Science.gov

Sample records for starr-edwards ball valve

  1. Reoperation on a Starr-Edwards ball valve without structural deterioration.

    PubMed

    Hayatsu, Yukihiro; Saito, Takeshi; Adachi, Osamu; Kumagai, Kiichiro; Akiyama, Masatoshi; Motoyoshi, Naotaka; Kawamoto, Shunsuke; Saiki, Yoshikatsu

    2012-12-01

    Accurate measurement of pressure gradients on echocardiography across a Starr-Edwards (SE) ball valve is difficult due to its unique flow pattern. The decision of indication for reoperation on the valve requires multifactorical evaluation. We report a surgical case with an aortic SE ball valve 43 years after implantation. There was no apparent structural deterioration on the ball per se, yet, remarkable pannus formation was noted beneath the sewing cuff in the left ventricular outflow tract.

  2. Replacement of the Aortic and Mitral Valves Using the Starr-Edwards Ball-Valve Prosthesis

    PubMed Central

    Callaghan, John C.

    1964-01-01

    The aortic and mitral valves were replaced in 50 patients at the University of Alberta Hospital using the Starr-Edwards ball-valve prosthesis. The basis of the selection of 20 patients for isolated aortic valve replacement and 27 for mitral valve replacement using this type of prosthesis is presented, and the techniques of insertion of the aortic and mitral valve are described in detail. Of the 27 patients in whom the mitral valve was replaced by the Starr-Edwards prosthesis six died within 30 days of surgery and two after discharge from hospital at two and a half and four months, respectively. Left atrial thrombosis was the cause of death in four of these patients. In 20 patients in whom the aortic valve was replaced, four died in hospital and two died more than 30 days after returning home. Three of these six patients died from bleeding—the result of the use of anticoagulants. The difficulty in assessing whether or not anticoagulants are needed following replacement by a Starr-Edwards prosthesis is considered. It is felt, in our present state of knowledge, that anticoagulants should be used following mitral valve replacement but are probably not essential following replacement of the aortic valve. Two patients survived replacement of both aortic and mitral valves and have been followed up 18 months and seven months, respectively. ImagesFig. 1Fig. 2Fig. 4Fig. 5Fig. 7Fig. 9Fig. 10Fig. 11Fig. 12Fig. 13 PMID:14179062

  3. Intermediate Term Evaluation of Starr-Edwards Ball Valves in the Mitral Position

    PubMed Central

    Cotrufo, Maurizio; Renzulli, Attilio; Esposito, Vincenzo; Vosa, Carlo; Nappi, Giannantonio; Deluca, Luigi; Casale, Domenico; Bellitti, Renato; Festa, Michele

    1985-01-01

    The Model 6120 ball valve prosthesis introduced in 1965 is still strongly supported as a mitral valve substitute in many centers around the world. A current reassessment of the performance of this prosthesis is therefore pertinent to current medical practice. In this institution since 1974, 227 Starr-Edwards caged ball valves have been implanted in the mitral position during isolated valve replacement. Two models of caged ball valves were used concurrently: the silastic ball valve in 108 patients (48%) and the composite strut “tract” valve in 119 (52%). Hospital mortality was 7%, and 8-year survival (standard error) was 74 (6%), with 100% follow-up, documenting 752 total patient-years. No late deaths were known to be valve related, and there were no cases of prosthetic thrombosis. The actuarial estimate of patients free from thromboembolism at 8 years was 89 (4%) with a linearized rate of 1.3% per year. At the most recent follow-up, 95% of the patients were in the New York Heart Association (NYHA) Classes I or II. These good results were partly due to an awareness at operation of ventricular outflow tract size requirements and to strict control of postoperative anticoagulation. We conclude that the Starr-Edwards ball valve is the mitral valve of choice in the young patient who is able to take anticoagulation drugs and has a left ventricular outflow tract of satisfactory size. PMID:15227040

  4. Bentall procedure 39 years after implantation of a Starr-Edwards Aortic Caged- Ball-Valve Prosthesis

    PubMed Central

    2010-01-01

    We report a case of a male patient who received an implantation of a Starr-Edwards-caged-ball-valve-prosthesis in 1967. The surgery and postoperative course were without complications and the patient recovered well after the operation. For the next four decades, the patient remained asymptomatic - no restrictions on his lifestyle and without any complications. In 2006, 39 years after the initial operation, we performed a Bentall-Procedure to treat an aortic ascendens aneurysm with diameters of 6.0 × 6.5 cm: we explanted the old Starr-Edwards-aortic-caged-ball-valve-prosthesis and replaced the ascending aorta with a 29 mm St.Jude Medical aortic-valve-composite-graft and re-implanted the coronary arteries. This case represents the longest time period between Starr-Edwards-caged-ball-valve-prothesis-implantation and Bentall-reoperation, thereby confirming the excellent durability of this valve. PMID:20298579

  5. Bentall procedure 39 years after implantation of a Starr-Edwards aortic caged-ball-valve prosthesis.

    PubMed

    Schmitto, Jan D; Ortmann, Philipp; Popov, Aron F; Coskun, Kasim O; Schotola, Hanna; Friedrich, Martin; Wiese, Christoph H; Sohns, Christian; Mokashi, Suyog A; Didilis, Vassilios N; Schoendube, Friedrich A

    2010-03-18

    We report a case of a male patient who received an implantation of a Starr-Edwards-caged-ball-valve-prosthesis in 1967. The surgery and postoperative course were without complications and the patient recovered well after the operation. For the next four decades, the patient remained asymptomatic--no restrictions on his lifestyle and without any complications. In 2006, 39 years after the initial operation, we performed a Bentall-Procedure to treat an aortic ascendens aneurysm with diameters of 6.0 x 6.5 cm: we explanted the old Starr-Edwards-aortic-caged-ball-valve-prosthesis and replaced the ascending aorta with a 29 mm St.Jude Medical aortic-valve-composite-graft and re-implanted the coronary arteries.This case represents the longest time period between Starr-Edwards-caged-ball-valve-prosthesis-implantation and Bentall-reoperation, thereby confirming the excellent durability of this valve.

  6. A case of the Starr-Edwards ball valve (Model 6120) in the mitral position for 45 years.

    PubMed

    Azuma, Shuhei; Morita, Masafumi; Yoshii, Yasuhiro; Mieno, Shigetoshi

    2015-02-01

    A 59-year-old male who had undergone mitral valve replacement with the Starr-Edwards ball valve Model 6120 (S-E ball valve) 45 years ago was admitted to our hospital for hemolytic anemia and heart failure. Echocardiography revealed that there was no valve dysfunction but paravalvular leakage between the annulus of P2 and the sewing ring of the Starr-Edwards ball valve. He underwent mitral valve replacement. The S-E ball valve was successfully replaced with bileaflet mechanical valve. The explanted S-E ball valve was free from signs of structural valve degeneration. This case shows one of the longest durability of the S-E ball valve in mitral position in the world.

  7. Excellent durability of Starr-Edwards ball valves implanted in the aortic and mitral positions for 27 years: report of a rare surgical case.

    PubMed

    Tochii, Masato; Takagi, Yasushi; Kaneko, Kan; Ishida, Michiko; Akita, Kiyotoshi; Higuchi, Yoshiro; Ando, Motomi

    2013-01-01

    A 59-year-old male who had undergone aortic and mitral valve replacement with Starr-Edwards ball valves 27 years ago was admitted to our hospital for hemolytic anemia and heart failure. Echocardiography revealed prosthetic valve failure with a high-pressure gradient and small effective orifice area. The Starr-Edwards ball valves were successfully replaced with bileaflet mechanical valves. The explanted valves revealed no structural abnormalities.

  8. Ascending aortic aneurysm in a patient with an aortic Starr-Edwards ball valve prosthesis implanted 39 years previously.

    PubMed

    Nishigawa, Kosaku; Totsugawa, Toshinori; Yoshitaka, Hidenori; Tsushima, Yoshimasa; Kuinose, Masahiko; Chikazawa, Genta

    2010-03-01

    A 53-year-old man who had undergone aortic valve replacement with a Starr-Edwards ball valve prosthesis 39 years previously was admitted to our hospital under the diagnosis of ascending aortic aneurysm. Operative findings revealed that the ball valve was functioning normally. The markedly dilated ascending aorta was replaced with a 30-mm prosthetic vascular graft, and the ball valve was replaced with a19-mm bileaflet valve prosthesis. The patient's postoperative course was uneventful, and he was discharged from our hospital 19 days after surgery. Dilatation of the ascending aorta in this case might have been caused by the poststenotic dilatation mechanism, which seems to be one of the long-term complications of Starr-Edwards ball valve implantation.

  9. Starr-Edwards valves at the aortic and mitral positions implanted for 39 years.

    PubMed

    Misawa, Shun-ichi; Aizawa, Kei; Kaminishi, Yuichiro; Muraoka, Arata; Misawa, Yoshio

    2011-06-01

    Cloth-covered Starr-Edwards caged ball valves implanted in the aortic and mitral valve positions for 39 years were extracted. Both showed valve dysfunction resulting from pannus overgrowth. The metal cages of the Starr-Edwards valves were covered with worn cloth. This case indicates the extended durability of Starr-Edwards valves and the importance of the design and materials of prosthetic heart valves to avoid pannus overgrowth and prosthetic valve abrasion.

  10. Intravascular haemolysis after valve replacement: comparative study between Starr-Edwards (ball valve) and Björk-Shiley (disc valve) prosthesis.

    PubMed Central

    Falk, R H; Mackinnon, J; Wainscoat, J; Melikian, V; Bignell, A H

    1979-01-01

    Seventy-four patients with single prosthetic valves (Björk-Shiley or Starr-Edwards) in the mitral or aortic position and 18 controls with rheumatic valvar heart disease were investigated for evidence of intravascular haemolysis. Serum lactate dehydrogenase (LDH) was used as the most sensitive indicator of haemolysis. Raised concentrations were found in a third of 39 patients with Björk-Shiley prostheses (mean 281 IU/l) and in all 35 patients with Starr-Edwards prostheses (mean 859 IU/l. Values were considerably higher in patients with Starr-Edwards prostheses and particularly in those with aortic prostheses (mean 927 IU/l). Eight out of 12 patients with haemosiderinuria had Starr-Edwards valves. Intravascular haemolysis was of little clinical significance in patients with Björk-Shiley prostheses, but some patients with Starr-Edwards prostheses became iron deficient as a result. PMID:542913

  11. The development of the Starr-Edwards heart valve.

    PubMed Central

    Matthews, A M

    1998-01-01

    Development of the Starr-Edwards heart valve marked a new era in the treatment of valvular heart disease. Until the development of the Starr-Edwards valve, there were no published reports of patients who had lived longer than 3 months with a prosthetic valve in the mitral position. This valve was the result of a unique partnership between a young surgeon, Dr. Albert Starr, and an experienced engineer, Mr. Lowell Edwards. Working as a team, these 2 men developed and successfully implanted the 1st Starr-Edwards valve within less than 2 years of their 1st meeting. Their key to success was their willingness and ability to make repeated modifications to their design to solve each clinical problem as it arose. Their constant focus on the clinical goal aided the rapid transformation of their design from a leaflet valve to a shielded ball valve, and finally to an unshielded ball valve suitable for implantation in a human being. Along the way, they abandoned the idea of imitating the appearance of native valves, in favor of developing valves that would be clinically successful. Their work has provided help and hope for patients who otherwise would have died from the complications of rheumatic heart disease and other valvular disorders for which valve replacement is the only treatment. Images PMID:9885105

  12. Salutary swan song for the Starr Edwards valve.

    PubMed

    Masilonyane-Jones, Taolo Vijay; Blackham, Ruth; Alvarez, John

    2010-07-01

    The Starr-Edwards valve was the first manufactured valve to be used successfully as a cardiac valve replacement in 1960. Although superseded by newer valves over the decades it has achieved an excellent track record. It has unique features, namely a protective metal casing around the ball poppet and a large and thick sewing ring. We describe the last implant of this valve in Australia; it has now been withdrawn by the manufacturer. In this particular case, the unique features of this valve made the required surgery quite simple and avoided the need for complex mitral valve surgery in a very high-risk patient.

  13. A case of Starr-Edwards valve thrombosis in pregnancy.

    PubMed

    Davis, Margot; Kiess, Marla; Rychel, Valerie; Fofonoff, Doreen; Grewal, Jasmine

    2012-11-01

    Starr-Edwards ball-in-cage prosthetic heart valves, although durable, are associated with a particularly high rate of thromboembolic complications. This valve is seldom used in North America, and is certainly not the valve of choice in a woman of childbearing age. Few reports exist from the 1970s of thrombotic complications in pregnant women with Starr-Edwards prostheses, and the optimal management strategy for such valves is unclear. Here, the case is reported of a 31-year-old woman with a Starr-Edwards prosthesis in the mitral position who was transferred to the authors' center at six weeks' gestation with pulmonary edema. Transthoracic echocardiography demonstrated thrombosis of the prosthetic valve, with a mean gradient of 23 mmHg. When treated initially with intravenous heparin and furosemide the patient improved significantly; however, the optimal management going forward was unclear. Here, the options for anticoagulation during pregnancy and for management in the event of valve thrombosis are reviewed. In the absence of any clear guidelines, a thorough discussion of the various risks and benefits with the patient is necessary, but ultimately any consideration of the risk to the mother is paramount.

  14. Long-term Results in 1375 Patients Undergoing Valve Replacement with the Starr-Edwards Cloth-covered Steel Ball Prosthesis

    PubMed Central

    Isom, O. Wayne; Spencer, Frank C.; Glassman, Ephraim; Teiko, Phyllis; Boyd, Arthur D.; Cunningham, Joseph N.; Reed, George E.

    1977-01-01

    The two principal considerations with prosthetic valves are durability and thromboembolism. With the widespread interest in recently developed prosthetic valves (porcine, tilting disc, Cooley), the long-term results at one institution with a single prosthesis were considered of particular importance. Accordingly, a 97% follow-up has been completed on 1375 patients (pts) undergoing prosthetic valve replacement with the Starr-Edwards cloth-covered steel ball prosthesis at New York University between October 1967 and December 1975. Operative procedures were as follows: aortic valve replacement (AVR): 470 pts; mitral valve replacement (MVR): 362 pts; combined AVR and MVR: 129 pts; other combined procedures: 414 pts. Overall operative deaths were 13.7%, 9% for AVR, 10.8% for MVR, and 18.6% for combined AVR and MVR. At seven years, AVR survival was 64%, and MVR survival 64.5%. There has been widespread pessimism, usually without significant data, about the cloth-covered prosthesis, because of concern of cloth wear, hemolysis and other complications. Therefore, a particularly significant finding by actuarial analysis was that 85% of surviving patients with isolated AVR remained free of emboli for five years. In pts surviving isolated MVR, 80% remained free of emboli for five years. Of those having embolic episodes, 33% were not on anticoagulants. Fatal hemorrhage from anticoagulants occurred in 0.8% of pts. Endocarditis occurred in 5.7% of the entire group, with 1.3% requiring reoperation. Clinically significant hemolysis occurred in 5.1% of the group, with only 0.2% requiring reoperation. Hence, the total frequency of clinically significant cloth-wear was less than 0.5%. These data indicate both the reliability and the limitations of the Starr-Edwards cloth-covered steel ball valve and can be used in comparing experiences with the more recently developed prostheses. PMID:889374

  15. Premature valve closure in patients with a mitral Starr-Edwards prosthesis and aortic incompetence

    PubMed Central

    Agnew, T. M.; Carlisle, R.

    1970-01-01

    A mitral Starr-Edwards ball valve has, in three patients with concomitant aortic incompetence, permitted recognition of intermittent premature valve closure by auscultation and this has been documented by phonocardiograms. In two instances the observations were confirmed during cardiac catheterization. The features of premature Starr valve closure are described and the mechanism is discussed. Images PMID:5433303

  16. Structural Failure of a Starr-Edwards Aortic Track Valve

    PubMed Central

    Ringel, Richard E.; Moulton, Anthony L.; Burns, Janet E.; Brenner, Joel I.; Berman, Michael A.

    1983-01-01

    Structural failure of a Model 2400 Starr-Edwards aortic track valve occurred suddenly, 4 years after implantation. At operation, the valve cage was removed from the descending aorta. Examination of the excised prosthesis disclosed minimal cloth wear and no evidence of infective growth; however, three struts were fractured above their insertion into the valve ring. To our knowledge, this type of valve malfunction has not been previously noted. Images PMID:15227160

  17. Haemolysis with Björk-Shiley and Starr-Edwards prosthetic heart valves: a comparative study

    PubMed Central

    Slater, S. D.; Sallam, I. A.; Bain, W. H.; Turner, M. A.; Lawrie, T. D. V.

    1974-01-01

    Slater, S. D., Sallam, I. A., Bain, W. H., Turner, M. A., and Lawrie, T. D. V. (1974).Thorax, 29, 624-632. Haemolysis with Björk-Shiley and Starr-Edwards prosthetic heart valves: a comparative study. A comparison was made of the haemolytic complications in 85 patients with two different types of Starr-Edwards cloth-covered ball and cage prosthesis with those in 44 patients with the Björk-Shiley tilting disc valve. Intravascular haemolysis, as detected by the presence of haemosiderinuria, occurred significantly less often with the Björk-Shiley than with the Starr-Edwards valve, the overall incidence with aortic, mitral or multiple replacements being 31%, 15%, and 20% for Björk-Shiley and 94%, 92%, and 88% for Starr-Edwards valves respectively. There was no significant difference in the frequency of haemolysis between each of the two types of Starr-Edwards prosthesis studied at either the aortic (2300 versus 2310 model) or mitral (6300 versus 6310) site. Haemolytic anaemia developed in only one patient with a Björk-Shiley valve but was common though usually mild with Starr-Edwards prostheses, particularly aortic valve replacements with the 2300 model and in aortic plus mitral (± tricuspid) replacements. The greater severity of haemolysis produced by Starr-Edwards valves, again especially of the latter types, was further demonstrated by higher serum lactate dehydrogenase and 24-hour urinary iron levels. It is concluded that the Björk-Shiley tilting disc valve represents a significant advance in the amelioration of the haemolytic complications of prosthetic valves. PMID:4450173

  18. Paraprosthetic leak closure 28 years after mitral caged-ball Starr-Edwards implantation.

    PubMed

    Antończyk, Karolina; Paluszkiewicz, Lech; Koertke, Heinrich; Gummert, Jan

    2013-08-01

    In this case report, we present a patient 28 years after mitral valve replacement with the Starr-Edwards prosthesis complicated by periprosthetic leak with severe aortic stenosis and moderate tricuspid regurgitation. We successfully repaired the periprosthetic regurgitation in a patient with extensive mitral annular calcification, without replacement of the valve. No apparent structural deterioration on the caged-ball valve was found. Moreover, aortic valve replacement and tricuspid annuloplasty were performed. One month after reoperation, the patient remained stable with improved clinical status and without any evidence for further paravalvular leak.

  19. Paraprosthetic leak closure 28 years after mitral caged-ball Starr-Edwards implantation

    PubMed Central

    Antończyk, Karolina; Paluszkiewicz, Lech; Koertke, Heinrich; Gummert, Jan

    2013-01-01

    In this case report, we present a patient 28 years after mitral valve replacement with the Starr-Edwards prosthesis complicated by periprosthetic leak with severe aortic stenosis and moderate tricuspid regurgitation. We successfully repaired the periprosthetic regurgitation in a patient with extensive mitral annular calcification, without replacement of the valve. No apparent structural deterioration on the caged-ball valve was found. Moreover, aortic valve replacement and tricuspid annuloplasty were performed. One month after reoperation, the patient remained stable with improved clinical status and without any evidence for further paravalvular leak. PMID:23599186

  20. [The Starr-Edwards heart valve: one of the oldest mechanical heart valves still functioning today].

    PubMed

    Schoenaker, Michiel H; van Wetten, Herbert B; Morshuis, Wim J

    2015-01-01

    In the 1960s, the Starr-Edwards valve was the first artificial heart valve to be successfully implanted in humans. This valve has now been in use for decades with outstanding results: patients whose life expectancy had previously been short acquired a good prognosis with this development. Nowadays the Starr-Edwards valve is not used anymore, but patients are being described today in whom these valves are still functioning well after more than 40 years.

  1. Valve Replacement with the Starr-Edwards and Hancock Prostheses: Comparative Analysis of Late Morbidity and Mortality

    PubMed Central

    Oyer, Philip E.; Stinson, Edward B.; Griepp, Randall B.; Shumway, Norman E.

    1977-01-01

    Although the Starr-Edwards caged-ball valve remains a standard of comparison for more recently introduced prostheses, a substantial incidence of thromboembolic and hemorrhagic complications prompted our evaluation of the Hancock glutaraldehyde-fixed porcine xenograft. We have compared the results of 435 aortic valve replacements using the Starr- Edwards valve (SE-AVR), 515 mitral valve replacements (SE-MVR), and 121 double-valve replacements (SE-AVRMVR) with 251 aortic valve replacements using the xenograft aortic valve (X-AVR), 338 mitral valve replacements (X-MVR), and 88 double-valve replacements (X-AVR-MVR). The Starr- Edwards valves were used during the period 1963 through 1973 and the xenograft valves between 1971 and 1976. No significant differences in patient age, sex, or preoperative hemodynamic data were noted between comparable groups. All patients with Starr-Edwards valves received long-term anticoagulation while anticoagulants were used only for specific indications in patients with xenograft valves. Total follow up was 3944 patient years for the Starr-Edwards patients and 947 patient years for the xenograft patients. Hospital mortality was not significantly different for comparable groups: SE-AVR 6.9% vs. X-AVR 6.4%, SE-MVR 9.7% vs X-MVR 8.6%, and SE-AVR-MVR 7.5% vs. X-AVR-MVR 10.2%. Linearized mortality and morbidity data expressed as percent per patient- year are tabulated below. Pairs which differ significantly (p < .05) are italicized. PMID:560824

  2. Ten year clinical evaluation of Starr-Edwards 2400 and 1260 aortic valve prostheses.

    PubMed Central

    Hackett, D; Fessatidis, I; Sapsford, R; Oakley, C

    1987-01-01

    The long term performance characteristics of the 2400 and 1260 series of Starr-Edwards aortic prostheses were investigated by a follow up study of clinical outcome of 327 patients discharged from hospital with isolated aortic valve replacement. Follow up lasted for up to 10 years and was based on 1616 patient-years. The 2400 series cloth covered tracked valve was implanted in 182 patients from 1974 to 1980 and the 1260 series bare strut silastic ball valve was inserted in 145 patients from 1979 to 1983. Total 10 year mortality and valve related morbidity were low and no cases of mechanical valve failure were recorded. There were no significant actuarial differences in mortality or valve related morbidity between the 2400 and 1260 valves. Starr-Edwards models 2400 and 1260 aortic valve prostheses showed excellent durability without any mechanical failures over a 10 year period. The long term outcome of isolated aortic valve replacement with these models is associated with a low frequency of valve related complications. PMID:3580223

  3. Durability, reliability, viability: 48 year-survival of a Starr-Edwards mitral valve.

    PubMed

    Ayub, Bilal; Guthier, Justin; Wu, James K; Martinez, Matthew W

    2014-01-01

    We report a case of 67 year-old female with a 48-year survival of a Starr-Edwards valve at mitral position. The patient underwent Starr-Edwards mitral valve replacement at age of 19 years for mitral stenosis secondary to severe rheumatic valve disease. The patient had experienced a progressive decline in her functional status with increasing dyspnoea on exertion over a two-week period to eventual development of severe shortness of breath at rest prior to hospitalisation. Transoesophageal echocardiogram revealed severe para-prosthetic and intravalvular mitral valve regurgitation. The patient underwent explantation of Starr-Edwards valve and replacement with a mechanical prosthesis. Our case details the longest reported survival of a Starr-Edwards prosthetic valve at mitral area.

  4. Favorable evolution of a 43-year-old Starr-Edwards valve in the tricuspid position.

    PubMed

    Aludaat, Chadi; Gay, Arnaud; Guetlin, Amina; Nafeh-Bizet, Catherine; Bessou, Jean-Paul; Doguet, Fabien

    2012-09-01

    The durability of a Starr-Edwards valve implanted in the tricuspid position in 1967 to treat Ebstein's disease with tricuspid valve regurgitation. At surgery, cardiac permanent pacing for postoperative complete atrioventricular block was achieved using a nuclear-powered pacemaker (NP). Although the 43rd year of cardiologic follow up was free from complications, the patient--a 74-year-old woman--suffered symptomatic mitral regurgitation and underwent a redo mitral valve replacement, during which the Starr-Edwards valve and NP were left in place.

  5. Disc wear and entrapment in a Starr-Edwards mitral caged-disc valve.

    PubMed

    Aoyagi, Shigeaki; Fukunaga, Shuji; Arinaga, Koichi

    2011-07-01

    A case of wear and entrapment of a polyethylene disc observed in a Starr-Edwards (SE) mitral caged-disc valve at 37 years after implantation is reported. A 66-year-old woman who had undergone mitral valve replacement with a SE disc valve 37 years previously was admitted to the authors' hospital. Cinefluoroscopy showed the polyethylene disc of the SE valve to have impinged against a calcified mass on the left ventricular posterior wall, causing a tipping motion of the disc during opening. The valve was successfully replaced at surgery. A macroscopic examination of the excised valve revealed wear of the polyethylene disc at sites where the disc abutted the cage struts, and where it impinged on the calcified mass. The long-term durability of the SE caged-disc valves has been favorable; however, when implanted for over 20 years, they should be carefully followed up.

  6. Late results of aortic valve replacement with the Starr-Edwards prosthesis.

    PubMed Central

    Morgans, C M; Barritt, D W; Belsey, R H; Keen, G; Wensley, R

    1970-01-01

    Details are presented concerning 59 patients who left hospital between January 1964 and January 1969 after aortic valve replacement with the Starr-Edwards prosthesis. Of the 14 late deaths, 7 are known to have been due to causes related to the prosthesis and 4 to other causes. The 45 surviving patients have nearly all shown clinical improvement and only 3 are unable to work as a result of some complication of the operation. Aortic regurgitation and its consequences appear to be the most significant factor leading to symptoms. In 11 of 16 patients with anaemia there was evidence of intravascular haemolysis. The long-term consequence of this complication is not known. Images PMID:5212355

  7. A Starr-Edwards mitral prosthesis after 44 years of good performance.

    PubMed

    De Santo, Luca Salvatore; De Feo, Marisa; Della Corte, Alessandro; Cerasuolo, Flavio; Santé, Pasquale; Torella, Michele; Nappi, Gianantonio

    2010-06-01

    The Starr-Edwards caged-ball prosthesis has been widely used to replace cardiac valves. The Model 6120 mitral prosthesis was introduced on the market in 1965 to reduce the high incidence of ball variance and thromboembolism of the previous model. We report the case of a Starr-Edwards Model 6120 which had been in place for 44 years and was still well functioning with no apparent structural damage.

  8. Prosthetic Valve Dysfunction 35 Years after Mitral Valve Replacement with a Starr-Edwards Caged-disc Valve.

    PubMed

    Yokokawa, Tetsuro; Ohara, Takahiro; Takashio, Seiji; Sakamoto, Mari; Wada, Yuko; Nakamura, Kenji; Takahama, Hiroyuki; Amaki, Makoto; Hasegawa, Takuya; Sugano, Yasuo; Kanzaki, Hideaki; Yasuda, Satoshi; Ogawa, Hisao; Fujita, Tomoyuki; Kobayashi, Junjiro; Okamoto, Yoko; Matsuyama, Taka-Aki; Ishibashi-Ueda, Hatsue; Anzai, Toshihisa

    2016-01-01

    A 49-year-old man was admitted to our hospital with a chief complaint of dyspnea. He had a history of mitral valve replacement (MVR) with a Starr-Edwards (SE) caged-disc valve at the age of 14. Echocardiography revealed elevated trans-valvular pressure gradient of the mitral prosthetic valve with neither disk motion abnormality nor abnormal structure. Catheterization confirmed an elevation of the mean diastolic gradient of the mitral valve to 12.3 mmHg. Re-MVR was performed, and abnormal tissue attached to the cage of the valve and proliferating beneath the valve was observed. Histologic examination revealed them as fibrinous tissue and mild pannus proliferation, respectively. This rare case report focuses on long-term follow-up and the complication of a SE caged-disc valve. A SE caged-disc valve may become stenotic, only detected with a trans-valvular pressure gradient without any disk motion abnormality or abnormal structure during a prolonged follow-up period.

  9. Phonocardiographic method of assessing changes in left ventricular function after Starr-Edwards replacement of aortic valve

    PubMed Central

    Gibson, D. G.; Broder, G.; Sowton, E.

    1970-01-01

    A phonocardiographic method is described for measuring the time taken by the ball of a Starr-Edwards prosthesis to move to the apex of the cage at the onset of left ventricular ejection, and from this its acceleration can be derived. The acceleration is conspicuously increased in post-ectopic beats and in exercise, but is unaffected by posture and tachycardia induced by atropine or ventricular pacing. It is suggested that the acceleration of the ball is related to the initial acceleration of blood into the ascending aorta. Images PMID:5440511

  10. Total Replacement of the Mitral Valve: Results of Insertion of a Starr-Edwards Valve in Five Patients

    PubMed Central

    Callaghan, John C.

    1963-01-01

    In five patients the mitral valve was resected and total valve replacement undertaken. The Starr-Edwards prosthesis was inserted. The first patient died, two and one-half months after operation, of a wide massive left-atrial clot and peripheral embolization. The second and third patients are well and back at work at eight months after operation, and the fourth patient is well at two and one-half months after operation. The fifth patient died suddenly at three weeks from massive peripheral embolization originating from the left side of the heart. The technical details of the insertion of the valves are described and the importance of careful postoperative anticoagulant management is stressed. ImagesFig. 1Fig. 2Fig. 3Fig. 4Fig. 5Fig. 6 PMID:14017893

  11. Long-term Results of Aortic Valve Replacement with the Starr-Edwards Valve

    PubMed Central

    Fleming, James; Hamer, John; Hayward, Graham; Tubbs, O. S.; Hill, Ian

    1969-01-01

    Review of the 74 patients undergoing aortic valve replacement with a Starr–Edwards ball-valve prosthesis between October 1963 and December 1967 showed that 16 died during surgery or within the first month after operation, usually owing to myocardial failure; and there were nine late deaths. The remaining patients developed few major complications, and the long-term results of operation are considered satisfactory, no patient being grossly incapacitated and most of them are leading active, symptom-free lives. ImagesFig. 1 PMID:5762272

  12. Patient with a Starr-Edwards prosthesis in the aortic position for 40 years.

    PubMed

    Miranda, Matheus; do Nascimento, Luciene; Haddad, Michel Raineri; Haddad, William Teixeira; Haddad, William Teixeira; Buffolo, Enio

    2013-09-01

    Herein is reported the case of a patient who presented initially with aortic insufficiency and a fistula between the sinus of Valsalva and right atrium when aged 31 years. Closure of the fistula and replacement of the aortic valve with a Starr-Edwards A-9 caged-ball prosthesis was performed in 1972, since when the valve has survived for 40 years without dysfunction. This is one of the longest follow ups of the Starr-Edwards prosthesis reported, and highlights the possibility of acceptable valve performance over long periods of time.

  13. Chronic haemolysis after Lillehei-Kaster valve replacement. Comparison with the findings after Björk-shiley and Starr-Edwards mitral valve replacement.

    PubMed Central

    Rao, K M; Learoyd, P A; Rao, R S; Rajah, S M; Watson, D A

    1980-01-01

    Nineteen female and sixteen male patients who have had their heart valves replaced with Lillehei-Kaster valves were investigated for haemolysis four to 18 months after operation. Investigation included serum lactic dehydrogenase, serum haptoglobins, and urine haemosiderin. Red cells survival, using autologous red cells labelled with 51Cr, was measured in 12 patients. No patient showed manifest anaemia. The serum lactic dehydrogenase levels were raised in 66% of the mitral valve patients, 81% of the aortic valve patients, and in all the double valve patients. The serum haptoglobins were decreased in 66% of mitral patients, 68% of aortic valve patients, and in 75% of the double valve patients. All the 12 patients studied had lower than normal red cell survivals. No correlation was found between the incidence of haemolysis and the size of the valve. In isolated mitral valve replacement 66% showed compensated haemolysis compared with 42% in Björk-Shiley valves (p less than 0.05), 85% in Starr-Edwards valves (composite seat) (p less than 0.01), and none in frame-mounted irradiated homografts (previous study) (p less than 0.001). PMID:7434271

  14. Results after mitral valve replacement with cloth-covered Starr-Edwards prostheses (models 6300, 6310/6320, and 6400).

    PubMed Central

    Forman, R; Beck, W; Barnard, C N

    1978-01-01

    The actuarial survival and thromboembolic rates for the three types of cloth-covered Starr-Edwards mitral prostheses, models 6300, 6310/6320, and 6400 followed 6, 5, and 2 years, respectively, were not significantly different throughout the years they were followed. The combined cumulative survival and thromboembolic proportion at 5 years for these prostheses were 71 and 66 per cent, respectively. The thromboembolic rates were not different in the following two groups: (a) 238 patients receiving anticoagulants, and (b) 52 patients who had discontinued or who were not receiving anticoagulants. Four patients thrombosed their mitral prostheses. Another 8 per cent had class 3 symptoms after operation, which were attributed to myopathic or restrictive left ventricular dysfunction or other valvular disease. PMID:656234

  15. Transcatheter treatment of Starr-Edwards paravalvular leaks.

    PubMed

    Santoro, Giuseppe; Scognamiglio, Giancarlo; Gaio, Gianpiero; Iacono, Carola; Giugno, Luca; Russo, Maria G

    2014-06-28

    A 56-year-old patient was referred because of refractory heart failure and mild haemolysis caused by multiple, severe paravalvular leaks of a Starr-Edwards valve implanted in mitral position 23 years before. Owing to perceived high risk of surgical re-valving, percutaneous paravalvular leak occlusion was performed by implantation of multiple, simultaneously deployed Amplatzer Vascular Plugs.

  16. Acute dysfunction of Starr-Edwards mitral prostheses

    PubMed Central

    Gunstensen, John

    1971-01-01

    Four cases of acute dysfunction of Starr-Edwards mitral prostheses are recorded. The patients presented with sudden dysponea 4 to 18 months after apparently successful mitral valve replacement. The prosthetic valve dysfunction was caused by thrombus on the bare metal cage of the prosthesis. No warning thromboembolic phenomena had been recorded. Urgent replacement of the valve resulted in the survival of one patient. Images PMID:5576532

  17. Thirty-Seven-Year Durability of a Starr-Edwards Aortic Prosthesis

    PubMed Central

    Ozkokeli, Mehmet; Ates, Mehmet; Ekinci, Abdurrahman; Akcar, Murat

    2005-01-01

    We report the case of a patient who was diagnosed with prosthetic valve endocarditis caused by Staphylococcus aureus. He had undergone aortic valve replacement with a Starr-Edwards prosthesis 37 years earlier. Because of uncontrolled infection despite antibiotic treatment, the patient underwent successful surgical replacement of the prosthetic valve. PMID:15902834

  18. Cloth destruction and haemolysis with totally cloth-covered Starr-Edwards prostheses

    PubMed Central

    Schottenfeld, M.; Wisheart, J. D.; Ross, J. K.; Lincoln, J. C. R.; Ross, D. N.

    1971-01-01

    Four cases are described in which totally cloth-covered Starr-Edwards valves (model 2300) had to be removed. All were causing significant haemolysis, two in the absence of a peripheral leak. The principal operative finding was destruction of the Dacron covering the struts. Following replacement of these prostheses there was complete resolution of signs and symptoms. The possible causes of haemolysis and consequences of cloth destruction are discussed. Images PMID:5576531

  19. Ball valve extractor

    DOEpatents

    Herndon, Charles; Brown, Roger A.

    2002-01-01

    An apparatus and process for removing a ball valve is provided. The ball valve removal tool provides a handle sliding along the length of a shaft. One end of the shaft is secured within an interior cavity of a ball valve while the opposite end of the shaft defines a stop member. By providing a manual sliding force to the handle, the handle impacts the stop member and transmits the force to the ball valve. The direction of the force is along the shaft of the removal tool and disengages the ball valve from the ball valve housing.

  20. Thrombo-embolic complications of the cloth-covered Starr-Edwards prostheses No. 2300 aortic and No. 6300 mitral

    PubMed Central

    Cleland, J.; Molloy, P. J.

    1973-01-01

    The thrombo-embolic complications of the cloth-covered Starr-Edwards prostheses No. 2300 aortic and No. 6300 mitral followed for an average of 14 months in 155 patients are reviewed. There was a high incidence of early fatal and disabling thrombo-embolus in patients having mitral valve replacement. Late emboli were more common after aortic valve replacement. Anticoagulant control was unsatisfactory and not without hazards. PMID:4685210

  1. Quartz ball valve

    NASA Technical Reports Server (NTRS)

    Goetz, C.; Ingle, W. M. (Inventor)

    1980-01-01

    A ball valve particularly suited for use in the handling of highly corrosive fluids is described. It is characterized by a valve housing formed of communicating segments of quartz tubing, a pair of communicating sockets disposed in coaxial alignment with selected segments of tubing for establishing a pair of inlet ports communicating with a common outlet port, a ball formed of quartz material supported for displacement between the sockets and configured to be received alternately thereby, and a valve actuator including a rod attached to the ball for selectively displacing the ball relative to each of the sockets for controlling fluid flow through the inlet ports.

  2. Stemless Ball Valve

    NASA Technical Reports Server (NTRS)

    Burgess, Robert K.; Yakos, David; Walthall, Bryan

    2012-01-01

    This invention utilizes a new method of opening and closing a ball valve. Instead of rotating the ball with a perpendicular stem (as is the case with standard ball valves), the ball is rotated around a fixed axis by two guide pins. This innovation eliminates the leak point that is present in all standard ball valves due to the penetration of an actuation stem through the valve body. The VOST (Venturi Off-Set-Technology) valve has been developed for commercial applications. The standard version of the valve consists of an off-set venturi flow path through the valve. This path is split at the narrowest portion of the venturi, allowing the section upstream from the venturi to be rotated. As this rotation takes place, the venturi becomes restricted as one face rotates with respect to the other, eventually closing off the flow path. A spring-loaded seal made of resilient material is embedded in the upstream face of the valve, making a leak-proof seal between the faces; thus a valve is formed. The spring-loaded lip seal is the only seal that can provide a class six, or bubble-tight, seal against the opposite face of the valve. Tearing action of the seal by high-velocity gas on this early design required relocation of the seal to the downstream face of the valve. In the stemless embodiment of this valve, inner and outer magnetic cartridges are employed to transfer mechanical torque from the outside of the valve to the inside without the use of a stem. This eliminates the leak path caused by the valve stems in standard valves because the stems penetrate through the bodies of these valves.

  3. Stemless ball valve

    NASA Technical Reports Server (NTRS)

    Burgess, Kevin (Inventor); Yakos, David (Inventor); Walthall, Bryan (Inventor)

    2011-01-01

    A stemless ball valve comprising two flanges and a ball with a channel, two axis pins and two travel pins. One end of each axis and travel pin is fixedly attached to the ball, and the other end of each axis pin is lodged into a notch in the first or second flange such that the axis pin is allowed to rotate in the notch. The guide sleeve comprises two channels, and one end of each travel pin is situated within one of the two channels in the guide sleeve. An outer magnetic cartridge causes the inner magnetic cartridge and guide sleeve to rotate, and when the guide sleeve rotates, the travel pins move up and down within the channels in the guide sleeve. The movement of the travel pins within the channels in the guide sleeve causes the ball to rotate, thereby opening and closing the ball valve.

  4. Stemless ball valve

    NASA Technical Reports Server (NTRS)

    Burgess, Kevin (Inventor); Yakos, David (Inventor); Walthall, Bryan (Inventor)

    2012-01-01

    A stemless ball valve comprising: a right flange; left flange; ball with an axis pin and two travel pins; ball seal on either side of the ball; guide sleeve with inner walls comprising two channels; cartridge guide holder; inner magnetic cartridge; and outer magnetic cartridge. The ball is situated inside of the guide sleeve, and a travel pin is located in each of the two channels. The guide sleeve is situated inside of the cartridge guide holder, which is located adjacent to and outside of the inner magnetic cartridge and secured to the inner magnetic cartridge such that when the inner magnetic cartridge rotates, the cartridge guide holder also rotates. The cartridge guide holder is secured to the guide sleeve such that when the cartridge guide holder rotates, the travel pins move within the channels in the inner walls of the guide sleeve, thereby causing the ball to rotate.

  5. The phonocardiogram in a partially detached mitral (Starr-Edwards) prosthesis

    PubMed Central

    Raj, M. V. Jeeva; Clarke, C. R. A.; Fleming, H. A.

    1975-01-01

    Phonocardiographic evidence of extreme variability of the time interval between the aortic sound (A2) and the opening click (OC) with intermittent absence of the OC of a partially detached mitral prosthesis of the Starr-Edwards type has not hitherto been reported. This case illustrates the diagnostic use of phonocardiography in a malfunctioning mitral Starr-Edwards prosthesis. ImagesFig. 1Fig. 2 PMID:1197179

  6. Twenty-Two-Year Experience with Aortic Valve Replacement

    PubMed Central

    Pilegaard, Hans K.; Lund, Ole; Nielsen, Torsten T.; Magnussen, Karin; Knudsen, Mary A.; Albrechtsen, Ole K.

    1991-01-01

    From 1965 through 1986, 817 patients underwent aortic valve replacement at our institution. Six hundred forty-five patients received Starr-Edwards ball valves, including 286 Silastic ball valves (Models 1200/1260), 165 cloth-covered caged-ball prostheses (Models 2300/2310/2320), and 194 track-valve prostheses (Model 2400). In contrast, 172 patients received disc-valve prostheses, including 126 St. Jude Medical aortic bi-leaflet disc valves, 32 Lillehei-Kaster pivoting disc valves, and 14 Björk-Shiley valves (6 convexoconcave and 8 monostrut). With respect to preoperative data, the 2 groups were comparable, with the following differences. The Starr-Edwards group included 1) more men (77% versus 51%; p < 0.0001); 2) a significantly older patient population (59 ± 10 years versus 56 ± 15 years; p < 0.0001); 3) more patients in New York Heart Association functional class III or IV (72% versus 65%; p < 0.01); 4) fewer patients with angina pectoris as a limiting symptom (20% versus 36%; p < 0.0001); and 5) patients who tended to receive larger prostheses (26 ± 2 mm versus 23 ± 3 mm, p < 0.0001). The overall 10-year survival rate ± standard error was 59% ± 2% for patients receiving Starr-Edwards valves and 63% ± 6% for those with disc valves. The linearized complication rates (expressed as percentage per patient-year ± standard error) for the Starr-Edwards and disc-valve groups, respectively, were 2.0% ± 0.2% and 1.4% ± 0.5% for thromboembolism, 2.1% ± 0.2% and 3.9% ± 0.8% for Coumadin-related hemorrhage, 0.5% ± 0.1% and 0.3% ± 0.2% for endocarditis, 0.3% ± 0.1% and 0.7% ± 0.3% for other prosthesis-related complications, and 4.8% ± 0.1% and 6.4% ± 1.0% for all complications together. There were no instances of thrombotic occlusion or mechanical failure. After the 6th postoperative year, no thromboembolic events were encountered in patients with a Silastic ball valve; the 15-year freedom from thromboembolic events was 89%. Cox regression analysis showed

  7. A piezoelectrically actuated ball valve

    NASA Technical Reports Server (NTRS)

    Erwin, L. R.; Schwartz, H. W.; Teitelbaum, B. R.

    1972-01-01

    Bimorph strip composed of two layers of poled piezoelectric ceramic material closes and opens valve. Strip performs like capacitator, allowing initial inrush of current when valve is energized and then only small leakage current flows as valve remains energized.

  8. Advances in prosthetic heart valves: fluid mechanics of aortic valve designs.

    PubMed

    Yoganathan, A P; Woo, Y R; Sung, H W; Jones, M

    1988-04-01

    The in vitro hemodynamic characteristics of a variety of mechanical and tissue heart valve designs used during the past two decades were investigated in the aortic position under pulsatile flow conditions. The following valve designs were studied: Starr-Edwards ball and cage (model 1260), Björk-Shiley tilting disc (convexo-concave model), Medtronic-Hall tilting disc, St. Jude Medical bileaflet, Carpentier-Edwards porcine and pericardial (models 2625, 2650 and 2900), Hancock porcine (models 250 and 410) and Ionescu-Shiley standard pericardial. The Starr-Edward ball and cage, Björk-Shiley tilting disc, Carpentier-Edwards porcine (model 2625) and Ionescu-Shiley standard pericardial valves were designed prior to 1975, while the Medtronic-Hall tilting disc, St. Jude Medical bileaflet, Hancock porcine (model 250), Hancock II porcine (model 410), Carpentier-Edwards porcine (model 2650) and Carpentier-Edwards pericardial (model 2900) valves were designed after 1975. The pressure drop results indicated that the valves designed prior to 1975 had performance indices of 0.30 to 0.45, whereas the valves designed after 1975 had performance indices of 0.40 to 0.70. The regurgitant volumes were higher for the mechanical designs (5.0 to 11.0 cm3/beat) compared to the tissue bioprostheses (1.0 to 5.0 cm3/beat). Two-dimensional laser Doppler anemometry studies indicated that the valves designed after 1975 tended to create more centralized flow fields, with reduced levels of turbulent shear stresses. However, none of the current valve designs is ideal: they all create areas of stasis and/or regions of low velocity reverse flow; and regions of elevated turbulent shear stresses that are capable of causing sub-lethal and/or lethal damage to the formed elements of blood.

  9. Whitey SCHe Ball Valves Provide Test Port Isolation

    SciTech Connect

    MISKA, C.R.

    2000-10-19

    These valves are 1/4-inch ball valves fabricated of 316 stainless steel. Packing is TFE (standard). They are used as normally closed isolation valves for test ports in the SCHe System between the gage root valve and the pressure indicator.

  10. Whitey SCHe Ball Valves Provide Test Port Isolation

    SciTech Connect

    MISKA, C.R.

    2000-09-15

    These valves are 1/4 inch ball valves fabricated of 316 stainless steel. Packing is TFE (standard). They are used as normally closed isolation valves for test ports in the SCHe System between the gage root valve and the pressure indicator.

  11. Hemodynamic and hemolytic features of the St. Jude Medical valve prostheses.

    PubMed

    Sezai, Y; Umeda, S; Okazaki, T; Okamoto, I; Rikukawa, H; Shiono, M

    1984-01-01

    We performed valvular replacement in 86 cases (108 valves, 43 males, 43 females) from July 1978 to July 1981 with St. Jude Medical valves which utilize two discs made of pyrolytic carbon and employ a bileaflet central opening system. Ages ranged from 13 to 68 years (average 42.3). For all cases in this study, we performed anti-coagulant therapy. The incidence of thromboembolic complication was zero. With regard to postoperative clinical evaluation on valve function and chronic hemolysis, we compared the cases of St. Jude Medical valves with those of Starr-Edwards (S.E.) valves (aortic: Model 2320, mitral: Model 6400), Carpentier-Edwards (C.E.) valves and cases of open mitral commissurotomy. As for valve function such as left atrioventricular diastolic pressure gradient, mitral effective orifice area both at rest and on exercise, the St. Jude Medical valve yielded best results. Next was the C.E. and third was the S.E. The results of the St. Jude Medical valve group and those of the open mitral commissurotomy group were equivalent. In comparison with ball type cardiac valve prostheses and bioprostheses, the St. Jude Medical valve has excellent hemodynamic characteristic. Concerning hemolysis, the St. Jude Medical was below only the C.E., however the degree of hemolysis was so low that the St. Jude Medical valve holds great promise as central flow mechanical valve prostheses.

