Sample records for standardized test protocol

  1. Comparison of test protocols for standard room/corner tests

    Treesearch

    R. H. White; M. A. Dietenberger; H. Tran; O. Grexa; L. Richardson; K. Sumathipala; M. Janssens

    1998-01-01

    As part of international efforts to evaluate alternative reaction-to-fire tests, several series of room/comer tests have been conducted. This paper reviews the overall results of related projects in which different test protocols for standard room/corner tests were used. Differences in the test protocols involved two options for the ignition burner scenario and whether...

  2. A proposed protocol for acceptance and constancy control of computed tomography systems: a Nordic Association for Clinical Physics (NACP) work group report.

    PubMed

    Kuttner, Samuel; Bujila, Robert; Kortesniemi, Mika; Andersson, Henrik; Kull, Love; Østerås, Bjørn Helge; Thygesen, Jesper; Tarp, Ivanka Sojat

    2013-03-01

    Quality assurance (QA) of computed tomography (CT) systems is one of the routine tasks for medical physicists in the Nordic countries. However, standardized QA protocols do not yet exist and the QA methods, as well as the applied tolerance levels, vary in scope and extent at different hospitals. To propose a standardized protocol for acceptance and constancy testing of CT scanners in the Nordic Region. Following a Nordic Association for Clinical Physics (NACP) initiative, a group of medical physicists, with representatives from four Nordic countries, was formed. Based on international literature and practical experience within the group, a comprehensive standardized test protocol was developed. The proposed protocol includes tests related to the mechanical functionality, X-ray tube, detector, and image quality for CT scanners. For each test, recommendations regarding the purpose, equipment needed, an outline of the test method, the measured parameter, tolerance levels, and the testing frequency are stated. In addition, a number of optional tests are briefly discussed that may provide further information about the CT system. Based on international references and medical physicists' practical experiences, a comprehensive QA protocol for CT systems is proposed, including both acceptance and constancy tests. The protocol may serve as a reference for medical physicists in the Nordic countries.

  3. 16 CFR 1210.4 - Test protocol.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 16 Commercial Practices 2 2012-01-01 2012-01-01 false Test protocol. 1210.4 Section 1210.4... STANDARD FOR CIGARETTE LIGHTERS Requirements for Child Resistance § 1210.4 Test protocol. (a) Child test panel. (1) The test to determine if a lighter is resistant to successful operation by children uses a...

  4. 16 CFR 1212.4 - Test protocol.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 16 Commercial Practices 2 2012-01-01 2012-01-01 false Test protocol. 1212.4 Section 1212.4... STANDARD FOR MULTI-PURPOSE LIGHTERS Requirements for Child-Resistance § 1212.4 Test protocol. (a) Child test panel. (1) The test to determine if a multi-purpose lighter is resistant to successful operation...

  5. Telemetry Standards, RCC Standard 106-17. Chapter 21. Telemetry Network Standard Introduction

    DTIC Science & Technology

    2017-07-01

    Critical RF radio frequency RFC Request for Comment SNMP Simple Network Management Protocol TA test article TCP Transmission Control Protocol...chapters might be of most interest for a particular reader. In order to guide the reader toward the chapters of further interest , the applicable... Simple Network Management Protocol (SNMP) to pass management information through the system. The SNMP management information bases (MIBs) provide

  6. Modified Test Protocol Improves Sensitivity of the Stereo Fly Test.

    PubMed

    De La Cruz, Angie; Morale, Sarah E; Jost, Reed M; Kelly, Krista R; Birch, Eileen E

    2016-01-01

    Stereoacuity measurement is a common element of pediatric ophthalmic examinations. Although the Stereo Fly Test is routinely used to establish the presence of coarse stereopsis (3000 arcsecs), it often yields a false negative "pass" due to learned responses and non-stereoscopic cues. We developed and evaluated a modified Stereo Fly Test protocol aimed at increasing sensitivity, thus reducing false negatives. The Stereo Fly Test was administered according to manufacturer instructions to 321 children aged 3-12 years. Children with a "pass" outcome (n = 147) were re-tested wearing glasses fitted with polarizers of matching orientation for both eyes to verify that they were responding to stereoscopic cues (modified protocol). The response to the standard Stereo Fly Test was considered a false negative (pass) if the child still pinched above the plate after disparity cues were eliminated. Randot ® Preschool Stereoacuity and Butterfly Tests were used as gold standards. Sensitivity was 81% (95% CI: 0.75 - 0.86) for standard administration of the Stereo Fly Test (19% false negative "pass"). The modified protocol increased sensitivity to 90% (95% CI: 0.85 - 0.94). The modified two-step protocol is a simple and convenient way to administer the Stereo Fly Test with increased sensitivity in a clinical setting. © 2016 Board of regents of the University of Wisconsin System, American Orthoptic Journal, Volume 66, 2016, ISSN 0065-955X, E-ISSN 1553-4448.

  7. Prediction of anaerobic power values from an abbreviated WAnT protocol.

    PubMed

    Stickley, Christopher D; Hetzler, Ronald K; Kimura, Iris F

    2008-05-01

    The traditional 30-second Wingate anaerobic test (WAnT) is a widely used anaerobic power assessment protocol. An abbreviated protocol has been shown to decrease the mild to severe physical discomfort often associated with the WAnT. Therefore, the purpose of this study was to determine whether a 20-second WAnT protocol could be used to accurately predict power values of a standard 30-second WAnT. In 96 college females, anaerobic power variables were assessed using a standard 30-second WAnT protocol. Maximum power values as well as instantaneous power at 10, 15, and 20 seconds were recorded. Based on these results, stepwise regression analysis was performed to determine the accuracy with which mean power, minimum power, 30-second power, and percentage of fatigue for a standard 30-second WAnT could be predicted from values obtained during the first 20 seconds of testing. Mean power values showed the highest level of predictability (R2 = 0.99) from the 20-second values. Minimum power, 30-second power, and percentage of fatigue also showed high levels of predictability (R2 = 0.91, 0.84, and 0.84, respectively) using only values obtained during the first 20 seconds of the protocol. An abbreviated (20-second) WAnT protocol appears to effectively predict results of a standard 30-second WAnT in college-age females, allowing for comparison of data to published norms. A shortened test may allow for a decrease in unwanted side effects associated with the traditional WAnT protocol.

  8. High SNR Acquisitions Improve the Repeatability of Liver Fat Quantification Using Confounder-corrected Chemical Shift-encoded MR Imaging

    PubMed Central

    Motosugi, Utaroh; Hernando, Diego; Wiens, Curtis; Bannas, Peter; Reeder, Scott. B

    2017-01-01

    Purpose: To determine whether high signal-to-noise ratio (SNR) acquisitions improve the repeatability of liver proton density fat fraction (PDFF) measurements using confounder-corrected chemical shift-encoded magnetic resonance (MR) imaging (CSE-MRI). Materials and Methods: Eleven fat-water phantoms were scanned with 8 different protocols with varying SNR. After repositioning the phantoms, the same scans were repeated to evaluate the test-retest repeatability. Next, an in vivo study was performed with 20 volunteers and 28 patients scheduled for liver magnetic resonance imaging (MRI). Two CSE-MRI protocols with standard- and high-SNR were repeated to assess test-retest repeatability. MR spectroscopy (MRS)-based PDFF was acquired as a standard of reference. The standard deviation (SD) of the difference (Δ) of PDFF measured in the two repeated scans was defined to ascertain repeatability. The correlation between PDFF of CSE-MRI and MRS was calculated to assess accuracy. The SD of Δ and correlation coefficients of the two protocols (standard- and high-SNR) were compared using F-test and t-test, respectively. Two reconstruction algorithms (complex-based and magnitude-based) were used for both the phantom and in vivo experiments. Results: The phantom study demonstrated that higher SNR improved the repeatability for both complex- and magnitude-based reconstruction. Similarly, the in vivo study demonstrated that the repeatability of the high-SNR protocol (SD of Δ = 0.53 for complex- and = 0.85 for magnitude-based fit) was significantly higher than using the standard-SNR protocol (0.77 for complex, P < 0.001; and 0.94 for magnitude-based fit, P = 0.003). No significant difference was observed in the accuracy between standard- and high-SNR protocols. Conclusion: Higher SNR improves the repeatability of fat quantification using confounder-corrected CSE-MRI. PMID:28190853

  9. 34 CFR 462.3 - What definitions apply?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... items across pre- and post-testing. Test administrator means an individual who is trained to administer... instructional time a student needs before post-testing. Violation of these protocols often invalidates the test... defined in the Act. Test means a standardized test, assessment, or instrument that has a formal protocol...

  10. 34 CFR 462.3 - What definitions apply?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... items across pre- and post-testing. Test administrator means an individual who is trained to administer... instructional time a student needs before post-testing. Violation of these protocols often invalidates the test... defined in the Act. Test means a standardized test, assessment, or instrument that has a formal protocol...

  11. 34 CFR 462.3 - What definitions apply?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... items across pre- and post-testing. Test administrator means an individual who is trained to administer... instructional time a student needs before post-testing. Violation of these protocols often invalidates the test... defined in the Act. Test means a standardized test, assessment, or instrument that has a formal protocol...

  12. 34 CFR 462.3 - What definitions apply?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... items across pre- and post-testing. Test administrator means an individual who is trained to administer... instructional time a student needs before post-testing. Violation of these protocols often invalidates the test... defined in the Act. Test means a standardized test, assessment, or instrument that has a formal protocol...

  13. 34 CFR 462.3 - What definitions apply?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... items across pre- and post-testing. Test administrator means an individual who is trained to administer... instructional time a student needs before post-testing. Violation of these protocols often invalidates the test... defined in the Act. Test means a standardized test, assessment, or instrument that has a formal protocol...

  14. Extended Theories of Gravitation. Observation Protocols and Experimental Tests

    NASA Astrophysics Data System (ADS)

    Fatibene, Lorenzo; Ferraris, Marco; Francaviglia, Mauro; Magnano, Guido

    2013-09-01

    Within the framework of extended theories of gravitation we shall discuss physical equivalences among different formalisms and classical tests. As suggested by the Ehlers-Pirani-Schild framework, the conformal invariance will be preserved and its effect on observational protocols discussed. Accordingly, we shall review standard tests showing how Palatini f(R)-theories naturally passes solar system tests. Observation protocols will be discussed in this wider framework.

  15. Non-Intrusive Load Monitoring Assessment: Literature Review and Laboratory Protocol

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Butner, R. Scott; Reid, Douglas J.; Hoffman, Michael G.

    2013-07-01

    To evaluate the accuracy of NILM technologies, a literature review was conducted to identify any test protocols or standardized testing approaches currently in use. The literature review indicated that no consistent conventions were currently in place for measuring the accuracy of these technologies. Consequently, PNNL developed a testing protocol and metrics to provide the basis for quantifying and analyzing the accuracy of commercially available NILM technologies. This report discusses the results of the literature review and the proposed test protocol and metrics in more detail.

  16. Protocol and standard operating procedures for common use in a worldwide multicenter study on reference values.

    PubMed

    Ozarda, Yesim; Ichihara, Kiyoshi; Barth, Julian H; Klee, George

    2013-05-01

    The reference intervals (RIs) given in laboratory reports have an important role in aiding clinicians in interpreting test results in reference to values of healthy populations. In this report, we present a proposed protocol and standard operating procedures (SOPs) for common use in conducting multicenter RI studies on a national or international scale. The protocols and consensus on their contents were refined through discussions in recent C-RIDL meetings. The protocol describes in detail (1) the scheme and organization of the study, (2) the target population, inclusion/exclusion criteria, ethnicity, and sample size, (3) health status questionnaire, (4) target analytes, (5) blood collection, (6) sample processing and storage, (7) assays, (8) cross-check testing, (9) ethics, (10) data analyses, and (11) reporting of results. In addition, the protocol proposes the common measurement of a panel of sera when no standard materials exist for harmonization of test results. It also describes the requirements of the central laboratory, including the method of cross-check testing between the central laboratory of each country and local laboratories. This protocol and the SOPs remain largely exploratory and may require a reevaluation from the practical point of view after their implementation in the ongoing worldwide study. The paper is mainly intended to be a basis for discussion in the scientific community.

  17. Determining contrast medium dose and rate on basis of lean body weight: does this strategy improve patient-to-patient uniformity of hepatic enhancement during multi-detector row CT?

    PubMed

    Ho, Lisa M; Nelson, Rendon C; Delong, David M

    2007-05-01

    To prospectively evaluate the use of lean body weight (LBW) as the main determinant of the volume and rate of contrast material administration during multi-detector row computed tomography of the liver. This HIPAA-compliant study had institutional review board approval. All patients gave written informed consent. Four protocols were compared. Standard protocol involved 125 mL of iopamidol injected at 4 mL/sec. Total body weight (TBW) protocol involved 0.7 g iodine per kilogram of TBW. Calculated LBW and measured LBW protocols involved 0.86 g of iodine per kilogram and 0.92 g of iodine per kilogram calculated or measured LBW for men and women, respectively. Injection rate used for the three experimental protocols was determined proportionally on the basis of the calculated volume of contrast material. Postcontrast attenuation measurements during portal venous phase were obtained in liver, portal vein, and aorta for each group and were summed for each patient. Patient-to-patient enhancement variability in same group was measured with Levene test. Two-tailed t test was used to compare the three experimental protocols with the standard protocol. Data analysis was performed in 101 patients (25 or 26 patients per group), including 56 men and 45 women (mean age, 53 years). Average summed attenuation values for standard, TBW, calculated LBW, and measured LBW protocols were 419 HU +/- 50 (standard deviation), 443 HU +/- 51, 433 HU +/- 50, and 426 HU +/- 33, respectively (P = not significant for all). Levene test results for summed attenuation data for standard, TBW, calculated LBW, and measured LBW protocols were 40 +/- 29, 38 +/- 33 (P = .83), 35 +/- 35 (P = .56), and 26 +/- 19 (P = .05), respectively. By excluding highly variable but poorly perfused adipose tissue from calculation of contrast medium dose, the measured LBW protocol may lessen patient-to-patient enhancement variability while maintaining satisfactory hepatic and vascular enhancement.

  18. Test Protocols for Advanced Inverter Interoperability Functions – Main Document

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, Jay Dean; Gonzalez, Sigifredo; Ralph, Mark E.

    2013-11-01

    Distributed energy resources (DER) such as photovoltaic (PV) systems, when deployed in a large scale, are capable of influencing significantly the operation of power systems. Looking to the future, stakeholders are working on standards to make it possible to manage the potentially complex interactions between DER and the power system. In 2009, the Electric Power Research Institute (EPRI), Sandia National Laboratories (SNL) with the U.S. Department of Energy (DOE), and the Solar Electric Power Association (SEPA) initiated a large industry collaborative to identify and standardize definitions for a set of DER grid support functions. While the initial effort concentrated onmore » grid-tied PV inverters and energy storage systems, the concepts have applicability to all DER. A partial product of this on-going effort is a reference definitions document (IEC TR 61850-90-7, Object models for power converters in distributed energy resources (DER) systems) that has become a basis for expansion of related International Electrotechnical Commission (IEC) standards, and is supported by US National Institute of Standards and Technology (NIST) Smart Grid Interoperability Panel (SGIP). Some industry-led organizations advancing communications protocols have also embraced this work. As standards continue to evolve, it is necessary to develop test protocols to independently verify that the inverters are properly executing the advanced functions. Interoperability is assured by establishing common definitions for the functions and a method to test compliance with operational requirements. This document describes test protocols developed by SNL to evaluate the electrical performance and operational capabilities of PV inverters and energy storage, as described in IEC TR 61850-90-7. While many of these functions are not currently required by existing grid codes or may not be widely available commercially, the industry is rapidly moving in that direction. Interoperability issues are already apparent as some of these inverter capabilities are being incorporated in large demonstration and commercial projects. The test protocols are intended to be used to verify acceptable performance of inverters within the standard framework described in IEC TR 61850-90-7. These test protocols, as they are refined and validated over time, can become precursors for future certification test procedures for DER advanced grid support functions.« less

  19. Test Protocols for Advanced Inverter Interoperability Functions - Appendices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, Jay Dean; Gonzalez, Sigifredo; Ralph, Mark E.

    2013-11-01

    Distributed energy resources (DER) such as photovoltaic (PV) systems, when deployed in a large scale, are capable of influencing significantly the operation of power systems. Looking to the future, stakeholders are working on standards to make it possible to manage the potentially complex interactions between DER and the power system. In 2009, the Electric Power Research Institute (EPRI), Sandia National Laboratories (SNL) with the U.S. Department of Energy (DOE), and the Solar Electric Power Association (SEPA) initiated a large industry collaborative to identify and standardize definitions for a set of DER grid support functions. While the initial effort concentrated onmore » grid-tied PV inverters and energy storage systems, the concepts have applicability to all DER. A partial product of this on-going effort is a reference definitions document (IEC TR 61850-90-7, Object models for power converters in distributed energy resources (DER) systems) that has become a basis for expansion of related International Electrotechnical Commission (IEC) standards, and is supported by US National Institute of Standards and Technology (NIST) Smart Grid Interoperability Panel (SGIP). Some industry-led organizations advancing communications protocols have also embraced this work. As standards continue to evolve, it is necessary to develop test protocols to independently verify that the inverters are properly executing the advanced functions. Interoperability is assured by establishing common definitions for the functions and a method to test compliance with operational requirements. This document describes test protocols developed by SNL to evaluate the electrical performance and operational capabilities of PV inverters and energy storage, as described in IEC TR 61850-90-7. While many of these functions are not now required by existing grid codes or may not be widely available commercially, the industry is rapidly moving in that direction. Interoperability issues are already apparent as some of these inverter capabilities are being incorporated in large demonstration and commercial projects. The test protocols are intended to be used to verify acceptable performance of inverters within the standard framework described in IEC TR 61850-90-7. These test protocols, as they are refined and validated over time, can become precursors for future certification test procedures for DER advanced grid support functions.« less

  20. The Impact of National Standards Assessment in New Zealand, and National Testing Protocols in Norway on Indigenous Schooling

    ERIC Educational Resources Information Center

    Özerk, Kamil; Whitehead, David

    2012-01-01

    This paper first provides a critic of the implementation of compulsory national assessment protocols internationally, and then nationally through a review of the implementation process used for the introduction of National Standards in New Zealand, and National Testing in Norwegian mainstream schools. It then reviews the impact of these two…

  1. Advances in radiation detection technologies for responders.

    PubMed

    Unterweger, Michael P; Pibida, Leticia S

    2005-11-01

    The Department of Homeland Security is supporting the development of a large number of standards for first responders. In the area of detection of radioactive and nuclear materials, four new standards (ANSI N42.32, N42.33, N42.34, and N42.35) and their corresponding test and evaluation protocols were developed to meet Department of Homeland Security needs. Testing of the standards and protocols was carried out at the National Institute of Standards and Technology, Oak Ridge National Laboratory, Pacific Northwest National Laboratory, Los Alamos National Laboratory, and Lawrence Livermore National Laboratory.

  2. Protocol standards and implementation within the digital engineering laboratory computer network (DELNET) using the universal network interface device (UNID). Part 2

    NASA Astrophysics Data System (ADS)

    Phister, P. W., Jr.

    1983-12-01

    Development of the Air Force Institute of Technology's Digital Engineering Laboratory Network (DELNET) was continued with the development of an initial draft of a protocol standard for all seven layers as specified by the International Standards Organization's (ISO) Reference Model for Open Systems Interconnections. This effort centered on the restructuring of the Network Layer to perform Datagram routing and to conform to the developed protocol standards and actual software module development of the upper four protocol layers residing within the DELNET Monitor (Zilog MCZ 1/25 Computer System). Within the guidelines of the ISO Reference Model the Transport Layer was developed utilizing the Internet Header Format (IHF) combined with the Transport Control Protocol (TCP) to create a 128-byte Datagram. Also a limited Application Layer was created to pass the Gettysburg Address through the DELNET. This study formulated a first draft for the DELNET Protocol Standard and designed, implemented, and tested the Network, Transport, and Application Layers to conform to these protocol standards.

  3. Experimental control in software reliability certification

    NASA Technical Reports Server (NTRS)

    Trammell, Carmen J.; Poore, Jesse H.

    1994-01-01

    There is growing interest in software 'certification', i.e., confirmation that software has performed satisfactorily under a defined certification protocol. Regulatory agencies, customers, and prospective reusers all want assurance that a defined product standard has been met. In other industries, products are typically certified under protocols in which random samples of the product are drawn, tests characteristic of operational use are applied, analytical or statistical inferences are made, and products meeting a standard are 'certified' as fit for use. A warranty statement is often issued upon satisfactory completion of a certification protocol. This paper outlines specific engineering practices that must be used to preserve the validity of the statistical certification testing protocol. The assumptions associated with a statistical experiment are given, and their implications for statistical testing of software are described.

  4. The Behavior of TCP and Its Extensions in Space

    NASA Technical Reports Server (NTRS)

    Wang, Ruhai; Horan, Stephen

    2001-01-01

    The performance of Transmission Control Protocol (TCP) in space has been examined from the observations of simulation and experimental tests for several years at National Aeronautics and Space Administration (NASA), Department of Defense (DoD) and universities. At New Mexico State University (NMSU), we have been concentrating on studying the performance of two protocol suites: the file transfer protocol (ftp) running over Transmission Control Protocol/Internet Protocol (TCP/IP) stack and the file protocol (fp) running over the Space Communications Protocol Standards (SCPS)-Transport Protocol (TP) developed under the Consultative Committee for Space Data Systems (CCSDS) standards process. SCPS-TP is considered to be TCP's extensions for space communications. This dissertation experimentally studies the behavior of TCP and SCPS-TP by running the protocol suites over both the Space-to-Ground Link Simulator (SGLS) test-bed and realistic satellite link. The study concentrates on comparing protocol behavior by plotting the averaged file transfer times for different experimental configurations and analyzing them using Statistical Analysis System (SAS) based procedures. The effects of different link delays and various Bit-Error-Rates (BERS) on each protocol performance are also studied and linear regression models are built for experiments over SGLS test-bed to reflect the relationships between the file transfer time and various transmission conditions.

  5. SCPS-TP, TCP, and Rate-Based Protocol Evaluation. Revised

    NASA Technical Reports Server (NTRS)

    Tran, Diepchi T.; Lawas-Grodek, Frances J.; Dimond, Robert P.; Ivancic, William D.

    2005-01-01

    Tests were performed at Glenn Research Center to compare the performance of the Space Communications Protocol Standard Transport Protocol (SCPS TP, otherwise known as "TCP Tranquility") relative to other variants of TCP and to determine the implementation maturity level of these protocols, particularly for higher speeds. The testing was performed over reasonably high data rates of up to 100 Mbps with delays that are characteristic of near-planetary environments. The tests were run for a fixed packet size, but for variously errored environments. This report documents the testing performed to date.

  6. Abbreviated Combined MR Protocol: A New Faster Strategy for Characterizing Breast Lesions.

    PubMed

    Moschetta, Marco; Telegrafo, Michele; Rella, Leonarda; Stabile Ianora, Amato Antonio; Angelelli, Giuseppe

    2016-06-01

    The use of an abbreviated magnetic resonance (MR) protocol has been recently proposed for cancer screening. The aim of our study is to evaluate the diagnostic accuracy of an abbreviated MR protocol combining short TI inversion recovery (STIR), turbo-spin-echo (TSE)-T2 sequences, a pre-contrast T1, and a single intermediate (3 minutes after contrast injection) post-contrast T1 sequence for characterizing breast lesions. A total of 470 patients underwent breast MR examination for screening, problem solving, or preoperative staging. Two experienced radiologists evaluated both standard and abbreviated protocols in consensus. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy for both protocols were calculated (with the histological findings and 6-month ultrasound follow-up as the reference standard) and compared with the McNemar test. The post-processing and interpretation times for the MR images were compared with the paired t test. In 177 of 470 (38%) patients, the MR sequences detected 185 breast lesions. Standard and abbreviated protocols obtained sensitivity, specificity, diagnostic accuracy, PPV, and NPV values respectively of 92%, 92%, 92%, 68%, and 98% and of 89%, 91%, 91%, 64%, and 98% with no statistically significant difference (P < .0001). The mean post-processing and interpretation time were, respectively, 7 ± 1 minutes and 6 ± 3.2 minutes for the standard protocol and 1 ± 1.2 minutes and 2 ± 1.2 minutes for the abbreviated protocol, with a statistically significant difference (P < .01). An abbreviated combined MR protocol represents a time-saving tool for radiologists and patients with the same diagnostic potential as the standard protocol in patients undergoing breast MRI for screening, problem solving, or preoperative staging. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Titrating Oxygen Requirements During Exercise: Evaluation of a Standardized Single Walk Test Protocol.

    PubMed

    Giovacchini, Coral X; Mathews, Anne M; Lawlor, Brian R; MacIntyre, Neil R

    2018-04-01

    Oxygen supplementation for exercise-induced hypoxemia is a common clinical practice that improves exercise tolerance. However, we know of no standardized exercise oxygen titration protocol using a single walk test. We report our experience with a protocol developed in our laboratory. Our protocol is based on the 6-min walk test (6MWT). Pulse oximetry readings (oxygen saturation [Spo 2 ]) are monitored, and supplemental oxygen is added in 2 L/min increments to keep Spo 2 > 88%. This continues for at least 6 min of walking with the Spo 2 remaining > 88% for at least 3 min. The records of consecutive patients over 4 months undergoing this procedure were reviewed for test performance, oxygen titration results, and adverse events. Two hundred twenty-two patients were tested; only two prematurely terminated the protocol because of intractable dyspnea. One hundred fifty-six patients (38%) required oxygen supplementation, with the first titration most commonly occurring between 1 and 2 min of walking. Nine of the patients had the first titration after 5 min of walking. The average test duration was 7 min (maximum, 15 min). The average number of titrations was 2.2 (maximum six). Sixteen patients could not maintain Spo 2 > 88% for 3 min despite administration of 15 L/min of supplemental oxygen (maximal dose). Our protocol was easily performed as a modification of a standard 6MWT with no serious adverse events. Because it is based on a widely accepted measurement of functional capabilities, and because it determined a stable final oxygen dose for ≥ 3 min of walking in most patients, we believe this protocol can be easily adapted for clinical use. Copyright © 2017 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  8. 42 CFR 493.1278 - Standard: Histocompatibility.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... screening, compatibility testing and crossmatching) to be performed for each type of cell, tissue or organ... protocols for cadaver donor, living, living-related, and combined organ and tissue transplants; (ii) Testing protocols for patients at high risk for allograft rejection; and (iii) The level of testing required to...

  9. 42 CFR 493.1278 - Standard: Histocompatibility.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... screening, compatibility testing and crossmatching) to be performed for each type of cell, tissue or organ... protocols for cadaver donor, living, living-related, and combined organ and tissue transplants; (ii) Testing protocols for patients at high risk for allograft rejection; and (iii) The level of testing required to...

  10. 16 CFR 1210.4 - Test protocol.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... live within the United States. (4) The age and sex distribution of each 100-child panel shall be: (i... recorded for each child in the 100-child test panel: (1) Sex (male or female). (2) Date of birth (month... STANDARD FOR CIGARETTE LIGHTERS Requirements for Child Resistance § 1210.4 Test protocol. (a) Child test...

  11. 16 CFR § 1212.4 - Test protocol.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...) The children for the test panel shall live within the United States. (4) The age and sex distribution... child in the 100-child test panel: (1) Sex (male or female). (2) Date of birth (month, day, year). (3... STANDARD FOR MULTI-PURPOSE LIGHTERS Requirements for Child-Resistance § 1212.4 Test protocol. (a) Child...

  12. 16 CFR 1210.4 - Test protocol.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... live within the United States. (4) The age and sex distribution of each 100-child panel shall be: (i... recorded for each child in the 100-child test panel: (1) Sex (male or female). (2) Date of birth (month... STANDARD FOR CIGARETTE LIGHTERS Requirements for Child Resistance § 1210.4 Test protocol. (a) Child test...

  13. 16 CFR 1212.4 - Test protocol.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ...) The children for the test panel shall live within the United States. (4) The age and sex distribution... child in the 100-child test panel: (1) Sex (male or female). (2) Date of birth (month, day, year). (3... STANDARD FOR MULTI-PURPOSE LIGHTERS Requirements for Child-Resistance § 1212.4 Test protocol. (a) Child...

  14. 16 CFR § 1210.4 - Test protocol.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... live within the United States. (4) The age and sex distribution of each 100-child panel shall be: (i... recorded for each child in the 100-child test panel: (1) Sex (male or female). (2) Date of birth (month... STANDARD FOR CIGARETTE LIGHTERS Requirements for Child Resistance § 1210.4 Test protocol. (a) Child test...

  15. 16 CFR 1212.4 - Test protocol.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ...) The children for the test panel shall live within the United States. (4) The age and sex distribution... child in the 100-child test panel: (1) Sex (male or female). (2) Date of birth (month, day, year). (3... STANDARD FOR MULTI-PURPOSE LIGHTERS Requirements for Child-Resistance § 1212.4 Test protocol. (a) Child...

  16. Comparison of Bruce treadmill exercise test protocols: is ramped Bruce equal or superior to standard bruce in producing clinically valid studies for patients presenting for evaluation of cardiac ischemia or arrhythmia with body mass index equal to or greater than 30?

    PubMed

    Bires, Angela Macci; Lawson, Dori; Wasser, Thomas E; Raber-Baer, Donna

    2013-12-01

    Clinically valid cardiac evaluation via treadmill stress testing requires patients to achieve specific target heart rates and to successfully complete the cardiac examination. A comparison of the standard Bruce protocol and the ramped Bruce protocol was performed using data collected over a 1-y period from a targeted patient population with a body mass index (BMI) equal to or greater than 30 to determine which treadmill protocol provided more successful examination results. The functional capacity, metabolic equivalent units achieved, pressure rate product, and total time on the treadmill as measured for the obese patients were clinically valid and comparable to normal-weight and overweight patients (P < 0.001). Data gathered from each protocol demonstrated that the usage of the ramped Bruce protocol achieved more consistent results in comparison across all BMI groups in achieving 80%-85% of their age-predicted maximum heart rate. This study did not adequately establish that the ramped Bruce protocol was superior to the standard Bruce protocol for the examination of patients with a BMI equal to or greater than 30.

  17. TCP Performance Enhancement Over Iridium

    NASA Technical Reports Server (NTRS)

    Torgerson, Leigh; Hutcherson, Joseph; McKelvey, James

    2007-01-01

    In support of iNET maturation, NASA-JPL has collaborated with NASA-Dryden to develop, test and demonstrate an over-the-horizon vehicle-to-ground networking capability, using Iridium as the vehicle-to-ground communications link for relaying critical vehicle telemetry. To ensure reliability concerns are met, the Space Communications Protocol Standards (SCPS) transport protocol was investigated for its performance characteristics in this environment. In particular, the SCPS-TP software performance was compared to that of the standard Transmission Control Protocol (TCP) over the Internet Protocol (IP). This paper will report on the results of this work.

  18. NASA's Plan for SDLS Testing

    NASA Technical Reports Server (NTRS)

    Bailey, Brandon

    2015-01-01

    The Space Data Link Security (SDLS) Protocol is a Consultative Committee for Space Data Systems (CCSDS) standard which extends the known Data Link protocols to secure data being sent over a space link by providing confidentiality and integrity services. This plan outlines the approach by National Aeronautics Space Administration (NASA) in performing testing of the SDLS protocol using a prototype based on an existing NASA missions simulator.

  19. A Survey Examining Photopatch Test and Phototest Methodologies of Contact Dermatologists in the United States: Platform for Developing A Consensus.

    PubMed

    Asemota, Eseosa; Crawford, Glen; Kovarik, Carrie; Brod, Bruce A

    There is currently no standardized protocol for photopatch testing and phototesting in the United States. Certain testing paramaters (such as chemicals tested, time between test application and irradiation, and time of final interpretation) vary from provider to provider. These variations may impact comparability and consistency of test results. The goal of our survey-based study was to outline the photopatch test and phototest protocols used by US contact dermatologists. The information obtained will aid in the development of a national consensus on testing methodologies. Based on a literature search conducted on differences in testing methodologies, we constructed a questionnaire. The survey was distributed at the American Contact Dermatitis Society annual meeting and via the American Contact Dermatitis Society Web site. Standard descriptive analysis was performed on data obtained. Of the 800 dermatologists contacted, 117 agreed to participate in the survey. Among these respondents, 64 (54.8%) conduct photopatch testing. Results of the survey are presented, and they confirm that a variety of techniques and testing materials are used. It would be beneficial to enlist a panel of expert contact dermatologists to create by formal consensus, using these research findings, a standard photopatch test protocol for use in this country.

  20. Evaluation of platelet adhesion and activation on polymers: Round-robin study to assess inter-center variability.

    PubMed

    Braune, S; Sperling, C; Maitz, M F; Steinseifer, U; Clauser, J; Hiebl, B; Krajewski, S; Wendel, H P; Jung, F

    2017-10-01

    The regulatory agencies provide recommendations rather than protocols or standard operation procedures for the hemocompatibility evaluation of novel materials e.g. for cardiovascular applications. Thus, there is a lack of specifications with regard to test setups and procedures. As a consequence, laboratories worldwide perform in vitro assays under substantially different test conditions, so that inter-laboratory and inter-study comparisons are impossible. Here, we report about a prospective, randomized and double-blind multicenter trial which demonstrates that standardization of in vitro test protocols allows a reproducible assessment of platelet adhesion and activation from fresh human platelet rich plasma as possible indicators of the thrombogenicity of cardiovascular implants. Standardization of the reported static in vitro setup resulted in a laboratory independent scoring of the following materials: poly(dimethyl siloxane) (PDMS), poly(ethylene terephthalate) (PET) and poly(tetrafluoro ethylene) (PTFE). The results of this in vitro study provide evidence that inter-laboratory and inter-study comparisons can be achieved for the evaluation of the adhesion and activation of platelets on blood-contacting biomaterials by stringent standardization of test protocols. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Development, implementation, and experimentation of parametric routing protocol for sensor networks

    NASA Astrophysics Data System (ADS)

    Nassr, Matthew S.; Jun, Jangeun; Eidenbenz, Stephan J.; Frigo, Janette R.; Hansson, Anders A.; Mielke, Angela M.; Smith, Mark C.

    2006-09-01

    The development of a scalable and reliable routing protocol for sensor networks is traced from a theoretical beginning to positive simulation results to the end of verification experiments in large and heavily loaded networks. Design decisions and explanations as well as implementation hurdles are presented to give a complete picture of protocol development. Additional software and hardware is required to accurately test the performance of our protocol in field experiments. In addition, the developed protocol is tested in TinyOS on Mica2 motes against well-established routing protocols frequently used in sensor networks. Our protocol proves to outperform the standard (MINTRoute) and the trivial (Gossip) in a variety of different scenarios.

  2. Validity of linear measurements of the jaws using ultralow-dose MDCT and the iterative techniques of ASIR and MBIR.

    PubMed

    Al-Ekrish, Asma'a A; Al-Shawaf, Reema; Schullian, Peter; Al-Sadhan, Ra'ed; Hörmann, Romed; Widmann, Gerlig

    2016-10-01

    To assess the comparability of linear measurements of dental implant sites recorded from multidetector computed tomography (MDCT) images obtained using standard-dose filtered backprojection (FBP) technique with those from various ultralow doses combined with FBP, adaptive statistical iterative reconstruction (ASIR), and model-based iterative reconstruction (MBIR) techniques. The results of the study may contribute to MDCT dose optimization for dental implant site imaging. MDCT scans of two cadavers were acquired using a standard reference protocol and four ultralow-dose test protocols (TP). The volume CT dose index of the different dose protocols ranged from a maximum of 30.48-36.71 mGy to a minimum of 0.44-0.53 mGy. All scans were reconstructed using FBP, ASIR-50, ASIR-100, and MBIR, and either a bone or standard reconstruction kernel. Linear measurements were recorded from standardized images of the jaws by two examiners. Intra- and inter-examiner reliability of the measurements were analyzed using Cronbach's alpha and inter-item correlation. Agreement between the measurements obtained with the reference-dose/FBP protocol and each of the test protocols was determined with Bland-Altman plots and linear regression. Statistical significance was set at a P-value of 0.05. No systematic variation was found between the linear measurements obtained with the reference protocol and the other imaging protocols. The only exceptions were TP3/ASIR-50 (bone kernel) and TP4/ASIR-100 (bone and standard kernels). The mean measurement differences between these three protocols and the reference protocol were within ±0.1 mm, with the 95 % confidence interval limits being within the range of ±1.15 mm. A nearly 97.5 % reduction in dose did not significantly affect the height and width measurements of edentulous jaws regardless of the reconstruction algorithm used.

  3. Technical standards and guidelines: prenatal screening for Down syndrome that includes first-trimester biochemistry and/or ultrasound measurements.

    PubMed

    Palomaki, Glenn E; Lee, Jo Ellen S; Canick, Jacob A; McDowell, Geraldine A; Donnenfeld, Alan E

    2009-09-01

    This statement is intended to augment the current general ACMG Standards and Guidelines for Clinical Genetics Laboratories and to address guidelines specific to first-trimester screening for Down syndrome. The aim is to provide the laboratory the necessary information to ensure accurate and reliable Down syndrome screening results given a screening protocol (e.g., combined first trimester and integrated testing). Information about various test combinations and their expected performance are provided, but other issues such as availability of reagents, patient interest in early test results, access to open neural tube defect screening, and availability of chorionic villus sampling are all contextual factors in deciding which screening protocol(s) will be selected by individual health care providers. Individual laboratories are responsible for meeting the quality assurance standards described by the Clinical Laboratory Improvement Act, the College of American Pathologists, and other regulatory agencies, with respect to appropriate sample documentation, assay validation, general proficiency, and quality control measures. These guidelines address first-trimester screening that includes ultrasound measurement and interpretation of nuchal translucency thickness and protocols that combine markers from both the first and second trimesters. Laboratories can use their professional judgment to make modification or additions.

  4. 40 CFR 721.4472 - Phenyl, alkyl, hydroxyalkyl substituted imidazole (generic).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... percent), and (c). (ii) Hazard communication program. Requirements as specified in § 721.72 (a), (b), (c... protocol. (3) TSCA Good Laboratory Practice Standards at 40 CFR part 792. (4) Using methodologies generally..., the person must obtain approval of test protocols from EPA by submitting written protocols. EPA will...

  5. 42 CFR 493.1251 - Standard: Procedure manual.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS Quality System for Nonwaived Testing Analytic... intervals (normal values). (11) Imminently life-threatening test results, or panic or alert values. (12... reporting patient results including, when appropriate, the protocol for reporting imminently life...

  6. 42 CFR 493.1251 - Standard: Procedure manual.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS Quality System for Nonwaived Testing Analytic... intervals (normal values). (11) Imminently life-threatening test results, or panic or alert values. (12... reporting patient results including, when appropriate, the protocol for reporting imminently life...

  7. 42 CFR 493.1251 - Standard: Procedure manual.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS Quality System for Nonwaived Testing Analytic... intervals (normal values). (11) Imminently life-threatening test results, or panic or alert values. (12... reporting patient results including, when appropriate, the protocol for reporting imminently life...

  8. Assessment of Protocol Designed to Detect Endocine Disrupting Effects of Flutamide in Xenopus Tropicalis

    DTIC Science & Technology

    2006-01-01

    Environmental Protection Agency (USEPA) Endocrine Disruptor Screening and Testing Program. The frogs were exposed to the model anti- androgenic...the study were to develop a protocol that could be used for a standard U.S. EPA testing procedure in the Endocrine Disruptor Screening and Testing...compounds. As a consequence of this requirement, the USEPA established an Endocrine Disruptor Screening and Testing Advisory Committee (EDSTAC

  9. Defining standardized protocols for determining the efficacy of a postmilking teat disinfectant following experimental exposure of teats to mastitis pathogens.

    PubMed

    Schukken, Y H; Rauch, B J; Morelli, J

    2013-04-01

    The objective of this paper was to define standardized protocols for determining the efficacy of a postmilking teat disinfectant following experimental exposure of teats to both Staphylococcus aureus and Streptococcus agalactiae. The standardized protocols describe the selection of cows and herds and define the critical points in performing experimental exposure, performing bacterial culture, evaluating the culture results, and finally performing statistical analyses and reporting of the results. The protocols define both negative control and positive control trials. For negative control trials, the protocol states that an efficacy of reducing new intramammary infections (IMI) of at least 40% is required for a teat disinfectant to be considered effective. For positive control trials, noninferiority to a control disinfectant with a published efficacy of reducing new IMI of at least 70% is required. Sample sizes for both negative and positive control trials are calculated. Positive control trials are expected to require a large trial size. Statistical analysis methods are defined and, in the proposed methods, the rate of IMI may be analyzed using generalized linear mixed models. The efficacy of the test product can be evaluated while controlling for important covariates and confounders in the trial. Finally, standards for reporting are defined and reporting considerations are discussed. The use of the defined protocol is shown through presentation of the results of a recent trial of a test product against a negative control. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  10. Evaluation of hemifield sector analysis protocol in multifocal visual evoked potential objective perimetry for the diagnosis and early detection of glaucomatous field defects.

    PubMed

    Mousa, Mohammad F; Cubbidge, Robert P; Al-Mansouri, Fatima; Bener, Abdulbari

    2014-02-01

    Multifocal visual evoked potential (mfVEP) is a newly introduced method used for objective visual field assessment. Several analysis protocols have been tested to identify early visual field losses in glaucoma patients using the mfVEP technique, some were successful in detection of field defects, which were comparable to the standard automated perimetry (SAP) visual field assessment, and others were not very informative and needed more adjustment and research work. In this study we implemented a novel analysis approach and evaluated its validity and whether it could be used effectively for early detection of visual field defects in glaucoma. Three groups were tested in this study; normal controls (38 eyes), glaucoma patients (36 eyes) and glaucoma suspect patients (38 eyes). All subjects had a two standard Humphrey field analyzer (HFA) test 24-2 and a single mfVEP test undertaken in one session. Analysis of the mfVEP results was done using the new analysis protocol; the hemifield sector analysis (HSA) protocol. Analysis of the HFA was done using the standard grading system. Analysis of mfVEP results showed that there was a statistically significant difference between the three groups in the mean signal to noise ratio (ANOVA test, p < 0.001 with a 95% confidence interval). The difference between superior and inferior hemispheres in all subjects were statistically significant in the glaucoma patient group in all 11 sectors (t-test, p < 0.001), partially significant in 5 / 11 (t-test, p < 0.01), and no statistical difference in most sectors of the normal group (1 / 11 sectors was significant, t-test, p < 0.9). Sensitivity and specificity of the HSA protocol in detecting glaucoma was 97% and 86%, respectively, and for glaucoma suspect patients the values were 89% and 79%, respectively. The new HSA protocol used in the mfVEP testing can be applied to detect glaucomatous visual field defects in both glaucoma and glaucoma suspect patients. Using this protocol can provide information about focal visual field differences across the horizontal midline, which can be utilized to differentiate between glaucoma and normal subjects. Sensitivity and specificity of the mfVEP test showed very promising results and correlated with other anatomical changes in glaucoma field loss.

  11. Evaluation of Hemifield Sector Analysis Protocol in Multifocal Visual Evoked Potential Objective Perimetry for the Diagnosis and Early Detection of Glaucomatous Field Defects

    PubMed Central

    Mousa, Mohammad F.; Cubbidge, Robert P.; Al-Mansouri, Fatima

    2014-01-01

    Purpose Multifocal visual evoked potential (mfVEP) is a newly introduced method used for objective visual field assessment. Several analysis protocols have been tested to identify early visual field losses in glaucoma patients using the mfVEP technique, some were successful in detection of field defects, which were comparable to the standard automated perimetry (SAP) visual field assessment, and others were not very informative and needed more adjustment and research work. In this study we implemented a novel analysis approach and evaluated its validity and whether it could be used effectively for early detection of visual field defects in glaucoma. Methods Three groups were tested in this study; normal controls (38 eyes), glaucoma patients (36 eyes) and glaucoma suspect patients (38 eyes). All subjects had a two standard Humphrey field analyzer (HFA) test 24-2 and a single mfVEP test undertaken in one session. Analysis of the mfVEP results was done using the new analysis protocol; the hemifield sector analysis (HSA) protocol. Analysis of the HFA was done using the standard grading system. Results Analysis of mfVEP results showed that there was a statistically significant difference between the three groups in the mean signal to noise ratio (ANOVA test, p < 0.001 with a 95% confidence interval). The difference between superior and inferior hemispheres in all subjects were statistically significant in the glaucoma patient group in all 11 sectors (t-test, p < 0.001), partially significant in 5 / 11 (t-test, p < 0.01), and no statistical difference in most sectors of the normal group (1 / 11 sectors was significant, t-test, p < 0.9). Sensitivity and specificity of the HSA protocol in detecting glaucoma was 97% and 86%, respectively, and for glaucoma suspect patients the values were 89% and 79%, respectively. Conclusions The new HSA protocol used in the mfVEP testing can be applied to detect glaucomatous visual field defects in both glaucoma and glaucoma suspect patients. Using this protocol can provide information about focal visual field differences across the horizontal midline, which can be utilized to differentiate between glaucoma and normal subjects. Sensitivity and specificity of the mfVEP test showed very promising results and correlated with other anatomical changes in glaucoma field loss. PMID:24511212

  12. A rapid reversed-phase thin layer chromatographic protocol for detection of adulteration in ghee (clarified milk fat) with vegetable oils.

    PubMed

    Rani, Anupama; Sharma, Vivek; Arora, Sumit; Lal, Darshan; Kumar, Anil

    2015-04-01

    Detection of milk fat adulteration with foreign fats/oils continues to be a challenge for the dairy industry as well as food testing laboratories, especially in the present scenario of rampant adulteration using the scientific knowledge by unscrupulous persons involved in the trade. In the present investigation a rapid reversed-phase thin layer chromatographic (RP-TLC) protocol was standardized to ascertain the purity of milk fat. RP-TLC protocol did not show any false positive results in the genuine ghee (clarified butter fat) samples of known origin. Adulteration of ghee with coconut oil up to 7. 5 %, soybean oil, sunflower oil and groundnut oil up to 1 %, while, designer oil up to 2 % level could be detected using the standardized RP-TLC protocol. The protocol standardized is rapid and convenient to use.

  13. Motion Imagery and Robotics Application (MIRA)

    NASA Technical Reports Server (NTRS)

    Martinez, Lindolfo; Rich, Thomas

    2011-01-01

    Objectives include: I. Prototype a camera service leveraging the CCSDS Integrated protocol stack (MIRA/SM&C/AMS/DTN): a) CCSDS MIRA Service (New). b) Spacecraft Monitor and Control (SM&C). c) Asynchronous Messaging Service (AMS). d) Delay/Disruption Tolerant Networking (DTN). II. Additional MIRA Objectives: a) Demo of Camera Control through ISS using CCSDS protocol stack (Berlin, May 2011). b) Verify that the CCSDS standards stack can provide end-to-end space camera services across ground and space environments. c) Test interoperability of various CCSDS protocol standards. d) Identify overlaps in the design and implementations of the CCSDS protocol standards. e) Identify software incompatibilities in the CCSDS stack interfaces. f) Provide redlines to the SM&C, AMS, and DTN working groups. d) Enable the CCSDS MIRA service for potential use in ISS Kibo camera commanding. e) Assist in long-term evolution of this entire group of CCSDS standards to TRL 6 or greater.

  14. Improving the Sandia Test Protocols with Advanced Inverter Functionality Testing of INV3, VV11, FW21, and L/HVRT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, Jay Dean

    2013-11-01

    Sandia National Laboratories has created a test protocol for IEC TR 61850-90-7 advanced distributed energy resource (DER) functions, titled "Test Protocols for Advanced Inverter Interoperability Functions," often referred to as the Sandia Test Protocols. This document is currently in draft form, but has been shared with stakeholders around the world with the ultimate goal of collaborating to create a consensus set of test protocols which can be then incorporated into an International Electrotechnical Commission (IEC) and/or Underwriters Laboratories (UL) certification standard. The protocols are designed to ensure functional interoperability of DER (primarily photovoltaic (PV) inverters and energy storage systems) asmore » specified by the IEC technical report through communication and electrical tests. In this report, Sandia exercises the electrical characterization portion of the test protocols for four functions: constant power factor (INV3), volt-var (VV11), frequency-watt (FW21), and Low and High Voltage Ride Through (L/HVRT). The goal of the tests reported here was not to characterize the performance of the equipment under test (EUT), but rather to (a) exercise the draft Sandia Test Protocols in order to identify any revisions needed in test procedures, conditions, or equipment and (b) gain experience with state-of-the-art DER equipment to determine if the tests put unrealistic or overly aggressive requirements on EUT operation. In performing the work according to the current versions of the protocols, Sandia was able to identify weaknesses in the current versions and suggest improvements to the test protocols.« less

  15. An Evaluation of Protocol Enhancing Proxies and File Transport Protocols for Satellite Communication

    NASA Technical Reports Server (NTRS)

    Finch, Patrick Eugene; Sullivan, Donald; Ivancic, William D.

    2012-01-01

    NASA is utilizing Global Hawk aircraft in high-altitude, long-duration Earth science missions. Communications with the onboard research equipment and sensors (the science payload) is via Ku-Band radio utilizing satellites in geostationary orbits. All payload communications use standard Internet Protocols and routing, and much of the data to be transferred is comprised of very large files. The science community is interested in fully utilizing these communication links to retrieve data as quickly and reliably as possible. A test bed was developed at NASA Ames to evaluate modern transport protocols as well as Protocol Enhancing Proxies (PEPs) to determine what tools best fit the needs of the science community. This paper describes the test bed used, the protocols, the PEPs that were evaluated, the particular tests performed and the results and conclusions.

  16. Reliability and Accuracy of a Standardized Shallow Water Running Test to Determine Cardiorespiratory Fitness.

    PubMed

    Nagle, Elizabeth F; Sanders, Mary E; Gibbs, Bethany B; Franklin, Barry A; Nagle, Jacquelyn A; Prins, Philip J; Johnson, Caleb D; Robertson, Robert J

    2017-06-01

    A standardized fitness assessment is critical for the development of an individualized exercise prescription. Although the benefits of aquatic exercise have been well established, there remains the need for a standardized nonswimming protocol to accurately assess cardiorespiratory fitness (CRF) in shallow water. The present investigation was designed to assess (a) the reliability of a standardized shallow water run (SWR) test of CRF and (b) the accuracy of a standardized SWR compared with a land-based treadmill (LTM) test. Twenty-three healthy women (20 ± 3 years), with body mass index (23.5 ± 3 kg·m), performed 2 shallow water peak oxygen consumption (V[Combining Dot Above]O2peak) running tests (SWRa and SWRb), and 1 V[Combining Dot Above]O2max LTM. Intraclass correlation coefficients indicated moderately strong reliability for V[Combining Dot Above]O2peak (ml·kg·min) (r = 0.73, p < 0.01), HRpeak (b·min) (r = 0.82; p < 0.01), and O2pulse (V[Combining Dot Above]O2 [ml·kg·min]·HR [b·min]) (r = 0.77, p < 0.01). Using paired t-tests and Pearson's correlations, SWR V[Combining Dot Above]O2peak and HRpeak were significantly lower than during LTM (p ≤ 0.05) and showed moderate correlations of 0.60 and 0.58 (p < 0.001) to LTM. O2pulse was similar (p > 0.05) for the SWR and LTM tests with a moderate correlation of 0.63. A standardized SWR test as a measure of CRF is a reliable, and to some degree, valid alternative to conventional protocols and may be used by strength and conditioning professionals to measure program outcomes and monitor training progress. Furthermore, this protocol provides a water-based option for CRF assessment among healthy women and offers insight toward the development of an effective protocol that can accommodate individuals with limited mobility, or those seeking less musculoskeletal impact from traditional land-based types of training.

  17. Development of Uniform Protocol for Alopecia Areata Clinical Trials.

    PubMed

    Solomon, James A

    2015-11-01

    Developing a successful treatment for alopecia areata (AA), clearly has not been at the forefront of the agenda for new drug/device development among the pharmaceutical and medical device industry. The National Alopecia Areata Foundation (NAAF), a patient advocacy group, initiated a plan to facilitate and drive clinical research toward finding safe and efficacious treatments for AA. As such, Alopecia Areata Uniform Protocols for clinical trials to test new treatments for AA were developed. The design of the uniform protocol is to accomplish the development of a plug-and-play template as well as to provide a framework wherein data from studies utilizing the uniform protocol can be compared through consistency of inclusions/exclusions, safety, and outcome assessment measures. A core uniform protocol for use by pharmaceutical companies in testing proof of concept for investigational products to treat AA. The core protocol includes standardized title, informed consent, inclusion/exclusion criteria, disease outcome assessments, and safety assessments. The statistical methodology to assess successful outcomes will also be standardized. The protocol as well as the informed consent form has been approved in concept by Liberty IRB and is ready to present to pharmaceutical companies.

  18. NASA'S Standard Measures During Bed Rest: Adaptations in the Cardiovascular System

    NASA Technical Reports Server (NTRS)

    Lee, Stuart M. C.; Feiveson, Alan H.; Martin, David S.; Cromwell, Roni L.; Platts, Steven H.; Stenger, Michael B.

    2016-01-01

    Bed rest is a well-accepted analog of space flight that has been used extensively to investigate physiological adaptations in a larger number of subjects in a shorter amount of time than can be studied with space flight and without the confounding effects associated with normal mission operations. However, comparison across studies of different bed rest durations, between sexes, and between various countermeasure protocols have been hampered by dissimilarities in bed rest conditions, measurement protocols, and testing schedules. To address these concerns, NASA instituted standard bed rest conditions and standard measures for all physiological disciplines participating in studies conducted at the Flight Analogs Research Unit (FARU) at the University of Texas-Medical Branch. Investigators for individual studies employed their own targeted study protocols to address specific hypothesis-driven questions, but standard measures tests were conducted within these studies on a non-interference basis to maximize data availability while reducing the need to implement multiple bed rest studies to understand the effects of a specific countermeasure. When possible, bed rest standard measures protocols were similar to tests nominally used for medically-required measures or research protocols conducted before and after Space Shuttle and International Space Station missions. Specifically, bed rest standard measures for the cardiovascular system implemented before, during, and after bed rest at the FARU included plasma volume (carbon monoxide rebreathing), cardiac mass and function (2D, 3D and Doppler echocardiography), and orthostatic tolerance testing (15- or 30-minutes of 80 degree head-up tilt). Results to-date indicate that when countermeasures are not employed, plasma volume decreases and the incidence of presyncope during head-up tilt is more frequent even after short-duration bed rest while reductions in cardiac function and mass are progressive as bed rest duration increases. Additionally, while plasma volume loss can be corrected and cardiac mass can be prevented with properly applied countermeasures, orthostatic tolerance is more difficult to protect when supine exercise is the only countermeasure. Similar results have been observed after space flight. Plasma volume, cardiac chamber volume, and orthostatic tolerance recover relatively quickly with resumption of ambulation and normal activity levels after bed rest but restoration of cardiac mass is prolonged.

  19. Sizing Single Cantilever Beam Specimens for Characterizing Facesheet/Core Peel Debonding in Sandwich Structure

    NASA Technical Reports Server (NTRS)

    Ratcliffe, James G.

    2010-01-01

    This technical publication details part of an effort focused on the development of a standardized facesheet/core peel debonding test procedure. The purpose of the test is to characterize facesheet/core peel in sandwich structure, accomplished through the measurement of the critical strain energy release rate associated with the debonding process. Following an examination of previously developed tests and a recent evaluation of a selection of these methods, a single cantilever beam (SCB) specimen was identified as being a promising candidate for establishing such a standardized test procedure. The objective of the work described here was to begin development of a protocol for conducting a SCB test that will render the procedure suitable for standardization. To this end, a sizing methodology was developed to ensure appropriate SCB specimen dimensions are selected for a given sandwich system. Application of this method to actual sandwich systems yielded SCB specimen dimensions that would be practical for use. This study resulted in the development of a practical SCB specimen sizing method, which should be well-suited for incorporation into a standardized testing protocol.

  20. 40 CFR 157.32 - Standards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... REQUIREMENTS FOR PESTICIDES AND DEVICES Child-Resistant Packaging § 157.32 Standards. (a) Effectiveness standard. The child-resistant packaging, when tested by the protocol specified in 16 CFR 1700.20, shall meet the effectiveness specifications in 16 CFR 1700.15(b). (b) Compatibility standard. The child...

  1. SLOWLY REPEATED EVOKED PAIN (SREP) AS A MARKER OF CENTRAL SENSITIZATION IN FIBROMYALGIA: DIAGNOSTIC ACCURACY AND RELIABILITY IN COMPARISON WITH TEMPORAL SUMMATION OF PAIN.

    PubMed

    de la Coba, Pablo; Bruehl, Stephen; Gálvez-Sánchez, Carmen María; Reyes Del Paso, Gustavo A

    2018-05-01

    This study examined the diagnostic accuracy and test-retest reliability of a novel dynamic evoked pain protocol (slowly repeated evoked pain; SREP) compared to temporal summation of pain (TSP), a standard index of central sensitization. Thirty-five fibromyalgia (FM) and 30 rheumatoid arthritis (RA) patients completed, in pseudorandomized order, a standard mechanical TSP protocol (10 stimuli of 1s duration at the thenar eminence using a 300g monofilament with 1s interstimulus interval) and the SREP protocol (9 suprathreshold pressure stimuli of 5s duration applied to the fingernail with a 30s interstimulus interval). In order to evaluate reliability for both protocols, they were repeated in a second session 4-7 days later. Evidence for significant pain sensitization over trials (increasing pain intensity ratings) was observed for SREP in FM (p<.001) but not in RA (p=.35), whereas significant sensitization was observed in both diagnostic groups for the TSP protocol (p's<.008). Compared to TSP, SREP demonstrated higher overall diagnostic accuracy (87.7% vs. 64.6%), greater sensitivity (0.89 vs. 0.57), and greater specificity (0.87 vs. 0.73) in discriminating between FM and RA patients. Test-retest reliability of SREP sensitization was good in FM (ICCs: 0.80), and moderate in RA (ICC: 0.68). SREP seems to be a dynamic evoked pain index tapping into pain sensitization that allows for greater diagnostic accuracy in identifying FM patients compared to a standard TSP protocol. Further research is needed to study mechanisms underlying SREP and the potential utility of adding SREP to standard pain evaluation protocols.

  2. Development of FWD procedures manual.

    DOT National Transportation Integrated Search

    2010-04-01

    In this project, the state-of-practice in FWD testing and analysis procedures were examined : by looking at the standard protocols of a number of other highway agencies. The specific : needs of NJDOT were also examined and a protocol was developed th...

  3. State Summary of Soil and Groundwater Cleanup Standards for Hydrocarbons

    DTIC Science & Technology

    1993-11-15

    821096-01 November 15, 1993 19970425 057 !DISTfRIBUTI STýA-TEM,_ Approved for public release; Distribution Unlbfited Product - Paranmeter/ Lab Test ...Env-mmenal Mantagemen, 20-270-5613 Product Parameter/ Lab Test Protocol Detection Notification Action Clean-up Level Constituent & Number Level Level...Envi-mnentai Managament, 205-270-.5613 Su m r of Alsk Clanu Sadr s fo Hyrcro Cotmiae Groundwater Product- - Parameter/ Lab Test Protocol ’Detection

  4. Improving language mapping in clinical fMRI through assessment of grammar.

    PubMed

    Połczyńska, Monika; Japardi, Kevin; Curtiss, Susan; Moody, Teena; Benjamin, Christopher; Cho, Andrew; Vigil, Celia; Kuhn, Taylor; Jones, Michael; Bookheimer, Susan

    2017-01-01

    Brain surgery in the language dominant hemisphere remains challenging due to unintended post-surgical language deficits, despite using pre-surgical functional magnetic resonance (fMRI) and intraoperative cortical stimulation. Moreover, patients are often recommended not to undergo surgery if the accompanying risk to language appears to be too high. While standard fMRI language mapping protocols may have relatively good predictive value at the group level, they remain sub-optimal on an individual level. The standard tests used typically assess lexico-semantic aspects of language, and they do not accurately reflect the complexity of language either in comprehension or production at the sentence level. Among patients who had left hemisphere language dominance we assessed which tests are best at activating language areas in the brain. We compared grammar tests (items testing word order in actives and passives, wh -subject and object questions, relativized subject and object clauses and past tense marking) with standard tests (object naming, auditory and visual responsive naming), using pre-operative fMRI. Twenty-five surgical candidates (13 females) participated in this study. Sixteen patients presented with a brain tumor, and nine with epilepsy. All participants underwent two pre-operative fMRI protocols: one including CYCLE-N grammar tests (items testing word order in actives and passives, wh-subject and object questions, relativized subject and object clauses and past tense marking); and a second one with standard fMRI tests (object naming, auditory and visual responsive naming). fMRI activations during performance in both protocols were compared at the group level, as well as in individual candidates. The grammar tests generated more volume of activation in the left hemisphere (left/right angular gyrus, right anterior/posterior superior temporal gyrus) and identified additional language regions not shown by the standard tests (e.g., left anterior/posterior supramarginal gyrus). The standard tests produced more activation in left BA 47. Ten participants had more robust activations in the left hemisphere in the grammar tests and two in the standard tests. The grammar tests also elicited substantial activations in the right hemisphere and thus turned out to be superior at identifying both right and left hemisphere contribution to language processing. The grammar tests may be an important addition to the standard pre-operative fMRI testing.

  5. Evaluation of Dogs with Border Collie Collapse, Including Response to Two Standardized Strenuous Exercise Protocols.

    PubMed

    Taylor, Susan; Shmon, Cindy; Su, Lillian; Epp, Tasha; Minor, Katie; Mickelson, James; Patterson, Edward; Shelton, G Diane

    2016-01-01

    Clinical and metabolic variables were evaluated in 13 dogs with border collie collapse (BCC) before, during, and following completion of standardized strenuous exercise protocols. Six dogs participated in a ball-retrieving protocol, and seven dogs participated in a sheep-herding protocol. Findings were compared with 16 normal border collies participating in the same exercise protocols (11 retrieving, five herding). Twelve dogs with BCC developed abnormal mentation and/or an abnormal gait during evaluation. All dogs had post-exercise elevations in rectal temperature, pulse rate, arterial blood pH, PaO2, and lactate, and decreased PaCO2 and bicarbonate, as expected with strenuous exercise, but there were no significant differences between BCC dogs and normal dogs. Electrocardiography demonstrated sinus tachycardia in all dogs following exercise. Needle electromyography was normal, and evaluation of muscle biopsy cryosections using a standard panel of histochemical stains and reactions did not reveal a reason for collapse in 10 dogs with BCC in which these tests were performed. Genetic testing excluded the dynamin-1 related exercise-induced collapse mutation and the V547A malignant hyperthermia mutation as the cause of BCC. Common reasons for exercise intolerance were eliminated. Although a genetic basis is suspected, the cause of collapse in BCC was not determined.

  6. Effect of ultra-low doses, ASIR and MBIR on density and noise levels of MDCT images of dental implant sites.

    PubMed

    Widmann, Gerlig; Al-Shawaf, Reema; Schullian, Peter; Al-Sadhan, Ra'ed; Hörmann, Romed; Al-Ekrish, Asma'a A

    2017-05-01

    Differences in noise and density values in MDCT images obtained using ultra-low doses with FBP, ASIR, and MBIR may possibly affect implant site density analysis. The aim of this study was to compare density and noise measurements recorded from dental implant sites using ultra-low doses combined with FBP, ASIR, and MBIR. Cadavers were scanned using a standard protocol and four low-dose protocols. Scans were reconstructed using FBP, ASIR-50, ASIR-100, and MBIR, and either a bone or standard reconstruction kernel. Density (mean Hounsfield units [HUs]) of alveolar bone and noise levels (mean standard deviation of HUs) was recorded from all datasets and measurements were compared by paired t tests and two-way ANOVA with repeated measures. Significant differences in density and noise were found between the reference dose/FBP protocol and almost all test combinations. Maximum mean differences in HU were 178.35 (bone kernel) and 273.74 (standard kernel), and in noise, were 243.73 (bone kernel) and 153.88 (standard kernel). Decreasing radiation dose increased density and noise regardless of reconstruction technique and kernel. The effect of reconstruction technique on density and noise depends on the reconstruction kernel used. • Ultra-low-dose MDCT protocols allowed more than 90 % reductions in dose. • Decreasing the dose generally increased density and noise. • Effect of IRT on density and noise varies with reconstruction kernel. • Accuracy of low-dose protocols for interpretation of bony anatomy not known. • Effect of low doses on accuracy of computer-aided design models unknown.

  7. Identification of genus Acinetobacter: Standardization of in-house PCR and its comparison with conventional phenotypic methods.

    PubMed

    Kulkarni, Sughosh S; Madalgi, Radhika; Ajantha, Ganavalli S; Kulkarni, Raghavendra D

    2017-01-01

    Acinetobacter is grouped under nonfermenting Gram-negative bacilli. It is increasingly isolated from pathological samples. The ability of this genus to acquire drug resistance and spread in the hospital settings is posing a grave problem in healthcare. Specific treatment protocols are advocated for Acinetobacter infections. Hence, rapid identification and drug susceptibility profiling are critical in the management of these infections. To standardize an in-house polymerase chain reaction (PCR) for identification of genus Acinetobacter and to compare PCR with two protocols for its phenotypic identification. A total of 96 clinical isolates of Acinetobacter were included in the study. An in-house PCR for genus level identification of Acinetobacter was standardized. All the isolates were phenotypically identified by two protocols. The results of PCR and phenotypic identification protocols were compared. The in-house PCR standardized was highly sensitive and specific for the genus Acinetobacter . There was 100% agreement between the phenotypic and molecular identification of the genus. The preliminary identification tests routinely used in clinical laboratories were also in complete agreement with phenotypic and molecular identification. The in-house PCR for genus level identification is specific and sensitive. However, it may not be essential for routine identification as the preliminary phenotypic identification tests used in the clinical laboratory reliably identify the genus Acinetobacter .

  8. Spray Drift Reduction Evaluations of Spray Nozzles Using a Standardized Testing Protocol

    DTIC Science & Technology

    2010-07-01

    Drop Size Characteristics in a Spray Using Optical Nonimaging Light-Scattering Instruments,” Annual Book of ASTM Standards, Vol. 14-02, ASTM...Test Method for Determining Liquid Drop Size Characteristics in a Spray Using Optical Non- imaging Light-Scattering Instruments 22. AGDISP Model

  9. 76 FR 9025 - Agency Information Collection Activities; Proposed Collection; Comment Request; Good Laboratory...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-16

    ... consumer protection, the Agency issued GLP regulations. The regulations specify minimum standards for the proper conduct of safety testing and contain sections on facilities, personnel, equipment, standard operating procedures (SOPs), test and control articles, quality assurance, protocol and conduct of a safety...

  10. Simplified dispatch-assisted CPR instructions outperform standard protocol.

    PubMed

    Dias, J A; Brown, T B; Saini, D; Shah, R C; Cofield, S S; Waterbor, J W; Funkhouser, E; Terndrup, T E

    2007-01-01

    Dispatch-assisted chest compressions only CPR (CC-CPR) has gained widespread acceptance, and recent research suggests that increasing the proportion of compression time during CPR may increase survival from out-of-hospital cardiac arrest. We created a simplified CC-CPR protocol to reduce time to start chest compressions and to increase the proportion of time spent delivering chest compressions. This simplified protocol was compared to a published protocol, Medical Priority Dispatch System (MPDS) Version 11.2, recommended by the National Academies of Emergency Dispatch. Subjects were randomized to the MPDS v11.2 protocol or a simplified protocol. Data was recorded from a Laerdal Resusci Anne Skillreporter manikin. A simulated emergency medical dispatcher, contacted by cell phone, delivered standardized instructions for both protocols. Outcomes included chest compression rate, depth, hand position, full release, overall proportion of compressions without error, time to start of CPR and total hands-off chest time. Proportions were analyzed by Wilcoxon's Rank Sum tests and time variables with Welch ANOVA and Wilcoxon's Rank Sum test. All tests used a two-sided alpha-level of 0.05. One hundred and seventeen subjects were randomized prospectively, 58 to the standard protocol and 59 to the simplified protocol. The average age of subjects in both groups was 25 years old. For both groups, the compression rate was equivalent (104 simplified versus 94 MPDS, p = 0.13), as was the proportion with total release (1.0 simplified versus 1.0 MPDS, p = 0.09). The proportion to the correct depth was greater in the simplified protocol (0.31 versus 0.03, p < 0.01), as was the proportion of compressions done without error (0.05 versus 0.0, p = 0.16). Time to start of chest compressions and total hands-off chest time were better in the simplified protocol (start time 60.9s versus 78.6s, p < 0.0001; hands-off chest time 69 s versus 95 s, p < 0.0001). The proportion with correct hand position, however, was worse in the simplified protocol (0.35 versus 0.84, p < 0.01). The simplified protocol was as good as, or better than the MPDS v11.2 protocol in every aspect studied except hand position, and the simplified protocol resulted in significant time savings. The protocol may need modification to ensure correct hand position. Time savings and improved quality of CPR achieved by the new set of instructions could be important in strengthening critical links in the cardiac chain of survival.

  11. 75 FR 4323 - Additional Quantitative Fit-testing Protocols for the Respiratory Protection Standard

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-27

    ... respirators (500 and 1000 for protocols 1 and 2, respectively). However, OSHA could not evaluate the results... the values of these descriptive statistics for revised PortaCount[supreg] QNFT protocols 1 (at RFFs of 100 and 500) and 2 (at RFFs of 200 and 1000). Table 2--Descriptive Statistics for RFFs of 100 and 200...

  12. Evaluation of a Proposed Drift Reduction Technology High-Speed Wind Tunnel Testing Protocol

    DTIC Science & Technology

    2009-03-01

    05: “Standard Test Method for Determining Liquid Drop Size Characteristics in a Spray Using Optical Nonimaging Light- Scattering Instruments” 15...Method for Determining Liquid Drop Size Characteris- tics in a Spray Using Optical Nonimaging Light-Scattering Instruments,” Annual Book of ASTM Standards

  13. Evaluation of modifications of the traditional patch test in assessing the chemical irritation potential of feminine hygiene products.

    PubMed

    Farage, Miranda A; Meyer, Sandy; Walter, Dave

    2004-05-01

    The first main objective of the work presented in this paper was to investigate ways of optimizing the current arm patch test protocol by (1) increasing the sensitivity of the test in order to evaluate more effectively the products that are inherently non-irritating, and/or (2) reducing the costs of these types of studies by shortening the protocol. The second main objective was to use the results of these studies and the results of the parallel studies conducted using the behind-the-knee method to better understand the contribution of mechanical irritation to the skin effects produced by these types of products. In addition, we were interested in continuing the evaluation of sensory effects and their relationship to objective measures of irritation. Test materials were prepared from three, currently marketed feminine protection pads. Wet and dry samples were applied to the upper arm using the standard 24-h patch test. Applications were repeated daily for 4 consecutive days. The test sites were scored for irritation prior to the first patch application, and 30-60 min after removal of each patch. Some test sites were treated by tape stripping the skin prior to the initial patch application. In addition, in one experiment, panelists were asked to keep a daily diary describing any sensory skin effects they noticed at each test site. All protocol variations ([intact skin/dry samples], [compromised skin/dry samples], [intact skin/wet samples], and [compromised skin/wet samples]) gave similar results for the products tested. When compared to the behind-the-knee test method, the standard upper arm patch test gave consistently lower levels of irritation when the test sites were scored shortly after patch removal, even though the sample application was longer (24 vs. 6 h) in the standard patch test. The higher level of irritation in the behind-the-knee method was likely due to mechanical irritation. The sensory skin effects did not appear to be related to a particular test product or a particular protocol variation. However, the mean irritation scores at those sites where a sensory effect was reported were higher than the mean irritation scores at those sites were no sensory effects were reported. All four protocol variations of the standard upper arm patch test can be used to assess the inherent chemical irritant properties of feminine protection products. For these products, which are inherently non-irritating, tape stripping and/or applying wet samples does not increase the sensitivity of the patch test method. Differences in irritation potential were apparent after one to three 24-h applications. Therefore, the standard patch test protocol can be shortened to three applications without compromising our ability to detect differences in the chemical irritation produced by the test materials. The patch test can be used to evaluate effectively the inherent chemical irritation potential of these types of products. However, this method is not suitable for testing the mechanical irritation due to friction that occurs during product use. There is no relationship between specific test conditions, i.e., compromised skin and/or testing wet samples and reports of perceived sensory reactions. However, there seems to be a clear relationship between sensory reactions and objective irritation scores.

  14. Assessment of human epidermal model LabCyte EPI-MODEL for in vitro skin irritation testing according to European Centre for the Validation of Alternative Methods (ECVAM)-validated protocol.

    PubMed

    Katoh, Masakazu; Hamajima, Fumiyasu; Ogasawara, Takahiro; Hata, Ken-Ichiro

    2009-06-01

    A validation study of an in vitro skin irritation testing method using a reconstructed human skin model has been conducted by the European Centre for the Validation of Alternative Methods (ECVAM), and a protocol using EpiSkin (SkinEthic, France) has been approved. The structural and performance criteria of skin models for testing are defined in the ECVAM Performance Standards announced along with the approval. We have performed several evaluations of the new reconstructed human epidermal model LabCyte EPI-MODEL, and confirmed that it is applicable to skin irritation testing as defined in the ECVAM Performance Standards. We selected 19 materials (nine irritants and ten non-irritants) available in Japan as test chemicals among the 20 reference chemicals described in the ECVAM Performance Standard. A test chemical was applied to the surface of the LabCyte EPI-MODEL for 15 min, after which it was completely removed and the model then post-incubated for 42 hr. Cell v iability was measured by MTT assay and skin irritancy of the test chemical evaluated. In addition, interleukin-1 alpha (IL-1alpha) concentration in the culture supernatant after post-incubation was measured to provide a complementary evaluation of skin irritation. Evaluation of the 19 test chemicals resulted in 79% accuracy, 78% sensitivity and 80% specificity, confirming that the in vitro skin irritancy of the LabCyte EPI-MODEL correlates highly with in vivo skin irritation. These results suggest that LabCyte EPI-MODEL is applicable to the skin irritation testing protocol set out in the ECVAM Performance Standards.

  15. A randomized trial of protocol-based care for early septic shock.

    PubMed

    Yealy, Donald M; Kellum, John A; Huang, David T; Barnato, Amber E; Weissfeld, Lisa A; Pike, Francis; Terndrup, Thomas; Wang, Henry E; Hou, Peter C; LoVecchio, Frank; Filbin, Michael R; Shapiro, Nathan I; Angus, Derek C

    2014-05-01

    In a single-center study published more than a decade ago involving patients presenting to the emergency department with severe sepsis and septic shock, mortality was markedly lower among those who were treated according to a 6-hour protocol of early goal-directed therapy (EGDT), in which intravenous fluids, vasopressors, inotropes, and blood transfusions were adjusted to reach central hemodynamic targets, than among those receiving usual care. We conducted a trial to determine whether these findings were generalizable and whether all aspects of the protocol were necessary. In 31 emergency departments in the United States, we randomly assigned patients with septic shock to one of three groups for 6 hours of resuscitation: protocol-based EGDT; protocol-based standard therapy that did not require the placement of a central venous catheter, administration of inotropes, or blood transfusions; or usual care. The primary end point was 60-day in-hospital mortality. We tested sequentially whether protocol-based care (EGDT and standard-therapy groups combined) was superior to usual care and whether protocol-based EGDT was superior to protocol-based standard therapy. Secondary outcomes included longer-term mortality and the need for organ support. We enrolled 1341 patients, of whom 439 were randomly assigned to protocol-based EGDT, 446 to protocol-based standard therapy, and 456 to usual care. Resuscitation strategies differed significantly with respect to the monitoring of central venous pressure and oxygen and the use of intravenous fluids, vasopressors, inotropes, and blood transfusions. By 60 days, there were 92 deaths in the protocol-based EGDT group (21.0%), 81 in the protocol-based standard-therapy group (18.2%), and 86 in the usual-care group (18.9%) (relative risk with protocol-based therapy vs. usual care, 1.04; 95% confidence interval [CI], 0.82 to 1.31; P=0.83; relative risk with protocol-based EGDT vs. protocol-based standard therapy, 1.15; 95% CI, 0.88 to 1.51; P=0.31). There were no significant differences in 90-day mortality, 1-year mortality, or the need for organ support. In a multicenter trial conducted in the tertiary care setting, protocol-based resuscitation of patients in whom septic shock was diagnosed in the emergency department did not improve outcomes. (Funded by the National Institute of General Medical Sciences; ProCESS ClinicalTrials.gov number, NCT00510835.).

  16. Acanthamoeba: An Overview of the Challenges to the Development of a Consensus Methodology of Disinfection Efficacy Testing for Contact Lens Care Products.

    PubMed

    Brocious, Jeffrey; Tarver, Michelle E; Hampton, Denise; Eydelman, Malvina

    2018-04-24

    With the increasing incidence of more pathogens that can cause microbial keratitis (MK), it is necessary to periodically reassess disinfection multipurpose solutions testing requirements to ensure that relevant organisms to challenge them are being used. Current testing protocols have included common pathogens such as Pseudomonas aeruginosa, Staphylococcus aureus, Serratia marcescens, Candida albicans, and Fusarium solani but have omitted less common pathogens such as Acanthamoeba. Specifically, Acanthamoeba sp. has recently been identified as a prevalent cause of MK in certain countries. Developing an appropriate protocol for this unique organism presents a challenge, given its two distinct life stages, methods to grow the organism, encystment techniques, and many other parameters that can affect testing outcomes. Therefore, the appropriate combination of these parameters is crucial to developing a protocol that ensures consistent, accurate results. The FDA has recognized the importance of establishing a standardized testing protocol for this pathogen and embarked on research efforts to provide a recommended testing protocol for testing contact lens care products.

  17. Prospective Evaluation of a Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry System in a Hospital Clinical Microbiology Laboratory for Identification of Bacteria and Yeasts: a Bench-by-Bench Study for Assessing the Impact on Time to Identification and Cost-Effectiveness

    PubMed Central

    Tan, K. E.; Ellis, B. C.; Lee, R.; Stamper, P. D.; Zhang, S. X.

    2012-01-01

    Matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) has been found to be an accurate, rapid, and inexpensive method for the identification of bacteria and yeasts. Previous evaluations have compared the accuracy, time to identification, and costs of the MALDI-TOF MS method against standard identification systems or commercial panels. In this prospective study, we compared a protocol incorporating MALDI-TOF MS (MALDI protocol) with the current standard identification protocols (standard protocol) to determine the performance in actual practice using a specimen-based, bench-by-bench approach. The potential impact on time to identification (TTI) and costs had MALDI-TOF MS been the first-line identification method was quantitated. The MALDI protocol includes supplementary tests, notably for Streptococcus pneumoniae and Shigella, and indications for repeat MALDI-TOF MS attempts, often not measured in previous studies. A total of 952 isolates (824 bacterial isolates and 128 yeast isolates) recovered from 2,214 specimens were assessed using the MALDI protocol. Compared with standard protocols, the MALDI protocol provided identifications 1.45 days earlier on average (P < 0.001). In our laboratory, we anticipate that the incorporation of the MALDI protocol can reduce reagent and labor costs of identification by $102,424 or 56.9% within 12 months. The model included the fixed annual costs of the MALDI-TOF MS, such as the cost of protein standards and instrument maintenance, and the annual prevalence of organisms encountered in our laboratory. This comprehensive cost analysis model can be generalized to other moderate- to high-volume laboratories. PMID:22855510

  18. Prospective evaluation of a matrix-assisted laser desorption ionization-time of flight mass spectrometry system in a hospital clinical microbiology laboratory for identification of bacteria and yeasts: a bench-by-bench study for assessing the impact on time to identification and cost-effectiveness.

