Dynamic Simulation and Static Matching for Action Prediction: Evidence from Body Part Priming
ERIC Educational Resources Information Center
Springer, Anne; Brandstadter, Simone; Prinz, Wolfgang
2013-01-01
Accurately predicting other people's actions may involve two processes: internal real-time simulation (dynamic updating) and matching recently perceived action images (static matching). Using a priming of body parts, this study aimed to differentiate the two processes. Specifically, participants played a motion-controlled video game with…
ERIC Educational Resources Information Center
Setti, Annalisa; Borghi, Anna M.; Tessari, Alessia
2009-01-01
In this study we investigated with a priming paradigm whether uni and bimanual actions presented as primes differently affected language processing. Animals' (self-moving entities) and plants' (not self-moving entities) names were used as targets. As prime we used grasping hands, presented both as static images and videos. The results showed an…
Boettcher, Wolfgang; Dehmel, Frank; Redlin, Mathias; Miera, Oliver; Musci, Michele; Cho, Mi-Young; Photiadis, Joachim
2017-01-01
Abstract: Performing safe cardiac surgery in neonates or infants whose parents are Jehovah's Witnesses is only possible in a coordinated team approach. An unconditional prerequisite is a cardiopulmonary bypass (CPB) circuit with a very low priming volume to minimize hemodilution. In the past decade, we have developed a functional blood-sparing approach at our institution. The extracorporeal circuit was miniaturized. This had to be recently adapted, faced with a challenge associated with the switch to high-volume crystalloid cardioplegia. A filtration circuit was added. Here, we report an open heart surgery on three consecutive children of Jehovah's Witness parents with a body weight of 2.7, 4.5, and 4.8 kg, respectively. Procedures consisted of one arterial switch operation and two repairs of complete atrioventricular septal defects. Our static priming volume of less than 90 mL resulted in a nadir hematocrit during CPB of 27.7% (Hb 8.9 g/dL) in a patient which happened to have the lowest body weight of 2.7 kg. The two other patients had their lowest hematocrit at 31.4% (Hb 10.2 g/dL). The three children could be treated without any kind of transfusion of blood which had left the circulation or its extensions, in accordance with the parents' wishes, and enjoy favorable outcomes without transfusion of blood products during their entire hospital stay. PMID:28638157
Zayas, Vivian; Pandey, Gayathri; Tabak, Joshua
2017-01-01
Attitudes are not static, but constructed at the moment of the evaluation, incorporating temporary contextual influences. How do meaningful events that naturally occur within a culture, such as a national holiday, shape evaluative judgments of objects related to the holiday? We focused on evaluations of red roses and gift chocolates, which are everyday objects, but also iconic of Valentine's Day in the U.S. We reasoned that if cultural events shape evaluations, then roses and chocolates would be evaluated differently near Valentine's Day. Using a large and diverse U.S. sample, we found that as Valentine's Day neared, evaluations of roses and chocolates (but not a comparison object) were evaluated more positively. Increases in positivity of roses and chocolates covaried with their increased cultural relevance, as quantified by the volume of web search queries involving these terms. These findings provide a demonstration of naturally occurring cultural priming by which the salience of cultural events shape evaluations.
Gemini 11 prime crew during water egress training in Gulf of Mexico
NASA Technical Reports Server (NTRS)
1966-01-01
Astronauts Charles Conrad Jr. (left) and Richard F. Gordon Jr. (right), prime crew for Gemini 11 space flight, practice water egress procedures in the Gulf of Mexico. Static Article 5 was used in the training exercise. A Manned Spaceflight Center (MSC) swimmer is in the water assisting in the training.
Inferring the direction of implied motion depends on visual awareness
Faivre, Nathan; Koch, Christof
2014-01-01
Visual awareness of an event, object, or scene is, by essence, an integrated experience, whereby different visual features composing an object (e.g., orientation, color, shape) appear as an unified percept and are processed as a whole. Here, we tested in human observers whether perceptual integration of static motion cues depends on awareness by measuring the capacity to infer the direction of motion implied by a static visible or invisible image under continuous flash suppression. Using measures of directional adaptation, we found that visible but not invisible implied motion adaptors biased the perception of real motion probes. In a control experiment, we found that invisible adaptors implying motion primed the perception of subsequent probes when they were identical (i.e., repetition priming), but not when they only shared the same direction (i.e., direction priming). Furthermore, using a model of visual processing, we argue that repetition priming effects are likely to arise as early as in the primary visual cortex. We conclude that although invisible images implying motion undergo some form of nonconscious processing, visual awareness is necessary to make inferences about motion direction. PMID:24706951
Inferring the direction of implied motion depends on visual awareness.
Faivre, Nathan; Koch, Christof
2014-04-04
Visual awareness of an event, object, or scene is, by essence, an integrated experience, whereby different visual features composing an object (e.g., orientation, color, shape) appear as an unified percept and are processed as a whole. Here, we tested in human observers whether perceptual integration of static motion cues depends on awareness by measuring the capacity to infer the direction of motion implied by a static visible or invisible image under continuous flash suppression. Using measures of directional adaptation, we found that visible but not invisible implied motion adaptors biased the perception of real motion probes. In a control experiment, we found that invisible adaptors implying motion primed the perception of subsequent probes when they were identical (i.e., repetition priming), but not when they only shared the same direction (i.e., direction priming). Furthermore, using a model of visual processing, we argue that repetition priming effects are likely to arise as early as in the primary visual cortex. We conclude that although invisible images implying motion undergo some form of nonconscious processing, visual awareness is necessary to make inferences about motion direction.
Zayas, Vivian; Pandey, Gayathri; Tabak, Joshua
2017-01-01
Attitudes are not static, but constructed at the moment of the evaluation, incorporating temporary contextual influences. How do meaningful events that naturally occur within a culture, such as a national holiday, shape evaluative judgments of objects related to the holiday? We focused on evaluations of red roses and gift chocolates, which are everyday objects, but also iconic of Valentine’s Day in the U.S. We reasoned that if cultural events shape evaluations, then roses and chocolates would be evaluated differently near Valentine’s Day. Using a large and diverse U.S. sample, we found that as Valentine’s Day neared, evaluations of roses and chocolates (but not a comparison object) were evaluated more positively. Increases in positivity of roses and chocolates covaried with their increased cultural relevance, as quantified by the volume of web search queries involving these terms. These findings provide a demonstration of naturally occurring cultural priming by which the salience of cultural events shape evaluations. PMID:28373852
Bloodless surgery in a pediatric Jehovah's Witness.
Allen, Jerry; Berrios, Lindsay; Solimine, Mike; Knott-Craig, Christopher J
2013-12-01
Pediatric cardiac surgery in Jehovah's Witness patients who refuse the use of blood products remains a challenge because of the extreme hemodilution caused by priming the circuit and subsequent cardiopulmonary bypass. We report our successful strategy for reducing the prime volume for a 2-year-old Jehovah's Witness patient who required open heart surgery. We modified our conventional bypass circuit requirements for this size child by incorporating a lower prime oxygenator and reducing the size of the venous line and circuit, which decreased the circuit prime volume. We managed to reduce our initial sanguineous prime volume from 315 to 210 mL. The prime was further reduced to 160 mL by minimizing circuit length at the field and with venous prime sequestration prebypass. The postbypass hematocrit was 31%. Bloodless pediatric cardiac surgery in Jehovah's Witness patients can be performed safely. Incorporating a lower prime oxygenator into a revised circuit alleviated the need for blood transfusion and allowed us to achieve our calculated flow rate of 2.6 L/min/m2 while maintaining a hematocrit of 31%.
1987-01-01
Headquarters Services Directorate for Information Operations and Reports D) ,( /NT IS lientitra on nn Iber for hIs bh act& r, s (i0 ’F H 7 FOREWORD 500...This report provides information on the 500 contractors that received the largest dollar volume in Department of Defense (DOD) prime contract awards... report presents summary data on the 500 prime contractors receiving the largest dollar volume in Department of Defense (DOD) awards over $25,000 for
The physiological basis and clinical significance of lung volume measurements.
Lutfi, Mohamed Faisal
2017-01-01
From a physiological standpoint, the lung volumes are either dynamic or static. Both subclasses are measured at different degrees of inspiration or expiration; however, dynamic lung volumes are characteristically dependent on the rate of air flow. The static lung volumes/capacities are further subdivided into four standard volumes (tidal, inspiratory reserve, expiratory reserve, and residual volumes) and four standard capacities (inspiratory, functional residual, vital and total lung capacities). The dynamic lung volumes are mostly derived from vital capacity. While dynamic lung volumes are essential for diagnosis and follow up of obstructive lung diseases, static lung volumes are equally important for evaluation of obstructive as well as restrictive ventilatory defects. This review intends to update the reader with the physiological basis, clinical significance and interpretative approaches of the standard static lung volumes and capacities.
Conspicuity, memorability, comprehension, and priming in road hazard warning signs.
Charlton, Samuel G
2006-05-01
This study assessed driver reactions to 16 road hazard warning signs of various formats by projecting life-sized video of road scenes to drivers in a driving simulator. A range of measures, including attentional and search conspicuity, implicit and explicit recognition, dynamic and static comprehension, and sign priming were collected. Of the signs tested, road works and school warning signs were most often detected, remembered, and understood. Slippery surface warnings were associated with some of the lowest detection and comprehension rates. The effectiveness of the different formats depended on the type of hazard sign. In the case of road works warnings, a flashing variable message format was only slightly more conspicuous than the large dimension format, equal in comprehensibility, and perhaps somewhat worse in terms of memorability. For the school warnings, however, the flashing variable message format appeared to convey a greater sense of potential hazard, produced superior search conspicuity and priming, and was equal in terms of memorability and comprehensibility. The range of measures worked well as a whole with the two measures of conspicuity and the measure of static comprehension showing the greatest consistency.
Effects of Microstructural Parameters on Creep of Nickel-Base Superalloy Single Crystals
NASA Technical Reports Server (NTRS)
MacKay, Rebecca A.; Gabb, Timothy P.; Nathal, Michael V.
2013-01-01
Microstructure-sensitive creep models have been developed for Ni-base superalloy single crystals. Creep rupture testing was conducted on fourteen single crystal alloys at two applied stress levels at each of two temperatures, 982 and 1093 C. The variation in creep lives among the different alloys could be explained with regression models containing relatively few microstructural parameters. At 982 C, gamma-gamma prime lattice mismatch, gamma prime volume fraction, and initial gamma prime size were statistically significant in explaining the creep rupture lives. At 1093 C, only lattice mismatch and gamma prime volume fraction were significant. These models could explain from 84 to 94 percent of the variation in creep lives, depending on test condition. Longer creep lives were associated with alloys having more negative lattice mismatch, lower gamma prime volume fractions, and finer gamma prime sizes. The gamma-gamma prime lattice mismatch exhibited the strongest influence of all the microstructural parameters at both temperatures. Although a majority of the alloys in this study were stable with respect to topologically close packed (TCP) phases, it appeared that up to approximately 2 vol% TCP phase did not affect the 1093 C creep lives under applied stresses that produced lives of approximately 200 to 300 h. In contrast, TCP phase contents of approximately 2 vol% were detrimental at lower applied stresses where creep lives were longer. A regression model was also developed for the as-heat treated initial gamma prime size; this model showed that gamma prime solvus temperature, gamma-gamma prime lattice mismatch, and bulk Re content were all statistically significant.
Thuys, Clarke; Horton, Stephen; Bennett, Martin; Augustin, Simon
2006-01-01
Increasing perioperative haemoglobin level by reducing priming volume and maintaining a safe cardiopulmonary bypass (CPB) system is the aim of every perfusionist. In this study, we have compared the two membrane oxygenators and pump systems used for paediatric bypass at the Royal Children's Hospital on a regular basis since 1988. We looked at all patients who had the Cobe VPCML (Cobe Laboratories, Denver, CO, USA) and Terumo RX-05 (Terumo Corporation, Tokyo, Japan) oxygenators used for flows from 800 mL/min up to the maximum rated flow for the respective oxygenator from January 2002 until March 2004. The VPCML refers to using only the 0.4-m2 section of the oxygenator. The pump systems used were the Stöckert CAPS (Stöckert Instrumente GmbH, Munich, Germany) and Jostra HL 30 (Jostra AB, Lund, Sweden). Changing from the VPCML to the RX-05 resulted in a 37% reduction in priming volume. The introduction of the Jostra HL 30 with a custom-designed mast system reduced the priming volume by another 15%. This change in priming volume allowed a significant increase, from 6 to 34%, in the percentage of patients who received bloodless primes, and for those patients who received blood primes, an increase in haemoglobin (Hb) on bypass from 8.2 to 9.6 g/dL, on average.
Redlin, Matthias; Boettcher, Wolfgang; Dehmel, Frank; Cho, Mi-Young; Kukucka, Marian; Habazettl, Helmut
2017-11-01
When applying a blood-conserving approach in paediatric cardiac surgery with the aim of reducing the transfusion of homologous blood products, the decision to use blood or blood-free priming of the cardiopulmonary bypass (CPB) circuit is often based on the predicted haemoglobin concentration (Hb) as derived from the pre-CPB Hb, the prime volume and the estimated blood volume. We assessed the accuracy of this approach and whether it may be improved by using more sophisticated methods of estimating the blood volume. Data from 522 paediatric cardiac surgery patients treated with CPB with blood-free priming in a 2-year period from May 2013 to May 2015 were collected. Inclusion criteria were body weight <15 kg and available Hb data immediately prior to and after the onset of CPB. The Hb on CPB was predicted according to Fick's principle from the pre-CPB Hb, the prime volume and the patient blood volume. Linear regression analyses and Bland-Altman plots were used to assess the accuracy of the Hb prediction. Different methods to estimate the blood volume were assessed and compared. The initial Hb on CPB correlated well with the predicted Hb (R 2 =0.87, p<0.001). A Bland-Altman plot revealed little bias at 0.07 g/dL and an area of agreement from -1.35 to 1.48 g/dL. More sophisticated methods of estimating blood volume from lean body mass did not improve the Hb prediction, but rather increased bias. Hb prediction is reasonably accurate, with the best result obtained with the simplest method of estimating the blood volume at 80 mL/kg body weight. When deciding for or against blood-free priming, caution is necessary when the predicted Hb lies in a range of ± 2 g/dL around the transfusion trigger.
Effect of inlet disturbances on fan inlet noise during a static test
NASA Technical Reports Server (NTRS)
Bekofske, K. L.; Sheer, R. E., Jr.; Wang, J. C. F.
1977-01-01
Measurements of fan rotor inlet noise taken during static test situations are at variance with aircraft engine flight data. In particular, static tests generally yield a significantly higher tone at blade passage frequency than that measured during flight. To explain this discrepancy, the extent of the influence of inlet ground vortices and large-scale inlet turbulence on the forward-radiated fan noise measured at a static test facility was investigated. While such inlet disturbances were generated intentionally in an anechoic test chamber, far-field acoustic measurements and inlet flow-field hot-film mappings of a fan rotor were obtained. Experimental results indicate that the acoustic effect of such disturbances appears to be less severe for supersonic than for subsonic tip speeds. Further, a reverse flow that occurs on the exterior cowl in static test facilities appears to be an additional prime candidate for creating inlet disturbances and causing variance between flight and static acoustic data.
The Effect of Self-Referential Expectation on Emotional Face Processing
McKendrick, Mel; Butler, Stephen H.; Grealy, Madeleine A.
2016-01-01
The role of self-relevance has been somewhat neglected in static face processing paradigms but may be important in understanding how emotional faces impact on attention, cognition and affect. The aim of the current study was to investigate the effect of self-relevant primes on processing emotional composite faces. Sentence primes created an expectation of the emotion of the face before sad, happy, neutral or composite face photos were viewed. Eye movements were recorded and subsequent responses measured the cognitive and affective impact of the emotion expressed. Results indicated that primes did not guide attention, but impacted on judgments of valence intensity and self-esteem ratings. Negative self-relevant primes led to the most negative self-esteem ratings, although the effect of the prime was qualified by salient facial features. Self-relevant expectations about the emotion of a face and subsequent attention to a face that is congruent with these expectations strengthened the affective impact of viewing the face. PMID:27175487
The Effect of Self-Referential Expectation on Emotional Face Processing.
McKendrick, Mel; Butler, Stephen H; Grealy, Madeleine A
2016-01-01
The role of self-relevance has been somewhat neglected in static face processing paradigms but may be important in understanding how emotional faces impact on attention, cognition and affect. The aim of the current study was to investigate the effect of self-relevant primes on processing emotional composite faces. Sentence primes created an expectation of the emotion of the face before sad, happy, neutral or composite face photos were viewed. Eye movements were recorded and subsequent responses measured the cognitive and affective impact of the emotion expressed. Results indicated that primes did not guide attention, but impacted on judgments of valence intensity and self-esteem ratings. Negative self-relevant primes led to the most negative self-esteem ratings, although the effect of the prime was qualified by salient facial features. Self-relevant expectations about the emotion of a face and subsequent attention to a face that is congruent with these expectations strengthened the affective impact of viewing the face.
Mridha, Nilimesh; Chattaraj, Sudipta; Chakraborty, Debashis; Anand, Anjali; Aggarwal, Pramila; Nagarajan, Shantha
2016-09-01
Soil moisture stress during pod filling is a major constraint in production of chickpea (Cicer arietinum L.), a fundamentally dry land crop. We investigated effect of pre-sowing seed priming with static magnetic field (SMF) on alleviation of stress through improvement in radiation and water use efficiencies. Experiments were conducted under greenhouse and open field conditions with desi and kabuli genotypes. Seeds exposed to SMF (strength: 100 mT, exposure: 1 h) led to increase in root volume and surface area by 70% and 65%, respectively. This enabled the crop to utilize 60% higher moisture during the active growth period (78-118 days after sowing), when soil moisture became limiting. Both genotypes from treated seeds had better water utilization, biomass, and radiation use efficiencies (17%, 40%, and 26% over control). Seed pre-treatment with SMF could, therefore, be a viable option for chickpea to alleviate soil moisture stress in arid and semi-arid regions, helping in augmenting its production. It could be a viable option to improve growth and yield of chickpea under deficit soil moisture condition, as the selection and breeding program takes a decade before a tolerant variety is released. Bioelectromagnetics. 37:400-408, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
The Aachen miniaturized heart-lung machine--first results in a small animal model.
Schnoering, Heike; Arens, Jutta; Sachweh, Joerg S; Veerman, Melanie; Tolba, Rene; Schmitz-Rode, Thomas; Steinseifer, Ulrich; Vazquez-Jimenez, Jaime F
2009-11-01
Congenital heart surgery most often incorporates extracorporeal circulation. Due to foreign surface contact and the administration of foreign blood in many children, inflammatory response and hemolysis are important matters of debate. This is particularly an issue in premature and low birth-weight newborns. Taking these considerations into account, the Aachen miniaturized heart-lung machine (MiniHLM) with a total static priming volume of 102 mL (including tubing) was developed and tested in a small animal model. Fourteen female Chinchilla Bastard rabbits were operated on using two different kinds of circuits. In eight animals, a conventional HLM with Dideco Kids oxygenator and Stöckert roller pump (Sorin group, Milan, Italy) was used, and the Aachen MiniHLM was employed in six animals. Outcome parameters were hemolysis and blood gas analysis including lactate. The rabbits were anesthetized, and a standard median sternotomy was performed. The ascending aorta and the right atrium were cannulated. After initiating cardiopulmonary bypass, the aorta was cross-clamped, and cardiac arrest was induced by blood cardioplegia. Blood samples for hemolysis and blood gas analysis were drawn before, during, and after cardiopulmonary bypass. After 1 h aortic clamp time, all animals were weaned from cardiopulmonary bypass. Blood gas analysis revealed adequate oxygenation and perfusion during cardiopulmonary bypass, irrespective of the employed perfusion system. The use of the Aachen MiniHLM resulted in a statistically significant reduced decrease in fibrinogen during cardiopulmonary bypass. A trend revealing a reduced increase in free hemoglobin during bypass in the MiniHLM group could also be observed. This newly developed Aachen MiniHLM with low priming volume, reduced hemolysis, and excellent gas transfer (O(2) and CO(2)) may reduce circuit-induced complications during heart surgery in neonates.
Cardiovascular change during encoding predicts the nonconscious mere exposure effect.
Ladd, Sandra L; Toscano, William B; Cowings, Patricia S; Gabrieli, John D E
2014-01-01
These studies examined memory encoding to determine whether the mere exposure effect could be categorized as a form of conceptual or perceptual implicit priming and, if it was not conceptual or perceptual, whether cardiovascular psychophysiology could reveal its nature. Experiment 1 examined the effects of study phase level of processing on recognition, the mere exposure effect, and word identification implicit priming. Deep relative to shallow processing improved recognition but did not influence the mere exposure effect for nonwords or word identification implicit priming for words. Experiments 2 and 3 examined the effect of study-test changes in font and orientation, respectively, on the mere exposure effect and word identification implicit priming. Different study-test font and orientation reduced word identification implicit priming but had no influence on the mere exposure effect. Experiments 4 and 5 developed and used, respectively, a cardiovascular psychophysiological implicit priming paradigm to examine whether stimulus-specific cardiovascular reactivity at study predicted the mere exposure effect at test. Blood volume pulse change at study was significantly greater for nonwords that were later preferred than for nonwords that were not preferred at test. There was no difference in blood volume pulse change for words at study that were later either identified or not identified at test. Fluency effects, at encoding or retrieval, are an unlikely explanation for these behavioral and cardiovascular findings. The relation of blood volume pulse to affect suggests that an affective process that is not conceptual or perceptual contributes to the mere exposure effect.
INTRODUCTION AND STATIC ELECTRICITY, VOLUME 1.
ERIC Educational Resources Information Center
KLAUS, DAVID J.; AND OTHERS
THIS VOLUME, PART OF A TWO-VOLUME SET, PROVIDES AUTOINSTRUCTION IN PHYSICS. THE MATERIAL COVERS UNITS ON (1) STATIC ELECTRICITY AND ELECTRICAL CHARGES, (2) COULOMB'S LAW, (3) DISTRIBUTION OF CHARGE AND FLOW OF CURRENT, (4) DIFFERENCE OF POTENTIAL, (5) BATTERIES AND CIRCUITS, (6) RESISTANCE AND RESISTORS, (7) POTENTIAL DIVIDER AND WHEATSTONE…
Static respiratory muscle work during immersion with positive and negative respiratory loading.
Taylor, N A; Morrison, J B
1999-10-01
Upright immersion imposes a pressure imbalance across the thorax. This study examined the effects of air-delivery pressure on inspiratory muscle work during upright immersion. Eight subjects performed respiratory pressure-volume relaxation maneuvers while seated in air (control) and during immersion. Hydrostatic, respiratory elastic (lung and chest wall), and resultant static respiratory muscle work components were computed. During immersion, the effects of four air-delivery pressures were evaluated: mouth pressure (uncompensated); the pressure at the lung centroid (PL,c); and at PL,c +/-0.98 kPa. When breathing at pressures less than the PL,c, subjects generally defended an expiratory reserve volume (ERV) greater than the immersed relaxation volume, minus residual volume, resulting in additional inspiratory muscle work. The resultant static inspiratory muscle work, computed over a 1-liter tidal volume above the ERV, increased from 0.23 J. l(-1), when subjects were breathing at PL,c, to 0.83 J. l(-1) at PL,c -0.98 kPa (P < 0.05), and to 1.79 J. l(-1) at mouth pressure (P < 0.05). Under the control state, and during the above experimental conditions, static expiratory work was minimal. When breathing at PL,c +0.98 kPa, subjects adopted an ERV less than the immersed relaxation volume, minus residual volume, resulting in 0.36 J. l(-1) of expiratory muscle work. Thus static inspiratory muscle work varied with respiratory loading, whereas PL,c air supply minimized this work during upright immersion, restoring lung-tissue, chest-wall, and static muscle work to levels obtained in the control state.
Fukuoka, Yoshiyuki; Poole, David C; Barstow, Thomas J; Kondo, Narihiko; Nishiwaki, Masato; Okushima, Dai; Koga, Shunsaku
2015-01-01
Novel time-resolved near-infrared spectroscopy (TR-NIRS), with adipose tissue thickness correction, was used to test the hypotheses that heavy priming exercise reduces the V̇O2 slow component (V̇O2SC) (1) by elevating microvascular [Hb] volume at multiple sites within the quadriceps femoris (2) rather than reducing the heterogeneity of muscle deoxygenation kinetics. Twelve subjects completed two 6-min bouts of heavy work rate exercise, separated by 6 min of unloaded cycling. Priming exercise induced faster overall V̇O2 kinetics consequent to a substantial reduction in the V̇O2SC (0.27 ± 0.12 vs. 0.11 ± 0.09 L·min−1, P < 0.05) with an unchanged primary V̇O2 time constant. An increased baseline for the primed bout [total (Hb + Mb)] (197.5 ± 21.6 vs. 210.7 ± 22.5 μmol L−1, P < 0.01), reflecting increased microvascular [Hb] volume, correlated significantly with the V̇O2SC reduction. At multiple sites within the quadriceps femoris, priming exercise reduced the baseline and slowed the increase in [deoxy (Hb + Mb)]. Changes in the intersite coefficient of variation in the time delay and time constant of [deoxy (Hb + Mb)] during the second bout were not correlated with the V̇O2SC reduction. These results support a mechanistic link between priming exercise-induced increase in muscle [Hb] volume and the reduced V̇O2SC that serves to speed overall V̇O2 kinetics. However, reduction in the heterogeneity of muscle deoxygenation kinetics does not appear to be an obligatory feature of the priming response. PMID:26109190
1965-07-16
S65-28459 (16 July 1965) --- Astronaut Neil A. Armstrong, command pilot for the Gemini-5 backup crew, inside the Gemini Static Article 5 spacecraft prior to water egress training in the Gulf of Mexico. The training is part of the prelaunch schedule for prime and backup crew on the Gemini-5 mission.
Strategy for Alternative Occupant Volume Testing
DOT National Transportation Integrated Search
2009-10-20
This paper describes plans for a series of quasi-static : compression tests of rail passenger equipment. These tests are : designed to evaluate the strength of the occupant volume under : static loading conditions. The research plan includes a detail...
Meijer, Tineke W H; de Geus-Oei, Lioe-Fee; Visser, Eric P; Oyen, Wim J G; Looijen-Salamon, Monika G; Visvikis, Dimitris; Verhagen, Ad F T M; Bussink, Johan; Vriens, Dennis
2017-05-01
Purpose To assess whether dynamic fluorine 18 ( 18 F) fluorodeoxyglucose (FDG) positron emission tomography (PET) has added value over static 18 F-FDG PET for tumor delineation in non-small cell lung cancer (NSCLC) radiation therapy planning by using pathology volumes as the reference standard and to compare pharmacokinetic rate constants of 18 F-FDG metabolism, including regional variation, between NSCLC histologic subtypes. Materials and Methods The study was approved by the institutional review board. Patients gave written informed consent. In this prospective observational study, 1-hour dynamic 18 F-FDG PET/computed tomographic examinations were performed in 35 patients (36 resectable NSCLCs) between 2009 and 2014. Static and parametric images of glucose metabolic rate were obtained to determine lesion volumes by using three delineation strategies. Pathology volume was calculated from three orthogonal dimensions (n = 32). Whole tumor and regional rate constants and blood volume fraction (V B ) were computed by using compartment modeling. Results Pathology volumes were larger than PET volumes (median difference, 8.7-25.2 cm 3 ; Wilcoxon signed rank test, P < .001). Static fuzzy locally adaptive Bayesian (FLAB) volumes corresponded best with pathology volumes (intraclass correlation coefficient, 0.72; P < .001). Bland-Altman analyses showed the highest precision and accuracy for static FLAB volumes. Glucose metabolic rate and 18 F-FDG phosphorylation rate were higher in squamous cell carcinoma (SCC) than in adenocarcinoma (AC), whereas V B was lower (Mann-Whitney U test or t test, P = .003, P = .036, and P = .019, respectively). Glucose metabolic rate, 18 F-FDG phosphorylation rate, and V B were less heterogeneous in AC than in SCC (Friedman analysis of variance). Conclusion Parametric images are not superior to static images for NSCLC delineation. FLAB-based segmentation on static 18 F-FDG PET images is in best agreement with pathology volume and could be useful for NSCLC autocontouring. Differences in glycolytic rate and V B between SCC and AC are relevant for research in targeting agents and radiation therapy dose escalation. © RSNA, 2016 Online supplemental material is available for this article.
1965-07-21
S65-39907 (21 July 1965) --- Prime crew for the Gemini-Titan 5 (GT-5) spaceflight, astronauts Charles Conrad Jr. (in water) and L. Gordon Cooper Jr. (in raft) practice survival techniques following successful egress from their Gemini Static Article 5 spacecraft in the Gulf of Mexico. Cooper is command pilot and Conrad is pilot for the GT-5 mission.
Reference Equations for Static Lung Volumes and TLCO from a Population Sample in Northern Greece.
Michailopoulos, Pavlos; Kontakiotis, Theodoros; Spyratos, Dionisios; Argyropoulou-Pataka, Paraskevi; Sichletidis, Lazaros
2015-02-14
Background: The most commonly used reference equations for the measurement of static lung volumes/capacities and transfer factor of the lung for CO (TL CO ) are based on studies around 30-40 years old with significant limitations. Objectives: Our aim was to (1) develop reference equations for static lung volumes and TL CO using the current American Thoracic Society/European Respiratory Society guidelines, and (2) compare the equations derived with those most commonly used. Methods: Healthy Caucasian subjects (234 males and 233 females) aged 18-91 years were recruited. All of them were healthy never smokers with a normal chest X-ray. Static lung volumes and TL CO were measured with a single-breath technique according to the latest guidelines. Results: Curvilinear regression prediction equations derived from the present study were compared with those that are most commonly used. Our reference equations in accordance with the latest studies show lower values for all static lung volume parameters and TL CO as well as a different way of deviation of those parameters (i.e. declining with age total lung capacity, TL CO age decline in both sex and functional residual capacity age rise in males). Conclusions: We suggest that old reference values of static lung volumes and TL CO should be updated, and our perception of deviation of some spirometric parameters should be revised. Our new reference curvilinear equations derived according to the latest guidelines could contribute to the updating by respiratory societies of old existing reference values and result in a better estimation of the lung function of contemporary populations with similar Caucasian characteristics. © 2015 S. Karger AG, Basel.
Compliance of the respiratory system in newborn infants pre- and postsurfactant replacement therapy.
Kelly, E; Bryan, H; Possmayer, F; Frndova, H; Bryan, C
1993-04-01
Surfactant administration causes a rapid and dramatic improvement in gas exchange, but paradoxically, studies have failed to show an improvement in the mechanical properties of the lung. We have measured dynamic and static (passive flow-volume technique) compliance before and after a single dose of bovine lipid extract surfactant in 22 premature infants with RDS. This had no effect on the measured dynamic compliance. In contrast, surfactant significantly increased static compliance from 0.41 +/- 0.02 to 0.55 +/- 0.04 mL/cm H2O/kg. This improvement was the result of a substantial recruitment of lung volume after surfactant administration. This led us to reduce ventilator pressures, which produced an increase in both dynamic and static compliance, but did not recruit additional volume. We conclude that surfactant causes a substantial increase in static compliance due to volume recruitment, which is consistent with reports of increase in the measured FRC. However, despite this improvement, the compliance is still below our normal range.
Jonsson, Per; Lindmark, Lorentz; Axelsson, Jan; Karlsson, Lars; Lundberg, Lennart; Stegmayr, Bernd
2018-05-01
We were encouraged to investigate the reasons for large amounts of foam observed in bloodlines during hemodialysis (HD). Foam was visible in the venous air trap within the Artis Gambro dialysis device. Estimates of the extent of foam were graded (0-no foam, 10-extensive foam) by two persons that were blind to the type of dialyzer used. Thirty-seven patients were involved in the dialysis procedures. Consecutive dialyses were graded using dialyzers from Fresenius Medical Care (CorDiax dialyzers that were used for high flux HD-FX80 and FX100, and for hemodiafiltration-FX1000). The extracorporeal circuit was primed automatically by dialysate using Gambro Artis software 8.15 006 (Gambro, Dasco, Medolla Italy, Baxter, Chicago, IL, USA). The priming volume recommended by the manufacturer was 1100 mL, whereas our center uses 1500 mL. Extensive amounts of blood foam were visual in the air traps. Although the manufacturer recommended extension of priming volume up to 3000 mL, this did not eliminate the foam. Microbubble measurement during HD revealed the air to derive from the dialyzers. When changing to PF210H dialyzers (Baxter) and using a priming volume of 1500 mL, the foam was significantly less (P < 0.01). The extent of foam correlated with the size of the FX-dialyzer surface (P = 0.002). The auto-priming program was updated to version 8.21 by the manufacturer and the extent of foam in the air trap using FX dialyzers was now reduced and there was no longer a difference between FX and PF dialyzers, although less foam was still visible in the venous air trap during several dialyses. In conclusion, this study urgently calls attention to blood foam development in the venous air trap when using Artis devices and priming software 8.15 in combination with Fresenius dialyzers. Updated auto-priming software (version 8.21) of Artis should be requested to reduce the extent of foam for the Fresenius dialyzers. Other interactions may also be present. We recommend further studies to clarify these problems. Meanwhile caution is warranted for the combined use of dialysis devices and dialyzers with incompatible automatic priming. © 2018 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Arns, James A.
2016-08-01
The Subaru Prime Focus Spectrograph[1] (PFS) requires a suite of volume phase holographic (VPH) gratings that parse the observational spectrum into three sub-spectral regions. In addition, the red region has a second, higher resolution arm that includes a VPH grating that will eventually be incorporated into a grism. This paper describes the specifications of the four grating types, gives the theoretical performances of diffraction efficiency for the production designs and presents the measured performances on the gratings produced to date.
Abicht, Jan-Michael; Mayr, Tanja Axinja Jelena; Jauch, Judith; Guethoff, Sonja; Buchholz, Stefan; Reichart, Bruno; Bauer, Andreas
2018-01-01
Existing large-animal, ex vivo, cardiac perfusion models are restricted in their ability to establish an ischemia/reperfusion condition as seen in cardiac surgery or transplantation. Other working heart systems only challenge one ventricle or require a substantially larger priming volume. We describe a novel biventricular cardiac perfusion system with reduced priming volume. Juvenile pig hearts were cardiopleged, explanted, and reperfused ex vivo after 150 minutes of cold ischemia. Autologous whole blood was used as perfusate (minimal priming volume 350 mL). After 15 minutes of Langendorff perfusion (LM), the system was switched into a biventricular working mode (WM) and studied for 3 hours. During reperfusion, complete unloading of both ventricles and constant-pressure coronary perfusion was achieved. During working mode perfusion, the preload and afterload pressure of both ventricles was controlled within the targeted physiologic range. Functional parameters such as left ventricular work index were reduced in ex vivo working mode (in vivo: 787 ± 186 vs. 1 h WM 498 ± 66 mm Hg·mL/g·min; p < 0.01), but remained stable throughout the following study period (3 h WM 517 ± 103 mm Hg·mL/g·min; p = 0.63). Along with the elevated workload during WM, myocardial metabolism and oxygen consumption increased compared with LM (0.021 ± 0.08 vs. 0.06 ± 0.01 mL/min/g; 1 h after reperfusion). Histologic examination of the myocardium revealed no structural damage. In the ex vivo perfusion system, stable hemodynamic and metabolic conditions can be established for a period of 3 hours while functional and blood parameters are easily accessible. Moreover, because of the minimal priming volume, the novel ex vivo cardiac perfusion circuit allows for autologous perfusion, using the limited amount of blood available from the organ donating animal. Georg Thieme Verlag KG Stuttgart · New York.
Diastolic viscous properties of the intact canine left ventricle.
Nikolic, S D; Tamura, K; Tamura, T; Dahm, M; Frater, R W; Yellin, E L
1990-08-01
The viscoelastic model of the ventricle predicts that the rate of change of volume (strain rate) is a determinant of the instantaneous pressure in the ventricle during diastole. Because relaxation is not complete before the onset of filling, one cannot distinguish the individual effects of relaxation and viscosity unless the passive and active components that determine the ventricular pressure are separated. To overcome this problem, we used the method of ventricular volume clamping to compare the pressures in the fully relaxed ventricle at a given volume at zero strain rate (static pressure) and high strain rate (dynamic pressure). Six open-chest, fentanyl-anesthetized dogs were instrumented with micromanometers and an electronically controlled mitral valve occluder in series with the electromagnetic flow probe. We reasoned as follows: If there were significant viscosity, then the dynamic pressure would be higher than the static pressure. The static pressure was measured when the ventricle was completely relaxed following a mitral valve occlusion after an arbitrary filling volume had been achieved. The dynamic pressure was determined by delaying the onset of filling until relaxation was complete and then measuring the pressure at the same volume that was achieved when the static pressure was measured. In 19 different hemodynamic situations, the dynamic and static pressures were identical (mean difference, 0.1 +/- 0.8 mm Hg), indicating that in the passive ventricle viscoelastic effects are insignificant and do not contribute to the left ventricular diastolic pressure under normal filling rates.
Balderson, Michael; Brown, Derek; Johnson, Patricia; Kirkby, Charles
2016-01-01
The purpose of this work was to compare static gantry intensity-modulated radiation therapy (IMRT) with volume-modulated arc therapy (VMAT) in terms of tumor control probability (TCP) under scenarios involving large geometric misses, i.e., those beyond what are accounted for when margin expansion is determined. Using a planning approach typical for these treatments, a linear-quadratic-based model for TCP was used to compare mean TCP values for a population of patients who experiences a geometric miss (i.e., systematic and random shifts of the clinical target volume within the planning target dose distribution). A Monte Carlo approach was used to account for the different biological sensitivities of a population of patients. Interestingly, for errors consisting of coplanar systematic target volume offsets and three-dimensional random offsets, static gantry IMRT appears to offer an advantage over VMAT in that larger shift errors are tolerated for the same mean TCP. For example, under the conditions simulated, erroneous systematic shifts of 15mm directly between or directly into static gantry IMRT fields result in mean TCP values between 96% and 98%, whereas the same errors on VMAT plans result in mean TCP values between 45% and 74%. Random geometric shifts of the target volume were characterized using normal distributions in each Cartesian dimension. When the standard deviations were doubled from those values assumed in the derivation of the treatment margins, our model showed a 7% drop in mean TCP for the static gantry IMRT plans but a 20% drop in TCP for the VMAT plans. Although adding a margin for error to a clinical target volume is perhaps the best approach to account for expected geometric misses, this work suggests that static gantry IMRT may offer a treatment that is more tolerant to geometric miss errors than VMAT. Copyright © 2016 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
Evaluation of Geosynthetic-Reinforced Flexible Pavements using Static Plate Load Tests
DOT National Transportation Integrated Search
2010-01-01
This study focuses on the response of full-scale geogrid-reinforced flexible pavements to static surface loading. Specifically, static plate load (SPL) tests were performed on a low-volume, asphalt pavement frontage road in Eastern Arkansas, USA (the...
GORDON, RICHARD F., ASTRONAUT - TRAINING - GEMINI-TITAN (GT)-11 - WATER EGRESS - GULF
1966-07-23
S66-44497 (23 July 1966) --- Astronauts Charles Conrad Jr. (left) and Richard F. Gordon Jr. (right), prime crew for the Gemini-11 spaceflight, practice water egress procedures in the Gulf of Mexico. Static Article 5 was used in the training exercise. A MSC swimmer is in the water assisting in the training. Photo credit: NASA
Finite element modeling of ROPS in static testing and rear overturns.
Harris, J R; Mucino, V H; Etherton, J R; Snyder, K A; Means, K H
2000-08-01
Even with the technological advances of the last several decades, agricultural production remains one of the most hazardous occupations in the United States. Death due to tractor rollover is a prime contributor to this hazard. Standards for rollover protective structures (ROPS) performance and certification have been developed by groups such as the Society of Automotive Engineers (SAE) and the American Society of Agricultural Engineers (ASAE) to combat these problems. The current ROPS certification standard, SAE J2194, requires either a dynamic or static testing sequence or both. Although some ROPS manufacturers perform both the dynamic and static phases of SAE J2194 testing, it is possible for a ROPS to be certified for field operation using static testing alone. This research compared ROPS deformation response from a simulated SAE J2194 static loading sequence to ROPS deformation response as a result of a simulated rearward tractor rollover. Finite element analysis techniques for plastic deformation were used to simulate both the static and dynamic rear rollover scenarios. Stress results from the rear rollover model were compared to results from simulated static testing per SAE J2194. Maximum stress values from simulated rear rollovers exceeded maximum stress values recorded during simulated static testing for half of the elements comprising the uprights. In the worst case, the static model underpredicts dynamic model results by approximately 7%. In the best case, the static model overpredicts dynamic model results by approximately 32%. These results suggest the need for additional experimental work to characterize ROPS stress levels during staged overturns and during testing according to the SAE standard.
49 CFR 238.405 - Longitudinal static compressive strength.
Code of Federal Regulations, 2012 CFR
2012-10-01
... crash refuge for crewmembers occupying the cab of a power car, the underframe of the cab of a power car... volumes of a power car or a trailer car designed to crush as part of the crash energy management design...) The underframe of the occupied volume of each trailer car shall resist a minimum longitudinal static...
49 CFR 238.405 - Longitudinal static compressive strength.
Code of Federal Regulations, 2014 CFR
2014-10-01
... crash refuge for crewmembers occupying the cab of a power car, the underframe of the cab of a power car... volumes of a power car or a trailer car designed to crush as part of the crash energy management design...) The underframe of the occupied volume of each trailer car shall resist a minimum longitudinal static...
49 CFR 238.405 - Longitudinal static compressive strength.
Code of Federal Regulations, 2013 CFR
2013-10-01
... crash refuge for crewmembers occupying the cab of a power car, the underframe of the cab of a power car... volumes of a power car or a trailer car designed to crush as part of the crash energy management design...) The underframe of the occupied volume of each trailer car shall resist a minimum longitudinal static...
Studier, F. William
1995-04-18
Random and directed priming methods for determining nucleotide sequences by enzymatic sequencing techniques, using libraries of primers of lengths 8, 9 or 10 bases, are disclosed. These methods permit direct sequencing of nucleic acids as large as 45,000 base pairs or larger without the necessity for subcloning. Individual primers are used repeatedly to prime sequence reactions in many different nucleic acid molecules. Libraries containing as few as 10,000 octamers, 14,200 nonamers, or 44,000 decamers would have the capacity to determine the sequence of almost any cosmid DNA. Random priming with a fixed set of primers from a smaller library can also be used to initiate the sequencing of individual nucleic acid molecules, with the sequence being completed by directed priming with primers from the library. In contrast to random cloning techniques, a combined random and directed priming strategy is far more efficient.
Studier, F.W.
1995-04-18
Random and directed priming methods for determining nucleotide sequences by enzymatic sequencing techniques, using libraries of primers of lengths 8, 9 or 10 bases, are disclosed. These methods permit direct sequencing of nucleic acids as large as 45,000 base pairs or larger without the necessity for subcloning. Individual primers are used repeatedly to prime sequence reactions in many different nucleic acid molecules. Libraries containing as few as 10,000 octamers, 14,200 nonamers, or 44,000 decamers would have the capacity to determine the sequence of almost any cosmid DNA. Random priming with a fixed set of primers from a smaller library can also be used to initiate the sequencing of individual nucleic acid molecules, with the sequence being completed by directed priming with primers from the library. In contrast to random cloning techniques, a combined random and directed priming strategy is far more efficient. 2 figs.
Gamma Prime Precipitation, Dislocation Densities, and TiN in Creep-Exposed Inconel 617 Alloy
NASA Astrophysics Data System (ADS)
Krishna, Ram; Atkinson, Helen V.; Hainsworth, Sarah V.; Gill, Simon P.
2016-01-01
Inconel 617 is a solid-solution-strengthened Ni-based superalloy with a small amount of gamma prime (γ') present. Here, samples are examined in the as-received condition and after creep exposure at 923 K (650 °C) for 574 hours and 45,000 hours and at 973 K (700 °C) for 4000 hours. The stress levels are intermediate (estimated, respectively, as of the order of 350, 275, and 200 MPa) and at levels of interest for the future operation of power plant. The hardness of the specimens has been measured in the gage length and the head. TEM thin foils have been obtained to quantify dislocation densities (3.5 × 1013 for the as-received, 5.0 × 1014, 5.9 × 1014, and 3.5 × 1014 lines/m2 for the creep-exposed specimens, respectively). There are no previous data in the literature for dislocation densities in this alloy after creep exposure. There is some evidence from the dislocation densities that for the creep-exposed samples, the higher hardness in the gage length in comparison with the creep test specimen head is due to work hardening rather than any other effect. Carbon replicas have been used to extract gamma prime precipitates. The morphology of γ' precipitates in the `as-received' condition was spheroidal with an average diameter of 18 nm. The morphology of these particles does not change with creep exposure but the size increases to 30 nm after 574 hours at 923 K (650 °C) but with little coarsening in 45,000 hours. At 973 K (700 °C) 4000 hours, the average gamma prime size is 32 nm. In the TEM images of the replicas, the particles overlap, and therefore, a methodology has been developed to estimate the volume fraction of gamma prime in the alloy given the carbon replica film thickness. The results are 5.8 vol pct in the as-received and then 2.9, 3.2, and 3.4 vol pct, respectively, for the creep-exposed specimens. The results are compared with predictions from thermodynamic analysis given the alloy compositions. Thermodynamic prediction shows that nitrogen content is important in determining the gamma prime volume fraction. This has not previously been identified in the literature. The higher the nitrogen content, the lower the gamma prime volume fraction. This may explain inconsistencies between previous experimental estimates of gamma prime volume fraction in the literature and the results here. The observed decrease in the γ' volume fraction with creep exposure would correspond to an increase in TiN. At present, there are insufficient experimental data to prove that this predicted relationship occurs in practice. However, it is observed that there is a higher volume fraction of TiN precipitates in the gage length of a creep sample than in the head. This suggests that secondary TiN particles are precipitating at the expense of existing γ' due to the ingress of N from the atmosphere, possibly via creep cracks penetrating in from the surface of the gage length. This effect is not expected to be observed in real components which are much larger and operate in different atmospheres. However, this highlights the need to be conscious of this possibility when carrying out creep testing.
Does culture influence what and how we think? Effects of priming individualism and collectivism.
Oyserman, Daphna; Lee, Spike W S
2008-03-01
Do differences in individualism and collectivism influence values, self-concept content, relational assumptions, and cognitive style? On the one hand, the cross-national literature provides an impressively consistent picture of the predicted systematic differences; on the other hand, the nature of the evidence is inconclusive. Cross-national evidence is insufficient to argue for a causal process, and comparative data cannot specify if effects are due to both individualism and collectivism, only individualism, only collectivism, or other factors (including other aspects of culture). To address these issues, the authors conducted a meta-analysis of the individualism and collectivism priming literature, with follow-up moderator analyses. Effect sizes were moderate for relationality and cognition, small for self-concept and values, robust across priming methods and dependent variables, and consistent in direction and size with cross-national effects. Results lend support to a situated model of culture in which cross-national differences are not static but dynamically consistent due to the chronic and moment-to-moment salience of individualism and collectivism. Examination of the unique effects of individualism and collectivism versus other cultural factors (e.g., honor, power) awaits the availability of research that primes these factors. (c) 2008 APA, all rights reserved.
Grasping the pain: motor resonance with dangerous affordances.
Anelli, Filomena; Borghi, Anna M; Nicoletti, Roberto
2012-12-01
Two experiments, one on school-aged children and one on adults, explored the mechanisms underlying responses to an image prime (hand vs. control object) followed by graspable objects that were, in certain cases, dangerous. Participants were presented with different primes (a male, a female and a robotic grasping-hand; a male and a female static-hand; a control stimulus) and objects representing two risk levels (neutral and dangerous). The task required that a natural/artifact categorization task be performed by pressing different keys. In both adults and children graspable objects activated a facilitating motor response, while dangerous objects evoked aversive affordances, generating an interference-effect. Both children and adults were sensitive to the distinction between biological and non-biological hands, however detailed resonant mechanisms related to the hand-prime gender emerged only in adults. Implications for how the concept of "dangerous object" develops and the relationship between resonant mechanisms and perception of danger are discussed. Copyright © 2012 Elsevier Inc. All rights reserved.
1981-09-01
and constrain the output of major energy- consuming sectors. Government stockpiles are most effectively used in a " pump -priming" role. They have to...11 - stockpile for " pump priming" are fuels and basic metals such as iron, steel, copper, and aluminum. The esoteric metals are of secondary...are released, the more impact they have in aiding recovery. Particularly if resource imports are interrupted, post-attack " pump priming" is the best
Real-time 3-D ultrafast ultrasound quasi-static elastography in vivo
Papadacci, Clement; Bunting, Ethan A.; Konofagou, Elisa E.
2017-01-01
Ultrasound elastography, a technique used to assess mechanical properties of soft tissue is of major interest in the detection of breast cancer as it is stiffer than the surroundings. Techniques such as ultrasound quasi-static elastography have been developed to assess the strain distribution in soft tissues in two dimensions using a quasi-static compression. However, tumors can exhibit very heterogeneous shape, a three dimensions approach would be then necessary to measure accurately the tumor volume and remove operator dependency. To ensure this issue, several 3-D quasi-static elastographic approaches have been proposed. However, all these approaches suffered from a long acquisition time to acquire 3-D volumes resulting in the impossibility to perform real-time and the creation of artifacts. The long acquisition time comes from both the use of focused ultrasound emissions and the fact that the volume was made from a stack of two dimensions images acquired by mechanically translating an ultrasonic array. Being able to acquire volume at high volume rates is thus crucial to perform real-time with a simple freehand compression and to avoid signal decorrelation coming from hand motions or natural motions such as the respiratory. In this study we developed for the first time, the 3-D ultrafast ultrasound quasi-static elastography method to estimate 3-D axial strain distribution in vivo in real-time. Acquisitions were performed with a 2-D matrix array probe of 256 elements (16-by-16 elements). 100 plane waves were emitted at a volume rate of 100 volumes/sec during a continuous motorized compression. 3-D B-mode volumes and 3-D B-mode cumulative axial strain volumes were estimated on a two-layers gelatin phantom with different stiffness, in a stiff inclusion embedded in a soft gelatin phantoms, in a soft inclusion embedded in a stiff gelatin phantom and in an ex vivo canine liver before and after a high focused ultrasound (HIFU) ablation. In each case, we were able to image in real-time and in entire volumes the axial strain distribution and were able to detect the differences between stiff and soft structures with a good sensitivity. In addition, we were able to detect the stiff lesion in the ex vivo canine liver after HIFU ablation. Finally, we demonstrated the in vivo feasibility of the method using freehand compression on the calf of a human volunteer and were able to retrieve 3-D axial strain volume in real-time depicting the differences in stiffness of the two muscles which compose the calf. The 3-D ultrafast ultrasound quasi-static elastography method could have a major clinical impact for the real-time detection in three dimensions of breast cancer in patients using a simple freehand scanning. PMID:27483021
Göttler, Jens; Lukas, Mathias; Kluge, Anne; Kaczmarz, Stephan; Gempt, Jens; Ringel, Florian; Mustafa, Mona; Meyer, Bernhard; Zimmer, Claus; Schwaiger, Markus; Förster, Stefan; Preibisch, Christine; Pyka, Thomas
2017-03-01
18 F-fluorethyltyrosine-(FET)-PET and MRI-based relative cerebral blood volume (rCBV) have both been used to characterize gliomas. Recently, inter-individual correlations between peak static FET-uptake and rCBV have been reported. Herein, we assess the local intra-lesional relation between FET-PET parameters and rCBV. Thirty untreated glioma patients (27 high-grade) underwent simultaneous PET/MRI on a 3 T hybrid scanner obtaining structural and dynamic susceptibility contrast sequences. Static FET-uptake and dynamic FET-slope were correlated with rCBV within tumour hotspots across patients and intra-lesionally using a mixed-effects model to account for inter-individual variation. Furthermore, maximal congruency of tumour volumes defined by FET-uptake and rCBV was determined. While the inter-individual relationship between peak static FET-uptake and rCBV could be confirmed, our intra-lesional, voxel-wise analysis revealed significant positive correlations (median r = 0.374, p < 0.0001). Similarly, significant inter- and intra-individual correlations were observed between FET-slope and rCBV. However, rCBV explained only 12% of the static and 5% of the dynamic FET-PET variance and maximal overlap of respective tumour volumes was 37% on average. Our results show that the relation between peak values of MR-based rCBV and static FET-uptake can also be observed intra-individually on a voxel basis and also applies to a dynamic FET parameter, possibly determining hotspots of higher biological malignancy. However, just a small part of the FET-PET signal variance is explained by rCBV and tumour volumes determined by the two modalities showed only moderate overlap. These findings indicate that FET-PET and MR-based rCBV provide both congruent and complimentary information on glioma biology.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Balderson, Michael, E-mail: michael.balderson@rmp.uhn.ca; Brown, Derek; Johnson, Patricia
The purpose of this work was to compare static gantry intensity-modulated radiation therapy (IMRT) with volume-modulated arc therapy (VMAT) in terms of tumor control probability (TCP) under scenarios involving large geometric misses, i.e., those beyond what are accounted for when margin expansion is determined. Using a planning approach typical for these treatments, a linear-quadratic–based model for TCP was used to compare mean TCP values for a population of patients who experiences a geometric miss (i.e., systematic and random shifts of the clinical target volume within the planning target dose distribution). A Monte Carlo approach was used to account for themore » different biological sensitivities of a population of patients. Interestingly, for errors consisting of coplanar systematic target volume offsets and three-dimensional random offsets, static gantry IMRT appears to offer an advantage over VMAT in that larger shift errors are tolerated for the same mean TCP. For example, under the conditions simulated, erroneous systematic shifts of 15 mm directly between or directly into static gantry IMRT fields result in mean TCP values between 96% and 98%, whereas the same errors on VMAT plans result in mean TCP values between 45% and 74%. Random geometric shifts of the target volume were characterized using normal distributions in each Cartesian dimension. When the standard deviations were doubled from those values assumed in the derivation of the treatment margins, our model showed a 7% drop in mean TCP for the static gantry IMRT plans but a 20% drop in TCP for the VMAT plans. Although adding a margin for error to a clinical target volume is perhaps the best approach to account for expected geometric misses, this work suggests that static gantry IMRT may offer a treatment that is more tolerant to geometric miss errors than VMAT.« less
NASA Astrophysics Data System (ADS)
Trottier, H. D.; Shakespeare, N. H.; Lepage, G. P.; MacKenzie, P. B.
2002-05-01
Perturbative coefficients for Wilson loops and the static-quark self-energy are extracted from Monte Carlo simulations at weak coupling. The lattice volumes and couplings are chosen to ensure that the lattice momenta are all perturbative. Twisted boundary conditions are used to eliminate the effects of lattice zero modes and to suppress nonperturbative finite-volume effects due to Z(3) phases. Simulations of the Wilson gluon action are done with both periodic and twisted boundary conditions, and over a wide range of lattice volumes (from 34 to 164) and couplings (from β~9 to β~60). A high precision comparison is made between the simulation data and results from finite-volume lattice perturbation theory. The Monte Carlo results are shown to be in excellent agreement with perturbation theory through second order. New results for third-order coefficients for a number of Wilson loops and the static-quark self-energy are reported.
40 CFR 60.393 - Performance test and compliance provisions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... per volume of applied coating solids (G) during each calendar month for each affected facility by the following equation: EC16NO91.030 (E) For each EDP prime coat operation, calculate the turnover ratio (RT) by....392(a). (ii) If the volume weighted average mass of VOC per volume of applied coating solids (G...
Bokov, P; Delclaux, C
2016-02-01
Resting pulmonary function tests (PFT) include the assessment of ventilatory capacity: spirometry (forced expiratory flows and mobilisable volumes) and static volume assessment, notably using body plethysmography. Spirometry allows the potential definition of obstructive defect, while static volume assessment allows the potential definition of restrictive defect (decrease in total lung capacity) and thoracic hyperinflation (increase in static volumes). It must be kept in mind that this evaluation is incomplete and that an assessment of ventilatory demand is often warranted, especially when facing dyspnoea: evaluation of arterial blood gas (searching for respiratory insufficiency) and measurement of the transfer coefficient of the lung, allowing with the measurement of alveolar volume to calculate the diffusing capacity of the lung for CO (DLCO: assessment of alveolar-capillary wall and capillary blood volume). All these pulmonary function tests have been the subject of an Americano-European Task force (standardisation of lung function testing) published in 2005, and translated in French in 2007. Interpretative strategies for lung function tests have been recommended, which define abnormal lung function tests using the 5th and 95th percentiles of predicted values (lower and upper limits of normal values). Thus, these recommendations need to be implemented in all pulmonary function test units. A methacholine challenge test will only be performed in the presence of an intermediate pre-test probability for asthma (diagnostic uncertainty), which is an infrequent setting. The most convenient exertional test is the 6-minute walk test that allows the assessment of walking performance, the search for arterial desaturation and the quantification of dyspnoea complaint. Copyright © 2015 Société nationale française de médecine interne (SNFMI). Published by Elsevier SAS. All rights reserved.
Xu, Z N
2014-12-01
In this study, an error analysis is performed to study real water drop images and the corresponding numerically generated water drop profiles for three widely used static contact angle algorithms: the circle- and ellipse-fitting algorithms and the axisymmetric drop shape analysis-profile (ADSA-P) algorithm. The results demonstrate the accuracy of the numerically generated drop profiles based on the Laplace equation. A significant number of water drop profiles with different volumes, contact angles, and noise levels are generated, and the influences of the three factors on the accuracies of the three algorithms are systematically investigated. The results reveal that the above-mentioned three algorithms are complementary. In fact, the circle- and ellipse-fitting algorithms show low errors and are highly resistant to noise for water drops with small/medium volumes and contact angles, while for water drop with large volumes and contact angles just the ADSA-P algorithm can meet accuracy requirement. However, this algorithm introduces significant errors in the case of small volumes and contact angles because of its high sensitivity to noise. The critical water drop volumes of the circle- and ellipse-fitting algorithms corresponding to a certain contact angle error are obtained through a significant amount of computation. To improve the precision of the static contact angle measurement, a more accurate algorithm based on a combination of the three algorithms is proposed. Following a systematic investigation, the algorithm selection rule is described in detail, while maintaining the advantages of the three algorithms and overcoming their deficiencies. In general, static contact angles over the entire hydrophobicity range can be accurately evaluated using the proposed algorithm. The ease of erroneous judgment in static contact angle measurements is avoided. The proposed algorithm is validated by a static contact angle evaluation of real and numerically generated water drop images with different hydrophobicity values and volumes.