  12. 16. DETAIL SHOWING LIQUID OXYGEN TANK FOURTEENINCH BALL VALVE. Looking ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    16. DETAIL SHOWING LIQUID OXYGEN TANK FOURTEEN-INCH BALL VALVE. Looking southwest. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  13. 17. DETAIL, FOURTEENINCH LIQUID OXYGEN BALL VALVE. Looking south southeast. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    17. DETAIL, FOURTEEN-INCH LIQUID OXYGEN BALL VALVE. Looking south southeast. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  14. A Lifting Ball Valve for cryogenic fluid applications

    NASA Astrophysics Data System (ADS)

    Cardin, Joseph M.; Reinicke, Robert H.; Bruneau, Stephen D.

    1993-11-01

    Marotta Scientific Controls, Inc. has designed a Lifting Ball Valve (LBV) capable of both flow modulation and tight shutoff for cryogenic and other applications. The LBV features a thin-walled visor valving element that lifts off the seal with near axial motion before rotating completely out of the flow path. This is accomplished with a simple, robust mechanism that minimizes cost and weight. Conventional spherical rotating seats ar plagued by leakage due to 'scuffing' as the seal and seat slide against one another while opening. Cryogenic valves, which typically utilize plastic seals, are particularly susceptible to this type of damage. The seat in the LBV lifts off the seal without 'scuffing' making it immune to this failure mode. In addition, the LBV lifting mechanism is capable of applying the very high seating loads required to seal at cryogenic temperatures. These features make the LBV ideally suited for cryogenic valve applications. Another major feature of the LBV is the fact that the visor rotates completely out of the flow path. This allows for a smaller, lighter valve for a given flow capacity, especially for line sizes above one inch. The LBV is operated by a highly integrated 'wetted' DC brushless motor. The motor rotor is 'wetted' ion that it is immersed in the fluid. To ensure compatibility, the motor rotor is encased in a thin-walled CRES weldment. The motor stator is outside the fluid containment weldment and therefore is not in direct contact with the fluid. To preclude the potential for external leakage there are no static or dynamic seals or bellows across the pressure boundary. The power required to do the work of operating the valving mechanism is transmitted across the pressure boundary by electromagnetic interaction between the motor rotor and the stator. Commutation of the motor is accomplished using the output of a special 'wetted' resolver. This paper describes the design, operation, and element testing of the LBV.

  15. Space Shuttle Orbital Maneuvering Subsystem (OMS) Engine Propellant Leakage Ball-Valve Shaft Seals

    NASA Technical Reports Server (NTRS)

    Lueders, Kathy; Buntain, Nick; Fries, Joseph (Technical Monitor)

    1999-01-01

    Evidence of propellant leakage across ball-valve shaft seals has been noted during the disassembly of five flight engines and one test engine at the NASA Lyndon B. Johnson Space Center, White Sands Test Facility. Based on data collected during the disassembly of these five engines, the consequences of propellant leakage across the ball-valve shaft seals can be divided into four primary areas of concern: Damage to the ball-valve pinion shafts, damage to sleeved bearings inside the ball-valve and actuator assemblies, degradation of the synthetic rubber o-rings used in the actuator assemblies, and corrosion and degradation to the interior of the actuator assemblies. The exact time at which leakage across the ball-valve shaft seals occurs has not been determined, however, the leakage most likely occurs during engine firings when, depending on the specification used, ball-valve cavity pressures range as high as 453 to 550 psia. This potential pressure range for the ball-valve cavities greatly exceeds the acceptance leakage test pressure of 332 psia. Since redesign and replacement of the ball-valve shaft seals is unlikely, the near term solution to prevent damage that occurs from shaft-seal leakage is to implement a routine overhaul and maintenance program for engines in the fleet. Recommended repair, verification, and possible preventative maintenance measures are discussed in the paper.

  16. Current status of valve replacement in children.

    PubMed

    Schaff, H V; Danielson, G K

    1986-01-01

    Management of valve diseases in children demands an eclectic approach by the surgeon. Whenever possible, valve function should be restored by repair rather than prosthetic replacement. Recent evidence firmly demonstrates that there are accelerated calcification and degeneration of porcine heterografts in children, especially in the aortic and mitral positions. For this reason, we reserve the use of heterograft prostheses for the right atrioventricular position and for conduits from the right ventricle to the pulmonary artery. Such patients are observed carefully for signs of valve degeneration. Long-term followup of the Starr-Edwards prosthesis in children demonstrates excellent durability and a thromboembolic rate that is equal to or lower than that found in adult patients. Hemodynamic properties of the Starr-Edwards valve are adequate even in the smallest size used in infants and have allowed children to reach early adolescence at which time valve re-replacement with an adult-sized prosthesis is possible. Intermediate-term experience with the Bjork-Shiley valve in children has also been favorable. At present we continue to use systemic anticoagulation with warfarin in all children with mechanical prostheses. PMID:3742534

  17. Downhole tool for use with a ball and seat traveling valve for a fluid pump

    SciTech Connect

    Spears, H.L.

    1989-07-18

    This paper describes a downhole tool for use with a ball and seat travelling valve associated with a movable plunger, having upper and lower ends, for pumping well fluids. It comprises: an upper housing; a lower housing adapted to be associated with the upper end of the plunger; and means for causing relative movement between the upper and lower housings and abutment of the upper housing against the lower housing to impart a bumping force to the plunger during the downward movement of the plunger, whereby the ball is moved from its seat to permit the passage of well fluids through the travelling valve.

  18. System for remotely servicing a top loading captive ball valve

    DOEpatents

    Berry, Stephen M.; Porter, Matthew L.

    1996-01-01

    An attachment for facilitating servicing of a valve, the valve including: an assembly composed of a valve seat defining a flow path, a flow control member movable relative to the valve seat for blocking or unblocking the valve seat, and a control device including a stem coupled to the flow control member and operable for moving the flow control member relative to the valve seat; a housing for receiving the assembly, the housing having an opening via which the assembly can be removed from, and installed in, the housing, and the housing having a plurality of threaded studs which surround the opening and project away from the housing; a valve housing cover for closing and sealing the opening in the housing, the cover having a first bore for passage of the stem of the control device when the assembly is installed in the housing and a plurality of second bores each located for passage of a respective stud when the cover closes the opening in the housing. A plurality of threaded nuts are engageable with the studs for securing the cover to the housing when the cover closes the opening in the housing, wherein the attachment comprises: a plurality of nut guide devices removable from the housing and each operatively associated with a respective stud for retaining a respective nut and guiding the respective nut into alignment with the respective stud to enable the respective nut to be rotated into engagement with the respective stud; and aligning the nut guide devices with the studs.

  19. System for remotely servicing a top loading captive ball valve

    DOEpatents

    Berry, S.M.; Porter, M.L.

    1996-06-25

    An attachment for facilitating servicing of a valve is disclosed including: an assembly composed of a valve seat defining a flow path, a flow control member movable relative to the valve seat for blocking or unblocking the valve seat, and a control device including a stem coupled to the flow control member and operable for moving the flow control member relative to the valve seat; a housing for receiving the assembly, the housing having an opening via which the assembly can be removed from, and installed in, the housing, and the housing having a plurality of threaded studs which surround the opening and project away from the housing; a valve housing cover for closing and sealing the opening in the housing, the cover having a first bore for passage of the stem of the control device when the assembly is installed in the housing and a plurality of second bores each located for passage of a respective stud when the cover closes the opening in the housing. A plurality of threaded nuts are engageable with the studs for securing the cover to the housing when the cover closes the opening in the housing, wherein the attachment comprises: a plurality of nut guide devices removable from the housing and each operatively associated with a respective stud for retaining a respective nut and guiding the respective nut into alignment with the respective stud to enable the respective nut to be rotated into engagement with the respective stud; and aligning the nut guide devices with the studs. 7 figs.

  20. Examination of a 15. 24-cm ball valve from the Morgantown Energy Technology Center Lock Hopper Valve Testing and Development Project: failure analysis report

    SciTech Connect

    Danyluk, S.; Diercks, D.; Dragel, G.M.

    1980-01-01

    A 15.24-cm ball valve failed while undergoing tests in simulated lock hopper service. The valve stem developed severe torsional deformation after 3134 cycles while handling limestone fines, and a replacement stem also exhibited deformation after an additional 124 cycles. The test was terminated at that point due to excessive valve leakage. Inspection of the valve at METC revealed large quantities of limestone fines packed between the valve ball and the body, and also revealed chipping of the chromium oxide coating around the valve stem slot. The valve seats, ball, and stem were sent to the Materials Science Division of Argonne National Laboratory for further examination. A visual examination at Argonne confirmed the general features seen at METC, and also revealed chipping of the coating on the overspray region of one of the valve seats. It was determined that the torque required to cause gross plastic deformation of the valve stem was well below that which the actuator was capable of applying in the valve test at METC. A microstructural examination of sections from each of the two valve seats indicated no significant debonding of the coating, and an independent analysis by the Linde Division of Union Carbide Corp. found the coating to meet the manufacturer's specifications. Variations in coating thickness on the valve ball of the order of 50% were observed using eddy-current techniques, but absolute values for the coating thicknesses were not obtained.Hardness readings on the valve-seat coating material were found to be slightly below the specified values, but the difference did not appear to be significant.

  1. Understanding how brass ball valves passing certification testing can cause elevated lead in water when installed.

    PubMed

    Triantafyllidou, Simoni; Raetz, Meredith; Parks, Jeffrey; Edwards, Marc

    2012-06-15

    The lead leaching potential of new brass plumbing devices has come under scrutiny as a significant source of lead in drinking water (>300 μg/L) of new buildings around the world. Experiments were conducted using ball valves that were sold as certified and known to have caused problems in practice, in order to better understand how installed products could create such problems, even if they passed "leaching tests" such as National Sanitation Foundation (NSF) Standard 61 Section 8. Diffusion of lead from within the device into water when installed can increase lead leaching by orders of magnitude relative to results of NSF testing, which once only required exposure of very small volumes of water within the device. "Normalization" of the lead-in-water result tended to produce estimates of lead concentration that were much lower than actual lead measured at the tap. Finally, the presence of flux could also dramatically increase lead leaching, whereas high water velocity had relatively little effect.

  2. Understanding how brass ball valves passing certification testing can cause elevated lead in water when installed.

    PubMed

    Triantafyllidou, Simoni; Raetz, Meredith; Parks, Jeffrey; Edwards, Marc

    2012-06-15

    The lead leaching potential of new brass plumbing devices has come under scrutiny as a significant source of lead in drinking water (>300 μg/L) of new buildings around the world. Experiments were conducted using ball valves that were sold as certified and known to have caused problems in practice, in order to better understand how installed products could create such problems, even if they passed "leaching tests" such as National Sanitation Foundation (NSF) Standard 61 Section 8. Diffusion of lead from within the device into water when installed can increase lead leaching by orders of magnitude relative to results of NSF testing, which once only required exposure of very small volumes of water within the device. "Normalization" of the lead-in-water result tended to produce estimates of lead concentration that were much lower than actual lead measured at the tap. Finally, the presence of flux could also dramatically increase lead leaching, whereas high water velocity had relatively little effect. PMID:22520861

  3. Safety check valve

    SciTech Connect

    Spears, H.L.

    1992-02-11

    This patent describes a safety check valve, for use with a pumping unit for petroleum fluids, the pumping unit including a polished rod and a stuffing box. It comprises: a valve housing having upper and lower ends and a central bore extending between the upper and lower ends and adapted to have the polished rod pass through the central bore; a ball seating surface associated with the central bore; a non-spring bias ball; a ball housing for the ball and associated with the valve housing; and means for moving the ball from the ball housing into the central bore upon the polished rod not being disposed in the central bore, including a ball receiving cavity associated with the ball housing, the ball hoising having first and second ends, the first end of the ball housing being in communication with the central bore of the valve housing, the second end being closed; the ball receiving cavity having a ball support surface upon which the ball may rest, when the ball is disposed in the ball receiving cavity, the ball support surface sloping downwardly toward the first end of the ball housing, whereby if the polished rod is not disposed within the central bore of the valve housing, the ball moves down the ball support surface, under the force of gravity, from the ball receiving cavity into the central bore and seats on the ball seating surface.

  4. The Effect of Pressure Ratio on Unsteady Fluid-Structure Interaction Characteristics of Ball Type Control Valve

    NASA Astrophysics Data System (ADS)

    Du, Yang; Tu, Shan; Wang, Hongjuan

    Two-way sequential fluid-structure interaction method was used to analyze and discuss the characteristics of unsteady fluid-structure interaction of the complex flow channel of a steam turbine ball type control valve. Research indicates that when the pressure ratio changes as a sine wave, its flow rate occurs a sine wave change, and the maximum flow rate value of 57.46kg•s-1 occurs in the minimum pressure ratio condition. The longitudinal force of the structure domain decreases with the reduction of the pressure ratio, and points to the opposite direction of the flow. The lateral force increases with the decrease of the pressure ratio, and points to the opposite direction of the flow. The maximum value of deformation and force of the structure domain changes consistently with the pressure ratio fluctuation. The maximum value of the structure domain stress is 28.67MPa, which is far less than the yield strength of the structure material, and the maximum deformation value is 3.25um.

  5. Adjustable safety relief valve

    SciTech Connect

    Taylor, W.L.

    1990-06-12

    This patent describes a pressure relief valve having a relief set pressure. It comprises: a valve body having a fluid inlet and outlet, a spherical, metal valve seat associated with the inlet and a valve member comprising at least a portion of a spherical,metal ball attached to a ball holding element, the valve member being biased against the valve seat and thus providing a metal-to-metal seal preventing the passage of fluids past the valve seat when the fluid pressure in the inlet is below the relief pressure setting of the valve.

  6. VALVE

    DOEpatents

    Arkelyan, A.M.; Rickard, C.L.

    1962-04-17

    A gate valve for controlling the flow of fluid in separate concentric ducts or channels by means of a single valve is described. In one position, the valve sealing discs engage opposed sets of concentric ducts leading to the concentric pipes defining the flow channels to block flow therethrough. In another position, the discs are withdrawn from engagement with the opposed ducts and at the same time a bridging section is interposed therebetween to define concentric paths coextensive with and connecting the opposed ducts to facilitate flow therebetween. A wedge block arrangement is employed with each sealing disc to enable it to engage the ducts. The wedge block arrangement also facilitates unobstructcd withdrawal of the discs out of the intervening space between the sets of ducts. (AEC)

  7. Valve

    DOEpatents

    Cho, Nakwon

    1980-01-01

    A positive acting valve suitable for operation in a corrosive environment is provided. The valve includes a hollow valve body defining an open-ended bore for receiving two, axially aligned, spaced-apart, cylindrical inserts. One insert, designated the seat insert, terminates inside the valve body in an annular face which lies within plane normal to the axis of the two inserts. An elastomeric O-ring seal is disposed in a groove extending about the annular face. The other insert, designated the wedge insert, terminates inside the valve body in at least two surfaces oppositely inclined with respect to each other and with respect to a plane normal to the axis of the two inserts. An elongated reciprocable gate, movable between the two inserts along a path normal to the axis of the two inserts, has a first flat face portion disposed adjacent and parallel to the annular face of the seat insert. The gate has a second face portion opposite to the first face portion provided with at least two oppositely inclined surfaces for mating with respective inclined surfaces of the wedge insert. An opening is provided through the gate which registers with a flow passage through the two inserts when the valve is open. Interaction of the respective inclined surfaces of the gate and wedge insert act to force the first flat face portion of the gate against the O-ring seal in the seat insert at the limits of gate displacement where it reaches its respective fully open and fully closed positions.

  8. Quartz ball value

    NASA Technical Reports Server (NTRS)

    Goetz, C.; Ingle, W. M.

    1979-01-01

    Quartz ball valve consisting of two quartz joints sealed back-to-back and seated in quartz sockets perform at temperatures of up to 1,250 C and in corrosive chemical environments without contamination or degradation.

  9. ULTRA HIGH VACUUM VALVE

    DOEpatents

    Fry, W.A.

    1962-05-29

    A valve for high vacuum applications such as the CStellarator where chamber pressures as low as 2 x 10/sup -10/ mm Hg are necessary is designed with a line-of-sight path through the valve for visual inspection of the contents of reactants in such chambers. The valve comprises a turnable resilient metal ball having an aperture therethrough, means for selectively turning the ball to rotate the axis of its line-of-sight path, and soft, deformable opposing orifices that are movable relatively toward said ball to seal with opposite ball surfaces upon said movement of said axis of said line-of-sight path. The valve also includes a bellows seal connected between said orifices and internal actuating means that eliminates the requirement for gasketed turnable valve closing stems. (AEC)

  10. Valve for abrasive material

    DOEpatents

    Gardner, Harold S.

    1982-01-01

    A ball valve assembly for controlling the flow of abrasive particulates including an enlarged section at the bore inlet and an enlarged section at the bore outlet. A refractory ceramic annular deflector is positioned in each of the enlarged sections, substantially extending the useful life of the valve.

  11. Ball clay

    USGS Publications Warehouse

    Virta, R.L.

    2001-01-01

    Part of the 2000 annual review of the industrial minerals sector. A general overview of the ball clay industry is provided. In 2000, sales of ball clay reached record levels, with sanitary ware and tile applications accounting for the largest sales. Ball clay production, consumption, prices, foreign trade, and industry news are summarized. The outlook for the ball clay industry is also outlined.

  12. 241-AN-A valve pit manifold valves and position indication acceptance test procedure

    SciTech Connect

    VANDYKE, D.W.

    1999-08-25

    This document describes the method used to test design criteria for gear actuated ball valves installed in 241-AN-A Valve Pit located at 200E Tank Farms. The purpose of this procedure is to demonstrate the following: Equipment is properly installed, labeled, and documented on As-Built drawings; New Manifold Valves in the 241-AN-A Valve Pit are fully operable using the handwheel of the valve operators; New valve position indicators on the valve operators will show correct valve positions; New valve position switches will function properly; and New valve locking devices function properly.

  13. 241-AN-B valve pit manifold valves and position indication acceptance test procedure

    SciTech Connect

    VANDYKE, D.W.

    1999-08-25

    This document describes the method used to test design criteria for gear actuated ball valves installed in 241-AN-B Valve Pit located at 200E Tank Farms. The purpose of this procedure is to demonstrate the following: Equipment is properly installed, labeled, and documented on As-Built drawings; New Manifold Valves in the 241-AN-B Valve Pit are fully operable using the handwheel of the valve operators; New valve position indicators on the valve operators will show correct valve positions; New valve position switches will function properly; and New valve locking devices function properly.

  14. Ball clay

    USGS Publications Warehouse

    Virta, Robert L.

    2010-01-01

    The article reports on the global market performance of ball clay in 2009 and presents an outlook for its 2010 performance. Several companies mined ball call in the country including Old Hickey Clay Co., Kentucky-Tennessee Clay Co., and H.C. Spinks Clay Co. Information on the decline in ball clay imports and exports is also presented.

  15. Ball clay

    USGS Publications Warehouse

    Virta, R.L.

    2011-01-01

    The article discusses the latest developments in the global ball clay mining industry, particularly in the U.S., as of June 2011. It cites several firms that are involved in ball clay mining in the U.S., including HC Spins Clay Co. Inc., the Imerys Group and Old Hickory Clay Co. Among the products made from ball clay are ceramic tiles, sanitaryware, as well as fillers, extenders and binders.

  16. Energy conservation with automatic flow control valves

    SciTech Connect

    Phillips, D.

    1984-12-01

    Automatic flow control valves are offered in a wide range of sizes starting at 1/2 in. with flow rates of 0.5 gpm and up. They are also provided with materials and end connections to meet virtually any fan-coil system requirement. Among these are copper sweat type valves; ductile iron threaded valves; male/female threaded brass valves; and combination flow control/ball valves with union ends.

  17. Fast closing valve

    DOEpatents

    Hanson, Clark L.

    1984-01-10

    A valve is provided for protecting the high vacuum of a particle accelera in the event of air leakage, wherein the valve provides an axially symmetrical passage to avoid disturbance of the partical beam during normal operation, and yet enables very rapid and tight closure of the beam-carrying pipe in the event of air leakage. The valve includes a ball member (30) which can rotate between a first position wherein a bore (32) in the member is aligned with the beam pipe, and a second position out of line with the pipe. A seal member (38) is flexibly sealed to the pipe, and has a seal end which can move tightly against the ball member after the bore has rotated out of line with the pipe, to thereby assure that the seal member does not retard rapid rotation of the ball valve member. The ball valve member can be rapidly rotated by a conductive arm (40) fixed to it and which is rotated by the discharge of a capacitor bank through coils (44, 45) located adjacent to the arm.

  18. Ball clay

    USGS Publications Warehouse

    Virta, R.L.

    2013-01-01

    Four companies — H.C. Spinks Clay Co., Inc., Imerys, Old Hickory Clay Co. and Unimin Corp. — mined ball clay in five U.S. states in 2012. Production, on the basis of preliminary data, was 900 kt (992,000 st), with an estimated value of $42.3 million. This was a slight increase in tonnage from 886 kt (977,000 st), with a value of $40.9 million in 2011. Tennessee was the leading ball clay producing state, with 63 percent of domestic production, followed by Texas, Mississippi, Kentucky and Indiana. Reported ball clay production from Indiana probably was fire clay rather than ball clay. About 69 percent of total ball clay production was airfloat, 20 percent was crude and 11 percent was water-slurried.

  19. Valve-"Health"-Monitoring System

    NASA Technical Reports Server (NTRS)

    Jensen, Scott L.; Drouant, George J.

    2009-01-01

    A system that includes sensors and data acquisition, wireless data-communication, and data-processing subsystems has been developed as a means of both real-time and historical tracking of information indicative of deterioration in the mechanical integrity and performance of a highgeared ball valve or a linearly actuated valve that operates at a temperature between cryogenic and ambient.

  20. Ball lightning

    NASA Astrophysics Data System (ADS)

    Stenhoff, Mark

    Ball lightning is alleged by some to be a rare atmospheric phenomenon usually associated with thunderstorms, while others hold that it does not exist. This controversy has continued for centuries. This study comprises a critical evaluation of evidence for the existence of ball lightning. An historical review of the controversy is first presented, giving a chronological account of developments in ball lightning theories and of important observations alleged to be of the phenomenon. Other phenomena which might be mistaken for ball lightning are then subjected to a more detailed study than has hitherto been published, and the means by which such misidentifications could be recognized areestablished. A discussion of psychological and perceptual aspects indicates that descriptions could not always be taken at face value, and that many accounts of alleged ball lightning would be expected to contain substantial inaccuracies. The original intention to evaluate cases of alleged ball lightning already published in scientific journals was abandoned because there was no standardisation of information content, and because the majority of reports contained insufficient information for evaluation. Many reports had been written in a style which indicated an assumption that ball lightning was the cause of the event. Approximately 200 unpublished reports were therefore collected and subjected to evaluation. It was found that the majority of reports of alleged ball lightning could be explained by other means, and there was only a very small residue of reports which could not easily be thus explained. A large proportion of the reports could be attributed to corona discharge effects such as St Elmo's fire, or by familiar effects of conventional linear lightning. The validity of many previously published statistical studies of ball lightning was shown to be doubtful. The thesis concludes with a comparitive discussion of the merits and demerits of some of the diverse physical models

  1. Whitey SCHE Gauge and Root Valves

    SciTech Connect

    VAN KATWIJK, C.

    2000-06-21

    These valves are 1/2 inch ball valves fabricated of 316 stainless steel. Packing is TFE (standard). They are used as isolation valves for pressure instrumentation in the SCHe System between the helium bottle supply manifolds and safety class helium pressure instrumentation, and in lower pressure SCHe supply line.

  2. Whitey SCHE Gauge and Root Valves

    SciTech Connect

    MISKA, C.R.

    2000-09-03

    These valves are 1/2 inch ball valves fabricated of 316 stainless steel. Packing is TFE (standard). They are used as isolation valves for pressure instrumentation in the SCHe System between the helium bottle supply manifolds and safety class helium pressure instrumentation, and in lower pressure SCHe supply line.

  3. Whitey SCHE Gauge and Root Valves

    SciTech Connect

    MISKA, C.R.

    2000-09-11

    These valves are 1/2 inch ball valves fabricated of 316 stainless steel. Packing is TFE (standard). They are used as isolation valves for pressure instrumentation in the SCHa System between the helium bottle supply manifolds and safety class helium pressure instrumentation, and in lower pressure SCHa supply line.

  4. Conical Seat Shut-Off Valve

    NASA Technical Reports Server (NTRS)

    Farner, Bruce

    2013-01-01

    A moveable valve for controlling flow of a pressurized working fluid was designed. This valve consists of a hollow, moveable floating piston pressed against a stationary solid seat, and can use the working fluid to seal the valve. This open/closed, novel valve is able to use metal-to-metal seats, without requiring seat sliding action; therefore there are no associated damaging effects. During use, existing standard high-pressure ball valve seats tend to become damaged during rotation of the ball. Additionally, forces acting on the ball and stem create large amounts of friction. The combination of these effects can lead to system failure. In an attempt to reduce damaging effects and seat failures, soft seats in the ball valve have been eliminated; however, the sliding action of the ball across the highly loaded seat still tends to scratch the seat, causing failure. Also, in order to operate, ball valves require the use of large actuators. Positioning the metal-to-metal seats requires more loading, which tends to increase the size of the required actuator, and can also lead to other failures in other areas such as the stem and bearing mechanisms, thus increasing cost and maintenance. This novel non-sliding seat surface valve allows metal-to-metal seats without the damaging effects that can lead to failure, and enables large seating forces without damaging the valve. Additionally, this valve design, even when used with large, high-pressure applications, does not require large conventional valve actuators and the valve stem itself is eliminated. Actuation is achieved with the use of a small, simple solenoid valve. This design also eliminates the need for many seals used with existing ball valve and globe valve designs, which commonly cause failure, too. This, coupled with the elimination of the valve stem and conventional valve actuator, improves valve reliability and seat life. Other mechanical liftoff seats have been designed; however, they have only resulted in

  5. Golf Ball

    NASA Technical Reports Server (NTRS)

    1998-01-01

    The Ultra 500 Series golf balls, introduced in 1995 by Wilson Sporting Goods Company, has 500 dimples arranged in a pattern of 60 spherical triangles. The design employs NASA's aerodynamics technology analysis of air loads of the tank and Shuttle orbiter that was performed under the Space Shuttle External Tank program. According to Wilson, this technology provides 'the most symmetrical ball surface available, sustaining initial velocity longer and producing the most stable ball flight for unmatched accuracy and distance.' The dimples are in three sizes, shapes and depths mathematically positioned for the best effect. The selection of dimples and their placement optimizes the interaction of opposing forces of lift and drag. Large dimples reduce air drag, enhance lift, and maintain spin for distance. Small dimples prevent excessive lift that destabilizes the ball flight and the medium size dimples blend the other two.

  6. Holy balls!

    NASA Astrophysics Data System (ADS)

    Truscott, Tadd; Belden, Jesse

    2011-11-01

    Why can some balls walk on water while others cannot? We investigate the rebound dynamics of elastic spheres impacting on a free-surface. Several variables determine whether or not a sphere will bounce when impacting a free-surface including velocity, impact angle, size and elasticity. Stiff elastic spheres, such as a racquetball, successfully skip at low impact angles and high velocities, but tend not to bounce when the impact angle becomes too large. However, the more compliant Waboba (WAter BOuncing BAll) bounces marvelously even at very high impact angles. Unlike a stiffer ball, the Waboba flattens out quickly as it is forming a cavity. The cavity lip forms a ramp and the flattened ball then skips off the water surface. We demonstrate how this phenomenon surprisingly resembles a skipping stone. Using high-speed video we explore the rebound dynamics for various values of elasticity, velocity, angle and size and determine when an object will bounce off the water surface.

  7. Ball clay

    USGS Publications Warehouse

    Virta, R.L.

    2007-01-01

    The article offers information on ball clay. Among the companies that mine ball clay in the U.S. are H.C. Spinks Clay, Kentucky-Tennessee Clay and Old Hickory Clay. In 2006, an estimated 1.2 million tons of the mineral was sold or used domestically and exported. Forty-percent of the total sales is accounted for ceramic floor and wall tile followed by sanitaryware and miscellaneous ceramics. Its average value was $ 45 per ton in 2006.

  8. Ball feeder for replenishing evaporator feed

    DOEpatents

    Felde, David K.; McKoon, Robert H.

    1993-01-01

    Vapor source material such as uranium, which is to be dropped into a melt in an evaporator, is made into many balls of identical diameters and placed inside a container. An elongated sloping pipe is connected to the container and leads to the evaporator such that these balls can travel sequentially therealong by gravity. A metering valve in this pipe for passing these balls one at a time is opened in response to a signal when it is ascertained by a detector that there is a ball ready to be passed. A gate in the pipe near the evaporator momentarily stops the motion of the traveling ball and is then opened to allow the ball drop into the melt at a reduced speed.

  9. Ball feeder for replenishing evaporator feed

    DOEpatents

    Felde, D.K.; McKoon, R.H.

    1993-03-23

    Vapor source material such as uranium, which is to be dropped into a melt in an evaporator, is made into many balls of identical diameters and placed inside a container. An elongated sloping pipe is connected to the container and leads to the evaporator such that these balls can travel sequentially therealong by gravity. A metering valve in this pipe for passing these balls one at a time is opened in response to a signal when it is ascertained by a detector that there is a ball ready to be passed. A gate in the pipe near the evaporator momentarily stops the motion of the traveling ball and is then opened to allow the ball drop into the melt at a reduced speed.

  10. Electromechanically Actuated Valve for Controlling Flow Rate

    NASA Technical Reports Server (NTRS)

    Patterson, Paul

    2007-01-01

    A proposed valve for controlling the rate of flow of a fluid would include an electric-motor-driven ball-screw mechanism for adjusting the seating element of the valve to any position between fully closed and fully open. The motor would be of a type that can be electronically controlled to rotate to a specified angular position and to rotate at a specified rate, and the ball screw would enable accurate linear positioning of the seating element as a function of angular position of the motor. Hence, the proposed valve would enable fine electronic control of the rate of flow and the rate of change of flow. The uniqueness of this valve lies in a high degree of integration of the actuation mechanism with the flow-control components into a single, relatively compact unit. A notable feature of this integration is that in addition to being a major part of the actuation mechanism, the ball screw would also be a flow-control component: the ball screw would be hollow so as to contain part of the main flow passage, and one end of the ball screw would be the main seating valve element. The relationships among the components of the valve are best understood by reference to the figure, which presents meridional cross sections of the valve in the fully closed and fully open positions. The motor would be supported by a bracket bolted to the valve body. By means of gears or pulleys and a timing belt, motor drive would be transmitted to a sleeve that would rotate on bearings in the valve body. A ball nut inside the sleeve would be made to rotate with the sleeve by use of a key. The ball screw would pass through and engage the ball nut. A key would prevent rotation of the ball screw in the valve body while allowing the ball screw to translate axially when driven by the ball nut. The outer surface of the ball screw would be threaded only in a mid-length region: the end regions of the outer surface of the ball screw would be polished so that they could act as dynamic sealing surfaces

  11. CFD analysis of a ball check microvalve

    NASA Astrophysics Data System (ADS)

    Cǎlimǎnescu, Ioan; Dumitrache, Constantin L.; Grigorescu, Lucian

    2015-02-01

    The microvalves with balls as seen before are used in many applications and their behaviour in terms of fluid dynamics mainly at their opening time (when as demonstrated the ball is bouncing up and down altering the flow parameters) is of a paramount importance. The present study is focused on a micro check ball valve circulating a fluid air-like (with the same constant proprieties). The CFD model is taking into account a transitory zone of functioning from zero time when the pressure inside a "tank" is reaching the opening pressure of the valve, to the final step 0.05 seconds when the ball is stabilizing after bouncing up and down. The geometry of the valve with dimensions in μm is given below (the model is comprising a "slice" of 5 μm thickness extracted from the entire valve. In this paper by using advanced numeric techniques, the behavior of the valve in its transitory opening stage was studied with credible and useful results for further optimisation studies.

  12. Standing valve

    SciTech Connect

    Coleman, S.B.

    1990-08-28

    This patent discusses an apparatus for removing fluids from a wellbore. It comprises a valve housing fixedly secured to a wellbore tubing string, the housing having perforations and a valve seating surface; a valve stem alignment guide secured to the valve housing; a valve stem adapted for movement in the valve stem alignment guide; and a valve seating device attached to the valve stem and capable of contacting the valve seating surface, thereby preventing fluid flow through the valve housing and past the valve seating surface when the seating device and valve seating surface are in contact.

  13. Science of Ball Lightning (Fire Ball)

    NASA Astrophysics Data System (ADS)

    Ohtsuki, Yoshi-Hiko

    1989-08-01

    The Table of Contents for the full book PDF is as follows: * Organizing Committee * Preface * Ball Lightning -- The Continuing Challenge * Hungarian Ball Lightning Observations in 1987 * Nature of Ball Lightning in Japan * Phenomenological and Psychological Analysis of 150 Austrian Ball Lightning Reports * Physical Problems and Physical Properties of Ball Lightning * Statistical Analysis of the Ball Lightning Properties * A Fluid-Dynamical Model for Ball Lightning and Bead Lightning * The Lifetime of Hill's Vortex * Electrical and Radiative Properties of Ball Lightning * The Candle Flame as a Model of Ball Lightning * A Model for Ball Lightning * The High-Temperature Physico-Chemical Processes in the Lightning Storm Atmosphere (A Physico-Chemical Model of Ball Lightning) * New Approach to Ball Lightning * A Calculation of Electric Field of Ball Lightning * The Physical Explanation to the UFO over Xinjiang, Northern West China * Electric Reconnection, Critical Ionization Velocity, Ponderomotive Force, and Their Applications to Triggered and Ball Lightning * The PLASMAK™ Configuration and Ball Lightning * Experimental Research on Ball Lightning * Performance of High-Voltage Test Facility Designed for Investigation of Ball Lightning * List of Participants

  14. Safety valve

    DOEpatents

    Bergman, Ulf C.

    1984-01-01

    The safety valve contains a resilient gland to be held between a valve seat and a valve member and is secured to the valve member by a sleeve surrounding the end of the valve member adjacent to the valve seat. The sleeve is movable relative to the valve member through a limited axial distance and a gap exists between said valve member and said sleeve.

  15. Combined pressure regulator and shutoff valve

    NASA Technical Reports Server (NTRS)

    Koch, E. F. (Inventor)

    1974-01-01

    A remotely operable pressure regulator and shutoff valve particularly suited for achieving high resolution and flow control, and positive shutoff is described. The valve is characterized by a spring-loaded ball coaxially aligned with a fluid port to be sealed, a spring-loaded pintle extended through the port into engagement with the ball, for controlling the position, a spring-loaded diaphragm for controlling the position of the pintle, and an axially displaceable spring supported by a movable stop which, in turn, is repositioned by a selectively operable stepper motor. Thus, the pressure-response characteristics for the valve can be varied through a selective repositioning of the stop.

  16. Improve pumping efficiency with PSZ ceramic balls

    SciTech Connect

    Brothers, J. )

    1989-04-01

    partially stabilized zirconia (PSZ) ceramic balls used today in downhole pumps improve both the efficiency and run time of sucker rod pumping systems. Recent field tests showed the balls increased the average run time of downhole pumps by 440%. While there are other types of stabilizers, only magnesia PSZ is appropriate for downhole pumps. The more commonly found alloy balls and carbide balls have been found to deform and not seal under these conditions. PSZ is most notable for its resistance to breaking from impact. A nonductile material, it will make a perfect seal on the seat despite any impact, enhancing its use in fluid pound situations. Other PSZ applications in downhole pumps and related equipment include plunger inserts, discharge inserts, plunger rings, choke parts, pressure relief valve components, and triplex pump plungers.

  17. Ball clay

    USGS Publications Warehouse

    Virta, R.L.

    2012-01-01

    Four companies — H.C. Spinks Clay Co., Inc., Imerys Group, Old Hickory Clay Co., and Unimin Corp. — mined ball clay in four states in 2011. Production, on the basis of preliminary data, was 940 kt (1.04 million st) with an estimated value of $44.2 million. This is a 3-percent increase in tonnage from 912 kt (1.01 million st) with a value of $41.3 million that was produced in 2010. Tennessee was the leading producing state with 63 percent of domestic production, followed by Texas, Mississippi and Kentucky. About 69 percent of production was airfloat, 20 percent was crude and 11 percent was water-slurried.

  18. Bouncing Balls that Spin

    ERIC Educational Resources Information Center

    Knipp, Peter

    2008-01-01

    When a ball bounces elastically against a floor, the vertical component (v[subscript y]) of the velocity of the ball's mass-center changes sign. This is a special case of the elastic collision of two balls (i.e., two objects, neither of which is much more massive than the other), in which case the balls' post-collision relative velocity (=…

  19. Plug valve

    DOEpatents

    Wordin, John J.

    1989-01-01

    An improved plug valve wherein a novel shape for the valve plug and valve chamber provide mating surfaces for improved wear characteristics. The novel shape of the valve plug is a frustum of a body of revolution of a curved known as a tractrix, a solid shape otherwise known as a peudosphere.

  20. Check valve

    DOEpatents

    Upton, Hubert Allen; Garcia, Pablo

    1999-08-24

    A check valve for use in a GDCS of a nuclear reactor and having a motor driven disk including a rotatable armature for rotating the check valve disk over its entire range of motion is described. In one embodiment, the check valve includes a valve body having a coolant flow channel extending therethrough. The coolant flow channel includes an inlet end and an outlet end. A valve body seat is located on an inner surface of the valve body. The check valve further includes a disk assembly, sometimes referred to as the motor driven disc, having a counterweight and a disk shaped valve. The disk valve includes a disk base having a seat for seating with the valve body seat. The disk assembly further includes a first hinge pin member which extends at least partially through the disk assembly and is engaged to the disk. The disk valve is rotatable relative to the first hinge pin member. The check valve also includes a motor having a stator frame with a stator bore therein. An armature is rotatably positioned within the stator bore and the armature is coupled to the disk valve to cause the disk valve to rotate about its full range of motion.

  1. Check valve

    DOEpatents

    Upton, H.A.; Garcia, P.

    1999-08-24

    A check valve for use in a GDCS of a nuclear reactor and having a motor driven disk including a rotatable armature for rotating the check valve disk over its entire range of motion is described. In one embodiment, the check valve includes a valve body having a coolant flow channel extending therethrough. The coolant flow channel includes an inlet end and an outlet end. A valve body seat is located on an inner surface of the valve body. The check valve further includes a disk assembly, sometimes referred to as the motor driven disc, having a counterweight and a disk shaped valve. The disk valve includes a disk base having a seat for seating with the valve body seat. The disk assembly further includes a first hinge pin member which extends at least partially through the disk assembly and is engaged to the disk. The disk valve is rotatable relative to the first hinge pin member. The check valve also includes a motor having a stator frame with a stator bore therein. An armature is rotatably positioned within the stator bore and the armature is coupled to the disk valve to cause the disk valve to rotate about its full range of motion. 5 figs.

  2. FLUID MECHANICS OF ARTIFICIAL HEART VALVES

    PubMed Central

    Dasi, Lakshmi P; Simon, Helene A; Sucosky, Philippe; Yoganathan, Ajit P

    2009-01-01

    SUMMARY 1. Artificial heart valves have been in use for over five decades to replace diseased heart valves. Since the first heart valve replacement performed with a caged-ball valve, more than 50 valve designs have been developed, differing principally in valve geometry, number of leaflets and material. To date, all artificial heart valves are plagued with complications associated with haemolysis, coagulation for mechanical heart valves and leaflet tearing for tissue-based valve prosthesis. For mechanical heart valves, these complications are believed to be associated with non-physiological blood flow patterns. 2. In the present review, we provide a bird’s-eye view of fluid mechanics for the major artificial heart valve types and highlight how the engineering approach has shaped this rapidly diversifying area of research. 3. Mechanical heart valve designs have evolved significantly, with the most recent designs providing relatively superior haemodynamics with very low aerodynamic resistance. However, high shearing of blood cells and platelets still pose significant design challenges and patients must undergo life-long anticoagulation therapy. Bioprosthetic or tissue valves do not require anticoagulants due to their distinct similarity to the native valve geometry and haemodynamics, but many of these valves fail structurally within the first 10–15 years of implantation. 4. These shortcomings have directed present and future research in three main directions in attempts to design superior artificial valves: (i) engineering living tissue heart valves; (ii) development of advanced computational tools; and (iii) blood experiments to establish the link between flow and blood damage. PMID:19220329

  3. Having a Ball with Fitness Balls

    ERIC Educational Resources Information Center

    McNulty, Betty

    2011-01-01

    Fitness programs can be greatly enhanced with the addition of fitness balls. They are a fun, challenging, economical, and safe way to incorporate a cardiovascular, strength, and stretching program for all fitness levels in a physical education setting. The use of these balls has become more popular during the last decade, and their benefits and…

  4. The Goldenrod Ball Gall

    ERIC Educational Resources Information Center

    Fischer, Richard B.

    1974-01-01

    The paper presents a generalized life history of the goldenrod ball gall, a ball-shaped swelling found almost exclusively on the Canada goldenrod, Solidago canadensis, and caused by a peacock fly know as Eurosta soldiaginis. (KM)

  5. Valve Disease

    MedlinePlus

    ... the need for heart valve surgery. Percutaneous Interventions Balloon valvuloplasty is a procedure that may be used ... procedure works on valves in the same way balloon angioplasty does on the arteries. Like angioplasty, it ...

  6. Ball Screw Actuator Including a Compliant Ball Screw Stop

    NASA Technical Reports Server (NTRS)

    Wingett, Paul T. (Inventor); Hanlon, Casey (Inventor)

    2015-01-01

    An actuator includes a ball nut, a ball screw, and a ball screw stop. The ball nut is adapted to receive an input torque and in response rotates and supplies a drive force. The ball screw extends through the ball nut and has a first end and a second end. The ball screw receives the drive force from the ball nut and in response selectively translates between a retract position and a extend position. The ball screw stop is mounted on the ball screw proximate the first end to translate therewith. The ball screw stop engages the ball nut when the ball screw is in the extend position, translates, with compliance, a predetermined distance toward the first end upon engaging the ball nut, and prevents further rotation of the ball screw upon translating the predetermined distance.

  7. Fizz-Ball Fizzics

    ERIC Educational Resources Information Center

    Moinester, Murray; Gerland, Lars; Liger-Belair, Gerard; Ocherashvili, Aharon

    2012-01-01

    We describe the fluid dynamics principles governing the up-down oscillatory cycling of a bubble-covered, low-density, low-mass ball of material (referred to henceforth as a "fizz-ball") immersed inside a glass of bubbling (super-saturated) carbonated liquid. The bubbles serve to desaturate the liquid of excess CO[subscript 2]. The fizz-ball acts…

  8. Heart valve surgery

    MedlinePlus

    Valve replacement; Valve repair; Heart valve prosthesis; Mechanical valves, Prosthetic valves ... place. The main types of new valves are: Mechanical -- made of man-made materials, such as metal ( ...

  9. Balls on the Lawn

    NASA Astrophysics Data System (ADS)

    Mallows, Colin L.; Shapiro, Lou

    1999-03-01

    In the "tennis ball" problem we are given successive pairs of balls numbered (1,2), (3,4),... At each stage we throw one ball out of the window. After n stages some set of n balls is on the lawn. We find a generating function and a closed formula for the sequence 3, 23, 131, 664, 3166, 14545, 65187, 287060, 1247690,..., the n-th term of which gives the sum over all possible arrangements of the total of the numbers on the balls on the lawn. The problem has connections with "bicolored Motzkin paths" and the ballot problem.

  10. Fast valve

    DOEpatents

    Van Dyke, William J.

    1992-01-01

    A fast valve is disclosed that can close on the order of 7 milliseconds. It is closed by the force of a compressed air spring with the moving parts of the valve designed to be of very light weight and the valve gate being of wedge shaped with O-ring sealed faces to provide sealing contact without metal to metal contact. The combination of the O-ring seal and an air cushion create a soft final movement of the valve closure to prevent the fast air acting valve from having a harsh closing.

  11. Fast valve

    DOEpatents

    Van Dyke, W.J.

    1992-04-07

    A fast valve is disclosed that can close on the order of 7 milliseconds. It is closed by the force of a compressed air spring with the moving parts of the valve designed to be of very light weight and the valve gate being of wedge shaped with O-ring sealed faces to provide sealing contact without metal to metal contact. The combination of the O-ring seal and an air cushion create a soft final movement of the valve closure to prevent the fast air acting valve from having a harsh closing. 4 figs.

  12. Space Shuttle OMS engine valve technology. [Orbital Maneuvering System

    NASA Technical Reports Server (NTRS)

    Wichmann, H.

    1974-01-01

    Valve technology program to determine shutoff valve concepts suitable for the Orbital Maneuvering System (OMS) engine of the Space Shuttle. The tradeoff studies selected the electric torque motor operated dual poppet and ball valves as the most desirable valve concepts for the OMS Engine Shutoff Valve. A prototype of one of these concepts was built and subjected to a design verification program. A number of unique features were designed to include the required contamination insensitivity, operating fluid compatibility, decontamination capability, minimum maintenance requirement and long service life capability.

  13. Free-floating left atrial ball thrombus after mitral valve replacement with patent coronary artery bypass grafts: successful removal by a right minithoracotomy approach without aortic cross-clamp.

    PubMed

    Hisatomi, Kazuki; Hashizume, Koji; Tanigawa, Kazuyoshi; Miura, Takashi; Matsukuma, Seiji; Yokose, Shogo; Kitamura, Tessho; Shimada, Takashi; Eishi, Kiyoyuki

    2016-06-01

    A free-floating thrombus in the left atrium without attachment to either the atrial wall or the mitral valve is extremely rare. We describe a case in a 79-year-old woman with chronic atrial fibrillation and a recent stroke who had undergone mitral valve replacement 25 years previously and coronary artery bypass grafting 5 years previously. Redo cardiac surgery represents a clinical challenge due to a higher rate of peri-operative morbidity and mortality. Median re-sternotomy can be particularly difficult in patients with functioning coronary artery grafts, where the risk of graft injury is a significant concern. Prompt surgical intervention was carried out, and to avoid the challenge of re-sternotomy in this patient with two prior thoracotomies, we successfully removed the thrombus by a right minithoracotomy approach without aortic cross-clamping. There was no postoperative occurrence of a new stroke or aggravation of the pre-existing stroke.

  14. Depressurization valve

    DOEpatents

    Skoda, G.I.

    1989-03-28

    A depressurization valve for use in relieving completely the pressure in a simplified boiling water reactor is disclosed. The normally closed and sealed valve is provided with a valve body defining a conduit from an outlet of a manifold from the reactor through a valve seat. A closing valve disk is configured for fitting to the valve seat to normally close the valve. The seat below the disk is provided with a radially extending annulus extending a short distance into the aperture defined by the seat. The disk is correspondingly provided with a longitudinally extending annulus that extends downwardly through the aperture defined by the seat towards the high pressure side of the valve body. A ring shaped membrane is endlessly welded to the seat annulus and to the disk annulus. The membrane is conformed over the confronted surface of the seat and disk in a C-sectioned configuration to seal the depressurization valve against the possibility of weeping. The disk is held to the closed position by an elongate stem extending away from the high pressure side of the valve body. The stem has a flange configured integrally to the stem for bias by two springs. The first spring acts from a portion of the housing overlying the disk on the stem flange adjacent the disk. This spring urges the stem and attached disk away from the seat and thus will cause the valve to open at any pressure. A second spring-preferably of the Belleville variety-acts on a latch plate surrounding and freely moving relative to the end of the stem. This second spring overcomes the bias of the first spring and any pressure acting upon the disk. This Belleville spring maintains through its spring force the valve in the closed position. At the same time, the latch plate with its freedom of movement relative to the stem allows the stem to thermally expand during valve temperature excursion.