    PubMed

    Tan, K E; Ellis, B C; Lee, R; Stamper, P D; Zhang, S X; Carroll, K C

    2012-10-01

    Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has been found to be an accurate, rapid, and inexpensive method for the identification of bacteria and yeasts. Previous evaluations have compared the accuracy, time to identification, and costs of the MALDI-TOF MS method against standard identification systems or commercial panels. In this prospective study, we compared a protocol incorporating MALDI-TOF MS (MALDI protocol) with the current standard identification protocols (standard protocol) to determine the performance in actual practice using a specimen-based, bench-by-bench approach. The potential impact on time to identification (TTI) and costs had MALDI-TOF MS been the first-line identification method was quantitated. The MALDI protocol includes supplementary tests, notably for Streptococcus pneumoniae and Shigella, and indications for repeat MALDI-TOF MS attempts, often not measured in previous studies. A total of 952 isolates (824 bacterial isolates and 128 yeast isolates) recovered from 2,214 specimens were assessed using the MALDI protocol. Compared with standard protocols, the MALDI protocol provided identifications 1.45 days earlier on average (P < 0.001). In our laboratory, we anticipate that the incorporation of the MALDI protocol can reduce reagent and labor costs of identification by $102,424 or 56.9% within 12 months. The model included the fixed annual costs of the MALDI-TOF MS, such as the cost of protein standards and instrument maintenance, and the annual prevalence of organisms encountered in our laboratory. This comprehensive cost analysis model can be generalized to other moderate- to high-volume laboratories.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wohlgemuth, John; Silverman, Timothy; Miller, David C.

    This paper describes an effort to inspect and evaluate PV modules in order to determine what failure or degradation modes are occurring in field installations. This paper will report on the results of six site visits, including the Sacramento Municipal Utility District (SMUD) Hedge Array, Tucson Electric Power (TEP) Springerville, Central Florida Utility, Florida Solar Energy Center (FSEC), the TEP Solar Test Yard, and University of Toledo installations. The effort here makes use of a recently developed field inspection data collection protocol, and the results were input into a corresponding database. The results of this work have also been usedmore » to develop a draft of the IEC standard for climate and application specific accelerated stress testing beyond module qualification. TEP Solar Test Yard, and University of Toledo installations. The effort here makes use of a recently developed field inspection data collection protocol, and the results were input into a corresponding database. The results of this work have also been used to develop a draft of the IEC standard for climate and application specific accelerated stress testing beyond module qualification. TEP Solar Test Yard, and University of Toledo installations. The effort here makes use of a recently developed field inspection data collection protocol, and the results were input into a corresponding database. The results of this work have also been used to develop a draft of the IEC standard for climate and application specific accelerated stress testing beyond module qualification.« less

  20. GENERIC VERIFICATION PROTOCOL FOR DETERMINATION OF EMISSIONS REDUCTIONS OBTAINED BY USE OF ALTERNATIVE OR REFORMULATED LIQUID FUELS, FUEL ADDITIVES, FUEL EMULSIONS AND LUBRICANTS FOR HIGHWAY AND NONROAD USE DISEL ENGINES AND LIGHT DUTY GASOLINE ENGINES AND VEHICLES

    EPA Science Inventory

    This report sets standards by which the emissions reduction provided by fuel and lubricant technologies can be tested and be tested in a comparable way. It is a generic protocol under the Environmental Technology Verification program.

  1. Use of a standardized JaCVAM in vivo rat comet assay protocol to assess the genotoxicity of three coded test compounds; ampicillin trihydrate, 1,2-dimethylhydrazine dihydrochloride, and N-nitrosodimethylamine.

    PubMed

    McNamee, J P; Bellier, P V

    2015-07-01

    As part of the Japanese Center for the Validation of Alternative Methods (JaCVAM)-initiative international validation study of the in vivo rat alkaline comet assay (comet assay), our laboratory examined ampicillin trihydrate (AMP), 1,2-dimethylhydrazine dihydrochloride (DMH), and N-nitrosodimethylamine (NDA) using a standard comet assay validation protocol (v14.2) developed by the JaCVAM validation management team (VMT). Coded samples were received by our laboratory along with basic MSDS information. Solubility analysis and range-finding experiments of the coded test compounds were conducted for dose selection. Animal dosing schedules, the comet assay processing and analysis, and statistical analysis were conducted in accordance with the standard protocol. Based upon our blinded evaluation, AMP was not found to exhibit evidence of genotoxicity in either the rat liver or stomach. However, both NDA and DMH were observed to cause a significant increase in % tail DNA in the rat liver at all dose levels tested. While acute hepatoxicity was observed for these compounds in the high dose group, in the investigators opinion there were a sufficient number of consistently damaged/measurable cells at the medium and low dose groups to judge these compounds as genotoxic. There was no evidence of genotoxicity from either NDA or DMH in the rat stomach. In conclusion, our laboratory observed increased DNA damage from two blinded test compounds in rat liver (later identified as genotoxic carcinogens), while no evidence of genotoxicity was observed for the third blinded test compound (later identified as a non-genotoxic, non-carcinogen). This data supports the use of a standardized protocol of the in vivo comet assay as a cost-effective alternative genotoxicity assay for regulatory testing purposes. Crown Copyright © 2015. Published by Elsevier B.V. All rights reserved.

  2. Electric Vehicle and Wireless Charging Laboratory

    DOT National Transportation Integrated Search

    2018-03-23

    Wireless charging tests of electric vehicles (EV) have been conducted at the EVTC Wireless Laboratory located at the Florida Solar Energy Center, Cocoa, FL. These tests were performed to document testing protocols, evaluate standards and evaluate ope...

  3. Techniques and Protocols for Dispersing Nanoparticle Powders in Aqueous Media-Is there a Rationale for Harmonization?

    PubMed

    Hartmann, Nanna B; Jensen, Keld Alstrup; Baun, Anders; Rasmussen, Kirsten; Rauscher, Hubert; Tantra, Ratna; Cupi, Denisa; Gilliland, Douglas; Pianella, Francesca; Riego Sintes, Juan M

    2015-01-01

    Selecting appropriate ways of bringing engineered nanoparticles (ENP) into aqueous dispersion is a main obstacle for testing, and thus for understanding and evaluating, their potential adverse effects to the environment and human health. Using different methods to prepare (stock) dispersions of the same ENP may be a source of variation in the toxicity measured. Harmonization and standardization of dispersion methods applied in mammalian and ecotoxicity testing are needed to ensure a comparable data quality and to minimize test artifacts produced by modifications of ENP during the dispersion preparation process. Such harmonization and standardization will also enhance comparability among tests, labs, and studies on different types of ENP. The scope of this review was to critically discuss the essential parameters in dispersion protocols for ENP. The parameters are identified from individual scientific studies and from consensus reached in larger scale research projects and international organizations. A step-wise approach is proposed to develop tailored dispersion protocols for ecotoxicological and mammalian toxicological testing of ENP. The recommendations of this analysis may serve as a guide to researchers, companies, and regulators when selecting, developing, and evaluating the appropriateness of dispersion methods applied in mammalian and ecotoxicity testing. However, additional experimentation is needed to further document the protocol parameters and investigate to what extent different stock dispersion methods affect ecotoxicological and mammalian toxicological responses of ENP.

  4. Performance evaluation of complete data transfer of physical layer according to IEEE 802.15.4 standard

    NASA Astrophysics Data System (ADS)

    Raju, Kota Solomon; Merugu, Naresh Babu; Neetu, Babu, E. Ram

    2016-03-01

    ZigBee is well-accepted industrial standard for wireless sensor networks based on IEEE 802.15.4 standard. Wireless Sensor Networks is the major concern of communication these days. These Wireless Sensor Networks investigate the properties of networks of small battery-powered sensors with wireless communication. The communication between any two wireless nodes of wireless sensor networks is carried out through a protocol stack. This protocol stack has been designed by different vendors in various ways. Every custom vendor possesses his own protocol stack and algorithms especially at the MAC layer. But, many applications require modifications in their algorithms at various layers as per their requirements, especially energy efficient protocols at MAC layer that are simulated in Wireless sensor Network Simulators which are not being tested in real time systems because vendors do not allow the programmability of each layer in their protocol stack. This problem can be quoted as Vendor-Interoperability. The solution is to develop the programmable protocol stack where we can design our own application as required. As a part of the task first we tried implementing physical layer and transmission of data using physical layer. This paper describes about the transmission of the total number of bytes of Frame according to the IEEE 802.15.4 standard using Physical Layer.

  5. Measurement properties of maximal cardiopulmonary exercise tests protocols in persons after stroke: A systematic review.

    PubMed

    Wittink, Harriet; Verschuren, Olaf; Terwee, Caroline; de Groot, Janke; Kwakkel, Gert; van de Port, Ingrid

    2017-11-21

    To systematically review and critically appraise the literature on measurement properties of cardiopulmonary exercise test protocols for measuring aerobic capacity, VO2max, in persons after stroke. PubMed, Embase and Cinahl were searched from inception up to 15 June 2016. A total of 9 studies were identified reporting on 9 different cardiopulmonary exercise test protocols. VO2max measured with cardiopulmonary exercise test and open spirometry was the construct of interest. The target population was adult persons after stroke. We included all studies that evaluated reliability, measurement error, criterion validity, content validity, hypothesis testing and/or responsiveness of cardiopulmonary exercise test protocols. Two researchers independently screened the literature, assessed methodological quality using the COnsensus-based Standards for the selection of health Measurement INstruments checklist and extracted data on measurement properties of cardiopulmonary exercise test protocols. Most studies reported on only one measurement property. Best-evidence synthesis was derived taking into account the methodological quality of the studies, the results and the consistency of the results. No judgement could be made on which protocol is "best" for measuring VO2max in persons after stroke due to lack of high-quality studies on the measurement properties of the cardiopulmonary exercise test.

  6. 21 CFR 660.46 - Samples; protocols; official release.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Samples; protocols; official release. 660.46 Section 660.46 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Hepatitis B Surface...

  7. Toward Reliable Lipoprotein Particle Predictions from NMR Spectra of Human Blood: An Interlaboratory Ring Test.

    PubMed

    Monsonis Centelles, Sandra; Hoefsloot, Huub C J; Khakimov, Bekzod; Ebrahimi, Parvaneh; Lind, Mads V; Kristensen, Mette; de Roo, Niels; Jacobs, Doris M; van Duynhoven, John; Cannet, Claire; Fang, Fang; Humpfer, Eberhard; Schäfer, Hartmut; Spraul, Manfred; Engelsen, Søren B; Smilde, Age K

    2017-08-01

    Lipoprotein profiling of human blood by 1 H nuclear magnetic resonance (NMR) spectroscopy is a rapid and promising approach to monitor health and disease states in medicine and nutrition. However, lack of standardization of measurement protocols has prevented the use of NMR-based lipoprotein profiling in metastudies. In this study, a standardized NMR measurement protocol was applied in a ring test performed across three different laboratories in Europe on plasma and serum samples from 28 individuals. Data was evaluated in terms of (i) spectral differences, (ii) differences in LPD predictions obtained using an existing prediction model, and (iii) agreement of predictions with cholesterol concentrations in high- and low-density lipoproteins (HDL and LDL) particles measured by standardized clinical assays. ANOVA-simultaneous component analysis (ASCA) of the ring test spectral ensemble that contains methylene and methyl peaks (1.4-0.6 ppm) showed that 97.99% of the variance in the data is related to subject, 1.62% to sample type (serum or plasma), and 0.39% to laboratory. This interlaboratory variation is in fact smaller than the maximum acceptable intralaboratory variation on quality control samples. It is also shown that the reproducibility between laboratories is good enough for the LPD predictions to be exchangeable when the standardized NMR measurement protocol is followed. With the successful implementation of this protocol, which results in reproducible prediction of lipoprotein distributions across laboratories, a step is taken toward bringing NMR more into scope of prognostic and diagnostic biomarkers, reducing the need for less efficient methods such as ultracentrifugation or high-performance liquid chromatography (HPLC).

  8. A tonic heat test stimulus yields a larger and more reliable conditioned pain modulation effect compared to a phasic heat test stimulus

    PubMed Central

    Lie, Marie Udnesseter; Matre, Dagfinn; Hansson, Per; Stubhaug, Audun; Zwart, John-Anker; Nilsen, Kristian Bernhard

    2017-01-01

    Abstract Introduction: The interest in conditioned pain modulation (CPM) as a clinical tool for measuring endogenously induced analgesia is increasing. There is, however, large variation in the CPM methodology, hindering comparison of results across studies. Research comparing different CPM protocols is needed in order to obtain a standardized test paradigm. Objectives: The aim of the study was to assess whether a protocol with phasic heat stimuli as test-stimulus is preferable to a protocol with tonic heat stimulus as test-stimulus. Methods: In this experimental crossover study, we compared 2 CPM protocols with different test-stimulus; one with tonic test-stimulus (constant heat stimulus of 120-second duration) and one with phasic test-stimuli (3 heat stimulations of 5 seconds duration separated by 10 seconds). Conditioning stimulus was a 7°C water bath in parallel with the test-stimulus. Twenty-four healthy volunteers were assessed on 2 occasions with minimum 1 week apart. Differences in the magnitude and test–retest reliability of the CPM effect in the 2 protocols were investigated with repeated-measures analysis of variance and by relative and absolute reliability indices. Results: The protocol with tonic test-stimulus induced a significantly larger CPM effect compared to the protocol with phasic test-stimuli (P < 0.001). Fair and good relative reliability was found with the phasic and tonic test-stimuli, respectively. Absolute reliability indices showed large intraindividual variability from session to session in both protocols. Conclusion: The present study shows that a CPM protocol with a tonic test-stimulus is preferable to a protocol with phasic test-stimuli. However, we emphasize that one should be cautious to use the CPM effect as biomarker or in clinical decision making on an individual level due to large intraindividual variability. PMID:29392240

  9. Physical and perceptual estimation of differences between loudspeakers

    NASA Astrophysics Data System (ADS)

    Lavandier, Mathieu; Herzog, Philippe; Meunier, Sabine

    2006-12-01

    Differentiating the restitution of timbre by several loudspeakers may result from standard measurements, or from listening tests. This work proposes a protocol keeping a close relationship between the objective and perceptual evaluations: the stimuli are musical excerpts, and the measuring environment is a standard listening room. The protocol involves recordings made at a listener position, and objective dissimilarities are computed using an auditory model simulating masking effects. The resulting data correlate very well with listening tests using the same recordings, and show similar dependencies on the major parameters identified from the dissimilarity matrices. To cite this article: M. Lavandier et al., C. R. Mecanique 334 (2006).

  10. D-RATS 2011: RAFT Protocol Overview

    NASA Technical Reports Server (NTRS)

    Utz, Hans

    2011-01-01

    A brief overview presentation on the protocol used during the D-RATS2011 field test for file transfer from the field-test robots at Black Point Lava Flow AZ to Johnson Space Center, Houston TX over a simulated time-delay. The file transfer actually uses a commercial implementation of an open communications standard. The focus of the work lies on how to make the state of the distributed system observable.

  11. Application of QC_DR software for acceptance testing and routine quality control of direct digital radiography systems: initial experiences using the Italian Association of Physicist in Medicine quality control protocol.

    PubMed

    Nitrosi, Andrea; Bertolini, Marco; Borasi, Giovanni; Botti, Andrea; Barani, Adriana; Rivetti, Stefano; Pierotti, Luisa

    2009-12-01

    Ideally, medical x-ray imaging systems should be designed to deliver maximum image quality at an acceptable radiation risk to the patient. Quality assurance procedures are employed to ensure that these standards are maintained. A quality control protocol for direct digital radiography (DDR) systems is described and discussed. Software to automatically process and analyze the required images was developed. In this paper, the initial results obtained on equipment of different DDR manufacturers were reported. The protocol was developed to highlight even small discrepancies in standard operating performance.

  12. Effect of test exercises and mask donning on measured respirator fit.

    PubMed

    Crutchfield, C D; Fairbank, E O; Greenstein, S L

    1999-12-01

    Quantitative respirator fit test protocols are typically defined by a series of fit test exercises. A rationale for the protocols that have been developed is generally not available. There also is little information available that describes the effect or effectiveness of the fit test exercises currently specified in respiratory protection standards. This study was designed to assess the relative impact of fit test exercises and mask donning on respirator fit as measured by a controlled negative pressure and an ambient aerosol fit test system. Multiple donnings of two different sizes of identical respirator models by each of 14 test subjects showed that donning affects respirator fit to a greater degree than fit test exercises. Currently specified fit test protocols emphasize test exercises, and the determination of fit is based on a single mask donning. A rationale for a modified fit test protocol based on fewer, more targeted test exercises and multiple mask donnings is presented. The modified protocol identified inadequately fitting respirators as effectively as the currently specified Occupational Safety and Health Administration (OSHA) quantitative fit test protocol. The controlled negative pressure system measured significantly (p < 0.0001) more respirator leakage than the ambient aerosol fit test system. The bend over fit test exercise was found to be predictive of poor respirator fit by both fit test systems. For the better fitting respirators, only the talking exercise generated aerosol fit factors that were significantly lower (p < 0.0001) than corresponding donning fit factors.

  13. Protocol for Usability Testing and Validation of the ISO Draft International Standard 19223 for Lung Ventilators

    PubMed Central

    2017-01-01

    Background Clinicians, such as respiratory therapists and physicians, are often required to set up pieces of medical equipment that use inconsistent terminology. Current lung ventilator terminology that is used by different manufacturers contributes to the risk of usage errors, and in turn the risk of ventilator-associated lung injuries and other conditions. Human factors and communication issues are often associated with ventilator-related sentinel events, and inconsistent ventilator terminology compounds these issues. This paper describes our proposed protocol, which will be implemented at the University of Waterloo, Canada when this project is externally funded. Objective We propose to determine whether a standardized vocabulary improves the ease of use, safety, and utility as it relates to the usability of medical devices, compared to legacy medical devices from multiple manufacturers, which use different terms. Methods We hypothesize that usage errors by clinicians will be lower when standardization is consistently applied by all manufacturers. The proposed study will experimentally examine the impact of standardized nomenclature on performance declines in the use of an unfamiliar ventilator product in clinically relevant scenarios. Participants will be respiratory therapy practitioners and trainees, and we propose studying approximately 60 participants. Results The work reported here is in the proposal phase. Once the protocol is implemented, we will report the results in a follow-up paper. Conclusions The proposed study will help us better understand the effects of standardization on medical device usability. The study will also help identify any terms in the International Organization for Standardization (ISO) Draft International Standard (DIS) 19223 that may be associated with recurrent errors. Amendments to the standard will be proposed if recurrent errors are identified. This report contributes a protocol that can be used to assess the effect of standardization in any given domain that involves equipment, multiple manufacturers, inconsistent vocabulary, symbology, audio tones, or patterns in interface navigation. Second, the protocol can be used to experimentally evaluate the ISO DIS 19223 for its effectiveness, as researchers around the world may wish to conduct such tests and compare results. PMID:28887292

  14. Optimizing the high-resolution manometry (HRM) study protocol.

    PubMed

    Patel, A; Ding, A; Mirza, F; Gyawali, C P

    2015-02-01

    Intolerance of the esophageal manometry catheter may prolong high-resolution manometry (HRM) studies and increase patient distress. We assessed the impact of obtaining the landmark phase at the end of the study when the patient has acclimatized to the HRM catheter. 366 patients (mean age 55.4 ± 0.8 years, 62.0% female) undergoing esophageal HRM over a 1-year period were studied. The standard protocol consisted of the landmark phase, 10 5 mL water swallows 20-30 s apart, and multiple rapid swallows where 4-6 2 mL swallows were administered in rapid succession. The modified protocol consisted of the landmark phase at the end of the study after test swallows. Study duration, technical characteristics, indications, and motor findings were compared between standard and modified protocols. Of the 366 patients, 89.6% underwent the standard protocol (study duration 12.9 ± 0.3 min). In 10.4% with poor catheter tolerance undergoing the modified protocol, study duration was significantly longer (15.6 ± 1.0 min, p = 0.004) despite similar duration of study maneuvers. Only elevated upper esophageal sphincter basal pressures at the beginning of the study segregated modified protocol patients. The 95th percentile time to landmark phase in the standard protocol patients was 6.1 min; as many as 31.4% of modified protocol patients could not obtain their first study maneuver within this period (p = 0.0003). Interpretation was not impacted by shifting the landmark phase to the end of the study. Modification of the HRM study protocol with the landmark phase obtained at the end of the study optimizes study duration without compromising quality. © 2014 John Wiley & Sons Ltd.

  15. Working towards accreditation by the International Standards Organization 15189 Standard: how to validate an in-house developed method an example of lead determination in whole blood by electrothermal atomic absorption spectrometry.

    PubMed

    Garcia Hejl, Carine; Ramirez, Jose Manuel; Vest, Philippe; Chianea, Denis; Renard, Christophe

    2014-09-01

    Laboratories working towards accreditation by the International Standards Organization (ISO) 15189 standard are required to demonstrate the validity of their analytical methods. The different guidelines set by various accreditation organizations make it difficult to provide objective evidence that an in-house method is fit for the intended purpose. Besides, the required performance characteristics tests and acceptance criteria are not always detailed. The laboratory must choose the most suitable validation protocol and set the acceptance criteria. Therefore, we propose a validation protocol to evaluate the performance of an in-house method. As an example, we validated the process for the detection and quantification of lead in whole blood by electrothermal absorption spectrometry. The fundamental parameters tested were, selectivity, calibration model, precision, accuracy (and uncertainty of measurement), contamination, stability of the sample, reference interval, and analytical interference. We have developed a protocol that has been applied successfully to quantify lead in whole blood by electrothermal atomic absorption spectrometry (ETAAS). In particular, our method is selective, linear, accurate, and precise, making it suitable for use in routine diagnostics.

  16. Prototype development and implementation of picture archiving and communications systems based on ISO-OSI standard

    NASA Astrophysics Data System (ADS)

    Martinez, Ralph; Nam, Jiseung

    1992-07-01

    Picture Archiving and Communication Systems (PACS) is an integration of digital image formation in a hospital, which encompasses various imaging equipment, image viewing workstations, image databases, and a high speed network. The integration requires a standardization of communication protocols to connect devices from different vendors. The American College of Radiology and the National Electrical Manufacturers Association (ACR- NEMA) standard Version 2.0 provides a point-to-point hardware interface, a set of software commands, and a consistent set of data formats for PACS. But, it is inadequate for PACS networking environments, because of its point-to-point nature and its inflexibility to allow other services and protocols in the future. Based on previous experience of PACS developments in The University of Arizona, a new communication protocol for PACS networks and an approach were proposed to ACR-NEMA Working Group VI. The defined PACS protocol is intended to facilitate the development of PACS''s capable of interfacing with other hospital information systems. Also, it is intended to allow the creation of diagnostic information data bases which can be interrogated by a variety of distributed devices. A particularly important goal is to support communications in a multivendor environment. The new protocol specifications are defined primarily as a combination of the International Organization for Standardization/Open Systems Interconnection (ISO/OSI), TCP/IP protocols, and the data format portion of ACR-NEMA standard. This paper addresses the specification and implementation of the ISO-based protocol into a PACS prototype. The protocol specification, which covers Presentation, Session, Transport, and Network layers, is summarized briefly. The protocol implementation is discussed based on our implementation efforts in the UNIX Operating System Environment. At the same time, results of performance comparison between the ISO and TCP/IP implementations are presented to demonstrate the implementation of defined protocol. The testing of performance analysis is done by prototyping PACS on available platforms, which are Micro VAX II, DECstation and SUN Workstation.

  17. A standard protocol for describing individual-based and agent-based models

    USGS Publications Warehouse

    Grimm, Volker; Berger, Uta; Bastiansen, Finn; Eliassen, Sigrunn; Ginot, Vincent; Giske, Jarl; Goss-Custard, John; Grand, Tamara; Heinz, Simone K.; Huse, Geir; Huth, Andreas; Jepsen, Jane U.; Jorgensen, Christian; Mooij, Wolf M.; Muller, Birgit; Pe'er, Guy; Piou, Cyril; Railsback, Steven F.; Robbins, Andrew M.; Robbins, Martha M.; Rossmanith, Eva; Ruger, Nadja; Strand, Espen; Souissi, Sami; Stillman, Richard A.; Vabo, Rune; Visser, Ute; DeAngelis, Donald L.

    2006-01-01

    Simulation models that describe autonomous individual organisms (individual based models, IBM) or agents (agent-based models, ABM) have become a widely used tool, not only in ecology, but also in many other disciplines dealing with complex systems made up of autonomous entities. However, there is no standard protocol for describing such simulation models, which can make them difficult to understand and to duplicate. This paper presents a proposed standard protocol, ODD, for describing IBMs and ABMs, developed and tested by 28 modellers who cover a wide range of fields within ecology. This protocol consists of three blocks (Overview, Design concepts, and Details), which are subdivided into seven elements: Purpose, State variables and scales, Process overview and scheduling, Design concepts, Initialization, Input, and Submodels. We explain which aspects of a model should be described in each element, and we present an example to illustrate the protocol in use. In addition, 19 examples are available in an Online Appendix. We consider ODD as a first step for establishing a more detailed common format of the description of IBMs and ABMs. Once initiated, the protocol will hopefully evolve as it becomes used by a sufficiently large proportion of modellers.

  18. Kilovoltage cone-beam CT: Comparative dose and image quality evaluations in partial and full-angle scan protocols

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Sangroh; Yoo, Sua; Yin Fangfang

    2010-07-15

    Purpose: To assess imaging dose of partial and full-angle kilovoltage CBCT scan protocols and to evaluate image quality for each protocol. Methods: The authors obtained the CT dose index (CTDI) of the kilovoltage CBCT protocols in an on-board imager by ion chamber (IC) measurements and Monte Carlo (MC) simulations. A total of six new CBCT scan protocols were evaluated: Standard-dose head (100 kVp, 151 mA s, partial-angle), low-dose head (100 kVp, 75 mA s, partial-angle), high-quality head (100 kVp, 754 mA s, partial-angle), pelvis (125 kVp, 706 mA s, full-angle), pelvis spotlight (125 kVp, 752 mA s, partial-angle), and low-dosemore » thorax (110 kVp, 271 mA s, full-angle). Using the point dose method, various CTDI values were calculated by (1) the conventional weighted CTDI (CTDI{sub w}) calculation and (2) Bakalyar's method (CTDI{sub wb}). The MC simulations were performed to obtain the CTDI{sub w} and CTDI{sub wb}, as well as from (3) central slice averaging (CTDI{sub 2D}) and (4) volume averaging (CTDI{sub 3D}) techniques. The CTDI values of the new protocols were compared to those of the old protocols (full-angle CBCT protocols). Image quality of the new protocols was evaluated following the CBCT image quality assurance (QA) protocol [S. Yoo et al., ''A quality assurance program for the on-board imager registered ,'' Med. Phys. 33(11), 4431-4447 (2006)] testing Hounsfield unit (HU) linearity, spatial linearity/resolution, contrast resolution, and HU uniformity. Results: The CTDI{sub w} were found as 6.0, 3.2, 29.0, 25.4, 23.8, and 7.7 mGy for the new protocols, respectively. The CTDI{sub w} and CTDI{sub wb} differed within +3% between IC measurements and MC simulations. Method (2) results were within {+-}12% of method (1). In MC simulations, the CTDI{sub w} and CTDI{sub wb} were comparable to the CTDI{sub 2D} and CTDI{sub 3D} with the differences ranging from -4.3% to 20.6%. The CTDI{sub 3D} were smallest among all the CTDI values. CTDI{sub w} of the new protocols were found as {approx}14 times lower for standard head scan and 1.8 times lower for standard body scan than the old protocols, respectively. In the image quality QA tests, all the protocols except low-dose head and low-dose thorax protocols were within the tolerance in the HU verification test. The HU value for the two protocols was always higher than the nominal value. All the protocols passed the spatial linearity/resolution and HU uniformity tests. In the contrast resolution test, only high-quality head and pelvis scan protocols were within the tolerance. In addition, crescent effect was found in the partial-angle scan protocols. Conclusions: The authors found that CTDI{sub w} of the new CBCT protocols has been significantly reduced compared to the old protocols with acceptable image quality. The CTDI{sub w} values in the point dose method were close to the volume averaging method within 9%-21% for all the CBCT scan protocols. The Bakalyar's method produced more accurate dose estimation within 14%. The HU inaccuracy from low-dose head and low-dose thorax protocols can render incorrect dose results in the treatment planning system. When high soft-tissue contrast data are desired, high-quality head or pelvis scan protocol is recommended depending on the imaging area. The point dose method can be applicable to estimate CBCT dose with reasonable accuracy in the clinical environment.« less

  19. Automated, Quantitative Cognitive/Behavioral Screening of Mice: For Genetics, Pharmacology, Animal Cognition and Undergraduate Instruction

    PubMed Central

    Gallistel, C. R.; Balci, Fuat; Freestone, David; Kheifets, Aaron; King, Adam

    2014-01-01

    We describe a high-throughput, high-volume, fully automated, live-in 24/7 behavioral testing system for assessing the effects of genetic and pharmacological manipulations on basic mechanisms of cognition and learning in mice. A standard polypropylene mouse housing tub is connected through an acrylic tube to a standard commercial mouse test box. The test box has 3 hoppers, 2 of which are connected to pellet feeders. All are internally illuminable with an LED and monitored for head entries by infrared (IR) beams. Mice live in the environment, which eliminates handling during screening. They obtain their food during two or more daily feeding periods by performing in operant (instrumental) and Pavlovian (classical) protocols, for which we have written protocol-control software and quasi-real-time data analysis and graphing software. The data analysis and graphing routines are written in a MATLAB-based language created to simplify greatly the analysis of large time-stamped behavioral and physiological event records and to preserve a full data trail from raw data through all intermediate analyses to the published graphs and statistics within a single data structure. The data-analysis code harvests the data several times a day and subjects it to statistical and graphical analyses, which are automatically stored in the "cloud" and on in-lab computers. Thus, the progress of individual mice is visualized and quantified daily. The data-analysis code talks to the protocol-control code, permitting the automated advance from protocol to protocol of individual subjects. The behavioral protocols implemented are matching, autoshaping, timed hopper-switching, risk assessment in timed hopper-switching, impulsivity measurement, and the circadian anticipation of food availability. Open-source protocol-control and data-analysis code makes the addition of new protocols simple. Eight test environments fit in a 48 in x 24 in x 78 in cabinet; two such cabinets (16 environments) may be controlled by one computer. PMID:24637442

  20. Automated, quantitative cognitive/behavioral screening of mice: for genetics, pharmacology, animal cognition and undergraduate instruction.

    PubMed

    Gallistel, C R; Balci, Fuat; Freestone, David; Kheifets, Aaron; King, Adam

    2014-02-26

    We describe a high-throughput, high-volume, fully automated, live-in 24/7 behavioral testing system for assessing the effects of genetic and pharmacological manipulations on basic mechanisms of cognition and learning in mice. A standard polypropylene mouse housing tub is connected through an acrylic tube to a standard commercial mouse test box. The test box has 3 hoppers, 2 of which are connected to pellet feeders. All are internally illuminable with an LED and monitored for head entries by infrared (IR) beams. Mice live in the environment, which eliminates handling during screening. They obtain their food during two or more daily feeding periods by performing in operant (instrumental) and Pavlovian (classical) protocols, for which we have written protocol-control software and quasi-real-time data analysis and graphing software. The data analysis and graphing routines are written in a MATLAB-based language created to simplify greatly the analysis of large time-stamped behavioral and physiological event records and to preserve a full data trail from raw data through all intermediate analyses to the published graphs and statistics within a single data structure. The data-analysis code harvests the data several times a day and subjects it to statistical and graphical analyses, which are automatically stored in the "cloud" and on in-lab computers. Thus, the progress of individual mice is visualized and quantified daily. The data-analysis code talks to the protocol-control code, permitting the automated advance from protocol to protocol of individual subjects. The behavioral protocols implemented are matching, autoshaping, timed hopper-switching, risk assessment in timed hopper-switching, impulsivity measurement, and the circadian anticipation of food availability. Open-source protocol-control and data-analysis code makes the addition of new protocols simple. Eight test environments fit in a 48 in x 24 in x 78 in cabinet; two such cabinets (16 environments) may be controlled by one computer.

  1. Turkish version of the modified Constant-Murley score and standardized test protocol: reliability and validity.

    PubMed

    Çelik, Derya

    2016-01-01

    The Constant-Murley score (CMS) is widely used to evaluate disabilities associated with shoulder injuries, but it has been criticized for relying on imprecise terminology and a lack of standardized methodology. A modified guideline, therefore, was published in 2008 with several recommendations. This new version has not yet been translated or culturally adapted for Turkish-speaking populations. The purpose of this study was to translate and cross-culturally adapt the modified CMS and its test protocol, as well as define and measure its reliability and validity. The modified CMS was translated into Turkish, consistent with published methodological guidelines. The measurement properties of the Turkish version of the modified CMS were tested in 30 patients (12 males, 18 females; mean age: 59.5±13.5 years) with a variety of shoulder pathologies. Intraclass correlation coefficients (ICC) were used to estimate test-retest reliability. Construct validity was analyzed with the Turkish version of the American Shoulder and Elbow Surgeons (ASES) Standardized Shoulder Assessment Form and Short-Form Health Survey (SF-12). No difficulties were found in the translation process. The Turkish version of the modified CMS showed excellent test-retest reliability (ICC=0.86). The correlation coefficients between the Turkish version of the modified CMS and the ASES, SF-12-physical component score, and SF-12 mental component scores were found to be 0.48, 0.35, and 0.05, respectively. No floor or ceiling effects were found. The translation and cultural adaptation of the modified CMS and its standardized test protocol into Turkish were successful. The Turkish version of the modified CMS has sufficient reliability and validity to measure a variety of shoulder disorders for Turkish-speaking individuals.

  2. Documentation of operational protocol for the use of MAMA software

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schwartz, Daniel S.

    2016-01-21

    Image analysis of Scanning Electron Microscope (SEM) micrographs is a complex process that can vary significantly between analysts. The factors causing the variation are numerous, and the purpose of Task 2b is to develop and test a set of protocols designed to minimize variation in image analysis between different analysts and laboratories, specifically using the MAMA software package, Version 2.1. The protocols were designed to be “minimally invasive”, so that expert SEM operators will not be overly constrained in the way they analyze particle samples. The protocols will be tested using a round-robin approach where results from expert SEM usersmore » at Los Alamos National Laboratory, Lawrence Livermore National Laboratory, Pacific Northwest National Laboratory, Savannah River National Laboratory, and the National Institute of Standards and Testing will be compared. The variation of the results will be used to quantify uncertainty in the particle image analysis process. The round-robin exercise will proceed with 3 levels of rigor, each with their own set of protocols, as described below in Tasks 2b.1, 2b.2, and 2b.3. The uncertainty will be developed using NIST standard reference material SRM 1984 “Thermal Spray Powder – Particle Size Distribution, Tungsten Carbide/Cobalt (Acicular)” [Reference 1]. Full details are available in the Certificate of Analysis, posted on the NIST website (http://www.nist.gov/srm/).« less

  3. 40 CFR 792.130 - Conduct of a study.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 32 2011-07-01 2011-07-01 false Conduct of a study. 792.130 Section... ACT (CONTINUED) GOOD LABORATORY PRACTICE STANDARDS Protocol for and Conduct of A Study § 792.130 Conduct of a study. (a) The study shall be conducted in accordance with the protocol. (b) The test systems...

  4. 76 FR 27016 - Evaluating Test Procedures for Voting Systems

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-10

    ...-02] Evaluating Test Procedures for Voting Systems AGENCY: National Institute of Standards and... Assistance Commission for use by NIST in research to develop and assess NIST's test procedures for voting... develop and assess NIST test protocols for voting equipment. NIST research is designed to: (1) Develop...

  5. 106-17 Telemetry Standards Chapter 7 Packet Telemetry Downlink

    DTIC Science & Technology

    2017-07-31

    Acronyms IP Internet Protocol IPv4 Internet Protocol, Version 4 IPv6 Internet Protocol, Version 6 LLP low-latency PTDP MAC media access control...o 4’b0101: PT Internet Protocol (IP) Packet o 4’b0110: PT Chapter 24 TmNSMessage Packet o 4’b0111 – 4’b1111: Reserved • Fragment (bits 17 – 16...packet is defined as a free -running 12-bit counter. The PT test counter packet shall consist of one 12-bit word and shall be encoded as one 24-bit

  6. Space Link Extension Protocol Emulation for High-Throughput, High-Latency Network Connections

    NASA Technical Reports Server (NTRS)

    Tchorowski, Nicole; Murawski, Robert

    2014-01-01

    New space missions require higher data rates and new protocols to meet these requirements. These high data rate space communication links push the limitations of not only the space communication links, but of the ground communication networks and protocols which forward user data to remote ground stations (GS) for transmission. The Consultative Committee for Space Data Systems, (CCSDS) Space Link Extension (SLE) standard protocol is one protocol that has been proposed for use by the NASA Space Network (SN) Ground Segment Sustainment (SGSS) program. New protocol implementations must be carefully tested to ensure that they provide the required functionality, especially because of the remote nature of spacecraft. The SLE protocol standard has been tested in the NASA Glenn Research Center's SCENIC Emulation Lab in order to observe its operation under realistic network delay conditions. More specifically, the delay between then NASA Integrated Services Network (NISN) and spacecraft has been emulated. The round trip time (RTT) delay for the continental NISN network has been shown to be up to 120ms; as such the SLE protocol was tested with network delays ranging from 0ms to 200ms. Both a base network condition and an SLE connection were tested with these RTT delays, and the reaction of both network tests to the delay conditions were recorded. Throughput for both of these links was set at 1.2Gbps. The results will show that, in the presence of realistic network delay, the SLE link throughput is significantly reduced while the base network throughput however remained at the 1.2Gbps specification. The decrease in SLE throughput has been attributed to the implementation's use of blocking calls. The decrease in throughput is not acceptable for high data rate links, as the link requires constant data a flow in order for spacecraft and ground radios to stay synchronized, unless significant data is queued a the ground station. In cases where queuing the data is not an option, such as during real time transmissions, the SLE implementation cannot support high data rate communication.

  7. Critical issues with the in vivo comet assay: A report of the comet assay working group in the 6th International Workshop on Genotoxicity Testing (IWGT).

    PubMed

    Speit, Günter; Kojima, Hajime; Burlinson, Brian; Collins, Andrew R; Kasper, Peter; Plappert-Helbig, Ulla; Uno, Yoshifumi; Vasquez, Marie; Beevers, Carol; De Boeck, Marlies; Escobar, Patricia A; Kitamoto, Sachiko; Pant, Kamala; Pfuhler, Stefan; Tanaka, Jin; Levy, Dan D

    2015-05-01

    As a part of the 6th IWGT, an expert working group on the comet assay evaluated critical topics related to the use of the in vivo comet assay in regulatory genotoxicity testing. The areas covered were: identification of the domain of applicability and regulatory acceptance, identification of critical parameters of the protocol and attempts to standardize the assay, experience with combination and integration with other in vivo studies, demonstration of laboratory proficiency, sensitivity and power of the protocol used, use of different tissues, freezing of samples, and choice of appropriate measures of cytotoxicity. The standard protocol detects various types of DNA lesions but it does not detect all types of DNA damage. Modifications of the standard protocol may be used to detect additional types of specific DNA damage (e.g., cross-links, bulky adducts, oxidized bases). In addition, the working group identified critical parameters that should be carefully controlled and described in detail in every published study protocol. In vivo comet assay results are more reliable if they were obtained in laboratories that have demonstrated proficiency. This includes demonstration of adequate response to vehicle controls and an adequate response to a positive control for each tissue being examined. There was a general agreement that freezing of samples is an option but more data are needed in order to establish generally accepted protocols. With regard to tissue toxicity, the working group concluded that cytotoxicity could be a confounder of comet results. It is recommended to look at multiple parameters such as histopathological observations, organ-specific clinical chemistry as well as indicators of tissue inflammation to decide whether compound-specific toxicity might influence the result. The expert working group concluded that the alkaline in vivo comet assay is a mature test for the evaluation of genotoxicity and can be recommended to regulatory agencies for use. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. ISS and STS Commercial Off-the-Shelf Router Testing

    NASA Technical Reports Server (NTRS)

    Ivancie, William D.; Bell, Terry L.; Shell, Dan

    2002-01-01

    This report documents the results of testing performed with commercial off-the-shelf (COTS) routers and Internet Protocols (IPs) to determine if COTS equipment and IP could be utilized to upgrade NASA's current Space Transportation System (STS), the Shuttle, and the International Space Station communication infrastructure. Testing was performed by NASA Glenn Research Center (GRC) personnel within the Electronic Systems Test Laboratory (ESTE) with cooperation from the Mission Operations Directorate (MOD) Qualification and Utilization of Electronic System Technology (QUEST) personnel. The ESTE testing occurred between November 1 and 9, 2000. Additional testing was performed at NASA Glenn Research Center in a laboratory environment with equipment configured to emulate the STS. This report documents those tests and includes detailed test procedures, equipment interface requirements, test configurations and test results. The tests showed that a COTS router and standard Transmission Control Protocols and Internet Protocols (TCP/IP) could be used for both the Shuttle and the Space Station if near-error-free radio links are provided.

  9. Simultaneous validation of the SunTech CT40 automated blood pressure measurement device by the 1993 British Hypertension Society protocol and the Association for the Advancement of Medical Instrumentation/International Organization for Standardization 81060-2: 2013 standard.

    PubMed

    Polo Friz, Hernan; Punzi, Veronica; Petri, Francesco; Orlandi, Riccardo; Maggiolini, Daniele; Polo Friz, Melisa; Primitz, Laura; Vighi, Giuseppe

    2017-10-01

    This study aimed to perform a simultaneous, third-party, independent validation of the oscillometric SunTech CT40 device for blood pressure (BP) measurement, according to the 1993 protocol of the British Hypertension Society and the standard of the Association for the Advancement of Medical Instrumentation (AAMI)/the International Organization for Standardization (ISO) 81060-2:2013. Patient recruitment, study procedures, and data analysis followed the recommendations stated by the protocols. The study was approved by the institutional review board. A total of 94 participants were included, 52 (55.3%) women, mean±SD age: 63.1±18.0 years, mean±SD arm circumference: 35.0±9.0 cm. The average of observers' entry BPs was 146.9±37.2 mmHg for systolic blood pressure (SBP) and 82.2±22.1 mmHg for diastolic blood pressure (DBP). Differences between the standard measurement and the test device within 5, 10, and 15 mmHg, for the better observer, were 79.4, 96.5, and 100.0% for SBP and 82.6, 97.5, and 100.0% for DBP, respectively. The mean±SD differences between the readings obtained using the test device and those obtained by the observers (AAMI/ISO 81060-2:2013 standard criterion 1) were 0.3±5.0 mmHg (SBP) and -0.8±4.3 mmHg (DBP), and the mean±SD differences between average of reference readings and average of test device readings in each patient (criterion 2) were 0.3±3.9 and -0.8±3.5 mmHg for SBP and DBP, respectively. The CT40 BP device achieved A/A grade of the British Hypertension Society protocol and fulfilled the requirements (criteria 1 and 2) of the AAMI/ISO standard. CT40 can be recommended for BP measurement in adults.

  10. Implementing a Standardized Social Networks Testing Strategy in a Low HIV Prevalence Jurisdiction.

    PubMed

    Schumann, Casey; Kahn, Danielle; Broaddus, Michelle; Dougherty, Jacob; Elderbrook, Megan; Vergeront, James; Westergaard, Ryan

    2018-05-15

    Alternative HIV testing strategies are needed to engage individuals not reached by traditional clinical or non-clinical testing programs. A social networks recruitment strategy, in which people at risk for or living with HIV are enlisted and trained by community-based agencies to recruit individuals from their social, sexual, or drug-using networks for HIV testing, demonstrates higher positivity rates compared to other non-clinical recruitment strategies in some jurisdictions. During 2013-2015, a social networks testing protocol was implemented in Wisconsin to standardize an existing social networks testing program. Six community-based, non-clinical agencies with multiple sites throughout the state implemented the protocol over the 2-year period. Both quantitative and qualitative data were collected. The new positivity rate (0.49%) through social networks testing did not differ from that of traditional counseling, testing, and referral recruitment methods (0.48%). Although social networks testing did not yield a higher new positivity rate compared to other testing strategies, it proved to be successful at reaching high risk individuals who may not otherwise engage in HIV testing.

  11. Water Quality Standards for Coral Reef Protection | Science ...

    EPA Pesticide Factsheets

    The U.S. Clean Water Act provides a legal framework to protect coastal biological resources such as coral reefs, mangrove forests, and seagrass meadows from the damaging effects of human activities. Even though many resources are protected under this authority, water quality standards have not been effectively applied to coral reefs. The Environmental Protection Agency is promoting biocriteria and other water quality standards through collaborative development of bioassessment procedures, indicators and monitoring strategies. To support regulatory action, bioassessment indicators must be biologically meaningful, relevant to management, responsive to human disturbance, and relatively immune to natural variability. A rapid bioassessment protocol for reef-building stony corals was developed and tested for regulatory applicability. Preliminary testing in the Florida Keys found indicators had sufficient precision and provided information relevant to coral reef management. Sensitivity to human disturbance was demonstrated in the U.S. Virgin Islands for five of eight indicators tested. Once established, monitoring programs using these indicators can provide valuable, long-term records of coral condition and regulatory compliance. Development of a rapid bioassement protocol for reef-building stony corals was tested for regulatory applicability.

  12. 40 CFR 160.130 - Conduct of a study.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 24 2011-07-01 2011-07-01 false Conduct of a study. 160.130 Section... LABORATORY PRACTICE STANDARDS Protocol for and Conduct of a Study § 160.130 Conduct of a study. (a) The study... conformity with the protocol. (c) Specimens shall be identified by test system, study, nature, and date of...

  13. 40 CFR 160.130 - Conduct of a study.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Conduct of a study. 160.130 Section... LABORATORY PRACTICE STANDARDS Protocol for and Conduct of a Study § 160.130 Conduct of a study. (a) The study... conformity with the protocol. (c) Specimens shall be identified by test system, study, nature, and date of...

  14. 40 CFR 792.130 - Conduct of a study.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 31 2010-07-01 2010-07-01 true Conduct of a study. 792.130 Section 792... (CONTINUED) GOOD LABORATORY PRACTICE STANDARDS Protocol for and Conduct of A Study § 792.130 Conduct of a study. (a) The study shall be conducted in accordance with the protocol. (b) The test systems shall be...

  15. Standardized protocols for quality control of MRM-based plasma proteomic workflows.

    PubMed

    Percy, Andrew J; Chambers, Andrew G; Smith, Derek S; Borchers, Christoph H

    2013-01-04

    Mass spectrometry (MS)-based proteomics is rapidly emerging as a viable technology for the identification and quantitation of biological samples, such as human plasma--the most complex yet commonly employed biofluid in clinical analyses. The transition from a qualitative to quantitative science is required if proteomics is going to successfully make the transition to a clinically useful technique. MS, however, has been criticized for a lack of reproducibility and interlaboratory transferability. Currently, the MS and plasma proteomics communities lack standardized protocols and reagents to ensure that high-quality quantitative data can be accurately and precisely reproduced by laboratories across the world using different MS technologies. Toward addressing this issue, we have developed standard protocols for multiple reaction monitoring (MRM)-based assays with customized isotopically labeled internal standards for quality control of the sample preparation workflow and the MS platform in quantitative plasma proteomic analyses. The development of reference standards and their application to a single MS platform is discussed herein, along with the results from intralaboratory tests. The tests highlighted the importance of the reference standards in assessing the efficiency and reproducibility of the entire bottom-up proteomic workflow and revealed errors related to the sample preparation and performance quality and deficits of the MS and LC systems. Such evaluations are necessary if MRM-based quantitative plasma proteomics is to be used in verifying and validating putative disease biomarkers across different research laboratories and eventually in clinical laboratories.

  16. A new developmental toxicity test for pelagic fish using anchoveta (Engraulis ringens J.).

    PubMed

    Llanos-Rivera, A; Castro, L R; Silva, J; Bay-Schmith, E

    2009-07-01

    A series of six 96-h static bioassays were performed to validate the use of anchoveta (Engraulis ringens) embryos as test organisms for ecotoxicological studies. The standardization protocol utilized potassium dichromate (K(2)Cr(2)O(7)) as a reference toxicant and egg mortality as the endpoint. The results indicated that the mean sensitivity of anchoveta embryos to potassium dichromate was 156.1 mg L(-1) (range: 131-185 mg L(-1)). The statistical data analysis showed high homogeneity in LC50 values among bioassays (variation coefficient = 11.02%). These results demonstrated that the protocol and handling procedures implemented for the anchoveta embryo bioassays comply with international standards for intra-laboratory precision. After secondary treatment, an effluent from a modern Kraft pulp mill was tested for E. ringens embryo toxicity, finding no significant differences from the controls.

  17. Diagnostic and Therapeutic Knowledge and Practices in the Management of Congenital Syphilis by Pediatricians in Public Maternity Hospitals in Brazil.

    PubMed

    Dos Santos, Raquel Rodrigues; Niquini, Roberta Pereira; Bastos, Francisco Inácio; Domingues, Rosa Maria Soares Madeira

    2017-01-01

    The study aimed to assess conformity with Brazil's standard protocol for diagnostic and therapeutic practices in the management of congenital syphilis by pediatricians in public maternity hospitals. A cross-sectional study was conducted in 2015 with 41 pediatricians working in all the public maternity hospitals in Teresina, the capital of Piauí State, Northeast Brazil, through self-completed questionnaires. The study assessed the conformity of knowledge and practices according to the Brazilian Ministry of Health protocols. The study has made evident low access to training courses (54%) and insufficient knowledge of the case definition of congenital syphilis (42%) and rapid tests for syphilis (39%). Flaws were observed in the diagnostic workup and treatment of newborns. Requesting VDRL (88%) and correct treatment of neurosyphilis (88%) were the practices that showed the highest conformity with standard protocols. Low conformity with protocols leads to missed opportunities for identifying and adequately treating congenital syphilis. Based on the barriers identified in the study, better access to diagnostic and treatment protocols, improved recording on prenatal cards and hospital patient charts, availability of tests and medicines, and educational work with pregnant women should be urgently implemented, aiming to reverse the currently inadequate management of congenital syphilis and to curb its spread.

  18. A vascular laboratory protocol for improving and managing after-hours suspected acute deep venous thrombosis.

    PubMed

    Martin, Angela H; Eckert, George; Lemmon, Gary W; Sawchuk, Alan; Dalsing, Michael C

    2014-04-01

    This study reviews the clinical and workforce impact of a suggested protocol designed for the management of suspected acute deep venous thrombosis (DVT) in patients seen after standard vascular laboratory business hours. The protocol included the use of Wells score, D-dimer and a single dose of therapeutic anticoagulant to defer venous duplex ultrasound (VDU) testing until routine business hours unless contraindicated. Information was collected on medical history, physical exam and the timing of any diagnostic studies and treatment provided. Over 15% of studies done after-hours were deemed unnecessary by our protocol and in every individual the results were negative for an acute DVT. There were no adverse events from a one-time dose of anticoagulant. Limiting emergency VDU coverage to evaluate for acute DVT based on a management protocol can eliminate unnecessary after-hours VDU testing without having a negative impact on patient care.

  19. Reliability and Validity of the Standing Heel-Rise Test

    ERIC Educational Resources Information Center

    Yocum, Allison; McCoy, Sarah Westcott; Bjornson, Kristie F.; Mullens, Pamela; Burton, Gay Naganuma

    2010-01-01

    A standardized protocol for a pediatric heel-rise test was developed and reliability and validity are reported. Fifty-seven children developing typically (CDT) and 34 children with plantar flexion weakness performed three tests: unilateral heel rise, vertical jump, and force measurement using handheld dynamometry. Intraclass correlation…

  20. Acute effects of various weighted bat warm-up protocols on bat velocity.

    PubMed

    Reyes, G Francis; Dolny, Dennis

    2009-10-01

    Although research has provided evidence of increased muscular performance following a facilitation set of resistance exercise, this has not been established for use prior to measuring baseball bat velocity. The purpose of this study was to determine the effectiveness of selected weighted bat warm-up protocols to enhance bat velocity in collegiate baseball players. Nineteen collegiate baseball players (age = 20.15 +/- 1.46 years) were tested for upper-body strength by a 3-repetition maximum (RM) bench press (mean = 97.98 +/- 14.54 kg) and mean bat velocity. Nine weighted bat warm-up protocols, utilizing 3 weighted bats (light = 794 g; standard = 850 g; heavy = 1,531 g) were swung in 3 sets of 6 repetitions in different orders. A control trial involved the warm-up protocol utilizing only the standard bat. Pearson product correlation revealed a significant relationship between 3RM strength and pretest bat velocity (r = 0.51, p = 0.01). Repeated measures analysis of variance (ANOVA) revealed no significant treatment effects of warm-up protocol on bat velocity. However, the order of standard, light, heavy bat sequence resulted in the greatest increase in bat velocity (+6.03%). These results suggest that upper-body muscle strength influences bat velocity. It appears that the standard, light, heavy warm-up order may provide the greatest benefit to increase subsequent bat velocity and may warrant use in game situations.

  1. Multiplex Droplet Digital PCR Protocols for Quantification of GM Maize Events.

    PubMed

    Dobnik, David; Spilsberg, Bjørn; Bogožalec Košir, Alexandra; Štebih, Dejan; Morisset, Dany; Holst-Jensen, Arne; Žel, Jana

    2018-01-01

    The standard-curve based simplex quantitative polymerase chain reaction (qPCR) has been the gold standard for DNA target quantification for more than a decade. The large and growing number of individual analyses needed to test for genetically modified organisms (GMOs) is reducing the cost-effectiveness of qPCR. Droplet digital PCR (ddPCR) enables absolute quantification without standard curves, avoids the amplification efficiency bias observed with qPCR, allows more accurate estimations at low target copy numbers and, in combination with multiplexing, significantly improves cost efficiency. Here we describe two protocols for multiplex quantification of GM maize events: (1) nondiscriminating, with multiplex quantification of targets as a group (12 GM maize lines) and (2) discriminating, with multiplex quantification of individual targets (events). The first enables the quantification of twelve European Union authorized GM maize events as a group with only two assays, but does not permit determination of the individual events present. The second protocol enables the quantification of four individual targets (three GM events and one endogene) in a single reaction. Both protocols can be modified for quantification of any other DNA target.

  2. Manitoba Schools Fitness 1989.

    ERIC Educational Resources Information Center

    Manitoba Dept. of Education, Winnipeg.

    This manual outlines physical fitness tests that may be used in the schools. The tests are based on criterion standards which indicate the levels of achievement at which health risk factors may be reduced. Test theory, protocols, and criterion charts are presented for: (1) muscle strength and endurance, (2) body composition, (3) flexibility, and…

  3. Comparison of the Liaison® Calprotectin kit with a well established point of care test (Quantum Blue - Bühlmann-Alere®) in terms of analytical performances and ability to detect relapses amongst a Crohn population in follow-up.

    PubMed

    Delefortrie, Quentin; Schatt, Patricia; Grimmelprez, Alexandre; Gohy, Patrick; Deltour, Didier; Collard, Geneviève; Vankerkhoven, Patrick

    2016-02-01

    Although colonoscopy associated with histopathological sampling remains the gold standard in the diagnostic and follow-up of inflammatory bowel disease (IBD), calprotectin is becoming an essential biomarker in gastroenterology. The aim of this work is to compare a newly developed kit (Liaison® Calprotectin - Diasorin®) and its two distinct extraction protocols (weighing and extraction device protocol) with a well established point of care test (Quantum Blue® - Bühlmann-Alere®) in terms of analytical performances and ability to detect relapses amongst a Crohn's population in follow-up. Stool specimens were collected over a six month period and were composed of control and Crohn's patients. Amongst the Crohn's population disease activity (active vs quiescent) was evaluated by gastroenterologists. A significant difference was found between all three procedures in terms of calprotectin measurements (weighing protocol=30.3μg/g (median); stool extraction device protocol=36.9μg/g (median); Quantum Blue® (median)=63; Friedman test, P value=0.05). However, a good correlation was found between both extraction methods coupled with the Liaison® analyzer and between the Quantum Blue® (weighing protocol/extraction device protocol Rs=0.844, P=0.01; Quantum Blue®/extraction device protocol Rs=0.708, P=0.01; Quantum Blue®/weighing protocol, Rs=0.808, P=0.01). Finally, optimal cut-offs (and associated negative predictive values - NPV) for detecting relapses were in accordance with above results (Quantum Blue® 183.5μg/g and NPV of 100%>extraction device protocol+Liaison® analyzer 124.5μg/g and NPV of 93.5%>weighing protocol+Liaison® analyzer 106.5μg/g and NPV of 95%). Although all three methods correlated well and had relatively good NPV in terms of detecting relapses amongst a Crohn's population in follow-up, the lack of any international standard is the origin of different optimal cut-offs between the three procedures. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  4. EVA Human Health and Performance Benchmarking Study Overview and Development of a Microgravity Protocol

    NASA Technical Reports Server (NTRS)

    Norcross, Jason; Jarvis, Sarah; Bekdash, Omar; Cupples, Scott; Abercromby, Andrew

    2017-01-01

    The primary objective of this study is to develop a protocol to reliably characterize human health and performance metrics for individuals working inside various EVA suits under realistic spaceflight conditions. Expected results and methodologies developed during this study will provide the baseline benchmarking data and protocols with which future EVA suits and suit configurations (e.g., varied pressure, mass, center of gravity [CG]) and different test subject populations (e.g., deconditioned crewmembers) may be reliably assessed and compared. Results may also be used, in conjunction with subsequent testing, to inform fitness-for-duty standards, as well as design requirements and operations concepts for future EVA suits and other exploration systems.

  5. Measures of fish behavior as indicators of sublethal toxicosis during standard toxicity tests

    USGS Publications Warehouse

    Little, E.E.; DeLonay, A.J.

    1996-01-01

    Behavioral functions essential for growth and survival can be dramatically altered by sublethal exposure to toxicants. Measures of these behavioral responses are effective in detecting adverse effects of sublethal contaminant exposure. Behavioral responses of fishes can be qualitatively and quantitatively evaluated during routine toxicity tests. At selected intervals of exposure, qualitative evaluations are accomplished through direct observations, whereas video recordings are used for quantitative evaluations. Standardized procedures for behavioral evaluation are readily applicable to different fish species and provide rapid, sensitive, and ecologically relevant assessments of sublethal exposure. The methods are readily applied to standardized test protocols.

  6. Disinfection protocols for necropsy equipment in rabies laboratories: Safety of personnel and diagnostic outcome.

    PubMed

    Aiello, Roberta; Zecchin, Barbara; Tiozzo Caenazzo, Silvia; Cattoli, Giovanni; De Benedictis, Paola

    2016-08-01

    In the last decades, molecular techniques have gradually been adopted for the rapid confirmation of results obtained through gold standard methods. However, international organisations discourage their use in routine laboratory investigations for rabies post-mortem diagnosis, as they may lead to false positive results due to cross-contamination. Cleaning and disinfection are essential to prevent cross-contamination of samples in the laboratory environment. The present study evaluated the efficacy of selected disinfectants on rabies-contaminated necropsy equipment under organic challenge using a carrier-based test. The occurrence of detectable Rabies virus (RABV) antigen, viable virus and RNA was assessed through the gold standard Fluorescent Antibody Test, the Rabies Tissue Culture Infection Test and molecular techniques, respectively. None of the tested disinfectants proved to be effective under label conditions. Off label disinfection protocols were found effective for oxidizing agents and phenolic, only. Biguanide and quaternary ammonium compound were both ineffective under all tested conditions. Overall, discordant results were obtained when different diagnostic tests were compared, which means that in the presence of organic contamination common disinfectants may not be effective enough on viable RABV or RNA. Our results indicate that an effective disinfection protocol should be carefully validated to guarantee staff safety and reliability of results. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  7. A Performance Evaluation of NACK-Oriented Protocols as the Foundation of Reliable Delay- Tolerant Networking Convergence Layers

    NASA Technical Reports Server (NTRS)

    Iannicca, Dennis; Hylton, Alan; Ishac, Joseph

    2012-01-01

    Delay-Tolerant Networking (DTN) is an active area of research in the space communications community. DTN uses a standard layered approach with the Bundle Protocol operating on top of transport layer protocols known as convergence layers that actually transmit the data between nodes. Several different common transport layer protocols have been implemented as convergence layers in DTN implementations including User Datagram Protocol (UDP), Transmission Control Protocol (TCP), and Licklider Transmission Protocol (LTP). The purpose of this paper is to evaluate several stand-alone implementations of negative-acknowledgment based transport layer protocols to determine how they perform in a variety of different link conditions. The transport protocols chosen for this evaluation include Consultative Committee for Space Data Systems (CCSDS) File Delivery Protocol (CFDP), Licklider Transmission Protocol (LTP), NACK-Oriented Reliable Multicast (NORM), and Saratoga. The test parameters that the protocols were subjected to are characteristic of common communications links ranging from terrestrial to cis-lunar and apply different levels of delay, line rate, and error.

  8. Exosome-like vesicles in uterine aspirates: a comparison of ultracentrifugation-based isolation protocols.

    PubMed

    Campoy, Irene; Lanau, Lucia; Altadill, Tatiana; Sequeiros, Tamara; Cabrera, Silvia; Cubo-Abert, Montserrat; Pérez-Benavente, Assumpción; Garcia, Angel; Borrós, Salvador; Santamaria, Anna; Ponce, Jordi; Matias-Guiu, Xavier; Reventós, Jaume; Gil-Moreno, Antonio; Rigau, Marina; Colas, Eva

    2016-06-18

    Uterine aspirates are used in the diagnostic process of endometrial disorders, yet further applications could emerge if its complex milieu was simplified. Exosome-like vesicles isolated from uterine aspirates could become an attractive source of biomarkers, but there is a need to standardize isolation protocols. The objective of the study was to determine whether exosome-like vesicles exist in the fluid fraction of uterine aspirates and to compare protocols for their isolation, characterization, and analysis. We collected uterine aspirates from 39 pre-menopausal women suffering from benign gynecological diseases. The fluid fraction of 27 of those aspirates were pooled and split into equal volumes to evaluate three differential centrifugation-based procedures: (1) a standard protocol, (2) a filtration protocol, and (3) a sucrose cushion protocol. Characterization of isolated vesicles was assessed by electron microscopy, nanoparticle tracking analysis and immunoblot. Specifically for RNA material, we evaluate the effect of sonication and RNase A treatment at different steps of the protocol. We finally confirmed the efficiency of the selected methods in non-pooled samples. All protocols were useful to isolate exosome-like vesicles. However, the Standard procedure was the best performing protocol to isolate exosome-like vesicles from uterine aspirates: nanoparticle tracking analysis revealed a higher concentration of vesicles with a mode of 135 ± 5 nm, and immunoblot showed a higher expression of exosome-related markers (CD9, CD63, and CD81) thus verifying an enrichment in this type of vesicles. RNA contained in exosome-like vesicles was successfully extracted with no sonication treatment and exogenous nucleic acids digestion with RNaseA, allowing the analysis of the specific inner cargo by Real-Time qPCR. We confirmed the existence of exosome-like vesicles in the fluid fraction of uterine aspirates. They were successfully isolated by differential centrifugation giving sufficient proteomic and transcriptomic material for further analyses. The Standard protocol was the best performing procedure since the other two tested protocols did not ameliorate neither yield nor purity of exosome-like vesicles. This study contributes to establishing the basis for future comparative studies to foster the field of biomarker research in gynecology.

  9. Data Acceptance Criteria for Standardized Human-Associated Fecal Source Identification Quantitative Real-Time PCR Methods.

    PubMed

    Shanks, Orin C; Kelty, Catherine A; Oshiro, Robin; Haugland, Richard A; Madi, Tania; Brooks, Lauren; Field, Katharine G; Sivaganesan, Mano

    2016-05-01

    There is growing interest in the application of human-associated fecal source identification quantitative real-time PCR (qPCR) technologies for water quality management. The transition from a research tool to a standardized protocol requires a high degree of confidence in data quality across laboratories. Data quality is typically determined through a series of specifications that ensure good experimental practice and the absence of bias in the results due to DNA isolation and amplification interferences. However, there is currently a lack of consensus on how best to evaluate and interpret human fecal source identification qPCR experiments. This is, in part, due to the lack of standardized protocols and information on interlaboratory variability under conditions for data acceptance. The aim of this study is to provide users and reviewers with a complete series of conditions for data acceptance derived from a multiple laboratory data set using standardized procedures. To establish these benchmarks, data from HF183/BacR287 and HumM2 human-associated qPCR methods were generated across 14 laboratories. Each laboratory followed a standardized protocol utilizing the same lot of reference DNA materials, DNA isolation kits, amplification reagents, and test samples to generate comparable data. After removal of outliers, a nested analysis of variance (ANOVA) was used to establish proficiency metrics that include lab-to-lab, replicate testing within a lab, and random error for amplification inhibition and sample processing controls. Other data acceptance measurements included extraneous DNA contamination assessments (no-template and extraction blank controls) and calibration model performance (correlation coefficient, amplification efficiency, and lower limit of quantification). To demonstrate the implementation of the proposed standardized protocols and data acceptance criteria, comparable data from two additional laboratories were reviewed. The data acceptance criteria proposed in this study should help scientists, managers, reviewers, and the public evaluate the technical quality of future findings against an established benchmark. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  10. How to Apply for Protection Time Graphic

    EPA Pesticide Factsheets

    We will review insect repellent products that voluntarily apply to use the repellency awareness graphic to ensure that their scientific data meet current testing protocols and standard evaluation processes.

  11. Manual muscle testing: a method of measuring extremity muscle strength applied to critically ill patients.

    PubMed

    Ciesla, Nancy; Dinglas, Victor; Fan, Eddy; Kho, Michelle; Kuramoto, Jill; Needham, Dale

    2011-04-12

    Survivors of acute respiratory distress syndrome (ARDS) and other causes of critical illness often have generalized weakness, reduced exercise tolerance, and persistent nerve and muscle impairments after hospital discharge. Using an explicit protocol with a structured approach to training and quality assurance of research staff, manual muscle testing (MMT) is a highly reliable method for assessing strength, using a standardized clinical examination, for patients following ARDS, and can be completed with mechanically ventilated patients who can tolerate sitting upright in bed and are able to follow two-step commands. (7, 8) This video demonstrates a protocol for MMT, which has been taught to ≥ 43 research staff who have performed >800 assessments on >280 ARDS survivors. Modifications for the bedridden patient are included. Each muscle is tested with specific techniques for positioning, stabilization, resistance, and palpation for each score of the 6-point ordinal Medical Research Council scale. Three upper and three lower extremity muscles are graded in this protocol: shoulder abduction, elbow flexion, wrist extension, hip flexion, knee extension, and ankle dorsiflexion. These muscles were chosen based on the standard approach for evaluating patients for ICU-acquired weakness used in prior publications. (1,2).

  12. Development of Test Protocols for International Space Station Particulate Filters

    NASA Technical Reports Server (NTRS)

    Vijayakumar, R.; Green, Robert D.; Agui, Juan H.

    2015-01-01

    Air quality control on the International Space Station (ISS) is a vital requirement for maintaining a clean environment for the crew and the hardware. This becomes a serious challenge in pressurized space compartments since no outside air ventilation is possible, and a larger particulate load is imposed on the filtration system due to lack of gravitational settling. The ISS Environmental Control and Life Support System (ECLSS) uses a filtration system that has been in use for over 14 years and has proven to meet this challenge. The heart of this system is a traditional High-Efficiency Particulate Air (HEPA) filter configured to interface with the rest of the life support elements and provide effective cabin filtration. The filter element for this system has a non-standard cross-section with a length-to-width ratio (LW) of 6.6. A filter test setup was designed and built to meet industry testing standards. A CFD analysis was performed to initially determine the optimal duct geometry and flow configuration. Both a screen and flow straighter were added to the test duct design to improve flow uniformity and face velocity profiles were subsequently measured to confirm. Flow quality and aerosol mixing assessments show that the duct flow is satisfactory for the intended leak testing. Preliminary leak testing was performed on two different ISS filters, one with known perforations and one with limited use, and results confirmed that the testing methods and photometer instrument are sensitive enough to detect and locate compromised sections of an ISS BFE.Given the engineering constraints in designing spacecraft life support systems, it is anticipated that non-industry standard filters will be required in future designs. This work is focused on developing test protocols for testing the ISS BFE filters, but the methodology is general enough to be extended to other present and future spacecraft filters. These techniques for characterizing the test duct and perform leak testing can be applied to conducting acceptance testing and inventory testing for future manned exploration programs with air revitalization filtration needs, possibly even for in-situ filter element integrity testing for extensively long-duration missions. We plan to address the unique needs for test protocols for crewed spacecraft particulate filters by preparing the initial version of a standard, to be documented as a NASA Technical Memorandum (TM).

  13. Qualification of a precise and easy-to-handle sweat casting imprint method for the prediction and quantification of anti-perspirant efficacy.

    PubMed

    Keyhani, R; Scheede, S; Thielecke, I; Wenck, H; Schmucker, R; Schreiner, V; Ennen, J; Herpens, A

    2009-06-01

    A time- and cost-effective sweat casting method using the forearm as test site to assess the efficacy of several anti-perspirant formulations with a low number of test subjects has been evaluated and qualified. The imprint sweat casting method is based on a 2-component silcone-imprint technique to measure the efficacy of more than eight products in parallel with the same test subject. In studies using aluminum chlorohydrate (ACH) formulations as test anti-perspirants, a clear-cut correlation could be demonstrated between sweat gland activities measured by the imprint method and gravimetric measurement of sweat gland activities. Concentration-dependent inhibition of sweat gland activity could be observed with the imprint technique up to an ACH concentration of 15%, and all formulations containing 2% ACH or above resulted in statistically significant reduction of sweat gland activity (P < 0.001) when compared with untreated control areas. Furthermore, the SDs of individual studies using the imprint technique were in a range of +/-20% of sweat gland activity, which can be regarded rather low for in vivo measurements of a complex process like sweat secretion. A group-wise comparison between the measurements of anti-perspirant activity as determined by the imprint protocol and the Food and Drug Administration (FDA) Guideline compliant gravimetric hot-room protocol revealed that the test results for anti-perspirant activity obtained with the imprint protocol are similar to those obtained with the hot-room protocol. Moreover, the data generated with the imprint protocol have a high predictive value for the outcome of a later guideline-compliant hot-room test. As the imprint casting method tends to be a little more sensitive for formulations with low anti-perspirant activity, and seems to be associated with less interassay variability than the standard gravimetric hot-room test, the imprint casting method may select products which later fail to pass the standard gravimetric hot-room test. Meanwhile the imprint sweat casting has proven to be a robust method useful to support efficacy-oriented product development. Therefore, in later stages of utilization it might even evolve into an efficient claim substantiation tool.

  14. Performance of a docking/molecular dynamics protocol for virtual screening of nutlin-class inhibitors of Mdmx.

    PubMed

    Bharatham, Nagakumar; Finch, Kristin E; Min, Jaeki; Mayasundari, Anand; Dyer, Michael A; Guy, R Kiplin; Bashford, Donald

    2017-06-01

    A virtual screening protocol involving docking and molecular dynamics has been tested against the results of fluorescence polarization assays testing the potency of a series of compounds of the nutlin class for inhibition of the interaction between p53 and Mdmx, an interaction identified as a driver of certain cancers. The protocol uses a standard docking method (AutoDock) with a cutoff based on the AutoDock score (ADscore), followed by molecular dynamics simulation with a cutoff based on root-mean-square-deviation (RMSD) from the docked pose. An analysis of the experimental and computational results shows modest performance of ADscore alone, but dramatically improved performance when RMSD is also used. Published by Elsevier Inc.

  15. Computer simulation of fibrillation threshold measurements and electrophysiologic testing procedures

    NASA Technical Reports Server (NTRS)

    Grumbach, M. P.; Saxberg, B. E.; Cohen, R. J.

    1987-01-01

    A finite element model of cardiac conduction was used to simulate two experimental protocols: 1) fibrillation threshold measurements and 2) clinical electrophysiologic (EP) testing procedures. The model consisted of a cylindrical lattice whose properties were determined by four parameters: element length, conduction velocity, mean refractory period, and standard deviation of refractory periods. Different stimulation patterns were applied to the lattice under a given set of lattice parameter values and the response of the model was observed through a simulated electrocardiogram. The studies confirm that the model can account for observations made in experimental fibrillation threshold measurements and in clinical EP testing protocols.

  16. Architecture of a general purpose embedded Slow-Control Adapter ASIC for future high-energy physics experiments

    NASA Astrophysics Data System (ADS)

    Gabrielli, Alessandro; Loddo, Flavio; Ranieri, Antonio; De Robertis, Giuseppe

    2008-10-01

    This work is aimed at defining the architecture of a new digital ASIC, namely Slow-Control Adapter (SCA), which will be designed in a commercial 130-nm CMOS technology. This chip will be embedded within a high-speed data acquisition optical link (GBT) to control and monitor the front-end electronics in future high-energy physics experiments. The GBT link provides a transparent transport layer between the SCA and control electronics in the counting room. The proposed SCA supports a variety of common bus protocols to interface with end-user general-purpose electronics. Between the GBT and the SCA a standard 100 Mb/s IEEE-802.3 compatible protocol will be implemented. This standard protocol allows off-line tests of the prototypes using commercial components that support the same standard. The project is justified because embedded applications in modern large HEP experiments require particular care to assure the lowest possible power consumption, still offering the highest reliability demanded by very large particle detectors.

  17. Standardization of Nanoparticle Characterization: Methods for Testing Properties, Stability, and Functionality of Edible Nanoparticles.

    PubMed

    McClements, Jake; McClements, David Julian

    2016-06-10

    There has been a rapid increase in the fabrication of various kinds of edible nanoparticles for oral delivery of bioactive agents, such as those constructed from proteins, carbohydrates, lipids, and/or minerals. It is currently difficult to compare the relative advantages and disadvantages of different kinds of nanoparticle-based delivery systems because researchers use different analytical instruments and protocols to characterize them. In this paper, we briefly review the various analytical methods available for characterizing the properties of edible nanoparticles, such as composition, morphology, size, charge, physical state, and stability. This information is then used to propose a number of standardized protocols for characterizing nanoparticle properties, for evaluating their stability to environmental stresses, and for predicting their biological fate. Implementation of these protocols would facilitate comparison of the performance of nanoparticles under standardized conditions, which would facilitate the rational selection of nanoparticle-based delivery systems for different applications in the food, health care, and pharmaceutical industries.

  18. Meta-analysis of toxicity and teratogenicity of 133 chemicals from zebrafish developmental toxicity studies

    EPA Science Inventory

    Zebrafish developmental toxicity testing is an emerging field, which faces considerable challenges regarding data meta-analysis and the establishment of standardized test protocols. Here, we present an initial correlation study on toxicity of 133 chemicals based on data in the li...

  19. Spray drift reduction evaluations of spray nozzles using a standardized testing protocol

    USDA-ARS?s Scientific Manuscript database

    The development and testing of drift reduction technologies has come to the forefront of application research in the past few years in the United States. Drift reduction technologies (DRTs) can be spray nozzles, sprayer modifications, spray delivery assistance, spray property modifiers (adjuvants),...

  20. Standard Test Procedures for Evaluating Various Leak Detection Methods

    EPA Pesticide Factsheets

    Learn about protocols that testers could use to demonstrate that an individual release detection equipment type could meet the performance requirements noted in the federal UST requirements for detecting leaks.

  1. Reinforcing Abstinence and Treatment Participation among Offenders in a Drug Diversion Program: Are Vouchers Effective?

    PubMed Central

    Hall, Elizabeth A.; Prendergast, Michael L.; Roll, John M.; Warda, Umme

    2010-01-01

    This study assessed a 26-week voucher-based intervention to reinforce abstinence and participation in treatment-related activities among substance-abusing offenders court referred to outpatient treatment under drug diversion legislation (California's Substance Abuse and Crime Prevention Act). Standard treatment consisted of criminal justice supervision and an evidence-based model for treating stimulant abuse. Participants were randomly assigned to four groups, standard treatment (ST) only, ST plus vouchers for testing negative, ST plus vouchers for performing treatment plan activities, and ST plus vouchers for testing negative and/or performing treatment plan activities. Results indicate that voucher-based reinforcement of negative urines and of treatment plan tasks (using a flat reinforcement schedule) showed no statistically significant effects on measures of retention or drug use relative to the standard treatment protocol. It is likely that criminal justice contingencies had a stronger impact on participants' treatment retention and drug use than the relatively low-value vouchers awarded as part of the treatment protocol. PMID:20463918

  2. Validation of the Artsana CSI 610 automated blood pressure monitor in adults according to the International Protocol of the European Society of Hypertension.

    PubMed

    Pini, Claudio; Pastori, Marco; Baccheschi, Jordan; Omboni, Stefano; Parati, Gianfranco

    2007-06-01

    There is evidence that blood pressure measurement outside the doctor's office can provide valuable information for the diagnostic evaluation of hypertensive patients and for monitoring their response to treatment. Home blood pressure monitoring devices have a major role in this setting, provided that their accuracy in measuring blood pressure is demonstrated by validation studies. This study aimed at verifying whether the automatic electronic oscillometric blood pressure measuring device Artsana CSI 610 complied with the standard of accuracy indicated by the ESH International Protocol. Sequential measurements of systolic and diastolic blood pressure were obtained in 33 participants using the mercury sphygmomanometer (two observers) and the test device (one supervisor). A standard adult cuff was always employed during the study. According to the ESH validation protocol, 99 couples of test device and reference blood pressure measurements were obtained during the two phases of the study (three pairs for each of the 33 participants). The Artsana CSI 610 device successfully passed phase 1 of study validation with the number of absolute differences between test and reference device never <35 within 5 mmHg and never <40 within 10 and 15 mmHg. The test device also passed phase 2 of the validation study with a mean (+/-SD) device-observer difference of -1.4+/-4.8 mmHg for systolic and -0.9+/-3.5 mmHg for diastolic blood pressure. According to the results of the validation study on the basis of the ESH International Protocol, the Artsana CSI 610 can be recommended for clinical use in adults.

  3. College of American Pathologists Cancer Protocols: Optimizing Format for Accuracy and Efficiency.

    PubMed

    Strickland-Marmol, Leah B; Muro-Cacho, Carlos A; Barnett, Scott D; Banas, Matthew R; Foulis, Philip R

    2016-06-01

    -The data in College of American Pathologists cancer protocols have to be presented effectively to health care providers. There is no consensus on the format of those protocols, resulting in various designs among pathologists. Cancer protocols are independently created by site-specific experts, so there is inconsistent wording and repetition of data. This lack of standardization can be confusing and may lead to interpretation errors. -To define a synopsis format that is effective in delivering essential pathologic information and to evaluate the aesthetic appeal and the impact of varying format styles on the speed and accuracy of data extraction. -We queried individuals from several health care backgrounds using varying formats of the fallopian tube protocol of the College of American Pathologists without content modification to investigate their aesthetic appeal, accuracy, efficiency, and readability/complexity. Descriptive statistics, an item difficulty index, and 3 tests of readability were used. -Columned formats were aesthetically more appealing than justified formats (P < .001) and were associated with greater accuracy and efficiency. Incorrect assumptions were made about items not included in the protocol. Uniform wording and short sentences were associated with better performance by participants. -Based on these data, we propose standardized protocol formats for cancer resections of the fallopian tube and the more-familiar colon, employing headers, short phrases, and uniform terminology. This template can be easily and minimally modified for other sites, standardizing format and verbiage and increasing user accuracy and efficiency. Principles of human factors engineering should be considered in the display of patient data.

  4. A status review of photovoltaic power conversion equipment reliability, safety, and quality assurance protocols

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hacke, Peter; Lokanath, Sumanth; Williams, Paul

    Data indicate that the inverter is the element of the photovoltaic plant that has the highest number of service calls and the greatest operation and maintenance cost burden. This paper describes the projects and relevant background needed in developing design qualification standards that would serve to establish a minimum level of reliability, along with a review of photovoltaic inverter quality and safety standards, most of which are in their infancy. We compare stresses and levels for accelerated testing of inverters proposed in the standard drafts, and those proposed by manufacturers and purchasers of inverters. We also review bases for themore » methods, stress types, and stress levels for durability testing of key inverter components. Many of the test protocols appear to need more comprehensive inclusion of stress factors existing in the natural environment such as wind driven rain, dust, and grid disturbances. Further understanding of how temperature, humidity ingress, and voltage bias affect the inverters and their components is also required. We provide data indicating inconsistent quality of the inverters and the durability of components leading to greater cost for the photovoltaic plant operator. Accordingly, the recommendation for data collection within quality standards for obtaining cost of ownership metrics is made. Design validation testing using realistic operation, environmental, and connection conditions, including under end-use field conditions with feedback for continuous improvement is recommended for inclusion within a quality standard.« less

  5. A status review of photovoltaic power conversion equipment reliability, safety, and quality assurance protocols

    DOE PAGES

    Hacke, Peter; Lokanath, Sumanth; Williams, Paul; ...

