  1. Twenty-four years' implant duration of the aortic Starr-Edwards Silastic ball prosthesis: a valve of the past?

    PubMed

    Mächler, H E; Schmidt, C H; Neuner, P; Iberer, F; Anelli-Monti, M; Dacar, D; Rigler, B; Kraft-Kinz, J

    1993-01-01

    Six years after the first aortic valve replacement with the Starr-Edwards Silastic ball prosthesis at Oregon Health Sciences University, the model 1260 was implanted in a 44-year-old patient at our department. During 24 years no signs of dysfunction, thromboembolism, thrombosis, periprosthetic leaks or hemolysis were observed. Material test showed no signs of fatigue. The dimension of the Silastic poppet was found to be one millimeter less than the original specifications of these poppets and there were some lipid infiltrations. Functionally the poppet was found to be nonvariant. Histologic findings detected focal hyalinization and giant cells without signs of acute inflammation or ulceration. With regard to its reliability and durability, the Starr-Edwards valve prosthesis should not be viewed with disfavor.

  2. Late ball variance with the Model 1000 Starr-Edwards aortic valve prosthesis. Risk analysis and strategy of operative management.

    PubMed

    Grunkemeier, G L; Starr, A

    1986-06-01

    The first generation of aortic ball-valve prostheses, used until 1965, was associated with poppet damage owing to fatty infiltration of the silicone rubber ball, a phenomenon termed ball variance. For the Model 1000 Starr-Edwards valves, almost all cases were discovered before 8 years. However, a review of our patients still at risk with the original valve and poppet, prompted by other recent reports of late ball variance, has shown that severe variance can exist up to 20 years after implantation. There is a relationship between the year of valve implantation and the timing and severity of ball variance for the overall series of patients surviving operation, but for the subgroup currently at risk the sample sizes are too small to detect any difference, if one still exists. Only three of 12 patients in the current subset were found to have severe variance. Simple ball change has been the operation of choice. Prophylactic reoperation is not indicated in the current subset, but patients require careful follow-up and should be considered for reoperation should symptoms develop.

  3. The development of the Starr-Edwards heart valve.

    PubMed Central

    Matthews, A M

    1998-01-01

    Development of the Starr-Edwards heart valve marked a new era in the treatment of valvular heart disease. Until the development of the Starr-Edwards valve, there were no published reports of patients who had lived longer than 3 months with a prosthetic valve in the mitral position. This valve was the result of a unique partnership between a young surgeon, Dr. Albert Starr, and an experienced engineer, Mr. Lowell Edwards. Working as a team, these 2 men developed and successfully implanted the 1st Starr-Edwards valve within less than 2 years of their 1st meeting. Their key to success was their willingness and ability to make repeated modifications to their design to solve each clinical problem as it arose. Their constant focus on the clinical goal aided the rapid transformation of their design from a leaflet valve to a shielded ball valve, and finally to an unshielded ball valve suitable for implantation in a human being. Along the way, they abandoned the idea of imitating the appearance of native valves, in favor of developing valves that would be clinically successful. Their work has provided help and hope for patients who otherwise would have died from the complications of rheumatic heart disease and other valvular disorders for which valve replacement is the only treatment. Images PMID:9885105

  4. Salutary swan song for the Starr Edwards valve.

    PubMed

    Masilonyane-Jones, Taolo Vijay; Blackham, Ruth; Alvarez, John

    2010-07-01

    The Starr-Edwards valve was the first manufactured valve to be used successfully as a cardiac valve replacement in 1960. Although superseded by newer valves over the decades it has achieved an excellent track record. It has unique features, namely a protective metal casing around the ball poppet and a large and thick sewing ring. We describe the last implant of this valve in Australia; it has now been withdrawn by the manufacturer. In this particular case, the unique features of this valve made the required surgery quite simple and avoided the need for complex mitral valve surgery in a very high-risk patient.

  5. Malfunctioning Starr-Edwards mitral valve 21 years after installation.

    PubMed

    Sakata, K; Ishikawa, S; Ohtaki, A; Otani, Y; Suzuki, M; Kawashima, O; Morishita, Y

    1997-02-01

    Two cases of malfunctioning Starr-Edwards cloth-covered mitral valve prostheses requiring reoperation are presented. Both cases underwent successful surgical repair 21 years after the valve replacement. The causes were a disturbance of the poppet during the opening movement due to excessive tissue ingrowth and a paravalvular leak associated with a tear of the valve seat. Replacement of the Starr-Edwards valve prosthesis more than 20 years after the initial installation has not been reported.

  6. Haemolysis with Björk-Shiley and Starr-Edwards prosthetic heart valves: a comparative study

    PubMed Central

    Slater, S. D.; Sallam, I. A.; Bain, W. H.; Turner, M. A.; Lawrie, T. D. V.

    1974-01-01

    Slater, S. D., Sallam, I. A., Bain, W. H., Turner, M. A., and Lawrie, T. D. V. (1974).Thorax, 29, 624-632. Haemolysis with Björk-Shiley and Starr-Edwards prosthetic heart valves: a comparative study. A comparison was made of the haemolytic complications in 85 patients with two different types of Starr-Edwards cloth-covered ball and cage prosthesis with those in 44 patients with the Björk-Shiley tilting disc valve. Intravascular haemolysis, as detected by the presence of haemosiderinuria, occurred significantly less often with the Björk-Shiley than with the Starr-Edwards valve, the overall incidence with aortic, mitral or multiple replacements being 31%, 15%, and 20% for Björk-Shiley and 94%, 92%, and 88% for Starr-Edwards valves respectively. There was no significant difference in the frequency of haemolysis between each of the two types of Starr-Edwards prosthesis studied at either the aortic (2300 versus 2310 model) or mitral (6300 versus 6310) site. Haemolytic anaemia developed in only one patient with a Björk-Shiley valve but was common though usually mild with Starr-Edwards prostheses, particularly aortic valve replacements with the 2300 model and in aortic plus mitral (± tricuspid) replacements. The greater severity of haemolysis produced by Starr-Edwards valves, again especially of the latter types, was further demonstrated by higher serum lactate dehydrogenase and 24-hour urinary iron levels. It is concluded that the Björk-Shiley tilting disc valve represents a significant advance in the amelioration of the haemolytic complications of prosthetic valves. PMID:4450173

  7. Ten year clinical evaluation of Starr-Edwards 2400 and 1260 aortic valve prostheses.

    PubMed Central

    Hackett, D; Fessatidis, I; Sapsford, R; Oakley, C

    1987-01-01

    The long term performance characteristics of the 2400 and 1260 series of Starr-Edwards aortic prostheses were investigated by a follow up study of clinical outcome of 327 patients discharged from hospital with isolated aortic valve replacement. Follow up lasted for up to 10 years and was based on 1616 patient-years. The 2400 series cloth covered tracked valve was implanted in 182 patients from 1974 to 1980 and the 1260 series bare strut silastic ball valve was inserted in 145 patients from 1979 to 1983. Total 10 year mortality and valve related morbidity were low and no cases of mechanical valve failure were recorded. There were no significant actuarial differences in mortality or valve related morbidity between the 2400 and 1260 valves. Starr-Edwards models 2400 and 1260 aortic valve prostheses showed excellent durability without any mechanical failures over a 10 year period. The long term outcome of isolated aortic valve replacement with these models is associated with a low frequency of valve related complications. PMID:3580223

  8. Prosthetic Valve Dysfunction 35 Years after Mitral Valve Replacement with a Starr-Edwards Caged-disc Valve.

    PubMed

    Yokokawa, Tetsuro; Ohara, Takahiro; Takashio, Seiji; Sakamoto, Mari; Wada, Yuko; Nakamura, Kenji; Takahama, Hiroyuki; Amaki, Makoto; Hasegawa, Takuya; Sugano, Yasuo; Kanzaki, Hideaki; Yasuda, Satoshi; Ogawa, Hisao; Fujita, Tomoyuki; Kobayashi, Junjiro; Okamoto, Yoko; Matsuyama, Taka-Aki; Ishibashi-Ueda, Hatsue; Anzai, Toshihisa

    2016-01-01

    A 49-year-old man was admitted to our hospital with a chief complaint of dyspnea. He had a history of mitral valve replacement (MVR) with a Starr-Edwards (SE) caged-disc valve at the age of 14. Echocardiography revealed elevated trans-valvular pressure gradient of the mitral prosthetic valve with neither disk motion abnormality nor abnormal structure. Catheterization confirmed an elevation of the mean diastolic gradient of the mitral valve to 12.3 mmHg. Re-MVR was performed, and abnormal tissue attached to the cage of the valve and proliferating beneath the valve was observed. Histologic examination revealed them as fibrinous tissue and mild pannus proliferation, respectively. This rare case report focuses on long-term follow-up and the complication of a SE caged-disc valve. A SE caged-disc valve may become stenotic, only detected with a trans-valvular pressure gradient without any disk motion abnormality or abnormal structure during a prolonged follow-up period.

  9. Thirty-Seven-Year Durability of a Starr-Edwards Aortic Prosthesis

    PubMed Central

    Ozkokeli, Mehmet; Ates, Mehmet; Ekinci, Abdurrahman; Akcar, Murat

    2005-01-01

    We report the case of a patient who was diagnosed with prosthetic valve endocarditis caused by Staphylococcus aureus. He had undergone aortic valve replacement with a Starr-Edwards prosthesis 37 years earlier. Because of uncontrolled infection despite antibiotic treatment, the patient underwent successful surgical replacement of the prosthetic valve. PMID:15902834

  10. Transfemoral implantation of CoreValve Evolut-R aortic prosthesis in patient with prior ball-cage mechanical mitral valve prosthesis.

    PubMed

    Maluenda, Gabriel; Caorsi, Carlos; Baeza, Cristian

    2016-06-01

    Transcatheter aortic valve replacement remains challenge in patients with ball-cage-type mechanical valve in mitral position. Potential under-expansion of the percutaneous valve and interaction between the mitral ball-cage mechanical valve tilted towards the left ventricular outflow tract and the percutaneous valve adds risk during and after implantation. We report a successful implantation of the novel CoreValve Evolut-R self-expanding in a patient with severe aortic stenosis and a mitral Starr-Edwards mechanical valve implanted 28years ago.

  11. Cloth destruction and haemolysis with totally cloth-covered Starr-Edwards prostheses

    PubMed Central

    Schottenfeld, M.; Wisheart, J. D.; Ross, J. K.; Lincoln, J. C. R.; Ross, D. N.

    1971-01-01

    Four cases are described in which totally cloth-covered Starr-Edwards valves (model 2300) had to be removed. All were causing significant haemolysis, two in the absence of a peripheral leak. The principal operative finding was destruction of the Dacron covering the struts. Following replacement of these prostheses there was complete resolution of signs and symptoms. The possible causes of haemolysis and consequences of cloth destruction are discussed. Images PMID:5576531

  12. Ball valve extractor

    DOEpatents

    Herndon, Charles; Brown, Roger A.

    2002-01-01

    An apparatus and process for removing a ball valve is provided. The ball valve removal tool provides a handle sliding along the length of a shaft. One end of the shaft is secured within an interior cavity of a ball valve while the opposite end of the shaft defines a stop member. By providing a manual sliding force to the handle, the handle impacts the stop member and transmits the force to the ball valve. The direction of the force is along the shaft of the removal tool and disengages the ball valve from the ball valve housing.

  13. Long-term follow-up of cloth-covered Starr-Edwards prostheses.

    PubMed

    Carey, J S

    1976-05-01

    One hundred patients in whom cloth-covered Starr-Edwards prostheses were implanted have now been followed for 3 to 7 years. The hospital mortality rate was 5 per cent, and survival at five years was 70 per cent. Complications related to valve design occurred in 8 per cent (4 per cent fatal). The majority of late deaths and poor results were related to progressive cardiac disease rather than valve-related complications. The results indicate that cloth-covered prostheses have significantly lowered the incidence of thromboembolism and eliminated poppet dysfunction. The problem of strut cloth wear was clinically observed only twice in 500 patient-years of follow-up.

  14. Thrombo-embolic complications of the cloth-covered Starr-Edwards prostheses No. 2300 aortic and No. 6300 mitral

    PubMed Central

    Cleland, J.; Molloy, P. J.

    1973-01-01

    The thrombo-embolic complications of the cloth-covered Starr-Edwards prostheses No. 2300 aortic and No. 6300 mitral followed for an average of 14 months in 155 patients are reviewed. There was a high incidence of early fatal and disabling thrombo-embolus in patients having mitral valve replacement. Late emboli were more common after aortic valve replacement. Anticoagulant control was unsatisfactory and not without hazards. PMID:4685210

  15. Fractured occluder disc: a previously unrecognized complication of the Starr-Edwards disc prosthesis.

    PubMed

    Malouf, J F; Hannoush, H M; Odell, J A

    2001-01-01

    Fracture of the occluder disc of a low-profile Starr-Edwards prosthesis is a hitherto unrecognized complication. We describe a patient who presented with right heart failure and severe pulmonary hypertension 27 years after mitral valve replacement with a model 6520 caged-disc prosthesis. At surgery, there was a longitudinal split in the occluder disc, and organized thrombus was lodged between the split segments. This case offers a unique opportunity to study the long-term effects of wear on the polyethylene poppet and Stellite cage.

  16. Preserving a Well-Functioning 33-Year-Old Starr-Edwards Aortic Prosthesis in Repeat Aortic Root Aneurysm Repair

    PubMed Central

    Alimov, Victor K.; Rousou, John A.; Pluchino, Fabrizio I.

    2016-01-01

    We report the case of a 61-year-old obese male patient in whom we found a well-functioning 33-year-old Starr-Edwards aortic prosthesis during repeat aortic surgery. Rather than explant the prosthesis, we remodeled the aortic root, almost completely removing the aortic sinuses and leaving only a pillar of aortic tissue around the coronary ostia. The proximal end of a Hemashield tube-graft was then scalloped to accommodate the remaining aortic tissue. The patient's heart function was excellent after his weaning from cardiopulmonary bypass. Simplifying the repeat aortic root repair, by preserving a well-functioning Starr-Edwards valve, might lead to a better outcome in similar cases. We also discuss other instances of this valve's durability. PMID:28100977

  17. Quartz ball valve

    NASA Technical Reports Server (NTRS)

    Goetz, C.; Ingle, W. M. (Inventor)

    1980-01-01

    A ball valve particularly suited for use in the handling of highly corrosive fluids is described. It is characterized by a valve housing formed of communicating segments of quartz tubing, a pair of communicating sockets disposed in coaxial alignment with selected segments of tubing for establishing a pair of inlet ports communicating with a common outlet port, a ball formed of quartz material supported for displacement between the sockets and configured to be received alternately thereby, and a valve actuator including a rod attached to the ball for selectively displacing the ball relative to each of the sockets for controlling fluid flow through the inlet ports.

  18. Diastolic murmurs in the presence of Starr-Edwards mitral prosthesis.

    PubMed

    Schaffer, R A; McAnulty, J H; Starr, A; Rahimtoola, S H

    1975-03-01

    Diastolic murmurs associated with the Starr-Edwards mitral prosthesis have not been described previously. In this report, five patients with mitral prostheses are described in whom apical mid-diastolic and presystolic murmurs resulted from two different causes. Three patients had clots obstructing the prosthetic orifice. The other two had normally functioning protheses and moderately severe aortic insufficiency. The occurrence of mid-diastolic and presystolic murmurs in the presence of a normally functioning prosthetic mitral valve demonstrates that 1) the mid-diastolic Austin Flint murmur can occur in the absence of incomplete mitral valve opening, premature mitral valve closure, vibrating mitral leaflets, or relative mitral stenosis and 2) the presystolic Austin Flint murmur can occur in the absence of incomplete valve opening or presystolic mitral regurgitation. However, the presystolic murmur was associated with early closure movement of the presthetic poppet.

  19. Stemless Ball Valve

    NASA Technical Reports Server (NTRS)

    Burgess, Robert K.; Yakos, David; Walthall, Bryan

    2012-01-01

    This invention utilizes a new method of opening and closing a ball valve. Instead of rotating the ball with a perpendicular stem (as is the case with standard ball valves), the ball is rotated around a fixed axis by two guide pins. This innovation eliminates the leak point that is present in all standard ball valves due to the penetration of an actuation stem through the valve body. The VOST (Venturi Off-Set-Technology) valve has been developed for commercial applications. The standard version of the valve consists of an off-set venturi flow path through the valve. This path is split at the narrowest portion of the venturi, allowing the section upstream from the venturi to be rotated. As this rotation takes place, the venturi becomes restricted as one face rotates with respect to the other, eventually closing off the flow path. A spring-loaded seal made of resilient material is embedded in the upstream face of the valve, making a leak-proof seal between the faces; thus a valve is formed. The spring-loaded lip seal is the only seal that can provide a class six, or bubble-tight, seal against the opposite face of the valve. Tearing action of the seal by high-velocity gas on this early design required relocation of the seal to the downstream face of the valve. In the stemless embodiment of this valve, inner and outer magnetic cartridges are employed to transfer mechanical torque from the outside of the valve to the inside without the use of a stem. This eliminates the leak path caused by the valve stems in standard valves because the stems penetrate through the bodies of these valves.

  20. Stemless ball valve

    NASA Technical Reports Server (NTRS)

    Burgess, Kevin (Inventor); Yakos, David (Inventor); Walthall, Bryan (Inventor)

    2011-01-01

    A stemless ball valve comprising two flanges and a ball with a channel, two axis pins and two travel pins. One end of each axis and travel pin is fixedly attached to the ball, and the other end of each axis pin is lodged into a notch in the first or second flange such that the axis pin is allowed to rotate in the notch. The guide sleeve comprises two channels, and one end of each travel pin is situated within one of the two channels in the guide sleeve. An outer magnetic cartridge causes the inner magnetic cartridge and guide sleeve to rotate, and when the guide sleeve rotates, the travel pins move up and down within the channels in the guide sleeve. The movement of the travel pins within the channels in the guide sleeve causes the ball to rotate, thereby opening and closing the ball valve.

  1. Stemless ball valve

    NASA Technical Reports Server (NTRS)

    Burgess, Kevin (Inventor); Yakos, David (Inventor); Walthall, Bryan (Inventor)

    2012-01-01

    A stemless ball valve comprising: a right flange; left flange; ball with an axis pin and two travel pins; ball seal on either side of the ball; guide sleeve with inner walls comprising two channels; cartridge guide holder; inner magnetic cartridge; and outer magnetic cartridge. The ball is situated inside of the guide sleeve, and a travel pin is located in each of the two channels. The guide sleeve is situated inside of the cartridge guide holder, which is located adjacent to and outside of the inner magnetic cartridge and secured to the inner magnetic cartridge such that when the inner magnetic cartridge rotates, the cartridge guide holder also rotates. The cartridge guide holder is secured to the guide sleeve such that when the cartridge guide holder rotates, the travel pins move within the channels in the inner walls of the guide sleeve, thereby causing the ball to rotate.

  2. Ball valve safety screen

    SciTech Connect

    Bolding, B.H.

    1981-09-01

    A device for preventing unwanted objects from entering the ball assembly of a float collar or float shoe and otherwise damaging or plugging the valve mechanism therein is disclosed. The device comprises a screen constructed of expanded metal and rigidly affixed to the interior of the float collar or float shoe above the ball valve assembly. The screen portion is either mounted to the interior surface of the float collar sleeve by an annular structural member or mounted to a structural band which is partially embedded in the concrete portion of the float collar or casing guide shoe.

  3. Late entrapment of ball and cage valve in mitral position.

    PubMed

    Akbari, Jayesh G; Varma, Praveen K; Gadhinglajkar, Shrinivas V; Neelakandhan, Kurur S

    2006-02-01

    A 32-year-old female underwent mitral valve replacement with total chordal preservation (Miki's technique) using 26 mm (1M) Starr-Edward prosthesis (SEP) in 1988. The patient was in NYHA class-I until 2001. She progressed to NYHA class-III with paroxysmal nocturnal dyspnoea. Transthoracic echocardiogram showed increased prosthetic valve gradient, and cardiac catheterization confirmed the findings. Intraoperatively, the poppet movement in the cage was found to be restricted due to the preserved subvalvular apparatus entrapping the poppet inside the prosthetic valve cage.

  4. Phonocardiographic diagnosis of aortic ball variance.

    PubMed

    Hylen, J C; Kloster, F E; Herr, R H; Hull, P Q; Ames, A W; Starr, A; Griswold, H E

    1968-07-01

    Fatty infiltration causing changes in the silastic poppet of the Model 1000 series Starr-Edwards aortic valve prostheses (ball variance) has been detected with increasing frequency and can result in sudden death. Phonocardiograms were recorded on 12 patients with ball variance confirmed by operation and of 31 controls. Ten of the 12 patients with ball variance were distinguished from the controls by an aortic opening sound (AO) less than half as intense as the aortic closure sound (AC) at the second right intercostal space (AO/AC ratio less than 0.5). Both AO and AC were decreased in two patients with ball variance, with the loss of the characteristic high frequency and amplitude of these sounds. The only patient having a diminished AO/AC ratio (0.42) without ball variance at reoperation had a clot extending over the aortic valve struts. The phonocardiographic findings have been the most reliable objective evidence of ball variance in patients with Starr-Edwards aortic prosthesis of the Model 1000 series.

  5. Whitey SCHe Ball Valves Provide Test Port Isolation

    SciTech Connect

    MISKA, C.R.

    2000-09-15

    These valves are 1/4 inch ball valves fabricated of 316 stainless steel. Packing is TFE (standard). They are used as normally closed isolation valves for test ports in the SCHe System between the gage root valve and the pressure indicator.

  6. Acute tricuspid valve obstruction following the use of tricuspid ball valve prosthesis

    PubMed Central

    Samaan, H. A.; Murali, R.

    1970-01-01

    A case is presented in which the mitral and tricuspid valves were replaced by a ball-valve prosthesis. The patient was admitted as an emergency 18 months later with the clinical picture of acute venous inflow obstruction to the heart due to tricuspid ball-valve prosthesis obstruction. Successful replacement under emergency open heart surgery, using assisted circulation, is described. Images PMID:5452288

  7. 16. DETAIL SHOWING LIQUID OXYGEN TANK FOURTEENINCH BALL VALVE. Looking ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    16. DETAIL SHOWING LIQUID OXYGEN TANK FOURTEEN-INCH BALL VALVE. Looking southwest. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  8. 17. DETAIL, FOURTEENINCH LIQUID OXYGEN BALL VALVE. Looking south southeast. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    17. DETAIL, FOURTEEN-INCH LIQUID OXYGEN BALL VALVE. Looking south southeast. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  9. Echocardiographic features of aortic ball valve prosthesis malfunction.

    PubMed

    Weisburst, M R; Singh, A K; Riley, R S

    1982-11-01

    A case of aortic ball valve prosthesis malfunction is described in which the poppet became alternately stuck in the open and closed position. The patient experienced chest pain followed by pulmonary edema and cardiac arrest. Malfunction of prosthetic valve was diagnosed on echocardiogram and cardiopulmonary resuscitation was carried out until a Bjork-Shiley valve could be inserted in place of the faulty prosthesis. At the time of the operation, poppet migration had occurred and the poppet could not be found. Subsequent Bjork-Shiley aortic valve prosthesis dysfunction was suggested by variation in the intensity of the aortic opening sound and in the duration of the systolic ejection period. Fluoroscopy revealed the missing poppet in the left ventricle. Following surgical removal of the poppet, "normal" Bjork-Shiley valve function was restored.

  10. Ball valve design for solid withdrawal service in coal liquefaction

    NASA Astrophysics Data System (ADS)

    Patton, Alexander J.

    1981-02-01

    Valves used for drawdown of the solids produced in the coal liquefaction process must be designed to operate at high temperatures and must prevent the buildup of solids within the valve internals to insure operability. Consideration must also be given to materials used for seating surfaces in terms of being able to withstand abrasion. Research into the design and materials for this application results in a new ball valve design with a special inlet port liner and O-ring seal. A prototype valve was built and put in service in a small scale, experimental coal liquefaction plant. For comparative purposes a standard design valve was also used, with both valves being subjected to over 1000 open/close cycles, after which both valves were removed, tested, and disassembled for inspection. The results of this experimental program will be presented, including process parameters, service conditions, and material evaluation. Particular emphasis will be placed on wear of seating surfaces and the effects of process material on the physical properties of seal and packing materials.

  11. A magnetically driven PDMS micropump with ball check-valves

    NASA Astrophysics Data System (ADS)

    Pan, Tingrui; McDonald, Scott J.; Kai, Eleanor M.; Ziaie, Babak

    2005-05-01

    In this paper, we present a low-cost, PDMS-membrane micropump with two one-way ball check-valves for lab-on-a-chip and microfluidic applications. The micropump consists of two functional PDMS layers, one holding the ball check-valves and an actuating chamber, and the other covering the chamber and holding a miniature permanent magnet on top for actuation. An additional PDMS layer is used to cover the top magnet, and thereby encapsulate the entire device. A simple approach was used to assemble a high-performance ball check-valve using a micropipette and heat shrink tubing. The micropump can be driven by an external magnetic force provided by another permanent magnet or an integrated coil. In the first driving scheme, a small dc motor (6 mm in diameter and 15 mm in length) with a neodymium-iron-boron permanent magnet embedded in its shaft was used to actuate the membrane-mounted magnet. This driving method yielded a large pumping rate with very low power consumption. A maximum pumping rate of 774 µL min-1 for deionized water was achieved at the input power of 13 mW, the highest pumping rate reported in the literature for micropumps at such power consumptions. Alternatively, we actuated the micropump with a 10-turn planar coil fabricated on a PC board. This method resulted in a higher pumping rate of 1 mL min-1 for deionized water. Although more integratable and compact, the planar microcoil driving technique has a much higher power consumption.

  12. Space Shuttle Orbital Maneuvering Subsystem (OMS) Engine Propellant Leakage Ball-Valve Shaft Seals

    NASA Technical Reports Server (NTRS)

    Lueders, Kathy; Buntain, Nick; Fries, Joseph (Technical Monitor)

    1999-01-01

    Evidence of propellant leakage across ball-valve shaft seals has been noted during the disassembly of five flight engines and one test engine at the NASA Lyndon B. Johnson Space Center, White Sands Test Facility. Based on data collected during the disassembly of these five engines, the consequences of propellant leakage across the ball-valve shaft seals can be divided into four primary areas of concern: Damage to the ball-valve pinion shafts, damage to sleeved bearings inside the ball-valve and actuator assemblies, degradation of the synthetic rubber o-rings used in the actuator assemblies, and corrosion and degradation to the interior of the actuator assemblies. The exact time at which leakage across the ball-valve shaft seals occurs has not been determined, however, the leakage most likely occurs during engine firings when, depending on the specification used, ball-valve cavity pressures range as high as 453 to 550 psia. This potential pressure range for the ball-valve cavities greatly exceeds the acceptance leakage test pressure of 332 psia. Since redesign and replacement of the ball-valve shaft seals is unlikely, the near term solution to prevent damage that occurs from shaft-seal leakage is to implement a routine overhaul and maintenance program for engines in the fleet. Recommended repair, verification, and possible preventative maintenance measures are discussed in the paper.

  13. Space Shuttle Orbital Maneuvering Subsystem (OMS) Engine Propellant Leakage Ball-Valve Shaft Seals

    NASA Technical Reports Server (NTRS)

    Lueders, Kathy; Buntain, Nick; Fries, Joseph (Technical Monitor)

    1999-01-01

    Evidence of propellant leakage across ball-valve shaft seals has been noted during the disassembly of five flight engines and one test engine at the NASA Lyndon B. Johnson Space Center, White Sands Test Facility. Based on data collected during the disassembly of these five engines, the consequences of propellant leakage across the ball-valve shaft seals can be divided into four primary areas of concern: Damage to the ball-valve pinion shafts, damage to sleeved bearings inside the ball-valve and actuator assemblies, degradation of the synthetic rubber o-rings used in the actuator assemblies, and corrosion and degradation to the interior of the actuator assemblies. The exact time at which leakage across the ball-valve shaft seals occurs has not been determined, however, the leakage most likely occurs during engine firings when, depending on the specification used, ball-valve cavity pressures range as high as 453 to 550 psia. This potential pressure range for the ball-valve cavities greatly exceeds the acceptance leakage test pressure of 332 psia. Since redesign and replacement of the ball-valve shaft seals is unlikely, the near term solution to prevent damage that occurs from shaft-seal leakage is to implement a routine overhaul and maintenance program for engines in the fleet. Recommended repair, verification, and possible preventative maintenance measures are discussed in the paper.

  14. Valvular Hemolysis Masquerading as Prosthetic Valve Stenosis.

    PubMed

    Sethi, Pooja; Murtaza, Ghulam; Rahman, Zia; Zaidi, Syed; Helton, Thomas; Paul, Timir

    2017-04-08

    The evaluation of prosthetic valves can provide a unique challenge, and a thoughtful approach is required. High output states like anemia should be kept in the differential when evaluating elevated gradients across prosthetic valves. We present the case of a 69-year-old man with a Starr-Edwards prosthetic aortic valve who presented with symptoms of congestive heart failure and high transvalvular pressure gradients. These symptoms indicate a potential prosthetic valve stenosis. His laboratory evaluation results were consistent with valve-related hemolysis. Resolving his anemia led to a resolution of the symptoms and lowered the pressure gradient on follow-up.

  15. [Ball variance and fracture of a Smeloff-Cutter prosthesis 24 years after aortic valve replacement].

    PubMed

    Hust, M H; Klinkmüller, A; Keim, M; Momper, R; Nothwang, G

    1997-07-01

    This report documents a case of ball variance in a Smeloff-Cutter aortic prosthesis occurring 24 years after implantation. After episodes of embolic complications the patient died in acute shock. The silicone rubber ball showed several alterations including discoloration, grooving, cracking, swelling and subtotal fracture of the poppet. Terminal valvular malfunction was caused by complete thrombosis of the prosthesis. In most patients ball variance occurred during the first years after valve replacement; thus, the observed case is a very rare late complication of a ball-valve prosthesis.

  16. [Doppler echocardiography in assessing mechanical and biological heart valve prostheses].

    PubMed

    Minardi, G; Di Segni, M; Boccardi, L; Ferrari, O; Giovannini, E

    1988-02-01

    The study was performed to assess Doppler echocardiographic features of mitral and aortic prosthetic valves of different types with both normal and abnormal function. Two hundred and twenty-three patients with 250 prostheses were studied. Two hundred eight valves (111 mitral, 95 aortic and 2 tricuspid) were considered to be functioning normally after clinical examination, phonocardiography and M-mode and 2D echocardiography. This group enabled us to define normal Doppler echocardiographic findings for different types of prosthesis. In mitral position, peak (p) and mean (m) gradients were lower for disc prostheses and higher for ball and biological prosthetic valves; values of effective orifice area (A), calculated by pressure half-time method, were lower for biological and ball prostheses and higher in disc valves. Results were as follows: St. Jude (p 10.6 mmHg, m 3.9 mmHg, A 2.7 cm2), Duromedics (p 10.6, m 4.3, A 2.8), Björk-Shiley (p 10.4, m 4, A 2.3), Omniscience (p 14.2, m 6.2, A 2.1), Starr-Edwards (p 15.9, m 5.4, A 2.1), Hancock (p 14.7, m 6, A 2), Carpentier (p 13.2, m 5.4, A 1.9). Mild regurgitation, considered "physiological", was found in 2/8 Carpentier valves and in 3/34 St. Jude prostheses. In aortic valves lower peak gradients were found in Lillehei (18.3 mmHg), St. Jude (23.8 mmHg), Björk-Shiley (26 mmHg), Duromedics (27 mmHg) and higher values in Starr-Edwards (30.2 mmHg), Hancock (30 mmHg) and Omniscience (35.5 mmHg) prostheses. Mild regurgitation, considered "physiological", was found in 17% of Omniscience valves, 21% of Hancock, 33% of Duromedics, 45% of St. Jude, 60% of Björk-Shiley prostheses. Hancock mitral valves implanted for over 7 years had a mean gradient higher than valves with a shorter period of implantation (7.6 vs 4.85 mmHg, p less than 0.1), whereas the effective orifice area was similar. Hancock aortic valves implanted for over 7 years had a peak gradient slightly higher than the other group (implantation less than 7 years

  17. Failure analyses of two ball valves used for coal-gasification applications

    SciTech Connect

    Van Den Avyle, J.A.; Pope, L.E.

    1982-07-01

    Two ball valves which had failed by developing excess leakage were supplied for analyses. The 2'' (51 mm) valve had experienced 5000 cycles during 20 hrs usage in an unknown chemical environment. Wear on the ball and seats was a multi-stage process starting with breakdown of a hard chrome plating on the stainless steel ball. This eventually led to adhesive weld transfer of the stainless steel to the seat made of Stellite 6 alloy. The 6'' (152 mm) ball valve had experienced a cycling test sequence using compressed air up to 300 psig (2.07 MPa) at 850/sup 0/F (727/sup 0/K). Damage was characterized as abrasive wear caused either by particles deposited by the compressed air or by carbide particles present in the Stellite 6 alloy ball and seat hardfacing. The decrease in this alloy's compressive yield strength at the elevated test temperature contributed to increased wear rates.

  18. Metal seated ball valves for the flow control of abrasive fluids

    SciTech Connect

    Harrison, M.J.

    1997-07-01

    Until recent times the only acceptable valves for use in medium to high pressure slurry pipelines had been Knife Gate Valves and Lubricated Plug Valves. Both of these types of valves have their own inherent problems. Knife Gate Valves are limited by operating pressure, temperature limits, seat tightness, ease of operation and automation. Lubricated Plug Valves are limited by the constant need for sealant injection, high maintenance, high cost, elevated temperatures and reduced through-put, due to the rectangular port design. Attempts have been made to utilize modified versions of the traditional oil and gas ball valve for use in abrasive fluids and many manufacturers are capable of producing a metal seated version. This metal seated valve is a modification of a soft seated API 6D trunnion mounted ball valve, designed primarily for water, oil and gas services. This modified valve is comparatively inexpensive and although it can function well with small amounts of solids in the flowing media, it cannot survive the tortures of cycling in medium and high pressure abrasive fluids, or at high differential pressures. This type of valve utilizes a pressure assisted or {open_quotes}dynamic seal{close_quotes} on both sides of the ball. These pressure assisted seals are generally made ineffective by the ingress of solid particles.

  19. Free-floating left atrial ball thrombus early after mitral valve replacement.

    PubMed

    Sanae, T; Kazama, S; Nie, M; Miyoshi, Y; Machii, M; Ohara, K; Yoshimura, H

    2000-12-01

    A 61-year-old woman was found to have a free-floating ball, thrombus in the left atrium on echocardiographic examination 2 weeks after mitral valve replacement and tricuspid, annuloplasty. The free-floating thrombus was successfully, removed by an open-heart procedure without clinical sequelae. The diagnostic value of routine echocardiography on follow-up of valve surgery is emphasized.

  20. The unnatural history of valvular heart disease: late results with silastic ball valve prostheses.

    PubMed

    Freimanis, I; Starr, A

    1984-01-01

    The development of prosthetic heart valves successfully arrested the dismal natural history of valvular heart disease for thousands of patients. The experiences of numerous investigators provided a setting wherein the design and implantation of the silastic ball valves led to improved survival with both aortic and mitral valve replacement. Refinement of the caged-ball design was based on clinical and laboratory findings. In the mitral position, valve related thromboembolism was reduced from 38% to 3%. With the aortic prostheses the problem of ball variance was overcome by reducing trauma to the poppet and altering its heat curing process. In 1967 a completely cloth covered valve was introduced to reduce further the thromboembolic rate. Significant improvement in the embolus-free rate was ultimately found to be dependent on the year of operation with introduction of the time-frame concept. The current mitral silastic ball valve, Model 6120, yields an actuarial survival of 72 (+/- 3%), 54 (+/- 5%), and 37 (+/- 5%) for five, ten and fifteen years respectively. For aortic valve replacement, current Model 1260, the actuarial survival is 71 (+/- 2%), 58 (+/- 3%) and 48 (+/- 4%) for five, ten and fifteen years respectively. Late results are compared to other valvular prostheses.

  1. Downhole tool for use with a ball and seat traveling valve for a fluid pump

    SciTech Connect

    Spears, H.L.

    1989-07-18

    This paper describes a downhole tool for use with a ball and seat travelling valve associated with a movable plunger, having upper and lower ends, for pumping well fluids. It comprises: an upper housing; a lower housing adapted to be associated with the upper end of the plunger; and means for causing relative movement between the upper and lower housings and abutment of the upper housing against the lower housing to impart a bumping force to the plunger during the downward movement of the plunger, whereby the ball is moved from its seat to permit the passage of well fluids through the travelling valve.

  2. System for remotely servicing a top loading captive ball valve

    DOEpatents

    Berry, Stephen M.; Porter, Matthew L.

    1996-01-01

    An attachment for facilitating servicing of a valve, the valve including: an assembly composed of a valve seat defining a flow path, a flow control member movable relative to the valve seat for blocking or unblocking the valve seat, and a control device including a stem coupled to the flow control member and operable for moving the flow control member relative to the valve seat; a housing for receiving the assembly, the housing having an opening via which the assembly can be removed from, and installed in, the housing, and the housing having a plurality of threaded studs which surround the opening and project away from the housing; a valve housing cover for closing and sealing the opening in the housing, the cover having a first bore for passage of the stem of the control device when the assembly is installed in the housing and a plurality of second bores each located for passage of a respective stud when the cover closes the opening in the housing. A plurality of threaded nuts are engageable with the studs for securing the cover to the housing when the cover closes the opening in the housing, wherein the attachment comprises: a plurality of nut guide devices removable from the housing and each operatively associated with a respective stud for retaining a respective nut and guiding the respective nut into alignment with the respective stud to enable the respective nut to be rotated into engagement with the respective stud; and aligning the nut guide devices with the studs.

  3. System for remotely servicing a top loading captive ball valve

    DOEpatents

    Berry, S.M.; Porter, M.L.

    1996-06-25

    An attachment for facilitating servicing of a valve is disclosed including: an assembly composed of a valve seat defining a flow path, a flow control member movable relative to the valve seat for blocking or unblocking the valve seat, and a control device including a stem coupled to the flow control member and operable for moving the flow control member relative to the valve seat; a housing for receiving the assembly, the housing having an opening via which the assembly can be removed from, and installed in, the housing, and the housing having a plurality of threaded studs which surround the opening and project away from the housing; a valve housing cover for closing and sealing the opening in the housing, the cover having a first bore for passage of the stem of the control device when the assembly is installed in the housing and a plurality of second bores each located for passage of a respective stud when the cover closes the opening in the housing. A plurality of threaded nuts are engageable with the studs for securing the cover to the housing when the cover closes the opening in the housing, wherein the attachment comprises: a plurality of nut guide devices removable from the housing and each operatively associated with a respective stud for retaining a respective nut and guiding the respective nut into alignment with the respective stud to enable the respective nut to be rotated into engagement with the respective stud; and aligning the nut guide devices with the studs. 7 figs.

  4. A characteristic analysis of high pressure and high temperature 3-way ball valve

    NASA Astrophysics Data System (ADS)

    Lee, Joon Ho; Jeon, Rock Won; Kim, Si Pom; Lee, Jae Hun; Lee, Jae Hoon

    2012-11-01

    Ball valves have been mostly used for high temperature/high pressure valves using in petrochemical carriers and oil tankers being built in Korea, which requires high quality products with confidentiality and durability. As a larger disaster may be generated by leakage of oil or gas from valves, thus the present research applied a numerical analysis method on thermal stress distribution and deformation, etc. In addition, the present research compared the performance test result with numerical analysis results. The Max stress by parts was confirmed through thermal-structural coupled field analysis of major parts to evaluate safety. And its performance was verified by carrying out the durability and leakage test for the manufactured valves.

  5. Whitey Swagelok SCHe ball valves Provide Isolation between SCHe Purge Lines C and D and the Process Vent

    SciTech Connect

    MISKA, C.R.

    2000-09-03

    These valves are 1/4 inch ball valves fabricated of 316 stainless steel. Packing is TFE (standard). They provide an isolation function betwen SCHe Purge Line C, (PV-V-*079), and Purge Line D, (PV-V-*080), and the Process Vent.

  6. Whitey Swagelok SCHe Ball Valves Provide Isolation between SCHe Purge Lines C and D and the Process Vent

    SciTech Connect

    MISKA, C.R.

    2000-09-15

    These valves are 1/4 inch ball valves fabricated of 316 stainless steel. Packing is TFE (standard). They provide an isolation function betwen SCHe Purge Line C, (PV-V-*079), and Purge Line D, (PV-V-*080), and the Process Vent.

  7. Whitey Swagelok SCHe Ball Valves Provide Isolation between SCHe Purge Lines C and D and the Process Vent

    SciTech Connect

    VAN KATWIJK, C.

    2000-06-21

    These valves are 1/4 inch ball valves fabricated of 316 stainless steel. Packing is TFE (standard). They provide an isolation function between SCHe Purge Line C, (PV-V-*079), and Purge Line D, (PV-V-*080), and the Process Vent.

  8. Excessive strut wear allowing ball-poppet embolization in a DeBakey-Surgitool aortic valve prosthesis.

    PubMed

    Sutherland, R D; Guynes, W A; Nichols, C T; Martinez, H E

    1982-01-01

    Excessive cage strut wear allowing ball-poppet embolization caused the sudden death of a 47 year old lady in whom a DeBakey-Surgitool aortic prosthesis had been implanted nine years earlier. Patients with this type of prosthesis should have periodic valvular cine fluoroscopy with image intensification to allow visualization of significant strut wear or fracture, and appropriate prosthetic valve replacement.

  9. Basaloid Squamous Cell Carcinoma: An Unusual Ball-Valve Laryngeal Obstruction

    PubMed Central

    Tan, Sien Hui; Hindi, Khalid W; Chandran, Patricia Ann; Chong, Aun Wee

    2015-01-01

    Introduction: A rare case of basaloid squamous cell carcinoma (BSCC) of the larynx, which has not been previously reported, is described. Case Report: A 60-year-old man was presented to the Otolaryngology Department with progressive dyspnoea and dysphagia to solids for over a period of 1 week. Direct laryngoscopy revealed a tumour at the laryngeal aspect of the epiglottis, which prolapsed into the laryngeal inlet each time the patient inspired. This resulted in an inspiratory stridor despite adequate glottic opening and normal mobility of the vocal cords. Conclusion: Therefore, in cases where a ball-valve lesion causes intermittent life-threatening airway obstruction, BSCC of the larynx, though rare, must be considered as a differential diagnosis. PMID:26082908

  10. Understanding how brass ball valves passing certification testing can cause elevated lead in water when installed.

    PubMed

    Triantafyllidou, Simoni; Raetz, Meredith; Parks, Jeffrey; Edwards, Marc

    2012-06-15

    The lead leaching potential of new brass plumbing devices has come under scrutiny as a significant source of lead in drinking water (>300 μg/L) of new buildings around the world. Experiments were conducted using ball valves that were sold as certified and known to have caused problems in practice, in order to better understand how installed products could create such problems, even if they passed "leaching tests" such as National Sanitation Foundation (NSF) Standard 61 Section 8. Diffusion of lead from within the device into water when installed can increase lead leaching by orders of magnitude relative to results of NSF testing, which once only required exposure of very small volumes of water within the device. "Normalization" of the lead-in-water result tended to produce estimates of lead concentration that were much lower than actual lead measured at the tap. Finally, the presence of flux could also dramatically increase lead leaching, whereas high water velocity had relatively little effect.

  11. Lubricator valve apparatus

    SciTech Connect

    Brooks, R. T.

    1984-10-16

    A lubricator valve assembly comprises a reciprocably rotatable ball valve which is operated between open and closed positions solely through the selective application of control pressures and/or tubing pressure above the valve to a double acting sleeve type actuating piston. One end of the actuating piston has a valving piston formed thereon which cooperates with a seal bore in the housing to effect the opening or closing of a bypass fluid passage extending from a region below the ball valve to a region above the ball valve. Such valving piston also functions as part of a lost motion connection between the actuating sleeve piston and a reciprocable actuator for rotating the ball valve. In opening the ball valve, the valving piston first moves upwardly to establish a fluid bypass around the closed ball valve and then establishes contact with the actuator to rotate the ball valve to an open position. The same fluid bypass may be utilized to pump through fluid around the closed ball valve by applying fluid pressure above the ball valve. Improved sealing elements for the ball valve are also provided.

  12. The Effect of Pressure Ratio on Unsteady Fluid-Structure Interaction Characteristics of Ball Type Control Valve

    NASA Astrophysics Data System (ADS)

    Du, Yang; Tu, Shan; Wang, Hongjuan

    Two-way sequential fluid-structure interaction method was used to analyze and discuss the characteristics of unsteady fluid-structure interaction of the complex flow channel of a steam turbine ball type control valve. Research indicates that when the pressure ratio changes as a sine wave, its flow rate occurs a sine wave change, and the maximum flow rate value of 57.46kg•s-1 occurs in the minimum pressure ratio condition. The longitudinal force of the structure domain decreases with the reduction of the pressure ratio, and points to the opposite direction of the flow. The lateral force increases with the decrease of the pressure ratio, and points to the opposite direction of the flow. The maximum value of deformation and force of the structure domain changes consistently with the pressure ratio fluctuation. The maximum value of the structure domain stress is 28.67MPa, which is far less than the yield strength of the structure material, and the maximum deformation value is 3.25um.

  13. Quartz ball value

    NASA Technical Reports Server (NTRS)

    Goetz, C.; Ingle, W. M.

    1979-01-01

    Quartz ball valve consisting of two quartz joints sealed back-to-back and seated in quartz sockets perform at temperatures of up to 1,250 C and in corrosive chemical environments without contamination or degradation.

  14. VALVE

    DOEpatents

    Arkelyan, A.M.; Rickard, C.L.