  15. The bounce of a ball

    NASA Astrophysics Data System (ADS)

    Cross, Rod

    1999-03-01

    In this paper, the dynamics of a bouncing ball is described for several common ball types having different bounce characteristics. Results are presented for a tennis ball, a baseball, a golf ball, a superball, a steel ball bearing, a plasticene ball, and a silly putty ball. The plasticene ball was studied as an extreme case of a ball with a low coefficient of restitution (in fact zero, since the collision is totally inelastic) and the silly putty ball was studied because it has unusual elastic properties. The first three balls were studied because of their significance in the physics of sports. For each ball, a dynamic hysteresis curve is presented to show how energy is lost during and after the collision. The measurement technique is quite simple, it is suited for undergraduate laboratory experiments, and it may provide a useful method to test and approve balls for major sporting events.

  16. Physics of ball sports

    NASA Astrophysics Data System (ADS)

    Cohen, C.; Clanet, C.

    2016-06-01

    Ball sports have been part of human history for thousands of years [1]. Nowadays, 13 of them are part of the Olympic games (badminton, basketball, beach volley, football/soccer, golf, handball, hockey, rugby, table tennis, tennis, volleyball, water polo, ice hockey). All these games differ by launcher (hand, club, racket, bat), ball (size, shape and mass), pitch size and number of players. These differences induce different ball velocities. Apart from the velocities and the way to maximize them, we discuss in this article the ball trajectories and their impact on the size of sports fields.

  17. Ball Bearing Mechanics

    NASA Technical Reports Server (NTRS)

    Hamrock, B. J.; Dowson, D.

    1981-01-01

    Load-deflection relationships for different types of elliptical contacts such as those found in a ball bearing are developed. Simplified expressions that allow quick calculations of deformation to be made simply from a knowledge of the applied load, the material properties, and the geometry of the contacting elements are presented. Ball bearings subjected to radial, thrust and combined ball loads are analyzed. A design criterion for fatigue life of ball bearings is developed. The section of a satisfactory lubricant, as well as describing systems that provide a constant flow of lubricant to the contact, is considered.

  18. Birth of ball lightning

    NASA Astrophysics Data System (ADS)

    Lowke, J. J.; Smith, D.; Nelson, K. E.; Crompton, R. W.; Murphy, A. B.

    2012-10-01

    Many observations of ball lightning report a ball of light, about 10 cm in diameter, moving at about walking speed, lasting up to 20 s and frequently existing inside of houses and even aeroplanes. The present paper reports detailed observations of the initiation or birth of ball lightning. In two cases, navigation crew of aircraft saw ball lightning form at the windscreen inside the cockpit of their planes. In the first case, the ball lightning occurred during a thunderstorm, with much lightning activity outside of the plane. In the second case, large "horns" of electrical corona were seen outside of the plane at the surface of the radome, just prior to the formation of the ball lightning. A third case reports ball lightning formed inside of a house, during a thunderstorm, at a closed glass window. It is proposed, based on two-dimensional calculations of electron and ion transport, that ball lightning in these cases is driven and formed by atmospheric ions impinging and collecting on the insulating surface of the glass or Perspex windows. This surface charge can produce electric fields inside of the cockpit or room sufficient to sustain an electric discharge. Charges of opposite sign to those outside of the window accumulate on the inside surface of the glass, leaving a ball of net charge moving inside of the cockpit or room to produce a pulsed discharge on a microsecond time scale.

  19. Ball Collision Experiments

    ERIC Educational Resources Information Center

    Cross, R.

    2015-01-01

    Experiments are described on collisions between two billiard balls and between a bat and a ball. The experiments are designed to extend a student's understanding of collision events and could be used either as a classroom demonstration or for a student project.

  20. Great balls of fire

    NASA Astrophysics Data System (ADS)

    Stenhoff, Mark; reader01; jjherrera

    2014-03-01

    In reply to the physicsworld.com news article “Burning soil fuels ball lightning” (9 January, http://ow.ly/tl8aO) on evidence that a burning core of soil acts as an energy source for ball lightning.

  1. Depressurization valve

    DOEpatents

    Skoda, George I.

    1989-01-01

    A depressurization valve for use in relieving completely the pressure in a simplified boiling water reactor is disclosed. The normally closed and sealed valve is provided with a valve body defining a conduit from an outlet of a manifold from the reactor through a valve seat. A closing valve disk is configured for fitting to the valve seat to normally close the valve. The seat below the disk is provided with a radially extending annulus extending a short distance into the aperture defined by the seat. The disk is correspondingly provided with a longitudinally extending annulus that extends downwardly through the aperture defined by the seat towards the high pressure side of the valve body. A ring shaped membrane is endlessly welded to the seat annulus and to the disk annulus. The membrane is conformed over the confronted surface of the seat and disk in a C-sectioned configuration to seal the depressurization valve against the possibility of weeping. The disk is held to the closed position by an elongate stem extending away from the high pressure side of the valve body. The stem has a flange configured integrally to the stem for bias by two springs. The first spring acts from a portion of the housing overlying the disk on the stem flange adjacent the disk. This spring urges the stem and attached disk away from the seat and thus will cause the valve to open at any pressure. A second spring--preferably of the Belleville variety--acts on a latch plate surrounding and freely moving relative to the end of the stem. This second spring overcomes the bias of the first spring and any pressure acting upon the disk. This Belleville spring maintains through its spring force the valve in the closed position. At the same time, the latch plate with its freedom of movement relative to the stem allows the stem to thermally expand during valve temperature excursion. The latch plate in surrounding the stem is limited in its outward movement by a boss attached to the stem at the end of

  2. Happy Balls, Unhappy Balls, and Newton's Cradle

    ERIC Educational Resources Information Center

    Kagan, David

    2010-01-01

    The intricacies of Newton's Cradle are well covered in the literature going as far back as the time of Newton! These discussions generally center on the highly elastic collisions of metal spheres. Thanks to the invention of happy and unhappy balls, you can build and study the interaction of less elastic systems (see Fig. 1).

  3. Happy Balls, Unhappy Balls, and Newton's Cradle

    NASA Astrophysics Data System (ADS)

    Kagan, David

    2010-03-01

    The intricacies of Newton's Cradle are well covered in the literature2-4 going as far back as the time of Newton!5 These discussions generally center on the highly elastic collisions of metal spheres. Thanks to the invention of happy and unhappy balls,6 you can build and study the interaction of less elastic systems (see Fig. 1).

  4. Valve assembly

    SciTech Connect

    Marshala, D.L.

    1986-12-16

    This patent describes a subsurface pump actuated by a reciprocatable sucker rod for producing well liquids from a subsurface reservoir involving a piston adapted to reciprocate within a cylinder immersed in the reservoir, the piston being provided with a traveling valve. The improvement described here comprises valve means connected to the sucker tod for lifting a body of fluid during upstrokes of the sucker rod, the valve means comprising: a barrel assembly having an internal bore and comprising: a lower barrel member; and an upper barrel assembly connected to the lower barrel and having a beveled seating surface with at least one fluid port therethrough.

  5. Nuclear radiation actuated valve

    DOEpatents

    Christiansen, David W.; Schively, Dixon P.

    1985-01-01

    A nuclear radiation actuated valve for a nuclear reactor. The valve has a valve first part (such as a valve rod with piston) and a valve second part (such as a valve tube surrounding the valve rod, with the valve tube having side slots surrounding the piston). Both valve parts have known nuclear radiation swelling characteristics. The valve's first part is positioned to receive nuclear radiation from the nuclear reactor's fuel region. The valve's second part is positioned so that its nuclear radiation induced swelling is different from that of the valve's first part. The valve's second part also is positioned so that the valve's first and second parts create a valve orifice which changes in size due to the different nuclear radiation caused swelling of the valve's first part compared to the valve's second part. The valve may be used in a nuclear reactor's core coolant system.

  6. Beware of the B(e)all valve: mistaken valve identity, 30-year survival, and valve replacement.

    PubMed

    Topaz, On; Rutherford, Molly S; Mackey-Bojack, Shannon; Polkampally, Pritam R; Topaz, Allyne; Prinz, Andreas; Szentpetery, Szabolcs

    2010-01-01

    Effective management of patients after the implantation of mechanical cardiac valves includes correct recognition of each valve and its related complications. Herein, we present the case of a patient who had undergone implantation of a floating-disc Beall-Surgitool mitral valve in 1976 and developed multiple valve-related complications. Over 30 years and in multiple medical centers, the device was mistakenly assumed to be a "ball" valve. The correct identification of the prosthesis led to the recognition of valvular failure, and the patient underwent its replacement with an On-X bileaflet carbon valve. Pathologic and microscopic examination of the explanted Beall valve showed massive pannus formation that extended over the sewing cuff on the atrial and ventricular side, preventing complete disc closure; disrupted fabric coating of the sewing ring, with exposure of the underlying metal; and a marked inflammatory reaction. We report one of the longest intervals on record between the implantation and replacement of a Beall-Surgitool valve.

  7. Compact Q-balls

    NASA Astrophysics Data System (ADS)

    Bazeia, D.; Losano, L.; Marques, M. A.; Menezes, R.; da Rocha, R.

    2016-07-01

    In this work we deal with non-topological solutions of the Q-ball type in two space-time dimensions, in models described by a single complex scalar field that engenders global symmetry. The main novelty is the presence of stable Q-balls solutions that live in a compact interval of the real line and appear from a family of models controlled by two distinct parameters. We find analytical solutions and study their charge and energy, and show how to control the parameters to make the Q-balls classically and quantum mechanically stable.

  8. Nanostructured and Conventional Cr2O3, TiO2, and TiO2-Cr2O3 Thermal-Sprayed Coatings for Metal-Seated Ball Valve Applications in Hydrometallurgy

    NASA Astrophysics Data System (ADS)

    Vernhes, Luc; Bekins, Craig; Lourdel, Nicolas; Poirier, Dominique; Lima, Rogerio S.; Li, Duanjie; Klemberg-Sapieha, Jolanta E.

    2016-06-01

    A detailed characterization project was undertaken by Velan, an international industrial valve designer and manufacturer, in collaboration with the National Research Council of Canada, Boucherville, and Polytechnique Montréal. The purpose was to assess the mechanical and tribological resistances of promising ceramic coatings for hydrometallurgy applications, including a novel n-TiO2-Cr2O3 blend. Hardness and shear strength were determined using microhardness indentation testers and universal tensile testing equipment. Wear resistance of the coatings under sliding wear, abrasion, and galling conditions were measured by standard pin-on-disk tests, abrasion tests, and custom-designed galling tests. The main result is that the synergy between Cr2O3 and n-TiO2 produced abrasion performance exceeding that of these materials alone. Also, an optimized balance between the hard and brittle Cr2O3 phases and the soft and ductile n-TiO2 phases resulted in higher abrasion, sliding, and galling resistance. The novel n-TiO2-Cr2O3 blend is therefore considered as a promising evolution of the current TiO2-Cr2O3 blend.

  9. Inserts Automatically Lubricate Ball Bearings

    NASA Technical Reports Server (NTRS)

    Hager, J. A.

    1983-01-01

    Inserts on ball-separator ring of ball bearings provide continuous film of lubricant on ball surfaces. Inserts are machined or molded. Small inserts in ball pockets provide steady supply of lubricant. Technique is utilized on equipment for which maintenance is often poor and lubrication interval is uncertain, such as household appliances, automobiles, and marine engines.

  10. Super Ball Bot

    NASA Video Gallery

    Tensegrity Robot: Child's Play or Space Tech? Super Ball Bot is an all-in-one landing and mobility platform based on tensegrity structures, allowing for lower-cost, and more reliable planetary miss...

  11. Introduction to ball bearings

    NASA Technical Reports Server (NTRS)

    Hamrock, B. J.; Dowson, D.

    1981-01-01

    The purpose of a ball bearing is to provide a relative positioning and rotational freedom while transmitting a load between two structures, usually a shaft and a housing. For high rotational speeds (e.g., in gyroscope ball bearings) the purpose can be expanded to include rotational freedom with practically no wear in the bearing. This condition can be achieved by separating the bearing parts with a coherent film of fluid known as an elastohydrodynamic film. This film can be maintained not only when the bearing carries the load on a shaft, but also when the bearing is preloaded to position the shaft to within micro- or nano-inch accuracy and stability. Background information on ball bearings is provided, different types of ball bearings and their geometry and kinematics are defined, bearing materials, manufacturing processes, and separators are discussed. It is assumed, for the purposes of analysis, that the bearing carries no load.

  12. Passive Ball Capture Joint

    NASA Technical Reports Server (NTRS)

    Cloyd, Richard A. (Inventor); Bryan, Thomas C. (Inventor)

    2003-01-01

    A passive ball capture joint has a sleeve with a plurality of bores distributed about a circumference thereof and formed therethrough at an acute angle relative to the sleeve's longitudinal axis. A spring-loaded retainer is slidingly fitted in each bore and is biased such that, if allowed, will extend at least partially into the sleeve to retain a ball therein. A ring, rotatably mounted about the bores, has an interior wall defining a plurality of shaped races that bear against the spring-loaded retainers. A mechanized rotational force producer is coupled to the ring. The ring can be rotated from a first position (that presses the retainers into the sleeve to lock the ball in place) to a second position (that allows the retainers to springback out of the sleeve to release the ball).

  13. Impact behavior of hollow balls

    NASA Astrophysics Data System (ADS)

    Cross, Rod

    2014-03-01

    Measurements are presented of the force acting on ping-pong and squash balls impacting on a force plate. Both ball types are hollow and have the same diameter but deform in very different ways. Ping pong balls are relatively stiff and buckle inwards at high impact speeds, while squash balls are softer and tend to squash or flatten. The buckling process generates a large-amplitude, high-frequency oscillation of the force acting on a ping-pong ball. Squash balls are initially very stiff before they soften, with the result that the force on the ball rises to about half its maximum value in the first 20 μs. Ping-pong balls have a high coefficient of restitution (COR), while squash balls have a low COR. Results for both ball types are interpreted in terms of additional experimental observations.

  14. Aerodynamics of sports balls

    NASA Technical Reports Server (NTRS)

    Mehta, R. D.

    1985-01-01

    Research data on the aerodynamic behavior of baseballs and cricket and golf balls are summarized. Cricket balls and baseballs are roughly the same size and mass but have different stitch patterns. Both are thrown to follow paths that avoid a batter's swing, paths that can curve if aerodynamic forces on the balls' surfaces are asymmetric. Smoke tracer wind tunnel tests and pressure taps have revealed that the unbalanced side forces are induced by tripping the boundary layer on the seam side and producing turbulence. More particularly, the greater pressures are perpendicular to the seam plane and only appear when the balls travel at velocities high enough so that the roughness length matches the seam heigh. The side forces, once tripped, will increase with spin velocity up to a cut-off point. The enhanced lift coefficient is produced by the Magnus effect. The more complex stitching on a baseball permits greater variations in the flight path curve and, in the case of a knuckleball, the unsteady flow effects. For golf balls, the dimples trip the boundary layer and the high spin rate produces a lift coefficient maximum of 0.5, compared to a baseball's maximum of 0.3. Thus, a golf ball travels far enough for gravitational forces to become important.

  15. Aerodynamics of sports balls

    NASA Astrophysics Data System (ADS)

    Mehta, R. D.

    Research data on the aerodynamic behavior of baseballs and cricket and golf balls are summarized. Cricket balls and baseballs are roughly the same size and mass but have different stitch patterns. Both are thrown to follow paths that avoid a batter's swing, paths that can curve if aerodynamic forces on the balls' surfaces are asymmetric. Smoke tracer wind tunnel tests and pressure taps have revealed that the unbalanced side forces are induced by tripping the boundary layer on the seam side and producing turbulence. More particularly, the greater pressures are perpendicular to the seam plane and only appear when the balls travel at velocities high enough so that the roughness length matches the seam heigh. The side forces, once tripped, will increase with spin velocity up to a cut-off point. The enhanced lift coefficient is produced by the Magnus effect. The more complex stitching on a baseball permits greater variations in the flight path curve and, in the case of a knuckleball, the unsteady flow effects. For golf balls, the dimples trip the boundary layer and the high spin rate produces a lift coefficient maximum of 0.5, compared to a baseball's maximum of 0.3. Thus, a golf ball travels far enough for gravitational forces to become important.

  16. Glovebox pressure relief and check valve

    SciTech Connect

    Blaedel, K.L.

    1986-03-17

    This device is a combined pressure relief valve and check valve providing overpressure protection and preventing back flow into an inert atmosphere enclosure. The pressure relief is embodied by a submerged vent line in a mercury reservior, the releif pressure being a function of the submerged depth. The pressure relief can be vented into an exhaust system and the relieving pressure is only slightly influenced by the varying pressure in the exhaust system. The check valve is embodied by a ball which floats on the mercury column and contacts a seat whenever vacuum exists within the glovebox enclosure. Alternatively, the check valve is embodied by a vertical column of mercury, the maximum back pressure being a function of the height of the column of mercury.

  17. 49 CFR 236.383 - Valve locks, valves, and valve magnets.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Valve locks, valves, and valve magnets. 236.383... Inspection and Tests § 236.383 Valve locks, valves, and valve magnets. Valve locks on valves of the non-cut-off type shall be tested at least once every three months, and valves and valve magnets shall...

  18. 49 CFR 236.383 - Valve locks, valves, and valve magnets.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Valve locks, valves, and valve magnets. 236.383... Inspection and Tests § 236.383 Valve locks, valves, and valve magnets. Valve locks on valves of the non-cut-off type shall be tested at least once every three months, and valves and valve magnets shall...

  19. 49 CFR 236.383 - Valve locks, valves, and valve magnets.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Valve locks, valves, and valve magnets. 236.383... Inspection and Tests § 236.383 Valve locks, valves, and valve magnets. Valve locks on valves of the non-cut-off type shall be tested at least once every three months, and valves and valve magnets shall...

  20. 49 CFR 236.383 - Valve locks, valves, and valve magnets.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Valve locks, valves, and valve magnets. 236.383... Inspection and Tests § 236.383 Valve locks, valves, and valve magnets. Valve locks on valves of the non-cut-off type shall be tested at least once every three months, and valves and valve magnets shall...

  1. 49 CFR 236.383 - Valve locks, valves, and valve magnets.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Valve locks, valves, and valve magnets. 236.383... Inspection and Tests § 236.383 Valve locks, valves, and valve magnets. Valve locks on valves of the non-cut-off type shall be tested at least once every three months, and valves and valve magnets shall...

  2. Piezoelectric valve

    DOEpatents

    Petrenko, Serhiy Fedorovich

    2013-01-15

    A motorized valve has a housing having an inlet and an outlet to be connected to a pipeline, a saddle connected with the housing, a turn plug having a rod, the turn plug cooperating with the saddle, and a drive for turning the valve body and formed as a piezoelectric drive, the piezoelectric drive including a piezoelectric generator of radially directed standing acoustic waves, which is connected with the housing and is connectable with a pulse current source, and a rotor operatively connected with the piezoelectric generator and kinematically connected with the rod of the turn plug so as to turn the turn plug when the rotor is actuated by the piezoelectric generator.

  3. Ball lightning burn.

    PubMed

    Selvaggi, Gennaro; Monstrey, Stan; von Heimburg, Dennis; Hamdi, Mustapha; Van Landuyt, Koen; Blondeel, Phillip

    2003-05-01

    Ball lightning is a rare physical phenomenon, which is not yet completely explained. It is similar to lightning but with different, peculiar characteristics. It can be considered a mix of fire and electricity, concentrated in a fireball with a diameter of 20-cm that most commonly appears suddenly, even in indoor conditions, during a thunderstorm. It moves quickly for several meters, can change direction, and ultimately disappears. During a great storm, a 28-year-old man and his 5-year-old daughter sustained burn wounds after ball lightning came from the outdoors through a chimney. These two patients demonstrated signs of fire and electrical injuries. The father, who lost consciousness, sustained superficial second-degree burn wounds bilaterally on the zygomatic area and deep second-degree burn wounds on his right hand (total body surface area, 4%). His daughter demonstrated superficial second-degree burn wounds on the left part of the face and deep second-degree and third-degree burn wounds (total body surface area, 30%) on the left neck, both upper arms, and the back. In this article, the authors report the first two cases of burn injuries resulting from ball lightning contact indoors. The literature on this rare phenomenon is reviewed to elucidate the nature of ball lightning. Emphasis is placed on the nature of injuries after ball lightning contact, the therapy used, and the long-term complications.

  4. Ball lightning burn.

    PubMed

    Selvaggi, Gennaro; Monstrey, Stan; von Heimburg, Dennis; Hamdi, Mustapha; Van Landuyt, Koen; Blondeel, Phillip

    2003-05-01

    Ball lightning is a rare physical phenomenon, which is not yet completely explained. It is similar to lightning but with different, peculiar characteristics. It can be considered a mix of fire and electricity, concentrated in a fireball with a diameter of 20-cm that most commonly appears suddenly, even in indoor conditions, during a thunderstorm. It moves quickly for several meters, can change direction, and ultimately disappears. During a great storm, a 28-year-old man and his 5-year-old daughter sustained burn wounds after ball lightning came from the outdoors through a chimney. These two patients demonstrated signs of fire and electrical injuries. The father, who lost consciousness, sustained superficial second-degree burn wounds bilaterally on the zygomatic area and deep second-degree burn wounds on his right hand (total body surface area, 4%). His daughter demonstrated superficial second-degree burn wounds on the left part of the face and deep second-degree and third-degree burn wounds (total body surface area, 30%) on the left neck, both upper arms, and the back. In this article, the authors report the first two cases of burn injuries resulting from ball lightning contact indoors. The literature on this rare phenomenon is reviewed to elucidate the nature of ball lightning. Emphasis is placed on the nature of injuries after ball lightning contact, the therapy used, and the long-term complications. PMID:12792547

  5. Gate valve and motor-operator research findings

    SciTech Connect

    Steele, R. Jr.; DeWall, K.G.; Watkins, J.C.; Russell, M.J.; Bramwell, D.

    1995-09-01

    This report provides an update on the valve research being sponsored by the US Nuclear Regulatory Commission (NRC) and conducted at the Idaho National Engineering Laboratory (INEL). The research addresses the need to provide assurance that motor-operated valves can perform their intended safety function, usually to open or close against specified (design basis) flow and pressure loads. This report describes several important developments: Two methods for estimating or bounding the design basis stem factor (in rising-stem valves), using data from tests less severe than design basis tests; a new correlation for evaluating the opening responses of gate valves and for predicting opening requirements; an extrapolation method that uses the results of a best effort flow test to estimate the design basis closing requirements of a gate valve that exhibits atypical responses (peak force occurs before flow isolation); and the extension of the original INEL closing correlation to include low- flow and low-pressure loads. The report also includes a general approach, presented in step-by-step format, for determining operating margins for rising-stem valves (gate valves and globe valves) as well as quarter-turn valves (ball valves and butterfly valves).

  6. Worcester 1 Inch Solenoid Actuated Gas Operated SCHe System Valves

    SciTech Connect

    MISKA, C.R.

    2000-09-03

    1 inch gas-operated full-port ball valves incorporate a solenoid and limit switches as integral parts of the actuator. These valves are normally open and fail safe to the open position (GOV-1*02 and 1*06 fail closed) to provide a flow path of helium gas to the MCO under helium purge and off-normal conditions when the MCO is isolated.

  7. Worcester 1 Inch Solenoid Actuated Gas Operated SCHe System Valves

    SciTech Connect

    VAN KATWIJK, C.

    2000-06-06

    1 inch Gas-operated full-port ball valves incorporate a solenoid and limit switches as integral parts of the actuator. These valves are normally open and fail safe to the open position (GOV-1*02 and 1*06 fail closed) to provide a flow path of helium gas to the MCO under helium purge and off-normal conditions when the MCO is isolated.

  8. Worcester 1 Inch Solenoid Actuated Gas Operated SCHe System Valves

    SciTech Connect

    MISKA, C.R.

    2000-11-13

    1 inch gas-operated full-port ball valves incorporate a solenoid and limit switches as integral parts of the actuator. These valves are normally open and fail safe to the open position (GOV-1*02 and 1*06 fail closed) to provide a flow path of helium gas to the MCO under helium purge and off-normal conditions when the MCO is isolated.

  9. Worcester 1 Inch Solenoid Actuated Gas Operated SCHe System Valves

    SciTech Connect

    VAN KATWIJK, C.

    2000-10-23

    1 inch Gas-operated full-port ball valves incorporate a solenoid and limit switches as integral parts of the actuator. These valves are normally open and fail safe to the open position (GOV-1*02 and 1*06 fall closed) to provide a flow path of helium gas to the MCO under helium purge and off-normal conditions when the MCO is isolated.

  10. Magnetically driven cold valve for {sup 4}He

    SciTech Connect

    Bueno, J.; Blaauwgeers, R.; Partapsing, R.; Taminiau, I.; Jochemsen, R.

    2006-08-15

    We have designed a low temperature valve for liquid helium, which uses a magnetic field gradient and a permanent magnet to close. For closing, it presses a small ruby ball onto a Torlon seat. We present a small valve that is easy to build and easily controlled via two wires. It has a fast response, reliable, and has the advantage that there is no dead volume change on closing and no additional helium line is required to operate.

  11. Hex ball torque test

    NASA Technical Reports Server (NTRS)

    Robinson, B. A.; Foster, C. L.

    1986-01-01

    A series of torque tests were performed on four flight-type hex ball universal joints in order to characterize and determine the actual load-carrying capability of this device. The universal joint is a part of manual actuation rods for scientific instruments within the Hubble Space Telescope. It was found that the hex ball will bind slightly during the initial load application. This binding did not affect the function of the universal joint, and the units would wear-in after a few additional loading cycles. The torsional yield load was approximately 50 ft-lb, and was consistent among the four test specimens. Also, the torque required to cause complete failure exceeded 80 ft-lb. It is concluded that the hex ball universal joint is suitable for its intended applications.

  12. Excess flow shutoff valve

    DOEpatents

    Kiffer, Micah S.; Tentarelli, Stephen Clyde

    2016-02-09

    Excess flow shutoff valve comprising a valve body, a valve plug, a partition, and an activation component where the valve plug, the partition, and activation component are disposed within the valve body. A suitable flow restriction is provided to create a pressure difference between the upstream end of the valve plug and the downstream end of the valve plug when fluid flows through the valve body. The pressure difference exceeds a target pressure difference needed to activate the activation component when fluid flow through the valve body is higher than a desired rate, and thereby closes the valve.

  13. Plasma valve

    DOEpatents

    Hershcovitch, Ady; Sharma, Sushil; Noonan, John; Rotela, Elbio; Khounsary, Ali

    2003-01-01

    A plasma valve includes a confinement channel and primary anode and cathode disposed therein. An ignition cathode is disposed adjacent the primary cathode. Power supplies are joined to the cathodes and anode for rapidly igniting and maintaining a plasma in the channel for preventing leakage of atmospheric pressure through the channel.

  14. OMS engine shutoff valve and actuation system design and evaluation. [for space shuttles

    NASA Technical Reports Server (NTRS)

    Wichmann, H.

    1974-01-01

    Shutoff valve and actuation system concepts that are most suitable for the Orbital Maneuvering Systems engine application were determined. Emphasis was placed on the ten year and 100 mission life requirement, propellant and propellant residue compatibility and weight. It was found that poppet or ball valves utilizing electric or electropneumatic actuation were most applicable. Preliminary design layouts of a number of valve and actuation concepts were prepared and analyzed to make the optimum concept selection. Pneumatic actuation systems were required to feature their own pneumatic supply so that for the quad redundant valve, it was necessary to include two pneumatic supply systems, one for each of the series legs of the quad redundant package. The requirement for the pneumatic package placed heavy reliability, weight, and maintenance penalties upon electropneumatic actuation systems. The two valve and actuation systems concepts selected featured electric torque motor operation and a poppet as well as a ball valve concept with a retractable seal.

  15. Balls and Spheres

    ERIC Educational Resources Information Center

    Szekely, George

    2011-01-01

    This article describes an art lesson that allows students to set up and collect sphere canvases. Spheres move art away from a rectangular canvas into a dimension that requires new planning and painting. From balls to many other spherical canvases that bounce, roll, float and fly, art experiences are envisioned by students. Even if adults recognize…

  16. Detonator-activated ball shutter

    DOEpatents

    McWilliams, R.A.; Holle, W.G. von.

    1983-08-16

    A detonator-activated ball shutter for closing an aperture in about 300[mu] seconds. The ball shutter containing an aperture through which light, etc., passes, is closed by firing a detonator which propels a projectile for rotating the ball shutter, thereby blocking passage through the aperture. 3 figs.

  17. Detonator-activated ball shutter

    DOEpatents

    McWilliams, Roy A.; von Holle, William G.

    1983-01-01

    A detonator-activated ball shutter for closing an aperture in about 300.mu. seconds. The ball shutter containing an aperture through which light, etc., passes, is closed by firing a detonator which propels a projectile for rotating the ball shutter, thereby blocking passage through the aperture.

  18. Visual Skills: Watch the Ball?

    ERIC Educational Resources Information Center

    Moen, Sue

    1989-01-01

    In tennis as well as in other racket/paddle sports, simply watching the ball does not guarantee success in hitting the ball to the desired location. Teachers and coaches should teach players to integrate available visual, spatial, and kinesthetic information. Several drills for good ball contact are outlined. (IAH)

  19. ELECTROSTRICTION VALVE

    DOEpatents

    Kippenhan, D.O.

    1962-09-25

    An accurately controlled, pulse gas valve is designed capable of delivering output pulses which vary in length from one-tenth millisecond to one second or more, repeated at intervals of a few milliseconds or- more. The pulsed gas valve comprises a column formed of barium titanate discs mounted in stacked relation and electrically connected in parallel, with means for applying voltage across the discs to cause them to expand and effect a mechanical elongation axially of the column. The column is mounted within an enclosure having an inlet port and an outlet port with an internal seat in communication with the outlet port, such that a plug secured to the end of the column will engage the seat of the outlet port to close the outlet port in response to the application of voltage is regulated by a conventional electronic timing circuit connected to the column. (AEC)

  20. VAPOR VALVE

    DOEpatents

    Wouters, L.F.

    1959-08-25

    Electromagnetically operated vapor valves are described for apparatus employed in the separation of isotopes or elements to control the flow of gaseous vapors between a vaporizing charge chamber and an ionizing chamber, The charge chamber and ionizing chamber are positioned in a magnetic field, and the flow of vapors through an orifice connecting the chambers is regulated by regulating the flow of current through a resilient metal strip rigidly mounted at one end and positioned in the magnetic field adjacent to the orifice.

  1. Aperture Valve for the Mars Organic Molecule Analyzer (MOMA)

    NASA Technical Reports Server (NTRS)

    Engler, Charles; Canham, John

    2014-01-01

    NASA's participation in the multi-nation ExoMars 2018 Rover mission includes a critical astrobiology Mass Spectrometer Instrument on the Rover called the Mars Organic Molecule Analyzer (MOMA). The Aperture Valve is a critical electromechanical valve used by the Mass Spectrometer to facilitate the transfer of ions from Martian soil to the Mass Spectrometer for analysis. The MOMA Aperture Valve development program will be discussed in terms of the initial valve design and subsequent improvements that resulted from prototype testing. The initial Aperture Valve concept seemed promising, based on calculations and perceived merits. However, performance results of this design were disappointing, due to delamination of TiN and DLC coatings applied to the titanium base metals, causing debris from the coatings to seize the valve. While peer reviews and design trade studies are important forums to vet a concept design, results from testing should not be underestimated. Despite the lack of development progress to meet requirements, valuable information from weakness discovered in the initial Valve design was used to develop a second, more robust Aperture Valve. Based on a check-ball design, the ETU / flight valve design resulted in significantly less surface area to create the seal. Moreover, PVD coatings were eliminated in favor of hardened, non-magnetic corrosion resistant alloys. Test results were impressive, with the valve achieving five orders of magnitude better sealing leak rate over end of life requirements. Cycle life was equally impressive, achieving 280,000 cycles without failure.

  2. Aperture Valve for the Mars Organic Molecule Analyzer (MOMA)

    NASA Technical Reports Server (NTRS)

    Engler, Charles D.; Canham, John S.

    2014-01-01

    NASA's participation in the multi-nation ExoMars 2018 Rover mission includes a critical astrobiology Mass Spectrometer Instrument on the Rover called the Mars Organic Molecule Analyzer (MOMA). The Aperture Valve is a critical electromechanical valve used by the Mass Spectrometer to facilitate the transfer of ions from Martian soil to the Mass Spectrometer for analysis. The MOMA Aperture Valve development program will be discussed in terms of the Initial valve design and subsequent improvements that resulted from prototype testing. The Initial Aperture Valve concept seemed promising, based on calculations and perceived merits. However, performance results of this design were disappointing, due to delamination of TiN and DLC coatings applied to the Titanium base metals, causing debris from the coatings to seize the valve. While peer reviews and design trade studies are important forums to vet a concept design, results from testing should not be underestimated. Despite the lack of development progress to meet requirements, valuable information from weakness discovered in the Initial Valve design was used to develop a second, more robust Aperture valve. Based on a check-ball design, the ETU /flight valve design resulted in significantly less surface area to create the seal. Moreover, PVD coatings were eliminated in favor of hardened, nonmagnetic corrosion resistant alloys. Test results were impressive, with the valve achieving five orders of magnitude better sealing leak rate over end of life requirements. Cycle life was equally impressive, achieving 280,000 cycles without failure.

  3. Aperture Valve for the Mars Organic Molecule Analyzer (MOMA)

    NASA Technical Reports Server (NTRS)

    Hakun, Claef F.; Engler, Charles D.; Barber, Willie E.; Canham, John S.

    2014-01-01

    NASA's participation in the multi-nation ExoMars 2018 Rover mission includes a critical astrobiology Mass Spectrometer Instrument on the Rover called the Mars Organic Molecule Analyzer (MOMA). The Aperture Valve is a critical electromechanical valve used by the Mass Spectrometer to facilitate the transfer of ions from Martian soil to the Mass Spectrometer for analysis. The MOMA Aperture Valve development program will be discussed in terms of the Initial valve design and subsequent improvements that resulted from prototype testing. The Initial Aperture Valve concept seemed promising, based on calculations and perceived merits. However, performance results of this design were disappointing, due to delamination of TiN and DLC coatings applied to the Titanium base metals, causing debris from the coatings to seize the valve. While peer reviews and design trade studies are important forums to vet a concept design, results from testing should not be underestimated.Despite the lack of development progress to meet requirements, valuable information from weakness discovered in the Initial Valve design was used to develop a second, more robust Aperture valve. Based on a check-ball design, the ETU flight valve design resulted in significantly less surface area to create the seal. Moreover, PVD coatings were eliminated in favor of hardened, nonmagnetic corrosion resistant alloys. Test results were impressive, with the valve achieving five orders of magnitude better sealing leak rate over end of life requirements. Cycle life was equally impressive, achieving 280,000 cycles without failure.

  4. Total prosthetic replacement of atrioventricular valves in the dog

    PubMed Central

    Den Otter, G.

    1968-01-01

    The free-floating cone and cage valve, described in a previous study as being successful as a substitute for the right atrioventricular valve, does not perform well when it is inserted in the mitral ostium. A tilting cone or disc was constructed and tested in a series of 15 dogs. This prosthesis gave excellent results in 12 animals. The reasons for its failure in the remaining three is discussed. The prosthesis presented has advantages over any ball and cage valve, mainly because of its smaller volume. Images PMID:5654076

  5. Mitral valve regurgitation

    MedlinePlus

    Mitral valve regurgitation; Mitral valve insufficiency; Heart mitral regurgitation; Valvular mitral regurgitation ... regurgitation is the most common type of heart valve disorder. Blood that flows between different chambers of ...

  6. Automatic shutoff valve

    NASA Technical Reports Server (NTRS)

    Hawkins, S. F.; Overbey, C. W.

    1980-01-01

    Cellulose-sponge disk absorbs incoming water and expands with enough force to shut valve. When water recedes, valve opens by squeezing sponge dry to its original size. This direct mechanical action is considered more reliable than solenoid valve.

  7. Aortic Valve Disease

    MedlinePlus

    ... Disease Tricuspid Valve Disease Cardiac Rhythm Disturbances Thoracic Aortic Aneurysm Pediatric and Congenital Heart Disease Heart abnormalities that ... Disease Tricuspid Valve Disease Cardiac Rhythm Disturbances Thoracic Aortic Aneurysm Aortic Valve Disease Overview The human heart has ...

  8. Development of Small-sized Fluid Control Valve with Self-holding Function Using Permanent Magnet

    NASA Astrophysics Data System (ADS)

    Akagi, Tetsuya; Dohta, Shujiro; Ueda, Hirofumi

    Recently, force feedback devices in virtual reality and power assisted nursing care systems have received much attention and active research. In such a control system, an actuator and a driving device such as a control valve are mounted on the human body. In this condition, the size and weight of the control valve become serious problems. At the same time, the valve should be operated with lower energy consumption because of using a limited electrical power. The typical electro magnetic solenoid valve drives its spool using a larger solenoid to open the valve. The complex construction of the valve for sealing makes its miniaturization and the fabrication of a low cost valve more difficult. In addition, the solenoid in the valve consumes more electrical power while the valve is kept opening. The purpose of our study is to develop a small-sized, lightweight, lower energy consumption and flexible control valve that can be safe enough to mount on the human body at a lower cost. In our pervious study, we proposed and tested the control valve that can open using a vibration motor. In this study, we propose and test a new type of fluid control valve with a self-holding function. The new valve uses a permanent magnet ball. It has a cylindrical magnet and two solenoids. The self-holding function of the valve is done as follows. When one side of the solenoid is stimulated by the current momentarily, the solenoid gives a repulsive force to the cylindrical magnet. The magnet moves toward the opposite side of the solenoid and is attracted to the iron core. Then, the magnet ball moves toward the cylindrical magnet and opens the orifice. The valve can keep open without electrical energy. As a result, the valve with the extremely lower energy consumption can be developed.

  9. Ball Lightning Investigations

    NASA Astrophysics Data System (ADS)

    Bychkov, V. L.; Nikitin, A. I.; Dijkhuis, G. C.

    Ball lightning (BL) researches' review and theoretical models of three different authors are presented. The general review covers investigations from 1838 until the present day, and includes a discussion on observation data, experimental modeling, and theoretical approaches. Section 6.1 is written by Bychkov and Nikitin; authors of the sections 6.2, 6.3 and 6.4 are, respectively, Bychkov, Nikitin and Dijkhuis.

  10. Magnetically operated check valve

    NASA Technical Reports Server (NTRS)

    Morris, Brian G. (Inventor); Bozeman, Richard J., Jr. (Inventor)

    1994-01-01

    A magnetically operated check valve is disclosed. The valve is comprised of a valve body and a movable poppet disposed therein. A magnet attracts the poppet to hold the valve shut until the force of fluid flow through the valve overcomes the magnetic attraction and moves the poppet to an unseated, open position. The poppet and magnet are configured and disposed to trap a magnetically attracted particulate and prevent it from flowing to a valve seating region.

  11. Water ball collision

    NASA Technical Reports Server (NTRS)

    Fujimoto, K.

    1986-01-01

    What happens if a stainless steel ball hits a water ball in the weightless space ot the Universe? In other words, it was the objective of our experiments in the Space to observe the surface tension of liquid by means of making a solid collide with a liquid. Place a small volume of water between 2 glass sheets to make a thin water membrane: the 2 glass sheets cannot be separated unless an enormous force is applied. It is obvious from this phenomenom that the surface tension of water is far greater than presumed. On Earth, however, it is impossible in most cases to observe only the surface tension of liquid, because gravity always acts on the surface tension. Water and stainless steel balls were chosen the liquid and solids for the experiments. Because water is the liquid most familiar to us, its properties are well known. And it is also of great interest to compare its properties on the Earth with those in the weightless space.

  12. Left atrial ball thrombus with acute mesenteric ischemia: anesthetic management and role of transesophageal echocardiography.

    PubMed

    Makhija, Neeti; Malankar, Dhananjay; Singh, Pooja; Goyal, Sameer; Patel, Kartik; Jagia, Priya

    2014-01-01

    A 62 year old female with severe mitral stenosis, large left atrial ball thrombus and acute mesenteric ischemia emergently underwent mitral valve replacement, left atrial clot removal and emergency laparotomy for mesenteric ischemia. Peri-operative management issues, particularly, the anesthetic challenges and the role of transesophageal echocardiography are discussed.

  13. Preliminary characterization of active MEMS valves.

    SciTech Connect

    Barnard, Casey Anderson

    2010-08-01

    Partial characterization of a series of electrostatically actuated active microfluidic valves is to be performed. Tests are performed on a series of 24 valves from two different MEMS sets. Focus is on the physical deformation of the structures under variable pressure loadings, as well as voltage levels. Other issues that inhibit proper performance of the valves are observed, addressed and documented as well. Many microfluidic applications have need for the distribution of gases at finely specified pressures and times. To this end a series of electrostatically actuated active valves have been fabricated. Eight separate silicon die are discussed, each with a series of four active valves present. The devices are designed such that the valve boss is held at a ground, with a voltage applied to lower contacts. Resulting electrostatic forces pull the boss down against a series of stops, intended to create a seal as well as prevent accidental shorting of the device. They have been uniquely packaged atop a stack of material layers, which have inlaid channels for application of fluid flow to the backside of the valve. Electrical contact is supplied from the underlying printed circuit board, attached to external supplies and along traces on the silicon. Pressure is supplied from a reservoir of house compressed air, up to 100 Psig. This is routed through a Norgren R07-200-RGKA pressure regulator, rated to 150 Psig. From there flow passes a manually operated ball valve, and to a flow meter. Two flow meters were utilized; initially an Omega FMA1802 rated at 10 sccm, and followed by a Flocat model for higher flow rates up to 100 sccm. An Omega DPG4000-500 pressure gauge produced pressure measurements. Optical measurements were returned via a WYKO Interferometry probe station. This would allow for determination of physical deformations of the device under a variety of voltage and pressure loads. This knowledge could lead to insight as to the failure mechanisms of the device

  14. Asymptomatic large left-atrial ball thrombus. Secondary to mitral stenosis.

    PubMed Central

    Vitale, M; Agnino, A; Serena, D; Schena, S; Piscitelli, D; Fiore, T; de Luca Tupputi Schinosa, L

    1997-01-01

    We describe the very unusual case of a patient with a large, free-floating left-atrial thrombus secondary to severe mitral stenosis, in whom the peculiar symptoms and complications of a ball thrombus were absent. The patient's only symptom before the episode reported here was mild dyspnea, which was attributed to mitral stenosis. She experienced neither embolism nor syncope. While even her clinical signs did not indicate a left-atrial ball thrombus, both echocardiography and angiography showed a free-floating thrombus. Because of the risk of stroke and acute obstruction of the mitral valve, emergency surgery was performed upon diagnosis of the ball thrombus. The surgery, which consisted of removing the thrombus and replacing the mitral valve with a mechanical prosthesis, was uneventful. A computed tomographic brain scan prior to discharge did not detect any cerebral infarction. Images PMID:9456496

  15. Actuation and system design and evaluation OMS engine shutoff valve, Volume 1. [space shuttles

    NASA Technical Reports Server (NTRS)

    Dunn, V. B.

    1975-01-01

    A technology program was conducted to identify and verify the optimum valve and actuation system concept for the Space Shuttle Orbit Maneuvering System engine. Of major importance to the valve and actuation system selection was the ten-year, 100-mission, 10,000-cycle life requirement, while maintaining high reliability, low leakage, and low weight. Valve and actuation system concepts were comparatively evaluated against past valve failure reports and potential failure modes due to the shuttle mission profile to aid in the selection of the most optimum concept for design, manufacture and verification testing. Two valve concepts were considered during the preliminary design stage; i.e., the moving seat and lifting ball. Two actuation systems were manufactured and tested. Test results demonstrate the viability of a lifting ball concept as well as the applicability of an ac motor actuation system to best meet the requirements of the shuttle mission.

  16. Polyurethane retainers for ball bearings

    NASA Technical Reports Server (NTRS)

    Christy, R. I.

    1973-01-01

    Evaluation of a new ball bearing retainer material is reported. A special composite polyurethane foam ball retainer has been developed that has virtually zero wear, is chemically inert to hydrocarbon lubricants, and stores up to 60 times as much lubricant per unit volume as the most commonly used retainer material, cotton phenolic. This new retainer concept shows promise of years of ball bearing operation without reoiling, based on life testing in high vacuum.

  17. Physics in a Glitter Ball

    ERIC Educational Resources Information Center

    Trikosko, Walter

    2011-01-01

    Maui Toys' Water Bouncer (Fig. 1) is a water-filled ball containing glitter. Buy one and put it on your desk and students can't keep their hands off of it. Pitch the ball in the air giving it a quick spin. When you catch it you will see a sparkling vortex. Twist the ball around different ways and the angular momentum of the fluid keeps the axis of…

  18. PEPC LRU: Ball Support Assembly

    SciTech Connect

    Alger, T

    1999-05-14

    The PEPC LRU upper ball support assembly consists of a ball and a pneumatic air cylinder/conical seat latching mechanism to be attached to the optics support frame,and a ball attached to the PEPC LRU. Both components are designed to allow manual positioning in three axes. Upon insertion of the PEPC LRU into the structure, the upper pneumatic cylinder is actuated to latch the two assemblies together through the conical seat device to grab the lower ball to support the LRU weight. To be conservative, the design load for the assembly is 1500 pounds (the prototype PEPC LRU weight was measured to be near 1380 pounds).

  19. Microfluidic sieve valves

    DOEpatents

    Quake, Stephen R; Marcus, Joshua S; Hansen, Carl L

    2015-01-13

    Sieve valves for use in microfluidic device are provided. The valves are useful for impeding the flow of particles, such as chromatography beads or cells, in a microfluidic channel while allowing liquid solution to pass through the valve. The valves find particular use in making microfluidic chromatography modules.

  20. Remote actuated valve implant

    DOEpatents

    McKnight, Timothy E.; Johnson, Anthony; Moise, Kenneth J.; Ericson, Milton Nance; Baba, Justin S.; Wilgen, John B.; Evans, Boyd Mccutchen

    2016-05-10

    Valve implant systems positionable within a flow passage, the systems having an inlet, an outlet, and a remotely activatable valve between the inlet and outlet, with the valves being operable to provide intermittent occlusion of the flow path. A remote field is applied to provide thermal or magnetic activation of the valves.

  1. Rotary pneumatic valve

    DOEpatents

    Hardee, Harry C.

    1991-01-01

    A rotary pneumatic valve which is thrust balanced and the pneumatic pressure developed produces only radial loads on the valve cylinder producing negligible resistance and thus minimal torque on the bearings of the valve. The valve is multiplexed such that at least two complete switching cycles occur for each revolution of the cylinder spindle.

  2. Liquid rocket valve components

    NASA Technical Reports Server (NTRS)

    1973-01-01

    A monograph on valves for use with liquid rocket propellant engines is presented. The configurations of the various types of valves are described and illustrated. Design criteria and recommended practices for the various valves are explained. Tables of data are included to show the chief features of valve components in use on operational vehicles.

  3. Remote actuated valve implant

    DOEpatents

    McKnight, Timothy E; Johnson, Anthony; Moise, Jr., Kenneth J; Ericson, Milton Nance; Baba, Justin S; Wilgen, John B; Evans, III, Boyd McCutchen

    2014-02-25

    Valve implant systems positionable within a flow passage, the systems having an inlet, an outlet, and a remotely activatable valve between the inlet and outlet, with the valves being operable to provide intermittent occlusion of the flow path. A remote field is applied to provide thermal or magnetic activation of the valves.