    2017-10-10

    Data indicate that the inverter is the element of the photovoltaic plant that has the highest number of service calls and the greatest operation and maintenance cost burden. This paper describes the projects and relevant background needed in developing design qualification standards that would serve to establish a minimum level of reliability, along with a review of photovoltaic inverter quality and safety standards, most of which are in their infancy. We compare stresses and levels for accelerated testing of inverters proposed in the standard drafts, and those proposed by manufacturers and purchasers of inverters. We also review bases for themore » methods, stress types, and stress levels for durability testing of key inverter components. Many of the test protocols appear to need more comprehensive inclusion of stress factors existing in the natural environment such as wind driven rain, dust, and grid disturbances. Further understanding of how temperature, humidity ingress, and voltage bias affect the inverters and their components is also required. We provide data indicating inconsistent quality of the inverters and the durability of components leading to greater cost for the photovoltaic plant operator. Accordingly, the recommendation for data collection within quality standards for obtaining cost of ownership metrics is made. Design validation testing using realistic operation, environmental, and connection conditions, including under end-use field conditions with feedback for continuous improvement is recommended for inclusion within a quality standard.« less

  6. A practical way to estimate retail tobacco sales violation rates more accurately.

    PubMed

    Levinson, Arnold H; Patnaik, Jennifer L

    2013-11-01

    U.S. states annually estimate retailer propensity to sell adolescents cigarettes, which is a violation of law, by staging a single purchase attempt among a random sample of tobacco businesses. The accuracy of single-visit estimates is unknown. We examined this question using a novel test-retest protocol. Supervised minors attempted to purchase cigarettes at all retail tobacco businesses located in 3 Colorado counties. The attempts observed federal standards: Minors were aged 15-16 years, were nonsmokers, and were free of visible tattoos and piercings, and were allowed to enter stores alone or in pairs to purchase a small item while asking for cigarettes and to show or not show genuine identification (ID, e.g., driver's license). Unlike federal standards, stores received a second purchase attempt within a few days unless minors were firmly told not to return. Separate violation rates were calculated for first visits, second visits, and either visit. Eleven minors attempted to purchase cigarettes 1,079 times from 671 retail businesses. One sixth of first visits (16.8%) resulted in a violation; the rate was similar for second visits (15.7%). Considering either visit, 25.3% of businesses failed the test. Factors predictive of violation were whether clerks asked for ID, whether the clerks closely examined IDs, and whether minors included snacks or soft drinks in cigarette purchase attempts. A test-retest protocol for estimating underage cigarette sales detected half again as many businesses in violation as the federally approved one-test protocol. Federal policy makers should consider using the test-retest protocol to increase accuracy and awareness of widespread adolescent access to cigarettes through retail businesses.

  7. Developing Ubiquitous Sensor Network Platform Using Internet of Things: Application in Precision Agriculture.

    PubMed

    Ferrández-Pastor, Francisco Javier; García-Chamizo, Juan Manuel; Nieto-Hidalgo, Mario; Mora-Pascual, Jerónimo; Mora-Martínez, José

    2016-07-22

    The application of Information Technologies into Precision Agriculture methods has clear benefits. Precision Agriculture optimises production efficiency, increases quality, minimises environmental impact and reduces the use of resources (energy, water); however, there are different barriers that have delayed its wide development. Some of these main barriers are expensive equipment, the difficulty to operate and maintain and the standard for sensor networks are still under development. Nowadays, new technological development in embedded devices (hardware and communication protocols), the evolution of Internet technologies (Internet of Things) and ubiquitous computing (Ubiquitous Sensor Networks) allow developing less expensive systems, easier to control, install and maintain, using standard protocols with low-power consumption. This work develops and test a low-cost sensor/actuator network platform, based in Internet of Things, integrating machine-to-machine and human-machine-interface protocols. Edge computing uses this multi-protocol approach to develop control processes on Precision Agriculture scenarios. A greenhouse with hydroponic crop production was developed and tested using Ubiquitous Sensor Network monitoring and edge control on Internet of Things paradigm. The experimental results showed that the Internet technologies and Smart Object Communication Patterns can be combined to encourage development of Precision Agriculture. They demonstrated added benefits (cost, energy, smart developing, acceptance by agricultural specialists) when a project is launched.

  8. Developing Ubiquitous Sensor Network Platform Using Internet of Things: Application in Precision Agriculture

    PubMed Central

    Ferrández-Pastor, Francisco Javier; García-Chamizo, Juan Manuel; Nieto-Hidalgo, Mario; Mora-Pascual, Jerónimo; Mora-Martínez, José

    2016-01-01

    The application of Information Technologies into Precision Agriculture methods has clear benefits. Precision Agriculture optimises production efficiency, increases quality, minimises environmental impact and reduces the use of resources (energy, water); however, there are different barriers that have delayed its wide development. Some of these main barriers are expensive equipment, the difficulty to operate and maintain and the standard for sensor networks are still under development. Nowadays, new technological development in embedded devices (hardware and communication protocols), the evolution of Internet technologies (Internet of Things) and ubiquitous computing (Ubiquitous Sensor Networks) allow developing less expensive systems, easier to control, install and maintain, using standard protocols with low-power consumption. This work develops and test a low-cost sensor/actuator network platform, based in Internet of Things, integrating machine-to-machine and human-machine-interface protocols. Edge computing uses this multi-protocol approach to develop control processes on Precision Agriculture scenarios. A greenhouse with hydroponic crop production was developed and tested using Ubiquitous Sensor Network monitoring and edge control on Internet of Things paradigm. The experimental results showed that the Internet technologies and Smart Object Communication Patterns can be combined to encourage development of Precision Agriculture. They demonstrated added benefits (cost, energy, smart developing, acceptance by agricultural specialists) when a project is launched. PMID:27455265

  9. Assessment of Diverse Biological Indicators in Gulf War Illness: Are They Replicable Are They Related

    DTIC Science & Technology

    2016-04-01

    compared to 50 healthy veteran controls in a protocol that includes physical and neuropsychological evaluations, neuroimaging (MRI, fMRI, DTI), adrenal...SUBJECT TERMS Gulf War illness, neuroimaging, neuropsychological testing, immune function, hypothalamic-pituitary-adrenal testing 16. SECURITY... neuropsychological evaluations, assessment of hypothalamic-pituitary-adrenal function, standard clinical diagnostic laboratory tests, and research

  10. 40 CFR 266.103 - Interim status standards for burners.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... complying with the CO controls of § 266.104(c), the CO limit is established based on the compliance test... testing planned, including a complete copy of the test protocol and Quality Assurance/Quality Control (QA...; (vi) In subpart G (Closure and post-closure), §§ 265.111-265.115; (vii) In subpart H (Financial...

  11. 40 CFR 266.103 - Interim status standards for burners.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... complying with the CO controls of § 266.104(c), the CO limit is established based on the compliance test... testing planned, including a complete copy of the test protocol and Quality Assurance/Quality Control (QA...; (vi) In subpart G (Closure and post-closure), §§ 265.111-265.115; (vii) In subpart H (Financial...

  12. 40 CFR 266.103 - Interim status standards for burners.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... complying with the CO controls of § 266.104(c), the CO limit is established based on the compliance test... testing planned, including a complete copy of the test protocol and Quality Assurance/Quality Control (QA...; (vi) In subpart G (Closure and post-closure), §§ 265.111-265.115; (vii) In subpart H (Financial...

  13. 40 CFR 266.103 - Interim status standards for burners.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... complying with the CO controls of § 266.104(c), the CO limit is established based on the compliance test... testing planned, including a complete copy of the test protocol and Quality Assurance/Quality Control (QA...; (vi) In subpart G (Closure and post-closure), §§ 265.111-265.115; (vii) In subpart H (Financial...

  14. 40 CFR 266.103 - Interim status standards for burners.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... complying with the CO controls of § 266.104(c), the CO limit is established based on the compliance test... testing planned, including a complete copy of the test protocol and Quality Assurance/Quality Control (QA...; (vi) In subpart G (Closure and post-closure), §§ 265.111-265.115; (vii) In subpart H (Financial...

  15. Evaluation of refractive correction for standard automated perimetry in eyes wearing multifocal contact lenses

    PubMed Central

    Hirasawa, Kazunori; Ito, Hikaru; Ohori, Yukari; Takano, Yui; Shoji, Nobuyuki

    2017-01-01

    AIM To evaluate the refractive correction for standard automated perimetry (SAP) in eyes with refractive multifocal contact lenses (CL) in healthy young participants. METHODS Twenty-nine eyes of 29 participants were included. Accommodation was paralyzed in all participants with 1% cyclopentolate hydrochloride. SAP was performed using the Humphrey SITA-standard 24-2 and 10-2 protocol under three refractive conditions: monofocal CL corrected for near distance (baseline); multifocal CL corrected for distance (mCL-D); and mCL-D corrected for near vision using a spectacle lens (mCL-N). Primary outcome measures were the foveal threshold, mean deviation (MD), and pattern standard deviation (PSD). RESULTS The foveal threshold of mCL-N with both the 24-2 and 10-2 protocols significantly decreased by 2.2-2.5 dB (P<0.001), while that of mCL-D with the 24-2 protocol significantly decreased by 1.5 dB (P=0.0427), as compared with that of baseline. Although there was no significant difference between the MD of baseline and mCL-D with the 24-2 and 10-2 protocols, the MD of mCL-N was significantly decreased by 1.0-1.3 dB (P<0.001) as compared with that of both baseline and mCL-D, with both 24-2 and 10-2 protocols. There was no significant difference in the PSD among the three refractive conditions with both the 24-2 and 10-2 protocols. CONCLUSION Despite the induced mydriasis and the optical design of the multifocal lens used in this study, our results indicated that, when the dome-shaped visual field test is performed with eyes with large pupils and wearing refractive multifocal CLs, distance correction without additional near correction is to be recommended. PMID:29062776

  16. Evaluation of refractive correction for standard automated perimetry in eyes wearing multifocal contact lenses.

    PubMed

    Hirasawa, Kazunori; Ito, Hikaru; Ohori, Yukari; Takano, Yui; Shoji, Nobuyuki

    2017-01-01

    To evaluate the refractive correction for standard automated perimetry (SAP) in eyes with refractive multifocal contact lenses (CL) in healthy young participants. Twenty-nine eyes of 29 participants were included. Accommodation was paralyzed in all participants with 1% cyclopentolate hydrochloride. SAP was performed using the Humphrey SITA-standard 24-2 and 10-2 protocol under three refractive conditions: monofocal CL corrected for near distance (baseline); multifocal CL corrected for distance (mCL-D); and mCL-D corrected for near vision using a spectacle lens (mCL-N). Primary outcome measures were the foveal threshold, mean deviation (MD), and pattern standard deviation (PSD). The foveal threshold of mCL-N with both the 24-2 and 10-2 protocols significantly decreased by 2.2-2.5 dB ( P <0.001), while that of mCL-D with the 24-2 protocol significantly decreased by 1.5 dB ( P =0.0427), as compared with that of baseline. Although there was no significant difference between the MD of baseline and mCL-D with the 24-2 and 10-2 protocols, the MD of mCL-N was significantly decreased by 1.0-1.3 dB ( P <0.001) as compared with that of both baseline and mCL-D, with both 24-2 and 10-2 protocols. There was no significant difference in the PSD among the three refractive conditions with both the 24-2 and 10-2 protocols. Despite the induced mydriasis and the optical design of the multifocal lens used in this study, our results indicated that, when the dome-shaped visual field test is performed with eyes with large pupils and wearing refractive multifocal CLs, distance correction without additional near correction is to be recommended.

  17. Human immunodeficiency virus bDNA assay for pediatric cases.

    PubMed

    Avila, M M; Liberatore, D; Martínez Peralta, L; Biglione, M; Libonatti, O; Coll Cárdenas, P; Hodara, V L

    2000-01-01

    Techniques to quantify plasma HIV-1 RNA viral load (VL) are commercially available, and they are adequate for monitoring adults infected by HIV and treated with antiretroviral drugs. Little experience on HIV VL has been reported in pediatric cases. In Argentina, the evaluation of several assays for VL in pediatrics are now being considered. To evaluate the pediatric protocol for bDNA assay in HIV-infected children, 25 samples from HIV-infected children (according to CDC criteria for pediatric AIDS) were analyzed by using Quantiplex HIV RNA 2.0 Assay (Chiron Corporation) following the manufacturer's recommendations in a protocol that uses 50 microliters of patient's plasma (sensitivity: 10,000 copies/ml). When HIV-RNA was not detected, samples were run with the 1 ml standard bDNA protocol (sensitivity: 500 HIV-RNA c/ml). Nine samples belonged to infants under 12 months of age (group A) and 16 were over 12 months (group B). All infants under one year of age had high HIV-RNA copies in plasma. VL ranged from 30,800 to 2,560,000 RNA copies/ml (median = 362,000 c/ml) for group A and < 10,000 to 554,600 c/ml (median = < 10,000) for group B. Only 25% of children in group B had detectable HIV-RNA. By using the standard test of quantification, none of the patients had non detectable HIV-RNA, ranging between 950 and 226,200 c/ml for group B (median = 23,300 RNA c/ml). The suggested pediatric protocol could be useful in children under 12 months of age, but 1 ml standard protocol must be used for older children. Samples with undetectable results from children under one year of age should be repeated using the standard protocol.

  18. Development of a standardized protein immunomarking protocol for insect mark-capture dispersal research

    USDA-ARS?s Scientific Manuscript database

    A field study was conducted to test the marking efficiency of broadcast spray applications of protein marks on stationary (represented by cadavers) and free-roaming lady beetles, Hippodamia convergens Guérin-Méneville that were strategically placed in blooming alfalfa plots. The marks tested include...

  19. Quantitative Sensory Testing in Adults with Autism Spectrum Disorders

    ERIC Educational Resources Information Center

    Fründt, Odette; Grashorn, Wiebke; Schöttle, Daniel; Peiker, Ina; David, Nicole; Engel, Andreas K.; Forkmann, Katarina; Wrobel, Nathalie; Münchau, Alexander; Bingel, Ulrike

    2017-01-01

    Altered sensory perception has been found in patients with autism spectrum disorders (ASD) and might be related to aberrant sensory perception thresholds. We used the well-established, standardized Quantitative sensory testing (QST) protocol of the German Research Network on Neuropathic Pain to investigate 13 somatosensory parameters including…

  20. Use of IPsec by Manned Space Missions

    NASA Technical Reports Server (NTRS)

    Pajevski, Michael J.

    2009-01-01

    NASA's Constellation Program is developing its next generation manned space systems for missions to the International Space Station (ISS) and the Moon. The Program is embarking on a path towards standards based Internet Protocol (IP) networking for space systems communication. The IP based communications will be paired with industry standard security mechanisms such as Internet Protocol Security (IPsec) to ensure the integrity of information exchanges and prevent unauthorized release of sensitive information in-transit. IPsec has been tested in simulations on the ground and on at least one Earth orbiting satellite, but the technology is still unproven in manned space mission situations and significant obstacles remain.

  1. Integrated Circuit Chip Improves Network Efficiency

    NASA Technical Reports Server (NTRS)

    2008-01-01

    Prior to 1999 and the development of SpaceWire, a standard for high-speed links for computer networks managed by the European Space Agency (ESA), there was no high-speed communications protocol for flight electronics. Onboard computers, processing units, and other electronics had to be designed for individual projects and then redesigned for subsequent projects, which increased development periods, costs, and risks. After adopting the SpaceWire protocol in 2000, NASA implemented the standard on the Swift mission, a gamma ray burst-alert telescope launched in November 2004. Scientists and developers on the James Webb Space Telescope further developed the network version of SpaceWire. In essence, SpaceWire enables more science missions at a lower cost, because it provides a standard interface between flight electronics components; new systems need not be custom built to accommodate individual missions, so electronics can be reused. New protocols are helping to standardize higher layers of computer communication. Goddard Space Flight Center improved on the ESA-developed SpaceWire by enabling standard protocols, which included defining quality of service and supporting plug-and-play capabilities. Goddard upgraded SpaceWire to make the routers more efficient and reliable, with features including redundant cables, simultaneous discrete broadcast pulses, prevention of network blockage, and improved verification. Redundant cables simplify management because the user does not need to worry about which connection is available, and simultaneous broadcast signals allow multiple users to broadcast low-latency side-band signal pulses across the network using the same resources for data communication. Additional features have been added to the SpaceWire switch to prevent network blockage so that more robust networks can be designed. Goddard s verification environment for the link-and-switch implementation continuously randomizes and tests different parts, constantly anticipating situations, which helps improve communications reliability. It has been tested in many different implementations for compatibility.

  2. Optimizing otoacoustic emission protocols for a UNHS program.

    PubMed

    Hatzopoulos, S; Petruccelli, J; Ciorba, A; Martini, A

    2009-01-01

    To identify the optimal test protocol to screen for hearing problems in newborns, an evaluation of three distortion product otoacoustic emission (DPOAE) protocols was conducted in neonates, from a well-baby nursery (WBN) and from a neonatal intensive care unit (NICU) and compared to the performance in newborns of a more standard protocol based on transient-evoked OAEs (TEOAEs). The DPOAE protocols used asymmetrical stimulus intensities (L(1) > L(2)) with a frequency ratio of 1.22, in the following format: (P1), L(1) = 60, L(2) = 50 dB SPL; (P2), L(1) = 65, L(2) = 55 dB SPL, and (P3), L(1) = 75, L(2) = 65 dB SPL. Linear TEOAE responses, evoked by click stimuli of 75 dB peSPL, were used as controls of normal cochlear function. Five frequencies at 1.5, 2.0, 3.0, 4.0 and 5.0 kHz were tested with a common commercially available macro-based software subroutine (Otodynamics Corp, ILO-92). The project evaluated the responses from 1200 WBN infants (average age 48 h) and 350 low-birth-weight NICU infants, all randomly selected. Statistical analyses comparing the signal-to-noise ratios (S/N), at the predefined f(2) frequencies, indicated that the P1 and P2 DPOAE protocols generated similar responses. Significant S/N differences were observed in the P3 to P2 dataset comparisons. DPOAE scoring criteria were estimated from the P3 dataset using a one-sided, distribution-free confidence intervals. The scoring criteria for a 'pass' were estimated as a minimum S/N of 6.0, 7.0 and 6.0 dB at 2.0, 3.0 and 4.0 kHz, respectively. In terms of feasibility, the P3 protocol generated responses in 98% of the WBN and 94.8% of the NICU infants. All three DPOAE protocols demonstrated shorter time-recording requirements than the standard TEOAE test. The false-positive and false-negative rates for the NICU infants were estimated as 0.0028 and 0.003%, respectively.

  3. Supervised versus unsupervised technology-based levodopa monitoring in Parkinson's disease: an intrasubject comparison.

    PubMed

    Lopane, Giovanna; Mellone, Sabato; Corzani, Mattia; Chiari, Lorenzo; Cortelli, Pietro; Calandra-Buonaura, Giovanna; Contin, Manuela

    2018-06-01

    We aimed to assess the intrasubject reproducibility of a technology-based levodopa (LD) therapeutic monitoring protocol administered in supervised versus unsupervised conditions in patients with Parkinson's disease (PD). The study design was pilot, intrasubject, single center, open and prospective. Twenty patients were recruited. Patients performed a standardized monitoring protocol instrumented by an ad hoc embedded platform after their usual first morning LD dose in two different randomized ambulatory sessions: one under a physician's supervision, the other self-administered. The protocol is made up of serial motor and non-motor tests, including alternate finger tapping, Timed Up and Go test, and measurement of blood pressure. Primary motor outcomes included comparisons of intrasubject LD subacute motor response patterns over the 3-h test in the two experimental conditions. Secondary outcomes were the number of intrasession serial test repetitions due to technical or handling errors and patients' satisfaction with the unsupervised LD monitoring protocol. Intrasubject LD motor response patterns were concordant between the two study sessions in all patients but one. Platform handling problems averaged 4% of total planned serial tests for both sessions. Ninety-five percent of patients were satisfied with the self-administered LD monitoring protocol. To our knowledge, this study is the first to explore the potential of unsupervised technology-based objective motor and non-motor tasks to monitor subacute LD dosing effects in PD patients. The results are promising for future telemedicine applications.

  4. Development and Operation of Dual-Mode Analyzers for Wireless Power Consortium/Power Matters Alliance Wireless Power Systems.

    PubMed

    Um, Keehong

    2016-05-01

    We have designed a protocol analyzer to be used in wireless power systems and analyzed the operation of wireless chargers defined by standards of Qi of Wireless Power Consortium (WPC) and Power Matters Alliance (PMA) protocols. The integrated circuit (IC, or microchip) developed so far for wireless power transmission is not easily adopted by chargers for specific purposes. A device for measuring the performance of test equipment currently available is required to transform and expand the types of protocol. Since a protocol analyzer with these functions is required, we have developed a device that can analyze the two protocols of WPC and PMA at the same time. As a result of our research, we present a dual-mode system that can analyze the protocols of both WPC and PMA.

  5. Comparing rapid methods for detecting Listeria in seafood and environmental samples using the most probably number (MPN) technique.

    PubMed

    Cruz, Cristina D; Win, Jessicah K; Chantarachoti, Jiraporn; Mutukumira, Anthony N; Fletcher, Graham C

    2012-02-15

    The standard Bacteriological Analytical Manual (BAM) protocol for detecting Listeria in food and on environmental surfaces takes about 96 h. Some studies indicate that rapid methods, which produce results within 48 h, may be as sensitive and accurate as the culture protocol. As they only give presence/absence results, it can be difficult to compare the accuracy of results generated. We used the Most Probable Number (MPN) technique to evaluate the performance and detection limits of six rapid kits for detecting Listeria in seafood and on an environmental surface compared with the standard protocol. Three seafood products and an environmental surface were inoculated with similar known cell concentrations of Listeria and analyzed according to the manufacturers' instructions. The MPN was estimated using the MPN-BAM spreadsheet. For the seafood products no differences were observed among the rapid kits and efficiency was similar to the BAM method. On the environmental surface the BAM protocol had a higher recovery rate (sensitivity) than any of the rapid kits tested. Clearview™, Reveal®, TECRA® and VIDAS® LDUO detected the cells but only at high concentrations (>10(2) CFU/10 cm(2)). Two kits (VIP™ and Petrifilm™) failed to detect 10(4) CFU/10 cm(2). The MPN method was a useful tool for comparing the results generated by these presence/absence test kits. There remains a need to develop a rapid and sensitive method for detecting Listeria in environmental samples that performs as well as the BAM protocol, since none of the rapid tests used in this study achieved a satisfactory result. Copyright © 2011 Elsevier B.V. All rights reserved.

  6. VO2max Testing in Trail Runners: Is There a Specific Exercise Test Protocol?

    PubMed

    Scheer, Volker; Ramme, Katharina; Reinsberger, Claus; Heitkamp, Hans-Christian

    2018-06-01

    Trail running places specific physiological demands on the human body due to its uphill and downhill running sections. We developed and investigated a more sport-specific trail exercise test protocol (inclination and speed incremental protocol), and compared it to two standard exercise test protocols (horizontal step and ramp protocol) in thirteen highly trained trail runners (age 31±6 years, height 179±6.4 cm, weight 69.2±7.9 kg, BMI 21.6±2.1 kg/m 2 ). The maximum oxygen uptake (VO 2 max) measured during the trail test (62.5±5.9 ml·kg -1 ·min -1 , [95% CI: 59.0-66.1]) was significantly higher compared to both the step test (60.1±5.3 ml·kg -1 ·min -1 , [95% CI: 56.8-63.3], p=0.024) and the ramp test (59.7±5.5 ml·kg -1 ·min -1 , [95% CI: 56.4-63.0], p=0.028). Time to task failure was significantly shorter in the trail test (557±73 s, [95% CI: 512-601]) compared to both the step test (1378±152 s, [95% CI: 1286-1470], p<0.001) and the ramp test (605±95, [95% CI: 547-662], p<0.001). Other physiological measurements obtained were similar. The trail test was the preferred choice in our group of trail runners. This study supports the implementation of the trail test in practice, and recommends that its validity be evaluated further. © Georg Thieme Verlag KG Stuttgart · New York.

  7. Do we need 3D tube current modulation information for accurate organ dosimetry in chest CT? Protocols dose comparisons.

    PubMed

    Lopez-Rendon, Xochitl; Zhang, Guozhi; Coudyzer, Walter; Develter, Wim; Bosmans, Hilde; Zanca, Federica

    2017-11-01

    To compare the lung and breast dose associated with three chest protocols: standard, organ-based tube current modulation (OBTCM) and fast-speed scanning; and to estimate the error associated with organ dose when modelling the longitudinal (z-) TCM versus the 3D-TCM in Monte Carlo simulations (MC) for these three protocols. Five adult and three paediatric cadavers with different BMI were scanned. The CTDI vol of the OBTCM and the fast-speed protocols were matched to the patient-specific CTDI vol of the standard protocol. Lung and breast doses were estimated using MC with both z- and 3D-TCM simulated and compared between protocols. The fast-speed scanning protocol delivered the highest doses. A slight reduction for breast dose (up to 5.1%) was observed for two of the three female cadavers with the OBTCM in comparison to the standard. For both adult and paediatric, the implementation of the z-TCM data only for organ dose estimation resulted in 10.0% accuracy for the standard and fast-speed protocols, while relative dose differences were up to 15.3% for the OBTCM protocol. At identical CTDI vol values, the standard protocol delivered the lowest overall doses. Only for the OBTCM protocol is the 3D-TCM needed if an accurate (<10.0%) organ dosimetry is desired. • The z-TCM information is sufficient for accurate dosimetry for standard protocols. • The z-TCM information is sufficient for accurate dosimetry for fast-speed scanning protocols. • For organ-based TCM schemes, the 3D-TCM information is necessary for accurate dosimetry. • At identical CTDI vol , the fast-speed scanning protocol delivered the highest doses. • Lung dose was higher in XCare than standard protocol at identical CTDI vol .

  8. Normalization of cortical thickness measurements across different T1 magnetic resonance imaging protocols by novel W-Score standardization.

    PubMed

    Chung, Jinyong; Yoo, Kwangsun; Lee, Peter; Kim, Chan Mi; Roh, Jee Hoon; Park, Ji Eun; Kim, Sang Joon; Seo, Sang Won; Shin, Jeong-Hyeon; Seong, Joon-Kyung; Jeong, Yong

    2017-10-01

    The use of different 3D T1-weighted magnetic resonance (T1 MR) imaging protocols induces image incompatibility across multicenter studies, negating the many advantages of multicenter studies. A few methods have been developed to address this problem, but significant image incompatibility still remains. Thus, we developed a novel and convenient method to improve image compatibility. W-score standardization creates quality reference values by using a healthy group to obtain normalized disease values. We developed a protocol-specific w-score standardization to control the protocol effect, which is applied to each protocol separately. We used three data sets. In dataset 1, brain T1 MR images of normal controls (NC) and patients with Alzheimer's disease (AD) from two centers, acquired with different T1 MR protocols, were used (Protocol 1 and 2, n = 45/group). In dataset 2, data from six subjects, who underwent MRI with two different protocols (Protocol 1 and 2), were used with different repetition times, echo times, and slice thicknesses. In dataset 3, T1 MR images from a large number of healthy normal controls (Protocol 1: n = 148, Protocol 2: n = 343) were collected for w-score standardization. The protocol effect and disease effect on subjects' cortical thickness were analyzed before and after the application of protocol-specific w-score standardization. As expected, different protocols resulted in differing cortical thickness measurements in both NC and AD subjects. Different measurements were obtained for the same subject when imaged with different protocols. Multivariate pattern difference between measurements was observed between the protocols. Classification accuracy between two protocols was nearly 90%. After applying protocol-specific w-score standardization, the differences between the protocols substantially decreased. Most importantly, protocol-specific w-score standardization reduced both univariate and multivariate differences in the images while maintaining the AD disease effect. Compared to conventional regression methods, our method showed the best performance for in terms of controlling the protocol effect while preserving disease information. Protocol-specific w-score standardization effectively resolved the concerns of conventional regression methods. It showed the best performance for improving the compatibility of a T1 MR post-processed feature, cortical thickness. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Evaluation of a High Throughput Starch Analysis Optimised for Wood

    PubMed Central

    Bellasio, Chandra; Fini, Alessio; Ferrini, Francesco

    2014-01-01

    Starch is the most important long-term reserve in trees, and the analysis of starch is therefore useful source of physiological information. Currently published protocols for wood starch analysis impose several limitations, such as long procedures and a neutralization step. The high-throughput standard protocols for starch analysis in food and feed represent a valuable alternative. However, they have not been optimised or tested with woody samples. These have particular chemical and structural characteristics, including the presence of interfering secondary metabolites, low reactivity of starch, and low starch content. In this study, a standard method for starch analysis used for food and feed (AOAC standard method 996.11) was optimised to improve precision and accuracy for the analysis of starch in wood. Key modifications were introduced in the digestion conditions and in the glucose assay. The optimised protocol was then evaluated through 430 starch analyses of standards at known starch content, matrix polysaccharides, and wood collected from three organs (roots, twigs, mature wood) of four species (coniferous and flowering plants). The optimised protocol proved to be remarkably precise and accurate (3%), suitable for a high throughput routine analysis (35 samples a day) of specimens with a starch content between 40 mg and 21 µg. Samples may include lignified organs of coniferous and flowering plants and non-lignified organs, such as leaves, fruits and rhizomes. PMID:24523863

  10. Disentangling the nature of the nicotine stimulus.

    PubMed

    Bevins, Rick A; Barrett, Scott T; Polewan, Robert J; Pittenger, Steven T; Swalve, Natashia; Charntikov, Sergios

    2012-05-01

    Learning involving interoceptive stimuli likely plays an important role in many diseases and psychopathologies. Within this area, there has been extensive research investigating the interoceptive stimulus effects of abused drugs. In this pursuit, behavioral pharmacologists have taken advantage of what is known about learning processes and adapted the techniques to investigate the behavioral and receptor mechanisms of drug stimuli. Of particular interest is the nicotine stimulus and the use of the two-lever operant drug discrimination task and the Pavlovian drug discriminated goal-tracking task. There is strong concordance between the two methods when using "standard" testing protocols that minimize learning on test days. For example, ABT-418, nornicotine, and varenicline all fully evoked nicotine-appropriate responding. Notably, research from our laboratory with the discriminated goal-tracking task has used an alternative testing protocol. This protocol assesses stimulus substitution based on how well extinction learning using a non-nicotine ligand transfers back to the nicotine stimulus. These findings challenge conclusions based on more "standard" testing procedures (e.g., ABT-418 is not nicotine-like). As a starting point, we propose Thurstone scaling as a quantitative method for more precisely comparing transfer of extinction across doses, experiments, and investigators. We close with a discussion of future research directions and potential implications of the research for understanding interoceptive stimuli. Copyright © 2011 Elsevier B.V. All rights reserved.

  11. Diagnostic accuracy of refractometer and Brix refractometer to assess failure of passive transfer in calves: protocol for a systematic review and meta-analysis.

    PubMed

    Buczinski, S; Fecteau, G; Chigerwe, M; Vandeweerd, J M

    2016-06-01

    Calves are highly dependent of colostrum (and antibody) intake because they are born agammaglobulinemic. The transfer of passive immunity in calves can be assessed directly by dosing immunoglobulin G (IgG) or by refractometry or Brix refractometry. The latter are easier to perform routinely in the field. This paper presents a protocol for a systematic review meta-analysis to assess the diagnostic accuracy of refractometry or Brix refractometry versus dosage of IgG as a reference standard test. With this review protocol we aim to be able to report refractometer and Brix refractometer accuracy in terms of sensitivity and specificity as well as to quantify the impact of any study characteristic on test accuracy.

  12. Air toxics evaluation of ABB Combustion Engineering Low-Emission Boiler Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wesnor, J.D.

    1993-10-26

    The specific goals of the program are to identify air toxic compounds that might be emmitted from the new boiler with its various Air Pollution Control device for APCD alternatives in levels of regulatory concern. For the compounds thought to be of concern, potential air toxic control methodologies will be suggested and a Test Protocol will be written to be used in the Proof of Concept and full scale tests. The following task was defined: Define Replations and Standards; Identify Air Toxic Pollutants of Interest to Interest to Utility Boilers; Assesment of Air Toxic By-Products; State of the Art Assessmentmore » of Toxic By-Product Control Technologies; and Test Protocol Definition.« less

  13. A novel protocol for dispatcher assisted CPR improves CPR quality and motivation among rescuers-A randomized controlled simulation study.

    PubMed

    Rasmussen, Stinne Eika; Nebsbjerg, Mette Amalie; Krogh, Lise Qvirin; Bjørnshave, Katrine; Krogh, Kristian; Povlsen, Jonas Agerlund; Riddervold, Ingunn Skogstad; Grøfte, Thorbjørn; Kirkegaard, Hans; Løfgren, Bo

    2017-01-01

    Emergency dispatchers use protocols to instruct bystanders in cardiopulmonary resuscitation (CPR). Studies changing one element in the dispatcher's protocol report improved CPR quality. Whether several changes interact is unknown and the effect of combining multiple changes previously reported to improve CPR quality into one protocol remains to be investigated. We hypothesize that a novel dispatch protocol, combining multiple beneficial elements improves CPR quality compared with a standard protocol. A novel dispatch protocol was designed including wording on chest compressions, using a metronome, regular encouragements and a 10-s rest each minute. In a simulated cardiac arrest scenario, laypersons were randomized to perform single-rescuer CPR guided with the novel or the standard protocol. a composite endpoint of time to first compression, hand position, compression depth and rate and hands-off time (maximum score: 22 points). Afterwards participants answered a questionnaire evaluating the dispatcher assistance. The novel protocol (n=61) improved CPR quality score compared with the standard protocol (n=64) (mean (SD): 18.6 (1.4)) points vs. 17.5 (1.7) points, p<0.001. The novel protocol resulted in deeper chest compressions (mean (SD): 58 (12)mm vs. 52 (13)mm, p=0.02) and improved rate of correct hand position (61% vs. 36%, p=0.01) compared with the standard protocol. In both protocols hands-off time was short. The novel protocol improved motivation among rescuers compared with the standard protocol (p=0.002). Participants guided with a standard dispatch protocol performed high quality CPR. A novel bundle of care protocol improved CPR quality score and motivation among rescuers. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  14. Influence of basis images and skull position on evaluation of cortical bone thickness in cone beam computed tomography.

    PubMed

    Nascimento, Monikelly do Carmo Chagas; Boscolo, Solange Maria de Almeida; Haiter-Neto, Francisco; Santos, Emanuela Carla Dos; Lambrichts, Ivo; Pauwels, Ruben; Jacobs, Reinhilde

    2017-06-01

    The aim of this study was to assess the influence of the number of basis images and the orientation of the skull on the evaluation of cortical alveolar bone in cone beam computed tomography (CBCT). Eleven skulls with a total of 59 anterior teeth were selected. CBCT images were acquired by using 4 protocols, by varying the rotation of the tube-detector arm and the orientation of the skull (protocol 1: 360°/0°; protocol 2: 180°/0°; protocol 3: 180°/90°; protocol 4: 180°/180°). Observers evaluated cortical bone as absent, thin, or thick. Direct observation of the skulls was used as the gold standard. Intra- and interobserver agreement, as well as agreement of scoring between the 3 bone thickness classifications, were calculated by using the κ statistic. The Wilcoxon signed-rank test was used to compare the 4 protocols. For lingual cortical bone, protocol 1 showed no statistical difference from the gold standard. Higher reliability was found in protocol 3 for absent (κ = 0.80) and thin (κ = 0.47) cortices, whereas for thick cortical bone, protocol 2 was more consistent (κ = 0.60). In buccal cortical bone, protocol 1 obtained the highest agreement for absent cortices (κ = 0.61), whereas protocol 4 was better for thin cortical plates (κ = 0.38) and protocol 2 for thick cortical plates (κ = 0.40). No consistent effect of the number of basis images or head orientation for visual detection of alveolar bone was detected, except for lingual cortical bone, for which full rotation scanning showed improved visualization. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Do we really need in-situ bioassays?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Salazar, M.H.; Salazar, S.M.

    1995-12-31

    In-situ bioassays are needed to validate the results from laboratory testing and to understand biological interactions. Standard laboratory protocols provide reproducible test results, and the precision of those tests can be mathematically defined. Significant correlations between toxic substances and levels of response (bioaccumulation and bioeffects) have also been demonstrated with natural field populations and suggest that the laboratory results can accurately predict field responses. An equal number of studies have shown a lack of correlation between laboratory bioassay results and responses of natural field populations. The best way to validate laboratory results is with manipulative field testing; i.e., in-situ bioassaysmore » with caged organisms. Bioaccumulation in transplanted bivalves has probably been the most frequently used form of an in-situ bioassay. The authors have refined those methods to include synoptic measurements of bioaccumulation and growth. Growth provides an easily-measured bioeffects endpoint and a means of calibrating bioaccumulation. Emphasis has been on minimizing the size range of test animals, repetitive measurements of individuals and standardization of test protocols for a variety of applications. They are now attempting to standardize criteria for accepting and interpreting data in the same way that laboratory bioassays have been standardized. Others have developed methods for in-situ bioassays using eggs, larvae, unicellular organisms, crustaceans, benthic invertebrates, bivalves, and fish. In the final analysis, the in-situ approach could be considered as an exposure system where any clinical measurements are possible. The most powerful approach would be to use the same species in laboratory and field experiments with the same endpoints.« less

  16. A Multi-Year Plan for Research, Development, and Prototype Testing of Standard Modular Hydropower Technology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, Brennan T.; Welch, Tim; Witt, Adam M.

    The Multi-Year Plan for Research, Development, and Prototype Testing of Standard Modular Hydropower Technology (MYRP) presents a strategy for specifying, designing, testing, and demonstrating the efficacy of standard modular hydropower (SMH) as an environmentally compatible and cost-optimized renewable electricity generation technology. The MYRP provides the context, background, and vision for testing the SMH hypothesis: if standardization, modularity, and preservation of stream functionality become essential and fully realized features of hydropower technology, project design, and regulatory processes, they will enable previously unrealized levels of new project development with increased acceptance, reduced costs, increased predictability of outcomes, and increased value to stakeholders.more » To achieve success in this effort, the MYRP outlines a framework of stakeholder-validated criteria, models, design tools, testing facilities, and assessment protocols that will facilitate the development of next-generation hydropower technologies.« less

  17. The predictive value of skin prick testing for challenge-proven food allergy: a systematic review.

    PubMed

    Peters, Rachel L; Gurrin, Lyle C; Allen, Katrina J

    2012-06-01

    Immunoglobulin E-mediated (IgE) food allergy affects 6-8% of children, and the prevalence is believed to be increasing. The gold standard of food allergy diagnosis is oral food challenges (OFCs); however, they are resource-consuming and potentially dangerous. Skin prick tests (SPTs) are able to detect the presence of allergen-specific IgE antibodies (sensitization), but they have low specificity for clinically significant food allergy. To reduce the need for OFCs, it has been suggested that children forgo an OFC if their SPT wheal size exceeds a cutoff that has a high predictability for food allergy. Although data for these studies are almost always gathered from high-risk populations, the 95% positive predictive values (PPVs) vary substantially between studies. SPT thresholds with a high probability of food allergy generated from these studies may not be generalizable to other populations, because of highly selective samples and variability in participant's age, test allergens, and food challenge protocol. Standardization of SPT devices and allergens, OFC protocols including standardized cessation criteria, and population-based samples would all help to improve generalizability of PPVs of SPTs. © 2011 John Wiley & Sons A/S.

  18. Comparing technical proficiency of elite table tennis players with intellectual disability: simulation testing versus game play.

    PubMed

    Van Biesen, Debbie; Mactavish, Jennifer J; Vanlandewijck, Yves C

    2014-04-01

    Technical skill proficiency among elite table tennis players with intellectual disabilities (ID) was investigated in this study using two approaches: an off-court simulation testing protocol and an on-court, standardized observational framework during game play. Participants included 24 players with ID (M age = 25 yr., SD = 6; M IQ = 61, SD = 9), the top 16 performers, 13 men and 11 women, at the International Federation for sport for para-athletes with an intellectual disability (Inas) World Championships. Self-reported table tennis training experience of the players was 13 +/- 5 yr. In the Simulation Testing condition, players were instructed to play five sets of basic and five sets of advanced skills, which were subsequently assessed by experts using a standardized and validated observational protocol. The same protocol was used to assess the same skills during Game Play. Ratings of overall technical proficiency were not significantly different between Simulation Testing and Game Play conditions. There was a strong positive correlation between technical proficiency measured during Game Play vs Simulation Testing for the variables flick, topspin forehand, and topspin backhand. No correlations were found for the variables contra, block, and push. Insight into this relationship is important for future development of classification systems for ID athletes in the Paralympic Games, because comparing competition observation with the athlete's potential shown during the classification session is essential information for classifiers to confirm the athlete's competition class.

  19. Effects of dynamic head tilts on sensory organization test performance: a comparison between college-age athletes and nonathletes.

    PubMed

    Clark, Sean; Iltis, Peter W

    2008-05-01

    Controlled laboratory study. To compare postural performance measures of athletes with those of nonathletes when completing the standard Sensory Organization Test (SOT) and a modified SOT that included dynamic head tilts (DHT-SOT). Authors of recently published research have suggested that modifications to the SOT protocol (eg, introduction of pitch and roll head tilts) may enhance the test's sensitivity when assessing postural stability in individuals with higher balance capabilities or with well-compensated sensory deficits. Nineteen athletes and 19 nonathletes (group) completed both the SOT and DHT-SOT (protocol). During the SOT, participants stood upright as steadily as possible for 20 seconds during each of 6 different sensory conditions. As a variation of the SOT, the DHT-SOT incorporated active pitch and roll head tilts into the SOT protocol. Four 2-way mixed-model analyses of variance (with protocol as the repeated factor) were performed to determine if the composite equilibrium score or the visual, vestibular, or somatosensory ratio scores differed between the 2 groups across the 2 testing protocols. Significant group-by-protocol interaction effects were present for both the composite equilibrium score and visual ratio. Follow-up simple main-effects analyses indicated that these measures did not differ between groups for the SOT protocol but were significantly different on the DHT-SOT. The addition of dynamic head tilts to the SOT protocol resulted in subtle differences in balance function between athletes and nonathletes. Athletes demonstrated an increased ability to adapt to sensory disruptions during the DHT-SOT. Therapists should consider including active pitch and roll head tilts to the SOT when evaluating individuals with higher balance function or to detect subtle deficits in balance function. Diagnosis, level 3b.

  20. Evaluation of Aspergillus PCR protocols for testing serum specimens.

    PubMed

    White, P Lewis; Mengoli, Carlo; Bretagne, Stéphane; Cuenca-Estrella, Manuel; Finnstrom, Niklas; Klingspor, Lena; Melchers, Willem J G; McCulloch, Elaine; Barnes, Rosemary A; Donnelly, J Peter; Loeffler, Juergen

    2011-11-01

    A panel of human serum samples spiked with various amounts of Aspergillus fumigatus genomic DNA was distributed to 23 centers within the European Aspergillus PCR Initiative to determine analytical performance of PCR. Information regarding specific methodological components and PCR performance was requested. The information provided was made anonymous, and meta-regression analysis was performed to determine any procedural factors that significantly altered PCR performance. Ninety-seven percent of protocols were able to detect a threshold of 10 genomes/ml on at least one occasion, with 83% of protocols reproducibly detecting this concentration. Sensitivity and specificity were 86.1% and 93.6%, respectively. Positive associations between sensitivity and the use of larger sample volumes, an internal control PCR, and PCR targeting the internal transcribed spacer (ITS) region were shown. Negative associations between sensitivity and the use of larger elution volumes (≥100 μl) and PCR targeting the mitochondrial genes were demonstrated. Most Aspergillus PCR protocols used to test serum generate satisfactory analytical performance. Testing serum requires less standardization, and the specific recommendations shown in this article will only improve performance.

  1. Evaluation of Aspergillus PCR Protocols for Testing Serum Specimens▿†

    PubMed Central

    White, P. Lewis; Mengoli, Carlo; Bretagne, Stéphane; Cuenca-Estrella, Manuel; Finnstrom, Niklas; Klingspor, Lena; Melchers, Willem J. G.; McCulloch, Elaine; Barnes, Rosemary A.; Donnelly, J. Peter; Loeffler, Juergen

    2011-01-01

    A panel of human serum samples spiked with various amounts of Aspergillus fumigatus genomic DNA was distributed to 23 centers within the European Aspergillus PCR Initiative to determine analytical performance of PCR. Information regarding specific methodological components and PCR performance was requested. The information provided was made anonymous, and meta-regression analysis was performed to determine any procedural factors that significantly altered PCR performance. Ninety-seven percent of protocols were able to detect a threshold of 10 genomes/ml on at least one occasion, with 83% of protocols reproducibly detecting this concentration. Sensitivity and specificity were 86.1% and 93.6%, respectively. Positive associations between sensitivity and the use of larger sample volumes, an internal control PCR, and PCR targeting the internal transcribed spacer (ITS) region were shown. Negative associations between sensitivity and the use of larger elution volumes (≥100 μl) and PCR targeting the mitochondrial genes were demonstrated. Most Aspergillus PCR protocols used to test serum generate satisfactory analytical performance. Testing serum requires less standardization, and the specific recommendations shown in this article will only improve performance. PMID:21940479

  2. Robust Sub-nanomolar Library Preparation for High Throughput Next Generation Sequencing.

    PubMed

    Wu, Wells W; Phue, Je-Nie; Lee, Chun-Ting; Lin, Changyi; Xu, Lai; Wang, Rong; Zhang, Yaqin; Shen, Rong-Fong

    2018-05-04

    Current library preparation protocols for Illumina HiSeq and MiSeq DNA sequencers require ≥2 nM initial library for subsequent loading of denatured cDNA onto flow cells. Such amounts are not always attainable from samples having a relatively low DNA or RNA input; or those for which a limited number of PCR amplification cycles is preferred (less PCR bias and/or more even coverage). A well-tested sub-nanomolar library preparation protocol for Illumina sequencers has however not been reported. The aim of this study is to provide a much needed working protocol for sub-nanomolar libraries to achieve outcomes as informative as those obtained with the higher library input (≥ 2 nM) recommended by Illumina's protocols. Extensive studies were conducted to validate a robust sub-nanomolar (initial library of 100 pM) protocol using PhiX DNA (as a control), genomic DNA (Bordetella bronchiseptica and microbial mock community B for 16S rRNA gene sequencing), messenger RNA, microRNA, and other small noncoding RNA samples. The utility of our protocol was further explored for PhiX library concentrations as low as 25 pM, which generated only slightly fewer than 50% of the reads achieved under the standard Illumina protocol starting with > 2 nM. A sub-nanomolar library preparation protocol (100 pM) could generate next generation sequencing (NGS) results as robust as the standard Illumina protocol. Following the sub-nanomolar protocol, libraries with initial concentrations as low as 25 pM could also be sequenced to yield satisfactory and reproducible sequencing results.

  3. Standardization and validation of real time PCR assays for the diagnosis of histoplasmosis using three molecular targets in an animal model.

    PubMed

    López, Luisa F; Muñoz, César O; Cáceres, Diego H; Tobón, Ángela M; Loparev, Vladimir; Clay, Oliver; Chiller, Tom; Litvintseva, Anastasia; Gade, Lalitha; González, Ángel; Gómez, Beatriz L

    2017-01-01

    Histoplasmosis is considered one of the most important endemic and systemic mycoses worldwide. Until now few molecular techniques have been developed for its diagnosis. The aim of this study was to develop and evaluate three real time PCR (qPCR) protocols for different protein-coding genes (100-kDa, H and M antigens) using an animal model. Fresh and formalin-fixed and paraffin-embedded (FFPE) lung tissues from BALB/c mice inoculated i.n. with 2.5x106 Histoplasma capsulatum yeast or PBS were obtained at 1, 2, 3, 4, 8, 12 and 16 weeks post-infection. A collection of DNA from cultures representing different clades of H. capsulatum (30 strains) and other medically relevant pathogens (36 strains of related fungi and Mycobacterium tuberculosis) were used to analyze sensitivity and specificity. Analytical sensitivity and specificity were 100% when DNAs from the different strains were tested. The highest fungal burden occurred at first week post-infection and complete fungal clearance was observed after the third week; similar results were obtained when the presence of H. capsulatum yeast cells was demonstrated in histopathological analysis. In the first week post-infection, all fresh and FFPE lung tissues from H. capsulatum-infected animals were positive for the qPCR protocols tested except for the M antigen protocol, which gave variable results when fresh lung tissue samples were analyzed. In the second week, all qPCR protocols showed variable results for both fresh and FFPE tissues. Samples from the infected mice at the remaining times post-infection and uninfected mice (controls) were negative for all protocols. Good agreement was observed between CFUs, histopathological analysis and qPCR results for the 100-kDa and H antigen protocols. We successfully standardized and validated three qPCR assays for detecting H. capsulatum DNA in fresh and FFPE tissues, and conclude that the 100-kDa and H antigen molecular assays are promising tests for diagnosing this mycosis.

  4. 391 Description of Drug Allergy Study Conducted in a Teaching Hospital between October 2007 and March 2011

    PubMed Central

    Rodríguez Martínez, Consuelo Fernanda; Rubio, Alicia Sciaraffia

    2012-01-01

    Background The World Allergy Organization (WAO) in 2003 defined ‘drug allergy’ as an immunologically mediated drug hypersensitivity reaction. The mechanism of drug allergy may be either IgE or non-IgE mediated. The true incidence of drug allergy is not known. There are only few studies/datasets using standardized clinical questionnaires and validated in vivo or in vitro tests to confirm the diagnosis of drug allergy. Here we have analyzed the obtained results of in vivo test in suspected drug allergy patients. Methods Data from the Centre of Allergies of the Clinical Hospital of the Universidad de Chile between the months of October 2007 and March 2011 was obtained. The information of the protocols of drug executed, by defining as Protocol the study of a probable allergy by 2 or more procedures, which can be: Prick Test, intradermal reaction, specific IgE and/or Test Patch. Results For a total of 126 drug protocols, 25% of them were trivírica vaccine, 24% β-lactams, 21% local anaesthetics and 10% to general anesthesia (inductors, muscle relaxants and Latex). Of the total of patients undergoing protocols the most of them were women, there is no clear difference between the number of children and adults. The temporal distribution of protocols was stable between the months of October 2007 and March 2009 (15 protocols/semester), to then become variable, reaching values between 10 and 29 every 6 months. Of total protocols, 30.1% were positive; only one patient presented a mild adverse reaction (local welt). The β-lactams being most often the positive drugs. Protocols involving pethidine 100% was positive, diclofenac 33%, dipyrone, ketoprofen and hydrocortisone each one 25%. The most accomplished protocol was trivírica vaccine, resulting in 100% negative. Of all negative protocols 58% went to provocation, resulting in a 8% positive, including one provocation to the trívirica vaccine. Conclusions Methodologicall study is very important for a possible drug allergy, because history is not enough to certify the diagnosis. To do a provocation test to a negative protocol is crucial.

  5. Evaluation of a rapid protocol for the assessment of salt sensitivity against the blood pressure response to dietary sodium chloride restriction.

    PubMed

    Galletti, F; Ferrara, I; Stinga, F; Iacone, R; Noviello, F; Strazzullo, P

    1997-04-01

    The "gold standard" for the assessment of salt sensitivity of hypertension is the blood pressure response to dietary NaCl restriction; nevertheless, for practical purposes, a more rapid test that would not depend on the patient's compliance to the dietary prescription would be very useful in clinical research and medical practice. The aim of this study was thus to evaluate the effectiveness and reliability of a rapid, easy-to-standardize protocol for the assessment of salt sensitivity against the blood pressure response to dietary salt restriction. A total of 108 hypertensive patients were screened for salt sensitivity by the modified protocol of Grim et al. Thereafter, nine patients identified by the test as salt sensitive and nine identified as salt resistant followed, for two consecutive periods of 1 week, a diet with normal (200 mmol/day) or low (50 mmol/day) NaCl content. Compliance to the diet was checked by repeated 24-h urine collections. The group as a whole experienced a significant fall in blood pressure during the low Na diet (mean pressure = 123 +/- 3 v 118 +/- 3 mm Hg; P < .05). However, whereas patients identified as salt sensitive by the Grim protocol had a marked and significant blood pressure decrease (systolic -12 mm Hg, diastolic -7 mm Hg), no change was observed in those classified as salt resistant (systolic -2 mm Hg, diastolic -2 mm Hg). A significant correlation between changes in urinary Na excretion and changes in blood pressure was found only in salt-sensitive hypertensive patients. In conclusion, the modified Grim protocol tested in this study was able to correctly predict a significant blood pressure response to dietary salt restriction in the majority of cases. A validation of this test in a larger patient population may be advisable.

  6. Soil pH Mapping with an On-The-Go Sensor

    PubMed Central

    Schirrmann, Michael; Gebbers, Robin; Kramer, Eckart; Seidel, Jan

    2011-01-01

    Soil pH is a key parameter for crop productivity, therefore, its spatial variation should be adequately addressed to improve precision management decisions. Recently, the Veris pH Manager™, a sensor for high-resolution mapping of soil pH at the field scale, has been made commercially available in the US. While driving over the field, soil pH is measured on-the-go directly within the soil by ion selective antimony electrodes. The aim of this study was to evaluate the Veris pH Manager™ under farming conditions in Germany. Sensor readings were compared with data obtained by standard protocols of soil pH assessment. Experiments took place under different scenarios: (a) controlled tests in the lab, (b) semicontrolled test on transects in a stop-and-go mode, and (c) tests under practical conditions in the field with the sensor working in its typical on-the-go mode. Accuracy issues, problems, options, and potential benefits of the Veris pH Manager™ were addressed. The tests demonstrated a high degree of linearity between standard laboratory values and sensor readings. Under practical conditions in the field (scenario c), the measure of fit (r2) for the regression between the on-the-go measurements and the reference data was 0.71, 0.63, and 0.84, respectively. Field-specific calibration was necessary to reduce systematic errors. Accuracy of the on-the-go maps was considerably higher compared with the pH maps obtained by following the standard protocols, and the error in calculating lime requirements was reduced by about one half. However, the system showed some weaknesses due to blockage by residual straw and weed roots. If these problems were solved, the on-the-go sensor investigated here could be an efficient alternative to standard sampling protocols as a basis for liming in Germany. PMID:22346591

  7. Soil pH mapping with an on-the-go sensor.

    PubMed

    Schirrmann, Michael; Gebbers, Robin; Kramer, Eckart; Seidel, Jan

    2011-01-01

    Soil pH is a key parameter for crop productivity, therefore, its spatial variation should be adequately addressed to improve precision management decisions. Recently, the Veris pH Manager™, a sensor for high-resolution mapping of soil pH at the field scale, has been made commercially available in the US. While driving over the field, soil pH is measured on-the-go directly within the soil by ion selective antimony electrodes. The aim of this study was to evaluate the Veris pH Manager™ under farming conditions in Germany. Sensor readings were compared with data obtained by standard protocols of soil pH assessment. Experiments took place under different scenarios: (a) controlled tests in the lab, (b) semicontrolled test on transects in a stop-and-go mode, and (c) tests under practical conditions in the field with the sensor working in its typical on-the-go mode. Accuracy issues, problems, options, and potential benefits of the Veris pH Manager™ were addressed. The tests demonstrated a high degree of linearity between standard laboratory values and sensor readings. Under practical conditions in the field (scenario c), the measure of fit (r(2)) for the regression between the on-the-go measurements and the reference data was 0.71, 0.63, and 0.84, respectively. Field-specific calibration was necessary to reduce systematic errors. Accuracy of the on-the-go maps was considerably higher compared with the pH maps obtained by following the standard protocols, and the error in calculating lime requirements was reduced by about one half. However, the system showed some weaknesses due to blockage by residual straw and weed roots. If these problems were solved, the on-the-go sensor investigated here could be an efficient alternative to standard sampling protocols as a basis for liming in Germany.

  8. Validation of the G.LAB MD2200 wrist blood pressure monitor according to the European Society of Hypertension, the British Hypertension Society, and the International Organization for Standardization Protocols.

    PubMed

    Liu, Ze-Yu; Zhang, Qing-Han; Ye, Xiao-Lei; Liu, Da-Peng; Cheng, Kang; Zhang, Chun-Hai; Wan, Yi

    2017-04-01

    To validate the G.LAB MD2200 automated wrist blood pressure (BP) monitors according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010, the British Hypertension Society (BHS), and the International Organization for Standardization (ISO) 81060-2:2013 protocols. The device was assessed on 33 participants according to the ESH requirements and was then tested on 85 participants according to the BHS and ISO 81060-2:2013 criteria. The validation procedures and data analysis followed the protocols precisely. The G.LAB MD2200 devices passed all parts of ESH-IP revision 2010 for both systolic and diastolic BP, with a device-observer difference of 2.15±5.51 and 1.51±5.16 mmHg, respectively. The device achieved A/A grading for the BHS protocol and it also fulfilled the criteria of ISO 81060-2:2013, with mean differences of systolic and diastolic BP between the device and the observer of 2.19±5.21 and 2.11±4.70 mmHg, respectively. The G.LAB MD2200 automated wrist BP monitor passed the ESH-IP revision 2010 and the ISO 81060-2:2013 protocol, and achieved the A/A grade of the BHS protocol, which can be recommended for self-measurement in the general population.

  9. Evaluation of hyperketonemia risk period and screening protocols for early-lactation dairy cows.

    PubMed

    Mahrt, A; Burfeind, O; Heuwieser, W

    2015-05-01

    The objectives of this study were to describe the onset of hyperketonemia, the number of positive hyperketonemia test results, and the duration of the longest hyperketonemic period during the first 42 d in milk (DIM) in dairy cows. Furthermore, we set out to evaluate test characteristics of single and repeated measurements of β-hydroxybutyric acid (BHBA) during this period to diagnose hyperketonemia. Using an electronic handheld meter, 252 cows from 3 farms were tested twice weekly for hyperketonemia (blood BHBA ≥1.2 mmol/L) during the first 42 DIM, resulting in 12 test results per cow (i.e., in lactation wk 0.5 to 6). Prevalence and incidence of hyperketonemia were calculated for the 12 examination days and the 42-d period, respectively. Test characteristics for the diagnosis of hyperketonemia were calculated for 4 different testing scenarios (testing all cows 1, 2, 3, or 6 times during the first 42 DIM) and 2 different gold-standard definitions (BHBA ≥1.2 mmol/L at least once during the observation period or BHBA ≥1.2 mmol/L at least twice during the observation period). Mean prevalence of hyperketonemia was 11.8%, ranging from 9.6% in lactation wk 0.5 and 2.0 to 14.6% in lactation wk 5.5. In total, 134 cows (53.2%) had at least 1 positive hyperketonemia test result during the whole 42-d period. Of these cows, 46.3% had only 1 positive result. The median first positive hyperketonemia test result was in lactation wk 2.0 [interquartile range (IQR) 1.0-3.5]. Median frequency of positive test results in cows affected by hyperketonemia was 2 positive test results (IQR 1-3). Median duration of the longest hyperketonemic period per cow affected was 1 examination interval (3-4 d; IQR 1-2). Considering a minimum of 1 positive hyperketonemia test result during the first 42 DIM as the gold standard, sensitivity of a single BHBA measurement during this period to diagnose hyperketonemia was 21%. A weekly testing protocol had a sensitivity of 72%. Specificity was 100% in both cases. Considering a minimum of 2 positive hyperketonemia test results as the gold standard, sensitivity and specificity of a single BHBA measurement during the first 42 DIM were 33 and 97%, respectively. A weekly testing protocol provided sensitivity and specificity of 91 and 83%, respectively. We conclude that the risk period for hyperketonemia lasts at least until lactation wk 6, which should be considered when planning hyperketonemia screening programs. Test characteristics of screening protocols depend on testing frequency. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  10. CPM Test-Retest Reliability: "Standard" vs "Single Test-Stimulus" Protocols.

    PubMed

    Granovsky, Yelena; Miller-Barmak, Adi; Goldstein, Oren; Sprecher, Elliot; Yarnitsky, David

    2016-03-01

    Assessment of pain inhibitory mechanisms using conditioned pain modulation (CPM) is relevant clinically in prediction of pain and analgesic efficacy. Our objective is to provide necessary estimates of intersession CPM reliability, to enable transformation of the CPM paradigm into a clinical tool. Two cohorts of young healthy subjects (N = 65) participated in two dual-session studies. In Study I, a Bath-Thermode CPM protocol was used, with hot water immersion and contact heat as conditioning- and test-stimuli, respectively, in a classical parallel CPM design introducing test-stimulus first, and then the conditioning- and repeated test-stimuli in parallel. Study II consisted of two CPM protocols: 1) Two-Thermodes, one for each of the stimuli, in the same parallel design as above, and 2) single test-stimulus (STS) protocol with a single administration of a contact heat test-stimulus, partially overlapped in time by a remote shorter contact heat as conditioning stimulus. Test-retest reliability was assessed within 3-7 days. The STS-CPM had superior reliability intraclass correlation (ICC 2 ,: 1  = 0.59) over Bath-Thermode (ICC 2 ,: 1  = 0.34) or Two-Thermodes (ICC 2 ,: 1  = 0.21) protocols. The hand immersion conditioning pain had higher reliability than thermode pain (ICC 2 ,: 1  = 0.76 vs ICC 2 ,: 1  = 0.16). Conditioned test-stimulus pain scores were of good (ICC 2 ,: 1  = 0.62) or fair (ICC 2 ,: 1  = 0.43) reliability for the Bath-Thermode and the STS, respectively, but not for the Two-Thermodes protocol (ICC 2 ,: 1  = 0.20). The newly developed STS-CPM paradigm was more reliable than other CPM protocols tested here, and should be further investigated for its clinical relevance. It appears that large contact size of the conditioning-stimulus and use of single rather than dual test-stimulus pain contribute to augmentation of CPM reliability. © 2015 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  11. IPHE Regulations Codes and Standards Working Group - Type IV COPV Round Robin Testing

    NASA Technical Reports Server (NTRS)

    Maes, M.; Starritt, L.; Zheng, J. Y.; Ou, K.; Keller, J.

    2017-01-01

    This manuscript presents the results of a multi-lateral international activity intended to understand how to execute a cycle stress test as specified in a chosen standard (GTR, SAE, ISO, EIHP...). The purpose of this work was to establish a harmonized test method protocol to ensure that the same results would be achieved regardless of the testing facility. It was found that accurate temperature measurement of the working fluid is necessary to ensure the test conditions remain within the tolerances specified. Continuous operation is possible with adequate cooling of the working fluid but this becomes more demanding if the cycle frequency increases. Recommendations for future test system design and operation are presented.

  12. An inter- laboratory proficiency testing exercise for rabies diagnosis in Latin America and the Caribbean

    PubMed Central

    Clavijo, Alfonso; Freire de Carvalho, Mary H.; Orciari, Lillian A.; Velasco-Villa, Andres; Ellison, James A.; Greenberg, Lauren; Yager, Pamela A.; Green, Douglas B.; Vigilato, Marco A.; Cosivi, Ottorino; Del Rio-Vilas, Victor J.

    2017-01-01

    The direct fluorescent antibody test (DFA), is performed in all rabies reference laboratories across Latin America and the Caribbean (LAC). Despite DFA being a critical capacity in the control of rabies, there is not a standardized protocol in the region. We describe the results of the first inter-laboratory proficiency exercise of national rabies laboratories in LAC countries as part of the regional efforts towards dog-maintained rabies elimination in the American region. Twenty three laboratories affiliated to the Ministries of Health and Ministries of Agriculture participated in this exercise. In addition, the laboratories completed an online questionnaire to assess laboratory practices. Answers to the online questionnaire indicated large variability in the laboratories throughput, equipment used, protocols availability, quality control standards and biosafety requirements. Our results will inform actions to improve and harmonize laboratory rabies capacities across LAC in support for the regional efforts towards elimination of dog-maintained rabies. PMID:28369139

  13. Protocol for Uniformly Measuring and Expressing the Performance of Energy Storage Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Conover, David R.; Crawford, Aladsair J.; Fuller, Jason C.

    The Protocol for Uniformly Measuring and Expressing the Performance of Energy Storage Systems (PNNL-22010) was first issued in November 2012 as a first step toward providing a foundational basis for developing an initial standard for the uniform measurement and expression of energy storage system (ESS) performance. Based on experiences with the application and use of that document, and to include additional ESS applications and associated duty cycles, test procedures and performance metrics, a first revision of the November 2012 Protocol was issued in June 2014 (PNNL 22010 Rev. 1). As an update of the 2014 revision 1 to the Protocol,more » this document (the March 2016 revision 2 to the Protocol) is intended to supersede the June 2014 revision 1 to the Protocol and provide a more user-friendly yet more robust and comprehensive basis for measuring and expressing ESS performance.« less

  14. [Validation of plasma creatinine measurement on UniCel DxC 600 according to LAB GTA 04 recommendation].

    PubMed

    Chianea, Denis; Renard, Christophe; Garcia, Carine; Mbongo, Elvire; Monpeurt, Corine; Vest, Philippe

    2010-01-01

    The accreditation process, according to NF EN ISO 15189, implies a prior evaluation of the new reagent on-site for the implementation of each new assay technique. Thus, our new standardized method for determination of creatinine (non compensated method) in plasma or serum on UniCel DxC 600 (Beckman Coulter) has been tested according to LAB GTA 04 protocol. The reagent meets the quality criteria recommended by Valtec protocol, except fidelity with the low concentration standard (50 micromol/L). Besides there is no problem of results transferability with the two other techniques used in the laboratory (Jaffe compensated and enzymatic methods performed on Cobas Integra 800).

  15. A Standardized Shift Handover Protocol: Improving Nurses’ Safe Practice in Intensive Care Units

    PubMed Central

    Malekzadeh, Javad; Mazluom, Seyed Reza; Etezadi, Toktam; Tasseri, Alireza

    2013-01-01

    Introduction: For maintaining the continuity of care and improving the quality of care, effective inter-shift information communication is necessary. Any handover error can endanger patient safety. Despite the importance of shift handover, there is no standard handover protocol in our healthcare settings. Methods: In this one-group pretest-posttest quasi-experimental study conducted in spring and summer of 2011, we recruited a convenience sample of 56 ICU nurses. The Nurses’ Safe Practice Evaluation Checklist was used for data collection. The Content Validity Index and the inter-rater correlation coefficient of the checklist was 0.92 and 89, respectively. We employed the SPSS 11.5 software and the Mc Nemar and paired-samples t test for data analysis. Results: Study findings revealed that nurses’ mean score on the Safe Practice Evaluation Checklist increased significantly from 11.6 (2.7) to 17.0 (1.8) (P < 0.001). Conclusion: using a standard handover protocol for communicating patient’s needs and information improves nurses’ safe practice in the area of basic nursing care. PMID:25276725

  16. Publication trends of study protocols in rehabilitation.

    PubMed

    Jesus, Tiago S; Colquhoun, Heather L

    2017-09-04

    Growing evidence points for the need to publish study protocols in the health field. To observe whether the growing interest in publishing study protocols in the broader health field has been translated into increased publications of rehabilitation study protocols. Observational study using publication data and its indexation in PubMed. Not applicable. Not applicable. PubMed was searched with appropriate combinations of Medical Subject Headings up to December 2014. The effective presence of study protocols was manually screened. Regression models analyzed the yearly growth of publications. Two-sample Z-tests analyzed whether the proportion of Systematic Reviews (SRs) and Randomized Controlled Trials (RCTs) among study protocols differed from that of the same designs for the broader rehabilitation research. Up to December 2014, 746 publications of rehabilitation study protocols were identified, with an exponential growth since 2005 (r2=0.981; p<0.001). RCT protocols were the most common among rehabilitation study protocols (83%), while RCTs were significantly more prevalent among study protocols than among the broader rehabilitation research (83% vs. 35.8%; p<0.001). For SRs, the picture was reversed: significantly less common among study protocols (2.8% vs. 9.3%; p<0.001). Funding was more often reported by rehabilitation study protocols than the broader rehabilitation research (90% vs. 53.1%; p<0.001). Rehabilitation journals published a significantly lower share of rehabilitation study protocols than they did for the broader rehabilitation research (1.8% vs.16.7%; p<0.001). Identifying the reasons for these discrepancies and reverting unwarranted disparities (e.g. low rate of publication for rehabilitation SR protocols) are likely new avenues for rehabilitation research and its publication. SRs, particularly those aggregating RCT results, are considered the best standard of evidence to guide rehabilitation clinical practice; however, that standard can be improved in rigor and/or transparency if the publications of rehabilitation SRs protocols become more common.

  17. Validation of a standardized extraction method for formalin-fixed paraffin-embedded tissue samples.

    PubMed

    Lagheden, Camilla; Eklund, Carina; Kleppe, Sara Nordqvist; Unger, Elizabeth R; Dillner, Joakim; Sundström, Karin

    2016-07-01

    Formalin-fixed paraffin-embedded (FFPE) samples can be DNA-extracted and used for human papillomavirus (HPV) genotyping. The xylene-based gold standard for extracting FFPE samples is laborious, suboptimal and involves health hazards for the personnel involved. To compare extraction with the standard xylene method to a xylene-free method used in an HPV LabNet Global Reference Laboratory at the Centers for Disease Control (CDC); based on a commercial method with an extra heating step. Fifty FFPE samples were randomly selected from a national audit of all cervical cancer cases diagnosed in Sweden during 10 years. For each case-block, a blank-block was sectioned, as a control for contamination. For xylene extraction, the standard WHO Laboratory Manual protocol was used. For the CDC method, the manufacturers' protocol was followed except for an extra heating step, 120°C for 20min. Samples were extracted and tested in parallel with β-globin real-time PCR, HPV16 real-time PCR and HPV typing using modified general primers (MGP)-PCR and Luminex assays. For a valid result the blank-block had to be betaglobin-negative in all tests and the case-block positive for beta-globin. Overall, detection was improved with the heating method and the amount of HPV-positive samples increased from 70% to 86% (p=0.039). For all samples where HPV type concordance could be evaluated, there was 100% type concordance. A xylene-free and robust extraction method for HPV-DNA typing in FFPE material is currently in great demand. Our proposed standardized protocol appears to be generally useful. Copyright © 2016. Published by Elsevier B.V.

  18. Heart-Rate Recovery After Warm-up in Swimming: A Useful Predictor of Training Heart-Rate Response?

    PubMed

    Ganzevles, Sander P M; de Haan, Arnold; Beek, Peter J; Daanen, Hein A M; Truijens, Martin J

    2017-07-01

    For training to be optimal, daily training load has to be adapted to the momentary status of the individual athlete, which is often difficult to establish. Therefore, the current study investigated the predictive value of heart-rate recovery (HRR) during a standardized warm-up for training load. Training load was quantified by the variation in heart rate during standardized training in competitive swimmers. Eight female and 5 male Dutch national-level swimmers participated in the study. They all performed 3 sessions consisting of a 300-m warm-up test and a 10 × 100-m training protocol. Both protocols were swum in front crawl at individually standardized velocities derived from an incremental step test. Velocity was related to 75% and 85% heart-rate reserve (% HR res ) for the warm-up and training, respectively. Relative HRR during the first 60 s after the warm-up (HR Rw-up ) and differences between the actual and intended heart rate for the warm-up and the training (ΔHR w-up and ΔHR tr ) were determined. No significant relationship between HRR w-up and ΔHR tr was found (F 1,37 = 2.96, P = .09, R 2 = .07, SEE = 4.65). There was considerable daily variation in ΔHR tr at a given swimming velocity (73-93% HR res ). ΔHR w-up and ΔHR tr were clearly related (F 1,37 = 74.31, P < .001, R 2 = .67, SEE = 2.78). HRR after a standardized warm-up does not predict heart rate during a directly subsequent and standardized training session. Instead, heart rate during the warm-up protocol seems a promising alternative for coaches to make daily individual-specific adjustments to training programs.

  19. Action Observation Plus Sonification. A Novel Therapeutic Protocol for Parkinson’s Patient with Freezing of Gait

    PubMed Central

    Mezzarobba, Susanna; Grassi, Michele; Pellegrini, Lorella; Catalan, Mauro; Kruger, Bjorn; Furlanis, Giovanni; Manganotti, Paolo; Bernardis, Paolo

    2018-01-01

    Freezing of gait (FoG) is a disabling symptom associated with falls, with little or no responsiveness to pharmacological treatment. Current protocols used for rehabilitation are based on the use of external sensory cues. However, cued strategies might generate an important dependence on the environment. Teaching motor strategies without cues [i.e., action observation (AO) plus Sonification] could represent an alternative/innovative approach to rehabilitation that matters most on appropriate allocation of attention and lightening cognitive load. We aimed to test the effects of a novel experimental protocol to treat patients with Parkinson’s disease (PD) and FoG, using functional, and clinical scales. The experimental protocol was based on AO plus Sonification. 12 patients were treated with 8 motor gestures. They watched eight videos showing an actor performing the same eight gestures, and then tried to repeat each gesture. Each video was composed by images and sounds of the gestures. By means of the Sonification technique, the sounds of gestures were obtained by transforming kinematic data (velocity) recorded during gesture execution, into pitch variations. The same 8 motor gestures were also used in a second group of 10 patients; which were treated with a standard protocol based on a common sensory stimulation method. All patients were tested with functional and clinical scales before, after, at 1 month, and 3 months after the treatment. Data showed that the experimental protocol have positive effects on functional and clinical tests. In comparison with the baseline evaluations, significant performance improvements were seen in the NFOG questionnaire, and the UPDRS (parts II and III). Importantly, all these improvements were consistently observed at the end, 1 month, and 3 months after treatment. No improvement effects were found in the group of patients treated with the standard protocol. These data suggest that a multisensory approach based on AO plus Sonification, with the two stimuli semantically related, could help PD patients with FoG to relearn gait movements, to reduce freezing episodes, and that these effects could be prolonged over time. PMID:29354092

  20. Accuracy of computer-aided design models of the jaws produced using ultra-low MDCT doses and ASIR and MBIR.

    PubMed

    Al-Ekrish, Asma'a A; Alfadda, Sara A; Ameen, Wadea; Hörmann, Romed; Puelacher, Wolfgang; Widmann, Gerlig

    2018-06-16

    To compare the surface of computer-aided design (CAD) models of the maxilla produced using ultra-low MDCT doses combined with filtered backprojection (FBP), adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR) reconstruction techniques with that produced from a standard dose/FBP protocol. A cadaveric completely edentulous maxilla was imaged using a standard dose protocol (CTDIvol: 29.4 mGy) and FBP, in addition to 5 low dose test protocols (LD1-5) (CTDIvol: 4.19, 2.64, 0.99, 0.53, and 0.29 mGy) reconstructed with FBP, ASIR 50, ASIR 100, and MBIR. A CAD model from each test protocol was superimposed onto the reference model using the 'Best Fit Alignment' function. Differences between the test and reference models were analyzed as maximum and mean deviations, and root-mean-square of the deviations, and color-coded models were obtained which demonstrated the location, magnitude and direction of the deviations. Based upon the magnitude, size, and distribution of areas of deviations, CAD models from the following protocols were comparable to the reference model: FBP/LD1; ASIR 50/LD1 and LD2; ASIR 100/LD1, LD2, and LD3; MBIR/LD1. The following protocols demonstrated deviations mostly between 1-2 mm or under 1 mm but over large areas, and so their effect on surgical guide accuracy is questionable: FBP/LD2; MBIR/LD2, LD3, LD4, and LD5. The following protocols demonstrated large deviations over large areas and therefore were not comparable to the reference model: FBP/LD3, LD4, and LD5; ASIR 50/LD3, LD4, and LD5; ASIR 100/LD4, and LD5. When MDCT is used for CAD models of the jaws, dose reductions of 86% may be possible with FBP, 91% with ASIR 50, and 97% with ASIR 100. Analysis of the stability and accuracy of CAD/CAM surgical guides as directly related to the jaws is needed to confirm the results.

  1. Bedside diagnosis of dysphagia: a systematic review.

    PubMed

    O'Horo, John C; Rogus-Pulia, Nicole; Garcia-Arguello, Lisbeth; Robbins, JoAnne; Safdar, Nasia

    2015-04-01

    Dysphagia is associated with aspiration, pneumonia, and malnutrition, but remains challenging to identify at the bedside. A variety of exam protocols and maneuvers are commonly used, but the efficacy of these maneuvers is highly variable. We conducted a comprehensive search of 7 databases, including MEDLINE, Embase, and Scopus, from each database's earliest inception through June 9, 2014. Studies reporting diagnostic performance of a bedside examination maneuver compared to a reference gold standard (videofluoroscopic swallow study or flexible endoscopic evaluation of swallowing with sensory testing) were included for analysis. From each study, data were abstracted based on the type of diagnostic method and reference standard study population and inclusion/exclusion characteristics, design, and prediction of aspiration. The search strategy identified 38 articles meeting inclusion criteria. Overall, most bedside examinations lacked sufficient sensitivity to be used for screening purposes across all patient populations examined. Individual studies found dysphonia assessments, abnormal pharyngeal sensation assessments, dual axis accelerometry, and 1 description of water swallow testing to be sensitive tools, but none were reported as consistently sensitive. A preponderance of identified studies was in poststroke adults, limiting the generalizability of results. No bedside screening protocol has been shown to provide adequate predictive value for presence of aspiration. Several individual exam maneuvers demonstrated reasonable sensitivity, but reproducibility and consistency of these protocols was not established. More research is needed to design an optimal protocol for dysphagia detection. © 2015 Society of Hospital Medicine.

  2. Novel methods of imaging and analysis for the thermoregulatory sweat test.

    PubMed

    Carroll, Michael Sean; Reed, David W; Kuntz, Nancy L; Weese-Mayer, Debra Ellyn

    2018-06-07

    The thermoregulatory sweat test (TST) can be central to the identification and management of disorders affecting sudomotor function and small sensory and autonomic nerve fibers, but the cumbersome nature of the standard testing protocol has prevented its widespread adoption. A high resolution, quantitative, clean and simple assay of sweating could significantly improve identification and management of these disorders. Images from 89 clinical TSTs were analyzed retrospectively using two novel techniques. First, using the standard indicator powder, skin surface sweat distributions were determined algorithmically for each patient. Second, a fundamentally novel method using thermal imaging of forced evaporative cooling was evaluated through comparison with the standard technique. Correlation and receiver operating characteristic analyses were used to determine the degree of match between these methods, and the potential limits of thermal imaging were examined through cumulative analysis of all studied patients. Algorithmic encoding of sweating and non-sweating regions produces a more objective analysis for clinical decision making. Additionally, results from the forced cooling method correspond well with those from indicator powder imaging, with a correlation across spatial regions of -0.78 (CI: -0.84 to -0.71). The method works similarly across body regions, and frame-by-frame analysis suggests the ability to identify sweating regions within about 1 second of imaging. While algorithmic encoding can enhance the standard sweat testing protocol, thermal imaging with forced evaporative cooling can dramatically improve the TST by making it less time-consuming and more patient-friendly than the current approach.

  3. CT and MR Protocol Standardization Across a Large Health System: Providing a Consistent Radiologist, Patient, and Referring Provider Experience.