Tables of stark level transition probabilities and branching ratios in hydrogen-like atoms
NASA Technical Reports Server (NTRS)
Omidvar, K.
1980-01-01
The transition probabilities which are given in terms of n prime k prime and n k are tabulated. No additional summing or averaging is necessary. The electric quantum number k plays the role of the angular momentum quantum number l in the presence of an electric field. The branching ratios between stark levels are also tabulated. Necessary formulas for the transition probabilities and branching ratios are given. Symmetries are discussed and selection rules are given. Some disagreements for some branching ratios are found between the present calculation and the measurement of Mark and Wierl. The transition probability multiplied by the statistical weight of the initial state is called the static intensity J sub S, while the branching ratios are called the dynamic intensity J sub D.
Double-hit mouse model of cigarette smoke priming for acute lung injury.
Sakhatskyy, Pavlo; Wang, Zhengke; Borgas, Diana; Lomas-Neira, Joanne; Chen, Yaping; Ayala, Alfred; Rounds, Sharon; Lu, Qing
2017-01-01
Epidemiological studies indicate that cigarette smoking (CS) increases the risk and severity of acute lung injury (ALI)/acute respiratory distress syndrome (ARDS). The mechanism is not understood, at least in part because of lack of animal models that reproduce the key features of the CS priming process. In this study, using two strains of mice, we characterized a double-hit mouse model of ALI induced by CS priming of injury caused by lipopolysaccharide (LPS). C57BL/6 and AKR mice were preexposed to CS briefly (3 h) or subacutely (3 wk) before intratracheal instillation of LPS and ALI was assessed 18 h after LPS administration by measuring lung static compliance, lung edema, vascular permeability, inflammation, and alveolar apoptosis. We found that as little as 3 h of exposure to CS enhanced LPS-induced ALI in both strains of mice. Similar exacerbating effects were observed after 3 wk of preexposure to CS. However, there was a strain difference in susceptibility to CS priming for ALI, with a greater effect in AKR mice. The key features we observed suggest that 3 wk of CS preexposure of AKR mice is a reproducible, clinically relevant animal model that is useful for studying mechanisms and treatment of CS priming for a second-hit-induced ALI. Our data also support the concept that increased susceptibility to ALI/ARDS is an important adverse health consequence of CS exposure that needs to be taken into consideration when treating critically ill individuals.
Double-hit mouse model of cigarette smoke priming for acute lung injury
Sakhatskyy, Pavlo; Wang, Zhengke; Borgas, Diana; Lomas-Neira, Joanne; Chen, Yaping; Ayala, Alfred; Rounds, Sharon
2016-01-01
Epidemiological studies indicate that cigarette smoking (CS) increases the risk and severity of acute lung injury (ALI)/acute respiratory distress syndrome (ARDS). The mechanism is not understood, at least in part because of lack of animal models that reproduce the key features of the CS priming process. In this study, using two strains of mice, we characterized a double-hit mouse model of ALI induced by CS priming of injury caused by lipopolysaccharide (LPS). C57BL/6 and AKR mice were preexposed to CS briefly (3 h) or subacutely (3 wk) before intratracheal instillation of LPS and ALI was assessed 18 h after LPS administration by measuring lung static compliance, lung edema, vascular permeability, inflammation, and alveolar apoptosis. We found that as little as 3 h of exposure to CS enhanced LPS-induced ALI in both strains of mice. Similar exacerbating effects were observed after 3 wk of preexposure to CS. However, there was a strain difference in susceptibility to CS priming for ALI, with a greater effect in AKR mice. The key features we observed suggest that 3 wk of CS preexposure of AKR mice is a reproducible, clinically relevant animal model that is useful for studying mechanisms and treatment of CS priming for a second-hit-induced ALI. Our data also support the concept that increased susceptibility to ALI/ARDS is an important adverse health consequence of CS exposure that needs to be taken into consideration when treating critically ill individuals. PMID:27864287
Moussa, Mira; Carrel, Jean-Pierre; Scherrer, Susanne; Cattani-Lorente, Maria; Wiskott, Anselm; Durual, Stéphane
2015-01-01
Introduction: A 3D-printed construct made of orthogonally layered strands of tricalcium phosphate (TCP) and hydroxyapatite has recently become available. The material provides excellent osteoconductivity. We simulated a medium-term experiment in a sheep calvarial model by priming the blocks with BMP-2. Vertical bone growth/maturation and material resorption were evaluated. Materials and methods: Titanium hemispherical caps were filled with either bare- or BMP-2 primed constructs and placed onto the calvaria of adult sheep (n = 8). Histomorphometry was performed after 8 and 16 weeks. Results: After 8 weeks, relative to bare constructs, BMP-2 stimulation led to a two-fold increase in bone volume (Bare: 22% ± 2.1%; BMP-2 primed: 50% ± 3%) and a 3-fold decrease in substitute volume (Bare: 47% ± 5%; BMP-2 primed: 18% ± 2%). These rates were still observed at 16 weeks. The new bone grew and matured to a haversian-like structure while the substitute material resorbed via cell- and chemical-mediation. Conclusion: By priming the 3D construct with BMP-2, bone metabolism was physiologically accelerated, that is, enhancing vertical bone growth and maturation as well as material bioresorption. The scaffolding function of the block was maintained, leaving time for the bone to grow and mature to a haversian-like structure. In parallel, the material resorbed via cell-mediated and chemical processes. These promising results must be confirmed in clinical tests.
A comparison of dynamic and static economic models of uneven-aged stand management
Robert G. Haight
1985-01-01
Numerical techniques have been used to compute the discrete-time sequence of residual diameter distributions that maximize the present net worth (PNW) of harvestable volume from an uneven-aged stand. Results contradicted optimal steady-state diameter distributions determined with static analysis. In this paper, optimality conditions for solutions to dynamic and static...
Camiciottoli, G; Diciotti, S; Bartolucci, M; Orlandi, I; Bigazzi, F; Matucci-Cerinic, M; Pistolesi, M; Mascalchi, M
2013-03-01
Spiral low-dose computed tomography (LDCT) permits to measure whole-lung volume and density in a single breath-hold. To evaluate the agreement between static lung volumes measured with LDCT and pulmonary function test (PFT) and the correlation between the LDCT volumes and lung density in restrictive lung disease. Patients with Systemic Sclerosis (SSc) with (n = 24) and without (n = 16) pulmonary involvement on sequential thin-section CT and patients with chronic obstructive pulmonary disease (COPD)(n = 29) underwent spirometrically-gated LDCT at 90% and 10% of vital capacity to measure inspiratory and expiratory lung volumes and mean lung attenuation (MLA). Total lung capacity and residual volume were measured the same day of CT. Inspiratory [95% limits of agreement (95% LoA)--43.8% and 39.2%] and expiratory (95% LoA -45.8% and 37.1%) lung volumes measured on LDCT and PFT showed poor agreement in SSc patients with pulmonary involvement, whereas they were in substantial agreement (inspiratory 95% LoA -14.1% and 16.1%; expiratory 95% LoA -13.5% and 23%) in SSc patients without pulmonary involvement and in inspiratory scans only (95% LoA -23.1% and 20.9%) of COPD patients. Inspiratory and expiratory LDCT volumes, MLA and their deltas differentiated both SSc patients with or without pulmonary involvement from COPD patients. LDCT lung volumes and density were not correlated in SSc patients with pulmonary involvement, whereas they did correlate in SSc without pulmonary involvement and in COPD patients. In restrictive lung disease due to SSc there is poor agreement between static lung volumes measured using LDCT and PFT and the relationship between volume and density values on CT is altered.
Microstructural Characterization and Modeling of SLM Superalloy 718
NASA Technical Reports Server (NTRS)
Smith, Tim M.; Sudbrack, Chantal K.; Bonacuse, Pete; Rogers, Richard
2017-01-01
Superalloy 718 is an excellent candidate for selective laser melting (SLM) fabrication due to a combination of excellent mechanical properties and workability. Predicting and validating the microstructure of SLM-fabricated Superalloy 718 after potential post heat-treatment paths is an important step towards producing components comparable to those made using conventional methods. At present, obtaining accurate volume fraction and size measurements of gamma-double-prime, gamma-prime and delta precipitates has been challenging due to their size, low volume fractions, and similar chemistries. A technique combining high resolution distortion corrected SEM imaging and with x-ray energy dispersive spectroscopy has been developed to accurately and independently measure the size and volume fractions of the three precipitates. These results were further validated using x-ray diffraction and phase extraction methods and compared to the precipitation kinetics predicted by PANDAT and JMatPro. Discrepancies are discussed in context of materials properties, model assumptions, sampling, and experimental errors.
Astronaut John W. Young during water egress training
1966-06-18
S66-39691 (18 June 1966) --- Astronaut John W. Young, prime crew command pilot for the Gemini-10 spaceflight, sits in Static Article 5 during water egress training activity onboard the NASA Motor Vessel Retriever. The SA-5 will be placed in the water and he and astronaut Michael Collins will then practice egress and water survival techniques. At right is Gordon Harvey, Spacecraft Operations Branch, Flight Crew Support Division. Photo credit: NASA
Fluid Transient Analysis during Priming of Evacuated Line
NASA Technical Reports Server (NTRS)
Bandyopadhyay, Alak; Majumdar, Alok K.; Holt, Kimberley
2017-01-01
Water hammer analysis in pipe lines, in particularly during priming into evacuated lines is important for the design of spacecraft and other in-space application. In the current study, a finite volume network flow analysis code is used for modeling three different geometrical configurations: the first two being straight pipe, one with atmospheric air and other with evacuated line, and the third case is a representation of a complex flow network system. The numerical results show very good agreement qualitatively and quantitatively with measured data available in the literature. The peak pressure and impact time in case of straight pipe priming in evacuated line shows excellent agreement.
Gelen, Ertugrul; Dede, Muhittin; Bingul, Bergun Meric; Bulgan, Cigdem; Aydin, Mensure
2012-01-01
The purpose of this study was to compare the acute effects of static stretching; dynamic exercises and high volume upper extremity plyometric activity on tennis serve performance. Twenty-six elite young tennis players (15.1 ± 4.2 years, 167.9 ± 5.8 cm and 61.6 ± 8.1 kg) performed 4 different warm-up (WU) routines in a random order on non-consecutive days. The WU methods consisted of traditional WU (jogging, rally and serve practice) (TRAD); traditional WU and static stretching (TRSS); traditional WU and dynamic exercise (TRDE); and traditional WU and high volume upper extremity plyometric activity (TRPLYP). Following each WU session, subjects were tested on a tennis serve ball speed test. TRAD, TRSS, TRDE and TRPLYO were compared by repeated measurement analyses of variance and post-hoc comparisons. In this study a 1 to 3 percent increase in tennis serve ball speed was recorded in TRDE and TRPLYO when compared to TRAD (p< 0.05). However, no significant change in ball speed performance between TRSS and TRAD. (p> 0.05). ICCs for ball speed showed strong reliability (0.82 to 0.93) for the ball speed measurements.The results of this study indicate that dynamic and high volume upper extremity plyometric WU activities are likely beneficial to serve speed of elite junior tennis players. Key points After the traditional warm up in tennis, static stretching has no effect on serve speed. Tennis players should perform dynamic exercises and/or high volume upper extremity plyometric activities to improve their athletic performance. PMID:24150068
Static harmonization of dynamically harmonized Fourier transform ion cyclotron resonance cell.
Zhdanova, Ekaterina; Kostyukevich, Yury; Nikolaev, Eugene
2017-08-01
Static harmonization in the Fourier transform ion cyclotron resonance cell improves the resolving power of the cell and prevents dephasing of the ion cloud in the case of any trajectory of the charged particle, not necessarily axisymmetric cyclotron (as opposed to dynamic harmonization). We reveal that the Fourier transform ion cyclotron resonance cell with dynamic harmonization (paracell) is proved to be statically harmonized. The volume of the statically harmonized potential distribution increases with an increase in the number of trap segments.
Ehinger, David; Weise, Jörg; Baumeister, Joachim; Funk, Alexander; Waske, Anja; Krüger, Lutz; Martin, Ulrich
2018-04-24
The implementation of hollow S60HS glass microspheres and Fillite 106 cenospheres in a martensitically transformable AISI 304L stainless steel matrix was realized by means of metal injection molding of feedstock with varying fractions of the filler material. The so-called TRIP-steel syntactic foams were studied with respect to their behavior under quasi-static compression and dynamic impact loading. The interplay between matrix material behavior and foam structure was discussed in relation to the findings of micro-structural investigations, electron back scatter diffraction EBSD phase analyses and magnetic measurements. During processing, the cenospheres remained relatively stable retaining their shape while the glass microspheres underwent disintegration associated with the formation of pre-cracked irregular inclusions. Consequently, the AISI 304L/Fillite 106 syntactic foams exhibited a higher compression stress level and energy absorption capability as compared to the S60HS-containing variants. The α ′ -martensite kinetic of the steel matrix was significantly influenced by material composition, strain rate and arising deformation temperature. The highest ferromagnetic α ′ -martensite phase fraction was detected for the AISI 304L/S60HS batches and the lowest for the TRIP-steel bulk material. Quasi-adiabatic sample heating, a gradual decrease in strain rate and an enhanced degree of damage controlled the mechanical deformation response of the studied syntactic foams under dynamic impact loading.
NASA Astrophysics Data System (ADS)
Gao, Siwen; Rajendran, Mohan Kumar; Fivel, Marc; Ma, Anxin; Shchyglo, Oleg; Hartmaier, Alexander; Steinbach, Ingo
2015-10-01
Three-dimensional discrete dislocation dynamics (DDD) simulations in combination with the phase-field method are performed to investigate the influence of different realistic Ni-base single crystal superalloy microstructures with the same volume fraction of {γ\\prime} precipitates on plastic deformation at room temperature. The phase-field method is used to generate realistic microstructures as the boundary conditions for DDD simulations in which a constant high uniaxial tensile load is applied along different crystallographic directions. In addition, the lattice mismatch between the γ and {γ\\prime} phases is taken into account as a source of internal stresses. Due to the high antiphase boundary energy and the rare formation of superdislocations, precipitate cutting is not observed in the present simulations. Therefore, the plastic deformation is mainly caused by dislocation motion in γ matrix channels. From a comparison of the macroscopic mechanical response and the dislocation evolution for different microstructures in each loading direction, we found that, for a given {γ\\prime} phase volume fraction, the optimal microstructure should possess narrow and homogeneous γ matrix channels.
NASA Technical Reports Server (NTRS)
Mackay, R. A.
1984-01-01
Changes in the morphology of the gamma prime precipitate were examined during tensile creep at temperatures between 927 and 1038 C in 001-oriented single crystals of a Ni-Al-Mo-Ta superalloy. In this alloy, which has a large negative misfit of -0.80%, the gamma prime particles link together during creep to form platelets, or rafts, which are aligned with their broad faces perpendicular to the applied tensile axis. The dimensions of the gamma and gamma prime phases were measured as directional coarsening developed in an attempt to trace the changing morphology under various stress levels. In addition, the effects of initial microstructure, as well as slight compositional variations, were related to raft development and creep properties. The results showed that directional coarsening of gamma prime began during primary creep, and under certain conditions, continued to develop after the onset of steady-state creep. The length of the rafts increased linearly with time up to a plateau region. The thickness of the rafts, however, remained equal to the initial gamma prime size at least up through the onset of tertiary creep; this is a clear indication of the stability of the finely-spaced gamma-gamma prime lamellar structure. It was found that the single crystals with the finest gamma prime size exhibited the longest creep lives, because the resultant rafted structure had a larger number of gamma-gamma prime interfaces per unit volume of material.
Kelher, Marguerite R.; Khan, Samina Y.; LaSarre, Monica; West, F. Bernadette; Land, Kevin J.; Mish, Barbara; Ceriano, Linda; Sowemimo-Coker, Samuel
2014-01-01
Transfusion-related acute lung injury (TRALI) remains a significant cause of transfusion-related mortality with red cell transfusion. We hypothesize that prestorage filtration may reduce proinflammatory activity in the red blood cell (RBC) supernatant and prevent TRALI. Filters were manufactured for both small volumes and RBC units. Plasma containing antibodies to human lymphocyte antigen (HLA)-A2 or human neutrophil antigen (HNA)-3a was filtered, and immunoglobulins and specific HNA-3a and HLA-2a neutrophil (PMN) priming activity were measured. Antibodies to OX27 were added to plasma, and filtration was evaluated in a 2-event animal model of TRALI. RBC units from 31 donors known to have antibodies against HLA antigens and from 16 antibody-negative controls were filtered. Furthermore, 4 RBC units were drawn and underwent standard leukoreduction. Immunoglobulins, HLA antibodies, PMN priming activity, and the ability to induce TRALI in an animal model were measured. Small-volume filtration of plasma removed >96% of IgG, antibodies to HLA-A2 and HNA-3a, and their respective priming activity, as well as mitigating antibody-mediated in vivo TRALI. In RBC units, experimental filtration removed antibodies to HLA antigens and inhibited the accumulation of lipid priming activity and lipid-mediated TRALI. We conclude that filtration removes proinflammatory activity and the ability to induce TRALI from RBCs and may represent a TRALI mitigation step. PMID:24747436
Knotting probability of self-avoiding polygons under a topological constraint.
Uehara, Erica; Deguchi, Tetsuo
2017-09-07
We define the knotting probability of a knot K by the probability for a random polygon or self-avoiding polygon (SAP) of N segments having the knot type K. We show fundamental and generic properties of the knotting probability particularly its dependence on the excluded volume. We investigate them for the SAP consisting of hard cylindrical segments of unit length and radius r ex . For various prime and composite knots, we numerically show that a compact formula describes the knotting probabilities for the cylindrical SAP as a function of segment number N and radius r ex . It connects the small-N to the large-N behavior and even to lattice knots in the case of large values of radius. As the excluded volume increases, the maximum of the knotting probability decreases for prime knots except for the trefoil knot. If it is large, the trefoil knot and its descendants are dominant among the nontrivial knots in the SAP. From the factorization property of the knotting probability, we derive a sum rule among the estimates of a fitting parameter for all prime knots, which suggests the local knot picture and the dominance of the trefoil knot in the case of large excluded volumes. Here we remark that the cylindrical SAP gives a model of circular DNA which is negatively charged and semiflexible, where radius r ex corresponds to the screening length.
Knotting probability of self-avoiding polygons under a topological constraint
NASA Astrophysics Data System (ADS)
Uehara, Erica; Deguchi, Tetsuo
2017-09-01
We define the knotting probability of a knot K by the probability for a random polygon or self-avoiding polygon (SAP) of N segments having the knot type K. We show fundamental and generic properties of the knotting probability particularly its dependence on the excluded volume. We investigate them for the SAP consisting of hard cylindrical segments of unit length and radius rex. For various prime and composite knots, we numerically show that a compact formula describes the knotting probabilities for the cylindrical SAP as a function of segment number N and radius rex. It connects the small-N to the large-N behavior and even to lattice knots in the case of large values of radius. As the excluded volume increases, the maximum of the knotting probability decreases for prime knots except for the trefoil knot. If it is large, the trefoil knot and its descendants are dominant among the nontrivial knots in the SAP. From the factorization property of the knotting probability, we derive a sum rule among the estimates of a fitting parameter for all prime knots, which suggests the local knot picture and the dominance of the trefoil knot in the case of large excluded volumes. Here we remark that the cylindrical SAP gives a model of circular DNA which is negatively charged and semiflexible, where radius rex corresponds to the screening length.
IMP 8. Volume 1: EM field experiment
NASA Technical Reports Server (NTRS)
1980-01-01
The electromagnetic fields experiment on IMP-J used two electric dipole antennas and a triaxial search coil magnetic antenna to sense the electric and magnetic field of plasma waves in space. The electric dipole antennas consisted of a fine wire, 0.021 inches in diameter, with a nominal extended tip-to-tip length of 400 ft. The outermost 50 ft. of each element was conducting and the rest of the antenna was covered with an insulating coating. The search coil antennas each consisted of a high mu core with two separate windings of 40,000 turns each to sense ac magnetic fields. The search coils had a length of 18 inches tip-to-tip and are mounted on the end of a boom. The axes of the x prime and y prime search coil antennas were parallel to the x prime and y prime electric antenna axes.
NASA Astrophysics Data System (ADS)
Bolan, B. A.; Soles, C. L.; Hristov, H. A.; Gidley, D. W.; Yee, A. F.
1996-03-01
A new method is proposed for the evaluation of the hole volume in amorphous polymers based upon PALS data measured over a temperature of 110 to 480 K. Extrapolation of the "open hole" volume to 0 K allows its separation into that attributed to the segmental motions of the polymer chains (dynamic) and that due to inefficient packing (static). The dynamic hole volume is correlated to thermodynamic volume/density fluctuations and its temperature dependencies are in good agreement with SAXS data. Several thermosetting epoxy materials are also studied over a similar temperature range with the "open hole" volume being separated into its dynamic and static components. How these two components affect diffusional properties of these systems is examined in detail. It is also shown that the o-Ps can localize in a nearly 100material (PET), we therefore conclude that PALS measures more than the "free volume" necessary for segmental motion. Work supported by the Air Force Office of Scientific Research (AFOSR) grant # F49620-95-1-0037.
1977-09-09
The first Space Shuttle External Tank, the Main Propulsion Test Article (MPTA), rolls off the assembly line September 9, 1977 at the Michoud Assembly Facility in New Orleans. The MPTA was then transported to the National Space Technology Laboratories in southern Mississippi where it was used in the first static firing of the three main engines. Marshall Space Flight Center had management responsibility for Space Shuttle propulsion elements, including the External Tank. Martin Marietta was the prime contractor who designed and assembled the tanks at Michoud.
Measurements of temperature and pressure fluctuations in the T prime 2 cryogenic wind tunnel
NASA Technical Reports Server (NTRS)
Blanchard, A.; Dor, J. B.; Breil, J. F.
1980-01-01
Cold wire measurement of temperature fluctuations were made in a DERAT T'2 induction powered cryogenic wind tunnel for 2 types of liquid nitrogen injectors. Thermal turbulence measured in the tranquilization chamber depends to a great extent on the injector used; for fine spray of nitrogen drops, this level of turbulence seemed completely acceptable. Fluctuations in static pressure taken from the walls of the vein by Kulite sensors showed that there was no increase in aerodynamic noise during cryogenic gusts.
Static Properties of Fibre Metal Laminates
NASA Astrophysics Data System (ADS)
Hagenbeek, M.; van Hengel, C.; Bosker, O. J.; Vermeeren, C. A. J. R.
2003-07-01
In this article a brief overview of the static properties of Fibre Metal Laminates is given. Starting with the stress-strain relation, an effective calculation tool for uniaxial stress-strain curves is given. The method is valid for all Glare types. The Norris failure model is described in combination with a Metal Volume Fraction approach leading to a useful tool to predict allowable blunt notch strength. The Volume Fraction approach is also useful in the case of the shear yield strength of Fibre Metal Laminates. With the use of the Iosipescu test shear yield properties are measured.
Forest resources of Mississippi - 1969
Charles C. van Sickle; Dwane D. van Hooser
1969-01-01
Mississippi forests contain 15 billion cubic feet of timber growing on 17 million acres of commercial forest land. Pine volume is rising, hardwood volume is static. Growth exceeds cut but is well below attainable levels.
NASA Astrophysics Data System (ADS)
Ren, Yu; Zhou, Shimeng; Luo, Wenbo; Xue, Zhiyong; Zhang, Yajing
2018-03-01
Bimodal microstructures with primary α-phase volume fractions ranging from 14.3% to 57.1% were gained in Ti-6Al-4V (Ti-64) alloy through annealed in two-phase region at various temperatures below the β-transus point. Then the influence of the primary α-phase volume fraction on the mechanical properties of Ti-64 were studied. The results show that, at room temperature and a strain rate of 10‑3 s‑1, the yield stress decreases but the fracture strain augments with added primary α-phase volume fraction. The equiaxed primary α-phase possesses stronger ability to coordinate plastic deformation, leading to the improvement of the ductile as well as degradation of the strength of Ti-64 with higher primary α-phase volume fraction. As the temperature goes up to 473 K, the quasi-static yield stress and ultimate strength decrease first and then increase with the incremental primary α-phase volume fraction, due to the interaction between the work hardening and the softening caused by the DRX and the growth of the primary α-phase. At room temperature and a strain rate of 3×103 s‑1, the varying pattern of strength with the primary α-phase volume fraction resembles that at a quasi-static strain rate. However, the flow stress significantly increases but the strain-hardening rate decreases compared to those at quasi-static strain rate due to the competition between the strain rate hardening and the thermal softening during dynamic compression process.
Nitric Oxide Measurement Study. Volume I. Optical Calibration
1979-10-18
Comparison ......... ........................ ... 111-52 III-L Static Cell Calibration Data (NO in N2) ... .......... ... 111-62 III-M Flowing Gas Heater (FGH...appears necessary in order to continually replace the heated NO, a static heated cell would clearly be impractical. Several other calibration devices can...and Frech’s conclusions are accepted, then a static quartz cell could be used up to 1100 K only, of course, if extreme care is taken so as to avoid
Yock, Adam D; Rao, Arvind; Dong, Lei; Beadle, Beth M; Garden, Adam S; Kudchadker, Rajat J; Court, Laurence E
2014-05-01
The purpose of this work was to develop and evaluate the accuracy of several predictive models of variation in tumor volume throughout the course of radiation therapy. Nineteen patients with oropharyngeal cancers were imaged daily with CT-on-rails for image-guided alignment per an institutional protocol. The daily volumes of 35 tumors in these 19 patients were determined and used to generate (1) a linear model in which tumor volume changed at a constant rate, (2) a general linear model that utilized the power fit relationship between the daily and initial tumor volumes, and (3) a functional general linear model that identified and exploited the primary modes of variation between time series describing the changing tumor volumes. Primary and nodal tumor volumes were examined separately. The accuracy of these models in predicting daily tumor volumes were compared with those of static and linear reference models using leave-one-out cross-validation. In predicting the daily volume of primary tumors, the general linear model and the functional general linear model were more accurate than the static reference model by 9.9% (range: -11.6%-23.8%) and 14.6% (range: -7.3%-27.5%), respectively, and were more accurate than the linear reference model by 14.2% (range: -6.8%-40.3%) and 13.1% (range: -1.5%-52.5%), respectively. In predicting the daily volume of nodal tumors, only the 14.4% (range: -11.1%-20.5%) improvement in accuracy of the functional general linear model compared to the static reference model was statistically significant. A general linear model and a functional general linear model trained on data from a small population of patients can predict the primary tumor volume throughout the course of radiation therapy with greater accuracy than standard reference models. These more accurate models may increase the prognostic value of information about the tumor garnered from pretreatment computed tomography images and facilitate improved treatment management.
The possible equilibrium shapes of static pendant drops
NASA Astrophysics Data System (ADS)
Sumesh, P. T.; Govindarajan, Rama
2010-10-01
Analytical and numerical studies are carried out on the shapes of two-dimensional and axisymmetric pendant drops hanging under gravity from a solid surface. Drop shapes with both pinned and equilibrium contact angles are obtained naturally from a single boundary condition in the analytical energy optimization procedure. The numerical procedure also yields optimum energy shapes, satisfying Young's equation without the explicit imposition of a boundary condition at the plate. It is shown analytically that a static pendant two-dimensional drop can never be longer than 3.42 times the capillary length. A related finding is that a range of existing solutions for long two-dimensional drops correspond to unphysical drop shapes. Therefore, two-dimensional drops of small volume display only one static solution. In contrast, it is known that axisymmetric drops can display multiple solutions for a given volume. We demonstrate numerically that there is no limit to the height of multiple-lobed Kelvin drops, but the total volume is finite, with the volume of successive lobes forming a convergent series. The stability of such drops is in question, though. Drops of small volume can attain large heights. A bifurcation is found within the one-parameter space of Laplacian shapes, with a range of longer drops displaying a minimum in energy in the investigated space. Axisymmetric Kelvin drops exhibit an infinite number of bifurcations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haslam, J J; Wall, M A; Johnson, D L
We have measured and modeled the change in electrical resistivity due to partial transformation to the martensitic {alpha}{prime}-phase in a {delta}-phase Pu-Ga matrix. The primary objective is to relate the change in resistance, measured with a 4-probe technique during the transformation, to the volume fraction of the {alpha}{prime} phase created in the microstructure. Analysis by finite element methods suggests that considerable differences in the resistivity may be anticipated depending on the orientational and morphological configurations of the {alpha}{prime} particles. Finite element analysis of the computed resistance of an assembly of lenticular shaped particles indicates that series resistor or parallel resistormore » approximations are inaccurate and can lead to an underestimation of the predicted amount of {alpha}{prime} in the sample by 15% or more. Comparison of the resistivity of a simulated network of partially transformed grains or portions of grains suggests that a correction to the measured resistivity allows quantification of the amount of {alpha}{prime} phase in the microstructure with minimal consideration of how the {alpha}{prime} morphology may evolve. It is found that the average of the series and parallel resistor approximations provide the most accurate relationship between the measured resistivity and the amount of {alpha}{prime} phase. The methods described here are applicable to any evolving two-phase microstructure in which the resistance difference between the two phases is measurable.« less
Morrow, Melissa M.; Rankin, Jeffery W.; Neptune, Richard R.; Kaufman, Kenton R.
2014-01-01
The primary purpose of this study was to compare static and dynamic optimization muscle force and work predictions during the push phase of wheelchair propulsion. A secondary purpose was to compare the differences in predicted shoulder and elbow kinetics and kinematics and handrim forces. The forward dynamics simulation minimized differences between simulated and experimental data (obtained from 10 manual wheelchair users) and muscle co-contraction. For direct comparison between models, the shoulder and elbow muscle moment arms and net joint moments from the dynamic optimization were used as inputs into the static optimization routine. RMS errors between model predictions were calculated to quantify model agreement. There was a wide range of individual muscle force agreement that spanned from poor (26.4 % Fmax error in the middle deltoid) to good (6.4 % Fmax error in the anterior deltoid) in the prime movers of the shoulder. The predicted muscle forces from the static optimization were sufficient to create the appropriate motion and joint moments at the shoulder for the push phase of wheelchair propulsion, but showed deviations in the elbow moment, pronation-supination motion and hand rim forces. These results suggest the static approach does not produce results similar enough to be a replacement for forward dynamics simulations, and care should be taken in choosing the appropriate method for a specific task and set of constraints. Dynamic optimization modeling approaches may be required for motions that are greatly influenced by muscle activation dynamics or that require significant co-contraction. PMID:25282075
Soshi, Takahiro; Nakajima, Heizo; Hagiwara, Hiroko
2016-10-01
Static knowledge about the grammar of a natural language is represented in the cortico-subcortical system. However, the differences in dynamic verbal processing under different cognitive conditions are unclear. To clarify this, we conducted an electrophysiological experiment involving a semantic priming paradigm in which semantically congruent or incongruent word sequences (prime nouns-target verbs) were randomly presented. We examined the event-related brain potentials that occurred in response to congruent and incongruent target words that were preceded by primes with or without grammatical case markers. The two participant groups performed either the shallow (lexical judgment) or deep (direct semantic judgment) semantic tasks. We hypothesized that, irrespective of the case markers, the congruent targets would reduce centro-posterior N400 activities under the deep semantic condition, which induces selective attention to the semantic relatedness of content words. However, the same congruent targets with correct case markers would reduce lateralized negativity under the shallow semantic condition because grammatical case markers are related to automatic structural integration under semantically unattended conditions. We observed that congruent targets (e.g., 'open') that were preceded by primes with congruent case markers (e.g., 'shutter-object case') reduced lateralized negativity under the shallow semantic condition. In contrast, congruent targets, irrespective of case markers, consistently yielded N400 reductions under the deep semantic condition. To summarize, human neural verbal processing differed in response to the same grammatical markers in the same verbal expressions under semantically attended or unattended conditions.
NASA Astrophysics Data System (ADS)
Li, Yipeng; Liu, Quanzhen; Meng, He; Sun, Lifu; Zhang, Yunpeng
2013-03-01
At present Fiber Reinforced Plastics (FRP) double wall underground storage gasoline tanks are wildly used. An FRP product with a resistance of more than 1011 Ω is a static non-conductor, so it is difficult for the static electricity in the FRP product to decay into the earth. In this paper an experimental system was built to simulate an automobile gasoline filling station. Some electrostatic parameters of the gasoline, including volume charge density, were tested when gasoline was unloaded into a FRP double wall underground storage tank. Measurements were taken to make sure the volume charge density in the oil-outlet was similar to the volume charge density in the tank. In most cases the volume charge density of the gasoline was more than 22.7 μC m-3, which is likely to cause electrostatic discharge in FRP double wall underground storage gasoline tanks. On the other hand, it would be hard to ignite the vapor by electrostatic discharge since the vapor pressure in the tanks is over the explosion limit. But when the tank is repaired or re-used, the operators must pay attention to the static electricity and some measurements should be taken to avoid electrostatic accident. Besides the relaxation time of charge in the FRP double wall gasoline storage tanks should be longer.
Zheden, Vanessa; Kovalev, Alexander; Gorb, Stanislav N; Klepal, Waltraud
2015-02-06
Dosima fascicularis is the only barnacle which can drift autonomously at the water surface with a foam-like cement float. The cement secreted by the animal contains numerous gas-filled cells of different size. When several individuals share one float, their size and not their number is crucial for the production of both volume and mass of the float. The gas content within the cells of the foam gives positive static buoyancy to the whole float. The volume of the float, the gas volume and the positive static buoyancy are positively correlated. The density of the cement float without gas is greater than that of seawater. This study shows that the secreted cement consists of more than 90% water and the gas volume is on average 18.5%. Our experiments demonstrate that the intact foam-like cement float is sealed to the surrounding water.
Zheden, Vanessa; Kovalev, Alexander; Gorb, Stanislav N.; Klepal, Waltraud
2015-01-01
Dosima fascicularis is the only barnacle which can drift autonomously at the water surface with a foam-like cement float. The cement secreted by the animal contains numerous gas-filled cells of different size. When several individuals share one float, their size and not their number is crucial for the production of both volume and mass of the float. The gas content within the cells of the foam gives positive static buoyancy to the whole float. The volume of the float, the gas volume and the positive static buoyancy are positively correlated. The density of the cement float without gas is greater than that of seawater. This study shows that the secreted cement consists of more than 90% water and the gas volume is on average 18.5%. Our experiments demonstrate that the intact foam-like cement float is sealed to the surrounding water. PMID:25657839
Mocho, Pierre; Desauziers, Valérie
2011-05-01
Solid-phase microextraction (SPME) is a powerful technique, easy to implement for on-site static sampling of indoor VOCs emitted by building materials. However, a major constraint lies in the establishment of calibration curves which requires complex generation of standard atmospheres. Thus, the purpose of this paper is to propose a model to predict adsorption kinetics (i.e., calibration curves) of four model VOCs. The model is based on Fick's laws for the gas phase and on the equilibrium or the solid diffusion model for the adsorptive phase. Two samplers (the FLEC® and a home-made cylindrical emission cell), coupled to SPME for static sampling of material emissions, were studied. A good agreement between modeling and experimental data is observed and results show the influence of sampling rate on mass transfer mode in function of sample volume. The equilibrium model is adapted to quite large volume sampler (cylindrical cell) while the solid diffusion model is dedicated to small volume sampler (FLEC®). The limiting steps of mass transfer are the diffusion in gas phase for the cylindrical cell and the pore surface diffusion for the FLEC®. In the future, this modeling approach could be a useful tool for time-saving development of SPME to study building material emission in static mode sampling.
NASA Technical Reports Server (NTRS)
Koskela, P. E.
1973-01-01
This addendum to the Mariner Mars 1971 Television Picture Catalog, Volume 2 (for abstract, see N73-20850) contains data for the Mariner 9 TV pictures taken after Rev 262. Some of the data presented in Volume 2 is brought up to date. The new provisional mapping pole is discussed, and tables provide the latitude and longitude with respect to the new pole, prime meridian, and rotation rate for the centerpoints of all the Mariner 9 TV pictures.
TNT equivalency study for space shuttle (EOS). Volume 1: Management summary report
NASA Technical Reports Server (NTRS)
Wolfe, R. R.
1971-01-01
The existing TNT equivalency criterion for LO2/LH2 propellant is reevaluated. It addresses the static, on-pad phase of the space shuttle launch operations and was performed to determine whether the use of a TNT equivalency criterion lower than that presently used (60%) could be substantiated. The large quantity of propellant on-board the space shuttle, 4 million pounds, was considered of prime importance to the study. A qualitative failure analysis of the space shuttle (EOS) on the launch pad was made because it was concluded that available test data on the explosive yield of LO2/LH2 propellant was insufficient to support a reduction in the present TNT equivalency value, considering the large quantity of propellant used in the space shuttle. The failure analysis had two objectives. The first was to determine whether a failure resulting in the total release of propellant could occur. The second was to determine whether, if such a failure did occur, ignition could be delayed long enough to allow the degree of propellant mixing required to produce an explosion of 60% TNT equivalency since the explosive yield of this propellant is directly related to the quantities of LH2 and LO2 mixed at the time of the explosion.
Pre-clinical laboratory evaluation of the new 'AF' arterial line filter range.
Yarham, Gemma; Mulholland, John
2010-07-01
The presence of emboli was recognised relatively early in the history of open heart surgery. The emboli produced during cardiopulmonary bypass have the predisposition to distribute into, and ultimately obstruct, microvessels of all tissues. The Sorin Group has recently developed a new range of arterial line filters. Before the Sorin AF range of filters was released for pre-launch clinical trials, our group performed in vitro laboratory testing of the AF range against a selection of commercially available filters on the global market. The Sorin AF620 and AF640 demonstrate both the smallest prime volume and smallest surface contact area (92ml and 290 cm(2), respectively).The results of the GME Handling Efficiency experiments ranged by 39.6%, from 95.9% to 56.3%. In terms of an air bolus handling, the results of the Limit Bolus experiment ranged by 97 ml, from 147.5 ml down to 50 ml. The pressure drop across all the filters was measured under steady state experimental conditions. All of the above investigations were considered against surface area and prime volume. It is clear from the results that some commercially available arterial line filters perform better than others, not only in overall performance, but also with regard to individual characteristics. Evaluating arterial line filters for hospital-specific use has to balance pressure drop, surface area, micro air handling, prime volume and gross air handling; all points need to be considered. In the AF620 and AF640, Sorin boast that they are the two smallest prime and smallest surface area filters commercially available on the global market. The Sorin AF filter range performs well in all of the areas we investigated and will be a competitive option for centres, irrespective of which characteristics they use to evaluate and select their arterial line filter.
Mazzuco, Adriana; Medeiros, Wladimir Musetti; Sperling, Milena Pelosi Rizk; de Souza, Aline Soares; Alencar, Maria Clara Noman; Arbex, Flávio Ferlin; Neder, José Alberto; Arena, Ross; Borghi-Silva, Audrey
2015-01-01
In chronic obstructive pulmonary disease (COPD), functional and structural impairment of lung function can negatively impact heart rate variability (HRV); however, it is unknown if static lung volumes and lung diffusion capacity negatively impacts HRV responses. We investigated whether impairment of static lung volumes and lung diffusion capacity could be related to HRV indices in patients with moderate to severe COPD. Sixteen sedentary males with COPD were enrolled in this study. Resting blood gases, static lung volumes, and lung diffusion capacity for carbon monoxide (DLCO) were measured. The RR interval (RRi) was registered in the supine, standing, and seated positions (10 minutes each) and during 4 minutes of a respiratory sinus arrhythmia maneuver (M-RSA). Delta changes (Δsupine-standing and Δsupine-M-RSA) of the standard deviation of normal RRi, low frequency (LF, normalized units [nu]) and high frequency (HF [nu]), SD1, SD2, alpha1, alpha2, and approximate entropy (ApEn) indices were calculated. HF, LF, SD1, SD2, and alpha1 deltas significantly correlated with forced expiratory volume in 1 second, DLCO, airway resistance, residual volume, inspiratory capacity/total lung capacity ratio, and residual volume/total lung capacity ratio. Significant and moderate associations were also observed between LF/HF ratio versus total gas volume (%), r=0.53; LF/HF ratio versus residual volume, %, r=0.52; and HF versus total gas volume (%), r=-0.53 (P<0.05). Linear regression analysis revealed that ΔRRi supine-M-RSA was independently related to DLCO (r=-0.77, r (2)=0.43, P<0.05). Responses of HRV indices were more prominent during M-RSA in moderate to severe COPD. Moreover, greater lung function impairment was related to poorer heart rate dynamics. Finally, impaired lung diffusion capacity was related to an altered parasympathetic response in these patients.
Cardiorespiratory deconditioning with static and dynamic leg exercise during bed rest.
Stremel, R W; Convertino, V A; Bernauer, E M; Greenleaf, J E
1976-12-01
Bed rest deconditioning was assessed in seven healthy men (19-22 yr) following three 14-day periods of controlled activity during recumbency by measuring submaximal and maximal oxygen uptake (VO2), ventilation (VE), heart rate, and plasma volume. Exercise regimens were performed in the supine position and included a) two 30-min periods daily of intermittent static exercise at 21% of maximal leg extension force, and b) two 30-min periods of dynamic bicycle ergometer exercise daily at 68% of VO2max. No prescribed exercise was performed during the third bed rest period. Compared with their respective pre-bed rest control values, VO2max decreased (P less than 0.05) under all exercise conditions; -12.3% with no exercise, -9.2% with dynamic exercise, but only -4.8% with static exercise. Maximal heart rate was increased by 3.3% to 4.9% (P less than 0.05) under the three exercise conditions, while plasma volume decreased (P less than 0.05) -15.1% with no exercise and -10.1% with static, but only -7.8% (NS) with dynamic exercise. Since neither the static nor dynamic exercise training regimes minimized the changes in all the variables studied, some combination of these two types of exercise may be necessary for maximum protection from the effects of the bed deconditioning.
Kato, Nobusuke; Kawaguchi, Akira T; Kishida, Akio; Yamaoka, Tetsuji
2013-07-01
Although static cardiomyoplasty prevents the left ventricle (LV) from dilatation, it may interfere with diastolic relaxation, or cause restriction. We developed a synthetic net with dual elasticity and tested its effect late after myocardial infarction in the rat. LV pressure-volume relationships (PVR) were successively analyzed before, after intravenous volume load, and 10 minutes after occlusion of the left anterior descending artery. Rats were then randomized into groups receiving synthetic net wrapping around the heart (NET+, n = 8) and only partially behind LV (NET-, n = 9), and they underwent the same PVR studies 6 weeks later. End-diastolic and end-systolic PVR were defined, and LV size and function were compared under standardized loading conditions. Although there was no difference in Day 0, increase in LV end-diastolic and end-systolic volumes were significantly attenuated in NET+ rats 6 weeks later when there was a significant correlation between LV volumes by PVR estimation and actual measurements, with significant differences in both measures between the groups: NET+ < NET-. The presence or absence of net did not show restrictive hemodynamics under acute volume load. Static cardiomyoplasty using a synthetic elastic net significantly attenuated LV dilatation and dysfunction without restriction late after myocardial infarction in the rat. © 2013, Copyright the Authors. Artificial Organs © 2013, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Why does the lung hyperinflate?
Ferguson, Gary T
2006-04-01
Patients with chronic obstructive pulmonary disease (COPD) often have some degree of hyperinflation of the lungs. Hyperinflated lungs can produce significant detrimental effects on breathing, as highlighted by improvements in patient symptoms after lung volume reduction surgery. Measures of lung volumes correlate better with impairment of patient functional capabilities than do measures of airflow. Understanding the mechanisms by which hyperinflation occurs in COPD provides better insight into how treatments can improve patients' health. Both static and dynamic processes can contribute to lung hyperinflation in COPD. Static hyperinflation is caused by a decrease in elasticity of the lung due to emphysema. The lungs exert less recoil pressure to counter the recoil pressure of the chest wall, resulting in an equilibrium of recoil forces at a higher resting volume than normal. Dynamic hyperinflation is more common and can occur independent of or in addition to static hyperinflation. It results from air being trapped within the lungs after each breath due to a disequilibrium between the volumes inhaled and exhaled. The ability to fully exhale depends on the degree of airflow limitation and the time available for exhalation. These can both vary, causing greater hyperinflation during exacerbations or increased respiratory demand, such as during exercise. Reversibility of dynamic hyperinflation offers the possibility for intervention. Use of bronchodilators with prolonged durations of action, such as tiotropium, can sustain significant reductions in lung inflation similar in effect to lung volume reduction surgery. How efficacy of bronchodilators is assessed may, therefore, need to be reevaluated.
Sugiyama, Toshihiro; Price, Joanna S; Lanyon, Lance E
2010-02-01
In order to validate whether bones' functional adaptation to mechanical loading is a local phenomenon, we randomly assigned 21 female C57BL/6 mice at 19 weeks of age to one of three equal numbered groups. All groups were treated with isoflurane anesthesia three times a week for 2 weeks (approximately 7 min/day). During each anaesthetic period, the right tibiae/fibulae in the DYNAMIC+STATIC group were subjected to a peak dynamic load of 11.5 N (40 cycles with 10-s intervals between cycles) superimposed upon a static "pre-load" of 2.0 N. This total load of 13.5 N engendered peak longitudinal strains of approximately 1400 microstrain on the medial surface of the tibia at a middle/proximal site. The right tibiae/fibulae in the STATIC group received the static "pre-load" alone while the NOLOAD group received no artificial loading. After 2 weeks, the animals were sacrificed and both tibiae, fibulae, femora, ulnae and radii analyzed by three-dimensional high-resolution (5 mum) micro-computed tomography (microCT). In the DYNAMIC+STATIC group, the proximal trabecular percent bone volume and cortical bone volume at the proximal and middle levels of the right tibiae as well as the cortical bone volume at the middle level of the right fibulae were markedly greater than the left. In contrast, the left bones in the DYNAMIC+STATIC group showed no differences compared to the left or right bones in the NOLOAD or STATIC group. These microCT data were confirmed by two-dimensional examination of fluorochrome labels in bone sections which showed the predominantly woven nature of the new bone formed in the loaded bones. We conclude that the adaptive response in both cortical and trabecular regions of bones subjected to short periods of dynamic loading, even when this response is sufficiently vigorous to stimulate woven bone formation, is confined to the loaded bones and does not involve changes in other bones that are adjacent, contra-lateral or remote to them. (c) 2009 Elsevier Inc. All rights reserved.
Klein, Wilfried; Abe, Augusto S; Perry, Steven F
2003-04-15
The surgical removal of the post-hepatic septum (PHS) in the tegu lizard, Tupinambis merianae, significantly reduces resting lung volume (V(Lr)) and maximal lung volume (V(Lm)) when compared with tegus with intact PHS. Standardised for body mass (M(B)), static lung compliance was significantly less in tegus without PHS. Pleural and abdominal pressures followed, like ventilation, a biphasic pattern. In general, pressures increased during expiration and decreased during inspiration. However, during expiration pressure changes showed a marked intra- and interindividual variation. The removal of the PHS resulted in a lower cranio-caudal intracoelomic pressure differential, but had no effect on the general pattern of pressure changes accompanying ventilation. These results show that a perforated PHS that lacks striated muscle has significant influence on static breathing mechanics in Tupinambis and by analogy provides valuable insight into similar processes that led to the evolution of the mammalian diaphragm.
Update on alternative occupant volume testing
DOT National Transportation Integrated Search
2010-04-27
This paper describes the conduct of the first of a series of quasi-static compression tests of rail passenger equipment being done to examine occupant volume strength. Budd Pioneer car 244 has been chosen as the test article for examination of altern...
Evaluation of Occupant Volume Strength in Conventional Passenger Railroad Equipment
DOT National Transportation Integrated Search
2008-09-24
To ensure a level of occupant volume protection, passenger : railway equipment operating on mainline railroads in the : United States must be designed to resist an 800,000-lb : compressive load applied statically along the line of draft. An : alterna...
1986-04-01
Adams, R., Venna, P., Jackson, A., and Miller, R. TITLE: Plasma pharmacokinetics of intravenously administered atropine in normal human subjects Journal...atropine by i.v. route and inhalation. Measurements of respiratory airway resistance, N2 closing volume, maximal expiratory flow volume, pressure volume...maximum flow -static recoil and esophageal elasticity were compared to non-atropinized values. FINDINGS: "I.V. administration produced a marked
LOVE CANAL MONITORING PROGRAM. VOLUME 1
This report summarizes the prime contractor activities during the monitoring phase of the Love Canal project. Since GCA Corporation was only responsible for data collection, no analytical results appear in this report. The program involved a multifaceted sampling and analytical e...
NASA Technical Reports Server (NTRS)
Jaeck, C. L.
1976-01-01
A test was conducted in the Boeing Large Anechoic Chamber to determine static jet noise source locations of six baseline and suppressor nozzle models, and establish a technique for extrapolating near field data into the far field. The test covered nozzle pressure ratios from 1.44 to 2.25 and jet velocities from 412 to 594 m/s at a total temperature of 844 K.
Efficient Stochastic Rendering of Static and Animated Volumes Using Visibility Sweeps.
von Radziewsky, Philipp; Kroes, Thomas; Eisemann, Martin; Eisemann, Elmar
2017-09-01
Stochastically solving the rendering integral (particularly visibility) is the de-facto standard for physically-based light transport but it is computationally expensive, especially when displaying heterogeneous volumetric data. In this work, we present efficient techniques to speed-up the rendering process via a novel visibility-estimation method in concert with an unbiased importance sampling (involving environmental lighting and visibility inside the volume), filtering, and update techniques for both static and animated scenes. Our major contributions include a progressive estimate of partial occlusions based on a fast sweeping-plane algorithm. These occlusions are stored in an octahedral representation, which can be conveniently transformed into a quadtree-based hierarchy suited for a joint importance sampling. Further, we propose sweep-space filtering, which suppresses the occurrence of fireflies and investigate different update schemes for animated scenes. Our technique is unbiased, requires little precomputation, is highly parallelizable, and is applicable to a various volume data sets, dynamic transfer functions, animated volumes and changing environmental lighting.
1986-02-01
mechanics Eisenmann (32) established a bolted joint static strength prediction model based on fracture mechanics for composite materials. The failure...34 Composite Materials, Volume 2, Academic Press, 1974, pp. 353-431. 32. Eisenmann , J.R., "Bolted Joint Static Strength Model for Composite Materials," NASA
NASA Technical Reports Server (NTRS)
Workman, Gary L.
1990-01-01
The microstructural variations in nickel based superalloys that result from modifications in processing were examined. These superalloys include MAR-M246(HF) and PWA1480. Alternate heat treatments for equiaxed as-cast specimens were studied and a sample matrix of 42 variations in the heat treatments were processed, as well as different directional solidification parameters. Variation in temperature and times for both solution and aging were performed. Photomicrographs were made of the microstructure and volume fraction analysis of primary gamma-prime and aged gamma-prime precipitates were performed. The results of the heat treatment, cooling rate, and directional solidification experiments are discussed.
DOT National Transportation Integrated Search
1981-09-01
This profile describes and analyzes that segment of the automotive supplier industry which provides engineered mechanical components/assemblies/systems to the prime auto manufacturers. It presents an overview of the role and structure of this industr...
DOT National Transportation Integrated Search
1981-09-01
The profile describes and analyzes that segment of the automotive supplier industry which provides engineered mechanical components/assemblies/systems to the prime auto manufacturers. It presents an overview of the role and structure of this industry...
Preventive Medicine in World War II. Volume 2. Environmental Hygiene
1955-01-01
in principle of future problems. This volume is concerned with environmental hygiene and its impact upon the health, well-being, and morale of United...theater. The scope of the problem was global. Therefore, emphasis has been placed upon principles and practices peculiar to areas of the world and the...the broad application of the principles of disease preven- tion to military conditions. In such a program, one of the prime factors is environmental
DOT National Transportation Integrated Search
2008-05-31
To ensure a level of occupant volume protection, passenger railway : equipment operating on mainline railroads in the United States must currently be : designed to resist an 800,000 pound compressive load applied statically to the : underframe. An al...
Blood transfusion in pediatric cardiac surgery.
Durandy, Yves
2010-11-01
The aim of the study is to measure the volume of homologous blood needed for one pediatric patient during his hospital stay. Over a 4-month period, all the patients operated upon with a blood prime or requiring blood transfusion during their hospital stay were included in this study.The cardiopulmonary bypass protocol associates a miniaturized bypass circuit, vacuum-assisted venous drainage, and microplegia. The volume of each blood product opened is known and the volume of blood product remaining, following the last transfusion, is measured. Data collected areas follows: patient weight; hemoglobin level before surgery,during bypass, and in intensive care after the last transfusion;time to extubation; and degree of inotropic support.Forty-six patients weighing 5.1 1.5 kg were included in this study. Cardiopulmonary bypass priming volume was 100 mL for patients up to 3.5 kg, 120 mL for patients between 3.6 and 7.5 kg, and 160 mL for patients between 7.6 and 8.6 kg. The volume of blood transfusion was 271 112 mL, hemoglobin level before surgery was 10.3 1.7 g/dL, hemoglobin level during surgery was 11.0 1.5 g/dL, and hemoglobin level after the last transfusion was 12.3 2.4 g/dL. Time to extubation was 12 3.3 h, and inotropic support was enoximone in 37 patients,whereas 6 patients needed enoximone and epinephrine.No patient needed reexploration for bleeding and one patient received a platelet transfusion.The mean blood transfusion volume was equivalent to 60% of the patient’s total blood volume (estimated to be 80 mL/kg).
SU-F-T-253: Volumetric Comparison Between 4D CT Amplitude and Phase Binning Mode
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, G; Ma, R; Reyngold, M
2016-06-15
Purpose: Motion artifact in 4DCT images can affect radiation treatment quality. To identify the most robust and accurate binning method, we compare the volume difference between targets delineated on amplitude and phase binned 4DCT scans. Methods: Varian RPM system and CT scanner were used to acquire 4DCTs of a Quasar phantom with embedded cubic and spherical objects having superior-inferior motion. Eight patients’ respiration waveforms were used to drive the phantom. The 4DCT scan was reconstructed into 10 phase and 10 amplitude bins (2 mm slices). A scan of the static phantom was also acquired. For each waveform, sphere and cubemore » volumes were generated automatically on each phase using HU thresholding. Phase (amplitude) ITVs were the union of object volumes over all phase (amplitude) binned images. The sphere and cube volumes measured in the static phantom scan were V{sub sphere}=4.19cc and V{sub cube}=27.0cc. Volume difference (VD) and dice similarity coefficient (DSC) of the ITVs, and mean volume error (MVE) defined as the average target volume percentage difference between each phase image and the static image, were used to evaluate the performance of amplitude and phase binning. Results: Averaged over the eight breathing traces, the VD and DSC of the internal target volume (ITV) between amplitude and phase binning were 3.4%±3.2% (mean ± std) and 95.9%±2.1% for sphere; 2.1%±3.3% and 98.0% ±1.5% for cube, respectively.For all waveforms, the average sphere MVE of amplitude and phase binning was 6.5% ± 5.0% and 8.2%±6.3%, respectively; and the average cube MVE of amplitude and phase binning was 5.7%±3.5%and 12.9%±8.9%, respectively. Conclusion: ITV volume and spatial overlap as assessed by VD and DSC are similar between amplitude and phase binning. Compared to phase binning, amplitude binning results in lower MVE suggesting it is less susceptible to motion artifact.« less
NASA Astrophysics Data System (ADS)
Ivashchuk, V. D.; Ernazarov, K. K.
2017-01-01
A (n + 1)-dimensional gravitational model with cosmological constant and Gauss-Bonnet term is studied. The ansatz with diagonal cosmological metrics is adopted and solutions with exponential dependence of scale factors: ai ˜ exp (vit), i = 1, …, n, are considered. The stability analysis of the solutions with non-static volume factor is presented. We show that the solutions with v 1 = v 2 = v 3 = H > 0 and small enough variation of the effective gravitational constant G are stable if certain restriction on (vi ) is obeyed. New examples of stable exponential solutions with zero variation of G in dimensions D = 1 + m + 2 with m > 2 are presented.
NASA Astrophysics Data System (ADS)
de Lima, A. M. G.; Rade, D. A.; Lacerda, H. B.; Araújo, C. A.
2015-06-01
It has been demonstrated by many authors that the internal damping mechanism of the viscoelastic materials offers many possibilities for practical engineering applications. However, in traditional procedures of analysis and design of viscoelastic dampers subjected to cyclic loadings, uniform, constant temperature is generally assumed and do not take into account the self-heating phenomenon. Moreover, for viscoelastic materials subjected to dynamic loadings superimposed on static preloads, such as engine mounts, these procedures can lead to poor designs or even severe failures since the energy dissipated within the volume of the material leads to temperature rises. In this paper, a hybrid numerical-experimental investigation of effects of the static preloads on the self-heating phenomenon in viscoelastic dampers subjected to harmonic loadings is reported. After presenting the theoretical foundations, the numerical and experimental results obtained in terms of the temperature evolutions at different points within the volume of the viscoelastic material for various static preloads are compared, and the main features of the methodology are discussed.
Effective interactions and dynamics of small passive particles in an active bacterial medium
NASA Astrophysics Data System (ADS)
Semeraro, Enrico F.; Devos, Juliette M.; Narayanan, Theyencheri
2018-05-01
This article presents an investigation of the interparticle interactions and dynamics of submicron silica colloids suspended in a bath of motile Escherichia coli bacteria. The colloidal microstructure and dynamics were probed by ultra-small-angle x-ray scattering and multi-speckles x-ray photon correlation spectroscopy, respectively. Both static and hydrodynamic interactions were obtained for different colloid volume fractions and bacteria concentrations as well as when the interparticle interaction potential was modified by the motility buffer. Results suggest that motile bacteria reduce the effective attractive interactions between passive colloids and enhance their dynamics at high colloid volume fractions. The enhanced dynamics under different static interparticle interactions can be rationalized in terms of an effective viscosity of the medium and unified by means of an empirical effective temperature of the system. While the influence of swimming bacteria on the colloid dynamics is significantly lower for small particles, the role of motility buffer on the static and dynamic interactions becomes more pronounced.
