 thermal protocols. z scores were calculated for total carbon (TC); nine outliers and three stragglers were identified. Three outliers and eight stragglers were found for EC. Overall, the participants provided results between the warning levels with the exception of two laboratories that showed poor performance, the causes of which were identified and corrected through the course of the comparison exercise. The TC repeatability and reproducibility (expressed as relative standard deviations) were 11 and 15% for EUSAAR2 and 9.2 and 12% for NIOSH870; the standard deviations for EC were 15 and 20% for EUSAAR2 and 20 and 26% for NIOSH870. TC was in good agreement between the two protocols, TCNIOSH870 = 0.98 × TCEUSAAR2 (R2 = 1.00, robust means). Transmittance (TOT) calculated EC for NIOSH870 was found to be 20% lower than for EUSAAR2, ECNIOSH870 = 0.80 × ECEUSAAR2 (R2 = 0.96, robust means). The thermograms and laser signal values were compared and similar peak patterns were observed per sample and protocol for most participants. Notable deviations from the typical patterns indicated either the absence or inaccurate application of the temperature calibration procedure and/or pre-oxidation during the inert phase of the analysis. Low or zero pyrolytic organic carbon (POC), as reported by a few participants, is suggested as an indicator of an instrument-specific pre-oxidation. A sample-specific pre-oxidation effect was observed for filter G, for all participants and both thermal protocols, indicating the presence of oxygen donors on the suspended particulate matter. POC (TOT) levels were lower for NIOSH870 than for EUSAAR2, which is related to the heating profile differences of the two thermal protocols.
Hoople, Gordon D; Richards, Andrew; Wu, Yan; Pisano, Albert P; Zhang, Kun
2018-03-26
The ability to amplify and sequence either DNA or RNA from small starting samples has only been achieved in the last five years. Unfortunately, the standard protocols for generating genomic or transcriptomic libraries are incompatible and researchers must choose whether to sequence DNA or RNA for a particular sample. Gel-seq solves this problem by enabling researchers to simultaneously prepare libraries for both DNA and RNA starting with 100 - 1000 cells using a simple hydrogel device. This paper presents a detailed approach for the fabrication of the device as well as the biological protocol to generate paired libraries. We designed Gel-seq so that it could be easily implemented by other researchers; many genetics labs already have the necessary equipment to reproduce the Gel-seq device fabrication. Our protocol employs commonly-used kits for both whole-transcript amplification (WTA) and library preparation, which are also likely to be familiar to researchers already versed in generating genomic and transcriptomic libraries. Our approach allows researchers to bring to bear the power of both DNA and RNA sequencing on a single sample without splitting and with negligible added cost.
Young, William F; Stanson, Anthony W
2009-01-01
Adrenal venous sampling (AVS) is the criterion standard to distinguish between unilateral and bilateral adrenal disease in patients with primary aldosteronism. The keys to successful AVS include appropriate patient selection, careful patient preparation, focused technical expertise, defined protocol, and accurate data interpretation. The use of AVS should be based on patient preferences, patient age, clinical comorbidities, and the clinical probability of finding an aldosterone-producing adenoma. AVS is optimally performed in the fasting state in the morning. AVS is an intricate procedure because the right adrenal vein is small and may be difficult to locate - the success rate depends on the proficiency of the angiographer. The key factors that determine the successful catheterization of both adrenal veins are experience, dedication and repetition. With experience, and focusing the expertise to 1 or 2 radiologists at a referral centre, the AVS success rate can be as high as 96%. A centre-specific, written protocol is mandatory. The protocol should be developed by an interested group of endocrinologists, radiologists and laboratory personnel. Safeguards should be in place to prevent mislabelling of the blood tubes in the radiology suite and to prevent sample mix-up in the laboratory.
Sample of a client intake information protocol: a synopsis and rationale.
Green, Shari
2012-11-01
The utilization of standardized comprehensive forms in the field of orofacial myology is crucial as this profession continues to grow and establish assessment and treatment protocols. This article formally presents a comprehensive health history intake form currently in use, and highlights the rationale for each particular question within this form in an effort to explore the evidence-based theory behind each question utilized. Highlighting the importance of obtaining a thorough health history as it pertains to our profession, personally allows the clinician to ultimately best plan a therapeutic strategy and assess the individual criteria necessary for successful orofacial myofunctional habituation.
Essers, Geurt; Kramer, Anneke; Andriesse, Boukje; van Weel, Chris; van der Vleuten, Cees; van Dulmen, Sandra
2013-05-22
Assessment of medical communication performance usually focuses on rating generically applicable, well-defined communication skills. However, in daily practice, communication is determined by (specific) context factors, such as acquaintance with the patient, or the presented problem. Merely valuing the presence of generic skills may not do justice to the doctor's proficiency.Our aim was to perform an exploratory study on how assessment of general practitioner (GP) communication performance changes if context factors are explicitly taken into account. We used a mixed method design to explore how ratings would change. A random sample of 40 everyday GP consultations was used to see if previously identified context factors could be observed again. The sample was rated twice using a widely used assessment instrument (the MAAS-Global), first in the standard way and secondly after context factors were explicitly taken into account, by using a context-specific rating protocol to assess communication performance in the workplace. In between first and second rating, the presence of context factors was established. Item score differences were calculated using paired sample t-tests. In 38 out of 40 consultations, context factors prompted application of the context-specific rating protocol. Mean overall score on the 7-point MAAS-Global scale increased from 2.98 in standard to 3.66 in the context-specific rating (p<0.00); the effect size for the total mean score was 0.84. In earlier research the minimum standard score for adequate communication was set at 3.17. Applying the protocol, the mean overall score rose above the level set in an earlier study for the MAAS-Global scores to represent 'adequate GP communication behaviour'. Our findings indicate that incorporating context factors in communication assessment thus makes a meaningful difference and shows that context factors should be considered as 'signal' instead of 'noise' in GP communication assessment. Explicating context factors leads to a more deliberate and transparent rating of GP communication performance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1997-08-01
General Atomics (GA) leads a team of industrial, academic, and government organizations in the development of the Environmental Systems Management, Analysis and Reporting neTwork (E-SMART) for the Defense Advanced Research Project Agency (DARPA), by way of this Technology Reinvestment Project (TRP). E-SMART defines a standard by which networks of smart sensing, sampling, and control devices can interoperate. E-SMART is intended to be an open standard, available to any equipment manufacturer. The user will be provided a standard platform on which a site-specific monitoring plan can be implemented using sensors and actuators from various manufacturers and upgraded as new monitoring devicesmore » become commercially available. This project will further develop and advance the E-SMART standardized network protocol to include new sensors, sampling systems, and graphical user interfaces.« less
Fisher, Shawn C.; Reilly, Timothy J.; Jones, Daniel K.; Benzel, William M.; Griffin, Dale W.; Loftin, Keith A.; Iwanowicz, Luke R.; Cohl, Jonathan A.
2015-12-17
An understanding of the effects on human and ecological health brought by major coastal storms or flooding events is typically limited because of a lack of regionally consistent baseline and trends data in locations proximal to potential contaminant sources and mitigation activities, sensitive ecosystems, and recreational facilities where exposures are probable. In an attempt to close this gap, the U.S. Geological Survey (USGS) has implemented the Sediment-bound Contaminant Resiliency and Response (SCoRR) strategy pilot study to collect regional sediment-quality data prior to and in response to future coastal storms. The standard operating procedure (SOP) detailed in this document serves as the sample-collection protocol for the SCoRR strategy by providing step-by-step instructions for site preparation, sample collection and processing, and shipping of soil and surficial sediment (for example, bed sediment, marsh sediment, or beach material). The objectives of the SCoRR strategy pilot study are (1) to create a baseline of soil-, sand-, marsh sediment-, and bed-sediment-quality data from sites located in the coastal counties from Maine to Virginia based on their potential risk of being contaminated in the event of a major coastal storm or flooding (defined as Resiliency mode); and (2) respond to major coastal storms and flooding by reoccupying select baseline sites and sampling within days of the event (defined as Response mode). For both modes, samples are collected in a consistent manner to minimize bias and maximize quality control by ensuring that all sampling personnel across the region collect, document, and process soil and sediment samples following the procedures outlined in this SOP. Samples are analyzed using four USGS-developed screening methods—inorganic geochemistry, organic geochemistry, pathogens, and biological assays—which are also outlined in this SOP. Because the SCoRR strategy employs a multi-metric approach for sample analyses, this protocol expands upon and reconciles differences in the sample collection protocols outlined in the USGS “National Field Manual for the Collection of Water-Quality Data,” which should be used in conjunction with this SOP. A new data entry and sample tracking system also is presented to ensure all relevant data and metadata are gathered at the sample locations and in the laboratories.
Sampling methods for the study of pneumococcal carriage: a systematic review.
Gladstone, R A; Jefferies, J M; Faust, S N; Clarke, S C
2012-11-06
Streptococcus pneumoniae is an important pathogen worldwide. Accurate sampling of S. pneumoniae carriage is central to surveillance studies before and following conjugate vaccination programmes to combat pneumococcal disease. Any bias introduced during sampling will affect downstream recovery and typing. Many variables exist for the method of collection and initial processing, which can make inter-laboratory or international comparisons of data complex. In February 2003, a World Health Organisation working group published a standard method for the detection of pneumococcal carriage for vaccine trials to reduce or eliminate variability. We sought to describe the variables associated with the sampling of S. pneumoniae from collection to storage in the context of the methods recommended by the WHO and those used in pneumococcal carriage studies since its publication. A search of published literature in the online PubMed database was performed on the 1st June 2012, to identify published studies that collected pneumococcal carriage isolates, conducted after the publication of the WHO standard method. After undertaking a systematic analysis of the literature, we show that a number of differences in pneumococcal sampling protocol continue to exist between studies since the WHO publication. The majority of studies sample from the nasopharynx, but the choice of swab and swab transport media is more variable between studies. At present there is insufficient experimental data that supports the optimal sensitivity of any standard method. This may have contributed to incomplete adoption of the primary stages of the WHO detection protocol, alongside pragmatic or logistical issues associated with study design. Consequently studies may not provide a true estimate of pneumococcal carriage. Optimal sampling of carriage could lead to improvements in downstream analysis and the evaluation of pneumococcal vaccine impact and extrapolation to pneumococcal disease control therefore further in depth comparisons would be of value. Copyright © 2012 Elsevier Ltd. All rights reserved.
Evaluation of a Modified Pamidronate Protocol for the Treatment of Osteogenesis Imperfecta.
Palomo, Telma; Andrade, Maria C; Peters, Barbara S E; Reis, Fernanda A; Carvalhaes, João Tomás A; Glorieux, Francis H; Rauch, Frank; Lazaretti-Castro, Marise
2016-01-01
Intravenous pamidronate is widely used to treat children with osteogenesis imperfecta (OI). In a well-studied protocol ('standard protocol'), pamidronate is given at a daily dose of 1 mg per kg body weight over 4 h on 3 successive days; infusion cycles are repeated every 4 months. Here, we evaluated renal safety of a simpler protocol for intravenous pamidronate infusions (2 mg per kg body weight given in a single infusion over 2 h, repeated every 4 months; 'modified protocol'). Results of 18 patients with OI types I, III, or IV treated with the modified protocol for 12 months were compared to 18 historic controls, treated with standard protocol. In the modified protocol, mild transient post-infusion increases in serum creatinine were found during each infusion but after 12 months serum creatinine remained similar from baseline [0.40 mg/dl (SD: 0.13)] to the end of the study [0.41 mg/dl (SD: 0.11)] (P = 0.79). The two protocols led to similar changes in serum creatinine during the first pamidronate infusion [modified protocol: +2% (SD: 21%); standard protocol: -3% (SD: 8%); P = 0.32]. Areal lumbar spine bone mineral density Z-scores increased from -2.7 (SD: 1.5) to -1.8 (SD: 1.4) with the modified protocol, and from -4.1 (SD: 1.4) to -3.1 (SD: 1.1) with standard protocol (P = 0.68 for group differences in bone density Z-score changes). The modified pamidronate protocol is safe and may have similar effects on bone density as the standard pamidronate protocol. More studies are needed with longer follow-up to prove anti-fracture efficacy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reece, Charles E.; Ciancio, Elizabeth J.; Keyes, Katharine A.
2009-11-01
Particulate contamination on the surface of SRF cavities limits their performance via the enhanced generation of field-emitted electrons. Considerable efforts are expended to actively clean and avoid such contamination on niobium surfaces. The protocols in active use have been developed via feedback from cavity testing. This approach has the risk of over-conservatively ratcheting an ever increasing complexity of methods tied to particular circumstances. A complementary and perhaps helpful approach is to quantitatively assess the effectiveness of candidate methods at removing intentional representative particulate contamination. Toward this end, we developed a standardized contamination protocol using water suspensions of Nb{sub 2}O{sub 5}more » and SS 316 powders applied to BCP’d surfaces of standardized niobium samples yielding particle densities of order 200 particles/mm{sup 2}. From these starting conditions, controlled application of high pressure water rinse, ultrasonic cleaning, or CO{sub 2} snow jet cleaning was applied and the resulting surfaces examined via SEM/scanning EDS with particle recognition software. Results of initial parametric variations of each will be reported.« less
Shanks, O.C.; Sivaganesan, M.; Peed, L.; Kelty, C.A.; Blackwood, A.D.; Greene, M.R.; Noble, R.T.; Bushon, R.N.; Stelzer, E.A.; Kinzelman, J.; Anan'Eva, T.; Sinigalliano, C.; Wanless, D.; Griffith, J.; Cao, Y.; Weisberg, S.; Harwood, V.J.; Staley, C.; Oshima, K.H.; Varma, M.; Haugland, R.A.
2012-01-01
The application of quantitative real-time PCR (qPCR) technologies for the rapid identification of fecal bacteria in environmental waters is being considered for use as a national water quality metric in the United States. The transition from research tool to a standardized protocol requires information on the reproducibility and sources of variation associated with qPCR methodology across laboratories. This study examines interlaboratory variability in the measurement of enterococci and Bacteroidales concentrations from standardized, spiked, and environmental sources of DNA using the Entero1a and GenBac3 qPCR methods, respectively. Comparisons are based on data generated from eight different research facilities. Special attention was placed on the influence of the DNA isolation step and effect of simplex and multiplex amplification approaches on interlaboratory variability. Results suggest that a crude lysate is sufficient for DNA isolation unless environmental samples contain substances that can inhibit qPCR amplification. No appreciable difference was observed between simplex and multiplex amplification approaches. Overall, interlaboratory variability levels remained low (<10% coefficient of variation) regardless of qPCR protocol. ?? 2011 American Chemical Society.
Sud, Manish; Fahy, Eoin; Cotter, Dawn; Azam, Kenan; Vadivelu, Ilango; Burant, Charles; Edison, Arthur; Fiehn, Oliver; Higashi, Richard; Nair, K. Sreekumaran; Sumner, Susan; Subramaniam, Shankar
2016-01-01
The Metabolomics Workbench, available at www.metabolomicsworkbench.org, is a public repository for metabolomics metadata and experimental data spanning various species and experimental platforms, metabolite standards, metabolite structures, protocols, tutorials, and training material and other educational resources. It provides a computational platform to integrate, analyze, track, deposit and disseminate large volumes of heterogeneous data from a wide variety of metabolomics studies including mass spectrometry (MS) and nuclear magnetic resonance spectrometry (NMR) data spanning over 20 different species covering all the major taxonomic categories including humans and other mammals, plants, insects, invertebrates and microorganisms. Additionally, a number of protocols are provided for a range of metabolite classes, sample types, and both MS and NMR-based studies, along with a metabolite structure database. The metabolites characterized in the studies available on the Metabolomics Workbench are linked to chemical structures in the metabolite structure database to facilitate comparative analysis across studies. The Metabolomics Workbench, part of the data coordinating effort of the National Institute of Health (NIH) Common Fund's Metabolomics Program, provides data from the Common Fund's Metabolomics Resource Cores, metabolite standards, and analysis tools to the wider metabolomics community and seeks data depositions from metabolomics researchers across the world. PMID:26467476
Su, Yushan; Hung, Hayley; Stern, Gary; Sverko, Ed; Lao, Randy; Barresi, Enzo; Rosenberg, Bruno; Fellin, Phil; Li, Henrik; Xiao, Hang
2011-11-01
Initiated in 1992, air monitoring of organic pollutants in the Canadian Arctic provided spatial and temporal trends in support of Canada's participation in the Stockholm Convention of Persistent Organic Pollutants. The specific analytical laboratory charged with this task was changed in 2002 while field sampling protocols remained unchanged. Three rounds of intensive comparison studies were conducted in 2004, 2005, and 2008 to assess data comparability between the two laboratories. Analysis was compared for organochlorine pesticides (OCPs), polychlorinated biphenyls (PCBs) and polycyclic aromatic hydrocarbons (PAHs) in standards, blind samples of mixed standards and extracts of real air samples. Good measurement accuracy was achieved for both laboratories when standards were analyzed. Variation of measurement accuracy over time was found for some OCPs and PCBs in standards on a random and non-systematic manner. Relatively low accuracy in analyzing blind samples was likely related to the process of sample purification. Inter-laboratory measurement differences for standards (<30%) and samples (<70%) were generally less than or comparable to those reported in a previous inter-laboratory study with 21 participating laboratories. Regression analysis showed inconsistent data comparability between the two laboratories during the initial stages of the study. These inter-laboratory differences can complicate abilities to discern long-term trends of pollutants in a given sampling site. It is advisable to maintain long-term measurements with minimal changes in sample analysis.
Improved ASTM G72 Test Method for Ensuring Adequate Fuel-to-Oxidizer Ratios
NASA Technical Reports Server (NTRS)
Juarez, Alfredo; Harper, Susana A.
2016-01-01
The ASTM G72/G72M-15 Standard Test Method for Autogenous Ignition Temperature of Liquids and Solids in a High-Pressure Oxygen-Enriched Environment is currently used to evaluate materials for the ignition susceptibility driven by exposure to external heat in an enriched oxygen environment. Testing performed on highly volatile liquids such as cleaning solvents has proven problematic due to inconsistent test results (non-ignitions). Non-ignition results can be misinterpreted as favorable oxygen compatibility, although they are more likely associated with inadequate fuel-to-oxidizer ratios. Forced evaporation during purging and inadequate sample size were identified as two potential causes for inadequate available sample material during testing. In an effort to maintain adequate fuel-to-oxidizer ratios within the reaction vessel during test, several parameters were considered, including sample size, pretest sample chilling, pretest purging, and test pressure. Tests on a variety of solvents exhibiting a range of volatilities are presented in this paper. A proposed improvement to the standard test protocol as a result of this evaluation is also presented. Execution of the final proposed improved test protocol outlines an incremental step method of determining optimal conditions using increased sample sizes while considering test system safety limits. The proposed improved test method increases confidence in results obtained by utilizing the ASTM G72 autogenous ignition temperature test method and can aid in the oxygen compatibility assessment of highly volatile liquids and other conditions that may lead to false non-ignition results.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Suckling, Tara; Smith, Tony; Reed, Warren
2013-06-15
Optimal arterial opacification is crucial in imaging the pulmonary arteries using computed tomography (CT). This poses the challenge of precisely timing data acquisition to coincide with the transit of the contrast bolus through the pulmonary vasculature. The aim of this quality assurance exercise was to investigate if a change in CT pulmonary angiography (CTPA) scanning protocol resulted in improved opacification of the pulmonary arteries. Comparison was made between the smart prep protocol (SPP) and the test bolus protocol (TBP) for opacification in the pulmonary trunk. A total of 160 CTPA examinations (80 using each protocol) performed between January 2010 andmore » February 2011 were assessed retrospectively. CT attenuation coefficients were measured in Hounsfield Units (HU) using regions of interest at the level of the pulmonary trunk. The average pixel value, standard deviation (SD), maximum, and minimum were recorded. For each of these variables a mean value was then calculated and compared for these two CTPA protocols. Minimum opacification of 200 HU was achieved in 98% of the TBP sample but only 90% of the SPP sample. The average CT attenuation over the pulmonary trunk for the SPP was 329 (SD = ±21) HU, whereas for the TBP it was 396 (SD = ±22) HU (P = 0.0017). The TBP also recorded higher maximum (P = 0.0024) and minimum (P = 0.0039) levels of opacification. This study has found that a TBP resulted in significantly better opacification of the pulmonary trunk than the SPP.« less
DDN (Defense Data Network) Protocol Handbook. Volume 1. DoD Military Standard Protocols
1985-12-01
official Military Standard communication protocols in use on the DDN are included, as are several ARPANET (Advanced Research Projects Agency Network... research protocols which are currently in use, and some protocols currently undergoing review. Tutorial information and auxiliary documents are also...compatible with DoD needs, by researchers wishing to improve the protocols, and by impleroentors of local area networks (LANs) wishing their
RNA-seq mixology: designing realistic control experiments to compare protocols and analysis methods
Holik, Aliaksei Z.; Law, Charity W.; Liu, Ruijie; Wang, Zeya; Wang, Wenyi; Ahn, Jaeil; Asselin-Labat, Marie-Liesse; Smyth, Gordon K.
2017-01-01
Abstract Carefully designed control experiments provide a gold standard for benchmarking different genomics research tools. A shortcoming of many gene expression control studies is that replication involves profiling the same reference RNA sample multiple times. This leads to low, pure technical noise that is atypical of regular studies. To achieve a more realistic noise structure, we generated a RNA-sequencing mixture experiment using two cell lines of the same cancer type. Variability was added by extracting RNA from independent cell cultures and degrading particular samples. The systematic gene expression changes induced by this design allowed benchmarking of different library preparation kits (standard poly-A versus total RNA with Ribozero depletion) and analysis pipelines. Data generated using the total RNA kit had more signal for introns and various RNA classes (ncRNA, snRNA, snoRNA) and less variability after degradation. For differential expression analysis, voom with quality weights marginally outperformed other popular methods, while for differential splicing, DEXSeq was simultaneously the most sensitive and the most inconsistent method. For sample deconvolution analysis, DeMix outperformed IsoPure convincingly. Our RNA-sequencing data set provides a valuable resource for benchmarking different protocols and data pre-processing workflows. The extra noise mimics routine lab experiments more closely, ensuring any conclusions are widely applicable. PMID:27899618
Reviving common standards in point-count surveys for broad inference across studies
Matsuoka, Steven M.; Mahon, C. Lisa; Handel, Colleen M.; Solymos, Peter; Bayne, Erin M.; Fontaine, Patricia C.; Ralph, C.J.
2014-01-01
We revisit the common standards recommended by Ralph et al. (1993, 1995a) for conducting point-count surveys to assess the relative abundance of landbirds breeding in North America. The standards originated from discussions among ornithologists in 1991 and were developed so that point-count survey data could be broadly compared and jointly analyzed by national data centers with the goals of monitoring populations and managing habitat. Twenty years later, we revisit these standards because (1) they have not been universally followed and (2) new methods allow estimation of absolute abundance from point counts, but these methods generally require data beyond the original standards to account for imperfect detection. Lack of standardization and the complications it introduces for analysis become apparent from aggregated data. For example, only 3% of 196,000 point counts conducted during the period 1992-2011 across Alaska and Canada followed the standards recommended for the count period and count radius. Ten-minute, unlimited-count-radius surveys increased the number of birds detected by >300% over 3-minute, 50-m-radius surveys. This effect size, which could be eliminated by standardized sampling, was ≥10 times the published effect sizes of observers, time of day, and date of the surveys. We suggest that the recommendations by Ralph et al. (1995a) continue to form the common standards when conducting point counts. This protocol is inexpensive and easy to follow but still allows the surveys to be adjusted for detection probabilities. Investigators might optionally collect additional information so that they can analyze their data with more flexible forms of removal and time-of-detection models, distance sampling, multiple-observer methods, repeated counts, or combinations of these methods. Maintaining the common standards as a base protocol, even as these study-specific modifications are added, will maximize the value of point-count data, allowing compilation and analysis by regional and national data centers.
Evaluation of empirical treatment for blood culture-negative endocarditis.
Menu, Estelle; Gouriet, Frédérique; Casalta, Jean-Paul; Tissot-Dupont, Hervé; Vecten, Maude; Saby, Ludivine; Hubert, Sandrine; Salaun, Erwan; Theron, Alexis; Grisoli, Dominique; Lavoute, Cécile; Collart, Frédéric; Habib, Gilbert; Raoult, Didier
2017-01-01
Much progress has been made in understanding the main causes of blood culture-negative endocarditis (BCNE). Few studies concerning BCNE treatment (due to previous antibiotics used or fastidious pathogens) are available. We performed this study to evaluate the effectiveness of our therapeutic protocol in BCNE, based on compliance with the protocol, outcome and 1 year mortality. We collected prospectively and analysed retrospectively cases of BCNE between 2002 and 2014, using a simplified and standardized protocol developed by our multidisciplinary team. We apply two kinds of protocols to treat BCNE, which include only four intravenous antimicrobial agents: amoxicillin, vancomycin, gentamicin and amphotericin B. We had 177 patients with definite BCNE. There were 154 (87.0%) patients treated with both appropriate antimicrobial agents and appropriate duration of treatment. We analysed the causes of inappropriate treatment in 13 (7.3%) cases and inappropriate duration in 10 (5.6%) cases. The treatment changes were justified in all cases except one of discharge against medical advice. The fatality rate was 5.1% (nine cases) and all deaths occurred in the group of patients who were treated with appropriate treatment; however, four deaths were not attributable to empirical treatment failure. Concerning the other deaths, the lack of surgical management, in association with empirical treatment, could explain our protocol's failure, such as poorly tolerated surgery. Our protocol is efficient and our mortality rate was low, compared with the literature review. This may result from a strategy that uses a sampling procedure and a standardized protocol at the same time. © The Author 2016. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Arabi, Yaseen M; Alothman, Adel; Balkhy, Hanan H; Al-Dawood, Abdulaziz; AlJohani, Sameera; Al Harbi, Shmeylan; Kojan, Suleiman; Al Jeraisy, Majed; Deeb, Ahmad M; Assiri, Abdullah M; Al-Hameed, Fahad; AlSaedi, Asim; Mandourah, Yasser; Almekhlafi, Ghaleb A; Sherbeeni, Nisreen Murad; Elzein, Fatehi Elnour; Memon, Javed; Taha, Yusri; Almotairi, Abdullah; Maghrabi, Khalid A; Qushmaq, Ismael; Al Bshabshe, Ali; Kharaba, Ayman; Shalhoub, Sarah; Jose, Jesna; Fowler, Robert A; Hayden, Frederick G; Hussein, Mohamed A
2018-01-30
It had been more than 5 years since the first case of Middle East Respiratory Syndrome coronavirus infection (MERS-CoV) was recorded, but no specific treatment has been investigated in randomized clinical trials. Results from in vitro and animal studies suggest that a combination of lopinavir/ritonavir and interferon-β1b (IFN-β1b) may be effective against MERS-CoV. The aim of this study is to investigate the efficacy of treatment with a combination of lopinavir/ritonavir and recombinant IFN-β1b provided with standard supportive care, compared to treatment with placebo provided with standard supportive care in patients with laboratory-confirmed MERS requiring hospital admission. The protocol is prepared in accordance with the SPIRIT (Standard Protocol Items: Recommendations for Interventional Trials) guidelines. Hospitalized adult patients with laboratory-confirmed MERS will be enrolled in this recursive, two-stage, group sequential, multicenter, placebo-controlled, double-blind randomized controlled trial. The trial is initially designed to include 2 two-stage components. The first two-stage component is designed to adjust sample size and determine futility stopping, but not efficacy stopping. The second two-stage component is designed to determine efficacy stopping and possibly readjustment of sample size. The primary outcome is 90-day mortality. This will be the first randomized controlled trial of a potential treatment for MERS. The study is sponsored by King Abdullah International Medical Research Center, Riyadh, Saudi Arabia. Enrollment for this study began in November 2016, and has enrolled thirteen patients as of Jan 24-2018. ClinicalTrials.gov, ID: NCT02845843 . Registered on 27 July 2016.
Bloemen, Elizabeth M.; Rosen, Tony; Schiroo, Justina A. Cline; Clark, Sunday; Mulcare, Mary R.; Stern, Michael E.; Mysliwiec, Regina; Flomenbaum, Neal E.; Lachs, Mark S.; Hargarten, Stephen
2016-01-01
Background Photographing injuries in the acute setting allows for improved documentation as well as assessment by clinicians and others who have not personally examined a patient. This tool is important, particularly for telemedicine, tracking of wound healing, the evaluation of potential abuse, and injury research. Despite this, protocols to ensure standardization of photography in clinical practice, forensics, or research have not been published. In preparation for a study of injury patterns in elder abuse and geriatric falls, our goal was to develop and evaluate a protocol for standardized photography of injuries that may be broadly applied. Methods We conducted a literature review for techniques and standards in medical, forensic, and legal photography. We developed a novel protocol describing types of photographs and body positioning for eight body regions, including instructional diagrams. We revised it iteratively in consultation with experts in medical photography; forensics; and elder, child, and domestic abuse. The resulting protocol requires a minimum of four photos of each injury at multiple distances with and without a ruler/color guide. To evaluate the protocol’s efficacy, multiple research assistants without previous photography experience photographed injuries from a convenience sample of elderly patients presenting to a single large, urban, academic emergency department. A selection of these patients’ images were then evaluated in a blinded fashion by four nontreating emergency medicine physicians and the inter-rater reliability between these physicians was calculated. Results Among the 131 injuries, from 53 patients, photographed by 18 photographers using this protocol, photographs of 25 injuries (10 bruises, seven lacerations, and eight abrasions) were used to assess characterization of the injury. Physicians’ characterizations of the injuries were reliable for the size of the injury (κ = 0.91, 95% confidence interval [CI] = 0.77 to 1.00), side of the body (κ = 0.97, 95% CI = 0.88 to 1.00), precise location of the injury (κ = 0.74, 95% CI = 0.63 = 0.81), and type of abrasion (κ = 0.76, 95% CI = 0.45 to 1.00). The exact shape of the injury (κ = 0.44, 95% CI = 0.17 to 0.51), and the primary color of bruises (κ = 0.37, 95% CI = 0.25 to 0.48) were not as reliably characterized. Conclusions Standardizing the documentation of injuries with photographs for clinical and research assessment can be conducted by nonprofessional photographers. A photography protocol will ensure that this important mechanism for documentation is optimized. PMID:26932497
Development of Gold Standard Ion-Selective Electrode-Based Methods for Fluoride Analysis
Martínez-Mier, E.A.; Cury, J.A.; Heilman, J.R.; Katz, B.P.; Levy, S.M.; Li, Y.; Maguire, A.; Margineda, J.; O’Mullane, D.; Phantumvanit, P.; Soto-Rojas, A.E.; Stookey, G.K.; Villa, A.; Wefel, J.S.; Whelton, H.; Whitford, G.M.; Zero, D.T.; Zhang, W.; Zohouri, V.
2011-01-01
Background/Aims: Currently available techniques for fluoride analysis are not standardized. Therefore, this study was designed to develop standardized methods for analyzing fluoride in biological and nonbiological samples used for dental research. Methods A group of nine laboratories analyzed a set of standardized samples for fluoride concentration using their own methods. The group then reviewed existing analytical techniques for fluoride analysis, identified inconsistencies in the use of these techniques and conducted testing to resolve differences. Based on the results of the testing undertaken to define the best approaches for the analysis, the group developed recommendations for direct and microdiffusion methods using the fluoride ion-selective electrode. Results Initial results demonstrated that there was no consensus regarding the choice of analytical techniques for different types of samples. Although for several types of samples, the results of the fluoride analyses were similar among some laboratories, greater differences were observed for saliva, food and beverage samples. In spite of these initial differences, precise and true values of fluoride concentration, as well as smaller differences between laboratories, were obtained once the standardized methodologies were used. Intraclass correlation coefficients ranged from 0.90 to 0.93, for the analysis of a certified reference material, using the standardized methodologies. Conclusion The results of this study demonstrate that the development and use of standardized protocols for F analysis significantly decreased differences among laboratories and resulted in more precise and true values. PMID:21160184
Park, Hyoung-Chul; Kim, Min Jeong; Lee, Bong Hwa
Although it is accepted that complicated appendicitis requires antibiotic therapy to prevent post-operative surgical infections, consensus protocols on the duration and regimens of treatment are not well established. This study aimed to compare the outcome of post-operative infectious complications in patients receiving old non-standardized and new standard antibiotic protocols, involving either 5 or 10 days of treatment, respectively. We enrolled 1,343 patients who underwent laparoscopic surgery for complicated appendicitis between January 2009 and December 2014. At the beginning of the new protocol, the patients were divided into two groups; 10 days of various antibiotic regimens (between January 2009 and June 2012, called the non-standardized protocol; n = 730) and five days of cefuroxime and metronidazole regimen (between July 2012 and December 2014; standardized protocol; n = 613). We compared the clinical outcomes, including surgical site infection (SSI) (superficial and deep organ/space infections) in the two groups. The standardized protocol group had a slightly shorter operative time (67 vs. 69 min), a shorter hospital stay (5 vs. 5.4 d), and lower medical cost (US$1,564 vs. US$1,654). Otherwise, there was no difference between the groups. No differences were found in the non-standardized and standard protocol groups with regard to the rate of superficial infection (10.3% vs. 12.7%; p = 0.488) or deep organ/space infection (2.3% vs. 2.1%; p = 0.797). In patients undergoing laparoscopic surgery for complicated appendicitis, five days of cefuroxime and metronidazole did not lead to more SSIs, and it decreased the medical costs compared with non-standardized antibiotic regimens.
Zboromyrska, Y; Rubio, E; Alejo, I; Vergara, A; Mons, A; Campo, I; Bosch, J; Marco, F; Vila, J
2016-06-01
The current gold standard method for the diagnosis of urinary tract infections (UTI) is urine culture that requires 18-48 h for the identification of the causative microorganisms and an additional 24 h until the results of antimicrobial susceptibility testing (AST) are available. The aim of this study was to shorten the time of urine sample processing by a combination of flow cytometry for screening and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) for bacterial identification followed by AST directly from urine. The study was divided into two parts. During the first part, 675 urine samples were processed by a flow cytometry device and a cut-off value of bacterial count was determined to select samples for direct identification by MALDI-TOF-MS at ≥5 × 10(6) bacteria/mL. During the second part, 163 of 1029 processed samples reached the cut-off value. The sample preparation protocol for direct identification included two centrifugation and two washing steps. Direct AST was performed by the disc diffusion method if a reliable direct identification was obtained. Direct MALDI-TOF-MS identification was performed in 140 urine samples; 125 of the samples were positive by urine culture, 12 were contaminated and 3 were negative. Reliable direct identification was obtained in 108 (86.4%) of the 125 positive samples. AST was performed in 102 identified samples, and the results were fully concordant with the routine method among 83 monomicrobial infections. In conclusion, the turnaround time of the protocol described to diagnose UTI was about 1 h for microbial identification and 18-24 h for AST. Copyright © 2016 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Stockton, Amanda M.; Chiesl, Thomas N.; Lowenstein, Tim K.; Amashukeli, Xenia; Grunthaner, Frank; Mathies, Richard A.
2009-11-01
The Mars Organic Analyzer (MOA) has enabled the sensitive detection of amino acid and amine biomarkers in laboratory standards and in a variety of field sample tests. However, the MOA is challenged when samples are extremely acidic and saline or contain polyvalent cations. Here, we have optimized the MOA analysis, sample labeling, and sample dilution buffers to handle such challenging samples more robustly. Higher ionic strength buffer systems with pKa values near pH 9 were developed to provide better buffering capacity and salt tolerance. The addition of ethylaminediaminetetraacetic acid (EDTA) ameliorates the negative effects of multivalent cations. The optimized protocol utilizes a 75 mM borate buffer (pH 9.5) for Pacific Blue labeling of amines and amino acids. After labeling, 50 mM (final concentration) EDTA is added to samples containing divalent cations to ameliorate their effects. This optimized protocol was used to successfully analyze amino acids in a saturated brine sample from Saline Valley, California, and a subcritical water extract of a highly acidic sample from the RÃo Tinto, Spain. This work expands the analytical capabilities of the MOA and increases its sensitivity and robustness for samples from extraterrestrial environments that may exhibit pH and salt extremes as well as metal ions.
Stockton, Amanda M; Chiesl, Thomas N; Lowenstein, Tim K; Amashukeli, Xenia; Grunthaner, Frank; Mathies, Richard A
2009-11-01
The Mars Organic Analyzer (MOA) has enabled the sensitive detection of amino acid and amine biomarkers in laboratory standards and in a variety of field sample tests. However, the MOA is challenged when samples are extremely acidic and saline or contain polyvalent cations. Here, we have optimized the MOA analysis, sample labeling, and sample dilution buffers to handle such challenging samples more robustly. Higher ionic strength buffer systems with pK(a) values near pH 9 were developed to provide better buffering capacity and salt tolerance. The addition of ethylaminediaminetetraacetic acid (EDTA) ameliorates the negative effects of multivalent cations. The optimized protocol utilizes a 75 mM borate buffer (pH 9.5) for Pacific Blue labeling of amines and amino acids. After labeling, 50 mM (final concentration) EDTA is added to samples containing divalent cations to ameliorate their effects. This optimized protocol was used to successfully analyze amino acids in a saturated brine sample from Saline Valley, California, and a subcritical water extract of a highly acidic sample from the Río Tinto, Spain. This work expands the analytical capabilities of the MOA and increases its sensitivity and robustness for samples from extraterrestrial environments that may exhibit pH and salt extremes as well as metal ions.
Towards a unified sampling terminology: clarifying misperceptions.
Thiex, Nancy; Paoletii, Claudia; Esbensen, Kim H
2015-01-01
International acceptance of data is a much-desired wish in many sectors to ensure equal standards for valid information and data exchange, facilitate trade, support food safety regulation, and promote reliable communication among all parties involved. However, this cannot be accomplished without a harmonized approach to sampling and a joint approach to assess the practical sampling protocols used. Harmonization based on a nonrepresentative protocol, or on a restricted terminology tradition forced upon other sectors would negate any constructive outcome. An international discussion on a harmonized approach to sampling is severely hampered by a plethora of divergent sampling definitions and terms. Different meanings for the same term are frequently used by the different sectors, and even within one specific sector. In other cases, different terms are used for the same concept. Before efforts to harmonize can be attempted, it is essential that all stakeholders can at least communicate effectively in this context. Therefore, a clear understanding of the main vocabularies becomes an essential prerequisite. As a first step, commonalities and dichotomies in terminology are here brought to attention by providing a comparative summary of the. terminology as defined by the Theory of Sampling {TOS) and those in current use by the International Organization for Standardization, the World Health Organization, the Food and Agriculture Organization Codex Alimentarius, and the U.S. Food and Drug Administration. Terms having contradictory meaning to the TOS are emphasized. To the degree possible, we present a successful resolution of some of the most important issues outlined, sufficient to support the objectives of the present Special Section.
Kaufman, David R; Sheehan, Barbara; Stetson, Peter; Bhatt, Ashish R; Field, Adele I; Patel, Chirag; Maisel, James Mark
2016-10-28
The process of documentation in electronic health records (EHRs) is known to be time consuming, inefficient, and cumbersome. The use of dictation coupled with manual transcription has become an increasingly common practice. In recent years, natural language processing (NLP)-enabled data capture has become a viable alternative for data entry. It enables the clinician to maintain control of the process and potentially reduce the documentation burden. The question remains how this NLP-enabled workflow will impact EHR usability and whether it can meet the structured data and other EHR requirements while enhancing the user's experience. The objective of this study is evaluate the comparative effectiveness of an NLP-enabled data capture method using dictation and data extraction from transcribed documents (NLP Entry) in terms of documentation time, documentation quality, and usability versus standard EHR keyboard-and-mouse data entry. This formative study investigated the results of using 4 combinations of NLP Entry and Standard Entry methods ("protocols") of EHR data capture. We compared a novel dictation-based protocol using MediSapien NLP (NLP-NLP) for structured data capture against a standard structured data capture protocol (Standard-Standard) as well as 2 novel hybrid protocols (NLP-Standard and Standard-NLP). The 31 participants included neurologists, cardiologists, and nephrologists. Participants generated 4 consultation or admission notes using 4 documentation protocols. We recorded the time on task, documentation quality (using the Physician Documentation Quality Instrument, PDQI-9), and usability of the documentation processes. A total of 118 notes were documented across the 3 subject areas. The NLP-NLP protocol required a median of 5.2 minutes per cardiology note, 7.3 minutes per nephrology note, and 8.5 minutes per neurology note compared with 16.9, 20.7, and 21.2 minutes, respectively, using the Standard-Standard protocol and 13.8, 21.3, and 18.7 minutes using the Standard-NLP protocol (1 of 2 hybrid methods). Using 8 out of 9 characteristics measured by the PDQI-9 instrument, the NLP-NLP protocol received a median quality score sum of 24.5; the Standard-Standard protocol received a median sum of 29; and the Standard-NLP protocol received a median sum of 29.5. The mean total score of the usability measure was 36.7 when the participants used the NLP-NLP protocol compared with 30.3 when they used the Standard-Standard protocol. In this study, the feasibility of an approach to EHR data capture involving the application of NLP to transcribed dictation was demonstrated. This novel dictation-based approach has the potential to reduce the time required for documentation and improve usability while maintaining documentation quality. Future research will evaluate the NLP-based EHR data capture approach in a clinical setting. It is reasonable to assert that EHRs will increasingly use NLP-enabled data entry tools such as MediSapien NLP because they hold promise for enhancing the documentation process and end-user experience. ©David R. Kaufman, Barbara Sheehan, Peter Stetson, Ashish R. Bhatt, Adele I. Field, Chirag Patel, James Mark Maisel. Originally published in JMIR Medical Informatics (http://medinform.jmir.org), 28.10.2016.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nielsen, Yousef W., E-mail: yujwni01@heh.regionh.d; Eiberg, Jonas P., E-mail: Eiberg@dadlnet.d; Logager, Vibeke B., E-mail: viloe@heh.regionh.d
The purpose of this study was to determine the diagnostic performance of 3T whole-body magnetic resonance angiography (WB-MRA) using a hybrid protocol in comparison with a standard protocol in patients with peripheral arterial disease (PAD). In 26 consecutive patients with PAD two different protocols were used for WB-MRA: a standard sequential protocol (n = 13) and a hybrid protocol (n = 13). WB-MRA was performed using a gradient echo sequence, body coil for signal reception, and gadoterate meglumine as contrast agent (0.3 mmol/kg body weight). Two blinded observers evaluated all WB-MRA examinations with regard to presence of stenoses, as wellmore » as diagnostic quality and degree of venous contamination in each of the four stations used in WB-MRA. Digital subtraction angiography served as the method of reference. Sensitivity for detecting significant arterial disease (luminal narrowing {>=} 50%) using standard-protocol WB-MRA for the two observers was 0.63 (95%CI: 0.51-0.73) and 0.66 (0.58-0.78). Specificities were 0.94 (0.91-0.97) and 0.96 (0.92-0.98), respectively. In the hybrid protocol WB-MRA sensitivities were 0.75 (0.64-0.84) and 0.70 (0.58-0.8), respectively. Specificities were 0.93 (0.88-0.96) and 0.95 (0.91-0.97). Interobserver agreement was good using both the standard and the hybrid protocol, with {kappa} = 0.62 (0.44-0.67) and {kappa} = 0.70 (0.59-0.79), respectively. WB-MRA quality scores were significantly higher in the lower leg using the hybrid protocol compared to standard protocol (p = 0.003 and p = 0.03, observers 1 and 2). Distal venous contamination scores were significantly lower with the hybrid protocol (p = 0.02 and p = 0.01, observers 1 and 2). In conclusion, hybrid-protocol WB-MRA shows a better diagnostic performance than standard protocol WB-MRA at 3 T in patients with PAD.« less
Bogdanovska-Todorovska, Magdalena; Petrushevska, Gordana; Janevska, Vesna; Spasevska, Liljana; Kostadinova-Kunovska, Slavica
2018-05-20
Accurate assessment of human epidermal growth factor receptor 2 (HER-2) is crucial in selecting patients for targeted therapy. Commonly used methods for HER-2 testing are immunohistochemistry (IHC) and fluorescence in situ hybridization (FISH). Here we presented the implementation, optimization and standardization of two FISH protocols using breast cancer samples and assessed the impact of pre-analytical and analytical factors on HER-2 testing. Formalin fixed paraffin embedded (FFPE) tissue samples from 70 breast cancer patients were tested for HER-2 using PathVysion™ HER-2 DNA Probe Kit and two different paraffin pretreatment kits, Vysis/Abbott Paraffin Pretreatment Reagent Kit (40 samples) and DAKO Histology FISH Accessory Kit (30 samples). The concordance between FISH and IHC results was determined. Pre-analytical and analytical factors (i.e., fixation, baking, digestion, and post-hybridization washing) affected the efficiency and quality of hybridization. The overall hybridization success in our study was 98.6% (69/70); the failure rate was 1.4%. The DAKO pretreatment kit was more time-efficient and resulted in more uniform signals that were easier to interpret, compared to the Vysis/Abbott kit. The overall concordance between IHC and FISH was 84.06%, kappa coefficient 0.5976 (p < 0.0001). The greatest discordance (82%) between IHC and FISH was observed in IHC 2+ group. A standardized FISH protocol for HER-2 assessment, with high hybridization efficiency, is necessary due to variability in tissue processing and individual tissue characteristics. Differences in the pre-analytical and analytical steps can affect the hybridization quality and efficiency. The use of DAKO pretreatment kit is time-saving and cost-effective.
Identification of phlebotomine sand fly blood meals by real-time PCR.
Sales, Kamila Gaudêncio da Silva; Costa, Pietra Lemos; de Morais, Rayana Carla Silva; Otranto, Domenico; Brandão-Filho, Sinval Pinto; Cavalcanti, Milena de Paiva; Dantas-Torres, Filipe
2015-04-16
Phlebotomine sand flies are blood-feeding insects of great medical and veterinary significance acting as vectors of Leishmania parasites. Studying the blood-feeding pattern of these insects may help in the understanding of their interactions with potential reservoir hosts of Leishmania parasites. In this study, we developed real time PCR assays for the identification of sand fly blood meal. Six pairs of primers were designed based on cytochrome b gene sequences available in GenBank of the following potential hosts: dog, cat, horse, chicken, black rat, and human. Firstly, SYBR Green-based real time PCR assays were conducted using a standard curve with eight different concentrations (i.e., 10 ng, 1 ng, 100 pg, 10 pg, 1 pg, 100 fg, 10 fg and 1 fg per 2 μl) of DNA samples extracted from EDTA blood samples from each target animal. Then, DNA samples extracted from field-collected engorged female sand flies belonging to three species (i.e., Lutzomyia longipalpis, L. migonei and L. lenti) were tested by the protocols standardized herein. Additionally, female sand flies were experimentally fed on a black rat (Rattus rattus) and used for evaluating the time course of the detection of the protocol targeting this species. The protocols performed well with detection limits of 10 pg to 100 fg. Field-collected female sand flies were fed on blood from humans (73%), chickens (23%), dogs (22%), horses (15%), black rats (11%) and cats (2%). Interestingly, 76.1% of the L. longipalpis females were positive for human blood. In total, 48% of the tested females were fed on single sources, 31% on two and 12% on three. The analysis of the time course showed that the real time PCR protocol targeting the black rat DNA was able to detect small amounts of the host DNA up to 5 days after the blood meal. The real time PCR assays standardized herein successfully detected small amounts of host DNA in female sand flies fed on different vertebrate species and, specifically for the black rats, up to 5 days after the blood meal. These assays represent promising tools for the identification of blood meal in field-collected female sand flies.
Gámez-Cenzano, Cristina; Pino-Sorroche, Francisco
2014-04-01
There is a growing interest in using quantification in FDG-PET/CT in oncology, especially for evaluating response to therapy. Complex full quantitative procedures with blood sampling and dynamic scanning have been clinically replaced by the use of standardized uptake value measurements that provide an index of regional tracer uptake normalized to the administered dose of FDG. Some approaches have been proposed for assessing quantitative metabolic response, such as EORTC and PERCIST criteria in solid tumors. When using standardized uptake value in clinical routine and multicenter trials, standardization of protocols and quality control procedures of instrumentation is required. Copyright © 2014 Elsevier Inc. All rights reserved.
López, Luisa F.; Muñoz, César O.; Cáceres, Diego H.; Tobón, Ángela M.; Loparev, Vladimir; Clay, Oliver; Chiller, Tom; Litvintseva, Anastasia; Gade, Lalitha; González, Ángel
2017-01-01
Histoplasmosis is considered one of the most important endemic and systemic mycoses worldwide. Until now few molecular techniques have been developed for its diagnosis. The aim of this study was to develop and evaluate three real time PCR (qPCR) protocols for different protein-coding genes (100-kDa, H and M antigens) using an animal model. Fresh and formalin-fixed and paraffin-embedded (FFPE) lung tissues from BALB/c mice inoculated i.n. with 2.5x106 Histoplasma capsulatum yeast or PBS were obtained at 1, 2, 3, 4, 8, 12 and 16 weeks post-infection. A collection of DNA from cultures representing different clades of H. capsulatum (30 strains) and other medically relevant pathogens (36 strains of related fungi and Mycobacterium tuberculosis) were used to analyze sensitivity and specificity. Analytical sensitivity and specificity were 100% when DNAs from the different strains were tested. The highest fungal burden occurred at first week post-infection and complete fungal clearance was observed after the third week; similar results were obtained when the presence of H. capsulatum yeast cells was demonstrated in histopathological analysis. In the first week post-infection, all fresh and FFPE lung tissues from H. capsulatum-infected animals were positive for the qPCR protocols tested except for the M antigen protocol, which gave variable results when fresh lung tissue samples were analyzed. In the second week, all qPCR protocols showed variable results for both fresh and FFPE tissues. Samples from the infected mice at the remaining times post-infection and uninfected mice (controls) were negative for all protocols. Good agreement was observed between CFUs, histopathological analysis and qPCR results for the 100-kDa and H antigen protocols. We successfully standardized and validated three qPCR assays for detecting H. capsulatum DNA in fresh and FFPE tissues, and conclude that the 100-kDa and H antigen molecular assays are promising tests for diagnosing this mycosis. PMID:29287097
Gross Motor Development in Children Aged 3-5 Years, United States 2012.
Kit, Brian K; Akinbami, Lara J; Isfahani, Neda Sarafrazi; Ulrich, Dale A
2017-07-01
Objective Gross motor development in early childhood is important in fostering greater interaction with the environment. The purpose of this study is to describe gross motor skills among US children aged 3-5 years using the Test of Gross Motor Development (TGMD-2). Methods We used 2012 NHANES National Youth Fitness Survey (NNYFS) data, which included TGMD-2 scores obtained according to an established protocol. Outcome measures included locomotor and object control raw and age-standardized scores. Means and standard errors were calculated for demographic and weight status with SUDAAN using sample weights to calculate nationally representative estimates, and survey design variables to account for the complex sampling methods. Results The sample included 339 children aged 3-5 years. As expected, locomotor and object control raw scores increased with age. Overall mean standardized scores for locomotor and object control were similar to the mean value previously determined using a normative sample. Girls had a higher mean locomotor, but not mean object control, standardized score than boys (p < 0.05). However, the mean locomotor standardized scores for both boys and girls fell into the range categorized as "average." There were no other differences by age, race/Hispanic origin, weight status, or income in either of the subtest standardized scores (p > 0.05). Conclusions In a nationally representative sample of US children aged 3-5 years, TGMD-2 mean locomotor and object control standardized scores were similar to the established mean. These results suggest that standardized gross motor development among young children generally did not differ by demographic or weight status.