    PubMed

    Sachs, Peter B; Hunt, Kelly; Mansoubi, Fabien; Borgstede, James

    2017-02-01

    Building and maintaining a comprehensive yet simple set of standardized protocols for a cross-sectional image can be a daunting task. A single department may have difficulty preventing "protocol creep," which almost inevitably occurs when an organized "playbook" of protocols does not exist and individual radiologists and technologists alter protocols at will and on a case-by-case basis. When multiple departments or groups function in a large health system, the lack of uniformity of protocols can increase exponentially. In 2012, the University of Colorado Hospital formed a large health system (UCHealth) and became a 5-hospital provider network. CT and MR imaging studies are conducted at multiple locations by different radiology groups. To facilitate consistency in ordering, acquisition, and appearance of a given study, regardless of location, we minimized the number of protocols across all scanners and sites of practice with a clinical indication-driven protocol selection and standardization process. Here we review the steps utilized to perform this process improvement task and insure its stability over time. Actions included creation of a standardized protocol template, which allowed for changes in electronic storage and management of protocols, designing a change request form, and formation of a governance structure. We utilized rapid improvement events (1 day for CT, 2 days for MR) and reduced 248 CT protocols into 97 standardized protocols and 168 MR protocols to 66. Additional steps are underway to further standardize output and reporting of imaging interpretation. This will result in an improved, consistent radiologist, patient, and provider experience across the system.

  4. Anticarcinogenic effect of betel leaf extract against tobacco carcinogens.

    PubMed

    Padma, P R; Lalitha, V S; Amonkar, A J; Bhide, S V

    1989-06-01

    Epidemiological studies have implicated that betel quid offers some protection to tobacco induced carcinogenesis. Earlier studies in our laboratory have shown betel leaf extract (BLE) to be antimutagenic against standard mutagens and tobacco-specific N'-nitrosamines (TSNA), N'-nitrosonornicotine (NNN) and 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK). In the present study, we have tested the anticarcinogenic effect of BLE using Swiss male mice. Two protocols of study were used to test this effect. In the first protocol, the effect of BLE was tested against the standard carcinogen benzo[a]pyrene (BP) using Wattenberg's stomach tumor model, Cancer Res., 41 (1981) 2820-2823. In this protocol, BLE inhibited the tumorigenicity of BP to a significant extent. In the second protocol, the effect of BLE against the two tobacco-specific nitrosamines, NNN and NNK was studied using long-term studies on Swiss male mice. The nitrosamines were administered on the tongues of the mice, while the BLE was supplied in drinking water. Two doses of NNN (22 mg and 72 mg) and one dose of NNK (22 mg) were used. In this study, it was observed that the number of tumor bearing animals decreased, but the difference was significant only in the group treated with the low dose of NNN in combination with BLE. However, in all the BLE treated animals, irrespective of the dose of nitrosamine, the hepatic vitamin A and C levels were elevated significantly as compared to the corresponding nitrosamine-treated controls. These results indicate that BLE has a promising anticarcinogenic role to play in tobacco induced cancer.(ABSTRACT TRUNCATED AT 250 WORDS)

  5. Boldness, Aggression, and Shoaling Assays for Zebrafish Behavioral Syndromes.

    PubMed

    Way, Gregory P; Southwell, Maura; McRobert, Scott P

    2016-08-29

    A behavioral syndrome exists when specific behaviors interact under different contexts. Zebrafish have been test subjects in recent studies and it is important to standardize protocols to ensure proper analyses and interpretations. In our previous studies, we have measured boldness by monitoring a series of behaviors (time near surface, latency in transitions, number of transitions, and darts) in a 1.5 L trapezoidal tank. Likewise, we quantified aggression by observing bites, lateral displays, darts, and time near an inclined mirror in a rectangular 19 L tank. By dividing a 76 L tank into thirds, we also examined shoaling preferences. The shoaling assay is a highly customizable assay and can be tailored for specific hypotheses. However, protocols for this assay also must be standardized, yet flexible enough for customization. In previous studies, end chambers were either empty, contained 5 or 10 zebrafish, or 5 pearl danios (D. albolineatus). In the following manuscript, we present a detailed protocol and representative data that accompany successful applications of the protocol, which will allow for replication of behavioral syndrome experiments.

  6. Experimental Evaluation of Unicast and Multicast CoAP Group Communication

    PubMed Central

    Ishaq, Isam; Hoebeke, Jeroen; Moerman, Ingrid; Demeester, Piet

    2016-01-01

    The Internet of Things (IoT) is expanding rapidly to new domains in which embedded devices play a key role and gradually outnumber traditionally-connected devices. These devices are often constrained in their resources and are thus unable to run standard Internet protocols. The Constrained Application Protocol (CoAP) is a new alternative standard protocol that implements the same principals as the Hypertext Transfer Protocol (HTTP), but is tailored towards constrained devices. In many IoT application domains, devices need to be addressed in groups in addition to being addressable individually. Two main approaches are currently being proposed in the IoT community for CoAP-based group communication. The main difference between the two approaches lies in the underlying communication type: multicast versus unicast. In this article, we experimentally evaluate those two approaches using two wireless sensor testbeds and under different test conditions. We highlight the pros and cons of each of them and propose combining these approaches in a hybrid solution to better suit certain use case requirements. Additionally, we provide a solution for multicast-based group membership management using CoAP. PMID:27455262

  7. Legal and ethical aspects of deliberate G-induced loss of consciousness experiments.

    PubMed

    Euretig, J G

    1991-07-01

    Informed consent is both a legal and accepted ethical prerequisite to nontherapeutic human experimentation. The informed consent obtained from the subject in G-LOC experimentation is in the same form as the risk disclosures used in high-G acceleration experiments. However, in high acceleration protocols G-LOC is a potential risk while in G-LOC experiments it is the result. The case law embodies three modern evidentiary standards (the "professional," "material fact," and "possible risks" tests) employed by common law courts when deciding whether the risk disclosures are sufficient to elicit the informed consent of the subject. Each standard is applied against the disclosures in the G-LOC protocol to determine if the elements of the requirement are met. The risk disclosures are wanting in specific identification under the three tests. The deficiency is the failure to inform the subject that G-LOC may result in a pathologic state of unconsciousness about which little is known. Without complete disclosure of this lacking state of medical knowledge, it is questionable whether informed consent can be given. If subjected to judicial scrutiny, the disclosures stated in the G-LOC protocol used in government sponsored research will probably be found deficient.

  8. A multilevel Lab on chip platform for DNA analysis.

    PubMed

    Marasso, Simone Luigi; Giuri, Eros; Canavese, Giancarlo; Castagna, Riccardo; Quaglio, Marzia; Ferrante, Ivan; Perrone, Denis; Cocuzza, Matteo

    2011-02-01

    Lab-on-chips (LOCs) are critical systems that have been introduced to speed up and reduce the cost of traditional, laborious and extensive analyses in biological and biomedical fields. These ambitious and challenging issues ask for multi-disciplinary competences that range from engineering to biology. Starting from the aim to integrate microarray technology and microfluidic devices, a complex multilevel analysis platform has been designed, fabricated and tested (All rights reserved-IT Patent number TO2009A000915). This LOC successfully manages to interface microfluidic channels with standard DNA microarray glass slides, in order to implement a complete biological protocol. Typical Micro Electro Mechanical Systems (MEMS) materials and process technologies were employed. A silicon/glass microfluidic chip and a Polydimethylsiloxane (PDMS) reaction chamber were fabricated and interfaced with a standard microarray glass slide. In order to have a high disposable system all micro-elements were passive and an external apparatus provided fluidic driving and thermal control. The major microfluidic and handling problems were investigated and innovative solutions were found. Finally, an entirely automated DNA hybridization protocol was successfully tested with a significant reduction in analysis time and reagent consumption with respect to a conventional protocol.

  9. Protocols for hyperlactatemia induction in the lactate minimum test adapted to swimming rats.

    PubMed

    de Araujo, Gustavo Gomes; Papoti, Marcelo; Manchado, Fúlvia de Barros; de Mello, Maria Alice Rostom; Gobatto, Claudio Alexandre

    2007-12-01

    The lactate minimum test (LACmin) has been considered an important indicator of endurance exercise capacity and a single session protocol can predict the maximal steady state lactate (MLSS). The objective of this study was to determine the best swimming protocol to induce hyperlactatemia in order to assure the LACmin in rats (Rattus norvegicus), standardized to four different protocols (P) of lactate elevation. The protocols were P1: 6 min of intermittent jumping exercise in water (load of 50% of the body weight - bw); P2: two 13% bw load swimming bouts until exhaustion (tlim); P3: one tlim 13% bw load swimming bout; and P4: two 13% bw load swimming bouts (1st 30 s, 2nd to tlim), separated by a 30 s interval. The incremental phase of LACmin beginning with initial loads of 4% bw, increased in 0.5% at each 5 min. Peak lactate concentration was collected after 5, 7 and 9 min (mmol L(-1)) and differed among the protocols P1 (15.2+/-0.4, 14.9+/-0.7, 14.8+/-0.6) and P2 (14.0+/-0.4, 14.9+/-0.4, 15.5+/-0.5) compared to P3 (5.1+/-0.1, 5.6+/-0.3, 5.6+/-0.3) and P4 (4.7+/-0.2, 6.8+/-0.2, 7.1+/-0.2). The LACmin determination success rates were 58%, 55%, 80% and 91% in P1, P2, P3 and P4 protocols, respectively. The MLSS did not differ from LACmin in any protocol. The LACmin obtained from P4 protocol showed better assurance for the MLSS identification in most of the tested rats.

  10. Porcelain surface conditioning protocols and shear bond strength of orthodontic brackets.

    PubMed

    Lestrade, Ashley M; Ballard, Richard W; Xu, Xiaoming; Yu, Qingzhao; Kee, Edwin L; Armbruster, Paul C

    2016-05-01

    The objective of the present study was to determine which of six bonding protocols yielded a clinically acceptable shear bond strength (SBS) of metal orthodontic brackets to CAD/CAM lithium disilicate porcelain restorations. A secondary aim was to determine which bonding protocol produced the least surface damage at debond. Sixty lithium disilicate samples were fabricated to replicate the facial surface of a mandibular first molar using a CEREC CAD/CAM machine. The samples were split into six test groups, each of which received different mechanical/chemical pretreatment protocols to roughen the porcelain surface prior to bonding a molar orthodontic attachment. Shear bond strength testing was conducted using an Instron machine. The mean, maximum, minimal, and standard deviation SBS values for each sample group including an enamel control were calculated. A t-test was used to evaluate the statistical significance between the groups. No significant differences were found in SBS values, with the exception of surface roughening with a green stone prior to HFA and silane treatment. This protocol yielded slightly higher bond strength which was statistically significant. Chemical treatment alone with HFA/silane yielded SBS values within an acceptable clinical range to withstand forces applied by orthodontic treatment and potentially eliminates the need to mechanically roughen the ceramic surface.

  11. Performance Evaluation of a PEM Scanner Using the NEMA NU 4—2008 Small Animal PET Standards

    NASA Astrophysics Data System (ADS)

    Luo, Weidong; Anashkin, Edward; Matthews, Christopher G.

    2010-02-01

    The recently published NEMA NU 4-2008 Standards has been specially designed for evaluating the performance of small animal PET scanners used in preclinical applications. In this paper, we report on the NU 4 performance of a clinical positron emission mammography (PEM) system. Since there are no PEM specific performance test protocols available, and the NU 2 protocol (intended for whole-body PET scanners) cannot be applied without modification due to the compact design of the PEM scanner, we decided to evaluate the NU 4 Standards as an alternative. We obtained the following results: Trans-axial spatial resolution 1.8 mm FWHM for high resolution reconstruction mode and 2.4 mm FWHM for standard resolution reconstruction mode with no significant variation within the field of view. The total system sensitivity was 0.16 cps/Bq. In image quality testing, the uniformity was found to be 3.9% STD at the standard resolution mode and 5.6% at the high resolution mode when measured with a 34 mm paddle separation. The NEMA NU 4-2008 Standards were found to be a practicable tool to evaluate the performance of the PEM scanner after some modifications to address the specifics of its detector configuration. Furthermore, the PEM scanner's in-plane spatial resolution was comparable to other small animal PET scanners with good image quality.

  12. Validation of Test Weighing Protocol to Estimate Enteral Feeding Volumes in Preterm Infants.

    PubMed

    Rankin, Michael W; Jimenez, Elizabeth Yakes; Caraco, Marina; Collinson, Marie; Lostetter, Lisa; DuPont, Tara L

    2016-11-01

    To evaluate the accuracy of pre- and postfeeding weights to estimate enteral feeding volumes in preterm infants. Single-center prospective cohort study of infants 28-36 weeks' corrected age receiving gavage feedings. For each test weight, 3 pre- and 3 postgavage feeding weights were obtained by study personnel, blinded to feeding volume, via a specific protocol. The correlation between test weight difference and actual volume ingested was assessed by the use of summary statistics, Spearman rho, and graphical analyses. The relationship between categorical predictive variables and a predefined acceptable difference (±5 mL) was assessed with the χ 2 or Fisher exact test. A total of 101 test weights were performed in 68 infants. Estimated and actual feeding volumes were highly correlated (r = 0.94, P < .001), with a mean absolute difference of 2.95 mL (SD: 2.70; range: 0, 12.3 mL; 5th, 95th percentile: 0, 9.3); 85% of test weights were within ±5 mL of actual feeding volume and did not vary significantly by corrected age, feeding tube or respiratory support type, feeding duration or volume, formula vs breast milk, or caloric density. With adherence to study protocol, 89% of test weights (66/74) were within ±5 mL of actual volume, compared with 71% (19/27, P = .04) when concerns about protocol adherence were noted (eg, difficulty securing oxygen tubing). Via the use of a standard protocol, feeding volumes can be estimated accurately by pre- and postfeeding weights. Test weighing could be a valuable tool to support direct breastfeeding in the neonatal intensive care unit. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. GCS programmer's manual

    NASA Technical Reports Server (NTRS)

    Lowman, Douglas S.; Withers, B. Edward; Shagnea, Anita M.; Dent, Leslie A.; Hayhurst, Kelly J.

    1990-01-01

    A variety of instructions to be used in the development of implementations of software for the Guidance and Control Software (GCS) project is described. This document fulfills the Radio Technical Commission for Aeronautics RTCA/DO-178A guidelines, 'Software Considerations in Airborne Systems and Equipment Certification' requirements for document No. 4, which specifies the information necessary for understanding and programming the host computer, and document No. 12, which specifies the software design and implementation standards that are applicable to the software development and testing process. Information on the following subjects is contained: activity recording, communication protocol, coding standards, change management, error handling, design standards, problem reporting, module testing logs, documentation formats, accuracy requirements, and programmer responsibilities.

  14. Field validation of protocols developed to evaluate in-line mastitis detection systems.

    PubMed

    Kamphuis, C; Dela Rue, B T; Eastwood, C R

    2016-02-01

    This paper reports on a field validation of previously developed protocols for evaluating the performance of in-line mastitis-detection systems. The protocols outlined 2 requirements of these systems: (1) to detect cows with clinical mastitis (CM) promptly and accurately to enable timely and appropriate treatment and (2) to identify cows with high somatic cell count (SCC) to manage bulk milk SCC levels. Gold standard measures, evaluation tests, performance measures, and performance targets were proposed. The current study validated the protocols on commercial dairy farms with automated in-line mastitis-detection systems using both electrical conductivity (EC) and SCC sensor systems that both monitor at whole-udder level. The protocol for requirement 1 was applied on 3 commercial farms. For requirement 2, the protocol was applied on 6 farms; 3 of them had low bulk milk SCC (128×10(3) cells/mL) and were the same farms as used for field evaluation of requirement 1. Three farms with high bulk milk SCC (270×10(3) cells/mL) were additionally enrolled. The field evaluation methodology and results were presented at a workshop including representation from 7 international suppliers of in-line mastitis-detection systems. Feedback was sought on the acceptance of standardized performance evaluation protocols and recommended refinements to the protocols. Although the methodology for requirement 1 was relatively labor intensive and required organizational skills over an extended period, no major issues were encountered during the field validation of both protocols. The validation, thus, proved the protocols to be practical. Also, no changes to the data collection process were recommended by the technology supplier representatives. However, 4 recommendations were made to refine the protocols: inclusion of an additional analysis that ignores small (low-density) clot observations in the definition of CM, extension of the time window from 4 to 5 milkings for timely alerts for CM, setting a maximum number of 10 milkings for the time window to detect a CM episode, and presentation of sensitivity for a larger range of false alerts per 1,000 milkings replacing minimum performance targets. The recommended refinements are discussed with suggested changes to the original protocols. The information presented is intended to inform further debate toward achieving international agreement on standard protocols to evaluate performance of in-line mastitis-detection systems. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  15. The Activity of Antimicrobial Surfaces Varies by Testing Protocol Utilized

    PubMed Central

    Campos, Matias D.; Zucchi, Paola C.; Phung, Ann; Leonard, Steven N.; Hirsch, Elizabeth B.

    2016-01-01

    Background Contaminated hospital surfaces are an important source of nosocomial infections. A major obstacle in marketing antimicrobial surfaces is a lack of efficacy data based on standardized testing protocols. Aim We compared the efficacy of multiple testing protocols against several “antimicrobial” film surfaces. Methods Four clinical isolates were used: one Escherichia coli, one Klebsiella pneumoniae, and two Staphylococcus aureus strains. Two industry methods (modified ISO 22196 and ASTM E2149), a “dried droplet”, and a “transfer” method were tested against two commercially available antimicrobial films, one film in development, an untreated control, and a positive (silver) control film. At 2 (only ISO) and 24 hours following inoculation, bacteria were collected from film surfaces and enumerated. Results Compared to untreated films in all protocols, there were no significant differences in recovery on either commercial brand at 2 or 24 hours after inoculation. The silver surface demonstrated significant microbicidal activity (mean loss 4.9 Log10 CFU/ml) in all methods and time points with the exception of 2 hours in the ISO protocol and the transfer method. Using our novel droplet method, no differences between placebo and active surfaces were detected. The surface in development demonstrated variable activity depending on method, organism, and time point. The ISO demonstrated minimal activity at 2 hours but significant activity at 24 hours (mean 4.5 Log10 CFU/ml difference versus placebo). The ASTEM protocol exhibited significant differences in recovery of staphylococci (mean 5 Log10 CFU/ml) but not Gram-negative isolates (10 fold decrease). Minimal activity was observed with this film in the transfer method. Conclusions Varying results between protocols suggested that efficacy of antimicrobial surfaces cannot be easily and reproducibly compared. Clinical use should be considered and further development of representative methods is needed. PMID:27494336

  16. Red light photodynamic therapy for actinic keratosis using 37 J/cm2 : Fractionated irradiation with 12.3 mW/cm2 after 30 minutes incubation time compared to standard continuous irradiation with 75 mW/cm2 after 3 hours incubation time using a mathematical modeling.

    PubMed

    Vignion-Dewalle, Anne-Sophie; Baert, Gregory; Devos, Laura; Thecua, Elise; Vicentini, Claire; Mortier, Laurent; Mordon, Serge

    2017-09-01

    Photodynamic therapy (PDT) is an emerging treatment modality for various diseases, especially for dermatological conditions. Although, the standard PDT protocol for the treatment of actinic keratoses in Europe has shown to be effective, treatment-associated pain is often observed in patients. Different modifications to this protocol attempted to decrease pain have been investigated. The decrease in fluence rate seems to be a promising solution. Moreover, it has been suggested that light fractionation significantly increases the efficacy of PDT. Based on a flexible light-emitting textile, the FLEXITHERALIGHT device specifically provides a fractionated illumination at a fluence rate more than six times lower than that of the standard protocol. In a recently completed clinical trial of PDT for the treatment of actinic keratosis, the non-inferiority of a protocol involving illumination with the FLEXITHERALIGHT device after a short incubation time and referred to as the FLEXITHERALIGHT protocol has been assessed compared to the standard protocol. In this paper, we propose a comparison of the two above mentioned 635 nm red light protocols with 37 J/cm 2 in the PDT treatment of actinic keratosis: the standard protocol and the FLEXITHERALIGHT one through a mathematical modeling. This mathematical modeling, which slightly differs from the one we have already published, enables the local damage induced by the therapy to be estimated. The comparison performed in terms of the local damage induced by the therapy demonstrates that the FLEXITHERALIGHT protocol with lower fluence rate, light fractionation and shorter incubation time is somewhat less efficient than the standard protocol. Nevertheless, from the clinical trial results, the FLEXITHERALIGHT protocol results in non-inferior response rates compared to the standard protocol. This finding raises the question of whether the PDT local damage achieved by the FLEXITHERALIGHT protocol (respectively, the standard protocol) is sufficient (respectively, excessive) to destroy actinic keratosis cells. Lasers Surg. Med. 49:686-697, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  17. Review: domestic animal forensic genetics - biological evidence, genetic markers, analytical approaches and challenges.

    PubMed

    Kanthaswamy, S

    2015-10-01

    This review highlights the importance of domestic animal genetic evidence sources, genetic testing, markers and analytical approaches as well as the challenges this field is facing in view of the de facto 'gold standard' human DNA identification. Because of the genetic similarity between humans and domestic animals, genetic analysis of domestic animal hair, saliva, urine, blood and other biological material has generated vital investigative leads that have been admitted into a variety of court proceedings, including criminal and civil litigation. Information on validated short tandem repeat, single nucleotide polymorphism and mitochondrial DNA markers and public access to genetic databases for forensic DNA analysis is becoming readily available. Although the fundamental aspects of animal forensic genetic testing may be reliable and acceptable, animal forensic testing still lacks the standardized testing protocols that human genetic profiling requires, probably because of the absence of monetary support from government agencies and the difficulty in promoting cooperation among competing laboratories. Moreover, there is a lack in consensus about how to best present the results and expert opinion to comply with court standards and bear judicial scrutiny. This has been the single most persistent challenge ever since the earliest use of domestic animal forensic genetic testing in a criminal case in the mid-1990s. Crime laboratory accreditation ensures that genetic test results have the courts' confidence. Because accreditation requires significant commitments of effort, time and resources, the vast majority of animal forensic genetic laboratories are not accredited nor are their analysts certified forensic examiners. The relevance of domestic animal forensic genetics in the criminal justice system is undeniable. However, further improvements are needed in a wide range of supporting resources, including standardized quality assurance and control protocols for sample handling, evidence testing, statistical analysis and reporting that meet the rules of scientific acceptance, reliability and human forensic identification standards. © 2015 Stichting International Foundation for Animal Genetics.

  18. Practical guidance for the implementation of stress echocardiography.

    PubMed

    Suzuki, Kengo; Hirano, Yutaka; Yamada, Hirotsugu; Murata, Mitsushige; Daimon, Masao; Takeuchi, Masaaki; Seo, Yoshihiro; Izumi, Chisato; Akaishi, Makoto

    2018-06-06

    Exercise stress testing has been widely undertaken for the diagnosis of heart diseases. The accurate assessment of clinical conditions can be conducted by comparing the findings obtained from the results of stress echocardiography with the changes in the blood/heart rate and electrocardiograms. Numerous overseas studies have reported the utility of stress echocardiography in diagnosing myocardial ischemia; in Japan, the use of this modality for this purpose was included in the national health insurance reimbursable list in 2012. Nevertheless, stress echocardiography is far from being a widespread practice in Japan. This might be due to insufficient equipment (e.g., ergometers, space for test implementation) at each medical institution, shortage of technicians and sonographers who are well experienced and who are responsible for obtaining images during stress testing. The other possible reasons include the limited evidence available in Japan and the lack of a standardized testing protocol. Further dissemination of the practice of exercise stress echocardiography in this country is deemed necessary to establish satisfactory evidence for the use of stress echocardiography in the Japanese population. To this end, efforts are underway to develop a standardized protocol and report format to be adopted throughout Japan. We here present a guideline created by the Guideline Development Committee of the Japanese Society of Echocardiography that describes safe and effective stress echocardiography protocols and report formats. The readers are encouraged to perform exercise stress echocardiography using the proposed template for consensus document and report attached to this guideline.

  19. Defense Logistics: DOD Has Addressed Most Reporting Requirements and Continues to Refine Its Asset Visibility Strategy

    DTIC Science & Technology

    2015-12-01

    Development, Test, and Evaluation RFID Radio Frequency Identification SEP Supporting Execution Plan Strategy Strategy to Improve Asset...migration of active Radio Frequency Identification ( RFID )19 from a proprietary communication standard protocol to an international standard to...technologies enabling hands-off processing of materiel deploying through the Defense Transportation System. Materiel marked with RFID tags may be remotely

  20. Pretreatment with low-energy shock waves induces renal vasoconstriction during standard SWL: a treatment protocol known to reduce lithotripsy-induced renal injury

    PubMed Central

    Handa, Rajash K.; Bailey, Michael R.; Paun, Marla; Gao, Sujuan; Connors, Bret A.; Willis, Lynn R.; Evan, Andrew P.

    2008-01-01

    Introduction and Objective A great deal of effort has been focused on developing new treatment protocols to reduce tissue injury to improve the safety of shock wave lithotripsy. This has led to the discovery that pretreatment of the kidney with a series of low-energy shock waves (SWs) will substantially reduce the hemorrhagic lesion that normally results from a standard clinical dose of high-energy SWs. Because renal blood flow is reduced following low- or high-energy SWL, and may therefore contribute to this effect, this study was designed to test the hypothesis that the pretreatment protocol induces renal vasoconstriction sooner than the standard protocol for SW delivery. Methods Female farm pigs (6-weeks old) were anesthetized with isoflurane and the lower pole of the right kidney treated with SWs using the HM3 lithotripter. Pulsed Doppler sonography was used to measure resistive index (RI) in blood vessels as a reflection of resistance/impedance to blood flow. RI was recorded from a single intralobar artery located in the targeted pole of the kidney, and measurements taken from pigs given sham SW treatment (Group 1; no SWs, n = 4), a standard clinical dose of high-energy SWs (Group 2; 2000 SWs, 24 kV, 120 SWs/min, n = 7), low-energy SW pretreatment followed by high-energy SWL (Group 3; 500 SWs, 12 kV, 120 SWs/min + 2000 SWs, 24 kV, 120 SWs/min, n = 8) and low-energy SW pretreatment alone (Group 4; 500 SWs, 12 kV, 120 SWs/min, n = 6). Results Baseline RI (~ 0.61) was similar for all groups. Pigs receiving sham SW treatment (Group 1) had no significant change in RI. A standard clinical dose of high-energy SWs (Group 2) did not significantly alter RI during treatment, but did increase RI at 45-min into the post-SWL period. Low-energy SWs did not alter RI in Group 3 pigs, but subsequent treatment with a standard clinical dose of high-energy SWs resulted in a significantly earlier (at 1000 SWs) and greater (two-fold) rise in RI than that observed in Group 2 pigs. This rise in RI during the low/high-energy SWL treatment protocol was not due to a delayed vasoconstrictor response of pretreatment, as low-energy SW treatment alone (Group 4) did not increase RI until 65 min into the post-SWL period. Conclusions The pretreatment protocol induces renal vasoconstriction during the period of SW application whereas the standard protocol shows vasoconstriction occurring only during the post-SWL period. Thus the earlier and greater rise in RI during the pretreatment protocol may be causally associated with a reduction in tissue injury. PMID:19154458

  1. A Modified Protocol for Color Vision Screening Using Ishihara.

    PubMed

    Chorley, Adrian C

    2015-08-01

    The Ishihara plates are commonly used as an initial occupational screening test for color vision. While effective at detecting red-green deficiencies, the color deficient subject can learn the test using different techniques. Some medical standards such as the European Aviation Safety Agency (EASA) require plate randomization and apply a stricter pass/fail requirement than suggested by Ishihara. This has been reported to increase the false positive rate up to ∼50%. Two modifications to the Ishihara protocol are investigated. These involved allowing subjects a second attempt where one or two reading errors were made and the presentation of rotated Ishihara plates. A reduction of false positive rate to 5.9% was found. Correct identification of certain rotated Ishihara plates was not affected. By using a modified Ishihara protocol, fewer color normal subjects would require unnecessary advanced color vision examination. Further, additional safeguards would be in place to ensure that no subject with a color vision deficiency could pass the Ishihara test.

  2. The Embryonic Stem Cell Test as Tool to Assess Structure-Dependent Teratogenicity: The Case of Valproic Acid

    PubMed Central

    Riebeling, Christian; Pirow, Ralph; Becker, Klaus; Buesen, Roland; Eikel, Daniel; Kaltenhäuser, Johanna; Meyer, Frauke; Nau, Heinz; Slawik, Birgitta; Visan, Anke; Volland, Jutta; Spielmann, Horst; Luch, Andreas; Seiler, Andrea

    2011-01-01

    Teratogenicity can be predicted in vitro using the embryonic stem cell test (EST). The EST, which is based on the morphometric measurement of cardiomyocyte differentiation and cytotoxicity parameters, represents a scientifically validated method for the detection and classification of chemicals according to their teratogenic potency. Furthermore, an abbreviated protocol applying flow cytometry of intracellular marker proteins to determine differentiation into the cardiomyocyte lineage is available. Although valproic acid (VPA) is in worldwide clinical use as antiepileptic drug, it exhibits two severe side effects, i.e., teratogenicity and hepatotoxicity. These limitations have led to extensive research into derivatives of VPA. Here we chose VPA as model compound to test the applicability domain and to further evaluate the reliability of the EST. To this end, we study six closely related congeners of VPA and demonstrate that both the standard and the molecular flow cytometry-based EST are well suited to indicate differences in the teratogenic potency among VPA analogs that differ only in chirality or side chain length. Our data show that identical results can be obtained by using the standard EST or a shortened protocol based on flow cytometry of intracellular marker proteins. Both in vitro protocols enable to reliably determine differentiation of murine stem cells toward the cardiomyocyte lineage and to assess its chemical-mediated inhibition. PMID:21227905

  3. Improving the accuracy of blood pressure measurement: the influence of the European Society of Hypertension International Protocol (ESH-IP) for the validation of blood pressure measuring devices and future perspectives.

    PubMed

    Stergiou, George S; Asmar, Roland; Myers, Martin; Palatini, Paolo; Parati, Gianfranco; Shennan, Andrew; Wang, Jiguang; O'Brien, Eoin

    2018-03-01

    The European Society of Hypertension (ESH) International Protocol (ESH-IP) for the validation of blood pressure (BP) measuring devices was published in 2002, with the main objective of simplifying the validation procedures, so that more BP monitors would be subjected to independent validation. This article provides an overview of the international impact of the ESH-IP and of the lessons learned from its use, to be able to justify further developments in validation protocols. A review of published (PubMed) validation studies from 2002 to 2017 was performed. One hundred and seventy-seven validation studies using the ESH-IP, 59 using the British Hypertension Society protocol, 46 using the Association for the Advancement of Medical Instrumentation (AAMI) standard and 23 using the International Organization for Standardization (ISO) standard were identified. Lists of validated office-clinic, home and ambulatory BP monitors are provided. Of the ESH-IP studies, 93% tested oscillometric devices, 80% upper arm, 71% home, 25% office and 7% ambulatory monitors (some had more than one function). The original goal of the ESH-IP has been fulfilled in that in the last decade the number of published validation studies has more than doubled. It is now recognized that the provision of accurate devices would be best served by having a universal protocol. An international initiative has been put in place by AAMI, ESH and ISO experts aiming to reach consensus for a universal validation protocol to be accepted worldwide, which will allow a more thorough evaluation of the accuracy and performance of future BP monitors.

  4. Cost-effectiveness of risk stratified followup after urethral reconstruction: a decision analysis.

    PubMed

    Belsante, Michael J; Zhao, Lee C; Hudak, Steven J; Lotan, Yair; Morey, Allen F

    2013-10-01

    We propose a novel risk stratified followup protocol for use after urethroplasty and explore potential cost savings. Decision analysis was performed comparing a symptom based, risk stratified protocol for patients undergoing excision and primary anastomosis urethroplasty vs a standard regimen of close followup for urethroplasty. Model assumptions included that excision and primary anastomosis has a 94% success rate, 11% of patients with successful urethroplasty had persistent lower urinary tract symptoms requiring cystoscopic evaluation, patients in whom treatment failed undergo urethrotomy and patients with recurrence on symptom based surveillance have a delayed diagnosis requiring suprapubic tube drainage. The Nationwide Inpatient Sample from 2010 was queried to identify the number of urethroplasties performed per year in the United States. Costs were obtained based on Medicare reimbursement rates. The 5-year cost of a symptom based, risk stratified followup protocol is $430 per patient vs $2,827 per patient using standard close followup practice. An estimated 7,761 urethroplasties were performed in the United States in 2010. Assuming that 60% were excision and primary anastomosis, and with more than 5 years of followup, the risk stratified protocol was projected to yield an estimated savings of $11,165,130. Sensitivity analysis showed that the symptom based, risk stratified followup protocol was far more cost-effective than standard close followup in all settings. Less than 1% of patients would be expected to have an asymptomatic recurrence using the risk stratified followup protocol. A risk stratified, symptom based approach to urethroplasty followup would produce a significant reduction in health care costs while decreasing unnecessary followup visits, invasive testing and radiation exposure. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  5. Colloidal Fouling of Nanofiltration Membranes: Development of a Standard Operating Procedure

    PubMed Central

    Al Mamun, Md Abdullaha; Bhattacharjee, Subir; Pernitsky, David; Sadrzadeh, Mohtada

    2017-01-01

    Fouling of nanofiltration (NF) membranes is the most significant obstacle to the development of a sustainable and energy-efficient NF process. Colloidal fouling and performance decline in NF processes is complex due to the combination of cake formation and salt concentration polarization effects, which are influenced by the properties of the colloids and the membrane, the operating conditions of the test, and the solution chemistry. Although numerous studies have been conducted to investigate the influence of these parameters on the performance of the NF process, the importance of membrane preconditioning (e.g., compaction and equilibrating with salt water), as well as the determination of key parameters (e.g., critical flux and trans-membrane osmotic pressure) before the fouling experiment have not been reported in detail. The aim of this paper is to present a standard experimental and data analysis protocol for NF colloidal fouling experiments. The developed methodology covers preparation and characterization of water samples and colloidal particles, pre-test membrane compaction and critical flux determination, measurement of experimental data during the fouling test, and the analysis of that data to determine the relative importance of various fouling mechanisms. The standard protocol is illustrated with data from a series of flat sheet, bench-scale experiments. PMID:28106775

  6. Comparison of eye lens dose on neuroimaging protocols between 16- and 64-section multidetector CT: achieving the lowest possible dose.

    PubMed

    Tan, J S P; Tan, K-L; Lee, J C L; Wan, C-M; Leong, J-L; Chan, L-L

    2009-02-01

    To our knowledge, there has been no study that compares the radiation dose delivered to the eye lens by 16- and 64-section multidetector CT (MDCT) for standard clinical neuroimaging protocols. Our aim was to assess radiation-dose differences between 16- and 64-section MDCT from the same manufacturer, by using near-identical neuroimaging protocols. Three cadaveric heads were scanned on 16- and 64-section MDCT by using standard neuroimaging CT protocols. Eye lens dose was measured by using thermoluminescent dosimeters (TLD), and each scanning was repeated to reduce random error. The dose-length product, volume CT dose index (CTDI(vol)), and TLD readings for each imaging protocol were averaged and compared between scanners and protocols, by using the paired Student t test. Statistical significance was defined at P < .05. The radiation dose delivered and eye lens doses were lower by 28.1%-45.7% (P < .000) on the 64-section MDCT for near-identical imaging protocols. On the 16-section MDCT, lens dose reduction was greatest (81.1%) on a tilted axial mode, compared with a nontilted helical mode for CT brain scans. Among the protocols studied, CT of the temporal bone delivered the greatest radiation dose to the eye lens. Eye lens radiation doses delivered by the 64-section MDCT are significantly lower, partly due to improvements in automatic tube current modulation technology. However, where applicable, protection of the eyes from the radiation beam by either repositioning the head or tilting the gantry remains the best way to reduce eye lens dose.

  7. Minimizing irreversible losses in quantum systems by local counterdiabatic driving

    PubMed Central

    Sels, Dries; Polkovnikov, Anatoli

    2017-01-01

    Counterdiabatic driving protocols have been proposed [Demirplak M, Rice SA (2003) J Chem Phys A 107:9937–9945; Berry M (2009) J Phys A Math Theor 42:365303] as a means to make fast changes in the Hamiltonian without exciting transitions. Such driving in principle allows one to realize arbitrarily fast annealing protocols or implement fast dissipationless driving, circumventing standard adiabatic limitations requiring infinitesimally slow rates. These ideas were tested and used both experimentally and theoretically in small systems, but in larger chaotic systems, it is known that exact counterdiabatic protocols do not exist. In this work, we develop a simple variational approach allowing one to find the best possible counterdiabatic protocols given physical constraints, like locality. These protocols are easy to derive and implement both experimentally and numerically. We show that, using these approximate protocols, one can drastically suppress heating and increase fidelity of quantum annealing protocols in complex many-particle systems. In the fast limit, these protocols provide an effective dual description of adiabatic dynamics, where the coupling constant plays the role of time and the counterdiabatic term plays the role of the Hamiltonian. PMID:28461472

  8. Assessment of oral storytelling abilities of Latino junior high school students with learning handicaps.

    PubMed

    Goldstein, B C; Harris, K C; Klein, M D

    1993-02-01

    This study investigated the relationship between reading comprehension and oral storytelling abilities. Thirty-one Latino junior high school students with learning handicaps were selected as subjects based on learning handicapped designation, home language, and language proficiency status. Reading comprehension was measured by the Reading Comprehension subtest of the Peabody Individual Achievement Test. Storytelling was measured by (a) the Oral Production subtest of the Language Assessment Scales using the standard scoring protocol and (b) a story structure analysis. A comparison of the standard scoring protocol and reading comprehension revealed no relationship, while the comparison of the story structure analysis and reading comprehension revealed a significant correlation. The implications of these results for language assessment of bilingual students are discussed.

  9. Biomechanical Comparison of Robotically Applied Pure Moment, Ideal Follower Load, and Novel Trunk Weight Loading Protocols on L4-L5 Cadaveric Segments during Flexion-Extension.

    PubMed

    Bennett, Charles R; DiAngelo, Denis J; Kelly, Brian P

    2015-01-01

    Extremely few in-vitro biomechanical studies have incorporated shear loads leaving a gap for investigation, especially when applied in combination with compression and bending under dynamic conditions. The objective of this study was to biomechanically compare sagittal plane application of two standard protocols, pure moment (PM) and follower load (FL), with a novel trunk weight (TW) loading protocol designed to induce shear in combination with compression and dynamic bending in a neutrally potted human cadaveric L4-L5 motion segment unit (MSU) model. A secondary objective and novelty of the current study was the application of all three protocols within the same testing system serving to reduce artifacts due to testing system variability. Six L4-L5 segments were tested in a Cartesian load controlled system in flexion-extension to 8Nm under PM, simulated ideal 400N FL, and vertically oriented 400N TW loading protocols. Comparison metrics used were rotational range of motion (RROM), flexibility, neutral zone (NZ) range of motion, and L4 vertebral body displacements. Significant differences in vertebral body translations were observed with different initial force applications but not with subsequent bending moment application. Significant reductions were observed in combined flexion-extension RROM, in flexibility during extension, and in NZ region flexibility with the TW loading protocol as compared to PM loading. Neutral zone ranges of motion were not different between all protocols. The combined compression and shear forces applied across the spinal joint in the trunk weight protocol may have a small but significantly increased stabilizing effect on segment flexibility and kinematics during sagittal plane flexion and extension.

  10. Biomechanical Comparison of Robotically Applied Pure Moment, Ideal Follower Load, and Novel Trunk Weight Loading Protocols on L4-L5 Cadaveric Segments during Flexion-Extension

    PubMed Central

    Bennett, Charles R.; DiAngelo, Denis J.

    2015-01-01

    Background Extremely few in-vitro biomechanical studies have incorporated shear loads leaving a gap for investigation, especially when applied in combination with compression and bending under dynamic conditions. The objective of this study was to biomechanically compare sagittal plane application of two standard protocols, pure moment (PM) and follower load (FL), with a novel trunk weight (TW) loading protocol designed to induce shear in combination with compression and dynamic bending in a neutrally potted human cadaveric L4-L5 motion segment unit (MSU) model. A secondary objective and novelty of the current study was the application of all three protocols within the same testing system serving to reduce artifacts due to testing system variability. Methods Six L4-L5 segments were tested in a Cartesian load controlled system in flexion-extension to 8Nm under PM, simulated ideal 400N FL, and vertically oriented 400N TW loading protocols. Comparison metrics used were rotational range of motion (RROM), flexibility, neutral zone (NZ) range of motion, and L4 vertebral body displacements. Results Significant differences in vertebral body translations were observed with different initial force applications but not with subsequent bending moment application. Significant reductions were observed in combined flexion-extension RROM, in flexibility during extension, and in NZ region flexibility with the TW loading protocol as compared to PM loading. Neutral zone ranges of motion were not different between all protocols. Conclusions The combined compression and shear forces applied across the spinal joint in the trunk weight protocol may have a small but significantly increased stabilizing effect on segment flexibility and kinematics during sagittal plane flexion and extension. PMID:26273551

  11. Internet Access to Spacecraft

    NASA Technical Reports Server (NTRS)

    Rash, James; Parise, Ron; Hogie, Keith; Criscuolo, Ed; Langston, Jim; Jackson, Chris; Price, Harold; Powers, Edward I. (Technical Monitor)

    2000-01-01

    The Operating Missions as Nodes on the Internet (OMNI) project at NASA's Goddard Space flight Center (GSFC), is demonstrating the use of standard Internet protocols for spacecraft communication systems. This year, demonstrations of Internet access to a flying spacecraft have been performed with the UoSAT-12 spacecraft owned and operated by Surrey Satellite Technology Ltd. (SSTL). Previously, demonstrations were performed using a ground satellite simulator and NASA's Tracking and Data Relay Satellite System (TDRSS). These activities are part of NASA's Space Operations Management Office (SOMO) Technology Program, The work is focused on defining the communication architecture for future NASA missions to support both NASA's "faster, better, cheaper" concept and to enable new types of collaborative science. The use of standard Internet communication technology for spacecraft simplifies design, supports initial integration and test across an IP based network, and enables direct communication between scientists and instruments as well as between different spacecraft, The most recent demonstrations consisted of uploading an Internet Protocol (IP) software stack to the UoSAT- 12 spacecraft, simple modifications to the SSTL ground station, and a series of tests to measure performance of various Internet applications. The spacecraft was reconfigured on orbit at very low cost. The total period between concept and the first tests was only 3 months. The tests included basic network connectivity (PING), automated clock synchronization (NTP), and reliable file transfers (FTP). Future tests are planned to include additional protocols such as Mobile IP, e-mail, and virtual private networks (VPN) to enable automated, operational spacecraft communication networks. The work performed and results of the initial phase of tests are summarized in this paper. This work is funded and directed by NASA/GSFC with technical leadership by CSC in arrangement with SSTL, and Vytek Wireless.

  12. Process and Outcome of Fecal Microbiota Transplants in Patients With Recurrent Clostridium difficile Infection: A Prospective Study.

    PubMed

    Walton, Janice; Burns, Denise; Gaehle, Kay E

    The incidence of Clostridium difficile infection is on the rise worldwide, causing high mortality rates and costing patients, hospitals, and insurance companies millions of dollars annually. Fecal microbiota transplants successfully treat recurrent C. difficile infections unresponsive to standard pharmacologic treatment such as flagyl, vancomycin, or rifaximin. Evidence in the literature provided the foundation for the development and refinement of this fecal microbiota transplant protocol. During the initial phase of the project, the protocol included patient selection criteria, donor screening/selection, infection control, fecal processing and delivery, and patient pre and postprocedure education. This article highlights the second phase of prospective testing of a nurse-driven protocol to implement fecal microbiota transplantation in patients with recurrent C. difficile infection. All stages of the protocol are explained as well as rationale for component parts to achieve successful patient outcomes when the protocol is carefully followed.

  13. 42 CFR 493.1278 - Standard: Histocompatibility.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... organ and tissue transplants; (ii) Testing protocols for patients at high risk for allograft rejection... each type of cell, tissue or organ to be transfused or transplanted. The laboratory's policies must... or allele level). (2) For renal allotransplantation and combined organ and tissue transplants in...

  14. 42 CFR 493.1278 - Standard: Histocompatibility.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... organ and tissue transplants; (ii) Testing protocols for patients at high risk for allograft rejection... each type of cell, tissue or organ to be transfused or transplanted. The laboratory's policies must... or allele level). (2) For renal allotransplantation and combined organ and tissue transplants in...

  15. 42 CFR 493.1278 - Standard: Histocompatibility.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... organ and tissue transplants; (ii) Testing protocols for patients at high risk for allograft rejection... each type of cell, tissue or organ to be transfused or transplanted. The laboratory's policies must... or allele level). (2) For renal allotransplantation and combined organ and tissue transplants in...

  16. RELIABILITY OF CONFOCAL MICROSCOPY SPECTRAL IMAGING SYSTEMS: USE OF MULTISPECTRAL BEADS

    EPA Science Inventory

    Background: There is a need for a standardized, impartial calibration, and validation protocol on confocal spectral imaging (CSI) microscope systems. To achieve this goal, it is necessary to have testing tools to provide a reproducible way to evaluate instrument performance. ...

  17. Time-domain diffuse optics using bioresorbable fibers: a proof-of-principle study

    NASA Astrophysics Data System (ADS)

    Di Sieno, Laura; Boetti, Nadia G.; Dalla Mora, Alberto; Pugliese, Diego; Farina, Andrea; Konugolu Venkata Sekar, Sanathana; Ceci-Ginistrelli, Edoardo; Janner, Davide; Pifferi, Antonio; Milanese, Daniel

    2017-07-01

    We show for the first time the aptness of Calcium Phosphate Glass-based bioresorbable fibers for time-domain diffuse optics using tests described by a standardized protocol and we also present a spectroscopic measurement on a chicken breast.

  18. Evaluation of a Modified Pamidronate Protocol for the Treatment of Osteogenesis Imperfecta.

    PubMed

    Palomo, Telma; Andrade, Maria C; Peters, Barbara S E; Reis, Fernanda A; Carvalhaes, João Tomás A; Glorieux, Francis H; Rauch, Frank; Lazaretti-Castro, Marise

    2016-01-01

    Intravenous pamidronate is widely used to treat children with osteogenesis imperfecta (OI). In a well-studied protocol ('standard protocol'), pamidronate is given at a daily dose of 1 mg per kg body weight over 4 h on 3 successive days; infusion cycles are repeated every 4 months. Here, we evaluated renal safety of a simpler protocol for intravenous pamidronate infusions (2 mg per kg body weight given in a single infusion over 2 h, repeated every 4 months; 'modified protocol'). Results of 18 patients with OI types I, III, or IV treated with the modified protocol for 12 months were compared to 18 historic controls, treated with standard protocol. In the modified protocol, mild transient post-infusion increases in serum creatinine were found during each infusion but after 12 months serum creatinine remained similar from baseline [0.40 mg/dl (SD: 0.13)] to the end of the study [0.41 mg/dl (SD: 0.11)] (P = 0.79). The two protocols led to similar changes in serum creatinine during the first pamidronate infusion [modified protocol: +2% (SD: 21%); standard protocol: -3% (SD: 8%); P = 0.32]. Areal lumbar spine bone mineral density Z-scores increased from -2.7 (SD: 1.5) to -1.8 (SD: 1.4) with the modified protocol, and from -4.1 (SD: 1.4) to -3.1 (SD: 1.1) with standard protocol (P = 0.68 for group differences in bone density Z-score changes). The modified pamidronate protocol is safe and may have similar effects on bone density as the standard pamidronate protocol. More studies are needed with longer follow-up to prove anti-fracture efficacy.

  19. A formal protocol test procedure for the Survivable Adaptable Fiber Optic Embedded Network (SAFENET)

    NASA Astrophysics Data System (ADS)

    High, Wayne

    1993-03-01

    This thesis focuses upon a new method for verifying the correct operation of a complex, high speed fiber optic communication network. These networks are of growing importance to the military because of their increased connectivity, survivability, and reconfigurability. With the introduction and increased dependence on sophisticated software and protocols, it is essential that their operation be correct. Because of the speed and complexity of fiber optic networks being designed today, they are becoming increasingly difficult to test. Previously, testing was accomplished by application of conformance test methods which had little connection with an implementation's specification. The major goal of conformance testing is to ensure that the implementation of a profile is consistent with its specification. Formal specification is needed to ensure that the implementation performs its intended operations while exhibiting desirable behaviors. The new conformance test method presented is based upon the System of Communicating Machine model which uses a formal protocol specification to generate a test sequence. The major contribution of this thesis is the application of the System of Communicating Machine model to formal profile specifications of the Survivable Adaptable Fiber Optic Embedded Network (SAFENET) standard which results in the derivation of test sequences for a SAFENET profile. The results applying this new method to SAFENET's OSI and Lightweight profiles are presented.

  20. Method and platform standardization in MRM-based quantitative plasma proteomics.

    PubMed

    Percy, Andrew J; Chambers, Andrew G; Yang, Juncong; Jackson, Angela M; Domanski, Dominik; Burkhart, Julia; Sickmann, Albert; Borchers, Christoph H

    2013-12-16

    There exists a growing demand in the proteomics community to standardize experimental methods and liquid chromatography-mass spectrometry (LC/MS) platforms in order to enable the acquisition of more precise and accurate quantitative data. This necessity is heightened by the evolving trend of verifying and validating candidate disease biomarkers in complex biofluids, such as blood plasma, through targeted multiple reaction monitoring (MRM)-based approaches with stable isotope-labeled standards (SIS). Considering the lack of performance standards for quantitative plasma proteomics, we previously developed two reference kits to evaluate the MRM with SIS peptide approach using undepleted and non-enriched human plasma. The first kit tests the effectiveness of the LC/MRM-MS platform (kit #1), while the second evaluates the performance of an entire analytical workflow (kit #2). Here, these kits have been refined for practical use and then evaluated through intra- and inter-laboratory testing on 6 common LC/MS platforms. For an identical panel of 22 plasma proteins, similar concentrations were determined, regardless of the kit, instrument platform, and laboratory of analysis. These results demonstrate the value of the kit and reinforce the utility of standardized methods and protocols. The proteomics community needs standardized experimental protocols and quality control methods in order to improve the reproducibility of MS-based quantitative data. This need is heightened by the evolving trend for MRM-based validation of proposed disease biomarkers in complex biofluids such as blood plasma. We have developed two kits to assist in the inter- and intra-laboratory quality control of MRM experiments: the first kit tests the effectiveness of the LC/MRM-MS platform (kit #1), while the second evaluates the performance of an entire analytical workflow (kit #2). In this paper, we report the use of these kits in intra- and inter-laboratory testing on 6 common LC/MS platforms. This article is part of a Special Issue entitled: Standardization and Quality Control in Proteomics. © 2013.

  1. Advanced Combat Helmet Technical Assessment

    DTIC Science & Technology

    2013-05-29

    Lastly, we assessed the participation of various stakeholders and industry experts such as active ACH manufacturers and test facilities. Findings... industrially accepted American National Standards Institute (ANSI Z1.4-2008, Sampling Visit us on the web at www.dodig.mil Results in Brief Advanced...statistically principled approach and the lot acceptance test protocol adopts a widely established and industrially accepted sampling procedure. We

  2. Measurement of pulmonary arterial impedance and reflection from single-slice phase-contrast and steady-state free precession MRI

    NASA Astrophysics Data System (ADS)

    Leimbigler, Peter John

    Pulmonary arterial hypertension (PAH) alters vessel wall mechanics and vasomotor tone, driving up pulmonary hemodynamic variables such as pulse wave velocity, input and characteristic impedance, and pulse wave reflection magnitude. Heterogeneous treatment response necessitates frequent hemodynamic evaluation, for which right-heart catheterization (RHC) remains the gold standard; however, several disadvantages limit its frequency of use. In this work, a non-invasive magnetic resonance (MR) imaging protocol is developed to address the shortcomings of invasive hemodynamic monitoring and may support existing diagnostic procedures. First, accuracy and precision of the proposed method is characterized through linear uncertainty propagation and numerical simulation of the data-processing pipeline. Second, the MR protocol is tested in seven healthy adult volunteers. Third, a rapid version of the MR protocol is tested in a healthy volunteer, yielding good agreement with mean values obtained in the seven-volunteer study.

  3. New understandings of failure modes in SSL luminaires

    NASA Astrophysics Data System (ADS)

    Shepherd, Sarah D.; Mills, Karmann C.; Yaga, Robert; Johnson, Cortina; Davis, J. Lynn

    2014-09-01

    As SSL products are being rapidly introduced into the market, there is a need to develop standard screening and testing protocols that can be performed quickly and provide data surrounding product lifetime and performance. These protocols, derived from standard industry tests, are known as ALTs (accelerated life tests) and can be performed in a timeframe of weeks to months instead of years. Accelerated testing utilizes a combination of elevated temperature and humidity conditions as well as electrical power cycling to control aging of the luminaires. In this study, we report on the findings of failure modes for two different luminaire products exposed to temperature-humidity ALTs. LEDs are typically considered the determining component for the rate of lumen depreciation. However, this study has shown that each luminaire component can independently or jointly influence system performance and reliability. Material choices, luminaire designs, and driver designs all have significant impacts on the system reliability of a product. From recent data, it is evident that the most common failure modes are not within the LED, but instead occur within resistors, capacitors, and other electrical components of the driver. Insights into failure modes and rates as a result of ALTs are reported with emphasis on component influence on overall system reliability.

  4. Improved ASTM G72 Test Method for Ensuring Adequate Fuel-to-Oxidizer Ratios

    NASA Technical Reports Server (NTRS)

    Juarez, Alfredo; Harper, Susana A.

    2016-01-01

    The ASTM G72/G72M-15 Standard Test Method for Autogenous Ignition Temperature of Liquids and Solids in a High-Pressure Oxygen-Enriched Environment is currently used to evaluate materials for the ignition susceptibility driven by exposure to external heat in an enriched oxygen environment. Testing performed on highly volatile liquids such as cleaning solvents has proven problematic due to inconsistent test results (non-ignitions). Non-ignition results can be misinterpreted as favorable oxygen compatibility, although they are more likely associated with inadequate fuel-to-oxidizer ratios. Forced evaporation during purging and inadequate sample size were identified as two potential causes for inadequate available sample material during testing. In an effort to maintain adequate fuel-to-oxidizer ratios within the reaction vessel during test, several parameters were considered, including sample size, pretest sample chilling, pretest purging, and test pressure. Tests on a variety of solvents exhibiting a range of volatilities are presented in this paper. A proposed improvement to the standard test protocol as a result of this evaluation is also presented. Execution of the final proposed improved test protocol outlines an incremental step method of determining optimal conditions using increased sample sizes while considering test system safety limits. The proposed improved test method increases confidence in results obtained by utilizing the ASTM G72 autogenous ignition temperature test method and can aid in the oxygen compatibility assessment of highly volatile liquids and other conditions that may lead to false non-ignition results.

  5. Development of Standardized Material Testing Protocols for Prosthetic Liners

    PubMed Central

    Cagle, John C.; Reinhall, Per G.; Hafner, Brian J.; Sanders, Joan E.

    2017-01-01

    A set of protocols was created to characterize prosthetic liners across six clinically relevant material properties. Properties included compressive elasticity, shear elasticity, tensile elasticity, volumetric elasticity, coefficient of friction (CoF), and thermal conductivity. Eighteen prosthetic liners representing the diverse range of commercial products were evaluated to create test procedures that maximized repeatability, minimized error, and provided clinically meaningful results. Shear and tensile elasticity test designs were augmented with finite element analysis (FEA) to optimize specimen geometries. Results showed that because of the wide range of available liner products, the compressive elasticity and tensile elasticity tests required two test maxima; samples were tested until they met either a strain-based or a stress-based maximum, whichever was reached first. The shear and tensile elasticity tests required that no cyclic conditioning be conducted because of limited endurance of the mounting adhesive with some liner materials. The coefficient of friction test was based on dynamic coefficient of friction, as it proved to be a more reliable measurement than static coefficient of friction. The volumetric elasticity test required that air be released beneath samples in the test chamber before testing. The thermal conductivity test best reflected the clinical environment when thermal grease was omitted and when liner samples were placed under pressure consistent with load bearing conditions. The developed procedures provide a standardized approach for evaluating liner products in the prosthetics industry. Test results can be used to improve clinical selection of liners for individual patients and guide development of new liner products. PMID:28233885

  6. Sizing Single Cantilever Beam Specimens for Characterizing Facesheet/Core Peel Debonding in Sandwich Structure

    NASA Technical Reports Server (NTRS)

    Ratcliffe, James G.

    2010-01-01

    This paper details part of an effort focused on the development of a standardized facesheet/core peel debonding test procedure. The purpose of the test is to characterize facesheet/core peel in sandwich structure, accomplished through the measurement of the critical strain energy release rate associated with the debonding process. The specific test method selected for the standardized test procedure utilizes a single cantilever beam (SCB) specimen configuration. The objective of the current work is to develop a method for establishing SCB specimen dimensions. This is achieved by imposing specific limitations on specimen dimensions, with the objectives of promoting a linear elastic specimen response, and simplifying the data reduction method required for computing the critical strain energy release rate associated with debonding. The sizing method is also designed to be suitable for incorporation into a standardized test protocol. Preliminary application of the resulting sizing method yields practical specimen dimensions.

  7. A review of mammalian carcinogenicity study design and potential effects of alternate test procedures on the safety evaluation of food ingredients.

    PubMed

    Hayes, A W; Dayan, A D; Hall, W C; Kodell, R L; Williams, G M; Waddell, W D; Slesinski, R S; Kruger, C L

    2011-06-01

    Extensive experience in conducting long term cancer bioassays has been gained over the past 50 years of animal testing on drugs, pesticides, industrial chemicals, food additives and consumer products. Testing protocols for the conduct of carcinogenicity studies in rodents have been developed in Guidelines promulgated by regulatory agencies, including the US EPA (Environmental Protection Agency), the US FDA (Food and Drug Administration), the OECD (Organization for Economic Co-operation and Development) for the EU member states and the MAFF (Ministries of Agriculture, Forestries and Fisheries) and MHW (Ministry of Health and Welfare) in Japan. The basis of critical elements of the study design that lead to an accepted identification of the carcinogenic hazard of substances in food and beverages is the focus of this review. The approaches used by entities well-known for carcinogenicity testing and/or guideline development are discussed. Particular focus is placed on comparison of testing programs used by the US National Toxicology Program (NTP) and advocated in OECD guidelines to the testing programs of the European Ramazzini Foundation (ERF), an organization with numerous published carcinogenicity studies. This focus allows for a good comparison of differences in approaches to carcinogenicity testing and allows for a critical consideration of elements important to appropriate carcinogenicity study designs and practices. OECD protocols serve as good standard models for carcinogenicity testing protocol design. Additionally, the detailed design of any protocol should include attention to the rationale for inclusion of particular elements, including the impact of those elements on study interpretations. Appropriate interpretation of study results is dependent on rigorous evaluation of the study design and conduct, including differences from standard practices. Important considerations are differences in the strain of animal used, diet and housing practices, rigorousness of test procedures, dose selection, histopathology procedures, application of historical control data, statistical evaluations and whether statistical extrapolations are supported by, or are beyond the limits of, the data generated. Without due consideration, there can be result conflicting data interpretations and uncertainty about the relevance of a study's results to human risk. This paper discusses the critical elements of rodent (rat) carcinogenicity studies, particularly with respect to the study of food ingredients. It also highlights study practices and procedures that can detract from the appropriate evaluation of human relevance of results, indicating the importance of adherence to international consensus protocols, such as those detailed by OECD. Copyright © 2010. Published by Elsevier Inc.

  8. Head Tilt Posturography to Enhance Balance Control Assessment for Astronauts: A Case Study

    NASA Technical Reports Server (NTRS)

    Hwang, E. Y.; Paloski, W. H.

    2006-01-01

    For many years, we have used a standard clinical computerized dynamic posturography (CDP) protocol to assess recovery of integrated sensory-motor function in astronauts returning from space flight. The most reliable indications of postflight crew performance capabilities have been obtained from the sensory organization tests (SOTs) within the CDP protocol, particularly SOTs 5 (eyes closed, surface support sway referenced) and 6 (eyes open, surface support and visual surround sway referenced), which are sensitive to changes in availability and/or utilization of vestibular cues. We have observed, however, that some astronauts exhibiting visible signs of incomplete sensory-motor recovery are able to score within clinical norms on standard SOTs 5 and 6 trials, perhaps as a result of cognitive strategies driven by their naturally competitive natures. To improve the sensitivity of the CDP protocol for assessing recovery of integrated sensory-motor function and fitness to return to duties and/or activities of daily living, we have introduced pitch plane head tilt SOT trials to our protocol. In a preliminary study of 5 short duration (11day missions) astronauts, we showed that they were unable to maintain balance on landing day when performing dynamic head tilt trials, despite scoring within the clinically normal range on the standard SOT trials. The present case report illustrates the advantages of including head tilt trials for assessing sensory-motor recovery in long duration crewmembers.

  9. Development and Pilot-Testing of a Cognitive Behavioral Coping Skills Group Intervention for Patients with Chronic Hepatitis C.

    PubMed

    Evon, Donna M; Golin, Carol E; Ruffin, Rachel; Fried, Michael W

    2017-06-01

    Psychosocial interventions for patients with chronic hepatitis C viral (HCV) infection are needed to attenuate the impact of extrahepatic symptoms, comorbid conditions, and treatment side effects on HCV health outcomes. We adapted empirically-supported interventions for similar patient populations to develop a Cognitive Behavioral Coping Skills group intervention for HCV patients (CBCS-HCV) undergoing treatment. The objectives of this paper are to describe the research activities associated with CBCS-HCV development and pilot testing, including: (1) formative work leading to intervention development; (2) preliminary study protocol; and (3) pilot feasibility testing of the intervention and study design. Formative work included a literature review, qualitative interviews, and adaption, development, and review of study materials. A preliminary study protocol is described. We evaluate the feasibility of conducting a randomized controlled trial (RCT) of the CBCS-HCV with 12 study participants in Wave 1 testing to examine: (a) feasibility of intervention delivery; (b) patient acceptability; (c) recruitment, enrollment, retention; (d) feasibility of conducting a RCT; (d) therapist protocol fidelity; and (e) feasibility of data collection. Numerous lessons were learned. We found very high rates of data collection, participant attendance, engagement, retention and acceptability, and therapist protocol fidelity. We conclude that many aspects of the CBCS-HCV intervention and study protocol were highly feasible. The greatest challenge during this Wave 1 pilot study was efficiency of participant enrollment due to changes in standard of care treatment. These findings informed two additional waves of pilot testing to examine effect sizes and potential improvements in clinical outcomes, with results forthcoming.

  10. Validity of an Exercise Test Based on Habitual Gait Speed in Mobility-Limited Older Adults

    PubMed Central

    Li, Xin; Forman, Daniel E.; Kiely, Dan K.; LaRose, Sharon; Hirschberg, Ronald; Frontera, Walter R.; Bean, Jonathan F.

    2013-01-01

    Objective To evaluate whether a customized exercise tolerance testing (ETT) protocol based on an individual’s habitual gait speed (HGS) on level ground would be a valid mode of exercise testing older adults. Although ETT provides a useful means to risk-stratify adults, age-related declines in gait speed paradoxically limit the utility of standard ETT protocols for evaluating older adults. A customized ETT protocol may be a useful alternative to these standard methods, and this study hypothesized that this alternative approach would be valid. Design We performed a cross-sectional analysis of baseline data from a randomized controlled trial of older adults with observed mobility problems. Screening was performed using a treadmill-based ETT protocol customized for each individual’s HGS. We determined the content validity by assessing the results of the ETTs, and we evaluated the construct validity of treadmill time in relation to the Physical Activity Scale for the Elderly (PASE) and the Late Life Function and Disability Instrument (LLFDI). Setting Outpatient rehabilitation center. Participants Community-dwelling, mobility-limited older adults (N = 141). Interventions Not applicable. Main Outcome Measures Cardiac instability, ETT duration, peak heart rate, peak systolic blood pressure, PASE, and LLFDI. Results Acute cardiac instability was identified in 4 of the participants who underwent ETT. The remaining participants (n = 137, 68% female; mean age, 75.3y) were included in the subsequent analyses. Mean exercise duration was 9.39 minutes, with no significant differences in durations being observed after evaluating among tertiles by HGS status. Mean peak heart rate and mean peak systolic blood pressure were 126.6 beats/ min and 175.0mmHg, respectively. Within separate multivariate models, ETT duration in each of the 3 gait speed groups was significantly associated (P<.05) with PASE and LLFDI. Conclusions Mobility-limited older adults can complete this customized ETT protocol, allowing for the identification of acute cardiac instability and the achievement of optimal exercise parameters. PMID:22289248

  11. DDN (Defense Data Network) Protocol Handbook. Volume 1. DoD Military Standard Protocols

    DTIC Science & Technology

    1985-12-01

    official Military Standard communication protocols in use on the DDN are included, as are several ARPANET (Advanced Research Projects Agency Network... research protocols which are currently in use, and some protocols currently undergoing review. Tutorial information and auxiliary documents are also...compatible with DoD needs, by researchers wishing to improve the protocols, and by impleroentors of local area networks (LANs) wishing their

  12. Surgical hand preparation with chlorhexidine soap or povidone iodine: new methods to increase immediate and residual effectiveness, and provide a safe alternative to alcohol solutions.

    PubMed

    Herruzo, R; Vizcaino, M J; Yela, R

    2018-04-01

    Surgical use of 4% chlorhexidine soap (CHX-4) and 10% povidone iodine (PVP-I-10) does not meet the standards defined by EN 12791. To investigate the possibility of increasing the immediate and residual effects of these antiseptics. Over three consecutive weeks, n-propanol, standard CHX-4 and PVP-I-10 were tested in two experimental groups of volunteers. The new method for applying the antiseptic substances involved standard hand rub and rinse of CHX-4 or PVP-I-10, followed by application of an aqueous solution based on 5% chlorhexidine or PVP-I-10 with no further rinsing of the hands prior to donning gloves. Samples were taken to assess immediate and residual effects, analysing the logarithmic reduction of colony-forming units. At t=0 h, n-propanol was superior in bactericidal effect to standard CHX-4 (P<0.05), but the new chlorhexidine protocol was superior to both standard CHX-4 (P<0.01) and n-propanol (P<0.05); the same effect was observed at t=3 h (residual effect). At t=0 h, n-propanol was significantly superior to standard PVP-I-10, but the new PVP-I-10 protocol was superior, although not significantly, to n-propanol. There was no significant residual effect at t=3 h. The new protocol for chlorhexidine application permits surgical hand preparation with chlorhexidine, as a safe alternative to alcohol solutions, because it meets the standards defined by EN 12791. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  13. Bedside Diagnosis of Dysphagia: A Systematic Review

    PubMed Central

    O’Horo, John C.; Rogus-Pulia, Nicole; Garcia-Arguello, Lisbeth; Robbins, JoAnne; Safdar, Nasia

    2015-01-01

    Background Dysphagia is associated with aspiration, pneumonia and malnutrition, but remains challenging to identify at the bedside. A variety of exam protocols and maneuvers are commonly used, but the efficacy of these maneuvers is highly variable. Methods We conducted a comprehensive search of seven databases, including MEDLINE, EMBASE and Scopus, from each database’s earliest inception through June 5th, 2013. Studies reporting diagnostic performance of a bedside examination maneuver compared to a reference gold standard (videofluoroscopic swallow study [VFSS] or flexible endoscopic evaluation of swallowing with sensory testing [FEEST]) were included for analysis. From each study, data were abstracted based on the type of diagnostic method and reference standard study population and inclusion/exclusion characteristics, design and prediction of aspiration. Results The search strategy identified 38 articles meeting inclusion criteria. Overall, most bedside examinations lacked sufficient sensitivity to be used for screening purposes across all patient populations examined. Individual studies found dysphonia assessments, abnormal pharyngeal sensation assessments, dual axis accelerometry, and one description of water swallow testing to be sensitive tools, but none were reported as consistently sensitive. A preponderance of identified studies was in post-stroke adults, limiting the generalizability of results. Conclusions No bedside screening protocol has been shown to provide adequate predictive value for presence of aspiration. Several individual exam maneuvers demonstrated reasonable sensitivity, but reproducibility and consistency of these protocols was not established. More research is needed to design an optimal protocol for dysphagia detection. PMID:25581840

  14. Auditory fitness for duty: a review.

    PubMed

    Tufts, Jennifer B; Vasil, Kristin A; Briggs, Sarah

    2009-10-01

    Auditory fitness for duty (AFFD) refers to the possession of hearing abilities sufficient for safe and effective job performance. In jobs such as law enforcement and piloting, where the ability to hear is critical to job performance and safety, hearing loss can decrease performance, even to the point of being hazardous to self and others. Tests of AFFD should provide an employer with a valid assessment of an employee's ability to perform the job safely, without discriminating against the employee purely on the basis of hearing loss. The purpose of this review is to provide a basic description of the functional hearing abilities required in hearing-critical occupations, and a summary of current practices in AFFD evaluation. In addition, we suggest directions for research and standardization to ensure best practices in the evaluation of AFFD in the future. We conducted a systematic review of the English-language peer-reviewed literature in AFFD. "Popular" search engines were consulted for governmental regulations and trade journal articles. We also contacted professionals with expertise in AFFD regarding research projects, unpublished material, and current standards. The literature review provided information regarding the functional hearing abilities required to perform hearing-critical tasks, the development of and characteristics of AFFD protocols, and the current implementation of AFFD protocols. This review paper provides evidence of the need to institute job-specific AFFD protocols, move beyond the pure-tone audiogram, and establish the validity of test protocols. These needs are arguably greater now than in times past.

  15. Broth Microdilution In Vitro Screening: An Easy and Fast Method to Detect New Antifungal Compounds.

    PubMed

    de-Souza-Silva, Calliandra Maria; Guilhelmelli, Fernanda; Zamith-Miranda, Daniel; de Oliveira, Marco Antônio; Nosanchuk, Joshua Daniel; Silva-Pereira, Ildinete; Albuquerque, Patrícia

    2018-02-14

    Fungal infections have become an important medical condition in the last decades, but the number of available antifungal drugs is limited. In this scenario, the search for new antifungal drugs is necessary. The protocol reported here details a method to screen peptides for their antifungal properties. It is based on the broth microdilution susceptibility test from the Clinical and Laboratory Standards Institute (CLSI) M27-A3 guidelines with modifications to suit the research of antimicrobial peptides as potential new antifungals. This protocol describes a functional assay to evaluate the activity of antifungal compounds and may be easily modified to suit any particular class of molecules under investigation. Since the assays are performed in 96-well plates using small volumes, a large-scale screening can be completed in a short amount of time, especially if carried out in an automation setting. This procedure illustrates how a standardized and adjustable clinical protocol can help the bench-work pursuit of new molecules to improve the therapy of fungal diseases.

  16. DNA origami-based standards for quantitative fluorescence microscopy.

    PubMed

    Schmied, Jürgen J; Raab, Mario; Forthmann, Carsten; Pibiri, Enrico; Wünsch, Bettina; Dammeyer, Thorben; Tinnefeld, Philip

    2014-01-01

    Validating and testing a fluorescence microscope or a microscopy method requires defined samples that can be used as standards. DNA origami is a new tool that provides a framework to place defined numbers of small molecules such as fluorescent dyes or proteins in a programmed geometry with nanometer precision. The flexibility and versatility in the design of DNA origami microscopy standards makes them ideally suited for the broad variety of emerging super-resolution microscopy methods. As DNA origami structures are durable and portable, they can become a universally available specimen to check the everyday functionality of a microscope. The standards are immobilized on a glass slide, and they can be imaged without further preparation and can be stored for up to 6 months. We describe a detailed protocol for the design, production and use of DNA origami microscopy standards, and we introduce a DNA origami rectangle, bundles and a nanopillar as fluorescent nanoscopic rulers. The protocol provides procedures for the design and realization of fluorescent marks on DNA origami structures, their production and purification, quality control, handling, immobilization, measurement and data analysis. The procedure can be completed in 1-2 d.

  17. Pretreatment with low-energy shock waves induces renal vasoconstriction during standard shock wave lithotripsy (SWL): a treatment protocol known to reduce SWL-induced renal injury.

    PubMed

    Handa, Rajash K; Bailey, Michael R; Paun, Marla; Gao, Sujuan; Connors, Bret A; Willis, Lynn R; Evan, Andrew P

    2009-05-01

    To test the hypothesis that the pretreatment of the kidney with low-energy shock waves (SWs) will induce renal vasoconstriction sooner than a standard clinical dose of high-energy SWs, thus providing a potential mechanism by which the pretreatment SW lithotripsy (SWL) protocol reduces tissue injury. Female farm pigs (6-weeks-old) were anaesthetized with isoflurane and the lower pole of the right kidney treated with SWs using a conventional electrohydraulic lithotripter (HM3, Dornier GmbH, Germany). Pulsed Doppler ultrasonography was used to measure renal resistive index (RI) in blood vessels as a measure of resistance/impedance to blood flow. RI was recorded from one intralobar artery located in the targeted pole of the kidney, and measurements taken from pigs given sham SW treatment (Group 1; no SWs, four pigs), a standard clinical dose of high-energy SWs (Group 2; 2000 SWs, 24 kV, 120 SWs/min, seven pigs), low-energy SW pretreatment followed by high-energy SWL (Group 3; 500 SWs, 12 kV, 120 SWs/min + 2000 SWs, 24 kV, 120 SWs/min, eight pigs) and low-energy SW pretreatment alone (Group 4; 500 SWs, 12 kV, 120 SWs/min, six pigs). Baseline RI (approximately 0.61) was similar for all groups. Pigs receiving sham SW treatment (Group 1) had no significant change in RI. A standard clinical dose of high-energy SWs (Group 2) did not significantly alter RI during treatment, but did increase RI at 45 min after SWL. Low-energy SWs did not alter RI in Group 3 pigs, but subsequent treatment with a standard clinical dose of high-energy SWs resulted in a significantly earlier (at 1000 SWs) and greater (two-fold) rise in RI than that in Group 2 pigs. This rise in RI during the low/high-energy SWL protocol was not due to a delayed vasoconstrictor response of pretreatment, as low-energy SW treatment alone (Group 4) did not increase RI until 65 min after SWL. The pretreatment protocol induces renal vasoconstriction during the period of SW application whereas the standard protocol shows vasoconstriction occurring after SWL. Thus, the earlier and greater rise in RI during the pretreatment protocol may be causally associated with a reduction in tissue injury.

  18. Influence of lead apron shielding on absorbed doses from panoramic radiography

    PubMed Central

    Rottke, D; Grossekettler, L; Sawada, K; Poxleitner, P; Schulze, D

    2013-01-01

    Objectives: This study investigated the absorbed doses in a full anthropomorphic body phantom from two different panoramic radiography devices, performing protocols with and without applying a lead apron. Methods: A RANDO® full body phantom (Alderson Research Laboratories Inc., Stamford, CT) was equipped with 110 thermoluminescent dosemeters at 55 different sites and set up in two different panoramic radiography devices [SCANORA® three-dimensional (3D) (SOREDEX, Tuusula, Finland) and ProMax® 3D (Planmeca, Helsinki, Finland)] and exposed. Two different protocols were performed in the two devices. The first protocol was performed without any lead shielding, whereas the phantom was equipped with a standard adult lead apron for the second protocol. Results: A two-tailed paired samples t-test for the SCANORA 3D revealed that there is no difference between the protocol using lead apron shielding (m = 87.99, s = 102.98) and the protocol without shielding (m = 87.34, s = 107.49), t(54) = −0.313, p > 0.05. The same test for the ProMax 3D showed that there is also no difference between the protocol using shielding (m = 106.48, s = 117.38) and the protocol without shielding (m = 107.75, s = 114,36), t(54) = 0.938, p > 0.05. Conclusions: In conclusion, the results of this study showed no statistically significant differences between a panoramic radiography with or without the use of lead apron shielding. PMID:24174012

  19. Influence of lead apron shielding on absorbed doses from panoramic radiography.

    PubMed

    Rottke, D; Grossekettler, L; Sawada, K; Poxleitner, P; Schulze, D

    2013-01-01

    This study investigated the absorbed doses in a full anthropomorphic body phantom from two different panoramic radiography devices, performing protocols with and without applying a lead apron. A RANDO(®) full body phantom (Alderson Research Laboratories Inc., Stamford, CT) was equipped with 110 thermoluminescent dosemeters at 55 different sites and set up in two different panoramic radiography devices [SCANORA(®) three-dimensional (3D) (SOREDEX, Tuusula, Finland) and ProMax(®) 3D (Planmeca, Helsinki, Finland)] and exposed. Two different protocols were performed in the two devices. The first protocol was performed without any lead shielding, whereas the phantom was equipped with a standard adult lead apron for the second protocol. A two-tailed paired samples t-test for the SCANORA 3D revealed that there is no difference between the protocol using lead apron shielding (m = 87.99, s = 102.98) and the protocol without shielding (m = 87.34, s = 107.49), t(54) = -0.313, p > 0.05. The same test for the ProMax 3D showed that there is also no difference between the protocol using shielding (m = 106.48, s = 117.38) and the protocol without shielding (m = 107.75, s = 114,36), t(54) = 0.938, p > 0.05. In conclusion, the results of this study showed no statistically significant differences between a panoramic radiography with or without the use of lead apron shielding.

  20. Influence of lead apron shielding on absorbed doses from panoramic radiography.

    PubMed

    Rottke, D; Grossekettler, L; Sawada, K; Poxleitner, P; Schulze, D

    2013-01-01

    This study investigated the absorbed doses in a full anthropomorphic body phantom from two different panoramic radiography devices, performing protocols with and without applying a lead apron. A RANDO® full body phantom (Alderson Research Laboratories Inc., Stamford, CT) was equipped with 110 thermoluminescent dosemeters at 55 different sites and set up in two different panoramic radiography devices [SCANORA® three-dimensional (3D) (SOREDEX, Tuusula, Finland) and ProMax® 3D (Planmeca, Helsinki, Finland)] and exposed. Two different protocols were performed in the two devices. The first protocol was performed without any lead shielding, whereas the phantom was equipped with a standard adult lead apron for the second protocol. A two-tailed paired samples t-test for the SCANORA 3D revealed that there is no difference between the protocol using lead apron shielding (m = 87.99, s = 102.98) and the protocol without shielding (m = 87.34, s = 107.49), t(54) = −0.313, p > 0.05. The same test for the ProMax 3D showed that there is also no difference between the protocol using shielding (m = 106.48, s = 117.38) and the protocol without shielding (m = 107.75, s = 114,36), t(54) = 0.938, p > 0.05. In conclusion, the results of this study showed no statistically significant differences between a panoramic radiography with or without the use of lead apron shielding.

  1. Development of a Protocol for Epidemiologal Studies of Whole-Body Vibration and Musculoskeletal Disorders of the Lower Back

    NASA Astrophysics Data System (ADS)

    Magnusson, M. L.; Pope, M. H.; Hulshof, C. T. J.; Bovenzi, M.

    1998-08-01

    It seems evident from a large number of studies that there is a positive relationship between exposure to whole body vibration (WBV) and the occurrence of low back pain. There are existing standards for evaluating the human exposure to WBV, which are based on other factors than the effect of musculoskeletal disorders. Several national and international standards also exist for evaluating human exposure to WBV. The exposure limit values or health guidance caution zones included in some of these standards are not or only to a limited extent based on systematic epidemiological investigations. It has not yet been possible to establish a clear exposure-response relationship. There are many confounding or contributing factors which influence the hazards to workers caused by exposure to WBV. Reliable methods for the detection and prevention of injury due to vibration exposure at work, alone or in combination with other risk factors, need to be implemented. The aim of this paper was to design a protocol and a questionnaire for conducting collaborative studies of WBV and musculoskeletal back disorders. The protocol will be tested in a pilot study before it will be used in multi-center studies.