Nanjappa, A; Gill, J; Sadat, U; Colah, S; Abu-Omar, Y; Nair, S
2013-11-01
Retrograde autologous priming (RAP) of the cardiopulmonary bypass (CPB) circuit could reduce the degree of haemodilution associated with priming with acellular solutions. However, there is no strong evidence to prove that the practice of RAP reduced intraoperative packed red cell (PRC) or blood product transfusion. To evaluate the effect of RAP on intraoperative PRC usage in coronary artery bypass grafting (CABG). This study is a prospective, observational study on patients who underwent first-time, isolated CABG using CPB between April 2012 and July 2012. Two groups of patients were identified: 1. Non-RAP group (n=128) and 2. RAP group (n=73). The primary outcome for the study was the amount of PRC and blood product usage between the induction of anaesthesia and the cessation of CPB. Use of PRC and blood products in the operating room was comparable in both groups. Univariate logistic regression showed that RAP was not an independent predictor of PRC or blood product transfusion (p=0.43). Multivariate logistic regression showed that CPB time, preoperative haemoglobin (Hb) levels and creatinine clearance were independent predictors of blood product transfusion. Practising RAP with mean volumes of 300 ml does not necessarily reduce PRC and other blood product transfusion requirements during CABG. In our practice, RAP was performed, aiming at displacing CPB circuit prime volume with which the perfusionist felt comfortable and dictated by haemodynamic parameters prior to commencing CPB. We presume this is the case in many units around the world. This practice, in our opinion, is not enough to achieve the benefits of RAP, if any, in the form of a reduction of packed red cell transfusion requirements. The true advantages of RAP in cardiac surgery need to be studied in a prospective, randomized, controlled trial.
The 1991 International Aerospace and Ground Conference on Lightning and Static Electricity, volume 2
NASA Technical Reports Server (NTRS)
1991-01-01
The proceedings of the conference are reported. The conference focussed on lightning protection, detection, and forecasting. The conference was divided into 26 sessions based on research in lightning, static electricity, modeling, and mapping. These sessions spanned the spectrum from basic science to engineering, concentrating on lightning prediction and detection and on safety for ground facilities, aircraft, and aerospace vehicles.
Microstructural Characterization of Aluminum-Lithium Alloys 1460 and 2195
NASA Technical Reports Server (NTRS)
Wang, Z. M.; Shenoy, R. N.
1998-01-01
Transmission electron microscopy (TEM) and differential scanning calorimetry (DSC) techniques were employed to characterize the precipitate distributions in lithium-containing aluminum alloys 1460 and 2195 in the T8 condition. TEM examinations revealed delta prime and T1 as the primary strengthening precipitates in alloys 1460 and 2195 respectively. TEM results showed a close similarity of the Russian alloy 1460 to the U.S. alloy 2090, which has a similar composition and heat treatment schedule. DSC analyses also indicate a comparable delta prime volume fraction. TEM study of a fractured tensile sample of alloy 1460 showed that delta prime precipitates are sheared by dislocations during plastic deformation and that intense stress fields arise at grain boundaries due to planar slip. Differences in fracture toughness of alloys 1460 and 2195 are rationalized on the basis of a literature review and observations from the present study.
How visual timing and form information affect speech and non-speech processing.
Kim, Jeesun; Davis, Chris
2014-10-01
Auditory speech processing is facilitated when the talker's face/head movements are seen. This effect is typically explained in terms of visual speech providing form and/or timing information. We determined the effect of both types of information on a speech/non-speech task (non-speech stimuli were spectrally rotated speech). All stimuli were presented paired with the talker's static or moving face. Two types of moving face stimuli were used: full-face versions (both spoken form and timing information available) and modified face versions (only timing information provided by peri-oral motion available). The results showed that the peri-oral timing information facilitated response time for speech and non-speech stimuli compared to a static face. An additional facilitatory effect was found for full-face versions compared to the timing condition; this effect only occurred for speech stimuli. We propose the timing effect was due to cross-modal phase resetting; the form effect to cross-modal priming. Copyright © 2014 Elsevier Inc. All rights reserved.
STATIC QUARK ANTI-QUARK FREE AND INTERNAL ENERGY IN 2-FLAVOR QCD AND BOUND STATES IN THE QGP.
DOE Office of Scientific and Technical Information (OSTI.GOV)
ZANTOW, F.; KACZMAREK, O.
2005-07-25
We present results on heavy quark free energies in 2-flavour QCD. The temperature dependence of the interaction between static quark anti-quark pairs will be analyzed in terms of temperature dependent screening radii, which give a first estimate on the medium modification of (heavy quark) bound states in the quark gluon plasma. Comparing those radii to the (zero temperature) mean squared charge radii of chasmonium states indicates that the J/{Psi} may survive the phase transition as a bound state, while {chi}{sub c} and {Psi}{prime} are expected to show significant thermal modifications at temperatures close to the transition. Furthermore we will analyzemore » the relation between heavy quark free energies, entropy contributions and internal energy and discuss their relation to potential models used to analyze the melting of heavy quark bound states above the deconfinement temperature. Results of different groups and various potential models for bound states in the deconfined phase of QCD are compared.« less
Relationship between negative affect and smoking topography in heavy drinking smokers.
Green, ReJoyce; Bujarski, Spencer; Roche, Daniel J O; Ray, Lara A
2016-10-01
Heavy drinking smokers represent a sizeable subgroup of smokers for whom nicotine deprivation and alcohol use increases the urge to smoke in the laboratory and predicts lapses during smoking cessation. The manner in which individuals smoke a cigarette (i.e. smoking topography) provides a reliable index of smoking intensity and reinforcement, yet the effects of affect on smoking topography have not been thoroughly examined in heavy drinking smokers. The current study examined how affect and nicotine deprivation predict smoking behavior as participants (N=27) smoked one cigarette using a smoking topography device after 12-h of nicotine abstinence and after a priming dose of alcohol (target BrAC=0.06g/dl). Primary smoking topography measures were puff volume, velocity, duration, and inter-puff interval (IPI). The effect of nicotine deprivation was measured by the Minnesota Nicotine Withdrawal Scale (MNWS) and the Profile of Mood States (POMS). Measures were obtained at baseline (i.e. 12-h of nicotine abstinence and pre-alcohol) and 30-minutes after alcohol administration (i.e. peak BrAC). Results revealed post-priming negative affect significantly moderated the trajectories of puff volume, puff duration and IPI (p's<0.05) over the course of the cigarette, such that those with greater negative affect had flatter slopes for volume and duration and increasingly infrequent puffs. Our results suggest that baseline and post-priming negative affect following nicotine deprivation alters smoking patterns and increases nicotine exposure throughout a single cigarette. Future studies need to examine differential amounts of nicotine deprivation on response to alcohol and smoking in heavy drinking smokers. Copyright © 2016 Elsevier Ltd. All rights reserved.
Comparison of Selected EIA-782 Data With Other Data Sources
2012-01-01
This article compares annual average prices reported from the EIA-782 survey series for residential No. 2 distillate, on-highway diesel fuel, retail regular motor gasoline, refiner No. 2 fuel oil for resale, refiner No. 2 diesel fuel for resale, refiner regular motor gasoline for resale, and refiner kerosene-type jet fuel for resale with annual average prices reported by other sources. In terms of volume, it compares EIA-782C Prime Supplier annual volumes for motor gasoline (all grades), distillate fuel oil, kerosene-type jet fuel and residual fuel oil with annual volumes from other sources.
1978-09-01
generally recognized that the best possible configura- tion for engines operating at high speeds and at high-pressure levels is probably the single...engines is invariably accom- plished by the operation of computer simulation models that generate specific numerical data rather than the generalized re...lationships common to other forms of prime mover based on units of mass or volume. Thus, providing such generalized relation- ships for a Stirling
DOE Office of Scientific and Technical Information (OSTI.GOV)
Michalski, Andrea; Central Coast Cancer Centre, Gosford Hospital, Gosford, New South Wales; Atyeo, John, E-mail: john.atyeo@sydney.edu.au
2014-07-01
Radiation therapy to the breast is a complex task, with many different techniques that can be employed to ensure adequate dose target coverage while minimizing doses to the organs at risk. This study compares the dose planning outcomes of 3 radiation treatment modalities, 3 dimensional conformal radiation therapy (3D-CRT), intensity-modulated radiation therapy (IMRT), and static tomotherapy, for left-sided whole-breast radiation treatment with a simultaneous integrated boost (SIB). Overall, 20 patients with left-sided breast cancer were separated into 2 cohorts, small and large, based on breast volume. Dose plans were produced for each patient using 3D-CRT, IMRT, and static tomotherapy. Allmore » patients were prescribed a dose of 45 Gy in 20 fractions to the breast with an SIB of 56 Gy in 20 fractions to the tumor bed and normalized so that D{sub 98%} > 95% of the prescription dose. Dosimetric comparisons were made between the 3 modalities and the interaction of patient size. All 3 modalities offered adequate planning target volume (PTV) coverage with D{sub 98%} > 95% and D{sub 2%} < 107%. Static tomotherapy offered significantly improved (p = 0.006) dose homogeneity to the PTV{sub boost} {sub eval} (0.079 ± 0.011) and breast minus the SIB volume (Breast{sub SIB}) (p < 0.001, 0.15 ± 0.03) compared with the PTV{sub boost} {sub eval} (0.085 ± 0.008, 0.088 ± 0.12) and Breast{sub SIB} (0.22 ± 0.05, 0.23 ± 0.03) for IMRT and 3D-CRT, respectively. Static tomotherapy also offered statistically significant reductions (p < 0.001) in doses to the ipsilateral lung mean dose of 6.79 ± 2.11 Gy compared with 7.75 ± 2.54 Gy and 8.29 ± 2.76 Gy for IMRT and 3D-CRT, respectively, and significantly (p < 0.001) reduced heart doses (mean = 2.83 ± 1.26 Gy) compared to both IMRT and 3D-CRT (mean = 3.70 ± 1.44 Gy and 3.91 ± 1.58 Gy). Static tomotherapy is the dosimetrically superior modality for the whole breast with an SIB compared with IMRT and 3D-CRT. IMRT is superior to 3D-CRT in both PTV dose conformity and reduction of mean doses to the ipsilateral lung.« less
Leslie, Andrew W; Lanovaz, Joel L; Andrushko, Justin W; Farthing, Jonathan P
2017-10-01
Both the repeated-bout effect and increased flexibility have been linked to reduced muscle damage, fatigue, and strength loss after intense eccentric exercise. Our purpose was to compare the eccentric-training (ECC) response after first priming the muscles with either static flexibility training or a single intense bout of eccentric exercise. Twenty-five participants were randomly assigned to flexibility training (n = 8; 3×/week; 30 min/day), a single bout of intense eccentric exercise (n = 9), or no intervention (control; n = 8) during a 4-week priming phase, prior to completing a subsequent 4-week period of eccentric training of the knee flexors. Testing was completed prior to the priming phase, before ECC, during acute ECC (0 h, 24 h, and 48 h after bouts 1 and 4), and after ECC. Measures included muscle thickness (MT; via ultrasound); isometric, concentric, and eccentric strength; muscle power (dynamometer); electromyography; range of motion; optimal angle of peak torque; and soreness (visual analog scale). Flexibility training and single-bout groups had 47% less soreness at 48 h after the first bout of ECC compared with control (p < 0.05). The flexibility training group had 10% less soreness at 48 h after the fourth ECC bout compared with both the single-bout and control groups (p < 0.05). Isometric strength loss was attenuated for the flexibility training group (-9%) after the fourth ECC bout compared with control (-19%; p < 0.05). All groups had similar increases in strength, MT, and power after ECC (p < 0.05). Prior flexibility training may be more effective than a single session of eccentric exercise in reducing adverse symptoms during the acute stages of eccentric training; however, these benefits did not translate into greater performance after training.
Cardiorespiratory deconditioning with static and dynamic leg exercise during bed rest
NASA Technical Reports Server (NTRS)
Stremel, R. W.; Convertino, V. A.; Bernauer, E. M.; Greenleaf, J. E.
1976-01-01
Results are presented for an experimental study designed to compare the effects of heavy static and dynamic exercise training during 14 days of bed rest on the cardiorespiratory responses to submaximal and maximal exercise performed by seven healthy men aged 19-22 yr. The parameters measured were submaximal and maximal oxygen uptake, minute ventilation, heart rate, and plasma volume. The results indicate that exercise alone during bed rest reduces but does not eliminate the reduction in maximal oxygen uptake. An additional positive hydrostatic effect is therefore necessary to restore maximal oxygen uptake to ambulatory control levels. The greater protective effect of static exercise on maximal oxygen uptake is probably due to a greater hydrostatic component from the isometric muscular contraction. Neither the static nor the dynamic exercise training regimes are found to minimize the changes in all the variables studied, thereby suggesting a combination of static and dynamic exercises.
A computational framework for prime implicants identification in noncoherent dynamic systems.
Di Maio, Francesco; Baronchelli, Samuele; Zio, Enrico
2015-01-01
Dynamic reliability methods aim at complementing the capability of traditional static approaches (e.g., event trees [ETs] and fault trees [FTs]) by accounting for the system dynamic behavior and its interactions with the system state transition process. For this, the system dynamics is here described by a time-dependent model that includes the dependencies with the stochastic transition events. In this article, we present a novel computational framework for dynamic reliability analysis whose objectives are i) accounting for discrete stochastic transition events and ii) identifying the prime implicants (PIs) of the dynamic system. The framework entails adopting a multiple-valued logic (MVL) to consider stochastic transitions at discretized times. Then, PIs are originally identified by a differential evolution (DE) algorithm that looks for the optimal MVL solution of a covering problem formulated for MVL accident scenarios. For testing the feasibility of the framework, a dynamic noncoherent system composed of five components that can fail at discretized times has been analyzed, showing the applicability of the framework to practical cases. © 2014 Society for Risk Analysis.
Neutron cross sections. Volume I. Resonance parameters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mughabghab, S.F.; Garber, D.I.
1973-06-01
In contrast to earlier editions, which presented in compact form a summary of the complete store of the neutron data files, this edition aims to provide those portions of neutron data considered to be of prime importance and best suited for inclusion in ready reference form. This volume contains thermal cross sections, resonance properties, resonance parameters, and bibliography for nuclides from H to /sup 257/Fm. Notation and nomenclature, considerations involved in the recommendations, and a table of energyordered resonances are also included. (RWR)
Noninvasive bi-graphical analysis for the quantification of slowly reversible radioligand binding
NASA Astrophysics Data System (ADS)
Seo, Seongho; Kim, Su Jin; Yoo, Hye Bin; Lee, Jee-Young; Kyeong Kim, Yu; Lee, Dong Soo; Zhou, Yun; Lee, Jae Sung
2016-09-01
In this paper, we presented a novel reference-region-based (noninvasive) bi-graphical analysis for the quantification of a reversible radiotracer binding that may be too slow to reach relative equilibrium (RE) state during positron emission tomography (PET) scans. The proposed method indirectly implements the noninvasive Logan plot, through arithmetic combination of the parameters of two other noninvasive methods and the apparent tissue-to-plasma efflux rate constant for the reference region (k2\\prime ). We investigated its validity and statistical properties, by performing a simulation study with various noise levels and k2\\prime values, and also evaluated its feasibility for [18F]FP-CIT PET in human brain. The results revealed that the proposed approach provides distribution volume ratio estimation comparable to the Logan plot at low noise levels while improving underestimation caused by non-RE state differently depending on k2\\prime . Furthermore, the proposed method was able to avoid noise-induced bias of the Logan plot, and the variability of its results was less dependent on k2\\prime than the Logan plot. Therefore, this approach, without issues related to arterial blood sampling given a pre-estimate of k2\\prime (e.g. population-based), could be useful in parametric image generation for slow kinetic tracers staying in a non-RE state within a PET scan.
NASA Astrophysics Data System (ADS)
Haridharan, M. K.; Bharathi Murugan, R.; Natarajan, C.; Muthukannan, M.
2017-07-01
In this paper, the experimental investigations was carried out to find the compressive strength, static modulus of elasticity and flexural strength of concrete mixtures, in which natural sand was partially replaced with Waste Tyre Crumb Rubber (WTCR). River sand was replaced with five different percentages (5%, 10%, 15%, 20% and 25%) of WTCR by volume. The main objective of the experimental investigation is to find the relationship between static modulus of elasticity and flexural strength with compressive strength of concrete with WTCR. The experimentally obtainedstatic modulus of elasticity and flexural strength results comparing with the theoretical values (various country codes recommendations).
The 1991 International Aerospace and Ground Conference on Lightning and Static Electricity, volume 1
NASA Technical Reports Server (NTRS)
1991-01-01
The proceedings of the 1991 International Aerospace and Ground Conference on Lightning and Static Electricity are reported. Some of the topics covered include: lightning, lightning suppression, aerospace vehicles, aircraft safety, flight safety, aviation meteorology, thunderstorms, atmospheric electricity, warning systems, weather forecasting, electromagnetic coupling, electrical measurement, electrostatics, aircraft hazards, flight hazards, meteorological parameters, cloud (meteorology), ground effect, electric currents, lightning equipment, electric fields, measuring instruments, electrical grounding, and aircraft instruments.
Oriented Scintillation Spectrometer Experiment (OSSE). Revision A. Volume 1
1988-05-19
SYSTEM-LEVEL ENVIRONMENTAL TESTS ................... 108 3.5.1 OPERATION REPORT, PROOF MODEL STRUCTURE TESTS.. .108 3.5.1.1 PROOF MODEL MODAL SURVEY...81 3-21 ALIGNMENT ERROR BUDGET, FOV, A4 ................ 82 3-22 ALIGNMENT ERROR BUDGET, ROTATION AXIS, A4 ...... 83 3-23 OSSE PROOF MODEL MODAL SURVEY...PROOF MODEL MODAL SURVEY .................. 112 3-27-1 OSSE PROOF MODEL STATIC LOAD TEST ............. 116 3-27-2 OSSE PROOF MODEL STATIC LOAD TEST
NASA Technical Reports Server (NTRS)
Svalbonas, V.
1973-01-01
The theoretical analysis background for the STARS-2 (shell theory automated for rotational structures) program is presented. The theory involved in the axisymmetric nonlinear and unsymmetric linear static analyses, and the stability and vibrations (including critical rotation speed) analyses involving axisymmetric prestress are discussed. The theory for nonlinear static, stability, and vibrations analyses, involving shells with unsymmetric loadings are included.
Army Sustainment. Volume 42, Issue 5, September-October 2010
2010-10-01
pollution ...creating power plants. Busi- ness prac tices that lead to increased vehicle traffic use more gasoline and create more exhaust pollution . Trash must be...replacing bottled water, which has been a prime target for environmentalists. At least one company offers a compostable plastic water bottle that
Strategic Studies Quarterly. Volume 7, Number 2, Summer 2013
2013-01-01
Handbook of Asian Regionalism Edited by: Mark Beeson and Richard Stubbs Reviewed by: Yves Laberge Maritime Challenges and Priorities in Asia...and Steven E. Miller (Cambridge, MA: MIT Press, 1993), 200-2. Van Evera in particular has opined that Europe has become "primed for peace" because
Bacterial adherence to graft tissues in static and flow conditions.
Veloso, Tiago Rafael; Claes, Jorien; Van Kerckhoven, Soetkin; Ditkowski, Bartosz; Hurtado-Aguilar, Luis G; Jockenhoevel, Stefan; Mela, Petra; Jashari, Ramadan; Gewillig, Marc; Hoylaerts, Marc F; Meyns, Bart; Heying, Ruth
2018-01-01
Various conduits and stent-mounted valves are used as pulmonary valve graft tissues for right ventricular outflow tract reconstruction with good hemodynamic results. Valve replacement carries an increased risk of infective endocarditis (IE). Recent observations have increased awareness of the risk of IE after transcatheter implantation of a stent-mounted bovine jugular vein valve. This study focused on the susceptibility of graft tissue surfaces to bacterial adherence as a potential risk factor for subsequent IE. Adhesion of Staphylococcus aureus, Staphylococcus epidermidis, and Streptococcus sanguinis to bovine pericardium (BP) patch, bovine jugular vein (BJV), and cryopreserved homograft (CH) tissues was quantified under static and shear stress conditions. Microscopic analysis and histology were performed to evaluate bacterial adhesion to matrix components. In general, similar bacteria numbers were recovered from CH and BJV tissue surfaces for all strains, especially in flow conditions. Static bacterial adhesion to the CH wall was lower for S sanguinis adhesion (P < .05 vs BP patch). Adhesion to the BJV wall, CH wall, and leaflet was decreased for S epidermidis in static conditions (P < .05 vs BP patch). Bacterial adhesion under shear stress indicated similar bacterial adhesion to all tissues, except for lower adhesion to the BJV wall after S sanguinis incubation. Microscopic analysis showed the importance of matrix component exposure for bacterial adherence to CH. Our data provide evidence that the surface composition of BJV and CH tissues themselves, bacterial surface proteins, and shear forces per se are not the prime determinants of bacterial adherence. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Silvoniemi, Antti; Din, Mueez U; Suilamo, Sami; Shepherd, Tony; Minn, Heikki
2016-11-01
Delineation of gross tumour volume in 3D is a critical step in the radiotherapy (RT) treatment planning for oropharyngeal cancer (OPC). Static [ 18 F]-FDG PET/CT imaging has been suggested as a method to improve the reproducibility of tumour delineation, but it suffers from low specificity. We undertook this pilot study in which dynamic features in time-activity curves (TACs) of [ 18 F]-FDG PET/CT images were applied to help the discrimination of tumour from inflammation and adjacent normal tissue. Five patients with OPC underwent dynamic [ 18 F]-FDG PET/CT imaging in treatment position. Voxel-by-voxel analysis was performed to evaluate seven dynamic features developed with the knowledge of differences in glucose metabolism in different tissue types and visual inspection of TACs. The Gaussian mixture model and K-means algorithms were used to evaluate the performance of the dynamic features in discriminating tumour voxels compared to the performance of standardized uptake values obtained from static imaging. Some dynamic features showed a trend towards discrimination of different metabolic areas but lack of consistency means that clinical application is not recommended based on these results alone. Impact of inflammatory tissue remains a problem for volume delineation in RT of OPC, but a simple dynamic imaging protocol proved practicable and enabled simple data analysis techniques that show promise for complementing the information in static uptake values.
NASA Technical Reports Server (NTRS)
Cerny, O. F.
1979-01-01
The paper surveys the various aspects of design and overhaul of the solid rocket boosters. It is noted that quality control is an integral part of the design specifications. Attention is given to the production process which is optimized towards highest quality. Also discussed is the role of the DCA (Defense Contract Administration) in inspecting the products of subcontractors, noting that the USAF performs this role for prime contractors. Fabrication and construction of the booster is detailed with attention given to the lining of the booster cylinder and the mixing of the propellant and the subsequent X-ray inspection.
Overlap of highly FDG-avid and FMISO hypoxic tumor subvolumes in patients with head and neck cancer.
Mönnich, David; Thorwarth, Daniela; Leibfarth, Sara; Pfannenberg, Christina; Reischl, Gerald; Mauz, Paul-Stefan; Nikolaou, Konstantin; la Fougère, Christian; Zips, Daniel; Welz, Stefan
2017-11-01
PET imaging may be used to personalize radiotherapy (RT) by identifying radioresistant tumor subvolumes for RT dose escalation. Using the tracers [ 18 F]-fluorodeoxyglucose (FDG) and [ 18 F]-fluoromisonidazole (FMISO), different aspects of tumor biology can be visualized. FDG depicts various biological aspects, e.g., proliferation, glycolysis and hypoxia, while FMISO is more hypoxia specific. In this study, we analyzed size and overlap of volumes based on the two markers for head-and-neck cancer patients (HNSCC). Twenty five HNSCC patients underwent a CT scan, as well as FDG and dynamic FMISO PET/CT prior to definitive radio-chemotherapy in a prospective FMISO dose escalation study. Three PET-based subvolumes of the primary tumor (GTV prim ) were segmented: a highly FDG-avid volume V FDG , a hypoxic volume on the static FMISO image acquired four hours post tracer injection (V H ) and a retention/perfusion volume (V M ) using pharmacokinetic modeling of dynamic FMISO data. Absolute volumes, overlaps and distances to agreement (DTA) were evaluated. Sizes of PET-based volumes and the GTV prim are significantly different (GTV prim >V FDG >V H >V M ; p < .05). V H is covered by V FDG or DTAs are small (mean coverage 74.4%, mean DTA 1.4 mm). Coverage of V M is less pronounced. With respect to V FDG and V H , the mean coverage is 48.7% and 43.1% and the mean DTA is 5.3 mm and 6.3 mm, respectively. For two patients, DTAs were larger than 2 cm. Hypoxic subvolumes from static PET imaging are typically covered by or in close proximity to highly FDG-avid subvolumes. Therefore, dose escalation to FDG positive subvolumes should cover the static hypoxic subvolumes in most patients, with the disadvantage of larger volumes, resulting in a higher risk of dose-limiting toxicity. Coverage of subvolumes from dynamic FMISO PET is less pronounced. Further studies are needed to explore the relevance of mismatches in functional imaging.
Goto, Masami; Suzuki, Makoto; Mizukami, Shinya; Abe, Osamu; Aoki, Shigeki; Miyati, Tosiaki; Fukuda, Michinari; Gomi, Tsutomu; Takeda, Tohoru
2016-10-11
An understanding of the repeatability of measured results is important for both the atlas-based and voxel-based morphometry (VBM) methods of magnetic resonance (MR) brain volumetry. However, many recent studies that have investigated the repeatability of brain volume measurements have been performed using static magnetic fields of 1-4 tesla, and no study has used a low-strength static magnetic field. The aim of this study was to investigate the repeatability of measured volumes using the atlas-based method and a low-strength static magnetic field (0.4 tesla). Ten healthy volunteers participated in this study. Using a 0.4 tesla magnetic resonance imaging (MRI) scanner and a quadrature head coil, three-dimensional T 1 -weighted images (3D-T 1 WIs) were obtained from each subject, twice on the same day. VBM8 software was used to construct segmented normalized images [gray matter (GM), white matter (WM), and cerebrospinal fluid (CSF) images]. The regions-of-interest (ROIs) of GM, WM, CSF, hippocampus (HC), orbital gyrus (OG), and cerebellum posterior lobe (CPL) were generated using WFU PickAtlas. The percentage change was defined as[100 × (measured volume with first segmented image - mean volume in each subject)/(mean volume in each subject)]The average percentage change was calculated as the percentage change in the 6 ROIs of the 10 subjects. The mean of the average percentage changes for each ROI was as follows: GM, 0.556%; WM, 0.324%; CSF, 0.573%; HC, 0.645%; OG, 1.74%; and CPL, 0.471%. The average percentage change was higher for the orbital gyrus than for the other ROIs. We consider that repeatability of the atlas-based method is similar between 0.4 and 1.5 tesla MR scanners. To our knowledge, this is the first report to show that the level of repeatability with a 0.4 tesla MR scanner is adequate for the estimation of brain volume change by the atlas-based method.
Fuld, Matthew K.; Grout, Randall; Guo, Junfeng; Morgan, John H.; Hoffman, Eric A.
2013-01-01
Rationale and Objectives Multidetector-row Computed Tomography (MDCT) has emerged as a tool for quantitative assessment of parenchymal destruction, air trapping (density metrics) and airway remodeling (metrics relating airway wall and lumen geometry) in chronic obstructive pulmonary disease (COPD) and asthma. Critical to the accuracy and interpretability of these MDCT-derived metrics is the assurance that the lungs are scanned during a breath-hold at a standardized volume. Materials and Methods A computer monitored turbine-based flow meter system was developed to control patient breath-holds and facilitate static imaging at fixed percentages of the vital capacity. Due to calibration challenges with gas density changes during multi-breath xenon-CT an alternative system was required. The design incorporated dual rolling seal pistons. Both systems were tested in a laboratory environment and human subject trials. Results The turbine-based system successfully controlled lung volumes in 32/37 subjects, having a linear relationship for CT measured air volume between repeated scans: for all scans, the mean and confidence interval of the differences (scan1-scan2) was −9 ml (−169, 151); for TLC alone 6 ml (−164, 177); for FRC alone, −23 ml (−172, 126). The dual-piston system successfully controlled lung volume in 31/41 subjects. Study failures related largely to subject non-compliance with verbal instruction and gas leaks around the mouthpiece. Conclusion We demonstrate the successful use of a turbine-based system for static lung volume control and demonstrate its inadequacies for dynamic xenon-CT studies. Implementation of a dual-rolling seal spirometer has been shown to adequately control lung volume for multi-breath wash-in xenon-CT studies. These systems coupled with proper patient coaching provide the tools for the use of CT to quantitate regional lung structure and function. The wash-in xenon-CT method for assessing regional lung function, while not necessarily practical for routine clinical studies, provides for a dynamic protocol against which newly emerging single breath, dual-energy xenon-CT measures can be validated. PMID:22555001
Fuld, Matthew K; Grout, Randall W; Guo, Junfeng; Morgan, John H; Hoffman, Eric A
2012-08-01
Multidetector-row computed tomography (MDCT) has emerged as a tool for quantitative assessment of parenchymal destruction, air trapping (density metrics), and airway remodeling (metrics relating airway wall and lumen geometry) in chronic obstructive pulmonary disease (COPD) and asthma. Critical to the accuracy and interpretability of these MDCT-derived metrics is the assurance that the lungs are scanned during a breathhold at a standardized volume. A computer monitored turbine-based flow meter system was developed to control patient breathholds and facilitate static imaging at fixed percentages of the vital capacity. Because of calibration challenges with gas density changes during multibreath xenon CT, an alternative system was required. The design incorporated dual rolling seal pistons. Both systems were tested in a laboratory environment and human subject trials. The turbine-based system successfully controlled lung volumes in 32/37 subjects, having a linear relationship for CT measured air volume between repeated scans: for all scans, the mean and confidence interval of the differences (scan1-scan2) was -9 mL (-169, 151); for total lung capacity alone 6 mL (-164, 177); for functional residual capacity alone, -23 mL (-172, 126). The dual-piston system successfully controlled lung volume in 31/41 subjects. Study failures related largely to subject noncompliance with verbal instruction and gas leaks around the mouthpiece. We demonstrate the successful use of a turbine-based system for static lung volume control and demonstrate its inadequacies for dynamic xenon CT studies. Implementation of a dual-rolling seal spirometer has been shown to adequately control lung volume for multibreath wash-in xenon CT studies. These systems coupled with proper patient coaching provide the tools for the use of CT to quantitate regional lung structure and function. The wash-in xenon CT method for assessing regional lung function, although not necessarily practical for routine clinical studies, provides for a dynamic protocol against which newly emerging single breath, dual-energy xenon CT measures can be validated. Copyright © 2012 AUR. Published by Elsevier Inc. All rights reserved.
Application of a sodium sulfur cell with dynamic sulfur electrode to a battery system
NASA Astrophysics Data System (ADS)
Tokoi, H.; Takahashi, K.; Shimoyashiki, S.
1992-01-01
The construction and performance of a sodium sulfur battery system with dynamic sulfur electrodes are described. Three cells were first connected in parallel, then two such groups were connected in series. Each cell included a liquid sodium-filled beta-double-prime-alumina tube and a system to feed liquid sulfur into the annular cathode. Low-resistance graphite felt was tightly packed around the beta-double-prime-alumina tube. Sodium pentasulfide was removed from the sulfur electrode. The battery was operated automatically and stably charged and discharged in the two-phase region. The discharged energy was 4372 Wh (capacity 1170 Ah) during a continuous operation of 19.5 h. The discharge/charge energy efficiency of the battery was 82 percent at an averaged current density of 100 mA/sq cm and operating temperature of 350 C. The deviation of the cell current in a parallel chain was less than 7 percent, and this was induced by the difference in internal resistance. In the daily charge/discharge cycle, cell capacity with the dynamic sulfur electrode was 1.5 times higher than that with the static sulfur electrode using the same active surface of beta-double-prime-alumina, because the internal resistance of the former cell was constant regardless of cell capacity. This battery system with a dynamic sulfur electrode can be applied to energy storage systems,such as large scale load leveling systems, electric vehicle batteries, and solar energy systems.
Optoelectronic system for the determination of blood volume in pneumatic heart assist devices.
Konieczny, Grzegorz; Pustelny, Tadeusz; Setkiewicz, Maciej; Gawlikowski, Maciej
2015-12-10
The following article describes the concept of optical measurement of blood volume in ventricular assist devices (VAD's) of the pulsatile type. The paper presents the current state of art in blood volume measurements of such devices and introduces a newly developed solution in the optic domain. The objective of the research is to overcome the disadvantages of the previously developed acoustic method-the requirement of additional sensor chamber. The idea of a compact measurement system has been introduced, followed by laboratory measurements. Static tests of the system have been presented, followed by dynamic measurements on a physical model of the human ventricular system. The results involving the measurements of blood chamber volume acquired by means of an optical system have been compared with the results acquired by means of the Transonic T410 ultrasound flow rate sensor (11PLX transducer, uncertainty ±5 %). Preliminary dynamic measurements conducted on the physical model of the human cardiovascular system show that the proposed optical measurement system may be used to measure the transient blood chamber volumes of pulsatile VAD's with the uncertainties (standard mean deviation) lower than 10 %. The results show that the noninvasive measurements of the temporary blood chamber volume in the POLVAD prosthesis with the use of the developed optical system allows us to carry out accurate static and dynamic measurements.
The role of perioperative chewing gum on gastric fluid volume and gastric pH: a meta-analysis.
Ouanes, Jean-Pierre P; Bicket, Mark C; Togioka, Brandon; Tomas, Vicente Garcia; Wu, Christopher L; Murphy, Jamie D
2015-03-01
To determine if preoperative gum chewing affects gastric pH and gastric fluid volume. Systematic review and meta-analysis. Data sources included Cochrane, PubMed, and EMBASE databases from inception to June 2012 and reference lists of known relevant articles without language restriction. Randomized controlled trials in which a treatment group that chewed gum was compared to a control group that fasted were included. Relevant data, including main outcomes of gastric fluid volume and gastric pH, were extracted. Four studies involving 287 patients were included. The presence of chewing gum was associated with small but statically significant increases in gastric fluid volume (mean difference = 0.21 mL/kg; 95% confidence interval, 0.02-0.39; P = .03) but not in gastric pH (mean difference = 0.11 mL/kg; 95% confidence interval, -0.14 to 0.36; P = .38). Gastric fluid volume and gastric pH remained unchanged in subgroup analysis by either sugar or sugarless gum type. Chewing gum in the perioperative period causes small but statically significant increases in gastric fluid volume and no change in gastric pH. The increase in gastric fluid most likely is of no clinical significance in terms of aspiration risk for the patient. Elective surgery should not necessarily be canceled or delayed in healthy patients who accidentally chew gum preoperatively. Copyright © 2014 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walker, Amy, E-mail: aw554@uowmail.edu.au; Metcalfe, Peter; Liney, Gary
2015-04-15
Purpose: Accurate geometry is required for radiotherapy treatment planning (RTP). When considering the use of magnetic resonance imaging (MRI) for RTP, geometric distortions observed in the acquired images should be considered. While scanner technology and vendor supplied correction algorithms provide some correction, large distortions are still present in images, even when considering considerably smaller scan lengths than those typically acquired with CT in conventional RTP. This study investigates MRI acquisition with a moving table compared with static scans for potential geometric benefits for RTP. Methods: A full field of view (FOV) phantom (diameter 500 mm; length 513 mm) was developedmore » for measuring geometric distortions in MR images over volumes pertinent to RTP. The phantom consisted of layers of refined plastic within which vitamin E capsules were inserted. The phantom was scanned on CT to provide the geometric gold standard and on MRI, with differences in capsule location determining the distortion. MRI images were acquired with two techniques. For the first method, standard static table acquisitions were considered. Both 2D and 3D acquisition techniques were investigated. With the second technique, images were acquired with a moving table. The same sequence was acquired with a static table and then with table speeds of 1.1 mm/s and 2 mm/s. All of the MR images acquired were registered to the CT dataset using a deformable B-spline registration with the resulting deformation fields providing the distortion information for each acquisition. Results: MR images acquired with the moving table enabled imaging of the whole phantom length while images acquired with a static table were only able to image 50%–70% of the phantom length of 513 mm. Maximum distortion values were reduced across a larger volume when imaging with a moving table. Increased table speed resulted in a larger contribution of distortion from gradient nonlinearities in the through-plane direction and an increased blurring of capsule images, resulting in an apparent capsule volume increase by up to 170% in extreme axial FOV regions. Blurring increased with table speed and in the central regions of the phantom, geometric distortion was less for static table acquisitions compared to a table speed of 2 mm/s over the same volume. Overall, the best geometric accuracy was achieved with a table speed of 1.1 mm/s. Conclusions: The phantom designed enables full FOV imaging for distortion assessment for the purposes of RTP. MRI acquisition with a moving table extends the imaging volume in the z direction with reduced distortions which could be useful particularly if considering MR-only planning. If utilizing MR images to provide additional soft tissue information to the planning CT, standard acquisition sequences over a smaller volume would avoid introducing additional blurring or distortions from the through-plane table movement.« less
Jerger, Susan; Tye-Murray, Nancy; Damian, Markus F.; Abdi, Hervé
2016-01-01
Objectives Our research determined 1) how phonological priming of picture naming was affected by the mode (auditory-visual [AV] vs auditory), fidelity (intact vs non-intact auditory onsets), and lexical status (words vs nonwords) of speech stimuli in children with prelingual sensorineural hearing impairment (CHI) vs. children with normal hearing (CNH); and 2) how the degree of hearing impairment (HI), auditory word recognition, and age influenced results in CHI. Note that some of our AV stimuli were not the traditional bimodal input but instead they consisted of an intact consonant/rhyme in the visual track coupled to a non-intact onset/rhyme in the auditory track. Example stimuli for the word bag are: 1) AV: intact visual (b/ag) coupled to non-intact auditory (−b/ag) and 2) Auditory: static face coupled to the same non-intact auditory (−b/ag). Our question was whether the intact visual speech would “restore or fill-in” the non-intact auditory speech in which case performance for the same auditory stimulus would differ depending upon the presence/absence of visual speech. Design Participants were 62 CHI and 62 CNH whose ages had a group-mean and -distribution akin to that in the CHI group. Ages ranged from 4 to 14 years. All participants met the following criteria: 1) spoke English as a native language, 2) communicated successfully aurally/orally, and 3) had no diagnosed or suspected disabilities other than HI and its accompanying verbal problems. The phonological priming of picture naming was assessed with the multi-modal picture word task. Results Both CHI and CNH showed greater phonological priming from high than low fidelity stimuli and from AV than auditory speech. These overall fidelity and mode effects did not differ in the CHI vs. CNH—thus these CHI appeared to have sufficiently well specified phonological onset representations to support priming and visual speech did not appear to be a disproportionately important source of the CHI’s phonological knowledge. Two exceptions occurred, however. First—with regard to lexical status—both the CHI and CNH showed significantly greater phonological priming from the nonwords than words, a pattern consistent with the prediction that children are more aware of phonetics-phonology content for nonwords. This overall pattern of similarity between the groups was qualified by the finding that CHI showed more nearly equal priming by the high vs. low fidelity nonwords than the CNH; in other words, the CHI were less affected by the fidelity of the auditory input for nonwords. Second, auditory word recognition—but not degree of HI or age—uniquely influenced phonological priming by the nonwords presented AV. Conclusions With minor exceptions, phonological priming in CHI and CNH showed more similarities than differences. Importantly, we documented that the addition of visual speech significantly increased phonological priming in both groups. Clinically these data support intervention programs that view visual speech as a powerful asset for developing spoken language in CHI. PMID:27438867
pH profile of the adsorption of nucleotides onto montmorillonite. I - Selected homoionic clays
NASA Technical Reports Server (NTRS)
Lawless, J. G.; Church, F. M.; Mazzurco, J.; Banin, A.; Huff, R.; Kao, J.; Cook, A.; Lowe, T.; Orenberg, J. B.; Edelson, E.
1985-01-01
The effect of pH and adsorbed ions on the adsorption of purine and pyrimidine nucleotides on montmorillonite clay was studied experimentally. The specific nucleotides examined were: 5 prime-AMP; 3-prime AMP; and 5 prime-CMP. The pH of the clay samples was adjusted to various levels in the 2-12 pH range using microliter volumes of concentrated acid (1N HCl) and base (1NHNaOH). It was found that preferential adsorption among nulceotides was dependent on the pH level and on the characteristics of the substituted metal cation and anion exchange mechanisms. Below pH 4, adsorption was attributed to cation and anion exchange mechanisms. Above pH 4, however, adsorption was attributed to the complexation mechanisms occurring between the metal cations in the clay exchange site and in the biomolecule. The possible role of homoionic clays in the concentration mechanisms of biomonomers in the prebiotic environment is discussed.
Journal of Special Operations Medicine. Volume 10, Edition 4, Fall 2010
2010-01-01
Prior To Ascent? ● Scapula Fracture Secondary to Static Line Injury in a 22 year-old Active Duty Soldier ● Public Health Foodborne Illness Case Study...Scapula Fracture Secondary to Static Line Injury in a 22 year-old Active Duty Soldier LTC K. David Thompson, MPAS, PA-C Public Health Foodborne Illness...consistent measurements were achieved. Predicted lung vol- ume and an appropriate densitometry equation were used to calculate percent body fat (% BF
Dynamic Response of Reinforced Soil Systems. Volume 1. Report
1993-03-01
include Security Clas~sification) DYNAMIC RWSPC!SE OF REIFý1Cý SOIL SYSTEM~, VCTJI4E I OF II: PREPO~r . PERSONAL AUTHOR($) BMW3U, R.C.; FRAWASZY...protected by a burster slab. These protection measures are costly, time consuming to construct, and sensitive to multiple strikes. Soil has been used to...characterize the static load-deflection behavior of the reinforced soil. Dynamic pullout tests were then performed using the same parameters as the static
Walk this way: approaching bodies can influence the processing of faces.
Pilz, Karin S; Vuong, Quoc C; Bülthoff, Heinrich H; Thornton, Ian M
2011-01-01
A highly familiar type of movement occurs whenever a person walks towards you. In the present study, we investigated whether this type of motion has an effect on face processing. We took a range of different 3D head models and placed them on a single, identical 3D body model. The resulting figures were animated to approach the observer. In a first series of experiments, we used a sequential matching task to investigate how the motion of an approaching person affects immediate responses to faces. We compared observers' responses following approach sequences to their performance with figures walking backwards (receding motion) or remaining still. Observers were significantly faster in responding to a target face that followed an approach sequence, compared to both receding and static primes. In a second series of experiments, we investigated long-term effects of motion using a delayed visual search paradigm. After studying moving or static avatars, observers searched for target faces in static arrays of varying set sizes. Again, observers were faster at responding to faces that had been learned in the context of an approach sequence. Together these results suggest that the context of a moving body influences face processing, and support the hypothesis that our visual system has mechanisms that aid the encoding of behaviourally-relevant and familiar dynamic events. Copyright © 2010 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blair, Shamus A.; Thakkar, Ajit J., E-mail: ajit@unb.ca
2014-08-21
Semiquantitative relationships between the mean static dipole polarizability and other molecular properties such as the volume, ionization energy, electronegativity, hardness, and moments of momentum are explored. The relationships are tested using density functional theory computations on the 1641 neutral, ground-state, organic molecules in the TABS database. The best polarizability approximations have median errors under 5%.
Blair, Shamus A; Thakkar, Ajit J
2014-08-21
Semiquantitative relationships between the mean static dipole polarizability and other molecular properties such as the volume, ionization energy, electronegativity, hardness, and moments of momentum are explored. The relationships are tested using density functional theory computations on the 1641 neutral, ground-state, organic molecules in the TABS database. The best polarizability approximations have median errors under 5%.
NASA Technical Reports Server (NTRS)
Ahmed, H.
1981-01-01
The format of computer compatible tapes which contain LANDSAT 4 and D Prime thematic mapper data is defined. A complete specification of the CCT-AT (radiometric corrections applied and geometric matrices appended) and the CCT-PT (radiometric and geometric corrections) data formats is provided.
NASA Technical Reports Server (NTRS)
Andersen, K. E.
1982-01-01
The format of high density tapes which contain partially processed LANDSAT 4 and LANDSAT D prime MSS image data is defined. This format is based on and is compatible with the existing format for partially processed LANDSAT 3 MSS image data HDTs.
Joining precipitation-hardened nickel-base alloys by friction welding
NASA Technical Reports Server (NTRS)
Moore, T. J.
1972-01-01
Solid state deformation welding process, friction welding, has been developed for joining precipitation hardened nickel-base alloys and other gamma prime-strengthened materials which heretofore have been virtually unweldable. Method requires rotation of one of the parts to be welded, but where applicable, it is an ideal process for high volume production jobs.
Redey, L.I.; Myles, K.M.; Vissers, D.R.; Prakash, J.
1996-07-02
An electrochemical cell is described with a positive electrode having an electrochemically active layer of at least one transition metal chloride. A negative electrode of an alkali metal and a compatible electrolyte including an alkali metal salt molten at cell operating temperature is included in the cell. The electrolyte is present at least partially as a corrugated {beta}{double_prime} alumina tube surrounding the negative electrode interior to the positive electrode. The ratio of the volume of liquid electrolyte to the volume of the positive electrode is in the range of from about 0.1 to about 3. A plurality of stacked electrochemical cells is disclosed each having a positive electrode, a negative electrode of an alkali metal molten at cell operating temperature, and a compatible electrolyte. The electrolyte is at least partially present as a corrugated {beta}{double_prime} alumina sheet separating the negative electrode and interior to the positive electrodes. The alkali metal is retained in a porous electrically conductive ceramic, and seals for sealing the junctures of the electrolyte and the adjacent electrodes at the peripheries thereof. 8 figs.
Concepts for Cost-Effective Enhanced Cryosat Continuity: Opportunity in the Iridium PRIME Context
NASA Astrophysics Data System (ADS)
Le Roy, Y.; Caubet, E.; Silverstrin, P.; Legrand, C.
2016-08-01
The Iridium-PRIME offer, recently initiated by the Iridium company, consists in hosting payloads on customized low cost Iridium-NEXT platforms on which the main telecom mission antenna (L-band) is removed. This leaves significant resources in terms of mass, volume and power consumption to host up to three payloads on these customized platforms. The Iridium-PRIME satellites will be inserted in the Iridium-NEXT constellation to take benefit of the low cost operation service (command, control and data telemetry through the life time of the Iridium-PRIME mission). Given the synergy between schedules of the Iridium-PRIME program (launches starting around 2020) and of a possible CryoSat Follow-On (FO) mission (launch around 2022) and the adequacy of the available on-board resources for such a mission, ESA tasked Thales Alenia Space, as responsible for the SIRAL radar instrument of the currently in-orbit CryoSat mission, to study the feasibility of a concept for enhanced continuity of CryoSat on an Iridium- PRIME satellite as potential low-cost fast-track solution. The study aimed to define a cost-effective topographic payload including not only the SIRAL radar but also the necessary sub-systems to retrieve the SIRAL antenna baseline attitude (star trackers) with high accuracy and to perform a Precise Orbit Determination (POD). All these aspects are presented in this paper. In addition, possible evolutions/improvements of the Ku-band radar instrument were analysed and are presented: adding a Ka-band nadir measurement capability and a Ku-band or Ka-band wide swath mode measurement capability. The transmission issue for the SIRAL science data is also discussed in the paper.
User's operating procedures. Volume 3: Projects directorate information programs
NASA Technical Reports Server (NTRS)
Haris, C. G.; Harris, D. K.
1985-01-01
A review of the user's operating procedures for the scout project automatic data system, called SPADS is presented. SPADS is the results of the past seven years of software development on a prime mini-computer. SPADS was developed as a single entry, multiple cross-reference data management and information retrieval system for the automation of Project office tasks, including engineering, financial, managerial, and clerical support. This volume, three of three, provides the instructions to operate the projects directorate information programs in data retrieval and file maintenance via the user friendly menu drivers.
Daneshvand, Behnaz; Ara, Katayoun Mahdavi; Raofie, Farhad
2012-08-24
Fatty acids of Cydonia oblonga Miller cultivated in Iran were obtained by supercritical (carbon dioxide) extraction and ultrasound-assisted extraction methods. The oils were analyzed by capillary gas chromatography using mass spectrometric detections. The compounds were identified according to their retention indices and mass spectra (EI, 70eV). The experimental parameters of SFE such as pressure, temperature, modifier volume, static and dynamic extraction time were optimized using a Central Composite Design (CCD) after a 2(5) factorial design. Pressure and dynamic extraction time had significant effect on the extraction yield, while the other factors (temperature, static extraction time and modifier volume) were not identified as significant factors under the selected conditions. The results of chemometrics analysis showed the highest yield for SFE (24.32%), which was obtained at a pressure of 353bar, temperature of 35°C, modifier (methanol) volume of 150μL, and static and dynamic extraction times of 10 and 60min, respectively. Ultrasound-assisted extraction (UAE) of Fatty acids from C. oblonga Miller was optimized, using a rotatable central composite design. The optimum conditions were as follows: solvent (n-hexane) volume, 22mL; extraction time, 30min; and extraction temperature, 55°C. This resulted in a maximum oil recovery of 19.5%. The extracts with higher yield from both methods were subjected to transesterification and GC-MS analysis. The results show that the oil obtained by SFE with the optimal operating conditions allowed a fatty acid composition similar to the oil obtained by UAE in optimum condition and no significant differences were found. The major components of oil extract were Linoleic, Palmitic, Oleic, Stearic and Eicosanoic acids. Copyright © 2012 Elsevier B.V. All rights reserved.
Chang, Hsun-Wen; Chieh, Hsiao-Feng; Lin, Chien-Ju; Su, Fong-Chin; Tsai, Ming-June
2014-01-01
Objectives The purpose of this study was to examine the correlation between the foot arch volume measured from static positions and the plantar pressure distribution during walking. Methods A total of 27 children, two to six years of age, were included in this study. Measurements of static foot posture were obtained, including navicular height and foot arch volume in sitting and standing positions. Plantar pressure, force and contact areas under ten different regions of the foot were obtained during walking. Results The foot arch index was correlated (r = 0.32) with the pressure difference under the midfoot during the foot flat phase. The navicular heights and foot arch volumes in sitting and standing positions were correlated with the mean forces and pressures under the first (r = −0.296∼−0.355) and second metatarsals (r = −0.335∼−0.504) and midfoot (r = −0.331∼−0.496) during the stance phase of walking. The contact areas under the foot were correlated with the foot arch parameters, except for the area under the midfoot. Conclusions The foot arch index measured in a static position could be a functional index to predict the dynamic foot functions when walking. The foot arch is a factor which will influence the pressure distribution under the foot. Children with a lower foot arch demonstrated higher mean pressure and force under the medial forefoot and midfoot, and lower contact areas under the foot, except for the midfoot region. Therefore, children with flatfoot may shift their body weight to a more medial foot position when walking, and could be at a higher risk of soft tissue injury in this area. PMID:24736650
de Moura, Mariana T M; Zanetti, Marcus V; Duran, Fabio L S; Schaufelberger, Maristela S; Menezes, Paulo R; Scazufca, Marcia; Busatto, Geraldo F; Serpa, Mauricio H
2018-01-01
White matter (WM) structural changes, particularly affecting the corpus callosum (CC), seem to be critically implicated in psychosis. Whether such abnormalities are progressive or static is still a matter of debate in schizophrenia research. Aberrant maturation processes might also influence the longitudinal trajectory of age-related CC changes in schizophrenia patients. We investigated whether patients with first-episode schizophrenia-related psychoses (FESZ) would present longitudinal CC and whole WM volume changes over the 5 years after disease onset. Thirty-two FESZ patients and 34 controls recruited using a population-based design completed a 5-year assessment protocol, including structural MRI scanning at baseline and follow-up. The linear effects of disease duration, clinical outcome and antipsychotic (AP) use over time on WM and CC volumes were studied using both voxelwise and volume-based morphometry analyses. We also examined maturation/aging abnormalities through cross-sectional analyses of age-related trajectories of total WM and CC volume changes. No interaction between diagnosis and time was observed, and clinical outcome did not influence CC volumes in patients. On the other hand, FESZ patients continuously exposed to AP medication showed volume increase over time in posterior CC. Curve-estimation analyses revealed a different aging pattern in FESZ patients versus controls: while patients displayed a linear decline of total WM and anterior CC volumes with age, a non-linear trajectory of total WM and relative preservation of CC volumes were observed in controls. Continuous AP exposure can influence CC morphology during the first years after schizophrenia onset. Schizophrenia is associated with an abnormal pattern of total WM and anterior CC aging during non-elderly adulthood, and this adds complexity to the discussion on the static or progressive nature of structural abnormalities in psychosis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Warren, J.T.
1988-01-01
A radioimmunoassay (RIA) was developed that was able to detect 40 pg meobentine (M) in 0.1 ml plasma. Cross-reactivity of suspected M metabolites was very low. This RIA was later also used to assay for fluorobentine (F), a fluorine analogue of M. M exhibits three-compartment open model iv kinetics in the rat, dog, and man. Terminal drug half-life in the rat, dog, and man; total-body clearance in the rat, dog, and man; and terminal-phase volume of distribution in the rat, dog, and man were determined. (14C)-M absorption is essentially complete in the rat and dog, but this parameter could notmore » be directly ascertained in man. Relative oral drug bioavailability is linear in the rat and dog but falls off between 5-10 mg/kg in man. F was synthesized in an attempt to counteract suspected problems with M's poor absorption or extensive metabolism that might be affecting its efficacy in humans. F would likely be unavailable for O-demethylation, might well be more lipophilic than M, and yet still be active.« less
Turbine Engine Control Synthesis. Volume 1. Optimal Controller Synthesis and Demonstration
1975-03-01
Nomenclature (Continued) Symbol Deseription M Matrix (of Table 12) M Mach number N Rotational speed, rpm N ’ Nonlinear rotational speed, rpm P Power lever... P Pressure, N /m 2; bfh/ft 2 PLA Power lever angle PR = PT3/PT2 Pressure ratio ( P Power, ft-lbf/sec Q Matrix (of Table 30) R Universal gas constant, 53...function, i = 1, 2, 3, ... in Inlet n Stage number designation out Outlet p Variable associated with particle s Static condition _se Static condition
Dosimetric feasibility of MRI-guided external beam radiotherapy of the kidney
NASA Astrophysics Data System (ADS)
Stam, Mette K.; van Vulpen, Marco; Barendrecht, Maurits M.; Zonnenberg, Bernard A.; Crijns, Sjoerd P. M.; Lagendijk, Jan J. W.; Raaymakers, Bas W.
2013-07-01
At our institution a treatment for kidney tumours with an MRI-Linac is under development. In order to set inclusion criteria for this treatment the anatomical eligibility criteria and the influence of the motion compensation strategy on the delivered dose should be known. Twenty patients with a renal lesion underwent an MR-scan to image the kidney. Static treatment plans were made and the doses to the organs at risk were evaluated. Furthermore, to calculate the influence of remnant motion in a gated treatment, a convolution of the static dose plan with the residual motion in a gating window was done. For ten patients (50%) a static plan within the dose constraints could be obtained. For all patients where the kidney constraint was obeyed in the static plan, the dose to the gross tumour volume (GTV) and the ipsilateral kidney remained within limits for residual motion in a gating window up to and including 12 mm. For four patients (20%) no static plan without violation of the constraint to the ipsilateral kidney could be made. One of these patients had a tumour of 73 mm in the upper pole and the other patients had a tumour of at least 30 mm in the mid pole. In 6 patients (30%), where the bowels were within the planning target volume, the maximum dose to the bowels was above the limit used. Patient specific assessment might degrade this violation. For tumours smaller than 30 mm a clinically acceptable plan could be created. For other patients the feasibility depends on the geometry of the GTV and kidney. Neither the GTV coverage nor the ipsilateral kidney dose is compromised by breathing motion for gating with a gating window up to and including 12 mm.
Saxena, Udit; Allan, Chris; Allen, Prudence
2017-06-01
Previous studies have suggested elevated reflex thresholds in children with auditory processing disorders (APDs). However, some aspects of the child's ear such as ear canal volume and static compliance of the middle ear could possibly affect the measurements of reflex thresholds and thus impact its interpretation. Sound levels used to elicit reflexes in a child's ear may be higher than predicted by calibration in a standard 2-cc coupler, and lower static compliance could make visualization of very small changes in impedance at threshold difficult. For this purpose, it is important to evaluate threshold data with consideration of differences between children and adults. A set of studies were conducted. The first compared reflex thresholds obtained using standard clinical procedures in children with suspected APD to that of typically developing children and adults to test the replicability of previous studies. The second study examined the impact of ear canal volume on estimates of reflex thresholds by applying real-ear corrections. Lastly, the relationship between static compliance and reflex threshold estimates was explored. The research is a set of case-control studies with a repeated measures design. The first study included data from 20 normal-hearing adults, 28 typically developing children, and 66 children suspected of having an APD. The second study included 28 normal-hearing adults and 30 typically developing children. In the first study, crossed and uncrossed reflex thresholds were measured in 5-dB step size. Reflex thresholds were analyzed using repeated measures analysis of variance (RM-ANOVA). In the second study, uncrossed reflex thresholds, real-ear correction, ear canal volume, and static compliance were measured. Reflex thresholds were measured using a 1-dB step size. The effect of real-ear correction and static compliance on reflex threshold was examined using RM-ANOVA and Pearson correlation coefficient, respectively. Study 1 replicated previous studies showing elevated reflex thresholds in many children with suspected APD when compared to data from adults using standard clinical procedures, especially in the crossed condition. The thresholds measured in children with suspected APD tended to be higher than those measured in the typically developing children. There were no significant differences between the typically developing children and adults. However, when real-ear calibrated stimulus levels were used, it was found that children's thresholds were elicited at higher levels than in the adults. A significant relationship between reflex thresholds and static compliance was found in the adult data, showing a trend for higher thresholds in ears with lower static compliance, but no such relationship was found in the data from the children. This study suggests that reflex measures in children should be adjusted for real-ear-to-coupler differences before interpretation. The data in children with suspected APD support previous studies suggesting abnormalities in reflex thresholds. The lack of correlation between threshold and static compliance estimates in children as was observed in the adults may suggest a nonmechanical explanation for age and clinically related effects. American Academy of Audiology
Development of a New Arterial-Line Filter Design Using Computational Fluid Dynamics Analysis
Herbst, Daniel P.; Najm, Hani K.
2012-01-01
Abstract: Arterial-line filters used during extracorporeal circulation continue to rely on the physical properties of a wetted micropore and reductions in blood flow velocity to affect air separation from the circulating blood volume. Although problems associated with air embolism during cardiac surgery persist, a number of investigators have concluded that further improvements in filtration are needed to enhance air removal during cardiopulmonary bypass procedures. This article reviews theoretical principles of micropore filter technology and outlines the development of a new arterial-line filter concept using computational fluid dynamics analysis. Manufacturer-supplied data of a micropore screen and experimental results taken from an ex vivo test circuit were used to define the inputs needed for numerical modeling of a new filter design. Flow patterns, pressure distributions, and velocity profiles predicted with computational fluid dynamics softwarewere used to inform decisions on model refinements and how to achieve initial design goals of ≤225 mL prime volume and ≤500 cm2 of screen surface area. Predictions for optimal model geometry included a screen angle of 56° from the horizontal plane with a total surface area of 293.9 cm2 and a priming volume of 192.4 mL. This article describes in brief the developmental process used to advance a new filter design and supports the value of numerical modeling in this undertaking. PMID:23198394
Development of a new arterial-line filter design using computational fluid dynamics analysis.