Taliaferro, Lindsay A; Hetler, Joel; Edwall, Glenace; Wright, Catherine; Edwards, Anne R; Borowsky, Iris W
2013-06-01
To compare depression identification and management perceptions and practices between professions and disciplines in primary care and examine factors that increase the likelihood of administering a standardized depression screening instrument, asking about patients' depressive symptoms, and using best practice when managing depressed adolescents. Data came from an online survey of clinicians in Minnesota (20% response rate). Analyses involved bivariate tests and linear regressions. The analytic sample comprised 260 family medicine physicians, 127 pediatricians, 96 family nurse practitioners, and 54 pediatric nurse practitioners. Overall, few differences emerged between physicians and nurse practitioners or family and pediatric clinicians regarding addressing depression among adolescents. Two factors associated with administering a standardized instrument included having clear protocols for follow-up after depression screening and feeling better prepared to address depression among adolescents. Enhancing clinicians' competence to address depression and developing postscreening protocols could help providers implement universal screening in primary care.
The Interlibrary Loan Protocol: An OSI Solution to ILL Messaging.
ERIC Educational Resources Information Center
Turner, Fay
1990-01-01
Discusses the interlibrary loan (ILL) protocol, a standard based on the principles of the Open Systems Interconnection (OSI) Reference Model. Benefits derived from protocol use are described, the status of the protocol as an international standard is reviewed, and steps taken by the National Library of Canada to facilitate migration to an ILL…
Bagchi, Sourav Kumar; Rao, Pavuluri Srinivasa; Mallick, Nirupama
2015-03-01
Drying of wet algal biomass is a major bottleneck in viable commercial production of the microalgal biodiesel. In the present investigation, an oven drying protocol was standardized for drying of wet Scenedesmus biomass at 60, 80 and 100°C with initial sample thickness of 5.0, 7.5 and 10.0mm. The optimum drying temperature was found to be 80°C with a maximum lipid yield of 425.0±5.9mgg(-1) at 15h drying time for 5.0mm thick samples with 0.033kWh power consumption. Partial drying at 80°C up to 10% residual moisture content was efficient showing 93% lipid recovery with 8h drying and a power consumption of 0.017kWh. Scenedesmus biomass was also found to be rich in saturated and mono-unsaturated fatty acids. Thus, the drying protocol demonstrates its suitability to improve the downstream processing of biodiesel production by significantly lowering the power consumption and the drying time. Copyright © 2014 Elsevier Ltd. All rights reserved.
Phuong, Nam Ngoc; Zalouk-Vergnoux, Aurore; Kamari, Abderrahmane; Mouneyrac, Catherine; Amiard, Frederic; Poirier, Laurence; Lagarde, Fabienne
2018-03-01
Microplastics (MPs) constitute a main environmental issue due to their threat to marine organisms and so far to humans. The lack of a fast standard protocol in MP isolation and identification from living organisms bring to challenge for the science. In this paper, an optimized protocol using potassium hydroxide 10% (KOH 10%; m/v) for digestion of mussel soft tissues (Mytilus edulis) and multi-steps of sedimentation has been developed. Efficiency higher than 99.9% of organic and mineral matter elimination was shown by application on mussels sampled on the French Atlantic coast. The identification of MPs was performed by FTIR microscopy straight on the filter and the whole analysis can be compatible with a routine goal. Fourteen MPs of four different chemical natures were found and identified in 5 pools of 3 sampled mussels. Their size ranged from 30 to 200 μm. Further investigations are now needed to evaluate the potential risk of such particles within this marine bivalve species and other filter feeders.
Ko, Dae-Hyun; Ji, Misuk; Kim, Sollip; Cho, Eun-Jung; Lee, Woochang; Yun, Yeo-Min; Chun, Sail; Min, Won-Ki
2016-01-01
The results of urine sediment analysis have been reported semiquantitatively. However, as recent guidelines recommend quantitative reporting of urine sediment, and with the development of automated urine sediment analyzers, there is an increasing need for quantitative analysis of urine sediment. Here, we developed a protocol for urine sediment analysis and quantified the results. Based on questionnaires, various reports, guidelines, and experimental results, we developed a protocol for urine sediment analysis. The results of this new protocol were compared with those obtained with a standardized chamber and an automated sediment analyzer. Reference intervals were also estimated using new protocol. We developed a protocol with centrifugation at 400 g for 5 min, with the average concentration factor of 30. The correlation between quantitative results of urine sediment analysis, the standardized chamber, and the automated sediment analyzer were generally good. The conversion factor derived from the new protocol showed a better fit with the results of manual count than the default conversion factor in the automated sediment analyzer. We developed a protocol for manual urine sediment analysis to quantitatively report the results. This protocol may provide a mean for standardization of urine sediment analysis.
Validity of Assessments of Youth Access to Tobacco: The Familiarity Effect
Landrine, Hope; Klonoff, Elizabeth A.
2003-01-01
Objectives. We examined the standard compliance protocol and its validity as a measure of youth access to tobacco. Methods. In Study 1, youth smokers reported buying cigarettes in stores where they are regular customers. In Study 2, youths attempted to purchase cigarettes by using the Standard Protocol, in which they appeared at stores once for cigarettes, and by using the Familiarity Protocol, in which they were rendered regular customers by purchasing nontobacco items 4 times and then requested cigarettes during their fifth visit. Results. Sales to youths aged 17 years in the Familiarity Protocol were significantly higher than sales to the same age group in the Standard Protocols (62.5% vs. 6%, respectively). Conclusions. The Standard Protocol does not match how youths obtain cigarettes. Access is low for stranger youths within compliance studies, but access is high for familiar youths outside of compliance studies. PMID:14600057
Cimino, Matthew T
2010-03-01
Twenty-four herbal dietary supplement powder and extract reference standards provided by the National Institute of Standards and Technology (NIST) were investigated using three different commercially available DNA extraction kits to evaluate DNA availability for downstream nucleotide-based applications. The material included samples of Camellia, Citrus, Ephedra, Ginkgo, Hypericum, Serenoa, And Vaccinium. Protocols from Qiagen, MoBio, and Phytopure were used to isolate and purify DNA from the NIST standards. The resulting DNA concentration was quantified using SYBR Green fluorometry. Each of the 24 samples yielded DNA, though the concentration of DNA from each approach was notably different. The Phytopure method consistently yielded more DNA. The average yield ratio was 22 : 3 : 1 (ng/microL; Phytopure : Qiagen : MoBio). Amplification of the internal transcribed spacer II region using PCR was ultimately successful in 22 of the 24 samples. Direct sequencing chromatograms of the amplified material suggested that most of the samples were comprised of mixtures. However, the sequencing chromatograms of 12 of the 24 samples were sufficient to confirm the identity of the target material. The successful extraction, amplification, and sequencing of DNA from these herbal dietary supplement extracts and powders supports a continued effort to explore nucleotide sequence-based tools for the authentication and identification of plants in dietary supplements. (c) Georg Thieme Verlag KG Stuttgart . New York.
Interpreting and Reporting Radiological Water-Quality Data
McCurdy, David E.; Garbarino, John R.; Mullin, Ann H.
2008-01-01
This document provides information to U.S. Geological Survey (USGS) Water Science Centers on interpreting and reporting radiological results for samples of environmental matrices, most notably water. The information provided is intended to be broadly useful throughout the United States, but it is recommended that scientists who work at sites containing radioactive hazardous wastes need to consult additional sources for more detailed information. The document is largely based on recognized national standards and guidance documents for radioanalytical sample processing, most notably the Multi-Agency Radiological Laboratory Analytical Protocols Manual (MARLAP), and on documents published by the U.S. Environmental Protection Agency and the American National Standards Institute. It does not include discussion of standard USGS practices including field quality-control sample analysis, interpretive report policies, and related issues, all of which shall always be included in any effort by the Water Science Centers. The use of 'shall' in this report signifies a policy requirement of the USGS Office of Water Quality.
Sepehrband, Farshid; O'Brien, Kieran; Barth, Markus
2017-12-01
Several diffusion-weighted MRI techniques have been developed and validated during the past 2 decades. While offering various neuroanatomical inferences, these techniques differ in their proposed optimal acquisition design, preventing clinicians and researchers benefiting from all potential inference methods, particularly when limited time is available. This study reports an optimal design that enables for a time-efficient diffusion-weighted MRI acquisition scheme at 7 Tesla. The primary audience of this article is the typical end user, interested in diffusion-weighted microstructural imaging at 7 Tesla. We tested b-values in the range of 700 to 3000 s/mm 2 with different number of angular diffusion-encoding samples, against a data-driven "gold standard." The suggested design is a protocol with b-values of 1000 and 2500 s/mm 2 , with 25 and 50 samples, uniformly distributed over two shells. We also report a range of protocols in which the results of fitting microstructural models to the diffusion-weighted data had high correlation with the gold standard. We estimated minimum acquisition requirements that enable diffusion tensor imaging, higher angular resolution diffusion-weighted imaging, neurite orientation dispersion, and density imaging and white matter tract integrity across whole brain with isotropic resolution of 1.8 mm in less than 11 min. Magn Reson Med 78:2170-2184, 2017. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.
Rough spacecraft surfaces -a threat to Planetary Protection issues
NASA Astrophysics Data System (ADS)
Probst, Alexander; Facius, Rainer; Wirth, Reinhard; Moissl-Eichinger, Christine
Inadvertent introduction of terrestrial microorganisms to foreign solar bodies could compromise the integrity of present and future life detection missions. For Planetary Protection purposes space agencies measure the aerobic, mesophilic spore load of a spacecraft as a proxy indicator in order to determine its bioload. Emerging novel hardware in space science implicates novel surface structures and materials that need to be controlled with regard to contaminations. For instance (roughened) carbon fiber reinforced plastic and Vectran fabric for construction of landing platforms and airbags, respectively, have been used in some Mars exploration missions. These materials have different levels of roughness and their potential risk to retain spores for insufficient sampling success has never been in scope of investigation. In this comprehensive study we evaluated ESA's novel nylon flocked swab protocol on stainless steel and other tech-nical surfaces with regard to Bacillus spore recovery. Low recovery efficiencies of the ESA standard wipe assay for large surface sampling were demonstrated with regard to Bacillus at-rophaeus spore detection. Therefore another protocol designed for rough surface sampling was evaluated on Vectran fabric and (roughened) carbon fiber reinforced plastic. Moreover, scan-ning electron micrographs of the technical surfaces studied allowed a more detailed view on their properties. The evaluated sampling protocols and the corresponding results are of high interest for future life detection missions in order to preserve their scientific integrity throughout spacecraft assembly.
Ge, Meili; Shao, Yingqi; Huang, Jinbo; Huang, Zhendong; Zhang, Jing; Nie, Neng; Zheng, Yizhou
2013-01-01
Background Previous reports showed that outcome of rabbit antithymocyte globulin (rATG) was not satisfactory as the first-line therapy for severe aplastic anemia (SAA). We explored a modifying schedule of administration of rATG. Design and Methods Outcomes of a cohort of 175 SAA patients, including 51 patients administered with standard protocol (3.55 mg/kg/d for 5 days) and 124 cases with optimized protocol (1.97 mg/kg/d for 9 days) of rATG plus cyclosporine (CSA), were analyzed retrospectively. Results Of all 175 patients, response rates at 3 and 6 months were 36.6% and 56.0%, respectively. 51 cases received standard protocol had poor responses at 3 (25.5%) and 6 months (41.2%). However, 124 patients received optimized protocol had better responses at 3 (41.1%, P = 0.14) and 6 (62.1%, P = 0.01). Higher incidences of infection (57.1% versus 37.9%, P = 0.02) and early mortality (17.9% versus 0.8%, P<0.001) occurred in patients received standard protocol compared with optimized protocol. The 5-year overall survival in favor of the optimized over standard rATG protocol (76.0% versus. 50.3%, P<0.001) was observed. By multivariate analysis, optimized protocol (RR = 2.21, P = 0.04), response at 3 months (RR = 10.31, P = 0.03) and shorter interval (<23 days) between diagnosis and initial dose of rATG (RR = 5.35, P = 0.002) were independent favorable predictors of overall survival. Conclusions Optimized instead of standard rATG protocol in combination with CSA remained efficacious as a first-line immunosuppressive regimen for SAA. PMID:23554855
Sampling protocol for monitoring abiotic and biotic characteristics of mountain ponds and lakes
Hoffman, Robert L.; Tyler, Torrey J.; Larson, Gary L.; Adams, Michael J.; Wente, Wendy; Galvan, Stephanie
2005-01-01
This document describes field techniques and procedures used for sampling mountain ponds and lakes. These techniques and procedures will be used primarily to monitor, as part of long-term programs in National Parks and other protected areas, the abiotic and biotic characteristics of naturally occurring permanent montane lentic systems up to 75 ha in surface area. However, the techniques and procedures described herein also can be used to sample temporary or ephemeral montane lentic sites. Each Standard Operating Procedure (SOP) section addresses a specific component of the limnological investigation, and describes in detail field sampling methods pertaining to parameters to be measured for each component.
Conformational free energies of methyl-α-L-iduronic and methyl-β-D-glucuronic acids in water
NASA Astrophysics Data System (ADS)
Babin, Volodymyr; Sagui, Celeste
2010-03-01
We present a simulation protocol that allows for efficient sampling of the degrees of freedom of a solute in explicit solvent. The protocol involves using a nonequilibrium umbrella sampling method, in this case, the recently developed adaptively biased molecular dynamics method, to compute an approximate free energy for the slow modes of the solute in explicit solvent. This approximate free energy is then used to set up a Hamiltonian replica exchange scheme that samples both from biased and unbiased distributions. The final accurate free energy is recovered via the weighted histogram analysis technique applied to all the replicas, and equilibrium properties of the solute are computed from the unbiased trajectory. We illustrate the approach by applying it to the study of the puckering landscapes of the methyl glycosides of α-L-iduronic acid and its C5 epimer β-D-glucuronic acid in water. Big savings in computational resources are gained in comparison to the standard parallel tempering method.
Conformational free energies of methyl-alpha-L-iduronic and methyl-beta-D-glucuronic acids in water.
Babin, Volodymyr; Sagui, Celeste
2010-03-14
We present a simulation protocol that allows for efficient sampling of the degrees of freedom of a solute in explicit solvent. The protocol involves using a nonequilibrium umbrella sampling method, in this case, the recently developed adaptively biased molecular dynamics method, to compute an approximate free energy for the slow modes of the solute in explicit solvent. This approximate free energy is then used to set up a Hamiltonian replica exchange scheme that samples both from biased and unbiased distributions. The final accurate free energy is recovered via the weighted histogram analysis technique applied to all the replicas, and equilibrium properties of the solute are computed from the unbiased trajectory. We illustrate the approach by applying it to the study of the puckering landscapes of the methyl glycosides of alpha-L-iduronic acid and its C5 epimer beta-D-glucuronic acid in water. Big savings in computational resources are gained in comparison to the standard parallel tempering method.
NASA Astrophysics Data System (ADS)
Wrable-Rose, Madeline; Primera-Pedrozo, Oliva M.; Pacheco-Londoño, Leonardo C.; Hernandez-Rivera, Samuel P.
2010-12-01
This research examines the surface contamination properties, trace sample preparation methodologies, detection systems response and generation of explosive contamination standards for trace detection systems. Homogeneous and reproducible sample preparation is relevant for trace detection of chemical threats, such as warfare agents, highly energetic materials (HEM) and toxic industrial chemicals. The objective of this research was to develop a technology capable of producing samples and standards of HEM with controlled size and distribution on a substrate to generate specimens that would reproduce real contamination conditions. The research activities included (1) a study of the properties of particles generated by two deposition techniques: sample smearing deposition and inkjet deposition, on gold-coated silicon, glass and stainless steel substrates; (2) characterization of composition, distribution and adhesion characteristics of deposits; (3) evaluation of accuracy and reproducibility for depositing neat highly energetic materials such as TNT, RDX and ammonium nitrate; (4) a study of HEM-surface interactions using FTIR-RAIRS; and (5) establishment of protocols for validation of surface concentration using destructive methods such as HPLC.
Sheehan, Barbara; Stetson, Peter; Bhatt, Ashish R; Field, Adele I; Patel, Chirag; Maisel, James Mark
2016-01-01
Background The process of documentation in electronic health records (EHRs) is known to be time consuming, inefficient, and cumbersome. The use of dictation coupled with manual transcription has become an increasingly common practice. In recent years, natural language processing (NLP)–enabled data capture has become a viable alternative for data entry. It enables the clinician to maintain control of the process and potentially reduce the documentation burden. The question remains how this NLP-enabled workflow will impact EHR usability and whether it can meet the structured data and other EHR requirements while enhancing the user’s experience. Objective The objective of this study is evaluate the comparative effectiveness of an NLP-enabled data capture method using dictation and data extraction from transcribed documents (NLP Entry) in terms of documentation time, documentation quality, and usability versus standard EHR keyboard-and-mouse data entry. Methods This formative study investigated the results of using 4 combinations of NLP Entry and Standard Entry methods (“protocols”) of EHR data capture. We compared a novel dictation-based protocol using MediSapien NLP (NLP-NLP) for structured data capture against a standard structured data capture protocol (Standard-Standard) as well as 2 novel hybrid protocols (NLP-Standard and Standard-NLP). The 31 participants included neurologists, cardiologists, and nephrologists. Participants generated 4 consultation or admission notes using 4 documentation protocols. We recorded the time on task, documentation quality (using the Physician Documentation Quality Instrument, PDQI-9), and usability of the documentation processes. Results A total of 118 notes were documented across the 3 subject areas. The NLP-NLP protocol required a median of 5.2 minutes per cardiology note, 7.3 minutes per nephrology note, and 8.5 minutes per neurology note compared with 16.9, 20.7, and 21.2 minutes, respectively, using the Standard-Standard protocol and 13.8, 21.3, and 18.7 minutes using the Standard-NLP protocol (1 of 2 hybrid methods). Using 8 out of 9 characteristics measured by the PDQI-9 instrument, the NLP-NLP protocol received a median quality score sum of 24.5; the Standard-Standard protocol received a median sum of 29; and the Standard-NLP protocol received a median sum of 29.5. The mean total score of the usability measure was 36.7 when the participants used the NLP-NLP protocol compared with 30.3 when they used the Standard-Standard protocol. Conclusions In this study, the feasibility of an approach to EHR data capture involving the application of NLP to transcribed dictation was demonstrated. This novel dictation-based approach has the potential to reduce the time required for documentation and improve usability while maintaining documentation quality. Future research will evaluate the NLP-based EHR data capture approach in a clinical setting. It is reasonable to assert that EHRs will increasingly use NLP-enabled data entry tools such as MediSapien NLP because they hold promise for enhancing the documentation process and end-user experience. PMID:27793791
Vitamin D deficiency in Europe: pandemic?12
Dowling, Kirsten G; Škrabáková, Zuzana; Gonzalez-Gross, Marcela; Valtueña, Jara; De Henauw, Stefaan; Moreno, Luis; Damsgaard, Camilla T; Michaelsen, Kim F; Mølgaard, Christian; Jorde, Rolf; Grimnes, Guri; Moschonis, George; Mavrogianni, Christina; Manios, Yannis; Thamm, Michael; Mensink, Gert BM; Rabenberg, Martina; Busch, Markus A; Cox, Lorna; Meadows, Sarah; Goldberg, Gail; Prentice, Ann; Dekker, Jacqueline M; Nijpels, Giel; Pilz, Stefan; Swart, Karin M; van Schoor, Natasja M; Lips, Paul; Eiriksdottir, Gudny; Gudnason, Vilmundur; Cotch, Mary Frances; Koskinen, Seppo; Lamberg-Allardt, Christel; Durazo-Arvizu, Ramon A; Sempos, Christopher T; Kiely, Mairead
2016-01-01
Background: Vitamin D deficiency has been described as being pandemic, but serum 25-hydroxyvitamin D [25(OH)D] distribution data for the European Union are of very variable quality. The NIH-led international Vitamin D Standardization Program (VDSP) has developed protocols for standardizing existing 25(OH)D values from national health/nutrition surveys. Objective: This study applied VDSP protocols to serum 25(OH)D data from representative childhood/teenage and adult/older adult European populations, representing a sizable geographical footprint, to better quantify the prevalence of vitamin D deficiency in Europe. Design: The VDSP protocols were applied in 14 population studies [reanalysis of subsets of serum 25(OH)D in 11 studies and complete analysis of all samples from 3 studies that had not previously measured it] by using certified liquid chromatography–tandem mass spectrometry on biobanked sera. These data were combined with standardized serum 25(OH)D data from 4 previously standardized studies (for a total n = 55,844). Prevalence estimates of vitamin D deficiency [using various serum 25(OH)D thresholds] were generated on the basis of standardized 25(OH)D data. Results: An overall pooled estimate, irrespective of age group, ethnic mix, and latitude of study populations, showed that 13.0% of the 55,844 European individuals had serum 25(OH)D concentrations <30 nmol/L on average in the year, with 17.7% and 8.3% in those sampled during the extended winter (October–March) and summer (April–November) periods, respectively. According to an alternate suggested definition of vitamin D deficiency (<50 nmol/L), the prevalence was 40.4%. Dark-skinned ethnic subgroups had much higher (3- to 71-fold) prevalence of serum 25(OH)D <30 nmol/L than did white populations. Conclusions: Vitamin D deficiency is evident throughout the European population at prevalence rates that are concerning and that require action from a public health perspective. What direction these strategies take will depend on European policy but should aim to ensure vitamin D intakes that are protective against vitamin D deficiency in the majority of the European population. PMID:26864360
Precise determination of triple Sr isotopes (δ⁸⁷Sr and δ⁸⁸Sr) using MC-ICP-MS.
Liu, Hou-Chun; You, Chen-Feng; Huang, Kuo-Fang; Chung, Chuan-Hsiung
2012-01-15
The non-traditional stable strontium (Sr) isotopes have received increasing attention recently as new geochemical tracers for studying Sr isotopic fractionation and source identification. This has been attributed to the advancement in multiple-collector inductively coupled plasma mass spectrometry (MC-ICP-MS), allows to determine precisely and simultaneously of the triple Sr isotopes. In this study, we applied a modified empirical external normalization (EEN) MC-ICPMS procedure for mass bias correction in Sr isotopic measurement using (92)Zr/(90)Zr. High-purity Zr Standard was spiked into sample solutions and the degree of fractionation was calculated off-line using an exponential law. The long-term external reproducibility for NIST SRM 987 δ(87)Sr and δ(88)Sr was better than 0.040‰ and 0.018‰ (2SD), respectively. The IAPSO standard seawater was used as a secondary standard to validate the analytical protocol and the absolute ratios measured were 0.709161±0.000018 for (87)Sr/(86)Sr, 0.177±0.021‰ for δ(87)Sr, and 0.370±0.026‰ for δ(88)Sr (2SD, n=7). These values are in good agreement with the literature data analyzed by thermal ionization mass spectrometry (TIMS) double spike technique. Rock standards, BHVO-2, BCR-2 and AGV-2 were also analyzed to validate the robustness of the methodology and showed identical results with literature data. Compared to previous (91)Zr/(90)Zr correction, we obtained improved results based on (92)Zr/(90)Zr, probably due to similar mass difference between (92)Zr/(90)Zr and measured Sr isotopes. The new analytical protocol presented in this study not only improves the analytical precision but also increases sample efficiency by omitting the use of the standard-sample bracketing (SSB) procedure. Copyright © 2011 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Boger, R. A.; Low, R.; Jaroensutasinee, M.; Jaroensutasinee, K.; Sparrow, E. B.; Costosa, J. I.; Medina, J.; Randolph, G.
2015-12-01
GLOBE in Thailand and GLOBE in Africa independently developed citizen science protocols for collecting and analyzing mosquito larvae. These protocols have been piloted in several workshops and implemented in schools. Data collected have been used for several secondary, undergraduate and graduate student research studies. Over this past year, 2015, these protocols have been synthesized into one protocol that will be made available to the world-wide community through the GLOBE website (www.globe.gov). This new protocol is designed to be flexible in the mosquito species that can be collected and the types of environments sampled (e.g., containers in and around the house, ponds, irrigation ditches in a rice paddy field). Plans are underway to enable web-based data entry and mobile apps for data collection and submission. Once everything is finalized, a GLOBE field campaign will be initiated for citizen scientists to collect meaningful data on where different types of mosquito larvae are found and how the abundance and distribution is changing seasonally. To assist in the standardization of data collection and quality control, training slides are being developed and will be made available in early 2016. This will enable a wider participation of citizen scientists to participate in this effort to collect mosquito data by making it easier to become part of the GLOBE community. As with mosquito larvae, training slides are being created for hydrosphere, biosphere, atmosphere, and pedosphere GLOBE measurement protocols. The development of the mosquito protocol and the training slides are in direct response to the GLOBE community's desire to increase citizen science participation beyond primary and secondary schools, in observing and measuring environmental change.
Emwas, Abdul-Hamid; Luchinat, Claudio; Turano, Paola; Tenori, Leonardo; Roy, Raja; Salek, Reza M; Ryan, Danielle; Merzaban, Jasmeen S; Kaddurah-Daouk, Rima; Zeri, Ana Carolina; Nagana Gowda, G A; Raftery, Daniel; Wang, Yulan; Brennan, Lorraine; Wishart, David S
The metabolic composition of human biofluids can provide important diagnostic and prognostic information. Among the biofluids most commonly analyzed in metabolomic studies, urine appears to be particularly useful. It is abundant, readily available, easily stored and can be collected by simple, noninvasive techniques. Moreover, given its chemical complexity, urine is particularly rich in potential disease biomarkers. This makes it an ideal biofluid for detecting or monitoring disease processes. Among the metabolomic tools available for urine analysis, NMR spectroscopy has proven to be particularly well-suited, because the technique is highly reproducible and requires minimal sample handling. As it permits the identification and quantification of a wide range of compounds, independent of their chemical properties, NMR spectroscopy has been frequently used to detect or discover disease fingerprints and biomarkers in urine. Although protocols for NMR data acquisition and processing have been standardized, no consensus on protocols for urine sample selection, collection, storage and preparation in NMR-based metabolomic studies have been developed. This lack of consensus may be leading to spurious biomarkers being reported and may account for a general lack of reproducibility between laboratories. Here, we review a large number of published studies on NMR-based urine metabolic profiling with the aim of identifying key variables that may affect the results of metabolomics studies. From this survey, we identify a number of issues that require either standardization or careful accounting in experimental design and provide some recommendations for urine collection, sample preparation and data acquisition.
Nebbak, A; El Hamzaoui, B; Berenger, J-M; Bitam, I; Raoult, D; Almeras, L; Parola, P
2017-12-01
Ticks and fleas are vectors for numerous human and animal pathogens. Controlling them, which is important in combating such diseases, requires accurate identification, to distinguish between vector and non-vector species. Recently, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) was applied to the rapid identification of arthropods. The growth of this promising tool, however, requires guidelines to be established. To this end, standardization protocols were applied to species of Rhipicephalus sanguineus (Ixodida: Ixodidae) Latreille and Ctenocephalides felis felis (Siphonaptera: Pulicidae) Bouché, including the automation of sample homogenization using two homogenizer devices, and varied sample preservation modes for a period of 1-6 months. The MS spectra were then compared with those obtained from manual pestle grinding, the standard homogenization method. Both automated methods generated intense, reproducible MS spectra from fresh specimens. Frozen storage methods appeared to represent the best preservation mode, for up to 6 months, while storage in ethanol is also possible, with some caveats for tick specimens. Carnoy's buffer, however, was shown to be less compatible with MS analysis for the purpose of identifying ticks or fleas. These standard protocols for MALDI-TOF MS arthropod identification should be complemented by additional MS spectrum quality controls, to generalize their use in monitoring arthropods of medical interest. © 2017 The Royal Entomological Society.
Interoperability in the Planetary Science Archive (PSA)
NASA Astrophysics Data System (ADS)
Rios Diaz, C.
2017-09-01
The protocols and standards currently being supported by the recently released new version of the Planetary Science Archive at this time are the Planetary Data Access Protocol (PDAP), the EuroPlanet- Table Access Protocol (EPN-TAP) and Open Geospatial Consortium (OGC) standards. We explore these protocols in more detail providing scientifically useful examples of their usage within the PSA.
1994-09-01
vi A b stract...5-2 Proposed Decision Tree for ACJC Abatement Activities 5-10 Vi AFIT/GEE/ENV/94S-23 ABSTRACT This study investigated the differing regulatory...specific amount. According to 29 CFR 1910.58(k)(2)( vi )(B), labeling provisions do not apply unless asbestos is present in a product in concentrations
Land use change monitoring in Maryland using a probabilistic sample and rapid photointerpretation
Tonya Lister; Andrew Lister; Eunice Alexander
2014-01-01
The U.S. state of Maryland needs to monitor land use change in order to address land management objectives. This paper presents a change detection method that, through automation and standard geographic information system (GIS) techniques, facilitates the estimation of landscape change via photointerpretation. Using the protocols developed, we show a net loss of forest...
A randomized trial of protocol-based care for early septic shock.
Yealy, Donald M; Kellum, John A; Huang, David T; Barnato, Amber E; Weissfeld, Lisa A; Pike, Francis; Terndrup, Thomas; Wang, Henry E; Hou, Peter C; LoVecchio, Frank; Filbin, Michael R; Shapiro, Nathan I; Angus, Derek C
2014-05-01
In a single-center study published more than a decade ago involving patients presenting to the emergency department with severe sepsis and septic shock, mortality was markedly lower among those who were treated according to a 6-hour protocol of early goal-directed therapy (EGDT), in which intravenous fluids, vasopressors, inotropes, and blood transfusions were adjusted to reach central hemodynamic targets, than among those receiving usual care. We conducted a trial to determine whether these findings were generalizable and whether all aspects of the protocol were necessary. In 31 emergency departments in the United States, we randomly assigned patients with septic shock to one of three groups for 6 hours of resuscitation: protocol-based EGDT; protocol-based standard therapy that did not require the placement of a central venous catheter, administration of inotropes, or blood transfusions; or usual care. The primary end point was 60-day in-hospital mortality. We tested sequentially whether protocol-based care (EGDT and standard-therapy groups combined) was superior to usual care and whether protocol-based EGDT was superior to protocol-based standard therapy. Secondary outcomes included longer-term mortality and the need for organ support. We enrolled 1341 patients, of whom 439 were randomly assigned to protocol-based EGDT, 446 to protocol-based standard therapy, and 456 to usual care. Resuscitation strategies differed significantly with respect to the monitoring of central venous pressure and oxygen and the use of intravenous fluids, vasopressors, inotropes, and blood transfusions. By 60 days, there were 92 deaths in the protocol-based EGDT group (21.0%), 81 in the protocol-based standard-therapy group (18.2%), and 86 in the usual-care group (18.9%) (relative risk with protocol-based therapy vs. usual care, 1.04; 95% confidence interval [CI], 0.82 to 1.31; P=0.83; relative risk with protocol-based EGDT vs. protocol-based standard therapy, 1.15; 95% CI, 0.88 to 1.51; P=0.31). There were no significant differences in 90-day mortality, 1-year mortality, or the need for organ support. In a multicenter trial conducted in the tertiary care setting, protocol-based resuscitation of patients in whom septic shock was diagnosed in the emergency department did not improve outcomes. (Funded by the National Institute of General Medical Sciences; ProCESS ClinicalTrials.gov number, NCT00510835.).
Campi-Azevedo, Ana Carolina; Peruhype-Magalhães, Vanessa; Coelho-Dos-Reis, Jordana Grazziela; Costa-Pereira, Christiane; Yamamura, Anna Yoshida; Lima, Sheila Maria Barbosa de; Simões, Marisol; Campos, Fernanda Magalhães Freire; de Castro Zacche Tonini, Aline; Lemos, Elenice Moreira; Brum, Ricardo Cristiano; de Noronha, Tatiana Guimarães; Freire, Marcos Silva; Maia, Maria de Lourdes Sousa; Camacho, Luiz Antônio Bastos; Rios, Maria; Chancey, Caren; Romano, Alessandro; Domingues, Carla Magda; Teixeira-Carvalho, Andréa; Martins-Filho, Olindo Assis
2017-09-01
Technological innovations in vaccinology have recently contributed to bring about novel insights for the vaccine-induced immune response. While the current protocols that use peripheral blood samples may provide abundant data, a range of distinct components of whole blood samples are required and the different anticoagulant systems employed may impair some properties of the biological sample and interfere with functional assays. Although the interference of heparin in functional assays for viral neutralizing antibodies such as the functional plaque-reduction neutralization test (PRNT), considered the gold-standard method to assess and monitor the protective immunity induced by the Yellow fever virus (YFV) vaccine, has been well characterized, the development of pre-analytical treatments is still required for the establishment of optimized protocols. The present study intended to optimize and evaluate the performance of pre-analytical treatment of heparin-collected blood samples with ecteola-cellulose (ECT) to provide accurate measurement of anti-YFV neutralizing antibodies, by PRNT. The study was designed in three steps, including: I. Problem statement; II. Pre-analytical steps; III. Analytical steps. Data confirmed the interference of heparin on PRNT reactivity in a dose-responsive fashion. Distinct sets of conditions for ECT pre-treatment were tested to optimize the heparin removal. The optimized protocol was pre-validated to determine the effectiveness of heparin plasma:ECT treatment to restore the PRNT titers as compared to serum samples. The validation and comparative performance was carried out by using a large range of serum vs heparin plasma:ECT 1:2 paired samples obtained from unvaccinated and 17DD-YFV primary vaccinated subjects. Altogether, the findings support the use of heparin plasma:ECT samples for accurate measurement of anti-YFV neutralizing antibodies. Copyright © 2017 Elsevier B.V. All rights reserved.
One Approach for Transitioning the iNET Standards into the IRIG 106 Telemetry Standards
2015-05-26
Protocol Suite. Figure 1 illustrates the Open Systems Interconnection ( OSI ) Model, the corresponding TCP/IP Model, and the major components of the TCP...IP Protocol Suite. Figure 2 represents the iNET-specific protocols layered onto the TCP/IP Model. Figure 1. OSI and TCP/IP Model with TCP/IP...Protocol Suite TCP/IP Protocol Suite Major Components IPv4 IPv6 TCP/IP Model OSI Model Application Presentation
Tobe, Shanan S; Bailey, Stuart; Govan, James; Welch, Lindsey A
2013-03-01
Although poaching is a common wildlife crime, the high and prohibitive cost of specialised animal testing means that many cases are left un-investigated. We previously described a novel approach to wildlife crime investigation that looked at the identification of human DNA on poached animal remains (Tobe, Govan and Welch, 2011). Human DNA was successfully isolated and amplified from simulated poaching incidents, however a low template protocol was required which made this method unsuitable for use in many laboratories. We now report on an optimised recovery and amplification protocol which removes the need for low template analysis. Samples from 10 deer (40 samples total - one from each leg) analysed in the original study were re-analysed in the current study with an additional 11 deer samples. Four samples analysed using Chelex did not show any results and a new method was devised whereby the available DNA was concentrated. By combining the DNA extracts from all tapings of the same deer remains followed by concentration, the recovered quantity of human DNA was found to be 29.5pg±43.2pg, 31× greater than the previous study. The use of the Investigator Decaplex SE (QIAGEN) STR kit provided better results in the form of more complete profiles than did the AmpFℓSTR® SGM Plus® kit at 30cycles (Applied Biosystems). Re-analysis of the samples from the initial study using the new, optimised protocol resulted in an average increase of 18% of recovered alleles. Over 17 samples, 71% of the samples analysed using the optimised protocol showed sufficient amplification for comparison to a reference profile and gave match probabilities ranging from 7.7690×10(-05) to 2.2706×10(-14). The removal of low template analysis means this optimised method provides evidence of high probative value and is suitable for immediate use in forensic laboratories. All methods and techniques used are standard and are compatible with current SOPs. As no high cost non-human DNA analysis is required the overall process is no more expensive than the investigation of other volume crime samples. The technique is suitable for immediate use in poaching incidents. Copyright © 2012 Forensic Science Society. Published by Elsevier Ireland Ltd. All rights reserved.
Hafeez, Baria; Paolicchi, Juliann; Pon, Steven; Howell, Joy D; Grinspan, Zachary M
2016-05-01
Status epilepticus is a common neurologic emergency in children. Pediatric medical centers often develop protocols to standardize care. Widespread adoption of electronic health records by hospitals affords the opportunity for clinicians to rapidly, and electronically evaluate protocol adherence. We reviewed the clinical data of a small sample of 7 children with status epilepticus, in order to (1) qualitatively determine the feasibility of automated data extraction and (2) demonstrate a timeline-style visualization of each patient's first 24 hours of care. Qualitatively, our observations indicate that most clinical data are well labeled in structured fields within the electronic health record, though some important information, particularly electroencephalography (EEG) data, may require manual abstraction. We conclude that a visualization that clarifies a patient's clinical course can be automatically created using the patient's electronic clinical data, supplemented with some manually abstracted data. Future work could use this timeline to evaluate adherence to status epilepticus clinical protocols. © The Author(s) 2015.
Sud, Manish; Fahy, Eoin; Cotter, Dawn; Azam, Kenan; Vadivelu, Ilango; Burant, Charles; Edison, Arthur; Fiehn, Oliver; Higashi, Richard; Nair, K Sreekumaran; Sumner, Susan; Subramaniam, Shankar
2016-01-04
The Metabolomics Workbench, available at www.metabolomicsworkbench.org, is a public repository for metabolomics metadata and experimental data spanning various species and experimental platforms, metabolite standards, metabolite structures, protocols, tutorials, and training material and other educational resources. It provides a computational platform to integrate, analyze, track, deposit and disseminate large volumes of heterogeneous data from a wide variety of metabolomics studies including mass spectrometry (MS) and nuclear magnetic resonance spectrometry (NMR) data spanning over 20 different species covering all the major taxonomic categories including humans and other mammals, plants, insects, invertebrates and microorganisms. Additionally, a number of protocols are provided for a range of metabolite classes, sample types, and both MS and NMR-based studies, along with a metabolite structure database. The metabolites characterized in the studies available on the Metabolomics Workbench are linked to chemical structures in the metabolite structure database to facilitate comparative analysis across studies. The Metabolomics Workbench, part of the data coordinating effort of the National Institute of Health (NIH) Common Fund's Metabolomics Program, provides data from the Common Fund's Metabolomics Resource Cores, metabolite standards, and analysis tools to the wider metabolomics community and seeks data depositions from metabolomics researchers across the world. © The Author(s) 2015. Published by Oxford University Press on behalf of Nucleic Acids Research.
Elliott, Paul; Peakman, Tim C
2008-04-01
UK Biobank is a large prospective study in the UK to investigate the role of genetic factors, environmental exposures and lifestyle in the causes of major diseases of late and middle age. Extensive data and biological samples are being collected from 500,000 participants aged between 40 and 69 years. The biological samples that are collected and how they are processed and stored will have a major impact on the future scientific usefulness of the UK Biobank resource. The aim of the UK Biobank sample handling and storage protocol is to specify methods for the collection and storage of participant samples that give maximum scientific return within the available budget. Processing or storage methods that, as far as can be predicted, will preclude current or future assays have been avoided. The protocol was developed through a review of the literature on sample handling and processing, wide consultation within the academic community and peer review. Protocol development addressed which samples should be collected, how and when they should be processed and how the processed samples should be stored to ensure their long-term integrity. The recommended protocol was extensively tested in a series of validation studies. UK Biobank collects about 45 ml blood and 9 ml of urine with minimal local processing from each participant using the vacutainer system. A variety of preservatives, anti-coagulants and clot accelerators is used appropriate to the expected end use of the samples. Collection of other material (hair, nails, saliva and faeces) was also considered but rejected for the full cohort. Blood and urine samples from participants are transported overnight by commercial courier to a central laboratory where they are processed and aliquots of urine, plasma, serum, white cells and red cells stored in ultra-low temperature archives. Aliquots of whole blood are also stored for potential future production of immortalized cell lines. A standard panel of haematology assays is completed on whole blood from all participants, since such assays need to be conducted on fresh samples (whereas other assays can be done on stored samples). By the end of the recruitment phase, 15 million sample aliquots will be stored in two geographically separate archives: 9.5 million in a -80 degrees C automated archive and 5.5 million in a manual liquid nitrogen archive at -180 degrees C. Because of the size of the study and the numbers of samples obtained from participants, the protocol stipulates a highly automated approach for the processing and storage of samples. Implementation of the processes, technology, systems and facilities has followed best practices used in manufacturing industry to reduce project risk and to build in quality and robustness. The data produced from sample collection, processing and storage are highly complex and are managed by a commercially available LIMS system fully integrated with the entire process. The sample handling and storage protocol adopted by UK Biobank provides quality assured and validated methods that are feasible within the available funding and reflect the size and aims of the project. Experience from recruiting and processing the first 40,000 participants to the study demonstrates that the adopted methods and technologies are fit-for-purpose and robust.
Evaluation of Protocol Uniformity Concerning Laparoscopic Cholecystectomy in The Netherlands
Goossens, Richard H. M.; van Eijk, Daan J.; Lange, Johan F.
2008-01-01
Background Iatrogenic bile duct injury remains a current complication of laparoscopic cholecystectomy. One uniform and standardized protocol, based on the “critical view of safety” concept of Strasberg, should reduce the incidence of this complication. Furthermore, owing to the rapid development of minimally invasive surgery, technicians are becoming more frequently involved. To improve communication between the operating team and technicians, standardized actions should also be defined. The aim of this study was to compare existing protocols for laparoscopic cholecystectomy from various Dutch hospitals. Methods Fifteen Dutch hospitals were contacted for evaluation of their protocols for laparoscopic cholecystectomy. All evaluated protocols were divided into six steps and were compared accordingly. Results In total, 13 hospitals responded—5 academic hospitals, 5 teaching hospitals, 3 community hospitals—of which 10 protocols were usable for comparison. Concerning the trocar positions, only minor differences were found. The concept of “critical view of safety” was represented in just one protocol. Furthermore, the order of clipping and cutting the cystic artery and duct differed. Descriptions of instruments and apparatus were also inconsistent. Conclusions Present protocols differ too much to define a universal procedure among surgeons in The Netherlands. The authors propose one (inter)national standardized protocol, including standardized actions. This uniform standardized protocol has to be officially released and recommended by national scientific associations (e.g., the Dutch Society of Surgery) or international societies (e.g., European Association for Endoscopic Surgery and Society of American Gastrointestinal and Endoscopic Surgeons). The aim is to improve patient safety and professional communication, which are necessary for new developments. PMID:18224485
Delefortrie, Quentin; Schatt, Patricia; Grimmelprez, Alexandre; Gohy, Patrick; Deltour, Didier; Collard, Geneviève; Vankerkhoven, Patrick
2016-02-01
Although colonoscopy associated with histopathological sampling remains the gold standard in the diagnostic and follow-up of inflammatory bowel disease (IBD), calprotectin is becoming an essential biomarker in gastroenterology. The aim of this work is to compare a newly developed kit (Liaison® Calprotectin - Diasorin®) and its two distinct extraction protocols (weighing and extraction device protocol) with a well established point of care test (Quantum Blue® - Bühlmann-Alere®) in terms of analytical performances and ability to detect relapses amongst a Crohn's population in follow-up. Stool specimens were collected over a six month period and were composed of control and Crohn's patients. Amongst the Crohn's population disease activity (active vs quiescent) was evaluated by gastroenterologists. A significant difference was found between all three procedures in terms of calprotectin measurements (weighing protocol=30.3μg/g (median); stool extraction device protocol=36.9μg/g (median); Quantum Blue® (median)=63; Friedman test, P value=0.05). However, a good correlation was found between both extraction methods coupled with the Liaison® analyzer and between the Quantum Blue® (weighing protocol/extraction device protocol Rs=0.844, P=0.01; Quantum Blue®/extraction device protocol Rs=0.708, P=0.01; Quantum Blue®/weighing protocol, Rs=0.808, P=0.01). Finally, optimal cut-offs (and associated negative predictive values - NPV) for detecting relapses were in accordance with above results (Quantum Blue® 183.5μg/g and NPV of 100%>extraction device protocol+Liaison® analyzer 124.5μg/g and NPV of 93.5%>weighing protocol+Liaison® analyzer 106.5μg/g and NPV of 95%). Although all three methods correlated well and had relatively good NPV in terms of detecting relapses amongst a Crohn's population in follow-up, the lack of any international standard is the origin of different optimal cut-offs between the three procedures. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Šedo, Ondrej; Nemec, Alexandr; Křížová, Lenka; Kačalová, Magdaléna; Zdráhal, Zbyněk
2013-12-01
MALDI-TOF MS is currently becoming the method of choice for rapid identification of bacterial species in routine diagnostics. Yet, this method suffers from the inability to differentiate reliably between some closely related bacterial species including those of the Acinetobacter calcoaceticus-Acinetobacter baumannii (ACB) complex, namely A. baumannii and Acinetobacter nosocomialis. In the present study, we evaluated a protocol which was different from that used in the Bruker Daltonics identification system (MALDI BioTyper) to improve species identification using a taxonomically precisely defined set of 105 strains representing the four validly named species of the ACB complex. The novel protocol is based on the change in matrix composition from alpha-cyano-4-hydroxycinnamic acid (saturated solution in water:acetonitrile:trifluoroacetic acid, 47.5:50:2.5, v/v) to ferulic acid (12.5mgml(-1) solution in water:acetonitrile:formic acid 50:33:17, v/v), while the other steps of sample processing remain unchanged. Compared to the standard protocol, the novel one extended the range of detected compounds towards higher molecular weight, produced signals with better mass resolution, and allowed the detection of species-specific signals. As a result, differentiation of A. nosocomialis and A. baumannii strains by cluster analysis was improved and 13 A. nosocomialis strains, assigned erroneously or ambiguously by using the standard protocol, were correctly identified. Copyright © 2013 Elsevier GmbH. All rights reserved.
Telemetry Standards, RCC Standard 106-17. Chapter 21. Telemetry Network Standard Introduction
2017-07-01
Critical RF radio frequency RFC Request for Comment SNMP Simple Network Management Protocol TA test article TCP Transmission Control Protocol...chapters might be of most interest for a particular reader. In order to guide the reader toward the chapters of further interest , the applicable... Simple Network Management Protocol (SNMP) to pass management information through the system. The SNMP management information bases (MIBs) provide
Dentinger, Bryn T M; Margaritescu, Simona; Moncalvo, Jean-Marc
2010-07-01
We present two methods for DNA extraction from fresh and dried mushrooms that are adaptable to high-throughput sequencing initiatives, such as DNA barcoding. Our results show that these protocols yield ∼85% sequencing success from recently collected materials. Tests with both recent (<2 year) and older (>100 years) specimens reveal that older collections have low success rates and may be an inefficient resource for populating a barcode database. However, our method of extracting DNA from herbarium samples using small amount of tissue is reliable and could be used for important historical specimens. The application of these protocols greatly reduces time, and therefore cost, of generating DNA sequences from mushrooms and other fungi vs. traditional extraction methods. The efficiency of these methods illustrates that standardization and streamlining of sample processing should be shifted from the laboratory to the field. © 2009 Blackwell Publishing Ltd.
Lethal cardiac amyloidosis: Modification of the Congo Red technique on a forensic case.
Rancati, A; Andreola, S; Bailo, P; Boracchi, M; Fociani, P; Gentile, G; Zoja, R
2018-05-26
Congo Red staining is usually used in diagnosing amyloidosis, a pathology characterized by the storage of abnormal proteins in several human organs. When assessed on samples fixated in formalin and embended in paraffin, this staining can undergo several artefacts, causing diagnostic and interpretative difficulties due to its weak stainability and a consequent reduced visibility of the amyloid. These complications, in time, requested several variations of this staining technique, especially in clinical practice, while in the forensic field no protocols has ever been adapted to cadaveric samples, a material that is already characteristically burdened by a peculiar stainability. In our work, studying a sudden death caused by cardiac amyloidosis and diagnosed only with post-mortem exams, we present a modified Congo Red staining used with the purpose to demonstrate amyloid in cadaveric material after the unsuccessfully use of all standard protocols. Copyright © 2018. Published by Elsevier B.V.
Martos, Laura; Fernández-Pardo, Álvaro; Oto, Julia; Medina, Pilar; España, Francisco; Navarro, Silvia
2017-01-01
microRNAs are promising biomarkers in biological fluids in several diseases. Different plasma RNA isolation protocols and carriers are available, but their efficiencies have been scarcely compared. Plasma microRNAs were isolated using a phenol and column-based procedure and a column-based procedure, in the presence or absence of two RNA carriers (yeast RNA and MS2 RNA). We evaluated the presence of PCR inhibitors and the relative abundance of certain microRNAs by qRT-PCR. Furthermore, we analyzed the association between different isolation protocols, the relative abundance of the miRNAs in the sample, the GC content and the free energy of microRNAs. In all microRNAs analyzed, the addition of yeast RNA as a carrier in the different isolation protocols used gave lower raw Cq values, indicating higher microRNA recovery. Moreover, this increase in microRNAs recovery was dependent on their own relative abundance in the sample, their GC content and the free-energy of their own most stable secondary structure. Furthermore, the normalization of microRNA levels by an endogenous microRNA is more reliable than the normalization by plasma volume, as it reduced the difference in microRNA fold abundance between the different isolation protocols evaluated. Our thorough study indicates that a standardization of pre- and analytical conditions is necessary to obtain reproducible inter-laboratory results in plasma microRNA studies. PMID:29077772
Chung, K Y; Carter, G J; Stancliffe, J D
1999-02-01
A new European/International Standard (ISOprEN 10882-1) on the sampling of airborne particulates generated during welding and allied processes has been proposed. The use of a number of samplers and sampling procedures is allowable within the defined protocol. The influence of these variables on welding fume exposures measured during welding and grinding of stainless and mild steel using the gas metal arc (GMA) and flux-cored arc (FCA) and GMA welding of aluminium has been examined. Results show that use of any of the samplers will not give significantly different measured exposures. The effect on exposure measurement of placing the samplers on either side of the head was variable; consequently, sampling position cannot be meaningfully defined. All samplers collected significant amounts of grinding dust. Therefore, gravimetric determination of welding fume exposure in atmospheres containing grinding dust will be inaccurate. The use of a new size selective sampler can, to some extent, be used to give a more accurate estimate of exposure. The reliability of fume analysis data of welding consumables has caused concern; and the reason for differences that existed between the material safety data sheet and the analysis of fume samples collected requires further investigation.
Use of probability analysis to establish routine bioassay screening levels
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carbaugh, E.H.; Sula, M.J.; McFadden, K.M.
