Sample records for stapes surgery

  1. Lasers in stapes surgery: a review.

    PubMed

    Young, E; Mitchell-Innes, A; Jindal, M

    2015-07-01

    Lasers in stapes surgery are used to divide the anterior and posterior crus of the stapes, divide the stapedius tendon and perforate the footplate. The ideal laser should not penetrate deeply into the perilymph (thereby increasing its temperature). It should be conducted through optical fibres, allowing easy manipulation, and should have good water absorption, equating to high bone ablation efficiency. This review discusses the various different lasers used in stapes surgery with regard to their properties and suitability for this type of surgery. In particular, the laser parameters used are discussed to facilitate their clinical use.

  2. The quartile benefit plot: a middle ear surgery benefit assessment scheme.

    PubMed

    Schmerber, Sébastien; Karkas, Alexandre; Righini, Christian A; Chahine, Karim A

    2008-05-01

    The purpose of this study is to present a new method for the assessment of hearing improvement following stapes surgery, taking into account additional, previously omitted evaluation criteria. Retrospective. A quartile plot, based on the currently used Glasgow benefit plot, is structured to include two additional criteria of hearing assessment, namely the absence of postoperative sensorineural hearing loss and the closure of the air-bone gap to <10 dB. Pre- and postoperative hearing results of 132 patients diagnosed with bilateral otosclerosis and treated with bilateral stapes surgery were plotted on both the classical Glasgow benefit plot and the new quartile benefit plot. The difference in success assessment due to stricter assessment criteria is demonstrated. Functional success rate following bilateral stapes surgery as plotted on the traditional Glasgow benefit plot was 51.5%. Success rate for bilateral stapes surgery assessed on the new quartile plot with the addition of the two new criteria was 38.64%. The difference in success rates was found to be statistically significant. The basis of benefit assessment in stapes surgery solely on the mean deficit in air conduction results in overestimation of success rate. This study demonstrates that results that appear satisfactory when judged by the Glasgow benefit plot are of modest success when assessed by the new quartile plot. The quartile benefit plot presented in this paper provides a strict measure of presentation and evaluation of stapes surgery results.

  3. Changes to Hearing Levels Over the First Year After Stapes Surgery: An Analysis of 139 Patients.

    PubMed

    Nash, Robert; Patel, Bhavesh; Lavy, Jeremy

    2018-06-15

    Stapes surgery is performed for hearing restoration in patients with otosclerosis. Results from stapes surgery are good, although a small proportion will have a persistent conductive hearing loss and will consider revision surgery. The timing of such surgery depends on expected changes to hearing thresholds during the postoperative period. We performed a retrospective case series analysis of a database of outcomes from stapes surgery performed between July 26, 2013 and March 11, 2016 at one center. Hearing outcomes over the year subsequent to surgery were recorded. There was a significant improvement in hearing outcomes between the postoperative visit at 6 weeks (mean air-bone gap 6.0 dB) and the hearing outcome at 6 months (mean air-bone gap 3.3 dB) (p < 0.01). This improvement was maintained at 12 months (mean air-bone gap 3.1 dB), although there were individual patients whose hearing outcome improved or deteriorated during this period. Improvements in air conduction thresholds mirrored improvements in air-bone gap measurements. Patients with an initial suboptimal or poor result after stapes surgery may observed improvement in their hearing thresholds in the year after surgery. These patients may have large preoperative air-bone gaps, and have a trend to have obliterated footplates. Revision surgery should not be considered until at least 6 months after primary surgery.

  4. Outcome measures in stapes surgery: postoperative results are independent from preoperative parameters.

    PubMed

    Koopmann, Mario; Weiss, Daniel; Savvas, Eleftherios; Rudack, Claudia; Stenner, Markus

    2015-09-01

    The aim of this study was to compare audiometric results before and after stapes surgery and identify potential prognostic factors to appropriately select patients with otosclerosis who will most likely benefit from surgery. We enrolled 126 patients with otosclerosis (162 consecutive ears) in our study who underwent stapes surgery between 2007 and 2012 at our institution. Preoperative and postoperative data including pure-tone audiometry, speech audiometry, stapedial reflex audiometry and surgical data were analyzed. The average preoperative air-bone gap (ABG) was 28.9 ± 8.6 dB. Male patients and patients older than 45 years of age had greater preoperative ABGs in comparison to females and younger patients. Postoperative ABGs were 11.2 ± 7.4 dB. The average ABG gain was 17.7 ± 11.1 dB. Preoperative audiometric data, age, gender and type of surgery did not influence the postoperative results. Stapes surgery offers predictable results independent from disease progression or patient-related factors. While absolute values of hearing improvement are instrumental in reflecting audiometric results of a cohort, relative values better reflect individual's audiometric data resembling the patient's benefit.

  5. Teflon-wire piston or stainless-steel bucket stapes prosthesis: does it make a difference?

    PubMed

    Farrior, J B; Temple, A E

    1999-04-01

    The goal of this study was to determine whether postoperative (implantation of a stapes prosthesis) hearing gain and the amount of air-bone gap overclosure are more improved with the Teflon-wire piston or with the stainless-steel bucket prosthesis. We retrospectively reviewed the outcomes of 82 surgeries that had been performed by the primary author; 41 of these patients had received a Fisch Teflon-wire piston, and 41 had received a Bailey-modified Robinson stainless-steel bucket prosthesis. The mean hearing gain for the patients who received the Teflon-wire piston was 23.3 dB after primary stapes surgery and 20.5 dB after revision surgery. Patients who received the stainless-steel bucket prosthesis experienced a mean hearing gain of 20.7 and 20.3 dB, respectively. Following primary stapes surgery, the air-bone gap overclosure was 4.4 dB with the Teflon-wire piston and 5.2 dB with the stainless-steel bucket prosthesis. There was no statistically significant difference in either hearing gain or air-bone gap overclosure between the two prostheses.

  6. Active middle ear implant coupled bilaterally to the round window despite bilateral implanted stapes prostheses.

    PubMed

    Coordes, Annekatrin; Jahreiss, Linda; Schönfeld, Uwe; Lenarz, Minoo

    2017-02-01

    After stapes surgery, patients with mixed or moderate hearing loss have limited possibilities for hearing improvement. We are reporting on a patient who underwent stapedotomy bilaterally 20 years ago and had sensorineural and mixed hearing loss. Recurrent otitis externa prevented the use of hearing aids. This patient was treated bilaterally with the Vibrant Soundbridge (Med-El, Innsbruck, Austria) successively. The Schuknecht piston stapes prostheses remained in situ. The Floating Mass Transducer (FMT; Med-El) was coupled to the round window (RW) and provided good acoustic reinforcement bilaterally. In conclusion, for patients with otosclerosis and stapes surgery, the FMT-RW coupling (Bess AG, Berlin, DE) is a safe procedure with good acoustic amplification. Laryngoscope, 2016 127:500-503, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  7. Short-Term Audiological Results of Diode Laser in Comparison with Manual Perforation in Stapes Surgery

    PubMed Central

    Hamerschmidt, Rogerio; Saab, Stephanie Sbizera; Carvalho, Bettina; Carmo, Carolina do

    2018-01-01

    Introduction  Diode laser is a new alternative in stapes surgery for otosclerosis. The present study is the first to compare the short-term results of the surgery performed using diode laser to those obtained through the conventional fenestration technique. Objective  To use audiometry to establish a comparative analysis between the functional results obtained through surgery for otosclerosis using diode laser and the conventional technique. Method  Audiometric evaluation of 12 patients submitted to stapes surgery for otosclerosis, using diode laser or conventional fenestration by needle and drills, between 2014 and 2015. Each group was composed of 6 patients. Pre and post-operative measures were compared for three months in both groups. The speech recognition threshold, the air and bone conduction threshold, as well as the gap between them at 500 Hz, 1 KHz, 2 KHz and 4 KHz were measured. Results  Significant difference in bone conduction and SRT was observed when compared post- and preoperative results in the diode group. However diode and conventional technique groups presented significant differences in air conduction and air-bone gap, suggesting that both can provide functional improvement. Conclusion  Laser stapedotomy is a safe technique with good results. Both laser surgery and the conventional technique have improved the hearing of patients with a discreet advantage for the diode laser. Further prospective and randomized clinical trials are required to disclose all possible benefits of the stapes surgery using diode laser. PMID:29619098

  8. Short-Term Audiological Results of Diode Laser in Comparison with Manual Perforation in Stapes Surgery.

    PubMed

    Hamerschmidt, Rogerio; Saab, Stephanie Sbizera; Carvalho, Bettina; Carmo, Carolina do

    2018-04-01

    Introduction  Diode laser is a new alternative in stapes surgery for otosclerosis. The present study is the first to compare the short-term results of the surgery performed using diode laser to those obtained through the conventional fenestration technique. Objective  To use audiometry to establish a comparative analysis between the functional results obtained through surgery for otosclerosis using diode laser and the conventional technique. Method  Audiometric evaluation of 12 patients submitted to stapes surgery for otosclerosis, using diode laser or conventional fenestration by needle and drills, between 2014 and 2015. Each group was composed of 6 patients. Pre and post-operative measures were compared for three months in both groups. The speech recognition threshold, the air and bone conduction threshold, as well as the gap between them at 500 Hz, 1 KHz, 2 KHz and 4 KHz were measured. Results  Significant difference in bone conduction and SRT was observed when compared post- and preoperative results in the diode group. However diode and conventional technique groups presented significant differences in air conduction and air-bone gap, suggesting that both can provide functional improvement. Conclusion  Laser stapedotomy is a safe technique with good results. Both laser surgery and the conventional technique have improved the hearing of patients with a discreet advantage for the diode laser. Further prospective and randomized clinical trials are required to disclose all possible benefits of the stapes surgery using diode laser.

  9. Stapes surgery in residency: the UFPR clinical hospital experience.

    PubMed

    Caldart, Adriano Ulisses; Terruel, Igor; Enge, Dair Jocely; Kurogi, Adriana Sayuri; Buschle, Maurício; Mocellin, Marcos

    2007-01-01

    Surgery of the stapedius remains the established treatment for otosclerosis. Recent publications have showed that success in surgeries done by residents have decreased and hearing results are worse than those obtained by experienced otologic surgeons. To evaluate the experience of the otorhinolaryngology unit, Parana University, relative to stapes surgery done in the residency training program. A retrospective study of 114 stapes surgeries done in the past 9 years in 96 patients. Audiometric results were analysed according to the Committee on Hearing and Equilibrium guidelines and the Amsterdam Hearing Evaluation Plots. The improvement of the airway postoperative gap and thresholds were taken into account. 96 patients were included, most of them female adults (67.7%) and white (93.7%). Stapedectomy was done in 50.9% of cases, mostly under local anesthesia and sedation (96.5%), using mostly the Teflon prosthesis (37.7%). The surgical success rate was 50.88%, there was an 11.4% complication rate. Postoperative hearing gains considered as surgical success were inferior to published results in the literature, done by experienced surgeons.

  10. Modifications to a 3D-printed temporal bone model for augmented stapes fixation surgery teaching.

    PubMed

    Nguyen, Yann; Mamelle, Elisabeth; De Seta, Daniele; Sterkers, Olivier; Bernardeschi, Daniele; Torres, Renato

    2017-07-01

    Functional outcomes and complications in otosclerosis surgery are governed by the surgeon's experience. Thus, teaching the procedure to residents to guide them through the learning process as quickly as possible is challenging. Artificial 3D-printed temporal bones are replacing cadaver specimens in many institutions to learn mastoidectomy, but these are not suitable for middle ear surgery training. The goal of this work was to adapt such an artificial temporal bone to aid the teaching of otosclerosis surgery and to evaluate this tool. We have modified a commercially available 3D-printed temporal bone by replacing the incus and stapes of the model with in-house 3D-printed ossicles. The incus could be attached to a 6-axis force sensor. The stapes footplate was fenestrated and attached to a 1-axis force sensor. Six junior surgeons (residents) and seven senior surgeons (fellows or consultants) were enrolled to perform piston prosthesis placement and crimping as performed during otosclerosis surgery. The time required to perform the tasks and the forces applied to the incus and stapes were collected and analyzed. No statistically significant differences were observed between the junior and senior groups for time taken to perform the tasks and the forces applied to the incus during crimping and placement of the prosthesis. However, significantly lower forces were applied to the stapes by the senior surgeons in comparison with the junior surgeons during prosthesis placement (junior vs senior group, 328 ± 202.9 vs 80 ± 99.6 mN, p = 0.008) and during prosthesis crimping (junior vs senior group, 565 ± 233 vs 66 ± 48.6 mN, p = 0.02). We have described a new teaching tool for otosclerosis surgery based on the modification of a 3D-printed temporal bone to implement force sensors on the incus and stapes. This tool could be used as a training tool to help the residents to self-evaluate their progress with recording of objective measurements.

  11. Comparative electron microscopic study of the surface structure of gold, Teflon, and titanium stapes prostheses.

    PubMed

    Kwok, P; Fisch, U; Strutz, J; Jacob, P

    2001-09-01

    The goal of this study was to compare stapes prostheses of different materials with respect to their surface structures and to discuss their suitability for their use in stapes surgery. The surface condition of a stapes prosthesis plays an important role in relation to the type of membrane that forms between the stapes piston and the bony edge of the stapedotomy opening. The quality of this membrane in thickness and mobility is one of the determinants for postoperative hearing improvement. The surface conditions of gold, Teflon/steel, Teflon/platinum, and titanium stapes prostheses were examined with a scanning electron microscope. The loop, shaft, and end of each prosthesis were studied. The gold piston was the smoothest of the four pistons examined. When it was cut with a scalpel, a very smooth surface was achieved at the end area. The Teflon piston had the roughest surface. However, when it was cut, a smooth surface with a parallel arrangement of fibers resulted. Its steel loop was the smoothest, followed by gold and platinum. The titanium shaft had a scaly surface, which remained when the end of the shaft was shortened. Because a certain roughness of the piston surface is necessary for the development of a stable membrane between the piston and the edge of the stapedotomy opening, the titanium prosthesis is considered to be the most suitable for stapes surgery of the three pistons examined.

  12. Thirty years of stapes surgery.

    PubMed

    Shea, J J

    1988-01-01

    The modern stapedectomy with prosthesis insertion and living oval window seal, like the modern cataract extraction with lens replacement, is now performed, very much the same, throughout the world. I have reviewed the evolution of stapes surgery during these last thirty years and tried to gain some agreement for several important facts about otosclerosis and several basic principals of stapes surgery. While a well-performed stapedectomy can eliminate the conductive component, the sensorineural hearing loss continues and, in about one-third, will progress till the patient, after age 65, must return to a hearing aid. A piston prosthesis gives the best hearing results: 0.6 mm diameter, when half the footplate is removed and a living oval window seal interposed, and 0.6 mm diameter when a small opening is made in the footplate obliterated by otosclerosis. I prefer a teflon prosthesis to stainless steel because it can be altered by the surgeon at operation, and vein as an oval window seal. I have presented a rare group of patients who develop facial palsy 5-1/2 days after uncomplicated stapedectomy, of whom all recover quickly and completely. I am confident that progress will continue to be made in the understanding of otosclerosis, and the performance of stapes surgery, but in these last thirty years we have made a good beginning.

  13. Teflon Implants Versus Titanium Implants in Stapes Surgery.

    PubMed

    Bansal, Mohan

    2016-03-01

    Otosclerosis is the most common cause of bilateral gradually progressive conductive hearing loss with normal tympanic membrane and Eustachian tube. Otosclerosis surgical treatment is one of the most gratifying operations in Otorhinolaryngology. It is not only the surgical techniques but also the prosthesis which are evolving in the attempt of providing best hearing results. Teflon piston is the most commonly employed prosthesis in stapes surgery. Titanium pistons are relatively the new development in the evolution of stapes prosthesis. The aim of this review article is to know and compare the surgical technicalities and postoperative outcomes including hearing improvement after the use of Teflon and titanium stapes piston. The adverse reactions occurred during follow-up were taken into consideration. The data in this article are supported by a Medline search. The use of both the prosthesis gave good results in cases of otosclerosis. The placement of titanium soft clip design was found easier than the earlier àWengen design of clip piston.

  14. Immediate postoperative nystagmus and vestibular symptoms after stapes surgery.

    PubMed

    Hirvonen, Timo P; Aalto, Heikki

    2013-08-01

    Vestibular disturbance is frequent, but mild even immediately after stapes surgery. Vestibular symptoms improved or disappeared quickly, and they did not correlate with nystagmus. Outpatient stapes surgery performed under local anaesthesia is a feasible approach. Vestibular symptoms are common and may prevent outpatient surgery. The time course of vestibular disturbance is unclear, and we aimed to evaluate it immediately after the operation in the recovery room. Twenty patients with otosclerosis undergoing stapedotomy were prospectively included in the study. Postoperative symptoms were collected and nystagmus was recorded with video-oculography (VOG) on average 29 min after the surgery. None of the patients had spontaneous nystagmus with gaze fixation. Nine patients (45%) had slow spontaneous horizontal nystagmus (mean slow phase velocity of 1.1°/s) in the primary position without gaze fixation. In seven of these, the nystagmus obeyed Alexander's law. Nine patients (45%) had vestibular symptoms at the end of the surgery, and four patients at the time of VOG recording. Vertigo was experienced immediately after the operation in five, floating sensation in two, and unspecific dizziness in two patients. Vestibular symptoms were mild or moderate in most patients. The occurrence of nystagmus did not correlate with vestibular symptoms (p > 0.05).

  15. Stapedotomy in osteogenesis imperfecta: a prospective study of 32 consecutive cases.

    PubMed

    Vincent, Robert; Wegner, Inge; Stegeman, Inge; Grolman, Wilko

    2014-12-01

    To prospectively evaluate hearing outcomes in patients with osteogenesis imperfecta undergoing primary stapes surgery and to isolate prognostic factors for success. A nonrandomized, open, prospective case series. A tertiary referral center. Twenty-five consecutive patients who underwent 32 primary stapedotomies for osteogenesis imperfecta with evidence of stapes fixation and available postoperative pure-tone audiometry. Primary stapedotomy with vein graft interposition and reconstruction with a regular Teflon piston or bucket handle-type piston. Preoperative and postoperative audiometric evaluation using conventional 4-frequency (0.5, 1, 2, and 4 kHz) audiometry. Air-conduction thresholds, bone-conduction thresholds, and air-bone gap were measured. The overall audiometric results as well as the results of audiometric evaluation at 3 months and at least 1 year after surgery were used. Overall, postoperative air-bone gap closure to within 10 dB was achieved in 88% of cases. Mean (standard deviation) gain in air-conduction threshold was 22 (9.4) dB for the entire case series, and mean (standard deviation) air-bone gap closure was 22 (9.0) dB. Backward multivariate logistic regression showed that a model with preoperative air-bone gap closure and intraoperatively established incus length accurately predicts success after primary stapes surgery. Stapes surgery is a feasible and safe treatment option in patients with osteogenesis imperfecta. Success is associated with preoperative air-bone gap and intraoperatively established incus length.

  16. Electrocoagulation improving bone cement use in middle-ear surgery: short-term and middle-term results.

    PubMed

    Galy-Bernadoy, C; Akkari, M; Mondain, M; Uziel, A; Venail, F

    2016-12-01

    Bone cement is used for ossicular chain repair and revision stapes surgery. Its efficient use requires cautious removal of mucosa from the ossicles. This paper reports a technique for easy, fast and safe removal of this mucosa prior to cement application. It consists of the application of monopolar electrocoagulation on the ossicles prior to bone cement application. The outcomes of six cases of revision stapes surgery and seven cases of partial ossiculoplasty, conducted between 2007 and 2012 using this new technique, were evaluated. Intra-operative reports and audiometric data were collected. During the last assessment, reconstruction using bone cement resulted in mean post-operative air-bone gaps of 4.1 ± 6.5 dB in revision stapes surgery cases and 5.7 ± 5.5 dB in partial ossiculoplasty cases, reflecting a significant hearing improvement (p = 0.03). No complications were observed. Electrocoagulation allows the removal of mucosa from the ossicles in an easy, fast and safe manner, enabling the use of bone cement for ossicular chain reconstruction.

  17. Stapes surgery: how precisely do different prostheses attach to the long process of the incus with different instruments and different surgeons?

    PubMed

    Kwok, Pingling; Fisch, Ugo; Strutz, Jürgen; May, John

    2002-05-01

    The goal of this study was to compare the attachment of stapes prostheses with differently shaped loops to the long process of the incus. In stapes surgery, the attachment of the prosthesis to the long process of the incus plays an important role concerning the gain in hearing and the development of late complications such as incus erosion and necrosis. Band-shaped and spiral loops have been developed to achieve a broad, firm attachment to the long process of the incus. During stapes surgery, the view at the prosthesis is restricted, making it impossible to evaluate the effects of the differently shaped loops. Gold, steel/Teflon, platinum/Teflon, and two different titanium stapes prostheses were inserted in 30 specially prepared temporal bones by three experienced surgeons using the Fisch technique with the McGee and straight alligator forceps for the crimping of the loops. Photographs were taken with 0- and 70-degree rod lens telescopes at defined views. In all prostheses, a sufficiently firm attachment to the long process of the incus was achieved. The attachment of band-shaped loops proved to be better with the straight alligator forceps. The band-shaped loops showed a better contact with the incus than did the wire loops. However, the broad spiral-shaped loops led to a loss of the perpendicular axis of the piston to the long incus process. The geometry of the loop affects the final length of the piston in the vestibule and its angle to the long process of the incus.

  18. Finite element analysis of auditory characteristics in patients with middle ear diseases.

    PubMed

    Tu, Bo; Li, Xiaoping; Nie, Zhenhua; Shi, Changzheng; Li, Hengguo

    2017-07-01

    This study validates that a finite element model of the human ossicular chain and tympanic membrane can be used as an effective surgical assessment tool in clinics. The present study was performed to investigate the application of a finite element model of ossicular chain and tympanic membrane for fabrication of individualized artificial ossicles. Twenty patients (20 ears) who underwent surgery for middle ear disease (n = 20) and 10 healthy controls (10 ears) were enrolled in the hospital. Computed tomography (CT) and pure tone audiometry were performed before and after surgery. A finite element model was developed using CT scans, and correlation analysis was conducted between stapes displacement and surgical methods. An audiometric test was also performed for 14 patients before and after surgery. Stapes displacement in the healthy group (average = 3.31 × 10 -5  mm) was significantly greater than that in the impaired group (average = 1.41 × 10 -6 mm) prior to surgery. After surgery, the average displacement in the impaired group was 2.55 × 10 -6 mm, which represented a significant improvement. For the patients who underwent the audiometric test, 10 improved hearing after surgery, and stapes displacement increased in nine of these 10 patients.

  19. Capturing thermal, mechanical, and acoustic effects of the diode (980 nm) laser in stapedotomy.

    PubMed

    Kamalski, Digna M A; de Boorder, Tjeerd; Bittermann, Arnold J N; Wegner, Inge; Vincent, Robert; Grolman, Wilko

    2014-07-01

    The diode laser, with a wavelength of 980 nm, has promising characteristics for being used for the fenestration during stapedotomy. It is known that at this wavelength absorption in pigmented tissues is high, and absorption in water is relatively low compared with medical lasers in the infrared, making it theoretically an applicable laser for stapes surgery in patients with otosclerosis. Another important advantage is that, with respect to other lasers, this device is relatively inexpensive. Despite the potential advantages, the available literature only shows limited reports of this laser being used in stapes surgery. The present article evaluates the thermal, mechanical, and acoustic properties of the diode laser during stapes surgery. For the mechanical effects, high-speed imaging with a frame rate up to 4000 f/s (=250 μs resolution) was performed in an inner ear model. For thermal effects, the high-speed Schlieren technique was used. Acoustics were recorded by a hydrophone, incorporated in the model. Pulse settings were 100 ms, 3 W, which are the same settings used during stapes surgery. The application of the diode laser resulted in limited mechanical and thermal effects. Impulse noise was low with an average of 52 (SD, 7.8) dB (A). Before carbonization of the tip of the delivery laser, fiber enhances ablation of the footplate. The 980-nm diode laser is a useful tool for laser-assisted stapedotomy in patients with otosclerosis. Mechanical, thermal, and acoustic effects are limited and well within the safety limits.

  20. Femtosecond laser ablation of the stapes

    NASA Astrophysics Data System (ADS)

    McCaughey, Ryan G.; Sun, Hui; Rothholtz, Vanessa S.; Juhasz, Tibor; Wong, Brian J. F.

    2009-03-01

    A femtosecond laser, normally used for LASIK eye surgery, is used to perforate cadaveric human stapes. The thermal side effects of bone ablation are measured with a thermocouple in an inner ear model and are found to be within acceptable limits for inner ear surgery. Stress and acoustic events, recorded with piezoelectric film and a microphone, respectively, are found to be negligible. Optical microscopy, scanning electron microscopy, and optical coherence tomography are used to confirm the precision of the ablation craters and lack of damage to the surrounding tissue. Ablation is compared to that from an Er:YAG laser, the current laser of choice for stapedotomy, and is found to be superior. Ultra-short-pulsed lasers offer a precise and efficient ablation of the stapes, with minimal thermal and negligible mechanical and acoustic damage. They are, therefore, ideal for stapedotomy operations.

  1. Experimental study on heat transmission to the vestibule during CO2 laser use in revision stapes surgery.

    PubMed

    Szymański, M; Morshed, K; Mills, R

    2007-01-01

    We studied the transmission of heat to the vestibule during revision stapes surgery with a piston in situ, using a CO2 laser, in an in vitro model. A type K thermocouple was placed around the medial end of stainless steel and fluoroplastic wire pistons in a 'vestibule' filled with saline. The effect of laser hits on fluoroplastic wire and stainless steel stapes prostheses was investigated. The effect of introducing a vein graft to seal the stapedotomy was also examined. Greater temperature rises occurred with stainless steel than with fluoroplastic wire pistons. The addition of the vein graft reduced heat transmission. Application of the CO2 laser to fluoroplastic wire pistons, using the power settings suggested by the manufacturer, is not likely to damage the inner-ear structures. Application of 6 W laser energy to stainless steel pistons can potentially disturb the inner-ear function.

  2. First experience with the fiber-enabled CO2 laser in stapes surgery and a comparison with the "one-shot" technique.

    PubMed

    Brase, Christoph; Schwitulla, Judith; Künzel, Julian; Meusel, Thomas; Iro, Heinrich; Hornung, Joachim

    2013-12-01

    To compare bone conduction after fiber-enabled CO2 laser perforation of the stapes footplate with conduction after the "one-shot" technique during stapedotomy in patients with otosclerosis. Retrospective clinical study. Tertiary reference center. We evaluated data from 178 patients who had undergone primary stapedotomy for suspected stapedial ankylosis. The stapes footplate was perforated using a fiber-enabled CO2 laser in 89 patients and the "one-shot" technique in the other 89. Only consecutive surgery was considered. Bone conduction thresholds were determined at 0.5, 1, 2, and 4 kHz on the first and third postoperative days in all patients; 172 patients were followed up after 1 month. Audiograms were compared with preoperative bone conduction. The postoperative bone conduction threshold on Day 1 was significantly worse at almost all frequencies. At 0.5 and 2 kHz, it improved within a month and was significantly different from the preoperative value. Bone conduction threshold at 4 kHz showed the greatest deterioration immediately after surgery, improving considerably in 1 month but remaining worse than at baseline. Only at 1 kHz was there no significant immediate hearing loss. Direct comparison of the fiber-enabled CO2 laser and the "one-shot" technique showed no statistically significant differences. Compared with the "one-shot" technique, the fiber-enabled CO2 laser can be used safely in stapes surgery, without great risk to the patient. In our opinion, it has practical advantages, especially in difficult anatomic conditions.

  3. Transmission of heat to the vestibule during revision stapes surgery using a KTP laser: an in vitro study.

    PubMed

    Szymanski, Marcin; Mills, Robert; Abel, Eric

    2003-05-01

    The transmission of heat to the vestibule during revision stapes surgery with a piston in situ has been studied using a KTP laser in an in vitro model. A type K thermocouple was placed around the medial of each piston tested in a 'vestibule' filled with saline. The effect of laser hits on fluoroplastic, fluoroplastic-wire and stainless steel stapes prostheses was investigated. The effect of adding blood to the operative field, of introducing a vein graft to seal the stapedotomy and of vaporizing soft tissue in the oval window were also examined. Greater temperature rises occurred with stainless steel than with the other piston types and smaller rises occurred when there was a vein graft in situ. The maximum temperature rise recorded was 2.6 degrees C. We conclude that the use of the KTP laser to clear soft tissue from the oval window is safe when operated at the power levels recommended by the manufacturer.

  4. Cochlin-tomoprotein (CTP) detection test identified perilymph leakage preoperatively in revision stapes surgery.

    PubMed

    Kataoka, Yuko; Ikezono, Tetsuo; Fukushima, Kunihiro; Yuen, Koji; Maeda, Yukihide; Sugaya, Akiko; Nishizaki, Kazunori

    2013-08-01

    Perilymphatic fistula (PLF) is defined as an abnormal leakage between perilymph from the labyrinth to the middle ear. Symptoms include hearing loss, tinnitus, and vertigo. The standard mode of PLF detection is intraoperative visualization of perilymph leakage and fistula, which ostensibly confirms the existence of PLF. Other possible methods of diagnosis include confirmation of pneumolabyrinth via diagnostic imaging. Recently, a cochlin-tomoprotein (CTP) detection test has been developed that allows definitive diagnosis of PLF-related hearing loss. We report the case of a 45-year-old man who presented with right-sided tinnitus, hearing loss, and dizziness 30 years after stapes surgery. Middle ear lavage was performed after myringotomy. A preoperative diagnosis of PLF was reached using the CTP detection test. Intraoperative observations included a necrotic long process of the incus, displaced wire piston, and fibrous tissue in the oval window. Perilymph leakage was not evident. The oval window was closed with fascia, and vertigo disappeared within 2 weeks postoperatively. When PLF is suspected after stapes surgery, the CTP detection test can be a useful, highly sensitive, and less invasive method for preoperative diagnosis. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  5. Congenital Stapes Ankylosis in Children: Surgical Findings and Results in 35 Cases.

    PubMed

    Vincent, Robert; Wegner, Inge; Kamalski, Digna M A; Bittermann, Arnold J N; Grolman, Wilko

    2016-04-01

    To evaluate surgical findings and hearing results in children undergoing middle ear surgery for congenital stapes ankylosis with or without other ossicular malformations (Teunissen and Cremers class I and class II malformations). A nonrandomized, nonblinded case series of prospectively collected data. A tertiary referral center. Twenty-eight consecutive pediatric patients who underwent 35 surgical procedures for congenital stapes ankylosis with or without other ossicular malformations and had available postoperative pure-tone audiometry. Primary stapedotomy with vein graft interposition and reconstruction with a Teflon piston, bucket handle prosthesis or total ossicular replacement prosthesis. Pre- and postoperative audiometric evaluation using four-frequency (0.5, 1, 2, and 4 kHz) audiometry. Air-conduction thresholds, bone-conduction thresholds, and air-bone gaps (ABGs) were measured. Postoperative audiometry was performed at 3, 6, 9, 12, 18, and 24 months after surgery and at a yearly interval thereafter. Overall, a postoperative ABG closure of 10 dB or less was achieved in 73% of class I cases and in 50% of class II cases. A postoperative ABG closure of 20 dB or less was achieved in 77% of class I cases and 67% of class II cases. Postoperative sensorineural hearing loss occurred in one class I case (4%) and none of the class II cases. Stapedotomy is a safe and feasible treatment option in children with congenital stapes ankylosis.

  6. Benefits of active middle ear implants in mixed hearing loss: Stapes versus round window.

    PubMed

    Lee, Jeon Mi; Jung, Jinsei; Moon, In Seok; Kim, Sung Huhn; Choi, Jae Young

    2017-06-01

    We compared the audiologic benefits of active middle ear implants with those of passive middle ear implants with hearing aids in mixed hearing loss, and also compared the outcomes of stapes vibroplasty with those of round window vibroplasty. Retrospective chart review. Thirty-four patients with mixed hearing loss due to chronic otitis media were treated with a middle ear implant. Of these, 15 were treated with a passive middle ear implant (conventional ossiculoplasty with a partial ossicular replacement prosthesis), nine with an active middle ear implant coupling to the stapes, and 10 with an active middle ear implant coupling to the round window. Patients underwent pure-tone/free-field audiograms and speech discrimination tests before surgery and 6 months after surgery, and the results of these tests were compared. The active middle ear implant resulted in better outcomes than the passive middle ear implant with hearing aids at mid to high frequencies (P < .05). Patients who received either a stapes vibroplasty or a round window vibroplasty showed comparable hearing gain except at 8,000 Hz (48.9 dB vs. 31.0 dB, P < .05). Patients who received a stapes vibroplasty showed an improvement even in bone conduction at 1,000 Hz and 2,000 Hz (both P < .05). Active middle ear implantation could be a better option than treatment with passive middle ear implants with hearing aids for achieving rehabilitation in patients with mixed hearing loss. Vibroplasty via either oval window or round window stimulation shares similar good results. 4 Laryngoscope, 127:1435-1441, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  7. [Comparative evaluation of vertigo in patients after stapedotomy and stapedectomy].

    PubMed

    Harmat, Kinga; Thurén, Gergely; Simon, László; Nepp, Nelli; Németh, Adrienn; Gerlinger, Imre; Bakó, Péter

    2017-09-01

    The reason of gradually developing conductive hearing loss in otosclerotic patients is the ossification of the stapes footplate to the surrounding bony structures and the therapy of stapes fixation is mainly surgical. In stapedotomy the footplate of the stapes is fenestrated with laser and microdrill in a diameter of 0.8 mm, whereas in stapedectomy there is complete removal of the footplate followed by the reconstruction of the ossicular chain. In the early postoperative period, temporary vertigo is frequently recorded which significantly influences the recovery. In the Department of Otorhinolaryngology, University of Pécs both stapedectomy and stapedotomy were performed on a daily basis between 01.02.2010 and 15.03.2012. Our study focused on comparing the degree of postoperative vertigo after the two types of surgery. We hypothesized that the smaller fenestration of the stapes footplate during stapedotomy limits exposure to the inner ear reducing the severity of dizziness. Vertigo was evaluated subjectively with a retrospective questionnaire and objectively with static posturography. On the 1st postoperative day, significantly fewer patients reported vertigo in the stapedotomy group and with significantly lower intensity. Results of the questionnaire regarding the later postoperative period showed no significant differences between the groups. Based on the analysis of the posturography test results, no significant difference was detected between the postoperative stability of the two groups. Results of the questionnaire and the posturography showed no correlation. Posturography test results did not confirm the presence of subjective vertigo. Many factors may play a role in the development of vertigo after stapes surgery, but the type of intervention does not influence it. Orv Hetil. 2017; 158(38): 1503-1511.

  8. [First experiences with a new nickel-titanium piston with a shape memory feature].

    PubMed

    Hornung, J; Zenk, J; Schick, B; Wurm, J; Iro, H

    2007-02-01

    The aim of this study was to describe a new stapes prosthesis with memory characteristics for wire crimping (SMart-Piston). This technique was used in 15 patients (mean age 43.4 years; range 28-71) undergoing routine stapes surgery. SMart-Piston prostheses with a shaft diameter of 0.5 mm and length ranging from 4.25-4.5 mm were used. Heat induced wire crimping was performed by CO2 laser in five patients, and by bipolar diathermy forceps in ten patients. In 15 patients, postoperative audiological testing was performed at an average 21.9 days and in another 10 again after 435 days following surgery. The median observed air-bone-gap (ABG) postoperatively was 8.7 dB+/-7.7 dB. A total of 73% of all patients had an ABG of 10 dB or less, and all patients had less than 20 dB. In the ten patients controlled after 435 days, the ABG was 4.4 dB+/-2.4 dB. It was lower than 10 dB in all individuals. A critical point in every stapes surgery, the prosthesis fixation to the incus, is greatly facilitated by this novel technique. Long-term results in a larger group of patients are pending.

  9. Cartilage island on stapes: autologous PORP in the hypoventilated middle ear.

    PubMed

    Hess-Erga, Jeanette; Engelen, Bart Lambertus Henricus Jozef; Vassbotn, Flemming Slinning

    2017-04-01

    The most common technique in sound restoration of the middle ear is prosthetic surgery. Hypoventilation of the middle ear may cause adhesive otitis or atelectasis resulting in a higher risk of prosthetic extrusion rate and recurrence of the underlying cholesteatoma. We report long-term results using an island of tragal cartilage as an autologous PORP in selected patients with poor middle ear ventilation. Retrospective chart reviews were performed for procedures involving 52 patients between year 2000 and 2009. All patients that underwent surgery using tragal cartilage interposed between the suprastructure of the stapes and the tympanic membrane were included in this study. Audiological parameters using four frequencies, 0.5, 1, 2 and 3 kHz, according to AAO-HNS guidelines, were assessed pre-and postoperatively. The hearing results on different PTA frequencies were also investigated. We report long-term follow-up of patients with hypoventilated middle ear with a success rate of 71% (ABG <20%). With regards to the ABG, the low frequency component (5 and 1 kHz) showed a significantly (p < 0.05) larger improvement of mean values after surgery as compared to the high-frequency component (2 and 3 kHz). Cartilage island PORP on stapes is a stable and efficient method for selected patients with chronic middle ear disease.

  10. [Effect of CO2 laser on prostheses used in middle ear surgery].

    PubMed

    Szymański, Marcin

    2005-01-01

    The use of CO2 laser is advocated in primary and revision stapes surgery. The aim of the study was to assess the effect of CO2 laser on stapes prostheses. CO2 laser was applied on several types of stapes prostheses and PORPs, with power settings suggested by the manufacturer (continuous wave, 2 W and 6 W; 0,05 s). Application of the laser on stainless steel or titanium prosthesis did not exert any effect on the structure of the prosthesis. The use of the laser on the Teflon piston caused superficial burning with power 2 W, and melting and holes in the piston with power settings at 6W. Similar plastipore prostheses were melting. Hydroxyapatite PORP shattered after application of the laser energy. Teflon and hydroxyapatite prostheses are easily damaged by the laser energy, therefore applying a laser on them should be avoided. CO2 laser can be used on stainless steel and titanium prostheses without risk of damaging them. However the possibility of transmission of heat to the vestibule has to be taken into consideration.

  11. Economic viability of stapes surgery in Germany.

    PubMed

    Savvas, E; Maurer, J

    2009-04-01

    The purpose of this study was to determine the economic viability of stapes surgery in Germany. We compared the cost of the operation to the retail value and average cost of a lifelong supply of hearing aids. Retrospective study. Tertiary referral centre. One hundred and sixty-four consecutive cases of primary stapedotomy performed on patients with otosclerosis at our institution served as the representative group for the calculation. The post-operative air-bone gap average at the frequencies 500, 1000, 2000 and 4000 Hz was less than 10 dB for 62 per cent of the patients, and less than 20 dB for 92 per cent of the patients. There was a post-operative sensorineural hearing loss in 1.2 per cent of the patients. Analysis showed that, even for an elderly patient aged 65 years with a life expectancy of 15 years, the cost of a lifelong supply of hearing aids was greater than that of a stapedotomy procedure. Based on our group of patients, the stapedotomy procedure proved to be euro 800,000 K cheaper than treatment with an averagely priced hearing aid. The economic benefit was still present when taking into account possible revision surgery in 5-10 per cent of cases, and also when, in addition to the surgery, a post-operative hearing aid was required, in for example 20 per cent of cases. Stapes surgery is economically beneficial for the individual patient as well as for the general patient cohort, irrespective of age. The stapedotomy procedure also prevents the known disadvantages of conventional hearing aids, thus improving the patient's quality of life.

  12. The crimping problem in stapes surgery.

    PubMed

    Kwok, Pingling; Fisch, Ugo; Strutz, Jürgen

    2007-01-01

    The goal of this study was to compare the attachment of stapes prostheses with differently shaped loops to the long process of the incus. Gold, steel/Teflon, platinum/Teflon, and two different titanium stapes prostheses were inserted in 30 specially prepared temporal bones by three experienced surgeons using the Fisch technique with the McGee crimper and straight alligator forceps for the crimping of the loops. In all prostheses, a sufficiently firm attachment of the long process of the incus was achieved. The band-shaped loops showed a better contact with the incus than did the wire loops. However, the broad spiral-shaped loops led to a loss of the perpendicular axis of the piston to the long incus process. The geometry of the loop affects the final length of the piston in the vestibule and its angle to the long process of the incus.

  13. Influence of Ossicular Chain Damage on Hearing After Chronic Otitis Media and Cholesteatoma Surgery: A Systematic Review and Meta-analysis.

    PubMed

    Blom, Erik F; Gunning, Marlise N; Kleinrensink, Nienke J; Lokin, Alexander S H J; Bruijnzeel, Hanneke; Smit, Adriana L; Grolman, Wilko

    2015-11-01

    Physicians should ideally be able to provide patients with chronic otitis media and/or cholesteatoma specific information about postoperative hearing outcome, based on their level of preoperative ossicular chain damage (OCD). To identify the influence of preoperative OCD on hearing outcomes in patients after chronic otitis media and/or cholesteatoma surgery. PubMed, EMBASE, and the Cochrane Library databases were systematically searched for available evidence, without any constraints, on December 13, 2014, for articles published between January 1, 1975, and December 13, 2014. We reviewed the literature for articles assessing the prognostic value of OCD on postoperative hearing outcome (air-bone gap [ABG] in decibels), using Austin-Kartush criteria or independent OCD classification systems. We assessed relevance and validity using a self-designed critical appraisal tool based on the Cochrane Collaboration's risk of bias tool. Characteristics of study populations and postoperative ABGs in decibels were extracted from all included studies by 4 authors (E.F.B., M.N.G., N.J.K., A.S.H.J.L.). The tested hypothesis was formulated before data collection. Primary study outcome was defined as postoperative adult hearing outcomes after COM and/or cholesteatoma surgery defined as mean postoperative ABG. Our search yielded 5661 articles. Nine articles with high relevance were included. Pooled results of studies using the Austin-Kartush criteria showed a significant (P < .001) difference in mean ABG in favor of group B, when comparing group B (patients with malleus present, stapes absent; 11.1 [95% CI, 10.3-11.8] dB) to group C (patients with malleus absent, stapes present; 15.7 [95% CI, 14.6-16.7] dB) and group B to group D (patients with malleus absent, stapes absent; 16.5 [95% CI, 15.2-17.9] dB). Three studies using independent OCD classification criteria found no influence of stapes structure (intact stapes suprastructure, 13.5 [95% CI, 10.3-16.7], 15.1 [95% CI, 11.8-18.3], and 21.9 [95% CI, 15.0-28.8] dB vs absent stapes structure, 12.8 [95% CI, 9.5-16.1], 19.5 [95% CI, 14.9-24.1], and 30.2 [95% CI, 24.7-35.8] dB) on postoperative ABG. One study reported a significant (P = .04) difference in mean ABG between patients with present (18.9 [95% CI, 15.7-22.1] dB) and absent (24.4 [95% CI, 20.2-28.6] dB) malleus. Pooled results of Austin-Kartush studies showed that in patients with COM, with or without cholesteatoma, the malleus status is a significant predictor of postoperative hearing outcome, independent of the stapes condition. Studies reporting on individual ossicle status supported this finding by showing that only malleus condition influenced postoperative hearing outcome. These findings are based on level IV evidence, which indicates the need for future high-level evidence studies.

  14. A new tool for testing ossicular mobility during middle ear surgery: preliminary report of four cases.

    PubMed

    Hato, Naohito; Kohno, Hisashi; Okada, Masahiro; Hakuba, Nobuhiro; Gyo, Kiyofumi; Iwakura, Takashi; Tateno, Makoto

    2006-08-01

    We developed an ossicular vibration tester for the objective and quantitative assessment of ossicular mobility, which is one of the most critical factors affecting postoperative hearing after tympanoplasty. Our device consists of three components: a probe shaft with a curved tip to be attached to the target ossicle, a vibration exciter to activate the probe, and a piezoelectric sensor to detect vibrations of the probe. These components are encased in a stainless steel holder, allowing easy hand manipulation during ear surgery. The probe is activated with an electric signal at around 1,600 Hz. The system is controlled with a laptop computer, and the results are presented as the ratio of the ossicular resistance (ROR) to a reference value as a percentage. One measurement takes 10 ms. The device was applied in four selected patients during ear surgery. Several measurements in two of the cochlear implantees showed a greater difference in the RORs of the stapes (15-20% in Case 1 and 35-45% in Case 2), whereas the RORs of the malleus and incus were within the same range. This was thought to correspond to the partial cochlear calcification noted in Case 2. In Case 3, who underwent surgery because of otosclerosis, the ROR of the stapes was high, ranging from 70 to 80%. When measured for the malleus-incus fixation anomaly (Case 4), the ROR of the malleus and incus was in the range of 60 to 70%. Owing to the limited surgical view, the ROR of the stapes could not be measured. No problems related to the measurements with this device were noted. The design, principles, measuring procedures, and preliminary results of our new tool for testing ossicular mobility are reported. Measuring the ossicular mobility during surgery may provide important information for deciding the surgical procedures.

  15. [Facial nerve monitoring during middle ear surgery: Results of a French survey].

    PubMed

    Mazzaschi, O; Juvanon, J-M; Mondain, M; Lavieile, J-P; Ayache, D

    2014-01-01

    Facial nerve injury is a rare complication of middle ear surgery. To date there is no widely accepted consensus on the use of intraoperative facial nerve monitoring during middle ear surgery, whereas its use has been proved as a valuable adjunct in neurotologic surgery. The purpose of our study was to identify introperative facial nerve monitoring practice patterns in France for middle ear surgery. A 19-item survey has been made up by three experienced otologists under the auspices of the French Otology and Neurotology Association. With the support of the French Society of Otolaryngology--Head and Neck Surgery, the survey was electronically sent by email to 1249 practicing ENT with a valid email address. Answers were analyzed two months later. Among 1249 email sent, 299 were opened (24%) and 83 answers were collected (6,6%). Of the respondents, 66% had access to intraoperative facial nerve monitoring. Otolaryngologists involved in academic setting were influenced by their teaching duty in 27%. Intraoperative facial nerve monitoring should not be required for stapes surgery, ossiculoplasty, myringoplasty for, respectively, 92%, 93 % and 98% of the respondents. In cochlear implantation, 78% of ear surgeons used facial nerve monitoring. Answers were more controversial for chronic ear surgery, ear atresia and middle ear implant. Revision surgery and CT scan can influence answers. Despite a low response rate, results of this national survey revealed interesting findings. For most of the respondents, intraoperative facial nerve monitoring was not indicated in stapes surgery, myringoplasty and ossiculoplasty. The use of intraoperative facial nerve monitoring for cochlear implantation was supported by the majority of respondents. Variations in response rate were more significant for chronic ear surgery, including middle ear cholesteatoma, and for ear atresia surgery.

  16. [High-resolution computed tomography in stapes surgery].

    PubMed

    Oberascher, G; Grobovschek, M

    1987-06-01

    Early and delayed complications in the inner or middle ear may follow stapedectomy or stapedotomy and may require revision surgery. Nowadays high resolution middle ear computed tomography (HR-MCT) using a special interpolation technique can demonstrate the smallest structures of the middle ear space, such as the long process of the incus and stapes. Stapes prostheses can also be seen in this way, but to identify the prothesis exactly it is necessary to determine the position of the piston hook in relation to the incus and of the piston shaft to the foot plate and scala vestibuli. Two points were of particular interest to us: HR-MCT identification of various metal and plastic pistons. Clinical significance of HR-MCT in complications following surgery. As the result of our experimental research on cadaver temporal bones, pistons must still be divided into four groups based on their demonstration by HR-MCT: Group I (e.g. Stainless Steel Cup Piston): whole piston visible. Group II (e.g. McGee Stainless Steel Piston): only piston shaft. Group III (Fisch Teflon-Platinum Piston): only hook visible. Group IV (e.g. Fisch Teflon-Wire Piston): piston hardly visible or not at all. In groups I-III it is possible to discover whether the piston is too long or too short, whether it is dislocated or has slipped. Group IV pistons, hooks from group II and the shaft from group III must be changed to allow detection by x-rays. With plastic pistons it might be possible to add an x-ray agent.2+ improvements in manufacture appear to be necessary, dislocation of various prostheses can now be shown.(ABSTRACT TRUNCATED AT 250 WORDS)

  17. A 1,470 nm diode laser in stapedotomy: Mechanical, thermal, and acoustic effects.

    PubMed

    Koenraads, Simone P C; de Boorder, Tjeerd; Grolman, Wilko; Kamalski, Digna M A

    2017-08-01

    Multiple laser systems have been investigated for their use in stapes surgery in patients with otosclerosis. The diode 1,470 nm laser used in this study is an attractive laser system because it is easily transported and relatively inexpensive in use. This wavelength has relative high absorption in water. This study aimed to investigate the mechanical, thermal, and acoustic effects of the diode 1,470 nm laser on a stapes in an inner ear model. Experiments were performed in an inner ear model including fresh frozen human stapes. High-speed imaging with frame rates up to 2,000 frames per second (f/s) was used to visualize the effects in the vestibule during fenestration of the footplate. A special high-speed color Schlieren technique was used to study thermal effects. The sound produced by perforation was recorded by a hydrophone. Single pulse settings of the diode 1,470 nm laser were 100 ms, 3 W. Diode 1,470 nm laser fenestration showed mechanical effects with small vapor bubbles and pressure waves pushed into the vestibule. Thermal imaging visualized an increase temperature underneath the stapes footplate. Acoustic effects were limited, but larger sounds levels were reached when vaporization bubbles arise and explode in the vestibule. The diode 1,470 nm laser highly absorbs in perilymph and is capable of forming a clear fenestration in the stapes. An overlapping laser pulse will increase the risk of vapor bubbles, pressure waves, and heating the vestibule. As long as we do not know the possible damage of these effects to the inner ear function, it seems advisable to use the laser with less potential harm. Lasers Surg. Med. 49:619-624, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  18. Comparison of Nitinol Stapes Pistons with Conventional Stapes Pistons: A Cadaver Study

    DTIC Science & Technology

    2011-01-01

    Comparison of Nitinol Stapes Pistons with Conventional Stapes Pistons: A Cadaver Study Samuel A. Spear1 and James V. Crawford2 1 48th Medical Group, ENT...cited. Objective. To visually compare the Nitinol “smart” stapes prosthesis to conventional manual crimping stapes pistons in temporal bone cadaver...answer questions about each stapes piston. The answers to the survey were then recorded for analysis. Results. 8 of 9 Nitinol pistons were described as

  19. Clinical assessment of ossicular mobility by a ceramic vibrator designed for implantable hearing aids.

    PubMed

    Gyo, K; Yanagihara, N

    1986-01-01

    Ossicular mobility was assessed by direct coupling of a piezoelectric ceramic vibrator to the ossicles during middle ear surgery. The sites excited were body of the incus, head of the stapes, and footplate of the stapes through a hydroxyapatite ceramic strut. The threshold of the vibratory hearing was determined by the patient's response as a minimum audition, and the vibration threshold was obtained by subtracting the preoperative bone conduction threshold from the vibratory hearing threshold. The results were analyzed by the state of hearing after the operation, which revealed that a patient with a good vibration threshold during the operation had a tendency to get good postoperative hearing. This may mean that postoperative hearing can be predicted to some extent during the operation by the measurement of ossicular mobility.

  20. Disintegration of porous polyethylene prostheses.

    PubMed

    Kerr, A G; Riley, D N

    1999-06-01

    A Plastipore (porous polyethylene) Total Ossicular Replacement Prosthesis gave an excellent initial hearing result which was maintained for 14 years. Hearing then began to deteriorate and revision surgery showed disintegration of the prosthesis and a defect in the stapes footplate. Histological examination confirmed previous findings in porous polyethylene with multinucleated foreign body giant cells and breakdown of the material.

  1. Oval Window Size and Shape: a Micro-CT Anatomical Study With Considerations for Stapes Surgery.

    PubMed

    Zdilla, Matthew J; Skrzat, Janusz; Kozerska, Magdalena; Leszczyński, Bartosz; Tarasiuk, Jacek; Wroński, Sebastian

    2018-06-01

    The oval window is an important structure with regard to stapes surgeries, including stapedotomy for the treatment of otosclerosis. Recent study of perioperative imaging of the oval window has revealed that oval window niche height can indicate both operative difficulty and subjective discomfort during otosclerosis surgery. With regard to shape, structures incorporated into the oval window niche, such as cartilage grafts, must be compatible with the shape of the oval window. Despite the clinical importance of the oval window, there is little information regarding its size and shape. This study assessed oval window size and shape via micro-computed tomography paired with modern morphometric methodology in the fetal, infant, child, and adult populations. Additionally, the study compared oval window size and shape between sexes and between left- and right-sided ears. No significant differences were found among traditional morphometric parameters among age groups, sides, or sexes. However, geometric morphometric methods revealed shape differences between age groups. Further, geometric morphometric methods provided the average oval window shape and most-likely shape variance. Beyond demonstrating oval window size and shape variation, the results of this report will aid in identifying patients among whom anatomical variation may contribute to surgical difficulty and surgeon discomfort, or otherwise warrant preoperative adaptations for the incorporation of materials into and around the oval window.

  2. Congenital middle ear abnormalities with absence of the oval window: diagnosis, surgery, and audiometric outcomes.

    PubMed

    Su, Yu; Yuan, Hu; Song, Yue-shuai; Shen, Wei-dong; Han, Wei-ju; Liu, Jun; Han, Dong-yi; Dai, Pu

    2014-08-01

    Congenital absence of the oval window (CAOW) is a rare condition in which the stapes footplate fails to develop, resulting in a significant conductive hearing loss in the affected ear. The purpose of this study was to describe the surgical management and outcomes of patients with CAOW undergoing the oval window drill-out (OWD) procedure. A retrospective chart review of patients with CAOW between 1996 and 2011 was performed. Clinical data of patients who underwent OWD were collected. Seventy-nine patients (103 ears) were confirmed using exploratory tympanotomy as having congenital stapes anomalies and CAOW without any anomalies of the tympanic membrane and external auditory canal. Demographic data, CT findings, operative findings, complications, and preoperative/postoperative audiometry data of patients who underwent OWD were collected. The preoperative and postoperative audiologic findings were analyzed in 42 patients (56 ears) with complete data. Hearing restoration surgery was aborted for various reasons in 14 cases. Six patients underwent revision operations for worsening hearing after their first surgery. The average preoperative 4 tone air conduction threshold was 67 dB; the average 6-month postoperative four tone air conduction threshold was 49 dB, and the average postoperative hearing gain was 18 dB. For the 56 ears, the average 4 tone air conduction threshold 6 months after surgery was significantly lower than the preoperative threshold. The oval window drill-out procedure is a viable operation for patients with congenital absence of the oval window, and it is important for surgeons to develop personalized treatment programs to improve patients' hearing with minimal complications.

  3. [Stapedotomie with the use of CO2 laser--"one shot" technique].

    PubMed

    Szyfter, Witold; Mielcarek-Kuchta, Daniela; Młodkowska, Anna; Miętkiewska-Leszniewska, Dorota; Obrębowska, Zofia; Łączkowska-Przybylska, Joanna

    2013-01-01

    CO2 laser is used in stapes surgery due to good water absorption and quite optimal ablation of a bony structure without the influence of inner ear parameters. the assessment of the influence of CO2 - "one shot" laser on hearing results in the patients group with otosclerosis. The study was carried out on a patients group after surgical treatment. The follow up time was at least 6 months. The hearing results were described according to the guidelines of the American Committee on Hearing and Equilibrium. The obtained results were statistically analysed with the use of the Wilcoxon sequence pair test. The CO2 - "one shot" laser has been used in Department of Otolaryngology in Poznań since July 2009. Using this system 101 operations were carried out to the end of December 2011. 54 patients were in the analysed group, there were 40 women and 14 men, the age range from 22 to 59. In the Wilcoxon sequence pair test there was a statistically significant correlation between the value of the hearing threshold in pre- and post-operative examinations at 0.5, 1, 2 and 3kHz for bone and air conduction. We found also a statistically significant correlation between the mean value of the air-bone gap before and after treatment. In the group after the surgery the cochlear reserved became closed or decreased (p<0.001). based of the hearing results we found great usefulness of CO2 - "one shot" laser in stapes surgery. Copyright © 2012 Polish Otorhinolaryngology - Head and Neck Surgery Society. Published by Elsevier Urban & Partner Sp. z.o.o. All rights reserved.

  4. The use of CO(2) laser in revision stapes surgery: experimental studies on heat transmission to the vestibule.

    PubMed

    Szymański, Marcin; Morshed, Kamal; Mills, Robert P

    2007-01-01

    The aim of the study was to assess the effect of CO(2) laser on stapes prostheses and measure the heat transmission to the vestibule in experiment model. CO(2) laser was applied on two types of prostheses with power settings (2 and 6W; 0.05 s). Transmission of heat to the 'vestibule' was measured using type K thermocouple and DC-80 data logger during application of the laser on prostheses using a training model of temporal bone. Application of the laser on stainless steel prosthesis did not have any effect on the structure of the prosthesis. The use of the laser on the fluoroplastic-wire piston caused melting and produced holes in the piston. Greater temperature rises occurred with stainless steel than with the fluoroplastic-wire piston. Application of CO(2) laser on stainless steel pistons with 6W can produce inner ear trauma. The use of the laser on fluoroplastic-wire piston is not likely to irritate the inner ear.

  5. PubMed

    Neudert, Marcus

    2018-06-01

    Heining et al. Audiological outcome of stapes surgery for far advanced cochlear otosklerosis. J Laryngol Otol 2017; 131: 961–964 DIE COCHLEäRE OTOSKLEROSE IST EINE SELTENE ERKRANKUNG DES INNENOHRES, DIE ZU EINER VERKNöCHERUNG DER HAARZELLEN FüHRT UND DIE HOMöOSTASE DER LYMPHSTRöME NEGATIV BEEINFLUSSEN KANN. BETROFFENE LEIDEN UNTER INNENOHRSCHWERHöRIGKEIT, EINE THERAPIE GILT ALS SCHWIERIG. HEINING UND KOLLEGINNEN/KOLLEGEN HABEN NUN IN EINER RETROSPEKTIVEN STUDIE UNTERSUCHT, OB PATIENTEN MIT FORTGESCHRITTENER OTOSKLEROSE VON EINER STAPEDOTOMIE PROFITIEREN KöNNEN.

  6. Simultaneous Measurements of Ossicular Velocity and Intracochlear Pressure Leading to the Cochlear Input Impedance in Gerbil

    PubMed Central

    Decraemer, W. F.; Khanna, S. M.; Olson, E. S.

    2008-01-01

    Recent measurements of three-dimensional stapes motion in gerbil indicated that the piston component of stapes motion was the primary contributor to intracochlear pressure. In order to make a detailed correlation between stapes piston motion and intracochlear pressure behind the stapes, simultaneous pressure and motion measurements were undertaken. We found that the scala vestibuli pressure followed the piston component of the stapes velocity with high fidelity, reinforcing our previous finding that the piston motion of the stapes was the main stimulus to the cochlea. The present data allowed us to calculate cochlear input impedance and power flow into the cochlea. Both the amplitude and phase of the impedance were quite flat with frequency from 3 kHz to at least 30 kHz, with a phase that was primarily resistive. With constant stimulus pressure in the ear canal the intracochlear pressure at the stapes has been previously shown to be approximately flat with frequency through a wide range, and coupling that result with the present findings indicates that the power that flows into the cochlea is quite flat from about 3 to 30 kHz. The observed wide-band intracochlear pressure and power flow are consistent with the wide-band audiogram of the gerbil. PMID:18459001

  7. [Applied anatomy of scala tympani inlet related to cochlear implantation].

    PubMed

    Zou, Tuanming; Guo, Menghe; Zhang, Hongzheng; Shu, Fan; Xie, Nanping

    2012-06-01

    To investigate the related parameters of the temporal bone structure for determining the position of implanting electrode into the scala tympani in cochlear implantation surgery through the facial recess and epitympanum approach. In a surgical simulation experiment, 20 human temporal bones were studied and measured to determine the related parameters of the temporal bone structure. The distance 5.91∓0.29 mm between the short process of the incus and the round window niche, 2.11∓0.18 mm between the stapes and the round window niche, 6.70∓0.19 mm between the facial nerve in the perpendicular paragraph and the round window niche, 2.22∓0.21 mm from the pyramidal eminence to the round window, and 2.16∓0.14 mm between the stapes and the round window. The minimal distance between the implanting electrode and the vestibular window was 2.12∓0.19 mm. The distance between the cochleariform process and the round window niche was 3.79∓0.17 mm. The position of the cochlear electrode array insertion into the second cochlear turn was 2.25∓0.13 mm under the stapes. The location of the cochlear electrode array insertion into the second cochlear turn was 2.28∓0.20 mm inferior to the pyramidal eminence. These parameters provide a reference value to determine the different positions of cochlear electrode array insertion into the scale tympani in different patients.

  8. Measurement of stapes vibration in Human temporal bones by round window stimulation using a 3-coil transducer.

    PubMed

    Shin, Dong Ho; Kim, Dong Wook; Lim, Hyung Gyu; Jung, Eui Sung; Seong, Ki Woong; Lee, Jyung Hyun; Kim, Myoung Nam; Cho, Jin Ho

    2014-01-01

    Round window placement of a 3-coil transducer offers a new approach for coupling an implantable hearing aid to the inner ear. The transducer exhibits high performance at low-frequencies. One remarkable feature of the 3-coil transducer is that it minimizes leakage flux. Thus, the transducer, which consists of two permanent magnets and three coils, can enhance vibrational displacement. In human temporal bones, stapes vibration was observed by laser Doppler vibrometer in response to round window stimulation using the 3-coil transducer. Coupling between the 3-coil transducer and the round window was connected by a wire-rod. The stimulation created stapes velocity when the round window stimulated. Performance evaluation was conducted by measuring stapes velocity. To verify the performance of the 3-coil transducer, stapes velocity for round window and tympanic membrane stimulation were compared, respectively. Stapes velocity by round window stimulation using the 3-coil transducer was approximately 14 dB higher than that achieved by tympanic membrane stimulation. The study shows that 3-coil transducer is suitable for implantable hearing aids.

  9. [Applied anatomy of facial recess and posterior tympanum related to cochlear implantation].

    PubMed

    Zou, Tuanming; Xie, Nanping; Guo, Menghe; Shu, Fan; Zhang, Hongzheng

    2012-05-01

    To investigate the related parameters of temporal bone structure in the surgery of cochlear implantation through facial recess approach so as to offer a theoretical reference for the avoidance of facial nerve injury and the accurate localization. In a surgical simulation experiment, twenty human temporal bones were studied. The correlation parameters were measured under surgical microscope. Distance between suprameatal spine and short process of incus was (12.44 +/- 0.51) mm. Width from crotch of chorda tympani nerve to stylomastoid foramen was (2.67 +/- 0.51) mm. Distance between short process of incus and crotch of chorda tympani nerve was (15.22 +/- 0.83) mm. The location of maximal width of the facial recess into short process of incus, crotch of chorda tympani nerve were (6.28 +/- 0.41) mm, (9.81 +/- 0.71) mm, respectively. The maximal width of the facial recess was (2.73 +/- 0.20) mm. The value at level of stapes and round window were (2.48 +/- 0.20 mm) and (2.24 +/- 0.18) mm, respectively. Distance between pyramidalis eminence and anterior round window was (2.22 +/- 0.21) mm. Width from stapes to underneath round window was (2.16 +/- 0.14) mm. These parameters provide a reference value to determine the position of cochlear inserting the electrode array into the scale tympani and opening facial recess firstly to avoid potential damage to facial nerve in surgery.

  10. Time Average Holography Study of Human Tympanic Membrane with Altered Middle Ear Ossicular Chain

    NASA Astrophysics Data System (ADS)

    Cheng, Jeffrey T.; Ravicz, Michael E.; Rosowski, John J.; Hulli, Nesim; Hernandez-Montes, Maria S.; Furlong, Cosme

    2009-02-01

    Computer-assisted time average holographic interferometry was used to study the vibration of the human tympanic membrane (TM) in cadaveric temporal bones before and after alterations of the ossicular chain. Simultaneous laser Doppler vibrometer measurements of stapes velocity were performed to estimate the conductive hearing loss caused by ossicular alterations. The quantified TM motion described from holographic images was correlated with stapes velocity to define relations between TM motion and stapes velocity in various ossicular disorders. The results suggest that motions of the TM are relatively uncoupled from stapes motion at frequencies above 1000 Hz.

  11. Clinical significance of stapedioplasty biomechanics: swimming, diving, flying after stapes surgery.

    PubMed

    Hüttenbrink, Karl-Bernd

    2007-01-01

    A piston prosthesis in stapedioplasty significantly modifies the function of the normal ossicular chain. Due to the fact that the ear works as a pressure receptor, a piston prosthesis will be displaced at ambient air pressure changes in a different way than the normal stapes. Our ear is constantly exposed to these pressure changes in daily live, for example during swallowing, with tubal opening, with wind gusts at the external ear, during flying, or diving. Temporal bone experiments showed that elevated static pressures, like in tympanometry, can displace a piston up to 0.5mm in the vestibule. These large movements, which are caused by the missing attachment of the piston to the annual ligament, may explain why a short piston can be lifted out of the footplate perforation (e.g. after sneezing) or a piston with excessive length might come into contact with the membranous labyrinth, causing vertigo with an inward movement. Flying or diving can be performed by the patients after stapedioplasty, provided that a test with tympanometry is tolerated without evoking vertigo.

  12. Estimation of the stapes-bone thickness in the stapedotomy surgical procedure using a machine-learning technique.

    PubMed

    Kaburlasos, V G; Petridis, V; Brett, P N; Baker, D A

    1999-12-01

    Stapedotomy is a surgical procedure aimed at the treatment of hearing impairment due to otosclerosis. The treatment consists of drilling a hole through the stapes bone in the inner ear in order to insert a prosthesis. Safety precautions require knowledge of the nonmeasurable stapes thickness. The technical goal herein has been the design of high-level controls for an intelligent mechatronics drilling tool in order to enable the estimation of stapes thickness from measurable drilling data. The goal has been met by learning a map between drilling features, hence no model of the physical system has been necessary. Learning has been achieved as explained in this paper by a scheme, namely the d-sigma Fuzzy Lattice Neurocomputing (d sigma-FLN) scheme for classification, within the framework of fuzzy lattices. The successful application of the d sigma-FLN scheme is demonstrated in estimating the thickness of a stapes bone "on-line" using drilling data obtained experimentally in the laboratory.

  13. Development of the stapes and associated structures in human embryos

    PubMed Central

    Rodríguez-Vázquez, JF

    2005-01-01

    The objective of this study was to clarify the development of the stapes in humans and its relationship with the cartilage of the second branchial arch. The study was carried out in 25 human embryos between 6 and 28 mm crown–rump length. The stapes develops at the cranial end of the second branchial arch through an independent anlage of the cartilage of this arch. Between the stapedial anlage and the cranial end of the Reichert's cartilage there is a formation called the interhyale, the internal segment of which gives rise to the tendon of the stapedial muscle. The stapedial anlage is a unique formation with two distinct parts: the superior part that will comprise the base and the inferior part that will be crossed by the stapedial artery during embryonic development and will constitute the limbs and the head of the stapes. According to the results, the otic capsule is not involved in formation of the base of the stapes. PMID:16050903

  14. Laser stepedotomy for otosclerosis.

    PubMed

    Perkins, R C

    1980-02-01

    The argon laser microscope recently developed by the author is used to vaporize the stapes tendon, the posterior crus and a rosette of holes in the stapes footplate in the surgical treatment of otosclerosis. An autogenous vein--stainless steel piston assembly is used to reconstruct the stapes portion of the ossicular chain. The surgical technique and results in a preliminary series of 11 patients are reported. Rationale and advantages over conventional stapedectomy are discussed.

  15. Computed tomographic imaging of stapes implants.

    PubMed

    Warren, Frank M; Riggs, Sterling; Wiggins, Richard H

    2008-08-01

    Computed tomographic (CT) imaging of stapes prostheses is inaccurate. Clinical situations arise in which it would be helpful to determine the depth of penetration of a stapes prosthesis into the vestibule. The accuracy of CT imaging for this purpose has not been defined. This study was aimed to determine the accuracy of CT imaging to predict the depth of intrusion of stapes prostheses into the vestibule. The measurement of stapes prostheses by CT scan was compared with physical measurements in 8 cadaveric temporal bones. The depth of intrusion into the vestibule of the piston was underestimated in specimens with the fluoroplastic piston by a mean of 0.5 mm when compared with the measurements obtained in the temporal bones. The depth of penetration of the stainless steel implant was overestimated by 0.5 mm when compared with that in the temporal bone. The type of implant must be taken into consideration when estimating the depth of penetration into the vestibule using CT scanning because the imaging characteristics of the implanted materials differ. The position of fluoroplastic pistons cannot be accurately measured in the vestibule. Metallic implants are well visualized, and measurements exceeding 2.2 mm increase the suspicion of otolithic impingement. Special reconstructions along the length of the piston may be more accurate in estimating the position of stapes implants.

  16. Expression of TNF-α, OPG, IL-1β and the presence of the measles virus RNA in the stapes of the patients with otosclerosis.

    PubMed

    Potocka-Bakłażec, Małgorzata; Sakowicz-Burkiewicz, Monika; Kuczkowski, Jerzy; Pawełczyk, Tadeusz; Stankiewicz, Czesław; Sierszeń, Wojciech; Jankowski, Zbigniew; Buczny, Jacek

    2015-08-01

    Persistent measles virus infections play a crucial role in the pathomechanism of otosclerosis. The study was undertaken to investigate the role of tumor necrosis factor-α (TNF-α), interleukin 1β (IL-1β) and osteoprotegerin (OPG) in otosclerotic bone remodeling and to assess the relation of TNF-α, OPG and IL-1β expression levels in otosclerotic stape footplates to the occurrence of measles virus infection. 61 patients with otosclerosis were treated surgically. Thirty-one stapes obtained from cadavers of people, who had died from a sudden cause were used as a control group. The presence of measles virus RNA and the expression levels of TNF-α, IL-1β and OPG in otosclerotic foci were assessed using one-step RT-PCR. The presence of measles virus RNA was noted in 80.3 % of otosclerotic stapes (49 out of 61) and 9.7 % of normal tissues (3 out of 31). Transcript of TNF-α, IL-1β and OPG was detected in 40, 46 and 18 virus-positive stapes, respectively. The transcript level of TNF-α and IL-1β was significantly higher in otosclerotic tissues comparing to normal tissue. The OPG expression level was significantly lower in otosclerotic tissues comparing to controls. The presence of measles virus RNA in the stapes may indicate its role in the pathogenesis of otosclerosis. The presence of TNF-α and IL-1β mRNA in the virus-positive stapes could be the result of viral antigen stimulation and may be a marker of inflammation the otosclerotic focus. The lack of OPG mRNA and the presence of TNF-α and IL-1β mRNA in the majority of otosclerotic tissues reflect the bone remodeling process occurring in the stapes.

  17. Comparison of stapedotomy minus prosthesis, circumferential stapes mobilization, and small fenestra stapedotomy for stapes fixation.

    PubMed

    Acar, Gül Ozbilen; Kivekäs, Ilkka; Hanna, Bassem M; Huang, Lin; Gopen, Quinton; Poe, Dennis S

    2014-04-01

    To compare the outcomes of 3 surgical techniques for primary stapes fixation: stapedotomy minus prosthesis (STAMP), circumferential stapes mobilization (CSM), and small fenestra stapedotomy (SFS). Retrospective review of 277 primary cases operated for stapes fixation from 1997 to 2007. Tertiary academic center. Consecutive adult and pediatric cases operated for conductive hearing loss because of stapes fixation. STAMP was performed for otosclerosis limited to the anterior footplate, CSM was conducted for congenital stapes fixation, SFS was performed for more extensive otosclerosis or anatomic contraindications to STAMP/CSM. Pure-tone audiometry was performed preoperatively and postoperatively (3-6 wk) and the most recent long-term results (≥ 12 mo). Ninety-nine ears in 90 patients had audiologic follow-up data over 12 months. Sixty-seven ears (68%) underwent SFS, 16 (16%) STAMP, and 16 (16%) CSM. There was significant improvement in average air conduction (AC) thresholds and air-bone gap (ABG) for all techniques. Mean ABG for SFS closed from 29 to 7.1 dB (SD, 6.0), for STAMP from 29 to 3.8 dB (SD, 5.8 dB), and for CSM from 34 to 20 dB (SD, 8.2 dB). AC results were better in the STAMP than in the SFS group, especially in high frequencies. Bone conduction improvements were seen in all groups, highest in STAMP (4.3 dB) and CSM (3.8 dB) groups, but the differences between groups were not statistically significant. Satisfactory hearing results were achieved with all the techniques, and STAMP showed better hearing outcomes, especially in high frequencies. CSM is a good option for children and patients in whom it is desirable to avoid a footplate fenestration or prosthesis. CSM and STAMP had significantly higher rates of revision for refixation than SFS.

  18. Requirement for Jagged1-Notch2 signaling in patterning the bones of the mouse and human middle ear.

    PubMed

    Teng, Camilla S; Yen, Hai-Yun; Barske, Lindsey; Smith, Bea; Llamas, Juan; Segil, Neil; Go, John; Sanchez-Lara, Pedro A; Maxson, Robert E; Crump, J Gage

    2017-05-31

    Whereas Jagged1-Notch2 signaling is known to pattern the sensorineural components of the inner ear, its role in middle ear development has been less clear. We previously reported a role for Jagged-Notch signaling in shaping skeletal elements derived from the first two pharyngeal arches of zebrafish. Here we show a conserved requirement for Jagged1-Notch2 signaling in patterning the stapes and incus middle ear bones derived from the equivalent pharyngeal arches of mammals. Mice lacking Jagged1 or Notch2 in neural crest-derived cells (NCCs) of the pharyngeal arches display a malformed stapes. Heterozygous Jagged1 knockout mice, a model for Alagille Syndrome (AGS), also display stapes and incus defects. We find that Jagged1-Notch2 signaling functions early to pattern the stapes cartilage template, with stapes malformations correlating with hearing loss across all frequencies. We observe similar stapes defects and hearing loss in one patient with heterozygous JAGGED1 loss, and a diversity of conductive and sensorineural hearing loss in nearly half of AGS patients, many of which carry JAGGED1 mutations. Our findings reveal deep conservation of Jagged1-Notch2 signaling in patterning the pharyngeal arches from fish to mouse to man, despite the very different functions of their skeletal derivatives in jaw support and sound transduction.

  19. Surgery of the ear and the lateral skull base: pitfalls and complications

    PubMed Central

    Schick, Bernhard; Dlugaiczyk, Julia

    2013-01-01

    Surgery of the ear and the lateral skull base is a fascinating, yet challenging field in otorhinolaryngology. A thorough knowledge of the associated complications and pitfalls is indispensable for the surgeon, not only to provide the best possible care to his patients, but also to further improve his surgical skills. Following a summary about general aspects in pre-, intra-and postoperative care of patients with disorders of the ear/lateral skull base, this article covers the most common pitfalls and complications in stapes surgery, cochlear implantation and surgery of vestibular schwannomas and jugulotympanal paragangliomas. Based on these exemplary procedures, basic “dos and don’ts” of skull base surgery are explained, which the reader can easily transfer to other disorders. Special emphasis is laid on functional aspects, such as hearing, balance and facial nerve function. Furthermore, the topics of infection, bleeding, skull base defects, quality of life and indication for revision surgery are discussed. An open communication about complications and pitfalls in ear/lateral skull base surgery among surgeons is a prerequisite for the further advancement of this fascinating field in ENT surgery. This article is meant to be a contribution to this process. PMID:24403973

  20. [Complications and pitfalls in surgery of the ear/lateral skull base].

    PubMed

    Schick, B; Dlugaiczyk, J

    2013-04-01

    Surgery of the ear and the lateral skull base is a fascinating, yet challenging field in otorhinolaryngology. A thorough knowledge of the associated complications and pitfalls is indispensable for the surgeon, not only to provide the best possible care to his patients, but also to further improve his surgical skills.Following a summary about general aspects in pre-, intra- and postoperative care of patients with disorders of the ear/lateral skull base, this article covers the most common pitfalls and complications in stapes surgery, cochlear implantation, surgery of vestibular schwannomas, and jugulotympanal paragangliomas. Based on these exemplary procedures, basic "do's and don'ts" of skull base surgery are explained, which the reader can easily transfer to other disorders. Special emphasis is laid on functional aspects, such as hearing, balance and facial nerve function. Furthermore, the topics of infection, bleeding, skull base defects, quality of life and indication for revision surgery are discussed.An open communication about complications and pitfalls in ear/lateral skull base surgery among surgeons is a prerequisite for the further advancement of this fascinating field in ENT surgery. This article is meant to be a contribution to this process. © Georg Thieme Verlag KG Stuttgart · New York.

  1. Effects of middle ear quasi-static stiffness on sound transmission quantified by a novel 3-axis optical force sensor.

    PubMed

    Dobrev, Ivo; Sim, Jae Hoon; Aqtashi, Baktash; Huber, Alexander M; Linder, Thomas; Röösli, Christof

    2018-01-01

    Intra-operative quantification of the ossicle mobility could provide valuable feedback for the current status of the patient's conductive hearing. However, current methods for evaluation of middle ear mobility are mostly limited to the surgeon's subjective impression through manual palpation of the ossicles. This study investigates how middle ear transfer function is affected by stapes quasi-static stiffness of the ossicular chain. The stiffness of the middle ear is induced by a) using a novel fiber-optic 3-axis force sensor to quantify the quasi-static stiffness of the middle ear, and b) by artificial reduction of stapes mobility due to drying of the middle ear. Middle ear transfer function, defined as the ratio of the stapes footplate velocity versus the ear canal sound pressure, was measured with a single point LDV in two conditions. First, a controlled palpation force was applied at the stapes head in two in-plane (superior-inferior or posterior-anterior) directions, and at the incus lenticular process near the incudostapedial joint in the piston (lateral-medial) direction with a novel 3-axis PalpEar force sensor (Sensoptic, Losone, Switzerland), while the corresponding quasi-static displacement of the contact point was measured via a 3-axis micrometer stage. The palpation force was applied sequentially, step-wise in the range of 0.1-20 gF (1-200 mN). Second, measurements were repeated with various stages of stapes fixation, simulated by pre-load on the stapes head or drying of the temporal bone, and with severe ossicle immobilization, simulated by gluing of the stapes footplate. Simulated stapes fixation (forced drying of 5-15 min) severely decreases (20-30 dB) the low frequency (<1 kHz) response of the middle ear, while increasing (5-10 dB) the high frequency (>4 kHz) response. Stapes immobilization (gluing of the footplate) severely reduces (20-40 dB) the low and mid frequency response (<4 kHz) but has lesser effect (<10 dB) at higher frequencies. Even moderate levels of palpation force (<3gF, <30 mN), regardless of direction, have negative effect (10-20 dB) on the low frequency (<2 kHz) response, but with less significant (5-10 dB) effect at higher frequencies. Force-displacement measurements around the incudostapedial joint showed quasi-static stiffness in the range of 200-500 N/m for normal middle ears, and 1000-2500 N/m (5-8-fold increase) after artificially (through forced drying) reducing the middle ear transfer function with 10-25 dB at 1 kHz. Effects of the palpation force level and direction, as well as stapes fixation and immobilization have been analyzed based on the measurement of the stapes footplate motion, and controlled application of 3D force and displacement. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Safety of magnetic resonance imaging of stapes prostheses.

    PubMed

    Syms, Mark James

    2005-03-01

    Assess the safety of performing magnetic resonance imaging (MRI) on patients with stapes prostheses. Survey and animal model. A survey regarding implant usage, MRI procedures, and adverse outcomes after MRI in patients previously undergoing stapes procedures. Guinea pigs implanted with ferromagnetic 17 to 4 stainless steel, 316L nonferromagnetic stainless steel, titanium, and fluoroplastic stapes prostheses underwent a MRI in a 4.7 Tesla MR system. : Three adverse outcomes were reported on the clinical survey. One adverse event occurred during an MRI performed on a recalled ferromagnetic prosthesis. The other two adverse events were probably not secondary to MRI exposure. No damage or inflammation was observed in the region of the oval window or vestibule of implanted guinea pigs exposed to a 4.7 Tesla MR system. The combination of prior studies, the clinical survey, and the absence of histopathologic evidence of damage in the guinea pigs is compelling evidence that MRI for patients with stapes prostheses is safe. Implanting physicians should feel comfortable clearing a patient for a MRI in a 1.5 Tesla or 3.0 Tesla MRI. It is imperative for the physician to qualify the field strength when clearing a patient to undergo a MRI.