    1962-04-17

    A gate valve for controlling the flow of fluid in separate concentric ducts or channels by means of a single valve is described. In one position, the valve sealing discs engage opposed sets of concentric ducts leading to the concentric pipes defining the flow channels to block flow therethrough. In another position, the discs are withdrawn from engagement with the opposed ducts and at the same time a bridging section is interposed therebetween to define concentric paths coextensive with and connecting the opposed ducts to facilitate flow therebetween. A wedge block arrangement is employed with each sealing disc to enable it to engage the ducts. The wedge block arrangement also facilitates unobstructcd withdrawal of the discs out of the intervening space between the sets of ducts. (AEC)

  15. Valve

    DOEpatents

    Cho, Nakwon

    1980-01-01

    A positive acting valve suitable for operation in a corrosive environment is provided. The valve includes a hollow valve body defining an open-ended bore for receiving two, axially aligned, spaced-apart, cylindrical inserts. One insert, designated the seat insert, terminates inside the valve body in an annular face which lies within plane normal to the axis of the two inserts. An elastomeric O-ring seal is disposed in a groove extending about the annular face. The other insert, designated the wedge insert, terminates inside the valve body in at least two surfaces oppositely inclined with respect to each other and with respect to a plane normal to the axis of the two inserts. An elongated reciprocable gate, movable between the two inserts along a path normal to the axis of the two inserts, has a first flat face portion disposed adjacent and parallel to the annular face of the seat insert. The gate has a second face portion opposite to the first face portion provided with at least two oppositely inclined surfaces for mating with respective inclined surfaces of the wedge insert. An opening is provided through the gate which registers with a flow passage through the two inserts when the valve is open. Interaction of the respective inclined surfaces of the gate and wedge insert act to force the first flat face portion of the gate against the O-ring seal in the seat insert at the limits of gate displacement where it reaches its respective fully open and fully closed positions.

  16. Well safety valve

    SciTech Connect

    Vinzant, M.B.; Hilts, R.L.; Meaders, M.; Speegle, S.C.

    1984-07-24

    A retrievable well safety valve in a cased well system including a tubing string, a dual packer downhole around the tubing sealing with the casing and submersible pump in the tubing string below the packer. The safety valve controls flow of pumped fluids through the tubing to surface and directs gas flow into the casing annulus above the packer. When the safety valve is landed in cooperating tubing nipples above the packer, separated central annular flow passages are formed for pumped fluids and gas respectively. A ball valve in the central flow passage controls pumped fluid flow therethrough and an annular valve coupled to the ball valve controls gas flow from below the packer through the annular flow passage around and by the ball valve. When the ball valve is in the down and open position, the valve ball member engages a lower seat, which maintains the central and annular flow passages separate and prevents comingling flow of fluids and gas. The coupled valves are held open by pressured fluid from surface and are closed automatically on loss of pressure in their control fluid circuits. When the valves close, a circuit of flow passages for recirculating pumped fluids and gas are opened below the ball valve and the pump may continue operation without overload.

  17. Echocardiographic assessment of left ventricular filling after mitral valve surgery.

    PubMed Central

    St John Sutton, M G; Traill, T A; Ghafour, A S; Brown, D J; Gibson, D G

    1977-01-01

    In order to investigate the functional effects of mitral valve surgery, echocardiograms showing left ventricular dimension were recorded and digitised in 14 normal subjects and 129 patients after mitral valve surgery. Measurements were made of peak rate of increase of dimension (dD/dt) and duration of rapid filling, studies on left ventriculograms in 36 patients having shown close correlation between these values and changes in cavity volume. In 14 patients with mitral stenosis, peak dD/dt was reduced to 7-2 +/ 1-5 cm/s, and filling period prolonged to 330 +/- 65 ms, compared with normal (16-0 +/- 3-2 cm/s, and 160 +/- 50 ms, respectively), and after mitral valvotomy, these values improved significantly (10-4 +/- 2-7 cm/s and 245 +/- 55 ms). Characteristic abnormalities were found in 67 patients with mitral prostheses. Values for the Björk-Shiley (10-5 +/- 4-2 cm/s and 180 +/- 80 ms) and Hancock (10-3 +/- 3-7 cm/s, 245 +/- 80 ms) values were similar, and both superior to the Starr-Edwards (7-4 +/- 3-0 cm/s, 295 +/- 105 ms). Results after mitral valve repair in 30 cases were not significantly different from normal (14-4 +/- 5-0 cm/s, 170 +/- 50 ms). Values outside the 95 per cent confidence limits for the valve in question allowed diagnosis of value malfunction in 18 cases. The method is value in comparing different operative procedures and in following up patients after mitral valve surgery. PMID:603728

  18. Colour atlas of first pass functional imaging of the heart

    SciTech Connect

    Schad, N.; Andrews, E.J.; Fleming, J.W.

    1985-01-01

    This book contains 21 chapters. Some of the titles are: Functional imaging; Fist pass radionuclide studies in evaluation of mitral valve replacement in chronic insufficiency using Bjork-Shiley tilting disc valves; First pass radionuclide studies in evaluation of left and right ventricular function in patients with bioprosthetic mitral valve replacement after 9-11 years; and First pass radionuclide studies in the evaluation of long term (up to about 15 years) follow up of aortic valve replacement using Starr-Edwards ball prosthesis.

  19. Unsteady fluid dynamics of several mechanical prosthetic heart valves using a two component laser Doppler anemometer system.

    PubMed

    Akutsu, T; Modi, V J

    1997-10-01

    Five typical mechanical heart valves (Starr-Edwards, Björk-Shiley convexo-concave (c-c), Björk-Shiley monostrut, Bicer-Val, and St. Jude Medical) were tested in the mitral position under the pulsatile flow condition. The test program included measurements of velocity and turbulent stresses at 5 downstream locations. The study was carried out using a sophisticated cardiac simulator in conjunction with a highly sensitive 2 component laser Doppler anemometer (LDA) system. The continuous monitoring of parametric time histories revealed useful details about the complex flow and helped to establish the locations and times of the peak parameter values. Based upon the nondimensional presentation of data, the following general conclusions can be made. First, all the 5 valve designs created elevated turbulent stresses during the accelerating and peak flow phases, presenting the possibility of thromboembolism and perhaps hemolysis. Second, the difference in valve configuration seemed to affect the flow characteristics; third, the bileaflet design of the St. Jude valve appeared to create a lower turbulence stress level.

  20. Whitey Gauge and Root Valves (VPS)

    SciTech Connect

    MISKA, C.

    2000-09-03

    These valves are 1/2 inch ball valves fabricated of 316 stainless steel: Packing is TFE (standard). They are used as isolation valves for pressure instrumentation in the Vacuum Pumping and Helium System.

  1. ULTRA HIGH VACUUM VALVE

    DOEpatents

    Fry, W.A.

    1962-05-29

    A valve for high vacuum applications such as the CStellarator where chamber pressures as low as 2 x 10/sup -10/ mm Hg are necessary is designed with a line-of-sight path through the valve for visual inspection of the contents of reactants in such chambers. The valve comprises a turnable resilient metal ball having an aperture therethrough, means for selectively turning the ball to rotate the axis of its line-of-sight path, and soft, deformable opposing orifices that are movable relatively toward said ball to seal with opposite ball surfaces upon said movement of said axis of said line-of-sight path. The valve also includes a bellows seal connected between said orifices and internal actuating means that eliminates the requirement for gasketed turnable valve closing stems. (AEC)

  2. Ball clay

    USGS Publications Warehouse

    Virta, R.L.

    2001-01-01

    Part of the 2000 annual review of the industrial minerals sector. A general overview of the ball clay industry is provided. In 2000, sales of ball clay reached record levels, with sanitary ware and tile applications accounting for the largest sales. Ball clay production, consumption, prices, foreign trade, and industry news are summarized. The outlook for the ball clay industry is also outlined.

  3. Valve for abrasive material

    SciTech Connect

    Gardner, Harold S.

    1982-01-01

    A ball valve assembly for controlling the flow of abrasive particulates including an enlarged section at the bore inlet and an enlarged section at the bore outlet. A refractory ceramic annular deflector is positioned in each of the enlarged sections, substantially extending the useful life of the valve.

  4. Electro-Mechanical Coaxial Valve

    NASA Technical Reports Server (NTRS)

    Patterson, Paul R (Inventor)

    2004-01-01

    Coaxial valves usually contain only one moving part. It has not been easy, then, to provide for electric motor actuation. Many actuators being proposed involve designs which lead to bulky packages. The key facing those improving coaxial valves is the provision of suitable linear actuation. The valve herein indudes a valve housing with a flow channel there-through. Arranged in the flow channel is a closing body. In alignment with the closing body is a ball screw actuator which includes a ball nut and a cylindrical screw. The ball nut sounds a threaded portion of the cylindrical screw. The cylindrical screw is provided with a passageway there-through through which fluid flows. The cylindrical screw is disposed in the flow channel to become a control tube adapted to move toward and away from the valve seat. To rotate the ball nut an actuating drive is employed driven by a stepper motor.

  5. Ball clay

    USGS Publications Warehouse

    Virta, Robert L.

    2010-01-01

    The article reports on the global market performance of ball clay in 2009 and presents an outlook for its 2010 performance. Several companies mined ball call in the country including Old Hickey Clay Co., Kentucky-Tennessee Clay Co., and H.C. Spinks Clay Co. Information on the decline in ball clay imports and exports is also presented.

  6. 241-AN-B valve pit manifold valves and position indication acceptance test procedure

    SciTech Connect

    VANDYKE, D.W.

    1999-08-25

    This document describes the method used to test design criteria for gear actuated ball valves installed in 241-AN-B Valve Pit located at 200E Tank Farms. The purpose of this procedure is to demonstrate the following: Equipment is properly installed, labeled, and documented on As-Built drawings; New Manifold Valves in the 241-AN-B Valve Pit are fully operable using the handwheel of the valve operators; New valve position indicators on the valve operators will show correct valve positions; New valve position switches will function properly; and New valve locking devices function properly.

  7. 241-AN-A valve pit manifold valves and position indication acceptance test procedure

    SciTech Connect

    VANDYKE, D.W.

    1999-08-25

    This document describes the method used to test design criteria for gear actuated ball valves installed in 241-AN-A Valve Pit located at 200E Tank Farms. The purpose of this procedure is to demonstrate the following: Equipment is properly installed, labeled, and documented on As-Built drawings; New Manifold Valves in the 241-AN-A Valve Pit are fully operable using the handwheel of the valve operators; New valve position indicators on the valve operators will show correct valve positions; New valve position switches will function properly; and New valve locking devices function properly.

  8. Evaluation of Cylinder, Solenoid Valve and Servovalve Contaminant Sensitivity

    DTIC Science & Technology

    1984-02-01

    observed on poppets in relief valves and balls A in check valves as well as servovalve spool orifices. In Ref. [9], it was stated that performance...in these fields of applications. In fluid power systems, particle impingement erosion can be observed on poppets in relief valves and balls in check... poppet system inside, normally, spool-housing type valves do not have critical failure or degradation due to qD wear. With spool-housing type valves , wear

  9. Ball clay

    USGS Publications Warehouse

    Virta, R.L.

    2011-01-01

    The article discusses the latest developments in the global ball clay mining industry, particularly in the U.S., as of June 2011. It cites several firms that are involved in ball clay mining in the U.S., including HC Spins Clay Co. Inc., the Imerys Group and Old Hickory Clay Co. Among the products made from ball clay are ceramic tiles, sanitaryware, as well as fillers, extenders and binders.

  10. Ball clay

    USGS Publications Warehouse

    Virta, R.L.

    2006-01-01

    In 2005, four companies including H.C. Spinks Clay, Kentucky-Tennessee Clay, Old Hickory Clay and Unimin mined ball clay in four states. Based on a preliminary survey of the ball clay industry, production reached 1.32 Mt valued at $53.3 million. Tennessee was the leading ball clay producer state with 61% of domestic production, followed by Texas, Mississippi and Kentucky.

  11. Ball clay

    USGS Publications Warehouse

    Virta, R.L.

    2000-01-01

    Part of the 1999 Industrial Minerals Review. The state of the ball clay industry in 1999 is presented. Record highs in the sales and use of ball clay were attained in 1999 due to the continued strength of the U.S. economy. U.S. production was estimated at 1.25 million st for the year, with more than half of that amount mined in Tennessee. Details of the consumption, price, imports, and exports of ball clay in 1999 and the outlook for ball clay over the next few years are provided.

  12. Energy conservation with automatic flow control valves

    SciTech Connect

    Phillips, D.

    1984-12-01

    Automatic flow control valves are offered in a wide range of sizes starting at 1/2 in. with flow rates of 0.5 gpm and up. They are also provided with materials and end connections to meet virtually any fan-coil system requirement. Among these are copper sweat type valves; ductile iron threaded valves; male/female threaded brass valves; and combination flow control/ball valves with union ends.

  13. Ball clay

    USGS Publications Warehouse

    Virta, R.L.

    2013-01-01

    Four companies — H.C. Spinks Clay Co., Inc., Imerys, Old Hickory Clay Co. and Unimin Corp. — mined ball clay in five U.S. states in 2012. Production, on the basis of preliminary data, was 900 kt (992,000 st), with an estimated value of $42.3 million. This was a slight increase in tonnage from 886 kt (977,000 st), with a value of $40.9 million in 2011. Tennessee was the leading ball clay producing state, with 63 percent of domestic production, followed by Texas, Mississippi, Kentucky and Indiana. Reported ball clay production from Indiana probably was fire clay rather than ball clay. About 69 percent of total ball clay production was airfloat, 20 percent was crude and 11 percent was water-slurried.

  14. Fast closing valve

    DOEpatents

    Hanson, Clark L.

    1984-01-10

    A valve is provided for protecting the high vacuum of a particle accelera in the event of air leakage, wherein the valve provides an axially symmetrical passage to avoid disturbance of the partical beam during normal operation, and yet enables very rapid and tight closure of the beam-carrying pipe in the event of air leakage. The valve includes a ball member (30) which can rotate between a first position wherein a bore (32) in the member is aligned with the beam pipe, and a second position out of line with the pipe. A seal member (38) is flexibly sealed to the pipe, and has a seal end which can move tightly against the ball member after the bore has rotated out of line with the pipe, to thereby assure that the seal member does not retard rapid rotation of the ball valve member. The ball valve member can be rapidly rotated by a conductive arm (40) fixed to it and which is rotated by the discharge of a capacitor bank through coils (44, 45) located adjacent to the arm.

  15. Fast closing valve

    SciTech Connect

    Hanson, C.L.

    1984-01-10

    A valve is provided for protecting the high vacuum of a particle accelerator in the event of air leakage, wherein the valve provides an axially symmetrical passage to avoid disturbance of the partical beam during normal operation, and yet enables very rapid and tight closure of the beam-carrying pipe in the event of air leakage. The valve includes a ball member which can rotate between a first position wherein a bore in the member is aligned with the beam pipe, and a second position out of line with the pipe. A seal member is flexibly sealed to the pipe, and has a seal end which can move tightly against the ball member after the bore has rotated out of line with the pipe, to thereby assure that the seal member does not retard rapid rotation of the ball valve member. The ball valve member can be rapidly rotated by a conductive arm fixed to it and which is rotated by the discharge of a capacitor bank through coils located adjacent to the arm.

  16. Ball lightning

    NASA Astrophysics Data System (ADS)

    Stenhoff, Mark

    Ball lightning is alleged by some to be a rare atmospheric phenomenon usually associated with thunderstorms, while others hold that it does not exist. This controversy has continued for centuries. This study comprises a critical evaluation of evidence for the existence of ball lightning. An historical review of the controversy is first presented, giving a chronological account of developments in ball lightning theories and of important observations alleged to be of the phenomenon. Other phenomena which might be mistaken for ball lightning are then subjected to a more detailed study than has hitherto been published, and the means by which such misidentifications could be recognized areestablished. A discussion of psychological and perceptual aspects indicates that descriptions could not always be taken at face value, and that many accounts of alleged ball lightning would be expected to contain substantial inaccuracies. The original intention to evaluate cases of alleged ball lightning already published in scientific journals was abandoned because there was no standardisation of information content, and because the majority of reports contained insufficient information for evaluation. Many reports had been written in a style which indicated an assumption that ball lightning was the cause of the event. Approximately 200 unpublished reports were therefore collected and subjected to evaluation. It was found that the majority of reports of alleged ball lightning could be explained by other means, and there was only a very small residue of reports which could not easily be thus explained. A large proportion of the reports could be attributed to corona discharge effects such as St Elmo's fire, or by familiar effects of conventional linear lightning. The validity of many previously published statistical studies of ball lightning was shown to be doubtful. The thesis concludes with a comparitive discussion of the merits and demerits of some of the diverse physical models

  17. Liquid blocking check valve

    DOEpatents

    Merrill, John T.

    1984-01-01

    A liquid blocking check valve useful particularly in a pneumatic system utilizing a pressurized liquid fill chamber. The valve includes a floatable ball disposed within a housing defining a chamber. The housing is provided with an inlet aperture disposed in the top of said chamber, and an outlet aperture disposed in the bottom of said chamber in an offset relation to said inlet aperture and in communication with a cutaway side wall section of said housing.

  18. Valve-"Health"-Monitoring System

    NASA Technical Reports Server (NTRS)

    Jensen, Scott L.; Drouant, George J.

    2009-01-01

    A system that includes sensors and data acquisition, wireless data-communication, and data-processing subsystems has been developed as a means of both real-time and historical tracking of information indicative of deterioration in the mechanical integrity and performance of a highgeared ball valve or a linearly actuated valve that operates at a temperature between cryogenic and ambient.

  19. Valve designed with elastic seat

    NASA Technical Reports Server (NTRS)

    Mac Glashan, W. F., Jr.

    1965-01-01

    Absolute valve closure is accomplished by a machined valve with an axially annular channel which changes the outlet passage into a thin tubular elastic seat member with a retainer backup ring. The elasticity of the seat provides tight conformity to ball irregularity.

  20. Whitey SCHE Gauge and Root Valves

    SciTech Connect

    VAN KATWIJK, C.

    2000-06-21

    These valves are 1/2 inch ball valves fabricated of 316 stainless steel. Packing is TFE (standard). They are used as isolation valves for pressure instrumentation in the SCHe System between the helium bottle supply manifolds and safety class helium pressure instrumentation, and in lower pressure SCHe supply line.

  1. Whitey SCHE Gauge and Root Valves

    SciTech Connect

    MISKA, C.R.

    2000-09-03

    These valves are 1/2 inch ball valves fabricated of 316 stainless steel. Packing is TFE (standard). They are used as isolation valves for pressure instrumentation in the SCHe System between the helium bottle supply manifolds and safety class helium pressure instrumentation, and in lower pressure SCHe supply line.

  2. Whitey SCHE Gauge and Root Valves

    SciTech Connect

    MISKA, C.R.

    2000-09-11

    These valves are 1/2 inch ball valves fabricated of 316 stainless steel. Packing is TFE (standard). They are used as isolation valves for pressure instrumentation in the SCHa System between the helium bottle supply manifolds and safety class helium pressure instrumentation, and in lower pressure SCHa supply line.

  3. Golf Ball

    NASA Technical Reports Server (NTRS)

    1998-01-01

    The Ultra 500 Series golf balls, introduced in 1995 by Wilson Sporting Goods Company, has 500 dimples arranged in a pattern of 60 spherical triangles. The design employs NASA's aerodynamics technology analysis of air loads of the tank and Shuttle orbiter that was performed under the Space Shuttle External Tank program. According to Wilson, this technology provides 'the most symmetrical ball surface available, sustaining initial velocity longer and producing the most stable ball flight for unmatched accuracy and distance.' The dimples are in three sizes, shapes and depths mathematically positioned for the best effect. The selection of dimples and their placement optimizes the interaction of opposing forces of lift and drag. Large dimples reduce air drag, enhance lift, and maintain spin for distance. Small dimples prevent excessive lift that destabilizes the ball flight and the medium size dimples blend the other two.

  4. Ball clay

    USGS Publications Warehouse

    Virta, R.L.

    2007-01-01

    The article offers information on ball clay. Among the companies that mine ball clay in the U.S. are H.C. Spinks Clay, Kentucky-Tennessee Clay and Old Hickory Clay. In 2006, an estimated 1.2 million tons of the mineral was sold or used domestically and exported. Forty-percent of the total sales is accounted for ceramic floor and wall tile followed by sanitaryware and miscellaneous ceramics. Its average value was $ 45 per ton in 2006.

  5. Conical Seat Shut-Off Valve

    NASA Technical Reports Server (NTRS)

    Farner, Bruce

    2013-01-01

    A moveable valve for controlling flow of a pressurized working fluid was designed. This valve consists of a hollow, moveable floating piston pressed against a stationary solid seat, and can use the working fluid to seal the valve. This open/closed, novel valve is able to use metal-to-metal seats, without requiring seat sliding action; therefore there are no associated damaging effects. During use, existing standard high-pressure ball valve seats tend to become damaged during rotation of the ball. Additionally, forces acting on the ball and stem create large amounts of friction. The combination of these effects can lead to system failure. In an attempt to reduce damaging effects and seat failures, soft seats in the ball valve have been eliminated; however, the sliding action of the ball across the highly loaded seat still tends to scratch the seat, causing failure. Also, in order to operate, ball valves require the use of large actuators. Positioning the metal-to-metal seats requires more loading, which tends to increase the size of the required actuator, and can also lead to other failures in other areas such as the stem and bearing mechanisms, thus increasing cost and maintenance. This novel non-sliding seat surface valve allows metal-to-metal seats without the damaging effects that can lead to failure, and enables large seating forces without damaging the valve. Additionally, this valve design, even when used with large, high-pressure applications, does not require large conventional valve actuators and the valve stem itself is eliminated. Actuation is achieved with the use of a small, simple solenoid valve. This design also eliminates the need for many seals used with existing ball valve and globe valve designs, which commonly cause failure, too. This, coupled with the elimination of the valve stem and conventional valve actuator, improves valve reliability and seat life. Other mechanical liftoff seats have been designed; however, they have only resulted in

  6. Ball feeder for replenishing evaporator feed

    DOEpatents

    Felde, David K.; McKoon, Robert H.

    1993-01-01

    Vapor source material such as uranium, which is to be dropped into a melt in an evaporator, is made into many balls of identical diameters and placed inside a container. An elongated sloping pipe is connected to the container and leads to the evaporator such that these balls can travel sequentially therealong by gravity. A metering valve in this pipe for passing these balls one at a time is opened in response to a signal when it is ascertained by a detector that there is a ball ready to be passed. A gate in the pipe near the evaporator momentarily stops the motion of the traveling ball and is then opened to allow the ball drop into the melt at a reduced speed.

  7. Ball feeder for replenishing evaporator feed

    DOEpatents

    Felde, D.K.; McKoon, R.H.

    1993-03-23

    Vapor source material such as uranium, which is to be dropped into a melt in an evaporator, is made into many balls of identical diameters and placed inside a container. An elongated sloping pipe is connected to the container and leads to the evaporator such that these balls can travel sequentially therealong by gravity. A metering valve in this pipe for passing these balls one at a time is opened in response to a signal when it is ascertained by a detector that there is a ball ready to be passed. A gate in the pipe near the evaporator momentarily stops the motion of the traveling ball and is then opened to allow the ball drop into the melt at a reduced speed.

  8. Comparison of modified chandler, roller pump, and ball valve circulation models for in vitro testing in high blood flow conditions: application in thrombogenicity testing of different materials for vascular applications.

    PubMed

    van Oeveren, Wim; Tielliu, Ignace F; de Hart, Jurgen

    2012-01-01

    Three different models, a modified Chandler loop, roller pump, and a new ball valve model (Hemobile), were compared with regard to intrinsic damage of blood components and activation of platelets. The Hemobile was used for testing of polymer tubes. High flow was not possible with the Chandler loop. The roller pump and the Hemobile could be adjusted to high flow, but he pump induced hemolysis. Platelet numbers were reduced in the roller pump and Chandler loop (P < 0.05), but remained high in the Hemobile. Platelet aggregation was reduced in all models. The Hemobile was applied for testing vascular graft materials, and allowed different circuits circulated simultaneously at 37°C. ePTFE, Dyneema Purity UHMWPE fiber and PET fiber based tubes, all showed hemolysis below 0.2% and reduced platelet count and function. Binding of fibrin and platelets was higer on PET, inflammatory markers were lowest on Dyneema Purity UHMWPE. We concluded that the Hemobile minimally affects blood and could be adjusted to high blood flows, simulating arterial shear stress. The Hemobile was used to measure hemocompatibility of graft material and showed Dyneema Purity UHMWPE fiber in many ways more hemocompatible than ePTFE and PET.

  9. CFD analysis of a ball check microvalve

    NASA Astrophysics Data System (ADS)

    Cǎlimǎnescu, Ioan; Dumitrache, Constantin L.; Grigorescu, Lucian

    2015-02-01

    The microvalves with balls as seen before are used in many applications and their behaviour in terms of fluid dynamics mainly at their opening time (when as demonstrated the ball is bouncing up and down altering the flow parameters) is of a paramount importance. The present study is focused on a micro check ball valve circulating a fluid air-like (with the same constant proprieties). The CFD model is taking into account a transitory zone of functioning from zero time when the pressure inside a "tank" is reaching the opening pressure of the valve, to the final step 0.05 seconds when the ball is stabilizing after bouncing up and down. The geometry of the valve with dimensions in μm is given below (the model is comprising a "slice" of 5 μm thickness extracted from the entire valve. In this paper by using advanced numeric techniques, the behavior of the valve in its transitory opening stage was studied with credible and useful results for further optimisation studies.

  10. Electromechanically Actuated Valve for Controlling Flow Rate

    NASA Technical Reports Server (NTRS)

    Patterson, Paul

    2007-01-01

    A proposed valve for controlling the rate of flow of a fluid would include an electric-motor-driven ball-screw mechanism for adjusting the seating element of the valve to any position between fully closed and fully open. The motor would be of a type that can be electronically controlled to rotate to a specified angular position and to rotate at a specified rate, and the ball screw would enable accurate linear positioning of the seating element as a function of angular position of the motor. Hence, the proposed valve would enable fine electronic control of the rate of flow and the rate of change of flow. The uniqueness of this valve lies in a high degree of integration of the actuation mechanism with the flow-control components into a single, relatively compact unit. A notable feature of this integration is that in addition to being a major part of the actuation mechanism, the ball screw would also be a flow-control component: the ball screw would be hollow so as to contain part of the main flow passage, and one end of the ball screw would be the main seating valve element. The relationships among the components of the valve are best understood by reference to the figure, which presents meridional cross sections of the valve in the fully closed and fully open positions. The motor would be supported by a bracket bolted to the valve body. By means of gears or pulleys and a timing belt, motor drive would be transmitted to a sleeve that would rotate on bearings in the valve body. A ball nut inside the sleeve would be made to rotate with the sleeve by use of a key. The ball screw would pass through and engage the ball nut. A key would prevent rotation of the ball screw in the valve body while allowing the ball screw to translate axially when driven by the ball nut. The outer surface of the ball screw would be threaded only in a mid-length region: the end regions of the outer surface of the ball screw would be polished so that they could act as dynamic sealing surfaces

  11. Spring-Loaded Joule-Thomson Valve

    NASA Technical Reports Server (NTRS)

    Jones, J. A.; Britcliffe, M. J.

    1986-01-01

    Improved design reduces clogging and maintains constant pressure drop as flow rate varies. Spring-Loaded Joule-Thomson Valve pressure drop regulated by spring pushing stainless-steel ball against soft brass seat. Pressure drop remains nearly constant, regardless of helium flow rate and of any gas contaminants frozen on valve seat. Because springloaded J-T valve maintains constant pressure drop, upstream roomtemperature throttle valve adjusts flow rate precisely for any given upstream pressure. In addition, new valve relatively invulnerable to frozen gas contaminants, which clog fixed-orifice J-T valves.

  12. Science of Ball Lightning (Fire Ball)

    NASA Astrophysics Data System (ADS)

    Ohtsuki, Yoshi-Hiko

    1989-08-01

    The Table of Contents for the full book PDF is as follows: * Organizing Committee * Preface * Ball Lightning -- The Continuing Challenge * Hungarian Ball Lightning Observations in 1987 * Nature of Ball Lightning in Japan * Phenomenological and Psychological Analysis of 150 Austrian Ball Lightning Reports * Physical Problems and Physical Properties of Ball Lightning * Statistical Analysis of the Ball Lightning Properties * A Fluid-Dynamical Model for Ball Lightning and Bead Lightning * The Lifetime of Hill's Vortex * Electrical and Radiative Properties of Ball Lightning * The Candle Flame as a Model of Ball Lightning * A Model for Ball Lightning * The High-Temperature Physico-Chemical Processes in the Lightning Storm Atmosphere (A Physico-Chemical Model of Ball Lightning) * New Approach to Ball Lightning * A Calculation of Electric Field of Ball Lightning * The Physical Explanation to the UFO over Xinjiang, Northern West China * Electric Reconnection, Critical Ionization Velocity, Ponderomotive Force, and Their Applications to Triggered and Ball Lightning * The PLASMAK™ Configuration and Ball Lightning * Experimental Research on Ball Lightning * Performance of High-Voltage Test Facility Designed for Investigation of Ball Lightning * List of Participants

  13. Well safety and kill valve

    SciTech Connect

    Deaton, T.M.

    1986-12-30

    A valve device is described for use in tubing above a packer set in casing above a well formation comprising: (a) a housing connectable in well tubing and having a longitudinal flow passage therethrough and a flow passage through the housing wall intersecting the longitudinal flow passage; (b) lower ball valve means controlling flow through the longitudinal flow passage; (c) upper sleeve valve means controlling flow through the housing wall flow passages between the valve device exterior and the longitudinal flow passage. The valve means is cooperable such that when the upper valve means is in closed position, the lower valve means is in open position, and when the upper valve means is in open position, the lower valve means is in closed position; (d) locking means for holding the valve means at one position and releasing the valve means for movement to another position; (e) pressure responsive means for releasing the locking means; and (f) operator means for operating the valve means between positions including an operator tube having a shoulder thereon, mounted for longitudinal movement in the housing, an internal shoulder in the housing and a spring disposed around the operator tube between the housing and operator tube shoulders, biasing the operator tube upwardly.

  14. Safety valve

    DOEpatents

    Bergman, Ulf C.

    1984-01-01

    The safety valve contains a resilient gland to be held between a valve seat and a valve member and is secured to the valve member by a sleeve surrounding the end of the valve member adjacent to the valve seat. The sleeve is movable relative to the valve member through a limited axial distance and a gap exists between said valve member and said sleeve.

  15. Low pressure piezoelectric valve design

    NASA Astrophysics Data System (ADS)

    Bernard, Y.; Razek, A.

    2012-06-01

    In this paper a ball-type valve actuated by a piezoelectric bender is studied. In this valve different parameters are adjustable allowing different operational aspects. The design procedure is economic and easy to test. Some models are developed to allow an optimization of the structure for special requirements. A prototype has been manufactured to verify the models. The measurement procedure is exposed. This design does not allow high tank pressure but, on this basis, a structure where the pressure locks the ball (reverse structure) is possible.

  16. Liquid-blocking check valve

    DOEpatents

    Merrill, J.T.

    1982-09-27

    A liquid blocking check valve useful particularly in a pneumatic system utilizing a pressurized liquid fill chamber. The valve includes a floatable ball disposed within a housing defining a chamber. The housing is provided with an inlet aperture disposed in the top of said chamber, and an outlet aperture disposed in the bottom of said chamber in an offset relation to said inlet aperture and in communication with a cutaway side wall section of said housing.

  17. Four ball best ball 1.

    PubMed

    Pollard, Geoff; Pollard, Graham

    2010-01-01

    In this paper a four-ball-best-ball (4BBB) model for pairs of golf players is set up. The 4BBB match-play scoring system is seen to satisfy a basic requirement of fairness. It is shown that it is not strictly possible to rate individual players as 4BBB players. However, a (reasonably broad) class of individual players is identified such that it is possible to rate them individually as 4BBB players. The capacity of an individual to play birdies is seen to be a very important determinant in being a successful member of a 4BBB pair, but there are other minor factors as well. Consideration is given to equal and unequal 4BBB pairs. The transitive law is seen to apply for 4BBB pairs. Thus, if pair A is better than pair B, and pair B is better than pair C, then pair A must be better than pair C. Correspondingly, if pair A is equal to pair B, and pair B is equal to pair C, then pair A is equal to pair C. Consideration is given to some strategic issues in 4BBB match-play golf. For example, the conditions under which a player should take a greater risk and have a higher probability of obtaining a bogie in order to achieve a higher probability of scoring a birdie, are determined. Also, the conditions under which a player, noting that his partner is about to have a 'bad' hole and score only a par or a bogie, should 'play safe', are determined. Thirdly, players who can interact in certain ways are seen to have an advantage over those pairs that cannot do this. Finally, one pair's optimal strategy when they see that their opponents are about to score a par or a bogie, but not a birdie, is analyzed. Key pointsA model for four-ball-best-ball match-play golf is established, and used to show that, although there can be other factors, the capacity of an individual to play birdies is a very important determinant in that player being a successful member of a four-ball-best-ball pair.Although it is not possible in general to rate play-ers individually as 4BBB players, a class of indi

  18. Ban Deodorant Ball Mortar.

    ERIC Educational Resources Information Center

    Carpenter, D. Rae, Jr.; And Others

    1988-01-01

    Discusses a demonstration of vertical collision of two balls. Shows the theoretical height ratio using mathematical expression and diagrams. Compares it with researchers' experimental results. Expands the two-ball collision to multi-ball system. (YP)

  19. 40 CFR 63.175 - Quality improvement program for valves.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (e.g., ball, gate, check); valve manufacturer; valve design (e.g., external stem or actuating... improvement program. (6) A trial evaluation program shall be conducted at each plant site for which the data... required in § 63.181(h)(5)(ii) of this subpart. (ii) The number of valves in the trial evaluation...

  20. 40 CFR 63.175 - Quality improvement program for valves.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (e.g., ball, gate, check); valve manufacturer; valve design (e.g., external stem or actuating... improvement program. (6) A trial evaluation program shall be conducted at each plant site for which the data... required in § 63.181(h)(5)(ii) of this subpart. (ii) The number of valves in the trial evaluation...

  1. 40 CFR 63.175 - Quality improvement program for valves.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (e.g., ball, gate, check); valve manufacturer; valve design (e.g., external stem or actuating... improvement program. (6) A trial evaluation program shall be conducted at each plant site for which the data... required in § 63.181(h)(5)(ii) of this subpart. (ii) The number of valves in the trial evaluation...

  2. Improve pumping efficiency with PSZ ceramic balls

    SciTech Connect

    Brothers, J. )

    1989-04-01

    partially stabilized zirconia (PSZ) ceramic balls used today in downhole pumps improve both the efficiency and run time of sucker rod pumping systems. Recent field tests showed the balls increased the average run time of downhole pumps by 440%. While there are other types of stabilizers, only magnesia PSZ is appropriate for downhole pumps. The more commonly found alloy balls and carbide balls have been found to deform and not seal under these conditions. PSZ is most notable for its resistance to breaking from impact. A nonductile material, it will make a perfect seal on the seat despite any impact, enhancing its use in fluid pound situations. Other PSZ applications in downhole pumps and related equipment include plunger inserts, discharge inserts, plunger rings, choke parts, pressure relief valve components, and triplex pump plungers.

  3. Ball clay

    USGS Publications Warehouse

    Virta, R.L.

    2012-01-01

    Four companies — H.C. Spinks Clay Co., Inc., Imerys Group, Old Hickory Clay Co., and Unimin Corp. — mined ball clay in four states in 2011. Production, on the basis of preliminary data, was 940 kt (1.04 million st) with an estimated value of $44.2 million. This is a 3-percent increase in tonnage from 912 kt (1.01 million st) with a value of $41.3 million that was produced in 2010. Tennessee was the leading producing state with 63 percent of domestic production, followed by Texas, Mississippi and Kentucky. About 69 percent of production was airfloat, 20 percent was crude and 11 percent was water-slurried.

  4. Combined pressure regulator and shutoff valve

    NASA Technical Reports Server (NTRS)

    Koch, E. F. (Inventor)

    1974-01-01

    A remotely operable pressure regulator and shutoff valve particularly suited for achieving high resolution and flow control, and positive shutoff is described. The valve is characterized by a spring-loaded ball coaxially aligned with a fluid port to be sealed, a spring-loaded pintle extended through the port into engagement with the ball, for controlling the position, a spring-loaded diaphragm for controlling the position of the pintle, and an axially displaceable spring supported by a movable stop which, in turn, is repositioned by a selectively operable stepper motor. Thus, the pressure-response characteristics for the valve can be varied through a selective repositioning of the stop.

  5. Bouncing Balls that Spin

    ERIC Educational Resources Information Center

    Knipp, Peter

    2008-01-01

    When a ball bounces elastically against a floor, the vertical component (v[subscript y]) of the velocity of the ball's mass-center changes sign. This is a special case of the elastic collision of two balls (i.e., two objects, neither of which is much more massive than the other), in which case the balls' post-collision relative velocity (=…

  6. Bouncing Balls that Spin

    ERIC Educational Resources Information Center

    Knipp, Peter

    2008-01-01

    When a ball bounces elastically against a floor, the vertical component (v[subscript y]) of the velocity of the ball's mass-center changes sign. This is a special case of the elastic collision of two balls (i.e., two objects, neither of which is much more massive than the other), in which case the balls' post-collision relative velocity (=…

  7. Fluid mechanics of heart valves.

    PubMed

    Yoganathan, Ajit P; He, Zhaoming; Casey Jones, S

    2004-01-01

    Valvular heart disease is a life-threatening disease that afflicts millions of people worldwide and leads to approximately 250,000 valve repairs and/or replacements each year. Malfunction of a native valve impairs its efficient fluid mechanic/hemodynamic performance. Artificial heart valves have been used since 1960 to replace diseased native valves and have saved millions of lives. Unfortunately, despite four decades of use, these devices are less than ideal and lead to many complications. Many of these complications/problems are directly related to the fluid mechanics associated with the various mechanical and bioprosthetic valve designs. This review focuses on the state-of-the-art experimental and computational fluid mechanics of native and prosthetic heart valves in current clinical use. The fluid dynamic performance characteristics of caged-ball, tilting-disc, bileaflet mechanical valves and porcine and pericardial stented and nonstented bioprostheic valves are reviewed. Other issues related to heart valve performance, such as biomaterials, solid mechanics, tissue mechanics, and durability, are not addressed in this review.

  8. Plug valve

    DOEpatents

    Wordin, John J.

    1989-01-01

    An improved plug valve wherein a novel shape for the valve plug and valve chamber provide mating surfaces for improved wear characteristics. The novel shape of the valve plug is a frustum of a body of revolution of a curved known as a tractrix, a solid shape otherwise known as a peudosphere.

  9. Heated-Pressure-Ball Monopropellant Rocket Engine

    NASA Technical Reports Server (NTRS)

    Greene, William D.

    2005-01-01

    A recent technology disclosure presents a concept for a monopropellant thermal spacecraft thruster that would feature both the simplicity of a typical prior pressure-fed propellant supply system and the smaller mass and relative compactness of a typical prior pump-fed system. The source of heat for this thruster would likely be a nuclear- fission reactor. The propellant would be a cryogenic fluid (a liquefied low-molecular-weight gas) stored in a tank at a low pressure. The propellant would flow from the tank, through a feedline, into three thick-walled spherical tanks, denoted pressure balls, that would be thermally connected to the reactor. Valves upstream and downstream of the pressure balls would be operated in a three-phase cycle in which propellant would flow into one pressure ball while the fluid underwent pressurization through heating in another ball and pressurized propellant was discharged from the remaining ball into the reactor. After flowing through the reactor, wherein it would be further heated, the propellant would be discharged through an exhaust nozzle to generate thrust. A fraction of the pressurized gas from the pressure balls would be diverted to maintain the desired pressure in the tank.

  10. Current Status of Prosthetic Cardiac Valves

    PubMed Central

    Huse, Wilfred M.; Wareham, Ellsworth E.

    1967-01-01

    The majority of patients with acquired valvular heart disease have severe damage to valves which is not amenable to repair but can now be treated by valve replacement with an acceptable mortality and morbidity. The caged ball or disc valve is widely used and is proving clinically satisfactory for cardiac valve replacement. Thromboembolism is the significant complication. With improvement in technique the incidence of infection, detachment and other complications has been reduced. ImagesFigure 1.Figure 2.Figure 4.Figure 5.Figure 6.Figure 7.Figure 8.Figure 9.Figure 10. PMID:6039188

  11. Having a Ball with Fitness Balls

    ERIC Educational Resources Information Center

    McNulty, Betty

    2011-01-01

    Fitness programs can be greatly enhanced with the addition of fitness balls. They are a fun, challenging, economical, and safe way to incorporate a cardiovascular, strength, and stretching program for all fitness levels in a physical education setting. The use of these balls has become more popular during the last decade, and their benefits and…

  12. Having a Ball with Fitness Balls

    ERIC Educational Resources Information Center

    McNulty, Betty

    2011-01-01

    Fitness programs can be greatly enhanced with the addition of fitness balls. They are a fun, challenging, economical, and safe way to incorporate a cardiovascular, strength, and stretching program for all fitness levels in a physical education setting. The use of these balls has become more popular during the last decade, and their benefits and…

  13. The Goldenrod Ball Gall

    ERIC Educational Resources Information Center

    Fischer, Richard B.

    1974-01-01

    The paper presents a generalized life history of the goldenrod ball gall, a ball-shaped swelling found almost exclusively on the Canada goldenrod, Solidago canadensis, and caused by a peacock fly know as Eurosta soldiaginis. (KM)

  14. FLUID MECHANICS OF ARTIFICIAL HEART VALVES

    PubMed Central

    Dasi, Lakshmi P; Simon, Helene A; Sucosky, Philippe; Yoganathan, Ajit P

    2009-01-01

    SUMMARY 1. Artificial heart valves have been in use for over five decades to replace diseased heart valves. Since the first heart valve replacement performed with a caged-ball valve, more than 50 valve designs have been developed, differing principally in valve geometry, number of leaflets and material. To date, all artificial heart valves are plagued with complications associated with haemolysis, coagulation for mechanical heart valves and leaflet tearing for tissue-based valve prosthesis. For mechanical heart valves, these complications are believed to be associated with non-physiological blood flow patterns. 2. In the present review, we provide a bird’s-eye view of fluid mechanics for the major artificial heart valve types and highlight how the engineering approach has shaped this rapidly diversifying area of research. 3. Mechanical heart valve designs have evolved significantly, with the most recent designs providing relatively superior haemodynamics with very low aerodynamic resistance. However, high shearing of blood cells and platelets still pose significant design challenges and patients must undergo life-long anticoagulation therapy. Bioprosthetic or tissue valves do not require anticoagulants due to their distinct similarity to the native valve geometry and haemodynamics, but many of these valves fail structurally within the first 10–15 years of implantation. 4. These shortcomings have directed present and future research in three main directions in attempts to design superior artificial valves: (i) engineering living tissue heart valves; (ii) development of advanced computational tools; and (iii) blood experiments to establish the link between flow and blood damage. PMID:19220329

  15. Check valve

    DOEpatents

    Upton, H.A.; Garcia, P.

    1999-08-24

    A check valve for use in a GDCS of a nuclear reactor and having a motor driven disk including a rotatable armature for rotating the check valve disk over its entire range of motion is described. In one embodiment, the check valve includes a valve body having a coolant flow channel extending therethrough. The coolant flow channel includes an inlet end and an outlet end. A valve body seat is located on an inner surface of the valve body. The check valve further includes a disk assembly, sometimes referred to as the motor driven disc, having a counterweight and a disk shaped valve. The disk valve includes a disk base having a seat for seating with the valve body seat. The disk assembly further includes a first hinge pin member which extends at least partially through the disk assembly and is engaged to the disk. The disk valve is rotatable relative to the first hinge pin member. The check valve also includes a motor having a stator frame with a stator bore therein. An armature is rotatably positioned within the stator bore and the armature is coupled to the disk valve to cause the disk valve to rotate about its full range of motion. 5 figs.

  16. Check valve

    DOEpatents

    Upton, Hubert Allen; Garcia, Pablo

    1999-08-24

    A check valve for use in a GDCS of a nuclear reactor and having a motor driven disk including a rotatable armature for rotating the check valve disk over its entire range of motion is described. In one embodiment, the check valve includes a valve body having a coolant flow channel extending therethrough. The coolant flow channel includes an inlet end and an outlet end. A valve body seat is located on an inner surface of the valve body. The check valve further includes a disk assembly, sometimes referred to as the motor driven disc, having a counterweight and a disk shaped valve. The disk valve includes a disk base having a seat for seating with the valve body seat. The disk assembly further includes a first hinge pin member which extends at least partially through the disk assembly and is engaged to the disk. The disk valve is rotatable relative to the first hinge pin member. The check valve also includes a motor having a stator frame with a stator bore therein. An armature is rotatably positioned within the stator bore and the armature is coupled to the disk valve to cause the disk valve to rotate about its full range of motion.

  17. Fizz-Ball Fizzics

    ERIC Educational Resources Information Center

    Moinester, Murray; Gerland, Lars; Liger-Belair, Gerard; Ocherashvili, Aharon

    2012-01-01

    We describe the fluid dynamics principles governing the up-down oscillatory cycling of a bubble-covered, low-density, low-mass ball of material (referred to henceforth as a "fizz-ball") immersed inside a glass of bubbling (super-saturated) carbonated liquid. The bubbles serve to desaturate the liquid of excess CO[subscript 2]. The fizz-ball acts…

  18. Fizz-Ball Fizzics

    ERIC Educational Resources Information Center

    Moinester, Murray; Gerland, Lars; Liger-Belair, Gerard; Ocherashvili, Aharon

    2012-01-01

    We describe the fluid dynamics principles governing the up-down oscillatory cycling of a bubble-covered, low-density, low-mass ball of material (referred to henceforth as a "fizz-ball") immersed inside a glass of bubbling (super-saturated) carbonated liquid. The bubbles serve to desaturate the liquid of excess CO[subscript 2]. The fizz-ball acts…

  19. Ball Screw Actuator Including a Compliant Ball Screw Stop

    NASA Technical Reports Server (NTRS)

    Wingett, Paul T. (Inventor); Hanlon, Casey (Inventor)

    2015-01-01

    An actuator includes a ball nut, a ball screw, and a ball screw stop. The ball nut is adapted to receive an input torque and in response rotates and supplies a drive force. The ball screw extends through the ball nut and has a first end and a second end. The ball screw receives the drive force from the ball nut and in response selectively translates between a retract position and a extend position. The ball screw stop is mounted on the ball screw proximate the first end to translate therewith. The ball screw stop engages the ball nut when the ball screw is in the extend position, translates, with compliance, a predetermined distance toward the first end upon engaging the ball nut, and prevents further rotation of the ball screw upon translating the predetermined distance.