Herbst, Daniel P; Najm, Hani K
2012-09-01
Arterial-line filters used during extracorporeal circulation continue to rely on the physical properties of a wetted micropore and reductions in blood flow velocity to affect air separation from the circulating blood volume. Although problems associated with air embolism during cardiac surgery persist, a number of investigators have concluded that further improvements in filtration are needed to enhance air removal during cardiopulmonary bypass procedures. This article reviews theoretical principles of micropore filter technology and outlines the development of a new arterial-line filter concept using computational fluid dynamics analysis. Manufacturer-supplied data of a micropore screen and experimental results taken from an ex vivo test circuit were used to define the inputs needed for numerical modeling of a new filter design. Flow patterns, pressure distributions, and velocity profiles predicted with computational fluid dynamics software were used to inform decisions on model refinements and how to achieve initial design goals of < or = 225 mL prime volume and < or = 500 cm2 of screen surface area. Predictions for optimal model geometry included a screen angle of 56 degrees from the horizontal plane with a total surface area of 293.9 cm2 and a priming volume of 192.4 mL. This article describes in brief the developmental process used to advance a new filter design and supports the value of numerical modeling in this undertaking.
Arenillas, Juan F; Cortijo, Elisa; García-Bermejo, Pablo; Levy, Elad I; Jahan, Reza; Goyal, Mayank; Saver, Jeffrey L; Albers, Gregory W
2017-01-01
We aimed to evaluate how predefined candidate cerebral perfusion parameters correlate with collateral circulation status and to assess their capacity to predict infarct growth in patients with acute ischemic stroke (AIS) eligible for endovascular therapy. Patients enrolled in the SWIFT PRIME trial with baseline computed tomography perfusion (CTP) scans were included. RAPID software was used to calculate mean relative cerebral blood volume (rCBV) in hypoperfused regions, and hypoperfusion index ratio (HIR). Blind assessments of collaterals were performed using CT angiography in the whole sample and cerebral angiogram in the endovascular group. Reperfusion was assessed on 27-h CTP; infarct volume was assessed on 27-h magnetic resonance imaging/CT scans. Logistic and rank linear regression models were conducted. We included 158 patients. High rCBV ( p = 0.03) and low HIR ( p = 0.03) were associated with good collaterals. A positive association was found between rCBV and better collateral grades on cerebral angiography ( p = 0.01). Baseline and 27-h follow-up CTP were available for 115 patients, of whom 74 (64%) achieved successful reperfusion. Lower rCBV predicted a higher infarct growth in successfully reperfused patients ( p = 0.038) and in the endovascular treatment group ( p = 0.049). Finally, rCBV and HIR may serve as markers of collateral circulation in AIS patients prior to endovascular therapy. Unique identifier: NCT0165746.
In vitro performance testing of a pediatric oxygenator with an integrated pulsatile pump.
Borchardt, Ralf; Schlanstein, Peter; Mager, Ilona; Arens, Jutta; Schmitz-Rode, Thomas; Steinseifer, Ulrich
2012-01-01
For different lung and heart diseases (e.g., acute respiratory distress syndrome, congenital heart failure, and cardiomyopathy) extracorporeal membrane oxygenation is a well-established therapy, particularly in the field of neonatal and pediatric medicine. To reduce the priming volume of the extracorporeal circuit, different components can be combined. In this study, an oval-shaped oxygenator (called ExMeTrA) with integrated pulsatile pump was tested in vitro using porcine blood. A feasibility study regarding the performance of collapsing and expanding silicone tubes within an oxygenator fiber bundle as a pulsatile pump was previously completed with successful results. The findings of this study improve upon the previous feasibility results, particularly in terms of gas exchange and filling volume. Five modules were manufactured in sizes of 20 ± 2.2 ml (priming volume) with fiber surface areas of 0.24 ± 0.027 m(2) and an analytically calculated volume pumping capacity of 692 ± 75 ml/min. The modules were made of polymethylpentene fibers with dense outer layer to permit long-term applications. The gas exchange rates at a gas/blood flow ratio of 2:1 were between 64 and 72.7 ml(O)(2)/l(blood) and between 62.5 and 81.5 ml/l(blood), depending on the blood flow. The individual module's pumping capacity ranged from 200-500 ml/min thus providing room for further improvements. In order to enhance the pumping capacity while maintaining sufficient gas exchange rates future optimization, adjustments will be made to the inlet and outlet geometries.
Layered Composite Analysis Capability
NASA Technical Reports Server (NTRS)
Narayanaswami, R.; Cole, J. G.
1985-01-01
Laminated composite material construction is gaining popularity within industry as an attractive alternative to metallic designs where high strength at reduced weights is of prime consideration. This has necessitated the development of an effective analysis capability for the static, dynamic and buckling analyses of structural components constructed of layered composites. Theoretical and user aspects of layered composite analysis and its incorporation into CSA/NASTRAN are discussed. The availability of stress and strain based failure criteria is described which aids the user in reviewing the voluminous output normally produced in such analyses. Simple strategies to obtain minimum weight designs of composite structures are discussed. Several example problems are presented to demonstrate the accuracy and user convenient features of the capability.
Jeong, Heon-Ho; Lee, Byungjin; Jin, Si Hyung; Jeong, Seong-Geun; Lee, Chang-Soo
2016-04-26
Droplet-based microfluidics enabling exquisite liquid-handling has been developed for diagnosis, drug discovery and quantitative biology. Compartmentalization of samples into a large number of tiny droplets is a great approach to perform multiplex assays and to improve reliability and accuracy using a limited volume of samples. Despite significant advances in microfluidic technology, individual droplet handling in pico-volume resolution is still a challenge in obtaining more efficient and varying multiplex assays. We present a highly addressable static droplet array (SDA) enabling individual digital manipulation of a single droplet using a microvalve system. In a conventional single-layer microvalve system, the number of microvalves required is dictated by the number of operation objects; thus, individual trap-and-release on a large-scale 2D array format is highly challenging. By integrating double-layer microvalves, we achieve a "balloon" valve that preserves the pressure-on state under released pressure; this valve can allow the selective releasing and trapping of 7200 multiplexed pico-droplets using only 1 μL of sample without volume loss. This selectivity and addressability completely arranged only single-cell encapsulated droplets from a mixture of droplet compositions via repetitive selective trapping and releasing. Thus, it will be useful for efficient handling of miniscule volumes of rare or clinical samples in multiplex or combinatory assays, and the selective collection of samples.
NASA Technical Reports Server (NTRS)
1979-01-01
User power, duration, and orbit requirements, which were the prime factors influencing power extension package (PEP) design, are discussed. A representative configuration of the PEP concept is presented and the major elements of the system are described as well as the PEP-to-Orbiter and remote manipulator interface provisions.
Quasi-Static Electric Field Generator
NASA Technical Reports Server (NTRS)
Generazio, Edward R. (Inventor)
2017-01-01
A generator for producing an electric field for with an inspection technology system is provided. The generator provides the required variable magnitude quasi-static electric fields for the "illumination" of objects, areas and volumes to be inspected by the system, and produces human-safe electric fields that are only visible to the system. The generator includes a casing, a driven, non-conducting and triboelectrically neutral rotation shaft mounted therein, an ungrounded electrostatic dipole element which works in the quasi-static range, and a non-conducting support for mounting the dipole element to the shaft. The dipole element has a wireless motor system and a charging system which are wholly contained within the dipole element and the support that uses an electrostatic approach to charge the dipole element.
Common-mask guided image reconstruction (c-MGIR) for enhanced 4D cone-beam computed tomography
NASA Astrophysics Data System (ADS)
Park, Justin C.; Zhang, Hao; Chen, Yunmei; Fan, Qiyong; Li, Jonathan G.; Liu, Chihray; Lu, Bo
2015-12-01
Compared to 3D cone beam computed tomography (3D CBCT), the image quality of commercially available four-dimensional (4D) CBCT is severely impaired due to the insufficient amount of projection data available for each phase. Since the traditional Feldkamp-Davis-Kress (FDK)-based algorithm is infeasible for reconstructing high quality 4D CBCT images with limited projections, investigators had developed several compress-sensing (CS) based algorithms to improve image quality. The aim of this study is to develop a novel algorithm which can provide better image quality than the FDK and other CS based algorithms with limited projections. We named this algorithm ‘the common mask guided image reconstruction’ (c-MGIR). In c-MGIR, the unknown CBCT volume is mathematically modeled as a combination of phase-specific motion vectors and phase-independent static vectors. The common-mask matrix, which is the key concept behind the c-MGIR algorithm, separates the common static part across all phase images from the possible moving part in each phase image. The moving part and the static part of the volumes were then alternatively updated by solving two sub-minimization problems iteratively. As the novel mathematical transformation allows the static volume and moving volumes to be updated (during each iteration) with global projections and ‘well’ solved static volume respectively, the algorithm was able to reduce the noise and under-sampling artifact (an issue faced by other algorithms) to the maximum extent. To evaluate the performance of our proposed c-MGIR, we utilized imaging data from both numerical phantoms and a lung cancer patient. The qualities of the images reconstructed with c-MGIR were compared with (1) standard FDK algorithm, (2) conventional total variation (CTV) based algorithm, (3) prior image constrained compressed sensing (PICCS) algorithm, and (4) motion-map constrained image reconstruction (MCIR) algorithm, respectively. To improve the efficiency of the algorithm, the code was implemented with a graphic processing unit for parallel processing purposes. Root mean square error (RMSE) between the ground truth and reconstructed volumes of the numerical phantom were in the descending order of FDK, CTV, PICCS, MCIR, and c-MGIR for all phases. Specifically, the means and the standard deviations of the RMSE of FDK, CTV, PICCS, MCIR and c-MGIR for all phases were 42.64 ± 6.5%, 3.63 ± 0.83%, 1.31% ± 0.09%, 0.86% ± 0.11% and 0.52 % ± 0.02%, respectively. The image quality of the patient case also indicated the superiority of c-MGIR compared to other algorithms. The results indicated that clinically viable 4D CBCT images can be reconstructed while requiring no more projection data than a typical clinical 3D CBCT scan. This makes c-MGIR a potential online reconstruction algorithm for 4D CBCT, which can provide much better image quality than other available algorithms, while requiring less dose and potentially less scanning time.
Common-mask guided image reconstruction (c-MGIR) for enhanced 4D cone-beam computed tomography.
Park, Justin C; Zhang, Hao; Chen, Yunmei; Fan, Qiyong; Li, Jonathan G; Liu, Chihray; Lu, Bo
2015-12-07
Compared to 3D cone beam computed tomography (3D CBCT), the image quality of commercially available four-dimensional (4D) CBCT is severely impaired due to the insufficient amount of projection data available for each phase. Since the traditional Feldkamp-Davis-Kress (FDK)-based algorithm is infeasible for reconstructing high quality 4D CBCT images with limited projections, investigators had developed several compress-sensing (CS) based algorithms to improve image quality. The aim of this study is to develop a novel algorithm which can provide better image quality than the FDK and other CS based algorithms with limited projections. We named this algorithm 'the common mask guided image reconstruction' (c-MGIR).In c-MGIR, the unknown CBCT volume is mathematically modeled as a combination of phase-specific motion vectors and phase-independent static vectors. The common-mask matrix, which is the key concept behind the c-MGIR algorithm, separates the common static part across all phase images from the possible moving part in each phase image. The moving part and the static part of the volumes were then alternatively updated by solving two sub-minimization problems iteratively. As the novel mathematical transformation allows the static volume and moving volumes to be updated (during each iteration) with global projections and 'well' solved static volume respectively, the algorithm was able to reduce the noise and under-sampling artifact (an issue faced by other algorithms) to the maximum extent. To evaluate the performance of our proposed c-MGIR, we utilized imaging data from both numerical phantoms and a lung cancer patient. The qualities of the images reconstructed with c-MGIR were compared with (1) standard FDK algorithm, (2) conventional total variation (CTV) based algorithm, (3) prior image constrained compressed sensing (PICCS) algorithm, and (4) motion-map constrained image reconstruction (MCIR) algorithm, respectively. To improve the efficiency of the algorithm, the code was implemented with a graphic processing unit for parallel processing purposes.Root mean square error (RMSE) between the ground truth and reconstructed volumes of the numerical phantom were in the descending order of FDK, CTV, PICCS, MCIR, and c-MGIR for all phases. Specifically, the means and the standard deviations of the RMSE of FDK, CTV, PICCS, MCIR and c-MGIR for all phases were 42.64 ± 6.5%, 3.63 ± 0.83%, 1.31% ± 0.09%, 0.86% ± 0.11% and 0.52 % ± 0.02%, respectively. The image quality of the patient case also indicated the superiority of c-MGIR compared to other algorithms.The results indicated that clinically viable 4D CBCT images can be reconstructed while requiring no more projection data than a typical clinical 3D CBCT scan. This makes c-MGIR a potential online reconstruction algorithm for 4D CBCT, which can provide much better image quality than other available algorithms, while requiring less dose and potentially less scanning time.
Development of a multicomponent force and moment balance for water tunnel applications, volume 1
NASA Technical Reports Server (NTRS)
Suarez, Carlos J.; Malcolm, Gerald N.; Kramer, Brian R.; Smith, Brooke C.; Ayers, Bert F.
1994-01-01
The principal objective of this research effort was to develop a multicomponent strain gauge balance to measure forces and moments on models tested in flow visualization water tunnels. An internal balance was designed that allows measuring normal and side forces, and pitching, yawing and rolling moments (no axial force). The five-components to applied loads, low interactions between the sections and no hysteresis. Static experiments (which are discussed in this Volume) were conducted in the Eidetics water tunnel with delta wings and a model of the F/A-18. Experiments with the F/A-18 model included a thorough baseline study and investigations of the effect of control surface deflections and of several Forebody Vortex Control (FVC) techniques. Results were compared to wind tunnel data and, in general, the agreement is very satisfactory. The results of the static tests provide confidence that loads can be measured accurately in the water tunnel with a relatively simple multicomponent internal balance. Dynamic experiments were also performed using the balance, and the results are discussed in detail in Volume 2 of this report.
Gruenwald, Colleen E; McCrindle, Brian W; Crawford-Lean, Lynn; Holtby, Helen; Parshuram, Christopher; Massicotte, Patricia; Van Arsdell, Glen
2008-12-01
This study compared the effects of reconstituted fresh whole blood against standard blood component therapy in neonates undergoing cardiac surgery. Patients less than 1 month of age were randomized to receive either reconstituted fresh whole blood (n = 31) or standard blood component therapy (n = 33) to prime the bypass circuit and for transfusion during the 24 hours after cardiopulmonary bypass. Primary outcome was chest tube drainage; secondary outcomes included transfusion needs, inotrope score, ventilation time, and hospital length of stay. Patients who received reconstituted fresh whole blood had significantly less postoperative chest tube volume loss per kilogram of body weight (7.7 mL/kg vs 11.8 mL/kg; P = .03). Standard blood component therapy was associated with higher inotropic score (6.6 vs 3.3; P = .002), longer ventilation times (164 hours vs 119 hours; P = .04), as well as longer hospital stays (18 days vs 12 days; P = .006) than patients receiving reconstituted fresh whole blood. Of the different factors associated with the use of reconstituted fresh whole blood, lower platelet counts at 10 minutes and at the end of cardiopulmonary bypass, older age of cells used in the prime and throughout bypass, and exposures to higher number of allogeneic donors were found to be independent predictors of poor clinical outcomes. Reconstituted fresh whole blood used for the prime, throughout cardiopulmonary bypass, and for all transfusion requirements within the first 24 hours postoperatively results in reduced chest tube volume loss and improved clinical outcomes in neonatal patients undergoing cardiac surgery.
1976-06-01
rotating stall control system which was tested both on a low speed rig and a J-85-S engine. The second objective was to perform fundamental studies of the...Stator Stage 89 6 Annular Cascade Configuration Used for Rotating Stall Studies on Rotoi-Stator Stage ..... .............. ... 90 7 Static Pressure Rise...ground tests on a J-8S-S turbojet engine. The work i3 reported in three separate volumes. Volume I entitled, "Basic Studies of Rotating Stall", covers
Development of PRIME for irradiation performance analysis of U-Mo/Al dispersion fuel
NASA Astrophysics Data System (ADS)
Jeong, Gwan Yoon; Kim, Yeon Soo; Jeong, Yong Jin; Park, Jong Man; Sohn, Dong-Seong
2018-04-01
A prediction code for the thermo-mechanical performance of research reactor fuel (PRIME) has been developed with the implementation of developed models to analyze the irradiation behavior of U-Mo dispersion fuel. The code is capable of predicting the two-dimensional thermal and mechanical performance of U-Mo dispersion fuel during irradiation. A finite element method was employed to solve the governing equations for thermal and mechanical equilibria. Temperature- and burnup-dependent material properties of the fuel meat constituents and cladding were used. The numerical solution schemes in PRIME were verified by benchmarking solutions obtained using a commercial finite element analysis program (ABAQUS). The code was validated using irradiation data from RERTR, HAMP-1, and E-FUTURE tests. The measured irradiation data used in the validation were IL thickness, volume fractions of fuel meat constituents for the thermal analysis, and profiles of the plate thickness changes and fuel meat swelling for the mechanical analysis. The prediction results were in good agreement with the measurement data for both thermal and mechanical analyses, confirming the validity of the code.
Inspiratory Resistance as a Potential Treatment for Orthostatic Intolerance and Hemorrhagic Shock
2005-04-01
central blood volume by forcing the thoracic muscles to develop increased negative pressure , thus drawing venous blood from extrathoracic cavi- ties...cardiac baroreflex sensitivity associated with re- ductions of central blood volume during lower body negative pressure (LBNP) are reversed with...9:621–26. 8. Chapleau MW, Abboud FM. Contrasting effects of static and pulsatile pressure on carotid baroreceptor activity in dogs. Circ Res 1987; 61
NASA Astrophysics Data System (ADS)
Vickridge, Ian
2007-09-01
These two volumes present a series of papers that have arisen from a discussion meeting held at the Royal Danish Academy of Sciences and Letters in May 2006, under a strong impetus from Prof. Peter Sigmund. A significant number of central players in the 'ion beam' family were invited to participate in the discussions and most of them contributed to these two volumes. The prime purpose of the volumes, as stated in the Abstract, is 'to help those engaged in basic and applied research within ion-beam science to stay or become alert with respect to central problems in and around their area', whilst not having the pretension to be either 'a comprehensive review or a tutorial'. The overall result is stunning, and ion beam scientists from all realms are likely to want these two volumes, which together comprise some 750 pages, on their bookshelves.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pramanick, Abhijit; An, Ke; Stoica, Alexandru Dan
2011-01-01
Twin variant reorientation in single crystal Ni-Mn-Ga during quasi-static mechanical compression was studied using in-situ neutron diffraction. The volume fraction of reoriented twin variants for different stress amplitudes were obtained from the changes in integrated intensities of high-order neutron diffraction peaks. It is shown that during compressive loading, ~85% of the twins were reoriented parallel to the loading direction resulting in a maximum macroscopic strain of ~5.5%, which is in agreement with measured macroscopic strain.
1989-01-01
COMPUTER SCIENCES CORPORATION 84 B AVCO RESEARCH LABORATORY INC 109 B CONTEL FEDERAL SYSTEMS INC 439 B B D SYSTEMS INC 427 B CONTRAVES GOERZ CORPORATION...2,121 Costa Mesa California 2,026 Santa Ana California 52 450 COMPRHENSIVE TECHNOLOGIES INTL S 2,109 * Chant illy Virginia 2,109 427 CONTRAVES GOERZ
Preosteoblast production in Cosmos 2044 rats - Short-term recovery of osteogenic potential
NASA Technical Reports Server (NTRS)
Garetto, Lawrence P.; Morey, Emily R.; Durnova, G. N.; Kaplanskii, A. S.; Roberts, W. E.
1992-01-01
The influence of a 13.8-day spaceflight and about 8.5-11 h of recovery at 1 g on fibro blastlike osteoblast precursor cells was assessed in the periodontal ligament of rat maxillary first molars. Preosteoblasts (C + D cells), less differentiated progenitor cells (A + A prime cells), and nonosteogenic fibroblastlike cells (B cells) were identified by nuclear volume analysis. No differences were observed among flight, synchronous vivarium, and basal control groups in the A + A prime or C + D cell compartments. Compared with previous spaceflight experiments, the present data are consistent with a postflight response to replinish preosteoblasts and restore periodontal ligament osteogenic potential. These data emphasize the need to unequivocally determine the flight effect by killing the animals in-flight and further assess the postflight recovery phenomenon.
The effect of microstructure on 650 C fatigue crack growth in P/M Astroloy
NASA Technical Reports Server (NTRS)
Gayda, J.; Miner, R. V.
1983-01-01
The effect of microstructure on fatigue crack propagation at 650 C has been studied in a P/M nickel-base superalloy, Astroloy. Crack propagation data were obtained in air and vacuum at 20 cpm with a modified compact tension specimen. The rate of crack growth, da/dn, was correlated with the stress intensity range. Key microstructural variables examined were grain size and the distribution and size of the strengthening gamma prime phase. A fine grain size less than 20 microns always promoted rapid, intergranular failure, while a large grain size promoted slower, transgranular failure which decreased as the size and volume fraction of aging gamma prime was manipulated so as to increase alloy strength. The rapid, intergranular mode of failure of the fine grain microstructures was suppressed in vacuum.
NASA Technical Reports Server (NTRS)
Urie, D. M.
1979-01-01
Relaxed static stability and stability augmentation with active controls were investigated for subsonic transport aircraft. Analytical and simulator evaluations were done using a contemporary wide body transport as a baseline. Criteria for augmentation system performance and unaugmented flying qualities were evaluated. Augmentation control laws were defined based on selected frequency response and time history criteria. Flying qualities evaluations were conducted by pilots using a moving base simulator with a transport cab. Static margin and air turbulence intensity were varied in test with and without augmentation. Suitability of a simple pitch control law was verified at neutral static margin in cruise and landing flight tasks. Neutral stability was found to be marginally acceptable in heavy turbulence in both cruise and landing conditions.
Seki, Shiro; Tsuzuki, Seiji; Hayamizu, Kikuko; Serizawa, Nobuyuki; Ono, Shimpei; Takei, Katsuhito; Doi, Hiroyuki; Umebayashi, Yasuhiro
2014-05-01
We have measured physicochemical properties of five alkyltrimethylammonium cation-based room-temperature ionic liquids and compared them with those obtained from computational methods. We have found that static properties (density and refractive index) and transport properties (ionic conductivity, self-diffusion coefficient, and viscosity) of these ionic liquids show close relations with the length of the alkyl chain. In particular, static properties obtained by experimental methods exhibit a trend complementary to that by computational methods (refractive index ∝ [polarizability/molar volume]). Moreover, the self-diffusion coefficient obtained by molecular dynamics (MD) simulation was consistent with the data obtained by the pulsed-gradient spin-echo nuclear magnetic resonance technique, which suggests that computational methods can be supplemental tools to predict physicochemical properties of room-temperature ionic liquids.
Moens, Yves P S; Gootjes, Peter; Ionita, Jean-Claude; Heinonen, Erkki; Schatzmann, Urs
2009-05-01
To remodel and validate commercially available monitors and their Pitot tube-based flow sensors for use in large animals, using in vitro techniques. Prospective, in vitro experiment. Both the original and the remodelled sensor were studied with a reference flow generator. Measurements were taken of the static flow-pressure relationship and linearity of the flow signal. Sensor airway resistance was calculated. Following recalibration of the host monitor, volumes ranging from 1 to 7 L were generated by a calibration syringe, and bias and precision of spirometric volume was determined. Where manual recalibration was not available, a conversion factor for volume measurement was determined. The influence of gas composition mixture and peak flow on the conversion factor was studied. Both the original and the remodelled sensor showed similar static flow-pressure relationships and linearity of the flow signal. Mean bias (%) of displayed values compared with the reference volume of 3, 5 and 7 L varied between -0.4% and +2.4%, and this was significantly smaller than that for 1 L (4.8% to +5.0%). Conversion factors for 3, 5 and 7 L were very similar (mean 6.00 +/- 0.2, range 5.91-6.06) and were not significantly influenced by the gas mixture used. Increasing peak flow caused a small decrease in the conversion factor. Volume measurement error and conversion factors for inspiration and expiration were close to identity. The combination of the host monitor with the remodelled flow sensor allowed accurate in vitro measurement of flows and volumes in a range expected during large animal anaesthesia. This combination has potential as a reliable spirometric monitor for use during large animal anaesthesia.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stemkens, B; Glitzner, M; Kontaxis, C
Purpose: To assess the dose deposition in simulated single-fraction MR-Linac treatments of renal cell carcinoma, when inter-cycle respiratory motion variation is taken into account using online MRI. Methods: Three motion characterization methods, with increasing complexity, were compared to evaluate the effect of inter-cycle motion variation and drifts on the accumulated dose for an SBRT kidney MR-Linac treatment: 1) STATIC, in which static anatomy was assumed, 2) AVG-RESP, in which 4D-MRI phase-volumes were time-weighted, based on the respiratory phase and 3) PCA, in which 3D volumes were generated using a PCA-model, enabling the detection of inter-cycle variations and drifts. An experimentalmore » ITV-based kidney treatment was simulated in a 1.5T magnetic field on three volunteer datasets. For each volunteer a retrospectively sorted 4D-MRI (ten respiratory phases) and fast 2D cine-MR images (temporal resolution = 476ms) were acquired to simulate MR-imaging during radiation. For each method, the high spatio-temporal resolution 3D volumes were non-rigidly registered to obtain deformation vector fields (DVFs). Using the DVFs, pseudo-CTs (generated from the 4D-MRI) were deformed and the dose was accumulated for the entire treatment. The accuracies of all methods were independently determined using an additional, orthogonal 2D-MRI slice. Results: Motion was most accurately estimated using the PCA method, which correctly estimated drifts and inter-cycle variations (RMSE=3.2, 2.2, 1.1mm on average for STATIC, AVG-RESP and PCA, compared to the 2DMRI slice). Dose-volume parameters on the ITV showed moderate changes (D99=35.2, 32.5, 33.8Gy for STATIC, AVG-RESP and PCA). AVG-RESP showed distinct hot/cold spots outside the ITV margin, which were more distributed for the PCA scenario, since inter-cycle variations were not modeled by the AVG-RESP method. Conclusion: Dose differences were observed when inter-cycle variations were taken into account. The increased inter-cycle randomness in motion as captured by the PCA model mitigates the local (erroneous) hotspots estimated by the AVG-RESP method.« less
Comparison of stored red blood cell washing techniques for priming extracorporeal circuits.
Sasaki, Jun; Tirotta, Christopher; Lim, Hyunsoo; Kubes, Kathleen; Salvaggio, Jane; Hannan, Robert; Burke, Redmond; Ojito, Jorge
2018-03-01
The aim of this study was to compare three different blood washing techniques and describe the differences for the composition of the washed red blood cells (RBC). Stored RBCs less than 5 days old were washed using three different techniques. 1) Washing with normal saline with the COBE Model 2991 blood processor in the blood bank (BB-S). 2) Washing with normal saline with the Continuous AutoTransfusion System (C.A.T.S) in the operating room (OR-S). 3) Washing with Plasma-Lyte with the C.A.T.S in the operating room (OR-PL). Then, we compared the values for hemoglobin (Hb), hematocrit (Hct), blood volume, RBC volume, lactate, glucose, sodium and potassium of the three different groups. Forty-five units of RBCs were washed and analyzed (15 for each technique). The OR-S RBCs, when compared to the BB-S RBCs, had lower hemoglobin (g/dL) (22.8 vs 24.1, p=0.006), lower hematocrit (%) (67 vs 71, p=0.006), higher RBC volume (ml) (161 vs 130, p<0.001), higher glucose (mg/dL) (185 vs 46, p<0.001) and lower sodium (mmol/L) (153 vs 158, p<0.001). When compared to the OR-S RBCs, the OR-PL RBCs showed higher potassium (mmol/L) (5.3 vs 2, p<0.001) and lower sodium (mmol/L) (129 vs 153, p<0.001). RBCs washed with an autotransfusion device had a higher RBC volume and more physiological levels of glucose and sodium when compared with the blood processor in the blood bank. It can be an alternative option to use RBCs washed with an autotransfusion device for priming the extracorporeal circuits utilized in patients undergoing cardiac surgery.
Simon, Scott Douglas; Grey, Casey Paul
2014-04-01
The Penumbra system uses a coaxial separator and continuous extracorporeal suction to remove a clot from a cerebral artery. Forced-suction thrombectomy (FST) involves aspirating clots through the same reperfusion catheter using only a syringe, decreasing the procedure time and supplies needed. To evaluate multiple combinations of catheters and syringes to determine the optimal pairing for use in FST. Tests were performed using both the Penumbra system and syringes to aspirate water through Penumbra 0.041 inch (041), 4Max, 0.054 inch (054) and 5Max reperfusion catheters and a shuttle sheath. Dynamic pressure and flow at the catheter tip were calculated from the fill times for each system. Static pressure and force for each aspiration source were determined with a vacuum gauge. All syringes provided significantly higher dynamic pressure at the catheter tip than the Penumbra system (p<0.001). Increasing syringe volume significantly increased static pressure (p<0.001). Both flow and aspiration force significantly increased with catheter size (p<0.001). Cases are presented to demonstrate the clinical value of the laboratory principles. Maximizing static and dynamic pressure when performing FST is achieved by aspirating with a syringe possessing both the largest volume and the largest inlet diameter available. Maximizing aspiration force and flow rate is achieved by using the largest catheter possible.
NASA Astrophysics Data System (ADS)
Sharifzadeh, M.; Hashemabadi, S. H.; Afarideh, H.; Khalafi, H.
2018-02-01
The problem of how to accurately measure multiphase flow in the oil/gas industry remains as an important issue since the early 80 s. Meanwhile, oil-water two-phase flow rate measurement has been regarded as an important issue. Gamma-ray attenuation is one of the most commonly used methods for phase fraction measurement which is entirely dependent on the flow regime variations. The peripheral strategy applied for removing the regime dependency problem, is using a homogenization system as a preconditioning tool, as this research work demonstrates. Here, at first, TPFHL as a two-phase flow homogenizer loop has been introduced and verified by a quantitative assessment. In the wake of this procedure, SEMPF as a static-equivalent multiphase flow with an additional capability for preparing a uniform mixture has been explained. The proposed idea in this system was verified by Monte Carlo simulations. Finally, the different water-gas oil two-phase volume fractions fed to the homogenizer loop and injected into the static-equivalent system. A comparison between performance of these two systems by using gamma-ray attenuation technique, showed not only an extra ability to prepare a homogenized mixture but a remarkably increased measurement accuracy for the static-equivalent system.
A 4DCT imaging-based breathing lung model with relative hysteresis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miyawaki, Shinjiro; Choi, Sanghun; Hoffman, Eric A.
To reproduce realistic airway motion and airflow, the authors developed a deforming lung computational fluid dynamics (CFD) model based on four-dimensional (4D, space and time) dynamic computed tomography (CT) images. A total of 13 time points within controlled tidal volume respiration were used to account for realistic and irregular lung motion in human volunteers. Because of the irregular motion of 4DCT-based airways, we identified an optimal interpolation method for airway surface deformation during respiration, and implemented a computational solid mechanics-based moving mesh algorithm to produce smooth deforming airway mesh. In addition, we developed physiologically realistic airflow boundary conditions for bothmore » models based on multiple images and a single image. Furthermore, we examined simplified models based on one or two dynamic or static images. By comparing these simplified models with the model based on 13 dynamic images, we investigated the effects of relative hysteresis of lung structure with respect to lung volume, lung deformation, and imaging methods, i.e., dynamic vs. static scans, on CFD-predicted pressure drop. The effect of imaging method on pressure drop was 24 percentage points due to the differences in airflow distribution and airway geometry. - Highlights: • We developed a breathing human lung CFD model based on 4D-dynamic CT images. • The 4DCT-based breathing lung model is able to capture lung relative hysteresis. • A new boundary condition for lung model based on one static CT image was proposed. • The difference between lung models based on 4D and static CT images was quantified.« less
Handling Qualities Specifications for U.S. Military Helicopters
NASA Technical Reports Server (NTRS)
Key, David L.
1982-01-01
Inadequacies in the military specification for helicopter handling qualities, MIL-H-8501A, have long been recognized, and the latest procurements by the U.S. Army used special Prime Item Development Specifications (PIDS). This paper assesses the efficacy of these PIDS and suggests that changes should be made. In particular, the structure developed in MIL-F-8785B (ASG) (the specification for flying qualities of piloted airplanes) should be incorporated. Improved requirements must be based on a systematic data base and concentrated on topics most important in preliminary design: static and dynamic stability, control power and sensitivity, and interaction with controllers and displays. Emphasis should be on current military helicopter missions and helicopter idiosyncrasies such as cross-coupling, nonlinearities, and higher-order dynamics.
Mathew, L; Castillo, R; Castillo, E; Yaremko, B; Rodrigues, G; Etemad-Rezai, R; Guerrero, T; Parraga, G
2012-07-01
Dynamic imaging methods such as four-dimensional computed tomography (4DCT) and static imaging methods such as noble gas magnetic resonance imaging (MRI) deliver direct and regional measurements of lung function even in lung cancer patients in whom global lung function measurements are dominated by tumour burden. The purpose of this study was to directly compare quantitative measurements of gas distribution from static hyperpolarized 3 He MRI and dynamic 4DCT in a small group of lung cancer patients. MRI and 4DCT were performed in 11 subjects prior to radiation therapy. MRI was performed at 3.0T in breath-hold after inhalation 1L of hyperpolarized 3 He gas. Gas distribution in 3 He MRI was quantified using a semi-automated segmentation algorithm to generate percent-ventilated volume (PVV), reflecting the volume of gas in the lung normalized to the thoracic cavity volume. 4DCT pulmonary function maps were generated using deformable image registration of six expiratory phase images. The correspondence between identical tissue elements at inspiratory and expiratory phases was used to estimate regional gas distribution and PVV was quantified from these images. After accounting for differences in lung volumes between 3 He MRI (1.9±0.5L ipsilateral, 2.3±0.7 contralateral) and 4DCT (1.2±0.3L ipsilateral, 1.3±0.4L contralateral) during image acquisition, there was no statistically significant difference in PVV between 3 He MRI (72±11% ipsilateral, 79±12% contralateral) and 4DCT (74±3% ipsilateral, 75±4% contralateral). Our results indicate quantitative agreement in the regional distribution of inhaled gas in both static and dynamic imaging methods. PVV may be considered as a regional surrogate measurement of lung function or ventilation. © 2012 American Association of Physicists in Medicine.
Kvalheim, V; Farstad, M; Haugen, O; Brekke, H; Mongstad, A; Nygreen, E; Husby, P
2008-01-01
Cardiopulmonary bypass(CPB) is associated with fluid overload. We hypothesized that fluid gain during CPB could be reduced by substituting parts of a crystalloid prime with 7.2% hypertonic saline and 6% poly (O-2-hydroxyethyl) starch solution (HyperHaes). 14 animals were randomized to a control group (Group C) or to Group H. CPB-prime in Group C was Ringer's solution. In group H, 4 ml/kg of Ringer's solution was replaced by the hypertonic saline/hydroxyethyl starch solution. After 60 min stabilization, CPB was initiated and continued for 120 min. All animals were allowed drifting of normal temperature (39.0 degrees C) to about 35.0 degrees C. Fluid was added to the CPB circuit as needed to maintain a 300-ml level in the venous reservoir. Blood chemistry, hemodynamic parameters, fluid balance, plasma volume, fluid extravasation rate (FER), tissue water content and acid-base parameters were measured/calculated. Total fluid need during 120 min CPB was reduced by 60% when hypertonic saline/hydroxyethyl starch solution was added to the CPB prime (p < 0.01). The reduction was related to a lowered FER. The effect was most pronounced during the first 30 min on CPB, with 0.6 (0.43) (Group H) compared with 1.5 (0.40) ml/kg/min (Group C) (p < 0.01). Hemodynamics and laboratory parameters were similar in both groups. Serum concentrations of sodium and chloride increased to maximum levels of 148 (1.5) and 112 (1.6) mmol/l in Group H. To conclude: addition of 7.2% hypertonic saline and 6% poly (O-2-hydroxyethyl) starch solution to crystalloid CPB prime reduces fluid needs and FER during tepid CPB.
Morris, Mohy G.
2009-01-01
With the rapid somatic growth and development in infants, simultaneous accurate measurements of lung volume and airway function are essential. Raised volume rapid thoracoabdominal compression (RTC) is widely used to generate forced expiration from an airway opening pressure of 30 cm H2O (V30). The (dynamic) functional residual capacity (FRCdyn) remains the lung volume most routinely measured. The aim of this study was to develop comprehensive integrated spirometry that included all subdivisions of lung volume at V30 or total lung capacity (TLC30). Measurements were performed on seventeen healthy infants aged 8.6–119.7 weeks. A commercial system for multiple-breath nitrogen washout (MBNW) to measure lung volumes and a custom made system to perform RTC were used in unison. A refined automated raised volume RTC and the following two novel single maneuvers with dual volume measurements were performed from V30 during a brief post-hyperventilation apneic pause: (1) the passive expiratory flow was integrated to produce the inspiratory capacity (IC) and the static (passive) FRC (FRCst) was estimated by initiating MBNW after end-passive expiration; (2) RTC was initiated late during passive expiration, flow was integrated to produce the slow vital capacity (jSVC) and the residual volume (RV) was measured by initiating MBNW after end-expiration while the jacket (j) was inflated. Intrasubject FRCdyn and FRCst measurements overlapped (p= 0.6420) but neither did with the RV (p<0.0001). Means (95% confidence interval) of FRCdyn, IC, FRCst, jSVC, RV, forced vital capacity and tidal volume were 21.2 (19.7–22.7), 36.7 (33.0–40.4), 21.2 (19.6–22.8), 40.7 (37.2–44.2), 18.1 (16.6–19.7), 40.7 (37.1–44.2) and 10.2 (9.6–10.7) ml/kg, respectively. Static lung volumes and capacities at V30 and variables from the best forced expiratory flow-volume curve were dependent on age, body length and weight. In conclusion, we developed a comprehensive physiologically-integrated approach for in-depth investigation of lung function at V30 in infants. PMID:19897058
Efficient low static-volume water heater
NASA Technical Reports Server (NTRS)
Brown, R. L.
1976-01-01
Calrod heating element is surrounded by matrix of fused sintered copper or brass balls, and assembly is then installed in piping of water system. As water flows through matrix, sintered balls cause turbulent flow and heating. Applications include laundromats, laboratories, and photographic labs.
100 Companies Receiving the Largest Dollar Volume of Prime Contract Awards, fiscal Year 1989
1989-01-01
Fiscal Year 1989 Accession For NTIS GRA&I DTIC TAB0 Unannounced ju3t if iat ion Distribution/ AvailabilitY Codes Dit special. TABLE OF CONTENTS Invir...CORPORATION 9,625 TOTAL 118,089 0.09 66.11 98 CONTINENTAL MARITIME INDS 33,818 CONTINNTAL MRTIME OF SAN DIEGO 82,791 TOTAL 116,609 0 09 66.20 99
Huebler, Michael; Boettcher, Wolfgang; Koster, Andreas; Stiller, Brigitte; Kuppe, Hermann; Hetzer, Roland
2007-01-01
Herein, we describe the design of a perfusion system for a complex cardiovascular reoperation in an 11-kg Jehovah's Witness patient. The goal of safe, transfusion-free surgery was achieved chiefly by minimizing the priming volume of the cardiopulmonary bypass circuit to 200 mL while providing adequate flow and standard safety features.
Earth Observing System. Science and Mission Requirements, Volume 1, Part 1
NASA Technical Reports Server (NTRS)
1984-01-01
The Earth Observing System (EOS) is a planned NASA program, which will carry the multidisciplinary Earth science studies employing a variety of remote sensing techniques in the 1990's, as a prime mission, using the Space Station polar platform. The scientific rationale, recommended observational needs, the broad system configuration and a recommended implementation strategy to achieve the stated mission goals are provided.
Recurrent competition explains temporal effects of attention in MSTd
Layton, Oliver W.; Browning, N. Andrew
2012-01-01
Navigation in a static environment along straight paths without eye movements produces radial optic flow fields. A singularity called the focus of expansion (FoE) specifies the direction of travel (heading) of the observer. Cells in primate dorsal medial superior temporal area (MSTd) respond to radial fields and are therefore thought to be heading-sensitive. Humans frequently shift their focus of attention while navigating, for example, depending on the favorable or threatening context of approaching independently moving objects. Recent neurophysiological studies show that the spatial tuning curves of primate MSTd neurons change based on the difference in visual angle between an attentional prime and the FoE. Moreover, the peak mean population activity in MSTd retreats linearly in time as the distance between the attentional prime and FoE increases. We present a dynamical neural circuit model that demonstrates the same linear temporal peak shift observed electrophysiologically. The model qualitatively matches the neuron tuning curves and population activation profiles. After model MT dynamically pools short-range motion, model MSTd incorporates recurrent competition between units tuned to different radial optic flow templates, and integrates attentional signals from model area frontal eye fields (FEF). In the model, population activity peaks occur when the recurrent competition is most active and uncertainty is greatest about the relative position of the FoE. The nature of attention, multiplicative or non-multiplicative, is largely irrelevant, so long as attention has a Gaussian-like profile. Using an appropriately tuned sigmoidal signal function to modulate recurrent feedback affords qualitative fits of deflections in the population activity that otherwise appear to be low-frequency noise. We predict that these deflections mark changes in the balance of attention between the priming and FoE locations. PMID:23060788
Boucher, Yves; Moreau, Nathan; Mauborgne, Annie; Dieb, Wisam
2018-06-18
We explored the molecular and behavioral effects of a perineural Lipopolysaccharide (LPS)-mediated inflammatory priming on the development and maintenance of painful post-traumatic trigeminal neuropathy (PPTTN) following infra-orbital nerve chronic constriction injury (CCI-IoN) in rats. Rats were pretreated with repetitive perineural injections in the vicinity of the IoN of either LPS or vehicle (Vhcl) before being submitted to CCI-IoN. Orofacial pain-like behaviors (response to Von Frey Filament testing and spontaneous isolated face grooming) were measured during the period of LPS injections (three weeks) and following CCI-IoN surgery (two weeks). Local LPS administration induced an early pain-like behavior (i.e. an increase in spontaneous pain [SP] or mechanical static allodynia [MSA]) in both conditions, and following CCI-IoN, MSA and SP developed earlier and more severely in LPS-pretreated rats than in the control group. Ipsilateral increases of key neuropathic pain mRNA markers in the IoN parenchyma, trigeminal ganglia (TG) and spinal trigeminal nucleus caudalis (Sp5C) were observed in CCI-IoN injured animals as compared to controls. Although no significant molecular differences could be observed within the IoN parenchyma between LPS and Vhcl-pretreated animals, a significant increase of key inflammatory cytokine Interleukin 1 beta (IL - 1β) could be found in the TG of LPS-pretreated CCI-injured animals versus controls. Finally, a higher increase of inducible nitric oxide synthase (iNOS) in ipsilateral Sp5C of LPS-pretreated animals was observed as compared to Sp5C of Vhcl-pretreated animals. These results suggest a key role of inflammatory priming in the development and maintenance of PPTTN implicating IL-1β/iNOS-dependent central sensitization mechanisms. Copyright © 2018. Published by Elsevier Inc.
1980-01-31
VOLUME II NPART.I CSOMPON;-ETC(U) NCASFE JAN 80 000G3 79 C-0329 m h mh8 06GU DI NL NB UN EH E SP EK EI ST UM N hD Vh ml1/ 1 . 1111"?.5 ggl g $.0 111112...diameter cables, * Complex-low reliability Iris incl. continuously variable e Med to High leakage * Large envelope reqd. * Static Seal, 2- Porn ., o Can
Nolte, Guido
2003-11-21
The equation for the magnetic lead field for a given magnetoencephalography (MEG) channel is well known for arbitrary frequencies omega but is not directly applicable to MEG in the quasi-static approximation. In this paper we derive an equation for omega = 0 starting from the very definition of the lead field instead of using Helmholtz's reciprocity theorems. The results are (a) the transpose of the conductivity times the lead field is divergence-free, and (b) the lead field differs from the one in any other volume conductor by a gradient of a scalar function. Consequently, for a piecewise homogeneous and isotropic volume conductor, the lead field is always tangential at the outermost surface. Based on this theoretical result, we formulated a simple and fast method for the MEG forward calculation for one shell of arbitrary shape: we correct the corresponding lead field for a spherical volume conductor by a superposition of basis functions, gradients of harmonic functions constructed here from spherical harmonics, with coefficients fitted to the boundary conditions. The algorithm was tested for a prolate spheroid of realistic shape for which the analytical solution is known. For high order in the expansion, we found the solutions to be essentially exact and for reasonable accuracies much fewer multiplications are needed than in typical implementations of the boundary element methods. The generalization to more shells is straightforward.
Sera, Toshihiro; Yokota, Hideo; Tanaka, Gaku; Uesugi, Kentaro; Yagi, Naoto; Schroter, Robert C
2013-07-15
We visualized pulmonary acini in the core regions of the mouse lung in situ using synchrotron refraction-enhanced computed tomography (CT) and evaluated their kinematics during quasi-static inflation. This CT system (with a cube voxel of 2.8 μm) allows excellent visualization of not just the conducting airways, but also the alveolar ducts and sacs, and tracking of the acinar shape and its deformation during inflation. The kinematics of individual alveoli and alveolar clusters with a group of terminal alveoli is influenced not only by the connecting alveolar duct and alveoli, but also by the neighboring structures. Acinar volume was not a linear function of lung volume. The alveolar duct diameter changed dramatically during inflation at low pressures and remained relatively constant above an airway pressure of ∼8 cmH2O during inflation. The ratio of acinar surface area to acinar volume indicates that acinar distension during low-pressure inflation differed from that during inflation over a higher pressure range; in particular, acinar deformation was accordion-like during low-pressure inflation. These results indicated that the alveoli and duct expand differently as total acinar volume increases and that the alveolar duct may expand predominantly during low-pressure inflation. Our findings suggest that acinar deformation in the core regions of the lung is complex and heterogeneous.
User's operating procedures. Volume 2: Scout project financial analysis program
NASA Technical Reports Server (NTRS)
Harris, C. G.; Haris, D. K.
1985-01-01
A review is presented of the user's operating procedures for the Scout Project Automatic Data system, called SPADS. SPADS is the result of the past seven years of software development on a Prime mini-computer located at the Scout Project Office, NASA Langley Research Center, Hampton, Virginia. SPADS was developed as a single entry, multiple cross-reference data management and information retrieval system for the automation of Project office tasks, including engineering, financial, managerial, and clerical support. This volume, two (2) of three (3), provides the instructions to operate the Scout Project Financial Analysis program in data retrieval and file maintenance via the user friendly menu drivers.
Wave energy absorption by a submerged air bag connected to a rigid float.
Kurniawan, A; Chaplin, J R; Hann, M R; Greaves, D M; Farley, F J M
2017-04-01
A new wave energy device features a submerged ballasted air bag connected at the top to a rigid float. Under wave action, the bag expands and contracts, creating a reciprocating air flow through a turbine between the bag and another volume housed within the float. Laboratory measurements are generally in good agreement with numerical predictions. Both show that the trajectory of possible combinations of pressure and elevation at which the device is in static equilibrium takes the shape of an S. This means that statically the device can have three different draughts, and correspondingly three different bag shapes, for the same pressure. The behaviour in waves depends on where the mean pressure-elevation condition is on the static trajectory. The captured power is highest for a mean condition on the middle section.
Wave energy absorption by a submerged air bag connected to a rigid float
Chaplin, J. R.; Hann, M. R.; Greaves, D. M.; Farley, F. J. M.
2017-01-01
A new wave energy device features a submerged ballasted air bag connected at the top to a rigid float. Under wave action, the bag expands and contracts, creating a reciprocating air flow through a turbine between the bag and another volume housed within the float. Laboratory measurements are generally in good agreement with numerical predictions. Both show that the trajectory of possible combinations of pressure and elevation at which the device is in static equilibrium takes the shape of an S. This means that statically the device can have three different draughts, and correspondingly three different bag shapes, for the same pressure. The behaviour in waves depends on where the mean pressure-elevation condition is on the static trajectory. The captured power is highest for a mean condition on the middle section. PMID:28484330
NASA Astrophysics Data System (ADS)
Jablonska, J.; Kozubkova, M.
2017-08-01
Static and dynamic characteristics of flow in technical practice are very important and serious problem and can be solved by experimental measurement or mathematical modeling. Unsteady flow presents time changes of the flow and water hammer can be an example of this phenomenon. Water hammer is caused by rapid changes in the water flow by means the closure or opening of the control valve. The authors deal with by hydraulic hammer at the multiphase flow (water and air), its one-dimensional modeling (Matlab SimHydraulics) and modeling with the use of the finite volume method (Ansys Fluent) in article. The circuit elements are defined by static and dynamic characteristics. The results are verified with measurements. The article evaluates different approaches, their advantages, disadvantages and specifics in solving of water hammer.
Wave energy absorption by a submerged air bag connected to a rigid float
NASA Astrophysics Data System (ADS)
Kurniawan, A.; Chaplin, J. R.; Hann, M. R.; Greaves, D. M.; Farley, F. J. M.
2017-04-01
A new wave energy device features a submerged ballasted air bag connected at the top to a rigid float. Under wave action, the bag expands and contracts, creating a reciprocating air flow through a turbine between the bag and another volume housed within the float. Laboratory measurements are generally in good agreement with numerical predictions. Both show that the trajectory of possible combinations of pressure and elevation at which the device is in static equilibrium takes the shape of an S. This means that statically the device can have three different draughts, and correspondingly three different bag shapes, for the same pressure. The behaviour in waves depends on where the mean pressure-elevation condition is on the static trajectory. The captured power is highest for a mean condition on the middle section.
Hart, Roger C; Herring, G C; Balla, R Jeffrey
2007-06-15
Nonintrusive, off-body flow barometry in Mach 2 airflow has been demonstrated in a large-scale supersonic wind tunnel using seedless laser-induced thermal acoustics (LITA). The static pressure of the gas flow is determined with a novel differential absorption measurement of the ultrasonic sound produced by the LITA pump process. Simultaneously, the streamwise velocity and static gas temperature of the same spatially resolved sample volume were measured with this nonresonant time-averaged LITA technique. Mach number, temperature, and pressure have 0.2%, 0.4%, and 4% rms agreement, respectively, in comparison with known free-stream conditions.
1991-07-31
memory banks Up to 1.25MByte SRAM 5 planes of 2048 x 1024 pixels Programmable video parameters max 720 x 512 pixels Sixteen colors TTL RGBI standard...bit I/O extension bus (VLXbus) Up to 2048 KByte 0-wait state static RAM BTT (Built-In-Test) PAL selectable dual ported VMEbus address Two RS-232/422...16, 25, or 33 MHz) A16/24:D08/16 VMEbus interface 8/16-bit I/O Extension bus (VLXbus) Up to 2048 KByte 32-bit wide static RAM -- 0-wait state at 16
Acoustic structure and propagation in highly porous, layered, fibrous materials
NASA Technical Reports Server (NTRS)
Lambert, R. F.; Tesar, J. S.
1984-01-01
The acoustic structure and propagation of sound in highly porous, layered, fine fiber materials is examined. Of particular interest is the utilization of the Kozeny number for determining the static flow resistance and the static structure factor based on flow permeability measurements. In this formulation the Kozeny number is a numerical constant independent of volume porosity at high porosities. The other essential parameters are then evaluated employing techniques developed earlier for open cell foams. The attenuation and progressive phase characteristics in bulk samples are measured and compared with predicted values. The agreements on the whole are very satisfactory.
NASA Technical Reports Server (NTRS)
Hart, Roger C.; Herring, Gregory C.; Balla, Robert J.
2007-01-01
Nonintrusive, off-body flow barometry in Mach-2 airflow has been demonstrated in a large-scale supersonic wind tunnel using seedless laser-induced thermal acoustics (LITA). The static pressure of the gas flow is determined with a novel differential absorption measurement of the ultrasonic sound produced by the LITA pump process. Simultaneously, stream-wise velocity and static gas temperature of the same spatially-resolved sample volume were measured with this nonresonant time-averaged LITA technique. Mach number, temperature and pressure have 0.2%, 0.4%, and 4% rms agreement, respectively, in comparison with known free-stream conditions.
Poroelastic metamaterials with negative effective static compressibility
NASA Astrophysics Data System (ADS)
Qu, Jingyuan; Kadic, Muamer; Wegener, Martin
2017-04-01
We suggest a three-dimensional metamaterial structure exhibiting an isotropic expansion in response to an increased hydrostatic pressure imposed by a surrounding gas or liquid. We show that this behavior corresponds to a negative absolute (rather than only differential) effective compressibility under truly static and stable conditions. The poroelastic metamaterial is composed of only a single ordinary constituent solid. By detailed numerical parameter studies, we find that a pressure increase of merely one bar can lead to a relative increase in the effective volume exceeding one percent for geometrical structure parameters that should be accessible to fabrication by 3D printing.
Hansen, Cristi V.; Lanning-Rush, Jennifer L.; Ziegler, Andrew C.
2013-01-01
Beginning in the 1940s, the Wichita well field was developed in the Equus Beds aquifer in southwestern Harvey County and northwestern Sedgwick County to supply water to the city of Wichita. The decline of water levels in the aquifer was noted soon after the development of the Wichita well field began. Development of irrigation wells began in the 1960s. City and agricultural withdrawals led to substantial water-level declines. Water-level declines enhanced movement of brines from past oil and gas activities near Burrton, Kansas and enhanced movement of natural saline water from the Arkansas River into the well field area. Large chloride concentrations may limit use or require the treatment of water from the well field for irrigation or public supply. In 1993, the city of Wichita adopted the Integrated Local Water Supply Program (ILWSP) to ensure an adequate water supply for the city through 2050 and as part of its effort to effectively manage the part of the Equus Beds aquifer it uses. ILWSP uses several strategies to do this including the Equus Beds Aquifer Storage and Recovery (ASR) project. The purpose of the ASR project is to store water in the aquifer for later recovery and to help protect the aquifer from encroachment of a known oilfield brine plume near Burrton and saline water from the Arkansas River. As part of Wichita’s ASR permits, Wichita is prohibited from artificially recharging water into the aquifer in a Basin Storage area (BSA) grid cell if water levels in that cell are above the January 1940 water levels or are less than 10 feet below land surface. The map previously used for this purpose did not provide an accurate representation of the shallow water table. The revised predevelopment water-level altitude map of the shallow part of the aquifer is presented in this report. The city of Wichita’s ASR permits specify that the January 1993 water-level altitudes will be used as a lower baseline for regulating the withdrawal of artificial rechage credits from the Equus Beds aquifer by the city of Wichita. The 1993 water levels correspond to the lowest recorded levels and largest storage declines since 1940. Revised and new water-level maps of shallow and deep layers were developed to better represent the general condition of the aquifer. Only static water levels were used to better represent the general condition of the aquifer and comply with Wichita’s ASR permits. To ensure adequate data density, the January 1993 period was expanded to October 1992 through February 1993. Static 1993 water levels from the deep aquifer layer of the Equus Beds aquifer possibly could be used as the lower baseline for regulatory purposes. Previously, maps of water-level changes used to estimate the storage-volume changes included a combination of static (unaffected by pumping or nearby pumping) and stressed (affected by pumping or nearby pumping) water levels from wells. Some of these wells were open to the shallow aquifer layer and some were open to the deep aquifer layer of the Equus Beds aquifer. In this report, only static water levels in the shallow aquifer layer were used to determine storage-volume changes. The effects on average water-level and storage-volume change from the use of mixed, stressed water levels and a specific yield of 0.20 were compared to the use of static water levels in the shallow aquifer and a specific yield of 0.15. This comparison indicates that the change in specific yield causes storage-volume changes to decrease about 25 percent, whereas the use of static water levels in the shallow aquifer layer causes an increase of less than 4 percent. Use of a specific yield of 0.15 will result in substantial decreases in the amount of storage-volume change compared to those reported previously that were calculated using a specific yield of 0.20. Based on these revised water-level maps and computations, the overall decline and change in storage from predevelopment to 1993 represented a loss in storage of about 6 percent (-202,000 acre-feet) of the overall storage volume within the newly defined study area.
Parametric study of intersatellite CO2 laser data links
NASA Astrophysics Data System (ADS)
Bonek, E.; Lutz, H.
The performance capability of current CO2 laser communication tecnology for intersatellite data links is evaluated. The link parameters, such as the distance, bit rate, ac signal-to-noise ratio, are related to the masses and the prime power requirements of satellite laser terminals using variables like the telescope (antenna) aperture diameter and the transmitted laser power. It is found that high data rates could be readily transmitted with telescopes of the order of only 10 cm in diameter, with the complte laser data terminals weighing between 25 kg and 70 kg and consuming prime power in the 90-300 W range. In addition, these terminals would require only about 0.1 cu m or less of volume and a very low movable antenna mass, which would alleviate constraints on satellite attitude control units in remote sensing missions.
NASA Astrophysics Data System (ADS)
Zhang, Chi; Shen, Wenfei; Zhang, Liwen; Xia, Yingnan; Li, Ruiqin
2017-04-01
A gamma prime ( γ') precipitation ( 35% in volume)-hardened powder metallurgy (P/M) superalloy FGH96 was welded using inertia friction welding (IFW). The microstructure and γ' distributions in the joints in two conditions, hot isostatic pressed state and solution-treated and aged state, were characterized. The recrystallization of grains, the dissolution and re-precipitation of γ' in the joints were discussed in terms of the temperature evolutions which were calculated by finite element model analysis. Regardless of the initial states, fully recrystallized fine grain structure formed at welded zone. Meanwhile, very fine γ' precipitations were re-precipitated at the welded zone. These recrystallized grain structure and fine re-precipitated γ' resulted in increasing hardness of IFW joint while making the hardness dependent on the microstructure and γ' precipitation.