  3. Biocompatible membrane of PDMS for the new chamber prosthesis stapes.

    PubMed

    Banasik, Katarzyna; Kwacz, Monika

    2016-06-30

    Stapes protheses are designed for patients with otosclerosis resulting immobilization or significant reduction of the stapes mobility. All currently used prostheses are called - piston prosthesis. However, its use to stimulate the cochlea is still imperfect. New chamber stapes prosthesis allows the perilymph excitation more effective than the piston prothesis. Moreover, the chamber prosthesis eliminates the common causes of piston-stapedotomy failures. The most important element of the new prosthesis is a flexible membrane. The membrane stiffness should be close to the stiffness of normal annular ligament. This work presents the process of selection of the membrane's thickness and its manufacturing technology. Method A 3D model of the chamber stapes prosthesis was build using Autodesk Inventor 2015. The model was imported to Abacus 6.13 computing environment. During numerical simulations, displacements corresponding to applied loads were calculated and the membrane thickness was adjusted so that its stiffness was the same as the ligament stiffness (~ 120 N/m). The compliance ratios calculated from the load-displacement curves for the membrane and the annular ligament were verified using linear regression analysis. After determining the thickness, the manufacturing technology of the membrane was developed. Results The best similarity between the membrane's and annular ligament's stiffness was achieved for PDMS membrane with the 0,15- mm thickness (similarity ratio R2=0,997752). In this work, the technological parameters of spin-coating process for membrane manufacture are also presented. Summary The proper functioning of the chamber stapes prosthesis requires the PDMS membrane with a thickness of 0,15 mm. The 0,15-mm membrane has the tiffness close to the stiffness of the normal annular ligament. Therefore, the chamber stapes prosthesis provides the perilymph stimulation at the level comparable to the healthy ear. New prosthesis is currently under pre-clinical investigation to optimize the shape of the inner chamber's surface.

  4. Modeling sound transmission of human middle ear and its clinical applications using finite element analysis.

    PubMed

    Chen, Shou-I; Lee, Ming-Hsiao; Yao, Chih-Min; Chen, Peir-Rong; Chou, Yuan-Fang; Liu, Tien-Chen; Song, Yu-Lin; Lee, Chia-Fone

    2013-03-01

    We have developed a new finite element (FE) model of human right ear, including the accurate geometry of middle ear ossicles, external ear canal, tympanic cavity, and mastoid cavity. The FE model would be suitable to study the dynamic behaviors of pathological middle ear conditions, including changes of stapedial ligament stiffness, tensor tympani ligament (TTL), and tympanic membrane (TM) stiffness and thickness. Increasing stiffness of stapedial ligament has substantial effect on stapes footplate movement, especially at low frequencies, but less effect on umbo movement. Softer TTL will result in increasing umbo and stapes footplate displacement, especially at low frequencies (f<1000Hz). When the TTL was detached, the vibration amplitude of umbo increased by 6dB at 600Hz and two peaks (300 and 600Hz) were found in the vibration amplitude of stapes footplate. Increasing the stiffness of tensor tympani resulted in a slightly decreased umbo amplitude at very low frequencies (f<500Hz) and significantly decreased displacement up to 12dB at middle frequencies (1000Hz1500Hz. As (TM) thickness was increased, the umbo displacement was reduced, especially at very low frequencies (f<600Hz). Otherwise, the stapes displacement was reduced at all frequencies. Copyright © 2013. Published by Elsevier B.V.

  5. A New Intraoperative Real-time Monitoring System for Reconstructive Middle Ear Surgery: An Experimental and Clinical Feasibility Study.

    PubMed

    Zahnert, Thomas; Metasch, Marie-Luise; Seidler, Hannes; Bornitz, Matthias; Lasurashvili, Nicoloz; Neudert, Marcus

    2016-12-01

    Electromagnetical excitation of ossicular vibration is suitable for middle ear transmission measurements in the experimental and clinical setting. Thereby, it can be used as a real-time monitoring system for quality control in ossiculoplasty. Positioning and coupling of middle ear prosthesis are a precondition for good postoperative hearing results, but at the same time completely dependent upon the surgeon's subjective judgment during surgery. We evaluated an electromagnetically driven measurement system that enables for in vitro and in vivo transmission measurements and thus can be used as a real-time monitoring tool in ossicular reconstruction. For electromagnetical excitation a magnet was placed on the umbo of the malleus handle and driven by a magnetic field. The induced stapes displacement was picked up by laser Doppler vibrometry on the footplate. Measurements were performed on the intact ossicular chain in five cadaveric temporal bones and during five cochlear implant surgeries. Additionally, two ossiculoplasties were performed under real-time transmission feedback with the monitoring system. Experimentally, the equivalent sound pressure level of the electromagnetic excitation was about 70 to 80 dB which is 10 to 20 dB less than the acoustic stimulation. In the intraoperative setup the generated stapes displacements were about 5 to 20 dB smaller compared with the temporal bone experiments. Applied as real-time feedback system, an improvement in the middle ear transfer function of 4.5 dB in total and 20 dB in partial ossicular reconstruction were achieved. The electromagnetical excitation and measurement system is comparable to the gold standard with acoustical stimulation in both, the experimental setup in temporal bones as well as in vivo. The technical feasibility of the electromagnetical excitation method has been proven and it is shown that it can be used as a real-time monitoring system for ossiculoplasty in the operation room.

  6. Audiological comparison between two different clips prostheses in stapes surgery.

    PubMed

    Potena, M; Portmann, D; Guindi, S

    2015-01-01

    To compare audiometric results and complications of stapes surgery with two different types of piston prosthesis, the Portmann Clip Piston (Medtronic) (PCP) and the Soft Clip Piston (Kurz) (SCP). Study conducted on 64 patients who underwent primary stapedotomy from 2008 to 2011. We matched for each case of stapedotomy with the PCP (Medtronic Xomed Inc. Portmann Clip Piston Stainless Steel/Fluoroplastic) a case with the SCP (Heinz Kurz GmbH Medizintechnik Soft Piston Clip Titanium). Each group consisted of 32 patients, and patients in both groups were matched with respect to gender, age, bilateral or unilateral otosclerosis, otological symptoms (tinnitus, vertigo or dizziness), family history, operated side and the Portmann grading for otosclerosis. The length of the prosthesis used was reported. Post-operative complications such as tinnitus, vertigo, hearing loss and altered taste were documented. Each patient was subjected to a preoperative and postoperative audiogram (follow-up at the second month after the surgery). We used the Student test for statistical analysis. Statistical significance was set at < 0.01. None of the patients experienced a post-operative hearing loss and none required a later revision surgery. No statistically significant difference was found between the two populations regarding demographic data (age, sex, side, bilaterality, family history, stage and lenght of piston) and hearing level (> 0.01) in the air, bone conduction and air-bone gap (ABG). Postoperative complications did not result to be significantly different between the two groups. Also, both groups showed a significant improvement (< 0.01) in the post-operative air, bone conduction and air-bone gap. There was no statistically significant difference (> 0.01) between the post-operative hearing results (bone conduction, air conduction, air-bone gap) using the two pistons. The mean ABG improvement was respectively 16.63 dB in the SCP group and 20.59 dB in the PCP group. The titanium Soft clip piston (SCP) is a good alternative to the Portmann clip piston (PCP). Nevertheless there are some differences in the surgical fixing of these two pistons in the correct position.

  7. Antifibrotic effect of dexamethasone/alginate-coated silicone sheet in the abraded middle ear mucosa.

    PubMed

    Jang, Chul Ho; Ahn, Seung Hyun; Kim, Geun Hyung

    2016-12-01

    Silicone sheet is a material which is commonly used in middle ear surgery to prevent the formation of adhesions between the tympanic membrane and the medial bony wall of the middle ear cavity. However, silicone sheet can induce a tight and hard fibrous capsule in the region of the stapes, and this is particularly common in cases of eustachian tube dysfunction. As a result of the fibrous encapsulation around the silicone sheet, postoperative aeration of the stapes can be interrupted causing poor hearing gain. In this study, we performed an in vitro and in vivo evaluation of the antifibrotic effects of a dexamethasone and alginate (Dx/alginate) coating on silicone sheet. The Dx/alginate-coated silicone sheets were fabricated using a plasma-treatment and coating method. The Dx/alginate-coated silicone sheets effectively limited in vitro fibroblast attachment and proliferation due to the controlled release of Dx, which can be modified by manipulation of the alginate coating. For the in-vivo evaluation, guinea pigs (albino, male, weighing 250g) were divided into two groups, with the control group (n=5) implanted with silicone sheet and the test group (n=5) receiving Dx/alginate-coated silicone sheet. Animals were sacrificed 3 weeks after implantation, and histological analysis was performed using hematoxylin and eosin (H&E) and immunohistochemical staining techniques. Dx/alginate-coated silicone sheets showed marked inhibition of fibrosis in both the in vitro and in vivo studies. Silicone sheet that incorporates a Dx/alginate coating can release Dx and inhibit fibrosis in the middle ear. This material could be utilized in middle ear surgery as a means of preserving proper aeration and hearing gain following ossiculoplasty. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Comparison of Free-Beam- and Fiber-Type CO2 Laser Delivery Systems in Stapes Surgery.

    PubMed

    Chang, Mun Young; Choi, Hyun Seok; Lee, Sang-Youp; Koo, Ja-Won

    2017-07-01

    A free-beam-type CO 2 laser, which use a micromanipulator mounted on a microscope as the delivery system, has the merit of not being affected by hand tremor at the time of shooting. However, this delivery system has several disadvantages, including a restricted operation range and a risk of incorrect focusing. A fiber-type CO 2 laser uses a hand-held delivery system and has the opposite merits and demerits. We compared the results of stapes surgery with free-beam and fiber type delivery systems. The study enrolled 36 patients who underwent stapedotomy with free-beam- (n=26) or fiber- (n=10) type CO 2 lasers. The air-bone (AB) gap closure, bone conduction (BC) change, and operating time were evaluated. The AB gap closure was calculated by subtracting the preoperative BC thresholds from the postoperative air conduction thresholds. The BC change was calculated by subtracting the postoperative BC thresholds from the preoperative BC thresholds. The mean operating time was significantly ( p =0.035) shorter in the fiber-type group (72.5±8.2 min) than in the free-beam-type group (80.5±11.4 min). The mean AB gap closure did not differ significantly ( p =0.297) between the free-beamand fiber-type groups (5.8±10.1 and 1.4±6.8 dB, respectively). The mean BC change did not differ significantly ( p =0.873) between the free-beam- and fiber-type groups (2.4±6.9 and 2.8±5.3 dB, respectively). The hearing outcomes did not differ significantly between the two groups. Operating times were significantly shorter using the fiber-type CO 2 laser, while hearing outcomes did not differ significantly between the two groups.

  9. MPR-CT Imaging for Stapes Prosthesis: Accuracy and Clinical Significance.

    PubMed

    Fang, Yanqing; Wang, Bing; Galvin, John J; Tao, Duoduo; Deng, Rui; Ou, Xiong; Liu, Yangwenyi; Dai, Peidong; Sha, Yan; Zhang, Tianyu; Chen, Bing

    2016-04-01

    The aims of this article are: 1) to re-evaluate the accuracy of multiple planar reconstruction computed tomography (MPR-CT) imaging on stapes-prosthesis parameters, and 2) to clarify possible relationships between prosthesis intravestibular depth and postoperative hearing outcomes. Seventy patients (46 women and 24 men; 32 right and 38 left sides) with the mean age of 40 years (range, 19-62 yr) with clinical otosclerosis. All patients underwent stapedotomy and were implanted with the same type of titanium piston prosthesis by the same surgeon. Postoperative MPR-CTs were obtained at patients' follow-up visits. The length and intravestibular depth of the stapes prosthesis (including absolute and relative depth) were calculated from the MPR-CT imaging. Relationships between the intravestibular depth of the prosthesis and hearing outcomes (pre- and postoperative audiograms) were analyzed using Spearman correlation analyses. The length of the prosthesis was overestimated by 1.8% (0.1 mm) by the MPR-CT imaging. Axial and coronal measurements were significantly correlated (p < 0.05). There was great intersubject variability in hearing outcomes differed insignificantly, regardless of intravestibular depth within the security range. No relationships were found between the intravestibular depth of the stapes prosthesis, as measured with MPR-CT, and postoperative hearing results. MPR-CT can provide an accurate estimation of stapes prosthesis parameters. However, the prosthesis intravestibular depth did not seem to affect postoperative hearing outcomes.

  10. [Preparation and clinical application of Teflon-wire piston and stapes height measurer].

    PubMed

    Xie, Nan-ping

    2003-08-01

    With Teflon, and a tiny stainless steel needle of a number 7 injector and an acupuncture needle,Teflon-piston and a measurer of the stapes height were prepared respectively of stapedectomy for treatment of otosclerosis. Good clinical results were achieved with these simple and useful devices.

  11. Patterns of anomalies of structures of the middle ear and the facial nerve as revealed in newborn temporal bones.

    PubMed

    Tóth, Miklós; Sirirattanapan, Jarinratn; Mann, Wolf

    2013-08-01

    The purpose of this study is to offer new data about facial nerve malformations in the tympanic cavity. Prospective anatomic study of newborns to demonstrate the submacroscopic anatomy of the intratympanic facial nerve and its surrounding structures by malformations. Step-by-step microdissection of 12 newborn temporal bones and histologic evaluation of 4 middle ears showing multiple malformations. Four of 12 temporal bones presented malformation in the middle ear. All 4 temporal bones showed developmental failures of the stapes, and 3 of them had malposition of the tympanic portion of the facial nerve. In 3 cases, there was an oval window atresia, and in 1 case, the rim of the oval window was not ossified and was positioned medial to the stapes. Malformation or displacement of the stapes can be an indirect sign for facial nerve malformation. The most common site for facial nerve malformation is the tympanic portion. The tympanic segment of the nerve is devoid of bony covering in association with these anomalies of the stapes.

  12. Comparison of titanium and Robinson stainless steel stapes piston prostheses.

    PubMed

    Lippy, William H; Burkey, John M; Schuring, Arnold G; Berenholz, Leonard P

    2005-09-01

    Although stainless steel stapes prostheses have generally been considered magnetic resonance imaging safe, there is concern that this may change with the development of more powerful imaging systems. The objective of the study was to determine whether a titanium piston stapes prosthesis would be audiometrically and surgically equivalent to a Robinson stainless steel piston for stapedectomy. Retrospective chart review. Private otology practice. In all, 50 patients underwent stapedectomy with a Gyrus titanium piston prosthesis. These patients were matched on the basis of age and preoperative bone-conduction scores with patients who underwent stapedectomy with a Robinson stainless steel piston prosthesis. Audiometric results are analyzed, and surgical complications noted. There was no significant difference between groups in hearing improvement or postoperative air-bone gap. The mean four-frequency hearing improvement was 27.7 dB for the stainless steel group and 27.8 dB for the titanium group. The mean postoperative air-bone gap was 2.65 dB for the stainless steel group and 2.60 for the titanium group. Neither group had a surgical complication. The titanium stapes prosthesis is a good alternative to a stainless steel prosthesis.

  13. The effect of superior-canal opening on middle-ear input admittance and air-conducted stapes velocity in chinchilla

    PubMed Central

    Songer, Jocelyn E.; Rosowski, John J.

    2009-01-01

    The recent discovery of superior semicircular canal (SC) dehiscence syndrome as a clinical entity affecting both the auditory and vestibular systems has led to the investigation of the impact of a SC opening on the mechanics of hearing. It is hypothesized that the hole in the SC acts as a “third window” in the inner ear which shunts sound-induced stapes volume velocity away from the cochlea through the opening in the SC. To test the hypothesis and to understand the third window mechanisms the middle-ear input admittance and sound-induced stapes velocity were measured in chinchilla before and after surgically introducing a SC opening and after patching the opening. The extent to which patching returned the system to the presurgical state is used as a control criterion. In eight chinchilla ears a statistically significant, reversible increase in low-frequency middle-ear input admittance magnitude occurred as a result of opening the SC. In six ears a statistically significant reversible increase in stapes velocity was observed. Both of these changes are consistent with the hole creating a shunt pathway that increases the cochlear input admittance. PMID:16875223

  14. The effect of superior-canal opening on middle-ear input admittance and air-conducted stapes velocity in chinchilla.

    PubMed

    Songer, Jocelyn E; Rosowski, John J

    2006-07-01

    The recent discovery of superior semicircular canal (SC) dehiscence syndrome as a clinical entity affecting both the auditory and vestibular systems has led to the investigation of the impact of a SC opening on the mechanics of hearing. It is hypothesized that the hole in the SC acts as a "third window" in the inner ear which shunts sound-induced stapes volume velocity away from the cochlea through the opening in the SC. To test the hypothesis and to understand the third window mechanisms the middle-ear input admittance and sound-induced stapes velocity were measured in chinchilla before and after surgically introducing a SC opening and after patching the opening. The extent to which patching returned the system to the presurgical state is used as a control criterion. In eight chinchilla ears a statistically significant, reversible increase in low-frequency middle-ear input admittance magnitude occurred as a result of opening the SC. In six ears a statistically significant reversible increase in stapes velocity was observed. Both of these changes are consistent with the hole creating a shunt pathway that increases the cochlear input admittance.

  15. Prostheses for stapes surgery.

    PubMed

    Slattery, W H; House, J W

    1995-04-01

    A variety of different implants are available today for use by the otologic surgeon. All prostheses are well tolerated, and the risks of complication as a result of their implantation are comparable. The most commonly used prostheses are the wire-Teflon piston and the stainless steel bucket handle. Although the otologic surgeon has a wide variety of prostheses to choose from, most have a preference for one particular type. Results of hearing improvement following a successful stapedectomy is more a function of the surgeon's experience than of the type of prosthesis used. As James L. Sheehy, MD, so often says, "if a technique is working well for you, don't change for change's sake" (personal communication, 1994).

  16. Effect of Round Window Reinforcement on Hearing: A Temporal Bone Study With Clinical Implications for Surgical Reinforcement of the Round Window.

    PubMed

    Wegner, Inge; Eldaebes, Mostafa M A S; Landry, Thomas G; Adamson, Robert B; Grolman, Wilko; Bance, Manohar L

    2016-06-01

    Round window reinforcement leads to conductive hearing loss. The round window is stiffened surgically as therapy for various conditions, including perilymphatic fistula and superior semicircular canal dehiscence. Round window reinforcement reduces symptoms in these patients. However, it also reduces fluid displacement in the cochlea and might therefore increase conductive hearing loss. Perichondrium was applied to the round window membrane in nine fresh-frozen, nonpathologic temporal bones. In four temporal bones cartilage was applied subsequently. Acoustic stimuli in the form of frequency sweeps from 250 to 8000 Hz were generated at 110 dB sound pressure level. A total of 16 frequencies in a 1/3-octave series were used. Stapes velocities in response to the acoustic stimuli were measured at equally spaced multiple points covering the stapes footplate using a scanning laser Doppler interferometry system. Measurements were made at baseline, after applying perichondrium, and after applying cartilage. At frequencies up to 1000 Hz perichondrium reinforcement decreased stapes velocities by 1.5 to 2.9 dB compared with no reinforcement (p value = 0.003). Reinforcement with cartilage led to a further deterioration of stapes velocities by 2.6 to 4.2 dB at frequencies up to 1000 Hz (p value = 0.050). The higher frequencies were not affected by perichondrium reinforcement (p value = 0.774) or cartilage reinforcement (p value = 0.644). Our results seem to suggest a modest, clinically negligible effect of reinforcement with perichondrium. Placing cartilage on the round window resulted in a graded effect on stapes velocities in keeping with the increased stiffness of cartilage compared with perichondrium. Even so, the effect was relatively small.

  17. Early hominin auditory ossicles from South Africa

    PubMed Central

    Quam, Rolf M.; de Ruiter, Darryl J.; Masali, Melchiorre; Arsuaga, Juan-Luis; Martínez, Ignacio; Moggi-Cecchi, Jacopo

    2013-01-01

    The middle ear ossicles are only rarely preserved in fossil hominins. Here, we report the discovery of a complete ossicular chain (malleus, incus, and stapes) of Paranthropus robustus as well as additional ear ossicles from Australopithecus africanus. The malleus in both early hominin taxa is clearly human-like in the proportions of the manubrium and corpus, whereas the incus and stapes resemble African and Asian great apes more closely. A deep phylogenetic origin is proposed for the derived malleus morphology, and this may represent one of the earliest human-like features to appear in the fossil record. The anatomical differences found in the early hominin incus and stapes, along with other aspects of the outer, middle, and inner ear, are consistent with the suggestion of different auditory capacities in these early hominin taxa compared with modern humans. PMID:23671079

  18. Simulations and Measurements of Human Middle Ear Vibrations Using Multi-Body Systems and Laser-Doppler Vibrometry with the Floating Mass Transducer.

    PubMed

    Böhnke, Frank; Bretan, Theodor; Lehner, Stefan; Strenger, Tobias

    2013-10-22

    The transfer characteristic of the human middle ear with an applied middle ear implant (floating mass transducer) is examined computationally with a Multi-body System approach and compared with experimental results. For this purpose, the geometry of the middle ear was reconstructed from μ-computer tomography slice data and prepared for a Multi-body System simulation. The transfer function of the floating mass transducer, which is the ratio of the input voltage and the generated force, is derived based on a physical context. The numerical results obtained with the Multi-body System approach are compared with experimental results by Laser Doppler measurements of the stapes footplate velocities of five different specimens. Although slightly differing anatomical structures were used for the calculation and the measurement, a high correspondence with respect to the course of stapes footplate displacement along the frequency was found. Notably, a notch at frequencies just below 1 kHz occurred. Additionally, phase courses of stapes footplate displacements were determined computationally if possible and compared with experimental results. The examinations were undertaken to quantify stapes footplate displacements in the clinical practice of middle ear implants and, also, to develop fitting strategies on a physical basis for hearing impaired patients aided with middle ear implants.

  19. The effect of rocking stapes motions on the cochlear fluid flow and on the basilar membrane motion.

    PubMed

    Edom, Elisabeth; Obrist, Dominik; Henniger, Rolf; Kleiser, Leonhard; Sim, Jae Hoon; Huber, Alexander M

    2013-11-01

    The basilar membrane (BM) and perilymph motion in the cochlea due to rocking stapes motion (RSM) and piston-like stapes motion (PSM) is modeled by numerical simulations. The full Navier-Stokes equations are solved in a two-dimensional box geometry. The BM motion is modeled by independent oscillators using an immersed boundary technique. The traveling waves generated by both stimulation modes are studied. A comparison of the peak amplitudes of the BM motion is presented and their dependence on the frequency and on the model geometry (stapes position and cochlear channel height) is investigated. It is found that the peak amplitudes for the RSM are lower and decrease as frequency decreases whereas those for the PSM increase as frequency decreases. This scaling behavior can be explained by the different mechanisms that excite the membrane oscillation. Stimulation with both modes at the same time leads to either a slight increase or a slight decrease of the peak amplitudes compared to the pure PSM, depending on the phase shift between the two modes. While the BM motion is dominated by the PSM mode under normal conditions, the RSM may lead to hearing if no PSM is present or possible, e.g., due to round window atresia.

  20. Modeling microstructure of incudostapedial joint and the effect on cochlear input

    NASA Astrophysics Data System (ADS)

    Gan, Rong Z.; Wang, Xuelin

    2015-12-01

    The incudostapedial joint (ISJ) connects the incus to stapes in human ear and plays an important role for sound transmission from the tympanic membrane (TM) to cochlea. ISJ is a synovial joint composed of articular cartilage on the lenticular process and stapes head with the synovial fluid between them. However, there is no study on how the synovial ISJ affects the middle ear and cochlear functions. Recently, we have developed a 3-dimensinal finite element (FE) model of synovial ISJ and connected the model to our comprehensive FE model of the human ear. The motions of TM, stapes footplate, and basilar membrane and the pressures in scala vestibule and scala tympani were derived over frequencies and compared with experimental measurements. Results show that the synovial ISJ affects sound transmission into cochlea and the frequency-dependent viscoelastic behavior of ISJ provides protection for cochlea from high intensity sound.

  1. A Comparison Study of Partial Ossicular Reconstruction Prosthesis (PORP) Placement under the Malleus or Tympanic Membrane Graft in the Presence of the Malleus.

    PubMed

    Mutlu, Ahmet; Topdağ, Özlem; Topdağ, Murat; İşeri, Mete; Erdoğan, Selvet

    2017-08-01

    The aim of this study was to compare the hearing results of embedding the partial ossicular reconstruction prosthesis (PORP) underneath the malleus with the malleus relocation technique and tympanic membrane graft in the presence of the malleus. A retrospective review of patient charts and audiometric results in a tertiary referral center was conducted. In total, 83 patients who underwent intact canal tympanoplasty with mastoidectomy between 2010 and 2015 were included and divided into two different groups: malleus assembly to the stapes head (MASH) and tympanic membrane assembly to the stapes head (TASH). Pre- and postoperative audiometric results were assessed. The air-bone gap (ABG) and hearing gains were evaluated according to the groups. In MASH, 86.1% (n=31) of the patients were received successful surgery and the postoperative average ABG was 10.41 dB. In TASH, 82.9% (n=39) of the patients were considered successful and the postoperative ABG was 13.27 dB. According to the overall data, MASH was more statistically successful than TASH, and hearing gains at 500 Hz (p<0.036), 2000 Hz (p<0.031), and PTA (p<0.22) were statistically significant better in the MASH group. Malleus relocation is a successful technique with the presence of the malleus and provides better hearing outcomes than direct placement under the tympanomeatal flap. Both malleus- and tympanomeatal flap-linked groups were successful, but the malleus-linked group showed better ABGs.

  2. Further delineation of the GDF6 related multiple synostoses syndrome.

    PubMed

    Terhal, Paulien A; Verbeek, Nienke E; Knoers, Nine; Nievelstein, Rutger J A J; van den Ouweland, Ans; Sakkers, Ralph J; Speleman, Lucienne; van Haaften, Gijs

    2018-01-01

    A mutation in GDF6 was recently found to underlie a multiple synostoses syndrome. In this report, we describe the second family with GDF6-related multiple synostoses syndrome (SYNS4), caused by a novel c.1287C>A/p.Ser429Arg mutation in GDF6. In addition to synostoses of carpal and/or tarsal bones, at least 6 of 10 affected patients in this family have been diagnosed with mild to moderate hearing loss. In four of them otosclerosis was said to be present, one patient had hearing loss due to severe stapes fixation at the age of 6 years, providing evidence that hearing loss in the GDF6-related multiple synostoses syndrome can be present in childhood. Two others had surgery for stapes fixation at adult age. We hypothesize that, identical to the recently published GDF6-related multiple synostoses family, the p.Ser429Arg mutation also leads to a gain of function. The previously reported c.1330T>A/pTyr444Asn mutation was located in a predicted Noggin and receptor I interacting domain and the gain of function was partly due to resistance of the mutant GDF6 to the BMP-inhibitor Noggin. The results in our family show that mutations predicting to affect the type II receptor interface can lead to a similar phenotype and that otosclerosis presenting in childhood can be part of the GDF6-related multiple synostoses syndrome. © 2017 Wiley Periodicals, Inc.

  3. Development of wide-band middle ear transmission in the Mongolian gerbil

    NASA Astrophysics Data System (ADS)

    Overstreet, Edward H.; Ruggero, Mario A.

    2002-01-01

    Stapes vibrations were measured in deeply anesthetized adult and neonatal (ages: 14 to 20 days) Mongolian gerbils. In adult gerbils, the velocity magnitude of stapes responses to tones was approximately constant over the entire frequency range of measurements, 1 to 40 kHz. Response phases referred to pressure near the tympanic membrane varied approximately linearly as a function of increasing stimulus frequency, with a slope corresponding to a group delay of 30 μs. In neonatal gerbils, the sensitivity of stapes responses to tones was lower than in adults, especially at mid-frequencies (e.g., by about 15 dB at 10-20 kHz in gerbils aged 14 days). The input impedance of the adult gerbil cochlea, calculated from stapes vibrations and published measurements of pressure in scala vestibuli near the oval window [E. Olson, J. Acoust. Soc. Am. 103, 3445-3463 (1998)], is principally dissipative at frequencies lower than 10 kHz. Conclusions: (a) middle-ear vibrations in adult gerbils do not limit the input to the cochlea up to at least 40 kHz, i.e., within 0.5 oct of the high-frequency cutoff of the behavioral audiogram; and (b) the results in both adult and neonatal gerbils are inconsistent with the hypothesis that mass reactance controls high-frequency ossicular vibrations and support the idea that the middle ear functions as a transmission line.

  4. [The use of palisade technique in tympanoplasties after Heermann].

    PubMed

    Wielgosz, Romuald; Mroczkowski, Edward

    2006-01-01

    The palisade tympanoplasties-technique with using of tragal and conchal autografts for reconstruction of the tympanic membrane and the auditory canal wall was described. The operation started with the endaural incision. Tragal and conchal autograft palisade fragments with perichondrium for reconstruction of the tympanic membrane and the auditory canal wall have been used up to 1996 in 15,300 cases. We placed palisaded cartilage fragments parallel to the manubrium of the malleus in type I tympanoplasties and in type II or III procedures parallel to the long process of the incus. The "tunnel plasty" in the eustachian tubal entrance is performed with "simmering", "architrave" and "anti-architrave" to keep the tubal entrance open. This "tunnel plasty" results in a nice reconstruction of the tympano-meatal niche. The "annulus-stapes plate" in type III tympanoplasties replaces the function of the incus, crossing the promontory and reducing adhesions. This annulus-stapes bridge is fixed with a further palisade cartilage, "step plasty", which connects the "tunnel-plasty" with "annulus-stapes plate". The palisade-epitympanum-antrum plasty allows ventilation of the antrum via a tunnel constructed of well-fitting parallel pieces of cartilage fixed by self-tension (no glue) and replacing the bony canal wall. The "columella-tunnel plasty" has an L-shaped notch in the "annulus-stapes plate" fixing a columella of cartilage, placed in the oval window. Only in a case with a narrow oval window niche, a type IV palisade plasty can be performed or a prosthesis placed. The "annulus-stapes cartilage plate" is more stable reconstruction in type III tympanoplasties than are incus of foreign body interpositions. Adhesions on the promontory are found more often with fascia than with cartilage fragments. Histologic study of autograft cartilage showed good preservation of cartilage cells even 26 years after transplantation. The use of palisade cartilage technique brings very good functional and better long-term results.

  5. Fast Reverse Propagation of Sound in the Living Cochlea

    PubMed Central

    He, Wenxuan; Fridberger, Anders; Porsov, Edward; Ren, Tianying

    2010-01-01

    Abstract The auditory sensory organ, the cochlea, not only detects but also generates sounds. Such sounds, otoacoustic emissions, are widely used for diagnosis of hearing disorders and to estimate cochlear nonlinearity. However, the fundamental question of how the otoacoustic emission exits the cochlea remains unanswered. In this study, emissions were provoked by two tones with a constant frequency ratio, and measured as vibrations at the basilar membrane and at the stapes, and as sound pressure in the ear canal. The propagation direction and delay of the emission were determined by measuring the phase difference between basilar membrane and stapes vibrations. These measurements show that cochlea-generated sound arrives at the stapes earlier than at the measured basilar membrane location. Data also show that basilar membrane vibration at the emission frequency is similar to that evoked by external tones. These results conflict with the backward-traveling-wave theory and suggest that at low and intermediate sound levels, the emission exits the cochlea predominantly through the cochlear fluids. PMID:20513393

  6. Absence of Measles Virus Detection from Stapes of Patients with Otosclerosis.

    PubMed

    Flores-García, María de Lourdes; Colín-Castro, Claudia Adriana; Hernández-Palestina, Mario Sabas; Sánchez-Larios, Roberto; Franco-Cendejas, Rafael

    2018-01-01

    Objective To determine molecularly the presence of measles virus genetic material in the stapes of patients with otosclerosis. Study Design A cross-sectional study. Setting A tertiary referral hospital. Subjects and Methods Genetic material was extracted from the stapes of patients with otosclerosis (n = 93) during the period from March 2011 to April 2012. The presence of viral measles sequences was evaluated by the real-time reverse transcriptase polymerase chain reaction (RT-PCR). The expression of the CD46 gene was determined. Results Ninety-three patients were included in the study. No sample was positive for any of 3 measles virus genes (H, N, and F). Measles virus RNA was not detected in any sample by real-time RT-PCR. CD46 levels were positive in 3.3% (n = 3) and negative in 96.7% (n = 90). Conclusion This study does not support the theory of measles virus as the cause of otosclerosis. It is necessary to do more research about other causal theories to clarify its etiology and prevention.

  7. Optical Coherence Tomography of the Tympanic Membrane and Middle Ear: A Review.

    PubMed

    Tan, Hsern Ern Ivan; Santa Maria, Peter Luke; Wijesinghe, Philip; Francis Kennedy, Brendan; Allardyce, Benjamin James; Eikelboom, Robert Henry; Atlas, Marcus David; Dilley, Rodney James

    2018-05-01

    Objective To evaluate the recent developments in optical coherence tomography (OCT) for tympanic membrane (TM) and middle ear (ME) imaging and to identify what further development is required for the technology to be integrated into common clinical use. Data Sources PubMed, Embase, Google Scholar, Scopus, and Web of Science. Review Methods A comprehensive literature search was performed for English language articles published from January 1966 to January 2018 with the keywords "tympanic membrane or middle ear,"optical coherence tomography," and "imaging." Conclusion Conventional imaging techniques cannot adequately resolve the microscale features of TM and ME, sometimes necessitating diagnostic exploratory surgery in challenging otologic pathology. As a high-resolution noninvasive imaging technique, OCT offers promise as a diagnostic aid for otologic conditions, such as otitis media, cholesteatoma, and conductive hearing loss. Using OCT vibrometry to image the nanoscale vibrations of the TM and ME as they conduct acoustic waves may detect the location of ossicular chain dysfunction and differentiate between stapes fixation and incus-stapes discontinuity. The capacity of OCT to image depth and thickness at high resolution allows 3-dimensional volumetric reconstruction of the ME and has potential use for reconstructive tympanoplasty planning and the follow-up of ossicular prostheses. Implications for Practice To achieve common clinical use beyond these initial discoveries, future in vivo imaging devices must feature low-cost probe or endoscopic designs and faster imaging speeds and demonstrate superior diagnostic utility to computed tomography and magnetic resonance imaging. While such technology has been available for OCT, its translation requires focused development through a close collaboration between engineers and clinicians.

  8. [Destruction of microsurgical devices by sterilisation].

    PubMed

    Berto, Raphaela; Strutz, Jürgen

    2017-11-01

    Hospital facilities issue numerous risk announcements on corrosion, deformation or premature wearout of medical devices every year. As there is yet little data on the impact of reprocessing on the quality and durability of microsurgical instruments, this paper aims at evaluating the effects of the reprocessing on microsurgical instruments. Material and Methods 22 brand new microsurgical instruments for stapes surgery were being reprocessed 30 times without being used for surgery or other purposes in the interim time. After each reprocessing the instruments were examined macroscopicly and microscopicly. The results were portrayed in a photo documentation and analysed on that basis. Results Almost all devices showed mechanical damage caused by the reprocessing procedure. The increasing deterioration was often associated with missing protective caps. Furthermore contaminations and stains were apparent in several cases. Conclusions The findings illustrate that careful handling of delicate surgical devices during reprocessing is vital. They also highlight problems of protective caps. As an alternative going forward it should be considered to store microsurgical instruments statically in special racks. Georg Thieme Verlag KG Stuttgart · New York.

  9. Dizziness, malpractice, and the otolaryngologist.

    PubMed

    Tolisano, Anthony M; Song, Sungjin A; Ruhl, Douglas S; Littlefield, Philip D

    To assess malpractice claims related to the management of dizziness in otolaryngology in order to improve care and minimize the risk of litigation. This is a retrospective review of the LexisNexis "Jury Verdicts and Settlements" database. All lawsuits and out of court adjudications related to the management of dizziness by otolaryngologists were collected. Data including patient demographics, plaintiff allegation, procedure performed, and indemnities were analyzed. Of 21 cases meeting inclusion criteria, 17 were decided by a trial jury and four were resolved out of court. Jury verdicts favored the plaintiff 53% of the time and a payout was made in 57% of cases overall. Average payments were higher for jury verdicts in favor of the plaintiff ($1.8 million) as compared to out of court settlements ($545,000). Two-thirds of cases involved surgery, most commonly stapes surgery. Legal allegations, including physical injury, negligence, and lack of informed consent failed to predict the legal outcome. Appropriate examination, testing, and referrals within a timely manner are crucial in the management of dizzy patients to avoid misdiagnoses. It is imperative that patients undergoing ear surgery are appropriately counseled that dizziness is a potential complication. The analysis of malpractice literature is complementary to clinical studies, with the potential to educate practitioners, improve patient care, and mitigate risk. Published by Elsevier Inc.

  10. Bone conduction responses of middle ear structures in Thiel embalmed heads

    NASA Astrophysics Data System (ADS)

    Arnold, Andreas; Stieger, Christof; Caversaccio, Marco; Kompis, Martin; Guignard, Jérémie

    2015-12-01

    Thiel-embalmed human whole-head specimens offer a promising alternative model for bone conduction (BC) studies of middle ear structures. In this work we present the Thiel model's linearity and stability over time as well as its possible use in the study of a fixed ossicle chain. Using laser Doppler vibrometry (LDV), the motion of the retroauricular skull, the promontory, the stapes footplate and the round window (RW) were measured. A bone-anchored hearing aid stimulated the ears with step sinus tones logarithmically spread between 0.1 and 10 kHz. Linearity of the model was verified using input levels in steps of 10 dBV. The stability of the Thiel model over time was examined with measurements repeated after hours and weeks. The influence of a cement-fixed stapes was assessed. The middle ear elements measured responded linearly in amplitude for the applied input levels (100, 32.6, and 10 mV). The variability of measurements for both short- (2 h) and long-term (4-16 weeks) repetitions in the same ear was lower than the interindividual difference. The fixation of the stapes induced a lowered RW displacement for frequencies near 750 Hz (-4 dB) and an increased displacement for frequencies above 1 kHz (max. +3.7 dB at 4 kHz). LDV assessment of BC-induced middle ear motion in Thiel heads can be performed with stable results. The vibratory RW response is affected by the fixation of the stapes, indicating a measurable effect of ossicle chain inertia on BC response in Thiel embalmed heads.

  11. Middle ear bones of a mid-gestation ruminant foetus extracted from x-ray computed tomography

    NASA Astrophysics Data System (ADS)

    Costeur, Loic; Mennecart, Bastien; Müller, Bert; Schulz, Georg

    2016-10-01

    The timing of ossification of middle ear ossicles has been extensively studied in humans. This is an exception since it is vastly unknown in the +5000 extant species of placentals. As a preliminary approach, a cow foetus (around 115 days of gestation) was visualized using X-ray microtomography (μCT) and the ossicles including stapes, incus, and malleus could be extracted from the data set. All three bones have already undergone substantial ossification, which allow comparison to adult middle ear bones. Their ossification at this stage parallels ossification in humans at a comparable stage of gestation. While full ossification is not yet achieved almost all the morphological characters of the ossicles are observed. Bone tissue is still very porous, the stapes does not have the characteristic plate-like footplate, the lenticular process of the incus is missing and the manubrium of the malleus is very thin and not yet complete. Despite all this, the ossicles are articulate with each other and perfectly with the bony labyrinth. The stapes footplate is positioned on the oval window but is smaller than the latter while it should perfectly fit to transmit sound vibrations to the cochlea. All ossicles, especially the stapes, have not yet reached adult size, while the bony labyrinth already has. This is the first detailed description of a set of middle ear bones in a placental at mid-gestation based on high-resolution μCT. Similarities in ossification timing with humans encourage more work to be done on foetuses to understand if a general rule for placental mammals exists.

  12. Assessing stapes piston position using computed tomography: a cadaveric study.

    PubMed

    Hahn, Yoav; Diaz, Rodney; Hartman, Jonathan; Bobinski, Matthew; Brodie, Hilary

    2009-02-01

    Temporal bone computed tomographic (CT) scanning in the postoperative stapedotomy patient is inaccurate in assessing stapes piston position within the vestibule. Poststapedotomy patients that have persistent vertigo may undergo CT scanning to assess the position of the stapes piston within the vestibule to rule out overly deep insertion. Vertigo is a recognized complication of the deep piston, and CT evaluation is often recommended. The accuracy of CT scan in this setting is unestablished. Stapedotomy was performed on 12 cadaver ears, and stainless steel McGee pistons were placed. The cadaver heads were then scanned using a fine-cut temporal bone protocol. Temporal bone dissection was performed with microscopic measurement of the piston depth in the vestibule. These values were compared with depth of intravestibular penetration measured on CT scan by 4 independent measurements. The intravestibular penetration as assessed by computed tomography was consistently greater than the value found on cadaveric anatomic dissection. The radiographic bias was greater when piston location within the vestibule was shallower. The axial CT scan measurement was 0.53 mm greater, on average, than the anatomic measurement. On average, the coronal CT measurement was 0.68 mm greater than the anatomic measurement. The degree of overestimation of penetration, however, was highly inconsistent. Standard temporal bone CT scan is neither an accurate nor precise examination of stapes piston depth within the vestibule. We found that CT measurement consistently overstated intravestibular piston depth. Computed tomography is not a useful study in the evaluation of piston depth for poststapedectomy vertigo and is of limited value in this setting.

  13. On the Coupling Between the Incus and the Stapes in the Cat

    PubMed Central

    Heng Siah, T.; McKee, Marc D.; Daniel, Sam J.; Decraemer, Willem F.

    2005-01-01

    The connection between the long process and the lenticular process of the incus is extremely fine, so much so that some authors have treated the lenticular process as a separate bone. We review descriptions of the lenticular process that have appeared in the literature, and present some new histological observations. We discuss the dimensions and composition of the lenticular process and of the incudostapedial joint, and present estimates of the material properties for the bone, cartilage, and ligament of which they are composed. We present a preliminary finite-element model which includes the lenticular plate, the bony pedicle connecting the lenticular plate to the long process, the head of the stapes, and the incudostapedial joint. The model has a much simplified geometry. We present simulation results for ranges of values for the material properties. We then present simulation results for this model when it is incorporated into an overall model of the middle ear of the cat. For the geometries and material properties used here, the bony pedicle is found to contribute significant flexibility to the coupling between the incus and the stapes. PMID:15735938

  14. A micropower miniature piezoelectric actuator for implantable middle ear hearing device.

    PubMed

    Wang, Zhigang; Mills, Robert; Luo, Hongyan; Zheng, Xiaolin; Hou, Wensheng; Wang, Lijun; Brown, Stuart I; Cuschieri, Alfred

    2011-02-01

    This paper describes the design and development of a small actuator using a miniature piezoelectric stack and a flextensional mechanical amplification structure for an implantable middle ear hearing device (IMEHD). A finite-element method was used in the actuator design. Actuator vibration displacement was measured using a laser vibrometer. Preliminary evaluation of the actuator for an IMEHD was conducted using a temporal bone model. Initial results from one temporal bone study indicated that the actuator was small enough to be implanted within the middle ear cavity, and sufficient stapes displacement can be generated for patients with mild to moderate hearing losses, especially at higher frequency range, by the actuator suspended onto the stapes. There was an insignificant mass-loading effect on normal sound transmission (<3 dB) when the actuator was attached to the stapes and switched off. Improved vibration performance is predicted by more firm attachment. The actuator power consumption and its generated equivalent sound pressure level are also discussed. In conclusion, the actuator has advantages of small size, lightweight, and micropower consumption for potential use as IMHEDs.

  15. Laser-assisted fixation of a nitinol stapes prosthesis.

    PubMed

    Schrötzlmair, Florian; Suchan, Fabian; Pongratz, Thomas; Krause, Eike; Müller, Joachim; Sroka, Ronald

    2018-02-01

    Otosclerosis is an inner ear bone disease characterized by fixation of the stapes and consequently progressive hearing loss. One treatment option is the surgical replacement of the stapes by a prosthesis. When so called "smart materials" like nitinol are used, prosthesis fixation can be performed using a laser without manual crimping on the incus. However, specific laser-prosthesis interactions have not been described yet. The aim of the present study was to elucidate the thermo-mechanical properties of the NiTiBOND® prosthesis as a basis for handling instructions for laser-assisted prosthesis fixation. Closure of the NiTiBOND® prosthesis was induced ex vivo by either a diode laser emitting at λ = 940 nm or a CO 2 laser (λ = 10,600 nm). Total energy for closure was determined. Suitable laser parameters (pulse duration, power per pulse, distance between tip of the laser fiber and prosthesis) were assessed. Specific laser-prosthesis interactions were recorded. Especially the diode laser was found to be an appropriate energy source. A total energy deposit of 60 mJ by pulses in near contact application was found to be sufficient for prosthesis closure ex vivo. Energy should be transmitted through a laser fiber equipollent to the prosthesis band diameter. Specific deformation characteristics due to the zonal prosthesis composition have to be taken into account. NiTiBOND® stapes prosthesis can be closed by very little energy when appropriate energy sources like diode lasers are used, suggesting a relatively safe application in vivo. Lasers Surg. Med. 50:153-157, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  16. Scala vestibuli pressure and three-dimensional stapes velocity measured in direct succession in gerbil.

    PubMed

    Decraemer, W F; de La Rochefoucauld, O; Dong, W; Khanna, S M; Dirckx, J J J; Olson, E S

    2007-05-01

    It was shown that the mode of vibration of the stapes has a predominant piston component but rotations producing tilt of the footplate are also present. Tilt and piston components vary with frequency. Separately it was shown that the pressure gain between ear canal and scala vestibuli was a remarkably flat and smooth function of frequency. Is tilt functional contributing to the pressure in the scala vestibuli and helping in smoothing the pressure gain? In experiments on gerbil the pressure in the scala vestibuli directly behind the footplate was measured while recording simultaneously the pressure produced by the sound source in the ear canal. Successively the three-dimensional motion of the stapes was measured in the same animal. Combining the vibration measurements with an anatomical shape measurement from a micro-CT (CT: computed tomography) scan the piston-like motion and the tilt of the footplate was calculated and correlated to the corresponding scala vestibuli pressure curves. No evidence was found for the hypothesis that dips in the piston velocity are filled by peaks in tilt in a systematic way to produce a smooth middle ear pressure gain function. The present data allowed calculations of the individual cochlear input impedances.

  17. Middle ear function and cochlear input impedance in chinchilla

    PubMed Central

    Slama, Michaël C. C.; Ravicz, Michael E.; Rosowski, John J.

    2010-01-01

    Simultaneous measurements of middle ear-conducted sound pressure in the cochlear vestibule PV and stapes velocity VS have been performed in only a few individuals from a few mammalian species. In this paper, simultaneous measurements of PV and VS in six chinchillas are reported, enabling computation of the middle ear pressure gain GME (ratio of PV to the sound pressure in the ear canal PTM), the stapes velocity transfer function SVTF (ratio of the product of VS and area of the stapes footplate AFP to PTM), and, for the first time, the cochlear input impedance ZC (ratio of PV to the product of VS and AFP) in individuals. |GME| ranged from 25 to 35 dB over 125 Hz–8 kHz; the average group delay between 200 Hz and 10 kHz was about 52 μs. SVTF was comparable to that of previous studies. ZC was resistive from the lowest frequencies up to at least 10 kHz, with a magnitude on the order of 1011 acoustic ohms. PV, VS, and the acoustic power entering the cochlea were good predictors of the shape of the audiogram at frequencies between 125 Hz and 2 kHz. PMID:20329840

  18. How is sound conducted to the cochlea in toothed whales?

    NASA Astrophysics Data System (ADS)

    Zosuls, Aleks; Mountain, David C.; Ketten, Darlene R.

    2015-12-01

    Toothed whales (Odontocetes) typically have small occluded ear canals and sea water has a characteristic impedance that is much more similar to the impedance of soft tissues of the head than is the case for the air-tissue interface in terrestrial mammals. This makes it plausible that significant acoustic energy is being transmitted to their middle ear by tissue conduction. In addition, some authors have proposed that sound reaches the cochlea via bone conduction rather than via the tympanic membrane. To address these issues, we have developed a method to measure stapes velocity in response to vibrational stimulation at arbitrary locations on heads and ears harvested from stranded animals. Stapes velocity was measured with a Laser Doppler Velocimeter at the footplate with the cochlea drained. In all species tested, the transfer function of stapes velocity referenced to actuator velocity showed a high-pass characteristic. The corner frequency varied with species and experiment between 4 kHz and 60 kHz. This is similar to what is seen in odontocete audiograms but the cutoff slope is typically steeper than in the audiograms. There was no indication of high frequency cutoff within our measurement range. Disrupting the ossicles and fat bodies affected the transfer functions.

  19. Stapes Displacement and Intracochlear Pressure in Response to Very High Level, Low Frequency Sounds

    PubMed Central

    Greene, Nathaniel T.; Jenkins, Herman A.; Tollin, Daniel J.; Easter, James R.

    2018-01-01

    The stapes is held in the oval window by the stapedial annular ligament (SAL), which restricts total peak-to-peak displacement of the stapes. Previous studies have suggested that for moderate (< 130 dB SPL) sound levels intracochlear pressure (PIC), measured at the base of the cochlea far from the basilar membrane, increases directly proportionally with stapes displacement (DStap), thus a current model of impulse noise exposure (the Auditory Hazard Assessment Algorithm for Humans, or AHAAH) predicts that peak PIC will vary linearly with DStap up to some saturation point. However, no direct tests of DStap, or of the relationship with PIC during such motion, have been performed during acoustic stimulation of the human ear. In order to examine the relationship between DStap and PIC to very high level sounds, measurements of DStap and PIC were made in cadaveric human temporal bones. Specimens were prepared by mastoidectomy and extended facial recess to expose the ossicular chain. Measurements of PIC were made in scala vestibuli (PSV) and scala tympani (PST), along with the SPL in the external auditory canal (PEAC), concurrently with laser Doppler vibrometry (LDV) measurements of stapes velocity (VStap). Stimuli were moderate (~100 dB SPL) to very high level (up to ~170 dB SPL), low frequency tones (20–2560 Hz). Both DStap and PSV increased proportionally with sound pressure level in the ear canal up to approximately ~150 dB SPL, above which both DStap and PSV showed a distinct deviation from proportionality with PEAC. Both DStap and PSV approached saturation: DStap at a value exceeding 150 μm, which is substantially higher than has been reported for small mammals, while PSV showed substantial frequency dependence in the saturation point. The relationship between PSV and DStap remained constant, and cochlear input impedance did not vary across the levels tested, consistent with prior measurements at lower sound levels. These results suggest that PSV sound pressure holds constant relationship with DStap, described by the cochlear input impedance, at these, but perhaps not higher, stimulation levels. Additionally, these results indicate that the AHAAH model, which was developed using results from small animals, underestimates the sound pressure levels in the cochlea in response to high level sound stimulation, and must be revised. PMID:28189837

  20. Incus replacement prostheses of hydroxylapatite in middle ear reconstruction.

    PubMed

    Wehrs, R E

    1989-05-01

    Hydroxylapatite is a calcium bioceramic that has the same chemical composition as living bone, Ca10 (PO4) 6 (OH) 2. Since 1970 it has been used as a material in reconstructive prostheses and augmentation of lost tissues in various surgical specialties including maxillofacial surgery, plastic surgery, otolaryngology, and orthopedics. For over 20 years the author has used autograft and homograft ossicles in tympanoplasty. These incudi have been modified into prostheses that were utilized in ossicular reconstruction. During this time two principle prostheses have evolved, the notched incus with short and long processes. The short process prosthesis is used with an intact stapes, whereas the notched incus with long process carries the sound pressure directly to the stapedial footplate. These prostheses have been successful in improving and maintaining hearing following tympanoplasty. Unfortunately, however, the use of human tissue has certain limitations: it is not readily accessible and has a limited shelf life. Furthermore, clinicians are wary of using homograft tissue as concern over the AIDS virus spreads. Therefore it was felt prudent to develop a manmade prosthesis that would as nearly as possible match the advantages of living bone. Hydroxylapetite most nearly met those qualifications.

  1. Posterior semicircular canal dehiscence: value of VEMP and multidetector CT.

    PubMed

    Vanspauwen, R; Salembier, L; Van den Hauwe, L; Parizel, P; Wuyts, F L; Van de Heyning, P H

    2006-01-01

    To illustrate that posterior semicircular canal dehiscence can present similarly to superior semicircular canal dehiscence. The symptomatology initially presented as probable Menière's disease evolving into a mixed conductive hearing loss with a Carhart notch-type perceptive component suggestive of otosclerosis-type stapes fixation. A small hole stapedotomy resulted in a dead ear and a horizontal semicircular canal hypofunction. Recurrent incapacitating vertigo attacks developed. Vestibular evoked myogenic potential (VEMP) testing demonstrated intact vestibulocollic reflexes. Additional evaluation with high resolution multidetector computed tomography (MDCT) of the temporal bone showed a dehiscence of the left posterior semicircular canal. Besides superior semicircular canal dehiscence, posterior semicircular canal dehiscence has to be included in the differential diagnosis of atypical Menière's disease and/or low tone conductive hearing loss. The value of performing MDCT before otosclerosis-type surgery is stressed. VEMP might contribute to establishing the differential diagnosis.

  2. [The length of the piston in otosclerosis surgery].

    PubMed

    Portmann, D; Alcantara, M; Vianna, M

    2007-01-01

    The measurement of the piston is always described as a significant stage of the surgery but its length is never clearly defined. The goal of this work is to determine the length of the prosthesis. From May 2003 to May 2005, 128 patients with otosclerosis, diagnosed on the basis of their clinical history and their audiogram, were included in this prospective study. Some of them were revision surgeries. The prosthesis generally used was the Portmann piston clip (Medtronic Xomed Inc Portmann Piston Clip Stainless Steel/Fluoroplastic). In stapedectomies, a Teflon piston of 0.6 mm of diameter was used (Pouret Company Fluoroplastic Stapes Prosthesis). These prostheses must be trimmed before their installation. The measurement technique is described. The length of the prosthesis was increased by 0.5 mm to include the thickness of the footplate. The Portmann piston clip was used 116 times (100 initial surgeries and 16 revisions surgeries) and the Teflon prosthesis of 0.6 mm of diameter only 13 times (6 primary stapedectomies and 7 revisions stapedectomies). The length of the prosthesis was between 3,5 mm and 5 mm. In the majority of cases, the length of the prosthesis was 4.75 mm (62 patients, 48.1%), followed by 4.5 mm (29 patients, 22.5%) and 5 mm (27 patients, 20.9%). In eleven cases (8.5%) the prosthesis measured less than 4,5 mm. None of the patients in this study experienced a postoperative sensorineural hearing loss. The measurement of the length of the piston is very significant, and in our study the majority of the pistons were cut at 4.75 mm which indicates an incus-footplate measurement of 4.25 mm.

  3. Congenital stapes malformation: Rare conductive hearing loss in a patient with Waardenburg syndrome.

    PubMed

    Melzer, Jonathan M; Eliason, Michael; Conley, George S

    2016-04-01

    Waardenburg syndrome is a known autosomal dominant cause of congenital hearing loss. It is characterized by a distinctive phenotypic appearance and often involves sensorineural hearing loss. Temporal bone abnormalities and inner ear dysmorphisms have been described in association with the disease. However, middle ear abnormalities as causes of conductive hearing loss are not typically seen in Waardenburg syndrome. We discuss a case of an 8-year-old female who meets diagnostic criteria for Waardenburg syndrome type 3 and who presented with a bilateral conductive hearing loss associated with congenital stapes fixation. We discuss management strategy in this previously unreported phenotype. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.

  4. Fixation and detachment of superior and anterior malleolar ligaments in human middle ear: Experiment and modeling

    PubMed Central

    Dai, Chenkai; Cheng, Tao; Wood, Mark W.; Gan, Rong Z.

    2007-01-01

    The aim of this study is to investigate the function of the superior malleolar ligament (SML) and the anterior malleolar ligament (AML) in human middle ear for sound transmission through simulations of fixation and detachment of these ligaments in human temporal bones and a finite element (FE) ear model. Two laser vibrometers were used to measure the vibrations of the tympanic membrane (TM) and stapes footplate. A 3-D FE ear model was used to predict the transfer function of the middle ear with ligament fixation and detachment. The results demonstrate that fixations and detachments of the SML and AML had different effects on TM and stapes footplate movements. Fixation of the SML resulted in a reduction of displacement of the TM (umbo) and the footplate at low frequencies (f < 1000 Hz), but also caused a shift of displacement peak to higher frequencies. Fixation of both SML and AML caused a reduction of 15 dB at umbo or stapes at low frequencies. Detachment of the SML had almost no effect on TM and footplate mobility, but AML detachment had a minor effect on TM and footplate movement. The FE model was able to predict the effects of SML and AML fixation and detachment. PMID:17517484

  5. The effect of round window reinforcement on human hearing

    NASA Astrophysics Data System (ADS)

    Guan, Xiying; Cheng, Y. Song; Galaiya, Deepa; Nakajima, Hideko H.

    2018-05-01

    The compliant round window (RW) allows volume velocity to flow within the incompressible fluid of the cochlea as the oval window vibrates during sound stimulation. Recently, surgically stiffened RW is emerging as a treatment for various conditions such as superior canal dehiscence and hyperacusis. However, we lack the basic understanding of how reinforcing the RW affects sound transmission in the ear. The aim of this study is to clarify the effect of RW reinforcement on hearing. To study the effect of RW reinforcement with tissue and adhesive, we measured intracochlear pressures in scala vestibuli (Psv) and scala tympani (Pst) at the cochlear base together with stapes velocity in response to sound at the ear canal. The cochlear input drive (Pdiff = Psv - Pst, an estimate of hearing) was determined before and after RW reinforcement in a fresh human cadaveric ear. Results show that increasing the RW stiffness by reinforcement can affect the cochlear input drive in unexpected ways. Below 200 Hz, RW reinforcement resulted in reduced stapes motion, however an increase in cochlear drive, consistent with increase in hearing. At 200-1000 Hz, the hearing and stapes motion both were slightly decreased. Reinforcing the RW had no effect above 1 kHz. To understand the cochlear mechanical effects of RW reinforcement, we used a lumped-element model that simulated our findings.

  6. A dynamic and harmonic damped finite element analysis model of stapedotomy.

    PubMed

    Blayney, A W; Williams, K R; Rice, H J

    1997-03-01

    This study was undertaken in an attempt to better understand the mechanics of sound transmission at the footplate following stapedotomy. The insertion of a Teflon (polytetrafluoroethylene) stapes prosthesis introduces new constraints within the reconstructed ossicular chain which have an effect on the normal vibration patterns of the tympanic membrane. In a finite element model of the ear, constraints have been reproduced as a series of spring constants in the incus/prosthesis/footplate interfaces incorporating damping to simulate the impedance of the inner ear. At zero damping, the frequency response at the pseudo stapes footplate exhibit several maxima and minima between 800 Hz and 2.5 Hz. At higher damping values, these maxima and minima become smoothened out with two or three naturals occurring over the same frequency range. Severe ankylosis of a diseased footplate is reproduced by over-damped conditions. The umbo, incus and stapes footplate vibrate in phase with similar frequencies at light damping levels. The movement of the prosthesis at the pseudo-footplate can be large in the out of plane axis of the ossicular chain, unless sufficient support is provided at the reconstructed footplate. Clinically, this would suggest the vein graft interposed between the piston and stapedotomy hole should endow resistance and elasticity to the system.

  7. Reassessment of the La Ferrassie 3 Neandertal ossicular chain.

    PubMed

    Quam, Rolf; Martínez, Ignacio; Arsuaga, Juan Luis

    2013-04-01

    The ossicular chain in La Ferrassie 3 was briefly described in the monograph on the La Ferrassie Neandertal children, but to date has not been the subject of detailed study. We provide new data on these important fossils and re-examine some previous suggestions of derived Neandertal features in the middle ear ossicles based on more limited evidence. The malleus shows a curved lateral margin of the manubrium and a relatively large head. The incus shows a tall articular facet, a depressed area on the medial surface of the body, a straight anterior border of the long process and a more closed angle between the processes. The stapes shows an asymmetrical configuration of the crura, with an anteriorly skewed head, and generally small dimensions, including a smaller and relatively wider stapedial footplate. These same features can also be seen in the few other Neandertal ear ossicles known, suggesting that a consistent anatomical pattern characterizes the Neandertal ossicular chain. While the phylogenetic polarity of many of these features remains to be clarified, the asymmetrical stapes and anteriorly skewed stapedial head appear to be derived Neandertal features. In addition, while the larger malleus head and incus articular facet in La Ferrassie 3 might reflect larger body mass in Neandertals, the larger stapes footplates in Homo sapiens cannot be explained by changes in body mass. Indeed, H. sapiens seems to depart from the general mammalian pattern in combining an increase in stapes footplate size with a decrease in body mass. Although the malleus/incus lever ratio in La Ferrassie 3 is similar to that in H. sapiens, Neandertals appear to be characterized by a slightly different spatial relationship and articulation of the ossicular chain within the tympanic cavity. While only limited inferences can be drawn regarding hearing ability based on the ossicles, the few physiologically relevant dimensions in the La Ferrassie 3 ear bones are similar to H. sapiens. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. Stapes displacement and intracochlear pressure in response to very high level, low frequency sounds.

    PubMed

    Greene, Nathaniel T; Jenkins, Herman A; Tollin, Daniel J; Easter, James R

    2017-05-01

    The stapes is held in the oval window by the stapedial annular ligament (SAL), which restricts total peak-to-peak displacement of the stapes. Previous studies have suggested that for moderate (<130 dB SPL) sound levels intracochlear pressure (P IC ), measured at the base of the cochlea far from the basilar membrane, increases directly proportionally with stapes displacement (D Stap ), thus a current model of impulse noise exposure (the Auditory Hazard Assessment Algorithm for Humans, or AHAAH) predicts that peak P IC will vary linearly with D Stap up to some saturation point. However, no direct tests of D Stap , or of the relationship with P IC during such motion, have been performed during acoustic stimulation of the human ear. In order to examine the relationship between D Stap and P IC to very high level sounds, measurements of D Stap and P IC were made in cadaveric human temporal bones. Specimens were prepared by mastoidectomy and extended facial recess to expose the ossicular chain. Measurements of P IC were made in scala vestibuli (P SV ) and scala tympani (P ST ), along with the SPL in the external auditory canal (P EAC ), concurrently with laser Doppler vibrometry (LDV) measurements of stapes velocity (V Stap ). Stimuli were moderate (∼100 dB SPL) to very high level (up to ∼170 dB SPL), low frequency tones (20-2560 Hz). Both D Stap and P SV increased proportionally with sound pressure level in the ear canal up to approximately ∼150 dB SPL, above which both D Stap and P SV showed a distinct deviation from proportionality with P EAC . Both D Stap and P SV approached saturation: D Stap at a value exceeding 150 μm, which is substantially higher than has been reported for small mammals, while P SV showed substantial frequency dependence in the saturation point. The relationship between P SV and D Stap remained constant, and cochlear input impedance did not vary across the levels tested, consistent with prior measurements at lower sound levels. These results suggest that P SV sound pressure holds constant relationship with D Stap , described by the cochlear input impedance, at these, but perhaps not higher, stimulation levels. Additionally, these results indicate that the AHAAH model, which was developed using results from small animals, underestimates the sound pressure levels in the cochlea in response to high level sound stimulation, and must be revised. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Review of a single surgeon's stapedotomy cases performed with a nickel titanium prosthesis over a 14-year period.

    PubMed

    Justicz, Natalie; Strickland, Kaitlyn F; Motamedi, Kevin K; Mattox, Douglas E

    2017-04-01

    Stapes surgery with a nickel titanium prosthesis is a safe and well-tolerated procedure that leads to a significant improvement in hearing outcomes. To identify the efficacy and safety of stapedotomy procedures performed with a nickel titanium prosthesis for patients with otosclerosis. A review of 431 unique stapedotomies performed over 14 years by a single surgeon at an academic tertiary care center yielded 312 cases with nickel titanium prosthesis that met inclusion criteria of otosclerosis diagnosis, initial surgery in operative ear, and presence of pre-operative and post-operative audiograms. Pure-tone averages (PTA) at baseline and 8 weeks after surgery were calculated over four frequencies; 0.5, 1, 2, and 4 kHz. Average air-bone gaps (ABG) were calculated from pre-operative and post-operative audiograms. Average pre-operative baseline PTA was 56.7 dB in the affected ear. Post-operative PTA was 30.1 dB, a 26.6 dB improvement. Initial average ABG was 29.7 dB, while post-operative ABG averaged 5.4 dB, a 24.2 dB improvement. Surgical success (closure of ABG within 10 dB) was achieved in 263 (84%) patients. Rate of surgical success was not correlated with age, gender, race, or affected ear. Complications included recurrent conductive hearing loss (14), progressive SNHL (4), and post-operative BPPV (3).

  10. A case of chronic otitis media caused by Mycobacterium abscessus.

    PubMed

    Sugimoto, Hisashi; Ito, Makoto; Hatano, Miyako; Nakanishi, Yosuke; Maruyama, Yumiko; Yoshizaki, Tomokazu

    2010-10-01

    Although it appears very uncommon in adult COM, Mycobacterium abscessus should be considered as a possible cause of a chronically draining ear. Multi-antibiotic chemotherapy including high-dose clarithromycin can effectively treat adult COM cased by M. abscessus. The first case report of adult chronic otitis media (COM) caused by M. abscessus is described here. A 61-year-old woman presented persistent otorrhea for 2 months, despite treatment with standard antimicrobial drugs. Physical examination revealed a small perforation of the tympanic membrane and edematous middle ear mucosa. Mycobacterial cultures and PCR yielded non-tuberculous mycobacteria (NTM); M. abscessus. Intravenous panipenem/betamipron and amikacin and oral clarithromycin were administered for 36 days. Computed tomography of the temporal bone showed improved aeration in the tympanic cavity, but soft tissue shadow remained unchanged in the mastoid 31 days after starting medication. She therefore underwent tympano-mastoidectomy at 36 days. At surgery, inflammation remained in the middle ear, and edematous pale mucosal tissue was noted around the stapes and ossicular chain. Histopathologic examination showed inflammation and granulation tissue, but no caseating necrosis or acid-fast bacilli. After surgery the symptoms resolved and remained well without evidence of infection recurrence 12 months after the operation. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.

  11. Gerbil middle-ear sound transmission from 100 Hz to 60 kHz1

    PubMed Central

    Ravicz, Michael E.; Cooper, Nigel P.; Rosowski, John J.

    2008-01-01

    Middle-ear sound transmission was evaluated as the middle-ear transfer admittance HMY (the ratio of stapes velocity to ear-canal sound pressure near the umbo) in gerbils during closed-field sound stimulation at frequencies from 0.1 to 60 kHz, a range that spans the gerbil’s audiometric range. Similar measurements were performed in two laboratories. The HMY magnitude (a) increased with frequency below 1 kHz, (b) remained approximately constant with frequency from 5 to 35 kHz, and (c) decreased substantially from 35 to 50 kHz. The HMY phase increased linearly with frequency from 5 to 35 kHz, consistent with a 20–29 μs delay, and flattened at higher frequencies. Measurements from different directions showed that stapes motion is predominantly pistonlike except in a narrow frequency band around 10 kHz. Cochlear input impedance was estimated from HMY and previously-measured cochlear sound pressure. Results do not support the idea that the middle ear is a lossless matched transmission line. Results support the ideas that (1) middle-ear transmission is consistent with a mechanical transmission line or multiresonant network between 5 and 35 kHz and decreases at higher frequencies, (2) stapes motion is pistonlike over most of the gerbil auditory range, and (3) middle-ear transmission properties are a determinant of the audiogram. PMID:18646983

  12. Malformations of the middle and inner ear on CT imaging in 22q11 deletion syndrome.

    PubMed

    Loos, Elke; Verhaert, Nicolas; Willaert, Annelore; Devriendt, Koenraad; Swillen, Ann; Hermans, Robert; Op de Beeck, Katya; Hens, Greet

    2016-11-01

    The 22q11 deletion syndrome (22q11DS), the most frequent microdeletion syndrome in humans, presents with a large variety of abnormalities. A common abnormality is hearing impairment. The exact pathophysiological explanation of the observed hearing loss remains largely unknown. The aim of this study was to analyze the middle and inner ear malformations as seen on computer tomographic imaging in patients with 22q11DS. We retrospectively reviewed the charts of 11 22q11DS patients who had undergone a CT of the temporal bone in the past. Of the 22 examined ears, two showed an abnormal malleus and incus, 10 presented with a dense stapes superstructure, and three ears had an abnormal orientation of the stapes. With regard to the inner ear, 12 ears showed an incomplete partition type II with a normal vestibular aqueduct. In four ears the vestibule and lateral semicircular canal were composed of a single cavity, in 14 ears the vestibule was too wide, and three ears had a broadened lateral semicircular canal. These findings suggest that malformations of the stapes, cochlea, vestibule, and lateral semicircular canal are frequent in 22q11DS. To our knowledge, the current study involves the largest case series describing middle and inner ear malformations in 22q11DS. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  13. Comparison of hearing results of nitinol SMART stapes piston prosthesis with conventional piston prostheses: postoperative results of nitinol stapes prosthesis.

    PubMed

    Harris, Jeffrey P; Gong, Shusheng

    2007-08-01

    Recently, a new stapedotomy piston prosthesis, which is a composite metal alloy of nickel and titanium known as nitinol, has been introduced into medical use. This biocompatible alloy has the unique property of shape-memory, which permits tight self-crimping when heat is applied to the wire. To substantiate the favorable initial observations with the SMART piston, this study was undertaken to compare these results (n=26) with those obtained using conventional stainless steel or platinum ribbon prostheses (n=28). Prospective consecutive case review: consecutive cases performed by the same surgeon were analyzed. Tertiary referral center. Fifty-four healthy patients with otosclerosis. Stapedotomy using either SMART prosthesis or conventional prosthesis. Hearing outcomes by audiological assessment. The postoperative hearing mean pure-tone average was 24.81+/-16.20 dBHL for Group 1 (SMART prosthesis) and 27.46+/-15.57 dBHL for Group 2 (conventional prosthesis). Postoperative mean air-bone gap was 7.07+/-8.14 dBHL for Group 1 and 6.38+/-7.54 dBHL for Group 2 using 0.5-, 1-, 2-, and 4-kHz frequencies. When analyzed according to the American Academy of Otolaryngology-Head & Neck Surgery reporting criteria using an estimate of 3 kHz as a mean of the 2-and 4-kHz values, the postoperative mean air-bone gap was 5.42+/-5.4 dBHL for Group 1 SMART and 5.98+/-5.47 dBHL for Group 2 conventional prostheses. Postoperative speech discrimination scores were 96%+/-8.64% and 97%+/-5.9%, respectively. These differences were not shown to be statistically different. Results demonstrate that experienced surgeons may achieve comparable results with both prostheses; however, the ease of self-crimping and the tightness of the crimp may provide advantages that may have long-term benefits. The potential issue of nickel allergy is important when considering patients for this prosthesis.

  14. A Randomised, Double Blind Trial of N-Acetylcysteine for Hearing Protection during Stapes Surgery

    PubMed Central

    Bagger-Sjöbäck, Dan; Strömbäck, Karin; Hakizimana, Pierre; Plue, Jan; Larsson, Christina; Hultcrantz, Malou; Papatziamos, Georgios; Smeds, Henrik; Danckwardt-Lillieström, Niklas; Hellström, Sten; Johansson, Ann; Tideholm, Bo; Fridberger, Anders

    2015-01-01

    Background Otosclerosis is a disorder that impairs middle ear function, leading to conductive hearing loss. Surgical treatment results in large improvement of hearing at low sound frequencies, but high-frequency hearing often suffers. A likely reason for this is that inner ear sensory cells are damaged by surgical trauma and loud sounds generated during the operation. Animal studies have shown that antioxidants such as N-Acetylcysteine can protect the inner ear from noise, surgical trauma, and some ototoxic substances, but it is not known if this works in humans. This trial was performed to determine whether antioxidants improve surgical results at high frequencies. Methods We performed a randomized, double-blind and placebo-controlled parallel group clinical trial at three Swedish university clinics. Using block-stratified randomization, 156 adult patients undergoing stapedotomy were assigned to intravenous N-Acetylcysteine (150 mg/kg body weight) or matching placebo (1:1 ratio), starting one hour before surgery. The primary outcome was the hearing threshold at 6 and 8 kHz; secondary outcomes included the severity of tinnitus and vertigo. Findings One year after surgery, high-frequency hearing had improved 2.7 ± 3.8 dB in the placebo group (67 patients analysed) and 2.4 ± 3.7 dB in the treated group (72 patients; means ± 95% confidence interval, p = 0.54; linear mixed model). Surgery improved tinnitus, but there was no significant intergroup difference. Post-operative balance disturbance was common but improved during the first year, without significant difference between groups. Four patients receiving N-Acetylcysteine experienced mild side effects such as nausea and vomiting. Conclusions N-Acetylcysteine has no effect on hearing thresholds, tinnitus, or balance disturbance after stapedotomy. Trial Registration ClinicalTrials.gov NCT00525551 PMID:25763866

  15. Application of the Vibrant Soundbridge in bilateral congenital atresia in toddlers.

    PubMed

    Frenzel, Henning; Hanke, Frauke; Beltrame, Millo; Wollenberg, Barbara

    2010-08-01

    The Vibrant Soundbridge offers an excellent audiologic rehabilitation for toddlers with microtia and atresia. It provides direct stimulation of the cochlea and straightforward adaption to the given anatomical structures. The 'posterior atresia incision' preserves the physical integrity of the tissue layers around the ear remnant, which is essential for an aesthetic auricular reconstruction. Patients with bilateral aural atresia require immediate auditory stimulation to ensure normal speech development. We present an operative technique that allows safe restoration of hearing before aesthetic reconstruction. A 6-year-old boy presented with bilateral microtia and osseous atresia. A hairline incision was performed through all layers and was followed by a subperiostal preparation towards the atresia plane. The fused malleus-incus-complex was removed and the transducer was crimped to the stapes suprastructure on both sides. Speech performance is nearly normal in both quiet and noise conditions. The surgery did not affect the tissues that are important for the later ear reconstruction.

  16. The "boomerang" malleus-incus complex in congenital aural atresia.

    PubMed

    Mukherjee, S; Kesser, B W; Raghavan, P

    2014-01-01

    "Boomerang" malleus-incus fusion deformity is identified on axial high-resolution CT in a subset of patients with congenital aural atresia, and it is associated with an absent incudostapedial joint and stapes capitulum and attachment of the incus to the tympanic segment of the facial nerve canal. Twelve patients with this deformity were identified on a retrospective review of imaging from a cohort of 673 patients with congenital aural atresia, with surgical confirmation in 9 of these patients. Eight of 9 patients underwent partial ossicular replacement prosthesis reconstruction with improvement in hearing outcome. We hypothesize that the boomerang anomaly represents a more severe ossicular anomaly than is normally seen in congenital aural atresia, arising from an arrest earlier in the embryonic development of the first and second branchial arch. This has potentially important implications for surgical planning because hearing outcomes with placement of prosthesis may not be as good as with conventional atresia surgery, in which reconstruction is performed with the patient's native ossicular chain. © 2014 by American Journal of Neuroradiology.

  17. Hearing Loss in Osteogenesis Imperfecta: Characteristics and Treatment Considerations

    PubMed Central

    Pillion, Joseph P.; Vernick, David; Shapiro, Jay

    2011-01-01

    Osteogenesis imperfecta (OI) is the most common heritable disorder of connective tissue. It is associated with fractures following relatively minor injury, blue sclerae, dentinogenesis imperfecta, increased joint mobility, short stature, and hearing loss. Structures in the otic capsule and inner ear share in the histologic features common to other skeletal tissues. OI is due to mutations involving several genes, the most commonly involved are the COL1A1 or COL1A2 genes which are responsible for the synthesis of the proalpha-1 and proalpha-2 polypeptide chains that form the type I collagen triple helix. A genotype/phenotype relationship to hearing loss has not been established in OI. Hearing loss is commonly found in OI with prevalence rates ranging from 50 to 92% in some studies. Hearing loss in OI may be conductive, mixed, or sensorineural and is more common by the second or third decade. Treatment options such as hearing aids, stapes surgery, and cochlear implants are discussed. PMID:22567374

  18. Optical and tomographic imaging of a middle ear malformation in the bullfrog (Rana catesbeiana).

    PubMed

    Horowitz, Seth S; Simmons, Andrea Megela; Ketten, Darlene R

    2005-08-01

    Using a combination of in vivo computerized tomography and histological staining, a middle ear anomaly in two wild-caught American bullfrogs (Rana catesbeiana) is characterized. In these animals, the tympanic membrane, extrastapes, and pars media (shaft) of the stapes are absent on one side of the head, with the other side exhibiting normal morphology. The pars interna (footplate) of the stapes and the operculum are present in their normal positions at the entrance of the otic capsule on both the affected and unaffected sides. The pattern of deformity suggests a partial failure of development of tympanic pathway tissues, but with a preservation of the opercularis pathway. While a definitive proximate cause of the condition could not be determined, the anomalies show similarities to developmental defects in mammalian middle ear formation.

  19. Optical and tomographic imaging of a middle ear malformation in the bullfrog (Rana catesbeiana)

    PubMed Central

    Horowitz, Seth S.; Simmons, Andrea Megela; Ketten, Darlene R.

    2005-01-01

    Using a combination of in vivo computerized tomography and histological staining, a middle ear anomaly in two wild-caught American bullfrogs (Rana catesbeiana) is characterized. In these animals, the tympanic membrane, extrastapes, and pars media (shaft) of the stapes are absent on one side of the head, with the other side exhibiting normal morphology. The pars interna(footplate) of the stapes and the operculum are present in their normal positions at the entrance of the otic capsule on both the affected and unaffected sides. The pattern of deformity suggests a partial failure of development of tympanic pathway tissues, but with a preservation of theopercularis pathway. While a definitive proximate cause of the condition could not be determined, the anomalies show similarities to developmental defects in mammalian middle ear formation. PMID:16158670

  20. Transmission matrix analysis of the chinchilla middle ear

    PubMed Central

    Songer, Jocelyn E.; Rosowski, John J.

    2008-01-01

    Despite the common use of the chinchilla as an animal model in auditory research, a complete characterization of the chinchilla middle ear using transmission matrix analysis has not been performed. In this paper we describe measurements of middle-ear input admittance and stapes velocity in ears with the middle-ear cavity opened under three conditions: intact tympano-ossicular system and cochlea, after the cochlea has been drained, and after the stapes has been fixed. These measurements, made with stimulus frequencies of 100–8000 Hz, are used to define the transmission matrix parameters of the middle ear and to calculate the cochlear input impedance as well as the middle-ear output impedance. This transmission characterization of the chinchilla middle ear will be useful for modeling auditory sensitivity in the normal and pathological chinchilla ear. PMID:17672642

  1. The Glasgow Benefit Inventory: a systematic review of the use and value of an otorhinolaryngological generic patient-recorded outcome measure

    PubMed Central

    Hendry, J.; Chin, A.; Swan, I.R.C.; Akeroyd, M.A.; Browning, G.G.