  20. Ball Screw Actuator Including a Compliant Ball Screw Stop

    NASA Technical Reports Server (NTRS)

    Wingett, Paul T. (Inventor); Hanlon, Casey (Inventor)

    2017-01-01

    An actuator includes a ball nut, a ball screw, and a ball screw stop. The ball nut is adapted to receive an input torque and in response rotates and supplies a drive force. The ball screw extends through the ball nut and has a first end and a second end. The ball screw receives the drive force from the ball nut and in response selectively translates between a retract position and a extend position. The ball screw stop is mounted on the ball screw proximate the first end to translate therewith. The ball screw stop engages the ball nut when the ball screw is in the extend position, translates, with compliance, a predetermined distance toward the first end upon engaging the ball nut, and prevents further rotation of the ball screw upon translating the predetermined distance.

  1. Balls on the Lawn

    NASA Astrophysics Data System (ADS)

    Mallows, Colin L.; Shapiro, Lou

    1999-03-01

    In the "tennis ball" problem we are given successive pairs of balls numbered (1,2), (3,4),... At each stage we throw one ball out of the window. After n stages some set of n balls is on the lawn. We find a generating function and a closed formula for the sequence 3, 23, 131, 664, 3166, 14545, 65187, 287060, 1247690,..., the n-th term of which gives the sum over all possible arrangements of the total of the numbers on the balls on the lawn. The problem has connections with "bicolored Motzkin paths" and the ballot problem.

  2. Common cardiac prosthetic valves. Radiologic identification and associated complications.

    PubMed

    Chun, P K; Nelson, W P

    1977-08-01

    The development of prosthetic heart valves has been an important advance in the treatment of patients with serious valvular cardiac disease. Because there are many types of prosthetic valves, we have prepared a diagram of the valves currently or previously used and list their potential complications. Prosthetic valves were identified according to photographic and radiologic features, valve replacement location, and reported associated complications. Data have been compiled in tabular form for quick reference; valves have been identified according to valve base, cage, and poppet. They may be categorized as caged-ball or low-profile valves. Such information helps to provide recognition of the valve that has been inserted and permits the clinician or radiologist to be alert to possible complications with the various prosthetic devices.

  3. Fast valve

    SciTech Connect

    Van Dyke, William J.

    1992-01-01

    A fast valve is disclosed that can close on the order of 7 milliseconds. It is closed by the force of a compressed air spring with the moving parts of the valve designed to be of very light weight and the valve gate being of wedge shaped with O-ring sealed faces to provide sealing contact without metal to metal contact. The combination of the O-ring seal and an air cushion create a soft final movement of the valve closure to prevent the fast air acting valve from having a harsh closing.

  4. Fast valve

    DOEpatents

    Van Dyke, W.J.

    1992-04-07

    A fast valve is disclosed that can close on the order of 7 milliseconds. It is closed by the force of a compressed air spring with the moving parts of the valve designed to be of very light weight and the valve gate being of wedge shaped with O-ring sealed faces to provide sealing contact without metal to metal contact. The combination of the O-ring seal and an air cushion create a soft final movement of the valve closure to prevent the fast air acting valve from having a harsh closing. 4 figs.

  5. Space Shuttle OMS engine valve technology. [Orbital Maneuvering System

    NASA Technical Reports Server (NTRS)

    Wichmann, H.

    1974-01-01

    Valve technology program to determine shutoff valve concepts suitable for the Orbital Maneuvering System (OMS) engine of the Space Shuttle. The tradeoff studies selected the electric torque motor operated dual poppet and ball valves as the most desirable valve concepts for the OMS Engine Shutoff Valve. A prototype of one of these concepts was built and subjected to a design verification program. A number of unique features were designed to include the required contamination insensitivity, operating fluid compatibility, decontamination capability, minimum maintenance requirement and long service life capability.

  6. The bounce of a ball

    NASA Astrophysics Data System (ADS)

    Cross, Rod

    1999-03-01

    In this paper, the dynamics of a bouncing ball is described for several common ball types having different bounce characteristics. Results are presented for a tennis ball, a baseball, a golf ball, a superball, a steel ball bearing, a plasticene ball, and a silly putty ball. The plasticene ball was studied as an extreme case of a ball with a low coefficient of restitution (in fact zero, since the collision is totally inelastic) and the silly putty ball was studied because it has unusual elastic properties. The first three balls were studied because of their significance in the physics of sports. For each ball, a dynamic hysteresis curve is presented to show how energy is lost during and after the collision. The measurement technique is quite simple, it is suited for undergraduate laboratory experiments, and it may provide a useful method to test and approve balls for major sporting events.

  7. Ball Bearing Mechanics

    NASA Technical Reports Server (NTRS)

    Hamrock, B. J.; Dowson, D.

    1981-01-01

    Load-deflection relationships for different types of elliptical contacts such as those found in a ball bearing are developed. Simplified expressions that allow quick calculations of deformation to be made simply from a knowledge of the applied load, the material properties, and the geometry of the contacting elements are presented. Ball bearings subjected to radial, thrust and combined ball loads are analyzed. A design criterion for fatigue life of ball bearings is developed. The section of a satisfactory lubricant, as well as describing systems that provide a constant flow of lubricant to the contact, is considered.

  8. Birth of ball lightning

    NASA Astrophysics Data System (ADS)

    Lowke, J. J.; Smith, D.; Nelson, K. E.; Crompton, R. W.; Murphy, A. B.

    2012-10-01

    Many observations of ball lightning report a ball of light, about 10 cm in diameter, moving at about walking speed, lasting up to 20 s and frequently existing inside of houses and even aeroplanes. The present paper reports detailed observations of the initiation or birth of ball lightning. In two cases, navigation crew of aircraft saw ball lightning form at the windscreen inside the cockpit of their planes. In the first case, the ball lightning occurred during a thunderstorm, with much lightning activity outside of the plane. In the second case, large "horns" of electrical corona were seen outside of the plane at the surface of the radome, just prior to the formation of the ball lightning. A third case reports ball lightning formed inside of a house, during a thunderstorm, at a closed glass window. It is proposed, based on two-dimensional calculations of electron and ion transport, that ball lightning in these cases is driven and formed by atmospheric ions impinging and collecting on the insulating surface of the glass or Perspex windows. This surface charge can produce electric fields inside of the cockpit or room sufficient to sustain an electric discharge. Charges of opposite sign to those outside of the window accumulate on the inside surface of the glass, leaving a ball of net charge moving inside of the cockpit or room to produce a pulsed discharge on a microsecond time scale.

  9. Physics of ball sports

    NASA Astrophysics Data System (ADS)

    Cohen, C.; Clanet, C.

    2016-06-01

    Ball sports have been part of human history for thousands of years [1]. Nowadays, 13 of them are part of the Olympic games (badminton, basketball, beach volley, football/soccer, golf, handball, hockey, rugby, table tennis, tennis, volleyball, water polo, ice hockey). All these games differ by launcher (hand, club, racket, bat), ball (size, shape and mass), pitch size and number of players. These differences induce different ball velocities. Apart from the velocities and the way to maximize them, we discuss in this article the ball trajectories and their impact on the size of sports fields.

  10. Depressurization valve

    DOEpatents

    Skoda, G.I.

    1989-03-28

    A depressurization valve for use in relieving completely the pressure in a simplified boiling water reactor is disclosed. The normally closed and sealed valve is provided with a valve body defining a conduit from an outlet of a manifold from the reactor through a valve seat. A closing valve disk is configured for fitting to the valve seat to normally close the valve. The seat below the disk is provided with a radially extending annulus extending a short distance into the aperture defined by the seat. The disk is correspondingly provided with a longitudinally extending annulus that extends downwardly through the aperture defined by the seat towards the high pressure side of the valve body. A ring shaped membrane is endlessly welded to the seat annulus and to the disk annulus. The membrane is conformed over the confronted surface of the seat and disk in a C-sectioned configuration to seal the depressurization valve against the possibility of weeping. The disk is held to the closed position by an elongate stem extending away from the high pressure side of the valve body. The stem has a flange configured integrally to the stem for bias by two springs. The first spring acts from a portion of the housing overlying the disk on the stem flange adjacent the disk. This spring urges the stem and attached disk away from the seat and thus will cause the valve to open at any pressure. A second spring-preferably of the Belleville variety-acts on a latch plate surrounding and freely moving relative to the end of the stem. This second spring overcomes the bias of the first spring and any pressure acting upon the disk. This Belleville spring maintains through its spring force the valve in the closed position. At the same time, the latch plate with its freedom of movement relative to the stem allows the stem to thermally expand during valve temperature excursion.

  11. Borner Ball Neutron Detector

    NASA Technical Reports Server (NTRS)

    2002-01-01

    The Bonner Ball Neutron Detector measures neutron radiation. Neutrons are uncharged atomic particles that have the ability to penetrate living tissues, harming human beings in space. The Bonner Ball Neutron Detector is one of three radiation experiments during Expedition Two. The others are the Phantom Torso and Dosimetric Mapping.

  12. Ball Collision Experiments

    ERIC Educational Resources Information Center

    Cross, R.

    2015-01-01

    Experiments are described on collisions between two billiard balls and between a bat and a ball. The experiments are designed to extend a student's understanding of collision events and could be used either as a classroom demonstration or for a student project.

  13. Ball Collision Experiments

    ERIC Educational Resources Information Center

    Cross, R.

    2015-01-01

    Experiments are described on collisions between two billiard balls and between a bat and a ball. The experiments are designed to extend a student's understanding of collision events and could be used either as a classroom demonstration or for a student project.

  14. Tunguska dark matter ball

    NASA Astrophysics Data System (ADS)

    Froggatt, C. D.; Nielsen, H. B.

    2015-04-01

    It is suggested that the Tunguska event in June 1908 was due to a cm-large ball of a condensate of bound states of 6 top and 6 antitop quarks containing highly compressed ordinary matter. Such balls are supposed to make up the dark matter as we earlier proposed. The expected rate of impact of this kind of dark matter ball with the earth seems to crudely match a time scale of 200 years between the impacts. The main explosion of the Tunguska event is explained in our picture as material coming out from deep within the earth, where it has been heated and compressed by the ball penetrating to a depth of several thousand km. Thus the effect has some similarity with volcanic activity as suggested by Kundt. We discuss the possible identification of kimberlite pipes with earlier Tunguska-like events. A discussion of how the dark matter balls may have formed in the early universe is also given.

  15. Problem: Heart Valve Stenosis

    MedlinePlus

    ... valve . Learn about the different types of stenosis: Aortic stenosis Tricuspid stenosis Pulmonary stenosis Mitral stenosis Outlook for ... Disease "Innocent" Heart Murmur Problem: Valve Stenosis - Problem: Aortic Valve Stenosis - Problem: Mitral Valve Stenosis - Problem: Tricuspid Valve Stenosis - ...

  16. Happy Balls, Unhappy Balls, and Newton's Cradle

    ERIC Educational Resources Information Center

    Kagan, David

    2010-01-01

    The intricacies of Newton's Cradle are well covered in the literature going as far back as the time of Newton! These discussions generally center on the highly elastic collisions of metal spheres. Thanks to the invention of happy and unhappy balls, you can build and study the interaction of less elastic systems (see Fig. 1).

  17. Happy Balls, Unhappy Balls, and Newton's Cradle

    ERIC Educational Resources Information Center

    Kagan, David

    2010-01-01

    The intricacies of Newton's Cradle are well covered in the literature going as far back as the time of Newton! These discussions generally center on the highly elastic collisions of metal spheres. Thanks to the invention of happy and unhappy balls, you can build and study the interaction of less elastic systems (see Fig. 1).

  18. Depressurization valve

    DOEpatents

    Skoda, George I.

    1989-01-01

    A depressurization valve for use in relieving completely the pressure in a simplified boiling water reactor is disclosed. The normally closed and sealed valve is provided with a valve body defining a conduit from an outlet of a manifold from the reactor through a valve seat. A closing valve disk is configured for fitting to the valve seat to normally close the valve. The seat below the disk is provided with a radially extending annulus extending a short distance into the aperture defined by the seat. The disk is correspondingly provided with a longitudinally extending annulus that extends downwardly through the aperture defined by the seat towards the high pressure side of the valve body. A ring shaped membrane is endlessly welded to the seat annulus and to the disk annulus. The membrane is conformed over the confronted surface of the seat and disk in a C-sectioned configuration to seal the depressurization valve against the possibility of weeping. The disk is held to the closed position by an elongate stem extending away from the high pressure side of the valve body. The stem has a flange configured integrally to the stem for bias by two springs. The first spring acts from a portion of the housing overlying the disk on the stem flange adjacent the disk. This spring urges the stem and attached disk away from the seat and thus will cause the valve to open at any pressure. A second spring--preferably of the Belleville variety--acts on a latch plate surrounding and freely moving relative to the end of the stem. This second spring overcomes the bias of the first spring and any pressure acting upon the disk. This Belleville spring maintains through its spring force the valve in the closed position. At the same time, the latch plate with its freedom of movement relative to the stem allows the stem to thermally expand during valve temperature excursion. The latch plate in surrounding the stem is limited in its outward movement by a boss attached to the stem at the end of

  19. Introduction to ball bearings

    NASA Technical Reports Server (NTRS)

    Hamrock, B. J.; Dowson, D.

    1981-01-01

    The purpose of a ball bearing is to provide a relative positioning and rotational freedom while transmitting a load between two structures, usually a shaft and a housing. For high rotational speeds (e.g., in gyroscope ball bearings) the purpose can be expanded to include rotational freedom with practically no wear in the bearing. This condition can be achieved by separating the bearing parts with a coherent film of fluid known as an elastohydrodynamic film. This film can be maintained not only when the bearing carries the load on a shaft, but also when the bearing is preloaded to position the shaft to within micro- or nano-inch accuracy and stability. Background information on ball bearings is provided, different types of ball bearings and their geometry and kinematics are defined, bearing materials, manufacturing processes, and separators are discussed. It is assumed, for the purposes of analysis, that the bearing carries no load.

  20. Space Balls Artist Concept

    NASA Image and Video Library

    2010-07-22

    NASA Spitzer Space Telescope has at last found buckyballs resembling soccer balls in space shown in this artist concept using Hubble picture of the NGC 2440 nebula. Hubble image cred: NASA, ESA, STScI

  1. Super Ball Bot

    NASA Image and Video Library

    Tensegrity Robot: Child's Play or Space Tech? Super Ball Bot is an all-in-one landing and mobility platform based on tensegrity structures, allowing for lower-cost, and more reliable planetary miss...

  2. Nuclear radiation actuated valve

    DOEpatents

    Christiansen, David W.; Schively, Dixon P.

    1985-01-01

    A nuclear radiation actuated valve for a nuclear reactor. The valve has a valve first part (such as a valve rod with piston) and a valve second part (such as a valve tube surrounding the valve rod, with the valve tube having side slots surrounding the piston). Both valve parts have known nuclear radiation swelling characteristics. The valve's first part is positioned to receive nuclear radiation from the nuclear reactor's fuel region. The valve's second part is positioned so that its nuclear radiation induced swelling is different from that of the valve's first part. The valve's second part also is positioned so that the valve's first and second parts create a valve orifice which changes in size due to the different nuclear radiation caused swelling of the valve's first part compared to the valve's second part. The valve may be used in a nuclear reactor's core coolant system.

  3. Beware of the B(e)all valve: mistaken valve identity, 30-year survival, and valve replacement.

    PubMed

    Topaz, On; Rutherford, Molly S; Mackey-Bojack, Shannon; Polkampally, Pritam R; Topaz, Allyne; Prinz, Andreas; Szentpetery, Szabolcs

    2010-01-01

    Effective management of patients after the implantation of mechanical cardiac valves includes correct recognition of each valve and its related complications. Herein, we present the case of a patient who had undergone implantation of a floating-disc Beall-Surgitool mitral valve in 1976 and developed multiple valve-related complications. Over 30 years and in multiple medical centers, the device was mistakenly assumed to be a "ball" valve. The correct identification of the prosthesis led to the recognition of valvular failure, and the patient underwent its replacement with an On-X bileaflet carbon valve. Pathologic and microscopic examination of the explanted Beall valve showed massive pannus formation that extended over the sewing cuff on the atrial and ventricular side, preventing complete disc closure; disrupted fabric coating of the sewing ring, with exposure of the underlying metal; and a marked inflammatory reaction. We report one of the longest intervals on record between the implantation and replacement of a Beall-Surgitool valve.

  4. Nanostructured and Conventional Cr2O3, TiO2, and TiO2-Cr2O3 Thermal-Sprayed Coatings for Metal-Seated Ball Valve Applications in Hydrometallurgy

    NASA Astrophysics Data System (ADS)

    Vernhes, Luc; Bekins, Craig; Lourdel, Nicolas; Poirier, Dominique; Lima, Rogerio S.; Li, Duanjie; Klemberg-Sapieha, Jolanta E.

    2016-06-01

    A detailed characterization project was undertaken by Velan, an international industrial valve designer and manufacturer, in collaboration with the National Research Council of Canada, Boucherville, and Polytechnique Montréal. The purpose was to assess the mechanical and tribological resistances of promising ceramic coatings for hydrometallurgy applications, including a novel n-TiO2-Cr2O3 blend. Hardness and shear strength were determined using microhardness indentation testers and universal tensile testing equipment. Wear resistance of the coatings under sliding wear, abrasion, and galling conditions were measured by standard pin-on-disk tests, abrasion tests, and custom-designed galling tests. The main result is that the synergy between Cr2O3 and n-TiO2 produced abrasion performance exceeding that of these materials alone. Also, an optimized balance between the hard and brittle Cr2O3 phases and the soft and ductile n-TiO2 phases resulted in higher abrasion, sliding, and galling resistance. The novel n-TiO2-Cr2O3 blend is therefore considered as a promising evolution of the current TiO2-Cr2O3 blend.

  5. Aerodynamics of sports balls

    NASA Technical Reports Server (NTRS)

    Mehta, R. D.

    1985-01-01

    Research data on the aerodynamic behavior of baseballs and cricket and golf balls are summarized. Cricket balls and baseballs are roughly the same size and mass but have different stitch patterns. Both are thrown to follow paths that avoid a batter's swing, paths that can curve if aerodynamic forces on the balls' surfaces are asymmetric. Smoke tracer wind tunnel tests and pressure taps have revealed that the unbalanced side forces are induced by tripping the boundary layer on the seam side and producing turbulence. More particularly, the greater pressures are perpendicular to the seam plane and only appear when the balls travel at velocities high enough so that the roughness length matches the seam heigh. The side forces, once tripped, will increase with spin velocity up to a cut-off point. The enhanced lift coefficient is produced by the Magnus effect. The more complex stitching on a baseball permits greater variations in the flight path curve and, in the case of a knuckleball, the unsteady flow effects. For golf balls, the dimples trip the boundary layer and the high spin rate produces a lift coefficient maximum of 0.5, compared to a baseball's maximum of 0.3. Thus, a golf ball travels far enough for gravitational forces to become important.

  6. Aerodynamics of sports balls

    NASA Technical Reports Server (NTRS)

    Mehta, R. D.

    1985-01-01

    Research data on the aerodynamic behavior of baseballs and cricket and golf balls are summarized. Cricket balls and baseballs are roughly the same size and mass but have different stitch patterns. Both are thrown to follow paths that avoid a batter's swing, paths that can curve if aerodynamic forces on the balls' surfaces are asymmetric. Smoke tracer wind tunnel tests and pressure taps have revealed that the unbalanced side forces are induced by tripping the boundary layer on the seam side and producing turbulence. More particularly, the greater pressures are perpendicular to the seam plane and only appear when the balls travel at velocities high enough so that the roughness length matches the seam heigh. The side forces, once tripped, will increase with spin velocity up to a cut-off point. The enhanced lift coefficient is produced by the Magnus effect. The more complex stitching on a baseball permits greater variations in the flight path curve and, in the case of a knuckleball, the unsteady flow effects. For golf balls, the dimples trip the boundary layer and the high spin rate produces a lift coefficient maximum of 0.5, compared to a baseball's maximum of 0.3. Thus, a golf ball travels far enough for gravitational forces to become important.

  7. Aerodynamics of sports balls

    NASA Astrophysics Data System (ADS)

    Mehta, R. D.

    Research data on the aerodynamic behavior of baseballs and cricket and golf balls are summarized. Cricket balls and baseballs are roughly the same size and mass but have different stitch patterns. Both are thrown to follow paths that avoid a batter's swing, paths that can curve if aerodynamic forces on the balls' surfaces are asymmetric. Smoke tracer wind tunnel tests and pressure taps have revealed that the unbalanced side forces are induced by tripping the boundary layer on the seam side and producing turbulence. More particularly, the greater pressures are perpendicular to the seam plane and only appear when the balls travel at velocities high enough so that the roughness length matches the seam heigh. The side forces, once tripped, will increase with spin velocity up to a cut-off point. The enhanced lift coefficient is produced by the Magnus effect. The more complex stitching on a baseball permits greater variations in the flight path curve and, in the case of a knuckleball, the unsteady flow effects. For golf balls, the dimples trip the boundary layer and the high spin rate produces a lift coefficient maximum of 0.5, compared to a baseball's maximum of 0.3. Thus, a golf ball travels far enough for gravitational forces to become important.

  8. Analysis of hydrodynamic losses for various types of aortic valves

    NASA Astrophysics Data System (ADS)

    Starobin, I. M.; Lupachev, S. P.; Dolgopolov, R. V.; Zaiko, V. M.; Kas'yanov, V. A.; Mungalov, D. D.; Morov, G. V.

    1985-05-01

    The creation of an automated computer-controlled hydraulic stand made it possible to measure the main hydrodynamic parameters of the flow through the investigated HVP and to determine the coefficients of Eq. (2) of fluid flow in the test chamber of the stand. The coefficients found can serve as a criterion of a comparative assessment of the hydrodynamics of HVPs. An analysis of the coefficients showed that the main contribution to pressure losses across ball and disc valves is made by viscous and convective effects. An analysis of inertial losses confirmed the presence of oscillations of the ball closing elements of the AKCh-3-06 valve around the props of the stroke limiters and made it possible to assess them quantitatively. For leaflet valves the contribution of inertial losses to the total pressure losses is more considerable than in the case of disc and ball valves both in the regime of an increase of power of the output and in the regime of a constant power. The mechanical properties of the material of leaflet valves have an effect on the hydrodynamic characteristics. The advantage of the investigated leaflet valves consists not only in that they have smaller total hydraulic losses compared with the other valves, but also in that they provide a high amplitude of pulsations of the blood stream in the case of insufficient contractility of the heart.

  9. Glovebox pressure relief and check valve

    SciTech Connect

    Blaedel, K.L.

    1986-03-17

    This device is a combined pressure relief valve and check valve providing overpressure protection and preventing back flow into an inert atmosphere enclosure. The pressure relief is embodied by a submerged vent line in a mercury reservior, the releif pressure being a function of the submerged depth. The pressure relief can be vented into an exhaust system and the relieving pressure is only slightly influenced by the varying pressure in the exhaust system. The check valve is embodied by a ball which floats on the mercury column and contacts a seat whenever vacuum exists within the glovebox enclosure. Alternatively, the check valve is embodied by a vertical column of mercury, the maximum back pressure being a function of the height of the column of mercury.

  10. Aortic insufficiency. A result of intermittent migration of aortic valve prosthesis poppet.

    PubMed

    Kunstadt, D; Adeyemo, A; Clauss, R H

    1976-06-28

    A bizarre mechanism of aortic valve incompetence was observed when the occluder of a Braunwald-Cutter aortic valve prosthesis decreased in diameter, volume, and weight, and from time to time fell into the left ventricle. The patient's symptoms were palpitation, coughing, chocking sensations, and fright. An operation disclosed a small, smooth ball with disrupted cloth on all the struts. The residual torn mesh was removed, and the ball was replaced.

  11. Aortic Valve Regurgitation

    MedlinePlus

    ... valve. Also, a narrowing of the aortic valve (aortic stenosis) can be associated with leaking. High blood pressure (hypertension). High blood pressure may stretch the root of the aorta where the aortic valve sits. The valve flaps ( ...

  12. Aortic Valve Stenosis

    MedlinePlus

    ... pulmonary valve and aortic valve. Each valve has flaps (cusps or leaflets) that open and close once ... valve consists of three tightly fitting, triangular-shaped flaps of tissue called cusps. Some children are born ...

  13. Hex ball torque test

    NASA Technical Reports Server (NTRS)

    Robinson, B. A.; Foster, C. L.

    1986-01-01

    A series of torque tests were performed on four flight-type hex ball universal joints in order to characterize and determine the actual load-carrying capability of this device. The universal joint is a part of manual actuation rods for scientific instruments within the Hubble Space Telescope. It was found that the hex ball will bind slightly during the initial load application. This binding did not affect the function of the universal joint, and the units would wear-in after a few additional loading cycles. The torsional yield load was approximately 50 ft-lb, and was consistent among the four test specimens. Also, the torque required to cause complete failure exceeded 80 ft-lb. It is concluded that the hex ball universal joint is suitable for its intended applications.

  14. Wear resistant valve

    NASA Technical Reports Server (NTRS)

    Perkins, Gerald S. (Inventor)

    1980-01-01

    A valve which is resistant to wear caused by particles trapped between the valve seat and the valve member or poppet when the valve closes, including an outlet for directing washing fluid at the valve seat and/or sealing face of the poppet and means for supplying pressured fluid to the outlet at the time when the valve is closing.

  15. Split Q-balls

    NASA Astrophysics Data System (ADS)

    Bazeia, D.; Losano, L.; Marques, M. A.; Menezes, R.

    2017-02-01

    We investigate the presence of non-topological solutions of the Q-ball type in (1 , 1) spacetime dimensions. The model engenders the global U (1) symmetry and is of the k-field type, since it contains a new term, of the fourth-order power in the derivative of the complex scalar field. It supports analytical solution of the Q-ball type which is stable quantum mechanically. The new solution engenders an interesting behavior, with the charge and energy densities unveiling a splitting profile.

  16. A calcified polymeric valve for valve-in-valve applications.

    PubMed

    Falahatpisheh, Ahmad; Morisawa, Daisuke; Toosky, Taraz T; Kheradvar, Arash

    2017-01-04

    The prevalence of aortic valve stenosis (AS) is increasing in the aging society. More recently, novel treatments and devices for AS, especially transcatheter aortic valve replacement (TAVR) have significantly changed the therapeutic approach to this disease. Research and development related to TAVR require testing these devices in the calcified heart valves that closely mimic a native calcific valve. However, no animal model of AS has yet been available. Alternatively, animals with normal aortic valve that are currently used for TAVR experiments do not closely replicate the aortic valve pathology required for proper testing of these devices. To solve this limitation, for the first time, we developed a novel polymeric valve whose leaflets possess calcium hydroxyapatite inclusions immersed in them. This study reports the characteristics and feasibility of these valves. Two types of the polymeric valve, i.e., moderate and severe calcified AS models were developed and tested by deploying a transcatheter valve in those and measuring the related hemodynamics. The valves were tested in a heart flow simulator, and were studied using echocardiography. Our results showed high echogenicity of the polymeric valve, that was correlated to the severity of the calcification. Aortic valve area of the polymeric valves was measured, and the severity of stenosis was defined according to the clinical guidelines. Accordingly, we showed that these novel polymeric valves closely mimic AS, and can be a desired cost-saving solution for testing the performance of the transcatheter aortic valve systems in vitro.

  17. 49 CFR 236.383 - Valve locks, valves, and valve magnets.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Valve locks, valves, and valve magnets. 236.383... Inspection and Tests § 236.383 Valve locks, valves, and valve magnets. Valve locks on valves of the non-cut-off type shall be tested at least once every three months, and valves and valve magnets shall...

  18. 49 CFR 236.383 - Valve locks, valves, and valve magnets.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Valve locks, valves, and valve magnets. 236.383... Inspection and Tests § 236.383 Valve locks, valves, and valve magnets. Valve locks on valves of the non-cut-off type shall be tested at least once every three months, and valves and valve magnets shall...

  19. 49 CFR 236.383 - Valve locks, valves, and valve magnets.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Valve locks, valves, and valve magnets. 236.383... Inspection and Tests § 236.383 Valve locks, valves, and valve magnets. Valve locks on valves of the non-cut-off type shall be tested at least once every three months, and valves and valve magnets shall...

  20. 49 CFR 236.383 - Valve locks, valves, and valve magnets.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Valve locks, valves, and valve magnets. 236.383... Inspection and Tests § 236.383 Valve locks, valves, and valve magnets. Valve locks on valves of the non-cut-off type shall be tested at least once every three months, and valves and valve magnets shall...

  1. 49 CFR 236.383 - Valve locks, valves, and valve magnets.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Valve locks, valves, and valve magnets. 236.383... Inspection and Tests § 236.383 Valve locks, valves, and valve magnets. Valve locks on valves of the non-cut-off type shall be tested at least once every three months, and valves and valve magnets shall...

  2. Gate valve and motor-operator research findings

    SciTech Connect

    Steele, R. Jr.; DeWall, K.G.; Watkins, J.C.; Russell, M.J.; Bramwell, D.

    1995-09-01

    This report provides an update on the valve research being sponsored by the US Nuclear Regulatory Commission (NRC) and conducted at the Idaho National Engineering Laboratory (INEL). The research addresses the need to provide assurance that motor-operated valves can perform their intended safety function, usually to open or close against specified (design basis) flow and pressure loads. This report describes several important developments: Two methods for estimating or bounding the design basis stem factor (in rising-stem valves), using data from tests less severe than design basis tests; a new correlation for evaluating the opening responses of gate valves and for predicting opening requirements; an extrapolation method that uses the results of a best effort flow test to estimate the design basis closing requirements of a gate valve that exhibits atypical responses (peak force occurs before flow isolation); and the extension of the original INEL closing correlation to include low- flow and low-pressure loads. The report also includes a general approach, presented in step-by-step format, for determining operating margins for rising-stem valves (gate valves and globe valves) as well as quarter-turn valves (ball valves and butterfly valves).

  3. Worcester 1 Inch Solenoid Actuated Gas Operated SCHe System Valves

    SciTech Connect

    MISKA, C.R.

    2000-09-03

    1 inch gas-operated full-port ball valves incorporate a solenoid and limit switches as integral parts of the actuator. These valves are normally open and fail safe to the open position (GOV-1*02 and 1*06 fail closed) to provide a flow path of helium gas to the MCO under helium purge and off-normal conditions when the MCO is isolated.

  4. Magnetically driven cold valve for {sup 4}He

    SciTech Connect

    Bueno, J.; Blaauwgeers, R.; Partapsing, R.; Taminiau, I.; Jochemsen, R.

    2006-08-15

    We have designed a low temperature valve for liquid helium, which uses a magnetic field gradient and a permanent magnet to close. For closing, it presses a small ruby ball onto a Torlon seat. We present a small valve that is easy to build and easily controlled via two wires. It has a fast response, reliable, and has the advantage that there is no dead volume change on closing and no additional helium line is required to operate.

  5. The Mathematics of Bouncing Balls.

    ERIC Educational Resources Information Center

    Martin, Kathleen

    1989-01-01

    Describes an activity which uses the computer to produce an environment that encourages an inductive reasoning approach to ratio and proportion through a billiard ball simulation. Provides examples of graphs and bouncing ball data. (RT)

  6. Piezoelectric valve

    SciTech Connect

    Petrenko, Serhiy Fedorovich

    2013-01-15

    A motorized valve has a housing having an inlet and an outlet to be connected to a pipeline, a saddle connected with the housing, a turn plug having a rod, the turn plug cooperating with the saddle, and a drive for turning the valve body and formed as a piezoelectric drive, the piezoelectric drive including a piezoelectric generator of radially directed standing acoustic waves, which is connected with the housing and is connectable with a pulse current source, and a rotor operatively connected with the piezoelectric generator and kinematically connected with the rod of the turn plug so as to turn the turn plug when the rotor is actuated by the piezoelectric generator.

  7. Balls and Spheres

    ERIC Educational Resources Information Center

    Szekely, George

    2011-01-01

    This article describes an art lesson that allows students to set up and collect sphere canvases. Spheres move art away from a rectangular canvas into a dimension that requires new planning and painting. From balls to many other spherical canvases that bounce, roll, float and fly, art experiences are envisioned by students. Even if adults recognize…

  8. Balls and Spheres

    ERIC Educational Resources Information Center

    Szekely, George

    2011-01-01

    This article describes an art lesson that allows students to set up and collect sphere canvases. Spheres move art away from a rectangular canvas into a dimension that requires new planning and painting. From balls to many other spherical canvases that bounce, roll, float and fly, art experiences are envisioned by students. Even if adults recognize…

  9. Excess flow shutoff valve

    DOEpatents

    Kiffer, Micah S.; Tentarelli, Stephen Clyde

    2016-02-09

    Excess flow shutoff valve comprising a valve body, a valve plug, a partition, and an activation component where the valve plug, the partition, and activation component are disposed within the valve body. A suitable flow restriction is provided to create a pressure difference between the upstream end of the valve plug and the downstream end of the valve plug when fluid flows through the valve body. The pressure difference exceeds a target pressure difference needed to activate the activation component when fluid flow through the valve body is higher than a desired rate, and thereby closes the valve.

  10. Visual Skills: Watch the Ball?

    ERIC Educational Resources Information Center

    Moen, Sue

    1989-01-01

    In tennis as well as in other racket/paddle sports, simply watching the ball does not guarantee success in hitting the ball to the desired location. Teachers and coaches should teach players to integrate available visual, spatial, and kinesthetic information. Several drills for good ball contact are outlined. (IAH)

  11. Visual Skills: Watch the Ball?

    ERIC Educational Resources Information Center

    Moen, Sue

    1989-01-01

    In tennis as well as in other racket/paddle sports, simply watching the ball does not guarantee success in hitting the ball to the desired location. Teachers and coaches should teach players to integrate available visual, spatial, and kinesthetic information. Several drills for good ball contact are outlined. (IAH)

  12. Detonator-activated ball shutter

    DOEpatents

    McWilliams, Roy A.; von Holle, William G.

    1983-01-01

    A detonator-activated ball shutter for closing an aperture in about 300.mu. seconds. The ball shutter containing an aperture through which light, etc., passes, is closed by firing a detonator which propels a projectile for rotating the ball shutter, thereby blocking passage through the aperture.

  13. Detonator-activated ball shutter

    DOEpatents

    McWilliams, R.A.; Holle, W.G. von.

    1983-08-16

    A detonator-activated ball shutter for closing an aperture in about 300[mu] seconds. The ball shutter containing an aperture through which light, etc., passes, is closed by firing a detonator which propels a projectile for rotating the ball shutter, thereby blocking passage through the aperture. 3 figs.

  14. Valve Disease

    MedlinePlus

    ... medicines for the rest of their lives. Valve surgery is usually an open heart technique. This means that surgeons use a heart-lung machine, because the heart must stop beating for a short time during surgery. In some patients, surgeons can repair or replace ...

  15. OMS engine shutoff valve and actuation system design and evaluation. [for space shuttles

    NASA Technical Reports Server (NTRS)

    Wichmann, H.

    1974-01-01

    Shutoff valve and actuation system concepts that are most suitable for the Orbital Maneuvering Systems engine application were determined. Emphasis was placed on the ten year and 100 mission life requirement, propellant and propellant residue compatibility and weight. It was found that poppet or ball valves utilizing electric or electropneumatic actuation were most applicable. Preliminary design layouts of a number of valve and actuation concepts were prepared and analyzed to make the optimum concept selection. Pneumatic actuation systems were required to feature their own pneumatic supply so that for the quad redundant valve, it was necessary to include two pneumatic supply systems, one for each of the series legs of the quad redundant package. The requirement for the pneumatic package placed heavy reliability, weight, and maintenance penalties upon electropneumatic actuation systems. The two valve and actuation systems concepts selected featured electric torque motor operation and a poppet as well as a ball valve concept with a retractable seal.

  16. [Thrombolysis in mechanical prosthetic valve thrombosis. Its management with streptokinase].

    PubMed

    Solorio, S; Sánchez, H; Madrid, R; Badui, E; Valdespino, A; Murillo, H; Rangel, A; Enciso, R

    1994-01-01

    We present the first experience in Mexico in 10 patients, 9 female and 1 male with an average age of 42.5 years. All patients had clinical, echocardiographic and fluoroscopic criteria of dysfunctioning mechanical valvular prosthesis due to thrombosis (9 Sorin type and 1 Starr-Edwards). None of the patients had contraindications for thrombolytic therapy. All cases were treated with intravenous streptokinase: 250,000 U in 30 minutes followed by an infusion of 100,000 U per hour, always under clinical, echocardiographic and fluoroscopic control every 2 and 24 hours respectively until the normalization of the clinical and hemodynamic parameters with a top limit of 72 hour. The average duration of the thrombolysis was 54 +/- 6.1 hours with an average total doses of 5' 200,000 U of streptokinase. In 90% of the cases there was an increase in the valvular area: mitral (n = 7), from 1.02 +/- 0.21 to 1.75 +/- 0.36 cm2 (p < 0.001), while the mean transvalvular gradient decreased from 10.42 +/- 3.77 to 3.42 +/- 0.975 mmHg (p < 0.001); the systolic pulmonary artery pressure also decreased from 53.7 +/- 15.29 to 35 +/- 2 mmHg (p < 0.001). In the tricuspid prosthesis (n = 2) the average valvular area was increased from 0.8 +/- 0.44 to 1.55 +/- 0.77 cm2, decreasing proportionally the mean transvalvular gradient from 12.5 +/- 2 to 4.5 +/- 3.5 mmHg with no changes in the systolic pressure of the pulmonary artery. In the Starr-Edwards prosthesis in aortic position (n = 1), no hemodynamic changes were observed.(ABSTRACT TRUNCATED AT 250 WORDS)

  17. Aperture Valve for the Mars Organic Molecule Analyzer (MOMA)

    NASA Technical Reports Server (NTRS)

    Hakun, Claef F.; Engler, Charles D.; Barber, Willie E.; Canham, John S.

    2014-01-01

    NASA's participation in the multi-nation ExoMars 2018 Rover mission includes a critical astrobiology Mass Spectrometer Instrument on the Rover called the Mars Organic Molecule Analyzer (MOMA). The Aperture Valve is a critical electromechanical valve used by the Mass Spectrometer to facilitate the transfer of ions from Martian soil to the Mass Spectrometer for analysis. The MOMA Aperture Valve development program will be discussed in terms of the Initial valve design and subsequent improvements that resulted from prototype testing. The Initial Aperture Valve concept seemed promising, based on calculations and perceived merits. However, performance results of this design were disappointing, due to delamination of TiN and DLC coatings applied to the Titanium base metals, causing debris from the coatings to seize the valve. While peer reviews and design trade studies are important forums to vet a concept design, results from testing should not be underestimated.Despite the lack of development progress to meet requirements, valuable information from weakness discovered in the Initial Valve design was used to develop a second, more robust Aperture valve. Based on a check-ball design, the ETU flight valve design resulted in significantly less surface area to create the seal. Moreover, PVD coatings were eliminated in favor of hardened, nonmagnetic corrosion resistant alloys. Test results were impressive, with the valve achieving five orders of magnitude better sealing leak rate over end of life requirements. Cycle life was equally impressive, achieving 280,000 cycles without failure.

  18. Aperture Valve for the Mars Organic Molecule Analyzer (MOMA)

    NASA Technical Reports Server (NTRS)

    Engler, Charles; Canham, John

    2014-01-01

    NASA's participation in the multi-nation ExoMars 2018 Rover mission includes a critical astrobiology Mass Spectrometer Instrument on the Rover called the Mars Organic Molecule Analyzer (MOMA). The Aperture Valve is a critical electromechanical valve used by the Mass Spectrometer to facilitate the transfer of ions from Martian soil to the Mass Spectrometer for analysis. The MOMA Aperture Valve development program will be discussed in terms of the initial valve design and subsequent improvements that resulted from prototype testing. The initial Aperture Valve concept seemed promising, based on calculations and perceived merits. However, performance results of this design were disappointing, due to delamination of TiN and DLC coatings applied to the titanium base metals, causing debris from the coatings to seize the valve. While peer reviews and design trade studies are important forums to vet a concept design, results from testing should not be underestimated. Despite the lack of development progress to meet requirements, valuable information from weakness discovered in the initial Valve design was used to develop a second, more robust Aperture Valve. Based on a check-ball design, the ETU / flight valve design resulted in significantly less surface area to create the seal. Moreover, PVD coatings were eliminated in favor of hardened, non-magnetic corrosion resistant alloys. Test results were impressive, with the valve achieving five orders of magnitude better sealing leak rate over end of life requirements. Cycle life was equally impressive, achieving 280,000 cycles without failure.

  19. Aperture Valve for the Mars Organic Molecule Analyzer (MOMA)

    NASA Technical Reports Server (NTRS)

    Engler, Charles D.; Canham, John S.

    2014-01-01

    NASA's participation in the multi-nation ExoMars 2018 Rover mission includes a critical astrobiology Mass Spectrometer Instrument on the Rover called the Mars Organic Molecule Analyzer (MOMA). The Aperture Valve is a critical electromechanical valve used by the Mass Spectrometer to facilitate the transfer of ions from Martian soil to the Mass Spectrometer for analysis. The MOMA Aperture Valve development program will be discussed in terms of the Initial valve design and subsequent improvements that resulted from prototype testing. The Initial Aperture Valve concept seemed promising, based on calculations and perceived merits. However, performance results of this design were disappointing, due to delamination of TiN and DLC coatings applied to the Titanium base metals, causing debris from the coatings to seize the valve. While peer reviews and design trade studies are important forums to vet a concept design, results from testing should not be underestimated. Despite the lack of development progress to meet requirements, valuable information from weakness discovered in the Initial Valve design was used to develop a second, more robust Aperture valve. Based on a check-ball design, the ETU /flight valve design resulted in significantly less surface area to create the seal. Moreover, PVD coatings were eliminated in favor of hardened, nonmagnetic corrosion resistant alloys. Test results were impressive, with the valve achieving five orders of magnitude better sealing leak rate over end of life requirements. Cycle life was equally impressive, achieving 280,000 cycles without failure.

  20. Total prosthetic replacement of atrioventricular valves in the dog

    PubMed Central

    Den Otter, G.

    1968-01-01

    The free-floating cone and cage valve, described in a previous study as being successful as a substitute for the right atrioventricular valve, does not perform well when it is inserted in the mitral ostium. A tilting cone or disc was constructed and tested in a series of 15 dogs. This prosthesis gave excellent results in 12 animals. The reasons for its failure in the remaining three is discussed. The prosthesis presented has advantages over any ball and cage valve, mainly because of its smaller volume. Images PMID:5654076

  1. The inertia ball

    NASA Astrophysics Data System (ADS)

    Bouffard, Karen

    2001-01-01

    We used this activity in the Eastern Massachusetts Physics Olympics and were pleased to find in it an important teaching tool for the concept of circular motion. I now introduce centripetal force in my class with this activity. Using only the "business end" of a broom, team members will push a bowling ball from the starting line along a masking-tape course without going outside the tape or hitting one of the pylons.

  2. Bowling Ball Spotting

    NASA Astrophysics Data System (ADS)

    1985-01-01

    Exactatron, an accurate weighing and spotting system in bowling ball manufacture, was developed by Ebonite International engineers with the assistance of a NASA computer search which identified Jet Propulsion Laboratory (JPL) technology. The JPL research concerned a means of determining the center of an object's mass, and an apparatus for measuring liquid viscosity, enabling Ebonite to identify the exact spotting of the drilling point for top weighting.

  3. Ball Lightning Investigations

    NASA Astrophysics Data System (ADS)

    Bychkov, V. L.; Nikitin, A. I.; Dijkhuis, G. C.

    Ball lightning (BL) researches' review and theoretical models of three different authors are presented. The general review covers investigations from 1838 until the present day, and includes a discussion on observation data, experimental modeling, and theoretical approaches. Section 6.1 is written by Bychkov and Nikitin; authors of the sections 6.2, 6.3 and 6.4 are, respectively, Bychkov, Nikitin and Dijkhuis.

  4. Dump valve

    SciTech Connect

    Webber, J.C.

    1981-06-23

    A swab assembly is provided having a dump valve responsive to fluid pressure and drag which will dump the fluid load should either fluid load or drag or the effect of both fluid load and drag become abnormal. Also if the fluid pressure and/or drag become abnormal, the fluid load on the cup will be released and wash away foreign material causing abnormal drag. When the cup is dumped the pulling capabilities of the wireline truck can concentrate on overcoming the drag. The dump valve opens to wide open position and remains open to dump the fluid to assist in washing away solid materials above the cup. A swab assembly also is provided which with normal drag and an overload, may be pulled relatively slowly, but if pulled too rapidly will result in the load on the swab being dumped to protect the swab assembly and the pulling apparatus from damage. 15 claims.

  5. ELECTROSTRICTION VALVE

    DOEpatents

    Kippenhan, D.O.

    1962-09-25

    An accurately controlled, pulse gas valve is designed capable of delivering output pulses which vary in length from one-tenth millisecond to one second or more, repeated at intervals of a few milliseconds or- more. The pulsed gas valve comprises a column formed of barium titanate discs mounted in stacked relation and electrically connected in parallel, with means for applying voltage across the discs to cause them to expand and effect a mechanical elongation axially of the column. The column is mounted within an enclosure having an inlet port and an outlet port with an internal seat in communication with the outlet port, such that a plug secured to the end of the column will engage the seat of the outlet port to close the outlet port in response to the application of voltage is regulated by a conventional electronic timing circuit connected to the column. (AEC)

  6. Water ball collision

    NASA Technical Reports Server (NTRS)

    Fujimoto, K.