Development of PRIME for irradiation performance analysis of U-Mo/Al dispersion fuel
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jeong, Gwan Yoon; Kim, Yeon Soo; Jeong, Yong Jin
A prediction code for the thermo-mechanical performance of research reactor fuel (PRIME) has been developed with the implementation of developed models to analyze the irradiation behavior of U-Mo dispersion fuel. The code is capable of predicting the two-dimensional thermal and mechanical performance of U-Mo dispersion fuel during irradiation. A finite element method was employed to solve the governing equations for thermal and mechanical equilibria. Temperature-and burnup-dependent material properties of the fuel meat constituents and cladding were used. The numerical solution schemes in PRIME were verified by benchmarking solutions obtained using a commercial finite element analysis program (ABAQUS).The code was validatedmore » using irradiation data from RERTR, HAMP-1, and E-FUTURE tests. The measured irradiation data used in the validation were IL thickness, volume fractions of fuel meat constituents for the thermal analysis, and profiles of the plate thickness changes and fuel meat swelling for the mechanical analysis. The prediction results were in good agreement with the measurement data for both thermal and mechanical analyses, confirming the validity of the code. (c) 2018 Elsevier B.V. All rights reserved.« less
NASA Astrophysics Data System (ADS)
Rahmouni, Lyes; Mitharwal, Rajendra; Andriulli, Francesco P.
2017-11-01
This work presents two new volume integral equations for the Electroencephalography (EEG) forward problem which, differently from the standard integral approaches in the domain, can handle heterogeneities and anisotropies of the head/brain conductivity profiles. The new formulations translate to the quasi-static regime some volume integral equation strategies that have been successfully applied to high frequency electromagnetic scattering problems. This has been obtained by extending, to the volume case, the two classical surface integral formulations used in EEG imaging and by introducing an extra surface equation, in addition to the volume ones, to properly handle boundary conditions. Numerical results corroborate theoretical treatments, showing the competitiveness of our new schemes over existing techniques and qualifying them as a valid alternative to differential equation based methods.
Modeling Density Variation in the Thermosphere
2011-04-29
static electromagnetic fields as follows: when a volume of the ionosphere is bounded on the sides by an equipotential surface and on the bottom by the...generation of electromagnetic energy along that geomagnetic-field line. An Equipotential -Boundary Poynting-Flux (EBPF) theorem was presented for quasi
Dynamic shear jamming in granular suspensions
NASA Astrophysics Data System (ADS)
Peters, Ivo; Majumdar, Sayantan; Jaeger, Heinrich
2014-11-01
Jamming by shear allows a frictional granular packing to transition from an unjammed state into a jammed state while keeping the system volume and average packing fraction constant. Shear jamming of dry granular media can occur quasi-statically, but boundaries are crucial to confine the material. We perform experiments in aqueous starch suspension where we apply shear using a rheometer with a large volume (400 ml) cylindrical Couette cell. In our suspensions the packing fraction is sufficiently low that quasi-static deformation does not induce a shear jammed state. Applying a shock-like deformation however, will turn the suspension into a jammed solid. A fully jammed state is reached within tens of microseconds, and can be sustained for at least several seconds. High speed imaging of the initial process reveals a jamming front propagating radially outward through the suspension, while the suspension near the outer boundary remains quiescent. This indicates that granular suspensions can be shear jammed without the need of confining solid boundaries. Instead, confinement is most likely provided by the dynamics in the front region.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
A geotechnical study has been completed in H-Area for the In-Tank Precipitation Facility (ITP) and the balance of the H-Area Tank Farm (HTF) at the Savannah River Site (SRS) in South Carolina. The study consisted of subsurface field exploration, field and laboratory testing, and engineering analyses. The purpose of these investigations is to evaluate the overall stability of the H-Area tanks under static and dynamic conditions. The objectives of the study are to define the site-specific geological conditions at ITP and HTF, obtain engineering properties for the assessment of the stability of the native soils and embankment under static andmore » dynamic loads (i.e., slope stability, liquefaction potential, and potential settlements), and derive properties for soil-structure interaction studies. This document (Volume 5) contains the laboratory test results for the In-Tank Precipitation Facility (ITP) and H-Tank Farm (HTF) Geotechnical Report.« less
Lung vagal afferent activity in rats with bleomycin-induced lung fibrosis.
Schelegle, E S; Walby, W F; Mansoor, J K; Chen, A T
2001-05-01
Bleomycin treatment in rats results in pulmonary fibrosis that is characterized by a rapid shallow breathing pattern, a decrease in quasi-static lung compliance and a blunting of the Hering-Breuer Inflation Reflex. We examined the impulse activity of pulmonary vagal afferents in anesthetized, mechanically ventilated rats with bleomycin-induced lung fibrosis during the ventilator cycle and static lung inflations/deflations and following the injection of capsaicin into the right atrium. Bleomycin enhanced volume sensitivity of slowly adapting stretch receptors (SARs), while it blunted the sensitivity of these receptors to increasing transpulmonary pressure. Bleomycin treatment increased the inspiratory activity, while it decreased the expiratory activity of rapidly adapting stretch receptors (RARs). Pulmonary C-fiber impulse activity did not appear to be affected by bleomycin treatment. We conclude that the fibrosis-related shift in discharge profile and enhanced volume sensitivity of SARs combined with the increased inspiratory activity of RARs contributes to the observed rapid shallow breathing of bleomycin-induced lung fibrosis.
SEM Analysis Techniques for LSI Microcircuits. Volume 2
1980-08-01
4~, 1 v’ ’ RADC-TR80-250, Vol 11 (of two), Final Technical -Report, Augut1980 SEM, ANALYSIS TECHNIQUES, FOR LSI MICROCIRCUITS: ’Martin...Bit Static ’RAM.. Volume II - 1024 Bit Stat’i RAM, 4096 Bit Dynamic RAM (SiGATE WOS,)., 4096 Bit -Dynamic RAM ( 1 2 L Bipolar)., ,Summary. RADC-TR-80-250...States, ithout.irst obtani an export nse, is a violation t Internatio 1 Tr ffic in A . eguiations. Such violation is subject o penalty of to 2 years impr
NASA Astrophysics Data System (ADS)
Stemkens, Bjorn; Glitzner, Markus; Kontaxis, Charis; de Senneville, Baudouin Denis; Prins, Fieke M.; Crijns, Sjoerd P. M.; Kerkmeijer, Linda G. W.; Lagendijk, Jan J. W.; van den Berg, Cornelis A. T.; Tijssen, Rob H. N.
2017-09-01
Stereotactic body radiation therapy (SBRT) has shown great promise in increasing local control rates for renal-cell carcinoma (RCC). Characterized by steep dose gradients and high fraction doses, these hypo-fractionated treatments are, however, prone to dosimetric errors as a result of variations in intra-fraction respiratory-induced motion, such as drifts and amplitude alterations. This may lead to significant variations in the deposited dose. This study aims to develop a method for calculating the accumulated dose for MRI-guided SBRT of RCC in the presence of intra-fraction respiratory variations and determine the effect of such variations on the deposited dose. For this, RCC SBRT treatments were simulated while the underlying anatomy was moving, based on motion information from three motion models with increasing complexity: (1) STATIC, in which static anatomy was assumed, (2) AVG-RESP, in which 4D-MRI phase-volumes were time-weighted, and (3) PCA, a method that generates 3D volumes with sufficient spatio-temporal resolution to capture respiration and intra-fraction variations. Five RCC patients and two volunteers were included and treatments delivery was simulated, using motion derived from subject-specific MR imaging. Motion was most accurately estimated using the PCA method with root-mean-squared errors of 2.7, 2.4, 1.0 mm for STATIC, AVG-RESP and PCA, respectively. The heterogeneous patient group demonstrated relatively large dosimetric differences between the STATIC and AVG-RESP, and the PCA reconstructed dose maps, with hotspots up to 40% of the D99 and an underdosed GTV in three out of the five patients. This shows the potential importance of including intra-fraction motion variations in dose calculations.
Threat Recognition and Response. Volume 2,
1986-08-01
strongly anti-communist caretaker regime. Tunku Abdul Rahman, the Malay conservative anti-colonialist leader of the Alliance Party was invited to pay an...May 1961 Tunku Abdul Rahman, the new Prime Minister of Malaya, proposed a ’closer understanding’ with Britain and the peoples of Singapore, North...dispute. Senator Robert Kennedy met Sukarno in Tokyo in mid-January 1964, and later flew to Kuala Lumpur for discussions with Tunku Abdul Rahman. A
Four test-demonstrations of hardwood log grades in the Northeast
George E. Doverspike; Harry W., Jr. Camp
1951-01-01
Farmers don't sell prime steers for the same price per pound as canner cows. Lumber dealers don't sell top-quality boards for the same price as Number 3 Common. If you are a timber owner, why should you sell hardwood trees or logs without considering their quality? Logs that yield a high proportion of their volume in the better grades of lumber are certainly...
The "benefits" of the mini-extracorporeal circulation in the minimal invasive cardiac surgery era.
Baikoussis, Nikolaos G; Papakonstantinou, Nikolaos A; Apostolakis, Efstratios
2014-06-01
Mini-extracorporeal circulation (MECC) constitutes a novel miniaturized cardiopulmonary bypass (CPB) circuit, heparin-coated and primed with aprotinin. Its membrane oxygenation is similar to conventional cardio-pulmonary bypass (CCPB), but it is a completely closed-volume system due to the lack of the venous reservoir which has been removed. In a mini circuit, the reservoir is the patient himself. Consequently, air entering the venous cannula is avoided. Nevertheless, the capabilities of MECC have been expanded either by the inclusion of a suction device that is only activated on direct contact with liquid in some circuits or by postoperative autotransfusion of the wrecked erythrocytes by a separate suction device with a cell-saver. Although the tubing diameter is similar between the two systems, the tubing length of the MECC is around half that of the CCPB, resulting in the restriction of priming volume. As a consequence, a higher hematocrit thus a limited need for perioperative blood transfusion is achieved due to less hemodilution. In addition, the inflammatory response is also diminished as a result of less artificial surface area interacting with blood. Finally, a lower dose of heparin is required prior to MECC than prior to CCPB. Copyright © 2014 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.
Thiara, A S; Eggereide, V; Pedersen, T; Lindberg, H; Fiane, A E
2010-07-01
The neonate cardiopulmonary bypass (CPB) circuit, including a KIDS D100 oxygenator (The Sorin Group, Mirandola, Italy) and a D130 arterial filter (The Sorin Group), was evaluated in vitro with respect to the removal of free micro gas bubbles. No gas bubbles > 40microm were measured after the arterial filter D130 upon manual introduction of 10 ml of air into the venous line or during the use of vacuum-assisted venous drainage (VAVD). The D130 arterial filter removed 88 % of gas bubbles < 40 microm during manual introduction of air into the venous line; however, only 50 % of gas bubbles < 40 microm were removed during the use of VAVD. The same CPB circuit was evaluated in vivo to compare with another CPB circuit, including a D901 oxygenator (The Sorin Group) and arterial filter D736 (The Sorin Group), in 155 neonates weighing < or =5 kg. The D100 circuit required significantly less priming volume than the D901 circuit. Postoperative haemoglobin was significantly higher, artificial ventilation time was significantly shorter and postoperative bleeding was significantly less in the D100 group. This neonate CPB circuit effectively removed the gas bubbles and required up to 37% less priming volume and, thus, decreased the need for blood transfusion.
Impaired recognition of body expressions in the behavioral variant of frontotemporal dementia.
Van den Stock, Jan; De Winter, François-Laurent; de Gelder, Beatrice; Rangarajan, Janaki Raman; Cypers, Gert; Maes, Frederik; Sunaert, Stefan; Goffin, Karolien; Vandenberghe, Rik; Vandenbulcke, Mathieu
2015-08-01
Progressive deterioration of social cognition and emotion processing are core symptoms of the behavioral variant of frontotemporal dementia (bvFTD). Here we investigate whether bvFTD is also associated with impaired recognition of static (Experiment 1) and dynamic (Experiment 2) bodily expressions. In addition, we compared body expression processing with processing of static (Experiment 3) and dynamic (Experiment 4) facial expressions, as well as with face identity processing (Experiment 5). The results reveal that bvFTD is associated with impaired recognition of static and dynamic bodily and facial expressions, while identity processing was intact. No differential impairments were observed regarding motion (static vs. dynamic) or category (body vs. face). Within the bvFTD group, we observed a significant partial correlation between body and face expression recognition, when controlling for performance on the identity task. Voxel-Based Morphometry (VBM) analysis revealed that body emotion recognition was positively associated with gray matter volume in a region of the inferior frontal gyrus (pars orbitalis/triangularis). The results are in line with a supramodal emotion recognition deficit in bvFTD. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Pool, Kirby V.
1989-01-01
This volume summarizes the analysis used to assess the structural life of the Space Shuttle Main Engine (SSME) High Pressure Fuel Turbo-Pump (HPFTP) Third Stage Impeller. This analysis was performed in three phases, all using the DIAL finite element code. The first phase was a static stress analysis to determine the mean (non-varying) stress and static margin of safety for the part. The loads involved were steady state pressure and centrifugal force due to spinning. The second phase of the analysis was a modal survey to determine the vibrational modes and natural frequencies of the impeller. The third phase was a dynamic response analysis to determine the alternating component of the stress due to time varying pressure impulses at the outlet (diffuser) side of the impeller. The results of the three phases of the analysis show that the Third Stage Impeller operates very near the upper limits of its capability at full power level (FPL) loading. The static loading alone creates stresses in some areas of the shroud which exceed the yield point of the material. Additional cyclic loading due to the dynamic force could lead to a significant reduction in the life of this part. The cyclic stresses determined in the dynamic response phase of this study are based on an assumption regarding the magnitude of the forcing function.
Treatment of extensive scalp lesions with segmental intensity-modulated photon therapy.
Bedford, James L; Childs, Peter J; Hansen, Vibeke Nordmark; Warrington, Alan P; Mendes, Ruheena L; Glees, John P
2005-08-01
To compare static electron therapy, electron arc therapy, and photon intensity-modulated radiation therapy (IMRT) for treatment of extensive scalp lesions and to examine the dosimetric accuracy of the techniques. A retrospective treatment-planning study was performed to evaluate the relative merits of static electron fields, arcing electron fields, and five-field photon IMRT. Thermoluminescent dosimeters (TLD) were used to verify the accuracy of the techniques. The required thickness of bolus was investigated, and an anthropomorphic phantom was also used to examine the effects of air gaps between the wax bolus used for the IMRT technique and the patient's scalp. Neither static nor arcing electron techniques were able to provide a reliable coverage of the planning target volume (PTV), owing to obliquity of the fields in relation to the scalp. The IMRT technique considerably improved PTV dose uniformity, though it irradiated a larger volume of brain. Either 0.5 cm or 1.0 cm of wax bolus was found to be suitable. Air gaps of up to 1 cm between the bolus and the patient's scalp were correctly handled by the treatment-planning system and had negligible influence on the dose to the scalp. Photon IMRT provides a feasible alternative to electron techniques for treatment of large scalp lesions, resulting in improved homogeneity of dose to the PTV but with a moderate increase in dose to the brain.
Schlanstein, Peter C; Borchardt, Ralf; Mager, Ilona; Schmitz-Rode, Thomas; Steinseifer, Ulrich; Arens, Jutta
2014-01-01
Oxygenators have been used in neonatal extracorporeal membrane oxygenation (ECMO) since the 1970s. The need to develop a more effective oxygenator for this patient cohort exists due to their size and blood volume limitations. This study sought to validate the next design iteration of a novel oxygenator for neonatal ECMO with an integrated pulsatile displacement pump, thereby superseding an additional blood pump. Pulsating blood flow within the oxygenator is generated by synchronized active air flow expansion and contraction of integrated silicone pump tubes and hose pinching valves located at the oxygenator inlet and outlet. The current redesign improved upon previous prototypes by optimizing silicone pump tube distribution within the oxygenator fiber bundle; introduction of an oval shaped inner fiber bundle core, and housing; and a higher fiber packing density, all of which in combination reduced the priming volume by about 50% (50 to 27 mL and 41 to 20 mL, respectively). Gas exchange efficiency was tested for two new oxygenators manufactured with different fiber materials: one with coating and one with smaller pore size, both capable of long-term use (OXYPLUS® and CELGARD®). Results demonstrated that the oxygen transfer for both oxygenators was 5.3-24.7 mlO2/min for blood flow ranges of 100-500 mlblood/min. Carbon dioxide transfer for both oxygenators was 3.7-26.3 mlCO2/min for the same blood flow range. These preliminary results validated the oxygenator redesign by demonstrating an increase in packing density and thus in gas transfer, an increase in pumping capacity and a reduction in priming volume.
Weber, Damien C; Bogner, Joachim; Verwey, Jorn; Georg, Dietmar; Dieckmann, Karin; Escudé, Lluis; Caro, Monica; Pötter, Richard; Goitein, Gudrun; Lomax, Antony J; Miralbell, Raymond
2005-10-01
A comparative treatment planning study was undertaken between proton and photon therapy in uveal melanoma to assess the potential benefits and limitations of these treatment modalities. A fixed proton horizontal beam (OPTIS) and intensity-modulated spot-scanning proton therapy (IMPT), with multiple noncoplanar beam arrangements, was compared with linear accelerator-based stereotactic radiotherapy (SRT), using a static and a dynamic micromultileaf collimator and intensity-modulated RT (IMRS). A planning CT scan was performed on a brain metastasis patient, with a 3-mm acquisition slice spacing and the patient looking at a luminous spot with the eyes in three different positions (neutral and 25 degrees right and left). Four different gross tumor volumes were defined for each treatment technique. These target scenarios represented different locations (involving vs. not involving the macula and temporal vs. nasal) and volumes (10 x 6 mm vs. 16 x 10 mm) to challenge the proton and photon treatment techniques. The planning target volume was defined as the gross tumor volume plus 2 mm laterally and 3 mm craniocaudally for both modalities. A dose homogeneity of 95-99% of the planning target volume was used as the "goal" for all techniques. The dose constraint (maximum) for the organs at risk (OARs) for both the proton and the SRT photon plans was 27.5, 22.5, 20, and 9 CGE-Gy for the optic apparatus, retina, lacrimal gland, and lens, respectively. The dose to the planning target volume was 50 CGE-Gy in 10 CGE-Gy daily fractions. The plans for proton and photon therapy were computed using the Paul Scherrer Institute and BrainSCAN, version 5.2 (BrainLAB, Heimstetten, Germany) treatment planning systems, respectively. Tumor and OARs dose-volume histograms were calculated. The results were analyzed using the dose-volume histogram parameters, conformity index (CI(95%)), and inhomogeneity coefficient. Target coverage of all simulated uveal melanomas was equally conformal with the photon and proton modalities. The median CI(95%) value was 1.74, 1.86, and 1.83 for the static, dynamic, and IMSRT plans, respectively. With proton planning, the median CI(95%) was 1.88 for OPTIS and substantially improved with IMPT in some tumor cases (median CI(95%), 1.29). The tumor dose homogeneity in the proton plans was, however, always better than with SRT photon planning (median inhomogeneity coefficient 0.1 and 0.15 vs. 0.46, 0.41, and 0.23 for the OPTIS and IMPT vs. the static, dynamic, and IMSRT plans, respectively). Compared with the photon plans, the use of protons did not lead to a substantial reduction in the homolateral OAR total integral dose in the low- to high-dose level, except for the lacrimal gland. The median maximal dose and dose at the 10% volume with the static, dynamic, and IMSRT plans was 33-30.8, 31.8-28, and 35.8-49 Gy, respectively, for the lacrimal gland, a critical organ. For protons, only the OPTIS plans were better, with a median maximal dose and dose at the 10% volume using OPTIS and IMPT of 19.2 and 8.8 and 25.6 and 23.6 CGE, respectively. The contralateral OARs were completely spared with the proton plans, but the median dose delivered to these structures was 1.2 Gy (range, 0-6.3 Gy) with the SRT photon plans. These results suggest that the use of SRT photon techniques, compared with protons, can result in similar levels of dose conformation. IMPT did not increase the degree of conformality for this small tumor. Tumor dose inhomogeneity was, however, always increased with photon planning. Except for the lacrimal gland, the use of protons, with or without intensity modulation, did not increase homolateral OAR dose sparing. The dose to all the contralateral OARs was, however, completely eliminated with proton planning.
Effects of combustibles on internal quasi-static loads
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sandoval, N.R.; Hokanson, J.C.; Esparza, E.D.
1984-08-01
The phenomenon of quasi-static pressure enhancement produced when combustible materials are placed near HE sources has been recently discovered. The effects of placing solid and liquid combustible materials near detonating explosives on internal blast loading was measured during tests conducted in a one-eighth scale model of a containment structure. In many cases, dramatic increases in gas pressures resulted. Principal conclusions of this study are: combustible materials near explosives can markedly increase gas pressures in enclosed structures; there is a lack of data on HE-combustible combinations; quasi-static loading calculations should include estimates of contributions from the burning of combustible materials whenevermore » such materials are expected to be in intimate contact with HE sources; and effects of combustibles should be investigated further to determine methods for prediction. Variations in charge to combustible mass, charge type, structure volume, degree of venting and degree of contact between HE and combustible sbould be studied.« less
Magma degassing triggered by static decompression at Kīlauea Volcano, Hawai‘i
Poland, Michael P.; Jeff, Sutton A.; Gerlach, Terrence M.
2009-01-01
During mid-June 2007, the summit of Kīlauea Volcano, Hawai‘i, deflated rapidly as magma drained from the subsurface to feed an east rift zone intrusion and eruption. Coincident with the deflation, summit SO2 emission rates rose by a factor of four before decaying to background levels over several weeks. We propose that SO2 release was triggered by static decompression caused by magma withdrawal from Kīlauea's shallow summit reservoir. Models of the deflation suggest a pressure drop of 0.5–3 MPa, which is sufficient to trigger exsolution of the observed excess SO2 from a relatively small volume of magma at the modeled source depth beneath Kīlauea's summit. Static decompression may also explain other episodes of deflation accompanied by heightened gas emission, including the precursory phases of Kīlauea's 2008 summit eruption. Hazards associated with unexpected volcanic gas emission argue for increased awareness of magma reservoir pressure fluctuations.
Analysis of laboratory compaction methods of roller compacted concrete
NASA Astrophysics Data System (ADS)
Trtík, Tomáš; Chylík, Roman; Bílý, Petr; Fládr, Josef
2017-09-01
Roller-Compacted Concrete (RCC) is an ordinary concrete poured and compacted with machines typically used for laying of asphalt road layers. One of the problems connected with this technology is preparation of representative samples in the laboratory. The aim of this work was to analyse two methods of preparation of RCC laboratory samples with bulk density as the comparative parameter. The first method used dynamic compaction by pneumatic hammer. The second method of compaction had a static character. The specimens were loaded by precisely defined force in laboratory loading machine to create the same conditions as during static rolling (in the Czech Republic, only static rolling is commonly used). Bulk densities obtained by the two compaction methods were compared with core drills extracted from real RCC structure. The results have shown that the samples produced by pneumatic hammer tend to overestimate the bulk density of the material. For both compaction methods, immediate bearing index test was performed to verify the quality of compaction. A fundamental difference between static and dynamic compaction was identified. In static compaction, initial resistance to penetration of the mandrel was higher, after exceeding certain limit the resistance was constant. This means that the samples were well compacted just on the surface. Specimens made by pneumatic hammer actively resisted throughout the test, the whole volume was uniformly compacted.
LEWICE3D/GlennHT Particle Analysis of the Honeywell Al502 Low Pressure Compressor
NASA Technical Reports Server (NTRS)
Bidwell, Colin S.; Rigby, David L.
2015-01-01
A flow and ice particle trajectory analysis was performed for the booster of the Honeywell AL502 engine. The analysis focused on two closely related conditions one of which produced a rollback and another which did not rollback during testing in the Propulsion Systems Lab at NASA Glenn Research Center. The flow analysis was generated using the NASA Glenn GlennHT flow solver and the particle analysis was generated using the NASA Glenn LEWICE3D v3.56 ice accretion software. The flow and particle analysis used a 3D steady flow, mixing plane approach to model the transport of flow and particles through the engine. The inflow conditions for the rollback case were: airspeed, 145 ms; static pressure, 33,373 Pa; static temperature, 253.3 K. The inflow conditions for the non-roll-back case were: airspeed, 153 ms; static pressure, 34,252 Pa; static temperature, 260.1 K. Both cases were subjected to an ice particle cloud with a median volume diameter of 24 microns, an ice water content of 2.0 gm3 and a relative humidity of 100 percent. The most significant difference between the rollback and non-rollback conditions was the inflow static temperature which was 6.8 K higher for the non-rollback case.
Comparison of point intercept and image analysis for monitoring rangeland transects
USDA-ARS?s Scientific Manuscript database
Amidst increasing workloads and static or declining budgets, both public and private land management agencies face the need to adapt resource-monitoring techniques or risk falling behind on resource monitoring volume and quality with old techniques. Image analysis of nadir plot images, acquired with...
NASA Technical Reports Server (NTRS)
Violett, Rebeca S.
1989-01-01
The analysis performed on the Main Injector LOX Inlet Assembly located on the Space Shuttle Main Engine is summarized. An ANSYS finite element model of the inlet assemably was built and executed. Static stress analysis was also performed.
Accuracy of the NDI Wave Speech Research System
ERIC Educational Resources Information Center
Berry, Jeffrey J.
2011-01-01
Purpose: This work provides a quantitative assessment of the positional tracking accuracy of the NDI Wave Speech Research System. Method: Three experiments were completed: (a) static rigid-body tracking across different locations in the electromagnetic field volume, (b) dynamic rigid-body tracking across different locations within the…
DOT National Transportation Integrated Search
1998-05-01
In Order to determine equivalent static pressures for fatigue loads on cantilevered highway support structures a : cantilevered Variable Message Sign(VMS) located along Interstate westbound at mile marker 48.5 in northern : New Jersey was continuousl...
DOT National Transportation Integrated Search
1998-04-01
In Order to determine equivalent static pressures for fatigue loads on cantilevered highway support structures a : cantilevered Variable Message Sign(VMS) located along Interstate westbound at mile marker 48.5 in northern : New Jersey was continuousl...
ERIC Educational Resources Information Center
Bureau of Naval Personnel, Washington, DC.
The second of three volumes of a mathematics training course for Navy personnel, this document contains material primarily found at the college level. Beginning with logarithms and trigonometry, the text moves into vectors and static equilibrium (physics). Coordinate geometry, conic sections, and the tangents, normals, and slopes of curves follow.…
NASA Technical Reports Server (NTRS)
Alexander, S. S.; Hodgdon, R. B.; Waite, W. A.
1979-01-01
Experimental composite membranes were synthesized on a lab scale consisting of a thin layer of anion permselective resin supported by and bonded to a porous physically strong and conductive substrate film. These showed good selectivity and also substantially lower electrical resistivities than the homogenous candidate membranes optimized in the previous contract. A wide range of resin porosities were examined for three candidate membrane systems, CDIL, CP4L, and A3L to identify the formulation giving the best overall redox cell performance. Candidate anion membranes showed large increases in resistivity after a short time of immersion in concentrated FeCl/HCl solution. Largely on the basis of resistance stability the CDIL formulation was selected as prime candidate and about thirty-five membranes (one foot square) were produced for experimental static and dynamic evaluation.
PIC simulation of compressive and rarefactive dust ion-acoustic solitary waves
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Zhong-Zheng; Zhang, Heng; Hong, Xue-Ren
The nonlinear propagations of dust ion-acoustic solitary waves in a collisionless four-component unmagnetized dusty plasma system containing nonextensive electrons, inertial negative ions, Maxwellian positive ions, and negatively charged static dust grains have been investigated by the particle-in-cell method. By comparing the simulation results with those obtained from the traditional reductive perturbation method, it is observed that the rarefactive KdV solitons propagate stably at a low amplitude, and when the amplitude is increased, the prime wave form evolves and then gradually breaks into several small amplitude solitary waves near the tail of soliton structure. The compressive KdV solitons propagate unstably andmore » oscillation arises near the tail of soliton structure. The finite amplitude rarefactive and compressive Gardner solitons seem to propagate stably.« less
NASA Astrophysics Data System (ADS)
Box, Paul W.
GIS and spatial analysis is suited mainly for static pictures of the landscape, but many of the processes that need exploring are dynamic in nature. Dynamic processes can be complex when put in a spatial context; our ability to study such processes will probably come with advances in understanding complex systems in general. Cellular automata and agent-based models are two prime candidates for exploring complex spatial systems, but are difficult to implement. Innovative tools that help build complex simulations will create larger user communities, who will probably find novel solutions for understanding complexity. A significant source for such innovations is likely to be from the collective efforts of hobbyists and part-time programmers, who have been dubbed ``garage-band scientists'' in the popular press.
[Modeling and analysis of volume conduction based on field-circuit coupling].
Tang, Zhide; Liu, Hailong; Xie, Xiaohui; Chen, Xiufa; Hou, Deming
2012-08-01
Numerical simulations of volume conduction can be used to analyze the process of energy transfer and explore the effects of some physical factors on energy transfer efficiency. We analyzed the 3D quasi-static electric field by the finite element method, and developed A 3D coupled field-circuit model of volume conduction basing on the coupling between the circuit and the electric field. The model includes a circuit simulation of the volume conduction to provide direct theoretical guidance for energy transfer optimization design. A field-circuit coupling model with circular cylinder electrodes was established on the platform of the software FEM3.5. Based on this, the effects of electrode cross section area, electrode distance and circuit parameters on the performance of volume conduction system were obtained, which provided a basis for optimized design of energy transfer efficiency.
Space Commercialization Trends and Consequences for the Workforce
NASA Astrophysics Data System (ADS)
Peeters, W.
2002-01-01
The major trend we are currently witnessing in space activities is an increasing level of commercialization. This trend is emphasized by: consolidation, mergers and forming strategic alliances. In USA, from the 20 major space companies in the 80's only 3 `prime' ones were left by 1997. A similar effect took place in Europe in the 90's, where at present only primarily 2 major space conglomerates are operating at prime contractor level. Such strategic alliances in the first place result in the creation of end-to-end capabilities, with larger internal R&D and broader access to technologies. Due to the bigger financial volume of such conglomerates there is also better access to new capital and sharing of risks. In a second step, we can at present observe the creation of transatlantic alliances to enter the worldwide market. These trends have a considerable effect on the workforce requirements in industry:
NASA Technical Reports Server (NTRS)
Rinsland, Curtis P.; Smith, Mary Ann H.; Devi, V. Malathy; Benner, D. Chris
1988-01-01
Air-broadened and N2-broadened halfwidth and pressure shift coefficients of 294 transitions in the nu4 and nu2 bands of C-12H4 have been measured from laboratory absorption spectra recorded at room temperature with the Fourier transform spectrometer in the McMath solar telescope facility of the National Solar Observatory. Total pressures of up to 551 Torr were employed with absorption paths of 5-150 cm, CH4 volume mixing ratios of 2.6 percent or less, and resolutions of 0.005 and 0.01/cm. A nonlinear least-squares spectral fitting technique has been utilized in the analysis of the twenty-five measured spectra. Lines up to J double-prime = 18 in the nu4 band and J double-prime = 15 in the nu2 band have been analyzed.
NASA Technical Reports Server (NTRS)
Janardan, B. A.; Brausch, J. F.; Price, A. O.
1984-01-01
Acoustic and diagnostic data that were obtained to determine the influence of selected geometric and aerodynamic flow variables of coannular nozzles with thermal acoustic shields are summarized in this comprehensive data report. A total of 136 static and simulated flight acoustic test points were conducted with 9 scale-model nozzles. Aerodynamic laser velocimeter measurements were made for four selected plumes. In addition, static pressure data in the chute base region of the suppressor configurations were obtained to assess the influence of the shield stream on the suppressor base drag.
NASA Technical Reports Server (NTRS)
Nelson, D. P.
1981-01-01
A graphical presentation of the aerodynamic data acquired during coannular nozzle performance wind tunnel tests is given. The graphical data consist of plots of nozzle gross thrust coefficient, fan nozzle discharge coefficient, and primary nozzle discharge coefficient. Normalized model component static pressure distributions are presented as a function of primary total pressure, fan total pressure, and ambient static pressure for selected operating conditions. In addition, the supersonic cruise configuration data include plots of nozzle efficiency and secondary-to-fan total pressure pumping characteristics. Supersonic and subsonic cruise data are given.
Water electrolysis system - H2 and O2 generation. [for spacecraft atmosphere revitalization
NASA Technical Reports Server (NTRS)
Schubert, F. H.; Lee, M. K.; Davenport, R. J.; Quattrone, P. D.
1978-01-01
An oxygen generation system design based on the static feed water electrolysis concept is described. The system is designed to generate 4.20 kg/d of oxygen to satisfy the metabolic needs of a three-person crew, to compensate for spacecraft leakage, and to provide the oxygen required by the electrochemical depolarized CO2 concentrator. The system has a fixed hardware weight of 75 kg, occupies a volume of 0.11 cu m, and requires only 1.1 kw of electrical power. The static feed electrolysis concept is discussed, and experimental data on the high-performance electrode are presented.
NASA Technical Reports Server (NTRS)
Orlik-Rueckermann, K. J.; Laberge, J. G.
1970-01-01
Static and dynamic pitching moment measurements were made on a family of constant volume elliptic cones about two fixed axes of oscillation in the NAE helium hypersonic wind tunnel at a Mach number of 11 and at Reynolds numbers based on model length of up to 14 million. Viscous effects on the stability derivatives were investigated by varying the Reynolds number for certain models by a factor as large as 10. The models investigated comprised a 7.75 deg circular cone, elliptic cones of axis ratios 3 and 6, and an elliptic cone with conical protuberances.
Motion-aware stroke volume quantification in 4D PC-MRI data of the human aorta.
Köhler, Benjamin; Preim, Uta; Grothoff, Matthias; Gutberlet, Matthias; Fischbach, Katharina; Preim, Bernhard
2016-02-01
4D PC-MRI enables the noninvasive measurement of time-resolved, three-dimensional blood flow data that allow quantification of the hemodynamics. Stroke volumes are essential to assess the cardiac function and evolution of different cardiovascular diseases. The calculation depends on the wall position and vessel orientation, which both change during the cardiac cycle due to the heart muscle contraction and the pumped blood. However, current systems for the quantitative 4D PC-MRI data analysis neglect the dynamic character and instead employ a static 3D vessel approximation. We quantify differences between stroke volumes in the aorta obtained with and without consideration of its dynamics. We describe a method that uses the approximating 3D segmentation to automatically initialize segmentation algorithms that require regions inside and outside the vessel for each temporal position. This enables the use of graph cuts to obtain 4D segmentations, extract vessel surfaces including centerlines for each temporal position and derive motion information. The stroke volume quantification is compared using measuring planes in static (3D) vessels, planes with fixed angulation inside dynamic vessels (this corresponds to the common 2D PC-MRI) and moving planes inside dynamic vessels. Seven datasets with different pathologies such as aneurysms and coarctations were evaluated in close collaboration with radiologists. Compared to the experts' manual stroke volume estimations, motion-aware quantification performs, on average, 1.57% better than calculations without motion consideration. The mean difference between stroke volumes obtained with the different methods is 7.82%. Automatically obtained 4D segmentations overlap by 85.75% with manually generated ones. Incorporating motion information in the stroke volume quantification yields slight but not statistically significant improvements. The presented method is feasible for the clinical routine, since computation times are low and essential parts run fully automatically. The 4D segmentations can be used for other algorithms as well. The simultaneous visualization and quantification may support the understanding and interpretation of cardiac blood flow.
Nonlinear dynamic characteristics of dielectric elastomer membranes
NASA Astrophysics Data System (ADS)
Fox, Jason W.; Goulbourne, Nakhiah C.
2008-03-01
The dynamic response of dielectric elastomer membranes subject to time-varying voltage inputs for various initial inflation states is investigated. These results provide new insight into the differences observed between quasi-static and dynamic actuation and presents a new challenge to modeling efforts. Dielectric elastomer membranes are a potentially enabling technology for soft robotics and biomedical devices such as implants and surgical tools. In this work, two key system parameters are varied: the chamber volume and the voltage signal offset. The chamber volume experiments reveal that increasing the size of the chamber onto which the membrane is clamped will increase the deformations as well as cause the membrane's resonance peaks to shift and change in number. For prestretched dielectric elastomer membranes at the smallest chamber volume, the maximum actuation displacement is 81 microns; while at the largest chamber volume, the maximum actuation displacement is 1431 microns. This corresponds to a 1767% increase in maximum pole displacement. In addition, actuating the membrane at the resonance frequencies provides hundreds of percent increase in strain compared to the quasi-static strain. Adding a voltage offset to the time-varying input signal causes the membrane to oscillate at two distinct frequencies rather than one and also presents a unique opportunity to increase the output displacement without electrically overloading the membrane. Experiments to capture the entire motion of the membrane reveal that classical membrane mode shapes are electrically generated although all points of the membrane do not pass through equilibrium at the same moments in time.
Morris, Mohy G
2010-02-28
With the rapid somatic growth and development in infants, simultaneous accurate measurements of lung volume and airway function are essential. Raised volume rapid thoracoabdominal compression (RTC) is widely used to generate forced expiration from an airway opening pressure of 30 cmH(2)O (V(30)). The (dynamic) functional residual capacity (FRC(dyn)) remains the lung volume most routinely measured. The aim of this study was to develop comprehensive integrated spirometry that included all subdivisions of lung volume at V(30) or total lung capacity (TLC(30)). Measurements were performed on 17 healthy infants aged 8.6-119.7 weeks. A commercial system for multiple-breath nitrogen washout (MBNW) to measure lung volumes and a custom made system to perform RTC were used in unison. A refined automated raised volume RTC and the following two novel single maneuvers with dual volume measurements were performed from V(30) during a brief post-hyperventilation apneic pause: (1) the passive expiratory flow was integrated to produce the inspiratory capacity (IC) and the static (passive) FRC (FRC(st)) was estimated by initiating MBNW after end-passive expiration; (2) RTC was initiated late during passive expiration, flow was integrated to produce the slow vital capacity ((j)SVC) and the residual volume (RV) was measured by initiating MBNW after end-expiration while the jacket (j) was inflated. Intrasubject FRC(dyn) and FRC(st) measurements overlapped (p=0.6420) but neither did with the RV (p<0.0001). Means (95% confidence interval) of FRC(dyn), IC, FRC(st), (j)SVC, RV, forced vital capacity and tidal volume were 21.2 (19.7-22.7), 36.7 (33.0-40.4), 21.2 (19.6-22.8), 40.7 (37.2-44.2), 18.1 (16.6-19.7), 40.7 (37.1-44.2) and 10.2 (9.6-10.7)ml/kg, respectively. Static lung volumes and capacities at V(30) and variables from the best forced expiratory flow-volume curve were dependent on age, body length and weight. In conclusion, we developed a comprehensive physiologically integrated approach for in-depth investigation of lung function at V(30) in infants. Copyright 2009 Elsevier B.V. All rights reserved.
Adaptive Technologies for Training and Education
ERIC Educational Resources Information Center
Durlach, Paula J., Ed; Lesgold, Alan M., Ed.
2012-01-01
This edited volume provides an overview of the latest advancements in adaptive training technology. Intelligent tutoring has been deployed for well-defined and relatively static educational domains such as algebra and geometry. However, this adaptive approach to computer-based training has yet to come into wider usage for domains that are less…
NASA Technical Reports Server (NTRS)
Nelson, D. P.
1981-01-01
Tabulated aerodynamic data from coannular nozzle performance tests are given for test runs 26 through 37. The data include nozzle thrust coefficient parameters, nozzle discharge coefficients, and static pressure tap measurements.
A comparison between the dynamics of horizontal and vertical axis offshore floating wind turbines.
Borg, M; Collu, M
2015-02-28
The need to further exploit offshore wind resources in deeper waters has led to a re-emerging interest in vertical axis wind turbines (VAWTs) for floating foundation applications. However, there has been little effort to systematically compare VAWTs to the more conventional horizontal axis wind turbine (HAWT). This article initiates this comparison based on prime principles, focusing on the turbine aerodynamic forces and their impact on the floating wind turbine static and dynamic responses. VAWTs generate substantially different aerodynamic forces on the support structure, in particular, a potentially lower inclining moment and a substantially higher torque than HAWTs. Considering the static stability requirements, the advantages of a lower inclining moment, a lower wind turbine mass and a lower centre of gravity are illustrated, all of which are exploitable to have a less costly support structure. Floating VAWTs experience increased motion in the frequency range surrounding the turbine [number of blades]×[rotational speed] frequency. For very large VAWTs with slower rotational speeds, this frequency range may significantly overlap with the range of wave excitation forces. Quantitative considerations are undertaken comparing the reference NREL 5 MW HAWT with the NOVA 5 MW VAWT. © 2015 The Author(s) Published by the Royal Society. All rights reserved.
1982-01-01
CONTRAVES GOEPZ CORP 309 8 FAIRCHILD CAMERA & INSTRUMENT CORP 101 B CONTROL DATA CORP 79 B FAIRCHILD INDUSTRIES IN^ 173 N CORNELL UN "’RSITY 249 B...MASS 530 383 MEGAPULSE INC S 1,276 - BEDFORD MASS 1.276 360 OPTI METRICS INC S 1,4S5 ANN ARSOR MICHIGAN 433 385 CONTRAVES GOERZ CORP 1,266 WHITE
Energy Demand and Resources of Japan. Volume 2
1973-08-01
the process. But if less coal per ton of steel is required, the countervailing fact remains that Japan, already a major steel pro- ducer, will...requirements between now and 2000 represent a prime marketing tar- get for the United States, provided the world economy remains reason- ably healthy and...today’s dollars, provided the U.S. remains competitive in the world coal market. B.4 Potential Technological Improvements B. 4.1 High-Speed Mining
Albu, Gergely; Wallin, Mats; Hallbäck, Magnus; Emtell, Per; Wolf, Andrew; Lönnqvist, Per-Arne; Göthberg, Sylvia; Peták, Ferenc; Habre, Walid
2013-07-01
Effective lung volume (ELV) for gas exchange is a new measure that could be used as a real-time guide during controlled mechanical ventilation. The authors established the relationships of ELV to static end-expiratory lung volume (EELV) with varying levels of positive end-expiratory pressure (PEEP) in healthy and surfactant-depleted rabbit lungs. Nine rabbits were anesthetized and ventilated with a modified volume-controlled mode where periods of five consecutive alterations in inspiratory/expiratory ratio (1:2-1.5:1) were imposed to measure ELV from the corresponding carbon dioxide elimination traces. EELV and the lung clearance index were concomitantly determined by helium wash-out technique. Airway and tissue mechanics were assessed by using low-frequency forced oscillations. Measurements were collected at PEEP 0, 3, 6, and 9 cm H2O levels under control condition and after surfactant depletion by whole-lung lavage. ELV was greater than EELV at all PEEP levels before lavage, whereas there was no evidence for a difference in the lung volume indices after surfactant depletion at PEEP 6 or 9 cm H2O. Increasing PEEP level caused significant parallel increases in both ELV and EELV levels, decreases in ventilation heterogeneity, and improvement in airway and tissue mechanics under control condition and after surfactant depletion. ELV and EELV exhibited strong and statistically significant correlations before (r=0.84) and after lavage (r=0.87). The parallel changes in ELV and EELV with PEEP in healthy and surfactant-depleted lungs support the clinical value of ELV measurement as a bedside tool to estimate dynamic changes in EELV in children and infants.
Johansen, B; Bjørtuft, O; Boe, J
1993-04-01
Single lung function is usually assessed by radioisotopes or, more rarely, by bronchospirometry in which a double lumen catheter is used to separate ventilation of the two lungs. The latter is more precise but less comfortable. An alternative bronchoscopic method is described for determining the volume of a single lung. One mainstem bronchus was temporarily occluded with an inflatable balloon during fibreoptic bronchoscopy in 12 healthy volunteers aged 18-29 years. The functional residual capacities (FRC) of the right, left, and both lungs were measured in duplicate by closed circuit helium dilution. Supplementary vital capacity (VC) manoeuvres permitted calculation of single lung capacities (TLC) and residual volumes (RV). The standard deviation of a single determination of capacities of the right, left, and both lungs were: TLC, 80, 96, and 308 ml; VC, 56, 139, 171 ml; FRC, 131, 74, and 287 ml; RV, 112, 185, and 303 ml, respectively. The sum of the right and left unilateral TLC was not different from bilateral TLC (6.12 v 5.95 l) and the sum of the unilateral FRC was not different from the bilateral FRC (2.60 v 2.78 l). The sum of the unilateral VC was lower than bilateral VC (4.52 v 4.80 l), that of the unilateral RV was higher than bilateral RV (1.60 v 1.16 l). For all subdivisions of lung volume, the right lung was larger than the left. The most common complaint was substernal discomfort during complete exhalation. Oxygen saturation rarely fell below 90%. Temporary occlusion of a mainstem bronchus in normal subjects is safe, relatively simple, and allows fairly precise and accurate measurements of unilateral static lung volumes. Occlusion at TLC, however, probably prevents proper emptying of the non-occluded lung.
Estimation of gas and tissue lung volumes by MRI: functional approach of lung imaging.
Qanadli, S D; Orvoen-Frija, E; Lacombe, P; Di Paola, R; Bittoun, J; Frija, G
1999-01-01
The purpose of this work was to assess the accuracy of MRI for the determination of lung gas and tissue volumes. Fifteen healthy subjects underwent MRI of the thorax and pulmonary function tests [vital capacity (VC) and total lung capacity (TLC)] in the supine position. MR examinations were performed at inspiration and expiration. Lung volumes were measured by a previously validated technique on phantoms. Both individual and total lung volumes and capacities were calculated. MRI total vital capacity (VC(MRI)) was compared with spirometric vital capacity (VC(SP)). Capacities were correlated to lung volumes. Tissue volume (V(T)) was estimated as the difference between the total lung volume at full inspiration and the TLC. No significant difference was seen between VC(MRI) and VC(SP). Individual capacities were well correlated (r = 0.9) to static volume at full inspiration. The V(T) was estimated to be 836+/-393 ml. This preliminary study demonstrates that MRI can accurately estimate lung gas and tissue volumes. The proposed approach appears well suited for functional imaging of the lung.
High pressure and high temperature apparatus
Voronov, Oleg A.
2005-09-13
A design for high pressure/high temperature apparatus and reaction cell to achieve .about.30 GPa pressure in .about.1 cm volume and .about.100 GPa pressure in .about.1 mm volumes and 20-5000.degree. C. temperatures in a static regime. The device includes profiled anvils (28) action on a reaction cell (14, 16) containing the material (26) to be processed. The reaction cell includes a heater (18) surrounded by insulating layers and screens. Surrounding the anvils are cylindrical inserts and supporting rings (30-48) whose hardness increases towards the reaction cell. These volumes may be increased considerably if applications require it, making use of presses that have larger loading force capability, larger frames and using larger anvils.
Apparatus for passive removal of subsurface contaminants and volume flow measurement
Jackson, Dennis G.; Rossabi, Joseph; Riha, Brian D.
2002-01-01
A system for improving the Baroball valve and a method for retrofitting an existing Baroball valve. This invention improves upon the Baroball valve by reshaping the interior chamber of the valve to form a flow meter measuring chamber. The Baroball valve sealing mechanism acts as a rotameter bob for determining volume flow rate through the Baroball valve. A method for retrofitting a Baroball valve includes providing static pressure ports and connecting a measuring device, to these ports, for measuring the pressure differential between the Baroball chamber and the well. A standard curve of nominal device measurements allows the volume flow rate to be determined through the retrofitted Baroball valve.
Quantifying hypoxia in human cancers using static PET imaging.
Taylor, Edward; Yeung, Ivan; Keller, Harald; Wouters, Bradley G; Milosevic, Michael; Hedley, David W; Jaffray, David A
2016-11-21
Compared to FDG, the signal of 18 F-labelled hypoxia-sensitive tracers in tumours is low. This means that in addition to the presence of hypoxic cells, transport properties contribute significantly to the uptake signal in static PET images. This sensitivity to transport must be minimized in order for static PET to provide a reliable standard for hypoxia quantification. A dynamic compartmental model based on a reaction-diffusion formalism was developed to interpret tracer pharmacokinetics and applied to static images of FAZA in twenty patients with pancreatic cancer. We use our model to identify tumour properties-well-perfused without substantial necrosis or partitioning-for which static PET images can reliably quantify hypoxia. Normalizing the measured activity in a tumour voxel by the value in blood leads to a reduction in the sensitivity to variations in 'inter-corporal' transport properties-blood volume and clearance rate-as well as imaging study protocols. Normalization thus enhances the correlation between static PET images and the FAZA binding rate K 3 , a quantity which quantifies hypoxia in a biologically significant way. The ratio of FAZA uptake in spinal muscle and blood can vary substantially across patients due to long muscle equilibration times. Normalized static PET images of hypoxia-sensitive tracers can reliably quantify hypoxia for homogeneously well-perfused tumours with minimal tissue partitioning. The ideal normalizing reference tissue is blood, either drawn from the patient before PET scanning or imaged using PET. If blood is not available, uniform, homogeneously well-perfused muscle can be used. For tumours that are not homogeneously well-perfused or for which partitioning is significant, only an analysis of dynamic PET scans can reliably quantify hypoxia.
Quantifying hypoxia in human cancers using static PET imaging
NASA Astrophysics Data System (ADS)
Taylor, Edward; Yeung, Ivan; Keller, Harald; Wouters, Bradley G.; Milosevic, Michael; Hedley, David W.; Jaffray, David A.
2016-11-01
Compared to FDG, the signal of 18F-labelled hypoxia-sensitive tracers in tumours is low. This means that in addition to the presence of hypoxic cells, transport properties contribute significantly to the uptake signal in static PET images. This sensitivity to transport must be minimized in order for static PET to provide a reliable standard for hypoxia quantification. A dynamic compartmental model based on a reaction-diffusion formalism was developed to interpret tracer pharmacokinetics and applied to static images of FAZA in twenty patients with pancreatic cancer. We use our model to identify tumour properties—well-perfused without substantial necrosis or partitioning—for which static PET images can reliably quantify hypoxia. Normalizing the measured activity in a tumour voxel by the value in blood leads to a reduction in the sensitivity to variations in ‘inter-corporal’ transport properties—blood volume and clearance rate—as well as imaging study protocols. Normalization thus enhances the correlation between static PET images and the FAZA binding rate K 3, a quantity which quantifies hypoxia in a biologically significant way. The ratio of FAZA uptake in spinal muscle and blood can vary substantially across patients due to long muscle equilibration times. Normalized static PET images of hypoxia-sensitive tracers can reliably quantify hypoxia for homogeneously well-perfused tumours with minimal tissue partitioning. The ideal normalizing reference tissue is blood, either drawn from the patient before PET scanning or imaged using PET. If blood is not available, uniform, homogeneously well-perfused muscle can be used. For tumours that are not homogeneously well-perfused or for which partitioning is significant, only an analysis of dynamic PET scans can reliably quantify hypoxia.
The 'fixed cost effect' on practice management.
Tipton, E F; Finley, J B
1999-01-01
To obtain a better understanding of the behavior of "non-professional" costs in a medical practice, the authors analyzed the expenses of a 19-doctor practice. The analysis revealed that 80 percent of these expenses were fixed costs. Fixed costs, as opposed to variable costs, remain static in total but vary on a per unit basis as volume changes. Organizations with high fixed cost must maximize capacity to achieve profitability. Thus, the relationship among volume, capacity, cost and profit must be understood by medical practices negotiating rates for service units.
Socio-cognitive load and social anxiety in an emotional anti-saccade task
Butler, Stephen H.; Grealy, Madeleine A.
2018-01-01
The anti-saccade task has been used to measure attentional control related to general anxiety but less so with social anxiety specifically. Previous research has not been conclusive in suggesting that social anxiety may lead to difficulties in inhibiting faces. It is possible that static face paradigms do not convey a sufficient social threat to elicit an inhibitory response in socially anxious individuals. The aim of the current study was twofold. We investigated the effect of social anxiety on performance in an anti-saccade task with neutral or emotional faces preceded either by a social stressor (Experiment 1), or valenced sentence primes designed to increase the social salience of the task (Experiment 2). Our results indicated that latencies were significantly longer for happy than angry faces. Additionally, and surprisingly, high anxious participants made more erroneous anti-saccades to neutral than angry and happy faces, whilst the low anxious groups exhibited a trend in the opposite direction. Results are consistent with a general approach-avoidance response for positive and threatening social information. However increased socio-cognitive load may alter attentional control with high anxious individuals avoiding emotional faces, but finding it more difficult to inhibit ambiguous faces. The effects of social sentence primes on attention appear to be subtle but suggest that the anti-saccade task will only elicit socially relevant responses where the paradigm is more ecologically valid. PMID:29795619
NASA Astrophysics Data System (ADS)
Delhaye, Robert; Rath, Volker; Jones, Alan G.; Muller, Mark R.; Reay, Derek
2017-05-01
Galvanic distortions of magnetotelluric (MT) data, such as the static-shift effect, are a known problem that can lead to incorrect estimation of resistivities and erroneous modelling of geometries with resulting misinterpretation of subsurface electrical resistivity structure. A wide variety of approaches have been proposed to account for these galvanic distortions, some depending on the target area, with varying degrees of success. The natural laboratory for our study is a hydraulically permeable volume of conductive sediment at depth, the internal resistivity structure of which can be used to estimate reservoir viability for geothermal purposes; however, static-shift correction is required in order to ensure robust and precise modelling accuracy.We present here a possible method to employ frequency-domain electromagnetic data in order to correct static-shift effects, illustrated by a case study from Northern Ireland. In our survey area, airborne frequency domain electromagnetic (FDEM) data are regionally available with high spatial density. The spatial distributions of the derived static-shift corrections are analysed and applied to the uncorrected MT data prior to inversion. Two comparative inversion models are derived, one with and one without static-shift corrections, with instructive results. As expected from the one-dimensional analogy of static-shift correction, at shallow model depths, where the structure is controlled by a single local MT site, the correction of static-shift effects leads to vertical scaling of resistivity-thickness products in the model, with the corrected model showing improved correlation to existing borehole wireline resistivity data. In turn, as these vertical scalings are effectively independent of adjacent sites, lateral resistivity distributions are also affected, with up to half a decade of resistivity variation between the models estimated at depths down to 2000 m. Simple estimation of differences in bulk porosity, derived using Archie's Law, between the two models reinforces our conclusion that the suborder of magnitude resistivity contrasts induced by the correction of static shifts correspond to similar contrasts in estimated porosities, and hence, for purposes of reservoir investigation or similar cases requiring accurate absolute resistivity estimates, galvanic distortion correction, especially static-shift correction, is essential.
Lung volumes and maximal respiratory pressures in collegiate swimmers and runners.
Cordain, L; Tucker, A; Moon, D; Stager, J M
1990-03-01
To determine whether respiratory muscle strength is related to pulmonary volume differences in athletes and nonathletes, 11 intercollegiate female swimmers, 11 female cross-country runners, and two nonathletic control groups, matched to the athletes in height and age, were evaluated for pulmonary parameters including maximal inspiratory pressure (PImax) and maximal expiratory pressure (PEmax). Swimmers exhibited larger (p less than .05) vital capacities (VC), residual lung volumes (RV), inspiratory capacities (IC), and functional residual capacities (FRC) than both the runners or the controls but no difference (p greater than .05) in either PImax or inspiratory flow (FIV 25%-75%). Timed expiratory volumes (FEV 0.5 and FEV 1.0) were significantly (p less than .05) lower in the swimmers than in the controls. These data suggest that an adaptational growth may be responsible, in part, for the augmented static lung volumes demonstrated in swimmers.
Vacuum-assisted venous return reduces blood usage.
Banbury, Michael K; White, Jennifer A; Blackstone, Eugene H; Cosgrove, Delos M
2003-09-01
To determine whether vacuum-assisted venous return has clinical advantages over conventional gravity drainage apart from allowing the use of smaller cannulas and shorter tubing. A total of 150 valve operations were performed at our institution between February and July 1999 using vacuum-assisted venous return with small venous cannulas connected to short tubing. These were compared with (1) 83 valve operations performed between April 1997 and January 1998 using the initial version of vacuum-assisted venous return, and (2) 124 valve operations performed between January and April of 1997 using conventional gravity drainage. Priming volume, hematocrit value, red blood cell usage, and total blood product usage were compared multivariably. These comparisons were covariate and propensity adjusted for dissimilarities between the groups and confirmed by propensity-matched pairs analysis. Priming volume was 1.4 +/- 0.4 L for small-cannula vacuum-assisted venous return, 1.7 +/- 0.4 L for initial vacuum-assisted venous return, and 2.0 +/- 0.4 L for gravity drainage (P <.0001). Smaller priming resulted in higher hematocrit values both at the beginning of cardiopulmonary bypass (27% +/- 5% compared with 26% +/- 4% and 25% +/- 4%, respectively, P <.0001) and at the end (30% +/- 4% compared with 28% +/- 4% and 27% +/- 4%, respectively, P <.0001). Red cell transfusions were used in 17% of the patients having small-cannula vacuum-assisted venous return, 27% of the initial patients having vacuum-assisted venous return, and 37% of the patients having gravity drainage (P =.001); total blood product usage was 19%, 27%, and 39%, respectively (P =.002). Although ministernotomy also was associated with reduced blood product usage (P <.004), propensity matching on type of sternotomy confirmed the association of vacuum-assisted venous return with lowered blood product usage. Vacuum-assisted venous return results in (1) higher hematocrit values during cardiopulmonary bypass and (2) decreased red cell and total blood product usage.
Potential uses of vacuum bubbles in noise and vibration control
NASA Technical Reports Server (NTRS)
Ver, Istvan L.
1989-01-01
Vacuum bubbles are new acoustic elements which are dynamically more compliant than the gas volume they replace, but which are statically robust. They are made of a thin metallic shell with vacuum in their cavity. Consequently, they pose no danger in terms of contamination or fire hazard. The potential of the vacuum bubble concept for noise and vibration control was assessed with special emphases on spacecraft and aircraft applications. The following potential uses were identified: (1) as a cladding, to reduce sound radiation of vibrating surfaces and the sound excitation of structures, (2) as a screen, to reflect or absorb an incident sound wave, and (3) as a liner, to increase low frequency sound transmission loss of double walls and to increase the low frequency sound attenuation of muffler baffles. It was found that geometric and material parameters must be controlled to a very high accuracy to obtain optimal performance and that performance is highly sensitive to variations in static pressure. Consequently, it was concluded that vacuum bubbles have more potential in spacecraft applications where static pressure is controlled more than in aircraft applications where large fluctuations in static pressure are common.