1990-09-01
Probability analysis was used by the Hanford Internal Dosimetry Program to establish bioassay screening levels for tritium and uranium in urine. Background environmental levels of these two radionuclides are generally detectable by the highly sensitive urine analysis procedures routinely used at Hanford. Establishing screening levels requires balancing the impact of false detection with the consequence of potentially undetectable occupation dose. To establish the screening levels, tritium and uranium analyses were performed on urine samples collected from workers exposed only to environmental sources. All samples were collected at home using a simulated 12-hour protocol for tritium and a simulated 24-hour collectionmore » protocol for uranium. Results of the analyses of these samples were ranked according to tritium concentration or total sample uranium. The cumulative percentile was calculated and plotted using log-probability coordinates. Geometric means and screening levels corresponding to various percentiles were estimated by graphical interpolation and standard calculations. The potentially annual internal dose associated with a screening level was calculated. Screening levels were selected corresponding to the 99.9 percentile, implying that, on the average, 1 out of 1000 samples collected from an unexposed worker population would be expected to exceed the screening level. 4 refs., 2 figs.« less
Trépout, Sylvain; Bastin, Philippe; Marco, Sergio
2017-03-12
This report describes a protocol for preparing thick biological specimens for further observation using a scanning transmission electron microscope. It also describes an imaging method for studying the 3D structure of thick biological specimens by scanning transmission electron tomography. The sample preparation protocol is based on conventional methods in which the sample is fixed using chemical agents, treated with a heavy atom salt contrasting agent, dehydrated in a series of ethanol baths, and embedded in resin. The specific imaging conditions for observing thick samples by scanning transmission electron microscopy are then described. Sections of the sample are observed using a through-focus method involving the collection of several images at various focal planes. This enables the recovery of in-focus information at various heights throughout the sample. This particular collection pattern is performed at each tilt angle during tomography data collection. A single image is then generated, merging the in-focus information from all the different focal planes. A classic tilt-series dataset is then generated. The advantage of the method is that the tilt-series alignment and reconstruction can be performed using standard tools. The collection of through-focal images allows the reconstruction of a 3D volume that contains all of the structural details of the sample in focus.
Automated standardization technique for an inductively-coupled plasma emission spectrometer
Garbarino, John R.; Taylor, Howard E.
1982-01-01
The manifold assembly subsystem described permits real-time computer-controlled standardization and quality control of a commercial inductively-coupled plasma atomic emission spectrometer. The manifold assembly consists of a branch-structured glass manifold, a series of microcomputer-controlled solenoid valves, and a reservoir for each standard. Automated standardization involves selective actuation of each solenoid valve that permits a specific mixed standard solution to be pumped to the nebulizer of the spectrometer. Quality control is based on the evaluation of results obtained for a mixed standard containing 17 analytes, that is measured periodically with unknown samples. An inaccurate standard evaluation triggers restandardization of the instrument according to a predetermined protocol. Interaction of the computer-controlled manifold assembly hardware with the spectrometer system is outlined. Evaluation of the automated standardization system with respect to reliability, simplicity, flexibility, and efficiency is compared to the manual procedure. ?? 1982.
Gonzalez, Susana; Yu, Woojin M.; Smith, Michael S.; Slack, Kristen N.; Rotterdam, Heidrun; Abrams, Julian A.; Lightdale, Charles J.
2011-01-01
Background Several types of forceps are available for use in sampling Barrett’s esophagus (BE). Few data exist with regard to biopsy quality for histologic assessment. Objective To evaluate sampling quality of 3 different forceps in patients with BE. Design Single-center, randomized clinical trial. Patients Consecutive patients with BE undergoing upper endoscopy. Interventions Patients randomized to have biopsy specimens taken with 1 of 3 types of forceps: standard, large capacity, or jumbo. Main Outcome Measurements Specimen adequacy was defined a priori as a well-oriented biopsy sample 2 mm or greater in diameter and with at least muscularis mucosa present. Results A total of 65 patients were enrolled and analyzed (standard forceps, n = 21; large-capacity forceps, n = 21; jumbo forceps, n = 23). Compared with jumbo forceps, a significantly higher proportion of biopsy samples with large-capacity forceps were adequate (37.8% vs 25.2%, P = .002). Of the standard forceps biopsy samples, 31.9% were adequate, which was not significantly different from specimens taken with large-capacity (P = .20) or jumbo (P = .09) forceps. Biopsy specimens taken with jumbo forceps had the largest diameter (median, 3.0 mm vs 2.5 mm [standard] vs 2.8 mm [large capacity]; P = .0001). However, jumbo forceps had the lowest proportion of specimens that were well oriented (overall P = .001). Limitations Heterogeneous patient population precluded dysplasia detection analyses. Conclusions Our results challenge the requirement of jumbo forceps and therapeutic endoscopes to properly perform the Seattle protocol. We found that standard and large-capacity forceps used with standard upper endoscopes produced biopsy samples at least as adequate as those obtained with jumbo forceps and therapeutic endoscopes in patients with BE. PMID:21034895
DOE Office of Scientific and Technical Information (OSTI.GOV)
Drzymala, R; Alvarez, P; Bednarz, G
2015-06-15
Purpose: The purpose of this multi-institutional study was to compare two new gamma stereotactic radiosurgery (GSRS) dosimetry protocols to existing calibration methods. The ultimate goal was to guide AAPM Task Group 178 in recommending a standard GSRS dosimetry protocol. Methods: Nine centers (ten GSRS units) participated in the study. Each institution made eight sets of dose rate measurements: six with two different ionization chambers in three different 160mm-diameter spherical phantoms (ABS plastic, Solid Water and liquid water), and two using the same ionization chambers with a custom in-air positioning jig. Absolute dose rates were calculated using a newly proposed formalismmore » by the IAEA working group for small and non-standard radiation fields and with a new air-kerma based protocol. The new IAEA protocol requires an in-water ionization chamber calibration and uses previously reported Monte-Carlo generated factors to account for the material composition of the phantom, the type of ionization chamber, and the unique GSRS beam configuration. Results obtained with the new dose calibration protocols were compared to dose rates determined by the AAPM TG-21 and TG-51 protocols, with TG-21 considered as the standard. Results: Averaged over all institutions, ionization chambers and phantoms, the mean dose rate determined with the new IAEA protocol relative to that determined with TG-21 in the ABS phantom was 1.000 with a standard deviation of 0.008. For TG-51, the average ratio was 0.991 with a standard deviation of 0.013, and for the new in-air formalism it was 1.008 with a standard deviation of 0.012. Conclusion: Average results with both of the new protocols agreed with TG-21 to within one standard deviation. TG-51, which does not take into account the unique GSRS beam configuration or phantom material, was not expected to perform as well as the new protocols. The new IAEA protocol showed remarkably good agreement with TG-21. Conflict of Interests: Paula Petti, Josef Novotny, Gennady Neyman and Steve Goetsch are consultants for Elekta Instrument A/B; Elekta Instrument AB, PTW Freiburg GmbH, Standard Imaging, Inc., and The Phantom Laboratory, Inc. loaned equipment for use in these experiments; The University of Wisconsin Accredited Dosimetry Calibration Laboratory provided calibration services.« less
A Standard Mutual Authentication Protocol for Cloud Computing Based Health Care System.
Mohit, Prerna; Amin, Ruhul; Karati, Arijit; Biswas, G P; Khan, Muhammad Khurram
2017-04-01
Telecare Medical Information System (TMIS) supports a standard platform to the patient for getting necessary medical treatment from the doctor(s) via Internet communication. Security protection is important for medical records (data) of the patients because of very sensitive information. Besides, patient anonymity is another most important property, which must be protected. Most recently, Chiou et al. suggested an authentication protocol for TMIS by utilizing the concept of cloud environment. They claimed that their protocol is patient anonymous and well security protected. We reviewed their protocol and found that it is completely insecure against patient anonymity. Further, the same protocol is not protected against mobile device stolen attack. In order to improve security level and complexity, we design a light weight authentication protocol for the same environment. Our security analysis ensures resilience of all possible security attacks. The performance of our protocol is relatively standard in comparison with the related previous research.
EPA Traceability Protocol for Assay and Certification of Gaseous Calibration Standards
In 1997, the U.S. Environmental Protection Agency (EPA) in Research Triangle Park, North Carolina, revised its 1993 version of its traceability protocol for the assay and certification of compressed gas and permeation-device calibration standards. The protocol allows producers o...
Degidi, Marco; Daprile, Giuseppe; Piattelli, Adriano
2015-06-01
The purpose of this present study was to investigate the relation between implant site underpreparation and primary stability in the presence of poor-quality bone. A study was performed on fresh humid bovine bone; samples presented no cortical layer with a cancellous structure inside and were obtained from the hip. The bones were firmly attached to a base device. Sixty sites were prepared according to the protocol provided by the manufacturer: a 2-mm pilot drill was introduced to the proper depth and then twist drills of 3 and 3.4 mm were used. After site preparation, 20 3.4- × 11-mm (standard protocol group), 20 3.8- × 11-mm (10% undersized group), and 20 4.5- × 11-mm (25% undersized group) implants were inserted at a calibrated maximum torque of 70 N-cm at the predetermined speed of 30 rpm. After implant insertion, variable torque work (VTW), maximum insertion torque (peak IT), and resonance frequency analysis (RFA) values were recorded. The standard protocol group showed a mean VTW of 565.77 ± 219.12 N-cm, a peak IT of 11.3 ± 4.44 N-cm, and an RFA of 69.35 ± 7.35 implant stability quotient (ISQ). The 10% undersized group showed a mean VTW of 1,240.24 ± 407.78 N-cm, a peak IT of 20.26 ± 7.03 N-cm, and an RFA of 73.40 ± 2.33 ISQ. The 25% undersized group showed a mean VTW of 1,254.96 ± 727.49 N-cm, a peak IT of 17.15 ± 10.39 N-cm, and an RFA of 72.30 ± 6.70 ISQ. For VTW, the difference between the standard and undersized protocol values was statistically significant; for peak IT, the difference between the standard and 10% undersized protocol values was statistically significant; no other statistical differences were found between mean values. In the presence of poor-bone quality, a 10% undersized protocol is sufficient to improve the primary stability of the implant; additional decreases do not seem to enhance primary stability values. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Chapter A7. Section 7.3. Protozoan Pathogens
Bushon, Rebecca N.; Francy, Donna S.
2003-01-01
Protozoan pathogens are widely distributed in the aquatic environment. Cryptosporidium and Giardia are the principal protozoan pathogens that are known to affect the acceptability of water supplies for public use within the United States. A sampling program for protozoan pathogens should be conducted over an extended period of time because of cyclical and seasonal variations in their concentrations in the environment. This report provides information on the equipment, sampling protocols, and laboratory method that are in standard use by U.S. Geological Survey (USGS) personnel for the collection of data on protozoan pathogens.
Larson, S.J.; Capel, P.D.; VanderLoop, A.G.
1996-01-01
Laboratory and quality assurance procedures for the analysis of ground-water samples for herbicides at the Management Systems Evaluation Area near Princeton, Minnesota are described. The target herbicides include atrazine, de-ethylatrazine, de-isopropylatrazine, metribuzin, alachlor, 2,6-diethylaniline, and metolachlor. The analytical techniques used are solid-phase extraction, and analysis by gas chromatography with mass-selective detection. Descriptions of cleaning procedures, preparation of standard solutions, isolation of analytes from water, sample transfer methods, instrumental analysis, and data analysis are included.
A Novel Approach to Assay DNA Methylation in Prostate Cancer
2016-10-01
prepared into libraries according to standard protocols using Bioo Scientific’s DNA Sample Kit (cat. no. 514101, Austin , TX , USA). Libraries were...Medical Research and Materiel Command Fort Detrick, Maryland 21702-5012 DISTRIBUTION STATEMENT: Approved for Public Release; Distribution Unlimited...ADDRESS(ES) 10. SPONSOR/MONITOR’S ACRONYM(S) U.S. Army Medical Research and Materiel Command Fort Detrick, Maryland 21702-5012 11. SPONSOR/MONITOR’S
Chapter A7. Section 7.2. Fecal Indicator Viruses
Bushon, Rebecca N.
2003-01-01
More than 100 types of human pathogenic viruses may be present in fecal-contaminated waters. Coliphages are used as indicators of virus-related fecal contamination and of the microbiological quality of waters. This report provides information on the equipment, sampling protocols, and laboratory methods that are in standard use by U.S. Geological Survey (USGS) personnel for the collection of data on fecal indicator viruses.
Calcium and Bone Metabolism Indices.
Song, Lu
2017-01-01
Calcium and inorganic phosphate are of critical importance for many body functions, thus the regulations of their plasma concentrations are tightly controlled by the concerted actions of reabsorption/excretion in the kidney, absorption in the intestines, and exchange from bone, the major reservoir for calcium and phosphate in the body. Parathyroid hormone (PTH) and 1,25-dihydroxyvitamin D (1,25(OH) 2 D) control calcium homeostasis, whereas PTH, 1,25(OH) 2 D, and bone-derived fibroblast growth factor 23 (FGF 23) control phosphate homeostasis. Hypoparathyroidism can cause hypocalcemia and hyperphosphatemia, whereas deficient vitamin D actions can cause osteomalacia in adults and rickets in children. Hyperparathyroidism, alternatively, can cause hypercalcemia and hypophosphatemia. Laboratory tests of calcium, phosphate, PTH, and 25-hydroxyvitamin D are very useful in the diagnosis of abnormalities associated with calcium and/or phosphate metabolisms. Bone is constantly remodeled throughout life in response to mechanical stress and a need for calcium in extracellular fluids. Metabolic bone diseases such as osteoporosis, osteomalacia in adults or rickets in children, and renal osteodystrophy develop when bone resorption exceeds bone formation. Bone turnover markers (BTM) such as serum N-terminal propeptide of type I procollagen (P1NP) and C-terminal collagen cross-link (CTX) may be useful in predicting future fracture risk or monitoring the response to anti-resorptive therapy. There is a need to standardize sample collection protocols because certain BTMs exhibit large circadian variations and tend to be influenced by food intakes. In the United States, a project to standardize BTM sample collection protocols and to establish the reference intervals for serum P1NP and serum CTX is ongoing. We anticipate the outcome of this project to shine lights on the standardization of BTM assays, sample collection protocols, reference intervals in relation to age, sex, and ethnic origins, and clinical utilities of BTMs. This review will briefly discuss the regulations of calcium and phosphate homeostasis, laboratory's role in the diagnosis, and monitoring of bone and calcium metabolism, as well as the usefulness and controversies of the utilities of BTMs in the diagnosis and monitoring of metabolic bone diseases. © 2017 Elsevier Inc. All rights reserved.
DOT National Transportation Integrated Search
2004-01-01
This document defines the protocol standards for the Internet Protocol Suite (IPS), which is commonly referred to as Transmission Control Protocol/Internet Protocol (TCP/IP) protocols used for data communications within the National Airspace System (...
In vivo decontamination of the nerve agent VX using the domestic swine model.
Misik, Jan; Pavlik, Michal; Novotny, Ladislav; Pavlikova, Ruzena; Chilcott, Robert P; Cabal, Jiri; Kuca, Kamil
2012-11-01
The purpose of this in vivo study was to assess a new, putatively optimised method for mass casualty decontamination ("ORCHIDS protocol") for effectiveness in removing the chemical warfare agent VX from the skin of anaesthetised, domestic white pigs. ORCHIDS protocol consists of a 1.5-minute shower with a mild detergent (Argos™) supplemented by physical removal. A standard method of wet decontamination was used for comparison. Experimental animals were divided into four groups (A-D). Two groups were exposed to a supra-lethal percutaneous dose (5 × LD(50); 300 μg kg(-1)) of VX for 1 h prior to decontamination with either the ORCHIDS (C) or standard protocol (D). A third (B, positive control) group was exposed but not subject to decontamination. Blank controls (A) received anaesthesia and the corresponding dose of normal saline instead of VX. Observations of the clinical signs of intoxication were supplemented by measurements of whole blood cholinesterase (ChE) performed on samples of arterial blood acquired at 30-minute intervals for the duration of the study (up to 6 h). Untreated (B) animals displayed typical cholinergic signs consistent with VX intoxication (local fasciculation, mastication, salivation, pilo-erection and motor convulsions) and died 165-240 min post exposure. All animals in both decontamination treatment groups (C, D) survived the duration of the study and exhibited less severe signs of cholinergic poisoning. Thus, both the standard and ORCHIDS protocol were demonstrably effective against exposure to the potent nerve agent VX, even after a delay of 1 h. A critical advantage of the ORCHIDS protocol is the relatively short shower duration (1½ min compared to 3 min). In practice, this could substantially improve the rate at which individuals could be decontaminated by emergency responders following exposure to toxic materials such as chemical warfare agents.
Abbreviated Combined MR Protocol: A New Faster Strategy for Characterizing Breast Lesions.
Moschetta, Marco; Telegrafo, Michele; Rella, Leonarda; Stabile Ianora, Amato Antonio; Angelelli, Giuseppe
2016-06-01
The use of an abbreviated magnetic resonance (MR) protocol has been recently proposed for cancer screening. The aim of our study is to evaluate the diagnostic accuracy of an abbreviated MR protocol combining short TI inversion recovery (STIR), turbo-spin-echo (TSE)-T2 sequences, a pre-contrast T1, and a single intermediate (3 minutes after contrast injection) post-contrast T1 sequence for characterizing breast lesions. A total of 470 patients underwent breast MR examination for screening, problem solving, or preoperative staging. Two experienced radiologists evaluated both standard and abbreviated protocols in consensus. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy for both protocols were calculated (with the histological findings and 6-month ultrasound follow-up as the reference standard) and compared with the McNemar test. The post-processing and interpretation times for the MR images were compared with the paired t test. In 177 of 470 (38%) patients, the MR sequences detected 185 breast lesions. Standard and abbreviated protocols obtained sensitivity, specificity, diagnostic accuracy, PPV, and NPV values respectively of 92%, 92%, 92%, 68%, and 98% and of 89%, 91%, 91%, 64%, and 98% with no statistically significant difference (P < .0001). The mean post-processing and interpretation time were, respectively, 7 ± 1 minutes and 6 ± 3.2 minutes for the standard protocol and 1 ± 1.2 minutes and 2 ± 1.2 minutes for the abbreviated protocol, with a statistically significant difference (P < .01). An abbreviated combined MR protocol represents a time-saving tool for radiologists and patients with the same diagnostic potential as the standard protocol in patients undergoing breast MRI for screening, problem solving, or preoperative staging. Copyright © 2016 Elsevier Inc. All rights reserved.
Implementation and Evaluation of Four Interoperable Open Standards for the Internet of Things.
Jazayeri, Mohammad Ali; Liang, Steve H L; Huang, Chih-Yuan
2015-09-22
Recently, researchers are focusing on a new use of the Internet called the Internet of Things (IoT), in which enabled electronic devices can be remotely accessed over the Internet. As the realization of IoT concept is still in its early stages, manufacturers of Internet-connected devices and IoT web service providers are defining their proprietary protocols based on their targeted applications. Consequently, IoT becomes heterogeneous in terms of hardware capabilities and communication protocols. Addressing these heterogeneities by following open standards is a necessary step to communicate with various IoT devices. In this research, we assess the feasibility of applying existing open standards on resource-constrained IoT devices. The standard protocols developed in this research are OGC PUCK over Bluetooth, TinySOS, SOS over CoAP, and OGC SensorThings API. We believe that by hosting open standard protocols on IoT devices, not only do the devices become self-describable, self-contained, and interoperable, but innovative applications can also be easily developed with standardized interfaces. In addition, we use memory consumption, request message size, response message size, and response latency to benchmark the efficiency of the implemented protocols. In all, this research presents and evaluates standard-based solutions to better understand the feasibility of applying existing standards to the IoT vision.
MDP: Reliable File Transfer for Space Missions
NASA Technical Reports Server (NTRS)
Rash, James; Criscuolo, Ed; Hogie, Keith; Parise, Ron; Hennessy, Joseph F. (Technical Monitor)
2002-01-01
This paper presents work being done at NASA/GSFC by the Operating Missions as Nodes on the Internet (OMNI) project to demonstrate the application of the Multicast Dissemination Protocol (MDP) to space missions to reliably transfer files. This work builds on previous work by the OMNI project to apply Internet communication technologies to space communication. The goal of this effort is to provide an inexpensive, reliable, standard, and interoperable mechanism for transferring files in the space communication environment. Limited bandwidth, noise, delay, intermittent connectivity, link asymmetry, and one-way links are all possible issues for space missions. Although these are link-layer issues, they can have a profound effect on the performance of transport and application level protocols. MDP, a UDP-based reliable file transfer protocol, was designed for multicast environments which have to address these same issues, and it has done so successfully. Developed by the Naval Research Lab in the mid 1990's, MDP is now in daily use by both the US Post Office and the DoD. This paper describes the use of MDP to provide automated end-to-end data flow for space missions. It examines the results of a parametric study of MDP in a simulated space link environment and discusses the results in terms of their implications for space missions. Lessons learned are addressed, which suggest minor enhancements to the MDP user interface to add specific features for space mission requirements, such as dynamic control of data rate, and a checkpoint/resume capability. These are features that are provided for in the protocol, but are not implemented in the sample MDP application that was provided. A brief look is also taken at the status of standardization. A version of MDP known as NORM (Neck Oriented Reliable Multicast) is in the process of becoming an IETF standard.
Coron, Noémie; Pihet, Marc; Fréalle, Emilie; Lemeille, Yolande; Pinel, Claudine; Pelloux, Hervé; Gargala, Gilles; Favennec, Loic; Accoceberry, Isabelle; Durand-Joly, Isabelle; Dalle, Frédéric; Huet, Frédéric; Fanton, Annlyse; Boldron, Amale; Loeuille, Guy-André; Domblides, Philippe; Coltey, Bérengère; Pin, Isabelle; Llerena, Catherine; Troussier, Françoise; Person, Christine; Marguet, Christophe; Wizla, Nathalie; Thumerelle, Caroline; Turck, Dominique; Bui, Stéphanie; Fayon, Michael; Duhamel, Alain; Prévotat, Anne; Wallaert, Benoit; Leroy, Sylvie; Bouchara, Jean-Philippe; Delhaes, Laurence
2018-02-01
Fungal respiratory colonization of cystic fibrosis (CF) patients emerges as a new concern; however, the heterogeneity of mycological protocols limits investigations. We first aimed at setting up an efficient standardized protocol for mycological analysis of CF sputa that was assessed during a prospective, multicenter study: "MucoFong" program (PHRC-06/1902). Sputa from 243 CF patients from seven centers in France were collected over a 15-month period and submitted to a standardized protocol based on 6 semi-selective media. After mucolytic pretreatment, sputa were plated in parallel on cycloheximide-enriched (ACT37), erythritol-enriched (ERY37), benomyl dichloran-rose bengal (BENO37) and chromogenic (CAN37) media incubated at 37 °C and on Sabouraud-chloramphenicol (SAB27) and erythritol-enriched (ERY27) media incubated at 20-27 °C. Each plate was checked twice a week during 3 weeks. Fungi were conventionally identified; time for detection of fungal growth was noted for each species. Fungal prevalences and media performances were assessed; an optimal combination of media was determined using the Chi-squared automatic interaction detector method. At least one fungal species was isolated from 81% of sputa. Candida albicans was the most prevalent species (58.8%), followed by Aspergillus fumigatus (35.4%). Cultivation on CAN37, SAB27, ACT37 and ERY27 during 16 days provided an optimal combination, detecting C. albicans, A. fumigatus, Scedosporium apiospermum complex and Exophiala spp. with sensitivities of 96.5, 98.8, 100 and 100%. Combination of these four culture media is recommended to ensure the growth of key fungal pathogens in CF respiratory specimens. The use of such consensual protocol is of major interest for merging results from future epidemiological studies.
Al-Rshaidat, Mamoon M D; Snider, Allison; Rosebraugh, Sydney; Devine, Amanda M; Devine, Thomas D; Plaisance, Laetitia; Knowlton, Nancy; Leray, Matthieu
2016-09-01
High-throughput sequencing (HTS) of DNA barcodes (metabarcoding), particularly when combined with standardized sampling protocols, is one of the most promising approaches for censusing overlooked cryptic invertebrate communities. We present biodiversity estimates based on sequencing of the cytochrome c oxidase subunit 1 (COI) gene for coral reefs of the Gulf of Aqaba, a semi-enclosed system in the northern Red Sea. Samples were obtained from standardized sampling devices (Autonomous Reef Monitoring Structures (ARMS)) deployed for 18 months. DNA barcoding of non-sessile specimens >2 mm revealed 83 OTUs in six phyla, of which only 25% matched a reference sequence in public databases. Metabarcoding of the 2 mm - 500 μm and sessile bulk fractions revealed 1197 OTUs in 15 animal phyla, of which only 4.9% matched reference barcodes. These results highlight the scarcity of COI data for cryptobenthic organisms of the Red Sea. Compared with data obtained using similar methods, our results suggest that Gulf of Aqaba reefs are less diverse than two Pacific coral reefs but much more diverse than an Atlantic oyster reef at a similar latitude. The standardized approaches used here show promise for establishing baseline data on biodiversity, monitoring the impacts of environmental change, and quantifying patterns of diversity at regional and global scales.
Sikulu, Maggy; Govella, Nicodem J; Ogoma, Sheila B; Mpangile, John; Kambi, Said H; Kannady, Khadija; Chaki, Prosper C; Mukabana, Wolfgang R; Killeen, Gerry F
2009-01-01
Background Frequent, sensitive and accurate sampling of Anopheles mosquitoes is a prerequisite for effective management of malaria vector control programmes. The most reliable existing means to measure mosquito density is the human landing catch (HLC). However, the HLC technique raises major ethical concerns because of the necessity to expose humans to vectors of malaria and a variety of other pathogens. Furthermore, it is a very arduous undertaking that requires intense supervision, which is severely limiting in terms of affordability and sustainability. Methods A community-based, mosquito sampling protocol, using the Ifakara tent trap-B (ITT-B) and standardized resting boxes (SRB), was developed and evaluated in terms of the number and sample composition of mosquitoes caught by each, compared to rigorously controlled HLC. Mosquitoes were collected once and three times every week by the HLC and the alternative methods, respectively, in the same time and location. Results Overall, the three traps caught 44,848 mosquitoes. The ITT-B, HLC and SRB caught 168, 143 and 46 Anopheles gambiae s.l. as well as 26,315, 13,258 and 4,791 Culex species respectively. The ITT-B was three- and five-times cheaper than the HLC per mosquito caught for An. gambiae and Cx. Species, respectively. Significant correlations between the numbers caught by HLC and ITT-B were observed for both An. gambiae s.l. (P < 0.001) and Cx. species (P = 0.003). Correlation between the catches with HLC and SRB were observed for Cx. species (P < 0.001) but not An. gambiae s.l. (P = 0.195), presumably because of the low density of the latter. Neither ITT-B nor SRB exhibited any obvious density dependence for sampling the two species. Conclusion SRBs exhibited poor sensitivity for both mosquito taxa and are not recommended in this setting. However, this protocol is affordable and effective for routine use of the ITT-B under programmatic conditions. Nevertheless, it is recommended that the trap and the protocol be evaluated further at full programmatic scales to establish effectiveness under fully representative conditions of routine practice. PMID:19674477
Hoffer, Erica; Tabak, Arek; Shcherb, Inna; Wiener, Avi; Bentur, Yedidia
2005-01-01
A sampling protocol for biomonitoring of the volatile solvent methylene chloride (MeCl(2)) by analysis of urine from exposed workers was established. Storage temperature, sample volume in headspace vial (HSV), and time to sealing HSV on determination of MeCl(2) in urine were evaluated. MeCl(2) was analyzed by a solid-phase microextraction technique combined with gas chromatography. Volume of urine in HSV has no effect on MeCl(2) analysis. Delays of 30 and 60 min from collection of urine until sealing the HSV caused 14.47 +/- 6.98% and 26.17 +/- 9.57% decreases from baseline concentration, respectively. MeCl(2) concentration in spiked urine samples stored in sealed HSVs decreased on day 2 and then remained stable for 2 weeks. Refrigeration did not improve recovery although it seems to be associated with less variability. MeCl(2) in urine samples of seven exposed workers was in the range of 0.02-0.06 mg/L. Sampling of MeCl(2)-containing urine should include collection of urine in closed plastic bottles, transfer to HSV within 15 min, sealing and clamping of HSV within 15 s, and storage of HSV in refrigeration until analysis, but no longer than 2 weeks. Standard samples should be prepared on the day of test sample collection and handled under the same conditions.
de Lecuona, Itziar
2013-01-01
The article explores and analyses the content of the Council of Europe's Additional Protocol to the Convention on Human Rights and Biomedicine concerning Biomedical Research regarding the standard legal instrument in biomedical research, issued by an international organization with leadership in bioethics. This implies ethics committees are mechanisms of protection of humans in biomedical research and not mere bureaucratic agencies and that a sound inescapable international regulatory framework exists for States to regulate biomedical research. The methodology used focuses on the analysis of the background, the context in which it is made and the nature and scope of the Protocol. It also identifies and analyses the characteristics and functions of ethics committees in biomedical research and, in particular, the information that should be provided to this bodies to develop their functions previously, during and at the end of research projects. This analysis will provide guidelines, suggestions and conclusions for the awareness and training of members of these committees in order to influence the daily practice. This paper may also be of interest to legal practitioners who work in different areas of biomedical research. From this practical perspective, the article examines the legal treatment of the Protocol to meet new challenges and classic issues in research: the treatment of human biological samples, the use of placebos, avoiding double standards, human vulnerability, undue influence and conflicts of interest, among others. Also, from a critical view, this work links the legal responses to develop work procedures that are required for an effective performance of the functions assigned of ethics committees in biomedical research. An existing international legal response that lacks doctrinal standards and provides little support should, however, serve as a guide and standard to develop actions that allow ethics committees -as key bodies for States- to advance in the protection of humans in biomedical research.
McNamee, J P; Bellier, P V
2015-07-01
As part of the Japanese Center for the Validation of Alternative Methods (JaCVAM)-initiative international validation study of the in vivo rat alkaline comet assay (comet assay), our laboratory examined ampicillin trihydrate (AMP), 1,2-dimethylhydrazine dihydrochloride (DMH), and N-nitrosodimethylamine (NDA) using a standard comet assay validation protocol (v14.2) developed by the JaCVAM validation management team (VMT). Coded samples were received by our laboratory along with basic MSDS information. Solubility analysis and range-finding experiments of the coded test compounds were conducted for dose selection. Animal dosing schedules, the comet assay processing and analysis, and statistical analysis were conducted in accordance with the standard protocol. Based upon our blinded evaluation, AMP was not found to exhibit evidence of genotoxicity in either the rat liver or stomach. However, both NDA and DMH were observed to cause a significant increase in % tail DNA in the rat liver at all dose levels tested. While acute hepatoxicity was observed for these compounds in the high dose group, in the investigators opinion there were a sufficient number of consistently damaged/measurable cells at the medium and low dose groups to judge these compounds as genotoxic. There was no evidence of genotoxicity from either NDA or DMH in the rat stomach. In conclusion, our laboratory observed increased DNA damage from two blinded test compounds in rat liver (later identified as genotoxic carcinogens), while no evidence of genotoxicity was observed for the third blinded test compound (later identified as a non-genotoxic, non-carcinogen). This data supports the use of a standardized protocol of the in vivo comet assay as a cost-effective alternative genotoxicity assay for regulatory testing purposes. Crown Copyright © 2015. Published by Elsevier B.V. All rights reserved.
Luyckx, K; Dewulf, J; Van Weyenberg, S; Herman, L; Zoons, J; Vervaet, E; Heyndrickx, M; De Reu, K
2015-04-01
Cleaning and disinfection of the broiler stable environment is an essential part of farm hygiene management. Adequate cleaning and disinfection is essential for prevention and control of animal diseases and zoonoses. The goal of this study was to shed light on the dynamics of microbiological and non-microbiological parameters during the successive steps of cleaning and disinfection and to select the most suitable sampling methods and parameters to evaluate cleaning and disinfection in broiler houses. The effectiveness of cleaning and disinfection protocols was measured in six broiler houses on two farms through visual inspection, adenosine triphosphate hygiene monitoring and microbiological analyses. Samples were taken at three time points: 1) before cleaning, 2) after cleaning, and 3) after disinfection. Before cleaning and after disinfection, air samples were taken in addition to agar contact plates and swab samples taken from various sampling points for enumeration of total aerobic flora, Enterococcus spp., and Escherichia coli and the detection of E. coli and Salmonella. After cleaning, air samples, swab samples, and adenosine triphosphate swabs were taken and a visual score was also assigned for each sampling point. The mean total aerobic flora determined by swab samples decreased from 7.7±1.4 to 5.7±1.2 log CFU/625 cm2 after cleaning and to 4.2±1.6 log CFU/625 cm2 after disinfection. Agar contact plates were used as the standard for evaluating cleaning and disinfection, but in this study they were found to be less suitable than swabs for enumeration. In addition to measuring total aerobic flora, Enterococcus spp. seemed to be a better hygiene indicator to evaluate cleaning and disinfection protocols than E. coli. All stables were Salmonella negative, but the detection of its indicator organism E. coli provided additional information for evaluating cleaning and disinfection protocols. Adenosine triphosphate analyses gave additional information about the hygiene level of the different sampling points. © 2015 Poultry Science Association Inc.
In 1997, the U.S. Environmental Protection Agency (EPA) in Research Triangle Park, North Carolina, revised its 1993 version of its traceability protocol for the assay and certification of compressed gas and permeation-device calibration standards. The protocol allows producers of...
Evaluation of a cleanser for petroleum-contaminated skin.
Phieffer, Laura S; Banks, David M; Bosse, Michael J; Meyer, Martha H; Meyer, Ralph A; Smith, Kevin
2003-12-01
Extremity injuries contaminated with petroleum products pose clinical dilemmas. This project was designed to evaluate the efficacy of a dioctyl sulfosuccinate (DS) solution for cleansing petroleum-contaminated skin. One hundred Sprague-Dawley rats were subjected to a contamination protocol followed by a cleansing procedure. Four petroleum contaminants and five cleansing solutions were selected. The protocol consisted of shaving, initial punch biopsy, contamination, precleansing punch biopsy, standardized scrub protocol, and postcleansing punch biopsy. Biopsy samples were analyzed for petroleum residue using fluorometry. The 10% DS solution had the highest reduction of crude oil, grease, and tar: 99.6 +/- 0.4% (mean +/- SD) contaminant reduction for crude oil, 99.8 +/- 0.2% for grease, and 99.8 +/- 0.2% for tar. The other cleansers showed less efficacy (p < 0.05). Concentrated DS appears to be significantly more effective at cleaning petroleum products from skin than the commonly chosen surgical and commercial cleansers.
The Length of Child Anxiety Treatment in a Regional Health System.
Whiteside, Stephen P H; Ale, Chelsea M; Young, Brennan; Olsen, Mark W; Biggs, Bridget K; Gregg, Melissa S; Geske, Jennifer R; Homan, Kendra
2016-12-01
Anxiety disorders are often undertreated due to unsuccessful dissemination of evidence-based treatments (EBTs). Lack of empirical data regarding the typical length of treatment in clinical settings may hamper the development of clinically relevant protocols. The current study examined billing records for 335 children ages 7-17 years to quantify the treatment received for newly diagnosed anxiety disorders within a regional health system. The vast majority of patients did not receive a sufficient number of appointments to complete the typical cognitive behavioral therapy protocol or reach the sessions introducing exposure. Although half of the sample received pharmacotherapy, the vast majority received fewer follow-up appointments than participants in pharmacotherapy research studies. Further, the type of treatment (i.e., number of sessions and medication) differed depending on utilization of specialty care. These results underscore the need to develop brief and flexible EBT protocols that can be standardized and implemented in community practice.
General introduction for the “National Field Manual for the Collection of Water-Quality Data”
,
2018-02-28
BackgroundAs part of its mission, the U.S. Geological Survey (USGS) collects data to assess the quality of our Nation’s water resources. A high degree of reliability and standardization of these data are paramount to fulfilling this mission. Documentation of nationally accepted methods used by USGS personnel serves to maintain consistency and technical quality in data-collection activities. “The National Field Manual for the Collection of Water-Quality Data” (NFM) provides documented guidelines and protocols for USGS field personnel who collect water-quality data. The NFM provides detailed, comprehensive, and citable procedures for monitoring the quality of surface water and groundwater. Topics in the NFM include (1) methods and protocols for sampling water resources, (2) methods for processing samples for analysis of water quality, (3) methods for measuring field parameters, and (4) specialized procedures, such as sampling water for low levels of mercury and organic wastewater chemicals, measuring biological indicators, and sampling bottom sediment for chemistry. Personnel who collect water-quality data for national USGS programs and projects, including projects supported by USGS cooperative programs, are mandated to use protocols provided in the NFM per USGS Office of Water Quality Technical Memorandum 2002.13. Formal training, for example, as provided in the USGS class, “Field Water-Quality Methods for Groundwater and Surface Water,” and field apprenticeships supplement the guidance provided in the NFM and ensure that the data collected are high quality, accurate, and scientifically defensible.
NASA Astrophysics Data System (ADS)
Grulke, Eric A.; Wu, Xiaochun; Ji, Yinglu; Buhr, Egbert; Yamamoto, Kazuhiro; Song, Nam Woong; Stefaniak, Aleksandr B.; Schwegler-Berry, Diane; Burchett, Woodrow W.; Lambert, Joshua; Stromberg, Arnold J.
2018-04-01
Size and shape distributions of gold nanorod samples are critical to their physico-chemical properties, especially their longitudinal surface plasmon resonance. This interlaboratory comparison study developed methods for measuring and evaluating size and shape distributions for gold nanorod samples using transmission electron microscopy (TEM) images. The objective was to determine whether two different samples, which had different performance attributes in their application, were different with respect to their size and/or shape descriptor distributions. Touching particles in the captured images were identified using a ruggedness shape descriptor. Nanorods could be distinguished from nanocubes using an elongational shape descriptor. A non-parametric statistical test showed that cumulative distributions of an elongational shape descriptor, that is, the aspect ratio, were statistically different between the two samples for all laboratories. While the scale parameters of size and shape distributions were similar for both samples, the width parameters of size and shape distributions were statistically different. This protocol fulfills an important need for a standardized approach to measure gold nanorod size and shape distributions for applications in which quantitative measurements and comparisons are important. Furthermore, the validated protocol workflow can be automated, thus providing consistent and rapid measurements of nanorod size and shape distributions for researchers, regulatory agencies, and industry.
González Paredes, Rosa María; García Pinto, Carmelo; Pérez Pavón, José Luis; Moreno Cordero, Bernardo
2016-09-01
A new method based on headspace programmed-temperature vaporizer gas chromatography with mass spectrometry has been developed and validated for the determination of amino acids (alanine, sarcosine, ethylglycine, valine, leucine, and proline) in human urine samples. Derivatization with ethyl chloroformate was employed successfully to determine the amino acids. The derivatization reaction conditions as well as the variables of the headspace sampling were optimized. The existence of a matrix effect was checked and the analytical characteristics of the method were determined. The limits of detection were 0.15-2.89 mg/L, and the limits of quantification were 0.46-8.67 mg/L. The instrumental repeatability was 1.6-11.5%. The quantification of the amino acids in six urine samples from healthy subjects was performed with the method developed with the one-point standard additions protocol, with norleucine as the internal standard. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Santos, E M; Paula, J F R; Motta, P M C; Heinemann, M B; Leite, R C; Haddad, J P A; Del Puerto, H L; Reis, J K P
2010-08-17
We compared three different protocols for DNA extraction from horse peripheral blood mononuclear cells (PBMC) and lung fragments, determining average final DNA concentration, purity, percentage of PCR amplification using beta-actin, and cost. Thirty-four samples from PBMC, and 33 samples from lung fragments were submitted to DNA extraction by three different protocols. Protocol A consisted of a phenol-chloroform and isoamylic alcohol extraction, Protocol B used alkaline extraction with NaOH, and Protocol C used the DNAzol((R)) reagent kit. Protocol A was the best option for DNA extraction from lung fragments, producing high DNA concentrations, with high sensitivity in PCR amplification (100%), followed by Protocols C and B. On the other hand, for PBMC samples, Protocol B gave the highest sensitivity in PCR amplification (100%), followed by Protocols C and A. We conclude that Protocol A should be used for PCR diagnosis from lung fragment samples, while Protocol B should be used for PBMC.
Water-quality sampling by the U.S. Geological Survey-Standard protocols and procedures
Wilde, Franceska D.
2010-01-01
Thumbnail of and link to report PDF (1.0 MB) The U.S. Geological Survey (USGS) develops the sampling procedures and collects the data necessary for the accurate assessment and wise management of our Nation's surface-water and groundwater resources. Federal and State agencies, water-resource regulators and managers, and many organizations and interested parties in the public and private sectors depend on the reliability, timeliness, and integrity of the data we collect and the scientific soundness and impartiality of our data assessments and analysis. The standard data-collection methods uniformly used by USGS water-quality personnel are peer reviewed, kept up-to-date, and published in the National Field Manual for the Collection of Water-Quality Data (http://pubs.water.usgs.gov/twri9A/).
Improving metabolic monitoring in patients maintained on antipsychotics in Penang, Malaysia.
Hor, Esther Sl; Subramaniam, Sivasangari; Koay, Jun Min; Bharathy, Arokiamary; Vasudevan, Umadevi; Panickulam, Joseph J; Ng, InnTiong; Arif, Nor Hayati; Russell, Vincent
2016-02-01
To evaluate the monitoring of metabolic parameters among outpatients maintained on antipsychotic medications in a general hospital setting in Malaysia and to assess the impact of a local monitoring protocol. By performing a baseline audit of files from a random sample of 300 patients prescribed antipsychotic medications for at least 1 year; we determined the frequency of metabolic monitoring. The findings informed the design of a new local protocol, on which clinical staff was briefed. We re-evaluated metabolic monitoring immediately after implementation, in a small sample of new referrals and current patients. We explored staff perceptions of the initiative with a follow-up focus group, 6 months post-implementation. The baseline audit revealed a sub-optimal frequency of metabolic parameter recording. Re-audit, following implementation of the new protocol, revealed improved monitoring but persisting deficits. Dialogue with the clinical staff led to further protocol modification, clearer definition of staff roles and use of a standard recording template. Focus group findings revealed positive perceptions of the initiative, but persisting implementation barriers, including cultural issues surrounding waist circumference measurement. Responding to challenges in achieving improved routine metabolic monitoring of patients maintained on antipsychotics required on-going dialogue with the clinical staff, in order to address both service pressures and cultural concerns. © The Royal Australian and New Zealand College of Psychiatrists 2015.
Host-Associated Metagenomics: A Guide to Generating Infectious RNA Viromes
Robert, Catherine; Pascalis, Hervé; Michelle, Caroline; Jardot, Priscilla; Charrel, Rémi; Raoult, Didier; Desnues, Christelle
2015-01-01
Background Metagenomic analyses have been widely used in the last decade to describe viral communities in various environments or to identify the etiology of human, animal, and plant pathologies. Here, we present a simple and standardized protocol that allows for the purification and sequencing of RNA viromes from complex biological samples with an important reduction of host DNA and RNA contaminants, while preserving the infectivity of viral particles. Principal Findings We evaluated different viral purification steps, random reverse transcriptions and sequence-independent amplifications of a pool of representative RNA viruses. Viruses remained infectious after the purification process. We then validated the protocol by sequencing the RNA virome of human body lice engorged in vitro with artificially contaminated human blood. The full genomes of the most abundant viruses absorbed by the lice during the blood meal were successfully sequenced. Interestingly, random amplifications differed in the genome coverage of segmented RNA viruses. Moreover, the majority of reads were taxonomically identified, and only 7–15% of all reads were classified as “unknown”, depending on the random amplification method. Conclusion The protocol reported here could easily be applied to generate RNA viral metagenomes from complex biological samples of different origins. Our protocol allows further virological characterizations of the described viral communities because it preserves the infectivity of viral particles and allows for the isolation of viruses. PMID:26431175
Probst, Alexander; Facius, Rainer; Wirth, Reinhard; Wolf, Marco; Moissl-Eichinger, Christine
2011-01-01
Microbial contaminants on spacecraft can threaten the scientific integrity of space missions due to probable interference with life detection experiments. Therefore, space agencies measure the cultivable spore load (“bioburden”) of a spacecraft. A recent study has reported an insufficient recovery of Bacillus atrophaeus spores from Vectran fabric, a typical spacecraft airbag material (A. Probst, R. Facius, R. Wirth, and C. Moissl-Eichinger, Appl. Environ. Microbiol. 76:5148-5158, 2010). Here, 10 different sampling methods were compared for B. atrophaeus spore recovery from this rough textile, revealing significantly different efficiencies (0.5 to 15.4%). The most efficient method, based on the wipe-rinse technique (foam-spatula protocol; 13.2% efficiency), was then compared to the current European Space Agency (ESA) standard wipe assay in sampling four different kinds of spacecraft-related surfaces. Results indicate that the novel protocol out-performed the standard method with an average efficiency of 41.1% compared to 13.9% for the standard method. Additional experiments were performed by sampling Vectran fabric seeded with seven different spore concentrations and five different Bacillus species (B. atrophaeus, B. anthracis Sterne, B. megaterium, B. thuringiensis, and B. safensis). Among these, B. atrophaeus spores were recovered with the highest (13.2%) efficiency and B. anthracis Sterne spores were recovered with the lowest (0.3%) efficiency. Different inoculation methods of seeding spores on test surfaces (spotting and aerosolization) resulted in different spore recovery efficiencies. The results of this study provide a step forward in understanding the spore distribution on and recovery from rough surfaces. The results presented will contribute relevant knowledge to the fields of astrobiology and B. anthracis research. PMID:21216908
Lobeck, Inna; Dupree, Phylicia; Karns, Rebekah; Rodeberg, David; von Allmen, Daniel; Dasgupta, Roshni
2017-04-01
Lymph node sampling is integral in the management of extremity and paratesticular rhabdomyosarcoma (RMS). The aim of this study was to determine overall surgical compliance with treatment protocols and impact of nodal sampling outcomes in these tumors. A query of the surveillance, epidemiology, and end results program (SEER) database was performed from 2003 to 2008 for patients <19years of age with RMS. Data obtained included demographics, five-year survival and rate of nodal sampling. Analysis was performed utilizing chi-squared, Kaplan-Meier and hazard ratio modeling. Of 537 patients with extremity RMS, nodal sampling was performed in 25.7% (n=138). This lack of nodal sampling had a negative outcome on survival (p=0.004). Sixty five patients with paratesticular RMS aged greater than 10 were identified and also displayed low rates of lymph node sampling (47.7%, n=31). For paratesticular patients, a similar increase in survival was seen in patients who underwent nodal evaluation (p=0.024). Lymph node sampling is the standard of care in RMS. However, surgical compliance with treatment protocols is poor. Nodal evaluation correlated significantly with overall survival. These findings suggest a need for improved education among surgeons and oncologists regarding the need lymph node assessment in pediatric oncology patients. Evidence rating/classification: Prognosis study, Level III. Copyright © 2017 Elsevier Inc. All rights reserved.
Guidelines and sample protocol for sampling forest gaps.
J.R. Runkle
1992-01-01
A protocol for sampling forest canopy gaps is presented. Methods used in published gap studies are reviewed. The sample protocol will be useful in developing a broader understanding of forest structure and dynamics through comparative studies across different forest ecosystems.
Mena, Marisa; Lloveras, Belen; Tous, Sara; Bogers, Johannes; Maffini, Fausto; Gangane, Nitin; Kumar, Rekha Vijay; Somanathan, Thara; Lucas, Eric; Anantharaman, Devasena; Gheit, Tarik; Castellsagué, Xavier; Pawlita, Michael; de Sanjosé, Silvia; Alemany, Laia; Tommasino, Massimo
2017-01-01
Worldwide use of formalin-fixed paraffin-embedded blocks (FFPE) is extensive in diagnosis and research. Yet, there is a lack of optimized/standardized protocols to process the blocks and verify the quality and presence of the targeted tissue. In the context of an international study on head and neck cancer (HNC)-HPV-AHEAD, a standardized protocol for optimizing the use of FFPEs in molecular epidemiology was developed and validated. First, a protocol for sectioning the FFPE was developed to prevent cross-contamination and distributed between participating centers. Before processing blocks, all sectioning centers underwent a quality control to guarantee a satisfactory training process. The first and last sections of the FFPEs were used for histopathological assessment. A consensus histopathology evaluation form was developed by an international panel of pathologists and evaluated for four indicators in a pilot analysis in order to validate it: 1) presence/type of tumor tissue, 2) identification of other tissue components that could affect the molecular diagnosis and 3) quality of the tissue. No HPV DNA was found in sections from empty FFPE generated in any histology laboratories of HPV-AHEAD consortium and all centers passed quality assurance for processing after quality control. The pilot analysis to validate the histopathology form included 355 HNC cases. The form was filled by six pathologists and each case was randomly assigned to two of them. Most samples (86%) were considered satisfactory. Presence of >50% of invasive carcinoma was observed in all sections of 66% of cases. Substantial necrosis (>50%) was present in <2% of samples. The concordance for the indicators targeted to validate the histopathology form was very high (kappa > 0.85) between first and last sections and fair to high between pathologists (kappa/pabak 0.21-0.72). The protocol allowed to correctly process without signs of contamination all FFPE of the study. The histopathology evaluation of the cases assured the presence of the targeted tissue, identified the presence of other tissues that could disturb the molecular diagnosis and allowed the assessment of tissue quality.
Hill, Dagne D; Owens, William E; Tchounwou, Paul B
2005-04-01
The objective of this research was to compare the chemical/physical parameters and bacterial qualities of selected surface water streams in Louisiana, including a natural stream (control) and an animal waste related stream. Samples were collected and analyzed for fecal coliforms. Fecal coliforms isolated from these samples were identified to the species level. Chemical analysis was performed following standard test protocols (LaMotte 2002). An analysis of biological oxygen demand (BOD), chemical oxygen demand (COD), total organic carbon (TOC), total dissolved solids (TDS), conductivity, pH, temperature, ammonia nitrogen, nitrate nitrogen, iron, copper, phosphate, potassium, sulfate, turbidity, zinc and bacterial levels was performed following standard test protocols as presented in Standard Methods for the Examination of Water and Wastewater [9]. Results of the comparisons of the various surface water streams showed that phosphate levels, according to Mitchell and Stapp, were considered good for Lake Claiborne (control) and Bayou Dorcheat. The levels were found to be .001 mg/L and .007 mg/L respectively. Other streams associated with animal waste, had higher phosphate levels of 2.07 mg/L and 2.78 mg/L, respectively. Conductivity and total dissolved solids (TDS) levels were the lowest in Lake Claiborne and highest in the Hill Farm Research Station stream. It can be concluded from the data that some bacterial levels and various nutrient levels can be affected in water resources due to non-point source pollution. Many of these levels will remain unaffected.
Fussell, Holly E; Kunkel, Lynn E; McCarty, Dennis; Lewy, Colleen S
2011-09-01
Training research staff to implement clinical trials occurring in community-based addiction treatment programs presents unique challenges. Standardized patient walkthroughs of study procedures may enhance training and protocol implementation. Examine and discuss cross-site and cross-study challenges of participant screening and data collection procedures identified during standardized patient walkthroughs of multi-site clinical trials. Actors portrayed clients and "walked through" study procedures with protocol research staff. The study completed 57 walkthroughs during implementation of 4 clinical trials. Observers and walkthrough participants identified three areas of concern (consent procedures, screening and assessment processes, and protocol implementation) and made suggestions for resolving the concerns. Standardized patient walkthroughs capture issues with study procedures previously unidentified with didactic training or unscripted rehearsals. Clinical trials within the National Drug Abuse Treatment Clinical Trials Network are conducted in addiction treatment centers that vary on multiple dimensions. Based on walkthrough observations, the national protocol team and local site leadership modify standardized operating procedures and resolve cross-site problems prior to recruiting study participants. The standardized patient walkthrough improves consistency across study sites and reduces potential site variation in study outcomes.
It's Time to Develop a New "Draft Test Protocol" for a Mars Sample Return Mission (or Two…).
