Sample records for static analysis alerts

  1. Static Analysis Alert Audits: Lexicon and Rules

    DTIC Science & Technology

    2016-11-04

    collaborators • Includes a standard set of well-defined determinations for static analysis alerts • Includes a set of auditing rules to help auditors make...consistent decisions in commonly-encountered situations Different auditors should make the same determination for a given alert! Improve the quality and...scenarios • Establish assumptions auditors can make • Overall: help make audit determinations more consistent We developed 12 rules • Drew on our own

  2. Vestibular afferent responses to linear accelerations in the alert squirrel monkey

    NASA Technical Reports Server (NTRS)

    Somps, Christopher J.; Schor, Robert H.; Tomko, David L.

    1994-01-01

    The spontaneous activity of 40 otolith afferents and 44 canal afferents was recorded in 4 alert, intact squirrel monkeys. Polarization vectors and response properties of otolith afferents were determined during static re-orientations relative to gravity and during Earth-horizontal, sinusoidal, linear oscillations. Canal afferents were tested for sensitivity to linear accelerations. For regular otolith afferents, a significant correlation between upright discharge rate and sensitivity to dynamic acceleration in the horizontal plane was observed. This correlation was not present in irregular units. The sensitivity of otolith afferents to both static tilts and dynamic linear acceleration was much greater in irregularly discharging units than in regularly discharging units. The spontaneous activity and static and dynamic response properties of regularly discharging otolith afferents were similar to those reported in barbiturate-anesthetized squirrel monkeys. Irregular afferents also had similar dynamic response properties when compared to anesthetized monkeys. However, this sample of irregular afferents in alert animals had higher resting discharge rates and greater sensitivity to static tilts. The majority of otolith polarization vectors were oriented near the horizontal in the plane of the utricular maculae; however, directions of maximum sensitivity were different during dynamic and static testing. Canal afferents were not sensitive to static tilts or linear oscillations of the head.

  3. CAUSE Resiliency (West Coast) Experiment Final Report

    DTIC Science & Technology

    2012-10-01

    implemented in BCeMap and can therefore consume alerting messages direct from MASAS. This would solve the issue with the update frequency and speed of the...in production for use by the Provincial Emergency Operations Centres and brings together multiple static layers together with several dynamic data...executive order established the requirement for an “effective, reliable, integrated, flexible, and comprehensive system to alert and warn the

  4. Hazards in Motion: Development of Mobile Geofences for Use in Logging Safety

    PubMed Central

    Zimbelman, Eloise G.; Keefe, Robert F.; Strand, Eva K.; Kolden, Crystal A.; Wempe, Ann M.

    2017-01-01

    Logging is one of the most hazardous occupations in the United States. Real-time positioning that uses global navigation satellite system (GNSS) technology paired with radio frequency transmission (GNSS-RF) has the potential to reduce fatal and non-fatal accidents on logging operations through the use of geofences that define safe work areas. Until recently, most geofences have been static boundaries. The aim of this study was to evaluate factors affecting mobile geofence accuracy in order to determine whether virtual safety zones around moving ground workers or equipment are a viable option for improving situational awareness on active timber sales. We evaluated the effects of walking pace, transmission interval, geofence radius, and intersection angle on geofence alert delay using a replicated field experiment. Simulation was then used to validate field results and calculate the proportion of GNSS error bearings resulting in early alerts. The interaction of geofence radius and intersection angle affected safety geofence alert delay in the field experiment. The most inaccurate alerts were negative, representing early warning. The magnitude of this effect was largest at the greatest intersection angles. Simulation analysis supported these field results and also showed that larger GNSS error corresponded to greater variability in alert delay. Increasing intersection angle resulted in a larger proportion of directional GNSS error that triggered incorrect, early warnings. Because the accuracy of geofence alerts varied greatly depending on GNSS error and angle of approach, geofencing for occupational safety is most appropriate for general situational awareness unless real-time correction methods to improve accuracy or higher quality GNSS-RF transponders are used. PMID:28394303

  5. Successful Outcomes of a Clinical Decision Support System in an HIV Practice: A Randomized Controlled Trial

    PubMed Central

    Robbins, Gregory K.; Lester, William; Johnson, Kristin L.; Chang, Yuchiao; Estey, Gregory; Surrao, Dominic; Zachary, Kimon; Lammert, Sara M.; Chueh, Henry; Meigs, James B.; Freedberg, Kenneth A.

    2013-01-01

    Background Data to support improved patient outcomes from clinical decision support systems (CDSS) are lacking in HIV care. Objective To conduct a randomized controlled trial testing the efficacy of a CDSS to improve HIV outcomes in an outpatient clinic. Design We conducted a randomized controlled trial where half of each provider’s patients were randomized to interactive or static computer alerts (ClinicalTrials.gov #NCT00678600). Setting The study was conducted at the Massachusetts General Hospital HIV Clinic. Subjects Participants were HIV providers and their HIV-infected patients. Intervention Computer alerts were generated for virologic failure (HIV RNA >400 c/mL after HIV RNA ≤400 c/mL), evidence of suboptimal follow-up, and 11 abnormal laboratory tests. Providers received interactive computer alerts, facilitating appointment rescheduling and repeat laboratory testing, for half of their patients and static alerts for the other half. Measurements The primary endpoint was change in CD4 count. Other endpoints included time-to-clinical event, 6-month suboptimal follow-up, and severe laboratory toxicity. Results Thirty-three HIV providers followed 1,011 HIV-infected patients. For the intervention arm, the mean CD4 count increase was greater (5.3 versus 3.2 cells/mm3/month; difference = 2.0 cells/mm3/month 95% CI [0.1, 4.0], p=0.040) and the rate of 6-month suboptimal follow-up was lower (20.6 versus 30.1 events per 100 patient-years, p=0.022). Median time-to-next scheduled appointment was shorter in the intervention arm after a suboptimal follow-up alert (1.71 versus 3.48 months; p<0.001) and after a toxicity alert (2.79 versus >6 months for control); p=0.072). Ninety-six percent of providers supported adopting the CDSS as part of standard care. Limitations This was a one-year informatics study conducted at a single hospital sub-specialty clinic. Conclusion A CDSS using interactive provider alerts improved CD4 counts and clinic follow-up for HIV-infected patients. Wider implementation of such systems can provide important clinical benefits. PMID:23208165

  6. Voltage Sensors Monitor Harmful Static

    NASA Technical Reports Server (NTRS)

    2009-01-01

    A tiny sensor, small enough to be worn on clothing, now monitors voltage changes near sensitive instruments after being created to alert Agency workers to dangerous static buildup near fuel operations and avionics. San Diego s Quasar Federal Systems received a Small Business Innovation Research (SBIR) contract from Kennedy Space Center to develop its remote voltage sensor (RVS), a dime-sized electrometer designed to measure triboelectric changes in the environment. One of the unique qualities of the RVS is that it can detect static at greater distances than previous devices, measuring voltage changes from a few centimeters to a few meters away, due to its much-improved sensitivity.

  7. The Emerging Infrastructure of Autonomous Astronomy

    NASA Astrophysics Data System (ADS)

    Seaman, R.; Allan, A.; Axelrod, T.; Cook, K.; White, R.; Williams, R.

    2007-10-01

    Advances in the understanding of cosmic processes demand that sky transient events be confronted with statistical techniques honed on static phenomena. Time domain data sets require vast surveys such as LSST {http://www.lsst.org/lsst_home.shtml} and Pan-STARRS {http://www.pan-starrs.ifa.hawaii.edu}. A new autonomous infrastructure must close the loop from the scheduling of survey observations, through data archiving and pipeline processing, to the publication of transient event alerts and automated follow-up, and to the easy analysis of resulting data. The IVOA VOEvent {http://voevent.org} working group leads efforts to characterize sky transient alerts published through VOEventNet {http://voeventnet.org}. The Heterogeneous Telescope Networks (HTN {http://www.telescope-networks.org}) consortium are observatories and robotic telescope projects seeking interoperability with a long-term goal of creating an e-market for telescope time. Two projects relying on VOEvent and HTN are eSTAR {http://www.estar.org.uk} and the Thinking Telescope {http://www.thinkingtelescopes.lanl.gov} Project.

  8. 14 CFR 27.173 - Static longitudinal stability.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... control is necessary to obtain an airspeed less than the trim speed, and a forward movement of the control is necessary to obtain an airspeed more than the trim speed. (b) Throughout the full range of... within ±5 knots of the desired trim airspeed without exceptional piloting skill or alertness. [Amdt. 27...

  9. Contributors to Frequent Telehealth Alerts Including False Alerts for Patients with Heart Failure: A Mixed Methods Exploration

    PubMed Central

    Radhakrishna, K.; Bowles, K.; Zettek-Sumner, A.

    2013-01-01

    Summary Background Telehealth data overload through high alert generation is a significant barrier to sustained adoption of telehealth for managing HF patients. Objective To explore the factors contributing to frequent telehealth alerts including false alerts for Medicare heart failure (HF) patients admitted to a home health agency. Materials and Methods A mixed methods design that combined quantitative correlation analysis of patient characteristic data with number of telehealth alerts and qualitative analysis of telehealth and visiting nurses’ notes on follow-up actions to patients’ telehealth alerts was employed. All the quantitative and qualitative data was collected through retrospective review of electronic records of the home heath agency. Results Subjects in the study had a mean age of 83 (SD = 7.6); 56% were female. Patient co-morbidities (p<0.05) of renal disorders, anxiety, and cardiac arrhythmias emerged as predictors of telehealth alerts through quantitative analysis (n = 168) using multiple regression. Inappropriate telehealth measurement technique by patients (54%) and home healthcare system inefficiencies (37%) contributed to most telehealth false alerts in the purposive qualitative sub-sample (n = 35) of patients with high telehealth alerts. Conclusion Encouraging patient engagement with the telehealth process, fostering a collaborative approach among all the clinicians involved with the telehealth intervention, tailoring telehealth alert thresholds to patient characteristics along with establishing patient-centered telehealth outcome goals may allow meaningful generation of telehealth alerts. Reducing avoidable telehealth alerts could vastly improve the efficiency and sustainability of telehealth programs for HF management. PMID:24454576

  10. Wireless Emergency Alerts (WEA) Cybersecurity Risk Management Strategy for Alert Originators

    DTIC Science & Technology

    2014-03-01

    formerly known as the Commercial Mobile Alert Service ( CMAS ) RDT&E program, is a collaborative partnership that includes the cellular industry, the...Examples illustrate a STRIDE analysis of the generic mission 1 The CMAS Alerting Pipeline Taxonomy describes in detail a hierarchical classification...SEI-2013-SR-018 | 1 1 Introduction The Wireless Emergency Alerts (WEA) service, formerly known as the Commercial Mobile Alert Service ( CMAS ), is a

  11. Provider management strategies of abnormal test result alerts: a cognitive task analysis.

    PubMed

    Hysong, Sylvia J; Sawhney, Mona K; Wilson, Lindsay; Sittig, Dean F; Espadas, Donna; Davis, Traber; Singh, Hardeep

    2010-01-01

    Electronic medical records (EMRs) facilitate abnormal test result communication through "alert" notifications. The aim was to evaluate how primary care providers (PCPs) manage alerts related to critical diagnostic test results on their EMR screens, and compare alert-management strategies of providers with high versus low rates of timely follow-up of results. 28 PCPs from a large, tertiary care Veterans Affairs Medical Center (VAMC) were purposively sampled according to their rates of timely follow-up of alerts, determined in a previous study. Using techniques from cognitive task analysis, participants were interviewed about how and when they manage alerts, focusing on four alert-management features to filter, sort and reduce unnecessary alerts on their EMR screens. Provider knowledge of alert-management features ranged between 4% and 75%. Almost half (46%) of providers did not use any of these features, and none used more than two. Providers with higher versus lower rates of timely follow-up used the four features similarly, except one (customizing alert notifications). Providers with low rates of timely follow-up tended to manually scan the alert list and process alerts heuristically using their clinical judgment. Additionally, 46% of providers used at least one workaround strategy to manage alerts. Considerable heterogeneity exists in provider use of alert-management strategies; specific strategies may be associated with lower rates of timely follow-up. Standardization of alert-management strategies including improving provider knowledge of appropriate tools in the EMR to manage alerts could reduce the lack of timely follow-up of abnormal diagnostic test results.

  12. Prescription order risk factors for pediatric dosing alerts.

    PubMed

    Stultz, J S; Porter, K; Nahata, M C

    2015-02-01

    To determine dosing alert rates based on prescription order characteristics and identify prescription order risk factors for the occurrence of dosing alerts. A retrospective analysis of inpatient medication orders and dosing alerts occurring during October 2011 and January, April, and July 2012 at a pediatric institution. Prescription orders and alerts were categorized by: medication class, patient age, route of administration, and month of the year. There were 228,259 orders during the studied period, with 11,072 alerted orders (4.9%). The most frequently alerted medication class was the non-analgesic central nervous system agent class (14% of alerts). Age, route, medication class, and month all independently affected dosing alert rates. The alert rate was highest for immunosuppressive agents (54%), neonates (6.7%), and orders for rectal administration (9.5%). The alert rate was higher in adult patients receiving their care at a pediatric institution (5.7%) compared to children (4.7%), but after multivariate analysis, pediatric orders had higher odds for an alert (OR 1.1, 95% CI 1.05-1.16). Mercaptopurine had the highest alert rate when categorized by active ingredient (73.9%). Albuterol 2.5mg/mL continuous aerosol and heparin 1000 units in 0.9% sodium chloride injection solution were the unique medications with the highest alert rates (100.0% and 97.7%, respectively). Certain types of prescription orders have a higher risk for causing dosing alerts than others. Patient age, medication class, route of administration, and the month of year can affect dosing alert rates. Design and customization efforts should focus on these medications and prescription order characteristics that increase the risk for dosing alerts. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  13. Provider management strategies of abnormal test result alerts: a cognitive task analysis

    PubMed Central

    Sawhney, Mona K; Wilson, Lindsay; Sittig, Dean F; Espadas, Donna; Davis, Traber; Singh, Hardeep

    2010-01-01

    Objective Electronic medical records (EMRs) facilitate abnormal test result communication through “alert” notifications. The aim was to evaluate how primary care providers (PCPs) manage alerts related to critical diagnostic test results on their EMR screens, and compare alert-management strategies of providers with high versus low rates of timely follow-up of results. Design 28 PCPs from a large, tertiary care Veterans Affairs Medical Center (VAMC) were purposively sampled according to their rates of timely follow-up of alerts, determined in a previous study. Using techniques from cognitive task analysis, participants were interviewed about how and when they manage alerts, focusing on four alert-management features to filter, sort and reduce unnecessary alerts on their EMR screens. Results Provider knowledge of alert-management features ranged between 4% and 75%. Almost half (46%) of providers did not use any of these features, and none used more than two. Providers with higher versus lower rates of timely follow-up used the four features similarly, except one (customizing alert notifications). Providers with low rates of timely follow-up tended to manually scan the alert list and process alerts heuristically using their clinical judgment. Additionally, 46% of providers used at least one workaround strategy to manage alerts. Conclusion Considerable heterogeneity exists in provider use of alert-management strategies; specific strategies may be associated with lower rates of timely follow-up. Standardization of alert-management strategies including improving provider knowledge of appropriate tools in the EMR to manage alerts could reduce the lack of timely follow-up of abnormal diagnostic test results. PMID:20064805

  14. Wearable PPG sensor based alertness scoring system.

    PubMed

    Dey, Jishnu; Bhowmik, Tanmoy; Sahoo, Saswata; Tiwari, Vijay Narayan

    2017-07-01

    Quantifying mental alertness in today's world is important as it enables the person to adopt lifestyle changes for better work efficiency. Miniaturized sensors in wearable devices have facilitated detection/monitoring of mental alertness. Photoplethysmography (PPG) sensors through Heart Rate Variability (HRV) offer one such opportunity by providing information about one's daily alertness levels without requiring any manual interference from the user. In this paper, a smartwatch based alertness estimation system is proposed. Data collected from PPG sensor of smartwatch is processed and fed to machine learning based model to get a continuous alertness score. Utility functions are designed based on statistical analysis to give a quality score on different stages of alertness such as awake, long sleep and short duration power nap. An intelligent data collection approach is proposed in collaboration with the motion sensor in the smartwatch to reduce battery drainage. Overall, our proposed wearable based system provides a detailed analysis of alertness over a period in a systematic and optimized manner. We were able to achieve an accuracy of 80.1% for sleep/awake classification along with alertness score. This opens up the possibility for quantifying alertness levels using a single PPG sensor for better management of health related activities including sleep.

  15. Knowledge Integration and Use-Case Analysis for a Customized Drug-Drug Interaction CDS Service

    NASA Astrophysics Data System (ADS)

    Kam, Hye Jin; Park, Man Young; Kim, Woojae; Yoon, Duk Yong; Ahn, Eun Kyoung; Park, Rae Woong

    Clinical decision support systems (CDSSs) are thought to reduce adverse drug events (ADEs) by monitoring drug-drug interactions(DDIs). However, clinically improper or excessive alerts can result in high alert overrides. A tailored CDS service, which is appropriate for clinicians and their ordering situations, is required to increase alert acceptance. In this study, we conducted a 12-week pilot project adopting a tailed CDSS at an emergency department. The new CDSS was conducted via a stepwise integration of additional new rules. The alert status with changes in acceptance rate was analyzed. The most frequent DDI alerts were related to prescriptions of anti-inflammatory drugs. The percentages of alert overrides for each stage were 98.0%, 96.0%, 96.9%, and 98.1%, respectively. 91.5% of overridden alerts were related to discharge medications. To reduce the potential hazards of ADEs, the development of an effective customized DDI CDSS is required, via in-depth analysis on alert patterns and overridden reasons.

  16. Analysis of UAS DAA Alerting in Fast-Time Simulations without DAA Mitigation

    NASA Technical Reports Server (NTRS)

    Thipphavong, David P.; Santiago, Confesor; Isaacson, Douglas R.; Lee, Seung Man; Park, Chunki; Refai, Mohamad Said; Snow, James

    2015-01-01

    Realization of the expected proliferation of Unmanned Aircraft System (UAS) operations in the National Airspace System (NAS) depends on the development and validation of performance standards for UAS Detect and Avoid (DAA) Systems. The RTCA Special Committee 228 is charged with leading the development of draft Minimum Operational Performance Standards (MOPS) for UAS DAA Systems. NASA, as a participating member of RTCA SC-228 is committed to supporting the development and validation of draft requirements for DAA alerting system performance. A recent study conducted using NASA's ACES (Airspace Concept Evaluation System) simulation capability begins to address questions surrounding the development of draft MOPS for DAA alerting systems. ACES simulations were conducted to study the performance of alerting systems proposed by the SC-228 DAA Alerting sub-group. Analysis included but was not limited to: 1) correct alert (and timeliness), 2) false alert (and severity and duration), 3) missed alert, and 4) probability of an alert type at the time of loss of well clear. The performance of DAA alerting systems when using intent vs. dead-reckoning for UAS ownship trajectories was also compared. The results will be used by SC-228 to inform decisions about the surveillance standards of UAS DAA systems and future requirements development and validation efforts.

  17. Improving Conflict Alert Performance Using Moving Target Detector Data.

    DTIC Science & Technology

    1982-06-01

    2 L136 IIIII I lIlS 1 1 10 11120 125 11111I ~1.6 MICROCOPY RESOLUTION TEST CHART NATIONAL BUREAU Of SIANDARDg 19bi A DOT/FAA/RD-82/47 DOT/FAA/CT-81...Differences for Stochastic Case 23 7 Illustration of Scenarios for Warning Time Tests 30 8 Illustration of Scenarios Used for Nuisance Alert 35 Area...Nuisance Alert Area Analysis of Scenario 3 with a Target 64 Velocity of 480 Knots and SPMB= SPPB =2.8 nmi 12 Nuisance Alert Area Analysis of Scenario 3

  18. Emergency vehicle alert system, phase 2

    NASA Technical Reports Server (NTRS)

    Barr, Tom; Harper, Warren; Reed, Bill; Wallace, David

    1993-01-01

    The EVAS provides warning for hearing-impaired motor vehicle drivers that an emergency vehicle is in the local vicinity. Direction and distance to the emergency vehicle are presented visually to the driver. This is accomplished by a special RF transmission/reception system. During this phase the receiver and transmitter from Phase 1 were updated and modified and a directional antenna developed. The system was then field tested with good results. Static and dynamic (moving vehicle) tests were made with the direction determined correctly 98 percent of the time.

  19. Radar-based alert system to operate a sewerage network: relevance and operational effectiveness after several years of use.

    PubMed

    Faure, D; Payrastre, O; Auchet, P

    2005-01-01

    Since January 2000, the sewerage network of a very urbanised catchment area in the Greater Nancy Urban Community has been operated according to the alarms generated in real time by a storm alert system using weather radar data. This alert system is based on an automatic identification of intense rain cells in the radar images. This paper presents the characteristics of this alert system and synthesises the main results of two complementary studies realised in 2002 in order to estimate the relevance and the operational effectiveness of the alert system. The first study consisted in an off-line analysis of almost 50,000 intense rain cells detected in four years of historical radar data. The second study was an analysis of the experience feedback after two years of operational use of this alert system. The results of these studies are discussed in function of the initial operational objectives.

  20. NAS-Wide Fast-Time Simulation Study for Evaluating Performance of UAS Detect-and-Avoid Alerting and Guidance Systems

    NASA Technical Reports Server (NTRS)

    Lee, Seung Man; Park, Chunki; Cone, Andrew Clayton; Thipphavong, David P.; Santiago, Confesor

    2016-01-01

    This presentation contains the analysis results of NAS-wide fast-time simulations with UAS and VFR traffic for a single day for evaluating the performance of Detect-and-Avoid (DAA) alerting and guidance systems. This purpose of this study was to help refine and validate MOPS alerting and guidance requirements. In this study, we generated plots of all performance metrics that are specified by RTCA SC-228 Minimum Operational Performance Standards (MOPS): 1) to evaluate the sensitivity of alerting parameters on the performance metrics of each DAA alert type: Preventive, Corrective, and Warning alerts and 2) to evaluate the effect of sensor uncertainty on DAA alerting and guidance performance.

  1. Stimulated reporting: the impact of US food and drug administration-issued alerts on the adverse event reporting system (FAERS).

    PubMed

    Hoffman, Keith B; Demakas, Andrea R; Dimbil, Mo; Tatonetti, Nicholas P; Erdman, Colin B

    2014-11-01

    The US Food and Drug Administration (FDA) uses the Adverse Event Reporting System (FAERS) to support post-marketing safety surveillance programs. Currently, almost one million case reports are submitted to FAERS each year, making it a vast repository of drug safety information. Sometimes cited as a limitation of FAERS, however, is the assumption that "stimulated reporting" of adverse events (AEs) occurs in response to warnings, alerts, and label changes that are issued by the FDA. To determine the extent of "stimulated reporting" in the modern-day FAERS database. One hundred drugs approved by the FDA between 2001 and 2010 were included in this analysis. FDA alerts were obtained by a comprehensive search of the FDA's MedWatch and main websites. Publicly available FAERS data were used to assess the "primary suspect" AE reporting pattern for up to four quarters before, and after, the issuance of an FDA alert. A few drugs did demonstrate "stimulated reporting" trends. A majority of the drugs, however, showed little evidence for significant reporting changes associated with the issuance of alerts. When we compared the percentage changes in reporting after an FDA alert with those after a sham "control alert", the overall reporting trends appeared to be quite similar. Of 100 drugs analyzed for short-term reporting trends, 21 real alerts and 25 sham alerts demonstrated an increase (greater than or equal to 1 %) in reporting. The long-term analysis of 91 drugs showed that 24 real alerts and 28 sham alerts demonstrated a greater than or equal to 1 % increase. Our results suggest that most of modern day FAERS reporting is not significantly affected by the issuance of FDA alerts.

  2. Bar Code Medication Administration Technology: Characterization of High-Alert Medication Triggers and Clinician Workarounds.

    PubMed

    Miller, Daniel F; Fortier, Christopher R; Garrison, Kelli L

    2011-02-01

    Bar code medication administration (BCMA) technology is gaining acceptance for its ability to prevent medication administration errors. However, studies suggest that improper use of BCMA technology can yield unsatisfactory error prevention and introduction of new potential medication errors. To evaluate the incidence of high-alert medication BCMA triggers and alert types and discuss the type of nursing and pharmacy workarounds occurring with the use of BCMA technology and the electronic medication administration record (eMAR). Medication scanning and override reports from January 1, 2008, through November 30, 2008, for all adult medical/surgical units were retrospectively evaluated for high-alert medication system triggers, alert types, and override reason documentation. An observational study of nursing workarounds on an adult medicine step-down unit was performed and an analysis of potential pharmacy workarounds affecting BCMA and the eMAR was also conducted. Seventeen percent of scanned medications triggered an error alert of which 55% were for high-alert medications. Insulin aspart, NPH insulin, hydromorphone, potassium chloride, and morphine were the top 5 high-alert medications that generated alert messages. Clinician override reasons for alerts were documented in only 23% of administrations. Observational studies assessing for nursing workarounds revealed a median of 3 clinician workarounds per administration. Specific nursing workarounds included a failure to scan medications/patient armband and scanning the bar code once the dosage has been removed from the unit-dose packaging. Analysis of pharmacy order entry process workarounds revealed the potential for missed doses, duplicate doses, and doses being scheduled at the wrong time. BCMA has the potential to prevent high-alert medication errors by alerting clinicians through alert messages. Nursing and pharmacy workarounds can limit the recognition of optimal safety outcomes and therefore workflow processes must be continually analyzed and restructured to yield the intended full benefits of BCMA technology. © 2011 SAGE Publications.

  3. Comparative Analysis of ACAS-Xu and DAIDALUS Detect-and-Avoid Systems

    NASA Technical Reports Server (NTRS)

    Davies, Jason T.; Wu, Minghong G.

    2018-01-01

    The Detect and Avoid (DAA) capability of a recent version (Run 3) of the Airborne Collision Avoidance System-Xu (ACAS-Xu) is measured against that of the Detect and AvoID Alerting Logic for Unmanned Systems (DAIDALUS), a reference algorithm for the Phase 1 Minimum Operational Performance Standards (MOPS) for DAA. This comparative analysis of the two systems' alerting and horizontal guidance outcomes is conducted through the lens of the Detect and Avoid mission using flight data of scripted encounters from a recent flight test. Results indicate comparable timelines and outcomes between ACAS-Xu's Remain Well Clear alert and guidance and DAIDALUS's corrective alert and guidance, although ACAS-Xu's guidance appears to be more conservative. ACAS-Xu's Collision Avoidance alert and guidance occurs later than DAIDALUS's warning alert and guidance, and overlaps with DAIDALUS's timeline of maneuver to remain Well Clear. Interesting discrepancies between ACAS-Xu's directive guidance and DAIDALUS's "Regain Well Clear" guidance occur in some scenarios.

  4. Impact of e-alert for detection of acute kidney injury on processes of care and outcomes: protocol for a systematic review and meta-analysis.

    PubMed

    Lachance, Philippe; Villeneuve, Pierre-Marc; Wilson, Francis P; Selby, Nicholas M; Featherstone, Robin; Rewa, Oleksa; Bagshaw, Sean M

    2016-05-05

    Acute kidney injury (AKI) is a common complication in hospitalised patients. It imposes significant risk for major morbidity and mortality. Moreover, patients suffering an episode of AKI consume considerable health resources. Recently, a number of studies have evaluated the implementation of automated electronic alerts (e-alerts) configured from electronic medical records (EMR) and clinical information systems (CIS) to warn healthcare providers of early or impending AKI in hospitalised patients. The impact of e-alerts on care processes, patient outcomes and health resource use, however, remains uncertain. We will perform a systematic review to describe and appraise e-alerts for AKI, and evaluate their impact on processes of care, clinical outcomes and health services use. In consultation with a research librarian, a search strategy will be developed and electronic databases (ie, MEDLINE, EMBASE, CINAHL, Cochrane Library and Inspec via Engineering Village) searched. Selected grey literature sources will also be searched. Search themes will focus on e-alerts and AKI. Citation screening, selection, quality assessment and data abstraction will be performed in duplicate. The primary analysis will be narrative; however, where feasible, pooled analysis will be performed. Each e-alert will be described according to trigger, type of alert, target recipient and degree of intrusiveness. Pooled effect estimates will be described, where applicable. Our systematic review will synthesise the literature on the value of e-alerts to detect AKI, and their impact on processes, patient-centred outcomes and resource use, and also identify key knowledge gaps and barriers to implementation. This is a fundamental step in a broader research programme aimed to understand the ideal structure of e-alerts, target population and methods for implementation, to derive benefit. Research ethics approval is not required for this review. CRD42016033033. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  5. Analysis of Alerting System Failures in Commercial Aviation Accidents

    NASA Technical Reports Server (NTRS)

    Mumaw, Randall J.

    2017-01-01

    The role of an alerting system is to make the system operator (e.g., pilot) aware of an impending hazard or unsafe state so the hazard can be avoided or managed successfully. A review of 46 commercial aviation accidents (between 1998 and 2014) revealed that, in the vast majority of events, either the hazard was not alerted or relevant hazard alerting occurred but failed to aid the flight crew sufficiently. For this set of events, alerting system failures were placed in one of five phases: Detection, Understanding, Action Selection, Prioritization, and Execution. This study also reviewed the evolution of alerting system schemes in commercial aviation, which revealed naive assumptions about pilot reliability in monitoring flight path parameters; specifically, pilot monitoring was assumed to be more effective than it actually is. Examples are provided of the types of alerting system failures that have occurred, and recommendations are provided for alerting system improvements.

  6. Feature Selection Using Information Gain for Improved Structural-Based Alert Correlation

    PubMed Central

    Siraj, Maheyzah Md; Zainal, Anazida; Elshoush, Huwaida Tagelsir; Elhaj, Fatin

    2016-01-01

    Grouping and clustering alerts for intrusion detection based on the similarity of features is referred to as structurally base alert correlation and can discover a list of attack steps. Previous researchers selected different features and data sources manually based on their knowledge and experience, which lead to the less accurate identification of attack steps and inconsistent performance of clustering accuracy. Furthermore, the existing alert correlation systems deal with a huge amount of data that contains null values, incomplete information, and irrelevant features causing the analysis of the alerts to be tedious, time-consuming and error-prone. Therefore, this paper focuses on selecting accurate and significant features of alerts that are appropriate to represent the attack steps, thus, enhancing the structural-based alert correlation model. A two-tier feature selection method is proposed to obtain the significant features. The first tier aims at ranking the subset of features based on high information gain entropy in decreasing order. The‏ second tier extends additional features with a better discriminative ability than the initially ranked features. Performance analysis results show the significance of the selected features in terms of the clustering accuracy using 2000 DARPA intrusion detection scenario-specific dataset. PMID:27893821

  7. Evaluation of health alerts from an early illness warning system in independent living.

    PubMed

    Rantz, Marilyn J; Scott, Susan D; Miller, Steven J; Skubic, Marjorie; Phillips, Lorraine; Alexander, Greg; Koopman, Richelle J; Musterman, Katy; Back, Jessica

    2013-06-01

    Passive sensor networks were deployed in independent living apartments to monitor older adults in their home environments to detect signs of impending illness and alert clinicians so they can intervene and prevent or delay significant changes in health or functional status. A retrospective qualitative deductive content analysis was undertaken to refine health alerts to improve clinical relevance to clinicians as they use alerts in their normal workflow of routine care delivery to older adults. Clinicians completed written free-text boxes to describe actions taken (or not) as a result of each alert; they also rated the clinical significance (relevance) of each health alert on a scale of 1 to 5. Two samples of the clinician's written responses to the health alerts were analyzed after alert algorithms had been adjusted based on results of a pilot study using health alerts to enhance clinical decision-making. In the first sample, a total of 663 comments were generated by seven clinicians in response to 385 unique alerts; there are more comments than alerts because more than one clinician rated the same alert. The second sample had a total of 142 comments produced by three clinicians in response to 88 distinct alerts. The overall clinical relevance of the alerts, as judged by the content of the qualitative comments by clinicians for each alert, improved from 33.3% of the alerts in the first sample classified as clinically relevant to 43.2% in the second. The goal is to produce clinically relevant alerts that clinicians find useful in daily practice. The evaluation methods used are described to assist others as they consider building and iteratively refining health alerts to enhance clinical decision making.

  8. Evaluating Alerting and Guidance Performance of a UAS Detect-And-Avoid System

    NASA Technical Reports Server (NTRS)

    Lee, Seung Man; Park, Chunki; Thipphavong, David P.; Isaacson, Douglas R.; Santiago, Confesor

    2016-01-01

    A key challenge to the routine, safe operation of unmanned aircraft systems (UAS) is the development of detect-and-avoid (DAA) systems to aid the UAS pilot in remaining "well clear" of nearby aircraft. The goal of this study is to investigate the effect of alerting criteria and pilot response delay on the safety and performance of UAS DAA systems in the context of routine civil UAS operations in the National Airspace System (NAS). A NAS-wide fast-time simulation study was conducted to assess UAS DAA system performance with a large number of encounters and a broad set of DAA alerting and guidance system parameters. Three attributes of the DAA system were controlled as independent variables in the study to conduct trade-off analyses: UAS trajectory prediction method (dead-reckoning vs. intent-based), alerting time threshold (related to predicted time to LoWC), and alerting distance threshold (related to predicted Horizontal Miss Distance, or HMD). A set of metrics, such as the percentage of true positive, false positive, and missed alerts, based on signal detection theory and analysis methods utilizing the Receiver Operating Characteristic (ROC) curves were proposed to evaluate the safety and performance of DAA alerting and guidance systems and aid development of DAA system performance standards. The effect of pilot response delay on the performance of DAA systems was evaluated using a DAA alerting and guidance model and a pilot model developed to support this study. A total of 18 fast-time simulations were conducted with nine different DAA alerting threshold settings and two different trajectory prediction methods, using recorded radar traffic from current Visual Flight Rules (VFR) operations, and supplemented with DAA-equipped UAS traffic based on mission profiles modeling future UAS operations. Results indicate DAA alerting distance threshold has a greater effect on DAA system performance than DAA alerting time threshold or ownship trajectory prediction method. Further analysis on the alert lead time (time in advance of predicted loss of well clear at which a DAA alert is first issued) indicated a strong positive correlation between alert lead time and DAA system performance (i.e. the ability of the UAS pilot to maneuver the unmanned aircraft to remain well clear). While bigger distance thresholds had beneficial effects on alert lead time and missed alert rate, it also generated a higher rate of false alerts. In the design and development of DAA alerting and guidance systems, therefore, the positive and negative effects of false alerts and missed alerts should be carefully considered to achieve acceptable alerting system performance by balancing false and missed alerts. The results and methodology presented in this study are expected to help stakeholders, policymakers and standards committees define the appropriate setting of DAA system parameter thresholds for UAS that ensure safety while minimizing operational impacts to the NAS and equipage requirements for its users before DAA operational performance standards can be finalized.

  9. Physicians’ response to computerised alerts for psychotropic drugs in older persons: a multilevel analysis of the associated alert, patient and physician characteristics

    PubMed Central

    Tamblyn, Robyn; Reidel, Kristen; Patel, Vaishali

    2012-01-01

    Objective Computerised drug alerts are expected to reduce patients’ risk of adverse drug events. However, physicians over-ride most drug alerts, because they believe that the benefit exceeds the risk. The purpose of this study was to determine the drug alert, patient and physician characteristics associated with the: (1) occurrence of psychotropic drug alerts for elderly patients and the (2) response to these alerts by their primary care physicians. Setting Primary care, Quebec, Canada. Design Prospective cohort study. Participants Sixty-one physicians using an electronic prescribing and drug alert decision-support system in their practice, and 3413 elderly patients using psychotropic drugs. Primary and secondary measures Psychotropic drug class, alert severity, patient risk for fall injuries and physician experience, practice volume and computer use were evaluated in relationship to the likelihood of having: (1) a psychotropic drug alert, (2) the prescription revised in response to an alert. Cluster-adjusted alternating logistic regression was used to assess multilevel predictors of alert occurrence and response. Results In total 13 080 psychotropic drug alerts were generated in 8931 visits. Alerts were more likely to be generated for male patients at higher risk of fall-related injury and for physicians who established the highest alert threshold. In 9.9% of alerts seen, the prescription was revised. The highest revision rate was for antipsychotic alerts (22.6%). Physicians were more likely to revise prescriptions for severe alerts (OR 2.03; 95%CI 1.39 to 2.98), if patients had cognitive impairment (OR 1.95; 95%CI 1.13 to 3.36), and if they made more visits to their physician (OR 1.05 per 5 visits; 95%CI 1 to 1.09). Conclusions Physicians view and respond to a small proportion of alerts, mainly for higher-risk patients. To reduce the risk of psychotropic drug-related fall injuries, a new generation of evidence-based drug alerts should be developed. PMID:23024254

  10. Characteristics and classification of PM2.5 pollution episodes in Beijing from 2013 to 2015.

    PubMed

    Wang, Xiaoqi; Wei, Wei; Cheng, Shuiyuan; Li, Jianbing; Zhang, Hanyu; Lv, Zhe

    2018-01-15

    During the period of 2013-2015, a total of 34 PM 2.5 pollution episodes occurred in Beijing, each of which remained for at least 2days. Among that, 28 times occurred in winter half year with the average concentration of 243.1μg/m 3 and summer half year with the average concentration of 194.1μg/m 3 . These episodes were mainly associated with lower wind speed and lower visibility as well as higher relative humidity, indicating that they belonged to heavy pollution under static stability. The PM 2.5 pollution was classified into two categories according to the back trajectory analysis and meteorological background field. Category I, accounting for 22 times among all the pollution episodes, was due to air mass transport from Beijing's southern regions with north-south direction pressure gradient and sparse isopiestic. And category II was mainly led by northwestern air masses accompanied with a large area of uniform pressure field. Then, a typical case study was conducted for each category to recognize the sub-region contribution to Beijing's PM 2.5 pollution based on WRF-CAMx modeling system, and the simulation results indicated that local emission source contribution decreased significantly during the accumulation phase for category I, but increased during that of category II, with an average contribution of 47.3% and 77.1% during the entire pollution period of each category, respectively. Two red alerts of air pollution occurred in December 2015 were also analyzed based on the episode classification. It was found that the second red alert pollution episode belonged to category II. The emission control measures in Beijing worked more obviously with the reduction effect ratio of 15.4% compared to the first red alert period (9.7%). Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Delta 13C in CO2 at Alert, NWT, Canada (June 1991 - December 2001)

    DOE Data Explorer

    Allison, C. E. [Commonwealth Scientific and Industrial Research Organization (CSIRO), Aspendale, Victoria, Australia; Francey, R. J. [Commonwealth Scientific and Industrial Research Organization (CSIRO), Aspendale, Victoria, Australia; Krummel, P. B. [Commonwealth Scientific and Industrial Research Organization (CSIRO), Aspendale, Victoria, Australia

    2003-04-01

    Measurements have been made on air collected in flasks at Alert, Canada, through the CSIRO GASLAB worldwide network. Flasks are filled with air at Alert and returned to the CSIRO GASLAB for analysis; typical sample storage times for flasks collected at Alert range from a few weeks to a few months. No significant effect on the stable carbon isotopic composition, δ13C, has been detected as a consequence of the sample storage time.

  12. Usability flaws of medication-related alerting functions: A systematic qualitative review.

    PubMed

    Marcilly, Romaric; Ammenwerth, Elske; Vasseur, Francis; Roehrer, Erin; Beuscart-Zéphir, Marie-Catherine

    2015-06-01

    Medication-related alerting functions may include usability flaws that limit their optimal use. A first step on the way to preventing usability flaws is to understand the characteristics of these usability flaws. This systematic qualitative review aims to analyze the type of usability flaws found in medication-related alerting functions. Papers were searched via PubMed, Scopus and Ergonomics Abstracts databases, along with references lists. Paper selection, data extraction and data analysis was performed by two to three Human Factors experts. Meaningful semantic units representing instances of usability flaws were the main data extracted. They were analyzed through qualitative methods: categorization following general usability heuristics and through an inductive process for the flaws specific to medication-related alerting functions. From the 6380 papers initially identified, 26 met all eligibility criteria. The analysis of the papers identified a total of 168 instances of usability flaws that could be classified into 13 categories of usability flaws representing either violations of general usability principles (i.e. they could be found in any system, e.g. guidance and workload issues) or infractions specific to medication-related alerting functions. The latter refer to issues of low signal-to-noise ratio, incomplete content of alerts, transparency, presentation mode and timing, missing alert features, tasks and control distribution. The list of 168 instances of usability flaws of medication-related alerting functions provides a source of knowledge for checking the usability of medication-related alerting functions during their design and evaluation process and ultimately constructs evidence-based usability design principles for these functions. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Personalized Alert Notifications and Evacuation Routes in Indoor Environments

    PubMed Central

    Aedo, Ignacio; Yu, Shuxin; Díaz, Paloma; Acuña, Pablo; Onorati, Teresa

    2012-01-01

    The preparedness phase is crucial in the emergency management process for reaching an adequate level of readiness to react to potential threats and hazards. During this phase, emergency plans are developed to establish, among other procedures, evacuation and emergency escape routes. Information and Communication Technologies (ICT) can support and improve these procedures providing appropriate, updated and accessible information to all people in the affected zone. Current emergency management and evacuation systems do not adapt information to the context and the profile of each person, so messages received in the emergency might be useless. In this paper, we propose a set of criteria that ICT-based systems could achieve in order to avoid this problem adapting emergency alerts and evacuation routes to different situations and people. Moreover, in order to prove the applicability of such criteria, we define a mechanism that can be used as a complement of traditional evacuation systems to provide personalized alerts and evacuation routes to all kinds of people during emergency situations in working places. This mechanism is composed by three main components: CAP-ONES for notifying emergency alerts, NERES for defining emergency plans and generating personalized evacuation routes, and iNeres as the interface to receive and visualize these routes on smartphones. The usability and understandability of proposed interface has been assessed through a user study performed in a fire simulation in an indoor environment. This evaluation demonstrated that users considered iNeres easy to understand, to learn and to use, and they also found very innovative the idea to use smartphones as a support for escaping instead of static signals on walls and doors. PMID:22969373

  14. Electronic Immunization Alerts and Spillover Effects on Other Preventive Care.

    PubMed

    Kim, Julia M; Rivera, Maria; Persing, Nichole; Bundy, David G; Psoter, Kevin J; Ghazarian, Sharon R; Miller, Marlene R; Solomon, Barry S

    2017-08-01

    The impact of electronic health record (EHR) immunization clinical alert systems on the delivery of other preventive services remains unknown. We assessed for spillover effects of an EHR immunization alert on delivery of 6 other preventive services, in children 18 to 30 months of age needing immunizations. We conducted a secondary data analysis, with additional primary data collection, of a randomized, historically controlled trial to improve immunization rates with EHR alerts, in an urban, primary care clinic. No significant differences were found in screening for anemia, lead, development, nutrition, and injury prevention counseling in children prompting EHR immunization alerts (n = 129), compared with controls (n = 135). Significant increases in oral health screening in patients prompting EHR alerts (odds ratio = 4.8, 95% CI = 1.8-13.0) were likely due to practice changes over time. An EHR clinical alert system targeting immunizations did not have a spillover effect on the delivery of other preventive services.

  15. Experimental verification, and domain definition, of structural alerts for protein binding: epoxides, lactones, nitroso, nitros, aldehydes and ketones.

    PubMed

    Nelms, M D; Cronin, M T D; Schultz, T W; Enoch, S J

    2013-01-01

    This study outlines how a combination of in chemico and Tetrahymena pyriformis data can be used to define the applicability domain of selected structural alerts within the profilers of the OECD QSAR Toolbox. Thirty-three chemicals were profiled using the OECD and OASIS profilers, enabling the applicability domain of six structural alerts to be defined, the alerts being: epoxides, lactones, nitrosos, nitros, aldehydes and ketones. Analysis of the experimental data showed the applicability domains for the epoxide, nitroso, aldehyde and ketone structural alerts to be well defined. In contrast, the data showed the applicability domains for the lactone and nitro structural alerts needed modifying. The accurate definition of the applicability domain for structural alerts within in silico profilers is important due to their use in the chemical category in predictive and regulatory toxicology. This study highlights the importance of utilizing multiple profilers in category formation.

  16. Comparison of Overridden Medication-related Clinical Decision Support in the Intensive Care Unit between a Commercial System and a Legacy System.

    PubMed

    Wong, Adrian; Wright, Adam; Seger, Diane L; Amato, Mary G; Fiskio, Julie M; Bates, David

    2017-08-23

    Electronic health records (EHRs) with clinical decision support (CDS) have shown to be effective at improving patient safety. Despite this, alerts delivered as part of CDS are overridden frequently, which is of concern in the critical care population as this group may have an increased risk of harm. Our organization recently transitioned from an internally-developed EHR to a commercial system. Data comparing various EHR systems, especially after transitions between EHRs, are needed to identify areas for improvement. To compare the two systems and identify areas for potential improvement with the new commercial system at a single institution. Overridden medication-related CDS alerts were included from October to December of the systems' respective years (legacy, 2011; commercial, 2015), restricted to three intensive care units. The two systems were compared with regards to CDS presentation and override rates for four types of CDS: drug-allergy, drug-drug interaction (DDI), geriatric and renal alerts. A post hoc analysis to evaluate for adverse drug events (ADEs) potentially resulting from overridden alerts was performed for 'contraindicated' DDIs via chart review. There was a significant increase in provider exposure to alerts and alert overrides in the commercial system (commercial: n=5,535; legacy: n=1,030). Rates of overrides were higher for the allergy and DDI alerts (p<0.001) in the commercial system. Geriatric and renal alerts were significantly different in incidence and presentation between the two systems. No ADEs were identified in an analysis of 43 overridden contraindicated DDI alerts. The vendor system had much higher rates of both alerts and overrides, although we did not find evidence of harm in a review of DDIs which were overridden. We propose recommendations for improving our current system which may be helpful to other similar institutions; improving both alert presentation and the underlying knowledge base appear important.

  17. NewYork-Presbyterian Hospital: translating innovation into practice.

    PubMed

    Johnson, Trudy; Currie, Gail; Keill, Patricia; Corwin, Steven J; Pardes, Herbert; Cooper, Mary Reich

    2005-10-01

    NewYork-Presbyterian (NYP) Hospital, a 2,242-bed not-for-profit academic medical center, was formed by a merger of The New York Hospital and The Presbyterian Hospital in the City of New York. It is also the flagship for the NewYork-Presbyterian Healthcare System, with 37 acute care facilities and 18 others. The hospital embeds safety in the culture through strategic initiatives and enhances service and efficiency using Six Sigma and other techniques to drive adoption of improvements. Goals are selected in alignment with the annual strategic initiatives, which are chosen on the basis of satisfaction surveys, patient and family complaints, community advisory groups, and performance measures, among other sources. A new business intelligence system enables online, dynamic analysis of performance results, replacing static paper reports. Advanced features in the clinical information systems include computerized physician order entry; interactive clinical alerts for decision support; a real-time infection control tracking system; and a clinical data warehouse supporting data mining and analysis for quality improvement, decision making, and education. To achieve clinical, service, and operational excellence, NYP focuses on all Institute of Medicine quality aims.

  18. Estimation of alertness levels with changes in decibel scale wavelength of EEG during dual-task simulation of auditory sonar target detection.

    PubMed

    Arjunan, Sridhar P; Kumar, Dinesh K; Jung, Tzyy-Ping

    2010-01-01

    Changes in alertness levels can have dire consequences for people operating and controlling motorized equipment. Past research studies have shown the relationship of Electroencephalogram (EEG) with alertness of the person. This research reports the fractal analysis of EEG and estimation of the alertness levels of the individual based on the changes in the maximum fractal length (MFL) of EEG. The results indicate that MFL of only 2 channels of EEG can be used to identify the loss of alertness of the individual with mean (inverse) correlation coefficient = 0.82. This study has also reported that using the changes in MFL of EEG, the changes in alertness level of a person was estimated with a mean correlation coefficient = 0.69.

  19. Optimization of drug-drug interaction alert rules in a pediatric hospital's electronic health record system using a visual analytics dashboard.

    PubMed

    Simpao, Allan F; Ahumada, Luis M; Desai, Bimal R; Bonafide, Christopher P; Gálvez, Jorge A; Rehman, Mohamed A; Jawad, Abbas F; Palma, Krisha L; Shelov, Eric D

    2015-03-01

    To develop and evaluate an electronic dashboard of hospital-wide electronic health record medication alerts for an alert fatigue reduction quality improvement project. We used visual analytics software to develop the dashboard. We collaborated with the hospital-wide Clinical Decision Support committee to perform three interventions successively deactivating clinically irrelevant drug-drug interaction (DDI) alert rules. We analyzed the impact of the interventions on care providers' and pharmacists' alert and override rates using an interrupted time series framework with piecewise regression. We evaluated 2 391 880 medication alerts between January 31, 2011 and January 26, 2014. For pharmacists, the median alert rate prior to the first DDI deactivation was 58.74 alerts/100 orders (IQR 54.98-60.48) and 25.11 alerts/100 orders (IQR 23.45-26.57) following the three interventions (p<0.001). For providers, baseline median alert rate prior to the first round of DDI deactivation was 19.73 alerts/100 orders (IQR 18.66-20.24) and 15.11 alerts/100 orders (IQR 14.44-15.49) following the three interventions (p<0.001). In a subgroup analysis, we observed a decrease in pharmacists' override rates for DDI alerts that were not modified in the system from a median of 93.06 overrides/100 alerts (IQR 91.96-94.33) to 85.68 overrides/100 alerts (IQR 84.29-87.15, p<0.001). The medication serious safety event rate decreased during the study period, and there were no serious safety events reported in association with the deactivated alert rules. An alert dashboard facilitated safe rapid-cycle reductions in alert burden that were temporally associated with lower pharmacist override rates in a subgroup of DDIs not directly affected by the interventions; meanwhile, the pharmacists' frequency of selecting the 'cancel' option increased. We hypothesize that reducing the alert burden enabled pharmacists to devote more attention to clinically relevant alerts. © The Author 2014. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. Regulatory alerts for dietary supplements in Canada and the United States, 2005-13.

    PubMed

    Abe, Andrew M; Hein, Darren J; Gregory, Philip J

    2015-06-01

    Dietary supplement regulatory alerts published by the Food and Drug Administration (FDA) and Health Canada were evaluated and characterized. FDA MedWatch and Health Canada websites were reviewed to identify regulatory alerts regarding dietary supplements from January 1, 2005, through December 31, 2013. Alerts were analyzed to identify product characteristics that may be predictive of product quality issues and potential patient harm. A total of 1560 dietary supplement-related regulatory alerts were identified. Of those, 1287 (83%) were identified through Health Canada, and 273 (18%) were identified through FDA MedWatch. The country of origin of dietary supplements associated with regulatory alerts was not provided in most regulatory alerts; however, when their origin was provided, the United States was the most common. Dietary supplements intended for sexual enhancement were the subject of 33% of all regulatory alerts identified. Products purchased online were the most likely to be associated with a regulatory alert. Dietary supplements intended for sexual enhancement, weight loss, and bodybuilding or athletic performance appeared to pose the greatest risk for patient harm due to product contamination with a pharmaceutical such as a phosphodiesterase-5 inhibitor or sibutramine. Analysis of Canadian and U.S. regulatory alerts concerning dietary supplements revealed that more than 80% of the composite alerts were issued by Health Canada. The most common intended uses of supplements for which alerts were issued were sexual enhancement, weight loss, and bodybuilding or athletic performance. The most common reason for alerts was the presence of a pharmaceutical contaminant. Copyright © 2015 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  1. Development of an "Alert Framework" Based on the Practices in the Medical Front.

    PubMed

    Sakata, Takuya; Araki, Kenji; Yamazaki, Tomoyoshi; Kawano, Koichi; Maeda, Minoru; Kushima, Muneo; Araki, Sanae

    2018-05-09

    At the University of Miyazaki Hospital (UMH), we have accumulated and semantically structured a vast amount of medical information since the activation of the electronic health record system approximately 10 years ago. With this medical information, we have decided to develop an alert system for aiding in medical treatment. The purpose of this investigation is to not only to integrate an alert framework into the electronic heath record system, but also to formulate a modeling method of this knowledge. A trial alert framework was developed for the staff in various occupational categories at the UMH. Based on findings of subsequent interviews, a more detailed and upgraded alert framework was constructed, resulting in the final model. Based on our current findings, an alert framework was developed with four major items. Based on the analysis of the medical practices from the trial model, it has been concluded that there are four major risk patterns that trigger the alert. Furthermore, the current alert framework contains detailed definitions which are easily substituted into the database, leading to easy implementation of the electronic health records.

  2. The effect of mental alerting on peripheral vestibular nystagmus during spontaneous, gaze (30 degrees left, 30 degrees right) and body positional (left & right lateral lying) testing using electronystagmography (ENG).

    PubMed

    McGovern, Tracey N; Fitzgerald, John E

    2008-10-01

    The performance of mental alerting during caloric testing has always been considered important, however its use/benefit during electronystagmography (ENG)/videonystagmography (VNG) testing has been questioned. The aim of this study was to investigate the effect of mental alerting tasks on peripheral type vestibular nystagmus recorded during ENG. Thirty patients with significant spontaneous/gaze or positional nystagmus (slow phase velocity >or= 6 degrees /s) were recruited from consecutive referrals for vestibular assessment. Nystagmus was recorded by ENG both in the presence and absence of mental alerting for each patient. Investigation of nystagmus by analysis of variance (ANOVA) revealed significantly larger nystagmus (higher value SPV) with mental alerting than with no alerting (p<0.001), and for some patients nystagmus traces were reduced to a flat line (no nystagmus) with no alerting. The study demonstrates the importance of mental alerting in helping overcome central suppression of nystagmus and highlights its importance to help identify peripheral type nystagmus during ENG.

  3. Development and preliminary evidence for the validity of an instrument assessing implementation of human-factors principles in medication-related decision-support systems—I-MeDeSA

    PubMed Central

    Zachariah, Marianne; Seidling, Hanna M; Neri, Pamela M; Cresswell, Kathrin M; Duke, Jon; Bloomrosen, Meryl; Volk, Lynn A; Bates, David W

    2011-01-01

    Background Medication-related decision support can reduce the frequency of preventable adverse drug events. However, the design of current medication alerts often results in alert fatigue and high over-ride rates, thus reducing any potential benefits. Methods The authors previously reviewed human-factors principles for relevance to medication-related decision support alerts. In this study, instrument items were developed for assessing the appropriate implementation of these human-factors principles in drug–drug interaction (DDI) alerts. User feedback regarding nine electronic medical records was considered during the development process. Content validity, construct validity through correlation analysis, and inter-rater reliability were assessed. Results The final version of the instrument included 26 items associated with nine human-factors principles. Content validation on three systems resulted in the addition of one principle (Corrective Actions) to the instrument and the elimination of eight items. Additionally, the wording of eight items was altered. Correlation analysis suggests a direct relationship between system age and performance of DDI alerts (p=0.0016). Inter-rater reliability indicated substantial agreement between raters (κ=0.764). Conclusion The authors developed and gathered preliminary evidence for the validity of an instrument that measures the appropriate use of human-factors principles in the design and display of DDI alerts. Designers of DDI alerts may use the instrument to improve usability and increase user acceptance of medication alerts, and organizations selecting an electronic medical record may find the instrument helpful in meeting their clinicians' usability needs. PMID:21946241

  4. An Enhanced Secure Identity-Based Certificateless Public Key Authentication Scheme for Vehicular Sensor Networks.

    PubMed

    Li, Congcong; Zhang, Xi; Wang, Haiping; Li, Dongfeng

    2018-01-11

    Vehicular sensor networks have been widely applied in intelligent traffic systems in recent years. Because of the specificity of vehicular sensor networks, they require an enhanced, secure and efficient authentication scheme. Existing authentication protocols are vulnerable to some problems, such as a high computational overhead with certificate distribution and revocation, strong reliance on tamper-proof devices, limited scalability when building many secure channels, and an inability to detect hardware tampering attacks. In this paper, an improved authentication scheme using certificateless public key cryptography is proposed to address these problems. A security analysis of our scheme shows that our protocol provides an enhanced secure anonymous authentication, which is resilient against major security threats. Furthermore, the proposed scheme reduces the incidence of node compromise and replication attacks. The scheme also provides a malicious-node detection and warning mechanism, which can quickly identify compromised static nodes and immediately alert the administrative department. With performance evaluations, the scheme can obtain better trade-offs between security and efficiency than the well-known available schemes.

  5. Changes in decibel scale wavelength properties of EEG with alertness levels while performing sustained attention tasks.

    PubMed

    Arjunan, Sridhar P; Kumar, Dinesh K; Jung, Tzyy-Ping

    2009-01-01

    Loss of alertness can have dire consequences for people controlling motorized equipment or for people in professions such as defense. Electroencephalogram (EEG) is known to be related to alertness of the person, but due to high level of noise and low signal strength, the use of EEG for such applications has been considered to be unreliable. This study reports the fractal analysis of EEG and identifies the use of maximum fractal length (MFL) as a feature that is inversely correlated with the alertness of the subject. The results show that MFL (of only single channel of EEG) indicates the loss of alertness of the individual with mean (inverse) correlation coefficient = 0.82.

  6. Impact of Homeland Security Alert level on calls to a law enforcement peer support hotline.

    PubMed

    Omer, Saad B; Barnett, Daniel J; Castellano, Cherie; Wierzba, Rachel K; Hiremath, Girish S; Balicer, Ran D; Everly, George S

    2007-01-01

    The Homeland Security Advisory System (HSAS) was established by the Department of Homeland Security to communicate the risk of a terrorist event. In order to explore the potential psychological impacts of HSAS we analyzed the effects of terror alerts on the law enforcement community. We used data from the New Jersey Cop 2 Cop crisis intervention hotline. Incidence Rate Ratios--interpreted as average relative increases in the daily number of calls to the Cop 2 Cop hotline during an increased alert period--were computed from Poisson models. The hotline received a total of 4,145 initial calls during the study period. The mean daily number of calls was higher during alert level elevation compared to prior 7 days (7.68 vs. 8.00). In the Poisson regression analysis, the Incidence Rate Ratios of number of calls received during elevated alert levels compared to the reference period of seven days preceding each change in alert were close to 1, with confidence intervals crossing 1 (i.e. not statistically significant) for all lag periods evaluated. This investigation, in the context of New Jersey law enforcement personnel, does not support the concern that elevating the alert status places undue stress upon alert recipients.

  7. FT4 Data Analysis Summary (SSI-ARC)

    NASA Technical Reports Server (NTRS)

    Isaacson, Douglas R.; Gong, Chester; Reardon, Scott Edward; Santiago, Confesor

    2016-01-01

    Standards for Unmanned Aircraft System (UAS) Detect-and-Avoid (DAA) systems are currently being developed under the auspices of the RTCA Special Committee 228 (SC-228). To support the development of these standards, a series of flight tests has been conducted at NASAs Armstrong Flight Research Center (NASA-AFRC). The fourth in this series of flight test activities (Flight Test 4, or simply FT4) was conducted during the Spring and Summer of 2016. FT4 supported the objectives of numerous organizations working toward UAS DAA Minimum Operational Performance Standards (MOPS) and UAS DAA Radar MOPS. The summary provided herein is limited to the objectives, analysis and conclusions of the NASA Ames Research Center (NASA-ARC) SSI team toward the refinement of UAS DAA MOPS. This document provides a high-level overview of FT4 and the SSI-ARC objectives, a summary of the data analysis methodology and recommendations for UAS DAA MOPS refinements based on the data analysis results. A total of 72 encounters were flown to support SSI-ARC objectives. Test results were generally consistent with acceptable UAS DAA system performance and will be considered in broader SC-228 requirements validation efforts. Observed alert lead times indicated acceptable UAS DAA alerting performance. Effective interoperability between the UAS DAA system and the Traffic Alert and Collision Avoidance System (TCAS) was observed with one notable exception: TCAS Resolutions Advisories (RA) were observed in the absence of any DAA alert on two occasions, indicating the need for alert parameter refinement. Findings further indicated the need for continued work in the areas of DAA Well Clear Recovery logic and alert stability for Mode-C-only intruders. Finally, results demonstrated a high level of compliance with a set of evaluation criteria designed to provide anecdotal evidence of acceptable UAS DAA system performance.

  8. The DOPA decarboxylase (DDC) gene is associated with alerting attention.

    PubMed

    Zhu, Bi; Chen, Chuansheng; Moyzis, Robert K; Dong, Qi; Chen, Chunhui; He, Qinghua; Li, Jin; Li, Jun; Lei, Xuemei; Lin, Chongde

    2013-06-03

    DOPA decarboxylase (DDC) is involved in the synthesis of dopamine, norepinephrine and serotonin. It has been suggested that genes involved in the dopamine, norepinephrine, and cholinergic systems play an essential role in the efficiency of human attention networks. Attention refers to the cognitive process of obtaining and maintaining the alert state, orienting to sensory events, and regulating the conflicts of thoughts and behavior. The present study tested seven single nucleotide polymorphisms (SNPs) within the DDC gene for association with attention, which was assessed by the Attention Network Test to detect three networks of attention, including alerting, orienting, and executive attention, in a healthy Han Chinese sample (N=451). Association analysis for individual SNPs indicated that four of the seven SNPs (rs3887825, rs7786398, rs10499695, and rs6969081) were significantly associated with alerting attention. Haplotype-based association analysis revealed that alerting was associated with the haplotype G-A-T for SNPs rs7786398-rs10499695-rs6969081. These associations remained significant after correcting for multiple testing by max(T) permutation. No association was found for orienting and executive attention. This study provides the first evidence for the involvement of the DDC gene in alerting attention. A better understanding of the genetic basis of distinct attention networks would allow us to develop more effective diagnosis, treatment, and prevention of deficient or underdeveloped alerting attention as well as its related prevalent neuropsychiatric disorders. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. Taking up national safety alerts to improve patient safety in hospitals: The perspective of healthcare quality and risk managers.

    PubMed

    Pfeiffer, Yvonne; Schwappach, David

    2016-01-01

    National safety alert systems publish relevant information to improve patient safety in hospitals. However, the information has to be transformed into local action to have an effect on patient safety. We studied three research questions: How do Swiss healthcare quality and risk managers (qm/rm(1)) see their own role in learning from safety alerts issued by the Swiss national voluntary reporting and analysis system? What are their attitudes towards and evaluations of the alerts, and which types of improvement actions were fostered by the safety alerts? A survey was developed and applied to Swiss healthcare risk and quality managers, with a response rate of 39 % (n=116). Descriptive statistics are presented. The qm/rm disseminate and communicate with a broad variety of professional groups about the alerts. While most respondents felt that they should know the alerts and their contents, only a part of them felt responsible for driving organizational change based on the recommendations. However, most respondents used safety alerts to back up their own patient safety goals. The alerts were evaluated positively on various dimensions such as usefulness and were considered as standards of good practice by the majority of the respondents. A range of organizational responses was applied, with disseminating information being the most common. An active role is related to using safety alerts for backing up own patient safety goals. To support an active role of qm/rm in their hospital's learning from safety alerts, appropriate organizational structures should be developed. Furthermore, they could be given special information or training to act as an information hub on the issues discussed in the alerts. Copyright © 2016. Published by Elsevier GmbH.

  10. The Nature and Variability of Automated Practice Alerts Derived from Electronic Health Records in a U.S. Nationwide Critical Care Research Network.

    PubMed

    Benthin, Cody; Pannu, Sonal; Khan, Akram; Gong, Michelle

    2016-10-01

    The nature, variability, and extent of early warning clinical practice alerts derived from automated query of electronic health records (e-alerts) currently used in acute care settings for clinical care or research is unknown. To describe e-alerts in current use in acute care settings at medical centers participating in a nationwide critical care research network. We surveyed investigators at 38 institutions involved in the National Institutes of Health-funded Clinical Trials Network for the Prevention and Early Treatment of Acute Lung Injury (PETAL) for quantitative and qualitative analysis. Thirty sites completed the survey (79% response rate). All sites used electronic health record systems. Epic Systems was used at 56% of sites; the others used alternate commercially available vendors or homegrown systems. Respondents at 57% of sites represented in this survey used e-alerts. All but 1 of these 17 sites used an e-alert for early detection of sepsis-related syndromes, and 35% used an e-alert for pneumonia. E-alerts were triggered by abnormal laboratory values (37%), vital signs (37%), or radiology reports (15%) and were used about equally for clinical decision support and research. Only 59% of sites with e-alerts have evaluated them either for accuracy or for validity. A majority of the research network sites participating in this survey use e-alerts for early notification of potential threats to hospitalized patients; however, there was significant variability in the nature of e-alerts between institutions. Use of one common electronic health record vendor at more than half of the participating sites suggests that it may be possible to standardize e-alerts across multiple sites in research networks, particularly among sites using the same medical record platform.

  11. Modeling Pilot State in Next Generation Aircraft Alert Systems

    NASA Technical Reports Server (NTRS)

    Carlin, Alan S.; Alexander, Amy L.; Schurr, Nathan

    2011-01-01

    The Next Generation Air Transportation System will introduce new, advanced sensor technologies into the cockpit that must convey a large number of potentially complex alerts. Our work focuses on the challenges associated with prioritizing aircraft sensor alerts in a quick and efficient manner, essentially determining when and how to alert the pilot This "alert decision" becomes very difficult in NextGen due to the following challenges: 1) the increasing number of potential hazards, 2) the uncertainty associated with the state of potential hazards as well as pilot slate , and 3) the limited time to make safely-critical decisions. In this paper, we focus on pilot state and present a model for anticipating duration and quality of pilot behavior, for use in a larger system which issues aircraft alerts. We estimate pilot workload, which we model as being dependent on factors including mental effort, task demands. and task performance. We perform a mathematically rigorous analysis of the model and resulting alerting plans. We simulate the model in software and present simulated results with respect to manipulation of the pilot measures.