    2018-01-01

    Background The Glasgow Benefit Inventory (GBI) is a validated, generic patient-recorded outcome measure widely used in otolaryngology to report change in quality of life post-intervention. Objectives of review To date, no systematic review has made (i) a quality assessment of reporting of Glasgow Benefit Inventory outcomes; (ii) a comparison between Glasgow Benefit Inventory outcomes for different interventions and objectives; (iii) an evaluation of subscales in describing the area of benefit; (iv) commented on its value in clinical practice and research. Type of review Systematic review. Search strategy ‘Glasgow Benefit Inventory’ and ‘GBI’ were used as keywords to search for published, unpublished and ongoing trials in PubMed, EMBASE, CINAHL and Google in addition to an ISI citation search for the original validating Glasgow Benefit Inventory paper between 1996 and January 2015. Evaluation method Papers were assessed for study type and quality graded by a predesigned scale, by two authors independently. Papers with sufficient quality Glasgow Benefit Inventory data were identified for statistical comparisons. Papers with <50% follow-up were excluded. Results A total of 118 eligible papers were identified for inclusion. A national audit paper (n = 4325) showed that the Glasgow Benefit Inventory gave a range of scores across the specialty, being greater for surgical intervention than medical intervention or ‘reassurance’. Fourteen papers compared one form of surgery versus another form of surgery. In all but one study, there was no difference between the Glasgow Benefit Inventory scores (or of any other outcome). The most likely reason was lack of power. Two papers took an epidemiological approach and used the Glasgow Benefit Inventory scores to predict benefit. One was for tonsillectomy where duration of sore throat episodes and days with fever were identified on multivariate analysis to predict benefit albeit the precision was low. However, the traditional factor of number of episodes of sore throat was not predictive. The other was surgery for chronic rhinosinusitis where those with polyps on univariate analysis had greater benefit than those without. Forty-three papers had a response rate of >50% and gave sufficient Glasgow Benefit Inventory total and subscales for meta-analysis. For five of the 11 operation categories (vestibular schwannoma, tonsillectomy, cochlear implant, middle ear implant and stapes surgery) that were most likely to have a single clear clinical objective, score data had low-to-moderate heterogeneity. The value in the Glasgow Benefit Inventory having both positive and negative scores was shown by an overall negative score for the management of vestibular schwannoma. The other six operations gave considerable heterogeneity with rhinoplasty and septoplasty giving the greatest percentages (98% and 99%) most likely because of the considerable variations in patient selection. The data from these operations should not be used for comparative purposes. Five papers also reported the number of patients that had no or negative benefit, a potentially a more clinically useful outcome to report. Glasgow Benefit Inventory subscores for tonsillectomy were significantly different from ear surgery suggesting different areas of benefit Conclusions The Glasgow Benefit Inventory has been shown to differentiate the benefit between surgical and medical otolaryngology interventions as well as ‘reassurance’. Reporting benefit as percentages with negative, no and positive benefit would enable better comparisons between different interventions with varying objectives and pathology. This could also allow easier evaluation of factors that predict benefit. Meta-analysis data are now available for comparison purposes for vestibular schwannoma, tonsillectomy, cochlear implant, middle ear implant and stapes surgery. Fuller report of the Glasgow Benefit Inventory outcomes for non-surgical otolaryngology interventions is encouraged. PMID:26264703

  2. The Glasgow Benefit Inventory: a systematic review of the use and value of an otorhinolaryngological generic patient-recorded outcome measure.

    PubMed

    Hendry, J; Chin, A; Swan, I R C; Akeroyd, M A; Browning, G G

    2016-06-01

    The Glasgow Benefit Inventory (GBI) is a validated, generic patient-recorded outcome measure widely used in otolaryngology to report change in quality of life post-intervention. To date, no systematic review has made (i) a quality assessment of reporting of Glasgow Benefit Inventory outcomes; (ii) a comparison between Glasgow Benefit Inventory outcomes for different interventions and objectives; (iii) an evaluation of subscales in describing the area of benefit; (iv) commented on its value in clinical practice and research. Systematic review. 'Glasgow Benefit Inventory' and 'GBI' were used as keywords to search for published, unpublished and ongoing trials in PubMed, EMBASE, CINAHL and Google in addition to an ISI citation search for the original validating Glasgow Benefit Inventory paper between 1996 and January 2015. Papers were assessed for study type and quality graded by a predesigned scale, by two authors independently. Papers with sufficient quality Glasgow Benefit Inventory data were identified for statistical comparisons. Papers with <50% follow-up were excluded. A total of 118 eligible papers were identified for inclusion. A national audit paper (n = 4325) showed that the Glasgow Benefit Inventory gave a range of scores across the specialty, being greater for surgical intervention than medical intervention or 'reassurance'. Fourteen papers compared one form of surgery versus another form of surgery. In all but one study, there was no difference between the Glasgow Benefit Inventory scores (or of any other outcome). The most likely reason was lack of power. Two papers took an epidemiological approach and used the Glasgow Benefit Inventory scores to predict benefit. One was for tonsillectomy where duration of sore throat episodes and days with fever were identified on multivariate analysis to predict benefit albeit the precision was low. However, the traditional factor of number of episodes of sore throat was not predictive. The other was surgery for chronic rhinosinusitis where those with polyps on univariate analysis had greater benefit than those without. Forty-three papers had a response rate of >50% and gave sufficient Glasgow Benefit Inventory total and subscales for meta-analysis. For five of the 11 operation categories (vestibular schwannoma, tonsillectomy, cochlear implant, middle ear implant and stapes surgery) that were most likely to have a single clear clinical objective, score data had low-to-moderate heterogeneity. The value in the Glasgow Benefit Inventory having both positive and negative scores was shown by an overall negative score for the management of vestibular schwannoma. The other six operations gave considerable heterogeneity with rhinoplasty and septoplasty giving the greatest percentages (98% and 99%) most likely because of the considerable variations in patient selection. The data from these operations should not be used for comparative purposes. Five papers also reported the number of patients that had no or negative benefit, a potentially a more clinically useful outcome to report. Glasgow Benefit Inventory subscores for tonsillectomy were significantly different from ear surgery suggesting different areas of benefit The Glasgow Benefit Inventory has been shown to differentiate the benefit between surgical and medical otolaryngology interventions as well as 'reassurance'. Reporting benefit as percentages with negative, no and positive benefit would enable better comparisons between different interventions with varying objectives and pathology. This could also allow easier evaluation of factors that predict benefit. Meta-analysis data are now available for comparison purposes for vestibular schwannoma, tonsillectomy, cochlear implant, middle ear implant and stapes surgery. Fuller report of the Glasgow Benefit Inventory outcomes for non-surgical otolaryngology interventions is encouraged. © 2015 The Authors. Clinical Otolaryngology Published by John Wiley & Sons Ltd.

  3. How to Avoid a Learning Curve in Stapedotomy: A Standardized Surgical Technique.

    PubMed

    Kwok, Pingling; Gleich, Otto; Dalles, Katharina; Mayr, Elisabeth; Jacob, Peter; Strutz, Jürgen

    2017-08-01

    To evaluate, whether a learning curve for beginners in stapedotomy can be avoided by using a prosthesis with thermal memory-shape attachment in combination with a standardized laser-assisted surgical technique. Retrospective case review. Tertiary referral center. Fifty-eight ears were operated by three experienced surgeons and compared with a group of 12 cases operated by a beginner in stapedotomy. Stapedotomy. Difference of pure-tone audiometry thresholds measured before and after surgery. The average postoperative gain for air conduction in the frequencies below 2 kHz was 20 to 25 dB and decreased for the higher frequencies. Using the Mann-Whitney-U test for comparing mean gain between experienced and inexperienced surgeons showed no significant difference (p = 0.281 at 4 kHz and p > 0.7 for the other frequencies). A Spearman rank correlation of the postoperative gain for air- and bone-conduction thresholds was obtained at each test frequency for the first 12 patients consecutively treated with a thermal memory-shape attachment prosthesis by two experienced and one inexperienced surgeon. This analysis does not support the hypothesis of a "learning effect" that should be associated with an improved outcome for successively treated patients. It is possible to avoid a learning curve in stapes surgery by applying a thermal memory-shape prosthesis in a standardized laser-assisted surgical procedure.

  4. Surgical Management and Hearing Outcome of Traumatic Ossicular Injuries.

    PubMed

    Delrue, Stefan; Verhaert, Nicolas; Dinther, Joost van; Zarowski, Andrzej; Somers, Thomas; Desloovere, Christian; Offeciers, Erwin

    2016-12-01

    The purpose of this study was to investigate etiological, clinical, and pathological characteristics of traumatic injuries of the middle ear ossicular chain and to evaluate hearing outcome after surgery. Thirty consecutive patients (31 ears) with traumatic ossicular injuries operated on between 2004 and 2015 in two tertiary referral otologic centers were retrospectively analyzed. Traumatic events, clinical features, ossicular lesions, treatment procedures, and audiometric results were evaluated. Air conduction (AC), bone conduction (BC), and air-bone gap (ABG) were analyzed preoperatively and postoperatively. Amsterdam Hearing Evaluation Plots (AHEPs) were used to visualize the individual hearing results. The mean age at the moment of trauma was 27.9±17.1 years (range, 2-75 years) and the mean age at surgery was 33.2±16.3 years (range, 5-75 years). In 10 cases (32.3%), the injury occurred by a fall on the head and in 9 (29.0%) by a traffic accident. Isolated luxation of the incus was observed in 8 cases (25.8%). Dislocation of the stapes footplate was seen in 4 cases (12.9%). The postoperative ABG closure to within 10 and 20 dB was 30% and 76.7%, respectively. Ossicular chain injury by direct or indirect trauma can provoke hearing loss, tinnitus, and vertigo. As injuries are heterogeneous, they require a tailored surgical approach. In this study, the overall hearing outcome after surgical repair was favorable.

  5. The Codacs™ direct acoustic cochlear implant actuator: exploring alternative stimulation sites and their stimulation efficiency.

    PubMed

    Grossöhmichen, Martin; Salcher, Rolf; Kreipe, Hans-Heinrich; Lenarz, Thomas; Maier, Hannes

    2015-01-01

    This work assesses the efficiency of the Codacs system actuator (Cochlear Ltd., Sydney Australia) in different inner ear stimulation modalities. Originally the actuator was intended for direct perilymph stimulation after stapedotomy using a piston prosthesis. A possible alternative application is the stimulation of middle ear structures or the round window (RW). Here the perilymph stimulation with a K-piston through a stapes footplate (SFP) fenestration (N = 10) as well as stimulation of the stapes head (SH) with a Bell prosthesis (N = 9), SFP stimulation with an Omega/Aerial prosthesis (N = 8) and reverse RW stimulation (N = 10) were performed in cadaveric human temporal bones (TBs). Codacs actuator output is expressed as equivalent sound pressure level (eq. SPL) using RW and SFP displacement responses, measured by Laser Doppler velocimetry as reference. The axial actuator coupling force in stimulation of stapes and RW was adjusted to ~5 mN. The Bell prosthesis and Omega/Aerial prosthesis stimulation generated similar mean eq. SPLs (Bell: 127.5-141.8 eq. dB SPL; Omega/Aerial: 123.6-143.9 eq. dB SPL), being significantly more efficient than K-piston perilymph stimulation (108.6-131.6 eq. dB SPL) and RW stimulation (108.3-128.2 eq. dB SPL). Our results demonstrate that SH, SFP and RW are adequate alternative stimulation sites for the Codacs actuator using coupling prostheses and an axial coupling force of ~5 mN. Based on the eq. SPLs, all investigated methods were adequate for in vivo hearing aid applications, provided that experimental conditions including constant coupling force will be implemented.

  6. HDR syndrome with a novel mutation in GATA3 mimicking a congenital X-linked stapes gusher: a case report.

    PubMed

    Yang, Aram; Kim, Jinsup; Ki, Chang-Seok; Hong, Sung Hwa; Cho, Sung Yoon; Jin, Dong-Kyu

    2017-10-26

    Hypoparathyroidism, sensorineural hearing loss, and renal disease (HDR) syndrome, also known as Barakat syndrome, is a rare genetic disorder with high phenotypic heterogeneity caused by haploinsufficiency of the GATA3 gene on chromosome 10p14-p15. For these reasons, the diagnosis of HDR syndrome is challenging and requires a high index of suspicion as well as genetic analysis. A 14-month-old boy, with sensorineural hearing loss in both ears, showed typical radiological features of X-linked stapes gusher on preoperative temporal bone computed tomography (CT) for cochlear implantations. Then after his discharge from hospital, he suffered a hypocalcemic seizure and we discovered a renal cyst during investigation of hypocalcemia. He was finally diagnosed with HDR syndrome by clinical findings, which were confirmed by molecular genetic testing. Direct sequencing of the GATA3 gene showed a heterozygous 2-bp deletion (c.1201_1202delAT), which is predicted to cause a frameshift of the reading frame (p.Met401Valfs*106). To our knowledge, this is the first case of HDR syndrome with a novel de novo variant mimicking a congenital X-linked stapes gusher syndrome. Novel mutations and the diversity of clinical manifestations expand the genotypic and phenotypic spectrum of HDR syndrome. Diagnosis of HDR syndrome is still challenging, but clinicians should consider it in their differential diagnosis for children with a wide range of clinical manifestations including hypocalcemia induced seizures and deafness. We hope that this case will contribute to further understanding and studies of HDR-associated GATA3 mutations.

  7. [Virtual otoscopy--technique, indications and initial experiences with multislice spiral CT].

    PubMed

    Klingebiel, R; Bauknecht, H C; Lehmann, R; Rogalla, P; Werbs, M; Behrbohm, H; Kaschke, O

    2000-11-01

    We report the standardized postprocessing of high-resolution CT data acquired by incremental CT and multi-slice CT in patients with suspected middle ear disorders to generate three-dimensional endoluminal views known as virtual otoscopy. Subsequent to the definition of a postprocessing protocol, standardized endoluminal views of the middle ear were generated according to their otological relevance. The HRCT data sets of 26 ENT patients were transferred to a workstation and postprocessed to 52 virtual otoscopies. Generation of predefined endoluminal views from the HRCT data sets was possible in all patients. Virtual endoscopic views added meaningful information to the primary cross-sectional data in patients suffering from ossicular pathology, having contraindications for invasive tympanic endoscopy or being assessed for surgery of the tympanic cavity. Multi slice CT improved the visualization of subtle anatomic details such as the stapes suprastructure and reduced the scanning time. Virtual endoscopy allows for the non invasive endoluminal visualization of various tympanic lesions. Use of the multi-slice CT technique reduces the scanning time and improves image quality in terms of detail resolution.

  8. Incudomalleal joint formation: the roles of apoptosis, migration and downregulation

    PubMed Central

    Amin, Susan; Matalova, Eva; Simpson, Carol; Yoshida, Hiroki; Tucker, Abigail S

    2007-01-01

    Background The middle ear of mammals is composed of three endochondrial ossicles, the stapes, incus and malleus. Joints link the malleus to the incus and the incus to the stapes. In the mouse the first arch derived malleus and incus are formed from a single Sox9 and Type II collagen expressing condensation that later subdivides to give rise to two separate ossicles. In contrast the stapes forms from a separate condensation derived from the second branchial arch. Fusion of the malleus and incus is observed in a number of human syndromes and results in conductive hearing loss. Understanding how this joint forms during normal development is thus an important step in furthering our understanding of such defects. Results We show that the developing incudomalleal joint is characterised by a lack of proliferation and discrete areas of apoptosis. Apoptosis has been suggested to aid in the removal of pre-cartilaginous cells from the joint region, allowing for the physical separation of the cartilaginous elements, however, we show that joint initiation is unaffected by blocking apoptosis. There is also no evidence of cell migration out of the presumptive joint region, as observed by labelling of joint and ossicle cells in culture. Using Type II collagen lacZ reporter mice, however, it is evident that cells in the presumptive joint region remain in place and downregulate cartilage markers. Conclusion The malleus and incus first appear as a single united condensation expressing early cartilage markers. The incudomalleal joint region forms by cells in the presumptive joint region switching off cartilage markers and turning on joint markers. Failure in this process may result in fusion of this joint, as observed in human syndromes such as Branchio-Oto-Renal Syndrome or Treacher Collins Syndrome. PMID:18053235

  9. The Codacs™ Direct Acoustic Cochlear Implant Actuator: Exploring Alternative Stimulation Sites and Their Stimulation Efficiency

    PubMed Central

    Grossöhmichen, Martin; Salcher, Rolf; Kreipe, Hans-Heinrich; Lenarz, Thomas; Maier, Hannes

    2015-01-01

    This work assesses the efficiency of the Codacs system actuator (Cochlear Ltd., Sydney Australia) in different inner ear stimulation modalities. Originally the actuator was intended for direct perilymph stimulation after stapedotomy using a piston prosthesis. A possible alternative application is the stimulation of middle ear structures or the round window (RW). Here the perilymph stimulation with a K-piston through a stapes footplate (SFP) fenestration (N = 10) as well as stimulation of the stapes head (SH) with a Bell prosthesis (N = 9), SFP stimulation with an Omega/Aerial prosthesis (N = 8) and reverse RW stimulation (N = 10) were performed in cadaveric human temporal bones (TBs). Codacs actuator output is expressed as equivalent sound pressure level (eq. SPL) using RW and SFP displacement responses, measured by Laser Doppler velocimetry as reference. The axial actuator coupling force in stimulation of stapes and RW was adjusted to ~ 5 mN. The Bell prosthesis and Omega/Aerial prosthesis stimulation generated similar mean eq. SPLs (Bell: 127.5–141.8 eq. dB SPL; Omega/Aerial: 123.6–143.9 eq. dB SPL), being significantly more efficient than K-piston perilymph stimulation (108.6–131.6 eq. dB SPL) and RW stimulation (108.3–128.2 eq. dB SPL). Our results demonstrate that SH, SFP and RW are adequate alternative stimulation sites for the Codacs actuator using coupling prostheses and an axial coupling force of ~ 5 mN. Based on the eq. SPLs, all investigated methods were adequate for in vivo hearing aid applications, provided that experimental conditions including constant coupling force will be implemented. PMID:25785860

  10. Middle Ear Mechanics of Cartilage Tympanoplasty Evaluated by Laser Holography and Vibrometry

    PubMed Central

    Aarnisalo, Antti A.; Cheng, Jeffrey T.; Ravicz, Michael E.; Hulli, Nesim; Harrington, Ellery J.; Hernandez-Montes, Maria S.; Furlong, Cosme; Merchant, Saumil N.; Rosowski, John J.

    2010-01-01

    Goals To assess the effects of thickness and position of cartilage used to reconstruct the tympanic membrane (TM) using a novel technique, time-averaged laser holography. Background Cartilage is commonly used in TM reconstruction to prevent formation of retraction pockets. The thickness, position, and shape of the cartilage graft may adversely affect TM motion and hearing. We sought to systematically investigate these parameters in an experimental setting. Methods Computer-assisted optoelectronic laser holography was used in 4 human cadaveric temporal bones to study sound-induced TM motion for 500 Hz to 8 kHz. Stapes velocity was measured with a laser Doppler vibrometer. Baseline (control) measurements were made with the TM intact. Measurements were repeated after a 0.5- or 1.0-mm-thick oval piece of conchal cartilage was placed on the medial TM surface in the posterior-superior quadrant. The cartilage was rotated so that it was either in contact with the bony tympanic rim and manubrium or not. Results At frequencies less than 4 kHz, the cartilage graft had only minor effects on the overall TM fringe patterns. The different conditions had no effects on stapes velocity. Greater than 4 kHz, TM motion was reduced over the grafted TM, both with 0.5- and 1.0-mm-thick grafts. No significant differences in stapes velocity were seen with the 2 different thicknesses of cartilage compared with control. Conclusion Computer-assisted optoelectronic laser holography is a promising technique to investigate middle ear mechanics after tympanoplasty. Such positioning may prevent postoperative TM retraction. These findings and conclusions apply to cartilage placed in the posterior-superior TM quadrant. PMID:19779389

  11. Biomechanical Analysis of Hearing in Whales Using Nanoindentation and the Finite Element Method

    NASA Astrophysics Data System (ADS)

    Tubelli, Andrew A.; Zosuls, Aleks; Ketten, Darlene R.; Mountain, David C.

    2011-11-01

    The detailed biomechanics of hearing in baleen whales are almost entirely unknown. As a first step to predicting the audiogram for these species, a linear three-dimensional finite-element model of the minke whale (Balaenoptera acutorostrata) middle ear was developed. A reconstruction of the ear was made from CT scans and imported into a finite element solver. Young's modulus of the bone was estimated via nanoindentation. The middle-ear transfer function was estimated by applying a pressure to the glove finger (the thick, everted equivalent of the tympanic membrane) with velocity calculated at the stapes footplate. It was found that the most sensitive frequencies corresponded with vocalization frequencies. For all frequencies tested, the malleus-incus complex flexed about the anterior process of the malleus and the stapes rotated within the oval window. Results indictae that finite element modeling is a useful approach for studying the mechanics of hearing in species that are difficult to study in vivo.

  12. Vibrant Soundbridge Implantation: Floating Mass Transducer Coupled with the Stapes Head and Embedded in Fat.

    PubMed

    Liu, Qingsong; Feng, Guodong; Shang, Yingying; Wang, Suju; Gao, Zhiqiang

    2018-04-26

    Subtotal petrosectomy may be performed for refractory chronic middle ear diseases, such as massive cholesteatoma or recurrent otitis media. It involves permanent obliteration of the operative cavity, thus precluding the chance to restore conductive hearing via traditional inertial ossicular prostheses. The Vibrant Soundbridge (VSB) is an alternative option for hearing rehabilitation. Vibrant energy is delivered into the inner ear via a floating mass transducer (FMT), which can be coupled with any part of the middle ear acoustic transmission structure. To restore the hearing of a young woman with cholesteatoma, we combined subtotal petrosectomy with obliteration of the cavity and VSB implantation with an FMT coupled to the stapes head. Two years of follow-up demonstrated excellent auditory rehabilitation, improved sound source localization ability, and a lower speech recognition threshold. This study showed that the FMT works well in an obliterated cavity, and the experience acquired through this successful exploration is worth disseminating. © 2018 S. Karger AG, Basel.

  13. Sequential motion of the ossicular chain measured by laser Doppler vibrometry.

    PubMed

    Kunimoto, Yasuomi; Hasegawa, Kensaku; Arii, Shiro; Kataoka, Hideyuki; Yazama, Hiroaki; Kuya, Junko; Fujiwara, Kazunori; Takeuchi, Hiromi

    2017-12-01

    In order to help a surgeon make the best decision, a more objective method of measuring ossicular motion is required. A laser Doppler vibrometer was mounted on a surgical microscope. To measure ossicular chain vibrations, eight patients with cochlear implants were investigated. To assess the motions of the ossicular chain, velocities at five points were measured with tonal stimuli of 1 and 3 kHz, which yielded reproducible results. The sequential amplitude change at each point was calculated with phase shifting from the tonal stimulus. Motion of the ossicular chain was visualized from the averaged results using the graphics application. The head of the malleus and the body of the incus showed synchronized movement as one unit. In contrast, the stapes (incudostapedial joint and posterior crus) moved synchronously in opposite phase to the malleus and incus. The amplitudes at 1 kHz were almost twice those at 3 kHz. Our results show that the malleus and incus unit and the stapes move with a phase difference.

  14. The influence of the footplate-perilymph interface on postoperative bone conduction.

    PubMed

    Arnold, Wolfgang; Ferekidis, Elefterios; Hamann, Karl-Friedrich

    2007-01-01

    In a prospective study, 165 total stapedectomies and 152 small fenestra stapedotomies were performed by three experienced surgeons between 2001 and 2003. In total stapedectomy, a self-made Schuknecht steel wire connective tissue prosthesis, and in stapedotomy, a 0.6-mm platinum wire Teflon piston was used. The pre- and postoperative bone conduction thresholds were compared at the frequencies 250 Hz, 500 Hz, 1 kHz, 1.5 kHz, 2 kHz, 3 kHz and 4 kHz. The postoperative bone conduction between 250 Hz and 3 kHz was significantly better in the total stapedectomy group than in the stapedotomy group. At 4 kHz, both groups showed a slight decrease in bone conduction but the difference was not statistically significant. Therefore, especially in cases with preoperative moderate sensorineural hearing loss, we recommend total stapedectomy using a Schuknecht steel wire connective tissue prosthesis, which offers a stapes-perilymph interface similar to the normal stapes.

  15. Hearing rehabilitation with single-stage bilateral vibroplasty in a child with Franceschetti syndrome.

    PubMed

    Sargsyan, Sona; Rahne, Torsten; Kösling, Sabrina; Eichler, Gerburg; Plontke, Stefan K

    2014-05-01

    Hearing is of utmost importance for normal speech and social development. Even children who have mild or unilateral permanent hearing loss may experience difficulties with understanding speech, as well as problems with educational and psycho-social development. The increasing advantages of middle-ear implant technologies are opening new perspectives for restoring hearing. Active middle-ear implants can be used in children and adolescents with hearing loss. In addition to the well-documented results for improving speech intelligibility and quality of hearing in sensorineural hearing loss active middle-ear implants are now successfully used in patients with conductive and mixed hearing loss. In this article we present a case of successful, single-stage vibroplasty, on the right side with the fixation of the FMT on the stapes and PORP CLiP vibroplasty on the left side in a 6-year-old girl with bilateral mixed hearing loss and multiple dyslalia associated with Franceschetti syndrome (mandibulofacial dysostosis). CT revealed bilateral middle-ear malformations as well as an atretic right and stenotic left external auditory canal. Due to craniofacial dysmorphia airway and (post)operative, management is significantly more difficult in patients with a Franceschetti syndrome which in this case favoured a single-stage bilateral procedure. No intra- or postoperative surgical complications were reported. The middle-ear implants were activated 4 weeks after surgery. In the audiological examination 6 months after surgery, the child showed 100% speech intelligibility with activated implants on each side.

  16. Creating an Optimal 3D Printed Model for Temporal Bone Dissection Training.

    PubMed

    Takahashi, Kuniyuki; Morita, Yuka; Ohshima, Shinsuke; Izumi, Shuji; Kubota, Yamato; Yamamoto, Yutaka; Takahashi, Sugata; Horii, Arata

    2017-07-01

    Making a 3-dimensional (3D) temporal bone model is simple using a plaster powder bed and an inkjet printer. However, it is difficult to reproduce air-containing spaces and precise middle ear structures. The objective of this study was to overcome these problems and create a temporal bone model that would be useful both as a training tool and for preoperative simulation. Drainage holes were made to remove excess materials from air-containing spaces, ossicle ligaments were manually changed to bony structures, and small and/or soft tissue structures were colored differently while designing the 3D models. The outcomes were evaluated by 3 procedures: macroscopic and endoscopic inspection of the model, comparison of computed tomography (CT) images of the model to the original CT, and assessment of tactile sensation and reproducibility by 20 surgeons performing surgery on the model. Macroscopic and endoscopic inspection, CT images, and assessment by surgeons were in agreement in terms of reproducibility of model structures. Most structures could be reproduced, but the stapes, tympanic sinus, and mastoid air cells were unsatisfactory. Perioperative tactile sensation of the model was excellent. Although this model still does not embody perfect reproducibility, it proved sufficiently practical for use in surgical training.

  17. Integrating optical fiber force sensors into microforceps for ORL microsurgery.

    PubMed

    Bell, Brett; Stankowski, Stefan; Moser, Benjamin; Oliva, Vidina; Stieger, Christof; Nolte, Lutz-Peter; Caversaccio, Marco; Weber, Stefan

    2010-01-01

    The delicate anatomy of the ear require surgeons to use great care when operating on its internal structures. One example for such an intervention is the stapedectomy, where a small crook shaped piston is placed in the oval window of the cochlea and connected to the incus through crimping thus bypassing the diseased stapes. Performing the crimp process with the correct force is necessary since loose crimps poorly transmit sound whereas tight crimps will eventually result in necrosis of the incus. Clinically, demand is high to reproducibly conduct the crimp process through a precise force measurement. For this reason, we have developed a fiber Bragg grating (FBG) integrated microforceps for use in such interventions. This device was calibrated, and tested in cadaver preparations. With this instrument we were able to measure for the first time forces involved in crimping a stapes prosthesis to the incus. We also discuss a method of attaching and actuating such forceps in conjunction with a robot currently under development in our group. Each component of this system can be used separately or combined to improve surgical accuracy, confidence and outcome.

  18. Experimental measurement and modeling analysis on mechanical properties of incudostapedial joint

    PubMed Central

    Zhang, Xiangming

    2011-01-01

    The incudostapedial (IS) joint between the incus and stapes is a synovial joint consisting of joint capsule, cartilage, and synovial fluid. The mechanical properties of the IS joint directly affect the middle ear transfer function for sound transmission. However, due to the complexity and small size of the joint, the mechanical properties of the IS joint have not been reported in the literature. In this paper, we report our current study on mechanical properties of human IS joint using both experimental measurement and finite element (FE) modeling analysis. Eight IS joint samples with the incus and stapes attached were harvested from human cadaver temporal bones. Tension, compression, stress relaxation and failure tests were performed on those samples in a micro-material testing system. An analytical approach with the hyperelastic Ogden model and a 3D FE model of the IS joint including the cartilage, joint capsule, and synovial fluid were employed to derive mechanical parameters of the IS joint. The comparison of measurements and modeling results reveals the relationship between the mechanical properties and structure of the IS joint. PMID:21061141

  19. Experimental measurement and modeling analysis on mechanical properties of incudostapedial joint.

    PubMed

    Zhang, Xiangming; Gan, Rong Z

    2011-10-01

    The incudostapedial (IS) joint between the incus and stapes is a synovial joint consisting of joint capsule, cartilage, and synovial fluid. The mechanical properties of the IS joint directly affect the middle ear transfer function for sound transmission. However, due to the complexity and small size of the joint, the mechanical properties of the IS joint have not been reported in the literature. In this paper, we report our current study on mechanical properties of human IS joint using both experimental measurement and finite element (FE) modeling analysis. Eight IS joint samples with the incus and stapes attached were harvested from human cadaver temporal bones. Tension, compression, stress relaxation and failure tests were performed on those samples in a micro-material testing system. An analytical approach with the hyperelastic Ogden model and a 3D FE model of the IS joint including the cartilage, joint capsule, and synovial fluid were employed to derive mechanical parameters of the IS joint. The comparison of measurements and modeling results reveals the relationship between the mechanical properties and structure of the IS joint.

  20. Hearing results in otosclerosis surgery after partial stapedectomy, total stapedectomy and stapedotomy.

    PubMed

    Persson, P; Harder, H; Magnuson, B

    1997-01-01

    Hearing results in a consecutive series of 407 patients with otosclerosis undergoing primary stapes surgery were analysed (437 operated ears). Partial stapedectomy was performed in 70 ears (16%), total stapedectomy in 205 ears (47%), in both groups using the House steel wire prosthesis on fascia in the oval window. The remaining 162 ears (37%) underwent stapedotomy using the Fisch 0.4 mm teflon-platinum piston. No case of cochlear loss (> 15 dB) occurred in the total series. The comparison between the three groups one year postoperatively showed that the air-bone gap was smaller for partial and total stapedectomy for all frequencies except 4 kHz. The air-bone gap was calculated as the difference between the preoperative bone conduction and the postoperative air conduction thresholds. Partial and total stapedectomy also showed larger improvements of bone conduction thresholds compared with stapedotomy for all frequencies but 4 kHz. At the 3-year follow-up, the hearing gain for all frequencies (250-8000 Hz) was larger for partial and total stapedectomy. Yet, when comparing the decline of hearing from 1 to 3 year postoperatively, the hearing gain achieved with partial and total stapedectomy seemed to deteriorate at a higher rate, which was considered to be caused by impaired sensorineural function. Our results show that in the short-term perspective partial or total stapedectomy can still compete for better hearing results even at higher frequencies, but stapedotomy seems to yield more stable hearing results over time and should therefore be considered as the method of choice.

  1. The Effect of Superior Semicircular Canal Dehiscence on Intracochlear Sound Pressures

    PubMed Central

    Pisano, Dominic V.; Niesten, Marlien E.F.; Merchant, Saumil N.; Nakajima, Hideko Heidi

    2013-01-01

    Semicircular canal dehiscence (SCD) is a pathological opening in the bony wall of the inner ear that can result in conductive hearing loss. The hearing loss is variable across patients, and the precise mechanism and source of variability are not fully understood. Simultaneous measurements of basal intracochlear sound pressures in scala vestibuli (SV) and scala tympani (ST) enable quantification of the differential pressure across the cochlear partition, the stimulus that excites the cochlear partition. We used intracochlear sound pressure measurements in cadaveric preparations to study the effects of SCD size. Sound-induced pressures in SV and ST, as well as stapes velocity and ear-canal pressure were measured simultaneously for various sizes of SCD followed by SCD patching. Our results showed that at low frequencies (<600 Hz), SCD decreased the pressure in both SV and ST, as well as differential pressure, and these effects became more pronounced as dehiscence size was increased. Near 100 Hz, SV decreased about 10 dB for a 0.5 mm dehiscence and 20 dB for a 2 mm dehiscence, while ST decreased about 8 dB for a 0.5 mm dehiscence and 18 dB for a 2mm dehiscence. Differential pressure decreased about 10 dB for a 0.5 mm dehiscence and about 20 dB for a 2 mm dehiscense at 100 Hz. In some ears, for frequencies above 1 kHz, the smallest pinpoint dehiscence had bigger effects on the differential pressure (10 dB decrease) than larger dehiscenses (less than 10 dB decrease), suggesting larger hearing losses in this frequency range. These effects due to SCD were reversible by patching the dehiscence. We also showed that under certain circumstances such as SCD, stapes velocity is not related to how the ear can transduce sound across the cochlear partition because it is not directly related to the differential pressure, emphasizing that certain pathologies cannot be fully assessed by measurements such as stapes velocity. PMID:22814034

  2. Visualization of Middle Ear Ossicles in Elder Subjects with Ultra-short Echo Time MR Imaging.

    PubMed

    Naganawa, Shinji; Nakane, Toshiki; Kawai, Hisashi; Taoka, Toshiaki; Suzuki, Kojiro; Iwano, Shingo; Satake, Hiroko; Grodzki, David

    2017-04-10

    To evaluate the visualization of middle ear ossicles by ultra-short echo time magnetic resonance (MR) imaging at 3T in subjects over 50 years old. Sixty ears from 30 elder patients that underwent surgical or interventional treatment for neurovascular diseases were included (ages: 50-82, median age: 65; 10 men, 20 women). Patients received follow-up MR imaging including routine T 1 - and T 2 -weighted images, time-of-flight MR angiography, and ultra-short echo time imaging (PETRA, pointwise encoding time reduction with radial acquisition). All patients underwent computed tomography (CT) angiography before treatment. Thin-section source CT images were correlated with PETRA images. Scan parameters for PETRA were: TR 3.13, TE 0.07, flip angle 6 degrees, 0.83 × 0.83 × 0.83 mm resolution, 3 min 43 s scan time. Two radiologists retrospectively evaluated the visibility of each ossicular structure as positive or negative using PETRA images. The structures evaluated included the head of the malleus, manubrium of the malleus, body of the incus, long process of the incus, and the stapes. Signal intensity of the ossicles was classified as: between labyrinthine fluid and air, similar to labyrinthine fluid, between labyrinthine fluid and cerebellar parenchyma, or higher than cerebellar parenchyma. In all ears, the body of the incus was visible. The head of the malleus was visualized in 36/60 ears. The manubrium of the malleus and long process of the incus was visualized in 1/60 and 4/60 ears, respectively. The stapes were not visualized in any ear. Signal intensity of the visible structures was between labyrinthine fluid and air in all ears. The body of the incus was consistently visualized with intensity between air and labyrinthine fluid on PETRA images in aged subjects. Poor visualization of the manubrium of the malleus, long process of the incus, and the stapes limits clinical significance of middle ear imaging with current PETRA methods.

  3. Pressures in the human cochlea during bone conduction

    NASA Astrophysics Data System (ADS)

    Stieger, Christof; Farahmand, Rosemary B.; Page, Brent F.; Roushan, Kourosh; Merchant, Julie P.; Abur, Defne; Rosowski, John J.; Nakajima, Hideko Heidi

    2015-12-01

    The mechanisms of bone conduction (BC) hearing, which is important in diagnosis and treatment of hearing loss, are poorly understood, thus limiting use of BC. Recently, information gained by intracochlear pressure measurements has revealed that the mechanisms of sound transmission that drive pressure differences across the cochlear partition are different for air conduction (AC) than for round-window stimulation. Presently we are utilizing these pressure measurement techniques in fresh human cadaveric preparations to improve our understanding of sound transmission during BC. We have modified our technique of intracochlear pressure measurements for the special requirements of studying BC, as bone vibration poses challenges for making these measurements. Fiberoptic pressure sensors were inserted through cochleostomies in both scalae at the base of the cochlea. The cochleostomies were then tightly sealed with the sensors in place to prevent air and fluid leaks, and the sensors were firmly secured to ensure uniform vibrations of the sensors and surrounding bone of the cochlea. The velocity of the stapes, round window and cochlear promontory were each measured with laser Doppler vibrometry simultaneous to the intracochlear pressure measurements. To understand the contribution of middle-ear inertia, the incudo-stapedial joint was severed. Subsequently, the stapes footplate was fixed (similar to the consequence of otosclerosis) to determine the effect of removing the mobility of the oval window. BC stimulation resulted in pressure in scala vestibuli that was significantly higher than in scala tympani, such that the differential pressure across the partition - the cochlear drive input - was similar to scala vestibuli pressure (and overall, similar to the relationship found during AC but different than during round-window stimulation). After removing the inertial mass of the middle ear, with only the stapes attached to the flexible oval window, all pressures dropped similarly (10 dB). Fixing the oval window resulted in further drop of all pressures (10 dB more). These decreases in pressure occurred around 1-4 kHz, consistent with clinical observations of Carhart's notch.

  4. Journal of Special Operations Medicine. Volume 2, Edition 1, Winter 2002

    DTIC Science & Technology

    2002-01-01

    regarding clean surgi- cal procedures that an antibiotic treatment regime must be based upon the expected pathogens, appro- priate pharmacokinetic properties...conduction apparatus toDiagram of ear Auricle Epitympanic recess Malleus (head) Incus Crura of stapes Tegmen tympani Cochlear nerve Vesibular nerve Facial...Prominence of lateral semicircular canal Scala vestibuli Cochlear duct containing spiral organ (of Corti) Scala tympaniAuditory (Eustachian) tube Round

  5. The floating mass transducer at the round window: direct transmission or bone conduction?

    PubMed

    Arnold, Andreas; Kompis, Martin; Candreia, Claudia; Pfiffner, Flurin; Häusler, Rudolf; Stieger, Christof

    2010-05-01

    The round window placement of a floating mass transducer (FMT) is a new approach for coupling an implantable hearing system to the cochlea. We evaluated the vibration transfer to the cochlear fluids of an FMT placed at the round window (rwFMT) with special attention to the role of bone conduction. A posterior tympanotomy was performed on eleven ears of seven human whole head specimens. Several rwFMT setups were examined using laser Doppler vibrometry measurements at the stapes and the promontory. In three ears, the vibrations of a bone anchored hearing aid (BAHA) and an FMT fixed to the promontory (pFMT) were compared to explore the role of bone conduction. Vibration transmission to the measuring point at the stapes was best when the rwFMT was perpendicularly placed in the round window and underlayed with connective tissue. Fixation of the rwFMT to the round window exhibited significantly lower vibration transmission. Although measurable, bone conduction from the pFMT was much lower than that of the BAHA. Our results suggest that the rwFMT does not act as a small bone anchored hearing aid, but instead, acts as a direct vibratory stimulator of the round window membrane. Copyright (c) 2009 Elsevier B.V. All rights reserved.

  6. The human otitis media with effusion: a numerical-based study.

    PubMed

    Areias, B; Parente, M P L; Santos, C; Gentil, F; Natal Jorge, R M

    2017-07-01

    Otitis media is a group of inflammatory diseases of the middle ear. Acute otitis media and otitis media with effusion (OME) are its two main types of manifestation. Otitis media is common in children and can result in structural alterations in the middle ear which will lead to hearing losses. This work studies the effects of an OME on the sound transmission from the external auditory meatus to the inner ear. The finite element method was applied on the present biomechanical study. The numerical model used in this work was built based on the geometrical information obtained from The visible ear project. The present work explains the mechanisms by which the presence of fluid in the middle ear affects hearing by calculating the magnitude, phase and reduction of the normalized umbo velocity and also the magnitude and phase of the normalized stapes velocity. A sound pressure level of 90 dB SPL was applied at the tympanic membrane. The harmonic analysis was performed with the auditory frequency varying from 100 Hz to 10 kHz. A decrease in the response of the normalized umbo and stapes velocity as the tympanic cavity was filled with fluid was obtained. The decrease was more accentuated at the umbo.

  7. Human ossicular-joint flexibility transforms the peak amplitude and width of impulsive acoustic stimulia)

    PubMed Central

    Gottlieb, Peter K.; Vaisbuch, Yona

    2018-01-01

    The role of the ossicular joints in the mammalian middle ear is still debated. This work tests the hypothesis that the two synovial joints filter potentially damaging impulsive stimuli by transforming both the peak amplitude and width of these impulses before they reach the cochlea. The three-dimensional (3D) velocity along the ossicular chain in unaltered cadaveric human temporal bones (N = 9), stimulated with acoustic impulses, is measured in the time domain using a Polytec (Waldbronn, Germany) CLV-3D laser Doppler vibrometer. The measurements are repeated after fusing one or both of the ossicular joints with dental cement. Sound transmission is characterized by measuring the amplitude, width, and delay of the impulsive velocity profile as it travels from the eardrum to the cochlea. On average, fusing both ossicular joints causes the stapes velocity amplitude and width to change by a factor of 1.77 (p = 0.0057) and 0.78 (p = 0.011), respectively. Fusing just the incudomalleolar joint has a larger effect on amplitude (a factor of 2.37), while fusing just the incudostapedial joint decreases the stapes velocity on average. The 3D motion of the ossicles is altered by fusing the joints. Finally, the ability of current computational models to predict this behavior is also evaluated.

  8. The effect of static force on round window stimulation with the direct acoustic cochlea stimulator.

    PubMed

    Maier, Hannes; Salcher, Rolf; Schwab, Burkard; Lenarz, Thomas

    2013-07-01

    The Direct Acoustic Cochlea Stimulator Partial Implant (DACS PI, Phonak Acoustic Implants SA, Switzerland) is intended to stimulate the cochlea by a conventional stapedotomy piston that is crimped onto the DACS PI artificial incus. An alternative approach to the round window (RW) is successfully done with other devices, having the advantage of being also independent of the existence of middle ear structure (e.g. ossicles). Here the possibility of stimulating the RW with the DACS actuator is investigated including the impact of static force on sound transmission to the cochlea. The maximum equivalent sound pressure output with RW stimulation was determined experimentally in fresh human temporal bones. Experiments were performed in analogy to the ASTM standard (F2504.24930-1) method for the output determination of implantable middle ear hearing devices (IMEHDs) in human cadaveric temporal bones (TBs). ASTM compliant temporal bones were stimulated with a prosthesis having a spherical tip (∅0.5 mm) attached to the actuator. The stimulation was performed perpendicular to the round window membrane (RWM) at varying position relative to the RW and the resulting static force on the RW membrane was determined. At each position the displacement output of the DACS PI actuator and the stapes footplate (SFP) vibration in response to actuator stimulation was measured with a Laser Doppler Velocimeter (LDV). By comparison of the achieved output at the stapes footplate in response to sound and transducer stimulation the equivalent sound pressure level at the tympanic membrane at 1Vrms input voltage was calculated assuming that the SFP displacement in both conditions is a measure of perceived loudness, as it is done in the ASTM standard. Ten TB preparations within the acceptance range of the ASTM standard were used for analysis. The actuator driven stapes footplate displacement amplitude as well as the resulting equivalent sound pressure level was highly dependent on the static force applied to the RW. The sound transfer efficiency from the RW to the stapes footplate increased monotonically with increasing static load. At a moderate static force load (approx. 3.9 mN) the obtained average sound equivalent sound pressure level was 102-120 eq. dB SPL @ nominally 1Vrms input for frequencies ≤4 kHz. At higher frequencies (6-10 kHz) the achieved output dropped to ∼90 dB SPL. This output was obtained at loading conditions compatible with the actuator safe operating range, although it was possible to increase the output further by increasing the static force load. Our results demonstrate for a first time that static force applied to the RW is crucial for sound transmission efficiency. Further we could show that RW stimulation with the DACS PI actuator is possible having a maximum output that is sufficient to treat moderate and pronounced sensorineural hearing losses (SNHL). This article is part of a Special Issue entitled "MEMRO 2012". Copyright © 2013 Elsevier B.V. All rights reserved.

  9. High Level Impulse Sounds and Human Hearing: Standards, Physiology, Quantification

    DTIC Science & Technology

    2012-05-01

    a result of this change the piston-like movements of the stapes are replaced by a tilting action, which is much less effective in pushing cochlear ...Above this threshold, high noise levels result in a turbulent flow of air through the nonlinear element of the protector, effectively dissipating the...electrical diagrams of earplug and earmuff models (Kalb, 2011). In the model shown, the energy flow through the HPD propagates along three parallel

  10. Does stapes surgery improve tinnitus in patients with otosclerosis?

    PubMed

    Ismi, Onur; Erdogan, Osman; Yesilova, Mesut; Ozcan, Cengiz; Ovla, Didem; Gorur, Kemal

    Otosclerosis (OS) is the primary disease of the human temporal bone characterized by conductive hearing loss and tinnitus. The exact pathogenesis of tinnitus in otosclerosis patients is not known and factors affecting the tinnitus outcome in otosclerosis patients are still controversial. To find the effect of stapedotomy on tinnitus for otosclerosis patients. Fifty-six otosclerosis patients with preoperative tinnitus were enrolled to the study. Pure tone average Air-Bone Gap values, preoperative tinnitus pitch, Air-Bone Gap closure at tinnitus frequencies were evaluated for their effect on the postoperative outcome. Low pitch tinnitus had more favorable outcome compared to high pitch tinnitus (p=0.002). Postoperative average pure tone thresholds Air-Bone Gap values were not related to the postoperative tinnitus (p=0.213). There was no statistically significant difference between postoperative Air-Bone Gap closure at tinnitus frequency and improvement of high pitch tinnitus (p=0.427). There was a statistically significant difference between Air-Bone Gap improvement in tinnitus frequency and low pitch tinnitus recovery (p=0.026). Low pitch tinnitus is more likely to be resolved after stapedotomy for patients with otosclerosis. High pitch tinnitus may not resolve even after closure of the Air-Bone Gap at tinnitus frequencies. Copyright © 2016 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  11. Biomechanical Modeling and Measurement of Blast Injury and Hearing Protection Mechanisms

    DTIC Science & Technology

    2015-10-01

    12 software into Workbench V. 15 in CFX/ANSYS; 2) building the geometry of the ear model with ossicular chain and cochlear load in CFX; 3...the ear canal to middle ear. The model consists of the ear canal, TM, middle ear ossicles and suspensory ligaments, middle ear cavity, and cochlear ...the TM, ossicles, and ligaments/muscle tendons with the cochlear load applied on the stapes footplate. 17 Fig. 21. Time-history plots of

  12. [The influence of the stapes prosthesis on the long-term results of stapedectomy (author's transl)].

    PubMed

    Schöndorf, J; Pilorget, J; Gräber, S

    1980-05-01

    In comparing two groups of patients following stapedectomies, significantly better long-term results were obtained by using the Robinson steel piston prosthesis (n = 85) as opposed to the wire prosthesis (n = 74). By so doing, the impairment of sound transmission was reduced and the Carhart depression counterbalanced. This improvement is thought to result from the increased mass and stability of the steel prosthesis as well as from its more correct anatomical positioning.

  13. Comparison of forward (ear-canal) and reverse (round-window) sound stimulation of the cochlea.

    PubMed

    Stieger, Christof; Rosowski, John J; Nakajima, Hideko Heidi

    2013-07-01

    The cochlea is normally driven with "forward" stimulation, in which sound is introduced to the ear canal. Alternatively, the cochlea can be stimulated at the round window (RW) using an actuator. During RW "reverse" stimulation, the acoustic flow starting at the RW does not necessarily take the same path as during forward stimulation. To understand the differences between forward and reverse stimulation, we measured ear-canal pressure, stapes velocity, RW velocity, and intracochlear pressures in scala vestibuli (SV) and scala tympani (ST) of fresh human temporal bones. During forward stimulation, the cochlear drive (differential pressure across the partition) results from the large difference in magnitude between the pressures of SV and ST, which occurs due to the high compliance of the RW. During reverse stimulation, the relatively high impedance of the middle ear causes the pressures of SV and ST to have similar magnitudes, and the differential pressure results primarily from the difference in phase of the pressures. Furthermore, the sound path differs between forward and reverse stimulation, such that motion through a third window is more significant during reverse stimulation. Additionally, we determined that although stapes velocity is a good estimate of cochlear drive during forward stimulation, it is not a good measure during reverse stimulation. This article is part of a special issue entitled "MEMRO 2012". Copyright © 2012 Elsevier B.V. All rights reserved.

  14. Differential Intracochlear Sound Pressure Measurements in Normal Human Temporal Bones

    NASA Astrophysics Data System (ADS)

    Nakajima, Hideko Heidi; Dong, Wei; Olson, Elizabeth S.; Merchant, Saumil N.; Ravicz, Michael E.; Rosowski, John J.

    2009-02-01

    We present the first simultaneous sound pressure measurements in scala vestibuli and scala tympani of the cochlea in human cadaveric temporal bones. Micro-scale fiberoptic pressure sensors enabled the study of differential sound pressure at the cochlear base. This differential pressure is the input to the cochlear partition, driving cochlear waves and auditory transduction. Results showed that: pressure of scala vestibuli was much greater than scala tympani except at low and high frequencies where scala tympani pressure affects the input to the cochlea; the differential pressure proved to be an excellent measure of normal ossicular transduction of sound (shown to decrease 30-50 dB with ossicular disarticulation, whereas the individual scala pressures were significantly affected by non-ossicular conduction of sound at high frequencies); the middle-ear gain and differential pressure were generally bandpass in frequency dependence; and the middle-ear delay in the human was over twice that of the gerbil. Concurrent stapes velocity measurements allowed determination of the differential impedance across the partition and round-window impedance. The differential impedance was generally resistive, while the round-window impedance was consistent with a compliance in conjunction with distributed inertia and damping. Our techniques can be used to study inner-ear conductive pathologies (e.g., semicircular dehiscence), as well as non-ossicular cochlear stimulation (e.g., round-window stimulation) - situations that cannot be completely quantified by measurements of stapes velocity or scala-vestibuli pressure by themselves.

  15. Experience with the use of a partial ossicular replacement prosthesis with a ball-and-socket joint between the plate and the shaft.

    PubMed

    Birk, Stephanie; Brase, Christoph; Hornung, Joachim

    2014-08-01

    In the further development of alloplastic prostheses for use in middle ear surgery, the Dresden and Cologne University Hospitals, working together with a company, introduced a new partial ossicular replacement prosthesis in 2011. The ball-and-socket joint between the prosthesis and the shaft mimics the natural articulations between the malleus and incus and between the incus and stapes, allowing reaction to movements of the tympanic membrane graft, particularly during the healing process. Retrospective evaluation To reconstruct sound conduction as part of a type III tympanoplasty, partial ossicular replacement prosthesis with a ball-and-socket joint between the plate and the shaft was implanted in 60 patients, with other standard partial ossicular replacement prosthesis implanted in 40 patients and 64 patients. Pure-tone audiometry was carried out, on average, 19 and 213 days after surgery. Results of the partial ossicular replacement prosthesis with a ball-and-socket joint between the plate and the shaft were compared with those of the standard prostheses. Early measurements showed a mean improvement of 3.3 dB in the air-bone gap (ABG) with the partial ossicular replacement prosthesis with a ball-and-socket joint between the plate and the shaft, giving similar results than the standard implants (6.6 and 6.0 dB, respectively), but the differences were not statistically significant. Later measurements showed a statistically significant improvement in the mean ABG, 11.5 dB, compared with 4.4 dB for one of the standard partial ossicular replacement prosthesis and a tendency of better results to 6.9 dB of the other standard prosthesis. In our patients, we achieved similarly good audiometric results to those already published for the partial ossicular replacement prosthesis with a ball-and-socket joint between the plate and the shaft. Intraoperative fixation posed no problems, and the postoperative complication rate was low.

  16. [Computerized study of perioperative difficulties of stapedectomy].

    PubMed

    Cadavid Zink, R; Ballivian, H; Gamboa, F J; Olaizola, F

    1993-01-01

    A retrospective study of 1035 stapedectomies was performed to assess the incidence of intraoperative complications between 1972-1990. We found 45.89% of complications. We divided this alterations in 6 groups: 1) hemorrhage (20.67%), 2) stapes, foot plate, oval window (8.40%), 3) alterations in the middle ear (6.85%), 4) alterations in the incus (3.76%), 5) alterations in the external ear canal (3.57%) and 6) problems with protesis or graf (2.60%). We have analyzed these complications. We propose to carry out the solutions.

  17. Systematic Review of Ossicular Chain Anatomy: Strategic Planning for Development of Novel Middle Ear Prostheses.

    PubMed

    Kamrava, Brandon; Roehm, Pamela C

    2017-08-01

    Objective To systematically review the anatomy of the ossicular chain. Data Sources Google Scholar, PubMed, and otologic textbooks. Review Methods A systematic literature search was performed on January 26, 2015. Search terms used to discover articles consisted of combinations of 2 keywords. One keyword from both groups was used: [ ossicular, ossicle, malleus, incus, stapes] and [ morphology, morphometric, anatomy, variation, physiology], yielding more than 50,000 hits. Articles were then screened by title and abstract if they did not contain information relevant to human ossicular chain anatomy. In addition to this search, references of selected articles were studied as well as suggested relevant articles from publication databases. Standard otologic textbooks were screened using the search criteria. Results Thirty-three sources were selected for use in this review. From these studies, data on the composition, physiology, morphology, and morphometrics were acquired. In addition, any correlations or lack of correlations between features of the ossicular chain and other features of the ossicular chain or patient were noted, with bilateral symmetry between ossicles being the only important correlation reported. Conclusion There was significant variation in all dimensions of each ossicle between individuals, given that degree of variation, custom fitting, or custom manufacturing of prostheses for each patient could optimize prosthesis fit. From published data, an accurate 3-dimensional model of the malleus, incus, and stapes can be created, which can then be further modified for each patient's individual anatomy.

  18. Malleus-to-footplate prosthetic interposition: experience with 265 patients.

    PubMed

    Colletti, V; Fiorino, F G

    1999-03-01

    Absence of the long process of the incus with or without absence of the stapes head accounts for more than 80% of ossicular discontinuities. Total or partial replacement prostheses, made of various materials, are interposed to restore the transfer function of the middle ear. To simplify ossicular reconstruction, reduce operative times and costs, improve functional outcomes, and avoid the risk of infections, we have adopted, during the past 10 years, a technique that makes use of a personally designed alloplastic prosthetic device. The prosthesis connects the malleus to the footplate, even in the presence of the stapes superstructure. This malleus-to-footplate prosthesis consists in a plastipore-coated steel piston and hydroxyapatite head, complete with a groove. The groove is placed beneath the malleus neck after dissection of the tensor tympani tendon and the shaft of the piston on the footplate. Two hundred ninety primary ossiculoplasties with the malleus-to-footplate prostheses were performed in 265 patients from 1986 to 1995 in the ENT Department of the University of Verona. The average postoperative air-bone gap at 0.5 to 3 kHz was 11 dB at 1 year and 14 dB at 5 years. These outcomes are significantly better than those personally obtained previously with ossicular or alloplastic prostheses. No extrusions occurred. The structural characteristics of the malleus-to-foot-plate prosthesis endow the prosthesis with a high degree of biocompatibility and stability and optimal sound-transfer function. The rationale for this particular ossiculoplasty procedure is discussed.

  19. Mice Haploinsufficient for Ets1 and Fli1 Display Middle Ear Abnormalities and Model Aspects of Jacobsen Syndrome.

    PubMed

    Carpinelli, Marina R; Kruse, Elizabeth A; Arhatari, Benedicta D; Debrincat, Marlyse A; Ogier, Jacqueline M; Bories, Jean-Christophe; Kile, Benjamin T; Burt, Rachel A

    2015-07-01

    E26 transformation-specific 1 (ETS1) and friend leukemia integration 1 (FLI1) are members of the ETS family of transcription factors, of which there are 28 in humans. Both genes are hemizygous in Jacobsen syndrome, an 11q contiguous gene deletion disorder involving thrombocytopenia, facial dysmorphism, growth and mental retardation, malformation of the heart and other organs, and hearing impairment associated with recurrent ear infections. To determine whether any of these defects are because of hemizygosity for ETS1 and FLI1, we characterized the phenotype of mice heterozygous for mutant alleles of Ets1 and Fli1. Fli1(+/-) mice displayed mild thrombocytopenia, as did Ets1(+/-)Fli1(+/-) animals. Fli1(+/-) and Ets1(+/-)Fli1(+/-) mice also displayed craniofacial abnormalities, including a small middle ear cavity, short nasal bone, and malformed interface between the nasal bone process and cartilaginous nasal septum. They exhibited hearing impairment, otitis media, fusions of ossicles to the middle ear wall, and deformed stapes. Hearing impairment was more penetrant and stapes malformations were more severe in Ets1(+/-)Fli1(+/-) mice than in Fli1(+/-) mice, indicating partial functional redundancy of these transcription factors during auditory development. Our findings indicate that the short nose, otitis media, and hearing impairment in Jacobsen syndrome are likely because of hemizygosity for ETS1 and FLI1. Copyright © 2015 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.

  20. Rinne revisited: steel versus aluminum tuning forks.

    PubMed

    MacKechnie, Cheryl A; Greenberg, Jesse J; Gerkin, Richard C; McCall, Andrew A; Hirsch, Barry E; Durrant, John D; Raz, Yael

    2013-12-01

    (1) Determine whether tuning fork material (aluminum vs stainless steel) affects Rinne testing in the clinical assessment of conductive hearing loss (CHL). (2) Determine the relative acoustic and mechanical outputs of 512-Hz tuning forks made of aluminum and stainless steel. Prospective, observational. Outpatient otology clinic. Fifty subjects presenting May 2011 to May 2012 with negative or equivocal Rinne in at least 1 ear and same-day audiometry. Rinne test results using aluminum and steel forks were compared and correlated with the audiometric air-bone gap. Bench top measurements using sound-level meter, microphone, and artificial mastoid. Patients with CHL were more likely to produce a negative Rinne test with a steel fork than with an aluminum fork. Logistic regression revealed that the probability of a negative Rinne reached 50% at a 19 dB air-bone gap for stainless steel versus 27 dB with aluminum. Bench top testing revealed that steel forks demonstrate, in effect, more comparable air and bone conduction efficiencies while aluminum forks have relatively lower bone conduction efficiency. We have found that steel tuning forks can detect a lesser air-bone gap compared to aluminum tuning forks. This is substantiated by observations of clear differences in the relative acoustic versus mechanical outputs of steel and aluminum forks, reflecting underlying inevitable differences in acoustic versus mechanical impedances of these devices, and thus efficiency of coupling sound/vibratory energy to the auditory system. These findings have clinical implications for using tuning forks to determine candidacy for stapes surgery.

  1. Intraoperative cone-beam computed tomography and multi-slice computed tomography in temporal bone imaging for surgical treatment.

    PubMed

    Erovic, Boban M; Chan, Harley H L; Daly, Michael J; Pothier, David D; Yu, Eugene; Coulson, Chris; Lai, Philip; Irish, Jonathan C

    2014-01-01

    Conventional computed tomography (CT) imaging is the standard imaging technique for temporal bone diseases, whereas cone-beam CT (CBCT) imaging is a very fast imaging tool with a significant less radiation dose compared with conventional CT. We hypothesize that a system for intraoperative cone-beam CT provides comparable image quality to diagnostic CT for identifying temporal bone anatomical landmarks in cadaveric specimens. Cross-sectional study. University tertiary care facility. Twenty cadaveric temporal bones were affixed into a head phantom and scanned with both a prototype cone-beam CT C-arm and multislice helical CT. Imaging performance was evaluated by 3 otologic surgeons and 1 head and neck radiologist. Participants were presented images in a randomized order and completed landmark identification questionnaires covering 21 structures. CBCT and multislice CT have comparable performance in identifying temporal structures. Three otologic surgeons indicated that CBCT provided statistically equivalent performance for 19 of 21 landmarks, with CBCT superior to CT for the chorda tympani and inferior for the crura of the stapes. Subgroup analysis showed that CBCT performed superiorly for temporal bone structures compared with CT. The radiologist rated CBCT and CT as statistically equivalent for 18 of 21 landmarks, with CT superior to CBCT for the crura of stapes, chorda tympani, and sigmoid sinus. CBCT provides comparable image quality to conventional CT for temporal bone anatomical sites in cadaveric specimens. Clinical applications of low-dose CBCT imaging in surgical planning, intraoperative guidance, and postoperative assessment are promising but require further investigation.

  2. Ear Structures of the Naked Mole-Rat, Heterocephalus glaber, and Its Relatives (Rodentia: Bathyergidae)

    PubMed Central

    Mason, Matthew J.; Cornwall, Hannah L.; Smith, Ewan St. J.

    2016-01-01

    Although increasingly popular as a laboratory species, very little is known about the peripheral auditory system of the naked mole-rat, Heterocephalus glaber. In this study, middle and inner ears of naked mole-rats of a range of ages were examined using micro-computed tomography and dissection. The ears of five other bathyergid species (Bathyergus suillus, Cryptomys hottentotus, Fukomys micklemi, Georychus capensis and Heliophobius argenteocinereus) were examined for comparative purposes. The middle ears of bathyergids show features commonly found in other members of the Ctenohystrica rodent clade, including a fused malleus and incus, a synovial stapedio-vestibular articulation and the loss of the stapedius muscle. Heterocephalus deviates morphologically from the other bathyergids examined in that it has a more complex mastoid cavity structure, poorly-ossified processes of the malleus and incus, a ‘columelliform’ stapes and fewer cochlear turns. Bathyergids have semicircular canals with unusually wide diameters relative to their radii of curvature. How the lateral semicircular canal reaches the vestibule differs between species. Heterocephalus has much more limited high-frequency hearing than would be predicted from its small ear structures. The spongy bone forming its ossicular processes, the weak incudo-stapedial articulation, the columelliform stapes and (compared to other bathyergids) reduced cochlear coiling are all potentially degenerate features which might reflect a lack of selective pressure on its peripheral auditory system. Substantial intraspecific differences were found in certain middle and inner ear structures, which might also result from relaxed selective pressures. However, such interpretations must be treated with caution in the absence of experimental evidence. PMID:27926945

  3. A Preliminary Investigation of the Air-Bone Gap: Changes in Intracochlear Sound Pressure With Air- and Bone-conducted Stimuli After Cochlear Implantation.

    PubMed

    Banakis Hartl, Renee M; Mattingly, Jameson K; Greene, Nathaniel T; Jenkins, Herman A; Cass, Stephen P; Tollin, Daniel J

    2016-10-01

    A cochlear implant electrode within the cochlea contributes to the air-bone gap (ABG) component of postoperative changes in residual hearing after electrode insertion. Preservation of residual hearing after cochlear implantation has gained importance as simultaneous electric-acoustic stimulation allows for improved speech outcomes. Postoperative loss of residual hearing has previously been attributed to sensorineural changes; however, presence of increased postoperative ABG remains unexplained and could result in part from altered cochlear mechanics. Here, we sought to investigate changes to these mechanics via intracochlear pressure measurements before and after electrode implantation to quantify the contribution to postoperative ABG. Human cadaveric heads were implanted with titanium fixtures for bone conduction transducers. Velocities of stapes capitulum and cochlear promontory between the two windows were measured using single-axis laser Doppler vibrometry and fiber-optic sensors measured intracochlear pressures in scala vestibuli and tympani for air- and bone-conducted stimuli before and after cochlear implant electrode insertion through the round window. Intracochlear pressures revealed only slightly reduced responses to air-conducted stimuli consistent with previous literature. No significant changes were noted to bone-conducted stimuli after implantation. Velocities of the stapes capitulum and the cochlear promontory to both stimuli were stable after electrode placement. Presence of a cochlear implant electrode causes alterations in intracochlear sound pressure levels to air, but not bone, conducted stimuli and helps to explain changes in residual hearing noted clinically. These results suggest the possibility of a cochlear conductive component to postoperative changes in hearing sensitivity.

  4. A randomized, blinded study of canal wall up versus canal wall down mastoidectomy determining the differences in viewing middle ear anatomy and pathology.

    PubMed

    Hulka, G F; McElveen, J T

    1998-09-01

    Canal wall down and intact canal wall tympanomastoidectomy represent two surgical approaches to middle ear pathology. The authors hypothesize that there is a difference in the ability to view structures in the middle ear between these two methods. Depending on the individual, many surgeons have used the two different techniques of intact canal wall and canal wall down tympanomastoidectomy for approaching the middle ear. However, opinions conflict as to which approach provides the best visualization of different locations in the middle ear. This study prospectively evaluated temporal bones to determine the differences in visualizing structures of the middle ear using these two approaches. Twelve temporal bones underwent a standardized canal wall down tympanomastoidectomy using a reversible canal wall down technique. All bones were viewed in two dissections: intact canal wall and canal wall down preparations. Four points previously had been marked on each temporal bone in randomly assigned colors. These points include the sinus tympani, posterior crus of stapes, lateral epitympanum, and the Eustachian tube orifice. An observer blinded to the purpose of the study, color, and number of locations recorded the color and location of marks observed within the temporal bones. Randomized bones of two separate settings were viewed such that each bone was viewed in both the canal wall down and the intact canal wall preparations. A significant difference was noted in the ability to observe middle ear pathology between the intact canal wall versus canal wall down tympanomastoidectomy, with the latter showing superiority (p < 0.001). Of the four subsites, the sinus tympani, posterior crus of stapes, and lateral epitympanum were observed more frequently with the canal wall down. There was no significant difference in the ability to observe the Eustachian tube orifice between the two techniques. Statistical analysis shows good reproducibility and randomization of this study. The canal wall down tympanomastoidectomy allowed for superior viewing of the three locations, sinus tympanic, posterior crus of stapes, and lateral at the tympanum, as they were marked in the study. This study shows the potential for improved visualization via the canal wall down tympanomastoidectomy. A significant amount of literature written by individuals and otology group practices is available retrospectively comparing the advantages and disadvantages of intact canal wall versus canal wall down mastoidectomy procedures for approaching middle ear pathology. In the interest of objectively evaluating the differences between these two approaches, we have studied temporal bones in a prospective randomized, blinded study comparing the two. Twelve bones were used and observed twice, once in each of 2 sessions. All bones were viewed in two dissections: intact canal wall and canal wall down mastoidectomy. Four points were marked on each temporal bone in three different colors applied in a randomized order to eliminate observer expectation. The four points marked include sinus tympani, posterior crus of the stapes footplate, lateral epitympanum, and Eustachian tube orifice. Both intact canal wall and canal wall down bones were provided randomly to the observer at each viewing session. Before the observer was allowed to see the dissections, those requiring replacement of the canal for the first session of the study had this done in a method using native posterior bony canal. Temporal bones were presented to an expert otologist in a randomized fashion with each temporal bone being placed in a temporal bone bowl holder and specialized framework, allowing for rotation and repositioning approximating the experience in an operating room setting. For each temporal bone, the observer filled in a questionnaire describing his or her observations by denoting both location and color of marks observed. (ABSTRACT TRUNCATED)

  5. Is Routine Use of High Resolution Computerized Tomography of Temporal Bone in Patients of Atticoantral Chronic Suppurative Otitis Media without Intracranial Complications Justified?

    PubMed

    Bathla, Meeta; Doshi, Hiren; Kansara, Atul

    2018-03-01

    Role of high resolution computerized tomography (HRCT) of temporal bone is established in cases of atticoantral chronic suppurative otitis media (CSOM) with intracranial complications. Routine use of HRCT in management of patients of atticoantral CSOM without intracranial complications has been an issue of debate. The aim of this study was to evaluate the routine use of HRCT of temporal bone in such cases. This study was a prospective study done at LG hospital, AMC MET Medical College, Ahmedabad to evaluate and compare the temporal bone findings in HRCT and intraoperative findings in 100 patients with atticoantral CSOM. All patients underwent HRCT screening followed by surgical exploration of middle ear cleft. In extent of disease HRCT showed very high sensitivity and specificity for epitympanum (100, 94%) and mesotympanum (98, 98%) areas. It gave valuable information of disease extent in hidden areas like sinus tympani and facial recess of mesotympanum. HRCT satisfactorily delineated malleus and incus erosion but had 75% sensitivity for detecting erosion of stapes suprastructure, though specificity was of 97%. For bony anatomical landmarks HRCT showed very high sensitivity and specificity for detecting erosion of lateral semicircular canal, tegmen tympani and sinus plate. Detection of facial canal erosion on HRCT had moderate sensitivity of 75%. We concluded that routine use of HRCT is justified as a reliable preoperative tool in patients with atticoantral CSOM without intracranial complications and it helps to plan type of surgical intervention. HRCT has limited role to distinguish between granulations and cholesteatoma and also to delineate stapes supra structure and facial nerve canal.

  6. Finite element modelling of sound transmission from outer to inner ear.

    PubMed

    Areias, Bruno; Santos, Carla; Natal Jorge, Renato M; Gentil, Fernanda; Parente, Marco Pl

    2016-11-01

    The ear is one of the most complex organs in the human body. Sound is a sequence of pressure waves, which propagates through a compressible media such as air. The pinna concentrates the sound waves into the external auditory meatus. In this canal, the sound is conducted to the tympanic membrane. The tympanic membrane transforms the pressure variations into mechanical displacements, which are then transmitted to the ossicles. The vibration of the stapes footplate creates pressure waves in the fluid inside the cochlea; these pressure waves stimulate the hair cells, generating electrical signals which are sent to the brain through the cochlear nerve, where they are decoded. In this work, a three-dimensional finite element model of the human ear is developed. The model incorporates the tympanic membrane, ossicular bones, part of temporal bone (external auditory meatus and tympanic cavity), middle ear ligaments and tendons, cochlear fluid, skin, ear cartilage, jaw and the air in external auditory meatus and tympanic cavity. Using the finite element method, the magnitude and the phase angle of the umbo and stapes footplate displacement are calculated. Two slightly different models are used: one model takes into consideration the presence of air in the external auditory meatus while the other does not. The middle ear sound transfer function is determined for a stimulus of 60 dB SPL, applied to the outer surface of the air in the external auditory meatus. The obtained results are compared with previously published data in the literature. This study highlights the importance of external auditory meatus in the sound transmission. The pressure gain is calculated for the external auditory meatus.

  7. Auditory ossicles from southwest Asian Mousterian sites.

    PubMed

    Quam, Rolf; Rak, Yoel

    2008-03-01

    The present study describes and analyzes new Neandertal and early modern human auditory ossicles from the sites of Qafzeh and Amud in southwest Asia. Some methodological issues in the measurement of these bones are considered, and a set of standardized measurement protocols is proposed. Evidence of erosive pathological processes, most likely attributed to otitis media, is present on the ossicles of Qafzeh 12 and Amud 7 but none can be detected in the other Qafzeh specimens. Qafzeh 12 and 15 extend the known range of variation in the fossil H. sapiens sample in some metric variables, but morphologically, the new specimens do not differ in any meaningful way from living humans. In most metric dimensions, the Amud 7 incus falls within our modern human range of variation, but the more closed angle between the short and long processes stands out. Morphologically, all the Neandertal incudi described to date show a very straight long process. Several tentative hypotheses can be suggested regarding the evolution of the ear ossicles in the genus Homo. First, the degree of metric and morphological variation seems greater among the fossil H. sapiens sample than in Neandertals. Second, there is a real difference in the size of the malleus between Neandertals and fossil H. sapiens, with Neandertals showing larger values in most dimensions. Third, the wider malleus head implies a larger articular facet in the Neandertals, and this also appears to be reflected in the larger (taller) incus articular facet. Fourth, there is limited evidence for a potential temporal trend toward reduction of the long process within the Neandertal lineage. Fifth, a combination of features in the malleus, incus, and stapes may indicate a slightly different relative positioning of either the tip of the incus long process or stapes footplate within the tympanic cavity in the Neandertal lineage.

  8. A preliminary investigation of the air-bone gap: Changes in intracochlear sound pressure with air- and bone-conducted stimuli after cochlear implantation

    PubMed Central

    Banakis Hartl, Renee M.; Mattingly, Jameson K.; Greene, Nathaniel T.; Jenkins, Herman A.; Cass, Stephen P.; Tollin, Daniel J.

    2016-01-01

    Hypothesis A cochlear implant electrode within the cochlea contributes to the air-bone gap (ABG) component of postoperative changes in residual hearing after electrode insertion. Background Preservation of residual hearing after cochlear implantation has gained importance as simultaneous electric-acoustic stimulation allows for improved speech outcomes. Postoperative loss of residual hearing has previously been attributed to sensorineural changes; however, presence of increased postoperative air-bone gap remains unexplained and could result in part from altered cochlear mechanics. Here, we sought to investigate changes to these mechanics via intracochlear pressure measurements before and after electrode implantation to quantify the contribution to postoperative air-bone gap. Methods Human cadaveric heads were implanted with titanium fixtures for bone conduction transducers. Velocities of stapes capitulum and cochlear promontory between the two windows were measured using single-axis laser Doppler vibrometry and fiber-optic sensors measured intracochlear pressures in scala vestibuli and tympani for air- and bone-conducted stimuli before and after cochlear implant electrode insertion through the round window. Results Intracochlear pressures revealed only slightly reduced responses to air-conducted stimuli consistent with prior literature. No significant changes were noted to bone-conducted stimuli after implantation. Velocities of the stapes capitulum and the cochlear promontory to both stimuli were stable following electrode placement. Conclusion Presence of a cochlear implant electrode causes alterations in intracochlear sound pressure levels to air, but not bone, conducted stimuli and helps to explain changes in residual hearing noted clinically. These results suggest the possibility of a cochlear conductive component to postoperative changes in hearing sensitivity. PMID:27579835

  9. [Observation of bridging operation by an autogenous incus in the ossiculoplasty].

    PubMed

    Li, Hao-zhun; Gong, Shu-sheng

    2008-10-01

    To study the clinical effects of bridging operation by an autogenous incus in the ossiculoplasty. All the postoperative follow-up data of the 68 patients were analyzed retrospectively, who underwent bridging operation by an autogenous incus in the ossiculoplasty and were followed up for 6-28 months with an average of 19.75 months. The autogenous incus which had been reshaped was implanted between the intact malleus and the intact mobile stapes. The preoperative and postoperative pure tone average (PTA) air-conduction, bone-conduction and air-bone gap on four frequencies (0.5, 1, 2 and 4 kHz) were calculated and analyzed. No postoperative autogenous includes were extruded with only two cases displaced. The pure tone air conduction improved from a preoperative average of (46.69 +/- 18.32) dB to a postoperative average of (30.21 +/- 9.46) dB, while bone conduction improved from a preoperative average of (24.72 +/- 10.63) dB to a postoperative average of (18.15 +/- 8.91) dB, as well as air-bone gap closed from a preoperative average of 21.97 +/- 10.32 dB to a postoperative average of (12.06 +/- 9.46) dB. The success rate (postoperative PTA-ABG < or = 20 dB) occurred in 75% of all the cases. The improvement of the bone conduction occurred in 66% of all the cases, at least with 10 dB occurred in at least two frequencies. Because of low expenses, high convenience in an operation, high stability in effects, very low complications and excellent hearing results for the patients, the bridging operation as stated in the above was worthy of choice. The autogenous incus could be utilized if the defects between the intact, mobile stapes and the intact malleus could be well repaired.

  10. Sheep as a large animal ear model: Middle-ear ossicular velocities and intracochlear sound pressure.

    PubMed

    Péus, Dominik; Dobrev, Ivo; Prochazka, Lukas; Thoele, Konrad; Dalbert, Adrian; Boss, Andreas; Newcomb, Nicolas; Probst, Rudolf; Röösli, Christof; Sim, Jae Hoon; Huber, Alexander; Pfiffner, Flurin

    2017-08-01

    Animals are frequently used for the development and testing of new hearing devices. Dimensions of the middle ear and cochlea differ significantly between humans and commonly used animals, such as rodents or cats. The sheep cochlea is anatomically more like the human cochlea in size and number of turns. This study investigated the middle-ear ossicular velocities and intracochlear sound pressure (ICSP) in sheep temporal bones, with the aim of characterizing the sheep as an experimental model for implantable hearing devices. Measurements were made on fresh sheep temporal bones. Velocity responses of the middle ear ossicles at the umbo, long process of the incus and stapes footplate were measured in the frequency range of 0.25-8 kHz using a laser Doppler vibrometer system. Results were normalized by the corresponding sound pressure level in the external ear canal (P EC ). Sequentially, ICSPs at the scala vestibuli and tympani were then recorded with custom MEMS-based hydrophones, while presenting identical acoustic stimuli. The sheep middle ear transmitted most effectively around 4.8 kHz, with a maximum stapes velocity of 0.2 mm/s/Pa. At the same frequency, the ICSP measurements in the scala vestibuli and tympani showed the maximum gain relative to the P EC (24 dB and 5 dB, respectively). The greatest pressure difference across the cochlear partition occurred between 4 and 6 kHz. A comparison between the results of this study and human reference data showed middle-ear resonance and best cochlear sensitivity at higher frequencies in sheep. In summary, sheep can be an appropriate large animal model for research and development of implantable hearing devices. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Mechanics of the Mammalian Cochlea

    PubMed Central

    Robles, Luis; Ruggero, Mario A.

    2013-01-01

    In mammals, environmental sounds stimulate the auditory receptor, the cochlea, via vibrations of the stapes, the innermost of the middle ear ossicles. These vibrations produce displacement waves that travel on the elongated and spirally wound basilar membrane (BM). As they travel, waves grow in amplitude, reaching a maximum and then dying out. The location of maximum BM motion is a function of stimulus frequency, with high-frequency waves being localized to the “base” of the cochlea (near the stapes) and low-frequency waves approaching the “apex” of the cochlea. Thus each cochlear site has a characteristic frequency (CF), to which it responds maximally. BM vibrations produce motion of hair cell stereocilia, which gates stereociliar transduction channels leading to the generation of hair cell receptor potentials and the excitation of afferent auditory nerve fibers. At the base of the cochlea, BM motion exhibits a CF-specific and level-dependent compressive nonlinearity such that responses to low-level, near-CF stimuli are sensitive and sharply frequency-tuned and responses to intense stimuli are insensitive and poorly tuned. The high sensitivity and sharp-frequency tuning, as well as compression and other nonlinearities (two-tone suppression and intermodulation distortion), are highly labile, indicating the presence in normal cochleae of a positive feedback from the organ of Corti, the “cochlear amplifier.” This mechanism involves forces generated by the outer hair cells and controlled, directly or indirectly, by their transduction currents. At the apex of the cochlea, nonlinearities appear to be less prominent than at the base, perhaps implying that the cochlear amplifier plays a lesser role in determining apical mechanical responses to sound. Whether at the base or the apex, the properties of BM vibration adequately account for most frequency-specific properties of the responses to sound of auditory nerve fibers. PMID:11427697

  12. Measurements of Human Middle- and Inner-Ear Mechanics With Dehiscence of the Superior Semicircular Canal

    PubMed Central

    Chien, Wade; Ravicz, Michael E.; Rosowski, John J.; Merchant, Saumil N.

    2008-01-01

    Objectives (1) To develop a cadaveric temporal-bone preparation to study the mechanism of hearing loss resulting from superior semicircular canal dehiscence (SCD) and (2) to assess the potential usefulness of clinical measurements of umbo velocity for the diagnosis of SCD. Background The syndrome of dehiscence of the superior semicircular canal is a clinical condition encompassing a variety of vestibular and auditory symptoms, including an air-bone gap at low frequencies. It has been hypothesized that the dehiscence acts as a “third window” into the inner ear that shunts acoustic energy away from the cochlea at low frequencies, causing hearing loss. Methods Sound-induced stapes, umbo, and round-window velocities were measured in prepared temporal bones (n = 8) using laser-Doppler vibrometry (1) with the superior semicircular canal intact, (2) after creation of a dehiscence in the superior canal, and (3) with the dehiscence patched. Clinical measurements of umbo velocity in live SCD ears (n = 29) were compared with similar data from our cadaveric temporal-bone preparations. Results An SCD caused a significant reduction in sound-induced round-window velocity at low frequencies, small but significant increases in sound-induced stapes and umbo velocities, and a measurable fluid velocity inside the dehiscence. The increase in sound-induced umbo velocity in temporal bones was also found to be similar to that measured in the 29 live ears with SCD. Conclusion Findings from the cadaveric temporal-bone preparation were consistent with the third-window hypothesis. In addition, measurement of umbo velocity in live ears is helpful in distinguishing SCD from other otologic pathologies presenting with an air-bone gap (e.g., otosclerosis). PMID:17255894

  13. Anatomy, Physiology and Function of the Auditory System

    NASA Astrophysics Data System (ADS)

    Kollmeier, Birger

    The human ear consists of the outer ear (pinna or concha, outer ear canal, tympanic membrane), the middle ear (middle ear cavity with the three ossicles malleus, incus and stapes) and the inner ear (cochlea which is connected to the three semicircular canals by the vestibule, which provides the sense of balance). The cochlea is connected to the brain stem via the eighth brain nerve, i.e. the vestibular cochlear nerve or nervus statoacusticus. Subsequently, the acoustical information is processed by the brain at various levels of the auditory system. An overview about the anatomy of the auditory system is provided by Figure 1.