  4. Valve-in-valve-in-valve: Treating endocarditis of a transcatheter heart valve.

    PubMed

    Nguyen, Caroline; Cheong, Adrian P; Himbert, Dominique

    2015-10-01

    Transcatheter heart valve endocarditis is a rare, but life threatening complication. We describe the case of a patient who was successfully treated by transcatheter aortic valve-in-valve-in-valve replacement with a favorable 1-year outcome, despite severe early complications.

  5. Dual stage check valve

    NASA Technical Reports Server (NTRS)

    Whitten, D. E. (Inventor)

    1973-01-01

    A dual stage seat valve head arrangement is described which consists of a primary sealing point located between a fixed orifice seat and a valve poppet, and a secondary sealing point between an orifice poppet and a valve poppet. Upstream of the valve orifice is a flexible, convoluted metal diaphragm attached to the orifice poppet. Downstream of the valve orifice, a finger spring exerts a force against the valve poppet, tending to keep the valve in a closed position. The series arrangement of a double seat and poppet is able to tolerate small particle contamination while minimizing chatter by controlling throttling or metering across the secondary seat, thus preserving the primary sealing surface.

  6. Valve-in-Valve Replacement Using a Sutureless Aortic Valve

    PubMed Central

    Dohmen, Pascal M.; Lehmkuhl, Lukas; Borger, Michael A.; Misfeld, Martin; Mohr, Friedrich W.

    2016-01-01

    Patient: Female, 61 Final Diagnosis: Tissue degeneration Symptoms: Dyspnea Medication: — Clinical Procedure: Redo valve replacement Specialty: Surgery Objective: Rare disease Background: We present a unique case of a 61-year-old female patient with homograft deterioration after redo surgery for prosthetic valve endocarditis with root abscess. Case Report: The first operation was performed for type A dissection with root, arch, and elephant trunk replacement of the thoracic aorta. The present re-redo surgery was performed as valve-in-valve with a sutureless aortic biopros-thesis. The postoperative course was uneventful and the patient was discharged on day 6. Conclusions: The current case report demonstrates that sutureless bioprostheses are an attractive option for surgical valve-in-valve procedures, which can reduce morbidity and mortality. PMID:27694795

  7. The "Policy Cycle": A Ball by Ball Account.

    ERIC Educational Resources Information Center

    Hatcher, Richard; Troyna, Barry

    1994-01-01

    Concerned with Stephen Ball's theoretical and empirical contribution to contemporary "education policy sociology," this article examines the efficacy of his theoretical eclecticism, highlighting incompatibilities in his interpretation and application of certain social and political theorists. Ball's representation of the policy cycle, as applied…

  8. Scissor thrust valve actuator

    DOEpatents

    DeWall, Kevin G.; Watkins, John C; Nitzel, Michael E.

    2006-08-29

    Apparatus for actuating a valve includes a support frame and at least one valve driving linkage arm, one end of which is rotatably connected to a valve stem of the valve and the other end of which is rotatably connected to a screw block. A motor connected to the frame is operatively connected to a motor driven shaft which is in threaded screw driving relationship with the screw block. The motor rotates the motor driven shaft which drives translational movement of the screw block which drives rotatable movement of the valve driving linkage arm which drives translational movement of the valve stem. The valve actuator may further include a sensory control element disposed in operative relationship with the valve stem, the sensory control element being adapted to provide control over the position of the valve stem by at least sensing the travel and/or position of the valve stem.

  9. Holy Balls!: Part Deux

    NASA Astrophysics Data System (ADS)

    Belden, Jesse; Jandron, Michael; Truscott, Tadd

    2012-11-01

    A Waboba® (WAter BOuncing BAll) demonstrates remarkable water skipping behavior, even at relatively large impact angles. The highly compliant nature of these elastic spheres results in significant deformation into a disk-like shape upon impact. The increased wetted area and force coefficient generates a large hydrodynamic force that more readily lifts the ball off the water surface. However, elasticity introduces some surprising phenomena, such as material waves that propagate on the sphere and interact with the water cavity. Depending upon impact conditions, material waves may propagate in various directions combining to create multiple modes of deformation and complicated fluid-structure interactions. Furthermore, the timescales of deformation and wave propagation depend on the material properties and impact conditions. In this talk, we will discuss skipping regimes in terms of impact parameters and material properties and relate failed skipping behavior to the structure-fluid interaction caused by deformation. The critical timescales for deformation, wave propagation and collision will be related to the relevant physical parameters of the problem.

  10. Atmospheric Ball Plasma Interactions

    NASA Astrophysics Data System (ADS)

    Wurden, C. J. V.; Wurden, G. A.

    2008-11-01

    Free-floating atmospheric pressure copper hydroxyl ball plasmas have been studied in air and helium atmospheres, using still and high speed photography (up to 20,000 fps), collimated photodiodes, and spectroscopy. A fine boundary layer between the greenish Cu-OH cloud, and the air, is orange in color. However, when the discharge is initiated into a helium atmosphere, the boundary layer is no longer visible, suggesting that the visible boundary was caused by interactions with oxygen. We have studied scaling of the 10-cm diameter ball plasmas with both the size of the water bucket, and the applied discharge voltage, over the range of 500-5000 volts. When looking at the initial spider-leg breakdown above the water surface, the ratio of H-alpha to H-beta lines suggests a temperature of ˜0.3 eV. This is also consistent with the presence of molecular lines of OH, and perhaps CuOH2 in the rising cloud. The cloud is affected by, but can penetrate through an aluminum window screen mesh.

  11. Valve for fluid control

    SciTech Connect

    Oborny, Michael C.; Paul, Phillip H.; Hencken, Kenneth R.; Frye-Mason, Gregory C.; Manginell, Ronald P.

    2001-01-01

    A valve for controlling fluid flows. This valve, which includes both an actuation device and a valve body provides: the ability to incorporate both the actuation device and valve into a unitary structure that can be placed onto a microchip, the ability to generate higher actuation pressures and thus control higher fluid pressures than conventional microvalves, and a device that draws only microwatts of power. An electrokinetic pump that converts electric potential to hydraulic force is used to operate, or actuate, the valve.

  12. Means for positively seating a piezoceramic element in a piezoelectric valve during inlet gas injection

    DOEpatents

    Wright, Kenneth E.

    1994-01-01

    A piezoelectric valve in a gas delivery system includes a piezoceramic element bonded to a valve seal and disposed over a valve seat, and retained in position by an O-ring and a retainer; an insulating ball normally biased by a preload spring against the piezoceramic element; an inlet gas port positioned such that upon admission of inlet gas into the valve, the piezoceramic element is positively seated. The inlet gas port is located only on the side of the piezoceramic element opposite the seal.

  13. Means for positively seating a piezoceramic element in a piezoelectric valve during inlet gas injection

    DOEpatents

    Wright, K.E.

    1994-08-23

    A piezoelectric valve in a gas delivery system includes a piezoceramic element bonded to a valve seal and disposed over a valve seat, and retained in position by an O-ring and a retainer; an insulating ball normally biased by a preload spring against the piezoceramic element; an inlet gas port positioned such that upon admission of inlet gas into the valve, the piezoceramic element is positively seated. The inlet gas port is located only on the side of the piezoceramic element opposite the seal. 3 figs.

  14. A means for positively seating a piezoceramic element in a piezoelectric valve during inlet gas injection

    SciTech Connect

    Wright, K.E.

    1993-12-31

    This invention is comprised of a piezoelectric valve in a gas delivery system which includes a piezoceramic element bonded to a valve seal and disposed over a valve seat, and retained in position by an O-ring and a retainer; and insulating ball normally biased by a preload spring against the piezoceramic element; and inlet gas port positioned such that upon admission of inlet gas into the valve. The piezoceramic element is positively seated. The inelt gas port is located only on the side of the piezoceramic element opposite the seal.

  15. Behaviour of a Bouncing Ball

    ERIC Educational Resources Information Center

    Cross, Rod

    2015-01-01

    The bounce of a ball is a seemingly innocuous event that can be used to illustrate many aspects of elementary and even advanced mechanics. Both normal and oblique bounces on a rigid surface are considered in this article, emphasizing qualitative features of the bounce process. If the ball bounces at an oblique angle then it can slide throughout…

  16. High-Performance Ball Bearing

    NASA Technical Reports Server (NTRS)

    Bursey, Roger W., Jr.; Haluck, David A.; Olinger, John B.; Owen, Samuel S.; Poole, William E.

    1995-01-01

    High-performance bearing features strong, lightweight, self-lubricating cage with self-lubricating liners in ball apertures. Designed to operate at high speed (tens of thousands of revolutions per minute) in cryogenic environment like liquid-oxygen or liquid-hydrogen turbopump. Includes inner race, outer race, and cage keeping bearing balls equally spaced.

  17. Structure of laboratory ball lightning.

    PubMed

    Ito, Tsuyohito; Tamura, Tomoya; Cappelli, Mark A; Hamaguchi, Satoshi

    2009-12-01

    Trajectories of self-sustained laboratory ball lightning, generated by arc discharges with silicon, are investigated for understanding the possibility of buoyant flight. Extremely low apparent densities are found, nearly approaching that of standard air. The freely buoyant balls are observed to survive for about 0.1 s, with significantly buoyant balls surviving for several seconds. These ball lightning objects are found to have a density and size that can easily allow them to be carried by a gentle breeze of a few meters per second. The results are interpreted by a model that is an extension of that first proposed by Abrahamson and Dinniss [J. Abrahamson and J. Dinniss, Nature (London) 403, 519 (2000)]. The buoyant behavior of ball lightning seen in our experiments is believed to arise as a result of the formation of a nanoparticle oxide network growing from a molten silicon core.

  18. Structure of laboratory ball lightning

    NASA Astrophysics Data System (ADS)

    Ito, Tsuyohito; Tamura, Tomoya; Cappelli, Mark A.; Hamaguchi, Satoshi

    2009-12-01

    Trajectories of self-sustained laboratory ball lightning, generated by arc discharges with silicon, are investigated for understanding the possibility of buoyant flight. Extremely low apparent densities are found, nearly approaching that of standard air. The freely buoyant balls are observed to survive for about 0.1 s, with significantly buoyant balls surviving for several seconds. These ball lightning objects are found to have a density and size that can easily allow them to be carried by a gentle breeze of a few meters per second. The results are interpreted by a model that is an extension of that first proposed by Abrahamson and Dinniss [J. Abrahamson and J. Dinniss, Nature (London) 403, 519 (2000)]. The buoyant behavior of ball lightning seen in our experiments is believed to arise as a result of the formation of a nanoparticle oxide network growing from a molten silicon core.

  19. Reflections on a Bouncing Ball

    NASA Astrophysics Data System (ADS)

    Rohr, Jim; Lopez, Veronica; Rohr, Tyler

    2014-12-01

    While observing the bounce heights of various kinds of sports balls dropped from different heights onto a variety of surfaces, we thought of the following question: Could measurements of drop and bounce heights of balls of different diameters, but of the same material, falling from different heights, but on the same surface, be expressed by a simple mathematical formula? Our objective was to provide a simple classroom ball-drop experiment that produced robust and interesting data sets from which students could address this question. With a suitable choice of variables, all the ball drop data could be collapsed to a single curve, so that given the mass and drop height of the ball, the bounce height could be reasonably estimated (±10% of measured values).

  20. Structure of laboratory ball lightning.

    PubMed

    Ito, Tsuyohito; Tamura, Tomoya; Cappelli, Mark A; Hamaguchi, Satoshi

    2009-12-01

    Trajectories of self-sustained laboratory ball lightning, generated by arc discharges with silicon, are investigated for understanding the possibility of buoyant flight. Extremely low apparent densities are found, nearly approaching that of standard air. The freely buoyant balls are observed to survive for about 0.1 s, with significantly buoyant balls surviving for several seconds. These ball lightning objects are found to have a density and size that can easily allow them to be carried by a gentle breeze of a few meters per second. The results are interpreted by a model that is an extension of that first proposed by Abrahamson and Dinniss [J. Abrahamson and J. Dinniss, Nature (London) 403, 519 (2000)]. The buoyant behavior of ball lightning seen in our experiments is believed to arise as a result of the formation of a nanoparticle oxide network growing from a molten silicon core. PMID:20365306

  1. The ISOLDE Silicon Ball

    SciTech Connect

    Fraile, L.M.

    2003-09-16

    The investigation of weakly bound nuclei close to the particle driplines makes necessary the development of new spectroscopy devices with the capability of detecting charged particles and precisely determining their energy, angular distribution and nature. With this aim the ISOLDE Silicon Ball is under construction. It is a charged particle spectroscopy device with the requirements of high geometrical efficiency and broad energy range coverage, designed for the investigation of the exotic nuclei produced at ISOLDE and at other similar facilities. In order to allow for particle identification the simultaneous use of the Time of Flight (TOF) and Pulse Shape Discrimination (PSD) techniques is intended. Recoil tagging capabilities, suitable for transfer reactions to be performed at REX-ISOLDE, should be foreseen for a future development. The design and realization of the first prototype, together with the first tests are reported.

  2. Cracked cue ball

    NASA Astrophysics Data System (ADS)

    Carlowicz, Michael

    The latest images sent by the Galileo spacecraft reveal that the surface of Jupiter's moon Europa may have contained a layer of “warm ice” or even liquid water. In fact, planetologists are wondering if perhaps it still does.Photos taken earlier this summer show Europa to have a crust of smooth white and brown-tinted ice scarred by long, jagged cracks; some scientists have said the moon looks like a cracked cue ball. “The scale of fracture patterns—extending a distance equivalent to the width of the western United States—dwarf the San Andreas fault in length and width,” said Ronald Greeley, a geologist from Arizona State University and a member of the Galileo imaging team. The cracks are believed to have been caused by the stress of tidal forces created by Jupiter's gravity. Warmth generated by tidal heating also may have been sufficient to soften or liquefy some of the ice.

  3. A new valve retractor for mitral valve procedures.

    PubMed

    Lucchese, F A; Kalil, R; Prates, P R; Nesralla, I A; Jatene, A D

    1980-02-01

    Optimal exposure greatly facilitates reconstructive mitral valve procedures. We describe an effective method for exposing this valve using a specially designed mitral valve retractor. This technique proved useful in 321 patients who underwent operation on the mitral valve.

  4. Fast acting check valve

    NASA Technical Reports Server (NTRS)

    Perkins, Gerald S. (Inventor)

    1979-01-01

    A check valve which closes more rapidly to prevent wearing of the valve seat and of the valve member that seals thereagainst, including a solenoid or other actuator that aids the normal spring to quickly close the valve at approximately the time when downpath fluid flow would stop, the actuator then being deenergized. The control circuit that operates the actuator can include a pair of pressure sensors sensing pressure both upstream and downstream from the valve seat. Where the valve is utilized to control flow to or from a piston pump, energization of the actuator can be controlled by sensing when the pump piston reaches its extreme of travel.

  5. Quickly Removable Valve

    NASA Technical Reports Server (NTRS)

    Robbins, John S.

    1988-01-01

    Unit removed with minimal disturbance. Valve inlet and outlet ports adjacent to each other on same side of valve body. Ports inserted into special manifold on fluid line. Valve body attached to manifold by four bolts or, alternatively, by toggle clamps. Electromechanical actuator moves in direction parallel to fluid line to open and close valve. When necessary to clean valve, removed simply by opening bolts or toggle clamps. No need to move or separate ports of fluid line. Valve useful where disturbance of fluid line detrimental or where fast maintenance essential - in oil and chemical industries, automotive vehicles, aircraft, and powerplants.

  6. Unsolved Mystery of Ball Lightning

    NASA Astrophysics Data System (ADS)

    Bychkov, V. L.

    Ball lightning is an unusual phenomenon always drawing attention of people. There are still questions about its origination, features, interaction with environment, and phenomena related to it. On a way of studying this phenomenon, there are a lot of difficulties, the basic of them is insufficiency of authentic, scientific data. The chapter sets as the purpose to interest the reader in the problem, to describe conditions of ball lightning occurrence, theories, and its hypotheses explanation, to include readers in a circle of experimental searches in creation of a ball lightning and its analogues, and to describe fascination of a problem and difficulty of its solution.

  7. Pump isolation valve

    DOEpatents

    Kinney, Calvin L.; Wetherill, Todd M.

    1983-08-02

    The pump isolation valve provides a means by which the pump may be selectively isolated from the remainder of the coolant system while being compatible with the internal hydraulic arrangement of the pump during normal operation of the pump. The valve comprises a valve cylinder disposed around the pump and adjacent to the last pump diffuser with a turning vane attached to the lower end of the valve cylinder in a manner so as to hydraulically match with the discharge diffuser. The valve cylinder is connected to a drive means for sliding the valve cylinder relative to the diffuser support cylinder so as to block flow in either direction through the discharge diffuser when the valve is in the closed position and to aid in the flow of the coolant from the discharge diffuser by means of the turning vane when the valve is in the open position.

  8. Mitral Valve Disease

    MedlinePlus

    ... disease occurs when the mitral valve doesn’t work properly. Types of Mitral Valve Disease Types of ... until you are able to go back to work, depending on your job. Everyday activities such as ...

  9. Mitral valve surgery - open

    MedlinePlus

    ... place. There are two types of mitral valves: Mechanical, made of man-made (synthetic) materials, such as ... Mechanical heart valves do not fail often. They last from 12 to 20 years. However, blood clots ...

  10. Aortic valve surgery - open

    MedlinePlus

    ... There are two main types of new valves: Mechanical, made of man-made materials, such as titanium ... Mechanical heart valves do not fail often. However, blood clots can develop on them. If a blood ...

  11. Valve Health Monitor (VHM)

    NASA Technical Reports Server (NTRS)

    Perotti, Jose M.; Delgado, H. (Technical Monitor)

    2002-01-01

    This presentation reports on progress being made on developing a Valve Health Monitor (VHM) Smart Current Signature Sensor. Topics cover include: design needs, target valves, current signatures, VHM design approach and VHM status/conclusions.

  12. The coefficient of restitution for collisions of happy balls, unhappy balls, and tennis balls

    NASA Astrophysics Data System (ADS)

    Cross, Rod

    2000-11-01

    A perfectly happy ball is one that bounces to its original height when dropped on a massive, rigid surface. A completely unhappy ball does not bounce at all. In the former case, the coefficient of restitution (COR) is unity. In the latter case, the COR is zero. It is shown that when an unhappy ball collides with a happy ball, the COR increases from zero to unity as the stiffness of the happy ball decreases from infinity to zero. The COR is independent of the mass of each ball. The implication of reducing the COR of a tennis ball, as a possible means of slowing the serve in tennis, is also considered. It is shown that (a) the COR for a collision with a racket varies with the impact point and is a maximum at the vibration node near the center of the strings, and (b) the serve speed is reduced by only about 20% if the COR for a bounce on the court is reduced to zero.

  13. High-pressure cryogenic valves for the Vulcain rocket motor

    NASA Astrophysics Data System (ADS)

    Garceau, P.; Meyer, F.

    The high-pressure valve developed to control the flow of liquid oxygen or hydrogen into the gas generator of the ESA Vulcain rocket motor is described. The spherical ball-seal design employed provides high reliability over a service lifetime of 5000 on-off actuations at temperatures 20-350 K and pressures up to 200 bar. Leakage is limited to a few cu cm/sec of hydrogen at 20 K. The steps in the development process, from the definition of the valve specifications to the fabrication and testing phase are reviewed, and the final design is shown in drawings, diagrams, and photographs.

  14. Aerodynamic Shutoff Valve

    NASA Technical Reports Server (NTRS)

    Horstman, Raymond H.

    1992-01-01

    Aerodynamic flow achieved by adding fixed fairings to butterfly valve. When valve fully open, fairings align with butterfly and reduce wake. Butterfly free to turn, so valve can be closed, while fairings remain fixed. Design reduces turbulence in flow of air in internal suction system. Valve aids in development of improved porous-surface boundary-layer control system to reduce aerodynamic drag. Applications primarily aerospace. System adapted to boundary-layer control on high-speed land vehicles.

  15. Overflow control valve

    DOEpatents

    Hundal, Rolv; Kessinger, Boyd A.; Parlak, Edward A.

    1984-07-24

    An overflow control valve for use in a liquid sodium coolant pump tank which valve can be extended to create a seal with the pump tank wall or retracted to break the seal thereby accommodating valve removal. An actuating shaft which controls valve disc position also has cams which bear on roller surfaces to force retraction of a sliding cylinder against spring tension to retract the cylinder from sealing contact with the pump tank.

  16. Enhancing the Bounce of a Ball

    ERIC Educational Resources Information Center

    Cross, Rod

    2010-01-01

    In sports such as baseball, softball, golf, and tennis, a common objective is to hit the ball as fast or as far as possible. Another common objective is to hit the ball so that it spins as fast as possible, since the trajectory of the ball through the air is strongly affected by ball spin. In an attempt to enhance both the coefficient of…

  17. Pump, and earth-testable spacecraft capillary heat transport loop using augmentation pump and check valves

    NASA Technical Reports Server (NTRS)

    Baker, David (Inventor)

    1998-01-01

    A spacecraft includes heat-generating payload equipment, and a heat transport system with a cold plate thermally coupled to the equipment and a capillary-wick evaporator, for evaporating coolant liquid to cool the equipment. The coolant vapor is coupled to a condenser and in a loop back to the evaporator. A heated coolant reservoir is coupled to the loop for pressure control. If the wick is not wetted, heat transfer will not begin or continue. A pair of check valves are coupled in the loop, and the heater is cycled for augmentation pumping of coolant to and from the reservoir. This augmentation pumping, in conjunction with the check valves, wets the wick. The wick liquid storage capacity allows the augmentation pump to provide continuous pulsed liquid flow to assure continuous vapor transport and a continuously operating heat transport system. The check valves are of the ball type to assure maximum reliability. However, any type of check valve can be used, including designs which are preloaded in the closed position. The check valve may use any ball or poppet material which resists corrosion. For optimum performance during testing on Earth, the ball or poppet would have neutral buoyancy or be configured in a closed position when the heat transport system is not operating. The ball may be porous to allow passage of coolant vapor.

  18. Behaviour of a bouncing ball

    NASA Astrophysics Data System (ADS)

    Cross, Rod

    2015-05-01

    The bounce of a ball is a seemingly innocuous event that can be used to illustrate many aspects of elementary and even advanced mechanics. Both normal and oblique bounces on a rigid surface are considered in this article, emphasizing qualitative features of the bounce process. If the ball bounces at an oblique angle then it can slide throughout the bounce, or just at the start of the bounce, and may even slide backwards at the end of the bounce. A ball can also grip the surface after a short sliding phase, or it can grip right from the start. When the ball grips, static friction rather than sliding friction determines the rebound speed, spin and angle.

  19. Microblower assisted barometric valve

    DOEpatents

    Rossabi, Joseph; Hyde, Warren K.; Riha, Brian D.; Jackson, Dennis G.; Sappington, Frank

    2005-12-06

    A gas exchange apparatus is provided which provides for both passive fluid flow and blower associated fluid flow through a barometric valve. A battery powered blower is provided which allows for operation of the barometric valve during times when the barometric valve would otherwise be closed, and provides for enhanced volume of gas exchange.

  20. Heart Valve Diseases

    MedlinePlus

    Your heart has four valves. Normally, these valves open to let blood flow through or out of your heart, and then shut to keep it from flowing ... close tightly. It's one of the most common heart valve conditions. Sometimes it causes regurgitation. Stenosis - when ...

  1. Liquid rocket valve assemblies

    NASA Technical Reports Server (NTRS)

    1973-01-01

    The design and operating characteristics of valve assemblies used in liquid propellant rocket engines are discussed. The subjects considered are as follows: (1) valve selection parameters, (2) major design aspects, (3) design integration of valve subassemblies, and (4) assembly of components and functional tests. Information is provided on engine, stage, and spacecraft checkout procedures.

  2. Dump valve assembly

    DOEpatents

    Owen, T.J.

    1984-01-01

    A dump valve assembly comprising a body having a bore defined by a tapered wall and a truncated spherical valve member adapted to seat along a spherical surface portion thereof against said tapered wall. Means are provided for pivoting said valve member between a closed position engagable with said tapered wall and an open position disengaged therefrom.

  3. Lock For Valve Stem

    NASA Technical Reports Server (NTRS)

    Burley, Richard K.; Guirguis, Kamal S.

    1991-01-01

    Simple, cheap device locks valve stem so its setting cannot be changed by unauthorized people. Device covers valve stem; cover locked in place with standard padlock. Valve lock made of PVC pipe and packing band. Shears, drill or punch, and forming rod only tools needed.

  4. In vitro flow dynamics of four prosthetic aortic valves: a comparative analysis.

    PubMed

    Hanle, D D; Harrison, E C; Yoganathan, A P; Allen, D T; Corcoran, W H

    1989-01-01

    The velocity fields downstream of four prosthetic heart valves were mapped in vitro over the entire cross-section of a model aortic root using laser Doppler anemometry. THe Björk-Shiley 60 degrees convexo-concave tilting disc valve, the Smeloff-Cutter caged ball valve, the St. Jude Medical bileaflet valve, and the Ionescu-Shiley standard bioprosthesis were examined under both steady and pulsatile flows. Velocity profiles under steady flow conditions were a good approximation for pulsatile profiles only during midsystole. The pulsatile flow characteristics of the four valves showed variation in large scale flow structures. Comparison of the valves according to pressure drop, shear stress and maximum velocities are also provided. PMID:2808443

  5. History of ball bearings

    NASA Technical Reports Server (NTRS)

    Dowson, D.; Hamrock, B. J.

    1981-01-01

    The familiar precision rolling-element bearings of the twentieth century are products of exacting technology and sophisticated science. Their very effectiveness and basic simplicity of form may discourage further interest in their history and development. Yet the full story covers a large portion of recorded history and surprising evidence of an early recognition of the advantages of rolling motion over sliding action and progress toward the development of rolling-element bearings. The development of rolling-element bearings is followed from the earliest civilizations to the end of the eighteenth century. The influence of general technological developments, particularly those concerned with the movement of large building blocks, road transportation, instruments, water-raising equipment, and windmills are discussed, together with the emergence of studies of the nature of rolling friction and the impact of economic factors. By 1800 the essential features of ball and rolling-element bearings had emerged and it only remained for precision manufacture and mass production to confirm the value of these fascinating machine elements.

  6. MODIFIED BALL AND SOCKET COUPLING

    DOEpatents

    Kalen, D.D.

    1961-05-23

    A ball and socket coupling arrangement is described in which the male and female members may be engaged or disengaged without visual aid. The female member has an internal spherical seat through which slots are provided to accommodate appropriately arranged and shaped ribs in the ball member. After engagement of the members, one or both are rotated to lock them together to prevent accidental disengagement. (AEC)

  7. Modified Ball and Socket Coupling

    DOEpatents

    Conley, Jr, W. R.; Pitman, R. W.

    1961-05-23

    A ball and socket coupling arrangement is given in which the male and female members may be engaged or disengaged without visual aid. The female member has an internal spherical seat through which slots are provided to accommodate appropriately arranged and shaped ribs in the male ball member. After engagement of the members, one or both are rotated to lock them together to prevent accidental disengagement.

  8. Ball-joint grounding ring

    NASA Technical Reports Server (NTRS)

    Aperlo, P. J. A.; Buck, P. A.; Weldon, V. A.

    1981-01-01

    In ball and socket joint where electrical insulator such as polytetrafluoroethylene is used as line to minimize friction, good electrical contact across joint may be needed for lightning protection or to prevent static-charge build-up. Electrical contact is maintained by ring of spring-loaded fingers mounted in socket. It may be useful in industry for cranes, trailers, and other applications requiring ball and socket joint.

  9. [History, present and future of biomaterials used for artificial heart valves].

    PubMed

    Kostrzewa, Benita; Rybak, Zbigniew

    2013-01-01

    Artificial heart valves can be classified into mechanical and biological. We have three types of mechanical heart valves: caged ball, tilting disc and bileaflet. Mechanical heart valves are made from various materials. They may be produced from metals, ceramics and polymers, e.g.: stainless steel, titanium, silicone, pyrolytic carbon. Biological valves are made from synthetic components (e.g.: PTFE, Dacron) and materials of biological origin (e.g.: cow pericardium, pig heart valve). We have also identified transcatheter aortic valve implantation (TAVI). TAVI may be produced from metals, ceramics and polymers (e.g.: stainless steel, titanium, Dacron) and biological material (e.g.: pig heart valve). This paper describes advantages and disadvantages of different types of artificial heart valves. The lifespan of mechanical valves is 20-30 years and they can be used for patients of any age. Mechanical valves have also disadvantages--anticoagulants are required to prevent thrombosis. Biological valves are made from natural materials, so they do not require prolonged anticoagulation. Their lifetime is 10-15 years, so they are offered to patients over 40 years. Another problem is the occurrence of calcification.

  10. Minimally Invasive Valve Surgery

    PubMed Central

    Pope, Nicolas H.; Ailawadi, Gorav

    2014-01-01

    Cardiac valve surgery is life saving for many patients. The advent of minimally invasive surgical techniques has historically allowed for improvement in both post-operative convalescence and important clinical outcomes. The development of minimally invasive cardiac valve repair and replacement surgery over the past decade is poised to revolutionize the care of cardiac valve patients. Here, we present a review of the history and current trends in minimally invasive aortic and mitral valve repair and replacement, including the development of sutureless bioprosthetic valves. PMID:24797148

  11. Main Oxidizer Valve Design

    NASA Technical Reports Server (NTRS)

    Addona, Brad; Eddleman, David

    2015-01-01

    A developmental Main Oxidizer Valve (MOV) was designed by NASA-MSFC using additive manufacturing processes. The MOV is a pneumatically actuated poppet valve to control the flow of liquid oxygen to an engine's injector. A compression spring is used to return the valve to the closed state when pneumatic pressure is removed from the valve. The valve internal parts are cylindrical in shape, which lends itself to traditional lathe and milling operations. However, the valve body represents a complicated shape and contains the majority of the mass of the valve. Additive manufacturing techniques were used to produce a part that optimized mass and allowed for design features not practical with traditional machining processes.

  12. Enhancing the Bounce of a Ball

    NASA Astrophysics Data System (ADS)

    Cross, Rod

    2010-10-01

    In sports such as baseball, softball, golf, and tennis, a common objective is to hit the ball as fast or as far as possible. Another common objective is to hit the ball so that it spins as fast as possible, since the trajectory of the ball through the air is strongly affected by ball spin. In an attempt to enhance both the coefficient of restitution (COR) and the spin of a golf ball, I conducted several experiments to see what would happen when a 45-g, 42.8-mm diameter golf ball bounced on: (a) a 58-mm diameter, 103-g Super Ball®; (b) an 8-mm thick, 56-mm diameter circular disk of Super Ball material cut from a large Super Ball and glued to a 3.4-kg lead brick; and (c) a 3-mm thick sheet of rubber glued to a 3.4-kg lead brick. (See Fig. 1.)

  13. Valve selection in aortic valve endocarditis

    PubMed Central

    Zubrytska, Yana

    2016-01-01

    Aortic prosthetic valve endocarditis (PVE) is a potentially life-threatening disease. Mortality and incidence of infective endocarditis have been reduced in the past 30 years. Medical treatment of aortic PVE may be successful in patients who have a prompt response after antibiotic treatment and who do not have prosthetic dysfunction. In advanced stages, antibiotic therapy alone is insufficient to control the disease, and surgical intervention is necessary. Surgical treatment may be lifesaving, but it is still associated with considerable morbidity and mortality. The aim of surgery is to perform a radical excision of all infected and necrotic tissue, reconstruction of the left ventricle outflow tract, and replacement of the aortic valve. There is no unanimous consensus on which is the optimal prosthesis to implant in this context, and several surgical techniques have been suggested. We aim to analyze the efficacy of the surgical treatment and discuss the issue of valve selection in patients with aortic valve endocarditis. PMID:27785132

  14. CAM operated fuel valve

    SciTech Connect

    Kelly, S.T.; Katchka, J.R.

    1991-09-03

    This patent describes improvement in a fuel control valve construction comprising a housing means having an inlet means adapted to be interconnected to a fuel source and a main outlet means adapted to be interconnected to a main burner means, the housing means having a main valve seat for interconnecting the inlet means with the main outlet means, the housing means having a movable main valve member for opening and closing the main valve seat, the housing means having a movable lever operatively associated with the main valve member and having a manually operable actuator means for controlling the operating positions of the lever, the lever having an intermediate cam follower portion and opposed ends disposed on each side of the cam follower portion with one end of the opposed ends being pivotally mounted to the housing means and with the other end of the opposed ends for operating the main valve member, the housing means having biasing means operatively interconnected to the lever to tend to pivot the lever in one direction that opens the main valve member away from its the main valve seat. The improvement comprises; the housing means has a thermostatically controlled means that is operatively associated with the lever and is adapted to engage and hold the lever in a position wherein the main valve member is in a closed condition against its the main valve seat when the thermostatically controlled means is in one operating condition thereof and the actuator means is in the on condition thereof.

  15. MIPP Plastic Ball electronics upgrade

    SciTech Connect

    Baldin, Boris; /Fermilab

    2009-01-01

    An upgrade electronics design for Plastic Ball detector is described. The Plastic Ball detector was a part of several experiments in the past and its back portion (proposed to be used in MIPP) consists of 340 photomultipliers equipped with a sandwich scintillator. The scintillator sandwich has fast and slow signal component with decay times 10 ns and 1 {micro}s respectively. The upgraded MIPP experiment will collect up to 12,000 events during each 4 second spill and read them out in {approx}50 seconds between spills. The MIPP data acquisition system will employ deadtime-less concept successfully implemented in Muon Electronics of Dzero experiment at Fermilab. An 8-channel prototype design of the Plastic Ball Front End (PBFE) implementing these requirements is discussed. Details of the schematic design, simulation and prototype test results are discussed.

  16. Dynamics of a bouncing ball

    NASA Astrophysics Data System (ADS)

    Chastaing, J.-Y.; Bertin, E.; Géminard, J.-C.

    2015-06-01

    We describe an experiment dedicated to the study of the trajectories of a ball bouncing on a vibrating plate. Using an experimental device of our own design, it is possible to impose arbitrary trajectories on the plate and we show that the entire trajectory of the ball can be reconstructed solely from measurement of the times the ball hits the plate. In this paper, we make use of our apparatus to introduce the notion of dissipative collisions and to propose three different ways to measure the associated restitution coefficient. We then report on correlations in the chaotic regime and theoretically discuss the complex patterns that are exhibited in the case of a sinusoidal vibration. Lastly, we show that the use of an aperiodic driving vibration makes it possible to minimize part of these correlations.

  17. Imaging characteristics of ball lens

    NASA Astrophysics Data System (ADS)

    Li, Qinghui; Shao, Xiaopeng

    2014-05-01

    In most digital imaging applications, high-resolution imaging or videos are usually desired for later processing and analysis. The desire for high-resolution stems from two principal application areas: improvement of pictorial information for human interpretation, and helping representation for automatic machine preception. While the image sensors limit the spatial resolution of the image, the image details are also limited by the optical system, due to diffraction, and aberration1. Monocentric lens are an attractive option for gigapixel camera because the symmetrical design focuses light identically coming from any direction. Marks and Brady proposed a monocentric lens design imaging 40 gigapixels with an f-number of 2.5 and resolving 2 arcsec over a 120 degrees field of view2. Recently, Cossairt, Miau, and Nayer proposed a proof-of-concept gigapixel computational camera consisting of a large ball lens shared by several small planar sensors coupled with a deblurring step3. The design consists of a ball element resulting in a lens that is both inexpensive to produce and easy to align. Because the resolution of spherical lens is fundamentally limited by geometric aberrations, the imaging characteristics of the ball lens is expressed by the geometrical aberrations, in which the general equations for the primary aberration of the ball lens are given. The effect of shifting the stop position on the aberrations of a ball lens is discussed. The variation of the axial chromatic aberration with the Abbe V-number when the refraction index takes different values is analyzed. The variation of the third-order spherical aberration ,the fifth-order spherical aberration and the spherical aberration obtained directly from ray tracing with the f-number is discussed. The other imaging evaluation merits, such as the spot diagram, the modulation transfer function(MTF) and the encircled energy are also described. Most of the analysis of the ball lens is carried out using OSLO optics

  18. Intelligent Flow Control Valve

    NASA Technical Reports Server (NTRS)

    Kelley, Anthony R (Inventor)

    2015-01-01

    The present invention is an intelligent flow control valve which may be inserted into the flow coming out of a pipe and activated to provide a method to stop, measure, and meter flow coming from the open or possibly broken pipe. The intelligent flow control valve may be used to stop the flow while repairs are made. Once repairs have been made, the valve may be removed or used as a control valve to meter the amount of flow from inside the pipe. With the addition of instrumentation, the valve may also be used as a variable area flow meter and flow controller programmed based upon flowing conditions. With robotic additions, the valve may be configured to crawl into a desired pipe location, anchor itself, and activate flow control or metering remotely.

  19. Automatic rotary valve actuator

    SciTech Connect

    Cook, W.E.

    1985-03-28

    This report describes the design, construction, and operation of a microcomputer-controlled valve actuator for operating test valves requiring rotary motion of the valve stem. An AIM 65 microcomputer, using a FORTH language program, controls an air motor and air clutch mounted within an oven to accomplish testing at elevated temperatures. The valve actuator closes the test valve until a preset torque is reached and then opens the valve to its initial starting point. The number of cycles and extremes of rotation are tallied and printed as the test progresses. Provisions are made to accept remote signals to stop the test and to indicate to a remote device when the test has been stopped.

  20. JenaValve.

    PubMed

    Treede, Hendrik; Rastan, Ardawan; Ferrari, Markus; Ensminger, Stephan; Figulla, Hans-Reiner; Mohr, Friedrich-Wilhelm

    2012-09-01

    The JenaValve is a next-generation TAVI device which consists of a well-proven porcine root valve mounted on a low-profile nitinol stent. Feeler guided positioning and clip fixation on the diseased leaflets allow for anatomically correct implantation of the device without rapid pacing. Safety and efficacy of transapical aortic valve implantation using the JenaValve were evaluated in a multicentre prospective study that showed good short and midterm results. The valve was CE-mark released in Europe in September 2011. A post-market registry ensures on-going and prospective data collection in "real-world" patients. The transfemoral JenaValve delivery system will be evaluated in a first-in-man study in the near future. PMID:22995119

  1. Ball lightning risk to aircraft

    NASA Astrophysics Data System (ADS)

    Doe, R.; Keul, A.

    2009-04-01

    Lightning is a rare but regular phenomenon for air traffic. Aircraft are designed to withstand lightning strikes. Research on lightning and aircraft can be called detailed and effective. In the last 57 years, 18 reported lightning aviation disasters with a fatality figure of at least 714 persons occurred. For comparison, the last JACDEC ten-year average fatality figure was 857. The majority encountered lightning in the climb, descent, approach and/or landing phase. Ball lightning, a metastable, rare lightning type, is also seen from and even within aircraft, but former research only reported individual incidents and did not generate a more detailed picture to ascertain whether it constitutes a significant threat to passenger and aircraft safety. Lacking established incident report channels, observations were often only passed on as "air-travel lore". In an effort to change this unsatisfactory condition, the authors have collected a first international dataset of 38 documented ball lightning aircraft incidents from 1938 to 2001 involving 13 reports over Europe, 13 over USA/Canada, and 7 over Russia. 18 (47%) reported ball lightning outside the aircraft, 18 (47%) inside, 2 cases lacked data. 8 objects caused minor damage, 8 major damage (total: 42%), only one a crash. No damage was reported in 18 cases. 3 objects caused minor crew injury. In most cases, ball lightning lasted several seconds. 11 (29%) incidents ended with an explosion of the object. A cloud-aircraft lightning flash was seen in only 9 cases (24%) of the data set. From the detailed accounts of air personnel in the last 70 years, it is evident that ball lightning is rarely, but consistently observed in connection with aircraft and can also occur inside the airframe. Reports often came from multiple professional witnesses and in several cases, damages were investigated by civil or military authorities. Although ball lightning is no main air traffic risk, the authors suggest that incident and accident

  2. Billiard-ball echo model

    NASA Astrophysics Data System (ADS)

    Beach, R.; Hartmann, S. R.; Friedberg, R.

    1982-05-01

    Photon echoes in gaseous media are explained with the use of a simple heuristic model in which the atoms behave like composite billiard balls. The laser providing the excitation pulses becomes an atom smasher which "splits" the atoms and then by judicious programming puts them back together again. The most general photon-echo reordering process is explained without recourse to formal analysis so that an intuitive feeling is obtained which works equally well for the ordinary two-pulse photon echo, the Raman echo, the trilevel echo, the grating echo, etc. A formal analysis of the billiard-ball echo model is presented in its support.

  3. Mitral valve-in-valve and valve-in-ring: technical aspects and procedural outcomes.

    PubMed

    Dvir, Danny; Webb, John

    2016-09-18

    There is a growing practice of transcatheter treatment of failed mitral valves after cardiac surgery, including valve-in-valve and valve-in-ring. Although commonly successful, these procedures can be associated with device malposition (including delayed malposition) and elevated post-procedural gradients (especially when performed inside small surgical valves). Valve-in-ring procedures have elevated risks of left ventricular outflow tract obstruction and post-procedural regurgitation. Careful patient selection and meticulous evaluation of patient anatomy and surgical implant characteristics are essential to achieve optimal clinical results with mitral valve-in-valve and valve-in-ring implantation. PMID:27640048

  4. Passively actuated valve

    DOEpatents

    Modro, S. Michael; Ougouag, Abderrafi M.

    2005-09-20

    A passively actuated valve for isolating a high pressure zone from a low pressure zone and discontinuing the isolation when the pressure in the high pressure zone drops below a preset threshold. If the pressure in the high pressure zone drops below the preset threshold, the valve opens and allows flow from the high pressure zone to the low pressure zone. The valve remains open allowing pressure equalization and back-flow should a pressure inversion between the two pressure zone occur.

  5. Aortic or Mitral Valve Replacement With the Biocor and Biocor Supra

    ClinicalTrials.gov

    2016-03-09

    Aortic Valve Insufficiency; Aortic Valve Regurgitation; Aortic Valve Stenosis; Aortic Valve Incompetence; Mitral Valve Insufficiency; Mitral Valve Regurgitation; Mitral Valve Stenosis; Mitral Valve Incompetence

  6. Magnetic Check Valve

    NASA Technical Reports Server (NTRS)

    Morris, Brian G.; Bozeman, Richard J., Jr.

    1994-01-01

    Poppet in proposed check valve restored to closed condition by magnetic attraction instead of spring force. Oscillations suppressed, with consequent reduction of wear. Stationary magnetic disk mounted just upstream of poppet, also containing magnet. Valve body nonmagnetic. Forward pressure or flow would push poppet away from stationary magnetic disk so fluid flows easily around poppet. Stop in valve body prevents poppet from being swept away. When flow stopped or started to reverse, magnetic attraction draws poppet back to disk. Poppet then engages floating O-ring, thereby closing valve and preventing reverse flow. Floating O-ring facilitates sealing at low loads.

  7. Compact gate valve

    DOEpatents

    Bobo, Gerald E.

    1977-01-01

    This invention relates to a double-disc gate valve which is compact, comparatively simple to construct, and capable of maintaining high closing pressures on the valve discs with low frictional forces. The valve casing includes axially aligned ports. Mounted in the casing is a sealed chamber which is pivotable transversely of the axis of the ports. The chamber contains the levers for moving the valve discs axially, and an actuator for the levers. When an external drive means pivots the chamber to a position where the discs are between the ports and axially aligned therewith, the actuator for the levers is energized to move the discs into sealing engagement with the ports.

  8. Triple Starr Valve Replacement

    PubMed Central

    Braimbridge, M. V.; Clement, A. J.; Brown, A. Hedley; Sabar, E.; Mendel, D.

    1969-01-01

    Of nine patients who have had triple valve replacements for organic rheumatic triple valve disease two died in the postoperative period from inadequate myocardial reserve, and a third died four months later from cerebral embolism originating from clot on the left atrial wall. The remainder are well and, except for one, leading normal lives. Though cardiac transplantation has been recommended and used successfully for triple valve disease by Cooley, it is suggested that the long-term outlook today of triple valve replacement is likely to be better than that of transplantation. ImagesFig. 1Fig. 2Fig. 3 PMID:5809243

  9. Solid handling valve

    DOEpatents

    Williams, William R.

    1979-01-01

    The present invention is directed to a solids handling valve for use in combination with lock hoppers utilized for conveying pulverized coal to a coal gasifier. The valve comprises a fluid-actuated flow control piston disposed within a housing and provided with a tapered primary seal having a recessed seat on the housing and a radially expandable fluid-actuated secondary seal. The valve seals are highly resistive to corrosion, erosion and abrasion by the solids, liquids, and gases associated with the gasification process so as to minimize valve failure.

  10. Biological heart valves.

    PubMed

    Ciubotaru, Anatol; Cebotari, Serghei; Tudorache, Igor; Beckmann, Erik; Hilfiker, Andres; Haverich, Axel

    2013-10-01

    Cardiac valvular pathologies are often caused by rheumatic fever in young adults, atherosclerosis in elderly patients, or by congenital malformation of the heart in children, in effect affecting almost all population ages. Almost 300,000 heart valve operations are performed worldwide annually. Tissue valve prostheses have certain advantages over mechanical valves such as biocompatibility, more physiological hemodynamics, and no need for life-long systemic anticoagulation. However, the major disadvantage of biological valves is related to their durability. Nevertheless, during the last decade, the number of patients undergoing biological, rather than mechanical, valve replacement has increased from half to more than three-quarters for biological implants. Continuous improvement in valve fabrication includes development of new models and shapes, novel methods of tissue treatment, and preservation and implantation techniques. These efforts are focused not only on the improvement of morbidity and mortality of the patients but also on the improvement of their quality of life. Heart valve tissue engineering aims to provide durable, "autologous" valve prostheses. These valves demonstrate adaptive growth, which may avoid the need of repeated operations in growing patients.

  11. DISCONTINUED OR LITTLE USED LARGE GATE VALVE AND VALVE ASSEMBLY ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    DISCONTINUED OR LITTLE USED LARGE GATE VALVE AND VALVE ASSEMBLY PATTERNS, PATTERN STORAGE BUILDING. - Stockham Pipe & Fittings Company, Pattern Storage, 4000 Tenth Avenue North, Birmingham, Jefferson County, AL

  12. Valve Health Monitoring System Utilizing Smart Instrumentation

    NASA Technical Reports Server (NTRS)

    Jensen, Scott L.; Drouant, George J.

    2006-01-01

    The valve monitoring system is a stand alone unit with network capabilities for integration into a higher level health management system. The system is designed for aiding in failure predictions of high-geared ball valves and linearly actuated valves. It performs data tracking and archiving for identifying degraded performance. The data collection types are cryogenic cycles, total cycles, inlet temperature, body temperature torsional strain, linear bonnet strain, preload position, total travel and total directional changes. Events are recorded and time stamped in accordance with the IRIG B True Time. The monitoring system is designed for use in a Class 1 Division II explosive environment. The basic configuration consists of several instrumentation sensor units and a base station. The sensor units are self contained microprocessor controlled and remotely mountable in three by three by two inches. Each unit is potted in a fire retardant substance without any cavities and limited to low operating power for maintaining safe operation in a hydrogen environment. The units are temperature monitored to safeguard against operation outside temperature limitations. Each contains 902-928 MHz band digital transmitters which meet Federal Communication Commission's requirements and are limited to a 35 foot transmission radius for preserving data security. The base-station controller correlates data from the sensor units and generates data event logs on a compact flash memory module for database uploading. The entries are also broadcast over an Ethernet network. Nitrogen purged National Electrical Manufactures Association (NEMA) Class 4 enclosures are used to house the base-station

  13. Mitral valve surgery - minimally invasive

    MedlinePlus

    ... valve repair - partial upper or lower sternotomy; Robotically-assisted, endoscopic valve repair, Percutaneous mitral valvuloplasty ... of your life. Biological, made of human or animal tissue. These valves last 10 to 15 years ...