Numerical study on the aerodynamic characteristics of both static and flapping wing with attachments
NASA Astrophysics Data System (ADS)
Xie, Lingwang; Zhang, Xingwei; Luo, Pan; Huang, Panpan
2017-10-01
The purpose of this paper is to investigate the aerodynamic mechanism of airfoils under different icing situations which are different icing type, different icing time, and different icing position. Numerical simulation is carried out by using the finite volume method for both static and flapping airfoils, when Reynolds number is kept at 135000. The difference of aerodynamic performance between the airfoil with attachments and without attachments are be investigated by comparing the force coefficients, lift-to-drag ratios and flow field contour. The present simulations reveal that some influences of attachment are similar in the static airfoil and the flapping airfoil. Specifically, the airfoil with the attachment derived from glaze ice type causes the worse aerodynamic performance than that derived from rime ice type. The longer the icing time, the greater influence of aerodynamic performance the attachment causes. The attachments on the leading-edge have the greater influence of aerodynamic performance than other positions. Moreover, there are little differences between the static airfoil and the flapping airfoil. Compared with the static airfoil, the flapping airfoil which attachment located on the trailing edge causes a worse aerodynamic performance. Both attachments derived from rime ice type and glaze ice type all will deteriorate the aerodynamic performance of the asymmetrical airfoils. Present work provides the systematic and comprehensive study about icing blade which is conducive to the development of the wind power generation technology.
NASA Technical Reports Server (NTRS)
1978-01-01
Sea level, static, ground testing of the over-the-wing engine and boilerplate nacelle components was performed. The equipment tested and the test facility are described. Summaries of the instrumentations, the chronological history of the tests, and the test results are presented.
49 CFR 238.405 - Longitudinal static compressive strength.
Code of Federal Regulations, 2010 CFR
2010-10-01
... volumes of a power car or a trailer car designed to crush as part of the crash energy management design... deformation to the cab, unless equivalent protection to crewmembers is provided under an alternate design approach, validated through analysis and testing, and approved by FRA under the provisions of § 238.21. (b...
49 CFR 238.405 - Longitudinal static compressive strength.
Code of Federal Regulations, 2011 CFR
2011-10-01
... volumes of a power car or a trailer car designed to crush as part of the crash energy management design... deformation to the cab, unless equivalent protection to crewmembers is provided under an alternate design approach, validated through analysis and testing, and approved by FRA under the provisions of § 238.21. (b...
NASA Technical Reports Server (NTRS)
Allen, E. C., Jr.; Eder, F. W.
1972-01-01
Test results of booster and orbiter models of various component buildup configurations are reported. Dataset Collation Sheets, which give a complete summary of the configurations, are presented along with a description of the test facility. Data reduction procedures are described.
Validity and Reliability of Tympanometric Measures for Pediatric Patients.
ERIC Educational Resources Information Center
Karzon, Roanne G.
1991-01-01
Sensitivity and specificity of static acoustic admittance (SAA) and tympanometric width (TW) were assessed for 116 pediatric patients. A statistically significant change in SAA was observed in immediate repeat measures. No significant change across the two sequential measures was observed for TW, peak pressure, or the estimate of ear canal volume.…
Ocean Engineering Studies Compiled 1991. Volume 10. External Pressure Housing - Concrete
1991-01-01
Hafsklold Ing. F. Selmer AS Anton Brandtzaeg Post Office Box 256 Professor of Construction & Harbour Oslo, Norway Engineering Norwegian Technical University...1984, pp 364-411. 50. 0. Olsen , "Implosion analysis of concrete cylinders under hydro- static pressure," ACI, vol 75, no. 3, Mar 1973, pp 82-85. 51. K.P
Investigations of static properties of two-dimensional bulk polymer systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bishop, M.; Ceperley, D.; Frisch, H.L.
1981-12-01
The static properties of two dimensional excluded volume continuum multichain systems are investigated by a ''reptation'' Monte Carlo algorithm. All beads interact via a repulsive (shifted) Lennard-Jones potential. In addition, nearest neighbors along chains are linked by a quasiharmonic potential which permits limited pair extensions. Chain lengths of 5, 10, 20, 32, 50, and 70 beads have been studied. Studies at densities of 0.1, 0.3, and 0.5 demonstrate that chain dimensions are compressed as the concentration is increased. Both the mean square end-to-end distance , and the mean square radius of gyration have a power law dependence upon l-1,more » the number of bonds, with exponent approximately 1.44 for rho = 0.1, 1.33 for rho = 0.3, and 1.20 for rho = 0.5. The asphericity ratios indicate the extent of compression as the density is increased. In addition, nonexcluded volume chains are studied via straightforward Monte Carlo integration. and have a power law dependence upon l-1 with exponent 1.00.« less
Static magnetism and thermal switching in randomly oriented L10 FePt thin films
NASA Astrophysics Data System (ADS)
Lisfi, A.; Pokharel, S.; Alqarni, A.; Akioya, O.; Morgan, W.; Wuttig, M.
2018-05-01
Static magnetism and thermally activated magnetic relaxation were investigated in granular FePt films (20 nm-200 nm thick) with random magnetic anisotropy through hysteresis loop, torque curve and magnetization time dependence measurements. While the magnetism of thicker film (200 nm thick) is dominated by a single switching of the ordered L10 phase, thinner film (20 nm) displays a double switching, which is indicative of the presence of the disordered cubic phase. The pronounced behavior of double switching in thinner film suggests that the film grain boundary is composed of soft cubic magnetic phase. The magnetic relaxation study reveals that magnetic viscosity S of the films is strongly dependent on the external applied field and exhibits a maximum value (12 kAm) around the switching field and a vanishing behavior at low (1 kOe) and large (12 kOe) fields. The activation volume of the thermal switching was found to be much smaller than the physical volume of the granular structure due to the incoherent rotation mode of the magnetization reversal mechanism, which is established to be domain wall nucleation.
Implementing Embedded Training (ET): Volume 4. Identifying ET Requirements
1988-11-01
procedures that support the effective co::sidet·;,tion, definition, development , and integration of e::1 11cddcd trzd;Li:1r; (ET) ;~.:1p:1bilities...an effective ET compo- nent would be impossible or have undesired schedule or cost impacts. Iteration Two: Early System Development Once the new...ET. These needs can sometimes have a significant effect on the design of the prime item system. It is critical that materiel developers be made aware
1988-04-01
RESISTANCE, AS WELL AS GUIDELINES FROM APPROPRIATE AEROSPACE SPECIFICATIONS; MATERIALS WILL INCLUDE ALUMINUM AND TITANIUM ALLOYS, PLUS A FEW STEELS...VAPOR SYNTHESIS OF NIOBIUM ALUMINIDES TOPIC# 105 OFFICE: AFWAL/ML DIRECT SYNTHESIS OF NbA1 ALLOY FOILS BY CHEMICAL VAPOR DEPOSITION ONTO INERT SUBSTRATES...GROWT OF GAMMA PRIME NICKEL ALUMINIDE (Ni3AI) %% TOPICt 104 OFFICE: AFWAL/ML . SMALL BUSINESS INNOVATION RESEARCH (SBIR) PROGRAM - PHASE 1 PAGE 555
Naval Postgraduate School Research. Volume 11, Number 2, June 2001
2001-06-01
Asynchronous Transfer Mode Protocols for Communi- cation of TCP / IP Based Voice, Video and Data over Long Delay Wireless Links.” LCDR Bermingham is...accurate, DD-21 is planned to employ an Integrated Power System ( IPS ), where both ship service and ship propulsion power are derived from a common set...electric drive and to shipboard distribu- tion. The advantages of electric drive and IPS are manifold including: a reduction in the number of prime movers
1975-01-01
NEN ENGLAND EOUTPHENT CO INC • 269 8 PULSEPONER SYSTENS INC TPA N NEW NEXICO INSTITUTE WINING + TECH * 151 N PUROUE RESEARCH FOUNDATION q- NMEN MEXICO...ANAQOSf S u SHALL USyNeESS -1T -- U - - e* I.- U~ SE~tION I -U.S. aUSINEsS 3 IRMS FISCAL Ville 1979 RawN low Or G.ATOR THOUSANOS . 044K NAME OF
Photomask repeater strategy for high-quality and low-cost reticle fabrication
NASA Astrophysics Data System (ADS)
Kyoh, Suigen; Inoue, Soichi; Ikenaga, Osamu; Higaki, Tomotaka; Shigemitsu, Fumiaki; Mori, Ichiro; Kokubo, Haruo; Hayashi, Naoya; Irie, Nobuyuki; Ishii, Yuki; Umatate, Toshikazu
2003-08-01
The severe mask specification makes mask cost increase drastically. Especially, the increase in the mask cost deals ASIC businesses a fatal blow due to its small chip volume per product. Pattern writing cost has always occupied the main part of the prime mask cost and the emphasis of this is still increasing. This paper reports on a Photomask Repeater strategy to be a solution for reducing mask cost in pattern writing, comparing with conventional EB system.
2002-05-13
the identification of reason as the prime human faculty and virtue, i.e., sense of excellence and practical wisdom as the highest good. These are the...Clothes, " National Security Studies Quarterly Spring 2000, Volume VI, Issue 2, pp. 59-71. 43 Glynis Breakwell and Keith Spacie , Pressures Facing...commander to draw upon, then what is the solution to reduce the stressors highlighted by the Breakwell and Spacie study? Can there be operational
CTC Sentinel. Volume 4, Issue 10, October 2011
2011-10-01
few of the tapes are duplicates, and handwriting on cassette cartridges suggest provenance from diverse us- ers. In its prime, the archive was most...enemy- 57 “58% in AP Say Naxalism is Good, Finds TOI Poll,” Times of India, September 28, 2010. Although the survey did not specifically pose questions...translated by al- `Awlaqi, stated: In our miserable time, he says , in this miserable time, we need to go back to the constants, because we find some
Air and Space Power Journal. Volume 16, Number 3, Fall 2002
2002-01-01
undersea sensor grid. The prehostilities phase of any crisis is a prime period for special operations—especially in the ISR role. SOF operations...application abound: Adolf Hitler’s references to the Luftwaffe dur ing the reoccupation of the Rhineland in 1936 or the Munich crisis of 1938...Kennedy’s reliance on Strategic Air Command’s B-52s and missile force during the Cuban missile crisis of 1962, among others. Although the framework
Estimating Equivalency of Explosives Through A Thermochemical Approach
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maienschein, J L
2002-07-08
The Cheetah thermochemical computer code provides an accurate method for estimating the TNT equivalency of any explosive, evaluated either with respect to peak pressure or the quasi-static pressure at long time in a confined volume. Cheetah calculates the detonation energy and heat of combustion for virtually any explosive (pure or formulation). Comparing the detonation energy for an explosive with that of TNT allows estimation of the TNT equivalency with respect to peak pressure, while comparison of the heat of combustion allows estimation of TNT equivalency with respect to quasi-static pressure. We discuss the methodology, present results for many explosives, andmore » show comparisons with equivalency data from other sources.« less
Synthesis of polymer ion-exchange hydrogels under γ - irradiation 60Co
NASA Astrophysics Data System (ADS)
Le, V. M.; Zhevnyak, V. D.; Pak, V. Kh; Ananev, V. A.; Borodin, U. V.
2015-04-01
We have reported earlier about the modification of ion-exchange hydrogel under the influence of gamma radiation. The optimal absorbed dose of irradiation had been choosen for radiation modification of polymer hydrogels by ionits to produce products with a high content of the gel - fractions and sufficient mechanical properties. The dependence of the static exchange capacity of hydrogels on the type of ionit and its fractional composition had been studied. The dependence of the static exchange capacity of the quantitative composition of the ionit in the volume of the hydrogel had been investigated. The ion-exchange medical eye lenses had been made under selected conditions of synthesis. Their sorption properties had been studied.
NASA Technical Reports Server (NTRS)
Allen, E. C.; Eder, F. W.
1972-01-01
Experimental aerodynamic investigations have been made on a .0035 scale model North American Rockwell/General Dynamics version of the space shuttle. Static stability and control data were obtained on the delta wing booster alone (B-20) and with the delta wing orbiter (134D) mounted in various positions on the booster. Six component aerodynamic force and moment data were recorded over an angle of attack range from -10 deg to 24 deg at 0 deg and 6 deg sideslip angles and from -10 deg to +10 deg sideslip at 0 deg angle of attack. Mach number ranged from 0.6 to 4.96.
Jin, Si Hyung; Jeong, Heon-Ho; Lee, Byungjin; Lee, Sung Sik; Lee, Chang-Soo
2015-01-01
We present a programmable microfluidic static droplet array (SDA) device that can perform user-defined multistep combinatorial protocols. It combines the passive storage of aqueous droplets without any external control with integrated microvalves for discrete sample dispensing and dispersion-free unit operation. The addressable picoliter-volume reaction is systematically achieved by consecutively merging programmable sequences of reagent droplets. The SDA device is remarkably reusable and able to perform identical enzyme kinetic experiments at least 30 times via automated cross-contamination-free removal of droplets from individual hydrodynamic traps. Taking all these features together, this programmable and reusable universal SDA device will be a general microfluidic platform that can be reprogrammed for multiple applications.
Multipoint vibrometry with dynamic and static holograms.
Haist, T; Lingel, C; Osten, W; Winter, M; Giesen, M; Ritter, F; Sandfort, K; Rembe, C; Bendel, K
2013-12-01
We report on two multipoint vibrometers with user-adjustable position of the measurement spots. Both systems are using holograms for beam deflection. The measurement is based on heterodyne interferometry with a frequency difference of 5 MHz between reference and object beam. One of the systems uses programmable positioning of the spots in the object volume but is limited concerning the light efficiency. The other system is based on static holograms in combination with mechanical adjustment of the measurement spots and does not have such a general efficiency restriction. Design considerations are given and we show measurement results for both systems. In addition, we analyze the sensitivity of the systems which is a major limitation compared to single point scanning systems.
NASA Technical Reports Server (NTRS)
Ramsey, P. E.; Winkler, G. W.
1975-01-01
Static pressure distributions for the external tank (ET) at reentry conditions are presented. Basic configuration of the model was the MCR 0200 ET modified to include a rectangular crossbar at the aft ET/orbiter attach point. Mach numbers were 1.96, 3.48, and 4.96. Reynolds number per foot at these Mach numbers were 6.95 million, 6.42 million, and 4.95 million, respectively. Angle of attack range was -8 to 100 degrees and roll angle was 0 to 315 degrees.
Gravity currents in rotating channels. Part 1. Steady-state theory
NASA Astrophysics Data System (ADS)
Hacker, J. N.; Linden, P. F.
2002-04-01
A theory is developed for the speed and structure of steady-state non-dissipative gravity currents in rotating channels. The theory is an extension of that of Benjamin (1968) for non-rotating gravity currents, and in a similar way makes use of the steady-state and perfect-fluid (incompressible, inviscid and immiscible) approximations, and supposes the existence of a hydrostatic ‘control point’ in the current some distance away from the nose. The model allows for fully non-hydrostatic and ageostrophic motion in a control volume V ahead of the control point, with the solution being determined by the requirements, consistent with the perfect-fluid approximation, of energy and momentum conservation in V, as expressed by Bernoulli's theorem and a generalized flow-force balance. The governing parameter in the problem, which expresses the strength of the background rotation, is the ratio W = B/R, where B is the channel width and R = (g[prime prime or minute]H)1/2/f is the internal Rossby radius of deformation based on the total depth of the ambient fluid H. Analytic solutions are determined for the particular case of zero front-relative flow within the gravity current. For each value of W there is a unique non-dissipative two-layer solution, and a non-dissipative one-layer solution which is specified by the value of the wall-depth h0. In the two-layer case, the non-dimensional propagation speed c = cf(g[prime prime or minute]H)[minus sign]1/2 increases smoothly from the non-rotating value of 0.5 as W increases, asymptoting to unity for W [rightward arrow] [infty infinity]. The gravity current separates from the left-hand wall of the channel at W = 0.67 and thereafter has decreasing width. The depth of the current at the right-hand wall, h0, increases, reaching the full depth at W = 1.90, after which point the interface outcrops on both the upper and lower boundaries, with the distance over which the interface slopes being 0.881R. In the one-layer case, the wall-depth based propagation speed Froude number c0 = cf(g[prime prime or minute]h0)[minus sign]1/2 = 21/2, as in the non-rotating one-layer case. The current separates from the left-hand wall of the channel at W0 [identical with] B/R0 = 2[minus sign]1/2, and thereafter has width 2[minus sign]1/2R0, where R0 = (g[prime prime or minute]h0)1/2/f is the wall-depth based deformation radius.
NASA Astrophysics Data System (ADS)
Zhang, Xuhui; Xia, Lei; Hao, Shaojun; Chen, Weiliang; Guo, Junyi; Ma, Zhenzhen; Wang, Huamin; Kong, Xuejun; Wang, Hongyu; Zhang, Zhengchen
2018-04-01
To observe the effect of intravenous bone pain Capsule on the ear of mice induced by xylene, swelling of rat models of cervical spondylosis. Weighing 18 ˜ 21g 50 mice, male, were randomly divided into for five groups, which were fed with service for bone pain static capsule suspension, Jingfukang granule suspension 0.5%CMC liquid and the same volume of. Respectively to the mice ear drop of xylene 0.05 ml, 4h after cervical dislocation, the mice were sacrificed and the cut two ear, rapid analytical balance weighing, and calculate the ear swelling degree and the other to take the weight of 200 - 60 250g male SD rats, were randomly divided into for 6 groups, 10 rats in each group, of which 5 groups made cervical spondylosis model. Results: with the blank group than bone pain static capsule group and Jingfukang granule group can significantly reduce mouse auricular dimethylbenzene swelling, significantly reduce ear swelling degree (P < 0.01); the successful establishment of the rat model of cervical spondylosis. With the model group ratio, large, medium and small dose of bone pain static capsule group, Jingfukang granule group (P < 0.01) angle of swash plate of rats increased significantly, the high and middle dose of bone pain static capsule group, Jingfukang granule group can significantly reduce the rat X-ray scores (P < 0.05). Bone pain static capsule can significantly reduce mouse auricular dimethylbenzene swelling. The bone pain capsule has a good effect on the rat model of cervical spondylosis.
NASA Astrophysics Data System (ADS)
Benedek, Judit; Papp, Gábor; Kalmár, János
2018-04-01
Beyond rectangular prism polyhedron, as a discrete volume element, can also be used to model the density distribution inside 3D geological structures. The calculation of the closed formulae given for the gravitational potential and its higher-order derivatives, however, needs twice more runtime than that of the rectangular prism computations. Although the more detailed the better principle is generally accepted it is basically true only for errorless data. As soon as errors are present any forward gravitational calculation from the model is only a possible realization of the true force field on the significance level determined by the errors. So if one really considers the reliability of input data used in the calculations then sometimes the "less" can be equivalent to the "more" in statistical sense. As a consequence the processing time of the related complex formulae can be significantly reduced by the optimization of the number of volume elements based on the accuracy estimates of the input data. New algorithms are proposed to minimize the number of model elements defined both in local and in global coordinate systems. Common gravity field modelling programs generate optimized models for every computation points ( dynamic approach), whereas the static approach provides only one optimized model for all. Based on the static approach two different algorithms were developed. The grid-based algorithm starts with the maximum resolution polyhedral model defined by 3-3 points of each grid cell and generates a new polyhedral surface defined by points selected from the grid. The other algorithm is more general; it works also for irregularly distributed data (scattered points) connected by triangulation. Beyond the description of the optimization schemes some applications of these algorithms in regional and local gravity field modelling are presented too. The efficiency of the static approaches may provide even more than 90% reduction in computation time in favourable situation without the loss of reliability of the calculated gravity field parameters.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, C; Zhang, H; Chen, Y
Purpose: Recently, compressed sensing (CS) based iterative reconstruction (IR) method is receiving attentions to reconstruct high quality cone beam computed tomography (CBCT) images using sparsely sampled or noisy projections. The aim of this study is to develop a novel baseline algorithm called Mask Guided Image Reconstruction (MGIR), which can provide superior image quality for both low-dose 3DCBCT and 4DCBCT under single mathematical framework. Methods: In MGIR, the unknown CBCT volume was mathematically modeled as a combination of two regions where anatomical structures are 1) within the priori-defined mask and 2) outside the mask. Then we update each part of imagesmore » alternatively thorough solving minimization problems based on CS type IR. For low-dose 3DCBCT, the former region is defined as the anatomically complex region where it is focused to preserve edge information while latter region is defined as contrast uniform, and hence aggressively updated to remove noise/artifact. In 4DCBCT, the regions are separated as the common static part and moving part. Then, static volume and moving volumes were updated with global and phase sorted projection respectively, to optimize the image quality of both moving and static part simultaneously. Results: Examination of MGIR algorithm showed that high quality of both low-dose 3DCBCT and 4DCBCT images can be reconstructed without compromising the image resolution and imaging dose or scanning time respectively. For low-dose 3DCBCT, a clinical viable and high resolution head-and-neck image can be obtained while cutting the dose by 83%. In 4DCBCT, excellent quality 4DCBCT images could be reconstructed while requiring no more projection data and imaging dose than a typical clinical 3DCBCT scan. Conclusion: The results shown that the image quality of MGIR was superior compared to other published CS based IR algorithms for both 4DCBCT and low-dose 3DCBCT. This makes our MGIR algorithm potentially useful in various on-line clinical applications. Provisional Patent: UF#15476; WGS Ref. No. U1198.70067US00.« less
NASA Astrophysics Data System (ADS)
Verma, Rahul; Icardi, Matteo; Prodanović, Maša
2018-05-01
Understanding of pore-scale physics for multiphase flow in porous media is essential for accurate description of various flow phenomena. In particular, capillarity and wettability strongly influence capillary pressure-saturation and relative permeability relationships. Wettability is quantified by the contact angle of the fluid-fluid interface at the pore walls. In this work we focus on the non-trivial interface equilibria in presence of non-neutral wetting and complex geometries. We quantify the accuracy of a volume-of-fluid (VOF) formulation, implemented in a popular open-source computational fluid dynamics code, compared with a new formulation of a level set (LS) method, specifically developed for quasi-static capillarity-dominated displacement. The methods are tested in rhomboidal packings of spheres for a range of contact angles and for different rhomboidal configurations and the accuracy is evaluated against the semi-analytical solutions obtained by Mason and Morrow (1994). While the VOF method is implemented in a general purpose code that solves the full Navier-Stokes (NS) dynamics in a finite volume formulation, with additional terms to model surface tension, the LS method is optimized for the quasi-static case and, therefore, less computationally expensive. To overcome the shortcomings of the finite volume NS-VOF system for low capillary number flows, and its computational cost, we introduce an overdamped dynamics and a local time stepping to speed up the convergence to the steady state, for every given imposed pressure gradient (and therefore saturation condition). Despite these modifications, the methods fundamentally differ in the way they capture the interface, as well as in the number of equations solved and in the way the mean curvature (or equivalently capillary pressure) is computed. This study is intended to provide a rigorous validation study and gives important indications on the errors committed by these methods in solving more complex geometry and dynamics, where usually many sources of errors are interplaying.
NASA Astrophysics Data System (ADS)
Mann, P.; Witte, M.; Moser, T.; Lang, C.; Runz, A.; Johnen, W.; Berger, M.; Biederer, J.; Karger, C. P.
2017-01-01
In this study, we developed a new setup for the validation of clinical workflows in adaptive radiation therapy, which combines a dynamic ex vivo porcine lung phantom and three-dimensional (3D) polymer gel dosimetry. The phantom consists of an artificial PMMA-thorax and contains a post mortem explanted porcine lung to which arbitrary breathing patterns can be applied. A lung tumor was simulated using the PAGAT (polyacrylamide gelatin gel fabricated at atmospheric conditions) dosimetry gel, which was evaluated in three dimensions by magnetic resonance imaging (MRI). To avoid bias by reaction with oxygen and other materials, the gel was collocated inside a BAREX™ container. For calibration purposes, the same containers with eight gel samples were irradiated with doses from 0 to 7 Gy. To test the technical feasibility of the system, a small spherical dose distribution located completely within the gel volume was planned. Dose delivery was performed under static and dynamic conditions of the phantom with and without motion compensation by beam gating. To verify clinical target definition and motion compensation concepts, the entire gel volume was homogeneously irradiated applying adequate margins in case of the static phantom and an additional internal target volume in case of dynamically operated phantom without and with gated beam delivery. MR-evaluation of the gel samples and comparison of the resulting 3D dose distribution with the planned dose distribution revealed a good agreement for the static phantom. In case of the dynamically operated phantom without motion compensation, agreement was very poor while additional application of motion compensation techniques restored the good agreement between measured and planned dose. From these experiments it was concluded that the set up with the dynamic and anthropomorphic lung phantom together with 3D-gel dosimetry provides a valuable and versatile tool for geometrical and dosimetrical validation of motion compensated treatment concepts in adaptive radiotherapy.
Dynamic and static fluctuations in polymer gels studied by neutron spin-echo
NASA Astrophysics Data System (ADS)
Kanaya, T.; Takahashi, N.; Nishida, K.; Seto, H.; Nagao, M.; Takeba, Y.
2006-11-01
We report neutron spin-echo measurements on three types of poly(vinyl alcohol) (PVA) gels. The first is PVA gel in a mixture of dimethyl sulfoxide (DMSO) and water with volume ratio 60/40, the second is PVA gel in an aqueous borax solution and the third is chemically cross-linked PVA gel. The observed normalized intermediate scattering functions I( Q, t)/ I( Q,0) were very different among them. The I( Q, t)/ I( Q,0) of the first and third gels showed a non-decaying component in addition to a decaying component, but the second one did not have the non-decaying one. This clearly indicates that the fluctuations in the first and third PVA gels consist of static and dynamic fluctuations whereas the second PVA gel does include only the dynamic fluctuations. The dynamic and static fluctuations of the PVA gels were analyzed in terms of a restricted motion in the gel network and the Zimm motion, respectively.
Aeroelastic Deformation Measurements of Flap, Gap, and Overhang on a Semispan Model
NASA Technical Reports Server (NTRS)
Burner, A. W.; Liu, Tianshu; Garg, Sanjay; Ghee, Terence A.; Taylor, Nigel J.
2000-01-01
Single-camera, single-view videogrammetry has been used to determine static aeroelastic deformation of a slotted flap configuration on a semispan model at the National Transonic Facility (NTF). Deformation was determined by comparing wind-off to wind-on spatial data from targets placed on the main element, shroud, and flap of the model. Digitized video images from a camera were recorded and processed to automatically determine target image plane locations that were then corrected for sensor, lens, and frame grabber spatial errors. The videogrammetric technique has been established at NASA facilities as the technique of choice when high-volume static aeroelastic data with minimum impact on data taking is required. The primary measurement at the NTF with this technique in the past has been the measurement of static aeroelastic wing twist on full span models. The first results using the videogrammetric technique for the measurement of component deformation during semispan testing at the NTF are presented.
BSM Delta Qualification 2, volume 2
NASA Technical Reports Server (NTRS)
1994-01-01
This report, presented in three volumes, provides the results of a two-motor Delta Qualification 2 program conducted in 1993 to certify the following enhancements for incorporation into booster separation motor (BSM) flight hardware: vulcanized-in-place nozzle aft closure insulation; new iso-static ATJ bulk graphite throat insert material; adhesive EA 9394 for bonding the nozzle throat, igniter grain rod/centering insert/igniter case; deletion of the igniter adapter insulator ring; deletion of the igniter adapter/igniter case interface RTV; and deletion of loctite from igniter retainer plate threads. The enhancements above directly resulted from (1) the BSM total quality management (TQM) team initiatives to enhance the BSM producibility, and (2) the necessity to qualify new throat insert and adhesive systems to replace existing materials that will not be available. Testing was completed at both the component and motor levels. Component testing was accomplished to screen candidate materials (e.g., throat materials, adhesive systems) and to optimize processes (e.g., aft closure insulator vulcanization approach) prior to their incorporation into the test motors. Motor tests -- consisting of two motors, randomly selected by USBI's on-site quality personnel from production lot AAY, which were modified to accept the enhancements -- were completed to provide the final qualification of the enhancements for incorporation into flight hardware. Volume 2 details the environmental testing (vibration and shock) conducted at Marshall Space Flight Center (MSFC) to which the motors were subjected prior to static tests.
Donti, Olyvia; Tsolakis, Charilaos; Bogdanis, Gregory C.
2014-01-01
This study examined the effects of baseline flexibility and vertical jump ability on straight leg raise range of motion (ROM) and counter-movement jump performance (CMJ) following different volumes of stretching and potentiating exercises. ROM and CMJ were measured after two different warm-up protocols involving static stretching and potentiating exercises. Three groups of elite athletes (10 male, 14 female artistic gymnasts and 10 female rhythmic gymnasts) varying greatly in ROM and CMJ, performed two warm-up routines. One warm-up included short (15 s) static stretching followed by 5 tuck jumps, while the other included long static stretching (30 s) followed by 3x5 tuck jumps. ROM and CMJ were measured before, during and for 12 min after the two warm-up routines. Three-way ANOVA showed large differences between the three groups in baseline ROM and CMJ performance. A type of warm-up x time interaction was found for both ROM (p = 0.031) and CMJ (p = 0.016). However, all athletes, irrespective of group, responded in a similar fashion to the different warm-up protocols for both ROM and CMJ, as indicated from the lack of significant interactions for group (condition x group, time x group or condition x time x group). In the short warm-up protocol, ROM was not affected by stretching, while in the long warm-up protocol ROM increased by 5.9% ± 0.7% (p = 0.001) after stretching. Similarly, CMJ remained unchanged after the short warm-up protocol, but increased by 4.6 ± 0.9% (p = 0.012) 4 min after the long warm- up protocol, despite the increased ROM. It is concluded that the initial levels of flexibility and CMJ performance do not alter the responses of elite gymnasts to warm-up protocols differing in stretching and potentiating exercise volumes. Furthermore, 3 sets of 5 tuck jumps result in a relatively large increase in CMJ performance despite an increase in flexibility in these highly-trained athletes. Key Points The initial levels of flexibility and vertical jump ability have no effect on straight leg raise range of motion (ROM) and counter-movement jump performance (CMJ) of elite gymnasts following warm-up protocols differing in stretching and potentiating exercise volumes Stretching of the main leg muscle groups for only 15 s has no effect on ROM of elite gymnasts In these highly-trained athletes, one set of 5 tuck jumps during warm-up is not adequate to increase CMJ performance, while 3 sets of 5 tuck jumps result in a relatively large increase in CMJ performance (by 4.6% above baseline), despite a 5.9% increase in flexibility due to the 30 s stretching exercises PMID:24570613
[Three-dimensional reconstruction of functional brain images].
Inoue, M; Shoji, K; Kojima, H; Hirano, S; Naito, Y; Honjo, I
1999-08-01
We consider PET (positron emission tomography) measurement with SPM (Statistical Parametric Mapping) analysis to be one of the most useful methods to identify activated areas of the brain involved in language processing. SPM is an effective analytical method that detects markedly activated areas over the whole brain. However, with the conventional presentations of these functional brain images, such as horizontal slices, three directional projection, or brain surface coloring, makes understanding and interpreting the positional relationships among various brain areas difficult. Therefore, we developed three-dimensionally reconstructed images from these functional brain images to improve the interpretation. The subjects were 12 normal volunteers. The following three types of images were constructed: 1) routine images by SPM, 2) three-dimensional static images, and 3) three-dimensional dynamic images, after PET images were analyzed by SPM during daily dialog listening. The creation of images of both the three-dimensional static and dynamic types employed the volume rendering method by VTK (The Visualization Toolkit). Since the functional brain images did not include original brain images, we synthesized SPM and MRI brain images by self-made C++ programs. The three-dimensional dynamic images were made by sequencing static images with available software. Images of both the three-dimensional static and dynamic types were processed by a personal computer system. Our newly created images showed clearer positional relationships among activated brain areas compared to the conventional method. To date, functional brain images have been employed in fields such as neurology or neurosurgery, however, these images may be useful even in the field of otorhinolaryngology, to assess hearing and speech. Exact three-dimensional images based on functional brain images are important for exact and intuitive interpretation, and may lead to new developments in brain science. Currently, the surface model is the most common method of three-dimensional display. However, the volume rendering method may be more effective for imaging regions such as the brain.
NASA Technical Reports Server (NTRS)
Miller, Chris; Mulavara, Ajitkumar; Bloomberg, Jacob
2001-01-01
To confidently report any data collected from a video-based motion capture system, its functional characteristics must be determined, namely accuracy, repeatability and resolution. Many researchers have examined these characteristics with motion capture systems, but they used only two cameras, positioned 90 degrees to each other. Everaert used 4 cameras, but all were aligned along major axes (two in x, one in y and z). Richards compared the characteristics of different commercially available systems set-up in practical configurations, but all cameras viewed a single calibration volume. The purpose of this study was to determine the accuracy, repeatability and resolution of a 6-camera Motion Analysis system in a split-volume configuration using a quasistatic methodology.
1982-02-25
source both liquid and solid fuel combustion devices have been successfully demonstrated during various development programs . Nuclear reactor heat...U02 fuel in the core . Improving the heat pipe model to correlate more closely with the experimental data is a major concern in the development of...ORGANIZATION NAME AND ADDRESS 10. PROGRAM ELEMENT, PROJECT. TASK Research & Development Associates (RDA) AREA &WKNT AE (X Rosslyn, VA 22209 61102F 2301
1991-07-01
The prime mover for the MWP-2000 is a single steam powered jet venturi scrubber that was manufactured by Hydrosonics, Inc. to develop a negative...orime mover for the MWP-2000 is a single steam powered jet venturi scrubber that was manufactured by Hydrosonics, inc. to develop a negative pressure...packed tower and the scrubber during the trial burn or opening of the TRV, you should include these AWISOs since these shut offs would normally be
Prolonged partial cardiopulmonary bypass in rats.
Alexander, B; Al Ani, H R
1983-07-01
Membrane oxygenators have been shown to be atraumatic during cardiopulmonary bypass. A novel design for a membrane tubing oxygenator originated in this laboratory was used for prolonged partial supportive cardiopulmonary bypass in lambs and displayed excellent biocompatability characteristics. This was miniaturized, to result in a prime volume of 12 ml, in order to investigate the feasibility of prolonged partial supportive cardiopulmonary bypass in rats. The performance of this miniaturized circuit over perfusion periods up to 6 hr is described, with particular reference to hematological changes.
Perturbation Solutions for Variable Energy Blast Waves.
1976-08-01
SUPPLEMENTARY NOTES The findings in this report are not to be construed as an official Department of the Army position, unless so designated by other...over that of the same volume of undisturbed gas is Converting to non-dimensional form, using Equation (2.12) and letting a prime designate D/3m... designating the integral J after Sakurai1 this becomes Ea J . — - b p0R a+l y (2.20) If the total energy behind the shock varies as a
1980-01-01
2624. * ROCKET CENTER "Vg4o6 IN SCIENCE APPLICATIONS- INC 46.97 N4UNTSVILLF ALAMaM 6,736 6 9 mEMO!’ coos 33,4676 4 VUDIA A0170NA Is* 0 LOS1 ANGILTS...CORP Of AMERICA S 1.622 4 NAHUA 4 1,236 * CAN@RROGf NASS 19622 251 SUER, MARINE SVVTEMS 2.130 - . 27 AUSTIN PESEARCk ASSOCIATES 5 los1 ?* eHARLOTTESVILL
2004-04-01
Chinese-dominated Democratic Action Party ( DAP ). The BA was a marriage of convenience—a strategic pact—to avoid splitting votes in Malaysia’s plurality... Ibrahim , whom Mahathir had fired as deputy prime minister on charges of corruption and sexual misdemeanors, leading to a seri- ous political showdown...long-standing opposition parties, the Islamist PAS and the Chinese-dominated DAP , had formed an electoral understanding in the 1980s to challenge the
1993-10-01
development (exploratory, advanced, engineering, operational systems, or management and support services). Full definitions for each of these categories are ...displays the order of ranking for each, and shows how each has been categorized for reporting purposes. The categories are business firm (B...small businesses are further identified by an "S." The net value of awards to each of the firm’s reported locations is also provided. Tables 3, 4, and
MAIL LOG, program theory, volume 1. [Scout project automatic data system
NASA Technical Reports Server (NTRS)
Harris, D. K.
1979-01-01
The program theory used to obtain the software package, MAIL LOG, developed for the Scout Project Automatic Data System, SPADS, is described. The program is written in FORTRAN for the PRIME 300 computer system. The MAIL LOG data base consists of three main subfiles: (1) incoming and outgoing mail correspondence; (2) design information releases and reports; and (3) drawings and engineering orders. All subroutine descriptions, flowcharts, and MAIL LOG outputs are given and the data base design is described.
Electronically steerable millimeter wave antenna techniques for space shuttle applications
NASA Technical Reports Server (NTRS)
Kummer, W. H.
1975-01-01
A large multi-function antenna aperture and related components are described which will perform electronic steering of one or more beams for two of the three applications envisioned: (1) communications, (2) radar, and (3) radiometry. The array consists of a 6-meter folded antenna that fits into two pallets. The communications frequencies are 20 and 30 GHz, while the radar is to operate at 13.9 GHz. Weight, prime power, and volumes are given parametrically; antenna designs, electronics configurations, and mechanical design were studied.
Aerospace Structures Technology Damping Design Guide. Volume 2. Design Guide
1985-12-01
pickups, and antenna. 6-51 6.2.7.3 Typical response spectra for undamped antenna. 6-51 6.2.7.4 Damping properties of panacrit-BJ with 25 PHR carbon . 6-54...Temperature and dynamic characteristics are the two prime factors which must be reticulously measured to obtain good d&Aping design results. 4-20 WITHOU’T...The material finally chosen was Panacril-BJ with 25 PIUR super abrasive furnace carbon black added for strength. Without the added carbon the material
Air Force Civil Engineer, Volume 16, Number 2, 2008
2008-01-01
HORSE and Prime BEEF work together to put up a legal complex for JTF Guantanamo 11 Building Information Modeling in the Air Force Going beyond CADD 14...construction team. Engineers from the 823rd RED HORSE Squadron, Hurlburt Field, Fla., were responsible for most of the design work. The 474th...BEEF construction team and a RED HORSE design team, we quickly became known as the “Red Bulls.” The advance party — consisting of the first sergeant
A compilation and analysis of helicopter handling qualities data. Volume 1: Data compilation
NASA Technical Reports Server (NTRS)
Heffley, R. K.; Jewell, W. F.; Lehman, J. M.; Vanwinkle, R. A.
1979-01-01
A collection of basic descriptive data, stability derivatives and transfer functions for six degrees of freedom, quasi-static model is introduced. The data are arranged in a common, compact format for each of the five helicopters represented. The vehicles studied include the BO-105, AH-1h, and the CH53D.
AGARD Flight Test Techniques Series. Volume 2. Identification of Dynamic Systems
1985-01-01
should not depend upon it to solve the problem autonomously. The analyst’s strong point is in formulating the problem; the computer’s strength is in...of derivation for the output-error method is to reduce the problem to the static form of Chapter 5. We will see that the dinamic system make- the
NASA Technical Reports Server (NTRS)
Power, Gloria B.; Violett, Rebeca S.
1989-01-01
The analysis performed on the High Pressure Oxidizer Turbopump (HPOTP) preburner pump bearing assembly located on the Space Shuttle Main Engine (SSME) is summarized. An ANSYS finite element model for the inlet assembly was built and executed. Thermal and static analyses were performed.
A materials test system for static compression at elevated temperatures
NASA Astrophysics Data System (ADS)
Korellis, J. S.; Steinhaus, C. A.; Totten, J. J.
1992-06-01
This report documents modifications to our existing computer-controlled compression testing system to allow elevated temperature testing in an evacuated environment. We have adopted an 'inverse' design configuration where the evacuated test volume is located within the induction heating coil, eliminating the expense and minimizing the evacuation time of a much larger traditional vacuum chamber.
Lessons from the Past and Directions for the Future
ERIC Educational Resources Information Center
Xu, Yonghong Jade
2012-01-01
There is a steady line of research to understand faculty diversity and its impact on the work life quality of faculty and learning outcomes of students in the U.S. higher education systems. What makes this volume unique is that, rather than treating diversity as a static and simplistic concept, the chapter authors presented information to show…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ashley, G.W.; Harris, G.; Stubbe, J.
1988-10-04
The ribonucleoside triphosphate reductase of Lactobacillus leichmannii converts the substrate analogue 2{prime}-chloro-2{prime}-deoxyuridine 5{prime}-triphosphate (C1UTP) into a mixture of 2{prime}-deoxyuridine triphosphate (dUTP) and the unstable product 3{prime}-keto-2{prime}-deoxyuridine triphosphate (3{prime}-keto-dUTP). This ketone can be trapped by reduction with NaBH{sub 4}, producing a 4:1 mixture of xylo-dUTP and dUTP. When (3{prime}-{sup 3}H)C1UTP is treated with enzyme in the presence of NaBH{sub 4}, the isomeric deoxyuridines isolated after alkaline phosphatase treatment retained 15% of the {sup 3}H in C1UTP. Degradation of these isomeric nucleosides has established the location of the {sup 3}H in 3{prime}-keto-dUTP as predominantly 2{prime}(S). The xylo-dU had 98.6% of its labelmore » at the 2{prime}(S) position and 1.5% at 2{prime}(R). The isolated dU had 89.6% of its label at 2{prime}(S) and 1.4% at 2{prime}(R), with the remaining 9% label inferred to be at the 3{prime}-carbon, this resulting from the direct enzymic production of dUTP. These results are consistent with enzymic production of a 1:1,000 mixture of dUTP and 3{prime}-keto-dUTP, where the 3{prime}-hydrogen of C1UTP is retained at 3{prime} during production of dUTP and is transferred to 2{prime}(S) during production of 3{prime}-keto-dUTP. The implications of these results and the unique role of the cofactor adenosylcobalamin are discussed in terms of reductase being a model for the B{sub 12}-dependent rearrangement reactions.« less
Associative and repetition priming with the repeated masked prime technique: no priming found.
Avons, S E; Russo, Riccardo; Cinel, Caterina; Verolini, Veronica; Glynn, Kevin; McDonald, Rebecca; Cameron, Marie
2009-01-01
Wentura and Frings (2005) reported evidence of subliminal categorical priming on a lexical decision task, using a new method of visual masking in which the prime string consisted of the prime word flanked by random consonants and random letter masks alternated with the prime string on successive refresh cycles. We investigated associative and repetition priming on lexical decision, using the same method of visual masking. Three experiments failed to show any evidence of associative priming, (1) when the prime string was fixed at 10 characters (three to six flanking letters) and (2) when the number of flanking letters were reduced or absent. In all cases, prime detection was at chance level. Strong associative priming was observed with visible unmasked primes, but the addition of flanking letters restricted priming even though prime detection was still high. With repetition priming, no priming effects were found with the repeated masked technique, and prime detection was poor but just above chance levels. We conclude that with repeated masked primes, there is effective visual masking but that associative priming and repetition priming do not occur with experiment-unique prime-target pairs. Explanations for this apparent discrepancy across priming paradigms are discussed. The priming stimuli and prime-target pairs used in this study may be downloaded as supplemental materials from mc.psychonomic-journals.org/content/supplemental.
Program Helps To Determine Chemical-Reaction Mechanisms
NASA Technical Reports Server (NTRS)
Bittker, D. A.; Radhakrishnan, K.
1995-01-01
General Chemical Kinetics and Sensitivity Analysis (LSENS) computer code developed for use in solving complex, homogeneous, gas-phase, chemical-kinetics problems. Provides for efficient and accurate chemical-kinetics computations and provides for sensitivity analysis for variety of problems, including problems involving honisothermal conditions. Incorporates mathematical models for static system, steady one-dimensional inviscid flow, reaction behind incident shock wave (with boundary-layer correction), and perfectly stirred reactor. Computations of equilibrium properties performed for following assigned states: enthalpy and pressure, temperature and pressure, internal energy and volume, and temperature and volume. Written in FORTRAN 77 with exception of NAMELIST extensions used for input.
NASA Technical Reports Server (NTRS)
Wilson, D. J.
1972-01-01
Research was carried out to determine whether an oxide dispersion hardened alloy, TD-Ni, Cr, and low volume fraction gamma prime strengthened nickel-base alloy, Modified Waspaloy, were susceptible to time-dependent edge-notch sensitivity. The results were evaluated in terms of the mechanical characteristics of the alloys and the dislocation motion mechanisms operative. As far as could be determined, the results of the investigation were consistent with the following important concepts developed for Waspaloy and Inconel 718: (1) Time-dependent edge-notch sensitivity occurs when notched specimens are loaded below the approximate 0.2 percent smooth specimen offset yield strength and when data from smooth specimens indicate that small amounts of creep consume large rupture life fractions. (2) When precipitate particles are sheared by dislocations, the deformation is localized and time-dependent notch sensitivity occurs. When dislocations by-pass precipitate particles the deformation is homogeneous. Under these conditions, no time-dependent notch sensitivity has been observed.
Resonance dependence of gravitropicreactionof cress roots in weak combined magnetic fields.
NASA Astrophysics Data System (ADS)
Bogatina, N. I.; Sheykina, N. V.; Kordyum, E. L.
The gravitropic reaction of cress was studied in combined magnetic fields, that is the static magnetic field of the order of Earth's one and parallel to it alternating magnetic field. The frequency region for alternating magnetic field was varied in wide diapason ( from 1 Hz up to 45 Hz). The magnitude of alternating magnetic field was equal to 6 microT. The magnetic field conditions were well reproducible. For this purpose the external magnetic field was shielded in the work volume and artificial magnetic field was created in the volume. Both ferromagnetic metal shield and superconductive one with warm volume for work were used. The magnetic noises inside both of ferromagnetic metal and superconductive shields were measured to provide the well reproducible characteristics of artificial field created in the work volume. The objects of investigation were the roots of cress after 2-3-days germination. They were located in the closed humid room, that was located inside the shield in the artificially created magnetic field. All roots were in the darkness. For control we used the analogous roots located in the analogous volume but only in the static magnetic field of the Earth. We measured the divergence angle of the root from its primary direction of growing. We obtained the following results. The curve of dependence of measured angles on the frequency of alternating component of magnetic field had series of sharp peaks. These peaks were well reproducible and their location depended on the magnitude of the static component of magnetic field. The frequency of peak location is in direct proportion with its magnitude. The analysis showed that the location of peaks coincided very well with the cyclotron frequencies of the following ions: Ca+2, Cu+1 , K+1: Fe+3: Ag+1: and with the cyclotron frequencies of ions of phytohormons such as ions of indolile-acetic acid, abscise acid and gibberellins. Some quantitive analogies between the gravitropic process and the effect of combined magnetic field are discussed at the molecular level. In particularly it was shown that in the gravity field the pressure difference between the upper and down parts of the root was of the order of the pressure difference created by the Lorenz force. The displacement of the point where the pressure approached the maximum value on membrane surface could lead to the changes in the ion transport direction and so to the changes of the gravitropic reaction direction. The possibilities of the method for the studying the gravitropic reaction were discussed.
Twinning and martensite in a 304 austenitic stainless steel
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shen, Yongfeng; Li, Xi; Sun, Xin
2012-08-30
The microstructure characteristics and deformation behavior of 304L stainless steel during tensile deformation at two different strain rates have been investigated by means of interrupted tensile tests, electron-backscatter-diffraction (EBSD) and transmission electron microscopy (TEM) techniques. The volume fractions of transformed martensite and deformation twins at different stages of the deformation process were measured using X-ray diffraction method and TEM observations. It is found that the volume fraction of martensite monotonically increases with increasing strain but decreases with increasing strain rate. On the other hand, the volume fraction of twins increases with increasing strain for strain level less than 57%. Beyondmore » that, the volume fraction of twins decreases with increasing strain. Careful TEM observations show that stacking faults (SFs) and twins preferentially occur before the nucleation of martensite. Meanwhile, both {var_epsilon}-martensite and {alpha}{prime}-martensite are observed in the deformation microstructures, indicating the co-existence of stress induced- transformation and strain-induced-transformation. We also discussed the effects of twinning and martensite transformation on work-hardening as well as the relationship between stacking faults, twinning and martensite transformation.« less
Cognate status and cross-script translation priming.
Voga, Madeleine; Grainger, Jonathan
2007-07-01
Greek-French bilinguals were tested in three masked priming experiments with Greek primes and French targets. Related primes were the translation equivalents of target words, morphologically related to targets, or phonologically related to targets. In Experiment 1, cognate translation equivalents (phonologically similar translations) showed facilitatory priming, relative to matched phonologically related primes, in conditions in which morphologically related primes showed no effect (50-msec prime exposure). Cross-language morphological priming emerged at longer prime exposure durations (66 msec), but cognate primes continued to generate more priming than did those in the morphological condition. In Experiments 2 and 3, the level of phonological overlap across translation equivalents was varied, and priming effects were measured against those for matched phonologically related primes and those in an unrelated prime condition. When measured against the unrelated baseline, cognate primes showed the typical advantage over noncognate primes. However, this cognate advantage disappeared when priming was measured against the phonologically related prime condition. The results are discussed in terms of how translation equivalents are represented in bilingual memory.
Creep Deformation of Allvac 718Plus
Hayes, Robert W.; Unocic, Raymond R.; Nasrollahzadeh, Maryam
2014-11-11
The creep deformation behavior of Allvac 718Plus was studied over the temperature range 650° to 732°C at initial applied stress levels ranging from 517 to 655 MPa. Over the entire experimental temperature stress regime this alloy exhibits Class M type creep behavior with all creep curves exhibiting a decelerating strain rate with strain or time throughout primary creep. However, unlike pure metals or simple solid solution alloys this gamma prime strengthened superalloy does not exhibit steady state creep. Rather, primary creep is instantly followed by a long duration of accelerating strain rate with strain or time. These creep characteristics aremore » common amongst the gamma prime strengthened superalloys. Allvac 718Plus also exhibits a very high temperature dependence of creep rate. Detailed TEM examination of the deformation structures of selected creep samples reveals dislocation mechanisms similar to those found in high volume fraction gamma prime strengthened superalloys. Strong evidence of microtwinning is found in several of the deformation structures. The presence of microtwinning may account for the strong temperature dependence of creep rate observed in this alloy. In addition, due to the presence of Nb and thus, grain boundary delta phase, matrix dislocation activity which is not present in non Nb bearing superalloys occurs in this alloy. The creep characteristics and dislocation mechanisms are presented and discussed in detail.« less
Multipoint vibrometry with dynamic and static holograms
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haist, T.; Lingel, C.; Osten, W.
2013-12-15
We report on two multipoint vibrometers with user-adjustable position of the measurement spots. Both systems are using holograms for beam deflection. The measurement is based on heterodyne interferometry with a frequency difference of 5 MHz between reference and object beam. One of the systems uses programmable positioning of the spots in the object volume but is limited concerning the light efficiency. The other system is based on static holograms in combination with mechanical adjustment of the measurement spots and does not have such a general efficiency restriction. Design considerations are given and we show measurement results for both systems. Inmore » addition, we analyze the sensitivity of the systems which is a major limitation compared to single point scanning systems.« less
NASA Technical Reports Server (NTRS)
Allen, E. C., Jr.; Eder, F. W.
1972-01-01
Experimental aerodynamic investigations have been made on a .0035 scale model North American Rockwell/General Dynamics version of the space shuttle in the NASA/MSFC 14 x 14 Inch Trisonic Wind Tunnel. Static stability and control data were obtained on the delta wing booster alone (B-20) and with the delta wing orbiter (134D) mounted in various positions on the booster. Six component aerodynamic force and moment data were recorded over an angle of attack range from -10 to 24 deg at 0 and 6 deg sideslip angles and from -10 to +10 deg sideslip at 0 deg angle of attack. Mach number ranged from 0.6 to 4.96.
The acoustical structure of highly porous open-cell foams
NASA Technical Reports Server (NTRS)
Lambert, R. F.
1982-01-01
This work concerns both the theoretical prediction and measurement of structural parameters in open-cell highly porous polyurethane foams. Of particular interest are the dynamic flow resistance, thermal time constant, and mass structure factor and their dependence on frequency and geometry of the cellular structure. The predictions of cell size parameters, static flow resistance, and heat transfer as accounted for by a Nusselt number are compared with measurement. Since the static flow resistance and inverse thermal time constant are interrelated via the 'mean' pore size parameter of Biot, only two independent measurements such as volume porosity and mean filament diameter are required to make the predictions for a given fluid condition. The agreements between this theory and nonacoustical experiments are excellent.
Castagna, O; Desruelle, A V; Blatteau, J E; Schmid, B; Dumoulin, G; Regnard, J
2015-12-01
Highly trained "combat swimmers" encounter physiological difficulties when performing missions in warm water. The aim of this study was to assess the respective roles of immersion and physical activity in perturbing fluid balance of military divers on duty in warm water. 12 trained divers performed 2 dives each (2 h, 3 m depth) in fresh water at 29 °C. Divers either remained Static or swam continuously (Fin) during the dive. In the Fin condition, oxygen consumption and heart rate were 2-fold greater than during the Static dive. Core and skin temperatures were also higher (Fin: 38.5±0.4 °C and 36.2±0.3 °C and Static: 37.2±0.3 °C and 34.3±0.3 °C; respectively p=0.0002 and p=0.0003). During the Fin dive, the average mass loss was 989 g (39% urine loss, 41% sweating and 20% insensible water loss and blood sampling); Static divers lost 720 g (84% urine loss, 2% sweating and 14% insensible water loss and blood sampling) (p=0.003). In the Fin condition, a greater decrease in total body mass and greater sweating occurred, without effects on circulating renin and aldosterone concentrations; diuresis was reduced, and plasma volume decreased more than in the Static condition. © Georg Thieme Verlag KG Stuttgart · New York.
Effects of space flight and mixing on bacterial growth in low volume cultures
NASA Technical Reports Server (NTRS)
Kacena, M. A.; Manfredi, B.; Todd, P.
1999-01-01
Previous investigations have shown that liquid suspension bacterial cultures grow to higher cell concentrations in spaceflight than on Earth. None of these studies included ground-control experiments designed to evaluate the fluid effects potentially responsible for the reported increases. Therefore, the emphasis of this research was to both confirm differences in final cell concentration between 1g and microgravity cultures, and to examine the effects of mixing as a partial explanation for this difference. Flight experiments were performed in the Fluid Processing Apparatus (FPA), aboard Space Shuttle Missions STS-63 and STS-69, with simultaneous 1g static and agitated controls. Additional static 1g, agitated, and clino-rotated controls were performed in 9-ml culture tubes. This research revealed that both E. coli and B. subtilis samples cultured in space flight grew to higher final cell densities (120-345% increase) than simultaneous static 1g controls. The final cell concentration of E. coli cells cultured under agitation was 43% higher than in static 1g cultures and was 102% higher with clino-rotation. However, for B. subtilis cultures grown while being agitated on a shaker or clino-rotated, the final cell concentrations were nearly identical to those of the simultaneous static 1g controls. Therefore, these data suggest that the unique fluid quiescence in the microgravity environment (lack of sedimentation, creating unique transfer of nutrients and waste products), was responsible for the enhanced bacterial proliferation reported in this and other studies.
Prosperini, Luca; Kouleridou, Anna; Petsas, Nikolaos; Leonardi, Laura; Tona, Francesca; Pantano, Patrizia; Pozzilli, Carlo
2011-05-15
The role of static posturography and magnetic resonance imaging (MRI) in identifying patients at high risk of falls was investigated. Relationships between static posturography measures and MRI metrics were also investigated. A total of 31 ambulatory MS patients (EDSS ranging from 2.0 to 5.0) with a predominant balance disorder were recruited. Each patient underwent a static posturography with a monoaxial platform and a conventional 1.5 T brain MRI scan. Measurements of T1-hypointense and T2-hyperintense lesion volumes (LVs), focusing on lesions selectively located at infratentorial levels, were performed by two operators unaware of clinical data. The self-reported number of falls in the previous 6 months was considered as the main outcome measure. Fourteen (45%) patients reported 1 or more falls over the past 6 months. When compared to non-faller patients, they had a higher EDSS score, poorer static standing balance, and greater brainstem and middle cerebellar peduncle (MCP) T2-LVs. A strength correlation between brainstem T2-LV and impaired static standing balance in an open eye condition was also found. In the multivariate analysis, the variables more strictly associated with recurrent falls were greater T2-LV at the MCP (beta: 6.2; p=0.01) and brainstem (beta: 5.8; p=0.001) levels, and a wider displacement of the body center of pressure in the closed eye condition (beta: 0.02; p=0.03). Our data suggests that the damage of specific infratentorial areas negatively affect the static standing balance and may predispose MS patients to accidental falls. These findings might contribute in selecting patients requiring a proper rehabilitation intervention program. Copyright © 2011 Elsevier B.V. All rights reserved.
Static Strength of Adhesively-bonded Woven Fabric Kenaf Composite Plates
NASA Astrophysics Data System (ADS)
Hilton, Ahmad; Lee, Sim Yee; Supar, Khairi
2017-06-01
Natural fibers are potentially used as reinforcing materials and combined with epoxy resin as matrix system to form a superior specific strength (or stiffness) materials known as composite materials. The advantages of implementing natural fibers such as kenaf fibers are renewable, less hazardous during fabrication and handling process; and relatively cheap compared to synthetic fibers. The aim of current work is to conduct a parametric study on static strength of adhesively bonded woven fabric kenaf composite plates. Fabrication of composite panels were conducted using hand lay-up techniques, with variation of stacking sequence, over-lap length, joint types and lay-up types as identified in testing series. Quasi-static testing was carried out using mechanical testing following code of practice. Load-displacement profiles were analyzed to study its structural response prior to ultimate failures. It was found that cross-ply lay-up demonstrates better static strength compared to quasi-isotropic lay-up counterparts due to larger volume of 0° plies exhibited in cross-ply lay-up. Consequently, larger overlap length gives better joining strength, as expected, however this promotes to weight penalty in the joining structure. Most samples showed failures within adhesive region known as cohesive failure modes, however, few sample demonstrated interface failure. Good correlations of parametric study were found and discussed in the respective section.
Universal structural parameter to quantitatively predict metallic glass properties
Ding, Jun; Cheng, Yong-Qiang; Sheng, Howard; ...