  12. Alertness Modulates Conflict Adaptation and Feature Integration in an Opposite Way

    PubMed Central

    Chen, Jia; Huang, Xiting; Chen, Antao

    2013-01-01

    Previous studies show that the congruency sequence effect can result from both the conflict adaptation effect (CAE) and feature integration effect which can be observed as the repetition priming effect (RPE) and feature overlap effect (FOE) depending on different experimental conditions. Evidence from neuroimaging studies suggests that a close correlation exists between the neural mechanisms of alertness-related modulations and the congruency sequence effect. However, little is known about whether and how alertness mediates the congruency sequence effect. In Experiment 1, the Attentional Networks Test (ANT) and a modified flanker task were used to evaluate whether the alertness of the attentional functions had a correlation with the CAE and RPE. In Experimental 2, the ANT and another modified flanker task were used to investigate whether alertness of the attentional functions correlate with the CAE and FOE. In Experiment 1, through the correlative analysis, we found a significant positive correlation between alertness and the CAE, and a negative correlation between the alertness and the RPE. Moreover, a significant negative correlation existed between CAE and RPE. In Experiment 2, we found a marginally significant negative correlation between the CAE and the RPE, but the correlation between alertness and FOE, CAE and FOE was not significant. These results suggest that alertness can modulate conflict adaptation and feature integration in an opposite way. Participants at the high alerting level group may tend to use the top-down cognitive processing strategy, whereas participants at the low alerting level group tend to use the bottom-up processing strategy. PMID:24250824

  13. Wide variation and patterns of physicians' responses to drug-drug interaction alerts.

    PubMed

    Cho, Insook; Lee, Yura; Lee, Jae-Ho; Bates, David W

    2018-05-08

    Providing physicians with alerts about potentially harmful drug-drug interactions (DDIs) is only moderately effective due to high alert override rates. To understand high override behavior on DDI alerts, we investigated how physicians respond to DDIs and their behavior patterns and variations. Retrospective system log data analysis and records review (sampling 2% of total overrides). A large tertiary academic hospital. About 560 physicians and their override responses to DDI alerts generated from 1 September to 31 December 2014. Not applicable. DDI alert frequency and override rate. We found significant variation in both the number of alerts and override rates at the levels of physicians, departments and drug-class pairs. Physician-level variations were wider for residents than for faculty staff (number of alerts: t = 254.17, P = 0.011; override rates: t = -4.77, P < 0.0001). Using the number of alerts and their override rate, we classified physicians into four groups: inexperienced incautious users, inexperienced cautious users, experienced cautious users and experienced incautious users. Medical department influenced both alert numbers and override rates. Nearly 90% of the overrides involved only five drug-class combinations, which had a wide range of appropriateness in the chart review. The variations at drug-class levels suggest issues with system design and the DDI rules. Department-level variation may be best addressed at the department level, and the rest of the variation appears related to individual physician responses, suggesting the need for interventions at an individual level.

  14. Alert management for home healthcare based on home automation analysis.

    PubMed

    Truong, T T; de Lamotte, F; Diguet, J-Ph; Said-Hocine, F

    2010-01-01

    Rising healthcare for elder and disabled people can be controlled by offering people autonomy at home by means of information technology. In this paper, we present an original and sensorless alert management solution which performs multimedia and home automation service discrimination and extracts highly regular home activities as sensors for alert management. The results of simulation data, based on real context, allow us to evaluate our approach before application to real data.

  15. [Materials and articles intended to come into contact with food: evaluation of the rapid alert system for food and feed (RASFF) 2008-2010].

    PubMed

    Baiguini, Alessandro; Colletta, Stefano; Rebella, Valentina

    2011-01-01

    For some time, packaging materials and articles intended to come into contact with food are included in the system of controls, early warnings and risk communication provided by the European Commission (EU) regulation 178/2002. Data analysis of the EU rapid alert system for food allows one to define a specific risk profile and to establish an effective plan for official control of materials intended to come into contact with food. In the 2008-2010 period the rapid alert system has ratified alert notifications, mostly related to plastic materials of Chinese origin.

  16. Alert Workplace From Healthcare Workers' Perspective: Behavioral and Environmental Strategies to Improve Vigilance and Alertness in Healthcare Settings.

    PubMed

    Sagah Zadeh, Rana; Shepley, Mardelle; Sadatsafavi, Hessam; Owora, Arthur Hamie; Krieger, Ana C

    2018-04-01

    This study aims to identify the behavioral and environmental strategies that healthcare workers view as helpful for managing sleepiness, improving alertness, and therefore optimizing workplace safety. Reduced alertness is a common issue in healthcare work environments and is associated with impaired cognitive performance and decision-making ability as well as increased errors and injuries. We surveyed 136 healthcare professionals at a primary care clinic, an acute care hospital, and a mental health clinic. Nonstructured, semistructured, and structured questionnaires were used to elicit relevant information which was analyzed using qualitative content analysis and logistic regression models, respectively. In order by frequency of endorsement: dietary intervention; physical mobility; cognitive, sensory, or social stimulation; personal lifestyle strategies; and rest/nap opportunities were reported as behavioral strategies used to address workplace alertness. Compared to other environmental features, daylight and thermal comfort were perceived to be more important to addressing workplace alertness ( p < .05). By optimizing the physical environment and organizational policies and providing education programs, we have an opportunity to support healthcare professionals in managing sleepiness and maintaining alertness at work. In addition, such system level interventions may reduce unhealthy choices such as frequent caffeine intake to keep alert. The development of multidisciplinary evidence-based guidelines is needed to address sleepiness and alertness to improve workplace safety in healthcare facilities.

  17. The Montsec Observatory and the Gaia science alerts

    NASA Astrophysics Data System (ADS)

    Carrasco, J. M.; Burgaz, U.; Vilardell, F.; Jordi, C.

    2017-03-01

    The continuous and reiterative scan of the whole sky performed by Gaia ESA's mission during its (at least) 5 years of mission allows to detect transient events (e.g., supernovae, microlensing events, cataclysmic variables, etc) almost in real time among the daily millions of observations. The pipeline in charge to discover these alerts does a quick look analysis of the daily data stream, identify those sources increasing their brightness with respect to previous Gaia observations and also analyse their spectrophotometry to decide if those sources are good candidates to be published as a Gaia Photometric Science Alerts. These events are publicly announced for follow-up observations (both photometric and spectroscopic are needed). Observatories around the world confirm, classify and study them in detail. Observations are put in common and analysed together in a common interface in order to get a single analysis as detailed and precise as possible. Our team in Barcelona contributes to this Gaia science alerts follow-up programme with the 0.8 m robotic telescope Joan Oró (TJO), at the Montsec Observatory (OAdM), located at Sant Esteve de la Sarga (Lleida, Spain) performing photometric observations to derive the lightcurves of the most interesting alerts accessible from the observatory. Until now we have contributed with about 4500 images in multicolour Johnson-Cousins passbands obtained with TJO for a total of 38 Gaia science alerts, becoming the third most contributing observatory in the programme. Here we summarise the procedure to select new targets to be observed by TJO, submit follow-up observations and we explain the analysis we did for some interesting obtained lightcurves.

  18. Modeling, Analyzing, and Mitigating Dissonance Between Alerting Systems

    NASA Technical Reports Server (NTRS)

    Song, Lixia; Kuchar, James K.

    2003-01-01

    Alerting systems are becoming pervasive in process operations, which may result in the potential for dissonance or conflict in information from different alerting systems that suggests different threat levels and/or actions to resolve hazards. Little is currently available to help in predicting or solving the dissonance problem. This thesis presents a methodology to model and analyze dissonance between alerting systems, providing both a theoretical foundation for understanding dissonance and a practical basis from which specific problems can be addressed. A state-space representation of multiple alerting system operation is generalized that can be tailored across a variety of applications. Based on the representation, two major causes of dissonance are identified: logic differences and sensor error. Additionally, several possible types of dissonance are identified. A mathematical analysis method is developed to identify the conditions for dissonance originating from logic differences. A probabilistic analysis methodology is developed to estimate the probability of dissonance originating from sensor error, and to compare the relative contribution to dissonance of sensor error against the contribution from logic differences. A hybrid model, which describes the dynamic behavior of the process with multiple alerting systems, is developed to identify dangerous dissonance space, from which the process can lead to disaster. Methodologies to avoid or mitigate dissonance are outlined. Two examples are used to demonstrate the application of the methodology. First, a conceptual In-Trail Spacing example is presented. The methodology is applied to identify the conditions for possible dissonance, to identify relative contribution of logic difference and sensor error, and to identify dangerous dissonance space. Several proposed mitigation methods are demonstrated in this example. In the second example, the methodology is applied to address the dissonance problem between two air traffic alert and avoidance systems: the existing Traffic Alert and Collision Avoidance System (TCAS) vs. the proposed Airborne Conflict Management system (ACM). Conditions on ACM resolution maneuvers are identified to avoid dynamic dissonance between TCAS and ACM. Also included in this report is an Appendix written by Lee Winder about recent and continuing work on alerting systems design. The application of Markov Decision Process (MDP) theory to complex alerting problems is discussed and illustrated with an abstract example system.

  19. Identification of Patients Expected to Benefit from Electronic Alerts for Acute Kidney Injury.

    PubMed

    Biswas, Aditya; Parikh, Chirag R; Feldman, Harold I; Garg, Amit X; Latham, Stephen; Lin, Haiqun; Palevsky, Paul M; Ugwuowo, Ugochukwu; Wilson, F Perry

    2018-06-07

    Electronic alerts for heterogenous conditions such as AKI may not provide benefit for all eligible patients and can lead to alert fatigue, suggesting that personalized alert targeting may be useful. Uplift-based alert targeting may be superior to purely prognostic-targeting of interventions because uplift models assess marginal treatment effect rather than likelihood of outcome. This is a secondary analysis of a clinical trial of 2278 adult patients with AKI randomized to an automated, electronic alert system versus usual care. We used three uplift algorithms and one purely prognostic algorithm, trained in 70% of the data, and evaluated the effect of targeting alerts to patients with higher scores in the held-out 30% of the data. The performance of the targeting strategy was assessed as the interaction between the model prediction of likelihood to benefit from alerts and randomization status. The outcome of interest was maximum relative change in creatinine from the time of randomization to 3 days after randomization. The three uplift score algorithms all gave rise to a significant interaction term, suggesting that a strategy of targeting individuals with higher uplift scores would lead to a beneficial effect of AKI alerting, in contrast to the null effect seen in the overall study. The prognostic model did not successfully stratify patients with regards to benefit of the intervention. Among individuals in the high uplift group, alerting was associated with a median reduction in change in creatinine of -5.3% ( P =0.03). In the low uplift group, alerting was associated with a median increase in change in creatinine of +5.3% ( P =0.005). Older individuals, women, and those with a lower randomization creatinine were more likely to receive high uplift scores, suggesting that alerts may benefit those with more slowly developing AKI. Uplift modeling, which accounts for treatment effect, can successfully target electronic alerts for AKI to those most likely to benefit, whereas purely prognostic targeting cannot. Copyright © 2018 by the American Society of Nephrology.

  20. Alerts Analysis and Visualization in Network-based Intrusion Detection Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Dr. Li

    2010-08-01

    The alerts produced by network-based intrusion detection systems, e.g. Snort, can be difficult for network administrators to efficiently review and respond to due to the enormous number of alerts generated in a short time frame. This work describes how the visualization of raw IDS alert data assists network administrators in understanding the current state of a network and quickens the process of reviewing and responding to intrusion attempts. The project presented in this work consists of three primary components. The first component provides a visual mapping of the network topology that allows the end-user to easily browse clustered alerts. Themore » second component is based on the flocking behavior of birds such that birds tend to follow other birds with similar behaviors. This component allows the end-user to see the clustering process and provides an efficient means for reviewing alert data. The third component discovers and visualizes patterns of multistage attacks by profiling the attacker s behaviors.« less

  1. Prototype Conflict Alerting Logic for Free Flight

    NASA Technical Reports Server (NTRS)

    Yang, Lee C.; Kuchar, James K.

    1997-01-01

    This paper discusses the development of a prototype alerting system for a conceptual Free Flight environment. The concept assumes that datalink between aircraft is available and that conflicts are primarily resolved on the flight deck. Four alert stages are generated depending on the likelihood of a conflict. If the conflict is not resolved by the flight crews, Air Traffic Control is notified to take over separation authority. The alerting logic is based on probabilistic analysis through modeling of aircraft sensor and trajectory uncertainties. Monte Carlo simulations were used over a range of encounter situations to determine conflict probability. The four alert stages were then defined based on probability of conflict and on the number of avoidance maneuvers available to the flight crew. Preliminary results from numerical evaluations and from a piloted simulator study at NASA Ames Research Center are summarized.

  2. Personalized and automated remote monitoring of atrial fibrillation.

    PubMed

    Rosier, Arnaud; Mabo, Philippe; Temal, Lynda; Van Hille, Pascal; Dameron, Olivier; Deléger, Louise; Grouin, Cyril; Zweigenbaum, Pierre; Jacques, Julie; Chazard, Emmanuel; Laporte, Laure; Henry, Christine; Burgun, Anita

    2016-03-01

    Remote monitoring of cardiac implantable electronic devices is a growing standard; yet, remote follow-up and management of alerts represents a time-consuming task for physicians or trained staff. This study evaluates an automatic mechanism based on artificial intelligence tools to filter atrial fibrillation (AF) alerts based on their medical significance. We evaluated this method on alerts for AF episodes that occurred in 60 pacemaker recipients. AKENATON prototype workflow includes two steps: natural language-processing algorithms abstract the patient health record to a digital version, then a knowledge-based algorithm based on an applied formal ontology allows to calculate the CHA2DS2-VASc score and evaluate the anticoagulation status of the patient. Each alert is then automatically classified by importance from low to critical, by mimicking medical reasoning. Final classification was compared with human expert analysis by two physicians. A total of 1783 alerts about AF episode >5 min in 60 patients were processed. A 1749 of 1783 alerts (98%) were adequately classified and there were no underestimation of alert importance in the remaining 34 misclassified alerts. This work demonstrates the ability of a pilot system to classify alerts and improves personalized remote monitoring of patients. In particular, our method allows integration of patient medical history with device alert notifications, which is useful both from medical and resource-management perspectives. The system was able to automatically classify the importance of 1783 AF alerts in 60 patients, which resulted in an 84% reduction in notification workload, while preserving patient safety. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  3. What to Expect from the Virtual Seismologist: Delay Times and Uncertainties of Initial Earthquake Alerts in California

    NASA Astrophysics Data System (ADS)

    Behr, Y.; Cua, G. B.; Clinton, J. F.; Racine, R.; Meier, M.; Cauzzi, C.

    2013-12-01

    The Virtual Seismologist (VS) method is a Bayesian approach to regional network-based earthquake early warning (EEW) originally formulated by Cua and Heaton (2007). Implementation of VS into real-time EEW codes has been an on-going effort of the Swiss Seismological Service at ETH Zürich since 2006, with support from ETH Zürich, various European projects, and the United States Geological Survey (USGS). VS is one of three EEW algorithms that form the basis of the California Integrated Seismic Network (CISN) ShakeAlert system, a USGS-funded prototype end-to-end EEW system that could potentially be implemented in California. In Europe, VS is currently operating as a real-time test system in Switzerland, western Greece and Istanbul. As part of the on-going EU project REAKT (Strategies and Tools for Real-Time Earthquake Risk Reduction), VS installations in southern Italy, Romania, and Iceland are planned or underway. The possible use cases for an EEW system will be determined by the speed and reliability of earthquake source parameter estimates. A thorough understanding of both is therefore essential to evaluate the usefulness of VS. For California, we present state-wide theoretical alert times for hypothetical earthquakes by analyzing time delays introduced by the different components in the VS EEW system. Taking advantage of the fully probabilistic formulation of the VS algorithm we further present an improved way to describe the uncertainties of every magnitude estimate by evaluating the width and shape of the probability density function that describes the relationship between waveform envelope amplitudes and magnitude. We evaluate these new uncertainty values for past seismicity in California through off-line playbacks and compare them to the previously defined static definitions of uncertainty based on real-time detections. Our results indicate where VS alerts are most useful in California and also suggest where most effective improvements to the VS EEW system can be made.

  4. Evaluation of prescriber responses to pharmacogenomics clinical decision support for thiopurine S-methyltransferase testing.

    PubMed

    Ubanyionwu, Samuel; Formea, Christine M; Anderson, Benjamin; Wix, Kelly; Dierkhising, Ross; Caraballo, Pedro J

    2018-02-15

    Results of a study of prescribers' responses to a pharmacogenomics-based clinical decision support (CDS) alert designed to prompt thiopurine S -methyltransferase (TPMT) status testing are reported. A single-center, retrospective, chart review-based study was conducted to evaluate prescriber compliance with a pretest CDS alert that warned of potential thiopurine drug toxicity resulting from deficient TPMT activity due to TPMT gene polymorphism. The CDS alert was triggered when prescribers ordered thiopurine drugs for patients whose records did not indicate TPMT status or when historical thiopurine use was documented in the electronic health record. The alert pop-up also provided a link to online educational resources to guide thiopurine dosing calculations. During the 9-month study period, 500 CDS alerts were generated: in 101 cases (20%), TPMT phenotyping or TPMT genotyping was ordered; in 399 cases (80%), testing was not ordered. Multivariable regression analysis indicated that documentation of historical thiopurine use was the only independent predictor of test ordering. Among the 99 patients tested subsequent to CDS alerts, 70 (71%) had normal TPMT activity, 29 (29%) had intermediate activity, and none had deficient activity. The online resources provided thiopurine dosing recommendations applicable to 24 patients, but only 3 were prescribed guideline-supported doses after CDS alerts. The pretest CDS rule resulted in a large proportion of neglected alerts due to poor alerting accuracy and consequent alert fatigue. Prescriber usage of online thiopurine dosing resources was low. Copyright © 2018 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  5. Interventions for implementation of thromboprophylaxis in hospitalized patients at risk for venous thromboembolism.

    PubMed

    Kahn, Susan R; Morrison, David R; Diendéré, Gisèle; Piché, Alexandre; Filion, Kristian B; Klil-Drori, Adi J; Douketis, James D; Emed, Jessica; Roussin, André; Tagalakis, Vicky; Morris, Martin; Geerts, William

    2018-04-24

    Venous thromboembolism (VTE) is a leading cause of morbidity and mortality in hospitalized patients. While numerous randomized controlled trials (RCTs) have shown that the appropriate use of thromboprophylaxis in hospitalized patients at risk for VTE is safe, effective, and cost-effective, thromboprophylaxis remains underused or inappropriately used. Our previous review suggested that system-wide interventions, such as education, alerts, and multifaceted interventions were more effective at improving the prescribing of thromboprophylaxis than relying on individual providers' behaviors. However, 47 of the 55 included studies in our previous review were observational in design. Thus, an update to our systematic review, focused on the higher level of evidence of RCTs only, was warranted. To assess the effects of system-wide interventions designed to increase the implementation of thromboprophylaxis and decrease the incidence of VTE in hospitalized adult medical and surgical patients at risk for VTE, focusing on RCTs only. Our research librarian conducted a systematic literature search of MEDLINE Ovid, and subsequently translated it to CENTRAL, PubMed, Embase Ovid, BIOSIS Previews Ovid, CINAHL, Web of Science, the Database of Abstracts of Reviews of Effects (DARE; in the Cochrane Library), NHS Economic Evaluation Database (EED; in the Cochrane Library), LILACS, and clinicaltrials.gov from inception to 7 January 2017. We also screened reference lists of relevant review articles. We identified 12,920 potentially relevant records. We included all types of RCTs, with random or quasi-random methods of allocation of interventions, which either randomized individuals (e.g. parallel group, cross-over, or factorial design RCTs), or groups of individuals (cluster RCTs (CRTs)), which aimed to increase the use of prophylaxis or appropriate prophylaxis, or decrease the occurrence of VTE in hospitalized adult patients. We excluded observational studies, studies in which the intervention was simply distribution of published guidelines, and studies whose interventions were not clearly described. Studies could be in any language. We collected data on the following outcomes: the number of participants who received prophylaxis or appropriate prophylaxis (as defined by study authors), the occurrence of any VTE (symptomatic or asymptomatic), mortality, and safety outcomes, such as bleeding. We categorized the interventions into alerts (computer or human alerts), multifaceted interventions (combination of interventions that could include an alert component), educational interventions (e.g. grand rounds, courses), and preprinted orders (written predefined orders completed by the physician on paper or electronically). We meta-analyzed data across RCTs using a random-effects model. For CRTs, we pooled effect estimates (risk difference (RD) and risk ratio (RR), with 95% confidence interval (CI), adjusted for clustering, when possible. We pooled results if three or more trials were available for a particular intervention. We assessed the certainty of the evidence according to the GRADE approach. From the 12,920 records identified by our search, we included 13 RCTs (N = 35,997 participants) in our qualitative analysis and 11 RCTs (N = 33,207 participants) in our meta-analyses. Alerts were associated with an increase in the proportion of participants who received prophylaxis (RD 21%, 95% CI 15% to 27%; three studies; 5057 participants; I² = 75%; low-certainty evidence). The substantial statistical heterogeneity may be in part explained by patient types, type of hospital, and type of alert. Subgroup analyses were not feasible due to the small number of studies included in the meta-analysis.Multifaceted interventions were associated with a small increase in the proportion of participants who received prophylaxis (cluster-adjusted RD 4%, 95% CI 2% to 6%; five studies; 9198 participants; I² = 0%; moderate-certainty evidence). Multifaceted interventions with an alert component were found to be more effective than multifaceted interventions that did not include an alert, although there were not enough studies to conduct a pooled analysis. Alerts were associated with an increase in the proportion of participants who received appropriate prophylaxis (RD 16%, 95% CI 12% to 20%; three studies; 1820 participants; I² = 0; moderate-certainty evidence). Alerts were also associated with a reduction in the rate of symptomatic VTE at three months (RR 64%, 95% CI 47% to 86%; three studies; 5353 participants; I² = 15%; low-certainty evidence). Computer alerts were associated with a reduction in the rate of symptomatic VTE, although there were not enough studies to pool computer alerts and human alerts results separately. We reviewed RCTs that implemented a variety of system-wide strategies aimed at improving thromboprophylaxis in hospitalized patients. We found increased prescription of prophylaxis associated with alerts and multifaceted interventions, and increased prescription of appropriate prophylaxis associated with alerts. While multifaceted interventions were found to be less effective than alerts, a multifaceted intervention with an alert was more effective than one without an alert. Alerts, particularly computer alerts, were associated with a reduction in symptomatic VTE at three months, although there were not enough studies to pool computer alerts and human alerts results separately.Our analysis was underpowered to assess the effect on mortality and safety outcomes, such as bleeding.The incomplete reporting of relevant study design features did not allow complete assessment of the certainty of the evidence. However, the certainty of the evidence for improvement in outcomes was judged to be better than for our previous review (low- to moderate-certainty evidence, compared to very low-certainty evidence for most outcomes). The results of our updated review will help physicians, hospital administrators, and policy makers make practical decisions about adopting specific system-wide measures to improve prescription of thromboprophylaxis, and ultimately prevent VTE in hospitalized patients.

  6. How Regrouping Alerts in Computerized Physician Order Entry Layout Influences Physicians' Prescription Behavior: Results of a Crossover Randomized Trial.

    PubMed

    Wipfli, Rolf; Ehrler, Frederic; Bediang, Georges; Bétrancourt, Mireille; Lovis, Christian

    2016-06-02

    As demonstrated in several publications, low positive predictive value alerts in computerized physician order entry (CPOE) induce fatigue and may interrupt physicians unnecessarily during prescription of medication. Although it is difficult to increase the consideration of medical alerts by physician through an improvement of their predictive value, another approach consists to act on the way they are presented. The interruption management model inspired us to propose an alternative alert display strategy of regrouping the alerts in the screen layout, as a possible solution for reducing the interruption in physicians' workflow. In this study, we compared 2 CPOE designs based on a particular alert presentation strategy: one design involved regrouping the alerts in a single place on the screen, and in the other, the alerts were located next to the triggering information. Our objective was to evaluate experimentally whether the new design led to fewer interruptions in workflow and if it affected alert handling. The 2 CPOE designs were compared in a controlled crossover randomized trial. All interactions with the system and eye movements were stored for quantitative analysis. The study involved a group of 22 users consisting of physicians and medical students who solved medical scenarios containing prescription tasks. Scenario completion time was shorter when the alerts were regrouped (mean 117.29 seconds, SD 36.68) than when disseminated on the screen (mean 145.58 seconds, SD 75.07; P=.045). Eye tracking revealed that physicians fixated longer on alerts in the classic design (mean 119.71 seconds, SD 76.77) than in the centralized alert design (mean 70.58 seconds, SD 33.53; P=.001). Visual switches between prescription and alert areas, indicating interruption, were reduced with centralized alerts (mean 41.29, SD 21.26) compared with the classic design (mean 57.81, SD 35.97; P=.04). Prescription behavior (ie, prescription changes after alerting), however, did not change significantly between the 2 strategies of display. The After-Scenario Questionnaire (ASQ) that was filled out after each scenario showed that overall satisfaction was significantly rated lower when alerts were regrouped (mean 4.37, SD 1.23) than when displayed next to the triggering information (mean 5.32, SD 0.94; P=.02). Centralization of alerts in a table might be a way to motivate physicians to manage alerts more actively, in a meaningful way, rather than just being interrupted by them. Our study could not provide clear recommendations yet, but provides objective data through a cognitive psychological approach. Future tests should work on standardized scenarios that would enable to not only measure physicians' behavior (visual fixations and handling of alerts) but also validate those actions using clinical criteria.

  7. An Analysis of EMS and ED Detection of Stroke.

    PubMed

    Medoro, Ian; Cone, David C

    2017-01-01

    Studies have shown a reduction in time-to-CT and improved process measures when EMS personnel notify the ED of a "stroke alert" from the field. However, there are few data on the accuracy of these EMS stroke alerts. The goal of this study was to examine diagnostic test performance of EMS and ED stroke alerts and related process measures. The EMS and ED records of all stroke alerts in a large tertiary ED from August 2013-January 2014 were examined and data abstracted by one trained investigator, with data accuracy confirmed by a second investigator for 15% of cases. Stroke alerts called by EMS prior to ED arrival were compared to stroke alerts called by ED physicians and nurses (for walk-in patients, and patients transported by EMS without EMS stroke alerts). Means ± SD, medians, unpaired t-tests (for continuous data), and two-tailed Fisher's exact tests (for categorical data) were used. Of 260 consecutive stroke alerts, 129 were EMS stroke alerts, and 131 were ED stroke alerts (70 called by physicians, 61 by nurses). The mean NIH Stroke Scale was higher in the EMS group (8.1 ± 7.6 vs. 3.0 ± 5.0, p < 0.0001). The positive predictive value of EMS stroke alerts was 0.60 (78/129), alerts by ED nurses was 0.25 (15/61), and alerts by ED physicians was 0.31 (22/70). The PPV for EMS was better than for nurses or physicians (both p < 0.001), and more patients in the EMS group had final diagnoses of stroke (62/129 vs. 24/131, p < 0.001). The positive likelihood ratio was 1.53 for EMS personnel, 0.45 for physicians, and 0.77 for nurses. The mean time to order the CT (8.5 ± 7.1 min vs. 23.1 ± 18.2 min, p < 0.0001) and the mean ED length of stay (248 ± 116 min vs. 283 ± 128 min, p = 0.022) were shorter for the EMS stroke alert group. More EMS stroke alert patients received tPA (16/129 vs. 6/131, p = 0.027). EMS stroke alerts have better diagnostic test performance than stroke alerts by ED staff, likely due to higher NIH Stroke Scale scores (more obvious presentations) and are associated with better process measures. The fairly low PPV suggests room for improvement in prehospital stroke protocols.

  8. Impact of an electronic alert notification system embedded in radiologists' workflow on closed-loop communication of critical results: a time series analysis.

    PubMed

    Lacson, Ronilda; O'Connor, Stacy D; Sahni, V Anik; Roy, Christopher; Dalal, Anuj; Desai, Sonali; Khorasani, Ramin

    2016-07-01

    Optimal critical test result communication is a Joint Commission national patient safety goal and requires documentation of closed-loop communication among care providers in the medical record. Electronic alert notification systems can facilitate an auditable process for creating alerts for transmission and acknowledgement of critical test results. We evaluated the impact of a patient safety initiative with an alert notification system on reducing critical results lacking documented communication, and assessed potential overuse of the alerting system for communicating results. We implemented an alert notification system-Alert Notification of Critical Results (ANCR)-in January 2010. We reviewed radiology reports finalised in 2009-2014 which lacked documented communication between the radiologist and another care provider, and assessed the impact of ANCR on the proportion of such reports with critical findings, using trend analysis over 10 semiannual time periods. To evaluate potential overuse of ANCR, we assessed the proportion of reports with non-critical results among provider-communicated reports. The proportion of reports with critical results among reports without documented communication decreased significantly over 4 years (2009-2014) from 0.19 to 0.05 (p<0.0001, Cochran-Armitage trend test). The proportion of provider-communicated reports with non-critical results remained unchanged over time before and after ANCR implementation (0.20 to 0.15, p=0.45, Cochran-Armitage trend test). A patient safety initiative with an alert notification system reduced the proportion of critical results among reports lacking documented communication between care providers. We observed no change in documented communication of non-critical results, suggesting the system did not promote overuse. Future studies are needed to evaluate whether such systems prevent subsequent patient harm. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  9. Development of an Earthquake Impact Scale

    NASA Astrophysics Data System (ADS)

    Wald, D. J.; Marano, K. D.; Jaiswal, K. S.

    2009-12-01

    With the advent of the USGS Prompt Assessment of Global Earthquakes for Response (PAGER) system, domestic (U.S.) and international earthquake responders are reconsidering their automatic alert and activation levels as well as their response procedures. To help facilitate rapid and proportionate earthquake response, we propose and describe an Earthquake Impact Scale (EIS) founded on two alerting criteria. One, based on the estimated cost of damage, is most suitable for domestic events; the other, based on estimated ranges of fatalities, is more appropriate for most global events. Simple thresholds, derived from the systematic analysis of past earthquake impact and response levels, turn out to be quite effective in communicating predicted impact and response level of an event, characterized by alerts of green (little or no impact), yellow (regional impact and response), orange (national-scale impact and response), and red (major disaster, necessitating international response). Corresponding fatality thresholds for yellow, orange, and red alert levels are 1, 100, and 1000, respectively. For damage impact, yellow, orange, and red thresholds are triggered by estimated losses exceeding 1M, 10M, and $1B, respectively. The rationale for a dual approach to earthquake alerting stems from the recognition that relatively high fatalities, injuries, and homelessness dominate in countries where vernacular building practices typically lend themselves to high collapse and casualty rates, and it is these impacts that set prioritization for international response. In contrast, it is often financial and overall societal impacts that trigger the level of response in regions or countries where prevalent earthquake resistant construction practices greatly reduce building collapse and associated fatalities. Any newly devised alert protocols, whether financial or casualty based, must be intuitive and consistent with established lexicons and procedures. In this analysis, we make an attempt at both simple and intuitive color-coded alerting criterion; yet, we preserve the necessary uncertainty measures by which one can gauge the likelihood for the alert to be over- or underestimated.

  10. The agile alert system for gamma-ray transients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bulgarelli, A.; Trifoglio, M.; Gianotti, F.

    2014-01-20

    In recent years, a new generation of space missions has offered great opportunities for discovery in high-energy astrophysics. In this article we focus on the scientific operations of the Gamma-Ray Imaging Detector (GRID) on board the AGILE space mission. AGILE-GRID, sensitive in the energy range of 30 MeV-30 GeV, has detected many γ-ray transients of both galactic and extragalactic origin. This work presents the AGILE innovative approach to fast γ-ray transient detection, which is a challenging task and a crucial part of the AGILE scientific program. The goals are to describe (1) the AGILE Gamma-Ray Alert System, (2) a newmore » algorithm for blind search identification of transients within a short processing time, (3) the AGILE procedure for γ-ray transient alert management, and (4) the likelihood of ratio tests that are necessary to evaluate the post-trial statistical significance of the results. Special algorithms and an optimized sequence of tasks are necessary to reach our goal. Data are automatically analyzed at every orbital downlink by an alert pipeline operating on different timescales. As proper flux thresholds are exceeded, alerts are automatically generated and sent as SMS messages to cellular telephones, via e-mail, and via push notifications from an application for smartphones and tablets. These alerts are crosschecked with the results of two pipelines, and a manual analysis is performed. Being a small scientific-class mission, AGILE is characterized by optimization of both scientific analysis and ground-segment resources. The system is capable of generating alerts within two to three hours of a data downlink, an unprecedented reaction time in γ-ray astrophysics.« less

  11. The AGILE Alert System for Gamma-Ray Transients

    NASA Astrophysics Data System (ADS)

    Bulgarelli, A.; Trifoglio, M.; Gianotti, F.; Tavani, M.; Parmiggiani, N.; Fioretti, V.; Chen, A. W.; Vercellone, S.; Pittori, C.; Verrecchia, F.; Lucarelli, F.; Santolamazza, P.; Fanari, G.; Giommi, P.; Beneventano, D.; Argan, A.; Trois, A.; Scalise, E.; Longo, F.; Pellizzoni, A.; Pucella, G.; Colafrancesco, S.; Conforti, V.; Tempesta, P.; Cerone, M.; Sabatini, P.; Annoni, G.; Valentini, G.; Salotti, L.

    2014-01-01

    In recent years, a new generation of space missions has offered great opportunities for discovery in high-energy astrophysics. In this article we focus on the scientific operations of the Gamma-Ray Imaging Detector (GRID) on board the AGILE space mission. AGILE-GRID, sensitive in the energy range of 30 MeV-30 GeV, has detected many γ-ray transients of both galactic and extragalactic origin. This work presents the AGILE innovative approach to fast γ-ray transient detection, which is a challenging task and a crucial part of the AGILE scientific program. The goals are to describe (1) the AGILE Gamma-Ray Alert System, (2) a new algorithm for blind search identification of transients within a short processing time, (3) the AGILE procedure for γ-ray transient alert management, and (4) the likelihood of ratio tests that are necessary to evaluate the post-trial statistical significance of the results. Special algorithms and an optimized sequence of tasks are necessary to reach our goal. Data are automatically analyzed at every orbital downlink by an alert pipeline operating on different timescales. As proper flux thresholds are exceeded, alerts are automatically generated and sent as SMS messages to cellular telephones, via e-mail, and via push notifications from an application for smartphones and tablets. These alerts are crosschecked with the results of two pipelines, and a manual analysis is performed. Being a small scientific-class mission, AGILE is characterized by optimization of both scientific analysis and ground-segment resources. The system is capable of generating alerts within two to three hours of a data downlink, an unprecedented reaction time in γ-ray astrophysics.

  12. Tactical Conflict Detection in Terminal Airspace

    NASA Technical Reports Server (NTRS)

    Tang, Huabin; Robinson, John E.; Denery, Dallas G.

    2010-01-01

    Air traffic systems have long relied on automated short-term conflict prediction algorithms to warn controllers of impending conflicts (losses of separation). The complexity of terminal airspace has proven difficult for such systems as it often leads to excessive false alerts. Thus, the legacy system, called Conflict Alert, which provides short-term alerts in both en-route and terminal airspace currently, is often inhibited or degraded in areas where frequent false alerts occur, even though the alerts are provided only when an aircraft is in dangerous proximity of other aircraft. This research investigates how a minimal level of flight intent information may be used to improve short-term conflict detection in terminal airspace such that it can be used by the controller to maintain legal aircraft separation. The flight intent information includes a site-specific nominal arrival route and inferred altitude clearances in addition to the flight plan that includes the RNAV (Area Navigation) departure route. A new tactical conflict detection algorithm is proposed, which uses a single analytic trajectory, determined by the flight intent and the current state information of the aircraft, and includes a complex set of current, dynamic separation standards for terminal airspace to define losses of separation. The new algorithm is compared with an algorithm that imitates a known en-route algorithm and another that imitates Conflict Alert by analysis of false-alert rate and alert lead time with recent real-world data of arrival and departure operations and a large set of operational error cases from Dallas/Fort Worth TRACON (Terminal Radar Approach Control). The new algorithm yielded a false-alert rate of two per hour and an average alert lead time of 38 seconds.

  13. Investigating the association of alerts from a national mortality surveillance system with subsequent hospital mortality in England: an interrupted time series analysis.

    PubMed

    Cecil, Elizabeth; Bottle, Alex; Esmail, Aneez; Wilkinson, Samantha; Vincent, Charles; Aylin, Paul P

    2018-05-04

    To investigate the association between alerts from a national hospital mortality surveillance system and subsequent trends in relative risk of mortality. There is increasing interest in performance monitoring in the NHS. Since 2007, Imperial College London has generated monthly mortality alerts, based on statistical process control charts and using routinely collected hospital administrative data, for all English acute NHS hospital trusts. The impact of this system has not yet been studied. We investigated alerts sent to Acute National Health Service hospital trusts in England in 2011-2013. We examined risk-adjusted mortality (relative risk) for all monitored diagnosis and procedure groups at a hospital trust level for 12 months prior to an alert and 23 months post alert. We used an interrupted time series design with a 9-month lag to estimate a trend prior to a mortality alert and the change in trend after, using generalised estimating equations. On average there was a 5% monthly increase in relative risk of mortality during the 12 months prior to an alert (95% CI 4% to 5%). Mortality risk fell, on average by 61% (95% CI 56% to 65%), during the 9-month period immediately following an alert, then levelled to a slow decline, reaching on average the level of expected mortality within 18 months of the alert. Our results suggest an association between an alert notification and a reduction in the risk of mortality, although with less lag time than expected. It is difficult to determine any causal association. A proportion of alerts may be triggered by random variation alone and subsequent falls could simply reflect regression to the mean. Findings could also indicate that some hospitals are monitoring their own mortality statistics or other performance information, taking action prior to alert notification. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  14. Management of Patient-Reported Outcome (PRO) Alerts in Clinical Trials: A Cross Sectional Survey.

    PubMed

    Kyte, Derek; Ives, Jonathan; Draper, Heather; Calvert, Melanie

    2016-01-01

    Assessment of patient-reported outcomes (PROs) provides valuable information to inform patient-centered care, but may also reveal 'PRO alerts': psychological distress or physical symptoms that may require an immediate response. Ad-hoc management of PRO alerts in clinical trials may result in suboptimal patient care or potentially bias trial results. To gain greater understanding of current practice in PRO alert management we conducted a national survey of personnel involved in clinical trials with a PRO endpoint. We conducted a national cross-sectional survey of 767 UK-based research nurses, data managers/coordinators, trial managers and chief/principal investigators involved in clinical trials using PROs. Respondents were self-selected volunteers from a non-randomised sample of eligible individuals recruited via 55 UK Clinical Research Collaboration Registered Clinical Trials Units and 19 Comprehensive Local Research Networks. Questions centred on the proportion of trial personnel encountering alerts, how staff responded to PRO alerts and whether current guidance was deemed sufficient to support research personnel. We undertook descriptive analyses of the quantitative data and directed thematic analysis of free-text comments. 20% of research nurses did not view completed PRO questionnaires and were not in a position to discover alerts, 39-50% of the remaining respondent group participants reported encountering PRO alerts. Of these, 83% of research nurses and 54% of data managers/trial coordinators reported taking action to assist the trial participant, but less than half were able to record the intervention in the trial documentation. Research personnel reported current PRO alert guidance/training was insufficient. Research personnel are intermittently exposed to PRO alerts. Some intervene to help trial participants, but are not able to record this intervention in the trial documentation, risking co-intervention bias. Other staff do not check PRO information during the trial, meaning alerts may remain undiscovered, or do not respond to alerts if they are inadvertently encountered; both of which may impact on patient safety. Guidance is needed to support PRO alert management that protects the interests of trial participants whilst avoiding potential bias.

  15. The Use of Non-Standard Devices in Finite Element Analysis

    NASA Technical Reports Server (NTRS)

    Schur, Willi W.; Broduer, Steve (Technical Monitor)

    2001-01-01

    A general mathematical description of the response behavior of thin-skin pneumatic envelopes and many other membrane and cable structures produces under-constrained systems that pose severe difficulties to analysis. These systems are mobile, and the general mathematical description exposes the mobility. Yet the response behavior of special under-constrained structures under special loadings can be accurately predicted using a constrained mathematical description. The static response behavior of systems that are infinitesimally mobile, such as a non-slack membrane subtended from a rigid or elastic boundary frame, can be easily analyzed using such general mathematical description as afforded by the non-linear, finite element method using an implicit solution scheme if the incremental uploading is guided through a suitable path. Similarly, if such structures are assembled with structural lack of fit that provides suitable self-stress, then dynamic response behavior can be predicted by the non-linear, finite element method and an implicit solution scheme. An explicit solution scheme is available for evolution problems. Such scheme can be used via the method of dynamic relaxation to obtain the solution to a static problem. In some sense, pneumatic envelopes and many other compliant structures can be said to have destiny under a specified loading system. What that means to the analyst is that what happens on the evolution path of the solution is irrelevant as long as equilibrium is achieved at destiny under full load and that the equilibrium is stable in the vicinity of that load. The purpose of this paper is to alert practitioners to the fact that non-standard procedures in finite element analysis are useful and can be legitimate although they burden their users with the requirement to use special caution. Some interesting findings that are useful to the US Scientific Balloon Program and that could not be obtained without non-standard techniques are presented.

  16. An evidence- and risk-based approach to a harmonized laboratory alert list in Australia and New Zealand.

    PubMed

    Campbell, Craig A; Lam, Que; Horvath, Andrea R

    2018-04-19

    Individual laboratories are required to compose an alert list for identifying critical and significant risk results. The high-risk result working party of the Royal College of Pathologists of Australasia (RCPA) and the Australasian Association of Clinical Biochemists (AACB) has developed a risk-based approach for a harmonized alert list for laboratories throughout Australia and New Zealand. The six-step process for alert threshold identification and assessment involves reviewing the literature, rating the available evidence, performing a risk analysis, assessing method transferability, considering workload implications and seeking endorsement from stakeholders. To demonstrate this approach, a worked example for deciding the upper alert threshold for potassium is described. The findings of the worked example are for infants aged 0-6 months, a recommended upper potassium alert threshold of >7.0 mmol/L in serum and >6.5 mmol/L in plasma, and for individuals older than 6 months, a threshold of >6.2 mmol/L in both serum and plasma. Limitations in defining alert thresholds include the lack of well-designed studies that measure the relationship between high-risk results and patient outcomes or the benefits of treatment to prevent harm, and the existence of a wide range of clinical practice guidelines with conflicting decision points at which treatment is required. The risk-based approach described presents a transparent, evidence- and consensus-based methodology that can be used by any laboratory when designing an alert list for local use. The RCPA-AACB harmonized alert list serves as a starter set for further local adaptation or adoption after consultation with clinical users.

  17. Climatological Study to Determine the Impact of Icing on the Low Level Windshear Alert System. Volume I. Analysis.

    DOT National Transportation Integrated Search

    1989-09-01

    The climatological study was performed to determine the impact of icing on the performance of Low Level Windshear Alert System (LLWAS). : This report presents the icing statistical profile in the form of data tables and histograms of 106 LLWAS sites....

  18. RED Alert – Early warning or detection of global re-emerging infectious disease (RED)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deshpande, Alina

    This is the PDF of a presentation for a webinar given by Los Alamos National Laboratory (LANL) on the early warning or detection of global re-emerging infectious disease (RED). First, there is an overview of LANL biosurveillance tools. Then, information is given about RED Alert. Next, a demonstration is given of a component prototype. RED Alert is an analysis tool that can provide early warning or detection of the re-emergence of an infectious disease at the global level, but through a local lens.

  19. An Enhanced Secure Identity-Based Certificateless Public Key Authentication Scheme for Vehicular Sensor Networks

    PubMed Central

    Li, Congcong; Zhang, Xi; Wang, Haiping; Li, Dongfeng

    2018-01-01

    Vehicular sensor networks have been widely applied in intelligent traffic systems in recent years. Because of the specificity of vehicular sensor networks, they require an enhanced, secure and efficient authentication scheme. Existing authentication protocols are vulnerable to some problems, such as a high computational overhead with certificate distribution and revocation, strong reliance on tamper-proof devices, limited scalability when building many secure channels, and an inability to detect hardware tampering attacks. In this paper, an improved authentication scheme using certificateless public key cryptography is proposed to address these problems. A security analysis of our scheme shows that our protocol provides an enhanced secure anonymous authentication, which is resilient against major security threats. Furthermore, the proposed scheme reduces the incidence of node compromise and replication attacks. The scheme also provides a malicious-node detection and warning mechanism, which can quickly identify compromised static nodes and immediately alert the administrative department. With performance evaluations, the scheme can obtain better trade-offs between security and efficiency than the well-known available schemes. PMID:29324719

  20. A radar-based regional extreme rainfall analysis to derive the thresholds for a novel automatic alert system in Switzerland

    NASA Astrophysics Data System (ADS)

    Panziera, Luca; Gabella, Marco; Zanini, Stefano; Hering, Alessandro; Germann, Urs; Berne, Alexis

    2016-06-01

    This paper presents a regional extreme rainfall analysis based on 10 years of radar data for the 159 regions adopted for official natural hazard warnings in Switzerland. Moreover, a nowcasting tool aimed at issuing heavy precipitation regional alerts is introduced. The two topics are closely related, since the extreme rainfall analysis provides the thresholds used by the nowcasting system for the alerts. Warm and cold seasons' monthly maxima of several statistical quantities describing regional rainfall are fitted to a generalized extreme value distribution in order to derive the precipitation amounts corresponding to sub-annual return periods for durations of 1, 3, 6, 12, 24 and 48 h. It is shown that regional return levels exhibit a large spatial variability in Switzerland, and that their spatial distribution strongly depends on the duration of the aggregation period: for accumulations of 3 h and shorter, the largest return levels are found over the northerly alpine slopes, whereas for longer durations the southern Alps exhibit the largest values. The inner alpine chain shows the lowest values, in agreement with previous rainfall climatologies. The nowcasting system presented here is aimed to issue heavy rainfall alerts for a large variety of end users, who are interested in different precipitation characteristics and regions, such as, for example, small urban areas, remote alpine catchments or administrative districts. The alerts are issued not only if the rainfall measured in the immediate past or forecast in the near future exceeds some predefined thresholds but also as soon as the sum of past and forecast precipitation is larger than threshold values. This precipitation total, in fact, has primary importance in applications for which antecedent rainfall is as important as predicted one, such as urban floods early warning systems. The rainfall fields, the statistical quantity representing regional rainfall and the frequency of alerts issued in case of continuous threshold exceedance are some of the configurable parameters of the tool. The analysis of the urban flood which occurred in the city of Schaffhausen in May 2013 suggests that this alert tool might have complementary skill with respect to radar-based thunderstorm nowcasting systems for storms which do not show a clear convective signature.

  1. Exploring the heavy air pollution in Beijing in the fourth quarter of 2015: assessment of environmental benefits for red alerts

    NASA Astrophysics Data System (ADS)

    Nie, Teng; Nie, Lei; Zhou, Zhen; Wang, Zhanshan; Xue, Yifeng; Gao, Jiajia; Wu, Xiaoqing; Fan, Shoubin; Cheng, Linglong

    2018-06-01

    In recent years, Beijing has experienced severe air pollution which has caused widespread public concern. Compared to the same period in 2014, the first three quarters of 2015 exhibited significantly improved air quality. However, the air quality sharply declined in the fourth quarter of 2015, especially in November and December. During that time, Beijing issued the first red alert for severe air pollution in history. In total, 2 red alerts, 3 orange alerts, 3 yellow alerts, and 3 blue alerts were issued based on the adoption of relatively temporary emergency control measures to mitigate air pollution. This study explored the reasons for these variations in air quality and assessed the effectiveness of emergency alerts in addressing severe air pollution. A synthetic analysis of emission variations and meteorological conditions was performed to better understand these extreme air pollution episodes in the fourth quarter of 2015. The results showed that compared to those in the same period in 2014, the daily average emissions of air pollutants decreased in the fourth quarter of 2015. However, the emission levels of primary pollutants were still relatively high, which was the main intrinsic cause of haze episodes, and unfavorable meteorological conditions represented important external factors. Emergency control measures for heavy air pollution were implemented during this red alert period, decreasing the emissions of primary air pollutants by approximately 36% and the PM2.5 concentration by 11%‒21%.

  2. Advantages and Disadvantages of Educational Email Alerts for Family Physicians: Viewpoint

    PubMed Central

    Badran, Hani; Grad, Roland

    2015-01-01

    Background Electronic knowledge resources constitute an important channel for accredited Continuing Medical Education (CME) activities. However, email usage for educational purposes is controversial. On the one hand, family physicians become aware of new information, confirm what they already know, and obtain reassurance by reading educational email alerts. Email alerts can also encourage physicians to search Web-based resources. On the other hand, technical difficulties and privacy issues are common obstacles. Objective The purpose of this discussion paper, informed by a literature review and a small qualitative study, was to understand family physicians’ knowledge, attitudes, and behavior in regard to email in general and educational emails in particular, and to explore the advantages and disadvantages of educational email alerts. In addition, we documented participants’ suggestions to improve email alert services for CME. Methods We conducted a qualitative descriptive study using the “Knowledge, Attitude, Behavior” model. We conducted semi-structured face-to-face interviews with 15 family physicians. We analyzed the collected data using inductive-deductive thematic qualitative data analysis. Results All 15 participants scanned and prioritized their email, and 13 of them checked their email daily. Participants mentioned (1) advantages of educational email alerts such as saving time, convenience and valid information, and (2) disadvantages such as an overwhelming number of emails and irrelevance. They offered suggestions to improve educational email. Conclusions The advantages of email alerts seem to compensate for their disadvantages. Suggestions proposed by family physicians can help to improve educational email alerts. PMID:25803184

  3. Advantages and disadvantages of educational email alerts for family physicians: viewpoint.

    PubMed

    Badran, Hani; Pluye, Pierre; Grad, Roland

    2015-02-27

    Electronic knowledge resources constitute an important channel for accredited Continuing Medical Education (CME) activities. However, email usage for educational purposes is controversial. On the one hand, family physicians become aware of new information, confirm what they already know, and obtain reassurance by reading educational email alerts. Email alerts can also encourage physicians to search Web-based resources. On the other hand, technical difficulties and privacy issues are common obstacles. The purpose of this discussion paper, informed by a literature review and a small qualitative study, was to understand family physicians' knowledge, attitudes, and behavior in regard to email in general and educational emails in particular, and to explore the advantages and disadvantages of educational email alerts. In addition, we documented participants' suggestions to improve email alert services for CME. We conducted a qualitative descriptive study using the "Knowledge, Attitude, Behavior" model. We conducted semi-structured face-to-face interviews with 15 family physicians. We analyzed the collected data using inductive-deductive thematic qualitative data analysis. All 15 participants scanned and prioritized their email, and 13 of them checked their email daily. Participants mentioned (1) advantages of educational email alerts such as saving time, convenience and valid information, and (2) disadvantages such as an overwhelming number of emails and irrelevance. They offered suggestions to improve educational email. The advantages of email alerts seem to compensate for their disadvantages. Suggestions proposed by family physicians can help to improve educational email alerts.

  4. Comparison of warfarin therapy clinical outcomes following implementation of an automated mobile phone-based critical laboratory value text alert system.

    PubMed

    Lin, Shu-Wen; Kang, Wen-Yi; Lin, Dong-Tsamn; Lee, James; Wu, Fe-Lin; Chen, Chuen-Liang; Tseng, Yufeng J

    2014-01-01

    Computerized alert and reminder systems have been widely accepted and applied to various patient care settings, with increasing numbers of clinical laboratories communicating critical laboratory test values to professionals via either manual notification or automated alerting systems/computerized reminders. Warfarin, an oral anticoagulant, exhibits narrow therapeutic range between treatment response and adverse events. It requires close monitoring of prothrombin time (PT)/international normalized ratio (INR) to ensure patient safety. This study was aimed to evaluate clinical outcomes of patients on warfarin therapy following implementation of a Personal Handy-phone System-based (PHS) alert system capable of generating and delivering text messages to communicate critical PT/INR laboratory results to practitioners' mobile phones in a large tertiary teaching hospital. A retrospective analysis was performed comparing patient clinical outcomes and physician prescribing behavior following conversion from a manual laboratory result alert system to an automated system. Clinical outcomes and practitioner responses to both alert systems were compared. Complications to warfarin therapy, warfarin utilization, and PT/INR results were evaluated for both systems, as well as clinician time to read alert messages, time to warfarin therapy modification, and monitoring frequency. No significant differences were detected in major hemorrhage and thromboembolism, warfarin prescribing patterns, PT/INR results, warfarin therapy modification, or monitoring frequency following implementation of the PHS text alert system. In both study periods, approximately 80% of critical results led to warfarin discontinuation or dose reduction. Senior physicians' follow-up response time to critical results was significantly decreased in the PHS alert study period (46.3% responded within 1 day) compared to the manual notification study period (24.7%; P = 0.015). No difference in follow-up response time was detected for junior physicians. Implementation of an automated PHS-based text alert system did not adversely impact clinical or safety outcomes of patients on warfarin therapy. Approximately 80% immediate recognition of text alerts was achieved. The potential benefits of an automated PHS alert for senior physicians were demonstrated.

  5. Evidence of effects of human disturbance on alert response in Père David's deer (Elaphurus davidianus).

    PubMed

    Li, Chunwang; Jiang, Zhigang; Tang, Songhua; Zeng, Yan

    2007-11-01

    To understand effects of human disturbance on alert response of Père David's deer, we carried out an experiment in the Dafeng Père David's Deer Reserve (32 degrees 59'-33 degrees 03'N, 120 degrees 47'-120 degrees 53'E), China. In the spring and summer, we observed alert responses (including stare, walking away, and flee) of deer and recorded the intensity of tourist disturbance in a small display pen using a laser-range finder to measure the alert distance of a free-ranging group in a large enclosure. We also recorded the pattern of head orientation when deer were resting in these two deer groups. After statistical analysis, we found that: 1) in small pen, the frequency of alert response was significantly different among different intensities of human disturbance; strong disturbance resulted in higher frequency of alert response; 2) stare distance in the free-ranging group in summer was significantly longer than that in spring, but the distance of walking away and the distance of flee showed no significant difference between the two seasons; and 3) in free-ranging group, there was no significant directional difference in head orientation, whereas in display group, there was a significant directional difference in head orientation. We suggest that: 1) under the captive situation, human disturbance may be one of the factors that affect alert response in Père David's deer; and 2) Père David's deer adopted different alert response to adapt to human disturbance under different circumstance. We recommended that relationships between alert response and human disturbance should be considered in ex situ conservation of this field extinct deer. Zoo Biol 26:461-470, 2007. (c) 2007 Wiley-Liss, Inc.

  6. Physicians’ use of computerized clinical decision supports to improve medication management in the elderly – the Seniors Medication Alert and Review Technology intervention

    PubMed Central

    Alagiakrishnan, Kannayiram; Wilson, Patricia; Sadowski, Cheryl A; Rolfson, Darryl; Ballermann, Mark; Ausford, Allen; Vermeer, Karla; Mohindra, Kunal; Romney, Jacques; Hayward, Robert S

    2016-01-01

    Background Elderly people (aged 65 years or more) are at increased risk of polypharmacy (five or more medications), inappropriate medication use, and associated increased health care costs. The use of clinical decision support (CDS) within an electronic medical record (EMR) could improve medication safety. Methods Participatory action research methods were applied to preproduction design and development and postproduction optimization of an EMR-embedded CDS implementation of the Beers’ Criteria for medication management and the Cockcroft–Gault formula for estimating glomerular filtration rates (GFR). The “Seniors Medication Alert and Review Technologies” (SMART) intervention was used in primary care and geriatrics specialty clinics. Passive (chart messages) and active (order-entry alerts) prompts exposed potentially inappropriate medications, decreased GFR, and the possible need for medication adjustments. Physician reactions were assessed using surveys, EMR simulations, focus groups, and semi-structured interviews. EMR audit data were used to identify eligible patient encounters, the frequency of CDS events, how alerts were managed, and when evidence links were followed. Results Analysis of subjective data revealed that most clinicians agreed that CDS appeared at appropriate times during patient care. Although managing alerts incurred a modest time burden, most also agreed that workflow was not disrupted. Prevalent concerns related to clinician accountability and potential liability. Approximately 36% of eligible encounters triggered at least one SMART alert, with GFR alert, and most frequent medication warnings were with hypnotics and anticholinergics. Approximately 25% of alerts were overridden and ~15% elicited an evidence check. Conclusion While most SMART alerts validated clinician choices, they were received as valuable reminders for evidence-informed care and education. Data from this study may aid other attempts to implement Beers’ Criteria in ambulatory care EMRs. PMID:26869776

  7. Sensitivity and specificity of dosing alerts for dosing errors among hospitalized pediatric patients

    PubMed Central

    Stultz, Jeremy S; Porter, Kyle; Nahata, Milap C

    2014-01-01

    Objectives To determine the sensitivity and specificity of a dosing alert system for dosing errors and to compare the sensitivity of a proprietary system with and without institutional customization at a pediatric hospital. Methods A retrospective analysis of medication orders, orders causing dosing alerts, reported adverse drug events, and dosing errors during July, 2011 was conducted. Dosing errors with and without alerts were identified and the sensitivity of the system with and without customization was compared. Results There were 47 181 inpatient pediatric orders during the studied period; 257 dosing errors were identified (0.54%). The sensitivity of the system for identifying dosing errors was 54.1% (95% CI 47.8% to 60.3%) if customization had not occurred and increased to 60.3% (CI 54.0% to 66.3%) with customization (p=0.02). The sensitivity of the system for underdoses was 49.6% without customization and 60.3% with customization (p=0.01). Specificity of the customized system for dosing errors was 96.2% (CI 96.0% to 96.3%) with a positive predictive value of 8.0% (CI 6.8% to 9.3). All dosing errors had an alert over-ridden by the prescriber and 40.6% of dosing errors with alerts were administered to the patient. The lack of indication-specific dose ranges was the most common reason why an alert did not occur for a dosing error. Discussion Advances in dosing alert systems should aim to improve the sensitivity and positive predictive value of the system for dosing errors. Conclusions The dosing alert system had a low sensitivity and positive predictive value for dosing errors, but might have prevented dosing errors from reaching patients. Customization increased the sensitivity of the system for dosing errors. PMID:24496386

  8. Does Telehealth Monitoring Identify Exacerbations of Chronic Obstructive Pulmonary Disease and Reduce Hospitalisations? An Analysis of System Data

    PubMed Central

    Bentley, Claire L; Mountain, Gail A

    2017-01-01

    Background The increasing prevalence and associated cost of treating chronic obstructive pulmonary disease (COPD) is unsustainable. Health care organizations are focusing on ways to support self-management and prevent hospital admissions, including telehealth-monitoring services capturing physiological and health status data. This paper reports on data captured during a pilot randomized controlled trial of telehealth-supported care within a community-based service for patients discharged from hospital following an exacerbation of their COPD. Objective The aim was to undertake the first analysis of system data to determine whether telehealth monitoring can identify an exacerbation of COPD, providing clinicians with an opportunity to intervene with timely treatment and prevent hospital readmission. Methods A total of 23 participants received a telehealth-supported intervention. This paper reports on the analysis of data from a telehealth monitoring system that captured data from two sources: (1) data uploaded both manually and using Bluetooth peripheral devices by the 23 participants and (2) clinical records entered as nursing notes by the clinicians. Rules embedded in the telehealth monitoring system triggered system alerts to be reviewed by remote clinicians who determined whether clinical intervention was required. We also analyzed data on the frequency and length (bed days) of hospital admissions, frequency of hospital Accident and Emergency visits that did not lead to hospital admission, and frequency and type of community health care service contacts—other than the COPD discharge service—for all participants for the duration of the intervention and 6 months postintervention. Results Patients generated 512 alerts, 451 of which occurred during the first 42 days that all participants used the equipment. Patients generated fewer alerts over time with typically seven alerts per day within the first 10 days and four alerts per day thereafter. They also had three times more days without alerts than with alerts. Alerts were most commonly triggered by reports of being more tired, having difficulty with self-care, and blood pressure being out of range. During the 8-week intervention, and for 6-month follow-up, eight of the 23 patients were hospitalized. Hospital readmission rates (2/23, 9%) in the first 28 days of service were lower than the 20% UK norm. Conclusions It seems that the clinical team can identify exacerbations based on both an increase in alerts and the types of system-generated alerts as evidenced by their efforts to provided treatment interventions. There was some indication that telehealth monitoring potentially delayed hospitalizations until after patients had been discharged from the service. We suggest that telehealth-supported care can fulfill an important role in enabling patients with COPD to better manage their condition and remain out of hospital, but adequate resourcing and timely response to alerts is a critical factor in supporting patients to remain at home. Trial Registration International Standard Randomized Controlled Trial Number (ISRCTN): 68856013; http://www.isrctn.com/ISRCTN68856013 (Archived by WebCite at http://www.webcitation.org/6ofApNB2e) PMID:28330829

  9. A Comparative Analysis of the Snort and Suricata Intrusion-Detection Systems

    DTIC Science & Technology

    2011-09-01

    Category: Test Rules Test #6: Simple LFI Attack 43 Snort True Positive: Snort generated an alert based on the ‘/etc/ passwd ’ string passed...through an HTTP command. Suricata True Positive: Suricata generated an alert based on the ‘/etc/ passwd ’ string passed through an HTTP command

  10. Real-Time Mapping alert system; user's manual

    USGS Publications Warehouse

    Torres, L.A.

    1996-01-01

    The U.S. Geological Survey has an extensive hydrologic network that records and transmits precipitation, stage, discharge, and other water- related data on a real-time basis to an automated data processing system. Data values are recorded on electronic data collection platforms at field monitoring sites. These values are transmitted by means of orbiting satellites to receiving ground stations, and by way of telecommunication lines to a U.S. Geological Survey office where they are processed on a computer system. Data that exceed predefined thresholds are identified as alert values. These alert values can help keep water- resource specialists informed of current hydrologic conditions. The current alert status at monitoring sites is of critical importance during floods, hurricanes, and other extreme hydrologic events where quick analysis of the situation is needed. This manual provides instructions for using the Real-Time Mapping software, a series of computer programs developed by the U.S. Geological Survey for quick analysis of hydrologic conditions, and guides users through a basic interactive session. The software provides interactive graphics display and query of real-time information in a map-based, menu-driven environment.

  11. Clinical decision support alert malfunctions: analysis and empirically derived taxonomy.

    PubMed

    Wright, Adam; Ai, Angela; Ash, Joan; Wiesen, Jane F; Hickman, Thu-Trang T; Aaron, Skye; McEvoy, Dustin; Borkowsky, Shane; Dissanayake, Pavithra I; Embi, Peter; Galanter, William; Harper, Jeremy; Kassakian, Steve Z; Ramoni, Rachel; Schreiber, Richard; Sirajuddin, Anwar; Bates, David W; Sittig, Dean F

    2018-05-01

    To develop an empirically derived taxonomy of clinical decision support (CDS) alert malfunctions. We identified CDS alert malfunctions using a mix of qualitative and quantitative methods: (1) site visits with interviews of chief medical informatics officers, CDS developers, clinical leaders, and CDS end users; (2) surveys of chief medical informatics officers; (3) analysis of CDS firing rates; and (4) analysis of CDS overrides. We used a multi-round, manual, iterative card sort to develop a multi-axial, empirically derived taxonomy of CDS malfunctions. We analyzed 68 CDS alert malfunction cases from 14 sites across the United States with diverse electronic health record systems. Four primary axes emerged: the cause of the malfunction, its mode of discovery, when it began, and how it affected rule firing. Build errors, conceptualization errors, and the introduction of new concepts or terms were the most frequent causes. User reports were the predominant mode of discovery. Many malfunctions within our database caused rules to fire for patients for whom they should not have (false positives), but the reverse (false negatives) was also common. Across organizations and electronic health record systems, similar malfunction patterns recurred. Challenges included updates to code sets and values, software issues at the time of system upgrades, difficulties with migration of CDS content between computing environments, and the challenge of correctly conceptualizing and building CDS. CDS alert malfunctions are frequent. The empirically derived taxonomy formalizes the common recurring issues that cause these malfunctions, helping CDS developers anticipate and prevent CDS malfunctions before they occur or detect and resolve them expediently.

  12. Earthquake impact scale

    USGS Publications Warehouse

    Wald, D.J.; Jaiswal, K.S.; Marano, K.D.; Bausch, D.

    2011-01-01

    With the advent of the USGS prompt assessment of global earthquakes for response (PAGER) system, which rapidly assesses earthquake impacts, U.S. and international earthquake responders are reconsidering their automatic alert and activation levels and response procedures. To help facilitate rapid and appropriate earthquake response, an Earthquake Impact Scale (EIS) is proposed on the basis of two complementary criteria. On the basis of the estimated cost of damage, one is most suitable for domestic events; the other, on the basis of estimated ranges of fatalities, is generally more appropriate for global events, particularly in developing countries. Simple thresholds, derived from the systematic analysis of past earthquake impact and associated response levels, are quite effective in communicating predicted impact and response needed after an event through alerts of green (little or no impact), yellow (regional impact and response), orange (national-scale impact and response), and red (international response). Corresponding fatality thresholds for yellow, orange, and red alert levels are 1, 100, and 1,000, respectively. For damage impact, yellow, orange, and red thresholds are triggered by estimated losses reaching $1M, $100M, and $1B, respectively. The rationale for a dual approach to earthquake alerting stems from the recognition that relatively high fatalities, injuries, and homelessness predominate in countries in which local building practices typically lend themselves to high collapse and casualty rates, and these impacts lend to prioritization for international response. In contrast, financial and overall societal impacts often trigger the level of response in regions or countries in which prevalent earthquake resistant construction practices greatly reduce building collapse and resulting fatalities. Any newly devised alert, whether economic- or casualty-based, should be intuitive and consistent with established lexicons and procedures. Useful alerts should also be both specific (although allowably uncertain) and actionable. In this analysis, an attempt is made at both simple and intuitive color-coded alerting criteria; yet the necessary uncertainty measures by which one can gauge the likelihood for the alert to be over- or underestimated are preserved. The essence of the proposed impact scale and alerting is that actionable loss information is now available in the immediate aftermath of significant earthquakes worldwide on the basis of quantifiable loss estimates. Utilizing EIS, PAGER's rapid loss estimates can adequately recommend alert levels and suggest appropriate response protocols, despite the uncertainties; demanding or awaiting observations or loss estimates with a high level of accuracy may increase the losses. ?? 2011 American Society of Civil Engineers.