  14. 2012 Problem 15: Frustrating Golf Ball

    NASA Astrophysics Data System (ADS)

    Huang, Shan; Zhu, Zheyuan; Gao, Wenli; Wang, Sihui

    2015-10-01

    This paper studies the condition for a golf ball to escape from a hole. The two determining factors are the ball's initial velocity v0 and its deviation from the center of the hole d. There is a critical escaping velocity vc for every deviation d. The ball's motion is analyzed by calculating the change of velocity whenever the ball collides with the hole. The critical conditions predicted by our theory are verified through experiment.

  15. Vertical bounce of two vertically aligned balls

    NASA Astrophysics Data System (ADS)

    Cross, Rod

    2007-11-01

    When a tennis ball rests on top of a basketball and both drop to the floor together, the tennis ball is projected vertically at high speed. A mass-spring model of the impact, as well as air track data, suggest that the tennis ball should be projected at relatively low speed. Measurements of the forces on each ball and the bounce of vertically aligned superballs are used to resolve the discrepancy.

  16. Silicon Nitride Balls For Cryogenic Bearings

    NASA Technical Reports Server (NTRS)

    Butner, Myles F.; Ng, Lillian W.

    1990-01-01

    Resistance to wear greater than that of 440C steel. Experiments show lives of ball bearings immersed in liquid nitrogen or liquid oxygen increased significantly when 440C steel balls (running on 440C steel races) replaced by balls of silicon nitride. Developed for use at high temperatures, where lubrication poor or nonexistent. Best wear life of any bearing tested to date and ball material spalls without fracturing. Plans for future tests call for use of liquid oxygen as working fluid.

  17. Does Ease to Block a Ball Affect Perceived Ball Speed? Examination of Alternative Hypotheses

    ERIC Educational Resources Information Center

    Witt, Jessica K.; Sugovic, Mila

    2012-01-01

    According to an action-specific account of perception, the perceived speed of a ball can be a function of the ease to block the ball. Balls that are easier to stop look like they are moving slower than balls that are more difficult to stop. This was recently demonstrated with a modified version of the classic computer game Pong (Witt & Sugovic,…

  18. Secrets of the Crystal Ball

    ERIC Educational Resources Information Center

    Croucher, John S.

    2007-01-01

    This article describes how a crystal ball known as "The Flash Mind Reader" is played. "The Flash Mind Reader" is a mathematics game in which the player is invited to select any-two digit number and then subtract the sum of these two digits from the original number. A chart is provided in which the (adjusted) number they obtained will have a symbol…

  19. Laboratory-produced ball lightning

    NASA Astrophysics Data System (ADS)

    Golka, Robert K., Jr.

    1994-05-01

    For 25 years I have actively been searching for the true nature of ball lightning and attempting to reproduce it at will in the laboratory. As one might expect, many unidentified lights in the atmosphere have been called ball lightning, including Texas Maffa lights (automobile headlights), flying saucers (UFOs), swamp gas in Ann Arbor, Michigan, etc. For 15 years I thought ball lightning was strictly a high-voltage phenomenon. It was not until 1984 when I was short-circuiting the electrical output of a diesel electric railroad locomotive that I realized that the phenomenon was related more to a high current. Although I am hoping for some other types of ball lightning to emerge such as strictly electrostatic-electromagnetic manifestations, I have been unlucky in finding laboratory provable evidence. Cavity-formed plasmodes can be made by putting a 2-inch burning candle in a home kitchen microwave oven. The plasmodes float around for as long as the microwave energy is present.

  20. The correct "ball bearings" data.

    PubMed

    Caroni, C

    2002-12-01

    The famous data on fatigue failure times of ball bearings have been quoted incorrectly from Lieblein and Zelen's original paper. The correct data include censored values, as well as non-fatigue failures that must be handled appropriately. They could be described by a mixture of Weibull distributions, corresponding to different modes of failure.

  1. Idea Bank: Wiffle Ball Physics

    ERIC Educational Resources Information Center

    Lancor, Rachael

    2009-01-01

    Projectile motion, a cornerstone topic of introductory physics, is usually a student's first exposure to the problem-solving techniques used in this subject. Often, this is an inactive learning experience--students work with pencil and paper to read and solve projectile motion problems (e.g., diagrams and descriptions of balls being hit, kicked,…

  2. Eddy-Current Inspection of Ball Bearings

    NASA Technical Reports Server (NTRS)

    Bankston, B.

    1985-01-01

    Custom eddy-current probe locates surface anomalies. Low friction air cushion within cone allows ball to roll easily. Eddy current probe reliably detects surface and near-surface cracks, voids, and material anomalies in bearing balls or other spherical objects. Defects in ball surface detected by probe displayed on CRT and recorded on strip-chart recorder.

  3. Playing Ball in a Space Station

    ERIC Educational Resources Information Center

    Simoson, Andrew J.

    2006-01-01

    How does artificial gravity affect the path of a thrown ball? This paper contrasts ball trajectories on the Little Prince's asteroid planet B-612 and Arthur C. Clarke's rotating-drum spacecraft of 2001, and demonstrates curve balls with multiple loops in the latter environment.

  4. Non-plugging injection valve

    DOEpatents

    Carey, Jr., Henry S.

    1985-01-01

    A valve for injecting fluid into a conduit carrying a slurry subject to separation to form deposits capable of plugging openings into the conduit. The valve comprises a valve body that is sealed to the conduit about an aperture formed through the wall of the conduit to receive the fluid to be injected and the valve member of the valve includes a punch portion that extends through the injection aperture to the flow passage, when the valve is closed, to provide a clear channel into the conduit, when the valve is opened, through deposits which might have formed on portions of the valve adjacent the conduit.

  5. How Is Heart Valve Disease Treated?

    MedlinePlus

    ... and replacing it with a man-made or biological valve. Biological valves are made from pig, cow, or human ... the valve. Man-made valves last longer than biological valves and usually don’t have to be ...

  6. Shutoff and throttling valve

    NASA Technical Reports Server (NTRS)

    Hays, L. G.

    1974-01-01

    Leaktight shutoff, precise flow control, and very low pressure drop are incorporated in all-metal valve designed for operation under extreme temperatures. Valve constructed with refractory metal is intended for control of high-temperature liquid cesium, but has applications related to control of high- and low-temperature liquids and gases.

  7. Simple, Internally Adjustable Valve

    NASA Technical Reports Server (NTRS)

    Burley, Richard K.

    1990-01-01

    Valve containing simple in-line, adjustable, flow-control orifice made from ordinary plumbing fitting and two allen setscrews. Construction of valve requires only simple drilling, tapping, and grinding. Orifice installed in existing fitting, avoiding changes in rest of plumbing.

  8. Heimlich valve and pneumothorax

    PubMed Central

    Gogakos, Apostolos; Barbetakis, Nikolaos; Lazaridis, George; Papaiwannou, Antonis; Karavergou, Anastasia; Lampaki, Sofia; Baka, Sofia; Mpoukovinas, Ioannis; Karavasilis, Vasilis; Kioumis, Ioannis; Pitsiou, Georgia; Katsikogiannis, Nikolaos; Tsakiridis, Kosmas; Rapti, Aggeliki; Trakada, Georgia; Zissimopoulos, Athanasios; Tsirgogianni, Katerina; Zarogoulidis, Konstantinos

    2015-01-01

    The Heimlich valve is a small one-way valve used for chest drainage that empties into a flexible collection device and prevents return of gases or fluids into the pleural space. The Heimlich valve is less than 13 cm (5 inches) long and facilitates patient ambulation. Currently there are several systems in the market. It can be used in many patients instead of a traditional water seal drainage system. The Heimlich chest drainage valve was developed so that the process of draining the pleural cavity could be accomplished in a safe, relatively simple, and efficient manner. This valve system has replaced the cumbersome underwater drainage bottle system. Moreover; the Heimlich valve system connects to chest tubing and allows fluid and air to pass in one direction only. This system functions in any position, and it does not ever need to be clamped, a regulated suction can be attached to it if necessary. The valve drains into a plastic bag that can be held at any level, allowing the patient undergoing chest drainage to be ambulatory simply by carrying the bag. In the current mini review we will present the Heimlich valve system and method of insertion. PMID:25861609

  9. Linear motion valve

    NASA Technical Reports Server (NTRS)

    Chandler, J. A. (Inventor)

    1985-01-01

    The linear motion valve is described. The valve spool employs magnetically permeable rings, spaced apart axially, which engage a sealing assembly having magnetically permeable pole pieces in magnetic relationship with a magnet. The gap between the ring and the pole pieces is sealed with a ferrofluid. Depletion of the ferrofluid is minimized.

  10. Space Vehicle Valve System

    NASA Technical Reports Server (NTRS)

    Kelley, Anthony R. (Inventor); Lindner, Jeffrey L. (Inventor)

    2014-01-01

    The present invention is a space vehicle valve system which controls the internal pressure of a space vehicle and the flow rate of purged gases at a given internal pressure and aperture site. A plurality of quasi-unique variable dimension peaked valve structures cover the purge apertures on a space vehicle. Interchangeable sheet guards configured to cover valve apertures on the peaked valve structure contain a pressure-activated surface on the inner surface. Sheet guards move outwardly from the peaked valve structure when in structural contact with a purge gas stream flowing through the apertures on the space vehicle. Changing the properties of the sheet guards changes the response of the sheet guards at a given internal pressure, providing control of the flow rate at a given aperture site.

  11. Multiple-port valve

    DOEpatents

    Doody, Thomas J.

    1978-08-22

    A multiple-port valve assembly is designed to direct flow from a primary conduit into any one of a plurality of secondary conduits as well as to direct a reverse flow. The valve includes two mating hemispherical sockets that rotatably receive a spherical valve plug. The valve plug is attached to the primary conduit and includes diverging passageways from that conduit to a plurality of ports. Each of the ports is alignable wih one or more of a plurality of secondary conduits fitted into one of the hemispherical sockets. The other hemispherical socket includes a slot for the primary conduit such that the conduit's motion along that slot with rotation of the spherical plug about various axes will position the valve-plug ports in respect to the secondary conduits.

  12. Fuel injection valve connection

    SciTech Connect

    Eshleman, E.S.; Field, M.J.; Penwright, J.L.

    1987-09-15

    A fuel injection valve connection is described which consists of a fuel injection valve having a cylindrical inlet fitting. The fitting has a threaded internal surface and a cylindrical external surface. A fuel connector has a projection with a threaded external surface that mates with the threaded internal surface of the fitting. The connector also has a sleeve with a cylindrical internal surface surrounding the fitting and an O-ring sealingly engaging the internal surface of the sleeve and the external surface of the fitting, whereby the valve may be rotated relative to the connector without breaking the sealing engagement between the valve and the connector, and wherein the connector also has a tab engageable with the injector to prevent unthreading of the valve from the connector.

  13. How to catch a cricket ball.

    PubMed

    Dienes, Z; McLeod, P

    1993-01-01

    A cricket or baseball fielder can run so as to arrive at just the right place at just the right time to catch a ball. It is shown that if the fielder runs so that d2(tan alpha)/dt2 = 0, where alpha is the angle of elevation of gaze from fielder to ball, then the ball will generally be intercepted before it hits the ground. This is true whatever the aerodynamic drag experienced by the ball. The only exception is if the ball is not approaching the fielder before he starts to run.

  14. Fate of thermal log type Q balls

    SciTech Connect

    Chiba, Takeshi; Kamada, Kohei; Kasuya, Shinta; Yamaguchi, Masahide

    2010-11-15

    We study time evolution of the Q ball in thermal logarithmic potential using lattice simulations. As the temperature decreases due to the cosmic expansion, the thermal logarithmic term in the potential is eventually overcome by a mass term, and we confirm that the Q ball transforms from the thick-wall type to the thin-wall type for a positive coefficient of radiative corrections to the mass term, as recently suggested. Moreover, we find that the Q ball finally ''melts down'' when the Q-ball solution disappears. We also discuss the effects of this phenomenon on the detectability of gravitational waves from the Q-ball formation.

  15. Ceramic Rail-Race Ball Bearings

    NASA Technical Reports Server (NTRS)

    Balzer, Mark A.; Mungas, Greg S.; Peters, Gregory H.

    2010-01-01

    Non-lubricated ball bearings featuring rail races have been proposed for use in mechanisms that are required to function in the presence of mineral dust particles in very low-pressure, dry environments with extended life. Like a conventional ball bearing, the proposed bearing would include an inner and an outer ring separated by balls in rolling contact with the races. However, unlike a conventional ball bearing, the balls would not roll in semi-circular or gothic arch race grooves in the rings: instead, the races would be shaped to form two or more rails (see figure). During operation, the motion of the balls would push dust particles into the spaces between the rails where the particles could not generate rolling resistance for the balls

  16. Polymer-composite ball lightning.

    PubMed

    Bychkov, V L

    2002-01-15

    Investigations into the state of ball lightning (BL) have been made, and both theory and experiments, related to so-called "polymer-composite" ball lightning, are presented. The properties of such a polymeric BL have been described and are that of a long-lived object capable of storing high energy. Results of experiments, starting with polymeric components in erosive gas discharge experiments, are described and discussed. The model of BL as a highly charged polymer-dielectric structure is described. According to this model BL appears as the result of the aggregation of natural polymers, such as lignin and cellulose, soot, polymeric silica and other natural dust particles. Its ability to glow is explained by the appearance over its perimeter of gas discharges near the highly charged BL surface, and electrical breakdown of some regions on the surface, consisting of polymerized and aggregated threads.

  17. Polymer-composite ball lightning.

    PubMed

    Bychkov, V L

    2002-01-15

    Investigations into the state of ball lightning (BL) have been made, and both theory and experiments, related to so-called "polymer-composite" ball lightning, are presented. The properties of such a polymeric BL have been described and are that of a long-lived object capable of storing high energy. Results of experiments, starting with polymeric components in erosive gas discharge experiments, are described and discussed. The model of BL as a highly charged polymer-dielectric structure is described. According to this model BL appears as the result of the aggregation of natural polymers, such as lignin and cellulose, soot, polymeric silica and other natural dust particles. Its ability to glow is explained by the appearance over its perimeter of gas discharges near the highly charged BL surface, and electrical breakdown of some regions on the surface, consisting of polymerized and aggregated threads. PMID:16210170

  18. Transcatheter aortic valve implantation.

    PubMed

    Kapadia, Samir R; Tuzcu, E Murat

    2009-12-01

    Aortic stenosis is the most important valvular heart disease affecting the elderly population. Surgical aortic valve replacement is the mainstay of treatment, although a substantial number of patients are considered high risk for surgery. Many of these patients do not undergo surgery and have poor outcomes from medically treated symptomatic, severe aortic stenosis. Transcatheter aortic valve implantation (TAVI) provides a promising treatment option for some of these patients. Several devices are under investigation. The Edwards Sapien valve (Edwards Lifesciences, Irvine, CA) and the CoreValve (Medtronic, Minneapolis, MN) have the largest human experience to date. Initial data suggest that these devices have an acceptable safety profile and provide excellent hemodynamic relief of aortic stenosis. The Edwards Sapien valve is currently under investigation in the United States in the PARTNER (Placement of Aortic Transcatheter Valve) trial in high-risk surgical or inoperable patients; TAVI is available for clinical use in both Canada and Europe. TAVI is not used in low- or intermediate-risk surgical patients; however, future studies may prove its applicability in these subsets. The major complications of TAVI include access site-related problems and device malpositioning/migration. There are several new-generation prosthetic valves and delivery systems designed to be low profile and repositionable. Technical advances and refinement of the implantation methods may make TAVI even safer and ultimately a better treatment option, not only for patients with high surgical risk but also for those with moderate or low risk.

  19. Improve relief valve reliability

    SciTech Connect

    Nelson, W.E.

    1993-01-01

    This paper reports on careful evaluation of safety relief valves and their service conditions which can improve reliability and permit more time between testing. Some factors that aid in getting long-run results are: Use of valves suitable for service, Attention to design of the relieving system (including use of block valves) and Close attention to repair procedures. Use these procedures for each installation, applying good engineering practices. The Clean Air Act of 1990 and other legislation limiting allowable fugitive emissions in a hydrocarbon processing plant will greatly impact safety relief valve installations. Normal leakage rate from a relief valve will require that it be connected to a closed vent system connected to a recovery or control device. Tying the outlet of an existing valve into a header system can cause accelerated corrosion and operating difficulties. Reliability of many existing safety relief valves may be compromised when they are connected to an outlet header without following good engineering practices. The law has been enacted but all the rules have not been promulgated.

  20. Computational valve plate design

    NASA Astrophysics Data System (ADS)

    Kalbfleisch, Paul

    Axial piston machines are widely used in many industries for their designs compactness, flexibility in power transfer, variable flow rate, and high efficiencies as compared to their manufacturing costs. One important component of all axial piston machines that is a very influential on the performance of the unit is the valve plate. The aim of this research is to develop a design methodology that is general enough to design all types of valve plates and the simple enough not to require advanced technical knowledge from the user. A new style of valve plate designs has been developed that comprehensively considers all previous design techniques and does not require significant changes to the manufacturing processes of valve plates. The design methodology utilizes a previously developed accurate computer model of the physical phenomenon. This allows the precise optimization of the valve plate design through the use of simulations rather than expensive trial and error processes. The design of the valve plate is clarified into the form of an optimization problem. This formulation into an optimization problem has motivated the selection of an optimization algorithm that satisfies the requirements of the design. The proposed design methodology was successfully tested in a case study in the shown to be very successful in improving required performance of the valve plate design.

  1. Keeping your eyes continuously on the ball while running for catchable and uncatchable fly balls.

    PubMed

    Postma, Dees B W; den Otter, A Rob; Zaal, Frank T J M

    2014-01-01

    When faced with a fly ball approaching along the sagittal plane, fielders need information for the control of their running to the interception location. This information could be available in the initial part of the ball trajectory, such that the interception location can be predicted from its initial conditions. Alternatively, such predictive information is not available, and running to the interception location involves continuous visual guidance. The latter type of control would predict that fielders keep looking at the approaching ball for most of its flight, whereas the former type of control would fit with looking at the ball during the early part of the ball's flight; keeping the eyes on the ball during the remainder of its trajectory would not be necessary when the interception location can be inferred from the first part of the ball trajectory. The present contribution studied visual tracking of approaching fly balls. Participants were equipped with a mobile eye tracker. They were confronted with tennis balls approaching from about 20 m, and projected in such a way that some balls were catchable and others were not. In all situations, participants almost exclusively tracked the ball with their gaze until just before the catch or until they indicated that a ball was uncatchable. This continuous tracking of the ball, even when running close to their maximum speeds, suggests that participants employed continuous visual control rather than running to an interception location known from looking at the early part of the ball flight. PMID:24670972

  2. Keeping Your Eyes Continuously on the Ball While Running for Catchable and Uncatchable Fly Balls

    PubMed Central

    Postma, Dees B. W.; den Otter, A. Rob; Zaal, Frank T. J. M.

    2014-01-01

    When faced with a fly ball approaching along the sagittal plane, fielders need information for the control of their running to the interception location. This information could be available in the initial part of the ball trajectory, such that the interception location can be predicted from its initial conditions. Alternatively, such predictive information is not available, and running to the interception location involves continuous visual guidance. The latter type of control would predict that fielders keep looking at the approaching ball for most of its flight, whereas the former type of control would fit with looking at the ball during the early part of the ball's flight; keeping the eyes on the ball during the remainder of its trajectory would not be necessary when the interception location can be inferred from the first part of the ball trajectory. The present contribution studied visual tracking of approaching fly balls. Participants were equipped with a mobile eye tracker. They were confronted with tennis balls approaching from about 20 m, and projected in such a way that some balls were catchable and others were not. In all situations, participants almost exclusively tracked the ball with their gaze until just before the catch or until they indicated that a ball was uncatchable. This continuous tracking of the ball, even when running close to their maximum speeds, suggests that participants employed continuous visual control rather than running to an interception location known from looking at the early part of the ball flight. PMID:24670972

  3. How to create ball lightning

    NASA Technical Reports Server (NTRS)

    Golka, Robert K., Jr.

    1991-01-01

    Procedures are given on how to produce ball lightning. Necessary equipment includes a transformer of 150,000 watts capable of providing approximately 10,000 amperes at 15 volts, 60 cycles; thick one inch cables of stranded wire leading into a 3 by 4 by 1 foot plastic tank; a quarter inch thick 4 by 6 inch aluminum plate to be used as one of the discharge electrodes; and another electrode of heavy copper wire with the insulation stripped back 6 inches.

  4. Falling Sticks and Falling Balls

    NASA Astrophysics Data System (ADS)

    Bacon, M. E.; Harpst, Michael R.; Nakazawa, Ryohei

    2002-09-01

    The behavior of a falling stick, pivoted at one end, and a ball released from the same height as the end of the stick, is investigated theoretically and experimentally. The study is made possible through the use of the computer to perform the numerical computations and analysis of the experimental data. The study provides undergraduates with an opportunity to carry out a relatively simple project with interesting results.

  5. Valve body for oilfield applications

    SciTech Connect

    Bailey, T.F.; Campbell, J.E.

    1992-01-21

    This patent describes a valve to pump fluids, save valve sealingly cooperating with a valve set having a throughbore. It comprises a valve head having an axial cavity with an interior annular side wall; a valve body attached to the valve head, the valve body including an axial neck portion received within the cavity of the valve head and having an outer annular surface corresponding to the interior annular side wall of the cavity; and means to lockingly attach the valve body to the valve head, the valve head being made of a metal material and the valve body being made of an elastomer material, the locking means including at least one annular tongue formed on the outer annular surface of the neck portion of the valve body, the at least one tongue having a frusto-conical upper surface, a cylindrical intermediate surface and a curved lower surface the at least one annular tongue lockingly engaging at least one corresponding annular groove formed in the interior annular side wall of the internal cavity of the valve head thereby preventing inadvertent withdrawal of the neck portion from the cavity and separation of the valve body from the valve head.

  6. Face-Sealing Butterfly Valve

    NASA Technical Reports Server (NTRS)

    Tervo, John N.

    1992-01-01

    Valve plate made to translate as well as rotate. Valve opened and closed by turning shaft and lever. Interactions among lever, spring, valve plate, and face seal cause plate to undergo combination of translation and rotation so valve plate clears seal during parts of opening and closing motions.

  7. Sliding-gate valve

    DOEpatents

    Usnick, George B.; Ward, Gene T.; Blair, Henry O.; Roberts, James W.; Warner, Terry N.

    1979-01-01

    This invention is a novel valve of the slidable-gate type. The valve is designed especially for long-term use with highly abrasive slurries. The sealing surfaces of the gate are shielded by the valve seats when the valve is fully open or closed, and the gate-to-seat clearance is swept with an inflowing purge gas while the gate is in transit. A preferred form of the valve includes an annular valve body containing an annular seat assembly defining a flow channel. The seat assembly comprises a first seat ring which is slidably and sealably mounted in the body, and a second seat ring which is tightly fitted in the body. These rings cooperatively define an annular gap which, together with passages in the valve body, forms a guideway extending normal to the channel. A plate-type gate is mounted for reciprocation in the guideway between positions where a portion of the plate closes the channel and where a circular aperture in the gate is in register with the channel. The valve casing includes opposed chambers which extend outwardly from the body along the axis of the guideway to accommodate the end portions of the gate. The chambers are sealed from atmosphere; when the gate is in transit, purge gas is admitted to the chambers and flows inwardly through the gate-to-seat-ring, clearance, minimizing buildup of process solids therein. A shaft reciprocated by an external actuator extends into one of the sealed chambers through a shaft seal and is coupled to an end of the gate. Means are provided for adjusting the clearance between the first seat ring and the gate while the valve is in service.

  8. 2013 Problem 3: Bouncing Ball

    NASA Astrophysics Data System (ADS)

    Xiong, Bo; Du, Li; Wang, Sihui; Gao, Wenli

    2015-10-01

    In this solution, we study the rebound of a liquid-filled Ping-Pong ball after a free-fall motion. We classify the collision into "rigid-like motion" or "liquid-involved" motion. The most significant parameter is the amount of water. The rebounding height is suppressed most as the amount of water is about half of the total volume, exhibiting a typical "liquid-involved" motion. As the amount of water increases further, the rebounding height gradually recovers, and the ball becomes rigid again. We build a theoretical model to interpret the phenomenon. The model describes the formation of the flow field during the collision stage based on the momentum propagation and flux conservation of the liquid. An effective mass is introduced to describe the confinement effect on water by the sphere. Our model successfully predicts the bouncing height with respect to the amount of water. Releasing height is also an important parameter in determining the "nature of collision". As the releasing height increases, the whole system tends to become more and more "rigid". We classify the nature of collision above a certain releasing height as "rigid-like" regardless of the amount of water inside the ball.

  9. Long life valve design concepts

    NASA Technical Reports Server (NTRS)

    Jones, J. R.; Hall, A. H., Jr.

    1975-01-01

    Valve concept evaluation, final candidate selection, design, manufacture, and demonstration testing of a pneumatically actuated 10-inch hybrid poppet butterfly shutoff valve are presented. Conclusions and recommendations regarding those valve characteristics and features which would serve to guide in the formulation of future valve procurements are discussed. The pertinent design goals were temperature range of plus 200 to minus 423 F, valve inlet pressure 35 psia, actuation pressure 750 psia, main seal leakage 3 x 0.00001 sccs at 35 psia valve inlet pressure, and a storage and operating life of 10 years. The valve was designed to be compatible with RP-1, propane, LH2, LO2, He, and N2.

  10. Percutaneous Pulmonary Valve Placement

    PubMed Central

    Prieto, Lourdes R.

    2015-01-01

    Patients with congenital heart disease and pulmonary valve disease need multiple procedures over their lifetimes to replace their pulmonary valves. Chronic pulmonary stenosis, regurgitation, or both have untoward effects on ventricular function and on the clinical status of these patients. To date, all right ventricle–pulmonary artery conduits have had relatively short lifespans. Percutaneous pulmonary valve implantation, although relatively new, will probably reduce the number of operative procedures that these patients will have to undergo over a lifetime. Refinement and further development of this procedure holds promise for the extension of this technology to other patient populations. PMID:26175629

  11. Performance of needle valves.

    PubMed

    Hutton, P; Boaden, R W

    1986-08-01

    The pressure-flow characteristics of needle valves used on anaesthetic equipment were investigated. It was found that, under normal conditions of use, the valves behaved in a manner similar to convergent nozzles with sonic velocity at the throat. This means that, once the valve has been set, the mass flow rate of gas is effectively independent of the downstream changes in resistance and compliance encountered in normal anaesthetic practice. The error in a preset flow induced by the permissible variations in the upstream pipeline pressure was measured.

  12. Ball Screw Actuator Including a Stop with an Integral Guide

    NASA Technical Reports Server (NTRS)

    Wingett, Paul T. (Inventor); Perek, John (Inventor); Geck, Kellan (Inventor)

    2015-01-01

    An actuator includes a housing assembly, a ball nut, a ball screw, and a ball screw stop. The ball nut is rotationally mounted in the housing assembly, is adapted to receive an input torque, and is configured, upon receipt thereof, to rotate and supply a drive force. The ball screw is mounted within the housing assembly and extends through the ball nut. The ball screw has a first end and a second end, and is coupled to receive the drive force from the ball nut. The ball screw is configured, upon receipt of the drive force, to selectively translate between a stow position and a deploy position. The ball screw stop is mounted on the ball screw to translate therewith and is configured to at selectively engage the housing assembly while the ball screw is translating, and engage the ball nut when the ball screw is in the deploy position.

  13. Mesofluidic two stage digital valve

    DOEpatents

    Jansen, John F; Love, Lonnie J; Lind, Randall F; Richardson, Bradley S

    2013-12-31

    A mesofluidic scale digital valve system includes a first mesofluidic scale valve having a valve body including a bore, wherein the valve body is configured to cooperate with a solenoid disposed substantially adjacent to the valve body to translate a poppet carried within the bore. The mesofluidic scale digital valve system also includes a second mesofluidic scale valve disposed substantially perpendicular to the first mesofluidic scale valve. The mesofluidic scale digital valve system further includes a control element in communication with the solenoid, wherein the control element is configured to maintain the solenoid in an energized state for a fixed period of time to provide a desired flow rate through an orifice of the second mesofluidic valve.

  14. Precise timing when hitting falling balls.

    PubMed

    Brenner, Eli; Driesen, Ben; Smeets, Jeroen B J

    2014-01-01

    People are extremely good at hitting falling balls with a baseball bat. Despite the ball's constant acceleration, they have been reported to time hits with a standard deviation of only about 7 ms. To examine how people achieve such precision, we compared performance when there were no added restrictions, with performance when looking with one eye, when vision was blurred, and when various parts of the ball's trajectory were hidden from view. We also examined how the size of the ball and varying the height from which it was dropped influenced temporal precision. Temporal precision did not become worse when vision was blurred, when the ball was smaller, or when balls falling from different heights were randomly interleaved. The disadvantage of closing one eye did not exceed expectations from removing one of two independent estimates. Precision was higher for slower balls, but only if the ball being slower meant that one saw it longer before the hit. It was particularly important to see the ball while swinging the bat. Together, these findings suggest that people time their hits so precisely by using the changing elevation throughout the swing to adjust the bat's movement to that of the ball. PMID:24904380

  15. Precise timing when hitting falling balls

    PubMed Central

    Brenner, Eli; Driesen, Ben; Smeets, Jeroen B. J.

    2014-01-01

    People are extremely good at hitting falling balls with a baseball bat. Despite the ball's constant acceleration, they have been reported to time hits with a standard deviation of only about 7 ms. To examine how people achieve such precision, we compared performance when there were no added restrictions, with performance when looking with one eye, when vision was blurred, and when various parts of the ball's trajectory were hidden from view. We also examined how the size of the ball and varying the height from which it was dropped influenced temporal precision. Temporal precision did not become worse when vision was blurred, when the ball was smaller, or when balls falling from different heights were randomly interleaved. The disadvantage of closing one eye did not exceed expectations from removing one of two independent estimates. Precision was higher for slower balls, but only if the ball being slower meant that one saw it longer before the hit. It was particularly important to see the ball while swinging the bat. Together, these findings suggest that people time their hits so precisely by using the changing elevation throughout the swing to adjust the bat's movement to that of the ball. PMID:24904380

  16. Precise timing when hitting falling balls.

    PubMed

    Brenner, Eli; Driesen, Ben; Smeets, Jeroen B J

    2014-01-01

    People are extremely good at hitting falling balls with a baseball bat. Despite the ball's constant acceleration, they have been reported to time hits with a standard deviation of only about 7 ms. To examine how people achieve such precision, we compared performance when there were no added restrictions, with performance when looking with one eye, when vision was blurred, and when various parts of the ball's trajectory were hidden from view. We also examined how the size of the ball and varying the height from which it was dropped influenced temporal precision. Temporal precision did not become worse when vision was blurred, when the ball was smaller, or when balls falling from different heights were randomly interleaved. The disadvantage of closing one eye did not exceed expectations from removing one of two independent estimates. Precision was higher for slower balls, but only if the ball being slower meant that one saw it longer before the hit. It was particularly important to see the ball while swinging the bat. Together, these findings suggest that people time their hits so precisely by using the changing elevation throughout the swing to adjust the bat's movement to that of the ball.

  17. Mitral valve prolapse

    MedlinePlus

    ... to keep blood from moving backwards when the heart beats (contracts). Mitral valve prolapse is the term used ... Dizziness Fatigue Panic attacks Sensation of feeling the heart beat ( palpitations ) Shortness of breath with activity or when ...

  18. Transcatheter Aortic Valve Implantation.

    PubMed

    Malaisrie, S Chris; Iddriss, Adam; Flaherty, James D; Churyla, Andrei

    2016-05-01

    Severe aortic stenosis (AS) is a life-threatening condition when left untreated. Aortic valve replacement (AVR) is the gold standard treatment for the majority of patients; however, transcatheter aortic valve implantation/replacement (TAVI/TAVR) has emerged as the preferred treatment for high-risk or inoperable patients. The concept of transcatheter heart valves originated in the 1960s and has evolved into the current Edwards Sapien and Medtronic CoreValve platforms available for clinical use. Complications following TAVI, including cerebrovascular events, perivalvular regurgitation, vascular injury, and heart block have decreased with experience and evolving technology, such that ongoing trials studying TAVI in lower risk patients have become tenable. The multidisciplinary team involving the cardiac surgeon and cardiologist plays an essential role in patient selection, procedural conduct, and perioperative care.

  19. Mitral Valve Prolapse.

    ERIC Educational Resources Information Center

    Bergy, Gordon G.

    1980-01-01

    Mitral valve prolapse is the most common heart disease seen in college and university health services. It underlies most arrhythmia and many chest complaints. Activity and exercise restrictions are usually unnecessary. (Author/CJ)

  20. Flow metering valve

    DOEpatents

    Blaedel, Kenneth L.

    1985-01-01

    An apparatus for metering fluids at high pressures of about 20,000 to 60,000 psi is disclosed. The apparatus includes first and second plates which are positioned adjacent each other to form a valve chamber. The plates are made of materials which have substantially equal elastic properties. One plate has a planar surface area, and the other a recessed surface area defined by periphery and central lips. When the two plates are positioned in adjacent contacting relationship, a valve chamber is formed between the planar surface area and the recessed surface area. Fluid is introduced into the chamber and exits therefrom when a deformation occurs at positions where they no longer form a valve seat. This permits the metering of fluids at high pressures and at slow variable rates. Fluid then exits from the chamber until an applied external force becomes large enough to bring the valve seats back into contact.

  1. Valve Repair or Replacement

    MedlinePlus

    ... valve surgery can be done using a robot. Robotic surgery does not require a large incision in ... The Texas Heart Institute has a robot. With robotic surgery, the surgeon has a control console, a ...

  2. Bidirectional piston valve

    DOEpatents

    Fischer, Harry C.

    1977-01-01

    This invention is a reversing valve having an inlet, an outlet, and an inlet-outlet port. The valve is designed to respond to the introduction of relatively high-pressure fluid at its inlet or, alternatively, of lower-pressure fluid at its inlet-outlet port. The valve includes an axially slidable assembly which is spring-biased to a position where it isolates the inlet and connects the inlet-outlet port to the outlet. The admission of high-pressure fluid to the inlet displaces the slidable assembly to a position where the outlet is isolated and the inlet is connected to the inlet-outlet port. The valve is designed to minimize pressure drops and leakage. It is of a reliable and comparatively simple design.

  3. THERMALLY OPERATED VAPOR VALVE

    DOEpatents

    Dorward, J.G. Jr.

    1959-02-10

    A valve is presented for use in a calutron to supply and control the vapor to be ionized. The invention provides a means readily operable from the exterior of the vacuum tank of the apparatuss without mechanical transmission of forces for the quick and accurate control of the ionizing arc by a corresponding control of gas flow theretos thereby producing an effective way of carefully regulating the operation of the calutron. The invention consists essentially of a tube member extending into the charge bottle of a calutron devices having a poppet type valve closing the lower end of the tube. An electrical heating means is provided in the valve stem to thermally vary the length of the stem to regulate the valve opening to control the flow of material from the charge bottle.

  4. Flow metering valve

    DOEpatents

    Blaedel, K.L.

    1983-11-03

    An apparatus for metering fluids at high pressures of about 20,000 to 60,000 psi is disclosed. The apparatus includes first and second plates which are positioned adjacent each other to form a valve chamber. The plates are made of materials which have substantially equal elastic properties. One plate has a planar surface area, and the other a recessed surface area defined by periphery and central lips. When the two plates are positioned in adjacent contacting relationship, a valve chamber is formed between the planar surface area and the recessed surface area. Fluid is introduced into the chamber and exits therefrom when a deformation occurs at positions where they no longer form a valve seat. This permits the metering of fluids at high pressures and at slow variable rates. Fluid then exits from the chamber until an applied external force becomes large enough to bring the valve seats back into contact.

  5. When a Mechanical Valve Goes Freestyle: A Patient Tailored Valve-In-Valve Implantation.

    PubMed

    François, J; Cathenis, K; Hamerlijnck, R

    2015-01-01

    In case of a redo operation after a full root replacement there are two possible options: replacing the entire root or performing a more conservative valve-in-valve implantation. Regarding the relatively high morbidity and mortality of a redo root replacement, the valve-in-valve implantation is the preferred choice if technically feasible. We present the case of a valve-in-valve implantation with a St. Jude mechanical valve in a Medtronic bioprosthesis in a 57-year old man. Follow-up echocardiography after 1 month showed a mean gradient of 17 mmHg and no paravalvular leakage. The combination of a St. Jude bileaflet mechanical valve implanted in a Freestyle root prosthesis has not been described. This case shows that patient tailored treatment with a St. Jude bileaflet mechanical valve in a Freestyle aortic root valve can be safely performed and might be the preferred choice for younger patients, if technically feasible. PMID:26560005

  6. Fluid Mechanics of Cricket and Tennis Balls

    NASA Astrophysics Data System (ADS)

    Mehta, Rabindra D.

    2009-11-01

    Aerodynamics plays a prominent role in defining the flight of a ball that is struck or thrown through the air in almost all ball sports. The main interest is in the fact that the ball can often deviate from its initial straight path, resulting in a curved, or sometimes an unpredictable, flight path. It is particularly fascinating that that not all the parameters that affect the flight of a ball are always under human influence. Lateral deflection in flight, commonly known as swing, swerve or curve, is well recognized in cricket and tennis. In tennis, the lateral deflection is produced by spinning the ball about an axis perpendicular to the line of flight, which gives rise to what is commonly known as the Magnus effect. It is now well recognized that the aerodynamics of sports balls are strongly dependent on the detailed development and behavior of the boundary layer on the ball's surface. A side force, which makes a ball curve through the air, can also be generated in the absence of the Magnus effect. In one of the cricket deliveries, the ball is released with the seam angled, which trips the laminar boundary layer into a turbulent state on that side. The turbulent boundary layer separates relatively late compared to the laminar layer on the other side, thereby creating a pressure difference and hence side force. The fluid mechanics of a cricket ball become very interesting at the higher Reynolds numbers and this will be discussed in detail. Of all the round sports balls, a tennis ball has the highest drag coefficient. This will be explained in terms of the contribution of the ``fuzz" drag and how that changes with Reynolds number and ball surface wear. It is particularly fascinating that, purely through historical accidents, small disturbances on the ball surface, such as the stitching on cricket balls and the felt cover on tennis balls are all about the right size to affect boundary layer transition and development in the Reynolds numbers of interest. The fluid

  7. Valve for gas centrifuges

    DOEpatents

    Hahs, Charles A.; Burbage, Charles H.

    1984-01-01

    The invention is a pneumatically operated valve assembly for simultaneously (1) closing gas-transfer lines connected to a gas centrifuge or the like and (2) establishing a recycle path between two of the lines so closed. The valve assembly is especially designed to be compact, fast-acting, reliable, and comparatively inexpensive. It provides large reductions in capital costs for gas-centrifuge cascades.

  8. Electric charge of a lightning ball

    NASA Astrophysics Data System (ADS)

    Grigor'ev, A. I.; Shiryaeva, S. O.; Petrushov, N. A.

    2016-09-01

    The electric charge of a lightning ball is found by comparing the electrohydrodynamic stabilities of a charged drop in an electrostatic suspension and a lightning ball floating in a superposition of the gravitational field and the surface electric field. It has been assumed that the electric field strength at the surface is limited by a breakdown value. For a lightning ball radius of 15 cm, its charge is estimated as several microcoulombs. Accordingly, the density of electrostatic energy accumulated in the lightning ball is on the order of one-hundredth of a joule per square centimeter. The density of the material that constitutes the lightning ball has been estimated for the case when the electric field strength at the site of its origination is several times higher than that in fine weather. The density of the lightning ball turns out to differ from that of air by only a few percents.

  9. Structural dynamic analysis of a ball joint

    NASA Astrophysics Data System (ADS)

    Hwang, Seok-Cheol; Lee, Kwon-Hee

    2012-11-01

    Ball joint is a rotating and swiveling element that is typically installed at the interface between two parts. In an automobile, the ball joint is the component that connects the control arms to the steering knuckle. The ball joint can also be installed in linkage systems for motion control applications. This paper describes the simulation strategy for a ball joint analysis, considering manufacturing process. Its manufacturing process can be divided into plugging and spinning. Then, the interested responses is selected as the stress distribution generated between its ball and bearing. In this paper, a commercial code of NX DAFUL using an implicit integration method is introduced to calculate the response. In addition, the gap analysis is performed to investigate the fitness, focusing on the response of the displacement of a ball stud. Also, the optimum design is suggested through case studies.

  10. Adiabatic invariance of oscillons/I -balls

    NASA Astrophysics Data System (ADS)

    Kawasaki, Masahiro; Takahashi, Fuminobu; Takeda, Naoyuki

    2015-11-01

    Real scalar fields are known to fragment into spatially localized and long-lived solitons called oscillons or I -balls. We prove the adiabatic invariance of the oscillons/I -balls for a potential that allows periodic motion even in the presence of non-negligible spatial gradient energy. We show that such a potential is uniquely determined to be the quadratic one with a logarithmic correction, for which the oscillons/I -balls are absolutely stable. For slightly different forms of the scalar potential dominated by the quadratic one, the oscillons/I -balls are only quasistable, because the adiabatic charge is only approximately conserved. We check the conservation of the adiabatic charge of the I -balls in numerical simulation by slowly varying the coefficient of logarithmic corrections. This unambiguously shows that the longevity of oscillons/I -balls is due to the adiabatic invariance.

  11. Multifractal properties of ball milling dynamics

    SciTech Connect

    Budroni, M. A. Pilosu, V.; Rustici, M.; Delogu, F.

    2014-06-15

    This work focuses on the dynamics of a ball inside the reactor of a ball mill. We show that the distribution of collisions at the reactor walls exhibits multifractal properties in a wide region of the parameter space defining the geometrical characteristics of the reactor and the collision elasticity. This feature points to the presence of restricted self-organized zones of the reactor walls where the ball preferentially collides and the mechanical energy is mainly dissipated.

  12. NEW APPROACHES: The way balls bounce

    NASA Astrophysics Data System (ADS)

    Bridge, N. James

    1998-05-01

    The bounce of a ball is a good topic for investigation at either GCSE or A-level. At King's School Canterbury pupils have experimented with both squash balls and inflatable play balls, varying the drop height, pressure and temperature and measuring the effect on bounce height, contact area and contact time. Worthwhile predictions can be made from quite simple theory and the experimental results provide ample opportunities for discussion and evaluation.

  13. Actuator-valve interface optimization

    SciTech Connect

    Burchett, O.L.; Jones, R.L.

    1986-01-01

    A computer code, Actuator Valve Response (AVR), has been developed to optimize the explosive actuator-valve interface parameters so that the valve plunger velocity is at a maximum when the plunger reaches the valve tubes. The code considers three forces to act on the valve plunger before the plunger reaches the valve tubes. These are the pressure force produced by the actuator, the shear force necessary to shear the seal disks on the actuator and the valve plunger, and the friction force caused by friction between the plunger and the plunger bore. The three forces are modeled by expressions that are explicitly functions of the plunger displacement. A particular actuator-valve combination was analyzed with the computer code AVR with four different combinations of valve plunger seal disk shear strength and initial friction force. (LEW)

  14. Telescoping magnetic ball bar test gage

    DOEpatents

    Bryan, J.B.

    1982-03-15

    A telescoping magnetic ball bar test gage for determining the accuracy of machine tools, including robots, and those measuring machines having non-disengagable servo drives which cannot be clutched out. Two gage balls are held and separated from one another by a telescoping fixture which allows them relative radial motional freedom but not relative lateral motional freedom. The telescoping fixture comprises a parallel reed flexure unit and a rigid member. One gage ball is secured by a magnetic socket knuckle assembly which fixes its center with respect to the machine being tested. The other gage ball is secured by another magnetic socket knuckle assembly which is engaged or held by the machine in such manner that the center of that ball is directed to execute a prescribed trajectory, all points of which are equidistant from the center of the fixed gage ball. As the moving ball executes its trajectory, changes in the radial distance between the centers of the two balls caused by inaccuracies in the machine are determined or measured by a linear variable differential transformer (LVDT) assembly actuated by the parallel reed flexure unit. Measurements can be quickly and easily taken for multiple trajectories about several different fixed ball locations, thereby determining the accuracy of the machine.

  15. Telescoping magnetic ball bar test gage

    DOEpatents

    Bryan, J.B.

    1984-03-13

    A telescoping magnetic ball bar test gage for determining the accuracy of machine tools, including robots, and those measuring machines having non-disengageable servo drives which cannot be clutched out is disclosed. Two gage balls are held and separated from one another by a telescoping fixture which allows them relative radial motional freedom but not relative lateral motional freedom. The telescoping fixture comprises a parallel reed flexure unit and a rigid member. One gage ball is secured by a magnetic socket knuckle assembly which fixes its center with respect to the machine being tested. The other gage ball is secured by another magnetic socket knuckle assembly which is engaged or held by the machine in such manner that the center of that ball is directed to execute a prescribed trajectory, all points of which are equidistant from the center of the fixed gage ball. As the moving ball executes its trajectory, changes in the radial distance between the centers of the two balls caused by inaccuracies in the machine are determined or measured by a linear variable differential transformer (LVDT) assembly actuated by the parallel reed flexure unit. Measurements can be quickly and easily taken for multiple trajectories about several different fixed ball locations, thereby determining the accuracy of the machine. 3 figs.

  16. Telescoping magnetic ball bar test gage

    DOEpatents

    Bryan, James B.

    1984-01-01

    A telescoping magnetic ball bar test gage for determining the accuracy of machine tools, including robots, and those measuring machines having non-disengageable servo drives which cannot be clutched out. Two gage balls (10, 12) are held and separated from one another by a telescoping fixture which allows them relative radial motional freedom but not relative lateral motional freedom. The telescoping fixture comprises a parallel reed flexure unit (14) and a rigid member (16, 18, 20, 22, 24). One gage ball (10) is secured by a magnetic socket knuckle assembly (34) which fixes its center with respect to the machine being tested. The other gage ball (12) is secured by another magnetic socket knuckle assembly (38) which is engaged or held by the machine in such manner that the center of that ball (12) is directed to execute a prescribed trajectory, all points of which are equidistant from the center of the fixed gage ball (10). As the moving ball (12) executes its trajectory, changes in the radial distance between the centers of the two balls (10, 12) caused by inaccuracies in the machine are determined or measured by a linear variable differential transformer (LVDT) assembly (50, 52, 54, 56, 58, 60) actuated by the parallel reed flexure unit (14). Measurements can be quickly and easily taken for multiple trajectories about several different fixed ball (10) locations, thereby determining the accuracy of the machine.

  17. Analysis and experiment of random ball test

    NASA Astrophysics Data System (ADS)

    Lu, Liming; Wu, Fan; Hou, Xi; Zhang, Can

    2012-10-01

    Robert E.Parks from National Institute of Standards and Technology (NIST), America, first reported Random Ball Test (RBT), which is used to measure the absolute error of the reference surface of the interferometer. The basic course of this technology as followed: first, assemble the Random Ball in the confocal position of the interferometer system; then, measure the surface of the Random Ball and record the result; rotate the Random Ball to another position, meanwhile make sure that the Random Ball is in the confocal position all the time; In the new position, measure the surface of the Random Ball and record it again; repeat enough times as above, calculate the mean result of the measuring results, and this mean result is just the absolute error of the reference surface of the interferometer. Since 1998, other scholars have continued Robert E.Parks's research, and created a new type of the RBT. In this new technology, Random Ball is sustained by high pressure airflow, suspending in the air, and rotating around sphere center. This technology is called Dynamic Random Ball Test (DRBT), because the Random Ball is rotating during measurement. This article mainly reported the experiment study about the DRBT.