    1986-01-01

    What happens if a stainless steel ball hits a water ball in the weightless space ot the Universe? In other words, it was the objective of our experiments in the Space to observe the surface tension of liquid by means of making a solid collide with a liquid. Place a small volume of water between 2 glass sheets to make a thin water membrane: the 2 glass sheets cannot be separated unless an enormous force is applied. It is obvious from this phenomenom that the surface tension of water is far greater than presumed. On Earth, however, it is impossible in most cases to observe only the surface tension of liquid, because gravity always acts on the surface tension. Water and stainless steel balls were chosen the liquid and solids for the experiments. Because water is the liquid most familiar to us, its properties are well known. And it is also of great interest to compare its properties on the Earth with those in the weightless space.

  7. Fairchild Stratos Division's Type II prototype lockhopper valve: METC Prototype Test Valve No. F-1 prototype lockhopper valve-testing and development project. Static test report

    SciTech Connect

    Goff, D. R.; Cutright, R. L.; Griffith, R. A.; Loomis, R. B.; Maxfield, D. A.; Moritz, R. S.

    1981-10-01

    METC Prototype Test Valve No. F-1 is a hybrid design, based on a segmented ball termed a visor valve, developed and manufactured by Fairchild Stratos Division under contract to the Department of Energy. The valve uses a visor arm that rotates into position and then translates to seal. This valve conditionally completed static testing at METC with clean gas to pressures of 1600 psig and internal valve temperatures to 600/sup 0/F. External leakage was excessive due to leakage through the stuffing box, purge fittings, external bolts, and other assemblies. The stuffing box was repacked several times and redesigned midway through the testing, but external leakage was still excessive. Internal leakage through the seats, except for a few anomalies, was very low throughout the 2409 cycles of testing. As shown by the low internal leakage, the visor valve concept appears to have potential for lock-hopper valve applications. The problems that are present with METC Prototype Test Valve No. F-1 are in the seals, which are equivalent to the shaft and bonnet seals in standard valve designs. The operating conditions at these seals are well within the capabilities of available seal designs and materials. Further engineering and minor modifications should be able to resolve the problems identified during static testing.

  8. Low-Leak, High-Flow Poppet Valve

    NASA Technical Reports Server (NTRS)

    Tervo, John N.

    1995-01-01

    Valve with conical poppet modified to incorporate smooth transition to segment of sphere at upstream end of cone. Constitutes sealing surface of poppet; results in leak rate equivalent to ball-type poppet, and extremely low flow losses. Also enables use of loose fit for guiding poppet, with resulting lower manufacturing cost, high reliability, and long operating life.

  9. Development of Small-sized Fluid Control Valve with Self-holding Function Using Permanent Magnet

    NASA Astrophysics Data System (ADS)

    Akagi, Tetsuya; Dohta, Shujiro; Ueda, Hirofumi

    Recently, force feedback devices in virtual reality and power assisted nursing care systems have received much attention and active research. In such a control system, an actuator and a driving device such as a control valve are mounted on the human body. In this condition, the size and weight of the control valve become serious problems. At the same time, the valve should be operated with lower energy consumption because of using a limited electrical power. The typical electro magnetic solenoid valve drives its spool using a larger solenoid to open the valve. The complex construction of the valve for sealing makes its miniaturization and the fabrication of a low cost valve more difficult. In addition, the solenoid in the valve consumes more electrical power while the valve is kept opening. The purpose of our study is to develop a small-sized, lightweight, lower energy consumption and flexible control valve that can be safe enough to mount on the human body at a lower cost. In our pervious study, we proposed and tested the control valve that can open using a vibration motor. In this study, we propose and test a new type of fluid control valve with a self-holding function. The new valve uses a permanent magnet ball. It has a cylindrical magnet and two solenoids. The self-holding function of the valve is done as follows. When one side of the solenoid is stimulated by the current momentarily, the solenoid gives a repulsive force to the cylindrical magnet. The magnet moves toward the opposite side of the solenoid and is attracted to the iron core. Then, the magnet ball moves toward the cylindrical magnet and opens the orifice. The valve can keep open without electrical energy. As a result, the valve with the extremely lower energy consumption can be developed.

  10. Automatic shutoff valve

    NASA Technical Reports Server (NTRS)

    Hawkins, S. F.; Overbey, C. W.

    1980-01-01

    Cellulose-sponge disk absorbs incoming water and expands with enough force to shut valve. When water recedes, valve opens by squeezing sponge dry to its original size. This direct mechanical action is considered more reliable than solenoid valve.

  11. Automatic shutoff valve

    NASA Technical Reports Server (NTRS)

    Hawkins, S. F.; Overbey, C. W.

    1980-01-01

    Cellulose-sponge disk absorbs incoming water and expands with enough force to shut valve. When water recedes, valve opens by squeezing sponge dry to its original size. This direct mechanical action is considered more reliable than solenoid valve.

  12. Mitral Valve Disease

    MedlinePlus

    ... Tricuspid Valve Disease Cardiac Rhythm Disturbances Thoracic Aortic Aneurysm Pediatric and Congenital Heart Disease Heart abnormalities that are ... Transplantation End-stage Lung Disease Adult Lung Transplantation Pediatric Lung ... Aortic Aneurysm Mitral Valve Disease Overview The mitral valve is ...

  13. Magnetically operated check valve

    NASA Technical Reports Server (NTRS)

    Morris, Brian G. (Inventor); Bozeman, Richard J., Jr. (Inventor)

    1994-01-01

    A magnetically operated check valve is disclosed. The valve is comprised of a valve body and a movable poppet disposed therein. A magnet attracts the poppet to hold the valve shut until the force of fluid flow through the valve overcomes the magnetic attraction and moves the poppet to an unseated, open position. The poppet and magnet are configured and disposed to trap a magnetically attracted particulate and prevent it from flowing to a valve seating region.

  14. Magnetically operated check valve

    NASA Astrophysics Data System (ADS)

    Morris, Brian G.; Bozeman, Richard J., Jr.

    1994-06-01

    A magnetically operated check valve is disclosed. The valve is comprised of a valve body and a movable poppet disposed therein. A magnet attracts the poppet to hold the valve shut until the force of fluid flow through the valve overcomes the magnetic attraction and moves the poppet to an unseated, open position. The poppet and magnet are configured and disposed to trap a magnetically attracted particulate and prevent it from flowing to a valve seating region.

  15. Polyurethane retainers for ball bearings

    NASA Technical Reports Server (NTRS)

    Christy, R. I.

    1973-01-01

    Evaluation of a new ball bearing retainer material is reported. A special composite polyurethane foam ball retainer has been developed that has virtually zero wear, is chemically inert to hydrocarbon lubricants, and stores up to 60 times as much lubricant per unit volume as the most commonly used retainer material, cotton phenolic. This new retainer concept shows promise of years of ball bearing operation without reoiling, based on life testing in high vacuum.

  16. Physics in a Glitter Ball

    ERIC Educational Resources Information Center

    Trikosko, Walter

    2011-01-01

    Maui Toys' Water Bouncer (Fig. 1) is a water-filled ball containing glitter. Buy one and put it on your desk and students can't keep their hands off of it. Pitch the ball in the air giving it a quick spin. When you catch it you will see a sparkling vortex. Twist the ball around different ways and the angular momentum of the fluid keeps the axis of…

  17. Physics in a Glitter Ball

    ERIC Educational Resources Information Center

    Trikosko, Walter

    2011-01-01

    Maui Toys' Water Bouncer (Fig. 1) is a water-filled ball containing glitter. Buy one and put it on your desk and students can't keep their hands off of it. Pitch the ball in the air giving it a quick spin. When you catch it you will see a sparkling vortex. Twist the ball around different ways and the angular momentum of the fluid keeps the axis of…

  18. Fast-Acting Valve

    NASA Technical Reports Server (NTRS)

    Wojciechowski, Bogdan V. (Inventor); Pegg, Robert J. (Inventor)

    2003-01-01

    A fast-acting valve includes an annular valve seat that defines an annular valve orifice between the edges of the annular valve seat, an annular valve plug sized to cover the valve orifice when the valve is closed, and a valve-plug holder for moving the annular valve plug on and off the annular valve seat. The use of an annular orifice reduces the characteristic distance between the edges of the valve seat. Rather than this distance being equal to the diameter of the orifice, as it is for a conventional circular orifice, the characteristic distance equals the distance between the inner and outer radii (for a circular annulus). The reduced characteristic distance greatly reduces the gap required between the annular valve plug and the annular valve seat for the valve to be fully open, thereby greatly reducing the required stroke and corresponding speed and acceleration of the annular valve plug. The use of a valve-plug holder that is under independent control to move the annular valve plug between its open and closed positions is important for achieving controllable fast operation of the valve.

  19. PEPC LRU: Ball Support Assembly

    SciTech Connect

    Alger, T

    1999-05-14

    The PEPC LRU upper ball support assembly consists of a ball and a pneumatic air cylinder/conical seat latching mechanism to be attached to the optics support frame,and a ball attached to the PEPC LRU. Both components are designed to allow manual positioning in three axes. Upon insertion of the PEPC LRU into the structure, the upper pneumatic cylinder is actuated to latch the two assemblies together through the conical seat device to grab the lower ball to support the LRU weight. To be conservative, the design load for the assembly is 1500 pounds (the prototype PEPC LRU weight was measured to be near 1380 pounds).

  20. Individual ball possession in soccer

    PubMed Central

    Hoernig, Martin

    2017-01-01

    This paper describes models for detecting individual and team ball possession in soccer based on position data. The types of ball possession are classified as Individual Ball Possession (IBC), Individual Ball Action (IBA), Individual Ball Control (IBC), Team Ball Possession (TBP), Team Ball Control (TBC) und Team Playmaking (TPM) according to different starting points and endpoints and the type of ball control involved. The machine learning approach used is able to determine how long the ball spends in the sphere of influence of a player based on the distance between the players and the ball together with their direction of motion, speed and the acceleration of the ball. The degree of ball control exhibited during this phase is classified based on the spatio-temporal configuration of the player controlling the ball, the ball itself and opposing players using a Bayesian network. The evaluation and application of this approach uses data from 60 matches in the German Bundesliga season of 2013/14, including 69,667 IBA intervals. The identification rate was F = .88 for IBA and F = .83 for IBP, and the classification rate for IBC was κ = .67. Match analysis showed the following mean values per match: TBP 56:04 ± 5:12 min, TPM 50:01 ± 7:05 min and TBC 17:49 ± 8:13 min. There were 836 ± 424 IBC intervals per match and their number was significantly reduced by -5.1% from the 1st to 2nd half. The analysis of ball possession at the player level indicates shortest accumulated IBC times for the central forwards (0:49 ± 0:43 min) and the longest for goalkeepers (1:38 ± 0:58 min), central defenders (1:38 ± 1:09 min) and central midfielders (1:27 ± 1:08 min). The results could improve performance analysis in soccer, help to detect match events automatically, and allow discernment of higher value tactical structures, which is based on individual ball possession. PMID:28692649

  1. Individual ball possession in soccer.

    PubMed

    Link, Daniel; Hoernig, Martin

    2017-01-01

    This paper describes models for detecting individual and team ball possession in soccer based on position data. The types of ball possession are classified as Individual Ball Possession (IBC), Individual Ball Action (IBA), Individual Ball Control (IBC), Team Ball Possession (TBP), Team Ball Control (TBC) und Team Playmaking (TPM) according to different starting points and endpoints and the type of ball control involved. The machine learning approach used is able to determine how long the ball spends in the sphere of influence of a player based on the distance between the players and the ball together with their direction of motion, speed and the acceleration of the ball. The degree of ball control exhibited during this phase is classified based on the spatio-temporal configuration of the player controlling the ball, the ball itself and opposing players using a Bayesian network. The evaluation and application of this approach uses data from 60 matches in the German Bundesliga season of 2013/14, including 69,667 IBA intervals. The identification rate was F = .88 for IBA and F = .83 for IBP, and the classification rate for IBC was κ = .67. Match analysis showed the following mean values per match: TBP 56:04 ± 5:12 min, TPM 50:01 ± 7:05 min and TBC 17:49 ± 8:13 min. There were 836 ± 424 IBC intervals per match and their number was significantly reduced by -5.1% from the 1st to 2nd half. The analysis of ball possession at the player level indicates shortest accumulated IBC times for the central forwards (0:49 ± 0:43 min) and the longest for goalkeepers (1:38 ± 0:58 min), central defenders (1:38 ± 1:09 min) and central midfielders (1:27 ± 1:08 min). The results could improve performance analysis in soccer, help to detect match events automatically, and allow discernment of higher value tactical structures, which is based on individual ball possession.

  2. Preliminary characterization of active MEMS valves.

    SciTech Connect

    Barnard, Casey Anderson

    2010-08-01

    Partial characterization of a series of electrostatically actuated active microfluidic valves is to be performed. Tests are performed on a series of 24 valves from two different MEMS sets. Focus is on the physical deformation of the structures under variable pressure loadings, as well as voltage levels. Other issues that inhibit proper performance of the valves are observed, addressed and documented as well. Many microfluidic applications have need for the distribution of gases at finely specified pressures and times. To this end a series of electrostatically actuated active valves have been fabricated. Eight separate silicon die are discussed, each with a series of four active valves present. The devices are designed such that the valve boss is held at a ground, with a voltage applied to lower contacts. Resulting electrostatic forces pull the boss down against a series of stops, intended to create a seal as well as prevent accidental shorting of the device. They have been uniquely packaged atop a stack of material layers, which have inlaid channels for application of fluid flow to the backside of the valve. Electrical contact is supplied from the underlying printed circuit board, attached to external supplies and along traces on the silicon. Pressure is supplied from a reservoir of house compressed air, up to 100 Psig. This is routed through a Norgren R07-200-RGKA pressure regulator, rated to 150 Psig. From there flow passes a manually operated ball valve, and to a flow meter. Two flow meters were utilized; initially an Omega FMA1802 rated at 10 sccm, and followed by a Flocat model for higher flow rates up to 100 sccm. An Omega DPG4000-500 pressure gauge produced pressure measurements. Optical measurements were returned via a WYKO Interferometry probe station. This would allow for determination of physical deformations of the device under a variety of voltage and pressure loads. This knowledge could lead to insight as to the failure mechanisms of the device

  3. Actuation and system design and evaluation OMS engine shutoff valve, Volume 1. [space shuttles

    NASA Technical Reports Server (NTRS)

    Dunn, V. B.

    1975-01-01

    A technology program was conducted to identify and verify the optimum valve and actuation system concept for the Space Shuttle Orbit Maneuvering System engine. Of major importance to the valve and actuation system selection was the ten-year, 100-mission, 10,000-cycle life requirement, while maintaining high reliability, low leakage, and low weight. Valve and actuation system concepts were comparatively evaluated against past valve failure reports and potential failure modes due to the shuttle mission profile to aid in the selection of the most optimum concept for design, manufacture and verification testing. Two valve concepts were considered during the preliminary design stage; i.e., the moving seat and lifting ball. Two actuation systems were manufactured and tested. Test results demonstrate the viability of a lifting ball concept as well as the applicability of an ac motor actuation system to best meet the requirements of the shuttle mission.

  4. The "Policy Cycle": A Ball by Ball Account.

    ERIC Educational Resources Information Center

    Hatcher, Richard; Troyna, Barry

    1994-01-01

    Concerned with Stephen Ball's theoretical and empirical contribution to contemporary "education policy sociology," this article examines the efficacy of his theoretical eclecticism, highlighting incompatibilities in his interpretation and application of certain social and political theorists. Ball's representation of the policy cycle, as…

  5. Crystal Ball Replica

    NASA Astrophysics Data System (ADS)

    Ajamian, John

    2016-09-01

    The A2 collaboration of the Institute for Nuclear Physics of Johannes Gutenberg University performs research on (multiple) meson photoproduction and nucleon structure and dynamics using a high energy polarized photon beam at specific targets. Particles scattered from the target are detected in the Crystal Ball, or CB. The CB is composed of 672 NaI crystals that surround the target and can analyze particle type and energy of ejected particles. Our project was to create a replica of the CB that could display what was happening in real time on a 3 Dimensional scale replica. Our replica was constructed to help explain the physics to the general public, be used as a tool when calibrating each of the 672 NaI crystals, and to better analyze the electron showering of particles coming from the target. This poster will focus on the hardware steps necessary to construct the replica and wire the 672 programmable LEDS in such a way that they can be mapped to correspond to the Crystal Ball elements. George Washington NSF Grant.

  6. Crystal Ball Functional Model

    NASA Astrophysics Data System (ADS)

    Plotnick, David

    2016-09-01

    The A2 collaboration of the MAinz MIkrotron is dedicated to studying meson production and nucleon structure and behavior via photon scattering. The photons are made via bremsstrahlung process and energy-tagged using the Glasgow Photon tagger. The photon beam then interacts in a variety of targets: cryogenic, polarized or solid state, and scattered particles deposit their energy within the NaI crystals. Scintillators are able to give results on particles energy and time. Events are reconstructed by combining information from the Tagging spectrometer, the Crystal Ball detector, the TAPS forward wall spectrometer, a Cherenkov detector, and multi-wire proportional chambers. To better understand the detector and experimental events, a live display was built to show energies deposited in crystals in real-time. In order to show a range of energies and particles, addressable LEDs that are individually programmable were used. To best replicate the Crystal Ball, 3D printing technology was employed to build a similar highly segmented icosahedron that can hold each LED, creating a 3D representation of what photons see during experiments. The LEDs were controlled via Arduino microcontroller. Finally, we implemented the Experimental Physics and Industrial Control System to grab live event data, and a simple program converts this data in to color and crystal number data that is able to communicate with the Arduino. Using these simple parts, we can better visualize and understand the tools used in nuclear physics. This material is based upon work supported by the National Science Foundation Grant No. IIA-1358175.

  7. Atmospheric Ball Plasma Interactions

    NASA Astrophysics Data System (ADS)

    Wurden, C. J. V.; Wurden, G. A.

    2008-11-01

    Free-floating atmospheric pressure copper hydroxyl ball plasmas have been studied in air and helium atmospheres, using still and high speed photography (up to 20,000 fps), collimated photodiodes, and spectroscopy. A fine boundary layer between the greenish Cu-OH cloud, and the air, is orange in color. However, when the discharge is initiated into a helium atmosphere, the boundary layer is no longer visible, suggesting that the visible boundary was caused by interactions with oxygen. We have studied scaling of the 10-cm diameter ball plasmas with both the size of the water bucket, and the applied discharge voltage, over the range of 500-5000 volts. When looking at the initial spider-leg breakdown above the water surface, the ratio of H-alpha to H-beta lines suggests a temperature of ˜0.3 eV. This is also consistent with the presence of molecular lines of OH, and perhaps CuOH2 in the rising cloud. The cloud is affected by, but can penetrate through an aluminum window screen mesh.

  8. Reflections on a Bouncing Ball

    ERIC Educational Resources Information Center

    Rohr, Jim; Lopez, Veronica; Rohr, Tyler

    2014-01-01

    While observing the bounce heights of various kinds of sports balls dropped from different heights onto a variety of surfaces, we thought of the following question: Could measurements of drop and bounce heights of balls of different diameters, but of the same material, falling from different heights, but on the same surface, be expressed by a…

  9. Reflections on a Bouncing Ball

    ERIC Educational Resources Information Center

    Rohr, Jim; Lopez, Veronica; Rohr, Tyler

    2014-01-01

    While observing the bounce heights of various kinds of sports balls dropped from different heights onto a variety of surfaces, we thought of the following question: Could measurements of drop and bounce heights of balls of different diameters, but of the same material, falling from different heights, but on the same surface, be expressed by a…

  10. Behaviour of a Bouncing Ball

    ERIC Educational Resources Information Center

    Cross, Rod

    2015-01-01

    The bounce of a ball is a seemingly innocuous event that can be used to illustrate many aspects of elementary and even advanced mechanics. Both normal and oblique bounces on a rigid surface are considered in this article, emphasizing qualitative features of the bounce process. If the ball bounces at an oblique angle then it can slide throughout…

  11. Behaviour of a Bouncing Ball

    ERIC Educational Resources Information Center

    Cross, Rod

    2015-01-01

    The bounce of a ball is a seemingly innocuous event that can be used to illustrate many aspects of elementary and even advanced mechanics. Both normal and oblique bounces on a rigid surface are considered in this article, emphasizing qualitative features of the bounce process. If the ball bounces at an oblique angle then it can slide throughout…

  12. Corrosion-Resistant Ball Bearings

    NASA Technical Reports Server (NTRS)

    Zdankiewicz, E. M.; Linaburg, E. L.; Lytle, L. J.

    1990-01-01

    Self-lubricating bearing system withstands highly corrosive environment of wastewater-recycling unit. New bearings contain cobalt-based-alloy balls and races, graphite/polyimide polymer ball cages, and single integral polytetrafluoroethylene seals on wet sides. Materials and design prevent corrosion by acids and provide lubrication.

  13. Microfluidic sieve valves

    DOEpatents

    Quake, Stephen R; Marcus, Joshua S; Hansen, Carl L

    2015-01-13

    Sieve valves for use in microfluidic device are provided. The valves are useful for impeding the flow of particles, such as chromatography beads or cells, in a microfluidic channel while allowing liquid solution to pass through the valve. The valves find particular use in making microfluidic chromatography modules.

  14. Remote actuated valve implant

    DOEpatents

    McKnight, Timothy E; Johnson, Anthony; Moise, Jr., Kenneth J; Ericson, Milton Nance; Baba, Justin S; Wilgen, John B; Evans, III, Boyd McCutchen

    2014-02-25

    Valve implant systems positionable within a flow passage, the systems having an inlet, an outlet, and a remotely activatable valve between the inlet and outlet, with the valves being operable to provide intermittent occlusion of the flow path. A remote field is applied to provide thermal or magnetic activation of the valves.

  15. Remote actuated valve implant

    DOEpatents

    McKnight, Timothy E.; Johnson, Anthony; Moise, Kenneth J.; Ericson, Milton Nance; Baba, Justin S.; Wilgen, John B.; Evans, Boyd Mccutchen

    2016-05-10

    Valve implant systems positionable within a flow passage, the systems having an inlet, an outlet, and a remotely activatable valve between the inlet and outlet, with the valves being operable to provide intermittent occlusion of the flow path. A remote field is applied to provide thermal or magnetic activation of the valves.

  16. Rotary pneumatic valve

    DOEpatents

    Hardee, Harry C.

    1991-01-01

    A rotary pneumatic valve which is thrust balanced and the pneumatic pressure developed produces only radial loads on the valve cylinder producing negligible resistance and thus minimal torque on the bearings of the valve. The valve is multiplexed such that at least two complete switching cycles occur for each revolution of the cylinder spindle.

  17. Liquid rocket valve components

    NASA Technical Reports Server (NTRS)

    1973-01-01

    A monograph on valves for use with liquid rocket propellant engines is presented. The configurations of the various types of valves are described and illustrated. Design criteria and recommended practices for the various valves are explained. Tables of data are included to show the chief features of valve components in use on operational vehicles.

  18. What makes bowling balls hook?

    NASA Astrophysics Data System (ADS)

    Frohlich, Cliff

    2004-09-01

    This article presents exact equations of motion for a rotating bowling ball in a form that explicitly separates contributions due to nonequal principal moments of inertia, center-of-mass offset, and friction between the ball and lane. A computer program that solves the equations demonstrates that all of these factors are important for a realistic analysis of bowling. These factors significantly affect how much balls hook, that is, deflect sideways and approach the pins at an oblique angle. Simulations that approximate real bowling conditions indicate that the largest contribution comes from variable friction along the lane, that is, bowling lanes are generally prepared so that lane friction is higher by a factor of 2 or more along the last one-third of the ball's trajectory. The analysis supports most (but not all) of the guidelines that bowlers have developed for predicting ball performance.

  19. Reflections on a Bouncing Ball

    NASA Astrophysics Data System (ADS)

    Rohr, Jim; Lopez, Veronica; Rohr, Tyler

    2014-12-01

    While observing the bounce heights of various kinds of sports balls dropped from different heights onto a variety of surfaces, we thought of the following question: Could measurements of drop and bounce heights of balls of different diameters, but of the same material, falling from different heights, but on the same surface, be expressed by a simple mathematical formula? Our objective was to provide a simple classroom ball-drop experiment that produced robust and interesting data sets from which students could address this question. With a suitable choice of variables, all the ball drop data could be collapsed to a single curve, so that given the mass and drop height of the ball, the bounce height could be reasonably estimated (±10% of measured values).

  20. Double valve Implantation

    PubMed Central

    Stassano, Paolo; Mannacio, Vito; Musumeci, Antonino; Golino, Alessandro; Maida, Piero; Ferrigno, Vincenzo; Buonocore, Gaetano; Spampinato, Nicola

    1991-01-01

    From January 1976 through December 1987, 194 patients with a mean age of 43.3 ± 13.7 years (range, 11 to 74 years) underwent double (mitral and aortic) replacement of native valves with 8 types of bioprostheses: Carpentier-Edwards, 127 valves; Hancock, 76 valves; Liotta-Bioimplant, 57 valves; Ionescu-Shiley, 53 valves; Vascor, 27 valves; Carpentier-Edwards Pericardial, 22 valves; Angell-Shiley, 20 valves; and Implamedic, 6 valves. Concomitant cardiac procedures were performed in 25 patients (12.8%). There were 18 operative deaths (9.27%). Our retrospective analysis was restricted to 352 bioprostheses implanted in the 176 patients who survived surgery and were considered at risk for valve tissue failure. The overall cumulative duration of follow-up was 1,174.1 patient-years (range, 1 to 13 years). The durations of follow-up for specific valves were: Carpentier-Edwards, 920.2 valve-years; Hancock, 383.8 valve-years; Liotta-Bioimplant, 310.2 valve-years; Ionescu-Shiley, 357.7 valve-years; Vascor, 131.2 valve-years; Carpentier-Edwards Pericardial, 52.0 valve-years; Angell-Shiley, 167.0 valve-years; and Implamedic, 31.0 valve-years. Thirty patients had thromboembolic accidents, for a linearized incidence of 2.5% per patient-year. At 13 years, the actuarial freedom from thromboembolic accidents was 85.8% ± 10.7%. Nine patients had endocarditis, for a linearized incidence of 0.7% per patient-year. At 13 years, the actuarial freedom from endocarditis was 92.0% ± 1.5%. Twenty-four patients had valve tissue failure, for a cumulative linearized incidence of 1.87% per valve-year. The cumulative actuarial probability of freedom from valve tissue failure was 78.6% ± 3.7% at 10 years and 51.2% ± 10.7% at 13 years. The 24 patients with valve tissue failure all underwent reoperation: 20 of these had double valve replacement, 3 had aortic valve replacement alone, and 1 had mitral valve replacement alone. The mean interval between initial valve implantation and reoperation was

  1. Dual stage check valve

    NASA Technical Reports Server (NTRS)

    Whitten, D. E. (Inventor)

    1973-01-01

    A dual stage seat valve head arrangement is described which consists of a primary sealing point located between a fixed orifice seat and a valve poppet, and a secondary sealing point between an orifice poppet and a valve poppet. Upstream of the valve orifice is a flexible, convoluted metal diaphragm attached to the orifice poppet. Downstream of the valve orifice, a finger spring exerts a force against the valve poppet, tending to keep the valve in a closed position. The series arrangement of a double seat and poppet is able to tolerate small particle contamination while minimizing chatter by controlling throttling or metering across the secondary seat, thus preserving the primary sealing surface.

  2. Throttle valve control device

    SciTech Connect

    Nishida, M.; Katashiba, H.

    1988-03-01

    This patent describes a valve control device which comprises: a valve shaft for operating a throttle valve; a differential gear device having first and second drive gears, for driving the valve shaft; first and second electronic control actuators for rotating the first and second drive gear, respectively; and a sensor for detecting the degree of opening of the throttle valve, so that the operation of the throttle valve is controlled by the electronic control actuators while the degree of opening of the throttle valve is being detected.

  3. Means for positively seating a piezoceramic element in a piezoelectric valve during inlet gas injection

    DOEpatents

    Wright, Kenneth E.

    1994-01-01

    A piezoelectric valve in a gas delivery system includes a piezoceramic element bonded to a valve seal and disposed over a valve seat, and retained in position by an O-ring and a retainer; an insulating ball normally biased by a preload spring against the piezoceramic element; an inlet gas port positioned such that upon admission of inlet gas into the valve, the piezoceramic element is positively seated. The inlet gas port is located only on the side of the piezoceramic element opposite the seal.

  4. Means for positively seating a piezoceramic element in a piezoelectric valve during inlet gas injection

    DOEpatents

    Wright, K.E.

    1994-08-23

    A piezoelectric valve in a gas delivery system includes a piezoceramic element bonded to a valve seal and disposed over a valve seat, and retained in position by an O-ring and a retainer; an insulating ball normally biased by a preload spring against the piezoceramic element; an inlet gas port positioned such that upon admission of inlet gas into the valve, the piezoceramic element is positively seated. The inlet gas port is located only on the side of the piezoceramic element opposite the seal. 3 figs.

  5. Bellows sealed plug valve

    DOEpatents

    Dukas, Jr., Stephen J.

    1990-01-01

    A bellows sealed plug valve includes a valve body having an inlet passage and an outlet passage, a valve chamber between the inlet and outlet passages. A valve plug has substantially the same shape as the valve chamber and is rotatably disposed therein. A shaft is movable linearly in response to a signal from a valve actuator. A bellows is sealingly disposed between the valve chamber and the valve actuator and means are located between the bellows and the valve plug for converting linear movement of the shaft connected to the valve actuator to rotational movement of the plug. Various means are disclosed including helical thread mechanism, clevis mechanism and rack and pinion mechanism, all for converting linear motion to rotational motion.

  6. Vacuum breaker valve assembly

    DOEpatents

    Thompson, Jeffrey L.; Upton, Hubert Allen

    1999-04-27

    Breaker valve assemblies for a simplified boiling water nuclear reactor are described. The breaker valve assembly, in one form, includes a valve body and a breaker valve. The valve body includes an interior chamber, and an inlet passage extends from the chamber and through an inlet opening to facilitate transporting particles from outside of the valve body to the interior chamber. The breaker valve is positioned in the chamber and is configured to substantially seal the inlet opening. Particularly, the breaker valve includes a disk which is sized to cover the inlet opening. The disk is movably coupled to the valve body and is configured to move substantially concentrically with respect to the valve opening between a first position, where the disk completely covers the inlet opening, and a second position, where the disk does not completely cover the inlet opening.

  7. Scissor thrust valve actuator

    DOEpatents

    DeWall, Kevin G.; Watkins, John C; Nitzel, Michael E.

    2006-08-29

    Apparatus for actuating a valve includes a support frame and at least one valve driving linkage arm, one end of which is rotatably connected to a valve stem of the valve and the other end of which is rotatably connected to a screw block. A motor connected to the frame is operatively connected to a motor driven shaft which is in threaded screw driving relationship with the screw block. The motor rotates the motor driven shaft which drives translational movement of the screw block which drives rotatable movement of the valve driving linkage arm which drives translational movement of the valve stem. The valve actuator may further include a sensory control element disposed in operative relationship with the valve stem, the sensory control element being adapted to provide control over the position of the valve stem by at least sensing the travel and/or position of the valve stem.

  8. Valve-in-Valve Replacement Using a Sutureless Aortic Valve

    PubMed Central

    Dohmen, Pascal M.; Lehmkuhl, Lukas; Borger, Michael A.; Misfeld, Martin; Mohr, Friedrich W.

    2016-01-01

    Patient: Female, 61 Final Diagnosis: Tissue degeneration Symptoms: Dyspnea Medication: — Clinical Procedure: Redo valve replacement Specialty: Surgery Objective: Rare disease Background: We present a unique case of a 61-year-old female patient with homograft deterioration after redo surgery for prosthetic valve endocarditis with root abscess. Case Report: The first operation was performed for type A dissection with root, arch, and elephant trunk replacement of the thoracic aorta. The present re-redo surgery was performed as valve-in-valve with a sutureless aortic biopros-thesis. The postoperative course was uneventful and the patient was discharged on day 6. Conclusions: The current case report demonstrates that sutureless bioprostheses are an attractive option for surgical valve-in-valve procedures, which can reduce morbidity and mortality. PMID:27694795

  9. Rotary Valve FY 2016 Highlights

    SciTech Connect

    Fitsos, P.

    2016-12-07

    The fiscal year started with the Rotary Valve (RV) being reassembled after having crashed in June of 2015. The crash occurred when the RV inner surface contacted the housing. The cause of the crash was never confirmed. No particles were found in the 2.5 thousandths of an inch gap and the filters the helium gas passed through were all clean. There were marks on the bearings that looked like electrostatic discharge as shown below in Figure 1. These marks hadn’t been seen before and there were similar discharge marks on some of the ball bearings. Examples of this were found in a literature search of bearing failures. This leads to a possible cause due to this arcing affecting the rotational accuracy of the bearings driving the RV into the housing.

  10. Heart valve surgery - series (image)

    MedlinePlus

    There are four valves in the heart: aortic valve, mitral valve, tricuspid valve, and pulmonary valve. The valves are designed to control the direction of blood flow through the heart. The opening and closing of the heart valves produce the heart-beat sounds.

  11. The ISOLDE Silicon Ball

    SciTech Connect

    Fraile, L.M.

    2003-09-16

    The investigation of weakly bound nuclei close to the particle driplines makes necessary the development of new spectroscopy devices with the capability of detecting charged particles and precisely determining their energy, angular distribution and nature. With this aim the ISOLDE Silicon Ball is under construction. It is a charged particle spectroscopy device with the requirements of high geometrical efficiency and broad energy range coverage, designed for the investigation of the exotic nuclei produced at ISOLDE and at other similar facilities. In order to allow for particle identification the simultaneous use of the Time of Flight (TOF) and Pulse Shape Discrimination (PSD) techniques is intended. Recoil tagging capabilities, suitable for transfer reactions to be performed at REX-ISOLDE, should be foreseen for a future development. The design and realization of the first prototype, together with the first tests are reported.

  12. Valve for fluid control

    DOEpatents

    Oborny, Michael C.; Paul, Phillip H.; Hencken, Kenneth R.; Frye-Mason, Gregory C.; Manginell, Ronald P.

    2001-01-01

    A valve for controlling fluid flows. This valve, which includes both an actuation device and a valve body provides: the ability to incorporate both the actuation device and valve into a unitary structure that can be placed onto a microchip, the ability to generate higher actuation pressures and thus control higher fluid pressures than conventional microvalves, and a device that draws only microwatts of power. An electrokinetic pump that converts electric potential to hydraulic force is used to operate, or actuate, the valve.

  13. Magnetically operated check valve

    NASA Astrophysics Data System (ADS)

    Morris, Brian G.; Bozeman, Richard J., Jr.

    1993-03-01

    A magnetically operated check valve is disclosed having, in one aspect, a valve body and a movable poppet disposed therein. A magnet attracts the poppet to hold the valve shut until the force of fluid flow through the valve overcomes the magnetic attraction and moves the poppet to an unseated, open position. The poppet and magnet are configured and disposed to trap a magnetically attracted particulate and prevent it from flowing to a valve seating region.

  14. Conformal Contact Problems of Ball-socket and Ball

    NASA Astrophysics Data System (ADS)

    Sun, Zhangang; Hao, Caizhe

    This paper focuses attention on non-conformal and almost conformal contact of ball and ball-socket. Two-dimensional finite element models are developed to calculate the normal contact stress distribution and contact area. The effects of geometry dimension and external load on the contact pressure distribution and contact region are presented, respectively. Meanwhile, the results of FEM and solutions of Hertz contact theory are compared. The results indicates that contact state of ball and ball-socket changes from point contact to area contact with the increasing of the dimensionless number-curvature radius coefficient f and the number of f =0.536 (≈0.54) is critical parameter causing the change.

  15. The coefficient of restitution for collisions of happy balls, unhappy balls, and tennis balls

    NASA Astrophysics Data System (ADS)

    Cross, Rod

    2000-11-01

    A perfectly happy ball is one that bounces to its original height when dropped on a massive, rigid surface. A completely unhappy ball does not bounce at all. In the former case, the coefficient of restitution (COR) is unity. In the latter case, the COR is zero. It is shown that when an unhappy ball collides with a happy ball, the COR increases from zero to unity as the stiffness of the happy ball decreases from infinity to zero. The COR is independent of the mass of each ball. The implication of reducing the COR of a tennis ball, as a possible means of slowing the serve in tennis, is also considered. It is shown that (a) the COR for a collision with a racket varies with the impact point and is a maximum at the vibration node near the center of the strings, and (b) the serve speed is reduced by only about 20% if the COR for a bounce on the court is reduced to zero.

  16. Enhancing the Bounce of a Ball

    ERIC Educational Resources Information Center

    Cross, Rod

    2010-01-01

    In sports such as baseball, softball, golf, and tennis, a common objective is to hit the ball as fast or as far as possible. Another common objective is to hit the ball so that it spins as fast as possible, since the trajectory of the ball through the air is strongly affected by ball spin. In an attempt to enhance both the coefficient of…

  17. Enhancing the Bounce of a Ball

    ERIC Educational Resources Information Center

    Cross, Rod

    2010-01-01

    In sports such as baseball, softball, golf, and tennis, a common objective is to hit the ball as fast or as far as possible. Another common objective is to hit the ball so that it spins as fast as possible, since the trajectory of the ball through the air is strongly affected by ball spin. In an attempt to enhance both the coefficient of…

  18. Quickly Removable Valve

    NASA Technical Reports Server (NTRS)

    Robbins, John S.

    1988-01-01

    Unit removed with minimal disturbance. Valve inlet and outlet ports adjacent to each other on same side of valve body. Ports inserted into special manifold on fluid line. Valve body attached to manifold by four bolts or, alternatively, by toggle clamps. Electromechanical actuator moves in direction parallel to fluid line to open and close valve. When necessary to clean valve, removed simply by opening bolts or toggle clamps. No need to move or separate ports of fluid line. Valve useful where disturbance of fluid line detrimental or where fast maintenance essential - in oil and chemical industries, automotive vehicles, aircraft, and powerplants.

  19. Quickly Removable Valve

    NASA Technical Reports Server (NTRS)

    Robbins, John S.

    1988-01-01

    Unit removed with minimal disturbance. Valve inlet and outlet ports adjacent to each other on same side of valve body. Ports inserted into special manifold on fluid line. Valve body attached to manifold by four bolts or, alternatively, by toggle clamps. Electromechanical actuator moves in direction parallel to fluid line to open and close valve. When necessary to clean valve, removed simply by opening bolts or toggle clamps. No need to move or separate ports of fluid line. Valve useful where disturbance of fluid line detrimental or where fast maintenance essential - in oil and chemical industries, automotive vehicles, aircraft, and powerplants.

  20. Fast acting check valve

    NASA Technical Reports Server (NTRS)

    Perkins, Gerald S. (Inventor)

    1979-01-01

    A check valve which closes more rapidly to prevent wearing of the valve seat and of the valve member that seals thereagainst, including a solenoid or other actuator that aids the normal spring to quickly close the valve at approximately the time when downpath fluid flow would stop, the actuator then being deenergized. The control circuit that operates the actuator can include a pair of pressure sensors sensing pressure both upstream and downstream from the valve seat. Where the valve is utilized to control flow to or from a piston pump, energization of the actuator can be controlled by sensing when the pump piston reaches its extreme of travel.

  1. Transcatheter aortic valve implantation.

    PubMed

    Oliemy, Ahmed; Al-Attar, Nawwar

    2014-01-01

    Transcatheter aortic valve implantation was developed to offer a therapeutic solution to patients with severe symptomatic aortic stenosis who are not candidates for conventional aortic valve replacement. The improvement in transcatheter aortic valve implantation outcomes is still of concern in the areas of stroke, vascular injury, heart block, paravalvular regurgitation and valve durability. Concomitantly, the progress, both technical and in terms of material advances of transcatheter valve systems, as well as in patient selection, renders transcatheter aortic valve implantation an increasingly viable treatment for more and more patients with structural heart disease.

  2. History of ball bearings

    NASA Technical Reports Server (NTRS)

    Dowson, D.; Hamrock, B. J.

    1981-01-01

    The familiar precision rolling-element bearings of the twentieth century are products of exacting technology and sophisticated science. Their very effectiveness and basic simplicity of form may discourage further interest in their history and development. Yet the full story covers a large portion of recorded history and surprising evidence of an early recognition of the advantages of rolling motion over sliding action and progress toward the development of rolling-element bearings. The development of rolling-element bearings is followed from the earliest civilizations to the end of the eighteenth century. The influence of general technological developments, particularly those concerned with the movement of large building blocks, road transportation, instruments, water-raising equipment, and windmills are discussed, together with the emergence of studies of the nature of rolling friction and the impact of economic factors. By 1800 the essential features of ball and rolling-element bearings had emerged and it only remained for precision manufacture and mass production to confirm the value of these fascinating machine elements.

  3. Ball-joint grounding ring

    NASA Technical Reports Server (NTRS)

    Aperlo, P. J. A.; Buck, P. A.; Weldon, V. A.

    1981-01-01

    In ball and socket joint where electrical insulator such as polytetrafluoroethylene is used as line to minimize friction, good electrical contact across joint may be needed for lightning protection or to prevent static-charge build-up. Electrical contact is maintained by ring of spring-loaded fingers mounted in socket. It may be useful in industry for cranes, trailers, and other applications requiring ball and socket joint.

  4. MODIFIED BALL AND SOCKET COUPLING

    DOEpatents

    Kalen, D.D.

    1961-05-23

    A ball and socket coupling arrangement is described in which the male and female members may be engaged or disengaged without visual aid. The female member has an internal spherical seat through which slots are provided to accommodate appropriately arranged and shaped ribs in the ball member. After engagement of the members, one or both are rotated to lock them together to prevent accidental disengagement. (AEC)

  5. Modified Ball and Socket Coupling

    DOEpatents

    Conley, Jr, W. R.; Pitman, R. W.

    1961-05-23

    A ball and socket coupling arrangement is given in which the male and female members may be engaged or disengaged without visual aid. The female member has an internal spherical seat through which slots are provided to accommodate appropriately arranged and shaped ribs in the male ball member. After engagement of the members, one or both are rotated to lock them together to prevent accidental disengagement.

  6. Pump, and earth-testable spacecraft capillary heat transport loop using augmentation pump and check valves

    NASA Technical Reports Server (NTRS)

    Baker, David (Inventor)

    1998-01-01

    A spacecraft includes heat-generating payload equipment, and a heat transport system with a cold plate thermally coupled to the equipment and a capillary-wick evaporator, for evaporating coolant liquid to cool the equipment. The coolant vapor is coupled to a condenser and in a loop back to the evaporator. A heated coolant reservoir is coupled to the loop for pressure control. If the wick is not wetted, heat transfer will not begin or continue. A pair of check valves are coupled in the loop, and the heater is cycled for augmentation pumping of coolant to and from the reservoir. This augmentation pumping, in conjunction with the check valves, wets the wick. The wick liquid storage capacity allows the augmentation pump to provide continuous pulsed liquid flow to assure continuous vapor transport and a continuously operating heat transport system. The check valves are of the ball type to assure maximum reliability. However, any type of check valve can be used, including designs which are preloaded in the closed position. The check valve may use any ball or poppet material which resists corrosion. For optimum performance during testing on Earth, the ball or poppet would have neutral buoyancy or be configured in a closed position when the heat transport system is not operating. The ball may be porous to allow passage of coolant vapor.

  7. Valve mechanism having variable valve timing

    SciTech Connect

    Oda, H.; Masuda, S.; Morita, Y.

    1986-04-08

    This patent describes a valve mechanism for an internal combustion engine which consists of a camshaft rotatable about a longitudinal axis and having a cam formed thereon, a swingable member mounted for swinging movement about the longitudinal axis of the camshaft and formed with a tappet receiving hole. A valve tapper is received in the tappet receiving hole for a slidable movement along the tappet receiving hole. The tappet has a cam which engages the surface at one end and a stem engages the surface at the other end. A valve stem is mounted for axial movement and engaged at one end with the stem engaging, surface of the tappet to be actuated thereby. A valve timing control swingably moves the swingable member and the tappet about the camshaft axis in accordance with predetermined engine operating conditions to thereby change valve opening and valve closing timing. The control includes means for holding the swingable member at a first position. The tappet and valve stem are in contact at a first position on the stem engaging surface of the tappet and the direction of the slidable movement of the tappet is aligned with the direction of the axial movement of the valve stem at least under heavy load, high speed engine operation, and for moving the swingable member from the first position to a second position. The tappet and valve stem are in contact at a second position on the stem engaging surface of the tappet at low speed engine operation to effect a change in valve opening and valve closing timing.

  8. Pump isolation valve

    DOEpatents

    Kinney, Calvin L.; Wetherill, Todd M.

    1983-08-02

    The pump isolation valve provides a means by which the pump may be selectively isolated from the remainder of the coolant system while being compatible with the internal hydraulic arrangement of the pump during normal operation of the pump. The valve comprises a valve cylinder disposed around the pump and adjacent to the last pump diffuser with a turning vane attached to the lower end of the valve cylinder in a manner so as to hydraulically match with the discharge diffuser. The valve cylinder is connected to a drive means for sliding the valve cylinder relative to the diffuser support cylinder so as to block flow in either direction through the discharge diffuser when the valve is in the closed position and to aid in the flow of the coolant from the discharge diffuser by means of the turning vane when the valve is in the open position.

  9. Mud separator valve apparatus

    SciTech Connect

    Schneider, S.J.