2016-12-12
Quantitatively correlating the amorphous structure in metallic glasses (MGs) with their physical properties has been a long-sought goal. Here we introduce flexibility volume' as a universal indicator, to bridge the structural state the MG is in with its properties, on both atomic and macroscopic levels. The flexibility volume combines static atomic volume with dynamics information via atomic vibrations that probe local configurational space and interaction between neighbouring atoms. We demonstrate that flexibility volume is a physically appropriate parameter that can quantitatively predict the shear modulus, which is at the heart of many key properties of MGs. Moreover, the new parametermore » correlates strongly with atomic packing topology, and also with the activation energy for thermally activated relaxation and the propensity for stress-driven shear transformations. These correlations are expected to be robust across a very wide range of MG compositions, processing conditions and length scales.« less
NASA Astrophysics Data System (ADS)
Fathy, Naglaa; Ramadan, Mohamed
2018-05-01
The influence of volume ratio of liquid to Solid and low pouring temperature on interface structure of cast Babbitt-steel bimetal composite was evaluated for static casting technique. At low pouring temperature of 380 °C, Babbitt microstructures are improved to be finer and more globular. On the other side pouring the Babbitt at low pouring temperature of 380 °C increases the chance of present higher unbonded area percent. Increasing the volume ratio of liquid to solid decreases the Sn-Pb interface thicknesses and increases the bonded interface area. In order to optimize the production of Babbitt-steel bimetal composite at low pouring temperature, the volume ratio of liquid Babbitt to solid steel shell should be higher value that could be more than 5 depending on the extrapolation of current data presented.
Spirometry, Static Lung Volumes, and Diffusing Capacity.
Vaz Fragoso, Carlos A; Cain, Hilary C; Casaburi, Richard; Lee, Patty J; Iannone, Lynne; Leo-Summers, Linda S; Van Ness, Peter H
2017-09-01
Spirometric Z-scores from the Global Lung Initiative (GLI) rigorously account for age-related changes in lung function and are thus age-appropriate when establishing spirometric impairments, including a restrictive pattern and air-flow obstruction. However, GLI-defined spirometric impairments have not yet been evaluated regarding associations with static lung volumes (total lung capacity [TLC], functional residual capacity [FRC], and residual volume [RV]) and gas exchange (diffusing capacity). We performed a retrospective review of pulmonary function tests in subjects ≥40 y old (mean age 64.6 y), including pre-bronchodilator measures for: spirometry ( n = 2,586), static lung volumes by helium dilution with inspiratory capacity maneuver ( n = 2,586), and hemoglobin-adjusted single-breath diffusing capacity ( n = 2,508). Using multivariable linear regression, adjusted least-squares means (adj LS Means) were calculated for TLC, FRC, RV, and hemoglobin-adjusted single-breath diffusing capacity. The adj LS Means were expressed with and without height-cubed standardization and stratified by GLI-defined spirometry, including normal ( n = 1,251), restrictive pattern ( n = 663), and air-flow obstruction (mild, [ n = 128]; moderate, [ n = 150]; and severe, [ n = 394]). Relative to normal spirometry, restrictive-pattern had lower adj LS Means for TLC, FRC, RV, and hemoglobin-adjusted single-breath diffusing capacity ( P ≤ .001). Conversely, relative to normal spirometry, mild, moderate, and severe air-flow obstruction had higher adj LS Means for FRC and RV ( P < .001). However, only mild and moderate air-flow obstruction had higher adj LS Means for TLC ( P < .001), while only moderate and severe air-flow obstruction had higher adj LS Means for RV/TLC ( P < .001) and lower adj LS Means for hemoglobin-adjusted single-breath diffusing capacity ( P < .001). Notably, TLC (calculated as FRC + inspiratory capacity) was not increased in severe air-flow obstruction ( P ≥ .11) because inspiratory capacity decreased with increasing air-flow obstruction ( P < .001), thus opposing the increased FRC ( P < .001). Finally, P values were similar whether adj LS Means were height-cubed standardized. A GLI-defined spirometric restrictive pattern is strongly associated with a restrictive ventilatory defect (decreased TLC, FRC, and RV), while GLI-defined spirometric air-flow obstruction is strongly associated with hyperinflation (increased FRC) and air trapping (increased RV and RV/TLC). Both spirometric impairments were strongly associated with impaired gas exchange (decreased hemoglobin-adjusted single-breath diffusing capacity). Copyright © 2017 by Daedalus Enterprises.
Gilbert, Ian; Nisoli, Cristiano; Schiffer, Peter
2016-07-01
Geometrical frustration is a condition that occurs when a material’s lattice geometry precludes minimizing the energy of all the interactions among pairs of neighbors simultaneously. Moreover, the simplest example is three antiferromagnetically coupled Ising spins, pointing up or down, on the corners of an equilateral triangle: It is also impossible to arrange the spins so that each pair is antiparallel. In more complex magnetic lattices, the frustrated state can arise from the combination of lattice geometry and the strength and sign of the interactions among the magnetic dipole moments.1 (See the article by Roderich Moessner and Art Ramirez, Physics Today,more » February 2006, page 24.) A wide variety of exotic and collective phenomena sometimes arises from the competing interactions. One prime example is spin liquids, materials in which the local atomic moments fluctuate down to the lowest accessible temperatures and never settle into a static ground-state configuration.« less
Inverse target- and cue-priming effects of masked stimuli.
Mattler, Uwe
2007-02-01
The processing of a visual target that follows a briefly presented prime stimulus can be facilitated if prime and target stimuli are similar. In contrast to these positive priming effects, inverse priming effects (or negative compatibility effects) have been found when a mask follows prime stimuli before the target stimulus is presented: Responses are facilitated after dissimilar primes. Previous studies on inverse priming effects examined target-priming effects, which arise when the prime and the target stimuli share features that are critical for the response decision. In contrast, 3 experiments of the present study demonstrate inverse priming effects in a nonmotor cue-priming paradigm. Inverse cue-priming effects exhibited time courses comparable to inverse target-priming effects. Results suggest that inverse priming effects do not arise from specific processes of the response system but follow from operations that are more general.
Pimenta, A F R; Valente, A; Pereira, J M C; Pereira, J C F; Filipe, H P; Mata, J L G; Colaço, R; Saramago, B; Serro, A P
2016-12-01
Currently, most in vitro drug release studies for ophthalmic applications are carried out in static sink conditions. Although this procedure is simple and useful to make comparative studies, it does not describe adequately the drug release kinetics in the eye, considering the small tear volume and flow rates found in vivo. In this work, a microfluidic cell was designed and used to mimic the continuous, volumetric flow rate of tear fluid and its low volume. The suitable operation of the cell, in terms of uniformity and symmetry of flux, was proved using a numerical model based in the Navier-Stokes and continuity equations. The release profile of a model system (a hydroxyethyl methacrylate-based hydrogel (HEMA/PVP) for soft contact lenses (SCLs) loaded with diclofenac) obtained with the microfluidic cell was compared with that obtained in static conditions, showing that the kinetics of release in dynamic conditions is slower. The application of the numerical model demonstrated that the designed cell can be used to simulate the drug release in the whole range of the human eye tear film volume and allowed to estimate the drug concentration in the volume of liquid in direct contact with the hydrogel. The knowledge of this concentration, which is significantly different from that measured in the experimental tests during the first hours of release, is critical to predict the toxicity of the drug release system and its in vivo efficacy. In conclusion, the use of the microfluidic cell in conjunction with the numerical model shall be a valuable tool to design and optimize new therapeutic drug-loaded SCLs.
NASA Technical Reports Server (NTRS)
Goldstein, A. S.; Zhu, G.; Morris, G. E.; Meszlenyi, R. K.; Mikos, A. G.; McIntire, L. V. (Principal Investigator)
1999-01-01
Poly(DL-lactic-co-glycolic acid) (PLGA) foams are an osteoconductive support that holds promise for the development of bone tissue in vitro and implantation into orthopedic defects. Because it is desirable that foams maintain their shape and size, we examined a variety of foams cultured in vitro with osteoblastic cells. Foams were prepared with different porosities and pore sizes by the method of solvent casting/porogen leaching using 80, 85, and 90 wt% NaCl sieved with particle sizes of 150-300 and 300-500 microm and characterized by mercury intrusion porosimetry. Foams seeded with cells were found to have volumes after 7 days in static culture that decreased with increasing porosity: the least porous exhibited no change in volume while the most porous foams decreased by 39 +/- 10%. In addition, a correlation was observed between decreasing foam volume after 7 days in culture and decreasing internal surface area of the foams prior to seeding. Furthermore, foams prepared with the 300-500 microm porogen had lower porosities, greater mean wall thicknesses between adjacent pores, and larger volumes after 7 days in culture than those prepared with the smaller porogen. Two culture conditions for maintaining cells, static and agitated (in a rotary vessel), were found to have similar influences on foam size, cell density, and osteoblastic function for 7 and 14 days in culture. Finally, we examined unseeded foams in aqueous solutions of pH 3.0, 5.0, and 7.4 and found no significant decrease in foam size with degradation. This study demonstrates that adherent osteoblastic cells may collapse very porous PLGA foams prepared by solvent casting/particulate leaching: a potentially undesirable property for repair of orthopedic defects.
Biomechanical CT Metrics Are Associated With Patient Outcomes in COPD
Bodduluri, Sandeep; Bhatt, Surya P; Hoffman, Eric A.; Newell, John D.; Martinez, Carlos H.; Dransfield, Mark T.; Han, Meilan K.; Reinhardt, Joseph M.
2017-01-01
Background Traditional metrics of lung disease such as those derived from spirometry and static single-volume CT images are used to explain respiratory morbidity in patients with chronic obstructive pulmonary disease (COPD), but are insufficient. We hypothesized that the mean Jacobian determinant, a measure of local lung expansion and contraction with respiration, would contribute independently to clinically relevant functional outcomes. Methods We applied image registration techniques to paired inspiratory-expiratory CT scans and derived the Jacobian determinant of the deformation field between the two lung volumes to map local volume change with respiration. We analyzed 490 participants with COPD with multivariable regression models to assess strengths of association between traditional CT metrics of disease and the Jacobian determinant with respiratory morbidity including dyspnea (mMRC), St Georges Respiratory Questionnaire (SGRQ) score, six-minute walk distance (6MWD), and the BODE index, as well as all-cause mortality. Results The Jacobian determinant was significantly associated with SGRQ (adjusted regression co-efficient β = −11.75,95%CI −21.6 to −1.7;p=0.020), and with 6MWD (β=321.15, 95%CI 134.1 to 508.1;p<0.001), independent of age, sex, race, body-mass-index, FEV1, smoking pack-years, CT emphysema, CT gas trapping, airway wall thickness, and CT scanner protocol. The mean Jacobian determinant was also independently associated with the BODE index (β= −0.41, 95%CI −0.80 to −0.02; p = 0.039), and mortality on follow-up (adjusted hazards ratio = 4.26, 95%CI = 0.93 to 19.23; p = 0.064). Conclusion Biomechanical metrics representing local lung expansion and contraction improve prediction of respiratory morbidity and mortality and offer additional prognostic information beyond traditional measures of lung function and static single-volume CT metrics. PMID:28044005
Development of a silicone hollow fiber membrane oxygenator for ECMO application.
Yamane, S; Ohashi, Y; Sueoka, A; Sato, K; Kuwana, J; Nosé, Y
1998-01-01
A new silicone hollow fiber membrane oxygenator for extracorporeal membrane oxygenation (ECMO) was developed using an ultrathin silicone hollow fiber, with a 300 microm outer diameter and a wall thickness of 50 microm. The hollow fibers were mechanically cross-wound on the flow distributor to achieve equal distribution of blood flow without changing the fiber shape. The housing, made of silicone coated acryl, was 236 mm long with an inner diameter of 60 mm. The surface area was 1.0 m2 for prototype 211, and 1.1 m2 for prototype 209. The silicone fiber length was 150 mm, and the silicone membrane packing density was 43% for prototype 211 and 36% for prototype 209. Prototype 211 has a priming volume of 208 ml, and prototype 209 has a priming volume of 228 ml. The prototype 211 oxygenator demonstrates a gas transfer rate of 120 +/- 5 ml/min (mean +/- SD) for O2 and 67 +/- 12 ml/min for CO2 under 2 L of blood flow and 4 L of O2 gas flow. Prototype 209 produced the same values. The blood side pressure drop was low compared with the silicone sheet oxygenator (Avecor, 1500ECMO). These results showed that this new oxygenator for ECMO had efficiency similar to the silicone sheet oxygenator that has a 50% larger surface area. These results suggest that the new generation oxygenator using an ultrathin silicone hollow fiber possesses sufficient gas transfer performance for long-term extracorporeal lung support.
Pearson, Frances E; O'Mahony, Conor; Moore, Anne C; Hill, Adrian V S
2015-06-22
There is an urgent need for improvements in vaccine delivery technologies. This is particularly pertinent for vaccination programmes within regions of limited resources, such as those required for adequate provision for disposal of used needles. Microneedles are micron-sized structures that penetrate the stratum corneum of the skin, creating temporary conduits for the needle-free delivery of drugs or vaccines. Here, we aimed to investigate immunity induced by the recombinant simian adenovirus-vectored vaccine ChAd63.ME-TRAP; currently undergoing clinical assessment as a candidate malaria vaccine, when delivered percutaneously by silicon microneedle arrays. In mice, we demonstrate that microneedle-mediated delivery of ChAd63.ME-TRAP induced similar numbers of transgene-specific CD8(+) T cells compared to intradermal (ID) administration with needle-and-syringe, following a single immunisation and after a ChAd63/MVA heterologous prime-boost schedule. When mice immunised with ChAd63/MVA were challenged with live Plasmodium berghei sporozoites, microneedle-mediated ChAd63.ME-TRAP priming demonstrated equivalent protective efficacy as did ID immunisation. Furthermore, responses following ChAd63/MVA immunisation correlated with a specific design parameter of the array used ('total array volume'). The level of transgene expression at the immunisation site and skin-draining lymph node (dLN) was also linked to total array volume. These findings have implications for defining silicon microneedle array design for use with live, vectored vaccines. Copyright © 2015 Elsevier Ltd. All rights reserved.
Transfusion-Free Cardiopulmonary Bypass in Jehovah’s Witness Patients Weighing Less Than 5 kg
Boettcher, Wolfgang; Merkle, Frank; Huebler, Michael; Koster, Andreas; Schulz, Fritz; Kopitz, Michael; Kuppe, Hermann; Lange, Peter; Hetzer, Roland
2005-01-01
Abstract: Performing cardiac surgery on pediatric Jehovah’s Witness patients is a great challenge for the surgical team and especially for the perfusionist. Jehovah’s Witnesses reject blood transfusions on the grounds of their literal interpretation of passages of the Bible. In accordance with this belief, Jehovah’s Witnesses feel that it is also forbidden to retransfuse autologous blood that has been separated from their own circulatory system. We report the use of cardiopulmonary bypass (CPB) during open-heart surgery in three infants with a body weight of 4.5 kg, 3.5 kg, and 3.1 kg, respectively, without transfusion of blood components. A small-volume CPB circuit with a priming volume of 200 mL, including the arterial line filter, was designed to decrease the degree of hemodilution. A dedicated pediatric heart lung machine console with remote pump heads and intensive blood conservation efforts allowed the operation without the use of donor blood. The CPB circuits were primed with crystalloid solution only. The procedures were performed in normothermia or in moderate hypothermia. Pre-CPB hemoglobin levels were 10.8 g/dL, 10.6 g/dL, and 8.5 g/dL. The hemoglobin concentrations measured during CPB ranged from 5.9 to 6.5 g/dL, 6.4 to 6.8 g/dL, and 5.5 to 5.9 g/dL, respectively. The patients did not receive any blood or blood products during their entire hospital stay. PMID:16350381
NASA Technical Reports Server (NTRS)
Visscher, J.; Bakker, C. G.; Schwartz, Alan W.
1990-01-01
The effect of a 3-prime-5-prime pyrophosphate-linked oligomer of pTp on oligomerizations of pdAp and of its 3-prime-5-prime, 3-prime-3-prime, and 5-prime-5-prime dimers was investigated, using HPLC to separate the reaction mixtures; peak detection was by absorbance monitoring at 254 nm. It was expected that the dimers would form stable complexes with the template, with the degree of stability depending upon the internal linkage of each dimer. It was found that, although the isomers differ substantially in their oligomerization behavior in the absence of template, the analog-template catalyzes the oligomerization to about the same extent in all three cases.
Investigating the use of small-diameter softwood as guardrail posts: static test results
David E. Kretschmann; Ron Faller; Jason Hascall; John Reid; Dean Sicking; John Rohde; Dick Shilts; Tim Nelson
2007-01-01
Round guardrail posts may provide an important value added option for small-diameter thinnings. Such posts require minimum processing and have been shown to have higher strength compared to the equivalent rectangular volume. The resulting value-added product may bring a higher return compared to lumber. The obstacles to immediate utilization of ponderosa pine and...
Army Communicator. Volume 35, Number 3, Fall 2010
2010-01-01
Self - Healing Waveform extends squad communications Edric Thompson 44 5th Signal Command Implementing new...exciting because the network self heals its fragmented connectivity by leveraging other squad radios us- ing the waveform, said Mr. Eric Wil- liams...R&D Self - healing Waveform Rodney Smith (left), and Ted Krainski of C4ISR OTM set up radios as static nodes, representing
Organic Thin Films for Photonics Applications. Volume 14
1997-01-01
progress of the polymer optical fiber (POF) and related photonics polymer for high-speed telecommunication is reviewed. The high-bandwidth perfluorinated ...silicon. In the waveguide spectrometry studies described above, ab- sorption was measured on slab waveguides where fabrication imperfections are... compound in scries I[//| and II|//| , we have determined in solution: - the ground-state dipole /{ using capacitive measurements - the static
1989-03-01
comparison between the two. Tyre self-excited vibration can be caused by lack of uniforuity and/or out-of-balance. The authors suggest that driving ... safety is best described by the ’Dynamic Load Factor’ which relates the ainimum rolling dynamic load to the static tyre load. Dynamic Load Factors are
Aerodynamic Characteristics of the AFFTC Noseboom Instrumentation Unit. Volume I.
1982-03-01
connect the unit to a noseboom. Chanoes required to accomodate the tio accelerometers within the flow-angle sensor housing cause tic NDIU to differ...changed the nitot-static probe frorn a T7osemount M1oCel 852V usecl on previous AFFTC NBIU’s to a Rosemount "todel 852G. This chanoe was done to allow
A task-difficulty artifact in subliminal priming.
Pratte, Michael S; Rouder, Jeffrey N
2009-08-01
Subliminal priming is said to occur when a subliminal prime influences the classification of a subsequent target. Most subliminal-priming claims are based on separate target- and prime-classification tasks. Because primes are intended to be subliminal, the prime-classification task is difficult, and the target-classification task is easy. To assess whether this task-difficulty difference accounts for previous claims of subliminal priming, we manipulated the ease of the prime-classification task by intermixing long-duration (visible) primes with short-duration (near liminal) ones. In Experiment 1, this strategy of intermixing long-duration primes raised classification of the short-duration ones. In Experiments 2 and 3, prime duration was lowered in such a way that prime classification was at chance in intermixed presentations. Under these conditions, we failed to observe any priming effects; hence, previous demonstrations of subliminal priming may simply have reflected a task-difficulty artifact.
TOPICAL REVIEW: Spatial localization in nuclear magnetic resonance spectroscopy
NASA Astrophysics Data System (ADS)
Keevil, Stephen F.
2006-08-01
The ability to select a discrete region within the body for signal acquisition is a fundamental requirement of in vivo NMR spectroscopy. Ideally, it should be possible to tailor the selected volume to coincide exactly with the lesion or tissue of interest, without loss of signal from within this volume or contamination with extraneous signals. Many techniques have been developed over the past 25 years employing a combination of RF coil properties, static magnetic field gradients and pulse sequence design in an attempt to meet these goals. This review presents a comprehensive survey of these techniques, their various advantages and disadvantages, and implications for clinical applications. Particular emphasis is placed on the reliability of the techniques in terms of signal loss, contamination and the effect of nuclear relaxation and J-coupling. The survey includes techniques based on RF coil and pulse design alone, those using static magnetic field gradients, and magnetic resonance spectroscopic imaging. Although there is an emphasis on techniques currently in widespread use (PRESS, STEAM, ISIS and MRSI), the review also includes earlier techniques, in order to provide historical context, and techniques that are promising for future use in clinical and biomedical applications.
A Microfluidic Interface for the Culture and Sampling of Adiponectin from Primary Adipocytes
Godwin, Leah A.; Brooks, Jessica C.; Hoepfner, Lauren D.; Wanders, Desiree; Judd, Robert L.; Easley, Christopher J.
2014-01-01
Secreted from adipose tissue, adiponectin is a vital endocrine hormone that acts in glucose metabolism, thereby establishing its crucial role in diabetes, obesity, and other metabolic disease states. Insulin exposure to primary adipocytes cultured in static conditions has been shown to stimulate adiponectin secretion. However, conventional, static methodology for culturing and stimulating adipocytes falls short of truly mimicking physiological environments. Along with decreases in experimental costs and sample volume, and increased temporal resolution, microfluidic platforms permit small-volume flowing cell culture systems, which more accurately represent the constant flow conditions through vasculature in vivo. Here, we have integrated a customized primary tissue culture reservoir into a passively operated microfluidic device made of polydimethylsiloxane (PDMS). Fabrication of the reservoir was accomplished through unique PDMS “landscaping” above sampling channels, with a design strategy targeted to primary adipocytes to overcome issues of positive cell buoyancy. This reservoir allowed three-dimensional culture of primary murine adipocytes, accurate control over stimulants via constant perfusion, and sampling of adipokine secretion during various treatments. As the first report of primary adipocyte culture and sampling within microfluidic systems, this work sets the stage for future studies in adipokine secretion dynamics. PMID:25423362
Investigation of energy dissipation due to contact angle hysteresis in capillary effect
NASA Astrophysics Data System (ADS)
Athukorallage, Bhagya; Iyer, Ram
2016-06-01
Capillary action or Capillarity is the ability of a liquid to flow in narrow spaces without the assistance of, and in opposition to, external forces like gravity. Three effects contribute to capillary action, namely, adhesion of the liquid to the walls of the confining solid; meniscus formation; and low Reynolds number fluid flow. We investigate the dissipation of energy during one cycle of capillary action, when the liquid volume inside a capillary tube first increases and subsequently decreases while assuming quasi-static motion. The quasi-static assumption allows us to focus on the wetting phenomenon of the solid wall by the liquid and the formation of the meniscus. It is well known that the motion of a liquid on an non-ideal surface involves the expenditure of energy due to contact angle hysteresis. In this paper, we derive the equations for the menisci and the flow rules for the change of the contact angles for a liquid column in a capillary tube at a constant temperature and volume by minimizing the Helmholtz free energy using calculus of variations. We describe the numerical solution of these equations and present results from computations for the case of a capillary tube with 1 mm diameter.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lui, E.; Moya, Monica L.
This study seeks to validate the reproducibility of previous bioprinting work at Lawrence Livermore National Laboratory (LLNL) on a new Aerotech motion controller system and to modify an existing bioink, fibrin, by adding varying percent volumes of hyaluronic acid (HA). Endothelial and fibroblast cells bioprinted in fibrin gels using the Aerotech system were confirmed to be more than 77 percent viable after one day, and all bioprinted samples retained sterility after one week of culture. To characterize cell behavior in fibrin with HA addition, static co-culture gels with varying percent volumes of HA were cultured in vitro for one week.more » Resulting confocal microscope images showed increased cell network formation in all concentrations of HA compared to the control (no HA), and rheological tests mimicking static gel compositions displayed positive correlations between gelation time, gel stiffness (G’), and hyaluronic acid concentration. Although the current data is insufficient to quantitatively associate HA concentration with the level of cell vascularization, future work will aim to develop a targeted HA concentration in fibrin for maximum cell network formation, to optimize the printing process parameters for this new bioink composition, and to analyze cell viability in bioprinted fibrin-HA structures.« less
A 4DCT imaging-based breathing lung model with relative hysteresis
Miyawaki, Shinjiro; Choi, Sanghun; Hoffman, Eric A.; Lin, Ching-Long
2016-01-01
To reproduce realistic airway motion and airflow, the authors developed a deforming lung computational fluid dynamics (CFD) model based on four-dimensional (4D, space and time) dynamic computed tomography (CT) images. A total of 13 time points within controlled tidal volume respiration were used to account for realistic and irregular lung motion in human volunteers. Because of the irregular motion of 4DCT-based airways, we identified an optimal interpolation method for airway surface deformation during respiration, and implemented a computational solid mechanics-based moving mesh algorithm to produce smooth deforming airway mesh. In addition, we developed physiologically realistic airflow boundary conditions for both models based on multiple images and a single image. Furthermore, we examined simplified models based on one or two dynamic or static images. By comparing these simplified models with the model based on 13 dynamic images, we investigated the effects of relative hysteresis of lung structure with respect to lung volume, lung deformation, and imaging methods, i.e., dynamic vs. static scans, on CFD-predicted pressure drop. The effect of imaging method on pressure drop was 24 percentage points due to the differences in airflow distribution and airway geometry. PMID:28260811
Modeling static and dynamic human cardiovascular responses to exercise.
Stremel, R W; Bernauer, E M; Harter, L W; Schultz, R A; Walters, R F
1975-08-01
A human performance model has been developed and described [9] which portrays the human circulatory, thermo regulatory and energy-exchange systems as an intercoupled set. In this model, steady state or static relationships are used to describe oxygen consumption and blood flow. For example, heart rate (HTRT) is calculated as a function of the oxygen and the thermo-regulatory requirements of each body compartment, using the steady state work values of cardiac output (CO, sum of all compartment blood flows) and stroke volume (SV, assumed maximal after 40% maximal oxygen consumption): HTRT=CO/SV. The steady state model has proven to be an acceptable first approximation, but the inclusion of transient characteristics are essential in describing the overall systems' adjustment to exercise stress. In the present study, the dynamic transient characteristics of heart rate, stroke volume and cardiac output were obtained from experiments utilizing step and sinusoidal forcing of work. The gain and phase relationships reveal a probable first order system with a six minute time constant, and are utilized to model the transient characteristics of these parameters. This approach leads to a more complex model but a more accurate representation of the physiology involved. The instrumentation and programming essential to these experiments are described.
A 4DCT imaging-based breathing lung model with relative hysteresis
NASA Astrophysics Data System (ADS)
Miyawaki, Shinjiro; Choi, Sanghun; Hoffman, Eric A.; Lin, Ching-Long
2016-12-01
To reproduce realistic airway motion and airflow, the authors developed a deforming lung computational fluid dynamics (CFD) model based on four-dimensional (4D, space and time) dynamic computed tomography (CT) images. A total of 13 time points within controlled tidal volume respiration were used to account for realistic and irregular lung motion in human volunteers. Because of the irregular motion of 4DCT-based airways, we identified an optimal interpolation method for airway surface deformation during respiration, and implemented a computational solid mechanics-based moving mesh algorithm to produce smooth deforming airway mesh. In addition, we developed physiologically realistic airflow boundary conditions for both models based on multiple images and a single image. Furthermore, we examined simplified models based on one or two dynamic or static images. By comparing these simplified models with the model based on 13 dynamic images, we investigated the effects of relative hysteresis of lung structure with respect to lung volume, lung deformation, and imaging methods, i.e., dynamic vs. static scans, on CFD-predicted pressure drop. The effect of imaging method on pressure drop was 24 percentage points due to the differences in airflow distribution and airway geometry.
Model implementation for dynamic computation of system cost
NASA Astrophysics Data System (ADS)
Levri, J.; Vaccari, D.
The Advanced Life Support (ALS) Program metric is the ratio of the equivalent system mass (ESM) of a mission based on International Space Station (ISS) technology to the ESM of that same mission based on ALS technology. ESM is a mission cost analog that converts the volume, power, cooling and crewtime requirements of a mission into mass units to compute an estimate of the life support system emplacement cost. Traditionally, ESM has been computed statically, using nominal values for system sizing. However, computation of ESM with static, nominal sizing estimates cannot capture the peak sizing requirements driven by system dynamics. In this paper, a dynamic model for a near-term Mars mission is described. The model is implemented in Matlab/Simulink' for the purpose of dynamically computing ESM. This paper provides a general overview of the crew, food, biomass, waste, water and air blocks in the Simulink' model. Dynamic simulations of the life support system track mass flow, volume and crewtime needs, as well as power and cooling requirement profiles. The mission's ESM is computed, based upon simulation responses. Ultimately, computed ESM values for various system architectures will feed into an optimization search (non-derivative) algorithm to predict parameter combinations that result in reduced objective function values.
An MR-based Model for Cardio-Respiratory Motion Compensation of Overlays in X-Ray Fluoroscopy
Fischer, Peter; Faranesh, Anthony; Pohl, Thomas; Maier, Andreas; Rogers, Toby; Ratnayaka, Kanishka; Lederman, Robert; Hornegger, Joachim
2017-01-01
In X-ray fluoroscopy, static overlays are used to visualize soft tissue. We propose a system for cardiac and respiratory motion compensation of these overlays. It consists of a 3-D motion model created from real-time MR imaging. Multiple sagittal slices are acquired and retrospectively stacked to consistent 3-D volumes. Slice stacking considers cardiac information derived from the ECG and respiratory information extracted from the images. Additionally, temporal smoothness of the stacking is enhanced. Motion is estimated from the MR volumes using deformable 3-D/3-D registration. The motion model itself is a linear direct correspondence model using the same surrogate signals as slice stacking. In X-ray fluoroscopy, only the surrogate signals need to be extracted to apply the motion model and animate the overlay in real time. For evaluation, points are manually annotated in oblique MR slices and in contrast-enhanced X-ray images. The 2-D Euclidean distance of these points is reduced from 3.85 mm to 2.75 mm in MR and from 3.0 mm to 1.8 mm in X-ray compared to the static baseline. Furthermore, the motion-compensated overlays are shown qualitatively as images and videos. PMID:28692969
First measurement of the neutron beta asymmetry with ultracold neutrons.
Pattie, R W; Anaya, J; Back, H O; Boissevain, J G; Bowles, T J; Broussard, L J; Carr, R; Clark, D J; Currie, S; Du, S; Filippone, B W; Geltenbort, P; García, A; Hawari, A; Hickerson, K P; Hill, R; Hino, M; Hoedl, S A; Hogan, G E; Holley, A T; Ito, T M; Kawai, T; Kirch, K; Kitagaki, S; Lamoreaux, S K; Liu, C-Y; Liu, J; Makela, M; Mammei, R R; Martin, J W; Melconian, D; Meier, N; Mendenhall, M P; Morris, C L; Mortensen, R; Pichlmaier, A; Pitt, M L; Plaster, B; Ramsey, J C; Rios, R; Sabourov, K; Sallaska, A L; Saunders, A; Schmid, R; Seestrom, S; Servicky, C; Sjue, S K L; Smith, D; Sondheim, W E; Tatar, E; Teasdale, W; Terai, C; Tipton, B; Utsuro, M; Vogelaar, R B; Wehring, B W; Xu, Y P; Young, A R; Yuan, J
2009-01-09
We report the first measurement of an angular correlation parameter in neutron beta decay using polarized ultracold neutrons (UCN). We utilize UCN with energies below about 200 neV, which we guide and store for approximately 30 s in a Cu decay volume. The interaction of the neutron magnetic dipole moment with a static 7 T field external to the decay volume provides a 420 neV potential energy barrier to the spin state parallel to the field, polarizing the UCN before they pass through an adiabatic fast passage spin flipper and enter a decay volume, situated within a 1 T field in a 2x2pi solenoidal spectrometer. We determine a value for the beta-asymmetry parameter A_{0}=-0.1138+/-0.0046+/-0.0021.
NASA Astrophysics Data System (ADS)
Singh, Manpreet; Das, Anindya; Venugopalan, T.; Mukherjee, Krishnendu; Walunj, Mahesh; Nanda, Tarun; Kumar, B. Ravi
2017-12-01
The effects of microstructure parameters of dual-phase steels on tensile high strain dynamic deformation characteristic were examined in this study. Cold-rolled steel sheets were annealed using three different annealing process parameters to obtain three different dual-phase microstructures of varied ferrite and martensite phase fraction. The volume fraction of martensite obtained in two of the steels was near identical ( 19 pct) with a subtle difference in its spatial distribution. In the first microstructure variant, martensite was mostly found to be situated at ferrite grain boundaries and in the second variant, in addition to at grain boundaries, in-grain martensite was also observed. The third microstructure was very different from the above two with respect to martensite volume fraction ( 67 pct) and its morphology. In this case, martensite packets were surrounded by a three-dimensional ferrite network giving an appearance of core and shell type microstructure. All the three steels were tensile deformed at strain rates ranging from 2.7 × 10-4 (quasi-static) to 650 s-1 (dynamic range). Field-emission scanning electron microscope was used to characterize the starting as well as post-tensile deformed microstructures. Dual-phase steel consisting of small martensite volume fraction ( 19 pct), irrespective of its spatial distribution, demonstrated high strain rate sensitivity and on the other hand, steel with large martensite volume fraction ( 67 pct) displayed a very little strain rate sensitivity. Interestingly, total elongation was found to increase with increasing strain rate in the dynamic regime for steel with core-shell type of microstructure containing large martensite volume fraction. The observed enhancement in plasticity in dynamic regime was attributed to adiabatic heating of specimen. To understand the evolving damage mechanism, the fracture surface and the vicinity of fracture ends were studied in all the three dual-phase steels.
NASA Astrophysics Data System (ADS)
Singh, Manpreet; Das, Anindya; Venugopalan, T.; Mukherjee, Krishnendu; Walunj, Mahesh; Nanda, Tarun; Kumar, B. Ravi
2018-02-01
The effects of microstructure parameters of dual-phase steels on tensile high strain dynamic deformation characteristic were examined in this study. Cold-rolled steel sheets were annealed using three different annealing process parameters to obtain three different dual-phase microstructures of varied ferrite and martensite phase fraction. The volume fraction of martensite obtained in two of the steels was near identical ( 19 pct) with a subtle difference in its spatial distribution. In the first microstructure variant, martensite was mostly found to be situated at ferrite grain boundaries and in the second variant, in addition to at grain boundaries, in-grain martensite was also observed. The third microstructure was very different from the above two with respect to martensite volume fraction ( 67 pct) and its morphology. In this case, martensite packets were surrounded by a three-dimensional ferrite network giving an appearance of core and shell type microstructure. All the three steels were tensile deformed at strain rates ranging from 2.7 × 10-4 (quasi-static) to 650 s-1 (dynamic range). Field-emission scanning electron microscope was used to characterize the starting as well as post-tensile deformed microstructures. Dual-phase steel consisting of small martensite volume fraction ( 19 pct), irrespective of its spatial distribution, demonstrated high strain rate sensitivity and on the other hand, steel with large martensite volume fraction ( 67 pct) displayed a very little strain rate sensitivity. Interestingly, total elongation was found to increase with increasing strain rate in the dynamic regime for steel with core-shell type of microstructure containing large martensite volume fraction. The observed enhancement in plasticity in dynamic regime was attributed to adiabatic heating of specimen. To understand the evolving damage mechanism, the fracture surface and the vicinity of fracture ends were studied in all the three dual-phase steels.
Masked priming effect reflects evidence accumulated by the prime.
Kinoshita, Sachiko; Norris, Dennis
2010-01-01
In the same-different match task, masked priming is observed with the same responses but not different responses. Norris and Kinoshita's (2008) Bayesian reader account of masked priming explains this pattern based on the same principle as that explaining the absence of priming for nonwords in the lexical decision task. The pattern of priming follows from the way the model makes optimal decisions in the two tasks; priming does not depend on first activating the prime and then the target. An alternative explanation is in terms of a bias towards responding "same" that exactly counters the facilitatory effect of lexical access. The present study tested these two views by varying both the degree to which the prime predicts the response and the visibility of the prime. Unmasked primes produced effects expected from the view that priming is influenced by the degree to which the prime predicts the response. In contrast, with masked primes, the size of priming for the same response was completely unaffected by predictability. These results rule out response bias as an explanation of the absence of masked priming for different responses and, in turn, indicate that masked priming is not a consequence of automatic lexical access of the prime.
Repetition priming effects from attended vs. ignored single words in a semantic categorization task.
Ortells, Juan J; Fox, Elaine; Noguera, Carmen; Abad, María J F
2003-10-01
The present research examines priming effects from a centrally presented single-prime word to which participants were instructed to either attend or ignore. The prime word was followed by a single central target word to which participants made a semantic categorization (animate vs. inanimate) task. The main variables manipulated across experiments were attentional instructions (attend vs. ignore the prime word), presentation duration of the prime word (20, 50, 80 or 100 ms), prime-target stimulus onset asynchrony (SOA; 300 vs. 800 ms), and temporal presentation of instructions (before vs. after the prime word). The results showed (a) a consistent interaction between attentional instructions and repetition priming and (b) a qualitatively different ignored priming pattern as a function of prime duration: reduced positive priming (relative to the attend instruction) for prime exposures of 80 and 100 ms, and reliable negative priming for the shorter prime exposures of 20 and 50 ms. In addition (c), the differential priming pattern for attend and ignore trials was observed at a prime-target SOA of 800 ms (but not at a shorter 300-ms SOA) and only when instructions were presented before the prime word. Methodological and theoretical implications of the present findings for the extant negative priming literature are discussed.
Effects of fluid shear stress on polyelectrolyte multilayers by neutron scattering studies
Singh, Saurabh; Junghans, Ann; Watkins, Erik; ...
2015-02-17
The structure of layer-by-layer (LbL) deposited nanofilm coatings consists of alternating polyethylenimine (PEI) and polystyrenesulfonate (PSS) films deposited on a single crystal quartz substrate. LbL-deposited nanofilms were investigated by neutron reflectomery (NR) in contact with water in the static and fluid shear stress conditions. The fluid shear stress was applied through a laminar flow of the liquid parallel to the quartz/polymer interface in a custom-built solid–liquid interface cell. The scattering length density profiles obtained from NR results of these polyelectrolyte multilayers (PEM), measured under different shear conditions, showed proportional decrease of volume fraction of water hydrating the polymers. For themore » highest shear rate applied (ca. 6800 s –1) the water volume fraction decreased by approximately 7%. The decrease of the volume fraction of water was homogeneous through the thickness of the film. Since there were not any significant changes in the total polymer thickness, it resulted in negative osmotic pressures in the film. The PEM films were compared with the behavior of thin films of thermoresponsive poly(N-isopropylacrylamide) (pNIPAM) deposited via spin-coating. The PEM and pNIPAM differ in their interactions with water molecules, and they showed opposite behaviors under the fluid shear stress. In both cases the polymer hydration was reversible upon the restoration of static conditions. Furthermore, a theoretical explanation is given to explain this difference in the effect of shear on hydration of polymeric thin films.« less
Compressive evaluation of homogeneous and graded epoxy-glass particulate composites.
Seaglar, J; Rousseau, C-E
2015-04-01
The propagation of stress waves in epoxy-glass particulate composites and graded materials was studied experimentally. Materials tested in this study consisted of an epoxy matrix with various concentrations of spherical glass particles having a mean diameter of 42μm. Plate impact experiments were performed using a gas gun. Embedded within the specimens were manganin stress gauges used to record propagating compressive longitudinal stress waves through the material. High strain rate experiments using a Split Hopkinson Pressure Bar (SHPB) apparatus were also performed to evaluate the dynamic strength of the specimens, while quasi-static compression tests were undertaken to characterize their quasi-static behavior. Ultrasonic wave speed measurements were carried-out in order to obtain additional material properties and characterize the gradation in functionally graded materials (FGM). It was found that low volume fractions of particles are detrimental to the performance of the material under impact loading, while concentrations in the range of about 30 to 45% by volume exhibit characteristics of higher degrees of scattering. This suggests that materials in this latter range would be more effective in the thwarting of destructive shock waves than the homogeneous matrix material. Impact testing of FGM specimens suggests that impact loading on the stiff (high volume fraction) face results in much higher levels of scattering. Therefore, such materials would be effective for use in light weight armor or as shielding materials due to their effective attenuation of mechanical impulses. Copyright © 2015 Elsevier B.V. All rights reserved.
Pseudolinear gradient ultrahigh-pressure liquid chromatography using an injection valve assembly.
Xiang, Yanqiao; Liu, Yansheng; Stearns, Stanley D; Plistil, Alex; Brisbin, Martin P; Lee, Milton L
2006-02-01
The use of ultrahigh pressures in liquid chromatography (UHPLC) imposes stringent requirements on hardware such as pumps, valves, injectors, connecting tubing, and columns. One of the most difficult components of the UHPLC system to develop has been the sample injector. Static-split injection, which can be performed at pressures up to 6900 bar (100,000 psi), consumes a large sample volume and is very irreproducible. A pressure-balanced injection valve provided better reproducibility, shorter injection time, reduced sample consumption, and greater ease of use; however, it could only withstand pressures up to approximately 1000 bar (15,000 psi). In this study, a new injection valve assembly that can operate at pressures as high as 2070 bar (30,000 psi) was evaluated for UHPLC. This assembly contains six miniature electronically controlled needle valves to provide accurate and precise volumes for introduction into the capillary LC column. It was found that sample volumes as small as several tenths of a nanoliter can be injected, which are comparable to the results obtained from the static-split injector. The reproducibilities of retention time, efficiency, and peak area were investigated, and the results showed that the relative standard deviations of these parameters were small enough for quantitative analyses. Separation experiments using the UHPLC system with this new injection valve assembly showed that this new injector is suitable for both isocratic and gradient operation modes. A newly designed capillary connector was used at a pressure as high as 2070 bar (30,000 psi).
Early dynamics of the semantic priming shift
Lavigne, Frédéric; Chanquoy, Lucile; Dumercy, Laurent; Vitu, Françoise
2013-01-01
Semantic processing of sequences of words requires the cognitive system to keep several word meanings simultaneously activated in working memory with limited capacity. The real- time updating of the sequence of word meanings relies on dynamic changes in the associates to the words that are activated. Protocols involving two sequential primes report a semantic priming shift from larger priming of associates to the first prime to larger priming of associates to the second prime, in a range of long SOAs (stimulus-onset asynchronies) between the second prime and the target. However, the possibility for an early semantic priming shift is still to be tested, and its dynamics as a function of association strength remain unknown. Three multiple priming experiments are proposed that cross-manipulate association strength between each of two successive primes and a target, for different values of short SOAs and prime durations. Results show an early priming shift ranging from priming of associates to the first prime only to priming of strong associates to the first prime and all of the associates to the second prime. We investigated the neural basis of the early priming shift by using a network model of spike frequency adaptive cortical neurons (e.g., Deco & Rolls, 2005), able to code different association strengths between the primes and the target. The cortical network model provides a description of the early dynamics of the priming shift in terms of pro-active and retro-active interferences within populations of excitatory neurons regulated by fast and unselective inhibitory feedback. PMID:23717346
Priming mortality salience: supraliminal, subliminal and "double-death" priming techniques.
Mahoney, Melissa B; Saunders, Benjamin A; Cain, Nicole M
2014-01-01
The study examined whether successively presented subliminal and supraliminal morality salience primes ("double death" prime) would have a stronger influence on death thought accessibility than subliminal or supraliminal primes alone. A between-subjects 2 (subliminal prime/control) × 2 (supraliminal prime/control) design was used. The supraliminal prime prompted participants to answer questions about death. For the subliminal prime, the word death was presented outside of awareness. Both priming techniques differed significantly from a control in ability to elicit mortality salience. There was an interactive influence of both primes. Implications for unconscious neutral networks relating to death are discussed.
Subliminal priming with nearly perfect performance in the prime-classification task.
Finkbeiner, Matthew
2011-05-01
The subliminal priming paradigm is widely used by cognitive scientists, and claims of subliminal perception are common nowadays. Nevertheless, there are still those who remain skeptical. In a recent critique of subliminal priming, Pratte and Rouder (Attention, Perception, & Psychophysics, 71, 1276-1283, 2009) suggested that previous claims of subliminal priming may have been due to a failure to control the task difficulty between the experiment proper and the prime-classification task. Essentially, because the prime-classification task is more difficult than the experiment proper, the prime-classification task results may underrepresent the subjects' true ability to perceive the prime stimuli. To address this possibility, prime words were here presented in color. In the experiment proper, priming was observed. In the prime-classification task, subjects reported the color of the primes very accurately, indicating almost perfect control of task difficulty, but they could not identify the primes. Thus, I conclude that controlling for task difficulty does not eliminate subliminal priming.
Scharlau, Ingrid
2002-11-01
Presenting a masked prime leading a target influences the perceived onset of the masking target (perceptual latency priming; Scharlau & Neumann, in press). This priming effect is explained by the asynchronous updating model (Neumann, 1982; Scharlau & Neumann, in press): The prime initiates attentional allocation toward its location, which renders a trailing target at the same place consciously available earlier. In three experiments, this perceptual latency priming by leading primes was examined jointly with the effects of trailing primes in order to compare the explanation of the asynchronous updating model with the onset-averaging and the P-center hypotheses. Experiment 1 showed that an attended, as well as an unattended, prime leads to perceptual latency priming. In addition, a large effect of trailing primes on the onset of a target was found. As Experiment 2 demonstrated, this effect is quite robust, although smaller than that of a leading prime. In Experiment 3, masked primes were used. Under these conditions, no influence of trailing primes could be found, whereas perceptual latency priming persisted. Thus, a nonattentional explanation for the effect of trailing primes seems likely.
Phonological and Orthographic Overlap Effects in Fast and Masked Priming
Frisson, Steven; Bélanger, Nathalie N.; Rayner, Keith
2014-01-01
We investigated how orthographic and phonological information is activated during reading, using a fast priming task, and during single word recognition, using masked priming. Specifically, different types of overlap between prime and target were contrasted: high orthographic and high phonological overlap (track-crack), high orthographic and low phonological overlap (bear-gear), or low orthographic and high phonological overlap (fruit-chute). In addition, we examined whether (orthographic) beginning overlap (swoop-swoon) yielded the same priming pattern as end (rhyme) overlap (track-crack). Prime durations were 32 and 50ms in the fast priming version, and 50ms in the masked priming version, and mode of presentation (prime and target in lower case) was identical. The fast priming experiment showed facilitatory priming effects when both orthography and phonology overlapped, with no apparent differences between beginning and end overlap pairs. Facilitation was also found when prime and target only overlapped orthographically. In contrast, the masked priming experiment showed inhibition for both types of end overlap pairs (with and without phonological overlap), and no difference for begin overlap items. When prime and target only shared principally phonological information, facilitation was only found with a long prime duration in the fast priming experiment, while no differences were found in the masked priming version. These contrasting results suggest that fast priming and masked priming do not necessarily tap into the same type of processing. PMID:24365065
Poisson's Ratio of a Hyperelastic Foam Under Quasi-static and Dynamic Loading
Sanborn, Brett; Song, Bo
2018-06-03
Poisson's ratio is a material constant representing compressibility of material volume. However, when soft, hyperelastic materials such as silicone foam are subjected to large deformation into densification, the Poisson's ratio may rather significantly change, which warrants careful consideration in modeling and simulation of impact/shock mitigation scenarios where foams are used as isolators. The evolution of Poisson's ratio of silicone foam materials has not yet been characterized, particularly under dynamic loading. In this study, radial and axial measurements of specimen strain are conducted simultaneously during quasi-static and dynamic compression tests to determine the Poisson's ratio of silicone foam. The Poisson's ratiomore » of silicone foam exhibited a transition from compressible to nearly incompressible at a threshold strain that coincided with the onset of densification in the material. Poisson's ratio as a function of engineering strain was different at quasi-static and dynamic rates. Here, the Poisson's ratio behavior is presented and can be used to improve constitutive modeling of silicone foams subjected to a broad range of mechanical loading.« less
Poisson's Ratio of a Hyperelastic Foam Under Quasi-static and Dynamic Loading
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sanborn, Brett; Song, Bo
Poisson's ratio is a material constant representing compressibility of material volume. However, when soft, hyperelastic materials such as silicone foam are subjected to large deformation into densification, the Poisson's ratio may rather significantly change, which warrants careful consideration in modeling and simulation of impact/shock mitigation scenarios where foams are used as isolators. The evolution of Poisson's ratio of silicone foam materials has not yet been characterized, particularly under dynamic loading. In this study, radial and axial measurements of specimen strain are conducted simultaneously during quasi-static and dynamic compression tests to determine the Poisson's ratio of silicone foam. The Poisson's ratiomore » of silicone foam exhibited a transition from compressible to nearly incompressible at a threshold strain that coincided with the onset of densification in the material. Poisson's ratio as a function of engineering strain was different at quasi-static and dynamic rates. Here, the Poisson's ratio behavior is presented and can be used to improve constitutive modeling of silicone foams subjected to a broad range of mechanical loading.« less
Aeroelastic Deformation Measurements of Flap, Gap, and Overhang on a Semispan Model
NASA Technical Reports Server (NTRS)
Burner, A. W.; Liu, Tian-Shu; Garg, Sanjay; Ghee, Terence A.; Taylor, Nigel J.
2001-01-01
Single-camera, single-view videogrammetry has been used for the first time to determine static aeroelastic deformation of a slotted flap configuration on a semispan model at the National Transonic Facility (NTF). Deformation was determined by comparing wind-off to wind-on spatial data from targets placed on the main element, shroud, and flap of the model. Digitized video images from a camera were recorded and processed to automatically determine target image plane locations that were then corrected for sensor, lens, and frame grabber spatial errors. The videogrammetric technique used for the measurements presented here has been established at NASA facilities as the technique of choice when high-volume static aeroelastic data with minimum impact on data taking is required. However, the primary measurement at the NTF with this technique in the past has been the measurement of the static aeroelastic wing twist of the main wing element on full span models rather than for the measurement of component deformation. Considerations for using the videogrammetric technique for semispan component deformation measurements as well as representative results are presented.
Fontán-Sainz, María; Gómez-Couso, Hipólito; Fernández-Ibáñez, Pilar; Ares-Mazás, Elvira
2012-01-01
Water samples of 0, 5, and 30 nephelometric turbidity units (NTU) spiked with Cryptosporidium parvum oocysts were exposed to natural sunlight using a 25-L static solar reactor fitted with a compound parabolic collector (CPC). The global oocyst viability was calculated by the evaluation of the inclusion/exclusion of the fluorogenic vital dye propidium iodide and the spontaneous excystation. After an exposure time of 8 hours, the global oocyst viabilities were 21.8 ± 3.1%, 31.3 ± 12.9%, and 45.0 ± 10.0% for turbidity levels of 0, 5, and 30 NTU, respectively, and these values were significantly lower (P < 0.05) that the initial global viability of the isolate (92.1 ± 0.9%). The 25-L static solar reactor that was evaluated can be an alternative system to the conventional solar water disinfection process for improving the microbiological quality of drinking water on a household level, and moreover, it enables treatment of larger volumes of water (> 10 times). PMID:22302852
Fontán-Sainz, María; Gómez-Couso, Hipólito; Fernández-Ibáñez, Pilar; Ares-Mazás, Elvira
2012-02-01
Water samples of 0, 5, and 30 nephelometric turbidity units (NTU) spiked with Cryptosporidium parvum oocysts were exposed to natural sunlight using a 25-L static solar reactor fitted with a compound parabolic collector (CPC). The global oocyst viability was calculated by the evaluation of the inclusion/exclusion of the fluorogenic vital dye propidium iodide and the spontaneous excystation. After an exposure time of 8 hours, the global oocyst viabilities were 21.8 ± 3.1%, 31.3 ± 12.9%, and 45.0 ± 10.0% for turbidity levels of 0, 5, and 30 NTU, respectively, and these values were significantly lower (P < 0.05) that the initial global viability of the isolate (92.1 ± 0.9%). The 25-L static solar reactor that was evaluated can be an alternative system to the conventional solar water disinfection process for improving the microbiological quality of drinking water on a household level, and moreover, it enables treatment of larger volumes of water (> 10 times).
ELECTRIC IMPEDANCE OF HIPPONOË EGGS
Cole, Kenneth S.
1935-01-01
Alternating current resistance and capacity measurements have been made from 1.08 103 to 2.32 106 cycles per second on suspensions of unfertilized, fertilized, and swollen unfertilized eggs of the echinoderm Hipponoë esculenta. A simple method has been developed for measuring the volume concentration of eggs in a suspension. The membrane of the unfertilized egg is practically non-conducting at low frequencies and shows a static capacity of 0.87 µf/cm.2 except perhaps at the highest frequencies. The equivalent specific resistance of the egg interior is 11 times that of sea water. The membrane of the fertilized egg is practically non-conducting at low frequencies and shows a static capacity 2.5 times that of the unfertilized egg except at the higher frequencies where another reactive element produces a marked effect. The internal resistance is apparently higher than that of the unfertilized egg. The static capacity per unit area of the membrane decreases as a linear function of the surface area when the eggs are swollen in dilute sea water. In 40 per cent sea water, the capacity falls to about 75 per cent of normal. PMID:19872897
Olsson, Pontus; Nysjo, Fredrik; Carlbom, Ingrid B; Johansson, Stefan
2016-01-01
Piezoelectric motors offer an attractive alternative to electromagnetic actuators in portable haptic interfaces: they are compact, have a high force-to-volume ratio, and can operate with limited or no gearing. However, the choice of a piezoelectric motor type is not obvious due to differences in performance characteristics. We present our evaluation of two commercial, operationally different, piezoelectric motors acting as actuators in two kinesthetic haptic grippers, a walking quasi-static motor and a traveling wave ultrasonic motor. We evaluate each gripper's ability to display common virtual objects including springs, dampers, and rigid walls, and conclude that the walking quasi-static motor is superior at low velocities. However, for applications where high velocity is required, traveling wave ultrasonic motors are a better option.
Design integration and noise studies for jet STOL aircraft. Volume 1: Program summary
NASA Technical Reports Server (NTRS)
Okeefe, V. O.; Kelley, G. S.
1972-01-01
This program was undertaken to develop, through analysis, design, experimental static testing, wind tunnel testing, and design integration studies, an augmentor wing jet flap configuration for a jet STOL transport aircraft having maximum propulsion and aerodynamic performance with minimum noise generation. The program had three basic elements: (1) static testing of a scale wing section to demonstrate augmentor performance and noise characteristics; (2) two-dimensional wind tunnel testing to determine flight speed effects on performance; and (3) system design and evaluation which integrated the augmentor information obtained into a complete system and ensured that the design was compatible with the requirements for a large STOL transport having a 500-ft sideline noise of 95 PNdB or less. This objective has been achieved.
SRB/SLEEC (Solid Rocket Booster/Shingle Lap Extendible Exit Cone) feasibility study, volume 1
NASA Technical Reports Server (NTRS)
Baker, William H., Jr.
1986-01-01
A preliminary design and analysis was completed for a SLEEC (Shingle Lap Extendible Exit Cone) which could be incorporated on the Space Transportation System (STS) Solid Rocket Booster (SRB). Studies were completed which predicted weights and performance increases and development plans were prepared for the full-scale bench and static test of SLEEC. In conjunction with the design studies, a series of supporting analyses were performed to assure the validity and feasibility of performance, fabrication, cost, and reliability for the selected design. The feasibility and required amounts of bench, static firing, and flight tests considered necessary for the successful incorporation of SLEEC on the Shuttle SRBs were determined. Preliminary plans were completed which define both a follow on study effort and a development program.
Evaluation of substitution monopole models for tire noise sound synthesis
NASA Astrophysics Data System (ADS)
Berckmans, D.; Kindt, P.; Sas, P.; Desmet, W.
2010-01-01
Due to the considerable efforts in engine noise reduction, tire noise has become one of the major sources of passenger car noise nowadays and the demand for accurate prediction models is high. A rolling tire is therefore experimentally characterized by means of the substitution monopole technique, suiting a general sound synthesis approach with a focus on perceived sound quality. The running tire is substituted by a monopole distribution covering the static tire. All monopoles have mutual phase relationships and a well-defined volume velocity distribution which is derived by means of the airborne source quantification technique; i.e. by combining static transfer function measurements with operating indicator pressure measurements close to the rolling tire. Models with varying numbers/locations of monopoles are discussed and the application of different regularization techniques is evaluated.
Serefoglu, Abdullah; Sekir, Ufuk; Gür, Hakan; Akova, Bedrettin
2017-01-01
The aim of this study was to investigate if static and dynamic stretching exercises of the knee muscles (quadriceps and hamstring muscles) have any effects on concentric and eccentric isokinetic peak torques and electromyographic amplitudes (EMG) of the antagonist muscles. Twenty healthy male athletes (age between 18-30 years) voluntarily participated in this study. All of the subjects visited the laboratory to complete the following intervention in a randomized order on 5 separate days; (a) non-stretching (control), (b) static stretching of the quadriceps muscles, (c) static stretching of the hamstring muscles, (d) dynamic stretching of the quadriceps muscles, and (e) dynamic stretching of the hamstring muscles. Static stretching exercises either for the quadriceps or the hamstring muscles were carried out at the standing and sitting positions. Subjects performed four successive repetitions of each stretching exercises for 30 seconds in both stretching positions. Similar to static stretching exercises two different stretching modes were designed for dynamic stretching exercises. Concentric and eccentric isokinetic peak torque for the non-stretched antagonist quadriceps or hamstring muscles at angular velocities of 60°/sec and 240°/sec and their concurrent electromyographic (EMG) activities were measured before and immediately after the intervention. Isokinetic peak torques of the non-stretched agonist hamstring and quadriceps muscles did not represent any significant (p > 0.05) differences following static and dynamic stretching of the antagonist quadriceps and hamstring muscles, respectively. Similarly, the EMG activities of the agonist muscles exhibited no significant alterations (p > 0.05) following both stretching exercises of the antagonist muscles. According to the results of the present study it is possible to state that antagonist stretching exercises either in the static or dynamic modes do not affect the isokinetic peak torques and the EMG activities of the non-stretched agonist quadriceps or hamstring muscles. Key points The effects of dynamic stretching of the antagonist muscles on strength performance are unknown. We showed that both static and dynamic stretching of the antagonist muscle does not influence strength and EMG activities in the agonist muscles. Further research should focus on the effects of antagonist stretching using other techniques like PNF or ballistic stretching and/or different volumes of stretching. PMID:28344445
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, S.; Jang, H.M.