  13. Parts, Materials, and Processes Experience Summary. Volume 1; [Catalog of ALERT and Other Information on Basic Design, Reliability, Quality and Applications Programs

    NASA Technical Reports Server (NTRS)

    1973-01-01

    The ALERT program, a system for communicating common problems with parts, materials, and processes, is condensed and catalogued. Expanded information on selected topics is provided by relating the problem area (failure) to the cause, the investigations and findings, the suggestions for avoidance (inspections, screening tests, proper part applications), and failure analysis procedures. The basic objective of ALERT is the avoidance of the recurrence of parts, materials, and processed problems, thus improving the reliability of equipment produced for and used by the government.

  14. Static Analysis Using Abstract Interpretation

    NASA Technical Reports Server (NTRS)

    Arthaud, Maxime

    2017-01-01

    Short presentation about static analysis and most particularly abstract interpretation. It starts with a brief explanation on why static analysis is used at NASA. Then, it describes the IKOS (Inference Kernel for Open Static Analyzers) tool chain. Results on NASA projects are shown. Several well known algorithms from the static analysis literature are then explained (such as pointer analyses, memory analyses, weak relational abstract domains, function summarization, etc.). It ends with interesting problems we encountered (such as C++ analysis with exception handling, or the detection of integer overflow).

  15. EEG quantification of alertness: methods for early identification of individuals most susceptible to sleep deprivation

    NASA Astrophysics Data System (ADS)

    Berka, Chris; Levendowski, Daniel J.; Westbrook, Philip; Davis, Gene; Lumicao, Michelle N.; Olmstead, Richard E.; Popovic, Miodrag; Zivkovic, Vladimir T.; Ramsey, Caitlin K.

    2005-05-01

    Electroencephalographic (EEG) and neurocognitive measures were simultaneously acquired to quantify alertness from 24 participants during 44-hours of sleep deprivation. Performance on a three-choice vigilance task (3C-VT), paired-associate learning/memory task (PAL) and modified Maintenance of Wakefulness Test (MWT), and sleep technician-observed drowsiness (eye-closures, head-nods, EEG slowing) were quantified. The B-Alert system automatically classifies each second of EEG on an alertness/drowsiness continuum. B-Alert classifications were significantly correlated with technician-observations, visually scored EEG and performance measures. B-Alert classifications during 3C-VT, and technician observations and performance during the 3C-VT and PAL evidenced progressively increasing drowsiness as a result of sleep deprivation with a stabilizing effect observed at the batteries occurring between 0600 and 1100 suggesting a possible circadian effect similar to those reported in previous sleep deprivation studies. Participants were given an opportunity to take a 40-minute nap approximately 24-hours into the sleep deprivation portion of the study (i.e., 7 PM on Saturday). The nap was followed by a transient period of increased alertness. Approximately 8 hours after the nap, behavioral and physiological measures of drowsiness returned to levels prior to the nap. Cluster analysis was used to stratify individuals into three groups based on their level of impairment as a result of sleep deprivation. The combination of B-Alert and neuro-behavioral measures may identify individuals whose performance is most susceptible to sleep deprivation. These objective measures could be applied in an operational setting to provide a "biobehavioral assay" to determine vulnerability to sleep deprivation.

  16. LINEBACKER: LINE-speed Bio-inspired Analysis and Characterization for Event Recognition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oehmen, Christopher S.; Bruillard, Paul J.; Matzke, Brett D.

    2016-08-04

    The cyber world is a complex domain, with digital systems mediating a wide spectrum of human and machine behaviors. While this is enabling a revolution in the way humans interact with each other and data, it also is exposing previously unreachable infrastructure to a worldwide set of actors. Existing solutions for intrusion detection and prevention that are signature-focused typically seek to detect anomalous and/or malicious activity for the sake of preventing or mitigating negative impacts. But a growing interest in behavior-based detection is driving new forms of analysis that move the emphasis from static indicators (e.g. rule-based alarms or tripwires)more » to behavioral indicators that accommodate a wider contextual perspective. Similar to cyber systems, biosystems have always existed in resource-constrained hostile environments where behaviors are tuned by context. So we look to biosystems as an inspiration for addressing behavior-based cyber challenges. In this paper, we introduce LINEBACKER, a behavior-model based approach to recognizing anomalous events in network traffic and present the design of this approach of bio-inspired and statistical models working in tandem to produce individualized alerting for a collection of systems. Preliminary results of these models operating on historic data are presented along with a plugin to support real-world cyber operations.« less

  17. 21 CFR Appendix E to Subpart A of... - Elements To Be Considered in Developing a Two-Way Alert System

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... hazards evaluation and classification —Language of communication and transmission of information 2. Crisis Management System —Crisis analysis and communication mechanisms —Establishment of contact points —Reporting... Considered in Developing a Two-Way Alert System 1. Documentation —Definition of a crisis/emergency and under...

  18. Terminal - Tactical Separation Assured Flight Environment (T-TSafe)

    NASA Technical Reports Server (NTRS)

    Verma, Savita Arora; Tang, Huabin; Ballinger, Debbi

    2011-01-01

    The Tactical Separation Assured Flight Environment (TSAFE) has been previously tested as a conflict detection and resolution tool in the en-route phase of flight. Fast time simulations of a terminal version of this tool called Terminal TSAFE (T-TSAFE) have shown promise over the current conflict detection tools. It has shown to have fewer false alerts (as low as 2 per hour) and better prediction to conflict time than Conflict Alert. The tool will be tested in the simulated terminal area of Los Angeles International Airport, in a Human-in-the-loop experiment to identify controller procedures and information requirements. The simulation will include comparisons of T-TSAFE with NASA's version of Conflict Alert. Also, some other variables such as altitude entry by the controller, which improve T-TSAFE's predictions for conflict detection, will be tested. T-TSAFE integrates features of current conflict detection tools such as Automated Terminal Proximity Alert used to alleviate compression errors in the final approach phase. Based on fast-time simulation analysis, the anticipated benefits of T-TSAFE over Conflict Alert include reduced false/missed alerts and increased time to predicted loss of separation. Other metrics that will be used to evaluate the tool's impact on the controller include controller intervention, workload, and situation awareness.

  19. Foodborne Norovirus State of Affairs in the EU Rapid Alert System for Food and Feed

    PubMed Central

    Papapanagiotou, Elias P.

    2017-01-01

    The European Union Rapid Alert System for Food and Feed (EU RASFF) database is an invaluable instrument for analyzing notifications involving norovirus in food. The aim of this work was to carry out a thorough research of the alert and border rejection notifications submitted in the RASFF database from its onset until 31 August 2017. Some conclusions of interest were: (i) Denmark, France, Italy, the Netherlands and Norway have contributed the majority of alert notifications as notifying countries, (ii) France and Serbia have been cited more often in alert notifications as countries of origin, (iii) Italy and Spain have submitted the majority of border rejection notifications, (iv) Third Countries implicated more frequently in border rejection notifications for norovirus in bivalve molluscs were Vietnam and Tunisia, whereas in fruits and vegetables were China and Serbia, (v) “risk dispersion” from norovirus-contaminated food was narrow since, in just over half of all alert notifications and all of the border rejection notifications, only up to three countries were involved, and (vi) both raw (oysters and berries) and cooked (mussels) food products can present a health risk to consumers. The information retrieved from the RASFF database on norovirus-contaminated food could prove helpful in the planning of future norovirus risk analysis endeavors. PMID:29186840

  20. CISN ShakeAlert Earthquake Early Warning System Monitoring Tools

    NASA Astrophysics Data System (ADS)

    Henson, I. H.; Allen, R. M.; Neuhauser, D. S.

    2015-12-01

    CISN ShakeAlert is a prototype earthquake early warning system being developed and tested by the California Integrated Seismic Network. The system has recently been expanded to support redundant data processing and communications. It now runs on six machines at three locations with ten Apache ActiveMQ message brokers linking together 18 waveform processors, 12 event association processes and 4 Decision Module alert processes. The system ingests waveform data from about 500 stations and generates many thousands of triggers per day, from which a small portion produce earthquake alerts. We have developed interactive web browser system-monitoring tools that display near real time state-of-health and performance information. This includes station availability, trigger statistics, communication and alert latencies. Connections to regional earthquake catalogs provide a rapid assessment of the Decision Module hypocenter accuracy. Historical performance can be evaluated, including statistics for hypocenter and origin time accuracy and alert time latencies for different time periods, magnitude ranges and geographic regions. For the ElarmS event associator, individual earthquake processing histories can be examined, including details of the transmission and processing latencies associated with individual P-wave triggers. Individual station trigger and latency statistics are available. Detailed information about the ElarmS trigger association process for both alerted events and rejected events is also available. The Google Web Toolkit and Map API have been used to develop interactive web pages that link tabular and geographic information. Statistical analysis is provided by the R-Statistics System linked to a PostgreSQL database.

  1. Impact of an emergency department electronic sepsis surveillance system on patient mortality and length of stay.

    PubMed

    Austrian, Jonathan S; Jamin, Catherine T; Doty, Glenn R; Blecker, Saul

    2018-05-01

    The purpose of this study was to determine whether an electronic health record-based sepsis alert system could improve quality of care and clinical outcomes for patients with sepsis. We performed a patient-level interrupted time series study of emergency department patients with severe sepsis or septic shock between January 2013 and April 2015. The intervention, introduced in February 2014, was a system of interruptive sepsis alerts triggered by abnormal vital signs or laboratory results. Primary outcomes were length of stay (LOS) and in-hospital mortality; other outcomes included time to first lactate and blood cultures prior to antibiotics. We also assessed sensitivity, positive predictive value (PPV), and clinician response to the alerts. Mean LOS for patients with sepsis decreased from 10.1 to 8.6 days (P < .001) following alert introduction. In adjusted time series analysis, the intervention was associated with a decreased LOS of 16% (95% CI, 5%-25%; P = .007, with significance of α = 0.006) and no change thereafter (0%; 95% CI, -2%, 2%). The sepsis alert system had no effect on mortality or other clinical or process measures. The intervention had a sensitivity of 80.4% and a PPV of 14.6%. Alerting based on simple laboratory and vital sign criteria was insufficient to improve sepsis outcomes. Alert fatigue due to the low PPV is likely the primary contributor to these results. A more sophisticated algorithm for sepsis identification is needed to improve outcomes.

  2. Generator replacement is associated with an increased rate of ICD lead alerts.

    PubMed

    Lovelock, Joshua D; Cruz, Cesar; Hoskins, Michael H; Jones, Paul; El-Chami, Mikhael F; Lloyd, Michael S; Leon, Angel; DeLurgio, David B; Langberg, Jonathan J

    2014-10-01

    Lead malfunction is an important cause of morbidity and mortality in patients with an implantable cardioverter-defibrillator (ICD). We have shown that the failure of recalled high-voltage leads significantly increases after ICD generator replacement. However, generator replacement has not been recognized as a predictor of lead failure in general. The purpose of this study is to assess the effect of ICD generator exchange on the rate of ICD lead alerts. A time-dependent Cox proportional hazards model was used to analyze a database of remotely monitored ICDs. The model assessed the impact of generator exchange on the rate of lead alerts after ICD generator replacement. The analysis included 60,219 patients followed for 37 ± 19 months. The 5-year lead survival was 99.3% (95% confidence interval 99.2%-99.4%). Of 60,219 patients, 7458 patients (12.9%) underwent ICD generator exchange without lead replacement. After generator replacement, the rate of lead alerts was more than 5-fold higher than in controls with leads of the same age without generator replacement (hazard ratio 5.19; 95% confidence interval 3.45-7.84). A large number of lead alerted within 3 months of generator replacement. Lead alerts were more common in patients with single- vs dual-chamber ICDs and in younger patients. Sex was not associated with lead alerts. Routine generator replacement is associated with a 5-fold higher risk of lead alert compared to age-matched leads without generator replacement. This suggests the need for intense surveillance after generator replacement and the development of techniques to minimize the risk of lead damage during generator replacement. Copyright © 2014 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  3. Use of a Clinical Decision Support System Alert to Prevent Supratherapeutic Vancomycin Concentrations

    PubMed Central

    Ralph, Rachel; Patel, Jean A.; Postelnick, Michael; Ziauddin, Salma; Flis, Weronika; Galal, Audrey N.

    2014-01-01

    Background: Alerts issued by clinical decision support systems (CDSS) may be useful to identify and prevent the occurrence of acute kidney injury among patients on nephrotoxic drugs, particularly vancomycin. Objective: The purpose of this instructive study was to determine the effectiveness of using a pharmacist-run CDSS alert of early serum creatinine increases in patients receiving intravenous vancomycin to decrease the proportion of severely elevated vancomycin concentrations. Methods: This was a retrospective study of a prospectively reviewed CDSS alert that triggered in patients with an increase in serum creatinine by 25% from baseline within 24 hours. Severely elevated vancomycin concentrations were divided into a control group (before alert implementation) and a study group (after alert implementation) and considered for study inclusion. The proportion of severely elevated vancomycin concentrations (ie, >30 mg/L) were collected in the control and study groups. Results: There were 1290 and 1501 vancomycin concentrations in the control group and the study group, respectively. A total of 696 CDSS alerts triggered during the study period. The proportion of severely elevated vancomycin troughs decreased from 5.3% (n = 68, median = 36.6 mg/L, interquartile range = 33.75-43.2 mg/L) in the control group to 3.7% (n = 55, median = 34.7 mg/L, interquartile range = 31.3-39.3 mg/L) in the study group. This reflects a statistically significant decrease in the proportion of severely elevated vancomycin concentrations (P = .04). Conclusion: Overall, this instructive analysis on a novel use of CDSS software suggests that the implementation of an alert based on early detection of serum creatinine changes led to a significant decrease in the proportion of severely elevated serum vancomycin concentrations.

  4. Look Closer: The Alertness of People with Profound Intellectual and Multiple Disabilities during Multi-Sensory Storytelling, a Time Sequential Analysis

    ERIC Educational Resources Information Center

    Ten Brug, Annet; Munde, Vera S.; van der Putten, Annette A.J.; Vlaskamp, Carla

    2015-01-01

    Introduction: Multi-sensory storytelling (MSST) is a storytelling method designed for individuals with profound intellectual and multiple disabilities (PIMD). It is essential that listeners be alert during MSST, so that they become familiar with their personalised stories. Repetition and the presentation of stimuli are likely to affect the…

  5. Smartphones for distributed multimode sensing: biological and environmental sensing and analysis

    NASA Astrophysics Data System (ADS)

    Feitshans, Tyler; Williams, Robert

    2013-05-01

    Active and Agile Environmental and Biological sensing are becoming obligatory to generate prompt warnings for the troops and law enforcements conducting missions in hostile environments. The traditional static sensing mesh networks which provide a coarse-grained (far-field) measurement of the environmental conditions like air quality, radiation , CO2, etc … would not serve the dynamic and localized changes in the environment, which requires a fine-grained (near-field) sensing solutions. Further, sensing the biological conditions of (healthy and injured) personnel in a contaminated environment and providing a personalized analysis of the life-threatening conditions in real-time would greatly aid the success of the mission. In this vein, under SATE and YATE programs, the research team at AFRL Tec^Edge Discovery labs had demonstrated the feasibility of developing Smartphone applications , that employ a suite of external environmental and biological sensors, which provide fine-grained and customized sensing in real-time fashion. In its current state, these smartphone applications leverage a custom designed modular standalone embedded platform (with external sensors) that can be integrated seamlessly with Smartphones for sensing and further provides connectivity to a back-end data architecture for archiving, analysis and dissemination of real-time alerts. Additionally, the developed smartphone applications have been successfully tested in the field with varied environmental sensors to sense humidity, CO2/CO, wind, etc…, ; and with varied biological sensors to sense body temperature and pulse with apt real-time analysis

  6. Extended workdays: Effects of 8-hour and 12-hour rotating shift schedules on test performance, subjective alertness, sleep patterns, and psychological variables

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosa, R.R.; Colligan, M.J.; Lewis, P.

    1986-06-01

    A newly instituted 3 to 4 day/12-hr rotating shift schedule was compared to the previous 5 to 7 day/8-hr schedule using standard laboratory-type measures of performance and alertness, and a questionnaire on sleep patterns and other personal habits. After seven months adaptation to the new schedule, a preliminary analysis indicates that there were some decrements in alertness, reductions in sleep, and disruptions of other personal activities during 12-hr workdays. Gastro-intestinal state improved during night shift, however, and increases in self-reported stress were reduced by the shortened workweek. These results are discussed in terms of trade-offs between longer workdays and shortermore » workweeks. It is emphasized that at this time no determination can be made of the extent of risk associated with these changes in alertness.« less

  7. IKOS: A Framework for Static Analysis based on Abstract Interpretation (Tool Paper)

    NASA Technical Reports Server (NTRS)

    Brat, Guillaume P.; Laserna, Jorge A.; Shi, Nija; Venet, Arnaud Jean

    2014-01-01

    The RTCA standard (DO-178C) for developing avionic software and getting certification credits includes an extension (DO-333) that describes how developers can use static analysis in certification. In this paper, we give an overview of the IKOS static analysis framework that helps developing static analyses that are both precise and scalable. IKOS harnesses the power of Abstract Interpretation and makes it accessible to a larger class of static analysis developers by separating concerns such as code parsing, model development, abstract domain management, results management, and analysis strategy. The benefits of the approach is demonstrated by a buffer overflow analysis applied to flight control systems.

  8. Optical flow and driver's kinematics analysis for state of alert sensing.

    PubMed

    Jiménez-Pinto, Javier; Torres-Torriti, Miguel

    2013-03-28

    Road accident statistics from different countries show that a significant number of accidents occur due to driver's fatigue and lack of awareness to traffic conditions. In particular, about 60% of the accidents in which long haul truck and bus drivers are involved are attributed to drowsiness and fatigue. It is thus fundamental to improve non-invasive systems for sensing a driver's state of alert. One of the main challenges to correctly resolve the state of alert is measuring the percentage of eyelid closure over time (PERCLOS), despite the driver's head and body movements. In this paper, we propose a technique that involves optical flow and driver's kinematics analysis to improve the robustness of the driver's alert state measurement under pose changes using a single camera with near-infrared illumination. The proposed approach infers and keeps track of the driver's pose in 3D space in order to ensure that eyes can be located correctly, even after periods of partial occlusion, for example, when the driver stares away from the camera. Our experiments show the effectiveness of the approach with a correct eyes detection rate of 99.41%, on average. The results obtained with the proposed approach in an experiment involving fifteen persons under different levels of sleep deprivation also confirm the discriminability of the fatigue levels. In addition to the measurement of fatigue and drowsiness, the pose tracking capability of the proposed approach has potential applications in distraction assessment and alerting of machine operators.

  9. Optical Flow and Driver's Kinematics Analysis for State of Alert Sensing

    PubMed Central

    Jiménez-Pinto, Javier; Torres-Torriti, Miguel

    2013-01-01

    Road accident statistics from different countries show that a significant number of accidents occur due to driver's fatigue and lack of awareness to traffic conditions. In particular, about 60% of the accidents in which long haul truck and bus drivers are involved are attributed to drowsiness and fatigue. It is thus fundamental to improve non-invasive systems for sensing a driver's state of alert. One of the main challenges to correctly resolve the state of alert is measuring the percentage of eyelid closure over time (PERCLOS), despite the driver's head and body movements. In this paper, we propose a technique that involves optical flow and driver's kinematics analysis to improve the robustness of the driver's alert state measurement under pose changes using a single camera with near-infrared illumination. The proposed approach infers and keeps track of the driver's pose in 3D space in order to ensure that eyes can be located correctly, even after periods of partial occlusion, for example, when the driver stares away from the camera. Our experiments show the effectiveness of the approach with a correct eyes detection rate of 99.41%, on average. The results obtained with the proposed approach in an experiment involving fifteen persons under different levels of sleep deprivation also confirm the discriminability of the fatigue levels. In addition to the measurement of fatigue and drowsiness, the pose tracking capability of the proposed approach has potential applications in distraction assessment and alerting of machine operators. PMID:23539029

  10. Impact of the sitagliptin alert on prescription of oral antihyperglycemic drugs in Japan.

    PubMed

    Sato, Daisaku; Sato, Yasunori; Masuda, Sachiko; Kimura, Hiromichi

    2012-12-01

    Sitagliptin, the first of a new class of dipeptidyl peptidase-4 (DPP-4)-inhibitory oral antihyperglycemic drugs (OHDs), was introduced in Japan in December 2009. In April 2010 a safety alert was issued regarding the risk of serious hypoglycemic events when the drug is used in combination with high-dose sulfonylureas (SUs). To investigate trends in prescription of OHDs before and after the launch of sitagliptin, and before and after the safety alert, in order to evaluate changes in the prescribing behavior of various groups of physicians in response to the safety alert. Japan. Prescription data from 6,500 institutions, randomly collected from 300 Japanese pharmacies were used. A cohort of 87,678 patients with 813,374 prescriptions for OHDs, among which 464,079 included SUs (glimepiride: 317,423), was collected from August 2009 to 31 December 2010. Logistic regression analysis was conducted. Prescription trends for sitagliptin and SUs, stratified by age, gender, types of prescribers and institutions. The safety alert recommending a reduction of SU dosing was well reflected in prescriptions issued after the alert (glimepiride dose reduction from 2.78 ± 1.86 mg to 2.32 ± 1.68), especially in prescriptions issued by diabetes specialists (from 2.27 ± 1.81 mg to 1.87 ± 1.47 mg). The dose of background SUs in patients who started sitagliptin early was higher (before alert: 2.70 ± 1.80 mg, after alert: 2.51 ± 1.74 mg) than in patients without experience of sitagliptin (2.12 ± 1.57 mg). This may indicate that patients receiving high-dose SUs were selected for sitagliptin, and this might be a factor in the high frequency of hypoglycemia in the early launch phase of sitagliptin. The sitagliptin safety alert had a clear impact on prescribing behavior, but the impact appeared to depend on prescribers' backgrounds. Our findings should be helpful for developing a safer drug launching strategy for new classes of drugs in established categories.

  11. Monitoring alert and drowsy states by modeling EEG source nonstationarity

    NASA Astrophysics Data System (ADS)

    Hsu, Sheng-Hsiou; Jung, Tzyy-Ping

    2017-10-01

    Objective. As a human brain performs various cognitive functions within ever-changing environments, states of the brain characterized by recorded brain activities such as electroencephalogram (EEG) are inevitably nonstationary. The challenges of analyzing the nonstationary EEG signals include finding neurocognitive sources that underlie different brain states and using EEG data to quantitatively assess the state changes. Approach. This study hypothesizes that brain activities under different states, e.g. levels of alertness, can be modeled as distinct compositions of statistically independent sources using independent component analysis (ICA). This study presents a framework to quantitatively assess the EEG source nonstationarity and estimate levels of alertness. The framework was tested against EEG data collected from 10 subjects performing a sustained-attention task in a driving simulator. Main results. Empirical results illustrate that EEG signals under alert versus drowsy states, indexed by reaction speeds to driving challenges, can be characterized by distinct ICA models. By quantifying the goodness-of-fit of each ICA model to the EEG data using the model deviation index (MDI), we found that MDIs were significantly correlated with the reaction speeds (r  =  -0.390 with alertness models and r  =  0.449 with drowsiness models) and the opposite correlations indicated that the two models accounted for sources in the alert and drowsy states, respectively. Based on the observed source nonstationarity, this study also proposes an online framework using a subject-specific ICA model trained with an initial (alert) state to track the level of alertness. For classification of alert against drowsy states, the proposed online framework achieved an averaged area-under-curve of 0.745 and compared favorably with a classic power-based approach. Significance. This ICA-based framework provides a new way to study changes of brain states and can be applied to monitoring cognitive or mental states of human operators in attention-critical settings or in passive brain-computer interfaces.

  12. Central Fetal Monitoring With and Without Computer Analysis: A Randomized Controlled Trial.

    PubMed

    Nunes, Inês; Ayres-de-Campos, Diogo; Ugwumadu, Austin; Amin, Pina; Banfield, Philip; Nicoll, Antony; Cunningham, Simon; Sousa, Paulo; Costa-Santos, Cristina; Bernardes, João

    2017-01-01

    To evaluate whether intrapartum fetal monitoring with computer analysis and real-time alerts decreases the rate of newborn metabolic acidosis or obstetric intervention when compared with visual analysis. A randomized clinical trial carried out in five hospitals in the United Kingdom evaluated women with singleton, vertex fetuses of 36 weeks of gestation or greater during labor. Continuous central fetal monitoring by computer analysis and online alerts (experimental arm) was compared with visual analysis (control arm). Fetal blood sampling and electrocardiographic ST waveform analysis were available in both arms. The primary outcome was incidence of newborn metabolic acidosis (pH less than 7.05 and base deficit greater than 12 mmol/L). Prespecified secondary outcomes included operative delivery, use of fetal blood sampling, low 5-minute Apgar score, neonatal intensive care unit admission, hypoxic-ischemic encephalopathy, and perinatal death. A sample size of 3,660 per group (N=7,320) was planned to be able to detect a reduction in the rate of metabolic acidosis from 2.8% to 1.8% (two-tailed α of 0.05 with 80% power). From August 2011 through July 2014, 32,306 women were assessed for eligibility and 7,730 were randomized: 3,961 to computer analysis and online alerts, and 3,769 to visual analysis. Baseline characteristics were similar in both groups. Metabolic acidosis occurred in 16 participants (0.40%) in the experimental arm and 22 participants (0.58%) in the control arm (relative risk 0.69 [0.36-1.31]). No statistically significant differences were found in the incidence of secondary outcomes. Compared with visual analysis, computer analysis of fetal monitoring signals with real-time alerts did not significantly reduce the rate of metabolic acidosis or obstetric intervention. A lower-than-expected rate of newborn metabolic acidosis was observed in both arms of the trial. ISRCTN Registry, http://www.isrctn.com, ISRCTN42314164.

  13. Neurofeedback training aimed to improve focused attention and alertness in children with ADHD: a study of relative power of EEG rhythms using custom-made software application.

    PubMed

    Hillard, Brent; El-Baz, Ayman S; Sears, Lonnie; Tasman, Allan; Sokhadze, Estate M

    2013-07-01

    Neurofeedback is a nonpharmacological treatment for attention-deficit hyperactivity disorder (ADHD). We propose that operant conditioning of electroencephalogram (EEG) in neurofeedback training aimed to mitigate inattention and low arousal in ADHD, will be accompanied by changes in EEG bands' relative power. Patients were 18 children diagnosed with ADHD. The neurofeedback protocol ("Focus/Alertness" by Peak Achievement Trainer) has a focused attention and alertness training mode. The neurofeedback protocol provides one for Focus and one for Alertness. This does not allow for collecting information regarding changes in specific EEG bands (delta, theta, alpha, low and high beta, and gamma) power within the 2 to 45 Hz range. Quantitative EEG analysis was completed on each of twelve 25-minute-long sessions using a custom-made MatLab application to determine the relative power of each of the aforementioned EEG bands throughout each session, and from the first session to the last session. Additional statistical analysis determined significant changes in relative power within sessions (from minute 1 to minute 25) and between sessions (from session 1 to session 12). Analysis was of relative power of theta, alpha, low and high beta, theta/alpha, theta/beta, and theta/low beta and theta/high beta ratios. Additional secondary measures of patients' post-neurofeedback outcomes were assessed, using an audiovisual selective attention test (IVA + Plus) and behavioral evaluation scores from the Aberrant Behavior Checklist. Analysis of data computed in the MatLab application, determined that theta/low beta and theta/alpha ratios decreased significantly from session 1 to session 12, and from minute 1 to minute 25 within sessions. The findings regarding EEG changes resulting from brain wave self-regulation training, along with behavioral evaluations, will help elucidate neural mechanisms of neurofeedback aimed to improve focused attention and alertness in ADHD.

  14. Alert dwell time: introduction of a measure to evaluate interruptive clinical decision support alerts

    PubMed Central

    McDaniel, Robert B; Burlison, Jonathan D; Baker, Donald K; Hasan, Murad; Robertson, Jennifer; Hartford, Christine; Howard, Scott C; Sablauer, Andras

    2016-01-01

    Metrics for evaluating interruptive prescribing alerts have many limitations. Additional methods are needed to identify opportunities to improve alerting systems and prevent alert fatigue. In this study, the authors determined whether alert dwell time—the time elapsed from when an interruptive alert is generated to when it is dismissed—could be calculated by using historical alert data from log files. Drug–drug interaction (DDI) alerts from 3 years of electronic health record data were queried. Alert dwell time was calculated for 25,965 alerts, including 777 unique DDIs. The median alert dwell time was 8 s (range, 1–4913 s). Resident physicians had longer median alert dwell times than other prescribers (P < .001). The 10 most frequent DDI alerts (n = 8759 alerts) had shorter median dwell times than alerts that only occurred once (P < .001). This metric can be used in future research to evaluate the effectiveness and efficiency of interruptive prescribing alerts. PMID:26499101

  15. Reduced Effectiveness of Interruptive Drug-Drug Interaction Alerts after Conversion to a Commercial Electronic Health Record.

    PubMed

    Wright, Adam; Aaron, Skye; Seger, Diane L; Samal, Lipika; Schiff, Gordon D; Bates, David W

    2018-05-15

    Drug-drug interaction (DDI) alerts in electronic health records (EHRs) can help prevent adverse drug events, but such alerts are frequently overridden, raising concerns about their clinical usefulness and contribution to alert fatigue. To study the effect of conversion to a commercial EHR on DDI alert and acceptance rates. Two before-and-after studies. 3277 clinicians who received a DDI alert in the outpatient setting. Introduction of a new, commercial EHR and subsequent adjustment of DDI alerting criteria. Alert burden and proportion of alerts accepted. Overall interruptive DDI alert burden increased by a factor of 6 from the legacy EHR to the commercial EHR. The acceptance rate for the most severe alerts fell from 100 to 8.4%, and from 29.3 to 7.5% for medium severity alerts (P < 0.001). After disabling the least severe alerts, total DDI alert burden fell by 50.5%, and acceptance of Tier 1 alerts rose from 9.1 to 12.7% (P < 0.01). Changing from a highly tailored DDI alerting system to a more general one as part of an EHR conversion decreased acceptance of DDI alerts and increased alert burden on users. The decrease in acceptance rates cannot be fully explained by differences in the clinical knowledge base, nor can it be fully explained by alert fatigue associated with increased alert burden. Instead, workflow factors probably predominate, including timing of alerts in the prescribing process, lack of differentiation of more and less severe alerts, and features of how users interact with alerts.

  16. INITIATE: An Intelligent Adaptive Alert Environment.

    PubMed

    Jafarpour, Borna; Abidi, Samina Raza; Ahmad, Ahmad Marwan; Abidi, Syed Sibte Raza

    2015-01-01

    Exposure to a large volume of alerts generated by medical Alert Generating Systems (AGS) such as drug-drug interaction softwares or clinical decision support systems over-whelms users and causes alert fatigue in them. Some of alert fatigue effects are ignoring crucial alerts and longer response times. A common approach to avoid alert fatigue is to devise mechanisms in AGS to stop them from generating alerts that are deemed irrelevant. In this paper, we present a novel framework called INITIATE: an INtellIgent adapTIve AlerT Environment to avoid alert fatigue by managing alerts generated by one or more AGS. We have identified and categories the lifecycle of different alerts and have developed alert management logic as per the alerts' lifecycle. Our framework incorporates an ontology that represents the alert management strategy and an alert management engine that executes this strategy. Our alert management framework offers the following features: (1) Adaptability based on users' feedback; (2) Personalization and aggregation of messages; and (3) Connection to Electronic Medical Records by implementing a HL7 Clinical Document Architecture parser.

  17. Feature-based alert correlation in security systems using self organizing maps

    NASA Astrophysics Data System (ADS)

    Kumar, Munesh; Siddique, Shoaib; Noor, Humera

    2009-04-01

    The security of the networks has been an important concern for any organization. This is especially important for the defense sector as to get unauthorized access to the sensitive information of an organization has been the prime desire for cyber criminals. Many network security techniques like Firewall, VPN Concentrator etc. are deployed at the perimeter of network to deal with attack(s) that occur(s) from exterior of network. But any vulnerability that causes to penetrate the network's perimeter of defense, can exploit the entire network. To deal with such vulnerabilities a system has been evolved with the purpose of generating an alert for any malicious activity triggered against the network and its resources, termed as Intrusion Detection System (IDS). The traditional IDS have still some deficiencies like generating large number of alerts, containing both true and false one etc. By automatically classifying (correlating) various alerts, the high-level analysis of the security status of network can be identified and the job of network security administrator becomes much easier. In this paper we propose to utilize Self Organizing Maps (SOM); an Artificial Neural Network for correlating large amount of logged intrusion alerts based on generic features such as Source/Destination IP Addresses, Port No, Signature ID etc. The different ways in which alerts can be correlated by Artificial Intelligence techniques are also discussed. . We've shown that the strategy described in the paper improves the efficiency of IDS by better correlating the alerts, leading to reduced false positives and increased competence of network administrator.

  18. Handler beliefs affect scent detection dog outcomes.

    PubMed

    Lit, Lisa; Schweitzer, Julie B; Oberbauer, Anita M

    2011-05-01

    Our aim was to evaluate how human beliefs affect working dog outcomes in an applied environment. We asked whether beliefs of scent detection dog handlers affect team performance and evaluated relative importance of human versus dog influences on handlers' beliefs. Eighteen drug and/or explosive detection dog/handler teams each completed two sets of four brief search scenarios (conditions). Handlers were falsely told that two conditions contained a paper marking scent location (human influence). Two conditions contained decoy scents (food/toy) to encourage dog interest in a false location (dog influence). Conditions were (1) control; (2) paper marker; (3) decoy scent; and (4) paper marker at decoy scent. No conditions contained drug or explosive scent; any alerting response was incorrect. A repeated measures analysis of variance was used with search condition as the independent variable and number of alerts as the dependent variable. Additional nonparametric tests compared human and dog influence. There were 225 incorrect responses, with no differences in mean responses across conditions. Response patterns differed by condition. There were more correct (no alert responses) searches in conditions without markers. Within marked conditions, handlers reported that dogs alerted more at marked locations than other locations. Handlers' beliefs that scent was present potentiated handler identification of detection dog alerts. Human more than dog influences affected alert locations. This confirms that handler beliefs affect outcomes of scent detection dog deployments.

  19. [Unusual behaviors in sleep as "compensatory" reactions, aimed at normalizing sleep-alertness cycles].

    PubMed

    Gol'bin, A Ts; Guzeva, V I; Shepoval'nikov, A N

    2013-01-01

    The present article is an attempt to perform a conceptual clinical and physiological analysis of a large spec- trum of sleep-related phenomena called parasomnias in children, based on data from three independent in- stitutions. Parasonmias appear in the process of falling asleep, at the time of sleep stage changes, and upon awakening. They are common for both healthy children and those with neurological and psychiatric disorders. Brief descriptions of clinical pictures of several groups of parasomnias and their polysomnographic characteristics are presented. Instances of stereotyped rhythmic movements (e.g. head rocking), paroxysmal somatic and behavioral episodes (night terrors and nightmares), "static" phenomena (sleep with open eyes, strange body positions), as well as somnambulism are specifically described. Common features of parasomnias as a group have been identified (the "Parasomnia syndrome"). It was found that sleep architecture frequently normalizes after a parasomnia episode, whereas parasomnias are self-liquidated after sleep matures (self-cure). The significance of gender differences in parasomnias have been reviewed. Possible compensatory physiological functions of parasomnias acting as "switches" or "stabilizers" of sleep stages to "off-set" deviated or immature sleep-wake mechanisms were discussed.

  20. Brain-computer interface for alertness estimation and improving

    NASA Astrophysics Data System (ADS)

    Hramov, Alexander; Maksimenko, Vladimir; Hramova, Marina

    2018-02-01

    Using wavelet analysis of the signals of electrical brain activity (EEG), we study the processes of neural activity, associated with perception of visual stimuli. We demonstrate that the brain can process visual stimuli in two scenarios: (i) perception is characterized by destruction of the alpha-waves and increase in the high-frequency (beta) activity, (ii) the beta-rhythm is not well pronounced, while the alpha-wave energy remains unchanged. The special experiments show that the motivation factor initiates the first scenario, explained by the increasing alertness. Based on the obtained results we build the brain-computer interface and demonstrate how the degree of the alertness can be estimated and controlled in real experiment.

  1. Outcomes of an intervention to improve hospital antibiotic prescribing: interrupted time series with segmented regression analysis.

    PubMed

    Ansari, Faranak; Gray, Kirsteen; Nathwani, Dilip; Phillips, Gabby; Ogston, Simon; Ramsay, Craig; Davey, Peter

    2003-11-01

    To evaluate an intervention to reduce inappropriate use of key antibiotics with interrupted time series analysis. The intervention is a policy for appropriate use of Alert Antibiotics (carbapenems, glycopeptides, amphotericin, ciprofloxacin, linezolid, piperacillin-tazobactam and third-generation cephalosporins) implemented through concurrent, patient-specific feedback by clinical pharmacists. Statistical significance and effect size were calculated by segmented regression analysis of interrupted time series of drug use and cost for 2 years before and after the intervention started. Use of Alert Antibiotics increased before the intervention started but decreased steadily for 2 years thereafter. The changes in slope of the time series were 0.27 defined daily doses/100 bed-days per month (95% CI 0.19-0.34) and pound 1908 per month (95% CI pound 1238- pound 2578). The cost of development, dissemination and implementation of the intervention ( pound 20133) was well below the most conservative estimate of the reduction in cost ( pound 133296), which is the lower 95% CI of effect size assuming that cost would not have continued to increase without the intervention. However, if use had continued to increase, the difference between predicted and actual cost of Alert Antibiotics was pound 572448 (95% CI pound 435696- pound 709176) over the 24 months after the intervention started. Segmented regression analysis of pharmacy stock data is a simple, practical and robust method for measuring the impact of interventions to change prescribing. The Alert Antibiotic Monitoring intervention was associated with significant decreases in total use and cost in the 2 years after the programme was implemented. In our hospital, the value of the data far exceeded the cost of processing and analysis.

  2. Alert dwell time: introduction of a measure to evaluate interruptive clinical decision support alerts.

    PubMed

    McDaniel, Robert B; Burlison, Jonathan D; Baker, Donald K; Hasan, Murad; Robertson, Jennifer; Hartford, Christine; Howard, Scott C; Sablauer, Andras; Hoffman, James M

    2016-04-01

    Metrics for evaluating interruptive prescribing alerts have many limitations. Additional methods are needed to identify opportunities to improve alerting systems and prevent alert fatigue. In this study, the authors determined whether alert dwell time-the time elapsed from when an interruptive alert is generated to when it is dismissed-could be calculated by using historical alert data from log files. Drug-drug interaction (DDI) alerts from 3 years of electronic health record data were queried. Alert dwell time was calculated for 25,965 alerts, including 777 unique DDIs. The median alert dwell time was 8 s (range, 1-4913 s). Resident physicians had longer median alert dwell times than other prescribers (P < 001). The 10 most frequent DDI alerts (n = 8759 alerts) had shorter median dwell times than alerts that only occurred once (P < 001). This metric can be used in future research to evaluate the effectiveness and efficiency of interruptive prescribing alerts. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. Streaming Visual Analytics Workshop Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cook, Kristin A.; Burtner, Edwin R.; Kritzstein, Brian P.

    How can we best enable users to understand complex emerging events and make appropriate assessments from streaming data? This was the central question addressed at a three-day workshop on streaming visual analytics. This workshop was organized by Pacific Northwest National Laboratory for a government sponsor. It brought together forty researchers and subject matter experts from government, industry, and academia. This report summarizes the outcomes from that workshop. It describes elements of the vision for a streaming visual analytic environment and set of important research directions needed to achieve this vision. Streaming data analysis is in many ways the analysis andmore » understanding of change. However, current visual analytics systems usually focus on static data collections, meaning that dynamically changing conditions are not appropriately addressed. The envisioned mixed-initiative streaming visual analytics environment creates a collaboration between the analyst and the system to support the analysis process. It raises the level of discourse from low-level data records to higher-level concepts. The system supports the analyst’s rapid orientation and reorientation as situations change. It provides an environment to support the analyst’s critical thinking. It infers tasks and interests based on the analyst’s interactions. The system works as both an assistant and a devil’s advocate, finding relevant data and alerts as well as considering alternative hypotheses. Finally, the system supports sharing of findings with others. Making such an environment a reality requires research in several areas. The workshop discussions focused on four broad areas: support for critical thinking, visual representation of change, mixed-initiative analysis, and the use of narratives for analysis and communication.« less

  4. Combining Static Analysis and Model Checking for Software Analysis

    NASA Technical Reports Server (NTRS)

    Brat, Guillaume; Visser, Willem; Clancy, Daniel (Technical Monitor)

    2003-01-01

    We present an iterative technique in which model checking and static analysis are combined to verify large software systems. The role of the static analysis is to compute partial order information which the model checker uses to reduce the state space. During exploration, the model checker also computes aliasing information that it gives to the static analyzer which can then refine its analysis. The result of this refined analysis is then fed back to the model checker which updates its partial order reduction. At each step of this iterative process, the static analysis computes optimistic information which results in an unsafe reduction of the state space. However we show that the process converges to a fired point at which time the partial order information is safe and the whole state space is explored.

  5. Is there a link between the hospital-acquired injurious fall rates in US acute care hospitals and these institutions' implementation levels of computerized systems?

    PubMed

    Tzeng, Huey-Ming; Hu, Hsou Mei; Yin, Chang-Yi

    2011-12-01

    Medicare no longer reimburses acute care hospitals for the costs of additional care required due to hospital-acquired injuries. Consequently, this study explored the effective computerized systems to inform practice for better interventions to reduce fall risk. It provided a correlation between type of computerized system and hospital-acquired injurious fall rates at acute care hospitals in California, Florida, and New York. It used multiple publicly available data sets, with the hospital as the unit of analysis. Descriptive and Pearson correlation analyses were used. The analysis included 462 hospitals. Significant correlations could be categorized into two groups: (1) meaningful computerized systems that were associated with lower injurious fall rates: the decision support systems for drug allergy alerts, drug-drug interaction alerts, and drug-laboratory interaction alerts; and (2) computerized systems that were associated with higher injurious fall rates: the decision support system for drug-drug interaction alerts and the computerized provider order entry system for radiology tests. Future research may include additional states, multiple years of data, and patient-level data to validate this study's findings. This effort may further inform policy makers and the public about effective clinical computerized systems provided to clinicians to improve their practice decisions and care outcomes.

  6. Visual field progression in glaucoma: what is the specificity of the Guided Progression Analysis?

    PubMed

    Artes, Paul H; O'Leary, Neil; Nicolela, Marcelo T; Chauhan, Balwantray C; Crabb, David P

    2014-10-01

    To estimate the specificity of the Guided Progression Analysis (GPA) (Carl Zeiss Meditec, Dublin, CA) in individual patients with glaucoma. Observational cohort study. Thirty patients with open-angle glaucoma. In 30 patients with open-angle glaucoma, 1 eye (median mean deviation [MD], -2.5 decibels [dB]; interquartile range, -4.4 to -1.3 dB) was tested 12 times over 3 months (Humphrey Field Analyzer, Carl Zeiss Meditec; SITA Standard, 24-2). "Possible progression" and "likely progression" were determined with the GPA. These analyses were repeated after the order of the tests had been randomly rearranged (1000 unique permutations). Rate of false-positive alerts of "possible progression" and "likely progression" with the GPA. On average, the specificity of the GPA "likely progression" alert was high-for the entire sample, the mean rate of false-positive alerts after 10 follow-up tests was 2.6%. With "possible progression," the specificity was considerably lower (false-positive rate, 18.5%). Most important, the cumulative rate of false-positive alerts varied substantially among patients, from <1% to 80% with "possible progression" and from <0.1% to 20% with "likely progression." Factors associated with false-positive alerts were visual field variability (standard deviation of MD, Spearman's rho = 0.41, P<0.001) and the reliability indices (proportion of false-positive and false-negative responses, fixation losses, rho>0.31, P≤0.10). On average, progression criteria currently used in the GPA have high specificity, but some patients are more likely to show false-positive alerts than others. This is a natural consequence of population-based change criteria and may not matter in clinical trials and studies in which large groups of patients are compared. However, it must be considered when the GPA is used in clinical practice where specificity needs to be controlled for individual patients. Copyright © 2014 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  7. Automating slope monitoring in mines with terrestrial lidar scanners

    NASA Astrophysics Data System (ADS)

    Conforti, Dario

    2014-05-01

    Static terrestrial laser scanners (TLS) have been an important component of slope monitoring for some time, and many solutions for monitoring the progress of a slide have been devised over the years. However, all of these solutions have required users to operate the lidar equipment in the field, creating a high cost in time and resources, especially if the surveys must be performed very frequently. This paper presents a new solution for monitoring slides, developed using a TLS and an automated data acquisition, processing and analysis system. In this solution, a TLS is permanently mounted within sight of the target surface and connected to a control computer. The control software on the computer automatically triggers surveys according to a user-defined schedule, parses data into point clouds, and compares data against a baseline. The software can base the comparison against either the original survey of the site or the most recent survey, depending on whether the operator needs to measure the total or recent movement of the slide. If the displacement exceeds a user-defined safety threshold, the control computer transmits alerts via SMS text messaging and/or email, including graphs and tables describing the nature and size of the displacement. The solution can also be configured to trigger the external visual/audio alarm systems. If the survey areas contain high-traffic areas such as roads, the operator can mark them for exclusion in the comparison to prevent false alarms. To improve usability and safety, the control computer can connect to a local intranet and allow remote access through the software's web portal. This enables operators to perform most tasks with the TLS from their office, including reviewing displacement reports, downloading survey data, and adjusting the scan schedule. This solution has proved invaluable in automatically detecting and alerting users to potential danger within the monitored areas while lowering the cost and work required for monitoring. An explanation of the entire system and a post-acquisition data demonstration will be presented.

  8. Electromechanical actuators affected by multiple failures: Prognostic method based on spectral analysis techniques

    NASA Astrophysics Data System (ADS)

    Belmonte, D.; Vedova, M. D. L. Dalla; Ferro, C.; Maggiore, P.

    2017-06-01

    The proposal of prognostic algorithms able to identify precursors of incipient failures of primary flight command electromechanical actuators (EMA) is beneficial for the anticipation of the incoming failure: an early and correct interpretation of the failure degradation pattern, in fact, can trig an early alert of the maintenance crew, who can properly schedule the servomechanism replacement. An innovative prognostic model-based approach, able to recognize the EMA progressive degradations before his anomalous behaviors become critical, is proposed: the Fault Detection and Identification (FDI) of the considered incipient failures is performed analyzing proper system operational parameters, able to put in evidence the corresponding degradation path, by means of a numerical algorithm based on spectral analysis techniques. Subsequently, these operational parameters will be correlated with the actual EMA health condition by means of failure maps created by a reference monitoring model-based algorithm. In this work, the proposed method has been tested in case of EMA affected by combined progressive failures: in particular, partial stator single phase turn to turn short-circuit and rotor static eccentricity are considered. In order to evaluate the prognostic method, a numerical test-bench has been conceived. Results show that the method exhibit adequate robustness and a high degree of confidence in the ability to early identify an eventual malfunctioning, minimizing the risk of fake alarms or unannounced failures.

  9. Provider risk factors for medication administration error alerts: analyses of a large-scale closed-loop medication administration system using RFID and barcode.

    PubMed

    Hwang, Yeonsoo; Yoon, Dukyong; Ahn, Eun Kyoung; Hwang, Hee; Park, Rae Woong

    2016-12-01

    To determine the risk factors and rate of medication administration error (MAE) alerts by analyzing large-scale medication administration data and related error logs automatically recorded in a closed-loop medication administration system using radio-frequency identification and barcodes. The subject hospital adopted a closed-loop medication administration system. All medication administrations in the general wards were automatically recorded in real-time using radio-frequency identification, barcodes, and hand-held point-of-care devices. MAE alert logs recorded during a full 1 year of 2012. We evaluated risk factors for MAE alerts including administration time, order type, medication route, the number of medication doses administered, and factors associated with nurse practices by logistic regression analysis. A total of 2 874 539 medication dose records from 30 232 patients (882.6 patient-years) were included in 2012. We identified 35 082 MAE alerts (1.22% of total medication doses). The MAE alerts were significantly related to administration at non-standard time [odds ratio (OR) 1.559, 95% confidence interval (CI) 1.515-1.604], emergency order (OR 1.527, 95%CI 1.464-1.594), and the number of medication doses administered (OR 0.993, 95%CI 0.992-0.993). Medication route, nurse's employment duration, and working schedule were also significantly related. The MAE alert rate was 1.22% over the 1-year observation period in the hospital examined in this study. The MAE alerts were significantly related to administration time, order type, medication route, the number of medication doses administered, nurse's employment duration, and working schedule. The real-time closed-loop medication administration system contributed to improving patient safety by preventing potential MAEs. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  10. Web-based Tsunami Early Warning System: a case study of the 2010 Kepulaunan Mentawai Earthquake and Tsunami

    NASA Astrophysics Data System (ADS)

    Ulutas, E.; Inan, A.; Annunziato, A.

    2012-06-01

    This study analyzes the response of the Global Disasters Alerts and Coordination System (GDACS) in relation to a case study: the Kepulaunan Mentawai earthquake and related tsunami, which occurred on 25 October 2010. The GDACS, developed by the European Commission Joint Research Center, combines existing web-based disaster information management systems with the aim to alert the international community in case of major disasters. The tsunami simulation system is an integral part of the GDACS. In more detail, the study aims to assess the tsunami hazard on the Mentawai and Sumatra coasts: the tsunami heights and arrival times have been estimated employing three propagation models based on the long wave theory. The analysis was performed in three stages: (1) pre-calculated simulations by using the tsunami scenario database for that region, used by the GDACS system to estimate the alert level; (2) near-real-time simulated tsunami forecasts, automatically performed by the GDACS system whenever a new earthquake is detected by the seismological data providers; and (3) post-event tsunami calculations using GCMT (Global Centroid Moment Tensor) fault mechanism solutions proposed by US Geological Survey (USGS) for this event. The GDACS system estimates the alert level based on the first type of calculations and on that basis sends alert messages to its users; the second type of calculations is available within 30-40 min after the notification of the event but does not change the estimated alert level. The third type of calculations is performed to improve the initial estimations and to have a better understanding of the extent of the possible damage. The automatic alert level for the earthquake was given between Green and Orange Alert, which, in the logic of GDACS, means no need or moderate need of international humanitarian assistance; however, the earthquake generated 3 to 9 m tsunami run-up along southwestern coasts of the Pagai Islands where 431 people died. The post-event calculations indicated medium-high humanitarian impacts.

  11. Advanced alerting features: displaying new relevant data and retracting alerts.

    PubMed Central

    Kuperman, G. J.; Hiltz, F. L.; Teich, J. M.

    1997-01-01

    We added two advanced features to our automated alerting system. The first feature identifies and displays, at the time an alert is reviewed, relevant data filed between the login time of a specimen leading to an alerting result and the time the alert is reviewed. Relevant data is defined as data of the same kind as generated the alert. The other feature retracts alerts when the alerting value is edited and no longer satisfies the alerting criteria. We evaluated the two features for a 14-week period (new relevant data) and a 6-week period (retraction). Of a total of 1104 alerts in the 14-week evaluation, 286 (25.9%) had new relevant data displayed at alert review time. Of the 286, 75.2% were due to additions of comments to the original piece of alerting data; 24.1% were due to new or pending laboratory results of the same type that generated the alert. Two alerts (out of 490) were retracted in a 6 week period. We conclude that in our system, new clinically relevant data is often added between the time of specimen login and the time that an alerting result from that specimen is reviewed. Retractions occur rarely but are important to detect and communicate. PMID:9357625

  12. Towards eradication of inappropriate therapies for ICD lead failure by combining comprehensive remote monitoring and lead noise alerts.

    PubMed

    Ploux, Sylvain; Swerdlow, Charles D; Strik, Marc; Welte, Nicolas; Klotz, Nicolas; Ritter, Philippe; Haïssaguerre, Michel; Bordachar, Pierre

    2018-06-02

    Recognition of implantable cardioverter defibrillator (ICD) lead malfunction before occurrence of life threatening complications is crucial. We aimed to assess the effectiveness of remote monitoring associated or not with a lead noise alert for early detection of ICD lead failure. From October 2013 to April 2017, a median of 1,224 (578-1,958) ICD patients were remotely monitored with comprehensive analysis of all transmitted materials. ICD lead failure and subsequent device interventions were prospectively collected in patients with (RMLN) and without (RM) a lead noise alert (Abbott Secure Sense™ or Medtronic Lead Integrity Alert™) in their remote monitoring system. During a follow-up of 4,457 patient years, 64 lead failures were diagnosed. Sixty-one (95%) of the diagnoses were made before any clinical complication occurred. Inappropriate shocks were delivered in only one patient of each group (3%), with an annual rate of 0.04%. All high voltage conductor failures were identified remotely by a dedicated impedance alert in 10 patients. Pace-sense component failures were correctly identified by a dedicated alert in 77% (17 of 22) of the RMLN group versus 25% (8 of 32) of the RM group (P = 0.002). The absence of a lead noise alert was associated with a 16-fold increase in the likelihood of initiating either a shock or ATP (OR: 16.0, 95% CI 1.8-143.3; P = 0.01). ICD remote monitoring with systematic review of all transmitted data is associated with a very low rate of inappropriate shocks related to lead failure. Dedicated noise alerts further reduce inappropriate detection of ventricular arrhythmias. © 2018 Wiley Periodicals, Inc.

  13. Investigating the contribution of short wavelengths in the alerting effect of bright light.

    PubMed

    Sasseville, Alexandre; Martin, Jeanne Sophie; Houle, Jérôme; Hébert, Marc

    2015-11-01

    Short-wavelengths can have an acute impact on alertness, which is allegedly due to their action on intrinsically photosensitive retinal ganglion cells. Classical photoreceptors cannot, however, be excluded at this point in time as contributors to the alerting effect of light. The objective of this study was to compare the alerting effect at night of a white LED light source while wearing blue-blockers or not, in order to establish the contribution of short-wavelengths. 20 participants stayed awake under dim light (< 5 lx) from 23:00 h to 04:00 h on two consecutive nights. On the second night, participants were randomly assigned to one light condition for 30 min starting at 3:00 h. Group A (5M/5F) was exposed to 500 μW/cm(2) of unfiltered LED light, while group B (4M/6F) was required to wear blue-blocking glasses, while exposed to 1500 μW/cm(2) from the same light device in order to achieve 500 μW/cm(2) at eye level (as measured behind the glasses). Subjective alertness, energy, mood and anxiety were assessed for both nights at 23:30 h, 01:30 h and 03:30 h using a visual analog scale (VAS). Subjective sleepiness was assessed with the Stanford Sleepiness Scale (SSS). Subjects also performed the Conners' Continuous Performance Test II (CPT-II) in order to assess objective alertness. Mixed model analysis was used to compare VAS, SSS and CPT-II parameters. No difference between group A and group B was observed for subjective alertness, energy, mood, anxiety and sleepiness, as well as CPT-II parameters. Subjective alertness (p < 0.001), energy (p < 0.001) and sleepiness (p < 0.05) were, however improved after light exposure on the second night independently of the light condition. The current study shows that when sleepiness is high, the alerting effect of light can still be triggered at night in the absence of short-wavelengths with a 30 minute light pulse of 500 μW/cm(2). This suggests that the underlying mechanism by which a brief polychromatic light exposure improves alertness is not solely due to short-wavelengths through intrinsically photosensitive retinal ganglion cells.

  14. Technologic Distractions (Part 1): Summary of Approaches to Manage Alert Quantity With Intent to Reduce Alert Fatigue and Suggestions for Alert Fatigue Metrics.

    PubMed

    Kane-Gill, Sandra L; O'Connor, Michael F; Rothschild, Jeffrey M; Selby, Nicholas M; McLean, Barbara; Bonafide, Christopher P; Cvach, Maria M; Hu, Xiao; Konkani, Avinash; Pelter, Michele M; Winters, Bradford D

    2017-09-01

    To provide ICU clinicians with evidence-based guidance on tested interventions that reduce or prevent alert fatigue within clinical decision support systems. Systematic review of PubMed, Embase, SCOPUS, and CINAHL for relevant literature from 1966 to February 2017. Focus on critically ill patients and included evaluations in other patient care settings, as well. Identified interventions designed to reduce or prevent alert fatigue within clinical decision support systems. Study selection was based on one primary key question to identify effective interventions that attempted to reduce alert fatigue and three secondary key questions that covered the negative effects of alert fatigue, potential unintended consequences of efforts to reduce alert fatigue, and ideal alert quantity. Data were abstracted by two reviewers independently using a standardized abstraction tool. Surveys, meeting abstracts, "gray" literature, studies not available in English, and studies with non-original data were excluded. For the primary key question, articles were excluded if they did not provide a comparator as key question 1 was designed as a problem, intervention, comparison, and outcome question. We anticipated that reduction in alert fatigue, including the concept of desensitization may not be directly measured and thus considered interventions that reduced alert quantity as a surrogate marker for alert fatigue. Twenty-six articles met the inclusion criteria. Approaches for managing alert fatigue in the ICU are provided as a result of reviewing tested interventions that reduced alert quantity with the anticipated effect of reducing fatigue. Suggested alert management strategies include prioritizing alerts, developing sophisticated alerts, customizing commercially available alerts, and including end user opinion in alert selection. Alert fatigue itself is studied less frequently, as an outcome, and there is a need for more precise evaluation. Standardized metrics for alert fatigue is needed to advance the field. Suggestions for standardized metrics are provided in this document.

  15. Post-crisis analysis of an ineffective tsunami alert: the 2010 earthquake in Maule, Chile.

    PubMed

    Soulé, Bastien

    2014-04-01

    Considering its huge magnitude and its location in a densely populated area of Chile, the Maule seism of 27 February 2010 generated a low amount of victims. However, post-seismic tsunamis were particularly devastating on that day; surprisingly, no full alert was launched, not at the national, regional or local level. This earthquake and associated tsunamis are of interest in the context of natural hazards management as well as crisis management planning. Instead of focusing exclusively on the event itself, this article places emphasis on the process, systems and long-term approach that led the tsunami alert mechanism to be ineffectual. Notably, this perspective reveals interrelated forerunner signs of vulnerability. © 2014 The Author(s). Disasters © Overseas Development Institute, 2014.

  16. Examining Lead Exposures in California through State-Issued Health Alerts for Food Contamination and an Exposure-Based Candy Testing Program.

    PubMed

    Handley, Margaret A; Nelson, Kali; Sanford, Eric; Clarity, Cassidy; Emmons-Bell, Sophia; Gorukanti, Anuhandra; Kennelly, Patrick

    2017-10-26

    In California, the annual number of children under age 6 y of age with blood lead levels (BLL) ≥10μg/dL is estimated at over 1,000 cases, and up to 10,000 cases when BLL between 4.5 and 9.5 μg/dL are included. State-issued health alerts for food contamination provide one strategy for tracking sources of food-related lead exposures. As well, California passed legislation in 2006 for the Food and Drug Branch (FDB) of the state health department to test and identify lead in candy. This report presents health alert data from California over a 14-y period, compares data before and after the candy testing program began, and examines country of origin, ZIP code data, and time from candy testing to release of health alerts for lead-contaminated candies for 2011-2012. After 2007, health alerts issued for lead in candy and food increased significantly. Analysis of candy-testing data indicated that multiple counties and ZIP codes were affected. Seventeen candies with high lead concentrations were identified, resulting in rapid dissemination (<2wk) of health alerts to local health departments and community clinicians and to the public. Surveillance of lead exposures from state-based food and candy testing programs provides an opportunity to identify and immediately act to remove nonpaint sources of lead affecting children. https://doi.org/10.1289/EHP2582.

  17. Alerting, orienting or executive attention networks: differential patters of pupil dilations

    PubMed Central

    Geva, Ronny; Zivan, Michal; Warsha, Aviv; Olchik, Dov

    2013-01-01

    Attention capacities, alerting responses, orienting to sensory stimulation, and executive monitoring of performance are considered independent yet interrelated systems. These operations play integral roles in regulating the behavior of diverse species along the evolutionary ladder. Each of the primary attention constructs—alerting, orienting, and executive monitoring—involves salient autonomic correlates as evidenced by changes in reactive pupil dilation (PD), heart rate, and skin conductance. Recent technological advances that use remote high-resolution recording may allow the discernment of temporo-spatial attributes of autonomic responses that characterize the alerting, orienting, and executive monitoring networks during free viewing, irrespective of voluntary performance. This may deepen the understanding of the roles of autonomic regulation in these mental operations and may deepen our understanding of behavioral changes in verbal as well as in non-verbal species. The aim of this study was to explore differences between psychosensory PD responses in alerting, orienting, and executive conflict monitoring tasks to generate estimates of concurrent locus coeruleus (LC) noradrenergic input trajectories in healthy human adults using the attention networks test (ANT). The analysis revealed a construct-specific pattern of pupil responses: alerting is characterized by an early component (Pa), its acceleration enables covert orienting, and executive control is evidenced by a prominent late component (Pe). PD characteristics seem to be task-sensitive, allowing exploration of mental operations irrespective of conscious voluntary responses. These data may facilitate development of studies designed to assess mental operations in diverse species using autonomic responses. PMID:24133422

  18. Disrupted Structural and Functional Networks and Their Correlation with Alertness in Right Temporal Lobe Epilepsy: A Graph Theory Study.

    PubMed

    Jiang, Wenyu; Li, Jianping; Chen, Xuemei; Ye, Wei; Zheng, Jinou

    2017-01-01

    Previous studies have shown that temporal lobe epilepsy (TLE) involves abnormal structural or functional connectivity in specific brain areas. However, limited comprehensive studies have been conducted on TLE associated changes in the topological organization of structural and functional networks. Additionally, epilepsy is associated with impairment in alertness, a fundamental component of attention. In this study, structural networks were constructed using diffusion tensor imaging tractography, and functional networks were obtained from resting-state functional MRI temporal series correlations in 20 right temporal lobe epilepsy (rTLE) patients and 19 healthy controls. Global network properties were computed by graph theoretical analysis, and correlations were assessed between global network properties and alertness. The results from these analyses showed that rTLE patients exhibit abnormal small-world attributes in structural and functional networks. Structural networks shifted toward more regular attributes, but functional networks trended toward more random attributes. After controlling for the influence of the disease duration, negative correlations were found between alertness, small-worldness, and the cluster coefficient. However, alertness did not correlate with either the characteristic path length or global efficiency in rTLE patients. Our findings show that disruptions of the topological construction of brain structural and functional networks as well as small-world property bias are associated with deficits in alertness in rTLE patients. These data suggest that reorganization of brain networks develops as a mechanism to compensate for altered structural and functional brain function during disease progression.

  19. Final Report: Computer-aided Human Centric Cyber Situation Awareness

    DTIC Science & Technology

    2016-03-20

    logs, OS audit trails, vulnerability reports, and packet dumps ), weeding out the false positives, grouping the related indicators so that different...short time duration of each visual stimulus in an fMRI study, we have designed “network security analysis cards ” that require the subject to...determine whether alerts in the cards indicate malicious events. Two types of visual displays of alerts (i.e., tabular display and node-link display) are

  20. Clinical Decision Support Alert Appropriateness: A Review and Proposal for Improvement

    PubMed Central

    McCoy, Allison B.; Thomas, Eric J.; Krousel-Wood, Marie; Sittig, Dean F.

    2014-01-01

    Background Many healthcare providers are adopting clinical decision support (CDS) systems to improve patient safety and meet meaningful use requirements. Computerized alerts that prompt clinicians about drug-allergy, drug-drug, and drug-disease warnings or provide dosing guidance are most commonly implemented. Alert overrides, which occur when clinicians do not follow the guidance presented by the alert, can hinder improved patient outcomes. Methods We present a review of CDS alerts and describe a proposal to develop novel methods for evaluating and improving CDS alerts that builds upon traditional informatics approaches. Our proposal incorporates previously described models for predicting alert overrides that utilize retrospective chart review to determine which alerts are clinically relevant and which overrides are justifiable. Results Despite increasing implementations of CDS alerts, detailed evaluations rarely occur because of the extensive labor involved in manual chart reviews to determine alert and response appropriateness. Further, most studies have solely evaluated alert overrides that are appropriate or justifiable. Our proposal expands the use of web-based monitoring tools with an interactive dashboard for evaluating CDS alert and response appropriateness that incorporates the predictive models. The dashboard provides 2 views, an alert detail view and a patient detail view, to provide a full history of alerts and help put the patient's events in context. Conclusion The proposed research introduces several innovations to address the challenges and gaps in alert evaluations. This research can transform alert evaluation processes across healthcare settings, leading to improved CDS, reduced alert fatigue, and increased patient safety. PMID:24940129

  1. A framework for evaluating the appropriateness of clinical decision support alerts and responses

    PubMed Central

    Waitman, Lemuel R; Lewis, Julia B; Wright, Julie A; Choma, David P; Miller, Randolph A; Peterson, Josh F

    2011-01-01

    Objective Alerting systems, a type of clinical decision support, are increasingly prevalent in healthcare, yet few studies have concurrently measured the appropriateness of alerts with provider responses to alerts. Recent reports of suboptimal alert system design and implementation highlight the need for better evaluation to inform future designs. The authors present a comprehensive framework for evaluating the clinical appropriateness of synchronous, interruptive medication safety alerts. Methods Through literature review and iterative testing, metrics were developed that describe successes, justifiable overrides, provider non-adherence, and unintended adverse consequences of clinical decision support alerts. The framework was validated by applying it to a medication alerting system for patients with acute kidney injury (AKI). Results Through expert review, the framework assesses each alert episode for appropriateness of the alert display and the necessity and urgency of a clinical response. Primary outcomes of the framework include the false positive alert rate, alert override rate, provider non-adherence rate, and rate of provider response appropriateness. Application of the framework to evaluate an existing AKI medication alerting system provided a more complete understanding of the process outcomes measured in the AKI medication alerting system. The authors confirmed that previous alerts and provider responses were most often appropriate. Conclusion The new evaluation model offers a potentially effective method for assessing the clinical appropriateness of synchronous interruptive medication alerts prior to evaluating patient outcomes in a comparative trial. More work can determine the generalizability of the framework for use in other settings and other alert types. PMID:21849334

  2. Medication-related clinical decision support alert overrides in inpatients.

    PubMed

    Nanji, Karen C; Seger, Diane L; Slight, Sarah P; Amato, Mary G; Beeler, Patrick E; Her, Qoua L; Dalleur, Olivia; Eguale, Tewodros; Wong, Adrian; Silvers, Elizabeth R; Swerdloff, Michael; Hussain, Salman T; Maniam, Nivethietha; Fiskio, Julie M; Dykes, Patricia C; Bates, David W

    2018-05-01

    To define the types and numbers of inpatient clinical decision support alerts, measure the frequency with which they are overridden, and describe providers' reasons for overriding them and the appropriateness of those reasons. We conducted a cross-sectional study of medication-related clinical decision support alerts over a 3-year period at a 793-bed tertiary-care teaching institution. We measured the rate of alert overrides, the rate of overrides by alert type, the reasons cited for overrides, and the appropriateness of those reasons. Overall, 73.3% of patient allergy, drug-drug interaction, and duplicate drug alerts were overridden, though the rate of overrides varied by alert type (P < .0001). About 60% of overrides were appropriate, and that proportion also varied by alert type (P < .0001). Few overrides of renal- (2.2%) or age-based (26.4%) medication substitutions were appropriate, while most duplicate drug (98%), patient allergy (96.5%), and formulary substitution (82.5%) alerts were appropriate. Despite warnings of potential significant harm, certain categories of alert overrides were inappropriate >75% of the time. The vast majority of duplicate drug, patient allergy, and formulary substitution alerts were appropriate, suggesting that these categories of alerts might be good targets for refinement to reduce alert fatigue. Almost three-quarters of alerts were overridden, and 40% of the overrides were not appropriate. Future research should optimize alert types and frequencies to increase their clinical relevance, reducing alert fatigue so that important alerts are not inappropriately overridden.