  18. Ceramic valve guide and seat

    SciTech Connect

    Mott, D.H.; Schmidt, H.

    1987-08-25

    For molded inclusion in a cast metal cylinder head of a internal combustion engine, an integral ceramic valve seat and valve stem guide assembly are described for operative engagement with and support of a conventional poppet-type valve with its enlarged head portion with a sealing surface thereon and an elongated cylindrical stem portion. The guide and seat consist of: valve seat forming means cast in ceramic material having an annular configuration operatively conforming to the configuration of the sealing surface of the valve and defining an annular seating surface for sealing engagement with the enlarged valve head when the valve is in a closed position; valve stem support means cast in ceramic having a generally tubular configuration with an internal bore and defining a support for reciprocation of the cylindrical stem portion of the valve as the valve moves between open and closed operative position; connecting means cast in ceramic and integral with both the valve set forming means and the valve stem supporting guide means for aligning the means so that a plane through the annular seating surface is normal to the axis of the tubular guide means and coaxially supporting the annular valve set forming means and the tubular guide portion whereas the integral valve seat forming means.

  19. Transcatheter aortic valve implantation.

    PubMed

    Nielsen, Hans Henrik Møller

    2012-12-01

    Transcatheter aortic valve implantation (TAVI) was introduced experimentally in 1989, based on a newly developed heart valve prosthesis - the stentvalve. The valve was invented by a Danish cardiologist named Henning Rud Andersen. The new valve was revolutionary. It was foldable and could be inserted via a catheter through an artery in the groin, without the need for heart lung machine. This allowed for a new valve implantation technique, much less invasive than conventional surgical aortic valve replacement (SAVR). Surgical aortic valve replacement is safe and improves symptoms along with survival. However, up to 1/3 of patients with aortic valve stenosis cannot complete the procedure due to frailty. The catheter technique was hoped to provide a new treatment option for these patients. The first human case was in 2002, but more widespread clinical use did not begin until 2006-2010. Today, in 2011, more than 40,000 valves have been implanted worldwide. Initially, because of the experimental character of the procedure, TAVI was reserved for patients who could not undergo SAVR due to high risk. The results in this group of patients were promising. The procedural safety was acceptable, and the patients experienced significant improvements in their symptoms. Three of the papers in this PhD-thesis are based on the outcome of TAVI at Skejby Hospital, in this high-risk population [I, II and IV]. Along with other international publications, they support TAVI as being superior to standard medical treatment, despite a high risk of prosthetic regurgitation. These results only apply to high-risk patients, who cannot undergo SAVR. The main purpose of this PhD study has been to investigate the quality of TAVI compared to SAVR, in order to define the indications for this new procedure. The article attached [V] describes a prospective clinical randomised controlled trial, between TAVI to SAVR in surgically amenable patients over 75 years of age with isolated aortic valve stenosis

  20. Effect of ball geometry on endurance limit in bending of drilled balls

    NASA Technical Reports Server (NTRS)

    Munson, H. E.

    1975-01-01

    Four designs of drilled (cylindrically hollow) balls were tested for resistance to bending fatigue. Bending fatigue has been demonstrated to be a limiting factor in previous evaluations of the drilled ball concept. A web reinforced drilled ball was most successful in resisting bending fatigue. Another design of through drilled design, involving a heavier wall than the standard reference ball, also showed significant improvement in resistance to bending fatigue.

  1. The Soccer-Ball Problem

    NASA Astrophysics Data System (ADS)

    Hossenfelder, Sabine

    2014-07-01

    The idea that Lorentz-symmetry in momentum space could be modified but still remain observer-independent has received quite some attention in the recent years. This modified Lorentz-symmetry, which has been argued to arise in Loop Quantum Gravity, is being used as a phenomenological model to test possibly observable effects of quantum gravity. The most pressing problem in these models is the treatment of multi-particle states, known as the 'soccer-ball problem'. This article briefly reviews the problem and the status of existing solution attempts.

  2. Two-ball Newton's cradle

    NASA Astrophysics Data System (ADS)

    Glendinning, Paul

    2011-12-01

    Newton's cradle for two balls with Hertzian interactions is considered as a hybrid system, and this makes it possible to derive return maps for the motion between collisions in an exact form despite the fact that the three-halves interaction law cannot be solved in closed form. The return maps depend on a constant whose value can only be determined numerically, but solutions can be written down explicitly in terms of this parameter, and we compare this with the results of simulations. The results are in fact independent of the details of the interaction potential.

  3. Perceval Sutureless Valve – are Sutureless Valves Here?

    PubMed Central

    Chandola, Rahul; Teoh, Kevin; Elhenawy, Abdelsalam; Christakis, George

    2015-01-01

    With the advent of transcatheter aortic valve implantation (TAVI) techniques, a renewed interest has developed in sutureless aortic valve concepts in the last decade. The main feature of sutureless aortic valve implantation is the speed of insertion, thus making implantation easier for the surgeon. As a result, cross clamp times and myocardial ischemia may be reduced. The combined procedures (CABG with AVR in particular) can be done with a short cross clamp time. Perceval valve also provides an increased effective orifice area as compared with a stented bioprosthesis. Sutureless implantation of the Perceval valve is not only associated with shorter cross-clamp and cardiopulmonary bypass times but improved clinical outcomes too. This review covers the sutureless aortic valves and their evolution, with elaborate details on Perceval S valve in particular (which is the most widely used sutureless valve around the globe). PMID:25394851

  4. 9. BUTTERFLY VALVE CONTROL DIABLO POWERHOUSE. BUTTERFLY VALVES WERE MANUFACTURED ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. BUTTERFLY VALVE CONTROL DIABLO POWERHOUSE. BUTTERFLY VALVES WERE MANUFACTURED BY THE PELTON WATER WHEEL COMPANY IN 1931, 1989. - Skagit Power Development, Diablo Powerhouse, On Skagit River, 6.1 miles upstream from Newhalem, Newhalem, Whatcom County, WA

  5. Pressure valve for needle gate valve control. June 13, 1913. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Pressure valve for needle gate valve control. June 13, 1913. Photocopy of original drawing. Drawing on file at the Salt River Project Archives. Phoenix, Arizona - Cross Cut Hydro Plant, North Side of Salt River, Tempe, Maricopa County, AZ

  6. Valve health monitoring system utilizing smart instrumentation

    NASA Astrophysics Data System (ADS)

    Jensen, Scott L.; Drouant, George J.

    2006-05-01

    The valve monitoring system is a stand alone unit with network capabilities for integration into a higher level health management system. The system is designed for aiding in failure predictions of high-geared ball valves and linearly actuated valves. It performs data tracking and archiving for identifying degraded performance. The data collection types are: cryogenic cycles, total cycles, inlet temperature, outlet temperature, body temperature, torsional strain, linear bonnet strain, preload position, total travel, and total directional changes. Events are recorded and time stamped in accordance with the IRIG B True Time. The monitoring system is designed for use in a Class 1 Division II explosive environment. The basic configuration consists of several instrumentation sensor units and a base station. The sensor units are self contained microprocessor controlled and remotely mountable in three by three by two inches. Each unit is potted in a fire retardant substance without any cavities and limited to low operating power for maintaining safe operation in a hydrogen environment. The units are temperature monitored to safeguard against operation outside temperature limitations. Each contains 902-928 MHz band digital transmitters which meet Federal Communication Commissions requirements and are limited to a 35 foot transmission radius for preserving data security. The base-station controller correlates related data from the sensor units and generates data event logs on a compact flash memory module for database uploading. The entries are also broadcast over an Ethernet network. Nitrogen purged National Electrical Manufactures Association (NEMA) Class 4 Enclosures are used to house the base-station.

  7. Sutureless aortic valve replacement

    PubMed Central

    Phan, Kevin

    2015-01-01

    The increasing incidence of aortic stenosis and greater co-morbidities and risk profiles of the contemporary patient population has driven the development of minimally invasive aortic valve surgery and percutaneous transcatheter aortic valve implantation (TAVI) techniques to reduce surgical trauma. Recent technological developments have led to an alternative minimally invasive option which avoids the placement and tying of sutures, known as “sutureless” or rapid deployment aortic valves. Potential advantages for sutureless aortic prostheses include reducing cross-clamp and cardiopulmonary bypass (CPB) duration, facilitating minimally invasive surgery and complex cardiac interventions, whilst maintaining satisfactory hemodynamic outcomes and low paravalvular leak rates. However, given its recent developments, the majority of evidence regarding sutureless aortic valve replacement (SU-AVR) is limited to observational studies and there is a paucity of adequately-powered randomized studies. Recently, the International Valvular Surgery Study Group (IVSSG) has formulated to conduct the Sutureless Projects, set to be the largest international collaborative group to investigate this technology. This keynote lecture will overview the use, the potential advantages, the caveats, and current evidence of sutureless and rapid deployment aortic valve replacement (AVR). PMID:25870807

  8. Soccer Ball Lift Coefficients via Trajectory Analysis

    ERIC Educational Resources Information Center

    Goff, John Eric; Carre, Matt J.

    2010-01-01

    We performed experiments in which a soccer ball was launched from a machine while two high-speed cameras recorded portions of the trajectory. Using the trajectory data and published drag coefficients, we extracted lift coefficients for a soccer ball. We determined lift coefficients for a wide range of spin parameters, including several spin…

  9. Using Ruby Balls As Fiducial Marks

    NASA Technical Reports Server (NTRS)

    Painter, Nance M.

    1990-01-01

    Combination of basic and advanced techniques yields new capability for inspection. In new technique, surface first inspected with fluorescent penetrant dye to reveal flaws. Ruby ball of known diameter placed near flaw having to be measured. Flaw and ball observed through magnifying video system that can "freeze" image.

  10. NCI and Leidos Play Ball | Poster

    Cancer.gov

    By Carolynne Keenan, Contributing Writer The ping of an aluminum bat off a ball or the thump of a pop-up fly ball caught in a glove are two sounds familiar to baseball fans. Slow-pitch softball sounds—like those in the August game between mixed teams of NCI and Leidos Biomedical Research (formerly SAIC-Frederick) players—are similar.

  11. Aortic valve surgery - minimally invasive

    MedlinePlus

    ... There are two main types of new valves: Mechanical, made of man-made materials, such as titanium ... Mechanical heart valves do not fail often. However, blood clots can develop on them. If a blood ...

  12. Locking apparatus for gate valves

    DOEpatents

    Fabyan, Joseph; Williams, Carl W.

    1988-01-01

    A locking apparatus for fluid operated valves having a piston connected to the valve actuator which moves in response to applied pressure within a cylinder housing having a cylinder head, a catch block is secured to the piston, and the cylinder head incorporates a catch pin. Pressure applied to the cylinder to open the valve moves the piston adjacent to the cylinder head where the catch pin automatically engages the catch block preventing futher movement of the piston or premature closure of the valve. Application of pressure to the cylinder to close the valve, retracts the catch pin, allowing the valve to close. Included are one or more selector valves, for selecting pressure application to other apparatus depending on the gate valve position, open or closed, protecting such apparatus from damage due to premature closing caused by pressure loss or operational error.

  13. Locking apparatus for gate valves

    DOEpatents

    Fabyan, J.; Williams, C.W.

    A locking apparatus for fluid operated valves having a piston connected to the valve actuator which moves in response to applied pressure within a cylinder housing having a cylinder head, a catch block is secured to the piston, and the cylinder head incorporates a catch pin. Pressure applied to the cylinder to open the valve moves the piston adjacent to the cylinder head where the catch pin automatically engages the catch block preventing further movement of the piston or premature closure of the valve. Application of pressure to the cylinder to close the valve, retracts the catch pin, allowing the valve to close. Included are one or more selector valves, for selecting pressure application to other apparatus depending on the gate valve position, open or closed, protecting such apparatus from damage due to premature closing caused by pressure loss or operational error.

  14. What Is Mitral Valve Prolapse?

    MedlinePlus

    ... may not close tightly. These flaps normally help seal or open the valve. Much of the time, ... and tricuspid valves close. They form a tight seal that prevents blood from flowing back into the ...

  15. Josephson magnetic rotary valve

    SciTech Connect

    Soloviev, I. I.; Klenov, N. V.; Bakurskiy, S. V.; Bol'ginov, V. V.; Ryazanov, V. V.; Kupriyanov, M. Yu.; Golubov, A. A.

    2014-12-15

    We propose a control element for a Josephson spin valve. It is a complex Josephson device containing ferromagnetic (F) layer in the weak-link area consisting of two regions, representing 0 and π Josephson junctions, respectively. The valve's state is defined by mutual orientations of the F-layer magnetization vector and boundary line between 0 and π sections of the device. We consider possible implementation of the control element by introduction of a thin normal metal layer in a part of the device area. By means of theoretical simulations, we study properties of the valve's structure as well as its operation, revealing such advantages as simplicity of control, high characteristic frequency, and good legibility of the basic states.

  16. Valve-spring Surge

    NASA Technical Reports Server (NTRS)

    Marti, Willy

    1937-01-01

    Test equipment is described that includes a system of three quartz indicators whereby three different pressures could be synchronized and simultaneously recorded on a single oscillogram. This equipment was used to test the reliction of waves at ends of valve spring, the dynamical stress of the valve spring for a single lift of the valve, and measurement of the curve of the cam tested. Other tests included simultaneous recording of the stress at both ends of the spring, spring oscillation during a single lift as a function of speed, computation of amplitude of oscillation for a single lift by harmonic analysis, effect of cam profile, the setting up of resonance, and forced spring oscillation with damping.

  17. Well valve control system

    SciTech Connect

    Schwendemann, K.L.; McCracken, O.W.; Mondon, C.G.; Wortham, L.C.

    1987-01-13

    A system is described for controlling well testing through an upper and lower test string with a subsea test tree connected therebetween and latch means to release the upper test string from the subsea test tree comprising: a. first and second selectively programmable microprocessor means; b. means for storing system operating limits in each microprocessor means; c. means for changing the operating limits in response to changes in well conditions; d. means for communicating operating fluid pressure to the subsurface test tree and the latch means; e. solenoid pilot valves controlling the flow of the operating fluid pressure to the subsea test tree and the latch means; f. the first microprocessor means located at a central control console; g. the second microprocessor means located near the solenoid valves; h. means for transmitting signals between the first and second microprocessor means and validating the accuracy of the signals; and i. electronic circuits to control operation of the solenoid valves in response to validated signals.

  18. Mitral valve prolapse.

    PubMed

    Guy, T Sloane; Hill, Arthur C

    2012-01-01

    Mitral valve prolapse is defined as abnormal bulging of the mitral valve leaflets into the left atrium during ventricular systole. Mitral valve prolapse is a common condition that is a risk factor for mitral regurgitation, congestive heart failure, arrhythmia, and endocarditis. Myxomatous degeneration is the most common cause of mitral prolapse in the United States and Europe, and progression of myxomatous mitral prolapse is the most common cause of mitral regurgitation that requires surgical treatment. Myxomatous degeneration appears to have genetic etiology. The genetics of myxomatous degeneration is complex and not fully worked out; it appears to be heterogeneous with multi-gene, multi-chromosomal autosomal dominance with incomplete penetrance. The molecular disorder of myxomatous degeneration appears to consist of a connective tissue disorder with altered extracellular matrix status and involves the action of matrix metalloproteinase, cysteine endoproteases, and tenomodulin. Treatment of mitral prolapse with regurgitation is complex, and the technological advances that are currently in development will be challenging and controversial.

  19. Hydrogen gas relief valve

    DOEpatents

    Whittlesey, Curtis C.

    1985-01-01

    An improved battery stack design for an electrochemical system having at least one cell from which a gas is generated and an electrolyte in communication with the cell is described. The improved battery stack design features means for defining a substantially closed compartment for containing the battery cells and at least a portion of the electrolyte for the system, and means in association with the compartment means for selectively venting gas from the interior of the compartment means in response to the level of the electrolyte within the compartment means. The venting means includes a relief valve having a float member which is actuated in response to the level of the electrolyte within the compartment means. This float member is adapted to close the relief valve when the level of the electrolyte is above a predetermined level and open the relief valve when the level of electrolyte is below this predetermined level.

  20. Variable Valve Actuation

    SciTech Connect

    Jeffrey Gutterman; A. J. Lasley

    2008-08-31

    Many approaches exist to enable advanced mode, low temperature combustion systems for diesel engines - such as premixed charge compression ignition (PCCI), Homogeneous Charge Compression Ignition (HCCI) or other HCCI-like combustion modes. The fuel properties and the quantity, distribution and temperature profile of air, fuel and residual fraction in the cylinder can have a marked effect on the heat release rate and combustion phasing. Figure 1 shows that a systems approach is required for HCCI-like combustion. While the exact requirements remain unclear (and will vary depending on fuel, engine size and application), some form of substantially variable valve actuation is a likely element in such a system. Variable valve actuation, for both intake and exhaust valve events, is a potent tool for controlling the parameters that are critical to HCCI-like combustion and expanding its operational range. Additionally, VVA can be used to optimize the combustion process as well as exhaust temperatures and impact the after treatment system requirements and its associated cost. Delphi Corporation has major manufacturing and product development and applied R&D expertise in the valve train area. Historical R&D experience includes the development of fully variable electro-hydraulic valve train on research engines as well as several generations of mechanical VVA for gasoline systems. This experience has enabled us to evaluate various implementations and determine the strengths and weaknesses of each. While a fully variable electro-hydraulic valve train system might be the 'ideal' solution technically for maximum flexibility in the timing and control of the valve events, its complexity, associated costs, and high power consumption make its implementation on low cost high volume applications unlikely. Conversely, a simple mechanical system might be a low cost solution but not deliver the flexibility required for HCCI operation. After modeling more than 200 variations of the

  1. Bending stresses in spherically hollow ball bearing and fatigue experiments

    NASA Technical Reports Server (NTRS)

    Nypan, L. J.; Coe, H. H.; Parker, R. J.

    1975-01-01

    Spherically hollow balls of 21.7, 50.0, and 56.5 percent mass reduction were operated in ball bearings and in a five-ball fatigue tester with differing outcomes. Available theoretical and experimental treatments of stresses in spherically hollow balls are reviewed and compared. Bending stresses are estimated for these spherically hollow balls to better understand the differences in ball bearing and fatigue test experience.

  2. Bending stresses in spherically hollow ball bearing and fatigue experiments

    NASA Technical Reports Server (NTRS)

    Nypan, L. J.; Coe, H. H.; Parker, R. J.

    1975-01-01

    Spherically hollow balls of 21.7, 50.0 and 56.5 per cent mass reduction have been operated in ball bearings and in a 5-ball fatigue tester with differing outcomes. Available theoretical and experimental treatments of stresses in spherically hollow balls are reviewed and compared. Bending stresses are estimated for these spherically hollow balls to better understand the differences in ball bearing and fatigue test experience.

  3. New subsurface safety valve designs for slimhole/monobore completions

    SciTech Connect

    Vinzant, M.; Smith, R.

    1995-12-31

    Over the past decade, operators have been faced with an ever-increasing demand to reduce operational costs. One approach to effecting this reduction has been to maximize production tubing bores while reducing corresponding casing sizes. These new concepts have required many completion configurations and related equipment to undergo extensive change. An excellent example of how new requirements for design enhancement for one technology can impact the design of related equipment is shown in a review of the slimhole/monobore completion technique. This paper will discuss enhancements to subsurface safety valve equipment that have been required by the need to support the new requirements of slimhole monobore technology. The paper will present an overview of: the evolution of the flapper design; the constraints various flapper designs place on OD/ID ratios of the safety valve for slimhole monobore completions; and the extensive testing that has been performed to verify performance capability. Comparison of OD/ID capabilities will be made between conventional ``flat plate`` flappers, curved flappers, and ball valve designs. Finally, the design of a proven flapper that uses a uniquely contoured configuration to (1) optimize OD/ID ratio, (2) provide enhanced metal-to-metal sealing capabilities, and (3) address the problems faced with other safety valve design options will be presented.

  4. Automatic monitoring of valve status

    SciTech Connect

    Prinz, F.B.; Chern, J.H.

    1989-06-01

    Authors propose establishing the relationship between valve leaking and thermal gradient to allow detection of valve leakage by observing the piping system`s temperature profile and using an expert system to infer the valve condition. They describe their work toward this and their January 1988 report thereon. The authors also suggest designing modem power plants to accommodate a remotely controlled or autonomous vehicle which would carry a device for thermal-gradient leak detection to examine valves in situ.

  5. Self-regulating valve

    DOEpatents

    Humphreys, D.A.

    1982-07-20

    A variable, self-regulating valve having a hydraulic loss coefficient proportional to a positive exponential power of the flow rate. The device includes two objects in a flow channel and structure which assures that the distance between the two objects is an increasing function of the flow rate. The range of spacing between the objects is such that the hydraulic resistance of the valve is an increasing function of the distance between the two objects so that the desired hydraulic loss coefficient as a function of flow rate is obtained without variation in the flow area.

  6. Tide gate valve

    SciTech Connect

    Raftis, S. G.

    1985-01-08

    A tide gate check valve in which at least three converging sides are provided at a tapered region of a flexible sleeve, so that on reverse back pressure build-up of fluid, reverse fluid flow is prevented, while the valve sleeve does not invert or collapse. The present configuration features embedded reinforcing elements for resisting inversion or collapsing when the back pressure builds up. This feature is especially important for large-sized conduits of 36'' or 72'' diameter, or even larger, such as are common in storm sewer applications.

  7. Lightweight Valve Closes Duct Quickly

    NASA Technical Reports Server (NTRS)

    Fournier, Walter L.; Burgy, N. Frank

    1991-01-01

    Expanding balloon serves as lightweight emergency valve to close wide duct. Uninflated balloon stored in housing of duct. Pad resting on burst diaphragm protects balloon from hot gases in duct. Once control system triggers valve, balloon inflates rapidly to block duct. Weighs much less than does conventional butterfly, hot-gas, or poppet valve capable of closing duct of equal diameter.

  8. Valve stem and packing assembly

    DOEpatents

    Wordin, John J.

    1991-01-01

    A valve stem and packing assembly is provided in which a rotatable valve stem includes a first tractrix surface for sliding contact with a stem packing and also includes a second tractrix surface for sliding contact with a bonnet. Force is applied by means of a spring, gland flange, and gland on the stem packing so the stem packing seals to the valve stem and bonnet. This configuration serves to create and maintain a reliable seal between the stem packing and the valve stem. The bonnet includes a second complementary tractrix surface for contacting the second sliding tractrix surface, the combination serving as a journal bearing for the entire valve stem and packing assembly. The journal bearing so configured is known as a Schiele's pivot. The Schiele's pivot also serves to maintain proper alignment of the valve stem with respect to the bonnet. Vertical wear between the surfaces of the Schiele's pivot is uniform at all points of contact between the second sliding tractrix surface and the second complementary tractrix surface of a bonnet. The valve stem is connected to a valve plug by means of a slip joint. The valve is opened and closed by rotating the valve stem. The slip joint compensates for wear on the Schiele's pivot and on the valve plug. A ledge is provided on the valve bonnet for the retaining nut to bear against. The ledge prevents overtightening of the retaining nut and the resulting excessive friction between stem and stem packing.

  9. Valve stem and packing assembly

    DOEpatents

    Wordin, J.J.

    1991-09-03

    A valve stem and packing assembly is provided in which a rotatable valve stem includes a first tractrix surface for sliding contact with a stem packing and also includes a second tractrix surface for sliding contact with a bonnet. Force is applied by means of a spring, gland flange, and gland on the stem packing so the stem packing seals to the valve stem and bonnet. This configuration serves to create and maintain a reliable seal between the stem packing and the valve stem. The bonnet includes a second complementary tractrix surface for contacting the second sliding tractrix surface, the combination serving as a journal bearing for the entire valve stem and packing assembly. The journal bearing so configured is known as a Schiele's pivot. The Schiele's pivot also serves to maintain proper alignment of the valve stem with respect to the bonnet. Vertical wear between the surfaces of the Schiele's pivot is uniform at all points of contact between the second sliding tractrix surface and the second complementary tractrix surface of a bonnet. The valve stem is connected to a valve plug by means of a slip joint. The valve is opened and closed by rotating the valve stem. The slip joint compensates for wear on the Schiele's pivot and on the valve plug. A ledge is provided on the valve bonnet for the retaining nut to bear against. The ledge prevents over tightening of the retaining nut and the resulting excessive friction between stem and stem packing. 2 figures.

  10. Ready for the Cosmic Ball

    NASA Technical Reports Server (NTRS)

    2006-01-01

    Something appears to be peering through a shiny red mask, in this new false-colored image from NASA's Spitzer Space Telescope. The mysterious blue eyes are actually starlight from the cores of two merging galaxies, called NGC 2207 and IC 2163. The mask is the galaxies' dusty spiral arms.

    NGC 2207 and IC 2163 recently met and began a sort of gravitational tango about 40 million years ago. The two galaxies are tugging at each other, stimulating new stars to form. Eventually, this cosmic ball will come to an end, when the galaxies meld into one. The dancing duo is located 140 million light-years away in the Canis Major constellation.

    The Spitzer image reveals that the galactic mask is adorned with strings of pearl-like beads. These dusty clusters of newborn stars, called 'beads on a string' by astronomers, appear as white balls throughout the arms of both galaxies. They were formed when the galaxies first interacted, forcing dust and gas to clump together into colonies of stars.

    This type of beading has been seen before in other galaxies, but it took Spitzer's infrared eyes to identify them in NGC 2207 and IC 2163. Spitzer was able to see the beads because the stars inside heat up surrounding dust, which then radiates with infrared light.

    The biggest bead lighting up the left side of the mask is also the densest. In fact, some of its central stars might have merged to form a black hole. (Now, that would be quite the Mardi Gras mask!)

    This picture, taken by Spitzer's infrared array camera, is a four-channel composite. It shows light with wavelengths of 3.6 microns (blue); 4.5 microns (green); and 5.8 and 8.0 microns (red). The contribution from starlight (measured at 3.6 microns) has been subtracted from the 5.8- and 8-micron channels to enhance the visibility of the dust features.

  11. Improved Merge Valve

    NASA Technical Reports Server (NTRS)

    George-Falvy, Dez

    1992-01-01

    Circumferential design combines compactness and efficiency. In remotely controlled valve, flow in tributary duct along circumference of primary duct merged with flow in primary duct. Flow in tributary duct regulated by variable throat nuzzle driven by worm gear. Design leak-proof, and most components easily fabricated on lathe.

  12. Valve for cryogenic service

    DOEpatents

    Worwetz, H.A.

    1975-09-02

    This patent relates to a valve for use with a liquefied gas at cryogenic temperatures in which a pair of joined knife edges are bellows controlled to contact an indium alloy seat in an annular slot when flow is to be stopped. The sealing alloy may be renewed by heating in situ. (auth)

  13. Thermostatic Radiator Valve Evaluation

    SciTech Connect

    Dentz, Jordan; Ansanelli, Eric

    2015-01-01

    A large stock of multifamily buildings in the Northeast and Midwest are heated by steam distribution systems. Losses from these systems are typically high and a significant number of apartments are overheated much of the time. Thermostatically controlled radiator valves (TRVs) are one potential strategy to combat this problem, but have not been widely accepted by the residential retrofit market.

  14. Vent Relief Valve Test

    NASA Technical Reports Server (NTRS)

    2008-01-01

    Shown is the disassembly, examination, refurbishment and testing of the LH2 ( liquid hydrogen) and LOX (liquid oxygen) vent and relief valves for the S-IVB-211 engine stage in support of the Constellation/Ares project. This image is extracted from high definition video and is the highest resolution available.

  15. Quadricuspid aortic valves.

    PubMed

    Timperley, Jonathan; Milner, Robert; Marshall, Andrew J; Gilbert, Timothy J

    2002-12-01

    Quadricuspid aortic valves (QAV) are a rare but well recognized cause of significant aortic regurgitation. The first case was found reported in 1862. Since then there have been 110 reported cases of QAV and we report 4 more. Previously, these were diagnosed at the time of surgery or postmortem examination. With advances in echocardiography, including harmonic imaging, and also the advent of transesophageal echocardiography, more cases are being diagnosed prior to surgery. We describe four more cases, three diagnosed preoperatively and one at the time of surgery, and then review the previously reported cases. Of the 114 cases reported, 46 had the aortic valve replaced, most commonly in the 5th and 6th decade of life. Hurwitz and Roberts classified quadricuspid valves according to the size of the leaflets. It has previously been believed that QAVs with four equal sized leaflets were less likely to develop significant aortic regurgitation; however, on review of the available cases, this would not appear to be the case. The preoperative diagnosis of QAVs is important as they can be associated with abnormally placed coronary ostium. Of the 114 cases reported, there are 10 reports of abnormally placed ostia. There has been at least one reported case of death occurring because of obstruction of an abnormally placed right coronary ostium by a prosthetic aortic valve.

  16. Eustachian valve endocarditis.

    PubMed Central

    Vilacosta, I; San Roman, J A; Roca, V

    1990-01-01

    M mode and cross sectional echocardiography showed a highly mobile globular pedunculated mass(3.0 cm long with a maximum diameter of i.5 cm) attached to the eustachian valve in a heroin addict with staphylococcal endocarditis. Images Figure 1 Figure 2 PMID:2245118

  17. Valve for gas centrifuges

    DOEpatents

    Hahs, C.A.; Rurbage, C.H.

    1982-03-17

    The invention is pneumatically operated valve assembly for simulatenously (1) closing gas-transfer lines connected to a gas centrifuge or the like and (2) establishing a recycle path between two on the lines so closed. The value assembly is especially designed to be compact, fast-acting, reliable, and comparatively inexpensive. It provides large reductions in capital costs for gas-centrifuge cascades.

  18. TUBE SHEARING VALVE

    DOEpatents

    Wilner, L.B.

    1960-05-24

    Explosive operated valves can be used to join two or more containers in fluid flow relationship, one such container being a sealed reservoir. The valve is most simply disposed by mounting it on the reservoir so thst a tube extends from the interior of the reservoir through the valve body, terminating at the bottom of the bore in a closed end; other containers may be similarly connected or may be open connected, as desired. The piston of the valve has a cutting edge at its lower end which shears off the closed tube ends and a recess above the cutting edge to provide a flow channel. Intermixing of the fluid being transferred with the explosion gases is prevented by a copper ring at the top of the piston which is force fitted into the bore at the beginning of the stroke. Although designed to avoid backing up of the piston at pressures up to 10,000 psi in the transferred fluid, proper operation is independent of piston position, once the tube ends were sheared.

  19. Dolphin underwater bait-balling behaviors in relation to group and prey ball sizes.

    PubMed

    Vaughn-Hirshorn, Robin L; Muzi, Elisa; Richardson, Jessica L; Fox, Gabriella J; Hansen, Lauren N; Salley, Alyce M; Dudzinski, Kathleen M; Würsig, Bernd

    2013-09-01

    We characterized dusky dolphin (Lagenorhynchus obscurus) feeding behaviors recorded on underwater video, and related behaviors to variation in prey ball sizes, dolphin group sizes, and study site (Argentina versus New Zealand, NZ). Herding behaviors most often involved dolphins swimming around the side or under prey balls, but dolphins in Argentina more often swam under prey balls (48% of passes) than did dolphins in NZ (34% of passes). This result may have been due to differences in group sizes between sites, since groups are larger in Argentina. Additionally, in NZ, group size was positively correlated with proportion of passes that occurred under prey balls (p<0.001). Prey-capture attempts most often involved capturing fish from the side of prey balls, but dolphins in Argentina more often swam through prey balls (8% of attempts) than did dolphins in NZ (4% of attempts). This result may have been due to differences in prey ball sizes between sites, since dolphins fed on larger prey balls in Argentina (>74m(2)) than in NZ (maximum 33m(2)). Additionally, in NZ, dolphins were more likely to swim through prey balls to capture fish when they fed on larger prey balls (p=0.025).

  20. Numerical simulation of ball-racket impact

    NASA Astrophysics Data System (ADS)

    Yu, Yingpang

    The collision of a ball with a tennis racket is usually modeled in terms of rigid body dynamics or an elastic system involving only a few springs. In this paper, we study the impact between a tennis ball and racket, by modeling the tennis ball in two different yaws. One method models the tennis ball as a Hertz elastic body and the other one models the ball by a more accurate finite element analysis. In the first model, we assume that the elastic properties of the ball obeys Hertz's law. In the finite element model, we consider the tennis ball as a shell witch is a elastic system constructed out of many isotropic small linear flat, elements, witch have both elastic and damping properties. The damping in each way is approximated as viscous term. In both methods, we study the static condition of deformation against a rigid surface before applying these models to dynamical processes. We compare these two methods and eventually determine how the racket parameters effect the performance of the racket, using numerical simulations. Comparison with experiment are show to confirm the general conclusion of the model.

  1. Viscoelastic modelling of tennis ball properties

    NASA Astrophysics Data System (ADS)

    Sissler, L.; Jones, R.; Leaney, P. G.; Harland, A.

    2010-06-01

    An explicit finite element (FE) tennis ball model which illustrates the effects of the viscoelastic materials of a tennis ball on ball deformation and bounce during normal impacts is presented. A tennis ball is composed of a rubber core and a fabric cover comprised of a wool-nylon mix which exhibit non-linear strain rate properties during high velocity impacts. The rubber core model was developed and validated using low strain rate tensile tests on rubber samples as well as high velocity normal impacts of pressurised cores at velocities ranging from 15 m/s to 50 m/s. The impacts were recorded using a high speed video (HSV) camera to determine deformation, impact time and coefficient of restitution (COR). The material properties of the core model were tuned to match the HSV results. A two component anisotropic fabric model was created which included artificial Rayleigh damping to account for hysteresis effects, and the core model 'tuning' process was used to refine the cloth layer. The ball model's parameters were in good agreement with experimental data at all velocities for both cores and complete balls, and a time sequenced comparison of HSV ball motion and FE model confirmed the validity of the model.

  2. Cricket Ball Aerodynamics: Myth Versus Science

    NASA Technical Reports Server (NTRS)

    Mehta, Rabindra D.; Koga, Demmis J. (Technical Monitor)

    2000-01-01

    Aerodynamics plays a prominent role in the flight of a cricket ball released by a bowler. The main interest is in the fact that the ball can follow a curved flight path that is not always under the control of the bowler. ne basic aerodynamic principles responsible for the nonlinear flight or "swing" of a cricket ball were identified several years ago and many papers have been published on the subject. In the last 20 years or so, several experimental investigations have been conducted on cricket ball swing, which revealed the amount of attainable swing, and the parameters that affect it. A general overview of these findings is presented with emphasis on the concept of late swing and the effects of meteorological conditions on swing. In addition, the relatively new concept of "reverse" swing, how it can be achieved in practice and the role in it of ball "tampering", are discussed in detail. A discussion of the "white" cricket ball used in last year's World Cup, which supposedly possesses different swing properties compared to a conventional red ball, is also presented.

  3. Multi-port valve assembly

    DOEpatents

    Guggenheim, S. Frederic

    1986-01-01

    A multi-port fluid valve apparatus is used to control the flow of fluids through a plurality of valves and includes a web, which preferably is a stainless steel endless belt. The belt has an aperture therethrough and is progressed, under motor drive and control, so that its aperture is moved from one valve mechanism to another. Each of the valve mechanisms comprises a pair of valve blocks which are held in fluid-tight relationship against the belt. Each valve block consists of a block having a bore through which the fluid flows, a first seal surrounding the bore and a second seal surrounding the first seal, with the distance between the first and second seals being greater than the size of the belt aperture. In order to open a valve, the motor progresses the belt aperture to where it is aligned with the two bores of a pair of valve blocks, such alignment permitting a flow of the fluid through the valve. The valve is closed by movement of the belt aperture and its replacement, within the pair of valve blocks, by a solid portion of the belt.

  4. Designing Hollow Nano Gold Golf Balls

    PubMed Central

    2015-01-01

    Hollow/porous nanoparticles, including nanocarriers, nanoshells, and mesoporous materials have applications in catalysis, photonics, biosensing, and delivery of theranostic agents. Using a hierarchical template synthesis scheme, we have synthesized a nanocarrier mimicking a golf ball, consisting of (i) solid silica core with a pitted gold surface and (ii) a hollow/porous gold shell without silica. The template consisted of 100 nm polystyrene beads attached to a larger silica core. Selective gold plating of the core followed by removal of the polystyrene beads produced a golf ball-like nanostructure with 100 nm pits. Dissolution of the silica core produced a hollow/porous golf ball-like nanostructure. PMID:24937196

  5. Horizontal stability of a bouncing ball

    NASA Astrophysics Data System (ADS)

    McBennett, Brendan G.; Harris, Daniel M.

    2016-09-01

    We present an investigation of a partially elastic ball bouncing on a vertically vibrated concave parabolic surface in two dimensions. In particular, we demonstrate that simple vertical motion, wherein the ball bounces periodically at the parabola's vertex, is unstable to horizontal perturbations when the parabolic coefficient defining the surface shape exceeds a critical value. The result is a new periodic solution where the ball bounces laterally over the vertex. As the parabola is further steepened, this new solution also becomes unstable which gives rise to other complex periodic and chaotic bouncing states, all characterized by persistent lateral motion.

  6. Micro-valve pump light valve display

    DOEpatents

    Yeechun Lee.

    1993-01-19

    A flat panel display incorporates a plurality of micro-pump light valves (MLV's) to form pixels for recreating an image. Each MLV consists of a dielectric drop sandwiched between substrates, at least one of which is transparent, a holding electrode for maintaining the drop outside a viewing area, and a switching electrode from accelerating the drop from a location within the holding electrode to a location within the viewing area. The sustrates may further define non-wetting surface areas to create potential energy barriers to assist in controlling movement of the drop. The forces acting on the drop are quadratic in nature to provide a nonlinear response for increased image contrast. A crossed electrode structure can be used to activate the pixels whereby a large flat panel display is formed without active driver components at each pixel.

  7. Micro-valve pump light valve display

    DOEpatents

    Lee, Yee-Chun

    1993-01-01

    A flat panel display incorporates a plurality of micro-pump light valves (MLV's) to form pixels for recreating an image. Each MLV consists of a dielectric drop sandwiched between substrates, at least one of which is transparent, a holding electrode for maintaining the drop outside a viewing area, and a switching electrode from accelerating the drop from a location within the holding electrode to a location within the viewing area. The sustrates may further define non-wetting surface areas to create potential energy barriers to assist in controlling movement of the drop. The forces acting on the drop are quadratic in nature to provide a nonlinear response for increased image contrast. A crossed electrode structure can be used to activate the pixels whereby a large flat panel display is formed without active driver components at each pixel.

  8. Valve-in-valve transcatheter aortic valve implantation overcoming hostile anatomy: Evolut R for the treatment of Mitroflow bioprosthesis dysfunction.

    PubMed

    Ruparelia, Neil; Colombo, Antonio; Latib, Azeem

    2016-10-01

    Redo surgery is regarded as the first-line treatment option for patients presenting with prosthetic valve degeneration. However, many patients have concomitant co-morbidities and this option is associated with significant risk. Transcatheter valve-in-valve implantation is an alternative strategy depending on the bioprosthetic valve that is being treated. The Sorin Mitroflow bioprosthetic aortic valve has been regarded as a contraindication to valve-in-valve treatment due to the high risk of coronary obstruction. We here present the case of a patient with small peripheral vasculature who underwent successful transfemoral valve-in-valve implantation and subsequently discuss the challenges and technical aspects that require consideration.

  9. Production of Ball-Lightning-Like Luminous Balls by Electrical Discharges in Silicon

    NASA Astrophysics Data System (ADS)

    Paiva, Gerson Silva; Pavão, Antonio Carlos; Alpes de Vasconcelos, Elder; Mendes, Odim, Jr.; Felisberto da Silva, Eronides, Jr.

    2007-01-01

    We performed electric arc discharges in pure Si to generate luminous balls with lifetime in the order of seconds and several properties usually reported for natural ball lightning. This simple experiment does not rely on energy sources and excitation mechanisms that are improbable in the natural phenomenon and clearly demonstrates the role of vaporization and oxidation of Si, as proposed by the Abrahamson-Dinniss theory for ball-lightning formation.

  10. Production of ball-lightning-like luminous balls by electrical discharges in silicon.

    PubMed

    Paiva, Gerson Silva; Pavão, Antonio Carlos; Alpes de Vasconcelos, Elder; Mendes, Odim; da Silva, Eronides Felisberto

    2007-01-26

    We performed electric arc discharges in pure Si to generate luminous balls with lifetime in the order of seconds and several properties usually reported for natural ball lightning. This simple experiment does not rely on energy sources and excitation mechanisms that are improbable in the natural phenomenon and clearly demonstrates the role of vaporization and oxidation of Si, as proposed by the Abrahamson-Dinniss theory for ball-lightning formation.

  11. Production of ball-lightning-like luminous balls by electrical discharges in silicon.

    PubMed

    Paiva, Gerson Silva; Pavão, Antonio Carlos; Alpes de Vasconcelos, Elder; Mendes, Odim; da Silva, Eronides Felisberto

    2007-01-26

    We performed electric arc discharges in pure Si to generate luminous balls with lifetime in the order of seconds and several properties usually reported for natural ball lightning. This simple experiment does not rely on energy sources and excitation mechanisms that are improbable in the natural phenomenon and clearly demonstrates the role of vaporization and oxidation of Si, as proposed by the Abrahamson-Dinniss theory for ball-lightning formation. PMID:17358820

  12. Flexible timing of eye movements when catching a ball.

    PubMed

    López-Moliner, Joan; Brenner, Eli

    2016-01-01

    In ball games, one cannot direct ones gaze at the ball all the time because one must also judge other aspects of the game, such as other players' positions. We wanted to know whether there are times at which obtaining information about the ball is particularly beneficial for catching it. We recently found that people could catch successfully if they saw any part of the ball's flight except the very end, when sensory-motor delays make it impossible to use new information. Nevertheless, there may be a preferred time to see the ball. We examined when six catchers would choose to look at the ball if they had to both catch the ball and find out what to do with it while the ball was approaching. A catcher and a thrower continuously threw a ball back and forth. We recorded their hand movements, the catcher's eye movements, and the ball's path. While the ball was approaching the catcher, information was provided on a screen about how the catcher should throw the ball back to the thrower (its peak height). This information disappeared just before the catcher caught the ball. Initially there was a slight tendency to look at the ball before looking at the screen but, later, most catchers tended to look at the screen before looking at the ball. Rather than being particularly eager to see the ball at a certain time, people appear to adjust their eye movements to the combined requirements of the task.

  13. Flexible timing of eye movements when catching a ball.

    PubMed

    López-Moliner, Joan; Brenner, Eli

    2016-01-01

    In ball games, one cannot direct ones gaze at the ball all the time because one must also judge other aspects of the game, such as other players' positions. We wanted to know whether there are times at which obtaining information about the ball is particularly beneficial for catching it. We recently found that people could catch successfully if they saw any part of the ball's flight except the very end, when sensory-motor delays make it impossible to use new information. Nevertheless, there may be a preferred time to see the ball. We examined when six catchers would choose to look at the ball if they had to both catch the ball and find out what to do with it while the ball was approaching. A catcher and a thrower continuously threw a ball back and forth. We recorded their hand movements, the catcher's eye movements, and the ball's path. While the ball was approaching the catcher, information was provided on a screen about how the catcher should throw the ball back to the thrower (its peak height). This information disappeared just before the catcher caught the ball. Initially there was a slight tendency to look at the ball before looking at the screen but, later, most catchers tended to look at the screen before looking at the ball. Rather than being particularly eager to see the ball at a certain time, people appear to adjust their eye movements to the combined requirements of the task. PMID:26982371

  14. Laryngeal Fracture Caused by a Lacrosse Ball.

    PubMed

    Trinidade, Aaron; Shakeel, Muhammad; Stickle, Brian; Ah-See, Kim W

    2015-11-01

    Neck injuries in lacrosse are rare and mostly involve the musculoskeletal system. The lacrosse ball is a solid rubber ball of approximately 20 cm in diameter and the fastest shot recorded in professional lacrosse is over 100 mph. Despite wearing full protection, the neck remains prone to blunt trauma by this ball. A 23-year man sustained a direct blow to his left neck by a lacrosse ball during play, resulting in immediate aphonia and stridor. CT scan confirmed a left thyroid lamina fracture. The patient was treated conservatively and his airway was monitored for 24 hours. He made a full recovery. It is important that lacrosse players should be aware of this potential injury and appropriate precautions should be taken to avoid this trauma.

  15. Laryngeal Fracture Caused by a Lacrosse Ball.

    PubMed

    Trinidade, Aaron; Shakeel, Muhammad; Stickle, Brian; Ah-See, Kim W

    2015-11-01

    Neck injuries in lacrosse are rare and mostly involve the musculoskeletal system. The lacrosse ball is a solid rubber ball of approximately 20 cm in diameter and the fastest shot recorded in professional lacrosse is over 100 mph. Despite wearing full protection, the neck remains prone to blunt trauma by this ball. A 23-year man sustained a direct blow to his left neck by a lacrosse ball during play, resulting in immediate aphonia and stridor. CT scan confirmed a left thyroid lamina fracture. The patient was treated conservatively and his airway was monitored for 24 hours. He made a full recovery. It is important that lacrosse players should be aware of this potential injury and appropriate precautions should be taken to avoid this trauma. PMID:26577976

  16. Reexamination of Ball-Race Conformity Effects on Ball Bearing Life

    NASA Technical Reports Server (NTRS)

    Zaretsky, Erwin V.; Poplawski, Joseph V.; Root, Lawrence E.

    2007-01-01

    The analysis in this report considers the life of the ball set as well as the respective lives of the races to reassess the effect of ball-race conformity on ball bearing life. The related changes in ball bearing life are incorporated in life factors that can be used to modify the bearing predicted life using the Lundberg-Palmgren equations and the ANSI/ABMA and ISO Standards. Two simple algebraic relationships were established to calculate life factors LF(sub c) to determine the effect of inner- and outer-race conformity combinations on bearing L(sub 10) life for deepgroove and angular-contact ball bearings, respectively. Depending on the bearing type and series as well as conformity combinations, the calculated life for deep-groove ball bearings can be over 40 percent less than that calculated by the Lundberg-Palmgren equations. For angular-contact ball bearings, the life can vary between +16 and -39 percent from that calculated by the Lundberg-Palmgren equations. Comparing the two ball bearing types, the life factors LF(sub c) for the deep-groove bearings can be as much as 40 percent lower than that for angular-contact ball bearings.

  17. Fast acting multiple element valve

    DOEpatents

    Yang, Jefferson Y. S.; Wada, James M.

    1991-01-01

    A plurality of slide valve elements having plural axial-spaced annular parts and an internal slide are inserted into a bulkhead in a fluid conduit from a downstream side of the bulkhead, locked in place by a bayonet coupling and set screw, and project through the bulkhead into the upstream conduit. Pneumatic lines connecting the slide valve element actuator to pilot valves are brought out the throat of the valve element to the downstream side. Pilot valves are radially spaced around the exterior of the valve to permit the pneumatic lines to be made identical, thereby to minimize adverse timing tolerances in operation due to pressure variations. Ring manifolds surround the valve adjacent respective pilot valve arrangements to further reduce adverse timing tolerances due to pressure variations, the manifolds being directly connected to the respective pilot valves. Position sensors are provided the valve element slides to signal the precise time at which a slide reaches or passes through a particular point in its stroke to initiate a calibrated timing function.