    1981-12-08

    An automatic cleaning system is provided for a mud separator apparatus. Water and mud inputs to a mud pump feeding the separator are respectively controlled by two butterfly valves ganged for cooperation, and operated by a single valve actuator motor. When the mud separator is shut off, a time delay relay is actuated which keeps the mud separator rotor motor on line during a predetermined flush cycle. The valve actuator opens the water valve, and closes the mud valve, permitting the separator to be flushed with water. Activating the start button returns the valve actuator to the position in which the mud valve is open and the water valve is closed, thereby returning the apparatus to the mud separation cycle.

  10. Valve Health Monitor (VHM)

    NASA Technical Reports Server (NTRS)

    Perotti, Jose M.; Delgado, H. (Technical Monitor)

    2002-01-01

    This presentation reports on progress being made on developing a Valve Health Monitor (VHM) Smart Current Signature Sensor. Topics cover include: design needs, target valves, current signatures, VHM design approach and VHM status/conclusions.

  11. Problem: Heart Valve Regurgitation

    MedlinePlus

    ... Options • Recovery and Healthy Living Goals • Personal Stories Heart Valve Disease Symptoms Dr. Robert Bonow describes the symptoms that may alert you to heart valve disease. Support Network: You're Not Alone Popular Articles ...

  12. Overflow control valve

    DOEpatents

    Hundal, Rolv; Kessinger, Boyd A.; Parlak, Edward A.

    1984-07-24

    An overflow control valve for use in a liquid sodium coolant pump tank which valve can be extended to create a seal with the pump tank wall or retracted to break the seal thereby accommodating valve removal. An actuating shaft which controls valve disc position also has cams which bear on roller surfaces to force retraction of a sliding cylinder against spring tension to retract the cylinder from sealing contact with the pump tank.

  13. Valve technology: A compilation

    NASA Technical Reports Server (NTRS)

    1971-01-01

    A technical compilation on the types, applications and modifications to certain valves is presented. Data cover the following: (1) valves that feature automatic response to stimuli (thermal, electrical, fluid pressure, etc.), (2) modified valves changed by redesign of components to increase initial design effectiveness or give the item versatility beyond its basic design capability, and (3) special purpose valves with limited application as presented, but lending themselves to other uses with minor changes.

  14. Aerodynamic Shutoff Valve

    NASA Technical Reports Server (NTRS)

    Horstman, Raymond H.

    1992-01-01

    Aerodynamic flow achieved by adding fixed fairings to butterfly valve. When valve fully open, fairings align with butterfly and reduce wake. Butterfly free to turn, so valve can be closed, while fairings remain fixed. Design reduces turbulence in flow of air in internal suction system. Valve aids in development of improved porous-surface boundary-layer control system to reduce aerodynamic drag. Applications primarily aerospace. System adapted to boundary-layer control on high-speed land vehicles.

  15. Aerodynamic Shutoff Valve

    NASA Technical Reports Server (NTRS)

    Horstman, Raymond H.

    1992-01-01

    Aerodynamic flow achieved by adding fixed fairings to butterfly valve. When valve fully open, fairings align with butterfly and reduce wake. Butterfly free to turn, so valve can be closed, while fairings remain fixed. Design reduces turbulence in flow of air in internal suction system. Valve aids in development of improved porous-surface boundary-layer control system to reduce aerodynamic drag. Applications primarily aerospace. System adapted to boundary-layer control on high-speed land vehicles.

  16. A case of SAPIEN XT valve fallen into left ventricle during valve-in-valve transcatheter aortic valve implantation.

    PubMed

    Koizumi, Shigeki; Ehara, Natsuhiko; Nishiya, Kenta; Koyama, Tadaaki

    2017-06-24

    Late transcatheter heart valve embolization is a rare but life-threatening complication of transcatheter aortic valve implantation. Surgical intervention is performed for most cases, but some cases were treated by valve-in-valve transcatheter aortic valve implantation. We describe a patient in whom a 29-mm Edwards SAPIEN XT valve migrated into the left ventricular outflow tract 41 days after the initial implantation. We tried to perform valve-in-valve transcatheter aortic valve implantation using a transfemoral approach. As soon as the second transcatheter heart valve touched the first implanted valve, it fell into the left ventricle. Immediate surgical intervention was required. The first valve was removed, and surgical aortic valve replacement was successfully performed. In conclusion, we should choose surgical aortic valve replacement for late transcatheter heart valve embolization. Even if we need to treat by catheter intervention, transapical approach may be better.

  17. Microblower assisted barometric valve

    DOEpatents

    Rossabi, Joseph; Hyde, Warren K.; Riha, Brian D.; Jackson, Dennis G.; Sappington, Frank

    2005-12-06

    A gas exchange apparatus is provided which provides for both passive fluid flow and blower associated fluid flow through a barometric valve. A battery powered blower is provided which allows for operation of the barometric valve during times when the barometric valve would otherwise be closed, and provides for enhanced volume of gas exchange.

  18. Problem: Mitral Valve Regurgitation

    MedlinePlus

    ... Stroke Vascular Health Peripheral Artery Disease Venous Thromboembolism Aortic Aneurysm More Problem: Mitral Valve Regurgitation Updated:Sep 21,2016 What is mitral valve ... blood flows from the ventricle through the aortic valve — as it should — and some blood flows ...

  19. Dump valve assembly

    DOEpatents

    Owen, T.J.

    1984-01-01

    A dump valve assembly comprising a body having a bore defined by a tapered wall and a truncated spherical valve member adapted to seat along a spherical surface portion thereof against said tapered wall. Means are provided for pivoting said valve member between a closed position engagable with said tapered wall and an open position disengaged therefrom.

  20. Liquid rocket valve assemblies

    NASA Technical Reports Server (NTRS)

    1973-01-01

    The design and operating characteristics of valve assemblies used in liquid propellant rocket engines are discussed. The subjects considered are as follows: (1) valve selection parameters, (2) major design aspects, (3) design integration of valve subassemblies, and (4) assembly of components and functional tests. Information is provided on engine, stage, and spacecraft checkout procedures.

  1. Mitral Valve Prolapse

    PubMed Central

    Rosser, Walter W.

    1992-01-01

    The author discusses the pathophysiology of mitral valve prolapse and provides guidelines to identify and treat low-to high-risk mitral valve prolapse. An approach to diagnosing bacterial endocarditis and its prophylaxis are also discussed. The author reviews mitral valve prolapse syndrome and the risk of sudden death.

  2. Double-Poppet Valve

    NASA Technical Reports Server (NTRS)

    Huber, W. C.

    1984-01-01

    New valve design includes two poppet/seat combinations actuated simultaneously. If one fails, other continues to seal against fluid flow. Valve primarily useful for handling dangerous fluids and lighter and more compact than comparable redundant-valve systems used at present.

  3. Disk Valve For Cryogenics

    NASA Technical Reports Server (NTRS)

    Calhoun, Richard B.

    1993-01-01

    Lightweight disk valve designed to have dimensions and capabilities similar to those of valve described in "Lightweight Right-Angle Valve For Cryogenics" (MSC-21889). Simple unit remains leaktight over wide range of pressures and temperatures without need for manual readjustment of packing gland. Weighs less than 60 g and made relatively inexpensively from some commercial and few simple custom-machined components.

  4. Lock For Valve Stem

    NASA Technical Reports Server (NTRS)

    Burley, Richard K.; Guirguis, Kamal S.

    1991-01-01

    Simple, cheap device locks valve stem so its setting cannot be changed by unauthorized people. Device covers valve stem; cover locked in place with standard padlock. Valve lock made of PVC pipe and packing band. Shears, drill or punch, and forming rod only tools needed.

  5. Heart Valve Diseases

    MedlinePlus

    Your heart has four valves. Normally, these valves open to let blood flow through or out of your heart, and then shut to keep it from flowing ... close tightly. It's one of the most common heart valve conditions. Sometimes it causes regurgitation. Stenosis - when ...

  6. Pulmonary Valve Stenosis

    MedlinePlus

    ... or valve or replaces the valve with an artificial valve. Repairs to other congenital heart defects can be made during the surgery, as well. There's a slight risk of bleeding, infection or blood clots associated with the surgery. While there's little ...

  7. How Is Mitral Valve Prolapse Treated?

    MedlinePlus

    ... page from the NHLBI on Twitter. How Is Mitral Valve Prolapse Treated? Most people who have mitral valve ... all hospitals offer this method. Valve Repair and Valve Replacement In mitral valve surgery, the valve is repaired or replaced. ...

  8. Enhancing the Bounce of a Ball

    NASA Astrophysics Data System (ADS)

    Cross, Rod

    2010-10-01

    In sports such as baseball, softball, golf, and tennis, a common objective is to hit the ball as fast or as far as possible. Another common objective is to hit the ball so that it spins as fast as possible, since the trajectory of the ball through the air is strongly affected by ball spin. In an attempt to enhance both the coefficient of restitution (COR) and the spin of a golf ball, I conducted several experiments to see what would happen when a 45-g, 42.8-mm diameter golf ball bounced on: (a) a 58-mm diameter, 103-g Super Ball®; (b) an 8-mm thick, 56-mm diameter circular disk of Super Ball material cut from a large Super Ball and glued to a 3.4-kg lead brick; and (c) a 3-mm thick sheet of rubber glued to a 3.4-kg lead brick. (See Fig. 1.)

  9. Particle creation from Q-balls

    NASA Astrophysics Data System (ADS)

    Clark, Stephen S.

    2006-11-01

    Non-topological solitons, Q-balls can arise in many particle theories with U(1) global symmetries. As was shown by Cohen et al. [A.G. Cohen, S.R. Coleman, H. Georgi, A. Manohar, The evaporation of Q-balls, Nucl. Phys. B 272 (1986) 301], if the corresponding scalar field couples to massless fermions, large Q-balls are unstable and evaporate, producing a fermion flux proportional to the Q-ball's surface. In this paper we analyse Q-ball instabilities as a function of Q-ball size ans fermion mass. In particular, we construct an exact quantum-mechanical description of the evaporating Q-ball. This new construction provides an alternative method to compute Q-ball's evaporation rates. We shall also find the new expression for the upper bound on evaporation as a function of the produced fermion mass and study the effects of Q ball's size on particle production.

  10. Compact valve actuation mechanism

    NASA Technical Reports Server (NTRS)

    Brogdon, James William (Inventor); Gill, David Keith (Inventor)

    2000-01-01

    A valve actuation device. The device may include a free floating valve bridge movably supported within a cavity in the engine housing. The bridge may be provided with a cavity and an orifice arrangement for pumping gases entrained with lubricating fluid toward the piston stems as the bridge reciprocates back and forth. The device may also include a rocker arm that has a U-shaped cross-sectional shape for receiving at least a portion of the valve bridge, valve stem valve spring and spring retainer therein. The rocker arm may be provided with lubrication passages for directing lubrication to the point wherein it is pivotally affixed to the engine housing.

  11. Main Oxidizer Valve Design

    NASA Technical Reports Server (NTRS)

    Addona, Brad; Eddleman, David

    2015-01-01

    A developmental Main Oxidizer Valve (MOV) was designed by NASA-MSFC using additive manufacturing processes. The MOV is a pneumatically actuated poppet valve to control the flow of liquid oxygen to an engine's injector. A compression spring is used to return the valve to the closed state when pneumatic pressure is removed from the valve. The valve internal parts are cylindrical in shape, which lends itself to traditional lathe and milling operations. However, the valve body represents a complicated shape and contains the majority of the mass of the valve. Additive manufacturing techniques were used to produce a part that optimized mass and allowed for design features not practical with traditional machining processes.

  12. MIPP Plastic Ball electronics upgrade

    SciTech Connect

    Baldin, Boris; /Fermilab

    2009-01-01

    An upgrade electronics design for Plastic Ball detector is described. The Plastic Ball detector was a part of several experiments in the past and its back portion (proposed to be used in MIPP) consists of 340 photomultipliers equipped with a sandwich scintillator. The scintillator sandwich has fast and slow signal component with decay times 10 ns and 1 {micro}s respectively. The upgraded MIPP experiment will collect up to 12,000 events during each 4 second spill and read them out in {approx}50 seconds between spills. The MIPP data acquisition system will employ deadtime-less concept successfully implemented in Muon Electronics of Dzero experiment at Fermilab. An 8-channel prototype design of the Plastic Ball Front End (PBFE) implementing these requirements is discussed. Details of the schematic design, simulation and prototype test results are discussed.

  13. Ball lightning risk to aircraft

    NASA Astrophysics Data System (ADS)

    Doe, R.; Keul, A.

    2009-04-01

    Lightning is a rare but regular phenomenon for air traffic. Aircraft are designed to withstand lightning strikes. Research on lightning and aircraft can be called detailed and effective. In the last 57 years, 18 reported lightning aviation disasters with a fatality figure of at least 714 persons occurred. For comparison, the last JACDEC ten-year average fatality figure was 857. The majority encountered lightning in the climb, descent, approach and/or landing phase. Ball lightning, a metastable, rare lightning type, is also seen from and even within aircraft, but former research only reported individual incidents and did not generate a more detailed picture to ascertain whether it constitutes a significant threat to passenger and aircraft safety. Lacking established incident report channels, observations were often only passed on as "air-travel lore". In an effort to change this unsatisfactory condition, the authors have collected a first international dataset of 38 documented ball lightning aircraft incidents from 1938 to 2001 involving 13 reports over Europe, 13 over USA/Canada, and 7 over Russia. 18 (47%) reported ball lightning outside the aircraft, 18 (47%) inside, 2 cases lacked data. 8 objects caused minor damage, 8 major damage (total: 42%), only one a crash. No damage was reported in 18 cases. 3 objects caused minor crew injury. In most cases, ball lightning lasted several seconds. 11 (29%) incidents ended with an explosion of the object. A cloud-aircraft lightning flash was seen in only 9 cases (24%) of the data set. From the detailed accounts of air personnel in the last 70 years, it is evident that ball lightning is rarely, but consistently observed in connection with aircraft and can also occur inside the airframe. Reports often came from multiple professional witnesses and in several cases, damages were investigated by civil or military authorities. Although ball lightning is no main air traffic risk, the authors suggest that incident and accident

  14. Finger Injuries in Ball Sports.

    PubMed

    Netscher, David T; Pham, Dang T; Staines, Kimberly Goldie

    2017-02-01

    Finger injuries are common in athletes playing in professional ball sports. Understanding the intricate anatomy of the digit is necessary to properly diagnose and manage finger injuries. Unrecognized or poorly managed finger injuries can lead to chronic deformities that can affect an athlete's performance. Multiple factors and treatment options should be considered to provide the best functional outcome and rapid return to play for an athlete. This article discusses the mechanism of injury, diagnosis, treatment, and return-to-play recommendations for common finger injuries in ball sports.

  15. CAM operated fuel valve

    SciTech Connect

    Kelly, S.T.; Katchka, J.R.

    1991-09-03

    This patent describes improvement in a fuel control valve construction comprising a housing means having an inlet means adapted to be interconnected to a fuel source and a main outlet means adapted to be interconnected to a main burner means, the housing means having a main valve seat for interconnecting the inlet means with the main outlet means, the housing means having a movable main valve member for opening and closing the main valve seat, the housing means having a movable lever operatively associated with the main valve member and having a manually operable actuator means for controlling the operating positions of the lever, the lever having an intermediate cam follower portion and opposed ends disposed on each side of the cam follower portion with one end of the opposed ends being pivotally mounted to the housing means and with the other end of the opposed ends for operating the main valve member, the housing means having biasing means operatively interconnected to the lever to tend to pivot the lever in one direction that opens the main valve member away from its the main valve seat. The improvement comprises; the housing means has a thermostatically controlled means that is operatively associated with the lever and is adapted to engage and hold the lever in a position wherein the main valve member is in a closed condition against its the main valve seat when the thermostatically controlled means is in one operating condition thereof and the actuator means is in the on condition thereof.

  16. Bioprosthetic Valve Fracture Improves the Hemodynamic Results of Valve-in-Valve Transcatheter Aortic Valve Replacement.

    PubMed

    Chhatriwalla, Adnan K; Allen, Keith B; Saxon, John T; Cohen, David J; Aggarwal, Sanjeev; Hart, Anthony J; Baron, Suzanne J; Dvir, Danny; Borkon, A Michael

    2017-07-01

    Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) may be less effective in small surgical valves because of patient/prosthesis mismatch. Bioprosthetic valve fracture (BVF) using a high-pressure balloon can be performed to facilitate VIV TAVR. We report data from 20 consecutive clinical cases in which BVF was successfully performed before or after VIV TAVR by inflation of a high-pressure balloon positioned across the valve ring during rapid ventricular pacing. Hemodynamic measurements and calculation of the valve effective orifice area were performed at baseline, immediately after VIV TAVR, and after BVF. BVF was successfully performed in 20 patients undergoing VIV TAVR with balloon-expandable (n=8) or self-expanding (n=12) transcatheter valves in Mitroflow, Carpentier-Edwards Perimount, Magna and Magna Ease, Biocor Epic and Biocor Epic Supra, and Mosaic surgical valves. Successful fracture was noted fluoroscopically when the waist of the balloon released and by a sudden drop in inflation pressure, often accompanied by an audible snap. BVF resulted in a reduction in the mean transvalvular gradient (from 20.5±7.4 to 6.7±3.7 mm Hg, P<0.001) and an increase in valve effective orifice area (from 1.0±0.4 to 1.8±0.6 cm(2), P<0.001). No procedural complications were reported. BVF can be performed safely in small surgical valves to facilitate VIV TAVR with either balloon-expandable or self-expanding transcatheter valves and results in reduced residual transvalvular gradients and increased valve effective orifice area. © 2017 American Heart Association, Inc.

  17. Aligner for Elastic Collisions of Dropped Balls.

    ERIC Educational Resources Information Center

    Mellen, Walter Roy

    1995-01-01

    Discusses an aligner that permits dropping a stack of any number of balls of different sizes, elasticities, hardnesses, or types to observe the rebound of the top ball. Experimental results allow a reasonable comparison with theory. (MVL)

  18. Acting Administrator Lightfoot Visits Ball Aerospace

    NASA Image and Video Library

    2017-04-06

    Acting NASA Deputy Administrator Lesa Roe, right, speaks with Rob Strain, president of Ball Aerospace, Thursday, April 6, 2017 during a visit to Ball Aerospace in Boulder, Colo. Photo Credit: (NASA/Joel Kowsky)

  19. Valve selection in aortic valve endocarditis

    PubMed Central

    Zubrytska, Yana

    2016-01-01

    Aortic prosthetic valve endocarditis (PVE) is a potentially life-threatening disease. Mortality and incidence of infective endocarditis have been reduced in the past 30 years. Medical treatment of aortic PVE may be successful in patients who have a prompt response after antibiotic treatment and who do not have prosthetic dysfunction. In advanced stages, antibiotic therapy alone is insufficient to control the disease, and surgical intervention is necessary. Surgical treatment may be lifesaving, but it is still associated with considerable morbidity and mortality. The aim of surgery is to perform a radical excision of all infected and necrotic tissue, reconstruction of the left ventricle outflow tract, and replacement of the aortic valve. There is no unanimous consensus on which is the optimal prosthesis to implant in this context, and several surgical techniques have been suggested. We aim to analyze the efficacy of the surgical treatment and discuss the issue of valve selection in patients with aortic valve endocarditis. PMID:27785132

  20. Guide to prosthetic cardiac valves

    SciTech Connect

    Morse, D.; Steiner, R.M.; Fernandez, J.

    1985-01-01

    This book contains 10 chapters. Some of the chapter titles are: The development of artificial heart valves: Introduction and historical perspective; The radiology of prosthetic heart valves; The evaluation of patients for prosthetic valve implantation; Pathology of cardiac valve replacement; and Bioengineering of mechanical and biological heart valve substitutes.

  1. Asymptomatic Strut Fracture in DeBakey-Surgitool Aortic Valves

    PubMed Central

    Von Der Emde, Jürgen; Eberlein, Ulrich; Breme, Jürgen

    1990-01-01

    From August 1971 through November 1972, we implanted 62 Model 2 DeBakey-Surgitool aortic valve prostheses in 62 patients, 4 of whom later had clinically asymptomatic strut fractures. In 1 case, the patient died suddenly, and autopsy revealed detachment of the ball-cage; in each of the other 3 cases, fractures of 2 struts close to the base of the prosthesis were diagnosed fluoroscopically, and the patients underwent successful reoperation. The interval between implantation and reoperation ranged from 11 months to 16 years, 9 months. In 1 patient, retrospective study of chest radiographs revealed that the fracture had been present for 2½ years. Larger valves (≥ A6) were affected significantly more often than smaller ones. We performed metallurgic analysis of 1 prosthesis: results revealed strut wear from fatigue cracking and secondary abrasion. Strut fracture was also promoted by suspension of the cage at right angles to the prosthetic ring and by use of a pyrolytic carbon ball in a titanium cage (i.e., an occluder harder than its holder). Patients with DeBakey-Surgitool aortic valve prostheses should undergo annual radiologic examinations to enable early detection of strut fractures. Prophylactic valve replacement is not indicated. (Texas Heart Institute Journal 1990;17:223-7) Images PMID:15227175

  2. 2012 Problem 15: Frustrating Golf Ball

    NASA Astrophysics Data System (ADS)

    Huang, Shan; Zhu, Zheyuan; Gao, Wenli; Wang, Sihui

    2015-10-01

    This paper studies the condition for a golf ball to escape from a hole. The two determining factors are the ball's initial velocity v0 and its deviation from the center of the hole d. There is a critical escaping velocity vc for every deviation d. The ball's motion is analyzed by calculating the change of velocity whenever the ball collides with the hole. The critical conditions predicted by our theory are verified through experiment.

  3. Vertical bounce of two vertically aligned balls

    NASA Astrophysics Data System (ADS)

    Cross, Rod

    2007-11-01

    When a tennis ball rests on top of a basketball and both drop to the floor together, the tennis ball is projected vertically at high speed. A mass-spring model of the impact, as well as air track data, suggest that the tennis ball should be projected at relatively low speed. Measurements of the forces on each ball and the bounce of vertically aligned superballs are used to resolve the discrepancy.

  4. Silicon Nitride Balls For Cryogenic Bearings

    NASA Technical Reports Server (NTRS)

    Butner, Myles F.; Ng, Lillian W.

    1990-01-01

    Resistance to wear greater than that of 440C steel. Experiments show lives of ball bearings immersed in liquid nitrogen or liquid oxygen increased significantly when 440C steel balls (running on 440C steel races) replaced by balls of silicon nitride. Developed for use at high temperatures, where lubrication poor or nonexistent. Best wear life of any bearing tested to date and ball material spalls without fracturing. Plans for future tests call for use of liquid oxygen as working fluid.

  5. Does Ease to Block a Ball Affect Perceived Ball Speed? Examination of Alternative Hypotheses

    ERIC Educational Resources Information Center

    Witt, Jessica K.; Sugovic, Mila

    2012-01-01

    According to an action-specific account of perception, the perceived speed of a ball can be a function of the ease to block the ball. Balls that are easier to stop look like they are moving slower than balls that are more difficult to stop. This was recently demonstrated with a modified version of the classic computer game Pong (Witt & Sugovic,…

  6. Laboratory-produced ball lightning

    NASA Astrophysics Data System (ADS)

    Golka, Robert K., Jr.

    1994-05-01

    For 25 years I have actively been searching for the true nature of ball lightning and attempting to reproduce it at will in the laboratory. As one might expect, many unidentified lights in the atmosphere have been called ball lightning, including Texas Maffa lights (automobile headlights), flying saucers (UFOs), swamp gas in Ann Arbor, Michigan, etc. For 15 years I thought ball lightning was strictly a high-voltage phenomenon. It was not until 1984 when I was short-circuiting the electrical output of a diesel electric railroad locomotive that I realized that the phenomenon was related more to a high current. Although I am hoping for some other types of ball lightning to emerge such as strictly electrostatic-electromagnetic manifestations, I have been unlucky in finding laboratory provable evidence. Cavity-formed plasmodes can be made by putting a 2-inch burning candle in a home kitchen microwave oven. The plasmodes float around for as long as the microwave energy is present.

  7. Reflections on a Disco Ball

    ERIC Educational Resources Information Center

    Ribeiro, Jair Lúcio Prados

    2016-01-01

    A disco ball is a spherical object covered with small plane mirrors. When light reflects on these mirrors, it is scattered in many directions, producing a novel effect. The mirror globe is usually set to rotate, creating a profusion of moving spots (Fig. 1). In this article, we present a geometrical description of the movement of these spots and…

  8. Idea Bank: Wiffle Ball Physics

    ERIC Educational Resources Information Center

    Lancor, Rachael

    2009-01-01

    Projectile motion, a cornerstone topic of introductory physics, is usually a student's first exposure to the problem-solving techniques used in this subject. Often, this is an inactive learning experience--students work with pencil and paper to read and solve projectile motion problems (e.g., diagrams and descriptions of balls being hit, kicked,…

  9. Idea Bank: Wiffle Ball Physics

    ERIC Educational Resources Information Center

    Lancor, Rachael

    2009-01-01

    Projectile motion, a cornerstone topic of introductory physics, is usually a student's first exposure to the problem-solving techniques used in this subject. Often, this is an inactive learning experience--students work with pencil and paper to read and solve projectile motion problems (e.g., diagrams and descriptions of balls being hit, kicked,…

  10. Secrets of the Crystal Ball

    ERIC Educational Resources Information Center

    Croucher, John S.

    2007-01-01

    This article describes how a crystal ball known as "The Flash Mind Reader" is played. "The Flash Mind Reader" is a mathematics game in which the player is invited to select any-two digit number and then subtract the sum of these two digits from the original number. A chart is provided in which the (adjusted) number they obtained will have a symbol…

  11. Reflections on a Disco Ball

    ERIC Educational Resources Information Center

    Ribeiro, Jair Lúcio Prados

    2016-01-01

    A disco ball is a spherical object covered with small plane mirrors. When light reflects on these mirrors, it is scattered in many directions, producing a novel effect. The mirror globe is usually set to rotate, creating a profusion of moving spots (Fig. 1). In this article, we present a geometrical description of the movement of these spots and…

  12. Aortic or Mitral Valve Replacement With the Biocor and Biocor Supra

    ClinicalTrials.gov

    2016-03-09

    Aortic Valve Insufficiency; Aortic Valve Regurgitation; Aortic Valve Stenosis; Aortic Valve Incompetence; Mitral Valve Insufficiency; Mitral Valve Regurgitation; Mitral Valve Stenosis; Mitral Valve Incompetence

  13. Lightweight, high speed bearing balls: A concept

    NASA Technical Reports Server (NTRS)

    Parker, R. J.

    1974-01-01

    Low mass bearing balls with hardened iron-plated surfaces can eliminate problems of low fatigue strength and flexure fatigue, and lead to increased life and reliability of high speed ball bearings. Low mass balls exert lower centrifugal forces on outer race of bearing thus eliminating detrimental effect of high speed operation.

  14. Flare angles measured with ball gage

    NASA Technical Reports Server (NTRS)

    Cleghorn, D.; Wall, W. A.

    1968-01-01

    Precision tungsten carbide balls measure the internal angle of flared joints. Measurements from small and large balls in the flare throat to an external reference point are made. The difference in distances and diameters determine the average slope of the flare between the points of ball contact.

  15. Playing Ball in a Space Station

    ERIC Educational Resources Information Center

    Simoson, Andrew J.

    2006-01-01

    How does artificial gravity affect the path of a thrown ball? This paper contrasts ball trajectories on the Little Prince's asteroid planet B-612 and Arthur C. Clarke's rotating-drum spacecraft of 2001, and demonstrates curve balls with multiple loops in the latter environment.

  16. Playing Ball in a Space Station

    ERIC Educational Resources Information Center

    Simoson, Andrew J.

    2006-01-01

    How does artificial gravity affect the path of a thrown ball? This paper contrasts ball trajectories on the Little Prince's asteroid planet B-612 and Arthur C. Clarke's rotating-drum spacecraft of 2001, and demonstrates curve balls with multiple loops in the latter environment.

  17. Encapsulated Ball Bearings for Rotary Micro Machines

    DTIC Science & Technology

    2007-01-01

    properties between 440C stainless steel balls and silicon are quite low when compared to pure sliding motion due to the rolling nature. The frictional...fabrication of the rotary ball bearing is based on commercially available 440C stainless steel balls with a diameter, dball, of 285 µm and a lot diameter

  18. The Bouncing Ball DOES Come To Rest

    ERIC Educational Resources Information Center

    Young, Worth J.

    1970-01-01

    Considers a ball which is dropped from a height h above a flat surface and rebounds to a height rh, when r is a positive fraction less than one. The question asked is if the ball continues to fall and rebound in the same manner, how much time is required for the ball to come to rest? (RP)

  19. Intelligent Flow Control Valve

    NASA Technical Reports Server (NTRS)

    Kelley, Anthony R (Inventor)

    2015-01-01

    The present invention is an intelligent flow control valve which may be inserted into the flow coming out of a pipe and activated to provide a method to stop, measure, and meter flow coming from the open or possibly broken pipe. The intelligent flow control valve may be used to stop the flow while repairs are made. Once repairs have been made, the valve may be removed or used as a control valve to meter the amount of flow from inside the pipe. With the addition of instrumentation, the valve may also be used as a variable area flow meter and flow controller programmed based upon flowing conditions. With robotic additions, the valve may be configured to crawl into a desired pipe location, anchor itself, and activate flow control or metering remotely.

  20. Cryogenic Cam Butterfly Valve

    NASA Technical Reports Server (NTRS)

    McCormack, Kenneth J. (Inventor)

    2016-01-01

    A cryogenic cam butterfly valve has a body that includes an axially extending fluid conduit formed there through. A disc lug is connected to a back side of a valve disc and has a circular bore that receives and is larger than a cam of a cam shaft. The valve disc is rotatable for a quarter turn within the body about a lug axis that is offset from the shaft axis. Actuating the cam shaft in the closing rotational direction first causes the camming side of the cam of the cam shaft to rotate the disc lug and the valve disc a quarter turn from the open position to the closed position. Further actuating causes the camming side of the cam shaft to translate the valve disc into sealed contact with the valve seat. Opening rotational direction of the cam shaft reverses these motions.

  1. Minimally invasive valve surgery.

    PubMed

    Woo, Y Joseph; Seeburger, Joerg; Mohr, Friedrich W

    2007-01-01

    As alternatives to standard sternotomy, surgeons have developed innovative, minimally invasive approaches to conducting valve surgery. Through very small skin incisions and partial upper sternal division for aortic valve surgery and right minithoracotomy for mitral surgery, surgeons have become adept at performing complex valve procedures. Beyond cosmetic appeal, apparent benefits range from decreased pain and bleeding to improved respiratory function and recovery time. The large retrospective studies and few small prospective randomized studies are herein briefly summarized. The focus is then directed toward describing specific intraoperative technical details in current clinical use, covering anesthetic preparation, incision, mediastinal access, cardiovascular cannulation, valve exposure, and valve reconstruction. Finally, unique situations such as pulmonic valve surgery, reoperations, beating heart surgery, and robotics are discussed.

  2. JenaValve.

    PubMed

    Treede, Hendrik; Rastan, Ardawan; Ferrari, Markus; Ensminger, Stephan; Figulla, Hans-Reiner; Mohr, Friedrich-Wilhelm

    2012-09-01

    The JenaValve is a next-generation TAVI device which consists of a well-proven porcine root valve mounted on a low-profile nitinol stent. Feeler guided positioning and clip fixation on the diseased leaflets allow for anatomically correct implantation of the device without rapid pacing. Safety and efficacy of transapical aortic valve implantation using the JenaValve were evaluated in a multicentre prospective study that showed good short and midterm results. The valve was CE-mark released in Europe in September 2011. A post-market registry ensures on-going and prospective data collection in "real-world" patients. The transfemoral JenaValve delivery system will be evaluated in a first-in-man study in the near future.

  3. [Modern mitral valve surgery].

    PubMed

    Bothe, W; Beyersdorf, F

    2016-04-01

    At the beginning of the 20th century, Cutler and Levine performed the first successful surgical treatment of a stenotic mitral valve, which was the only treatable heart valve defect at that time. Mitral valve surgery has evolved significantly since then. The introduction of the heart-lung machine in 1954 not only reduced the surgical risk, but also allowed the treatment of different mitral valve pathologies. Nowadays, mitral valve insufficiency has become the most common underlying pathomechanism of mitral valve disease and can be classified into primary and secondary mitral insufficiency. Primary mitral valve insufficiency is mainly caused by alterations of the valve (leaflets and primary order chords) itself, whereas left ventricular dilatation leading to papillary muscle displacement and leaflet tethering via second order chords is the main underlying pathomechanism for secondary mitral valve regurgitation. Valve reconstruction using the "loop technique" plus annuloplasty is the surgical strategy of choice and normalizes life expectancy in patients with primary mitral regurgitation. In patients with secondary mitral regurgitation, implanting an annuloplasty is not superior to valve replacement and results in high rates of valve re-insufficiency (up to 30 % after 3 months) due to ongoing ventricular dilatation. In order to improve repair results in these patients, we add a novel subvalvular technique (ring-noose-string) to the annuloplasty that aims to prevent ongoing ventricular remodeling and re-insufficiency. In modern mitral surgery, a right lateral thoracotomy is the approach of choice with excellent repair and cosmetic results.

  4. Passively actuated valve

    SciTech Connect

    Modro, S. Michael; Ougouag, Abderrafi M.

    2005-09-20

    A passively actuated valve for isolating a high pressure zone from a low pressure zone and discontinuing the isolation when the pressure in the high pressure zone drops below a preset threshold. If the pressure in the high pressure zone drops below the preset threshold, the valve opens and allows flow from the high pressure zone to the low pressure zone. The valve remains open allowing pressure equalization and back-flow should a pressure inversion between the two pressure zone occur.

  5. Valve Health Monitoring System Utilizing Smart Instrumentation

    NASA Technical Reports Server (NTRS)

    Jensen, Scott L.; Drouant, George J.

    2006-01-01

    The valve monitoring system is a stand alone unit with network capabilities for integration into a higher level health management system. The system is designed for aiding in failure predictions of high-geared ball valves and linearly actuated valves. It performs data tracking and archiving for identifying degraded performance. The data collection types are cryogenic cycles, total cycles, inlet temperature, body temperature torsional strain, linear bonnet strain, preload position, total travel and total directional changes. Events are recorded and time stamped in accordance with the IRIG B True Time. The monitoring system is designed for use in a Class 1 Division II explosive environment. The basic configuration consists of several instrumentation sensor units and a base station. The sensor units are self contained microprocessor controlled and remotely mountable in three by three by two inches. Each unit is potted in a fire retardant substance without any cavities and limited to low operating power for maintaining safe operation in a hydrogen environment. The units are temperature monitored to safeguard against operation outside temperature limitations. Each contains 902-928 MHz band digital transmitters which meet Federal Communication Commission's requirements and are limited to a 35 foot transmission radius for preserving data security. The base-station controller correlates data from the sensor units and generates data event logs on a compact flash memory module for database uploading. The entries are also broadcast over an Ethernet network. Nitrogen purged National Electrical Manufactures Association (NEMA) Class 4 enclosures are used to house the base-station

  6. Compact gate valve

    DOEpatents

    Bobo, Gerald E.

    1977-01-01

    This invention relates to a double-disc gate valve which is compact, comparatively simple to construct, and capable of maintaining high closing pressures on the valve discs with low frictional forces. The valve casing includes axially aligned ports. Mounted in the casing is a sealed chamber which is pivotable transversely of the axis of the ports. The chamber contains the levers for moving the valve discs axially, and an actuator for the levers. When an external drive means pivots the chamber to a position where the discs are between the ports and axially aligned therewith, the actuator for the levers is energized to move the discs into sealing engagement with the ports.

  7. Engine valve driving apparatus

    SciTech Connect

    Masuda, S.; Uesugi, T.; Oda, H.

    1989-01-03

    An engine valve driving apparatus for an internal combustion engine having a cam driven engine valve is described. It consists of a camshaft rotatable in synchronism with rotation of a crankshaft of an engine and a movable cam member supported by the camshaft for axial movement and prevented from turning relative to the camshaft. The movable cam member can be axially shifted between an operative position wherein the cam member is cooperative with a member of the engine valve so as to cause an operation of the engine valve and an inoperative position wherein the cam member is out of cooperation with the member.

  8. Solid handling valve

    DOEpatents

    Williams, William R.

    1979-01-01

    The present invention is directed to a solids handling valve for use in combination with lock hoppers utilized for conveying pulverized coal to a coal gasifier. The valve comprises a fluid-actuated flow control piston disposed within a housing and provided with a tapered primary seal having a recessed seat on the housing and a radially expandable fluid-actuated secondary seal. The valve seals are highly resistive to corrosion, erosion and abrasion by the solids, liquids, and gases associated with the gasification process so as to minimize valve failure.

  9. Magnetic Check Valve

    NASA Technical Reports Server (NTRS)

    Morris, Brian G.; Bozeman, Richard J., Jr.

    1994-01-01

    Poppet in proposed check valve restored to closed condition by magnetic attraction instead of spring force. Oscillations suppressed, with consequent reduction of wear. Stationary magnetic disk mounted just upstream of poppet, also containing magnet. Valve body nonmagnetic. Forward pressure or flow would push poppet away from stationary magnetic disk so fluid flows easily around poppet. Stop in valve body prevents poppet from being swept away. When flow stopped or started to reverse, magnetic attraction draws poppet back to disk. Poppet then engages floating O-ring, thereby closing valve and preventing reverse flow. Floating O-ring facilitates sealing at low loads.

  10. Transventricular mitral valve operations.

    PubMed

    Joseph Woo, Y; McCormick, Ryan C

    2011-10-01

    We report transventricular mitral valve operations in 2 patients with severe mitral regurgitation and postinfarction left ventricular rupture and pseudoaneurysm. The first patient had direct papillary muscle involvement necessitating replacement of the mitral valve. The second patient had indirect mitral involvement allowing for placement of an atrial mitral annuloplasty ring via the left ventricle. Both patients showed no mitral valve regurgitation after replacement or repair and had uneventful postoperative recoveries. These cases demonstrate a feasible, alternative, transventricular approach to mitral valve replacement and repair.

  11. Modeling the Mitral Valve

    NASA Astrophysics Data System (ADS)

    Kaiser, Alexander

    2016-11-01

    The mitral valve is one of four valves in the human heart. The valve opens to allow oxygenated blood from the lungs to fill the left ventricle, and closes when the ventricle contracts to prevent backflow. The valve is composed of two fibrous leaflets which hang from a ring. These leaflets are supported like a parachute by a system of strings called chordae tendineae. In this talk, I will describe a new computational model of the mitral valve. To generate geometry, general information comes from classical anatomy texts and the author's dissection of porcine hearts. An MRI image of a human heart is used to locate the tips of the papillary muscles, which anchor the chordae tendineae, in relation to the mitral ring. The initial configurations of the valve leaflets and chordae tendineae are found by solving solving an equilibrium elasticity problem. The valve is then simulated in fluid (blood) using the immersed boundary method over multiple heart cycles in a model valve tester. We aim to identify features and mechanisms that influence or control valve function. Support from National Science Foundation, Graduate Research Fellowship Program, Grant DGE 1342536.

  12. Design and development of a leak tight helium II valve with low thermal impact

    NASA Technical Reports Server (NTRS)

    Mills, G. L.

    1991-01-01

    The Lambda Point Experiment is a precision measurement of the specific heat of liquid helium near the lambda point phase transition, in the low gravity of the space shuttle. It requires a valve for the helium sample chamber that operates at helium II temperature, has minimal thermal disturbance to the rest of the instrument, and is leak tight to helium II. A valve meeting these and all of the other science and engineering requirements of the mission has been developed by Ball. Initially, both torque and pressure actuated valve concepts were considered; the final flight design is pressure actuated. The rational for this decision as well as the rest of the valve design are given. The paper also discusses the manufacturing and testing of the prototype and flight valves. Test data is presented and discussed.

  13. Fate of thermal log type Q balls

    SciTech Connect

    Chiba, Takeshi; Kamada, Kohei; Kasuya, Shinta; Yamaguchi, Masahide

    2010-11-15

    We study time evolution of the Q ball in thermal logarithmic potential using lattice simulations. As the temperature decreases due to the cosmic expansion, the thermal logarithmic term in the potential is eventually overcome by a mass term, and we confirm that the Q ball transforms from the thick-wall type to the thin-wall type for a positive coefficient of radiative corrections to the mass term, as recently suggested. Moreover, we find that the Q ball finally ''melts down'' when the Q-ball solution disappears. We also discuss the effects of this phenomenon on the detectability of gravitational waves from the Q-ball formation.

  14. Ceramic Rail-Race Ball Bearings

    NASA Technical Reports Server (NTRS)

    Balzer, Mark A.; Mungas, Greg S.; Peters, Gregory H.

    2010-01-01

    Non-lubricated ball bearings featuring rail races have been proposed for use in mechanisms that are required to function in the presence of mineral dust particles in very low-pressure, dry environments with extended life. Like a conventional ball bearing, the proposed bearing would include an inner and an outer ring separated by balls in rolling contact with the races. However, unlike a conventional ball bearing, the balls would not roll in semi-circular or gothic arch race grooves in the rings: instead, the races would be shaped to form two or more rails (see figure). During operation, the motion of the balls would push dust particles into the spaces between the rails where the particles could not generate rolling resistance for the balls

  15. Non-plugging injection valve

    DOEpatents

    Carey, Jr., Henry S.

    1985-01-01

    A valve for injecting fluid into a conduit carrying a slurry subject to separation to form deposits capable of plugging openings into the conduit. The valve comprises a valve body that is sealed to the conduit about an aperture formed through the wall of the conduit to receive the fluid to be injected and the valve member of the valve includes a punch portion that extends through the injection aperture to the flow passage, when the valve is closed, to provide a clear channel into the conduit, when the valve is opened, through deposits which might have formed on portions of the valve adjacent the conduit.

  16. Understanding Heart Valve Problems and Causes

    MedlinePlus

    ... affecting the aortic valve, and can lead to aortic stenosis . Mediastinal radiation therapy (radiation to the chest) – Studies ... Disease "Innocent" Heart Murmur Problem: Valve Stenosis - Problem: Aortic Valve Stenosis - Problem: Mitral Valve Stenosis - Problem: Tricuspid Valve Stenosis - ...

  17. How Is Heart Valve Disease Treated?

    MedlinePlus

    ... and replacing it with a man-made or biological valve. Biological valves are made from pig, cow, or human ... the valve. Man-made valves last longer than biological valves and usually don’t have to be ...

  18. Valve mechanisms for at least two simultaneously actuable valves

    SciTech Connect

    Heimburg, F.

    1989-02-21

    This patent describes a valve gear for at least two valves of an internal combustion engine to be operated simultaneously on longitudinal axes, wherein the valve gear comprises a thrust device which is common to all valves and displaceable on an axis by a cam shaft and against which the valves abut by their valve stems to that displacement of the thrust device causes corresponding displacement of the valves, characterized in that the camshaft includes a single cam that is seated on the thrust device eccentrically relative to its axis causing rotation of the thrust device about its axis. When the thrust device is displaced, the thrust device is axially symmetrical, and the valve stems each abut against the thrust device at positions centered on points offset from the longitudinal axes of the valves causing rotation of the valves about their longitudinal axis when the valves are displaced.

  19. Measurements of drag and lift on smooth balls in flight

    NASA Astrophysics Data System (ADS)

    Cross, Rod; Lindsey, Crawford

    2017-07-01

    Measurements are presented on the drag and lift coefficients for three relatively smooth balls launched in air and tracked with two cameras separated horizontally by 6.4 m. The ball spin was varied in order to investigate whether the Magnus force would increase or decrease when the ball spin was increased. For one ball, the Magnus force increased. For another ball, the Magnus force decreased almost to zero after reaching a maximum. For the third ball, the Magnus force was negative at low ball spins and positive at high ball spins. For one of the balls, the ball spin increased with time as it travelled through the air.

  20. Stabbing balls and simplifying proteins.

    PubMed

    Daescu, Ovidiu; Luo, Jun

    2009-01-01

    We address the problem of stabbing a sequence of indexed balls B = {B1,B2, . . . , Bn} in R(3), where Bi (1 ball Bk; the goal is to minimise m. The problem finds applications in simplification of molecule chains for visualisation, matching and efficient searching in molecule and protein databases. We implemented the algorithm and created a web server where one can input a pdb file and get the simplified protein chains. We did experiments on thousands of proteins from the PDB Bank to estimate the simplification ratio achieved.

  1. Heimlich valve and pneumothorax

    PubMed Central

    Gogakos, Apostolos; Barbetakis, Nikolaos; Lazaridis, George; Papaiwannou, Antonis; Karavergou, Anastasia; Lampaki, Sofia; Baka, Sofia; Mpoukovinas, Ioannis; Karavasilis, Vasilis; Kioumis, Ioannis; Pitsiou, Georgia; Katsikogiannis, Nikolaos; Tsakiridis, Kosmas; Rapti, Aggeliki; Trakada, Georgia; Zissimopoulos, Athanasios; Tsirgogianni, Katerina; Zarogoulidis, Konstantinos

    2015-01-01

    The Heimlich valve is a small one-way valve used for chest drainage that empties into a flexible collection device and prevents return of gases or fluids into the pleural space. The Heimlich valve is less than 13 cm (5 inches) long and facilitates patient ambulation. Currently there are several systems in the market. It can be used in many patients instead of a traditional water seal drainage system. The Heimlich chest drainage valve was developed so that the process of draining the pleural cavity could be accomplished in a safe, relatively simple, and efficient manner. This valve system has replaced the cumbersome underwater drainage bottle system. Moreover; the Heimlich valve system connects to chest tubing and allows fluid and air to pass in one direction only. This system functions in any position, and it does not ever need to be clamped, a regulated suction can be attached to it if necessary. The valve drains into a plastic bag that can be held at any level, allowing the patient undergoing chest drainage to be ambulatory simply by carrying the bag. In the current mini review we will present the Heimlich valve system and method of insertion. PMID:25861609

  2. Coanda effect in valves

    NASA Astrophysics Data System (ADS)

    Uruba, Václav; Procházka, Pavel; Skála, Vladislav

    2016-11-01

    Coanda effect takes place in flow within valves diffuser for certain conditions. The valve plug in half-closed position forms wall-jet, which could be stable or instable, depending on geometry and other conditions. This phenomenon was subject of experimental study using time-resolved PIV technique. For the acquired data analysis the special spatio-temporal methods have been used.