  14. Cerebrospinal fluid otorhinorrhea due to cochlear dysplasias.

    PubMed

    Syal, Rajan; Tyagi, Isha; Goyal, Amit

    2005-07-01

    Cochlear dysplasia associated with defect in stapes footplate can be a cause of cerebrospinal fluid leak. Repair of cerebrospinal fluid leak in these cases is usually done by packing the vestibule with muscle or fascia. This traditional method of repair has 30-60% failure rate. Cerebrospinal fluid leak in four such patients was successfully repaired using multiple layer packing of vestibule, reinforced by pedicle temporalis muscle graft. Intraoperatively continuous lumbar drain was done. Magnetic resonance imaging of inner ear using 3D FSE T2WI and 3D FIESTA sequences was found helpful noninvasive investigation to localize site and route of cerebrospinal fluid leak.

  15. [Techniques of iconographic documentation].

    PubMed

    Motta, G; Valentino, G; Di Lorenzo, G

    1996-04-01

    The Authors describe modalities of photography and videorecording that should be used in stapes surgery and report the solutions they adopted to get iconographic documentation of high quality standard. As regards videorecording systems, the authors used both S-VHS and U-Matic equipment; with both types high fidelity shootings are obtained in the active documentation of each phase of the operation. Moreover, U-Matic master copying guarantees a final copy of higher quality. Technical difficulties that the authors met in videorecording are connected to the restricted field of view, limited by the speculum, which may itself cause dazzling phenomena or light refraction. A 2/3 inch CCD Sony camera, with a modified ELC(Electronic Light Control), was used to get round these problems, so as to eliminate the reflection of surgical instruments. In order to build up a photographic archive, it is also possible to get slides from single pictures of the recorded tapes, although their definition quality is lower than the one obtained foff photos; these, however, must be taken with reference to precise optical parameters and in particular: for shooting view pictures low enlargements (1,6x) were used with an intermediate aperture (f44), while, to better visualize details(footplate hole, stapedial tendon), it was considered right to u se restricted frames (2,5x) and a low aperture (f22). Such a technical solution, in fact, gives a better relation between depth of field and brightness. Finally the Authors underline that the constant use of the intraoperative videorecording system allows: greater participation of every member of the team in the operation; a delayed critical revision of th e operation; medico-legal documentation of possible intraoperative complications; iconographic material available both for scientific and didactic purposes.

  16. Differences in otosclerotic and normal human stapedial osteoblast properties are normalized by alendronate in vitro.

    PubMed

    Gronowicz, Gloria; Richardson, Yvonne L; Flynn, John; Kveton, John; Eisen, Marc; Leonard, Gerald; Aronow, Michael; Rodner, Craig; Parham, Kourosh

    2014-10-01

    Identify and compare phenotypic properties of osteoblasts from patients with otosclerosis (OSO), normal bones (HOB), and normal stapes (NSO) to determine a possible cause for OSO hypermineralization and assess any effects of the bisphosphonate, alendronate. OSO (n = 11), NSO (n = 4), and HOB (n = 13) cultures were assayed for proliferation, adhesion, mineralization, and gene expression with and without 10(-10)M-10(-8)M alendronate. Academic hospital. Cultures were matched for age, sex, and passage number. Cell attachment and proliferation + alendronate were determined by Coulter counting cells and assaying tritiated thymidine uptake, respectively. At 7, 14, and 21 days of culture + alendronate, calcium content and gene expression by quantitative reverse transcription-polymerase chain reaction (qRT-PCR) were determined. OSO had significantly more cells adhere but less proliferation than NSO or HOB. Calcification was significantly increased in OSO compared to HOB and NSO. NSO and HOB had similar cell adhesion and proliferation rates. A dose-dependent effect of alendronate on OSO adhesion, proliferation, and mineralization was found, resulting in levels equal to NSO and HOB. All cultures expressed osteoblast-specific genes such as RUNX2, alkaline phosphatase, type I collagen, and osteocalcin. However, osteopontin was dramatically reduced, 9.4-fold at 14 days, in OSO compared to NSO. Receptor activator of nuclear factor κB ligand/osteoprotegerin (RANKL/OPG), important in bone resorption, was elevated in OSO with decreased levels of OPG levels. Alendronate had little effect on gene expression in HOB but in OSO increased osteopontin levels and decreased RANKL/OPG. OSO cultures displayed properties of hypermineralization due to decreased osteopontin (OPN) and also had increased RANKL/OPG, which were normalized by alendronate. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2014.

  17. Origin of underwater hearing in whales.

    PubMed

    Thewissen, J G; Hussain, S T

    1993-02-04

    All described fossil and Recent cetaceans have relatively similar ear bones (malleus, incus and stapes) that strongly diverge from those of land mammals. Here we report that the hearing organ of the oldest whale, Pakicetus, is the only known intermediate between that of land mammals and aquatic cetaceans (whales, dolphins and porpoises). The incus of Pakicetus is intermediate with respect to inflation, crural proportions, and position of the mallear joint. The incus and mandible of Pakicetus indicate that the path of soundwaves to its ear resembled that of land mammals. These fossils suggest that the first whale was amphibious, and corroborate the hypothesis that artiodactyls (for example, pigs, camels and ruminants) are the closest extant relatives of cetaceans.

  18. The Group Delay and Suppression Pattern of the Cochlear Microphonic Potential Recorded at the Round Window

    PubMed Central

    He, Wenxuan; Porsov, Edward; Kemp, David; Nuttall, Alfred L.; Ren, Tianying

    2012-01-01

    Background It is commonly assumed that the cochlear microphonic potential (CM) recorded from the round window (RW) is generated at the cochlear base. Based on this assumption, the low-frequency RW CM has been measured for evaluating the integrity of mechanoelectrical transduction of outer hair cells at the cochlear base and for studying sound propagation inside the cochlea. However, the group delay and the origin of the low-frequency RW CM have not been demonstrated experimentally. Methodology/Principal Findings This study quantified the intra-cochlear group delay of the RW CM by measuring RW CM and vibrations at the stapes and basilar membrane in gerbils. At low sound levels, the RW CM showed a significant group delay and a nonlinear growth at frequencies below 2 kHz. However, at high sound levels or at frequencies above 2 kHz, the RW CM magnitude increased proportionally with sound pressure, and the CM phase in respect to the stapes showed no significant group delay. After the local application of tetrodotoxin the RW CM below 2 kHz became linear and showed a negligible group delay. In contrast to RW CM phase, the BM vibration measured at location ∼2.5 mm from the base showed high sensitivity, sharp tuning, and nonlinearity with a frequency-dependent group delay. At low or intermediate sound levels, low-frequency RW CMs were suppressed by an additional tone near the probe-tone frequency while, at high sound levels, they were partially suppressed only at high frequencies. Conclusions/Significance We conclude that the group delay of the RW CM provides no temporal information on the wave propagation inside the cochlea, and that significant group delay of low-frequency CMs results from the auditory nerve neurophonic potential. Suppression data demonstrate that the generation site of the low-frequency RW CM shifts from apex to base as the probe-tone level increases. PMID:22470560

  19. Ferromagnetic movements of middle ear implants and stapes prostheses in a 3-T magnetic resonance field.

    PubMed

    Fritsch, Michael H; Gutt, Jason J

    2005-03-01

    A 3-T magnetic resonance field may cause motion or displacement of middle ear implants not seen in studies with 1.5-T magnets. Previous publications have described the safety limitations of some otologic implants in 1.5-T magnetic resonance fields. Several company-wide recalls of implants were issued. No studies to date have been reported for otologic implants within a 3-T magnetic resonance field, nor have there been comparisons with a 1.5-T field strength. Eighteen commonly used middle ear implants and prostheses were selected. In Part 1, the prostheses were placed in Petri dishes and exposed to a 3-T magnetic resonance field. In Part 2, the particular prostheses that showed movement in Part 1 were placed into their intended use positions within temporal bone laboratory specimens and exposed to a 3-T field. Both parts were repeated in a 1.5-T field. In Part 1, three prostheses moved dramatically from their start positions when exposed to the 3-T magnetic resonance field. In Part 2, the three particular prostheses that showed movement in Part 1 showed no gross displacement or movement from their start positions within the temporal bone laboratory specimens. No implants moved in the 1.5-T field in either Part 1 or Part 2. Certain stapes prostheses move dramatically in Petri dishes in 3-T fields. When placed into temporal bone laboratory specimens, the same prostheses show no signs of movement from the surgical site in a 3-T field, and it appears that the surgical position holds the implants firmly in place. Results of published 1.5-T field studies should not be used directly for safety recommendations in a 3-T magnetic resonance. Heat, voltage induction, and vibration during exposure to the magnetic resonance fields should be considered as additional possible safety issues. Preference should be given to platinum and titanium implants in manufacturing processes and surgical selection.

  20. Middle ear dynamics in response to seismic stimuli in the Cape golden mole (Chrysochloris asiatica).

    PubMed

    Willi, U B; Bronner, G N; Narins, P M

    2006-01-01

    The hypertrophied malleus in the middle ear of some golden moles has been assumed to be an adaptation for sensing substrate vibrations by inertial bone conduction, but this has never been conclusively demonstrated. The Cape golden mole (Chrysochloris asiatica) exhibits this anatomical specialization, and the dynamic properties of its middle ear response to vibrations were the subjects of this study. Detailed three-dimensional middle ear anatomy was obtained by x-ray microcomputed tomography (muCT) at a resolution of 12 microm. The ossicular chain exhibits large malleus mass, selective reduction of stiffness and displacement of the center of mass from the suspension points, all favoring low-frequency tuning of the middle ear response. Orientation of the stapes relative to the ossicular chain and the structure of the stapes footplate enable transmission of substrate vibrations arriving from multiple directions to the inner ear. With the long axes of the mallei aligned parallel to the surface, the animal's head was stimulated by a vibration exciter in the vertical and lateral directions over a frequency range from 10 to 600 Hz. The ossicular chain was shown to respond to both vertical and lateral vibrations. Resonant frequencies were found between 71 and 200 Hz and did not differ significantly between the two stimulation directions. Below resonance, the ossicular chain moves in phase with the skull. Near resonance and above, the malleus moves at a significantly larger mean amplitude (5.8+/-2.8 dB) in response to lateral vs vertical stimuli and is 180 degrees out of phase with the skull in both cases. A concise summary of the propagation characteristics of both seismic body (P-waves) and surface (R-waves) is provided. Potential mechanisms by which the animal might exploit the differential response of the ossicular chain to vertical and lateral excitation are discussed in relation to the properties of surface seismic waves.

  1. Perilymph pharmacokinetics of locally-applied gentamicin in the guinea pig.

    PubMed

    Salt, A N; Hartsock, J J; Gill, R M; King, E; Kraus, F B; Plontke, S K

    2016-12-01

    Intratympanic gentamicin therapy is widely used clinically to suppress the vestibular symptoms of Meniere's disease. Dosing in humans was empirically established and we still know remarkably little about where gentamicin enters the inner ear, where it reaches in the inner ear and what time course it follows after local applications. In this study, gentamicin was applied to the round window niche as a 20 μL bolus of 40 mg/ml solution. Ten 2 μL samples of perilymph were collected sequentially from the lateral semi-circular canal (LSCC) at times from 1 to 4 h after application. Gentamicin concentration was typically highest in samples originating from the vestibule and was lower in samples originating from scala tympani. To interpret these results, perilymph elimination kinetics for gentamicin was quantified by loading the entire perilymph space by injection at the LSCC with a 500 μg/ml gentamicin solution followed by sequential perilymph sampling from the LSCC after different delay times. This allowed concentration decline in perilymph to be followed with time. Gentamicin was retained well in scala vestibuli and the vestibule but declined rapidly at the base of scala tympani, dominated by interactions of perilymph with CSF, as reported for other substances. Quantitative analysis, taking into account perilymph kinetics for gentamicin, showed that more gentamicin entered at the round window membrane (57%) than at the stapes (35%) but the lower concentrations found in scala tympani were due to greater losses there. The gentamicin levels found in perilymph of the vestibule, which are higher than would be expected from round window entry alone, undoubtedly contribute to the vestibulotoxic effects of the drug. Furthermore, calculations of gentamicin distribution following targeted applications to the RW or stapes are more consistent with cochleotoxicity depending on the gentamicin concentration in scala vestibuli rather than that in scala tympani. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Impedances of the ear estimated with intracochlear pressures in normal human temporal bones

    NASA Astrophysics Data System (ADS)

    Frear, Darcy; Guan, Xiying; Stieger, Christof; Nakajima, Hideko Heidi

    2018-05-01

    We have measured intracochlear pressures and velocities of stapes and round window (RW) evoked by air conduction (AC) stimulation in many fresh human cadaveric specimens. Our techniques have improved through the years to ensure reliable pressure sensor measurements in the scala vestibuli and scala tympani. Using these measurements, we have calculated impedances of the middle and inner ear (cochlear partition, RW, and physiological leakage impedance in scala vestibuli) to create a lumped element model. Our model simulates our data and allows us to understand the mechanisms involved in air-conducted sound transmission. In the future this model will be used as a tool to understand transmission mechanisms of various stimuli and to help create more sophisticated models of the ear.

  3. The Envoy® Totally Implantable Hearing System, St. Croix Medical

    PubMed Central

    Kroll, Kai; Grant, Iain L.; Javel, Eric

    2002-01-01

    The Totally Implantable Envoy® System is currently undergoing clinical trials in both the United States and Europe. The fully implantable hearing device is intended for use in patients with sensorineural hearing loss. The device employs piezoelectric transducers to sense ossicle motion and drive the stapes. Programmable signal processing parameters include amplification, compression, and variable frequency response. The fully implantable attribute allows users to take advantage of normal external ear resonances and head-related transfer functions, while avoiding undesirable earmold effects. The high sensitivity, low power consumption, and high fidelity attributes of piezoelectric transducers minimize acoustic feedback and maximize battery life (Gyo, 1996; Yanagihara, (1987) and 2001). The surgical procedure to install the device has been accurately defined and implantation is reversible. PMID:25425915

  4. Hook Region Represented in a Cochlear Model

    NASA Astrophysics Data System (ADS)

    Steele, Charles R.; Kim, Namkeun; Puria, Sunil

    2009-02-01

    The present interest is in discontinuities. Particularly the geometry of the hook region, with the flexible round window nearly parallel with the basilar membrane, is not represented by a standard box model, in which both stapes and round window are placed at the end. A better model represents the round window by a soft membrane in the wall of scala tympani, with the end closed. This complicates the analysis considerably. Features are that the significant compression wave, i.e., the fast wave, is of negligible magnitude in this region, and that significant evanescent waves occur because of the discontinuities at the beginning and end of the simulated round window. The effect of this on both high frequency, with maximum basilar membrane response in the hook region, and lower frequencies are determined.

  5. CT scans and 3D reconstructions of Florida manatee (Trichechus manatus latirostris) heads and ear bones.

    PubMed

    Chapla, Marie E; Nowacek, Douglas P; Rommel, Sentiel A; Sadler, Valerie M

    2007-06-01

    The auditory anatomy of the Florida manatee (Trichechus manatus latirostris) was investigated using computerized tomography (CT), three-dimensional reconstructions, and traditional dissection of heads removed during necropsy. The densities (kg/m3) of the soft tissues of the head were measured directly using the displacement method and those of the soft tissues and bone were calculated from CT measurements (Hounsfield units). The manatee's fatty tissue was significantly less dense than the other soft tissues within the head (p<0.05). The squamosal bone was significantly less dense than the other bones of the head (p<0.05). Measurements of the ear bones (tympanic, periotic, malleus, incus, and stapes) collected during dissection revealed that the ossicular chain was overly massive for the mass of the tympanoperiotic complex.

  6. Correlation between Preoperative High Resolution Computed Tomography (CT) Findings with Surgical Findings in Chronic Otitis Media (COM) Squamosal Type.

    PubMed

    Karki, S; Pokharel, M; Suwal, S; Poudel, R

    Background The exact role of High resolution computed tomography (HRCT) temporal bone in preoperative assessment of Chronic suppurative otitis media atticoantral disease still remains controversial. Objective To evaluate the role of high resolution computed tomography temporal bone in Chronic suppurative otitis media atticoantral disease and to compare preoperative computed tomographic findings with intra-operative findings. Method Prospective, analytical study conducted among 65 patients with chronic suppurative otitis media atticoantral disease in Department of Radiodiagnosis, Kathmandu University Dhulikhel Hospital between January 2015 to July 2016. The operative findings were compared with results of imaging. The parameters of comparison were erosion of ossicles, scutum, facial canal, lateral semicircular canal, sigmoid and tegmen plate along with extension of disease to sinus tympani and facial recess. Sensitivity, specificity, negative predictive value, positive predictive values were calculated. Result High resolution computed tomography temporal bone offered sensitivity (Se) and specificity (Sp) of 100% for visualization of sigmoid and tegmen plate erosion. The performance of HRCT in detecting malleus (Se=100%, Sp=95.23%), incus (Se=100%,Sp=80.48%) and stapes (Se=96.55%, Sp=71.42%) erosion was excellent. It offered precise information about facial canal erosion (Se=100%, Sp=75%), scutum erosion (Se=100%, Sp=96.87%) and extension of disease to facial recess and sinus tympani (Se=83.33%,Sp=100%). high resolution computed tomography showed specificity of 100% for lateral semicircular canal erosion (Sp=100%) but with low sensitivity (Se=53.84%). Conclusion The findings of high resolution computed tomography and intra-operative findings were well comparable except for lateral semicircular canal erosion. high resolution computed tomography temporal bone acts as a road map for surgeon to identify the extent of disease, plan for appropriate procedure that is required and prepare for potential complications that can be encountered during surgery.

  7. Response Changes During Insertion of a Cochlear Implant Using Extracochlear Electrocochleography.

    PubMed

    Giardina, Christopher K; Khan, Tatyana E; Pulver, Stephen H; Adunka, Oliver F; Buchman, Craig A; Brown, Kevin D; Pillsbury, Harold C; Fitzpatrick, Douglas C

    2018-03-16

    Electrocochleography is increasingly being utilized as an intraoperative monitor of cochlear function during cochlear implantation (CI). Intracochlear recordings from the advancing electrode can be obtained through the device by on-board capabilities. However, such recordings may not be ideal as a monitor because the recording electrode moves in relation to the neural and hair cell generators producing the responses. The purposes of this study were to compare two extracochlear recording locations in terms of signal strength and feasibility as intraoperative monitoring sites and to characterize changes in cochlear physiology during CI insertion. In 83 human subjects, responses to 90 dB nHL tone bursts were recorded both at the round window (RW) and then at an extracochlear position-either adjacent to the stapes or on the promontory just superior to the RW. Recording from the fixed, extracochlear position continued during insertion of the CI in 63 cases. Before CI insertion, responses to low-frequency tones at the RW were roughly 6 dB larger than when recording at either extracochlear site, but the two extracochlear sites did not differ from one another. During CI insertion, response losses from the promontory or adjacent to the stapes stayed within 5 dB in ≈61% (38/63) of cases, presumably indicating atraumatic insertions. Among responses which dropped more than 5 dB at any time during CI insertion, 12 subjects showed no response recovery, while in 13, the drop was followed by partial or complete response recovery by the end of CI insertion. In cases with recovery, the drop in response occurred relatively early (<15 mm insertion) compared to those where there was no recovery. Changes in response phase during the insertion occurred in some cases; these may indicate a change in the distributions of generators contributing to the response. Monitoring the electrocochleography during CI insertion from an extracochlear site reveals insertions that are potentially atraumatic show interaction with cochlear structures followed by response recovery or show interactions such that response losses persist to the end of recording.

  8. Round Window Membrane Implantation with an Active Middle Ear Implant: A Study of the Effects on the Performance of Round Window Exposure and Transducer Tip Diameter in Human Cadaveric Temporal Bones

    PubMed Central

    Tringali, Stéphane; Koka, Kanthaiah; Deveze, Arnaud; Holland, N. Julian; Jenkins, Herman A.; Tollin, Daniel J.

    2010-01-01

    Objectives To assess the importance of 2 variables, transducer tip diameter and resection of the round window (RW) niche, affecting the optimization of the mechanical stimulation of the RW membrane with an active middle ear implant (AMEI). Materials and Methods: Ten temporal bones were prepared with combined atticotomy and facial recess approach to expose the RW. An AMEI stimulated the RW with 2 ball tip diameters (0.5 and 1.0 mm) before and after the resection of the bony rim of the RW niche. The RW drive performance, assessed by stapes velocities using laser Doppler velocimetry, was analyzed in 3 frequency ranges: low (0.25–1 kHz), medium (1–3 kHz) and high (3–8 kHz). Results Driving the RW produced mean peak stapes velocities (HEV) of 0.305 and 0.255 mm/s/V at 3.03 kHz, respectively, for the 1- and 0.5-mm tips, with the RW niche intact. Niche drilling increased the HEV to 0.73 and 0.832 mm/s/V for the 1- and 0.5-mm tips, respectively. The tip diameter produced no difference in output at low and medium frequencies; however, the 0.5-mm tip was 5 and 6 dB better than the 1-mm tip at high frequencies before and after niche drilling, respectively. Drilling the niche significantly improved the output by 4 dB at high frequencies for the 1-mm tip, and by 6 and 10 dB in the medium- and high-frequency ranges for the 0.5-mm tip. Conclusion The AMEI was able to successfully drive the RW membrane in cadaveric temporal bones using a classical facial recess approach. Stimulation of the RW membrane with an AMEI without drilling the niche is sufficient for successful hearing outputs. However, the resection of the bony rim of the RW niche significantly improved the RW stimulation at medium and higher frequencies. Drilling the niche enhances the exposure of the RW membrane and facilitates positioning the implant tip. PMID:20150727

  9. Hearing results using the SMart piston prosthesis.

    PubMed

    Fayad, Jose N; Semaan, Maroun T; Meier, Josh C; House, John W

    2009-12-01

    SMart, a newly introduced piston prosthesis for stapedotomy, is a nitinol-based, heat-activated, self-crimping prosthesis. We review our hearing results and postoperative complications using this self-crimped piston prosthesis and compare them with those obtained using stainless steel or platinum piston prostheses. Audiometric results using the SMart piston are identical to those obtained using a conventional piston prosthesis. Retrospective chart review. Private neurotologic tertiary referral center. The 416 ears reviewed included 306 with a SMart prosthesis and 110 conventional prostheses. 61% were women. Mean follow-up time was 5.6 (standard deviation [SD], 6.3 mo) and 6.9 months (SD, 7.0 mo) for the 2 groups, respectively. Stapedotomy using the SMart or a conventional (non-SMart) prosthesis. Audiometric hearing results, including pure-tone average (PTA) and air-bone gap (ABG), and prevalence of postoperative complications. Mean postoperative PTA was 32.6 (SD, 16.8) dB for the SMart group and 29.4 (SD, 13.5) dB for the non-SMart group, with ABGs of 7.6 (SD, 8.9) and 6.0 (SD, 5.2) dB, respectively. Mean change (decrease) in ABG was 18.7 (SD, 13.1) dB for the SMart group and 19.9 (SD, 10.3) dB for the non-SMart group. High-frequency bone PTAs showed overclosure of 2.0 (SD, 7.9) dB for the SMart group and 3.6 (SD, 8.6) dB for the non-SMart group. Postoperative vertigo and tinnitus were infrequent. No significant differences in these audiometric outcomes or complication rates were noted between groups. There was no significant difference in rate of gap closure to within 10 dB (78.3 versus 84.2%, SMart and non-SMart, respectively) or 20 dB (94.2 and 98.0%). Compared with conventional stapes prostheses, the nitinol-based SMart is a safe and reliable stapes prosthesis that eliminates manual crimping without significantly altering the audiometric outcome. Complications are rare, but longer follow-up is needed before establishing long-term stability.

  10. Cochlear implantation using a custom guide catheter in fourteen patients with incomplete partition type III.

    PubMed

    Tian, Hao; Wang, Line; Gao, Fenqi; Liang, Wenqi; Peng, Kevin A

    2018-05-22

    Incomplete partition type III (IP-III), also termed X-linked deafness with stapes gusher, is a heterogeneous condition that predominantly affects males; however, females demonstrating the phenotype also exist. The absence of a bony partition between the fundus of the internal auditory canal (IAC) and cochlea predisposes these patients to cerebrospinal fluid leak or electrode passage into the IAC when performing cochlear implantation. We describe a surgeon-fabricated guide catheter, made intraoperatively from a 16-gauge intravenous catheter, that helps avoid electrode passage into the IAC during CI for patients with IP-III. Acceptable cochlear implant outcomes were attainable in IP-III patients, but these patients scored worse than matched CI patients with normal inner ear structures. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  11. The Lenticular Process of the Incus

    PubMed Central

    Graboyes, Evan M.; Hullar, Timothy E.; Chole, Richard A.

    2011-01-01

    17th century anatomists, including Franciscus Sylvius, identified a small bony structure between the distal end of the incus and the stapes that they believed was a separate and thus additional ossicle. The existence of the ossicle at the distal portion of the long process of the incus was controversial for the next two hundred years. In the 19th century, anatomists including Johann Friedrich Blumenbach, Henry Jones Shrapnell, Eduard Hagenbach, and Joseph Hyrtl provided numerous arguments to demonstrate why the so-called additional ossicle was actually attached to the incus by a thin strut, and thus not a separate bone. Since then, the ovoid end of the incus has been referred to as the “lenticular process” of the incus. The best nomenclature for the bony connection between the lenticular process and the rest of the incus remains uncertain, but the term “lenticular process” should not include its connecting pedicle. PMID:21986927

  12. Influence of the middle ear anatomy on the performance of a membrane sensor in the incudostapedial joint gap.

    PubMed

    Koch, Martin; Seidler, Hannes; Hellmuth, Alexander; Bornitz, Matthias; Lasurashvili, Nikoloz; Zahnert, Thomas

    2013-07-01

    There is a great demand for implantable microphones for future generations of implantable hearing aids, especially Cochlea Implants. An implantable middle ear microphone based on a piezoelectric membrane sensor for insertion into the incudostapedial gap is investigated. The sensor is designed to measure the sound-induced forces acting on the center of the membrane. The sensor mechanically couples to the adjacent ossicles via two contact areas, the sensor membrane and the sensor housing. The sensing element is a piezoelectric single crystal bonded on a titanium membrane. The sensor allows a minimally invasive and reversible implantation without removal of ossicles and without additional sensor fixation in the tympanic cavity. This study investigates the implantable microphone sensor and its implantation concept. It intends to quantify the influence of the sensor's insertion position on the achievable microphone sensitivity. The investigation considers anatomical and pathological variations of the middle ear geometry and its space limitations. Temporal bone experiments on a laboratory model show that anatomical and pathological variations of the middle ear geometry can prevent the sensor from being placed optimally within the incudostapedial joint. Beyond scattering of transfer functions due to anatomic variations of individual middle ears there is the impact of variations in the sensor position within the ossicular chain that has a considerable effect on the transfer characteristics of the middle ear microphone. The centering of the sensor between incus and stapes, the direction of insertion (membrane to stapes or to incus) and the effect of additional contact points with surrounding anatomic structures affect the signal yield of the implanted sensor. The presence of additional contact points has a considerably impact on the sensitivity, yet the microphone sensitivity is quite robust against small changes in the positioning of the incus on the sensor. Signal losses can be avoided by adjusting the position of the sensor within the joint. The findings allow the development of an improved surgical insertion technique to ensure maximally achievable signal yield of the membrane sensor in the ISJ and provides valuable knowledge for a future design considerations including sensor miniaturization and geometry. Measurements of the implanted sensor in temporal bone specimens showed a microphone sensitivity in the order of 1 mV/Pa. This article is part of a special issue entitled "MEMRO 2012". Copyright © 2012 Elsevier B.V. All rights reserved.

  13. Intracochlear pressure measurements to study bone conduction transmission: State-of-the art and proof of concept of the experimental Procedure

    NASA Astrophysics Data System (ADS)

    Borgers, Charlotte; van Wieringen, Astrid; D'hondt, Christiane; Verhaert, Nicolas

    2018-05-01

    The cochlea is the main contributor in bone conduction perception. Measurements of differential pressure in the cochlea give a good estimation of the cochlear input provided by bone conduction stimulation. Recent studies have proven the feasibility of intracochlear pressure measurements in chinchillas and in human temporal bones to study bone conduction. However, similar measurements in fresh-frozen whole human cadaveric heads could give a more realistic representation of the five different transmission pathways of bone conduction to the cochlea compared to human temporal bones. The aim of our study is to develop and validate a framework for intracochlear pressure measurements to evaluate different aspects of bone conduction in whole human cadaveric heads. A proof of concept describing our experimental setup is provided together with the procedure. Additionally, we also present a method to fix the stapes footplate in order to simulate otosclerosis in human temporal bones. The effectiveness of this method is verified by some preliminary results.

  14. Mechanics and materials in middle ear reconstruction.

    PubMed

    Lesser, T H; Williams, K R; Blayney, A W

    1991-02-01

    The normal anatomy and physiology of the middle ear is not reproduced in ossiculoplasty and an artificial mechanism for the transmission of sound results. This is true for all types of graft, be they of natural or man-made material. There are, therefore, 2 areas for consideration when looking at the problems encountered in such reconstructions: first, the materials' biocompatability and, secondly, the mechanical effects of the positioning of the graft in the reconstructed ossicular chain. The present work examines these mechanical effects using the finite element method to determine stress and displacement levels in the reconstructed ossicular chain. It is found that the stress levels at the implant-stapedial joint increases as the implant is gradually moved down the malleus. In contrast there is thought to be an increase in sound transmission as the implant is moved down the malleus. Changes in rigidity and hardness of the implant appear to make only modest stress attenuations at the implant-stapes interface.

  15. The use of a small fenestra technique with the Fisch piston in the surgical treatment of otosclerosis.

    PubMed

    Pedersen, C B

    1987-06-01

    The modern surgical treatment of otosclerosis consists of replacement of the sound conducting function of the stapes by a prosthesis. The results obtained in 100 consecutive patients using the small fenestra technique and a 0.4 mm. Teflon and steel wire prosthesis are reported. The surgical technique is described. The hearing was improved in all patients. In 92 per cent of the patients an optimal hearing gain was found after an observation time of 1 to 4 years. Five patients required re-operation during the observation time. The small fenestra technique and the Fisch prosthesis were considered optimal in respect to technical difficulty, hearing improvement and complication rate. There was no sensorineural hearing loss in this series of patients. The absence of serious complications makes it reasonable to operate on both ears in patients with bilateral hearing loss. The results are as good in elderly people as in younger people. Therefore the operation can be offered for patients in all age groups.

  16. Atypical incus necrosis: a case report and literature review.

    PubMed

    Choudhury, N; Kumar, G; Krishnan, M; Gatland, D J

    2008-10-01

    We report an atypical case of ossicular necrosis affecting the incus, in the absence of any history of chronic serous otitis media. We also discuss the current theories of incus necrosis. A male patient presented with a history of right unilateral hearing loss and tinnitus. Audiometry confirmed right conductive deafness; tympanometry was normal bilaterally. He underwent a right exploratory tympanotomy, which revealed atypical erosion of the proximal long process of the incus. Middle-ear examination was otherwise normal, with a mobile stapes footplate. The redundant long process of the incus was excised and a partial ossicular replacement prosthesis was inserted, resulting in improved hearing. Ossicular pathologies most commonly affect the incus. The commonest defect is an absent lenticular and distal long process of the incus, which is most commonly associated with chronic otitis media. This is the first reported case of ossicular necrosis, particularly of the proximal long process of the incus, in the absence of chronic middle-ear pathology.

  17. Can you hear me now? Understanding vertebrate middle ear development

    PubMed Central

    Chapman, Susan Caroline

    2010-01-01

    The middle ear is a composite organ formed from all three germ layers and the neural crest. It provides the link between the outside world and the inner ear, where sound is transduced and routed to the brain for processing. Extensive classical and modern studies have described the complex morphology and origin of the middle ear. Non-mammalian vertebrates have a single ossicle, the columella. Mammals have three functionally equivalent ossicles, designated the malleus, incus and stapes. In this review, I focus on the role of genes known to function in the middle ear. Genetic studies are beginning to unravel the induction and patterning of the multiple middle ear elements including the tympanum, skeletal elements, the air-filled cavity, and the insertion point into the inner ear oval window. Future studies that elucidate the integrated spatio-temporal signaling mechanisms required to pattern the middle ear organ system are needed. The longer-term translational benefits of understanding normal and abnormal ear development will have a direct impact on human health outcomes. PMID:21196256

  18. A mechano-acoustic model of the effect of superior canal dehiscence on hearing in chinchilla

    PubMed Central

    Songer, Jocelyn E.; Rosowski, John J.

    2008-01-01

    Superior canal dehiscence (SCD) is a pathological condition of the ear that can cause a conductive hearing loss. The effect of SCD (a hole in the bony wall of the superior semicircular canal) on chinchilla middle- and inner-ear mechanics is analyzed with a circuit model of the dehiscence. The model is used to predict the effect of dehiscence on auditory sensitivity and mechanics. These predictions are compared to previously published measurements of dehiscence related changes in chinchilla cochlear potential, middle-ear input admittance and stapes velocity. The comparisons show that the model predictions are both qualitatively and quantitatively similar to the physiological results for frequencies where physiologic data are available. The similarity supports the third-window hypothesis of the effect of superior canal dehiscence on auditory sensitivity and mechanics and provides the groundwork for the development of a model that predicts the effect of superior canal dehiscence syndrome on auditory sensitivity and mechanics in humans. PMID:17672643

  19. Evolution of the auditory ossicles in extant hominids: metric variation in African apes and humans.

    PubMed

    Quam, Rolf M; Coleman, Mark N; Martínez, Ignacio

    2014-08-01

    The auditory ossicles in primates have proven to be a reliable source of phylogenetic information. Nevertheless, to date, very little data have been published on the metric dimensions of the ear ossicles in African apes and humans. The present study relies on the largest samples of African ape ear ossicles studied to date to address questions of taxonomic differences and the evolutionary transformation of the ossicles in gorillas, chimpanzees and humans. Both African ape taxa show a malleus that is characterized by a long and slender manubrium and relatively short corpus, whereas humans show the opposite constellation of a short and thick manubrium and relatively long corpus. These changes in the manubrium are plausibly linked with changes in the size of the tympanic membrane. The main difference between the incus in African apes and humans seems to be related to changes in the functional length. Compared with chimpanzees, human incudes are larger in nearly all dimensions, except articular facet height, and show a more open angle between the axes. The gorilla incus resembles humans more closely in its metric dimensions, including functional length, perhaps as a result of the dramatically larger body size compared with chimpanzees. The differences between the stapedes of humans and African apes are primarily size-related, with humans being larger in nearly all dimensions. Nevertheless, some distinctions between the African apes were found in the obturator foramen and head height. Although correlations between metric variables in different ossicles were generally lower than those between variables in the same bone, variables of the malleus/incus complex appear to be more strongly correlated than those of the incus/stapes complex, perhaps reflecting the different embryological and evolutionary origins of the ossicles. The middle ear lever ratio for the African apes is similar to other haplorhines, but humans show the lowest lever ratio within primates. Very low levels of sexual dimorphism were found in the ossicles within each taxon, but some relationship with body size and several dimensions of the ear bones was found. Several of the metric distinctions in the incus and stapes imply a slightly different articulation of the ossicular chain within the tympanic cavity in African apes compared with humans. The limited auditory implications of these metric differences in the ossicles are also discussed. Finally, the results of this study suggest that several plesiomorphic features for apes may be retained in the ear bones of the early hominin taxa Australopithecus and Paranthropus as well as in the Neandertals. © 2014 Anatomical Society.

  20. Evolution of the auditory ossicles in extant hominids: metric variation in African apes and humans

    PubMed Central

    Quam, Rolf M; Coleman, Mark N; Martínez, Ignacio

    2014-01-01

    The auditory ossicles in primates have proven to be a reliable source of phylogenetic information. Nevertheless, to date, very little data have been published on the metric dimensions of the ear ossicles in African apes and humans. The present study relies on the largest samples of African ape ear ossicles studied to date to address questions of taxonomic differences and the evolutionary transformation of the ossicles in gorillas, chimpanzees and humans. Both African ape taxa show a malleus that is characterized by a long and slender manubrium and relatively short corpus, whereas humans show the opposite constellation of a short and thick manubrium and relatively long corpus. These changes in the manubrium are plausibly linked with changes in the size of the tympanic membrane. The main difference between the incus in African apes and humans seems to be related to changes in the functional length. Compared with chimpanzees, human incudes are larger in nearly all dimensions, except articular facet height, and show a more open angle between the axes. The gorilla incus resembles humans more closely in its metric dimensions, including functional length, perhaps as a result of the dramatically larger body size compared with chimpanzees. The differences between the stapedes of humans and African apes are primarily size-related, with humans being larger in nearly all dimensions. Nevertheless, some distinctions between the African apes were found in the obturator foramen and head height. Although correlations between metric variables in different ossicles were generally lower than those between variables in the same bone, variables of the malleus/incus complex appear to be more strongly correlated than those of the incus/stapes complex, perhaps reflecting the different embryological and evolutionary origins of the ossicles. The middle ear lever ratio for the African apes is similar to other haplorhines, but humans show the lowest lever ratio within primates. Very low levels of sexual dimorphism were found in the ossicles within each taxon, but some relationship with body size and several dimensions of the ear bones was found. Several of the metric distinctions in the incus and stapes imply a slightly different articulation of the ossicular chain within the tympanic cavity in African apes compared with humans. The limited auditory implications of these metric differences in the ossicles are also discussed. Finally, the results of this study suggest that several plesiomorphic features for apes may be retained in the ear bones of the early hominin taxa Australopithecus and Paranthropus as well as in the Neandertals. PMID:24845949

  1. Acoustic stimulation on the round window for active middle ear implants.

    PubMed

    Seong, Kiwoong; Lee, Kyuyup; Puria, Sunil; Cho, Jin-Ho

    2018-06-01

    Many clinical reports have discussed the effectiveness of stimulating the ear's round window (RW) with a tool to mitigate conductive and mixed hearing loss. The RW is one of the two openings from the middle ear into the inner ear. Various methods have been proposed to construct a highly efficient, easily implanted, and reliable RW transducer. Devices, however, such as floating mass transducers, have difficulty establishing proper contact without some degree of bone incision around the RW. Additionally, vibration energy may not be fully transmitted to the cochlea, but instead will be spread through the soft tissue around the transducer. We propose a more direct RW stimulation with very high acoustical impedance using a receiver that is a volume velocity source. We expect this source to overcome large acoustic impedance by maximizing sound pressure in a confined space, the RW niche. To verify the effectiveness of the proposed method, ear canal pressure, RW pressure, and stapes velocity are measured by acoustic RW stimulation of human temporal bones. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. Finite element modeling of sound transmission with perforations of tympanic membrane

    PubMed Central

    Gan, Rong Z.; Cheng, Tao; Dai, Chenkai; Yang, Fan; Wood, Mark W.

    2009-01-01

    A three-dimensional finite element (FE) model of human ear with structures of the external ear canal, middle ear, and cochlea has been developed recently. In this paper, the FE model was used to predict the effect of tympanic membrane (TM) perforations on sound transmission through the middle ear. Two perforations were made in the posterior-inferior quadrant and inferior site of the TM in the model with areas of 1.33 and 0.82 mm2, respectively. These perforations were also created in human temporal bones with the same size and location. The vibrations of the TM (umbo) and stapes footplate were calculated from the model and measured from the temporal bones using laser Doppler vibrometers. The sound pressure in the middle ear cavity was derived from the model and measured from the bones. The results demonstrate that the TM perforations can be simulated in the FE model with geometrical visualization. The FE model provides reasonable predictions on effects of perforation size and location on middle ear transfer function. The middle ear structure-function relationship can be revealed with multi-field coupled FE analysis. PMID:19603881

  3. A validated methodology for the 3D reconstruction of cochlea geometries using human microCT images

    NASA Astrophysics Data System (ADS)

    Sakellarios, A. I.; Tachos, N. S.; Rigas, G.; Bibas, T.; Ni, G.; Böhnke, F.; Fotiadis, D. I.

    2017-05-01

    Accurate reconstruction of the inner ear is a prerequisite for the modelling and understanding of the inner ear mechanics. In this study, we present a semi-automated methodology for accurate reconstruction of the major inner ear structures (scalae, basilar membrane, stapes and semicircular canals). For this purpose, high resolution microCT images of a human specimen were used. The segmentation methodology is based on an iterative level set algorithm which provides the borders of the structures of interest. An enhanced coupled level set method which allows the simultaneous multiple image labeling without any overlapping regions has been developed for this purpose. The marching cube algorithm was applied in order to extract the surface from the segmented volume. The reconstructed geometries are then post-processed to improve the basilar membrane geometry to realistically represent physiologic dimensions. The final reconstructed model is compared to the available data from the literature. The results show that our generated inner ear structures are in good agreement with the published ones, while our approach is the most realistic in terms of the basilar membrane thickness and width reconstruction.

  4. The Effect of Superior Semicircular Canal Dehiscence on Intracochlear Sound Pressures

    NASA Astrophysics Data System (ADS)

    Nakajima, Hideko Heidi; Pisano, Dominic V.; Merchant, Saumil N.; Rosowski, John J.

    2011-11-01

    Semicircular canal dehiscence (SCD) is a pathological opening in the bony wall of the inner ear that can result in conductive hearing loss. The hearing loss is variable across patients, and the precise mechanism and source of variability is not fully understood. We use intracochlear sound pressure measurements in cadaveric preparations to study the effects of SCD size. Simultaneous measurement of basal intracochlear sound pressures in scala vestibuli (SV) and scala tympani (ST) quantifies the complex differential pressure across the cochlear partition, the stimulus that excites the partition. Sound-induced pressures in SV and ST, as well as stapes velocity and ear-canal pressure are measured simultaneously for various sizes of SCD followed by SCD patching. At low frequencies (<600 Hz) our results show that SCD decreases the pressure in both SV and ST, as well as differential pressure, and these effects become more pronounced as dehiscence size is increased. For frequencies above 1 kHz, the smallest pinpoint dehiscence can have the larger effect on the differential pressure in some ears. These effects due to SCD are reversible by patching the dehiscence.

  5. Modeling Electrically Evoked Otoacoustic Emissions

    NASA Astrophysics Data System (ADS)

    Grosh, K.; Deo, N.; Parthasarathi, A. A.; Nuttall, A. L.; Zheng, J. F.; Ren, T. Y.

    2003-02-01

    Electrical evoked otoacoustic emissions (EEOAE) are used to investigate in vivo cochlear electromechanical function. Round window electrical stimulation gives rise to a broad frequency EEOAE response, from 100 Hz or below to 40 kHz in guinea pigs. Placing bipolar electrodes very close to the basilar membrane (in the scala vestibuli and scala tympani) gives rise to a much narrower frequency range of EEOAE, limited to around 20 kHz when the electrodes are placed near the 18 kHz best frequency place. Model predictions using a three dimensional fluid model in conjunction with a simple model for outer hair cell (OHC) activity are used to interpret the experimental results. The model is solved using a 2.5D finite-element formulation. Predictions show that the high-frequency limit of the excitation is determined by the spatial extent of the current stimulus (also called the current spread). The global peaks in the EEOAE spectra are interpreted as constructive interference between electrically evoked backward traveling waves and forward traveling waves reflected from the stapes. Steady-state response predictions of the model are presented.

  6. A Jurassic gliding euharamiyidan mammal with an ear of five auditory bones

    NASA Astrophysics Data System (ADS)

    Han, Gang; Mao, Fangyuan; Bi, Shundong; Wang, Yuanqing; Meng, Jin

    2017-11-01

    Gliding is a distinctive locomotion type that has been identified in only three mammal species from the Mesozoic era. Here we describe another Jurassic glider that belongs to the euharamiyidan mammals and shows hair details on its gliding membrane that are highly similar to those of extant gliding mammals. This species possesses a five-boned auditory apparatus consisting of the stapes, incus, malleus, ectotympanic and surangular, representing, to our knowledge, the earliest known definitive mammalian middle ear. The surangular has not been previously identified in any mammalian middle ear, and the morphology of each auditory bone differs from those of known mammals and their kin. We conclude that gliding locomotion was probably common in euharamiyidans, which lends support to idea that there was a major adaptive radiation of mammals in the mid-Jurassic period. The acquisition of the auditory bones in euharamiyidans was related to the formation of the dentary-squamosal jaw joint, which allows a posterior chewing movement, and must have evolved independently from the middle ear structures of monotremes and therian mammals.

  7. Comparison of Fluoroplastic Causse Loop Piston and Titanium Soft-Clip in Stapedotomy

    PubMed Central

    Faramarzi, Mohammad; Gilanifar, Nafiseh; Roosta, Sareh

    2017-01-01

    Introduction: Different types of prosthesis are available for stapes replacement. Because there has been no published report on the efficacy of the titanium soft-clip vs the fluoroplastic Causse loop Teflon piston, we compared short-term hearing results of both types of prosthesis in patients who underwent stapedotomy due to otosclerosis. Materials and Methods: A total of 57 ears were included in the soft-clip group and 63 ears were included in the Teflon-piston group. Pre-operative and post-operative air conduction, bone conduction, air-bone gaps, speech discrimination score, and speech reception thresholds were analyzed. Results: Post-operative speech reception threshold gains did not differ significantly between the two groups (P=0.919). However, better post-operative air-bone gap improvement at low frequencies was observed in the Teflon-piston group over the short-term follow-up (at frequencies of 0.25 and 0.50 kHz; P=0.007 and P=0.001, respectively). Conclusion: Similar post-operative hearing results were observed in the two groups in the short-term. PMID:28229059

  8. Application of the Vibrant Soundbridge middle-ear implant for aural atresia in patients with Treacher Collins syndrome.

    PubMed

    Lesinskas, E; Stankeviciute, V; Petrulionis, M

    2012-12-01

    To present results for the auditory rehabilitation of patients with Treacher Collins syndrome with bilateral osseous atresia, using middle-ear implantation with a Vibrant Soundbridge. Three patients underwent vibroplasty for aural atresia with moderate to severe conductive hearing loss. The pre-operative Jahrsdoerfer radiological score was 4 for all patients. Patients underwent active middle-ear implantation of a Vibrant Soundbridge implant (coupling the floating mass transducer to the rudimentary stapes or footplate distally, and positioning it adjacent to the round window membrane proximally), with audiological analysis as follow up. After implant activation, the mean air conduction threshold ± standard deviation decreased to 22.8 ± 5.5 dB HL, representing a mean functional gain of 44.5 dB. The mean word recognition score (for bisyllabic words at 65 dB SPL) increased from 0 to 97 per cent. Vibrant Soundbridge implantation is an effective hearing rehabilitation procedure in patients with Treacher Collins syndrome with bilateral osseous atresia. This is a versatile implant which can achieve coupling even in cases of severe middle-ear malformation.

  9. Immunolocalization of aquaporin CHIP in the guinea pig inner ear.

    PubMed

    Stanković, K M; Adams, J C; Brown, D

    1995-12-01

    Aquaporin CHIP (AQP-CHIP) is a water channel protein previously identified in red blood cells and water transporting epithelia. The inner ear is an organ of hearing and balance whose normal function depends critically on maintenance of fluid homeostasis. In this study, AQP-CHIP, or a close homologue, was found in specific cells of the inner ear, as assessed by immunocytochemistry with the use of affinity-purified polyclonal antibodies against AQP-CHIP.AQP-CHIP was predominantly found in fibrocytes in close association with bone, including most of the cells lining the bony labyrinth and in fibrocytes lining the endolymphatic duct and sac. AQP-CHIP-positive cells not directly apposing bone include cells under the basilar membrane, some type III fibrocytes of the spiral ligament, fibrocytes of the spiral limbus, and the trabecular perilymphatic tissue extending from the membranous to the bony labyrinth. AQP-CHIP was also found in the periosteum of the middle ear and cranial bones, as well as in chondrocytes of the oval window and stapes. The distribution of AQP-CHIP in the inner ear suggests that AQP-CHIP may have special significance for maintenance of bone and the basilar membrane, and for function of the spiral ligament.

  10. Inner hair cell stereocilia movements captured in-situ by a high-speed camera with subpixel image processing

    NASA Astrophysics Data System (ADS)

    Wang, Yanli; Puria, Sunil; Steele, Charles R.; Ricci, Anthony J.

    2018-05-01

    Mechanical stimulation of the stereocilia hair bundles of the inner and outer hair cells (IHCs and OHCs, respectively) drives IHC synaptic release and OHC electromotility. The modes of hair-bundle motion can have a dramatic influence on the electrophysiological responses of the hair cells. The in vivo modes of motion are, however, unknown for both IHC and OHC bundles. In this work, we are developing technology to investigate the in situ hair-bundle motion in excised mouse cochleae, for which the hair bundles of the OHCs are embedded in the tectorial membrane but those of the IHCs are not. Motion is generated by pushing onto the stapes at 1 kHz with a glass probe coupled to a piezo stack, and recorded using a high-speed camera at 10,000 frames per second. The motions of individual IHC stereocilia and the cell boundary are analyzed using 2D and 1D Gaussian fitting algorithms, respectively. Preliminary results show that the IHC bundle moves mainly in the radial direction and exhibits a small degree of splay, and that the stereocilia in the second row move less than those in the first row, even in the same focal plane.

  11. [Reliable fixation of cochlear implant electrode mountings in children and adults--initial experiences with a new titanium clip].

    PubMed

    Müller, J; Schön, F; Helms, J

    1998-04-01

    There is a reported 1% incidence of delayed migration of extrusions of the electrode arrays out of the cochlea. A titanium clip to fix the electrode array of the MED EL Combi 40 Cochlear Implant System is described. The clip is designed and shaped in a double U configuration. The clip material allows easy adaption to the individual anatomical situation. The clip is fixed to a bony bridge at the incus bar and fixes the electrode in a plane parallel to the chorda facial angle. It is closed around the electrode similarly to a stapes piston around the incus. Additional tests which examined the possible risk of damaging the electrode carrier and clinical findings are described. The clip was used in 23 cases with a follow-up period up to 1 year. No signs for dislocation of the electrode were found. In one revision case the clip was covered with a thin mucosal layer. The electrode array showed no signs of damage. Intraoperative findings confirmed the experimental tests on the electrode fixation. The titanium clip facilitates safe and quick fixation of the electrode array and prevents dislocation. its flexibility and shape minimizes the risk of damage.

  12. The influence of the mechanical behaviour of the middle ear ligaments: a finite element analysis.

    PubMed

    Gentil, F; Parente, M; Martins, P; Garbe, C; Jorge, R N; Ferreira, A; Tavares, João Manuel R S

    2011-01-01

    The interest in computer modelling of biomechanical systems, mainly by using the finite element method (FEM), has been increasing, in particular for analysis of the mechanical behaviour of the human ear. In this work, a finite element model of the middle ear was developed to study the dynamic structural response to harmonic vibrations for distinct sound pressure levels applied on the eardrum. The model includes different ligaments and muscle tendons with elastic and hyperelastic behaviour for these supportive structures. Additionally, the nonlinear behaviour of the ligaments and muscle tendons was investigated, as they are the connection between ossicles by contact formulation. Harmonic responses of the umbo and stapes footplate displacements, between 100 Hz and 10 kHz, were obtained and compared with previously published work. The stress state of ligaments (superior, lateral, and anterior of malleus and superior and posterior of incus) was analysed, with the focus on balance of the supportive structures of the middle ear, as ligaments make the link between the ossicular chain and the walls of the tympanic cavity. The results obtained in this work highlight the importance of using hyperelastic models to simulate the mechanical behaviour for the ligaments and tendons.

  13. Cranial morphology of Sinovenator changii (Theropoda: Troodontidae) on the new material from the Yixian Formation of western Liaoning, China.

    PubMed

    Yin, Ya-Lei; Pei, Rui; Zhou, Chang-Fu

    2018-01-01

    A new three-dimensionally preserved troodontid specimen consisting of most of the skull, partial mandibles and six articulated cervical vertebrae (PMOL-AD00102) from the Early Cretaceous Yixian Formation of Beipiao, western Liaoning, China is identified as Sinovenator changii on the basis of a surangular with a "T"-shaped cross-section. High-resolution computed tomographic data for the skull of this new specimen facilitated a detailed description of the cranial anatomy of S. changii . New diagnostic features of S. changii include a well-developed medial shelf on the jugal, a slender bar in the parasphenoid recess, a lateral groove on the pterygoid flange of the ectopterygoid, and the lateral surface of the anterior cervical vertebrae bearing two pneumatic foramina. Our new observation confirms that the braincase of Sinovenator is not as primitive as previously suggested, although it still shows an intermediate state between derived troodontids and non-troodontid paravians in having an initial stage of the subotic recess and the otosphenoidal crest. Additionally, this new specimen reveals some novel and valuable anatomical information of troodontids regarding the quadrate-quadratojugal articulation, the stapes, the epipterygoid and the atlantal ribs.

  14. Extratympanic observation of middle ear structure using a refractive index matching material (glycerol) and an infrared camera.

    PubMed

    Kong, Soo-Keun; Chon, Kyong-Myong; Goh, Eui-Kyung; Lee, Il-Woo; Wang, Soo-Geun

    2014-05-01

    High-resolution computed tomography has been used mainly in the diagnosis of middle ear disease, such as high-jugular bulb, congenital cholesteatoma, and ossicular disruption. However, certain diagnoses are confirmed through exploratory tympanotomy. There are few noninvasive methods available to observe the middle ear. The purpose of this study was to investigate the effect of glycerol as a refractive index matching material and an infrared (IR) camera system for extratympanic observation. 30% glycerol was used as a refractive index matching material in five fresh cadavers. Each material was divided into four subgroups; GN (glycerol no) group, GO (glycerol out) group, GI (glycerol in) group, and GB (glycerol both) group. A printed letter and middle ear structures on the inside tympanic membrane were observed using a visible and IR ray camera system. In the GB group, there were marked a transilluminated letter or an ossicle on the inside tympanic membrane. In particular, a footplate of stapes was even transilluminated using the IR camera system in the GB group. This method can be useful in the diagnosis of diseases of the middle ear if it is clinically applied through further studies.

  15. Extratympanic observation of middle ear structure using a refractive index matching material (glycerol) and an infrared camera

    NASA Astrophysics Data System (ADS)

    Kong, Soo-Keun; Chon, Kyong-Myong; Goh, Eui-Kyung; Lee, Il-Woo; Wang, Soo-Geun

    2014-05-01

    High-resolution computed tomography has been used mainly in the diagnosis of middle ear disease, such as high-jugular bulb, congenital cholesteatoma, and ossicular disruption. However, certain diagnoses are confirmed through exploratory tympanotomy. There are few noninvasive methods available to observe the middle ear. The purpose of this study was to investigate the effect of glycerol as a refractive index matching material and an infrared (IR) camera system for extratympanic observation. 30% glycerol was used as a refractive index matching material in five fresh cadavers. Each material was divided into four subgroups; GN (glycerol no) group, GO (glycerol out) group, GI (glycerol in) group, and GB (glycerol both) group. A printed letter and middle ear structures on the inside tympanic membrane were observed using a visible and IR ray camera system. In the GB group, there were marked a transilluminated letter or an ossicle on the inside tympanic membrane. In particular, a footplate of stapes was even transilluminated using the IR camera system in the GB group. This method can be useful in the diagnosis of diseases of the middle ear if it is clinically applied through further studies.

  16. Interpreting electrically evoked emissions using a finite-element model of the cochlea

    NASA Astrophysics Data System (ADS)

    Deo, Niranjan V.; Grosh, Karl; Parthasarathi, Anand

    2003-10-01

    Electrically evoked otoacoustic emissions (EEOAEs) are used to investigate in vivo cochlear electromechanical function. Electrical stimulation through bipolar electrodes placed very close to the basilar membrane (in the scala vestibuli and scala tympani) gives rise to a narrow frequency range of EEOAEs, limited to around 20 kHz when the electrodes are placed near the 18-kHz best frequency place. Model predictions using a three-dimensional inviscid fluid model in conjunction with a middle ear model [S. Puria and J. B. Allen, J. Acoust. Soc. Am. 104, 3463-3481 (1998)] and a simple model for outer hair cell activity [S. Neely and D. Kim, J. Acoust. Soc. Am. 94, 137-146 (1993)] are used to interpret the experimental results. To estimate effect of viscosity, model results are compared with those obtained for a viscous fluid. The models are solved using a 2.5-D finite-element formulation. Predictions show that the high frequency limit of the excitation is determined by the spatial extent of the current stimulus. The global peaks in the EEOAE spectra are interpreted as constructive interference between electrically evoked backward traveling waves and forward traveling waves reflected from the stapes. Steady state response predictions of the model are presented.

  17. Signal flow inside the tunnel of Corti

    NASA Astrophysics Data System (ADS)

    de Boer, Egbert; Chen, Fangyi; Zha, Dingjun; Grosh, Karl; Nankali, Amir; Nuttall, Alfred L.

    2018-05-01

    All With the advent of Optical Coherence Tomography (OCT), a variation of the standard laser-interferometer technique, vibrations of various points inside the cochlea can be measured separately and concurrently. In this work we measured vibrations of the basilar membrane (BM) and the Reticular Lamina (RL) in the cochlea of the guinea pig. Stimulus tones had frequencies in the range from 10 to 25 kHz, they were generated and measured with a spacing of 250 Hz. By smoothing and interpolation the spacing was reduced to 50 Hz. We confirmed earlier findings in that in viable animals the responses at the RL are generally larger than those of the BM, and have smaller phase delays. Moreover, these differences are little dependent of the level of stimulation. Our main hypothesis is: stimulation of the stapes primarily excites the structures in the upper (RL) part of the Organ of Corti (OoC) channel. Subsequently, movements of the RL cause movements of the fluid in the OoC channel, which in turn moves the BM. Computation of the sound field generated by the RL yielded results that agree very well with the data. These results thus confirm the hypothesis.

  18. Choristoma of the middle ear: a component of a new syndrome?

    PubMed

    Buckmiller, L M; Brodie, H A; Doyle, K J; Nemzek, W

    2001-05-01

    Salivary choristoma of the middle ear is a rare entity. The authors report the 26th known case, which is unique in several respects: the patient had abnormalities of the first and second branchial arches, as well as the otic capsule and facial nerve in ways not yet reported. Our patient presented with bilateral preauricular pits, conchal bands, an ipsilateral facial palsy, and bilateral Mondini-type deformities. A review of the literature revealed salivary choristomas of the middle ear to be frequently associated with branchial arch abnormalities, most commonly the second, as well as abnormalities of the facial nerve. All 25 cases were reviewed and the results reported with respect to clinical presentation, associated abnormalities, operative findings, and hearing results. It has been proposed that choristoma of the middle ear may represent a component of a syndrome along with unilateral hearing loss, abnormalities of the incus and/or stapes, and anomalies of the facial nerve. Eighty-six percent of the reported patients with choristoma have three or four of the four criteria listed to designate middle ear salivary choristoma as part of a syndrome. In the remaining four patients, all of the structures were not assessed.

  19. Into the dark: patterns of middle ear adaptations in subterranean eulipotyphlan mammals

    NASA Astrophysics Data System (ADS)

    Koyabu, Daisuke; Hosojima, Misato; Endo, Hideki

    2017-09-01

    Evolution of the middle ear ossicles was a key innovation for mammals, enhancing the transmission of airborne sound. Radiation into various habitats from a terrestrial environment resulted in diversification of the auditory mechanisms among mammals. However, due to the paucity of phylogenetically controlled investigations, how middle ear traits have diversified with functional specialization remains unclear. In order to identify the respective patterns for various lifestyles and to gain insights into fossil forms, we employed a high-resolution tomography technique and compared the middle ear morphology of eulipotyphlan species (moles, shrews and hedgehogs), a group that has radiated into various environments, such as terrestrial, aquatic and subterranean habitats. Three-dimensional geometric morphometric analysis was conducted within a phylogenetically controlled framework. Quantitative shapes were found to strongly reflect the degree of subterranean lifestyle and weakly involve phylogeny. Our analyses demonstrate that subterranean adaptation should include a relatively shorter anterior process of the malleus, an enlarged incus, an enlarged stapes footplate and a reduction of the orbicular apophysis. These traits arguably allow improving low-frequency sound transmission at low frequencies and inhibiting the low-frequency noise which disturbs the subterranean animals in hearing airborne sounds.

  20. Response of the human tympanic membrane to transient acoustic and mechanical stimuli: Preliminary results.

    PubMed

    Razavi, Payam; Ravicz, Michael E; Dobrev, Ivo; Cheng, Jeffrey Tao; Furlong, Cosme; Rosowski, John J

    2016-10-01

    The response of the tympanic membrane (TM) to transient environmental sounds and the contributions of different parts of the TM to middle-ear sound transmission were investigated by measuring the TM response to global transients (acoustic clicks) and to local transients (mechanical impulses) applied to the umbo and various locations on the TM. A lightly-fixed human temporal bone was prepared by removing the ear canal, inner ear, and stapes, leaving the incus, malleus, and TM intact. Motion of nearly the entire TM was measured by a digital holography system with a high speed camera at a rate of 42 000 frames per second, giving a temporal resolution of <24 μs for the duration of the TM response. The entire TM responded nearly instantaneously to acoustic transient stimuli, though the peak displacement and decay time constant varied with location. With local mechanical transients, the TM responded first locally at the site of stimulation, and the response spread approximately symmetrically and circumferentially around the umbo and manubrium. Acoustic and mechanical transients provide distinct and complementary stimuli for the study of TM response. Spatial variations in decay and rate of spread of response imply local variations in TM stiffness, mass, and damping. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Impaired Vibration of Auditory Ossicles in Osteopetrotic Mice

    PubMed Central

    Kanzaki, Sho; Takada, Yasunari; Niida, Shumpei; Takeda, Yoshihiro; Udagawa, Nobuyuki; Ogawa, Kaoru; Nango, Nobuhito; Momose, Atsushi; Matsuo, Koichi

    2011-01-01

    In the middle ear, a chain of three tiny bones (ie, malleus, incus, and stapes) vibrates to transmit sound from the tympanic membrane to the inner ear. Little is known about whether and how bone-resorbing osteoclasts play a role in the vibration of auditory ossicles. We analyzed hearing function and morphological features of auditory ossicles in osteopetrotic mice, which lack osteoclasts because of the deficiency of either cytokine RANKL or transcription factor c-Fos. The auditory brainstem response showed that mice of both genotypes experienced hearing loss, and laser Doppler vibrometry revealed that the malleus behind the tympanic membrane failed to vibrate. Histological analysis and X-ray tomographic microscopy using synchrotron radiation showed that auditory ossicles in osteopetrotic mice were thicker and more cartilaginous than those in control mice. Most interestingly, the malleal processus brevis touched the medial wall of the tympanic cavity in osteopetrotic mice, which was also the case for c-Src kinase–deficient mice (with normal numbers of nonresorbing osteoclasts). Osteopetrotic mice showed a smaller volume of the tympanic cavity but had larger auditory ossicles compared with controls. These data suggest that osteoclastic bone resorption is required for thinning of auditory ossicles and enlargement of the tympanic cavity so that auditory ossicles vibrate freely. PMID:21356377

  2. Middle-ear velocity transfer function, cochlear input immittance, and middle-ear efficiency in chinchilla.

    PubMed

    Ravicz, Michael E; Rosowski, John J

    2013-10-01

    The transfer function H(V) between stapes velocity V(S) and sound pressure near the tympanic membrane P(TM) is a descriptor of sound transmission through the middle ear (ME). The ME power transmission efficiency (MEE), the ratio of sound power entering the cochlea to power entering the middle ear, was computed from H(V) measured in seven chinchilla ears and previously reported measurements of ME input admittance Y(TM) and ME pressure gain G(MEP) [Ravicz and Rosowski, J. Acoust. Soc. Am. 132, 2437-2454 (2012); J. Acoust. Soc. Am. 133, 2208-2223 (2013)] in the same ears. The ME was open, and a pressure sensor was inserted into the cochlear vestibule for most measurements. The cochlear input admittance Y(C) computed from H(V) and G(MEP) is controlled by a combination of mass and resistance and is consistent with a minimum-phase system up to 27 kHz. The real part Re{Y(C)}, which relates cochlear sound power to inner-ear sound pressure, decreased gradually with frequency up to 25 kHz and more rapidly above that. MEE was about 0.5 between 0.1 and 8 kHz, higher than previous estimates in this species, and decreased sharply at higher frequencies.

  3. Middle-ear velocity transfer function, cochlear input immittance, and middle-ear efficiency in chinchilla

    PubMed Central

    Ravicz, Michael E.; Rosowski, John J.

    2013-01-01

    The transfer function HV between stapes velocity VS and sound pressure near the tympanic membrane PTM is a descriptor of sound transmission through the middle ear (ME). The ME power transmission efficiency (MEE), the ratio of sound power entering the cochlea to power entering the middle ear, was computed from HV measured in seven chinchilla ears and previously reported measurements of ME input admittance YTM and ME pressure gain GMEP [Ravicz and Rosowski, J. Acoust. Soc. Am. 132, 2437–2454 (2012); J. Acoust. Soc. Am. 133, 2208–2223 (2013)] in the same ears. The ME was open, and a pressure sensor was inserted into the cochlear vestibule for most measurements. The cochlear input admittance YC computed from HV and GMEP is controlled by a combination of mass and resistance and is consistent with a minimum-phase system up to 27 kHz. The real part Re{YC}, which relates cochlear sound power to inner-ear sound pressure, decreased gradually with frequency up to 25 kHz and more rapidly above that. MEE was about 0.5 between 0.1 and 8 kHz, higher than previous estimates in this species, and decreased sharply at higher frequencies. PMID:24116422

  4. Sound pressure gain produced by the human middle ear.

    PubMed

    Kurokawa, H; Goode, R L

    1995-10-01

    The acoustic function of the middle ear is to match sound passing from the low impedance of air to the high impedance of cochlear fluid. Little information is available on the actual middle ear pressure gain in human beings. This article describes experiments on middle ear pressure gain in six fresh human temporal bones. Stapes footplate displacement and phase were measured with a laser Doppler vibrometer before and after removal of the tympanic membrane, malleus, and incus. Acoustic insulation of the round window with clay was performed. Umbo displacement was also measured before tympanic membrane removal to assess baseline tympanic membrane function. The middle ear has its major gain in the lower frequencies, with a peak near 0.9 kHz. The mean gain was 23.0 dB below 1.0 kHz, the resonant frequency of the middle ear; the mean peak gain was 26.6 dB. Above 1.0 kHz, the second pressure gain decreased at a rate of -8.6 dB/octave, with a mean gain of 6.5 dB at 4.0 kHz. Only a small amount of gain was present above 7.0 kHz. Significant individual differences in pressure gain were found between ears that appeared related to variations in tympanic membrane function and not to variations in cochlear impedance.

  5. Response of the human tympanic membrane to transient acoustic and mechanical stimuli: Preliminary results

    PubMed Central

    Razavi, Payam; Ravicz, Michael E.; Dobrev, Ivo; Cheng, Jeffrey Tao; Furlong, Cosme; Rosowski, John J.

    2016-01-01

    The response of the tympanic membrane (TM) to transient environmental sounds and the contributions of different parts of the TM to middle-ear sound transmission were investigated by measuring the TM response to global transients (acoustic clicks) and to local transients (mechanical impulses) applied to the umbo and various locations on the TM. A lightly-fixed human temporal bone was prepared by removing the ear canal, inner ear, and stapes, leaving the incus, malleus, and TM intact. Motion of nearly the entire TM was measured by a digital holography system with a high speed camera at a rate of 42 000 frames per second, giving a temporal resolution of <24 μs for the duration of the TM response. The entire TM responded nearly instantaneously to acoustic transient stimuli, though the peak displacement and decay time constant varied with location. With local mechanical transients, the TM responded first locally at the site of stimulation, and the response spread approximately symmetrically and circumferentially around the umbo and manubrium. Acoustic and mechanical transients provide distinct and complementary stimuli for the study of TM response. Spatial variations in decay and rate of spread of response imply local variations in TM stiffness, mass, and damping. PMID:26880098

  6. Creation of a 3D printed temporal bone model from clinical CT data.

    PubMed

    Cohen, Joss; Reyes, Samuel A

    2015-01-01

    Generate and describe the process of creating a 3D printed, rapid prototype temporal bone model from clinical quality CT images. We describe a technique to create an accurate, alterable, and reproducible rapid prototype temporal bone model using freely available software to segment clinical CT data and generate three different 3D models composed of ABS plastic. Each model was evaluated based on the appearance and size of anatomical structures and response to surgical drilling. Mastoid air cells had retained scaffolding material in the initial versions. This required modifying the model to allow drainage of the scaffolding material. External auditory canal dimensions were similar to those measured from the clinical data. Malleus, incus, oval window, round window, promontory, horizontal semicircular canal, and mastoid segment of the facial nerve canal were identified in all models. The stapes was only partially formed in two models and absent in the third. Qualitative feel of the ABS plastic was softer than bone. The pate produced by drilling was similar to bone dust when appropriate irrigation was used. We present a rapid prototype temporal bone model made based on clinical CT data using 3D printing technology. The model can be made quickly and inexpensively enough to have potential applications for educational training. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. A high-resolution imaging technique using a whole-body, research photon counting detector CT system

    NASA Astrophysics Data System (ADS)

    Leng, S.; Yu, Z.; Halaweish, A.; Kappler, S.; Hahn, K.; Henning, A.; Li, Z.; Lane, J.; Levin, D. L.; Jorgensen, S.; Ritman, E.; McCollough, C.

    2016-03-01

    A high-resolution (HR) data collection mode has been introduced to a whole-body, research photon-counting-detector CT system installed in our laboratory. In this mode, 64 rows of 0.45 mm x 0.45 mm detector pixels were used, which corresponded to a pixel size of 0.25 mm x 0.25 mm at the iso-center. Spatial resolution of this HR mode was quantified by measuring the MTF from a scan of a 50 micron wire phantom. An anthropomorphic lung phantom, cadaveric swine lung, temporal bone and heart specimens were scanned using the HR mode, and image quality was subjectively assessed by two experienced radiologists. High spatial resolution of the HR mode was evidenced by the MTF measurement, with 15 lp/cm and 20 lp/cm at 10% and 2% modulation. Images from anthropomorphic phantom and cadaveric specimens showed clear delineation of small structures, such as lung vessels, lung nodules, temporal bone structures, and coronary arteries. Temporal bone images showed critical anatomy (i.e. stapes superstructure) that was clearly visible in the PCD system. These results demonstrated the potential application of this imaging mode in lung, temporal bone, and vascular imaging. Other clinical applications that require high spatial resolution, such as musculoskeletal imaging, may also benefit from this high resolution mode.

  8. Boundary-integral modeling of cochlear hydrodynamics

    NASA Astrophysics Data System (ADS)

    Pozrikidis, C.

    2008-04-01

    A two-dimensional model that captures the essential features of the vibration of the basilar membrane of the cochlea is proposed. The flow due to the vibration of the stapes footplate and round window is modeled by a point source and a point sink, and the cochlear pressure is computed simultaneously with the oscillations of the basilar membrane. The mathematical formulation relies on the boundary-integral representation of the potential flow established far from the basilar membrane and cochlea side walls, neglecting the thin Stokes boundary layer lining these surfaces. The boundary-integral approach furnishes integral equations for the membrane vibration amplitude and pressure distribution on the upper or lower side of the membrane. Several approaches are discussed, and numerical solutions in the frequency domain are presented for a rectangular cochlea model using different membrane response functions. The numerical results reproduce and extend the theoretical predictions of previous authors and delineate the effect of physical and geometrical parameters. It is found that the membrane vibration depends weakly on the position of the membrane between the upper and lower wall of the cochlear channel and on the precise location of the oval and round windows. Solutions of the initial-value problem with a single-period sinusoidal impulse reveal the formation of a traveling wave packet that eventually disappears at the helicotrema.

  9. Thyroid Hormone Receptors Control Developmental Maturation of the Middle Ear and the Size of the Ossicular Bones

    PubMed Central

    Cordas, Emily A.; Ng, Lily; Hernandez, Arturo; Kaneshige, Masahiro; Cheng, Sheue-Yann

    2012-01-01

    Thyroid hormone is critical for auditory development and has well-known actions in the inner ear. However, less is known of thyroid hormone functions in the middle ear, which contains the ossicles (malleus, incus, stapes) that relay mechanical sound vibrations from the outer ear to the inner ear. During the later stages of middle ear development, prior to the onset of hearing, middle ear cavitation occurs, involving clearance of mesenchyme from the middle ear cavity while the immature cartilaginous ossicles attain appropriate size and ossify. Using in situ hybridization, we detected expression of Thra and Thrb genes encoding thyroid hormone receptors α1 and β (TRα1 and TRβ, respectively) in the immature ossicles, surrounding mesenchyme and tympanic membrane in the mouse. Thra+/PV mice that express a dominant-negative TRα1 protein exhibited deafness with elevated auditory thresholds and a range of middle ear abnormalities including chronic persistence of mesenchyme in the middle ear into adulthood, markedly enlarged ossicles, and delayed ossification of the ossicles. Congenitally hypothyroid Tshr−/− mice and TR-deficient Thra1−/−;Thrb−/− mice displayed similar abnormalities. These findings demonstrate that middle ear maturation is TR dependent and suggest that the middle ear is a sensitive target for thyroid hormone in development. PMID:22253431

  10. Measurement of in vivo basal-turn vibrations of the organ of Corti using phase-sensitive Fourier domain optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Ramamoorthy, Sripriya; Zhang, Yuan; Petrie, Tracy; Chen, Fangyi; Subhash, Hrebesh M.; Choudhury, Niloy; Wang, Ruikang; Jacques, Steven L.; Nuttall, Alfred L.

    2013-03-01

    A major reason we can perceive faint sounds and communicate in noisy environments is that the outer hair cells of the organ of Corti enhance the sound-evoked motions inside the cochlea. To understand how the organ of Corti works, we have built and tested the phase-sensitive Fourier domain optical coherence tomography (PSFDOCT) system. This system has key advantages over our previous time domain OCT system [1]. The PSFDOCT system has better signal to noise and simultaneously acquires vibration data from all points along the optical-axis [2]. Feasibility of this system to measure in vitro cochlear vibrations in the apex was demonstrated earlier [3]. In this study, we measure the in vivo vibrations of the organ of Corti via round window in live anaesthetized guinea pigs using PSFDOCT. This region of the guinea pig cochlea responds to very high frequencies (10 - 40 kHz). The current vibration noise floor for native organ of Corti tissue is 0.03 nm in this frequency range. Sound-induced vibrations of the stapes, which delivers input to the cochlea, are also measured. The measured vibrations of the organ of Corti demonstrate non-linear compression and active amplification characteristic of sensitive mammalian cochlea.

  11. Basilar-membrane interference patterns from multiple internal reflection of cochlear traveling waves.

    PubMed

    Shera, Christopher A; Cooper, Nigel P

    2013-04-01

    At low stimulus levels, basilar-membrane (BM) mechanical transfer functions in sensitive cochleae manifest a quasiperiodic rippling pattern in both amplitude and phase. Analysis of the responses of active cochlear models suggests that the rippling is a mechanical interference pattern created by multiple internal reflection within the cochlea. In models, the interference arises when reverse-traveling waves responsible for stimulus-frequency otoacoustic emissions (SFOAEs) reflect off the stapes on their way to the ear canal, launching a secondary forward-traveling wave that combines with the primary wave produced by the stimulus. Frequency-dependent phase differences between the two waves then create the rippling pattern measurable on the BM. Measurements of BM ripples and SFOAEs in individual chinchilla ears demonstrate that the ripples are strongly correlated with the acoustic interference pattern measured in ear-canal pressure, consistent with a common origin involving the generation of SFOAEs. In BM responses to clicks, the ripples appear as temporal fine structure in the response envelope (multiple lobes, waxing and waning). Analysis of the ripple spacing and response phase gradients provides a test for the role of fast- and slow-wave modes of reverse energy propagation within the cochlea. The data indicate that SFOAE delays are consistent with reverse slow-wave propagation but much too long to be explained by fast waves.

  12. Anatomic Malformations of the Middle and Inner Ear in 22q11.2 Deletion Syndrome: Case Series and Literature Review.

    PubMed

    Verheij, E; Elden, L; Crowley, T B; Pameijer, F A; Zackai, E H; McDonald-McGinn, D M; Thomeer, H G X M

    2018-05-01

    The 22q11.2 deletion syndrome is characterized by a heterogenic phenotype, including hearing loss. The underlying cause of hearing loss, especially sensorineural hearing loss, is not yet clear. Therefore, our objective was to describe anatomic malformations in the middle and inner ear in patients with 22q11.2 deletion syndrome. A retrospective case series was conducted in 2 tertiary referral centers. All patients with 22q11.2 deletion syndrome who had undergone CT or MR imaging of the temporal bones were included. Radiologic images were evaluated on predetermined parameters, including abnormalities of the ossicular chain, cochlea, semicircular canals, and vestibule. There were 26 patients (52 ears) with a CT or MR imaging scan available. A dense stapes superstructure was found in 18 ears (36%), an incomplete partition type II was suspected in 12 cochleas (23%), the lateral semicircular canal was malformed with a small bony island in 17 ears (33%), and the lateral semicircular canal and vestibule were fused to a single cavity in 15 ears (29%). Middle and inner ear abnormalities were frequently encountered in our cohort, including malformations of the lateral semicircular canal. © 2018 by American Journal of Neuroradiology.

  13. Cranial Morphology of the Carboniferous-Permian Tetrapod Brachydectes newberryi (Lepospondyli, Lysorophia): New Data from µCT

    PubMed Central

    Pardo, Jason D.; Anderson, Jason S.

    2016-01-01

    Lysorophians are a group of early tetrapods with extremely elongate trunks, reduced limbs, and highly reduced skulls. Since the first discovery of this group, general similarities in outward appearance between lysorophians and some modern lissamphibian orders (specifically Urodela and Gymnophiona) have been recognized, and sometimes been the basis for hypotheses of lissamphibian origins. We studied the morphology of the skull, with particular emphasis on the neurocranium, of a partial growth series of the lysorophian Brachydectes newberryi using x-ray micro-computed tomography (μCT). Our study reveals similarities between the braincase of Brachydectes and brachystelechid recumbirostrans, corroborating prior work suggesting a close relationship between these taxa. We also describe the morphology of the epipterygoid, stapes, and quadrate in this taxon for the first time. Contra the proposals of some workers, we find no evidence of expected lissamphibian synapomorphies in the skull morphology in Brachydectes newberryi, and instead recognize a number of derived amniote characteristics within the braincase and suspensorium. Morphology previously considered indicative of taxonomic diversity within Lysorophia may reflect ontogenetic rather than taxonomic variation. The highly divergent morphology of lysorophians represents a refinement of morphological and functional trends within recumbirostrans, and is analogous to morphology observed in many modern fossorial reptiles. PMID:27563722

  14. A 3D-printed functioning anatomical human middle ear model.

    PubMed

    Kuru, Ismail; Maier, Hannes; Müller, Mathias; Lenarz, Thomas; Lueth, Tim C

    2016-10-01

    The middle ear is a sophisticated and complex structure with a variety of functions, yet a delicate organ prone to injuries due to various reasons. Both, understanding and reconstructing its functions has always been an important topic for researchers from medical and technical background. Currently, human temporal bones are generally used as model for tests, experiments and validation of the numerical results. However, fresh human preparations are not always easily accessible and their mechanical properties vary with time and between individuals. Therefore we have built an anatomically based and functional middle ear model to serve as a reproducible test environment. Our middle ear model was manufactured with the aid of 3D-printing technology. We have segmented the essential functional elements from micro computed tomography data (μCT) of a single temporal bone. The ossicles were 3D-printed by selective laser melting (SLM) and the soft tissues were casted with silicone rubber into 3D-printed molds. The ear canal, the tympanic cavity and the inner ear were artificially designed, but their design ensured the anatomically correct position of the tympanic membrane, ossicular ligaments and the oval window. For the determination of their auditory properties we have conducted two kinds of tests: measurement of the stapes footplate response to sound and tympanometry of the model. Our experiments regarding the sound transmission showed that the model has a similar behavior to a human middle ear. The transfer function has a resonance frequency at around 1 kHz, the stapes' response is almost constant for frequencies below the resonance and a roll-off is observed above the resonance. The tympanometry results show that the compliance of the middle ear model is similar to the compliance of a healthy human middle ear. We also present that we were able to manipulate the transmission behavior, so that healthy or pathological scenarios can be created. For this purpose we have built models with different mechanical properties by varying the hardness of the silicone rubber used for different structures, such as tympanic membrane, oval window and ossicle attachments in the range of Shore 10-40 A. This allowed us to set the transmission amplitudes in the plateau region higher, lower or within the tolerances of normal middle ears (Rosowski et al., 2007). Our results showed that it is possible to build an artificial model of the human middle ear by using 3D-printing technology in combination with silicone rubber molding. We were able to reproduce the anatomical shape of the middle ear's essential elements with high accuracy and also assemble them into a functioning middle ear model. The acoustic behavior of the model can be reproduced and manipulated by the choice of material. If the issues such as resonance of the casing and steep roll-off slope in higher frequencies can be solved, this model creates a reproducible environment for experiments and can be useful for the evaluation of prosthetic devices. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Measurement of the Three-Dimensional Vibration Motion of the Ossicular Chain in the Living Gerbil

    NASA Astrophysics Data System (ADS)

    Decraemer, Willem F.; de La Rochefoucauld, Ombeline; Olson, Elizabeth S.