  18. Bouncing ball problem: numerical behavior characterization

    NASA Astrophysics Data System (ADS)

    Macau, E. E. N.; Carneiro, M. V.; Barroso, J. J.

    2010-09-01

    This paper gives an overview of the simple yet fundamental bouncing ball problem, which consists of a ball bouncing vertically on a sinusoidally vibrating table under the action of gravity. The dynamics is modeled on the basis of a discrete map of difference equations, which numerically solved fully reveals a rich variety of nonlinear behaviors, encompassing irregular non-periodic orbits, subharmonic and chaotic motions, chattering mechanisms, and also unbounded non-periodic orbits.

  19. Gravitational waves from Q-ball formation

    SciTech Connect

    Chiba, Takeshi; Kamada, Kohei; Yamaguchi, Masahide

    2010-04-15

    We study the detectability of the gravitational waves (GWs) from the Q-ball formation associated with the Affleck-Dine (AD) mechanism, taking into account both the dilution effects due to Q-ball domination and to finite temperature. The AD mechanism predicts the formation of nontopological solitons, Q-balls, from which GWs are generated. Q-balls with large conserved charge Q can produce a large amount of GWs. On the other hand, the decay rate of such Q-balls is so small that they may dominate the energy density of the Universe, which implies that GWs are significantly diluted and that their frequencies are redshifted during the Q-ball dominated era. Thus, the detectability of the GWs associated with the formation of Q-balls is determined by these two competing effects. We find that there is a finite but small parameter region where such GWs may be detected by future detectors such as DECIGO or BBO, only in the case when the thermal logarithmic potential dominates the potential of the AD field. Otherwise GWs from Q-balls would not be detectable even by these futuristic detectors: {Omega}{sub GW}{sup 0}<10{sup -21}. Unfortunately, for such parameter region the present baryon asymmetry of the Universe can hardly be explained unless one fine-tunes A-terms in the potential. However the detection of such a GW background may give us an information about the early Universe, for example, it may suggest that the flat directions with B-L=0 are favored.

  20. Fractal aggregates in tennis ball systems

    NASA Astrophysics Data System (ADS)

    Sabin, J.; Bandín, M.; Prieto, G.; Sarmiento, F.

    2009-09-01

    We present a new practical exercise to explain the mechanisms of aggregation of some colloids which are otherwise not easy to understand. We have used tennis balls to simulate, in a visual way, the aggregation of colloids under reaction-limited colloid aggregation (RLCA) and diffusion-limited colloid aggregation (DLCA) regimes. We have used the images of the cluster of balls, following Forrest and Witten's pioneering studies on the aggregation of smoke particles, to estimate their fractal dimension.

  1. Effects of bushings characteristics on suspension ball joint travels

    NASA Astrophysics Data System (ADS)

    Yang, Xiaobo

    2011-02-01

    In this paper, a short-long arm type front suspension is represented using multi-body dynamics model established with ADAMS®, where the suspension bushings modelled as linear and nonlinear elements, respectively, are integrated with a flexible cradle and other suspension components. A ball joint travel, defined as the angular displacement between the two parts connected with the ball joint, is calculated, where the measured wheel loads and spindle accelerations from a proving ground severe durability test schedule serve as the input data. The ball joints considered in this study include lower ball joints, upper ball joints, outer tierod ball joints, and inner tierod ball joints. The results clearly illustrate that the bushing stiffness and nonlinearity are important for an accurate prediction of ball joint travels and the ball joint travel sensitivities to considered design variables are important for engineers to understand and ensure reliable designs of ball joints.

  2. Rotary multiposition valve

    DOEpatents

    Barclay, John A.; Dyson, Jack E.

    1985-01-01

    The disclosure is directed to a rotary multiposition valve for selectively directing the flow of a fluid through a plurality of paths. The valve comprises an inner member and a hollow housing with a row of ducts on its outer surface. The ducts are in fluid communication with the housing. An engaging section of the inner member is received in the housing. A seal divides the engaging section into a hollow inlet segment and a hollow outlet segment. A plurality of inlet apertures are disposed in the inlet segment and a plurality of outlet apertures are disposed in the outlet segment. The inlet apertures are disposed in a longitudinally and radially spaced-apart pattern that can be a helix. The outlet apertures are disposed in a corresponding pattern. As the inner member is rotated, whenever an inlet aperture overlaps one of the ducts, the corresponding outlet aperture overlaps a different duct, thus forming a fluid pathway.

  3. Percutaneous Pulmonary Valve Implantation

    PubMed Central

    Lee, Hyoung-Doo

    2012-01-01

    Pulmonary regurgitation (PR) is a frequent sequelae after repair of tetralogy of Fallot, pulmonary atresia, truncus arteriosus, Rastelli and Ross operation. Due to patient growth and conduit degeneration, these conduits have to be changed frequently due to regurgitation or stenosis. However, morbidity is significant in these repeated operations. To prolong conduit longevity, bare-metal stenting in the right ventricular outflow tract (RVOT) obstruction has been performed. Stenting the RVOT can reduce the right ventricular pressure and symptomatic improvement, but it causes PR with detrimental effects on the right ventricle function and risks of arrhythmia. Percutaneous pulmonary valve implantation has been shown to be a safe and effective treatment for patients with pulmonary valve insufficiency, or stenotic RVOTs. PMID:23170091

  4. Cells need safety valves.

    PubMed

    Danchin, Antoine

    2009-07-01

    In Escherichia coli, the role of lacA, the third gene of the lactose operon, has remained an enigma. I suggest that its role is the consequence of the need for cells to have safety valves that protect them from the osmotic effect created by their permeases. Safety valves allow them to cope with the buildup of osmotic pressure under accidental transient conditions. Multidrug resistance (MDR) efflux, thus named because of our anthropocentrism, is ubiquitous. Yet, the formation of simple leaks would result in futile influx/efflux cycles. Versatile modification enzymes with low sensitivity solve the problem if the modified metabolite is the one exported by MDR permeases. This may account for the pervasive presence of acetyltransferases, such as LacA, associated to acetyl-metabolite exporters. This scenario of constraints imposed by efficient influx of metabolites provides us with a model that should be followed when constructing synthetic cells. PMID:19472369

  5. Rotary multiposition valve

    DOEpatents

    Barclay, J.A.; Dyson, J.E.

    1984-04-06

    The disclosure is directed to a rotary multiposition valve for selectively directing the flow of a fluid through a plurality of paths. The valve comprises an inner member and a hollow housing with a row of ducts on its outer surface. The ducts are in fluid communication with the housing. An engaging section of the inner member is received in the housing. A seal divides the engaging section into a hollow inlet segment and a hollow outlet segment. A plurality of inlet apertures are disposed in the inlet sgegment and a plurality of outlet apertures are disposed in the outlet segment. The inlet apertures are disposed in a longitudinally and radially spaced-apart pattern that can be a helix. The outlet apertures are disposed in a corresponding pattern. As the inner member is rotated, whenever an inlet aperture overlaps one of the ducts, the corresponding outlet aperture overlaps a different duct, thus forming a fluid pathway.

  6. Aspergillus prosthetic valve endocarditis.

    PubMed Central

    Petheram, I S; Seal, R M

    1976-01-01

    The clinical, laboratory, and histopathological features of seven cases of Aspergillus fumigatus prosthetic valve endocarditis are presented. The exact nature of the lesion, a combination of infective fungal endocarditis and thrombosis on the prosthetic valve, is discussed and the difficulties in clinical diagnosis are emphasized. Helpful indications were sudden unexplained heart failure with the appearance of new murmurs, and emboli to large or medium-sized systemic arteries. Fever and anaemia were inconstant, and in no case was blood culture or precipitin investigation helpful. Spore contamination of operating theatre air was the likely source of infection, and measures taken to overcome this and other predisposing factors are discussed. Since medical diagnosis is usually late and the few reported cures in this condition have included replacement of the prosthesis, early surgical intervention combined with antifungal chemotherapy is advised. Images PMID:788218

  7. Fast-acting valve and uses thereof

    DOEpatents

    Meyer, James A.

    1982-01-01

    A very fast acting valve capable of producing a very well-defined plug of gas suitable for filling a theta pinch vacuum vessel is given. The valve requires no springs, instead being stopped mainly by a nonlinear force. Thus, the valve is not subject to bouncing; and the ratio of the size of the valve housing to the size of the valve stem is smaller than it would be if springs were needed to stop the valve stem. Furthermore, the valve can be used for thousands of valve firings with no apparent valve damage.

  8. Fast-acting valve and uses thereof

    DOEpatents

    Meyer, J.A.

    1980-05-16

    A very fast acting valve capable of producing a very well-defined plug of gas suitable for filling a theta pinch vacuum vessel is given. The valve requires no springs, instead being stopped mainly by a nonlinear force. Thus, the valve is not subject to bouncing; and the ratio of the size of the valve housing to the size of the valve stem is smaller than it would be if springs were needed to stop the valve stem. Furthermore, the valve can be used for thousands of valve firings with no apparent valve damage.

  9. PEEK valve seats cut steam losses in R. J. Reynolds tobacco plants

    SciTech Connect

    Not Available

    1986-11-01

    R.J. Reynolds Tobacco Company wanted to reduce large energy losses due to leaky block valves in high temperature and high pressure steam lines throughout its vast cigarette and pipe tobacco production facilities in downtown Winston-Salem, NC. Valves with metal-to-metal seating were being used to control steam at pressures to 160 psi and temperatures over 500/sup 0/F because few resilient valve seat materials could long withstand the severe service conditions. Possible product contamination due to seat wear, fatigue and hydrolysis was also unacceptable. However, metal-seated valves began to leak excessively shortly after being placed in service due to corrosion by boiler water treatment chemicals, and erosion by rust and scale in the steam lines. Steam losses from leaky block valves were excessive. To minimize costly energy losses from leaky steam valves, Reynolds Tobacco engineers evaluated samples of a recently introduced thermoplastic, polyetheretherketone (PEEK), as a seat material for steam service valves. PEEK has excellent flexural and tensile properties for resistance to fatigue and abrasion, and is substantially unaffected after thousands of hours in pressurized water at 480/sup 0/F. The polymer is virtually inert to all chemicals, dissolving only in concentrated sulfuric acid. The 94 V-O flammability rating with negligible toxic gas generation during combustion is also a desirable property in tobacco processing applications. Reynolds Tobacco now has a umber of PEEK-seated ball and butterfly valves that have provided tight shut-off for over four years in high pressure and high temperature steam lines. Some of the test valves have leaked, but the problem was not attributed to failure of the seat material.

  10. Solenoid Valve With Self-Compensation

    NASA Technical Reports Server (NTRS)

    Woeller, Fritz H.; Matsumoto, Yutaka

    1987-01-01

    New solenoid-operated miniature shutoff valve provides self-compensation of differential pressure forces that cause jamming or insufficient valve closure as in single-seal valves. Dual-seal valve is bidirectional. Valve simultaneously seals both inlet and outlet tubes by pressing single disk of silicone rubber against ends of both.

  11. Performance Characteristics of an Isothermal Freeze Valve

    SciTech Connect

    Hailey, A.E.

    2001-08-22

    This document discusses performance characteristics of an isothermal freeze valve. A freeze valve has been specified for draining the DWPF melter at the end of its lifetime. Two freeze valve designs have been evaluated on the Small Cylindrical Melter-2 (SCM-2). In order to size the DWPF freeze valve, the basic principles governing freeze valve behavior need to be identified and understood.

  12. Controlled PCV valve

    SciTech Connect

    Zeigler, T.W. Jr.; Romanczuk, C.S.; Betterton, J.T.; Glover, A.H.

    1987-08-18

    A positive crankcase ventilation control device is described for use with an internal combustion engine and, specifically, for controlling the flow of emission laden vaporous fluids from the crankcase thereof, the control device including selective power means for substantially increasing the flow of emission laden air through the device, comprising: a generally hollow housing with an inlet forming portion adapted to be fluidly connected to the interior spaces of an internal combustion engine to receive emission laden air therefrom; the housing having an outlet forming device adapted to be fluidly connected to the air and fuel inletting portion of the internal combustion engine for disposing of the emission laden air from the engine, the inlet and outlet portions being connected within the interior of the housing by a flow control passage of specific flow area; an elongated valve plug member within the housing and having an end portion with a conically tapered configuration adapted to move progressively into the aforesaid flow control passage thereby decreasing the flow area thereof and, consequently, the total flow through the device; yieldable means urging the elongated valve member toward a position ensuring maximum flow through the flow control passage, but being yieldable to allow the valve member to move so that the conically tapered portion progressively extends further into the flow control passage to thereby decrease the flow area.

  13. Supramolecular spin valves

    NASA Astrophysics Data System (ADS)

    Urdampilleta, M.; Klyatskaya, S.; Cleuziou, J.-P.; Ruben, M.; Wernsdorfer, W.

    2011-07-01

    Magnetic molecules are potential building blocks for the design of spintronic devices. Moreover, molecular materials enable the combination of bottom-up processing techniques, for example with conventional top-down nanofabrication. The development of solid-state spintronic devices based on the giant magnetoresistance, tunnel magnetoresistance and spin-valve effects has revolutionized magnetic memory applications. Recently, a significant improvement of the spin-relaxation time has been observed in organic semiconductor tunnel junctions, single non-magnetic molecules coupled to magnetic electrodes have shown giant magnetoresistance and hybrid devices exploiting the quantum tunnelling properties of single-molecule magnets have been proposed. Herein, we present an original spin-valve device in which a non-magnetic molecular quantum dot, made of a single-walled carbon nanotube contacted with non-magnetic electrodes, is laterally coupled through supramolecular interactions to TbPc2 single-molecule magnets (Pc=phthalocyanine). Their localized magnetic moments lead to a magnetic field dependence of the electrical transport through the single-walled carbon nanotube, resulting in magnetoresistance ratios up to 300% at temperatures less than 1 K. We thus demonstrate the functionality of a supramolecular spin valve without magnetic leads. Our results open up prospects of new spintronic devices with quantum properties.

  14. Supramolecular spin valves.

    PubMed

    Urdampilleta, M; Klyatskaya, S; Cleuziou, J-P; Ruben, M; Wernsdorfer, W

    2011-07-01

    Magnetic molecules are potential building blocks for the design of spintronic devices. Moreover, molecular materials enable the combination of bottom-up processing techniques, for example with conventional top-down nanofabrication. The development of solid-state spintronic devices based on the giant magnetoresistance, tunnel magnetoresistance and spin-valve effects has revolutionized magnetic memory applications. Recently, a significant improvement of the spin-relaxation time has been observed in organic semiconductor tunnel junctions, single non-magnetic molecules coupled to magnetic electrodes have shown giant magnetoresistance and hybrid devices exploiting the quantum tunnelling properties of single-molecule magnets have been proposed. Herein, we present an original spin-valve device in which a non-magnetic molecular quantum dot, made of a single-walled carbon nanotube contacted with non-magnetic electrodes, is laterally coupled through supramolecular interactions to TbPc(2) single-molecule magnets (Pc=phthalocyanine). Their localized magnetic moments lead to a magnetic field dependence of the electrical transport through the single-walled carbon nanotube, resulting in magnetoresistance ratios up to 300% at temperatures less than 1 K. We thus demonstrate the functionality of a supramolecular spin valve without magnetic leads. Our results open up prospects of new spintronic devices with quantum properties. PMID:21685902

  15. The ball SITE sign: Ball sports-induced targetoid erythema in a racquetball player

    PubMed Central

    Cohen, Philip R.

    2015-01-01

    Background: Cutaneous injury following impact of a high velocity ball to the skin may result in either erythema or purpura or both. The lesion typically appears as an annular ring of erythema with or without accompanying ecchymosis when the skin is contacted by a paintball, a ping pong ball, a racquetball or a squash ball. Purpose: To describe a girl with targetoid erythema following impact of a racquetball on her flank and back and to review other sports associated with this response to skin injury. Methods: PubMed was used to search the following terms, separately and in combination: ball, erythema, paint, ping pong, purpura, racquetball, sign, site, sports, squash, targetoid. All papers were reviewed and relevant manuscripts, along with their reference citations, were evaluated. Results: A 13-year-old girl developed an annular red ring surrounding a central area of normal appearing skin on her right flank and upper back where a racquetball traveling at a high velocity contacted her skin. Similar appearing lesions of targetoid erythema have been described at the cutaneous impact sites of either paintballs, ping pong balls, squash balls; in addition to erythema, purpura may also concurrently appear or subsequently develop at the contact location of the ball with the skin. Conclusions: Targetoid erythema is a pathognomonic cutaneous presentation resulting from the impact of either a paintball, ping pong ball, racquetball or squash ball—that is traveling at a high velocity—with a sport participant’s skin. The ball SITE (sports-induced targetoid erythema) sign is suggested as a unifying nomenclature to designate this unique, ball sport-associated, cutaneous dermatosis in athletes participating in sports in which high velocity impact of the ball with the skin may occur. PMID:26336625

  16. Semi-active compressor valve

    DOEpatents

    Brun, Klaus; Gernentz, Ryan S.

    2010-07-27

    A method and system for fine-tuning the motion of suction or discharge valves associated with cylinders of a reciprocating gas compressor, such as the large compressors used for natural gas transmission. The valve's primary driving force is conventional, but the valve also uses an electromagnetic coil to sense position of the plate (or other plugging element) and to provide an opposing force prior to impact.

  17. Streamline coal slurry letdown valve

    DOEpatents

    Platt, R.J.; Shadbolt, E.A.

    1983-11-08

    A streamlined coal slurry letdown valve is featured which has a two-piece throat comprised of a seat and seat retainer. The two-piece design allows for easy assembly and disassembly of the valve. A novel cage holds the two-piece throat together during the high pressure letdown. The coal slurry letdown valve has long operating life as a result of its streamlined and erosion-resistance surfaces. 5 figs.

  18. Streamline coal slurry letdown valve

    DOEpatents

    Platt, Robert J.; Shadbolt, Edward A.

    1983-01-01

    A streamlined coal slurry letdown valve is featured which has a two-piece throat comprised of a seat and seat retainer. The two-piece design allows for easy assembly and disassembly of the valve. A novel cage holds the two-piece throat together during the high pressure letdown. The coal slurry letdown valve has long operating life as a result of its streamlined and erosion-resistance surfaces.

  19. Sequenced drive for rotary valves

    DOEpatents

    Mittell, Larry C.

    1981-01-01

    A sequenced drive for rotary valves which provides the benefits of applying rotary and linear motions to the movable sealing element of the valve. The sequenced drive provides a close approximation of linear motion while engaging or disengaging the movable element with the seat minimizing wear and damage due to scrubbing action. The rotary motion of the drive swings the movable element out of the flowpath thus eliminating obstruction to flow through the valve.

  20. Double-disc gate valve

    DOEpatents

    Wheatley, Seth J.

    1979-01-01

    This invention relates to an improvement in a conventional double-disc gate valve having a vertically movable gate assembly including a wedge, spreaders slidably engaged therewtih, a valve disc carried by the spreaders. When the gate assembly is lowered to a selected point in the valve casing, the valve discs are moved transversely outward to close inlet and outlet ports in the casing. The valve includes hold-down means for guiding the disc-and-spreader assemblies as they are moved transversely outward and inward. If such valves are operated at relatively high differential pressures, they sometimes jam during opening. Such jamming has been a problem for many years in gate valves used in gaseous diffusion plants for the separtion of uranium isotopes. The invention is based on the finding that the above-mentioned jamming results when the outlet disc tilts about its horizontal axis in a certain way during opening of the valve. In accordance with the invention, tilting of the outlet disc is maintained at a tolerable value by providing the disc with a rigid downwardly extending member and by providing the casing with a stop for limiting inward arcuate movement of the member to a preselected value during opening of the valve.

  1. Potential flow in engine valves

    NASA Technical Reports Server (NTRS)

    Eck, Bruno

    1925-01-01

    The extensive applicability of the hydrodynamic theory to the problems of engine construction is clearly shown in the following attempt to determine by exact methods the nature of the flow in valves under variously restricted conditions. Observation shows that two principal kinds of flow occur in simple flat-seated valves. For small valve lifts, the flow is along the horizontal wall and is therefore deflected 90 degrees, but for greater valve lifts the flow separates and forms a free stream, whose angle of deflection naturally increases with increasing lift. Both these kinds of flow can, in fact, be theoretically explained

  2. Mitral Valve Prolapse in Pregnancy

    PubMed Central

    Yuan, Shi-Min; Yan, Song-Li

    2016-01-01

    Mitral valve prolapse is a benign condition. Mitral regurgitation is only complicated in patients with severe mitral valve prolapse. Women with mitral valve prolapse in the absence of other cardiovascular disorders tolerate pregnancy well and do not develop remarkable cardiac complications. Nevertheless, serious complications of mitral valve prolapse, including arrhythmia, infective endocarditis and cerebral ischemic events, can be present in pregnancy. Debates remain with regard to the use of prophylactic antibiotics and β-blockers in the pregnant women with mitral valve prolapse. The prognosis of the pregnant patients might be closely related to the pathological and (or) functional changes of the mitral valve. Non-myxomatous mitral valve prolapse poses no or little obstetric risks in terms of pregnancy, labor and neonatal complications; whereas myxomatous mitral valve prolapse is a major etiology of valvular heart disease in women of childbearing age. In the pregnant patients with mitral valve prolapse progressing into major complications, surgical interventions are considered. Medicinal treatment of such patients with β-blockers should be a concern for the fetal safety. PMID:27556316

  3. Innovative Stemless Valve Eliminates Emissions

    NASA Technical Reports Server (NTRS)

    2008-01-01

    Big Horn Valve Inc. (BHVI), of Sheridan, Wyoming, won a series of SBIR and Small Business Technology Transfer (STTR) contracts with Kennedy Space Center and Marshall Space Flight Center to explore and develop a revolutionary valve technology. BHVI developed a low-mass, high-efficiency, leak-proof cryogenic valve using composites and exotic metals, and had no stem-actuator, few moving parts, with an overall cylindrical shape. The valve has been installed at a methane coal gas field, and future applications are expected to include in-flight refueling of military aircraft, high-volume gas delivery systems, petroleum refining, and in the nuclear industry.

  4. Latest design of gate valves

    SciTech Connect

    Kurzhofer, U.; Stolte, J.; Weyand, M.

    1996-12-01

    Babcock Sempell, one of the most important valve manufacturers in Europe, has delivered valves for the nuclear power industry since the beginning of the peaceful application of nuclear power in the 1960s. The latest innovation by Babcock Sempell is a gate valve that meets all recent technical requirements of the nuclear power technology. At the moment in the United States, Germany, Sweden, and many other countries, motor-operated gate and globe valves are judged very critically. Besides the absolute control of the so-called {open_quotes}trip failure,{close_quotes} the integrity of all valve parts submitted to operational forces must be maintained. In case of failure of the limit and torque switches, all valve designs have been tested with respect to the quality of guidance of the gate. The guidances (i.e., guides) shall avoid a tilting of the gate during the closing procedure. The gate valve newly designed by Babcock Sempell fulfills all these characteristic criteria. In addition, the valve has cobalt-free seat hardfacing, the suitability of which has been proven by friction tests as well as full-scale blowdown tests at the GAP of Siemens in Karlstein, West Germany. Babcock Sempell was to deliver more than 30 gate valves of this type for 5 Swedish nuclear power stations by autumn 1995. In the presentation, the author will report on the testing performed, qualifications, and sizing criteria which led to the new technical design.

  5. Valve-in-Valve-in-Valve Transcatheter Aortic Valve Implantation to Treat a Degenerated Surgical Bioprosthesis in a Subaortic Position

    PubMed Central

    Nuis, Rutger-Jan; Benitez, Luis M.; Nader, Carlos A.; Perez, Sergio; de Marchena, Eduardo J.; Dager, Antonio E.

    2013-01-01

    Transcatheter aortic valve implantation for aortic stenosis has evolved as an alternative treatment for patients who are at high or excessive surgical risk. We report the case of an 84-year-old man with a degenerated surgically implanted valve in a subaortic position (9 mm below the native annulus) who underwent “valve-in-valve” transcatheter aortic valve implantation with use of a Medtronic CoreValve system. We planned to deploy the CoreValve at a conventional depth in the left ventricular outflow tract; we realized that this might result in paravalvular regurgitation, but it would also afford a “deep” landing site for a second valve, if necessary. Ultimately, we implanted a second CoreValve deep in the left ventricular outflow tract to seal a paravalvular leak. The frame of the first valve—positioned at the conventional depth—enabled secure anchoring of the second valve in a deeper position, which in turn effected successful treatment of the failing subaortic surgical prosthesis without paravalvular regurgitation. PMID:23914032

  6. Almanac 2014: aortic valve disease.

    PubMed

    Otto, Catherine M

    2015-06-01

    The past few years have seen major advances in the diagnosis of aortic valve disease and in our understanding of the pathophysiology of disease. In addition, transcatheter aortic valve implantation has transformed our clinical management options. This article summarises new aortic valve disease research published in Heart in 2013 and 2014, within the context of other major studies published in general medical journals, including a discussion of the potential impact of these new research findings on the clinical approach to management of adults with aortic valve disease.

  7. Prosthetic valve endocarditis: an overview.

    PubMed

    Gnann, J W; Dismukes, W E

    1983-12-01

    Infection of an intracardiac prosthesis, the incidence of which is about 2.5% among patients having undergone valve replacement, is a serious complication with considerable morbidity and mortality. Early prosthetic valve endocarditis (PVE), with an onset within 60 days of valve replacement, accounts for approximately one-third of all cases, while the remaining two-thirds, occur more than two months postoperatively (late prosthetic valve endocarditis). Prosthetic valve endocarditis is most commonly caused by Staphylococcus epidermidis, less frequently by viridans streptococci, Staphylococcus aureus, and gram-negative bacilli. The most likely pathogenetic mechanisms in prosthetic valve endocarditis are intraoperative contamination and postoperative infections at extracardiac sites. Prominent clinical features include fever, new or changing heart murmurs, leukocytosis, anemia and hematuria. The etiologic microorganism can be isolated in more than 90% of all cases. Patients with proven prosthetic valve endocarditis should be examined daily to detect signs of congestive heart failure and changes in murmurs; electrocardiographic monitoring is essential for documentation of arrhythmias. With limitations, echocardiography, especially two-dimensional, may help to demonstrate vegetations or valvular dehiscence. Cinefluoroscopy may reveal loosening or dehiscence of the sewing ring or impaired motion of a radio-opaque poppet due to thrombus or vegetation. Cardiac catheterization, not always necessary even when surgical intervention is anticipated, may provide valuable information on the degree of dysfunction, multiple valve involvement, left ventricular function and extent of concomitant coronary artery disease. In patients with mechanical valves, prosthetic valve endocarditis may be associated with a high incidence of valve ring and myocardial abscesses; the reported frequency of valve ring abscesses is lower with porcine heterografts. Infections on mechanical valves

  8. Aerodynamic drag of modern soccer balls.

    PubMed

    Asai, Takeshi; Seo, Kazuya

    2013-12-01

    Soccer balls such as the Adidas Roteiro that have been used in soccer tournaments thus far had 32 pentagonal and hexagonal panels. Recently, the Adidas Teamgeist II and Adidas Jabulani, respectively having 14 and 8 panels, have been used at tournaments; the aerodynamic characteristics of these balls have not yet been verified. Now, the Adidas Tango 12, having 32 panels, has been developed for use at tournaments; therefore, it is necessary to understand its aerodynamic characteristics. Through a wind tunnel test and ball trajectory simulations, this study shows that the aerodynamic resistance of the new 32-panel soccer ball is larger in the high-speed region and lower in the middle-speed region than that of the previous 14- and 8-panel balls. The critical Reynolds number of the Roteiro, Teamgeist II, Jabulani, and Tango 12 was ~2.2 × 10(5) (drag coefficient, C d  ≈ 0.12), ~2.8 × 10(5) (C d  ≈ 0.13), ~3.3 × 10(5) (C d  ≈ 0.13), and ~2.4 × 10(5) (C d  ≈ 0.15), respectively. The flight trajectory simulation suggested that the Tango 12, one of the newest soccer balls, has less air resistance in the medium-speed region than the Jabulani and can thus easily acquire large initial velocity in this region. It is considered that the critical Reynolds number of a soccer ball, as considered within the scope of this experiment, depends on the extended total distance of the panel bonds rather than the small designs on the panel surfaces.

  9. Low energy high pressure miniature screw valve

    DOEpatents

    Fischer, Gary J.; Spletzer, Barry L.

    2006-12-12

    A low energy high pressure screw valve having a valve body having an upper portion and a lower portion, said lower portion of said valve body defining an inlet flow passage and an outlet flow passage traversing said valve body to a valve seat, said upper portion of said valve body defining a cavity at said valve seat, a diaphragm restricting flow between said upper portion of said valve body and said lower portion, said diaphragm capable of engaging said valve seat to restrict fluid communication between said inlet passage and said outlet passage, a plunger within said cavity supporting said diaphragm, said plunger being capable of engaging said diaphragm with said valve seat at said inlet and outlet fluid passages, said plunger being in point contact with a drive screw having threads engaged with opposing threads within said upper portion of said valve body such engagement allowing motion of said drive screw within said valve body.

  10. All metal valve structure for gas systems

    DOEpatents

    Baker, Ray W.; Pawlak, Donald A.; Ramey, Alford J.

    1984-11-13

    A valve assembly with a resilient metal seat member is disclosed for providing a gas-tight seal in a gas handling system. The valve assembly also includes a valve element for sealing against the valve seat member; and an actuating means for operating the valve element. The valve seat member is a one-piece stainless steel ring having a central valve port and peripheral mounting flange, and an annular corrugation in between. A groove between the first and second ridges serves as a flexure zone during operation of the valve member and thus provides the seating pressure between the inner ridge or valve seat and the valve element. The outer annular ridge has a diameter less than said valve element to limit the seating motion of the valve element, preventing non-elastic deformation of the seat member.

  11. Ball machine usage in tennis: movement initiation and swing timing while returning balls from a ball machine and from a real server.

    PubMed

    Carboch, Jan; Süss, Vladimir; Kocib, Tomas

    2014-05-01

    Practicing with the use of a ball machine could handicap a player compared to playing against an actual opponent. Recent studies have shown some differences in swing timing and movement coordination, when a player faces a ball projection machine as opposed to a human opponent. We focused on the time of movement initiation and on stroke timing during returning tennis serves (simulated by a ball machine or by a real server). Receivers' movements were measured on a tennis court. In spite of using a serving ball speed from 90 kph to 135 kph, results showed significant differences in movement initiation and backswing duration between serves received from a ball machine and serves received from a real server. Players had shorter movement initiation when they faced a ball machine. Backswing duration was longer for the group using a ball machine. That demonstrates different movement timing of tennis returns when players face a ball machine. Use of ball machines in tennis practice should be limited as it may disrupt stroke timing. Key pointsPlayers have shorter initial move time when they are facing the ball machine.Using the ball machine results in different swing timing and movement coordination.The use of the ball machine should be limited.

  12. Ball machine usage in tennis: movement initiation and swing timing while returning balls from a ball machine and from a real server.

    PubMed

    Carboch, Jan; Süss, Vladimir; Kocib, Tomas

    2014-05-01

    Practicing with the use of a ball machine could handicap a player compared to playing against an actual opponent. Recent studies have shown some differences in swing timing and movement coordination, when a player faces a ball projection machine as opposed to a human opponent. We focused on the time of movement initiation and on stroke timing during returning tennis serves (simulated by a ball machine or by a real server). Receivers' movements were measured on a tennis court. In spite of using a serving ball speed from 90 kph to 135 kph, results showed significant differences in movement initiation and backswing duration between serves received from a ball machine and serves received from a real server. Players had shorter movement initiation when they faced a ball machine. Backswing duration was longer for the group using a ball machine. That demonstrates different movement timing of tennis returns when players face a ball machine. Use of ball machines in tennis practice should be limited as it may disrupt stroke timing. Key pointsPlayers have shorter initial move time when they are facing the ball machine.Using the ball machine results in different swing timing and movement coordination.The use of the ball machine should be limited. PMID:24790483

  13. Ball Machine Usage in Tennis: Movement Initiation and Swing Timing While Returning Balls from a Ball Machine and from a Real Server

    PubMed Central

    Carboch, Jan; Süss, Vladimir; Kocib, Tomas

    2014-01-01

    Practicing with the use of a ball machine could handicap a player compared to playing against an actual opponent. Recent studies have shown some differences in swing timing and movement coordination, when a player faces a ball projection machine as opposed to a human opponent. We focused on the time of movement initiation and on stroke timing during returning tennis serves (simulated by a ball machine or by a real server). Receivers’ movements were measured on a tennis court. In spite of using a serving ball speed from 90 kph to 135 kph, results showed significant differences in movement initiation and backswing duration between serves received from a ball machine and serves received from a real server. Players had shorter movement initiation when they faced a ball machine. Backswing duration was longer for the group using a ball machine. That demonstrates different movement timing of tennis returns when players face a ball machine. Use of ball machines in tennis practice should be limited as it may disrupt stroke timing. Key points Players have shorter initial move time when they are facing the ball machine. Using the ball machine results in different swing timing and movement coordination. The use of the ball machine should be limited. PMID:24790483

  14. The dynamic impact characteristics of tennis balls with tennis rackets.

    PubMed

    Haake, S J; Carré, M J; Goodwill, S R

    2003-10-01

    The dynamic properties of six types of tennis balls were measured using a force platform and high-speed digital video images of ball impacts on rigidly clamped tennis rackets. It was found that the coefficient of restitution reduced with velocity for impacts on a rigid surface or with a rigidly clamped tennis racket. Pressurized balls had the highest coefficient of restitution, which decreased by 20% when punctured. Pressureless balls had a coefficient of restitution approaching that of a punctured ball at high speeds. The dynamic stiffness of the ball or the ball-racket system increased with velocity and pressurized balls had the highest stiffness, which decreased by 35% when punctured. The characteristics of pressureless balls were shown to be similar to those of punctured balls at high velocity and it was found that lowering the string tension produced a smaller range of stiffness or coefficient of restitution. It was hypothesized that players might consider high ball stiffness to imply a high coefficient of restitution. Plots of coefficient of restitution versus stiffness confirmed the relationship and it was found that, generally, pressurized balls had a higher coefficient of restitution and stiffness than pressureless balls. The players might perceive these parameters through a combination of sound, vibration and perception of ball speed off the racket. PMID:14620027

  15. Flight trajectory of a rotating golf ball with grooves

    NASA Astrophysics Data System (ADS)

    Baek, Moonheum; Kim, Jooha; Choi, Haecheon

    2014-11-01

    Dimples are known to reduce drag on a sphere by the amount of 50% as compared to a smooth surface. Despite the advantage of reducing drag, dimples deteriorate the putting accuracy owing to their sharp edges. To minimize this putting error but maintain the same flight distance, we have devised a grooved golf ball (called G ball hereafter) for several years. In this study, we modify the shape and pattern of grooves, and investigate the flow characteristics of the G ball by performing wind-tunnel experiments at the Reynolds numbers of 0 . 5 ×105 - 2 . 5 ×105 and the spin ratios (ratio of surface velocity to the free-stream velocity) of 0 - 0.6 that include the real golf-ball velocity and rotational speed. We measure the drag and lift forces on the rotating G ball and compare them with those of a smooth ball and two well-known dimpled balls. The lift-to-drag ratio of the G ball is much higher than that of a smooth ball and is in between those of the two dimpled balls. The trajectories of flying golf balls are computed. The flight distance of G ball is almost the same as that of one dimpled ball but slightly shorter than that of the other dimpled ball. The fluid-dynamic aspects of these differences will be discussed at the talk. Supported by 2011-0028032, 2014M3C1B1033980.

  16. Transcatheter Valve-in-Valve: A Cautionary Tale.

    PubMed

    Luc, Jessica G Y; Shanks, Miriam; Tyrrell, Benjamin D; Welsh, Robert C; Butler, Craig R; Meyer, Steven R

    2016-09-01

    Transcatheter aortic valve replacement (TAVR) by valve-in-valve (VIV) implantation is an alternative treatment for high-risk patients with a degenerating aortic bioprosthesis. We present a case of transapical TAVR VIV with a 29-mm Edwards SAPIEN XT (ESV) (Edwards Lifesciences, Irvine, CA) into a 29-mm Medtronic Freestyle stentless bioprosthesis (Medtronic Inc, Minneapolis, MN) in which unanticipated dilatation of the Freestyle bioprosthesis resulted in intraprocedural embolization of the TAVR valve, necessitating urgent conversion to a conventional surgical aortic valve replacement (AVR). Our experience suggests that TAVR VIV with the 29-mm ESV in the setting of a degenerated 29-mm Freestyle stentless bioprosthesis must be undertaken with caution. PMID:27549545

  17. Silicon ball grid array chip carrier

    DOEpatents

    Palmer, David W.; Gassman, Richard A.; Chu, Dahwey

    2000-01-01

    A ball-grid-array integrated circuit (IC) chip carrier formed from a silicon substrate is disclosed. The silicon ball-grid-array chip carrier is of particular use with ICs having peripheral bond pads which can be reconfigured to a ball-grid-array. The use of a semiconductor substrate such as silicon for forming the ball-grid-array chip carrier allows the chip carrier to be fabricated on an IC process line with, at least in part, standard IC processes. Additionally, the silicon chip carrier can include components such as transistors, resistors, capacitors, inductors and sensors to form a "smart" chip carrier which can provide added functionality and testability to one or more ICs mounted on the chip carrier. Types of functionality that can be provided on the "smart" chip carrier include boundary-scan cells, built-in test structures, signal conditioning circuitry, power conditioning circuitry, and a reconfiguration capability. The "smart" chip carrier can also be used to form specialized or application-specific ICs (ASICs) from conventional ICs. Types of sensors that can be included on the silicon ball-grid-array chip carrier include temperature sensors, pressure sensors, stress sensors, inertia or acceleration sensors, and/or chemical sensors. These sensors can be fabricated by IC processes and can include microelectromechanical (MEM) devices.

  18. Dark matter balls help supernovae to explode

    NASA Astrophysics Data System (ADS)

    Froggatt, C. D.; Nielsen, H. B.

    2015-10-01

    As a solution to the well-known problem that the shock wave potentially responsible for the explosion of a supernova actually tends to stall, we propose a new energy source arising from our model for dark matter. Our earlier model proposed that dark matter should consist of cm-large white dwarf-like objects kept together by a skin separating two different sorts of vacua. These dark matter balls or pearls will collect in the middle of any star throughout its lifetime. At some stage during the development of a supernova, the balls will begin to take in neutrons and then other surrounding material. By passing into a ball nucleons fall through a potential of order 10 MeV, causing a severe production of heat — of order 10 foe for a solar mass of material eaten by the balls. The temperature in the iron core will thereby be raised, splitting up the iron into smaller nuclei. This provides a mechanism for reviving the shock wave when it arrives and making the supernova explosion really occur. The onset of the heating due to the dark matter balls would at first stop the collapse of the supernova progenitor. This opens up the possibility of there being two collapses giving two neutrino outbursts, as apparently seen in the supernova SN1987A — one in Mont Blanc and one 4 h 43 min later in both IMB and Kamiokande.

  19. Role of visual information in ball catching.

    PubMed

    Rosengren, K S; Pick, H L; von Hofsten, C

    1988-06-01

    The present study is concerned with the perceptual information about the body and space underlying the act of catching a ball. In a series of four experiments, subjects were asked to catch a luminous ball under various visual conditions. In general, catching in a normally illuminated room was contrasted with catching the luminous ball in an otherwise completely dark room. In the third and fourth experiments, intermediate conditions of visual information were included. The results suggest that it is possible to catch a ball with one hand when only the ball is visible, but performance is better when the subject has the benefit of a rich visual environment and two hands. The second experiment indicated that subject performance does improve with practice in the dark, but time spent in the darkened room itself doesn't result in a significant decrement in performance. Results of the third study suggest that vision of one's hand does not aid in the performance of this task whereas the presence of a minimal visual frame appears to aid performance. The final study examined the relation between catching performance and body sway under similar visual conditions. Results of this experiment imply that persons who exhibit relatively little postural sway in full-room lighting performed better at this catching task.

  20. Results of the unidirectional Centri-Safe arterial valve for prevention of retrograde flow during cardiopulmonary bypass.

    PubMed

    Esper, E; Devineni, R; Shah, N S; Wurzel, D; Brownstein, L; Heagney, M G; Slukis, M J; Kolff, J

    1994-01-01

    Retrograde blood from the aortic cannula into the cardiopulmonary circuit may lead to aortic air emboli when nonocclusive centrifugal pumps are used. The authors tested a nonregurgitant, unidirectional valve containing a Teflon ball occluder to prevent backflow. In vitro measurements of leakage rate, forward flow pressure drop, burst strength, and hemolysis levels along with animal (n = 12) and human (n = 12) in vivo hematologic and hemolysis levels were measured. Data were analyzed by paired and unpaired Student's t-test. Pressure drop differences at flows of 5 l/min were 7.3 +/- 0.3 mmHg before and 7.6 +/- 0.1 mmHg after 10,800 cycles of pulsatile pumping. (P = NS). Leakage rate during this period at pressures of 100 mmHg was not significant. Volume required to close the Teflon ball was less than 1 ml. Hemolysis analysis done in vitro and in vivo in control (no valve) and experimental (valve) groups used hemoglobin, hematocrit, platelets, plasma free hemoglobin, and lactic dehydrogenase as hemolysis indices. There were no statistical differences. The authors conclude that the CentriSafe valve (Cardiac Systems, Inc., Conshohocken, PA) is safe and prevents fatal backflow and air emboli. The valve is nonthrombotic in anticoagulated blood, can be opened and closed thousands of times, and has a burst strength equal to or greater than other components in the perfusion setup.

  1. Combination throttle and shutoff valve

    NASA Technical Reports Server (NTRS)

    Carriker, J. W.

    1972-01-01

    Combination of translating sleeve throttle valve and conventional poppet valve provides capability of shutting off flow completely by poppet and sleeve control of the rate of flow. Integration of the two concepts can be accomplished without difficulty and in a manner that requires a minimum of development.

  2. Surge-damping vacuum valve

    DOEpatents

    Bullock, Jack C.; Kelly, Benjamin E.

    1980-01-01

    A valve having a mechanism for damping out flow surges in a vacuum system which utilizes a slotted spring-loaded disk positioned adjacent the valve's vacuum port. Under flow surge conditions, the differential pressure forces the disk into sealing engagement with the vacuum port, thereby restricting the flow path to the slots in the disk damping out the flow surge.

  3. Air flow through poppet valves

    NASA Technical Reports Server (NTRS)

    Lewis, G W; Nutting, E M

    1920-01-01

    Report discusses the comparative continuous flow characteristics of single and double poppet valves. The experimental data presented affords a direct comparison of valves, single and in pairs of different sizes, tested in a cylinder designed in accordance with current practice in aviation engines.

  4. Awake transapical aortic valve implantation.

    PubMed

    Petridis, Francesco Dimitri; Savini, Carlo; Castelli, Andrea; Di Bartolomeo, Roberto

    2012-05-01

    Transapical aortic valve implantation is being employed as a less invasive alternative to open heart surgery in high-risk patients with severe aortic stenosis. Here we report the case of an awake transapical aortic valve implantation in a patient with severe chronic obstructive pulmonary disease.

  5. Variable gas leak rate valve

    DOEpatents

    Eernisse, Errol P.; Peterson, Gary D.

    1976-01-01

    A variable gas leak rate valve which utilizes a poled piezoelectric element to control opening and closing of the valve. The gas flow may be around a cylindrical rod with a tubular piezoelectric member encircling the rod for seating thereagainst to block passage of gas and for reopening thereof upon application of suitable electrical fields.

  6. Relativistic-microwave theory of ball lightning.

    PubMed

    Wu, H-C

    2016-06-22

    Ball lightning, a fireball sometimes observed during lightnings, has remained unexplained. Here we present a comprehensive theory for the phenomenon: At the tip of a lightning stroke reaching the ground, a relativistic electron bunch can be produced, which in turn excites intense microwave radiation. The latter ionizes the local air and the radiation pressure evacuates the resulting plasma, forming a spherical plasma bubble that stably traps the radiation. This mechanism is verified by particle simulations. The many known properties of ball lightning, such as the occurrence site, relation to the lightning channels, appearance in aircraft, its shape, size, sound, spark, spectrum, motion, as well as the resulting injuries and damages, are also explained. Our theory suggests that ball lighting can be created in the laboratory or triggered during thunderstorms. Our results should be useful for lightning protection and aviation safety, as well as stimulate research interest in the relativistic regime of microwave physics.

  7. Relativistic-microwave theory of ball lightning.

    PubMed

    Wu, H-C

    2016-01-01

    Ball lightning, a fireball sometimes observed during lightnings, has remained unexplained. Here we present a comprehensive theory for the phenomenon: At the tip of a lightning stroke reaching the ground, a relativistic electron bunch can be produced, which in turn excites intense microwave radiation. The latter ionizes the local air and the radiation pressure evacuates the resulting plasma, forming a spherical plasma bubble that stably traps the radiation. This mechanism is verified by particle simulations. The many known properties of ball lightning, such as the occurrence site, relation to the lightning channels, appearance in aircraft, its shape, size, sound, spark, spectrum, motion, as well as the resulting injuries and damages, are also explained. Our theory suggests that ball lighting can be created in the laboratory or triggered during thunderstorms. Our results should be useful for lightning protection and aviation safety, as well as stimulate research interest in the relativistic regime of microwave physics. PMID:27328835

  8. Electrostatic charge bounds for ball lightning models

    NASA Astrophysics Data System (ADS)

    Stephan, Karl D.

    2008-03-01

    Several current theories concerning the nature of ball lightning predict a substantial electrostatic charge in order to account for its observed motion and shape (Turner 1998 Phys. Rep. 293 1; Abrahamson and Dinniss 2000 Nature 403 519). Using charged soap bubbles as a physical model for ball lightning, we show that the magnitude of charge predicted by some of these theories is too high to allow for the types of motion commonly observed in natural ball lightning, which includes horizontal motion above the ground and movement near grounded conductors. Experiments show that at charge levels of only 10-15 nC, 3-cm-diameter soap bubbles tend to be attracted by induced charges to the nearest grounded conductor and rupture. We conclude with a scaling rule that can be used to extrapolate these results to larger objects and surroundings.

  9. On the energy characteristics of ball lightning.

    PubMed

    Bychkov, A V; Bychkov, V L; Abrahamson, John

    2002-01-15

    A compilation of 17 observations of ball lightning showing the most energetic effects is presented along with estimates of their energy content. These observations were chosen from several thousand for the much stronger interaction of each ball lightning on its surroundings, and the method of energy estimation outlined. The case is put that some of the observations show a higher energy than self-contained chemical energy could provide. Comments have been added to the paper, arguing that the energy estimations themselves should be consistent with whatever model is used for ball lightning. For example, the presence of reacting nanoparticles releasing chemical energy may bring about the same observed effects with lower estimated energy.

  10. Randomness in the bouncing ball dynamics

    NASA Astrophysics Data System (ADS)

    Giusepponi, S.; Marchesoni, F.; Borromeo, M.

    2005-06-01

    The dynamics of a vibrated bouncing ball is studied numerically in the reduced impact representation, where the velocity of the bouncing ball is sampled at each impact with the plate (asynchronous sampling). Its random nature is thus fully revealed: (i) the chattering mechanism, through which the ball gets locked on the plate, is accomplished within a limited interval of the plate oscillation phase, and (ii) is well described in impact representation by a special structure of looped, nested bands and (iii) chattering trajectories and strange attractors may coexist for appropriate ranges of the parameter values. Structure and substructure of the chattering bands are well explained in terms of a simple impact map rule. These results are of potential application to the analysis of high-temperature vibrated granular gases.