  3. Heimlich valve and pneumothorax.

    PubMed

    Gogakos, Apostolos; Barbetakis, Nikolaos; Lazaridis, George; Papaiwannou, Antonis; Karavergou, Anastasia; Lampaki, Sofia; Baka, Sofia; Mpoukovinas, Ioannis; Karavasilis, Vasilis; Kioumis, Ioannis; Pitsiou, Georgia; Katsikogiannis, Nikolaos; Tsakiridis, Kosmas; Rapti, Aggeliki; Trakada, Georgia; Zissimopoulos, Athanasios; Tsirgogianni, Katerina; Zarogoulidis, Konstantinos; Zarogoulidis, Paul

    2015-03-01

    The Heimlich valve is a small one-way valve used for chest drainage that empties into a flexible collection device and prevents return of gases or fluids into the pleural space. The Heimlich valve is less than 13 cm (5 inches) long and facilitates patient ambulation. Currently there are several systems in the market. It can be used in many patients instead of a traditional water seal drainage system. The Heimlich chest drainage valve was developed so that the process of draining the pleural cavity could be accomplished in a safe, relatively simple, and efficient manner. This valve system has replaced the cumbersome underwater drainage bottle system. Moreover; the Heimlich valve system connects to chest tubing and allows fluid and air to pass in one direction only. This system functions in any position, and it does not ever need to be clamped, a regulated suction can be attached to it if necessary. The valve drains into a plastic bag that can be held at any level, allowing the patient undergoing chest drainage to be ambulatory simply by carrying the bag. In the current mini review we will present the Heimlich valve system and method of insertion.

  4. Temperature-Operated Valve

    NASA Technical Reports Server (NTRS)

    Morrison, Andrew D.

    1994-01-01

    Bimetallic valve stem positions orifice at end of inner pipe orifice so liquid flows to outlet when temperature lies within small range of preset value. If liquid too cold or too hot, orifices misaligned and liquid returned to source. Such as in shower, valve prevents outflow of dangerously hot or uncomfortably cold water.

  5. Temperature-Operated Valve

    NASA Technical Reports Server (NTRS)

    Morrison, Andrew D.

    1994-01-01

    Bimetallic valve stem positions orifice at end of inner pipe orifice so liquid flows to outlet when temperature lies within small range of preset value. If liquid too cold or too hot, orifices misaligned and liquid returned to source. Such as in shower, valve prevents outflow of dangerously hot or uncomfortably cold water.

  6. Minimally invasive valve surgery.

    PubMed

    Woo, Y Joseph

    2009-08-01

    Traditional cardiac valve replacement surgery is being rapidly supplanted by innovative, minimally invasive approaches toward the repair of these valves. Patients are experiencing benefits ranging from less bleeding and pain to faster recovery and greater satisfaction. These operations are proving to be safe, highly effective, and durable, and their use will likely continue to increase and become even more widely applicable.

  7. Linear motion valve

    NASA Technical Reports Server (NTRS)

    Chandler, J. A. (Inventor)

    1985-01-01

    The linear motion valve is described. The valve spool employs magnetically permeable rings, spaced apart axially, which engage a sealing assembly having magnetically permeable pole pieces in magnetic relationship with a magnet. The gap between the ring and the pole pieces is sealed with a ferrofluid. Depletion of the ferrofluid is minimized.

  8. Reflections on a Disco Ball

    NASA Astrophysics Data System (ADS)

    Ribeiro, Jair Lúcio Prados

    2016-12-01

    A disco ball is a spherical object covered with small plane mirrors. When light reflects on these mirrors, it is scattered in many directions, producing a novel effect. The mirror globe is usually set to rotate, creating a profusion of moving spots (Fig. 1). In this article, we present a geometrical description of the movement of these spots and an experimental activity to test the model.

  9. Keeping Your Eyes Continuously on the Ball While Running for Catchable and Uncatchable Fly Balls

    PubMed Central

    Postma, Dees B. W.; den Otter, A. Rob; Zaal, Frank T. J. M.

    2014-01-01

    When faced with a fly ball approaching along the sagittal plane, fielders need information for the control of their running to the interception location. This information could be available in the initial part of the ball trajectory, such that the interception location can be predicted from its initial conditions. Alternatively, such predictive information is not available, and running to the interception location involves continuous visual guidance. The latter type of control would predict that fielders keep looking at the approaching ball for most of its flight, whereas the former type of control would fit with looking at the ball during the early part of the ball's flight; keeping the eyes on the ball during the remainder of its trajectory would not be necessary when the interception location can be inferred from the first part of the ball trajectory. The present contribution studied visual tracking of approaching fly balls. Participants were equipped with a mobile eye tracker. They were confronted with tennis balls approaching from about 20 m, and projected in such a way that some balls were catchable and others were not. In all situations, participants almost exclusively tracked the ball with their gaze until just before the catch or until they indicated that a ball was uncatchable. This continuous tracking of the ball, even when running close to their maximum speeds, suggests that participants employed continuous visual control rather than running to an interception location known from looking at the early part of the ball flight. PMID:24670972

  10. Keeping your eyes continuously on the ball while running for catchable and uncatchable fly balls.

    PubMed

    Postma, Dees B W; den Otter, A Rob; Zaal, Frank T J M

    2014-01-01

    When faced with a fly ball approaching along the sagittal plane, fielders need information for the control of their running to the interception location. This information could be available in the initial part of the ball trajectory, such that the interception location can be predicted from its initial conditions. Alternatively, such predictive information is not available, and running to the interception location involves continuous visual guidance. The latter type of control would predict that fielders keep looking at the approaching ball for most of its flight, whereas the former type of control would fit with looking at the ball during the early part of the ball's flight; keeping the eyes on the ball during the remainder of its trajectory would not be necessary when the interception location can be inferred from the first part of the ball trajectory. The present contribution studied visual tracking of approaching fly balls. Participants were equipped with a mobile eye tracker. They were confronted with tennis balls approaching from about 20 m, and projected in such a way that some balls were catchable and others were not. In all situations, participants almost exclusively tracked the ball with their gaze until just before the catch or until they indicated that a ball was uncatchable. This continuous tracking of the ball, even when running close to their maximum speeds, suggests that participants employed continuous visual control rather than running to an interception location known from looking at the early part of the ball flight.

  11. Intermittent stuck valve after aortic valve replacement with a mechanical valve

    PubMed Central

    Luo, Wenzong; Wang, Xinxin; Li, Jing; Mu, Yun; Ni, Yiming

    2017-01-01

    Abstract Background: Intermittent stuck valve after mechanical valve replacement surgery is a very rare and severe complication. Case summary: We present 1 case of a 53-year-old woman after aortic valve replacement for severe aortic valve stenosis combined with hypertrophy septum. She was diagnosed with intermittent stuck valve only 1 day after surgery by clinical symptoms, intraoperative transoesophageal echocardiogram, and intraoperative findings. Conclusions: Although indications for concomitant myectomy during aortic valve replacement are not clear, we recommend myectomy to prevent stuck valve after St Jude Medical Regent prosthesis replacement for severe aortic valve stenosis combined with hypertrophy septum. PMID:28248877

  12. Space Vehicle Valve System

    NASA Technical Reports Server (NTRS)

    Kelley, Anthony R. (Inventor); Lindner, Jeffrey L. (Inventor)

    2014-01-01

    The present invention is a space vehicle valve system which controls the internal pressure of a space vehicle and the flow rate of purged gases at a given internal pressure and aperture site. A plurality of quasi-unique variable dimension peaked valve structures cover the purge apertures on a space vehicle. Interchangeable sheet guards configured to cover valve apertures on the peaked valve structure contain a pressure-activated surface on the inner surface. Sheet guards move outwardly from the peaked valve structure when in structural contact with a purge gas stream flowing through the apertures on the space vehicle. Changing the properties of the sheet guards changes the response of the sheet guards at a given internal pressure, providing control of the flow rate at a given aperture site.

  13. Boston Scientific Lotus valve.

    PubMed

    Meredith, Ian T; Hood, Kristin L; Haratani, Nicole; Allocco, Dominic J; Dawkins, Keith D

    2012-09-01

    As a result of recent randomised controlled trials and registry observations, transcatheter aortic valve replacement (TAVR) enjoys growing appeal for the treatment of patients at high or extreme risk from surgical aortic valve replacement. However, the current technologies and techniques have important limitations, including risk of stroke, vascular complications and paravalvular aortic regurgitation, which may in turn influence survival. While careful patient selection and screening may improve outcomes, new valve designs and iterations are required. The Lotus aortic valve replacement system is a new fully repositionable device designed to facilitate more precise delivery and minimise paravalvular regurgitation. The safety and efficacy of the Lotus valve are being studied systematically in the REPRISE clinical trial programme.

  14. Ball Screw Actuator Including a Stop with an Integral Guide

    NASA Technical Reports Server (NTRS)

    Wingett, Paul T. (Inventor); Perek, John (Inventor); Geck, Kellan (Inventor)

    2015-01-01

    An actuator includes a housing assembly, a ball nut, a ball screw, and a ball screw stop. The ball nut is rotationally mounted in the housing assembly, is adapted to receive an input torque, and is configured, upon receipt thereof, to rotate and supply a drive force. The ball screw is mounted within the housing assembly and extends through the ball nut. The ball screw has a first end and a second end, and is coupled to receive the drive force from the ball nut. The ball screw is configured, upon receipt of the drive force, to selectively translate between a stow position and a deploy position. The ball screw stop is mounted on the ball screw to translate therewith and is configured to at selectively engage the housing assembly while the ball screw is translating, and engage the ball nut when the ball screw is in the deploy position.

  15. Engine valve train system

    SciTech Connect

    Derringer, J.G.

    1986-12-09

    This patent describes a reciprocating internal combustion engine of the type having an engine block means defining at least one cylinder with an associate pair of ports, a valve located for axial movement in each of the ports with each valve normally biased to a valve closed position relative to its associate port. A rocker shaft support means is fixed to the engine block means, and a valve actuator is spaced from the valves and operable to effect reciprocation of the valves. The improvement described here comprises a rocker shaft pivotably supported by the rocker shaft support means, the rocker shaft having an axial passage adapted to be in continuous flow communication with the pressurized lubricant supply of the engine. It also includes first rocker arm pivotably supported on the rocker shaft in position for engagement with the valve actuator and with one of the valves and actuated in rocking movement whereby it can operate to effect opening and closing movement of one of the valves, and a second rocker arm pivotably supported on the rocker shaft next adjacent to the first rocker arm and operatively engaging the other one of the valves, the second rocker arm having a hydraulic cylinder means therein. A piston is sealingly journaled in the hydraulic cylinder means and located so as to permit engagement of the piston with the first rocker arm, the second rocker arm having a supply/drain passage means therein to the hydraulic cylinder means, and a drain passage which extends to the exterior of the second rocker arm and which is located in circumferentially spaced apart relationship to the supply/drain passage means.

  16. A fascial frustum valve for aortic valve replacement

    PubMed Central

    Yates, A. K.

    1971-01-01

    The promising qualities of autologous fascia lata in heart valve replacement have resulted in a search for improved methods of fascial heart valve manufacture. This paper describes a simply made and inserted and reliably competent unsupported fascial valve for aortic valve replacement. Images PMID:5576536

  17. Echocardiography in Transcatheter Aortic Valve Implantation and Mitral Valve Clip

    PubMed Central

    Luo, Huai

    2012-01-01

    Transcatheter aortic valve implantation and transcatheter mitral valve repair (MitraClip) procedures have been performed worldwide. In this paper, we review the use of two-dimensional and three-dimensional transesophageal echo for guiding transcatheter aortic valve replacement and mitral valve repair. PMID:23019387

  18. Fatigue life of high-speed ball bearings with silicon nitride balls

    NASA Technical Reports Server (NTRS)

    Parker, R. J.; Zaretsky, E. V.

    1974-01-01

    Evaluation of hot-pressed silicon nitride as a rolling-element bearing material. Two grades of hot-pressed silicon nitride balls were tested under rolling contact conditions in a five-ball fatigue tester. A digital computer program was used to predict the dynamic performance characteristics and fatigue life of high-speed ball bearings with silicon nitride balls relative to that with bearings containing steel balls. The results obtained include the finding that fatigue spalls on silicon nitride balls are similar in appearance to those obtained with typical bearing steels.

  19. Precise timing when hitting falling balls.

    PubMed

    Brenner, Eli; Driesen, Ben; Smeets, Jeroen B J

    2014-01-01

    People are extremely good at hitting falling balls with a baseball bat. Despite the ball's constant acceleration, they have been reported to time hits with a standard deviation of only about 7 ms. To examine how people achieve such precision, we compared performance when there were no added restrictions, with performance when looking with one eye, when vision was blurred, and when various parts of the ball's trajectory were hidden from view. We also examined how the size of the ball and varying the height from which it was dropped influenced temporal precision. Temporal precision did not become worse when vision was blurred, when the ball was smaller, or when balls falling from different heights were randomly interleaved. The disadvantage of closing one eye did not exceed expectations from removing one of two independent estimates. Precision was higher for slower balls, but only if the ball being slower meant that one saw it longer before the hit. It was particularly important to see the ball while swinging the bat. Together, these findings suggest that people time their hits so precisely by using the changing elevation throughout the swing to adjust the bat's movement to that of the ball.

  20. Precise timing when hitting falling balls

    PubMed Central

    Brenner, Eli; Driesen, Ben; Smeets, Jeroen B. J.

    2014-01-01

    People are extremely good at hitting falling balls with a baseball bat. Despite the ball's constant acceleration, they have been reported to time hits with a standard deviation of only about 7 ms. To examine how people achieve such precision, we compared performance when there were no added restrictions, with performance when looking with one eye, when vision was blurred, and when various parts of the ball's trajectory were hidden from view. We also examined how the size of the ball and varying the height from which it was dropped influenced temporal precision. Temporal precision did not become worse when vision was blurred, when the ball was smaller, or when balls falling from different heights were randomly interleaved. The disadvantage of closing one eye did not exceed expectations from removing one of two independent estimates. Precision was higher for slower balls, but only if the ball being slower meant that one saw it longer before the hit. It was particularly important to see the ball while swinging the bat. Together, these findings suggest that people time their hits so precisely by using the changing elevation throughout the swing to adjust the bat's movement to that of the ball. PMID:24904380

  1. Fluid Mechanics of Cricket and Tennis Balls

    NASA Astrophysics Data System (ADS)

    Mehta, Rabindra D.

    2009-11-01

    Aerodynamics plays a prominent role in defining the flight of a ball that is struck or thrown through the air in almost all ball sports. The main interest is in the fact that the ball can often deviate from its initial straight path, resulting in a curved, or sometimes an unpredictable, flight path. It is particularly fascinating that that not all the parameters that affect the flight of a ball are always under human influence. Lateral deflection in flight, commonly known as swing, swerve or curve, is well recognized in cricket and tennis. In tennis, the lateral deflection is produced by spinning the ball about an axis perpendicular to the line of flight, which gives rise to what is commonly known as the Magnus effect. It is now well recognized that the aerodynamics of sports balls are strongly dependent on the detailed development and behavior of the boundary layer on the ball's surface. A side force, which makes a ball curve through the air, can also be generated in the absence of the Magnus effect. In one of the cricket deliveries, the ball is released with the seam angled, which trips the laminar boundary layer into a turbulent state on that side. The turbulent boundary layer separates relatively late compared to the laminar layer on the other side, thereby creating a pressure difference and hence side force. The fluid mechanics of a cricket ball become very interesting at the higher Reynolds numbers and this will be discussed in detail. Of all the round sports balls, a tennis ball has the highest drag coefficient. This will be explained in terms of the contribution of the ``fuzz" drag and how that changes with Reynolds number and ball surface wear. It is particularly fascinating that, purely through historical accidents, small disturbances on the ball surface, such as the stitching on cricket balls and the felt cover on tennis balls are all about the right size to affect boundary layer transition and development in the Reynolds numbers of interest. The fluid

  2. Face-Sealing Butterfly Valve

    NASA Technical Reports Server (NTRS)

    Tervo, John N.

    1992-01-01

    Valve plate made to translate as well as rotate. Valve opened and closed by turning shaft and lever. Interactions among lever, spring, valve plate, and face seal cause plate to undergo combination of translation and rotation so valve plate clears seal during parts of opening and closing motions.

  3. Sliding-gate valve

    DOEpatents

    Usnick, George B.; Ward, Gene T.; Blair, Henry O.; Roberts, James W.; Warner, Terry N.

    1979-01-01

    This invention is a novel valve of the slidable-gate type. The valve is designed especially for long-term use with highly abrasive slurries. The sealing surfaces of the gate are shielded by the valve seats when the valve is fully open or closed, and the gate-to-seat clearance is swept with an inflowing purge gas while the gate is in transit. A preferred form of the valve includes an annular valve body containing an annular seat assembly defining a flow channel. The seat assembly comprises a first seat ring which is slidably and sealably mounted in the body, and a second seat ring which is tightly fitted in the body. These rings cooperatively define an annular gap which, together with passages in the valve body, forms a guideway extending normal to the channel. A plate-type gate is mounted for reciprocation in the guideway between positions where a portion of the plate closes the channel and where a circular aperture in the gate is in register with the channel. The valve casing includes opposed chambers which extend outwardly from the body along the axis of the guideway to accommodate the end portions of the gate. The chambers are sealed from atmosphere; when the gate is in transit, purge gas is admitted to the chambers and flows inwardly through the gate-to-seat-ring, clearance, minimizing buildup of process solids therein. A shaft reciprocated by an external actuator extends into one of the sealed chambers through a shaft seal and is coupled to an end of the gate. Means are provided for adjusting the clearance between the first seat ring and the gate while the valve is in service.

  4. Fatigue life of silicon nitride balls

    SciTech Connect

    Galbato, A.T.; Cundill, R.T.; Harris, T.A. SKF Engineering and Research Center, Nieuwegein Pennsylvania State Univ., University Park )

    1992-11-01

    Because its specific weight is 40 percent that of steel, silicon nitride has been considered as a rolling element material in very high speed ball and roller bearings. Furthermore, similar to steel components, hot pressed silicon nitride rolling components, when properly manufactured, have demonstrated the capacity to fail in a non-catastrophic manner, i.e., fatigue of the rolling contact surfaces. In this investigation, hot isostatically-pressed silicon nitride balls were endurance-tested using a NASA 5-ball rig and the results were compared against similarly tested VIMVAR M50 balls. The silicon nitride balls demonstrated fatigue lives many times those obtained for the M50 balls. Therefore it is concluded that silicon nitride can be effectively employed in applications where steel rolling element life has previously proved to be a limiting factor. 12 refs.

  5. Structural dynamic analysis of a ball joint

    NASA Astrophysics Data System (ADS)

    Hwang, Seok-Cheol; Lee, Kwon-Hee

    2012-11-01

    Ball joint is a rotating and swiveling element that is typically installed at the interface between two parts. In an automobile, the ball joint is the component that connects the control arms to the steering knuckle. The ball joint can also be installed in linkage systems for motion control applications. This paper describes the simulation strategy for a ball joint analysis, considering manufacturing process. Its manufacturing process can be divided into plugging and spinning. Then, the interested responses is selected as the stress distribution generated between its ball and bearing. In this paper, a commercial code of NX DAFUL using an implicit integration method is introduced to calculate the response. In addition, the gap analysis is performed to investigate the fitness, focusing on the response of the displacement of a ball stud. Also, the optimum design is suggested through case studies.

  6. Study of multiple cycles valves

    NASA Technical Reports Server (NTRS)

    Wichmann, H.

    1973-01-01

    A discussion is presented regarding valves which can be cycled repeatedly and are available from industry for application in the inlet system for the Pioneer Venus Probe mass spectrometer. Both solenoid type and latching type valves are considered. The study is divided into two principal areas: (1) preparation of a valve specification reflecting the requirements of the inlet system cyclic valves for the Pioneer Venus Probe mass spectrometer and the submittal of this specification to potential valve suppliers for their response and proposal; (2) preparation of a design layout of an optimum cyclic valve meeting all of the valve specification requirements.

  7. Long life valve design concepts

    NASA Technical Reports Server (NTRS)

    Jones, J. R.; Hall, A. H., Jr.

    1975-01-01

    Valve concept evaluation, final candidate selection, design, manufacture, and demonstration testing of a pneumatically actuated 10-inch hybrid poppet butterfly shutoff valve are presented. Conclusions and recommendations regarding those valve characteristics and features which would serve to guide in the formulation of future valve procurements are discussed. The pertinent design goals were temperature range of plus 200 to minus 423 F, valve inlet pressure 35 psia, actuation pressure 750 psia, main seal leakage 3 x 0.00001 sccs at 35 psia valve inlet pressure, and a storage and operating life of 10 years. The valve was designed to be compatible with RP-1, propane, LH2, LO2, He, and N2.

  8. Mesofluidic two stage digital valve

    DOEpatents

    Jansen, John F; Love, Lonnie J; Lind, Randall F; Richardson, Bradley S

    2013-12-31

    A mesofluidic scale digital valve system includes a first mesofluidic scale valve having a valve body including a bore, wherein the valve body is configured to cooperate with a solenoid disposed substantially adjacent to the valve body to translate a poppet carried within the bore. The mesofluidic scale digital valve system also includes a second mesofluidic scale valve disposed substantially perpendicular to the first mesofluidic scale valve. The mesofluidic scale digital valve system further includes a control element in communication with the solenoid, wherein the control element is configured to maintain the solenoid in an energized state for a fixed period of time to provide a desired flow rate through an orifice of the second mesofluidic valve.

  9. NEW APPROACHES: The way balls bounce

    NASA Astrophysics Data System (ADS)

    Bridge, N. James

    1998-05-01

    The bounce of a ball is a good topic for investigation at either GCSE or A-level. At King's School Canterbury pupils have experimented with both squash balls and inflatable play balls, varying the drop height, pressure and temperature and measuring the effect on bounce height, contact area and contact time. Worthwhile predictions can be made from quite simple theory and the experimental results provide ample opportunities for discussion and evaluation.

  10. Apparatus Would Measure Temperatures Of Ball Bearings

    NASA Technical Reports Server (NTRS)

    Gibson, John C.; Fredricks, Thomas H.

    1995-01-01

    Rig for testing ball bearings under radial and axial loads and measuring surface temperatures undergoing development. Includes extensible thermocouples: by means of bellows as longitudinal positioners, thermocouples driven into contact with bearing balls to sense temperatures immediately after test run. Not necessary to disassemble rig or to section balls to obtain indirect indications of maximum temperatures reached. Thermocouple measurements indicate temperatures better than temperature-sensitive paints.

  11. Multifractal properties of ball milling dynamics

    SciTech Connect

    Budroni, M. A. Pilosu, V.; Rustici, M.; Delogu, F.

    2014-06-15

    This work focuses on the dynamics of a ball inside the reactor of a ball mill. We show that the distribution of collisions at the reactor walls exhibits multifractal properties in a wide region of the parameter space defining the geometrical characteristics of the reactor and the collision elasticity. This feature points to the presence of restricted self-organized zones of the reactor walls where the ball preferentially collides and the mechanical energy is mainly dissipated.

  12. Acting Administrator Lightfoot Visits Ball Aerospace

    NASA Image and Video Library

    2017-04-06

    Acting NASA Deputy Administrator Lesa Roe, second from left, and acting NASA Administrator Robert Lightfoot, second from left, are seen with Mike Gazarik, vice president of Engineering at Ball Aerospace, left and Shawn Conley, test operations manager at Ball Aerospace, left, in front of the large semi-anechoic chamber, Thursday, April 6, 2017 during a visit to Ball Aerospace in Boulder, Colo. Photo Credit: (NASA/Joel Kowsky)

  13. Bioprosthetic Valve Fracture to Facilitate Transcatheter Valve-in-Valve Implantation.

    PubMed

    Allen, Keith B; Chhatriwalla, Adnan K; Cohen, David J; Saxon, John T; Aggarwal, Sanjeev; Hart, Anthony; Baron, Suzanne; Davis, J Russell; Pak, Alex F; Dvir, Danny; Borkon, A Michael

    2017-06-29

    Valve-in-valve transcatheter aortic valve replacement is less effective in small surgical bioprostheses. We evaluated the feasibility of bioprosthetic valve fracture with a high-pressure balloon to facilitate valve-in-valve transcatheter aortic valve replacement. In vitro bench testing on aortic tissue valves was performed on 19-mm and 21-mm Mitroflow (Sorin, Milan, Italy), Magna and Magna Ease (Edwards Lifesciences, Irvine, CA), Trifecta and Biocor Epic (St. Jude Medical, Minneapolis, MN), and Hancock II and Mosaic (Medtronic, Minneapolis, MN). High-pressure balloons Tru Dilation, Atlas Gold, and Dorado (C.R. Bard, Murray Hill, NJ) were used to determine which valves could be fractured and at what pressure fracture occurred. Mitroflow, Magna, Magna Ease, Mosaic, and Biocor Epic surgical valves were successfully fractured using high-pressures balloon 1 mm larger than the labeled valve size whereas Trifecta and Hancock II surgical valves could not be fractured. Only the internal valve frame was fractured, and the sewing cuff was never disrupted. Manufacturer's rated burst pressures for balloons were exceeded, with fracture pressures ranging from 8 to 24 atmospheres depending on the surgical valve. Testing further demonstrated that fracture facilitated the expansion of previously constrained, underexpanded transcatheter valves (both balloon and self-expanding) to the manufacturer's recommended size. Bench testing demonstrates that the frame of most, but not all, bioprosthetic surgical aortic valves can be fractured using high-pressure balloons. The safety of bioprosthetic valve fracture to optimize valve-in-valve transcatheter aortic valve replacement in small surgical valves requires further clinical investigation. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  14. Telescoping magnetic ball bar test gage

    DOEpatents

    Bryan, J.B.

    1984-03-13

    A telescoping magnetic ball bar test gage for determining the accuracy of machine tools, including robots, and those measuring machines having non-disengageable servo drives which cannot be clutched out is disclosed. Two gage balls are held and separated from one another by a telescoping fixture which allows them relative radial motional freedom but not relative lateral motional freedom. The telescoping fixture comprises a parallel reed flexure unit and a rigid member. One gage ball is secured by a magnetic socket knuckle assembly which fixes its center with respect to the machine being tested. The other gage ball is secured by another magnetic socket knuckle assembly which is engaged or held by the machine in such manner that the center of that ball is directed to execute a prescribed trajectory, all points of which are equidistant from the center of the fixed gage ball. As the moving ball executes its trajectory, changes in the radial distance between the centers of the two balls caused by inaccuracies in the machine are determined or measured by a linear variable differential transformer (LVDT) assembly actuated by the parallel reed flexure unit. Measurements can be quickly and easily taken for multiple trajectories about several different fixed ball locations, thereby determining the accuracy of the machine. 3 figs.

  15. Telescoping magnetic ball bar test gage

    DOEpatents

    Bryan, J.B.

    1982-03-15

    A telescoping magnetic ball bar test gage for determining the accuracy of machine tools, including robots, and those measuring machines having non-disengagable servo drives which cannot be clutched out. Two gage balls are held and separated from one another by a telescoping fixture which allows them relative radial motional freedom but not relative lateral motional freedom. The telescoping fixture comprises a parallel reed flexure unit and a rigid member. One gage ball is secured by a magnetic socket knuckle assembly which fixes its center with respect to the machine being tested. The other gage ball is secured by another magnetic socket knuckle assembly which is engaged or held by the machine in such manner that the center of that ball is directed to execute a prescribed trajectory, all points of which are equidistant from the center of the fixed gage ball. As the moving ball executes its trajectory, changes in the radial distance between the centers of the two balls caused by inaccuracies in the machine are determined or measured by a linear variable differential transformer (LVDT) assembly actuated by the parallel reed flexure unit. Measurements can be quickly and easily taken for multiple trajectories about several different fixed ball locations, thereby determining the accuracy of the machine.

  16. Telescoping magnetic ball bar test gage

    DOEpatents

    Bryan, James B.

    1984-01-01

    A telescoping magnetic ball bar test gage for determining the accuracy of machine tools, including robots, and those measuring machines having non-disengageable servo drives which cannot be clutched out. Two gage balls (10, 12) are held and separated from one another by a telescoping fixture which allows them relative radial motional freedom but not relative lateral motional freedom. The telescoping fixture comprises a parallel reed flexure unit (14) and a rigid member (16, 18, 20, 22, 24). One gage ball (10) is secured by a magnetic socket knuckle assembly (34) which fixes its center with respect to the machine being tested. The other gage ball (12) is secured by another magnetic socket knuckle assembly (38) which is engaged or held by the machine in such manner that the center of that ball (12) is directed to execute a prescribed trajectory, all points of which are equidistant from the center of the fixed gage ball (10). As the moving ball (12) executes its trajectory, changes in the radial distance between the centers of the two balls (10, 12) caused by inaccuracies in the machine are determined or measured by a linear variable differential transformer (LVDT) assembly (50, 52, 54, 56, 58, 60) actuated by the parallel reed flexure unit (14). Measurements can be quickly and easily taken for multiple trajectories about several different fixed ball (10) locations, thereby determining the accuracy of the machine.

  17. Effect of ball geometry on endurance limit in bending of drilled balls

    NASA Technical Reports Server (NTRS)

    Munson, H. E.

    1975-01-01

    Four designs of drilled (cylindrically hollow) balls were tested for resistance to bending fatigue. Bending fatigue has been demonstrated to be a limiting factor in previous evaluations of the drilled ball concept. A web reinforced drilled ball was most successful in resisting bending fatigue. Another design of through drilled design, involving a heavier wall than the standard reference ball, also showed significant improvement in resistance to bending fatigue.

  18. The Soccer-Ball Problem

    NASA Astrophysics Data System (ADS)

    Hossenfelder, Sabine

    2014-07-01

    The idea that Lorentz-symmetry in momentum space could be modified but still remain observer-independent has received quite some attention in the recent years. This modified Lorentz-symmetry, which has been argued to arise in Loop Quantum Gravity, is being used as a phenomenological model to test possibly observable effects of quantum gravity. The most pressing problem in these models is the treatment of multi-particle states, known as the 'soccer-ball problem'. This article briefly reviews the problem and the status of existing solution attempts.

  19. The Controllable Ball Joint Mechanism

    NASA Astrophysics Data System (ADS)

    Tung, Yung Cheng; Chieng, Wei-Hua; Ho, Shrwai

    A controllable ball joint mechanism with three rotational degrees of freedom is proposed in this paper. The mechanism is composed of three bevel gears, one of which rotates with respect to a fixed frame and the others rotate with respect to individual floating frames. The output is the resultant motion of the differential motions by the motors that rotates the bevel gears at the fixed frame and the floating frames. The mechanism is capable of a large rotation, and the structure is potentially compact. The necessary inverse and forward kinematic analyses as well as the derivation of kinematic singularity are provided according to the kinematical equivalent structure described in this paper.

  20. Two-ball Newton's cradle.

    PubMed

    Glendinning, Paul

    2011-12-01

    Newton's cradle for two balls with Hertzian interactions is considered as a hybrid system, and this makes it possible to derive return maps for the motion between collisions in an exact form despite the fact that the three-halves interaction law cannot be solved in closed form. The return maps depend on a constant whose value can only be determined numerically, but solutions can be written down explicitly in terms of this parameter, and we compare this with the results of simulations. The results are in fact independent of the details of the interaction potential.

  1. A Comparative Study of Two Types of Ball-on-Ball Collision

    ERIC Educational Resources Information Center

    White, Colin

    2017-01-01

    This paper describes three methods of measuring the coefficient of restitution (CoR) for two different types of ball-on-ball collision. The first collision type (for which two different CoR measurement procedures are described) is a static, hanging steel ball forming part of a Newton's cradle arrangement, which is then hit by its adjacent…

  2. Mitral Valve Prolapse.

    ERIC Educational Resources Information Center

    Bergy, Gordon G.

    1980-01-01

    Mitral valve prolapse is the most common heart disease seen in college and university health services. It underlies most arrhythmia and many chest complaints. Activity and exercise restrictions are usually unnecessary. (Author/CJ)

  3. Mitral valve regurgitation

    MedlinePlus

    ... your provider and dentist if you have a history of heart valve disease or congenital heart disease before treatment. Some people ... In: Goldman L, Schafer AI, eds. Goldman's Cecil Medicine . 25th ed. Philadelphia, PA: Elsevier Saunders; 2016:chap ...

  4. Mitral Valve Prolapse

    MedlinePlus

    ... Peripheral Vascular Disease Rheumatic Fever Sick Sinus Syndrome Silent Ischemia Stroke Sudden Cardiac Arrest Valve Disease Vulnerable ... a stethoscope, your doctor may hear a "clicking" sound caused by the flapping of the leaflets. What ...

  5. Mitral Valve Prolapse.

    ERIC Educational Resources Information Center

    Bergy, Gordon G.

    1980-01-01

    Mitral valve prolapse is the most common heart disease seen in college and university health services. It underlies most arrhythmia and many chest complaints. Activity and exercise restrictions are usually unnecessary. (Author/CJ)

  6. Flow metering valve

    DOEpatents

    Blaedel, K.L.

    1983-11-03

    An apparatus for metering fluids at high pressures of about 20,000 to 60,000 psi is disclosed. The apparatus includes first and second plates which are positioned adjacent each other to form a valve chamber. The plates are made of materials which have substantially equal elastic properties. One plate has a planar surface area, and the other a recessed surface area defined by periphery and central lips. When the two plates are positioned in adjacent contacting relationship, a valve chamber is formed between the planar surface area and the recessed surface area. Fluid is introduced into the chamber and exits therefrom when a deformation occurs at positions where they no longer form a valve seat. This permits the metering of fluids at high pressures and at slow variable rates. Fluid then exits from the chamber until an applied external force becomes large enough to bring the valve seats back into contact.

  7. Flow metering valve

    DOEpatents

    Blaedel, Kenneth L.

    1985-01-01

    An apparatus for metering fluids at high pressures of about 20,000 to 60,000 psi is disclosed. The apparatus includes first and second plates which are positioned adjacent each other to form a valve chamber. The plates are made of materials which have substantially equal elastic properties. One plate has a planar surface area, and the other a recessed surface area defined by periphery and central lips. When the two plates are positioned in adjacent contacting relationship, a valve chamber is formed between the planar surface area and the recessed surface area. Fluid is introduced into the chamber and exits therefrom when a deformation occurs at positions where they no longer form a valve seat. This permits the metering of fluids at high pressures and at slow variable rates. Fluid then exits from the chamber until an applied external force becomes large enough to bring the valve seats back into contact.

  8. Get valves repaired properly

    SciTech Connect

    Robert, R.W.

    1988-02-01

    Valve users are generally unanimous in their dissatisfaction with valve reconditioning programs. Their dissatisfaction is expressed in three complaints: poor service, poor quality and total costs which often approach or exceed valve replacement costs. These complaints are clearly legitimate, and the providers of valve reconditioning services must shoulder a significant part of the blame. However, scrutiny of the reasons for dissatisfaction reveals that some portion of the blame must also be borne by the users. Since many of the practices that cause the user's complaints are rooted in the early development of this market, a review of that development is helpful in understanding how these problems arose, and leads to a better understanding of the steps necessary for improvement.

  9. Bidirectional piston valve

    DOEpatents

    Fischer, Harry C.

    1977-01-01

    This invention is a reversing valve having an inlet, an outlet, and an inlet-outlet port. The valve is designed to respond to the introduction of relatively high-pressure fluid at its inlet or, alternatively, of lower-pressure fluid at its inlet-outlet port. The valve includes an axially slidable assembly which is spring-biased to a position where it isolates the inlet and connects the inlet-outlet port to the outlet. The admission of high-pressure fluid to the inlet displaces the slidable assembly to a position where the outlet is isolated and the inlet is connected to the inlet-outlet port. The valve is designed to minimize pressure drops and leakage. It is of a reliable and comparatively simple design.

  10. THERMALLY OPERATED VAPOR VALVE

    DOEpatents

    Dorward, J.G. Jr.

    1959-02-10

    A valve is presented for use in a calutron to supply and control the vapor to be ionized. The invention provides a means readily operable from the exterior of the vacuum tank of the apparatuss without mechanical transmission of forces for the quick and accurate control of the ionizing arc by a corresponding control of gas flow theretos thereby producing an effective way of carefully regulating the operation of the calutron. The invention consists essentially of a tube member extending into the charge bottle of a calutron devices having a poppet type valve closing the lower end of the tube. An electrical heating means is provided in the valve stem to thermally vary the length of the stem to regulate the valve opening to control the flow of material from the charge bottle.

  11. Mitral Valve Prolapse

    MedlinePlus

    ... valve. MVP puts you at risk for infective endocarditis, a kind of heart infection. To prevent it, ... surgeries. Now, only people at high risk of endocarditis need the antibiotics. NIH: National Heart, Lung, and ...

  12. Valve for gas centrifuges

    DOEpatents

    Hahs, Charles A.; Burbage, Charles H.

    1984-01-01

    The invention is a pneumatically operated valve assembly for simultaneously (1) closing gas-transfer lines connected to a gas centrifuge or the like and (2) establishing a recycle path between two of the lines so closed. The valve assembly is especially designed to be compact, fast-acting, reliable, and comparatively inexpensive. It provides large reductions in capital costs for gas-centrifuge cascades.

  13. Bicuspid Aortic Valve

    DTIC Science & Technology

    2006-08-01

    Schnell E, Wollenek G, Maurer G, Baumgartner H, Lang IM. Mechanisms underlying aortic dilatation in congenital aortic valve malformation . Circulation...1999; 99(16):2138-2143. 10. Roberts CS, Roberts WC. Dissection of the aorta associated with congenital malformation of the aortic valve. J Am Coll... congenital heart defect, often diagnosed incidentally or as a consequence of an associated condition. Patients with this anomaly are at increased risk

  14. Piston and valve assembly

    SciTech Connect

    Rolder, G. K.

    1985-10-01

    A downhole hydraulically actuated pump assembly of either the free or fixed type lifts formation fluid from the bottom of a borehole to the surface of the ground. The downhole pump has a power piston which actuates a production plunger. A valve means is concentrically arranged within the power piston. A stationary, hollow valve control rod extends through the power piston and through the valve means, with a lower marginal end of the control rod terminating within the production plunger. Power fluid flows through the control rod and to the valve means. As the power piston reciprocates within the engine cylinder, means on the control rod actuates the valve means between two alternant positions so that power fluid is applied to the bottom face of the power piston to thereby cause the power piston to reciprocate upward; and thereafter, the control rod causes the valve means to shift to the other position, whereupon spent power fluid is exhausted from the engine cylinder. The spent power fluid is admixed with production fluid and is conducted to the surface of the ground.

  15. Engine valve train module

    SciTech Connect

    Wirth, R.C.; De Klep, E.L.

    1988-01-26

    In a reciprocating internal combustion engine of the type having an engine block means defining at least one cylinder with a first port and a second port in flow communication therewith, a first valve and a second valve reciprocably located to control flow through the first and second ports, respectively, and normally biased to a port closed position, the improvement is described comprising a valve train module that includes a housing adapted to be secured by machine screws to the engine block means above the first and second valves; an engine driven camshaft having axial spaced apart first and second cam lobes operatively supported for rotation in the housing; a lifter guide bore in the housing located substantially coaxial with the reciprocating axis of the first valve; a direct acting hydraulic lash adjuster operatively supported in the lifter guide bore with one end thereof engaging the first cam lobe and at its opposite end being operatively connected to the first valve. A follower guide bore is in the housing operatively aligned relative to the second cam lobe; a hollow rocker shaft is operatively fixed in the housing in parallel spaced apart relationship to the engine driven camshaft; a rocker arm pivotably supported intermediate its ends by the rocker shaft.

  16. A Case with Recurrent Free-Floating Ball Thrombi in Left Atrium

    PubMed Central

    Yoshioka, Takayuki; Mori, Takeshige; Taniguchi, Yayoi; Hirayama, Sonoko; Ozawa, Toru; Iwata, Sachiyo; Takei, Asumi; Inoue, Nobutaka

    2017-01-01

    Patient: Female, 74 Final Diagnosis: Left atrial ball thrombus Symptoms: Abdominal discomfort • dyspnea Medication: — Clinical Procedure: — Specialty: Cardiology Objective: Rare disease Background: A free-floating ball thrombus in the left atrium is a rare clinical condition. However, the diagnosis of this condition has been facilitated by the advent and development of echocardiography and multi-detector row computed tomography (MDCT) and several cases have been reported. Case Report: We report a case of a 75-year-old woman who had recurrent giant spherical thrombi in the left atrium. She was diagnosed with chronic atrial fibrillation at 52 years of age. A pacemaker implantation was performed at 54 years of age because of a complete atrioventricular block; and mitral valve replacement was performed for severe mitral regurgitation at 62 years of age. She had a history of cerebral infarction and she was under treatment for chronic heart failure. Despite intensive anticoagulant therapy, she developed ball thrombi in the left atrium three times in six months. During hospitalization for acute myocardial infarction treated with percutaneous catheter intervention, transthoracic echocardiography and computed tomography (CT) revealed a free-floating giant spherical thrombus in the left atrium. She was treated with intensive anticoagulation therapy and the left atrial ball thrombus disappeared; however, two ball thrombi in the left atrium and left atrial appendage recurred after three months. Surgical removal of the thrombi and closure of the left atrial appendage were performed. Unfortunately, a ball thrombus in the left atrium recurred again after a further three months. Conclusions: The present case highlights the difficulty of treating refractory thrombi in the left atrium. PMID:28360410

  17. NCI and Leidos Play Ball | Poster

    Cancer.gov

    By Carolynne Keenan, Contributing Writer The ping of an aluminum bat off a ball or the thump of a pop-up fly ball caught in a glove are two sounds familiar to baseball fans. Slow-pitch softball sounds—like those in the August game between mixed teams of NCI and Leidos Biomedical Research (formerly SAIC-Frederick) players—are similar.

  18. Soccer Ball Lift Coefficients via Trajectory Analysis

    ERIC Educational Resources Information Center

    Goff, John Eric; Carre, Matt J.

    2010-01-01

    We performed experiments in which a soccer ball was launched from a machine while two high-speed cameras recorded portions of the trajectory. Using the trajectory data and published drag coefficients, we extracted lift coefficients for a soccer ball. We determined lift coefficients for a wide range of spin parameters, including several spin…

  19. Soccer Ball Lift Coefficients via Trajectory Analysis

    ERIC Educational Resources Information Center

    Goff, John Eric; Carre, Matt J.

    2010-01-01

    We performed experiments in which a soccer ball was launched from a machine while two high-speed cameras recorded portions of the trajectory. Using the trajectory data and published drag coefficients, we extracted lift coefficients for a soccer ball. We determined lift coefficients for a wide range of spin parameters, including several spin…

  20. Using Ruby Balls As Fiducial Marks

    NASA Technical Reports Server (NTRS)

    Painter, Nance M.

    1990-01-01

    Combination of basic and advanced techniques yields new capability for inspection. In new technique, surface first inspected with fluorescent penetrant dye to reveal flaws. Ruby ball of known diameter placed near flaw having to be measured. Flaw and ball observed through magnifying video system that can "freeze" image.

  1. Ball Bounce Experiment. Grades 3-5.

    ERIC Educational Resources Information Center

    Rushton, Erik; Ryan, Emily; Swift, Charles

    Many of today's popular sports are based around the use of a ball yet none are alike. In fact, they are all designed with specific characteristics in mind. In this activity, students investigate different balls' ability to bounce and represent the data they collect graphically. This activity uses a time frame of 100 minutes. (Author/SOE)

  2. Some Mathematics and Physics of Ball Games.

    ERIC Educational Resources Information Center

    Hughes, D. E.

    1985-01-01

    Gives examples on the applications of arithmetic, geometry, and some calculus, vector algebra, and mechanics to ball games. Suggestions for further interesting investigations are provided together with references to other articles and books on applications of mathematics and physics to ball games and sports in general. (JN)

  3. Acting Administrator Lightfoot Visits Ball Aerospace

    NASA Image and Video Library

    2017-04-06

    Acting NASA Administrator Robert Lightfoot, left, views a clean room with Tim Schoenweis, senior project engineer for the Ozone Mapping Profiler Suite (OMPS) at Ball Aerospace, right, Thursday, April 6, 2017 at Ball Aerospace in Boulder, Colo. Photo Credit: (NASA/Joel Kowsky)

  4. Acting Administrator Lightfoot Visits Ball Aerospace

    NASA Image and Video Library

    2017-04-06

    Acting NASA Deputy Administrator Lesa Roe, center, views a clean room with Tim Schoenweis, senior project engineer for the Ozone Mapping Profiler Suite (OMPS) at Ball Aerospace, left, Thursday, April 6, 2017 at Ball Aerospace in Boulder, Colo. Photo Credit: (NASA/Joel Kowsky)

  5. NCI and Leidos Play Ball | Poster

    Cancer.gov

    By Carolynne Keenan, Contributing Writer The ping of an aluminum bat off a ball or the thump of a pop-up fly ball caught in a glove are two sounds familiar to baseball fans. Slow-pitch softball sounds—like those in the August game between mixed teams of NCI and Leidos Biomedical Research (formerly SAIC-Frederick) players—are similar.