    2011-11-01

    In previous studies 3D motion of the middle-ear ossicles in cat and human temporal bone were explored but models for hearing research has shifted in the last decades to smaller mammals and gerbil in particular has become a hearing model of first choice. In the present study we have measured with an optical interferometer the 3D motion of the malleus and incus in anesthetized gerbil for sound of moderate intensity (90 dB SPL) in a broad frequency range. To access the malleus and incus the pars flaccida was completely removed exposing the neck and head of the malleus and the incus from the malleus-incus joint to the long process of the incus and the plate of the lenticular process. In a previous study an approach through a hole in the bullar wall was used to study the stapes motion so that we now have a complete picture of the middle ear motion. In both approaches vibration measurements were done at 6 to 7 points per ossicle while the angle of observation was varied over approximately 30 degrees to enable calculation of the 3D velocity components. Knowledge of middle ear motion is of great importance in understanding how the middle ear transforms the acoustical input from the ear canal to the cochlea.

  16. The lenticular process of the incus.

    PubMed

    Graboyes, Evan M; Hullar, Timothy E; Chole, Richard A

    2011-12-01

    Seventeenth century anatomists, including Franciscus Sylvius, identified a small bony structure between the distal end of the incus and the stapes that they believed was a separate and thus additional ossicle. The existence of the ossicle at the distal end of the long process of the incus was controversial for the next 200 years. In the 19 th century, anatomists including Johann Friedrich Blumenbach, Samuel Thomas Soemmerring, Henry Jones Shrapnell, Eduard Hagenbach, and Joseph Hyrtl provided numerous arguments to demonstrate why the so-called additional ossicle was actually attached to the incus by a thin strut, and thus not a separate bone. The objective of this study was to review the history of the discovery and description of the lenticular process of the incus. Data sources included original published manuscripts and monographs obtained from the historical collections at Washington University in St. Louis and photographs of original materials from cooperating libraries. A detailed study of the published evidence revealed that the lenticular process of the incus was originally thought to be a separate, or fourth, ossicle. Later studies revealed that the lenticular "ossicle" was actually attached to the incus by a thin strut. The ovoid end of the incus should be referred to as the "lenticular process" of the incus, attached to the long process by a thin strut or pedicle. The best nomenclature for the bony connection between the lenticular process and the long process of the incus remains uncertain.

  17. Performance of the round window soft coupler for the backward stimulation of the cochlea in a temporal bone model.

    PubMed

    Gostian, Antoniu-Oreste; Schwarz, David; Mandt, Philipp; Anagiotos, Andreas; Ortmann, Magdalene; Pazen, David; Beutner, Dirk; Hüttenbrink, Karl-Bernd

    2016-11-01

    The round window vibroplasty is a feasible option for the treatment of conductive, sensorineural and mixed hearing loss. Although clinical data suggest a satisfying clinical outcome with various coupling methods, the most efficient coupling technique of the floating mass transducer to the round window is still a matter of debate. For this, a soft silicone-made coupler has been developed recently that aims to ease and optimize the stimulation of the round window membrane of this middle ear implant. We performed a temporal bone study evaluating the performance of the soft coupler compared to the coupling with individually shaped cartilage, perichondrium and the titanium round window coupler with loads up to 20 mN at the unaltered and fully exposed round window niche. The stimulation of the cochlea was measured by the volume velocities of the stapes footplate detected by a laser Doppler vibrometer. The coupling method was computed as significant factor with cartilage and perichondrium allowing for the highest volume velocities followed by the soft and titanium coupler. Exposure of the round window niche allowed for higher volume velocities while the applied load did not significantly affect the results. The soft coupler allows for a good contact to the round window membrane and an effective backward stimulation of the cochlea. Clinical data are mandatory to evaluate performance of this novel coupling method in vivo.

  18. Giovanni Filippo Ingrassia: A five-hundred year-long lesson.

    PubMed

    Cappello, Francesco; Gerbino, Aldo; Zummo, Giovanni

    2010-10-01

    Giovanni Filippo Ingrassia was born five centuries ago in Regalbuto, a small town in the center of Sicily. After his medical course in Padua, under the guidance of Vesalius and Fallopius, he gained international fame as a physician and was recruited as a Professor of human anatomy in Naples and later in Palermo. He is remembered as "the new Galen" or "the Sicilian Hippocrates." He contributed to the knowledge of human anatomy through the description of single bones rather than the whole skeleton. In particular, he was the first to describe the "stapes," the "lesser wings of the sphenoid" and various other structures in the head (probably the pharyngotympanic tube) as well as in the reproductive system (corpora cavernosa and seminal vesicles). He was also a pioneer in the study of forensic medicine, hygiene, surgical pathology, and teratology. As Protomedicus of Sicily, he developed the scientific culture in this country. During those years, he faced the spread of malaria and plague with competence and authoritativeness. Indeed, he was one of the first physicians to suppose that certain diseases could be transmitted between individuals, therefore, introducing revolutionary measures of prevention. He is remembered for his intellectual authority and honesty. Five-hundred years after his birth, his teaching is still alive. In this article, we survey the life and contribution of this pioneer of early anatomical study. Copyright © 2010 Wiley-Liss, Inc.

  19. Dynamic properties of human incudostapedial joint-Experimental measurement and finite element modeling.

    PubMed

    Jiang, Shangyuan; Gan, Rong Z

    2018-04-01

    The incudostapedial joint (ISJ) is a synovial joint connecting the incus and stapes in the middle ear. Mechanical properties of the ISJ directly affect sound transmission from the tympanic membrane to the cochlea. However, how ISJ properties change with frequency has not been investigated. In this paper, we report the dynamic properties of the human ISJ measured in eight samples using a dynamic mechanical analyzer (DMA) for frequencies from 1 to 80 Hz at three temperatures of 5, 25 and 37 °C. The frequency-temperature superposition (FTS) principle was used to extrapolate the results to 8 kHz. The complex modulus of ISJ was measured with a mean storage modulus of 1.14 MPa at 1 Hz that increased to 3.01 MPa at 8 kHz, and a loss modulus that increased from 0.07 to 0.47 MPa. A 3-dimensional finite element (FE) model consisting of the articular cartilage, joint capsule and synovial fluid was then constructed to derive mechanical properties of ISJ components by matching the model results to experimental data. Modeling results showed that mechanical properties of the joint capsule and synovial fluid affected the dynamic behavior of the joint. This study contributes to a better understanding of the structure-function relationship of the ISJ for sound transmission. Copyright © 2018. Published by Elsevier Ltd.

  20. The effect of superior canal dehiscence on cochlear potential in response to air-conducted stimuli in chinchilla

    PubMed Central

    Songer, Jocelyn E.; Rosowski, John J.

    2006-01-01

    A superior semicircular canal dehiscence (SCD) is a break or hole in the bony wall of the superior semicircular canal. Patients with SCD syndrome present with a variety of symptoms: some with vestibular symptoms, others with auditory symptoms (including low-frequency conductive hearing loss) and yet others with both. We are interested in whether or not mechanically altering the superior canal by introducing a dehiscence is sufficient to cause the low-frequency conductive hearing loss associated with SCD syndrome. We evaluated the effect of a surgically introduced dehiscence on auditory responses to air-conducted (AC) stimuli in 11 chinchilla ears. Cochlear potential (CP) was recorded at the round-window before and after a dehiscence was introduced. In each ear, a decrease in CP in response to low frequency (<2 kHz) sound stimuli was observed after the introduction of the dehiscence. The dehiscence was then patched with cyanoacrylate glue leading to a reversal of the dehiscence-induced changes in CP. The reversible decrease in auditory sensitivity observed in chinchilla is consistent with the elevated AC thresholds observed in patients with SCD. According to the ‘third-window’ hypothesis the SCD shunts sound-induced stapes velocity away from the cochlea, resulting in decreased auditory sensitivity to AC sounds. The data collected in this study are consistent with predictions of this hypothesis. PMID:16150562

  1. Auditory Brainstem Circuits That Mediate the Middle Ear Muscle Reflex

    PubMed Central

    Mukerji, Sudeep; Windsor, Alanna Marie; Lee, Daniel J.

    2010-01-01

    The middle ear muscle (MEM) reflex is one of two major descending systems to the auditory periphery. There are two middle ear muscles (MEMs): the stapedius and the tensor tympani. In man, the stapedius contracts in response to intense low frequency acoustic stimuli, exerting forces perpendicular to the stapes superstructure, increasing middle ear impedance and attenuating the intensity of sound energy reaching the inner ear (cochlea). The tensor tympani is believed to contract in response to self-generated noise (chewing, swallowing) and nonauditory stimuli. The MEM reflex pathways begin with sound presented to the ear. Transduction of sound occurs in the cochlea, resulting in an action potential that is transmitted along the auditory nerve to the cochlear nucleus in the brainstem (the first relay station for all ascending sound information originating in the ear). Unknown interneurons in the ventral cochlear nucleus project either directly or indirectly to MEM motoneurons located elsewhere in the brainstem. Motoneurons provide efferent innervation to the MEMs. Although the ascending and descending limbs of these reflex pathways have been well characterized, the identity of the reflex interneurons is not known, as are the source of modulatory inputs to these pathways. The aim of this article is to (a) provide an overview of MEM reflex anatomy and physiology, (b) present new data on MEM reflex anatomy and physiology from our laboratory and others, and (c) describe the clinical implications of our research. PMID:20870664

  2. X-Ray Constraints on the Warm-Hot Intergalactic Medium

    NASA Technical Reports Server (NTRS)

    Kuntz, K. D.; Snowden, S. I.; Mushotzky, R. F.; White, Nicholas E. (Technical Monitor)

    2000-01-01

    Three observational constraints can be placed on a warm-hot intergalactic medium (WHIM) using ROSAT Position Sensitive Proportional Counter (PSPC) pointed and survey data, the emission strength, the energy spectrum, and the fluctuation spectrum. The upper limit to the emission strength of the WHIM is 7.5 +/- 1.0 keV/(s*sq cm*sr*keV) in the 3/4 keV band, an unknown portion of which value may be due to our own Galactic halo. The spectral stape of the WHIM emission can be described as thermal emission with logT = 6.42, although the true spectrum is more likely to come from a range of temperatures. The values of emission strength and spectral shape are in reasonable agreement with hydrodynamical cosmological models. The autocorrelation function in the 0.44 keV < E < 1.21 keV band range, w(theta), for the extragalactic soft X-ray background (SXRB) which includes both the WHIM and contributions due to point sources, is approx. < 0.002 for 10 min < 0 < 20 min in the 3/4 keV band. This value is lower than the Croft et al. (2000) cosmological model by a factor of approx. 5, but is still not inconsistent with cosmological models. It is also found that the normalization of the extragalactic power law component of the soft X-ray background spectrum must be 9.5 +/- 0.9 keV/(s*sq cm*sr*keV) to be consistent with the ROSAT All-Sky Survey.

  3. Inner ear contribution to bone conduction hearing in the human.

    PubMed

    Stenfelt, Stefan

    2015-11-01

    Bone conduction (BC) hearing relies on sound vibration transmission in the skull bone. Several clinical findings indicate that in the human, the skull vibration of the inner ear dominates the response for BC sound. Two phenomena transform the vibrations of the skull surrounding the inner ear to an excitation of the basilar membrane, (1) inertia of the inner ear fluid and (2) compression and expansion of the inner ear space. The relative importance of these two contributors were investigated using an impedance lumped element model. By dividing the motion of the inner ear boundary in common and differential motion it was found that the common motion dominated at frequencies below 7 kHz but above this frequency differential motion was greatest. When these motions were used to excite the model it was found that for the normal ear, the fluid inertia response was up to 20 dB greater than the compression response. This changed in the pathological ear where, for example, otosclerosis of the stapes depressed the fluid inertia response and improved the compression response so that inner ear compression dominated BC hearing at frequencies above 400 Hz. The model was also able to predict experimental and clinical findings of BC sensitivity in the literature, for example the so called Carhart notch in otosclerosis, increased BC sensitivity in superior semicircular canal dehiscence, and altered BC sensitivity following a vestibular fenestration and RW atresia. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Investigation of a broadband duct noise control system inspired by the middle ear mechanism

    NASA Astrophysics Data System (ADS)

    Wang, Chunqi; Huang, Lixi

    2012-08-01

    A new duct noise control device is introduced based on the mechanism of human middle ear which functions as a compact, broadband impedance transformer between the air motion in the outer ear and the liquid motion in the inner ear. The system consists of two rigid endplates, simulating the tympanic membrane and the stapes footplate, and they are connected by a single rigid rod, simulating the overall action of the ossicular chain. These three pieces are placed in a side-branch cavity, and the whole device is called an ossicular silencer. A specific configuration is investigated numerically with a two-dimensional finite element model. Results show that broadband noise attenuation can be achieved in the very low frequency regime. Typically, two or more resonance peaks are found and the transmission loss between two neighbouring peaks is maintained at a high level. The cavity length is found to be the most crucial parameter that determines the effective frequency range of the ossicular silencer. The total cavity volume, which is a major controlling factor in most existing noise control devices, becomes less influential. The fluid medium in the enclosed cavity mainly acts like an added mass, while its stiffness effect is negligible. Simplified plane wave analysis is also conducted to reveal the mechanisms of the system resonances. The first resonance is identified as of the mass-spring system with mass contributions from both fluid and the plates, while the second one is of the Herschel-Quincke (HQ) tube resonance.

  5. Laser Doppler Vibrometry measurements of human cadaveric tympanic membrane vibration

    PubMed Central

    2013-01-01

    Objective To determine the feasibility of measuring tympanic membrane (TM) vibrations at multiple locations on the TM to differentiate normal eardrums from those with associated ossicular pathologies. Design Cadaveric human temporal bone study. Setting Basic science laboratory. Methods A mastoidectomy and facial recess approach was performed on four cadaveric temporal bones to obtain access to the ossicles without disrupting the TM. Ossicles were palpated to ensure normal mobility and an intact ossicular chain. Laser Doppler Vibrometry (LDV) measurements were then taken on all four TMs. LDV measurements were repeated on each TM following stapes footplate fixation, incudo-stapedial joint dislocation, and malleus head fixation. Main outcome measures LDV measurements of TM vibration at the umbo, the lateral process of the malleus, and in each of the four quadrants of the TM. Results The best signal-to-noise ratios were found between 2 and 4 kHz, at the umbo, the anterior superior quadrant, the anterior inferior quadrant, and the posterior inferior quadrant. Since our goal was to assess the ossicular chain, we selected the TM locations closest to the ossicular chain (the umbo and lateral process of the malleus) for further analysis. Differences could be seen between normals and the simulated ossicular pathologies, but values were not statistically significant. Conclusions LDV measurements are technically challenging and require optimization to obtain consistent measurements. This study demonstrates the potential of LDV to differentiate ossicular pathologies behind an intact tympanic membrane. Future studies will further characterize the clinical role of this diagnostic modality. PMID:23663748

  6. Morphology and function of Neandertal and modern human ear ossicles

    PubMed Central

    David, Romain; Gunz, Philipp; Schmidt, Tobias; Spoor, Fred; Hublin, Jean-Jacques

    2016-01-01

    The diminutive middle ear ossicles (malleus, incus, stapes) housed in the tympanic cavity of the temporal bone play an important role in audition. The few known ossicles of Neandertals are distinctly different from those of anatomically modern humans (AMHs), despite the close relationship between both human species. Although not mutually exclusive, these differences may affect hearing capacity or could reflect covariation with the surrounding temporal bone. Until now, detailed comparisons were hampered by the small sample of Neandertal ossicles and the unavailability of methods combining analyses of ossicles with surrounding structures. Here, we present an analysis of the largest sample of Neandertal ossicles to date, including many previously unknown specimens, covering a wide geographic and temporal range. Microcomputed tomography scans and 3D geometric morphometrics were used to quantify shape and functional properties of the ossicles and the tympanic cavity and make comparisons with recent and extinct AMHs as well as African apes. We find striking morphological differences between ossicles of AMHs and Neandertals. Ossicles of both Neandertals and AMHs appear derived compared with the inferred ancestral morphology, albeit in different ways. Brain size increase evolved separately in AMHs and Neandertals, leading to differences in the tympanic cavity and, consequently, the shape and spatial configuration of the ossicles. Despite these different evolutionary trajectories, functional properties of the middle ear of AMHs and Neandertals are largely similar. The relevance of these functionally equivalent solutions is likely to conserve a similar auditory sensitivity level inherited from their last common ancestor. PMID:27671643

  7. Was Cheselden's One-Century-Long Otological Writings Concordant With His Time?

    PubMed

    Corrales, C Eduardo; Mudry, Albert

    2015-08-01

    William Cheselden's famous anatomical treatise spanned the entire 18th century period with its 15 editions. The aim of this study is to analyze the otological knowledge described in all these editions, to identify key 18th century otological advancements, and to study their concordance.In the first edition (1713), Cheselden notably mentioned four middle ear ossicles: malleus, incus, fourth ossicle, and stapes; four auditory muscles: "external tympani," "external oblique," tensor tympani, and stapedial; and a small opening in the tympanic membrane. In subsequent editions, minimal changes appeared, except for nomenclature changes and the proposal of an artificial opening of the tympanic membrane. Virtually no changes were performed up to the last edition (1806). All Cheselden's Editions confirm the uncertain presence of a fourth ossicle, the disputable presence of a tympanic membrane opening and the "usual" accepted presence of three muscles to the malleus. Key otologic advancements, not found in any of Cheselden's writings, were catherization of the Eustachian tube, presence of fluid in the inner ear, and the surgical opening of the mastoid.This study demonstrates that Cheselden, and his subsequent editors, were unaware of some important otologic developments that revolutionized the field of otology. Description of key advancements lacking in his treatise includes catherization of the Eustachian tube, the presence of fluid in the inner ear, and the surgical opening of the mastoid. Nevertheless, Cheselden is first in proposing to artificially open the tympanic membrane in humans.

  8. Endoscopic versus transcranial procurement of allograft tympano-ossicular systems: a prospective double-blind randomized controlled audit.

    PubMed

    Caremans, Jeroen; Hamans, Evert; Muylle, Ludo; Van de Heyning, Paul; Van Rompaey, Vincent

    2016-06-01

    Allograft tympano-ossicular systems (ATOS) have proven their use over many decades in tympanoplasty and reconstruction after resection of cholesteatoma. The transcranial bone plug technique has been used in the past 50 years to procure en bloc ATOS (tympanic membrane with malleus, incus and stapes attached). Recently, our group reported the feasibility of the endoscopic procurement technique. The aim of this study was to assess whether clinical outcome is equivalent in ATOS acquired by using the endoscopic procurement technique compared to ATOS acquired by using the transcranial technique. A double-blind randomized controlled audit was performed in a tertiary referral center in patients that underwent allograft tympanoplasty because of chronic otitis media with and without cholesteatoma. Allograft epithelialisation was evaluated at the short-term postoperative visit by microscopic examination. Failures were reported if reperforation was observed. Fifty patients underwent allograft tympanoplasty: 34 received endoscopically procured ATOS and 16 received transcranially procured ATOS. One failed case was observed, in the endoscopic procurement group. We did not observe a statistically significant difference between the two groups in failure rate. This study demonstrates equivalence of the clinical outcome of allograft tympanoplasty using either endoscopic or transcranial procured ATOS and therefore indicates that the endoscopic technique can be considered the new standard procurement technique. Especially because the endoscopic procurement technique has several advantages compared to the former transcranial procurement technique: it avoids risk of prion transmission and it is faster while lacking any noticeable incision.

  9. Elastic fiber-mediated enthesis in the human middle ear

    PubMed Central

    Kawase, Tetsuaki; Shibata, Shunichi; Katori, Yukio; Ohtsuka, Aiji; Murakami, Gen; Fujimiya, Mineko

    2012-01-01

    Adaptation to constant vibration (acoustic oscillation) is likely to confer a specific morphology at the bone–tendon and bone–ligament interfaces at the ear ossicles, which therefore represent an exciting target of enthesis research. We histologically examined (i) the bone attachments of the tensor tympani and stapedius muscles and (ii) the annular ligament of the incudostapedial joint obtained from seven elderly donated cadavers. Notably, both aldehyde-fuchsin and elastic-Masson staining demonstrated that the major fibrous component of the entheses was not collagen fibers but mature elastic fibers. The positive controls for elastic fiber staining were the arterial wall elastic laminae included in the temporal bone materials. The elastic fibers were inserted deeply into the type II collagen-poor fibrocartilage covering the ear ossicles. The muscle tendons were composed of an outer thin layer of collagen fibers and an inner thick core of elastic fibers near the malleus or stapes. In the unique elastic fiber-mediated entheses, hyaluronan, versican and fibronectin were expressed strongly along the elastic fibers. The hyaluronan seemed to act as a friction-reducing lubricant for the elastic fibers. Aggrecan was labeled strongly in a disk- or plica-like fibrous mass on the inner side of the elastic fiber-rich ligament, possibly due to compression stress from the ligament. Tenascin-c was not evident in the entheses. The elastic fiber-mediated entheses appeared resistant to tissue destruction in an environment exposed to constant vibration. The morphology was unlikely to be the result of age-related degeneration. PMID:22803514

  10. Non-ototoxic local delivery of bisphosphonate to the mammalian cochlea

    PubMed Central

    Kang, Woo Seok; Sun, Shuting; Nguyen, Kim; Kashemirov, Boris; McKenna, Charles E.; Hacking, S. Adam; Quesnel, Alicia M.; Sewell, William F.; McKenna, Michael J.; Jung, David H.

    2015-01-01

    Hypothesis Local delivery of bisphosphonates results in superior localization of these compounds for the treatment of cochlear otosclerosis, without ototoxicity. Background Otosclerosis is a common disorder of abnormal bone remodeling within the human otic capsule. It is a frequent cause of conductive hearing loss from stapes fixation. Large lesions that penetrate the cochlear endosteum and injure the spiral ligament result in sensorineural hearing loss. Nitrogen-containing bisphosphonates (e.g., zoledronate) are potent inhibitors of bone remodeling with proven efficacy in the treatment of metabolic bone diseases, including otosclerosis. Local delivery to the cochlea may allow for improved drug targeting, higher local concentrations, and the avoidance of systemic complications. In this study, we utilize a fluorescently labeled bisphosphonate compound (6-FAM-ZOL) to determine drug localization and concentration within the otic capsule. Various methods for delivery are compared. Ototoxicity is evaluated by ABR and DPOAEs. Methods 6-FAM-ZOL was administered to guinea pigs via intraperitoneal injection, placement of alginate beads onto the round window membrane (RWM), or microfluidic pump infusion via a cochleostomy. Hearing was evaluated. Specimens were embedded into resin blocks, ground to a mid-modiolar section, and quantitatively imaged using fluorescence microscopy. Results There was a dose-dependent increase in fluorescent signal following systemic 6-FAM-ZOL treatment. Local delivery via the RWM or a cochleostomy increased delivery efficiency. No significant ototoxicity was observed following either systemic or local 6-FAM-ZOL delivery. Conclusions These findings establish important pre-clinical parameters for the treatment of cochlear otosclerosis in humans. PMID:25996080

  11. [How do metallic middle ear implants behave in the MRI?].

    PubMed

    Kwok, P; Waldeck, A; Strutz, J

    2003-01-01

    Magnetic resonance imaging (MRI) has gained in frequency and importance as a diagnostic procedure. In respect to the close anatomical relationship in the temporal bone it is necessary to know whether it is hazardous to patients with metallic middle ear implants regarding displacement and rise in temperature. For the MR image quality artefacts caused by metallic prostheses should be low. Four different stapes prostheses made from titanium, gold, teflon/platinum and teflon/steel, a titanium total ossicular reconstruction prosthesis (TORP) and two ventilation tubes (made from titanium and gold) were tested in a 1.5 Tesla MRI machine regarding their displacement. All objects were first placed in a petri dish, then suspended from a thread and finally immersed in a dish filled with Gadolinium. Temperature changes of the implants were recorded by a pyrometer. None of the implants moved when they were placed in the petri dish or suspended from the thread. On the water surface the teflon/platinum and the teflon/steel pistons adjusted their direction with their axis longitudinally to the MRI scanner opening and the teflon/steel piston floated towards the MRI-machine when put close enough to the scanner opening. No rise in temperature was recorded. All implants showed as little artefacts that would still make an evaluation of the surrounding tissue possible. Patients with any of the metallic middle ear implants that were examined in this study may undergo MRI-investigations without significant adverse effects.

  12. Comparison of lasers used in stapedotomy using specialized visualization techniques for mechanical and thermal effects in an inner ear model

    NASA Astrophysics Data System (ADS)

    Kamalski, Digna M. A.; Verdaasdonk, Rudolf M.; de Boorder, Tjeerd; Grolman, Wilko

    2011-03-01

    The outcome of stapedotomy depends on several surgical steps. Using laser light, the ossicular chain can be handled and the oval window can be punctured with a non-touch method. Various lasers are being used or considered, however, it is not clear which settings and characteristics will contribute to optimal or adverse effects (vestibule damage and loss hearing frequencies). Using a unique high speed thermal imaging setup based on Schlieren techniques, the mechanical and thermal effects during laser stapedotomy were studied in an inner ear model consisting of human, fresh frozen stapes positioned on a liquid filled cavity in a gel cast. The cw KTP (532 nm), cw CO2 (10.6 μm), cw Thulium (2.0 μm), pulsed Er,Cr;YSGG (2.78 μm) coupled to special fiber delivery systems were applied at typical clinical settings for comparison. The imaging techniques provided a good insight in the extent of heat conduction beneath the footplate and (explosive) vapour formation on both sides. For the pulsed laser modes, explosive vapour expansion can to be controlled with optimized pulse energies while for continuous wave lasers the thermal effects can be controlled with the pulse length and repetition rate. The fluence at the tip of the delivery system and the distance to the footplate has a major impact on the ablation effect. The pulsed IR lasers with fiber delivery show to be promising for a controlled stapedotomy.

  13. Monitoring blood-flow in the mouse cochlea using an endoscopic laser speckle contrast imaging system

    PubMed Central

    Yu, Sunkon; Jung, Byungjo; Choi, Jin Sil

    2018-01-01

    Laser speckle contrast imaging (LSCI) enables continuous high-resolution assessment of microcirculation in real-time. We applied an endoscope to LSCI to measure cochlear blood-flow in an ischemia–reperfusion mouse model. We also explored whether using xenon light in combination with LSCI facilitates visualization of anatomical position. Based on a previous preliminary study, the appropriate wavelength for penetrating the thin bony cochlea was 830 nm. A 2.7-mm-diameter endoscope was used, as appropriate for the size of the mouse cochlea. Our endoscopic LSCI system was used to illuminate the right cochlea after dissection of the mouse. We observed changes in the speckle signals when we applied the endoscopic LSCI system to the ischemia-reperfusion mouse model. The anatomical structure of the mouse cochlea and surrounding structures were clearly visible using the xenon light. The speckle signal of the cochlea was scattered, with an intensity that varied between that of the stapes (with the lowest signal), the negative control, and the stapedial artery (with the highest signal), the positive control. In the cochlear ischemia–reperfusion mouse model, the speckle signal of the cochlea decreased during the ischemic phase, and increased during the reperfusion phase, clearly reflecting cochlear blood-flow. The endoscopic LSCI system generates high-resolution images in real-time, allowing visualization of blood-flow and its changes in the mouse cochlea. Anatomical structures were clearly matched using LSCI along with visible light. PMID:29489849

  14. Monitoring blood-flow in the mouse cochlea using an endoscopic laser speckle contrast imaging system.

    PubMed

    Kong, Tae Hoon; Yu, Sunkon; Jung, Byungjo; Choi, Jin Sil; Seo, Young Joon

    2018-01-01

    Laser speckle contrast imaging (LSCI) enables continuous high-resolution assessment of microcirculation in real-time. We applied an endoscope to LSCI to measure cochlear blood-flow in an ischemia-reperfusion mouse model. We also explored whether using xenon light in combination with LSCI facilitates visualization of anatomical position. Based on a previous preliminary study, the appropriate wavelength for penetrating the thin bony cochlea was 830 nm. A 2.7-mm-diameter endoscope was used, as appropriate for the size of the mouse cochlea. Our endoscopic LSCI system was used to illuminate the right cochlea after dissection of the mouse. We observed changes in the speckle signals when we applied the endoscopic LSCI system to the ischemia-reperfusion mouse model. The anatomical structure of the mouse cochlea and surrounding structures were clearly visible using the xenon light. The speckle signal of the cochlea was scattered, with an intensity that varied between that of the stapes (with the lowest signal), the negative control, and the stapedial artery (with the highest signal), the positive control. In the cochlear ischemia-reperfusion mouse model, the speckle signal of the cochlea decreased during the ischemic phase, and increased during the reperfusion phase, clearly reflecting cochlear blood-flow. The endoscopic LSCI system generates high-resolution images in real-time, allowing visualization of blood-flow and its changes in the mouse cochlea. Anatomical structures were clearly matched using LSCI along with visible light.

  15. 3D finite element model of the chinchilla ear for characterizing middle ear functions

    PubMed Central

    Wang, Xuelin; Gan, Rong Z.

    2016-01-01

    Chinchilla is a commonly used animal model for research of sound transmission through the ear. Experimental measurements of the middle ear transfer function in chinchillas have shown that the middle ear cavity greatly affects the tympanic membrane (TM) and stapes footplate (FP) displacements. However, there is no finite element (FE) model of the chinchilla ear available in the literature to characterize the middle ear functions with the anatomical features of the chinchilla ear. This paper reports a recently completed 3D FE model of the chinchilla ear based on X-ray micro-computed tomography images of a chinchilla bulla. The model consisted of the ear canal, TM, middle ear ossicles and suspensory ligaments, and the middle ear cavity. Two boundary conditions of the middle ear cavity wall were simulated in the model as the rigid structure and the partially flexible surface, and the acoustic-mechanical coupled analysis was conducted with these two conditions to characterize the middle ear function. The model results were compared with experimental measurements reported in the literature including the TM and FP displacements and the middle ear input admittance in chinchilla ear. An application of this model was presented to identify the acoustic role of the middle ear septa - a unique feature of chinchilla middle ear cavity. This study provides the first 3D FE model of the chinchilla ear for characterizing the middle ear functions through the acoustic-mechanical coupled FE analysis. PMID:26785845

  16. [Study of radiation dose to the eye lens by multi-detector row computed tomography of the temporal bone].

    PubMed

    Hirakuri, Ayaka; Numasawa, Kanako; Takeishi, Hideki; Satomura, Minato; Takeda, Hiromitsu; Harada, Kuniaki; Asanuma, Osamu; Sakata, Motomichi

    2012-01-01

    The exposure of the eye lens caused by multi-detector row computed tomography (MDCT) of the temporal bone is a serious problem. Our aim was to evaluate the radiation dose to the eye lens by different scan baselines (orbitomeatal line; OML, acanthiomeatal line; AML) and examine the difference of the depiction of the temporal bone structures. Measurement of the exposure to the eye lens was performed by means of MDCT of the temporal bone with a radio-photoluminescence glass dosimeter using a rand phantom. Moreover, we studied only one volunteer (58-year-old male) who had no symptom and was not suspected of having any ear abnormalities with a two scan baseline. Visualization of the major anatomical structures of the temporal bone (the tympanic portion of the facial nerve canal, the body of the incus, stapes superstructures, vestibule etc.) was performed on the volunteer. The average absorbed dose was 6.42 mGy by the OML and 1.59 mGy by the AML, respectively. With regard to visualization of the temporal bone structures, all structures were of equal quality with the two scan baseline. With the AML line, the radiation dose to the eye lens was reduced to 75%. Therefore, the authors recommended an AML for use for MDCT of the temporal bone. In clinical practice, the optimization of scanning factor (kVp, mAs etc.) and the use of the radio-protection should be implemented for radiation dose reduction of the eye lens by MDCT of the temporal bone.

  17. Effects of Skin Thickness on Cochlear Input Signal using Transcutaneous Bone Conduction Implants

    PubMed Central

    Mattingly, Jameson K.; Greene, Nathaniel T.; Jenkins, Herman A.; Tollin, Daniel J.; Easter, James R.; Cass, Stephen P.

    2015-01-01

    Hypothesis Intracochlear sound pressures (PIC) and velocity measurements of the stapes, round window, and promontory (VStap/RW/Prom) will show frequency dependent attenuation using magnet-based, transcutaneous bone-conduction implants (TCBCI) in comparison to direct-connect, skin-penetrating implants (DCBCI). Background TCBCIs have recently been introduced as alternatives to DCBCIs. Clinical studies have demonstrated elevated high-frequency thresholds for TCBCIs as compared to DCBCIs; however, little data exists examining the direct effect of skin thickness on the cochlear input signal using TCBCIs. Methods Using seven cadveric heads, PIC was measured in the scala vestibuli and tympani with fiber-optic pressure sensors concurrently with VStap/RW/Prom via laser Doppler vibrometry. Ipsilateral titanium implant fixtures were placed and connected to either a DCBCI or TCBCI. Soft tissue flaps with varying thicknesses (no flap, 3, 6, and 9 mm) were placed successively between the magnetic plate and sound processor magnet. A bone-conduction transducer coupled to custom software provided pure tone stimuli between 120 to 10240 Hz. Results Stimulation via the DCBCI produced the largest response magnitudes. The TCBCI showed similar PSV/ST and VStap/RW/Prom with no intervening flap, and a frequency-dependent, non-linear reduction of magnitude with increasing flap thickness. Phase shows a comparable dependence on transmission delay as the acoustic baseline, and the slope steepens at higher frequencies as flap thickness increases suggesting a longer group delay. Conclusions Proper soft tissue management is critical to optimize the cochlear input signal. The skin thickness related effects on cochlear response magnitudes should be taken into account when selecting patients for a TCBCI. PMID:26164446

  18. Transmission of infrasonic pressure waves from cerebrospinal to intralabyrinthine fluids through the human cochlear aqueduct: Non-invasive measurements with otoacoustic emissions.

    PubMed

    Traboulsi, Raghida; Avan, Paul

    2007-11-01

    The cochlear aqueduct connecting intralabyrinthine and cerebrospinal fluids (CSF) acts as a low-pass filter that should be able to transmit infrasonic pressure waves from CSF to cochlea. Recent experiments have shown that otoacoustic emissions generated at 1kHz respond to pressure-related stapes impedance changes with a change in phase relative to the generator tones, and provide a non-invasive means of assessing intracochlear pressure changes. In order to characterize the transmission to the cochlea of CSF pressure waves due to respiration, the distortion-product otoacoustic emissions (DPOAE) of 12 subjects were continuously monitored around 1kHz at a rate of 6.25epochs/s, and their phase relative to the stimulus tones was extracted. The subjects breathed normally, in different postures, while thoracic movements were recorded so as to monitor respiration. A correlate of respiration was found in the time variation of DPOAE phase, with an estimated mean amplitude of 10 degrees , i.e. 60mm water, suggesting little attenuation across the aqueduct. Its phase lag relative to thoracic movements varied between 0 degrees and -270 degrees . When fed into a two-compartment model of CSF and labyrinthine spaces, these results suggest that respiration rate at rest is just above the resonance frequency of the CSF compartment, and just below the corner frequency of the cochlear-aqueduct low-pass filter, in line with previous estimates from temporal bone and intracranial measurements. The fact that infrasonic CSF waves can be monitored through the cochlea opens diagnostic possibilities in neurology.

  19. A missense mutation in Fgfr1 causes ear and skull defects in hush puppy mice.

    PubMed

    Calvert, Jennifer A; Dedos, Skarlatos G; Hawker, Kelvin; Fleming, Michelle; Lewis, Morag A; Steel, Karen P

    2011-06-01

    The hush puppy mouse mutant has been shown previously to have skull and outer, middle, and inner ear defects, and an increase in hearing threshold. The fibroblast growth factor receptor 1 (Fgfr1) gene is located in the region of chromosome 8 containing the mutation. Sequencing of the gene in hush puppy heterozygotes revealed a missense mutation in the kinase domain of the protein (W691R). Homozygotes were found to die during development, at approximately embryonic day 8.5, and displayed a phenotype similar to null mutants. Reverse transcription PCR indicated a decrease in Fgfr1 transcript in heterozygotes and homozygotes. Generation of a construct containing the mutation allowed the function of the mutated receptor to be studied. Immunocytochemistry showed that the mutant receptor protein was present at the cell membrane, suggesting normal expression and trafficking. Measurements of changes in intracellular calcium concentration showed that the mutated receptor could not activate the IP(3) pathway, in contrast to the wild-type receptor, nor could it initiate activation of the Ras/MAP kinase pathway. Thus, the hush puppy mutation in fibroblast growth factor receptor 1 appears to cause a loss of receptor function. The mutant protein appears to have a dominant negative effect, which could be due to it dimerising with the wild-type protein and inhibiting its activity, thus further reducing the levels of functional protein. A dominant modifier, Mhspy, which reduces the effect of the hush puppy mutation on pinna and stapes development, has been mapped to the distal end of chromosome 7 and may show imprinting.

  20. Hush puppy: a new mouse mutant with pinna, ossicle, and inner ear defects.

    PubMed

    Pau, Henry; Fuchs, Helmut; de Angelis, Martin Hrabé; Steel, Karen P

    2005-01-01

    Deafness can be associated with abnormalities of the pinna, ossicles, and cochlea. The authors studied a newly generated mouse mutant with pinna defects and asked whether these defects are associated with peripheral auditory or facial skeletal abnormalities, or both. Furthermore, the authors investigated where the mutation responsible for these defects was located in the mouse genome. The hearing of hush puppy mutants was assessed by Preyer reflex and electrophysiological measurement. The morphological features of their middle and inner ears were investigated by microdissection, paint-filling of the labyrinth, and scanning electron microscopy. Skeletal staining of skulls was performed to assess the craniofacial dimensions. Genome scanning was performed using microsatellite markers to localize the mutation to a chromosomal region. Some hush puppy mutants showed early onset of hearing impairment. They had small, bat-like pinnae and normal malleus but abnormal incus and stapes. Some mutants had asymmetrical defects and showed reduced penetrance of the ear abnormalities. Paint-filling of newborns' inner ears revealed no morphological abnormality, although half of the mice studied were expected to carry the mutation. Reduced numbers of outer hair cells were demonstrated in mutants' cochlea on scanning electron microscopy. Skeletal staining showed that the mutants have significantly shorter snouts and mandibles. Genome scan revealed that the mutation lies on chromosome 8 between markers D8Mit58 and D8Mit289. The study results indicate developmental problems of the first and second branchial arches and otocyst as a result of a single gene mutation. Similar defects are found in humans, and hush puppy provides a mouse model for investigation of such defects.

  1. Comparing mechanical effects and sound production of KTP, thulium, and CO2 laser in stapedotomy.

    PubMed

    Kamalski, Digna M A; Verdaasdonk, Rudolf M; de Boorder, Tjeerd; Vincent, Robert; Versnel, Huib; Grolman, Wilko

    2014-08-01

    The mechanical and acoustic effects that occur during laser-assisted stapedotomy differ among KTP, CO2, and thulium lasers. Making a fenestration in stapedotomy with a laser minimizes the risk of a floating footplate caused by mechanical forces. Theoretically, the lasers used in stapedotomy could inflict mechanical trauma because of absorption in the perilymph, causing vaporization bubbles. These bubbles can generate a shock wave, when imploding. In an inner ear model, we made a fenestration in a fresh human stapes with KTP, CO2, and thulium laser. During the fenestration, we performed high-speed imaging from different angles to capture mechanical effects. The sounds produced by the fenestration were recorded simultaneously with a hydrophone; these recordings were compared with acoustics produced by a conventional microburr fenestration. KTP laser fenestration showed little mechanical effects, with minimal sound production. With CO2 laser, miniscule bubbles arose in the vestibule; imploding of these bubbles corresponded to the acoustics. Thulium laser fenestration showed large bubbles in the vestibule, with a larger sound production than the other two lasers. Each type of laser generated significantly less noise than the microburr. The microburr maximally reached 95 ± 7 dB(A), compared with 49 ± 8 dB(A) for KTP, 68 ± 4 dB(A) for CO2, and 83 ± 6 dB(A) for thulium. Mechanical and acoustic effects differ among lasers used for stapedotomy. Based on their relatively small effects, KTP and CO2 lasers are preferable to thulium laser.

  2. Cochlear Implant Electrode Effect on Sound Energy Transfer within the Cochlea during Acoustic Stimulation

    PubMed Central

    Greene, Nathaniel T.; Mattingly, Jameson K.; Jenkins, Herman A.; Tollin, Daniel J.; Easter, James R.; Cass, Stephen P.

    2015-01-01

    Hypothesis Cochlear implants (CI) designed for hearing preservation will not alter mechanical properties of the middle and inner ear as measured by intracochlear pressure (PIC) and stapes velocity (Vstap). Background CIs designed to provide combined electrical and acoustic stimulation (EAS) are now available. To maintain functional acoustic hearing, it is important to know if a CI electrode can alter middle or inner ear mechanics, as any alteration could contribute to elevated low-frequency thresholds in EAS patients. Methods Seven human cadaveric temporal bones were prepared, and pure-tone stimuli from 120Hz–10kHz were presented at a range of intensities up to 110 dB SPL. PIC in the scala vestibuli (PSV) and tympani (PST) were measured with fiber-optic pressure sensors concurrently with VStap using laser Doppler vibrometry. Five CI electrodes from two different manufacturers, with varying dimensions were inserted via a round window approach at six different depths (16–25 mm). Results The responses of PIC and VStap to acoustic stimulation were assessed as a function of stimulus frequency, normalized to SPL in the external auditory canal (EAC), in baseline and electrode inserted conditions. Responses measured with electrodes inserted were generally within ~5 dB of baseline, indicating little effect of cochlear implant electrode insertion on PIC and VStap. Overall, mean differences across conditions were small for all responses, and no substantial differences were consistently visible across electrode types. Conclusions Results suggest that the influence of a CI electrode on middle and inner ear mechanics is minimal, despite variation in electrode lengths and configurations. PMID:26333018

  3. Elastic fiber-mediated enthesis in the human middle ear.

    PubMed

    Kawase, Tetsuaki; Shibata, Shunichi; Katori, Yukio; Ohtsuka, Aiji; Murakami, Gen; Fujimiya, Mineko

    2012-10-01

    Adaptation to constant vibration (acoustic oscillation) is likely to confer a specific morphology at the bone-tendon and bone-ligament interfaces at the ear ossicles, which therefore represent an exciting target of enthesis research. We histologically examined (i) the bone attachments of the tensor tympani and stapedius muscles and (ii) the annular ligament of the incudostapedial joint obtained from seven elderly donated cadavers. Notably, both aldehyde-fuchsin and elastic-Masson staining demonstrated that the major fibrous component of the entheses was not collagen fibers but mature elastic fibers. The positive controls for elastic fiber staining were the arterial wall elastic laminae included in the temporal bone materials. The elastic fibers were inserted deeply into the type II collagen-poor fibrocartilage covering the ear ossicles. The muscle tendons were composed of an outer thin layer of collagen fibers and an inner thick core of elastic fibers near the malleus or stapes. In the unique elastic fiber-mediated entheses, hyaluronan, versican and fibronectin were expressed strongly along the elastic fibers. The hyaluronan seemed to act as a friction-reducing lubricant for the elastic fibers. Aggrecan was labeled strongly in a disk- or plica-like fibrous mass on the inner side of the elastic fiber-rich ligament, possibly due to compression stress from the ligament. Tenascin-c was not evident in the entheses. The elastic fiber-mediated entheses appeared resistant to tissue destruction in an environment exposed to constant vibration. The morphology was unlikely to be the result of age-related degeneration. © 2012 The Authors Journal of Anatomy © 2012 Anatomical Society.

  4. MRI information for commonly used otologic implants: review and update.

    PubMed

    Azadarmaki, Roya; Tubbs, Rhonda; Chen, Douglas A; Shellock, Frank G

    2014-04-01

    To review information on magnetic resonance imaging (MRI) issues for commonly used otologic implants. Manufacturing companies, National Library of Medicine's online database, and an additional online database (www.MRIsafety.com). A literature review of the National Library of Medicine's online database with focus on MRI issues for otologic implants was performed. The MRI information on implants provided by manufacturers was reviewed. Baha and Ponto Pro osseointegrated implants' abutment and fixture and the implanted magnet of the Sophono Alpha 1 and 2 abutment-free systems are approved for 3-Tesla magnetic resonance (MR) systems. The external processors of these devices are MR Unsafe. Of the implants tested, middle ear ossicular prostheses, including stapes prostheses, except for the 1987 McGee prosthesis, are MR Conditional for 1.5-Tesla (and many are approved for 3-Tesla) MR systems. Cochlear implants with removable magnets are approved for patients undergoing MRI at 1.5 Tesla after magnet removal. The MED-EL PULSAR, SONATA, CONCERT, and CONCERT PIN cochlear implants can be used in patients undergoing MRI at 1.5 Tesla with application of a protective bandage. The MED-EL COMBI 40+ can be used in 0.2-Tesla MR systems. Implants made from nonmagnetic and nonconducting materials are MR Safe. Knowledge of MRI guidelines for commonly used otologic implants is important. Guidelines on MRI issues approved by the US Food and Drug Administration are not always the same compared with other parts of the world. This monograph provides a current reference for physicians on MRI issues for commonly used otologic implants.

  5. Impact of coupling techniques of an active middle ear device to the round window membrane for the backward stimulation of the cochlea.

    PubMed

    Gostian, Antoniu-Oreste; Pazen, David; Ortmann, Magdalene; Luers, Jan-Christoffer; Anagiotos, Andreas; Hüttenbrink, Karl-Bernd; Beutner, Dirk

    2015-01-01

    Interposed cartilage and the round window coupler (RWC) increase the efficiency of cochlea stimulation with the floating mass transducer (FMT) of a single active middle ear implant (AMEI) placed against the round window membrane. Treatment of mixed and conductive hearing loss with an AMEI attached to the round window is effective, yet the best placement technique of its FMT for the most efficient stimulation of the cochlea remains to be determined. Experimental study on human temporal bones with the FMT placed against firstly the unaltered round window niche and then subsequently against the fully exposed round window membrane with and without interposed cartilage and the RWC. Cochlea stimulation is measured by the volume velocities of the stapes footplate using LASER vibrometry. At the undrilled round window niche, placement of the FMT by itself and with the RWC resulted in similar volume velocities. The response was significantly raised by interposing cartilage into the undrilled round window niche. Complete exposure of the round window membrane allowed for significantly increased volume velocities. Among these, coupling of the FMT with interposed cartilage yielded responses of similar magnitude compared with the RWC but significantly higher compared with the FMT by itself. Good contact to the round window membrane is essential for efficient stimulation of the cochlea. Therefore, interposing cartilage into the undrilled round window niche is a viable option. At the drilled round window membrane, the FMT with interposed cartilage and attached to the RWC are similarly effective.

  6. Trans-Oval-Window Implants, A New Approach for Drug Delivery to the Inner Ear: Extended Dexamethasone Release From Silicone-based Implants.

    PubMed

    Sircoglou, Julie; Gehrke, Maria; Tardivel, Meryem; Siepmann, Florence; Siepmann, Juergen; Vincent, Christophe

    2015-09-01

    The purpose of this study was to develop a new strategy to deliver drugs to the inner ear from dexamethasone (DXM)-loaded silicone implants and to evaluate the distribution of the drug in the cochlea with confocal microscopy. Systemic drug administration for the treatment of inner ear disorders is tricky because of the blood-cochlear barrier, a difficult anatomical access, the small size of the cochlea, and can cause significant adverse effects. An effective way to overcome these obstacles is to administer drugs locally. In vitro, the drug release from DXM-loaded silicone-based thin films and tiny implants into artificial perilymph was thoroughly analyzed by high-performance liquid chromatography. In vivo, a silicone implant loaded with 10% DXM and 5% polyethylene glycol 400 was implanted next to the stapes's footplate of gerbils. Delivery of DXM into the inner ear was proved by confocal microscopy imaging of the whole cochlea and the organ of Corti. The study showed a continuous and prolonged release during 90 days in vitro. This was confirmed by confocal microscopy that allowed detection of DXM by fluorescence labeling in the cell body of the hair cells for at least 30 days. Interestingly, fluorescence was already observed after 20 minutes of implantation, reached a climax at day 7, and could still be detected 30 days after implantation. Thus, we developed a new device for local corticosteroids delivery into the oval window with an extended drug release of DXM to the inner ear.

  7. Semicircular Canal Pressure Changes During High-intensity Acoustic Stimulation.

    PubMed

    Maxwell, Anne K; Banakis Hartl, Renee M; Greene, Nathaniel T; Benichoux, Victor; Mattingly, Jameson K; Cass, Stephen P; Tollin, Daniel J

    2017-08-01

    Acoustic stimulation generates measurable sound pressure levels in the semicircular canals. High-intensity acoustic stimuli can cause hearing loss and balance disruptions. To examine the propagation of acoustic stimuli to the vestibular end-organs, we simultaneously measured fluid pressure in the cochlea and semicircular canals during both air- and bone-conducted sound presentation. Five full-cephalic human cadaveric heads were prepared bilaterally with a mastoidectomy and extended facial recess. Vestibular pressures were measured within the superior, lateral, and posterior semicircular canals, and referenced to intracochlear pressure within the scala vestibuli with fiber-optic pressure probes. Pressures were measured concurrently with laser Doppler vibrometry measurements of stapes velocity during stimulation with both air- and bone-conduction. Stimuli were pure tones between 100 Hz and 14 kHz presented with custom closed-field loudspeakers for air-conducted sounds and via commercially available bone-anchored device for bone-conducted sounds. Pressures recorded in the superior, lateral, and posterior semicircular canals in response to sound stimulation were equal to or greater in magnitude than those recorded in the scala vestibuli (up to 20 dB higher). The pressure magnitudes varied across canals in a frequency-dependent manner. High sound pressure levels were recorded in the semicircular canals with sound stimulation, suggesting that similar acoustical energy is transmitted to the semicircular canals and the cochlea. Since these intralabyrinthine pressures exceed intracochlear pressure levels, our results suggest that the vestibular end-organs may also be at risk for injury during exposure to high-intensity acoustic stimuli known to cause trauma in the auditory system.

  8. Comparison of KTP, Thulium, and CO2 laser in stapedotomy using specialized visualization techniques: thermal effects.

    PubMed

    Kamalski, Digna M A; Verdaasdonk, Rudolf M; de Boorder, Tjeerd; Vincent, Robert; Trabelzini, Franco; Grolman, Wilko

    2014-06-01

    High-speed thermal imaging enables visualization of heating of the vestibule during laser-assisted stapedotomy, comparing KTP, CO2, and Thulium laser light. Perforation of the stapes footplate with laser bears the risk of heating of the inner ear fluids. The amount of heating depends on absorption of the laser light and subsequent tissue ablation. The ablation of the footplate is driven by strong water absorption for the CO2 and Thulium laser. For the KTP laser wavelength, ablation is driven by carbonization of the footplate and it might penetrate deep into the inner ear without absorption in water. The thermal effects were visualized in an inner ear model, using two new techniques: (1) high-speed Schlieren imaging shows relative dynamic changes of temperatures up to 2 ms resolution in the perilymph. (2) Thermo imaging provides absolute temperature measurements around the footplate up to 40 ms resolution. The high-speed Schlieren imaging showed minimal heating using the KTP laser. Both CO2 and Thulium laser showed heating below the footplate. Thulium laser wavelength generated heating up to 0.6 mm depth. This was confirmed with thermal imaging, showing a rise of temperature of 4.7 (±3.5) °C for KTP and 9.4 (±6.9) for Thulium in the area of 2 mm below the footplate. For stapedotomy, the Thulium and CO2 laser show more extended thermal effects compared to KTP. High-speed Schlieren imaging and thermal imaging are complimentary techniques to study lasers thermal effects in tissue.

  9. La Ferrassie 1: New perspectives on a "classic" Neandertal.

    PubMed

    Gómez-Olivencia, Asier; Quam, Rolf; Sala, Nohemi; Bardey, Morgane; Ohman, James C; Balzeau, Antoine

    2018-04-01

    The La Ferrassie 1 (LF1) skeleton, discovered over a century ago, is one of the most important Neandertal individuals both for its completeness and due to the role it has played historically in the interpretation of Neandertal anatomy and lifeways. Here we present new skeletal remains from this individual, which include a complete right middle ear ossicular chain (malleus, incus, and stapes), three vertebral fragments, and two costal remains. Additionally, the study of the skeleton has allowed us to identify new pathological lesions, including a congenital variant in the atlas, a greenstick fracture of the left clavicle, and a lesion in a mid-thoracic rib of unknown etiology. In addition, we have quantified the amount of vertebral pathology, which is greater than previously appreciated. We have complemented the paleopathological analysis with a taphonomic analysis to identify any potential perimortem fractures. The taphonomic analysis indicates that no surface alteration is present in the LF1 skeleton and that the breakage pattern is that of bone that has lost collagen, which would be consistent with the intentional burial of this individual proposed by previous researchers. In this study, we used CT and microCT scans in order to discover new skeletal elements to better characterize the pathological lesions and to quantify the fracture orientation of those bones in which the current plaster reconstruction did not allow its direct visualization, which underlines the broad potential of imaging technologies in paleoanthropological research. A century after its discovery, LF1 is still providing new insights into Neandertal anatomy and behavior. Copyright © 2018 Elsevier Ltd. All rights reserved.

  10. Traumatic dislocation of the incudostapedial joint repaired with fibrin tissue adhesive.

    PubMed

    Nikolaidis, Vasilios

    2011-03-01

    We present a case of traumatic dislocation of the incudostapedial joint (ISJ) and a simple method for controlled application of the glue using commercial fibrin tissue adhesive. A 26-year-old female presented to our ENT clinic for hearing impairment to her left ear 2 months after a head trauma due to a motorcycle accident. The audiogram revealed a 40- to 50-dB HL conductive hearing loss with a notch configuration in bone conduction curve on the left ear. Computed tomography of the left temporal bone revealed a longitudinal fracture line. An exploratory tympanotomy was performed under general anesthesia. The ISJ was found dislocated while the incus was trapped by the edges of the bony lateral attic wall fracture. A small bony edge that impeded incus movement was removed and a small amount of the glue was precisely applied to the lenticular process of the incus with an angled incision knife. The long process of the incus was firmly pressed over the stapes for 30 seconds with a 90° hook and 60 seconds after the application of the glue the ISJ was repaired. One year after our patient achieved full airbone gap (ABG) closure (ABG, ≤10 dB HL), while she demonstrated overclosure in frequencies 2 and 4 kHz. Fibrin tissue glue allowed safe, rapid, and accurate repair of the ISJ and resulted in an anatomically normal articulation as the mass and shape of the ossicles was preserved. Moreover, our patient achieved full ABG closure. Copyright © 2011 The American Laryngological, Rhinological, and Otological Society, Inc.

  11. Enhanced Wound Healing Using Topically Administered Nanoparticle Encapsulated siRNA

    DTIC Science & Technology

    2013-11-01

    from eye surgery such as LASIK surgery, LASEK surgery, PRK surgery, glaucoma filtration surgery, cataract surgery, or surgery in which the lens...treatment vs . siRNA transfection using the RNAiMAX delivery system from InVitrogen (http://www.invitrogen.com/site/us/en/home/Products-and- Services...consisting of: wounds of the skin; wounds of the eye (including the inhibition of scarring resulting from eye surgery such as LASIK surgery, LASEK surgery

  12. Increased ICU resource needs for an academic emergency general surgery service*.

    PubMed

    Lissauer, Matthew E; Galvagno, Samuel M; Rock, Peter; Narayan, Mayur; Shah, Paulesh; Spencer, Heather; Hong, Caron; Diaz, Jose J

    2014-04-01

    ICU needs of nontrauma emergency general surgery patients are poorly described. This study was designed to compare ICU utilization of emergency general surgery patients admitted to an acute care emergency surgery service with other general surgery patients. Our hypothesis is that tertiary care emergency general surgery patients utilize more ICU resources than other general surgical patients. Retrospective database review. Academic, tertiary care, nontrauma surgical ICU. All patients admitted to the surgical ICU over age 18 between March 2004 and June 2012. None. Six thousand ninety-eight patients were evaluated: 1,053 acute care emergency surgery, 1,964 general surgery, 1,491 transplant surgery, 995 facial surgery/otolaryngology, and 595 neurosurgery. Acute care emergency surgery patients had statistically significantly longer ICU lengths of stay than other groups: acute care emergency surgery (13.5 ± 17.4 d) versus general surgery (8.7 ± 12.9), transplant (7.8 ± 11.6), oral-maxillofacial surgery (5.5 ± 4.2), and neurosurgery (4.47 ± 9.8) (all p< 0.01). Ventilator usage, defined by percentage of total ICU days patients required mechanical ventilation, was significantly higher for acute care emergency surgery patients: acute care emergency surgery 73.4% versus general surgery 64.9%, transplant 63.3%, oral-maxillofacial surgery 58.4%, and neurosurgery 53.1% (all p < 0.01). Continuous renal replacement therapy usage, defined as percent of patients requiring this service, was significantly higher in acute care emergency surgery patients: acute care emergency surgery 10.8% versus general surgery 4.3%, transplant 6.6%, oral-maxillofacial surgery 0%, and neurosurgery 0.5% (all p < 0.01). Acute care emergency surgery patients were more likely interhospital transfers for tertiary care services than general surgery or transplant (24.5% vs 15.5% and 8.3% respectively, p < 0.001 for each) and more likely required emergent surgery (13.7% vs 6.7% and 3.5%, all p < 0.001). Chronic comorbidities were similar between acute care emergency surgery and general surgery, whereas transplant had fewer. Emergency general surgery patients have increased ICU needs in terms of length of stay, ventilator usage, and continuous renal replacement therapy usage compared with other services, perhaps due to the higher percentage of transfers and emergent surgery required. These patients represent a distinct population. Understanding their resource needs will allow for better deployment of hospital resources.

  13. Improved Surgery Planning Using 3-D Printing: a Case Study.

    PubMed

    Singhal, A J; Shetty, V; Bhagavan, K R; Ragothaman, Ananthan; Shetty, V; Koneru, Ganesh; Agarwala, M

    2016-04-01

    The role of 3-D printing is presented for improved patient-specific surgery planning. Key benefits are time saved and surgery outcome. Two hard-tissue surgery models were 3-D printed, for orthopedic, pelvic surgery, and craniofacial surgery. We discuss software data conversion in computed tomography (CT)/magnetic resonance (MR) medical image for 3-D printing. 3-D printed models save time in surgery planning and help visualize complex pre-operative anatomy. Time saved in surgery planning can be as much as two thirds. In addition to improved surgery accuracy, 3-D printing presents opportunity in materials research. Other hard-tissue and soft-tissue cases in maxillofacial, abdominal, thoracic, cardiac, orthodontics, and neurosurgery are considered. We recommend using 3-D printing as standard protocol for surgery planning and for teaching surgery practices. A quick turnaround time of a 3-D printed surgery model, in improved accuracy in surgery planning, is helpful for the surgery team. It is recommended that these costs be within 20 % of the total surgery budget.

  14. Trend in otolaryngological surgeries in an era of super-aging: Descriptive statistics using a Japanese inpatient database.

    PubMed

    Suzuki, Sayaka; Yasunaga, Hideo; Matsui, Hiroki; Fushimi, Kiyohide; Yamasoba, Tatsuya

    2018-03-27

    To reveal the age distribution and capture the longitudinal trend in otolaryngological surgeries performed in Japan, where society is rapidly aging. Using the Diagnosis Procedure Combination database, we extracted data on patients who were hospitalized and underwent any type of otolaryngological surgery in departments of otolaryngology or head and neck surgery from fiscal year 2007 to fiscal year 2013. Type of surgery, patient's age, and fiscal year were compared. We categorized >200 types of surgeries into eight specialties: ear surgery, functional endoscopic sinus surgery (FESS), other types of paranasal surgery (except for malignancy), head and neck cancer surgery, benign tumor surgery, upper airway surgery (including pharynx and larynx), removal of foreign body, and other. In total, 558,732 patients were included. The proportions of patients in each age category formed two peaks in middle age and in children aged ≤9years. The proportion of all surgeries made up by FESS, other paranasal surgery, benign tumor surgery, and head and neck cancer surgery gradually increased with age, forming a peak in patients in their 60s. The proportion of ear surgery was highest in patients aged ≤9years (34.0% of all surgeries, mostly myringotomy and transtympanic ventilation tube insertion) and formed a gradual peak in patients in their 60s (mostly tympanoplasty). The proportion of upper airway surgery (tonsillectomy and adenoidectomy) was highest in patients aged ≤9years (25.3% of all surgeries). The proportion of foreign body removal was highest in patients aged ≤9years (52.2% of all surgeries) and increased slightly with age. In 2013, compared with 2007, those aged 65-74 years and ≥75years made up a larger percentage of patients undergoing each specific surgery, including tympanoplasty, stapedectomy/stapedotomy, FESS, head and neck cancer surgery, pharyngolaryngectomy, total/subtotal glossectomy, thyroid lobectomy, parotidectomy (for a benign tumor), submandibular gland resection, tonsillectomy, and vocal fold polypectomy. The age distribution of otolaryngological surgeries varied by specialty. We found an increased proportion of patients aged 65-74 and ≥75years in most specific surgeries. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Laparoscopic surgery for colorectal cancer is safe and has survival outcomes similar to those of open surgery in elderly patients with a poor performance status: subanalysis of a large multicenter case-control study in Japan.

    PubMed

    Niitsu, Hiroaki; Hinoi, Takao; Kawaguchi, Yasuo; Ohdan, Hideki; Hasegawa, Hirotoshi; Suzuka, Ichio; Fukunaga, Yosuke; Yamaguchi, Takashi; Endo, Shungo; Tagami, Soichi; Idani, Hitoshi; Ichihara, Takao; Watanabe, Kazuteru; Watanabe, Masahiko

    2016-01-01

    It remains controversial whether open or laparoscopic surgery should be indicated for elderly patients with colorectal cancer and a poor performance status. In those patients aged 80 years or older with Eastern Cooperative Oncology Group performance status score of 2 or greater who received elective surgery for stage 0 to stage III colorectal adenocarcinoma and had no concomitant malignancies and who were enrolled in a multicenter case-control study entitled "Retrospective study of laparoscopic colorectal surgery for elderly patients" that was conducted in Japan between 2003 and 2007, background characteristics and short-term and long-term outcomes for open surgery and laparoscopic surgery were compared. Of the 398 patients included, 295 underwent open surgery and 103 underwent laparoscopic surgery. There were no significant differences in the baseline characteristics between open surgery and laparoscopic surgery patients, except for previous abdominal surgery and TNM stage. The median operation duration was shorter with open surgery (open surgery, 153 min; laparoscopic surgery, 202 min; P < 0.001), and less blood loss occurred with laparoscopic surgery (median open surgery, 109 g; median laparoscopic surgery, 30 g; P < 0.001). An operation duration of 180 min or more (odds ratio, 1.97; 95 % confidence interval, 1.17-3.37; P = 0.011) and selection of laparoscopic surgery (odds ratio, 0.41; 95 % confidence interval, 0.22-0.75; P = 0.003) were statistically significant in the multivariate analysis for postoperative morbidity. Moreover, laparoscopic surgery did not result in an inferior overall survival rate compared with open surgery (log-rank test P = 0.289, 0.278, 0.346, 0.199, for all-stage, stage 0-I, stage II, and stage III disease, respectively). Laparoscopic surgery in elderly colorectal cancer patients with a poor performance status is safe and not inferior to open surgery in terms of overall survival.

  16. Simultaneous versus sequential penetrating keratoplasty and cataract surgery.

    PubMed

    Hayashi, Ken; Hayashi, Hideyuki

    2006-10-01

    To compare the surgical outcomes of simultaneous penetrating keratoplasty and cataract surgery with those of sequential surgery. Thirty-nine eyes of 39 patients scheduled for simultaneous keratoplasty and cataract surgery and 23 eyes of 23 patients scheduled for sequential keratoplasty and secondary phacoemulsification surgery were recruited. Refractive error, regular and irregular corneal astigmatism determined by Fourier analysis, and endothelial cell loss were studied at 1 week and 3, 6, and 12 months after combined surgery in the simultaneous surgery group or after subsequent phacoemulsification surgery in the sequential surgery group. At 3 and more months after surgery, mean refractive error was significantly greater in the simultaneous surgery group than in the sequential surgery group, although no difference was seen at 1 week. The refractive error at 12 months was within 2 D of that targeted in 15 eyes (39%) in the simultaneous surgery group and within 2 D in 16 eyes (70%) in the sequential surgery group; the incidence was significantly greater in the sequential group (P = 0.0344). The regular and irregular astigmatism was not significantly different between the groups at 3 and more months after surgery. No significant difference was also found in the percentage of endothelial cell loss between the groups. Although corneal astigmatism and endothelial cell loss were not different, refractive error from target refraction was greater after simultaneous keratoplasty and cataract surgery than after sequential surgery, indicating a better outcome after sequential surgery than after simultaneous surgery.

  17. [Present situation and prospect of enhanced recovery after surgery in pancreatic surgery].

    PubMed

    Feng, Mengyu; Zhang, Taiping; Zhao, Yupei

    2017-05-25

    Enhanced recovery after surgery is a multimodal perioperative strategy according to the evidence-based medicine and multidisciplinary collaboration, aiming to improve the restoration of functional capacity after surgery by reducing surgical stress, optimal control of pain, early oral diet and early mobilization. Compared with other sub-specialty in general surgery, pancreatic surgery is characterized by complex disease, highly difficult procedure and more postoperative complications. Accordingly, pancreatic surgery shares a slow development in enhanced recovery after surgery. In this review, the feasibility, safety, application progress, prospect and controversy of enhanced recovery after surgery in pancreatic surgery are discussed.

  18. Tennis elbow surgery

    MedlinePlus

    Lateral epicondylitis - surgery; Lateral tendinosis - surgery; Lateral tennis elbow - surgery ... Surgery to repair tennis elbow is often an outpatient surgery. This means you will not stay in the hospital overnight. You will be given ...

  19. Cosmetic Surgery

    MedlinePlus

    ... Body Looking and feeling your best Cosmetic surgery Cosmetic surgery Teens might have cosmetic surgery for a number ... about my body? What are the risks of cosmetic surgery? top People who have cosmetic surgery face many ...

  20. Periodontal surgery improves oral health-related quality of life in chronic periodontitis patients in Asian population.

    PubMed

    Chou, Yu-Hsiang; Yang, Yi-Hsin; Kuo, Hsiao-Ching; Ho, Kun-Yen; Wang, Wen-Chen; Hu, Kai-Fang

    2017-10-01

    The effect of periodontal surgery on patients' quality of life was investigated. Sixty patients received regenerative surgery or resective osseous surgery. Oral health-related quality of life and health-related quality of life instruments were used to assess the participants' quality of life before surgery and 4 weeks after surgery. Periodontal surgery can improve patients' quality of life by alleviating the physical pain and psychological discomfort. The scores were lower (more favorable) in the regenerative surgery group, and the functional limitations of the regenerative surgery group improved substantially compared with those of the resective osseous surgery group (P = 0.0421). The patients' oral health-related quality of life scores improved significantly after periodontal surgery. Clinicians can take advantage of the positive functional oral health-related quality of life impacts of regenerative surgery. Copyright © 2017. Published by Elsevier Taiwan.

  1. Orthopedic Surgery and Post-Operative Cognitive Decline in Idiopathic Parkinson’s Disease: Considerations from a Pilot Study

    PubMed Central

    Price, Catherine C.; Levy, Shellie-Anne; Tanner, Jared; Garvan, Cyndi; Ward, Jade; Akbar, Farheen; Bowers, Dawn; Rice, Mark; Okun, Michael

    2016-01-01

    BACKGROUND Post-operative cognitive dysfunction (POCD) demarks cognitive decline after major surgery but has been studied to date in “healthy” adults. Although individuals with neurodegenerative disorders such as Parkinson’s disease (PD) commonly undergo elective surgery, these individuals have yet to be prospectively followed despite hypotheses of increased POCD risk. OBJECTIVE To conduct a pilot study examining cognitive change pre-post elective orthopedic surgery for PD relative to surgery and non-surgery peers. METHODS A prospective one-year longitudinal design. No-dementia idiopathic PD individuals were actively recruited along with non-PD “healthy” controls (HC) undergoing knee replacement surgery. Non-surgical PD and HC controls were also recruited. Attention/processing speed, inhibitory function, memory recall, animal (semantic) fluency, and motor speed were assessed at baseline (pre-surgery), three-weeks, three-months, and one-year post- orthopedic surgery. Reliable change methods examined individual changes for PD individuals relative to control surgery and control non-surgery peers. RESULTS Over two years we screened 152 older adult surgery or non-surgery candidates with 19 of these individuals having a diagnosis of PD. Final participants included 8 PD (5 surgery, 3 non-surgery), 47 Control Surgery, and 21 Control Non-Surgery. Eighty percent (4 of the 5) PD surgery declined greater than 1.645 standard deviations from their baseline performance on measures assessing processing speed and inhibitory function. This was not observed for the non-surgery PD individuals. CONCLUSION This prospective pilot study demonstrated rationale and feasibility for examining cognitive decline in at-risk neurodegenerative populations. We discuss recruitment and design challenges for examining post-operative cognitive decline in neurodegenerative samples. PMID:26683785

  2. Bariatric Surgery vs. Conventional Dieting in the Morbidly Obese.

    PubMed

    Greenstein; Rabner; Taler

    1994-02-01

    Weight loss and psychosocial events have been compared between low calorie conventional diet (n = 11) or following obesity surgery (n = 17). Interviews were >/= 9 months following initiation of treatment. After surgery significantly less hunger was experienced (surgery 76% [13/17] vs diet 18% [2/11] p < 0.01) and less will-power was required to stop eating (surgery 88% [15/17] vs diet 27% [3/11] p < 0.001). More dieters stopped eating because of 'figure and health' (surgery 12 % [2/17] vs diet 64 % [7/11 ] p < 0.01) whereas postoperative patients stopped due to vomit avoidance (surgery 53% [9/17] vs diet 0% [0/11] p /= 9 months following surgery or beginning a conventional diet, the morbidly obese have a more positive response to surgery.

  3. Variability in Resident Operative Hand Experience by Specialty.

    PubMed

    Silvestre, Jason; Lin, Ines C; Levin, L Scott; Chang, Benjamin

    2018-01-01

    Recent attention has sought to standardize hand surgery training in the United States. This study analyzes the variability in operative hand experience for orthopedic and general surgery residents. Case logs for orthopedic and general surgery residency graduates were obtained from the American Council of Graduate Medical Education (2006-2007 to 2014-2015). Plastic surgery case logs were not available for comparison. Hand surgery case volumes were compared between specialties with parametric tests. Intraspecialty variation in orthopedic surgery was assessed between the bottom and top 10th percentiles in procedure categories. Case logs for 9605 general surgery residents and 5911 orthopedic surgery residents were analyzed. Orthopedic surgery residents performed a greater number of hand surgery cases than general surgery residents ( P < .001). Mean total hand experience ranged from 2.5 ± 4 to 2.8 ± 5 procedures for general surgery residents with no reported cases of soft tissue repairs, vascular repairs, and replants. Significant intraspecialty variation existed in orthopedic surgery for all hand procedure categories (range, 3.3-15.0). As the model for hand surgery training evolves, general surgeons may represent an underutilized talent pool to meet the critical demand for hand surgeon specialists. Future research is needed to determine acceptable levels of training variability in hand surgery.

  4. A comparative direct cost analysis of pediatric urologic robot-assisted laparoscopic surgery versus open surgery: could robot-assisted surgery be less expensive?

    PubMed

    Rowe, Courtney K; Pierce, Michael W; Tecci, Katherine C; Houck, Constance S; Mandell, James; Retik, Alan B; Nguyen, Hiep T

    2012-07-01

    Cost in healthcare is an increasing and justifiable concern that impacts decisions about the introduction of new devices such as the da Vinci(®) surgical robot. Because equipment expenses represent only a portion of overall medical costs, we set out to make more specific cost comparisons between open and robot-assisted laparoscopic surgery. We performed a retrospective, observational, matched cohort study of 146 pediatric patients undergoing either open or robot-assisted laparoscopic urologic surgery from October 2004 to September 2009 at a single institution. Patients were matched based on surgery type, age, and fiscal year. Direct internal costs from the institution were used to compare the two surgery types across several procedures. Robot-assisted surgery direct costs were 11.9% (P=0.03) lower than open surgery. This cost difference was primarily because of the difference in hospital length of stay between patients undergoing open vs robot-assisted surgery (3.8 vs 1.6 days, P<0.001). Maintenance fees and equipment expenses were the primary contributors to robotic surgery costs, while open surgery costs were affected most by room and board expenses. When estimates of the indirect costs of robot purchase and maintenance were included, open surgery had a lower total cost. There were no differences in follow-up times or complication rates. Direct costs for robot-assisted surgery were significantly lower than equivalent open surgery. Factors reducing robot-assisted surgery costs included: A consistent and trained robotic surgery team, an extensive history of performing urologic robotic surgery, selection of patients for robotic surgery who otherwise would have had longer hospital stays after open surgery, and selection of procedures without a laparoscopic alternative. The high indirect costs of robot purchase and maintenance remain major factors, but could be overcome by high surgical volume and reduced prices as competitors enter the market.

  5. Plastic surgery in the press.

    PubMed

    Reid, A J; Malone, P S C

    2008-08-01

    The media play a vital role in public education. The predominant image they portray of plastic and reconstructive surgery is that of cosmetic surgery, whilst the specialty's true scope is often misrepresented. The aim was to evaluate portrayal of plastic surgery in the national newspapers. LexisNexis Professional search engine was used to retrieve articles from all UK newspapers published in 2006 that contained the term 'plastic surgery' and each article was analysed. Of 1191 articles, 89% used the term 'plastic surgery' in the context of cosmetic surgery and only 10% referred to reconstructive work. There were 197 feature articles on cosmetic surgery and 52% of them included a quote from the medical profession. If the quoted doctor was on the UK General Medical Council (GMC) specialist register for plastic surgery, it was significantly more likely that a potential problem or complication associated with cosmetic surgery would be mentioned (p= 0.015). The vast majority of newspaper articles refer only to the cosmetic component of plastic surgery. When quoted, doctors on the GMC specialist register for plastic surgery provide a more balanced view of cosmetic surgery. Further initiative is needed to portray the full scope of plastic and reconstructive surgery to the general public.

  6. Risk factors for incidental durotomy during lumbar surgery: a retrospective study by multivariate analysis.

    PubMed

    Chen, Zhixiang; Shao, Peng; Sun, Qizhao; Zhao, Dong

    2015-03-01

    The purpose of the present study was to use a prospectively collected data to evaluate the rate of incidental durotomy (ID) during lumbar surgery and determine the associated risk factors by using univariate and multivariate analysis. We retrospectively reviewed 2184 patients who underwent lumbar surgery from January 1, 2009 to December 31, 2011 at a single hospital. Patients with ID (n=97) were compared with the patients without ID (n=2019). The influences of several potential risk factors that might affect the occurrence of ID were assessed using univariate and multivariate analyses. The overall incidence of ID was 4.62%. Univariate analysis demonstrated that older age, diabetes, lumbar central stenosis, posterior approach, revision surgery, prior lumber surgery and minimal invasive surgery are risk factors for ID during lumbar surgery. However, multivariate analysis identified older age, prior lumber surgery, revision surgery, and minimally invasive surgery as independent risk factors. Older age, prior lumber surgery, revision surgery, and minimal invasive surgery were independent risk factors for ID during lumbar surgery. These findings may guide clinicians making future surgical decisions regarding ID and aid in the patient counseling process to alleviate risks and complications. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Unique Assessment of Hand Surgery Knowledge by Specialty.

    PubMed

    Silvestre, Jason; Lin, Ines C; Chang, Benjamin; Levin, L Scott

    2016-03-01

    Orthopedic and plastic surgery residents receive unique training yet often compete for similar hand surgery fellowships. This study compared didactic hand surgery training during orthopedic and plastic surgery residency. The Plastic Surgery In-Service Training Exam and Orthopaedic In-Training Examination were analyzed for hand content for the years 2009 to 2013. Topics were categorized with the content outline for the Surgery of the Hand Examination. Differences were elucidated by means of Fisher's exact test. Relative to the Orthopaedic In-Training Examination, the Plastic Surgery In-Service Training Exam had greater hand representation (20.3 percent versus 8.1 percent; p < 0.001) with more annual hand questions (40 ± 3 versus 24 ± 2; p < 0.001). The Plastic Surgery Exam questions had more words, were less often level I-recall type, and were less often image-based. The questions focused more on finger and hand/palm anatomy, whereas the Orthopaedic examination was more wrist-focused. The Plastic Surgery Exam emphasized wound management and muscle/tendon injuries, but underemphasized fractures/dislocations. References differed, but Journal of Hand Surgery (American Volume) and Green's Operative Hand Surgery were common on both examinations. The Plastic Surgery Exam had a greater publication lag for journal references (10.7 ± 0.5 years versus 9.0 ± 0.6; p = 0.035). Differences in didactic hand surgery training are elucidated for plastic surgery and orthopedic residents. Deficiencies in the Plastic Surgery In-Service Training Exam hand curriculum relative to the Orthopaedic In-Training Examination may underprepare plastic surgeons for the Surgery of the Hand Examination. These data may assist future modifications to hand surgery training in the United States.

  8. Lung surgery

    MedlinePlus

    ... Lung tissue removal; Pneumonectomy; Lobectomy; Lung biopsy; Thoracoscopy; Video-assisted thoracoscopic surgery; VATS ... do surgery on your lungs are thoracotomy and video-assisted thoracoscopic surgery (VATS). Robotic surgery may also ...

  9. Resident Exposure to Peripheral Nerve Surgical Procedures During Residency Training

    PubMed Central

    Gil, Joseph A.; Daniels, Alan H.; Akelman, Edward

    2016-01-01

    Background Variability in case exposures has been identified for orthopaedic surgery residents. It is not known if this variability exists for peripheral nerve procedures. Objective The objective of this study was to assess ACGME case log data for graduating orthopaedic surgery, plastic surgery, general surgery, and neurological surgery residents for peripheral nerve surgical procedures and to evaluate intraspecialty and interspecialty variability in case volume. Methods Surgical case logs from 2009 to 2014 for the 4 specialties were compared for peripheral nerve surgery experience. Peripheral nerve case volume between specialties was performed utilizing a paired t test, 95% confidence intervals were calculated, and linear regression was calculated to assess the trends. Results The average number of peripheral nerve procedures performed per graduating resident was 54.2 for orthopaedic surgery residents, 62.8 for independent plastic surgery residents, 84.6 for integrated plastic surgery residents, 22.4 for neurological surgery residents, and 0.4 for surgery residents. Intraspecialty comparison of the 10th and 90th percentile peripheral nerve case volume in 2012 revealed remarkable variability in training. There was a 3.9-fold difference within orthopaedic surgery, a 5.0-fold difference within independent plastic surgery residents, an 8.8-fold difference for residents from integrated plastic surgery programs, and a 7.0-fold difference within the neurological surgery group. Conclusions There is interspecialty and intraspecialty variability in peripheral nerve surgery volume for orthopaedic, plastic, neurological, and general surgery residents. Caseload is not the sole determinant of training quality as mentorship, didactics, case breadth, and complexity play an important role in training. PMID:27168883

  10. What Is Heart Surgery?

    MedlinePlus

    ... heart surgery that is becoming more common is robotic-assisted surgery. For this surgery, a surgeon uses a computer ... surgeon always is in total control of the robotic arms; they don't move on their own. Who Needs Heart Surgery? Heart surgery is used to treat many heart ...