  2. Validation of the Medisana MTP Plus upper arm blood pressure monitor, for self-measurement, according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Erdem, Emre; Aydogdu, Türkan; Akpolat, Tekin

    2011-02-01

    Standard validation protocols are objective guides for healthcare providers, physicians, and patients. The purpose of this study was to test validation of the Medisana MTP Plus upper arm blood pressure (BP) measuring monitor for self-measurement according to the European Society of Hypertension International Protocol (ESH-IP2) in adults. The Medisana MTP Plus monitor is an automated and oscillometric upper arm device for home BP monitoring. Nine consecutive measurements were made according to the ESH-IP2. Overseen by an independent supervisor, measurements were recorded by two observers blinded from both each other's readings and from the device readings. The Medisana MTP Plus device fulfills the validation criteria of the ESH-IP2 for the general population. The mean (standard deviation) of the difference between the observers and the device measurements was 0.6 mmHg (5.1 mmHg) for systolic and 2.7 mmHg (3.4 mmHg) for diastolic pressures, respectively. As the Medisana MTP Plus device has achieved the required standards, it is recommended for home BP monitoring in an adult population.

  3. Standardization and validation of real time PCR assays for the diagnosis of histoplasmosis using three molecular targets in an animal model

    PubMed Central

    López, Luisa F.; Muñoz, César O.; Cáceres, Diego H.; Tobón, Ángela M.; Loparev, Vladimir; Clay, Oliver; Chiller, Tom; Litvintseva, Anastasia; Gade, Lalitha; González, Ángel

    2017-01-01

    Histoplasmosis is considered one of the most important endemic and systemic mycoses worldwide. Until now few molecular techniques have been developed for its diagnosis. The aim of this study was to develop and evaluate three real time PCR (qPCR) protocols for different protein-coding genes (100-kDa, H and M antigens) using an animal model. Fresh and formalin-fixed and paraffin-embedded (FFPE) lung tissues from BALB/c mice inoculated i.n. with 2.5x106 Histoplasma capsulatum yeast or PBS were obtained at 1, 2, 3, 4, 8, 12 and 16 weeks post-infection. A collection of DNA from cultures representing different clades of H. capsulatum (30 strains) and other medically relevant pathogens (36 strains of related fungi and Mycobacterium tuberculosis) were used to analyze sensitivity and specificity. Analytical sensitivity and specificity were 100% when DNAs from the different strains were tested. The highest fungal burden occurred at first week post-infection and complete fungal clearance was observed after the third week; similar results were obtained when the presence of H. capsulatum yeast cells was demonstrated in histopathological analysis. In the first week post-infection, all fresh and FFPE lung tissues from H. capsulatum-infected animals were positive for the qPCR protocols tested except for the M antigen protocol, which gave variable results when fresh lung tissue samples were analyzed. In the second week, all qPCR protocols showed variable results for both fresh and FFPE tissues. Samples from the infected mice at the remaining times post-infection and uninfected mice (controls) were negative for all protocols. Good agreement was observed between CFUs, histopathological analysis and qPCR results for the 100-kDa and H antigen protocols. We successfully standardized and validated three qPCR assays for detecting H. capsulatum DNA in fresh and FFPE tissues, and conclude that the 100-kDa and H antigen molecular assays are promising tests for diagnosing this mycosis. PMID:29287097

  4. Effects of Guided Written Disclosure Protocol on mood states and psychological symptoms among parents of off-therapy acute lymphoblastic leukemia children.

    PubMed

    Martino, Maria Luisa; Freda, Maria Francesca; Camera, Flavia

    2013-06-01

    This study assesses the effects of Guided Written Disclosure Protocol on psychological distress in mothers and fathers of off-therapy acute lymphoblastic leukemia children. An experimental group participated in the writing intervention with a control group subject only to test-taking standards. The Symptom Questionnaire and Profile of Mood States were administered at baseline, post-intervention, and follow-up. Guided Written Disclosure Protocol had significant effects on the progressive reduction of anxiety, depression, somatic symptoms, hostility, tension-anxiety, and fatigue-inertia within the experimental group. However, the control group distress levels tended to worsen over time. The mediating role of emotional processing was highlighted.

  5. Development and initial evaluation of a reconstituted water formulation that better represents natural waters(poster)

    EPA Science Inventory

    The use of reconstituted waters is deeply entrenched in many standardized aquatic toxicity testing protocols The primary appeal of reconstituted waters is inter-laboratory comparability, such that experiments performed in different laboratories can be conducted in (nominally) id...

  6. Development and Initial Evaluation of a Reconstituted Water Formulation that Better Represents Natural Waters

    EPA Science Inventory

    The use of reconstituted waters is deeply entrenched in many standardized aquatic toxicity testing protocols. The primary appeal of reconstituted waters is inter-laboratory comparability, such that experiments performed in different laboratories can be conducted in (nominally) id...

  7. DEVELOPMENT OF A PROTOCOL FOR TESTING EFFECTS OF TOXIC SUBSTANCES ON PLANTS

    EPA Science Inventory

    This study was designed to devise a rapid, simple, reproducible bioassay procedure to determine effects of so-called 'toxic substances in the environment' on vegetation and provide a standardized procedure for evaluation and comparison of effects of diverse compounds. Eight diffe...

  8. Three-dimensional assessment of the asymptomatic and post-stroke shoulder: intra-rater test-retest reliability and within-subject repeatability of the palpation and digitization approach.

    PubMed

    Pain, Liza A M; Baker, Ross; Sohail, Qazi Zain; Richardson, Denyse; Zabjek, Karl; Mogk, Jeremy P M; Agur, Anne M R

    2018-03-23

    Altered three-dimensional (3D) joint kinematics can contribute to shoulder pathology, including post-stroke shoulder pain. Reliable assessment methods enable comparative studies between asymptomatic shoulders of healthy subjects and painful shoulders of post-stroke subjects, and could inform treatment planning for post-stroke shoulder pain. The study purpose was to establish intra-rater test-retest reliability and within-subject repeatability of a palpation/digitization protocol, which assesses 3D clavicular/scapular/humeral rotations, in asymptomatic and painful post-stroke shoulders. Repeated measurements of 3D clavicular/scapular/humeral joint/segment rotations were obtained using palpation/digitization in 32 asymptomatic and six painful post-stroke shoulders during four reaching postures (rest/flexion/abduction/external rotation). Intra-class correlation coefficients (ICCs), standard error of the measurement and 95% confidence intervals were calculated. All ICC values indicated high to very high test-retest reliability (≥0.70), with lower reliability for scapular anterior/posterior tilt during external rotation in asymptomatic subjects, and scapular medial/lateral rotation, humeral horizontal abduction/adduction and axial rotation during abduction in post-stroke subjects. All standard error of measurement values demonstrated within-subject repeatability error ≤5° for all clavicular/scapular/humeral joint/segment rotations (asymptomatic ≤3.75°; post-stroke ≤5.0°), except for humeral axial rotation (asymptomatic ≤5°; post-stroke ≤15°). This noninvasive, clinically feasible palpation/digitization protocol was reliable and repeatable in asymptomatic shoulders, and in a smaller sample of painful post-stroke shoulders. Implications for Rehabilitation In the clinical setting, a reliable and repeatable noninvasive method for assessment of three-dimensional (3D) clavicular/scapular/humeral joint orientation and range of motion (ROM) is currently required. The established reliability and repeatability of this proposed palpation/digitization protocol will enable comparative 3D ROM studies between asymptomatic and post-stroke shoulders, which will further inform treatment planning. Intra-rater test-retest repeatability, which is measured by the standard error of the measure, indicates the range of error associated with a single test measure. Therefore, clinicians can use the standard error of the measure to determine the "true" differences between pre-treatment and post-treatment test scores.

  9. Mobile phone-based clinical guidance for rural health providers in India.

    PubMed

    Gautham, Meenakshi; Iyengar, M Sriram; Johnson, Craig W

    2015-12-01

    There are few tried and tested mobile technology applications to enhance and standardize the quality of health care by frontline rural health providers in low-resource settings. We developed a media-rich, mobile phone-based clinical guidance system for management of fevers, diarrhoeas and respiratory problems by rural health providers. Using a randomized control design, we field tested this application with 16 rural health providers and 128 patients at two rural/tribal sites in Tamil Nadu, Southern India. Protocol compliance for both groups, phone usability, acceptability and patient feedback for the experimental group were evaluated. Linear mixed-model analyses showed statistically significant improvements in protocol compliance in the experimental group. Usability and acceptability among patients and rural health providers were very high. Our results indicate that mobile phone-based, media-rich procedural guidance applications have significant potential for achieving consistently standardized quality of care by diverse frontline rural health providers, with patient acceptance. © The Author(s) 2014.

  10. Cleaning and Sterilization of Used Cardiac Implantable Electronic Devices With Process Validation: The Next Hurdle in Device Recycling.

    PubMed

    Crawford, Thomas C; Allmendinger, Craig; Snell, Jay; Weatherwax, Kevin; Lavan, Balasundaram; Baman, Timir S; Sovitch, Pat; Alyesh, Daniel; Carrigan, Thomas; Klugman, Noah; Kune, Denis; Hughey, Andrew; Lautenbach, Daniel; Sovitch, Nathan; Tandon, Karman; Samson, George; Newman, Charles; Davis, Sheldon; Brown, Archie; Wasserman, Brad; Goldman, Ed; Arlinghaus, Sandra L; Oral, Hakan; Eagle, Kim A

    2017-06-01

    This study sought to develop a validated, reproducible sterilization protocol, which could be used in the reprocessing of cardiac implantable electronic devices (CIEDs). Access to cardiac CIED therapy in high-income and in low- and middle-income countries varies greatly. CIED reuse may reduce this disparity. A cleaning and sterilization protocol was developed that includes washing CIEDs in an enzymatic detergent, screw cap and set screw replacement, brushing, inspection, and sterilization in ethylene oxide. Validation testing was performed to assure compliance with accepted standards. With cleaning, the total mean bioburden for each of 3 batches of 10 randomly chosen devices was reduced from 754 to 10.1 colony-forming units. After sterilization with ethylene oxide, with 3 half-cycle and 3 full-cycle processes, none of the 90 biological indicator testers exhibited growth after 7 days. Through cleaning and sterilization, protein and hemoglobin concentrations were reduced from 99.2 to 1.42 μg/cm 2 and from 21.4 to 1.03 μg/cm 2 , respectively. Mean total organic carbon residual was 1.44 parts per million (range 0.36 to 2.9 parts per million). Endotoxin concentration was not detectable at the threshold of <0.03 endotoxin units/ml or <3.0 endotoxin units/device. Cytotoxicity and intracutaneous reactivity tests met the standards set by the Association for Advancement of Medical Instrumentation and the International Organization for Standardization. CIEDs can be cleaned and sterilized according to a standardized protocol achieving a 12-log reduction of inoculated product, resulting in sterility assurance level of 10 -6 . Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  11. Validation of the BPLab(®) 24-hour blood pressure monitoring system according to the European standard BS EN 1060-4:2004 and British Hypertension Society protocol.

    PubMed

    Koudryavtcev, Sergey A; Lazarev, Vyacheslav M

    2011-01-01

    Automatic blood pressure (BP) measuring devices are more and more often used in BP self-checks and in 24-hour BP monitoring. Nowadays, 24-hour BP monitoring is a necessary procedure in arterial hypertension treatment. The aim of this study was to validate the BPLab(®) ambulatory blood pressure monitor according to the European standard BS EN 1060-4:2004 and the British Hypertension Society (BHS) protocol, as well as to work out solutions regarding the suitability of using this device in clinical practice. A group of 85 patients of both sexes and different ages, who voluntarily agreed to take part in the tests and were given detailed instructions on the measurement technique were recruited for this study. The results of the BP measurement obtained by a qualified operator using the BPLab(®) device were compared with the BP values measured using the Korotkov auscultatory method. Data were obtained simultaneously by two experts with experience of over 10 years and had completed a noninvasive BP measurement standardization training course. Discrepancies in the systolic and diastolic BP measurements (N = 510; 255 for each expert) were analyzed according to the criteria specified in the BHS-93 protocol. The device passed the requirements of the European Standard BS EN 1060-4:2004 and was graded 'A' according to the criteria of the BHS protocol for both systolic BP and diastolic BP. The BPLab(®) 24-hour ambulatory blood pressure monitoring device may be recommended for extensive clinical use.

  12. Effect of a Standardized Protocol of Antibiotic Therapy on Surgical Site Infection after Laparoscopic Surgery for Complicated Appendicitis.

    PubMed

    Park, Hyoung-Chul; Kim, Min Jeong; Lee, Bong Hwa

    Although it is accepted that complicated appendicitis requires antibiotic therapy to prevent post-operative surgical infections, consensus protocols on the duration and regimens of treatment are not well established. This study aimed to compare the outcome of post-operative infectious complications in patients receiving old non-standardized and new standard antibiotic protocols, involving either 5 or 10 days of treatment, respectively. We enrolled 1,343 patients who underwent laparoscopic surgery for complicated appendicitis between January 2009 and December 2014. At the beginning of the new protocol, the patients were divided into two groups; 10 days of various antibiotic regimens (between January 2009 and June 2012, called the non-standardized protocol; n = 730) and five days of cefuroxime and metronidazole regimen (between July 2012 and December 2014; standardized protocol; n = 613). We compared the clinical outcomes, including surgical site infection (SSI) (superficial and deep organ/space infections) in the two groups. The standardized protocol group had a slightly shorter operative time (67 vs. 69 min), a shorter hospital stay (5 vs. 5.4 d), and lower medical cost (US$1,564 vs. US$1,654). Otherwise, there was no difference between the groups. No differences were found in the non-standardized and standard protocol groups with regard to the rate of superficial infection (10.3% vs. 12.7%; p = 0.488) or deep organ/space infection (2.3% vs. 2.1%; p = 0.797). In patients undergoing laparoscopic surgery for complicated appendicitis, five days of cefuroxime and metronidazole did not lead to more SSIs, and it decreased the medical costs compared with non-standardized antibiotic regimens.

  13. Integration of GC-MSD and ER-Calux® assay into a single protocol for determining steroid estrogens in environmental samples.

    PubMed

    Avberšek, Miha; Žegura, Bojana; Filipič, Metka; Heath, Ester

    2011-11-01

    There are many published studies that use either chemical or biological methods to investigate steroid estrogens in the aquatic environment, but rarer are those that combine both. In this study, gas chromatography with mass selective detection (GC-MSD) and the ER-Calux(®) estrogenicity assay were integrated into a single protocol for simultaneous determination of natural (estrone--E1, 17β-estradiol--E2, estriol--E3) and synthetic (17α-ethinylestradiol--EE2) steroid estrogens concentrations and the total estrogenic potential of environmental samples. For integration purposes, several solvents were investigated and the commonly used dimethyl sulphoxide (DMSO) in the ER-Calux(®) assay was replaced by ethyl acetate, which is more compatible with gas chromatography and enables the same sample to be analysed by both GC-MSD and the ER-Calux(®) assay. The integrated protocol was initially tested using a standard mixture of estrogens. The results for pure standards showed that the estrogenicity calculated on the basis of GC-MSD and the ER-Calux(®) assay exhibited good correlation (r(2)=0.96; α=0.94). The result remained the same when spiked waste water extracts were tested (r(2)=0.92, α=1.02). When applied to real waste water influent and effluent samples the results proved (r(2)=0.93; α=0.99) the applicability of the protocol. The main advantages of this newly developed protocol are simple sample handling for both methods, and reduced material consumption and labour. In addition, it can be applied as either a complete or sequential analysis where the ER-Calux(®) assay is used as a pre-screening method prior to the chemical analysis. Copyright © 2011 Elsevier B.V. All rights reserved.

  14. Blood gas testing and related measurements: National recommendations on behalf of the Croatian Society of Medical Biochemistry and Laboratory Medicine.

    PubMed

    Dukić, Lora; Kopčinović, Lara Milevoj; Dorotić, Adrijana; Baršić, Ivana

    2016-10-15

    Blood gas analysis (BGA) is exposed to risks of errors caused by improper sampling, transport and storage conditions. The Clinical and Laboratory Standards Institute (CLSI) generated documents with recommendations for avoidance of potential errors caused by sample mishandling. Two main documents related to BGA issued by the CLSI are GP43-A4 (former H11-A4) Procedures for the collection of arterial blood specimens; approved standard - fourth edition, and C46-A2 Blood gas and pH analysis and related measurements; approved guideline - second edition. Practices related to processing of blood gas samples are not standardized in the Republic of Croatia. Each institution has its own protocol for ordering, collection and analysis of blood gases. Although many laboratories use state of the art analyzers, still many preanalytical procedures remain unchanged. The objective of the Croatian Society of Medical Biochemistry and Laboratory Medicine (CSMBLM) is to standardize the procedures for BGA based on CLSI recommendations. The Working Group for Blood Gas Testing as part of the Committee for the Scientific Professional Development of the CSMBLM prepared a set of recommended protocols for sampling, transport, storage and processing of blood gas samples based on relevant CLSI documents, relevant literature search and on the results of Croatian survey study on practices and policies in acid-base testing. Recommendations are intended for laboratory professionals and all healthcare workers involved in blood gas processing.

  15. Blood gas testing and related measurements: National recommendations on behalf of the Croatian Society of Medical Biochemistry and Laboratory Medicine

    PubMed Central

    Dukić, Lora; Kopčinović, Lara Milevoj; Dorotić, Adrijana; Baršić, Ivana

    2016-01-01

    Blood gas analysis (BGA) is exposed to risks of errors caused by improper sampling, transport and storage conditions. The Clinical and Laboratory Standards Institute (CLSI) generated documents with recommendations for avoidance of potential errors caused by sample mishandling. Two main documents related to BGA issued by the CLSI are GP43-A4 (former H11-A4) Procedures for the collection of arterial blood specimens; approved standard – fourth edition, and C46-A2 Blood gas and pH analysis and related measurements; approved guideline – second edition. Practices related to processing of blood gas samples are not standardized in the Republic of Croatia. Each institution has its own protocol for ordering, collection and analysis of blood gases. Although many laboratories use state of the art analyzers, still many preanalytical procedures remain unchanged. The objective of the Croatian Society of Medical Biochemistry and Laboratory Medicine (CSMBLM) is to standardize the procedures for BGA based on CLSI recommendations. The Working Group for Blood Gas Testing as part of the Committee for the Scientific Professional Development of the CSMBLM prepared a set of recommended protocols for sampling, transport, storage and processing of blood gas samples based on relevant CLSI documents, relevant literature search and on the results of Croatian survey study on practices and policies in acid-base testing. Recommendations are intended for laboratory professionals and all healthcare workers involved in blood gas processing. PMID:27812301

  16. Performance Comparison of Wireless Sensor Network Standard Protocols in an Aerospace Environment: ISA100.11a and ZigBee

    NASA Technical Reports Server (NTRS)

    Wagner, Raymond S.; Barton, Richard J.

    2011-01-01

    Wireless Sensor Networks (WSNs) can provide a substantial benefit in spacecraft systems, reducing launch weight and providing unprecedented flexibility by allowing instrumentation capabilities to grow and change over time. Achieving data transport reliability on par with that of wired systems, however, can prove extremely challenging in practice. Fortunately, much progress has been made in developing standard WSN radio protocols for applications from non-critical home automation to mission-critical industrial process control. The relative performances of candidate protocols must be compared in representative aerospace environments, however, to determine their suitability for spaceflight applications. In this paper, we will present the results of a rigorous laboratory analysis of the performance of two standards-based, low power, low data rate WSN protocols: ZigBee Pro and ISA100.11a. Both are based on IEEE 802.15.4 and augment that standard's specifications to build complete, multi-hop networking stacks. ZigBee Pro targets primarily the home and office automation markets, providing an ad-hoc protocol that is computationally lightweight and easy to implement in inexpensive system-on-a-chip components. As a result of this simplicity, however, ZigBee Pro can be susceptible to radio frequency (RF) interference. ISA100.11a, on the other hand, targets the industrial process control market, providing a robust, centrally-managed protocol capable of tolerating a significant amount of RF interference. To achieve these gains, a coordinated channel hopping mechanism is employed, which entails a greater computational complexity than ZigBee and requires more sophisticated and costly hardware. To guide future aerospace deployments, we must understand how well these standards relatively perform in analog environments under expected operating conditions. Specifically, we are interested in evaluating goodput -- application level throughput -- in a representative crewed environment in the presence of varying levels of 802.11g Wi-Fi traffic. To do so, we use the NASA Johnson Space Center Wireless Habitat Testbed (WHT), a metallic, habitation-sized module designed for co-existence testing of wireless systems. In its quiescent state, the sealed WHT provides an RF-quiet environment to which we can selectively add interfering systems; it also provides a realistic level of multi-path self-interference for systems under investigation. In our test, we deploy two representative five node networks, configured in a star topology with all nodes reporting directly to a WSN gateway. Each ZigBee network WSN node is built using a Texas Instruments (TI) CC2530 system-on-a-chip radio running TI's ZigBee Pro Z-stack. Each ISA100.11a network node is built using a Nivis VersaNode 210 system-on-a-chip radio. In both cases, radios interface with TI MSP430-F5438 microcontroller implementing a common test application. Interference is provided by a D-link 802.11g Wi-Fi router transporting traffic generated using the Iperf network testing tool. For the single-channel ZigBee network, effects of both direct and indirect Wi-Fi interference are evaluated. For the channel-hopping ISA100.11a network, effects of interference from multiple Wi-Fi routers configured in non-overlapping 802.11g channels are evaluated. Our results show that, in general, the more lightweight ZigBee network performs well at low interference levels, but performance degrades as interference increases. Conversely, the more complex and costly ISA100.11a network continues to perform well as Wi-Fi interference levels increase.

  17. Natural Language Processing-Enabled and Conventional Data Capture Methods for Input to Electronic Health Records: A Comparative Usability Study.

    PubMed

    Kaufman, David R; Sheehan, Barbara; Stetson, Peter; Bhatt, Ashish R; Field, Adele I; Patel, Chirag; Maisel, James Mark

    2016-10-28

    The process of documentation in electronic health records (EHRs) is known to be time consuming, inefficient, and cumbersome. The use of dictation coupled with manual transcription has become an increasingly common practice. In recent years, natural language processing (NLP)-enabled data capture has become a viable alternative for data entry. It enables the clinician to maintain control of the process and potentially reduce the documentation burden. The question remains how this NLP-enabled workflow will impact EHR usability and whether it can meet the structured data and other EHR requirements while enhancing the user's experience. The objective of this study is evaluate the comparative effectiveness of an NLP-enabled data capture method using dictation and data extraction from transcribed documents (NLP Entry) in terms of documentation time, documentation quality, and usability versus standard EHR keyboard-and-mouse data entry. This formative study investigated the results of using 4 combinations of NLP Entry and Standard Entry methods ("protocols") of EHR data capture. We compared a novel dictation-based protocol using MediSapien NLP (NLP-NLP) for structured data capture against a standard structured data capture protocol (Standard-Standard) as well as 2 novel hybrid protocols (NLP-Standard and Standard-NLP). The 31 participants included neurologists, cardiologists, and nephrologists. Participants generated 4 consultation or admission notes using 4 documentation protocols. We recorded the time on task, documentation quality (using the Physician Documentation Quality Instrument, PDQI-9), and usability of the documentation processes. A total of 118 notes were documented across the 3 subject areas. The NLP-NLP protocol required a median of 5.2 minutes per cardiology note, 7.3 minutes per nephrology note, and 8.5 minutes per neurology note compared with 16.9, 20.7, and 21.2 minutes, respectively, using the Standard-Standard protocol and 13.8, 21.3, and 18.7 minutes using the Standard-NLP protocol (1 of 2 hybrid methods). Using 8 out of 9 characteristics measured by the PDQI-9 instrument, the NLP-NLP protocol received a median quality score sum of 24.5; the Standard-Standard protocol received a median sum of 29; and the Standard-NLP protocol received a median sum of 29.5. The mean total score of the usability measure was 36.7 when the participants used the NLP-NLP protocol compared with 30.3 when they used the Standard-Standard protocol. In this study, the feasibility of an approach to EHR data capture involving the application of NLP to transcribed dictation was demonstrated. This novel dictation-based approach has the potential to reduce the time required for documentation and improve usability while maintaining documentation quality. Future research will evaluate the NLP-based EHR data capture approach in a clinical setting. It is reasonable to assert that EHRs will increasingly use NLP-enabled data entry tools such as MediSapien NLP because they hold promise for enhancing the documentation process and end-user experience. ©David R. Kaufman, Barbara Sheehan, Peter Stetson, Ashish R. Bhatt, Adele I. Field, Chirag Patel, James Mark Maisel. Originally published in JMIR Medical Informatics (http://medinform.jmir.org), 28.10.2016.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nielsen, Yousef W., E-mail: yujwni01@heh.regionh.d; Eiberg, Jonas P., E-mail: Eiberg@dadlnet.d; Logager, Vibeke B., E-mail: viloe@heh.regionh.d

    The purpose of this study was to determine the diagnostic performance of 3T whole-body magnetic resonance angiography (WB-MRA) using a hybrid protocol in comparison with a standard protocol in patients with peripheral arterial disease (PAD). In 26 consecutive patients with PAD two different protocols were used for WB-MRA: a standard sequential protocol (n = 13) and a hybrid protocol (n = 13). WB-MRA was performed using a gradient echo sequence, body coil for signal reception, and gadoterate meglumine as contrast agent (0.3 mmol/kg body weight). Two blinded observers evaluated all WB-MRA examinations with regard to presence of stenoses, as wellmore » as diagnostic quality and degree of venous contamination in each of the four stations used in WB-MRA. Digital subtraction angiography served as the method of reference. Sensitivity for detecting significant arterial disease (luminal narrowing {>=} 50%) using standard-protocol WB-MRA for the two observers was 0.63 (95%CI: 0.51-0.73) and 0.66 (0.58-0.78). Specificities were 0.94 (0.91-0.97) and 0.96 (0.92-0.98), respectively. In the hybrid protocol WB-MRA sensitivities were 0.75 (0.64-0.84) and 0.70 (0.58-0.8), respectively. Specificities were 0.93 (0.88-0.96) and 0.95 (0.91-0.97). Interobserver agreement was good using both the standard and the hybrid protocol, with {kappa} = 0.62 (0.44-0.67) and {kappa} = 0.70 (0.59-0.79), respectively. WB-MRA quality scores were significantly higher in the lower leg using the hybrid protocol compared to standard protocol (p = 0.003 and p = 0.03, observers 1 and 2). Distal venous contamination scores were significantly lower with the hybrid protocol (p = 0.02 and p = 0.01, observers 1 and 2). In conclusion, hybrid-protocol WB-MRA shows a better diagnostic performance than standard protocol WB-MRA at 3 T in patients with PAD.« less

  19. Application Protocol, Initial Graphics Exchange Specification (IGES), Layered Electrical Product

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O`Connell, L.J.

    1994-12-01

    An application protocol is an information systems engineering view of a specific product The view represents an agreement on the generic activities needed to design and fabricate the product the agreement on the information needed to support those activities, and the specific constructs of a product data standard for use in transferring some or all of the information required. This application protocol describes the data for electrical and electronic products in terms of a product description standard called the Initial Graphics Exchange Specification (IGES). More specifically, the Layered Electrical Product IGES Application Protocol (AP) specifies the mechanisms for defining andmore » exchanging computer-models and their associated data for those products which have been designed in two dimensional geometry so as to be produced as a series of layers in IGES format The AP defines the appropriateness of the data items for describing the geometry of the various parts of a product (shape and location), the connectivity, and the processing and material characteristics. Excluded is the behavioral requirements which the product was intended to satisfy, except as those requirements have been recorded as design rules or product testing requirements.« less

  20. Layered Electrical Product Application Protocol (AP). Draft: Initial Graphics Exchange Specification (IGES)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1994-09-01

    An application protocol is an information systems engineering view of a specific product. The view represents an agreement on the generic activities needed to design and fabricate the product, the agreement on the information needed to support those activities, and the specific constructs of a product data standard for use in transfering some or all of the information required. This applications protocol describes the data for electrical and electronic products in terms of a product description standard called the Initial Graphics Exchange Specification (IGES). More specifically, the Layered Electrical Product IGES Application Protocol (AP) specifies the mechanisms for defining andmore » exchanging computer-models and their associated data for those products which have been designed in two dimensional geometry so as to be produced as a series of layers in IGES format. The AP defines the appropriateness of the data items for describing the geometry of the various parts of a product (shape and location), the connectivity, and the processing and material characteristics. Excluded is the behavioral requirements which the product was intended to satisfy, except as those requirements have been recorded as design rules or product testing requirements.« less

  1. The deployment of a large scale object store at the RAL Tier-1

    NASA Astrophysics Data System (ADS)

    Dewhurst, A.; Johnson, I.; Adams, J.; Canning, B.; Vasilakakos, G.; Packer, A.

    2017-10-01

    Since 2014, the RAL Tier-1 has been working on deploying a Ceph backed object store. The aim is to replace Castor for disk-only storage. This new service must be scalable to meet the data demands of the LHC to 2020 and beyond. As well as offering access protocols the LHC experiments currently use, it must also provide industry standard access protocols. In order to keep costs down the service must use erasure coding rather than replication to ensure data reliability. This paper will present details of the storage service setup, which has been named Echo, as well as the experience gained from running it. The RAL Tier-1 has also been developing XrootD and GridFTP plugins for Ceph. Both plugins are built on top of the same libraries that write striped data into Ceph and therefore data written by one protocol will be accessible by the other. In the long term we hope the LHC experiments will migrate to industry standard protocols, therefore these plugins will only provide the features needed by the LHC experiments. This paper will report on the development and testing of these plugins.

  2. Proposed test method for and evaluation of wheelchair seating system (WCSS) crashworthiness.

    PubMed

    van Roosmalen, L; Bertocci, G; Ha, D R; Karg, P; Szobota, S

    2000-01-01

    Safety of motor vehicle seats is of great importance in providing crash protection to the occupant. An increasing number of wheelchair users use their wheelchairs as motor vehicle seats when traveling. A voluntary standard requires that compliant wheelchairs be dynamically sled impact tested. However, testing to evaluate the crashworthiness of add-on wheelchair seating systems (WCSS) independent of their wheelchair frame is not addressed by this standard. To address this need, this study developed a method to evaluate the crash-worthiness of WCSS with independent frames. Federal Motor Vehicle Safety Standards (FMVSS) 207 test protocols, used to test the strength of motor vehicle seats, were modified and used to test the strength of three WCSS. Forward and rearward loads were applied at the WCSS center of gravity (CGSS), and a moment was applied at the uppermost point of the seat back. Each of the three tested WCSS met the strength requirements of FMVSS 207. Wheelchair seat-back stiffness was also investigated and compared to motor vehicle seat-back stiffness.

  3. ACTS 118x: High Speed TCP Interoperability Testing

    NASA Technical Reports Server (NTRS)

    Brooks, David E.; Buffinton, Craig; Beering, Dave R.; Welch, Arun; Ivancic, William D.; Zernic, Mike; Hoder, Douglas J.

    1999-01-01

    With the recent explosion of the Internet and the enormous business opportunities available to communication system providers, great interest has developed in improving the efficiency of data transfer over satellite links using the Transmission Control Protocol (TCP) of the Internet Protocol (IP) suite. The NASA's ACTS experiments program initiated a series of TCP experiments to demonstrate scalability of TCP/IP and determine to what extent the protocol can be optimized over a 622 Mbps satellite link. Through partnerships with the government technology oriented labs, computer, telecommunication, and satellite industries NASA Glenn was able to: (1) promote the development of interoperable, high-performance TCP/IP implementations across multiple computing / operating platforms; (2) work with the satellite industry to answer outstanding questions regarding the use of standard protocols (TCP/IP and ATM) for the delivery of advanced data services, and for use in spacecraft architectures; and (3) conduct a series of TCP/IP interoperability tests over OC12 ATM over a satellite network in a multi-vendor environment using ACTS. The experiments' various network configurations and the results are presented.

  4. Automating individualized coaching and authentic role-play practice for brief intervention training.

    PubMed

    Hayes-Roth, B; Saker, R; Amano, K

    2010-01-01

    Brief intervention helps to reduce alcohol abuse, but there is a need for accessible, cost-effective training of clinicians. This study evaluated STAR Workshop , a web-based training system that automates efficacious techniques for individualized coaching and authentic role-play practice. We compared STAR Workshop to a web-based, self-guided e-book and a no-treatment control, for training the Engage for Change (E4C) brief intervention protocol. Subjects were medical and nursing students. Brief written skill probes tested subjects' performance of individual protocol steps, in different clinical scenarios, at three test times: pre-training, post-training, and post-delay (two weeks). Subjects also did live phone interviews with a standardized patient, post-delay. STAR subjects performed significantly better than both other groups. They showed significantly greater improvement from pre-training probes to post-training and post-delay probes. They scored significantly higher on post-delay phone interviews. STAR Workshop appears to be an accessible, cost-effective approach for training students to use the E4C protocol for brief intervention in alcohol abuse. It may also be useful for training other clinical interviewing protocols.

  5. Thermal Changes During Guided Flapless Implant Site Preparation: A Comparative Study.

    PubMed

    Sannino, Gianpaolo; Gherlone, Enrico F

    To compare intrabony thermal changes induced by two different protocols for guided implant surgery during the whole drilling procedure. Two protocols for guided implant placement were evaluated in vitro using artificial bone cylinders. The control protocol provided traditional metal sleeves and a standard drilling sequence composed of four cylindrical triflute drills (cutting surface length = 16 mm). The test protocol provided a three-slot polyurethane sleeve and two cylindrical drills (second drill cutting surface length = 4 mm). Forty automated intermittent and graduated osteotomies (depth = 14 mm) were performed under external irrigation. Temperatures were measured in real time by three sensors at different depths (2, 8, and 13 mm). The temperature changes generated by the final drill of each protocol during the shearing and withdrawing processes were recorded as experimental results and subjected to the Student t test. Maximum temperature increases were recorded during the process of withdrawing in both protocols. In the control group, the mean thermal changes were 10.18°C, 8.61°C, and 5.78°C at depths of 2, 8, and 13 mm, respectively. In the test group, the mean thermal changes were 1.44°C, 4.46°C, and 3.58°C at depths of 2, 8, and 13 mm, respectively. The control group revealed statistically significantly (P < .0001) higher thermal changes than the test group, both in the superficial and deeper bone areas. An appropriate irrigation system could be crucial for thermal lowering during a guided implant osteotomy mainly in the coronal and middle third of the implant site. Copious irrigation should be provided during the withdrawing process since greater thermal increases could be expected. Lower temperature increases could be achieved, reducing drill-to-bone contact, ie, cutting surface length, due to short frictional force exposure.

  6. Evaluation of cleaning and disinfection performance of automatic washer disinfectors machines in programs presenting different cycle times and temperatures.

    PubMed

    Bergo, Maria do Carmo Noronha Cominato

    2006-01-01

    Thermal washer-disinfectors represent a technology that brought about great advantages such as, establishment of protocols, standard operating procedures, reduction in occupational risk of a biological and environmental nature. The efficacy of the cleaning and disinfection obtained by automatic washer disinfectors machines in running programs with different times and temperatures determined by the different official agencies was validated according to recommendations from ISO Standards 15883-1/1999 and HTM2030 (NHS Estates, 1997) for the determining of the Minimum Lethality and DAL both theoretically and through the use with thermocouples. In order to determine the cleaning efficacy, the Soil Test, Biotrace Pro-tect and the Protein Test Kit were used. The procedure to verify the CFU count of viable microorganisms was performed before and after the thermal disinfection. This article shows that the results are in compliance with the ISO and HTM Standards. The validation steps confirmed the high efficacy level of the Medical Washer-Disinfectors. This protocol enabled the evaluation of the procedure based on evidence supported by scientific research, aiming at the support of the Supply Center multi-professional personnel with information and the possibility of developing further research.

  7. A protocol for rheological characterization of hydrogels for tissue engineering strategies.

    PubMed

    Zuidema, Jonathan M; Rivet, Christopher J; Gilbert, Ryan J; Morrison, Faith A

    2014-07-01

    Hydrogels are studied extensively for many tissue engineering applications, and their mechanical properties influence both cellular and tissue compatibility. However, it is difficult to compare the mechanical properties of hydrogels between studies due to a lack of continuity between rheological protocols. This study outlines a straightforward protocol to accurately determine hydrogel equilibrium modulus and gelation time using a series of rheological tests. These protocols are applied to several hydrogel systems used within tissue engineering applications: agarose, collagen, fibrin, Matrigel™, and methylcellulose. The protocol is outlined in four steps: (1) Time sweep to determine the gelation time of the hydrogel. (2) Strain sweep to determine the linear-viscoelastic region of the hydrogel with respect to strain. (3) Frequency sweep to determine the linear equilibrium modulus plateau of the hydrogel. (4) Time sweep with values obtained from strain and frequency sweeps to accurately report the equilibrium moduli and gelation time. Finally, the rheological characterization protocol was evaluated using a composite Matrigel™-methylcellulose hydrogel blend whose mechanical properties were previously unknown. The protocol described herein provides a standardized approach for proper analysis of hydrogel rheological properties. © 2013 Wiley Periodicals, Inc.

  8. Basal measures of insulin sensitivity and insulin secretion and simplified glucose tolerance tests in dogs.

    PubMed

    Verkest, K R; Fleeman, L M; Rand, J S; Morton, J M

    2010-10-01

    There is need for simple, inexpensive measures of glucose tolerance, insulin sensitivity, and insulin secretion in dogs. The aim of this study was to estimate the closeness of correlation between fasting and dynamic measures of insulin sensitivity and insulin secretion, the precision of fasting measures, and the agreement between results of standard and simplified glucose tolerance tests in dogs. A retrospective descriptive study using 6 naturally occurring obese and 6 lean dogs was conducted. Data from frequently sampled intravenous glucose tolerance tests (FSIGTTs) in 6 obese and 6 lean client-owned dogs were used to calculate HOMA, QUICKI, fasting glucose and insulin concentrations. Fasting measures of insulin sensitivity and secretion were compared with MINMOD analysis of FSIGTTs using Pearson correlation coefficients, and they were evaluated for precision by the discriminant ratio. Simplified sampling protocols were compared with standard FSIGTTs using Lin's concordance correlation coefficients, limits of agreement, and Pearson correlation coefficients. All fasting measures except fasting plasma glucose concentration were moderately correlated with MINMOD-estimated insulin sensitivity (|r| = 0.62-0.80; P < 0.03), and those that combined fasting insulin and glucose were moderately closely correlated with MINMOD-estimated insulin secretion (r = 0.60-0.79; P < 0.04). HOMA calculated using the nonlinear formulae had the closest estimated correlation (r = 0.77 and 0.74) and the best discrimination for insulin sensitivity and insulin secretion (discriminant ratio 4.4 and 3.4, respectively). Simplified sampling protocols with half as many samples collected over 3 h had close agreement with the full sampling protocol. Fasting measures and simplified intravenous glucose tolerance tests reflect insulin sensitivity and insulin secretion derived from frequently sampled glucose tolerance tests with MINMOD analysis in dogs. Copyright 2010 Elsevier Inc. All rights reserved.

  9. Automation of serum (1→3)-beta-D-glucan testing allows reliable and rapid discrimination of patients with and without candidemia.

    PubMed

    Prüller, Florian; Wagner, Jasmin; Raggam, Reinhard B; Hoenigl, Martin; Kessler, Harald H; Truschnig-Wilders, Martie; Krause, Robert

    2014-07-01

    Testing for (1→3)-beta-D-glucan (BDG) is used for detection of invasive fungal infection. However, current assays lack automation and the ability to conduct rapid single-sample testing. The Fungitell assay was adopted for automation and evaluated using clinical samples from patients with culture-proven candidemia and from culture-negative controls in duplicate. A comparison with the standard assay protocol was made in order to establish analytical specifications. With the automated protocol, the analytical measuring range was 8-2500 pg/ml of BDG, and precision testing resulted in coefficients of variation that ranged from 3.0% to 5.5%. Samples from 15 patients with culture-proven candidemia and 94 culture-negative samples were evaluated. All culture-proven samples showed BDG values >80 pg/ml (mean 1247 pg/ml; range, 116-2990 pg/ml), which were considered positive. Of the 94 culture-negative samples, 92 had BDG values <60 pg/ml (mean, 28 pg/ml), which were considered to be negative, and 2 samples were false-positive (≥80 pg/ml; up to 124 pg/ml). Results could be obtained within 45 min and showed excellent agreement with results obtained with the standard assay protocol. The automated Fungitell assay proved to be reliable and rapid for diagnosis of candidemia. It was demonstrated to be feasible and cost efficient for both single-sample and large-scale testing of serum BDG. Its 1-h time-to-result will allow better support for clinicians in the management of antifungal therapy. © The Author 2014. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  10. Space-Based Telemetry and Range Safety (STARS) Study

    NASA Technical Reports Server (NTRS)

    Hogie, Keith; Crisuolo, Ed; Parise, Ron

    2004-01-01

    This presentation will describe the design, development, and testing of a system to collect telemetry, format it into UDP/IP packets, and deliver it to a ground test range using standard IP technologies over a TDRSS link. This presentation will discuss the goal of the STARS IP Formatter along with the overall design. It will also present performance results of the current version of the IP formatter. Finally, it will discuss key issues for supporting constant rate telemetry data delivery when using standard components such as PCI/104 processors, the Linux operating system, Internet Protocols, and synchronous serial interfaces.

  11. 21 CFR 660.36 - Samples and protocols.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.36 Samples... a cell panel intended for identification of unexpected antibodies. The sample shall be packaged as... distribution of each lot of Reagent Red Blood Cells for detection or identification of unexpected antibodies...

  12. The Interlibrary Loan Protocol: An OSI Solution to ILL Messaging.

    ERIC Educational Resources Information Center

    Turner, Fay

    1990-01-01

    Discusses the interlibrary loan (ILL) protocol, a standard based on the principles of the Open Systems Interconnection (OSI) Reference Model. Benefits derived from protocol use are described, the status of the protocol as an international standard is reviewed, and steps taken by the National Library of Canada to facilitate migration to an ILL…

  13. A new display stream compression standard under development in VESA

    NASA Astrophysics Data System (ADS)

    Jacobson, Natan; Thirumalai, Vijayaraghavan; Joshi, Rajan; Goel, James

    2017-09-01

    The Advanced Display Stream Compression (ADSC) codec project is in development in response to a call for technologies from the Video Electronics Standards Association (VESA). This codec targets visually lossless compression of display streams at a high compression rate (typically 6 bits/pixel) for mobile/VR/HDR applications. Functionality of the ADSC codec is described in this paper, and subjective trials results are provided using the ISO 29170-2 testing protocol.

  14. Effect of adding one 15-minute-walk on the day of surgery to fast-track rehabilitation after total knee arthroplasty: a randomized, single-blind study.

    PubMed

    Zietek, P; Zietek, J; Szczypior, K; Safranow, K

    2015-06-01

    Earlier and more intensive physiotherapy exercise after total knee arthroplasty (TKA) enhance recovery, but the best combination of intensity and duration has not been determined. To determine whether adding a single, 15-minute walk on the day of surgery to a fast-track rehabilitation protocol would reduce knee pain and improve knee function after TKA. A randomized single-blind study. Inpatient. Patients with primary osteoarthrosis after TKA. Patients undergoing TKA were randomly assigned to a standard, fast-track rehabilitation protocol consisting of a single, 15-minute walk with a high-rolling walker 4 to 6 hours after recovery from spinal anesthesia or to an intensive protocol, in which patients took a second 15-minute walk at least 3 hours after the first, only on the day of surgery. Outcomes were pain measured on a visual analog scale, Knee Society's (KSS) clinical and functional scores, Oxford knee scores, and Spielberger State-Trait Anxiety Inventory scores. Patients were blinded to group assignment. Since most data were non-normally distributed non-parametric tests were used. Groups were compared with Mann-Whitney U test (for continuous variables). Association between continuous variables was evaluated with Spearman`s rank correlation coefficient. Chi-square or Fisher's exact test was used to assess differences in categorical variables. Of 86 patients assessed for eligibility, 66 were randomly assigned. The 31 evaluable patients on the intensive protocol (mean age, 68 years; 18 women) did not differ significantly from the 31 (mean age, 70 years; 20 women) on the standard protocol on any baseline characteristic or on any outcome measure on any day. On the second postoperative day, pain while walking dropped from a mean of 6.1 to a mean of 4.9 in the intensive group and from 6.4 to 5.4 in the standard group. Results for pain at rest were 3.3 to 2.2, respectively, for the intensive group and 4.0 to 3.0 for the standard group. At 2 weeks, pain at rest was 2.8 in both groups, and pain while walking was 3.0, respectively, for the intensive group and 3.4 for the standard group. At 2 weeks, mean (SD) KSS clinical and KSS function scores were, respectively, 74.9 (12.5) and 51.6 (16.2) in the intensive group and 71.2 (14.3) and 46.3 (16.1) in the standard group. Older age correlated with decreasing knee function (rS=-0.43, P<0.001), and less knee flexion correlated with preoperatively higher state anxiety (rS=-0.37, P=0.005) and trait anxiety (rS=-0.29, P=0.027). The study is limited by its small sample. The fast-track program was not in line with the best available evidence following knee arthroplasty, because patients did not undergo such treatment as NMES. Finally, the intervention itself was modest. Adding an additional 15-minute walk to a fast-track rehabilitation protocol did not increase pain, but neither did it improve functional recovery. A 15-minute walk immediately after recovery from spinal anesthesia did not increase pain in patients with TKA. More intense exercise during this period might improve functional recovery without increasing pain.

  15. An approach to standardization of urine sediment analysis via suggestion of a common manual protocol.

    PubMed

    Ko, Dae-Hyun; Ji, Misuk; Kim, Sollip; Cho, Eun-Jung; Lee, Woochang; Yun, Yeo-Min; Chun, Sail; Min, Won-Ki

    2016-01-01

    The results of urine sediment analysis have been reported semiquantitatively. However, as recent guidelines recommend quantitative reporting of urine sediment, and with the development of automated urine sediment analyzers, there is an increasing need for quantitative analysis of urine sediment. Here, we developed a protocol for urine sediment analysis and quantified the results. Based on questionnaires, various reports, guidelines, and experimental results, we developed a protocol for urine sediment analysis. The results of this new protocol were compared with those obtained with a standardized chamber and an automated sediment analyzer. Reference intervals were also estimated using new protocol. We developed a protocol with centrifugation at 400 g for 5 min, with the average concentration factor of 30. The correlation between quantitative results of urine sediment analysis, the standardized chamber, and the automated sediment analyzer were generally good. The conversion factor derived from the new protocol showed a better fit with the results of manual count than the default conversion factor in the automated sediment analyzer. We developed a protocol for manual urine sediment analysis to quantitatively report the results. This protocol may provide a mean for standardization of urine sediment analysis.

  16. Advanced Nanoindentation Testing for Studying Strain-Rate Sensitivity and Activation Volume

    NASA Astrophysics Data System (ADS)

    Maier-Kiener, Verena; Durst, Karsten

    2017-11-01

    Nanoindentation became a versatile tool for testing local mechanical properties beyond hardness and modulus. By adapting standard nanoindentation test methods, simple protocols capable of probing thermally activated deformation processes can be accomplished. Abrupt strain-rate changes within one indentation allow determining the strain-rate dependency of hardness at various indentation depths. For probing lower strain-rates and excluding thermal drift influences, long-term creep experiments can be performed by using the dynamic contact stiffness for determining the true contact area. From both procedures hardness and strain-rate, and consequently strain-rate sensitivity and activation volume can be reliably deducted within one indentation, permitting information on the locally acting thermally activated deformation mechanism. This review will first discuss various testing protocols including possible challenges and improvements. Second, it will focus on different examples showing the direct influence of crystal structure and/or microstructure on the underlying deformation behavior in pure and highly alloyed material systems.

  17. Validity of Assessments of Youth Access to Tobacco: The Familiarity Effect

    PubMed Central

    Landrine, Hope; Klonoff, Elizabeth A.

    2003-01-01

    Objectives. We examined the standard compliance protocol and its validity as a measure of youth access to tobacco. Methods. In Study 1, youth smokers reported buying cigarettes in stores where they are regular customers. In Study 2, youths attempted to purchase cigarettes by using the Standard Protocol, in which they appeared at stores once for cigarettes, and by using the Familiarity Protocol, in which they were rendered regular customers by purchasing nontobacco items 4 times and then requested cigarettes during their fifth visit. Results. Sales to youths aged 17 years in the Familiarity Protocol were significantly higher than sales to the same age group in the Standard Protocols (62.5% vs. 6%, respectively). Conclusions. The Standard Protocol does not match how youths obtain cigarettes. Access is low for stranger youths within compliance studies, but access is high for familiar youths outside of compliance studies. PMID:14600057

  18. Outcomes of Optimized over Standard Protocol of Rabbit Antithymocyte Globulin for Severe Aplastic Anemia: A Single-Center Experience

    PubMed Central

    Ge, Meili; Shao, Yingqi; Huang, Jinbo; Huang, Zhendong; Zhang, Jing; Nie, Neng; Zheng, Yizhou

    2013-01-01

    Background Previous reports showed that outcome of rabbit antithymocyte globulin (rATG) was not satisfactory as the first-line therapy for severe aplastic anemia (SAA). We explored a modifying schedule of administration of rATG. Design and Methods Outcomes of a cohort of 175 SAA patients, including 51 patients administered with standard protocol (3.55 mg/kg/d for 5 days) and 124 cases with optimized protocol (1.97 mg/kg/d for 9 days) of rATG plus cyclosporine (CSA), were analyzed retrospectively. Results Of all 175 patients, response rates at 3 and 6 months were 36.6% and 56.0%, respectively. 51 cases received standard protocol had poor responses at 3 (25.5%) and 6 months (41.2%). However, 124 patients received optimized protocol had better responses at 3 (41.1%, P = 0.14) and 6 (62.1%, P = 0.01). Higher incidences of infection (57.1% versus 37.9%, P = 0.02) and early mortality (17.9% versus 0.8%, P<0.001) occurred in patients received standard protocol compared with optimized protocol. The 5-year overall survival in favor of the optimized over standard rATG protocol (76.0% versus. 50.3%, P<0.001) was observed. By multivariate analysis, optimized protocol (RR = 2.21, P = 0.04), response at 3 months (RR = 10.31, P = 0.03) and shorter interval (<23 days) between diagnosis and initial dose of rATG (RR = 5.35, P = 0.002) were independent favorable predictors of overall survival. Conclusions Optimized instead of standard rATG protocol in combination with CSA remained efficacious as a first-line immunosuppressive regimen for SAA. PMID:23554855

  19. The effect of different methods and image analyzers on the results of the in vivo comet assay.

    PubMed

    Kyoya, Takahiro; Iwamoto, Rika; Shimanura, Yuko; Terada, Megumi; Masuda, Shuichi

    2018-01-01

    The in vivo comet assay is a widely used genotoxicity test that can detect DNA damage in a range of organs. It is included in the Organisation for Economic Co-operation and Development Guidelines for the Testing of Chemicals. However, various protocols are still used for this assay, and several different image analyzers are used routinely to evaluate the results. Here, we verified a protocol that largely contributes to the equivalence of results, and we assessed the effect on the results when slides made from the same sample were analyzed using two different image analyzers (Comet Assay IV vs Comet Analyzer). Standardizing the agarose concentrations and DNA unwinding and electrophoresis times had a large impact on the equivalence of the results between the different methods used for the in vivo comet assay. In addition, there was some variation in the sensitivity of the two different image analyzers tested; however this variation was considered to be minor and became negligible when the test conditions were standardized between the two different methods. By standardizing the concentrations of low melting agarose and DNA unwinding and electrophoresis times between both methods used in the current study, the sensitivity to detect the genotoxicity of a positive control substance in the in vivo comet assay became generally comparable, independently of the image analyzer used. However, there may still be the possibility that other conditions, except for the three described here, could affect the reproducibility of the in vivo comet assay.

  20. Validity and Reliability of Baseline Testing in a Standardized Environment.

    PubMed

    Higgins, Kathryn L; Caze, Todd; Maerlender, Arthur

    2017-08-11

    The Immediate Postconcussion Assessment and Cognitive Testing (ImPACT) is a computerized neuropsychological test battery commonly used to determine cognitive recovery from concussion based on comparing post-injury scores to baseline scores. This model is based on the premise that ImPACT baseline test scores are a valid and reliable measure of optimal cognitive function at baseline. Growing evidence suggests that this premise may not be accurate and a large contributor to invalid and unreliable baseline test scores may be the protocol and environment in which baseline tests are administered. This study examined the effects of a standardized environment and administration protocol on the reliability and performance validity of athletes' baseline test scores on ImPACT by comparing scores obtained in two different group-testing settings. Three hundred-sixty one Division 1 cohort-matched collegiate athletes' baseline data were assessed using a variety of indicators of potential performance invalidity; internal reliability was also examined. Thirty-one to thirty-nine percent of the baseline cases had at least one indicator of low performance validity, but there were no significant differences in validity indicators based on environment in which the testing was conducted. Internal consistency reliability scores were in the acceptable to good range, with no significant differences between administration conditions. These results suggest that athletes may be reliably performing at levels lower than their best effort would produce. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  1. Agreement between gastrointestinal panel testing and standard microbiology methods for detecting pathogens in suspected infectious gastroenteritis: Test evaluation and meta-analysis in the absence of a reference standard.

    PubMed

    Freeman, Karoline; Tsertsvadze, Alexander; Taylor-Phillips, Sian; McCarthy, Noel; Mistry, Hema; Manuel, Rohini; Mason, James

    2017-01-01

    Multiplex gastrointestinal pathogen panel (GPP) tests simultaneously identify bacterial, viral and parasitic pathogens from the stool samples of patients with suspected infectious gastroenteritis presenting in hospital or the community. We undertook a systematic review to compare the accuracy of GPP tests with standard microbiology techniques. Searches in Medline, Embase, Web of Science and the Cochrane library were undertaken from inception to January 2016. Eligible studies compared GPP tests with standard microbiology techniques in patients with suspected gastroenteritis. Quality assessment of included studies used tailored QUADAS-2. In the absence of a reference standard we analysed test performance taking GPP tests and standard microbiology techniques in turn as the benchmark test, using random effects meta-analysis of proportions. No study provided an adequate reference standard with which to compare the test accuracy of GPP and conventional tests. Ten studies informed a meta-analysis of positive and negative agreement. Positive agreement across all pathogens was 0.93 (95% CI 0.90 to 0.96) when conventional methods were the benchmark and 0.68 (95% CI: 0.58 to 0.77) when GPP provided the benchmark. Negative agreement was high in both instances due to the high proportion of negative cases. GPP testing produced a greater number of pathogen-positive findings than conventional testing. It is unclear whether these additional 'positives' are clinically important. GPP testing has the potential to simplify testing and accelerate reporting when compared to conventional microbiology methods. However the impact of GPP testing upon the management, treatment and outcome of patients is poorly understood and further studies are needed to evaluate the health economic impact of GPP testing compared with standard methods. The review protocol is registered with PROSPERO as CRD42016033320.

  2. Natural Language Processing–Enabled and Conventional Data Capture Methods for Input to Electronic Health Records: A Comparative Usability Study

    PubMed Central

    Sheehan, Barbara; Stetson, Peter; Bhatt, Ashish R; Field, Adele I; Patel, Chirag; Maisel, James Mark

    2016-01-01

    Background The process of documentation in electronic health records (EHRs) is known to be time consuming, inefficient, and cumbersome. The use of dictation coupled with manual transcription has become an increasingly common practice. In recent years, natural language processing (NLP)–enabled data capture has become a viable alternative for data entry. It enables the clinician to maintain control of the process and potentially reduce the documentation burden. The question remains how this NLP-enabled workflow will impact EHR usability and whether it can meet the structured data and other EHR requirements while enhancing the user’s experience. Objective The objective of this study is evaluate the comparative effectiveness of an NLP-enabled data capture method using dictation and data extraction from transcribed documents (NLP Entry) in terms of documentation time, documentation quality, and usability versus standard EHR keyboard-and-mouse data entry. Methods This formative study investigated the results of using 4 combinations of NLP Entry and Standard Entry methods (“protocols”) of EHR data capture. We compared a novel dictation-based protocol using MediSapien NLP (NLP-NLP) for structured data capture against a standard structured data capture protocol (Standard-Standard) as well as 2 novel hybrid protocols (NLP-Standard and Standard-NLP). The 31 participants included neurologists, cardiologists, and nephrologists. Participants generated 4 consultation or admission notes using 4 documentation protocols. We recorded the time on task, documentation quality (using the Physician Documentation Quality Instrument, PDQI-9), and usability of the documentation processes. Results A total of 118 notes were documented across the 3 subject areas. The NLP-NLP protocol required a median of 5.2 minutes per cardiology note, 7.3 minutes per nephrology note, and 8.5 minutes per neurology note compared with 16.9, 20.7, and 21.2 minutes, respectively, using the Standard-Standard protocol and 13.8, 21.3, and 18.7 minutes using the Standard-NLP protocol (1 of 2 hybrid methods). Using 8 out of 9 characteristics measured by the PDQI-9 instrument, the NLP-NLP protocol received a median quality score sum of 24.5; the Standard-Standard protocol received a median sum of 29; and the Standard-NLP protocol received a median sum of 29.5. The mean total score of the usability measure was 36.7 when the participants used the NLP-NLP protocol compared with 30.3 when they used the Standard-Standard protocol. Conclusions In this study, the feasibility of an approach to EHR data capture involving the application of NLP to transcribed dictation was demonstrated. This novel dictation-based approach has the potential to reduce the time required for documentation and improve usability while maintaining documentation quality. Future research will evaluate the NLP-based EHR data capture approach in a clinical setting. It is reasonable to assert that EHRs will increasingly use NLP-enabled data entry tools such as MediSapien NLP because they hold promise for enhancing the documentation process and end-user experience. PMID:27793791

  3. Londrina Activities of Daily Living Protocol: Reproducibility, Validity, and Reference Values in Physically Independent Adults Age 50 Years and Older.

    PubMed

    Paes, Thaís; Belo, Letícia Fernandes; da Silva, Diego Rodrigues; Morita, Andrea Akemi; Donária, Leila; Furlanetto, Karina Couto; Sant'Anna, Thaís; Pitta, Fabio; Hernandes, Nidia Aparecida

    2017-03-01

    It is important to assess activities of daily living (ADL) in older adults due to impairment of independence and quality of life. However, there is no objective and standardized protocol available to assess this outcome. Thus, the aim of this study was to verify the reproducibility and validity of a new protocol for ADL assessment applied in physically independent adults age ≥50 y, the Londrina ADL protocol, and to establish an equation to predict reference values of the Londrina ADL protocol. Ninety-three physically independent adults age ≥50 y had their performance in ADL evaluated by registering the time spent to conclude the protocol. The protocol was performed twice. The 6-min walk test, which assesses functional exercise capacity, was used as a validation criterion. A multiple linear regression model was applied, including anthropometric and demographic variables that correlated with the protocol, to establish an equation to predict the protocol's reference values. In general, the protocol was reproducible (intraclass correlation coefficient 0.91). The average difference between the first and second protocol was 5.3%. The new protocol was valid to assess ADL performance in the studied subjects, presenting a moderate correlation with the 6-min walk test (r = -0.53). The time spent to perform the protocol correlated significantly with age (r = 0.45) but neither with weight (r = -0.17) nor with height (r = -0.17). A model of stepwise multiple regression including sex and age showed that age was the only determinant factor to the Londrina ADL protocol, explaining 21% ( P < .001) of its variability. The derived reference equation was: Londrina ADL protocol pred (s) = 135.618 + (3.102 × age [y]). The Londrina ADL protocol was reproducible and valid in physically independent adults age ≥50 y. A reference equation for the protocol was established including only age as an independent variable (r 2 = 0.21), allowing a better interpretation of the protocol's results in clinical practice. Copyright © 2017 by Daedalus Enterprises.

  4. A biochemical protocol for the isolation and identification of current species of Vibrio in seafood.

    PubMed

    Ottaviani, D; Masini, L; Bacchiocchi, S

    2003-01-01

    We report a biochemical method for the isolation and identification of the current species of vibrios using just one operative protocol. The method involves an enrichment phase with incubation at 30 degrees C for 8-24 h in alkaline peptone water and an isolation phase on thiosulphate-citrate-salt sucrose agar plates incubating at 30 degrees C for 24 h. Four biochemical tests and Alsina's scheme were performed for genus and species identification, respectively. All biochemical tests were optimized as regards conditions of temperature, time of incubation and media composition. The whole standardized protocol was always able to give a correct identification when applied to 25 reference strains of Vibrio and 134 field isolates. The data demonstrated that the assay method allows an efficient recovery, isolation and identification of current species of Vibrio in seafood obtaining results within 2-7 days. This method based on biochemical tests could be applicable even in basic microbiology laboratories, and can be used simultaneously to isolate and discriminate all clinically relevant species of Vibrio.

  5. Older drivers: On-road and off-road test results.

    PubMed

    Selander, Helena; Lee, Hoe C; Johansson, Kurt; Falkmer, Torbjörn

    2011-07-01

    Eighty-five volunteer drivers, 65-85 years old, without cognitive impairments impacting on their driving were examined, in order to investigate driving errors characteristic for older drivers. In addition, any relationships between cognitive off-road and on-road tests results, the latter being the gold standard, were identified. Performance measurements included Trail Making Test (TMT), Nordic Stroke Driver Screening Assessment (NorSDSA), Useful Field of View (UFOV), self-rating driving performance and the two on-road protocols P-Drive and ROA. Some of the older drivers displayed questionable driving behaviour. In total, 21% of the participants failed the on-road assessment. Some of the specific errors were more serious than others. The most common driving errors embraced speed; exceeding the speed limit or not controlling the speed. Correlations with the P-Drive protocol were established for NorSDSA total score (weak), UFOV subtest 2 (weak), and UFOV subtest 3 (moderate). Correlations with the ROA protocol were established for UFOV subtest 2 (weak) and UFOV subtest 3 (weak). P-Drive and self ratings correlated weakly, whereas no correlation between self ratings and the ROA protocol was found. The results suggest that specific problems or errors seen in an older person's driving can actually be "normal driving behaviours". Copyright © 2011 Elsevier Ltd. All rights reserved.

  6. The international experience of bacterial screen testing of platelet components with an automated microbial detection system: a need for consensus testing and reporting guidelines.

    PubMed

    Benjamin, Richard J; McDonald, Carl P

    2014-04-01

    The BacT/ALERT microbial detection system (bioMerieux, Inc, Durham, NC) is in routine use in many blood centers as a prerelease test for platelet collections. Published reports document wide variation in practices and outcomes. A systematic review of the English literature was performed to describe publications assessing the use of the BacT/ALERT culture system on platelet collections as a routine screen test of more than 10000 platelet components. Sixteen publications report the use of confirmatory testing to substantiate initial positive culture results but use varying nomenclature to classify the results. Preanalytical and analytical variables that may affect the outcomes differ widely between centers. Incomplete description of protocol details complicates comparison between sites. Initial positive culture results range from 539 to 10606 per million (0.054%-1.061%) and confirmed positive from 127 to 1035 per million (0.013%-0.104%) donations. False-negative results determined by outdate culture range from 662 to 2173 per million (0.066%-0.217%) and by septic reactions from 0 to 66 per million (0%-0.007%) collections. Current culture protocols represent pragmatic compromises between optimizing analytical sensitivity and ensuring the timely availability of platelets for clinical needs. Insights into the effect of protocol variations on outcomes are generally restricted to individual sites that implement limited changes to their protocols over time. Platelet manufacturers should reassess the adequacy of their BacT/ALERT screening protocols in light of the growing international experience and provide detailed documentation of all variables that may affect culture outcomes when reporting results. We propose a framework for a standardized nomenclature for reporting of the results of BacT/ALERT screening. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. High sensitivity Troponin T: an audit of implementation of its protocol in a district general hospital.

    PubMed

    Kalim, Shahid; Nazir, Shaista; Khan, Zia Ullah

    2013-01-01

    Protocols based on newer high sensitivity Troponin T (hsTropT) assays can rule in a suspected Acute Myocardial Infarction (AMI) as early as 3 hours. We conducted this study to audit adherence to our Trust's newly introduced AMI diagnostic protocol based on paired hsTropT testing at 0 and 3 hours. We retrospectively reviewed data of all patients who had hsTropT test done between 1st and 7th May 2012. Patient's demographics, utility of single or paired samples, time interval between paired samples, patient's presenting symptoms and ECG findings were noted and their means, medians, Standard deviations and proportions were calculated. A total of 66 patients had hsTropT test done during this period. Mean age was 63.30 +/- 17.46 years and 38 (57.57%) were males. Twenty-four (36.36%) patients had only single, rather than protocol recommended paired hsTropT samples, taken. Among the 42 (63.63%) patients with paired samples, the mean time interval was found to be 4.41 +/- 5.7 hours. Contrary to the recommendations, 15 (22.73%) had a very long whereas 2 (3.03%) had a very short time interval between two samples. A subgroup analysis of patients with single samples, found only 2 (3.03%) patient with ST-segment elevation, appropriate for single testing. Our study confirmed that in a large number of patients the protocol for paired sampling or a recommended time interval of 3 hours between 2 samples was not being followed.

  8. Effects of a Delphi consensus acupuncture treatment protocol on the levels of stress and vascular tone in women undergoing in-vitro fertilization: a randomized clinical trial protocol.

    PubMed

    Zhang, Yan; Phy, Jennifer; Scott-Johnson, Chris; Garos, Sheila; Orlando, Jennie; Prien, Samuel; Huang, Jaou-Chen

    2017-04-04

    The variability of published acupuncture protocols for patients undergoing In-Vitro Fertilization (IVF) complicates the interpretation of data and hinders our understanding of acupuncture's impact. In 2012, an acupuncture treatment protocol developed by a Delphi consensus process was published to describe the parameters of best practice acupuncture for Assisted Reproductive Technology and future research. However, there has been no clinical trial utilizing this protocol to assess the effects of acupuncture. This study aims to assess the implementation of Dephi consensus acupuncture protocol and to examine the impact of acupuncture on stress and uterine and ovarian blood flow among women between ages 21-42 years seeking IVF. This study is a one site prospective, two-arm randomized controlled non-blind clinical trial conducted in a medical school-affiliated fertility center . Participants will be randomized 1:1 into either the acupuncture group or the standard of care (no acupuncture) group using computer generated tables. Both groups will have 3 regular clinical visits as their standard IVF care during an approximately 2 to 3 weeks window. Women who are randomized into the acupuncture group would receive three sessions based on the Delphi consensus acupuncture protocol in addition to the standard care. The first treatment will be administered between days 6 to 8 of the stimulated IVF cycle. The second session will be performed on the day of embryo transfer at least 1 h prior to the transfer. The third session will be performed within 48 h post-embryo transfer. Participants will be followed for their pregnancy test and pregnancy outcome when applicable. The outcomes stress and blood flow will be measured by a validated perceived stress scale and vasoactive molecules, respectively. Although recruitment and scheduling could be challenging at times, the Delphi consensus acupuncture protocol was implemented as planned and well-accepted by the patients. Because of the time-specified sessions around patients' IVF cycle, it is highly recommended to have on-site study acupuncturist(s) to accommodate the schedule. ClinicalTrials NCT02591186 registered on October 7, 2015.

  9. Interoperability in the Planetary Science Archive (PSA)

    NASA Astrophysics Data System (ADS)

    Rios Diaz, C.

    2017-09-01

    The protocols and standards currently being supported by the recently released new version of the Planetary Science Archive at this time are the Planetary Data Access Protocol (PDAP), the EuroPlanet- Table Access Protocol (EPN-TAP) and Open Geospatial Consortium (OGC) standards. We explore these protocols in more detail providing scientifically useful examples of their usage within the PSA.

  10. 10 CFR 712.38 - Maintenance of medical records.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Maintenance of medical records. 712.38 Section 712.38 Energy DEPARTMENT OF ENERGY HUMAN RELIABILITY PROGRAM Medical Standards § 712.38 Maintenance of medical... medical record. The psychological record must: (1) Contain any clinical reports, test protocols and data...

  11. Protocol Analysis of Aptitude Differences in Figural Analogy Problem Representation.

    ERIC Educational Resources Information Center

    Schiano, Diane J.

    Individual differences in performance on figural analogy tests are usually attributed to quantitative differences in processing parameters rather than to qualitative differences in the formation and use of representations. Yet aptitude-related differences in categorizing standardized figural analogy problems between high and low scorers have been…

  12. Assessing transportation infrastructure impacts on rangelands: Test of a standard rangeland assessment protocol

    USDA-ARS?s Scientific Manuscript database

    Linear disturbances associated with on and off-road vehicle use on rangelands has increased dramatically throughout the world in recent decades. This increase is due to a variety of factors including increased availability of all-terrain vehicles, infrastructure development (oil, gas, renewable ene...

  13. 75 FR 26842 - Petition for Waiver of Compliance

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-12

    ... testing protocol of the Locomotive Safety Standards, 49 CFR 229.129(c), as it pertains to railroad... writing, before the end of the comment period and specify the basis for their request. All communications.... and 5 p.m., Monday through Friday, except Federal holidays. Communications received within 45 days of...

  14. Building Capacity for a Long-Term, in-Situ, National-Scale Phenology Monitoring Network: Successes, Challenges and Lessons Learned

    NASA Astrophysics Data System (ADS)

    Weltzin, J. F.; Browning, D. M.

    2014-12-01

    The USA National Phenology Network (USA-NPN; www.usanpn.org) is a national-scale science and monitoring initiative focused on phenology - the study of seasonal life-cycle events such as leafing, flowering, reproduction, and migration - as a tool to understand the response of biodiversity to environmental variation and change. USA-NPN provides a hierarchical, national monitoring framework that enables other organizations to leverage the capacity of the Network for their own applications - minimizing investment and duplication of effort - while promoting interoperability. Network participants can leverage: (1) Standardized monitoring protocols that have been broadly vetted, tested and published; (2) A centralized National Phenology Database (NPDb) for maintaining, archiving and replicating data, with standard metadata, terms-of-use, web-services, and documentation of QA/QC, plus tools for discovery, visualization and download of raw data and derived data products; and/or (3) A national in-situ, multi-taxa phenological monitoring system, Nature's Notebook, which enables participants to observe and record phenology of plants and animals - based on the protocols and information management system (IMS) described above - via either web or mobile applications. The protocols, NPDb and IMS, and Nature's Notebook represent a hierarchy of opportunities for involvement by a broad range of interested stakeholders, from individuals to agencies. For example, some organizations have adopted (e.g., the National Ecological Observatory Network or NEON) -- or are considering adopting (e.g., the Long-Term Agroecosystems Network or LTAR) -- the USA-NPN standardized protocols, but will develop their own database and IMS with web services to promote sharing of data with the NPDb. Other organizations (e.g., the Inventory and Monitoring Programs of the National Wildlife Refuge System and the National Park Service) have elected to use Nature's Notebook to support their phenological monitoring programs. We highlight the challenges and benefits of integrating phenology monitoring within existing and emerging national monitoring networks, and showcase opportunities that exist when standardized protocols are adopted and implemented to promote data interoperability and sharing.

  15. Model-based Iterative Reconstruction: Effect on Patient Radiation Dose and Image Quality in Pediatric Body CT

    PubMed Central

    Dillman, Jonathan R.; Goodsitt, Mitchell M.; Christodoulou, Emmanuel G.; Keshavarzi, Nahid; Strouse, Peter J.

    2014-01-01

    Purpose To retrospectively compare image quality and radiation dose between a reduced-dose computed tomographic (CT) protocol that uses model-based iterative reconstruction (MBIR) and a standard-dose CT protocol that uses 30% adaptive statistical iterative reconstruction (ASIR) with filtered back projection. Materials and Methods Institutional review board approval was obtained. Clinical CT images of the chest, abdomen, and pelvis obtained with a reduced-dose protocol were identified. Images were reconstructed with two algorithms: MBIR and 100% ASIR. All subjects had undergone standard-dose CT within the prior year, and the images were reconstructed with 30% ASIR. Reduced- and standard-dose images were evaluated objectively and subjectively. Reduced-dose images were evaluated for lesion detectability. Spatial resolution was assessed in a phantom. Radiation dose was estimated by using volumetric CT dose index (CTDIvol) and calculated size-specific dose estimates (SSDE). A combination of descriptive statistics, analysis of variance, and t tests was used for statistical analysis. Results In the 25 patients who underwent the reduced-dose protocol, mean decrease in CTDIvol was 46% (range, 19%–65%) and mean decrease in SSDE was 44% (range, 19%–64%). Reduced-dose MBIR images had less noise (P > .004). Spatial resolution was superior for reduced-dose MBIR images. Reduced-dose MBIR images were equivalent to standard-dose images for lungs and soft tissues (P > .05) but were inferior for bones (P = .004). Reduced-dose 100% ASIR images were inferior for soft tissues (P < .002), lungs (P < .001), and bones (P < .001). By using the same reduced-dose acquisition, lesion detectability was better (38% [32 of 84 rated lesions]) or the same (62% [52 of 84 rated lesions]) with MBIR as compared with 100% ASIR. Conclusion CT performed with a reduced-dose protocol and MBIR is feasible in the pediatric population, and it maintains diagnostic quality. © RSNA, 2013 Online supplemental material is available for this article. PMID:24091359

  16. One Approach for Transitioning the iNET Standards into the IRIG 106 Telemetry Standards

    DTIC Science & Technology

    2015-05-26

    Protocol Suite. Figure 1 illustrates the Open Systems Interconnection ( OSI ) Model, the corresponding TCP/IP Model, and the major components of the TCP...IP Protocol Suite. Figure 2 represents the iNET-specific protocols layered onto the TCP/IP Model. Figure 1. OSI and TCP/IP Model with TCP/IP...Protocol Suite TCP/IP Protocol Suite Major Components IPv4 IPv6 TCP/IP Model OSI Model Application Presentation

  17. STANDARD MEASUREMENT PROTOCOLS - FLORIDA RADON RESEARCH PROGRAM

    EPA Science Inventory

    The manual, in support of the Florida Radon Research Program, contains standard protocols for key measurements where data quality is vital to the program. t contains two sections. he first section, soil measurements, contains field sampling protocols for soil gas permeability and...

  18. A time and imaging cost analysis of low-risk ED observation patients: a conservative 64-section computed tomography coronary angiography "triple rule-out" compared to nuclear stress test strategy.

    PubMed

    Takakuwa, Kevin M; Halpern, Ethan J; Shofer, Frances S

    2011-02-01

    The study aimed to examine time and imaging costs of 2 different imaging strategies for low-risk emergency department (ED) observation patients with acute chest pain or symptoms suggestive of acute coronary syndrome. We compared a "triple rule-out" (TRO) 64-section multidetector computed tomography protocol with nuclear stress testing. This was a prospective observational cohort study of consecutive ED patients who were enrolled in our chest pain observation protocol during a 16-month period. Our standard observation protocol included a minimum of 2 sets of cardiac enzymes at least 6 hours apart followed by a nuclear stress test. Once a week, observation patients were offered a TRO (to evaluate for coronary artery disease, thoracic dissection, and pulmonary embolus) multidetector computed tomography with the option of further stress testing for those patients found to have evidence of coronary artery disease. We analyzed 832 consecutive observation patients including 214 patients who underwent the TRO protocol. Mean total length of stay was 16.1 hours for TRO patients, 16.3 hours for TRO plus other imaging test, 22.6 hours for nuclear stress testing, 23.3 hours for nuclear stress testing plus other imaging tests, and 23.7 hours for nuclear stress testing plus TRO (P < .0001 for TRO and TRO + other test compared to stress test ± other test). Mean imaging times were 3.6, 4.4, 5.9, 7.5, and 6.6 hours, respectively (P < .05 for TRO and TRO + other test compared to stress test ± other test). Mean imaging costs were $1307 for TRO patients vs $945 for nuclear stress testing. Triple rule-out reduced total length of stay and imaging time but incurred higher imaging costs. A per-hospital analysis would be needed to determine if patient time savings justify the higher imaging costs. Copyright © 2011 Elsevier Inc. All rights reserved.

  19. [Fewer caesarean sections for breech presentation following external cephalic version according to a protocol in a special office visit].

    PubMed

    Kuppens, S M I; Hasaart, T H M; van der Donk, M W P; Huibers, M; Franssen, M J; de Becker, B M J; Wijnen, H A A; Pop, V J M

    2008-06-07

    Identification of determinants affecting the outcome of external cephalic version (ECV) in breech presentation, and investigation of the impact of ECV--performed according to a standardized protocol in an outpatient clinic--on the mode of delivery. Retrospective analysis. In 2003 a standardized protocol of ECV was developed in the outpatient clinic for obstetrics of the Catharina Hospital in Eindhoven, the Netherlands; it was tested in 'version office visits'. Obstetric characteristics of all pregnant women who underwent attempts of ECV in the clinic from January 2004 until June 2006 during these sessions, and the subsequent births, were analysed. 85% of all ECVs were performed by the same hospital midwife and gynaecologist, in accordance with the protocol. ECV was successful in 96 of 209 pregnant women (46%). In 1 pregnant woman an emergency caesarean section was performed after ECV because of partial abruptio placentae. Nulliparity, incomplete breech presentation and low birth weight of the baby were associated with a lower success rate of ECV in this study. In the group with a successful ECV the percentage of caesarean deliveries was substantially lower (9 versus 83%; odds ratio: 0.21; 95% CI: 0.09-0.51). A regular team consisting of a hospital midwife and a gynaecologist working according to a standardized protocol for ECV in a case of breech presentation proved successful: the number of term breech presentations substantially diminished and therefore the percentage of caesarean sections was lower in the group in which ECV had been successful. This could have considerable impact on health care in the Netherlands in terms of reduced maternal morbidity and cost savings.

  20. Developing the Fourth Evaluation Dimension: A Protocol for Evaluation of Video From the Patient's Perspective During Major Incident Exercises.

    PubMed

    Haverkort, J J Mark; Leenen, Luke P H

    2017-10-01

    Presently used evaluation techniques rely on 3 traditional dimensions: reports from observers, registration system data, and observational cameras. Some of these techniques are observer-dependent and are not reproducible for a second review. This proof-of-concept study aimed to test the feasibility of extending evaluation to a fourth dimension, the patient's perspective. Footage was obtained during a large, full-scale hospital trauma drill. Two mock victims were equipped with point-of-view cameras filming from the patient's head. Based on the Major Incident Hospital's first experience during the drill, a protocol was developed for a prospective, standardized method to evaluate a hospital's major incident response from the patient's perspective. The protocol was then tested in a second drill for its feasibility. New insights were gained after review of the footage. The traditional observer missed some of the evaluation points, which were seen on the point-of-view cameras. The information gained from the patient's perspective proved to be implementable into the designed protocol. Use of point-of-view camera recordings from a mock patient's perspective is a valuable addition to traditional evaluation of trauma drills and trauma care. Protocols should be designed to optimize and objectify judgement of such footage. (Disaster Med Public Health Preparedness. 2017;11:594-599).

  1. Developmental toxicity, acute toxicity and mutagenicity testing in freshwater snails Biomphalaria glabrata (Mollusca: Gastropoda) exposed to chromium and water samples.

    PubMed

    Tallarico, Lenita de Freitas; Borrely, Sueli Ivone; Hamada, Natália; Grazeffe, Vanessa Siqueira; Ohlweiler, Fernanda Pires; Okazaki, Kayo; Granatelli, Amanda Tosatte; Pereira, Ivana Wuo; Pereira, Carlos Alberto de Bragança; Nakano, Eliana

    2014-12-01

    A protocol combining acute toxicity, developmental toxicity and mutagenicity analysis in freshwater snail Biomphalaria glabrata for application in ecotoxicological studies is described. For acute toxicity testing, LC50 and EC50 values were determined; dominant lethal mutations induction was the endpoint for mutagenicity analysis. Reference toxicant potassium dichromate (K2Cr2O7) was used to characterize B. glabrata sensitivity for toxicity and cyclophosphamide to mutagenicity testing purposes. Compared to other relevant freshwater species, B. glabrata showed high sensitivity: the lowest EC50 value was obtained with embryos at veliger stage (5.76mg/L). To assess the model applicability for environmental studies, influent and effluent water samples from a wastewater treatment plant were evaluated. Gastropod sensitivity was assessed in comparison to the standardized bioassay with Daphnia similis exposed to the same water samples. Sampling sites identified as toxic to daphnids were also detected by snails, showing a qualitatively similar sensitivity suggesting that B. glabrata is a suitable test species for freshwater monitoring. Holding procedures and protocols implemented for toxicity and developmental bioassays showed to be in compliance with international standards for intra-laboratory precision. Thereby, we are proposing this system for application in ecotoxicological studies. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. On shaky ground - A study of security vulnerabilities in control protocols

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Byres, E. J.; Huffman, D.; Kube, N.