  6. The principal time balls of New Zealand

    NASA Astrophysics Data System (ADS)

    Kinns, Roger

    2017-04-01

    Accurate time signals in New Zealand were important for navigation in the Pacific. Time balls at Wellington and Lyttelton were noted in the 1880 Admiralty list of time signals, with later addition of Otago. The time ball service at Wellington started in March 1864 using the first official observatory in New Zealand, but there was no Wellington time ball service during a long period of waterfront redevelopment during the 1880s. The time ball service restarted in November 1888 at a different harbour location. The original mechanical apparatus was used with a new ball, but the system was destroyed by fire in March 1909 and was never replaced. Instead, a time light service was inaugurated in 1912. The service at Lyttelton, near Christchurch, began in December 1876 after construction of the signal station there. It used telegraph signals from Wellington to regulate the time ball. By the end of 1909, it was the only official time ball in New Zealand, providing a service that lasted until 1934. The Lyttelton time ball tower was an iconic landmark in New Zealand that had been carefully restored. Tragically, the tower collapsed in the 2011 earthquakes and aftershocks that devastated Christchurch. A daily time ball service at Port Chalmers, near Dunedin, started in June 1867, initially using local observatory facilities. The service appears to have been discontinued in October 1877, but was re-established in April 1882 as a weekly service, with control by telegraph from Wellington. The service had been withdrawn altogether by the end of 1909. Auckland never established a reliable time ball service, despite provision of a weekly service for mariners by a public-spirited citizen between August 1864 and June 1866. A time ball was finally installed on the Harbour Board building in 1901, but the signal was unreliable and it ceased in 1902. Complaints from ships' masters led to various proposals to re-establish a service. These concluded with erection of a time ball on the new

  7. Bending stresses in spherically hollow ball bearing and fatigue experiments

    NASA Technical Reports Server (NTRS)

    Nypan, L. J.; Coe, H. H.; Parker, R. J.

    1975-01-01

    Spherically hollow balls of 21.7, 50.0, and 56.5 percent mass reduction were operated in ball bearings and in a five-ball fatigue tester with differing outcomes. Available theoretical and experimental treatments of stresses in spherically hollow balls are reviewed and compared. Bending stresses are estimated for these spherically hollow balls to better understand the differences in ball bearing and fatigue test experience.

  8. Mitral disc-valve variance

    PubMed Central

    Berroya, Renato B.; Escano, Fernando B.

    1972-01-01

    This report deals with a rare complication of disc-valve prosthesis in the mitral area. A significant disc poppet and struts destruction of mitral Beall valve prostheses occurred 20 and 17 months after implantation. The resulting valve incompetence in the first case contributed to the death of the patient. The durability of Teflon prosthetic valves appears to be in question and this type of valve probably will be unacceptable if there is an increasing number of disc-valve variance in the future. Images PMID:5017573

  9. Ball bearing heat analysis program (BABHAP)

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The Ball Bearing Heat Analysis Program (BABHAP) is an attempt to assemble a series of equations, some of which are non-linear algebraic systems, in a logical order, which when solved, provide a complex analysis of load distribution among the balls, ball velocities, heat generation resulting from friction, applied load, and ball spinning, minimum lubricant film thickness, and many additional characteristics of ball bearing systems. Although initial design requirements for BABHAP were dictated by the core limitations of the PDP 11/45 computer, (approximately 8K of real words with limited number of instructions) the program dimensions can easily be expanded for large core computers such as the UNIVAC 1108. The PDP version of BABHAP is also operational on the UNIVAC system with the exception that the PDP uses 029 punch and the UNIVAC uses 026. A conversion program was written to allow transfer between machines.

  10. Valve health monitoring system utilizing smart instrumentation

    NASA Astrophysics Data System (ADS)

    Jensen, Scott L.; Drouant, George J.

    2006-05-01

    The valve monitoring system is a stand alone unit with network capabilities for integration into a higher level health management system. The system is designed for aiding in failure predictions of high-geared ball valves and linearly actuated valves. It performs data tracking and archiving for identifying degraded performance. The data collection types are: cryogenic cycles, total cycles, inlet temperature, outlet temperature, body temperature, torsional strain, linear bonnet strain, preload position, total travel, and total directional changes. Events are recorded and time stamped in accordance with the IRIG B True Time. The monitoring system is designed for use in a Class 1 Division II explosive environment. The basic configuration consists of several instrumentation sensor units and a base station. The sensor units are self contained microprocessor controlled and remotely mountable in three by three by two inches. Each unit is potted in a fire retardant substance without any cavities and limited to low operating power for maintaining safe operation in a hydrogen environment. The units are temperature monitored to safeguard against operation outside temperature limitations. Each contains 902-928 MHz band digital transmitters which meet Federal Communication Commissions requirements and are limited to a 35 foot transmission radius for preserving data security. The base-station controller correlates related data from the sensor units and generates data event logs on a compact flash memory module for database uploading. The entries are also broadcast over an Ethernet network. Nitrogen purged National Electrical Manufactures Association (NEMA) Class 4 Enclosures are used to house the base-station.

  11. Perceval Sutureless Valve – are Sutureless Valves Here?

    PubMed Central

    Chandola, Rahul; Teoh, Kevin; Elhenawy, Abdelsalam; Christakis, George

    2015-01-01

    With the advent of transcatheter aortic valve implantation (TAVI) techniques, a renewed interest has developed in sutureless aortic valve concepts in the last decade. The main feature of sutureless aortic valve implantation is the speed of insertion, thus making implantation easier for the surgeon. As a result, cross clamp times and myocardial ischemia may be reduced. The combined procedures (CABG with AVR in particular) can be done with a short cross clamp time. Perceval valve also provides an increased effective orifice area as compared with a stented bioprosthesis. Sutureless implantation of the Perceval valve is not only associated with shorter cross-clamp and cardiopulmonary bypass times but improved clinical outcomes too. This review covers the sutureless aortic valves and their evolution, with elaborate details on Perceval S valve in particular (which is the most widely used sutureless valve around the globe). PMID:25394851

  12. 9. BUTTERFLY VALVE CONTROL DIABLO POWERHOUSE. BUTTERFLY VALVES WERE MANUFACTURED ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. BUTTERFLY VALVE CONTROL DIABLO POWERHOUSE. BUTTERFLY VALVES WERE MANUFACTURED BY THE PELTON WATER WHEEL COMPANY IN 1931, 1989. - Skagit Power Development, Diablo Powerhouse, On Skagit River, 6.1 miles upstream from Newhalem, Newhalem, Whatcom County, WA

  13. Implantation of the CoreValve percutaneous aortic valve.

    PubMed

    Lamarche, Yoan; Cartier, Raymond; Denault, André Y; Basmadjian, Arsène; Berry, Colin; Laborde, Jean-Claude; Bonan, Raoul

    2007-01-01

    Surgical aortic valve replacement is the only recommended treatment for significant aortic valve stenosis. Percutaneous aortic valve replacement appears to be a novel option for high-risk patients. We report the implantation of the ReValving system (CoreValve, Paris, France) in a 64-year-old woman who was refused aortic valve replacement surgery for critical aortic stenosis and left ventricular dysfunction because of severe pulmonary fibrosis. After anesthesia, the patient was put on femorofemoral cardiopulmonary bypass, and underwent a balloon valvuloplasty with subsequent retrograde aortic valve replacement by the ReValving system. Transesophageal echocardiographic monitoring of the patient's hemodynamics showed immediate improvements of the valvular area and left ventricular ejection fraction and only traces of paravalvular leaks. The patient was easily weaned from ventilation and resumed activity soon after the surgery. A multidisciplinary approach is presently necessary to offer a reliable and safe procedure.

  14. [Ileocecal valve reconstruction in dogs].

    PubMed

    Maegawa, Felipe Antonio Boff; de Souza, José Antônio; de Araújo, Edevard José; Koh, Ivan Hong Jun; d'Acampora, Armando José; de Farias, Débora Cadore; Mengarda, Jackson; Volpato, Daniel; da Silva, Luis Gustavo Ferreira; de Córdova, Cleta Selva

    2005-01-01

    The importance of keeping the ileocecal valve in the intestinal ressections has been reported by several authors. When preserved, the ileocecal valve was related to a longer survival and prevention of the short bowel syndrome, due to its ability to block the colonic content reflux into the ileum and to avoid the rapid empting of the ileal content into the cecum. It was assessed a tecnique of ileocecal valve reconstitution, based on vesicoureteral anti-reflux tecniques. Fourteen beagles were operated. Seven underwent ileocecal valve reconstitution following the tecnique proposed and in the other seven a simple end-to-end anastomosis was performed. To assess the new valve, it was done the clinical follow up, the microbiologic analysis and the manometric study. Clinically, during 45 days of follow up, there was no difference between the dogs with and without ileocecal reconstitution. In the aerobic bacteria analysis, the predominant bacterium was Escherichia coli. Quantitatively, the cultures grew in an irregular way, so that it was not able to compare the bacterial growth between the groups with or without ileocecal valve. The new valve had a colo-ileal reflux pressure similar to that of the physiological valve (P > 0.05). However, when compared to the non valve group, the reflux pressures of the physiological valve and new valve were significantly higher, with P < 0.05 and P < 0.001, respectively. In this study, the reconstituted ileocecal valve served as a barrier to the colo-ileal reflux just as the physiological valve does.

  15. Ready for the Cosmic Ball

    NASA Technical Reports Server (NTRS)

    2006-01-01

    Something appears to be peering through a shiny red mask, in this new false-colored image from NASA's Spitzer Space Telescope. The mysterious blue eyes are actually starlight from the cores of two merging galaxies, called NGC 2207 and IC 2163. The mask is the galaxies' dusty spiral arms.

    NGC 2207 and IC 2163 recently met and began a sort of gravitational tango about 40 million years ago. The two galaxies are tugging at each other, stimulating new stars to form. Eventually, this cosmic ball will come to an end, when the galaxies meld into one. The dancing duo is located 140 million light-years away in the Canis Major constellation.

    The Spitzer image reveals that the galactic mask is adorned with strings of pearl-like beads. These dusty clusters of newborn stars, called 'beads on a string' by astronomers, appear as white balls throughout the arms of both galaxies. They were formed when the galaxies first interacted, forcing dust and gas to clump together into colonies of stars.

    This type of beading has been seen before in other galaxies, but it took Spitzer's infrared eyes to identify them in NGC 2207 and IC 2163. Spitzer was able to see the beads because the stars inside heat up surrounding dust, which then radiates with infrared light.

    The biggest bead lighting up the left side of the mask is also the densest. In fact, some of its central stars might have merged to form a black hole. (Now, that would be quite the Mardi Gras mask!)

    This picture, taken by Spitzer's infrared array camera, is a four-channel composite. It shows light with wavelengths of 3.6 microns (blue); 4.5 microns (green); and 5.8 and 8.0 microns (red). The contribution from starlight (measured at 3.6 microns) has been subtracted from the 5.8- and 8-micron channels to enhance the visibility of the dust features.

  16. Ready for the Cosmic Ball

    NASA Technical Reports Server (NTRS)

    2006-01-01

    Something appears to be peering through a shiny red mask, in this new false-colored image from NASA's Spitzer Space Telescope. The mysterious blue eyes are actually starlight from the cores of two merging galaxies, called NGC 2207 and IC 2163. The mask is the galaxies' dusty spiral arms.

    NGC 2207 and IC 2163 recently met and began a sort of gravitational tango about 40 million years ago. The two galaxies are tugging at each other, stimulating new stars to form. Eventually, this cosmic ball will come to an end, when the galaxies meld into one. The dancing duo is located 140 million light-years away in the Canis Major constellation.

    The Spitzer image reveals that the galactic mask is adorned with strings of pearl-like beads. These dusty clusters of newborn stars, called 'beads on a string' by astronomers, appear as white balls throughout the arms of both galaxies. They were formed when the galaxies first interacted, forcing dust and gas to clump together into colonies of stars.

    This type of beading has been seen before in other galaxies, but it took Spitzer's infrared eyes to identify them in NGC 2207 and IC 2163. Spitzer was able to see the beads because the stars inside heat up surrounding dust, which then radiates with infrared light.

    The biggest bead lighting up the left side of the mask is also the densest. In fact, some of its central stars might have merged to form a black hole. (Now, that would be quite the Mardi Gras mask!)

    This picture, taken by Spitzer's infrared array camera, is a four-channel composite. It shows light with wavelengths of 3.6 microns (blue); 4.5 microns (green); and 5.8 and 8.0 microns (red). The contribution from starlight (measured at 3.6 microns) has been subtracted from the 5.8- and 8-micron channels to enhance the visibility of the dust features.

  17. Sutureless aortic valve replacement

    PubMed Central

    Phan, Kevin

    2015-01-01

    The increasing incidence of aortic stenosis and greater co-morbidities and risk profiles of the contemporary patient population has driven the development of minimally invasive aortic valve surgery and percutaneous transcatheter aortic valve implantation (TAVI) techniques to reduce surgical trauma. Recent technological developments have led to an alternative minimally invasive option which avoids the placement and tying of sutures, known as “sutureless” or rapid deployment aortic valves. Potential advantages for sutureless aortic prostheses include reducing cross-clamp and cardiopulmonary bypass (CPB) duration, facilitating minimally invasive surgery and complex cardiac interventions, whilst maintaining satisfactory hemodynamic outcomes and low paravalvular leak rates. However, given its recent developments, the majority of evidence regarding sutureless aortic valve replacement (SU-AVR) is limited to observational studies and there is a paucity of adequately-powered randomized studies. Recently, the International Valvular Surgery Study Group (IVSSG) has formulated to conduct the Sutureless Projects, set to be the largest international collaborative group to investigate this technology. This keynote lecture will overview the use, the potential advantages, the caveats, and current evidence of sutureless and rapid deployment aortic valve replacement (AVR). PMID:25870807

  18. 81. View of 41 valve house (right) and 42 valve ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    81. View of 4-1 valve house (right) and 4-2 valve house (left); in the foreground is penstock which extends from Penstock No. 1 to the 4-1 valve house; looking south. Photo by Jet Lowe, HAER, 1989. - Puget Sound Power & Light Company, White River Hydroelectric Project, 600 North River Avenue, Dieringer, Pierce County, WA

  19. 83. Interior of 42 valve house; the motor and valve ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    83. Interior of 4-2 valve house; the motor and valve mechanism is identical to that in the 4-1 valve house. Photo by Jet Lowe, HAER, 1989. - Puget Sound Power & Light Company, White River Hydroelectric Project, 600 North River Avenue, Dieringer, Pierce County, WA

  20. Aortic valve replacement with the De Bakey valve.

    PubMed

    Paton, B C; Pine, M B

    1976-10-01

    De Bakey prostheses were inserted in 29 patients with aortic valve disease between October, 1970, and May, 1972. Ten patients have died, but all but one of the remaining 19 have beel followed for a minimum of 19 months. Evaluation of the results in these subjects indicates that the function of the De Bakey valve compares favorably with that of other aortic valve prostheses.

  1. Aortic valve surgery - minimally invasive

    MedlinePlus

    ... of the heart is reduced. This is called aortic stenosis. The aortic valve can be replaced using: Minimally ... RN, Wang A. Percutaneous heart valve replacement for aortic stenosis: state of the evidence. Ann Intern Med . 2010; ...

  2. Medications for Heart Valve Symptoms

    MedlinePlus

    ... Peripheral Artery Disease Venous Thromboembolism Aortic Aneurysm More Medications for Heart Valve Symptoms Updated:Sep 21,2016 How do medications help people with valve problems? People who are ...

  3. Locking apparatus for gate valves

    DOEpatents

    Fabyan, J.; Williams, C.W.

    A locking apparatus for fluid operated valves having a piston connected to the valve actuator which moves in response to applied pressure within a cylinder housing having a cylinder head, a catch block is secured to the piston, and the cylinder head incorporates a catch pin. Pressure applied to the cylinder to open the valve moves the piston adjacent to the cylinder head where the catch pin automatically engages the catch block preventing further movement of the piston or premature closure of the valve. Application of pressure to the cylinder to close the valve, retracts the catch pin, allowing the valve to close. Included are one or more selector valves, for selecting pressure application to other apparatus depending on the gate valve position, open or closed, protecting such apparatus from damage due to premature closing caused by pressure loss or operational error.

  4. Locking apparatus for gate valves

    DOEpatents

    Fabyan, Joseph; Williams, Carl W.

    1988-01-01

    A locking apparatus for fluid operated valves having a piston connected to the valve actuator which moves in response to applied pressure within a cylinder housing having a cylinder head, a catch block is secured to the piston, and the cylinder head incorporates a catch pin. Pressure applied to the cylinder to open the valve moves the piston adjacent to the cylinder head where the catch pin automatically engages the catch block preventing futher movement of the piston or premature closure of the valve. Application of pressure to the cylinder to close the valve, retracts the catch pin, allowing the valve to close. Included are one or more selector valves, for selecting pressure application to other apparatus depending on the gate valve position, open or closed, protecting such apparatus from damage due to premature closing caused by pressure loss or operational error.

  5. What Is Mitral Valve Prolapse?

    MedlinePlus

    ... may not close tightly. These flaps normally help seal or open the valve. Much of the time, ... and tricuspid valves close. They form a tight seal that prevents blood from flowing back into the ...

  6. Diseases of the Tricuspid Valve

    MedlinePlus

    ... diseases of the tricuspid valve are regurgitation and stenosis. Tricuspid Regurgitation Tricuspid regurgitation is also called tricuspid ... the tricuspid valve may also be needed. Tricuspid Stenosis Tricuspid stenosis is a narrowing or blockage of ...

  7. What Causes Heart Valve Disease?

    MedlinePlus

    ... this page from the NHLBI on Twitter. What Causes Heart Valve Disease? Heart conditions and other disorders, age-related changes, rheumatic fever, or infections can cause acquired heart valve disease. These factors change the ...

  8. Dolphin underwater bait-balling behaviors in relation to group and prey ball sizes.

    PubMed

    Vaughn-Hirshorn, Robin L; Muzi, Elisa; Richardson, Jessica L; Fox, Gabriella J; Hansen, Lauren N; Salley, Alyce M; Dudzinski, Kathleen M; Würsig, Bernd

    2013-09-01

    We characterized dusky dolphin (Lagenorhynchus obscurus) feeding behaviors recorded on underwater video, and related behaviors to variation in prey ball sizes, dolphin group sizes, and study site (Argentina versus New Zealand, NZ). Herding behaviors most often involved dolphins swimming around the side or under prey balls, but dolphins in Argentina more often swam under prey balls (48% of passes) than did dolphins in NZ (34% of passes). This result may have been due to differences in group sizes between sites, since groups are larger in Argentina. Additionally, in NZ, group size was positively correlated with proportion of passes that occurred under prey balls (p<0.001). Prey-capture attempts most often involved capturing fish from the side of prey balls, but dolphins in Argentina more often swam through prey balls (8% of attempts) than did dolphins in NZ (4% of attempts). This result may have been due to differences in prey ball sizes between sites, since dolphins fed on larger prey balls in Argentina (>74m(2)) than in NZ (maximum 33m(2)). Additionally, in NZ, dolphins were more likely to swim through prey balls to capture fish when they fed on larger prey balls (p=0.025). Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Hydrogen gas relief valve

    DOEpatents

    Whittlesey, Curtis C.

    1985-01-01

    An improved battery stack design for an electrochemical system having at least one cell from which a gas is generated and an electrolyte in communication with the cell is described. The improved battery stack design features means for defining a substantially closed compartment for containing the battery cells and at least a portion of the electrolyte for the system, and means in association with the compartment means for selectively venting gas from the interior of the compartment means in response to the level of the electrolyte within the compartment means. The venting means includes a relief valve having a float member which is actuated in response to the level of the electrolyte within the compartment means. This float member is adapted to close the relief valve when the level of the electrolyte is above a predetermined level and open the relief valve when the level of electrolyte is below this predetermined level.

  10. Magnetostrictive valve assembly

    NASA Technical Reports Server (NTRS)

    Richard, James A. (Inventor)

    2008-01-01

    A magnetostrictive valve assembly includes a housing that defines a passage with a seat being formed therein. A magnetically-biased and axially-compressed magnetostrictive assembly slidingly fitted in the passage is configured as a hollow and open-ended conduit adapted to support a flow of a fluid therethrough. Current-carrying coil(s) disposed about the passage in the region of the magnetostrictive assembly generate a magnetic field in the passage when current flows through the coil(s). A hollow valve body with side ports is coupled on one end thereof to an axial end of the magnetostrictive assembly. The other end of the valve body is designed to seal with the seat formed in the housing's passage when brought into contact therewith.

  11. Josephson magnetic rotary valve

    SciTech Connect

    Soloviev, I. I.; Klenov, N. V.; Bakurskiy, S. V.; Bol'ginov, V. V.; Ryazanov, V. V.; Kupriyanov, M. Yu.; Golubov, A. A.

    2014-12-15

    We propose a control element for a Josephson spin valve. It is a complex Josephson device containing ferromagnetic (F) layer in the weak-link area consisting of two regions, representing 0 and π Josephson junctions, respectively. The valve's state is defined by mutual orientations of the F-layer magnetization vector and boundary line between 0 and π sections of the device. We consider possible implementation of the control element by introduction of a thin normal metal layer in a part of the device area. By means of theoretical simulations, we study properties of the valve's structure as well as its operation, revealing such advantages as simplicity of control, high characteristic frequency, and good legibility of the basic states.

  12. Sliding valve pump

    SciTech Connect

    Rupert, C.L.

    1980-09-09

    A sliding valve pump for oil wells which includes a working barrel having a plurality of apertures located in spaced relationship in the wall thereof and a pair of travelling valves fitted within the working barrel and carried by a plunger rod, the valves also having a plurality of apertures or ports for periodic registration with the ports in the working barrel wall to facilitate pumping of fluid from an oil reservoir or pool to the surface. The pump is designed to pull the oil-gas mixture from the reservoir pool into the lower section of the working barrel on the downward stroke, and to subsequently pump the collected oil through the barrel and tubing upwardly toward the surface on the upward stroke.

  13. Variable Valve Actuation

    SciTech Connect

    Jeffrey Gutterman; A. J. Lasley

    2008-08-31

    Many approaches exist to enable advanced mode, low temperature combustion systems for diesel engines - such as premixed charge compression ignition (PCCI), Homogeneous Charge Compression Ignition (HCCI) or other HCCI-like combustion modes. The fuel properties and the quantity, distribution and temperature profile of air, fuel and residual fraction in the cylinder can have a marked effect on the heat release rate and combustion phasing. Figure 1 shows that a systems approach is required for HCCI-like combustion. While the exact requirements remain unclear (and will vary depending on fuel, engine size and application), some form of substantially variable valve actuation is a likely element in such a system. Variable valve actuation, for both intake and exhaust valve events, is a potent tool for controlling the parameters that are critical to HCCI-like combustion and expanding its operational range. Additionally, VVA can be used to optimize the combustion process as well as exhaust temperatures and impact the after treatment system requirements and its associated cost. Delphi Corporation has major manufacturing and product development and applied R&D expertise in the valve train area. Historical R&D experience includes the development of fully variable electro-hydraulic valve train on research engines as well as several generations of mechanical VVA for gasoline systems. This experience has enabled us to evaluate various implementations and determine the strengths and weaknesses of each. While a fully variable electro-hydraulic valve train system might be the 'ideal' solution technically for maximum flexibility in the timing and control of the valve events, its complexity, associated costs, and high power consumption make its implementation on low cost high volume applications unlikely. Conversely, a simple mechanical system might be a low cost solution but not deliver the flexibility required for HCCI operation. After modeling more than 200 variations of the

  14. Valve-spring Surge

    NASA Technical Reports Server (NTRS)

    Marti, Willy

    1937-01-01

    Test equipment is described that includes a system of three quartz indicators whereby three different pressures could be synchronized and simultaneously recorded on a single oscillogram. This equipment was used to test the reliction of waves at ends of valve spring, the dynamical stress of the valve spring for a single lift of the valve, and measurement of the curve of the cam tested. Other tests included simultaneous recording of the stress at both ends of the spring, spring oscillation during a single lift as a function of speed, computation of amplitude of oscillation for a single lift by harmonic analysis, effect of cam profile, the setting up of resonance, and forced spring oscillation with damping.

  15. Cricket Ball Aerodynamics: Myth Versus Science

    NASA Technical Reports Server (NTRS)

    Mehta, Rabindra D.; Koga, Demmis J. (Technical Monitor)

    2000-01-01

    Aerodynamics plays a prominent role in the flight of a cricket ball released by a bowler. The main interest is in the fact that the ball can follow a curved flight path that is not always under the control of the bowler. ne basic aerodynamic principles responsible for the nonlinear flight or "swing" of a cricket ball were identified several years ago and many papers have been published on the subject. In the last 20 years or so, several experimental investigations have been conducted on cricket ball swing, which revealed the amount of attainable swing, and the parameters that affect it. A general overview of these findings is presented with emphasis on the concept of late swing and the effects of meteorological conditions on swing. In addition, the relatively new concept of "reverse" swing, how it can be achieved in practice and the role in it of ball "tampering", are discussed in detail. A discussion of the "white" cricket ball used in last year's World Cup, which supposedly possesses different swing properties compared to a conventional red ball, is also presented.

  16. Numerical simulation of ball-racket impact

    NASA Astrophysics Data System (ADS)

    Yu, Yingpang

    The collision of a ball with a tennis racket is usually modeled in terms of rigid body dynamics or an elastic system involving only a few springs. In this paper, we study the impact between a tennis ball and racket, by modeling the tennis ball in two different yaws. One method models the tennis ball as a Hertz elastic body and the other one models the ball by a more accurate finite element analysis. In the first model, we assume that the elastic properties of the ball obeys Hertz's law. In the finite element model, we consider the tennis ball as a shell witch is a elastic system constructed out of many isotropic small linear flat, elements, witch have both elastic and damping properties. The damping in each way is approximated as viscous term. In both methods, we study the static condition of deformation against a rigid surface before applying these models to dynamical processes. We compare these two methods and eventually determine how the racket parameters effect the performance of the racket, using numerical simulations. Comparison with experiment are show to confirm the general conclusion of the model.

  17. Viscoelastic modelling of tennis ball properties

    NASA Astrophysics Data System (ADS)

    Sissler, L.; Jones, R.; Leaney, P. G.; Harland, A.

    2010-06-01

    An explicit finite element (FE) tennis ball model which illustrates the effects of the viscoelastic materials of a tennis ball on ball deformation and bounce during normal impacts is presented. A tennis ball is composed of a rubber core and a fabric cover comprised of a wool-nylon mix which exhibit non-linear strain rate properties during high velocity impacts. The rubber core model was developed and validated using low strain rate tensile tests on rubber samples as well as high velocity normal impacts of pressurised cores at velocities ranging from 15 m/s to 50 m/s. The impacts were recorded using a high speed video (HSV) camera to determine deformation, impact time and coefficient of restitution (COR). The material properties of the core model were tuned to match the HSV results. A two component anisotropic fabric model was created which included artificial Rayleigh damping to account for hysteresis effects, and the core model 'tuning' process was used to refine the cloth layer. The ball model's parameters were in good agreement with experimental data at all velocities for both cores and complete balls, and a time sequenced comparison of HSV ball motion and FE model confirmed the validity of the model.

  18. Examination of deposits in cerebrospinal fluid shunt valves using scanning electron microscopy.

    PubMed

    Charalambides, Constantinos; Sgouros, Spyros

    2012-01-01

    Obstruction remains the most common complication of cerebrospinal fluid shunts. The valve constitutes an important site of potential malfunction. The aim of this pilot study was to investigate the extent and composition of debris depositions along the structural components of the shunt valve.We examined three explanted Medos programmable valves. The valves were stored and examined wet. They were cut open and disassembled. All specimens were studied under a scanning electron microscope (SEM; Quanta 200; FEI, Hillsboro, OR, USA) operating at different levels of accelerating voltage and 110 μA beam current. Valve areas analyzed included the ruby ball and collar, the flat spring with its pillar, and the staircase cam. The elemental composition, in areas with abnormal deposits, was subsequently determined by energy-dispersive X-ray microanalysis (EDS) using a Si (Li) detector (Sapphire; EDAX, Mahwah, NJ, USA) with a super ultrathin Be window.All explanted valves had varying degrees of deposits in all surveyed areas. The extent of the deposits was not related to the time since implantation. The effect of these deposits on proper functioning of the valve as well as their pathogenesis is difficult to establish.

  19. Valve thrombosis following transcatheter aortic valve implantation: a systematic review.

    PubMed

    Córdoba-Soriano, Juan G; Puri, Rishi; Amat-Santos, Ignacio; Ribeiro, Henrique B; Abdul-Jawad Altisent, Omar; del Trigo, María; Paradis, Jean-Michel; Dumont, Eric; Urena, Marina; Rodés-Cabau, Josep

    2015-03-01

    Despite the rapid global uptake of transcatheter aortic valve implantation, valve trombosis has yet to be systematically evaluated in this field. The aim of this study was to determine the clinical characteristics, diagnostic criteria, and treatment outcomes of patients diagnosed with valve thrombosis following transcatheter aortic valve implantation through a systematic review of published data. Literature published between 2002 and 2012 on valve thrombosis as a complication of transcatheter aortic valve implantation was identified through a systematic electronic search. A total of 11 publications were identified, describing 16 patients (mean age, 80 [5] years, 65% men). All but 1 patient (94%) received a balloon-expandable valve. All patients received dual antiplatelet therapy immediately following the procedure and continued to take either mono- or dual antiplatelet therapy at the time of valve thrombosis diagnosis. Valve thrombosis was diagnosed at a median of 6 months post-procedure, with progressive dyspnea being the most common symptom. A significant increase in transvalvular gradient (from 10 [4] to 40 [12] mmHg) was the most common echocardiographic feature, in addition to leaflet thickening. Thrombus was not directly visualized with echocardiography. Three patients underwent valve explantation, and the remaining received warfarin, which effectively restored the mean transvalvular gradient to baseline within 2 months. Systemic embolism was not a feature of valve thrombosis post-transcatheter aortic valve implantation. Although a rare, yet likely under-reported complication of post-transcatheter aortic valve implantation, progressive dyspnea coupled with an increasing transvalvular gradient on echocardiography within the months following the intervention likely signifies valve thrombosis. While direct thrombus visualization appears difficult, prompt initiation of oral anticoagulation therapy effectively restores baseline valve function. Copyright © 2014

  20. Self-regulating valve

    DOEpatents

    Humphreys, D.A.

    1982-07-20

    A variable, self-regulating valve having a hydraulic loss coefficient proportional to a positive exponential power of the flow rate. The device includes two objects in a flow channel and structure which assures that the distance between the two objects is an increasing function of the flow rate. The range of spacing between the objects is such that the hydraulic resistance of the valve is an increasing function of the distance between the two objects so that the desired hydraulic loss coefficient as a function of flow rate is obtained without variation in the flow area.

  1. Pulsatile prosthetic valve flows.

    PubMed

    Phillips, W M; Snyder, A; Alchas, P; Rosenberg, G; Pierce, W S

    1980-01-01

    The laser Doppler system has been established as a useful tool for eliciting the properties of simulated cardiovascular flows, and thus for comparative studies of flow properties of prosthetic valves. Significant differences among valve types and between models of one type have been documented. The complex variations of velocity profiles with time show that comparisons must be made for unsteady pulsatile rather than steady flow, despite the volume and complexity of the data required. Future studies will include methods of compacting the data presentation and improving the details of the experimental stimulation.

  2. Lipomatous hamartoma of mitral valve.

    PubMed

    Bhat, Seetharama P S; Gowda, Girish S L; Chikkatur, Raghavendra; Nanjappa, Manjunath C

    2016-01-01

    Primary cardiac tumors are very rare, and tumors arising from cardiac valves are extremely rare. We present a case of lipomatous hamartoma of the mitral valve in a young female. This is the 6th case of lipomatous hamartoma of the mitral valve to be reported. We discuss the operative and histopathological findings.

  3. Lightweight Valve Closes Duct Quickly

    NASA Technical Reports Server (NTRS)

    Fournier, Walter L.; Burgy, N. Frank

    1991-01-01

    Expanding balloon serves as lightweight emergency valve to close wide duct. Uninflated balloon stored in housing of duct. Pad resting on burst diaphragm protects balloon from hot gases in duct. Once control system triggers valve, balloon inflates rapidly to block duct. Weighs much less than does conventional butterfly, hot-gas, or poppet valve capable of closing duct of equal diameter.

  4. Lightweight Valve Closes Duct Quickly

    NASA Technical Reports Server (NTRS)

    Fournier, Walter L.; Burgy, N. Frank

    1991-01-01

    Expanding balloon serves as lightweight emergency valve to close wide duct. Uninflated balloon stored in housing of duct. Pad resting on burst diaphragm protects balloon from hot gases in duct. Once control system triggers valve, balloon inflates rapidly to block duct. Weighs much less than does conventional butterfly, hot-gas, or poppet valve capable of closing duct of equal diameter.

  5. Valve stem and packing assembly

    DOEpatents

    Wordin, John J.

    1991-01-01

    A valve stem and packing assembly is provided in which a rotatable valve stem includes a first tractrix surface for sliding contact with a stem packing and also includes a second tractrix surface for sliding contact with a bonnet. Force is applied by means of a spring, gland flange, and gland on the stem packing so the stem packing seals to the valve stem and bonnet. This configuration serves to create and maintain a reliable seal between the stem packing and the valve stem. The bonnet includes a second complementary tractrix surface for contacting the second sliding tractrix surface, the combination serving as a journal bearing for the entire valve stem and packing assembly. The journal bearing so configured is known as a Schiele's pivot. The Schiele's pivot also serves to maintain proper alignment of the valve stem with respect to the bonnet. Vertical wear between the surfaces of the Schiele's pivot is uniform at all points of contact between the second sliding tractrix surface and the second complementary tractrix surface of a bonnet. The valve stem is connected to a valve plug by means of a slip joint. The valve is opened and closed by rotating the valve stem. The slip joint compensates for wear on the Schiele's pivot and on the valve plug. A ledge is provided on the valve bonnet for the retaining nut to bear against. The ledge prevents overtightening of the retaining nut and the resulting excessive friction between stem and stem packing.

  6. Valve stem and packing assembly

    DOEpatents

    Wordin, J.J.

    1991-09-03

    A valve stem and packing assembly is provided in which a rotatable valve stem includes a first tractrix surface for sliding contact with a stem packing and also includes a second tractrix surface for sliding contact with a bonnet. Force is applied by means of a spring, gland flange, and gland on the stem packing so the stem packing seals to the valve stem and bonnet. This configuration serves to create and maintain a reliable seal between the stem packing and the valve stem. The bonnet includes a second complementary tractrix surface for contacting the second sliding tractrix surface, the combination serving as a journal bearing for the entire valve stem and packing assembly. The journal bearing so configured is known as a Schiele's pivot. The Schiele's pivot also serves to maintain proper alignment of the valve stem with respect to the bonnet. Vertical wear between the surfaces of the Schiele's pivot is uniform at all points of contact between the second sliding tractrix surface and the second complementary tractrix surface of a bonnet. The valve stem is connected to a valve plug by means of a slip joint. The valve is opened and closed by rotating the valve stem. The slip joint compensates for wear on the Schiele's pivot and on the valve plug. A ledge is provided on the valve bonnet for the retaining nut to bear against. The ledge prevents over tightening of the retaining nut and the resulting excessive friction between stem and stem packing. 2 figures.

  7. Trajectory analysis of a soccer ball

    NASA Astrophysics Data System (ADS)

    Goff, John Eric; Carré, Matt J.

    2009-11-01

    We performed experiments in which a soccer ball was launched from a machine while two cameras recorded portions of its trajectory. Drag coefficients were obtained from range measurements for no-spin trajectories, for which the drag coefficient does not vary appreciably during the ball's flight. Lift coefficients were obtained from the trajectories immediately following the ball's launch, in which Reynolds number and spin parameter do not vary much. We obtain two values of the lift coefficient for spin parameters that had not been obtained previously. Our codes for analyzing the trajectories are freely available to educators and students.

  8. Craniofacial Reconstruction Using Rational Cubic Ball Curves

    PubMed Central

    Majeed, Abdul; Mt Piah, Abd Rahni; Gobithaasan, R. U.; Yahya, Zainor Ridzuan

    2015-01-01

    This paper proposes the reconstruction of craniofacial fracture using rational cubic Ball curve. The idea of choosing Ball curve is based on its robustness of computing efficiency over Bezier curve. The main steps are conversion of Digital Imaging and Communications in Medicine (Dicom) images to binary images, boundary extraction and corner point detection, Ball curve fitting with genetic algorithm and final solution conversion to Dicom format. The last section illustrates a real case of craniofacial reconstruction using the proposed method which clearly indicates the applicability of this method. A Graphical User Interface (GUI) has also been developed for practical application. PMID:25880632

  9. Rotating boson stars and Q-balls

    SciTech Connect

    Kleihaus, Burkhard; Kunz, Jutta; List, Meike

    2005-09-15

    We consider axially symmetric, rotating boson stars. Their flat-space limits represent spinning Q-balls. We discuss their properties and determine their domain of existence. Q-balls and boson stars are stationary solutions and exist only in a limited frequency range. The coupling to gravity gives rise to a spiral-like frequency dependence of the boson stars. We address the flat-space limit and the limit of strong gravitational coupling. For comparison we also determine the properties of spherically symmetric Q-balls and boson stars.

  10. Horizontal stability of a bouncing ball.

    PubMed

    McBennett, Brendan G; Harris, Daniel M

    2016-09-01

    We present an investigation of a partially elastic ball bouncing on a vertically vibrated concave parabolic surface in two dimensions. In particular, we demonstrate that simple vertical motion, wherein the ball bounces periodically at the parabola's vertex, is unstable to horizontal perturbations when the parabolic coefficient defining the surface shape exceeds a critical value. The result is a new periodic solution where the ball bounces laterally over the vertex. As the parabola is further steepened, this new solution also becomes unstable which gives rise to other complex periodic and chaotic bouncing states, all characterized by persistent lateral motion.

  11. Rediscovery of lake balls in Lake Michigan

    USGS Publications Warehouse

    Schloesser, Donald W.; Hiltunen, Jarl K.; Owens, Randall W.

    1983-01-01

    For the first time in 70 years, the occurrence of a 'lake ball' in Lake Michigan is here reported in the literature. According to a published system of classification, the object we collected in 1978 was a 'false' lake ball. Dissection revealed that it was colonized by 5 chironomid larvae and 162 oligochaetes. The species and numerical proportions of the oligochaetes indicated that it was formed in or near the mouth of a eutrophic tributary rather than in the open waters of Lake Michigan where it was found. Because of their mobility, false lake balls may be ecologically important, serving as natural vehicles for the dispersal of invertebrates.

  12. Designing Hollow Nano Gold Golf Balls

    PubMed Central

    2015-01-01

    Hollow/porous nanoparticles, including nanocarriers, nanoshells, and mesoporous materials have applications in catalysis, photonics, biosensing, and delivery of theranostic agents. Using a hierarchical template synthesis scheme, we have synthesized a nanocarrier mimicking a golf ball, consisting of (i) solid silica core with a pitted gold surface and (ii) a hollow/porous gold shell without silica. The template consisted of 100 nm polystyrene beads attached to a larger silica core. Selective gold plating of the core followed by removal of the polystyrene beads produced a golf ball-like nanostructure with 100 nm pits. Dissolution of the silica core produced a hollow/porous golf ball-like nanostructure. PMID:24937196

  13. Shock-Absorbent Ball-Screw Mechanism

    NASA Technical Reports Server (NTRS)

    Hirr, Otto A., Jr.; Meneely, R. W.

    1986-01-01

    Actuator containing two ball screws in series employs Belleville springs to reduce impact loads, thereby increasing life expectancy. New application of springs increases reliability of equipment in which ball screws commonly used. Set of three springs within lower screw of ball-screw mechanism absorbs impacts that result when parts reach their upper and lower limits of movement. Mechanism designed with Belleville springs as shock-absorbing elements because springs have good energy-to-volume ratio and easily stacked to attain any stiffness and travel.

  14. Shock-Absorbent Ball-Screw Mechanism

    NASA Technical Reports Server (NTRS)

    Hirr, Otto A., Jr.; Meneely, R. W.

    1986-01-01

    Actuator containing two ball screws in series employs Belleville springs to reduce impact loads, thereby increasing life expectancy. New application of springs increases reliability of equipment in which ball screws commonly used. Set of three springs within lower screw of ball-screw mechanism absorbs impacts that result when parts reach their upper and lower limits of movement. Mechanism designed with Belleville springs as shock-absorbing elements because springs have good energy-to-volume ratio and easily stacked to attain any stiffness and travel.

  15. Designing hollow nano gold golf balls.

    PubMed

    Landon, Preston B; Mo, Alexander H; Zhang, Chen; Emerson, Chris D; Printz, Adam D; Gomez, Alan F; DeLaTorre, Christopher J; Colburn, David A M; Anzenberg, Paula; Eliceiri, Matthew; O'Connell, Connor; Lal, Ratnesh

    2014-07-09

    Hollow/porous nanoparticles, including nanocarriers, nanoshells, and mesoporous materials have applications in catalysis, photonics, biosensing, and delivery of theranostic agents. Using a hierarchical template synthesis scheme, we have synthesized a nanocarrier mimicking a golf ball, consisting of (i) solid silica core with a pitted gold surface and (ii) a hollow/porous gold shell without silica. The template consisted of 100 nm polystyrene beads attached to a larger silica core. Selective gold plating of the core followed by removal of the polystyrene beads produced a golf ball-like nanostructure with 100 nm pits. Dissolution of the silica core produced a hollow/porous golf ball-like nanostructure.

  16. Titanium carbide coatings for aerospace ball bearings

    NASA Technical Reports Server (NTRS)

    Boving, Hans J.; Haenni, Werner; Hintermann, HANS-E.

    1988-01-01

    In conventional ball bearings, steel to steel contacts between the balls and the raceways are at the origin of microwelds which lead to material transfer, surface roughening, lubricant breakdown, and finally to a loss in the bearing performances. To minimize the microwelding tendencies of the contacting partners it is necessary to modify their surface materials; the solid to solid collisions themselves are difficult to avoid. The use of titanium carbide coated steel balls can bring spectacular improvements in the performances and lifetimes of both oil-grease lubricated and oil-grease free bearings in a series of severe applications.

  17. Transcatheter Valve-in-Valve: A Cautionary Tale.

    PubMed

    Luc, Jessica G Y; Shanks, Miriam; Tyrrell, Benjamin D; Welsh, Robert C; Butler, Craig R; Meyer, Steven R

    2016-09-01

    Transcatheter aortic valve replacement (TAVR) by valve-in-valve (VIV) implantation is an alternative treatment for high-risk patients with a degenerating aortic bioprosthesis. We present a case of transapical TAVR VIV with a 29-mm Edwards SAPIEN XT (ESV) (Edwards Lifesciences, Irvine, CA) into a 29-mm Medtronic Freestyle stentless bioprosthesis (Medtronic Inc, Minneapolis, MN) in which unanticipated dilatation of the Freestyle bioprosthesis resulted in intraprocedural embolization of the TAVR valve, necessitating urgent conversion to a conventional surgical aortic valve replacement (AVR). Our experience suggests that TAVR VIV with the 29-mm ESV in the setting of a degenerated 29-mm Freestyle stentless bioprosthesis must be undertaken with caution.

  18. Production of ball-lightning-like luminous balls by electrical discharges in silicon.

    PubMed

    Paiva, Gerson Silva; Pavão, Antonio Carlos; Alpes de Vasconcelos, Elder; Mendes, Odim; da Silva, Eronides Felisberto

    2007-01-26

    We performed electric arc discharges in pure Si to generate luminous balls with lifetime in the order of seconds and several properties usually reported for natural ball lightning. This simple experiment does not rely on energy sources and excitation mechanisms that are improbable in the natural phenomenon and clearly demonstrates the role of vaporization and oxidation of Si, as proposed by the Abrahamson-Dinniss theory for ball-lightning formation.

  19. How Magnus Bends the Flying Ball--Experimenting and Modeling

    ERIC Educational Resources Information Center

    Timková, V.; Ješková, Z.

    2017-01-01

    Students are well aware of the effect of the deflection of sports balls when they have been given a spin. A volleyball, tennis, or table tennis ball served with topspin results in an additional downward force that makes the ball difficult to catch and return. In soccer, the effect of sidespin causes the ball to curve unexpectedly sideways,…

  20. Thermostatic Radiator Valve Evaluation

    SciTech Connect

    Dentz, Jordan; Ansanelli, Eric

    2015-01-01

    A large stock of multifamily buildings in the Northeast and Midwest are heated by steam distribution systems. Losses from these systems are typically high and a significant number of apartments are overheated much of the time. Thermostatically controlled radiator valves (TRVs) are one potential strategy to combat this problem, but have not been widely accepted by the residential retrofit market.

  1. Transcatheter aortic valve replacement

    MedlinePlus

    ... fully will restrict blood flow. This is called aortic stenosis. If there is also a leak, it is ... TAVR is used for people with severe aortic stenosis who aren't ... valve . In adults, aortic stenosis usually occurs due to calcium ...

  2. Valve for gas centrifuges

    DOEpatents

    Hahs, C.A.; Rurbage, C.H.

    1982-03-17

    The invention is pneumatically operated valve assembly for simulatenously (1) closing gas-transfer lines connected to a gas centrifuge or the like and (2) establishing a recycle path between two on the lines so closed. The value assembly is especially designed to be compact, fast-acting, reliable, and comparatively inexpensive. It provides large reductions in capital costs for gas-centrifuge cascades.

  3. Mitral Valve Prolapse

    MedlinePlus

    ... Search By Zipcode Search by State SELECT YOUR LANGUAGE Español (Spanish) 简体中文 (Traditional Chinese) 繁体中文 (Simplified Chinese) ... Walk through a step-by-step interactive guide explaining your valve issue and treatment options with helpful ...

  4. Stennis tests shuttle valves

    NASA Image and Video Library

    2009-02-12

    Flames burst from the E-1 Test Stand as Stennis Space Center engineers perform one of dozens of shuttle flow valve tests in early February. Stennis engineers teamed with Innovative Partnership Program partners to perform the tests after NASA officials delayed the launch of the STS-119 mission because of concerns with the shuttle part.

  5. Stennis tests shuttle valves

    NASA Technical Reports Server (NTRS)

    2009-01-01

    Flames burst from the E-1 Test Stand as Stennis Space Center engineers perform one of dozens of shuttle flow valve tests in early February. Stennis engineers teamed with Innovative Partnership Program partners to perform the tests after NASA officials delayed the launch of the STS-119 mission because of concerns with the shuttle part.