  3. Closed-form Static Analysis with Inertia Relief and Displacement-Dependent Loads Using a MSC/NASTRAN DMAP Alter

    NASA Technical Reports Server (NTRS)

    Barnett, Alan R.; Widrick, Timothy W.; Ludwiczak, Damian R.

    1995-01-01

    Solving for the displacements of free-free coupled systems acted upon by static loads is commonly performed throughout the aerospace industry. Many times, these problems are solved using static analysis with inertia relief. This solution technique allows for a free-free static analysis by balancing the applied loads with inertia loads generated by the applied loads. For some engineering applications, the displacements of the free-free coupled system induce additional static loads. Hence, the applied loads are equal to the original loads plus displacement-dependent loads. Solving for the final displacements of such systems is commonly performed using iterative solution techniques. Unfortunately, these techniques can be time-consuming and labor-intensive. Since the coupled system equations for free-free systems with displacement-dependent loads can be written in closed-form, it is advantageous to solve for the displacements in this manner. Implementing closed-form equations in static analysis with inertia relief is analogous to implementing transfer functions in dynamic analysis. Using a MSC/NASTRAN DMAP Alter, displacement-dependent loads have been included in static analysis with inertia relief. Such an Alter has been used successfully to solve efficiently a common aerospace problem typically solved using an iterative technique.

  4. Comparison of methods of alert acknowledgement by critical care clinicians in the ICU setting

    PubMed Central

    Harrison, Andrew M.; Thongprayoon, Charat; Aakre, Christopher A.; Jeng, Jack Y.; Dziadzko, Mikhail A.; Gajic, Ognjen; Pickering, Brian W.

    2017-01-01

    Background Electronic Health Record (EHR)-based sepsis alert systems have failed to demonstrate improvements in clinically meaningful endpoints. However, the effect of implementation barriers on the success of new sepsis alert systems is rarely explored. Objective To test the hypothesis time to severe sepsis alert acknowledgement by critical care clinicians in the ICU setting would be reduced using an EHR-based alert acknowledgement system compared to a text paging-based system. Study Design In one arm of this simulation study, real alerts for patients in the medical ICU were delivered to critical care clinicians through the EHR. In the other arm, simulated alerts were delivered through text paging. The primary outcome was time to alert acknowledgement. The secondary outcomes were a structured, mixed quantitative/qualitative survey and informal group interview. Results The alert acknowledgement rate from the severe sepsis alert system was 3% (N = 148) and 51% (N = 156) from simulated severe sepsis alerts through traditional text paging. Time to alert acknowledgement from the severe sepsis alert system was median 274 min (N = 5) and median 2 min (N = 80) from text paging. The response rate from the EHR-based alert system was insufficient to compare primary measures. However, secondary measures revealed important barriers. Conclusion Alert fatigue, interruption, human error, and information overload are barriers to alert and simulation studies in the ICU setting. PMID:28316887

  5. Comparison of methods of alert acknowledgement by critical care clinicians in the ICU setting.

    PubMed

    Harrison, Andrew M; Thongprayoon, Charat; Aakre, Christopher A; Jeng, Jack Y; Dziadzko, Mikhail A; Gajic, Ognjen; Pickering, Brian W; Herasevich, Vitaly

    2017-01-01

    Electronic Health Record (EHR)-based sepsis alert systems have failed to demonstrate improvements in clinically meaningful endpoints. However, the effect of implementation barriers on the success of new sepsis alert systems is rarely explored. To test the hypothesis time to severe sepsis alert acknowledgement by critical care clinicians in the ICU setting would be reduced using an EHR-based alert acknowledgement system compared to a text paging-based system. In one arm of this simulation study, real alerts for patients in the medical ICU were delivered to critical care clinicians through the EHR. In the other arm, simulated alerts were delivered through text paging. The primary outcome was time to alert acknowledgement. The secondary outcomes were a structured, mixed quantitative/qualitative survey and informal group interview. The alert acknowledgement rate from the severe sepsis alert system was 3% ( N  = 148) and 51% ( N  = 156) from simulated severe sepsis alerts through traditional text paging. Time to alert acknowledgement from the severe sepsis alert system was median 274 min ( N  = 5) and median 2 min ( N  = 80) from text paging. The response rate from the EHR-based alert system was insufficient to compare primary measures. However, secondary measures revealed important barriers. Alert fatigue, interruption, human error, and information overload are barriers to alert and simulation studies in the ICU setting.

  6. MO-F-16A-06: Implementation of a Radiation Exposure Monitoring System for Surveillance of Multi-Modality Radiation Dose Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stewart, B; Kanal, K; Dickinson, R

    2014-06-15

    Purpose: We have implemented a commercially available Radiation Exposure Monitoring System (REMS) to enhance the processes of radiation dose data collection, analysis and alerting developed over the past decade at our sites of practice. REMS allows for consolidation of multiple radiation dose information sources and quicker alerting than previously developed processes. Methods: Thirty-nine x-ray producing imaging modalities were interfaced with the REMS: thirteen computed tomography scanners, sixteen angiography/interventional systems, nine digital radiography systems and one mammography system. A number of methodologies were used to provide dose data to the REMS: Modality Performed Procedure Step (MPPS) messages, DICOM Radiation Dose Structuredmore » Reports (RDSR), and DICOM header information. Once interfaced, the dosimetry information from each device underwent validation (first 15–20 exams) before release for viewing by end-users: physicians, medical physicists, technologists and administrators. Results: Before REMS, our diagnostic physics group pulled dosimetry data from seven disparate databases throughout the radiology, radiation oncology, cardiology, electrophysiology, anesthesiology/pain management and vascular surgery departments at two major medical centers and four associated outpatient clinics. With the REMS implementation, we now have one authoritative source of dose information for alerting, longitudinal analysis, dashboard/graphics generation and benchmarking. REMS provides immediate automatic dose alerts utilizing thresholds calculated through daily statistical analysis. This has streamlined our Closing the Loop process for estimated skin exposures in excess of our institutional specific substantial radiation dose level which relied on technologist notification of the diagnostic physics group and daily report from the radiology information system (RIS). REMS also automatically calculates the CT size-specific dose estimate (SSDE) as well as provides two-dimensional angulation dose maps for angiography/interventional procedures. Conclusion: REMS implementation has streamlined and consolidated the dosimetry data collection and analysis process at our institutions while eliminating manual entry error and providing immediate alerting and access to dosimetry data to both physicists and physicians. Brent Stewart has funded research through GE Healthcare.« less

  7. Differential effects of phasic and tonic alerting on the efficiency of executive attention.

    PubMed

    Asanowicz, Dariusz; Marzecová, Anna

    2017-05-01

    The study examined how alerting and executive attention interact in a task involving conflict resolution. We proposed a tentative scenario in which an initial exogenous phasic alerting phase is followed by an endogenous tonic alerting phase, and hypothesized that these two processes may have distinct effects on conflict resolution. Phasic alerting was expected to increase the conflict, whereas tonic alerting was expected to decrease the conflict. Three experiments were conducted using different variants of the flanker task with visual alerting cues and varied cue-target intervals (SOA), to differentiate between effects of phasic alerting (short SOA) and tonic alerting (long SOA). The results showed that phasic alerting consistently decreased the efficiency of conflict resolution indexed by response time and accuracy, whereas tonic alerting increased the accuracy of conflict resolution, but at a cost in the speed of processing the conflict. The third experiment additionally showed that the effects of phasic alerting may be modulated by the psychophysical strength of alerting cues. Discussed are possible mechanisms that could account for the observed interactions between alerting and conflict resolution, as well as some discrepancies between the current and previous studies. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Optimizing the real-time ground level enhancement alert system based on neutron monitor measurements: Introducing GLE Alert Plus

    NASA Astrophysics Data System (ADS)

    Souvatzoglou, G.; Papaioannou, A.; Mavromichalaki, H.; Dimitroulakos, J.; Sarlanis, C.

    2014-11-01

    Whenever a significant intensity increase is being recorded by at least three neutron monitor stations in real-time mode, a ground level enhancement (GLE) event is marked and an automated alert is issued. Although, the physical concept of the algorithm is solid and has efficiently worked in a number of cases, the availability of real-time data is still an open issue and makes timely GLE alerts quite challenging. In this work we present the optimization of the GLE alert that has been set into operation since 2006 at the Athens Neutron Monitor Station. This upgrade has led to GLE Alert Plus, which is currently based upon the Neutron Monitor Database (NMDB). We have determined the critical values per station allowing us to issue reliable GLE alerts close to the initiation of the event while at the same time we keep the false alert rate at low levels. Furthermore, we have managed to treat the problem of data availability, introducing the Go-Back-N algorithm. A total of 13 GLE events have been marked from January 2000 to December 2012. GLE Alert Plus issued an alert for 12 events. These alert times are compared to the alert times of GOES Space Weather Prediction Center and Solar Energetic Particle forecaster of the University of Málaga (UMASEP). In all cases GLE Alert Plus precedes the GOES alert by ≈8-52 min. The comparison with UMASEP demonstrated a remarkably good agreement. Real-time GLE alerts by GLE Alert Plus may be retrieved by http://cosray.phys.uoa.gr/gle_alert_plus.html, http://www.nmdb.eu, and http://swe.ssa.esa.int/web/guest/space-radiation. An automated GLE alert email notification system is also available to interested users.

  9. Machine-learning-based Brokers for Real-time Classification of the LSST Alert Stream

    NASA Astrophysics Data System (ADS)

    Narayan, Gautham; Zaidi, Tayeb; Soraisam, Monika D.; Wang, Zhe; Lochner, Michelle; Matheson, Thomas; Saha, Abhijit; Yang, Shuo; Zhao, Zhenge; Kececioglu, John; Scheidegger, Carlos; Snodgrass, Richard T.; Axelrod, Tim; Jenness, Tim; Maier, Robert S.; Ridgway, Stephen T.; Seaman, Robert L.; Evans, Eric Michael; Singh, Navdeep; Taylor, Clark; Toeniskoetter, Jackson; Welch, Eric; Zhu, Songzhe; The ANTARES Collaboration

    2018-05-01

    The unprecedented volume and rate of transient events that will be discovered by the Large Synoptic Survey Telescope (LSST) demand that the astronomical community update its follow-up paradigm. Alert-brokers—automated software system to sift through, characterize, annotate, and prioritize events for follow-up—will be critical tools for managing alert streams in the LSST era. The Arizona-NOAO Temporal Analysis and Response to Events System (ANTARES) is one such broker. In this work, we develop a machine learning pipeline to characterize and classify variable and transient sources only using the available multiband optical photometry. We describe three illustrative stages of the pipeline, serving the three goals of early, intermediate, and retrospective classification of alerts. The first takes the form of variable versus transient categorization, the second a multiclass typing of the combined variable and transient data set, and the third a purity-driven subtyping of a transient class. Although several similar algorithms have proven themselves in simulations, we validate their performance on real observations for the first time. We quantitatively evaluate our pipeline on sparse, unevenly sampled, heteroskedastic data from various existing observational campaigns, and demonstrate very competitive classification performance. We describe our progress toward adapting the pipeline developed in this work into a real-time broker working on live alert streams from time-domain surveys.

  10. An IDS Alerts Aggregation Algorithm Based on Rough Set Theory

    NASA Astrophysics Data System (ADS)

    Zhang, Ru; Guo, Tao; Liu, Jianyi

    2018-03-01

    Within a system in which has been deployed several IDS, a great number of alerts can be triggered by a single security event, making real alerts harder to be found. To deal with redundant alerts, we propose a scheme based on rough set theory. In combination with basic concepts in rough set theory, the importance of attributes in alerts was calculated firstly. With the result of attributes importance, we could compute the similarity of two alerts, which will be compared with a pre-defined threshold to determine whether these two alerts can be aggregated or not. Also, time interval should be taken into consideration. Allowed time interval for different types of alerts is computed individually, since different types of alerts may have different time gap between two alerts. In the end of this paper, we apply proposed scheme on DAPRA98 dataset and the results of experiment show that our scheme can efficiently reduce the redundancy of alerts so that administrators of security system could avoid wasting time on useless alerts.

  11. Alertness and cognitive control: Toward a spatial grouping hypothesis.

    PubMed

    Schneider, Darryl W

    2018-05-01

    A puzzling interaction involving alertness and cognitive control is indicated by the finding of faster performance but larger congruency effects on alert trials (on which alerting cues are presented before the task stimuli) than on no-alert trials in selective attention tasks. In the present study, the author conducted four experiments to test hypotheses about the interaction. Manipulation of stimulus spacing revealed a difference in congruency effects between alert and no-alert trials for narrowly spaced stimuli but not for widely spaced stimuli, inconsistent with the hypothesis that increased alertness is associated with more diffuse attention. Manipulation of color grouping revealed similar differences in congruency effects between alert and no-alert trials for same-color and different-color groupings of targets and distractors, inconsistent with the general hypothesis that increased alertness is associated with more perceptual grouping. To explain the results, the author proposes that increased alertness is associated specifically with more spatial grouping of stimuli, possibly by modulating the threshold for parsing stimulus displays into distinct objects.

  12. Evaluation of Nursing Documentation Completion of Stroke Patients in the Emergency Department: A Pre-Post Analysis Using Flowsheet Templates and Clinical Decision Support.

    PubMed

    Richardson, Karen J; Sengstack, Patricia; Doucette, Jeffrey N; Hammond, William E; Schertz, Matthew; Thompson, Julie; Johnson, Constance

    2016-02-01

    The primary aim of this performance improvement project was to determine whether the electronic health record implementation of stroke-specific nursing documentation flowsheet templates and clinical decision support alerts improved the nursing documentation of eligible stroke patients in seven stroke-certified emergency departments. Two system enhancements were introduced into the electronic record in an effort to improve nursing documentation: disease-specific documentation flowsheets and clinical decision support alerts. Using a pre-post design, project measures included six stroke management goals as defined by the National Institute of Neurological Disorders and Stroke and three clinical decision support measures based on entry of orders used to trigger documentation reminders for nursing: (1) the National Institutes of Health's Stroke Scale, (2) neurological checks, and (3) dysphagia screening. Data were reviewed 6 months prior (n = 2293) and 6 months following the intervention (n = 2588). Fisher exact test was used for statistical analysis. Statistical significance was found for documentation of five of the six stroke management goals, although effect sizes were small. Customizing flowsheets to meet the needs of nursing workflow showed improvement in the completion of documentation. The effects of the decision support alerts on the completeness of nursing documentation were not statistically significant (likely due to lack of order entry). For example, an order for the National Institutes of Health Stroke Scale was entered only 10.7% of the time, which meant no alert would fire for nursing in the postintervention group. Future work should focus on decision support alerts that trigger reminders for clinicians to place relevant orders for this population.

  13. Managing the Alert Process at NewYork-Presbyterian Hospital

    PubMed Central

    Kuperman, Gilad J; Diamente, Rosanna; Khatu, Vrinda; Chan-Kraushar, Terri; Stetson, Pete; Boyer, Aurelia; Cooper, Mary

    2005-01-01

    Clinical decision support can improve the quality of care, but requires substantial knowledge management activities. At NewYork-Presbyterian Hospital in New York City, we have implemented a formal alert management process whereby only hospital committees and departments can request alerts. An explicit requestor, who will help resolve the details of the alert logic and the alert message must be identified. Alerts must be requested in writing using a structured alert request form. Alert requests are reviewed by the Alert Committee and then forwarded to the Information Systems department for a software development estimate. The model required that clinical committees and departments become more actively involved in the development of alerts than had previously been necessary. In the 12 months following implementation, 10 alert requests were received. The model has been well received. A lot of the knowledge engineering work has been distributed and burden has been removed from scarce medical informatics resources. PMID:16779073

  14. Optimizing drug-dose alerts using commercial software throughout an integrated health care system.

    PubMed

    Saiyed, Salim M; Greco, Peter J; Fernandes, Glenn; Kaelber, David C

    2017-11-01

    All default electronic health record and drug reference database vendor drug-dose alerting recommendations (single dose, daily dose, dose frequency, and dose duration) were silently turned on in inpatient, outpatient, and emergency department areas for pediatric-only and nonpediatric-only populations. Drug-dose alerts were evaluated during a 3-month period. Drug-dose alerts fired on 12% of orders (104 098/834 911). System-level and drug-specific strategies to decrease drug-dose alerts were analyzed. System-level strategies included: (1) turning off all minimum drug-dosing alerts, (2) turning off all incomplete information drug-dosing alerts, (3) increasing the maximum single-dose drug-dose alert threshold to 125%, (4) increasing the daily dose maximum drug-dose alert threshold to 125%, and (5) increasing the dose frequency drug-dose alert threshold to more than 2 doses per day above initial threshold. Drug-specific strategies included changing drug-specific maximum single and maximum daily drug-dose alerting parameters for the top 22 drug categories by alert frequency. System-level approaches decreased alerting to 5% (46 988/834 911) and drug-specific approaches decreased alerts to 3% (25 455/834 911). Drug-dose alerts varied between care settings and patient populations. © The Author 2017. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  15. A systematic review of the effectiveness of interruptive medication prescribing alerts in hospital CPOE systems to change prescriber behavior and improve patient safety.

    PubMed

    Page, N; Baysari, M T; Westbrook, J I

    2017-09-01

    To assess the evidence of the effectiveness of different categories of interruptive medication prescribing alerts to change prescriber behavior and/or improve patient outcomes in hospital computerized provider order entry (CPOE) systems. PubMed, Embase, CINAHL and the Cochrane Library were searched for relevant articles published between January 2000 and February 2016. Studies were included if they compared the outcomes of automatic, interruptive medication prescribing alert/s to a control/comparison group to determine alert effectiveness. Twenty-three studies describing 32 alerts classified into 11 alert categories were identified. The most common alert categories studied were drug-condition interaction (n=6), drug-drug interaction alerts (n=6) and corollary order alerts (n=6). All 23 papers investigated the effect of the intervention alert on at least one outcome measure of prescriber behavior. Just over half of the studies (53%, n=17) reported a statistically significant beneficial effect from the intervention alert; 34% (n=11) reported no statistically significant effect, and 6% (n=2) reported a significant detrimental effect. Two studies also evaluated the effect of alerts on patient outcome measures; neither finding that patient outcomes significantly improved following alert implementation (6%, n=2). The greatest volume of evidence relates to three alert categories: drug-condition, drug-drug and corollary order alerts. Of these, drug-condition alerts had the greatest number of studies reporting positive effects (five out of six studies). Only two of six studies of drug-drug interaction and one of six of corollary alerts reported positive benefits. The current evidence-base does not show a clear indication that particular categories of alerts are more effective than others. While the majority of alert categories were shown to improve outcomes in some studies, there were also many cases where outcomes did not improve. This lack of evidence hinders decisions about the amount and type of decision support that should be integrated into CPOE systems to increase safety while reducing the risk of alert fatigue. Virtually no studies have sought to investigate the impact on changes to prescriber behavior and outcomes overall when alerts from multiple categories are incorporated within the same system. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. NASA Runway Incursion Prevention System (RIPS) Dallas-Fort Worth Demonstration Performance Analysis

    NASA Technical Reports Server (NTRS)

    Cassell, Rick; Evers, Carl; Esche, Jeff; Sleep, Benjamin; Jones, Denise R. (Technical Monitor)

    2002-01-01

    NASA's Aviation Safety Program Synthetic Vision System project conducted a Runway Incursion Prevention System (RIPS) flight test at the Dallas-Fort Worth International Airport in October 2000. The RIPS research system includes advanced displays, airport surveillance system, data links, positioning system, and alerting algorithms to provide pilots with enhanced situational awareness, supplemental guidance cues, a real-time display of traffic information, and warnings of runway incursions. This report describes the aircraft and ground based runway incursion alerting systems and traffic positioning systems (Automatic Dependent Surveillance - Broadcast (ADS-B) and Traffic Information Service - Broadcast (TIS-B)). A performance analysis of these systems is also presented.

  17. Evaluation of Antimicrobial Stewardship-Related Alerts Using a Clinical Decision Support System.

    PubMed

    Ghamrawi, Riane J; Kantorovich, Alexander; Bauer, Seth R; Pallotta, Andrea M; Sekeres, Jennifer K; Gordon, Steven M; Neuner, Elizabeth A

    2017-11-01

    Background: Information technology, including clinical decision support systems (CDSS), have an increasingly important and growing role in identifying opportunities for antimicrobial stewardship-related interventions. Objective: The aim of this study was to describe and compare types and outcomes of CDSS-built antimicrobial stewardship alerts. Methods: Fifteen alerts were evaluated in the initial antimicrobial stewardship program (ASP) review. Preimplementation, alerts were reviewed retrospectively. Postimplementation, alerts were reviewed in real-time. Data collection included total number of actionable alerts, recommendation acceptance rates, and time spent on each alert. Time to de-escalation to narrower spectrum agents was collected. Results: In total, 749 alerts were evaluated. Overall, 306 (41%) alerts were actionable (173 preimplementation, 133 postimplementation). Rates of actionable alerts were similar for custom-built and prebuilt alert types (39% [53 of 135] vs 41% [253 of 614], P = .68]. In the postimplementation group, an intervention was attempted in 97% of actionable alerts and 70% of interventions were accepted. The median time spent per alert was 7 minutes (interquartile range [IQR], 5-13 minutes; 15 [12-17] minutes for actionable alerts vs 6 [5-7] minutes for nonactionable alerts, P < .001). In cases where the antimicrobial was eventually de-escalated, the median time to de-escalation was 28.8 hours (95% confidence interval [CI], 10.0-69.1 hours) preimplementation vs 4.7 hours (95% CI, 2.4-22.1 hours) postimplementation, P < .001. Conclusions: CDSS have played an important role in ASPs to help identify opportunities to optimize antimicrobial use through prebuilt and custom-built alerts. As ASP roles continue to expand, focusing time on customizing institution specific alerts will be of vital importance to help redistribute time needed to manage other ASP tasks and opportunities.

  18. Factors influencing alert acceptance: a novel approach for predicting the success of clinical decision support

    PubMed Central

    Seidling, Hanna M; Phansalkar, Shobha; Seger, Diane L; Paterno, Marilyn D; Shaykevich, Shimon; Haefeli, Walter E

    2011-01-01

    Background Clinical decision support systems can prevent knowledge-based prescription errors and improve patient outcomes. The clinical effectiveness of these systems, however, is substantially limited by poor user acceptance of presented warnings. To enhance alert acceptance it may be useful to quantify the impact of potential modulators of acceptance. Methods We built a logistic regression model to predict alert acceptance of drug–drug interaction (DDI) alerts in three different settings. Ten variables from the clinical and human factors literature were evaluated as potential modulators of provider alert acceptance. ORs were calculated for the impact of knowledge quality, alert display, textual information, prioritization, setting, patient age, dose-dependent toxicity, alert frequency, alert level, and required acknowledgment on acceptance of the DDI alert. Results 50 788 DDI alerts were analyzed. Providers accepted only 1.4% of non-interruptive alerts. For interruptive alerts, user acceptance positively correlated with frequency of the alert (OR 1.30, 95% CI 1.23 to 1.38), quality of display (4.75, 3.87 to 5.84), and alert level (1.74, 1.63 to 1.86). Alert acceptance was higher in inpatients (2.63, 2.32 to 2.97) and for drugs with dose-dependent toxicity (1.13, 1.07 to 1.21). The textual information influenced the mode of reaction and providers were more likely to modify the prescription if the message contained detailed advice on how to manage the DDI. Conclusion We evaluated potential modulators of alert acceptance by assessing content and human factors issues, and quantified the impact of a number of specific factors which influence alert acceptance. This information may help improve clinical decision support systems design. PMID:21571746

  19. A widening gap? Static and dynamic performance differences between specialist and general hospitals.

    PubMed

    Vera, Antonio; Petratos, Pythagoras; Salge, Torsten Oliver

    2018-03-01

    This paper develops and tests a dynamic model of hospital focus. It does so by tracing the performance trajectories of specialist and general hospitals to identify whether a performance gap exists and whether it widens or shrinks over time. Our longitudinal analyses of all hospital organizations within the English National Health Service (NHS) reveal not only a notable performance gap between specialist and general hospitals in particular with regards to patient satisfaction that widens over time, but also the emergence of a gap especially with regards to hospital staff job satisfaction. These findings reflect the considerable potential of specialization as a means to enhance hospital effectiveness. However, they also alert health policy makers to the threat of a widening performance gap between specialist and general hospitals with potential negative repercussions at the patient and health system level.

  20. Drowsy driver mobile application: Development of a novel scleral-area detection method.

    PubMed

    Mohammad, Faisal; Mahadas, Kausalendra; Hung, George K

    2017-10-01

    A reliable and practical app for mobile devices was developed to detect driver drowsiness. It consisted of two main components: a Haar cascade classifier, provided by a computer vision framework called OpenCV, for face/eye detection; and a dedicated JAVA software code for image processing that was applied over a masked region circumscribing the eye. A binary threshold was performed over the masked region to provide a quantitative measure of the number of white pixels in the sclera, which represented the state of eye opening. A continuously low white-pixel count would indicate drowsiness, thereby triggering an alarm to alert the driver. This system was successfully implemented on: (1) a static face image, (2) two subjects under laboratory conditions, and (3) a subject in a vehicle environment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Expertise and responsibility effects on pilots' reactions to flight deck alerts in a simulator.

    PubMed

    Zheng, Yiyuan; Lu, Yanyu; Yang, Zheng; Fu, Shan

    2014-11-01

    Flight deck alerts provide system malfunction information designed to lead corresponding pilot reactions aimed at guaranteeing flight safety. This study examined the roles of expertise and flight responsibility and their relationship to pilots' reactions to flight deck alerts. There were 17 pilots composing 12 flight crews that were assigned into pairs according to flight hours and responsibilities. The experiment included 9 flight scenarios and was carried out in a CRJ-200 flight simulator. Pilot performance was recorded by a wide angle video camera, and four kinds of reactions to alerts were defined for analysis. Pilots tended to have immediate reactions to uninterrupted cautions, with a turning off rate as high as 75%. However, this rate decreased sharply when pilots encountered interrupted cautions and warnings; they also exhibited many wrong reactions to warnings. Pilots with more expertise had more reactions to uninterrupted cautions than those with less expertise, both as pilot flying and pilot monitoring. Meanwhile, the pilot monitoring, regardless of level of expertise, exhibited more reactions than the pilot flying. In addition, more experienced pilots were more likely to have wrong reactions to warnings while acting as the monitoring pilot. These results suggest that both expertise and flight responsibility influence pilots' reactions to alerts. Considering crew pairing strategy, when a pilot flying is a less experienced pilot, a more experience pilot is suggested to be the monitoring pilot. The results of this study have implications for understanding pilots' behaviors to flight deck alerts, calling for specialized training and design of approach alarms on the flight deck.

  2. Development of a standardized, citywide process for managing smart-pump drug libraries.

    PubMed

    Walroth, Todd A; Smallwood, Shannon; Arthur, Karen; Vance, Betsy; Washington, Alana; Staublin, Therese; Haslar, Tammy; Reddan, Jennifer G; Fuller, James

    2018-06-15

    Development and implementation of an interprofessional consensus-driven process for review and optimization of smart-pump drug libraries and dosing limits are described. The Indianapolis Coalition for Patient Safety (ICPS), which represents 6 Indianapolis-area health systems, identified an opportunity to reduce clinically insignificant alerts that smart infusion pumps present to end users. Through a consensus-driven process, ICPS aimed to identify best practices to implement at individual hospitals in order to establish specific action items for smart-pump drug library optimization. A work group of pharmacists, nurses, and industrial engineers met to evaluate variability within and lack of scrutiny of smart-pump drug libraries. The work group used Lean Six Sigma methodologies to generate a list of key needs and barriers to be addressed in process standardization. The group reviewed targets for smart-pump drug library optimization, including dosing limits, types of alerts reviewed, policies, and safety best practices. The work group also analyzed existing processes at each site to develop a final consensus statement outlining a model process for reviewing alerts and managing smart-pump data. Analysis of the total number of alerts per device across ICPS-affiliated health systems over a 4-year period indicated a 50% decrease (from 7.2 to 3.6 alerts per device per month) after implementation of the model by ICPS member organizations. Through implementation of a standardized, consensus-driven process for smart-pump drug library optimization, ICPS member health systems reduced clinically insignificant smart-pump alerts. Copyright © 2018 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  3. Effect of air quality alerts on human health: a regression discontinuity analysis in Toronto, Canada.

    PubMed

    Chen, Hong; Li, Qiongsi; Kaufman, Jay S; Wang, Jun; Copes, Ray; Su, Yushan; Benmarhnia, Tarik

    2018-01-01

    Ambient air pollution is a major health risk globally. To reduce adverse health effects on days when air pollution is high, government agencies worldwide have implemented air quality alert programmes. Despite their widespread use, little is known about whether these programmes produce any observable public-health benefits. We assessed the effectiveness of such programmes using a quasi-experimental approach. We assembled a population-based cohort comprising all individuals who resided in the city of Toronto (Ontario, Canada) from 2003 to 2012 (about 2·6 million people). We ascertained seven health outcomes known to be affected by short-term elevation of air pollution, using provincial health administrative databases. These health outcomes were cardiovascular-related mortality, respiratory-related mortality, and hospital admissions or emergency-department visits for acute myocardial infarction, heart failure, stroke, asthma, and chronic obstructive pulmonary disease (COPD). We applied a regression discontinuity design to assess the effectiveness of an intervention (ie, the air quality alert programme). To quantify the effect of the air quality alert programme, we estimated for each outcome both the absolute rate difference and the rate ratio attributable to programme eligibility (by intention-to-treat analysis) and the alerts themselves (by two-stage regression approach), respectively. Between Jan 1, 2003, and Dec 31, 2012, on average between three and 27 daily cardiovascular or respiratory events were reported in Toronto (depending on the outcome). Alert announcements reduced asthma-related emergency-department visits by 4·73 cases per 1 000 000 people per day (95% CI 0·55-9·38), or in relative terms by 25% (95% CI 1-47). Programme eligibility also led to 2·05 (95% CI 0·07-4·00) fewer daily emergency-department visits for asthma. We did not detect a significant reduction in any other health outcome as a result of alert announcements or programme eligibility. However, a non-significant trend was noted towards decreased asthma-related and COPD-related admissions. In this population-based cohort, the air quality alert programme was related to some reductions in respiratory morbidity, but not any other health outcome examined. This finding suggests that issuing air quality alerts alone has a limited effect on public health and that implementing enforced public actions to reduce air pollution on high pollution days could be warranted. Together with accumulating evidence of substantial burden from long-term air pollution exposure, this study underscores the need for further strengthening of global efforts that can lead to long-term improvement of overall air quality. Public Health Ontario, Canadian Institutes for Health Research. Copyright © 2018 The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY-NC-ND 4.0 license. Published by Elsevier Ltd.. All rights reserved.

  4. The NAS Alert System: A look at the first eight years

    USGS Publications Warehouse

    Fuller, Pamela L.; Neilson, Matt; Huge, Dane H.

    2013-01-01

    The U.S. Geological Survey's Nonindigenous Aquatic Species (NAS) database program (http://nas.er.usgs.gov) tracks the distribution of introduced aquatic organisms across the United States. Awareness of, and timely response to, novel species introductions by those involved in nonindigenous aquatic species management and research requires a framework for rapid dissemination of occurrence data as it is incorporated into the NAS database. In May 2004, the NAS program developed an alert system to notify registered users of new introductions as part of a national early detection/rapid response system. This article summarizes information on system users and dispatched alerts from the system's inception through the end of 2011. The NAS alert system has registered over 1,700 users, with approximately 800 current subscribers. A total of 1,189 alerts had been transmitted through 2011. More alerts were sent for Florida (134 alerts) than for any other state. Fishes comprise the largest taxonomic group of alerts (440), with mollusks, plants, and crustaceans each containing over 100 alerts. Most alerts were for organisms that were intentionally released (414 alerts), with shipping, escape from captivity, and hitchhiking also representing major vectors. To explore the archive of sent alerts and to register, the search and signup page for the alert system can be found online at http://nas.er.usgs.gov/AlertSystem/default.aspx.

  5. MSC/NASTRAN DMAP Alter Used for Closed-Form Static Analysis With Inertia Relief and Displacement-Dependent Loads

    NASA Technical Reports Server (NTRS)

    1996-01-01

    Solving for the displacements of free-free coupled systems acted upon by static loads is a common task in the aerospace industry. Often, these problems are solved by static analysis with inertia relief. This technique allows for a free-free static analysis by balancing the applied loads with the inertia loads generated by the applied loads. For some engineering applications, the displacements of the free-free coupled system induce additional static loads. Hence, the applied loads are equal to the original loads plus the displacement-dependent loads. A launch vehicle being acted upon by an aerodynamic loading can have such applied loads. The final displacements of such systems are commonly determined with iterative solution techniques. Unfortunately, these techniques can be time consuming and labor intensive. Because the coupled system equations for free-free systems with displacement-dependent loads can be written in closed form, it is advantageous to solve for the displacements in this manner. Implementing closed-form equations in static analysis with inertia relief is analogous to implementing transfer functions in dynamic analysis. An MSC/NASTRAN (MacNeal-Schwendler Corporation/NASA Structural Analysis) DMAP (Direct Matrix Abstraction Program) Alter was used to include displacement-dependent loads in static analysis with inertia relief. It efficiently solved a common aerospace problem that typically has been solved with an iterative technique.

  6. Applying human factors principles to alert design increases efficiency and reduces prescribing errors in a scenario-based simulation

    PubMed Central

    Russ, Alissa L; Zillich, Alan J; Melton, Brittany L; Russell, Scott A; Chen, Siying; Spina, Jeffrey R; Weiner, Michael; Johnson, Elizabette G; Daggy, Joanne K; McManus, M Sue; Hawsey, Jason M; Puleo, Anthony G; Doebbeling, Bradley N; Saleem, Jason J

    2014-01-01

    Objective To apply human factors engineering principles to improve alert interface design. We hypothesized that incorporating human factors principles into alerts would improve usability, reduce workload for prescribers, and reduce prescribing errors. Materials and methods We performed a scenario-based simulation study using a counterbalanced, crossover design with 20 Veterans Affairs prescribers to compare original versus redesigned alerts. We redesigned drug–allergy, drug–drug interaction, and drug–disease alerts based upon human factors principles. We assessed usability (learnability of redesign, efficiency, satisfaction, and usability errors), perceived workload, and prescribing errors. Results Although prescribers received no training on the design changes, prescribers were able to resolve redesigned alerts more efficiently (median (IQR): 56 (47) s) compared to the original alerts (85 (71) s; p=0.015). In addition, prescribers rated redesigned alerts significantly higher than original alerts across several dimensions of satisfaction. Redesigned alerts led to a modest but significant reduction in workload (p=0.042) and significantly reduced the number of prescribing errors per prescriber (median (range): 2 (1–5) compared to original alerts: 4 (1–7); p=0.024). Discussion Aspects of the redesigned alerts that likely contributed to better prescribing include design modifications that reduced usability-related errors, providing clinical data closer to the point of decision, and displaying alert text in a tabular format. Displaying alert text in a tabular format may help prescribers extract information quickly and thereby increase responsiveness to alerts. Conclusions This simulation study provides evidence that applying human factors design principles to medication alerts can improve usability and prescribing outcomes. PMID:24668841

  7. Applying human factors principles to alert design increases efficiency and reduces prescribing errors in a scenario-based simulation.

    PubMed

    Russ, Alissa L; Zillich, Alan J; Melton, Brittany L; Russell, Scott A; Chen, Siying; Spina, Jeffrey R; Weiner, Michael; Johnson, Elizabette G; Daggy, Joanne K; McManus, M Sue; Hawsey, Jason M; Puleo, Anthony G; Doebbeling, Bradley N; Saleem, Jason J

    2014-10-01

    To apply human factors engineering principles to improve alert interface design. We hypothesized that incorporating human factors principles into alerts would improve usability, reduce workload for prescribers, and reduce prescribing errors. We performed a scenario-based simulation study using a counterbalanced, crossover design with 20 Veterans Affairs prescribers to compare original versus redesigned alerts. We redesigned drug-allergy, drug-drug interaction, and drug-disease alerts based upon human factors principles. We assessed usability (learnability of redesign, efficiency, satisfaction, and usability errors), perceived workload, and prescribing errors. Although prescribers received no training on the design changes, prescribers were able to resolve redesigned alerts more efficiently (median (IQR): 56 (47) s) compared to the original alerts (85 (71) s; p=0.015). In addition, prescribers rated redesigned alerts significantly higher than original alerts across several dimensions of satisfaction. Redesigned alerts led to a modest but significant reduction in workload (p=0.042) and significantly reduced the number of prescribing errors per prescriber (median (range): 2 (1-5) compared to original alerts: 4 (1-7); p=0.024). Aspects of the redesigned alerts that likely contributed to better prescribing include design modifications that reduced usability-related errors, providing clinical data closer to the point of decision, and displaying alert text in a tabular format. Displaying alert text in a tabular format may help prescribers extract information quickly and thereby increase responsiveness to alerts. This simulation study provides evidence that applying human factors design principles to medication alerts can improve usability and prescribing outcomes. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  8. Provider acceptance of an automated electronic alert for acute kidney injury

    PubMed Central

    Oh, Janice; Bia, Joshua R.; Ubaid-Ullah, Muhamad; Testani, Jeffrey M.; Wilson, Francis Perry

    2016-01-01

    Background Clinical decision support systems, including electronic alerts, ideally provide immediate and relevant patient-specific information to improve clinical decision-making. Despite the growing capabilities of such alerts in conjunction with an expanding electronic medical record, there is a paucity of information regarding their perceived usefulness. We surveyed healthcare providers' opinions concerning the practicality and efficacy of a specific text-based automated electronic alert for acute kidney injury (AKI) in a single hospital during a randomized trial of AKI alerts. Methods Providers who had received at least one electronic AKI alert in the previous 6 months, as part of a separate randomized controlled trial (clinicaltrials.gov #01862419), were asked to complete a survey concerning their opinions about this specific AKI alert system. Individual approval of the alert system was defined by a provider's desire to continue receiving the alert after termination of the trial. Results A total of 98 individuals completed the survey, including 62 physicians, 27 pharmacists and 7 non-physician providers. Sixty-nine percent of responders approved the alert, with no significant difference among the various professions (P = 0.28). Alert approval was strongly correlated with the belief that the alerts improved patient care (P < 0.0001), and negatively correlated with the belief that alerts did not provide novel information (P = 0.0001). With each additional 30 days of trial duration, odds of approval decreased by 20% (3–35%) (P = 0.02). Conclusions The alert system was generally well received, although approval waned with time. Approval was correlated with the belief that this type of alert improved patient care. These findings suggest that perceived efficacy is critical to the success of future alert trials. PMID:27478598

  9. Making electronic prescribing alerts more effective: scenario-based experimental study in junior doctors

    PubMed Central

    Shah, Priya; Wyatt, Jeremy C; Makubate, Boikanyo; Cross, Frank W

    2011-01-01

    Objective Expert authorities recommend clinical decision support systems to reduce prescribing error rates, yet large numbers of insignificant on-screen alerts presented in modal dialog boxes persistently interrupt clinicians, limiting the effectiveness of these systems. This study compared the impact of modal and non-modal electronic (e-) prescribing alerts on prescribing error rates, to help inform the design of clinical decision support systems. Design A randomized study of 24 junior doctors each performing 30 simulated prescribing tasks in random order with a prototype e-prescribing system. Using a within-participant design, doctors were randomized to be shown one of three types of e-prescribing alert (modal, non-modal, no alert) during each prescribing task. Measurements The main outcome measure was prescribing error rate. Structured interviews were performed to elicit participants' preferences for the prescribing alerts and their views on clinical decision support systems. Results Participants exposed to modal alerts were 11.6 times less likely to make a prescribing error than those not shown an alert (OR 11.56, 95% CI 6.00 to 22.26). Those shown a non-modal alert were 3.2 times less likely to make a prescribing error (OR 3.18, 95% CI 1.91 to 5.30) than those not shown an alert. The error rate with non-modal alerts was 3.6 times higher than with modal alerts (95% CI 1.88 to 7.04). Conclusions Both kinds of e-prescribing alerts significantly reduced prescribing error rates, but modal alerts were over three times more effective than non-modal alerts. This study provides new evidence about the relative effects of modal and non-modal alerts on prescribing outcomes. PMID:21836158

  10. Use of a novel electronic maternal surveillance system to generate automated alerts on the labor and delivery unit.

    PubMed

    Klumpner, Thomas T; Kountanis, Joanna A; Langen, Elizabeth S; Smith, Roger D; Tremper, Kevin K

    2018-06-26

    Maternal early warning systems reduce maternal morbidity. We developed an electronic maternal surveillance system capable of visually summarizing the labor and delivery census and identifying changes in clinical status. Automatic page alerts to clinical providers, using an algorithm developed at our institution, were incorporated in an effort to improve early detection of maternal morbidity. We report the frequency of pages generated by the system. To our knowledge, this is the first time such a system has been used in peripartum care. Alert criteria were developed after review of maternal early warning systems, including the Maternal Early Warning Criteria (MEWC). Careful consideration was given to the frequency of pages generated by the surveillance system. MEWC notification criteria were liberalized and a paging algorithm was created that triggered paging alerts to first responders (nurses) and then managing services due to the assumption that paging all clinicians for each vital sign triggering MEWC would generate an inordinate number of pages. For preliminary analysis, to determine the effect of our automated paging algorithm on alerting frequency, the paging frequency of this system was compared to the frequency of vital signs meeting the Maternal Early Warning Criteria (MEWC). This retrospective analysis was limited to a sample of 34 patient rooms uniquely capable of storing every vital sign reported by the bedside monitor. Over a 91-day period, from April 1 to July 1, 2017, surveillance was conducted from 64 monitored beds, and the obstetrics service received one automated page every 2.3 h. The most common triggers for alerts were for hypertension and tachycardia. For the subset of 34 patient rooms uniquely capable of real-time recording, one vital sign met the MEWC every 9.6 to 10.3 min. Anecdotally, the system was well-received. This novel electronic maternal surveillance system is designed to reduce cognitive bias and improve timely clinical recognition of maternal deterioration. The automated paging algorithm developed for this software dramatically reduces paging frequency compared to paging for isolated vital sign abnormalities alone. Long-term, prospective studies will be required to determine its impact on patient outcomes.

  11. Visual perception affected by motivation and alertness controlled by a noninvasive brain-computer interface.

    PubMed

    Maksimenko, Vladimir A; Runnova, Anastasia E; Zhuravlev, Maksim O; Makarov, Vladimir V; Nedayvozov, Vladimir; Grubov, Vadim V; Pchelintceva, Svetlana V; Hramov, Alexander E; Pisarchik, Alexander N

    2017-01-01

    The influence of motivation and alertness on brain activity associated with visual perception was studied experimentally using the Necker cube, which ambiguity was controlled by the contrast of its ribs. The wavelet analysis of recorded multichannel electroencephalograms (EEG) allowed us to distinguish two different scenarios while the brain processed the ambiguous stimulus. The first scenario is characterized by a particular destruction of alpha rhythm (8-12 Hz) with a simultaneous increase in beta-wave activity (20-30 Hz), whereas in the second scenario, the beta rhythm is not well pronounced while the alpha-wave energy remains unchanged. The experiments were carried out with a group of financially motivated subjects and another group of unpaid volunteers. It was found that the first scenario occurred mainly in the motivated group. This can be explained by the increased alertness of the motivated subjects. The prevalence of the first scenario was also observed in a group of subjects to whom images with higher ambiguity were presented. We believe that the revealed scenarios can occur not only during the perception of bistable images, but also in other perceptual tasks requiring decision making. The obtained results may have important applications for monitoring and controlling human alertness in situations which need substantial attention. On the base of the obtained results we built a brain-computer interface to estimate and control the degree of alertness in real time.

  12. External modulation of the sustained attention network in traumatic brain injury.

    PubMed

    Richard, Nadine M; O'Connor, Charlene; Dey, Ayan; Robertson, Ian H; Levine, Brian

    2018-05-07

    Traumatic brain injury (TBI) is associated with impairments in processing speed as well as higher-level cognitive functions that depend on distributed neural networks, such as regulating and sustaining attention. Although exogenous alerting cues have been shown to support patients in sustaining attentive, goal-directed behavior, the neural correlates of this rehabilitative effect are unclear. The purpose of this study was to explore the effects of moderate to severe TBI on activity and functional connectivity in the well-documented right-lateralized frontal-subcortical-parietal sustained attention network, and to assess the effects of alerting cues. Using multivariate analysis of fMRI data, TBI patients and matched neurologically healthy (NH) comparison participants were scanned as they performed the Sustained Attention to Response Task (SART) in 60-s blocks, with or without exogenous cueing through brief auditory alerting tones. Results documented inefficient voluntary control of attention in the TBI patients, with reduced functional connectivity in the sustained attention network relative to NH participants. When alerting cues were present during the SART, however, functional connectivity increased and became comparable to activity patterns seen in the NH group. These findings provide novel evidence of a neural mechanism for the facilitatory effects of alerting cues on goal-directed behavior in patients with damaged attentional brain systems, and support their use in cognitive rehabilitation. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  13. Applying mathematical models to predict resident physician performance and alertness on traditional and novel work schedules.

    PubMed

    Klerman, Elizabeth B; Beckett, Scott A; Landrigan, Christopher P

    2016-09-13

    In 2011 the U.S. Accreditation Council for Graduate Medical Education began limiting first year resident physicians (interns) to shifts of ≤16 consecutive hours. Controversy persists regarding the effectiveness of this policy for reducing errors and accidents while promoting education and patient care. Using a mathematical model of the effects of circadian rhythms and length of time awake on objective performance and subjective alertness, we quantitatively compared predictions for traditional intern schedules to those that limit work to ≤ 16 consecutive hours. We simulated two traditional schedules and three novel schedules using the mathematical model. The traditional schedules had extended duration work shifts (≥24 h) with overnight work shifts every second shift (including every third night, Q3) or every third shift (including every fourth night, Q4) night; the novel schedules had two different cross-cover (XC) night team schedules (XC-V1 and XC-V2) and a Rapid Cycle Rotation (RCR) schedule. Predicted objective performance and subjective alertness for each work shift were computed for each individual's schedule within a team and then combined for the team as a whole. Our primary outcome was the amount of time within a work shift during which a team's model-predicted objective performance and subjective alertness were lower than that expected after 16 or 24 h of continuous wake in an otherwise rested individual. The model predicted fewer hours with poor performance and alertness, especially during night-time work hours, for all three novel schedules than for either the traditional Q3 or Q4 schedules. Three proposed schedules that eliminate extended shifts may improve performance and alertness compared with traditional Q3 or Q4 schedules. Predicted times of worse performance and alertness were at night, which is also a time when supervision of trainees is lower. Mathematical modeling provides a quantitative comparison approach with potential to aid residency programs in schedule analysis and redesign.

  14. The effect of phasic auditory alerting on visual perception.

    PubMed

    Petersen, Anders; Petersen, Annemarie Hilkjær; Bundesen, Claus; Vangkilde, Signe; Habekost, Thomas

    2017-08-01

    Phasic alertness refers to a short-lived change in the preparatory state of the cognitive system following an alerting signal. In the present study, we examined the effect of phasic auditory alerting on distinct perceptual processes, unconfounded by motor components. We combined an alerting/no-alerting design with a pure accuracy-based single-letter recognition task. Computational modeling based on Bundesen's Theory of Visual Attention was used to examine the effect of phasic alertness on visual processing speed and threshold of conscious perception. Results show that phasic auditory alertness affects visual perception by increasing the visual processing speed and lowering the threshold of conscious perception (Experiment 1). By manipulating the intensity of the alerting cue, we further observed a positive relationship between alerting intensity and processing speed, which was not seen for the threshold of conscious perception (Experiment 2). This was replicated in a third experiment, in which pupil size was measured as a physiological marker of alertness. Results revealed that the increase in processing speed was accompanied by an increase in pupil size, substantiating the link between alertness and processing speed (Experiment 3). The implications of these results are discussed in relation to a newly developed mathematical model of the relationship between levels of alertness and the speed with which humans process visual information. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Preventing dispensing errors by alerting for drug confusions in the pharmacy information system-A survey of users.

    PubMed

    Campmans, Zizi; van Rhijn, Arianne; Dull, René M; Santen-Reestman, Jacqueline; Taxis, Katja; Borgsteede, Sander D

    2018-01-01

    Drug confusion is thought to be the most common type of dispensing error. Several strategies can be implemented to reduce the risk of medication errors. One of these are alerts in the pharmacy information system. To evaluate the experiences of pharmacists and pharmacy technicians with alerts for drug name and strength confusion. In May 2017, a cross-sectional survey of pharmacists and pharmacy technicians was performed in community pharmacies in the Netherlands using an online questionnaire. Of the 269 respondents, 86% (n = 230) had noticed the alert for drug name confusion, and 26% (n = 67) for drug strength confusion. Of those 230, 9% (n = 20) had experienced that the alert had prevented dispensing the wrong drug. For drug strength confusion, this proportion was 12% (n = 8). Respondents preferred to have an alert for drug name and strength confusion in the pharmacy information system. 'Alert fatigue' was an important issue, so alerts should only be introduced for frequent confusions or confusions with serious consequences. Pharmacists and pharmacy technicians were positive about having alerts for drug confusions in their pharmacy information system and experienced that alerts contributed to the prevention of dispensing errors. To prevent alert fatigue, it was considered important not to include all possible confusions as a new alert: the potential contribution to the prevention of drug confusion should be weighed against the risk of alert fatigue.

  16. Assessment of current AASHTO LRFD methods for static pile capacity analysis in Rhode Island soils.

    DOT National Transportation Integrated Search

    2013-07-01

    This report presents an assessment of current AASHTO LRFD methods for static pile capacity analysis in Rhode : Island soils. Current static capacity methods and associated resistance factors are based on pile load test data in sands : and clays. Some...

  17. Reducing duplicate testing: a comparison of two clinical decision support tools.

    PubMed

    Procop, Gary W; Keating, Catherine; Stagno, Paul; Kottke-Marchant, Kandice; Partin, Mary; Tuttle, Robert; Wyllie, Robert

    2015-05-01

    Unnecessary duplicate laboratory testing is common and costly. Systems-based means to avert unnecessary testing should be investigated and employed. We compared the effectiveness and cost savings associated with two clinical decision support tools to stop duplicate testing. The Hard Stop required telephone contact with the laboratory and justification to have the duplicate test performed, whereas the Smart Alert allowed the provider to bypass the alert at the point of order entry without justification. The Hard Stop alert was significantly more effective than the Smart Alert (92.3% vs 42.6%, respectively; P < .0001). The cost savings realized per alert activation was $16.08/alert for the Hard Stop alert vs $3.52/alert for the Smart Alert. Structural and process changes that require laboratory contact and justification for duplicate testing are more effective than interventions that allow providers to bypass alerts without justification at point of computerized physician order entry. Copyright© by the American Society for Clinical Pathology.

  18. Attentional networks and visuospatial working memory capacity in social anxiety.

    PubMed

    Moriya, Jun

    2018-02-01

    Social anxiety is associated with attentional bias and working memory for emotional stimuli; however, the ways in which social anxiety affects cognitive functions involving non-emotional stimuli remains unclear. The present study focused on the role of attentional networks (i.e. alerting, orienting, and executive control networks) and visuospatial working memory capacity (WMC) for non-emotional stimuli in the context of social anxiety. One hundred and seventeen undergraduates completed questionnaires on social anxiety. They then performed an attentional network test and a change detection task to measure visuospatial WMC. Orienting network and visuospatial WMC were positively correlated with social anxiety. A multiple regression analysis showed significant positive associations of alerting, orienting, and visuospatial WMC with social anxiety. Alerting, orienting networks, and high visuospatial WMC for non-emotional stimuli may predict degree of social anxiety.

  19. Intrusion-aware alert validation algorithm for cooperative distributed intrusion detection schemes of wireless sensor networks.

    PubMed

    Shaikh, Riaz Ahmed; Jameel, Hassan; d'Auriol, Brian J; Lee, Heejo; Lee, Sungyoung; Song, Young-Jae

    2009-01-01

    Existing anomaly and intrusion detection schemes of wireless sensor networks have mainly focused on the detection of intrusions. Once the intrusion is detected, an alerts or claims will be generated. However, any unidentified malicious nodes in the network could send faulty anomaly and intrusion claims about the legitimate nodes to the other nodes. Verifying the validity of such claims is a critical and challenging issue that is not considered in the existing cooperative-based distributed anomaly and intrusion detection schemes of wireless sensor networks. In this paper, we propose a validation algorithm that addresses this problem. This algorithm utilizes the concept of intrusion-aware reliability that helps to provide adequate reliability at a modest communication cost. In this paper, we also provide a security resiliency analysis of the proposed intrusion-aware alert validation algorithm.

  20. Intrusion-Aware Alert Validation Algorithm for Cooperative Distributed Intrusion Detection Schemes of Wireless Sensor Networks

    PubMed Central

    Shaikh, Riaz Ahmed; Jameel, Hassan; d’Auriol, Brian J.; Lee, Heejo; Lee, Sungyoung; Song, Young-Jae

    2009-01-01

    Existing anomaly and intrusion detection schemes of wireless sensor networks have mainly focused on the detection of intrusions. Once the intrusion is detected, an alerts or claims will be generated. However, any unidentified malicious nodes in the network could send faulty anomaly and intrusion claims about the legitimate nodes to the other nodes. Verifying the validity of such claims is a critical and challenging issue that is not considered in the existing cooperative-based distributed anomaly and intrusion detection schemes of wireless sensor networks. In this paper, we propose a validation algorithm that addresses this problem. This algorithm utilizes the concept of intrusion-aware reliability that helps to provide adequate reliability at a modest communication cost. In this paper, we also provide a security resiliency analysis of the proposed intrusion-aware alert validation algorithm. PMID:22454568

  1. Automated detection of optical counterparts to GRBs with RAPTOR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wozniak, P. R.; Vestrand, W. T.; Evans, S.

    2006-05-19

    The RAPTOR system (RAPid Telescopes for Optical Response) is an array of several distributed robotic telescopes that automatically respond to GCN localization alerts. Raptor-S is a 0.4-m telescope with 24 arc min. field of view employing a 1k x 1k Marconi CCD detector, and has already detected prompt optical emission from several GRBs within the first minute of the explosion. We present a real-time data analysis and alert system for automated identification of optical transients in Raptor-S GRB response data down to the sensitivity limit of {approx} 19 mag. Our custom data processing pipeline is designed to minimize the timemore » required to reliably identify transients and extract actionable information. The system utilizes a networked PostgreSQL database server for catalog access and distributes email alerts with successful detections.« less

  2. Network Analytical Tool for Monitoring Global Food Safety Highlights China

    PubMed Central

    Nepusz, Tamás; Petróczi, Andrea; Naughton, Declan P.

    2009-01-01

    Background The Beijing Declaration on food safety and security was signed by over fifty countries with the aim of developing comprehensive programs for monitoring food safety and security on behalf of their citizens. Currently, comprehensive systems for food safety and security are absent in many countries, and the systems that are in place have been developed on different principles allowing poor opportunities for integration. Methodology/Principal Findings We have developed a user-friendly analytical tool based on network approaches for instant customized analysis of food alert patterns in the European dataset from the Rapid Alert System for Food and Feed. Data taken from alert logs between January 2003 – August 2008 were processed using network analysis to i) capture complexity, ii) analyze trends, and iii) predict possible effects of interventions by identifying patterns of reporting activities between countries. The detector and transgressor relationships are readily identifiable between countries which are ranked using i) Google's PageRank algorithm and ii) the HITS algorithm of Kleinberg. The program identifies Iran, China and Turkey as the transgressors with the largest number of alerts. However, when characterized by impact, counting the transgressor index and the number of countries involved, China predominates as a transgressor country. Conclusions/Significance This study reports the first development of a network analysis approach to inform countries on their transgressor and detector profiles as a user-friendly aid for the adoption of the Beijing Declaration. The ability to instantly access the country-specific components of the several thousand annual reports will enable each country to identify the major transgressors and detectors within its trading network. Moreover, the tool can be used to monitor trading countries for improved detector/transgressor ratios. PMID:19688088

  3. Commercial Mobile Alert Service (CMAS) Alerting Pipeline Taxonomy

    DTIC Science & Technology

    2012-03-01

    for the consumer at the mo- ment but will soon become a commoditized, basic requirement. For example, as the baby boomers grow older, mobile services...Commercial Mobile Alert Service (CMAS) Alerting Pipeline Taxonomy The WEA Project Team March 2012 SPECIAL REPORT CMU/SEI-2012-TR-019 CERT...report presents a taxonomy developed for the Commercial Mobile Alert Service (CMAS). The CMAS Alerting Pipeline Taxonomy is a hierarchical classification

  4. Detection Of Malware Collusion With Static Dependence Analysis On Inter-App Communication

    DTIC Science & Technology

    2016-12-08

    DETECTION OF MALWARE COLLUSION WITH STATIC DEPENDENCE ANALYSIS ON INTER-APP COMMUNICATION VIRGINIA TECH DECEMBER 2016 FINAL TECHNICAL REPORT... DEPENDENCE ANALYSIS ON INTER-APP COMMUNICATION 5a. CONTRACT NUMBER FA8750-15-2-0076 5b. GRANT NUMBER N/A 5c. PROGRAM ELEMENT NUMBER 61101E 6. AUTHOR(S...exploited. 15. SUBJECT TERMS Malware Collusion; Inter-App Communication; Static Dependence Analysis 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF

  5. A Novel Design for Drug-Drug Interaction Alerts Improves Prescribing Efficiency.

    PubMed

    Russ, Alissa L; Chen, Siying; Melton, Brittany L; Johnson, Elizabette G; Spina, Jeffrey R; Weiner, Michael; Zillich, Alan J

    2015-09-01

    Drug-drug interactions (DDIs) are common in clinical care and pose serious risks for patients. Electronic health records display DDI alerts that can influence prescribers, but the interface design of DDI alerts has largely been unstudied. In this study, the objective was to apply human factors engineering principles to alert design. It was hypothesized that redesigned DDI alerts would significantly improve prescribers' efficiency and reduce prescribing errors. In a counterbalanced, crossover study with prescribers, two DDI alert designs were evaluated. Department of Veterans Affairs (VA) prescribers were video recorded as they completed fictitious patient scenarios, which included DDI alerts of varying severity. Efficiency was measured from time-stamped recordings. Prescribing errors were evaluated against predefined criteria. Efficiency and prescribing errors were analyzed with the Wilcoxon signed-rank test. Other usability data were collected on the adequacy of alert content, prescribers' use of the DDI monograph, and alert navigation. Twenty prescribers completed patient scenarios for both designs. Prescribers resolved redesigned alerts in about half the time (redesign: 52 seconds versus original design: 97 seconds; p<.001). Prescribing errors were not significantly different between the two designs. Usability results indicate that DDI alerts might be enhanced by facilitating easier access to laboratory data and dosing information and by allowing prescribers to cancel either interacting medication directly from the alert. Results also suggest that neither design provided adequate information for decision making via the primary interface. Applying human factors principles to DDI alerts improved overall efficiency. Aspects of DDI alert design that could be further enhanced prior to implementation were also identified.

  6. Reduction in alert fatigue in an assisted electronic prescribing system, through the Lean Six Sigma methodology.

    PubMed

    Cuéllar Monreal, Mª Jesús; Reig Aguado, Jorge; Font Noguera, Isabel; Poveda Andrés, José Luis

    2017-01-01

    To reduce the alert fatigue in our Assisted Electronic Prescribing System (AEPS), through the Lean Six Sigma (LSS) methodology. An observational (transversal) and retrospective study, in a general hospital with 850 beds and AEPS. The LSS methodology was followed in order to evaluate the alert fatigue situation in the AEPS system, to implement improvements, and to assess outcomes. The alerts generated during two trimesters studied (before and after the intervention) were analyzed. In order to measure the qualitative indicators, the most frequent alert types were analyzed, as well as the molecules responsible for over 50% of each type of alert. The action by the prescriber was analyzed in a sample of 496 prescriptions that generated such alerts. For each type of alert and molecule, there was a prioritization of the improvements to be implemented according to the alert generated and its quality. A second survey evaluated the pharmacist action for the alerts most highly valued by physicians. The problem, the objective, the work team and the project schedule were defined. A survey was designed in order to understand the opinion of the client about the alert system in the program. Based on the surveys collected (n = 136), the critical characteristics and the quanti/qualitative indicators were defined. Sixty (60) fields in the alert system were modified, corresponding to 32 molecules, and this led to a 28% reduction in the total number of alerts. Regarding quality indicators, false po sitive results were reduced by 25% (p < 0.05), 100% of those alerts ignored with justification were sustained, and there were no significant differences in user adherence to the system. The project improvements and outcomes were reviewed by the work team. LSS methodology has demonstrated being a valid tool for the quantitative and qualitative improvement of the alert system in an Assisted Electronic Prescription Program, thus reducing alert fatigue. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  7. 76 FR 80780 - Review of the Emergency Alert System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-27

    ... Emergency Alert System AGENCY: Federal Communications Commission. ACTION: Final rule. SUMMARY: In this document, the Commission amends its rules governing the Emergency Alert System (EAS) rules to extend the deadline for EAS Participants to be able to receive Common Alerting Protocol (CAP)- formatted EAS alerts to...

  8. To act or not to act: responses to electronic health record prompts by family medicine clinicians.

    PubMed

    Zazove, Philip; McKee, Michael; Schleicher, Lauren; Green, Lee; Kileny, Paul; Rapai, Mary; Mulhem, Elie

    2017-03-01

    A major focus of health care today is a strong emphasis on improving the health and quality of care for entire patient populations. One common approach utilizes electronic clinical alerts to prompt clinicians when certain interventions are due for individual patients being seen. However, these alerts have not been consistently effective, particularly for less visible (though important) conditions such as hearing loss (HL) screening. We conducted hour-long cognitive task analysis interviews to explore how family medicine clinicians view, perceive, and use electronic clinical alerts, and to utilize this information to design a more effective alert using HL identification and referral as a model diagnosis. Four key direct barriers were identified that impeded alert use: poor standardization and formatting, time pressures in primary care, clinic workflow variations, and mental models of the condition being prompted (in this case, HL). One indirect barrier was identified: electronic health record and institution/government regulations. We identified that clinicians' mental model of the condition being prompted was probably the major barrier, though this was often expressed as time pressure. We discuss solutions to each of the 5 identified barriers, such as addressing physicians' mental models, by focusing on physicians' expertise rather than knowledge to improve their comfort when caring for patients with the conditions being prompted. To unleash the potential of electronic clinical alerts, electronic health record and health care institutions need to address some key barriers. We outline these barriers and propose solutions. © The Author 2017. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  9. The effectiveness of computerized drug-lab alerts: a systematic review and meta-analysis.