    2006-07-01

    The recent introduction of information technologies such as Ethernet R into nuclear industry control devices has resulted in significantly less isolation from the outside world. This raises the question of whether these systems could be attacked by malware, network hackers or professional criminals to cause disruption to critical operations in a manner similar to the impacts now felt in the business world. To help answer this question, a study was undertaken to test a representative control protocol to determine if it had vulnerabilities that could be exploited. A framework was created in which a test could express a large numbermore » of test cases in very compact formal language. This in turn, allowed for the economical automation of both the generation of selectively malformed protocol traffic and the measurement of device under test's (DUT) behavior in response to this traffic. Approximately 5000 protocol conformance tests were run against two major brands of industrial controller. More than 60 categories of errors were discovered, the majority of which were in the form of incorrect error responses to malformed traffic. Several malformed packets however, caused the device to respond or communicate in inappropriate ways. These would be relatively simple for an attacker to inject into a system and could result in the plant operator losing complete view or control of the control device. Based on this relatively small set of devices, we believe that the nuclear industry urgently needs to adopt better security robustness testing of control devices as standard practice. (authors)« less

  3. Evaluation of Protocol Uniformity Concerning Laparoscopic Cholecystectomy in The Netherlands

    PubMed Central

    Goossens, Richard H. M.; van Eijk, Daan J.; Lange, Johan F.

    2008-01-01

    Background Iatrogenic bile duct injury remains a current complication of laparoscopic cholecystectomy. One uniform and standardized protocol, based on the “critical view of safety” concept of Strasberg, should reduce the incidence of this complication. Furthermore, owing to the rapid development of minimally invasive surgery, technicians are becoming more frequently involved. To improve communication between the operating team and technicians, standardized actions should also be defined. The aim of this study was to compare existing protocols for laparoscopic cholecystectomy from various Dutch hospitals. Methods Fifteen Dutch hospitals were contacted for evaluation of their protocols for laparoscopic cholecystectomy. All evaluated protocols were divided into six steps and were compared accordingly. Results In total, 13 hospitals responded—5 academic hospitals, 5 teaching hospitals, 3 community hospitals—of which 10 protocols were usable for comparison. Concerning the trocar positions, only minor differences were found. The concept of “critical view of safety” was represented in just one protocol. Furthermore, the order of clipping and cutting the cystic artery and duct differed. Descriptions of instruments and apparatus were also inconsistent. Conclusions Present protocols differ too much to define a universal procedure among surgeons in The Netherlands. The authors propose one (inter)national standardized protocol, including standardized actions. This uniform standardized protocol has to be officially released and recommended by national scientific associations (e.g., the Dutch Society of Surgery) or international societies (e.g., European Association for Endoscopic Surgery and Society of American Gastrointestinal and Endoscopic Surgeons). The aim is to improve patient safety and professional communication, which are necessary for new developments. PMID:18224485

  4. Leveraging the trusted clinician: documenting disease management program enrollment.

    PubMed

    Frazee, Sharon Glave; Kirkpatrick, Patricia; Fabius, Raymond; Chimera, Joseph

    2007-02-01

    The objective of this study was to test the hypothesis that an integrated disease management (IDM) protocol (patent-pending), which combines telephonic-delivered disease management (TDM) with a worksite-based primary care center and pharmacy delivery, would yield higher contact and enrollment rates than traditional remote disease management alone. IDM is characterized by the combination of standard TDM with a worksite-based primary care and pharmacy delivery protocol led by trusted clinicians. This prospective cohort study tracks contact and enrollment rates for persons assigned to either IDM or traditional TDM protocols, and compares them on contact and enrollment efficiency. The IDM protocol showed a significant improvement in contact and enrollment rates over traditional TDM. Integrating a worksite-based primary care and pharmacy delivery system led by trusted clinicians with traditional TDM increases contact and enrollment rates, resulting in higher patient engagement. The IDM protocol should be adopted by employers seeking higher returns on their investment in disease management programming.

  5. Measuring bioenergetics in T cells using a Seahorse Extracellular Flux Analyzer

    PubMed Central

    van der Windt, Gerritje J.W.; Chang, Chih-Hao; Pearce, Erika L.

    2016-01-01

    This unit contains several protocols to determine the energy utilization of T cells in real-time using a Seahorse Extracellular Flux Analyzer (www.seahorsebio.com). The advantages to using this machine over traditional metabolic assays include the simultaneous measurement of glycolysis and mitochondrial respiration, in real-time, on relatively small numbers of cells, without any radioactivity. The Basic Protocol describes a standard mitochondrial stress test on the XFe96, which yields information about oxidative phosphorylation and glycolysis, two energy-generating pathways. The alternate protocols provide examples of adaptations to the Basic Protocol, including adjustments for the use of the XFe24. A protocol for real-time bioenergetic responses to T cell activation allows for the analysis of immediate metabolic changes after T cell receptor stimulation. Specific substrate utilization can be determined by the use of differential assay media, or the injection of drugs that specifically affect certain metabolic processes. Accurate cell numbers, purity, and viability are critical to obtain reliable results. PMID:27038461

  6. Measuring Bioenergetics in T Cells Using a Seahorse Extracellular Flux Analyzer.

    PubMed

    van der Windt, Gerritje J W; Chang, Chih-Hao; Pearce, Erika L

    2016-04-01

    This unit contains several protocols to determine the energy utilization of T cells in real-time using a Seahorse Extracellular Flux Analyzer (http://www.seahorsebio.com). The advantages to using this machine over traditional metabolic assays include the simultaneous measurement of glycolysis and mitochondrial respiration, in real-time, on relatively small numbers of cells, without any radioactivity. The Basic Protocol describes a standard mitochondrial stress test on the XF(e) 96, which yields information about oxidative phosphorylation and glycolysis, two energy-generating pathways. The alternate protocols provide examples of adaptations to the Basic Protocol, including adjustments for the use of the XF(e) 24. A protocol for real-time bioenergetic responses to T cell activation allows for the analysis of immediate metabolic changes after T cell receptor stimulation. Specific substrate utilization can be determined by the use of differential assay media, or the injection of drugs that specifically affect certain metabolic processes. Accurate cell numbers, purity, and viability are critical to obtain reliable results. Copyright © 2016 John Wiley & Sons, Inc.

  7. Baseline Assessment of 25-Hydroxyvitamin D Reference Material and Proficiency Testing/External Quality Assurance Material Commutability: A Vitamin D Standardization Program Study.

    PubMed

    Phinney, Karen W; Sempos, Christopher T; Tai, Susan S-C; Camara, Johanna E; Wise, Stephen A; Eckfeldt, John H; Hoofnagle, Andrew N; Carter, Graham D; Jones, Julia; Myers, Gary L; Durazo-Arvizu, Ramon; Miller, W Greg; Bachmann, Lorin M; Young, Ian S; Pettit, Juanita; Caldwell, Grahame; Liu, Andrew; Brooks, Stephen P J; Sarafin, Kurtis; Thamm, Michael; Mensink, Gert B M; Busch, Markus; Rabenberg, Martina; Cashman, Kevin D; Kiely, Mairead; Galvin, Karen; Zhang, Joy Y; Kinsella, Michael; Oh, Kyungwon; Lee, Sun-Wha; Jung, Chae L; Cox, Lorna; Goldberg, Gail; Guberg, Kate; Meadows, Sarah; Prentice, Ann; Tian, Lu; Brannon, Patsy M; Lucas, Robyn M; Crump, Peter M; Cavalier, Etienne; Merkel, Joyce; Betz, Joseph M

    2017-09-01

    The Vitamin D Standardization Program (VDSP) coordinated a study in 2012 to assess the commutability of reference materials and proficiency testing/external quality assurance materials for total 25-hydroxyvitamin D [25(OH)D] in human serum, the primary indicator of vitamin D status. A set of 50 single-donor serum samples as well as 17 reference and proficiency testing/external quality assessment materials were analyzed by participating laboratories that used either immunoassay or LC-MS methods for total 25(OH)D. The commutability test materials included National Institute of Standards and Technology Standard Reference Material 972a Vitamin D Metabolites in Human Serum as well as materials from the College of American Pathologists and the Vitamin D External Quality Assessment Scheme. Study protocols and data analysis procedures were in accordance with Clinical and Laboratory Standards Institute guidelines. The majority of the test materials were found to be commutable with the methods used in this commutability study. These results provide guidance for laboratories needing to choose appropriate reference materials and select proficiency or external quality assessment programs and will serve as a foundation for additional VDSP studies.

  8. Effects of standard training in the use of closed-circuit televisions in visually impaired adults: design of a training protocol and a randomized controlled trial.

    PubMed

    Burggraaff, Marloes C; van Nispen, Ruth M A; Melis-Dankers, Bart J M; van Rens, Ger H M B

    2010-03-10

    Reading problems are frequently reported by visually impaired persons. A closed-circuit television (CCTV) can be helpful to maintain reading ability, however, it is difficult to learn how to use this device. In the Netherlands, an evidence-based rehabilitation program in the use of CCTVs was lacking. Therefore, a standard training protocol needed to be developed and tested in a randomized controlled trial (RCT) to provide an evidence-based training program in the use of this device. To develop a standard training program, information was collected by studying literature, observing training in the use of CCTVs, discussing the content of the training program with professionals and organizing focus and discussion groups. The effectiveness of the program was evaluated in an RCT, to obtain an evidence-based training program. Dutch patients (n = 122) were randomized into a treatment group: normal instructions from the supplier combined with training in the use of CCTVs, or into a control group: instructions from the supplier only. The effect of the training program was evaluated in terms of: change in reading ability (reading speed and reading comprehension), patients' skills to operate the CCTV, perceived (vision-related) quality of life and tasks performed in daily living. The development of the CCTV training protocol and the design of the RCT in the present study may serve as an example to obtain an evidence-based training program. The training program was adjusted to the needs and learning abilities of individual patients, however, for scientific reasons it might have been preferable to standardize the protocol further, in order to gain more comparable results. http://www.trialregister.nl, identifier: NTR1031.

  9. Permeability Surface Area Product Using Perfusion Computed Tomography Is a Valuable Prognostic Factor in Glioblastomas Treated with Radiotherapy Plus Concomitant and Adjuvant Temozolomide.

    PubMed

    Saito, Taiichi; Sugiyama, Kazuhiko; Ikawa, Fusao; Yamasaki, Fumiyuki; Ishifuro, Minoru; Takayasu, Takeshi; Nosaka, Ryo; Nishibuchi, Ikuno; Muragaki, Yoshihiro; Kawamata, Takakazu; Kurisu, Kaoru

    2017-01-01

    The current standard treatment protocol for patients with newly diagnosed glioblastoma (GBM) includes surgery, radiotherapy, and concomitant and adjuvant temozolomide (TMZ). We hypothesized that the permeability surface area product (PS) from a perfusion computed tomography (PCT) study is associated with sensitivity to TMZ. The aim of this study was to determine whether PS values were correlated with prognosis of GBM patients who received the standard treatment protocol. This study included 36 patients with GBM that were newly diagnosed between October 2005 and September 2014 and who underwent preoperative PCT study and the standard treatment protocol. We measured the maximum value of relative cerebral blood volume (rCBVmax) and the maximum PS value (PSmax). We statistically examined the relationship between PSmax and prognosis using survival analysis, including other clinicopathologic factors (age, Karnofsky performance status [KPS], extent of resection, O6-methylguanine-DNA methyltransferase [MGMT] status, second-line use of bevacizumab, and rCBVmax). Log-rank tests revealed that age, KPS, MGMT status, and PSmax were significantly correlated with overall survival. Multivariate analysis using the Cox regression model showed that PSmax was the most significant prognostic factor. Receiver operating characteristic curve analysis showed that PSmax had the highest accuracy in differentiating longtime survivors (LTSs) (surviving more than 2 years) from non-LTSs. At a cutoff point of 8.26 mL/100 g/min, sensitivity and specificity were 90% and 70%, respectively. PSmax from PCT study can help predict survival time in patients with GBM receiving the standard treatment protocol. Survival may be related to sensitivity to TMZ. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Effects of standard training in the use of closed-circuit televisions in visually impaired adults: design of a training protocol and a randomized controlled trial

    PubMed Central

    2010-01-01

    Background Reading problems are frequently reported by visually impaired persons. A closed-circuit television (CCTV) can be helpful to maintain reading ability, however, it is difficult to learn how to use this device. In the Netherlands, an evidence-based rehabilitation program in the use of CCTVs was lacking. Therefore, a standard training protocol needed to be developed and tested in a randomized controlled trial (RCT) to provide an evidence-based training program in the use of this device. Methods/Design To develop a standard training program, information was collected by studying literature, observing training in the use of CCTVs, discussing the content of the training program with professionals and organizing focus and discussion groups. The effectiveness of the program was evaluated in an RCT, to obtain an evidence-based training program. Dutch patients (n = 122) were randomized into a treatment group: normal instructions from the supplier combined with training in the use of CCTVs, or into a control group: instructions from the supplier only. The effect of the training program was evaluated in terms of: change in reading ability (reading speed and reading comprehension), patients' skills to operate the CCTV, perceived (vision-related) quality of life and tasks performed in daily living. Discussion The development of the CCTV training protocol and the design of the RCT in the present study may serve as an example to obtain an evidence-based training program. The training program was adjusted to the needs and learning abilities of individual patients, however, for scientific reasons it might have been preferable to standardize the protocol further, in order to gain more comparable results. Trial registration http://www.trialregister.nl, identifier: NTR1031 PMID:20219120

  11. Impacts: NIST Building and Fire Research Laboratory (technical and societal)

    NASA Astrophysics Data System (ADS)

    Raufaste, N. J.

    1993-08-01

    The Building and Fire Research Laboratory (BFRL) of the National Institute of Standards and Technology (NIST) is dedicated to the life cycle quality of constructed facilities. The report describes major effects of BFRL's program on building and fire research. Contents of the document include: structural reliability; nondestructive testing of concrete; structural failure investigations; seismic design and construction standards; rehabilitation codes and standards; alternative refrigerants research; HVAC simulation models; thermal insulation; residential equipment energy efficiency; residential plumbing standards; computer image evaluation of building materials; corrosion-protection for reinforcing steel; prediction of the service lives of building materials; quality of construction materials laboratory testing; roofing standards; simulating fires with computers; fire safety evaluation system; fire investigations; soot formation and evolution; cone calorimeter development; smoke detector standards; standard for the flammability of children's sleepwear; smoldering insulation fires; wood heating safety research; in-place testing of concrete; communication protocols for building automation and control systems; computer simulation of the properties of concrete and other porous materials; cigarette-induced furniture fires; carbon monoxide formation in enclosure fires; halon alternative fire extinguishing agents; turbulent mixing research; materials fire research; furniture flammability testing; standard for the cigarette ignition resistance of mattresses; support of navy firefighter trainer program; and using fire to clean up oil spills.

  12. An Efficient Implementation of the Nwat-MMGBSA Method to Rescore Docking Results in Medium-Throughput Virtual Screenings

    NASA Astrophysics Data System (ADS)

    Maffucci, Irene; Hu, Xiao; Fumagalli, Valentina; Contini, Alessandro

    2018-03-01

    Nwat-MMGBSA is a variant of MM-PB/GBSA based on the inclusion of a number of explicit water molecules that are the closest to the ligand in each frame of a molecular dynamics trajectory. This method demonstrated improved correlations between calculated and experimental binding energies in both protein-protein interactions and ligand-receptor complexes, in comparison to the standard MM-GBSA. A protocol optimization, aimed to maximize efficacy and efficiency, is discussed here considering penicillopepsin, HIV1-protease, and BCL-XL as test cases. Calculations were performed in triplicates on both classic HPC environments and on standard workstations equipped by a GPU card, evidencing no statistical differences in the results. No relevant differences in correlation to experiments were also observed when performing Nwat-MMGBSA calculations on 4 ns or 1 ns long trajectories. A fully automatic workflow for structure-based virtual screening, performing from library set-up to docking and Nwat-MMGBSA rescoring, has then been developed. The protocol has been tested against no rescoring or standard MM-GBSA rescoring within a retrospective virtual screening of inhibitors of AmpC β-lactamase and of the Rac1-Tiam1 protein-protein interaction. In both cases, Nwat-MMGBSA rescoring provided a statistically significant increase in the ROC AUCs of between 20% and 30%, compared to docking scoring or to standard MM-GBSA rescoring.

  13. Conformance testing strategies for DICOM protocols in a heterogenous communications system

    NASA Astrophysics Data System (ADS)

    Meyer, Ralph; Hewett, Andrew J.; Cordonnier, Emmanuel; Piqueras, Joachim; Jensch, Peter F.

    1995-05-01

    The goal of the DICOM standard is to define a standard network interface and data model for imaging devices from various vendors. It shall facilitate the development and integration of information systems and picture archiving and communication systems (PACS) in a networked environment. Current activities in Oldenburg, Germany include projects to establish cooperative work applications for radiological purposes, comprising (joined) text, data, signal and image communications, based on narrowband ISDN and ATM communication for regional and Pan European applications. In such a growing and constantly changing environment it is vital to have a solid and implementable plan to bring standards in operation. A communication standard alone cannot ensure interoperability between different vendor implementations. Even DICOM does not specify implementation-specific requirements nor does it specify a testing procedure to assess an implementation's conformance to the standard. The conformance statements defined in the DICOM standard only allow a user to determine which optional components are supported by the implementation. The goal of our work is to build a conformance test suite for DICOM. Conformance testing can aid to simplify and solve problems with multivendor systems. It will check a vendor's implementation against the DICOM standard and state the found subset of functionality. The test suite will be built in respect to the ISO 9646 Standard (OSI-Conformance Testing Methodology and Framework) which is a standard devoted to the subject of conformance testing implementations of Open Systems Interconnection (OSI) standards. For our heterogeneous communication environments we must also consider ISO 9000 - 9004 (quality management and quality assurance) to give the users the confidence in evolving applications.

  14. Comparison of alternative βhCG follow-up protocols after single-dose methotrexate therapy for tubal ectopic pregnancy.

    PubMed

    Şükür, Yavuz Emre; Koyuncu, Kazibe; Seval, Mehmet Murat; Çetinkaya, Esra; Dökmeci, Fulya

    2017-12-01

    To evaluate the performances of five different βhCG follow-up protocols after single-dose methotrexate therapy for tubal ectopic pregnancy (EP). Data of patients who received single-dose methotrexate therapy for tubal EP at a university hospital between January 2011 and July 2016 were reviewed. A 'successful methotrexate treatment' was defined if the EP treated with no need for surgery. The performances of different protocols were tested by comparing with the currently used '15% βhCG decrease between days 4 and 7' protocol. The tested follow-up protocols were '20, 25%, and any βhCG decrease between days 0/1 and 7' and '20% and any βhCG decrease between days 0/1 and 4'. Among the 96 patients evaluated, 12 (12.5%) required second dose. Totally, 91 (94.8%) patients treated successfully with no need for surgery. Four patients were operated within 4 days following the second dose. One patient who did not need second dose according to the standard follow-up protocol was operated on the 10th day due to rupture (specificity = 80%). Two protocols, namely '20% βhCG decrease between days 0/1 and 7' and 'any βhCG decrease between days 0/1 and 7' did not show statistically significant differences from the index protocol regarding the number of patients who should be assigned to 2nd dose. 'Any βhCG decrease between days 0/1 and 7' protocol may substitute the currently used one to decide second dose methotrexate in tubal EP management. Omitting 4th day measurement seems to be more convenient and cost effective.

  15. Testing warning messages on smokers’ cigarette packages: A standardized protocol

    PubMed Central

    Brewer, Noel T.; Hall, Marissa G.; Lee, Joseph G. L.; Peebles, Kathryn; Noar, Seth M.; Ribisl, Kurt M.

    2015-01-01

    Purpose Lab experiments on cigarette warnings typically use a brief one-time exposure that is not paired with the cigarette packs smokers use every day, leaving open the question of how repeated warning exposure over several weeks may affect smokers. This proof of principle study sought to develop a new protocol for testing cigarette warnings that better reflects real-world exposure by presenting them on cigarette smokers’ own packs. Methods We tested a cigarette pack labeling protocol with 76 US smokers ages 18 and older. We applied graphic warnings to the front and back of smokers’ cigarette packs. Results Most smokers reported that at least 75% of the packs of cigarettes they smoked during the study had our warnings. Nearly all said they would participate in the study again. Using cigarette packs with the study warnings increased quit intentions (p<.05). Conclusion Our findings suggest a feasible pack labeling protocol with six steps: (1) schedule appointments at brief intervals; (2) determine typical cigarette consumption; (3) ask smokers to bring a supply of cigarette packs to study appointments; (4) apply labels to smokers’ cigarette packs; (5) provide participation incentives at the end of appointments; and (6) refer smokers to cessation services at end of the study. When used in randomized controlled trials in settings with real-world message exposure over time, this protocol may help identify the true impact of warnings and thus better inform tobacco product labeling policy. PMID:25564282

  16. University of Washington/ Northwest National Marine Renewable Energy Center Tidal Current Technology Test Protocol, Instrumentation, Design Code, and Oceanographic Modeling Collaboration: Cooperative Research and Development Final Report, CRADA Number CRD-11-452

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Driscoll, Frederick R.

    The University of Washington (UW) - Northwest National Marine Renewable Energy Center (UW-NNMREC) and the National Renewable Energy Laboratory (NREL) will collaborate to advance research and development (R&D) of Marine Hydrokinetic (MHK) renewable energy technology, specifically renewable energy captured from ocean tidal currents. UW-NNMREC is endeavoring to establish infrastructure, capabilities and tools to support in-water testing of marine energy technology. NREL is leveraging its experience and capabilities in field testing of wind systems to develop protocols and instrumentation to advance field testing of MHK systems. Under this work, UW-NNMREC and NREL will work together to develop a common instrumentation systemmore » and testing methodologies, standards and protocols. UW-NNMREC is also establishing simulation capabilities for MHK turbine and turbine arrays. NREL has extensive experience in wind turbine array modeling and is developing several computer based numerical simulation capabilities for MHK systems. Under this CRADA, UW-NNMREC and NREL will work together to augment single device and array modeling codes. As part of this effort UW NNMREC will also work with NREL to run simulations on NREL's high performance computer system.« less

  17. Intensive Sensorimotor Arm Training Mediated by Therapist or Robot Improves Hemiparesis in Patients With Chronic Stroke

    PubMed Central

    Volpe, Bruce T.; Lynch, Daniel; Rykman-Berland, Avrielle; Ferraro, Mark; Galgano, Michael; Hogan, Neville; Krebs, Hermano I.

    2016-01-01

    Investigators have demonstrated that a variety of intensive movement training protocols for persistent upper limb paralysis in patients with chronic stroke (6 months or more after stroke) improve motor outcome. This randomized controlled study determined in patients with upper limb motor impairment after chronic stroke whether movement therapy delivered by a robot or by a therapist using an intensive training protocol was superior. Robotic training (n = 11) and an intensive movement protocol (n = 10) improved the impairment measures of motor outcome significantly and comparably; there were no significant changes in disability measures. Motor gains were maintained at the 3-month evaluation after training. These data contribute to the growing awareness that persistent impairments in those with chronic stroke may not reflect exhausted capacity for improvement. These new protocols, rendered by either therapist or robot, can be standardized, tested, and replicated, and potentially will contribute to rational activity-based programs. PMID:18184932

  18. PR-PR: Cross-Platform Laboratory Automation System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Linshiz, G; Stawski, N; Goyal, G

    To enable protocol standardization, sharing, and efficient implementation across laboratory automation platforms, we have further developed the PR-PR open-source high-level biology-friendly robot programming language as a cross-platform laboratory automation system. Beyond liquid-handling robotics, PR-PR now supports microfluidic and microscopy platforms, as well as protocol translation into human languages, such as English. While the same set of basic PR-PR commands and features are available for each supported platform, the underlying optimization and translation modules vary from platform to platform. Here, we describe these further developments to PR-PR, and demonstrate the experimental implementation and validation of PR-PR protocols for combinatorial modified Goldenmore » Gate DNA assembly across liquid-handling robotic, microfluidic, and manual platforms. To further test PR-PR cross-platform performance, we then implement and assess PR-PR protocols for Kunkel DNA mutagenesis and hierarchical Gibson DNA assembly for microfluidic and manual platforms.« less

  19. A protocol for isolating insect mitochondrial genomes: a case study of NUMT in Melipona flavolineata (Hymenoptera: Apidae).

    PubMed

    Françoso, Elaine; Gomes, Fernando; Arias, Maria Cristina

    2016-07-01

    Nuclear mitochondrial DNA insertions (NUMTs) are mitochondrial DNA sequences that have been transferred into the nucleus and are recognized by the presence of indels and stop codons. Although NUMTs have been identified in a diverse range of species, their discovery was frequently accidental. Here, our initial goal was to develop and standardize a simple method for isolating NUMTs from the nuclear genome of a single bee. Subsequently, we tested our new protocol by determining whether the indels and stop codons of the cytochrome c oxidase subunit I (COI) sequence of Melipona flavolineata are of nuclear origin. The new protocol successfully demonstrated the presence of a COI NUMT. In addition to NUMT investigations, the protocol described here will also be very useful for studying mitochondrial mutations related to diseases and for sequencing complete mitochondrial genomes with high read coverage by Next-Generation technology.

  20. PR-PR: cross-platform laboratory automation system.

    PubMed

    Linshiz, Gregory; Stawski, Nina; Goyal, Garima; Bi, Changhao; Poust, Sean; Sharma, Monica; Mutalik, Vivek; Keasling, Jay D; Hillson, Nathan J

    2014-08-15

    To enable protocol standardization, sharing, and efficient implementation across laboratory automation platforms, we have further developed the PR-PR open-source high-level biology-friendly robot programming language as a cross-platform laboratory automation system. Beyond liquid-handling robotics, PR-PR now supports microfluidic and microscopy platforms, as well as protocol translation into human languages, such as English. While the same set of basic PR-PR commands and features are available for each supported platform, the underlying optimization and translation modules vary from platform to platform. Here, we describe these further developments to PR-PR, and demonstrate the experimental implementation and validation of PR-PR protocols for combinatorial modified Golden Gate DNA assembly across liquid-handling robotic, microfluidic, and manual platforms. To further test PR-PR cross-platform performance, we then implement and assess PR-PR protocols for Kunkel DNA mutagenesis and hierarchical Gibson DNA assembly for microfluidic and manual platforms.

  1. A Protocol for Advanced Psychometric Assessment of Surveys

    PubMed Central

    Squires, Janet E.; Hayduk, Leslie; Hutchinson, Alison M.; Cranley, Lisa A.; Gierl, Mark; Cummings, Greta G.; Norton, Peter G.; Estabrooks, Carole A.

    2013-01-01

    Background and Purpose. In this paper, we present a protocol for advanced psychometric assessments of surveys based on the Standards for Educational and Psychological Testing. We use the Alberta Context Tool (ACT) as an exemplar survey to which this protocol can be applied. Methods. Data mapping, acceptability, reliability, and validity are addressed. Acceptability is assessed with missing data frequencies and the time required to complete the survey. Reliability is assessed with internal consistency coefficients and information functions. A unitary approach to validity consisting of accumulating evidence based on instrument content, response processes, internal structure, and relations to other variables is taken. We also address assessing performance of survey data when aggregated to higher levels (e.g., nursing unit). Discussion. In this paper we present a protocol for advanced psychometric assessment of survey data using the Alberta Context Tool (ACT) as an exemplar survey; application of the protocol to the ACT survey is underway. Psychometric assessment of any survey is essential to obtaining reliable and valid research findings. This protocol can be adapted for use with any nursing survey. PMID:23401759

  2. A standardized test battery for the study of synesthesia

    PubMed Central

    Eagleman, David M.; Kagan, Arielle D.; Nelson, Stephanie S.; Sagaram, Deepak; Sarma, Anand K.

    2014-01-01

    Synesthesia is an unusual condition in which stimulation of one modality evokes sensation or experience in another modality. Although discussed in the literature well over a century ago, synesthesia slipped out of the scientific spotlight for decades because of the difficulty in verifying and quantifying private perceptual experiences. In recent years, the study of synesthesia has enjoyed a renaissance due to the introduction of tests that demonstrate the reality of the condition, its automatic and involuntary nature, and its measurable perceptual consequences. However, while several research groups now study synesthesia, there is no single protocol for comparing, contrasting and pooling synesthetic subjects across these groups. There is no standard battery of tests, no quantifiable scoring system, and no standard phrasing of questions. Additionally, the tests that exist offer no means for data comparison. To remedy this deficit we have devised the Synesthesia Battery. This unified collection of tests is freely accessible online (http://www.synesthete.org). It consists of a questionnaire and several online software programs, and test results are immediately available for use by synesthetes and invited researchers. Performance on the tests is quantified with a standard scoring system. We introduce several novel tests here, and offer the software for running the tests. By presenting standardized procedures for testing and comparing subjects, this endeavor hopes to speed scientific progress in synesthesia research. PMID:16919755

  3. Understanding protocol performance: impact of test performance.

    PubMed

    Turner, Robert G

    2013-01-01

    This is the second of two articles that examine the factors that determine protocol performance. The objective of these articles is to provide a general understanding of protocol performance that can be used to estimate performance, establish limits on performance, decide if a protocol is justified, and ultimately select a protocol. The first article was concerned with protocol criterion and test correlation. It demonstrated the advantages and disadvantages of different criterion when all tests had the same performance. It also examined the impact of increasing test correlation on protocol performance and the characteristics of the different criteria. To examine the impact on protocol performance when individual tests in a protocol have different performance. This is evaluated for different criteria and test correlations. The results of the two articles are combined and summarized. A mathematical model is used to calculate protocol performance for different protocol criteria and test correlations when there are small to large variations in the performance of individual tests in the protocol. The performance of the individual tests that make up a protocol has a significant impact on the performance of the protocol. As expected, the better the performance of the individual tests, the better the performance of the protocol. Many of the characteristics of the different criteria are relatively independent of the variation in the performance of the individual tests. However, increasing test variation degrades some criteria advantages and causes a new disadvantage to appear. This negative impact increases as test variation increases and as more tests are added to the protocol. Best protocol performance is obtained when individual tests are uncorrelated and have the same performance. In general, the greater the variation in the performance of tests in the protocol, the more detrimental this variation is to protocol performance. Since this negative impact is increased as more tests are added to the protocol, greater test variation indicates using fewer tests in the protocol. American Academy of Audiology.

  4. TU-G-BRD-04: A Round Robin Dosimetry Intercomparison of Gamma Stereotactic Radiosurgery Calibration Protocols

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Drzymala, R; Alvarez, P; Bednarz, G

    2015-06-15

    Purpose: The purpose of this multi-institutional study was to compare two new gamma stereotactic radiosurgery (GSRS) dosimetry protocols to existing calibration methods. The ultimate goal was to guide AAPM Task Group 178 in recommending a standard GSRS dosimetry protocol. Methods: Nine centers (ten GSRS units) participated in the study. Each institution made eight sets of dose rate measurements: six with two different ionization chambers in three different 160mm-diameter spherical phantoms (ABS plastic, Solid Water and liquid water), and two using the same ionization chambers with a custom in-air positioning jig. Absolute dose rates were calculated using a newly proposed formalismmore » by the IAEA working group for small and non-standard radiation fields and with a new air-kerma based protocol. The new IAEA protocol requires an in-water ionization chamber calibration and uses previously reported Monte-Carlo generated factors to account for the material composition of the phantom, the type of ionization chamber, and the unique GSRS beam configuration. Results obtained with the new dose calibration protocols were compared to dose rates determined by the AAPM TG-21 and TG-51 protocols, with TG-21 considered as the standard. Results: Averaged over all institutions, ionization chambers and phantoms, the mean dose rate determined with the new IAEA protocol relative to that determined with TG-21 in the ABS phantom was 1.000 with a standard deviation of 0.008. For TG-51, the average ratio was 0.991 with a standard deviation of 0.013, and for the new in-air formalism it was 1.008 with a standard deviation of 0.012. Conclusion: Average results with both of the new protocols agreed with TG-21 to within one standard deviation. TG-51, which does not take into account the unique GSRS beam configuration or phantom material, was not expected to perform as well as the new protocols. The new IAEA protocol showed remarkably good agreement with TG-21. Conflict of Interests: Paula Petti, Josef Novotny, Gennady Neyman and Steve Goetsch are consultants for Elekta Instrument A/B; Elekta Instrument AB, PTW Freiburg GmbH, Standard Imaging, Inc., and The Phantom Laboratory, Inc. loaned equipment for use in these experiments; The University of Wisconsin Accredited Dosimetry Calibration Laboratory provided calibration services.« less

  5. A Standard Mutual Authentication Protocol for Cloud Computing Based Health Care System.

    PubMed

    Mohit, Prerna; Amin, Ruhul; Karati, Arijit; Biswas, G P; Khan, Muhammad Khurram

    2017-04-01

    Telecare Medical Information System (TMIS) supports a standard platform to the patient for getting necessary medical treatment from the doctor(s) via Internet communication. Security protection is important for medical records (data) of the patients because of very sensitive information. Besides, patient anonymity is another most important property, which must be protected. Most recently, Chiou et al. suggested an authentication protocol for TMIS by utilizing the concept of cloud environment. They claimed that their protocol is patient anonymous and well security protected. We reviewed their protocol and found that it is completely insecure against patient anonymity. Further, the same protocol is not protected against mobile device stolen attack. In order to improve security level and complexity, we design a light weight authentication protocol for the same environment. Our security analysis ensures resilience of all possible security attacks. The performance of our protocol is relatively standard in comparison with the related previous research.

  6. EPA Traceability Protocol for Assay and Certification of Gaseous Calibration Standards

    EPA Science Inventory

    In 1997, the U.S. Environmental Protection Agency (EPA) in Research Triangle Park, North Carolina, revised its 1993 version of its traceability protocol for the assay and certification of compressed gas and permeation-device calibration standards. The protocol allows producers o...

  7. Analysis of simulated angiographic procedures. Part 2: extracting efficiency data from audio and video recordings.

    PubMed

    Duncan, James R; Kline, Benjamin; Glaiberman, Craig B

    2007-04-01

    To create and test methods of extracting efficiency data from recordings of simulated renal stent procedures. Task analysis was performed and used to design a standardized testing protocol. Five experienced angiographers then performed 16 renal stent simulations using the Simbionix AngioMentor angiographic simulator. Audio and video recordings of these simulations were captured from multiple vantage points. The recordings were synchronized and compiled. A series of efficiency metrics (procedure time, contrast volume, and tool use) were then extracted from the recordings. The intraobserver and interobserver variability of these individual metrics was also assessed. The metrics were converted to costs and aggregated to determine the fixed and variable costs of a procedure segment or the entire procedure. Task analysis and pilot testing led to a standardized testing protocol suitable for performance assessment. Task analysis also identified seven checkpoints that divided the renal stent simulations into six segments. Efficiency metrics for these different segments were extracted from the recordings and showed excellent intra- and interobserver correlations. Analysis of the individual and aggregated efficiency metrics demonstrated large differences between segments as well as between different angiographers. These differences persisted when efficiency was expressed as either total or variable costs. Task analysis facilitated both protocol development and data analysis. Efficiency metrics were readily extracted from recordings of simulated procedures. Aggregating the metrics and dividing the procedure into segments revealed potential insights that could be easily overlooked because the simulator currently does not attempt to aggregate the metrics and only provides data derived from the entire procedure. The data indicate that analysis of simulated angiographic procedures will be a powerful method of assessing performance in interventional radiology.

  8. Automated Data Quality Assurance using OGC Sensor Web Enablement Frameworks for Marine Observatories

    NASA Astrophysics Data System (ADS)

    Toma, Daniel; Bghiel, Ikram; del Rio, Joaquin; Hidalgo, Alberto; Carreras, Normandino; Manuel, Antoni

    2014-05-01

    Over the past years, environmental sensors have continuously improved by becoming smaller, cheaper, and more intelligent. Therefore, many sensor networks are increasingly deployed to monitor our environment. But due to the large number of sensor manufacturers, accompanying protocols and data encoding, automated integration and data quality assurance of diverse sensors in an observing systems is not straightforward, requiring development of data management code and manual tedious configuration. However, over the past few years it has been demonstrated that Open-Geospatial Consortium (OGC) frameworks can enable web services with fully-described sensor systems, including data processing, sensor characteristics and quality control tests and results. So far, the SWE framework does not describe how to integrate sensors on-the-fly with minimal human intervention. The data management software which enables access to sensors, data processing and quality control tests has to be implemented and the results have to be manually mapped to the SWE models. In this contribution, we describe a Sensor Plug & Play infrastructure for the Sensor Web by combining (1) OGC PUCK protocol - a simple standard embedded instrument protocol to store and retrieve directly from the devices the declarative description of sensor characteristics and quality control tests, (2) an automatic mechanism for data processing and quality control tests underlying the Sensor Web - the Sensor Interface Descriptor (SID) concept, as well as (3) a model for the declarative description of sensor which serves as a generic data management mechanism - designed as a profile and extension of OGC SWE's SensorML standard. We implement and evaluate our approach by applying it to the OBSEA Observatory, and can be used to demonstrate the ability to assess data quality for temperature, salinity, air pressure and wind speed and direction observations off the coast of Garraf, in the north-eastern Spain.

  9. Accurate, simple, and inexpensive assays to diagnose F8 gene inversion mutations in hemophilia A patients and carriers.

    PubMed

    Dutta, Debargh; Gunasekera, Devi; Ragni, Margaret V; Pratt, Kathleen P

    2016-12-27

    The most frequent mutations resulting in hemophilia A are an intron 22 or intron 1 gene inversion, which together cause ∼50% of severe hemophilia A cases. We report a simple and accurate RNA-based assay to detect these mutations in patients and heterozygous carriers. The assays do not require specialized equipment or expensive reagents; therefore, they may provide useful and economic protocols that could be standardized for central laboratory testing. RNA is purified from a blood sample, and reverse transcription nested polymerase chain reaction (RT-NPCR) reactions amplify DNA fragments with the F8 sequence spanning the exon 22 to 23 splice site (intron 22 inversion test) or the exon 1 to 2 splice site (intron 1 inversion test). These sequences will be amplified only from F8 RNA without an intron 22 or intron 1 inversion mutation, respectively. Additional RT-NPCR reactions are then carried out to amplify the inverted sequences extending from F8 exon 19 to the first in-frame stop codon within intron 22 or a chimeric transcript containing F8 exon 1 and the VBP1 gene. These latter 2 products are produced only by individuals with an intron 22 or intron 1 inversion mutation, respectively. The intron 22 inversion mutations may be further classified (eg, as type 1 or type 2, reflecting the specific homologous recombination sites) by the standard DNA-based "inverse-shifting" PCR assay if desired. Efficient Bcl I and T4 DNA ligase enzymes that cleave and ligate DNA in minutes were used, which is a substantial improvement over previous protocols that required overnight incubations. These protocols can accurately detect F8 inversion mutations via same-day testing of patient samples.

  10. A study of the effectiveness of particulate cleaning protocols on intentionally contaminated niobium surfaces

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reece, Charles E.; Ciancio, Elizabeth J.; Keyes, Katharine A.

    2009-11-01

    Particulate contamination on the surface of SRF cavities limits their performance via the enhanced generation of field-emitted electrons. Considerable efforts are expended to actively clean and avoid such contamination on niobium surfaces. The protocols in active use have been developed via feedback from cavity testing. This approach has the risk of over-conservatively ratcheting an ever increasing complexity of methods tied to particular circumstances. A complementary and perhaps helpful approach is to quantitatively assess the effectiveness of candidate methods at removing intentional representative particulate contamination. Toward this end, we developed a standardized contamination protocol using water suspensions of Nb{sub 2}O{sub 5}more » and SS 316 powders applied to BCP’d surfaces of standardized niobium samples yielding particle densities of order 200 particles/mm{sup 2}. From these starting conditions, controlled application of high pressure water rinse, ultrasonic cleaning, or CO{sub 2} snow jet cleaning was applied and the resulting surfaces examined via SEM/scanning EDS with particle recognition software. Results of initial parametric variations of each will be reported.« less

  11. Electric Vehicle Communication Standards Testing and Validation Phase I: SAE J2847/1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pratt, Richard M.; Tuffner, Francis K.; Gowri, Krishnan

    Executive Summary Vehicle to grid communication standards are critical to the charge management and interoperability among vehicles, charging stations and utility providers. Several standards initiatives by the Society of Automobile Engineers (SAE), International Standards Organization and International Electrotechnical Commission (ISO/IEC), and ZigBee / HomePlug Alliance are developing requirements for communication messages and protocols. While the standard development is in progress for more than two years, no definitive guidelines are available for the automobile manufacturers, charging station manufacturers and utility backhaul network systems. At present, there is a wide range of proprietary communication options developed and supported in the industry. Recentmore » work by the Electric Power Research Institute (EPRI) in collaboration with SAE and automobile manufacturers has identified performance requirements and test plan based on possible communication pathways using power line communication over the control pilot and mains. Though the communication pathways and power line communication technology options are identified, much work needs to be done in developing application software and testing of communication modules before these can be deployed in production vehicles. This report presents a test plan and results from initial testing of two power line communication modules developed to meet the requirements of SAE J2847/1 standard.« less

  12. Comparison of ventilation threshold and heart rate deflection point in fast and standard treadmill test protocols.

    PubMed

    Vucetić, Vlatko; Sentija, Davor; Sporis, Goran; Trajković, Nebojsa; Milanović, Zoran

    2014-06-01

    The purpose of this study was to compare two methods for determination of anaerobic threshold from two different treadmill protocols. Forty-eight Croatian runners of national rank (ten sprinters, fifteen 400-m runners, ten middle distance runners and thirteen long distance runners), mean age 21.7 +/- 5.1 years, participated in the study. They performed two graded maximal exercise tests on a treadmill, a standard ramp treadmill test (T(SR), speed increments of 1 km x h(-1) every 60 seconds) and a fast ramp treadmill test (T(FR), speed increments of 1 km x h(-1) every 30 seconds) to determine and compare the parameters at peak values and at heart rate at the deflection point (HR(DP)) and ventilation threshold (VT). There were no significant differences between protocols (p > 0.05) for peak values of oxygen uptake (VO(2max), 4.48 +/- 0.43 and 4.44 +/- 0.45 L x min(-1)), weight related VO(2max) (62.5 +/- 6.2 and 62.0 +/- 6.0 mL x kg(-1) x min(-1)), pulmonary ventilation (VE(max), 163.1 +/- 18.7 and 161.3 +/- 19.9 L x min(-1)) and heart rate (HR(max), 192.3 +/- 8.5 and 194.4 +/- 8.7 bpm) (T(FR) and T(SR), respectively). Moreover, no significant differences between T(FR) and T(SR) where found for VT and HR(DP) when expressed as VO2 and HR. However, there was a significant effect of ramp slope on running speed at VO(2max) and at the anaerobic threshold (AnT), independent of the method used (VT: 16.0 +/- 2.2 vs 14.9 +/- 2.2 km x h(-1);HR(DP): 16.5 +/- 1.9 vs 14.9 +/- 2.0 km x h(-1) for T(FR) and T(SR) respectively). Linear regression analysis revealed high between-test and between-method correlations for VO2, HR and running speed parameters (r = 0.78-0.89, p < 0.01). The present study has indicated that the VT and HR(DP) for running (VO2, ventilation, and heart rate at VT/HR(DP)) are independent of test protocol, while there is a significant effect of ramp slope on VT and HR(DP) when expressed as running speed. Moreover, this study demonstrates that the point of deflection from linearity of heart rate may be an accurate predictor of the anaerobic threshold in trained runners, independently of the protocol used.

  13. Methacholine challenge testing: improved patient comfort with a 2-tiered protocol.

    PubMed

    Segel, Michael J; Rabinovich, Einat; Schwarz, Yehuda; Ben-Dov, Issahar

    2013-06-01

    The methacholine challenge test (MCT) is a test of bronchial hyperreactivity used as an aid in the diagnosis of asthma. MCT results are reported as the provocation concentration at which the forced expiratory volume in 1 second (FEV1) decreases 20% (PC20). The requirement for a 20% or greater decrease in FEV1 results in precipitous decreases in FEV1 in some patients. To improve MCT safety without compromising accuracy. We performed a retrospective analysis of 879 consecutive MCTs (derivation cohort). A novel protocol for MCT was developed and validated in a cohort of 564 MCTs performed in a second institution. In comparison with a PC20 cutoff of less than 8 mg/mL, a provocation concentration at which the FEV1 decreases 10% (PC10) cutoff of 1 mg/mL or less has a sensitivity of 86%, a specificity of 98%, a positive predictive value (PPV) of 97%, and a negative predictive value (NPV) of 91%. We propose a novel 2-tiered protocol for MCT. If the PC10 is 1 mg/mL or less, bronchial hyperreactivity is present; if the PC10 is greater than 1 mg/mL, the test is continued until the provocative concentration is 8 mg/mL or a 20% decrease in FEV1 is achieved. Compared with the standard protocol, the proposed protocol has a sensitivity, specificity, PPV, NPV, and overall accuracy of 100%, 98%, 97.6%, 100%, and 99%, respectively. The modified protocol would have enabled us to avoid 26 of 42 cases (62%) in which a 40% or greater decrease in FEV1 occurred and would save 0.65 dose for every MCT performed. The 2-tiered protocol performed well in the validation cohort; sensitivity, specificity, PPV, NPV, and overall accuracy were 100%, 98%, 87%, 100%, and 98%, respectively. The proposed 2-tiered protocol is accurate, saves time, and avoids precipitous decreases in FEV1. Copyright © 2013 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  14. Deployment of Directory Service for IEEE N Bus Test System Information

    NASA Astrophysics Data System (ADS)

    Barman, Amal; Sil, Jaya

    2008-10-01

    Exchanging information over Internet and Intranet becomes a defacto standard in computer applications, among various users and organizations. Distributed system study, e-governance etc require transparent information exchange between applications, constituencies, manufacturers, and vendors. To serve these purposes database system is needed for storing system data and other relevant information. Directory service, which is a specialized database along with access protocol, could be the single solution since it runs over TCP/IP, supported by all POSIX compliance platforms and is based on open standard. This paper describes a way to deploy directory service, to store IEEE n bus test system data and integrating load flow program with it.

  15. Saccadic vector optokinetic perimetry in children with neurodisability or isolated visual pathway lesions: observational cohort study.

    PubMed

    Tailor, Vijay; Glaze, Selina; Unwin, Hilary; Bowman, Richard; Thompson, Graham; Dahlmann-Noor, Annegret

    2016-10-01

    Children and adults with neurological impairments are often not able to access conventional perimetry; however, information about the visual field is valuable. A new technology, saccadic vector optokinetic perimetry (SVOP), may have improved accessibility, but its accuracy has not been evaluated. We aimed to explore accessibility, testability and accuracy of SVOP in children with neurodisability or isolated visual pathway deficits. Cohort study; recruitment October 2013-May 2014, at children's eye clinics at a tertiary referral centre and a regional Child Development Centre; full orthoptic assessment, SVOP (central 30° of the visual field) and confrontation visual fields (CVF). Group 1: age 1-16 years, neurodisability (n=16), group 2: age 10-16 years, confirmed or suspected visual field defect (n=21); group 2 also completed Goldmann visual field testing (GVFT). Group 1: testability with a full 40-point test protocol is 12.5%; with reduced test protocols, testability is 100%, but plots may be clinically meaningless. Children (44%) and parents/carers (62.5%) find the test easy. SVOP and CVF agree in 50%. Group 2: testability is 62% for the 40-point protocol, and 90.5% for reduced protocols. Corneal changes in childhood glaucoma interfere with SVOP testing. All children and parents/carers find SVOP easy. Overall agreement with GVFT is 64.7%. While SVOP is highly accessible to children, many cannot complete a full 40-point test. Agreement with current standard tests is moderate to poor. Abnormal saccades cause an apparent non-specific visual field defect. In children with glaucoma or nystagmus SVOP calibration often fails. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  16. Towards sensible toxicity testing for nanomaterials: proposal for the specification of test design

    NASA Astrophysics Data System (ADS)

    Potthoff, Annegret; Weil, Mirco; Meißner, Tobias; Kühnel, Dana

    2015-12-01

    During the last decade, nanomaterials (NM) were extensively tested for potential harmful effects towards humans and environmental organisms. However, a sound hazard assessment was so far hampered by uncertainties and a low comparability of test results. The reason for the low comparability is a high variation in the (1) type of NM tested with regard to raw material, size and shape and (2) procedures before and during the toxicity testing. This calls for tailored, nanomaterial-specific protocols. Here, a structured approach is proposed, intended to lead to test protocols not only tailored to specific types of nanomaterials, but also to respective test system for toxicity testing. There are existing standards on single procedures involving nanomaterials, however, not all relevant procedures are covered by standards. Hence, our approach offers a detailed way of weighting several plausible alternatives for e.g. sample preparation, in order to decide on the procedure most meaningful for a specific nanomaterial and toxicity test. A framework of several decision trees (DT) and flow charts to support testing of NM is proposed as a basis for further refinement and in-depth elaboration. DT and flow charts were drafted for (1) general procedure—physicochemical characterisation, (2) choice of test media, (3) decision on test scenario and application of NM to liquid media, (4) application of NM to the gas phase, (5) application of NM to soil and sediments, (6) dose metrics, (S1) definition of a nanomaterial, and (S2) dissolution. The applicability of the proposed approach was surveyed by using experimental data retrieved from studies on nanoscale CuO. This survey demonstrated the DT and flow charts to be a convenient tool to systematically decide upon test procedures and processes, and hence pose an important step towards harmonisation of NM testing.

  17. Towards sensible toxicity testing for nanomaterials: proposal for the specification of test design.

    PubMed

    Potthoff, Annegret; Weil, Mirco; Meißner, Tobias; Kühnel, Dana

    2015-12-01

    During the last decade, nanomaterials (NM) were extensively tested for potential harmful effects towards humans and environmental organisms. However, a sound hazard assessment was so far hampered by uncertainties and a low comparability of test results. The reason for the low comparability is a high variation in the (1) type of NM tested with regard to raw material, size and shape and (2) procedures before and during the toxicity testing. This calls for tailored, nanomaterial-specific protocols. Here, a structured approach is proposed, intended to lead to test protocols not only tailored to specific types of nanomaterials, but also to respective test system for toxicity testing. There are existing standards on single procedures involving nanomaterials, however, not all relevant procedures are covered by standards. Hence, our approach offers a detailed way of weighting several plausible alternatives for e.g. sample preparation, in order to decide on the procedure most meaningful for a specific nanomaterial and toxicity test. A framework of several decision trees (DT) and flow charts to support testing of NM is proposed as a basis for further refinement and in-depth elaboration. DT and flow charts were drafted for (1) general procedure-physicochemical characterisation, (2) choice of test media, (3) decision on test scenario and application of NM to liquid media, (4) application of NM to the gas phase, (5) application of NM to soil and sediments, (6) dose metrics, (S1) definition of a nanomaterial, and (S2) dissolution. The applicability of the proposed approach was surveyed by using experimental data retrieved from studies on nanoscale CuO. This survey demonstrated the DT and flow charts to be a convenient tool to systematically decide upon test procedures and processes, and hence pose an important step towards harmonisation of NM testing.

  18. Aerospace physiology.

    DOT National Transportation Integrated Search

    2004-01-01

    This document defines the protocol standards for the Internet Protocol Suite (IPS), which is commonly referred to as Transmission Control Protocol/Internet Protocol (TCP/IP) protocols used for data communications within the National Airspace System (...

  19. Visibility-Based Hypothesis Testing Using Higher-Order Optical Interference

    NASA Astrophysics Data System (ADS)

    Jachura, Michał; Jarzyna, Marcin; Lipka, Michał; Wasilewski, Wojciech; Banaszek, Konrad

    2018-03-01

    Many quantum information protocols rely on optical interference to compare data sets with efficiency or security unattainable by classical means. Standard implementations exploit first-order coherence between signals whose preparation requires a shared phase reference. Here, we analyze and experimentally demonstrate the binary discrimination of visibility hypotheses based on higher-order interference for optical signals with a random relative phase. This provides a robust protocol implementation primitive when a phase lock is unavailable or impractical. With the primitive cost quantified by the total detected optical energy, optimal operation is typically reached in the few-photon regime.

  20. 40 CFR 63.642 - General standards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... reduction. (4) Data shall be reduced in accordance with the EPA-approved methods specified in the applicable section or, if other test methods are used, the data and methods shall be validated according to the protocol in Method 301 of appendix A of this part. (e) Each owner or operator of a source subject to this...

  1. 21 CFR 660.36 - Samples and protocols.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ..., whenever a new donor is used, a sample of red blood cells from each new donor used in a cell panel intended... ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.36 Samples... distribution of each lot of Reagent Red Blood Cells for detection or identification of unexpected antibodies...

  2. 21 CFR 660.36 - Samples and protocols.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ..., whenever a new donor is used, a sample of red blood cells from each new donor used in a cell panel intended... ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.36 Samples... distribution of each lot of Reagent Red Blood Cells for detection or identification of unexpected antibodies...

  3. 21 CFR 660.36 - Samples and protocols.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ..., whenever a new donor is used, a sample of red blood cells from each new donor used in a cell panel intended... ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.36 Samples... distribution of each lot of Reagent Red Blood Cells for detection or identification of unexpected antibodies...

  4. Not Just a Prayer before a Test: Theodicy among Students

    ERIC Educational Resources Information Center

    Daugherty, Timothy K.; Han, Suejung

    2016-01-01

    The purpose of this study was to examine the potential social and academic impact of theodicy, perceived control of events by God. The sample included 428 college students from two public universities, consenting to complete internet-based protocols. Standardized measures included the Theodicy Scale (Daugherty et al., 2009), Work Related…

  5. 40 CFR 63.788 - Recordkeeping and reporting requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... containers meet the standards as described in § 63.783(b)(2); and (vii) The results of any Method 24 of appendix A to 40 CFR part 60 or approved VOHAP measurement test conducted on individual containers of... summary of the number and total duration of incidents that the monitoring protocol failed to perform in...

  6. Implementation and Evaluation of Four Interoperable Open Standards for the Internet of Things.

    PubMed

    Jazayeri, Mohammad Ali; Liang, Steve H L; Huang, Chih-Yuan

    2015-09-22

    Recently, researchers are focusing on a new use of the Internet called the Internet of Things (IoT), in which enabled electronic devices can be remotely accessed over the Internet. As the realization of IoT concept is still in its early stages, manufacturers of Internet-connected devices and IoT web service providers are defining their proprietary protocols based on their targeted applications. Consequently, IoT becomes heterogeneous in terms of hardware capabilities and communication protocols. Addressing these heterogeneities by following open standards is a necessary step to communicate with various IoT devices. In this research, we assess the feasibility of applying existing open standards on resource-constrained IoT devices. The standard protocols developed in this research are OGC PUCK over Bluetooth, TinySOS, SOS over CoAP, and OGC SensorThings API. We believe that by hosting open standard protocols on IoT devices, not only do the devices become self-describable, self-contained, and interoperable, but innovative applications can also be easily developed with standardized interfaces. In addition, we use memory consumption, request message size, response message size, and response latency to benchmark the efficiency of the implemented protocols. In all, this research presents and evaluates standard-based solutions to better understand the feasibility of applying existing standards to the IoT vision.

  7. Validation of HPLC-ESI-MS/MS Protocol to Analyze EtG in Hair for Assessment of Chronic Excessive Alcohol Use in Thailand in Conjunction with AUDIT.

    PubMed

    Thananchai, Thiwaphorn; Junkuy, Anongphan; Kittirattanapaiboon, Phunnapa; Sribanditmongkol, Pongruk

    2016-06-01

    Hair analysis for chronic excessive alcohol (ethanol) use has focused on ethyl glucuronide (EtG), a minor metabolite of ethanol. Preferred methods have involved high-performance liquid chromatography (HPLC) combined with tandem mass spectrometry (MS/MS) in line with an electrospray ionization (ESI) source. EtG analysis in hair has not yet been introduced to Thailand To validate an in-house HPLC-ESI-MS/MS hair analysis protocol for EtG and to apply it to a field sample of alcohol drinkers to assess different risk levels of alcohol consumption as measured by the Alcohol Use Disorders Identification Test (AUDIT). Validation procedures followed guidelines of the US Food and Drug Administration, the European Medicines Agency, and the Scientific Working Group for Forensic Toxicology. One hundred twenty subjects reported consuming alcohol during a 3-month period prior to enrollment. After taking the Thai-language version of AUDIT, subjects were divided on the basis of test scores into low, medium, and high-risk groups for chronic excessive alcohol use. The protocol satisfied the international standards for selectivity, specificity, accuracy, precision, and calibration curve. There was no significant matrix effect. Limits of detection and quantification (LOD/LOQ) were set at 15 pg of EtG per mg of hair. The protocol was not able to detect EtG in low-risk subjects (n = 38). Detection rates for medium-risk (n = 42) and high-risk subjects (n = 40) were 14.3% and 85%, respectively. The median of EtG concentration between these two groups were significantly different. Sensitivity and specificity were both more than 90% when EtG concentrations of high-risk subjects were compared with the 30 pg/mg cutoff recommended by the Society of Hair Testing (SoHT) for diagnosing chronic excessive alcohol consumption, based on an average ethanol daily intake greater than 60 g. The in-house protocol for EtG analysis in hair was validated according to international standards. The protocol is a useful tool for evaluating risk for chronic excessive drinking as defined by AUDIT scores. It strongly predicted the highest level of risk, although it was inadequate for assessing lower levels of risk.

  8. Validation of a school-based amblyopia screening protocol in a kindergarten population.

    PubMed

    Casas-Llera, Pilar; Ortega, Paula; Rubio, Inmaculada; Santos, Verónica; Prieto, María J; Alio, Jorge L

    2016-08-04

    To validate a school-based amblyopia screening program model by comparing its outcomes to those of a state-of-the-art conventional ophthalmic clinic examination in a kindergarten population of children between the ages of 4 and 5 years. An amblyopia screening protocol, which consisted of visual acuity measurement using Lea charts, ocular alignment test, ocular motility assessment, and stereoacuity with TNO random-dot test, was performed at school in a pediatric 4- to 5-year-old population by qualified healthcare professionals. The outcomes were validated in a selected group by a conventional ophthalmologic examination performed in a fully equipped ophthalmologic center. The ophthalmologic evaluation was used to confirm whether or not children were correctly classified by the screening protocol. The sensitivity and specificity of the test model to detect amblyopia were established. A total of 18,587 4- to 5-year-old children were subjected to the amblyopia screening program during the 2010-2011 school year. A population of 100 children were selected for the ophthalmologic validation screening. A sensitivity of 89.3%, specificity of 93.1%, positive predictive value of 83.3%, negative predictive value of 95.7%, positive likelihood ratio of 12.86, and negative likelihood ratio of 0.12 was obtained for the amblyopia screening validation model. The amblyopia screening protocol model tested in this investigation shows high sensitivity and specificity in detecting high-risk cases of amblyopia compared to the standard ophthalmologic examination. This screening program may be highly relevant for amblyopia screening at schools.

  9. EPA Traceability Protocol for Assay and Certification of Gaseous Calibration Standards (EPA/600/R-12/531, May 2012)

    EPA Science Inventory

    In 1997, the U.S. Environmental Protection Agency (EPA) in Research Triangle Park, North Carolina, revised its 1993 version of its traceability protocol for the assay and certification of compressed gas and permeation-device calibration standards. The protocol allows producers of...

  10. Intramedullary nailing in opening wedge high tibial osteotomy-in vitro test for validation of a method of fixation.

    PubMed

    Burchard, Rene; Katerla, Denise; Hammer, Marina; Pahlkötter, Anke; Soost, Christian; Dietrich, Gerhard; Ohrndorf, Arne; Richter, Wolfgang; Lengsfeld, Markus; Christ, Hans-Jürgen; Graw, Jan Adriaan; Fritzen, Claus-Peter

    2018-02-01

    Opening wedge high tibial osteotomy (HTO) as a treatment in unicompartimental osteoarthritis of the knee can significantly relieve pain and prevent or at least delay an early joint replacement. The fixation of the osteotomy has undergone development and refinements during the last years. The angle-stable plate fixator is currently one of the most commonly used plates in HTOs. The angular stable fixation between screws and the plate offers a high primary stability to retain the correction with early weight-bearing protocols. This surgical technique is performed as a standard of care and generally well tolerated by the patients. Nevertheless, some studies observed that many patients complained about discomfort related to the implant. Therefore, the stability of two different intramedullary nails, a short implant used in humeral fractures and a long device used in tibial fractures for stabilization in valgus HTOs, was investigated as an alternative fixation technique. The plate fixator was defined as reference standard. Nine synthetic tibia models were standardly osteotomized and stabilized by one of the fixation devices. Axial compression was realized using a special testing machine and two protocols were performed: a multi-step fatigue test and a load-to-failure test. Overall motion, medial, and lateral displacements were documented. Fractures always occurred at the lateral cortex. Axial cyclic loading up to 800 N was tolerated by all implants without failure. The tibia nail provided highest fatigue strength under the load-to-failure conditions. The results suggest that intramedullary nailing might be used as an alternative concept in HTO.

  11. Progress and Strategies for Testing of Materials for Solar Panels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurtz, Sarah

    Accelerated testing is key to confident launch of a new product. However, for new products like solar panels, the best approach is not always clear. The challenge for materials manufacturers is that test times can be long. Also, small-coupon testing may not predict the behavior in the full-size module, but testing of the full-size module is too expensive. As a result, solar panel test standards like IEC 61215 are useful, but are not sufficient. Material manufacturers have needed to define their own test protocols. This presentation will review some historical data (e.g., data show that manufacturers are making great progressmore » toward reducing encapsulant discoloration) and describe advances in material testing (for example, new techniques are being demonstrated on how to more quantitatively assess adhesion, detect tendency for delamination, and understand how encapsulant properties affect other properties like cracking of cells). The International PV Quality Assurance Task Force has been researching climate-specific weathering tests toward the goal of defining international standards that would simplify qualification and quality assurance testing for materials. The status of these tests and the strategies for how to organize these standards to best meet the needs of the industry will be discussed.« less

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bamberger, Judith A.; Piepel, Gregory F.; Enderlin, Carl W.

    Understanding how uncertainty manifests itself in complex experiments is important for developing the testing protocol and interpreting the experimental results. This paper describes experimental and measurement uncertainties, and how they can depend on the order of performing experimental tests. Experiments with pulse-jet mixers in tanks at three scales were conducted to characterize the performance of transient-developing periodic flows in Newtonian slurries. Other test parameters included the simulant, solids concentration, and nozzle exit velocity. Critical suspension velocity and cloud height were the metrics used to characterize Newtonian slurry flow associated with mobilization and mixing. During testing, near-replicate and near-repeat tests weremore » conducted. The experimental results were used to quantify the combined experimental and measurement uncertainties using standard deviations and percent relative standard deviations (%RSD) The uncertainties in critical suspension velocity and cloud height tend to increase with the values of these responses. Hence, the %RSD values are the more appropriate summary measure of near-replicate testing and measurement uncertainty.« less

  13. Integrated Data Collection Analysis (IDCA) Program - RDX Type II Class 5 Standard, Data Set 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sandstrom, Mary M.; Brown, Geoffrey W.; Preston, Daniel N.

    This document describes the results of the first reference sample material—RDX Type II Class 5—examined in the proficiency study for small-scale safety and thermal (SSST) testing of explosive materials for the Integrated Data Collection Analysis (IDCA) Program. The IDCA program is conducting proficiency testing on homemade explosives (HMEs). The reference sample materials are being studied to establish the accuracy of traditional explosives safety testing for each performing laboratory. These results will be used for comparison to results from testing HMEs. This effort, funded by the Department of Homeland Security (DHS), ultimately will put the issues of safe handling of thesemore » materials in perspective with standard military explosives. The results of the study will add SSST testing results for a broad suite of different HMEs to the literature, potentially suggest new guidelines and methods for HME testing, and possibly establish what are the needed accuracies in SSST testing to develop safe handling practices. Described here are the results for impact, friction, electrostatic discharge, and scanning calorimetry analysis of a reference sample of RDX Type II Class 5. The results from each participating testing laboratory are compared using identical test material and preparation methods wherever possible. Note, however, the test procedures differ among the laboratories. These results are then compared to historical data from various sources. The performers involved are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Air Force Research Laboratory/ RXQL (AFRL), Indian Head Division, Naval Surface Warfare Center, (IHD-NSWC), and Sandia National Laboratories (SNL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to understand how to compare results when test protocols are not identical.« less

  14. Intervention to Match Young Black Men and Transwomen Who Have Sex With Men or Transwomen to HIV Testing Options (All About Me): Protocol for a Randomized Controlled Trial.

    PubMed

    Koblin, Beryl; Hirshfield, Sabina; Chiasson, Mary Ann; Wilton, Leo; Usher, DaShawn; Nandi, Vijay; Hoover, Donald R; Frye, Victoria

    2017-12-19

    HIV testing is a critical component of HIV prevention and care. Interventions to increase HIV testing rates among young black men who have sex with men (MSM) and black transgender women (transwomen) are needed. Personalized recommendations for an individual's optimal HIV testing approach may increase testing. This randomized trial tests the hypothesis that a personalized recommendation of an optimal HIV testing approach will increase HIV testing more than standard HIV testing information. A randomized trial among 236 young black men and transwomen who have sex with men or transwomen is being conducted. Participants complete a computerized baseline assessment and are randomized to electronically receive a personalized HIV testing recommendation or standard HIV testing information. Follow-up surveys are conducted online at 3 and 6 months after baseline. The All About Me randomized trial was launched in June 2016. Enrollment is completed and 3-month retention is 92.4% (218/236) and has exceeded study target goals. The All About Me intervention is an innovative approach to increase HIV testing by providing a personalized recommendation of a person's optimal HIV testing approach. If successful, optimizing this intervention for mobile devices will widen access to large numbers of individuals. ClinicalTrial.gov NCT02834572; https://clinicaltrials.gov/ct2/show/NCT02834572 (Archived by WebCite at http://www.webcitation.org/6vLJWOS1B). ©Beryl Koblin, Sabina Hirshfield, Mary Ann Chiasson, Leo Wilton, DaShawn Usher, Vijay Nandi, Donald R Hoover, Victoria Frye. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 19.12.2017.

  15. Mobile/Modular BSL-4 Facilities for Meeting Restricted Earth Return Containment Requirements

    NASA Technical Reports Server (NTRS)

    Calaway, M. J.; McCubbin, F. M.; Allton, J. H.; Zeigler, R. A.; Pace, L. F.

    2017-01-01

    NASA robotic sample return missions designated Category V Restricted Earth Return by the NASA Planetary Protection Office require sample containment and biohazard testing in a receiving laboratory as directed by NASA Procedural Requirement (NPR) 8020.12D - ensuring the preservation and protection of Earth and the sample. Currently, NPR 8020.12D classifies Restricted Earth Return for robotic sample return missions from Mars, Europa, and Enceladus with the caveat that future proposed mission locations could be added or restrictions lifted on a case by case basis as scientific knowledge and understanding of biohazards progresses. Since the 1960s, sample containment from an unknown extraterrestrial biohazard have been related to the highest containment standards and protocols known to modern science. Today, Biosafety Level (BSL) 4 standards and protocols are used to study the most dangerous high-risk diseases and unknown biological agents on Earth. Over 30 BSL-4 facilities have been constructed worldwide with 12 residing in the United States; of theses, 8 are operational. In the last two decades, these brick and mortar facilities have cost in the hundreds of millions of dollars dependent on the facility requirements and size. Previous mission concept studies for constructing a NASA sample receiving facility with an integrated BSL-4 quarantine and biohazard testing facility have also been estimated in the hundreds of millions of dollars. As an alternative option, we have recently conducted an initial trade study for constructing a mobile and/or modular sample containment laboratory that would meet all BSL-4 and planetary protection standards and protocols at a faction of the cost. Mobile and modular BSL-2 and 3 facilities have been successfully constructed and deployed world-wide for government testing of pathogens and pharmaceutical production. Our study showed that a modular BSL-4 construction could result in approximately 90% cost reduction when compared to traditional construction methods without compromising the preservation of the sample or Earth.

  16. Sensitive Quantitative Assessment of Balance Disorders

    NASA Technical Reports Server (NTRS)

    Paloski, Willilam H.

    2007-01-01

    Computerized dynamic posturography (CDP) has become a standard technique for objectively quantifying balance control performance, diagnosing the nature of functional impairments underlying balance disorders, and monitoring clinical treatment outcomes. We have long used CDP protocols to assess recovery of sensory-motor function in astronauts following space flight. The most reliable indicators of post-flight crew performance are the sensory organization tests (SOTs), particularly SOTs 5 and 6, which are sensitive to changes in availability and/or utilization of vestibular cues. We have noted, however, that some astronauts exhibiting obvious signs of balance impairment after flight are able to score within clinical norms on these tests, perhaps as a result of adopting competitive strategies or by their natural skills at substituting alternate sensory information sources. This insensitivity of the CDP protocol could underestimate of the degree of impairment and, perhaps, lead to premature release of those crewmembers to normal duties. To improve the sensitivity of the CDP protocol we have introduced static and dynamic head tilt SOT trials into our protocol. The pattern of postflight recovery quantified by the enhanced CDP protocol appears to more aptly track the re-integration of sensory-motor function, with recovery time increasing as the complexity of sensory-motor/biomechanical task increases. The new CDP protocol therefore seems more suitable for monitoring post-flight sensory-motor recovery and for indicating to crewmembers and flight surgeons fitness for return to duty and/or activities of daily living. There may be classes of patients (e.g., athletes, pilots) having motivation and/or performance characteristics similar to astronauts whose sensory-motor treatment outcomes would also be more accurately monitored using the enhanced CDP protocol. Furthermore, the enhanced protocol may be useful in early detection of age-related balance disorders.

  17. A retrospective comparison of smart prep and test bolus multi-detector CT pulmonary angiography protocols

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Suckling, Tara; Smith, Tony; Reed, Warren

    2013-06-15

    Optimal arterial opacification is crucial in imaging the pulmonary arteries using computed tomography (CT). This poses the challenge of precisely timing data acquisition to coincide with the transit of the contrast bolus through the pulmonary vasculature. The aim of this quality assurance exercise was to investigate if a change in CT pulmonary angiography (CTPA) scanning protocol resulted in improved opacification of the pulmonary arteries. Comparison was made between the smart prep protocol (SPP) and the test bolus protocol (TBP) for opacification in the pulmonary trunk. A total of 160 CTPA examinations (80 using each protocol) performed between January 2010 andmore » February 2011 were assessed retrospectively. CT attenuation coefficients were measured in Hounsfield Units (HU) using regions of interest at the level of the pulmonary trunk. The average pixel value, standard deviation (SD), maximum, and minimum were recorded. For each of these variables a mean value was then calculated and compared for these two CTPA protocols. Minimum opacification of 200 HU was achieved in 98% of the TBP sample but only 90% of the SPP sample. The average CT attenuation over the pulmonary trunk for the SPP was 329 (SD = ±21) HU, whereas for the TBP it was 396 (SD = ±22) HU (P = 0.0017). The TBP also recorded higher maximum (P = 0.0024) and minimum (P = 0.0039) levels of opacification. This study has found that a TBP resulted in significantly better opacification of the pulmonary trunk than the SPP.« less

  18. Protocol for Atomic Oxygen Testing of Materials in Ground-Based Facilities. No. 2

    NASA Technical Reports Server (NTRS)

    Minton, Timothy K.

    1995-01-01

    A second version of standard guidelines is proposed for improving materials testing in ground-based atomic oxygen environments for the purpose of predicting the durability of the tested materials in low Earth orbit (LEO). Accompanying these guidelines are background information and notes about testing. Both the guidelines and the additional information are intended to aid users who wish to evaluate the potential hazard of atomic oxygen in LEO to a candidate space component without actually flying the component in space, and to provide a framework for more consistent atomic oxygen testing in the future.

  19. Roadmap for Testing and Validation of Electric Vehicle Communication Standards

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pratt, Richard M.; Tuffner, Francis K.; Gowri, Krishnan

    Vehicle to grid communication standards are critical to the charge management and interoperability among plug-in electric vehicles (PEVs), charging stations and utility providers. The Society of Automobile Engineers (SAE), International Organization for Standardization (ISO), International Electrotechnical Commission (IEC) and the ZigBee Alliance are developing requirements for communication messages and protocols. While interoperability standards development has been in progress for more than two years, no definitive guidelines are available for the automobile manufacturers, charging station manufacturers or utility backhaul network systems. At present, there is a wide range of proprietary communication options developed and supported in the industry. Recent work bymore » the Electric Power Research Institute (EPRI), in collaboration with SAE and automobile manufacturers, has identified performance requirements and developed a test plan based on possible communication pathways using power line communication (PLC). Though the communication pathways and power line communication technology options are identified, much work needs to be done in developing application software and testing of communication modules before these can be deployed in production vehicles. This paper presents a roadmap and results from testing power line communication modules developed to meet the requirements of SAE J2847/1 standard.« less

  20. Multi-institutional evaluation of end-to-end protocol for IMRT/VMAT treatment chains utilizing conventional linacs.

    PubMed

    Loughery, Brian; Knill, Cory; Silverstein, Evan; Zakjevskii, Viatcheslav; Masi, Kathryn; Covington, Elizabeth; Snyder, Karen; Song, Kwang; Snyder, Michael

    2018-03-20

    We conducted a multi-institutional assessment of a recently developed end-to-end monthly quality assurance (QA) protocol for external beam radiation therapy treatment chains. This protocol validates the entire treatment chain against a baseline to detect the presence of complex errors not easily found in standard component-based QA methods. Participating physicists from 3 institutions ran the end-to-end protocol on treatment chains that include Imaging and Radiation Oncology Core (IROC)-credentialed linacs. Results were analyzed in the form of American Association of Physicists in Medicine (AAPM) Task Group (TG)-119 so that they may be referenced by future test participants. Optically stimulated luminescent dosimeter (OSLD), EBT3 radiochromic film, and A1SL ion chamber readings were accumulated across 10 test runs. Confidence limits were calculated to determine where 95% of measurements should fall. From calculated confidence limits, 95% of measurements should be within 5% error for OSLDs, 4% error for ionization chambers, and 4% error for (96% relative gamma pass rate) radiochromic film at 3% agreement/3 mm distance to agreement. Data were separated by institution, model of linac, and treatment protocol (intensity-modulated radiation therapy [IMRT] vs volumetric modulated arc therapy [VMAT]). A total of 97% of OSLDs, 98% of ion chambers, and 93% of films were within the confidence limits; measurements were found outside these limits by a maximum of 4%, < 1%, and < 1%, respectively. Data were consistent despite institutional differences in OSLD reading equipment and radiochromic film calibration techniques. Results from this test may be used by clinics for data comparison. Areas of improvement were identified in the end-to-end protocol that can be implemented in an updated version. The consistency of our data demonstrates the reproducibility and ease-of-use of such tests and suggests a potential role for their use in broad end-to-end QA initiatives. Copyright © 2018 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  1. A unified in vitro evaluation for apatite-forming ability of bioactive glasses and their variants.

    PubMed

    Maçon, Anthony L B; Kim, Taek B; Valliant, Esther M; Goetschius, Kathryn; Brow, Richard K; Day, Delbert E; Hoppe, Alexander; Boccaccini, Aldo R; Kim, Ill Yong; Ohtsuki, Chikara; Kokubo, Tadashi; Osaka, Akiyoshi; Vallet-Regí, Maria; Arcos, Daniel; Fraile, Leandro; Salinas, Antonio J; Teixeira, Alexandra V; Vueva, Yuliya; Almeida, Rui M; Miola, Marta; Vitale-Brovarone, Chiara; Verné, Enrica; Höland, Wolfram; Jones, Julian R

    2015-02-01

    The aim of this study was to propose and validate a new unified method for testing dissolution rates of bioactive glasses and their variants, and the formation of calcium phosphate layer formation on their surface, which is an indicator of bioactivity. At present, comparison in the literature is difficult as many groups use different testing protocols. An ISO standard covers the use of simulated body fluid on standard shape materials but it does not take into account that bioactive glasses can have very different specific surface areas, as for glass powders. Validation of the proposed modified test was through round robin testing and comparison to the ISO standard where appropriate. The proposed test uses fixed mass per solution volume ratio and agitated solution. The round robin study showed differences in hydroxyapatite nucleation on glasses of different composition and between glasses of the same composition but different particle size. The results were reproducible between research facilities. Researchers should use this method when testing new glasses, or their variants, to enable comparison between the literature in the future.

  2. Demonstration/Validation of Environmentally-Preferable Coatings for Launch Facilities

    NASA Technical Reports Server (NTRS)

    Lewis, Pattie

    2011-01-01

    Kennedy Space Center (KSC) is responsible for a number of facilities/structures with metallic structural and non-structural components in a highly corrosive environment. Metals require periodic maintenance activity to guard against the insidious effects of corrosion and thus ensure that structures meet or exceed design or performance life. The standard practice for protecting metallic substrates in atmospheric environments is the application of an applied coating system. Applied coating systems work via a variety of methods (barrier, galvanic and/or inhibitor) and adhere to the substrate through a combination of chemical and physical bonds. Maintenance at KSC and other NASA Centers is governed by NASA-STD-50088 (Protective Coating of Carbon Steel, Stainless Steel, and Aluminum on Launch Structures, Facilities, and Ground Support Equipment) which establishes practices for the protective coating of ground support equipment and related facilities used by or for NASA programs and projects. The Standard is for the design of non-flight hardware used to support the operations of receiving, transportation, handling, assembly, inspection, test, checkout, service, and launch of space vehicles and payloads at NASA launch, landing, or retrieval sites. These criteria and practices contained within the Standard may be used for items used at the manufacturing, development, and test sites upstream of the launch, landing, or retrieval sites. The objective of this effort is to demonstrate and validate environmentally-preferable alternatives in accordance with NASA-STD-50088 and KSC requirements which can then be added to the Approved Products List. This Test Protocol contains the critical requirements and tests necessary to qualify alternatives for structural steel applications. These tests were derived from engineering, performance, and operational impact (supportability) requirements defined by a consensus of KSC participants. A Test Report will document the results of the testing as well as any test modifications made during the execution of the testing. Users of this Test Protocol should check the project's Test Report for additional test details or minor modifications that may have been necessary in the execution of the testing. The technical stakeholders will have agreed upon test procedures modifications documented in the Test Report.

  3. Standardized patient walkthroughs in the National Drug Abuse Treatment Clinical Trials Network: common challenges to protocol implementation.

    PubMed

    Fussell, Holly E; Kunkel, Lynn E; McCarty, Dennis; Lewy, Colleen S

    2011-09-01

    Training research staff to implement clinical trials occurring in community-based addiction treatment programs presents unique challenges. Standardized patient walkthroughs of study procedures may enhance training and protocol implementation. Examine and discuss cross-site and cross-study challenges of participant screening and data collection procedures identified during standardized patient walkthroughs of multi-site clinical trials. Actors portrayed clients and "walked through" study procedures with protocol research staff. The study completed 57 walkthroughs during implementation of 4 clinical trials. Observers and walkthrough participants identified three areas of concern (consent procedures, screening and assessment processes, and protocol implementation) and made suggestions for resolving the concerns. Standardized patient walkthroughs capture issues with study procedures previously unidentified with didactic training or unscripted rehearsals. Clinical trials within the National Drug Abuse Treatment Clinical Trials Network are conducted in addiction treatment centers that vary on multiple dimensions. Based on walkthrough observations, the national protocol team and local site leadership modify standardized operating procedures and resolve cross-site problems prior to recruiting study participants. The standardized patient walkthrough improves consistency across study sites and reduces potential site variation in study outcomes.

  4. Effects of scapulohumeral rehabilitation protocol on trunk control recovery in patients with subacute stroke: A pilot randomized controlled trial.