  6. Poppet valve tester

    NASA Technical Reports Server (NTRS)

    Tellier, G. F.

    1973-01-01

    Tester investigates fundamental factors affecting cyclic life and sealing performance of valve seats and poppets. Tester provides for varying impact loading of poppet against seat and rate of cycling, and controls amount and type of relative motion between sealing faces of seat and poppet. Relative motion between seat and poppet can be varied in three modes.

  7. Valved molecular beam skimmer

    NASA Astrophysics Data System (ADS)

    Marceca, Ernesto; Becker, Jörg A.; Hensel, Friedrich

    1997-08-01

    Under routine source conditions, the optimum nozzle-skimmer distance to achieve maximum molecular beam intensities is within the range of a few millimeters. In cases where double skimming is additionally required, the distance between the skimmers should be kept small in order to sample a sufficiently large solid angle of the beam and hence maintain a good enough intensity. These two facts make it normally difficult to isolate the first from the second expansion chamber using a commercial vacuum gate valve due to the lack of remaining space. This note presents the design of a vacuum-tight valve which allows the aperture of a skimmer to be closed by plugging a needle directly against its internal conical wall. The valve can be driven manually or pneumatically from outside the vacuum chamber. The helium conductance of the valve was measured to be better than 1×10-8 mbar×l×s-1 for a helium partial pressure difference of 1 bar.

  8. Vent Relief Valve Test

    NASA Technical Reports Server (NTRS)

    2008-01-01

    Shown is the disassembly, examination, refurbishment and testing of the LH2 ( liquid hydrogen) and LOX (liquid oxygen) vent and relief valves for the S-IVB-211 engine stage in support of the Constellation/Ares project. This image is extracted from high definition video and is the highest resolution available.

  9. Valve for cryogenic service

    DOEpatents

    Worwetz, H.A.

    1975-09-02

    This patent relates to a valve for use with a liquefied gas at cryogenic temperatures in which a pair of joined knife edges are bellows controlled to contact an indium alloy seat in an annular slot when flow is to be stopped. The sealing alloy may be renewed by heating in situ. (auth)

  10. Improved Merge Valve

    NASA Technical Reports Server (NTRS)

    George-Falvy, Dez

    1992-01-01

    Circumferential design combines compactness and efficiency. In remotely controlled valve, flow in tributary duct along circumference of primary duct merged with flow in primary duct. Flow in tributary duct regulated by variable throat nuzzle driven by worm gear. Design leak-proof, and most components easily fabricated on lathe.

  11. TUBE SHEARING VALVE

    DOEpatents

    Wilner, L.B.

    1960-05-24

    Explosive operated valves can be used to join two or more containers in fluid flow relationship, one such container being a sealed reservoir. The valve is most simply disposed by mounting it on the reservoir so thst a tube extends from the interior of the reservoir through the valve body, terminating at the bottom of the bore in a closed end; other containers may be similarly connected or may be open connected, as desired. The piston of the valve has a cutting edge at its lower end which shears off the closed tube ends and a recess above the cutting edge to provide a flow channel. Intermixing of the fluid being transferred with the explosion gases is prevented by a copper ring at the top of the piston which is force fitted into the bore at the beginning of the stroke. Although designed to avoid backing up of the piston at pressures up to 10,000 psi in the transferred fluid, proper operation is independent of piston position, once the tube ends were sheared.

  12. Static Load Distribution in Ball Bearings

    NASA Technical Reports Server (NTRS)

    Ricci, Mario

    2010-01-01

    A numerical procedure for computing the internal loading distribution in statically loaded, single-row, angular-contact ball bearings when subjected to a known combined radial and thrust load is presented. The combined radial and thrust load must be applied in order to avoid tilting between inner and outer rings. The numerical procedure requires the iterative solution of Z + 2 simultaneous nonlinear equations - where Z is the number of the balls - to yield an exact solution for axial and radial deflections, and contact angles. Numerical results for a 218 angular-contact ball bearing have been compared with those from the literature and show significant differences in the magnitudes of the ball loads, contact angles, and the extent of the loading zone.

  13. Does soccer ball heading cause retinal bleeding?

    PubMed

    Reed, William F; Feldman, Kenneth W; Weiss, Avery H; Tencer, Alan F

    2002-04-01

    To define forces of youth soccer ball heading (headers) and determine whether heading causes retinal hemorrhage. Regional Children's Hospital, youth soccer camp. Male and female soccer players, 13 to 16 years old, who regularly head soccer balls. Dilated retinal examination, after 2-week header diary, and accelerometer measurement of heading a lofted soccer ball. Twenty-one youth soccer players, averaging 79 headers in the prior 2 weeks, and 3 players who did not submit header diaries lacked retinal hemorrhage. Thirty control subjects also lacked retinal hemorrhage. Seven subjects heading the ball experienced linear cranial accelerations of 3.7 +/- 1.3g. Rotational accelerations were negligible. Headers, not associated with globe impact, are unlikely to cause retinal hemorrhage. Correctly executed headers did not cause significant rotational acceleration of the head, but incorrectly executed headers might.

  14. Impact of a ping-pong ball

    NASA Astrophysics Data System (ADS)

    Cross, Rod

    2017-05-01

    Measurements are presented of the impact time, peak force and centre of mass displacement of a ping-pong ball impacting vertically on a hard, horizontal surface. The results are compared with a recent measurement described in this journal.

  15. Bouncing Balls and Hot Rod Races.

    ERIC Educational Resources Information Center

    Tibbs, Peggy; Sherrill, Donna

    This paper presents the Bouncing Ball Experiment which models quadratic and exponential functions, and the Hot Rod Races activity that explores velocity and acceleration. Activities include directions for the use of TI-82 and TI-83 calculators. (YDS)

  16. Contact Sensors on Ceramic Ball Bearings

    NASA Astrophysics Data System (ADS)

    Yi, Jia; Just-Agosto, Frederick; Romero, Edwar

    2002-01-01

    Integration of micro contact sensors onto a ball bearing is a critical technology necessary for on-line bearing health monitoring in an industrial harsh environment and evaluation of the bearing performance and design. The current planner fabrication methods offered by the MEMS technology restrict the possibility of integrating micro sensor onto a double contoured bearing surface in a more traditional manufacturing environment. We have developed an unique technique to directly fabricate micron-sized pressure and temperature sensors onto a miniature ceramic ball bearing. A complete fabrication process, based on sensor design, surface preparation, optimized sputtering parameters, photolithographic techniques and sensor post-treatment, is described. Pressure and temperature measurement results on a miniature ceramic ball bearing show good correlation with numerical thermal-EHL analysis and good wear resistance. Keywords: Ball Bearing, Thin film Sensor, Pressure sensor, Temperature Sensor, adhesion, wear resistance, Non-developable surface, and thermal-EHL.

  17. Acting Administrator Lightfoot Visits Ball Aerospace

    NASA Image and Video Library

    2017-04-06

    Acting NASA Administrator Robert Lightfoot, center, is seen during a visit to the environmental test facilities at Ball Aerospace, Thursday, April 6, 2017 in Boulder, Colo. Photo Credit: (NASA/Joel Kowsky)

  18. Reexamination of Ball-Race Conformity Effects on Ball Bearing Life

    NASA Technical Reports Server (NTRS)

    Zaretsky, Erwin V.; Poplawski, Joseph V.; Root, Lawrence E.

    2007-01-01

    The analysis in this report considers the life of the ball set as well as the respective lives of the races to reassess the effect of ball-race conformity on ball bearing life. The related changes in ball bearing life are incorporated in life factors that can be used to modify the bearing predicted life using the Lundberg-Palmgren equations and the ANSI/ABMA and ISO Standards. Two simple algebraic relationships were established to calculate life factors LF(sub c) to determine the effect of inner- and outer-race conformity combinations on bearing L(sub 10) life for deepgroove and angular-contact ball bearings, respectively. Depending on the bearing type and series as well as conformity combinations, the calculated life for deep-groove ball bearings can be over 40 percent less than that calculated by the Lundberg-Palmgren equations. For angular-contact ball bearings, the life can vary between +16 and -39 percent from that calculated by the Lundberg-Palmgren equations. Comparing the two ball bearing types, the life factors LF(sub c) for the deep-groove bearings can be as much as 40 percent lower than that for angular-contact ball bearings.

  19. Middle finger and ball movements around ball release during baseball fastball pitching.

    PubMed

    Matsuo, Tomoyuki; Jinji, Tsutomu; Hirayama, Daisaku; Nasu, Daiki; Ozaki, Hiroki; Kumagawa, Daisuke

    2017-02-28

    The objectives of this study were to investigate middle finger movements and dynamics of ball movements around the instant of ball release during baseball pitching. Baseball pitching from an indoor mound among 14 semi-professional pitchers was captured using a motion capture system with 16 high-speed cameras (1,000 Hz). Kinematics of middle finger joints, ball rotation, and force applied to the ball were calculated. The proximal and distal interphalangeal joints continued to extend until the instant of ball release, then abruptly flexed. The abrupt flexion lasted for only several milliseconds, followed by a short extension phase. The finger made a quick double cycle of extension-flexion movement, suggesting that it attained high stiffness resulting from co-contraction. The ball began to roll up to the tip of the finger 8 ± 1 ms before ball release owing to the start of extension or the increased angular velocity of extension for the proximal interphalangeal joint. A mean force of 195 ± 27 N was applied in the proximal direction of the hand at the same time as the beginning of ball rolling, and a mean force of 109 ± 22 N was applied to the throwing direction just before ball release.

  20. Valve assembly for internal combustion engine

    SciTech Connect

    Wakeman, R.J.; Shea, S.F.

    1989-09-05

    This patent describes an improvement in a valve assembly for an internal combustion engine of the type including a valve having a valve stem, a valve guideway for mounting this valve for reciprocal strokes between opened and seated position, and spring means for biasing the valve into the seated position. The improvement comprising a valve spool of greater cross-sectional diameter as compared to the valve stem, and a valve spool guideway within which the valve spool is movable during the strokes of the valve, an upper surface of the valve spool and a portion of the spool guideway collectively establishing a damper chamber which varies in volume during the valve strokes. a feed passage for introducing oil into the damper chamber, and a bleed passage for discharging oil from the damper chamber. The bleed passages each laterally opening into the valve spool guideway.

  1. Crystal ball single event display

    SciTech Connect

    Grosnick, D.; Gibson, A.; Allgower, C.; Alyea, J. |

    1997-10-15

    The Single Event Display (SED) is a routine that is designed to provide information graphically about a triggered event within the Crystal Ball. The SED is written entirely in FORTRAN and uses the CERN-based HICZ graphing package. The primary display shows the amount of energy deposited in each of the NaI crystals on a Mercator-like projection of the crystals. Ten different shades and colors correspond to varying amounts of energy deposited within a crystal. Information about energy clusters is displayed on the crystal map by outlining in red the thirteen (or twelve) crystals contained within a cluster and assigning each cluster a number. Additional information about energy clusters is provided in a series of boxes containing useful data about the energy distribution among the crystals within the cluster. Other information shown on the event display include the event trigger type and data about {pi}{sup o}`s and {eta}`s formed from pairs of clusters as found by the analyzer. A description of the major features is given, along with some information on how to install the SED into the analyzer.

  2. Multi-port valve assembly

    DOEpatents

    Guggenheim, S. Frederic

    1986-01-01

    A multi-port fluid valve apparatus is used to control the flow of fluids through a plurality of valves and includes a web, which preferably is a stainless steel endless belt. The belt has an aperture therethrough and is progressed, under motor drive and control, so that its aperture is moved from one valve mechanism to another. Each of the valve mechanisms comprises a pair of valve blocks which are held in fluid-tight relationship against the belt. Each valve block consists of a block having a bore through which the fluid flows, a first seal surrounding the bore and a second seal surrounding the first seal, with the distance between the first and second seals being greater than the size of the belt aperture. In order to open a valve, the motor progresses the belt aperture to where it is aligned with the two bores of a pair of valve blocks, such alignment permitting a flow of the fluid through the valve. The valve is closed by movement of the belt aperture and its replacement, within the pair of valve blocks, by a solid portion of the belt.

  3. Gravitational waves from Q-ball formation

    SciTech Connect

    Chiba, Takeshi; Kamada, Kohei; Yamaguchi, Masahide

    2010-04-15

    We study the detectability of the gravitational waves (GWs) from the Q-ball formation associated with the Affleck-Dine (AD) mechanism, taking into account both the dilution effects due to Q-ball domination and to finite temperature. The AD mechanism predicts the formation of nontopological solitons, Q-balls, from which GWs are generated. Q-balls with large conserved charge Q can produce a large amount of GWs. On the other hand, the decay rate of such Q-balls is so small that they may dominate the energy density of the Universe, which implies that GWs are significantly diluted and that their frequencies are redshifted during the Q-ball dominated era. Thus, the detectability of the GWs associated with the formation of Q-balls is determined by these two competing effects. We find that there is a finite but small parameter region where such GWs may be detected by future detectors such as DECIGO or BBO, only in the case when the thermal logarithmic potential dominates the potential of the AD field. Otherwise GWs from Q-balls would not be detectable even by these futuristic detectors: {Omega}{sub GW}{sup 0}<10{sup -21}. Unfortunately, for such parameter region the present baryon asymmetry of the Universe can hardly be explained unless one fine-tunes A-terms in the potential. However the detection of such a GW background may give us an information about the early Universe, for example, it may suggest that the flat directions with B-L=0 are favored.

  4. Fracture analysis of HPOTP bearing balls

    NASA Technical Reports Server (NTRS)

    Bhat, B. N.

    1981-01-01

    The fracture analysis conducted on four HPOTP (High Pressure Oxygen Turbopump) bearing balls from the SSME (Space Shuttle Main Engine) is described. Nondestructive evaluation, optical microscopy, and transmission microscopy techniques were used in the analysis. The cracks are initiated at or close to the ball surface under conditions of high cyclic stresses and high coefficient of friction. The cracks lead to spalls and subsequent crack propagation occurs by fatigue mode under concentrated loading of cyclic nature.

  5. Acting Administrator Lightfoot Visits Ball Aerospace

    NASA Image and Video Library

    2017-04-06

    Michael Dean, senior project engineer for the Joint Polar Satellite System (JPSS) program at Ball Aerospace, right, speaks with acting NASA Deputy Administrator Lesa Roe, second from left, and acting NASA Administrator Robert Lightfoot, center, about the 20ft. by 24 ft. vertical thermal vacuum chamber, Thursday, April 6, 2017 during a visit to Ball Aerospace in Boulder, Colo. Photo Credit: (NASA/Joel Kowsky)

  6. Fractal aggregates in tennis ball systems

    NASA Astrophysics Data System (ADS)

    Sabin, J.; Bandín, M.; Prieto, G.; Sarmiento, F.

    2009-09-01

    We present a new practical exercise to explain the mechanisms of aggregation of some colloids which are otherwise not easy to understand. We have used tennis balls to simulate, in a visual way, the aggregation of colloids under reaction-limited colloid aggregation (RLCA) and diffusion-limited colloid aggregation (DLCA) regimes. We have used the images of the cluster of balls, following Forrest and Witten's pioneering studies on the aggregation of smoke particles, to estimate their fractal dimension.

  7. Miniature Latching Valve

    NASA Technical Reports Server (NTRS)

    Johnson, A. David; Benson, Glendon M.

    2008-01-01

    A miniature latching valve has been invented to satisfy a need for an electrically controllable on/off pneumatic valve that is lightweight and compact and remains in the most recently commanded open or closed state when power is not supplied. The valve includes a poppet that is moved into or out of contact with a seat to effect closure or opening, respectively, of the flow path. Motion of the poppet is initiated by electrical heating of one of two opposing pairs of nickel/titanium shape-memory alloy (SMA) wires above their transition temperature: heated wires contract to their remembered length, applying tension to pull the poppet toward or away from the seat. A latch consisting mainly of a bistable Belleville washer (a conical spring) made of a hardened stainless steel operates between two stable positions corresponding to the fully closed or fully open state, holding the poppet in one of these positions when power is not applied to either pair of SMA wires. To obtain maximum actuation force and displacement, the SMA wires must be kept in tension. The mounting fixtures at the ends of the wires must support large tensile stresses without creating stress concentrations that would limit the fatigue lives of the wires. An earlier design provided for each wire to be crimped in a conical opening with a conical steel ferrule that was swaged into the opening to produce a large, uniformly distributed holding force. In a subsequent design, the conical ferrule was replaced with a larger crimped cylindrical ferrule depicted in the figure. A major problem in designing the valve was to protect the SMA wires from a bake-out temperature of 300 C. The problem was solved by incorporating the SMA wires into an actuator module that is inserted into a barrel of the valve body and is held in place by miniature clip rings.

  8. Hypoplasia of the aortic root 1

    PubMed Central

    Nicks, Rowan; Cartmill, T.; Bernstein, L.

    1970-01-01

    We report a technique for the enlargement of a hypoplastic aortic root by an operation whereby the hypoplastic aortic root has been so enlarged by the insertion of a Dacron fabric gusset that it will accommodate a size 9A or larger Starr-Edwards prosthesis. Our experience in five patients is described. No matter what type of valve is used for replacement of a diseased aortic valve, and no matter what improved designs of valvular prosthesis are ultimately developed, it will be necessary (in the particular group described) to enlarge the aortic ring to accommodate a size which will function correctly without causing left ventricular outflow obstruction. Images PMID:5452289

  9. Micro-valve pump light valve display

    DOEpatents

    Yeechun Lee.

    1993-01-19

    A flat panel display incorporates a plurality of micro-pump light valves (MLV's) to form pixels for recreating an image. Each MLV consists of a dielectric drop sandwiched between substrates, at least one of which is transparent, a holding electrode for maintaining the drop outside a viewing area, and a switching electrode from accelerating the drop from a location within the holding electrode to a location within the viewing area. The sustrates may further define non-wetting surface areas to create potential energy barriers to assist in controlling movement of the drop. The forces acting on the drop are quadratic in nature to provide a nonlinear response for increased image contrast. A crossed electrode structure can be used to activate the pixels whereby a large flat panel display is formed without active driver components at each pixel.

  10. Micro-valve pump light valve display

    DOEpatents

    Lee, Yee-Chun

    1993-01-01

    A flat panel display incorporates a plurality of micro-pump light valves (MLV's) to form pixels for recreating an image. Each MLV consists of a dielectric drop sandwiched between substrates, at least one of which is transparent, a holding electrode for maintaining the drop outside a viewing area, and a switching electrode from accelerating the drop from a location within the holding electrode to a location within the viewing area. The sustrates may further define non-wetting surface areas to create potential energy barriers to assist in controlling movement of the drop. The forces acting on the drop are quadratic in nature to provide a nonlinear response for increased image contrast. A crossed electrode structure can be used to activate the pixels whereby a large flat panel display is formed without active driver components at each pixel.

  11. The ball SITE sign: Ball sports-induced targetoid erythema in a racquetball player

    PubMed Central

    Cohen, Philip R.

    2015-01-01

    Background: Cutaneous injury following impact of a high velocity ball to the skin may result in either erythema or purpura or both. The lesion typically appears as an annular ring of erythema with or without accompanying ecchymosis when the skin is contacted by a paintball, a ping pong ball, a racquetball or a squash ball. Purpose: To describe a girl with targetoid erythema following impact of a racquetball on her flank and back and to review other sports associated with this response to skin injury. Methods: PubMed was used to search the following terms, separately and in combination: ball, erythema, paint, ping pong, purpura, racquetball, sign, site, sports, squash, targetoid. All papers were reviewed and relevant manuscripts, along with their reference citations, were evaluated. Results: A 13-year-old girl developed an annular red ring surrounding a central area of normal appearing skin on her right flank and upper back where a racquetball traveling at a high velocity contacted her skin. Similar appearing lesions of targetoid erythema have been described at the cutaneous impact sites of either paintballs, ping pong balls, squash balls; in addition to erythema, purpura may also concurrently appear or subsequently develop at the contact location of the ball with the skin. Conclusions: Targetoid erythema is a pathognomonic cutaneous presentation resulting from the impact of either a paintball, ping pong ball, racquetball or squash ball—that is traveling at a high velocity—with a sport participant’s skin. The ball SITE (sports-induced targetoid erythema) sign is suggested as a unifying nomenclature to designate this unique, ball sport-associated, cutaneous dermatosis in athletes participating in sports in which high velocity impact of the ball with the skin may occur. PMID:26336625

  12. Fast acting multiple element valve

    DOEpatents

    Yang, Jefferson Y. S.; Wada, James M.

    1991-01-01

    A plurality of slide valve elements having plural axial-spaced annular parts and an internal slide are inserted into a bulkhead in a fluid conduit from a downstream side of the bulkhead, locked in place by a bayonet coupling and set screw, and project through the bulkhead into the upstream conduit. Pneumatic lines connecting the slide valve element actuator to pilot valves are brought out the throat of the valve element to the downstream side. Pilot valves are radially spaced around the exterior of the valve to permit the pneumatic lines to be made identical, thereby to minimize adverse timing tolerances in operation due to pressure variations. Ring manifolds surround the valve adjacent respective pilot valve arrangements to further reduce adverse timing tolerances due to pressure variations, the manifolds being directly connected to the respective pilot valves. Position sensors are provided the valve element slides to signal the precise time at which a slide reaches or passes through a particular point in its stroke to initiate a calibrated timing function.

  13. Fast-acting valve and uses thereof

    DOEpatents

    Meyer, James A.

    1982-01-01

    A very fast acting valve capable of producing a very well-defined plug of gas suitable for filling a theta pinch vacuum vessel is given. The valve requires no springs, instead being stopped mainly by a nonlinear force. Thus, the valve is not subject to bouncing; and the ratio of the size of the valve housing to the size of the valve stem is smaller than it would be if springs were needed to stop the valve stem. Furthermore, the valve can be used for thousands of valve firings with no apparent valve damage.

  14. Fast-acting valve and uses thereof

    DOEpatents

    Meyer, J.A.

    1980-05-16

    A very fast acting valve capable of producing a very well-defined plug of gas suitable for filling a theta pinch vacuum vessel is given. The valve requires no springs, instead being stopped mainly by a nonlinear force. Thus, the valve is not subject to bouncing; and the ratio of the size of the valve housing to the size of the valve stem is smaller than it would be if springs were needed to stop the valve stem. Furthermore, the valve can be used for thousands of valve firings with no apparent valve damage.

  15. Ball to separator contact forces in angular contact ball bearings under thrust and radial loads

    NASA Technical Reports Server (NTRS)

    Nypan, L. J.

    1978-01-01

    Experimental data are reported on ball to cage contact forces in a 110 mm bore ball bearing operating at speeds to 12,000 rpm under radial and thrust loads. Information is also reported on cage to inner race land contact force, cage to inner race land clearance, and cage to shaft speed ratios.

  16. A comparative study of two types of ball-on-ball collision

    NASA Astrophysics Data System (ADS)

    White, Colin

    2017-07-01

    This paper describes three methods of measuring the coefficient of restitution (CoR) for two different types of ball-on-ball collision. The first collision type (for which two different CoR measurement procedures are described) is a static, hanging steel ball forming part of a Newton’s cradle arrangement, which is then hit by its adjacent identical ball, swinging down from an angle. The second scenario (for which one CoR measurement procedure is described) is a snooker ball interaction in which the cue ball rolls in, and collides with, a static coloured ball (both balls being of a resin composition). The investigation requires only readily available and inexpensive equipment, together with an open-source video analysis programme, called ‘Tracker’2. Perhaps surprisingly, the experiment yields widely differing CoR values for the two types of interaction. This variance cannot be solely accounted for by the difference in physical properties of the respective balls’ compositions. The paper then describes, in theoretical terms, the details of the dynamic interactions in each example, and hence validates the surprising discrepancy in the two results obtained empirically.

  17. Aerodynamic drag of modern soccer balls.

    PubMed

    Asai, Takeshi; Seo, Kazuya

    2013-12-01

    Soccer balls such as the Adidas Roteiro that have been used in soccer tournaments thus far had 32 pentagonal and hexagonal panels. Recently, the Adidas Teamgeist II and Adidas Jabulani, respectively having 14 and 8 panels, have been used at tournaments; the aerodynamic characteristics of these balls have not yet been verified. Now, the Adidas Tango 12, having 32 panels, has been developed for use at tournaments; therefore, it is necessary to understand its aerodynamic characteristics. Through a wind tunnel test and ball trajectory simulations, this study shows that the aerodynamic resistance of the new 32-panel soccer ball is larger in the high-speed region and lower in the middle-speed region than that of the previous 14- and 8-panel balls. The critical Reynolds number of the Roteiro, Teamgeist II, Jabulani, and Tango 12 was ~2.2 × 10(5) (drag coefficient, C d  ≈ 0.12), ~2.8 × 10(5) (C d  ≈ 0.13), ~3.3 × 10(5) (C d  ≈ 0.13), and ~2.4 × 10(5) (C d  ≈ 0.15), respectively. The flight trajectory simulation suggested that the Tango 12, one of the newest soccer balls, has less air resistance in the medium-speed region than the Jabulani and can thus easily acquire large initial velocity in this region. It is considered that the critical Reynolds number of a soccer ball, as considered within the scope of this experiment, depends on the extended total distance of the panel bonds rather than the small designs on the panel surfaces.

  18. Bioprosthetic mitral valve dysfunction due to native valve preserving procedure.

    PubMed

    Matsuno, Yukihiro; Mori, Yoshio; Umeda, Yukio; Takiya, Hiroshi

    2016-03-01

    Mitral valve replacement with preservation of the mitral leaflets and subvalvular apparatus is considered to maintain left ventricular geometry and function and reduce the risk of myocardial rupture. However, the routine use of this technique may lead to early complications such as left ventricular outflow tract obstruction and even mitral inflow obstruction, requiring reoperation. We describe a rare case of bioprosthetic mitral valve dysfunction caused by a native valve preserving procedure.

  19. Performance Characteristics of an Isothermal Freeze Valve

    SciTech Connect

    Hailey, A.E.

    2001-08-22

    This document discusses performance characteristics of an isothermal freeze valve. A freeze valve has been specified for draining the DWPF melter at the end of its lifetime. Two freeze valve designs have been evaluated on the Small Cylindrical Melter-2 (SCM-2). In order to size the DWPF freeze valve, the basic principles governing freeze valve behavior need to be identified and understood.

  20. Rotary multiposition valve

    DOEpatents

    Barclay, John A.; Dyson, Jack E.

    1985-01-01

    The disclosure is directed to a rotary multiposition valve for selectively directing the flow of a fluid through a plurality of paths. The valve comprises an inner member and a hollow housing with a row of ducts on its outer surface. The ducts are in fluid communication with the housing. An engaging section of the inner member is received in the housing. A seal divides the engaging section into a hollow inlet segment and a hollow outlet segment. A plurality of inlet apertures are disposed in the inlet segment and a plurality of outlet apertures are disposed in the outlet segment. The inlet apertures are disposed in a longitudinally and radially spaced-apart pattern that can be a helix. The outlet apertures are disposed in a corresponding pattern. As the inner member is rotated, whenever an inlet aperture overlaps one of the ducts, the corresponding outlet aperture overlaps a different duct, thus forming a fluid pathway.

  1. Rotary multiposition valve

    DOEpatents

    Barclay, J.A.; Dyson, J.E.

    1984-04-06

    The disclosure is directed to a rotary multiposition valve for selectively directing the flow of a fluid through a plurality of paths. The valve comprises an inner member and a hollow housing with a row of ducts on its outer surface. The ducts are in fluid communication with the housing. An engaging section of the inner member is received in the housing. A seal divides the engaging section into a hollow inlet segment and a hollow outlet segment. A plurality of inlet apertures are disposed in the inlet sgegment and a plurality of outlet apertures are disposed in the outlet segment. The inlet apertures are disposed in a longitudinally and radially spaced-apart pattern that can be a helix. The outlet apertures are disposed in a corresponding pattern. As the inner member is rotated, whenever an inlet aperture overlaps one of the ducts, the corresponding outlet aperture overlaps a different duct, thus forming a fluid pathway.

  2. Slow opening valve. [valve design for shuttle portable oxygen system

    NASA Technical Reports Server (NTRS)

    Drapeau, D. F. (Inventor)

    1984-01-01

    A valve control is described having a valve body with an actuator stem and a rotating handle connected to the actuator stem by a differential drive mechanism which, during uniform movement of the handle in one direction, initially opens the valve at a relatively slow rate and, thereafter, complete the valve movement at a substantially faster rate. A series of stop rings are received about the body in frictional abutting relationship and serially rotated by the handle to uniformly resist handle movement independently of the extent of handle movement.

  3. Ball machine usage in tennis: movement initiation and swing timing while returning balls from a ball machine and from a real server.

    PubMed

    Carboch, Jan; Süss, Vladimir; Kocib, Tomas

    2014-05-01

    Practicing with the use of a ball machine could handicap a player compared to playing against an actual opponent. Recent studies have shown some differences in swing timing and movement coordination, when a player faces a ball projection machine as opposed to a human opponent. We focused on the time of movement initiation and on stroke timing during returning tennis serves (simulated by a ball machine or by a real server). Receivers' movements were measured on a tennis court. In spite of using a serving ball speed from 90 kph to 135 kph, results showed significant differences in movement initiation and backswing duration between serves received from a ball machine and serves received from a real server. Players had shorter movement initiation when they faced a ball machine. Backswing duration was longer for the group using a ball machine. That demonstrates different movement timing of tennis returns when players face a ball machine. Use of ball machines in tennis practice should be limited as it may disrupt stroke timing. Key pointsPlayers have shorter initial move time when they are facing the ball machine.Using the ball machine results in different swing timing and movement coordination.The use of the ball machine should be limited.

  4. Ball Machine Usage in Tennis: Movement Initiation and Swing Timing While Returning Balls from a Ball Machine and from a Real Server

    PubMed Central

    Carboch, Jan; Süss, Vladimir; Kocib, Tomas

    2014-01-01

    Practicing with the use of a ball machine could handicap a player compared to playing against an actual opponent. Recent studies have shown some differences in swing timing and movement coordination, when a player faces a ball projection machine as opposed to a human opponent. We focused on the time of movement initiation and on stroke timing during returning tennis serves (simulated by a ball machine or by a real server). Receivers’ movements were measured on a tennis court. In spite of using a serving ball speed from 90 kph to 135 kph, results showed significant differences in movement initiation and backswing duration between serves received from a ball machine and serves received from a real server. Players had shorter movement initiation when they faced a ball machine. Backswing duration was longer for the group using a ball machine. That demonstrates different movement timing of tennis returns when players face a ball machine. Use of ball machines in tennis practice should be limited as it may disrupt stroke timing. Key points Players have shorter initial move time when they are facing the ball machine. Using the ball machine results in different swing timing and movement coordination. The use of the ball machine should be limited. PMID:24790483

  5. Controlled PCV valve

    SciTech Connect

    Zeigler, T.W. Jr.; Romanczuk, C.S.; Betterton, J.T.; Glover, A.H.

    1987-08-18

    A positive crankcase ventilation control device is described for use with an internal combustion engine and, specifically, for controlling the flow of emission laden vaporous fluids from the crankcase thereof, the control device including selective power means for substantially increasing the flow of emission laden air through the device, comprising: a generally hollow housing with an inlet forming portion adapted to be fluidly connected to the interior spaces of an internal combustion engine to receive emission laden air therefrom; the housing having an outlet forming device adapted to be fluidly connected to the air and fuel inletting portion of the internal combustion engine for disposing of the emission laden air from the engine, the inlet and outlet portions being connected within the interior of the housing by a flow control passage of specific flow area; an elongated valve plug member within the housing and having an end portion with a conically tapered configuration adapted to move progressively into the aforesaid flow control passage thereby decreasing the flow area thereof and, consequently, the total flow through the device; yieldable means urging the elongated valve member toward a position ensuring maximum flow through the flow control passage, but being yieldable to allow the valve member to move so that the conically tapered portion progressively extends further into the flow control passage to thereby decrease the flow area.

  6. Passive bypass valve assembly

    SciTech Connect

    Siedlecki, W.F. Jr.

    1992-05-19

    This patent describes a bypass valve assembly for controlling fluid flow in a gas turbine engine. It comprises an annular frame including an outer casing, an inner casing spaced from the outer casing to define a channel for channeling fluid flow and the outer casing including an annular opening therein; a plurality of circumferentially juxtaposed bypass valve doors disposed in the annular opening, each of the valve doors having an inner surface for facing the fluid flowable in the channel, an outer surface, a first end pivotally connected to the frame, and a second end, the doors being positionable in a first position generally parallel to the outer casing, and in a second position inclined relative to the outer casing, the fluid flow flowable against the door inner surface being effective for generating a fluid force on the door; and means for automatically positioning the doors in first and second positions in response to differential pressure across the door, the positioning means providing a torque on the doors for moving the door from the first to the second positions and including torque adjustment means for reducing the torque for at least a portion of travel of the doors from the second to the first positions.

  7. Effect of a ball skill intervention on children's ball skills and cognitive functions.

    PubMed

    Westendorp, Marieke; Houwen, Suzanne; Hartman, Esther; Mombarg, Remo; Smith, Joanne; Visscher, Chris

    2014-02-01

    This study examined the effect of a 16-wk ball skill intervention on the ball skills, executive functioning (in terms of problem solving and cognitive flexibility), and in how far improved executive functioning leads to improved reading and mathematics performance of children with learning disorders. Ninety-one children with learning disorders (age 7-11 yr old) were recruited from six classes in a Dutch special-needs primary school. The six classes were assigned randomly either to the intervention or to the control group. The control group received the school's regular physical education lessons. In the intervention group, ball skills were practiced in relative static, simple settings as well as in more dynamic and cognitive demanding settings. Both groups received two 40-min lessons per week. Children's scores on the Test of Gross Motor Development-2 (ball skills), Tower of London (problem solving), Trail Making Test (cognitive flexibility), Dutch Analysis of Individual Word Forms (reading), and the Dutch World in Numbers test (mathematics) at pretest, posttest, and retention test were used to examine intervention effects. The results showed that the intervention group significantly improved their ball skills, whereas the control group did not. No intervention effects were found on the cognitive parameters. However, within the intervention group, a positive relationship (r = 0.41, P = 0.007) was found between the change in ball skill performance and the change in problem solving: the larger children's improvement in ball skills, the larger their improvement in problem solving. The present ball skill intervention is an effective instrument to improve the ball skills of children with learning disorders. Further research is needed to examine the effect of the ball skill intervention on the cognitive parameters in this population.

  8. Flight trajectory of a rotating golf ball with grooves

    NASA Astrophysics Data System (ADS)

    Baek, Moonheum; Kim, Jooha; Choi, Haecheon

    2014-11-01

    Dimples are known to reduce drag on a sphere by the amount of 50% as compared to a smooth surface. Despite the advantage of reducing drag, dimples deteriorate the putting accuracy owing to their sharp edges. To minimize this putting error but maintain the same flight distance, we have devised a grooved golf ball (called G ball hereafter) for several years. In this study, we modify the shape and pattern of grooves, and investigate the flow characteristics of the G ball by performing wind-tunnel experiments at the Reynolds numbers of 0 . 5 ×105 - 2 . 5 ×105 and the spin ratios (ratio of surface velocity to the free-stream velocity) of 0 - 0.6 that include the real golf-ball velocity and rotational speed. We measure the drag and lift forces on the rotating G ball and compare them with those of a smooth ball and two well-known dimpled balls. The lift-to-drag ratio of the G ball is much higher than that of a smooth ball and is in between those of the two dimpled balls. The trajectories of flying golf balls are computed. The flight distance of G ball is almost the same as that of one dimpled ball but slightly shorter than that of the other dimpled ball. The fluid-dynamic aspects of these differences will be discussed at the talk. Supported by 2011-0028032, 2014M3C1B1033980.

  9. The dynamic impact characteristics of tennis balls with tennis rackets.

    PubMed

    Haake, S J; Carré, M J; Goodwill, S R

    2003-10-01

    The dynamic properties of six types of tennis balls were measured using a force platform and high-speed digital video images of ball impacts on rigidly clamped tennis rackets. It was found that the coefficient of restitution reduced with velocity for impacts on a rigid surface or with a rigidly clamped tennis racket. Pressurized balls had the highest coefficient of restitution, which decreased by 20% when punctured. Pressureless balls had a coefficient of restitution approaching that of a punctured ball at high speeds. The dynamic stiffness of the ball or the ball-racket system increased with velocity and pressurized balls had the highest stiffness, which decreased by 35% when punctured. The characteristics of pressureless balls were shown to be similar to those of punctured balls at high velocity and it was found that lowering the string tension produced a smaller range of stiffness or coefficient of restitution. It was hypothesized that players might consider high ball stiffness to imply a high coefficient of restitution. Plots of coefficient of restitution versus stiffness confirmed the relationship and it was found that, generally, pressurized balls had a higher coefficient of restitution and stiffness than pressureless balls. The players might perceive these parameters through a combination of sound, vibration and perception of ball speed off the racket.

  10. Self-compensating solenoid valve

    NASA Technical Reports Server (NTRS)

    Woeller, Fritz H. (Inventor); Matsumoto, Yutaka (Inventor)

    1987-01-01

    A solenoid valve is described in which both an inlet and an outlet of the valve are sealed when the valve is closed. This double seal compensates for leakage at either the inlet or the outlet by making the other seal more effective in response to the leakage and allows the reversal of the flow direction by simply switching the inlet and outlet connections. The solenoid valve has a valve chamber within the valve body. Inlet and outlet tubes extend through a plate into the chamber. A movable core in the chamber extends into the solenoid coil. The distal end of the core has a silicone rubber plug. Other than when the solenoid is energized, the compressed spring biases the core downward so that the surface of the plug is in sealing engagement with the ends of the tubes. A leak at either end increases the pressure in the chamber, resulting in increased sealing force of the plug.

  11. Optothermally actuated capillary burst valve

    NASA Astrophysics Data System (ADS)

    Eriksen, Johan; Bilenberg, Brian; Kristensen, Anders; Marie, Rodolphe

    2017-04-01

    We demonstrate the optothermal actuation of individual capillary burst valves in an all-polymer microfluidic device. The capillary burst valves are realised in a planar design by introducing a fluidic constriction in a microfluidic channel of constant depth. We show that a capillary burst valve can be burst by raising the temperature due to the temperature dependence of the fluid surface tension. We address individual valves by using a local heating platform based on a thin film of near infrared absorber dye embedded in the lid used to seal the microfluidic device [L. H. Thamdrup et al., Nano Lett. 10, 826-832 (2010)]. An individual valve is burst by focusing the laser in its vicinity. We demonstrate the capture of single polystyrene 7 μm beads in the constriction triggered by the bursting of the valve.

  12. Dark matter balls help supernovae to explode

    NASA Astrophysics Data System (ADS)

    Froggatt, C. D.; Nielsen, H. B.

    2015-10-01

    As a solution to the well-known problem that the shock wave potentially responsible for the explosion of a supernova actually tends to stall, we propose a new energy source arising from our model for dark matter. Our earlier model proposed that dark matter should consist of cm-large white dwarf-like objects kept together by a skin separating two different sorts of vacua. These dark matter balls or pearls will collect in the middle of any star throughout its lifetime. At some stage during the development of a supernova, the balls will begin to take in neutrons and then other surrounding material. By passing into a ball nucleons fall through a potential of order 10 MeV, causing a severe production of heat — of order 10 foe for a solar mass of material eaten by the balls. The temperature in the iron core will thereby be raised, splitting up the iron into smaller nuclei. This provides a mechanism for reviving the shock wave when it arrives and making the supernova explosion really occur. The onset of the heating due to the dark matter balls would at first stop the collapse of the supernova progenitor. This opens up the possibility of there being two collapses giving two neutrino outbursts, as apparently seen in the supernova SN1987A — one in Mont Blanc and one 4 h 43 min later in both IMB and Kamiokande.

  13. Silicon ball grid array chip carrier

    DOEpatents

    Palmer, David W.; Gassman, Richard A.; Chu, Dahwey

    2000-01-01

    A ball-grid-array integrated circuit (IC) chip carrier formed from a silicon substrate is disclosed. The silicon ball-grid-array chip carrier is of particular use with ICs having peripheral bond pads which can be reconfigured to a ball-grid-array. The use of a semiconductor substrate such as silicon for forming the ball-grid-array chip carrier allows the chip carrier to be fabricated on an IC process line with, at least in part, standard IC processes. Additionally, the silicon chip carrier can include components such as transistors, resistors, capacitors, inductors and sensors to form a "smart" chip carrier which can provide added functionality and testability to one or more ICs mounted on the chip carrier. Types of functionality that can be provided on the "smart" chip carrier include boundary-scan cells, built-in test structures, signal conditioning circuitry, power conditioning circuitry, and a reconfiguration capability. The "smart" chip carrier can also be used to form specialized or application-specific ICs (ASICs) from conventional ICs. Types of sensors that can be included on the silicon ball-grid-array chip carrier include temperature sensors, pressure sensors, stress sensors, inertia or acceleration sensors, and/or chemical sensors. These sensors can be fabricated by IC processes and can include microelectromechanical (MEM) devices.

  14. Sequenced drive for rotary valves

    DOEpatents

    Mittell, Larry C.

    1981-01-01

    A sequenced drive for rotary valves which provides the benefits of applying rotary and linear motions to the movable sealing element of the valve. The sequenced drive provides a close approximation of linear motion while engaging or disengaging the movable element with the seat minimizing wear and damage due to scrubbing action. The rotary motion of the drive swings the movable element out of the flowpath thus eliminating obstruction to flow through the valve.

  15. Streamline coal slurry letdown valve

    DOEpatents

    Platt, R.J.; Shadbolt, E.A.

    1983-11-08

    A streamlined coal slurry letdown valve is featured which has a two-piece throat comprised of a seat and seat retainer. The two-piece design allows for easy assembly and disassembly of the valve. A novel cage holds the two-piece throat together during the high pressure letdown. The coal slurry letdown valve has long operating life as a result of its streamlined and erosion-resistance surfaces. 5 figs.

  16. Streamline coal slurry letdown valve

    DOEpatents

    Platt, Robert J.; Shadbolt, Edward A.

    1983-01-01

    A streamlined coal slurry letdown valve is featured which has a two-piece throat comprised of a seat and seat retainer. The two-piece design allows for easy assembly and disassembly of the valve. A novel cage holds the two-piece throat together during the high pressure letdown. The coal slurry letdown valve has long operating life as a result of its streamlined and erosion-resistance surfaces.

  17. Semi-active compressor valve

    DOEpatents

    Brun, Klaus; Gernentz, Ryan S.

    2010-07-27

    A method and system for fine-tuning the motion of suction or discharge valves associated with cylinders of a reciprocating gas compressor, such as the large compressors used for natural gas transmission. The valve's primary driving force is conventional, but the valve also uses an electromagnetic coil to sense position of the plate (or other plugging element) and to provide an opposing force prior to impact.

  18. The performance of the Braunwald-Cutter aortic prosthetic valve.

    PubMed

    Blackstone, E H; Kirklin, J W; Pluth, J R; Turner, M E; Parr, G V

    1977-04-01

    Four hundred seventy-five patients underwent aortic valve replacement with the Braunwald-Cutter ball-valve prosthesis at two institutions. The early (30-day) hospital mortality was 4.7% for those with isolated aortic valve replacement and 6.9% for the entire group. For the former, 5-year actuarial survival of the hospital survivors was 72 +/- 5.7%; for the latter group it was 71 +/- 4.4%. Eleven patients (5 since the date of follow-up inquiry) have suffered poppet escape, 9 of whom died. The actuarial incidence of known poppet escape is 4 +/- 2.6% at 47 months; when the 5 patients suffering poppet escape since the date of follow-up inquiry are included, with certain assumptions, the incidence is 3.7 +/- 1.14%. The projected probability of poppet escape using all 11 patients is 12.2% at 5 years; the 70% confidence bands of projected probability of poppet escape separate from those of the risk of re-replacement at 61 months. This and other analyses indicate that in general, patients with the Braunwald-Cutter aortic prosthesis should have it replaced 4 1/2 to 5 years after its insertion.

  19. Prosthetic aortic valves. Indications for and results of reoperation.

    PubMed

    Shemin, R J; Guadiani, V A; Conkle, D M; Morrow, A G

    1979-01-01

    During a 15-year period from January 1962 through December 1976, 42 patients who had undergone a previous aortic valve replacement underwent reoperation. The mean interval between operations was 4.4 years. The indications for reoperation were aortic regurgitation resulting from mechanical malfunction (12 patients), ball variance (15 patients), perivalvular leaks (five patients), prosthetic stenosis (eight patients), anemia (one patient), and recurrent emboli (one patient). The indications were characteristic of a specific valve series. The most common reoperation was aortic valve replacement (29/42), which had a 10.3% operative mortality. Poppet change (10/42) carried a 10% operative mortality and no operative deaths followed suture closure of perivalvular leaks. Eighty-eight percent of patients alive six months after reoperation were New York Heart Association functional class 1 or 2. At last follow-up, 95% of surviving patients were still functional class 1 or 2, with a mean cumulative survival of 4.7 years after reoperation. This experience demonstrates that those patients surviving long enough to undergo reoperation can expect a reasonable operative risk, long-term survival, and excellent clinical improvement.

  20. Innovative Stemless Valve Eliminates Emissions

    NASA Technical Reports Server (NTRS)

    2008-01-01

    Big Horn Valve Inc. (BHVI), of Sheridan, Wyoming, won a series of SBIR and Small Business Technology Transfer (STTR) contracts with Kennedy Space Center and Marshall Space Flight Center to explore and develop a revolutionary valve technology. BHVI developed a low-mass, high-efficiency, leak-proof cryogenic valve using composites and exotic metals, and had no stem-actuator, few moving parts, with an overall cylindrical shape. The valve has been installed at a methane coal gas field, and future applications are expected to include in-flight refueling of military aircraft, high-volume gas delivery systems, petroleum refining, and in the nuclear industry.