Rummel, John D; Kminek, Gerhard
2018-04-01
The last time NASA envisioned a sample return mission from Mars, the development of a protocol to support the analysis of the samples in a containment facility resulted in a "Draft Test Protocol" that outlined required preparations "for the safe receiving, handling, testing, distributing, and archiving of martian materials here on Earth" (Rummel et al., 2002 ). This document comprised a specific protocol to be used to conduct a biohazard test for a returned martian sample, following the recommendations of the Space Studies Board of the US National Academy of Sciences. Given the planned launch of a sample-collecting and sample-caching rover (Mars 2020) in 2 years' time, and with a sample return planned for the end of the next decade, it is time to revisit the Draft Test Protocol to develop a sample analysis and biohazard test plan to meet the needs of these future missions. Key Words: Biohazard detection-Mars sample analysis-Sample receiving facility-Protocol-New analytical techniques-Robotic sample handling. Astrobiology 18, 377-380.
Chaimani, Anna; Caldwell, Deborah M; Li, Tianjing; Higgins, Julian P T; Salanti, Georgia
2017-03-01
The number of systematic reviews that aim to compare multiple interventions using network meta-analysis is increasing. In this study, we highlight aspects of a standard systematic review protocol that may need modification when multiple interventions are to be compared. We take the protocol format suggested by Cochrane for a standard systematic review as our reference and compare the considerations for a pairwise review with those required for a valid comparison of multiple interventions. We suggest new sections for protocols of systematic reviews including network meta-analyses with a focus on how to evaluate their assumptions. We provide example text from published protocols to exemplify the considerations. Standard systematic review protocols for pairwise meta-analyses need extensions to accommodate the increased complexity of network meta-analysis. Our suggested modifications are widely applicable to both Cochrane and non-Cochrane systematic reviews involving network meta-analyses. Copyright © 2017 Elsevier Inc. All rights reserved.
Vidotto, Laís Silva; Bigliassi, Marcelo; Alencar, Tatiane Romanini Rodrigues; Silva, Thaísa Maria Santos; Probst, Vanessa Suziane
2015-07-01
To compare the acute effects of a standardized physiotherapy protocol versus a typical non-standardized physiotherapy protocol on pain and performance of patients undergoing alveolar bone graft (ABG). Sixteen patients (9 males; 12 [11-13] years) with cleft lip and palate undergoing ABG were allocated into two groups: (1) experimental group--EG (standardized physiotherapy protocol); and (2) control group--CG (typical, non-standardized physiotherapy treatment). Range of motion, muscle strength, gait speed, and pain level were assessed prior to surgical intervention (PRE), as well as on the first, second, and third post-operative days (1st, 2nd, and 3rd PO, respectively). Recovery with respect to range of motion of hip flexion was more pronounced in the EG (64.6 ± 11.0°) in comparison to the CG (48.5 ± 17.7° on the 3rd PO; p < 0.05). In addition, less pain was observed in the EG (0 [0-0.2] versus 2 [0.7-3] in the CG on the 3rd PO; p < 0.05). A standardized physiotherapy protocol appears to be better than a non-standardized physiotherapy protocol for acute improvement of range of motion of hip flexion and for reducing pain in patients undergoing ABG.
Serum Dried Samples to Detect Dengue Antibodies: A Field Study.
Maldonado-Rodríguez, Angelica; Rojas-Montes, Othon; Vazquez-Rosales, Guillermo; Chavez-Negrete, Adolfo; Rojas-Uribe, Magdalena; Posadas-Mondragon, Araceli; Aguilar-Faisal, Leopoldo; Cevallos, Ana Maria; Xoconostle-Cazares, Beatriz; Lira, Rosalia
2017-01-01
Dried blood and serum samples are useful resources for detecting antiviral antibodies. The conditions for elution of the sample need to be optimized for each disease. Dengue is a widespread disease in Mexico which requires continuous surveillance. In this study, we standardized and validated a protocol for the specific detection of dengue antibodies from dried serum spots (DSSs). Paired serum and DSS samples from 66 suspected cases of dengue were collected in a clinic in Veracruz, Mexico. Samples were sent to our laboratory, where the conditions for optimal elution of DSSs were established. The presence of anti-dengue antibodies was determined in the paired samples. DSS elution conditions were standardized as follows: 1 h at 4°C in 200 µ l of DNase-, RNase-, and protease-free PBS (1x). The optimal volume of DSS eluate to be used in the IgG assay was 40 µ l. Sensitivity of 94%, specificity of 93.3%, and kappa concordance of 0.87 were obtained when comparing the antidengue reactivity between DSSs and serum samples. DSS samples are useful for detecting anti-dengue IgG antibodies in the field.
Serum Dried Samples to Detect Dengue Antibodies: A Field Study
Maldonado-Rodríguez, Angelica; Rojas-Montes, Othon; Chavez-Negrete, Adolfo; Rojas-Uribe, Magdalena; Posadas-Mondragon, Araceli; Aguilar-Faisal, Leopoldo; Xoconostle-Cazares, Beatriz
2017-01-01
Background Dried blood and serum samples are useful resources for detecting antiviral antibodies. The conditions for elution of the sample need to be optimized for each disease. Dengue is a widespread disease in Mexico which requires continuous surveillance. In this study, we standardized and validated a protocol for the specific detection of dengue antibodies from dried serum spots (DSSs). Methods Paired serum and DSS samples from 66 suspected cases of dengue were collected in a clinic in Veracruz, Mexico. Samples were sent to our laboratory, where the conditions for optimal elution of DSSs were established. The presence of anti-dengue antibodies was determined in the paired samples. Results DSS elution conditions were standardized as follows: 1 h at 4°C in 200 µl of DNase-, RNase-, and protease-free PBS (1x). The optimal volume of DSS eluate to be used in the IgG assay was 40 µl. Sensitivity of 94%, specificity of 93.3%, and kappa concordance of 0.87 were obtained when comparing the antidengue reactivity between DSSs and serum samples. Conclusion DSS samples are useful for detecting anti-dengue IgG antibodies in the field. PMID:28630868
Batt, Angela L; Furlong, Edward T; Mash, Heath E; Glassmeyer, Susan T; Kolpin, Dana W
2017-02-01
A national-scale survey of 247 contaminants of emerging concern (CECs), including organic and inorganic chemical compounds, and microbial contaminants, was conducted in source and treated drinking water samples from 25 treatment plants across the United States. Multiple methods were used to determine these CECs, including six analytical methods to measure 174 pharmaceuticals, personal care products, and pesticides. A three-component quality assurance/quality control (QA/QC) program was designed for the subset of 174 CECs which allowed us to assess and compare performances of the methods used. The three components included: 1) a common field QA/QC protocol and sample design, 2) individual investigator-developed method-specific QA/QC protocols, and 3) a suite of 46 method comparison analytes that were determined in two or more analytical methods. Overall method performance for the 174 organic chemical CECs was assessed by comparing spiked recoveries in reagent, source, and treated water over a two-year period. In addition to the 247 CECs reported in the larger drinking water study, another 48 pharmaceutical compounds measured did not consistently meet predetermined quality standards. Methodologies that did not seem suitable for these analytes are overviewed. The need to exclude analytes based on method performance demonstrates the importance of additional QA/QC protocols. Published by Elsevier B.V.
An evaluation of direct PCR amplification
Hall, Daniel E.; Roy, Reena
2014-01-01
Aim To generate complete DNA profiles from blood and saliva samples deposited on FTA® and non-FTA® paper substrates following a direct amplification protocol. Methods Saliva samples from living donors and blood samples from deceased individuals were deposited on ten different FTA® and non-FTA® substrates. These ten paper substrates containing body fluids were kept at room temperature for varying lengths of time ranging from one day to approximately one year. For all assays in this research, 1.2 mm punches were collected from each substrate containing one type of body fluid and amplified with reagents provided in the nine commercial polymerase chain reaction (PCR) amplification kits. The substrates were not subjected to purification reagent or extraction buffer prior to amplification. Results Success rates were calculated for all nine amplification kits and all ten substrates based on their ability to yield complete DNA profiles following a direct amplification protocol. Six out of the nine amplification kits, and four out of the ten paper substrates had the highest success rates overall. Conclusion The data show that it is possible to generate complete DNA profiles following a direct amplification protocol using both standard (non-direct) and direct PCR amplification kits. The generation of complete DNA profiles appears to depend more on the success of the amplification kit rather than the than the FTA®- or non-FTA®-based substrates. PMID:25559837
WebTag: Web browsing into sensor tags over NFC.
Echevarria, Juan Jose; Ruiz-de-Garibay, Jonathan; Legarda, Jon; Alvarez, Maite; Ayerbe, Ana; Vazquez, Juan Ignacio
2012-01-01
Information and Communication Technologies (ICTs) continue to overcome many of the challenges related to wireless sensor monitoring, such as for example the design of smarter embedded processors, the improvement of the network architectures, the development of efficient communication protocols or the maximization of the life cycle autonomy. This work tries to improve the communication link of the data transmission in wireless sensor monitoring. The upstream communication link is usually based on standard IP technologies, but the downstream side is always masked with the proprietary protocols used for the wireless link (like ZigBee, Bluetooth, RFID, etc.). This work presents a novel solution (WebTag) for a direct IP based access to a sensor tag over the Near Field Communication (NFC) technology for secure applications. WebTag allows a direct web access to the sensor tag by means of a standard web browser, it reads the sensor data, configures the sampling rate and implements IP based security policies. It is, definitely, a new step towards the evolution of the Internet of Things paradigm.
Optimized protocol for combined PALM-dSTORM imaging.
Glushonkov, O; Réal, E; Boutant, E; Mély, Y; Didier, P
2018-06-08
Multi-colour super-resolution localization microscopy is an efficient technique to study a variety of intracellular processes, including protein-protein interactions. This technique requires specific labels that display transition between fluorescent and non-fluorescent states under given conditions. For the most commonly used label types, photoactivatable fluorescent proteins and organic fluorophores, these conditions are different, making experiments that combine both labels difficult. Here, we demonstrate that changing the standard imaging buffer of thiols/oxygen scavenging system, used for organic fluorophores, to the commercial mounting medium Vectashield increased the number of photons emitted by the fluorescent protein mEos2 and enhanced the photoconversion rate between its green and red forms. In addition, the photophysical properties of organic fluorophores remained unaltered with respect to the standard imaging buffer. The use of Vectashield together with our optimized protocol for correction of sample drift and chromatic aberrations enabled us to perform two-colour 3D super-resolution imaging of the nucleolus and resolve its three compartments.
WebTag: Web Browsing into Sensor Tags over NFC
Echevarria, Juan Jose; Ruiz-de-Garibay, Jonathan; Legarda, Jon; Álvarez, Maite; Ayerbe, Ana; Vazquez, Juan Ignacio
2012-01-01
Information and Communication Technologies (ICTs) continue to overcome many of the challenges related to wireless sensor monitoring, such as for example the design of smarter embedded processors, the improvement of the network architectures, the development of efficient communication protocols or the maximization of the life cycle autonomy. This work tries to improve the communication link of the data transmission in wireless sensor monitoring. The upstream communication link is usually based on standard IP technologies, but the downstream side is always masked with the proprietary protocols used for the wireless link (like ZigBee, Bluetooth, RFID, etc.). This work presents a novel solution (WebTag) for a direct IP based access to a sensor tag over the Near Field Communication (NFC) technology for secure applications. WebTag allows a direct web access to the sensor tag by means of a standard web browser, it reads the sensor data, configures the sampling rate and implements IP based security policies. It is, definitely, a new step towards the evolution of the Internet of Things paradigm. PMID:23012511
Evaluation of Various Cleaning Methods to Remove Bacillus Spores from Spacecraft Hardware Materials
NASA Technical Reports Server (NTRS)
Venkateswaran, Kasthuri; Chung, Shirley; Allton, Judith; Kern, Roger
2004-01-01
A detailed study was made of the biological cleaning effectiveness, defined in terms of the ability to remove bacterial spores, of a number of methods used to clean hardware surfaces. Aluminum (Al 6061) and titanium (Ti 6Al-4V) were chosen for the study as they were deemed the two materials most likely to be used in spacecraft extraterrestrial sampler construction. None of the cleaning protocols tested completely removed viable spores from the surface of the aluminum. In contrast, titanium was capable of being cleaned to sterility by two methods, the JPL standard and the commercial SAMS cleaning process. Further investigation showed that the passivation step employed in the JPL standard method is an effective surface sterilant on both metals but not compatible with aluminum. It is recommended that titanium (Ti 6Al-4V) be considered superior to aluminum (Al 6061) for use in spacecraft sampling hardware, both for its potential to be cleaned to sterilization and for its ability to withstand the most effective cleaning protocols.
Tan, K. E.; Ellis, B. C.; Lee, R.; Stamper, P. D.; Zhang, S. X.
2012-01-01
Matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) has been found to be an accurate, rapid, and inexpensive method for the identification of bacteria and yeasts. Previous evaluations have compared the accuracy, time to identification, and costs of the MALDI-TOF MS method against standard identification systems or commercial panels. In this prospective study, we compared a protocol incorporating MALDI-TOF MS (MALDI protocol) with the current standard identification protocols (standard protocol) to determine the performance in actual practice using a specimen-based, bench-by-bench approach. The potential impact on time to identification (TTI) and costs had MALDI-TOF MS been the first-line identification method was quantitated. The MALDI protocol includes supplementary tests, notably for Streptococcus pneumoniae and Shigella, and indications for repeat MALDI-TOF MS attempts, often not measured in previous studies. A total of 952 isolates (824 bacterial isolates and 128 yeast isolates) recovered from 2,214 specimens were assessed using the MALDI protocol. Compared with standard protocols, the MALDI protocol provided identifications 1.45 days earlier on average (P < 0.001). In our laboratory, we anticipate that the incorporation of the MALDI protocol can reduce reagent and labor costs of identification by $102,424 or 56.9% within 12 months. The model included the fixed annual costs of the MALDI-TOF MS, such as the cost of protein standards and instrument maintenance, and the annual prevalence of organisms encountered in our laboratory. This comprehensive cost analysis model can be generalized to other moderate- to high-volume laboratories. PMID:22855510
Wound-healing outcomes using standardized assessment and care in clinical practice.
Bolton, Laura; McNees, Patrick; van Rijswijk, Lia; de Leon, Jean; Lyder, Courtney; Kobza, Laura; Edman, Kelly; Scheurich, Anne; Shannon, Ron; Toth, Michelle
2004-01-01
Wound-healing outcomes applying standardized protocols have typically been measured within controlled clinical trials, not natural settings. Standardized protocols of wound care have been validated for clinical use, creating an opportunity to measure the resulting outcomes. Wound-healing outcomes were explored during clinical use of standardized validated protocols of care based on patient and wound assessments. This was a prospective multicenter study of wound-healing outcomes management in real-world clinical practice. Healing outcomes from March 26 to October 31, 2001, were recorded on patients in 3 long-term care facilities, 1 long-term acute care hospital, and 12 home care agencies for wounds selected by staff to receive care based on computer-generated validated wound care algorithms. After diagnosis, wound dimensions and status were assessed using a tool adapted from the Pressure Sore Status Toolfor use on all wounds. Wound, ostomy, and continence nursing professionals accessed consistent protocols of care, via telemedicine in home care or paper forms in long-term care. A physician entered assessments into a desktop computer in the wound clinic. Based on evidence that healing proceeds faster with fewer infections in environments without gauze, the protocols generally avoided gauze dressings. Most of the 767 wounds selected to receive the standardized-protocols of care were stage III-IV pressure ulcers (n = 373; mean healing time 62 days) or full-thickness venous ulcers (n = 124; mean healing time 57 days). Partial-thickness wounds healed faster than same-etiology full-thickness wounds. These results provide benchmarks for natural-setting healing outcomes and help to define and address wound care challenges. Outcomes primarily using nongauze protocols of care matched or surpassed best previously published results on similar wounds using gauze-based protocols of care, including protocols applying gauze impregnated with growth factors or other agents.
Tan, K E; Ellis, B C; Lee, R; Stamper, P D; Zhang, S X; Carroll, K C
2012-10-01
Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has been found to be an accurate, rapid, and inexpensive method for the identification of bacteria and yeasts. Previous evaluations have compared the accuracy, time to identification, and costs of the MALDI-TOF MS method against standard identification systems or commercial panels. In this prospective study, we compared a protocol incorporating MALDI-TOF MS (MALDI protocol) with the current standard identification protocols (standard protocol) to determine the performance in actual practice using a specimen-based, bench-by-bench approach. The potential impact on time to identification (TTI) and costs had MALDI-TOF MS been the first-line identification method was quantitated. The MALDI protocol includes supplementary tests, notably for Streptococcus pneumoniae and Shigella, and indications for repeat MALDI-TOF MS attempts, often not measured in previous studies. A total of 952 isolates (824 bacterial isolates and 128 yeast isolates) recovered from 2,214 specimens were assessed using the MALDI protocol. Compared with standard protocols, the MALDI protocol provided identifications 1.45 days earlier on average (P < 0.001). In our laboratory, we anticipate that the incorporation of the MALDI protocol can reduce reagent and labor costs of identification by $102,424 or 56.9% within 12 months. The model included the fixed annual costs of the MALDI-TOF MS, such as the cost of protein standards and instrument maintenance, and the annual prevalence of organisms encountered in our laboratory. This comprehensive cost analysis model can be generalized to other moderate- to high-volume laboratories.
Detection of Salmonella sp in chicken cuts using immunomagnetic separation
de Cássia dos Santos da Conceição, Rita; Moreira, Ângela Nunes; Ramos, Roberta Juliano; Goularte, Fabiana Lemos; Carvalhal, José Beiro; Aleixo, José Antonio Guimarães
2008-01-01
The immunomagnetic separation (IMS) is a technique that has been used to increase sensitivity and specificity and to decrease the time required for detection of Salmonella in foods through different methodologies. In this work we report on the development of a method for detection of Salmonella in chicken cuts using in house antibody-sensitized microspheres associated to conventional plating in selective agar (IMS-plating). First, protein A-coated microspheres were sensitized with polyclonal antibodies against lipopolysacharide and flagella from salmonellae and used to standardize a procedure for capturing Salmonella Enteritidis from pure cultures and detection in selective agar. Subsequently, samples of chicken meat experimentally contaminated with S. Enteritidis were analyzed immediately after contamination and after 24h of refrigeration using three enrichment protocols. The detection limit of the IMS-plating procedure after standardization with pure culture was about 2x10 CFU/mL. The protocol using non-selective enrichment for 6-8h, selective enrichment for 16-18h and a post-enrichment for 4h gave the best results of S. Enteritidis detection by IMS-plating in experimentally contaminated meat. IMS-plating using this protocol was compared to the standard culture method for salmonellae detection in naturally contaminated chicken cuts and yielded 100% sensitivity and 94% specificity. The method developed using in house prepared magnetic microespheres for IMS and plating in selective agar was able to diminish by at least one day the time required for detection of Salmonella in chicken products by the conventional culture method. PMID:24031199
Implementation and Evaluation of Four Interoperable Open Standards for the Internet of Things
Jazayeri, Mohammad Ali; Liang, Steve H. L.; Huang, Chih-Yuan
2015-01-01
Recently, researchers are focusing on a new use of the Internet called the Internet of Things (IoT), in which enabled electronic devices can be remotely accessed over the Internet. As the realization of IoT concept is still in its early stages, manufacturers of Internet-connected devices and IoT web service providers are defining their proprietary protocols based on their targeted applications. Consequently, IoT becomes heterogeneous in terms of hardware capabilities and communication protocols. Addressing these heterogeneities by following open standards is a necessary step to communicate with various IoT devices. In this research, we assess the feasibility of applying existing open standards on resource-constrained IoT devices. The standard protocols developed in this research are OGC PUCK over Bluetooth, TinySOS, SOS over CoAP, and OGC SensorThings API. We believe that by hosting open standard protocols on IoT devices, not only do the devices become self-describable, self-contained, and interoperable, but innovative applications can also be easily developed with standardized interfaces. In addition, we use memory consumption, request message size, response message size, and response latency to benchmark the efficiency of the implemented protocols. In all, this research presents and evaluates standard-based solutions to better understand the feasibility of applying existing standards to the IoT vision. PMID:26402683
Bernard, Lise; Roche, Béatrice; Batisse, Marie; Maqdasy, Salwan; Terral, Daniel; Sautou, Valérie; Tauveron, Igor
2016-10-01
In non-critically ill patients, the use of an insulin syringe pump allows the management of temporary situations during which other therapies cannot be used (failure of subcutaneous injections, awaiting advice from the diabetes team, emergency situations, prolonged corticosteroid therapy, initiation of an artificial nutrition, need for a fasting status, etc.). To manage the risks related to this «never event», the use of a standard validated protocol for insulin administration and monitoring is an essential prerequisite. To this end, a multidisciplinary approach is recommended. With the support of our subcommission «Endocrinology-Diabetology», we proceeded with a «step-by-step process» to create such a standardized protocol: (1) review of all existing protocols in our hospital; (2) overview of the literature data concerning insulin infusion protocols developed by multidisciplinary teams in France and abroad; (3) development of a standardized protocol for non-intensive care unit patients, respecting the current recommendations and adapting it to the working habits of health teams; and (4) validation of the protocol Two protocols based on the same structure but adapted to the health status of the patient have been developed. The protocols are divided in to three parts: (1) golden rules to make the use of the protocol appropriate and safe; (2) the algorithm (a double entry table) corresponding to a dynamic adaptation of insulin doses, clearly defining the target and the 'at risk situations'; and (3) practical aspects of the protocol: preparation of the syringe, treatment initiation and traceability. The protocols have been validated by the institution. Our standardized insulin infusion protocol is simple, easy to implement, safe and is likely to be applicable in diverse care units. However, the efficiency, safety and the workability of our protocols have to be clinically evaluated. © 2016 John Wiley & Sons, Ltd.
Prolonged incubation and stacked film exposure improve sensitivity in western blotting.
Luo, Haitao; Rankin, Gary O; Straley, Shannon; Chen, Yi Charlie
2011-01-01
Western blotting is a basic technique for protein detection. For proteins of less abundance or antibodies of poorer quality, an increased sensitivity is often desired. Although it is commonly known that higher concentrations of antibodies and prolonged film exposure times will help improve sensitivity in western blots, both measures come with their own risks, and it is often unclear to which extent these measures should be applied. We conducted time-course studies to investigate protein-antibody interactions and primary antibody-secondary antibody interactions in western blotting. We also propose a protocol of stacked film exposure and have tested it in standard curves and cancer cell samples. Our study found that protein-primary antibody interactions and primary antibody-secondary antibody interactions could take a longer time than commonly used "one hour" or "overnight", and in some cases longer than 48h, to reach its maximum binding. We also show that the modified protocol of stacked film exposure works well for both standard curves and biological samples, reaching a maximum sensitivity in western blots without blurring target signals or increasing backgrounds. In addition to regular optimization of antibody concentrations and film exposure time, a prolonged incubation with antibodies and stacked film exposure will also help improve sensitivity and reduce background in western blotting. Copyright © 2011 Elsevier Inc. All rights reserved.
Schalch, Barbara; Bader, Lutz; Schau, Hans-Peter; Bergmann, Rolf; Rometsch, Andrea; Maydl, Gertraud; Keßler, Silvia
2003-01-01
In 1998, 21 inhabitants of a German nursing home fell ill with acute gastroenteritis after consumption of minced beef heart (P. Graf and L. Bader, Epidemiol. Bull. 41:327-329, 2000). Two residents died during hospital treatment. Seventeen Clostridium perfringens strains were collected from two different dishes and from patients' stool samples and autopsy materials. A majority of these isolates was not typeable by restriction fragment length polymorphism-pulsed-field gel electrophoresis (PFGE). Subsequent ribotyping of C. perfringens distinguished four different groups. The same ribopattern was detected in a minced beef heart dish, in autopsy material from the two deceased patients, and additionally in stool samples from six further residents who had fallen ill with diarrhea. Three further ribopatterns from food and autopsy materials could be differentiated. As chromosomal macrorestriction with subsequent PFGE is generally regarded more useful than ribotyping for molecular strain analysis, four selected isolates were lysed in parallel with a standard protocol and two nucleases inhibiting modifications. Neither of these methods could differentiate all of the isolates. These results suggest that PFGE with the current standard protocols is not able to characterize all C. perfringens isolates from food-borne disease investigations and that ribotyping is still a helpful method for molecular identification of clonal relationships. PMID:12574310
A contaminant-free assessment of Endogenous Retroviral RNA in human plasma
Karamitros, Timokratis; Paraskevis, Dimitrios; Hatzakis, Angelos; Psichogiou, Mina; Elefsiniotis, Ioannis; Hurst, Tara; Geretti, Anna-Maria; Beloukas, Apostolos; Frater, John; Klenerman, Paul; Katzourakis, Aris; Magiorkinis, Gkikas
2016-01-01
Endogenous retroviruses (ERVs) comprise 6–8% of the human genome. HERVs are silenced in most normal tissues, up-regulated in stem cells and in placenta but also in cancer and HIV-1 infection. Crucially, there are conflicting reports on detecting HERV RNA in non-cellular clinical samples such as plasma that suggest the study of HERV RNA can be daunting. Indeed, we find that the use of real-time PCR in a quality assured clinical laboratory setting can be sensitive to low-level proviral contamination. We developed a mathematical model for low-level contamination that allowed us to design a laboratory protocol and standard operating procedures for robust measurement of HERV RNA. We focus on one family, HERV-K HML-2 (HK2) that has been most recently active even though they invaded our ancestral genomes almost 30 millions ago. We extensively validated our experimental design on a model cell culture system showing high sensitivity and specificity, totally eliminating the proviral contamination. We then tested 236 plasma samples from patients infected with HIV-1, HCV or HBV and found them to be negative. The study of HERV RNA for human translational studies should be performed with extensively validated protocols and standard operating procedures to control the widespread low-level human DNA contamination. PMID:27640347
Satellite Communications Using Commercial Protocols
NASA Technical Reports Server (NTRS)
Ivancic, William D.; Griner, James H.; Dimond, Robert; Frantz, Brian D.; Kachmar, Brian; Shell, Dan
2000-01-01
NASA Glenn Research Center has been working with industry, academia, and other government agencies in assessing commercial communications protocols for satellite and space-based applications. In addition, NASA Glenn has been developing and advocating new satellite-friendly modifications to existing communications protocol standards. This paper summarizes recent research into the applicability of various commercial standard protocols for use over satellite and space- based communications networks as well as expectations for future protocol development. It serves as a reference point from which the detailed work can be readily accessed. Areas that will be addressed include asynchronous-transfer-mode quality of service; completed and ongoing work of the Internet Engineering Task Force; data-link-layer protocol development for unidirectional link routing; and protocols for aeronautical applications, including mobile Internet protocol routing for wireless/mobile hosts and the aeronautical telecommunications network protocol.
Cheikh Ismail, L; Knight, H E; Bhutta, Z; Chumlea, W C
2013-09-01
The primary aim of the INTERGROWTH-21(st) Project is to construct new, prescriptive standards describing optimal fetal and preterm postnatal growth. The anthropometric measurements include the head circumference, recumbent length and weight of the infants, and the stature and weight of the parents. In such a large, international, multicentre project, it is critical that all study sites follow standardised protocols to ensure maximal validity of the growth and nutrition indicators used. This paper describes, in detail, the selection of anthropometric personnel, equipment, and measurement and calibration protocols used to construct the new standards. Implementing these protocols at each study site ensures that the anthropometric data are of the highest quality to construct the international standards. © 2013 Royal College of Obstetricians and Gynaecologists.
Lippert, Dylan; Hoffman, Matthew R; Dang, Phat; McMurray, J Scott; Heatley, Diane; Kille, Tony
2014-12-01
To analyze the safety of a standardized pediatric tracheostomy care protocol in the immediate postoperative period and its impact on tracheostomy related complications. Retrospective case series. Pediatric patients undergoing tracheotomy from February 2010-February 2014. In 2012, a standardized protocol was established regarding postoperative pediatric tracheostomy care. This protocol included securing newly placed tracheostomy tubes using a foam strap with hook and loop fastener rather than twill ties, placing a fresh drain sponge around the tracheostomy tube daily, and performing the first tracheostomy tube change on postoperative day 3 or 4. Outcome measures included rate of skin breakdown and presence of a mature stoma allowing for a safe first tracheostomy tube change. Two types of tracheotomy were performed based on patient age: standard pediatric tracheotomy and adult-style tracheotomy with a Bjork flap. Patients were analyzed separately based on age and the type of tracheotomy performed. Thirty-seven patients in the pre-protocol group and 35 in the post-protocol group were analyzed. The rate of skin breakdown was significantly lower in the post-protocol group (standard: p=0.0048; Bjork flap: p=0.0003). In the post-protocol group, all tube changes were safely accomplished on postoperative day three or four, and the stomas were deemed to be adequately matured to do so in all cases. A standardized postoperative pediatric tracheostomy care protocol resulted in decreased rates of skin breakdown and demonstrated that pediatric tracheostomy tubes can be safely changed as early as 3 days postoperatively. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Influence of lead apron shielding on absorbed doses from panoramic radiography
Rottke, D; Grossekettler, L; Sawada, K; Poxleitner, P; Schulze, D
2013-01-01
Objectives: This study investigated the absorbed doses in a full anthropomorphic body phantom from two different panoramic radiography devices, performing protocols with and without applying a lead apron. Methods: A RANDO® full body phantom (Alderson Research Laboratories Inc., Stamford, CT) was equipped with 110 thermoluminescent dosemeters at 55 different sites and set up in two different panoramic radiography devices [SCANORA® three-dimensional (3D) (SOREDEX, Tuusula, Finland) and ProMax® 3D (Planmeca, Helsinki, Finland)] and exposed. Two different protocols were performed in the two devices. The first protocol was performed without any lead shielding, whereas the phantom was equipped with a standard adult lead apron for the second protocol. Results: A two-tailed paired samples t-test for the SCANORA 3D revealed that there is no difference between the protocol using lead apron shielding (m = 87.99, s = 102.98) and the protocol without shielding (m = 87.34, s = 107.49), t(54) = −0.313, p > 0.05. The same test for the ProMax 3D showed that there is also no difference between the protocol using shielding (m = 106.48, s = 117.38) and the protocol without shielding (m = 107.75, s = 114,36), t(54) = 0.938, p > 0.05. Conclusions: In conclusion, the results of this study showed no statistically significant differences between a panoramic radiography with or without the use of lead apron shielding. PMID:24174012
Influence of lead apron shielding on absorbed doses from panoramic radiography.
Rottke, D; Grossekettler, L; Sawada, K; Poxleitner, P; Schulze, D
2013-01-01
This study investigated the absorbed doses in a full anthropomorphic body phantom from two different panoramic radiography devices, performing protocols with and without applying a lead apron. A RANDO(®) full body phantom (Alderson Research Laboratories Inc., Stamford, CT) was equipped with 110 thermoluminescent dosemeters at 55 different sites and set up in two different panoramic radiography devices [SCANORA(®) three-dimensional (3D) (SOREDEX, Tuusula, Finland) and ProMax(®) 3D (Planmeca, Helsinki, Finland)] and exposed. Two different protocols were performed in the two devices. The first protocol was performed without any lead shielding, whereas the phantom was equipped with a standard adult lead apron for the second protocol. A two-tailed paired samples t-test for the SCANORA 3D revealed that there is no difference between the protocol using lead apron shielding (m = 87.99, s = 102.98) and the protocol without shielding (m = 87.34, s = 107.49), t(54) = -0.313, p > 0.05. The same test for the ProMax 3D showed that there is also no difference between the protocol using shielding (m = 106.48, s = 117.38) and the protocol without shielding (m = 107.75, s = 114,36), t(54) = 0.938, p > 0.05. In conclusion, the results of this study showed no statistically significant differences between a panoramic radiography with or without the use of lead apron shielding.
Influence of lead apron shielding on absorbed doses from panoramic radiography.
Rottke, D; Grossekettler, L; Sawada, K; Poxleitner, P; Schulze, D
2013-01-01
This study investigated the absorbed doses in a full anthropomorphic body phantom from two different panoramic radiography devices, performing protocols with and without applying a lead apron. A RANDO® full body phantom (Alderson Research Laboratories Inc., Stamford, CT) was equipped with 110 thermoluminescent dosemeters at 55 different sites and set up in two different panoramic radiography devices [SCANORA® three-dimensional (3D) (SOREDEX, Tuusula, Finland) and ProMax® 3D (Planmeca, Helsinki, Finland)] and exposed. Two different protocols were performed in the two devices. The first protocol was performed without any lead shielding, whereas the phantom was equipped with a standard adult lead apron for the second protocol. A two-tailed paired samples t-test for the SCANORA 3D revealed that there is no difference between the protocol using lead apron shielding (m = 87.99, s = 102.98) and the protocol without shielding (m = 87.34, s = 107.49), t(54) = −0.313, p > 0.05. The same test for the ProMax 3D showed that there is also no difference between the protocol using shielding (m = 106.48, s = 117.38) and the protocol without shielding (m = 107.75, s = 114,36), t(54) = 0.938, p > 0.05. In conclusion, the results of this study showed no statistically significant differences between a panoramic radiography with or without the use of lead apron shielding.
Dos Santos, Luciana B O; Masini, Jorge C
2007-05-15
This paper describes the development of a sequential injection analysis method to automate the determination of picloram by square wave voltammetry exploiting the concept of monosegmented flow analysis to perform in-line sample conditioning and standard addition. To perform these tasks, an 800muL monosegment is formed, composed by 400muL of sample and 400muL of conditioning/standard solution, in medium of 0.10molL(-1) H(2)SO(4). Homogenization of the monosegment is achieved by three flow reversals. After homogenization the mixture zone is injected toward the flow cell, which is adapted to the capillary of a hanging drop mercury electrode, at a flow rate of 50muLs(-1). After a suitable delay time, the potential is scanned from -0.5 to -1.0V versus Ag/AgCl at frequency of 300Hz and pulse height of 25mV. The linear dynamic range is observed for picloram concentrations between 0.10 and 2.50mgL(-1) fitting to the linear equation I(p)=(-2.19+/-0.03)C(picloram)+(0.096+/-0.039), with R(2)=0.9996, for which the slope is given in muALmg(-1). The detection and quantification limits are 0.036 and 0.12mgL(-1), respectively. The sampling frequency is 37h(-1) when the standard addition protocol is followed, but can be increased to 41h(-1) if the protocol to obtain in-line external calibration curve is used for quantification. The method was applied for determination of picloram in spiked water samples and the accuracy was evaluated by comparison with high performance liquid chromatography using molecular absorption at 220nm for detection. No evidences of statistically significant differences between the two methods were observed.
Medini, Salim; Janin, Myriam; Verdoux, Patrick; Techer, Isabelle
2015-03-15
The lack of a geographical identification protocol for olive oils can lead to fraud and health risks. As some works call for Sr isotopes for the geographical identification of agri-food products, this study focus on the feasibility of extracting Sr from olive oils for isotopic measurements by TIMS. In fact, existing protocols for purification of Sr are unsuitable for lipid matrix. The defined protocol is applied to samples of PDO Nîmes olive oil. The accuracy of the extraction procedure is tested against isotopic standards. The values obtained are in conformity with NIST certified values. This consistency demonstrates that no modification of (87)Sr/(86)Sr ratio is brought about by this protocol. Consequently, the method is preliminary used on PDO Nîmes and Moroccan oils to evaluate the feasibility of a discriminant Sr signature on the two geographical products. This study provides promising results for the geographical discrimination and identification of PDO olive oils. Copyright © 2014 Elsevier Ltd. All rights reserved.
Comparison of test protocols for standard room/corner tests
R. H. White; M. A. Dietenberger; H. Tran; O. Grexa; L. Richardson; K. Sumathipala; M. Janssens
1998-01-01
As part of international efforts to evaluate alternative reaction-to-fire tests, several series of room/comer tests have been conducted. This paper reviews the overall results of related projects in which different test protocols for standard room/corner tests were used. Differences in the test protocols involved two options for the ignition burner scenario and whether...
Development of Standardized Material Testing Protocols for Prosthetic Liners
Cagle, John C.; Reinhall, Per G.; Hafner, Brian J.; Sanders, Joan E.
2017-01-01
A set of protocols was created to characterize prosthetic liners across six clinically relevant material properties. Properties included compressive elasticity, shear elasticity, tensile elasticity, volumetric elasticity, coefficient of friction (CoF), and thermal conductivity. Eighteen prosthetic liners representing the diverse range of commercial products were evaluated to create test procedures that maximized repeatability, minimized error, and provided clinically meaningful results. Shear and tensile elasticity test designs were augmented with finite element analysis (FEA) to optimize specimen geometries. Results showed that because of the wide range of available liner products, the compressive elasticity and tensile elasticity tests required two test maxima; samples were tested until they met either a strain-based or a stress-based maximum, whichever was reached first. The shear and tensile elasticity tests required that no cyclic conditioning be conducted because of limited endurance of the mounting adhesive with some liner materials. The coefficient of friction test was based on dynamic coefficient of friction, as it proved to be a more reliable measurement than static coefficient of friction. The volumetric elasticity test required that air be released beneath samples in the test chamber before testing. The thermal conductivity test best reflected the clinical environment when thermal grease was omitted and when liner samples were placed under pressure consistent with load bearing conditions. The developed procedures provide a standardized approach for evaluating liner products in the prosthetics industry. Test results can be used to improve clinical selection of liners for individual patients and guide development of new liner products. PMID:28233885
Kulstein, Galina; Marienfeld, Ralf; Miltner, Erich; Wiegand, Peter
2016-10-01
In the last years, microRNA (miRNA) analysis came into focus in the field of forensic genetics. Yet, no standardized and recommendable protocols for co-isolation of miRNA and DNA from forensic relevant samples have been developed so far. Hence, this study evaluated the performance of an automated Maxwell® 16 System-based strategy (Promega) for co-extraction of DNA and miRNA from forensically relevant (blood and saliva) samples compared to (semi-)manual extraction methods. Three procedures were compared on the basis of recovered quantity of DNA and miRNA (as determined by real-time PCR and Bioanalyzer), miRNA profiling (shown by Cq values and extraction efficiency), STR profiles, duration, contamination risk and handling. All in all, the results highlight that the automated co-extraction procedure yielded the highest miRNA and DNA amounts from saliva and blood samples compared to both (semi-)manual protocols. Also, for aged and genuine samples of forensically relevant traces the miRNA and DNA yields were sufficient for subsequent downstream analysis. Furthermore, the strategy allows miRNA extraction only in cases where it is relevant to obtain additional information about the sample type. Besides, this system enables flexible sample throughput and labor-saving sample processing with reduced risk of cross-contamination. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Garcia de Leon Valenzuela, Maria Julia
This project explores the reliability of building a biological profile for an unknown individual based on three-dimensional (3D) images of the individual's skeleton. 3D imaging technology has been widely researched for medical and engineering applications, and it is increasingly being used as a tool for anthropological inquiry. While the question of whether a biological profile can be derived from 3D images of a skeleton with the same accuracy as achieved when using dry bones has been explored, bigger sample sizes, a standardized scanning protocol and more interobserver error data are needed before 3D methods can become widely and confidently used in forensic anthropology. 3D images of Computed Tomography (CT) scans were obtained from 130 innominate bones from Boston University's skeletal collection (School of Medicine). For each bone, both 3D images and original bones were assessed using the Phenice and Suchey-Brooks methods. Statistical analysis was used to determine the agreement between 3D image assessment versus traditional assessment. A pool of six individuals with varying experience in the field of forensic anthropology scored a subsample (n = 20) to explore interobserver error. While a high agreement was found for age and sex estimation for specimens scored by the author, the interobserver study shows that observers found it difficult to apply standard methods to 3D images. Higher levels of experience did not result in higher agreement between observers, as would be expected. Thus, a need for training in 3D visualization before applying anthropological methods to 3D bones is suggested. Future research should explore interobserver error using a larger sample size in order to test the hypothesis that training in 3D visualization will result in a higher agreement between scores. The need for the development of a standard scanning protocol focusing on the optimization of 3D image resolution is highlighted. Applications for this research include the possibility of digitizing skeletal collections in order to expand their use and for deriving skeletal collections from living populations and creating population-specific standards. Further research for the development of a standard scanning and processing protocol is needed before 3D methods in forensic anthropology are considered as reliable tools for generating biological profiles.
Mars Sample Handling Protocol Workshop Series: Workshop 4
NASA Technical Reports Server (NTRS)
Race Margaret S. (Editor); DeVincenzi, Donald L. (Editor); Rummel, John D. (Editor); Acevedo, Sara E. (Editor)
2001-01-01
In preparation for missions to Mars that will involve the return of samples to Earth, it will be necessary to prepare for the receiving, handling, testing, distributing, and archiving of martian materials here on Earth. Previous groups and committees have studied selected aspects of sample return activities, but specific detailed protocols for the handling and testing of returned samples must still be developed. To further refine the requirements for sample hazard testing and to develop the criteria for subsequent release of sample materials from quarantine, the NASA Planetary Protection Officer convened a series of workshops in 2000-2001. The overall objective of the Workshop Series was to produce a Draft Protocol by which returned martian sample materials can be assessed for biological hazards and examined for evidence of life (extant or extinct) while safeguarding the purity of the samples from possible terrestrial contamination. This report also provides a record of the proceedings of Workshop 4, the final Workshop of the Series, which was held in Arlington, Virginia, June 5-7, 2001. During Workshop 4, the sub-groups were provided with a draft of the protocol compiled in May 2001 from the work done at prior Workshops in the Series. Then eight sub-groups were formed to discuss the following assigned topics: Review and Assess the Draft Protocol for Physical/Chemical Testing Review and Assess the Draft Protocol for Life Detection Testing Review and Assess the Draft Protocol for Biohazard Testing Environmental and Health/Monitoring and Safety Issues Requirements of the Draft Protocol for Facilities and Equipment Contingency Planning for Different Outcomes of the Draft Protocol Personnel Management Considerations in Implementation of the Draft Protocol Draft Protocol Implementation Process and Update Concepts This report provides the first complete presentation of the Draft Protocol for Mars Sample Handling to meet planetary protection needs. This Draft Protocol, which was compiled from deliberations and recommendations from earlier Workshops in the Series, represents a consensus that emerged from the discussions of all the sub-groups assembled over the course of the five Workshops of the Series. These discussions converged on a conceptual approach to sample handling, as well as on specific analytical requirements. Discussions also identified important issues requiring attention, as well as research and development needed for protocol implementation.
Zou, Lili; Shen, Kaini; Zhong, Dingrong; Zhou, Daobin; Sun, Wei; Li, Jian
2015-01-01
Laser microdissection followed by mass spectrometry has been successfully used for amyloid typing. However, sample contamination can interfere with proteomic analysis, and overnight digestion limits the analytical throughput. Moreover, current quantitative analysis methods are based on the spectrum count, which ignores differences in protein length and may lead to misdiagnoses. Here, we developed a microwave-assisted filter-aided sample preparation (maFASP) method that can efficiently remove contaminants with a 10-kDa cutoff ultrafiltration unit and can accelerate the digestion process with the assistance of a microwave. Additionally, two parameters (P- and D-scores) based on the exponentially modified protein abundance index were developed to define the existence of amyloid deposits and those causative proteins with the greatest abundance. Using our protocol, twenty cases of systemic amyloidosis that were well-typed according to clinical diagnostic standards (training group) and another twenty-four cases without subtype diagnoses (validation group) were analyzed. Using this approach, sample preparation could be completed within four hours. We successfully subtyped 100% of the cases in the training group, and the diagnostic success rate in the validation group was 91.7%. This maFASP-aided proteomic protocol represents an efficient approach for amyloid diagnosis and subtyping, particularly for serum-contaminated samples. PMID:25984759
Influence of Freezing and Storage Procedure on Human Urine Samples in NMR-Based Metabolomics
Rist, Manuela J.; Muhle-Goll, Claudia; Görling, Benjamin; Bub, Achim; Heissler, Stefan; Watzl, Bernhard; Luy, Burkhard
2013-01-01
It is consensus in the metabolomics community that standardized protocols should be followed for sample handling, storage and analysis, as it is of utmost importance to maintain constant measurement conditions to identify subtle biological differences. The aim of this work, therefore, was to systematically investigate the influence of freezing procedures and storage temperatures and their effect on NMR spectra as a potentially disturbing aspect for NMR-based metabolomics studies. Urine samples were collected from two healthy volunteers, centrifuged and divided into aliquots. Urine aliquots were frozen either at −20 °C, on dry ice, at −80 °C or in liquid nitrogen and then stored at −20 °C, −80 °C or in liquid nitrogen vapor phase for 1–5 weeks before NMR analysis. Results show spectral changes depending on the freezing procedure, with samples frozen on dry ice showing the largest deviations. The effect was found to be based on pH differences, which were caused by variations in CO2 concentrations introduced by the freezing procedure. Thus, we recommend that urine samples should be frozen at −20 °C and transferred to lower storage temperatures within one week and that freezing procedures should be part of the publication protocol. PMID:24957990
Influence of Freezing and Storage Procedure on Human Urine Samples in NMR-Based Metabolomics.
Rist, Manuela J; Muhle-Goll, Claudia; Görling, Benjamin; Bub, Achim; Heissler, Stefan; Watzl, Bernhard; Luy, Burkhard
2013-04-09
It is consensus in the metabolomics community that standardized protocols should be followed for sample handling, storage and analysis, as it is of utmost importance to maintain constant measurement conditions to identify subtle biological differences. The aim of this work, therefore, was to systematically investigate the influence of freezing procedures and storage temperatures and their effect on NMR spectra as a potentially disturbing aspect for NMR-based metabolomics studies. Urine samples were collected from two healthy volunteers, centrifuged and divided into aliquots. Urine aliquots were frozen either at -20 °C, on dry ice, at -80 °C or in liquid nitrogen and then stored at -20 °C, -80 °C or in liquid nitrogen vapor phase for 1-5 weeks before NMR analysis. Results show spectral changes depending on the freezing procedure, with samples frozen on dry ice showing the largest deviations. The effect was found to be based on pH differences, which were caused by variations in CO2 concentrations introduced by the freezing procedure. Thus, we recommend that urine samples should be frozen at -20 °C and transferred to lower storage temperatures within one week and that freezing procedures should be part of the publication protocol.
Stephens, John R; Liles, E Allen; Dancel, Ria; Gilchrist, Michael; Kirsch, Jonathan; DeWalt, Darren A
2014-04-01
Clinicians caring for patients seeking alcohol detoxification face many challenges, including lack of evidence-based guidelines for treatment and high recidivism rates. To develop a standardized protocol for determining which alcohol dependent patients seeking detoxification need inpatient versus outpatient treatment, and to study the protocol's implementation. Review of best evidence by ad hoc task force and subsequent creation of standardized protocol. Prospective observational evaluation of initial protocol implementation. Patients presenting for alcohol detoxification. Development and implementation of a protocol for evaluation and treatment of patients requesting alcohol detoxification. Number of admissions per month with primary alcohol related diagnosis (DRG), 30-day readmission rate, and length of stay, all measured before and after protocol implementation. We identified one randomized clinical trial and three cohort studies to inform the choice of inpatient versus outpatient detoxification, along with one prior protocol in this population, and combined that data with clinical experience to create an institutional protocol. After implementation, the average number of alcohol related admissions was 15.9 per month, compared with 18.9 per month before implementation (p = 0.037). There was no difference in readmission rate or length of stay. Creation and utilization of a protocol led to standardization of care for patients requesting detoxification from alcohol. Initial evaluation of protocol implementation showed a decrease in number of admissions.
Loch Vale Watershed Project quality assurance report, 1995-1998
Allstott, E.J.; Bashkin, Michael A.; Baron, Jill S.
1999-01-01
The Loch Vale Watershed (LVWS) project was initiated in 1980 by the National Park Service with funding from the Aquatic Effects Research Program of the National Acid Precipitation Assessment Program. Initial research objectives were to understand the processes that would either mitigate or accelerate the effects of pollution on soil and surface water chemistry, and to build a record in which long-term trends could be identified and examined.It is important for all data collected in Loch Vale to meet the high standards of quality set forth in previous LVWS QA/QC reports and LVWS Methods Manuals. Given the ever-widening usage of data collected in Loch Vale, it is equally important to provide users of that data with a report assuring that all data are sound. Parameters covered in this report are the quality of meteorological measurements, hydrological measurements, surface water chemistry, and similarities in catch efficiency of two raingage types in Loch Vale for the period of 1995-1998.Routine sampling of weather conditions, precipitation chemistry, and stream/lake water chemistry began in 1982. Since then, all samples and data have been analyzed according to widely accepted and published methods. Weather data have been collected, analyzed, and stored by LVWS project personnel. Methods for the handling of meteorological data are well documented (Denning 1988, Edwards 1991, Newkirk 1995,and Allstott 1995). Precipitation chemistry has always been collected according to National Atmospheric Deposition Program protocol (Bigelow 1988), and analyzed at the Central Analytical Laboratory of the Illinois State Water Survey in Champaign, IL. QA/QC procedures of the National Atmospheric Deposition Program are well documented (Aubertin 1990). Protocols for sampling surface waters are also well documented (Newkirk 1995). Analysis of surface water chemistry has been performed using standard EPA protocol at the US Forest Service's Rocky Mt. Station Biogeochemistry Laboratory since 1993.
Psifidi, Androniki; Dovas, Chrysostomos; Banos, Georgios
2011-01-19
Single nucleotide polymorphisms (SNP) have proven to be powerful genetic markers for genetic applications in medicine, life science and agriculture. A variety of methods exist for SNP detection but few can quantify SNP frequencies when the mutated DNA molecules correspond to a small fraction of the wild-type DNA. Furthermore, there is no generally accepted gold standard for SNP quantification, and, in general, currently applied methods give inconsistent results in selected cohorts. In the present study we sought to develop a novel method for accurate detection and quantification of SNP in DNA pooled samples. The development and evaluation of a novel Ligase Chain Reaction (LCR) protocol that uses a DNA-specific fluorescent dye to allow quantitative real-time analysis is described. Different reaction components and thermocycling parameters affecting the efficiency and specificity of LCR were examined. Several protocols, including gap-LCR modifications, were evaluated using plasmid standard and genomic DNA pools. A protocol of choice was identified and applied for the quantification of a polymorphism at codon 136 of the ovine PRNP gene that is associated with susceptibility to a transmissible spongiform encephalopathy in sheep. The real-time LCR protocol developed in the present study showed high sensitivity, accuracy, reproducibility and a wide dynamic range of SNP quantification in different DNA pools. The limits of detection and quantification of SNP frequencies were 0.085% and 0.35%, respectively. The proposed real-time LCR protocol is applicable when sensitive detection and accurate quantification of low copy number mutations in DNA pools is needed. Examples include oncogenes and tumour suppressor genes, infectious diseases, pathogenic bacteria, fungal species, viral mutants, drug resistance resulting from point mutations, and genetically modified organisms in food.