  11. European endocrine surgery in the 150-year history of Langenbeck's Archives of Surgery.

    PubMed

    Dralle, Henning; Machens, A

    2010-04-01

    Founded in 1861 as a German language scientific forum of exchange for European surgeons, Langenbeck's Archives of Surgery quickly advanced to become the premier journal of thyroid surgery before World War I, serving as a point of crystallization for the emerging discipline of endocrine surgery. During the interwar period and, in particular, in the first decades after World War II, Langenbeck's Archives of Surgery lost its dominant position as an international and European medium of publication of top quality articles in the area of endocrine surgery. Nevertheless, the journal remained the chief publication organ of German language articles in the field of endocrine surgery. After a series of key events, Langenbeck's Archives of Surgery managed to reclaim its former position as the leading European journal of endocrine surgery: (1) the formation of endocrine surgery in the early 1980s as a subdiscipline of general and visceral surgery; (2) the change of the language of publication from German to English in 1998; and (3) the journal's appointment in 2004 as the official organ of publication of the European Society of Endocrine Surgeons. All in all, the 150-year publication record of Langenbeck's Archives of Surgery closely reflects the history of European Endocrine Surgery. Following the path of seminal articles from Billroth, Kocher, and many other surgical luminaries published in the journal more than 100 years ago, Langenbeck's Archives of Surgery today stands out as the principal European journal in the field of endocrine surgery.

  12. Simultaneous Versus Sequential Ptosis and Strabismus Surgery in Children.

    PubMed

    Revere, Karen E; Binenbaum, Gil; Li, Jonathan; Mills, Monte D; Katowitz, William R; Katowitz, James A

    The authors sought to compare the clinical outcomes of simultaneous versus sequential ptosis and strabismus surgery in children. Retrospective, single-center cohort study of children requiring both ptosis and strabismus surgery on the same eye. Simultaneous surgeries were performed during a single anesthetic event; sequential surgeries were performed at least 7 weeks apart. Outcomes were ptosis surgery success (margin reflex distance 1 ≥ 2 mm, good eyelid contour, and good eyelid crease); strabismus surgery success (ocular alignment within 10 prism diopters of orthophoria and/or improved head position); surgical complications; and reoperations. Fifty-six children were studied, 38 had simultaneous surgery and 18 sequential. Strabismus surgery was performed first in 38/38 simultaneous and 6/18 sequential cases. Mean age at first surgery was 64 months, with mean follow up 27 months. A total of 75% of children had congenital ptosis; 64% had comitant strabismus. A majority of ptosis surgeries were frontalis sling (59%) or Fasanella-Servat (30%) procedures. There were no significant differences between simultaneous and sequential groups with regards to surgical success rates, complications, or reoperations (all p > 0.28). In the first comparative study of simultaneous versus sequential ptosis and strabismus surgery, no advantage for sequential surgery was seen. Despite a theoretical risk of postoperative eyelid malposition or complications when surgeries were performed in a combined manner, the rate of such outcomes was not increased with simultaneous surgeries. Performing ptosis and strabismus surgery together appears to be clinically effective and safe, and reduces anesthesia exposure during childhood.

  13. Orthopaedic jack for scoliosis surgery purposes: Concept and design

    NASA Astrophysics Data System (ADS)

    Supriadi, Sugeng; Radhana, Rakha M.; Hidayanto, Taufik Eko; Whulanza, Yudan; Ali, Notario, Nanda; Rahyussalim

    2017-02-01

    Scoliosis surgery is one of the most difficult orthopedic surgery that have been committed today as the failure rate of orthopedic surgery for adult patients is 15%. Aside from the long duration of surgery, this surgical failure is caused by failure in biomedical instrumentation. Furthermore, this kind of failure is causing inefficiency of the surgery. With current known orthopedic surgery method, three surgeons are needed in a single orthopedic surgery. In fact, a single surgery can take up to 8 hours to be done, which increases the risk of surgical failure. Based on this problem, authors hope that our orthopedic jacks could solve the problem.

  14. Heart bypass surgery

    MedlinePlus

    Off-pump coronary artery bypass; OPCAB; Beating heart surgery; Bypass surgery - heart; CABG; Coronary artery bypass graft; Coronary artery bypass surgery; Coronary bypass surgery; Coronary artery disease - CABG; CAD - CABG; Angina - ...

  15. Does procedure profitability impact whether an outpatient surgery is performed at an ambulatory surgery center or hospital?

    PubMed

    Plotzke, Michael Robert; Courtemanche, Charles

    2011-07-01

    Ambulatory surgery centers (ASCs) are small (typically physician owned) healthcare facilities that specialize in performing outpatient surgeries and therefore compete against hospitals for patients. Physicians who own ASCs could treat their most profitable patients at their ASCs and less profitable patients at hospitals. This paper asks if the profitability of an outpatient surgery impacts where a physician performs the surgery. Using a sample of Medicare patients from the National Survey of Ambulatory Surgery, we find that higher profit surgeries do have a higher probability of being performed at an ASC compared to a hospital. After controlling for surgery type, a 10% increase in a surgery's profitability is associated with a 1.2 to 1.4 percentage point increase in the probability the surgery is performed at an ASC. Copyright © 2010 John Wiley & Sons, Ltd.

  16. Avoiding endotracheal intubation of neonates undergoing laser surgery for retinopathy of prematurity.

    PubMed

    Woodhead, D D; Lambert, D K; Molloy, D A; Schmutz, N; Righter, E; Baer, V L; Christensen, R D

    2007-04-01

    Respiratory support of neonates during and following laser surgery for retinopathy of prematurity (ROP) is commonly accomplished using endotracheal intubation and mechanical ventilation. However, most patients undergoing ROP surgery have been weaned off mechanical ventilation days or weeks before the surgery. When they are electively re-intubated for ROP surgery, it can be difficult to extubate them postoperatively. One of the three level III neonatal intensive care units (NICUs) in the Intermountain Healthcare system initiated a program of using nasopharyngeal prongs, rather than endotracheal intubation, for respiratory support during ROP surgery. We performed an historic cohort analysis of all neonates undergoing ROP surgery during their NICU stay at the three level III NICU's between 1 January 2002 and 31 March 2006. Data collected included birth weight, gestational age at delivery and corrected gestational age at ROP surgery, whether or not they were intubated in the days immediately preceding the ROP surgery, whether or not they were electively intubated for the ROP surgery, the respiratory modality used during and the 3 days following ROP surgery, and all blood gas determinations and respiratory charges during this period. Fifty-four patients underwent ROP surgery during this period. All 23 from NICUs 'A' and 'B' had endotracheal intubation for surgery, while in NICU 'C' 24 were managed using nasopharyngeal prongs. The birth weights of those intubated for surgery (661+/-180 g, mean+/-s.d.) were similar to those not intubated (732+/-180 g). Similarly, the gestational age at birth did not differ between those intubated for surgery (25.2+/-1.3 week) and those not (25.6+/-2.1 week). The day following surgery, 77% (23/30) of those who had been intubated for surgery remained intubated and on mechanical ventilation, whereas only one (4%) of those not intubated for surgery was intubated in the postoperative period (P<0.001). On day 3 following surgery, 50% (15/30) of those intubated for surgery remained intubated and on mechanical ventilation, whereas none of those not intubated for surgery were intubated (P<0.001). Management with nasopharyngeal prongs did not result in higher PCO(2)s, or lower pH values, during or after surgery. Respiratory charges for the 3 days following surgery were 1762+/-678 dollars (mean+/-s.d.)/patient among those intubated versus 357+/-352 dollars/patient for those managed with nasopharyngeal prongs (P<0.001). Neonates undergoing laser surgery for ROP can often be supported intraoperatively and postoperatively using nasopharyngeal prongs, thus avoiding the need for endotracheal intubation.

  17. Tennis elbow surgery - discharge

    MedlinePlus

    Lateral epicondylitis surgery - discharge; Lateral tendinosis surgery - discharge; Lateral tennis elbow surgery - discharge ... Soon after surgery, severe pain will decrease, but you may have mild soreness for 3 to 6 months.

  18. Variability in spine surgery procedures performed during orthopaedic and neurological surgery residency training: an analysis of ACGME case log data.

    PubMed

    Daniels, Alan H; Ames, Christopher P; Smith, Justin S; Hart, Robert A

    2014-12-03

    Current spine surgeon training in the United States consists of either an orthopaedic or neurological surgery residency, followed by an optional spine surgery fellowship. Resident spine surgery procedure volume may vary between and within specialties. The Accreditation Council for Graduate Medical Education surgical case logs for graduating orthopaedic surgery and neurosurgery residents from 2009 to 2012 were examined and were compared for spine surgery resident experience. The average number of reported spine surgery procedures performed during residency was 160.2 spine surgery procedures performed by orthopaedic surgery residents and 375.0 procedures performed by neurosurgery residents; the mean difference of 214.8 procedures (95% confidence interval, 196.3 to 231.7 procedures) was significant (p = 0.002). From 2009 to 2012, the average total spinal surgery procedures logged by orthopaedic surgery residents increased 24.3% from 141.1 to 175.4 procedures, and those logged by neurosurgery residents increased 6.5% from 367.9 to 391.8 procedures. There was a significant difference (p < 0.002) in the average number of spinal deformity procedures between graduating orthopaedic surgery residents (9.5 procedures) and graduating neurosurgery residents (2.0 procedures). There was substantial variability in spine surgery exposure within both specialties; when comparing the top 10% and bottom 10% of 2012 graduates for spinal instrumentation or arthrodesis procedures, there was a 13.1-fold difference for orthopaedic surgery residents and an 8.3-fold difference for neurosurgery residents. Spine surgery procedure volumes in orthopaedic and neurosurgery residency training programs vary greatly both within and between specialties. Although orthopaedic surgery residents had an increase in the number of spine procedures that they performed from 2009 to 2012, they averaged less than half of the number of spine procedures performed by neurological surgery residents. However, orthopaedic surgery residents appear to have greater exposure to spinal deformity than neurosurgery residents. Furthermore, orthopaedic spine fellowship training provides additional spine surgery case exposure of approximately 300 to 500 procedures; thus, before entering independent practice, when compared with neurosurgery residents, most orthopaedic spine surgeons complete as many spinal procedures or more. Although case volume is not the sole determinant of surgical skills or clinical decision making, variability in spine surgery procedure volume does exist among residency programs in the United States. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.

  19. [The comparative analysis of clinical symptomatology before and after the operation of otosclerosis].

    PubMed

    Terzić, Negra; Zivić, Ljubica

    2009-01-01

    Otosclerosis is a progressive osteodystrophic disease of the osseous capsule of the labyrinth which leads to the fixation of the stapes and partial deafness. The progressive hearing loss followed by ear tingling--tinitus and vertigo is of great importance for this disease. The aim of the work was to determine the changes of clinical symptomatology before and after the operative treatment of otoscleoris. The study included 32 subjects between 25 and 60 years of age affected by otosclerosis who had undergone surgical treatment at the VMA (Military Medical Academy) Clinic, Department of Otolaryngology in Belgrade. Besides the clinical examination and detailed case history, audiometry and tympanometry examinations were performed. During the postoperative period the clinical symptomatology was evaluated and audiometry examinations were performed in order to determine the effect of the surgical intervention. Of the total number of 32 subjects, partial deafness was present in all of them before the operation, whereas tinitus, vertiginous disturbances and otalgia were found in a certain number of the subjects. During the postoperative period a partial recovery was found in a larger number of the subjects in relation to the total hearing recovery. During the postoperative period tinitus of lower intensity was found in a greater number of the subjects, whereas the number of those without tinitus was smaller. The problem of vertiginous disturbances as well as otalgia were not found during the postoperative period. By following the changes of the clinical symptomatology we came to the conclusion that surgical treatment of otosclerosis results in the reduction and disappearance of subjective disturbances, tinitus, vertigo and otalgia and leads to the partial or complete hearing recovery.

  20. Human cochlear hydrodynamics: A high-resolution μCT-based finite element study.

    PubMed

    De Paolis, Annalisa; Watanabe, Hirobumi; Nelson, Jeremy T; Bikson, Marom; Packer, Mark; Cardoso, Luis

    2017-01-04

    Measurements of perilymph hydrodynamics in the human cochlea are scarce, being mostly limited to the fluid pressure at the basal or apical turn of the scalae vestibuli and tympani. Indeed, measurements of fluid pressure or volumetric flow rate have only been reported in animal models. In this study we imaged the human ear at 6.7 and 3-µm resolution using µCT scanning to produce highly accurate 3D models of the entire ear and particularly the cochlea scalae. We used a contrast agent to better distinguish soft from hard tissues, including the auditory canal, tympanic membrane, malleus, incus, stapes, ligaments, oval and round window, scalae vestibule and tympani. Using a Computational Fluid Dynamics (CFD) approach and this anatomically correct 3D model of the human cochlea, we examined the pressure and perilymph flow velocity as a function of location, time and frequency within the auditory range. Perimeter, surface, hydraulic diameter, Womersley and Reynolds numbers were computed every 45° of rotation around the central axis of the cochlear spiral. CFD results showed both spatial and temporal pressure gradients along the cochlea. Small Reynolds number and large Womersley values indicate that the perilymph fluid flow at auditory frequencies is laminar and its velocity profile is plug-like. The pressure was found 102-106° out of phase with the fluid flow velocity at the scalae vestibule and tympani, respectively. The average flow velocity was found in the sub-µm/s to nm/s range at 20-100Hz, and below the nm/s range at 1-20kHz. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Model-oriented review and multi-body simulation of the ossicular chain of the human middle ear.

    PubMed

    Volandri, G; Di Puccio, F; Forte, P; Manetti, S

    2012-11-01

    The ossicular chain of the human middle ear has a key role in sound conduction since it transfers vibrations from the tympanic membrane to the cochlea, connecting the outer and the inner part of the hearing organ. This study reports firstly a description of the main anatomical features of the middle ear to introduce a detailed survey of its biomechanics, focused on model development, with a collection of geometric, inertial and mechanical/material parameters. The joint issues are particularly discussed from the perspective of developing a model of the middle ear both explanatory and predictive. Such a survey underlines the remarkable dispersion of data, due also to the lack of a standardization of the experimental techniques and conditions. Subsequently, a 3D multi-body model of the ossicular chain and other structures of the middle ear is described. Such an approach is justified as the ossicles were proven to behave as rigid bodies in the human hearing range and was preferred to the more widely used finite element one as it simplifies the model development and improves joint modeling. The displacement of the umbo (a reference point of the tympanic membrane) in the 0.3-6kHz frequency range was defined as input of the model, while the stapes footplate displacement as output. A parameter identification procedure was used to find parameter values for reproducing experimental and numerical reference curves taken from the literature. This simple model might represent a valid alternative to more complex models and might provide a useful tool to simulate pathological/post-surgical/post-traumatic conditions and evaluate ossicular replacement prostheses. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

  2. Multicentre investigation on electrically evoked compound action potential and stapedius reflex: how do these objective measures relate to implant programming parameters?

    PubMed

    Van Den Abbeele, Thierry; Noël-Petroff, Nathalie; Akin, Istemihan; Caner, Gül; Olgun, Levent; Guiraud, Jeanne; Truy, Eric; Attias, Josef; Raveh, Eyal; Belgin, Erol; Sennaroglu, Gonca; Basta, Dietmar; Ernst, Arneborg; Martini, Alessandro; Rosignoli, Monica; Levi, Haya; Elidan, Joseph; Benghalem, Abdelhamid; Amstutz-Montadert, Isabelle; Lerosey, Yannick; De Vel, Eddy; Dhooge, Ingeborg; Hildesheimer, Minka; Kronenberg, Jona; Arnold, Laure

    2012-02-01

    The aims of this study were to collect data on electrically evoked compound action potential (eCAP) and electrically evoked stapedius reflex thresholds (eSRT) in HiResolution(TM) cochlear implant (CI) users, and to explore the relationships between these objective measures and behavioural measures of comfort levels (M-levels). A prospective study on newly implanted subjects was designed. The eCAP was measured intra-operatively and at first fitting through neural response imaging (NRI), using the SoundWave(TM) fitting software. The eSRT was measured intra-operatively by visual monitoring of the stapes, using both single-electrode stimulation and speech bursts (four electrodes stimulated at the same time). Measures of M-levels were performed according to standard clinical practice and collected at first fitting, 3 and 6 months of CI use. One hundred seventeen subjects from 14 centres, all implanted unilaterally with a HiResolution CII Bionic Ear(®) or HiRes 90K(®), were included in the study. Speech burst stimulation elicited a significantly higher eSRT success rate than single-electrode stimulation, 84 vs. 64% respectively. The NRI success rate was 81% intra-operatively, significantly increasing to 96% after 6 months. Fitting guidelines were defined on the basis of a single NRI measurement. Correlations, analysis of variance, and multiple regression analysis were applied to generate a predictive model for the M-levels. Useful insights were produced into the behaviour of objective measures according to time, electrode location, and fitting parameters. They may usefully assist in programming the CI when no reliable feedback is obtained through standard behavioural procedures.

  3. Cataract Surgery

    MedlinePlus

    ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Academy Publications EyeNet Ophthalmology ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Find an Ophthalmologist Advanced ...

  4. Incidence of Postoperative Deep Venous Thrombosis Is Higher among Cardiac and Vascular Surgery Patients as Compared with General Surgery Patients.

    PubMed

    Aziz, Faisal; Patel, Mayank; Ortenzi, Gail; Reed, Amy B

    2015-01-01

    Unlike general surgery patients, most of vascular and cardiac surgery patients receive therapeutic anticoagulation during operations. The purpose of this study was to report the incidence of deep venous thrombosis (DVT) among cardiac and vascular surgery patients, compared with general surgery. The American College of Surgeons National Surgical Quality Improvement Program database was queried for all patients who underwent surgical procedures from 2005 to 2010. Patients who developed DVT within 30 days of an operation were identified. The incidence of DVT was compared among vascular, general, and cardiac surgery patients. Risk factors for developing postoperative DVT were identified and compared among these patients. Of total 2,669,772 patients underwent surgical operations in the period between 2005 and 2010. Of all the patients, 18,670 patients (0.69%) developed DVT. The incidence of DVT among different surgical specialties was cardiac surgery (2%), vascular surgery (0.99%), and general surgery (0.66%). The odds ratio for developing DVT was 1.5 for vascular surgery patients and 3 for cardiac surgery patients, when compared with general surgery patients (P < 0.001). The odds ratio for developing DVT after cardiac surgery was 2, when compared with vascular surgery (P < 0.001). The incidence of DVT is higher among vascular and cardiac surgery patients as compared with that of general surgery patients. Intraoperative anticoagulation does not prevent the occurrence of DVT in the postoperative period. These patients should receive DVT prophylaxis in the perioperative period, similar to other surgical patients according to evidence-based guidelines. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. The role of laparoscopic surgery for ulcerative colitis: systematic review with meta-analysis.

    PubMed

    Wu, Xiao-Jian; He, Xiao-Sheng; Zhou, Xu-Yu; Ke, Jia; Lan, Ping

    2010-08-01

    Crohn's disease is established in laparoscopic surgery due to partial bowel dissection and low postoperative complication rate. However, laparoscopic surgery for ulcerative colitis remains further discussed even if the trend of minimally invasive technique exists. This study is to figure out how laparoscopic surgery works for ulcerative colitis. Sixteen controlled trials were identified through the search strategy mentioned below. There was only one prospective randomized study among the studies selected. A meta-analysis pooled the outcome effects of laparoscopic surgery and open surgery was performed. Fixed effect model or random effect model was respectively used depending on the heterogeneity test of trials. Postoperative fasting time and postoperative hospital stay were shorter in laparoscopic surgery for ulcerative colitis (-1.37 [-2.15, -0.58], -3.22 [-4.20, -2.24], respectively, P < 0.05). Overall complication rate was higher in open surgery, compared with laparoscopic surgery (54.8% versus 39.3%, P = 0.004). However, duration of laparoscopic surgery for ulcerative colitis was extended compared with open surgery (weighted mean difference 69.29 min, P = 0.04). As to recovery of bowel function, peritoneal abscess, anastomotic leakage, postoperative bowel obstruction, wound infection, blood loss, and mortality, laparoscopic surgery did not show any superiority over open surgery. Re-operation rate was almost even (5.2% versus 7.3%). The whole conversion to open surgery was 4.2%. Laparoscopic surgery for ulcerative colitis was at least as safe as open surgery, even better in postoperative fasting time, postoperative hospital stay, and overall complication rate. However, clinical value of laparoscopic surgery for ulcerative colitis needed further evaluation with more well-designed and long-term follow-up studies.

  6. Receptivity to Bariatric Surgery in Qualified Patients

    PubMed Central

    Fung, Michael; Wharton, Sean; Macpherson, Alison

    2016-01-01

    Objectives. Bariatric surgery has been shown to be an effective intervention for weight loss and diabetes management. Despite this, many patients qualified for bariatric surgery are not interested in undergoing the procedure. The objective of this study is to determine the factors influencing receptivity to bariatric surgery among those who qualify for the procedure. Methods. Patients attending a publicly funded weight management clinic who qualified for bariatric surgery were asked to complete an elective questionnaire between February 2013 and April 2014. Results. A total of 371 patients (72% female) completed the questionnaire. Only 87 of 371 (23%) participants were interested in bariatric surgery. Individuals interested in bariatric surgery had a higher BMI (48.0 versus 46.2 kg/m2, P = 0.03) and believed that they would lose more weight with surgery (51 versus 44 kg, P = 0.0069). Those who scored highly on past weight loss success and financial concerns were less likely to be interested in bariatric surgery, whereas those who scored highly on high receptivity to surgery and positive social support were more likely to be interested in bariatric surgery. Conclusion. Although participants overestimated the effect of bariatric surgery on weight loss, most were still not interested in bariatric surgery. PMID:27516900

  7. The day of your surgery - adult

    MedlinePlus

    Same-day surgery - adult; Ambulatory surgery - adult; Surgical procedure - adult; Preoperative care - day of surgery ... meet with them at an appointment before the day of surgery or on the same day of ...

  8. Outcome of appendicectomy in children performed in paediatric surgery units compared with general surgery units.

    PubMed

    Tiboni, S; Bhangu, A; Hall, N J

    2014-05-01

    Appendicectomy for acute appendicitis in children may be performed in specialist centres by paediatric surgeons or in general surgery units. Service provision and outcome of appendicectomy in children may differ between such units. This multicentre observational study included all children (aged less than 16 years) who had an appendicectomy at either a paediatric surgery unit or general surgery unit. The primary outcome was normal appendicectomy rate (NAR). Secondary outcomes included 30-day adverse events, use of ultrasound imaging and laparoscopy, and consultant involvement in procedures. Appendicectomies performed in 19 paediatric surgery units (242 children) and 54 general surgery units (461 children) were included. Children treated in paediatric surgery units were younger and more likely to have a preoperative ultrasound examination, a laparoscopic procedure, a consultant present at the procedure, and histologically advanced appendicitis than children treated in general surgery units. The unadjusted NAR was significantly lower in paediatric surgery units (odds ratio (OR) 0.37, 95 per cent confidence interval 0.23 to 0.59; P < 0.001), and the difference persisted after adjusting for age, sex and use of preoperative ultrasound imaging (OR 0.34, 0.21 to 0.57; P < 0.001). Female sex and preoperative ultrasonography, but not age, were significantly associated with normal appendicectomy in general surgery units but not in paediatric surgery units in this adjusted model. The unadjusted 30-day adverse event rate was higher in paediatric surgery units than in general surgery units (OR 1.90, 1.18 to 3.06; P = 0.011). When adjusted for case mix and consultant presence at surgery, no statistically significant relationship between centre type and 30-day adverse event rate existed (OR 1.59, 0.93 to 2.73; P = 0.091). The NAR in general surgery units was over twice that in paediatric surgery units. Despite a more severe case mix, paediatric surgery units had a similar 30-day adverse event rate to general surgery units. Service provision differs between paediatric and general surgery units. © 2014 BJS Society Ltd. Published by John Wiley & Sons Ltd.

  9. Survey of minimally invasive general surgery fellows training in robotic surgery.

    PubMed

    Shaligram, Abhijit; Meyer, Avishai; Simorov, Anton; Pallati, Pradeep; Oleynikov, Dmitry

    2013-06-01

    Minimally invasive surgery fellowships offer experience in robotic surgery, the nature of which is poorly defined. The objective of this survey was to determine the current status and opportunities for robotic surgery training available to fellows training in the United States and Canada. Sixty-five minimally invasive surgery fellows, attending a fundamentals of fellowship conference, were asked to complete a questionnaire regarding their demographics and experiences with robotic surgery and training. Fifty-one of the surveyed fellows completed the questionnaire (83 % response). Seventy-two percent of respondents had staff surgeons trained in performing robotic procedures, with 55 % of respondents having general surgery procedures performed robotically at their institution. Just over half (53 %) had access to a simulation facility for robotic training. Thirty-three percent offered mechanisms for certification and 11 % offered fellowships in robotic surgery. One-third of the minimally invasive surgery fellows felt they had been trained in robotic surgery and would consider making it part of their practice after fellowship. However, most (80 %) had no plans to pursue robotic surgery fellowships. Although a large group (63 %) felt optimistic about the future of robotic surgery, most respondents (72.5 %) felt their current experience with robotic surgery training was poor or below average. There is wide variation in exposure to and training in robotic surgery in minimally invasive surgery fellowship programs in the United States and Canada. Although a third of trainees felt adequately trained for performing robotic procedures, most fellows felt that their current experience with training was not adequate.

  10. Adjusting to Random Demands of Patient Care: A Predictive Model for Nursing Staff Scheduling at Naval Medical Center San Diego

    DTIC Science & Technology

    2008-09-01

    rich mix of medical services that range from simple ambulatory visits to plastic surgery , neuro- surgery , general surgery , bariatric , ophthalmology...CENTER SAN DIEGO NMCSD is a 266-bed tertiary care facility providing patient services ranging from same day surgery to brain surgery . The hospital...orthopedics, cardiology, thoracic surgery , vascular surgery , transient ischemic attack/cerebro vascular accident (TIA/CVA), OB/GYN, urology, non

  11. Bariatric Surgery

    MedlinePlus

    ... Weight Loss Featured Resource Find an Endocrinologist Search Bariatric Surgery Download PDFs English Espanol Editors Durga Singer, MD, ... for Metabolic and Bariatric Surgery MedlinePlus What is bariatric surgery? Bariatric surgery helps people who are very obese ...

  12. Cosmetic outcomes of laparoendoscopic single-site hysterectomy compared with multi-port surgery: randomized controlled trial.

    PubMed

    Song, Taejong; Cho, Juhee; Kim, Tae-Joong; Kim, Im-Ryung; Hahm, Tae Soo; Kim, Byoung-Gie; Bae, Duk-Soo

    2013-01-01

    To compare cosmetic satisfaction with laparoendoscopic single-site surgery (LESS) compared with multi-port surgery. Randomized controlled trial (Canadian Task Force classification I). University hospital. Twenty women who underwent laparoscopically-assisted vaginal hysterectomy (LAVH) via LESS or multi-port surgery. Laparoendoscopic single-site surgery or multi-port surgery. Cosmetic satisfaction was assessed using the Body Image Questionnaire at baseline and at 1, 4, and 24 weeks after surgery. Of the 20 LESS procedures, 1 was converted to multi-port surgery because of severe adhesions, and 1 woman assigned to undergo multi-port surgery was lost to follow-up. The 2 surgery groups did not differ in clinical demographic data and surgical results or postoperative pain scores at 12, 24, and 36 hours. Compared with the multi-port group, the LESS group reported significantly higher cosmetic satisfaction at 1, 4, and 24 weeks after surgery (p < .01). Compared with multi-port surgery, LESS is not only a feasible approach with comparable operative outcomes but also has an advantage insofar as cosmetic outcome. Copyright © 2013 AAGL. Published by Elsevier Inc. All rights reserved.

  13. [Minimally invasive surgery and robotic surgery: surgery 4.0?].

    PubMed

    Feußner, H; Wilhelm, D

    2016-03-01

    Surgery can only maintain its role in a highly competitive environment if results are continuously improved, accompanied by further reduction of the interventional trauma for patients and with justifiable costs. Significant impulse to achieve this goal was expected from minimally invasive surgery and, in particular, robotic surgery; however, a real breakthrough has not yet been achieved. Accordingly, the new strategic approach of cognitive surgery is required to optimize the provision of surgical treatment. A full scale integration of all modules utilized in the operating room (OR) into a comprehensive network and the development of systems with technical cognition are needed to upgrade the current technical environment passively controlled by the surgeon into an active collaborative support system (surgery 4.0). Only then can the true potential of minimally invasive surgery and robotic surgery be exploited.

  14. Efficacy of tension-free vaginal tape compared with transobturator tape in the treatment of stress urinary incontinence in women: analysis of learning curve, perioperative changes of voiding function

    PubMed Central

    2011-01-01

    Background In this study, by comparing TVT surgery and TOT surgery for stress urinary incontinence in women, the characteristics and learning curves of both operative methods were studied. Methods A total of 83 women with stress urinary incontinence treated with tension-free vaginal tape (TVT) (n = 38) or transobturator tape (TOT) (n = 45) at Saiseikai Central Hospital between April 2004 and September 2009 were included. We compare the outcomes and learning curves between TVT surgery and TOT surgery. In statistical analysis, Student's t test, Fisher's exact test, and Mann-Whitney's U test were used. Results The surgical durations were 37.4 ± 15.7 minutes with TVT surgery and 31.0 ± 8.3 minutes with TOT surgery. A longer period of time was required for TVT surgery (p = 0.025). The residual urine at post-operative day 1 was higher in TVT surgery (25.9 ± 44.2 ml) than in TOT surgery (10.6 ± 19.2 ml) (p = 0.0452). The surgical duration of TVT surgery was shortened after the operator had performed 15 operations (p = 0.019). Conclusions In comparison of TVT surgery and TOT surgery, the surgical duration of TVT surgery was longer and the residual urine of TVT surgery was higher at post-operative day 1. Surgical experience could shorten the duration of TVT surgery. PMID:21726448

  15. Comparison of Complications Rates in Endoscopic Surgery Performed by a Clinical Assistant vs. An Experienced Endoscopic Surgeon

    PubMed Central

    Singhi, Aditi

    2009-01-01

    Study Objectives: (a) To find out the actual incidence of complications during endoscopic surgeries. (b) Comparison of complication rate between an experienced laparoscopic surgeon (> 10 years of experience in endoscopic surgery) and a clinical assistant (> 3 years of experience in endoscopic surgery). (c) How to manage complications in endoscopic surgery. (d) Concrete suggestions to reduce the complication rate. Design: Retrospective study (Canadian Task Force classification ii-2). Setting: Tertiary gynecologic endoscopic unit. Patients: A total of 3204 cases of gynecologic endoscopic surgery out of which 2001 were laparoscopic and 1203 were hysteroscopic surgeries. Interventions: Laparoscopic and hysteroscopic gynecologic surgeries in indicated cases. Measurements and Main Results: The study was carried out between April 2003 and October 2007 at a referral center for endoscopic surgery. A total of 3204 cases of gynecologic endoscopic surgery were studied. There were five significant complications in laparoscopic surgeries and four significant complications in hysteroscopic surgeries seen in four years and six months. All the complications could be managed with no mortality. Conversion to laparotomy was needed in eight cases of laparoscopic surgeries and none in hysteroscopic surgeries. Conclusion: The risk of complication reduces with the experience in endoscopic surgery. However, the proper grooming of a novice in experienced hands, for a sufficient period of time, can minimize the complication rate in the initial learning phase. The complication may be utilized as a stepping-stone to overcome any given situation without panic, but with adequate safety. PMID:22442510

  16. Society of Thoracic Surgeons 2008 cardiac risk models predict in-hospital mortality of heart valve surgery in a Chinese population: a multicenter study.

    PubMed

    Wang, Lv; Lu, Fang-Lin; Wang, Chong; Tan, Meng-Wei; Xu, Zhi-yun

    2014-12-01

    The Society of Thoracic Surgeons 2008 cardiac surgery risk models have been developed for heart valve surgery with and without coronary artery bypass grafting. The aim of our study was to evaluate the performance of Society of Thoracic Surgeons 2008 cardiac risk models in Chinese patients undergoing single valve surgery and the predicted mortality rates of those undergoing multiple valve surgery derived from the Society of Thoracic Surgeons 2008 risk models. A total of 12,170 patients underwent heart valve surgery from January 2008 to December 2011. Combined congenital heart surgery and aortal surgery cases were excluded. A relatively small number of valve surgery combinations were excluded. The final research population included the following isolated heart valve surgery types: aortic valve replacement, mitral valve replacement, and mitral valve repair. The following combined valve surgery types were included: mitral valve replacement plus tricuspid valve repair, mitral valve replacement plus aortic valve replacement, and mitral valve replacement plus aortic valve replacement and tricuspid valve repair. Evaluation was performed by using the Hosmer-Lemeshow test and C-statistics. Data from 9846 patients were analyzed. The Society of Thoracic Surgeons 2008 cardiac risk models showed reasonable discrimination and poor calibration (C-statistic, 0.712; P = .00006 in Hosmer-Lemeshow test). Society of Thoracic Surgeons 2008 models had better discrimination (C-statistic, 0.734) and calibration (P = .5805) in patients undergoing isolated valve surgery than in patients undergoing multiple valve surgery (C-statistic, 0.694; P = .00002 in Hosmer-Lemeshow test). Estimates derived from the Society of Thoracic Surgeons 2008 models exceeded the mortality rates of multiple valve surgery (observed/expected ratios of 1.44 for multiple valve surgery and 1.17 for single valve surgery). The Society of Thoracic Surgeons 2008 cardiac surgery risk models performed well when predicting the mortality for Chinese patients undergoing valve surgery. The Society of Thoracic Surgeons 2008 models were suitable for single valve surgery in a Chinese population; estimates of mortality for multiple valve surgery derived from the Society of Thoracic Surgeons 2008 models were less accurate. Copyright © 2014 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  17. Maxillary orthognathic surgery.

    PubMed

    Bauer, Richard E; Ochs, Mark W

    2014-11-01

    Maxillary surgery to correct dentofacial deformity has been practiced for almost 100 years. Significant advances have made maxillary surgery a safe and efficient means of correcting midface deformities. Anesthetic techniques, specifically hypotensive anesthesia, have allowed for safer working conditions. Landmark studies have proven manipulation and segmentalization of the maxilla is safe and allowed this surgery to become a mainstay in corrective jaw surgery. This article provides an overview of surgical techniques and considerations as they pertain to maxillary surgery for orthognathic surgery. Segmental surgery, openbite closure, vertical excess, grafting, and a technology update are discussed. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. A new dimension in endo surgery: Micro endo surgery

    PubMed Central

    Pecora, Gabriele Edoardo; Pecora, Camilla Nicole

    2015-01-01

    There is an immense difference between tradizional Endodontic Surgery and Micro-Endo Surgery. Microsurgical techniques made possible and accessible results,that were unimaginable before. Under microscopic control,the operative techniques reached continous changes,allowing a better precision and quality standards. The dramatic evolution from Endo Surgery to Micro-Endo Surgery has enlarged the horizon of therapeutic options. Illumination and magnification through the Microscope has fundamentally and radically changed the way endo surgery can be performed. PMID:25657519

  19. Surgery on varicose veins in the early Ottoman period performed by Serefeddin Sabuncuoğlu.

    PubMed

    Darçin, Osman Tansel; Andaç, Mehmet Halit

    2003-07-01

    Serefeddin Sabuncuoğlu, a pioneer of surgery, is known to be the author of first illustrated surgery textbook, Cerrahiyyetu'l Haniyye (Imperial Surgery), which was written in Turkish in 1465 AD at the age of 80 years. The purpose of this article is to describe his contributions to varicose vein surgery. In addition to vascular surgery, Serefeddin Sabuncuoğlu was interested in a wide range of surgical specialities including thoracic surgery, general surgery, pediatric surgery, ophthalmology, orthopedic surgery, urologic surgery, and obstetrics and gynecology. His book was the first illustrated textbook of surgery in the Turkish medical literature, containing color illustrations of surgical procedures, incisions, and instruments. The book has been known of for only the past 60 years. There are 137 different medical observations and recommendations in Cerrahiyyetu'l Haniyye, along with translated passages from the works of Ebu Kasim-ul Zahravi (Albucasis), Al-Tasrif (Textbook of Surgery), including Sabuncuoğlu's additional original contributions. In chapter 90 of the book, Sabuncuoğlu describes lower extremity varices and their surgical treatment and provides a few color illustrations. Although not recognized and rewarded in his time, Serefeddin Sabuncuoğlu was a great surgeon in Turkish-Islamic medical history. This review demonstrates that his textbook, Cerrahiyyetu'l Haniyye, was the first illustrated textbook including various surgical procedures, incisions, and instruments of varicose vein surgery.

  20. Heart Valve Surgery Recovery and Follow Up

    MedlinePlus

    ... Winning Recovery Plan Post Surgery Milestones • Personal Stories Video: Preparing For Your Surgery Find helpful tips from ... how to plan and prepare for your surgery. Video: Recovering From Your Surgery Find helpful tips from ...

  1. Use of cataract surgery in urban Beijing: a post screening follow-up of the elderly with visual impairment due to age-related cataract.

    PubMed

    Ren, Xue-tao; Snellingen, Torkel; Gu, Hong; Assanangkornchai, Sawitri; Zou, Yan-hong; Chongsuvivatwong, Virasakdi; Lim, Apiradee; Jia, Wei; Liu, Xi-pu; Liu, Ning-pu

    2015-03-01

    To understand the perception for the use of cataract surgical services in a population of acceptors and non-acceptors of cataract surgery in urban Beijing. From a community-based screening program a total of 158 patients with presenting visual acuity of less than 6/18 on either eye due to age-related cataract were informed about the possibility of surgical treatment. These patients were interviewed and re-examined 36 to 46 months after initial screening. The main reasons for not accepting surgery were obtained using a questionnaire. Vision function and vision-related quality of life scores were assessed in those who received and did not receive surgery. At the follow-up examination 116 of the 158 patients were available and 36 (31.0%) had undergone cataract surgery. Cases who chose surgery had higher education level than those who did not seek surgery (OR=2.64, 95% CI: 1.08-6.63, P=0.02). There were no significant differences in vision function (P=0.11) or quality of life scores (P=0.16) between the surgery group and the non-surgery group. Main reasons for not having surgery included no perceived need (50.0%), feeling of being "too old" (19.2%), and worry about the quality of surgery (9.6%). Cost was cited by 1 (1.9%) subject as the main reason for not seeking surgery. The data suggest that in China's capital urban center for patients with moderate visual impairment there is a relative low acceptance rate of cataract surgery, mainly due to people's perception of marginal benefits of surgery. Cost is not a determining factor as barrier to undergo surgery and patients with poorer education are less likely to undertake surgery.

  2. Psychosocial predictors of quality of life and weight loss two years after bariatric surgery: Results from the Toronto Bari-PSYCH study.

    PubMed

    Sockalingam, Sanjeev; Hawa, Raed; Wnuk, Susan; Santiago, Vincent; Kowgier, Matthew; Jackson, Timothy; Okrainec, Allan; Cassin, Stephanie

    2017-07-01

    Studies exploring the impact of pre-surgery psychiatric status as a predictor of health related quality of life (QOL) after bariatric surgery have been limited to short-term follow-up and variable use of psychosocial measures. We examined the effect of pre-operative psychiatric factors on QOL and weight loss 2-years after surgery. 156 patients participated in this prospective cohort study, the Toronto Bariatric Psychosocial Cohort Study, between 2010 and 2014. Patients were assessed pre-surgery for demographic factors, weight, psychiatric diagnosis using the MINI International Neuropsychiatric Interview and symptom measures for QOL, depression and anxiety at pre-surgery and at 1 and 2years post-surgery. At 2-years post-bariatric surgery, patients experienced a significant decrease in mean weight (-48.43kg, 95% [-51.1, -45.76]) and an increase only in physical QOL (+18.91, 95% [17.01, 20.82]) scores as compared to pre-surgery. Multivariate regression analysis identified pre-surgery physical QOL score (p<0.001), younger age (p=0.005), and a history of a mood disorder as significant predictors of physical QOL. Only a history of a mood disorder (p=0.032) significantly predicted mental QOL (p=0.006). Pre-surgery weight (p<0.001) and a history of a mood disorder (p=0.047) were significant predictors of weight loss 2-years post-surgery. Bariatric surgery had a sustained impact on physical QOL but not mental QOL at 2-years post-surgery. A history of mood disorder unexpectedly increased physical QOL scores and weight loss following surgery. Further research is needed to determine if these results are due to bariatric surgery candidate selection within this program. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Pre-Surgery Psychological Factors Predict Pain, Nausea and Fatigue One Week Following Breast Cancer Surgery

    PubMed Central

    Montgomery, Guy H.; Schnur, Julie B.; Erblich, Joel; Diefenbach, Michael A.; Bovbjerg, Dana H.

    2010-01-01

    Prior to scheduled surgery, breast cancer surgical patients frequently experience high levels of distress and expect a variety of post-surgery symptoms. Previous literature has supported the view that pre-surgery distress and response expectancies are predictive of post-surgery outcomes. However, the contributions of distress and response expectancies to post-surgical side effect outcomes have rarely been examined together within the same study. Furthermore, studies on the effects of response expectancies in the surgical setting have typically focused on the immediate post-surgical setting rather than the longer term. The purpose of the present study was to test the contribution of pre-surgery distress and response expectancies to common post-surgery side effects (pain, nausea, fatigue). Female patients (n=101) undergoing breast cancer surgery were recruited to a prospective study. Results indicated that pre-surgery distress uniquely contributed to patients’ post-surgery pain severity (P<0.05) and fatigue (P<0.003) one week following surgery. Response expectancies uniquely contributed to pain severity (P<0.001), nausea (P<0.012) and fatigue (P<0.010) one week following surgery. Sobel tests indicated that response expectancies partially mediated the effects of distress on pain severity (P<0.03) and fatigue (P<0.03). Response expectancies also mediated the effects of age on pain severity, nausea and fatigue. Results highlight the contribution of pre-surgery psychological factors to post-surgery side effects, the importance of including both emotional and cognitive factors within studies as predictors of post-surgery side effects, and suggest pre-surgical clinical targets for improving patients’ postoperative experiences of side effects. PMID:20538186

  4. Cataract surgery among Medicare beneficiaries.

    PubMed

    Schein, Oliver D; Cassard, Sandra D; Tielsch, James M; Gower, Emily W

    2012-10-01

    To present descriptive epidemiology of cataract surgery among Medicare recipients in the United States. Cataract surgery performed on Medicare beneficiaries in 2003 and 2004. Medicare claims data were used to identify all cataract surgery claims for procedures performed in the United States in 2003-2004. Standard assumptions were used to limit the claims to actual cataract surgery procedures performed. Summary statistics were created to determine the number of procedures performed for each outcome of interest: cataract surgery rates by age, sex, race and state; surgical volume by facility type and surgeon characteristics; time interval between first- and second-eye cataract surgery. The national cataract surgery rate for 2003-2004 was 61.8 per 1000 Medicare beneficiary person-years. The rate was significantly higher for females and for those aged 75-84 years. After adjustment for age and sex, blacks had approximately a 30% lower rate of surgery than whites. While only 5% of cataract surgeons performed more than 500 cataract surgeries annually, these surgeons performed 26% of the total cataract surgeries. Increasing surgical volume was found to be highly correlated with use of ambulatory surgical centers and reduced time interval between first- and second-eye surgery in the same patient. The epidemiology of cataract surgery in the United States Medicare population documents substantial variation in surgical rates by race, sex, age, and by certain provider characteristics.

  5. Model surgery with a passive robot arm for orthognathic surgery planning.

    PubMed

    Theodossy, Tamer; Bamber, Mohammad Anwar

    2003-11-01

    The aims of the study were to assess the degree of accuracy of model surgery performed manually using the Eastman technique and to compare it with model surgery performed with the aid of a robot arm. Twenty-one patients undergoing orthognathic surgery gave consent for this study. They were divided into 2 groups based on the model surgery technique used. Group A (52%) had model surgery performed manually, whereas group B (48%) had their model surgery performed using the robot arm. Patients' maxillary casts were measured before and after model surgery, and results were compared with those for the original treatment plan in horizontal (x-axis), vertical (y-axis), and transverse (z-axis) planes. Statistical analysis using Mann-Whitney U test for x- and y-axis and independent sample t test for z-axis have shown significant differences between both groups in x-axis (P =.024) and y-axis (P =.01) but not in z-axis (P =.776). Model surgery performed with the aid of a robot arm is significantly more accurate in anteroposterior and vertical planes than is manual model surgery. Robot arm has an important role to play in orthognathic surgery planning and in determining the biometrics of orthognathic surgical change at the model surgery stage.

  6. Residency Training in Robotic General Surgery: A Survey of Program Directors

    PubMed Central

    George, Lea C.; O'Neill, Rebecca

    2018-01-01

    Objective Robotic surgery continues to expand in minimally invasive surgery; however, the literature is insufficient to understand the current training process for general surgery residents. Therefore, the objectives of this study were to identify the current approach to and perspectives on robotic surgery training. Methods An electronic survey was distributed to general surgery program directors identified by the Accreditation Council for Graduate Medical Education website. Multiple choice and open-ended questions regarding current practices and opinions on robotic surgery training in general surgery residency programs were used. Results 20 program directors were surveyed, a majority being from medium-sized programs (4–7 graduating residents per year). Most respondents (73.68%) had a formal robotic surgery curriculum at their institution, with 63.16% incorporating simulation training. Approximately half of the respondents believe that more time should be dedicated to robotic surgery training (52.63%), with simulation training prior to console use (84.21%). About two-thirds of the respondents (63.16%) believe that a formal robotic surgery curriculum should be established as a part of general surgery residency, with more than half believing that exposure should occur in postgraduate year one (55%). Conclusion A formal robotics curriculum with simulation training and early surgical exposure for general surgery residents should be given consideration in surgical residency training. PMID:29854454

  7. Residency Training in Robotic General Surgery: A Survey of Program Directors.

    PubMed

    George, Lea C; O'Neill, Rebecca; Merchant, Aziz M

    2018-01-01

    Robotic surgery continues to expand in minimally invasive surgery; however, the literature is insufficient to understand the current training process for general surgery residents. Therefore, the objectives of this study were to identify the current approach to and perspectives on robotic surgery training. An electronic survey was distributed to general surgery program directors identified by the Accreditation Council for Graduate Medical Education website. Multiple choice and open-ended questions regarding current practices and opinions on robotic surgery training in general surgery residency programs were used. 20 program directors were surveyed, a majority being from medium-sized programs (4-7 graduating residents per year). Most respondents (73.68%) had a formal robotic surgery curriculum at their institution, with 63.16% incorporating simulation training. Approximately half of the respondents believe that more time should be dedicated to robotic surgery training (52.63%), with simulation training prior to console use (84.21%). About two-thirds of the respondents (63.16%) believe that a formal robotic surgery curriculum should be established as a part of general surgery residency, with more than half believing that exposure should occur in postgraduate year one (55%). A formal robotics curriculum with simulation training and early surgical exposure for general surgery residents should be given consideration in surgical residency training.

  8. IOL Implants: Lens Replacement and Cataract Surgery (Intraocular Lenses)

    MedlinePlus

    ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Academy Publications EyeNet Ophthalmology ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Find an Ophthalmologist Advanced ...

  9. Laparoscopic Surgery

    MedlinePlus

    ... Main ACG Site ACG Patients Home / Digestive Health Topic / Laparoscopic Surgery Laparoscopic Surgery Basics Overview What is laparoscopic surgery? ... with your doctor whether some type of laparoscopic surgery is most suitable for your ... Topics Abdominal Pain Syndrome Belching, Bloating, and Flatulence Common ...

  10. Trends in Accreditation Council for Graduate Medical Education Accreditation for Subspecialty Fellowship Training in Plastic Surgery.

    PubMed

    Silvestre, Jason; Serletti, Joseph M; Chang, Benjamin

    2018-05-01

    The purposes of this study were to (1) determine the proportion of plastic surgery residents pursuing subspecialty training relative to other surgical specialties, and (2) analyze trends in Accreditation Council for Graduate Medical Education accreditation of plastic surgery subspecialty fellowship programs. The American Medical Association provided data on career intentions of surgical chief residents graduating from 2014 to 2016. The percentage of residents pursuing fellowship training was compared by specialty. Trends in the proportion of accredited fellowship programs in craniofacial surgery, hand surgery, and microsurgery were analyzed. The percentage of accredited programs was compared between subspecialties with added-certification options (hand surgery) and subspecialties without added-certification options (craniofacial surgery and microsurgery). Most integrated and independent plastic surgery residents pursued fellowship training (61.8 percent versus 49.6 percent; p = 0.014). Differences existed by specialty from a high in orthopedic surgery (90.8 percent) to a low in colon and rectal surgery (3.2 percent). From 2005 to 2015, the percentage of accredited craniofacial fellowship programs increased, but was not significant (from 27.8 percent to 33.3 percent; p = 0.386). For hand surgery, the proportion of accredited programs that were plastic surgery (p = 0.755) and orthopedic surgery (p = 0.253) was stable, whereas general surgery decreased (p = 0.010). Subspecialty areas with added-certification options had more accredited fellowships than those without (100 percent versus 19.2 percent; p < 0.001). There has been slow adoption of accreditation among plastic surgery subspecialty fellowships, but added-certification options appear to be highly correlated.

  11. Preoperative Lifestyle Intervention in Bariatric Surgery: A Randomized Clinical Trial

    PubMed Central

    Kalarchian, Melissa A.; Marcus, Marsha D.; Courcoulas, Anita P.; Cheng, Yu; Levine, Michele D.

    2015-01-01

    Background Studies of the impact of pre-surgery weight loss and lifestyle preparation on outcomes following bariatric surgery are needed. Objective To evaluate whether a pre-surgery behavioral lifestyle intervention improves weight loss through 24-months post-surgery. Setting Bariatric Center of Excellence at a large, urban medical center. Methods Candidates for bariatric surgery were randomized to a 6-month behavioral lifestyle intervention or to 6 months of usual pre-surgical care. The lifestyle intervention consisted of 8 weekly face-to-face sessions followed by 16 weeks of face-to-face and telephone sessions prior to surgery; the intervention also included 3 monthly telephone contacts after surgery. Assessments were conducted at 6-, 12- and 24-months post-surgery. Results Participants who underwent surgery (n = 143) were 90.2% female and 86.7% White. Average age was 44.9 years, and average BMI was 47.5 kg/m2 at study enrollment. At follow-up, 131 (91.6%), 126 (88.1%), 117 (81.8%) patients participated in the 6-, 12- and 24 month assessments, respectively. Percent weight loss from study enrollment to 6- and 12-months post-surgery was comparable for both groups, but at 24-months post-surgery, the lifestyle group had significantly smaller percent weight loss than the usual care group (26.5% vs. 29.5%, respectively, p = 0.02). Conclusions Pre-surgery lifestyle intervention did not improve weight loss at 24 months post-surgery. Findings raise questions about the utility and timing of adjunctive lifestyle interventions for bariatric surgery patients. PMID:26410538

  12. Adolescent girls' views on cosmetic surgery: A focus group study.

    PubMed

    Ashikali, Eleni-Marina; Dittmar, Helga; Ayers, Susan

    2016-01-01

    This study examined adolescent girls' views of cosmetic surgery. Seven focus groups were run with girls aged 15-18 years (N = 27). Participants read case studies of women having cosmetic surgery, followed by discussion and exploration of their views. Thematic analysis identified four themes: (1) dissatisfaction with appearance, (2) acceptability of cosmetic surgery, (3) feelings about undergoing cosmetic surgery and (4) cosmetic surgery in the media. Results suggest the acceptability of cosmetic surgery varies according to the reasons for having it and that the media play an important role by normalising surgery and under-representing the risks associated with it. © The Author(s) 2014.

  13. Ambulatory surgery and anaesthesia in HUKM, a teaching hospital in Malaysia: the first two years experience.

    PubMed

    Norsidah, A M; Yahya, N; Adeeb, N; Lim, A L

    2001-03-01

    Ambulatory or day care surgery is still in its infancy in this part of the world. Our newly built university affiliated hospital started its Day Surgery Centre in February 1998. It is the first multidisciplinary ambulatory surgery centre in a teaching hospital in the country. It caters for Orthopaedic surgery, Urology, Plastic surgery, Otorhinolaryngology, General surgery, Paediatric surgery and Ophthalmology. We have done 2,604 cases and our unanticipated admission rate is less than 2%. There has been no major morbidity or mortality. The problems of setting up a multidisciplinary ambulatory centre in a teaching hospital are discussed.

  14. Epilepsy Surgery: An Evidence Summary

    PubMed Central

    2012-01-01

    Background The Medical Advisory Secretariat, the predecessor of Health Quality Ontario, published an evidence-based analysis on functional brain imaging. This analysis highlighted the low uptake of epilepsy surgery in Ontario and internationally. Objective The objective of this analysis was to review the effectiveness of epilepsy surgery at reducing seizure frequency, as well as the safety of epilepsy surgery. Data Sources The literature search included studies published between January 1995 and March 2012. Search terms included epilepsy, surgery, resection, safety, and complications. Review Methods Studies were eligible for inclusion if they included at least 20 patients undergoing surgery; had a comparison group of patients with epilepsy who were not undergoing surgery; and reported follow-up periods of at least 1 year. Outcomes of interest included seizure frequency and complications associated with surgery. Results Six systematic reviews reported pooled seizure-free rates that ranged from 43% to 75%. Two randomized controlled trials compared the effectiveness of epilepsy surgery with no surgery in patients with drug-refractory epilepsy. Both trials reported significant improvements in the seizure frequency in the surgery group compared with the nonsurgery group. Eight retrospective cohort studies reported on the safety of epilepsy surgery. Of the 2,725 patients included in these studies, there were 3 deaths reportedly related to surgery. Other complications included hemiparesis, infection, and visual field defects. The studies had long follow-up periods ranging from a mean of 2 to 7 years. Limitations The most recent randomized controlled trial was stopped early due to slow enrolment rates. Thus results need to be interpreted with caution. Conclusions There is high quality evidence that epilepsy surgery is effective at reducing seizure frequency. Two randomized controlled trials compared surgery to no surgery in patients with drug-refractory epilepsy. Both demonstrated significant reductions in seizure frequency. There are some complications associated with epilepsy surgery. In the published literature identified, we observed a 0.1% mortality rate associated with the surgery. Plain Language Summary About 30% of patients with epilepsy continue to have seizures despite optimal drug treatment. In some of these patients, surgery to control the number of seizures may be an option. Patients are carefully selected based on frequency of seizures, location of seizure in the brain, and type of seizures. There is good evidence to indicate that surgery is an effective and safe option for some patients with drug-refractory epilepsy. PMID:23074427

  15. Comparative assessment of physical and cognitive ergonomics associated with robotic and traditional laparoscopic surgeries.

    PubMed

    Lee, Gyusung I; Lee, Mija R; Clanton, Tameka; Clanton, Tamera; Sutton, Erica; Park, Adrian E; Marohn, Michael R

    2014-02-01

    We conducted this study to investigate how physical and cognitive ergonomic workloads would differ between robotic and laparoscopic surgeries and whether any ergonomic differences would be related to surgeons' robotic surgery skill level. Our hypothesis is that the unique features in robotic surgery will demonstrate skill-related results both in substantially less physical and cognitive workload and uncompromised task performance. Thirteen MIS surgeons were recruited for this institutional review board-approved study and divided into three groups based on their robotic surgery experiences: laparoscopy experts with no robotic experience, novices with no or little robotic experience, and robotic experts. Each participant performed six surgical training tasks using traditional laparoscopy and robotic surgery. Physical workload was assessed by using surface electromyography from eight muscles (biceps, triceps, deltoid, trapezius, flexor carpi ulnaris, extensor digitorum, thenar compartment, and erector spinae). Mental workload assessment was conducted using the NASA-TLX. The cumulative muscular workload (CMW) from the biceps and the flexor carpi ulnaris with robotic surgery was significantly lower than with laparoscopy (p < 0.05). Interestingly, the CMW from the trapezius was significantly higher with robotic surgery than with laparoscopy (p < 0.05), but this difference was only observed in laparoscopic experts (LEs) and robotic surgery novices. NASA-TLX analysis showed that both robotic surgery novices and experts expressed lower global workloads with robotic surgery than with laparoscopy, whereas LEs showed higher global workload with robotic surgery (p > 0.05). Robotic surgery experts and novices had significantly higher performance scores with robotic surgery than with laparoscopy (p < 0.05). This study demonstrated that the physical and cognitive ergonomics with robotic surgery were significantly less challenging. Additionally, several ergonomic components were skill-related. Robotic experts could benefit the most from the ergonomic advantages in robotic surgery. These results emphasize the need for well-structured training and well-defined ergonomics guidelines to maximize the benefits utilizing the robotic surgery.

  16. The Impact of Specialty on Cases Performed During Hand Surgery Fellowship Training.

    PubMed

    Silvestre, Jason; Upton, Joseph; Chang, Benjamin; Steinberg, David R

    2018-03-07

    Hand surgery fellowship programs in the United States are predominately sponsored by departments or divisions of orthopaedic surgery or plastic surgery. This study compares the operative experiences of hand surgery fellows graduating from orthopaedic or plastic surgery hand surgery fellowships. Operative case logs of 3 cohorts of hand surgery fellows graduating during the academic years of 2012-2013, 2013-2014, and 2014-2015 were analyzed. The median case volumes were compared by specialty via Mann-Whitney U tests. An arbitrary 1,000% change between the 90th and 10th percentiles of fellows was used as a threshold to highlight case categories with substantial variability. In this study, 413 orthopaedic hand surgery fellows (87%) and 62 plastic surgery hand surgery fellows (13%) were included. Plastic surgery fellows reported more cases in the following categories: wound closure with graft; wound reconstruction with flap; vascular repair, reconstruction, replantation, or microvascular; closed treatment of fracture or dislocation; nerve injury; and congenital (p < 0.05). Orthopaedic surgery fellows reported more cases in the following categories: wound irrigation and debridement fasciotomy or wound preparation; hand reconstruction or releases; wrist reconstruction, releases, or arthrodesis; forearm, elbow, or shoulder reconstruction or releases; hand fractures, dislocation, or ligament injury; wrist fractures or dislocations; forearm and proximal fractures or dislocations; miscellaneous insertion or removal of devices; shoulder arthroscopy, elbow arthroscopy, and wrist arthroscopy; decompression of tendon sheath, synovectomy, or ganglions; nerve decompression; Dupuytren; and tumor or osteomyelitis (p < 0.05). Plastic surgery fellows reported substantial variability for 12 case categories (range, 1,024% to 2,880%). Orthopaedic surgery fellows reported substantial variability for 9 case categories (range, 1,110% to 9,700%). Orthopaedic and plastic hand surgery fellowships afford disparate operative experiences. Understanding these differences may help to align prospective trainees with future career goals and to guide discussions to better standardize hand surgery training.

  17. Comparison of vocal outcomes after angiolytic laser surgery and microflap surgery for vocal polyps.

    PubMed

    Mizuta, Masanobu; Hiwatashi, Nao; Kobayashi, Toshiki; Kaneko, Mami; Tateya, Ichiro; Hirano, Shigeru

    2015-12-01

    The microflap technique is a standard procedure for the treatment of vocal fold polyps. Angiolytic laser surgery carried out under topical anesthesia is an alternative method for vocal polyp removal. However, it is not clear whether angiolytic laser surgery has the same effects on vocal outcomes as the microflap technique because of a lack of studies comparing both procedures. In the current study, vocal outcomes after both procedures were compared to clarify the effects of angiolytic laser surgery for vocal polyp removal. Vocal outcomes were reviewed for patients who underwent angiolytic laser surgery (n=20, laser group) or microflap surgery (n=34, microflap group) for vocal polyp removal. The data analyzed included patient and lesion characteristics, number of surgeries required for complete resolution, and aerodynamic and acoustic examinations before and after surgery. In the laser surgery group, complete resolution of the lesion was achieved with a single procedure in 17 cases (85%) and with two procedures in 3 cases (15%). Postoperative aerodynamic and acoustic parameters demonstrated significant improvement compared to preoperative parameters in both the laser surgery group and the microflap surgery group. There were no significant differences in any postoperative aerodynamic and acoustic parameters between the two groups. The current retrospective study demonstrated that angiolytic laser surgery achieved complete resolution of vocal polyps within two procedures. Postoperative effects on aerodynamic and acoustic functions were similar to those after microflap surgery. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  18. Variable Operative Experience in Hand Surgery for Plastic Surgery Residents.

    PubMed

    Silvestre, Jason; Lin, Ines C; Levin, Lawrence Scott; Chang, Benjamin

    Efforts to standardize hand surgery training during plastic surgery residency remain challenging. We analyze the variability of operative hand experience at U.S. plastic surgery residency programs. Operative case logs of chief residents in accredited U.S. plastic surgery residency programs were analyzed (2011-2015). Trends in fold differences of hand surgery case volume between the 10th and 90th percentiles of residents were assessed graphically. Percentile data were used to calculate the number of residents achieving case minimums in hand surgery for 2015. Case logs from 818 plastic surgery residents were analyzed of which a minority were from integrated (35.7%) versus independent/combined (64.3%) residents. Trend analysis of fold differences in case volume demonstrated decreasing variability among procedure categories over time. By 2015, fold differences for hand reconstruction, tendon cases, nerve cases, arthroplasty/arthrodesis, amputation, arterial repair, Dupuytren release, and neoplasm cases were below 10-fold. Congenital deformity cases among independent/combined residents was the sole category that exceeded 10-fold by 2015. Percentile data suggested that approximately 10% of independent/combined residents did not meet case minimums for arterial repair and congenital deformity in 2015. Variable operative experience during plastic surgery residency may limit adequate exposure to hand surgery for certain residents. Future studies should establish empiric case minimums for plastic surgery residents to ensure hand surgery competency upon graduation. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  19. Association of Patient Age at Gastric Bypass Surgery With Long-term All-Cause and Cause-Specific Mortality.

    PubMed

    Davidson, Lance E; Adams, Ted D; Kim, Jaewhan; Jones, Jessica L; Hashibe, Mia; Taylor, David; Mehta, Tapan; McKinlay, Rodrick; Simper, Steven C; Smith, Sherman C; Hunt, Steven C

    2016-07-01

    Bariatric surgery is effective in reducing all-cause and cause-specific long-term mortality. Whether the long-term mortality benefit of surgery applies to all ages at which surgery is performed is not known. To examine whether gastric bypass surgery is equally effective in reducing mortality in groups undergoing surgery at different ages. All-cause and cause-specific mortality rates and hazard ratios (HRs) were estimated from a retrospective cohort within 4 categories defined by age at surgery: younger than 35 years, 35 through 44 years, 45 through 54 years, and 55 through 74 years. Mean follow-up was 7.2 years. Patients undergoing gastric bypass surgery seen at a private surgical practice from January 1, 1984, through December 31, 2002, were studied. Data analysis was performed from June 12, 2013, to September 6, 2015. A cohort of 7925 patients undergoing gastric bypass surgery and 7925 group-matched, severely obese individuals who did not undergo surgery were identified through driver license records. Matching criteria included year of surgery to year of driver license application, sex, 5-year age groups, and 3 body mass index categories. Roux-en-Y gastric bypass surgery. All-cause and cause-specific mortality compared between those undergoing and not undergoing gastric bypass surgery using HRs. Among the 7925 patients who underwent gastric bypass surgery, the mean (SD) age at surgery was 39.5 (10.5) years, and the mean (SD) presurgical body mass index was 45.3 (7.4). Compared with 7925 matched individuals not undergoing surgery, adjusted all-cause mortality after gastric bypass surgery was significantly lower for patients 35 through 44 years old (HR, 0.54; 95% CI, 0.38-0.77), 45 through 54 years old (HR, 0.43; 95% CI, 0.30-0.62), and 55 through 74 years old (HR, 0.50; 95% CI, 0.31-0.79; P < .003 for all) but was not lower for those younger than 35 years (HR, 1.22; 95% CI, 0.82-1.81; P = .34). The lack of mortality benefit in those undergoing gastric bypass surgery at ages younger than 35 years primarily derived from a significantly higher number of externally caused deaths (HR, 2.53; 95% CI, 1.27-5.07; P = .009), particularly among women (HR, 3.08; 95% CI, 1.4-6.7; P = .005). Patients undergoing gastric bypass surgery had a significantly lower age-related increase in mortality than severely obese individuals not undergoing surgery (P = .001). Gastric bypass surgery was associated with improved long-term survival for all patients undergoing surgery at ages older than 35 years, with externally caused deaths only elevated in younger women. Gastric bypass surgery is protective against mortality even for older patients and also reduces the age-related increase in mortality observed in severely obese individuals not undergoing surgery.

  20. Weight-loss surgery - after - what to ask your doctor

    MedlinePlus

    ... your doctor; What to ask your doctor after weight-loss surgery ... American Society for Metabolic and Bariatric Surgery. Life after bariatric surgery. ASMBS.org web site. asmbs.org/patients/life-after-bariatric-surgery . Accessed February 2, 2017. Mechanick JI, ...

  1. Gastrointestinal robot-assisted surgery. A current perspective.

    PubMed

    Lunca, Sorinel; Bouras, George; Stanescu, Alexandru Calin

    2005-12-01

    Minimally invasive techniques have revolutionized operative surgery. Computer aided surgery and robotic surgical systems strive to improve further on currently available minimally invasive surgery and open new horizons. Only several centers are currently using surgical robots and publishing data. In gastrointestinal surgery, robotic surgery is applied to a wide range of procedures, but is still in its infancy. Cholecystectomy, Nissen fundoplication and Heller myotomy are among the most frequently performed operations. The ZEUS (Computer Motion, Goleta, CA) and the da Vinci (Intuitive Surgical, Mountain View, CA) surgical systems are today the most advanced robotic systems used in gastrointestinal surgery. Most studies reported that robotic gastrointestinal surgery is feasible and safe, provides improved dexterity, better visualization, reduced fatigue and high levels of precision when compared to conventional laparoscopic surgery. Its main drawbacks are the absence of force feedback and extremely high costs. At this moment there are no reports to clearly demonstrate the superiority of robotics over conventional laparoscopic surgery. Further research and more prospective randomized trials are needed to better define the optimal application of this new technology in gastrointestinal surgery.

  2. Does the NBME Surgery Shelf exam constitute a "double jeopardy" of USMLE Step 1 performance?

    PubMed

    Ryan, Michael S; Colbert-Getz, Jorie M; Glenn, Salem N; Browning, Joel D; Anand, Rahul J

    2017-02-01

    Scores from the NBME Subject Examination in Surgery (Surgery Shelf) positively correlate with United States Medical Licensing Examination Step 1 (Step 1). Based on this relationship, the authors evaluated the predictive value of Step 1 on the Surgery Shelf. Surgery Shelf standard scores were substituted for Step 1 standard scores for 395 students in 2012-2014 at one medical school. Linear regression was used to determine how well Step 1 scores predicted Surgery Shelf scores. Percent match between original (with Shelf) and modified (with Step 1) clerkship grades were computed. Step 1 scores significantly predicted Surgery Shelf scores, R 2  = 0.42, P < 0.001. For every point increase in Step 1, a Surgery Shelf score increased by 0.30 points. Seventy-seven percent of original grades matched the modified grades. Replacing Surgery Shelf scores with Step 1 scores did not have an effect on the majority of final clerkship grades. This observation raises concern over use of Surgery Shelf scores as a measure of knowledge obtained during the Surgery clerkship. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Characteristics of the population eligible for and receiving publicly funded bariatric surgery in Canada

    PubMed Central

    2012-01-01

    Background Bariatric surgery is the most effective current treatment for severe obesity. Capacity to perform surgery within Canada’s public health system is limited and potential candidates face protracted wait times. A better understanding of the gaps between demand for surgery and the capacity to provide it is required. The purpose of this study was to quantify and characterize the bariatric surgery-eligible population in Canada in comparison to surgery-ineligible subjects and surgical recipients. Methods Data from adult (age > 20) respondents of the 2007–09 nationally representative Canadian Health Measures Survey (CHMS) were analyzed to estimate the prevalence and characteristics of the surgery-eligible and ineligible populations. Federally mandated administrative healthcare data (2007–08) were used to characterize surgical recipients. Results In 2007–09, an estimated 1.5 million obese Canadian adults met eligibility criteria for bariatric surgery. 19.2 million were surgery-ineligible (3.4 million obese and 15.8 million non-obese). Surgery-eligible Canadians had a mean BMI of 40.1 kg/m2 (95% CI 39.3 to 40.9 kg/m2) and, compared to the surgery-ineligible obese population, were more likely to be female (62 vs. 44%), 40–59 years old (55 vs. 48%), less educated (43 vs. 35%), in the lowest socioeconomic tertile (41 vs. 34%), and inactive (73 vs. 59%). Self-rated mental health and quality of life were lower and comorbidity was higher in surgery-eligible respondents compared with the ineligible populations. The annual proportion of Canadians eligible for surgery that actually underwent a publicly funded bariatric surgery between 2007–09 was 0.1%. Surgical recipients (n = 847) had a mean age of 43.6 years (SD 11.1) and 82% were female. With the exception of type 2 diabetes, obesity-related comorbidity prevalence was much lower in surgical recipients compared to those eligible for surgery. Conclusions The proportion of bariatric surgery-eligible Canadians that undergo publicly funded bariatric surgery is very low. There are notable differences in sociodemographic profiles and prevalence of comorbidities between surgery-eligible subjects and surgical recipients. PMID:22984790

  4. Sex, race, and consideration of bariatric surgery among primary care patients with moderate to severe obesity.

    PubMed

    Wee, Christina C; Huskey, Karen W; Bolcic-Jankovic, Dragana; Colten, Mary Ellen; Davis, Roger B; Hamel, Marybeth

    2014-01-01

    Bariatric surgery is one of few obesity treatments to produce substantial weight loss but only a small proportion of medically-eligible patients, especially men and racial minorities, undergo bariatric surgery. To describe primary care patients' consideration of bariatric surgery, potential variation by sex and race, and factors that underlie any variation. Telephone interview of 337 patients with a body mass index or BMI > 35 kg/m(2) seen at four diverse primary care practices in Greater-Boston. Patients' consideration of bariatric surgery. Of 325 patients who had heard of bariatric surgery, 34 % had seriously considered surgery. Men were less likely than women and African Americans were less likely than Caucasian patients to have considered surgery after adjustment for sociodemographics and BMI. Comorbid conditions did not explain sex and racial differences but racial differences dissipated after adjustment for quality of life (QOL), which tended to be higher among African American than Caucasian patients. Physician recommendation of bariatric surgery was independently associated with serious consideration for surgery [OR 4.95 (95 % CI 2.81-8.70)], but did not explain variation in consideration of surgery across sex and race. However, if recommended by their doctor, men were as willing and African American and Hispanic patients were more willing to consider bariatric surgery than their respective counterparts after adjustment. Nevertheless, only 20 % of patients reported being recommended bariatric surgery by their doctor and African Americans and men were less likely to receive this recommendation; racial differences in being recommended surgery were also largely explained by differences in QOL. High perceived risk to bariatric surgery was the most commonly cited barrier; financial concerns were uncommonly cited. Single geographic region; examined consideration and not who eventually proceeded with bariatric surgery. African Americans and men were less likely to have considered bariatric surgery and were less likely to have been recommended surgery by their doctors. Differences in how obesity affects QOL appear to account for some of these variations. High perceived risk rather than financial barrier was the major deterrent for patients.

  5. Lack of nationwide Danish guidelines on mammography before non-oncological breast surgery.

    PubMed

    Foged, Thomas; Sørensen, Jens Ahm; Søe, Katrine Lydolph; Bille, Camilla

    2015-05-01

    Non-oncological breast surgery like breast reduction and mastopexy are often performed in younger patients, i.e. in women who have not yet had mammography. Breast cancer is, however, a very frequent disease that is increasingly prevalent in women below 50 years of age. Occult breast cancer may not be recognised before breast surgery, which may result in several disadvantages for the women. Therefore, detecting a breast cancer before a woman undergoes non-oncological breast surgery is of paramount importance. All public plastic surgery and breast surgery departments and all private clinics or hospitals providing plastic surgery were asked two questions: 1) When do you recommend a mammography prior to non-oncological breast surgery? 2) How old must a mammogram be before it needs to be repeated? Answers were received from all plastic surgery and breast surgery departments, and all but three of the private clinics and hospitals. Overall, information was obtained from 95.5% of the respondents (n = 63). Currently, there are no Danish guidelines on mammography before non-oncological breast surgery. A national guideline could recommend a preoperative mammogram from the age of 40 years stipulating that the mammogram should have been made within the past 12 months; however, the final recommendation should be prepared by a multidisciplinary working group counting experts from plastic surgery, breast surgery, pathology and radiology. not relevant. not relevant.

  6. Cataract Surgery among Medicare Beneficiaries

    PubMed Central

    Schein, Oliver D.; Cassard, Sandra D.; Tielsch, James M.; Gower, Emily W.

    2014-01-01

    Purpose To present descriptive epidemiology of cataract surgery among Medicare recipients in the United States. Setting Cataract surgery performed on Medicare beneficiaries in 2003 and 2004. Methods Medicare claims data were used to identify all cataract surgery claims for procedures performed in the United States in 2003-2004. Standard assumptions were used to limit the claims to actual cataract surgery procedures performed. Summary statistics were created to determine the number of procedures performed for each outcome of interest: cataract surgery rates by age, race, and gender; surgical volume by facility type, surgeon characteristics, and state; time interval between first- and second-eye cataract surgery. Results The national cataract surgery rate for 2003-2004 was 61.8 per 1000 Medicare beneficiary person-years. The rate was significantly higher for females and for those 75-84. After adjustment for age and gender, blacks had approximately a 30% lower rate of surgery than whites. While only 5% of cataract surgeons performed more than 500 cataract surgeries annually, these surgeons performed 26% of the total cataract surgeries. Increasing surgical volume was found to be highly correlated with use of ambulatory surgical centers and reduced time interval between first- and second-eye surgery in the same patient. Conclusions The epidemiology of cataract surgery in the United States Medicare population documents substantial variation in surgical rates by race, gender, age, and by certain provider characteristics. PMID:22978526

  7. An integrated orthognathic surgery system for virtual planning and image-guided transfer without intermediate splint.

    PubMed

    Kim, Dae-Seung; Woo, Sang-Yoon; Yang, Hoon Joo; Huh, Kyung-Hoe; Lee, Sam-Sun; Heo, Min-Suk; Choi, Soon-Chul; Hwang, Soon Jung; Yi, Won-Jin

    2014-12-01

    Accurate surgical planning and transfer of the planning in orthognathic surgery are very important in achieving a successful surgical outcome with appropriate improvement. Conventionally, the paper surgery is performed based on a 2D cephalometric radiograph, and the results are expressed using cast models and an articulator. We developed an integrated orthognathic surgery system with 3D virtual planning and image-guided transfer. The maxillary surgery of orthognathic patients was planned virtually, and the planning results were transferred to the cast model by image guidance. During virtual planning, the displacement of the reference points was confirmed by the displacement from conventional paper surgery at each procedure. The results of virtual surgery were transferred to the physical cast models directly through image guidance. The root mean square (RMS) difference between virtual surgery and conventional model surgery was 0.75 ± 0.51 mm for 12 patients. The RMS difference between virtual surgery and image-guidance results was 0.78 ± 0.52 mm, which showed no significant difference from the difference of conventional model surgery. The image-guided orthognathic surgery system integrated with virtual planning will replace physical model surgical planning and enable transfer of the virtual planning directly without the need for an intermediate splint. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  8. Nanotechnology applications in plastic and reconstructive surgery: a review.

    PubMed

    Parks, Joe; Kath, Melissa; Gabrick, Kyle; Ver Halen, Jon Peter

    2012-01-01

    Although nanotechnology is a relatively young field, there are already countless biomedical applications. Plastic and reconstructive surgery has significantly benefited from nanoscale refinements of diagnostic and therapeutic techniques. Plastic surgery is an incredibly diverse specialty, encompassing craniofacial surgery, hand surgery, cancer/trauma/congenital reconstruction, burn care, and aesthetic surgery. In particular, wound care, topical skin care, implant and prosthetic design, tissue engineering, regenerative medicine, and drug delivery have all been influenced by advances in nanotechnology. Nanotechnology will continue to witness growth and expansion of its biomedical applications, especially those in plastic surgery.

  9. [History of cranial surgery, cerebral tumor surgery and epilepsy surgery in Mexico].

    PubMed

    Chico-Ponce de León, F

    2009-08-01

    The first report of intra-cerebral tumor surgery was provided by Bennett & Goodle, in London, 1884. Worldwide this kind of surgery was performed in France by Chipault, in Italy by Durante, in the United States by Keen and in Deutchland by Krause & Oppenheim. Lavista in Mexico City operated on intra-cerebral tumor in 1891, and the report was printed in 1892. In the same publication, Lavista exhibited the first cases of epilepsy surgery. Since now, it is the first report of this kind of surgery in the Spanish-speaking world.

  10. Hand surgery volume and the US economy: is there a statistical correlation?

    PubMed

    Gordon, Chad R; Pryor, Landon; Afifi, Ahmed M; Gatherwright, James R; Evans, Peter J; Hendrickson, Mark; Bernard, Steven; Zins, James E

    2010-11-01

    To the best of our knowledge, there have been no previous studies evaluating the correlation of the US economy and hand surgery volume. Therefore, in light of the current recession, our objective was to study our institution's hand surgery volume over the last 17 years in relation to the nation's economy. A retrospective analysis of our institution's hand surgery volume, as represented by our most common procedure (ie, carpal tunnel release), was performed between January 1992 and October 2008. Liposuction and breast augmentation volumes were chosen to serve as cosmetic plastic surgery comparison groups. Pearson correlation statistics were used to estimate the relationship between the surgical volume and the US economy, as represented by the 3 market indices (Dow Jones, NASDAQ, and S&P500). A combined total of 7884 hand surgery carpal tunnel release (open or endoscopic) patients were identified. There were 1927 (24%) and 5957 (76%) patients within the departments of plastic and orthopedic surgery, respectively. In the plastic surgery department, there was a strong negative (ie, inverse relationship) correlation between hand surgery volume and the economy (P < 0.001). In converse, the orthopedic department's hand surgery volume demonstrated a positive (ie, parallel) correlation (P < 0.001). The volumes of liposuction and breast augmentation also showed a positive correlation (P < 0.001). To our knowledge, we have demonstrated for the first time an inverse (ie, negative) correlation between hand surgery volumes performed by plastic surgeons in relation to the US economy, as represented by the 3 major market indices. In contrast, orthopedic hand surgery volume and cosmetic surgery show a parallel (ie, positive) correlation. This data suggests that plastic surgeons are increasing their cosmetic surgery-to-reconstructive/hand surgery ratio during strong economic times and vice versa during times of economic slowdown.

  11. Quality of life long-term after body contouring surgery following bariatric surgery: sustained improvement after 7 years.

    PubMed

    van der Beek, Eva S J; Geenen, Rinie; de Heer, Francine A G; van der Molen, Aebele B Mink; van Ramshorst, Bert

    2012-11-01

    Bariatric surgery for morbid obesity results in massive weight loss and improvement of health and quality of life. A downside of the major weight loss is the excess of overstretched skin, which may influence the patient's quality of life by causing functional and aesthetic problems. The purpose of the current study was to evaluate the patient's quality of life long-term after body contouring following bariatric surgery. Quality of life was measured with the Obesity Psychosocial State Questionnaire in 33 post-bariatric surgery patients 7.2 years (range, 3.2 to 13.3 years) after body contouring surgery. Data were compared with previous assessments 4.1 years (range, 0.7 to 9.2 years) after body contouring surgery of the quality of life at that time and before body contouring surgery. Compared with appraisals of quality of life before body contouring surgery, a significant, mostly moderate to large, sustained improvement of quality of life was observed in post-bariatric surgery patients 7.2 years after body contouring surgery in six of the seven psychosocial domains. A small deterioration occurred between 4.1- and 7.2-year follow-up on two of the seven domains except for the domain efficacy toward eating, which showed a significant improvement. At 7-year follow-up, 18 patients (55 percent) were satisfied with the result of body contouring surgery. This study indicates a sustained quality-of-life improvement in post-bariatric surgery patients after body contouring surgery. This suggests the importance of including reconstructive surgery as a component in the multidisciplinary approach in the surgical treatment of morbid obesity. Therapeutic, IV.