    PubMed

    Dell'Uomo, Daniela; Morone, Giovanni; Centrella, Antonio; Paolucci, Stefano; Caltagirone, Carlo; Grasso, Maria Grazia; Traballesi, Marco; Iosa, Marco

    2017-01-01

    Despite upper limb rehabilitation is widely investigated in patients with stroke, the effects of scapulohumeral rehabilitation on trunk stabillization are mainly unknown. To test the effects of scapulohumeral rehabilitation protocol on trunk control recovery in patients with subacute stroke. A pilot randomized controlled trial with two groups of 14 patients each one performing 20 minutes per day, 5 days a week, for 6 weeks in add on to standard therapy. Experimental group performed a specific scapulohumeral rehabilitation protocol aiming to improve trunk competencies whereas control group performed conventional arm rehabilitation. Clinical scale tests and accelerometric evaluations were performed pre- and post-treatment. Experimental groups showed better scores at discharge at Trunk impairment Scale (p < 0.001), Barthel Index (p = 0.024), Trunk Control Test (p = 0.002), Sitting Balance Scale (p = 0.002), but neither at Fugl-Meyer Scale (p = 0.194) nor Modified Ashworth Scale (p = 0.114). Accelerometric analysis showed higher stability of trunk for experimental group especially during static and dynamic items. The recovery of scapulohumeral functions also acts on trunk stabilization post-stroke.

  5. Human platelet lysate in mesenchymal stromal cell expansion according to a GMP grade protocol: a cell factory experience.

    PubMed

    Becherucci, Valentina; Piccini, Luisa; Casamassima, Serena; Bisin, Silvia; Gori, Valentina; Gentile, Francesca; Ceccantini, Riccardo; De Rienzo, Elena; Bindi, Barbara; Pavan, Paola; Cunial, Vanessa; Allegro, Elisa; Ermini, Stefano; Brugnolo, Francesca; Astori, Giuseppe; Bambi, Franco

    2018-05-02

    The use of platelet lysate (PL) for the ex-vivo expansion of mesenchymal stromal/stem cells (MSCs) was initially proposed by Doucet et al. in 2005, as an alternative to animal serum. Moreover, regulatory authorities discourage the use of fetal bovine serum (FBS) or other animal derivatives, to avoid risk of zoonoses and xenogeneic immune reactions. Even if many studies investigated PL composition, there still are some open issues related to its use in ex-vivo MSC expansion, especially according to good manufacturing practice (GMP) grade protocols. As an authorized cell factory, we report our experience using standardized PL produced by Azienda Ospedaliero Universitaria Meyer Transfusion Service for MSC expansion according to a GMP grade clinical protocol. As suggested by other authors, we performed an in-vitro test on MSCs versus MSCs cultured with FBS that still represents the best way to test PL batches. We compared 12 MSC batches cultured with DMEM 5% PL with similar batches cultured with DMEM 10% FBS, focusing on the MSC proliferation rate, MSC surface marker expression, MSC immunomodulatory and differentiation potential, and finally MSC relative telomere length. Results confirmed the literature data as PL increases cell proliferation without affecting the MSC immunophenotype, immunomodulatory potential, differentiation potential and relative telomere length. PL can be considered a safe alternative to FBS for ex-vivo expansion of MSC according to a GMP grade protocol. Our experience confirms the literature data: a large number of MSCs for clinical applications can be obtained by expansion with PL, without affecting the MSC main features. Our experience underlines the benefits of a close collaboration between the PL producers (transfusion service) and the end users (cell factory) in a synergy of skills and experiences that can lead to standardized PL production.

  6. Additional considerations are required when preparing a protocol for a systematic review with multiple interventions.

    PubMed

    Chaimani, Anna; Caldwell, Deborah M; Li, Tianjing; Higgins, Julian P T; Salanti, Georgia

    2017-03-01

    The number of systematic reviews that aim to compare multiple interventions using network meta-analysis is increasing. In this study, we highlight aspects of a standard systematic review protocol that may need modification when multiple interventions are to be compared. We take the protocol format suggested by Cochrane for a standard systematic review as our reference and compare the considerations for a pairwise review with those required for a valid comparison of multiple interventions. We suggest new sections for protocols of systematic reviews including network meta-analyses with a focus on how to evaluate their assumptions. We provide example text from published protocols to exemplify the considerations. Standard systematic review protocols for pairwise meta-analyses need extensions to accommodate the increased complexity of network meta-analysis. Our suggested modifications are widely applicable to both Cochrane and non-Cochrane systematic reviews involving network meta-analyses. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Mode II Interlaminar Fracture Toughness and Fatigue Characterization of a Graphite Epoxy Composite Material

    NASA Technical Reports Server (NTRS)

    O'Brien, T. Kevin; Johnston, William M.; Toland, Gregory J.

    2010-01-01

    Mode II interlaminar fracture toughness and delamination onset and growth characterization data were generated for IM7/8552 graphite epoxy composite materials from two suppliers for use in fracture mechanics analyses. Both the fracture toughness testing and the fatigue testing were conducted using the End-notched Flexure (ENF) test. The ENF test for mode II fracture toughness is currently under review by ASTM as a potential standard test method. This current draft ASTM protocol was used as a guide to conduct the tests on the IM7/8552 material. This report summarizes the test approach, methods, procedures and results of this characterization effort.

  8. Effectiveness of standardized approach versus usual care on physiotherapy treatment for patients submitted to alveolar bone graft: a pilot study.

    PubMed

    Vidotto, Laís Silva; Bigliassi, Marcelo; Alencar, Tatiane Romanini Rodrigues; Silva, Thaísa Maria Santos; Probst, Vanessa Suziane

    2015-07-01

    To compare the acute effects of a standardized physiotherapy protocol versus a typical non-standardized physiotherapy protocol on pain and performance of patients undergoing alveolar bone graft (ABG). Sixteen patients (9 males; 12 [11-13] years) with cleft lip and palate undergoing ABG were allocated into two groups: (1) experimental group--EG (standardized physiotherapy protocol); and (2) control group--CG (typical, non-standardized physiotherapy treatment). Range of motion, muscle strength, gait speed, and pain level were assessed prior to surgical intervention (PRE), as well as on the first, second, and third post-operative days (1st, 2nd, and 3rd PO, respectively). Recovery with respect to range of motion of hip flexion was more pronounced in the EG (64.6 ± 11.0°) in comparison to the CG (48.5 ± 17.7° on the 3rd PO; p < 0.05). In addition, less pain was observed in the EG (0 [0-0.2] versus 2 [0.7-3] in the CG on the 3rd PO; p < 0.05). A standardized physiotherapy protocol appears to be better than a non-standardized physiotherapy protocol for acute improvement of range of motion of hip flexion and for reducing pain in patients undergoing ABG.

  9. Optimized protocol for quantitative multiple reaction monitoring-based proteomic analysis of formalin-fixed, paraffin embedded tissues

    PubMed Central

    Kennedy, Jacob J.; Whiteaker, Jeffrey R.; Schoenherr, Regine M.; Yan, Ping; Allison, Kimberly; Shipley, Melissa; Lerch, Melissa; Hoofnagle, Andrew N.; Baird, Geoffrey Stuart; Paulovich, Amanda G.

    2016-01-01

    Despite a clinical, economic, and regulatory imperative to develop companion diagnostics, precious few new biomarkers have been successfully translated into clinical use, due in part to inadequate protein assay technologies to support large-scale testing of hundreds of candidate biomarkers in formalin-fixed paraffin embedded (FFPE) tissues. While the feasibility of using targeted, multiple reaction monitoring-mass spectrometry (MRM-MS) for quantitative analyses of FFPE tissues has been demonstrated, protocols have not been systematically optimized for robust quantification across a large number of analytes, nor has the performance of peptide immuno-MRM been evaluated. To address this gap, we used a test battery approach coupled to MRM-MS with the addition of stable isotope labeled standard peptides (targeting 512 analytes) to quantitatively evaluate the performance of three extraction protocols in combination with three trypsin digestion protocols (i.e. 9 processes). A process based on RapiGest buffer extraction and urea-based digestion was identified to enable similar quantitation results from FFPE and frozen tissues. Using the optimized protocols for MRM-based analysis of FFPE tissues, median precision was 11.4% (across 249 analytes). There was excellent correlation between measurements made on matched FFPE and frozen tissues, both for direct MRM analysis (R2 = 0.94) and immuno-MRM (R2 = 0.89). The optimized process enables highly reproducible, multiplex, standardizable, quantitative MRM in archival tissue specimens. PMID:27462933

  10. Wound-healing outcomes using standardized assessment and care in clinical practice.

    PubMed

    Bolton, Laura; McNees, Patrick; van Rijswijk, Lia; de Leon, Jean; Lyder, Courtney; Kobza, Laura; Edman, Kelly; Scheurich, Anne; Shannon, Ron; Toth, Michelle

    2004-01-01

    Wound-healing outcomes applying standardized protocols have typically been measured within controlled clinical trials, not natural settings. Standardized protocols of wound care have been validated for clinical use, creating an opportunity to measure the resulting outcomes. Wound-healing outcomes were explored during clinical use of standardized validated protocols of care based on patient and wound assessments. This was a prospective multicenter study of wound-healing outcomes management in real-world clinical practice. Healing outcomes from March 26 to October 31, 2001, were recorded on patients in 3 long-term care facilities, 1 long-term acute care hospital, and 12 home care agencies for wounds selected by staff to receive care based on computer-generated validated wound care algorithms. After diagnosis, wound dimensions and status were assessed using a tool adapted from the Pressure Sore Status Toolfor use on all wounds. Wound, ostomy, and continence nursing professionals accessed consistent protocols of care, via telemedicine in home care or paper forms in long-term care. A physician entered assessments into a desktop computer in the wound clinic. Based on evidence that healing proceeds faster with fewer infections in environments without gauze, the protocols generally avoided gauze dressings. Most of the 767 wounds selected to receive the standardized-protocols of care were stage III-IV pressure ulcers (n = 373; mean healing time 62 days) or full-thickness venous ulcers (n = 124; mean healing time 57 days). Partial-thickness wounds healed faster than same-etiology full-thickness wounds. These results provide benchmarks for natural-setting healing outcomes and help to define and address wound care challenges. Outcomes primarily using nongauze protocols of care matched or surpassed best previously published results on similar wounds using gauze-based protocols of care, including protocols applying gauze impregnated with growth factors or other agents.

  11. Evaluation of Vitamin D Standardization Program protocols for standardizing serum 25-hydroxyvitamin D data: a case study of the program's potential for national nutrition and health surveys12345

    PubMed Central

    Cashman, Kevin D; Kiely, Mairead; Kinsella, Michael; Durazo-Arvizu, Ramón A; Tian, Lu; Zhang, Yue; Lucey, Alice; Flynn, Albert; Gibney, Michael J; Vesper, Hubert W; Phinney, Karen W; Coates, Paul M; Picciano, Mary F; Sempos, Christopher T

    2013-01-01

    Background: The Vitamin D Standardization Program (VDSP) has developed protocols for standardizing procedures of 25-hydroxyvitamin D [25(OH)D] measurement in National Health/Nutrition Surveys to promote 25(OH)D measurements that are accurate and comparable over time, location, and laboratory procedure to improve public health practice. Objective: We applied VDSP protocols to existing ELISA-derived serum 25(OH)D data from the Irish National Adult Nutrition Survey (NANS) as a case-study survey and evaluated their effectiveness by comparison of the protocol-projected estimates with those from a reanalysis of survey serums by using liquid chromatography–tandem mass spectrometry (LC–tandem MS). Design: The VDSP reference system and protocols were applied to ELISA-based serum 25(OH)D data from the representative NANS sample (n = 1118). A reanalysis of 99 stored serums by using standardized LC–tandem MS and resulting regression equations yielded predicted standardized serum 25(OH)D values, which were then compared with LC–tandem MS reanalyzed values for all serums. Results: Year-round prevalence rates for serum 25(OH)D concentrations <30, <40, and <50 nmol/L were 6.5%, 21.9%, and 40.0%, respectively, via original ELISA measurements and 11.4%, 25.3%, and 43.7%, respectively, when VDSP protocols were applied. Differences in estimates at <30- and <40-nmol/L thresholds, but not at the <50-nmol/L threshold, were significant (P < 0.05). A reanalysis of all serums by using LC–tandem MS confirmed prevalence estimates as 11.2%, 27.2%, and 45.0%, respectively. Prevalences of serum 25(OH)D concentrations >125 nmol/L were 1.2%, 0.3%, and 0.6% by means of ELISA, VDSP protocols, and LC–tandem MS, respectively. Conclusion: VDSP protocols hold a major potential for national nutrition and health surveys in terms of the standardization of serum 25(OH)D data. PMID:23615829

  12. Depression screening and management among adolescents in primary care: factors associated with best practice.

    PubMed

    Taliaferro, Lindsay A; Hetler, Joel; Edwall, Glenace; Wright, Catherine; Edwards, Anne R; Borowsky, Iris W

    2013-06-01

    To compare depression identification and management perceptions and practices between professions and disciplines in primary care and examine factors that increase the likelihood of administering a standardized depression screening instrument, asking about patients' depressive symptoms, and using best practice when managing depressed adolescents. Data came from an online survey of clinicians in Minnesota (20% response rate). Analyses involved bivariate tests and linear regressions. The analytic sample comprised 260 family medicine physicians, 127 pediatricians, 96 family nurse practitioners, and 54 pediatric nurse practitioners. Overall, few differences emerged between physicians and nurse practitioners or family and pediatric clinicians regarding addressing depression among adolescents. Two factors associated with administering a standardized instrument included having clear protocols for follow-up after depression screening and feeling better prepared to address depression among adolescents. Enhancing clinicians' competence to address depression and developing postscreening protocols could help providers implement universal screening in primary care.

  13. Novel methodology to isolate microplastics from vegetal-rich samples.

    PubMed

    Herrera, Alicia; Garrido-Amador, Paloma; Martínez, Ico; Samper, María Dolores; López-Martínez, Juan; Gómez, May; Packard, Theodore T

    2018-04-01

    Microplastics are small plastic particles, globally distributed throughout the oceans. To properly study them, all the methodologies for their sampling, extraction, and measurement should be standardized. For heterogeneous samples containing sediments, animal tissues and zooplankton, several procedures have been described. However, definitive methodologies for samples, rich in algae and plant material, have not yet been developed. The aim of this study was to find the best extraction protocol for vegetal-rich samples by comparing the efficacies of five previously described digestion methods, and a novel density separation method. A protocol using 96% ethanol for density separation was better than the five digestion methods tested, even better than using H 2 O 2 digestion. As it was the most efficient, simple, safe and inexpensive method for isolating microplastics from vegetal rich samples, we recommend it as a standard separation method. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. Implementation and Evaluation of Four Interoperable Open Standards for the Internet of Things

    PubMed Central

    Jazayeri, Mohammad Ali; Liang, Steve H. L.; Huang, Chih-Yuan

    2015-01-01

    Recently, researchers are focusing on a new use of the Internet called the Internet of Things (IoT), in which enabled electronic devices can be remotely accessed over the Internet. As the realization of IoT concept is still in its early stages, manufacturers of Internet-connected devices and IoT web service providers are defining their proprietary protocols based on their targeted applications. Consequently, IoT becomes heterogeneous in terms of hardware capabilities and communication protocols. Addressing these heterogeneities by following open standards is a necessary step to communicate with various IoT devices. In this research, we assess the feasibility of applying existing open standards on resource-constrained IoT devices. The standard protocols developed in this research are OGC PUCK over Bluetooth, TinySOS, SOS over CoAP, and OGC SensorThings API. We believe that by hosting open standard protocols on IoT devices, not only do the devices become self-describable, self-contained, and interoperable, but innovative applications can also be easily developed with standardized interfaces. In addition, we use memory consumption, request message size, response message size, and response latency to benchmark the efficiency of the implemented protocols. In all, this research presents and evaluates standard-based solutions to better understand the feasibility of applying existing standards to the IoT vision. PMID:26402683

  15. Development of a cross-disciplinary continuous insulin infusion protocol for non-critically ill patients in a French university hospital.

    PubMed

    Bernard, Lise; Roche, Béatrice; Batisse, Marie; Maqdasy, Salwan; Terral, Daniel; Sautou, Valérie; Tauveron, Igor

    2016-10-01

    In non-critically ill patients, the use of an insulin syringe pump allows the management of temporary situations during which other therapies cannot be used (failure of subcutaneous injections, awaiting advice from the diabetes team, emergency situations, prolonged corticosteroid therapy, initiation of an artificial nutrition, need for a fasting status, etc.). To manage the risks related to this «never event», the use of a standard validated protocol for insulin administration and monitoring is an essential prerequisite. To this end, a multidisciplinary approach is recommended. With the support of our subcommission «Endocrinology-Diabetology», we proceeded with a «step-by-step process» to create such a standardized protocol: (1) review of all existing protocols in our hospital; (2) overview of the literature data concerning insulin infusion protocols developed by multidisciplinary teams in France and abroad; (3) development of a standardized protocol for non-intensive care unit patients, respecting the current recommendations and adapting it to the working habits of health teams; and (4) validation of the protocol Two protocols based on the same structure but adapted to the health status of the patient have been developed. The protocols are divided in to three parts: (1) golden rules to make the use of the protocol appropriate and safe; (2) the algorithm (a double entry table) corresponding to a dynamic adaptation of insulin doses, clearly defining the target and the 'at risk situations'; and (3) practical aspects of the protocol: preparation of the syringe, treatment initiation and traceability. The protocols have been validated by the institution. Our standardized insulin infusion protocol is simple, easy to implement, safe and is likely to be applicable in diverse care units. However, the efficiency, safety and the workability of our protocols have to be clinically evaluated. © 2016 John Wiley & Sons, Ltd.

  16. Disinfectant wipes are appropriate to control microbial bioburden from surfaces: use of a new ASTM standard test protocol to demonstrate efficacy.

    PubMed

    Sattar, S A; Bradley, C; Kibbee, R; Wesgate, R; Wilkinson, M A C; Sharpe, T; Maillard, J-Y

    2015-12-01

    The use of disinfectant pre-soaked wipes (DPW) to decontaminate high-touch environmental surfaces (HTES) by wiping is becoming increasingly widespread in the healthcare environment. However, DPW are rarely tested using conditions simulating their field use, and the label claims of environmental surface disinfectants seldom include wiping action. To evaluate the new E2967-15 standard test specific to wipes, particularly their ability to decontaminate surfaces and to transfer acquired contamination to clean surfaces. ASTM Standard E2967-15 was used by three independent laboratories to test the efficacy of five types of commercially available wipe products. All data generated were pulled together, and reproducibility and repeatability of the standard were measured. All the commercial DPW tested achieved a >4log10 (>99.99%) reduction in colony-forming units (CFU) of Staphylococcus aureus and Acinetobacter baumanii with 10s of wiping, but only one DPW containing 0.5% accelerated H2O2 prevented the transfer of bacteria to another surface. This newly introduced standard method represents a significant advance in assessing DPW for microbial decontamination of HTES, and should greatly assist research and development, and in making more relevant and reliable claims on marketed DPW. Copyright © 2015. Published by Elsevier Ltd.

  17. Satellite Communications Using Commercial Protocols

    NASA Technical Reports Server (NTRS)

    Ivancic, William D.; Griner, James H.; Dimond, Robert; Frantz, Brian D.; Kachmar, Brian; Shell, Dan

    2000-01-01

    NASA Glenn Research Center has been working with industry, academia, and other government agencies in assessing commercial communications protocols for satellite and space-based applications. In addition, NASA Glenn has been developing and advocating new satellite-friendly modifications to existing communications protocol standards. This paper summarizes recent research into the applicability of various commercial standard protocols for use over satellite and space- based communications networks as well as expectations for future protocol development. It serves as a reference point from which the detailed work can be readily accessed. Areas that will be addressed include asynchronous-transfer-mode quality of service; completed and ongoing work of the Internet Engineering Task Force; data-link-layer protocol development for unidirectional link routing; and protocols for aeronautical applications, including mobile Internet protocol routing for wireless/mobile hosts and the aeronautical telecommunications network protocol.

  18. Anthropometric protocols for the construction of new international fetal and newborn growth standards: the INTERGROWTH-21st Project.

    PubMed

    Cheikh Ismail, L; Knight, H E; Bhutta, Z; Chumlea, W C

    2013-09-01

    The primary aim of the INTERGROWTH-21(st) Project is to construct new, prescriptive standards describing optimal fetal and preterm postnatal growth. The anthropometric measurements include the head circumference, recumbent length and weight of the infants, and the stature and weight of the parents. In such a large, international, multicentre project, it is critical that all study sites follow standardised protocols to ensure maximal validity of the growth and nutrition indicators used. This paper describes, in detail, the selection of anthropometric personnel, equipment, and measurement and calibration protocols used to construct the new standards. Implementing these protocols at each study site ensures that the anthropometric data are of the highest quality to construct the international standards. © 2013 Royal College of Obstetricians and Gynaecologists.

  19. Performance of the Colson MAM BP 3AA1-2 automatic blood pressure monitor according to the European Society of Hypertension validation protocol.

    PubMed

    Pereira, Telmo; Maldonado, João

    2005-11-01

    To evaluate the performance of the Colson MAM BP 3AA1-2 oscillometric automatic blood pressure monitor according to the validation protocol of the European Society of Hypertension, testing its suitability for self-measurement of blood pressure. The performance of the device was assessed in relation to various clinical variables, including age, gender, body mass index, arm circumference and arterial stiffness. 33 subjects (15 men and 18 women), with a mean age of 47 +/- 10 years, were studied according to the procedures laid down in the European Society of Hypertension validation protocol. Sequential same-arm blood pressure measurements were made, alternating between a mercury standard and the automatic device. The differences among the test-control measurements were assessed and divided into categorization zones of 5, 10 and 15 mmHg discrepancy. Aortic pulse wave velocity was assessed in all subjects with a Complior device (Colson, Paris). The Colson MAM BP 3AA1-2 passed all three phases of the protocol for both systolic and diastolic blood pressure. The mean differences between the test and control measurements were -1.0 +/- 5.0 mmHg for systolic blood pressure and -1.1 +/- 4.1 mmHg for diastolic blood pressure. Both standard deviations are well below the 8 mmHg limit proposed by the Association for the Advancement of Medical Instrumentation. The predictive value of various clinical variables for the discrepancies was assessed by a regression model analysis, with no variable being found that independently undermined the performance of the monitor. In another regression analysis, we found a similar relation between test and control blood pressures and aortic pulse wave velocity, a widely recognized and validated index of target organ damage. These data show that the Colson MAM BP 3AA1-2 satisfies the quality requirements proposed by the European Society of Hypertension, demonstrating its suitability for inclusion in integrated programs of clinical surveillance based on self-measurement of blood pressure. The uniformity of its performance over a wide spectrum of clinical characteristics and the relation found with pulse wave velocity further reinforce its clinical validity.

  20. Impact of a bladder scan protocol on discharge efficiency within a care pathway for ambulatory inguinal herniorraphy.

    PubMed

    Antonescu, I; Baldini, G; Watson, D; Kaneva, P; Fried, G M; Khwaja, K; Vassiliou, M C; Carli, F; Feldman, L S

    2013-12-01

    Postoperative urinary retention (POUR) is a common complication of ambulatory inguinal herniorraphy, with an incidence reaching 38%, and many surgeons require patients to void before discharge. This study aimed to assess whether the implementation of a bladder scan-based voiding protocol reduces the time until discharge after ambulatory inguinal herniorraphy without increasing the rate of POUR. As part of a perioperative care pathway, a protocol was implemented to standardize decision making after elective inguinal hernia repair (February 2012). Patients were assessed with a bladder scan, and those with <600 mL of urine were discharged home, whereas those with more than 600 mL of urine had an in-and-out catheterization before discharge. The patients received written information about urinary symptoms and instructions to present to the emergency department if they were unable to void at home. An audit of scheduled outpatient inguinal hernia repairs between October 2011 and July 2012 was performed. Comparisons were made using the t test, Fisher's exact test, and Wilcoxon rank sum test where appropriate. Statistical significance was defined a priori as a p value lower than 0.05. During the study period, 124 patients underwent hernia repair: 60 before and 64 after implementation of the protocol. The findings showed no significant differences in patient characteristics, laparoscopic approach (35 vs. 33%; p = 0.80), proportion receiving general anesthesia (70 vs. 73%; p = 0.67), or amount of intravenous fluids given (793 vs. 663 mL; p = 0.07). The proportion of patients voiding before discharge was higher after protocol implementation (73 vs. 89%; p = 0.02). The protocol had no impact on median time to discharge (190 vs. 205 min; p = 0.60). Only one patient in each group presented to the emergency department with POUR (2%). After ambulatory inguinal herniorraphy, implementation of a bladder scan-based voiding protocol did not result in earlier discharge. The incidence of POUR was lower than reported in the literature.

  1. Defense switched network technology and experiments program

    NASA Astrophysics Data System (ADS)

    Weinstein, C. J.

    1983-09-01

    This report documents work performed during FY 1983 on the DCA-sponsored Defense Switched Network Technology and Experiments Program. The areas of work reported are: (1) development of routing algorithms for application in the Defense Switched Network (DSN); (2) instrumentation and integration of the Experimental Integrated Switched Network (EISN) test facility; (3) development and test of data communication techniques using DoD-standard data protocols in an integrated voice/data network; and (4) EISN system coordination and experiment planning.

  2. Magnetic Resonance Imaging Assessment of the Velopharyngeal Mechanism at Rest and during Speech in Chinese Adults and Children

    ERIC Educational Resources Information Center

    Tian, Wei; Yin, Heng; Redett, Richard J.; Shi, Bing; Shi, Jin; Zhang, Rui; Zheng, Qian

    2010-01-01

    Purpose: Recent applications of the magnetic resonance imaging (MRI) technique introduced accurate 3-dimensional measurements of the velopharyngeal mechanism. Further standardization of the data acquisition and analysis protocol was successfully applied to imaging adults at rest and during phonation. This study was designed to test and modify a…

  3. Volcanic Ash Soils: Sustainable Soil Management Practices, With Examples of Harvest Effects and Root Disease Trends

    Treesearch

    Mike Curran; Pat Green; Doug Maynard

    2007-01-01

    Sustainability protocols recognize forest soil disturbance as an important issue at national and international levels. At regional levels continual monitoring and testing of standards, practices, and effects are necessary for successful implementation of sustainable soil management. Volcanic ash-cap soils are affected by soil disturbance and changes to soil properties...

  4. 24 CFR 3285.402 - Ground anchor installations.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... least equivalent to that provided by a coating of zinc on steel of not less than 0.30 oz./ft.2 of... recognized testing protocol. (2) Tie-down straps. A 11/4 inch x 0.035 inch or larger steel strapping conforming to ASTM D 3953—97, Standard Specification for Strapping, Flat Steel and Seals (incorporated by...

  5. 49 CFR Appendix F to Part 240 - Medical Standards Guidelines

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... used as signals in the railroad industry. The acceptable test methods are shown in the left hand column... these protocols, the person conducting the examination should be aware that railroad signals do not always occur in the same sequence and that “yellow signals” do not always appear to be the same. It is...

  6. 49 CFR Appendix F to Part 240 - Medical Standards Guidelines

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... used as signals in the railroad industry. The acceptable test methods are shown in the left hand column... these protocols, the person conducting the examination should be aware that railroad signals do not always occur in the same sequence and that “yellow signals” do not always appear to be the same. It is...

  7. 49 CFR Appendix F to Part 240 - Medical Standards Guidelines

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... used as signals in the railroad industry. The acceptable test methods are shown in the left hand column... these protocols, the person conducting the examination should be aware that railroad signals do not always occur in the same sequence and that “yellow signals” do not always appear to be the same. It is...

  8. Germination and early plant development of ten plant species exposed to titanium dioxide and cerium oxide nanoparticles

    EPA Science Inventory

    Ten agronomic plant species were exposed to different concentrations of nano titanium dioxide (nTiO2) or nano cerium oxide (nCeO2) (0, 250, 500 and 1000 mg/L) to examine potential effects on germination and early seedling development. We modified a standard test protocol develop...

  9. PROGRESS TOWARDS DEVELOPMENT OF AN AMPHIBIAN-BASED THYROID SCREENING ASSAY USING XENOPUS LAEVIS: ORGANISMAL AND THYROIDAL RESPONSES TO THE MODEL COMPOUNDS 6-PROPYLTHIOURACIL, METHIMAZOLE, AND THYROXINE.

    EPA Science Inventory

    The data presented in this manuscript specifically addresses the development and standardization needs associated with an amphibian thyroid axis screening assay. A protocol for an amphibian growth and reproduction test has been requested by the Office of Science Council and Polic...

  10. Prospective evaluation of a new protocol for the provisional use of perfusion imaging with exercise stress testing.

    PubMed

    Duvall, W Lane; Savino, John A; Levine, Elliot J; Hermann, Luke K; Croft, Lori B; Henzlova, Milena J

    2015-02-01

    Previous literature suggests that myocardial perfusion imaging (MPI) adds little to the prognosis of patients who exercise >10 metabolic equivalents (METs) during stress testing. With this in mind, we prospectively tested a provisional injection protocol in emergency department (ED) patients presenting for the evaluation of chest pain in which a patient would not receive an injection of radioisotope if adequate exercise was achieved without symptoms and a negative ECG response. All patients who presented to the ED over a 5-year period who were referred for stress testing as part of their ED evaluation were included. Patients considered for a provisional protocol were: exercise stress, age <65 years, no known coronary artery disease, and an interpretable rest ECG. Criteria for not injecting included a maximal predicted heart rate ≥85%, ≥10 METs of exercise, no anginal symptoms during stress, and no ECG changes. Groups were compared based on stress test results, all-cause and cardiac mortality, follow-up cardiac testing, subsequent revascularization, and cost. A total of 965 patients were eligible with 192 undergoing exercise-only and 773 having perfusion imaging. After 41.6 ± 19.6 months of follow-up, all-cause mortality was similar in the exercise-only versus the exercise plus imaging group (2.6% vs. 2.1%, p = 0.59). There were no cardiac deaths in the exercise-only group. At 1 year there was no difference in the number of repeat functional stress tests (1.6% vs. 2.1%, p = 0.43), fewer angiograms (0% vs. 4.0%, p = 0.002), and a significantly lower cost ($65 ± $332 vs $506 ± $1,991, p = 0.002; values are in US dollars) in the exercise-only group. The radiation exposure in the exercise plus imaging group was 8.4 ± 2.1 mSv. A provisional injection protocol has a very low mortality, few follow-up diagnostic tests, and lower cost compared to standard imaging protocols. If adopted it would decrease radiation exposure, save time and decrease health-care costs without jeopardizing prognosis.

  11. Comparing the effects of whole-body vibration to standard exercise in ambulatory people with Multiple Sclerosis: a randomised controlled feasibility study.

    PubMed

    Uszynski, Marcin Kacper; Purtill, Helen; Donnelly, Alan; Coote, Susan

    2016-07-01

    This study aimed firstly to investigate the feasibility of the study protocol and outcome measures, secondly to obtain data in order to inform the power calculations for a larger randomised controlled trial, and finally to investigate if whole-body vibration (WBV) is more effective than the same duration and intensity of standard exercises (EXE) in people with Multiple Sclerosis (PwMS). Randomised controlled feasibility study. Outpatient MS centre. Twenty seven PwMS (age mean (SD) 48.1 (11.2)) with minimal gait impairments. Twelve weeks of WBV or standard EXE, three times weekly. Participants were measured with isokinetic muscle strength, vibration threshold, Timed Up and Go test (TUG), Mini-BESTest (MBT), 6 Minute Walk test (6MWT), Multiple Sclerosis Impact Scale 29 (MSIS 29), Modified Fatigue Impact Scale (MFIS) and Verbal Analogue scale for sensation (VAS) pre and post 12 week intervention. WBV intervention was found feasible with low drop-out rate (11.1%) and high compliance (90%). Data suggest that a sample of 52 in each group would be sufficient to detect a moderate effect size, with 80% power and 5% significance for 6 minute walk test. Large effect sizes in favour of standard exercise were found for vibration threshold at 5th metatarsophalangeal joint and heel (P=0.014, r= 0.5 and P=0.005, r=0.56 respectively). No between group differences were found for muscle strength, balance or gait (P>0.05). Data suggest that the protocol is feasible, there were no adverse effects. A trial including 120 people would be needed to detect an effect on walking endurance. © The Author(s) 2015.

  12. Care of pediatric tracheostomy in the immediate postoperative period and timing of first tube change.

    PubMed

    Lippert, Dylan; Hoffman, Matthew R; Dang, Phat; McMurray, J Scott; Heatley, Diane; Kille, Tony

    2014-12-01

    To analyze the safety of a standardized pediatric tracheostomy care protocol in the immediate postoperative period and its impact on tracheostomy related complications. Retrospective case series. Pediatric patients undergoing tracheotomy from February 2010-February 2014. In 2012, a standardized protocol was established regarding postoperative pediatric tracheostomy care. This protocol included securing newly placed tracheostomy tubes using a foam strap with hook and loop fastener rather than twill ties, placing a fresh drain sponge around the tracheostomy tube daily, and performing the first tracheostomy tube change on postoperative day 3 or 4. Outcome measures included rate of skin breakdown and presence of a mature stoma allowing for a safe first tracheostomy tube change. Two types of tracheotomy were performed based on patient age: standard pediatric tracheotomy and adult-style tracheotomy with a Bjork flap. Patients were analyzed separately based on age and the type of tracheotomy performed. Thirty-seven patients in the pre-protocol group and 35 in the post-protocol group were analyzed. The rate of skin breakdown was significantly lower in the post-protocol group (standard: p=0.0048; Bjork flap: p=0.0003). In the post-protocol group, all tube changes were safely accomplished on postoperative day three or four, and the stomas were deemed to be adequately matured to do so in all cases. A standardized postoperative pediatric tracheostomy care protocol resulted in decreased rates of skin breakdown and demonstrated that pediatric tracheostomy tubes can be safely changed as early as 3 days postoperatively. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  13. Inter-laboratory validation of bioaccessibility testing for metals.

    PubMed

    Henderson, Rayetta G; Verougstraete, Violaine; Anderson, Kim; Arbildua, José J; Brock, Thomas O; Brouwers, Tony; Cappellini, Danielle; Delbeke, Katrien; Herting, Gunilla; Hixon, Greg; Odnevall Wallinder, Inger; Rodriguez, Patricio H; Van Assche, Frank; Wilrich, Peter; Oller, Adriana R

    2014-10-01

    Bioelution assays are fast, simple alternatives to in vivo testing. In this study, the intra- and inter-laboratory variability in bioaccessibility data generated by bioelution tests were evaluated in synthetic fluids relevant to oral, inhalation, and dermal exposure. Using one defined protocol, five laboratories measured metal release from cobalt oxide, cobalt powder, copper concentrate, Inconel alloy, leaded brass alloy, and nickel sulfate hexahydrate. Standard deviations of repeatability (sr) and reproducibility (sR) were used to evaluate the intra- and inter-laboratory variability, respectively. Examination of the sR:sr ratios demonstrated that, while gastric and lysosomal fluids had reasonably good reproducibility, other fluids did not show as good concordance between laboratories. Relative standard deviation (RSD) analysis showed more favorable reproducibility outcomes for some data sets; overall results varied more between- than within-laboratories. RSD analysis of sr showed good within-laboratory variability for all conditions except some metals in interstitial fluid. In general, these findings indicate that absolute bioaccessibility results in some biological fluids may vary between different laboratories. However, for most applications, measures of relative bioaccessibility are needed, diminishing the requirement for high inter-laboratory reproducibility in absolute metal releases. The inter-laboratory exercise suggests that the degrees of freedom within the protocol need to be addressed. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Minimizing losses by variational counter-diabatic driving

    NASA Astrophysics Data System (ADS)

    Sels, Dries; Polkovnikov, Anatoli

    Despite the time-reversal symmetry of the microscopic dynamics of isolated systems, losses are ubiquitous in any process that tries to manipulate them. Whether it's the heat produced in a car engine or the decoherence of a qubit, all losses arise from our lack of control on the microscopic degrees of freedom of the system. Counter-diabatic driving protocols were proposed as a means to do fast changes in the Hamiltonian without exciting transitions. Such driving in principle allows one to realize arbitrarily fast annealing protocols or implement fast dissipationless driving, circumventing standard adiabatic limitations requiring infinitesimally slow rates. These ideas were tested and used both experimentally and theoretically in small systems, but in larger chaotic systems it is known that exact counter-diabatic protocols do not exist. Here we will present a simple variational approach allowing one to find best physical counter-diabatic protocols. We will show that, while they do not get rid of all transitions, the variational protocols are able to significantly reduce the induced fluctuations in the system. D.S. acknowledges support by the FWO.

  15. Experience over fifteen years with a protocol for predictive testing for Huntington disease.

    PubMed

    Dufrasne, Suzanne; Roy, Madeleine; Galvez, Maria; Rosenblatt, David S

    2011-04-01

    To compile a comprehensive profile of the participants who had predictive testing from Huntington disease (HD) between 1994 and 2008 in Montreal, Canada. This is a retrospective cohort study. The predictive testing protocol consisted of a telephone interview to give information about predictive testing and collect demographic data; a psychological assessment and counseling session; a session focused on medical and family history of HD; a session reserved for genetic counseling; a session where results were given to participants; and a follow-up telephone interview. A total of 181 applicants requested presymptomatic testing. 135 applicants (77 women and 58 men) completed the protocol and received test results while 40 withdrew. Of the latter, 3 manifested symptoms of the disease and were referred to a neurologist or psychiatrist, and 3 had previously been tested by linkage analysis. Participants usually mentioned more than one reason for requesting predictive testing but the most frequent was to put an end to uncertainty concerning their risk of illness. The proportion of positive and negatives test results was 40% and 54.1% respectively, significantly different from the expected 50% (p<0.01). Prenatal testing was not frequently requested. All the participants expressed satisfaction regarding their decision to be tested. None to our knowledge had a catastrophic reaction (major depressive disorder or psychiatric hospitalization, declared suicide attempt or suicide). Our study highlights that preparation for receiving test results is a psychologically complex process for which appropriate support in a timely fashion is critical. We feel that a cautious and ethical case by case approach remains essential and that high standards of testing should be maintained because of the far reaching impact of test results. Copyright © 2010 Elsevier Inc. All rights reserved.

  16. Epidemiology of alcohol and other drug use among motor vehicle crash victims admitted to a trauma center.

    PubMed

    Walsh, J Michael; Flegel, Ron; Cangianelli, Leo A; Atkins, Randolph; Soderstrom, Carl A; Kerns, Timothy J

    2004-09-01

    The objectives of this research were to (1) determine the incidence and prevalence of alcohol and other drug use among motor vehicle crash (MVC) victims admitted to a regional Level-I trauma center, and (2) to examine the utility of using a rapid point-of-collection (POC) drug-testing device to identify MVC patients with drug involvement. Blood and urine specimens were routinely collected per clinical protocol for each MVC victim at the time of admission. Blood alcohol concentration (BAC) levels were determined per standard clinical protocol. Clinical urine specimens were routinely split so that a POC drug-testing device for the detection of commonly abused drugs (Marijuana, Cocaine, Amphetamines, Methamphetamines, and Opiates) could be compared to that of the standard hospital laboratory analysis of each urine specimen (which also included Barbiturates and Benzodiazepines). In the six-month period of this study, nearly two-thirds of trauma center admissions were victims of motor vehicle crashes. During this time, blood and urine was collected from 322 MVC victims. Toxicology results indicated that 59.3% of MVC victims tested positive for either commonly abused drugs or alcohol. More patients tested positive for drug use than tested positive for alcohol, with 33.5% testing positive for drug use only, 15.8% testing positive for alcohol use only, and 9.9% testing positive for both drugs and alcohol. Less than half (45.2%) of the substance-abusing patients in this study would have been identified by an alcohol test alone. After alcohol, marijuana and benzodiazepines were the most frequently detected drugs. Point of collection (POC) test results correlated well with laboratory results and provide important information to initiate rapid intervention/treatment for substance use problems among injured patients.

  17. Comparing reliabilities of strip and conventional patch testing.

    PubMed

    Dickel, Heinrich; Geier, Johannes; Kreft, Burkhard; Pfützner, Wolfgang; Kuss, Oliver

    2017-06-01

    The standardized protocol for performing the strip patch test has proven to be valid, but evidence on its reliability is still missing. To estimate the parallel-test reliability of the strip patch test as compared with the conventional patch test. In this multicentre, prospective, randomized, investigator-blinded reliability study, 132 subjects were enrolled. Simultaneous duplicate strip and conventional patch tests were performed with the Finn Chambers ® on Scanpor ® tape test system and the patch test preparations nickel sulfate 5% pet., potassium dichromate 0.5% pet., and lanolin alcohol 30% pet. Reliability was estimated by the use of Cohen's kappa coefficient. Parallel-test reliability values of the three standard patch test preparations turned out to be acceptable, with slight advantages for the strip patch test. The differences in reliability were 9% (95%CI: -8% to 26%) for nickel sulfate and 23% (95%CI: -16% to 63%) for potassium dichromate, both favouring the strip patch test. The standardized strip patch test method for the detection of allergic contact sensitization in patients with suspected allergic contact dermatitis is reliable. Its application in routine clinical practice can be recommended, especially if the conventional patch test result is presumably false negative. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Standards Development Activities at White Sands Test Facility

    NASA Technical Reports Server (NTRS)

    Baker, D. L.; Beeson, H. D.; Saulsberry, R. L.; Julien, H. L.; Woods, S. S.

    2003-01-01

    The development of standards and standard activities at the JSC White Sands Test Facility (WSTF) has been expanded to include the transfer of technology and standards to voluntary consensus organizations in five technical areas of importance to NASA. This effort is in direct response to the National Technology Transfer Act designed to accelerate transfer of technology to industry and promote government-industry partnerships. Technology transfer is especially important for WSTF, whose longterm mission has been to develop and provide vital propellant safety and hazards information to aerospace designers, operations personnel, and safety personnel. Meeting this mission is being accomplished through the preparation of consensus guidelines and standards, propellant hazards analysis protocols, and safety courses for the propellant use of hydrogen, oxygen, and hypergols, as well as the design and inspection of spacecraft pressure vessels and the use of pyrovalves in spacecraft propulsion systems. The overall WSTF technology transfer program is described and the current status of technology transfer activities are summarized.

  19. Applying an Empirical Hydropathic Forcefield in Refinement May Improve Low-Resolution Protein X-Ray Crystal Structures

    PubMed Central

    Koparde, Vishal N.; Scarsdale, J. Neel; Kellogg, Glen E.

    2011-01-01

    Background The quality of X-ray crystallographic models for biomacromolecules refined from data obtained at high-resolution is assured by the data itself. However, at low-resolution, >3.0 Å, additional information is supplied by a forcefield coupled with an associated refinement protocol. These resulting structures are often of lower quality and thus unsuitable for downstream activities like structure-based drug discovery. Methodology An X-ray crystallography refinement protocol that enhances standard methodology by incorporating energy terms from the HINT (Hydropathic INTeractions) empirical forcefield is described. This protocol was tested by refining synthetic low-resolution structural data derived from 25 diverse high-resolution structures, and referencing the resulting models to these structures. The models were also evaluated with global structural quality metrics, e.g., Ramachandran score and MolProbity clashscore. Three additional structures, for which only low-resolution data are available, were also re-refined with this methodology. Results The enhanced refinement protocol is most beneficial for reflection data at resolutions of 3.0 Å or worse. At the low-resolution limit, ≥4.0 Å, the new protocol generated models with Cα positions that have RMSDs that are 0.18 Å more similar to the reference high-resolution structure, Ramachandran scores improved by 13%, and clashscores improved by 51%, all in comparison to models generated with the standard refinement protocol. The hydropathic forcefield terms are at least as effective as Coulombic electrostatic terms in maintaining polar interaction networks, and significantly more effective in maintaining hydrophobic networks, as synthetic resolution is decremented. Even at resolutions ≥4.0 Å, these latter networks are generally native-like, as measured with a hydropathic interactions scoring tool. PMID:21246043

  20. Rapid Diagnosis of Tuberculosis by Real-Time High-Resolution Imaging of Mycobacterium tuberculosis Colonies.

    PubMed

    Ghodbane, Ramzi; Asmar, Shady; Betzner, Marlena; Linet, Marie; Pierquin, Joseph; Raoult, Didier; Drancourt, Michel

    2015-08-01

    Culture remains the cornerstone of diagnosis for pulmonary tuberculosis, but the fastidiousness of Mycobacterium tuberculosis may delay culture-based diagnosis for weeks. We evaluated the performance of real-time high-resolution imaging for the rapid detection of M. tuberculosis colonies growing on a solid medium. A total of 50 clinical specimens, including 42 sputum specimens, 4 stool specimens, 2 bronchoalveolar lavage fluid specimens, and 2 bronchial aspirate fluid specimens were prospectively inoculated into (i) a commercially available Middlebrook broth and evaluated for mycobacterial growth indirectly detected by measuring oxygen consumption (standard protocol) and (ii) a home-made solid medium incubated in an incubator featuring real-time high-resolution imaging of colonies (real-time protocol). Isolates were identified by Ziehl-Neelsen staining and matrix-assisted laser desorption ionization-time of flight mass spectrometry. Use of the standard protocol yielded 14/50 (28%) M. tuberculosis isolates, which is not significantly different from the 13/50 (26%) M. tuberculosis isolates found using the real-time protocol (P = 1.00 by Fisher's exact test), and the contamination rate of 1/50 (2%) was not significantly different from the contamination rate of 2/50 (4%) using the real-time protocol (P = 1.00). The real-time imaging protocol showed a 4.4-fold reduction in time to detection, 82 ± 54 h versus 360 ± 142 h (P < 0.05). These preliminary data give the proof of concept that real-time high-resolution imaging of M. tuberculosis colonies is a new technology that shortens the time to growth detection and the laboratory diagnosis of pulmonary tuberculosis. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  1. Reproducibility analysis of upper limbs reachable workspace, and effects of acquisition protocol, sex and hand dominancy.

    PubMed

    Clément, Julien; Raison, Maxime; Rouleau, Dominique M

    2018-02-08

    None of the physical testing, nor the goniometers currently used to assess upper limb function have a high validity, sensitivity or reliability. The reachable workspace, i.e. the area covered by the farthest points a subject can reach by hand without moving his/her body, shows promise but has yet to be validated, particularly in terms of reproducibility. Therefore, this study aims to evaluate the reproducibility of the reachable workspace over a period of several weeks, and to assess the effects of two proposed acquisition protocols, as well as those of gender, and hand dominancy. Shoulder movements were recorded using a motion capture system on 10 female and 10 male healthy subjects during a random protocol, i.e. simply asking them to achieve the farthest points they could reach with their hands, and during a standardized protocol, i.e. asking them to perform predefined shoulder elevations while keeping their trunk and elbow straight. The standardized protocol was repeated 7 weeks later. Repeated measures showed no significant difference, good to excellent intraclass correlation coefficients (0.46-0.81) and small bias (0.0-1.2%). The random protocol provided significantly lower and more scattered values for the reachable workspace (80.0 ± 22.6% vs. 91.0 ± 8.1%, p = .004), whereas gender and hand-dominancy had no effect. This study showed that the reachable workspace was highly reliable over a period of 7 weeks and that both upper limbs provided similar results. It could be used to monitor various pathologies of the upper limbs and to assess treatment efficiency, using a subject's healthy limb as reference. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Optimization of Saanen sperm genes amplification: evaluation of standardized protocols in genetically uncharacterized rural goats reared under a subtropical environment.

    PubMed

    Barbour, Elie K; Saade, Maya F; Sleiman, Fawwak T; Hamadeh, Shady K; Mouneimne, Youssef; Kassaifi, Zeina; Kayali, Ghazi; Harakeh, Steve; Jaber, Lina S; Shaib, Houssam A

    2012-10-01

    The purpose of this research is to optimize quantitatively the amplification of specific sperm genes in reference genomically characterized Saanen goat and to evaluate the standardized protocols applicability on sperms of uncharacterized genome of rural goats reared under subtropical environment for inclusion in future selection programs. The optimization of the protocols in Saanen sperms included three production genes (growth hormone (GH) exons 2, 3, and 4, αS1-casein (CSN1S1), and α-lactalbumin) and two health genes (MHC class II DRB and prion (PrP)). The optimization was based on varying the primers concentrations and the inclusion of a PCR cosolvent (Triton X). The impact of the studied variables on statistically significant increase in the yield of amplicons was noticed in four out of five (80%) optimized protocols, namely in those related to GH, CSN1S1, α-lactalbumin, and PrP genes (P < 0.05). There was no significant difference in the yield of amplicons related to MHC class II DRB gene, regardless of the variables used (P > 0.05). The applicability of the optimized protocols of Saanen sperm genes on amplification of uncharacterized rural goat sperms revealed a 100% success in tested individuals for amplification of GH, CSN1S1, α-lactalbumin, and MHC class II DRB genes and a 75% success for the PrP gene. The significant success in applicability of the Saanen quantitatively optimized protocols to other uncharacterized genome of rural goats allows for their inclusion in future selection, targeting the sustainability of this farming system in a subtropical environment and the improvement of the farmers livelihood.

  3. Quality assessment program for EuroFlow protocols: summary results of four-year (2010-2013) quality assurance rounds.

    PubMed

    Kalina, Tomas; Flores-Montero, Juan; Lecrevisse, Quentin; Pedreira, Carlos E; van der Velden, Vincent H J; Novakova, Michaela; Mejstrikova, Ester; Hrusak, Ondrej; Böttcher, Sebastian; Karsch, Dennis; Sędek, Łukasz; Trinquand, Amelie; Boeckx, Nancy; Caetano, Joana; Asnafi, Vahid; Lucio, Paulo; Lima, Margarida; Helena Santos, Ana; Bonaccorso, Paola; van der Sluijs-Gelling, Alita J; Langerak, Anton W; Martin-Ayuso, Marta; Szczepański, Tomasz; van Dongen, Jacques J M; Orfao, Alberto

    2015-02-01

    Flow cytometric immunophenotyping has become essential for accurate diagnosis, classification, and disease monitoring in hemato-oncology. The EuroFlow Consortium has established a fully standardized "all-in-one" pipeline consisting of standardized instrument settings, reagent panels, and sample preparation protocols and software for data analysis and disease classification. For its reproducible implementation, parallel development of a quality assurance (QA) program was required. Here, we report on the results of four consecutive annual rounds of the novel external QA EuroFlow program. The novel QA scheme aimed at monitoring the whole flow cytometric analysis process (cytometer setting, sample preparation, acquisition and analysis) by reading the median fluorescence intensities (MedFI) of defined lymphocytes' subsets. Each QA participant applied the predefined reagents' panel on blood cells of local healthy donors. A uniform gating strategy was applied to define lymphocyte subsets and to read MedFI values per marker. The MedFI values were compared with reference data and deviations from reference values were quantified using performance score metrics. In four annual QA rounds, we analyzed 123 blood samples from local healthy donors on 14 different instruments in 11 laboratories from nine European countries. The immunophenotype of defined cellular subsets appeared sufficiently standardized to permit unified (software) data analysis. The coefficient of variation of MedFI for 7 of 11 markers performed repeatedly below 30%, average MedFI in each QA round ranged from 86 to 125% from overall median. Calculation of performance scores was instrumental to pinpoint standardization failures and their causes. Overall, the new EuroFlow QA system for the first time allowed to quantify the technical variation that is introduced in the measurement of fluorescence intensities in a multicentric setting over an extended period of time. EuroFlow QA is a proficiency test specific for laboratories that use standardized EuroFlow protocols. It may be used to complement, but not replace, established proficiency tests. © 2014 International Society for Advancement of Cytometry. © 2014 International Society for Advancement of Cytometry.

  4. Who needs inpatient detox? Development and implementation of a hospitalist protocol for the evaluation of patients for alcohol detoxification.

    PubMed

    Stephens, John R; Liles, E Allen; Dancel, Ria; Gilchrist, Michael; Kirsch, Jonathan; DeWalt, Darren A

    2014-04-01

    Clinicians caring for patients seeking alcohol detoxification face many challenges, including lack of evidence-based guidelines for treatment and high recidivism rates. To develop a standardized protocol for determining which alcohol dependent patients seeking detoxification need inpatient versus outpatient treatment, and to study the protocol's implementation. Review of best evidence by ad hoc task force and subsequent creation of standardized protocol. Prospective observational evaluation of initial protocol implementation. Patients presenting for alcohol detoxification. Development and implementation of a protocol for evaluation and treatment of patients requesting alcohol detoxification. Number of admissions per month with primary alcohol related diagnosis (DRG), 30-day readmission rate, and length of stay, all measured before and after protocol implementation. We identified one randomized clinical trial and three cohort studies to inform the choice of inpatient versus outpatient detoxification, along with one prior protocol in this population, and combined that data with clinical experience to create an institutional protocol. After implementation, the average number of alcohol related admissions was 15.9 per month, compared with 18.9 per month before implementation (p = 0.037). There was no difference in readmission rate or length of stay. Creation and utilization of a protocol led to standardization of care for patients requesting detoxification from alcohol. Initial evaluation of protocol implementation showed a decrease in number of admissions.

  5. NIH Mouse Metabolic Phenotyping Centers: the power of centralized phenotyping.

    PubMed

    Laughlin, Maren R; Lloyd, K C Kent; Cline, Gary W; Wasserman, David H

    2012-10-01

    The Mouse Metabolic Phenotyping Centers (MMPCs) were founded in 2001 by the National Institutes of Health (NIH) to advance biomedical research by providing the scientific community with standardized, high-quality phenotyping services for mouse models of diabetes, obesity, and their complications. The intent is to allow researchers to take optimum advantage of the many new mouse models produced in labs and in high-throughput public efforts. The six MMPCs are located at universities around the country and perform complex metabolic tests in intact mice and hormone and analyte assays in tissues on a fee-for-service basis. Testing is subsidized by the NIH in order to reduce the barriers for mouse researchers. Although data derived from these tests belong to the researcher submitting mice or tissues, these data are archived after publication in a public database run by the MMPC Coordinating and Bioinformatics Unit. It is hoped that data from experiments performed in many mouse models of metabolic diseases, using standard protocols, will be useful in understanding the nature of these complex disorders. The current areas of expertise include energy balance and body composition, insulin action and secretion, whole-body and tissue carbohydrate and lipid metabolism, cardiovascular and renal function, and metabolic pathway kinetics. In addition to providing services, the MMPC staff provides expertise and advice to researchers, and works to develop and refine test protocols to best meet the community's needs in light of current scientific developments. Test technology is disseminated by publications and through annual courses.

  6. A Multi-Center Space Data System Prototype Based on CCSDS Standards

    NASA Technical Reports Server (NTRS)

    Rich, Thomas M.

    2016-01-01

    Deep space missions beyond earth orbit will require new methods of data communications in order to compensate for increasing Radio Frequency (RF) propagation delay. The Consultative Committee for Space Data Systems (CCSDS) standard protocols Spacecraft Monitor & Control (SM&C), Asynchronous Message Service (AMS), and Delay/Disruption Tolerant Networking (DTN) provide such a method. However, the maturity level of this protocol stack is insufficient for mission inclusion at this time. This Space Data System prototype is intended to provide experience which will raise the Technical Readiness Level (TRL) of this protocol set. In order to reduce costs, future missions can take advantage of these standard protocols, which will result in increased interoperability between control centers. This prototype demonstrates these capabilities by implementing a realistic space data system in which telemetry is published to control center applications at the Jet Propulsion Lab (JPL), the Marshall Space Flight Center (MSFC), and the Johnson Space Center (JSC). Reverse publishing paths for commanding from each control center are also implemented. The target vehicle consists of realistic flight computer hardware running Core Flight Software (CFS) in the integrated Power, Avionics, and Power (iPAS) Pathfinder Lab at JSC. This prototype demonstrates a potential upgrade path for future Deep Space Network (DSN) modification, in which the automatic error recovery and communication gap compensation capabilities of DTN would be exploited. In addition, SM&C provides architectural flexibility by allowing new service providers and consumers to be added efficiently anywhere in the network using the common interface provided by SM&C's Message Abstraction Layer (MAL). In FY 2015, this space data system was enhanced by adding telerobotic operations capability provided by the Robot API Delegate (RAPID) family of protocols developed at NASA. RAPID is one of several candidates for consideration and inclusion in a new international standard being developed by the CCSDS Telerobotic Operations Working Group. Software gateways for the purpose of interfacing RAPID messages with the existing SM&C based infrastructure were developed. Telerobotic monitor, control, and bridge applications were written in the RAPID framework, which were then tailored to the NAO telerobotic test article hardware, a product of Aldebaran Robotics.

  7. The Relationship between Types of Attention and Auditory Processing Skills: Reconsidering Auditory Processing Disorder Diagnosis

    PubMed Central

    Stavrinos, Georgios; Iliadou, Vassiliki-Maria; Edwards, Lindsey; Sirimanna, Tony; Bamiou, Doris-Eva

    2018-01-01

    Measures of attention have been found to correlate with specific auditory processing tests in samples of children suspected of Auditory Processing Disorder (APD), but these relationships have not been adequately investigated. Despite evidence linking auditory attention and deficits/symptoms of APD, measures of attention are not routinely used in APD diagnostic protocols. The aim of the study was to examine the relationship between auditory and visual attention tests and auditory processing tests in children with APD and to assess whether a proposed diagnostic protocol for APD, including measures of attention, could provide useful information for APD management. A pilot study including 27 children, aged 7–11 years, referred for APD assessment was conducted. The validated test of everyday attention for children, with visual and auditory attention tasks, the listening in spatialized noise sentences test, the children's communication checklist questionnaire and tests from a standard APD diagnostic test battery were administered. Pearson's partial correlation analysis examining the relationship between these tests and Cochrane's Q test analysis comparing proportions of diagnosis under each proposed battery were conducted. Divided auditory and divided auditory-visual attention strongly correlated with the dichotic digits test, r = 0.68, p < 0.05, and r = 0.76, p = 0.01, respectively, in a sample of 20 children with APD diagnosis. The standard APD battery identified a larger proportion of participants as having APD, than an attention battery identified as having Attention Deficits (ADs). The proposed APD battery excluding AD cases did not have a significantly different diagnosis proportion than the standard APD battery. Finally, the newly proposed diagnostic battery, identifying an inattentive subtype of APD, identified five children who would have otherwise been considered not having ADs. The findings show that a subgroup of children with APD demonstrates underlying sustained and divided attention deficits. Attention deficits in children with APD appear to be centred around the auditory modality but further examination of types of attention in both modalities is required. Revising diagnostic criteria to incorporate attention tests and the inattentive type of APD in the test battery, provides additional useful data to clinicians to ensure careful interpretation of APD assessments. PMID:29441033

  8. Lack of evidence of a beneficial effect of azathioprine in dogs treated with prednisolone for idiopathic immune-mediated hemolytic anemia: a retrospective cohort study.

    PubMed

    Piek, Christine J; van Spil, Willem Evert; Junius, Greet; Dekker, Aldo

    2011-04-13

    Azathioprine is used as an immunosuppressant in canine immune-mediated hemolytic anemia (IMHA), but this potentially toxic and carcinogenic drug has not been proven to be beneficial. The aim of this study was to determine the difference in outcome and survival of dogs with idiopathic IMHA treated with a protocol that included azathioprine and prednisolone versus a protocol that included prednisolone alone. The study included 222 dogs with a hematocrit lower than 0.30 L/L and either a positive Coombs' test or spherocytosis and no evidence of diseases that could trigger IMHA. The clinical and laboratory data at the time of diagnosis and the response to therapy and survival were compared in dogs treated according to the prednisolone and azathioprine protocol (AP protocol; n = 149) and dogs treated according to the prednisolone protocol (P protocol; n = 73). At study entry, the two groups were comparable, except that thrombocyte counts were significantly lower and clinical signs had been present significantly longer in the AP protocol group. No significant difference in survival was found between the two groups: the 1-year survival was 64% (95% CI 54 - 77%) in the P protocol group and 69% (95% CI 59-80%) in the AP protocol group, respectively. Azathioprine would appear not to be beneficial as standard treatment for all cases of IMHA; however, a blinded, randomized clinical trial is needed to establish whether outcome is different with the two treatment protocols.

  9. Providing predictive testing for Huntington disease via telehealth: results of a pilot study in British Columbia, Canada.

    PubMed

    Hawkins, A K; Creighton, S; Ho, A; McManus, B; Hayden, M R

    2013-07-01

    Predictive testing (PT) for Huntington disease (HD) usually requires several in-person appointments which acts as a barrier to testing for those from remote regions. This pilot study reports the use of telehealth PT to examine whether such telehealth testing improves access to HD PT while maintaining quality of care and support. Individuals underwent PT via the telehealth protocol or standard in-person protocol and were asked to complete surveys regarding their experience. Results reveal no significant differences between the in-person-tested and telehealth-tested groups with respect to quality of care, information, counselling and support. The majority of participants in both groups stated that pre-test counselling had provided them with sufficient knowledge about the advantages and disadvantages of undergoing testing, the opportunity to ask questions, and the ability to make an informed decision. The majority of participants in both groups were satisfied by the manner in which results were delivered and stated they had received sufficient information regarding the implications of these results. This study reveals that telehealth PT improves access while maintaining quality of care and support. © 2012 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. Phase Transition in Protocols Minimizing Work Fluctuations

    NASA Astrophysics Data System (ADS)

    Solon, Alexandre P.; Horowitz, Jordan M.

    2018-05-01

    For two canonical examples of driven mesoscopic systems—a harmonically trapped Brownian particle and a quantum dot—we numerically determine the finite-time protocols that optimize the compromise between the standard deviation and the mean of the dissipated work. In the case of the oscillator, we observe a collection of protocols that smoothly trade off between average work and its fluctuations. However, for the quantum dot, we find that as we shift the weight of our optimization objective from average work to work standard deviation, there is an analog of a first-order phase transition in protocol space: two distinct protocols exchange global optimality with mixed protocols akin to phase coexistence. As a result, the two types of protocols possess qualitatively different properties and remain distinct even in the infinite duration limit: optimal-work-fluctuation protocols never coalesce with the minimal-work protocols, which therefore never become quasistatic.

  11. ASRM standard embryo transfer protocol template: a committee opinion.

    PubMed

    Penzias, Alan; Bendikson, Kristin; Butts, Samantha; Coutifaris, Christos; Falcone, Tommaso; Fossum, Gregory; Gitlin, Susan; Gracia, Clarisa; Hansen, Karl; Mersereau, Jennifer; Odem, Randall; Rebar, Robert; Reindollar, Richard; Rosen, Mitchell; Sandlow, Jay; Vernon, Michael

    2017-04-01

    Standardization improves performance and safety. A template for standardizing the embryo transfer procedure is presented here with 12 basic steps supported by published scientific literature and a survey of common practice of SART programs; it can be used by ART practices to model their own standard protocol. Copyright © 2017 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  12. Immunosuppression for in vivo research: state-of-the-art protocols and experimental approaches

    PubMed Central

    Diehl, Rita; Ferrara, Fabienne; Müller, Claudia; Dreyer, Antje Y; McLeod, Damian D; Fricke, Stephan; Boltze, Johannes

    2017-01-01

    Almost every experimental treatment strategy using non-autologous cell, tissue or organ transplantation is tested in small and large animal models before clinical translation. Because these strategies require immunosuppression in most cases, immunosuppressive protocols are a key element in transplantation experiments. However, standard immunosuppressive protocols are often applied without detailed knowledge regarding their efficacy within the particular experimental setting and in the chosen model species. Optimization of such protocols is pertinent to the translation of experimental results to human patients and thus warrants further investigation. This review summarizes current knowledge regarding immunosuppressive drug classes as well as their dosages and application regimens with consideration of species-specific drug metabolization and side effects. It also summarizes contemporary knowledge of novel immunomodulatory strategies, such as the use of mesenchymal stem cells or antibodies. Thus, this review is intended to serve as a state-of-the-art compendium for researchers to refine applied experimental immunosuppression and immunomodulation strategies to enhance the predictive value of preclinical transplantation studies. PMID:27721455

  13. The Impact of Injector-Based Contrast Agent Administration on Bolus Shape and Magnetic Resonance Angiography Image Quality.

    PubMed

    Jost, Gregor; Endrikat, Jan; Pietsch, Hubertus

    2017-01-01

    To compare injector-based contrast agent (CA) administration with hand injection in magnetic resonance angiography (MRA). Gadobutrol was administered in 6 minipigs with 3 protocols: (a) hand injection (one senior technician), (b) hand injection (6 less-experienced technicians), and (c) power injector administration. The arterial bolus shape was quantified by test bolus measurements. A head and neck MRA was performed for quantitative and qualitative comparison of signal enhancement. A significantly shorter time to peak was observed for protocol C, whereas no significant differences between protocols were found for peak height and bolus width. However, for protocol C, these parameters showed a much lower variation. The MRA revealed a significantly higher signal-to-noise ratio for injector-based administration. A superimposed strong contrast of the jugular vein was found in 50% of the hand injections. Injector-based CA administration results in a more standardized bolus shape, a higher vascular contrast, and a more robust visualization of target vessels.

  14. ACR/NEMA Digital Image Interface Standard (An Illustrated Protocol Overview)

    NASA Astrophysics Data System (ADS)

    Lawrence, G. Robert

    1985-09-01

    The American College of Radiologists (ACR) and the National Electrical Manufacturers Association (NEMA) have sponsored a joint standards committee mandated to develop a universal interface standard for the transfer of radiology images among a variety of PACS imaging devicesl. The resulting standard interface conforms to the ISO/OSI standard reference model for network protocol layering. The standard interface specifies the lower layers of the reference model (Physical, Data Link, Transport and Session) and implies a requirement of the Network Layer should a requirement for a network exist. The message content has been considered and a flexible message and image format specified. The following Imaging Equipment modalities are supported by the standard interface... CT Computed Tomograpy DS Digital Subtraction NM Nuclear Medicine US Ultrasound MR Magnetic Resonance DR Digital Radiology The following data types are standardized over the transmission interface media.... IMAGE DATA DIGITIZED VOICE HEADER DATA RAW DATA TEXT REPORTS GRAPHICS OTHERS This paper consists of text supporting the illustrated protocol data flow. Each layer will be individually treated. Particular emphasis will be given to the Data Link layer (Frames) and the Transport layer (Packets). The discussion utilizes a finite state sequential machine model for the protocol layers.

  15. Workshop on standards in biomass for energy and chemicals: proceedings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Milne, T.A.

    1984-11-01

    In the course of reviewing standards literature, visiting prominent laboratories and research groups, attending biomass meetings and corresponding widely, a whole set of standards needs was identified, the most prominent of which were: biomass standard reference materials, research materials and sample banks; special collections of microorganisms, clonal material, algae, etc.; standard methods of characterization of substrates and biomass fuels; standard tests and methods for the conversion and end-use of biomass; standard protocols for the description, harvesting, preparation, storage, and measurement of productivity of biomass materials in the energy context; glossaries of terms; development of special tests for assay of enzymaticmore » activity and related processes. There was also a recognition of the need for government, professional and industry support of concensus standards development and the dissemination of information on standards. Some 45 biomass researchers and managers met with key NBS staff to identify and prioritize standards needs. This was done through three working panels: the Panel on Standard Reference Materials (SRM's), Research Materials (RM's), and Sample Banks; the Panel on Production and Characterization; and the Panel on Tests and Methods for Conversion and End Use. This report gives a summary of the action items in standards development recommended unanimously by the workshop attendees. The proceedings of the workshop, and an appendix, contain an extensive written record of the findings of the workshop panelists and others regarding presently existing standards and standards issues and needs. Separate abstracts have been prepared for selected papers for inclusion in the Energy Database.« less

  16. Assessing and Reporting Dancer Capacities, Risk Factors, and Injuries: Recommendations from the IADMS Standard Measures Consensus Initiative.

    PubMed

    Liederbach, Marijeanne; Hagins, Marshall; Gamboa, Jennifer M; Welsh, Thomas M

    2012-12-01

    This technical report of the Standard Measures Consensus Initiative of the International Association for Dance Medicine and Science (IADMS) describes the results of the committee’s multi-year effort to synthesize information regarding the tests and measures used in dance-related research, protocols for reporting injuries, and appropriate use of available technologies to aid in standardizing such matters. Specific recommendations are presented, with accompanying rationales, to facilitate consensus among members of the dance medicine and science community. An Executive Summary of this Technical Report, which contains implementation strategies and appendices, should soon be available on the IADMS website.

  17. Nasal potential difference measurements in diagnosis of cystic fibrosis: an international survey.

    PubMed

    Naehrlich, Lutz; Ballmann, Manfred; Davies, Jane; Derichs, Nico; Gonska, Tanja; Hjelte, Lena; van Konigsbruggen-Rietschel, Silke; Leal, Teresinha; Melotti, Paola; Middleton, Peter; Tümmler, Burkhard; Vermeulen, Francois; Wilschanski, Michael

    2014-01-01

    The role of nasal potential difference (NPD) measurement as a diagnostic test for cystic fibrosis (CF) is a subject of global controversy because of the lack of validation studies, clear reference values, and standardized protocols for diagnostic NPD. To determine diagnostic NPD frequency, protocols, interpretation, and rater agreement, we surveyed the 18 NPD centres of the European Cystic Fibrosis Society Diagnostic Network Working Group. Fifteen centres reported performing 373 diagnostic NPDs in 2012. Most use the CFF-TDN-SOP (67%) and the chloride-free + isoproterenol response of the side with the largest response (47%) as diagnostic criteria and use centre-specific reference ranges. Rater agreement for five NPD tracings - in general - was good, but poor in tracings with different responses between the two nostrils. NPD is frequently used as a diagnostic and research tool for CF. Performance is highly standardized, centre-specific reference ranges are established, and rater agreement - in general - is good. Centre-independent diagnostic criteria and reference ranges must be defined by multicentre validation studies to improve standardized interpretation for diagnostic use. © 2013.

  18. Development of a frequency regulation duty-cycle for standardized energy storage performance testing

    DOE PAGES

    Rosewater, David; Ferreira, Summer

    2016-05-25

    The US DOE Protocol for uniformly measuring and expressing the performance of energy storage systems, first developed in 2012 through inclusive working group activities, provides standardized methodologies for evaluating an energy storage system’s ability to supply specific services to electrical grids. This article elaborates on the data and decisions behind the duty-cycle used for frequency regulation in this protocol. Analysis of a year of publicly available frequency regulation control signal data from a utility was considered in developing the representative signal for this use case. Moreover, this showed that signal standard deviation can be used as a metric for aggressivenessmore » or rigor. From these data, we select representative 2 h long signals that exhibit nearly all of dynamics of actual usage under two distinct regimens, one for average use and the other for highly aggressive use. Our results were combined into a 24-h duty-cycle comprised of average and aggressive segments. The benefits and drawbacks of the selected duty-cycle are discussed along with its potential implications to the energy storage industry.« less

  19. Validation of the Grandway MD2301 digital automatic blood pressure monitor according to the European Society of Hypertension International Protocol.

    PubMed

    Chen, Wan; Zeng, Zhao-Lin; Bing, Sen; Li, Lin-Yi; Wang, Rui; Wan, Yi

    2016-08-01

    The aim of the present study was to validate the Grandway MD2301 digital automatic blood pressure monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010. The ESH-IP revision 2010 for the validation of blood pressure-measuring devices in adults was followed precisely. Systolic and diastolic blood pressure (SBP and DBP, respectively) were measured sequentially in 33 adult patients and compared with a standard mercury sphygmomanometer (two observers). A total of 99 comparison pairs were obtained. The device produced 78, 95 and 99 measurements within 5, 10, and 15 mmHg for SBP and 83, 96, and 99 for DBP, respectively. The average device-observer difference was -1.81±4.22 mmHg for SBP and -0.15±3.93 mmHg for DBP. All of the data were within the standards requirements to pass the testing. The Grandway MD2301 digital automatic blood pressure monitor meets the standards of the ESH-IP revision 2010 and can be recommended for self/home measurement in the general population.

  20. An XML-Based Protocol for Distributed Event Services

    NASA Technical Reports Server (NTRS)

    Smith, Warren; Gunter, Dan; Quesnel, Darcy; Biegel, Bryan (Technical Monitor)

    2001-01-01

    A recent trend in distributed computing is the construction of high-performance distributed systems called computational grids. One difficulty we have encountered is that there is no standard format for the representation of performance information and no standard protocol for transmitting this information. This limits the types of performance analysis that can be undertaken in complex distributed systems. To address this problem, we present an XML-based protocol for transmitting performance events in distributed systems and evaluate the performance of this protocol.

  1. An investigation into the nutritional status of patients receiving an Enhanced Recovery After Surgery (ERAS) protocol versus standard care following Oesophagectomy.

    PubMed

    Benton, Katie; Thomson, Iain; Isenring, Elisabeth; Mark Smithers, B; Agarwal, Ekta

    2018-06-01

    Enhanced Recovery After Surgery (ERAS) protocols have been effectively expanded to various surgical specialities including oesophagectomy. Despite nutrition being a key component, actual nutrition outcomes and specific guidelines are lacking. This cohort comparison study aims to compare nutritional status and adherence during implementation of a standardised post-operative nutritional support protocol, as part of ERAS, compared to those who received usual care. Two groups of patients undergoing resection of oesophageal cancer were studied. Group 1 (n = 17) underwent oesophagectomy between Oct 2014 and Nov 2016 during implementation of an ERAS protocol. Patients in group 2 (n = 16) underwent oesophagectomy between Jan 2011 and Dec 2012 prior to the implementation of ERAS. Demographic, nutritional status, dietary intake and adherence data were collected. Ordinal data was analysed using independent t tests, and categorical data using chi-square tests. There was no significant difference in nutrition status, dietary intake or length of stay following implementation of an ERAS protocol. Malnutrition remained prevalent in both groups at day 42 post surgery (n = 10, 83% usual care; and n = 9, 60% ERAS). A significant difference was demonstrated in adherence with earlier initiation of oral free fluids (p <0.008), transition to soft diet (p <0.004) and continuation of jejunostomy feeds on discharge (p <0.000) for the ERAS group. A standardised post-operative nutrition protocol, within an ERAS framework, results in earlier transition to oral intake; however, malnutrition remains prevalent post surgery. Further large-scale studies are warranted to examine individualised decision-making regarding nutrition support within an ERAS protocol.

  2. The Acute Effects of Static Stretching Compared to Dynamic Stretching with and without an Active Warm up on Anaerobic Performance

    PubMed Central

    KENDALL, BRADLEY J.

    2017-01-01

    The Wingate Anaerobic Test (WAnT) has been used in many studies to determine anaerobic performance. However, there has been poor reporting of warm-up protocols and limited consistency between warm-up methods that have been used. With the WAnT being such a commonly-used test, consistency in warm-up methods is essential in order to compare results across studies. Therefore, this study was designed to compare how static stretching, dynamic stretching, and an active warm-up affect WAnT performance. Ten recreationally active participants (5 males, 5 females) with a mean (SD) age of 23.3 (0.7) volunteered for this study. Subjects were randomized to a specific order of five warm-up protocols, which were performed on individual days followed by a WAnT. Peak power, mean power, power drop, and fatigue index were compared for each trial using a repeated measures ANOVA. For peak power, results revealed that warm-up protocol had a significant effect, F(4,36) = 3.90, p = .01, partial η2 = .302. It was hypothesized that the dynamic stretching would lead to greater peak power than the static stretching protocol. However, results of post hoc analyses failed to detect a significant difference (p =.065). For the other measured variables no significant differences were found. The findings from this study suggest that warm-up protocols may have significantly different impacts on peak power during the WAnT. Additional research should use larger sample sizes and further explore these warm-up protocols. Developing a standardized warm-up protocol for the WAnT may improve consistency between studies. PMID:28479947

  3. The Acute Effects of Static Stretching Compared to Dynamic Stretching with and without an Active Warm up on Anaerobic Performance.

    PubMed

    Kendall, Bradley J

    2017-01-01

    The Wingate Anaerobic Test (WAnT) has been used in many studies to determine anaerobic performance. However, there has been poor reporting of warm-up protocols and limited consistency between warm-up methods that have been used. With the WAnT being such a commonly-used test, consistency in warm-up methods is essential in order to compare results across studies. Therefore, this study was designed to compare how static stretching, dynamic stretching, and an active warm-up affect WAnT performance. Ten recreationally active participants (5 males, 5 females) with a mean (SD) age of 23.3 (0.7) volunteered for this study. Subjects were randomized to a specific order of five warm-up protocols, which were performed on individual days followed by a WAnT. Peak power, mean power, power drop, and fatigue index were compared for each trial using a repeated measures ANOVA. For peak power, results revealed that warm-up protocol had a significant effect, F (4,36) = 3.90, p = .01, partial η 2 = .302. It was hypothesized that the dynamic stretching would lead to greater peak power than the static stretching protocol. However, results of post hoc analyses failed to detect a significant difference (p =.065). For the other measured variables no significant differences were found. The findings from this study suggest that warm-up protocols may have significantly different impacts on peak power during the WAnT. Additional research should use larger sample sizes and further explore these warm-up protocols. Developing a standardized warm-up protocol for the WAnT may improve consistency between studies.

  4. Ultralow dose dentomaxillofacial CT imaging and iterative reconstruction techniques: variability of Hounsfield units and contrast-to-noise ratio

    PubMed Central

    Bischel, Alexander; Stratis, Andreas; Kakar, Apoorv; Bosmans, Hilde; Jacobs, Reinhilde; Gassner, Eva-Maria; Puelacher, Wolfgang; Pauwels, Ruben

    2016-01-01

    Objective: The aim of this study was to evaluate whether application of ultralow dose protocols and iterative reconstruction technology (IRT) influence quantitative Hounsfield units (HUs) and contrast-to-noise ratio (CNR) in dentomaxillofacial CT imaging. Methods: A phantom with inserts of five types of materials was scanned using protocols for (a) a clinical reference for navigated surgery (CT dose index volume 36.58 mGy), (b) low-dose sinus imaging (18.28 mGy) and (c) four ultralow dose imaging (4.14, 2.63, 0.99 and 0.53 mGy). All images were reconstructed using: (i) filtered back projection (FBP); (ii) IRT: adaptive statistical iterative reconstruction-50 (ASIR-50), ASIR-100 and model-based iterative reconstruction (MBIR); and (iii) standard (std) and bone kernel. Mean HU, CNR and average HU error after recalibration were determined. Each combination of protocols was compared using Friedman analysis of variance, followed by Dunn's multiple comparison test. Results: Pearson's sample correlation coefficients were all >0.99. Ultralow dose protocols using FBP showed errors of up to 273 HU. Std kernels had less HU variability than bone kernels. MBIR reduced the error value for the lowest dose protocol to 138 HU and retained the highest relative CNR. ASIR could not demonstrate significant advantages over FBP. Conclusions: Considering a potential dose reduction as low as 1.5% of a std protocol, ultralow dose protocols and IRT should be further tested for clinical dentomaxillofacial CT imaging. Advances in knowledge: HU as a surrogate for bone density may vary significantly in CT ultralow dose imaging. However, use of std kernels and MBIR technology reduce HU error values and may retain the highest CNR. PMID:26859336

  5. Improving preterm infant outcomes: implementing an evidence-based oral feeding advancement protocol in the neonatal intensive care unit.

    PubMed

    Kish, Mary Z

    2014-10-01

    The ability of a preterm infant to exclusively oral feed is a necessary standard for discharge readiness from the neonatal intensive care unit (NICU). Many of the interventions related to oral feeding advancement currently employed for preterm infants in the NICU are based on individual nursing observations and judgment. Studies involving standardized feeding protocols for oral feeding advancement have been shown to decrease variability in feeding practices, facilitate shortened transition times from gavage to oral feedings, improve bottle feeding performance, and significantly decrease the length of stay (LOS) in the NICU. This project critically evaluated the implementation of an oral feeding advancement protocol in a 74-bed level III NICU in an attempt to standardize the process of advancing oral feedings in medically stable preterm infants. A comprehensive review of the literature identified key features for successful oral feeding in preterm infants. Strong levels of evidence suggested an association between both nonnutritive sucking (NNS) opportunities and standardized feeding advancement protocols with successful oral feeding in preterm infants. These findings prompted a pilot practice change using a feeding advancement protocol and consisted of NNS and standardized oral feeding advancement opportunities. Time to exclusive oral feedings and LOS were compared pre- and postprotocol implementation during more than a 2-month evaluation period. Infants using NNS and the standardized oral feeding advancement protocol had an observed reduction in time to exclusive oral feedings and LOS, although statistical significance was not achieved.