    PubMed

    Bayoumi, Imaan; Al Balas, Mosab; Handler, Steven M; Dolovich, Lisa; Hutchison, Brian; Holbrook, Anne

    2014-06-01

    Inadequate lab monitoring of drugs is a potential cause of ADEs (adverse drug events) which is remediable. To determine the effectiveness of computerized drug-lab alerts to improve medication-related outcomes. Citations from the Computerized Clinical Decision Support System Systematic Review (CCDSSR) and MMIT (Medications Management through Health Information Technology) databases, which had searched MEDLINE, EMBASE, CINAHL, Cochrane Database of Systematic Reviews, International Pharmaceutical Abstracts from 1974 to March 27, 2013. Randomized controlled trials (RCTs) of clinician-targeted computerized drug lab alerts conducted in any healthcare setting. Two reviewers performed full text review to determine study eligibility. A single reviewer abstracted data and evaluated validity of included studies using Cochrane handbook domains. Thirty-six studies met the inclusion criteria (25 single drug studies with 22,504 participants, 14 targeting anticoagulation; 11 multi-drug studies with 56,769 participants). ADEs were reported as an outcome in only four trials, all targeting anticoagulants. Computerized drug-lab alerts did not reduce ADEs (OR 0.89, 95% CI 0.79-1.00, p=0.05), length of hospital stay (SMD 0.00, 95%CI -0.93 to 0.93, p=0.055, 1 study), likelihood of hypoglycemia (OR 1.29, 95% CI 0.31-5.37) or likelihood of bleeding, but were associated with increased likelihood of prescribing changes (OR 1.73, 95% CI 1.21-2.47) or lab monitoring (OR 1.47, 95% confidence interval 1.12-1.94) in accordance with the alert. There is no evidence that computerized drug-lab alerts are associated with important clinical benefits, but there is evidence of improvement in selected clinical surrogate outcomes (time in therapeutic range for vitamin K antagonists), and changes in process outcomes (lab monitoring and prescribing decisions). Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  10. Development and use of active clinical decision support for preemptive pharmacogenomics

    PubMed Central

    Bell, Gillian C; Crews, Kristine R; Wilkinson, Mark R; Haidar, Cyrine E; Hicks, J Kevin; Baker, Donald K; Kornegay, Nancy M; Yang, Wenjian; Cross, Shane J; Howard, Scott C; Freimuth, Robert R; Evans, William E; Broeckel, Ulrich; Relling, Mary V; Hoffman, James M

    2014-01-01

    Background Active clinical decision support (CDS) delivered through an electronic health record (EHR) facilitates gene-based drug prescribing and other applications of genomics to patient care. Objective We describe the development, implementation, and evaluation of active CDS for multiple pharmacogenetic test results reported preemptively. Materials and methods Clinical pharmacogenetic test results accompanied by clinical interpretations are placed into the patient's EHR, typically before a relevant drug is prescribed. Problem list entries created for high-risk phenotypes provide an unambiguous trigger for delivery of post-test alerts to clinicians when high-risk drugs are prescribed. In addition, pre-test alerts are issued if a very-high risk medication is prescribed (eg, a thiopurine), prior to the appropriate pharmacogenetic test result being entered into the EHR. Our CDS can be readily modified to incorporate new genes or high-risk drugs as they emerge. Results Through November 2012, 35 customized pharmacogenetic rules have been implemented, including rules for TPMT with azathioprine, thioguanine, and mercaptopurine, and for CYP2D6 with codeine, tramadol, amitriptyline, fluoxetine, and paroxetine. Between May 2011 and November 2012, the pre-test alerts were electronically issued 1106 times (76 for thiopurines and 1030 for drugs metabolized by CYP2D6), and the post-test alerts were issued 1552 times (1521 for TPMT and 31 for CYP2D6). Analysis of alert outcomes revealed that the interruptive CDS appropriately guided prescribing in 95% of patients for whom they were issued. Conclusions Our experience illustrates the feasibility of developing computational systems that provide clinicians with actionable alerts for gene-based drug prescribing at the point of care. PMID:23978487

  11. NOAA Weather Wire Service

    Science.gov Websites

    & Imagery; includes NWS alerts and warnings No 6 Wireless Emergency Alerts (WEA) Mobile Phone Alerts & Warnings only No 7 Interactive NWS (iNWS) - NOTE 1 https://inws.ncep.noaa.gov/ Mobile Phone $$$$) Internet/ Mobile Phone Alerts and Warnings No 15 County or Local Emergency Management Telephone alert

  12. 75 FR 26196 - Publication of OIG Updated Special Fraud Alert on Telemarketing by Durable Medical Equipment...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-11

    ... Special Fraud Alert on Telemarketing by Durable Medical Equipment Suppliers AGENCY: Office of Inspector... Special Fraud Alert. Specifically, the Updated Special Fraud Alert addressed the statutory provision...) 205-0007. SUPPLEMENTARY INFORMATION: In our publication of the OIG Updated Special Fraud Alert on...

  13. Physician Perspectives of CYP2C19 and Clopidogrel Drug-Gene Interaction Active Clinical Decision Support Alerts

    PubMed Central

    Nishimura, Adam A.; Shirts, Brian H.; Salama, Joseph; Smith, Joe W.; Devine, Beth; Tarczy-Hornoch, Peter

    2015-01-01

    Objective To determine if physicians find clinical decision support alerts for pharmacogenomic drug-gene interactions useful and assess their perceptions of usability aspects that impact usefulness. Materials and Methods 52 physicians participated in an online simulation and questionnaire involving a prototype alert for the clopidogrel and CYP2C19 drug-gene interaction. Results Only 4% of participants stated they would override the alert. 92% agreed that the alerts were useful. 87% found the visual interface appropriate, 91% felt the timing of the alert was appropriate and 75% were unfamiliar with the specific drug-gene interaction. 80% of providers preferred the ability to order the recommended medication within the alert. Qualitative responses suggested that supplementary information is important, but should be provided as external links, and that the utility of pharmacogenomic alerts depends on the broader ecosystem of alerts. Principal Conclusions Pharmacogenomic alerts would be welcomed by many physicians, can be built with minimalist design principles, and are appropriately placed at the end of the prescribing process. Since many physicians lack familiarity with pharmacogenomics but have limited time, information and educational resources within the alert should be carefully selected and presented in concise ways. PMID:26642939

  14. Physician perspectives of CYP2C19 and clopidogrel drug-gene interaction active clinical decision support alerts.

    PubMed

    Nishimura, Adam A; Shirts, Brian H; Salama, Joseph; Smith, Joe W; Devine, Beth; Tarczy-Hornoch, Peter

    2016-02-01

    To determine if physicians find clinical decision support alerts for pharmacogenomic drug-gene interactions useful and assess their perceptions of usability aspects that impact usefulness. 52 physicians participated in an online simulation and questionnaire involving a prototype alert for the clopidogrel and CYP2C19 drug-gene interaction. Only 4% of participants stated they would override the alert. 92% agreed that the alerts were useful. 87% found the visual interface appropriate, 91% felt the timing of the alert was appropriate and 75% were unfamiliar with the specific drug-gene interaction. 80% of providers preferred the ability to order the recommended medication within the alert. Qualitative responses suggested that supplementary information is important, but should be provided as external links, and that the utility of pharmacogenomic alerts depends on the broader ecosystem of alerts. Pharmacogenomic alerts would be welcomed by many physicians, can be built with minimalist design principles, and are appropriately placed at the end of the prescribing process. Since many physicians lack familiarity with pharmacogenomics but have limited time, information and educational resources within the alert should be carefully selected and presented in concise ways. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  15. Preventing dispensing errors by alerting for drug confusions in the pharmacy information system—A survey of users

    PubMed Central

    Campmans, Zizi; van Rhijn, Arianne; Dull, René M.; Santen-Reestman, Jacqueline; Taxis, Katja

    2018-01-01

    Introduction Drug confusion is thought to be the most common type of dispensing error. Several strategies can be implemented to reduce the risk of medication errors. One of these are alerts in the pharmacy information system. Objective To evaluate the experiences of pharmacists and pharmacy technicians with alerts for drug name and strength confusion. Methods In May 2017, a cross-sectional survey of pharmacists and pharmacy technicians was performed in community pharmacies in the Netherlands using an online questionnaire. Results Of the 269 respondents, 86% (n = 230) had noticed the alert for drug name confusion, and 26% (n = 67) for drug strength confusion. Of those 230, 9% (n = 20) had experienced that the alert had prevented dispensing the wrong drug. For drug strength confusion, this proportion was 12% (n = 8). Respondents preferred to have an alert for drug name and strength confusion in the pharmacy information system. ‘Alert fatigue’ was an important issue, so alerts should only be introduced for frequent confusions or confusions with serious consequences. Conclusion Pharmacists and pharmacy technicians were positive about having alerts for drug confusions in their pharmacy information system and experienced that alerts contributed to the prevention of dispensing errors. To prevent alert fatigue, it was considered important not to include all possible confusions as a new alert: the potential contribution to the prevention of drug confusion should be weighed against the risk of alert fatigue. PMID:29813099

  16. Primary Care Providers' Opening of Time-Sensitive Alerts Sent to Commercial Electronic Health Record InBaskets.

    PubMed

    Cutrona, Sarah L; Fouayzi, Hassan; Burns, Laura; Sadasivam, Rajani S; Mazor, Kathleen M; Gurwitz, Jerry H; Garber, Lawrence; Sundaresan, Devi; Houston, Thomas K; Field, Terry S

    2017-11-01

    Time-sensitive alerts are among the many types of clinical notifications delivered to physicians' secure InBaskets within commercial electronic health records (EHRs). A delayed alert review can impact patient safety and compromise care. To characterize factors associated with opening of non-interruptive time-sensitive alerts delivered into primary care provider (PCP) InBaskets. We analyzed data for 799 automated alerts. Alerts highlighted actionable medication concerns for older patients post-hospital discharge (2010-2011). These were study-generated alerts sent 3 days post-discharge to InBaskets for 75 PCPs across a multisite healthcare system, and represent a subset of all urgent InBasket notifications. Using EHR access and audit logs to track alert opening, we performed bivariate and multivariate analyses calculating associations between patient characteristics, provider characteristics, contextual factors at the time of alert delivery (number of InBasket notifications, weekday), and alert opening within 24 h. At the time of alert delivery, the PCPs had a median of 69 InBasket notifications and had received a median of 379.8 notifications (IQR 295.0, 492.0) over the prior 7 days. Of the 799 alerts, 47.1% were opened within 24 h. Patients with longer hospital stays (>4 days) were marginally more likely to have alerts opened (OR 1.48 [95% CI 1.00-2.19]). Alerts delivered to PCPs whose InBaskets had a higher number of notifications at the time of alert delivery were significantly less likely to be opened within 24 h (top quartile >157 notifications: OR 0.34 [95% CI 0.18-0.61]; reference bottom quartile ≤42). Alerts delivered on Saturdays were also less likely to be opened within 24 h (OR 0.18 [CI 0.08-0.39]). The number of total InBasket notifications and weekend delivery may impact the opening of time-sensitive EHR alerts. Further study is needed to support safe and effective approaches to care team management of InBasket notifications.

  17. Pilot evaluation of a method to assess prescribers' information processing of medication alerts.

    PubMed

    Russ, Alissa L; Melton, Brittany L; Daggy, Joanne K; Saleem, Jason J

    2017-02-01

    Prescribers commonly receive alerts during medication ordering. Prescribers work in a complex, time-pressured environment; to enhance the effectiveness of safety alerts, the effort needed to cognitively process these alerts should be minimized. Methods to evaluate the extent to which computerized alerts support prescribers' information processing are lacking. To develop a methodological protocol to assess the extent to which alerts support prescribers' information processing at-a-glance; specifically, the incorporation of information into their working memory. We hypothesized that the method would be feasible and that we would be able to detect a significant difference in prescribers' information processing with a revised alert display that incorporates warning design guidelines compared to the original alert display. A counterbalanced, within-subject study was conducted with 20 prescribers in a human-computer interaction laboratory. We tested a single alert that was displayed in two different ways. Prescribers were informed that an alert would appear for 10s. After the alert was shown, a white screen was displayed, and prescribers were asked to verbally describe what they saw; indicate how many total warnings; and describe anything else they remembered about the alert. We measured information processing via the accuracy of prescribers' free recall and their ability to identify that three warning messages were present. Two analysts independently evaluated participants' responses against a comprehensive catalog of alert elements and then discussed discrepancies until reaching consensus. This feasibility study demonstrated that the method seemed to be effective for evaluating prescribers' information processing of medication alert displays. With this method, we were able to detect significant differences in prescribers' recall of alert information. The proportion of total data elements that prescribers were able to accurately recall was significantly greater for the revised versus original alert display (p=0.006). With the revised display, more prescribers accurately reported that three warnings were shown (p=0.002). The methodological protocol was feasible for evaluating the alert display and yielded important findings on prescribers' information processing. Study methods supplement traditional usability evaluation methods and may be useful for evaluating information processing of other healthcare technologies. Published by Elsevier Inc.

  18. Analysis of sex differences in preadmission management of ST-segment elevation (STEMI) myocardial infarction.

    PubMed

    Greenberg, Marna Rayl; Miller, Andrew C; Mackenzie, Richard S; Richardson, David M; Ahnert, Amy M; Sclafani, Mia J; Jozefick, Jennifer L; Goyke, Terrence E; Rupp, Valerie A; Burmeister, David B

    2012-10-01

    Many reports suggest gender disparity in cardiac care as a contributor to the increased mortality among women with heart disease. We sought to identify gender differences in the management of Myocardial Infarction (MI) Alert-activated ST-segment elevation myocardial infarction (STEMI) patients that may have resulted from prehospital initiation. A retrospective database was created for MI Alert STEMI patients who presented to the emergency department (ED) of an academic community hospital with 74,000 annual visits from April 2000 through December 2008. Included were patients meeting criteria for an MI Alert (an institutional clinical practice guideline designed to expedite cardiac catheterization for STEMI patients). Data points (before and after initiation of a prehospital alert protocol) were compared and used as markers of therapy: time to ECG, receiving β-blockers, and time to the catheterization laboratory (cath lab). Differences in categorical variables by patient sex were assessed using the χ(2) test. Medians were estimated as the measure of central tendency. Quantile regression models were used to assess differences in median times between subgroups. A total of 1231 MI Alert charts were identified and analyzed. The majority of the study population were male (70%), arrived at the ED via ambulance (60.1%), and were taking a β-blocker (67.8%) or aspirin (91.6%) at the time of the ED admission. Female patients were more likely than male patients to arrive at the ED via ambulance (65.9% vs 57.6%, respectively; P = 0.014). The median age of female patients was 68 years, whereas male patients were significantly younger (median age, 59 years; P < 0.001). The proportion of patients currently taking a β-blocker or low-dose aspirin did not vary by gender. Overall, 78.2% of the MI Alert patients arriving at the ED were MI2 (alert initiated by ED physician), and this did not vary by gender (P = 0.33). A total of 1064 MI Alert patients went to the cath lab: 766 male patients (88.9%) and 298 female patients (80.8%). Overall, the median time to cath lab arrival was 79 minutes for men and 81 minutes for women (P = 0.38). Overall, the median time to cath lab arrival significantly decreased from MI1 to MI3, (P(trend) < 0.001). For prehospital-initiated alerts (MI3), the median time to cath lab arrival was the same for men and women (64 minutes; P = 1.0). For hospital-initiated alerts, time to cath lab arrival was 82 minutes for male patients and 84 minutes for female patients (P = 0.38). Prehospital activation of the process decreased the time to the cath lab by 19 minutes (P < 0.001; 95% CI, 13.2-24.8). No significant gender differences were apparent in the STEMI patients analyzed, whether the MI Alert was initiated in the ED or prehospital initiated. Initiating prehospital-based alerts significantly decreased the time to the cath lab. Copyright © 2012 Elsevier HS Journals, Inc. All rights reserved.

  19. A foundational methodology for determining system static complexity using notional lunar oxygen production processes

    NASA Astrophysics Data System (ADS)

    Long, Nicholas James

    This thesis serves to develop a preliminary foundational methodology for evaluating the static complexity of future lunar oxygen production systems when extensive information is not yet available about the various systems under consideration. Evaluating static complexity, as part of a overall system complexity analysis, is an important consideration in ultimately selecting a process to be used in a lunar base. When system complexity is higher, there is generally an overall increase in risk which could impact the safety of astronauts and the economic performance of the mission. To evaluate static complexity in lunar oxygen production, static complexity is simplified and defined into its essential components. First, three essential dimensions of static complexity are investigated, including interconnective complexity, strength of connections, and complexity in variety. Then a set of methods is developed upon which to separately evaluate each dimension. Q-connectivity analysis is proposed as a means to evaluate interconnective complexity and strength of connections. The law of requisite variety originating from cybernetic theory is suggested to interpret complexity in variety. Secondly, a means to aggregate the results of each analysis is proposed to create holistic measurement for static complexity using the Single Multi-Attribute Ranking Technique (SMART). Each method of static complexity analysis and the aggregation technique is demonstrated using notional data for four lunar oxygen production processes.

  20. Computerized Dose Range Checking Using Hard and Soft Stop Alerts Reduces Prescribing Errors in a Pediatric Intensive Care Unit.

    PubMed

    Balasuriya, Lilanthi; Vyles, David; Bakerman, Paul; Holton, Vanessa; Vaidya, Vinay; Garcia-Filion, Pamela; Westdorp, Joan; Sanchez, Christine; Kurz, Rhonda

    2017-09-01

    An enhanced dose range checking (DRC) system was developed to evaluate prescription error rates in the pediatric intensive care unit and the pediatric cardiovascular intensive care unit. An enhanced DRC system incorporating "soft" and "hard" alerts was designed and implemented. Practitioner responses to alerts for patients admitted to the pediatric intensive care unit and the pediatric cardiovascular intensive care unit were retrospectively reviewed. Alert rates increased from 0.3% to 3.4% after "go-live" (P < 0.001). Before go-live, all alerts were soft alerts. In the period after go-live, 68% of alerts were soft alerts and 32% were hard alerts. Before go-live, providers reduced doses only 1 time for every 10 dose alerts. After implementation of the enhanced computerized physician order entry system, the practitioners responded to soft alerts by reducing doses to more appropriate levels in 24.7% of orders (70/283), compared with 10% (3/30) before go-live (P = 0.0701). The practitioners deleted orders in 9.5% of cases (27/283) after implementation of the enhanced DRC system, as compared with no cancelled orders before go-live (P = 0.0774). Medication orders that triggered a soft alert were submitted unmodified in 65.7% (186/283) as compared with 90% (27/30) of orders before go-live (P = 0.0067). After go-live, 28.7% of hard alerts resulted in a reduced dose, 64% resulted in a cancelled order, and 7.4% were submitted as written. Before go-live, alerts were often clinically irrelevant. After go-live, there was a statistically significant decrease in orders that were submitted unmodified and an increase in the number of orders that were reduced or cancelled.

  1. Hemochromatosis

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  2. Bronchiectasis

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  3. Tracheostomy

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  4. Palpitations

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  5. Thalassemias

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  6. Cardioversion

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  7. 16 CFR 613.1 - Duration of active duty alerts.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 16 Commercial Practices 1 2011-01-01 2011-01-01 false Duration of active duty alerts. 613.1 Section 613.1 Commercial Practices FEDERAL TRADE COMMISSION THE FAIR CREDIT REPORTING ACT DURATION OF ACTIVE DUTY ALERTS § 613.1 Duration of active duty alerts. The duration of an active duty alert shall be...

  8. 16 CFR 613.1 - Duration of active duty alerts.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Duration of active duty alerts. 613.1 Section 613.1 Commercial Practices FEDERAL TRADE COMMISSION THE FAIR CREDIT REPORTING ACT DURATION OF ACTIVE DUTY ALERTS § 613.1 Duration of active duty alerts. The duration of an active duty alert shall be...

  9. 16 CFR 613.1 - Duration of active duty alerts.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 16 Commercial Practices 1 2012-01-01 2012-01-01 false Duration of active duty alerts. 613.1 Section 613.1 Commercial Practices FEDERAL TRADE COMMISSION THE FAIR CREDIT REPORTING ACT DURATION OF ACTIVE DUTY ALERTS § 613.1 Duration of active duty alerts. The duration of an active duty alert shall be...

  10. 47 CFR 80.277 - Ship Security Alert System (SSAS).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Ship Security Alert System (SSAS). 80.277... Security Alert System (SSAS). (a) Vessels equipped with a Ship Security Alert System pursuant to the Safety..., “RTCM Standard 11020.0—Ship Security Alert Systems (SSAS) using the Cospas-Sarsat System,” Version 1.0...

  11. Supporting secure programming in web applications through interactive static analysis.

    PubMed

    Zhu, Jun; Xie, Jing; Lipford, Heather Richter; Chu, Bill

    2014-07-01

    Many security incidents are caused by software developers' failure to adhere to secure programming practices. Static analysis tools have been used to detect software vulnerabilities. However, their wide usage by developers is limited by the special training required to write rules customized to application-specific logic. Our approach is interactive static analysis, to integrate static analysis into Integrated Development Environment (IDE) and provide in-situ secure programming support to help developers prevent vulnerabilities during code construction. No additional training is required nor are there any assumptions on ways programs are built. Our work is motivated in part by the observation that many vulnerabilities are introduced due to failure to practice secure programming by knowledgeable developers. We implemented a prototype interactive static analysis tool as a plug-in for Java in Eclipse. Our technical evaluation of our prototype detected multiple zero-day vulnerabilities in a large open source project. Our evaluations also suggest that false positives may be limited to a very small class of use cases.

  12. Supporting secure programming in web applications through interactive static analysis

    PubMed Central

    Zhu, Jun; Xie, Jing; Lipford, Heather Richter; Chu, Bill

    2013-01-01

    Many security incidents are caused by software developers’ failure to adhere to secure programming practices. Static analysis tools have been used to detect software vulnerabilities. However, their wide usage by developers is limited by the special training required to write rules customized to application-specific logic. Our approach is interactive static analysis, to integrate static analysis into Integrated Development Environment (IDE) and provide in-situ secure programming support to help developers prevent vulnerabilities during code construction. No additional training is required nor are there any assumptions on ways programs are built. Our work is motivated in part by the observation that many vulnerabilities are introduced due to failure to practice secure programming by knowledgeable developers. We implemented a prototype interactive static analysis tool as a plug-in for Java in Eclipse. Our technical evaluation of our prototype detected multiple zero-day vulnerabilities in a large open source project. Our evaluations also suggest that false positives may be limited to a very small class of use cases. PMID:25685513

  13. Lung Transplant

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  14. Carotid Endarterectomy

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  15. Pulmonary Embolism

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  16. Pernicious Anemia

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  17. Catheter Ablation

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  18. Immune Thrombocytopenia

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  19. Chest MRI

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  20. Cardiac Rehabilitation

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  1. Cardiac MRI

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  2. Oxygen Therapy

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  3. Detecting alerts, notifying the physician, and offering action items: a comprehensive alerting system.

    PubMed Central

    Kuperman, G. J.; Teich, J. M.; Bates, D. W.; Hiltz, F. L.; Hurley, J. M.; Lee, R. Y.; Paterno, M. D.

    1996-01-01

    We developed and evaluated a system to automatically identify serious clinical conditions in inpatients. The system notifies the patient's covering physician via his pager that an alert is present and offers potential therapies for the patient's condition (action items) at the time he views the alert information. Over a 6 month period, physicians responded to 1214 (70.2%) of 1730 alerts for which they were paged; they responded to 1002 (82.5% of the 1214) in less than 15 minutes. They said they would take action in 71.5% of the alerts, and they placed an order directly from the alert display screen in 39.4%. Further study is needed to determine if this alerting system improves processes or outcomes of care. PMID:8947756

  4. Revealing the functional neuroanatomy of intrinsic alertness using fMRI: methodological peculiarities.

    PubMed

    Clemens, Benjamin; Zvyagintsev, Mikhail; Sack, Alexander T; Sack, Alexander; Heinecke, Armin; Willmes, Klaus; Sturm, Walter

    2011-01-01

    Clinical observations and neuroimaging data revealed a right-hemisphere fronto-parietal-thalamic-brainstem network for intrinsic alertness, and additional left fronto-parietal activity during phasic alertness. The primary objective of this fMRI study was to map the functional neuroanatomy of intrinsic alertness as precisely as possible in healthy participants, using a novel assessment paradigm already employed in clinical settings. Both the paradigm and the experimental design were optimized to specifically assess intrinsic alertness, while at the same time controlling for sensory-motor processing. The present results suggest that the processing of intrinsic alertness is accompanied by increased activity within the brainstem, thalamus, anterior cingulate gyrus, right insula, and right parietal cortex. Additionally, we found increased activation in the left hemisphere around the middle frontal gyrus (BA 9), the insula, the supplementary motor area, and the cerebellum. Our results further suggest that rather minute aspects of the experimental design may induce aspects of phasic alertness, which in turn might lead to additional brain activation in left-frontal areas not normally involved in intrinsic alertness. Accordingly, left BA 9 activation may be related to co-activation of the phasic alertness network due to the switch between rest and task conditions functioning as an external warning cue triggering the phasic alertness network. Furthermore, activation of the intrinsic alertness network during fixation blocks due to enhanced expectancy shortly before the switch to the task block might, when subtracted from the task block, lead to diminished activation in the typical right hemisphere intrinsic alertness network. Thus, we cautiously suggest that--as a methodological artifact--left frontal activations might show up due to phasic alertness involvement and intrinsic alertness activations might be weakened due to contrasting with fixation blocks, when assessing the functional neuroanatomy of intrinsic alertness with a block design in fMRI studies.

  5. Revealing the Functional Neuroanatomy of Intrinsic Alertness Using fMRI: Methodological Peculiarities

    PubMed Central

    Clemens, Benjamin; Zvyagintsev, Mikhail; Sack, Alexander; Heinecke, Armin; Willmes, Klaus; Sturm, Walter

    2011-01-01

    Clinical observations and neuroimaging data revealed a right-hemisphere fronto-parietal-thalamic-brainstem network for intrinsic alertness, and additional left fronto-parietal activity during phasic alertness. The primary objective of this fMRI study was to map the functional neuroanatomy of intrinsic alertness as precisely as possible in healthy participants, using a novel assessment paradigm already employed in clinical settings. Both the paradigm and the experimental design were optimized to specifically assess intrinsic alertness, while at the same time controlling for sensory-motor processing. The present results suggest that the processing of intrinsic alertness is accompanied by increased activity within the brainstem, thalamus, anterior cingulate gyrus, right insula, and right parietal cortex. Additionally, we found increased activation in the left hemisphere around the middle frontal gyrus (BA 9), the insula, the supplementary motor area, and the cerebellum. Our results further suggest that rather minute aspects of the experimental design may induce aspects of phasic alertness, which in turn might lead to additional brain activation in left-frontal areas not normally involved in intrinsic alertness. Accordingly, left BA 9 activation may be related to co-activation of the phasic alertness network due to the switch between rest and task conditions functioning as an external warning cue triggering the phasic alertness network. Furthermore, activation of the intrinsic alertness network during fixation blocks due to enhanced expectancy shortly before the switch to the task block might, when subtracted from the task block, lead to diminished activation in the typical right hemisphere intrinsic alertness network. Thus, we cautiously suggest that – as a methodological artifact – left frontal activations might show up due to phasic alertness involvement and intrinsic alertness activations might be weakened due to contrasting with fixation blocks, when assessing the functional neuroanatomy of intrinsic alertness with a block design in fMRI studies. PMID:21984928

  6. ToxAlerts: a Web server of structural alerts for toxic chemicals and compounds with potential adverse reactions.

    PubMed

    Sushko, Iurii; Salmina, Elena; Potemkin, Vladimir A; Poda, Gennadiy; Tetko, Igor V

    2012-08-27

    The article presents a Web-based platform for collecting and storing toxicological structural alerts from literature and for virtual screening of chemical libraries to flag potentially toxic chemicals and compounds that can cause adverse side effects. An alert is uniquely identified by a SMARTS template, a toxicological endpoint, and a publication where the alert was described. Additionally, the system allows storing complementary information such as name, comments, and mechanism of action, as well as other data. Most importantly, the platform can be easily used for fast virtual screening of large chemical datasets, focused libraries, or newly designed compounds against the toxicological alerts, providing a detailed profile of the chemicals grouped by structural alerts and endpoints. Such a facility can be used for decision making regarding whether a compound should be tested experimentally, validated with available QSAR models, or eliminated from consideration altogether. The alert-based screening can also be helpful for an easier interpretation of more complex QSAR models. The system is publicly accessible and tightly integrated with the Online Chemical Modeling Environment (OCHEM, http://ochem.eu). The system is open and expandable: any registered OCHEM user can introduce new alerts, browse, edit alerts introduced by other users, and virtually screen his/her data sets against all or selected alerts. The user sets being passed through the structural alerts can be used at OCHEM for other typical tasks: exporting in a wide variety of formats, development of QSAR models, additional filtering by other criteria, etc. The database already contains almost 600 structural alerts for such endpoints as mutagenicity, carcinogenicity, skin sensitization, compounds that undergo metabolic activation, and compounds that form reactive metabolites and, thus, can cause adverse reactions. The ToxAlerts platform is accessible on the Web at http://ochem.eu/alerts, and it is constantly growing.

  7. ToxAlerts: A Web Server of Structural Alerts for Toxic Chemicals and Compounds with Potential Adverse Reactions

    PubMed Central

    2012-01-01

    The article presents a Web-based platform for collecting and storing toxicological structural alerts from literature and for virtual screening of chemical libraries to flag potentially toxic chemicals and compounds that can cause adverse side effects. An alert is uniquely identified by a SMARTS template, a toxicological endpoint, and a publication where the alert was described. Additionally, the system allows storing complementary information such as name, comments, and mechanism of action, as well as other data. Most importantly, the platform can be easily used for fast virtual screening of large chemical datasets, focused libraries, or newly designed compounds against the toxicological alerts, providing a detailed profile of the chemicals grouped by structural alerts and endpoints. Such a facility can be used for decision making regarding whether a compound should be tested experimentally, validated with available QSAR models, or eliminated from consideration altogether. The alert-based screening can also be helpful for an easier interpretation of more complex QSAR models. The system is publicly accessible and tightly integrated with the Online Chemical Modeling Environment (OCHEM, http://ochem.eu). The system is open and expandable: any registered OCHEM user can introduce new alerts, browse, edit alerts introduced by other users, and virtually screen his/her data sets against all or selected alerts. The user sets being passed through the structural alerts can be used at OCHEM for other typical tasks: exporting in a wide variety of formats, development of QSAR models, additional filtering by other criteria, etc. The database already contains almost 600 structural alerts for such endpoints as mutagenicity, carcinogenicity, skin sensitization, compounds that undergo metabolic activation, and compounds that form reactive metabolites and, thus, can cause adverse reactions. The ToxAlerts platform is accessible on the Web at http://ochem.eu/alerts, and it is constantly growing. PMID:22876798

  8. Alert status of nuclear weapons

    NASA Astrophysics Data System (ADS)

    Kristensen, Hans M.

    2017-11-01

    Nuclear Alert Forces. Four nuclear-armed states deploy nuclear warheads on alert, ready to be used on relatively short notice: United States, Russia, France and Britain. Combined, the four countries deploy an estimated 1,869 nuclear alert warheads. Russia and the United States deploy 1,749 alert warheads combined, or 94% of all alert warheads. Despite some debate about possible need to increase readiness of nuclear forces (China, Pakistan), the five other nuclear-armed states (China, Pakistan, India, Israel and North Korea) are thought to store their warheads separate from launchers under normal circumstances. The overall number of alert warheads has remained relatively stable during the past five years.

  9. Geo-targeted Weather Alerts Coming to Millions of Mobile Devices

    NASA Astrophysics Data System (ADS)

    Gerber, M.

    2011-12-01

    The Personal Localized Alert Network (PLAN), aka Commercial Mobile Alert System (CMAS), is readying for roll out and will be broadcasting emergency public alerts to millions of cell phones by the middle of 2012. Learn how the National Weather Serivce (NWS) is supplying PLAN with geo-referenced weather alert information in the industry standard Common Alerting Protocol (CAP) format and how you can access this same information for integration with mobile devices, other consumer electronics, and decision support systems. Information will also be provided on the NWS' new collaborative venue that encourages wide participation in the evolution and use of NWS CAP alerts in a variety of applications.

  10. Automated External Defibrillator

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  11. Thrombocythemia and Thrombocytosis

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  12. von Willebrand Disease

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  13. Chest X-Ray

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  14. What Is Cardiomyopathy?

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  15. Long QT Syndrome

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  16. Percutaneous Coronary Intervention

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  17. What is Hemophilia?

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  18. Thrombotic Thrombocytopenic Purpura

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  19. What Is Anemia?

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  20. Cardiac CT Scan

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  1. Coronary Calcium Scan

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  2. Patent Ductus Arteriosus

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  3. What is Bronchoscopy?

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  4. AGILE/GRID Science Alert Monitoring System: The Workflow and the Crab Flare Case

    NASA Astrophysics Data System (ADS)

    Bulgarelli, A.; Trifoglio, M.; Gianotti, F.; Tavani, M.; Conforti, V.; Parmiggiani, N.

    2013-10-01

    During the first five years of the AGILE mission we have observed many gamma-ray transients of Galactic and extragalactic origin. A fast reaction to unexpected transient events is a crucial part of the AGILE monitoring program, because the follow-up of astrophysical transients is a key point for this space mission. We present the workflow and the software developed by the AGILE Team to perform the automatic analysis for the detection of gamma-ray transients. In addition, an App for iPhone will be released enabling the Team to access the monitoring system through mobile phones. In 2010 September the science alert monitoring system presented in this paper recorded a transient phenomena from the Crab Nebula, generating an automated alert sent via email and SMS two hours after the end of an AGILE satellite orbit, i.e. two hours after the Crab flare itself: for this discovery AGILE won the 2012 Bruno Rossi prize. The design of this alert system is maximized to reach the maximum speed, and in this, as in many other cases, AGILE has demonstrated that the reaction speed of the monitoring system is crucial for the scientific return of the mission.

  5. The First Ground-Level Enhancement of Solar Cycle 24 on 17 May 2012 and Its Real-Time Detection

    NASA Astrophysics Data System (ADS)

    Papaioannou, A.; Souvatzoglou, G.; Paschalis, P.; Gerontidou, M.; Mavromichalaki, H.

    2014-01-01

    Ground-level enhancements (GLEs) are defined as sudden increases in the recorded intensity of cosmic-ray particles, usually by neutron monitors (NMs). In this work we present a time-shifting analysis (TSA) for the first arriving particles that were detected at Earth by NMs. We also present an automated real-time GLE alert that has been developed and is operating via the Neutron Monitor Database (NMDB), which successfully identified the 17 May 2012 event, designated as GLE71. We discuss the time evolution of the real-time GLE alert that was issued for GLE71 and present the event onset-time for NMs that contributed to this GLE alert based on their archived data. A comparison with their real-time time-stamp was made to illustrate the necessity for high-resolution data ( e.g. 1-min time resolution) made available at every minute. The first results on the propagation of relativistic protons that have been recorded by NMs, as inferred by the TSA, imply that they are most probably accelerated by the coronal-mass-ejection-driven shock. Furthermore, the successful usage of NM data and the corresponding achievement of issuing a timely GLE alert are discussed.

  6. Alertness and cognitive control: Testing the early onset hypothesis.

    PubMed

    Schneider, Darryl W

    2018-05-01

    Previous research has revealed a peculiar interaction between alertness and cognitive control in selective-attention tasks: Congruency effects are larger on alert trials (on which an alerting cue is presented briefly in advance of the imperative stimulus) than on no-alert trials, despite shorter response times (RTs) on alert trials. One explanation for this finding is the early onset hypothesis, which is based on the assumptions that increased alertness shortens stimulus-encoding time and that cognitive control involves gradually focusing attention during a trial. The author tested the hypothesis in 3 experiments by manipulating alertness and stimulus quality (which were intended to shorten and lengthen stimulus-encoding time, respectively) in an arrow-based flanker task involving congruent and incongruent stimuli. Replicating past findings, the alerting manipulation led to shorter RTs but larger congruency effects on alert trials than on no-alert trials. The stimulus-quality manipulation led to longer RTs and larger congruency effects for degraded stimuli than for intact stimuli. These results provide mixed support for the early onset hypothesis, but the author discusses how data and theory might be reconciled if stimulus quality affects stimulus-encoding time and the rate of evidence accumulation in the decision process. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  7. Holter and Event Monitors

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  8. CHEMICAL SAFETY ALERTS-

    EPA Science Inventory

    Chemical Safety Alerts are short publications which explain specific hazards that have become evident through chemical accident investigation efforts. EPA has produced over a dozen Alerts to date. This year's Alert: Managing Chemical Reactivity Hazards

  9. What Is Heart Failure?

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  10. What Is Bronchopulmonary Dysplasia?

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  11. What Is Cardiac Catheterization?

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  12. What Is a Ventilator?

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  13. What Are Sleep Studies?

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  14. What Are the Lungs?

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  15. Aircraft Alerting Systems Criteria Study. Volume 1. Collation and Analysis of Aircraft Alerting Systems Data

    DTIC Science & Technology

    1977-05-01

    light, or flag. The term .gI4er includes the situation wheroin a pointer or tape on an analog Indicator displays a parameter value in the green, yellow...or flap. Only the parameter limit information (bands) on the instruments was considered to have a significant impact on the visual effectiveness of the...the time it takes the obse.-ver to react to the signal ( reactive time) when that was the only task that he had to do. The quantitative applicobility

  16. What Is Sudden Cardiac Arrest?

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  17. Blood and Bone Marrow Transplant?

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  18. What Is Respiratory Distress Syndrome?

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  19. What Is a Heart Transplant?

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  20. What is Broken Heart Syndrome

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  1. ARDS (Acute Respiratory Distress Syndrome)

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  2. What Are Bone Marrow Tests?

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  3. Auditory alert systems with enhanced detectability

    NASA Technical Reports Server (NTRS)

    Begault, Durand R. (Inventor)

    2008-01-01

    Methods and systems for distinguishing an auditory alert signal from a background of one or more non-alert signals. In a first embodiment, a prefix signal, associated with an existing alert signal, is provided that has a signal component in each of three or more selected frequency ranges, with each signal component in each of three or more selected level at least 3-10 dB above an estimated background (non-alert) level in that frequency range. The alert signal may be chirped within one or more frequency bands. In another embodiment, an alert signal moves, continuously or discontinuously, from one location to another over a short time interval, introducing a perceived spatial modulation or jitter. In another embodiment, a weighted sum of background signals adjacent to each ear is formed, and the weighted sum is delivered to each ear as a uniform background; a distinguishable alert signal is presented on top of this weighted sum signal at one ear, or distinguishable first and second alert signals are presented at two ears of a subject.

  4. Next Generation Monitoring: Tier 2 Experience

    NASA Astrophysics Data System (ADS)

    Fay, R.; Bland, J.; Jones, S.

    2017-10-01

    Monitoring IT infrastructure is essential for maximizing availability and minimizing disruption by detecting failures and developing issues. The HEP group at Liverpool have recently updated our monitoring infrastructure with the goal of increasing coverage, improving visualization capabilities, and streamlining configuration and maintenance. Here we present a summary of Liverpool’s experience, the monitoring infrastructure, and the tools used to build it. In brief, system checks are configured in Puppet using Hiera, and managed by Sensu, replacing Nagios. Centralised logging is managed with Elasticsearch, together with Logstash and Filebeat. Kibana provides an interface for interactive analysis, including visualization and dashboards. Metric collection is also configured in Puppet, managed by collectd and stored in Graphite, with Grafana providing a visualization and dashboard tool. The Uchiwa dashboard for Sensu provides a web interface for viewing infrastructure status. Alert capabilities are provided via external handlers. A custom alert handler is in development to provide an easily configurable, extensible and maintainable alert facility.

  5. Visual perception affected by motivation and alertness controlled by a noninvasive brain-computer interface

    PubMed Central

    Zhuravlev, Maksim O.; Makarov, Vladimir V.; Nedayvozov, Vladimir; Grubov, Vadim V.; Pchelintceva, Svetlana V.; Hramov, Alexander E.

    2017-01-01

    The influence of motivation and alertness on brain activity associated with visual perception was studied experimentally using the Necker cube, which ambiguity was controlled by the contrast of its ribs. The wavelet analysis of recorded multichannel electroencephalograms (EEG) allowed us to distinguish two different scenarios while the brain processed the ambiguous stimulus. The first scenario is characterized by a particular destruction of alpha rhythm (8–12 Hz) with a simultaneous increase in beta-wave activity (20–30 Hz), whereas in the second scenario, the beta rhythm is not well pronounced while the alpha-wave energy remains unchanged. The experiments were carried out with a group of financially motivated subjects and another group of unpaid volunteers. It was found that the first scenario occurred mainly in the motivated group. This can be explained by the increased alertness of the motivated subjects. The prevalence of the first scenario was also observed in a group of subjects to whom images with higher ambiguity were presented. We believe that the revealed scenarios can occur not only during the perception of bistable images, but also in other perceptual tasks requiring decision making. The obtained results may have important applications for monitoring and controlling human alertness in situations which need substantial attention. On the base of the obtained results we built a brain-computer interface to estimate and control the degree of alertness in real time. PMID:29267295

  6. 47 CFR 10.300 - Alert aggregator. [Reserved

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 1 2013-10-01 2013-10-01 false Alert aggregator. [Reserved] 10.300 Section 10.300 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.300 Alert aggregator. [Reserved] ...

  7. 47 CFR 10.300 - Alert aggregator. [Reserved

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 1 2014-10-01 2014-10-01 false Alert aggregator. [Reserved] 10.300 Section 10.300 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.300 Alert aggregator. [Reserved] ...

  8. 49 CFR 229.140 - Alerters.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... alerters shall provide an audio alarm upon expiration of the timing cycle interval. An alerter on a... indication to the operator at least five seconds prior to an audio alarm. The visual indication on an alerter...

  9. What Is a Total Artificial Heart?

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  10. What Is a Ventricular Assist Device?

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  11. Development and implementation of sepsis alert systems

    PubMed Central

    Harrison, Andrew M.; Gajic, Ognjen; Pickering, Brian W.; Herasevich, Vitaly

    2016-01-01

    Synopsis/Summary Development and implementation of sepsis alert systems is challenging, particularly outside the monitored intensive care unit (ICU) setting. Important barriers to wider use of sepsis alerts include evolving clinical definitions of sepsis, information overload & alert fatigue, due to suboptimal alert performance. Outside the ICU, additional barriers include differences in health care delivery models, charting behaviors, and availability of electronic data. Currently available evidence does not support routine use of sepsis alert systems in clinical practice. However, continuous improvement in both the afferent (data availability and accuracy of detection algorithms) and efferent (evidence-based decision support and smoother integration into clinical workflow) limbs of sepsis alert systems will help translate theoretical advantages into measurable patient benefit. PMID:27229639

  12. Wireless clinical alerts for physiologic, laboratory and medication data.

    PubMed Central

    Shabot, M. M.; LoBue, M.; Chen, J.

    2000-01-01

    A fully interfaced clinical information system (CIS) contains physiologic, laboratory, blood gas, medication and other data that can be used as the information base for a comprehensive alerting system. Coupled with an event driven rules engine, a CIS can generate clinical alerts which may both prevent medical errors and assist caregivers in responding to critical events in a timely way. The authors have developed a clinical alerting system which delivers alerts and reminders to clinicians in real time via a alphanumeric display pagers. This paper will describe the system, the type and number of alerts generated, and the impact on clinical practice. A major issue remains in measuring the impact of wireless alerts on patient outcomes. PMID:11079992

  13. Alerts in mobile healthcare applications: requirements and pilot study.

    PubMed

    Kafeza, Eleanna; Chiu, Dickson K W; Cheung, S C; Kafeza, Marina

    2004-06-01

    Recent advances in mobile technologies have greatly extended traditional communication technologies to mobile devices. At the same time, healthcare environments are by nature "mobile" where doctors and nurses do not have fixed workspaces. Irregular and exceptional events are generated in daily hospital routines, such as operations rescheduling, laboratory/examination results, and adverse drug events. These events may create requests that should be delivered to the appropriate person at the appropriate time. Those requests that are classified as urgent are referred to as alerts. Efficient routing and monitoring of alerts are keys to quality and cost-effective healthcare services. Presently, these are generally handled in an ad hoc manner. In this paper, we propose the use of a healthcare alert management system to handle these alert messages systematically. We develop a model for specifying alerts that are associated with medical tasks and a set of parameters for their routing. We design an alert monitor that matches medical staff and their mobile devices to receive alerts, based on the requirements of these alerts. We also propose a mechanism to handle and reroute, if necessary, an alert message when it has not been acknowledged within a specific deadline.

  14. Closing the Loop in ICU Decision Support: Physiologic Event Detection, Alerts, and Documentation

    PubMed Central

    Norris, Patrick R.; Dawant, Benoit M.

    2002-01-01

    Automated physiologic event detection and alerting is a challenging task in the ICU. Ideally care providers should be alerted only when events are clinically significant and there is opportunity for corrective action. However, the concepts of clinical significance and opportunity are difficult to define in automated systems, and effectiveness of alerting algorithms is difficult to measure. This paper describes recent efforts on the Simon project to capture information from ICU care providers about patient state and therapy in response to alerts, in order to assess the value of event definitions and progressively refine alerting algorithms. Event definitions for intracranial pressure and cerebral perfusion pressure were studied by implementing a reliable system to automatically deliver alerts to clinical users’ alphanumeric pagers, and to capture associated documentation about patient state and therapy when the alerts occurred. During a 6-month test period in the trauma ICU at Vanderbilt University Medical Center, 530 alerts were detected in 2280 hours of data spanning 14 patients. Clinical users electronically documented 81% of these alerts as they occurred. Retrospectively classifying documentation based on therapeutic actions taken, or reasons why actions were not taken, provided useful information about ways to potentially improve event definitions and enhance system utility.

  15. Reliability of Trained Dogs to Alert to Hypoglycemia in Patients With Type 1 Diabetes

    PubMed Central

    Los, Evan A.; Ramsey, Katrina L.; Guttmann-Bauman, Ines; Ahmann, Andrew J.

    2016-01-01

    Background: We examined the reliability of trained dogs to alert to hypoglycemia in individuals with type 1 diabetes. Methods: Patients with type 1 diabetes who currently used diabetes alert dogs participated in this exploratory study. Subjects reported satisfaction, perceived dog glucose sensing ability and reasons for obtaining a trained dog. Reliability of dog alerts was assessed using capillary blood glucose (CBG) and blinded continuous glucose monitoring (CGM) as comparators in 8 subjects (age 4-48). Hypoglycemia was defined as CBG or CGM <70 mg/dL. Results: Dog users were very satisfied (8.9/10 on a Likert-type scale) and largely confident (7.9/10) in their dog’s ability to detect hypoglycemia. Detection of hypoglycemia was the primary reason for obtaining a trained dog. During hypoglycemia, spontaneous dog alerts occurred at a rate 3.2 (2.0-5.2, 95% CI) times higher than during euglycemia (70-179 mg/dL). Dogs provided timely alerts in 36% (sensitivity) of all hypoglycemia events (n = 45). Due to inappropriate alerts, the PPV of a dog alert for hypoglycemia was 12%. When there was concurrence of a hypoglycemic event between the dog alert and CGM (n = 30), CGM would have alerted prior to the dog in 73% of events (median 22-minute difference). Conclusions: This is the first study evaluating reliability of trained dogs to alert to hypoglycemia under real-life conditions. Trained dogs often alert a human companion to otherwise unknown hypoglycemia; however due to high false-positive rate, a dog alert alone is unlikely to be helpful in differentiating hypo-/hyper-/euglycemia. CGM often detects hypoglycemia before a trained dog by a clinically significant margin. PMID:27573791

  16. Reliability of Trained Dogs to Alert to Hypoglycemia in Patients With Type 1 Diabetes.

    PubMed

    Los, Evan A; Ramsey, Katrina L; Guttmann-Bauman, Ines; Ahmann, Andrew J

    2017-05-01

    We examined the reliability of trained dogs to alert to hypoglycemia in individuals with type 1 diabetes. Patients with type 1 diabetes who currently used diabetes alert dogs participated in this exploratory study. Subjects reported satisfaction, perceived dog glucose sensing ability and reasons for obtaining a trained dog. Reliability of dog alerts was assessed using capillary blood glucose (CBG) and blinded continuous glucose monitoring (CGM) as comparators in 8 subjects (age 4-48). Hypoglycemia was defined as CBG or CGM <70 mg/dL. Dog users were very satisfied (8.9/10 on a Likert-type scale) and largely confident (7.9/10) in their dog's ability to detect hypoglycemia. Detection of hypoglycemia was the primary reason for obtaining a trained dog. During hypoglycemia, spontaneous dog alerts occurred at a rate 3.2 (2.0-5.2, 95% CI) times higher than during euglycemia (70-179 mg/dL). Dogs provided timely alerts in 36% (sensitivity) of all hypoglycemia events (n = 45). Due to inappropriate alerts, the PPV of a dog alert for hypoglycemia was 12%. When there was concurrence of a hypoglycemic event between the dog alert and CGM (n = 30), CGM would have alerted prior to the dog in 73% of events (median 22-minute difference). This is the first study evaluating reliability of trained dogs to alert to hypoglycemia under real-life conditions. Trained dogs often alert a human companion to otherwise unknown hypoglycemia; however due to high false-positive rate, a dog alert alone is unlikely to be helpful in differentiating hypo-/hyper-/euglycemia. CGM often detects hypoglycemia before a trained dog by a clinically significant margin.

  17. 47 CFR 10.300 - Alert aggregator. [Reserved

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Alert aggregator. [Reserved] 10.300 Section 10.300 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.300 Alert aggregator. [Reserved] ...

  18. 47 CFR 10.300 - Alert aggregator. [Reserved

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 1 2012-10-01 2012-10-01 false Alert aggregator. [Reserved] 10.300 Section 10.300 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.300 Alert aggregator. [Reserved] ...

  19. 47 CFR 10.300 - Alert aggregator. [Reserved

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 1 2011-10-01 2011-10-01 false Alert aggregator. [Reserved] 10.300 Section 10.300 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.300 Alert aggregator. [Reserved] ...

  20. Aspirin to Prevent a First Heart Attack or Stroke

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  1. An easily implemented static condensation method for structural sensitivity analysis

    NASA Technical Reports Server (NTRS)

    Gangadharan, S. N.; Haftka, R. T.; Nikolaidis, E.

    1990-01-01

    A black-box approach to static condensation for sensitivity analysis is presented with illustrative examples of a cube and a car structure. The sensitivity of the structural response with respect to joint stiffness parameter is calculated using the direct method, forward-difference, and central-difference schemes. The efficiency of the various methods for identifying joint stiffness parameters from measured static deflections of these structures is compared. The results indicate that the use of static condensation can reduce computation times significantly and the black-box approach is only slightly less efficient than the standard implementation of static condensation. The ease of implementation of the black-box approach recommends it for use with general-purpose finite element codes that do not have a built-in facility for static condensation.

  2. Pilot Non-Conformance to Alerting System Commands During Closely Spaced Parallel Approaches

    NASA Technical Reports Server (NTRS)

    Pritchett, Amy Ruth; Hansman, R. John; Corker, Kevin (Technical Monitor)

    1997-01-01

    Cockpit alerting systems monitor potentially hazardous situations, both inside and outside the aircraft. When a hazard is projected to occur, the alerting system displays alerts and/or command decisions to the pilot. However, pilots have been observed to not conform to alerting system commands by delaying their response or by not following the automatic commands exactly. This non-conformance to the automatic alerting system can reduce its benefit. Therefore, a need exists to understand the causes and effects of pilot non-conformance in order to develop automatic alerting systems whose commands the pilots are more likely to follow. These considerations were examined through flight simulator evaluations of the collision avoidance task during closely spaced parallel approaches. This task provided a useful case-study because the effects of non-conformance can be significant, given the time-critical nature of the task. A preliminary evaluation of alerting systems identified non-conformance in over 40% of the cases and a corresponding drop in collision avoidance performance. A follow-on experiment found subjects' alerting and maneuver selection criteria were consistent with different strategies than those used by automatic systems, indicating the pilot may potentially disagree with the alerting system if the pilot attempts to verify automatic alerts and commanded avoidance maneuvers. A final experiment found supporting automatic alerts with the explicit display of its underlying criteria resulted in more consistent subject reactions. In light of these experimental results, a general discussion of pilot non-conformance is provided. Contributing factors in pilot non-conformance include a lack of confidence in the automatic system and mismatches between the alerting system's commands and the pilots' own decisions based on the information available to them. The effects of non-conformance on system performance are discussed. Possible methods of reconciling mismatches are given, and design considerations for alerting systems which alleviate the problem of non-conformance are provided.

  3. Validation of a personal fluid loss monitor.

    PubMed

    Wickwire, J; Bishop, P A; Green, J M; Richardson, M T; Lomax, R G; Casaru, C; Jones, E; Curtner-Smith, M

    2008-02-01

    Dehydration raises heat injury risk and reduces performance [ , , ]. The purpose was to validate the Hydra-Alert Jr (Acumen). The Hydra-Alert was tested in two exercise/clothing conditions. Participants wore it while wearing exercise clothing and exercising at a self-selected intensity (n = 8). Others wore the Hydra-Alert while wearing a ballistic-vest and performing an industrial-protocol (n = 8). For each condition, the Hydra-Alert was tested on two occasions (T1 and T2). The Hydra-Alert was tested against nude weight loss for both conditions. The Hydra-Alert had low test-retest reliability for both conditions (average absolute value of the error between Hydra-Alert outputs of T1 and T2 = 0.08 +/- 0.08 percentage points). With exercise-clothing, the Hydra-Alert evidenced low-moderate correlations between percent nude weight loss and Hydra-Alert output at 20 min (r = 0.59-T1, p = 0.13; r = 0.12-T2, p = 0.78), at 40 min (r = 0.93-T1, p = 0.001; r = 0.63-T2, p = 0.10), and at approximately 2 % weight loss (r = 0.21-T1 and T2, p = 0.61 and 0.62, respectively). The correlation at 40 min during T1 fell during T2 suggesting the Hydra-Alert was inconsistent. When wearing a ballistic-vest, the Hydra-Alert had poor validity (T1: r = - 0.29 [p = 0.48] for weight loss vs. monitor; T2: r = 0.11 [p = 0.80]). At the higher levels of dehydration ( approximately 2 %), the Hydra-Alert error was so high as to render its readings of little value. In some cases, the Hydra-Alert could lead to a false level of security if dehydrated. Therefore, the Hydra-Alert is of little use for those who want to measure their fluid loss while exercising in the heat.

  4. Real-time data acquisition and alerts may reduce reaction time and improve perfusionist performance during cardiopulmonary bypass.

    PubMed

    Beck, J R; Fung, K; Lopez, H; Mongero, L B; Argenziano, M

    2015-01-01

    Delayed perfusionist identification and reaction to abnormal clinical situations has been reported to contribute to increased mortality and morbidity. The use of automated data acquisition and compliance safety alerts has been widely accepted in many industries and its use may improve operator performance. A study was conducted to evaluate the reaction time of perfusionists with and without the use of compliance alert. A compliance alert is a computer-generated pop-up banner on a pump-mounted computer screen to notify the user of clinical parameters outside of a predetermined range. A proctor monitored and recorded the time from an alert until the perfusionist recognized the parameter was outside the desired range. Group one included 10 cases utilizing compliance alerts. Group 2 included 10 cases with the primary perfusionist blinded to the compliance alerts. In Group 1, 97 compliance alerts were identified and, in group two, 86 alerts were identified. The average reaction time in the group using compliance alerts was 3.6 seconds. The average reaction time in the group not using the alerts was nearly ten times longer than the group using computer-assisted, real-time data feedback. Some believe that real-time computer data acquisition and feedback improves perfusionist performance and may allow clinicians to identify and rectify potentially dangerous situations. © The Author(s) 2014.

  5. Nursing, Pharmacy, and Prescriber Knowledge and Perceptions of High-Alert Medications in a Large, Academic Medical Hospital

    PubMed Central

    Engels, Melanie J.

    2015-01-01

    Background: High-alert medications pose a greater risk of causing significant harm to patients if used in error. The Joint Commission requires that hospitals define institution-specific high-alert medications and implement processes to ensure safe medication use. Method: Nursing, pharmacy, and prescribers were asked to voluntarily complete a 34-question survey to assess their knowledge, experience, and perceptions regarding high-alert medications in an academic hospital. Results: The majority of respondents identified the organization’s high-alert medications, the consequences of an error involving a high-alert medication, and the reversal agent. Most of the risk-reduction strategies within the institution were viewed as being effective by respondents. Forty-five percent of the respondents utilized a high-alert medication in the previous 24 hours. Only 14.2% had experienced an error with a high-alert medication in the previous 12 months, with 46% being near misses. The survey found the 5 rights for medication administration were not being utilized consistently. Respondents indicated that work experience or hospital orientation is the preferred learning experience for high-alert medications. Conclusions: This study assessed all disciplines involved in the medication use process. Perceptions about high-alert medications differ between disciplines. Ongoing discipline-specific education is required to ensure that individuals accept accountability in the medication use process and to close knowledge gaps on high-alert medications and risk-reduction strategies. PMID:26446747

  6. 47 CFR 10.310 - Federal alert gateway. [Reserved

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Federal alert gateway. [Reserved] 10.310 Section 10.310 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.310 Federal alert gateway. [Reserved] ...

  7. 47 CFR 10.310 - Federal alert gateway. [Reserved

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 1 2013-10-01 2013-10-01 false Federal alert gateway. [Reserved] 10.310 Section 10.310 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.310 Federal alert gateway. [Reserved] ...

  8. 47 CFR 10.310 - Federal alert gateway. [Reserved

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 1 2014-10-01 2014-10-01 false Federal alert gateway. [Reserved] 10.310 Section 10.310 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.310 Federal alert gateway. [Reserved] ...

  9. 47 CFR 10.310 - Federal alert gateway. [Reserved

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 1 2012-10-01 2012-10-01 false Federal alert gateway. [Reserved] 10.310 Section 10.310 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.310 Federal alert gateway. [Reserved] ...

  10. 47 CFR 10.310 - Federal alert gateway. [Reserved

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 1 2011-10-01 2011-10-01 false Federal alert gateway. [Reserved] 10.310 Section 10.310 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.310 Federal alert gateway. [Reserved] ...

  11. AmberAlert / DPS / DHSEM / AAB

    Science.gov Websites

    cooperative public service alert to aid in the safe recovery of abducted children. The Alaska AMBER Alert children to aid in their safe return. AMBER Alert Hotline: 866-AKAMBER - (866-252-6237) State of Alaska

  12. A review of human factors principles for the design and implementation of medication safety alerts in clinical information systems.

    PubMed

    Phansalkar, Shobha; Edworthy, Judy; Hellier, Elizabeth; Seger, Diane L; Schedlbauer, Angela; Avery, Anthony J; Bates, David W

    2010-01-01

    The objective of this review is to describe the implementation of human factors principles for the design of alerts in clinical information systems. First, we conduct a review of alarm systems to identify human factors principles that are employed in the design and implementation of alerts. Second, we review the medical informatics literature to provide examples of the implementation of human factors principles in current clinical information systems using alerts to provide medication decision support. Last, we suggest actionable recommendations for delivering effective clinical decision support using alerts. A review of studies from the medical informatics literature suggests that many basic human factors principles are not followed, possibly contributing to the lack of acceptance of alerts in clinical information systems. We evaluate the limitations of current alerting philosophies and provide recommendations for improving acceptance of alerts by incorporating human factors principles in their design.

  13. Subjective assessment of usefulness and appropriate presentation mode of alerts and reminders in the outpatient setting.

    PubMed Central

    Krall, M. A.; Sittig, D. F.

    2001-01-01

    There is very little known about the limits of alerting in the setting of the outpatient Electronic Medical Record (EMR). We are interested in how users value and prefer such alerts. One hundred Kaiser Permanente primary care clinicians were sent a four-page questionnaire. It contained questions related to the usability and usefulness of different approaches to presenting reminder and alert information. The survey also contained questions about the desirability of six categories of alerts. Forty-three of 100 questionnaires were returned. Users generally preferred an active, more intrusive interaction model for "alerts" and a passive, less intrusive model for order messages and other types of reminders and notifications. Drug related alerts were more highly rated than health maintenance or disease state reminders. Users indicated that more alerts would make the system "more useful" but "less easy to use". PMID:11825206

  14. Alerts Visualization and Clustering in Network-based Intrusion Detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Dr. Li; Gasior, Wade C; Dasireddy, Swetha

    2010-04-01

    Today's Intrusion detection systems when deployed on a busy network overload the network with huge number of alerts. This behavior of producing too much raw information makes it less effective. We propose a system which takes both raw data and Snort alerts to visualize and analyze possible intrusions in a network. Then we present with two models for the visualization of clustered alerts. Our first model gives the network administrator with the logical topology of the network and detailed information of each node that involves its associated alerts and connections. In the second model, flocking model, presents the network administratormore » with the visual representation of IDS data in which each alert is represented in different color and the alerts with maximum similarity move together. This gives network administrator with the idea of detecting various of intrusions through visualizing the alert patterns.« less

  15. Subjective assessment of usefulness and appropriate presentation mode of alerts and reminders in the outpatient setting.

    PubMed

    Krall, M A; Sittig, D F

    2001-01-01

    There is very little known about the limits of alerting in the setting of the outpatient Electronic Medical Record (EMR). We are interested in how users value and prefer such alerts. One hundred Kaiser Permanente primary care clinicians were sent a four-page questionnaire. It contained questions related to the usability and usefulness of different approaches to presenting reminder and alert information. The survey also contained questions about the desirability of six categories of alerts. Forty-three of 100 questionnaires were returned. Users generally preferred an active, more intrusive interaction model for "alerts" and a passive, less intrusive model for order messages and other types of reminders and notifications. Drug related alerts were more highly rated than health maintenance or disease state reminders. Users indicated that more alerts would make the system "more useful" but "less easy to use".

  16. The influence of essential oils on human attention. I: alertness.

    PubMed

    Ilmberger, J; Heuberger, E; Mahrhofer, C; Dessovic, H; Kowarik, D; Buchbauer, G

    2001-03-01

    Scientific research on the effects of essential oils on human behavior lags behind the promises made by popular aromatherapy. Nearly all aspects of human behavior are closely linked to processes of attention, the basic level being that of alertness, which ranges from sleep to wakefulness. In our study we measured the influence of essential oils and components of essential oils [peppermint, jasmine, ylang-ylang, 1,8-cineole (in two different dosages) and menthol] on this core attentional function, which can be experimentally defined as speed of information processing. Substances were administered by inhalation; levels of alertness were assessed by measuring motor and reaction times in a reaction time paradigm. The performances of the six experimental groups receiving substances (n = 20 in four groups, n = 30 in two groups) were compared with those of corresponding control groups receiving water. Between-group analysis, i.e. comparisons between experimental groups and their respective control groups, mainly did not reach statistical significance. However, within-group analysis showed complex correlations between subjective evaluations of substances and objective performance, indicating that effects of essentials oils or their components on basic forms of attentional behavior are mainly psychological.

  17. Towards cross-lingual alerting for bursty epidemic events.

    PubMed

    Collier, Nigel

    2011-10-06

    Online news reports are increasingly becoming a source for event-based early warning systems that detect natural disasters. Harnessing the massive volume of information available from multilingual newswire presents as many challanges as opportunities due to the patterns of reporting complex spatio-temporal events. In this article we study the problem of utilising correlated event reports across languages. We track the evolution of 16 disease outbreaks using 5 temporal aberration detection algorithms on text-mined events classified according to disease and outbreak country. Using ProMED reports as a silver standard, comparative analysis of news data for 13 languages over a 129 day trial period showed improved sensitivity, F1 and timeliness across most models using cross-lingual events. We report a detailed case study analysis for Cholera in Angola 2010 which highlights the challenges faced in correlating news events with the silver standard. The results show that automated health surveillance using multilingual text mining has the potential to turn low value news into high value alerts if informed choices are used to govern the selection of models and data sources. An implementation of the C2 alerting algorithm using multilingual news is available at the BioCaster portal http://born.nii.ac.jp/?page=globalroundup.

  18. Volcanic Alert System (VAS) developed during the (2011-2013) El Hierro (Canary Islands) volcanic process

    NASA Astrophysics Data System (ADS)

    Ortiz, Ramon; Berrocoso, Manuel; Marrero, Jose Manuel; Fernandez-Ros, Alberto; Prates, Gonçalo; De la Cruz-Reyna, Servando; Garcia, Alicia

    2014-05-01

    In volcanic areas with long repose periods (as El Hierro), recently installed monitoring networks offer no instrumental record of past eruptions nor experience in handling a volcanic crisis. Both conditions, uncertainty and inexperience, contribute to make the communication of hazard more difficult. In fact, in the initial phases of the unrest at El Hierro, the perception of volcanic risk was somewhat distorted, as even relatively low volcanic hazards caused a high political impact. The need of a Volcanic Alert System became then evident. In general, the Volcanic Alert System is comprised of the monitoring network, the software tools for the analysis of the observables, the management of the Volcanic Activity Level, and the assessment of the threat. The Volcanic Alert System presented here places special emphasis on phenomena associated to moderate eruptions, as well as on volcano-tectonic earthquakes and landslides, which in some cases, as in El Hierro, may be more destructive than an eruption itself. As part of the Volcanic Alert System, we introduce here the Volcanic Activity Level which continuously applies a routine analysis of monitoring data (particularly seismic and deformation data) to detect data trend changes or monitoring network failures. The data trend changes are quantified according to the Failure Forecast Method (FFM). When data changes and/or malfunctions are detected, by an automated watchdog, warnings are automatically issued to the Monitoring Scientific Team. Changes in the data patterns are then translated by the Monitoring Scientific Team into a simple Volcanic Activity Level, that is easy to use and understand by the scientists and technicians in charge for the technical management of the unrest. The main feature of the Volcanic Activity Level is its objectivity, as it does not depend on expert opinions, which are left to the Scientific Committee, and its capabilities for early detection of precursors. As a consequence of the El Hierro experience we consider the objectivity of the Volcanic Activity Level a powerful tool to focus the discussions in a Scientific Committee on the activity forecast and on the expected scenarios, rather than on the multiple explanations of the data fluctuations, which is one of the main sources of conflict in the Scientific Committee discussions. Although the Volcanic Alert System was designed specifically for the unrest episodes at El Hierro, the involved methodologies may be applied to other situations of unrest.

  19. 76 FR 28131 - Federal Motor Vehicle Safety Standards; Motorcycle Helmets

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-13

    ..., this final rule sets a quasi-static load application rate for the helmet retention system; revises the... Analysis and Conclusion e. Quasi-Static Retention Test f. Helmet Conditioning Tolerances g. Other... it as a quasi-static test, instead of a static test. Specifying the application rate will aid...

  20. Decision Support Alerts for Medication Ordering in a Computerized Provider Order Entry (CPOE) System

    PubMed Central

    Beccaro, M. A. Del; Villanueva, R.; Knudson, K. M.; Harvey, E. M.; Langle, J. M.; Paul, W.