Psifidi, Androniki; Dovas, Chrysostomos; Banos, Georgios
2011-01-01
Background Single nucleotide polymorphisms (SNP) have proven to be powerful genetic markers for genetic applications in medicine, life science and agriculture. A variety of methods exist for SNP detection but few can quantify SNP frequencies when the mutated DNA molecules correspond to a small fraction of the wild-type DNA. Furthermore, there is no generally accepted gold standard for SNP quantification, and, in general, currently applied methods give inconsistent results in selected cohorts. In the present study we sought to develop a novel method for accurate detection and quantification of SNP in DNA pooled samples. Methods The development and evaluation of a novel Ligase Chain Reaction (LCR) protocol that uses a DNA-specific fluorescent dye to allow quantitative real-time analysis is described. Different reaction components and thermocycling parameters affecting the efficiency and specificity of LCR were examined. Several protocols, including gap-LCR modifications, were evaluated using plasmid standard and genomic DNA pools. A protocol of choice was identified and applied for the quantification of a polymorphism at codon 136 of the ovine PRNP gene that is associated with susceptibility to a transmissible spongiform encephalopathy in sheep. Conclusions The real-time LCR protocol developed in the present study showed high sensitivity, accuracy, reproducibility and a wide dynamic range of SNP quantification in different DNA pools. The limits of detection and quantification of SNP frequencies were 0.085% and 0.35%, respectively. Significance The proposed real-time LCR protocol is applicable when sensitive detection and accurate quantification of low copy number mutations in DNA pools is needed. Examples include oncogenes and tumour suppressor genes, infectious diseases, pathogenic bacteria, fungal species, viral mutants, drug resistance resulting from point mutations, and genetically modified organisms in food. PMID:21283808
Evaluation of storage and filtration protocols for alpine/subalpine lake water quality samples
John L. Korfmacher; Robert C. Musselman
2007-01-01
Many government agencies and other organizations sample natural alpine and subalpine surface waters using varying protocols for sample storage and filtration. Simplification of protocols would be beneficial if it could be shown that sample quality is unaffected. In this study, samples collected from low ionic strength waters in alpine and subalpine lake inlets...
Ho, Lisa M; Nelson, Rendon C; Delong, David M
2007-05-01
To prospectively evaluate the use of lean body weight (LBW) as the main determinant of the volume and rate of contrast material administration during multi-detector row computed tomography of the liver. This HIPAA-compliant study had institutional review board approval. All patients gave written informed consent. Four protocols were compared. Standard protocol involved 125 mL of iopamidol injected at 4 mL/sec. Total body weight (TBW) protocol involved 0.7 g iodine per kilogram of TBW. Calculated LBW and measured LBW protocols involved 0.86 g of iodine per kilogram and 0.92 g of iodine per kilogram calculated or measured LBW for men and women, respectively. Injection rate used for the three experimental protocols was determined proportionally on the basis of the calculated volume of contrast material. Postcontrast attenuation measurements during portal venous phase were obtained in liver, portal vein, and aorta for each group and were summed for each patient. Patient-to-patient enhancement variability in same group was measured with Levene test. Two-tailed t test was used to compare the three experimental protocols with the standard protocol. Data analysis was performed in 101 patients (25 or 26 patients per group), including 56 men and 45 women (mean age, 53 years). Average summed attenuation values for standard, TBW, calculated LBW, and measured LBW protocols were 419 HU +/- 50 (standard deviation), 443 HU +/- 51, 433 HU +/- 50, and 426 HU +/- 33, respectively (P = not significant for all). Levene test results for summed attenuation data for standard, TBW, calculated LBW, and measured LBW protocols were 40 +/- 29, 38 +/- 33 (P = .83), 35 +/- 35 (P = .56), and 26 +/- 19 (P = .05), respectively. By excluding highly variable but poorly perfused adipose tissue from calculation of contrast medium dose, the measured LBW protocol may lessen patient-to-patient enhancement variability while maintaining satisfactory hepatic and vascular enhancement.
NASA Astrophysics Data System (ADS)
Martinez, Ralph; Nam, Jiseung
1992-07-01
Picture Archiving and Communication Systems (PACS) is an integration of digital image formation in a hospital, which encompasses various imaging equipment, image viewing workstations, image databases, and a high speed network. The integration requires a standardization of communication protocols to connect devices from different vendors. The American College of Radiology and the National Electrical Manufacturers Association (ACR- NEMA) standard Version 2.0 provides a point-to-point hardware interface, a set of software commands, and a consistent set of data formats for PACS. But, it is inadequate for PACS networking environments, because of its point-to-point nature and its inflexibility to allow other services and protocols in the future. Based on previous experience of PACS developments in The University of Arizona, a new communication protocol for PACS networks and an approach were proposed to ACR-NEMA Working Group VI. The defined PACS protocol is intended to facilitate the development of PACS''s capable of interfacing with other hospital information systems. Also, it is intended to allow the creation of diagnostic information data bases which can be interrogated by a variety of distributed devices. A particularly important goal is to support communications in a multivendor environment. The new protocol specifications are defined primarily as a combination of the International Organization for Standardization/Open Systems Interconnection (ISO/OSI), TCP/IP protocols, and the data format portion of ACR-NEMA standard. This paper addresses the specification and implementation of the ISO-based protocol into a PACS prototype. The protocol specification, which covers Presentation, Session, Transport, and Network layers, is summarized briefly. The protocol implementation is discussed based on our implementation efforts in the UNIX Operating System Environment. At the same time, results of performance comparison between the ISO and TCP/IP implementations are presented to demonstrate the implementation of defined protocol. The testing of performance analysis is done by prototyping PACS on available platforms, which are Micro VAX II, DECstation and SUN Workstation.
7 CFR 301.92-11 - Inspection and sampling protocols.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 5 2010-01-01 2010-01-01 false Inspection and sampling protocols. 301.92-11 Section... Inspection and sampling protocols. Type(s) of plants in the nursery Type(s) of plants shipped interstate... interstate. (1) Annual inspection, sampling, and testing—(i) Inspection. The nursery must be inspected...
7 CFR 301.92-11 - Inspection and sampling protocols.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 5 2011-01-01 2011-01-01 false Inspection and sampling protocols. 301.92-11 Section... Inspection and sampling protocols. Type(s) of plants in the nursery Type(s) of plants shipped interstate... interstate. (1) Annual inspection, sampling, and testing—(i) Inspection. The nursery must be inspected...
Accuracy and precision of Legionella isolation by US laboratories in the ELITE program pilot study.
Lucas, Claressa E; Taylor, Thomas H; Fields, Barry S
2011-10-01
A pilot study for the Environmental Legionella Isolation Techniques Evaluation (ELITE) Program, a proficiency testing scheme for US laboratories that culture Legionella from environmental samples, was conducted September 1, 2008 through March 31, 2009. Participants (n=20) processed panels consisting of six sample types: pure and mixed positive, pure and mixed negative, pure and mixed variable. The majority (93%) of all samples (n=286) were correctly characterized, with 88.5% of samples positive for Legionella and 100% of negative samples identified correctly. Variable samples were incorrectly identified as negative in 36.9% of reports. For all samples reported positive (n=128), participants underestimated the cfu/ml by a mean of 1.25 logs with standard deviation of 0.78 logs, standard error of 0.07 logs, and a range of 3.57 logs compared to the CDC re-test value. Centering results around the interlaboratory mean yielded a standard deviation of 0.65 logs, standard error of 0.06 logs, and a range of 3.22 logs. Sampling protocol, treatment regimen, culture procedure, and laboratory experience did not significantly affect the accuracy or precision of reported concentrations. Qualitative and quantitative results from the ELITE pilot study were similar to reports from a corresponding proficiency testing scheme available in the European Union, indicating these results are probably valid for most environmental laboratories worldwide. The large enumeration error observed suggests that the need for remediation of a water system should not be determined solely by the concentration of Legionella observed in a sample since that value is likely to underestimate the true level of contamination. Published by Elsevier Ltd.
Portu, Agustina; Postuma, Ian; Gadan, Mario Alberto; Saint Martin, Gisela; Olivera, María Silvina; Altieri, Saverio; Protti, Nicoletta; Bortolussi, Silva
2015-11-01
An inter-comparison of three boron determination techniques was carried out between laboratories from INFN-University of Pavia (Italy) and CNEA (Argentina): alpha spectrometry (alpha-spect), neutron capture radiography (NCR) and quantitative autoradiography (QTA). Samples of different nature were analysed: liquid standards, liver homogenates and tissue samples from different treatment protocols. The techniques showed a good agreement in a concentration range of interest in BNCT (1-100ppm), thus demonstrating their applicability as precise methods to quantify boron and determine its distribution in tissues. Copyright © 2015 Elsevier Ltd. All rights reserved.
Phase Transition in Protocols Minimizing Work Fluctuations
NASA Astrophysics Data System (ADS)
Solon, Alexandre P.; Horowitz, Jordan M.
2018-05-01
For two canonical examples of driven mesoscopic systems—a harmonically trapped Brownian particle and a quantum dot—we numerically determine the finite-time protocols that optimize the compromise between the standard deviation and the mean of the dissipated work. In the case of the oscillator, we observe a collection of protocols that smoothly trade off between average work and its fluctuations. However, for the quantum dot, we find that as we shift the weight of our optimization objective from average work to work standard deviation, there is an analog of a first-order phase transition in protocol space: two distinct protocols exchange global optimality with mixed protocols akin to phase coexistence. As a result, the two types of protocols possess qualitatively different properties and remain distinct even in the infinite duration limit: optimal-work-fluctuation protocols never coalesce with the minimal-work protocols, which therefore never become quasistatic.
ASRM standard embryo transfer protocol template: a committee opinion.
Penzias, Alan; Bendikson, Kristin; Butts, Samantha; Coutifaris, Christos; Falcone, Tommaso; Fossum, Gregory; Gitlin, Susan; Gracia, Clarisa; Hansen, Karl; Mersereau, Jennifer; Odem, Randall; Rebar, Robert; Reindollar, Richard; Rosen, Mitchell; Sandlow, Jay; Vernon, Michael
2017-04-01
Standardization improves performance and safety. A template for standardizing the embryo transfer procedure is presented here with 12 basic steps supported by published scientific literature and a survey of common practice of SART programs; it can be used by ART practices to model their own standard protocol. Copyright © 2017 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
ACR/NEMA Digital Image Interface Standard (An Illustrated Protocol Overview)
NASA Astrophysics Data System (ADS)
Lawrence, G. Robert
1985-09-01
The American College of Radiologists (ACR) and the National Electrical Manufacturers Association (NEMA) have sponsored a joint standards committee mandated to develop a universal interface standard for the transfer of radiology images among a variety of PACS imaging devicesl. The resulting standard interface conforms to the ISO/OSI standard reference model for network protocol layering. The standard interface specifies the lower layers of the reference model (Physical, Data Link, Transport and Session) and implies a requirement of the Network Layer should a requirement for a network exist. The message content has been considered and a flexible message and image format specified. The following Imaging Equipment modalities are supported by the standard interface... CT Computed Tomograpy DS Digital Subtraction NM Nuclear Medicine US Ultrasound MR Magnetic Resonance DR Digital Radiology The following data types are standardized over the transmission interface media.... IMAGE DATA DIGITIZED VOICE HEADER DATA RAW DATA TEXT REPORTS GRAPHICS OTHERS This paper consists of text supporting the illustrated protocol data flow. Each layer will be individually treated. Particular emphasis will be given to the Data Link layer (Frames) and the Transport layer (Packets). The discussion utilizes a finite state sequential machine model for the protocol layers.
An XML-Based Protocol for Distributed Event Services
NASA Technical Reports Server (NTRS)
Smith, Warren; Gunter, Dan; Quesnel, Darcy; Biegel, Bryan (Technical Monitor)
2001-01-01
A recent trend in distributed computing is the construction of high-performance distributed systems called computational grids. One difficulty we have encountered is that there is no standard format for the representation of performance information and no standard protocol for transmitting this information. This limits the types of performance analysis that can be undertaken in complex distributed systems. To address this problem, we present an XML-based protocol for transmitting performance events in distributed systems and evaluate the performance of this protocol.
Kish, Mary Z
2014-10-01
The ability of a preterm infant to exclusively oral feed is a necessary standard for discharge readiness from the neonatal intensive care unit (NICU). Many of the interventions related to oral feeding advancement currently employed for preterm infants in the NICU are based on individual nursing observations and judgment. Studies involving standardized feeding protocols for oral feeding advancement have been shown to decrease variability in feeding practices, facilitate shortened transition times from gavage to oral feedings, improve bottle feeding performance, and significantly decrease the length of stay (LOS) in the NICU. This project critically evaluated the implementation of an oral feeding advancement protocol in a 74-bed level III NICU in an attempt to standardize the process of advancing oral feedings in medically stable preterm infants. A comprehensive review of the literature identified key features for successful oral feeding in preterm infants. Strong levels of evidence suggested an association between both nonnutritive sucking (NNS) opportunities and standardized feeding advancement protocols with successful oral feeding in preterm infants. These findings prompted a pilot practice change using a feeding advancement protocol and consisted of NNS and standardized oral feeding advancement opportunities. Time to exclusive oral feedings and LOS were compared pre- and postprotocol implementation during more than a 2-month evaluation period. Infants using NNS and the standardized oral feeding advancement protocol had an observed reduction in time to exclusive oral feedings and LOS, although statistical significance was not achieved.
Rames, Matthew; Yu, Yadong; Ren, Gang
2014-08-15
Structural determination of proteins is rather challenging for proteins with molecular masses between 40 - 200 kDa. Considering that more than half of natural proteins have a molecular mass between 40 - 200 kDa, a robust and high-throughput method with a nanometer resolution capability is needed. Negative staining (NS) electron microscopy (EM) is an easy, rapid, and qualitative approach which has frequently been used in research laboratories to examine protein structure and protein-protein interactions. Unfortunately, conventional NS protocols often generate structural artifacts on proteins, especially with lipoproteins that usually form presenting rouleaux artifacts. By using images of lipoproteins from cryo-electronmore » microscopy (cryo-EM) as a standard, the key parameters in NS specimen preparation conditions were recently screened and reported as the optimized NS protocol (OpNS), a modified conventional NS protocol. Artifacts like rouleaux can be greatly limited by OpNS, additionally providing high contrast along with reasonably high-resolution (near 1 nm) images of small and asymmetric proteins. These high-resolution and high contrast images are even favorable for an individual protein (a single object, no average) 3D reconstruction, such as a 160 kDa antibody, through the method of electron tomography. Moreover, OpNS can be a high-throughput tool to examine hundreds of samples of small proteins. For example, the previously published mechanism of 53 kDa cholesteryl ester transfer protein (CETP) involved the screening and imaging of hundreds of samples. Considering cryo-EM rarely successfully images proteins less than 200 kDa has yet to publish any study involving screening over one hundred sample conditions, it is fair to call OpNS a high-throughput method for studying small proteins. Hopefully the OpNS protocol presented here can be a useful tool to push the boundaries of EM and accelerate EM studies into small protein structure, dynamics and mechanisms.« less
Workshop on standards in biomass for energy and chemicals: proceedings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Milne, T.A.
1984-11-01
In the course of reviewing standards literature, visiting prominent laboratories and research groups, attending biomass meetings and corresponding widely, a whole set of standards needs was identified, the most prominent of which were: biomass standard reference materials, research materials and sample banks; special collections of microorganisms, clonal material, algae, etc.; standard methods of characterization of substrates and biomass fuels; standard tests and methods for the conversion and end-use of biomass; standard protocols for the description, harvesting, preparation, storage, and measurement of productivity of biomass materials in the energy context; glossaries of terms; development of special tests for assay of enzymaticmore » activity and related processes. There was also a recognition of the need for government, professional and industry support of concensus standards development and the dissemination of information on standards. Some 45 biomass researchers and managers met with key NBS staff to identify and prioritize standards needs. This was done through three working panels: the Panel on Standard Reference Materials (SRM's), Research Materials (RM's), and Sample Banks; the Panel on Production and Characterization; and the Panel on Tests and Methods for Conversion and End Use. This report gives a summary of the action items in standards development recommended unanimously by the workshop attendees. The proceedings of the workshop, and an appendix, contain an extensive written record of the findings of the workshop panelists and others regarding presently existing standards and standards issues and needs. Separate abstracts have been prepared for selected papers for inclusion in the Energy Database.« less
Development of a manualized protocol of massage therapy for clinical trials in osteoarthritis.
Ali, Ather; Kahn, Janet; Rosenberger, Lisa; Perlman, Adam I
2012-10-04
Clinical trial design of manual therapies may be especially challenging as techniques are often individualized and practitioner-dependent. This paper describes our methods in creating a standardized Swedish massage protocol tailored to subjects with osteoarthritis of the knee while respectful of the individualized nature of massage therapy, as well as implementation of this protocol in two randomized clinical trials. The manualization process involved a collaborative process between methodologic and clinical experts, with the explicit goals of creating a reproducible semi-structured protocol for massage therapy, while allowing some latitude for therapists' clinical judgment and maintaining consistency with a prior pilot study. The manualized protocol addressed identical specified body regions with distinct 30- and 60-min protocols, using standard Swedish strokes. Each protocol specifies the time allocated to each body region. The manualized 30- and 60-min protocols were implemented in a dual-site 24-week randomized dose-finding trial in patients with osteoarthritis of the knee, and is currently being implemented in a three-site 52-week efficacy trial of manualized Swedish massage therapy. In the dose-finding study, therapists adhered to the protocols and significant treatment effects were demonstrated. The massage protocol was manualized, using standard techniques, and made flexible for individual practitioner and subject needs. The protocol has been applied in two randomized clinical trials. This manualized Swedish massage protocol has real-world utility and can be readily utilized both in the research and clinical settings. Clinicaltrials.gov NCT00970008 (18 August 2009).
A Draft Test Protocol for Detecting Possible Biohazards in Martian Samples Returned to Earth
NASA Technical Reports Server (NTRS)
Rummel, John D. (Editor); Race, Margaret S.; DeVincenzi, Donald L.; Schad, P. Jackson; Stabekis, Pericles D.; Viso, Michel; Acevedo, Sara E.
2002-01-01
This document presents the first complete draft of a protocol for detecting possible biohazards in Mars samples returned to Earth: it is the final product of the Mars Sample Handling Protocol Workshop Series. convened in 2000-2001 by NASA's Planetary Protection Officer. The goal of the five-workshop Series vas to develop a comprehensive protocol by which returned martian sample materials could be assessed k r the presence of any biological hazard(s) while safeguarding the purity of the samples from possible terrestrial contamination.
A Standardized Protocol for the Prospective Follow-Up of Cleft Lip and Palate Patients.
Salimi, Negar; Jolanta, Aleksejūnienė; Edwin, Yen; Angelina, Loo
2018-01-01
To develop a standardized all-encompassing protocol for the assessment of cleft lip and palate patients with clinical and research implications. Electronic database searches were conducted and 13 major cleft centers worldwide were contacted in order to prepare for the development of the protocol. In preparation, the available evidence was reviewed and potential fistula-related risk determinants from 4 different domains were identified. No standardized protocol for the assessment of cleft patients could be found in any of the electronic database searches that were conducted. Interviews with representatives from several major centers revealed that the majority of centers do not have a standardized comprehensive strategy for the reporting and follow-up of cleft lip and palate patients. The protocol was developed and consisted of the following domains of determinants: (1) the sociodemographic domain, (2) the cleft defect domain, (3) the surgery domain, and (4) the fistula domain. The proposed protocol has the potential to enhance the quality of patient care by ensuring that multiple patient-related aspects are consistently reported. It may also facilitate future multicenter research, which could contribute to the reduction of fistula occurrence in cleft lip and palate patients.
Assunção, Cristiane Meira; Goulart, Marcelo; Essvein, Tattiana Enrich; dos Santos, Nicole Marchioro; Erhardt, Maria Carolina Guilherme; Lussi, Adrian; Rodrigues, Jonas de Almeida
2018-01-01
ABSTRACT Objective To evaluate the effect of erosive challenges on the tooth- restoration interface of deciduous teeth treated with different adhesive protocols. Material and Methods Deciduous molars were cut mesiodistally, then embedded, abraded and polished (n=80). Samples were randomly divided according to the adhesive system used into: G1 (Adper Single Bond2®, etch-and-rinse), G2 (Universal Single Bond®, self-etching), G3 (OptibondFL®, etch-and-rinse with Fluoride) and G4 (BondForce®, self-etching with Fluoride). After standardized cavity preparation (2 mm diameter x 2 mm depth), adhesive systems were applied and samples were restored (composite resin Z350®). Half of the samples were exposed to erosive/abrasive cycles (n = 10, each adhesive group), and the other half (control group; n = 10) remained immersed in artificial saliva. For microleakage analysis, samples were submersed in methylene blue and analyzed at 40x magnifications. Cross-sectional microhardness (CSMH) was carried out (50 g/5 s) at 25 μm, 50 μm, and 100 μm from the eroded surface and at 25 μm, 75 μm, and 125 μm from the enamel bond interface. Results Regarding microleakage, 7.5% of the samples showed no dye infiltration, 30% showed dye infiltration only at the enamel interface, and 62.5% showed dye infiltration through the dentin-enamel junction, with no difference between groups (p≥0.05). No significant difference was observed in CSMH at different depths (two-way ANOVA, p≥0.05). Conclusions We did not observe significant changes in microleakage or CSMH after erosive/abrasive challenges in deciduous teeth treated with different adhesive protocols (etch-and-rinse and self-etching adhesives, with and without fluoride). PMID:29364339
Land, Sally; Zhou, Julian; Cunningham, Philip; Sohn, Annette H; Singtoroj, Thida; Katzenstein, David; Mann, Marita; Sayer, David; Kantor, Rami
2013-01-01
Background The TREAT Asia Quality Assessment Scheme (TAQAS) was developed as a quality assessment programme through expert education and training, for laboratories in the Asia-Pacific and Africa that perform HIV drug-resistance (HIVDR) genotyping. We evaluated the programme performance and factors associated with high-quality HIVDR genotyping. Methods Laboratories used their standard protocols to test panels of human immunodeficiency virus (HIV)-positive plasma samples or electropherograms. Protocols were documented and performance was evaluated according to a newly developed scoring system, agreement with panel-specific consensus sequence, and detection of drug-resistance mutations (DRMs) and mixtures of wild-type and resistant virus (mixtures). High-quality performance was defined as detection of ≥95% DRMs. Results Over 4.5 years, 23 participating laboratories in 13 countries tested 45 samples (30 HIV-1 subtype B; 15 non-B subtypes) in nine panels. Median detection of DRMs was 88–98% in plasma panels and 90–97% in electropherogram panels. Laboratories were supported to amend and improve their test outcomes as appropriate. Three laboratories that detected <80% DRMs in early panels demonstrated subsequent improvement. Sample complexity factors – number of DRMs (p<0.001) and number of DRMs as mixtures (p<0.001); and laboratory performance factors – detection of mixtures (p<0.001) and agreement with consensus sequence (p<0.001), were associated with high performance; sample format (plasma or electropherogram), subtype and genotyping protocol were not. Conclusion High-quality HIVDR genotyping was achieved in the TAQAS collaborative laboratory network. Sample complexity and detection of mixtures were associated with performance quality. Laboratories conducting HIVDR genotyping are encouraged to participate in quality assessment programmes. PMID:23845227
Assunção, Cristiane Meira; Goulart, Marcelo; Essvein, Tattiana Enrich; Santos, Nicole Marchioro Dos; Erhardt, Maria Carolina Guilherme; Lussi, Adrian; Rodrigues, Jonas de Almeida
2018-01-18
To evaluate the effect of erosive challenges on the tooth- restoration interface of deciduous teeth treated with different adhesive protocols. Deciduous molars were cut mesiodistally, then embedded, abraded and polished (n=80). Samples were randomly divided according to the adhesive system used into: G1 (Adper Single Bond2®, etch-and-rinse), G2 (Universal Single Bond®, self-etching), G3 (OptibondFL®, etch-and-rinse with Fluoride) and G4 (BondForce®, self-etching with Fluoride). After standardized cavity preparation (2 mm diameter x 2 mm depth), adhesive systems were applied and samples were restored (composite resin Z350®). Half of the samples were exposed to erosive/abrasive cycles (n = 10, each adhesive group), and the other half (control group; n = 10) remained immersed in artificial saliva. For microleakage analysis, samples were submersed in methylene blue and analyzed at 40x magnifications. Cross-sectional microhardness (CSMH) was carried out (50 g/5 s) at 25 μm, 50 μm, and 100 μm from the eroded surface and at 25 μm, 75 μm, and 125 μm from the enamel bond interface. Regarding microleakage, 7.5% of the samples showed no dye infiltration, 30% showed dye infiltration only at the enamel interface, and 62.5% showed dye infiltration through the dentin-enamel junction, with no difference between groups (p≥0.05). No significant difference was observed in CSMH at different depths (two-way ANOVA, p≥0.05). We did not observe significant changes in microleakage or CSMH after erosive/abrasive challenges in deciduous teeth treated with different adhesive protocols (etch-and-rinse and self-etching adhesives, with and without fluoride).
Standardized cell samples for midIR technology development
NASA Astrophysics Data System (ADS)
Kastl, Lena; Rommel, Christina E.; Kemper, Björn; Schnekenburger, Jürgen
2015-03-01
The application of midIR spectroscopy towards human cell and tissue samples is impaired by the need for technical solutions and lacking sample standards for technology development. We here present the standardization of stable test samples for the continuous development and testing of novel optical system components. We have selected cell lines representing the major cellular skin constituents keratinocytes and fibroblasts (NIH-3T3, HaCaT). In addition, two skin cancer cell types (A-375 and SK-MEL-28 cells) were analyzed. Cells were seeded on CaF2 substrates and measured dried and under aqueous medium as well as fixated and unfixated. Several independent cell preparations were analyzed with an FTIR spectrometer in the wave number range from 1000 - 4000 cm-1. The obtained data demonstrate that fixed and dehydrated cells on CaF2 can be stored in pure ethanol for several weeks without significant losses in quality of the spectral properties. The established protocol of cell seeding on CaF2 substrates, chemical fixation, dehydration, storage under ethanol and air-drying is suitable for the production of reliable midIR standards. The retrieved spectra demonstrate that fixed cells on CaF2 can be prepared reproducibly; with stable midIR spectral properties over several weeks and properties mimicking reliable unfixed cells. Moreover, the fixated samples on CaF2 show clear differences in the cell type specific spectra that can be identified by principle component analysis. In summary, the standardized cell culture samples on CaF2 substrates are suitable for the development of a midIR device and the optimization of the specific midIR spectra.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-03
... assess the performance of an approved sampling protocol and to allow for continued sample collection and... developmental sampling protocol. While this application was being reviewed and was available for public comment, the sampling protocol being tested was adopted into the National Shellfish Sanitation Program by the...
Optimizing the high-resolution manometry (HRM) study protocol.
Patel, A; Ding, A; Mirza, F; Gyawali, C P
2015-02-01
Intolerance of the esophageal manometry catheter may prolong high-resolution manometry (HRM) studies and increase patient distress. We assessed the impact of obtaining the landmark phase at the end of the study when the patient has acclimatized to the HRM catheter. 366 patients (mean age 55.4 ± 0.8 years, 62.0% female) undergoing esophageal HRM over a 1-year period were studied. The standard protocol consisted of the landmark phase, 10 5 mL water swallows 20-30 s apart, and multiple rapid swallows where 4-6 2 mL swallows were administered in rapid succession. The modified protocol consisted of the landmark phase at the end of the study after test swallows. Study duration, technical characteristics, indications, and motor findings were compared between standard and modified protocols. Of the 366 patients, 89.6% underwent the standard protocol (study duration 12.9 ± 0.3 min). In 10.4% with poor catheter tolerance undergoing the modified protocol, study duration was significantly longer (15.6 ± 1.0 min, p = 0.004) despite similar duration of study maneuvers. Only elevated upper esophageal sphincter basal pressures at the beginning of the study segregated modified protocol patients. The 95th percentile time to landmark phase in the standard protocol patients was 6.1 min; as many as 31.4% of modified protocol patients could not obtain their first study maneuver within this period (p = 0.0003). Interpretation was not impacted by shifting the landmark phase to the end of the study. Modification of the HRM study protocol with the landmark phase obtained at the end of the study optimizes study duration without compromising quality. © 2014 John Wiley & Sons Ltd.
NASA Technical Reports Server (NTRS)
Hooke, A. J.
1979-01-01
A set of standard telemetry protocols for downlink data flow facilitating the end-to-end transport of instrument data from the spacecraft to the user in real time is proposed. The direct switching of data by autonomous message 'packets' that are assembled by the source instrument on the spacecraft is discussed. The data system consists thus of a format on a message rather than word basis, and such packet telemetry would include standardized protocol headers. Standards are being developed within the NASA End-to-End Data System (NEEDS) program for the source packet and transport frame protocols. The source packet protocol contains identification of both the sequence number of the packet as it is generated by the source and the total length of the packet, while the transport frame protocol includes a sequence count defining the serial number of the frame as it is generated by the spacecraft data system, and a field specifying any 'options' selected in the format of the frame itself.
Dutta, Debargh; Gunasekera, Devi; Ragni, Margaret V; Pratt, Kathleen P
2016-12-27
The most frequent mutations resulting in hemophilia A are an intron 22 or intron 1 gene inversion, which together cause ∼50% of severe hemophilia A cases. We report a simple and accurate RNA-based assay to detect these mutations in patients and heterozygous carriers. The assays do not require specialized equipment or expensive reagents; therefore, they may provide useful and economic protocols that could be standardized for central laboratory testing. RNA is purified from a blood sample, and reverse transcription nested polymerase chain reaction (RT-NPCR) reactions amplify DNA fragments with the F8 sequence spanning the exon 22 to 23 splice site (intron 22 inversion test) or the exon 1 to 2 splice site (intron 1 inversion test). These sequences will be amplified only from F8 RNA without an intron 22 or intron 1 inversion mutation, respectively. Additional RT-NPCR reactions are then carried out to amplify the inverted sequences extending from F8 exon 19 to the first in-frame stop codon within intron 22 or a chimeric transcript containing F8 exon 1 and the VBP1 gene. These latter 2 products are produced only by individuals with an intron 22 or intron 1 inversion mutation, respectively. The intron 22 inversion mutations may be further classified (eg, as type 1 or type 2, reflecting the specific homologous recombination sites) by the standard DNA-based "inverse-shifting" PCR assay if desired. Efficient Bcl I and T4 DNA ligase enzymes that cleave and ligate DNA in minutes were used, which is a substantial improvement over previous protocols that required overnight incubations. These protocols can accurately detect F8 inversion mutations via same-day testing of patient samples.
Tang, Ning; Pahalawatta, Vihanga; Frank, Andrea; Bagley, Zowie; Viana, Raquel; Lampinen, John; Leckie, Gregor; Huang, Shihai; Abravaya, Klara; Wallis, Carole L
2017-07-01
HIV RNA suppression is a key indicator for monitoring success of antiretroviral therapy. From a logistical perspective, viral load (VL) testing using Dried Blood Spots (DBS) is a promising alternative to plasma based VL testing in resource-limited settings. To evaluate the analytical and clinical performance of the Abbott RealTime HIV-1 assay using a fully automated one-spot DBS sample protocol. Limit of detection (LOD), linearity, lower limit of quantitation (LLQ), upper limit of quantitation (ULQ), and precision were determined using serial dilutions of HIV-1 Virology Quality Assurance stock (VQA Rush University), or HIV-1-containing armored RNA, made in venous blood. To evaluate correlation, bias, and agreement, 497 HIV-1 positive adult clinical samples were collected from Ivory Coast, Uganda and South Africa. For each HIV-1 participant, DBS-fingerprick, DBS-venous and plasma sample results were compared. Correlation and bias values were obtained. The sensitivity and specificity were analyzed at a threshold of 1000 HIV-1 copies/mL generated using the standard plasma protocol. The Abbott HIV-1 DBS protocol had an LOD of 839 copies/mL, a linear range from 500 to 1×10 7 copies/mL, an LLQ of 839 copies/mL, a ULQ of 1×10 7 copies/mL, and an inter-assay SD of ≤0.30 log copies/mL for all tested levels within this range. With clinical samples, the correlation coefficient (r value) was 0.896 between DBS-fingerprick and plasma and 0.901 between DBS-venous and plasma, and the bias was -0.07 log copies/mL between DBS-fingerprick and plasma and -0.02 log copies/mL between DBS-venous and plasma. The sensitivity of DBS-fingerprick and DBS-venous was 93%, while the specificity of both DBS methods was 95%. The results demonstrated that the Abbott RealTime HIV-1 assay with DBS sample protocol is highly sensitive, specific and precise across a wide dynamic range and correlates well with plasma values. The Abbott RealTime HIV-1 assay with DBS sample protocol provides an alternative sample collection and transfer option in resource-limited settings and expands the utility of a viral load test to monitor HIV-1 ART treatment for infected patients. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.
Recommended protocols for sampling macrofungi
Gregory M. Mueller; John Paul Schmit; Sabine M. Hubndorf Leif Ryvarden; Thomas E. O' Dell; D. Jean Lodge; Patrick R. Leacock; Milagro Mata; Loengrin Umania; Qiuxin (Florence) Wu; Daniel L. Czederpiltz
2004-01-01
This chapter discusses several issues regarding reommended protocols for sampling macrofungi: Opportunistic sampling of macrofungi, sampling conspicuous macrofungi using fixed-size, sampling small Ascomycetes using microplots, and sampling a fixed number of downed logs.
Prediction of anaerobic power values from an abbreviated WAnT protocol.
Stickley, Christopher D; Hetzler, Ronald K; Kimura, Iris F
2008-05-01
The traditional 30-second Wingate anaerobic test (WAnT) is a widely used anaerobic power assessment protocol. An abbreviated protocol has been shown to decrease the mild to severe physical discomfort often associated with the WAnT. Therefore, the purpose of this study was to determine whether a 20-second WAnT protocol could be used to accurately predict power values of a standard 30-second WAnT. In 96 college females, anaerobic power variables were assessed using a standard 30-second WAnT protocol. Maximum power values as well as instantaneous power at 10, 15, and 20 seconds were recorded. Based on these results, stepwise regression analysis was performed to determine the accuracy with which mean power, minimum power, 30-second power, and percentage of fatigue for a standard 30-second WAnT could be predicted from values obtained during the first 20 seconds of testing. Mean power values showed the highest level of predictability (R2 = 0.99) from the 20-second values. Minimum power, 30-second power, and percentage of fatigue also showed high levels of predictability (R2 = 0.91, 0.84, and 0.84, respectively) using only values obtained during the first 20 seconds of the protocol. An abbreviated (20-second) WAnT protocol appears to effectively predict results of a standard 30-second WAnT in college-age females, allowing for comparison of data to published norms. A shortened test may allow for a decrease in unwanted side effects associated with the traditional WAnT protocol.
SpaceWire Protocol ID: What Does It Mean To You?
NASA Technical Reports Server (NTRS)
Rakow, Glenn; Schnurr, Richard; Gilley, Daniel; Parks, Steve
2006-01-01
Spacewire is becoming a popular solution for satellite high-speed data buses because it is a simple standard that provides great flexibility for a wide range of system requirements. It is simple in packet format and protocol, allowing users to easily tailor their implementation for their specific application. Some of the attractive aspects of Spacewire that make it easy to implement also make it hard for future reuse. Protocol reuse is difficult because Spacewire does not have a defined mechanism to communicate with the higher layers of the protocol stack. This has forced users of Spacewire to define unique packet formats and define how these packets are to be processed. Each mission writes their own Interface Control Document (ICD) and tailors Spacewire for their specific requirements making reuse difficult. Part of the reason for this habit may be because engineers typically optimize designs for their own requirements in the absence of a standard. This is an inefficient use of project resources and costs more to develop missions. A new packet format for Spacewire has been defined as a solution for this problem. This new packet format is a compliment to the Spacewire standard that will support protocol development upon Spacewire. The new packet definition does not replace the current packet structure, i.e., does not make the standard obsolete, but merely extends the standard for those who want to develop protocols over Spacewire. The Spacewire packet is defined with the first part being the Destination Address, which may be one or more bytes. This is followed by the packet cargo, which is user defined. The cargo is truncated with an End-Of-Packet (EOP) marker. This packet structure offers low packet overhead and allows the user to define how the contents are to be formatted. It also provides for many different addressing schemes, which provide flexibility in the system. This packet flexibility is typically an attractive part of the Spacewire. The new extended packet format adds one new field to the packet that greatly enhances the capability of Spacewire. This new field called the Protocol Identifier (ID) is used to identify the packet contents and the associated processing for the packet. This feature along with the restriction in the packet format that uses the Protocol ID, allows a deterministic method of decoding packets that was not before possible. The first part of the packet is still the Destination Address, which still conforms to the original standard but with one restriction. The restriction is that the first byte seen at the destination by the user needs to be a logical address, independent of the addressing scheme used. The second field is defined as the Protocol ID, which is usually one byte in length. The packet cargo (user defined) follows the Protocol ID. After the packet cargo is the EOP, which defines the end of packet. The value of the Protocol ID is assigned by the Spacewire working group and the protocol description published for others to use. The development of Protocols for Spacewire is currently the area of greatest activity by the Spacewire working group. The first protocol definition by the working group has been completed and is now in the process of formal standardization. There are many other protocols in development for missions that have not yet received formal Protocol ID assignment, but even if the protocols are not formally assigned a value, this effort will provide synergism for future developments.
National Sample Assessment Protocols
ERIC Educational Resources Information Center
Ministerial Council on Education, Employment, Training and Youth Affairs (NJ1), 2012
2012-01-01
These protocols represent a working guide for planning and implementing national sample assessments in connection with the national Key Performance Measures (KPMs). The protocols are intended for agencies involved in planning or conducting national sample assessments and personnel responsible for administering associated tenders or contracts,…
Government Open Systems Interconnection Profile (GOSIP) Transition Strategy
1993-09-01
it explores some of the GOSIP protocol details and discusses the process by which standards organizations have developed their...version 1 and 2. Additionally, it explores some of the GOSIP protocol details and discusses the process by which standards organizations have developed ...ORGANIZATION OF STUDY 1. The Standards Process Chapter II describes the process whereby standards are developed and adopted by the ISO and how the
Harding, Keith; Benson, Erica E
2015-01-01
Standard operating procedures are a systematic way of making sure that biopreservation processes, tasks, protocols, and operations are correctly and consistently performed. They are the basic documents of biorepository quality management systems and are used in quality assurance, control, and improvement. Methodologies for constructing workflows and writing standard operating procedures and work instructions are described using a plant cryopreservation protocol as an example. This chapter is pertinent to other biopreservation sectors because how methods are written, interpreted, and implemented can affect the quality of storage outcomes.
[Legionella spp. contamination in indoor air: preliminary results of an Italian multicenter study].
Montagna, Maria Teresa; De Giglio, Osvalda; Napoli, Christian; Cannova, Lucia; Cristina, Maria Luisa; Deriu, Maria Grazia; Delia, Santi Antonino; Giuliano, Ada; Guida, Marco; Laganà, Pasqualina; Liguori, Giorgio; Mura, Ida; Pennino, Francesca; Rossini, Angelo; Tardivo, Stefano; Torre, Ida; Torregrossa, Maria Valeria; Villafrate, Maria Rosaria; Albertini, Roberto; Pasquarella, Cesira
2014-01-01
To propose a standardized protocol for the evaluation of Legionella contamination in air. A bathroom having a Legionella contamination in water >1,000 cfu/l was selected in 10 different healthcare facilities. Air contamination was assessed by active (Surface Air System, SAS) and passive (Index of Microbial Air, IMA) sampling for 8 hours, about 1 m away from the floor and 50 cm from the tap water. Two hundred liters of air were sampled by SAS every 12 min, after flushing water for 2 min. The IMA value was calculated as the mean value of colony forming units/16 plates exposed during sampling (2 plates/hour). Water contamination was evaluated at T0, after 4 and 8 hours, according to the standard methods. Air contamination by Legionella was found in three healthcare facilities (one with active and two with passive sampling), showing a concomitant tap water contamination (median=40,000; range 1,100-43,000 cfu/l). The remaining seven hospitals isolated Legionella spp. exclusively from water samples (median=8,000; range 1,200-70,000 cfu/l). Our data suggest that environmental Legionella contamination cannot be assessed only through the air sampling, even in the presence of an important water contamination.
A new standard of visual data representation for imaging mass spectrometry.
O'Rourke, Matthew B; Padula, Matthew P
2017-03-01
MALDI imaging MS (IMS) is principally used for cancer diagnostics. In our own experience with publishing IMS data, we have been requested to modify our protocols with respect to the areas of the tissue that are imaged in order to comply with the wider literature. In light of this, we have determined that current methodologies lack effective controls and can potentially introduce bias by only imaging specific areas of the targeted tissue EXPERIMENTAL DESIGN: A previously imaged sample was selected and then cropped in different ways to show the potential effect of only imaging targeted areas. By using a model sample, we were able to effectively show how selective imaging of samples can misinterpret tissue features and by changing the areas that are acquired, according to our new standard, an effective internal control can be introduced. Current IMS sampling convention relies on the assumption that sample preparation has been performed correctly. This prevents users from checking whether molecules have moved beyond borders of the tissue due to delocalization and consequentially products of improper sample preparation could be interpreted as biological features that are of critical importance when encountered in a visual diagnostic. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Zhou, Shiyue; Tello, Nadia; Harvey, Alex; Boyes, Barry; Orlando, Ron; Mechref, Yehia
2016-06-01
Glycans have numerous functions in various biological processes and participate in the progress of diseases. Reliable quantitative glycomic profiling techniques could contribute to the understanding of the biological functions of glycans, and lead to the discovery of potential glycan biomarkers for diseases. Although LC-MS is a powerful analytical tool for quantitative glycomics, the variation of ionization efficiency and MS intensity bias are influencing quantitation reliability. Internal standards can be utilized for glycomic quantitation by MS-based methods to reduce variability. In this study, we used stable isotope labeled IgG2b monoclonal antibody, iGlycoMab, as an internal standard to reduce potential for errors and to reduce variabililty due to sample digestion, derivatization, and fluctuation of nanoESI efficiency in the LC-MS analysis of permethylated N-glycans released from model glycoproteins, human blood serum, and breast cancer cell line. We observed an unanticipated degradation of isotope labeled glycans, tracked a source of such degradation, and optimized a sample preparation protocol to minimize degradation of the internal standard glycans. All results indicated the effectiveness of using iGlycoMab to minimize errors originating from sample handling and instruments. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Bijlsma, P B; de Wit, D H; Duindam, J W; Elsinga, G J; Elsinga, W
2013-01-30
This study was aimed to collect data and develop methodologies to determine if and how Dutch biowaste composting plants can meet the microbiological requirements set out in EU-Regulations (EC) 1774/2002 and (EC) 1069/2009, and to provide the European Food and Safety Authority (EFSA) with data and analysis for evaluation of these regulations. We examined twenty plant locations and four types of composting technologies, all with forced aeration and without an anaerobic digestion phase. Raw biowaste, material after sanitation and compost were sampled by spot test analysis according to a standard protocol, and according to an additional protocol with enhanced hygienic precautions. Samples were analyzed for Escherichia coli, Enterococcaceae and Salmonella content. The latter protocol resulted in improved bacterial reductions after sanitation, whereas in compost Enterococcus levels but not E. coli levels increased substantially with both protocols, due to more thermo-resistant regrowth. Salmonella presence in compost coincided with low temperatures and increased levels of E. coli and Enterococcus, absence of Salmonella was associated with absence of E. coli (74%), but not with absence of Enterococcus (17%). In compost, E. coli and Salmonella showed a comparable time-temperature inactivation pattern. A pilot study with co-composting of biowaste and poultry manure indicated a similar inactivation pattern for ESBL-containing bacteria. We conclude that the abundance of Enterococcus in compost is caused by regrowth and not by (re)contamination, and that E. coli is a more reliable indicator species for the absence/presence of Salmonella in compost. Compliance with current EU-regulations concerning biowaste composting can be shown by spot test analysis at all examined plants, provided that adequate hygienic precautions are taken during sampling. Copyright © 2012 Elsevier Ltd. All rights reserved.
Brehmer, Jess L; Husband, Jeffrey B
2014-10-01
There are relatively few studies in the literature that specifically evaluate accelerated rehabilitation protocols for distal radial fractures treated with open reduction and internal fixation (ORIF). The purpose of this study was to compare the early postoperative outcomes (at zero to twelve weeks postoperatively) of patients enrolled in an accelerated rehabilitation protocol with those of patients enrolled in a standard rehabilitation protocol following ORIF for a distal radial fracture. We hypothesized that patients with accelerated rehabilitation after volar ORIF for a distal radial fracture would have an earlier return to function compared with patients who followed a standard protocol. From November 2007 to November 2010, eighty-one patients with an unstable distal radial fracture were prospectively randomized to follow either an accelerated or a standard rehabilitation protocol after undergoing ORIF with a volar plate for a distal radial fracture. Both groups began with gentle active range of motion at three to five days postoperatively. At two weeks, the accelerated group initiated wrist/forearm passive range of motion and strengthening exercises, whereas the standard group initiated passive range of motion and strengthening at six weeks postoperatively. Patients were assessed at three to five days, two weeks, three weeks, four weeks, six weeks, eight weeks, twelve weeks, and six months postoperatively. Outcomes included Disabilities of the Arm, Shoulder and Hand (DASH) scores (primary outcome) and measurements of wrist flexion/extension, supination, pronation, grip strength, and palmar pinch. The patients in the accelerated group had better mobility, strength, and DASH scores at the early postoperative time points (zero to eight weeks postoperatively) compared with the patients in the standard rehabilitation group. The difference between the groups was both clinically relevant and statistically significant. Patients who follow an accelerated rehabilitation protocol that emphasizes motion immediately postoperatively and initiates strengthening at two weeks after volar ORIF of a distal radial fracture have an earlier return to function than patients who follow a more standard rehabilitation protocol. Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.
M.D. Bryant; Trent McDonald; R. Aho; B.E. Wright; Michelle Bourassa Stahl
2008-01-01
We describe a protocol to monitor the effectiveness of the Tongass Land Management Plan (TLMP) management standards for maintaining fish habitat. The protocol uses juvenile coho salmon (Oncorhynchus kisutch) in small tributary streams in forested watersheds. We used a 3-year pilot study to develop detailed methods to estimate juvenile salmonid...
Stergiou, George S; Alpert, Bruce; Mieke, Stephan; Asmar, Roland; Atkins, Neil; Eckert, Siegfried; Frick, Gerhard; Friedman, Bruce; Graßl, Thomas; Ichikawa, Tsutomu; Ioannidis, John P; Lacy, Peter; McManus, Richard; Murray, Alan; Myers, Martin; Palatini, Paolo; Parati, Gianfranco; Quinn, David; Sarkis, Josh; Shennan, Andrew; Usuda, Takashi; Wang, Jiguang; Wu, Colin O; O'Brien, Eoin
2018-03-01
: In the last 30 years, several organizations, such as the US Association for the Advancement of Medical Instrumentation (AAMI), the British Hypertension Society, the European Society of Hypertension (ESH) Working Group on Blood Pressure (BP) Monitoring and the International Organization for Standardization (ISO) have developed protocols for clinical validation of BP measuring devices. However, it is recognized that science, as well as patients, consumers and manufacturers would be best served if all BP measuring devices were assessed for accuracy according to an agreed single validation protocol that had global acceptance. Therefore, an international initiative was taken by AAMI, ESH and ISO experts who agreed to develop a universal standard for device validation. This statement presents the key aspects of a validation procedure, which were agreed by the AAMI, ESH and ISO representatives as the basis for a single universal validation protocol. As soon as the AAMI/ESH/ISO standard is fully developed, this will be regarded as the single universal standard and will replace all other previous standards/protocols.
Stergiou, George S; Alpert, Bruce; Mieke, Stephan; Asmar, Roland; Atkins, Neil; Eckert, Siegfried; Frick, Gerhard; Friedman, Bruce; Graßl, Thomas; Ichikawa, Tsutomu; Ioannidis, John P; Lacy, Peter; McManus, Richard; Murray, Alan; Myers, Martin; Palatini, Paolo; Parati, Gianfranco; Quinn, David; Sarkis, Josh; Shennan, Andrew; Usuda, Takashi; Wang, Jiguang; Wu, Colin O; O'Brien, Eoin
2018-03-01
In the past 30 years, several organizations, such as the US Association for the Advancement of Medical Instrumentation (AAMI), the British Hypertension Society, the European Society of Hypertension (ESH) Working Group on Blood Pressure (BP) Monitoring, and the International Organization for Standardization (ISO), have developed protocols for clinical validation of BP measuring devices. However, it is recognized that science, as well as patients, consumers, and manufacturers, would be best served if all BP measuring devices were assessed for accuracy according to an agreed single validation protocol that had global acceptance. Therefore, an international initiative was taken by the AAMI, ESH, and ISO experts who agreed to develop a universal standard for device validation. This statement presents the key aspects of a validation procedure, which were agreed by the AAMI, ESH, and ISO representatives as the basis for a single universal validation protocol. As soon as the AAMI/ESH/ISO standard is fully developed, this will be regarded as the single universal standard and will replace all other previous standards/protocols. © 2018 American Heart Association, Inc., and Wolters Kluwer Health, Inc.
National Airspace System (NAS) open system architecture and protocols
DOT National Transportation Integrated Search
2003-08-14
This standard establishes the open systems data communications architecture and authorized protocol standards for the National Airspace System (NAS). The NAS will consist of various types of processors and communications networks procured from a vari...
Motion Imagery and Robotics Application (MIRA)
NASA Technical Reports Server (NTRS)
Martinez, Lindolfo; Rich, Thomas
2011-01-01
Objectives include: I. Prototype a camera service leveraging the CCSDS Integrated protocol stack (MIRA/SM&C/AMS/DTN): a) CCSDS MIRA Service (New). b) Spacecraft Monitor and Control (SM&C). c) Asynchronous Messaging Service (AMS). d) Delay/Disruption Tolerant Networking (DTN). II. Additional MIRA Objectives: a) Demo of Camera Control through ISS using CCSDS protocol stack (Berlin, May 2011). b) Verify that the CCSDS standards stack can provide end-to-end space camera services across ground and space environments. c) Test interoperability of various CCSDS protocol standards. d) Identify overlaps in the design and implementations of the CCSDS protocol standards. e) Identify software incompatibilities in the CCSDS stack interfaces. f) Provide redlines to the SM&C, AMS, and DTN working groups. d) Enable the CCSDS MIRA service for potential use in ISS Kibo camera commanding. e) Assist in long-term evolution of this entire group of CCSDS standards to TRL 6 or greater.
Evaluating the Validity Indices of the Personality Assessment Inventory-Adolescent Version.
Meyer, Justin K; Hong, Sang-Hwang; Morey, Leslie C
2015-08-01
Past research has established strong psychometric properties of several indicators of response distortion on the Personality Assessment Inventory (PAI). However, to date, it has been unclear whether the response distortion indicators of the adolescent version of the PAI (PAI-A) operate in an equally valid manner. The current study sought to examine several response distortion indicators on the PAI-A to determine their relative efficacy at the detection of distorted responding, including both positive distortion and negative distortion. Protocols of 98 college students asked to either overreport or underreport were compared with 98 age-matched individuals sampled from the clinical standardization sample and the community standardization sample, respectively. Comparisons between groups were accomplished through the examination of effect sizes and receiver operating characteristic curves. All indicators demonstrated the ability to distinguish between actual and feigned responding, including several newly developed indicators. This study provides support for the ability of distortion indicators developed for the PAI to also function appropriately on the PAI-A. © The Author(s) 2014.