  6. Efficacy of an accelerated recovery protocol for Oxford unicompartmental knee arthroplasty--a randomised controlled trial.

    PubMed

    Reilly, K A; Beard, D J; Barker, K L; Dodd, C A F; Price, A J; Murray, D W

    2005-10-01

    Unicompartmental knee arthroplasty (UKA) is appropriate for one in four patients with osteoarthritic knees. This study was performed to compare the safety, effectiveness and economic viability of a new accelerated protocol with current standard care in a state healthcare system. A single blind RCT design was used. Eligible patients were screened for NSAID tolerance, social circumstances and geographical location before allocation to an accelerated recovery group (A) or standard care group (S). Primary outcome was the Oxford Knee Assessment at 6 months post operation, compared using independent Mann-Whitney U-tests. A simple difference in costs incurred was calculated. The study power was sufficient to avoid type 2 errors. Forty-one patients were included. The average stay for Group A was 1.5 days. Group S averaged 4.3 days. No significant difference in outcomes was found between groups. The new protocol achieved cost savings of 27% and significantly reduced hospital bed occupancy. In addition, patient satisfaction was assessed as greater with the accelerated discharge than with the routine discharge time. The strict inclusion criteria meant that 75% of eligible patients were excluded. However, a large percentage of these were due to the distances patients lived from the hospital.

  7. Muscle recruitment variations during wrist flexion exercise: MR evaluation

    NASA Technical Reports Server (NTRS)

    Fleckenstein, J. L.; Watumull, D.; Bertocci, L. A.; Nurenberg, P.; Peshock, R. M.; Payne, J. A.; Haller, R. G.; Blomqvist, C. G. (Principal Investigator)

    1994-01-01

    OBJECTIVE: Many exercise protocols used in physiological studies assume homogeneous and diffuse muscle recruitment. To test this assumption during a "standard" wrist flexion protocol, variations in muscle recruitment were assessed using MRI in eight healthy subjects. MATERIALS AND METHODS: Variations were assessed by comparing the right to the left forearms and the effect of slight (15 degrees) pronation or supination at the wrist. RESULTS: Postexercise imaging showed focal regions of increased signal intensity (SI), indicating relatively strong recruitment, most often in entire muscles, although occasionally only in subvolumes of muscles. In 15 of 26 studies, flexor carpi radialis (FCR) showed more SI than flexor carpi ulnaris, while in 11 studies SI in these muscles increased equivalently. Relatively greater FCR recruitment was seen during pronation and/or use of the nondominant side. Palmaris longus, a wrist flexor, did not appear recruited in 4 of 11 forearms in which it was present. A portion of the superficial finger flexor became hyperintense in 89% of studies, while recruitment of the deep finger flexor was seen only in 43%. CONCLUSION: Inter- and intraindividual variations in forearm muscle recruitment should be anticipated in physiological studies of standard wrist flexion exercise protocols.

  8. Development of a manualized protocol of massage therapy for clinical trials in osteoarthritis.

    PubMed

    Ali, Ather; Kahn, Janet; Rosenberger, Lisa; Perlman, Adam I

    2012-10-04

    Clinical trial design of manual therapies may be especially challenging as techniques are often individualized and practitioner-dependent. This paper describes our methods in creating a standardized Swedish massage protocol tailored to subjects with osteoarthritis of the knee while respectful of the individualized nature of massage therapy, as well as implementation of this protocol in two randomized clinical trials. The manualization process involved a collaborative process between methodologic and clinical experts, with the explicit goals of creating a reproducible semi-structured protocol for massage therapy, while allowing some latitude for therapists' clinical judgment and maintaining consistency with a prior pilot study. The manualized protocol addressed identical specified body regions with distinct 30- and 60-min protocols, using standard Swedish strokes. Each protocol specifies the time allocated to each body region. The manualized 30- and 60-min protocols were implemented in a dual-site 24-week randomized dose-finding trial in patients with osteoarthritis of the knee, and is currently being implemented in a three-site 52-week efficacy trial of manualized Swedish massage therapy. In the dose-finding study, therapists adhered to the protocols and significant treatment effects were demonstrated. The massage protocol was manualized, using standard techniques, and made flexible for individual practitioner and subject needs. The protocol has been applied in two randomized clinical trials. This manualized Swedish massage protocol has real-world utility and can be readily utilized both in the research and clinical settings. Clinicaltrials.gov NCT00970008 (18 August 2009).

  9. Performance of a Blood Pressure Smartphone App in Pregnant Women: The iPARR Trial (iPhone App Compared With Standard RR Measurement).

    PubMed

    Raichle, Christina J; Eckstein, Jens; Lapaire, Olav; Leonardi, Licia; Brasier, Noé; Vischer, Annina S; Burkard, Thilo

    2018-06-01

    Hypertensive disorders are one of the leading causes of maternal death worldwide. Several smartphone apps claim to measure blood pressure (BP) using photoplethysmographic signals recorded by smartphone cameras. However, no single app has been validated for this use to date. We aimed to validate a new, promising smartphone algorithm. In this subgroup analysis of the iPARR trial (iPhone App Compared With Standard RR Measurement), we tested the Preventicus BP smartphone algorithm on 32 pregnant women. The trial was conducted based on the European Society of Hypertension International Protocol revision 2010 for validation of BP measuring devices in adults. Each individual received 7 sequential BP measurements starting with the reference device (Omron-HBP-1300) and followed by the smartphone measurement, resulting in 96 BP comparisons. Validation requirements of the European Society of Hypertension International Protocol revision 2010 were not fulfilled. Mean (±SD) systolic BP disagreement between the test and reference devices was 5.0 (±14.5) mm Hg. The number of absolute differences between test and reference device within 5, 10, and 15 mm Hg was 31, 53, and 64 of 96, respectively. A Bland-Altman plot showed an overestimation of smartphone-determined systolic BP in comparison with reference systolic BP in low range but an underestimation in medium-range BP. The Preventicus BP smartphone algorithm failed the accuracy criteria for estimating BP in pregnant women and was thus not commercialized. Pregnant women should be discouraged from using BP smartphone apps, unless there are algorithms specifically validated according to common protocols. URL: https://www.clinicaltrials.gov. Unique identifier: NCT02552030. © 2018 American Heart Association, Inc.

  10. Use and qualification of primary and secondary standards employed in quantitative ¹H NMR spectroscopy of pharmaceuticals.

    PubMed

    Rundlöf, Torgny; McEwen, Ian; Johansson, Monika; Arvidsson, Torbjörn

    2014-05-01

    Standards are required in quantitative NMR (qNMR) to obtain accurate and precise results. In this study acetanilide was established and used as a primary standard. Six other chemicals were selected as secondary standards: 3,4,5-trichloropyridine, dimethylterephthalate, maleic acid, 3-sulfolene, 1,4-bis(trimethylsilyl)benzene, and 1,3,5-trimethoxybenzene. The secondary standards were quantified using the primary standard acetanilide. A protocol for qualification and periodic checks of these secondary standards was developed, and used for evaluation of the stability of the compounds. Periodic monitoring of purity was performed for several years. The purity was higher than 99% for all secondary standards. All standards maintained the initial purity during the time period of monitoring, with very small variations in purity (0.3-0.4%). The selected secondary standards were shown to be suitable qNMR standards and that periodic requalification of the standards by qNMR ensures reliable analytical results. These standards have been used in our laboratory for compliance testing of pharmaceutical active substances and approved medicinal products as well as for analysis of suspected illegal medicines. In total more than 1000 samples have been tested using both internal and external standardization and examples are given. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Retrospective analysis supports algorithm as efficient diagnostic approach to treatable intellectual developmental disabilities.

    PubMed

    Sayson, Bryan; Popurs, Marioara Angela Moisa; Lafek, Mirafe; Berkow, Ruth; Stockler-Ipsiroglu, Sylvia; van Karnebeek, Clara D M

    2015-05-01

    Intellectual developmental disorders (IDD(1)), characterized by a significant impairment in cognitive function and behavior, affect 2.5% of the population and are associated with considerable morbidity and healthcare costs. Inborn errors of metabolism (IEM) currently constitute the largest group of genetic defects presenting with IDD, which are amenable to causal therapy. Recently, we created an evidence-based 2-tiered diagnostic protocol (TIDE protocol); the first tier is a 'screening step' applied in all patients, comprising routinely performed, wide available metabolic tests in blood and urine, while second-tier tests are more specific and based on the patient's phenotype. The protocol is supported by an app (www.treatable-ID.org). To retrospectively examine the cost- and time-effectiveness of the TIDE protocol in patients identified with a treatable IEM at the British Columbia Children's Hospital. We searched the database for all IDD patients diagnosed with a treatable IEM, during the period 2000-2009 in our academic institution. Data regarding the patient's clinical phenotype, IEM, diagnostic tests and interval were collected. Total costs and time intervals associated with all testing and physician consultations actually performed were calculated and compared to the model of the TIDE protocol. Thirty-one patients (16 males) were diagnosed with treatable IDD during the period 2000-2009. For those identifiable via the 1st tier (n=20), the average cost savings would have been $311.17 CAD, and for those diagnosed via a second-tier test (n=11) $340.14 CAD. Significant diagnostic delay (mean 9 months; range 1-29 months) could have been avoided in 9 patients with first-tier diagnoses, had the TIDE protocol been used. For those with second-tier treatable IDD, diagnoses could have been more rapidly achieved with the use of the Treatable IDD app allowing for specific searches based on signs and symptoms. The TIDE protocol for treatable forms of IDD appears effective reducing diagnostic delay and unnecessary costs. Larger prospective studies, currently underway, are needed to prove that standard screening for treatable conditions in patients with IDD is time- and cost-effective, and most importantly will preserve brain function by timely diagnosis enabling initiation of causal therapy. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. A model of four hierarchical levels to train Chinese residents' teaching skills for "practice-based learning and improvement" competency.

    PubMed

    Yang, Ying-Ying; Yang, Ling-Yu; Hsu, Hui-Chi; Huang, Chia-Chang; Huang, Chin-Chou; Kirby, Ralph; Cheng, Hao Min; Chang, Ching-Chi; Chuang, Chiao-Lin; Liang, Jen-Feng; Lin, Chun-Chi; Lee, Wei-Shin; Ho, Shung-Tai; Lee, Fa-Yauh

    2015-01-01

    The current study focused on validating a protocol for training and auditing the resident's practice-based learning and improvement (PBLI) and quality improvement (QI) competencies for primary care. Twelve second-year (R2), 12 first-year (R1) and 12 postgraduate year-1 residents were enrolled into group A, B and C, respectively, as trainees. After three training protocols had been completed, a writing test, self-assessed questionnaire and mini-OSTE and end-of-rotation assessment were used in auditing the PBLI competency, performance and teaching ability of trainees. Baseline expert-assessed PBLI and QI knowledge application tool writing scores were low for the R1 and R2 residents. After three training protocols, PBLI and QI proficiencies, performance and teaching abilities were improved to similar levels cross the three training levels of residents based on the expert-assessed writing test-audited assessments and on the faculty and standardized clerk-assessed end-of-rotation-/mini-OSTE-audited assessments. The different four-level hierarchical protocols used to teach group A, B and C were equally beneficial and fitted their needs; namely the different levels of the trainees. Specifically, each level was able to augment their PBLI and QI proficiency. This educational intervention helps medical institutions to train residents as PBLI instructors.

  13. A Standardized Protocol for the Prospective Follow-Up of Cleft Lip and Palate Patients.

    PubMed

    Salimi, Negar; Jolanta, Aleksejūnienė; Edwin, Yen; Angelina, Loo

    2018-01-01

    To develop a standardized all-encompassing protocol for the assessment of cleft lip and palate patients with clinical and research implications. Electronic database searches were conducted and 13 major cleft centers worldwide were contacted in order to prepare for the development of the protocol. In preparation, the available evidence was reviewed and potential fistula-related risk determinants from 4 different domains were identified. No standardized protocol for the assessment of cleft patients could be found in any of the electronic database searches that were conducted. Interviews with representatives from several major centers revealed that the majority of centers do not have a standardized comprehensive strategy for the reporting and follow-up of cleft lip and palate patients. The protocol was developed and consisted of the following domains of determinants: (1) the sociodemographic domain, (2) the cleft defect domain, (3) the surgery domain, and (4) the fistula domain. The proposed protocol has the potential to enhance the quality of patient care by ensuring that multiple patient-related aspects are consistently reported. It may also facilitate future multicenter research, which could contribute to the reduction of fistula occurrence in cleft lip and palate patients.

  14. A bottom-up approach in estimating the measurement uncertainty and other important considerations for quantitative analyses in drug testing for horses.

    PubMed

    Leung, Gary N W; Ho, Emmie N M; Kwok, W Him; Leung, David K K; Tang, Francis P W; Wan, Terence S M; Wong, April S Y; Wong, Colton H F; Wong, Jenny K Y; Yu, Nola H

    2007-09-07

    Quantitative determination, particularly for threshold substances in biological samples, is much more demanding than qualitative identification. A proper assessment of any quantitative determination is the measurement uncertainty (MU) associated with the determined value. The International Standard ISO/IEC 17025, "General requirements for the competence of testing and calibration laboratories", has more prescriptive requirements on the MU than its superseded document, ISO/IEC Guide 25. Under the 2005 or 1999 versions of the new standard, an estimation of the MU is mandatory for all quantitative determinations. To comply with the new requirement, a protocol was established in the authors' laboratory in 2001. The protocol has since evolved based on our practical experience, and a refined version was adopted in 2004. This paper describes our approach in establishing the MU, as well as some other important considerations, for the quantification of threshold substances in biological samples as applied in the area of doping control for horses. The testing of threshold substances can be viewed as a compliance test (or testing to a specified limit). As such, it should only be necessary to establish the MU at the threshold level. The steps in a "Bottom-Up" approach adopted by us are similar to those described in the EURACHEM/CITAC guide, "Quantifying Uncertainty in Analytical Measurement". They involve first specifying the measurand, including the relationship between the measurand and the input quantities upon which it depends. This is followed by identifying all applicable uncertainty contributions using a "cause and effect" diagram. The magnitude of each uncertainty component is then calculated and converted to a standard uncertainty. A recovery study is also conducted to determine if the method bias is significant and whether a recovery (or correction) factor needs to be applied. All standard uncertainties with values greater than 30% of the largest one are then used to derive the combined standard uncertainty. Finally, an expanded uncertainty is calculated at 99% one-tailed confidence level by multiplying the standard uncertainty with an appropriate coverage factor (k). A sample is considered positive if the determined concentration of the threshold substance exceeds its threshold by the expanded uncertainty. In addition, other important considerations, which can have a significant impact on quantitative analyses, will be presented.

  15. Joint Air-to-Surface Standoff Missile (JASSM)

    DTIC Science & Technology

    2015-12-01

    6.1.3) All Ops All Ops Joint Critical Ops All Ops All Ops Missile Reliability (KSA) (CPD para 6.2.8) 4th Lot .91 4th Lot .91 IOT &E .80 4th Lot .85 IOT &E...the ORD 303-95-III dated January 20, 2004 Change Explanations None Acronyms and Abbreviations IOT &E - Initial Operational Test and Evaluation KSA... Actuator Control Card, Lots 12 and 4 Systems Engineering Program Support/Program Tooling and Test Equipment, and JASSM-ER Standard Data Protocol (DS

  16. Individual differences in the forced swimming test and the effect of environmental enrichment: searching for an interaction.

    PubMed

    Sequeira-Cordero, A; Mora-Gallegos, A; Cuenca-Berger, P; Fornaguera-Trías, J

    2014-04-18

    Animals with low and high immobility in the forced swimming test (FST) differ in a number of neurobehavioral factors. A growing body of evidence suggests that the exposure to enriched environments mediates a number of changes in the brain. Therefore, we studied if animals' individuality can somehow modulate the response to environmental stimuli. Male rats were classified according to their immobility time scores in the FST test session as animals with low, medium or high immobility. Then, rats from groups with low and high immobility were randomly distributed in two groups to be reared in different housing conditions (i.e., enriched and standard conditions) during 8weeks. Animals were subjected to the open field test (OFT) before and 6weeks after the start of housing protocol. Rats with high immobility in the FST also showed high ambulation and high rearing time in the first OFT. Such findings were not observed in the second OFT. Conversely, an effect of environmental enrichment was found in the second OFT where enriched animals showed lower ambulation and higher grooming time than the standard control group. Rats were sacrificed after the housing protocol and neurochemical content and/or gene expression were studied in three different brain regions: the prefrontal cortex, the hippocampus and the nucleus accumbens. Rats with low immobility showed significantly higher accumbal 5-HT levels than animals with high immobility, whereas no neurochemical differences were observed between enriched and standard animals. Regarding expression data, however, an effect of enrichment on accumbal corticotropin-releasing factor (CRF) and its receptor 1 (CRFR1) levels was observed, and such effect depended on immobility levels. Thus, our results not only allowed us to identify a number of differences between animals with low and high immobility or animals housed in standard and enriched conditions, but also suggested that animals' individuality modulated in some way the response to environmental stimuli. Copyright © 2014 IBRO. Published by Elsevier Ltd. All rights reserved.

  17. User-oriented end-to-end transport protocols for the real-time distribution of telemetry data from NASA spacecraft

    NASA Technical Reports Server (NTRS)

    Hooke, A. J.

    1979-01-01

    A set of standard telemetry protocols for downlink data flow facilitating the end-to-end transport of instrument data from the spacecraft to the user in real time is proposed. The direct switching of data by autonomous message 'packets' that are assembled by the source instrument on the spacecraft is discussed. The data system consists thus of a format on a message rather than word basis, and such packet telemetry would include standardized protocol headers. Standards are being developed within the NASA End-to-End Data System (NEEDS) program for the source packet and transport frame protocols. The source packet protocol contains identification of both the sequence number of the packet as it is generated by the source and the total length of the packet, while the transport frame protocol includes a sequence count defining the serial number of the frame as it is generated by the spacecraft data system, and a field specifying any 'options' selected in the format of the frame itself.

  18. Evaluation of autonomous recording units for detecting 3 species of secretive marsh birds

    USGS Publications Warehouse

    Sidie-Slettehahl, Anna M.; Jensen, Kent C.; Johnson, Rex R.; Arnold, Todd W.; Austin, Jane; Stafford, Joshua D.

    2015-01-01

    Population status and habitat use of yellow rails (Coturnicops noveboracensis), Nelson's sparrows (Ammodramus nelsoni), and Le Conte's sparrows (A. leconteii) are poorly known, so standardized surveys of these species are needed to inform conservation planning and management. A protocol for monitoring secretive marsh birds exists; however, these species regularly call at night and may be missed during early morning surveys. We tested the effectiveness of autonomous recording units (hereafter, recording units) to survey these species by analyzing recorded vocalizations using bioacoustics software. We deployed 22 recording units at 54 sites in northern Minnesota and eastern North Dakota, USA, and conducted traditional broadcast surveys during May–June, 2010 and 2011. We compared detection probabilities between recording units and standard monitoring protocols using robust-design occupancy models. On average, recording units detected 0.59 (SE = 0.11) fewer Le Conte's sparrows, 0.76 (SE = 0.15) fewer Nelson's sparrows, and 1.01 (SE = 0.14) fewer yellow rails per survey than were detected using the standard protocol. Detection probabilities using the standard protocol averaged 0.95 (yellow rail; 95% CI = 0.86–0.98), 0.93 (Le Conte's sparrow; 95% CI = 0.78–0.98), and 0.89 (Nelson's sparrow; 95% CI = 0.56–0.98), but averaged 0.71 (yellow rail; 95% CI = 0.56–0.83), 0.61 (Le Conte's sparrow; 95% CI = 0.42–0.78), and 0.51 (Nelson's sparrow; 95% CI = 0.19–0.82) using recording units. Reduced detection by recording units was likely due to the ability of human listeners to identify birds calling at greater distances. Recording units may be effective for surveying nocturnal secretive marsh birds if investigators correct for differential detectability. Reduced detectability may be outweighed by the increased spatial and temporal coverage feasible with recording units.

  19. Effectiveness of various irrigation protocols for the removal of calcium hydroxide from artificial standardized grooves

    PubMed Central

    GOKTURK, Hakan; OZKOCAK, Ismail; BUYUKGEBIZ, Feyzi; DEMIR, Osman

    2017-01-01

    Abstract Objective The aim of this study was to investigate the ability of laser-activated irrigation (LAI), XP-endo Finisher, CanalBrush, Vibringe, passive ultrasonic irrigation (PUI), and conventional syringe irrigation systems on the removal of calcium hydroxide (CH) from simulated root canal irregularities. Material and Methods The root canals of one hundred and five extracted single-rooted teeth were instrumented using Reciproc rotary files up to size R40. The teeth were split longitudinally. Two of the three standard grooves were created in the coronal and apical section of one segment, and another in the middle part of the second segment. The standardized grooves were filled with CH and the root halves were reassembled. After 14 days, the specimens were randomly divided into 7 experimental groups (n=15/group). CH was removed as follows: Group 1: beveled needle irrigation; Group 2: double side-vented needle irrigation; Group 3: CanalBrush; Group 4: XP-endo Finisher; Group 5: Vibringe; Group 6: PUI; Group 7: LAI. The amount of remaining CH in the grooves was scored under a stereomicroscope at 20× magnification. Statistical evaluation was performed using Kruskal–Wallis and Bonferroni-Correction Mann–Whitney U tests. Results Groups 1 and 2 were the least efficient in eliminating CH from the grooves. Groups 6 and 7 eliminated more CH than the other protocols; however, no significant differences were found between these two groups (P>.05). Conclusions Nevertheless, none of the investigated protocols were able to completely remove all CH from all three root regions. LAI and PUI showed less residual CH than the other protocols from artificial grooves. PMID:28678948

  20. Development of a new clot formation protocol for standardized in vitro investigations of sonothrombolysis.

    PubMed

    Roessler, Florian C; Teichert, Andrea; Ohlrich, Marcus; Marxsen, Jan H; Stellmacher, Florian; Tanislav, Christian; Seidel, Günter

    2014-11-30

    Agreement about the most suitable clot formation protocol for sonothrombolysis investigations is lacking. Lysis rates vary strongly owing to different test conditions and, thus, cannot be compared. We aim to establish a simple but physiologically grounded protocol for in vitro coagulation to enable standardized sonothrombolysis investigations. Clots were generated from platelet-rich plasma (PRP) obtained by centrifugation (10 min, 180 × g) of human venous blood (VB). PRP was mixed with the boundary layer formed between the supernatant and the erythrocyte layer. To achieve clots with different platelet counts, PRP was gradually substituted with platelet-free plasma (PFP), harvested from the supernatant of VB after centrifugation (10 min, 2570 × g). Clot types were examined for histological appearance, hydrodynamic resistance under physiological flows, and lysis rate measured by weight loss after a 2-h treatment with recombinant tissue plasminogen activator (rt-PA) (60 kU/ml). Lysis rates of the most suitable clot were measured after a 1-h treatment with rt-PA (60 kU/ml), and combined treatment with rt-PA and 2-MHz transcranial color-coded sonography (TCCS) (0.179 W/cm(2)) or 2-MHz transcranial Doppler (TCD) (0.457 W/cm(2)). With increased platelet count, the hydrodynamic resistance of the artificial clots increased, their histological appearance became more physiological, and lysis rates decreased. The most suitable clots consisted of 1.5-ml PRP, 2.0-ml PFP, and 0.5-ml boundary layer. Their lysis rates were 36.7 ± 7.8% (rt-PA), 40.8 ± 8.6% (rt-PA+TCCS), and 40.4 ± 8.3% (rt-PA+TCD). These systemic investigations were conducted for the first time. This protocol should be used for standardized sonothrombolysis investigations. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Standardizing Nasal Nitric Oxide Measurement as a Test for Primary Ciliary Dyskinesia

    PubMed Central

    Hazucha, Milan J.; Chawla, Kunal K.; Baker, Brock R.; Shapiro, Adam J.; Brown, David E.; LaVange, Lisa M.; Horton, Bethany J.; Qaqish, Bahjat; Carson, Johnny L.; Davis, Stephanie D.; Dell, Sharon D.; Ferkol, Thomas W.; Atkinson, Jeffrey J.; Olivier, Kenneth N.; Sagel, Scott D.; Rosenfeld, Margaret; Milla, Carlos; Lee, Hye-Seung; Krischer, Jeffrey; Zariwala, Maimoona A.; Knowles, Michael R.

    2013-01-01

    Rationale: Several studies suggest that nasal nitric oxide (nNO) measurement could be a test for primary ciliary dyskinesia (PCD), but the procedure and interpretation have not been standardized. Objectives: To use a standard protocol for measuring nNO to establish a disease-specific cutoff value at one site, and then validate at six other sites. Methods: At the lead site, nNO was prospectively measured in individuals later confirmed to have PCD by ciliary ultrastructural defects (n = 143) or DNAH11 mutations (n = 6); and in 78 healthy and 146 disease control subjects, including individuals with asthma (n = 37), cystic fibrosis (n = 77), and chronic obstructive pulmonary disease (n = 32). A disease-specific cutoff value was determined, using generalized estimating equations (GEEs). Six other sites prospectively measured nNO in 155 consecutive individuals enrolled for evaluation for possible PCD. Measurements and Main Results: At the lead site, nNO values in PCD (mean ± standard deviation, 20.7 ± 24.1 nl/min; range, 1.5–207.3 nl/min) only rarely overlapped with the nNO values of healthy control subjects (304.6 ± 118.8; 125.5–867.0 nl/min), asthma (267.8 ± 103.2; 125.0–589.7 nl/min), or chronic obstructive pulmonary disease (223.7 ± 87.1; 109.7–449.1 nl/min); however, there was overlap with cystic fibrosis (134.0 ± 73.5; 15.6–386.1 nl/min). The disease-specific nNO cutoff value was defined at 77 nl/minute (sensitivity, 0.98; specificity, >0.999). At six other sites, this cutoff identified 70 of the 71 (98.6%) participants with confirmed PCD. Conclusions: Using a standardized protocol in multicenter studies, nNO measurement accurately identifies individuals with PCD, and supports its usefulness as a test to support the clinical diagnosis of PCD. PMID:24024753

  2. Standardization of Protocol for the Sampling, Testing and abatement of Asbestos Containing Joint Compound

    DTIC Science & Technology

    1994-09-01

    vi A b stract...5-2 Proposed Decision Tree for ACJC Abatement Activities 5-10 Vi AFIT/GEE/ENV/94S-23 ABSTRACT This study investigated the differing regulatory...specific amount. According to 29 CFR 1910.58(k)(2)( vi )(B), labeling provisions do not apply unless asbestos is present in a product in concentrations

  3. A Standardized Inoculation Protocol to Test Wheat Cultivars for Reaction to Head Blast caused by Magnaporthe oryzae (Triticum pathotype)

    USDA-ARS?s Scientific Manuscript database

    Wheat blast, caused by the Triticum pathotype of M. oryzae (MoT), poses a significant threat to wheat production worldwide. Because this pathotype does not occur in the U.S., it is important to prepare for its possible introduction. As part of this preparation, over 500 U.S. wheat cultivars were tes...

  4. Understanding Definitions of Minimally Verbal across Instruments: Evidence for Subgroups within Minimally Verbal Children and Adolescents with Autism Spectrum Disorder

    ERIC Educational Resources Information Center

    Bal, Vanessa Hus; Katz, Terry; Bishop, Somer L.; Krasileva, Kate

    2016-01-01

    Background: Minimally verbal (MV) children with autism spectrum disorder (ASD) are often assumed to be profoundly cognitively impaired and excluded from analyses due to challenges completing standardized testing protocols. A literature aimed at increasing understanding of this subgroup is emerging; however, the many methods used to define MV…

  5. Comparison of Conversation, Freeplay, and Story Generation as Methods of Language Sample Elicitation.

    ERIC Educational Resources Information Center

    Southwood, Frenette; Russell, Ann F.

    2004-01-01

    The spontaneous language sample forms an important part of the language evaluation protocol (M. Dunn, J. Flax, M. Sliwinski, & D. Aram, 1996; J. L. Evans & H. K. Craig, 1992; L. E. Evans & J. Miller, 1999) because of the limitations of standardized language tests and their unavailability in certain languages, such as Afrikaans. This study examined…

  6. The Social Dimension of Stress: Experimental Manipulations of Social Support and Social Identity in the Trier Social Stress Test

    PubMed Central

    Frisch, Johanna U.; Häusser, Jan A.; van Dick, Rolf; Mojzisch, Andreas

    2015-01-01

    In many situations humans are influenced by the behavior of other people and their relationships with them. For example, in stressful situations supportive behavior of other people as well as positive social relationships can act as powerful resources to cope with stress. In order to study the interplay between these variables, this protocol describes two effective experimental manipulations of social relationships and supportive behavior in the laboratory. In the present article, these two manipulations are implemented in the Trier Social Stress Test (TSST)—a standard stress induction paradigm in which participants are subjected to a simulated job interview. More precisely, we propose (a) a manipulation of the relationship between different protagonists in the TSST by making a shared social identity salient and (b) a manipulation of the behavior of the TSST-selection committee, which acts either supportively or unsupportively. These two experimental manipulations are designed in a modular fashion and can be applied independently of each other but can also be combined. Moreover, these two manipulations can also be integrated into other stress protocols and into other standardized social interactions such as trust games, negotiation tasks, or other group tasks. PMID:26649856

  7. Efficient production of erythroid, megakaryocytic and myeloid cells, using single cell-derived iPSC colony differentiation.

    PubMed

    Hansen, Marten; Varga, Eszter; Aarts, Cathelijn; Wust, Tatjana; Kuijpers, Taco; von Lindern, Marieke; van den Akker, Emile

    2018-04-28

    Hematopoietic differentiation of human induced pluripotent stem cells (iPSCs) provide opportunities not only for fundamental research and disease modelling/drug testing but also for large-scale production of blood effector cells for future clinical application. Although there are multiple ways to differentiate human iPSCs towards hematopoietic lineages, there is a need to develop reproducible and robust protocols. Here we introduce an efficient way to produce three major blood cell types using a standardized differentiation protocol that starts with a single hematopoietic initiation step. This system is feeder-free, avoids EB-formation, starts with a hematopoietic initiation step based on a novel single cell-derived iPSC colony differentiation and produces multi-potential progenitors within 8-10 days. Followed by lineage-specific growth factor supplementation these cells can be matured into well characterized erythroid, megakaryocytic and myeloid cells with high-purity, without transcription factor overexpression or any kind of pre-purification step. This standardized differentiation system provides a simple platform to produce specific blood cells in a reproducible manner for hematopoietic development studies, disease modelling, drug testing and the potential for future therapeutic applications. Copyright © 2018. Published by Elsevier B.V.

  8. SpaceWire Protocol ID: What Does It Mean To You?

    NASA Technical Reports Server (NTRS)

    Rakow, Glenn; Schnurr, Richard; Gilley, Daniel; Parks, Steve

    2006-01-01

    Spacewire is becoming a popular solution for satellite high-speed data buses because it is a simple standard that provides great flexibility for a wide range of system requirements. It is simple in packet format and protocol, allowing users to easily tailor their implementation for their specific application. Some of the attractive aspects of Spacewire that make it easy to implement also make it hard for future reuse. Protocol reuse is difficult because Spacewire does not have a defined mechanism to communicate with the higher layers of the protocol stack. This has forced users of Spacewire to define unique packet formats and define how these packets are to be processed. Each mission writes their own Interface Control Document (ICD) and tailors Spacewire for their specific requirements making reuse difficult. Part of the reason for this habit may be because engineers typically optimize designs for their own requirements in the absence of a standard. This is an inefficient use of project resources and costs more to develop missions. A new packet format for Spacewire has been defined as a solution for this problem. This new packet format is a compliment to the Spacewire standard that will support protocol development upon Spacewire. The new packet definition does not replace the current packet structure, i.e., does not make the standard obsolete, but merely extends the standard for those who want to develop protocols over Spacewire. The Spacewire packet is defined with the first part being the Destination Address, which may be one or more bytes. This is followed by the packet cargo, which is user defined. The cargo is truncated with an End-Of-Packet (EOP) marker. This packet structure offers low packet overhead and allows the user to define how the contents are to be formatted. It also provides for many different addressing schemes, which provide flexibility in the system. This packet flexibility is typically an attractive part of the Spacewire. The new extended packet format adds one new field to the packet that greatly enhances the capability of Spacewire. This new field called the Protocol Identifier (ID) is used to identify the packet contents and the associated processing for the packet. This feature along with the restriction in the packet format that uses the Protocol ID, allows a deterministic method of decoding packets that was not before possible. The first part of the packet is still the Destination Address, which still conforms to the original standard but with one restriction. The restriction is that the first byte seen at the destination by the user needs to be a logical address, independent of the addressing scheme used. The second field is defined as the Protocol ID, which is usually one byte in length. The packet cargo (user defined) follows the Protocol ID. After the packet cargo is the EOP, which defines the end of packet. The value of the Protocol ID is assigned by the Spacewire working group and the protocol description published for others to use. The development of Protocols for Spacewire is currently the area of greatest activity by the Spacewire working group. The first protocol definition by the working group has been completed and is now in the process of formal standardization. There are many other protocols in development for missions that have not yet received formal Protocol ID assignment, but even if the protocols are not formally assigned a value, this effort will provide synergism for future developments.

  9. Government Open Systems Interconnection Profile (GOSIP) Transition Strategy

    DTIC Science & Technology

    1993-09-01

    it explores some of the GOSIP protocol details and discusses the process by which standards organizations have developed their...version 1 and 2. Additionally, it explores some of the GOSIP protocol details and discusses the process by which standards organizations have developed ...ORGANIZATION OF STUDY 1. The Standards Process Chapter II describes the process whereby standards are developed and adopted by the ISO and how the

  10. Writing standard operating procedures (SOPs) for cryostorage protocols: using shoot meristem cryopreservation as an example.

    PubMed

    Harding, Keith; Benson, Erica E

    2015-01-01

    Standard operating procedures are a systematic way of making sure that biopreservation processes, tasks, protocols, and operations are correctly and consistently performed. They are the basic documents of biorepository quality management systems and are used in quality assurance, control, and improvement. Methodologies for constructing workflows and writing standard operating procedures and work instructions are described using a plant cryopreservation protocol as an example. This chapter is pertinent to other biopreservation sectors because how methods are written, interpreted, and implemented can affect the quality of storage outcomes.

  11. Testing for EMC (electromagnetic compatibility) in the clinical environment.

    PubMed

    Paperman, D; David, Y; Martinez, M

    1996-01-01

    Testing for electromagnetic compatibility (EMC) in the clinical environment introduces a host of complex conditions not normally encountered under laboratory conditions. In the clinical environment, various radio-frequency (RF) sources of electromagnetic interference (EMI) may be present throughout the entire spectrum of interest. Isolating and analyzing the impact from the sources of interference to medical devices involves a multidisciplinary approach based on training in, and knowledge of, the following: operation of medical devices and their susceptibility to EMI; RF propagation modalities and interaction theory; spectrum analysis systems and techniques (preferably with signature analysis capabilities) and calibrated antennas; the investigation methodology of suspected EMC problems, and testing protocols and standards. Using combinations of standard test procedures adapted for the clinical environment with personnel that have an understanding of radio-frequency behavior increases the probability of controlling, proactively, EMI in the clinical environment, thus providing for a safe and more effective patient care environment.

  12. The prevalence of reversible airway obstruction in professional football players.

    PubMed

    Ross, R G

    2000-12-01

    To determine the prevalence of reversible airway obstruction in a group of professional football training camp participants. All attendees at a Canadian Football League team rookie preseason training camp were invited to participate in a protocol designed to elicit symptoms and signs of reversible airway obstruction (asthma) during the initial preparticipation examination. Those agreeing to the protocol completed a questionnaire containing standardized inquiries about a past history of asthma and the presence of symptoms. Participants then underwent spirometry testing to determine lung function before and after receiving a standardized dose of bronchodilator medication. Players showing evidence of airway obstruction during initial testing and still on the team roster underwent repeat spirometry testing and formal pulmonary function testing during the football season. The follow-up pulmonary function tests were performed to determine those that might benefit from treatment for asthma. Nineteen of 34 (56%) players agreeing to participate had significant reversible airway obstruction as defined by a 12% or greater reversibility in forced expiratory volume in one second (FEV1), peak expiratory flow rate (PEFR), and/or forced expiratory flow rate between 25 and 75% of forced vital capacity (FEF 25-75). In most participants, the diagnosis was made on the basis of spirometry alone. Of those testing positive during initial inquiry, 88% remained positive on repeat spirometry, and 73% had reversible airway obstruction during more stringently controlled hospital-based pulmonary function testing. Those players treated for previously undiagnosed asthma noted an improvement in subjective athletic performance during the football season. Based on the remarkably high prevalence of undiagnosed asthma in this group, it may prove worthwhile to test elite football players using lung function parameters.

  13. Infrastructure and the Virtual Observatory

    NASA Astrophysics Data System (ADS)

    Dowler, P.; Gaudet, S.; Schade, D.

    2011-07-01

    The modern data center is faced with architectural and software engineering challenges that grow along with the challenges facing observatories: massive data flow, distributed computing environments, and distributed teams collaborating on large and small projects. By using VO standards as key components of the infrastructure, projects can take advantage of a decade of intellectual investment by the IVOA community. By their nature, these standards are proven and tested designs that already exist. Adopting VO standards saves considerable design effort, allows projects to take advantage of open-source software and test suites to speed development, and enables the use of third party tools that understand the VO protocols. The evolving CADC architecture now makes heavy use of VO standards. We show examples of how these standards may be used directly, coupled with non-VO standards, or extended with custom capabilities to solve real problems and provide value to our users. In the end, we use VO services as major parts of the core infrastructure to reduce cost rather than as an extra layer with additional cost and we can deliver more general purpose and robust services to our user community.

  14. Coagulation changes during lower body negative pressure and blood loss in humans.

    PubMed

    van Helmond, Noud; Johnson, Blair D; Curry, Timothy B; Cap, Andrew P; Convertino, Victor A; Joyner, Michael J

    2015-11-01

    We tested the hypothesis that markers of coagulation activation are greater during lower body negative pressure (LBNP) than those obtained during blood loss (BL). We assessed coagulation using both standard clinical tests and thrombelastography (TEG) in 12 men who performed a LBNP and BL protocol in a randomized order. LBNP consisted of 5-min stages at 0, -15, -30, and -45 mmHg of suction. BL included 5 min at baseline and following three stages of 333 ml of blood removal (up to 1,000 ml total). Arterial blood draws were performed at baseline and after the last stage of each protocol. We found that LBNP to -45 mmHg is a greater central hypovolemic stimulus versus BL; therefore, the coagulation markers were plotted against central venous pressure (CVP) to obtain stimulus-response relationships using the linear regression line slopes for both protocols. Paired t-tests were used to determine whether the slopes of these regression lines fell on similar trajectories for each protocol. Mean regression line slopes for coagulation markers versus CVP fell on similar trajectories during both protocols, except for TEG α° angle (-0.42 ± 0.96 during LBNP vs. -2.41 ± 1.13°/mmHg during BL; P < 0.05). During both LBNP and BL, coagulation was accelerated as evidenced by shortened R-times (LBNP, 9.9 ± 2.4 to 6.2 ± 1.1; BL, 8.7 ± 1.3 to 6.4 ± 0.4 min; both P < 0.05). Our results indicate that LBNP models the general changes in coagulation markers observed during BL. Copyright © 2015 the American Physiological Society.

  15. Exercise counteracts fatty liver disease in rats fed on fructose-rich diet

    PubMed Central

    2010-01-01

    Background This study aimed to analyze the effects of exercise at the aerobic/anaerobic transition on the markers of non-alcoholic fatty liver disease (NAFLD), insulin sensitivity and the blood chemistry of rats kept on a fructose-rich diet. Methods We separated 48 Wistar rats into two groups according to diet: a control group (balanced diet AIN-93 G) and a fructose-rich diet group (60% fructose). The animals were tested for maximal lactate-steady state (MLSS) in order to identify the aerobic/anaerobic metabolic transition during swimming exercises at 28 and 90 days of age. One third of the animals of each group were submitted to swimming training at an intensity equivalent to the individual MLSS for 1 hours/day, 5 days/week from 28 to 120 days (early protocol). Another third were submitted to the training from 90 to 120 days (late protocol), and the others remained sedentary. The main assays performed included an insulin tolerance test (ITT) and tests of serum alanine aminotransferase [ALT] and aspartate aminotransferase [AST] activities, serum triglyceride concentrations [TG] and liver total lipid concentrations. Results The fructose-fed rats showed decreased insulin sensitivity, and the late-exercise training protocol counteracted this alteration. There was no difference between the groups in levels of serum ALT, whereas AST and liver lipids increased in the fructose-fed sedentary group when compared with the other groups. Serum triglycerides concentrations were higher in the fructose-fed trained groups when compared with the corresponding control group. Conclusions The late-training protocol was effective in restoring insulin sensitivity to acceptable standards. Considering the markers here evaluated, both training protocols were successful in preventing the emergence of non-alcoholic fatty liver status disease. PMID:20946638

  16. Accelerated rehabilitation compared with a standard protocol after distal radial fractures treated with volar open reduction and internal fixation: a prospective, randomized, controlled study.

    PubMed

    Brehmer, Jess L; Husband, Jeffrey B

    2014-10-01

    There are relatively few studies in the literature that specifically evaluate accelerated rehabilitation protocols for distal radial fractures treated with open reduction and internal fixation (ORIF). The purpose of this study was to compare the early postoperative outcomes (at zero to twelve weeks postoperatively) of patients enrolled in an accelerated rehabilitation protocol with those of patients enrolled in a standard rehabilitation protocol following ORIF for a distal radial fracture. We hypothesized that patients with accelerated rehabilitation after volar ORIF for a distal radial fracture would have an earlier return to function compared with patients who followed a standard protocol. From November 2007 to November 2010, eighty-one patients with an unstable distal radial fracture were prospectively randomized to follow either an accelerated or a standard rehabilitation protocol after undergoing ORIF with a volar plate for a distal radial fracture. Both groups began with gentle active range of motion at three to five days postoperatively. At two weeks, the accelerated group initiated wrist/forearm passive range of motion and strengthening exercises, whereas the standard group initiated passive range of motion and strengthening at six weeks postoperatively. Patients were assessed at three to five days, two weeks, three weeks, four weeks, six weeks, eight weeks, twelve weeks, and six months postoperatively. Outcomes included Disabilities of the Arm, Shoulder and Hand (DASH) scores (primary outcome) and measurements of wrist flexion/extension, supination, pronation, grip strength, and palmar pinch. The patients in the accelerated group had better mobility, strength, and DASH scores at the early postoperative time points (zero to eight weeks postoperatively) compared with the patients in the standard rehabilitation group. The difference between the groups was both clinically relevant and statistically significant. Patients who follow an accelerated rehabilitation protocol that emphasizes motion immediately postoperatively and initiates strengthening at two weeks after volar ORIF of a distal radial fracture have an earlier return to function than patients who follow a more standard rehabilitation protocol. Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.

  17. A protocol using coho salmon to monitor Tongass National Forest Land and Resource Management Plan standards and guidelines for fish habitat.

    Treesearch

    M.D. Bryant; Trent McDonald; R. Aho; B.E. Wright; Michelle Bourassa Stahl

    2008-01-01

    We describe a protocol to monitor the effectiveness of the Tongass Land Management Plan (TLMP) management standards for maintaining fish habitat. The protocol uses juvenile coho salmon (Oncorhynchus kisutch) in small tributary streams in forested watersheds. We used a 3-year pilot study to develop detailed methods to estimate juvenile salmonid...

  18. A universal standard for the validation of blood pressure measuring devices: Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Collaboration Statement.

    PubMed

    Stergiou, George S; Alpert, Bruce; Mieke, Stephan; Asmar, Roland; Atkins, Neil; Eckert, Siegfried; Frick, Gerhard; Friedman, Bruce; Graßl, Thomas; Ichikawa, Tsutomu; Ioannidis, John P; Lacy, Peter; McManus, Richard; Murray, Alan; Myers, Martin; Palatini, Paolo; Parati, Gianfranco; Quinn, David; Sarkis, Josh; Shennan, Andrew; Usuda, Takashi; Wang, Jiguang; Wu, Colin O; O'Brien, Eoin

    2018-03-01

    : In the last 30 years, several organizations, such as the US Association for the Advancement of Medical Instrumentation (AAMI), the British Hypertension Society, the European Society of Hypertension (ESH) Working Group on Blood Pressure (BP) Monitoring and the International Organization for Standardization (ISO) have developed protocols for clinical validation of BP measuring devices. However, it is recognized that science, as well as patients, consumers and manufacturers would be best served if all BP measuring devices were assessed for accuracy according to an agreed single validation protocol that had global acceptance. Therefore, an international initiative was taken by AAMI, ESH and ISO experts who agreed to develop a universal standard for device validation. This statement presents the key aspects of a validation procedure, which were agreed by the AAMI, ESH and ISO representatives as the basis for a single universal validation protocol. As soon as the AAMI/ESH/ISO standard is fully developed, this will be regarded as the single universal standard and will replace all other previous standards/protocols.

  19. A Universal Standard for the Validation of Blood Pressure Measuring Devices: Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Collaboration Statement.

    PubMed

    Stergiou, George S; Alpert, Bruce; Mieke, Stephan; Asmar, Roland; Atkins, Neil; Eckert, Siegfried; Frick, Gerhard; Friedman, Bruce; Graßl, Thomas; Ichikawa, Tsutomu; Ioannidis, John P; Lacy, Peter; McManus, Richard; Murray, Alan; Myers, Martin; Palatini, Paolo; Parati, Gianfranco; Quinn, David; Sarkis, Josh; Shennan, Andrew; Usuda, Takashi; Wang, Jiguang; Wu, Colin O; O'Brien, Eoin

    2018-03-01

    In the past 30 years, several organizations, such as the US Association for the Advancement of Medical Instrumentation (AAMI), the British Hypertension Society, the European Society of Hypertension (ESH) Working Group on Blood Pressure (BP) Monitoring, and the International Organization for Standardization (ISO), have developed protocols for clinical validation of BP measuring devices. However, it is recognized that science, as well as patients, consumers, and manufacturers, would be best served if all BP measuring devices were assessed for accuracy according to an agreed single validation protocol that had global acceptance. Therefore, an international initiative was taken by the AAMI, ESH, and ISO experts who agreed to develop a universal standard for device validation. This statement presents the key aspects of a validation procedure, which were agreed by the AAMI, ESH, and ISO representatives as the basis for a single universal validation protocol. As soon as the AAMI/ESH/ISO standard is fully developed, this will be regarded as the single universal standard and will replace all other previous standards/protocols. © 2018 American Heart Association, Inc., and Wolters Kluwer Health, Inc.

  20. National Airspace System (NAS) open system architecture and protocols

    DOT National Transportation Integrated Search

    2003-08-14

    This standard establishes the open systems data communications architecture and authorized protocol standards for the National Airspace System (NAS). The NAS will consist of various types of processors and communications networks procured from a vari...

  1. [Compliance with current standards for the early detection of neonatal hearing loss].

    PubMed

    Rojas-Godoy, Andrea L; Gómez-Gómez, Olga; Rivas-Muñoz, Fabio A

    2014-01-01

    Assessing compliance with the section "Assessment of hearing" stipulated in the Technical Standard to Detect Alteration in children aged less than 10 years-old in Bogota. This was a cross-sectional study which involved reviewing the medical records of all children born between July 1st and December 31st 2010 in two healthcare institutions in Bogota. Records were selected in which any of the following risk factors appeared: neonatal hyperbilirubinaemia involving phototherapy, neonatal exposure to ototoxic substances and/or <1.500 gr low birth weight. It was also ascertained whether children had been referred to an auditory evoked potential test as the prescribed screening test for neonatal hearing, as stipulated in mandatory Colombian technical standards for detecting abnormal growth and developmental in children aged less than ten years-old. Neither of the two institutions was making the aforementioned referral test. The results indicated significant difficulties in adherence to the protocol for the early detection of hearing loss regarding pertinent/current neonatal Colombian regulations.

  2. Feasibility of remote administration of the Fundamentals of Laparoscopic Surgery (FLS) skills test.

    PubMed

    Okrainec, Allan; Vassiliou, Melina; Kapoor, Andrew; Pitzul, Kristen; Henao, Oscar; Kaneva, Pepa; Jackson, Timothy; Ritter, E Matt

    2013-11-01

    Fundamentals of Laparoscopic Surgery (FLS) certification testing currently is offered at accredited test centers or at select surgical conferences. Maintaining these test centers requires considerable investment in human and financial resources. Additionally, it can be challenging for individuals outside North America to become FLS certified. The objective of this pilot study was to assess the feasibility of remotely administering and scoring the FLS examination using live videoconferencing compared with standard onsite testing. This parallel mixed-methods study used both FLS scoring data and participant feedback to determine the barriers to feasibility of remote proctoring for the FLS examination. Participants were tested at two accredited FLS testing centers. An official FLS proctor administered and scored the FLS exam remotely while another onsite proctor provided a live score of participants' performance. Participant feedback was collected during testing. Interrater reliabilities of onsite and remote FLS scoring data were compared using intraclass correlation coefficients (ICCs). Participant feedback was analyzed using modified grounded theory to identify themes for barriers to feasibility. The scores of the remote and onsite proctors showed excellent interrater reliability in the total FLS (ICC 0.995, CI [0.985-0.998]). Several barriers led to critical errors in remote scoring, but most were accompanied by a solution incorporated into the study protocol. The most common barrier was the chain of custody for exam accessories. The results of this pilot study suggest that remote administration of the FLS has the potential to decrease costs without altering test-taker scores or exam validity. Further research is required to validate protocols for remote and onsite proctors and to direct execution of these protocols in a controlled environment identical to current FLS test administration.

  3. Electric Vehicle Communications Standards Testing and Validation - Phase II: SAE J2931/1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pratt, Richard M.; Gowri, Krishnan

    Vehicle to grid communication standards enable interoperability among vehicles, charging stations and utility providers and provide the capability to implement charge management. Several standards initiatives by the Society of Automobile Engineers (SAE), International Standards Organization and International Electrotechnical Commission (ISO/IEC), and ZigBee/HomePlug Alliance are developing requirements for communication messages and protocols. Recent work by the Electric Power Research Institute (EPRI) in collaboration with SAE and automobile manufacturers has identified vehicle to grid communication performance requirements and developed a test plan as part of SAE J2931/1 committee work. This laboratory test plan was approved by the SAE J2931/1 committee and includedmore » test configurations, test methods, and performance requirements to verify reliability, robustness, repeatability, maximum communication distance, and authentication features of power line carrier (PLC) communication modules at the internet protocol layer level. The goal of the testing effort was to select a communication technology that would enable automobile manufacturers to begin the development and implementation process. The EPRI/Argonne National Laboratory (ANL)/Pacific Northwest National Laboratory (PNNL) testing teams divided the testing so that results for each test could be presented by two teams, performing the tests independently. The PNNL team performed narrowband PLC testing including the Texas Instruments (TI) Concerto, Ariane Controls AC-CPM1, and the MAXIM Tahoe 2 evaluation boards. The scope of testing was limited to measuring the vendor systems communication performance between Electric Vehicle Support Equipment (EVSE) and plug-in electric vehicles (PEV). The testing scope did not address PEV’s CAN bus to PLC or PLC to EVSE (Wi-Fi, cellular, PLC Mains, etc.) communication integration. In particular, no evaluation was performed to delineate the effort needed to translate the IPv6/SEP2.0 messages to PEV’s CAN bus. The J2931/1 laboratory test results were presented to the SAE membership on March 20-22, 2012. The SAE committee decided to select HomePlug GreenPHY (HPGP) as the communication technology to use between the PEV and EVSE. No technology completely met all performance requirements. Both the MAXIM Tahoe 2 and TI Concerto met the 100Kbps throughput requirement, are estimated to meet the latency measurement performance, and met the control pilot impairment requirements. But HPGP demonstrated the potential to provide a data throughput rate of 10x of the requirement and either met or showed the potential to meet the other requirements with further development.« less

  4. Establishment of a Universal Size Standard Strain for Use with the PulseNet Standardized Pulsed-Field Gel Electrophoresis Protocols: Converting the National Databases to the New Size Standard

    PubMed Central

    Hunter, Susan B.; Vauterin, Paul; Lambert-Fair, Mary Ann; Van Duyne, M. Susan; Kubota, Kristy; Graves, Lewis; Wrigley, Donna; Barrett, Timothy; Ribot, Efrain

    2005-01-01

    The PulseNet National Database, established by the Centers for Disease Control and Prevention in 1996, consists of pulsed-field gel electrophoresis (PFGE) patterns obtained from isolates of food-borne pathogens (currently Escherichia coli O157:H7, Salmonella, Shigella, and Listeria) and textual information about the isolates. Electronic images and accompanying text are submitted from over 60 U.S. public health and food regulatory agency laboratories. The PFGE patterns are generated according to highly standardized PFGE protocols. Normalization and accurate comparison of gel images require the use of a well-characterized size standard in at least three lanes of each gel. Originally, a well-characterized strain of each organism was chosen as the reference standard for that particular database. The increasing number of databases, difficulty in identifying an organism-specific standard for each database, the increased range of band sizes generated by the use of additional restriction endonucleases, and the maintenance of many different organism-specific strains encouraged us to search for a more versatile and universal DNA size marker. A Salmonella serotype Braenderup strain (H9812) was chosen as the universal size standard. This strain was subjected to rigorous testing in our laboratories to ensure that it met the desired criteria, including coverage of a wide range of DNA fragment sizes, even distribution of bands, and stability of the PFGE pattern. The strategy used to convert and compare data generated by the new and old reference standards is described. PMID:15750058

  5. The touchscreen operant platform for testing learning and memory in rats and mice.

    PubMed

    Horner, Alexa E; Heath, Christopher J; Hvoslef-Eide, Martha; Kent, Brianne A; Kim, Chi Hun; Nilsson, Simon R O; Alsiö, Johan; Oomen, Charlotte A; Holmes, Andrew; Saksida, Lisa M; Bussey, Timothy J

    2013-10-01

    An increasingly popular method of assessing cognitive functions in rodents is the automated touchscreen platform, on which a number of different cognitive tests can be run in a manner very similar to touchscreen methods currently used to test human subjects. This methodology is low stress (using appetitive rather than aversive reinforcement), has high translational potential and lends itself to a high degree of standardization and throughput. Applications include the study of cognition in rodent models of psychiatric and neurodegenerative diseases (e.g., Alzheimer's disease, schizophrenia, Huntington's disease, frontotemporal dementia), as well as the characterization of the role of select brain regions, neurotransmitter systems and genes in rodents. This protocol describes how to perform four touchscreen assays of learning and memory: visual discrimination, object-location paired-associates learning, visuomotor conditional learning and autoshaping. It is accompanied by two further protocols (also published in this issue) that use the touchscreen platform to assess executive function, working memory and pattern separation.

  6. A 96-well-plate-based optical method for the quantitative and qualitative evaluation of Pseudomonas aeruginosa biofilm formation and its application to susceptibility testing.

    PubMed

    Müsken, Mathias; Di Fiore, Stefano; Römling, Ute; Häussler, Susanne

    2010-08-01

    A major reason for bacterial persistence during chronic infections is the survival of bacteria within biofilm structures, which protect cells from environmental stresses, host immune responses and antimicrobial therapy. Thus, there is concern that laboratory methods developed to measure the antibiotic susceptibility of planktonic bacteria may not be relevant to chronic biofilm infections, and it has been suggested that alternative methods should test antibiotic susceptibility within a biofilm. In this paper, we describe a fast and reliable protocol for using 96-well microtiter plates for the formation of Pseudomonas aeruginosa biofilms; the method is easily adaptable for antimicrobial susceptibility testing. This method is based on bacterial viability staining in combination with automated confocal laser scanning microscopy. The procedure simplifies qualitative and quantitative evaluation of biofilms and has proven to be effective for standardized determination of antibiotic efficiency on P. aeruginosa biofilms. The protocol can be performed within approximately 60 h.

  7. MicroSEQ® Salmonella spp. Detection Kit Using the Pathatrix® 10-Pooling Salmonella spp. Kit Linked Protocol Method Modification.

    PubMed

    Wall, Jason; Conrad, Rick; Latham, Kathy; Liu, Eric

    2014-03-01

    Real-time PCR methods for detecting foodborne pathogens offer the advantages of simplicity and quick time to results compared to traditional culture methods. The addition of a recirculating pooled immunomagnetic separation method prior to real-time PCR analysis increases processing output while reducing both cost and labor. This AOAC Research Institute method modification study validates the MicroSEQ® Salmonella spp. Detection Kit [AOAC Performance Tested Method (PTM) 031001] linked with the Pathatrix® 10-Pooling Salmonella spp. Kit (AOAC PTM 090203C) in diced tomatoes, chocolate, and deli ham. The Pathatrix 10-Pooling protocol represents a method modification of the enrichment portion of the MicroSEQ Salmonella spp. The results of the method modification were compared to standard cultural reference methods for diced tomatoes, chocolate, and deli ham. All three matrixes were analyzed in a paired study design. An additional set of chocolate test portions was analyzed using an alternative enrichment medium in an unpaired study design. For all matrixes tested, there were no statistically significant differences in the number of positive test portions detected by the modified candidate method compared to the appropriate reference method. The MicroSEQ Salmonella spp. protocol linked with the Pathatrix individual or 10-Pooling procedure demonstrated reliability as a rapid, simplified, method for the preparation of samples and subsequent detection of Salmonella in diced tomatoes, chocolate, and deli ham.

  8. A test protocol for assessing the hearing status of students with special needs.

    PubMed

    Chen, Hsiao-Chuan; Wang, Nan-Mai; Chiu, Wen-Chen; Liu, Shu-Yu; Chang, Yi-Ping; Lin, Pei-Yu; Chung, King

    2014-10-01

    Individuals with disabilities are often reported to have a high prevalence of undetected hearing disorders/loss, but there is no standardized hearing test protocol for this population. The purposes of this study were (1) to examine the hearing status of students with special needs in Taiwan, and (2) to investigate the use of an on-site hearing test protocol that would adequately detect hearing problems in this population and reduce unnecessary referrals for off-site follow-up services. A total of 238 students enrolled in two schools for special education and one habilitation center participated in the study. Most students had intellectual disabilities and some also had additional syndromes or disorders. A hearing screening protocol including otoscopy, tympanometry, and distortion product otoacoustic emissions was administered to examine students' outer, middle, and inner ear functions, respectively. Pure tone tests were then administered as an on-site follow-up for those who failed or could not be tested using the screening protocol. Only 32.4% of students passed. When administered alone, the referral rate of otoscopy, tympanometry, and otoacoustic emissions were 38.7%, 46.0%, and 48.5%, respectively. The integration of these subtests revealed 52.1% of students needed follow-up services, 11.8% could not be tested, 2.5% had documented hearing loss, and 1.3% needed to be monitored because of negative middle ear pressure. The inclusion of pure tone audiometry increased the passing rate by 9.9% and provided information on hearing sensitivity for an additional 8.6% of students. Hearing assessments and regular hearing screening should be provided as an integral part of health care services for individuals with special needs because of high occurrences of excessive cerumen, middle ear dysfunction, and sensorineural hearing loss. The training of care-givers and teachers of students with special needs is encouraged so that they can help identify hearing problems and reduce the negative impact of hearing disorders and hearing loss. The screening protocol needs to include subtests that examine the status of different parts of their auditory system. The addition of pure tone audiometry as an on-site follow-up tool reduced the rate of off-site referrals and provided more information on hearing sensitivity. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  9. Evaluating Material Flammability in Microgravity and Martian Gravity Compared to the NASA Standard Normal Gravity Test

    NASA Technical Reports Server (NTRS)

    Oslon, Sandra. L.; Ferkul, Paul

    2012-01-01

    Drop tower tests are conducted at Martian gravity to determine the flammability of three materials compared to previous tests in other normal gravity and reduced gravity environments. The comparison is made with consideration of a modified NASA standard test protocol. Material flammability limits in the different gravity and flow environments are tabulated to determine the factor of safety associated with normal gravity flammability screening. Previous testing at microgravity and Lunar gravity indicated that some materials burned to lower oxygen concentrations in low gravity than in normal gravity, although the low g extinction limit criteria are not the same as 1g due to time constraints in drop testing. Similarly, the data presented in this paper for Martian gravity suggest that there is a gravity level below Earth s at which materials burn more readily than on Earth. If proven for more materials, this may indicate the need to include a factor of safety on 1g flammability limits.

  10. A Survey of Attitudes and Practices Regarding the Use of Steroid Supplementation in Pediatric Sepsis.

    PubMed

    Carmean, Amanda; Fortenberry, James D; McCracken, Courtney; Hebbar, Kiran B

    2015-10-01

    Although corticosteroid (CS) supplementation for pediatric septic shock (PSS) is recommended by American College of Critical Care Medicine sepsis guidelines, most data are based on adult trials. Standardized protocols for stimulation testing for adrenal insufficiency (AI) and CS treatment in children have been reported, but the current state of CS use and protocols have not been evaluated in pediatric intensive care units in the United States. We surveyed a group of pediatric intensivists to assess current approaches. An electronic survey with 54 questions on attitudes and current use of CSs was distributed to 49 pediatric critical care and 49 pediatric endocrinology fellowship program directors. Twenty-one (43%) of 49 critical care recipients completed the survey. Eleven (52%) were from medical/surgical units and 10 (48%) were from medical/surgical/cardiac units, with a median of 24 beds and 1614 annual admissions. Thirteen (62%) of 21 recipients rated the importance of steroids in the management of PSS as greater than 4 or 5, with 1 being of no importance and 5 of critical importance. Nineteen (90%) of 21 recipients thought AI occurs "sometimes" or "often" in septic shock. Adrenocorticotropin stimulation testing was frequently used (19 of 21; 90%) but not in protocol. Eighteen (85%) of 21 recipients agreed that "some should" receive "steroids as it improves outcome" and 9% agreed that "most should…" Fourteen (66%) of 21 recipients reported that more than 50% of patients with vasopressor-refractory PSS receive CSs. Hydrocortisone was used in 21 (100%) of 21 recipients, but dosing and duration were variable. Concerns to limit/avoid CSs included hyperglycemia (38%), superinfections (81%), and critical illness myopathy (57%). Only 3 (14%) of 21 recipients reported that they used a CS protocol for PSS. Sixteen (76%) of 21 recipients were not comfortable drawing conclusions from adult studies for PSS. Nineteen (90%) of 21 recipients agreed that it would be important to perform a randomized trial for CS use in PSS. Corticosteroids are used at most centers for treatment of PSS, but significant variation in attitudes and use exists. Most centers identify AI as frequent; most report variable use of stimulation testing and dosing of CSs. Few centers currently use a standard protocol for diagnosis and treatment. Interest in performing a randomized trial for CSs remains because in part of reluctance to accept adult trial data.

  11. Does the Concept of the "Flipped Classroom" Extend to the Emergency Medicine Clinical Clerkship?

    PubMed

    Heitz, Corey; Prusakowski, Melanie; Willis, George; Franck, Christopher

    2015-11-01

    Linking educational objectives and clinical learning during clerkships can be difficult. Clinical shifts during emergency medicine (EM) clerkships provide a wide variety of experiences, some of which may not be relevant to recommended educational objectives. Students can be directed to standardize their clinical experiences, and this improves performance on examinations. We hypothesized that applying a "flipped classroom" model to the clinical clerkship would improve performance on multiple-choice testing when compared to standard learning. Students at two institutions were randomized to complete two of four selected EM clerkship topics in a "flipped fashion," and two others in a standard fashion. For flipped topics, students were directed to complete chief complaint-based asynchronous modules prior to a shift, during which they were directed to focus on the chief complaint. For the other two topics, modules were to be performed at the students' discretion, and shifts would not have a theme. At the end of the four-week clerkship, a 40-question multiple-choice examination was administered with 10 questions per topic. We compared performance on flipped topics with those performed in standard fashion. Students were surveyed on perceived effectiveness, ability to follow the protocol, and willingness of preceptors to allow a chief-complaint focus. Sixty-nine students participated; examination scores for 56 were available for analysis. For the primary outcome, no difference was seen between the flipped method and standard (p=0.494.) A mixed model approach showed no effect of flipped status, protocol adherence, or site of rotation on the primary outcome of exam scores. Students rated the concept of the flipped clerkship highly (3.48/5). Almost one third (31.1%) of students stated that they were unable to adhere to the protocol. Preparation for a clinical shift with pre-assigned, web-based learning modules followed by an attempt at chief-complaint-focused learning during a shift did not result in improvements in performance on a multiple-choice assessment of knowledge; however, one third of participants did not adhere strictly to the protocol. Future investigations should ensure performance of pre-assigned learning as well as clinical experiences, and consider alternate measures of knowledge.

  12. Evaluation of a new very low dose imaging protocol: feasibility and impact on X-ray dose levels in electrophysiology procedures

    PubMed Central

    Bourier, Felix; Reents, Tilko; Ammar-Busch, Sonia; Buiatti, Alessandra; Kottmaier, Marc; Semmler, Verena; Telishevska, Marta; Brkic, Amir; Grebmer, Christian; Lennerz, Carsten; Kolb, Christof; Hessling, Gabriele; Deisenhofer, Isabel

    2016-01-01

    Aims This study presents and evaluates the impact of a new lowest-dose fluoroscopy protocol (Siemens AG), especially designed for electrophysiology (EP) procedures, on X-ray dose levels. Methods and results From October 2014 to March 2015, 140 patients underwent an EP study on an Artis zee angiography system. The standard low-dose protocol was operated at 23 nGy (fluoroscopy) and at 120 nGy (cine-loop), the new lowest-dose protocol was operated at 8 nGy (fluoroscopy) and at 36 nGy (cine-loop). Procedural data, X-ray times, and doses were analysed in 100 complex left atrial and in 40 standard EP procedures. The resulting dose–area products were 877.9 ± 624.7 µGym² (n = 50 complex procedures, standard low dose), 199 ± 159.6 µGym² (n = 50 complex procedures, lowest dose), 387.7 ± 36.0 µGym² (n = 20 standard procedures, standard low dose), and 90.7 ± 62.3 µGym² (n = 20 standard procedures, lowest dose), P < 0.01. In the low-dose and lowest-dose groups, procedure times were 132.6 ± 35.7 vs. 126.7 ± 34.7 min (P = 0.40, complex procedures) and 72.3 ± 20.9 vs. 85.2 ± 44.1 min (P = 0.24, standard procedures), radiofrequency (RF) times were 53.8 ± 26.1 vs. 50.4 ± 29.4 min (P = 0.54, complex procedures) and 10.1 ± 9.9 vs. 12.2 ± 14.7 min (P = 0.60, standard procedures). One complication occurred in the standard low-dose and lowest-dose groups (P = 1.0). Conclusion The new lowest-dose imaging protocol reduces X-ray dose levels by 77% compared with the currently available standard low-dose protocol. From an operator standpoint, lowest X-ray dose levels create a different, reduced image quality. The new image quality did not significantly affect procedure or RF times and did not result in higher complication rates. Regarding radiological protection, operating at lowest-dose settings should become standard in EP procedures. PMID:26589627

  13. Secure quantum communication using classical correlated channel

    NASA Astrophysics Data System (ADS)

    Costa, D.; de Almeida, N. G.; Villas-Boas, C. J.

    2016-10-01

    We propose a secure protocol to send quantum information from one part to another without a quantum channel. In our protocol, which resembles quantum teleportation, a sender (Alice) and a receiver (Bob) share classical correlated states instead of EPR ones, with Alice performing measurements in two different bases and then communicating her results to Bob through a classical channel. Our secure quantum communication protocol requires the same amount of classical bits as the standard quantum teleportation protocol. In our scheme, as in the usual quantum teleportation protocol, once the classical channel is established in a secure way, a spy (Eve) will never be able to recover the information of the unknown quantum state, even if she is aware of Alice's measurement results. Security, advantages, and limitations of our protocol are discussed and compared with the standard quantum teleportation protocol.

  14. Comparison of V-4 and V-5 Exercise/Oxygen Prebreathe Protocols to Support Extravehicular Activity in Microgravity

    NASA Technical Reports Server (NTRS)

    Pollock, N. W.; Natoli, M. J.; Vann, R. D.; Gernhardt, M. L.; Conkin, Johnny

    2007-01-01

    The Prebreathe Reduction Program (PRP) used exercise during oxygen prebreathe to reduce necessary prebreathe time prior to depressurizing to work in a 4.3 psi suit during extravehicular activity (EVA). Initial testing produced a two-hour protocol incorporating ergometry exercise and a 30 min cycle of depress/repress to 10.2 psi where subjects breathed 26.5% oxygen/balance nitrogen (Phase II - 10 min at 75% peak oxygen consumption [VO2 peak] followed by 40 min intermittent light exercise [ILE] [approx. 5.8 mL-per kilogram- per minute], then 50 min of rest). The Phase II protocol (0/45 DCS) was approved for operations and has been used on 40 EVAs, providing significant time savings compared to the standard 4 h resting oxygen prebreathe. The Phase V effort focused on performing all light in-suit exercise. Two oxygen prebreathe protocols were tested sequentially: V-4) 160 min prebreathe with 150 min of continuous ILE. The entire protocol was completed at 14.7 psi. All exercise involved upper body effort. Exercise continued until decompression. V-5) 160 min prebreathe with 140 min of ILE - first 40 min at 14.7 psi, then 30 min at 10.2 psi (breathing 26.5% oxygen) after a 20 min depress, simulating a suit donning period. Subjects were then repressed to 14.7 psi and performed another 50 min of lower body ILE, followed by 50 min rest before decompression. The V-4 protocol was rejected with 3 DCS/6 person-exposures. Initial V-5 testing has produced 0 DCS/11 person-exposures (ongoing trials). The difference in DCS rate was significant (Fisher Exact p=0.029). The observations of DCS were significantly lower in early V-5 trials than in V-4 trials. Additional studies are required to evaluate the relative contribution of the variables in exercise distribution, the 10.2 psi depress/repress component, pre-decompression rest, or possible variation in total oxygen consumption.

  15. Nodule Classification on Low-Dose Unenhanced CT and Standard-Dose Enhanced CT: Inter-Protocol Agreement and Analysis of Interchangeability.

    PubMed

    Lee, Kyung Hee; Lee, Kyung Won; Park, Ji Hoon; Han, Kyunghwa; Kim, Jihang; Lee, Sang Min; Park, Chang Min

    2018-01-01

    To measure inter-protocol agreement and analyze interchangeability on nodule classification between low-dose unenhanced CT and standard-dose enhanced CT. From nodule libraries containing both low-dose unenhanced and standard-dose enhanced CT, 80 solid and 80 subsolid (40 part-solid, 40 non-solid) nodules of 135 patients were selected. Five thoracic radiologists categorized each nodule into solid, part-solid or non-solid. Inter-protocol agreement between low-dose unenhanced and standard-dose enhanced images was measured by pooling κ values for classification into two (solid, subsolid) and three (solid, part-solid, non-solid) categories. Interchangeability between low-dose unenhanced and standard-dose enhanced CT for the classification into two categories was assessed using a pre-defined equivalence limit of 8 percent. Inter-protocol agreement for the classification into two categories {κ, 0.96 (95% confidence interval [CI], 0.94-0.98)} and that into three categories (κ, 0.88 [95% CI, 0.85-0.92]) was considerably high. The probability of agreement between readers with standard-dose enhanced CT was 95.6% (95% CI, 94.5-96.6%), and that between low-dose unenhanced and standard-dose enhanced CT was 95.4% (95% CI, 94.7-96.0%). The difference between the two proportions was 0.25% (95% CI, -0.85-1.5%), wherein the upper bound CI was markedly below 8 percent. Inter-protocol agreement for nodule classification was considerably high. Low-dose unenhanced CT can be used interchangeably with standard-dose enhanced CT for nodule classification.

  16. SPIRIT 2013 Statement: defining standard protocol items for clinical trials.

    PubMed

    Chan, An-Wen; Tetzlaff, Jennifer M; Altman, Douglas G; Laupacis, Andreas; Gøtzsche, Peter C; Krle A-Jerić, Karmela; Hrobjartsson, Asbjørn; Mann, Howard; Dickersin, Kay; Berlin, Jesse A; Dore, Caroline J; Parulekar, Wendy R; Summerskill, William S M; Groves, Trish; Schulz, Kenneth F; Sox, Harold C; Rockhold, Frank W; Rennie, Drummond; Moher, David

    2015-12-01

    The protocol of a clinical trial serves as the foundation for study planning, conduct, reporting, and appraisal. However, trial protocols and existing protocol guidelines vary greatly in content and quality. This article describes the systematic development and scope of SPIRIT (Standard Protocol Items: Recommendations for Interventional Trials) 2013, a guideline for the minimum content of a clinical trial protocol. The 33-item SPIRIT checklist applies to protocols for all clinical trials and focuses on content rather than format. The checklist recommends a full description of what is planned; it does not prescribe how to design or conduct a trial. By providing guidance for key content, the SPIRIT recommendations aim to facilitate the drafting of high-quality protocols. Adherence to SPIRIT would also enhance the transparency and completeness of trial protocols for the benefit of investigators, trial participants, patients, sponsors, funders, research ethics committees or institutional review boards, peer reviewers, journals, trial registries, policymakers, regulators, and other key stakeholders.

  17. SPIRIT 2013 Statement: Defining Standard Protocol Items for Clinical Trials

    PubMed Central

    Chan, An-Wen; Tetzlaff, Jennifer M.; Altman, Douglas G.; Laupacis, Andreas; Gøtzsche, Peter C.; Krleža-Jerić, Karmela; Hróbjartsson, Asbjørn; Mann, Howard; Dickersin, Kay; Berlin, Jesse A.; Doré, Caroline J.; Parulekar, Wendy R.; Summerskill, William S.M.; Groves, Trish; Schulz, Kenneth F.; Sox, Harold C.; Rockhold, Frank W.; Rennie, Drummond; Moher, David

    2016-01-01

    The protocol of a clinical trial serves as the foundation for study planning, conduct, reporting, and appraisal. However, trial protocols and existing protocol guidelines vary greatly in content and quality. This article describes the systematic development and scope of SPIRIT (Standard Protocol Items: Recommendations for Interventional Trials) 2013, a guideline for the minimum content of a clinical trial protocol. The 33-item SPIRIT checklist applies to protocols for all clinical trials and focuses on content rather than format. The checklist recommends a full description of what is planned; it does not prescribe how to design or conduct a trial. By providing guidance for key content, the SPIRIT recommendations aim to facilitate the drafting of high-quality protocols. Adherence to SPIRIT would also enhance the transparency and completeness of trial protocols for the benefit of investigators, trial participants, patients, sponsors, funders, research ethics committees or institutional review boards, peer reviewers, journals, trial registries, policymakers, regulators, and other key stakeholders. PMID:23295957

  18. SPIRIT 2013 statement: defining standard protocol items for clinical trials.

    PubMed

    Chan, An-Wen; Tetzlaff, Jennifer M; Altman, Douglas G; Laupacis, Andreas; Gøtzsche, Peter C; Krleža-Jerić, Karmela; Hróbjartsson, Asbjørn; Mann, Howard; Dickersin, Kay; Berlin, Jesse A; Doré, Caroline J; Parulekar, Wendy R; Summerskill, William S M; Groves, Trish; Schulz, Kenneth F; Sox, Harold C; Rockhold, Frank W; Rennie, Drummond; Moher, David

    2013-02-05

    The protocol of a clinical trial serves as the foundation for study planning, conduct, reporting, and appraisal. However, trial protocols and existing protocol guidelines vary greatly in content and quality. This article describes the systematic development and scope of SPIRIT (Standard Protocol Items: Recommendations for Interventional Trials) 2013, a guideline for the minimum content of a clinical trial protocol.The 33-item SPIRIT checklist applies to protocols for all clinical trials and focuses on content rather than format. The checklist recommends a full description of what is planned; it does not prescribe how to design or conduct a trial. By providing guidance for key content, the SPIRIT recommendations aim to facilitate the drafting of high-quality protocols. Adherence to SPIRIT would also enhance the transparency and completeness of trial protocols for the benefit of investigators, trial participants, patients, sponsors, funders, research ethics committees or institutional review boards, peer reviewers, journals, trial registries, policymakers, regulators, and other key stakeholders.

  19. IMPLEMENTATION AND VALIDATION OF STATISTICAL TESTS IN RESEARCH'S SOFTWARE HELPING DATA COLLECTION AND PROTOCOLS ANALYSIS IN SURGERY.

    PubMed

    Kuretzki, Carlos Henrique; Campos, Antônio Carlos Ligocki; Malafaia, Osvaldo; Soares, Sandramara Scandelari Kusano de Paula; Tenório, Sérgio Bernardo; Timi, Jorge Rufino Ribas

    2016-03-01

    The use of information technology is often applied in healthcare. With regard to scientific research, the SINPE(c) - Integrated Electronic Protocols was created as a tool to support researchers, offering clinical data standardization. By the time, SINPE(c) lacked statistical tests obtained by automatic analysis. Add to SINPE(c) features for automatic realization of the main statistical methods used in medicine . The study was divided into four topics: check the interest of users towards the implementation of the tests; search the frequency of their use in health care; carry out the implementation; and validate the results with researchers and their protocols. It was applied in a group of users of this software in their thesis in the strict sensu master and doctorate degrees in one postgraduate program in surgery. To assess the reliability of the statistics was compared the data obtained both automatically by SINPE(c) as manually held by a professional in statistics with experience with this type of study. There was concern for the use of automatic statistical tests, with good acceptance. The chi-square, Mann-Whitney, Fisher and t-Student were considered as tests frequently used by participants in medical studies. These methods have been implemented and thereafter approved as expected. The incorporation of the automatic SINPE (c) Statistical Analysis was shown to be reliable and equal to the manually done, validating its use as a research tool for medical research.

  20. Metallic artifacts from internal scaphoid fracture fixation screws: comparison between C-arm flat-panel, cone-beam, and multidetector computed tomography.

    PubMed

    Finkenstaedt, Tim; Morsbach, Fabian; Calcagni, Maurizio; Vich, Magdalena; Pfirrmann, Christian W A; Alkadhi, Hatem; Runge, Val M; Andreisek, Gustav; Guggenberger, Roman

    2014-08-01

    The aim of this study was to compare image quality and extent of artifacts from scaphoid fracture fixation screws using different computed tomography (CT) modalities and radiation dose protocols. Imaging of 6 cadaveric wrists with artificial scaphoid fractures and different fixation screws was performed in 2 screw positions (45° and 90° orientation in relation to the x/y-axis) using multidetector CT (MDCT) and 2 flat-panel CT modalities, C-arm flat-panel CT (FPCT) and cone-beam CT (CBCT), the latter 2 with low and standard radiation dose protocols. Mean cartilage attenuation and metal artifact-induced absolute Hounsfield unit changes (= artifact extent) were measured. Two independent radiologists evaluated different image quality criteria using a 5-point Likert-scale. Interreader agreements (Cohen κ) were calculated. Mean absolute Hounsfield unit changes and quality ratings were compared using Friedman and Wilcoxon signed-rank tests. Artifact extent was significantly smaller for MDCT and standard-dose FPCT compared with CBCT low- and standard-dose acquisitions (all P < 0.05). No significant differences in artifact extent among different screw types and scanning positions were noted (P > 0.05). Both MDCT and FPCT standard-dose protocols showed equal ratings for screw bone interface, fracture line, and trabecular bone evaluation (P = 0.06, 0.2, and 0.2, respectively) and performed significantly better than FPCT low- and CBCT low- and standard-dose acquisitions (all P < 0.05). Good interreader agreement was found for image quality comparisons (Cohen κ = 0.76-0.78). Both MDCT and FPCT standard-dose acquisition showed comparatively less metal-induced artifacts and better overall image quality compared with FPCT low-dose and both CBCT acquisitions. Flat-panel CT may provide sufficient image quality to serve as a versatile CT alternative for postoperative imaging of internally fixated wrist fractures.

Top