    2010-01-01

    Objective We sought to determine the frequency and type of decision support alerts by location and ordering provider role during Computerized Provider Order Entry (CPOE) medication ordering. Using these data we adjusted the decision support tools to reduce the number of alerts. Design Retrospective analyses were performed of dose range checks (DRC), drug-drug interaction and drug-allergy alerts from our electronic medical record. During seven sampling periods (each two weeks long) between April 2006 and October 2008 all alerts in these categories were analyzed. Another audit was performed of all DRC alerts by ordering provider role from November 2008 through January 2009. Medication ordering error counts were obtained from a voluntary error reporting system. Measurement/Results Between April 2006 and October 2008 the percent of medication orders that triggered a dose range alert decreased from 23.9% to 7.4%. The relative risk (RR) for getting an alert was higher at the start of the interventions versus later (RR= 2.40, 95% CI 2.28-2.52; p< 0.0001). The percentage of medication orders that triggered alerts for drug-drug interactions also decreased from 13.5% to 4.8%. The RR for getting a drug interaction alert at the start was 1.63, 95% CI 1.60-1.66; p< 0.0001. Alerts decreased in all clinical areas without an increase in reported medication errors. Conclusion We reduced the quantity of decision support alerts in CPOE using a systematic approach without an increase in reported medication errors PMID:23616845

  1. Determining Inappropriate Medication Alerts from "Inaccurate Warning" Overrides in the Intensive Care Unit.

    PubMed

    Rehr, Christine A; Wong, Adrian; Seger, Diane L; Bates, David W

    2018-04-01

     This article aims to understand provider behavior around the use of the override reason "Inaccurate warning," specifically whether it is an effective way of identifying unhelpful medication alerts.  We analyzed alert overrides that occurred in the intensive care units (ICUs) of a major academic medical center between June and November 2016, focused on the following high-significance alert types: dose, drug-allergy alerts, and drug-drug interactions (DDI). Override appropriateness was analyzed by two independent reviewers using predetermined criteria.  A total of 268 of 26,501 ICU overrides (1.0%) used the reason "Inaccurate warning," with 93 of these overrides associated with our included alert types. Sixty-one of these overrides (66%) were identified to be appropriate. Twenty-one of 30 (70%) dose alert overrides were appropriate. Forty of 48 drug-allergy alert overrides (83%) were appropriate, for reasons ranging from prior tolerance ( n  = 30) to inaccurate ingredient matches ( n  = 5). None of the 15 DDI overrides were appropriate.  The "Inaccurate warning" reason was selectively used by a small proportion of providers and overrides using this reason identified important opportunities to reduce excess alerts. Potential opportunities include improved evaluation of dosing mechanisms based on patient characteristics, inclusion of institutional dosing protocols to alert logic, and evaluation of a patient's prior tolerance to a medication that they have a documented allergy for. This resource is not yet routinely used for alert tailoring at our institution but may prove to be a valuable resource to evaluate available alerts. Schattauer GmbH Stuttgart.

  2. Data Link Test and Analysis System/TCAS Monitor User's Guide

    DOT National Transportation Integrated Search

    1991-02-01

    This document is a user's guide for the Data Link Test and Analysis System : (DATAS) Traffic Alert and Collision Avoidance System (TCAS) monitor application. : It provides a brief overall hardware description of DATAS configured as a TCAS : Monitor, ...

  3. Frankfurt, Germany: 1030/1090 MegaHertz Signal Analysis

    DOT National Transportation Integrated Search

    1996-07-01

    The Data Link Test Analysis System (DATAS) was used in the Frankfort, Germany : to collect data in the frequency band used by Air Traffic Control Radar : Beacon (ATCRBS), Mode Select (Mode S), and Traffic Alert and Collision : Avoidance (TCAS). Data ...

  4. Speech Alarms Pilot Study

    NASA Technical Reports Server (NTRS)

    Sandor, A.; Moses, H. R.

    2016-01-01

    Currently on the International Space Station (ISS) and other space vehicles Caution & Warning (C&W) alerts are represented with various auditory tones that correspond to the type of event. This system relies on the crew's ability to remember what each tone represents in a high stress, high workload environment when responding to the alert. Furthermore, crew receive a year or more in advance of the mission that makes remembering the semantic meaning of the alerts more difficult. The current system works for missions conducted close to Earth where ground operators can assist as needed. On long duration missions, however, they will need to work off-nominal events autonomously. There is evidence that speech alarms may be easier and faster to recognize, especially during an off-nominal event. The Information Presentation Directed Research Project (FY07-FY09) funded by the Human Research Program included several studies investigating C&W alerts. The studies evaluated tone alerts currently in use with NASA flight deck displays along with candidate speech alerts. A follow-on study used four types of speech alerts to investigate how quickly various types of auditory alerts with and without a speech component - either at the beginning or at the end of the tone - can be identified. Even though crew were familiar with the tone alert from training or direct mission experience, alerts starting with a speech component were identified faster than alerts starting with a tone. The current study replicated the results from the previous study in a more rigorous experimental design to determine if the candidate speech alarms are ready for transition to operations or if more research is needed. Four types of alarms (caution, warning, fire, and depressurization) were presented to participants in both tone and speech formats in laboratory settings and later in the Human Exploration Research Analog (HERA). In the laboratory study, the alerts were presented by software and participants were asked to identify the alert as quickly and as accurately as possible. Reaction time and accuracy were measured. Participants identified speech alerts significantly faster than tone alerts. The HERA study investigated the performance of participants in a flight-like environment. Participants were instructed to complete items on a task list and respond to C&W alerts as they occurred. Reaction time and accuracy were measured to determine if the benefits of speech alarms are still present in an applied setting.

  5. For whom the bell tolls: Silver Alerts raise concerns regarding individual rights and governmental interests.

    PubMed

    Wasser, Tobias D; Fox, Patrick K

    2013-01-01

    The Silver Alert system was initially created to help protect missing persons who have cognitive impairments, particularly the elderly. The Silver Alert is modeled after the Amber Alert, created to help locate and safeguard missing children. Unlike the Amber Alert, however, in most states the Silver Alert applies to the elderly, adults with a mental impairment, or both, depending on the state. The goal of the Silver Alert system is the quick dissemination of information about missing persons to law enforcement personnel as well as to the general public. Previously, states notified law enforcement personnel of missing persons through teletype to other public safety jurisdictions to enlist their assistance in the retrieval of the missing person. Silver Alert programs substantially expand the notification to include the general public, who receive information through radio and television broadcasts as well as highway billboards. The programs serve a legitimate governmental interest by protecting a vulnerable population from possible harm. Yet, the implementation of these alerts can have unintended consequences, including the possible violation of an individual's right to privacy. Such consequences require careful consideration.

  6. Evaluation of Helmet Mounted Display Alerting Symbology

    NASA Technical Reports Server (NTRS)

    DeMaio, Joe; Rutkowski, Michael (Technical Monitor)

    2000-01-01

    Proposed helicopter helmet mounted displays will be used to alert the pilot to a variety of conditions, from threats to equipment problems. The present research was performed under the NASA Safe All-weather Flight Operations Research (SAFOR) program supported by a joint Army/NASA research agreement. The purpose of the research was to examine ways to optimize the alerting effectiveness of helmet display symbology. The research used two approaches to increasing the effectiveness of alerts. One was to increase the ability of the alert to attract attention by using the entire display surface. The other was to include information about the required response in the alert itself. The investigation was conducted using the NASA Ames Research Center's six-degree-of-freedom vertical motion simulator (VMS) with a rotorcraft cockpit. Helmet display symbology was based on the AH-64's pilot night vision system (PNVS), cruise mode symbology. A standardized mission was developed, that consisted of 11 legs. The mission included four tasks, which allowed variation in the frequency of alerts. The general trend in the data points to a small benefit from both the full-screen alert and the partial information alert.

  7. 47 CFR 10.240 - Notification to new subscribers of non-participation in CMAS.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...-participation in CMAS. 10.240 Section 10.240 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Election to Participate in Commercial Mobile Alert System § 10.240... EMERGENCY ALERTS (Commercial Mobile Alert Service) [[CMS provider

  8. 47 CFR 10.320 - Provider alert gateway requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 1 2014-10-01 2014-10-01 false Provider alert gateway requirements. 10.320 Section 10.320 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.320 Provider alert gateway requirements. This section specifies the functions...

  9. 47 CFR 10.320 - Provider alert gateway requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 1 2013-10-01 2013-10-01 false Provider alert gateway requirements. 10.320 Section 10.320 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.320 Provider alert gateway requirements. This section specifies the functions...

  10. 47 CFR 10.410 - Prioritization.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 1 2012-10-01 2012-10-01 false Prioritization. 10.410 Section 10.410 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Alert Message... required to transmit Imminent Threat Alerts and AMBER Alerts on a first in-first out (FIFO) basis. ...

  11. Commercial Motor Vehicle Driver Fatigue And Alertness Study Executive Summary

    DOT National Transportation Integrated Search

    1996-11-01

    THE DRIVER FATIGUE AND ALERTNESS STUDY (DFAS) WAS THE LARGEST AND MOST COMPREHENSIVE OVER-THE-ROAD STUDY EVER CONDUCTED ON DRIVER FATIGUE AND ALERTNESS IN NORTH AMERICA. IT PROVIDES EXTENSIVE INFORMATION ON THE ALERTNESS, DRIVING PERFORMANCE, AND PHY...

  12. 47 CFR 11.56 - Obligation to process CAP-formatted EAS messages.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...), and Common Alerting Protocol, v. 1.2 USA Integrated Public Alert and Warning System Profile Version 1...) “Common Alerting Protocol, v. 1.2 USA Integrated Public Alert and Warning System Profile Version 1.0” (Oct...

  13. 47 CFR 11.56 - Obligation to process CAP-formatted EAS messages.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...), and Common Alerting Protocol, v. 1.2 USA Integrated Public Alert and Warning System Profile Version 1...) “Common Alerting Protocol, v. 1.2 USA Integrated Public Alert and Warning System Profile Version 1.0” (Oct...

  14. 47 CFR 11.56 - Obligation to process CAP-formatted EAS messages.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...), and Common Alerting Protocol, v. 1.2 USA Integrated Public Alert and Warning System Profile Version 1...) “Common Alerting Protocol, v. 1.2 USA Integrated Public Alert and Warning System Profile Version 1.0” (Oct...

  15. Development and Implementation of Sepsis Alert Systems.

    PubMed

    Harrison, Andrew M; Gajic, Ognjen; Pickering, Brian W; Herasevich, Vitaly

    2016-06-01

    Development and implementation of sepsis alert systems is challenging, particularly outside the monitored intensive care unit (ICU) setting. Barriers to wider use of sepsis alerts include evolving clinical definitions of sepsis, information overload, and alert fatigue, due to suboptimal alert performance. Outside the ICU, barriers include differences in health care delivery models, charting behaviors, and availability of electronic data. Current evidence does not support routine use of sepsis alert systems in clinical practice. Continuous improvement in the afferent and efferent aspects will help translate theoretic advantages into measurable patient benefit. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Closing the loop in ICU decision support: physiologic event detection, alerts, and documentation.

    PubMed Central

    Norris, P. R.; Dawant, B. M.

    2001-01-01

    Automated physiologic event detection and alerting is a challenging task in the ICU. Ideally care providers should be alerted only when events are clinically significant and there is opportunity for corrective action. However, the concepts of clinical significance and opportunity are difficult to define in automated systems, and effectiveness of alerting algorithms is difficult to measure. This paper describes recent efforts on the Simon project to capture information from ICU care providers about patient state and therapy in response to alerts, in order to assess the value of event definitions and progressively refine alerting algorithms. Event definitions for intracranial pressure and cerebral perfusion pressure were studied by implementing a reliable system to automatically deliver alerts to clinical users alphanumeric pagers, and to capture associated documentation about patient state and therapy when the alerts occurred. During a 6-month test period in the trauma ICU at Vanderbilt University Medical Center, 530 alerts were detected in 2280 hours of data spanning 14 patients. Clinical users electronically documented 81% of these alerts as they occurred. Retrospectively classifying documentation based on therapeutic actions taken, or reasons why actions were not taken, provided useful information about ways to potentially improve event definitions and enhance system utility. PMID:11825238

  17. Electronic Health Record Alert-Related Workload as a Predictor of Burnout in Primary Care Providers.

    PubMed

    Gregory, Megan E; Russo, Elise; Singh, Hardeep

    2017-07-05

    Electronic health records (EHRs) have been shown to increase physician workload. One EHR feature that contributes to increased workload is asynchronous alerts (also known as inbox notifications) related to test results, referral responses, medication refill requests, and messages from physicians and other health care professionals. This alert-related workload results in negative cognitive outcomes, but its effect on affective outcomes, such as burnout, has been understudied. To examine EHR alert-related workload (both objective and subjective) as a predictor of burnout in primary care providers (PCPs), in order to ultimately inform interventions aimed at reducing burnout due to alert workload. A cross-sectional questionnaire and focus group of 16 PCPs at a large medical center in the southern United States. Subjective, but not objective, alert workload was related to two of the three dimensions of burnout, including physical fatigue (p = 0.02) and cognitive weariness (p = 0.04), when controlling for organizational tenure. To reduce alert workload and subsequent burnout, participants indicated a desire to have protected time for alert management, fewer unnecessary alerts, and improvements to the EHR system. Burnout associated with alert workload may be in part due to subjective differences at an individual level, and not solely a function of the objective work environment. This suggests the need for both individual and organizational-level interventions to improve alert workload and subsequent burnout. Additional research should confirm these findings in larger, more representative samples.

  18. Wireless clinical alerts and patient outcomes in the surgical intensive care unit.

    PubMed

    Major, Kevin; Shabot, M Michael; Cunneen, Scott

    2002-12-01

    Errors in medicine have gained public interest since the Institute of Medicine published its 1999 report on this subject. Although errors of commission are frequently cited, errors of omission can be equally serious. A computerized surgical intensive care unit (SICU) information system when coupled to an event-driven alerting engine has the potential to reduce errors of omission for critical intensive care unit events. Automated alerts and patient outcomes were prospectively collected for all patients admitted to a tertiary-care SICU for a 2-year period. During the study period 3,973 patients were admitted to the SICU and received 13,608 days of care. A total of 15,066 alert pages were sent including alerts for physiologic condition (6,163), laboratory data (4,951), blood gas (3,774), drug allergy (130), and toxic drug levels (48). Admission Simplified Acute Physiology Score and Acute Physiology and Chronic Health Evaluation II score, SICU lengths of stay, and overall mortality rates were significantly higher in patients who triggered the alerting system. Patients triggering the alert paging system were 49.4 times more likely to die in the SICU compared with patients who did not generate an alert. Even after transfer to floor care the patients who triggered the alerting system were 5.7 times more likely to die in the hospital. An alert page identifies patients who will stay in the SICU longer and have a significantly higher chance of death compared with patients who do not trigger the alerting system.

  19. An Investigation of Drug-Drug Interaction Alert Overrides at a Pediatric Hospital.

    PubMed

    Humphrey, Kate; Jorina, Maria; Harper, Marvin; Dodson, Brenda; Kim, Seung-Yeon; Ozonoff, Al

    2018-05-01

    Drug-drug interactions (DDIs) can result in patient harm. DDI alerts are intended to help prevent harm; when the majority of alerts presented to providers are being overridden, their value is diminished. Our objective was to evaluate the overall rates of DDI alert overrides and how rates varied by specialty, clinician type, and patient complexity. A retrospective study of DDI alert overrides that occurred during 2012 and 2013 within the inpatient setting described at the medication-, hospital-, provider-, and patient encounter-specific levels was performed at an urban, quaternary-care, pediatric hospital. There were >41 000 DDI alerts presented to clinicians; ∼90% were overridden. The 5 DDI pairs that were most frequently presented and overridden included the following: potassium chloride-spironolactone, methadone-ondansetron, ketorolac-ibuprofen, cyclosporine-fluconazole, and potassium chloride-enalapril, each with an alert override rate of ≥0.89. Override rates across provider groups ranged between 0.84 and 0.97. In general, patients with high complexity had a higher frequency of alert overrides, but the rates of alert overrides for each DDI pairing did not differ significantly. High rates of DDI alert overrides occur across medications, provider groups, and patient encounters. Methods to decrease DDI alerts which are likely to be overridden exist, but it is also clear that more robust and intelligent tools are needed. Characteristics exist at the medication, hospital, provider, and patient levels that can be used to help specialize and enhance information transmission. Copyright © 2018 by the American Academy of Pediatrics.

  20. Geographic Variation in Rosiglitazone Use Surrounding FDA Warnings in the Department of Veterans Affairs.

    PubMed

    Ahuja, Vishal; Sohn, Min-Woong; Birge, John R; Syverson, Chad; Budiman-Mak, Elly; Emanuele, Nicholas; Cooper, Jennifer M; Huang, Elbert S

    2015-12-01

    Geographic variation in the use of prescription drugs, particularly those deemed harmful by the FDA, may lead to variation in patient exposure to adverse drug events. One such drug is the glucose-lowering drug rosiglitazone, for which the FDA issued a safety alert on May 21, 2007, following the publication of a meta-analysis that suggested a 43% increase in the risk of myocardial infarction with the use of rosiglitazone. This alert was followed by a black box warning on August 14, 2007, that was updated 3 months later. While large declines have been documented in rosiglitazone use in clinical practice, little is known about how the use of rosiglitazone and other glucose-lowering drugs varied within the Department of Veterans Affairs (VA), surrounding the FDA alerts. Understanding this variation within integrated health care systems is essential to formulating policies that enhance patient protection and quality of care. To document variation in the use of rosiglitazone and other glucose- lowering drugs across 21 Veterans Integrated Service Networks (VISNs). We conducted a retrospective analysis of drug use patterns for all major diabetes drugs in a national cohort of 550,550 veterans with diabetes from 2003 to 2008. This included the time periods when rosiglitazone was added to (November 2003) and removed from (October 2007) the VA national formulary (VANF). We employed multivariable logistic regression models to statistically estimate the association between a patient's location and the patient's odds of using rosiglitazone. Aggregate rosiglitazone use increased monotonically from 7.7%, in the quarter it was added to the VANF (November 4, 2003), to a peak of 15.3% in the quarter when the FDA issued the safety alert. Rosiglitazone use decreased sharply afterwards, reaching 3.4% by the end of the study period (September 30, 2008). The use of pioglitazone, another glucose-lowering drug in the same class as rosiglitazone, was low when the FDA issued the safety alert (0.4%) but increased sharply afterwards, reaching 3.6% by the end of the study period. Insulin use increased monotonically; metformin use remained relatively flat; and sulfonylurea use exhibited a general declining trend throughout the study period. Statistically significant geographic variation was observed in rosiglitazone use throughout the study period. The prevalence range, defined as the range of minimum to maximum use across VISNs was 3.7%-12.4% in the first quarter (January 1 to March 31, 2003); 1.0%-5.5% in the last quarter of study period (July 1 to September 30, 2008); and reached a peak of 9.6%-25.5% in the quarter when the FDA safety alert was issued (April 1 to March 31, 2007). In 5 VISNs, peak rosiglitazone use occurred before the FDA issued the safety alert. The odds ratio of using rosiglitazone in a given VISN varied from 0.55 (95% CI = 0.52-0.59; VISN 10) to 1.58 (95% CI = 1.50-1.66; VISN 15), with VISN 1 being the reference region. The variation was higher in the periods after the FDA issued the safety alert. Much less variation was observed in the use of pioglitazone, metformin, sulfonylurea, and insulin. Our results show statistically significant variation in the way VISNs within the VA responded to the FDA alerts, suggesting a need for mechanisms that disseminate information and guidelines for drug use in a consistent and reliable manner. Further study of regions that adopted ideal practices earlier may provide lessons for regional leadership and practice culture within integrated health care systems.

  1. 47 CFR 10.320 - Provider alert gateway requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 1 2012-10-01 2012-10-01 false Provider alert gateway requirements. 10.320 Section 10.320 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.320 Provider alert gateway requirements. This section specifies the functions...

  2. 77 FR 41331 - Commercial Mobile Alert System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-13

    ... Mobile Alert System AGENCY: Federal Communications Commission. ACTION: Final rule; announcement of... with the Commission's Commercial Mobile Alert System (CMS), Second Report and Order (``CMAS Second... Alert System rules contained in the Commission's Second Report and Order, FCC 08- 164, published at 73...

  3. 47 CFR 80.1111 - Distress alerting.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE... Safety Communications § 80.1111 Distress alerting. (a) The transmission of a distress alert indicates... distress message format, which is relayed through space stations. (b) The distress alert must be sent...

  4. 47 CFR 80.1111 - Distress alerting.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE... Safety Communications § 80.1111 Distress alerting. (a) The transmission of a distress alert indicates... distress message format, which is relayed through space stations. (b) The distress alert must be sent...

  5. 47 CFR 80.1111 - Distress alerting.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE... Safety Communications § 80.1111 Distress alerting. (a) The transmission of a distress alert indicates... distress message format, which is relayed through space stations. (b) The distress alert must be sent...

  6. 47 CFR 80.1111 - Distress alerting.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE... Safety Communications § 80.1111 Distress alerting. (a) The transmission of a distress alert indicates... distress message format, which is relayed through space stations. (b) The distress alert must be sent...

  7. 47 CFR 80.1111 - Distress alerting.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE... Safety Communications § 80.1111 Distress alerting. (a) The transmission of a distress alert indicates... distress message format, which is relayed through space stations. (b) The distress alert must be sent...

  8. Static and dynamic stability analysis of the space shuttle vehicle-orbiter

    NASA Technical Reports Server (NTRS)

    Chyu, W. J.; Cavin, R. K.; Erickson, L. L.

    1978-01-01

    The longitudinal static and dynamic stability of a Space Shuttle Vehicle-Orbiter (SSV Orbiter) model is analyzed using the FLEXSTAB computer program. Nonlinear effects are accounted for by application of a correction technique in the FLEXSTAB system; the technique incorporates experimental force and pressure data into the linear aerodynamic theory. A flexible Orbiter model is treated in the static stability analysis for the flight conditions of Mach number 0.9 for rectilinear flight (1 g) and for a pull-up maneuver (2.5 g) at an altitude of 15.24 km. Static stability parameters and structural deformations of the Orbiter are calculated at trim conditions for the dynamic stability analysis, and the characteristics of damping in pitch are investigated for a Mach number range of 0.3 to 1.2. The calculated results for both the static and dynamic stabilities are compared with the available experimental data.

  9. Alert Triage v 0.1 beta

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Doak, Justin E.; Ingram, Joe; Johnson, Josh

    2016-01-06

    In the cyber security operations of a typical organization, data from multiple sources are monitored, and when certain conditions in the data are met, an alert is generated in an alert management system. Analysts inspect these alerts to decide if any deserve promotion to an event requiring further scrutiny. This triage process is manual, time-consuming, and detracts from the in-depth investigation of events. We have created a software system that uses supervised machine learning to automatically prioritize these alerts. In particular we utilize active learning to make efficient use of the pool of unlabeled alerts, thereby improving the performance ofmore » our ranking models over passive learning. We have demonstrated the effectiveness of our system on a large, real-world dataset of cyber security alerts.« less

  10. Theoretical research and experimental validation of quasi-static load spectra on bogie frame structures of high-speed trains

    NASA Astrophysics Data System (ADS)

    Zhu, Ning; Sun, Shou-Guang; Li, Qiang; Zou, Hua

    2014-12-01

    One of the major problems in structural fatigue life analysis is establishing structural load spectra under actual operating conditions. This study conducts theoretical research and experimental validation of quasi-static load spectra on bogie frame structures of high-speed trains. The quasistatic load series that corresponds to quasi-static deformation modes are identified according to the structural form and bearing conditions of high-speed train bogie frames. Moreover, a force-measuring frame is designed and manufactured based on the quasi-static load series. The load decoupling model of the quasi-static load series is then established via calibration tests. Quasi-static load-time histories, together with online tests and decoupling analysis, are obtained for the intermediate range of the Beijing—Shanghai dedicated passenger line. The damage consistency calibration of the quasi-static discrete load spectra is performed according to a damage consistency criterion and a genetic algorithm. The calibrated damage that corresponds with the quasi-static discrete load spectra satisfies the safety requirements of bogie frames.

  11. Lack of utility of a decision support system to mitigate delays in admission from the operating room to the postanesthesia care unit.

    PubMed

    Ehrenfeld, Jesse M; Dexter, Franklin; Rothman, Brian S; Minton, Betty Sue; Johnson, Diane; Sandberg, Warren S; Epstein, Richard H

    2013-12-01

    When the phase I postanesthesia care unit (PACU) is at capacity, completed cases need to be held in the operating room (OR), causing a "PACU delay." Statistical methods based on historical data can optimize PACU staffing to achieve the least possible labor cost at a given service level. A decision support process to alert PACU charge nurses that the PACU is at or near maximum census might be effective in lessening the incidence of delays and reducing over-utilized OR time, but only if alerts are timely (i.e., neither too late nor too early to act upon) and the PACU slot can be cleared quickly. We evaluated the maximum potential benefit of such a system, using assumptions deliberately biased toward showing utility. We extracted 3 years of electronic PACU data from a tertiary care medical center. At this hospital, PACU admissions were limited by neither inadequate PACU staffing nor insufficient PACU beds. We developed a model decision support system that simulated alerts to the PACU charge nurse. PACU census levels were reconstructed from the data at a 1-minute level of resolution and used to evaluate if subsequent delays would have been prevented by such alerts. The model assumed there was always a patient ready for discharge and an available hospital bed. The time from each alert until the maximum census was exceeded ("alert lead time") was determined. Alerts were judged to have utility if the alert lead time fell between various intervals from 15 or 30 minutes to 60, 75, or 90 minutes after triggering. In addition, utility for reducing over-utilized OR time was assessed using the model by determining if 2 patients arrived from 5 to 15 minutes of each other when the PACU census was at 1 patient less than the maximum census. At most, 23% of alerts arrived 30 to 60 minutes prior to the admission that resulted in the PACU exceeding the specified maximum capacity. When the notification window was extended to 15 to 90 minutes, the maximum utility was <50%. At most, 45% of alerts potentially would have resulted in reassigning the last available PACU slot to 1 OR versus another within 15 minutes of the original assignment. Despite multiple biases that favored effectiveness, the maximum potential benefit of a decision support system to mitigate PACU delays on the day on the surgery was below the 70% minimum threshold for utility of automated decision support messages, previously established via meta-analysis. Neither reduction in PACU delays nor reassigning promised PACU slots based on reducing over-utilized OR time were realized sufficiently to warrant further development of the system. Based on these results, the only evidence-based method of reducing PACU delays is to adjust PACU staffing and staff scheduling using computational algorithms to match the historical workload (e.g., as developed in 2001).

  12. Building a Communication, Education, an Outreach Program for the ShakeAlert National Earthquake Early Warning Program - Recommendations for Public Alerts Via Cell Phones

    NASA Astrophysics Data System (ADS)

    DeGroot, R. M.; Long, K.; Strauss, J. A.

    2017-12-01

    The United States Geological Survey (USGS) and its partners are developing the ShakeAlert Earthquake Early Warning System for the West Coast of the United States. To be an integral part of successful implementation, ShakeAlert engagement programs and materials must integrate with and leverage broader earthquake risk programs. New methods and products for dissemination must be multidisciplinary, cost effective, and consistent with existing hazards education and communication efforts. The ShakeAlert Joint Committee for Communication, Education, and Outreach (JCCEO), is identifying, developing, and cultivating partnerships with ShakeAlert stakeholders including Federal, State, academic partners, private companies, policy makers, and local organizations. Efforts include developing materials, methods for delivery, and reaching stakeholders with information on ShakeAlert, earthquake preparedness, and emergency protective actions. It is essential to develop standards to ensure information communicated via the alerts is consistent across the public and private sector and achieving a common understanding of what actions users take when they receive a ShakeAlert warning. In February 2017, the JCCEO convened the Warning Message Focus Group (WMFG) to provide findings and recommendations to the Alliance for Telecommunications Industry Solutions on the use of earthquake early warning message content standards for public alerts via cell phones. The WMFG represents communications, education, and outreach stakeholders from various sectors including ShakeAlert regional coordinators, industry, emergency managers, and subject matter experts from the social sciences. The group knowledge was combined with an in-depth literature review to ensure that all groups who could receive the message would be taken into account. The USGS and the participating states and agencies acknowledge that the implementation of ShakeAlert is a collective effort requiring the participation of hundreds of stakeholders committed to ensuring public accessibility.

  13. Does integrating nonurgent, clinically significant radiology alerts within the electronic health record impact closed-loop communication and follow-up?

    PubMed Central

    Dalal, Anuj K; Sahni, V Anik; Lacson, Ronilda; Khorasani, Ramin

    2016-01-01

    Objective To assess whether integrating critical result management software—Alert Notification of Critical Results (ANCR)—with an electronic health record (EHR)-based results management application impacts closed-loop communication and follow-up of nonurgent, clinically significant radiology results by primary care providers (PCPs). Materials and Methods This institutional review board-approved study was conducted at a large academic medical center. Postintervention, PCPs could acknowledge nonurgent, clinically significant ANCR-generated alerts (“alerts”) within ANCR or the EHR. Primary outcome was the proportion of alerts acknowledged via EHR over a 24-month postintervention. Chart abstractions for a random sample of alerts 12 months preintervention and 24 months postintervention were reviewed, and the follow-up rate of actionable alerts (eg, performing follow-up imaging, administering antibiotics) was estimated. Pre- and postintervention rates were compared using the Fisher exact test. Postintervention follow-up rate was compared for EHR-acknowledged alerts vs ANCR. Results Five thousand nine hundred and thirty-one alerts were acknowledged by 171 PCPs, with 100% acknowledgement (consistent with expected ANCR functionality). PCPs acknowledged 16% (688 of 4428) of postintervention alerts in the EHR, with the remaining in ANCR. Follow-up was documented for 85 of 90 (94%; 95% CI, 88%-98%) preintervention and 79 of 84 (94%; 95% CI, 87%-97%) postintervention alerts (P > .99). Postintervention, 11 of 14 (79%; 95% CI, 52%-92%) alerts were acknowledged via EHR and 68 of 70 (97%; 95% CI, 90%-99%) in ANCR had follow-up (P = .03). Conclusions Integrating ANCR and EHR provides an additional workflow for acknowledging nonurgent, clinically significant results without significant change in rates of closed-loop communication or follow-up of alerts. PMID:26335982

  14. Data link test and analysis system/TCAS monitor user's guide

    NASA Astrophysics Data System (ADS)

    Vandongen, John; Wapelhorst, Leo

    1991-02-01

    This document is a user's guide for the Data Link Test and Analysis System (DATAS) Traffic Alert and Collision Avoidance System (TCAS) monitor. It provides a brief overall hardware description of DATAS configured as a TCAS monitor, and the applications software.

  15. Does integrating nonurgent, clinically significant radiology alerts within the electronic health record impact closed-loop communication and follow-up?

    PubMed

    O'Connor, Stacy D; Dalal, Anuj K; Sahni, V Anik; Lacson, Ronilda; Khorasani, Ramin

    2016-03-01

    To assess whether integrating critical result management software--Alert Notification of Critical Results (ANCR)--with an electronic health record (EHR)-based results management application impacts closed-loop communication and follow-up of nonurgent, clinically significant radiology results by primary care providers (PCPs). This institutional review board-approved study was conducted at a large academic medical center. Postintervention, PCPs could acknowledge nonurgent, clinically significant ANCR-generated alerts ("alerts") within ANCR or the EHR. Primary outcome was the proportion of alerts acknowledged via EHR over a 24-month postintervention. Chart abstractions for a random sample of alerts 12 months preintervention and 24 months postintervention were reviewed, and the follow-up rate of actionable alerts (eg, performing follow-up imaging, administering antibiotics) was estimated. Pre- and postintervention rates were compared using the Fisher exact test. Postintervention follow-up rate was compared for EHR-acknowledged alerts vs ANCR. Five thousand nine hundred and thirty-one alerts were acknowledged by 171 PCPs, with 100% acknowledgement (consistent with expected ANCR functionality). PCPs acknowledged 16% (688 of 4428) of postintervention alerts in the EHR, with the remaining in ANCR. Follow-up was documented for 85 of 90 (94%; 95% CI, 88%-98%) preintervention and 79 of 84 (94%; 95% CI, 87%-97%) postintervention alerts (P > .99). Postintervention, 11 of 14 (79%; 95% CI, 52%-92%) alerts were acknowledged via EHR and 68 of 70 (97%; 95% CI, 90%-99%) in ANCR had follow-up (P = .03). Integrating ANCR and EHR provides an additional workflow for acknowledging nonurgent, clinically significant results without significant change in rates of closed-loop communication or follow-up of alerts. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Static aeroelastic analysis and tailoring of a single-element racing car wing

    NASA Astrophysics Data System (ADS)

    Sadd, Christopher James

    This thesis presents the research from an Engineering Doctorate research programme in collaboration with Reynard Motorsport Ltd, a manufacturer of racing cars. Racing car wing design has traditionally considered structures to be rigid. However, structures are never perfectly rigid and the interaction between aerodynamic loading and structural flexibility has a direct impact on aerodynamic performance. This interaction is often referred to as static aeroelasticity and the focus of this research has been the development of a computational static aeroelastic analysis method to improve the design of a single-element racing car wing. A static aeroelastic analysis method has been developed by coupling a Reynolds-Averaged Navier-Stokes CFD analysis method with a Finite Element structural analysis method using an iterative scheme. Development of this method has included assessment of CFD and Finite Element analysis methods and development of data transfer and mesh deflection methods. Experimental testing was also completed to further assess the computational analyses. The computational and experimental results show a good correlation and these studies have also shown that a Navier-Stokes static aeroelastic analysis of an isolated wing can be performed at an acceptable computational cost. The static aeroelastic analysis tool was used to assess methods of tailoring the structural flexibility of the wing to increase its aerodynamic performance. These tailoring methods were then used to produce two final wing designs to increase downforce and reduce drag respectively. At the average operating dynamic pressure of the racing car, the computational analysis predicts that the downforce-increasing wing has a downforce of C[1]=-1.377 in comparison to C[1]=-1.265 for the original wing. The computational analysis predicts that the drag-reducing wing has a drag of C[d]=0.115 in comparison to C[d]=0.143 for the original wing.

  17. 12 CFR 1022.121 - Active duty alerts.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 12 Banks and Banking 8 2014-01-01 2014-01-01 false Active duty alerts. 1022.121 Section 1022.121... Consumer Reporting Agencies Regarding Identity Theft § 1022.121 Active duty alerts. (a) Duration. The duration of an active duty alert shall be twelve months. ...

  18. 12 CFR 1022.121 - Active duty alerts.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 12 Banks and Banking 8 2013-01-01 2013-01-01 false Active duty alerts. 1022.121 Section 1022.121... Consumer Reporting Agencies Regarding Identity Theft § 1022.121 Active duty alerts. (a) Duration. The duration of an active duty alert shall be twelve months. ...

  19. 78 FR 22270 - Special Fraud Alert: Physician-Owned Entities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-15

    ...] Special Fraud Alert: Physician-Owned Entities AGENCY: Office of Inspector General (OIG), HHS. ACTION... Physician-Owned Entities. Specifically, the Special Fraud Alert addressed physician-owned entities that... publication of the Special Fraud Alert on Physician-Owned Entities, an inadvertent error appeared in the DATES...

  20. 76 FR 62321 - Airworthiness Directives; Aviation Communication & Surveillance Systems (ACSS) Traffic Alert and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-07

    ... Communication & Surveillance Systems (ACSS) Traffic Alert and Collision Avoidance System (TCAS) Units AGENCY... certain Aviation Communication & Surveillance Systems (ACSS) traffic alert and collision avoidance system...) traffic alert and collision avoidance system (TCAS) units with part numbers identified in ACSS Technical...

  1. 77 FR 26701 - Review of the Emergency Alert System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-07

    ... Emergency Alert System AGENCY: Federal Communications Commission. ACTION: Final rule. SUMMARY: In this document, the Federal Communications Commission (Commission) amends its rules governing the Emergency Alert... the manner in which EAS Participants must be able to receive alert messages formatted in the Common...

  2. Using the World Wide Web for GIDEP Problem Data Processing at Marshall Space Flight Center

    NASA Technical Reports Server (NTRS)

    McPherson, John W.; Haraway, Sandra W.; Whirley, J. Don

    1999-01-01

    Since April 1997, Marshall Space Flight Center has been using electronic transfer and the web to support our processing of the Government-Industry Data Exchange Program (GIDEP) and NASA ALERT information. Specific aspects include: (1) Extraction of ASCII text information from GIDEP for loading into Word documents for e-mail to ALERT actionees; (2) Downloading of GIDEP form image formats in Adobe Acrobat (.pdf) for internal storage display on the MSFC ALERT web page; (3) Linkage of stored GRDEP problem forms with summary information for access from the MSFC ALERT Distribution Summary Chart or from an html table of released MSFC ALERTs (4) Archival of historic ALERTs for reference by GIDEP ID, MSFC ID, or MSFC release date; (5) On-line tracking of ALERT response status using a Microsoft Access database and the web (6) On-line response to ALERTs from MSFC actionees through interactive web forms. The technique, benefits, effort, coordination, and lessons learned for each aspect are covered herein.

  3. Context-Sensitive Clinical Alert Packages Written in Arden Syntax.

    PubMed

    Zeckl, Julia; Adlassnig, Katharina; Fossler, Renate; Blacky, Alexander; de Bruin, Jeroen S; Koller, Walter; Rappelsberger, Andrea; Adlassnig, Klaus-Peter

    2017-01-01

    An increasing body of raw patient data is generated on each day of a patient's stay at a hospital. It is of paramount importance that critical patient information be extracted from these large data volumes and presented to the patient's clinical caregivers as early as possible. Contemporary clinical alert systems attempt to provide this service with moderate success. The efficacy of the systems is limited by the fact that they are too general to fit specific patient populations or healthcare institutions. In this study we present an extendable alerting framework implemented in Arden Syntax, which can be configured to the needs and preferences of healthcare institutions and individual patient caregivers. We illustrate the potential of this alerting framework via an alert package that analyzes hematological laboratory results with data from intensive care units at the Vienna General Hospital, Austria. The results show the effectiveness of this alert package and its ability to generate key alerts while avoiding over-alerting.

  4. Results of application of automatic computation of static corrections on data from the South Banat Terrain

    NASA Astrophysics Data System (ADS)

    Milojević, Slavka; Stojanovic, Vojislav

    2017-04-01

    Due to the continuous development of the seismic acquisition and processing method, the increase of the signal/fault ratio always represents a current target. The correct application of the latest software solutions improves the processing results and justifies their development. A correct computation and application of static corrections represents one of the most important tasks in pre-processing. This phase is of great importance for further processing steps. Static corrections are applied to seismic data in order to compensate the effects of irregular topography, the difference between the levels of source points and receipt in relation to the level of reduction, of close to the low-velocity surface layer (weathering correction), or any reasons that influence the spatial and temporal position of seismic routes. The refraction statics method is the most common method for computation of static corrections. It is successful in resolving of both the long-period statics problems and determining of the difference in the statics caused by abrupt lateral changes in velocity in close to the surface layer. XtremeGeo FlatironsTM is a program whose main purpose is computation of static correction through a refraction statics method and allows the application of the following procedures: picking of first arrivals, checking of geometry, multiple methods for analysis and modelling of statics, analysis of the refractor anisotropy and tomography (Eikonal Tomography). The exploration area is located on the southern edge of the Pannonian Plain, in the plain area with altitudes of 50 to 195 meters. The largest part of the exploration area covers Deliblato Sands, where the geological structure of the terrain and high difference in altitudes significantly affects the calculation of static correction. Software XtremeGeo FlatironsTM has powerful visualization and tools for statistical analysis which contributes to significantly more accurate assessment of geometry close to the surface layers and therefore more accurately computed static corrections.

  5. Using clinical simulation centers to test design interventions: a pilot study of lighting and color modifications.

    PubMed

    Gray, Whitney Austin; Kesten, Karen S; Hurst, Stephen; Day, Tama Duffy; Anderko, Laura

    2012-01-01

    The aim of this pilot study was to test design interventions such as lighting, color, and spatial color patterning on nurses' stress, alertness, and satisfaction, and to provide an example of how clinical simulation centers can be used to conduct research. The application of evidence-based design research in healthcare settings requires a transdisciplinary approach. Integrating approaches from multiple fields in real-life settings often proves time consuming and experimentally difficult. However, forums for collaboration such as clinical simulation centers may offer a solution. In these settings, identical operating and patient rooms are used to deliver simulated patient care scenarios using automated mannequins. Two identical rooms were modified in the clinical simulation center. Nurses spent 30 minutes in each room performing simulated cardiac resuscitation. Subjective measures of nurses' stress, alertness, and satisfaction were collected and compared between settings and across time using matched-pair t-test analysis. Nurses reported feeling less stressed after exposure to the experimental room than nurses who were exposed to the control room (2.22, p = .03). Scores post-session indicated a significant reduction in stress and an increase in alertness after exposure to the experimental room as compared to the control room, with significance levels below .10. (Change in stress scores: 3.44, p = .069); (change in alertness scores: 3.6, p = .071). This study reinforces the use of validated survey tools to measure stress, alertness, and satisfaction. Results support human-centered design approaches by evaluating the effect on nurses in an experimental setting.

  6. Analysis of clinical decision support system malfunctions: a case series and survey

    PubMed Central

    Wright, Adam; Hickman, Thu-Trang T; McEvoy, Dustin; Aaron, Skye; Ai, Angela; Andersen, Jan Marie; Hussain, Salman; Ramoni, Rachel; Fiskio, Julie; Sittig, Dean F; Bates, David W

    2016-01-01

    Objective To illustrate ways in which clinical decision support systems (CDSSs) malfunction and identify patterns of such malfunctions. Materials and Methods We identified and investigated several CDSS malfunctions at Brigham and Women’s Hospital and present them as a case series. We also conducted a preliminary survey of Chief Medical Information Officers to assess the frequency of such malfunctions. Results We identified four CDSS malfunctions at Brigham and Women’s Hospital: (1) an alert for monitoring thyroid function in patients receiving amiodarone stopped working when an internal identifier for amiodarone was changed in another system; (2) an alert for lead screening for children stopped working when the rule was inadvertently edited; (3) a software upgrade of the electronic health record software caused numerous spurious alerts to fire; and (4) a malfunction in an external drug classification system caused an alert to inappropriately suggest antiplatelet drugs, such as aspirin, for patients already taking one. We found that 93% of the Chief Medical Information Officers who responded to our survey had experienced at least one CDSS malfunction, and two-thirds experienced malfunctions at least annually. Discussion CDSS malfunctions are widespread and often persist for long periods. The failure of alerts to fire is particularly difficult to detect. A range of causes, including changes in codes and fields, software upgrades, inadvertent disabling or editing of rules, and malfunctions of external systems commonly contribute to CDSS malfunctions, and current approaches for preventing and detecting such malfunctions are inadequate. Conclusion CDSS malfunctions occur commonly and often go undetected. Better methods are needed to prevent and detect these malfunctions. PMID:27026616

  7. Improving Environmental Literacy through GO3 Citizen Science Project

    NASA Astrophysics Data System (ADS)

    Wilkening, B.

    2011-12-01

    In the Global Ozone (GO3) Project students measure ground-level ozone on a continuous basis and upload their results to a global network used by atmospheric scientists and schools. Students learn important concepts such as chemical measurement methods; instrumentation; calibration; data acquisition using computers; data quality; statistics; data analysis and graphing; posting of data to the web; the chemistry of air pollution; stratospheric ozone depletion and global climate change. Students collaborate with researchers and other students globally in the GO3 network. Wilson K-8 School is located in a suburban area in Pima County, Arizona. Throughout the year we receive high ozone alert days. Prior to joining the GO3 project, my students were unaware of air pollution alerts, risks and causes. In the past when Pima County issued alerts to the school, they were posted on signs around the school. No explanation was provided to the students and the signs were often left up for days. This discounted the potential health effects of the situation, resulting in the alerts effectively being ignored. The GO3 project is transforming both my students and our school community. Now my students are:

    • Performing science research
    • Utilizing technology and increasing their skills
    • Collaborating in a responsible manner on the global GO3 social network
    • Communicating their work to the community
    • Issuing their own ozone alerts to their school
    • Advocating for actions that will improve air quality
    My students participation in this citizen science project is creating a more cognizant and active community in regards to air pollution.

  8. Improving the effect of FDA-mandated drug safety alerts with Internet-based continuing medical education.

    PubMed

    Kraus, Carl N; Baldwin, Alan T; McAllister, R G

    2013-02-01

    The US Food and Drug Administration (FDA) requires risk communication as an element of Risk Evaluation and Mitigation Strategies (REMS) to alert and educate healthcare providers about severe toxicities associated with approved drugs. The educational effectiveness of this approach has not been evaluated. To support the communication plan element of the ipilimumab REMS, a Medscape Safe Use Alert (SUA) letter was distributed by Medscape via email and mobile device distribution to clinicians specified in the REMS. This alert contained the FDA-approved Dear Healthcare Provider (DHCP) letter mandated for distribution. A continuing medical education (CME) activity describing ipilimumab toxicities and the appropriate management was simultaneously posted on the website and distributed to Medscape members. Data were collected over a 6-month period regarding the handling of the letter and the responses to pre- and post-test questions for those who participated in the CME activity. Analysis of the answers to the pre- and posttest questions showed that participation in the CME activity resulted in an improvement in correct answer responses of 47%. Our experience shows that there are likely distinct information sources that are utilized by different HCP groups. The ready availability of a brief CME activity was utilized by 24,063 individuals, the majority of whom showed enhanced understanding of ipilimumab toxicity by improvement in post-test scores, educational data that are not available via implementation of standard safety alert communications. These results demonstrate that improvement in understanding of specific drug toxicities is enhanced by a CME intervention.

  9. Alert generation and cockpit presentation for an integrated microburst alerting system

    NASA Technical Reports Server (NTRS)

    Wanke, Craig; Hansman, R. John, Jr.

    1991-01-01

    Alert generation and cockpit presentation issues for low level wind shear (microburst) alerts are investigated. Alert generation issues center on the development of a hazard criterion which allows integration of both ground based and airborne wind shear detection systems to form an accurate picture of the aviation hazard posed by a particular wind shear situation. A methodology for the testing of a hazard criteria through flight simulation has been developed, and has been used to examine the effectiveness and feasibility of several possible criteria. Also, an experiment to evaluate candidate graphical cockpit displays for microburst alerts using a piloted simulator has been designed.

  10. Proposal of an in silico profiler for categorisation of repeat dose toxicity data of hair dyes.

    PubMed

    Nelms, M D; Ates, G; Madden, J C; Vinken, M; Cronin, M T D; Rogiers, V; Enoch, S J

    2015-05-01

    This study outlines the analysis of 94 chemicals with repeat dose toxicity data taken from Scientific Committee on Consumer Safety opinions for commonly used hair dyes in the European Union. Structural similarity was applied to group these chemicals into categories. Subsequent mechanistic analysis suggested that toxicity to mitochondria is potentially a key driver of repeat dose toxicity for chemicals within each of the categories. The mechanistic hypothesis allowed for an in silico profiler consisting of four mechanism-based structural alerts to be proposed. These structural alerts related to a number of important chemical classes such as quinones, anthraquinones, substituted nitrobenzenes and aromatic azos. This in silico profiler is intended for grouping chemicals into mechanism-based categories within the adverse outcome pathway paradigm.

  11. 12 CFR 1022.121 - Active duty alerts.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 12 Banks and Banking 8 2012-01-01 2012-01-01 false Active duty alerts. 1022.121 Section 1022.121... Consumer Reporting Agencies Regarding Identity Theft § 1022.121 Active duty alerts. (a) Duration. The duration of an active duty alert shall be twelve months. (b) [Reserved] ...

  12. 76 FR 3064 - Travelers Information Stations

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-19

    ... phone numbers when local 911 systems fail, terror threat alert levels, public health warnings ``and all... Alerts, alternate phone numbers when local 911 systems fail, terror threat alert levels, public health..., alternate phone numbers to 911, terror threat alert levels, and public health warnings--do not appear to be...

  13. 77 FR 33661 - Review of the Emergency Alert System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-07

    ... Emergency Alert System AGENCY: Federal Communications Commission. ACTION: Final rule; announcement of... Commission's Review of the Emergency Alert System, Fifth Report and Order (Order). This document is... Expiration Date: November 30, 2012. Title: Part 11--Emergency Alert System, Fifth Report and Order, FCC 12-7...

  14. Automated vocabulary discovery for geo-parsing online epidemic intelligence.

    PubMed

    Keller, Mikaela; Freifeld, Clark C; Brownstein, John S

    2009-11-24

    Automated surveillance of the Internet provides a timely and sensitive method for alerting on global emerging infectious disease threats. HealthMap is part of a new generation of online systems designed to monitor and visualize, on a real-time basis, disease outbreak alerts as reported by online news media and public health sources. HealthMap is of specific interest for national and international public health organizations and international travelers. A particular task that makes such a surveillance useful is the automated discovery of the geographic references contained in the retrieved outbreak alerts. This task is sometimes referred to as "geo-parsing". A typical approach to geo-parsing would demand an expensive training corpus of alerts manually tagged by a human. Given that human readers perform this kind of task by using both their lexical and contextual knowledge, we developed an approach which relies on a relatively small expert-built gazetteer, thus limiting the need of human input, but focuses on learning the context in which geographic references appear. We show in a set of experiments, that this approach exhibits a substantial capacity to discover geographic locations outside of its initial lexicon. The results of this analysis provide a framework for future automated global surveillance efforts that reduce manual input and improve timeliness of reporting.

  15. Usability Flaws in Medication Alerting Systems: Impact on Usage and Work System.

    PubMed

    Marcilly, R; Ammenwerth, E; Roehrer, E; Pelayo, S; Vasseur, F; Beuscart-Zéphir, M-C

    2015-08-13

    Previous research has shown that medication alerting systems face usability issues. There has been no previous attempt to systematically explore the consequences of usability flaws in such systems on users (i.e. usage problems) and work systems (i.e. negative outcomes). This paper aims at exploring and synthesizing the consequences of usability flaws in terms of usage problems and negative outcomes on the work system. A secondary analysis of 26 papers included in a prior systematic review of the usability flaws in medication alerting was performed. Usage problems and negative outcomes were extracted and sorted. Links between usability flaws, usage problems, and negative outcomes were also analyzed. Poor usability generates a large variety of consequences. It impacts the user from a cognitive, behavioral, emotional, and attitudinal perspective. Ultimately, usability flaws have negative consequences on the workflow, the effectiveness of the technology, the medication management process, and, more importantly, patient safety. Only few complete pathways leading from usability flaws to negative outcomes were identified. Usability flaws in medication alerting systems impede users, and ultimately their work system, and negatively impact patient safety. Therefore, the usability dimension may act as a hidden explanatory variable that could explain, at least partly, the (absence of) intended outcomes of new technology.

  16. Usability Flaws in Medication Alerting Systems: Impact on Usage and Work System

    PubMed Central

    Ammenwerth, E.; Roehrer, E.; Pelayo, S.; Vasseur, F.; Beuscart-Zéphir, M.-C.

    2015-01-01

    Summary Objectives Previous research has shown that medication alerting systems face usability issues. There has been no previous attempt to systematically explore the consequences of usability flaws in such systems on users (i.e. usage problems) and work systems (i.e. negative outcomes). This paper aims at exploring and synthesizing the consequences of usability flaws in terms of usage problems and negative outcomes on the work system. Methods A secondary analysis of 26 papers included in a prior systematic review of the usability flaws in medication alerting was performed. Usage problems and negative outcomes were extracted and sorted. Links between usability flaws, usage problems, and negative outcomes were also analyzed. Results Poor usability generates a large variety of consequences. It impacts the user from a cognitive, behavioral, emotional, and attitudinal perspective. Ultimately, usability flaws have negative consequences on the workflow, the effectiveness of the technology, the medication management process, and, more importantly, patient safety. Only few complete pathways leading from usability flaws to negative outcomes were identified. Conclusion Usability flaws in medication alerting systems impede users, and ultimately their work system, and negatively impact patient safety. Therefore, the usability dimension may act as a hidden explanatory variable that could explain, at least partly, the (absence of) intended outcomes of new technology. PMID:26123906

  17. Adoption of medication alert systems in hospital outpatient departments in Taiwan.

    PubMed

    Kuo, Yu-Chun; Cheng, Shou-Hsia

    2017-06-01

    The adoption of medication alert systems in the health care sector varies among regions. In Taiwan, the health authority introduced policies in 2005 to encourage the adoption of medication alert systems in hospitals. This study aimed to understand the adoption of medication alert systems in the outpatient departments of hospitals in Taiwan using a nationwide survey. A questionnaire was developed and mailed to 380 accredited general hospitals in Taiwan in 2013. The information collected from the questionnaire concerning the outpatient department included (1) the time of adoption of a medication alert system; (2) the operation of individual alert functions: availability, management, and stability; and (3) hospital characteristics: accreditation level, teaching status, ownership, and number of beds. A total of 216 hospitals completed and returned the questionnaire, corresponding to a response rate of 56.8%. The adoption rate of medication alert systems in hospital outpatient departments increased from less than 10% in 1997-95.83% in 2012. Approximately two-thirds of the hospitals developed and maintained the alert systems independently or collaboratively with vendors. Teaching and large hospitals tended to develop more advanced alert functions such as drug-drug interaction functions. Improving the safety and quality of pharmaceutical services and meeting the policy requirements are reasons for hospitals to establish medication alert systems. The adoption rate of medication alert systems reached 95% in accredited general hospitals in Taiwan. Government policy and available health information professionals and vendors may somewhat contribute to the high adoption rate. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Adherence to drug-drug interaction alerts in high-risk patients: a trial of context-enhanced alerting.

    PubMed

    Duke, Jon D; Li, Xiaochun; Dexter, Paul

    2013-05-01

    Drug-drug interaction (DDI) alerting is an important form of clinical decision support, yet physicians often fail to attend to critical DDI warnings due to alert fatigue. We previously described a model for highlighting patients at high risk of a DDI by enhancing alerts with relevant laboratory data. We sought to evaluate the effect of this model on alert adherence in high-risk patients. A 6-month randomized controlled trial involving 1029 outpatient physicians was performed. The target interactions were all DDIs known to cause hyperkalemia. Alerts in the intervention group were enhanced with the patient's most recent potassium and creatinine levels. The control group received unmodified alerts. High -risk patients were those with baseline potassium >5.0 mEq/l and/or creatinine ≥1.5 mg/dl (132 μmol/l). We found no significant difference in alert adherence in high-risk patients between the intervention group (15.3%) and the control group (16.8%) (p=0.71). Adherence in normal risk patients was significantly lower in the intervention group (14.6%) than in the control group (18.6%) (p<0.01). In neither group did physicians increase adherence in patients at high risk. Physicians adhere poorly to hyperkalemia-associated DDI alerts even in patients with risk factors for a clinically significant interaction, and the display of relevant laboratory data in these alerts did not improve adherence levels in the outpatient setting. Further research is necessary to determine optimal strategies for conveying patient-specific DDI risk.

  19. The effect of automated alerts on preoperative anemia management.

    PubMed

    Dilla, Andrew; Wisniewski, Mary Kay; Waters, Jonathan H; Triulzi, Darrell J; Yazer, Mark H

    2015-04-01

    This study evaluated the role of an automated anemia notification system that alerted providers about anemic pre-operative patients. After scheduling surgery, the alert program continuously searched the patient's laboratory data for hemoglobin value(s) in the medical record. When an anemic patient according to the World Health Oganization's criteria was identified, an email was sent to the patient's surgeon, and/or assistant, and/or patient's primary care physician suggesting that the anemia be managed before surgery. Thirteen surgeons participated in this pilot study. In 11 months, there were 70 pre-surgery anemia alerts generated on 69 patients. The surgeries were 60 orthopedic, 7 thoracic, 2 general surgery, and 1 urological. The alerts were sent 15 ± 10 days before surgery. No pre-operative anemia treatment could be found in 37 of 69 (54%) patients. Some form of anemia management was found in 32 of 69 (46%) patients. Of the 23 patients who received iron, only 3 of 23 (13%) of these patients started iron shortly after the alert was generated. The alert likely resulted in the postponement of one surgery for anemia correction. Although anemia diagnosis and management can be complex, it was hoped that receipt of the alert would lead to the management of all anemic patients. Alerts are only effective if they are received and read by a healthcare provider empowered to treat the patient or to make an appropriate referral. Automated preoperative alerts alone are not likely to alter surgeons' anemia management practices. These alerts need to be part of a comprehensive anemia management strategy.

  20. Evaluation of medication alerts in electronic health records for compliance with human factors principles

    PubMed Central

    Phansalkar, Shobha; Zachariah, Marianne; Seidling, Hanna M; Mendes, Chantal; Volk, Lynn; Bates, David W

    2014-01-01

    Introduction Increasing the adoption of electronic health records (EHRs) with integrated clinical decision support (CDS) is a key initiative of the current US healthcare administration. High over-ride rates of CDS alerts strongly limit these potential benefits. As a result, EHR designers aspire to improve alert design to achieve better acceptance rates. In this study, we evaluated drug–drug interaction (DDI) alerts generated in EHRs and compared them for compliance with human factors principles. Methods We utilized a previously validated questionnaire, the I-MeDeSA, to assess compliance with nine human factors principles of DDI alerts generated in 14 EHRs. Two reviewers independently assigned scores evaluating the human factors characteristics of each EHR. Rankings were assigned based on these scores and recommendations for appropriate alert design were derived. Results The 14 EHRs evaluated in this study received scores ranging from 8 to 18.33, with a maximum possible score of 26. Cohen's κ (κ=0.86) reflected excellent agreement among reviewers. The six vendor products tied for second and third place rankings, while the top system and bottom five systems were home-grown products. The most common weaknesses included the absence of characteristics such as alert prioritization, clear and concise alert messages indicating interacting drugs, actions for clinical management, and a statement indicating the consequences of over-riding the alert. Conclusions We provided detailed analyses of the human factors principles which were assessed and described our recommendations for effective alert design. Future studies should assess whether adherence to these recommendations can improve alert acceptance. PMID:24780721

  1. Practitioners’ Views on Computerized Drug–Drug Interaction Alerts in the VA System

    PubMed Central

    Ko, Yu; Abarca, Jacob; Malone, Daniel C.; Dare, Donna C.; Geraets, Doug; Houranieh, Antoun; Jones, William N.; Nichol, W. Paul; Schepers, Gregory P.; Wilhardt, Michelle

    2007-01-01

    Objectives To assess Veterans Affairs (VA) prescribers’ and pharmacists’ opinions about computer-generated drug–drug interaction (DDI) alerts and obtain suggestions for improving DDI alerts. Design A mail survey of 725 prescribers and 142 pharmacists from seven VA medical centers across the United States. Measurements A questionnaire asked respondents about their sources of drug and DDI information, satisfaction with the combined inpatient and outpatient computerized prescriber order entry (CPOE) system, attitude toward DDI alerts, and suggestions for improving DDI alerts. Results The overall response rate was 40% (prescribers: 36%; pharmacists: 59%). Both prescribers and pharmacists indicated that the CPOE system had a neutral to positive impact on their jobs. DDI alerts were not viewed as a waste of time and the majority (61%) of prescribers felt that DDI alerts had increased their potential to prescribe safely. However, only 30% of prescribers felt DDI alerts provided them with what they needed most of the time. Both prescribers and pharmacists agreed that DDI alerts should be accompanied by management alternatives (73% and 82%, respectively) and more detailed information (65% and 89%, respectively). When asked about suggestions for improving DDI alerts, prescribers most preferred including management options whereas pharmacists most preferred making it more difficult to override lethal interactions. Prescribers and pharmacists reported primarily relying on electronic references for general drug information (62% and 55%, respectively) and DDI information (51% and 79%, respectively). Conclusion Respondents reported neutral to positive views regarding the effect of CPOE on their jobs. Their opinions suggest DDI alerts are useful but still require additional work to increase their clinical utility. PMID:17068346

  2. 21 CFR 26.20 - Alert system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 1 2013-04-01 2013-04-01 false Alert system. 26.20 Section 26.20 Food and Drugs... PHARMACEUTICAL GOOD MANUFACTURING PRACTICE REPORTS, MEDICAL DEVICE QUALITY SYSTEM AUDIT REPORTS, AND CERTAIN... Provisions for Pharmaceutical Good Manufacturing Practices § 26.20 Alert system. (a) The details of an alert...

  3. 21 CFR 26.20 - Alert system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 1 2012-04-01 2012-04-01 false Alert system. 26.20 Section 26.20 Food and Drugs... PHARMACEUTICAL GOOD MANUFACTURING PRACTICE REPORTS, MEDICAL DEVICE QUALITY SYSTEM AUDIT REPORTS, AND CERTAIN... Provisions for Pharmaceutical Good Manufacturing Practices § 26.20 Alert system. (a) The details of an alert...

  4. 47 CFR 11.56 - EAS Participants receive CAP-formatted alerts.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false EAS Participants receive CAP-formatted alerts... SYSTEM (EAS) Emergency Operations § 11.56 EAS Participants receive CAP-formatted alerts. Notwithstanding anything herein to the contrary, all EAS Participants must be able to receive CAP-formatted EAS alerts no...

  5. 21 CFR 26.20 - Alert system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... PHARMACEUTICAL GOOD MANUFACTURING PRACTICE REPORTS, MEDICAL DEVICE QUALITY SYSTEM AUDIT REPORTS, AND CERTAIN... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Alert system. 26.20 Section 26.20 Food and Drugs... Provisions for Pharmaceutical Good Manufacturing Practices § 26.20 Alert system. (a) The details of an alert...

  6. 47 CFR 80.277 - Ship Security Alert System (SSAS).

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 5 2011-10-01 2011-10-01 false Ship Security Alert System (SSAS). 80.277... SERVICES STATIONS IN THE MARITIME SERVICES Equipment Authorization for Compulsory Ships § 80.277 Ship Security Alert System (SSAS). (a) Vessels equipped with a Ship Security Alert System pursuant to the Safety...

  7. 47 CFR 80.277 - Ship Security Alert System (SSAS).

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 5 2014-10-01 2014-10-01 false Ship Security Alert System (SSAS). 80.277... SERVICES STATIONS IN THE MARITIME SERVICES Equipment Authorization for Compulsory Ships § 80.277 Ship Security Alert System (SSAS). (a) Vessels equipped with a Ship Security Alert System pursuant to the Safety...

  8. 47 CFR 80.277 - Ship Security Alert System (SSAS).

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 5 2012-10-01 2012-10-01 false Ship Security Alert System (SSAS). 80.277... SERVICES STATIONS IN THE MARITIME SERVICES Equipment Authorization for Compulsory Ships § 80.277 Ship Security Alert System (SSAS). (a) Vessels equipped with a Ship Security Alert System pursuant to the Safety...

  9. 47 CFR 80.277 - Ship Security Alert System (SSAS).

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 5 2013-10-01 2013-10-01 false Ship Security Alert System (SSAS). 80.277... SERVICES STATIONS IN THE MARITIME SERVICES Equipment Authorization for Compulsory Ships § 80.277 Ship Security Alert System (SSAS). (a) Vessels equipped with a Ship Security Alert System pursuant to the Safety...

  10. 75 FR 25842 - Notice of a Grant With the Public Broadcasting Service

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-10

    ... development of the Commercial Mobile Alert System (CMAS), a national system to distribute emergency alert...-27 (Feb. 8, 2006) (establishing the National Alert and Tsunami Warning Program); Section 606 of the... requirements to support the distribution of geographically targeted alerts by commercial mobile service...

  11. 75 FR 26269 - Draft Programmatic Environmental Assessment for the Integrated Public Alert and Warning Program's...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-11

    ...] Draft Programmatic Environmental Assessment for the Integrated Public Alert and Warning Program's... from construction- related actions taken under the Integrated Public Alert and Warning Program (IPAWS... Order 13407, Public Alert and Warning System, by providing robust and survivable power generation, fuel...

  12. 78 FR 49292 - American Medical Alert Corporation, DBA Tunstall, Clovis, New Mexico; Amended Certification...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-13

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-82,859] American Medical Alert... Assistance on July 18, 2013, applicable to workers of American Medical Alert Corporation, doing business as... follows: All workers of American Medical Alert Corporation, doing business as Tunstall, Clovis, New Mexico...

  13. 76 FR 28789 - Draft Alert Entitled “Preventing Occupational Respiratory Disease From Dampness in Office...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-18

    ... NIOSH-238] Draft Alert Entitled ``Preventing Occupational Respiratory Disease From Dampness in Office...), announces the availability of a draft Alert entitled ``Preventing Occupational Respiratory Disease from.../niosh/docket/review/docket238/default.html . The purpose of this Alert is to provide workers and...

  14. 77 FR 28387 - Federal Advisory Committee Act; Communications Security, Reliability, and Interoperability Council

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-14

    ... practice recommendations on emergency alerting systems such as promoting E9-1-1 reliability and alerting platforms--Emergency Alert System and Common Alerting Protocol. DATES: June 6, 2012. ADDRESSES: Federal... Advisory Committee that will provide recommendations to the FCC regarding best practices and actions the...

  15. Jetliner Alert Systems

    NASA Technical Reports Server (NTRS)

    1983-01-01

    NASA research and design has significantly improved crew alert systems. The Engine Indication and Crew Alerting System (EICAS), developed by Psycho-Linguistic Research Associates, is technologically advanced and able to order alerts by priority. Ames has also developed computer controlled voice synthesizers for readouts during difficult landing approaches. This is available to airplane manufacturers.

  16. An empirical comparison of a dynamic software testability metric to static cyclomatic complexity

    NASA Technical Reports Server (NTRS)

    Voas, Jeffrey M.; Miller, Keith W.; Payne, Jeffrey E.

    1993-01-01

    This paper compares the dynamic testability prediction technique termed 'sensitivity analysis' to the static testability technique termed cyclomatic complexity. The application that we chose in this empirical study is a CASE generated version of a B-737 autoland system. For the B-737 system we analyzed, we isolated those functions that we predict are more prone to hide errors during system/reliability testing. We also analyzed the code with several other well-known static metrics. This paper compares and contrasts the results of sensitivity analysis to the results of the static metrics.