Al-Ekrish, Asma'a A; Al-Shawaf, Reema; Schullian, Peter; Al-Sadhan, Ra'ed; Hörmann, Romed; Widmann, Gerlig
2016-10-01
To assess the comparability of linear measurements of dental implant sites recorded from multidetector computed tomography (MDCT) images obtained using standard-dose filtered backprojection (FBP) technique with those from various ultralow doses combined with FBP, adaptive statistical iterative reconstruction (ASIR), and model-based iterative reconstruction (MBIR) techniques. The results of the study may contribute to MDCT dose optimization for dental implant site imaging. MDCT scans of two cadavers were acquired using a standard reference protocol and four ultralow-dose test protocols (TP). The volume CT dose index of the different dose protocols ranged from a maximum of 30.48-36.71 mGy to a minimum of 0.44-0.53 mGy. All scans were reconstructed using FBP, ASIR-50, ASIR-100, and MBIR, and either a bone or standard reconstruction kernel. Linear measurements were recorded from standardized images of the jaws by two examiners. Intra- and inter-examiner reliability of the measurements were analyzed using Cronbach's alpha and inter-item correlation. Agreement between the measurements obtained with the reference-dose/FBP protocol and each of the test protocols was determined with Bland-Altman plots and linear regression. Statistical significance was set at a P-value of 0.05. No systematic variation was found between the linear measurements obtained with the reference protocol and the other imaging protocols. The only exceptions were TP3/ASIR-50 (bone kernel) and TP4/ASIR-100 (bone and standard kernels). The mean measurement differences between these three protocols and the reference protocol were within ±0.1 mm, with the 95 % confidence interval limits being within the range of ±1.15 mm. A nearly 97.5 % reduction in dose did not significantly affect the height and width measurements of edentulous jaws regardless of the reconstruction algorithm used.
A Draft Test Protocol for Detecting Possible Biohazards in Martian Samples Returned to Earth
NASA Technical Reports Server (NTRS)
Rummel, John D.; Race, Margaret S.; DeVinenzi, Donald L.; Schad, P. Jackson; Stabekis, Pericles D.; Viso, Michel; Acevedo, Sara E.
2002-01-01
This document presents the first complete draft of a protocol for detecting possible biohazards in Mars samples returned to Earth; it is the final product of the Mars Sample Handling Protocol Workshop Series, convened in 2000-2001 by NASA's Planetary Protection Officer. The goal of the five-workshop Series vas to develop a comprehensive protocol by which returned martian sample materials could be assessed for the presence of any biological hazard(s) while safeguarding the purity of the samples from possible terrestrial contamination The reference numbers for the proceedings from the five individual Workshops.
The New York Brain Bank of Columbia University: practical highlights of 35 years of experience.
Ramirez, Etty Paola Cortes; Keller, Christian Ernst; Vonsattel, Jean Paul
2018-01-01
The New York Brain Bank processes brains and organs of clinically well-characterized patients with age-related neurodegenerative diseases, and for comparison, from individuals without neurologic or psychiatric impairments. The donors, either patients or individuals, were evaluated at healthcare facilities of the Columbia University of New York. Each source brain yields four categories of samples: fresh frozen blocks and crushed parenchyma, and formalin-fixed wet blocks and histology sections. A source brain is thoroughly evaluated to determine qualitatively and quantitatively any changes it might harbor using conventional neuropathologic techniques. The clinical and pathologic diagnoses are integrated to determine the distributive diagnosis assigned to the samples obtained from a source brain. The gradual standardization of the protocol was developed in 1981 in response to the evolving requirements of basic investigations on neurodegeneration. The methods assimilate long-standing experience from multiple centers. The resulting and current protocol includes a constant central core applied to all brains with conditional flexibility around it. The New York Brain Bank is an integral part of the department of pathology, where the expertise, teaching duties, and hardware are shared. Since details of the protocols are available online, this chapter focuses on practical issues in professionalizing brain banking. Copyright © 2018 Elsevier B.V. All rights reserved.
Electron microscopy using the genetically encoded APEX2 tag in cultured mammalian cells
Martell, Jeffrey D; Deerinck, Thomas J; Lam, Stephanie S; Ellisman, Mark H; Ting, Alice Y
2018-01-01
Electron microscopy (EM) is the premiere technique for high-resolution imaging of cellular ultrastructure. Unambiguous identification of specific proteins or cellular compartments in electron micrographs, however, remains challenging because of difficulties in delivering electron-dense contrast agents to specific subcellular targets within intact cells. We recently reported enhanced ascorbate peroxidase 2 (APEX2) as a broadly applicable genetic tag that generates EM contrast on a specific protein or subcellular compartment of interest. This protocol provides guidelines for designing and validating APEX2 fusion constructs, along with detailed instructions for cell culture, transfection, fixation, heavy-metal staining, embedding in resin, and EM imaging. Although this protocol focuses on EM in cultured mammalian cells, APEX2 is applicable to many cell types and contexts, including intact tissues and organisms, and is useful for numerous applications beyond EM, including live-cell proteomic mapping. This protocol, which describes procedures for sample preparation from cell monolayers and cell pellets, can be completed in 10 d, including time for APEX2 fusion construct validation, cell growth, and solidification of embedding resins. Notably, the only additional steps required relative to a standard EM sample preparation are cell transfection and a 2- to 45-min staining period with 3,3′-diaminobenzidine (DAB) and hydrogen peroxide (H2O2). PMID:28796234
The importance of quality control in validating concentrations ...
A national-scale survey of 247 contaminants of emerging concern (CECs), including organic and inorganic chemical compounds, and microbial contaminants, was conducted in source and treated drinking water samples from 25 treatment plants across the United States. Multiple methods were used to determine these CECs, including six analytical methods to measure 174 pharmaceuticals, personal care products, and pesticides. A three-component quality assurance/quality control (QA/QC) program was designed for the subset of 174 CECs which allowed us to assess and compare performances of the methods used. The three components included: 1) a common field QA/QC protocol and sample design, 2) individual investigator-developed method-specific QA/QC protocols, and 3) a suite of 46 method comparison analytes that were determined in two or more analytical methods. Overall method performance for the 174 organic chemical CECs was assessed by comparing spiked recoveries in reagent, source, and treated water over a two-year period. In addition to the 247 CECs reported in the larger drinking water study, another 48 pharmaceutical compounds measured did not consistently meet predetermined quality standards. Methodologies that did not seem suitable for these analytes are overviewed. The need to exclude analytes based on method performance demonstrates the importance of additional QA/QC protocols. This paper compares the method performance of six analytical methods used to measure 174 emer
Newborn screening for cystic fibrosis in Wisconsin: comparison of biochemical and molecular methods.
Gregg, R G; Simantel, A; Farrell, P M; Koscik, R; Kosorok, M R; Laxova, A; Laessig, R; Hoffman, G; Hassemer, D; Mischler, E H; Splaingard, M
1997-06-01
To evaluate neonatal screening for cystic fibrosis (CF), including study of the screening procedures and characteristics of false-positive infants, over the past 10 years in Wisconsin. An important objective evolving from the original design has been to compare use of a single-tier immunoreactive trypsinogen (IRT) screening method with that of a two-tier method using IRT and analyses of samples for the most common cystic fibrosis transmembrane regulator (CFTR) (DeltaF508) mutation. We also examined the benefit of including up to 10 additional CFTR mutations in the screening protocol. From 1985 to 1994, using either the IRT or IRT/DNA protocol, 220 862 and 104 308 neonates, respectively, were screened for CF. For the IRT protocol, neonates with an IRT >/=180 ng/mL were considered positive, and the standard sweat chloride test was administered to determine CF status. For the IRT/DNA protocol, samples from the original dried-blood specimen on the Guthrie card of neonates with an IRT >/=110 ng/mL were tested for the presence of the DeltaF508 CFTR allele, and if the DNA test revealed one or two DeltaF508 alleles, a sweat test was obtained. Both screening procedures had very high specificity. The sensitivity tended to be higher with the IRT/DNA protocol, but the differences were not statistically significant. The positive predictive value of the IRT/DNA screening protocol was 15.2% compared with 6.4% if the same samples had been screened by the IRT method. Assessment of the false-positive IRT/DNA population revealed that the two-tier method eliminates the disproportionate number of infants with low Apgar scores and also the high prevalence of African-Americans identified previously in our study of newborns with high IRT levels. We found that 55% of DNA-positive CF infants were homozygous for DeltaF508 and 40% had one DeltaF508 allele. Adding analyses for 10 more CFTR mutations has only a small effect on the sensitivity but is likely to add significantly to the cost of screening. Advantages of the IRT/DNA protocol over IRT analysis include improved positive predictive value, reduction of false-positive infants, and more rapid diagnosis with elimination of recall specimens.
TCP Performance Enhancement Over Iridium
NASA Technical Reports Server (NTRS)
Torgerson, Leigh; Hutcherson, Joseph; McKelvey, James
2007-01-01
In support of iNET maturation, NASA-JPL has collaborated with NASA-Dryden to develop, test and demonstrate an over-the-horizon vehicle-to-ground networking capability, using Iridium as the vehicle-to-ground communications link for relaying critical vehicle telemetry. To ensure reliability concerns are met, the Space Communications Protocol Standards (SCPS) transport protocol was investigated for its performance characteristics in this environment. In particular, the SCPS-TP software performance was compared to that of the standard Transmission Control Protocol (TCP) over the Internet Protocol (IP). This paper will report on the results of this work.
NASA Technical Reports Server (NTRS)
Blumenfeld, E. H.; Evans, C. A.; Oshel, E. R.; Liddle, D. A.; Beaulieu, K. R.; Zeigler, R. A.; Righter, K.; Hanna, R. D.; Ketcham, R. A.
2017-01-01
NASA's vast and growing collections of astromaterials are both scientifically and culturally significant, requiring unique preservation strategies that need to be recurrently updated to contemporary technological capabilities and increasing accessibility demands. New technologies have made it possible to advance documentation and visualization practices that can enhance conservation and curation protocols for NASA's Astromaterials Collections. Our interdisciplinary team has developed a method to create 3D Virtual Astromaterials Samples (VAS) of the existing collections of Apollo Lunar Samples and Antarctic Meteorites. Research-grade 3D VAS will virtually put these samples in the hands of researchers and educators worldwide, increasing accessibility and visibility of these significant collections. With new sample return missions on the horizon, it is of primary importance to develop advanced curation standards for documentation and visualization methodologies.
Leung, Gary N W; Ho, Emmie N M; Kwok, W Him; Leung, David K K; Tang, Francis P W; Wan, Terence S M; Wong, April S Y; Wong, Colton H F; Wong, Jenny K Y; Yu, Nola H
2007-09-07
Quantitative determination, particularly for threshold substances in biological samples, is much more demanding than qualitative identification. A proper assessment of any quantitative determination is the measurement uncertainty (MU) associated with the determined value. The International Standard ISO/IEC 17025, "General requirements for the competence of testing and calibration laboratories", has more prescriptive requirements on the MU than its superseded document, ISO/IEC Guide 25. Under the 2005 or 1999 versions of the new standard, an estimation of the MU is mandatory for all quantitative determinations. To comply with the new requirement, a protocol was established in the authors' laboratory in 2001. The protocol has since evolved based on our practical experience, and a refined version was adopted in 2004. This paper describes our approach in establishing the MU, as well as some other important considerations, for the quantification of threshold substances in biological samples as applied in the area of doping control for horses. The testing of threshold substances can be viewed as a compliance test (or testing to a specified limit). As such, it should only be necessary to establish the MU at the threshold level. The steps in a "Bottom-Up" approach adopted by us are similar to those described in the EURACHEM/CITAC guide, "Quantifying Uncertainty in Analytical Measurement". They involve first specifying the measurand, including the relationship between the measurand and the input quantities upon which it depends. This is followed by identifying all applicable uncertainty contributions using a "cause and effect" diagram. The magnitude of each uncertainty component is then calculated and converted to a standard uncertainty. A recovery study is also conducted to determine if the method bias is significant and whether a recovery (or correction) factor needs to be applied. All standard uncertainties with values greater than 30% of the largest one are then used to derive the combined standard uncertainty. Finally, an expanded uncertainty is calculated at 99% one-tailed confidence level by multiplying the standard uncertainty with an appropriate coverage factor (k). A sample is considered positive if the determined concentration of the threshold substance exceeds its threshold by the expanded uncertainty. In addition, other important considerations, which can have a significant impact on quantitative analyses, will be presented.
Schüler, Susann; Wenz, Ingrid; Wiederanders, B; Slickers, P; Ehricht, R
2006-06-12
Recent developments in DNA microarray technology led to a variety of open and closed devices and systems including high and low density microarrays for high-throughput screening applications as well as microarrays of lower density for specific diagnostic purposes. Beside predefined microarrays for specific applications manufacturers offer the production of custom-designed microarrays adapted to customers' wishes. Array based assays demand complex procedures including several steps for sample preparation (RNA extraction, amplification and sample labelling), hybridization and detection, thus leading to a high variability between several approaches and resulting in the necessity of extensive standardization and normalization procedures. In the present work a custom designed human proteinase DNA microarray of lower density in ArrayTube format was established. This highly economic open platform only requires standard laboratory equipment and allows the study of the molecular regulation of cell behaviour by proteinases. We established a procedure for sample preparation and hybridization and verified the array based gene expression profile by quantitative real-time PCR (QRT-PCR). Moreover, we compared the results with the well established Affymetrix microarray. By application of standard labelling procedures with e.g. Klenow fragment exo-, single primer amplification (SPA) or In Vitro Transcription (IVT) we noticed a loss of signal conservation for some genes. To overcome this problem we developed a protocol in accordance with the SPA protocol, in which we included target specific primers designed individually for each spotted oligomer. Here we present a complete array based assay in which only the specific transcripts of interest are amplified in parallel and in a linear manner. The array represents a proof of principle which can be adapted to other species as well. As the designed protocol for amplifying mRNA starts from as little as 100 ng total RNA, it presents an alternative method for detecting even low expressed genes by microarray experiments in a highly reproducible and sensitive manner. Preservation of signal integrity is demonstrated out by QRT-PCR measurements. The little amounts of total RNA necessary for the analyses make this method applicable for investigations with limited material as in clinical samples from, for example, organ or tumour biopsies. Those are arguments in favour of the high potential of our assay compared to established procedures for amplification within the field of diagnostic expression profiling. Nevertheless, the screening character of microarray data must be mentioned, and independent methods should verify the results.
Jabari, Hamidreza; Sami, Ramin; Fakhri, Mohammad; Kiani, Arda
2012-01-01
Forceps biopsy is the standard procedure to obtain specimens in endobronchial lesions. New studies have proposed flexible cryoprobe as an accepted alternative method for this technique. Although diagnostic use of the cryobiopsy is confirmed in few studies, there is paucity of data with regard to an optimum protocol for this method since one of the main considerations in cryobiopsy is the freezing time. To evaluate diagnostic yield and safety of endobronchial biopsies using the flexible cryoprobe. Moreover, different freezing times were assessed to propose an optimized protocol for this diagnostic modality. For each patient with a confirmed intrabronchial lesion, diagnostic o value of forceps biopsy, cryobiopsy in three seconds, cryobiopsy in five seconds and combined results of cryobiopsy in both timings were recorded. A total of 60 patients (39 males and 21 females; Mean age 56.7 +/- 13.3) were included. Specimens that were obtained by cryobiopsy in five seconds were significantly larger than those of forceps biopsy and cryobiopsy in three seconds (p < 0.001). We showed that the achieved diagnostic yields for all three methods were not statistically different (p > 0.05). Simultaneous usage of samples produced in both cryobiopsies can significantly improve the diagnostic yield (p = 0.02). Statistical analysis showed that there were no significant differences in case of bleeding frequency among the three sampling methods. This study confirmed safety and feasibility of cryobiopsy. Additionally, combination of sampling with two different cold induction timings would significantly increase sensitivity of this emerging technique..
Calvano, Cosima D; De Ceglie, Cristina; Zambonin, Carlo G
2014-09-01
In foodstuffs, one of the main factors inducing modifications in phospholipids (PLs) structure is the heat treatment. Among PLs, only phosphatidylethanolamines and phosphatidylserines, due to their free amino group, can be involved in Maillard reaction and can form adducts with reducing sugars, besides other by-products called advanced glycation end-products. To date, glycated lipid products are less characterized in comparison to proteins. The aim of this work was to develop a novel, rapid and sensitive extraction protocol for the detection and characterization of modified PLs (glycated and oxidized) by means of matrix-assisted laser desorption/ionization-mass spectrometry (MALDI-MS). At first, to investigate the formation of glycated and/or short chain by-products in different classes of PLs, representative standards were heated with or without sugar (lactose or glucose) and subjected to traditional lipid extraction methods as Bligh and Dyer and to the novel direct in matrix extraction (DIME) using 1,8-bis(dimethylamino)naphthalene as preconcentrating matrix. MALDI-MS analysis in negative ion mode allowed detecting glycation and oxidation products both on fatty acid and glucose moieties. Then, the procedure was successfully applied to different heat-treated and powdered samples (milk powders, pasteurized milk, ultra-high-temperature milk and soy flour) for the detection of modified PLs in complex foods. The currently developed DIME protocol could be a powerful tool for understanding lipid glycation also in biological samples. Copyright © 2014 John Wiley & Sons, Ltd.
Silva, Douglas R G; Torres Filho, Robledo A; Cazedey, Henrique P; Fontes, Paulo R; Ramos, Alcinéia L S; Ramos, Eduardo M
2015-05-01
This study was conducted to investigate the effect of core sampling on Warner-Bratzler shear force evaluations of beef and pork loins (Longissimus thoracis et lumborum muscles) and to determine the relationship between them. Steaks of 2.54 cm from beef and pork loins were cooked and five round cross-section cores and five square cross-section cores of each steak were taken for shear force evaluation. Core sampling influenced both beef and pork shear force values with higher (P<0.05) average values and standard deviations for square cross-section cores. There was a strong and linear relationship (P<0.01) between round and square cross-section cores for beef (R(2)=0.78), pork (R(2)=0.70) and for beef+pork (R(2)=0.82) samples. These results indicate that it is feasible to use square cross-section cores in Warner-Bratzler shear force protocol as an alternative and potential method to standardize sampling for shear force measurements. Copyright © 2014 Elsevier Ltd. All rights reserved.
Bourier, Felix; Reents, Tilko; Ammar-Busch, Sonia; Buiatti, Alessandra; Kottmaier, Marc; Semmler, Verena; Telishevska, Marta; Brkic, Amir; Grebmer, Christian; Lennerz, Carsten; Kolb, Christof; Hessling, Gabriele; Deisenhofer, Isabel
2016-01-01
Aims This study presents and evaluates the impact of a new lowest-dose fluoroscopy protocol (Siemens AG), especially designed for electrophysiology (EP) procedures, on X-ray dose levels. Methods and results From October 2014 to March 2015, 140 patients underwent an EP study on an Artis zee angiography system. The standard low-dose protocol was operated at 23 nGy (fluoroscopy) and at 120 nGy (cine-loop), the new lowest-dose protocol was operated at 8 nGy (fluoroscopy) and at 36 nGy (cine-loop). Procedural data, X-ray times, and doses were analysed in 100 complex left atrial and in 40 standard EP procedures. The resulting dose–area products were 877.9 ± 624.7 µGym² (n = 50 complex procedures, standard low dose), 199 ± 159.6 µGym² (n = 50 complex procedures, lowest dose), 387.7 ± 36.0 µGym² (n = 20 standard procedures, standard low dose), and 90.7 ± 62.3 µGym² (n = 20 standard procedures, lowest dose), P < 0.01. In the low-dose and lowest-dose groups, procedure times were 132.6 ± 35.7 vs. 126.7 ± 34.7 min (P = 0.40, complex procedures) and 72.3 ± 20.9 vs. 85.2 ± 44.1 min (P = 0.24, standard procedures), radiofrequency (RF) times were 53.8 ± 26.1 vs. 50.4 ± 29.4 min (P = 0.54, complex procedures) and 10.1 ± 9.9 vs. 12.2 ± 14.7 min (P = 0.60, standard procedures). One complication occurred in the standard low-dose and lowest-dose groups (P = 1.0). Conclusion The new lowest-dose imaging protocol reduces X-ray dose levels by 77% compared with the currently available standard low-dose protocol. From an operator standpoint, lowest X-ray dose levels create a different, reduced image quality. The new image quality did not significantly affect procedure or RF times and did not result in higher complication rates. Regarding radiological protection, operating at lowest-dose settings should become standard in EP procedures. PMID:26589627
Secure quantum communication using classical correlated channel
NASA Astrophysics Data System (ADS)
Costa, D.; de Almeida, N. G.; Villas-Boas, C. J.
2016-10-01
We propose a secure protocol to send quantum information from one part to another without a quantum channel. In our protocol, which resembles quantum teleportation, a sender (Alice) and a receiver (Bob) share classical correlated states instead of EPR ones, with Alice performing measurements in two different bases and then communicating her results to Bob through a classical channel. Our secure quantum communication protocol requires the same amount of classical bits as the standard quantum teleportation protocol. In our scheme, as in the usual quantum teleportation protocol, once the classical channel is established in a secure way, a spy (Eve) will never be able to recover the information of the unknown quantum state, even if she is aware of Alice's measurement results. Security, advantages, and limitations of our protocol are discussed and compared with the standard quantum teleportation protocol.
Buttner, M P; Stetzenbach, L D
1993-01-01
Aerobiological monitoring was conducted in an experimental room to aid in the development of standardized sampling protocols for airborne microorganisms in the indoor environment. The objectives of this research were to evaluate the relative efficiencies of selected sampling methods for the retrieval of airborne fungal spores and to determine the effect of human activity on air sampling. Dry aerosols containing known concentrations of Penicillium chrysogenum spores were generated, and air samples were taken by using Andersen six-stage, Surface Air System, Burkard, and depositional samplers. The Andersen and Burkard samplers retrieved the highest numbers of spores compared with the measurement standard, an aerodynamic particle sizer located inside the room. Data from paired samplers demonstrated that the Andersen sampler had the highest levels of sensitivity and repeatability. With a carpet as the source of P. chrysogenum spores, the effects of human activity (walking or vacuuming near the sampling site) on air sampling were also examined. Air samples were taken under undisturbed conditions and after human activity in the room. Human activity resulted in retrieval of significantly higher concentrations of airborne spores. Surface sampling of the carpet revealed moderate to heavy contamination despite relatively low airborne counts. Therefore, in certain situations, air sampling without concomitant surface sampling may not adequately reflect the level of microbial contamination in indoor environments. PMID:8439150
Lee, Kyung Hee; Lee, Kyung Won; Park, Ji Hoon; Han, Kyunghwa; Kim, Jihang; Lee, Sang Min; Park, Chang Min
2018-01-01
To measure inter-protocol agreement and analyze interchangeability on nodule classification between low-dose unenhanced CT and standard-dose enhanced CT. From nodule libraries containing both low-dose unenhanced and standard-dose enhanced CT, 80 solid and 80 subsolid (40 part-solid, 40 non-solid) nodules of 135 patients were selected. Five thoracic radiologists categorized each nodule into solid, part-solid or non-solid. Inter-protocol agreement between low-dose unenhanced and standard-dose enhanced images was measured by pooling κ values for classification into two (solid, subsolid) and three (solid, part-solid, non-solid) categories. Interchangeability between low-dose unenhanced and standard-dose enhanced CT for the classification into two categories was assessed using a pre-defined equivalence limit of 8 percent. Inter-protocol agreement for the classification into two categories {κ, 0.96 (95% confidence interval [CI], 0.94-0.98)} and that into three categories (κ, 0.88 [95% CI, 0.85-0.92]) was considerably high. The probability of agreement between readers with standard-dose enhanced CT was 95.6% (95% CI, 94.5-96.6%), and that between low-dose unenhanced and standard-dose enhanced CT was 95.4% (95% CI, 94.7-96.0%). The difference between the two proportions was 0.25% (95% CI, -0.85-1.5%), wherein the upper bound CI was markedly below 8 percent. Inter-protocol agreement for nodule classification was considerably high. Low-dose unenhanced CT can be used interchangeably with standard-dose enhanced CT for nodule classification.
SPIRIT 2013 Statement: defining standard protocol items for clinical trials.
Chan, An-Wen; Tetzlaff, Jennifer M; Altman, Douglas G; Laupacis, Andreas; Gøtzsche, Peter C; Krle A-Jerić, Karmela; Hrobjartsson, Asbjørn; Mann, Howard; Dickersin, Kay; Berlin, Jesse A; Dore, Caroline J; Parulekar, Wendy R; Summerskill, William S M; Groves, Trish; Schulz, Kenneth F; Sox, Harold C; Rockhold, Frank W; Rennie, Drummond; Moher, David
2015-12-01
The protocol of a clinical trial serves as the foundation for study planning, conduct, reporting, and appraisal. However, trial protocols and existing protocol guidelines vary greatly in content and quality. This article describes the systematic development and scope of SPIRIT (Standard Protocol Items: Recommendations for Interventional Trials) 2013, a guideline for the minimum content of a clinical trial protocol. The 33-item SPIRIT checklist applies to protocols for all clinical trials and focuses on content rather than format. The checklist recommends a full description of what is planned; it does not prescribe how to design or conduct a trial. By providing guidance for key content, the SPIRIT recommendations aim to facilitate the drafting of high-quality protocols. Adherence to SPIRIT would also enhance the transparency and completeness of trial protocols for the benefit of investigators, trial participants, patients, sponsors, funders, research ethics committees or institutional review boards, peer reviewers, journals, trial registries, policymakers, regulators, and other key stakeholders.
SPIRIT 2013 Statement: Defining Standard Protocol Items for Clinical Trials
Chan, An-Wen; Tetzlaff, Jennifer M.; Altman, Douglas G.; Laupacis, Andreas; Gøtzsche, Peter C.; Krleža-Jerić, Karmela; Hróbjartsson, Asbjørn; Mann, Howard; Dickersin, Kay; Berlin, Jesse A.; Doré, Caroline J.; Parulekar, Wendy R.; Summerskill, William S.M.; Groves, Trish; Schulz, Kenneth F.; Sox, Harold C.; Rockhold, Frank W.; Rennie, Drummond; Moher, David
2016-01-01
The protocol of a clinical trial serves as the foundation for study planning, conduct, reporting, and appraisal. However, trial protocols and existing protocol guidelines vary greatly in content and quality. This article describes the systematic development and scope of SPIRIT (Standard Protocol Items: Recommendations for Interventional Trials) 2013, a guideline for the minimum content of a clinical trial protocol. The 33-item SPIRIT checklist applies to protocols for all clinical trials and focuses on content rather than format. The checklist recommends a full description of what is planned; it does not prescribe how to design or conduct a trial. By providing guidance for key content, the SPIRIT recommendations aim to facilitate the drafting of high-quality protocols. Adherence to SPIRIT would also enhance the transparency and completeness of trial protocols for the benefit of investigators, trial participants, patients, sponsors, funders, research ethics committees or institutional review boards, peer reviewers, journals, trial registries, policymakers, regulators, and other key stakeholders. PMID:23295957
SPIRIT 2013 statement: defining standard protocol items for clinical trials.
Chan, An-Wen; Tetzlaff, Jennifer M; Altman, Douglas G; Laupacis, Andreas; Gøtzsche, Peter C; Krleža-Jerić, Karmela; Hróbjartsson, Asbjørn; Mann, Howard; Dickersin, Kay; Berlin, Jesse A; Doré, Caroline J; Parulekar, Wendy R; Summerskill, William S M; Groves, Trish; Schulz, Kenneth F; Sox, Harold C; Rockhold, Frank W; Rennie, Drummond; Moher, David
2013-02-05
The protocol of a clinical trial serves as the foundation for study planning, conduct, reporting, and appraisal. However, trial protocols and existing protocol guidelines vary greatly in content and quality. This article describes the systematic development and scope of SPIRIT (Standard Protocol Items: Recommendations for Interventional Trials) 2013, a guideline for the minimum content of a clinical trial protocol.The 33-item SPIRIT checklist applies to protocols for all clinical trials and focuses on content rather than format. The checklist recommends a full description of what is planned; it does not prescribe how to design or conduct a trial. By providing guidance for key content, the SPIRIT recommendations aim to facilitate the drafting of high-quality protocols. Adherence to SPIRIT would also enhance the transparency and completeness of trial protocols for the benefit of investigators, trial participants, patients, sponsors, funders, research ethics committees or institutional review boards, peer reviewers, journals, trial registries, policymakers, regulators, and other key stakeholders.
Schenk, Michael; Huppertz, Berthold; Obermayer-Pietsch, Barbara; Kastelic, Darja; Hörmann-Kröpfl, Martina; Weiss, Gregor
2017-02-01
The aim of the present study was to develop a standard operating procedure (SOP) for the collection, transport, and storage of human cumulus cells, follicular fluid, blood serum, seminal plasma, embryo culture supernatant, and embryo culture supernatant control obtained within the IVF process under approved protocols and written informed consent from participating patients. The SOP was developed at the Kinderwunsch Institut Schenk, Dobl, Austria, together with Biobank Graz of the Medical University of Graz, Austria. The SOP provides comprehensive details of laboratory procedures and sampling of the different fluids within the IVF process. Furthermore, information on sample coding, references of involved laboratory techniques (e.g., oocyte retrieval with a Steiner-TAN needle), ethical approvals, and biobanking procedures are presented. The result of the present study is a standard operating procedure. The SOP ensures a professional way for collection and scientific use of IVF samples by the Kinderwunsch Institut Schenk, Dobl, Austria, and Biobank Graz of the Medical University of Graz, Austria. It can be used as a template for other institutions to unify specimen collection procedures in the field of reproductive health research.
Bires, Angela Macci; Lawson, Dori; Wasser, Thomas E; Raber-Baer, Donna
2013-12-01
Clinically valid cardiac evaluation via treadmill stress testing requires patients to achieve specific target heart rates and to successfully complete the cardiac examination. A comparison of the standard Bruce protocol and the ramped Bruce protocol was performed using data collected over a 1-y period from a targeted patient population with a body mass index (BMI) equal to or greater than 30 to determine which treadmill protocol provided more successful examination results. The functional capacity, metabolic equivalent units achieved, pressure rate product, and total time on the treadmill as measured for the obese patients were clinically valid and comparable to normal-weight and overweight patients (P < 0.001). Data gathered from each protocol demonstrated that the usage of the ramped Bruce protocol achieved more consistent results in comparison across all BMI groups in achieving 80%-85% of their age-predicted maximum heart rate. This study did not adequately establish that the ramped Bruce protocol was superior to the standard Bruce protocol for the examination of patients with a BMI equal to or greater than 30.
Hladik, Michelle; Orlando, James L.; Kuivila, Kathryn
2009-01-01
Loss of pyrethroid insecticides onto surfaces during sample collection can confound the interpretation of analytical and toxicity test results. Sample collection devices, container materials, and water matrix composition have a significant influence on the association of pyrethroids to container walls, which can be as high as 50 percent. Any sample collection method involving transfer through multiple containers or pieces of equipment increases the potential for pyrethroid loss. This loose 'surface-association' with container walls can be reversed through agitation. When sampling water matrices with pumps or autosamplers, no pyrethroids were lost as long as the water was moving continuously through the system. When collecting water matrices in containers, the material with the least amount of pyrethroid sorption is as follows: glass less than (<) plastic less than (<) Teflon. Additionally, pyrethroids were easier to re-suspend from the glass container walls. Since the amount of surface-association is proportional to the ratio of volume-to-contact-area of the sample, taking larger-volume field samples (greater than 3 liters) reduced pyrethroid losses to less than 10 percent. The amount of surface-association cannot be predicted easily because of the dependence on water matrix composition; samples with higher dissolved organic carbon or suspended-sediment concentrations were observed to have lower percent loss. Sediment samples were not affected by glass-container sorption (the only containers tested). Standardized sample-collection protocols are critical to yield accurate pyrethroid concentrations for assessment of potential effects, and have been summarized in an accompanying standard operating procedure.
Specificity of coliphages in evaluating marker efficacy: a new insight for water quality indicators.
Mookerjee, Subham; Batabyal, Prasenjit; Halder, Madhumanti; Palit, Anup
2014-11-01
Conventional procedures for qualitative assessment of coliphage are time consuming multiple step approach for achieving results. A modified and rapid technique has been introduced for determination of coliphage contamination among potable water sources during water borne outbreaks. During December 2013, 40 water samples from different potable water sources, were received for water quality analyses, from a jaundice affected Municipality of West Bengal, India. Altogether, 30% water samples were contaminated with coliform (1-20 cfu/ml) and 5% with E. coli (2-5 cfu/ml). Among post-outbreak samples, preponderance of coliform has decreased (1-4 cfu/ml) with total absence of E. coli. While standard technique has detected 55% outbreak samples with coliphage contamination, modified technique revealed that 80%, double than that of bacteriological identification rate, were contaminated with coliphages (4-20 pfu/10 ml). However, post-outbreak samples were detected with 1-5 pfu/10 ml coliphages among 20% samples. Coliphage detection rate through modified technique was nearly double (50%) than that of standard technique (27.5%). In few samples (with coliform load of 10-100 cfu/ml), while modified technique could detect coliphages among six samples (10-20 pfu/10 ml), standard protocol failed to detect coliphage in any of them. An easy, rapid and accurate modified technique has thereby been implemented for coliphage assessment from water samples. Coliform free water does not always signify pathogen free potable water and it is demonstrated that coliphage is a more reliable 'biomarker' to ascertain contamination level in potable water. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Raju, Kota Solomon; Merugu, Naresh Babu; Neetu, Babu, E. Ram
2016-03-01
ZigBee is well-accepted industrial standard for wireless sensor networks based on IEEE 802.15.4 standard. Wireless Sensor Networks is the major concern of communication these days. These Wireless Sensor Networks investigate the properties of networks of small battery-powered sensors with wireless communication. The communication between any two wireless nodes of wireless sensor networks is carried out through a protocol stack. This protocol stack has been designed by different vendors in various ways. Every custom vendor possesses his own protocol stack and algorithms especially at the MAC layer. But, many applications require modifications in their algorithms at various layers as per their requirements, especially energy efficient protocols at MAC layer that are simulated in Wireless sensor Network Simulators which are not being tested in real time systems because vendors do not allow the programmability of each layer in their protocol stack. This problem can be quoted as Vendor-Interoperability. The solution is to develop the programmable protocol stack where we can design our own application as required. As a part of the task first we tried implementing physical layer and transmission of data using physical layer. This paper describes about the transmission of the total number of bytes of Frame according to the IEEE 802.15.4 standard using Physical Layer.
Ilyin, S E; Plata-Salamán, C R
2000-02-15
Homogenization of tissue samples is a common first step in the majority of current protocols for RNA, DNA, and protein isolation. This report describes a simple device for centrifugation-mediated homogenization of tissue samples. The method presented is applicable to RNA, DNA, and protein isolation, and we show examples where high quality total cell RNA, DNA, and protein were obtained from brain and other tissue samples. The advantages of the approach presented include: (1) a significant reduction in time investment relative to hand-driven or individual motorized-driven pestle homogenization; (2) easy construction of the device from inexpensive parts available in any laboratory; (3) high replicability in the processing; and (4) the capacity for the parallel processing of multiple tissue samples, thus allowing higher efficiency, reliability, and standardization.
Sheldon, Elizabeth; Vo, Kim Chi; McIntire, Ramsey A; Aghajanova, Lusine; Zelenko, Zara; Irwin, Juan C; Giudice, Linda C
2011-05-01
To develop a standard operating procedure (SOP) for collection, transport, storage of human endometrial tissue and blood samples, subject and specimen annotation, and establishing sample priorities. The SOP synthesizes sound scientific procedures, the literature on ischemia research, sample collection and gene expression profiling, good laboratory practices, and the authors' experience of workflow and sample quality. The National Institutes of Health, University of California, San Francisco, Human Endometrial Tissue and DNA Bank. Women undergoing endometrial biopsy or hysterectomy for nonmalignant indications. Collecting, processing, storing, distributing endometrial tissue and blood samples under approved institutional review board protocols and written informed consent from participating subjects. Standard operating procedure. The SOP addresses rigorous and consistent subject annotation, specimen processing and characterization, strict regulatory compliance, and a reference for researchers to track collection and storage times that may influence their research. The comprehensive and systematic approach to the procurement of human blood and endometrial tissue in this SOP ensures the high quality, reliability, and scientific usefulness of biospecimens made available to investigators by the National Institutes of Health, University of California, San Francisco, Human Endometrial Tissue and DNA Bank. The detail and perspective in this SOP also provides a blueprint for implementation of similar collection programs at other institutions. Copyright © 2011 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
CURRENT STATUS OF THE EPA PROTOCOL GAS PROGRAM
Accurate compressed gas calibration standards are needed to calibrate continuous emission monitors (CEMs) and ambient air quality monitors that are being used for regulatory purposes. EPA has published a protocol to establish the traceability of these standards to national refer...
Using the ACR/NEMA standard with TCP/IP and Ethernet
NASA Astrophysics Data System (ADS)
Chimiak, William J.; Williams, Rodney C.
1991-07-01
There is a need for a consolidated picture archival and communications system (PACS) in hospitals. At the Bowman Gray School of Medicine of Wake Forest University (BGSM), the authors are enhancing the ACR/NEMA Version 2 protocol using UNIX sockets and TCP/IP to greatly improve connectivity. Initially, nuclear medicine studies using gamma cameras are to be sent to PACS. The ACR/NEMA Version 2 protocol provides the functionality of the upper three layers of the open system interconnection (OSI) model in this implementation. The images, imaging equipment information, and patient information are then sent in ACR/NEMA format to a software socket. From there it is handed to the TCP/IP protocol, which provides the transport and network service. TCP/IP, in turn, uses the services of IEEE 802.3 (Ethernet) to complete the connectivity. The advantage of this implementation is threefold: (1) Only one I/O port is consumed by numerous nuclear medicine cameras, instead of a physical port for each camera. (2) Standard protocols are used which maximize interoperability with ACR/NEMA compliant PACSs. (3) The use of sockets allows a migration path to the transport and networking services of OSIs TP4 and connectionless network service as well as the high-performance protocol being considered by the American National Standards Institute (ANSI) and the International Standards Organization (ISO) -- the Xpress Transfer Protocol (XTP). The use of sockets also gives access to ANSI's Fiber Distributed Data Interface (FDDI) as well as other high-speed network standards.
A 'smart' tube holder enables real-time sample monitoring in a standard lab centrifuge.
Hoang, Tony; Moskwa, Nicholas; Halvorsen, Ken
2018-01-01
The centrifuge is among the oldest and most widely used pieces of laboratory equipment, with significant applications that include clinical diagnostics and biomedical research. A major limitation of laboratory centrifuges is their "black box" nature, limiting sample observation to before and after centrifugation. Thus, optimized protocols require significant trial and error, while unoptimized protocols waste time by centrifuging longer than necessary or material due to incomplete sedimentation. Here, we developed an instrumented centrifuge tube receptacle compatible with several commercial benchtop centrifuges that can provide real-time sample analysis during centrifugation. We demonstrated the system by monitoring cell separations during centrifugation for different spin speeds, concentrations, buffers, cell types, and temperatures. We show that the collected data are valuable for analytical purposes (e.g. quality control), or as feedback to the user or the instrument. For the latter, we verified an adaptation where complete sedimentation turned off the centrifuge and notified the user by a text message. Our system adds new functionality to existing laboratory centrifuges, saving users time and providing useful feedback. This add-on potentially enables new analytical applications for an instrument that has remained largely unchanged for decades.
A ‘smart’ tube holder enables real-time sample monitoring in a standard lab centrifuge
Hoang, Tony; Moskwa, Nicholas
2018-01-01
The centrifuge is among the oldest and most widely used pieces of laboratory equipment, with significant applications that include clinical diagnostics and biomedical research. A major limitation of laboratory centrifuges is their “black box” nature, limiting sample observation to before and after centrifugation. Thus, optimized protocols require significant trial and error, while unoptimized protocols waste time by centrifuging longer than necessary or material due to incomplete sedimentation. Here, we developed an instrumented centrifuge tube receptacle compatible with several commercial benchtop centrifuges that can provide real-time sample analysis during centrifugation. We demonstrated the system by monitoring cell separations during centrifugation for different spin speeds, concentrations, buffers, cell types, and temperatures. We show that the collected data are valuable for analytical purposes (e.g. quality control), or as feedback to the user or the instrument. For the latter, we verified an adaptation where complete sedimentation turned off the centrifuge and notified the user by a text message. Our system adds new functionality to existing laboratory centrifuges, saving users time and providing useful feedback. This add-on potentially enables new analytical applications for an instrument that has remained largely unchanged for decades. PMID:29659624
Dey-Hazra, Emily; Hertel, Barbara; Kirsch, Torsten; Woywodt, Alexander; Lovric, Svjetlana; Haller, Hermann; Haubitz, Marion; Erdbruegger, Uta
2010-01-01
The clinical importance of microparticles resulting from vesiculation of platelets and other blood cells is increasingly recognized, although no standardized method exists for their measurement. Only a few studies have examined the analytical and preanalytical steps and variables affecting microparticle detection. We focused our analysis on microparticle detection by flow cytometry. The goal of our study was to analyze the effects of different centrifugation protocols looking at different durations of high and low centrifugation speeds. We also analyzed the effect of filtration of buffer and long-term freezing on microparticle quantification, as well as the role of Annexin V in the detection of microparticles. Absolute and platelet-derived microparticles were 10- to 15-fold higher using initial lower centrifugation speeds at 1500 × g compared with protocols using centrifugation speeds at 5000 × g (P < 0.01). A clear separation between true events and background noise was only achieved using higher centrifugation speeds. Filtration of buffer with a 0.2 μm filter reduced a significant amount of background noise. Storing samples for microparticle detection at −80°C decreased microparticle levels at days 28, 42, and 56 (P < 0.05 for all comparisons with fresh samples). We believe that staining with Annexin V is necessary to distinguish true events from cell debris or precipitates. Buffers should be filtered and fresh samples should be analyzed, or storage periods will have to be standardized. Higher centrifugation speeds should be used to minimize contamination by smaller size platelets. PMID:21191433
Yang, Min; Chen, Pei-Yu; Gong, Si-Tang; Lyman, Beth; Geng, Lan-Lan; Liu, Li-Ying; Liang, Cui-Ping; Xu, Zhao-Hui; Li, Hui-Wen; Fang, Tie-Fu; Li, Ding-You
2014-11-01
A standard nutrition screening and enteral nutrition (EN) protocol was implemented in January 2012 in a tertiary children's center in China. The aims of the present study were to evaluate the cost-effectiveness of a standard EN protocol in hospitalized patients. A retrospective chart review was performed in the gastroenterology inpatient unit. We included all inpatient children requiring EN from January 1, 2010, to December 31, 2013, with common gastrointestinal (GI) diseases. Children from January 1, 2012, to December 31, 2013, served as the standard EN treatment group, and those from January 1, 2010, to December 31, 2011, were the control EN group. Pertinent patient information was collected. We also analyzed the length of hospital stay, cost of care, and in-hospital infection rates. The standard EN treatment group received more nasojejunal tube feedings. There was a tendency for the standard EN treatment group to receive more elemental and hydrolyzed protein formulas. Implementation of a standard EN protocol significantly reduced the time to initiate EN (32.38 ± 24.50 hours vs 18.76 ± 13.53 hours; P = .011) and the time to reach a targeted calorie goal (7.42 ± 3.98 days vs 5.06 ± 3.55 days; P = .023); length of hospital stay was shortened by 3.2 days after implementation of the standard EN protocol but did not reach statistical significance. However, the shortened length of hospital stay contributed to a significant reduction in the total cost of hospital care (13,164.12 ± 6722.95 Chinese yuan [CNY] vs 9814.96 ± 4592.91 CNY; P < .032). Implementation of a standard EN protocol resulted in early initiation of EN, shortened length of stay, and significantly reduced total cost of care in hospitalized children with common GI diseases. © 2014 American Society for Parenteral and Enteral Nutrition.
A Weak Value Based QKD Protocol Robust Against Detector Attacks
NASA Astrophysics Data System (ADS)
Troupe, James
2015-03-01
We propose a variation of the BB84 quantum key distribution protocol that utilizes the properties of weak values to insure the validity of the quantum bit error rate estimates used to detect an eavesdropper. The protocol is shown theoretically to be secure against recently demonstrated attacks utilizing detector blinding and control and should also be robust against all detector based hacking. Importantly, the new protocol promises to achieve this additional security without negatively impacting the secure key generation rate as compared to that originally promised by the standard BB84 scheme. Implementation of the weak measurements needed by the protocol should be very feasible using standard quantum optical techniques.
A new gold standard approach to characterize the transport of Si across cell membranes in animals.
Garneau, Alexandre P; Marcoux, Andrée-Anne; Frenette-Cotton, Rachelle; Bélanger, Richard; Isenring, Paul
2018-01-11
Silicon (Si) is increasingly recognized as an essential trace element in animals, especially since the identification of mammalian Si transport systems and Si responsive genes not long ago. During many years, however, efforts to gain substantial insight into the biological role of this element in animals have achieved partial success due in part to the unavailability of validated protocols to study Si movement across biological membranes. To circumvent such limitations, we have developed a general transport assay in which cellular Si content was determined by automated electrothermal atomic absorption spectrophotometry. We have found this assay to provide great analytic sensitivity with Si detection thresholds of less than 1 µM, that is, below or very close to the concentration range of animal cells. We have also found this assay to provide valid and cost-effective determinations in Si transport studies while requiring workable quantities of samples. The protocol described here should thus become gold standard toward accelerated progress in the field of Si transport. © 2018 Wiley Periodicals, Inc.
The Virtual Insect Brain protocol: creating and comparing standardized neuroanatomy
Jenett, Arnim; Schindelin, Johannes E; Heisenberg, Martin
2006-01-01
Background In the fly Drosophila melanogaster, new genetic, physiological, molecular and behavioral techniques for the functional analysis of the brain are rapidly accumulating. These diverse investigations on the function of the insect brain use gene expression patterns that can be visualized and provide the means for manipulating groups of neurons as a common ground. To take advantage of these patterns one needs to know their typical anatomy. Results This paper describes the Virtual Insect Brain (VIB) protocol, a script suite for the quantitative assessment, comparison, and presentation of neuroanatomical data. It is based on the 3D-reconstruction and visualization software Amira, version 3.x (Mercury Inc.) [1]. Besides its backbone, a standardization procedure which aligns individual 3D images (series of virtual sections obtained by confocal microscopy) to a common coordinate system and computes average intensities for each voxel (volume pixel) the VIB protocol provides an elaborate data management system for data administration. The VIB protocol facilitates direct comparison of gene expression patterns and describes their interindividual variability. It provides volumetry of brain regions and helps to characterize the phenotypes of brain structure mutants. Using the VIB protocol does not require any programming skills since all operations are carried out at an intuitively usable graphical user interface. Although the VIB protocol has been developed for the standardization of Drosophila neuroanatomy, the program structure can be used for the standardization of other 3D structures as well. Conclusion Standardizing brains and gene expression patterns is a new approach to biological shape and its variability. The VIB protocol provides a first set of tools supporting this endeavor in Drosophila. The script suite is freely available at [2] PMID:17196102
Rethinking the NTCIP Design and Protocols - Analyzing the Issues
DOT National Transportation Integrated Search
1998-03-03
This working paper discusses the issues involved in changing the current draft NTCIP standard from an X.25-based protocol stack to an Internet-based protocol stack. It contains a methodology which could be used to change NTCIP's base protocols. This ...
Song, Young Kyoung; Hong, Sang Hee; Jang, Mi; Han, Gi Myung; Rani, Manviri; Lee, Jongmyoung; Shim, Won Joon
2015-04-15
The analysis of microplastics in various environmental samples requires the identification of microplastics from natural materials. The identification technique lacks a standardized protocol. Herein, stereomicroscope and Fourier transform infrared spectroscope (FT-IR) identification methods for microplastics (<1mm) were compared using the same samples from the sea surface microlayer (SML) and beach sand. Fragmented microplastics were significantly (p<0.05) underestimated and fiber was significantly overestimated using the stereomicroscope both in the SML and beach samples. The total abundance by FT-IR was higher than by microscope both in the SML and beach samples, but they were not significantly (p>0.05) different. Depending on the number of samples and the microplastic size range of interest, the appropriate identification method should be determined; selecting a suitable identification method for microplastics is crucial for evaluating microplastic pollution. Copyright © 2015 Elsevier Ltd. All rights reserved.
Low-power, low-cost urinalysis system with integrated dipstick evaluation and microscopic analysis.
Smith, Gennifer T; Li, Linkai; Zhu, Yue; Bowden, Audrey K
2018-06-21
We introduce a coupled dipstick and microscopy device for analyzing urine samples. The device is capable of accurately assessing urine dipstick results while simultaneously imaging the microscopic contents within the sample. We introduce a long working distance, cellphone-based microscope in combination with an oblique illumination scheme to accurately visualize and quantify particles within the urine sample. To facilitate accurate quantification, we couple the imaging set-up with a power-free filtration system. The proposed device is reusable, low-cost, and requires very little power. We show that results obtained with the proposed device and custom-built app are consistent with those obtained with the standard clinical protocol, suggesting the potential clinical utility of the device.
Tegel, Hanna; Yderland, Louise; Boström, Tove; Eriksson, Cecilia; Ukkonen, Kaisa; Vasala, Antti; Neubauer, Peter; Ottosson, Jenny; Hober, Sophia
2011-08-01
Protein production and analysis in a parallel fashion is today applied in laboratories worldwide and there is a great need to improve the techniques and systems used for this purpose. In order to save time and money, a fast and reliable screening method for analysis of protein production and also verification of the protein product is desired. Here, a micro-scale protocol for the parallel production and screening of 96 proteins in plate format is described. Protein capture was achieved using immobilized metal affinity chromatography and the product was verified using matrix-assisted laser desorption ionization time-of-flight MS. In order to obtain sufficiently high cell densities and product yield in the small-volume cultivations, the EnBase® cultivation technology was applied, which enables cultivation in as small volumes as 150 μL. Here, the efficiency of the method is demonstrated by producing 96 human, recombinant proteins, both in micro-scale and using a standard full-scale protocol and comparing the results in regard to both protein identity and sample purity. The results obtained are highly comparable to those acquired through employing standard full-scale purification protocols, thus validating this method as a successful initial screening step before protein production at a larger scale. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Kim, Kwan-Ii; Jo, Junyoung
2018-01-01
Male factor subfertility has increasingly been considered the cause of infertility in couples. Many men with male infertility have sperm problems such as oligozoospermia, asthenozoospermia, or teratozoospermia. Because abnormal semen parameters are idiopathic to some extent, no standard therapy has been established to date. Herbal medicine has been reported to have beneficial properties in the treatment of subfertility, especially in improving semen quality both in vivo and in human studies. Therefore, we intend to investigate the effectiveness and safety of treatment using Korean medicine (KM) for infertile male patients with poor semen quality.This will be a single-center, prospective, case-only observational pilot study. About 20 male patients with infertility who visit Conmaul Hospital of Korean Medicine will be recruited. We will follow the standard treatment protocol, which has shown good results in the treatment of male infertility. The protocol is composed mainly of a 10-week herbal decoction treatment; acupuncture and/or pharmacopuncture are added when needed. Semen samples, quality of life, and the scrotal temperatures of infertile men will be observed before and after the 10-week treatment with KM.The study has received ethical approval from the Public Institutional Review Board (approval number: P01-201708-21-008). The findings will be disseminated to appropriate audiences via peer-reviewed publication and conference presentations. Korean Clinical Trial Registry (CRIS), Republic of Korea: KCT0002611.