  12. Cochlear implant revision surgeries in children.

    PubMed

    Amaral, Maria Stella Arantes do; Reis, Ana Cláudia Mirândola B; Massuda, Eduardo T; Hyppolito, Miguel Angelo

    2018-02-16

    The surgery during which the cochlear implant internal device is implanted is not entirely free of risks and may produce problems that will require revision surgeries. To verify the indications for cochlear implantation revision surgery for the cochlear implant internal device, its effectiveness and its correlation with certain variables related to language and hearing. A retrospective study of patients under 18 years submitted to cochlear implant Surgery from 2004 to 2015 in a public hospital in Brazil. Data collected were: age at the time of implantation, gender, etiology of the hearing loss, audiological and oral language characteristics of each patient before and after Cochlear Implant surgery and any need for surgical revision and the reason for it. Two hundred and sixty-five surgeries were performed in 236 patients. Eight patients received a bilateral cochlear implant and 10 patients required revision surgery. Thirty-two surgeries were necessary for these 10 children (1 bilateral cochlear implant), of which 21 were revision surgeries. In 2 children, cochlear implant removal was necessary, without reimplantation, one with cochlear malformation due to incomplete partition type I and another due to trauma. With respect to the cause for revision surgery, of the 8 children who were successfully reimplanted, four had cochlear calcification following meningitis, one followed trauma, one exhibited a facial nerve malformation, one experienced a failure of the cochlear implant internal device and one revision surgery was necessary because the electrode was twisted. The incidence of the cochlear implant revision surgery was 4.23%. The period following the revision surgeries revealed an improvement in the subject's hearing and language performance, indicating that these surgeries are valid in most cases. Copyright © 2018 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  13. Epilepsy Surgery Series: A Study of 502 Consecutive Patients from a Developing Country

    PubMed Central

    Al-Otaibi, Faisal; Baz, Salah; Althubaiti, Ibrahim; Aldhalaan, Hisham; MacDonald, David; Abalkhail, Tareq; Fiol, Miguel E.; Alyamani, Suad; Chedrawi, Aziza; Leblanc, Frank; Parrent, Andrew; Maclean, Donald; Girvin, John

    2014-01-01

    Purpose. To review the postoperative seizure outcomes of patients that underwent surgery for epilepsy at King Faisal Specialist Hospital & Research Centre (KFSHRC). Methods. A descriptive retrospective study for 502 patients operated on for medically intractable epilepsy between 1998 and 2012. The surgical outcome was measured using the ILAE criteria. Results. The epilepsy surgery outcome for temporal lobe epilepsy surgery (ILAE classes 1, 2, and 3) at 12, 36, and 60 months is 79.6%, 74.2%, and 67%, respectively. The favorable 12- and 36-month outcomes for frontal lobe epilepsy surgery are 62% and 52%, respectively. For both parietal and occipital epilepsy lobe surgeries the 12- and 36-month outcomes are 67%. For multilobar epilepsy surgery, the 12- and 36-month outcomes are 65% and 50%, respectively. The 12- and 36-month outcomes for functional hemispherectomy epilepsy surgery are 64.2% and 63%, respectively. According to histopathology diagnosis, mesiotemporal sclerosis (MTS) and benign CNS tumors had the best favorable outcome after surgery at 1 year (77.27% and 84.3%, resp.,) and 3 years (76% and 75%, resp.,). The least favorable seizure-free outcome after 3 years occurred in cases with dual pathology (66.6%). Thirty-four epilepsy patients with normal magnetic resonance imaging (MRI) brain scans were surgically treated. The first- and third-year epilepsy surgery outcome of 17 temporal lobe surgeries were (53%) and (47%) seizure-free, respectively. The first- and third-year epilepsy surgery outcomes of 15 extratemporal epilepsy surgeries were (47%) and (33%) seizure-free. Conclusion. The best outcomes are achieved with temporal epilepsy surgery, mesial temporal sclerosis, and benign CNS tumor. The worst outcomes are from multilobar surgery, dual pathology, and normal MRI. PMID:24627805

  14. Increasing Utilization Of Pediatric Epilepsy Surgery In The United States Between 1997 and 2009

    PubMed Central

    Pestana Knight, Elia M.; Schiltz, Nicholas K.; Bakaki, Paul M.; Koroukian, Siran M.; Lhatoo, Samden D.; Kaiboriboon, Kitti

    2014-01-01

    SUMMARY OBJECTIVE To examine national trends of pediatric epilepsy surgery usage in the United States between 1997 and 2009. METHODS We performed a serial cross-sectional study of pediatric epilepsy surgery using triennial data from the Kids’ Inpatient Database from 1997 to 2009. The rates of epilepsy surgery for lobectomies, partial lobectomies, and hemispherectomies in each study year were calculated based on the number of prevalent epilepsy cases in the corresponding year. The age-race-sex adjusted rates of surgeries were also estimated. Mann-Kendall trend test was used to test for changes in the rates of surgeries over time. Multivariable regression analysis was also performed to estimate the effect of time, age, race, and sex on the annual incidence of epilepsy surgery. RESULTS The rates of pediatric epilepsy surgery significantly increased from 0.85 epilepsy surgeries per 1,000 children with epilepsy in 1997 to 1.44 epilepsy surgeries per 1,000 children with epilepsy in 2009. An increment in the rates of epilepsy surgeries was noted across all age groups, in boys and girls, all races, and all payer types. The rate of increase was lowest in blacks and in children with public insurance. The overall number of surgical cases for each study year was lower than 35% of children who were expected to have surgery, based on the estimates from the Connecticut Study of Epilepsy. SIGNIFICANCE In contrast to adults, pediatric epilepsy surgery numbers have increased significantly in the past decade. However, epilepsy surgery remains an underutilized treatment for children with epilepsy. In addition, black children and those with public insurance continue to face disparities in the receipt of epilepsy surgery. PMID:25630252

  15. The success rate of TED upper eyelid retraction reoperations.

    PubMed

    Golan, Shani; Rootman, Dan B; Goldberg, Robert A

    2016-12-01

    Although reoperation rates for upper lid retraction surgery for thyroid eye disease (TED) typically range between 8% and 23%, there is little literature describing the outcomes of these second operations. In this retrospective observational cohort study, all patients that underwent surgery for upper eyelid retraction over a 14-year period at a single institution were included. Cases were included if a second eyelid retraction surgery was performed during the study period. Success of surgery was defined as a marginal reflex distance (MRD1) of 2.5 to 4.5 mm in each eye and less than 1 mm difference in MRD1 between the eyes. Overcorrection and undercorrection were defined as above and below these bounds, respectively. 72 eyes in 49 patients were included in the study. The mean age was 56.6 (±11.5) years. By definition, all patients had at least 1 lid lengthening surgery for upper eyelid retraction, and at least 1 subsequent surgery. For this second surgery, 61 eyes (85%) underwent retraction surgery and 11 eyes (15%) underwent ptosis surgery. After this second operation, 31% were undercorrected and 33% were overcorrected. A third surgery was performed in 19 eyes (25%), 12 had surgery for residual retraction and 7 for ptosis. After the third operation 10% of eyes were under corrected and 11% were over corrected. Four patients underwent a fourth surgery: one for retraction and three for ptosis. Success was noted in 35% after the second surgery and 44% after the third. Surgical success in eyelid retraction surgery increases from a second to a third consecutive surgery, and residual asymmetry was roughly equally distributed between over- and undercorrection.

  16. Impact of bariatric surgery on outcomes of patients with nonalcoholic fatty liver disease: a nationwide inpatient sample analysis, 2004-2012.

    PubMed

    McCarty, Thomas R; Echouffo-Tcheugui, Justin B; Lange, Andrew; Haque, Lamia; Njei, Basile

    2018-01-01

    Bariatric surgery in eligible morbidly obese individuals may improve liver steatosis, inflammation, and fibrosis; however, population-based data on the clinical benefits of bariatric surgery in patients with nonalcoholic fatty liver disease (NAFLD) are lacking. To assess the relationship between bariatric surgery and clinical outcomes in hospitalized patients with NAFLD. United States inpatient care database. The Nationwide Inpatient Sample database was queried from 2004 to 2012 with co-diagnoses of NAFLD and morbid obesity. Hospitalizations with a history of prior bariatric surgery (Roux-en-Y gastric bypass, gastric band, and sleeve gastrectomy) were also identified. The primary outcome was in-hospital mortality. Secondary outcomes included cirrhosis, myocardial infarction, stroke, and renal failure. Poisson regression was used to derive adjusted incidence risk ratios for clinical outcomes in patients with prior bariatric surgery compared with those without bariatric surgery. Among 45,462 patients with a discharge diagnosis of NAFLD and morbid obesity, 18,618 patients (41.0%) had prior bariatric surgery. There was a downward trend in bariatric surgery procedures (percent annual change of -5.94% from 2004 to 2012). In a multivariable analysis, prior bariatric surgery was associated with decreased inpatient mortality compared with no bariatric surgery (incidence risk ratios = .08; 95% confidence interval, .03-.20, P<.001). Prior bariatric surgery was also associated with decreased incidence risk ratios for cirrhosis, myocardial infarction, stroke, and renal failure (all P<.001). Prior bariatric surgery is associated with decreased in-hospital morbidity and mortality in morbidly obese NAFLD patients. Despite this, the proportion of NAFLD patients with bariatric surgery has declined from 2004 to 2012. Copyright © 2018 American Society for Bariatric Surgery. Published by Elsevier Inc. All rights reserved.

  17. Plastic surgery in bariatric patients: a nationwide study of 17,000 patients on the national administrative database.

    PubMed

    Lazzati, Andrea; Katsahian, Sandrine; Maladry, David; Gerard, Emma; Gaucher, Sonia

    2018-05-01

    Bariatric patients are often candidates for plastic surgery. However, the rate of postbariatric procedures is not known. The aim of this study was to analyze the rate of plastic surgery, and factors related to surgery, in bariatric patients. University hospital, France. This was a cohort study based on administrative data. All adult patients who received bariatric surgery in France between 2007 and 2013 were included to estimate the rate of plastic surgery and related predictive factors. Data are reported according to the reporting of studies conducted using observational routinely collected data guidelines for observational studies on administrative data. Among the 183,514 patients who underwent bariatric surgery in the study period, 23,120 plastic surgeries were performed on 17,695 patients, including abdominoplasty (62%), dermolipectomy of the upper or lower limbs (25%), and reconstruction of the breast (14%). The rates of plastic surgery were 13%, 18%, and 21% at 3, 5, and 7 years post-bariatric surgery, respectively. Multivariate analysis revealed that patients who had a biliopancreatic diversion or a gastric bypass had a hazard ratio of 2.67 and 2.67 for subsequent plastic surgery, respectively, compared with patients who had adjustable gastric banding. Women had a 2-fold probability of surgery compared with men (hazard ratio 2.02). Important variability in the rate of surgery was found among different hospitals; rates ranged from 6.1% to 41.3% at 5 years. This study showed that 21% of bariatric patients undergo plastic surgery. Large variability exists among hospitals, suggesting that several unmeasured factors may limit access to contouring surgery. Copyright © 2018. Published by Elsevier Inc.

  18. Hospital-level Variation in Utilization of Surgery for Clinical Stage I-II Pancreatic Adenocarcinoma.

    PubMed

    Swords, Douglas S; Mulvihill, Sean J; Skarda, David E; Finlayson, Samuel R G; Stoddard, Gregory J; Ott, Mark J; Firpo, Matthew A; Scaife, Courtney L

    2017-07-11

    To (1) evaluate rates of surgery for clinical stage I-II pancreatic ductal adenocarcinoma (PDAC), (2) identify predictors of not undergoing surgery, (3) quantify the degree to which patient- and hospital-level factors explain differences in hospital surgery rates, and (4) evaluate the association between adjusted hospital-specific surgery rates and overall survival (OS) of patients treated at different hospitals. Curative-intent surgery for potentially resectable PDAC is underutilized in the United States. Retrospective cohort study of patients ≤85 years with clinical stage I-II PDAC in the 2004 to 2014 National Cancer Database. Mixed effects multivariable models were used to characterize hospital-level variation across quintiles of hospital surgery rates. Multivariable Cox proportional hazards models were used to estimate the effect of adjusted hospital surgery rates on OS. Of 58,553 patients without contraindications or refusal of surgery, 63.8% underwent surgery, and the rate decreased from 2299/3528 (65.2%) in 2004 to 4412/7092 (62.2%) in 2014 (P < 0.001). Adjusted hospital rates of surgery varied 6-fold (11.4%-70.9%). Patients treated at hospitals with higher rates of surgery had better unadjusted OS (median OS 10.2, 13.3, 14.2, 16.5, and 18.4 months in quintiles 1-5, respectively, P < 0.001, log-rank). Treatment at hospitals in lower surgery rate quintiles 1-3 was independently associated with mortality [Hazard ratio (HR) 1.10 (1.01, 1.21), HR 1.08 (1.02, 1.15), and HR 1.09 (1.04, 1.14) for quintiles 1-3, respectively, compared with quintile 5] after adjusting for patient factors, hospital type, and hospital volume. Quality improvement efforts are needed to help hospitals with low rates of surgery ensure that their patients have access to appropriate surgery.

  19. Comparison of intraocular pressure fluctuations before and after ab interno trabeculectomy in pseudoexfoliation glaucoma patients

    PubMed Central

    Tojo, Naoki; Abe, Shinya; Miyakoshi, Mari; Hayashi, Atsushi

    2017-01-01

    Purpose Ab interno trabeculectomy (AIT) with the Trabectome has been shown to reduce intraocular pressure (IOP) in eyes with pseudoexfoliation (PEX) glaucoma. Here, we examined the change of IOP fluctuations before and after only AIT or AIT with cataract surgery in PEX patients using the contact lens sensor Triggerfish®. Methods This was a prospective open-label study. Twenty-four consecutive patients with PEX glaucoma were included. Twelve patients underwent cataract surgery and AIT (triple-surgery group), and 12 patients underwent only AIT (single-surgery group). In each eye, IOP fluctuations over 24 h were measured with the contact lens sensor before and at 3 months after the surgery. We compared the change of IOP fluctuation before and after operation. We also evaluated the difference in IOP changes between the triple- and single-surgery groups. Results At 3 months after the surgeries, the mean IOP was significantly reduced from 23.5±6.5 mmHg to 14.6±2.8 mmHg in the single-surgery group and from 22.5±3.0 mmHg to 11.5±2.9 mmHg in the triple-surgery group. The mean IOP reduction rate was significantly higher in the triple-surgery group compared to the single-surgery group (p=0.0358). In both groups, the mean range of IOP fluctuations was significantly decreased during nocturnal periods. The mean range of 24 h IOP fluctuations was decreased in the triple-surgery group (p=0.00425), not in the single-surgery group (p=0.970). Conclusion Triple surgery could decrease IOP value and the IOP fluctuations to a greater extent than single surgery in PEX glaucoma patients. PMID:28979095

  20. Contemporary indications for transsphenoidal pituitary surgery.

    PubMed

    Miller, Brandon A; Ioachimescu, Adriana G; Oyesiku, Nelson M

    2014-12-01

    To analyze current indications for transsphenoidal pituitary surgery. The current literature regarding transsphenoidal surgery for all subtypes of pituitary adenomas and other sellar lesions was examined. Alternate approaches for pituitary surgery were also reviewed. Transsphenoidal surgery continues to be the mainstay of surgical treatment for pituitary tumors, and has good outcomes in experienced hands. Pre- and postoperative management of pituitary tumors remains an important part of the treatment of patients with pituitary tumors. Even as medical and surgical treatment for pituitary tumors evolves, transsphenoidal surgery remains a mainstay of treatment. Outcomes after transshenoidal surgery have improved over time. Neurosurgeons must be aware of the indications, risks and alternatives to transsphenoidal pituitary surgery. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. [Chronic surplus of Japanese cardiac surgeon--ideal nurse practitioner for cardiac surgery, cardiac surgeon's attitude toward the future].

    PubMed

    Ikegami, Hirohisa

    2014-03-01

    It is chronically surplus of doctors in the world of cardiac surgery. There are too many cardiac surgeons because cardiac surgery requires a large amount of manpower resources to provide adequate medical services. Many Japanese cardiac surgeons do not have enough opportunity to perform cardiac surgery operations, and many Japanese cardiac surgery residents do not have enough opportunity to learn cardiac surgery operations. There are physician assistants and nurse practitioners in the US. Because they provide a part of medical care to cardiac surgery patients, American cardiac surgeons can focus more energy on operative procedures. Introduction of cardiac surgery specialized nurse practitioner is essential to deliver a high quality medical service as well as to solve chronic problems that Japanese cardiac surgery has had for a long time.

  2. Transgender Surgery in Denmark From 1994 to 2015: 20-Year Follow-Up Study.

    PubMed

    Aydin, Dogu; Buk, Liv Johanne; Partoft, Søren; Bonde, Christian; Thomsen, Michael Vestergaard; Tos, Tina

    2016-04-01

    Gender dysphoria is a mismatch between a person's biological sex and gender identity. The best treatment is believed to be hormonal therapy and gender-confirming surgery that will transition the individual toward the desired gender. Treatment in Denmark is covered by public health care, and gender-confirming surgery in Denmark is centralized at a single-center with few specialized plastic surgeons conducting top surgery (mastectomy or breast augmentation) and bottom surgery (vaginoplasty or phalloplasty and metoidioplasty). To report the first nationwide single-center review on transsexual patients in Denmark undergoing gender-confirming surgery performed by a single surgical team and to assess whether age at time of gender-confirming surgery decreased during a 20-year period. Electronic patient databases were used to identify patients diagnosed with gender identity disorders from January 1994 through March 2015. Patients were excluded from the study if they were pseudohermaphrodites or if their gender was not reported. Gender distribution, age trends, and surgeries performed for Danish patients who underwent gender-confirming surgery. One hundred fifty-eight patients referred for gender-confirming surgery were included. Fifty-five cases (35%) were male-to-female (MtF) and 103 (65%) were female-to-male (FtM). In total, 126 gender-confirming surgeries were performed. For FtM cases, top surgery (mastectomy) was conducted in 62 patients and bottom surgery (phalloplasty and metoidioplasty) was conducted in 17 patients. For MtF cases, 45 underwent bottom surgery (vaginoplasty), 2 of whom received breast augmentation. The FtM:MtF ratio of the referred patients was 1.9:1. The median age at the time of surgery decreased from 40 to 27 years during the 20-year period. Gender-confirming surgery was performed on 65 FtM and 40 MtF cases at our hospital, and 21 transsexuals underwent surgery abroad. Mastectomy was performed in 62 FtM and bottom surgery in 17 FtM cases. Vaginoplasty was performed in 45 MtF and breast augmentation in 2 MtF cases. There was a significant decrease in age at the time of gender-confirming surgery during the course of the study period. Copyright © 2016 International Society for Sexual Medicine. Published by Elsevier Inc. All rights reserved.

  3. Recovery Following Orthognathic Surgery

    DTIC Science & Technology

    1993-01-01

    surgery.10 Recreational and social activity was reduced after surgery and gradually increased to a level higher than before surgery at 4 months. At 9...from 3 weeks to 4 months after surgery. Previous studies of orthognathic surgery patients have suggested that thorough preoperative education of the...occurring to restore the patient to the presu ~rgi- cal state. Numerous factors may affect the process and its ultimate outcome, but the complex process also

  4. The incidence and causative organisms of infection in elective shoulder surgery.

    PubMed

    Mayne, Alistair I W; Bidwai, Amit S; Clifford, Rachael; Smith, Matthew G; Guisasola, Inigo; Brownson, Peter

    2018-07-01

    Deep infection remains a serious complication of orthopaedic surgery. Knowledge of infection rates and causative organisms is important to guide infection control measures. The aim of the present study was to determine infection rates and causative organisms in elective shoulder surgery. Cases complicated by infection were identified and prospectively recorded over a 2-year period. All patients undergoing elective shoulder surgery in the concurrent period at a single Specialist Upper Limb Unit in the UK were identified from the hospital electronic database. In total, 1574 elective shoulder cases were performed: 1359 arthroscopic (540 with implant insertion) and 215 open (197 with implant insertion). The overall infection rate in open surgery of 2.5% was significantly higher than arthroscopic implant cases at 0.7% ( p  < 0.005). The overall infection rate in implant arthroscopic surgery was significantly higher at 0.7% compared to 0% in non-implant related surgery. ( p  < 0.05). Patients undergoing open shoulder surgery have a significantly higher risk of infection compared to arthroscopic shoulder surgery. Arthroscopic surgery with implant insertion has a statistically significantly higher risk of developing deep infection compared to procedures with no implant insertion. We recommend prophylactic antibiotics in open shoulder surgery and arthroscopic shoulder surgery with implant insertion.

  5. [From the French Society of Plastic and Reconstructive Surgery to the French Society of Plastic Reconstructive and Aesthetic Surgery].

    PubMed

    Glicenstein, J

    2004-04-01

    (The) 3rd December 1952, 11 surgeons and other specialists found the French Society of Plastic and Reconstructive Surgery (SFCPR) which was officially published on (the) 28 September 1953. The first congress was during October 1953 and the first president as Maurice Aubry. The first secretary was Daniel Morel Fatio. The symposiums were after about three of four times each year and the thematic subjects were initially according the reconstructive surgery. The review "Annales de chirurgie plastique" was free in 1956. The members of the Society were about 30 initially, but their plastic surgery in the big hospitals at Paris and other big towns in France. The "specialty" of plastic surgery was created in 1971. On "syndicate", one French board of plastic reconstructive and aesthetic surgery, the increasing of departments of plastic surgery were the front of increasing of the plastic surgery in French and of the number of the French Society of Plastic Reconstructive surgery (580 in 2003). The French Society organized the International Congress of Plastic Surgery in 1975. The society SFCPR became the French Society of plastic reconstruction and Aesthetic Surgery (SFCPRE) in 1983 and the "logo" (front view) was in the 1994 SOF.CPRE.

  6. Macroeconomic landscape of refractive surgery in the United States.

    PubMed

    Corcoran, Kevin J

    2015-07-01

    This review examines the economic history of refractive surgery and the decline of laser-assisted in-situ keratomileusis (LASIK) in the USA, and the emergence of refractive cataract surgery as an area of growth. Since it peaked in 2007 at 1.4 million procedures per year, LASIK has declined 50% in the USA, whereas refractive cataract surgery, including presbyopia-correcting intraocular lenses (IOLs), astigmatism-correcting IOLs, and femtosecond laser-assisted cataract surgery, has grown to 350 000 procedures per year, beginning in 2003. Patients are price-sensitive and responsive to publicity (good or bad) about refractive surgery and refractive cataract surgery. LASIK's decline has been partially offset by the emergence of refractive cataract surgery. About 11% of all cataract surgery in the USA involves presbyopia-correcting IOLs, astigmatism-correcting IOLs, or a femtosecond laser. From the surgeon's perspective, there are high barriers to entry into the marketplace for refractive surgery and refractive cataract surgery due to the high capital cost of excimer and femtosecond lasers, the high skill level required to deliver spectacular results to demanding patients who pay out of pocket, and the necessity to perform a high volume of surgeries to satisfy both of these requirements. Probably, less than 7% of US cataract surgeons can readily meet all of these requirements.

  7. Does strabismus surgery improve quality and mood, and what factors influence this?

    PubMed

    McBain, H B; MacKenzie, K A; Hancox, J; Ezra, D G; Adams, G G W; Newman, S P

    2016-05-01

    AimsTo establish the impact of adult strabismus surgery on clinical and psychosocial well-being and determine who experiences the greatest benefit from surgery and how one could intervene to improve quality of life post-surgery.MethodsA longitudinal study, with measurements taken pre-surgery and at 3 and 6 months post-surgery. All participants completed the AS-20 a disease specific quality of life scale, along with measures of mood, strabismus and appearance-related beliefs and cognitions and perceived social support. Participants also underwent a full orthoptic assessment at their preoperative visit and again 3 months postoperatively. Clinical outcomes of surgery were classified as success, partial success or failure, using the largest angle of deviation, diplopia and requirement for further therapy.Results210 participants took part in the study. Strabismus surgery led to statistically significant improvements in psychosocial and functional quality of life. Those whose surgery was deemed a partial success did however experience a deterioration in quality of life. A combination of clinical variables, high expectations, and negative beliefs about the illness and appearance pre-surgery were significant predictors of change in quality of life from pre- to post-surgery.ConclusionsStrabismus surgery leads to significant improvements in quality of life up to 6 months postoperatively. There are however a group of patients who do not experience these benefits. A series of clinical and psychosocial factors have now been identified, which will enable clinicians to identify patients who may be vulnerable to poorer outcomes post-surgery and allow for the development of interventions to improve quality of life after surgery.

  8. Psychosocial changes after cosmetic surgery: a 5-year follow-up study.

    PubMed

    von Soest, Tilmann; Kvalem, Ingela L; Skolleborg, Knut C; Roald, Helge E

    2011-09-01

    Most studies examining psychosocial changes after cosmetic surgery have short follow-up periods and therefore provide limited information about long-term effects of such surgery. Moreover, studies that identify whether preexisting patient characteristics are associated with poor psychosocial outcomes after cosmetic surgery are lacking. The current study provides information about both of these issues. Questionnaire data from 130 female Norwegian cosmetic surgery patients were obtained before and 5 years after surgery. The questionnaire consisted of measures on appearance satisfaction, self-esteem, psychological problems, and patients' evaluation of the outcome of surgery. Data from a representative sample of 838 Norwegian women, aged 22 to 55 years, were used for comparison purposes. Analyses revealed an improvement in both general appearance satisfaction and satisfaction with the body part operated on 5 years after surgery. A small increase in self-esteem was observed as well. High rates of preoperative psychological problems and low self-esteem were related to more negative changes in some of the psychosocial measures after surgery compared with patients with better psychological health. Furthermore, factors associated with the actual decision to undergo surgery were related to changes in psychological health and patients' evaluation of the outcome of surgery. This study indicates that cosmetic surgery has positive long-term effects on appearance-related variables. However, surgeons should be particularly aware of patients with psychological problems, as these may compromise patient satisfaction with the effects of cosmetic surgery. Factors affecting the decision itself to undergo cosmetic surgery may also be relevant for subsequent psychosocial outcomes. Therapeutic, II.

  9. Key textbooks in the development of modern american plastic surgery: the first half of the twentieth century.

    PubMed

    Haddock, Nicholas T; McCarthy, Joseph G

    2013-07-01

    A number of historical texts published during the first half of the twentieth century played a pivotal role in shaping and defining modern plastic surgery in the United States. Blair's Surgery and Diseases of the Mouth and Jaws (1912), John Staige Davis's Plastic Surgery: Its Principles and Practice (1919), Gillies's Plastic Surgery of the Face (1920), Fomon's Surgery of Injury and Plastic Repair (1939), Ivy's Manual of Standard Practice of Plastic and Maxillofacial Surgery, Military Surgery Manuals (1943), Padgett and Stephenson's Plastic and Reconstructive Surgery (1948), and Kazanjian and Converse's The Surgical Treatment of Facial Injuries (1949) were reviewed. These texts were published at a time when plastic surgery was developing as a distinct specialty. Each work represents a different point in this evolution. All were not inclusive of all of plastic surgery, but all had a lasting impact. Four texts were based on clinical experience from World War I; one included experience from World War II; and two included experience from both. One text became a military surgical handbook in World Wars I and II, playing an important role in care for the wounded. History has demonstrated that times of war spark medical/surgical advancements, and these wars had a dramatic impact on the development of reconstructive plastic surgery. Each of these texts documented surgical advancements and provided an intellectual platform that helped shape and create the independent discipline of plastic surgery during peacetime. For many future leaders of plastic surgery, these books served as their introduction to this new field.

  10. Assessment of the effect of off-pump coronary artery bypass (OPCAB) surgery on right ventricle function using strain and strain rate imaging.

    PubMed

    Khani, Mohammad; Hosseintash, Mahsa; Foroughi, Mahnoosh; Naderian, Mohammadreza; Khaheshi, Isa

    2016-04-01

    Right ventricle function significantly decreases after coronary artery bypass surgery; as one of the likely causes, such a condition is attributed to the use of cardiopulmonary pump (CPB). Because nowadays there is a tendency toward increasing use of off-pump coronary artery bypass (OPCAB) surgery, this study was conducted to evaluate the right ventricle function after this type of surgery using strain and strain rate imaging (SRI) echocardiography. This study was conducted on 30 patients, candidate for elective OPCAB surgery, between 2011 and 2012. Standard echocardiography was performed before the surgery and the right ventricle function was examined using strain and SRI echocardiography. Then patient underwent surgery, 6 days and 3 months after surgery they underwent echocardiography again and the results obtained from the three stages were compared with each other. Participants included 30 patients (23 males and 7 females) with a mean age of 66±11 years. Compared to the prior of the surgery, 6 days and 3 months after the surgery there was a significant decrease in tricuspid annular plane systolic excursion (TAPSE), tissue Doppler imaging (TDI) at the lateral annulus of tricuspid valve, and strain and SRI of right ventricle. However, the values obtained 3 months after surgery were significantly higher than those obtained after 6 days. In other words, the right ventricle function 6 days after the surgery had dropped, however some of the values recovered 3 months after the surgery. The findings of this study are consistent with other studies in this field and showed that after coronary artery surgery a decline occurs in right ventricular function. However, more detailed quantitative strain and SRI parameters which were measured in our study showed that at the early days after the OPCAB surgery there is a decline in the right ventricle function which is relatively reversible at longer intervals (3 months after surgery).

  11. 0 + 5 Vascular Surgery Residents' Operative Experience in General Surgery: An Analysis of Operative Logs from 12 Integrated Programs.

    PubMed

    Smith, Brigitte K; Kang, P Chulhi; McAninch, Chris; Leverson, Glen; Sullivan, Sarah; Mitchell, Erica L

    2016-01-01

    Integrated (0 + 5) vascular surgery (VS) residency programs must include 24 months of training in core general surgery. The Accreditation Council for Graduate Medical Education currently does not require specific case numbers in general surgery for 0 + 5 trainees; however, program directors have structured this time to optimize operative experience. The aim of this study is to determine the case volume and type of cases that VS residents are exposed to during their core surgery training. Accreditation council for graduate medical education operative logs for current 0 + 5 VS residents were obtained and retrospectively reviewed to determine general surgery case volume and distribution between open and laparoscopic cases performed. Standard statistical methods were applied. A total of 12 integrated VS residency programs provided operative case logs for current residents. A total of 41 integrated VS residents in clinical years 2 through 5. During the postgraduate year-1 training year, residents participated in significantly more open than laparoscopic general surgery cases (p < 0.0001). This difference was consistent over the first 3 years of training. The most frequently logged open general surgery cases are hernia repair (20%), skin and soft tissue (7.4%), and breast (6.3%). Residents in programs with core surgery over 3 years participated in significantly more general surgery operations compared with residents in programs with core surgery spread out over 4 years (p = 0.035). 0 + 5 VS residents perform significantly more open operations than laparoscopic operations during their core surgery training. The majority of these operations are minor, nonabdominal procedures. The 0 + 5 VS residency program general surgery operative training requirements should be reevaluated and case minimums defined. The general surgery training component of 0 + 5 VS residencies may need to be restructured to meet the needs of current and future trainees. Copyright © 2016 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  12. [Office surgery: organization, legislative, and medico-legal problems. Personal experience].

    PubMed

    Pepe, N; Actis Dato, G M; Vennarecci, G; Anselmo, A

    1993-11-01

    The authors approach the subject of office surgery by underlining the advantages of this procedure. In particular, they focus attention on the anesthesiological and legislative problems. Depending on the setting used for surgery and the duration of hospitalisation, ambulatorial surgery can be divided into: day-hospital, office surgery, one-day surgery, short-stay surgery, same-day surgery, The authors report their own experience relating to 103 cases with relative complications. A total of 103 operations of medium-to- major ambulatorial surgery were performed (100 females and 3 males, mean age 36.8). One week prior to surgery all patients attended a medical out-patient examination in order to fill in medical records and be prescribed routine hematochemical tests, chest X-ray and ECG. The preoperative anesthesiological evaluation was made at the time of surgery. All patients received antibiotic prophylactic treatment. Postoperative complications were reported above all following neuroleptoanalgesia and amounted to a total of 5 cases: nausea (4 cases) associated with vomit (1 case), and postural hypotension (1 case). No infective complications were observed. The authors emphasise the importance of a careful preoperative selection of patients; an out-patient structure equipped with the appropriate instrument and machinery for surgery and the constant presence of anesthetists to ensure correct anesthesia (local, neuroleptoanalgesic, peridural general), reanimation and postoperative care. The aims of ambulatorial surgery are, in broad terms, the safety of procedures, convenience for the patient and organisational and economic savings for health structures. Ambulatorial surgery has an extremely high acceptance rate by patients. Lastly, the authors also report the juridical and bureaucratic problems faced by ambulatorial surgery and look forward to its wider diffusion. In the future office surgery might represent an important contribution to surgical therapeutic strategies, allowing, if well organised, an excellent compromise between safety, convenience and reduced costs for the patient.

  13. Laparoscopic Adjustable Gastric Banding Revisions in Singapore: a 10-Year Experience.

    PubMed

    Ngiam, Kee Yuan; Khoo, Valerie Yu Hui; Kong, Lucy; Cheng, Anton Kui Sing

    2016-05-01

    Bariatric surgery is increasingly being carried out and revisional procedures have also risen in concert. A review of the complications and revisions might elucidate technical and patient factors that influence the outcomes of bariatric surgeries in Asian patients. The objective of this study is to review the safety and efficacy of revisional bariatric surgery in a single center in Singapore over a 10-year period. The setting of this study is a single public hospital with a multidisciplinary bariatric service including a weight management center, specialized endocrinology services, and bariatric surgical team. Participants were selected for surgery based on body mass index (BMI) and comorbidities. All patients underwent primary laparoscopic adjustable gastric banding (LAGB). Patients were then analyzed according to the types of revisional surgeries. The primary outcome was the type of complications and revisional surgeries. Secondary outcomes include short-term excess weight loss and further complications. A total of 365 patients were analyzed. 9.6% had a secondary procedure. In particular, two groups of complications required revisional surgery: failure of sustained weight loss and complications related to the LAGB insertion and use. Revisional surgeries had equivalent major complication rates (5.7%) compared to primary bariatric surgeries (6.8%). Revisional surgeries such as revisional LAGB (4.9 ± 9.8 kg), laparoscopic sleeve gastrectomy (LSG; 6.9 ± 21.0 kg), Roux-en-Y gastric bypass (RYGB; 4.6 ± 13.0 kg), and bilio-pancreatic diversion (BPD; 3.5 ± 6.3 kg) had modest weight loss compared to primary weight loss (12.7 ± 9.5 kg). Primary LAGB had a greater percentage excess weight loss in the first and second years post-surgery compared to revisional surgeries. There was one mortality post-primary surgery and no post-revisional surgical mortalities. Revisional bariatric surgery for complications related to the primary surgery is safe but had reduced excess weight loss compared to the initial surgery.

  14. Robotic surgery

    MedlinePlus

    Robot-assisted surgery; Robotic-assisted laparoscopic surgery; Laparoscopic surgery with robotic assistance ... computer station and directs the movements of a robot. Small surgical tools are attached to the robot's ...

  15. 21 CFR 878.3925 - Plastic surgery kit and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Plastic surgery kit and accessories. 878.3925... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3925 Plastic surgery kit and accessories. (a) Identification. A plastic surgery kit and accessories is a device intended to...

  16. 21 CFR 878.3925 - Plastic surgery kit and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Plastic surgery kit and accessories. 878.3925... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3925 Plastic surgery kit and accessories. (a) Identification. A plastic surgery kit and accessories is a device intended to...

  17. 21 CFR 878.3925 - Plastic surgery kit and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Plastic surgery kit and accessories. 878.3925... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3925 Plastic surgery kit and accessories. (a) Identification. A plastic surgery kit and accessories is a device intended to...

  18. 21 CFR 878.3925 - Plastic surgery kit and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Plastic surgery kit and accessories. 878.3925... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3925 Plastic surgery kit and accessories. (a) Identification. A plastic surgery kit and accessories is a device intended to...

  19. 21 CFR 878.3925 - Plastic surgery kit and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Plastic surgery kit and accessories. 878.3925... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3925 Plastic surgery kit and accessories. (a) Identification. A plastic surgery kit and accessories is a device intended to...

  20. A Proposal for the Consolidation of Dermatology Services of Walter Reed Army Medical Center and the National Naval Medical Center

    DTIC Science & Technology

    1999-08-01

    This includes the treatment of common skin conditions such as acne, dermatitis, psoriasis, vitiligo or alopecia to the more complex laser surgeries and...Phototherapy, Laser Surgery, Pediatric Dermatology, HIV Dermatology, Patch Testing, MOHS Micrographic Surgery, and Dermatologic Surgery. The entire...Dermatology Service is located on the first floor of the hospital. Minor surgical and MOHS Micrographic Surgery, ultraviolet treatment, and laser surgery

  1. The ongoing emergence of robotics in plastic and reconstructive surgery.

    PubMed

    Struk, S; Qassemyar, Q; Leymarie, N; Honart, J-F; Alkhashnam, H; De Fremicourt, K; Conversano, A; Schaff, J-B; Rimareix, F; Kolb, F; Sarfati, B

    2018-04-01

    Robot-assisted surgery is more and more widely used in urology, general surgery and gynecological surgery. The interest of robotics in plastic and reconstructive surgery, a discipline that operates primarily on surfaces, has yet to be conclusively proved. However, the initial applications of robotic surgery in plastic and reconstructive surgery have been emerging in a number of fields including transoral reconstruction of posterior oropharyngeal defects, nipple-sparing mastectomy with immediate breast reconstruction, microsurgery, muscle harvesting for pelvic reconstruction and coverage of the scalp or the extremities. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  2. Medical students' views on thoracic surgery residency programs in a Japanese medical school.

    PubMed

    Morishita, Kiyofumi; Naraoka, Shu-ichi; Miyajima, Masahiro; Uzuka, Takeshi; Saito, Tatsuya; Abe, Tomio

    2003-09-01

    There has been a decline in the number of medical students applying for thoracic surgery training programs. We obtained knowledge of medical students' views on thoracic surgery residency programs. After completion of thoracic surgery clerkship, 17 students were asked to fill out questionnaires on first-year thoracic surgery residency programs. The majority of students considered thoracic surgery to be held in high regard by the general public, and felt that the salary was sufficient. However, only one student chose a thoracic surgery training program. The main reason for not applying for thoracic surgery residency was lifestyle issues. The factors in determining career choice included quality of education and work hours. Medical students are likely to select specialties other than thoracic surgery. Since the main factor influencing medical students' career is the quality of education in a residency program, efforts should be made to improve the quality of education.

  3. [Impact of digital technology on clinical practices: perspectives from surgery].

    PubMed

    Zhang, Y; Liu, X J

    2016-04-09

    Digital medical technologies or computer aided medical procedures, refer to imaging, 3D reconstruction, virtual design, 3D printing, navigation guided surgery and robotic assisted surgery techniques. These techniques are integrated into conventional surgical procedures to create new clinical protocols that are known as "digital surgical techniques". Conventional health care is characterized by subjective experiences, while digital medical technologies bring quantifiable information, transferable data, repeatable methods and predictable outcomes into clinical practices. Being integrated into clinical practice, digital techniques facilitate surgical care by improving outcomes and reducing risks. Digital techniques are becoming increasingly popular in trauma surgery, orthopedics, neurosurgery, plastic and reconstructive surgery, imaging and anatomic sciences. Robotic assisted surgery is also evolving and being applied in general surgery, cardiovascular surgery and orthopedic surgery. Rapid development of digital medical technologies is changing healthcare and clinical practices. It is therefore important for all clinicians to purposefully adapt to these technologies and improve their clinical outcomes.

  4. Disparities in Aesthetic Procedures Performed by Plastic Surgery Residents.

    PubMed

    Silvestre, Jason; Serletti, Joseph M; Chang, Benjamin

    2017-05-01

    Operative experience in aesthetic surgery is an important issue affecting plastic surgery residents. This study addresses the variability of aesthetic surgery experience during plastic surgery residency. National operative case logs of chief residents in independent/combined and integrated plastic surgery residency programs were analyzed (2011-2015). Fold differences between the bottom and top 10th percentiles of residents were calculated for each aesthetic procedure category and training model. The number of residents not achieving case minimums was also calculated. Case logs of 818 plastic surgery residents were analyzed. There was marked variability in craniofacial (range, 6.0-15.0), breast (range, 2.4-5.9), trunk/extremity (range, 3.0-16.0), and miscellaneous (range, 2.7-22.0) procedure categories. In 2015, the bottom 10th percentile of integrated and independent/combined residents did not achieve case minimums for botulinum toxin and dermal fillers. Case minimums were achieved for the other aesthetic procedure categories for all graduating years. Significant variability persists for many aesthetic procedure categories during plastic surgery residency training. Greater efforts may be needed to improve the aesthetic surgery experience of plastic surgery residents. © 2016 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com

  5. The Effect of Bariatric Surgery on Diabetic Retinopathy: Good, Bad, or Both?

    PubMed

    Gorman, Dora M; le Roux, Carel W; Docherty, Neil G

    2016-10-01

    Bariatric surgery, initially intended as a weight-loss procedure, is superior to standard lifestyle intervention and pharmacological therapy for type 2 diabetes in obese individuals. Intensive medical management of hyperglycemia is associated with improved microvascular outcomes. Whether or not the reduction in hyperglycemia observed after bariatric surgery translates to improved microvascular outcomes is yet to be determined. There is substantial heterogeneity in the data relating to the impact of bariatric surgery on diabetic retinopathy (DR), the most common microvascular complication of diabetes. This review aims to collate the recent data on retinal outcomes after bariatric surgery. This comprehensive evaluation revealed that the majority of DR cases remain stable after surgery. However, risk of progression of pre-existing DR and the development of new DR is not eliminated by surgery. Instances of regression of DR are also noted. Potential risk factors for deterioration include severity of DR at the time of surgery and the magnitude of glycated hemoglobin reduction. Concerns also exist over the detrimental effects of postprandial hypoglycemia after surgery. In vivo studies evaluating the chronology of DR development and the impact of bariatric surgery could provide clarity on the situation. For now, however, the effect of bariatric surgery on DR remains inconclusive.

  6. Topical anesthesia for transpupillary silicone oil removal combined with cataract surgery.

    PubMed

    Jonas, Jost B; Hugger, Philipp; Sauder, Gangolf

    2005-09-01

    To assess safety of topical anesthesia for transpupillary silicone oil removal in combination with cataract surgery. Department of Ophthalmology Mannheim, University of Heidelberg, Mannheim, Germany. The clinical interventional study included 37 consecutive patients having transpupillary silicone oil removal combined with cataract surgery. Without exception, surgery was carried out in topical anesthesia for all patients. During the study period, there were no patients having transpupillary silicone oil removal in another type of local anesthesia than topical anesthesia. Topical anesthesia was achieved with oxybuprocaine 0.4% eyedrops installed 4 to 5 times prior to surgery. Cataract surgery was performed using the clear cornea technique with implantation of a foldable intraocular posterior chamber lens. Silicone oil was released through a planned posterior capsulotomy during cataract surgery prior to implantation of the intraocular lens (IOL). For all patients, surgery could be carried out in topical anesthesia without switching to peribulbar or any other type of anesthesia. None of the patients complained about severe pain intraoperatively or postoperatively. No severe complications such as expulsive hemorrhage, luxation of the IOL, or iris incarceration were encountered in any of the surgeries. Transpupillary silicone oil through a planned posterior capsulotomy during cataract surgery may be performed in topical surgery.

  7. Cosmetic surgery in Australia: a risky business?

    PubMed

    Parker, Rhian

    2007-08-01

    Cosmetic surgery is increasing in popularity in Australia and New Zealand, as it is across other Western countries. However, there is no systematic mechanism for gathering data about cosmetic surgery, nor about the outcomes of that surgery. This column argues that the business of cosmetic surgery in Australia has questionable marketing standards, is conducted with little scrutiny or accountability and offers patients imperfect knowledge about cosmetic procedures. It also argues that while medical practitioners debate among themselves over who should carry out cosmetic procedures, little attention has been paid to questionable advertising in the industry and even less to highlighting the real risks of undergoing cosmetic surgery. While consumers are led to believe that cosmetic surgery is accessible, affordable and safe, they are sheltered from the reality of invasive and risky surgery and from the ability to clearly discern that all cosmetic procedures carry risk. While doctors continue to undertake advertising and engage in a territorial war, they fail to address the really important issues in cosmetic surgery. These are: providing real evidence about what happens in the industry, developing stringent regulations under which the industry should operate and ensuring that all patients considering cosmetic surgery are fully informed as to the risks of that surgery.

  8. Social determinants of cataract surgery utilization in south India. The Operations Research Group.

    PubMed

    Brilliant, G E; Lepkowski, J M; Zurita, B; Thulasiraj, R D

    1991-04-01

    A field trial was conducted to compare the effects of eight health education and economic incentive interventions on the awareness and acceptance of cataract surgery. Cataract screening and follow-up surgery were offered to more than 19,000 residents age 40 years and older in a probability sample of 90 villages in south India. Eight months after intervention, an evaluation was conducted to identify those in need of surgery who had been operated on. Two principal measures of program effectiveness are examined: awareness of cataract surgery and acceptance of the surgery. The type of intervention had a negligible effect on awareness of cataract surgery. A multiple logistic regression analysis revealed that individuals who were aware of surgery tended to be male, literate, and more affluent than those who were unaware of that option. Interventions that covered the complete costs of surgery had higher surgery acceptance rates. One health education strategy, house-to-house visits by a subject with aphakia, increased acceptance of the procedure more than others. In a multiple logistic regression analysis of acceptance rates, persons accepting surgery tended to be male; other factors were not important in explaining variation in acceptance rates.

  9. Effect of Endovascular Interventions on General Surgery Trainee Operative Experience; a Comparison of Case Log Reports.

    PubMed

    Pedersen, Rose C; Li, Yiping; Chang, Jason S; Lew, Wesley K; Patel, Kaushal Kevin

    2016-05-01

    Vascular surgery fellowship training has evolved with the widespread adoption of endovascular interventions. The purpose of this study is to examine how general surgery trainee exposure to vascular surgery has changed over time. Review of the Accreditation Council for Graduate Medical Education national case log reports for graduating Vascular Surgery Fellows (VF), and general surgery residents (GSR) from 2001 to 2012 was performed. The number of GSR increased from 1021 to 1098, and the number of VF increased from 96 to 121 from 2001 to 2012. The total number of vascular cases done by VF increased by 1161 since 2001 (298-762), whereas the total number of vascular cases done by GSR has decreased by 40% during this time period (186-116). Vascular fellows increase was due primarily to an increase in endovascular experience; a finding not noted in general surgery residents. Vascular fellow case log changes are due primarily to an increase in endovascular experience that has not been mirrored by general surgery trainees. Open surgery experience has decreased overall for general surgery residents in all major categories, a change not seen in vascular surgery fellows. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Surgical specialty procedures in rural surgery practices: implications for rural surgery training.

    PubMed

    Sticca, Robert P; Mullin, Brady C; Harris, Joel D; Hosford, Clint C

    2012-12-01

    Specialty procedures constitute one eighth of rural surgery practice. Currently, general surgeons intending to practice in rural hospitals may not get adequate training for specialty procedures, which they will be expected to perform. Better definition of these procedures will help guide rural surgery training. Current Procedural Terminology codes for all surgical procedures for 81% of North Dakota and South Dakota rural surgeons were entered into the Dakota Database for Rural Surgery. Specialty procedures were analyzed and compared with the Surgical Council on Resident Education curriculum to determine whether general surgery training is adequate preparation for rural surgery practice. The Dakota Database for Rural Surgery included 46,052 procedures, of which 5,666 (12.3%) were specialty procedures. Highest volume specialty categories included vascular, obstetrics and gynecology, orthopedics, cardiothoracic, urology, and otolaryngology. Common procedures in cardiothoracic and vascular surgery are taught in general surgical residency, while common procedures in obstetrics and gynecology, orthopedics, urology, and otolaryngology are usually not taught in general surgery training. Optimal training for rural surgery practice should include experience in specialty procedures in obstetrics and gynecology, orthopedics, urology, and otolaryngology. Copyright © 2012 Elsevier Inc. All rights reserved.

  11. Distinct Disease and Functional Characteristics of Thyroid Surgery-Related Vocal Fold Palsy.

    PubMed

    Tseng, Wen-Chun; Pei, Yu-Cheng; Wong, Alice M K; Li, Hsueh-Yu; Fang, Tuan-Jen

    2016-07-01

    Iatrogenic trauma induced by thyroid surgery is the most common etiology of unilateral vocal fold paralysis (UVFP). UVFP after thyroid surgery may lead to profound physical and psychosocial distress. This study comprehensively evaluated UVFP caused by thyroid surgery, and compared the results with those caused by other surgical trauma. Patients with surgery-related UVFP were evaluated using quantitative laryngeal electromyography, videolaryngostroboscopy, voice acoustic analysis, the Voice Outcome Survey, and the Short Form-36 Health Survey quality-of-life questionnaire. Patients with thyroid surgery and other surgeries were compared. A total of 105 patients were recruited, of whom 52 and 53 were assigned to the thyroid surgery and the other surgery group, respectively. Patients in the thyroid surgery group had a higher proportion of external branch of superior laryngeal nerve (eSLN) involvement, longer duration from disease onset to the first laryngeal electromyography examination, lower jitter, higher harmonic-to-noise ratio, and better quality of life compared with the other surgery group. Specifically for patients in the thyroid surgery group, those with eSLN involvement tended to have more pronounced impairment in jitter and shimmer compared with patients without eSLN involvement. UVFP caused by thyroid surgery has a distinct clinical presentation with relatively high involvement in the eSLN, better voice acoustics, longer waiting time before asking for evaluation, and less impact on quality of life. The involvement of eSLN in these patients further impaired their voice. Early referral is suggested for these patients, especially with suspected eSLN injury.

  12. A PROSPECTIVE STUDY OF CHRONIC PAIN AFTER THORACIC SURGERY

    PubMed Central

    Bayman, Emine Ozgur; Parekh, Kalpaj R.; Keech, John; Selte, Atakan; Brennan, Timothy J.

    2017-01-01

    Background The goal of this study was to detect the predictors of chronic pain at 6 months after thoracic surgery from a comprehensive evaluation of demographic, psychosocial, and surgical factors. Methods Thoracic surgery patients were enrolled 1 week before surgery and followed-up 6 months post-surgery in this prospective, observational study. Comprehensive psychosocial measurements were assessed before surgery. The presence and severity of pain was assessed at 3 and 6 months after surgery. One-hundred seven patients were assessed during the first 3 days after surgery and 99 (30 thoracotomy and 69 video-assisted thoracoscopic surgery, thoracoscopy) patients completed the 6 months follow-up. Patients with vs without chronic pain related to thoracic surgery at 6 months were compared. Results Both incidence (p = 0.37) and severity (p = 0.97) of surgery-related chronic pain at 6 months were similar after thoracotomy (33%, 95% confidence interval [CI]: 17% to 53%, 3.3 ± 2.1) and thoracoscopy (25%, 95% CI: 15% to 36%, 3.3 ± 1.7). Both frequentist and Bayesian multivariate models revealed that severity of acute pain (numerical rating scale, 0–10) is the measure associated with chronic pain related to thoracic surgery. Psychosocial factors and quantitative sensory testing were not predictive. Conclusions There was no difference in the incidence and severity of chronic pain at 6 months in patients undergoing thoracotomy versus thoracoscopy. Unlike other post-surgical pain conditions, none of the pre-operative psychosocial measurements were associated with chronic pain after thoracic surgery. PMID:28248713

  13. Postoperative course of Crohn disease according to timing of bowel resection: Results from the CONNECT Study.

    PubMed

    Lee, Ji Min; Lee, Kang-Moon; Kim, Joo Sung; Kim, You Sun; Cheon, Jae Hee; Ye, Byong Duk; Kim, Young-Ho; Han, Dong Soo; Lee, Chang Kyun; Park, Hyun-Ju

    2018-04-01

    Previous studies have demonstrated that early surgery in Crohn disease (CD) can result in a better clinical course than late surgery. The aim of this study was to compare the clinical course of CD following bowel resection performed at the time of diagnosis (early surgery) and during the course of the disease (late surgery).We reviewed medical records from a hospital-based cohort database that includes Korean CD patients diagnosed before 2009. Patients who underwent bowel resection were included. Age, sex, disease phenotype, time of surgery, medication history including use of corticosteroids, immunomodulators, and biologics, and further surgical history were assessed.In all, 243 CD patients who had undergone bowel resection were included, and 120 patients underwent surgery at the time of diagnosis, while 123 underwent surgery after diagnosis (median 105 months, range 2-277). The use of biologics was significantly higher in the late surgery group than in the early surgery group (P = .020). The use of immunomodulators and reoperation rates did not differ between the groups. Early surgery was associated with less use of biologics (Kaplan-Meier curve analysis P = .015). Multivariate analysis indicated that early surgery and old age at surgery were independent variables associated with less use of biologics.CD patients who underwent bowel resection at the time of diagnosis have a more favorable disease course, represented by less use of biologics. Early surgery might be a treatment option in a subset of CD patients.

  14. Perceived realism and Twitter use are associated with increased acceptance of cosmetic surgery among those watching reality television cosmetic surgery programs.

    PubMed

    Fogel, Joshua; King, Kahlil

    2014-08-01

    Reality television programming is a popular type of television programming, and features shows about cosmetic surgery. Social media such as Facebook and Twitter are increasingly popular methods of sharing information. The authors surveyed college students to determine among those watching reality television cosmetic surgery programs whether perceived realism or social media use was associated with attitudes toward cosmetic surgery. Participants (n=126) were surveyed about their reality television cosmetic surgery program viewing habits, their perception of the realism of reality television programming, and social media topics of Twitter and Facebook. Outcome variables were the Acceptance of Cosmetic Surgery Scales of social, intrapersonal, and consider. Perceived realism was significantly associated with increased scores on the Acceptance of Cosmetic Surgery Scale subscales of social (p=0.004), intrapersonal (p=0.03), and consider (p=0.03). Following a character from a reality television program on Twitter was significantly associated with increased social scores (p=0.04). There was no significant association of Facebook behavior with attitudes toward cosmetic surgery. Cosmetic plastic surgeons may benefit by advertising their services on cosmetic surgery reality television programs. These reality television programs portray cosmetic surgery in a positive manner, and viewers with increased perceived realism will be a potential receptive audience toward such advertising. Also, advertising cosmetic surgery services on Twitter feeds that discuss cosmetic surgery reality television programs would be potentially beneficial.

  15. A comparison of trends in operative approach and postoperative outcomes for colorectal cancer surgery.

    PubMed

    Addae, Jamin K; Gani, Faiz; Fang, Sandy Y; Wick, Elizabeth C; Althumairi, Azah A; Efron, Jonathan E; Canner, Joseph K; Euhus, David M; Schneider, Eric B

    2017-02-01

    Data-assessing trends and perioperative outcomes relative to surgical approach for colorectal cancer (CRC) surgery are lacking. We report national trends of CRC surgery and compare postoperative outcomes by surgical approach. A total of 261,886 patients undergoing surgery for CRC were identified using the Nationwide Inpatient Sample from 2009 to 2012. Trends in surgical approach were assessed using the Cochrane-Armitage test of trends. Multivariable logistic and linear regression analyses were performed to compare length of stay (LOS), postoperative complications, and cost by surgical approach. At the time of surgery, 57.5% underwent an open procedure, whereas 42.4% underwent either a laparoscopic (39.9%) or robotic (2.5%) colorectal surgery. The use of minimally invasive surgery increased over time (2009 versus 2012: 37.3% versus 46.8%; P < 0.001). Postoperative morbidity was 15.9% and was higher after open surgery (open versus laparoscopic versus robotic: 18.4% versus 12.4% versus 13.3%; P < 0.001). Patients who underwent a minimally invasive surgery had shorter LOS (laparoscopic: OR, 0.55, 95% CI, 0.52-0.58; robotic: OR, 0.58; 95% CI, 0.49-0.69; both P < 0.001). Robotic surgery was consistently associated with the highest mean costs followed by laparoscopic and open surgery (P < 0.001). Patients undergoing minimally invasive colorectal surgery had a lower postoperative morbidity and shorter LOS compared with patients undergoing open colorectal surgery. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Review of Robotic Surgery in Gynecology—The Future Is Here

    PubMed Central

    Lauterbach, Roy; Matanes, Emad; Lowenstein, Lior

    2017-01-01

    The authors present a systematic review of randomized and observational, retrospective and prospective studies to compare between robotic surgery as opposed to laparoscopic, abdominal, and vaginal surgery for the treatment of both benign and malignant gynecologic indications. The comparison focuses on operative times, surgical outcomes, and surgical complications associated with the various surgical techniques. PubMed was the main search engine utilized in search of study data. The review included studies of various designs that included at least 25 women who had undergone robotic gynecologic surgery. Fifty-five studies (42 comparative and 13 non-comparative) met eligibility criteria. After careful analysis, we found that robotic surgery was consistently connected to shorter post-surgical hospitalization when compared to open surgery, a difference less significant when compared to laparoscopic surgery. Also, it seems that robotic surgery is highly feasible in gynecology. There are quite a few inconsistencies regarding operative times and estimated blood loss between the different approaches, though in the majority of studies estimated blood loss was lower in the robotic surgery group. The high variance in operative times resulted from the difference in surgeon’s experience. The decision whether robotic surgery should become mainstream in gynecological surgery or remain another surgical technique in the gynecological surgeon’s toolbox requires quite a few more randomized controlled clinical trials. In any case, in order to bring robotic surgery down to the front row of surgery, training surgeons is by far the most important goal for the next few years. PMID:28467761

  17. The Drivers of Academic Success in Cleft and Craniofacial Centers: A 10-Year Analysis of over 2000 Publications.

    PubMed

    Plana, Natalie M; Massie, Jonathan P; Stern, Marleigh J; Alperovich, Michael; Runyan, Christopher M; Staffenberg, David A; Koniaris, Leonidas G; Grayson, Barry H; Diaz-Siso, J Rodrigo; Flores, Roberto L

    2017-02-01

    Cleft and craniofacial centers require significant investment by medical institutions, yet variables contributing to their academic productivity remain unknown. This study characterizes the elements associated with high academic productivity in these centers. The authors analyzed cleft and craniofacial centers accredited by the American Cleft Palate-Craniofacial Association. Variables such as university affiliation; resident training; number of plastic surgery, oral-maxillofacial, and dental faculty; and investment in a craniofacial surgery, craniofacial orthodontics fellowship program, or both, were obtained. Craniofacial and cleft-related research published between July of 2005 and June of 2015 was identified. A stepwise multivariable linear regression analysis was performed to measure outcomes of total publications, summative impact factor, basic science publications, total journals, and National Institutes of Health funding. One hundred sixty centers were identified, comprising 920 active faculty, 34 craniofacial surgery fellowships, and eight craniofacial orthodontic fellowships; 2356 articles were published in 191 journals. Variables most positively associated with a high number of publications were craniofacial surgery and craniofacial orthodontics fellowships (β = 0.608), craniofacial surgery fellowships (β = 0.231), number of plastic surgery faculty (β = 0.213), and university affiliation (β = 0.165). Variables most positively associated with high a number of journals were craniofacial surgery and craniofacial orthodontics fellowships (β = 0.550), university affiliation (β = 0.251), number of plastic surgery faculty (β = 0.230), and craniofacial surgery fellowship (β = 0.218). Variables most positively associated with a high summative impact factor were craniofacial surgery and craniofacial orthodontics fellowships (β = 0.648), craniofacial surgery fellowship (β = 0.208), number of plastic surgery faculty (β = 0.207), and university affiliation (β = 0.116). Variables most positively associated with basic science publications were craniofacial surgery and craniofacial orthodontics fellowships (β = 0.676) and craniofacial surgery fellowship (β = 0.208). The only variable associated with National Institutes of Health funding was craniofacial surgery and craniofacial orthodontics fellowship (β = 0.332). Participation in both craniofacial surgery and orthodontics fellowships demonstrates the strongest association with academic success; craniofacial surgery fellowship, university affiliation, and number of surgeons are also predictive.

  18. The burn surgeon: an endangered species. Can exposure in medical school increase interest in burn surgery?

    PubMed

    Kahn, Steven Alexander; Goldman, Matthew; Daul, Matthew; Lentz, Christopher W

    2011-01-01

    The nation is faced with a shortage of subspecialty physicians, including burn surgeons. Exposure to a specialty in medical school has been shown to influence students' career choices. The authors postulate that exposure to burn surgery increases their interest in the field. Students from a medical school with an American Burn Association-verified burn center and from a school without a burn center were anonymously surveyed and asked to report their interest and knowledge regarding burn surgery using a 5-point Likert scale. They were asked about their current year in school, gender, overall interest in surgery, and any prior exposure to burn surgery (eg, preceptorship or rotation). Students were asked whether exposure to burn surgery or to a strong mentor might increase their interest in the field. Finally, they were asked to pick the most important factor in a list of deterrents to pursuing a career in burn surgery. Predictors of interest in burn surgery were determined with regression analyses. A total of 380 of 662 students responded to the survey (57.4%). Significant predictors of interest in burn surgery were an interest in surgery (P < .001, odds ratio [OR] = 56.3), prior exposure to burn surgery (P = .02, OR = 5.7), and year in school (P = .006, OR = 1.7). First- and second-year students were more likely to report interest in burn surgery (P < .001). Gender and medical school attended were not significant predictors. Prior exposure to burn surgery became a stronger predictor in subgroup analysis of the fourth-year students (P < .001, OR = 24.5). The majority of students reported that exposure to burn surgery (76%) and a strong mentor (87%) would make them more likely to consider burn surgery as a career. "Not interested in surgery" was the most important deterrent to pursuing a career in burn surgery, which was selected by 33% of students. However, 25% of students chose "I don't know anything about burn surgery" as the most important deterrent. Factors specific to burn surgery were less frequently selected (eg, wound care and hot operating room). The majority of students reported ignorance of the field of burns: 64% disagreed that they understood what a burn surgeon does on a daily basis, and 74% agreed they did not know enough about the field to consider it as a career. Exposure to burn surgery in the form of a clinical rotation fosters medical student interest. However, the majority of medical students lack knowledge about the field of burn surgery. Many consider this a deterrent to selecting it as a career. More exposure during medical school and strong mentorship may influence more students to become burn surgeons. Mentorship and recruiting efforts should be focused on students with a general interest in surgery.

  19. Scoliosis surgery - child

    MedlinePlus

    Spinal curvature surgery - child; Kyphoscoliosis surgery - child; Video-assisted thoracoscopic surgery - child; VATS - child ... may also do the procedure using a special video camera. A surgical cut in the back is ...

  20. Impact of bariatric surgery on health care costs of obese persons: a 6-year follow-up of surgical and comparison cohorts using health plan data.

    PubMed

    Weiner, Jonathan P; Goodwin, Suzanne M; Chang, Hsien-Yen; Bolen, Shari D; Richards, Thomas M; Johns, Roger A; Momin, Soyal R; Clark, Jeanne M

    2013-06-01

    Bariatric surgery is a well-documented treatment for obesity, but there are uncertainties about the degree to which such surgery is associated with health care cost reductions that are sustained over time. To provide a comprehensive, multiyear analysis of health care costs by type of procedure within a large cohort of privately insured persons who underwent bariatric surgery compared with a matched nonsurgical cohort. Longitudinal analysis of 2002-2008 claims data comparing a bariatric surgery cohort with a matched nonsurgical cohort. Seven BlueCross BlueShield health insurance plans with a total enrollment of more than 18 million persons. A total of 29 820 plan members who underwent bariatric surgery between January 1, 2002, and December 31, 2008, and a 1:1 matched comparison group of persons not undergoing surgery but with diagnoses closely associated with obesity. Standardized costs (overall and by type of care) and adjusted ratios of the surgical group's costs relative to those of the comparison group. Total costs were greater in the bariatric surgery group during the second and third years following surgery but were similar in the later years. However, the bariatric group's prescription and office visit costs were lower and their inpatient costs were higher. Those undergoing laparoscopic surgery had lower costs in the first few years after surgery, but these differences did not persist. Bariatric surgery does not reduce overall health care costs in the long term. Also, there is no evidence that any one type of surgery is more likely to reduce long-term health care costs. To assess the value of bariatric surgery, future studies should focus on the potential benefit of improved health and well-being of persons undergoing the procedure rather than on cost savings.

  1. Thoracoscopic sympathicotomy in the treatment of palmar hyperhidrosis.

    PubMed

    Bagheri, Reza; Sharifian Attar, Alireza; Haghi, Seyed Ziaollah; Salehi, Maryam; Moradpoor, Rosita

    2016-09-01

    Primary hyperhidrosis interferes with social activities and requires an effective and safe treatment. We aimed to compare the therapeutic outcomes of unilateral single-port sympathicotomy and open surgery. Forty patients with primary palmar hyperhidrosis underwent sympathicotomy; 20 had open surgery, and 20 had video-assisted thoracic surgery. Complete resection of the T1 to T4 ganglia was performed by open surgery, and cutting and cauterization of the sympathetic chain between the T2 and T3 ganglia in the dominant hand was undertaken using video-assisted thoracic surgery. The patients were followed up at 1, 3, 6, and 12 months after surgery. The mean operative times were 39.6 ± 1.46 and 79.8 ± 1.53 min in the video-assisted thoracic surgery and open surgery group, respectively. The mean hospitalization was 2.2 ± 0.41 days after video-assisted thoracic surgery and 3.3 ± 0.47 days after open surgery. Complications included delayed hemothorax, compensatory hyperhidrosis, and wound infection. The mean blood loss during surgery and time to return to work were significantly less in the video-assisted thoracic surgery group. Excessive sweating was completely alleviated in the dominant hand in all patients, and in the opposite hand in 60% and 65% of the video-assisted thoracic surgery and open surgery group, respectively. Single-port sympathicotomy between the T2 and T3 ganglia ipsilateral to the dominant hand is a safe, minimally invasive, and effective treatment for primary palmar hyperhidrosis. Alleviation of excessive sweating in the opposite hand can also be achieved in a large proportion of these patients. © The Author(s) 2016.

  2. Cost-utility analysis of bariatric surgery compared with conventional medical management in Germany: a decision analytic modeling.

    PubMed

    Borisenko, Oleg; Mann, Oliver; Duprée, Anna

    2017-08-03

    The objective was to evaluate cost-utility of bariatric surgery in Germany for a lifetime and 10-year horizon from a health care payer perspective. State-transition Markov model provided absolute and incremental clinical and monetary results. In the model, obese patients could undergo surgery, develop post-surgery complications, experience diabetes type II, cardiovascular diseases or die. German Quality Assurance in Bariatric Surgery Registry and literature sources provided data on clinical effectiveness and safety. The model considered three types of surgeries: gastric bypass, sleeve gastrectomy, and adjustable gastric banding. The model was extensively validated, and deterministic and probabilistic sensitivity analyses were performed to evaluate uncertainty. Cost data were obtained from German sources and presented in 2012 euros (€). Over 10 years, bariatric surgery led to the incremental cost of €2909, generated additional 0.03 years of life and 1.2 quality-adjusted life years (QALYs). Bariatric surgery was cost-effective at 10 years with an incremental cost-effectiveness ratio of €2457 per QALY. Over a lifetime, surgery led to savings of €8522 and generated an increment of 0.7 years of life or 3.2 QALYs. The analysis also depicted an association between surgery and a reduction of obesity-related adverse events (diabetes, cardiovascular disorders). Delaying surgery for up to 3 years, resulted in a reduction of life years and QALYs gained, in addition to a moderate reduction in associated healthcare costs. Bariatric surgery is cost-effective at 10 years post-surgery and may result in a substantial reduction in the financial burden on the healthcare system over the lifetime of the treated individuals. It is also observed that delays in the provision of surgery may lead to a significant loss of clinical benefits.

  3. Impact of cataract surgery in reducing visual impairment: a review.

    PubMed

    Khandekar, Rajiv; Sudhan, Anand; Jain, B K; Deshpande, Madan; Dole, Kuldeep; Shah, Mahul; Shah, Shreya

    2015-01-01

    The aim was to assess the impact of cataract surgeries in reducing visual disabilities and factors influencing it at three institutes of India. A retrospective chart review was performed in 2013. Data of 4 years were collected on gender, age, residence, presenting a vision in each eye, eye that underwent surgery, type of surgery and the amount the patient paid out of pocket for surgery. Visual impairment was categorized as; absolute blindness (no perception of light); blind (<3/60); severe visual impairment (SVI) (<6/60-3/60); moderate visual impairment (6/18-6/60) and; normal vision (≥6/12). Statistically analysis was performed to evaluate the association between visual disabilities and demographics or other possible barriers. The trend of visual impairment over time was also evaluated. We compared the data of 2011 to data available about cataract cases from institutions between 2002 and 2009. There were 108,238 cataract cases (50.6% were female) that underwent cataract surgery at the three institutions. In 2011, 71,615 (66.2%) cases underwent surgery. There were 45,336 (41.9%) with presenting vision < 3/60 and 75,393 (69.7%) had SVI in the fellow eye. Blindness at presentation for cataract surgery was associated to, male patients, Institution 3 (Dristi Netralaya, Dahod) surgeries after 2009, cataract surgeries without Intra ocular lens implant implantation, and patients paying <25 US $ for surgery. Predictors of SVI at time of cataract surgery were, male, Institution 3 (OM), phaco surgeries, those opting to pay 250 US $ for cataract surgeries. Patients with cataract seek eye care in late stages of visual disability. The goal of improving vision related quality of life for cataract patients during the early stages of visual impairment that is common in industrialized countries seems to be non-attainable in the rural India.

  4. [Value of indoleamine 2,3-dioxygenase in diagnosis of systemic inflammatory response syndrome after cardiopulmonary bypass in children with congenital heart disease].

    PubMed

    Wang, Xin; Li, Zong-Xiao; Wen, Yu-Peng; Chang, Cheng

    2018-01-01

    To study the value of indoleamine 2,3-dioxygenase (IDO) in the early diagnosis of systemic inflammatory response syndrome (SIRS) after cardiopulmonary bypass in children with congenital heart disease. A total of 90 children with congenital heart disease who underwent cardiopumonary bypass surgery between May 2012 and January 2016 were enrolled. According to the prsence or absence of SIRS after surgery, they were divided into SIRS group (n=43) and control group (n=47). Peripheral blood samples were collected before surgery, during surgery, and after surgery. Serum levels of IDO, C-reactive protein (CRP), and interleukin-6 (IL-6) were measured and compared between the two groups. The receiver operating characteristic (ROC) curve was used to evaluate their diagnostic efficiency. Compared with the control group, the SIRS group had higher serum CRP levels at 72 hours after surgery, higher IL-6 levels during surgery and at 72 hours after surgery, and higher IDO levels at 24 and 72 hours after surgery. IDO had a certain value in the diagnosis of SIRS at 24 hours after surgery with an area under the ROC curve (AUC) of 0.793, a specificity of 100%, and a sensitivity of 58.14%. CRP, IL-6, and IDO had a certain value in the diagnosis of SIRS at 72 hours after surgery. IDO had the highest diagnostic efficiency with an AUC of 0.927, a specificity of 95.74%, and a sensitivity of 76.74% at 72 hours after surgery. IL-6, CRP, and IDO have a certain value in the diagnosis of SIRS after surgery for congenital heart disease, and IDO has a higher diagnostic efficiency. IDO can predict the development of SIRS in children after surgery for congenital heart disease earlier.

  5. Opening ambulatory surgery centers and stone surgery rates in health care markets.

    PubMed

    Hollingsworth, John M; Krein, Sarah L; Birkmeyer, John D; Ye, Zaojun; Kim, Hyungjin Myra; Zhang, Yun; Hollenbeck, Brent K

    2010-09-01

    Ambulatory surgery centers deliver surgical care more efficiently than hospitals but may increase overall procedure use and adversely affect competing hospitals. Motivated by these concerns we evaluated how opening of an ambulatory surgery center impacts stone surgery use in a health care market and assessed the effect of its opening on the patient mix at nearby hospitals. In a 100% sample of outpatient surgery from Florida we measured annual stone surgery use between 1998 and 2006. We used multiple regression to determine if the rate of change in use differed between markets, defined by the hospital service area, without and with a recently opened ambulatory surgery center. Stone surgery use increased an average of 11 procedures per 100,000 individuals per year (95% CI 1-20, p <0.001) after an ambulatory surgery center opened in a hospital service area. Four years after opening the relative increase in the stone surgery rate was approximately 64% higher (95% CI 27 to 102) in hospital service areas where a center opened vs hospital service areas without a center. These market level increases in surgery were not associated with decreased surgical volume at competing hospitals and the absolute change in patient disease severity treated at nearby hospitals was small. While opening of an ambulatory surgery center did not appear to have an overly detrimental effect on competing hospitals, it led to a significant increase in the population based rate of stone surgery in the hospital service area. Possible explanations are the role of physician financial incentives and unmet surgical demand. 2010 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  6. Review of family-based approaches to improve postoperative outcomes among bariatric surgery patients.

    PubMed

    Vidot, Denise C; Prado, Guillermo; De La Cruz-Munoz, Nestor; Cuesta, Melissa; Spadola, Christine; Messiah, Sarah E

    2015-01-01

    Bariatric surgery must be partnered with postoperative lifestyle modifications for enduring weight loss and related health effects to be fully appreciated. Little is known about how these lifestyle modifications may be affected by the involvement of other family members living in the household; therefore, this review describes current family-based approaches to improving postoperative outcomes in bariatric surgery patients and their families. A MEDLINE search of publications from 1999 to 2014 was conducted in January 2014. Retrieved titles and abstracts were assessed by 2 authors to determine relevance to the topic surrounding family-based approaches to improve postbariatric surgery outcomes. All study designs except case studies were considered if they included some aspect of family as a predictor in relation to improved health outcomes after surgery. Initial searches yielded 650 publications (bariatric surgery+family, n = 193; bariatric surgery+child, n = 338; bariatric surgery+spouse, n = 4; bariatric surgery+social support, n = 115). Two studies met criteria for a family-based approach to improving metabolic outcomes in bariatric patients. Seven studies discussed the impact of bariatric surgery on families. All other studies were excluded for not discussing family-based approaches. Despite limited documentation of family-based approaches on improving health outcomes in patients who underwent bariatric surgery, evidence suggests that such an approach may be advantageous if planned a priori to occur before, during, and after bariatric surgery. Future studies could test the combination of bariatric surgery and a family-based approach for improved metabolic outcomes in both the patient and involved family member(s). Copyright © 2015 American Society for Bariatric Surgery. Published by Elsevier Inc. All rights reserved.

  7. Building a Sustainable Global Surgical Program in an Academic Department of Surgery.

    PubMed

    Zhang, Linda P; Silverberg, Daniel; Divino, Celia M; Marin, Michael

    Global surgery and volunteerism in surgery has gained significant interest in recent years for general surgery residents across the country. However, there are few well-established long-term surgical programs affiliated with academic institutions. The present report discusses the implementation process and challenges facing an academic institution in building a long-term sustainable global surgery program. As one of the pioneer programs in global surgery for residents, the Icahn School of Medicine at Mount Sinai global surgery rotation has been successfully running for the last 10 years in a small public hospital in the Dominican Republic. The present report details many key components of implementing a sustainable global surgery program and the evolution of this program over time. Since 2005, 80 general surgery residents have rotated through Juan Pablo Pina Hospital in the Dominican Republic. They have performed a total of 1239 major operations and 740 minor operations. They have also participated in 328 emergency cases. More importantly, this rotation helped shape residents' sense of social responsibility and ownership in their surgical training. Residents have also contributed to the training of local residents in laparoscopic skills and through cultural exchange. As interest in global surgery grows among general surgery residents, it is essential that supporting academic institutions create sustainable and capacity-building rotations for their residents. These programs must address many of the barriers that can hinder maintenance of a sustainable global surgery experience for residents. After 10 years of sending our residents to the Dominican Republic, we have found that it is possible and valuable to incorporate a formal global surgery rotation into a general surgery residency. Copyright © 2016. Published by Elsevier Inc.

  8. Referral to Cardiac Rehabilitation After Percutaneous Coronary Intervention, Coronary Artery Bypass Surgery, and Valve Surgery: Data From the Clinical Outcomes Assessment Program.

    PubMed

    Beatty, Alexis L; Bradley, Steven M; Maynard, Charles; McCabe, James M

    2017-06-01

    Despite guideline recommendations that patients undergoing percutaneous coronary intervention (PCI), coronary artery bypass surgery, or valve surgery be referred to cardiac rehabilitation, cardiac rehabilitation is underused. The objective of this study was to examine hospital-level variation in cardiac rehabilitation referral after PCI, coronary artery bypass surgery, and valve surgery. We analyzed data from the Clinical Outcomes Assessment Program, a registry of all nonfederal hospitals performing PCI and cardiac surgery in Washington State. We included eligible PCI, coronary artery bypass surgery, and valve surgery patients from 2010 to 2015. We analyzed PCI and cardiac surgery separately by performing multivariable hierarchical logistic regression for the outcome of cardiac rehabilitation referral at discharge, clustered by hospital. Patient-level covariates included age, sex, race/ethnicity, comorbidities, and procedure indication/status. Cardiac rehabilitation referral was reported in 48% (34 047/71 556) of PCI patients and 91% (21 831/23 972) of cardiac surgery patients. The hospital performing the procedure was a stronger predictor of referral than any individual patient characteristic for PCI (hospital referral range 3%-97%; median odds ratio, 5.94; 95% confidence interval, 4.10-9.49) and cardiac surgery (range 54%-100%; median odds ratio, 7.09; 95% confidence interval, 3.79-17.80). Hospitals having an outpatient cardiac rehabilitation program explained only 10% of PCI variation and 0% of cardiac surgery variation. Cardiac rehabilitation referral at discharge was less prevalent after PCI than cardiac surgery. The strongest predictor of cardiac rehabilitation referral was the hospital performing the procedure. Efforts to improve cardiac rehabilitation referral should focus on increasing referral after PCI, especially in low referral hospitals. © 2017 American Heart Association, Inc.

  9. Type of Valvular Heart Disease Requiring Surgery in the 21st Century: Mortality and Length-of-Stay Related to Surgery

    PubMed Central

    Boudoulas, Konstantinos Dean; Ravi, Yazhini; Garcia, Daniel; Saini, Uksha; Sofowora, Gbemiga G.; Gumina, Richard J.; Sai-Sudhakar, Chittoor B.

    2013-01-01

    Aim: While the incidence of rheumatic heart disease has declined dramatically over the last half-century, the number of valve surgeries has not changed. This study was undertaken to define the most common type of valvular heart disease requiring surgery today, and determine in-hospital surgical mortality and length-of-stay (LOS) for isolated aortic or mitral valve surgery in a United States tertiary-care hospital. Methods: Patients with valve surgery between January 2002 to June 2008 at The Ohio State University Medical Center were studied. Patients only with isolated aortic or mitral valve surgery were analyzed. Results: From 915 patients undergoing at least aortic or mitral valve surgery, the majority had concomitant cardiac proce-dures mostly coronary artery bypass grafting (CABG); only 340 patients had isolated aortic (n=204) or mitral (n=136) valve surgery. In-hospital surgical mortality for mitral regurgitation (n=119), aortic stenosis (n=151), aortic insufficiency (n=53) and mitral stenosis (n=17) was 2.5% (replacement 3.4%; repair 1.6%), 3.9%, 5.6% and 5.8%, respectively (p=NS). Median LOS for aortic insufficiency, aortic stenosis, mitral regurgitation, and mitral stenosis was 7, 8, 9 (replacement 11.5; repair 7) and 11 days, respectively (p<0.05 for group). In-hospital surgical mortality for single valve surgery plus CABG was 10.2% (p<0.005 compared to single valve surgery). Conclusions: Aortic stenosis and mitral regurgitation are the most common valvular lesions requiring surgery today. Surgery for isolated aortic or mitral valve disease has low in-hospital mortality with modest LOS. Concomitant CABG with valve surgery increases mortality substantially. Hospital analysis is needed to monitor quality and stimulate improvement among Institutions. PMID:24339838

  10. The effects of cosmetic surgery on body image, self-esteem, and psychological problems.

    PubMed

    von Soest, T; Kvalem, I L; Roald, H E; Skolleborg, K C

    2009-10-01

    This study aims to investigate whether cosmetic surgery has an effect on an individual's body image, general self-esteem, and psychological problems. Further tests were conducted to assess whether the extent of psychological problems before surgery influenced improvements in postoperative psychological outcomes. Questionnaire data from 155 female cosmetic surgery patients from a plastic surgery clinic were obtained before and approximately 6 months after surgery. The questionnaire consisted of measures on body image, self-esteem, and psychological problems. Pre- and postoperative values were compared. Pre- and postoperative measures were also compared with the data compiled from a representative sample of 838 Norwegian women, aged 22-55, with no cosmetic surgery experience. No differences in psychological problems between the presurgery patient and comparison samples were found, whereas differences in body image and self-esteem between the sample groups were reported in an earlier publication. Analyses further revealed an improvement in body image (satisfaction with own appearance) after surgery. A significant but rather small effect on self-esteem was also found, whereas the level of psychological problems did not change after surgery. Postoperative measures of appearance satisfaction, self-esteem, and psychological problems did not differ from values derived from the comparison sample. Finally, few psychological problems before surgery predicted a greater improvement in appearance satisfaction and self-esteem after surgery. The study provides evidence of improvement in satisfaction with own appearance after cosmetic surgery, a variable that is thought to play a central role in understanding the psychology of cosmetic surgery patients. The study also points to the factors that surgeons should be aware of, particularly the role of psychological problems, which could inhibit the positive effects of cosmetic surgery.