  17. Sawja: Static Analysis Workshop for Java

    NASA Astrophysics Data System (ADS)

    Hubert, Laurent; Barré, Nicolas; Besson, Frédéric; Demange, Delphine; Jensen, Thomas; Monfort, Vincent; Pichardie, David; Turpin, Tiphaine

    Static analysis is a powerful technique for automatic verification of programs but raises major engineering challenges when developing a full-fledged analyzer for a realistic language such as Java. Efficiency and precision of such a tool rely partly on low level components which only depend on the syntactic structure of the language and therefore should not be redesigned for each implementation of a new static analysis. This paper describes the Sawja library: a static analysis workshop fully compliant with Java 6 which provides OCaml modules for efficiently manipulating Java bytecode programs. We present the main features of the library, including i) efficient functional data-structures for representing a program with implicit sharing and lazy parsing, ii) an intermediate stack-less representation, and iii) fast computation and manipulation of complete programs. We provide experimental evaluations of the different features with respect to time, memory and precision.

  18. Alert Exchange Process Protocol

    NASA Technical Reports Server (NTRS)

    Groen, Frank

    2015-01-01

    The National Aeronautics and Space Administration of the United States of America (NASA), and the European Space Agency (ESA), and the Japanese Aerospace Exploration Agency (JAXA), acknowledging that NASA, ESA and JAXA have a mutual interest in exchanging Alerts and Alert Status Lists to enhance the information base for each system participant while fortifying the general level of cooperation between the policy agreement subscribers, and each Party will exchange Alert listings on regular basis and detailed Alert information on a need to know basis to the extent permitted by law.

  19. Evaluation of a National Call Center and a Local Alerts System for Detection of New Cases of Ebola Virus Disease - Guinea, 2014-2015

    DTIC Science & Technology

    2016-03-11

    Control and Prevention Evaluation of a National Call Center and a Local Alerts System for Detection of New Cases of Ebola Virus Disease — Guinea, 2014...principally through the use of a telephone alert system. Community members and health facilities report deaths and suspected Ebola cases to local alert ...sensitivity of the national call center with the local alerts system, the CDC country team performed probabilistic record linkage of the combined

  20. Effect of Ankle Range of Motion (ROM) and Lower-Extremity Muscle Strength on Static Balance Control Ability in Young Adults: A Regression Analysis

    PubMed Central

    Kim, Seong-Gil

    2018-01-01

    Background The purpose of this study was to investigate the effect of ankle ROM and lower-extremity muscle strength on static balance control ability in young adults. Material/Methods This study was conducted with 65 young adults, but 10 young adults dropped out during the measurement, so 55 young adults (male: 19, female: 36) completed the study. Postural sway (length and velocity) was measured with eyes open and closed, and ankle ROM (AROM and PROM of dorsiflexion and plantarflexion) and lower-extremity muscle strength (flexor and extensor of hip, knee, and ankle joint) were measured. Pearson correlation coefficient was used to examine the correlation between variables and static balance ability. Simple linear regression analysis and multiple linear regression analysis were used to examine the effect of variables on static balance ability. Results In correlation analysis, plantarflexion ROM (AROM and PROM) and lower-extremity muscle strength (except hip extensor) were significantly correlated with postural sway (p<0.05). In simple correlation analysis, all variables that passed the correlation analysis procedure had significant influence (p<0.05). In multiple linear regression analysis, plantar flexion PROM with eyes open significantly influenced sway length (B=0.681) and sway velocity (B=0.011). Conclusions Lower-extremity muscle strength and ankle plantarflexion ROM influenced static balance control ability, with ankle plantarflexion PROM showing the greatest influence. Therefore, both contractile structures and non-contractile structures should be of interest when considering static balance control ability improvement. PMID:29760375

  1. Effect of Ankle Range of Motion (ROM) and Lower-Extremity Muscle Strength on Static Balance Control Ability in Young Adults: A Regression Analysis.

    PubMed

    Kim, Seong-Gil; Kim, Wan-Soo

    2018-05-15

    BACKGROUND The purpose of this study was to investigate the effect of ankle ROM and lower-extremity muscle strength on static balance control ability in young adults. MATERIAL AND METHODS This study was conducted with 65 young adults, but 10 young adults dropped out during the measurement, so 55 young adults (male: 19, female: 36) completed the study. Postural sway (length and velocity) was measured with eyes open and closed, and ankle ROM (AROM and PROM of dorsiflexion and plantarflexion) and lower-extremity muscle strength (flexor and extensor of hip, knee, and ankle joint) were measured. Pearson correlation coefficient was used to examine the correlation between variables and static balance ability. Simple linear regression analysis and multiple linear regression analysis were used to examine the effect of variables on static balance ability. RESULTS In correlation analysis, plantarflexion ROM (AROM and PROM) and lower-extremity muscle strength (except hip extensor) were significantly correlated with postural sway (p<0.05). In simple correlation analysis, all variables that passed the correlation analysis procedure had significant influence (p<0.05). In multiple linear regression analysis, plantar flexion PROM with eyes open significantly influenced sway length (B=0.681) and sway velocity (B=0.011). CONCLUSIONS Lower-extremity muscle strength and ankle plantarflexion ROM influenced static balance control ability, with ankle plantarflexion PROM showing the greatest influence. Therefore, both contractile structures and non-contractile structures should be of interest when considering static balance control ability improvement.

  2. Effects of cognitive appraisal and mental workload factors on performance in an arithmetic task.

    PubMed

    Galy, Edith; Mélan, Claudine

    2015-12-01

    We showed in a previous study an additive interaction between intrinsic and extraneous cognitive loads and of participants' alertness in an 1-back working memory task. The interaction between intrinsic and extraneous cognitive loads was only observed when participants' alertness was low (i.e. in the morning). As alertness is known to reflect an individual's general functional state, we suggested that the working memory capacity available for germane cognitive load depends on a participant's functional state, in addition to intrinsic and extraneous loads induced by the task and task conditions. The relationships between the different load types and their assessment by specific load measures gave rise to a modified cognitive load model. The aim of the present study was to complete the model by determining to what extent and at what processing level an individual's characteristics intervene in order to implement efficient strategies in a working memory task. Therefore, the study explored participants' cognitive appraisal of the situation in addition to the load factors considered previously-task difficulty, time pressure and alertness. Each participant performed a mental arithmetic task in four different cognitive load conditions (crossover of two task difficulty conditions and of two time pressure conditions), both while their alertness was low (9 a.m.) and high (4 p.m.). Results confirmed an additive effect of task difficulty and time pressure, previously reported in the 1-back memory task, thereby lending further support to the modified cognitive load model. Further, in the high intrinsic and extraneous load condition, performance was reduced on the morning session (i.e. when alertness was low) on one hand, and in those participants' having a threat appraisal of the situation on the other hand. When these factors were included into the analysis, a performance drop occurred in the morning irrespective of cognitive appraisal, and with threat appraisal in the afternoon (i.e. high alertness). Taken together, these findings indicate that mental overload can be the result of a combination of subject-related characteristics, including alertness and cognitive appraisal, in addition to well-documented task-related components (intrinsic and extraneous load). As the factors investigated in the study are known to be critically involved in a number of real job-activities, the findings suggest that solutions designed to reduce incidents and accidents at work should consider the situation from a global perspective, including individual characteristics, task parameters, and work organization, rather than dealing with each factor separately.

  3. Using electronic health record alerts to provide public health situational awareness to clinicians.

    PubMed

    Lurio, Joseph; Morrison, Frances P; Pichardo, Michelle; Berg, Rachel; Buck, Michael D; Wu, Winfred; Kitson, Kwame; Mostashari, Farzad; Calman, Neil

    2010-01-01

    Alerting providers to public health situations requires timeliness and context-relevance, both lacking in current systems. Incorporating decision support tools into electronic health records may provide a way to deploy public health alerts to clinicians at the point of care. A timely process for responding to Health Alert Network messages sent by the New York City Department of Health and Mental Hygiene was developed by a network of community health centers. Alerts with order sets and recommended actions were created to notify primary care providers of local disease outbreaks. The process, effect, and lessons learned from alerts for Legionella, toxogenic E coli, and measles outbreaks are described. Electronic alerts have the potential to improve management of diseases during an outbreak, including appropriate laboratory testing, management guidance, and diagnostic assistance as well as to enhance bi-directional data exchange between clinical and public health organizations.

  4. Using electronic health record alerts to provide public health situational awareness to clinicians

    PubMed Central

    Lurio, Joseph; Pichardo, Michelle; Berg, Rachel; Buck, Michael D; Wu, Winfred; Kitson, Kwame; Mostashari, Farzad; Calman, Neil

    2010-01-01

    Alerting providers to public health situations requires timeliness and context-relevance, both lacking in current systems. Incorporating decision support tools into electronic health records may provide a way to deploy public health alerts to clinicians at the point of care. A timely process for responding to Health Alert Network messages sent by the New York City Department of Health and Mental Hygiene was developed by a network of community health centers. Alerts with order sets and recommended actions were created to notify primary care providers of local disease outbreaks. The process, effect, and lessons learned from alerts for Legionella, toxogenic E coli, and measles outbreaks are described. Electronic alerts have the potential to improve management of diseases during an outbreak, including appropriate laboratory testing, management guidance, and diagnostic assistance as well as to enhance bi-directional data exchange between clinical and public health organizations. PMID:20190067

  5. Computerized Alerts Improve Outpatient Laboratory Monitoring of Transplant Patients

    PubMed Central

    Staes, Catherine J.; Evans, R. Scott; Rocha, Beatriz H.S.C.; Sorensen, John B.; Huff, Stanley M.; Arata, Joan; Narus, Scott P.

    2008-01-01

    Authors evaluated the impact of computerized alerts on the quality of outpatient laboratory monitoring for transplant patients. For 356 outpatient liver transplant patients managed at LDS Hospital, Salt Lake City, this observational study compared traditional laboratory result reporting, using faxes and printouts, to computerized alerts implemented in 2004. Study alerts within the electronic health record notified clinicians of new results and overdue new orders for creatinine tests and immunosuppression drug levels. After implementing alerts, completeness of reporting increased from 66 to >99 %, as did positive predictive value that a report included new information (from 46 to >99 %). Timeliness of reporting and clinicians' responses improved after implementing alerts (p <0.001): median times for clinicians to receive and complete actions decreased to 9 hours from 33 hours using the prior traditional reporting system. Computerized alerts led to more efficient, complete, and timely management of laboratory information. PMID:18308982

  6. THE DETECTION OF A SN IIn IN OPTICAL FOLLOW-UP OBSERVATIONS OF ICECUBE NEUTRINO EVENTS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aartsen, M. G.; Abraham, K.; Ackermann, M.

    2015-09-20

    The IceCube neutrino observatory pursues a follow-up program selecting interesting neutrino events in real-time and issuing alerts for electromagnetic follow-up observations. In 2012 March, the most significant neutrino alert during the first three years of operation was issued by IceCube. In the follow-up observations performed by the Palomar Transient Factory (PTF), a Type IIn supernova (SN IIn) PTF12csy was found 0.°2 away from the neutrino alert direction, with an error radius of 0.°54. It has a redshift of z = 0.0684, corresponding to a luminosity distance of about 300 Mpc and the Pan-STARRS1 survey shows that its explosion time wasmore » at least 158 days (in host galaxy rest frame) before the neutrino alert, so that a causal connection is unlikely. The a posteriori significance of the chance detection of both the neutrinos and the SN at any epoch is 2.2σ within IceCube's 2011/12 data acquisition season. Also, a complementary neutrino analysis reveals no long-term signal over the course of one year. Therefore, we consider the SN detection coincidental and the neutrinos uncorrelated to the SN. However, the SN is unusual and interesting by itself: it is luminous and energetic, bearing strong resemblance to the SN IIn 2010jl, and shows signs of interaction of the SN ejecta with a dense circumstellar medium. High-energy neutrino emission is expected in models of diffusive shock acceleration, but at a low, non-detectable level for this specific SN. In this paper, we describe the SN PTF12csy and present both the neutrino and electromagnetic data, as well as their analysis.« less

  7. Alerts in electronic medical records to promote a colorectal cancer screening programme: a cluster randomised controlled trial in primary care.

    PubMed

    Guiriguet, Carolina; Muñoz-Ortiz, Laura; Burón, Andrea; Rivero, Irene; Grau, Jaume; Vela-Vallespín, Carmen; Vilarrubí, Mercedes; Torres, Miquel; Hernández, Cristina; Méndez-Boo, Leonardo; Toràn, Pere; Caballeria, Llorenç; Macià, Francesc; Castells, Antoni

    2016-07-01

    Participation rates in colorectal cancer screening are below recommended European targets. To evaluate the effectiveness of an alert in primary care electronic medical records (EMRs) to increase individuals' participation in an organised, population-based colorectal cancer screening programme when compared with usual care. Cluster randomised controlled trial in primary care centres of Barcelona, Spain. Participants were males and females aged 50-69 years, who were invited to the first round of a screening programme based on the faecal immunochemical test (FIT) (n = 41 042), and their primary care professional. The randomisation unit was the physician cluster (n = 130) and patients were blinded to the study group. The control group followed usual care as per the colorectal cancer screening programme. In the intervention group, as well as usual care, an alert to health professionals (cluster level) to promote screening was introduced in the individual's primary care EMR for 1 year. The main outcome was colorectal cancer screening participation at individual participant level. In total, 67 physicians and 21 619 patients (intervention group) and 63 physicians and 19 423 patients (control group) were randomised. In the intention-to-treat analysis screening participation was 44.1% and 42.2% respectively (odds ratio 1.08, 95% confidence interval [CI] = 0.97 to 1.20, P = 0.146). However, in the per-protocol analysis screening uptake in the intervention group showed a statistically significant increase, after adjusting for potential confounders (OR, 1.11; 95% CI = 1.02 to 1.22; P = 0.018). The use of an alert in an individual's primary care EMR is associated with a statistically significant increased uptake of an organised, FIT-based colorectal cancer screening programme in patients attending primary care centres. © British Journal of General Practice 2016.

  8. Self-Alert Training: Volitional Modulation of Autonomic Arousal Improves Sustained Attention

    ERIC Educational Resources Information Center

    O'Connell, Redmond G.; Bellgrove, Mark A.; Dockree, Paul M.; Lau, Adam; Fitzgerald, Michael; Robertson, Ian H.

    2008-01-01

    The present study examines a new alertness training strategy (Self-Alert Training, SAT) designed to explore the relationship between the top-down control processes governing arousal and sustained attention. In order to maximally target frontal control systems SAT combines a previously validated behavioural self-alerting technique [Robertson, I.…

  9. 75 FR 2105 - Publication of OIG Updated Special Fraud Alert on Telemarketing by Durable Medical Equipment...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-14

    ... Inspector General Publication of OIG Updated Special Fraud Alert on Telemarketing by Durable Medical... Register notice sets forth the recently issued OIG Updated Special Fraud Alert addressing telemarketing by durable medical equipment (DME) suppliers. For the most part, OIG Special Fraud Alerts address national...

  10. 76 FR 81904 - Solicitation of New Safe Harbors and Special Fraud Alerts

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-29

    ... of New Safe Harbors and Special Fraud Alerts AGENCY: Office of Inspector General (OIG), HHS. ACTION... Special Fraud Alerts. DATES: To assure consideration, public comments must be delivered to the address... and Special Fraud Alerts. Please assist us by referencing the file code OIG-120-N. Inspection of...

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Connell, Leonard W.; Edenburn, Michael W.; Fraley, Stanley K.

    This paper presents a framework for evaluating the technical merits of strategic ballistic missile de-alerting measures, and it uses the framework to evaluate a variety of possible measures for silo-based, land-mobile, and submarine-based missiles. De-alerting measures are defined for the purpose of this paper as reversible actions taken to increase the time or effort required to launch a strategic ballistic missile. The paper does not assess the desirability of pursuing a de-alerting program. Such an assessment is highly context dependent. The paper postulates that if de-alerting is desirable and is used as an arms control mechanism, de-alerting measures should satisfymore » specific cirteria relating to force security, practicality, effectiveness, significant delay, and verifiability. Silo-launched missiles lend themselves most readily to de-alerting verification, because communications necessary for monitoring do not increase the vulnerabilty of the weapons by a significant amount. Land-mobile missile de-alerting measures would be more challenging to verify, because monitoring measures that disclose the launcher's location would potentially increase their vulnerability. Submarine-launched missile de-alerting measures would be extremely challlenging if not impossible to monitor without increasing the submarine's vulnerability.« less

  12. The Impact of Alerting Designs on Air Traffic Controller's Eye Movement Patterns and Situation Awareness.

    PubMed

    Kearney, Peter; Li, Wen-Chin; Yu, Chung-San; Braithwaite, Graham

    2018-06-26

    This research investigated controller' situation awareness by comparing COOPANS's acoustic alerts with newly designed semantic alerts. The results demonstrate that ATCOs' visual scan patterns had significant differences between acoustic and semantic designs. ATCOs established different eye movement patterns on fixations number, fixation duration and saccade velocity. Effective decision support systems require human-centred design with effective stimuli to direct ATCO's attention to critical events. It is necessary to provide ATCOs with specific alerting information to reflect the nature of of the critical situation in order to minimize the side-effects of startle and inattentional deafness. Consequently, the design of a semantic alert can significantly reduce ATCOs' response time, therefore providing valuable extra time in a time-limited situation to formulate and execute resolution strategies in critical air safety events. The findings of this research indicate that the context-specified design of semantic alerts could improve ATCO's situational awareness and significantly reduce response time in the event of Short Term Conflict Alert activation which alerts to two aircraft having less than the required lateral or vertical separation.

  13. Description of the AILS Alerting Algorithm

    NASA Technical Reports Server (NTRS)

    Samanant, Paul; Jackson, Mike

    2000-01-01

    This document provides a complete description of the Airborne Information for Lateral Spacing (AILS) alerting algorithms. The purpose of AILS is to provide separation assurance between aircraft during simultaneous approaches to closely spaced parallel runways. AILS will allow independent approaches to be flown in such situations where dependent approaches were previously required (typically under Instrument Meteorological Conditions (IMC)). This is achieved by providing multiple levels of alerting for pairs of aircraft that are in parallel approach situations. This document#s scope is comprehensive and covers everything from general overviews, definitions, and concepts down to algorithmic elements and equations. The entire algorithm is presented in complete and detailed pseudo-code format. This can be used by software programmers to program AILS into a software language. Additional supporting information is provided in the form of coordinate frame definitions, data requirements, calling requirements as well as all necessary pre-processing and post-processing requirements. This is important and required information for the implementation of AILS into an analysis, a simulation, or a real-time system.

  14. Prevalence of L. Monocytogenes in Environmental Samples Collected in Dairy Plants of Sassari Province, Italy

    PubMed Central

    Fadda, Antonio; Frongia, Giorgio; Sanna, Antonietta; Melillo, Rita

    2015-01-01

    Listeria (L.) monocytogenes is frequently isolated from food production environment and often persists in dairy plants despite vigorous sanitation regimes. In recent years several alert notifications were sent to Rapid Alert System for Food Products system as a consequence of Listeria monocytogenes contamination of ricotta cheese. After the alert of 2012, competent authority (Local Health Unit of Sassari Province) organised an environmental monitoring plan with the partnership of the Institute for Experimental Veterinary Medicine of Sardinia to verify analysis of dairy plants own-check according to Regulation (EC) N° 2073/05 and further modifications. In 2014 n. 665 processing areas samples of n. 50 dairy plants of Sassari Province were examined. UNI EN ISO 11290-1:2005 for detection of L. monocytogenes was used. Non-compliance in n. 5 diary plants are observed (n. 8 positive samples). Post-non-compliance environmental sanitisation was efficient and own-check plans included appropriate corrective actions. PMID:27800407

  15. Flight crew interface aspects of forward-looking airborne windshear detection systems

    NASA Technical Reports Server (NTRS)

    Anderson, Charles D.; Carbaugh, David C.

    1993-01-01

    The goal of this research effort was to conduct analyses and research which could provide guidelines for design of the crew interface of an integrated windshear system. Addressed were HF issues, crew/system requirements, candidate display formats, alerting criteria, and crew procedures. A survey identified five flight management issues as top priority: missed alert acceptability; avoidance distance needed; false alert acceptability; nuisance rate acceptability; and crew procedures. Results of a simulation study indicated that the warning time for a look-ahead alert needs to be between 11 and 36 seconds (target of 23 seconds) before the reactive system triggers in order to be effective. Pilots considered the standard go-around maneuver most appropriate for look-ahead alerts, and the escape maneuvers used did not require lateral turns. Prototype display formats were reviewed or developed for alerting the crew; providing guidance to avoid or escape windshear; and status displays to provide windshear situational awareness. The three alerting levels now in use were considered appropriate, with a fourth (time-critical) level as a possible addition, although many reviewers felt only two levels of alerting were needed. Another survey gathered expert opinion on what crew procedures and alerting criteria should be used for look-ahead, or integrated, windshear systems, with a wide diversity of opinion in these areas.

  16. Dual-task performance consequences of imperfect alerting associated with a cockpit display of traffic information.

    PubMed

    Wickens, Christopher; Colcombe, Angela

    2007-10-01

    Performance consequences related to integrating an imperfect alert within a complex task domain were examined in two experiments. Cockpit displays of traffic information (CDTIs) are being designed for use in airplane cockpits as responsibility for safe separation becomes shared between pilots and controllers. Of interest in this work is how characteristics of the alarm system such as threshold, modality, and number of alert levels impact concurrent task (flight control) performance and response to potential conflicts. Student pilots performed a tracking task analogous to flight control while simultaneously monitoring for air traffic conflicts with the aid of a CDTI alert as the threshold, modality, and level of alert was varied. As the alerting system became more prone to false alerts, pilot compliance decreased and concurrent performance improved. There was some evidence of auditory preemption with auditory alerts as the false alarm rate increased. Finally, there was no benefit to a three-level system over a two-level system. There is justification for increased false alarm rates, as miss-prone systems appear to be costly. The 4:1 false alarm to miss ratio employed here improved accuracy and concurrent task performance. More research needs to address the potential benefits of likelihood alerting. The issues addressed in this research can be applied to any imperfect alerting system such as in aviation, driving, or air traffic control. It is crucial to understand the performance consequences of new technology and the efficacy of potential mitigating design features within the specific context desired.

  17. Structural Analysis Peer Review for the Static Display of the Orbiter Atlantis at the Kennedy Space Center Visitors Center

    NASA Technical Reports Server (NTRS)

    Minute, Stephen A.

    2013-01-01

    Mr. Christopher Miller with the Kennedy Space Center (KSC) NASA Safety & Mission Assurance (S&MA) office requested the NASA Engineering and Safety Center's (NESC) technical support on March 15, 2012, to review and make recommendations on the structural analysis being performed for the Orbiter Atlantis static display at the KSC Visitor Center. The principal focus of the assessment was to review the engineering firm's structural analysis for lifting and aligning the orbiter and its static display configuration

  18. Parametric optimization and design validation based on finite element analysis of hybrid socket adapter for transfemoral prosthetic knee.

    PubMed

    Kumar, Neelesh

    2014-10-01

    Finite element analysis has been universally employed for the stress and strain analysis in lower extremity prosthetics. The socket adapter was the principal subject of interest due to its importance in deciding the knee motion range. This article focused on the static and dynamic stress analysis of the designed hybrid adapter developed by the authors. A standard mechanical design validation approach using von Mises was followed. Four materials were considered for the analysis, namely, carbon fiber, oil-filled nylon, Al-6061, and mild steel. The paper analyses the static and dynamic stress on designed hybrid adapter which incorporates features of conventional male and female socket adapters. The finite element analysis was carried out for possible different angles of knee flexion simulating static and dynamic gait situation. Research was carried out on available design of socket adapter. Mechanical design of hybrid adapter was conceptualized and a CAD model was generated using Inventor modelling software. Static and dynamic stress analysis was carried out on different materials for optimization. The finite element analysis was carried out on the software Autodesk Inventor Professional Ver. 2011. The peak value of von Mises stress occurred in the neck region of the adapter and in the lower face region at rod eye-adapter junction in static and dynamic analyses, respectively. Oil-filled nylon was found to be the best material among the four with respect to strength, weight, and cost. Research investigations on newer materials for development of improved prosthesis will immensely benefit the amputees. The study analyze the static and dynamic stress on the knee joint adapter to provide better material used for hybrid design of adapter. © The International Society for Prosthetics and Orthotics 2013.

  19. Validation of Test Performance and Clinical Time Zero for an Electronic Health Record Embedded Severe Sepsis Alert

    PubMed Central

    Downing, N. Lance; Shepard, John; Chu, Weihan; Tam, Julia; Wessels, Alexander; Li, Ron; Dietrich, Brian; Rudy, Michael; Castaneda, Leon; Shieh, Lisa

    2016-01-01

    Summary Bachground Increasing use of EHRs has generated interest in the potential of computerized clinical decision support to improve treatment of sepsis. Electronic sepsis alerts have had mixed results due to poor test characteristics, the inability to detect sepsis in a timely fashion and the use of outside software limiting widespread adoption. We describe the development, evaluation and validation of an accurate and timely severe sepsis alert with the potential to impact sepsis management. Objective To develop, evaluate, and validate an accurate and timely severe sepsis alert embedded in a commercial EHR. Methods The sepsis alert was developed by identifying the most common severe sepsis criteria among a cohort of patients with ICD 9 codes indicating a diagnosis of sepsis. This alert requires criteria in three categories: indicators of a systemic inflammatory response, evidence of suspected infection from physician orders, and markers of organ dysfunction. Chart review was used to evaluate test performance and the ability to detect clinical time zero, the point in time when a patient develops severe sepsis. Results Two physicians reviewed 100 positive cases and 75 negative cases. Based on this review, sensitivity was 74.5%, specificity was 86.0%, the positive predictive value was 50.3%, and the negative predictive value was 94.7%. The most common source of end-organ dysfunction was MAP less than 70 mm/Hg (59%). The alert was triggered at clinical time zero in 41% of cases and within three hours in 53.6% of cases. 96% of alerts triggered before a manual nurse screen. Conclusion We are the first to report the time between a sepsis alert and physician chart-review clinical time zero. Incorporating physician orders in the alert criteria improves specificity while maintaining sensitivity, which is important to reduce alert fatigue. By leveraging standard EHR functionality, this alert could be implemented by other healthcare systems. PMID:27437061

  20. Validation of Test Performance and Clinical Time Zero for an Electronic Health Record Embedded Severe Sepsis Alert.

    PubMed

    Rolnick, Joshua; Downing, N Lance; Shepard, John; Chu, Weihan; Tam, Julia; Wessels, Alexander; Li, Ron; Dietrich, Brian; Rudy, Michael; Castaneda, Leon; Shieh, Lisa

    2016-01-01

    Increasing use of EHRs has generated interest in the potential of computerized clinical decision support to improve treatment of sepsis. Electronic sepsis alerts have had mixed results due to poor test characteristics, the inability to detect sepsis in a timely fashion and the use of outside software limiting widespread adoption. We describe the development, evaluation and validation of an accurate and timely severe sepsis alert with the potential to impact sepsis management. To develop, evaluate, and validate an accurate and timely severe sepsis alert embedded in a commercial EHR. The sepsis alert was developed by identifying the most common severe sepsis criteria among a cohort of patients with ICD 9 codes indicating a diagnosis of sepsis. This alert requires criteria in three categories: indicators of a systemic inflammatory response, evidence of suspected infection from physician orders, and markers of organ dysfunction. Chart review was used to evaluate test performance and the ability to detect clinical time zero, the point in time when a patient develops severe sepsis. Two physicians reviewed 100 positive cases and 75 negative cases. Based on this review, sensitivity was 74.5%, specificity was 86.0%, the positive predictive value was 50.3%, and the negative predictive value was 94.7%. The most common source of end-organ dysfunction was MAP less than 70 mm/Hg (59%). The alert was triggered at clinical time zero in 41% of cases and within three hours in 53.6% of cases. 96% of alerts triggered before a manual nurse screen. We are the first to report the time between a sepsis alert and physician chart-review clinical time zero. Incorporating physician orders in the alert criteria improves specificity while maintaining sensitivity, which is important to reduce alert fatigue. By leveraging standard EHR functionality, this alert could be implemented by other healthcare systems.

  1. Improving Recognition of Pediatric Severe Sepsis in the Emergency Department: Contributions of a Vital Sign-Based Electronic Alert and Bedside Clinician Identification.

    PubMed

    Balamuth, Fran; Alpern, Elizabeth R; Abbadessa, Mary Kate; Hayes, Katie; Schast, Aileen; Lavelle, Jane; Fitzgerald, Julie C; Weiss, Scott L; Zorc, Joseph J

    2017-12-01

    Recognition of pediatric sepsis is a key clinical challenge. We evaluate the performance of a sepsis recognition process including an electronic sepsis alert and bedside assessment in a pediatric emergency department (ED). This was a cohort study with quality improvement intervention in a pediatric ED. Exposure was a positive electronic sepsis alert, defined as elevated pulse rate or hypotension, concern for infection, and at least one of the following: abnormal capillary refill, abnormal mental status, or high-risk condition. A positive electronic sepsis alert prompted team assessment or huddle to determine need for sepsis protocol. Clinicians could initiate team assessment or huddle according to clinical concern without positive electronic sepsis alert. Severe sepsis outcome defined as activation of the sepsis protocol in the ED or development of severe sepsis requiring ICU admission within 24 hours. There were 182,509 ED visits during the study period, with 86,037 before electronic sepsis alert implementation and 96,472 afterward, and 1,112 (1.2%) positive electronic sepsis alerts. Overall, 326 patients (0.3%) were treated for severe sepsis within 24 hours. Test characteristics of the electronic sepsis alert alone to detect severe sepsis were sensitivity 86.2% (95% confidence interval [CI] 82.0% to 89.5%), specificity 99.1% (95% CI 99.0% to 99.2%), positive predictive value 25.4% (95% CI 22.8% to 28.0%), and negative predictive value 100% (95% CI 99.9% to 100%). Inclusion of the clinician screen identified 43 additional electronic sepsis alert-negative children, with severe sepsis sensitivity 99.4% (95% CI 97.8% to 99.8%) and specificity 99.1% (95% CI 99.1% to 99.2%). Electronic sepsis alert implementation increased ED sepsis detection from 83% to 96%. Electronic sepsis alert for severe sepsis demonstrated good sensitivity and high specificity. Addition of clinician identification of electronic sepsis alert-negative patients further improved sensitivity. Implementation of the electronic sepsis alert was associated with improved recognition of severe sepsis. Copyright © 2017 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

  2. LEWICE3D/GlennHT Particle Analysis of the Honeywell Al502 Low Pressure Compressor

    NASA Technical Reports Server (NTRS)

    Bidwell, Colin S.; Rigby, David L.

    2015-01-01

    A flow and ice particle trajectory analysis was performed for the booster of the Honeywell AL502 engine. The analysis focused on two closely related conditions one of which produced a rollback and another which did not rollback during testing in the Propulsion Systems Lab at NASA Glenn Research Center. The flow analysis was generated using the NASA Glenn GlennHT flow solver and the particle analysis was generated using the NASA Glenn LEWICE3D v3.56 ice accretion software. The flow and particle analysis used a 3D steady flow, mixing plane approach to model the transport of flow and particles through the engine. The inflow conditions for the rollback case were: airspeed, 145 ms; static pressure, 33,373 Pa; static temperature, 253.3 K. The inflow conditions for the non-roll-back case were: airspeed, 153 ms; static pressure, 34,252 Pa; static temperature, 260.1 K. Both cases were subjected to an ice particle cloud with a median volume diameter of 24 microns, an ice water content of 2.0 gm3 and a relative humidity of 100 percent. The most significant difference between the rollback and non-rollback conditions was the inflow static temperature which was 6.8 K higher for the non-rollback case.

  3. Flood warnings in coastal areas: how do social and behavioural patterns influence alert services?

    NASA Astrophysics Data System (ADS)

    Pescaroli, G.; Magni, M.

    2015-01-01

    Many studies discuss the economic and technical aspects of flood warnings. Less attention has been given to the social and psychological patterns that affect alert services. In particular, the literature focuses on warnings activated in river basins or marine environments without providing clear evidence of relevance to Mediterranean coastal areas, even though these are subjected to growing flood risk related to climate change. This paper is a first attempt to bridge this gap. Our research develops an in- depth analysis of the village of Cesenatico on the Adriatic Sea coast. Here the municipality adopted two complementary warning systems: a siren and an alert via Short Message Service (SMS). The analysis focuses on a survey conducted in 2011 and 2012 with 228 participants. The relationships between social and behavioural variables and warning services are investigated, and so are flood preparedness and information dissemination. Qualitative evidence from informal interviews is used to support the understanding of key responses. The conclusions show how different social and behavioural patterns can influence the effectiveness and use of warning systems, regardless of the technology adopted and the structural mitigation measures implemented. Education, training and accountability are seen to be critical elements for improvement. Finally, the statistical output is used to suggest new questions and new directions for research.

  4. Flood warnings in coastal areas: how do experience and information influence responses to alert services?

    NASA Astrophysics Data System (ADS)

    Pescaroli, G.; Magni, M.

    2015-04-01

    Many studies discuss the economic and technical aspects of flood warnings. Less attention has been given to the social and behavioural patterns that affect alert services. In particular, the literature focuses on warnings activated in river basins or marine environments without providing clear evidence on Mediterranean coastal areas, even though these are subjected to growing flood risk related to climate change. This paper is a first attempt to bridge this gap. Our research develops an in-depth analysis of the village of Cesenatico on the Adriatic Sea coast. Here the municipality adopted two complementary warning systems: a siren and an alert via short message service (SMS). The analysis focuses on a survey conducted in 2011 and 2012 with 228 participants. The relationships between social and behavioural variables and warning services are investigated as well as flood preparedness and information dissemination. Qualitative evidence from informal interviews is used to support the understanding of key responses. The conclusions show how different social and behavioural patterns can influence the effectiveness and use of warning systems, regardless of the technology adopted and the structural mitigation measures implemented. Education, training and accountability are seen to be critical elements for implementation. Finally, the statistical output is used to suggest new questions and new directions for research.

  5. The potential role of real-time geodetic observations in tsunami early warning

    NASA Astrophysics Data System (ADS)

    Tinti, Stefano; Armigliato, Alberto

    2016-04-01

    Tsunami warning systems (TWS) have the final goal to launch a reliable alert of an incoming dangerous tsunami to coastal population early enough to allow people to flee from the shore and coastal areas according to some evacuation plans. In the last decade, especially after the catastrophic 2004 Boxing Day tsunami in the Indian Ocean, much attention has been given to filling gaps in the existing TWSs (only covering the Pacific Ocean at that time) and to establishing new TWSs in ocean regions that were uncovered. Typically, TWSs operating today work only on earthquake-induced tsunamis. TWSs estimate quickly earthquake location and size by real-time processing seismic signals; on the basis of some pre-defined "static" procedures (either based on decision matrices or on pre-archived tsunami simulations), assess the tsunami alert level on a large regional scale and issue specific bulletins to a pre-selected recipients audience. Not unfrequently these procedures result in generic alert messages with little value. What usually operative TWSs do not do, is to compute earthquake focal mechanism, to calculate the co-seismic sea-floor displacement, to assess the initial tsunami conditions, to input these data into tsunami simulation models and to compute tsunami propagation up to the threatened coastal districts. This series of steps is considered nowadays too time consuming to provide the required timely alert. An equivalent series of steps could start from the same premises (earthquake focal parameters) and reach the same result (tsunami height at target coastal areas) by replacing the intermediate steps of real-time tsunami simulations with proper selection from a large archive of pre-computed tsunami scenarios. The advantage of real-time simulations and of archived scenarios selection is that estimates are tailored to the specific occurring tsunami and alert can be more detailed (less generic) and appropriate for local needs. Both these procedures are still at an experimental or testing stage and haven't been implemented yet in any standard TWS operations. Nonetheless, this is seen to be the future and the natural TWS evolving enhancement. In this context, improvement of the real-time estimates of tsunamigenic earthquake focal mechanism is of fundamental importance to trigger the appropriate computational chain. Quick discrimination between strike-slip and thrust-fault earthquakes, and equally relevant, quick assessment of co-seismic on-fault slip distribution, are exemplary cases to which a real-time geodetic monitoring system can contribute significantly. Robust inversion of geodetic data can help to reconstruct the sea floor deformation pattern especially if two conditions are met: the source is not too far from network stations and is well covered azimuthally. These two conditions are sometimes hard to satisfy fully, but in certain regions, like the Mediterranean and the Caribbean sea, this is quite possible due to the limited size of the ocean basins. Close cooperation between the Global Geodetic Observing System (GGOS) community, seismologists, tsunami scientists and TWS operators is highly recommended to obtain significant progresses in the quick determination of the earthquake source, which can trigger a timely estimation of the ensuing tsunami and a more reliable and detailed assessment of the tsunami size at the coast.

  6. Learning Enterprise Malware Triage from Automatic Dynamic Analysis

    DTIC Science & Technology

    2013-03-01

    Kolter and Maloof n-gram method, Dube’s malware target recognition (MaTR) static method performs significantly more accurately at the 95% confidence...from the static method as in Kolter and Maloof. The MIST approach with behavior sequences 9 allows researchers to tailor the level of analysis to the...citations, none publish work that implements it. Only Kolter and Maloof use nearly as long gram structures, although that research uses static grams rather

  7. Experimental evaluation of candidate graphical microburst alert displays

    NASA Technical Reports Server (NTRS)

    Wanke, Craig; Hansman, R. John

    1992-01-01

    The topics addressed are: (1) experimental evaluation of candidate graphical microburst displays; (2) microburst detection and alerting; (3) previous part-task simulator experiment-comparison of presentation modes; (4) presentation mode comparison-results; (5) advantages of graphical mode of presentation; (6) graphical microburst alert experiment-objectives; and graphical microburst alert experiment-overview; and (7) candidate display design.

  8. 78 FR 78807 - Solicitation of New Safe Harbors and Special Fraud Alerts

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-27

    ... of New Safe Harbors and Special Fraud Alerts AGENCY: Office of Inspector General (OIG), HHS. ACTION... statute (section 1128B(b) of the Social Security Act), as well as developing new OIG Special Fraud Alerts... revised safe harbors and Special Fraud Alerts. Please assist us by referencing the file code OIG-122-N...

  9. 77 FR 76434 - Solicitation of New Safe Harbors and Special Fraud Alerts

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-28

    ... of New Safe Harbors and Special Fraud Alerts AGENCY: Office of Inspector General (OIG), HHS. ACTION... statute (section 1128B(b) of the Social Security Act), as well as developing new OIG Special Fraud Alerts... revised safe harbors and Special Fraud Alerts. Please assist us by referencing the file code OIG-121-N...

  10. With Free Google Alert Services

    ERIC Educational Resources Information Center

    Gunn, Holly

    2005-01-01

    Alert services are a great way of keeping abreast of topics that interest you. Rather than searching the Web regularly to find new content about your areas of interest, an alert service keeps you informed by sending you notices when new material is added to the Web that matches your registered search criteria. Alert services are examples of push…

  11. Developing an Early-Alert System to Promote Student Visits to Tutor Center

    ERIC Educational Resources Information Center

    Cai, Qijie; Lewis, Carrie L.; Higdon, Jude

    2015-01-01

    An early-alert system (MavCLASS) was developed and piloted in a large gateway math class with 611 freshman students to identify academically at-risk students and provide alert messages. It was found that there was significant association between the alert messages students received and their visits to the university's tutor center. Further, the…

  12. 47 CFR 80.1117 - Procedure for receipt and acknowledgement of distress alerts.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... radiotelephony of receipt of a distress alert from a ship station or a ship earth station must be given in the... telegraphy of receipt of a distress alert from a ship earth station must be given by the coast earth station... distress alerts. 80.1117 Section 80.1117 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED...

  13. 47 CFR 80.1117 - Procedure for receipt and acknowledgement of distress alerts.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... radiotelephony of receipt of a distress alert from a ship station or a ship earth station must be given in the... telegraphy of receipt of a distress alert from a ship earth station must be given by the coast earth station... distress alerts. 80.1117 Section 80.1117 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED...

  14. 47 CFR 80.1117 - Procedure for receipt and acknowledgement of distress alerts.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... radiotelephony of receipt of a distress alert from a ship station or a ship earth station must be given in the... telegraphy of receipt of a distress alert from a ship earth station must be given by the coast earth station... distress alerts. 80.1117 Section 80.1117 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED...

  15. Method and apparatus for extraction of low-frequency artifacts from brain waves for alertness detection

    DOEpatents

    Clapp, Ned E.; Hively, Lee M.

    1997-01-01

    Methods and apparatus automatically detect alertness in humans by monitoring and analyzing brain wave signals. Steps include: acquiring the brain wave (EEG or MEG) data from the subject, digitizing the data, separating artifact data from raw data, and comparing trends in f-data to alertness indicators, providing notification of inadequate alertness.

  16. Predictive Information: Status or Alert Information?

    NASA Technical Reports Server (NTRS)

    Trujillo, Anna C.; Bruneau, Daniel; Press, Hayes N.

    2008-01-01

    Previous research investigating the efficacy of predictive information for detecting and diagnosing aircraft system failures found that subjects like to have predictive information concerning when a parameter would reach an alert range. This research focused on where the predictive information should be located, whether the information should be more closely associated with the parameter information or with the alert information. Each subject saw 3 forms of predictive information: (1) none, (2) a predictive alert message, and (3) predictive information on the status display. Generally, subjects performed better and preferred to have predictive information available although the difference between status and alert predictive information was minimal. Overall, for detection and recalling what happened, status predictive information is best; however for diagnosis, alert predictive information holds a slight edge.

  17. PubMedAlertMe - Standalone Windows-based PubMed SDI Software Application

    PubMed Central

    Ma’ayan, Avi

    2008-01-01

    PubMedAlertMe is a Windows-based software system for automatically receiving e-mail alert messages about recent publications listed on PubMed. The e-mail messages contain links to newly available abstracts listed on PubMed describing publications that were selectively returned from a specified list of queries. Links are also provided to directly export citations to EndNote, and links are provided to directly forward articles to colleagues. The program is standalone. Thus, it does not require a remote mail server or user registration. PubMedAlertMe is free software, and can be downloaded from: http://amp.pharm.mssm.edu/PubMedAlertMe/PubMedAlertMe_setup.zip PMID:18402930

  18. Static, Dynamic, and Fatigue Analysis of the Mechanical System of Ultrasonic Scanner for Inservice Inspection of Research Reactors

    NASA Astrophysics Data System (ADS)

    Awwaluddin, Muhammad; Kristedjo, K.; Handono, Khairul; Ahmad, H.

    2018-02-01

    This analysis is conducted to determine the effects of static and dynamic loads of the structure of mechanical system of Ultrasonic Scanner i.e., arm, column, and connection systems for inservice inspection of research reactors. The analysis is performed using the finite element method with 520 N static load. The correction factor of dynamic loads used is the Gerber mean stress correction (stress life). The results of the analysis show that the value of maximum equivalent von Mises stress is 1.3698E8 Pa for static loading and value of the maximum equivalent alternating stress is 1.4758E7 Pa for dynamic loading. These values are below the upper limit allowed according to ASTM A240 standards i.e. 2.05E8 Pa. The result analysis of fatigue life cycle are at least 1E6 cycle, so it can be concluded that the structure is in the high life cycle category.

  19. Design of decision support interventions for medication prescribing.

    PubMed

    Horsky, Jan; Phansalkar, Shobha; Desai, Amrita; Bell, Douglas; Middleton, Blackford

    2013-06-01

    Describe optimal design attributes of clinical decision support (CDS) interventions for medication prescribing, emphasizing perceptual, cognitive and functional characteristics that improve human-computer interaction (HCI) and patient safety. Findings from published reports on success, failures and lessons learned during implementation of CDS systems were reviewed and interpreted with regard to HCI and software usability principles. We then formulated design recommendations for CDS alerts that would reduce unnecessary workflow interruptions and allow clinicians to make informed decisions quickly, accurately and without extraneous cognitive and interactive effort. Excessive alerting that tends to distract clinicians rather than provide effective CDS can be reduced by designing only high severity alerts as interruptive dialog boxes and less severe warnings without explicit response requirement, by curating system knowledge bases to suppress warnings with low clinical utility and by integrating contextual patient data into the decision logic. Recommended design principles include parsimonious and consistent use of color and language, minimalist approach to the layout of information and controls, the use of font attributes to convey hierarchy and visual prominence of important data over supporting information, the inclusion of relevant patient data in the context of the alert and allowing clinicians to respond with one or two clicks. Although HCI and usability principles are well established and robust, CDS and EHR system interfaces rarely conform to the best known design conventions and are seldom conceived and designed well enough to be truly versatile and dependable tools. These relatively novel interventions still require careful monitoring, research and analysis of its track record to mature. Clarity and specificity of alert content and optimal perceptual and cognitive attributes, for example, are essential for providing effective decision support to clinicians. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  20. Analysis and critical comparison of food allergen recalls from the European Union, USA, Canada, Hong Kong, Australia and New Zealand.

    PubMed

    Bucchini, Luca; Guzzon, Antonella; Poms, Roland; Senyuva, Hamide

    2016-05-01

    As part of a European Union-funded project (FP7) developing 'Integrated approaches to food allergen and allergy management', a database was constructed based on publicly available information on food allergen recalls in Europe, North America, Hong Kong, Australia and New Zealand. Over 2000 entries were made into the database. The database covers a 4-year period from 2011 to 2014 and each entry is categorised into food type (two different classifications), identified allergen and cause where indicated by the authorities. Across different authorities, by far the biggest incidence of undeclared allergens occurred in the food categories of prepared dishes and snacks (range = 12-53%), and cereals and bakery products (range = 14-25% of all recalls and/or alerts). The biggest incidence of undeclared allergens, according to the information from most authorities, occurred for milk and milk products (16-31% of all products with recall or alert), followed by cereals containing gluten (9-19%), soy (5-45%), and egg and egg products (5-17%). Although 42-90% of the products with recalls/alerts were explained as being 'Not indicated on the label', this is a generic explanation of cause and does not provide much insight into the causes of the recall/alerts. However, 0-17% of products with recalls/alerts could be coded as caused by the unintended presence of an allergen as the probable result of cross-contact in production. Construction of the database of allergen recalls has provided some important lessons and recommendations to the authorities are made in this paper in terms of the harmonisation of the reporting of allergen recalls into a more standardised format.

  1. Analysis of clinical decision support system malfunctions: a case series and survey.

    PubMed

    Wright, Adam; Hickman, Thu-Trang T; McEvoy, Dustin; Aaron, Skye; Ai, Angela; Andersen, Jan Marie; Hussain, Salman; Ramoni, Rachel; Fiskio, Julie; Sittig, Dean F; Bates, David W

    2016-11-01

    To illustrate ways in which clinical decision support systems (CDSSs) malfunction and identify patterns of such malfunctions. We identified and investigated several CDSS malfunctions at Brigham and Women's Hospital and present them as a case series. We also conducted a preliminary survey of Chief Medical Information Officers to assess the frequency of such malfunctions. We identified four CDSS malfunctions at Brigham and Women's Hospital: (1) an alert for monitoring thyroid function in patients receiving amiodarone stopped working when an internal identifier for amiodarone was changed in another system; (2) an alert for lead screening for children stopped working when the rule was inadvertently edited; (3) a software upgrade of the electronic health record software caused numerous spurious alerts to fire; and (4) a malfunction in an external drug classification system caused an alert to inappropriately suggest antiplatelet drugs, such as aspirin, for patients already taking one. We found that 93% of the Chief Medical Information Officers who responded to our survey had experienced at least one CDSS malfunction, and two-thirds experienced malfunctions at least annually. CDSS malfunctions are widespread and often persist for long periods. The failure of alerts to fire is particularly difficult to detect. A range of causes, including changes in codes and fields, software upgrades, inadvertent disabling or editing of rules, and malfunctions of external systems commonly contribute to CDSS malfunctions, and current approaches for preventing and detecting such malfunctions are inadequate. CDSS malfunctions occur commonly and often go undetected. Better methods are needed to prevent and detect these malfunctions. © The Author 2016. Published by Oxford University Press on behalf of the American Medical Informatics Association.

  2. Intuitive Analysis of Variance-- A Formative Assessment Approach

    ERIC Educational Resources Information Center

    Trumpower, David

    2013-01-01

    This article describes an assessment activity that can show students how much they intuitively understand about statistics, but also alert them to common misunderstandings. How the activity can be used formatively to help improve students' conceptual understanding of analysis of variance is discussed. (Contains 1 figure and 1 table.)

  3. Comparative analytics of infusion pump data across multiple hospital systems.

    PubMed

    Catlin, Ann Christine; Malloy, William X; Arthur, Karen J; Gaston, Cindy; Young, James; Fernando, Sudheera; Fernando, Ruchith

    2015-02-15

    A Web-based analytics system for conducting inhouse evaluations and cross-facility comparisons of alert data generated by smart infusion pumps is described. The Infusion Pump Informatics (IPI) project, a collaborative effort led by research scientists at Purdue University, was launched in 2009 to provide advanced analytics and tools for workflow analyses to assist hospitals in determining the significance of smart-pump alerts and reducing nuisance alerts. The IPI system allows facility-specific analyses of alert patterns and trends, as well as cross-facility comparisons of alert data uploaded by more than 55 participating institutions using different types of smart pumps. Tools accessible through the IPI portal include (1) charts displaying aggregated or breakout data on the top drugs associated with alerts, numbers of alerts per device or care area, and override-to-alert ratios, (2) investigative reports that can be used to characterize and analyze pump-programming errors in a variety of ways (e.g., by drug, by infusion type, by time of day), and (3) "drill-down" workflow analytics enabling users to evaluate alert patterns—both internally and in relation to patterns at other hospitals—in a quick and efficient stepwise fashion. The formation of the IPI analytics system to support a community of hospitals has been successful in providing sophisticated tools for member facilities to review, investigate, and efficiently analyze smart-pump alert data, not only within a member facility but also across other member facilities, to further enhance smart pump drug library design. Copyright © 2015 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  4. Impact of faxed health alerts on the preparedness of general practitioners during communicable disease outbreaks.

    PubMed

    Rosewell, Alexander; Patel, Mahomed; Viney, Kerri; Marich, Andrew; Lawrence, Glenda L

    2010-03-01

    The NSW Department of Health (NSW Health) faxed health alerts to general medical practitioners during measles outbreaks in March and May 2006. We conducted a retrospective cohort study of randomly selected general practitioners (GPs) (1 per medical practice) in New South Wales to investigate the effectiveness of faxing health alerts to GPs during a communicable disease outbreak. Fax transmission data allowed comparison of GPs sent and not sent the measles alert for self-reported awareness and practice actions aimed at the prevention and control of measles. A total of 328 GPs participated in the study. GPs who were sent the alert were more likely to be aware of the measles outbreak (RR 1.18, 95% CI 1.02, 1.38). When analysed by whether a fax had been received from either NSW Health or the Australian General Practice Network, GPs who reported receiving a faxed measles alert were more likely to be aware of the outbreak (RR 2.56, 95% CI 1.84, 3.56), to offer vaccination to susceptible staff (RR 6.46, 95% CI 2.49, 16.78), and be aware of other infection control recommendations. Respondents reported that the faxed alerts were useful with 65% reporting that the alerts had reminded them to consider measles in the differential diagnosis. This study shows that faxed health alerts were useful for preparing GPs to respond effectively to a communicable disease outbreak. The fax alert system could be improved by ensuring that all general practices in New South Wales are included in the faxstream database and that their contact details are updated regularly.

  5. Collaborative knowledge acquisition for the design of context-aware alert systems.

    PubMed

    Joffe, Erel; Havakuk, Ofer; Herskovic, Jorge R; Patel, Vimla L; Bernstam, Elmer Victor

    2012-01-01

    To present a framework for combining implicit knowledge acquisition from multiple experts with machine learning and to evaluate this framework in the context of anemia alerts. Five internal medicine residents reviewed 18 anemia alerts, while 'talking aloud'. They identified features that were reviewed by two or more physicians to determine appropriate alert level, etiology and treatment recommendation. Based on these features, data were extracted from 100 randomly-selected anemia cases for a training set and an additional 82 cases for a test set. Two staff internists assigned an alert level, etiology and treatment recommendation before and after reviewing the entire electronic medical record. The training set of 118 cases (100 plus 18) and the test set of 82 cases were explored using RIDOR and JRip algorithms. The feature set was sufficient to assess 93% of anemia cases (intraclass correlation for alert level before and after review of the records by internists 1 and 2 were 0.92 and 0.95, respectively). High-precision classifiers were constructed to identify low-level alerts (precision p=0.87, recall R=0.4), iron deficiency (p=1.0, R=0.73), and anemia associated with kidney disease (p=0.87, R=0.77). It was possible to identify low-level alerts and several conditions commonly associated with chronic anemia. This approach may reduce the number of clinically unimportant alerts. The study was limited to anemia alerts. Furthermore, clinicians were aware of the study hypotheses potentially biasing their evaluation. Implicit knowledge acquisition, collaborative filtering and machine learning were combined automatically to induce clinically meaningful and precise decision rules.

  6. Perceptual evaluation of visual alerts in surveillance videos

    NASA Astrophysics Data System (ADS)

    Rogowitz, Bernice E.; Topkara, Mercan; Pfeiffer, William; Hampapur, Arun

    2015-03-01

    Visual alerts are commonly used in video monitoring and surveillance systems to mark events, presumably making them more salient to human observers. Surprisingly, the effectiveness of computer-generated alerts in improving human performance has not been widely studied. To address this gap, we have developed a tool for simulating different alert parameters in a realistic visual monitoring situation, and have measured human detection performance under conditions that emulated different set-points in a surveillance algorithm. In the High-Sensitivity condition, the simulated alerts identified 100% of the events with many false alarms. In the Lower-Sensitivity condition, the simulated alerts correctly identified 70% of the targets, with fewer false alarms. In the control condition, no simulated alerts were provided. To explore the effects of learning, subjects performed these tasks in three sessions, on separate days, in a counterbalanced, within subject design. We explore these results within the context of cognitive models of human attention and learning. We found that human observers were more likely to respond to events when marked by a visual alert. Learning played a major role in the two alert conditions. In the first session, observers generated almost twice as many False Alarms as in the No-Alert condition, as the observers responded pre-attentively to the computer-generated false alarms. However, this rate dropped equally dramatically in later sessions, as observers learned to discount the false cues. Highest observer Precision, Hits/(Hits + False Alarms), was achieved in the High Sensitivity condition, but only after training. The successful evaluation of surveillance systems depends on understanding human attention and performance.

  7. Human Factors Evaluation of Conflict Detection Tool for Terminal Area

    NASA Technical Reports Server (NTRS)

    Verma, Savita Arora; Tang, Huabin; Ballinger, Deborah; Chinn, Fay Cherie; Kozon, Thomas E.

    2013-01-01

    A conflict detection and resolution tool, Terminal-area Tactical Separation-Assured Flight Environment (T-TSAFE), is being developed to improve the timeliness and accuracy of alerts and reduce the false alert rate observed with the currently deployed technology. The legacy system in use today, Conflict Alert, relies primarily on a dead reckoning algorithm, whereas T-TSAFE uses intent information to augment dead reckoning. In previous experiments, T-TSAFE was found to reduce the rate of false alerts and increase time between the alert to the controller and a loss of separation over the legacy system. In the present study, T-TSAFE was tested under two meteorological conditions, 1) all aircraft operated under instrument flight regimen, and 2) some aircraft operated under mixed operating conditions. The tool was used to visually alert controllers to predicted Losses of separation throughout the terminal airspace, and show compression errors, on final approach. The performance of T-TSAFE on final approach was compared with Automated Terminal Proximity Alert (ATPA), a tool recently deployed by the FAA. Results show that controllers did not report differences in workload or situational awareness between the T-TSAFE and ATPA cones but did prefer T-TSAFE features over ATPA functionality. T-TSAFE will provide one tool that shows alerts in the data blocks and compression errors via cones on the final approach, implementing all tactical conflict detection and alerting via one tool in TRACON airspace.

  8. 78 FR 53774 - Guide for the Evaluation of Alert and Notification Systems for Nuclear Power Plants, FEMA-REP-10...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-30

    ...] Guide for the Evaluation of Alert and Notification Systems for Nuclear Power Plants, FEMA-REP-10, Rev. 1... the Guide for the Evaluation of Alert and Notification Systems for Nuclear Power Plants, FEMA-REP-10... Agency (FEMA) issued FEMA-REP-10, Guide for the Evaluation of Alert and Notification Systems for Nuclear...

  9. Method and apparatus for extraction of low-frequency artifacts from brain waves for alertness detection

    DOEpatents

    Clapp, N.E.; Hively, L.M.

    1997-05-06

    Methods and apparatus automatically detect alertness in humans by monitoring and analyzing brain wave signals. Steps include: acquiring the brain wave (EEG or MEG) data from the subject, digitizing the data, separating artifact data from raw data, and comparing trends in f-data to alertness indicators, providing notification of inadequate alertness. 4 figs.

  10. A CCTV system with SMS alert (CMDSA): An implementation of pixel processing algorithm for motion detection

    NASA Astrophysics Data System (ADS)

    Rahman, Nurul Hidayah Ab; Abdullah, Nurul Azma; Hamid, Isredza Rahmi A.; Wen, Chuah Chai; Jelani, Mohamad Shafiqur Rahman Mohd

    2017-10-01

    Closed-Circuit TV (CCTV) system is one of the technologies in surveillance field to solve the problem of detection and monitoring by providing extra features such as email alert or motion detection. However, detecting and alerting the admin on CCTV system may complicate due to the complexity to integrate the main program with an external Application Programming Interface (API). In this study, pixel processing algorithm is applied due to its efficiency and SMS alert is added as an alternative solution for users who opted out email alert system or have no Internet connection. A CCTV system with SMS alert (CMDSA) was developed using evolutionary prototyping methodology. The system interface was implemented using Microsoft Visual Studio while the backend components, which are database and coding, were implemented on SQLite database and C# programming language, respectively. The main modules of CMDSA are motion detection, capturing and saving video, image processing and Short Message Service (SMS) alert functions. Subsequently, the system is able to reduce the processing time making the detection process become faster, reduce the space and memory used to run the program and alerting the system admin instantly.

  11. A COMPARATIVE STUDY OF REAL-TIME AND STATIC ULTRASONOGRAPHY DIAGNOSES FOR THE INCIDENTAL DETECTION OF DIFFUSE THYROID DISEASE.

    PubMed

    Kim, Dong Wook

    2015-08-01

    The aim of this study was to compare the diagnostic accuracy of real-time and static ultrasonography (US) for the incidental detection of diffuse thyroid disease (DTD). In 118 consecutive patients, a single radiologist performed real-time US before thyroidectomy. For static US, the same radiologist retrospectively investigated the sonographic findings on a picture-archiving and communication system after 3 months. The diagnostic categories of both real-time and static US diagnoses were determined based on the number of abnormal findings, and the diagnostic indices were calculated by a receiver operating characteristic (ROC) curve analysis using the histopathologic results as the reference standard. Histopathologic results included normal thyroid (n = 77), Hashimoto thyroiditis (n = 11), non-Hashimoto lymphocytic thyroiditis (n = 29), and diffuse hyperplasia (n = 1). Normal thyroid and DTD showed significant differences in echogenicity, echotexture, glandular margin, and vascularity on both real-time and static US. There was a positive correlation between US categories and histopathologic results in both real-time and static US. The highest diagnostic indices were obtained when the cutoff criteria of real-time and static US diagnoses were chosen as indeterminate and suspicious for DTD, respectively. The ROC curve analysis showed that real-time US was superior to static US in diagnostic accuracy. Both real-time and static US may be helpful for the detection of incidental DTD, but real-time US is superior to static US for detecting incidental DTD.

  12. Development of an Alert System to Detect Drug Interactions with Herbal Supplements using Medical Record Data.

    PubMed

    Archer, Melissa; Proulx, Joshua; Shane-McWhorter, Laura; Bray, Bruce E; Zeng-Treitler, Qing

    2014-01-01

    While potential medication-to-medication interaction alerting engines exist in many clinical applications, few systems exist to automatically alert on potential medication to herbal supplement interactions. We have developed a preliminary knowledge base and rules alerting engine that detects 259 potential interactions between 9 supplements, 62 cardiac medications, and 19 drug classes. The rules engine takes into consideration 12 patient risk factors and 30 interaction warning signs to help determine which of three different alert levels to categorize each potential interaction. A formative evaluation was conducted with two clinicians to set initial thresholds for each alert level. Additional work is planned add more supplement interactions, risk factors, and warning signs as well as to continue to set and adjust the inputs and thresholds for each potential interaction.

  13. Stability of the Einstein static universe in open cosmological models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Canonico, Rosangela; Parisi, Luca; INFN, Sezione di Napoli, GC di Salerno, Via Ponte Don Melillo, I-84081 Baronissi

    2010-09-15

    The stability properties of the Einstein static solution of general relativity are altered when corrective terms arising from modification of the underlying gravitational theory appear in the cosmological equations. In this paper the existence and stability of static solutions are considered in the framework of two recently proposed quantum gravity models. The previously known analysis of the Einstein static solutions in the semiclassical regime of loop quantum cosmology with modifications to the gravitational sector is extended to open cosmological models where a static neutrally stable solution is found. A similar analysis is also performed in the framework of Horava-Lifshitz gravitymore » under detailed balance and projectability conditions. In the case of open cosmological models the two solutions found can be either unstable or neutrally stable according to the admitted values of the parameters.« less

  14. JPL's GNSS Real-Time Earthquake and Tsunami (GREAT) Alert System

    NASA Astrophysics Data System (ADS)

    Bar-Sever, Yoaz; Miller, Mark; Vallisneri, Michele; Khachikyan, Robert; Meyer, Robert

    2017-04-01

    We describe recent developments to the GREAT Alert natural hazard monitoring service from JPL's Global Differential GPS (GDGPS) System. GREAT Alert provides real-time, 1 Hz positioning solutions for hundreds of GNSS tracking sites, from both global and regional networks, aiming to monitor ground motion in the immediate aftermath of earthquakes. We take advantage of the centralized data processing, which is collocated with the GNSS orbit determination operations of the GDGPS System, to combine orbit determination with large-scale point-positioning in a grand estimation scheme, and as a result realize significant improvement to the positioning accuracy compared to conventional stand-alone point positioning techniques. For example, the measured median site (over all sites) real-time horizontal positioning accuracy is 2 cm 1DRMS, and the median real-time vertical accuracy is 4 cm RMS. The GREAT Alert positioning service is integrated with automated global earthquake notices from the United States Geodetic Survey (USGS) to support near-real-time calculations of co-seismic displacements with attendant formal errors based both short-term and long-term error analysis for each individual site. We will show the millimeter-level resolution of co-seismic displacement can be achieved by this system. The co-seismic displacements, in turn, are fed into a JPL geodynamics and ocean models, that estimate the Earthquake magnitude and predict the potential tsunami scale.

  15. Pilot Non-Conformance to Alerting System Commands

    NASA Technical Reports Server (NTRS)

    Pritchett, Amy R.; Hansman, R. John

    1997-01-01

    Instances of pilot non-conformance to alerting system commands have been identified in previous studies. Pilot non-conformance changes the final behavior of the system, and therefore may reduce actual performance from that anticipated. A simulator study has examined pilot non-conformance, using the task of collision avoidance during closely spaced parallel approaches as a case study. Consonance between the display and the alerting system was found to significantly improve subject agreement with automatic alerts. Based on these results, a more general discussion of the factors involved in pilot conformance is given, and design guidelines for alerting systems are given.

  16. Impact of real-time electronic alerting of acute kidney injury on therapeutic intervention and progression of RIFLE class.

    PubMed

    Colpaert, Kirsten; Hoste, Eric A; Steurbaut, Kristof; Benoit, Dominique; Van Hoecke, Sofie; De Turck, Filip; Decruyenaere, Johan

    2012-04-01

    To evaluate whether a real-time electronic alert system or "AKI sniffer," which is based on the RIFLE classification criteria (Risk, Injury and Failure), would have an impact on therapeutic interventions and acute kidney injury progression. Prospective intervention study. Surgical and medical intensive care unit in a tertiary care hospital. A total of 951 patients having in total 1,079 admission episodes were admitted during the study period (prealert control group: 227, alert group: 616, and postalert control group: 236). Three study phases were compared: A 1.5-month prealert control phase in which physicians were blinded for the acute kidney injury sniffer and a 3-month intervention phase with real-time alerting of worsening RIFLE class through the Digital Enhanced Cordless Technology telephone system followed by a second 1.5-month postalert control phase. A total of 2593 acute kidney injury alerts were recorded with a balanced distribution over all study phases. Most acute kidney injury alerts were RIFLE class risk (59.8%) followed by RIFLE class injury (34.1%) and failure (6.1%). A higher percentage of patients in the alert group received therapeutic intervention within 60 mins after the acute kidney injury alert (28.7% in alert group vs. 7.9% and 10.4% in the pre- and postalert control groups, respectively, p μ .001). In the alert group, more patients received fluid therapy (23.0% vs. 4.9% and 9.2%, p μ .01), diuretics (4.2% vs. 2.6% and 0.8%, p μ .001), or vasopressors (3.9% vs. 1.1% and 0.8%, p μ .001). Furthermore, these patients had a shorter time to intervention (p μ .001). A higher proportion of patients in the alert group showed return to a baseline kidney function within 8 hrs after an acute kidney injury alert "from normal to risk" compared with patients in the control group (p = .048). The real-time alerting of every worsening RIFLE class by the acute kidney injury sniffer increased the number and timeliness of early therapeutic interventions. The borderline significant improvement of short-term renal outcome in the RIFLE class risk patients needs to be confirmed in a large multicenter trial.

  17. 77 FR 6000 - Airworthiness Directives; Aviation Communication & Surveillance Systems (ACSS) Traffic Alert and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-07

    ... Airworthiness Directives; Aviation Communication & Surveillance Systems (ACSS) Traffic Alert and Collision... Communication & Surveillance Systems (ACSS) traffic alert and collision avoidance system (TCAS) units with part...

  18. Medical alert bracelet (image)

    MedlinePlus

    People with diabetes should always wear a medical alert bracelet or necklace that emergency medical workers will ... People with diabetes should always wear a medical alert bracelet or necklace that emergency medical workers will ...