  11. On the energy characteristics of ball lightning.

    PubMed

    Bychkov, A V; Bychkov, V L; Abrahamson, John

    2002-01-15

    A compilation of 17 observations of ball lightning showing the most energetic effects is presented along with estimates of their energy content. These observations were chosen from several thousand for the much stronger interaction of each ball lightning on its surroundings, and the method of energy estimation outlined. The case is put that some of the observations show a higher energy than self-contained chemical energy could provide. Comments have been added to the paper, arguing that the energy estimations themselves should be consistent with whatever model is used for ball lightning. For example, the presence of reacting nanoparticles releasing chemical energy may bring about the same observed effects with lower estimated energy. PMID:16210173

  12. Relativistic-microwave theory of ball lightning

    NASA Astrophysics Data System (ADS)

    Wu, H.-C.

    2016-06-01

    Ball lightning, a fireball sometimes observed during lightnings, has remained unexplained. Here we present a comprehensive theory for the phenomenon: At the tip of a lightning stroke reaching the ground, a relativistic electron bunch can be produced, which in turn excites intense microwave radiation. The latter ionizes the local air and the radiation pressure evacuates the resulting plasma, forming a spherical plasma bubble that stably traps the radiation. This mechanism is verified by particle simulations. The many known properties of ball lightning, such as the occurrence site, relation to the lightning channels, appearance in aircraft, its shape, size, sound, spark, spectrum, motion, as well as the resulting injuries and damages, are also explained. Our theory suggests that ball lighting can be created in the laboratory or triggered during thunderstorms. Our results should be useful for lightning protection and aviation safety, as well as stimulate research interest in the relativistic regime of microwave physics.

  13. The bouncing ball through a geometrical series

    NASA Astrophysics Data System (ADS)

    Flores, Sergio; Alfaro, Luis L.; Chavez, Juan E.; Bastarrachea, Aztlan; Hurtado, Jazmin

    2008-10-01

    The mathematical representation of the physical situation related to a bouncing ball on the floor is an important understanding difficulty for most of the students during the introductory mechanics and mathematics courses. The research group named Physics and mathematics in context from the University of Ciudad Juarez is concerned about the versatility in the change from a mathematical representation to the own physical context of any problem under a traditional instruction. In this case, the main idea is the association of the physical properties of the bouncing ball situation to the nearest mathematical model based on a geometrical series. The proposal of the cognitive development is based on a geometrical series that shows the time the ball takes to stop. In addition, we show the behavior of the ratio of the consecutive heights during the motion.

  14. Relativistic-microwave theory of ball lightning

    PubMed Central

    Wu, H.-C.

    2016-01-01

    Ball lightning, a fireball sometimes observed during lightnings, has remained unexplained. Here we present a comprehensive theory for the phenomenon: At the tip of a lightning stroke reaching the ground, a relativistic electron bunch can be produced, which in turn excites intense microwave radiation. The latter ionizes the local air and the radiation pressure evacuates the resulting plasma, forming a spherical plasma bubble that stably traps the radiation. This mechanism is verified by particle simulations. The many known properties of ball lightning, such as the occurrence site, relation to the lightning channels, appearance in aircraft, its shape, size, sound, spark, spectrum, motion, as well as the resulting injuries and damages, are also explained. Our theory suggests that ball lighting can be created in the laboratory or triggered during thunderstorms. Our results should be useful for lightning protection and aviation safety, as well as stimulate research interest in the relativistic regime of microwave physics. PMID:27328835

  15. High pressure gate valve failure

    SciTech Connect

    Place, M. Jr.; Kochera, J.W.

    1995-10-01

    Shell Oil Company was attempting to develop CRA (Corrosion Resistant Alloy) valves for use in those completions utilizing CRA tubing. The testing and development of new materials for CRA valves of both the solid and clad version were pursued. As part of this CRA valve development program, Shell Oil Company tried to reconcile the apparent discrepancy between unacceptable laboratory test results on 410 SS in sour environments with both the apparent success (when properly heat treated and at an acceptable hardness level) of this alloy in commercial sour use and the fact that it is fully accepted in NACE MR-01-75. A410 stainless steel valve was tested near the material yield strength at low H{sub 2}S partial pressures at the STF (Static Test Facility) in Mississippi. The valve failed by crack growth and body wall leakage while under test.

  16. Automatic monitoring of valve status

    SciTech Connect

    Prinz, F.B.; Chern, J.H.

    1988-01-01

    Authors note that acoustic emissions from valves and adjacent pipe, used to investigate the problem of valve leakage in power plants, cannot be separated so as to distinguish leakage processes from other causes of ultrasound emissions. They propose establishing the relationship between valve leaking and thermal gradient to allow detection of valve leakage by observing the piping system`s temperature profile. Authors note that their mathematical and experimental models of a typical power-plant piping section were found inconsistent, report known and suspected reasons for this, and suggest specific further studies to supply missing data. They also suggest designing modern power plants to accommodate a remotely controlled or autonomous vehicle which would carry a device for thermal-gradient leak detection to examine valves in situ.

  17. Packing developments improve valve availability

    SciTech Connect

    Aikin, J.

    1994-01-01

    Regulatory environment and clean air legislation demand improvements in valve stuffing box performance. In normally inaccessible or hazardous areas, the cost of valve maintenance and repair in terms of safety, radiation, and toxic gas exposure is very high. AECL Research`s Mechanical Equipment Development (MED) branch at Chalk River Laboratories (Chalk River, Ont.) has researched stem packing leakage problems since the early 1970s. Early research and development (R and D) significantly improved the understanding of operational characteristics of asbestos-based valve packing. Of note was the development of live loading, a stem packing method that reduces valve leakage to near zero under most operating conditions, and significantly prolongs packing life. This article describes how stem packing developments, including live loading techniques, are reducing valve fugitive emissions and leakage.

  18. Drag Crisis of Gyro-Balls

    NASA Astrophysics Data System (ADS)

    Yokoyama, Yoshiyuki; Miyazaki, Takeshi; Himeno, Ryutaro

    2007-11-01

    Using a high-speed video camera, we measured the trajectory and the rotation of a hard baseball thrown by a pitching machine which can launch Gyro-Balls (rifle spinning balls). We determined the drag- and lift- coefficients by analyzing the video images. The measurements were performed in the range of 0.6x10^5ball with SP=0.12,0.23 and 0.35, decreases gradually with Re. However, the drag coefficient of a 2-seam gyro-ball with SP=0.12 decreases in two steps, i.e. in the ranges 0.8x10^5Ball with SP=0.23,0.35 are almost constant below Re=1.6x10^5 and Re=1.3x10^5, respectively. Their minima are attained at Re=1.8x10^5 and Re=1.6x10^5, respectively. These findings confirm the occurrence of the drag crisis for Gyro-Balls. The different Re-dependencies are due to the different seam patterns.

  19. Mitral Valve Annuloplasty

    PubMed Central

    Rausch, Manuel K.; Bothe, Wolfgang; Kvitting, John-Peder Escobar; Swanson, Julia C.; Miller, D. Craig; Kuhl, Ellen

    2012-01-01

    Mitral valve annuloplasty is a common surgical technique used in the repair of a leaking valve by implanting an annuloplasty device. To enhance repair durability, these devices are designed to increase leaflet coaptation, while preserving the native annular shape and motion; however, the precise impact of device implantation on annular deformation, strain, and curvature is unknown. Here we quantify how three frequently used devices significantly impair native annular dynamics. In controlled in vivo experiments, we surgically implanted eleven flexible-incomplete, eleven semi-rigid-complete, and twelve rigid-complete devices around the mitral annuli of 34 sheep, each tagged with 16 equally-spaced tantalum markers. We recorded four-dimensional marker coordinates using biplane videofluoroscopy, first with device and then without, which were used to create mathematical models using piecewise cubic splines. Clinical metrics (characteristic anatomical distances) revealed significant global reduction in annular dynamics upon device implantation. Mechanical metrics (strain and curvature fields) explained this reduction via a local loss of anterior dilation and posterior contraction. Overall, all three devices unfavorably reduced annular dynamics. The flexible-incomplete device, however, preserved native annular dynamics to a larger extent than the complete devices. Heterogeneous strain and curvature profiles suggest the need for heterogeneous support, which may spawn more rational design of annuloplasty devices using design concepts of functionally graded materials. PMID:22037916

  20. Hydraulic valve lifter

    SciTech Connect

    Kodama, H.; Ono, T.

    1986-11-25

    This patent describes a hydraulic valve lifter mounted in a rocker arm of a valve train assembly of internal combustion engines, the lifter comprising: a cylinder having a cylindrical surface formed in the rocker arm; a plunger reciprocally mounted in the cylinder in sliding contact with the cylindrical surface; a seat member securely pressed in the cylinder above the plunger. The seat member defines a reservoir chamber and a pressure chamber in the cylinder and having an outer circumferential portion extending in contact with the cylindrical surface in a direction of the plunger; a stopper means formed at an end surface of the outer circumferential portion of the seat member for restricting an axial movement of the plunger in a direction of the seat member; and at least one relief means formed in the cylindrical surface above the stopper means for a finishing machining process of the cylinder whereby each recess means is completely covered by the outer circumferential portion of the seat member. In this way, the cylindrical surface encircles the plunger and is formed by an uninterrupted smooth sliding surface along the entire length of movement of the plunger.

  1. Robotic mitral valve surgery.

    PubMed

    Kypson, Alan P; Nifong, L Wiley; Chitwood, W Randolph

    2003-12-01

    A renaissance in cardiac surgery has begun. The early clinical experience with computer-enhanced telemanipulation systems outlines the limitations of this approach despite some procedural success. Technologic advancements, such as the use of nitinol U-clips (Coalescent Surgical Inc., Sunnyvale, CA) instead of sutures requiring manual knot tying, have been shown to decrease operative times significantly. It is expected that with further refinements and development of adjunct technologies, the technique of computer-enhanced endoscopic cardiac surgery will evolve and may prove to be beneficial for many patients. Robotic technology has provided benefits to cardiac surgery. With improved optics and instrumentation, incisions are smaller. The ergometric movements and simulated three-dimensional optics project hand-eye coordination for the surgeon. The placement of the wristlike articulations at the end of the instruments moves the pivoting action to the plane of the mitral annulus. This improves dexterity in tight spaces and allows for ambidextrous suture placement. Sutures can be placed more accurately because of tremor filtration and high-resolution video magnification. Furthermore, the robotic system may have potential as an educational tool. In the near future, surgical vision and training systems might be able to model most surgical procedures through immersive technology. Thus, a "flight simulator" concept emerges where surgeons may be able to practice and perform the operation without a patient. Already, effective curricula for training teams in robotic surgery exist. Nevertheless, certain constraints continue to limit the advancement to a totally endoscopic computer-enhanced mitral valve operation. The current size of the instruments, intrathoracic instrument collisions, and extrathoracic "elbow" conflicts still can limit dexterity. When smaller instruments are developed, these restraints may be resolved. Furthermore, a working port incision is still required for

  2. A formula for comparison of selected sport ball compressibility.

    PubMed Central

    Dowell, L J; Krebs, G

    1991-01-01

    The purpose of this study was to develop a formula to determine and compare the compressibility of selected sport balls. Six balls (basketball, volleyball, soccer ball, baseball, handball, golf ball) were dropped ten times from each of four different heights onto a smooth solid surface overlaid with a white sheet of typing paper, overlaid with a sheet of carbon paper. The diameter of the area of contact of each ball imprinted onto the typing paper was measured in millimetres with calipers. From the data, the distance (d) that each ball compressed for each velocity (v) was calculated. It was found that a linear relationship existed between velocity at impact and the distance for each ball studied. The compressibility coefficient (c) for each ball was calculated and a formula was developed to determine the distance each ball would compress at a given velocity. When velocity is measured in metres per second and the distance a ball compresses is measured in millimetres, the formula to determine d for selected balls, in order of compressibility is: basketball d = 3.07v, volleyball d = 2.90v, soccer ball d = 2.80v, baseball d = 0.77v, handball d = 0.53v, and golf ball d = 0.17v. PMID:1913029

  3. A formula for comparison of selected sport ball compressibility.

    PubMed

    Dowell, L J; Krebs, G

    1991-03-01

    The purpose of this study was to develop a formula to determine and compare the compressibility of selected sport balls. Six balls (basketball, volleyball, soccer ball, baseball, handball, golf ball) were dropped ten times from each of four different heights onto a smooth solid surface overlaid with a white sheet of typing paper, overlaid with a sheet of carbon paper. The diameter of the area of contact of each ball imprinted onto the typing paper was measured in millimetres with calipers. From the data, the distance (d) that each ball compressed for each velocity (v) was calculated. It was found that a linear relationship existed between velocity at impact and the distance for each ball studied. The compressibility coefficient (c) for each ball was calculated and a formula was developed to determine the distance each ball would compress at a given velocity. When velocity is measured in metres per second and the distance a ball compresses is measured in millimetres, the formula to determine d for selected balls, in order of compressibility is: basketball d = 3.07v, volleyball d = 2.90v, soccer ball d = 2.80v, baseball d = 0.77v, handball d = 0.53v, and golf ball d = 0.17v. PMID:1913029

  4. A formula for comparison of selected sport ball compressibility.

    PubMed

    Dowell, L J; Krebs, G

    1991-03-01

    The purpose of this study was to develop a formula to determine and compare the compressibility of selected sport balls. Six balls (basketball, volleyball, soccer ball, baseball, handball, golf ball) were dropped ten times from each of four different heights onto a smooth solid surface overlaid with a white sheet of typing paper, overlaid with a sheet of carbon paper. The diameter of the area of contact of each ball imprinted onto the typing paper was measured in millimetres with calipers. From the data, the distance (d) that each ball compressed for each velocity (v) was calculated. It was found that a linear relationship existed between velocity at impact and the distance for each ball studied. The compressibility coefficient (c) for each ball was calculated and a formula was developed to determine the distance each ball would compress at a given velocity. When velocity is measured in metres per second and the distance a ball compresses is measured in millimetres, the formula to determine d for selected balls, in order of compressibility is: basketball d = 3.07v, volleyball d = 2.90v, soccer ball d = 2.80v, baseball d = 0.77v, handball d = 0.53v, and golf ball d = 0.17v.

  5. Ocular injuries from liquid golf ball cores.

    PubMed Central

    Lucas, D R; Dunham, A C; Lee, W R; Weir, W; Wilkinson, F C

    1976-01-01

    Tissue removed from nine new cases from 18 hours to 20 weeks after injury by a golf ball contained crystalline and other foreign material to which there was a mild inflammatory reaction followed by macrophagic activity and fibrosis. Optical and electron probe analysis showed that the crystalline material was crushed barytes containing small quantities of muscovite as is typical in natural deposits. The centres of several golf balls were shown to contain essentially identical material. By contrast with previous reports, no zinc sulphide was found. The form and frequent location of the deposits in the conjunctiva as compared with cornea and eyelid is related to the structure of these tissues. Images PMID:1009050

  6. Patents and heart valve surgery - II: tissue valves.

    PubMed

    Cheema, Faisal H; Kossar, Alexander P; Rehman, Atiq; Younas, Fahad; Polvani, Gianluca

    2013-08-01

    Valvular heart disease affects millions of Americans yearly and currently requires surgical intervention to repair or replace the defective valves. Through a close-knit collaboration between physicians, scientists and biomedical engineers, a vast degree of research and development has been aimed towards the optimization of prosthetic heart valves. Although various methods have made fantastic strides in producing durable prostheses, the therapeutic efficacy of prosthetic valves is inherently limited by a dependency upon lifelong anticoagulant regimens for recipients - a difficult challenge for many in clinical setting. Thus, biological tissue valves have been developed to circumvent vascular and immunemediated complications by incorporating biological materials to mimic native valves while still maintaining a necessary level of structural integrity. Over the past decade, a multitude of patents pertaining to the refinement of designs as well as the advancement in methodologies and technologies associated with biological tissue valves have been issued. This review seeks to chronicle and characterize such patents in an effort to track the past, present, and future progress as well as project the trajectory of tissue valves in the years to come.

  7. Valve-related complications after mechanical heart valve implantation.

    PubMed

    Misawa, Yoshio

    2015-10-01

    The number of heart valve surgeries is increasing, and 19,164 patients underwent heart valve surgery in Japan in 2011. The early mortality rate has remained stable for more than 10 years. Many patients now survive for many years, with a reported 10-year survival rate of at least 60 %. However, unfavorable complications can occur after valve surgery. Valve-related complications include thromboembolisms, bleeding complications and prosthetic valve endocarditis, followed by structural and nonstructural prosthetic valve dysfunctions. Our review of studies published after 2000 revealed that the rate of all valve-related complications was 0.7-3.5 % per patient-year. Thromboembolisms occur at a rate of approximately 1 % per patient-year, and bleeding complications occur at almost 0.5 % per patient-year. Thromboembolic and hemorrhagic events related to anticoagulant therapy should be considered during life-long follow-up. The occurrence rate of endocarditis reaches 0.5 % per patient-year, with a poor postoperative survival. Structural dysfunctions have been largely overcome, and the nonstructural dysfunction rate is 0.4-1.2 % per patient-year. The nonstructural dysfunctions induced by paravalvular leaks and pannus ingrowth are also issues that need to be resolved.

  8. Ball motion and sliding friction in an arched outer race ball bearing

    NASA Technical Reports Server (NTRS)

    Hamrock, B. J.

    1973-01-01

    The motion of the ball and sliding friction in an arched outer race ball bearing under thrust loads is determined. Fatigue life evaluations were made. The analysis is applied to a 150 millimeter bore ball bearing. The results indicated that for high speed-light load applications the arched bearing has significant improvement in fatigue life over that of a conventional bearing. An arching of 0.254 mm (0.01 in.) was found to be an optimal. For an arched bearing it was also found that a considerable amount of spinning occurs at the outer race contacts.

  9. Ball motion and sliding friction in an arched outer-race ball bearing

    NASA Technical Reports Server (NTRS)

    Hamrock, B. J.

    1974-01-01

    The motion of the ball and sliding friction in an arched outer-race ball bearing under thrust load is analyzed. Fatigue life evaluations were made. The analysis is applied to a 150-millimeter-bore ball bearing. The results indicated that for high-speed light-load applications the arched bearing has significant improvement in fatigue life over that of a conventional bearing. An arching of 0.254 mm (0.01 in.) was found to be optimal. Also, for an arched bearing a considerable amount of spinning occurs at the outer-race contacts.

  10. Self-Rupturing Hermetic Valve

    NASA Technical Reports Server (NTRS)

    Tucker, Curtis E., Jr.; Sherrit, Stewart

    2011-01-01

    For commercial, military, and aerospace applications, low-cost, small, reliable, and lightweight gas and liquid hermetically sealed valves with post initiation on/off capability are highly desirable for pressurized systems. Applications include remote fire suppression, single-use system-pressurization systems, spacecraft propellant systems, and in situ instruments. Current pyrotechnic- activated rupture disk hermetic valves were designed for physically larger systems and are heavy and integrate poorly with portable equipment, aircraft, and small spacecraft and instrument systems. Additionally, current pyrotechnically activated systems impart high g-force shock loads to surrounding components and structures, which increase the risk of damage and can require additional mitigation. The disclosed mechanism addresses the need for producing a hermetically sealed micro-isolation valve for low and high pressure for commercial, aerospace, and spacecraft applications. High-precision electrical discharge machining (EDM) parts allow for the machining of mated parts with gaps less than a thousandth of an inch. These high-precision parts are used to support against pressure and extrusion, a thin hermetically welded diaphragm. This diaphragm ruptures from a pressure differential when the support is removed and/or when the plunger is forced against the diaphragm. With the addition of conventional seals to the plunger and a two-way actuator, a derivative of this design would allow nonhermetic use as an on/off or metering valve after the initial rupturing of the hermetic sealing disk. In addition, in a single-use hermetically sealed isolation valve, the valve can be activated without the use of potential leak-inducing valve body penetrations. One implementation of this technology is a high-pressure, high-flow-rate rupture valve that is self-rupturing, which is advantageous for high-pressure applications such as gas isolation valves. Once initiated, this technology is self

  11. Giant Thoracic Aneurysm Following Valve Replacement for Bicuspid Aortic Valve.

    PubMed

    Tran, Cao; Ul Haq, Ehtesham; Nguyen, Ngoc; Omar, Bassam

    2015-01-01

    Bicuspid aortic valve is a common congenital anomaly associated with aortopathy, which can cause aortic root dilatation, necessitating regular screening if the aortic root is > 4.0 cm. Despite the low absolute incidence of aortic complications associated with bicuspid aortic valve in the general population, the consequences of such complications for an individual patient can be devastating. Herein we propose a balanced algorithm that incorporates recommendations from the three major guidelines for follow-up imaging of the aortic root and ascending thoracic aorta in patients with a bicuspid aortic valve, maintaining the current recommendations with regard to surgical thresholds. PMID:26827748

  12. Transcatheter aortic valve implantation in bicuspid aortic valve stenosis.

    PubMed

    Perlman, Gidon Y; Blanke, Philipp; Webb, John G

    2016-09-18

    Bicuspid aortic stenosis (AS) is not rare in patients treated with transcatheter aortic valve implantation (TAVI). Bicuspid valves have unique anatomy which could affect the results of TAVI; however, multiple recent reports have shown that TAVI is safe and effective in this population. Paravalvular aortic regurgitation was initially found to be more frequent in bicuspid patients, but newer-generation devices have shown superior results in this respect. Higher rates of pacemaker implantation after TAVI in bicuspid AS do require further investigation. Current data suggest that bicuspid valves should not be a contraindication for TAVI, but future specific trials are needed to support this assertion. PMID:27640030

  13. Levitation of an iron ball in midair without active control

    NASA Astrophysics Data System (ADS)

    Sasaki, S.; Yagi, I.; Murakami, M.

    2004-02-01

    An iron ball floats in midair in a plastic box when several iron balls were attracted by a permanent magnet. A complex interaction between magnetized sphere materials and a lifting magnet enabled the suspension of an iron ball. The balls in the first row are simply attracted by the lifting magnet. The ball in the second row is also attracted by the lifting magnet, however, due to the repulsive forces exerted from the balls sitting above, it can float in midair. We also found that there are two stable positions for the ball to float. The floating ball could be transported from one equilibrium position to another by simply rotating the lifting magnet. This will make it possible to construct a noncontact load transport device.

  14. A Momentum Transfer Demonstration with "Happy/Unhappy" Balls.

    ERIC Educational Resources Information Center

    Bucheit, Fred

    1994-01-01

    Describes a simple setup and procedure that uses "happy/unhappy" balls (two balls with different degrees of elasticity) to lead students into a discussion of momentum transfer involving elastic and inelastic collisions. (ZWH)

  15. Tennis ball fuzziness: assessing textile surface roughness using digital imaging

    NASA Astrophysics Data System (ADS)

    Steele, C.; Jones, R.; Leaney, P. G.

    2006-06-01

    Wear plays an important role in the game of tennis as it affects both ball performance and player perceived ball quality. Visual appearance can be used in ball differentiation, but has so far been limited to subjective assessments used to estimate ball wear and performance characteristics. A metric for ball surface condition will allow performance and perception data from varied testing set-ups to be objectively compared and analysed. A versatile new method of assessing surface roughness using digital imaging has been developed to allow the quantitative assessment of tennis ball condition. This metric allows manufacturers and researchers to predict ball performance and player perception from worn ball samples, developing acceptable wear limits. In the successful implementation of this metric, several key factors, including lighting, image thresholding, algorithm implementation and camera specifications, were identified to aid future alternative implementations.

  16. Minimally invasive aortic valve surgery

    PubMed Central

    Castrovinci, Sebastiano; Emmanuel, Sam; Moscarelli, Marco; Murana, Giacomo; Caccamo, Giuseppa; Bertolino, Emanuela Clara; Nasso, Giuseppe; Speziale, Giuseppe; Fattouch, Khalil

    2016-01-01

    Aortic valve disease is a prevalent disorder that affects approximately 2% of the general adult population. Surgical aortic valve replacement is the gold standard treatment for symptomatic patients. This treatment has demonstrably proven to be both safe and effective. Over the last few decades, in an attempt to reduce surgical trauma, different minimally invasive approaches for aortic valve replacement have been developed and are now being increasingly utilized. A narrative review of the literature was carried out to describe the surgical techniques for minimally invasive aortic valve surgery and report the results from different experienced centers. Minimally invasive aortic valve replacement is associated with low perioperative morbidity, mortality and a low conversion rate to full sternotomy. Long-term survival appears to be at least comparable to that reported for conventional full sternotomy. Minimally invasive aortic valve surgery, either with a partial upper sternotomy or a right anterior minithoracotomy provides early- and long-term benefits. Given these benefits, it may be considered the standard of care for isolated aortic valve disease. PMID:27582764

  17. Flow Sizing the Cryosystem Valves

    SciTech Connect

    Kurita, C.H.; /Fermilab

    1989-01-19

    The liquid argon dewar and the three cryostats which contain the modules of the D-Zero detector are cooled and maintained at a low pressure equilibrium by the use of liquid nitrogen cooling loops. The dewar has one vacuum jacketed valve at the inlet of the cooling loop and one at the outlet. Each cryostat has two inlet valves, one for the cooldown loops and one for the operating loops. in addition to an outlet valve. The flow rate of the liquid nitrogen, and hence the valve sizes and corresponding flow coefficients (C{sub v}), is deter mined by the required cooling rate of each system. The large variance between the cooling rate required for cooldown and that required for operation, and the high control resolution required, makes the selection of a valve seat and plug difficult. The liquid valve coefficient calculations do not specifically consider the size affect of gas generated within the valve by adiabatic pressure drop. See Appendix I for a calculation of the magnitude of this effect. The figures and a graphical and tabular summary of the papers conclusions are presented in Appendix II.

  18. Valve for controlling solids flow

    DOEpatents

    Feldman, David K.

    1980-01-01

    A fluidized solids control valve is disclosed that is particularly well adapted for use with a flow of coal or char that includes both large particles and fines. The particles may or may not be fluidized at various times during the operation. The valve includes a tubular body that terminates in a valve seat covered by a normally closed closure plate. The valve body at the seat and the closure plate is provided with aligned longitudinal slots that receive a pivotally supported key plate. The key plate is positionable by an operator in inserted, intermediate and retracted positions respecting the longitudinal slot in the valve body. The key plate normally closes the slot within the closure plate but is shaped and aligned obliquely to the longitudinal slot within the valve body to provide progressively increasing slot openings between the inserted and retracted positions. Transfer members are provided between the operator, key plate and closure plate to move the closure plate into an open position only when the key plate is retracted from the longitudinal slot within the valve body.

  19. Minimally invasive aortic valve surgery.

    PubMed

    Castrovinci, Sebastiano; Emmanuel, Sam; Moscarelli, Marco; Murana, Giacomo; Caccamo, Giuseppa; Bertolino, Emanuela Clara; Nasso, Giuseppe; Speziale, Giuseppe; Fattouch, Khalil

    2016-09-01

    Aortic valve disease is a prevalent disorder that affects approximately 2% of the general adult population. Surgical aortic valve replacement is the gold standard treatment for symptomatic patients. This treatment has demonstrably proven to be both safe and effective. Over the last few decades, in an attempt to reduce surgical trauma, different minimally invasive approaches for aortic valve replacement have been developed and are now being increasingly utilized. A narrative review of the literature was carried out to describe the surgical techniques for minimally invasive aortic valve surgery and report the results from different experienced centers. Minimally invasive aortic valve replacement is associated with low perioperative morbidity, mortality and a low conversion rate to full sternotomy. Long-term survival appears to be at least comparable to that reported for conventional full sternotomy. Minimally invasive aortic valve surgery, either with a partial upper sternotomy or a right anterior minithoracotomy provides early- and long-term benefits. Given these benefits, it may be considered the standard of care for isolated aortic valve disease. PMID:27582764

  20. Cavitation guide for control valves

    SciTech Connect

    Tullis, J.P.

    1993-04-01

    This guide teaches the basic fundamentals of cavitation to provide the reader with an understanding of what causes cavitation, when it occurs, and the potential problems cavitation can cause to a valve and piping system. The document provides guidelines for understanding how to reduce the cavitation and/or select control valves for a cavitating system. The guide provides a method for predicting the cavitation intensity of control valves, and how the effect of cavitation on a system will vary with valve type, valve function, valve size, operating pressure, duration of operation and details of the piping installation. The guide defines six cavitation limits identifying cavitation intensities ranging from inception to the maximum intensity possible. The intensity of the cavitation at each limit Is described, including a brief discussion of how each level of cavitation influences the valve and system. Examples are included to demonstrate how to apply the method, including making both size and pressure scale effects corrections. Methods of controlling cavitation are discussed providing information on various techniques which can be used to design a new system or modify an existing one so it can operate at a desired level of cavitation.

  1. Calibration of industrial CT using two forest-balls

    NASA Astrophysics Data System (ADS)

    Shi, Yushu; Song, Xu; Li, Shi; Li, Wei; Li, Qi; Chen, Siwen; Shen, Fei; Song, Xiaoping; Gao, Sitian

    2015-02-01

    A small forest-ball was manufactured and calibrated using CMM F25. An industrial CT called Metrotom1500 was calibrated by the small forest-ball and another big forest-ball produced by Carl Zeiss. These two forest-balls were separately measured at two different magnifications of the industrial CT, and the measurement results could meet the maximum permissible error of Metrotom1500.

  2. 42 CFR 84.137 - Inhalation and exhalation valves; check valves; minimum requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Inhalation and exhalation valves; check valves... PROTECTIVE DEVICES Supplied-Air Respirators § 84.137 Inhalation and exhalation valves; check valves; minimum requirements. (a) Inhalation and exhalation valves shall be provided where necessary and protected...

  3. 42 CFR 84.137 - Inhalation and exhalation valves; check valves; minimum requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Inhalation and exhalation valves; check valves... PROTECTIVE DEVICES Supplied-Air Respirators § 84.137 Inhalation and exhalation valves; check valves; minimum requirements. (a) Inhalation and exhalation valves shall be provided where necessary and protected...

  4. 49 CFR 192.145 - Valves.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Valves. 192.145 Section 192.145 Transportation... BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Design of Pipeline Components § 192.145 Valves. (a) Except for cast iron and plastic valves, each valve must meet the minimum requirements of API...

  5. 14 CFR 125.137 - Oil valves.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Oil valves. 125.137 Section 125.137....137 Oil valves. (a) Each oil valve must— (1) Comply with § 125.155; (2) Have positive stops or... the valve. (b) The closing of an oil shutoff means must not prevent feathering the propeller,...

  6. 49 CFR 195.420 - Valve maintenance.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Valve maintenance. 195.420 Section 195.420... PIPELINE Operation and Maintenance § 195.420 Valve maintenance. (a) Each operator shall maintain each valve..., inspect each mainline valve to determine that it is functioning properly. (c) Each operator shall...

  7. 14 CFR 125.137 - Oil valves.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Oil valves. 125.137 Section 125.137....137 Oil valves. (a) Each oil valve must— (1) Comply with § 125.155; (2) Have positive stops or... the valve. (b) The closing of an oil shutoff means must not prevent feathering the propeller,...

  8. 14 CFR 125.133 - Fuel valves.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Fuel valves. 125.133 Section 125.133....133 Fuel valves. Each fuel valve must— (a) Comply with § 125.155; (b) Have positive stops or suitable... operation or from accelerated flight conditions are not transmitted to the lines connected to the valve....

  9. 49 CFR 195.260 - Valves: Location.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Valves: Location. 195.260 Section 195.260... PIPELINE Construction § 195.260 Valves: Location. A valve must be installed at each of the following... Administrator finds in a particular case that valves are not justified. (f) On each side of a reservoir...

  10. 14 CFR 125.133 - Fuel valves.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Fuel valves. 125.133 Section 125.133....133 Fuel valves. Each fuel valve must— (a) Comply with § 125.155; (b) Have positive stops or suitable... operation or from accelerated flight conditions are not transmitted to the lines connected to the valve....

  11. 49 CFR 229.109 - Safety valves.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Safety valves. 229.109 Section 229.109....109 Safety valves. Every steam generator shall be equipped with at least two safety valves that have a... allowed working pressure. The safety valves shall be independently connected to the separator and...

  12. 49 CFR 195.420 - Valve maintenance.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Valve maintenance. 195.420 Section 195.420... PIPELINE Operation and Maintenance § 195.420 Valve maintenance. (a) Each operator shall maintain each valve..., inspect each mainline valve to determine that it is functioning properly. (c) Each operator shall...

  13. 49 CFR 229.109 - Safety valves.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Safety valves. 229.109 Section 229.109....109 Safety valves. Every steam generator shall be equipped with at least two safety valves that have a... allowed working pressure. The safety valves shall be independently connected to the separator and...

  14. 49 CFR 192.145 - Valves.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Valves. 192.145 Section 192.145 Transportation... BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Design of Pipeline Components § 192.145 Valves. (a) Except for cast iron and plastic valves, each valve must meet the minimum requirements of API...

  15. 21 CFR 868.5870 - Nonrebreathing valve.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5870 Nonrebreathing valve. (a) Identification. A nonrebreathing valve is a one-way valve that directs breathing gas flow to the patient and... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nonrebreathing valve. 868.5870 Section...

  16. 49 CFR 195.116 - Valves.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Valves. 195.116 Section 195.116 Transportation... PIPELINE Design Requirements § 195.116 Valves. Each valve installed in a pipeline system must comply with the following: (a) The valve must be of a sound engineering design. (b) Materials subject to...

  17. 49 CFR 195.116 - Valves.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Valves. 195.116 Section 195.116 Transportation... PIPELINE Design Requirements § 195.116 Valves. Each valve installed in a pipeline system must comply with the following: (a) The valve must be of a sound engineering design. (b) Materials subject to...

  18. 21 CFR 868.5870 - Nonrebreathing valve.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5870 Nonrebreathing valve. (a) Identification. A nonrebreathing valve is a one-way valve that directs breathing gas flow to the patient and... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Nonrebreathing valve. 868.5870 Section...

  19. 14 CFR 125.137 - Oil valves.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Oil valves. 125.137 Section 125.137....137 Oil valves. (a) Each oil valve must— (1) Comply with § 125.155; (2) Have positive stops or... the valve. (b) The closing of an oil shutoff means must not prevent feathering the propeller,...

  20. 14 CFR 125.137 - Oil valves.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Oil valves. 125.137 Section 125.137....137 Oil valves. (a) Each oil valve must— (1) Comply with § 125.155; (2) Have positive stops or... the valve. (b) The closing of an oil shutoff means must not prevent feathering the propeller,...

  1. 14 CFR 125.137 - Oil valves.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Oil valves. 125.137 Section 125.137....137 Oil valves. (a) Each oil valve must— (1) Comply with § 125.155; (2) Have positive stops or... the valve. (b) The closing of an oil shutoff means must not prevent feathering the propeller,...

  2. 49 CFR 192.145 - Valves.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... following: (1) The valve must have a maximum service pressure rating for temperatures that equal or exceed... percent of the pressure ratings for comparable steel valves at their listed temperature. However, a valve... performance level. A valve may not be used under operating conditions that exceed the applicable...

  3. Computed Tomography Analysis of NASA BSTRA Balls

    SciTech Connect

    Perry, R L; Schneberk, D J; Thompson, R R

    2004-10-12

    Fifteen 1.25 inch BSTRA balls were scanned with the high energy computed tomography system at LLNL. This system has a resolution limit of approximately 210 microns. A threshold of 238 microns (two voxels) was used, and no anomalies at or greater than this were observed.

  4. Spherical polytropic balls cannot mimic black holes

    NASA Astrophysics Data System (ADS)

    Saida, Hiromi; Fujisawa, Atsuhito; Yoo, Chul-Moon; Nambu, Yasusada

    2016-04-01

    The so-called black hole shadow is a dark region which is expected to appear in a fine image of optical observation of black holes. It is essentially an absorption cross section of the black hole, and the boundary of shadow is determined by unstable circular orbits of photons (UCOP). If there exists a compact object possessing UCOP but no black hole horizon, it can provide us with the same shadow image as black holes, and detection of a shadow image cannot be direct evidence of black hole existence. This paper examines whether or not such compact objects can exist under some suitable conditions. We investigate thoroughly the static spherical polytropic ball of perfect fluid with single polytrope index, and then investigate a representative example of a piecewise polytropic ball. Our result is that the spherical polytropic ball which we have investigated cannot possess UCOP, if the speed of sound at the center is subluminal (slower than light). This means that, if the polytrope treated in this paper is a good model of stellar matter in compact objects, the detection of a shadow image can be regarded as good evidence of black hole existence. As a by-product, we have found the upper bound of the mass-to-radius ratio of a polytropic ball with single index, M_{ast }/R_{ast } < 0.281, under the condition of subluminal sound speed.

  5. Introducing a High Bounce Ball Unit

    ERIC Educational Resources Information Center

    Bernardo, Pat

    2004-01-01

    Those growing up in the 1950s, 60s or 70s are familiar with how physically active children were before computers and video games were introduced. Each neighborhood had its own version of the various games that were played. Many of these games involved a pink rubber ball called a Spaldeen. They were everywhere and almost everyone had one. These…

  6. Exploring the Mathematics of Bouncing Balls

    ERIC Educational Resources Information Center

    Vinogradova, Natalya; Blaine, Larry G.

    2010-01-01

    A common textbook problem asks students to calculate the total distance traveled by a bouncing ball, from its initial release until it comes to rest, under the assumption that the height of each bounce is some fixed proportion "r" of the height of the previous bounce. The solution is found by inserting information about "r" and the height from…

  7. Heat-balling wasps by honeybees

    NASA Astrophysics Data System (ADS)

    Ken, Tan; Hepburn, H. R.; Radloff, S. E.; Yusheng, Yu; Yiqiu, Liu; Danyin, Zhou; Neumann, P.

    2005-10-01

    Defensiveness of honeybee colonies of Apis cerana and Apis mellifera (actively balling the wasps but reduction of foraging) against predatory wasps, Vespa velutina, and false wasps was assessed. There were significantly more worker bees in balls of the former than latter. Core temperatures in a ball around a live wasp of A. cerana were significantly higher than those of A. mellifera, and also significantly more when exposed to false wasps. Core temperatures of bee balls exposed to false wasps were significantly lower than those exposed to V. velutina for both A. cerana and for A. mellifera. The lethal thermal limits for V. velutina, A. cerana and A. mellifera were significantly different, so that both species of honeybees have a thermal safety factor in heat-killing such wasp predators. During wasps attacks at the hives measured at 3, 6 and 12 min, the numbers of Apis cerana cerana and Apis cerana indica bees continuing to forage were significantly reduced with increased wasp attack time. Tropical lowland A. c. indica reduced foraging rates significantly more than the highland A. c. cerana bees; but, there was no significant effect on foraging by A. mellifera. The latency to recovery of honeybee foraging was significantly greater the longer the duration of wasp attacks. The results show remarkable thermal fine-tuning in a co-evolving predator prey relationship.

  8. Department of Natural Resources, Ball State University.

    ERIC Educational Resources Information Center

    Hibbs, Clyde W.

    1987-01-01

    Describes the environmental education programs of Ball State University's Department of Natural Resources. Focusing on natural resource science and technology, the program has thrusts in resource conservation, environmental protection, and environmental education. Outlines the program goals, courses, curricular patterns, graduate programs, and…

  9. 4. pi. physics with the plastic ball

    SciTech Connect

    Gutbrod, H.H.; Loehner, H.; Poskanzer, A.M.; Renner, T.; Riedesel, H.; Ritter, H.G.; Warwick, A.; Weik, F.; Wieman, H.

    1982-10-01

    4 ..pi.. data taken with the Plastic Ball show that cluster production in relativistic nuclear collisions depends on both the size of the participant volume and the finite size of the cluster. The measurement of the degree of thermalization and the search for collective flow will permit the study of the applicability of macroscopic concepts such as temperature and density.

  10. When Two Balls Are Just One

    ERIC Educational Resources Information Center

    Kulp, Christopher W.; Biermann, Mark L.; Howard, Timothy; Klingenberg, Kurtis; Ramsey, Paul

    2008-01-01

    A camcorder can be a powerful tool in pedagogical settings, such as in an introductory physics course or in introducing undergraduates to data collection. In this paper, we discuss our experience using a Panasonic PV-GS150 digital camcorder to analyze the motion of a falling steel ball, with the goal of determining the acceleration due to gravity,…

  11. Construction of the noncommutative complex ball

    SciTech Connect

    Wang, Zhituo

    2014-09-15

    We describe the construction of the noncommutative complex ball whose commutative analog is the Hermitian symmetric space D = SU(m, 1)/U(m), with the method of coherent state quantization. In the commutative limit, we obtain the standard manifold. We also consider a quantum field theory model on the noncommutative manifold.

  12. Two experimental investigations of ball lightning

    NASA Astrophysics Data System (ADS)

    Alexeff, Igor; Parameswaran, Sriram; Grace, Michael

    2004-11-01

    We have carried out two experiments that appear to produce ball lightning in the laboratory. The first set of observations were made at the Holifield high voltage accelerator at the Oak Ridge National Laboratory (1). In these experiments at very high voltage, closed current loops were photographed in high voltage sparkovers. These may be current loops sustained by the enclosed magnetic field. In the second set of experiments, a pulsed electric arc in a zero - gravity environment produced orange balls in atmospheric - pressure air that persisted for over 1/2 second after power turn - off (2). These balls were photographed with a high - speed 16 mm movie camera. Photos and movies of these experiments will be presented. 1. "Observation of Closed Loops in High-Voltage Discharges: A Possible Precursor of Magnetic Flux Trapping", Igor Alexeff and Mark Rader, IEEE Transactions on Plasma Science, Vol. 20, No. 6, December 1992, pp.669 - 671: ``Possible Precursors of Ball Lightning--Observation of Closed Loops in High- Voltage Discharges,'' Igor Alexeff and Mark Rader, Fusion Technology, Vol. 27, May 1995, pp 271 - 273 2. I. Alexeff et. al., Invited paper at The International Conference on Plasma Science, Preceedings of the Conference, Baltimore, Md., June 2004.

  13. The dynamic behavior of squash balls

    NASA Astrophysics Data System (ADS)

    Lewis, Gareth J.; Arnold, J. Cris; Griffiths, Iwan W.

    2011-03-01

    The behavior of a squash ball constitutes an excellent case study of the dynamic behavior of rubbery materials. It is shown that the complex viscoelastic behavior of rubber can be investigated using simple drop bounce tests and compression tests. The drop tests show that the coefficient of restitution increases as the ball temperature increases. The compression tests show that as the speed of compression increases or as the ball temperature decreases, the compressive force and the energy loss both increase. These effects are due to the viscoelastic nature of the rubber and are an excellent example of the time-temperature equivalence of polymers. Compression tests were performed on balls with small holes at the base to separate the effects of the internal air pressure from the material deformation. It was found that the internal air pressure contributed about one-third to the compressive force, but contributed little to energy loss. This behavior shows that the rubber material dominates the rebound behavior and that the normal warming up process at the start of a squash game is important to raise the temperature of the rubber rather than to increase the internal air pressure.

  14. Sharpening ball-nose mill cutters

    NASA Technical Reports Server (NTRS)

    Burch, C. F.

    1977-01-01

    Economical attachment allows faster, more precise grinding. Vibrationless and rigid relation between grinding wheel and cutter allows for extremely high finish and accurate grinding. Leveling device levels flutes with respect to toolholder rotation that generates ball-nose radius. Constant relief around entire profile of cutting edge produces longer tool life.

  15. Fractal Aggregates in Tennis Ball Systems

    ERIC Educational Resources Information Center

    Sabin, J.; Bandin, M.; Prieto, G.; Sarmiento, F.

    2009-01-01

    We present a new practical exercise to explain the mechanisms of aggregation of some colloids which are otherwise not easy to understand. We have used tennis balls to simulate, in a visual way, the aggregation of colloids under reaction-limited colloid aggregation (RLCA) and diffusion-limited colloid aggregation (DLCA) regimes. We have used the…

  16. Crystal Ball results on tau decays

    SciTech Connect

    Lowe, S.T.

    1987-10-01

    This report reviews measurements and upper limit determinations for a number of exclusive 1-prong tau decay modes using the Crystal Ball detector. These results are important input to the apparent discrepancy between the topological and sum-of-exclusive branching fractions in 1-prong tau decays.

  17. Recent results from the Crystal Ball experiment

    SciTech Connect

    Lowe, S.T.

    1986-12-01

    Several recent analyses from the Crystal Ball collaboration are reviewed. The major topics discussed are the search for new states in radiative UPSILON(1S) decays, the search for lepton number-violating and inclusive eta decay modes of the tau, and results from ..gamma gamma.. physics.

  18. Thermostatic Radiator Valve Evaluation

    SciTech Connect

    Dentz, J.; Ansanelli, E.

    2015-01-01

    A large stock of multifamily buildings in the Northeast and Midwest are heated by steam distribution systems. Losses from these systems are typically high and a significant number of apartments are overheated much of the time. Thermostatically controlled radiator valves (TRVs) are one potential strategy to combat this problem, but have not been widely accepted by the residential retrofit market. In this project, the ARIES team sought to better understand the current usage of TRVs by key market players in steam and hot water heating and to conduct limited experiments on the effectiveness of new and old TRVs as a means of controlling space temperatures and reducing heating fuel consumption. The project included a survey of industry professionals, a field experiment comparing old and new TRVs, and cost-benefit modeling analysis using BEopt™ (Building Energy Optimization software).

  19. Multi-port valve

    DOEpatents

    Lewin, Keith F.

    1997-04-15

    A multi-port valve for regulating, as a function of ambient air having varying wind velocity and wind direction in an open-field control area, the distribution of a fluid, particularly carbon dioxide (CO.sub.2) gas, in a fluid distribution system so that the control area remains generally at an elevated fluid concentration or level of said fluid. The multi-port valve generally includes a multi-port housing having a plurality of outlets therethrough disposed in a first pattern of outlets and at least one second pattern of outlets, and a movable plate having a plurality of apertures extending therethrough disposed in a first pattern of apertures and at least one second pattern of apertures. The first pattern of apertures being alignable with the first pattern of outlets and the at least one second pattern of apertures being alignable with the second pattern of outlets. The first pattern of apertures has a predetermined orientation with the at least one second pattern of apertures. For an open-field control area subject to ambient wind having a low velocity from any direction, the movable plate is positioned to equally distribute the supply of fluid in a fluid distribution system to the open-field control area. For an open-field control area subject to ambient wind having a high velocity from a given direction, the movable plate is positioned to generally distribute a supply of fluid in a fluid distribution system to that portion of the open-field control area located upwind.

  20. Multi-port valve

    DOEpatents

    Lewin, K.F.

    1997-04-15

    A multi-port valve is described for regulating, as a function of ambient air having varying wind velocity and wind direction in an open-field control area, the distribution of a fluid, particularly carbon dioxide (CO{sub 2}) gas, in a fluid distribution system so that the control area remains generally at an elevated fluid concentration or level of said fluid. The multi-port valve generally includes a multi-port housing having a plurality of outlets there through disposed in a first pattern of outlets and at least one second pattern of outlets, and a movable plate having a plurality of apertures extending there through disposed in a first pattern of apertures and at least one second pattern of apertures. The first pattern of apertures being alignable with the first pattern of outlets and the at least one second pattern of apertures being alignable with the second pattern of outlets. The first pattern of apertures has a predetermined orientation with the at least one second pattern of apertures. For an open-field control area subject to ambient wind having a low velocity from any direction, the movable plate is positioned to equally distribute the supply of fluid in a fluid distribution system to the open-field control area. For an open-field control area subject to ambient wind having a high velocity from a given direction, the movable plate is positioned to generally distribute a supply of fluid in a fluid distribution system to that portion of the open-field control area located upwind. 7 figs.