  11. Survival After Neoadjuvant and Adjuvant Treatments Compared to Surgery Alone for Resectable Esophageal Carcinoma: A Network Meta-analysis.

    PubMed

    Pasquali, Sandro; Yim, Guang; Vohra, Ravinder S; Mocellin, Simone; Nyanhongo, Donald; Marriott, Paul; Geh, Ju Ian; Griffiths, Ewen A

    2017-03-01

    This network meta-analysis compared overall survival after neoadjuvant or adjuvant chemotherapy (CT), radiotherapy (RT), or combinations of both (chemoradiotherapy, CRT) or surgery alone to identify the most effective approach. The optimal treatment for resectable esophageal cancer is unknown. A search for randomized controlled trials reporting on neoadjuvant and adjuvant therapies was conducted. Using a network meta-analysis, treatments were ranked based on their effectiveness for improving survival. In 33 eligible randomized controlled trials, 6072 patients were randomized to receive either surgery alone (N = 2459) or neoadjuvant CT (N = 1332), RT (N = 58), and CRT (N = 1196) followed by surgery or surgery followed by adjuvant CT (N = 542), RT (N = 383), and CRT (N = 102). Twenty-one comparisons were generated. Neoadjuvant CRT followed by surgery compared with surgery alone was the only treatment to significantly improve survival [hazard ratio (HR) = 0.77, 95% confidence interval (CI): 0.68-0.87]. When trials were grouped considering neoadjuvant and adjuvant therapies and surgery alone, neoadjuvant therapies combined with surgery compared with surgery alone showed a survival advantage (HR = 0.83, 95% CI 0.76-0.90), whereas surgery along with adjuvant therapies showed no significant survival advantage (HR = 0.87, 95% CI 0.67-1.14). A subgroup analysis of neoadjuvant therapies showed a superior effectiveness of neoadjuvant CRT and surgery compared with surgery alone (HR = 0.77, 95% CI 0.68-0.87). This network meta-analysis showed neoadjuvant CRT followed by surgery to be the most effective strategy in improving survival of resectable esophageal cancer. Resources should be focused on developing the most effective neoadjuvant CRT regimens for both adenocarcinomas and squamous cell carcinomas of the esophagus.

  12. Early insulin sensitivity after restrictive bariatric surgery, inconsistency between HOMA-IR and steady-state plasma glucose levels.

    PubMed

    van Dielen, Francois M H; Nijhuis, Jeroen; Rensen, Sander S M; Schaper, Nicolaas C; Wiebolt, Janneke; Koks, Afra; Prakken, Fred J; Buurman, Wim A; Greve, Jan Willem M

    2010-01-01

    The low-grade inflammatory condition present in morbid obesity is thought to play a causative role in the pathophysiology of insulin resistance (IR). Bariatric surgery fails to improve this inflammatory condition during the first months after surgery. Considering the close relation between inflammation and IR, we conducted a study in which insulin sensitivity was measured during the first months after bariatric surgery. Different methods to measure IR shortly after bariatric surgery have given inconsistent data. For example, the Homeostatic Model Assessment of Insulin Resistance (HOMA-IR) levels have been reported to decrease rapidly after bariatric surgery, although clamp techniques have shown sustained insulin resistance. In the present study, we evaluated the use of steady-state plasma glucose (SSPG) levels to assess insulin sensitivity 2 months after bariatric surgery. Insulin sensitivity was measured using HOMA-IR and SSPG levels in 11 subjects before surgery and at 26% excess weight loss (approximately 2 months after restrictive bariatric surgery). The SSPG levels after 26% excess weight loss did not differ from the SSPG levels before surgery (14.3 +/- 5.4 versus 14.4 +/- 2.7 mmol/L). In contrast, the HOMA-IR values had decreased significantly (3.59 +/- 1.99 versus 2.09 +/- 1.02). During the first months after restrictive bariatric surgery, we observed a discrepancy between the HOMA-IR and SSPG levels. In contrast to the HOMA-IR values, the SSPG levels had not improved, which could be explained by the ongoing inflammatory state after bariatric surgery. These results suggest that during the first months after restrictive bariatric surgery, HOMA-IR might not be an adequate marker of insulin sensitivity. Copyright 2010 American Society for Metabolic and Bariatric Surgery. Published by Elsevier Inc. All rights reserved.

  13. Videothoracoscopic surgery before and after chest tube drainage for children with complicated parapneumonic effusion.

    PubMed

    Knebel, Rogerio; Fraga, Jose Carlos; Amantea, Sergio Luis; Isolan, Paola Brolin Santis

    To evaluate the effectiveness of videothoracoscopic surgery in the treatment of complicated parapneumonic pleural effusion and to determine whether there is a difference in the videothoracoscopic surgery outcome before or after the chest tube drainage. The medical records of 79 children (mean age 35 months) undergoing videothoracoscopic surgery from January 2000 to December 2011 were retrospectively reviewed. The same treatment algorithm was used in the management of all patients. Patients were divided into two groups: in group 1, videothoracoscopic surgery was performed as the initial procedure; in group 2, videothoracoscopic surgery was performed after previous chest tube drainage. Videothoracoscopic surgery was effective in 73 children (92.4%); the other six (7.6%) needed another procedure. Sixty patients (75.9%) were submitted directly to videothoracoscopic surgery (group 1) and 19 (24%) primarily underwent chest tube drainage (group 2). Primary videothoracoscopic surgery was associated with a decrease of hospital stay (p=0.05), time to resolution (p=0.024), and time with a chest tube (p<0.001). However, there was no difference between the groups regarding the time until fever resolution, time with a chest tube, and the hospital stay after videothoracoscopic surgery. No differences were observed between groups regarding the need for further surgery and the presence of complications. Videothoracoscopic surgery is a highly effective procedure for treating children with complicated parapneumonic pleural effusion. When videothoracoscopic surgery is indicated in the presence of loculations (stage II or fibrinopurulent), no difference were observed in time of clinical improvement and hospital stay among the patients with or without chest tube drainage before videothoracoscopic surgery. Copyright © 2017 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  14. Characteristics and Correlates of Increasing Use of Surgery in Taiwanese Cancer Patients' Last Month of Life, 2001-2010.

    PubMed

    Liu, Tsang-Wu; Hung, Yen-Ni; Earle, Craig C; Liu, Tsang-Pai; Liu, Li Ni; Tang, Siew Tzuh

    2016-08-01

    Surgery offers the potential to relieve symptoms for patients with cancer at the end of life (EOL) but at significant physiological and economic costs. However, the characteristics and correlates of surgery in last month of life (EOL surgery) of patients with cancer have not been comprehensively explored. This population-based study characterized EOL surgery use and identified its correlates. This retrospective cohort study examined administrative data among 339,546 Taiwanese cancer decedents, 2001 to 2010. We classified procedures according to their likely intent. Approximately 1 in 10 (11.44%, range: 11.08%-11.86%) patients underwent EOL surgery with an increasing utilization over time. The intention for EOL surgery was primarily palliative, followed by cancer-directed, nonmalignancy-directed, and diagnostic. EOL surgery for palliative intent increased whereas other intents decreased significantly over time. EOL surgery was more likely among those who were male, younger, and married; not diagnosed with hepatic-pancreatic or lung cancers; had no comorbidity or documented metastatic codes; and survived less than 1 year from diagnosis. The likelihood of EOL surgery use was higher for patients who received care in a teaching hospital with more acute care hospital beds and higher EOL care intensity. Rates of EOL surgery are lower in Taiwan than those reported in the United States. The increasing use of EOL surgery in Taiwan is primarily for palliative intent. Appropriateness of EOL surgery should be carefully evaluated to avoid underutilizing potentially beneficial, palliative-intent surgery and overutilizing cancer-directed and other surgical procedures, especially for physicians working in hospitals with abundant health care resources and a tendency to treat at-risk patients with cancer aggressively.

  15. Immune function, pain, and psychological stress in patients undergoing spinal surgery.

    PubMed

    Starkweather, Angela R; Witek-Janusek, Linda; Nockels, Russ P; Peterson, Jonna; Mathews, Herbert L

    2006-08-15

    This study was an exploratory repeated measures design comparing patients undergoing two magnitudes of surgery in the lumbar spine: lumbar herniated disc repair and posterior lumbar fusion. The present study evaluated and compared the effect of perceived pain, perceived stress, anxiety, and mood on natural killer cell activity (NKCA) and IL-6 production among adult patients undergoing lumbar surgery. Presurgical stress and anxiety can lead to detrimental patient outcomes after surgery, such as increased infection rates. It has been hypothesized that such outcomes are due to stress-immune alterations, which may be further exacerbated by the extent of surgery. However, psychologic stress, anxiety, and mood have not been previously characterized in patients undergoing spinal surgery. Pain, stress, anxiety, and mood were measured using self-report instruments at T1 (1 week before surgery), T2 (the day of surgery), T3 (the day after surgery), and T4 (6 weeks after surgery). Blood (30 mL) was collected for immune assessments at each time point. Pain, stress, anxiety, and mood state were elevated at baseline in both surgical groups and were associated with significant reduction in NKCA compared with the nonsurgical control group. A further decrease in NKCA was observed 24 hours after surgery in both surgical groups with a significant rise in stimulated IL-6 production, regardless of the magnitude of surgery. In the recovery period, NKCA increased to or above baseline values, which correlated with decreased levels of reported pain, perceived stress, anxiety, and mood state. This study demonstrated that patients undergoing elective spinal surgery are highly stressed and anxious, regardless of the magnitude of surgery and that such psychologic factors may mediate a reduction in NKCA.

  16. Complication and recurrence rate in laser CO2 versus traditional surgery in the treatment of Bartholin's gland cyst.

    PubMed

    Frega, Antonio; Schimberni, Mauro; Ralli, Eleonora; Verrone, Antonella; Manzara, Federica; Schimberni, Matteo; Nobili, Flavia; Caserta, Donatella

    2016-08-01

    The treatment of Bartholin's gland cysts by traditional surgery is characterized by some disadvantages and complications such as hemorrhage, postoperative dyspareunia, infections, necessity for a general anesthesia. Contrarily, CO2 laser surgery might be less invasive and more effective as it solves many problems of traditional surgery. The aim of our study is to describe CO2 laser technique evaluating its feasibility, complication rate and results vs traditional surgery. Among patients treated for Bartholin's gland cyst, we enrolled 62 patients comparing traditional surgical excision vs CO2 laser surgery of whom 27 patients underwent traditional surgery, whereas 35 patients underwent CO2 laser surgery. Mean operative time, complication rate, recurrence rate and short- and long-term outcomes were assessed. The procedures required a mean operative time of 9 ± 5.3 min for CO2 laser surgery and 42.2 ± 13.8 for traditional surgery. Two patients (5.7 %) needed an hemostatic suture for intraoperative bleeding in the laser CO2 laser technique against 14.8 % for traditional surgery. Carbon dioxide allows a complete healing in a mean time of 22 days without scarring, hematomas or wound infections and a return to daily living in a mean time of 2 days. Instead, patients undergone traditional surgery required a mean time of 14 days to return to daily life with a healing mean time completed in 28 days. The minimum rate of intra- and post-operative complications, the ability to perform it under local anesthesia in an outpatient setting make CO2 laser surgery more cost-effective than traditional surgery.

  17. Indication for cataract surgery. Do we have evidence of who will benefit from surgery? A systematic review and meta-analysis.

    PubMed

    Kessel, Line; Andresen, Jens; Erngaard, Ditte; Flesner, Per; Tendal, Britta; Hjortdal, Jesper

    2016-02-01

    The need for cataract surgery is expected to rise dramatically in the future due to the increasing proportion of elderly citizens and increasing demands for optimum visual function. The aim of this study was to provide an evidence-based recommendation for the indication of cataract surgery based on which group of patients are most likely to benefit from surgery. A systematic literature search was performed in the MEDLINE, CINAHL, EMBASE and COCHRANE LIBRARY databases. Studies evaluating the outcome after cataract surgery according to preoperative visual acuity and visual complaints were included in a meta-analysis. We identified eight observational studies comparing outcome after cataract surgery in patients with poor (<20/40) and fair (>20/40) preoperative visual acuity. We could not find any studies that compared outcome after cataract surgery in patients with few or many preoperative visual complaints. A meta-analysis showed that the outcome of cataract surgery, evaluated as objective and subjective visual improvement, was independent on preoperative visual acuity. There is a lack of scientific evidence to guide the clinician in deciding which patients are most likely to benefit from surgery. To overcome this shortage of evidence, many systems have been developed internationally to prioritize patients on waiting lists for cataract surgery, but the Swedish NIKE (Nationell Indikationsmodell för Katarakt Ekstraktion) is the only system where an association to the preoperative scoring of a patient has been related to outcome of cataract surgery. We advise that clinicians are inspired by the NIKE system when they decide which patients to operate to ensure that surgery is only offered to patients who are expected to benefit from cataract surgery. © 2015 The Authors. Acta Ophthalmologica published by John Wiley & Sons Ltd on behalf of Acta Ophthalmologica Scandinavica Foundation.

  18. Incremental direct and indirect cost burden attributed to endometriosis surgeries in the United States.

    PubMed

    Soliman, Ahmed M; Taylor, Hugh S; Bonafede, Machaon; Nelson, James K; Castelli-Haley, Jane

    2017-05-01

    To compare direct and indirect costs between endometriosis patients who underwent endometriosis-related surgery (surgery cohort) and those who have not received surgery (no-surgery cohort). Retrospective cohort study. Not applicable. Endometriosis patients (aged 18-49 years) with (n = 124,530) or without (n = 37,106) a claim for endometriosis-related surgery were identified from the Truven Health MarketScan Commercial and Health and Productivity Management databases for 2006-2014. Not applicable. Primary outcomes were healthcare utilization during 12-month pre- and post-index periods, annual direct (healthcare) and indirect (absenteeism and short- and long-term disability) costs during the 12-month post-index period (in 2014 US dollars). Indirect costs were assessed for patients with available productivity data. Patients in the surgery cohort had significantly higher healthcare resource utilization during the post-index period and had mean annual total adjusted post-index direct costs approximately three times the costs among patients in the no-surgery cohort ($19,203 [SD $7,133] vs. $6,365 [SD $2,364]; average incremental annual direct cost = $12,838). The mean cost of surgery ($7,268 [SD $7,975]) was the single largest contributor to incremental annual direct cost. Mean estimated annual total indirect costs were $8,843 (surgery cohort) vs. $5,603 (no-surgery cohort); average incremental annual indirect cost = $3,240. Endometriosis patients who underwent surgery, compared with endometriosis patients who did not, incurred significantly higher direct costs due to healthcare utilization and indirect costs due to absenteeism or short-term disability. Regardless of the surgery type, the cost of index surgery contributed substantially to the total healthcare expenditure. Copyright © 2017 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  19. [Ambulatory anesthesia in pediatric surgery].

    PubMed

    Ben Khalifa, S; Hila, S; Hamzaoui, M; el Cadhi, A; Jlidi, S; Nouira, F; Hellal, Y; Houissa, T; Chaouachi, B

    2000-04-01

    Child is an ideal patient for day care surgery. So more than 60% of paediatric surgery could benefit by ambulatory surgery. Preoperative visit may select patients for ambulatory surgery. Medical exam may lead to choose pre operative screening. The ideal ambulatory anesthesia is locoregional technic or inhalatory one. Tracheal intubation don't contre indicate ambulatory surgery. Recovery of mental abilities following general anesthesia has not the same significance as in adult. Many studies confirm the safety of paediatric outpatients anesthesia.

  20. Risk of surgical glove perforation in oral and maxillofacial surgery.

    PubMed

    Kuroyanagi, N; Nagao, T; Sakuma, H; Miyachi, H; Ochiai, S; Kimura, Y; Fukano, H; Shimozato, K

    2012-08-01

    Oral and maxillofacial surgery, which involves several sharp instruments and fixation materials, is consistently at a high risk for cross-contamination due to perforated gloves, but it is unclear how often such perforations occur. This study aimed to address this issue. The frequency of the perforation of surgical gloves (n=1436) in 150 oral and maxillofacial surgeries including orthognathic surgery (n=45) was assessed by the hydroinsufflation technique. Orthognathic surgery had the highest perforation rate in at least 1 glove in 1 operation (91.1%), followed by cleft lip and palate surgery (55.0%), excision of oral soft tumour (54.5%) and dental implantation (50.0%). The perforation rate in scrub nurses was 63.4%, followed by 44.4% in surgeons and first assistants, and 16.3% in second assistants. The odds ratio for the perforation rate in orthognathic surgery versus other surgeries was 16.0 (95% confidence interval: 5.3-48.0). The protection rate offered by double gloving in orthognathic surgery was 95.2%. These results suggest that, regardless of the surgical duration and blood loss in all fields of surgery, orthognathic surgery must be categorized in the highest risk group for glove perforation, following gynaecological and open lung surgery, due to the involvement of sharp objects. Copyright © 2012 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  1. Translating weight loss into agency: Men's experiences 5 years after bariatric surgery

    PubMed Central

    Natvik, Eli; Gjengedal, Eva; Moltu, Christian; Råheim, Målfrid

    2015-01-01

    Fewer men than women with severe obesity undergo bariatric surgery for weight loss, and knowledge about men's situation after surgery, beyond medical status, is lacking. Our aim was to explore men's experiences with life after bariatric surgery from a long-term perspective. We conducted in-depth interviews with 13 men, aged 28–60 years, between 5 and 7 years after surgery. The analysis was inspired by Giorgi's phenomenological method. We found that agency was pivotal for how the men understood themselves and their lives after surgery. Weight loss meant regaining opportunities for living and acting in unrestricted and independent daily lives, yet surgery remained a radical treatment with complex consequences. Turning to surgery had involved conceptualizing their own body size as illness, which the men had resisted doing for years. After surgery, the rapid and major weight loss and the feelings of being exhausted, weak, and helpless were intertwined. The profound intensity of the weight loss process took the men by surprise. Embodying weight loss and change involved an inevitable renegotiating of experiences connected to the large body. Having bariatric surgery was a long-term process that seemed unfinished 5 years after surgery. Restrictions and insecurity connected to health and illness persist, despite successful weight loss and embodied change. Bariatric surgery initiated a complex and long-lasting life-changing process, involving both increased capacity for agency and illness-like experiences. PMID:26066518

  2. Pitfalls of implementing acute care surgery.

    PubMed

    Kaplan, Lewis J; Frankel, Heidi; Davis, Kimberly A; Barie, Philip S

    2007-05-01

    Incorporating emergency general surgery into the current practice of the trauma and critical care surgeon carries sweeping implications for future practice and training. Herein, we examine the known benefits of the practice of emergency general surgery, contrast it with the emerging paradigm of acute care surgery, and examine pitfalls already encountered in integration of emergency general surgery into a traditional trauma/critical care surgery service. A MEDLINE literature search was supplemented with local experience and national presentations at major meetings to provide data for this review. Considerations including faculty complement, service structure, resident staffing, physician extenders, the decreased role of community hospitals in providing trauma and emergency general surgery care, and the effects on an elective operative schedule are inadequately explored at present. There are no firm recommendations as to how to incorporate emergency general surgery into a trauma/critical care practice that will satisfy both academic and community practice paradigms. The near future seems likely to embrace the expanded training and clinical care program termed acute care surgery. A host of essential elements have yet to be examined to undertake a critical analysis of the applicability, advisability, and appropriate structure of both emergency general surgery and acute care surgery in the United States. Proceeding along this pathway may be fraught with training, education, and implementation pitfalls that are ideally addressed before deploying acute care surgery as a national standard.

  3. Impact of Nursing Educational Program on Reducing or Preventing Postoperative Complications for Patients after Intracranial Surgery

    ERIC Educational Resources Information Center

    Elmowla, Rasha Ali Ahmed Abd; El-Lateef, Zienab Abd; El-khayat, Roshdy

    2015-01-01

    Intracranial surgery means any surgery performed inside the skull to treat problems in the brain and surrounding structures. Aim: Evaluate the impact of nursing educational program on reducing or preventing postoperative complications for patients after intracranial surgery. Subjects and methods: Sixty adult patients had intracranial surgery (burr…

  4. The omni-relevance of surgery: how medical specialization shapes orthopedic surgeons' treatment recommendations.

    PubMed

    Hudak, Pamela L; Clark, Shannon J; Raymond, Geoffrey

    2013-01-01

    This article examines treatment recommendations in orthopedic surgery consultations and shows how surgery is treated as "omni-relevant" within this activity, providing a context within which the broad range of treatment recommendations proposed by surgeons is offered. Using conversation analysis to analyse audiotaped encounters between orthopedic surgeons and patients, we highlight how surgeons treat surgery as having a special, privileged status relative to other treatment options by (1) invoking surgery (whether or not it is actually being recommended) and (2) presenting surgery as the "last best resort" (in relation to which other treatment options are calibrated, described and considered). This privileged status surfaces in the design and delivery of recommendations as a clear asymmetry: Recommendations for surgery are proposed early, in relatively simple and unmitigated form. In contrast, recommendations not for surgery tend to be delayed and involve significantly more interactional work in their delivery. Possible implications of these findings, including how surgeons' structuring of recommendations may shape patient expectations (whether for surgery or some alternative), and potentially influence the distribution of orthopedic surgery procedures arising from these consultations, are considered.

  5. Selective decontamination of the digestive tract in gastrointestinal surgery: useful in infection prevention? A systematic review.

    PubMed

    Abis, Gabor S A; Stockmann, Hein B A C; van Egmond, Marjolein; Bonjer, Hendrik J; Vandenbroucke-Grauls, Christina M J E; Oosterling, Steven J

    2013-12-01

    Gastrointestinal surgery is associated with a high incidence of infectious complications. Selective decontamination of the digestive tract is an antimicrobial prophylaxis regimen that aims to eradicate gastrointestinal carriage of potentially pathogenic microorganisms and represents an adjunct to regular prophylaxis in surgery. Relevant studies were identified using bibliographic searches of MEDLINE, EMBASE, and the Cochrane database (period from 1970 to November 1, 2012). Only studies investigating selective decontamination of the digestive tract in gastrointestinal surgery were included. Two randomized clinical trials and one retrospective case-control trial showed significant benefit in terms of infectious complications and anastomotic leakage in colorectal surgery. Two randomized controlled trials in esophageal surgery and two randomized clinical trials in gastric surgery reported lower levels of infectious complications. Selective decontamination of the digestive tract reduces infections following esophageal, gastric, and colorectal surgeries and also appears to have beneficial effects on anastomotic leakage in colorectal surgery. We believe these results provide the basis for a large multicenter prospective study to investigate the role of selective decontamination of the digestive tract in colorectal surgery.

  6. [Vitreoretinal outpatient surgery: clinical and financial considerations].

    PubMed

    Creuzot-Garcher, C; Aubé, H; Candé, F; Dupont, G; Guillaubey, A; Malvitte, L; Arnavielle, S; Bron, A

    2008-11-01

    Vitreoretinal surgery has benefited from great advances opening the opportunity for outpatient management. We report on the 6-month experience of outpatient surgery for vitreoretinal diseases. From November 2007 to April 2008, 270 patients benefited from a vitreoretinal surgery, with 173 retinal detachments, 63 epiretinal membranes, and 34 other procedures. Only 8.5% (n=23) of the patients had to stay at the hospital one or two nights. The main reasons were the distance from the hospital and surgery on a single-eye patient. The questionnaire given after the surgery showed that almost all the patients were satisfied with the outpatient setting. In contrast, the financial results showed a loss of income of around 400,000 euros due to the low level of payment of outpatient surgery in France by the national health insurance system. Vitreoretinal surgery can be achieved in outpatient surgery with an improvement in the information given to the patients and the overall organization of the hospitalization. However, the current income provided with vitreoretinal outpatient surgery is highly disadvantageous in France, preventing this method from being generalized.

  7. Prostate Cancer Patients' Refusal of Cancer-Directed Surgery: A Statewide Analysis

    PubMed Central

    Islam, K. M.

    2015-01-01

    Introduction. Prostate cancer is the most common cancer among men in USA. The surgical outcomes of prostate cancer remain inconsistent. Barriers such as socioeconomic factors may play a role in patients' decision of refusing recommended cancer-directed surgery. Methods. The Nebraska Cancer Registry data was used to calculate the proportion of prostate cancer patients recommended the cancer-directed surgery and the surgery refusal rate. Multivariate logistic regression was applied to analyze the socioeconomic indicators that were related to the refusal of surgery. Results. From 1995 to 2012, 14,876 prostate cancer patients were recommended to undergo the cancer-directed surgery in Nebraska, and 576 of them refused the surgery. The overall refusal rate of surgery was 3.9% over the 18 years. Patients with early-stage prostate cancer were more likely to refuse the surgery. Patients who were Black, single, or covered by Medicaid/Medicare had increased odds of refusing the surgery. Conclusion. Socioeconomic factors were related to the refusal of recommended surgical treatment for prostate cancer. Such barriers should be addressed to improve the utilization of surgical treatment and patients' well-being. PMID:25973276

  8. Childbirth after surgery for familial adenomatous polyposis in Japan.

    PubMed

    Kobayashi, Hirotoshi; Ishida, Hideyuki; Ueno, Hideki; Hinoi, Takao; Inoue, Yasuhiro; Ishida, Fumio; Kanemitsu, Yukihide; Konishi, Tsuyoshi; Yamaguchi, Tatsuro; Tomita, Naohiro; Matsubara, Nagahide; Watanabe, Toshiaki; Sugihara, Kenichi

    2017-02-01

    Familial adenomatous polyposis (FAP) is a genetic disorder. Some female patients with FAP can become pregnant. However, the current state of childbirth after surgery for FAP is unclear in Japan. The study investigated 303 patients (147 female) who had undergone surgery for FAP at the 23 institutions between 2000 and 2012. Eighty female patients had information available on childbirth after surgery for FAP. Eight patients (10 %) gave birth after surgery. The mean age at surgery for FAP was 27 (range 20-41) years and 37 years in patients with and without childbirth after surgery, respectively (P = 0.044). The rate of childbirth after surgery was 17 % in women ≤30 years of age and 13 % in those ≤40 years of age. Although only one patient with invasive cancer (2.9 %) gave childbirth after surgery, seven patients without cancer (15.6 %) gave birth (P = 0.045). This study clarified the current state of childbirth after surgery for FAP in Japan. It is important to use these data to determine the best therapeutic approach for female FAP patients.

  9. Focused Ultrasound Surgery for Uterine Fibroids

    MedlinePlus

    ... ultrasound surgery, your doctor may perform a pelvic magnetic resonance imaging (MRI) scan before treatment. Focused ultrasound surgery — also called magnetic resonance-guided focused ultrasound surgery or focused ultrasound ...

  10. Outpatient Surgery

    MedlinePlus

    Skip to content Menu Anesthesia 101 Pain Management Preparing for Surgery Stories Resources About Policymakers Media ASA Member Toolkit Preparation Outpatient Surgery Explore this page: Outpatient Surgery What types of anesthesia are available? How ...

  11. Strabismus

    MedlinePlus

    ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Academy Publications EyeNet Ophthalmology ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Find an Ophthalmologist Advanced ...

  12. Nystagmus

    MedlinePlus

    ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Academy Publications EyeNet Ophthalmology ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Find an Ophthalmologist Advanced ...

  13. Uveitis

    MedlinePlus

    ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Academy Publications EyeNet Ophthalmology ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Find an Ophthalmologist Advanced ...

  14. Retinoblastoma

    MedlinePlus

    ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Academy Publications EyeNet Ophthalmology ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Find an Ophthalmologist Advanced ...

  15. Pediatric heart surgery - discharge

    MedlinePlus

    ... of the aorta repair - discharge; Heart surgery for children - discharge; Atrial septal defect repair - discharge; Ventricular septal ... discharge; Acquired heart disease - discharge; Heart valve surgery - ... Heart surgery - pediatric - discharge; Heart transplant - pediatric - ...

  16. Mohs micrographic surgery

    MedlinePlus

    Skin cancer - Mohs surgery; Basal cell skin cancer - Mohs surgery; Squamous cell skin cancer - Mohs surgery ... visits. During the procedure, the surgeon removes the cancer in layers until all the cancer has been ...

  17. Hirschsprung Disease

    MedlinePlus

    ... does a pull-through procedure soon after diagnosis. Ostomy Surgery Ostomy surgery is a surgical procedure that ... Most children eventually have normal bowel movements. After Ostomy Surgery Infants will feel better after ostomy surgery ...

  18. Robotics in urologic oncology.

    PubMed

    Jain, Saurabh; Gautam, Gagan

    2015-01-01

    Robotic surgery was initially developed to overcome problems faced during conventional laparoscopic surgeries and to perform telesurgery at distant locations. It has now established itself as the epitome of minimally invasive surgery (MIS). It is one of the most significant advances in MIS in recent years and is considered by many as a revolutionary technology, capable of influencing the future of surgery. After its introduction to urology, robotic surgery has redefined the management of urological malignancies. It promises to make difficult urological surgeries easier, safer and more acceptable to both the surgeon and the patient. Robotic surgery is slowly, but surely establishing itself in India. In this article, we provide an overview of the advantages, disadvantages, current status, and future applications of robotic surgery for urologic cancers in the context of the Indian scenario.

  19. “A journey around the world”: Parent narratives of the journey to pediatric resective epilepsy surgery and beyond

    PubMed Central

    Baca, Christine B.; Pieters, Huibrie C.; Iwaki, Tomoko J.; Mathern, Gary W.; Vickrey, Barbara G.

    2015-01-01

    OBJECTIVE Although shorter time to pediatric resective epilepsy surgery is strongly associated with greater disease severity, other non-clinical diagnostic and sociodemographic factors also play a role. We aimed to examine parent-reported barriers to timely receipt of pediatric epilepsy surgery. METHODS We conducted 37 interviews of parents of children who previously had resective epilepsy surgery at UCLA (2006–2011). Interviews were audio-recorded, transcribed and systematically coded using thematic analysis by two independent coders and subsequently checked for agreement. Clinical data, including `time to surgery' (age of epilepsy onset to surgery) were abstracted from medical records. RESULTS The mean time to surgery was 5.3 years (SD=3.8); surgery types included 32% hemispherectomy, 43% lobar/focal, 24% multilobar. At surgery, parents were on average 38.4 years (SD=6.6) and children were 8.2 years (SD=4.7). The more arduous and longer aspect of the journey to surgery was perceived by parents to be experienced prior to presurgical referral. The time from second anti-epileptic drug failure to presurgical referral was ≥1 year in 64% of children. Thematic analysis revealed four themes (with subthemes) along the journey to surgery and beyond: (1) recognition: “something is wrong” (unfamiliarity with epilepsy, identification of medical emergency), (2) searching and finding: “a circuitous journey” (information seeking, finding the right doctors, multiple medications, insurance obstacles, parental stress), (3) surgery is a viable option: “the right spot” (surgery as last resort, surgery as best option, hoping for candidacy), and (4) life now: “we took the steps we needed to” (a new life, giving back). SIGNIFICANCE Multi-pronged interventions targeting parent-, provider- and system-based barriers should focus on the critical presurgical referral period; such interventions are needed to remediate delays and improve access to subspecialty care for children with medically refractory epilepsy and potentially eligible for surgery. PMID:25894906

  20. Veterans Affairs general surgery service: the last bastion of integrated specialty care.

    PubMed

    Poteet, Stephen; Tarpley, Margaret; Tarpley, John L; Pearson, A Scott

    2011-11-01

    In a time of increasing specialization, academic training institutions provide a compartmentalized learning environment that often does not reflect the broad clinical experience of general surgery practice. This study aimed to evaluate the contribution of the Veterans Affairs (VA) general surgery surgical experience to both index Accreditation Council for Graduate Medical Education (ACGME) requirements and as a unique integrated model in which residents provide concurrent care of multiple specialty patients. Institutional review board approval was obtained for retrospective analysis of electronic medical records involving all surgical cases performed by the general surgery service from 2005 to 2009 at the Nashville VA. Over a 5-year span general surgery residents spent an average of 5 months on the VA general surgery service, which includes a postgraduate year (PGY)-5, PGY-3, and 2 PGY-1 residents. Surgeries involved the following specialties: surgical oncology, endocrine, colorectal, hepatobiliary, transplant, gastrointestinal laparoscopy, and elective and emergency general surgery. The surgeries were categorized according to ACGME index requirements. A total of 2,956 surgeries were performed during the 5-year period from 2005 through 2009. Residents participated in an average of 246 surgeries during their experience at the VA; approximately 50 cases are completed during the chief year. On the VA surgery service alone, 100% of the ACGME requirement was met for the following categories: endocrine (8 cases); skin, soft tissue, and breast (33 cases); alimentary tract (78 cases); and abdominal (88 cases). Approximately 50% of the ACGME requirement was met for liver, pancreas, and basic laparoscopic categories. The VA hospital provides an authentic, broad-based, general surgery training experience that integrates complex surgical patients simultaneously. Opportunities for this level of comprehensive care are decreasing or absent in many general surgery training programs. The increasing level of responsibility and simultaneous care of multiple specialty patients through the VA hospital systems offers a crucial experience for those pursuing a career in general surgery. Published by Elsevier Inc.

  1. No more broken hearts: weight loss after bariatric surgery returns patients' postoperative risk to baseline following coronary surgery.

    PubMed

    Baimas-George, Maria; Hennings, Dietric L; Al-Qurayshi, Zaid; Emad Kandil; DuCoin, Christopher

    2017-06-01

    The obesity epidemic is associated with a rise in coronary surgeries because obesity is a risk factor for coronary artery disease. Bariatric surgery is linked to improvement in cardiovascular co-morbidities and left ventricular function. No studies have investigated survival advantage in postoperative bariatric patients after coronary surgery. To determine if there is a benefit after coronary surgery in patients who have previously undergone bariatric surgery. National Inpatient Sample. We performed a retrospective, cross-sectional analysis of the National Inpatient Sample database from 2003 to 2010. We selected bariatric surgical patients who later underwent coronary surgery (n = 257). A comparison of postoperative complications and mortality after coronary surgery were compared with controls (n = 1442) using χ 2 tests, linear regression analysis, and multivariate logistical regression models. A subset population was identified as having undergone coronary surgery (n = 1699); of this population, 257 patients had previously undergone bariatric surgery. They were compared with 1442 controls. The majority was male (67.2%), white (82.6%), and treated in an urban environment (96.8%). Patients with bariatric surgery assumed the risk of postoperative complications after coronary surgery that was associated with their new body mass index (BMI) (BMI<25 kg/m 2 : odds ratio (OR) 1.01, 95% CI .76-1.34, P = .94; BMI 25 to<35 kg/m 2 : OR .20, 95% CI .02- 2 .16, P = .19; BMI≥35 kg/m 2 : OR>999.9, 95% CI .18 to>999.9, P = .07). Length of stay was significantly longer in postbariatric patients (BMI<25, OR 1.62, 95% CI 1.14-2.30, P = .007). Postoperative bariatric patients have a return to baseline risk of morbidity and mortality after coronary surgery. Copyright © 2017 American Society for Bariatric Surgery. Published by Elsevier Inc. All rights reserved.

  2. Bariatric surgery in patients with bipolar spectrum disorders: Selection factors, post-operative visit attendance, and weight outcomes

    PubMed Central

    Friedman, Kelli E.; Applegate, Katherine; Portenier, Dana; McVay, Megan

    2017-01-01

    Background As many of 3% of bariatric surgery candidates are diagnosed with a bipolar spectrum disorder. Objectives 1) To describe differences between patients with bipolar spectrum disorders who are approved and not approved for surgery by the mental health evaluator. 2) To examine surgical outcomes of patients with bipolar spectrum disorders. Setting Academic medical center, United States. Methods A retrospective record review was conducted of consecutive patients who applied for bariatric surgery between 2004 and 2009. Patients diagnosed with bipolar spectrum disorders who were approved for surgery (n=42) were compared with patients with a bipolar spectrum disorder who were not approved (n=31) and to matched control surgical patients without a bipolar spectrum diagnosis (n=29) on a variety of characteristics and surgical outcomes. Results Of bariatric surgery candidates diagnosed with a bipolar spectrum disorder who applied for surgery, 57% were approved by the psychologist and 48% ultimately had surgery. Patients with a bipolar spectrum disorder who were approved for surgery were less likely to have had a previous psychiatric hospitalizations than those who were not approved for surgery. Bariatric surgery patients diagnosed with a bipolar spectrum disorder were less likely to attend follow-up care appointments 2 or more years post-surgery compared to matched patients without bipolar disorder. Among patients with available data, those with a bipolar spectrum disorder and matched patients had similar weight loss at 12 months (n=21 for bipolar, n=24 for matched controls) and at 2 or more years (mean=51 months; n=11 for bipolar, n=20 for matched controls). Conclusions Patients diagnosed with a bipolar spectrum disorder have a high rate of delay/denial for bariatric surgery based on the psychosocial evaluation and are less likely to attend medical follow-up care 2 or more years post-surgery. Carefully screened patients with bipolar disorder who engage in long-term follow-up care may benefit from bariatric surgery. PMID:28169206

  3. Acute care surgery: impact on practice and economics of elective surgeons.

    PubMed

    Miller, Preston R; Wildman, Elizabeth A; Chang, Michael C; Meredith, J Wayne

    2012-04-01

    The creation of an acute care surgery service provides a rich operative experience for acute care surgeons. Elective surgeons typically have concerns about whether their practice volume will be restored with elective cases. Acute care surgery has financial implications for both groups. The aim of this project is to examine the impact in terms of work relative value units (wRVUs), collections, and cases in both groups with creation of an acute care surgery service at our institution. Work RVUs, collections, and case volume were examined from departmental records for 2 groups before and after acute care surgery service creation. The service began on September 1, 2008. Before this time, emergency surgical consults went to the general surgeon on call. After this date, all emergency consults were seen by acute care surgeons. The number of operations performed by the acute care surgery group increased significantly when the mean of the 2 years after institution of acute care surgery were compared with the mean of the 2 years preceding the service creation (1,639 vs 790/year; p = 0.007). There was no change in total operations done by the elective surgery group (2,763 vs 2,496/year: p = 0.13). Elective caseload, however, did increase by 23% in the elective surgery group. In the acute care surgery group, wRVUs increased by 140% and elective surgery group wRVUs decreased by 8%. Collections increased in both groups (acute care surgery 129%, elective surgery 7%) and the combined collections of the groups increased by $2,138,00 in the year after service creation. Acute care surgery service creation took emergency business from the elective surgery group, but this was almost immediately replaced with elective cases. This resulted in higher collections for both groups and a resultant significant increase in collections in aggregate. Copyright © 2012 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  4. Use of antibiotics for urinary tract infection in women undergoing surgery for urinary incontinence: a cohort study.

    PubMed

    Guldberg, Rikke; Kesmodel, Ulrik Schiøler; Brostrøm, Søren; Kærlev, Linda; Hansen, Jesper Kjær; Hallas, Jesper; Nørgård, Bente Mertz

    2014-02-04

    To describe the use of antibiotics for urinary tract infection (UTI) before and after surgery for urinary incontinence (UI); and for those with use of antibiotics before surgery, to estimate the risk of treatment for a postoperative UTI, relative to those without use of antibiotics before surgery. A historical population-based cohort study. Denmark. Women (age ≥18 years) with a primary surgical procedure for UI from the county of Funen and the Region of Southern Denmark from 1996 throughout 2010. Data on redeemed prescriptions of antibiotics ±365 days from the date of surgery were extracted from a prescription database. Use of antibiotics for UTI in relation to UI surgery, and the risk of being a postoperative user of antibiotics for UTI among preoperative users. A total of 2151 women had a primary surgical procedure for UI; of these 496 (23.1%) were preoperative users of antibiotics for UTI. Among preoperative users, 129 (26%) and 215 (43.3%) also redeemed prescriptions of antibiotics for UTI within 0-60 and 61-365 days after surgery, respectively. Among preoperative non-users, 182 (11.0%) and 235 (14.2%) redeemed prescriptions within 0-60 and 61-365 days after surgery, respectively. Presurgery exposure to antibiotics for UTI was a strong risk factor for postoperative treatment for UTI, both within 0-60 days (adjusted OR, aOR=2.6 (95% CI 2.0 to 3.5)) and within 61-365 days (aOR=4.5 (95% CI 3.5 to 5.7)). 1 in 4 women undergoing surgery for UI was treated for UTI before surgery, and half of them had a continuing tendency to UTIs after surgery. Use of antibiotics for UTI before surgery was a strong risk factor for antibiotic use after surgery. In women not using antibiotics for UTI before surgery only a minor proportion initiated use after surgery.

  5. "A journey around the world": Parent narratives of the journey to pediatric resective epilepsy surgery and beyond.

    PubMed

    Baca, Christine B; Pieters, Huibrie C; Iwaki, Tomoko J; Mathern, Gary W; Vickrey, Barbara G

    2015-06-01

    Although shorter time to pediatric resective epilepsy surgery is strongly associated with greater disease severity, other nonclinical diagnostic and sociodemographic factors also play a role. We aimed to examine parent-reported barriers to timely receipt of pediatric epilepsy surgery. We conducted 37 interviews of parents of children who previously had resective epilepsy surgery at University of California Los Angeles (UCLA; 2006-2011). Interviews were audio-recorded, transcribed, and systematically coded using thematic analysis by two independent coders, and subsequently checked for agreement. Clinical data, including "time to surgery" (age of epilepsy onset to surgery) were abstracted from medical records. The mean time to surgery was 5.3 years (standard deviation [SD] 3.8); surgery types included 32% hemispherectomy, 43% lobar/focal, and 24% multilobar. At surgery, parents were on average 38.4 years (SD 6.6) and children were on average 8.2 years (SD 4.7). The more arduous and longer aspect of the journey to surgery was perceived by parents to be experienced prior to presurgical referral. The time from second antiepileptic drug failure to presurgical referral was ≥ 1 year in 64% of children. Thematic analysis revealed four themes (with subthemes) along the journey to surgery and beyond: (1) recognition--"something is wrong" (unfamiliarity with epilepsy, identification of medical emergency); (2) searching and finding--"a circuitous journey" (information seeking, finding the right doctors, multiple medications, insurance obstacles, parental stress); (3) surgery is a viable option--"the right spot" (surgery as last resort, surgery as best option, hoping for candidacy); and (4) life now--"we took the steps we needed to" (a new life, giving back). Multipronged interventions targeting parent-, provider-, and system-based barriers should focus on the critical presurgical referral period; such interventions are needed to remediate delays and improve access to subspecialty care for children with medically refractory epilepsy and potentially eligible for surgery. Wiley Periodicals, Inc. © 2015 International League Against Epilepsy.

  6. Informed Consent and Cognitive Dysfunction After Noncardiac Surgery in the Elderly.

    PubMed

    Hogan, Kirk J; Bratzke, Lisa C; Hogan, Kendra L

    2018-02-01

    Cognitive dysfunction 3 months after noncardiac surgery in the elderly satisfies informed consent thresholds of foreseeability in 10%-15% of patients, and materiality with new deficits observed in memory and executive function in patients with normal test performance beforehand. At present, the only safety step to avoid cognitive dysfunction after surgery is to forego surgery, thereby precluding the benefits of surgery with removal of pain and inflammation, and resumption of normal nutrition, physical activity, and sleep. To assure that consent for surgery is properly informed, risks of both cognitive dysfunction and alternative management strategies must be discussed with patients by the surgery team before a procedure is scheduled.

  7. Ocular Melanoma

    MedlinePlus

    ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Academy Publications EyeNet Ophthalmology ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Find an Ophthalmologist Advanced ...

  8. Herpes Keratitis

    MedlinePlus

    ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Academy Publications EyeNet Ophthalmology ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Find an Ophthalmologist Advanced ...

  9. Black Eye

    MedlinePlus

    ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Academy Publications EyeNet Ophthalmology ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Find an Ophthalmologist Advanced ...

  10. Ocular Hypertension

    MedlinePlus

    ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Academy Publications EyeNet Ophthalmology ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Find an Ophthalmologist Advanced ...

  11. Corneal Ulcer

    MedlinePlus

    ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Academy Publications EyeNet Ophthalmology ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Find an Ophthalmologist Advanced ...

  12. Bacterial Keratitis

    MedlinePlus

    ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Academy Publications EyeNet Ophthalmology ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Find an Ophthalmologist Advanced ...

  13. Fungal Keratitis

    MedlinePlus

    ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Academy Publications EyeNet Ophthalmology ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Find an Ophthalmologist Advanced ...

  14. Eye Symptoms

    MedlinePlus

    ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Academy Publications EyeNet Ophthalmology ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Find an Ophthalmologist Advanced ...

  15. Protective Eyewear

    MedlinePlus

    ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Academy Publications EyeNet Ophthalmology ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Find an Ophthalmologist Advanced ...

  16. Preoperative Testing

    MedlinePlus

    ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Academy Publications EyeNet Ophthalmology ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Find an Ophthalmologist Advanced ...

  17. Eye Allergies

    MedlinePlus

    ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Academy Publications EyeNet Ophthalmology ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Find an Ophthalmologist Advanced ...

  18. Female sexuality and consent in public discourse: James Burt's "love surgery".

    PubMed

    Rodriguez, Sarah B

    2013-04-01

    Beginning in the mid-1960s, gynecologist and obstetrician James Burt developed what he called "love surgery" on unknowing women after they gave birth. It was, he later told them, a modification of episiotomy repair. In the mid-1970s, Burt began promoting love surgery as an elective sexual enhancement surgery and women came to his clinic in hopes of a surgically-enabled better sex life. But though Burt now offered love surgery, he continued to perform it on patients who did not come to him for it through the late 1980s. Over the course of more than two decades, discourse on love surgery occurred twice nationally. In the late 1970s, feminists and sex therapists attacked love surgery as altering a woman's body for male sexual pleasure. Though Burt never hid his continued use of love surgery on women who had not elected for it, the public discourse at this time focused on love surgery as a reflection of larger cultural ideas about female sexuality. In the late 1980s, when Burt's love surgery again appeared in the national media, the issue of informed consent, largely absent from the discourse about love surgery in the late 1970s, moved to the center. Though significant activity happened within the local medical and legal communities beginning in the mid-1970s regarding Burt and his practice of love surgery, my interest here is on these two periods when the discourse regarding love surgery, female sexuality, and informed consent occurred within a national frame.

  19. Outpatient versus Inpatient Primary Cleft Lip and Palate Surgery: Analysis of Early Complications.

    PubMed

    Kantar, Rami S; Cammarata, Michael J; Rifkin, William J; Plana, Natalie M; Diaz-Siso, J Rodrigo; Flores, Roberto L

    2018-05-01

    Fiscal constraints are driving shorter hospital lengths of stay. Outpatient primary cleft lip surgery has been shown to be safe, but outpatient primary cleft palate surgery remains controversial. This study evaluates outcomes following outpatient versus inpatient primary cleft lip and palate surgery. The American College of Surgeons National Surgical Quality Improvement Program Pediatric database was used to identify patients undergoing primary cleft lip and palate surgery between 2012 and 2015. Patient clinical factors and 30-day complications were compared for outpatient versus inpatient primary cleft lip and palate surgery. Univariate and multivariate analyses were performed. Three thousand one hundred forty-two patients were included in the primary cleft lip surgery group and 4191 in the primary cleft palate surgery group. Patients in the cleft lip surgery group with structural pulmonary abnormalities had a significantly longer hospital length of stay (β, 4.94; p = 0.001). Patients undergoing outpatient surgery had a significantly higher risk of superficial (OR, 1.99; p = 0.01) and deep wound dehiscence (OR, 2.22; p = 0.01), and were at a significantly lower risk of reoperation (OR, 0.36; p = 0.04) and readmission (OR, 0.52; p = 0.02). Outpatient primary cleft lip surgery is safe and has a complication profile similar to that of inpatient surgery. Outpatient primary cleft palate surgery is common practice in many U.S. hospitals and has a significantly higher rate of wound complications, and lower rates of reoperation and readmission. In properly selected patients, outpatient palatoplasty can be performed safely. Therapeutic, III.

  20. The national comparative audit of surgery for nasal polyposis and chronic rhinosinusitis.

    PubMed

    Hopkins, C; Browne, J P; Slack, R; Lund, V; Topham, J; Reeves, B; Copley, L; Brown, P; van der Meulen, J

    2006-10-01

    This study summarises the results of a National Audit of sino-nasal surgery carried out in England and Wales. It describes patient and operative characteristics as well as patient outcomes up to 36 months after surgery. Prospective cohort study. NHS hospitals in England and Wales. Consecutive patients undergoing surgery for nasal polyposis and/or chronic rhinosinusitis. The total score derived from a 22-item version of the Sino-Nasal Outcome Test (SNOT-22). Lower scores represent better health-related quality of life. A total of 3128 consecutive patients at 87 NHS hospitals were enrolled. There is a large improvement in SNOT-22 scores from the pre-operative period (mean = 42.0) to 3 months after surgery (mean = 25.5). The scores for patients undergoing nasal polypectomy improved from 41.0 before surgery to 23.1 at 3 months after surgery, while the scores for patients undergoing surgery for chronic rhinosinusitis alone improved from 44.2 to 31.2. The SNOT-22 scores reported at 12 and 36 months after surgery were similar to those reported at 3 months. Excessive bleeding occurred in 5% of patients during the operation and in 1% of patients after the operation. Intra-orbital complications were reported in 0.2%. Of those patients undergoing primary surgery for bilateral grade I or II polyposis, 18% had not received a pre-operative course of steroid treatment. At the 36-month follow-up, 11.4% of patients had undergone revision surgery. The audit confirms that sino-nasal surgery is generally safe and effective. There is some evidence that patient selection for surgery could be improved.

  1. Roux-en-Y Gastric Bypass Surgery Induces Early Plasma Metabolomic and Lipidomic Alterations in Humans Associated with Diabetes Remission.

    PubMed

    Arora, Tulika; Velagapudi, Vidya; Pournaras, Dimitri J; Welbourn, Richard; le Roux, Carel W; Orešič, Matej; Bäckhed, Fredrik

    2015-01-01

    Roux-en-Y gastric bypass (RYGB) is an effective method to attain sustained weight loss and diabetes remission. We aimed to elucidate early changes in the plasma metabolome and lipidome after RYGB. Plasma samples from 16 insulin-resistant morbidly obese subjects, of whom 14 had diabetes, were subjected to global metabolomics and lipidomics analysis at pre-surgery and 4 and 42 days after RYGB. Metabolites and lipid species were compared between time points and between subjects who were in remission and not in remission from diabetes 2 years after surgery. We found that the variables that were most discriminatory between time points were decanoic acid and octanoic acid, which were elevated 42 days after surgery, and sphingomyelins (18:1/21:0 and 18:1/23:3), which were at their lowest level 42 days after surgery. Insulin levels were lower at 4 and 42 days after surgery compared with pre-surgery levels. At 4 days after surgery, insulin levels correlated positively with metabolites of branched chain and aromatic amino acid metabolism and negatively with triglycerides with long-chain fatty acids. Of the 14 subjects with diabetes prior to surgery, 7 were in remission 2 years after surgery. The subjects in remission displayed higher pre-surgery levels of tricarboxylic acid cycle intermediates and triglycerides with long-chain fatty acids compared with subjects not in remission. Thus, metabolic alterations are induced soon after surgery and subjects with diabetes remission differ in the metabolic profiles at pre- and early post-surgery time points compared to patients not in remission.

  2. Current State of Overlapping, Concurrent, and Multiple-Room Surgery in Otolaryngology: A National Survey.

    PubMed

    Cognetti, David M; Nussenbaum, Brian; Brenner, Michael J; Chi, David H; McCormick, Michael E; Venkatraman, Giri; Zhan, Tingting; McKinlay, Alex J

    2017-12-01

    Objective Multiple-room surgery has gained attention due to reports in the lay press scrutinizing the activity, with hospitals and the government collecting data on current practice. We studied practices and attitudes toward multiple-room surgery in otolaryngology. Methods A survey was developed by members of the Patient Safety and Quality Improvement Committee of the American Academy of Otolaryngology-Head and Neck Surgery. The survey was distributed to members of the Academy and included questions on demographics, current practices, and opinions regarding multiple-room surgery. The survey was designed to capture the spectrum of multidisciplinary, overlapping, and simultaneous/concurrent surgery practices. Data were collected via SurveyMonkey. Results A total of 907 of 9520 members completed the survey. Of the respondents, 40.4% reported performing some form of multiple-room surgery. Multiple-room surgery is more common amongst subspecialists than general otolaryngologists. Most believed that regulations disallowing multiple-room surgery would result in an increase in late starts (73.5%), an increase in the time to schedule surgery (84.5%), a detriment to residency training (63.1%), and no improvement in patient safety (60%.) Discussion Multiple-room surgery is common among responding otolaryngologists. Most respondents consider the practice to serve a role in facilitating access, efficiency, and training. Implications for Practice Due to recent attention placed on multiple-room surgery, institutions are reviewing policies regarding the practice. This survey suggests that policy changes that restrict multiple-room surgery must consider a potential unintended negative impact on patient care and access.

  3. Current Status of Surgical Planning for Orthognathic Surgery: Traditional Methods versus 3D Surgical Planning

    PubMed Central

    Hammoudeh, Jeffrey A.; Howell, Lori K.; Boutros, Shadi; Scott, Michelle A.

    2015-01-01

    Background: Orthognathic surgery has traditionally been performed using stone model surgery. This involves translating desired clinical movements of the maxilla and mandible into stone models that are then cut and repositioned into class I occlusion from which a splint is generated. Model surgery is an accurate and reproducible method of surgical correction of the dentofacial skeleton in cleft and noncleft patients, albeit considerably time-consuming. With the advent of computed tomography scanning, 3D imaging and virtual surgical planning (VSP) have gained a foothold in orthognathic surgery with VSP rapidly replacing traditional model surgery in many parts of the country and the world. What has yet to be determined is whether the application and feasibility of virtual model surgery is at a point where it will eliminate the need for traditional model surgery in both the private and academic setting. Methods: Traditional model surgery was compared with VSP splint fabrication to determine the feasibility of use and accuracy of application in orthognathic surgery within our institution. Results: VSP was found to generate acrylic splints of equal quality to model surgery splints in a fraction of the time. Drawbacks of VSP splint fabrication are the increased cost of production and certain limitations as it relates to complex craniofacial patients. Conclusions: It is our opinion that virtual model surgery will displace and replace traditional model surgery as it will become cost and time effective in both the private and academic setting for practitioners providing orthognathic surgical care in cleft and noncleft patients. PMID:25750846

  4. Risk factors associated with postoperative pain after ophthalmic surgery: a prospective study

    PubMed Central

    Lesin, Mladen; Dzaja Lozo, Mirna; Duplancic-Sundov, Zeljka; Dzaja, Ivana; Davidovic, Nikolina; Banozic, Adriana; Puljak, Livia

    2016-01-01

    Background Risk factors associated with postoperative pain intensity and duration, as well as consumption of analgesics after ophthalmic surgery are poorly understood. Methods A prospective study was conducted among adults (N=226) who underwent eye surgery at the University Hospital Split, Croatia. A day before the surgery, the patients filled out questionnaires assessing personality, anxiety, pain catastrophizing, sociodemographics and were given details about the procedure, anesthesia, and analgesia for each postoperative day. All scales were previously used for the Croatian population. The intensity of pain was measured using a numerical rating scale from 0 to 10, where 0 was no pain and 10 was the worst imaginable pain. The intensity of pain was measured before the surgery and then 1 hour, 3 hours, 6 hours, and 24 hours after surgery, and then once a day until discharge from the hospital. Univariate and multivariate analyses were performed. Results A multivariate analysis indicated that independent predictors of average pain intensity after the surgery were: absence of premedication before surgery, surgery in general anesthesia, higher pain intensity before surgery and pain catastrophizing level. Independent predictors of postoperative pain duration were intensity of pain before surgery, type of anesthesia, and self-assessment of health. Independent predictors of pain intensity ≥5 during the first 6 hours after the procedure were the type of procedure, self-assessment of health, premedication, and the level of pain catastrophizing. Conclusion Awareness about independent predictors associated with average postoperative pain intensity, postoperative pain duration, and occurrence of intensive pain after surgery may help health workers to improve postoperative pain management in ophthalmic surgery. PMID:26858525

  5. Roux-en-Y Gastric Bypass Surgery Induces Early Plasma Metabolomic and Lipidomic Alterations in Humans Associated with Diabetes Remission

    PubMed Central

    Pournaras, Dimitri J.; Welbourn, Richard; le Roux, Carel W.; Orešič, Matej; Bäckhed, Fredrik

    2015-01-01

    Roux-en-Y gastric bypass (RYGB) is an effective method to attain sustained weight loss and diabetes remission. We aimed to elucidate early changes in the plasma metabolome and lipidome after RYGB. Plasma samples from 16 insulin-resistant morbidly obese subjects, of whom 14 had diabetes, were subjected to global metabolomics and lipidomics analysis at pre-surgery and 4 and 42 days after RYGB. Metabolites and lipid species were compared between time points and between subjects who were in remission and not in remission from diabetes 2 years after surgery. We found that the variables that were most discriminatory between time points were decanoic acid and octanoic acid, which were elevated 42 days after surgery, and sphingomyelins (18:1/21:0 and 18:1/23:3), which were at their lowest level 42 days after surgery. Insulin levels were lower at 4 and 42 days after surgery compared with pre-surgery levels. At 4 days after surgery, insulin levels correlated positively with metabolites of branched chain and aromatic amino acid metabolism and negatively with triglycerides with long-chain fatty acids. Of the 14 subjects with diabetes prior to surgery, 7 were in remission 2 years after surgery. The subjects in remission displayed higher pre-surgery levels of tricarboxylic acid cycle intermediates and triglycerides with long-chain fatty acids compared with subjects not in remission. Thus, metabolic alterations are induced soon after surgery and subjects with diabetes remission differ in the metabolic profiles at pre- and early post-surgery time points compared to patients not in remission. PMID:25946120

  6. Epidemiological, demographic, and economic analyses: measurement of the value of trichiasis surgery in The Gambia.

    PubMed

    Frick, K D; Keuffel, E L; Bowman, R J

    2001-07-01

    Untreated trichiasis can lead to corneal opacity. Surgery to prevent the eyelashes from rubbing against the cornea is available, but many individuals with trichiasis never undergo the operation. This study estimates the cost of illness of untreated trichiasis and the willingness to pay for surgery and compares them with the actual cost of providing surgery. The cost of illness estimate is based on trichiasis patient demographics. Data on the implicit price of obtaining surgery and surgical utilization in a matched pair randomized trial are used to infer individual willingness to pay for trichiasis surgery. Patients in the study paid nothing out-of-pocket for surgery; the price of obtaining surgery is the value of the individual's time needed for travel and surgery plus the price of public transportation. The cost of producing surgery was calculated from project records. All monetary figures are reported in 1998 US dollars. The average cost of untreated trichiasis, or the net present value of life-time lost economic productivity, was $89. Individuals facing a lower cost were more likely to undergo an operation; the inferred average willingness to pay was $1.43 (SD 0.244). Surgery cost $6.13 to provide, including $0.86 for transportation to the village. Whether the value of trichiasis surgery exceeds the cost in The Gambia depends on how the value is measured. Individuals are willing to use only limited resources to obtain surgery even though lifetime economic productivity may increase substantially. All three economic measures can be used to inform policy.

  7. Robotics in reproductive medicine.

    PubMed

    Sroga, Julie; Patel, Sejal Dharia; Falcone, Tommaso

    2008-01-01

    In the past decade, robotic technology has been increasingly incorporated into various industries, including surgery and medicine. This chapter will review the history, development, current applications, and future of robotic technology in reproductive medicine. A literature search was performed for all publications regarding robotic technology in medicine, surgery, reproductive endocrinology, and its role in both surgical education and telepresence surgery. As robotic assisted surgery has emerged, this technology provides a feasible option for minimally invasive surgery, impacts surgical education, and plays a role in telepresence surgery.

  8. [Basics of Ear Surgery].

    PubMed

    Lailach, S; Zahnert, T

    2016-12-01

    The present article about the basics of ear surgery is a short overview of current indications, the required diagnostics and surgical procedures of common otologic diseases. In addition to plastic and reconstructive surgery of the auricle, principles of surgery of the external auditory canal, basics of middle ear surgery and the tumor surgery of the temporal bone are shown. Additionally, aspects of the surgical hearing rehabilitation (excluding implantable hearing systems) are presented considering current study results. Georg Thieme Verlag KG Stuttgart · New York.

  9. The new era of robotic neck surgery: The universal application of the retroauricular approach.

    PubMed

    Byeon, Hyung Kwon; Koh, Yoon Woo

    2015-12-01

    Recent advances in technology has triggered the introduction of surgical robotics in the field of head and neck surgery and changed the landscape indefinitely. The advent of transoral robotic surgery and robotic thyroidectomy techniques has urged the extended applications of the robot to other neck surgeries including remote access surgeries. Based on earlier reports and our surgical experiences, this review will discuss in detail various robotic head and neck surgeries via retroauricular approach. © 2015 Wiley Periodicals, Inc.

  10. [The therapeutic function of cosmetic surgery].

    PubMed

    Saboye, J

    2012-08-01

    The therapeutic purpose or not of cosmetic surgery is the criterion chosen by the tax authorities to secure acts for aesthetic purposes to VAT. Purpose and necessity of medical therapy are often confused. Yet there are two distinct concepts. In the case of cosmetic surgery, its therapeutic purpose is recognized by physicians and judges. This is the psychological improvement after surgery, well be secondary to surgery, although be desired by the WHO, which demonstrates the therapeutic purpose of cosmetic surgery. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  11. [Cataract surgery and its impact on balance and autonomy in elderly].

    PubMed

    Raynal, M; Aupy, B; Jahidi, A; Ettien, D; Le Page, P; Briche, T; Kossowski, M; Pailllaud, E

    2009-01-01

    Cataract is a major cause of visual impairment among elderly. Cataract surgery improves visual afferencies and can have an impact on balance. The present study assessed the impact of cataract surgery upon balance and autonomy in elderly. We realized clinical examinations and objective tests the day before surgery and 2-months later. The initial cohort consisted of 66 patients that had to undergo a cataract surgery. Their mean age was 79 +/- 0.5. For logistic reasons, only 33 patients have been completely evaluated before and after surgery. Each patient underwent a history and examination that have assessed autonomy, walking, visual and then cochleo-vestibular functions including bone vibratory test and dynamic computerized posturography (Equitest). After 2 months, cataract surgery had no incidence on balance. The fear of falling has stayed the same whereas the number of falls has been noticeably reduced by surgery. The overall score of Equitest has shown an increase in visual dependence after surgery. Although cataract surgery has no incidence on autonomy, it may improve the quality of life among older people by leisure activities recovery. An early physical rehabilitation facilitated by visual improvement after surgery can also prevent visual dependence and autonomy loss. We recommend vestibular rehabilitation in elderly with major visual dependence.

  12. Innovation in Pediatric Surgical Education for General Surgery Residents: A Mobile Web Resource.

    PubMed

    Rouch, Joshua D; Wagner, Justin P; Scott, Andrew; Sullins, Veronica F; Chen, David C; DeUgarte, Daniel A; Shew, Stephen B; Tillou, Areti; Dunn, James C Y; Lee, Steven L

    2015-01-01

    General surgery residents lack a standardized educational experience in pediatric surgery. We hypothesized that the development of a mobile educational interface would provide general surgery residents broader access to pediatric surgical education materials. We created an educational mobile website for general surgery residents rotating on pediatric surgery, which included a curriculum, multimedia resources, the Operative Performance Rating Scale (OPRS), and Twitter functionality. Residents were instructed to consult the curriculum. Residents and faculty posted media using the Twitter hashtag, #UCLAPedSurg, and following each surgical procedure reviewed performance via the OPRS. Site visits, Twitter posts, and OPRS submissions were quantified from September 2013 to July 2014. The pediatric surgery mobile website received 257 hits; 108 to the homepage, 107 to multimedia, 28 to the syllabus, and 19 to the OPRS. All eligible residents accessed the content. The Twitter hashtag, #UCLAPedSurg, was assigned to 20 posts; the overall audience reach was 85 individuals. Participants in the mobile OPRS included 11 general surgery residents and 4 pediatric surgery faculty. Pediatric surgical education resources and operative performance evaluations are effectively administered to general surgery residents via a structured mobile platform. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  13. A cost and policy analysis comparing immediate sequential cataract surgery and delayed sequential cataract surgery from the physician perspective in the United States.

    PubMed

    Neel, Sean T

    2014-11-01

    A cost analysis was performed to evaluate the effect on physicians in the United States of a transition from delayed sequential cataract surgery to immediate sequential cataract surgery. Financial and efficiency impacts of this change were evaluated to determine whether efficiency gains could offset potential reduced revenue. A cost analysis using Medicare cataract surgery volume estimates, Medicare 2012 physician cataract surgery reimbursement schedules, and estimates of potential additional office visit revenue comparing immediate sequential cataract surgery with delayed sequential cataract surgery for a single specialty ophthalmology practice in West Tennessee. This model should give an indication of the effect on physicians on a national basis. A single specialty ophthalmology practice in West Tennessee was found to have a cataract surgery revenue loss of $126,000, increased revenue from office visits of $34,449 to $106,271 (minimum and maximum offset methods), and a net loss of $19,900 to $91,700 (base case) with the conversion to immediate sequential cataract surgery. Physicians likely stand to lose financially, and this loss cannot be offset by increased patient visits under the current reimbursement system. This may result in physician resistance to converting to immediate sequential cataract surgery, gaming, and supplier-induced demand.

  14. [The risk of surgical glove perforations].

    PubMed

    Hagen, Gerd Ødegård; Arntzen, Halvard

    2007-03-29

    The increasing prevalence of blood-borne viral diseases has drawn attention to the barrier between the surgical personnel's hands and the patients body fluids during surgery. At present, the typical practice is to use double gloving in orthopaedic surgery, and single gloving in other types of surgery. The main purpose of our study was to estimate and compare the perforation risk in different categories of surgery. In a series of 655 surgical operations covering 5 main categories of surgery, all detected glove perforations were recorded and analysed. Perforations were found in 203 out of 655 operations (31%). The observed perforation frequency was 44.5% in gastrointestinal surgery, 34.7% in orthopaedic surgery, 31.1% in gynaecology, 18.6% in vascular surgery and 9.2% in general surgery. In some subcategories, the frequencies were even higher. In several categories of surgery, we found high perforation frequencies. Perforations in single gloves are often not detected during operations. This may increase the risk of transmission of blood-borne infections, particularly because the time of exposure may be long. Double indicator gloves make the intra-operative detection of perforations easier. Also double gloving is known to significantly reduce the perforation risk. The use of double indicator gloves is recommended in all categories of surgery.

  15. Planning Strabismus Surgery: How to Avoid Pitfalls and Complications.

    PubMed

    Aroichane, Maryam

    2016-01-01

    Good surgical results following strabismus surgery depend on several factors. In this article, detailed steps for planning strabismus surgery will be reviewed for basic horizontal strabismus surgery, vertical, and oblique muscle surgeries. The thought process behind each case will be presented to help in selecting the best surgical approach to optimize postoperative results. The surgical planning for strabismus will be developed with clinical examples from easy cases to more complex ones. Preoperative pictures of the ocular alignment are an integral part of planning surgery and help in documenting the strabismus before and after surgery. Three cases of strabismus cases will be reviewed with several key factors for planning surgery, including visual acuity, refractive error, potential for stereovision, and risk of postoperative diplopia. The most important factor is accurate orthoptic measurements. The surgical planning for each patient is detailed along with preoperative pictures. Strabismus surgery results can be improved by careful preoperative planning. The surgeon has the ability to discern potential pitfalls that can alter the surgical outcome. Surgical planning allows a dedicated time of reflection before surgery, foreseeing potential problems, and avoiding them during the surgery. © 2016 Board of regents of the University of Wisconsin System, American Orthoptic Journal, Volume 66, 2016, ISSN 0065-955X, E-ISSN 1553-4448.

  16. The complexity of body image following bariatric surgery: a systematic review of the literature.

    PubMed

    Ivezaj, V; Grilo, C M

    2018-06-13

    Poor body image is common among individuals seeking bariatric surgery and is associated with adverse psychosocial sequelae. Following massive weight loss secondary to bariatric surgery, many individuals experience excess skin and associated concerns, leading to subsequent body contouring procedures. Little is known, however, about body image changes and associated features from pre-to post-bariatric surgery and subsequent body contouring. The objective of the present study was to conduct a comprehensive literature review of body image following bariatric surgery to help inform future clinical research and care. The articles for the current review were identified by searching PubMed and SCOPUS and references from relevant articles. A total of 60 articles examining body image post-bariatric surgery were identified, and 45 did not include body contouring surgery. Overall, there was great variation in standards of reporting sample characteristics and body image terms. When examining broad levels of body image dissatisfaction, the literature suggests general improvements in certain aspects of body image following bariatric surgery; however, few studies have systematically examined various body image domains from pre-to post-bariatric surgery and subsequent body contouring surgery. In conclusion, there is a paucity of research that examines the multidimensional elements of body image following bariatric surgery. © 2018 World Obesity Federation.

  17. The evolving application of single-port robotic surgery in general surgery.

    PubMed

    Qadan, Motaz; Curet, Myriam J; Wren, Sherry M

    2014-01-01

    Advances in the field of minimally invasive surgery have grown since the original advent of conventional multiport laparoscopic surgery. The recent development of single incision laparoscopic surgery remains a relatively novel technique, and has had mixed reviews as to whether it has been associated with lower pain scores, shorter hospital stays, and higher satisfaction levels among patients undergoing procedures through cosmetically-appeasing single incisions. However, due to technical difficulties that arise from the clustering of laparoscopic instruments through a confined working space, such as loss of instrument triangulation, poor surgical exposure, and instrument clashing, uptake by surgeons without a specific interest and expertise in cutting-edge minimally invasive approaches has been limited. The parallel use of robotic surgery with single-port platforms, however, appears to counteract technical issues associated with single incision laparoscopic surgery through significant ergonomic improvements, including enhanced instrument triangulation, organ retraction, and camera localization within the surgical field. By combining the use of the robot with the single incision platform, the recognized challenges of single incision laparoscopic surgery are simplified, while maintaining potential advantages of the single-incision minimally invasive approach. This review provides a comprehensive report of the evolving application single-port robotic surgery in the field of general surgery today. © 2013 Japanese Society of Hepato-Biliary-Pancreatic Surgery.

  18. A comparative analysis of minimally invasive and open spine surgery patient education resources.

    PubMed

    Agarwal, Nitin; Feghhi, Daniel P; Gupta, Raghav; Hansberry, David R; Quinn, John C; Heary, Robert F; Goldstein, Ira M

    2014-09-01

    The Internet has become a widespread source for disseminating health information to large numbers of people. Such is the case for spine surgery as well. Given the complexity of spinal surgeries, an important point to consider is whether these resources are easily read and understood by most Americans. The average national reading grade level has been estimated to be at about the 7th grade. In the present study the authors strove to assess the readability of open spine surgery resources and minimally invasive spine surgery resources to offer suggestions to help improve the readability of patient resources. Online patient education resources were downloaded in 2013 from 50 resources representing either traditional open back surgery or minimally invasive spine surgery. Each resource was assessed using 10 scales from Readability Studio Professional Edition version 2012.1. Patient education resources representing traditional open back surgery or minimally invasive spine surgery were all found to be written at a level well above the recommended 6th grade level. In general, minimally invasive spine surgery materials were written at a higher grade level. The readability of patient education resources from spine surgery websites exceeds the average reading ability of an American adult. Revisions may be warranted to increase quality and patient comprehension of these resources to effectively reach a greater patient population.

  19. Practicing Fireworks Safety

    MedlinePlus

    ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Academy Publications EyeNet Ophthalmology ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Find an Ophthalmologist Advanced ...

  20. What Is Cellulitis?

    MedlinePlus

    ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Academy Publications EyeNet Ophthalmology ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Find an Ophthalmologist Advanced ...

  1. Bell's Palsy Symptoms

    MedlinePlus

    ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Academy Publications EyeNet Ophthalmology ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Find an Ophthalmologist Advanced ...

  2. What Is Glaucoma?

    MedlinePlus

    ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Academy Publications EyeNet Ophthalmology ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Find an Ophthalmologist Advanced ...

  3. Preventing Eye Injuries

    MedlinePlus

    ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Academy Publications EyeNet Ophthalmology ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Find an Ophthalmologist Advanced ...

  4. Cataract Vision Simulator

    MedlinePlus

    ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Academy Publications EyeNet Ophthalmology ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Find an Ophthalmologist Advanced ...

  5. Chalazia and Styes

    MedlinePlus

    ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Academy Publications EyeNet Ophthalmology ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Find an Ophthalmologist Advanced ...

  6. Retinopathy of Prematurity

    MedlinePlus

    ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Academy Publications EyeNet Ophthalmology ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Find an Ophthalmologist Advanced ...

  7. What Is Hemangioma?

    MedlinePlus

    ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Academy Publications EyeNet Ophthalmology ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Find an Ophthalmologist Advanced ...

  8. The Influence of Preoperative and Postoperative Psychological Symptoms on Clinical Outcome after Shoulder Surgery: A Prospective Longitudinal Cohort Study

    PubMed Central

    Koorevaar, Rinco C. T.; van ‘t Riet, Esther; Gerritsen, Marleen J. J.; Madden, Kim; Bulstra, Sjoerd K.

    2016-01-01

    Background Psychological symptoms are highly prevalent in patients with shoulder complaints. Psychological symptoms in patients with shoulder complaints might play a role in the aetiology, perceived disability and pain and clinical outcome of treatment. The aim of this study was to assess whether preoperative symptoms of distress, depression, anxiety and somatisation were associated with a change in function after shoulder surgery and postoperative patient perceived improvement of pain and function. In addition, the change of psychological symptoms after shoulder surgery was analyzed and the influence of postoperative symptoms of psychological disorders after surgery on the change in function after shoulder surgery and perceived postoperative improvement of pain and function. Methods and Findings A prospective longitudinal cohort study was performed in a general teaching hospital. 315 consecutive patients planned for elective shoulder surgery were included. Outcome measures included change of Disabilities of the Arm, Shoulder and Hand (DASH) score and anchor questions about improvement in pain and function after surgery. Psychological symptoms were identified before and 12 months after surgery with the validated Four-Dimensional Symptom Questionnaire (4DSQ). Psychological symptoms were encountered in all the various shoulder diagnoses. Preoperative symptoms of psychological disorders persisted after surgery in 56% of patients, 10% of patients with no symptoms of psychological disorders before surgery developed new psychological symptoms. Preoperative symptoms of psychological disorders were not associated with the change of DASH score and perceived improvement of pain and function after shoulder surgery. Patients with symptoms of psychological disorders after surgery were less likely to improve on the DASH score. Postoperative symptoms of distress and depression were associated with worse perceived improvement of pain. Postoperative symptoms of distress, depression and somatisation were associated with worse perceived improvement of function. Conclusions Preoperative symptoms of distress, depression, anxiety and somatisation were not associated with worse clinical outcome 12 months after shoulder surgery. Symptoms of psychological disorders before shoulder surgery persisted in 56% of patients after surgery. Postoperative symptoms of psychological disorders 12 months after shoulder surgery were strongly associated with worse clinical outcome. PMID:27846296

  9. The Influence of Preoperative and Postoperative Psychological Symptoms on Clinical Outcome after Shoulder Surgery: A Prospective Longitudinal Cohort Study.

    PubMed

    Koorevaar, Rinco C T; van 't Riet, Esther; Gerritsen, Marleen J J; Madden, Kim; Bulstra, Sjoerd K

    2016-01-01

    Psychological symptoms are highly prevalent in patients with shoulder complaints. Psychological symptoms in patients with shoulder complaints might play a role in the aetiology, perceived disability and pain and clinical outcome of treatment. The aim of this study was to assess whether preoperative symptoms of distress, depression, anxiety and somatisation were associated with a change in function after shoulder surgery and postoperative patient perceived improvement of pain and function. In addition, the change of psychological symptoms after shoulder surgery was analyzed and the influence of postoperative symptoms of psychological disorders after surgery on the change in function after shoulder surgery and perceived postoperative improvement of pain and function. A prospective longitudinal cohort study was performed in a general teaching hospital. 315 consecutive patients planned for elective shoulder surgery were included. Outcome measures included change of Disabilities of the Arm, Shoulder and Hand (DASH) score and anchor questions about improvement in pain and function after surgery. Psychological symptoms were identified before and 12 months after surgery with the validated Four-Dimensional Symptom Questionnaire (4DSQ). Psychological symptoms were encountered in all the various shoulder diagnoses. Preoperative symptoms of psychological disorders persisted after surgery in 56% of patients, 10% of patients with no symptoms of psychological disorders before surgery developed new psychological symptoms. Preoperative symptoms of psychological disorders were not associated with the change of DASH score and perceived improvement of pain and function after shoulder surgery. Patients with symptoms of psychological disorders after surgery were less likely to improve on the DASH score. Postoperative symptoms of distress and depression were associated with worse perceived improvement of pain. Postoperative symptoms of distress, depression and somatisation were associated with worse perceived improvement of function. Preoperative symptoms of distress, depression, anxiety and somatisation were not associated with worse clinical outcome 12 months after shoulder surgery. Symptoms of psychological disorders before shoulder surgery persisted in 56% of patients after surgery. Postoperative symptoms of psychological disorders 12 months after shoulder surgery were strongly associated with worse clinical outcome.

  10. Materialism, Sociocultural Appearance Messages, and Paternal Attitudes Predict College Women's Attitudes about Cosmetic Surgery

    ERIC Educational Resources Information Center

    Henderson-King, Donna; Brooks, Kelly D.

    2009-01-01

    Rates of cosmetic surgery procedures have increased dramatically over the past several decades, but only recently have studies of cosmetic surgery attitudes among the general population begun to appear in the literature. The vast majority of those who undergo cosmetic surgery are women. We examined cosmetic surgery attitudes among 218…

  11. 42 CFR 1001.1701 - Billing for services of assistant at surgery during cataract operations.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 5 2013-10-01 2013-10-01 false Billing for services of assistant at surgery during... PROGRAMS Permissive Exclusions § 1001.1701 Billing for services of assistant at surgery during cataract... surgery during a cataract operation, or (ii) Charges that include a charge for an assistant at surgery...

  12. 42 CFR 1001.1701 - Billing for services of assistant at surgery during cataract operations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Billing for services of assistant at surgery during... PROGRAMS Permissive Exclusions § 1001.1701 Billing for services of assistant at surgery during cataract... surgery during a cataract operation, or (ii) Charges that include a charge for an assistant at surgery...

  13. 42 CFR 1001.1701 - Billing for services of assistant at surgery during cataract operations.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 5 2012-10-01 2012-10-01 false Billing for services of assistant at surgery during... PROGRAMS Permissive Exclusions § 1001.1701 Billing for services of assistant at surgery during cataract... surgery during a cataract operation, or (ii) Charges that include a charge for an assistant at surgery...

  14. 42 CFR 1001.1701 - Billing for services of assistant at surgery during cataract operations.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 5 2014-10-01 2014-10-01 false Billing for services of assistant at surgery during... PROGRAMS Permissive Exclusions § 1001.1701 Billing for services of assistant at surgery during cataract... surgery during a cataract operation, or (ii) Charges that include a charge for an assistant at surgery...

  15. 42 CFR 1001.1701 - Billing for services of assistant at surgery during cataract operations.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 5 2011-10-01 2011-10-01 false Billing for services of assistant at surgery during... PROGRAMS Permissive Exclusions § 1001.1701 Billing for services of assistant at surgery during cataract... surgery during a cataract operation, or (ii) Charges that include a charge for an assistant at surgery...

  16. Cosmetic ear surgery

    MedlinePlus

    ... ear reduction. In: Rubin JP, Neligan PC, eds. Plastic Surgery: Volume 2: Aesthetic Surgery . 4th ed. Philadelphia, ... Tang Ho, MD, Assistant Professor, Division of Facial Plastic and Reconstructive Surgery, Department of Otolaryngology – Head and ...

  17. Get Screened at 40

    MedlinePlus

    ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Academy Publications EyeNet Ophthalmology ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Find an Ophthalmologist Advanced ...

  18. What is Color Blindness?

    MedlinePlus

    ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Academy Publications EyeNet Ophthalmology ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Find an Ophthalmologist Advanced ...

  19. Retinal Detachment Vision Simulator

    MedlinePlus

    ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Academy Publications EyeNet Ophthalmology ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Find an Ophthalmologist Advanced ...

  20. Eye Injuries at Home

    MedlinePlus

    ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Academy Publications EyeNet Ophthalmology ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Find an Ophthalmologist Advanced ...

Top