Aiello, Roberta; Zecchin, Barbara; Tiozzo Caenazzo, Silvia; Cattoli, Giovanni; De Benedictis, Paola
2016-08-01
In the last decades, molecular techniques have gradually been adopted for the rapid confirmation of results obtained through gold standard methods. However, international organisations discourage their use in routine laboratory investigations for rabies post-mortem diagnosis, as they may lead to false positive results due to cross-contamination. Cleaning and disinfection are essential to prevent cross-contamination of samples in the laboratory environment. The present study evaluated the efficacy of selected disinfectants on rabies-contaminated necropsy equipment under organic challenge using a carrier-based test. The occurrence of detectable Rabies virus (RABV) antigen, viable virus and RNA was assessed through the gold standard Fluorescent Antibody Test, the Rabies Tissue Culture Infection Test and molecular techniques, respectively. None of the tested disinfectants proved to be effective under label conditions. Off label disinfection protocols were found effective for oxidizing agents and phenolic, only. Biguanide and quaternary ammonium compound were both ineffective under all tested conditions. Overall, discordant results were obtained when different diagnostic tests were compared, which means that in the presence of organic contamination common disinfectants may not be effective enough on viable RABV or RNA. Our results indicate that an effective disinfection protocol should be carefully validated to guarantee staff safety and reliability of results. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
A multigear protocol for sampling crayfish assemblages in Gulf of Mexico coastal streams
William R. Budnick; William E. Kelso; Susan B. Adams; Michael D. Kaller
2018-01-01
Identifying an effective protocol for sampling crayfish in streams that vary in habitat and physical/chemical characteristics has proven problematic. We evaluated an active, combined-gear (backpack electrofishing and dipnetting) sampling protocol in 20 Coastal Plain streams in Louisiana. Using generalized linear models and rarefaction curves, we evaluated environmental...
Souza, C A; Oliveira, T C; Crovella, S; Santos, S M; Rabêlo, K C N; Soriano, E P; Carvalho, M V D; Junior, A F Caldas; Porto, G G; Campello, R I C; Antunes, A A; Queiroz, R A; Souza, S M
2017-04-28
The use of Y chromosome haplotypes, important for the detection of sexual crimes in forensics, has gained prominence with the use of databases that incorporate these genetic profiles in their system. Here, we optimized and validated an amplification protocol for Y chromosome profile retrieval in reference samples using lesser materials than those in commercial kits. FTA ® cards (Flinders Technology Associates) were used to support the oral cells of male individuals, which were amplified directly using the SwabSolution reagent (Promega). First, we optimized and validated the process to define the volume and cycling conditions. Three reference samples and nineteen 1.2 mm-diameter perforated discs were used per sample. Amplification of one or two discs (samples) with the PowerPlex ® Y23 kit (Promega) was performed using 25, 26, and 27 thermal cycles. Twenty percent, 32%, and 100% reagent volumes, one disc, and 26 cycles were used for the control per sample. Thereafter, all samples (N = 270) were amplified using 27 cycles, one disc, and 32% reagents (optimized conditions). Data was analyzed using a study of equilibrium values between fluorophore colors. In the samples analyzed with 20% volume, an imbalance was observed in peak heights, both inside and in-between each dye. In samples amplified with 32% reagents, the values obtained for the intra-color and inter-color standard balance calculations for verification of the quality of the analyzed peaks were similar to those of samples amplified with 100% of the recommended volume. The quality of the profiles obtained with 32% reagents was suitable for insertion into databases.
Comparison of EPA Method 1615 RT-qPCR Assays in Standard and Kit Format
EPA Method 1615 contains protocols for measuring enterovirus and norovirus by reverse transcription quantitative polymerase chain reaction. A commercial kit based upon these protocols was designed and compared to the method's standard approach. Reagent grade, secondary effluent, ...
Colloidal Fouling of Nanofiltration Membranes: Development of a Standard Operating Procedure
Al Mamun, Md Abdullaha; Bhattacharjee, Subir; Pernitsky, David; Sadrzadeh, Mohtada
2017-01-01
Fouling of nanofiltration (NF) membranes is the most significant obstacle to the development of a sustainable and energy-efficient NF process. Colloidal fouling and performance decline in NF processes is complex due to the combination of cake formation and salt concentration polarization effects, which are influenced by the properties of the colloids and the membrane, the operating conditions of the test, and the solution chemistry. Although numerous studies have been conducted to investigate the influence of these parameters on the performance of the NF process, the importance of membrane preconditioning (e.g., compaction and equilibrating with salt water), as well as the determination of key parameters (e.g., critical flux and trans-membrane osmotic pressure) before the fouling experiment have not been reported in detail. The aim of this paper is to present a standard experimental and data analysis protocol for NF colloidal fouling experiments. The developed methodology covers preparation and characterization of water samples and colloidal particles, pre-test membrane compaction and critical flux determination, measurement of experimental data during the fouling test, and the analysis of that data to determine the relative importance of various fouling mechanisms. The standard protocol is illustrated with data from a series of flat sheet, bench-scale experiments. PMID:28106775
Motosugi, Utaroh; Hernando, Diego; Wiens, Curtis; Bannas, Peter; Reeder, Scott. B
2017-01-01
Purpose: To determine whether high signal-to-noise ratio (SNR) acquisitions improve the repeatability of liver proton density fat fraction (PDFF) measurements using confounder-corrected chemical shift-encoded magnetic resonance (MR) imaging (CSE-MRI). Materials and Methods: Eleven fat-water phantoms were scanned with 8 different protocols with varying SNR. After repositioning the phantoms, the same scans were repeated to evaluate the test-retest repeatability. Next, an in vivo study was performed with 20 volunteers and 28 patients scheduled for liver magnetic resonance imaging (MRI). Two CSE-MRI protocols with standard- and high-SNR were repeated to assess test-retest repeatability. MR spectroscopy (MRS)-based PDFF was acquired as a standard of reference. The standard deviation (SD) of the difference (Δ) of PDFF measured in the two repeated scans was defined to ascertain repeatability. The correlation between PDFF of CSE-MRI and MRS was calculated to assess accuracy. The SD of Δ and correlation coefficients of the two protocols (standard- and high-SNR) were compared using F-test and t-test, respectively. Two reconstruction algorithms (complex-based and magnitude-based) were used for both the phantom and in vivo experiments. Results: The phantom study demonstrated that higher SNR improved the repeatability for both complex- and magnitude-based reconstruction. Similarly, the in vivo study demonstrated that the repeatability of the high-SNR protocol (SD of Δ = 0.53 for complex- and = 0.85 for magnitude-based fit) was significantly higher than using the standard-SNR protocol (0.77 for complex, P < 0.001; and 0.94 for magnitude-based fit, P = 0.003). No significant difference was observed in the accuracy between standard- and high-SNR protocols. Conclusion: Higher SNR improves the repeatability of fat quantification using confounder-corrected CSE-MRI. PMID:28190853
Abras, Alba; Ballart, Cristina; Llovet, Teresa; Roig, Carme; Gutiérrez, Cristina; Tebar, Silvia; Berenguer, Pere; Pinazo, María-Jesús; Posada, Elizabeth; Gascón, Joaquim; Schijman, Alejandro G; Gállego, Montserrat; Muñoz, Carmen
2018-01-01
Polymerase chain reaction (PCR) has become a useful tool for the diagnosis of Trypanosoma cruzi infection. The development of automated DNA extraction methodologies and PCR systems is an important step toward the standardization of protocols in routine diagnosis. To date, there are only two commercially available Real-Time PCR assays for the routine laboratory detection of T. cruzi DNA in clinical samples: TCRUZIDNA.CE (Diagnostic Bioprobes Srl) and RealCycler CHAG (Progenie Molecular). Our aim was to evaluate the RealCycler CHAG assay taking into account the whole process. We assessed the usefulness of an automated DNA extraction system based on magnetic particles (EZ1 Virus Mini Kit v2.0, Qiagen) combined with a commercially available Real-Time PCR assay targeting satellite DNA (SatDNA) of T. cruzi (RealCycler CHAG), a methodology used for routine diagnosis in our hospital. It was compared with a well-known strategy combining a commercial DNA isolation kit based on silica columns (High Pure PCR Template Preparation Kit, Roche Diagnostics) with an in-house Real-Time PCR targeting SatDNA. The results of the two methodologies were in almost perfect agreement, indicating they can be used interchangeably. However, when variations in protocol factors were applied (sample treatment, extraction method and Real-Time PCR), the results were less convincing. A comprehensive fine-tuning of the whole procedure is the key to successful results. Guanidine EDTA-blood (GEB) samples are not suitable for DNA extraction based on magnetic particles due to inhibition, at least when samples are not processed immediately. This is the first study to evaluate the RealCycler CHAG assay taking into account the overall process, including three variables (sample treatment, extraction method and Real-Time PCR). Our findings may contribute to the harmonization of protocols between laboratories and to a wider application of Real-Time PCR in molecular diagnostic laboratories associated with health centers.
Laser capture microdissection of embryonic cells and preparation of RNA for microarray assays.
Redmond, Latasha C; Pang, Christopher J; Dumur, Catherine; Haar, Jack L; Lloyd, Joyce A
2014-01-01
In order to compare the global gene expression profiles of different embryonic cell types, it is first necessary to isolate the specific cells of interest. The purpose of this chapter is to provide a step-by-step protocol to perform laser capture microdissection (LCM) on embryo samples and obtain sufficient amounts of high-quality RNA for microarray hybridizations. Using the LCM/microarray strategy on mouse embryo samples has some challenges, because the cells of interest are available in limited quantities. The first step in the protocol is to obtain embryonic tissue, and immediately cryoprotect and freeze it in a cryomold containing Optimal Cutting Temperature freezing media (Sakura Finetek), using a dry ice-isopentane bath. The tissue is then cryosectioned, and the microscope slides are processed to fix, stain, and dehydrate the cells. LCM is employed to isolate specific cell types from the slides, identified under the microscope by virtue of their morphology. Detailed protocols are provided for using the currently available ArcturusXT LCM instrument and CapSure(®) LCM Caps, to which the selected cells adhere upon laser capture. To maintain RNA integrity, upon removing a slide from the final processing step, or attaching the first cells on the LCM cap, LCM is completed within 20 min. The cells are then immediately recovered from the LCM cap using a denaturing solution that stabilizes RNA integrity. RNA is prepared using standard methods, modified for working with small samples. To ensure the validity of the microarray data, the quality of the RNA is assessed using the Agilent bioanalyzer. Only RNA that is of sufficient integrity and quantity is used to perform microarray assays. This chapter provides guidance regarding troubleshooting and optimization to obtain high-quality RNA from cells of limited availability, obtained from embryo samples by LCM.
Casey, R; Griffin, T P; Wall, D; Dennedy, M C; Bell, M; O'Shea, P M
2017-01-01
Background The Endocrine Society Clinical Practice Guideline on Phaeochomocytoma and Paraganglioma recommends phlebotomy for plasma-free metanephrines with patients fasted and supine using appropriately defined reference intervals. Studies have shown higher diagnostic sensitivities using these criteria. Further, with seated-sampling protocols, for result interpretation, reference intervals that do not compromise diagnostic sensitivity should be employed. Objective To determine the impact on diagnostic performance and financial cost of using supine reference intervals for result interpretation with our current plasma-free metanephrines fasted/seated-sampling protocol. Methods We conducted a retrospective cohort study of patients who underwent screening for PPGL using plasma-free metanephrines from 2009 to 2014 at Galway University Hospitals. Plasma-free metanephrines were measured using liquid chromatography-tandem mass spectrometry. Supine thresholds for plasma normetanephrine and metanephrine set at 610 pmol/L and 310 pmol/L, respectively, were used. Results A total of 183 patients were evaluated. Mean age of participants was 53.4 (±16.3) years. Five of 183 (2.7%) patients had histologically confirmed PPGL (males, n=4). Using seated reference intervals for plasma-free metanephrines, diagnostic sensitivity and specificity were 100% and 98.9%, respectively, with two false-positive cases. Application of reference intervals established in subjects supine and fasted to this cohort gave diagnostic sensitivity of 100% with specificity of 74.7%. Financial analysis of each pretesting strategy demonstrated cost-equivalence (€147.27/patient). Conclusion Our cost analysis, together with the evidence that fasted/supine-sampling for plasma-free metanephrines, offers more reliable exclusion of PPGL mandates changing our current practice. This study highlights the important advantages of standardized diagnostic protocols for plasma-free metanephrines to ensure the highest diagnostic accuracy for investigation of PPGL.
Laser Capture Microdissection of Embryonic Cells and Preparation of RNA for Microarray Assays
Redmond, Latasha C.; Pang, Christopher J.; Dumur, Catherine; Haar, Jack L.; Lloyd, Joyce A.
2014-01-01
In order to compare the global gene expression profiles of different embryonic cell types, it is first necessary to isolate the specific cells of interest. The purpose of this chapter is to provide a step-by-step protocol to perform laser capture microdissection (LCM) on embryo samples and obtain sufficient amounts of high-quality RNA for microarray hybridizations. Using the LCM/microarray strategy on mouse embryo samples has some challenges, because the cells of interest are available in limited quantities. The first step in the protocol is to obtain embryonic tissue, and immediately cryoprotect and freeze it in a cryomold containing Optimal Cutting Temperature freezing media (Sakura Finetek), using a dry ice–isopentane bath. The tissue is then cryosectioned, and the microscope slides are processed to fix, stain, and dehydrate the cells. LCM is employed to isolate specific cell types from the slides, identified under the microscope by virtue of their morphology. Detailed protocols are provided for using the currently available ArcturusXT LCM instrument and CapSure® LCM Caps, to which the selected cells adhere upon laser capture. To maintain RNA integrity, upon removing a slide from the final processing step, or attaching the first cells on the LCM cap, LCM is completed within 20 min. The cells are then immediately recovered from the LCM cap using a denaturing solution that stabilizes RNA integrity. RNA is prepared using standard methods, modified for working with small samples. To ensure the validity of the microarray data, the quality of the RNA is assessed using the Agilent bioanalyzer. Only RNA that is of sufficient integrity and quantity is used to perform microarray assays. This chapter provides guidance regarding troubleshooting and optimization to obtain high-quality RNA from cells of limited availability, obtained from embryo samples by LCM. PMID:24318813
Farsalinos, Konstantinos E; Yannovits, Nikoletta; Sarri, Theoni; Voudris, Vassilis; Poulas, Konstantinos
2016-06-01
To propose a protocol and evaluate the consistency in nicotine delivery to the aerosol of different types of electronic cigarette (EC) atomizers, as required by regulatory authorities. Three cartomizer and four tank-type atomizer products were tested (three samples per product). The aerosol from three 20-puff sessions from each sample was collected using a smoke machine. Three cartridges from a nicotine inhaler and three tobacco cigarettes were also tested. Analytical laboratory in Greece. Aerosol nicotine levels were measured. Relative standard deviation (RSD, i.e. coefficient of variation) was calculated separately for each cartomizer and replacement atomizer head sample (intrasample RSD) and between different samples (intersample RSD). The percentage difference from the mean, which is used to assess the quality of medicinal nebulizers, was also calculated. The aerosol nicotine levels were 1.01-10.61 mg/20 puffs for ECs, 0.12-0.18 mg/20 puffs for the nicotine inhaler and 1.76-2.20 mg/cigarette for the tobacco cigarettes. The intrasample RSDs were 3.7-12.5% for ECs and 14.3% for the nicotine inhaler and 11.1% for the tobacco cigarettes. The intersample RSDs were higher in cartomizers (range: 6.9-37.8%) compared with tank systems (range: 6.4-9.3%). All tank-type atomizers and one cartomizer were within 75-125% of the mean, as dictated for medicinal nebulizers. Electronic cigarettes that use tank-type atomizers appear to deliver nicotine in more consistent quantities (within the acceptable limits for medicinal nebulizers and similar to the nicotine inhaler) than electronic cigarettes that use cartomizers. The protocol for testing nicotine delivery consistency described in this paper could be used effectively for regulatory purposes. © 2016 Society for the Study of Addiction.
Moulton, Stephen R.; Carter, James L.; Grotheer, Scott A.; Cuffney, Thomas F.; Short, Terry M.
2000-01-01
Qualitative and quantitative methods to process benthic macroinvertebrate (BMI) samples have been developed and tested by the U.S. Geological Survey?s National Water Quality Laboratory Biological Group. The qualitative processing method is based on visually sorting a sample for up to 2 hours. Sorting focuses on attaining organisms that are likely to result in taxonomic identifications to lower taxonomic levels (for example, Genus or Species). Immature and damaged organisms are also sorted when they are likely to result in unique determinations. The sorted sample remnant is scanned briefly by a second person to determine if obvious taxa were missed. The quantitative processing method is based on a fixed-count approach that targets some minimum count, such as 100 or 300 organisms. Organisms are sorted from randomly selected 5.1- by 5.1-centimeter parts of a gridded subsampling frame. The sorted remnant from each sample is resorted by a second individual for at least 10 percent of the original sort time. A large-rare organism search is performed on the unsorted remnant to sort BMI taxa that were not likely represented in the sorted grids. After either qualitatively or quantitatively sorting the sample, BMIs are identified by using one of three different types of taxonomic assessment. The Standard Taxonomic Assessment is comparable to the U.S. Environmental Protection Agency Rapid Bioassessment Protocol III and typically provides Genus- or Species-level taxonomic resolution. The Rapid Taxonomic Assessment is comparable to the U.S. Environmental Protection Agency Rapid Bioassessment Protocol II and provides Familylevel and higher taxonomic resolution. The Custom Taxonomic Assessment provides Species-level resolution whenever possible for groups identified to higher taxonomic levels by using the Standard Taxonomic Assessment. The consistent use of standardized designations and notes facilitates the interpretation of BMI data within and among water-quality studies. Taxonomic identifications are quality assured by verifying all referenced taxa and randomly reviewing 10 percent of the taxonomic identifications performed weekly by Biological Group taxonomists. Taxonomic errors discovered during this review are corrected. BMI data are reviewed for accuracy and completeness prior to release. BMI data are released phylogenetically in spreadsheet format and unprocessed abundances are corrected for laboratory and field subsampling when necessary.
Challenges in standardization of blood pressure measurement at the population level.
Tolonen, Hanna; Koponen, Päivikki; Naska, Androniki; Männistö, Satu; Broda, Grazyna; Palosaari, Tarja; Kuulasmaa, Kari
2015-04-10
Accurate blood pressure measurements are needed in clinical practice, intervention studies and health examination surveys. Blood pressure measurements are sensitive: their accuracy can be affected by measurement environment, behaviour of the subject, measurement procedures, devices used for the measurement and the observer. To minimize errors in blood pressure measurement, a standardized measurement protocol is needed. The European Health Examination Survey (EHES) Pilot project was conducted in 2009-2012. A pilot health examination survey was conducted in 12 countries using a standardized protocol. The measurement protocols used in each survey, training provided for the measurers, measurement data, and observations during site visits were collected and evaluated to assess the level of standardization. The EHES measurement protocol for blood pressure was followed accurately in all 12 pilot surveys. Most of the surveys succeeded in organizing a quiet and comfortable measurement environment, and staff instructed survey participants appropriately before examination visits. In all surveys, blood pressure was measured three times, from the right arm in a sitting posture. The biggest variation was in the device used for the blood pressure measurement. It is possible to reach a high level of standardization for blood pressure measurements across countries and over time. A detailed, standardized measurement protocol, and adequate training and monitoring during the fieldwork and centrally organized quality assessment of the data are needed. The recent EU regulation banning the sale of mercury sphygmomanometer in European Union Member States has set new challenges for the standardization of measurement devices since the validity of oscillometric measurements is device-specific and performance of aneroid devices depends very much on calibration.
Branck, Tobyn A.; Hurley, Matthew J.; Prata, Gianna N.; Crivello, Christina A.
2017-01-01
ABSTRACT Listeria monocytogenes is of great concern in food processing facilities because it persists in biofilms, facilitating biotransfer. Stainless steel is commonly used for food contact surfaces and transport containers. L. monocytogenes biofilms on stainless steel served as a model system for surface sampling, to test the performance of a sonicating swab in comparison with a standard cotton swab. Swab performance and consistency were determined using total viable counts. Stainless steel coupons sampled with both types of swabs were examined using scanning electron microscopy, to visualize biofilms and surface structures (i.e., polishing grooves and scratches). Laser scanning confocal microscopy was used to image and to quantitate the biofilms remaining after sampling with each swab type. The total viable counts were significantly higher (P ≤ 0.05) with the sonicating swab than with the standard swab in each trial. The sonicating swab was more consistent in cell recovery than was the standard swab, with coefficients of variation ranging from 8.9% to 12.3% and from 7.1% to 37.6%, respectively. Scanning electron microscopic imaging showed that biofilms remained in the polished grooves of the coupons sampled with the standard swab but were noticeably absent with the sonicating swab. Percent area measurements of biofilms remaining on the stainless steel coupons showed significantly (P ≤ 0.05) less biofilm remaining when the sonicating swab was used (median, 1.1%), compared with the standard swab (median, 70.4%). The sonicating swab provided greater recovery of cells, with more consistency, than did the standard swab, and it is employs sonication, suction, and scrubbing. IMPORTANCE Inadequate surface sampling can result in foodborne illness outbreaks from biotransfer, since verification of sanitization protocols relies on surface sampling and recovery of microorganisms for detection and enumeration. Swabbing is a standard method for microbiological sampling of surfaces. Although swabbing offers portability and ease of use, there are limitations, such as high user variability and low recovery rates, which can be attributed to many different causes. This study demonstrates some benefits that a sonicating swab has over a standard swab for removal and collection of microbiological samples from a surface, to provide better verification of surface cleanliness and to help decrease the potential for biotransfer of pathogens into foods. PMID:28314729
Branck, Tobyn A; Hurley, Matthew J; Prata, Gianna N; Crivello, Christina A; Marek, Patrick J
2017-06-01
Listeria monocytogenes is of great concern in food processing facilities because it persists in biofilms, facilitating biotransfer. Stainless steel is commonly used for food contact surfaces and transport containers. L. monocytogenes biofilms on stainless steel served as a model system for surface sampling, to test the performance of a sonicating swab in comparison with a standard cotton swab. Swab performance and consistency were determined using total viable counts. Stainless steel coupons sampled with both types of swabs were examined using scanning electron microscopy, to visualize biofilms and surface structures (i.e., polishing grooves and scratches). Laser scanning confocal microscopy was used to image and to quantitate the biofilms remaining after sampling with each swab type. The total viable counts were significantly higher ( P ≤ 0.05) with the sonicating swab than with the standard swab in each trial. The sonicating swab was more consistent in cell recovery than was the standard swab, with coefficients of variation ranging from 8.9% to 12.3% and from 7.1% to 37.6%, respectively. Scanning electron microscopic imaging showed that biofilms remained in the polished grooves of the coupons sampled with the standard swab but were noticeably absent with the sonicating swab. Percent area measurements of biofilms remaining on the stainless steel coupons showed significantly ( P ≤ 0.05) less biofilm remaining when the sonicating swab was used (median, 1.1%), compared with the standard swab (median, 70.4%). The sonicating swab provided greater recovery of cells, with more consistency, than did the standard swab, and it is employs sonication, suction, and scrubbing. IMPORTANCE Inadequate surface sampling can result in foodborne illness outbreaks from biotransfer, since verification of sanitization protocols relies on surface sampling and recovery of microorganisms for detection and enumeration. Swabbing is a standard method for microbiological sampling of surfaces. Although swabbing offers portability and ease of use, there are limitations, such as high user variability and low recovery rates, which can be attributed to many different causes. This study demonstrates some benefits that a sonicating swab has over a standard swab for removal and collection of microbiological samples from a surface, to provide better verification of surface cleanliness and to help decrease the potential for biotransfer of pathogens into foods. Copyright © 2017 American Society for Microbiology.
SUPPLEMENT TO: STANDARD MEASUREMENT PROTOCOLS - FLORIDA RADON RESEARCH PROGRAM
The report supplements earlier published standard protocols for key measurements where data quality is vital to the Florida Radon Research Program. The report adds measurements of small canister radon flux and soil water potential to the section on soil measurements. It adds indo...
Kohlmann, Alexander; Kipps, Thomas J; Rassenti, Laura Z; Downing, James R; Shurtleff, Sheila A; Mills, Ken I; Gilkes, Amanda F; Hofmann, Wolf-Karsten; Basso, Giuseppe; Dell’Orto, Marta Campo; Foà, Robin; Chiaretti, Sabina; De Vos, John; Rauhut, Sonja; Papenhausen, Peter R; Hernández, Jesus M; Lumbreras, Eva; Yeoh, Allen E; Koay, Evelyn S; Li, Rachel; Liu, Wei-min; Williams, Paul M; Wieczorek, Lothar; Haferlach, Torsten
2008-01-01
Gene expression profiling has the potential to enhance current methods for the diagnosis of haematological malignancies. Here, we present data on 204 analyses from an international standardization programme that was conducted in 11 laboratories as a prephase to the Microarray Innovations in LEukemia (MILE) study. Each laboratory prepared two cell line samples, together with three replicate leukaemia patient lysates in two distinct stages: (i) a 5-d course of protocol training, and (ii) independent proficiency testing. Unsupervised, supervised, and r2 correlation analyses demonstrated that microarray analysis can be performed with remarkably high intra-laboratory reproducibility and with comparable quality and reliability. PMID:18573112
NASA Technical Reports Server (NTRS)
Roman, Miguel O.; Nightingale, Joanne; Nickeson, Jaime; Schaepman-Strub, Gabriela
2011-01-01
The goals and objectives of the sub group are: To foster and coordinate quantitative validation of higher level global land products derive d from remotely sensed data, in a traceable way, and to relay results so they are relevant to users. and to increase the quality and effi ciency of global satellite product validation by developing and promo ting international standards and protocols for: (1) Field sampling (2) Scaling techniques (3) Accuracy reporting (4) Data / information exchange also to provide feedback to international structures (GEOSS ) for: (1) Requirements on product accuracy and quality assurance (QA 4EO) (2) Terrestrial ECV measurement standards (3) Definitions for f uture missions
A distance limited method for sampling downed coarse woody debris
Jeffrey H. Gove; Mark J. Ducey; Harry T. Valentine; Michael S. Williams
2012-01-01
A new sampling method for down coarse woody debris is proposed based on limiting the perpendicular distance from individual pieces to a randomly chosen sample point. Two approaches are presented that allow different protocols to be used to determine field measurements; estimators for each protocol are also developed. Both protocols are compared via simulation against...
Kriebel, Anita; Dörr, Claudia; Bandt, Susanne; Rist, Manuela; Roth, Alexander; Hummel, Eva; Kulling, Sabine; Hoffmann, Ingrid; Watzl, Bernhard
2016-01-01
Background The human metabolome is influenced by various intrinsic and extrinsic factors. A precondition to identify such biomarkers is the comprehensive understanding of the composition and variability of the metabolome of healthy humans. Sample handling aspects have an important impact on the composition of the metabolome; therefore, it is crucial for any metabolomics study to standardize protocols on sample collection, preanalytical sample handling, storage, and analytics to keep the nonbiological variability as low as possible. Objective The main objective of the KarMeN study is to analyze the human metabolome in blood and urine by targeted and untargeted metabolite profiling (gas chromatography-mass spectrometry [GC-MS], GC×GC-MS, liquid chromatography-mass spectrometry [LC-MS/MS], and1H nuclear magnetic resonance [NMR] spectroscopy) and to determine the impact of sex, age, body composition, diet, and physical activity on metabolite profiles of healthy women and men. Here, we report the outline of the study protocol with special regard to all aspects that should be considered in studies applying metabolomics. Methods Healthy men and women, aged 18 years or older, were recruited. In addition to a number of anthropometric (height, weight, body mass index, waist circumference, body composition), clinical (blood pressure, electrocardiogram, blood and urine clinical chemistry) and functional parameters (lung function, arterial stiffness), resting metabolic rate, physical activity, fitness, and dietary intake were assessed, and 24-hour urine, fasting spot urine, and plasma samples were collected. Standard operating procedures were established for all steps of the study design. Using different analytical techniques (LC-MS, GC×GC-MS,1H NMR spectroscopy), metabolite profiles of urine and plasma were determined. Data will be analyzed using univariate and multivariate as well as predictive modeling methods. Results The project was funded in 2011 and enrollment was carried out between March 2012 and July 2013. A total of 301 volunteers were eligible to participate in the study. Metabolite profiling of plasma and urine samples has been completed and data analysis is currently underway. Conclusions We established the KarMeN study applying a broad set of clinical and physiological examinations with a high degree of standardization. Our experimental approach of combining scheduled timing of examinations and sampling with the multiplatform approach (GC×GC-MS, GC-MS, LC-MS/MS, and1H NMR spectroscopy) will enable us to differentiate between current and long-term effects of diet and physical activity on metabolite profiles, while enabling us at the same time to consider confounders such as age and sex in the KarMeN study. Trial Registration German Clinical Trials Register DRKS00004890; https://drks-neu.uniklinik-freiburg.de/drks_web/navigate.do? navigationId=trial.HTML&TRIAL_ID=DRKS00004890 (Archived by WebCite at http://www.webcitation.org/6iyM8dMtx) PMID:27421387
Owens, Sean D; Snipes, Joy; Magdesian, K Gary; Christopher, Mary M
2008-03-01
Blood typing before transfusion minimizes the risk of transfusion reactions and prevents immunization of the recipient against incompatible RBC antigens. The major RBC antigens that warrant identification before packed RBC or whole blood transfusions in horses are Ca and Aa. Standard blood-typing protocols are time-consuming (2.5-3.0 hours) and impractical in emergency settings. The purpose of this study was to determine whether equine RBCs could be typed for Ca and Aa antigens using sera from horses with RBC antibodies in a modified rapid (15 minute) blood-typing protocol. Serum was obtained from a horse with anti-Ca antibodies and from another horse with anti-Aa antibodies. The presence of agglutinating antibodies was confirmed with antibody screening. Venous blood samples, collected in citrate-phosphate-dextrose, were obtained from 21 horses of various breeds. Samples were blood typed in the Veterinary Medical Teaching Hospital Hematology Laboratory using standard methodology. Washed RBCs from each of the 21 horses were incubated individually with anti-Ca and anti-Aa sera at dilutions of 1:4, 1:8, and 1:16 for 15 and 30 minutes at room temperature and 37 degrees C. Of the 21 horses, 13 were identified as Aa+/Ca+, four were Aa+/Ca-, two were Aa-/Ca+, and two were Aa-/Ca-. All 17 Aa-positive horses had a positive agglutination reaction at all dilutions of anti-Aa serum, incubation times, and temperatures, while all Aa-negative horses were negative. Each Ca-positive horse had a positive agglutination reaction at all incubation time points and temperatures up to the 1:16 dilution of the anti-Ca serum. All Ca-negative horses were negative at all times, temperatures, and dilutions of anti-Ca serum. Use of the modified protocol on 26 hospitalized horses resulted in accurate typing, based on complete antibody screens. These results support the hypothesis that equine RBCs can be blood typed using a rapid (15 minute) protocol, at room temperature, for the presence of Ca and Aa antigens using equine-derived antisera. This technique may be beneficial for pretransfusion testing of equine patients in an emergency setting.
A Simple XML Producer-Consumer Protocol
NASA Technical Reports Server (NTRS)
Smith, Warren; Gunter, Dan; Quesnel, Darcy; Biegel, Bryan (Technical Monitor)
2001-01-01
There are many different projects from government, academia, and industry that provide services for delivering events in distributed environments. The problem with these event services is that they are not general enough to support all uses and they speak different protocols so that they cannot interoperate. We require such interoperability when we, for example, wish to analyze the performance of an application in a distributed environment. Such an analysis might require performance information from the application, computer systems, networks, and scientific instruments. In this work we propose and evaluate a standard XML-based protocol for the transmission of events in distributed systems. One recent trend in government and academic research is the development and deployment of computational grids. Computational grids are large-scale distributed systems that typically consist of high-performance compute, storage, and networking resources. Examples of such computational grids are the DOE Science Grid, the NASA Information Power Grid (IPG), and the NSF Partnerships for Advanced Computing Infrastructure (PACIs). The major effort to deploy these grids is in the area of developing the software services to allow users to execute applications on these large and diverse sets of resources. These services include security, execution of remote applications, managing remote data, access to information about resources and services, and so on. There are several toolkits for providing these services such as Globus, Legion, and Condor. As part of these efforts to develop computational grids, the Global Grid Forum is working to standardize the protocols and APIs used by various grid services. This standardization will allow interoperability between the client and server software of the toolkits that are providing the grid services. The goal of the Performance Working Group of the Grid Forum is to standardize protocols and representations related to the storage and distribution of performance data. These standard protocols and representations must support tasks such as profiling parallel applications, monitoring the status of computers and networks, and monitoring the performance of services provided by a computational grid. This paper describes a proposed protocol and data representation for the exchange of events in a distributed system. The protocol exchanges messages formatted in XML and it can be layered atop any low-level communication protocol such as TCP or UDP Further, we describe Java and C++ implementations of this protocol and discuss their performance. The next section will provide some further background information. Section 3 describes the main communication patterns of our protocol. Section 4 describes how we represent events and related information using XML. Section 5 describes our protocol and Section 6 discusses the performance of two implementations of the protocol. Finally, an appendix provides the XML Schema definition of our protocol and event information.
Staples, Emily; Ingram, Richard James Michael; Atherton, John Christopher; Robinson, Karen
2013-01-01
Sensitive measurement of multiple cytokine profiles from small mucosal tissue biopsies, for example human gastric biopsies obtained through an endoscope, is technically challenging. Multiplex methods such as Luminex assays offer an attractive solution but standard protocols are not available for tissue samples. We assessed the utility of three commercial Luminex kits (VersaMAP, Bio-Plex and MILLIPLEX) to measure interleukin-17A (IL-17) and interferon-gamma (IFNγ) concentrations in human gastric biopsies and we optimised preparation of mucosal samples for this application. First, we assessed the technical performance, limits of sensitivity and linear dynamic ranges for each kit. Next we spiked human gastric biopsies with recombinant IL-17 and IFNγ at a range of concentrations (1.5 to 1000 pg/mL) and assessed kit accuracy for spiked cytokine recovery and intra-assay precision. We also evaluated the impact of different tissue processing methods and extraction buffers on our results. Finally we assessed recovery of endogenous cytokines in unspiked samples. In terms of sensitivity, all of the kits performed well within the manufacturers' recommended standard curve ranges but the MILLIPLEX kit provided most consistent sensitivity for low cytokine concentrations. In the spiking experiments, the MILLIPLEX kit performed most consistently over the widest range of concentrations. For tissue processing, manual disruption provided significantly improved cytokine recovery over automated methods. Our selected kit and optimised protocol were further validated by measurement of relative cytokine levels in inflamed and uninflamed gastric mucosa using Luminex and real-time polymerase chain reaction. In summary, with proper optimisation Luminex kits (and for IL-17 and IFNγ the MILLIPLEX kit in particular) can be used for the sensitive detection of cytokines in mucosal biopsies. Our results should help other researchers seeking to quantify multiple low concentration cytokines in small tissue samples. PMID:23644159
Surinova, Silvia; Hüttenhain, Ruth; Chang, Ching-Yun; Espona, Lucia; Vitek, Olga; Aebersold, Ruedi
2013-08-01
Targeted proteomics based on selected reaction monitoring (SRM) mass spectrometry is commonly used for accurate and reproducible quantification of protein analytes in complex biological mixtures. Strictly hypothesis-driven, SRM assays quantify each targeted protein by collecting measurements on its peptide fragment ions, called transitions. To achieve sensitive and accurate quantitative results, experimental design and data analysis must consistently account for the variability of the quantified transitions. This consistency is especially important in large experiments, which increasingly require profiling up to hundreds of proteins over hundreds of samples. Here we describe a robust and automated workflow for the analysis of large quantitative SRM data sets that integrates data processing, statistical protein identification and quantification, and dissemination of the results. The integrated workflow combines three software tools: mProphet for peptide identification via probabilistic scoring; SRMstats for protein significance analysis with linear mixed-effect models; and PASSEL, a public repository for storage, retrieval and query of SRM data. The input requirements for the protocol are files with SRM traces in mzXML format, and a file with a list of transitions in a text tab-separated format. The protocol is especially suited for data with heavy isotope-labeled peptide internal standards. We demonstrate the protocol on a clinical data set in which the abundances of 35 biomarker candidates were profiled in 83 blood plasma samples of subjects with ovarian cancer or benign ovarian tumors. The time frame to realize the protocol is 1-2 weeks, depending on the number of replicates used in the experiment.
Bertolde, F Z; Almeida, A-A F; Silva, F A C; Oliveira, T M; Pirovani, C P
2014-07-04
Theobroma cacao is a woody and recalcitrant plant with a very high level of interfering compounds. Standard protocols for protein extraction were proposed for various types of samples, but the presence of interfering compounds in many samples prevented the isolation of proteins suitable for two-dimensional gel electrophoresis (2-DE). An efficient method to extract root proteins for 2-DE was established to overcome these problems. The main features of this protocol are: i) precipitation with trichloroacetic acid/acetone overnight to prepare the acetone dry powder (ADP), ii) several additional steps of sonication in the ADP preparation and extractions with dense sodium dodecyl sulfate and phenol, and iii) adding two stages of phenol extractions. Proteins were extracted from roots using this new protocol (Method B) and a protocol described in the literature for T. cacao leaves and meristems (Method A). Using these methods, we obtained a protein yield of about 0.7 and 2.5 mg per 1.0 g lyophilized root, and a total of 60 and 400 spots could be separated, respectively. Through Method B, it was possible to isolate high-quality protein and a high yield of roots from T. cacao for high-quality 2-DE gels. To demonstrate the quality of the extracted proteins from roots of T. cacao using Method B, several protein spots were cut from the 2-DE gels, analyzed by tandem mass spectrometry, and identified. Method B was further tested on Citrus roots, with a protein yield of about 2.7 mg per 1.0 g lyophilized root and 800 detected spots.
A literature review: polypharmacy protocol for primary care.
Skinner, Mary
2015-01-01
The purpose of this literature review is to critically evaluate published protocols on polypharmacy in adults ages 65 and older that are currently used in primary care settings that may potentially lead to fewer adverse drug events. A review of OVID, CINAHL, EBSCO, Cochrane Library, Medline, and PubMed databases was completed using the following key words: protocol, guideline, geriatrics, elderly, older adult, polypharmacy, and primary care. Inclusion criteria were: articles in medical, nursing, and pharmacology journals with an intervention, protocol, or guideline addressing polypharmacy that lead to fewer adverse drug events. Qualitative and quantitative studies were included. Exclusion criteria were: publications prior to the year 1992. A gap exists in the literature. No standardized protocol for addressing polypharmacy in the primary care setting was found. Mnemonics, algorithms, clinical practice guidelines, and clinical strategies for addressing polypharmacy in a variety of health care settings were found throughout the literature. Several screening instruments for use in primary care to assess potentially inappropriate prescription of medications in the elderly, such as the Beers Criteria and the STOPP screening tool, were identified. However, these screening instruments were not included in a standardized protocol to manage polypharmacy in primary care. Polypharmacy in the elderly is a critical problem that may result in adverse drug events such as falls, hospitalizations, and increased expenditures for both the patient and the health care system. No standardized protocols to address polypharmacy specific to the primary care setting were identified in this review of the literature. Given the growing population of elderly in this country and the high number of medications they consume, it is critical to focus on the utilization of a standardized protocol to address the potential harm of polypharmacy in the primary care setting and evaluate its effects on patient outcomes. Copyright © 2015 Elsevier Inc. All rights reserved.
Laurin, Nancy; Frégeau, Chantal
2012-01-01
The goal of this work was to optimize and validate a fast amplification protocol for the multiplex amplification of the STR loci included in AmpFlSTR(®) Profiler Plus(®) to expedite human DNA identification. By modifying the cycling conditions and by combining the use of a DNA polymerase optimized for high speed PCR (SpeedSTAR™ HS) and a more efficient thermal cycler instrument (Bio-RAD C1000™), we were able to reduce the amplification process from 4h to 26 min. No modification to the commercial AmpFlSTR(®) Profiler Plus(®) primer mix was required. When compared to the current Royal Canadian Mounted Police (RCMP) amplification protocol, no differences with regards to specificity, sensitivity, heterozygote peak height ratios and overall profile balance were noted. Moreover, complete concordance was obtained with profiles previously generated with the standard amplification protocol and minor alleles in mixture samples were reliably typed. An increase in n-4 stutter ratios (2.2% on average for all loci) was observed for profiles amplified with the fast protocol compared to the current procedure. Our results document the robustness of this rapid amplification protocol for STR profiling using the AmpFlSTR(®) Profiler Plus(®) primer set and demonstrate that comparable data can be obtained in substantially less time. This new approach could provide an alternative option to current multiplex STR typing amplification protocols in order to increase throughput or expedite time-sensitive cases. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
A Novel Process Audit for Standardized Perioperative Handoff Protocols.
Pallekonda, Vinay; Scholl, Adam T; McKelvey, George M; Amhaz, Hassan; Essa, Deanna; Narreddy, Spurthy; Tan, Jens; Templonuevo, Mark; Ramirez, Sasha; Petrovic, Michelle A
2017-11-01
A perioperative handoff protocol provides a standardized delivery of communication during a handoff that occurs from the operating room to the postanestheisa care unit or ICU. The protocol's success is dependent, in part, on its continued proper use over time. A novel process audit was developed to help ensure that a perioperative handoff protocol is used accurately and appropriately over time. The Audit Observation Form is used for the Audit Phase of the process audit, while the Audit Averages Form is used for the Data Analysis Phase. Employing minimal resources and using quantitative methods, the process audit provides the necessary means to evaluate the proper execution of any perioperative handoff protocol. Copyright © 2017 The Joint Commission. Published by Elsevier Inc. All rights reserved.
OSI in the NASA science internet: An analysis
NASA Technical Reports Server (NTRS)
Nitzan, Rebecca
1990-01-01
The Open Systems Interconnection (OSI) protocol suite is a result of a world-wide effort to develop international standards for networking. OSI is formalized through the International Organization for Standardization (ISO) and the International Electrotechnical Commission (IEC). The goal of OSI is to provide interoperability between network products without relying on one particular vendor, and to do so on a multinational basis. The National Institute for Standards and Technology (NIST) has developed a Government OSI Profile (GOSIP) that specified a subset of the OSI protocols as a Federal Information Processing Standard (FIPS 146). GOSIP compatibility has been adopted as the direction for all U.S. government networks. OSI is extremely diverse, and therefore adherence to a profile will facilitate interoperability within OSI networks. All major computer vendors have indicated current or future support of GOSIP-compliant OSI protocols in their products. The NASA Science Internet (NSI) is an operational network, serving user requirements under NASA's Office of Space Science and Applications. NSI consists of the Space Physics Analysis Network (SPAN) that uses the DECnet protocols and the NASA Science Network (NSN) that uses TCP/IP protocols. The NSI Project Office is currently working on an OSI integration analysis and strategy. A long-term goal is to integrate SPAN and NSN into one unified network service, using a full OSI protocol suite, which will support the OSSA user community.
T, Sathish Kumar; A, Navaneeth Krishnan; J, Joseph Sahaya Rajan; M, Makesh; K P, Jithendran; S V, Alavandi; K K, Vijayan
2018-05-01
The emerging microsporidian parasite Enterocytozoon hepatopenaei (EHP), the causative agent of hepatopancreatic microsporidiosis, has been widely reported in shrimp-farming countries. EHP infection can be detected by light microscopy observation of spores (1.7 × 1 μm) in stained hepatopancreas (HP) tissue smears, HP tissue sections, and fecal samples. EHP can also be detected by polymerase chain reaction (PCR) targeting the small subunit (SSU) ribosomal RNA (rRNA) gene or the spore wall protein gene (SWP). In this study, a rapid, sensitive, specific, and closed tube visual loop-mediated isothermal amplification (LAMP) protocol combined with FTA cards was developed for the diagnosis of EHP. LAMP primers were designed based on the SSU rRNA gene of EHP. The target sequence of EHP was amplified at constant temperature of 65 °C for 45 min and amplified LAMP products were visually detected in a closed tube system by using SYBR™ green I dye. Detection limit of this LAMP protocol was ten copies. Field and clinical applicability of this assay was evaluated using 162 field samples including 106 HP tissue samples and 56 fecal samples collected from shrimp farms. Out of 162 samples, EHP could be detected in 62 samples (47 HP samples and 15 fecal samples). When compared with SWP-PCR as the gold standard, this EHP LAMP assay had 95.31% sensitivity, 98.98% specificity, and a kappa value of 0.948. This simple, closed tube, clinically evaluated visual LAMP assay has great potential for diagnosing EHP at the farm level, particularly under low-resource circumstances.
Chapter A7. Section 7.1. Fecal Indicator Bacteria
Myers, Donna N.; Sylvester, Marc A.
1997-01-01
Fecal indicator bacteria are used to assess the microbiological quality of water because, although not typically disease causing, they are correlated with the presence of several waterborne disease-causing organisms. The concentration of indicator bacteria is a measure of water safety for body-contact recreation or for consumption. This report provides information on the equipment, sampling protocols, and identification, enumeration, and calculation procedures that are in standard use by U.S. Geological Survey (USGS) personnel for the collection of data on fecal indicator bacteria.
Binding Assays Using Recombinant SH2 Domains: Far-Western, Pull-Down, and Fluorescence Polarization.
Machida, Kazuya; Liu, Bernard
2017-01-01
Recognition of phosphotyrosine-containing sequences by SH2 domains confers specificity in tyrosine kinase pathways. By assessing interactions between isolated SH2 domains and their binding proteins, it is possible to gain insight into otherwise inaccessible complex cellular systems. Far-Western, pull-down, and fluorescence polarization (FP) have been frequently used for characterization of phosphotyrosine signaling. Here, we outline standard protocols for these established assays using recombinant SH2 domain, emphasizing the importance of appropriate sample preparation and assay controls.
Fell, Shari; Bröckl, Stephanie; Büttner, Mathias; Rettinger, Anna; Zimmermann, Pia; Straubinger, Reinhard K
2016-09-15
Bovine tuberculosis (bTB), which is caused by Mycobacterium bovis and M. caprae, is a notifiable animal disease in Germany. Diagnostic procedure is based on a prescribed protocol that is published in the framework of German bTB legislation. In this protocol small sample volumes are used for DNA extraction followed by real-time PCR analyses. As mycobacteria tend to concentrate in granuloma and the infected tissue in early stages of infection does not necessarily show any visible lesions, it is likely that DNA extraction from only small tissue samples (20-40 mg) of a randomly chosen spot from the organ and following PCR testing may result in false negative results. In this study two DNA extraction methods were developed to process larger sample volumes to increase the detection sensitivity of mycobacterial DNA in animal tissue. The first extraction method is based on magnetic capture, in which specific capture oligonucleotides were utilized. These nucleotides are linked to magnetic particles and capture Mycobacterium-tuberculosis-complex (MTC) DNA released from 10 to 15 g of tissue material. In a second approach remaining sediments from the magnetic capture protocol were further processed with a less complex extraction protocol that can be used in daily routine diagnostics. A total number of 100 tissue samples from 34 cattle (n = 74) and 18 red deer (n = 26) were analyzed with the developed protocols and results were compared to the prescribed protocol. All three extraction methods yield reliable results by the real-time PCR analysis. The use of larger sample volume led to a sensitivity increase of DNA detection which was shown by the decrease of Ct-values. Furthermore five samples which were tested negative or questionable by the official extraction protocol were detected positive by real time PCR when the alternative extraction methods were used. By calculating the kappa index, the three extraction protocols resulted in a moderate (0.52; protocol 1 vs 3) to almost perfect agreement (1.00; red deer sample testing with all protocols). Both new methods yielded increased detection rates for MTC DNA detection in large sample volumes and consequently improve the official diagnostic protocol.
Kuttner, Samuel; Bujila, Robert; Kortesniemi, Mika; Andersson, Henrik; Kull, Love; Østerås, Bjørn Helge; Thygesen, Jesper; Tarp, Ivanka Sojat
2013-03-01
Quality assurance (QA) of computed tomography (CT) systems is one of the routine tasks for medical physicists in the Nordic countries. However, standardized QA protocols do not yet exist and the QA methods, as well as the applied tolerance levels, vary in scope and extent at different hospitals. To propose a standardized protocol for acceptance and constancy testing of CT scanners in the Nordic Region. Following a Nordic Association for Clinical Physics (NACP) initiative, a group of medical physicists, with representatives from four Nordic countries, was formed. Based on international literature and practical experience within the group, a comprehensive standardized test protocol was developed. The proposed protocol includes tests related to the mechanical functionality, X-ray tube, detector, and image quality for CT scanners. For each test, recommendations regarding the purpose, equipment needed, an outline of the test method, the measured parameter, tolerance levels, and the testing frequency are stated. In addition, a number of optional tests are briefly discussed that may provide further information about the CT system. Based on international references and medical physicists' practical experiences, a comprehensive QA protocol for CT systems is proposed, including both acceptance and constancy tests. The protocol may serve as a reference for medical physicists in the Nordic countries.
Student Performances in Various Learning Protocols
ERIC Educational Resources Information Center
Gregorius, Roberto
2011-01-01
A comparison was made between students' overall performance, as measured by overall grade, in different teaching and learning protocols: (1) traditional textbook and lecture along with standard examinations; (2) lectures with online augmentation and PowerPoint lecture notes along with standard examinations; (3) similar to "(2)" but with…
Current federal regulations required monitoring for fecal coliforms or Salmonella in biosolids destined for land application. Methods used for analysis of fecal coliforms and Salmonella were reviewed and a standard protocol was developed. The protocols were then...
Current federal regulations require monitoring for fecal coliforms or Salmonella in biosolids destined for land application. Methods used for analysis of fecal coliforms and Salmonella were reviewed and a standard protocol was developed. The protocols were then evaluated by testi...
Bourier, Felix; Reents, Tilko; Ammar-Busch, Sonia; Buiatti, Alessandra; Kottmaier, Marc; Semmler, Verena; Telishevska, Marta; Brkic, Amir; Grebmer, Christian; Lennerz, Carsten; Kolb, Christof; Hessling, Gabriele; Deisenhofer, Isabel
2016-09-01
This study presents and evaluates the impact of a new lowest-dose fluoroscopy protocol (Siemens AG), especially designed for electrophysiology (EP) procedures, on X-ray dose levels. From October 2014 to March 2015, 140 patients underwent an EP study on an Artis zee angiography system. The standard low-dose protocol was operated at 23 nGy (fluoroscopy) and at 120 nGy (cine-loop), the new lowest-dose protocol was operated at 8 nGy (fluoroscopy) and at 36 nGy (cine-loop). Procedural data, X-ray times, and doses were analysed in 100 complex left atrial and in 40 standard EP procedures. The resulting dose-area products were 877.9 ± 624.7 µGym² (n = 50 complex procedures, standard low dose), 199 ± 159.6 µGym² (n = 50 complex procedures, lowest dose), 387.7 ± 36.0 µGym² (n = 20 standard procedures, standard low dose), and 90.7 ± 62.3 µGym² (n = 20 standard procedures, lowest dose), P < 0.01. In the low-dose and lowest-dose groups, procedure times were 132.6 ± 35.7 vs. 126.7 ± 34.7 min (P = 0.40, complex procedures) and 72.3 ± 20.9 vs. 85.2 ± 44.1 min (P = 0.24, standard procedures), radiofrequency (RF) times were 53.8 ± 26.1 vs. 50.4 ± 29.4 min (P = 0.54, complex procedures) and 10.1 ± 9.9 vs. 12.2 ± 14.7 min (P = 0.60, standard procedures). One complication occurred in the standard low-dose and lowest-dose groups (P = 1.0). The new lowest-dose imaging protocol reduces X-ray dose levels by 77% compared with the currently available standard low-dose protocol. From an operator standpoint, lowest X-ray dose levels create a different, reduced image quality. The new image quality did not significantly affect procedure or RF times and did not result in higher complication rates. Regarding radiological protection, operating at lowest-dose settings should become standard in EP procedures. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.