  19. Divers Alert Network

    MedlinePlus

    ... is Your Dive Safety Association Divers Alert Network DAN is Divers Alert Network, the diving industry’s largest ... Serving scuba divers for more than 30 years, DAN provides emergency assistance, medical information resources, educational opportunities ...

  20. Terminal Area Conflict Detection and Resolution Tool

    NASA Technical Reports Server (NTRS)

    Verma, Savita Arora

    2011-01-01

    This poster will describe analysis of a conflict detection and resolution tool for the terminal area called T-TSAFE. With altitude clearance information, the tool can reduce false alerts to as low as 2 per hour.

  1. The Neglect of Monotone Comparative Statics Methods

    ERIC Educational Resources Information Center

    Tremblay, Carol Horton; Tremblay, Victor J.

    2010-01-01

    Monotone methods enable comparative static analysis without the restrictive assumptions of the implicit-function theorem. Ease of use and flexibility in solving comparative static and game-theory problems have made monotone methods popular in the economics literature and in graduate courses, but they are still absent from undergraduate…

  2. Successful ShakeAlert Performance for the Napa Quake

    NASA Astrophysics Data System (ADS)

    Allen, R. M.; Given, D. D.; Heaton, T. H.; Vidale, J. E.

    2014-12-01

    ShakeAlert, the demonstration earthquake early warning system, developed by the USGS, UC Berkeley, Caltech, ETH, and the University of Washington, functioned as expected for the August 24, 2014, M6.0 Napa earthquake. The first ShakeAlert was generated by the ElarmS algorithm 5.1 sec after the origin time of the earthquake, and 3.3 sec after the P-wave arrived at the closest station 6.5 km from the epicenter. This initial alert, based on P-wave triggers from four stations, estimated the magnitude to be 5.7. The warning was received at the UC Berkeley Seismological Laboratory 5 seconds before the S-wave and about 10 sec prior to the onset of the strongest shaking. ShakeAlert beta-testers across the San Francisco Bay Area simultaneously received the alert, including the San Francisco 911 center with 8 sec warning, and the BART train system. BART has implemented an automated train-stopping system that was activated (although no trains were running at 3:20 am). With the available network geometry and communications, the blind zone of the first alert had a radius of 16 km. The four stations that contributed to the first alert all encapsulate data into 1-second packets, but the latency in transmitting data to the processing center ranged from 0.27 to 2.62 seconds. If all the stations were to deliver data in 0.27 seconds, then the alert would have been available 2.3 sec sooner and the blind zone would be reduced to about 8 km. This would also mean that the city of Napa would have received about 1 second of warning. The magnitude estimate and event location were accurate from the initial alert onwards. The magnitude estimate did first increase to 5.8 and then dip to 5.4 2.6 sec after the initial alert, stayed at that level for 2 sec, and then returned to 5.7. The final magnitude estimate was 6.0, consistent with the ANSS catalog.

  3. Automated inhaled nitric oxide alerts for adult extracorporeal membrane oxygenation patient identification.

    PubMed

    Belenkiy, Slava M; Batchinsky, Andriy I; Park, Timothy S; Luellen, David E; Serio-Melvin, Maria L; Cancio, Leopoldo C; Pamplin, Jeremy C; Chung, Kevin K; Salinas, Josè; Cannon, Jeremy W

    2014-09-01

    Recently, automated alerts have been used to identify patients with respiratory failure based on set criteria, which can be gleaned from the electronic medical record (EMR). Such an approach may also be useful for identifying patients with severe adult respiratory distress syndrome (ARDS) who may benefit from extracorporeal membrane oxygenation (ECMO). Inhaled nitric oxide (iNO) is a common rescue therapy for severe ARDS which can be easily tracked in the EMR, and some patients started on iNO may have indications for initiating ECMO. This case series summarizes our experience with using automated electronic alerts for ECMO team activation focused particularly on an alert triggered by the initiation of iNO. After a brief trial evaluation, our Smart Alert system generated an automated page and e-mail alert to ECMO team members whenever a nonzero value for iNO appeared in the respiratory care section of our EMR. If iNO was initiated for severe respiratory failure, a detailed evaluation by the ECMO team determined if ECMO was indicated. For those patients managed with ECMO, we tabulated baseline characteristics, indication for ECMO, and outcomes. From September 2012 to July 2013, 45 iNO alerts were generated on 42 unique patients. Six patients (14%) met criteria for ECMO. Of these, four were identified exclusively by the iNO alert. At the time of the alert, the median PaO₂-to-FIO₂ ratio was 64 mm Hg (range, 55-107 mm Hg), the median age-adjusted oxygenation index was 73 (range, 51-96), and the median Murray score was 3.4 (range, 3-3.75), indicating severe respiratory failure. Median time from iNO alert to ECMO initiation was 81 hours (range, -2-292 hours). Survival to hospital discharge was 83% in those managed with ECMO. Automated alerts may be useful for identifying patients with severe ARDS who may be ECMO candidates. Diagnostic test, level V.

  4. Experimental Study of Collision Detection Schema Used by Pilots During Closely Spaced Parallel Approaches

    NASA Technical Reports Server (NTRS)

    Pritchett, Amy R.; Hansman, R. John

    1996-01-01

    An experimental flight simulator study was conducted to examine the mental alerting logic and thresholds used by subjects to issue an alert and execute an avoidance maneuver. Subjects flew a series of autopilot landing approaches with traffic on a closely-spaced parallel approach; during some runs, the traffic would deviate towards the subject and the subject was to indicate the point when they recognized the potential traffic conflict, and then indicate a direction of flight for an avoidance maneuver. A variety of subjects, including graduate students, general aviation pilots and airline pilots, were tested. Five traffic displays were evaluated, with a moving map TCAS-type traffic display as a baseline. A side-task created both high and low workload situations. Subjects appeared to use the lateral deviation of the intruder aircraft from its approach path as the criteria for an alert regardless of the display available. However, with displays showing heading and/or trend information, their alerting thresholds were significantly lowered. This type of range-only schema still resulted in many near misses, as a high convergence rate was often established by the time of the subject's alert. Therefore, the properties of the intruder's trajectory had the greatest effect on the resultant near miss rate; no display system reliably caused alerts timely enough for certain collision avoidance. Subjects' performance dropped significantly on a side-task while they analyzed the need for an alert, showing alert generation can be a high workload situation at critical times. No variation was found between subjects with and with out piloting experience. These results suggest the design of automatic alerting systems should take into account the range-type alerting schema used by the human, such that the rationale for the automatic alert should be obvious to, and trusted by, the operator. Although careful display design may help generate pilot/automation trust, issues such as user non-conformance to automatically generated commands can remain a possibility.

  5. The Tölz Temporal Topography Study: mapping the visual field across the life span. Part II: cognitive factors shaping visual field maps.

    PubMed

    Poggel, Dorothe A; Treutwein, Bernhard; Calmanti, Claudia; Strasburger, Hans

    2012-08-01

    Part I described the topography of visual performance over the life span. Performance decline was explained only partly by deterioration of the optical apparatus. Part II therefore examines the influence of higher visual and cognitive functions. Visual field maps for 95 healthy observers of static perimetry, double-pulse resolution (DPR), reaction times, and contrast thresholds, were correlated with measures of visual attention (alertness, divided attention, spatial cueing), visual search, and the size of the attention focus. Correlations with the attentional variables were substantial, particularly for variables of temporal processing. DPR thresholds depended on the size of the attention focus. The extraction of cognitive variables from the correlations between topographical variables and participant age substantially reduced those correlations. There is a systematic top-down influence on the aging of visual functions, particularly of temporal variables, that largely explains performance decline and the change of the topography over the life span.

  6. Airport Traffic Conflict Detection and Resolution Algorithm Evaluation

    NASA Technical Reports Server (NTRS)

    Jones, Denise R.; Chartrand, Ryan C.; Wilson, Sara R.; Commo, Sean A.; Ballard, Kathryn M.; Otero, Sharon D.; Barker, Glover D.

    2016-01-01

    Two conflict detection and resolution (CD&R) algorithms for the terminal maneuvering area (TMA) were evaluated in a fast-time batch simulation study at the National Aeronautics and Space Administration (NASA) Langley Research Center. One CD&R algorithm, developed at NASA, was designed to enhance surface situation awareness and provide cockpit alerts of potential conflicts during runway, taxi, and low altitude air-to-air operations. The second algorithm, Enhanced Traffic Situation Awareness on the Airport Surface with Indications and Alerts (SURF IA), was designed to increase flight crew awareness of the runway environment and facilitate an appropriate and timely response to potential conflict situations. The purpose of the study was to evaluate the performance of the aircraft-based CD&R algorithms during various runway, taxiway, and low altitude scenarios, multiple levels of CD&R system equipage, and various levels of horizontal position accuracy. Algorithm performance was assessed through various metrics including the collision rate, nuisance and missed alert rate, and alert toggling rate. The data suggests that, in general, alert toggling, nuisance and missed alerts, and unnecessary maneuvering occurred more frequently as the position accuracy was reduced. Collision avoidance was more effective when all of the aircraft were equipped with CD&R and maneuvered to avoid a collision after an alert was issued. In order to reduce the number of unwanted (nuisance) alerts when taxiing across a runway, a buffer is needed between the hold line and the alerting zone so alerts are not generated when an aircraft is behind the hold line. All of the results support RTCA horizontal position accuracy requirements for performing a CD&R function to reduce the likelihood and severity of runway incursions and collisions.

  7. Collaborative knowledge acquisition for the design of context-aware alert systems

    PubMed Central

    Joffe, Erel; Havakuk, Ofer; Herskovic, Jorge R; Patel, Vimla L

    2012-01-01

    Objective To present a framework for combining implicit knowledge acquisition from multiple experts with machine learning and to evaluate this framework in the context of anemia alerts. Materials and Methods Five internal medicine residents reviewed 18 anemia alerts, while ‘talking aloud’. They identified features that were reviewed by two or more physicians to determine appropriate alert level, etiology and treatment recommendation. Based on these features, data were extracted from 100 randomly-selected anemia cases for a training set and an additional 82 cases for a test set. Two staff internists assigned an alert level, etiology and treatment recommendation before and after reviewing the entire electronic medical record. The training set of 118 cases (100 plus 18) and the test set of 82 cases were explored using RIDOR and JRip algorithms. Results The feature set was sufficient to assess 93% of anemia cases (intraclass correlation for alert level before and after review of the records by internists 1 and 2 were 0.92 and 0.95, respectively). High-precision classifiers were constructed to identify low-level alerts (precision p=0.87, recall R=0.4), iron deficiency (p=1.0, R=0.73), and anemia associated with kidney disease (p=0.87, R=0.77). Discussion It was possible to identify low-level alerts and several conditions commonly associated with chronic anemia. This approach may reduce the number of clinically unimportant alerts. The study was limited to anemia alerts. Furthermore, clinicians were aware of the study hypotheses potentially biasing their evaluation. Conclusion Implicit knowledge acquisition, collaborative filtering and machine learning were combined automatically to induce clinically meaningful and precise decision rules. PMID:22744961

  8. Behavioral Modification of Intraoperative Hyperglycemia Management with a Novel Real-time Audiovisual Monitor.

    PubMed

    Sathishkumar, Subramanian; Lai, Manda; Picton, Paul; Kheterpal, Sachin; Morris, Michelle; Shanks, Amy; Ramachandran, Satya Krishna

    2015-07-01

    Hyperglycemia, defined as blood glucose (BG) levels above 200 mg/dl (11.1 mM), is associated with increased postoperative morbidity. Yet, the treatment standard for intraoperative glycemic control is poorly defined for noncardiac surgery. Little is known of the interindividual treatment variability or methods to modify intraoperative glycemic management behaviors. AlertWatch (AlertWatch, USA) is a novel audiovisual alert system that serves as a secondary patient monitor for use in operating rooms. The authors evaluated the influence of use of AlertWatch on intraoperative glycemic management behavior. AlertWatch displays historical patient data (risk factors and laboratory results) from multiple networked information systems, combined with the patient's live physiologic data. The authors extracted intraoperative data for 19 months to evaluate the relationship between AlertWatch usage and initiation of insulin treatment for hyperglycemia. Outcome associations were adjusted for physical status, case duration, procedural complexity, emergent procedure, fasting BG value, home insulin therapy, patient age, and primary anesthetist. Overall, 2,341 patients had documented intraoperative hyperglycemia. Use of AlertWatch (791 of 2,341; 33.5%) was associated with 55% increase in insulin treatment (496 of 791 [62.7%] with and 817 of 1,550 [52.7%] without AlertWatch; adjusted odds ratio [95% CI], 1.55 [1.23 to 1.95]; P < 0.001) and 44% increase in BG recheck after insulin administration (407 of 791 [51.5%] with AlertWatch and 655 of 1,550 [42.3%] in controls; adjusted odds ratio [95% CI], 1.44 [1.14 to 1.81]; P = 0.002). AlertWatch is associated with a significant increase in desirable intraoperative glycemic management behavior and may help achieve tighter intraoperative glycemic control.

  9. Strategies for Managing Smart Pump Alarm and Alert Fatigue: A Narrative Review.

    PubMed

    Shah, Parth K; Irizarry, Jamie; O'Neill, Sean

    2018-06-08

    Although smart infusion pumps are intended to prevent medication errors by alerting users about doses that exceed set thresholds, a large number of clinically insignificant alarms and alerts create the potential for alert and alarm fatigue. We searched the PubMed, Scopus, and Cumulative Index to Nursing and Allied Health Literature (CINAHL) databases for peer-reviewed literature (January 1, 2004-August 31, 2017) on managing smart pump alerts, alarms, and related fatigue. Twenty-nine articles that met the inclusion criteria were reviewed and organized into themes. Smart pumps give users two types of signals: alarms that indicate mechanical issues such as occlusion, air in the line, or low battery; and clinical alerts that indicate that a programmed dose exceeds a predefined safety limit. Mechanical alarms occur with greater frequency than clinical alerts, but alarms and alerts vary widely by pump model, patient population, time of day, month, and type of drug. Several causes of clinically insignificant alerts and alarms may be actionable, and strategies proposed in the literature include development of a multidisciplinary team to oversee the quality improvement effort with involvement of end users, standardization of medication administration practices, widening of drug limit library thresholds when clinically appropriate, maintaining up-to-date drug limit libraries, and interoperability. Whereas many strategies have been proposed, and case studies have been reported, none have been rigorously evaluated. In addition, more research is needed related to managing occlusion and air-in-line alarms, especially for complicated infusions. Future work should focus on the evaluation of specific and replicable alert and alarm reduction strategies with a greater emphasis on quantitative metrics. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  10. Impact of electronic-alerting of acute kidney injury: workgroup statements from the 15(th) ADQI Consensus Conference.

    PubMed

    Hoste, Eric A J; Kashani, Kianoush; Gibney, Noel; Wilson, F Perry; Ronco, Claudio; Goldstein, Stuart L; Kellum, John A; Bagshaw, Sean M

    2016-01-01

    Among hospitalized patients, acute kidney injury is common and associated with significant morbidity and risk for mortality. The use of electronic health records (EHR) for prediction and detection of this important clinical syndrome has grown in the past decade. The steering committee of the 15(th) Acute Dialysis Quality Initiative (ADQI) conference dedicated a workgroup with the task of identifying elements that may impact the course of events following Acute Kidney Injury (AKI) e-alert. Following an extensive, non-systematic literature search, we used a modified Delphi process to reach consensus regarding several aspects of the utilization of AKI e-alerts. Topics discussed in this workgroup included progress in evidence base practices, the characteristics of an optimal e-alert, the measures of efficacy and effectiveness, and finally what responses would be considered best practices following AKI e-alerts. Authors concluded that the current evidence for e-alert system efficacy, although growing, remains insufficient. Technology and human-related factors were found to be crucial elements of any future investigation or implementation of such tools. The group also concluded that implementation of such systems should not be done without a vigorous plan to evaluate the efficacy and effectiveness of e-alerts. Efficacy and effectiveness of e-alerts should be measured by context-specific process and patient outcomes. Finally, the group made several suggestions regarding the clinical decision support that should be considered following successful e-alert implementation. This paper reflects the findings of a non-systematic review and expert opinion. We recommend implementation of the findings of this workgroup report for use of AKI e-alerts.

  11. Warning Alert HITL Experiment Results

    NASA Technical Reports Server (NTRS)

    Monk, Kevin J.; Ferm, Lisa; Roberts, Zach

    2018-01-01

    Minimum Operational Performance Standards (MOPS) are being developed to support the integration of Unmanned Aircraft Systems (UAS) in the National Airspace (NAS). Input from subject matter experts and multiple research studies have informed display requirements for Detect-and-Avoid (DAA) systems aimed at supporting timely and appropriate pilot responses to collision hazards. Phase 1 DAA MOPS alerting is designed to inform pilots if an avoidance maneuver is necessary; the two highest alert levels - caution and warning - indicate how soon pilot action is required and whether there is adequate time to coordinate with the air traffic controller (ATC). Additional empirical support is needed to clarify the extent to which warning-level alerting impacts DAA task performance. The present study explores the differential effects of the auditory and visual cues provided by the DAA Warning alert, and performance implications compared to caution-only alerting are discussed.

  12. Characterization of computer network events through simultaneous feature selection and clustering of intrusion alerts

    NASA Astrophysics Data System (ADS)

    Chen, Siyue; Leung, Henry; Dondo, Maxwell

    2014-05-01

    As computer network security threats increase, many organizations implement multiple Network Intrusion Detection Systems (NIDS) to maximize the likelihood of intrusion detection and provide a comprehensive understanding of intrusion activities. However, NIDS trigger a massive number of alerts on a daily basis. This can be overwhelming for computer network security analysts since it is a slow and tedious process to manually analyse each alert produced. Thus, automated and intelligent clustering of alerts is important to reveal the structural correlation of events by grouping alerts with common features. As the nature of computer network attacks, and therefore alerts, is not known in advance, unsupervised alert clustering is a promising approach to achieve this goal. We propose a joint optimization technique for feature selection and clustering to aggregate similar alerts and to reduce the number of alerts that analysts have to handle individually. More precisely, each identified feature is assigned a binary value, which reflects the feature's saliency. This value is treated as a hidden variable and incorporated into a likelihood function for clustering. Since computing the optimal solution of the likelihood function directly is analytically intractable, we use the Expectation-Maximisation (EM) algorithm to iteratively update the hidden variable and use it to maximize the expected likelihood. Our empirical results, using a labelled Defense Advanced Research Projects Agency (DARPA) 2000 reference dataset, show that the proposed method gives better results than the EM clustering without feature selection in terms of the clustering accuracy.

  13. Safety Alerts: An Observational Study in Portugal.

    PubMed

    Soares, Sara; Roque, Fátima; Teixeira Rodrigues, António; Figueiras, Adolfo; Herdeiro, Maria Teresa

    2015-09-01

    The information that is available when marketing authorizations are approved is limited. Pharmacovigilance has an important role during the postauthorization period, and alerts published by national authorities allow health care professionals to be informed about new data on safety profiles. This study therefore sought to analyze all safety alerts published by the Portuguese National Authority of Medicines and Health Products I.P. (INFARMED). We conducted an observational study of all alerts published on the INFARMED website from January 2002 through December 2014. From the data included in the alerts, the following information was abstracted: active substance name (and trade name), event that led to the alert, and the resulting safety measures. Active substances were classified according to the Anatomical Therapeutic Chemical (ATC) code. A total of 562 alerts were published, and 304 were eligible for inclusion. The musculoskeletal system was the ATC code with more alerts (n = 53), followed by the nervous system (n = 42). Communication of the information and recommendations to the health care professionals and the public in general was the most frequent safety measure (n = 128), followed by changes in the Summary of the Product Characteristics and package information leaflet (n = 66). During the study period, 26 marketing authorizations were temporarily suspended and 10 were revoked. The knowledge of the alerts published during the postmarketing period is very useful to the health care professionals for improving prescription and use of medicines and to the scientific community for the development of new researches. Copyright © 2015 Elsevier HS Journals, Inc. All rights reserved.

  14. Improving the Quality of Alerts and Predicting Intruder's Next Goal with Hidden Colored Petri-Net

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, Dong; Frincke, Deb A.

    2006-06-22

    Intrusion detection systems (IDS) often provide poor quality alerts, which are insufficient to support rapid identification of ongoing attacks or predict an intruder’s next likely goal. In this paper, we propose a novel approach to alert post-processing and correlation, the Hidden Colored Petri-Net (HCPN). Different from most other alert correlation methods, our approach treats the alert correlation problem as an inference problem rather than a filter problem. Our approach assumes that the intruder’s actions are unknown to the IDS and can be inferred only from the alerts generated by the IDS sensors. HCPN can describe the relationship between different stepsmore » carried out by intruders, model observations (alerts) and transitions (actions) separately, and associate each token element (system state) with a probability (or confidence). The model is an extension to Colored Petri-Net (CPN) .It is so called “hidden” because the transitions (actions) are not directly observable but can be inferred by looking through the observations (alerts). These features make HCPN especially suitable for discovering intruders’ actions from their partial observations (alerts,) and predicting intruders’ next goal. Our experiments on DARPA evaluation datasets and the attack scenarios from the Grand Challenge Problem (GCP) show that HCPN has promise as a way to reducing false positives and negatives, predicting intruder’s next possible action, uncovering intruders’ intrusion strategies after the attack scenario has happened, and providing confidence scores.« less

  15. Expert Design Advisor

    DTIC Science & Technology

    1990-10-01

    to economic, technological, spatial or logistic concerns, or involve training, man-machine interfaces, or integration into existing systems. Once the...probabilistic reasoning, mixed analysis- and simulation-oriented, mixed computation- and communication-oriented, nonpreemptive static priority...scheduling base, nonrandomized, preemptive static priority scheduling base, randomized, simulation-oriented, and static scheduling base. The selection of both

  16. Maximizing Trust in the Wireless Emergency Alerts (WEA) Service

    DTIC Science & Technology

    2014-02-01

    Homeland Security under Contract No. FA8721-05-C-0003 with Carnegie Mellon University for the operation of the Software En - gineering Institute, a...AOs will protect their alert-generating systems from misuse. A compro- mised alert-generating system could overload the IPAWS-OPEN message validation...greater accessibility, such as accessing the WEA service re- motely from the scene of an incident. Although we are currently unaware of any alerting

  17. Coordinated Displays to Assist Cyber Defenders

    DTIC Science & Technology

    2016-09-23

    suspicious activity, such as the occurrence of a network event that is similar to a known attack signature, the system generates an alert which is then...presented to a human computer network defense analyst, or more succinctly, a network analyst, who must evaluate the veracity of that alert . To...display and select an alert to investigate further. Though alerts generally include some information about the nature of a potential threat, the

  18. The Zwicky Transient Facility Public Alert Stream

    NASA Astrophysics Data System (ADS)

    Masci, F.; Kulkarni, S. R.; Graham, M.; Prince, T.; Helou, G.

    2018-06-01

    The Zwicky Transient Facility (ZTF; ATel #11266) announces the start of public alerts. These alerts will originate from the ZTF public surveys (Bellm & Kulkarni 2017; Nature Astronomy 1, 71) as described at www.ztf.caltech.edu/page/msip Alerts are generated by the ZTF Science Data System housed at IPAC-Caltech (www.ipac.caltech.edu) using a realtime image-subtraction pipeline (Masci et al. 2018; www.ztf.caltech.edu/page/technical).

  19. Alertness function of thalamus in conflict adaptation.

    PubMed

    Wang, Xiangpeng; Zhao, Xiaoyue; Xue, Gui; Chen, Antao

    2016-05-15

    Conflict adaptation reflects the ability to improve current conflict resolution based on previously experienced conflict, which is crucial for our goal-directed behaviors. In recent years, the roles of alertness are attracting increasing attention when discussing the generation of conflict adaptation. However, due to the difficulty of manipulating alertness, very limited progress has been made in this line. Inspired by that color may affect alertness, we manipulated background color of experimental task and found that conflict adaptation significantly presented in gray and red backgrounds but did not in blue background. Furthermore, behavioral and functional magnetic resonance imaging results revealed that the modulation of color on conflict adaptation was implemented through changing alertness level. In particular, blue background eliminated conflict adaptation by damping the alertness regulating function of thalamus and the functional connectivity between thalamus and inferior frontal gyrus (IFG). In contrast, in gray and red backgrounds where alertness levels are typically high, the thalamus and the right IFG functioned normally and conflict adaptations were significant. Therefore, the alertness function of thalamus is determinant to conflict adaptation, and thalamus and right IFG are crucial nodes of the neural circuit subserving this ability. Present findings provide new insights into the neural mechanisms of conflict adaptation. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Promoting Safety in Hypnosis: A Clinical Instrument for the Assessment of Alertness.

    PubMed

    Howard, Hedy A

    2017-04-01

    Hypnosis has long demonstrated its power to facilitate various approaches to psychotherapy. Like other potent modalities, hypnosis may produce unwanted effects. Although its negative sequelae are usually mild and transient, more serious complications may occur. Recently, attention has been drawn to the powerful role of failures of dehypnosis or alerting/realerting in producing unwanted effects. Traditionally, alerting has been viewed as a relatively uncomplicated process that requires little more than the simple suggestion that the subject will return or awaken from trance, and exiting from trance has generally been considered the cessation of the phenomena suggested during induction and thereafter. Newer findings challenge these assumptions and suggest that restoring the subject to a prehypnotic baseline level of alertness is of equal or greater importance. Here, I describe the Howard Alertness Scale (HAS), with which subjects can be made aware of their baseline levels of alertness to help them understand the unique ways that their trance states differ from their normal alert states, and assess and measure their subjective perception of alertness before and after hypnosis. Furthermore, regular use of the HAS holds potential to enhance both the therapeutic alliance and the patient's sense of safety and mastery. The development and use of the HAS is discussed along with three vignettes illustrating its clinical application.

  1. [Detection of Brucella with an automatic hemoculture system: Bact/Alert].

    PubMed

    Casas, J; Partal, Y; Llosá, J; Leiva, J; Navarro, J M; de la Rosa, M

    1994-12-01

    The ability of in vitro and in vivo detection of Brucella spp. with the Bact/Alert system was studied. Three strains of Brucella melitensis and two of Brucella abortus were used. Different dilutions of the five strains were performed in trypticase soy broth (TSB), achieving concentrations of 1 cfu/ml, 5 cfu/ml, 10 cfu/ml and 100 cfu/ml. Ten ml of each dilution and strain were inoculated into 5 aerobic bottles Bact/Alert and 5 biphasic Hemóline bottles. Furthermore, over a 9 month period, 8,216 bottles of Bact/Alert bottles from hospitalized patients and from the emergency department were processed in the authors' laboratory. The mean detection time for Brucella growth was from 2 to 3 days with the Bact/Alert system, and 14 days in the biphasic bottles. Former bottles processed in the authors' laboratory, 11 aerobic bottles belonged to 5 patients in whom brucelosis was confirmed by bloodculture. The Bact/Alert system detected Brucella melitensis in only on bottle at 2.9 days of incubation. In 7 bottles Bact/Alert detected B. melitensis by a blind pass of these bottles at 10 to 20 days of incubation. These results suggest that the Bact/Alert system does not totally solve the diagnosis of brucellosis. Blind passes of the bloodcultures are required.

  2. Duration Dependent Effect of Static Stretching on Quadriceps and Hamstring Muscle Force.

    PubMed

    Alizadeh Ebadi, Leyla; Çetin, Ebru

    2018-03-13

    The aim of this study was to determine the acute effect of static stretching on hamstring and quadriceps muscles' isokinetic strength when applied for various durations to elite athletes, to investigate the effect of different static stretching durations on isokinetic strength, and finally to determine the optimal stretching duration. Fifteen elite male athletes from two different sport branches (10 football and five basketball) participated in this study. Experimental protocol was designed as 17 repetitive static stretching exercises for hamstring and quadriceps muscle groups according to the indicated experimental protocols; ((A) 5 min jogging; (B) 5 min jogging followed by 15 s static stretching; (C) 5 min jogging followed by 30 s static stretching; (D) 5 min jogging, followed by static stretching for 45 s). Immediately after each protocol, an isokinetic strength test consisting of five repetitions at 60°/s speed and 20 repetitions at 180°/s speed was recorded for the right leg by the Isomed 2000 device. Friedman variance analysis test was employed for data analysis. According to the analyzes, it was observed that 5 min jogging and 15 s stretching exercises increased the isokinetic strength, whereas 30 and 45 s stretching exercises caused a decrease.

  3. Duration Dependent Effect of Static Stretching on Quadriceps and Hamstring Muscle Force

    PubMed Central

    Çetin, Ebru

    2018-01-01

    The aim of this study was to determine the acute effect of static stretching on hamstring and quadriceps muscles’ isokinetic strength when applied for various durations to elite athletes, to investigate the effect of different static stretching durations on isokinetic strength, and finally to determine the optimal stretching duration. Fifteen elite male athletes from two different sport branches (10 football and five basketball) participated in this study. Experimental protocol was designed as 17 repetitive static stretching exercises for hamstring and quadriceps muscle groups according to the indicated experimental protocols; ((A) 5 min jogging; (B) 5 min jogging followed by 15 s static stretching; (C) 5 min jogging followed by 30 s static stretching; (D) 5 min jogging, followed by static stretching for 45 s). Immediately after each protocol, an isokinetic strength test consisting of five repetitions at 60°/s speed and 20 repetitions at 180°/s speed was recorded for the right leg by the Isomed 2000 device. Friedman variance analysis test was employed for data analysis. According to the analyzes, it was observed that 5 min jogging and 15 s stretching exercises increased the isokinetic strength, whereas 30 and 45 s stretching exercises caused a decrease.

  4. The effect of happiness and sadness on alerting, orienting, and executive attention.

    PubMed

    Finucane, Anne M; Whiteman, Martha C; Power, Mick J

    2010-05-01

    According to the attention network approach, attention is best understood in terms of three functionally and neuroanatomically distinct networks-alerting, orienting, and executive attention. An important question is whether the experience of emotion differentially influences the efficiency of these networks. This study examines 180 participants were randomly assigned to a happy, sad, or control condition and undertook a modified version of the Attention Network Test. The results showed no effect of happiness or sadness on alerting, orienting, or executive attention. However, sad participants showed reduced intrinsic alertness. This suggests that sadness reduces general alertness rather than impairing the efficiency of specific attention networks.

  5. Lessons from Hawaii: A Blessing in Disguise.

    PubMed

    Deitchman, Scott; Dallas, Cham E; Burkle, Frederick

    2018-03-20

    On January 13, 2018, Hawaii experienced an erroneous alert that falsely warned of an imminent ballistic missile strike. Rather than focus on the inconvenience caused by the false alert, we used reporting of the event to identify the missing elements that would characterize a system that could save lives by alerting and informing the public in a nuclear detonation. These include warnings that contain essential information rather than directing recipients to secondary sources; a system that issues alerts directly from federal agencies that will have the earliest warning; a robust multimodal alerting system that can deliver messages before and after the detonation; and swift activation of federal agencies immediately upon warning.

  6. The ESA FELYX High Resolution Diagnostic Data Set System Design and Implementation

    NASA Astrophysics Data System (ADS)

    Taberner, M.; Shutler, J.; Walker, P.; Poulter, D.; Piolle, J.-F.; Donlon, C.; Guidetti, V.

    2013-10-01

    Felyx is currently under development and is the latest evolution of a generalised High Resolution Diagnostic Data Set system funded by ESA. It draws on previous prototype developments and experience in the GHRSST, Medspiration, GlobColour and GlobWave projects. In this paper, we outline the design and implementation of the system, and illustrate using the Ocean Colour demonstration activities. Felyx is fundamentally a tool to facilitate the analysis of EO data: it is being developed by IFREMER, PML and Pelamis. It will be free software written in python and javascript. The aim is to provide Earth Observation data producers and users with an opensource, flexible and reusable tool to allow the quality and performance of data streams from satellite, in situ and model sources to be easily monitored and studied. New to this project, is the ability to establish and incorporate multi-sensor match-up database capabilities. The systems will be deployable anywhere and even include interaction mechanisms between the deployed instances. The primary concept of Felyx is to work as an extraction tool. It allows for the extraction of subsets of source data over predefined target areas(which can be static or moving). These data subsets, and associated metrics, can then be accessed by users or client applications either as raw files or through automatic alerts. These data can then be used to generate periodic reports or be used for statistical analysis and visualisation through a flexible web interface. Felyx can be used for subsetting, the generation of statistics, the generation of reports or warnings/alerts, and in-depth analyses, to name a few. There are many potential applications but important uses foreseen are: * monitoring and assessing the quality of Earth observations (e.g. satellite products and time series) through statistical analysis and/or comparison with other data sources * assessing and inter-comparing geophysical inversion algorithms * observing a given phenomenon, collecting and cumulating various parameters over a defined area * crossing different sources of data for synergy applications The services provided by felyx will be generic, deployable at users own premises, and flexible allowing the integration and development of any kind of parameters. Users will be able to operate their own felyx instance at any location, on datasets and parameters of their own interest, and the various instances will be able to interact with each other, creating a web of felyx systems enabling aggregation and cross comparison of miniProds and metrics from multiple sources. Initially two instances will be operated simultaneously during a 6 months demonstration phase, at IFREMER - on sea surface temperature and ocean waves datasets - and PML - on ocean colour.

  7. 75 FR 67201 - Flightcrew Alerting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-02

    ... airplanes concerning flightcrew alerting. These standards update definitions, prioritization, color... addressed regulations regarding definitions, prioritization, color requirements, and performance for... proposal: Reserving and limiting the use of alerting colors red, amber, or yellow on the flight deck...

  8. The Three-item ALERT-B Questionnaire Provides a Validated Screening Tool to Detect Chronic Gastrointestinal Symptoms after Pelvic Radiotherapy in Cancer Survivors.

    PubMed

    Taylor, S; Byrne, A; Adams, R; Turner, J; Hanna, L; Staffurth, J; Farnell, D; Sivell, S; Nelson, A; Green, J

    2016-10-01

    Although pelvic radiotherapy is an effective treatment for various malignancies, around half of patients develop significant gastrointestinal problems. These symptoms often remain undetected, despite the existence of effective treatments. This study developed and refined a simple screening tool to detect common gastrointestinal symptoms in outpatient clinics. These symptoms have a significant effect on quality of life. This tool will increase detection rates and so enable access to specialist gastroenterologists, which will in turn lead to improved symptom control and quality of life after treatment. A literature review and expert consensus meeting identified four items for the ALERT-B (Assessment of Late Effects of RadioTherapy - Bowel) screening tool. ALERT-B was face tested for its usability and acceptability using cognitive interviews with 12 patients experiencing late gastrointestinal symptoms after pelvic radiotherapy. Thematic analysis and probe category were used to analyse interview transcripts. Interview data were presented to a group of experts to agree on the final content and format of the tool. ALERT-B was assessed for reliability and tested for validity against the Gastrointestinal Symptom Rating Scale in a clinical study (EAGLE). Overall, the tool was found to be acceptable in terms of wording, response format and completion time. Participant-reported experiences, including lifestyle modifications and the psychological effect of the symptoms, led to further modifications of the tool. The refined tool includes three questions covering rectal bleeding, incontinence, nocturnal bowel movements and impact on quality of life, including mood, relationships and socialising. ALERT-B was successfully validated against the Gastrointestinal Symptom Rating Scale in the EAGLE study with the tool shown broadly to be internally consistent (Cronbach's α = 0.61 and all item-subscale correlation [Spearman] coefficients are > 0.6). The ALERT-B screening tool can be used in clinical practice to improve post-treatment supportive care by triggering the clinical assessment of patients suitable for referral to a gastroenterologist. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  9. Behavior of Cackling Canada Geese during brood rearing

    USGS Publications Warehouse

    Fowler, Ada C.; Ely, Craig R.

    1997-01-01

    We studied behavior of Cackling Canada Goose (Branta canadensis minima, cacklers) broods between 1992 and 1996 on the Yukon Delta National Wildlife Refuge in western Alaska. An increase in time spent foraging by goslings during our study was weakly correlated with an increase in the size of the local breeding population. Amount of time spent feeding by adults and goslings increased throughout the brood rearing period. Overall, goslings spent more time feeding than either adult females or males, and adult males spent the most time alert. Time alert varied among brood rearing areas and increased with brood size, but there was no variation in time spent alert among years. Increases in feeding or alert behaviors were at a cost to time spent in all other behaviors. We suggest that there is not a simple trade-off between feeding and alert behavior in cacklers, but instead that time spent feeding and alert are optimized against all other behaviors. We suggest that forage quality and availability determines the amount of time spent feeding, whereas the threat of predation or disturbance determines the amount of time spent alert.

  10. Visualization techniques for computer network defense

    NASA Astrophysics Data System (ADS)

    Beaver, Justin M.; Steed, Chad A.; Patton, Robert M.; Cui, Xiaohui; Schultz, Matthew

    2011-06-01

    Effective visual analysis of computer network defense (CND) information is challenging due to the volume and complexity of both the raw and analyzed network data. A typical CND is comprised of multiple niche intrusion detection tools, each of which performs network data analysis and produces a unique alerting output. The state-of-the-practice in the situational awareness of CND data is the prevalent use of custom-developed scripts by Information Technology (IT) professionals to retrieve, organize, and understand potential threat events. We propose a new visual analytics framework, called the Oak Ridge Cyber Analytics (ORCA) system, for CND data that allows an operator to interact with all detection tool outputs simultaneously. Aggregated alert events are presented in multiple coordinated views with timeline, cluster, and swarm model analysis displays. These displays are complemented with both supervised and semi-supervised machine learning classifiers. The intent of the visual analytics framework is to improve CND situational awareness, to enable an analyst to quickly navigate and analyze thousands of detected events, and to combine sophisticated data analysis techniques with interactive visualization such that patterns of anomalous activities may be more easily identified and investigated.

  11. Slope Stability Analysis In Seismic Areas Of The Northern Apennines (Italy)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lo Presti, D.; Fontana, T.; Marchetti, D.

    2008-07-08

    Several research works have been published on the slope stability in the northern Tuscany (central Italy) and particularly in the seismic areas of Garfagnana and Lunigiana (Lucca and Massa-Carrara districts), aimed at analysing the slope stability under static and dynamic conditions and mapping the landslide hazard. In addition, in situ and laboratory investigations are available for the study area, thanks to the activities undertaken by the Tuscany Seismic Survey. Based on such a huge information the co-seismic stability of few ideal slope profiles have been analysed by means of Limit equilibrium method LEM - (pseudo-static) and Newmark sliding block analysismore » (pseudo-dynamic). The analysis--results gave indications about the most appropriate seismic coefficient to be used in pseudo-static analysis after establishing allowable permanent displacement. Such indications are commented in the light of the Italian and European prescriptions for seismic stability analysis with pseudo-static approach. The stability conditions, obtained from the previous analyses, could be used to define microzonation criteria for the study area.« less

  12. Visual Alert System

    NASA Technical Reports Server (NTRS)

    1985-01-01

    A visual alert system resulted from circuitry developed by Applied Cybernetics Systems for Langley as part of a space related telemetry system. James Campman, Applied Cybernetics president, left the company and founded Grace Industries, Inc. to manufacture security devices based on the Langley technology. His visual alert system combines visual and audible alerts for hearing impaired people. The company also manufactures an arson detection device called the electronic nose, and is currently researching additional applications of the NASA technology.

  13. Outlier Detection for Patient Monitoring and Alerting

    PubMed Central

    Hauskrecht, Milos; Batal, Iyad; Valko, Michal; Visweswaran, Shyam; Cooper, Gregory F.; Clermont, Gilles

    2012-01-01

    We develop and evaluate a data-driven approach for detecting unusual (anomalous) patient-management decisions using past patient cases stored in electronic health records (EHRs). Our hypothesis is that a patient-management decision that is unusual with respect to past patient care may be due to an error and that it is worthwhile to generate an alert if such a decision is encountered. We evaluate this hypothesis using data obtained from EHRs of 4,486 post-cardiac surgical patients and a subset of 222 alerts generated from the data. We base the evaluation on the opinions of a panel of experts. The results of the study support our hypothesis that the outlier-based alerting can lead to promising true alert rates. We observed true alert rates that ranged from 25% to 66% for a variety of patient-management actions, with 66% corresponding to the strongest outliers. PMID:22944172

  14. Auditory motion-specific mechanisms in the primate brain

    PubMed Central

    Baumann, Simon; Dheerendra, Pradeep; Joly, Olivier; Hunter, David; Balezeau, Fabien; Sun, Li; Rees, Adrian; Petkov, Christopher I.; Thiele, Alexander; Griffiths, Timothy D.

    2017-01-01

    This work examined the mechanisms underlying auditory motion processing in the auditory cortex of awake monkeys using functional magnetic resonance imaging (fMRI). We tested to what extent auditory motion analysis can be explained by the linear combination of static spatial mechanisms, spectrotemporal processes, and their interaction. We found that the posterior auditory cortex, including A1 and the surrounding caudal belt and parabelt, is involved in auditory motion analysis. Static spatial and spectrotemporal processes were able to fully explain motion-induced activation in most parts of the auditory cortex, including A1, but not in circumscribed regions of the posterior belt and parabelt cortex. We show that in these regions motion-specific processes contribute to the activation, providing the first demonstration that auditory motion is not simply deduced from changes in static spatial location. These results demonstrate that parallel mechanisms for motion and static spatial analysis coexist within the auditory dorsal stream. PMID:28472038

  15. Does Intellectual Property Restrict Output? An Analysis of Pharmaceutical Markets*

    PubMed Central

    Lakdawalla, Darius; Philipson, Tomas

    2013-01-01

    Standard normative analysis of intellectual property focuses on the balance between incentives for research and the static welfare costs of reduced price-competition from monopoly. However, static welfare loss from patents is not universal. While patents restrict price competition, they may also provide static welfare benefits by improving incentives for marketing, which is a form of non-price competition. We show theoretically how stronger marketing incentives mitigate, and can even offset, the static costs of monopoly pricing. Empirical analysis in the pharmaceutical industry context suggests that, in the short-run, patent expirations reduce consumer welfare as a result of decreased marketing effort. In the long-run, patent expirations do benefit consumers, but by 30% less than would be implied by the reduction in price alone. The social value of monopoly marketing to consumers alone is roughly on par with its costs to firms. PMID:25221349

  16. Does Intellectual Property Restrict Output? An Analysis of Pharmaceutical Markets.

    PubMed

    Lakdawalla, Darius; Philipson, Tomas

    2012-02-01

    Standard normative analysis of intellectual property focuses on the balance between incentives for research and the static welfare costs of reduced price-competition from monopoly. However, static welfare loss from patents is not universal. While patents restrict price competition, they may also provide static welfare benefits by improving incentives for marketing, which is a form of non -price competition. We show theoretically how stronger marketing incentives mitigate, and can even offset, the static costs of monopoly pricing. Empirical analysis in the pharmaceutical industry context suggests that, in the short-run, patent expirations reduce consumer welfare as a result of decreased marketing effort. In the long-run, patent expirations do benefit consumers, but by 30% less than would be implied by the reduction in price alone. The social value of monopoly marketing to consumers alone is roughly on par with its costs to firms.

  17. Identification of potentially emerging food safety issues by analysis of reports published by the European Community's Rapid Alert System for Food and Feed (RASFF) during a four-year period.

    PubMed

    Kleter, G A; Prandini, A; Filippi, L; Marvin, H J P

    2009-05-01

    The SAFE FOODS project undertakes to design a new approach towards the early identification of emerging food safety hazards. This study explored the utility of notifications filed through RASFF, the European Commission's Rapid Alert System for Food and Feed, to identify emerging trends in food safety issues. RASFF information and alert notifications published in the four-year period of July 2003-June 2007 were assigned to categories of products and hazards. For chronological trend analysis, a basic time unit of three months was chosen. Data within each hazard category were analyzed for chronological trends, relationships between product and hazard categories, regions of origin, and countries filing the notifications. Conspicuous trends that were observed included a rise in the incidence of food contact substances, particularly 2-isopropyl-thioxanthone, as well as of chemical substances migrating from utensils and fraud-related issues. Temporary increases were noted in the incidences of the unauthorized dye Para Red, genetically modified organisms, the pesticide isophenfos-methyl, and herring worm, Anisakis simplex. National and European authorities themselves have signaled these conspicuous trends and taken measures. It is recommended to add complementary data to RASFF data, including safety assessments, risk management measures, background data on hazards and surveillance patterns, for a holistic approach towards early identification of emerging hazards.

  18. Automatic Estimation of Verified Floating-Point Round-Off Errors via Static Analysis

    NASA Technical Reports Server (NTRS)

    Moscato, Mariano; Titolo, Laura; Dutle, Aaron; Munoz, Cesar A.

    2017-01-01

    This paper introduces a static analysis technique for computing formally verified round-off error bounds of floating-point functional expressions. The technique is based on a denotational semantics that computes a symbolic estimation of floating-point round-o errors along with a proof certificate that ensures its correctness. The symbolic estimation can be evaluated on concrete inputs using rigorous enclosure methods to produce formally verified numerical error bounds. The proposed technique is implemented in the prototype research tool PRECiSA (Program Round-o Error Certifier via Static Analysis) and used in the verification of floating-point programs of interest to NASA.

  19. AMON: Transition to real-time operations

    NASA Astrophysics Data System (ADS)

    Cowen, D. F.; Keivani, A.; Tešić, G.

    2016-04-01

    The Astrophysical Multimessenger Observatory Network (AMON) will link the world's leading high-energy neutrino, cosmic-ray, gamma-ray and gravitational wave observatories by performing real-time coincidence searches for multimessenger sources from observatories' subthreshold data streams. The resulting coincidences will be distributed to interested parties in the form of electronic alerts for real-time follow-up observation. We will present the science case, design elements, current and projected partner observatories, status of the AMON project, and an initial AMON-enabled analysis. The prototype of the AMON server has been online since August 2014 and processing archival data. Currently, we are deploying new high-uptime servers and will be ready to start issuing alerts as early as winter 2015/16.

  20. Field and laboratory comparison of the sensitivity and reliability of cocaine detection on currency using chemical sensors, humans, K-9s, and SPME/GC/MS/MS analysis

    NASA Astrophysics Data System (ADS)

    Furton, Kenneth G.; Hsu, Ya-Li; Luo, Tien-Ying; Norelus, Arnold; Rose, Stefan

    1999-02-01

    Reports that money in general circulation is contaminated with cocaine have resulted in contaminated money theories purporting that any person carrying currency could potentially initiate a drug dog alert. Field tests on dozens of different drug detector dogs with widely varying breeds, ages and training regimes show a consistent threshold level of 1 - 10 (mu) g of methyl benzoate spiked along with cocaine on U.S. currency or 0.1 - 1 ng/sec methyl benzoate diffusion required to initiate an alert. No other substance studied to data has initiated consistent responses by the drug dogs studied.

  1. Auditory decision aiding in supervisory control of multiple unmanned aerial vehicles.

    PubMed

    Donmez, Birsen; Cummings, M L; Graham, Hudson D

    2009-10-01

    This article is an investigation of the effectiveness of sonifications, which are continuous auditory alerts mapped to the state of a monitored task, in supporting unmanned aerial vehicle (UAV) supervisory control. UAV supervisory control requires monitoring a UAV across multiple tasks (e.g., course maintenance) via a predominantly visual display, which currently is supported with discrete auditory alerts. Sonification has been shown to enhance monitoring performance in domains such as anesthesiology by allowing an operator to immediately determine an entity's (e.g., patient) current and projected states, and is a promising alternative to discrete alerts in UAV control. However, minimal research compares sonification to discrete alerts, and no research assesses the effectiveness of sonification for monitoring multiple entities (e.g., multiple UAVs). The authors conducted an experiment with 39 military personnel, using a simulated setup. Participants controlled single and multiple UAVs and received sonifications or discrete alerts based on UAV course deviations and late target arrivals. Regardless of the number of UAVs supervised, the course deviation sonification resulted in reactions to course deviations that were 1.9 s faster, a 19% enhancement, compared with discrete alerts. However, course deviation sonifications interfered with the effectiveness of discrete late arrival alerts in general and with operator responses to late arrivals when supervising multiple vehicles. Sonifications can outperform discrete alerts when designed to aid operators to predict future states of monitored tasks. However, sonifications may mask other auditory alerts and interfere with other monitoring tasks that require divided attention. This research has implications for supervisory control display design.

  2. 14 CFR 23.785 - Seats, berths, litters, safety belts, and shoulder harnesses.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... combination of structural analysis and static load tests to limit load; or (3) Static load tests to ultimate... OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY... resulting from the ultimate static load factors prescribed in § 23.561(b)(2) of this part. Each occupant...

  3. 14 CFR 23.785 - Seats, berths, litters, safety belts, and shoulder harnesses.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... combination of structural analysis and static load tests to limit load; or (3) Static load tests to ultimate... OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY... resulting from the ultimate static load factors prescribed in § 23.561(b)(2) of this part. Each occupant...

  4. 14 CFR 23.785 - Seats, berths, litters, safety belts, and shoulder harnesses.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... combination of structural analysis and static load tests to limit load; or (3) Static load tests to ultimate... OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY... resulting from the ultimate static load factors prescribed in § 23.561(b)(2) of this part. Each occupant...

  5. 14 CFR 23.785 - Seats, berths, litters, safety belts, and shoulder harnesses.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... combination of structural analysis and static load tests to limit load; or (3) Static load tests to ultimate... OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY... resulting from the ultimate static load factors prescribed in § 23.561(b)(2) of this part. Each occupant...

  6. 14 CFR 23.785 - Seats, berths, litters, safety belts, and shoulder harnesses.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... combination of structural analysis and static load tests to limit load; or (3) Static load tests to ultimate... OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY... resulting from the ultimate static load factors prescribed in § 23.561(b)(2) of this part. Each occupant...

  7. 47 CFR 10.410 - Prioritization.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Prioritization. 10.410 Section 10.410 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Alert Message Requirements § 10.410 Prioritization. A Participating CMS Provider is required to transmit Presidential Alerts...

  8. 75 FR 19559 - Public Safety and Homeland Security Bureau Seeks Informal Comment Regarding Revisions to the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-15

    ..., cell phones and electronic highway signs. CAP will also allow an alert initiator to send alerts... CAP-formatted alerts delivered via any new delivery systems, whether wireline, internet, satellite, or...

  9. Alarms based on real-time sensor glucose values alert patients to hypo- and hyperglycemia: the guardian continuous monitoring system.

    PubMed

    Bode, Bruce; Gross, Kenneth; Rikalo, Nancy; Schwartz, Sherwyn; Wahl, Timothy; Page, Casey; Gross, Todd; Mastrototaro, John

    2004-04-01

    The purposes of this study were to demonstrate the accuracy and effectiveness of the Guardian Continuous Monitoring System (Medtronic MiniMed, Northridge, California) and to demonstrate that the application of real-time alarms to continuous monitoring alerts users to hypo and hyperglycemia and reduces excursions in people with diabetes. A total of 71 subjects with type 1 diabetes, mean hemoglobin A1c of 7.6 +/- 1.1%, age 44.0 +/- 11.4 years, and duration of diabetes 23.6 +/- 10.6 years were enrolled in this two-period, randomized, multicenter study. Subjects were randomized into either an Alert group or a Control group. The accuracy of the Guardian was evaluated by treating the study data as a single-sample correlational design. Effectiveness of the Guardian alerts was evaluated by comparing the Alert group with the Control group. The mean (median) absolute relative error between home blood glucose meter readings and sensor values was 21.3% (17.3%), and the Guardian, on average, read 12.8 mg/dL below the concurrent home blood glucose meter readings. The hypoglycemia alert was able to distinguished glucose values < or =70 mg/dL with 67% sensitivity, 90% specificity, and 47% false alerts. The hyperglycemia alert showed a similar ability to detect sensor values > or =250 mg/dL with 63% sensitivity, 97% specificity, and 19% false alerts. The Alert group demonstrated a median decrease in the duration of hypoglycemic excursions (-27.8 min) that was significantly greater than the median decrease in the duration of hypoglycemic excursions in the Control group (-4.5 min) (P = 0.03). A marginally significant increase in the frequency of hyperglycemic excursions (P = 0.07) between Period 1 and Period 2 was accompanied by a decrease of 9.6 min in the duration of hyperglycemic excursions in the Alert group. Glucose measurements differ between blood samples taken from the finger and interstitial fluid, especially when levels are changing rapidly; however, these results demonstrate that the Guardian is reasonably accurate while performing continuous glucose monitoring. The subjects' responses to hypoglycemia alerts resulted in a significant reduction in the duration of hypoglycemic excursions; however, overtreating hypoglycemia may have resulted in a marginally significant increase in the frequency of hyperglycemic excursions.

  10. Conditional Outlier Detection for Clinical Alerting

    PubMed Central

    Hauskrecht, Milos; Valko, Michal; Batal, Iyad; Clermont, Gilles; Visweswaran, Shyam; Cooper, Gregory F.

    2010-01-01

    We develop and evaluate a data-driven approach for detecting unusual (anomalous) patient-management actions using past patient cases stored in an electronic health record (EHR) system. Our hypothesis is that patient-management actions that are unusual with respect to past patients may be due to a potential error and that it is worthwhile to raise an alert if such a condition is encountered. We evaluate this hypothesis using data obtained from the electronic health records of 4,486 post-cardiac surgical patients. We base the evaluation on the opinions of a panel of experts. The results support that anomaly-based alerting can have reasonably low false alert rates and that stronger anomalies are correlated with higher alert rates. PMID:21346986

  11. Conditional outlier detection for clinical alerting.

    PubMed

    Hauskrecht, Milos; Valko, Michal; Batal, Iyad; Clermont, Gilles; Visweswaran, Shyam; Cooper, Gregory F

    2010-11-13

    We develop and evaluate a data-driven approach for detecting unusual (anomalous) patient-management actions using past patient cases stored in an electronic health record (EHR) system. Our hypothesis is that patient-management actions that are unusual with respect to past patients may be due to a potential error and that it is worthwhile to raise an alert if such a condition is encountered. We evaluate this hypothesis using data obtained from the electronic health records of 4,486 post-cardiac surgical patients. We base the evaluation on the opinions of a panel of experts. The results support that anomaly-based alerting can have reasonably low false alert rates and that stronger anomalies are correlated with higher alert rates.

  12. Implementation and evaluation of the Sacramento Regional Transportation Management Center Weather Alert Notification System.

    DOT National Transportation Integrated Search

    2010-08-01

    This report presents the results of an evaluation of Caltrans District 3 Regional Transportation Management Centers (RTMC) implementation of a weather alert notification system. This alert system was selected for implementation from among several ...

  13. A new method for determining a sector alert

    DOT National Transportation Integrated Search

    2008-09-29

    The Traffic Flow Management System (TFMS) currently declares an alert for any 15-minute interval in which the predicted demand exceeds the Monitor/Alert Parameter (MAP) for any airport, sector, or fix. For a sector, TFMS predicts the demand for each ...

  14. A new approach to monitoring and alerting congestion in airspace sectors

    DOT National Transportation Integrated Search

    2014-09-28

    The Federal Aviation Administration (FAA) Traffic Flow Management System (TFMS)currently declares an alert for any 15 minute interval in which the predicted demand exceeds the Monitor/Alert Parameter (MAP)for any airport, sector, or fix. For airports...

  15. Optimized molecular resolution of cross-contamination alerts in clinical mycobacteriology laboratories.

    PubMed

    Martín, Ana; Herranz, Marta; Lirola, Miguel Martínez; Fernández, Rosa Fernández; Bouza, Emilio; García de Viedma, Darío

    2008-02-14

    The phenomenon of misdiagnosing tuberculosis (TB) by laboratory cross-contamination when culturing Mycobacterium tuberculosis (MTB) has been widely reported and it has an obvious clinical, therapeutic and social impact. The final confirmation of a cross-contamination event requires the molecular identification of the same MTB strain cultured from both the potential source of the contamination and from the false-positive candidate. The molecular tool usually applied in this context is IS6110-RFLP which takes a long time to provide an answer, usually longer than is acceptable for microbiologists and clinicians to make decisions. Our purpose in this study is to evaluate a novel PCR-based method, MIRU-VNTR as an alternative to assure a rapid and optimized analysis of cross-contamination alerts. MIRU-VNTR was prospectively compared with IS6110-RFLP for clarifying 19 alerts of false positivity from other laboratories. MIRU-VNTR highly correlated with IS6110-RFLP, reduced the response time by 27 days and clarified six alerts unresolved by RFLP. Additionally, MIRU-VNTR revealed complex situations such as contamination events involving polyclonal isolates and a false-positive case due to the simultaneous cross-contamination from two independent sources. Unlike standard RFLP-based genotyping, MIRU-VNTR i) could help reduce the impact of a false positive diagnosis of TB, ii) increased the number of events that could be solved and iii) revealed the complexity of some cross-contamination events that could not be dissected by IS6110-RFLP.

  16. Nurses' response to parents' 'speaking-up' efforts to ensure their hospitalized child's safety: an attribution theory perspective.

    PubMed

    Bsharat, Sondos; Drach-Zahavy, Anat

    2017-09-01

    To understand how attribution processes (control and stability), which the nurse attributes to parental involvement in maintaining child safety, determine the nurse's response to a safety alert. Participation of parents in maintaining their child's safety is shown to reduce the incidence of and risk of clinical errors. Unless nurses respond appropriately to parents' safety alerts, this potential source of support could diminish. A 2 (controllability: high vs. low) × 2 (consistency: high vs. low) factorial design. Data were collected during the period 2013-2014 in paediatric wards. Four variants of scenarios were created corresponding to the different combinations of these variables. A total of 126 nurses read a scenario and completed self-report questionnaires measuring their response to the parent's safety alert. Additional data were collected about the manipulation check, safety norms in the ward and demographic variables. Data were analysed using analysis of variance. Results showed a main effect of stability and a significant two-way interaction effect of stability and controllability, on a nurse's tendency to help the parent and fix the safety problem. Furthermore, safety norms were significantly related to nurses' response. These findings contribute to the understanding of antecedents that affect nurses' responses to parents' speaking-up initiatives: whether nurses will reject or heed the alert. Theoretical and practical implications for promoting parents' engagement in their safety are discussed. © 2017 John Wiley & Sons Ltd.

  17. Initial Evaluation of a Conflict Detection Tool in the Terminal Area

    NASA Technical Reports Server (NTRS)

    Verma Savita Arora; Tang, Huabin; Ballinger, Deborah S.; Kozon, Thomas E.; Farrahi, Amir Hossein

    2012-01-01

    Despite the recent economic recession and its adverse impact on air travel, the Federal Aviation Administration (FAA) continues to forecast an increase in air traffic demand that may see traffic double or triple by the year 2025. Increases in air traffic will burden the air traffic management system, and higher levels of safety and efficiency will be required. The air traffic controllers primary task is to ensure separation between aircraft in their airspace and keep the skies safe. As air traffic is forecasted to increase in volume and complexity [1], there is an increased likelihood of conflicts between aircraft, which adds risk and inefficiency to air traffic management and increases controller workload. To attenuate these factors, recent ATM research has shown that air and ground-based automation tools could reduce controller workload, especially if the automation is focused on conflict detection and resolution. Conflict Alert is a short time horizon conflict detection tool deployed in the Terminal Radar Approach Control (TRACON), which has limited utility due to the high number of false alerts generated and its use of dead reckoning to predict loss of separation between aircraft. Terminal Tactical Separation Assurance Flight Environment (T-TSAFE) is a short time horizon conflict detection tool that uses both flight intent and dead reckoning to detect conflicts. Results of a fast time simulation experiment indicated that TTSAFE provided a more effective alert lead-time and generated less false alerts than Conflict Alert [2]. TSAFE was previously tested in a Human-In-The-Loop (HITL) simulation study that focused on the en route phase of flight [3]. The current study tested the T-TSAFE tool in an HITL simulation study, focusing on the terminal environment with current day operations. The study identified procedures, roles, responsibilities, information requirements and usability, with the help of TRACON controllers who participated in the experiment. Metrics such as lead alert time, alert response time, workload, situation awareness and other measures were statistically analyzed. These metrics were examined from an overall perspective and comparisons between conditions (altitude resolutions via keyboard entry vs. ADS-B entry) and controller positions (two final approach sectors and two feeder sectors) were also examined. Results of these analyses and controller feedback provided evidence of T-TSAFE s potential promise as a useful air traffic controller tool. Heuristic analysis also provided information on ways in which the T-TSAFE tool can be improved. Details of analyses results will be presented in the full paper.

  18. Clinical reasoning in the context of active decision support during medication prescribing.

    PubMed

    Horsky, Jan; Aarts, Jos; Verheul, Leonie; Seger, Diane L; van der Sijs, Heleen; Bates, David W

    2017-01-01

    Describe and analyze reasoning patterns of clinicians responding to drug-drug interaction alerts in order to understand the role of patient-specific information in the decision-making process about the risks and benefits of medication therapy. Insights could be used to inform the design of decision-support interventions. Thirty-two clinicians working with five EHRs in two countries completed sets of six medication orders each and responded to high- and low-severity drug-drug interaction alerts while verbalizing their thoughts in a standard think-aloud protocol. Tasks were recorded and analyzed to describe reasoning patterns about patient-risk assessment and strategies to avoid or mitigate it. We observed a total of 171 prescribing decisions. Clinicians actively sought to reduce risk when responding to high-severity alerts, mostly by monitoring patients and making dose adjustments (52 alerts, 40%). In contrast, they routinely left prescriptions unchanged after low-severity alerts when they felt confident that patients would tolerate the drug combination and that treatment benefits outweighed the risks (30 alerts, 71%). Clinicians used similar reasoning patterns regardless of the EHR used and differences in alert design. Clinicians conceptualized risk as a complex set of interdependent tradeoffs specific to individual patients and had a tendency not to follow advice they considered of low clinical value. Omission of patient-specific data, which was not shown in alerts or included in trigger logic, may have contributed to the constancy of reasoning and to similarities in risk-control strategies we observed despite significant differences in interface design and system function. Declining an alert suggestion was preceded by sometimes brief but often complex reasoning, prioritizing different aspects of care quality and safety, especially when the perceived risk was higher. Clinicians believed that the risk indicated in drug-drug interaction alerts needs to be interpreted as one factor in the broader context of care, specific to a patient. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  19. Using Supervised Machine Learning to Classify Real Alerts and Artifact in Online Multi-signal Vital Sign Monitoring Data

    PubMed Central

    Chen, Lujie; Dubrawski, Artur; Wang, Donghan; Fiterau, Madalina; Guillame-Bert, Mathieu; Bose, Eliezer; Kaynar, Ata M.; Wallace, David J.; Guttendorf, Jane; Clermont, Gilles; Pinsky, Michael R.; Hravnak, Marilyn

    2015-01-01

    OBJECTIVE Use machine-learning (ML) algorithms to classify alerts as real or artifacts in online noninvasive vital sign (VS) data streams to reduce alarm fatigue and missed true instability. METHODS Using a 24-bed trauma step-down unit’s non-invasive VS monitoring data (heart rate [HR], respiratory rate [RR], peripheral oximetry [SpO2]) recorded at 1/20Hz, and noninvasive oscillometric blood pressure [BP] less frequently, we partitioned data into training/validation (294 admissions; 22,980 monitoring hours) and test sets (2,057 admissions; 156,177 monitoring hours). Alerts were VS deviations beyond stability thresholds. A four-member expert committee annotated a subset of alerts (576 in training/validation set, 397 in test set) as real or artifact selected by active learning, upon which we trained ML algorithms. The best model was evaluated on alerts in the test set to enact online alert classification as signals evolve over time. MAIN RESULTS The Random Forest model discriminated between real and artifact as the alerts evolved online in the test set with area under the curve (AUC) performance of 0.79 (95% CI 0.67-0.93) for SpO2 at the instant the VS first crossed threshold and increased to 0.87 (95% CI 0.71-0.95) at 3 minutes into the alerting period. BP AUC started at 0.77 (95%CI 0.64-0.95) and increased to 0.87 (95% CI 0.71-0.98), while RR AUC started at 0.85 (95%CI 0.77-0.95) and increased to 0.97 (95% CI 0.94–1.00). HR alerts were too few for model development. CONCLUSIONS ML models can discern clinically relevant SpO2, BP and RR alerts from artifacts in an online monitoring dataset (AUC>0.87). PMID:26992068

  20. Using Supervised Machine Learning to Classify Real Alerts and Artifact in Online Multisignal Vital Sign Monitoring Data.

    PubMed

    Chen, Lujie; Dubrawski, Artur; Wang, Donghan; Fiterau, Madalina; Guillame-Bert, Mathieu; Bose, Eliezer; Kaynar, Ata M; Wallace, David J; Guttendorf, Jane; Clermont, Gilles; Pinsky, Michael R; Hravnak, Marilyn

    2016-07-01

    The use of machine-learning algorithms to classify alerts as real or artifacts in online noninvasive vital sign data streams to reduce alarm fatigue and missed true instability. Observational cohort study. Twenty-four-bed trauma step-down unit. Two thousand one hundred fifty-three patients. Noninvasive vital sign monitoring data (heart rate, respiratory rate, peripheral oximetry) recorded on all admissions at 1/20 Hz, and noninvasive blood pressure less frequently, and partitioned data into training/validation (294 admissions; 22,980 monitoring hours) and test sets (2,057 admissions; 156,177 monitoring hours). Alerts were vital sign deviations beyond stability thresholds. A four-member expert committee annotated a subset of alerts (576 in training/validation set, 397 in test set) as real or artifact selected by active learning, upon which we trained machine-learning algorithms. The best model was evaluated on test set alerts to enact online alert classification over time. The Random Forest model discriminated between real and artifact as the alerts evolved online in the test set with area under the curve performance of 0.79 (95% CI, 0.67-0.93) for peripheral oximetry at the instant the vital sign first crossed threshold and increased to 0.87 (95% CI, 0.71-0.95) at 3 minutes into the alerting period. Blood pressure area under the curve started at 0.77 (95% CI, 0.64-0.95) and increased to 0.87 (95% CI, 0.71-0.98), whereas respiratory rate area under the curve started at 0.85 (95% CI, 0.77-0.95) and increased to 0.97 (95% CI, 0.94-1.00). Heart rate alerts were too few for model development. Machine-learning models can discern clinically relevant peripheral oximetry, blood pressure, and respiratory rate alerts from artifacts in an online monitoring dataset (area under the curve > 0.87).

Top