Sonoclot evaluation of whole blood coagulation in healthy adult dogs.
Babski, Danielle M; Brainard, Benjamin M; Krimer, Paula M; Ralph, Alan G; Pittman, Jennifer R; Koenig, Amie
2012-12-01
To establish a standard protocol for analysis of canine whole blood and generate reference intervals for healthy dogs using the Sonoclot analyzer, and to compare Sonoclot values to standard and viscoelastic coagulation tests. Prospective study. Veterinary University research facility and teaching hospital. Twelve healthy random source dogs and 52 healthy dogs from the general veterinary school population. Blood sampling for viscoelastic coagulation testing. Blood was collected from 12 healthy adult dogs by jugular venipuncture. After a rest period at room temperature of 30, 60, or 120 minutes, 340 μL of citrated blood was added to 20 μL of 0.2 M CaCl(2) in 1 of 2 cuvette types warmed to 37° C. Cuvettes contained a magnetic stir-bar with glass beads (gbACT+) or only a magnetic stir-bar (nonACT). Reference interval samples were collected from 52 healthy adult dogs and analyzed in duplicate. The ACT, CR, and PF were not affected by duration of rest period for either cuvette type. ACT variability was decreased when using gbACT+ cuvettes (P < 0.05). In normal dogs reference intervals (mean ± 2 SD) using gbACT+ cuvettes were: ACT 56.0-154.0 seconds, CR 14.85-46.0, and PF 2.1-4.05. ACT correlated to TEG R-time, K-time, and angle, while CR correlated with all TEG parameters. Fibrinogen correlated with ACT, CR, and PF. Sonoclot did not correlate with other common coagulation tests. Sonoclot provides viscoelastic evaluation of canine whole blood coagulation and correlated to several TEG parameters and fibrinogen. A standard protocol and reference intervals were established. © Veterinary Emergency and Critical Care Society 2012.
Gamma radiation-induced thermoluminescence emission of minerals adhered to Mexican sesame seeds
NASA Astrophysics Data System (ADS)
Rodríguez-Lazcano, Y.; Correcher, V.; Garcia-Guinea, J.; Cruz-Zaragoza, E.
2013-02-01
The thermoluminescence (TL) emission of minerals isolated from Mexican sesame seeds appear as a good tool to discern between irradiated and non-irradiated samples. According to the X-ray diffraction (XRD) and environmental scanning electron microscope (ESEM) data, the adhered dust in both samples is mainly composed of different amounts of quartz and feldspars. These mineral phases exhibit (i) enough sensitivity to ionizing radiation inducing good TL intensity, (ii) high stability of the TL signal during the storage of the material, i.e. low fading, and (iii) are thermally and chemically stable. Blind tests were performed under laboratory conditions, but simulating industrial preservation processes, allow us to distinguish between 1 kGy gamma-irradiated and non-irradiated samples even 15 months after irradiation processing followed the EN 1788 European Standard protocol in sesame samples.
NASA Astrophysics Data System (ADS)
Weltzin, J. F.; USA National Phenology Network National Coordinating Office
2011-12-01
The USA National Phenology Network (USA-NPN; www.usanpn.org), established in 2007, is a national science and monitoring initiative focused on phenology as a tool to understand how plants, animals and landscapes respond to climatic variability and change. Core functions of the National Coordinating Office (NCO) of USA-NPN are to provide a national information management system including databases, develop and implement internationally standardized phenology monitoring protocols, create partnerships with a variety of organizations including field stations for implementation, facilitate research and the development of decision support tools, and promote education and outreach activities related to phenology and climate change. This presentation will describe programs, tools and materials developed by USA-NPN to facilitate science, management and education related to phenology of plants, animals and landscapes within protected areas at local, regional and national scales. Particular emphasis will be placed on the on-line integrated animal and plant monitoring program, Nature's Notebook, which provides standardized protocols for phenological status monitoring and data management for over 500 animal and plant species. The monitoring system facilitates collection of sampling intensity, absence data, considerable metadata (from site to observation). We recently added functionality for recording estimates of animal abundance and plant canopy development. Real-time raw data for plants (from 2009 to present) and animals (from 2010 to present), including FGDC-compliant metadata and documented methodology, are now available for download from the website. A new data exploration tool premiered in spring 2010 allows sophisticated graphical visualization of integrated phenological and meteorological data. The network seeks to develop partnerships with other organizations interested in (1) implementing vetted, standardized protocols for phenological or ecological monitoring, and (2) using phenology data and information for a variety of modeling applications.
Percy, Andrew J; Yang, Juncong; Chambers, Andrew G; Mohammed, Yassene; Miliotis, Tasso; Borchers, Christoph H
2016-01-01
Quantitative mass spectrometry (MS)-based approaches are emerging as a core technology for addressing health-related queries in systems biology and in the biomedical and clinical fields. In several 'omics disciplines (proteomics included), an approach centered on selected or multiple reaction monitoring (SRM or MRM)-MS with stable isotope-labeled standards (SIS), at the protein or peptide level, has emerged as the most precise technique for quantifying and screening putative analytes in biological samples. To enable the widespread use of MRM-based protein quantitation for disease biomarker assessment studies and its ultimate acceptance for clinical analysis, the technique must be standardized to facilitate precise and accurate protein quantitation. To that end, we have developed a number of kits for assessing method/platform performance, as well as for screening proposed candidate protein biomarkers in various human biofluids. Collectively, these kits utilize a bottom-up LC-MS methodology with SIS peptides as internal standards and quantify proteins using regression analysis of standard curves. This chapter details the methodology used to quantify 192 plasma proteins of high-to-moderate abundance (covers a 6 order of magnitude range from 31 mg/mL for albumin to 18 ng/mL for peroxidredoxin-2), and a 21-protein subset thereof. We also describe the application of this method to patient samples for biomarker discovery and verification studies. Additionally, we introduce our recently developed Qualis-SIS software, which is used to expedite the analysis and assessment of protein quantitation data in control and patient samples.
NASA Technical Reports Server (NTRS)
Ivancic, William D.; Glover, Daniel R.; vonDeak, Thomas C.; Bhasin, Kul B.
1998-01-01
The realization of the full potential of the National Information Infrastructure (NH) and Global Information Infrastructure (GII) requires seamless interoperability of emerging satellite networks with terrestrial networks. This requires a cooperative effort between industry, academia and government agencies to develop and advocate new, satellite-friendly communication protocols and modifications to existing communication protocol standards. These groups have recently come together to actively participating in a number of standards making bodies including: the Internet Engineering Task Force (IETF), the Asynchronous Transfer Mode (ATM) Forum, the International Telecommunication Union (ITU) and the Telecommunication Industry Association MA) to ensure that issues regarding efficient use of these protocols over satellite links are not overlooked. This paper will summarize the progress made toward standards development to achieve seamless integration and accelerate the deployment of multimedia applications.
Normalization of mass cytometry data with bead standards
Finck, Rachel; Simonds, Erin F.; Jager, Astraea; Krishnaswamy, Smita; Sachs, Karen; Fantl, Wendy; Pe’er, Dana; Nolan, Garry P.; Bendall, Sean C.
2013-01-01
Mass cytometry uses atomic mass spectrometry combined with isotopically pure reporter elements to currently measure as many as 40 parameters per single cell. As with any quantitative technology, there is a fundamental need for quality assurance and normalization protocols. In the case of mass cytometry, the signal variation over time due to changes in instrument performance combined with intervals between scheduled maintenance must be accounted for and then normalized. Here, samples were mixed with polystyrene beads embedded with metal lanthanides, allowing monitoring of mass cytometry instrument performance over multiple days of data acquisition. The protocol described here includes simultaneous measurements of beads and cells on the mass cytometer, subsequent extraction of the bead-based signature, and the application of an algorithm enabling correction of both short- and long-term signal fluctuations. The variation in the intensity of the beads that remains after normalization may also be used to determine data quality. Application of the algorithm to a one-month longitudinal analysis of a human peripheral blood sample reduced the range of median signal fluctuation from 4.9-fold to 1.3-fold. PMID:23512433
A communal catalogue reveals Earth’s multiscale microbial diversity
Thompson, Luke R.; Sanders, Jon G.; McDonald, Daniel; ...
2017-11-01
Our growing awareness of the importance and diversity of the microbial world contrasts starkly with our limited understanding of its fundamental structure. Despite remarkable advances in DNA sequence generation, a lack of standardized protocols and common analytical framework impede useful comparison between studies, hindering development of global inferences about microbial life on Earth. Here, we show that with coordinated protocols, exact microbial 16S rRNA gene sequences can be followed across scores of individual studies, revealing patterns of diversity, community structure, and life history strategy at a planetary scale. Using 27,751 crowdsourced environmental samples comprising more than 2.2 billion reads, wemore » find sharp divides between host-associated and free-living communities. We show that the distribution of taxonomic and sequence diversity follows consistent trends across samples types and along gradients of environmental parameters, highlighting some of the global evolutionary patterns and ecological principles that underpin Earth’s microbiome. Here, this dataset provides the most complete environmental survey of our microbial world to date, and serves as a growing reference to provide immediate global context to future microbial surveys.« less
A Method for Identification and Analysis of Non-Overlapping Myeloid Immunophenotypes in Humans
Gustafson, Michael P.; Lin, Yi; Maas, Mary L.; Van Keulen, Virginia P.; Johnston, Patrick B.; Peikert, Tobias; Gastineau, Dennis A.; Dietz, Allan B.
2015-01-01
The development of flow cytometric biomarkers in human studies and clinical trials has been slowed by inconsistent sample processing, use of cell surface markers, and reporting of immunophenotypes. Additionally, the function(s) of distinct cell types as biomarkers cannot be accurately defined without the proper identification of homogeneous populations. As such, we developed a method for the identification and analysis of human leukocyte populations by the use of eight 10-color flow cytometric protocols in combination with novel software analyses. This method utilizes un-manipulated biological sample preparation that allows for the direct quantitation of leukocytes and non-overlapping immunophenotypes. We specifically designed myeloid protocols that enable us to define distinct phenotypes that include mature monocytes, granulocytes, circulating dendritic cells, immature myeloid cells, and myeloid derived suppressor cells (MDSCs). We also identified CD123 as an additional distinguishing marker for the phenotypic characterization of immature LIN-CD33+HLA-DR- MDSCs. Our approach permits the comprehensive analysis of all peripheral blood leukocytes and yields data that is highly amenable for standardization across inter-laboratory comparisons for human studies. PMID:25799053
A communal catalogue reveals Earth’s multiscale microbial diversity
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thompson, Luke R.; Sanders, Jon G.; McDonald, Daniel
Our growing awareness of the importance and diversity of the microbial world contrasts starkly with our limited understanding of its fundamental structure. Despite remarkable advances in DNA sequence generation, a lack of standardized protocols and common analytical framework impede useful comparison between studies, hindering development of global inferences about microbial life on Earth. Here, we show that with coordinated protocols, exact microbial 16S rRNA gene sequences can be followed across scores of individual studies, revealing patterns of diversity, community structure, and life history strategy at a planetary scale. Using 27,751 crowdsourced environmental samples comprising more than 2.2 billion reads, wemore » find sharp divides between host-associated and free-living communities. We show that the distribution of taxonomic and sequence diversity follows consistent trends across samples types and along gradients of environmental parameters, highlighting some of the global evolutionary patterns and ecological principles that underpin Earth’s microbiome. Here, this dataset provides the most complete environmental survey of our microbial world to date, and serves as a growing reference to provide immediate global context to future microbial surveys.« less
Coêlho, Diego F; Saturnino, Thais Peron; Fernandes, Fernanda Freitas; Mazzola, Priscila Gava; Silveira, Edgar; Tambourgi, Elias Basile
2016-01-01
Given the importance of protease's worldwide market, the determination of optimum conditions and the development of a standard protocol are critical during selection of a reliable method to determine its bioactivity. This paper uses quality control theory to validate a modified version of a method proposed by Charney and Tomarelli in 1947. The results obtained showed that using azocasein substrate bromelain had its optimum at 45°C and pH 9 (Glycine-NaOH 100 mM). We also quantified the limit of detection (LoD) and limit of quantification (LoQ) in the above-mentioned optimum (0.072 and 0.494 mg·mL(-1) of azocasein, resp.) and a calibration curve that correlates optical density with the amount of substrate digested. In all analysed samples, we observed a significant decrease in response after storage (around 17%), which suggests its use must be immediately after preparation. Thus, the protocol presented in this paper offers a significant improvement, given that subjective definitions are commonly used in the literature and this simple mathematical approach makes it clear and concise.
Mazzola, Priscila Gava
2016-01-01
Given the importance of protease's worldwide market, the determination of optimum conditions and the development of a standard protocol are critical during selection of a reliable method to determine its bioactivity. This paper uses quality control theory to validate a modified version of a method proposed by Charney and Tomarelli in 1947. The results obtained showed that using azocasein substrate bromelain had its optimum at 45°C and pH 9 (Glycine-NaOH 100 mM). We also quantified the limit of detection (LoD) and limit of quantification (LoQ) in the above-mentioned optimum (0.072 and 0.494 mg·mL−1 of azocasein, resp.) and a calibration curve that correlates optical density with the amount of substrate digested. In all analysed samples, we observed a significant decrease in response after storage (around 17%), which suggests its use must be immediately after preparation. Thus, the protocol presented in this paper offers a significant improvement, given that subjective definitions are commonly used in the literature and this simple mathematical approach makes it clear and concise. PMID:26925415
ERIC Educational Resources Information Center
Benner, Gregory J.; Nelson, J. Ron; Sanders, Elizabeth A.; Ralston, Nicole C.
2012-01-01
This article examined the efficacy of a primary-level, standard-protocol behavior intervention for students with externalizing behavioral disorders. Elementary schools were randomly assigned to treatment (behavior intervention) or control (business as usual) conditions, and K-3 students were screened for externalizing behavior risk status. The…
DELAMINATION AND XRF ANALYSIS OF NIST LEAD IN PAINT FILM STANDARDS
The objectives of this protocol were to remove the laminate coating from lead paint film standards acquired from NIST by means of surface heating. The average XRF value did not change after removal of the polymer coating suggesting that this protocol is satisfactory for renderin...
NASA STI Program Coordinating Council Twelfth Meeting: Standards
NASA Technical Reports Server (NTRS)
1994-01-01
The theme of this NASA Scientific and Technical Information Program Coordinating Council Meeting was standards and their formation and application. Topics covered included scientific and technical information architecture, the Open Systems Interconnection Transmission Control Protocol/Internet Protocol, Machine-Readable Cataloging (MARC) open system environment procurement, and the Government Information Locator Service.
A standard protocol for describing individual-based and agent-based models
Grimm, Volker; Berger, Uta; Bastiansen, Finn; Eliassen, Sigrunn; Ginot, Vincent; Giske, Jarl; Goss-Custard, John; Grand, Tamara; Heinz, Simone K.; Huse, Geir; Huth, Andreas; Jepsen, Jane U.; Jorgensen, Christian; Mooij, Wolf M.; Muller, Birgit; Pe'er, Guy; Piou, Cyril; Railsback, Steven F.; Robbins, Andrew M.; Robbins, Martha M.; Rossmanith, Eva; Ruger, Nadja; Strand, Espen; Souissi, Sami; Stillman, Richard A.; Vabo, Rune; Visser, Ute; DeAngelis, Donald L.
2006-01-01
Simulation models that describe autonomous individual organisms (individual based models, IBM) or agents (agent-based models, ABM) have become a widely used tool, not only in ecology, but also in many other disciplines dealing with complex systems made up of autonomous entities. However, there is no standard protocol for describing such simulation models, which can make them difficult to understand and to duplicate. This paper presents a proposed standard protocol, ODD, for describing IBMs and ABMs, developed and tested by 28 modellers who cover a wide range of fields within ecology. This protocol consists of three blocks (Overview, Design concepts, and Details), which are subdivided into seven elements: Purpose, State variables and scales, Process overview and scheduling, Design concepts, Initialization, Input, and Submodels. We explain which aspects of a model should be described in each element, and we present an example to illustrate the protocol in use. In addition, 19 examples are available in an Online Appendix. We consider ODD as a first step for establishing a more detailed common format of the description of IBMs and ABMs. Once initiated, the protocol will hopefully evolve as it becomes used by a sufficiently large proportion of modellers.
The Space Communications Protocol Standards Program
NASA Technical Reports Server (NTRS)
Jeffries, Alan; Hooke, Adrian J.
1994-01-01
In the fall of 1992 NASA and the Department of Defense chartered a technical team to explore the possibility of developing a common set of space data communications standards for potential dual-use across the U.S. national space mission support infrastructure. The team focused on the data communications needs of those activities associated with on-lined control of civil and military aircraft. A two-pronged approach was adopted: a top-down survey of representative civil and military space data communications requirements was conducted; and a bottom-up analysis of available standard data communications protocols was performed. A striking intersection of civil and military space mission requirements emerged, and an equally striking consensus on the approach towards joint civil and military space protocol development was reached. The team concluded that wide segments of the U.S. civil and military space communities have common needs for: (1) an efficient file transfer protocol; (2) various flavors of underlying data transport service; (3) an optional data protection mechanism to assure end-to-end security of message exchange; and (4) an efficient internetworking protocol. These recommendations led to initiating a program to develop a suite of protocols based on these findings. This paper describes the current status of this program.
A practical way to estimate retail tobacco sales violation rates more accurately.
Levinson, Arnold H; Patnaik, Jennifer L
2013-11-01
U.S. states annually estimate retailer propensity to sell adolescents cigarettes, which is a violation of law, by staging a single purchase attempt among a random sample of tobacco businesses. The accuracy of single-visit estimates is unknown. We examined this question using a novel test-retest protocol. Supervised minors attempted to purchase cigarettes at all retail tobacco businesses located in 3 Colorado counties. The attempts observed federal standards: Minors were aged 15-16 years, were nonsmokers, and were free of visible tattoos and piercings, and were allowed to enter stores alone or in pairs to purchase a small item while asking for cigarettes and to show or not show genuine identification (ID, e.g., driver's license). Unlike federal standards, stores received a second purchase attempt within a few days unless minors were firmly told not to return. Separate violation rates were calculated for first visits, second visits, and either visit. Eleven minors attempted to purchase cigarettes 1,079 times from 671 retail businesses. One sixth of first visits (16.8%) resulted in a violation; the rate was similar for second visits (15.7%). Considering either visit, 25.3% of businesses failed the test. Factors predictive of violation were whether clerks asked for ID, whether the clerks closely examined IDs, and whether minors included snacks or soft drinks in cigarette purchase attempts. A test-retest protocol for estimating underage cigarette sales detected half again as many businesses in violation as the federally approved one-test protocol. Federal policy makers should consider using the test-retest protocol to increase accuracy and awareness of widespread adolescent access to cigarettes through retail businesses.
NASA Astrophysics Data System (ADS)
Guillevic, P. C.; Nickeson, J. E.; Roman, M. O.; camacho De Coca, F.; Wang, Z.; Schaepman-Strub, G.
2016-12-01
The Global Climate Observing System (GCOS) has specified the need to systematically produce and validate Essential Climate Variables (ECVs). The Committee on Earth Observation Satellites (CEOS) Working Group on Calibration and Validation (WGCV) and in particular its subgroup on Land Product Validation (LPV) is playing a key coordination role leveraging the international expertise required to address actions related to the validation of global land ECVs. The primary objective of the LPV subgroup is to set standards for validation methods and reporting in order to provide traceable and reliable uncertainty estimates for scientists and stakeholders. The Subgroup is comprised of 9 focus areas that encompass 10 land surface variables. The activities of each focus area are coordinated by two international co-leads and currently include leaf area index (LAI) and fraction of absorbed photosynthetically active radiation (FAPAR), vegetation phenology, surface albedo, fire disturbance, snow cover, land cover and land use change, soil moisture, land surface temperature (LST) and emissivity. Recent additions to the focus areas include vegetation indices and biomass. The development of best practice validation protocols is a core activity of CEOS LPV with the objective to standardize the evaluation of land surface products. LPV has identified four validation levels corresponding to increasing spatial and temporal representativeness of reference samples used to perform validation. Best practice validation protocols (1) provide the definition of variables, ancillary information and uncertainty metrics, (2) describe available data sources and methods to establish reference validation datasets with SI traceability, and (3) describe evaluation methods and reporting. An overview on validation best practice components will be presented based on the LAI and LST protocol efforts to date.
Hooper, Lisa M.; Weinfurt, Kevin P.; Cooper, Lisa A.; Mensh, Julie; Harless, William; Kuhajda, Melissa C.; Epstein, Steven A.
2009-01-01
Background Some primary care physicians provide less than optimal care for depression (Kessler et al., Journal of the American Medical Association 291, 2581–90, 2004). However, the literature is not unanimous on the best method to use in order to investigate this variation in care. To capture variations in physician behaviour and decision making in primary care settings, 32 interactive CD-ROM vignettes were constructed and tested. Aim and method The primary aim of this methods-focused paper was to review the extent to which our study method – an interactive CD-ROM patient vignette methodology – was effective in capturing variation in physician behaviour. Specifically, we examined the following questions: (a) Did the interactive CD-ROM technology work? (b) Did we create believable virtual patients? (c) Did the research protocol enable interviews (data collection) to be completed as planned? (d) To what extent was the targeted study sample size achieved? and (e) Did the study interview protocol generate valid and reliable quantitative data and rich, credible qualitative data? Findings Among a sample of 404 randomly selected primary care physicians, our voice-activated interactive methodology appeared to be effective. Specifically, our methodology – combining interactive virtual patient vignette technology, experimental design, and expansive open-ended interview protocol – generated valid explanations for variations in primary care physician practice patterns related to depression care. PMID:20463864
Soil pH Mapping with an On-The-Go Sensor
Schirrmann, Michael; Gebbers, Robin; Kramer, Eckart; Seidel, Jan
2011-01-01
Soil pH is a key parameter for crop productivity, therefore, its spatial variation should be adequately addressed to improve precision management decisions. Recently, the Veris pH Manager™, a sensor for high-resolution mapping of soil pH at the field scale, has been made commercially available in the US. While driving over the field, soil pH is measured on-the-go directly within the soil by ion selective antimony electrodes. The aim of this study was to evaluate the Veris pH Manager™ under farming conditions in Germany. Sensor readings were compared with data obtained by standard protocols of soil pH assessment. Experiments took place under different scenarios: (a) controlled tests in the lab, (b) semicontrolled test on transects in a stop-and-go mode, and (c) tests under practical conditions in the field with the sensor working in its typical on-the-go mode. Accuracy issues, problems, options, and potential benefits of the Veris pH Manager™ were addressed. The tests demonstrated a high degree of linearity between standard laboratory values and sensor readings. Under practical conditions in the field (scenario c), the measure of fit (r2) for the regression between the on-the-go measurements and the reference data was 0.71, 0.63, and 0.84, respectively. Field-specific calibration was necessary to reduce systematic errors. Accuracy of the on-the-go maps was considerably higher compared with the pH maps obtained by following the standard protocols, and the error in calculating lime requirements was reduced by about one half. However, the system showed some weaknesses due to blockage by residual straw and weed roots. If these problems were solved, the on-the-go sensor investigated here could be an efficient alternative to standard sampling protocols as a basis for liming in Germany. PMID:22346591
Soil pH mapping with an on-the-go sensor.
Schirrmann, Michael; Gebbers, Robin; Kramer, Eckart; Seidel, Jan
2011-01-01
Soil pH is a key parameter for crop productivity, therefore, its spatial variation should be adequately addressed to improve precision management decisions. Recently, the Veris pH Manager™, a sensor for high-resolution mapping of soil pH at the field scale, has been made commercially available in the US. While driving over the field, soil pH is measured on-the-go directly within the soil by ion selective antimony electrodes. The aim of this study was to evaluate the Veris pH Manager™ under farming conditions in Germany. Sensor readings were compared with data obtained by standard protocols of soil pH assessment. Experiments took place under different scenarios: (a) controlled tests in the lab, (b) semicontrolled test on transects in a stop-and-go mode, and (c) tests under practical conditions in the field with the sensor working in its typical on-the-go mode. Accuracy issues, problems, options, and potential benefits of the Veris pH Manager™ were addressed. The tests demonstrated a high degree of linearity between standard laboratory values and sensor readings. Under practical conditions in the field (scenario c), the measure of fit (r(2)) for the regression between the on-the-go measurements and the reference data was 0.71, 0.63, and 0.84, respectively. Field-specific calibration was necessary to reduce systematic errors. Accuracy of the on-the-go maps was considerably higher compared with the pH maps obtained by following the standard protocols, and the error in calculating lime requirements was reduced by about one half. However, the system showed some weaknesses due to blockage by residual straw and weed roots. If these problems were solved, the on-the-go sensor investigated here could be an efficient alternative to standard sampling protocols as a basis for liming in Germany.
A virtual experimenter to increase standardization for the investigation of placebo effects.
Horing, Bjoern; Newsome, Nathan D; Enck, Paul; Babu, Sabarish V; Muth, Eric R
2016-07-18
Placebo effects are mediated by expectancy, which is highly influenced by psychosocial factors of a treatment context. These factors are difficult to standardize. Furthermore, dedicated placebo research often necessitates single-blind deceptive designs where biases are easily introduced. We propose a study protocol employing a virtual experimenter - a computer program designed to deliver treatment and instructions - for the purpose of standardization and reduction of biases when investigating placebo effects. To evaluate the virtual experimenter's efficacy in inducing placebo effects via expectancy manipulation, we suggest a partially blinded, deceptive design with a baseline/retest pain protocol (hand immersions in hot water bath). Between immersions, participants will receive an (actually inert) medication. Instructions pertaining to the medication will be delivered by one of three metaphors: The virtual experimenter, a human experimenter, and an audio/text presentation (predictor "Metaphor"). The second predictor includes falsely informing participants that the medication is an effective pain killer, or correctly informing them that it is, in fact, inert (predictor "Instruction"). Analysis will be performed with hierarchical linear modelling, with a sample size of N = 50. Results from two pilot studies are presented that indicate the viability of the pain protocol (N = 33), and of the virtual experimenter software and placebo manipulation (N = 48). It will be challenging to establish full comparability between all metaphors used for instruction delivery, and to account for participant differences in acceptance of their virtual interaction partner. Once established, the presence of placebo effects would suggest that the virtual experimenter exhibits sufficient cues to be perceived as a social agent. He could consequently provide a convenient platform to investigate effects of experimenter behavior, or other experimenter characteristics, e.g., sex, age, race/ethnicity or professional status. More general applications are possible, for example in psychological research such as bias research, or virtual reality research. Potential applications also exist for standardizing clinical research by documenting and communicating instructions used in clinical trials.
Cho, S H; Lowenstein, J R; Balter, P A; Wells, N H; Hanson, W F
2000-01-01
A new calibration protocol, developed by the AAPM Task Group 51 (TG-51) to replace the TG-21 protocol, is based on an absorbed-dose to water standard and calibration factor (N(D,w)), while the TG-21 protocol is based on an exposure (or air-kerma) standard and calibration factor (N(x)). Because of differences between these standards and the two protocols, the results of clinical reference dosimetry based on TG-51 may be somewhat different from those based on TG-21. The Radiological Physics Center has conducted a systematic comparison between the two protocols, in which photon and electron beam outputs following both protocols were compared under identical conditions. Cylindrical chambers used in this study were selected from the list given in the TG-51 report, covering the majority of current manufacturers. Measured ratios between absorbed-dose and air-kerma calibration factors, derived from the standards traceable to the NIST, were compared with calculated values using the TG-21 protocol. The comparison suggests that there is roughly a 1% discrepancy between measured and calculated ratios. This discrepancy may provide a reasonable measure of possible changes between the absorbed-dose to water determined by TG-51 and that determined by TG-21 for photon beam calibrations. The typical change in a 6 MV photon beam calibration following the implementation of the TG-51 protocol was about 1%, regardless of the chamber used, and the change was somewhat smaller for an 18 MV photon beam. On the other hand, the results for 9 and 16 MeV electron beams show larger changes up to 2%, perhaps because of the updated electron stopping power data used for the TG-51 protocol, in addition to the inherent 1% discrepancy presented in the calibration factors. The results also indicate that the changes may be dependent on the electron energy.
Correlation Between Iron and alpha and pi Glutathione-S-Transferase Levels in Humans
2012-09-01
assays were performed as described in the Biotrin High Sensitivity Alpha GST EIA kit protocol. First, serum samples were diluted 1:10 with wash solution...immunosorbent assays were performed as described in the Biotrin Pi GST EIA kit protocol. First, plasma samples were diluted 1:5 with sample diluent...immunosorbent assays were performed as described in the AssayMax Human Transferrin ELISA kit protocol. First, serum samples were diluted 1:2000 with MIX
Updated archaeointensity dataset from the SW Pacific
NASA Astrophysics Data System (ADS)
Hill, Mimi; Nilsson, Andreas; Holme, Richard; Hurst, Elliot; Turner, Gillian; Herries, Andy; Sheppard, Peter
2016-04-01
It is well known that there are far more archaeomagnetic data from the Northern Hemisphere than from the Southern. Here we present a compilation of archaeointensity data from the SW Pacific region covering the past 3000 years. The results have primarily been obtained from a collection of ceramics from the SW Pacific Islands including Fiji, Tonga, Papua New Guinea, New Caledonia and Vanuatu. In addition we present results obtained from heated clay balls from Australia. The microwave method has predominantly been used with a variety of experimental protocols including IZZI and Coe variants. Standard Thellier archaeointensity experiments using the IZZI protocol have also been carried out on selected samples. The dataset is compared to regional predictions from current global geomagnetic field models, and the influence of the new data on constraining the pfm9k family of global geomagnetic field models is explored.
In Situ Quantification of [Re(CO) 3] + by Fluorescence Spectroscopy in Simulated Hanford Tank Waste
DOE Office of Scientific and Technical Information (OSTI.GOV)
Branch, Shirmir D.; French, Amanda D.; Lines, Amanda M.
A pretreatment protocol is presented that allows for the quantitative conversion and subsequent in situ spectroscopic analysis of [Re(CO)3]+ species in simulated Hanford tank waste. The protocol encompasses adding a simulated waste sample containing the non-emissive [Re(CO)3]+ species to a developer solution that enables the rapid, quantitative conversion of the non-emissive species to a luminescent species which can then be detected spectroscopically. The [Re(CO)3]+ species concentration in an alkaline, simulated Hanford tank waste supernatant can be quantified by the standard addition method. In a test case, the [Re(CO)3]+ species was measured to be at a concentration of 38.9 µM, whichmore » was a difference of 2.01% from the actual concentration of 39.7 µM.« less
A protocol for lifetime energy and environmental impact assessment of building insulation materials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shrestha, Som S., E-mail: shresthass@ornl.gov; Biswas, Kaushik; Desjarlais, Andre O.
This article describes a proposed protocol that is intended to provide a comprehensive list of factors to be considered in evaluating the direct and indirect environmental impacts of building insulation materials, as well as detailed descriptions of standardized calculation methodologies to determine those impacts. The energy and environmental impacts of insulation materials can generally be divided into two categories: (1) direct impact due to the embodied energy of the insulation materials and other factors and (2) indirect or environmental impacts avoided as a result of reduced building energy use due to addition of insulation. Standards and product category rules exist,more » which provide guidelines about the life cycle assessment (LCA) of materials, including building insulation products. However, critical reviews have suggested that these standards fail to provide complete guidance to LCA studies and suffer from ambiguities regarding the determination of the environmental impacts of building insulation and other products. The focus of the assessment protocol described here is to identify all factors that contribute to the total energy and environmental impacts of different building insulation products and, more importantly, provide standardized determination methods that will allow comparison of different insulation material types. Further, the intent is not to replace current LCA standards but to provide a well-defined, easy-to-use comparison method for insulation materials using existing LCA guidelines. - Highlights: • We proposed a protocol to evaluate the environmental impacts of insulation materials. • The protocol considers all life cycle stages of an insulation material. • Both the direct environmental impacts and the indirect impacts are defined. • Standardized calculation methods for the ‘avoided operational energy’ is defined. • Standardized calculation methods for the ‘avoided environmental impact’ is defined.« less
Tissue Sampling Guides for Porcine Biomedical Models.
Albl, Barbara; Haesner, Serena; Braun-Reichhart, Christina; Streckel, Elisabeth; Renner, Simone; Seeliger, Frank; Wolf, Eckhard; Wanke, Rüdiger; Blutke, Andreas
2016-04-01
This article provides guidelines for organ and tissue sampling adapted to porcine animal models in translational medical research. Detailed protocols for the determination of sampling locations and numbers as well as recommendations on the orientation, size, and trimming direction of samples from ∼50 different porcine organs and tissues are provided in the Supplementary Material. The proposed sampling protocols include the generation of samples suitable for subsequent qualitative and quantitative analyses, including cryohistology, paraffin, and plastic histology; immunohistochemistry;in situhybridization; electron microscopy; and quantitative stereology as well as molecular analyses of DNA, RNA, proteins, metabolites, and electrolytes. With regard to the planned extent of sampling efforts, time, and personnel expenses, and dependent upon the scheduled analyses, different protocols are provided. These protocols are adjusted for (I) routine screenings, as used in general toxicity studies or in analyses of gene expression patterns or histopathological organ alterations, (II) advanced analyses of single organs/tissues, and (III) large-scale sampling procedures to be applied in biobank projects. Providing a robust reference for studies of porcine models, the described protocols will ensure the efficiency of sampling, the systematic recovery of high-quality samples representing the entire organ or tissue as well as the intra-/interstudy comparability and reproducibility of results. © The Author(s) 2016.
Pinkerton, Steven D.; Pearson, Cynthia R.; Eachus, Susan R.; Berg, Karina M.; Grimes, Richard M.
2008-01-01
Summary Maximizing our economic investment in HIV prevention requires balancing the costs of candidate interventions against their effects and selecting the most cost-effective interventions for implementation. However, many HIV prevention intervention trials do not collect cost information, and those that do use a variety of cost data collection methods and analysis techniques. Standardized cost data collection procedures, instrumentation, and analysis techniques are needed to facilitate the task of assessing intervention costs and to ensure comparability across intervention trials. This article describes the basic elements of a standardized cost data collection and analysis protocol and outlines a computer-based approach to implementing this protocol. Ultimately, the development of such a protocol would require contributions and “buy-in” from a diverse range of stakeholders, including HIV prevention researchers, cost-effectiveness analysts, community collaborators, public health decision makers, and funding agencies. PMID:18301128
The Behavior of TCP and Its Extensions in Space
NASA Technical Reports Server (NTRS)
Wang, Ruhai; Horan, Stephen
2001-01-01
The performance of Transmission Control Protocol (TCP) in space has been examined from the observations of simulation and experimental tests for several years at National Aeronautics and Space Administration (NASA), Department of Defense (DoD) and universities. At New Mexico State University (NMSU), we have been concentrating on studying the performance of two protocol suites: the file transfer protocol (ftp) running over Transmission Control Protocol/Internet Protocol (TCP/IP) stack and the file protocol (fp) running over the Space Communications Protocol Standards (SCPS)-Transport Protocol (TP) developed under the Consultative Committee for Space Data Systems (CCSDS) standards process. SCPS-TP is considered to be TCP's extensions for space communications. This dissertation experimentally studies the behavior of TCP and SCPS-TP by running the protocol suites over both the Space-to-Ground Link Simulator (SGLS) test-bed and realistic satellite link. The study concentrates on comparing protocol behavior by plotting the averaged file transfer times for different experimental configurations and analyzing them using Statistical Analysis System (SAS) based procedures. The effects of different link delays and various Bit-Error-Rates (BERS) on each protocol performance are also studied and linear regression models are built for experiments over SGLS test-bed to reflect the relationships between the file transfer time and various transmission conditions.
Lead Sampling Protocols: Why So Many and What Do They Tell You?
Sampling protocols can be broadly categorized based on their intended purpose of 1) Pb regulatory compliance/corrosion control efficacy, 2) Pb plumbing source determination or Pb type identification, and 3) Pb exposure assessment. Choosing the appropriate protocol is crucial to p...
NHEXAS PHASE I MARYLAND STUDY--LIST OF AVAILABLE DOCUMENTS: PROTOCOLS AND SOPS
This document lists available protocols and SOPs for the NHEXAS Phase I Maryland study. It identifies protocols and SOPs for the following study components: (1) Sample collection and field operations, (2) Sample analysis and general laboratory procedures, (3) Data Analysis Proced...
Hisao, Grant S; Harland, Michael A; Brown, Robert A; Berthold, Deborah A; Wilson, Thomas E; Rienstra, Chad M
2016-04-01
The study of mass-limited biological samples by magic angle spinning (MAS) solid-state NMR spectroscopy critically relies upon the high-yield transfer of material from a biological preparation into the MAS rotor. This issue is particularly important for maintaining biological activity and hydration of semi-solid samples such as membrane proteins in lipid bilayers, pharmaceutical formulations, microcrystalline proteins and protein fibrils. Here we present protocols and designs for rotor-packing devices specifically suited for packing hydrated samples into Pencil-style 1.6 mm, 3.2 mm standard, and 3.2 mm limited speed MAS rotors. The devices are modular and therefore readily adaptable to other rotor and/or ultracentrifugation tube geometries. Copyright © 2016 Elsevier Inc. All rights reserved.
Marron, Alan O; Akam, Michael; Walker, Giselle
2013-01-01
Cultures of heterotrophic protists often require co-culturing with bacteria to act as a source of nutrition. Such cultures will contain varying levels of intrinsic bacterial contamination that can interfere with molecular research and cause problems with the collection of sufficient material for sequencing. Measuring the levels of bacterial contamination for the purposes of molecular biology research is non-trivial, and can be complicated by the presence of a diverse bacterial flora, or by differences in the relative nucleic acid yield per bacterial or eukaryotic cell. Here we describe a duplex PCR-based assay that can be used to measure the levels of contamination from marine bacteria in a culture of loricate choanoflagellates. By comparison to a standard culture of known target sequence content, the assay can be used to quantify the relative proportions of bacterial and choanoflagellate material in DNA or RNA samples extracted from a culture. We apply the assay to compare methods of purifying choanoflagellate cultures prior to DNA extraction, to determine their effectiveness in reducing bacterial contamination. Together with measurements of the total nucleic acid concentration, the assay can then be used as the basis for determining the absolute amounts of choanoflagellate DNA or RNA present in a sample. The assay protocol we describe here is a simple and relatively inexpensive method of measuring contamination levels in nucleic acid samples. This provides a new way to establish quantification and purification protocols for molecular biology and genomics in novel heterotrophic protist species. Guidelines are provided to develop a similar protocol for use with any protistan culture. This assay method is recommended where qPCR equipment is unavailable, where qPCR is not viable because of the nature of the bacterial contamination or starting material, or where prior sequence information is insufficient to develop qPCR protocols.
Sunstrom, Rachel; Hamilton, Nicholas; Fialkowski, Elizabeth; Lofberg, Katrine; McKee, Julie; Sims, Thomas; Krishnaswami, Sanjay; Azarow, Kenneth
2016-05-01
A protocol for laparoscopic gastrostomy placement was implemented which specified perioperative antibiotics, feeding regimens, and discharge criteria. Our hypothesis was that hospital cost could be decreased, whereas at the same time improving or maintaining patient outcomes. Data were collected on consecutive patients beginning 6 months after implementation of our protocol. We recorded surgeon compliance, patient outcomes (as defined by 30-day NSQIP complication rates), and cost of initial hospitalization, which was then compare to a 6-month historical control period. Our control group n = 26 and protocol group n = 39. Length of stay was shorter in the protocol group (P ≤ .05 by nonparametric analysis). The complication rate was similar in both groups (23% control vs 15% protocol, P = .43). Initial hospital costs were not different. Surgeon compliance to protocol was 82%. A standard protocol is achievable for gastrostomy tube management. After implementation of our protocol, we were able to show a significant decrease in length of stay, whereas maintaining quality. Copyright © 2016 Elsevier Inc. All rights reserved.
Wireless Communications in Space
NASA Technical Reports Server (NTRS)
2004-01-01
In 1992, NASA and the U.S. Department of Defense jointly commissioned the research and development of a technology solution to address the challenges and requirements of communicating with their spacecraft. The project yielded an international consortium composed of representatives from the space science community, industry, and academia. This group of experts developed a broad suite of protocols specifically designed for space-based communications, known today as Space Communications Protocol Standards (SCPS). Having been internationally standardized by the Consultative Committee on Space Data Systems and the International Standards Organization, SCPS is distributed as open source technology by NASA s Jet Propulsion Laboratory (JPL). The protocols are used for every national space mission that takes place today.
Integrated Data Collection Analysis (IDCA) Program - RDX Type II Class 5 Standard, Data Set 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sandstrom, Mary M.; Brown, Geoffrey W.; Preston, Daniel N.
This document describes the results of the first reference sample material—RDX Type II Class 5—examined in the proficiency study for small-scale safety and thermal (SSST) testing of explosive materials for the Integrated Data Collection Analysis (IDCA) Program. The IDCA program is conducting proficiency testing on homemade explosives (HMEs). The reference sample materials are being studied to establish the accuracy of traditional explosives safety testing for each performing laboratory. These results will be used for comparison to results from testing HMEs. This effort, funded by the Department of Homeland Security (DHS), ultimately will put the issues of safe handling of thesemore » materials in perspective with standard military explosives. The results of the study will add SSST testing results for a broad suite of different HMEs to the literature, potentially suggest new guidelines and methods for HME testing, and possibly establish what are the needed accuracies in SSST testing to develop safe handling practices. Described here are the results for impact, friction, electrostatic discharge, and scanning calorimetry analysis of a reference sample of RDX Type II Class 5. The results from each participating testing laboratory are compared using identical test material and preparation methods wherever possible. Note, however, the test procedures differ among the laboratories. These results are then compared to historical data from various sources. The performers involved are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Air Force Research Laboratory/ RXQL (AFRL), Indian Head Division, Naval Surface Warfare Center, (IHD-NSWC), and Sandia National Laboratories (SNL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to understand how to compare results when test protocols are not identical.« less
Large-Scale Spatial Distribution Patterns of Gastropod Assemblages in Rocky Shores
Miloslavich, Patricia; Cruz-Motta, Juan José; Klein, Eduardo; Iken, Katrin; Weinberger, Vanessa; Konar, Brenda; Trott, Tom; Pohle, Gerhard; Bigatti, Gregorio; Benedetti-Cecchi, Lisandro; Shirayama, Yoshihisa; Mead, Angela; Palomo, Gabriela; Ortiz, Manuel; Gobin, Judith; Sardi, Adriana; Díaz, Juan Manuel; Knowlton, Ann; Wong, Melisa; Peralta, Ana C.
2013-01-01
Gastropod assemblages from nearshore rocky habitats were studied over large spatial scales to (1) describe broad-scale patterns in assemblage composition, including patterns by feeding modes, (2) identify latitudinal pattern of biodiversity, i.e., richness and abundance of gastropods and/or regional hotspots, and (3) identify potential environmental and anthropogenic drivers of these assemblages. Gastropods were sampled from 45 sites distributed within 12 Large Marine Ecosystem regions (LME) following the NaGISA (Natural Geography in Shore Areas) standard protocol (www.nagisa.coml.org). A total of 393 gastropod taxa from 87 families were collected. Eight of these families (9.2%) appeared in four or more different LMEs. Among these, the Littorinidae was the most widely distributed (8 LMEs) followed by the Trochidae and the Columbellidae (6 LMEs). In all regions, assemblages were dominated by few species, the most diverse and abundant of which were herbivores. No latitudinal gradients were evident in relation to species richness or densities among sampling sites. Highest diversity was found in the Mediterranean and in the Gulf of Alaska, while highest densities were found at different latitudes and represented by few species within one genus (e.g. Afrolittorina in the Agulhas Current, Littorina in the Scotian Shelf, and Lacuna in the Gulf of Alaska). No significant correlation was found between species composition and environmental variables (r≤0.355, p>0.05). Contributing variables to this low correlation included invasive species, inorganic pollution, SST anomalies, and chlorophyll-a anomalies. Despite data limitations in this study which restrict conclusions in a global context, this work represents the first effort to sample gastropod biodiversity on rocky shores using a standardized protocol across a wide scale. Our results will generate more work to build global databases allowing for large-scale diversity comparisons of rocky intertidal assemblages. PMID:23967204
Gigabit Ethernet: A Technical Assessment.
ERIC Educational Resources Information Center
Axner, David
1997-01-01
Describes gigabit ethernet for LAN (local area network) technology that will expand ethernet bandwidth. Technical details are discussed, including protocol stacks, optical fiber, deployment strategy for performance improvement, ATM (Asynchronous Transfer Mode), real-time protocol, reserve reservation protocol, and standards. (LRW)
EPA Traceability Protocol for Assay and Certification of Gaseous Calibration Standards
EPA's air monitoring regulations require the use of Protocol Gases to set air pollution monitors. This protocol balances the government's need for accuracy with the producers' need for flexibility, low cost, and minimum external oversight.
None
2014-12-01
The recent development of methods applying next-generation sequencing to microbial community characterization has led to the proliferation of these studies in a wide variety of sample types. Yet, variation in the physical properties of environmental samples demands that optimal DNA extraction techniques be explored for each new environment. The microbiota associated with many species of insects offer an extraction challenge as they are frequently surrounded by an armored exoskeleton, inhibiting disruption of the tissues within. In this study, we examine the efficacy of several commonly used protocols for extracting bacterial DNA from ants. While bacterial community composition recovered using Illuminamore » 16S rRNA amplicon sequencing was not detectably biased by any method, the quantity of bacterial DNA varied drastically, reducing the number of samples that could be amplified and sequenced. These results indicate that the concentration necessary for dependable sequencing is around 10,000 copies of target DNA per microliter. Exoskeletal pulverization and tissue digestion increased the reliability of extractions, suggesting that these steps should be included in any study of insect-associated microorganisms that relies on obtaining microbial DNA from intact body segments. Although laboratory and analysis techniques should be standardized across diverse sample types as much as possible, minimal modifications such as these will increase the number of environments in which bacterial communities can be successfully studied.« less
Preparation of Low-Input and Ligation-Free ChIP-seq Libraries Using Template-Switching Technology.
Bolduc, Nathalie; Lehman, Alisa P; Farmer, Andrew
2016-10-10
Chromatin immunoprecipitation (ChIP) followed by high-throughput sequencing (ChIP-seq) has become the gold standard for mapping of transcription factors and histone modifications throughout the genome. However, for ChIP experiments involving few cells or targeting low-abundance transcription factors, the small amount of DNA recovered makes ligation of adapters very challenging. In this unit, we describe a ChIP-seq workflow that can be applied to small cell numbers, including a robust single-tube and ligation-free method for preparation of sequencing libraries from sub-nanogram amounts of ChIP DNA. An example ChIP protocol is first presented, resulting in selective enrichment of DNA-binding proteins and cross-linked DNA fragments immobilized on beads via an antibody bridge. This is followed by a protocol for fast and easy cross-linking reversal and DNA recovery. Finally, we describe a fast, ligation-free library preparation protocol, featuring DNA SMART technology, resulting in samples ready for Illumina sequencing. © 2016 by John Wiley & Sons, Inc. Copyright © 2016 John Wiley & Sons, Inc.
NASA Technical Reports Server (NTRS)
Bomani, Bilal Mark McDowell; Link, Dirk; Kail, Brian; Morreale, Bryan; Lee, Eric S.; Gigante, Bethany M.; Hendricks, Robert C.
2014-01-01
Finding a viable and sustainable source of renewable energy is a global task. Biofuels as a renewable energy source can potentially be a viable option for sustaining long-term energy needs. Biodiesel from halophytes shows great promise due to their ability to serve not only as a fuel source, but a food source as well. Halophytes are one of the few biomass plant species that can tolerate a wide range of saline conditions. We investigate the feasibility of using the halophyte, Salicornia virginica as a biofuel source by conducting a series of experiments utilizing various growth and salinity conditions. The goal is to determine if the saline content of Salicornia virginica in our indoor growth vs outdoor growth conditions has an influence on lipid recovery and total biomass composition. We focused on using standard lipid extraction protocols and characterization methods to evaluate twelve Salicornia virginica samples under six saline values ranging from freshwater to seawater and two growth conditions. The overall goal is to develop an optimal lipid extraction protocol for Salicornia virginica and potentially apply this protocol to halophytes in general.
Rota, Paola; Anastasia, Luigi; Allevi, Pietro
2015-05-07
The current analytical protocol used for the GC-MS determination of free or 1,7-lactonized natural sialic acids (Sias), as heptafluorobutyrates, overlooks several transformations. Using authentic reference standards and by combining GC-MS and NMR analyses, flaws in the analytical protocol were pinpointed and elucidated, thus establishing the scope and limitations of the method. It was demonstrated that (a) Sias 1,7-lactones, even if present in biological samples, decompose under the acidic hydrolysis conditions used for their release; (b) Sias 1,7-lactones are unpredicted artifacts, accidentally generated from their parent acids; (c) the N-acetyl group is quantitatively exchanged with that of the derivatizing perfluorinated anhydride; (d) the partial or complete failure of the Sias esterification-step with diazomethane leads to the incorrect quantification and structure attribution of all free Sias. While these findings prompt an urgent correction and improvement of the current analytical protocol, they could be instrumental for a critical revision of many incorrect claims reported in the literature.
Gandolfi, Marialuisa; Smania, Nicola; Bisoffi, Giulia; Squaquara, Teresa; Zuccher, Paola; Mazzucco, Sara
2014-12-01
Stroke is a major cause of dysphagia. Few studies to date have reported on standardized multidisciplinary protocolized approaches to the management of post-stroke dysphagia. The aim of this retrospective cohort study was to evaluate the impact of a standardized multidisciplinary protocol on clinical outcomes in patients with post-stroke dysphagia. We performed retrospective chart reviews of patients with post-stroke dysphagia admitted to the neurological ward of Verona University Hospital from 2004 to 2008. Outcomes after usual treatment for dysphagia (T- group) were compared versus outcomes after treatment under a standardized diagnostic and rehabilitative multidisciplinary protocol (T+ group). Outcome measures were death, pneumonia on X-ray, need for respiratory support, and proportion of patients on tube feeding at discharge. Of the 378 patients admitted with stroke, 84 had dysphagia and were enrolled in the study. A significantly lower risk of in-hospital death (odds ratio [OR] 0.20 [0.53-0.78]), pneumonia (OR 0.33 [0.10-1.03]), need for respiratory support (OR 0.48 [0.14-1.66]), and tube feeding at discharge (OR 0.30 [0.09-0.91]) was recorded for the T+ group (N = 39) as compared to the T- group (N = 45). The adjusted OR showed no difference between the two groups for in-hospital death and tube feeding at discharge. Use of a standardized multidisciplinary protocolized approach to the management of post-stroke dysphagia may significantly reduce rates of aspiration pneumonia, in-hospital mortality, and tube feeding in dysphagic stroke survivors. Consistent with the study's exploratory purposes, our findings suggest that the multidisciplinary protocol applied in this study offers an effective model of management of post-stroke dysphagia.