1997-08-01
A classification scheme of Pb(B{sup {prime}}{sub 1/2}B{sup {prime}{prime}}{sub 1/2})O{sub 3}-type perovskites with respect to the B-site order parameters was proposed based on the theoretical calculation of the short-range order parameter ({sigma}) using the pair-correlation model. The calculated order parameters predict that a Pb(B{sup {prime}}{sub 1/2}B{sup {prime}{prime}}{sub 1/2})O{sub 3}-type perovskite without any charge difference between B{sup {prime}} and B{sup {prime}{prime}} cations [e.g., Pb(Zr{sub 1/2}Ti{sub 1/2})O{sub 3} (PZT)] is represented by a completely disordered state with the absence of a finite coherence length. On the other hand, a Pb(B{sup {prime}}{sub 1/2}B{sup {prime}{prime}}{sub 1/2})O{sub 3} type perovskite system having different ionic charges ismore » characterized either by the short-range ordering with a nanoscale coherence length or by the macroscopic long-range ordering, depending on the magnitude of ionic charge difference between B{sup {prime}} and B{sup {prime}{prime}} ions. The normal ferroelectricity in Pb(B{sup {prime}}{sub 1/2}B{sup {prime}{prime}}{sub 1/2})O{sub 3}-type complex perovskites was then correlated either with a completely disordered state ({sigma}=0) or with a perfectly ordered state ({sigma}=1), whereas the relaxor behavior was attributed to the nanoscale short-range ordering (0{lt}{sigma}{lt}1) in the configuration of the B-site cations. {copyright} {ital 1997 Materials Research Society.}« less
Understanding the Role of the ‘Self’ in the Social Priming of Mimicry
Wang, Yin; Hamilton, Antonia F de C
2013-01-01
People have a tendency to unconsciously mimic other's actions. This mimicry has been regarded as a prosocial response which increases social affiliation. Previous research on social priming of mimicry demonstrated an assimilative relationship between mimicry and prosociality of the primed construct: prosocial primes elicit stronger mimicry whereas antisocial primes decrease mimicry. The present research extends these findings by showing that assimilative and contrasting prime-to-behavior effect can both happen on mimicry. Specifically, experiment 1 showed a robust contrast priming effect where priming antisocial behaviors induces stronger mimicry than priming prosocial behaviors. In experiment 2, we manipulated the self-relatedness of the pro/antisocial primes and further revealed that prosocial primes increase mimicry only when the social primes are self-related whereas antisocial primes increase mimicry only when the social primes are self-unrelated. In experiment 3, we used a novel cartoon movie paradigm to prime pro/antisocial behaviors and manipulated the perspective-taking when participants were watching these movies. Again, we found that prosocial primes increase mimicry only when participants took a first-person point of view whereas antisocial primes increase mimicry only when participants took a third-person point of view, which replicated the findings in experiment 2. We suggest that these three studies can be best explained by the active-self theory, which claims that the direction of prime-to-behavior effects depends on how primes are processed in relation to the ‘self’. PMID:23565208
Benefits of rice seed priming are offset permanently by prolonged storage and the storage conditions
Hussain, Saddam; Zheng, Manman; Khan, Fahad; Khaliq, Abdul; Fahad, Shah; Peng, Shaobing; Huang, Jianliang; Cui, Kehui; Nie, Lixiao
2015-01-01
Seed priming is a commercially successful practice, but reduced longevity of primed seeds during storage may limit its application. We established a series of experiments on rice to test: (1) whether prolonged storage of primed and non-primed rice seeds for 210 days at 25°C or −4°C would alter their viability, (2) how long primed rice seed would potentially remain viable at 25°C storage, and (3) whether or not post-storage treatments (re-priming or heating) would reinstate the viability of stored primed seeds. Two different rice cultivars and three priming agents were used in all experiments. Prolonged storage of primed seeds at 25°C significantly reduced the germination (>90%) and growth attributes (>80%) of rice compared with un-stored primed seeds. However, such negative effects were not observed in primed seeds stored at −4°C. Beneficial effects of seed priming were maintained only for 15 days of storage at 25°C, beyond which the performance of primed seeds was worse even than non-primed seeds. The deteriorative effects of 25°C storage were related with hampered starch metabolism in primed rice seeds. None of the post-storage treatments could reinstate the lost viability of primed seeds suggesting that seeds become unviable by prolonged post-priming storage at 25°C. PMID:25631923
User's operating procedures. Volume 1: Scout project information programs
NASA Technical Reports Server (NTRS)
Harris, C. G.; Harris, D. K.
1985-01-01
A review of the user's operating procedures for the Scout Project Automatic Data System, called SPADS is given. SPADS is the result of the past seven years of software development on a Prime minicomputer located at the Scout Project Office. SPADS was developed as a single entry, multiple cross reference data management and information retrieval system for the automation of Project office tasks, including engineering, financial, managerial, and clerical support. The instructions to operate the Scout Project Information programs in data retrieval and file maintenance via the user friendly menu drivers is presented.
Precision cast vs. wrought superalloys
NASA Technical Reports Server (NTRS)
Tien, J. K.; Borofka, J. C.; Casey, M. E.
1986-01-01
While cast polycrystalline superalloys recommend themselves in virtue of better 'buy-to-fly' ratios and higher strengthening gamma-prime volume fractions than those of wrought superalloys, the expansion of their use into such critical superalloy applications as gas turbine hot section components has been slowed by insufficient casting process opportunities for microstructural control. Attention is presently drawn, however, to casting process developments facilitating the production of defect-tolerant superalloy castings having improved fracture reliability. Integrally bladed turbine wheel and thin-walled turbine exhaust case near-net-shape castings have been produced by these means.
1988-11-16
parts was less than for sole source acquired spare parts see, Alan E. Olsen ; James E. Cunningham; and Donald J. Wilkins, "A Cost-Benefit Analysis of...Washington, D.C. Logistc Management-Institute, MUTT- I 339 I Zusman, Morris; Asher, Norman; Wetzler, Elliot; Bennett, Debbie; Gustaves, Selmer ; Higgins...Acquisition." Masters Thesis, Naval Postgraduate School, 1984. Olsen , Alan E.; Cunningham, James E.; and Wilkins, Donald J. "A Cost-Benefit Analysis of
Program document for Energy Systems Optimization Program 2 (ESOP2). Volume 1: Engineering manual
NASA Technical Reports Server (NTRS)
Hamil, R. G.; Ferden, S. L.
1977-01-01
The Energy Systems Optimization Program, which is used to provide analyses of Modular Integrated Utility Systems (MIUS), is discussed. Modifications to the input format to allow modular inputs in specified blocks of data are described. An optimization feature which enables the program to search automatically for the minimum value of one parameter while varying the value of other parameters is reported. New program option flags for prime mover analyses and solar energy for space heating and domestic hot water are also covered.
100 Companies Receiving the Largest Dollar Volume of Prime Contract Awards: Fiscal Year 1988
1988-01-01
CORPORATION 54 CHEVRON CORPORATION 71 MIP INSTANDSETZUNGSBETRIC 70 CHRYSLER CORPORATION 48 MITRE CORPORATION 69 COASTAL CORPORATION THE 57 MOBIL ...10,171 U S SPRINT COMMUNICATIOJS CO 1,710 TOTAL 422,544 0.30 54.88 39 DYNCORP 386,688 C F E SERVICES INC 386 DYN LOGISTICS SERVICES INC 927 DYNAIR...SERVICE CORP 1,936 DYNASPAN SERVICES COMPANY 16,668 HELl DYNE SYSTEMS INC 966 PAC ORD 3,587 SEA MOBILITY INC 10.282 TOTAL 421,440 0.30 55.19 40
1992-01-01
201 F CANADIAN COMMERCIAL CORPORATI 268 B AMTEC CORPORATION 67 N CARNEGIE MELLON UNIVERSITY 118 B ANALYSIS & TECHNOLOGY INC 192 B CAS INC 86 N...LAB INC 342 F GENERAL ELECTRIC CO PLC THE 356 B DU PONT E I DE NEMOURS & CO 3 B GENERAL ELECTRIC COMPANY 325 N DUKE UNIVERSITY 295 N GENERAL HOSPITAL...F SOREQ NUCLEAR RESEARCH CENTER 260 F PORTON INTERNATIONAL INC 55 N SOUTH CAROLINA RESCH AUTHORITY 82 B PRC INC 206 N SOUrTHEASTN CTR ELECTR ENG ED
The priming function of in-car audio instruction.
Keyes, Helen; Whitmore, Antony; Naneva, Stanislava; McDermott, Daragh
2018-05-01
Studies to date have focused on the priming power of visual road signs, but not the priming potential of audio road scene instruction. Here, the relative priming power of visual, audio, and multisensory road scene instructions was assessed. In a lab-based study, participants responded to target road scene turns following visual, audio, or multisensory road turn primes which were congruent or incongruent to the primes in direction, or control primes. All types of instruction (visual, audio, and multisensory) were successful in priming responses to a road scene. Responses to multisensory-primed targets (both audio and visual) were faster than responses to either audio or visual primes alone. Incongruent audio primes did not affect performance negatively in the manner of incongruent visual or multisensory primes. Results suggest that audio instructions have the potential to prime drivers to respond quickly and safely to their road environment. Peak performance will be observed if audio and visual road instruction primes can be timed to co-occur.
The "electrophysiological sandwich": a method for amplifying ERP priming effects.
Ktori, Maria; Grainger, Jonathan; Dufau, Stéphane; Holcomb, Phillip J
2012-08-01
We describe the results of a study that combines ERP recordings and sandwich priming, a variant of masked priming that provides a brief preview of the target prior to prime presentation (S. J. Lupker & C. J. Davis, 2009). This has been shown to increase the size of masked priming effects seen in behavioral responses. We found the same increase in sensitivity to ERP priming effects in an orthographic priming experiment manipulating the position of overlap of letters shared by primes and targets. Targets were 6-letter words and primes were formed of the 1st, 3rd, 4th, and 6th letters of targets in the related condition. Primes could be concatenated or hyphenated and could be centered on fixation or displaced by two letter spaces to the left or right. Priming effects with concatenated and/or displaced primes only started to emerge at 250 ms post-target onset, whereas priming effects from centrally located hyphenated primes emerged about 100 ms earlier. Copyright © 2012 Society for Psychophysiological Research.
The “Electrophysiological Sandwich”: A Method for Amplifying ERP Priming Effects
Ktori, Maria; Grainger, Jonathan; Dufau, Stéphane; Holcomb, Phillip J.
2012-01-01
We describe the results of a study that combines ERP recordings and sandwich priming, a variant of masked priming that provides a brief preview of the target prior to prime presentation (Lupker & Davis, 2009). This has been shown to increase the size of masked priming effects seen in behavioral responses. We found the same increase in sensitivity to ERP priming effects in an orthographic priming experiment manipulating the position of overlap of letters shared by primes and targets. Targets were 6-letter words and primes were formed of the 1st, 3rd, 4th, and 6th letters of targets in the related condition. Primes could be concatenated or hyphenated and could be centered on fixation or displaced by two letter spaces to the left or right. Priming effects with concatenated and/or displaced primes only started to emerge at 250ms post-target onset, whereas priming effects from centrally located hyphenated primes emerged about 100ms earlier. PMID:22681238
Co-occurrence frequency evaluated with large language corpora boosts semantic priming effects.
Brunellière, Angèle; Perre, Laetitia; Tran, ThiMai; Bonnotte, Isabelle
2017-09-01
In recent decades, many computational techniques have been developed to analyse the contextual usage of words in large language corpora. The present study examined whether the co-occurrence frequency obtained from large language corpora might boost purely semantic priming effects. Two experiments were conducted: one with conscious semantic priming, the other with subliminal semantic priming. Both experiments contrasted three semantic priming contexts: an unrelated priming context and two related priming contexts with word pairs that are semantically related and that co-occur either frequently or infrequently. In the conscious priming presentation (166-ms stimulus-onset asynchrony, SOA), a semantic priming effect was recorded in both related priming contexts, which was greater with higher co-occurrence frequency. In the subliminal priming presentation (66-ms SOA), no significant priming effect was shown, regardless of the related priming context. These results show that co-occurrence frequency boosts pure semantic priming effects and are discussed with reference to models of semantic network.
Ultrasonic mixing of epoxy curing agents
NASA Technical Reports Server (NTRS)
Hodges, W. T.; St.clair, T. L.
1983-01-01
A new technique for mixing solid curing agents into liquid epoxy resins using ultrasonic energy was developed. This procedure allows standard curing agents such as 4,4 prime-diaminodiphenyl sulfone (4,4 prime-DDS) and its 3,3 prime-isomer, (3,3 prime-DDS) to be mixed without prior melting of the curing agent. It also allows curing agents such as 4,4 prime-diaminodiphenyl sulfone (4,4 prime-DDS) and its 3,3 prime-isomer, (3,3 prime-DDS) to be mixed without prior melting of the curing agent. It also allows curing agents with very high melt temperatures such as 4,4 prime-diaminobenzophenone (4,4 prime-DABP) (242 C) to be mixed without premature curing. Four aromatic diamines were ultrasonically blended into MY-720 epoxy resin. These were 4,4 prime-DDS; 3,3 prime-DDA; 4,4 prime-DABP and 3,3 prime-DABP. Unfilled moldings were cast and cured for each system and their physical and mechanical properties compared.
Oligomerization of deoxynucleoside-biphosphate dimers - Template and linkage specificity
NASA Technical Reports Server (NTRS)
Visscher, J.; Van Der Woerd, R.; Bakker, C. G.; Schwartz, Alan W.
1989-01-01
The oligomerization of the activated 3-prime-5-prime pyrophosphate-linked dimer, pdAppdAp, is presently noted to be selectively favored by a poly(U) template over the 3-prime-3-prime and 5-prime-5-prime linked dimers. Both overall yields and the production of the longest oligomers were markedly stimulated by poly(U)'s presence; in its absence, the 5-prime-5-prime linked dimer became the most reactive, yielding chains of the order of 60 monomer-unit lengths. Remarkable self-organization properties are noted for the 5-prime-5-prime dimer of pdAp.
A compilation and analysis of helicopter handling qualities data. Volume 2: Data analysis
NASA Technical Reports Server (NTRS)
Heffley, R. K.
1979-01-01
A compilation and an analysis of helicopter handling qualities data are presented. Multiloop manual control methods are used to analyze the descriptive data, stability derivatives, and transfer functions for a six degrees of freedom, quasi static model. A compensatory loop structure is applied to coupled longitudinal, lateral and directional equations in such a way that key handling qualities features are examined directly.
2009-09-01
Review, 39:962, 1964. [8] D. Chaum . Secret ballot receipts: True voter-verifiable elections. IEEE J. Security and Privacy, pages 38–47, 2004. [9...TCC 2005), pages 363–385, 2005. [10] David Clark, Sebastian Hunt, and Pasquale Malacaria. A static analysis for quantifying in- formation flow in a... David Buckingham, editor, MacArthur Foundation Series on Digital Learning– Youth, Identity, Digital Media Volume, Cambridge, MA, 2007. MIT Press. 11
CrossTalk: The Journal of Defense Software Engineering. Volume 23, Number 5, September/October 2010
2010-10-01
paper/static -analysis-when-why-how>. 12. Haddon-Cave, Charles. The Nimrod Review: An Independent Review into the Broader Issues Surrounding the Loss...of the RAF Nimrod MR2 Aircraft XV230 in Afghanistan in 2006: Report. London: TSO. 28 Oct. 2009 <http://ethics. tamu.edu/guest/XV230/1025%5B 1%5D.pdf
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
The Petroleum Marketing Monthly (PMM) provides information and statistical data on a variety of crude oils and refined petroleum products. The publication presents statistics on crude oil costs and refined petroleum products sales for use by industry, government, private sector analysts, educational institutions, and consumers. Data on crude oil include the domestic first purchase price, the f.o.b. and landed cost of imported crude oil, and the refiners` acquisition cost of crude oil. Refined petroleum product sales data include motor gasoline, distillates, residuals, aviation fuels, kerosene, and propane. Monthly statistics on purchases of crude oil and sales of petroleum products aremore » presented in the Petroleum Marketing Monthly in five sections: summary statistics; crude oil prices; prices of petroleum products; volumes of petroleum products; and prime supplier sales volumes of petroleum products for local consumption. 7 figs., 50 tabs.« less
Independent Orbiter Assessment (IOA): CIL issues resolution report, volume 1
NASA Technical Reports Server (NTRS)
Urbanowicz, Kenneth J.; Hinsdale, L. W.; Barnes, J. E.
1988-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. This report contains IOA assessment worksheets showing resolution of outstanding IOA CIL issues that were summarized in the IOA FMEA/CIL Assessment Interim Report, dated 9 March 1988. Each assessment worksheet has been updated with CIL issue resolution and rationale. The NASA and Prime Contractor post 51-L FMEA/CIL documentation assessed is believed to be technically accurate and complete. No assessment issues remain that has safety implications. Volume 1 contain worksheets for the following sybsystems: Landing and Deceleration Subsystem; Purge, Vent and Drain Subsystem; Active Thermal Control and Life Support Systems; Crew Equipment Subsystem; Instrumentation Subsystem; Data Processing Subsystem; Atmospheric Revitalization Pressure Control Subsystem; Hydraulics and Water Spray Boiler Subsystem; and Mechanical Actuation Subsystem.
NASA Technical Reports Server (NTRS)
Resnick, Andrew Howard
1997-01-01
A liquid bridge is a volume of liquid held between two or more solid supports. In the case of small disk supports with a sharp edge, the contact line between the bridge and the support disk will be anchored along the edge of the disk. For these cases the solid presents a geometrical singularity and the contact angle is indeterminate within a given range. This dissertation presents research conducted on liquid bridges with anchored contact lines. The three major topics covered are: determining the role of support geometry on static equilibria, liquid bridge dynamical behavior, and forces exerted by a liquid bridge on a support structure. The work was primarily experimental and conducted in a "Plateau tank" that allowed for the simulation of equivalent low-gravity conditions. The main thrust of the experimental work involved the use of a high resolution optical measurement system for imaging the dynamic zone shape, measurement of the static and dynamic contact angles and non-invasive analysis of excited surface modes. The liquid bridge was manipulated by computer controlled linear actuators which allowed precise control over the physical characteristics of the bridge. Experiments have been carried out to locate a bifurcation point along the maximum volume axisymmetric stability margin. Below the critical slenderness the bifurcation from an axisymmetric to a stable nonaxisymmetric configuration is supercritical. However, above this critical slenderness, the bifurcation is subcritical. A series of experiments analyzed the effect on axisymmetric bridge stability by using support disks of different radii, The shape behavior as transition points were approached, as well as the limiting case of a vanishing support radius was investigated. Experiments were performed to determine the resonant frequencies of axisymmetric bridges subject to lateral vibrations. Anomolous results led to a series of experiments to characterize nonlinearities present in the dynamic bridge shape. Finally, an attempt was made to experimentally measure the force exerted by the bridge on the lower support disk. This was done through use of a force balance apparatus. Particular attention was paid to the behavior of the bridge as the minimum volume stability limit was approached.
Relationships of bone characteristics in MYO9B deficient femurs.
Kim, Do-Gyoon; Jeong, Yong-Hoon; McMichael, Brooke K; Bähler, Martin; Bodnyk, Kyle; Sedlar, Ryan; Lee, Beth S
2018-08-01
The objective of this study was to examine relationships among a variety of bone characteristics, including volumetric, mineral density, geometric, dynamic mechanical analysis, and static fracture mechanical properties. As MYO9B is an unconventional myosin in bone cells responsible for normal skeletal growth, bone characteristics of wild-type (WT), heterozygous (HET), and MYO9B knockout (KO) mice groups were compared as an animal model to express different bone quantity and quality. Forty-five sex-matched 12-week-old mice were used in this study. After euthanization, femurs were isolated and scanned using microcomputed tomography (micro-CT) to assess bone volumetric, tissue mineral density (TMD), and geometric parameters. Then, a non-destructive dynamic mechanical analysis (DMA) was performed by applying oscillatory bending displacement on the femur. Finally, the same femur was subject to static fracture testing. KO group had significantly lower length, bone mineral density (BMD), bone mass and volume, dynamic and static stiffness, and strength than WT and HET groups (p < 0.019). On the other hand, TMD parameters of KO group were comparable with those of WT group. HET group showed volumetric, geometric, and mechanical properties similar to WT group, but had lower TMD (p < 0.014). Non-destructive micro-CT and DMA parameters had significant positive correlations with strength (p < 0.015) without combined effect of groups and sex on the correlations (p > 0.077). This comprehensive characterization provides a better understanding of interactive behavior between the tissue- and organ-level of the same femur. The current findings elucidate that MYO9B is responsible for controlling bone volume to determine the growth rate and fracture risk of bone. Copyright © 2018 Elsevier Ltd. All rights reserved.
Dynamic mechanical characterization of aluminum: analysis of strain-rate-dependent behavior
NASA Astrophysics Data System (ADS)
Rahmat, Meysam
2018-05-01
A significant number of materials show different mechanical behavior under dynamic loads compared to quasi-static (Salvado et al. in Prog. Mater. Sci. 88:186-231, 2017). Therefore, a comprehensive study of material dynamic behavior is essential for applications in which dynamic loads are dominant (Li et al. in J. Mater. Process. Technol. 255:373-386, 2018). In this work, aluminum 6061-T6, as an example of ductile alloys with numerous applications including in the aerospace industry, has been studied under quasi-static and dynamic tensile tests with strain rates of up to 156 s^{-1}. Dogbone specimens were designed, instrumented and tested with a high speed servo-hydraulic load frame, and the results were validated with the literature. It was observed that at a strain rate of 156 s^{-1} the yield and ultimate strength increased by 31% and 33% from their quasi-static values, respectively. Moreover, the failure elongation and fracture energy per unit volume also increased by 18% and 52%, respectively. A Johnson-Cook model was used to capture the behavior of the material at different strain rates, and a modified version of this model was presented to enhance the capabilities of the original model, especially in predicting material properties close to the failure point. Finally, the fracture surfaces of specimens tested under quasi-static and dynamic loads were compared and conclusions about the differences were drawn.
Interaction of biological systems with static and ELF electric and magnetic fields
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anderson, L.E.; Kelman, B.J.; Weigel, R.J.
1987-01-01
Although background levels of atmospheric electric and geomagnetic field levels are extremely low, over the past several decades, human beings and other life forms on this planet have been subjected to a dramatically changing electromagnetic milieu. An exponential increase in exposure to electromagnetic fields has occurred, largely because of such technological advances as the growth of electrical power generation and transmission systems, the increased use of wireless communications, and the use of radar. In addition, electromagnetic field generating devices have proliferated in industrial plants, office buildings, homes, public transportation systems, and elsewhere. Although significant increases have occurred in electromagnetic fieldmore » strenghths spanning all frequency ranges, this symposium addresses only the impact of these fields at static and extremely low frequencies (ELF), primarily 50 and 60 Hz. This volume contains the proceedings of the symposium entitled /open quotes/Interaction of biological systems with static and ELF electric and magnetic fields/close quotes/. The purpose of the symposium was to provide a forum for discussions of all aspects of research on the interaction of static and ELF electromagnetic fields with biological systems. These systems include simple biophysical models, cell and organ preparations, whole animals, and man. Dosimetry, exposure system design, and artifacts in ELF bioeffects research were also addressed, along with current investigations that examine fundamental mechanisms of interactions between the fields and biological processes. Papers are indexed separately.« less
The Effects of Priming on Children's Attitudes toward Older Individuals
ERIC Educational Resources Information Center
Hoe, Sony; Davidson, Denise
2002-01-01
The purpose of the present research was to examine younger (7-years-old) and older (10-years-old) children's attitudes toward older individuals following one type of five primes: positive prime, negative prime, elderly prime, grandparent prime, or neutral prime. Overall, children's attitudes on three tests--Apperception, Semantic Differential, and…
Frič, Radek; Eide, Per Kristian
2017-04-01
OBJECTIVE Several lines of evidence suggest common pathophysiological mechanisms in Chiari malformation Type I (CMI) and idiopathic intracranial hypertension (IIH). It has been hypothesized that tonsillar ectopy, a typical finding in CMI, is the result of elevated intracranial pressure (ICP) combined with a developmentally small posterior cranial fossa (PCF). To explore this hypothesis, the authors specifically investigated whether ICP is comparable in CMI and IIH and whether intracranial volumes (ICVs) are different in patients with CMI and IIH, which could explain the tonsillar ectopy in CMI. The authors also examined whether the symptom profile is comparable in these 2 patient groups. METHODS The authors identified all CMI and IIH patients who had undergone overnight diagnostic ICP monitoring during the period from 2002 to 2014 and reviewed their clinical records and radiological examinations. Ventricular CSF volume (VV), PCF volume (PCFV), and total ICV were calculated from initial MRI studies by using volumetric software. The static and pulsatile ICP scores during overnight monitoring were analyzed. Furthermore, the authors included a reference (REF) group consisting of patients who had undergone ICP monitoring due to suspected idiopathic normal-pressure hydrocephalus or chronic daily headache and showed normal pressure values. RESULTS Sixty-six patients with CMI and 41 with IIH were identified, with comparable demographics noted in both groups. The occurrence of some symptoms (headache, nausea, and/or vomiting) was comparable between the cohorts. Dizziness and gait ataxia were significantly more common in patients with CMI, whereas visual symptoms, diplopia, and tinnitus were significantly more frequent in patients with IIH. The cranial volume measurements (VV, PCFV, and ICV) of the CMI and IIH patients were similar. Notably, 7.3% of the IIH patients had tonsillar descent qualifying for diagnosis of CMI (that is, > 5 mm). The extent of tonsillar ectopy was significantly different between the CMI and IIH cohorts (p < 0.001) but also between these 2 cohorts and the REF group. Pulsatile ICP was elevated in both cohorts without any significant between-group differences; however, static ICP was significantly higher (p < 0.001) in the IIH group. CONCLUSIONS This study showed comparable and elevated pulsatile ICP, indicative of impaired intracranial compliance, in both CMI and IIH cohorts, while static ICP was higher in the IIH cohort. The data did not support the hypothesis that reduced PCFV combined with increased ICP causes tonsillar ectopy in CMI. Even though impaired intracranial compliance seems to be a common pathophysiological mechanism behind both conditions, the mechanisms explaining the different clinical and radiological presentations of CMI and IIH remain undefined.
NASA Astrophysics Data System (ADS)
Aman, Sidra; Zuki Salleh, Mohd; Ismail, Zulkhibri; Khan, Ilyas
2017-09-01
This article focuses on the flow of Maxwell nanofluids with graphene nanoparticles over a vertical plate (static) with constant wall temperature. Possessing high thermal conductivity, engine oil is useful to be chosen as base fluid with free convection. The problem is modelled in terms of PDE’s with boundary conditions. Some suitable non-dimensional variables are interposed to transform the governing equations into dimensionless form. The generated equations are solved via Laplace transform technique. Exact solutions are evaluated for velocity and temperature. These solutions are significantly controlled by some parameters involved. Temperature rises with elevation in volume fraction while Velocity decreases with increment in volume fraction. A comparison with previous published results are established and discussed. Moreover, a detailed discussion is made for influence of volume fraction on the flow and heat profile.
A diffusion model account of masked vs. unmasked priming: Are they qualitatively different?
Gomez, Pablo; Perea, Manuel; Ratcliff, Roger
2017-01-01
In the past decades, hundreds of articles have explored the mechanisms underlying priming. Most researchers assume that masked and unmasked priming are qualitatively different. For masked priming, the effects are often assumed to reflect savings in the encoding of the target stimulus, whereas for unmasked priming, it has been suggested that the effects reflect the familiarity of the prime-target compound cue. In contrast, other researchers have claimed that masked and unmasked priming reflect essentially the same core processes. In this article, we use the diffusion model (Ratcliff, 1978) to account for the effects of masked and unmasked priming for identity and associatively related primes. The fits of the model lead us to the following conclusion: masked related primes give a head start to the processing of the target compared to unrelated primes, while unmasked priming affects primarily the quality of the lexical information. PMID:23647337
Associative priming effects with visible, transposed-letter nonwords: JUGDE facilitates COURT.
Perea, Manuel; Palti, Dafna; Gomez, Pablo
2012-04-01
Associative priming effects can be obtained with masked nonword primes or with masked pseudohomophone primes (e.g., judpe-COURT, tode-FROG), but not with visible primes. The usual explanation is that when the prime is visible, these stimuli no longer activate the semantic representations of their base words. Given the important role of transposed-letter stimuli (e.g., jugde) in visual word recognition, here we examined whether or not an associative priming effect could be obtained with visible transposed-letter nonword primes (e.g., jugde-COURT) in a series of lexical decision experiments. Results showed a sizable associative priming effect with visible transposed-letter nonword primes (i.e., jugde-COURT faster than neevr-COURT) in Experiments 1-3 that was close to that with word primes. In contrast, we failed to find a parallel effect with replacement-letter nonword primes (Experiment 2). These findings pose some constraints to models of visual word recognition.
ERIC Educational Resources Information Center
Weidemann, Christoph T.; Huber, David E.; Shiffrin, Richard M.
2008-01-01
The authors conducted 4 repetition priming experiments that manipulated prime duration and prime diagnosticity in a visual forced-choice perceptual identification task. The strength and direction of prime diagnosticity produced marked effects on identification accuracy, but those effects were resistant to subsequent changes of diagnosticity.…
Gibbons, John P.; Antolak, John A.; Followill, David S.; Huq, M. Saiful; Klein, Eric E.; Lam, Kwok L.; Palta, Jatinder R.; Roback, Donald M.; Reid, Mark; Khan, Faiz M.
2014-01-01
A protocol is presented for the calculation of monitor units (MU) for photon and electron beams, delivered with and without beam modifiers, for constant source-surface distance (SSD) and source-axis distance (SAD) setups. This protocol was written by Task Group 71 of the Therapy Physics Committee of the American Association of Physicists in Medicine (AAPM) and has been formally approved by the AAPM for clinical use. The protocol defines the nomenclature for the dosimetric quantities used in these calculations, along with instructions for their determination and measurement. Calculations are made using the dose per MU under normalization conditions, \\documentclass[12pt]{minimal} \\usepackage{amsmath} \\usepackage{wasysym} \\usepackage{amsfonts} \\usepackage{amssymb} \\usepackage{amsbsy} \\usepackage{upgreek} \\usepackage{mathrsfs} \\setlength{\\oddsidemargin}{-69pt} \\begin{document} }{}$D_0^\\prime $\\end{document}D0′, that is determined for each user's photon and electron beams. For electron beams, the depth of normalization is taken to be the depth of maximum dose along the central axis for the same field incident on a water phantom at the same SSD, where \\documentclass[12pt]{minimal} \\usepackage{amsmath} \\usepackage{wasysym} \\usepackage{amsfonts} \\usepackage{amssymb} \\usepackage{amsbsy} \\usepackage{upgreek} \\usepackage{mathrsfs} \\setlength{\\oddsidemargin}{-69pt} \\begin{document} }{}$D_0^\\prime $\\end{document}D0′ = 1 cGy/MU. For photon beams, this task group recommends that a normalization depth of 10 cm be selected, where an energy-dependent \\documentclass[12pt]{minimal} \\usepackage{amsmath} \\usepackage{wasysym} \\usepackage{amsfonts} \\usepackage{amssymb} \\usepackage{amsbsy} \\usepackage{upgreek} \\usepackage{mathrsfs} \\setlength{\\oddsidemargin}{-69pt} \\begin{document} }{}$D_0^\\prime $\\end{document}D0′ ≤ 1 cGy/MU is required. This recommendation differs from the more common approach of a normalization depth of dm, with \\documentclass[12pt]{minimal} \\usepackage{amsmath} \\usepackage{wasysym} \\usepackage{amsfonts} \\usepackage{amssymb} \\usepackage{amsbsy} \\usepackage{upgreek} \\usepackage{mathrsfs} \\setlength{\\oddsidemargin}{-69pt} \\begin{document} }{}$D_0^\\prime $\\end{document}D0′ = 1 cGy/MU, although both systems are acceptable within the current protocol. For photon beams, the formalism includes the use of blocked fields, physical or dynamic wedges, and (static) multileaf collimation. No formalism is provided for intensity modulated radiation therapy calculations, although some general considerations and a review of current calculation techniques are included. For electron beams, the formalism provides for calculations at the standard and extended SSDs using either an effective SSD or an air-gap correction factor. Example tables and problems are included to illustrate the basic concepts within the presented formalism. PMID:24593704
Measurement of tropospheric OH and HO2 by laser-induced fluorescence at low pressure
NASA Technical Reports Server (NTRS)
Stevens, P. S.; Mather, J. H.; Brune, W. H.
1994-01-01
The hydroxyl radical (OH) is the primary oxidant in the atmosphere, responsible for many photochemical reactions that affect both regional air quality and global climate change. Because of its high reactivity, abundances of OH in the troposphere are less than 1 part per trillion by volume (pptv) and thus difficult to measure accurately. This paper describes an instrument for the sensitive detection of OH in the troposphere using low-pressure laser-induced fluorescence. Ambient air is expanded into a low pressure detection chamber, and OH is both excited and detected using the A(sup 2) Epsilon(+)(v prime = 0) yields X(sup 2)Pi(v double prime = 0) transition near 308 nm. An injector upstream of the detection axis allows for the addition of reagent NO to convert ambient HO2 to OH using the fast reaction HO2 + NO yields OH + NO2. Using recent advances in laser and detector technologies, this prototype instrument is able to detect less than 1 x 10(exp 5) molecules/cu cm (0.004 pptv) of OH with an integration time of 30 s with negligible interferences.
Reproducibility of CVD diamond detectors for radiotherapy dosimetry
NASA Astrophysics Data System (ADS)
Betzel, G. T.; Lansley, S. P.; McKay, D.; Meyer, J.
2012-11-01
Three in-house X-ray detectors based on diamond chemical vapor deposition (CVD) from the same manufactured batch of single crystal films were investigated for their reproducibility. Leakage current, priming dose, response dynamics, dose linearity, dependence on dose rate and angular dependence were used to evaluate differences between detectors. Slight differences were seen in leakage currents before (<1.5 pA) and after (<12 pA) irradiation. A priming dose of ˜7 Gy and rise and fall times of 2 s were found for all three detectors. Sensitivities differed by up to 10%. Dependence on dose rate were similar (∆=0.92-0.94). Angular dependence was minimal (97-102% avg.). Differences in detector performance appeared to be primarily due to film thickness, which can significantly change sensitivities (nC Gy-1) and applied fields (V μm-1) for detectors with small sensitive volumes. Results suggest that preselection of CVD diamond films according to thickness in addition to material quality would be required to avoid individual calibration, which is performed for commercially available natural diamond detectors.
Motor mapping of implied actions during perception of emotional body language.
Borgomaneri, Sara; Gazzola, Valeria; Avenanti, Alessio
2012-04-01
Perceiving and understanding emotional cues is critical for survival. Using the International Affective Picture System (IAPS) previous TMS studies have found that watching humans in emotional pictures increases motor excitability relative to seeing landscapes or household objects, suggesting that emotional cues may prime the body for action. Here we tested whether motor facilitation to emotional pictures may reflect the simulation of the human motor behavior implied in the pictures occurring independently of its emotional valence. Motor-evoked potentials (MEPs) to single-pulse TMS of the left motor cortex were recorded from hand muscles during observation and categorization of emotional and neutral pictures. In experiment 1 participants watched neutral, positive and negative IAPS stimuli, while in experiment 2, they watched pictures depicting human emotional (joyful, fearful), neutral body movements and neutral static postures. Experiment 1 confirms the increase in excitability for emotional IAPS stimuli found in previous research and shows, however, that more implied motion is perceived in emotional relative to neutral scenes. Experiment 2 shows that motor excitability and implied motion scores for emotional and neutral body actions were comparable and greater than for static body postures. In keeping with embodied simulation theories, motor response to emotional pictures may reflect the simulation of the action implied in the emotional scenes. Action simulation may occur independently of whether the observed implied action carries emotional or neutral meanings. Our study suggests the need of controlling implied motion when exploring motor response to emotional pictures of humans. Copyright © 2012 Elsevier Inc. All rights reserved.
Human amygdala response to dynamic facial expressions of positive and negative surprise.
Vrticka, Pascal; Lordier, Lara; Bediou, Benoît; Sander, David
2014-02-01
Although brain imaging evidence accumulates to suggest that the amygdala plays a key role in the processing of novel stimuli, only little is known about its role in processing expressed novelty conveyed by surprised faces, and even less about possible interactive encoding of novelty and valence. Those investigations that have already probed human amygdala involvement in the processing of surprised facial expressions either used static pictures displaying negative surprise (as contained in fear) or "neutral" surprise, and manipulated valence by contextually priming or subjectively associating static surprise with either negative or positive information. Therefore, it still remains unresolved how the human amygdala differentially processes dynamic surprised facial expressions displaying either positive or negative surprise. Here, we created new artificial dynamic 3-dimensional facial expressions conveying surprise with an intrinsic positive (wonderment) or negative (fear) connotation, but also intrinsic positive (joy) or negative (anxiety) emotions not containing any surprise, in addition to neutral facial displays either containing ("typical surprise" expression) or not containing ("neutral") surprise. Results showed heightened amygdala activity to faces containing positive (vs. negative) surprise, which may either correspond to a specific wonderment effect as such, or to the computation of a negative expected value prediction error. Findings are discussed in the light of data obtained from a closely matched nonsocial lottery task, which revealed overlapping activity within the left amygdala to unexpected positive outcomes. PsycINFO Database Record (c) 2014 APA, all rights reserved.
Imide modified epoxy matrix resins
NASA Technical Reports Server (NTRS)
Scola, D. A.
1982-01-01
Results of a program designed to develop tough imide modified epoxy (IME) resins cured by bisimide amine (BIA) hardeners are presented. State of the art epoxy resin, MY720, was used. Three aromatic bisimide amines and one aromatic aliphatic BIA were evaluated. BIA's derived from 6F anhydride (3,3 prime 4,4 prime-(hexafluoro isopropyl idene) bis (phthalic anhydride) and diamines, 3,3 prime-diam nodiphenyl sulfone (3,3 prime-DDS), 4,4 prime-diamino diphenyl sulfone (4,4 prime-DDS), 1.12-dodecane diamine (1,12-DDA) were used. BIA's were abbreviated 6F-3,3 prime-DDS, 6F-4,4 prime-DDS, 6F-3,3 prime-DDS-4,4 prime DDS, and 6F-3,3 prime-DDS-1,12-DDA corresponding to 6F anhydride and diamines mentioned. Epoxy resin and BIA's (MY720/6F-3,3 prime-DDS, MY720/6F-3,3 prime-DDS-4,4 prime-DDS, MY720/6F-3,3 prime-DDS-1,12-DDA and a 50:50 mixture of a BIA and parent diamine, MY720/6F-3,3 prime-DDS/3,3 prime-DDS, MY720/6F-3,3 prime-DDS-4,4 prime-DDS/3,3 prime-DDS, MY720/6F-3,3 prime-DDS-1,12-DDA/3,3 prime-DDS were studied to determine effect of structure and composition. Effect of the addition of two commercial epoxies, glyamine 200 and glyamine 100 on the properties of several formulations was evaluated. Bisimide amine cured epoxies were designated IME's (imide modified epoxy). Physical, thermal and mechanical properties of these resins were determined. Moisture absorption in boiling water exhibited by several of the IME's was considerably lower than the state of the art epoxies (from 3.2% for the control and state of the art to 2.0 wt% moisture absorption). Char yields are increased from 20% for control and state of the art epoxies to 40% for IME resins. Relative toughness characteristics of IME resins were measured by 10 deg off axis tensile tests of Celion 6000/IME composites. Results show that IME's containing 6F-3,3 prime-DDS or 6F-3,3 prime-DDS-1,12-DDA improved the "toughness" characteristics of composites by about 35% (tensile strength), about 35% (intralaminar shear strength), and about 78% (shear strain to failure) relative to the control composite.
The more you ignore me the closer I get: An ERP study of evaluative priming.
Gibbons, Henning; Bachmann, Olga; Stahl, Jutta
2014-12-01
We used event-related brain potentials (ERPs) to investigate the various mental processes contributing to evaluative priming-that is, more positive judgments for targets preceded by affectively positive, as opposed to negative, prime stimuli. To ensure ecological validity, we employed a priori meaningful landscape pictures as targets and emotional adjectives as visual primes and presented both primes and targets for relatively long durations (>1 s). Prime-related lateralized readiness potentials (LRPs) revealed response priming as one source of the significant evaluative priming effect. On the other hand, greater right-frontal positive slow wave in the ERP for pictures following negative, as compared with positive, primes indicated altered impression formation, thus supporting automatic spreading activation and/or affect misattribution accounts. Moreover, target LRPs suggested conscious counter-control to reduce the evaluative priming net effect. Finally, when comparing prime ERPs for two groups of participants showing strong versus weak evaluative priming, we found strong evidence for the role of depth of prime processing: In the weak-effect group, prime words evoked an increased visual P1/N1 complex, a larger posterior P2 component, and a greater left-parietal processing negativity presumably reflecting semantic processing. By contrast, a larger medial-frontal P2/N2 complex in the strong-effect group suggested top-down inhibition of the prime's emotional content. Thus, trying to ignore the primes can actually increase, rather than decrease, the evaluative priming effect.
Farstad, Marit; Kvalheim, Venny Lise; Husby, Paul
2005-08-01
Hypothermic cardiopulmonary bypass is associated with increased fluid extravasation. This study aimed to compare whether iso-oncotic priming solutions, in contrast to crystalloids, could reduce the cold-induced fluid extravasation during cardiopulmonary bypass in piglets. Three groups were studied: the control group (CT group; n = 10), the albumin group (Alb group; n = 7), and the hydroxyethyl starch group (HES group; n = 7). Prime (1000 mL) and supplemental fluid were acetated Ringer solution, 4% albumin, and 6% hydroxyethyl starch, respectively. After 1 hour of normothermic cardiopulmonary bypass, hypothermic cardiopulmonary bypass (cooling to 28 degrees C within 15 minutes) was initiated and continued to 90 minutes. Fluid needs, plasma volume, changes in colloid osmotic pressure in plasma and interstitial fluid, hematocrit levels, and tissue water content were recorded, and protein masses and fluid extravasation rates were calculated. Colloid osmotic pressure in plasma decreased immediately after the start of cardiopulmonary bypass in the CT group but remained stable in the Alb and HES groups. Colloid osmotic pressure in interstitial fluid tended to decrease in the CT group and remained unchanged in the Alb group, whereas a slight increase was observed in the HES group. Immediately after the start of cooling, fluid extravasation rates increased from 0.15 +/- 0.10 to 0.64 +/- 0.12 mL . kg -1 . min -1 in the CT group, whereas no such increase was observed in the Alb and HES groups. The changes in fluid extravasation rates were reflected by corresponding changes in tissue water content. The use of albumin or hydroxyethyl starch as prime to preserve the colloid osmotic pressure during cardiopulmonary bypass causes a reduction in the cold-induced fluid extravasation compared with that seen with crystalloids. Albumin seems more effective than hydroxyethyl starch to limit cold-induced fluid shifts during cardiopulmonary bypass.
Viegas, Edna Omar; Tembe, Nelson; Nilsson, Charlotta; Meggi, Bindiya; Maueia, Cremildo; Augusto, Orvalho; Stout, Richard; Scarlatti, Gabriella; Ferrari, Guido; Earl, Patricia L; Wahren, Britta; Andersson, Sören; Robb, Merlin L; Osman, Nafissa; Biberfeld, Gunnel; Jani, Ilesh; Sandström, Eric
2017-11-27
We assessed the safety and immunogenicity of HIV-DNA priming using Zetajet™, a needle-free device intradermally followed by intramuscular HIV-MVA boosts, in 24 healthy Mozambicans. Volunteers were randomized to receive three immunizations of 600 μg (n = 10; 2 × 0.1 ml) or 1,200 μg (n = 10; 2 × 0.2 ml) of HIV-DNA (3 mg/ml), followed by two boosts of 10 8 pfu HIV-MVA. Four subjects received placebo saline injections. Vaccines and injections were safe and well tolerated with no difference between the two priming groups. After three HIV-DNA immunizations, IFN-γ ELISpot responses to Gag were detected in 9/17 (53%) vaccinees, while none responded to Envelope (Env). After the first HIV-MVA, the overall response rate to Gag and/or Env increased to 14/15 (93%); 14/15 (93%) to Gag and 13/15 (87%) to Env. There were no significant differences between the immunization groups in frequency of response to Gag and Env or magnitude of Gag responses. Env responses were significantly higher in the higher dose group (median 420 vs. 157.5 SFC/million peripheral blood mononuclear cell, p = .014). HIV-specific antibodies to subtype C gp140 and subtype B gp160 were elicited in all vaccinees after the second HIV-MVA, without differences in titers between the groups. Neutralizing antibody responses were not detected. Two (13%) of 16 vaccinees, one in each of the priming groups, exhibited antibodies mediating antibody-dependent cellular cytotoxicity to CRF01_AE. In conclusion, HIV-DNA vaccine delivered intradermally in volumes of 0.1-0.2 ml using Zetajet was safe and well tolerated. Priming with the 1,200 μg dose of HIV-DNA generated higher magnitudes of ELISpot responses to Env.
Leachman, Sancy A.; Tigelaar, Robert E.; Shlyankevich, Mark; Slade, Martin D.; Irwin, Michele; Chang, Ed; Wu, T. C.; Xiao, Wei; Pazhani, Sundaram; Zelterman, Daniel; Brandsma, Janet L.
2000-01-01
A cottontail rabbit papillomavirus (CRPV) E6 DNA vaccine that induces significant protection against CRPV challenge was used in a superior vaccination regimen in which the cutaneous sites of vaccination were primed with an expression vector encoding granulocyte-macrophage colony-stimulating factor (GM-CSF), a cytokine that induces differentiation and local recruitment of professional antigen-presenting cells. This treatment induced a massive influx of major histocompatibility complex class II-positive cells. In a vaccination-challenge experiment, rabbit groups were treated by E6 DNA vaccination, GM-CSF DNA inoculation, or a combination of both treatments. After two immunizations, rabbits were challenged with CRPV at low, moderate, and high stringencies and monitored for papilloma formation. As expected, all clinical outcomes were monotonically related to the stringency of the viral challenge. The results demonstrate that GM-CSF priming greatly augmented the effects of CRPV E6 vaccination. First, challenge sites in control rabbits (at the moderate challenge stringency) had a 0% probability of remaining disease free, versus a 50% probability in E6-vaccinated rabbits, and whereas GM-CSF alone had no effect, the interaction between GM-CSF priming and E6 vaccination increased disease-free survival to 67%. Second, the incubation period before papilloma onset was lengthened by E6 DNA vaccination alone or to some extent by GM-CSF DNA inoculation alone, and the combination of treatments induced additive effects. Third, the rate of papilloma growth was reduced by E6 vaccination and, to a lesser extent, by GM-CSF treatment. In addition, the interaction between the E6 and GM-CSF treatments was synergistic and yielded more than a 99% reduction in papilloma volume. Finally, regression occurred among the papillomas that formed in rabbits treated with the E6 vaccine and/or with GM-CSF, with the highest regression frequency occurring in rabbits that received the combination treatment. PMID:10954571
Unconscious response priming during continuous flash suppression
Grassini, Simone
2018-01-01
Continuous flash suppression (CFS) has become a popular tool for studying unconscious processing, but the level at which unconscious processing of visual stimuli occurs under CFS is not clear. Response priming is a robust and well-understood phenomenon, in which the prime stimulus facilitates overt responses to targets if the prime and target are associated with the same response. We used CFS to study unconscious response priming of shape: arrows with left or right orientation served as primes and targets. The prime was presented near the limen of consciousness and each trial was followed by subjective rating of visibility and a forced-choice response concerning the orientation of the prime in counterbalanced order. In trials without any reported awareness of the presence of the prime, discrimination of the prime’s orientation was at chance level. However, priming was elicited in such unconscious trials. Unconscious priming was not influenced by the prime-target onset-asynchrony (SOA)/prime duration, whereas conscious processing, as indicated by the enhanced discriminability of the prime’s orientation and conscious priming, increased at the longest SOAs/prime durations. These results show that conscious and unconscious processes can be dissociated with CFS and that CFS-masking does not completely suppress unconscious visual processing of shape. PMID:29401503
Collider Signals of a Composite Higgs in the Standard Model with Four Generations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Soni, A.; Bar-Shalom, S.; Eilam, G.
2010-03-20
Recent fits of electroweak precision data to the StandardModel (SM) with a 4th sequential family (SM4) point to a possible 'three-prong composite solution': (1) the Higgs mass is at the TeV-scale, (2) the masses of the 4th family quarks t{prime}, b{prime} are of {Omicron}(500) GeV and (3) the mixing angle between the 4th and 3rd generation quarks is of the order of the Cabibbo angle, {theta}{sub 34} {approx} {Omicron}(0.1). Such a manifestation of the SM4 is of particular interest as it may suggest that the Higgs is a composite state, predominantly of the 4th generation heavy quarks. Motivated by themore » above, we show that the three-prong composite solution to the SM4 can have interesting new implications for Higgs phenomenology. For example, the Higgs can decay to a single heavy 4th generation quark via the 3-body decays (through an off-shell t{prime} or b{prime}) H {yields} {bar t}{prime}t{prime}* {yields} {bar t}{prime}bW{sup +} and H {yields} {bar b}{prime}b{prime}* {yields} {bar b}{prime}tW{sup -}. These flavor diagonal decays can be dramatically enhanced at the LHC (by several orders of magnitudes) due to the large width effects of the resonating heavy Higgs in the processes gg {yields} H {yields} {bar t}{prime}t{prime}* {yields} {bar t}{prime}bW{sup +} and gg {yields} H {yields} {bar b}{prime}b{prime}* {yields} {bar b}{prime}tW{sup -}, thus yielding a viable signal above the corresponding continuum QCD production rates. In addition, the Higgs can decay to a single t{prime} and b{prime} in the loop-generated flavor changing (FC) channels H {yields} b{prime}{bar b}, t{prime}{bar t}. These FC decays are essentially 'GIM-free' and can, therefore, have branching ratios as large as 10{sup -4} - 10{sup -3}.« less
Reversed Priming Effects May Be Driven by Misperception Rather than Subliminal Processing.
Sand, Anders
2016-01-01
A new paradigm for investigating whether a cognitive process is independent of perception was recently suggested. In the paradigm, primes are shown at an intermediate signal strength that leads to trial-to-trial and inter-individual variability in prime perception. Here, I used this paradigm and an objective measure of perception to assess the influence of prime identification responses on Stroop priming. I found that sensory states producing correct and incorrect prime identification responses were also associated with qualitatively different priming effects. Incorrect prime identification responses were associated with reversed priming effects but in contrast to previous studies, I interpret this to result from the (mis-)perception of primes rather than from a subliminal process. Furthermore, the intermediate signal strength also produced inter-individual variability in prime perception that strongly influenced priming effects: only participants who on average perceived the primes were Stroop primed. I discuss how this new paradigm, with a wide range of d' values, is more appropriate when regression analysis on inter-individual identification performance is used to investigate perception-dependent processing. The results of this study, in line with previous results, suggest that drawing conclusions about subliminal processes based on data averaged over individuals may be unwarranted.
Reversed Priming Effects May Be Driven by Misperception Rather than Subliminal Processing
Sand, Anders
2016-01-01
A new paradigm for investigating whether a cognitive process is independent of perception was recently suggested. In the paradigm, primes are shown at an intermediate signal strength that leads to trial-to-trial and inter-individual variability in prime perception. Here, I used this paradigm and an objective measure of perception to assess the influence of prime identification responses on Stroop priming. I found that sensory states producing correct and incorrect prime identification responses were also associated with qualitatively different priming effects. Incorrect prime identification responses were associated with reversed priming effects but in contrast to previous studies, I interpret this to result from the (mis-)perception of primes rather than from a subliminal process. Furthermore, the intermediate signal strength also produced inter-individual variability in prime perception that strongly influenced priming effects: only participants who on average perceived the primes were Stroop primed. I discuss how this new paradigm, with a wide range of d′ values, is more appropriate when regression analysis on inter-individual identification performance is used to investigate perception-dependent processing. The results of this study, in line with previous results, suggest that drawing conclusions about subliminal processes based on data averaged over individuals may be unwarranted. PMID:26925016
Motor Priming in Neurorehabilitation
Stoykov, Mary Ellen; Madhavan, Sangeetha
2014-01-01
Priming is a type of implicit learning wherein a stimulus prompts a change in behavior. Priming has been long studied in the field of psychology. More recently, rehabilitation researchers have studied motor priming as a possible way to facilitate motor learning. For example, priming of the motor cortex is associated with changes in neuroplasticity that are associated with improvements in motor performance. Of the numerous motor priming paradigms under investigation, only a few are practical for the current clinical environment, and the optimal priming modalities for specific clinical presentations are not known. Accordingly, developing an understanding of the various types of motor priming paradigms and their underlying neural mechanisms is an important step for therapists in neurorehabilitation. Most importantly, an understanding of the methods and their underlying mechanisms is essential for optimizing rehabilitation outcomes. The future of neurorehabilitation is likely to include these priming methods, which are delivered prior to or in conjunction with primary neurorehabilitation therapies. In this Special Interest article we discuss those priming paradigms that are supported by the greatest amount of evidence including: (i) stimulation-based priming, (ii) motor imagery and action observation, (iii) sensory priming, (iv) movement-based priming, and (v) pharmacological priming. PMID:25415551
How polarizabilities and C6 coefficients actually vary with atomic volume
NASA Astrophysics Data System (ADS)
Gould, Tim
2016-08-01
In this work, we investigate how atomic C6 coefficients and static dipole polarizabilities α scale with effective volume. We show, using confined atoms covering rows 1-5 of the periodic table, that C 6 / C6 R ≈ ( V / VR ) p Z and α / α R ≈ ( V / VR ) pZ ' (for volume V = ∫ d r /4 π 3 r 3 n ( r ) ), where C6 R , αR, and VR are the reference values and effective volume of the free atom. The scaling exponents pZ and pZ ' vary substantially as a function of element number Z = N, in contrast to the standard "rule of thumb" that pZ = 2 and pZ ' = 1 . Remarkably, we find that the polarizability and C6 exponents p' and p are related by p' ≈ p - 0.615 rather than the expected p' ≈ p/2. Results are largely independent of the form of the confining potential (harmonic, cubic, and quartic potentials are considered) and kernel approximation, justifying this analysis.
Laser-based volumetric flow visualization by digital color imaging of a spectrally coded volume.
McGregor, T J; Spence, D J; Coutts, D W
2008-01-01
We present the framework for volumetric laser-based flow visualization instrumentation using a spectrally coded volume to achieve three-component three-dimensional particle velocimetry. By delivering light from a frequency doubled Nd:YAG laser with an optical fiber, we exploit stimulated Raman scattering within the fiber to generate a continuum spanning the visible spectrum from 500 to 850 nm. We shape and disperse the continuum light to illuminate a measurement volume of 20 x 10 x 4 mm(3), in which light sheets of differing spectral properties overlap to form an unambiguous color variation along the depth direction. Using a digital color camera we obtain images of particle fields in this volume. We extract the full spatial distribution of particles with depth inferred from particle color. This paper provides a proof of principle of this instrument, examining the spatial distribution of a static field and a spray field of water droplets ejected by the nozzle of an airbrush.
Effects of Religious Priming Concepts on Prosocial Behavior Towards Ingroup and Outgroup.
Batara, Jame Bryan L; Franco, Pamela S; Quiachon, Mequia Angelo M; Sembrero, Dianelle Rose M
2016-11-01
Several studies show that there is a connection between religion and prosociality (e.g., Saroglou, 2013). To investigate whether there is a causal relationship between these two variables, a growing number of scholars employed priming religious concepts and measure its influence on prosocial behavior (e.g., Pichon, Boccato, & Saroglou, 2007). In the recent development of religious priming, Ritter and Preston (2013) argued that different primes (agent prime, spiritual/abstract prime, and institutional prime) may also have varying influence on prosocial behavior specifically helping an ingroup or an outgroup target. With this in mind, a 2 (social categorization of the target of help) by 3 (agent prime, institutional prime, spiritual prime) experiment was conducted to directly investigate this hypothesis. Results suggest that priming religious concepts especially the spiritual prime can increase prosocial behaviors. However, no significant effect was found on the social categorization which implies that Filipino participants elicit prosocial behavior regardless of the social categorization (be it ingroup or outgroup) of the target of help. The present study's findings contribute to further the literature on religious priming and its influence on prosocial behavior.
Semantic priming effects from single words in a lexical decision task.
Noguera, Carmen; Ortells, Juan J; Abad, María J F; Carmona, Encarnación; Daza, M Teresa
2007-06-01
The present research examines the semantic priming effects of a centrally presented single prime word to which participants were instructed to either "attend and remember" or "ignore". The prime word was followed by a central probe target on which the participants made a lexical decision task. The main variables manipulated across experiments were prime duration (50 or 100 ms), the presence or absence of a mask following the prime, and the presence (or absence) and type of distractor stimulus (random set of consonants or pseudowords) on the probe display. There was a consistent interaction between the instructions and the semantic priming effects. Relative to the "attend and remember" instruction, an "ignore" instruction produced reduced positive priming from single primes presented for 100 ms, irrespective of the presence or absence of a prime mask, and regardless of whether the probe target was presented with or without distractors. Additionally, reliable negative priming was found from ignored primes presented for briefer durations (50 ms) and immediately followed by a mask. Methodological and theoretical implications of the present findings for the extant negative priming literature are discussed.
Interaction of prime and target in the subliminal affective priming effect.
Haneda, Kaoruko; Nomura, Michio; Iidaka, Tetsuya; Ohira, Hideki
2003-04-01
It has been found that an emotional stimulus such as a facial expression presented subliminally can affect subsequent information processing and behavior, usually by shifting evaluation of a subsequent stimulus to a valence congruent with the previous stimulus. This phenomenon is called subliminal affective priming. The present study was conducted to replicate and expand previous findings by investigating interaction of primes and targets in the affective priming effect. Two conditions were used. Prime (subliminal presentation 35 msec.) of an angry face of a woman and a No Prime control condition. Just after presentation of the prime, an ambiguous angry face or an emotionally neutral face was presented above the threshold of awareness (500 msec.). 12 female undergraduate women judged categories of facial expressions (Anger, Neutral, or Happiness) for the target faces. Analysis indicated that the Anger primes significantly facilitated judgment of anger for the ambiguous angry faces; however, the priming effect of the Anger primes was not observed for neutral faces. Consequently, the present finding suggested that a subliminal affective priming effect should be more prominent when affective valence of primes and targets is congruent.
Stone, Anna
2012-05-01
A centre-surround attentional mechanism was proposed by Carr and Dagenbach (Journal of Experimental Psychology: Learning, Memory, and Cognition 16: 341-350, 1990) to account for their observations of negative semantic priming from hard-to-perceive primes. Their mechanism cannot account for the observation of negative semantic priming when primes are clearly visible. Three experiments (Ns = 30, 46, and 30) used a familiarity decision with names of famous people, preceded by a prime name with the same occupation as the target or with a different occupation. Negative semantic priming was observed at a 150- or 200-ms SOA, with positive priming at shorter (50-ms) and longer (1,000-ms) SOAs. In Experiment 3, we verified that the primes were easily recognisable in the priming task at an SOA that yielded negative semantic priming, which cannot be predicted by the original centre-surround mechanism. A modified version is proposed that explains transiently negative semantic priming by proposing that centre-surround inhibition is a normal, automatically invoked aspect of the semantic processing of visually presented famous names.
Jahani, Nariman; Choi, Jiwoong; Iyer, Krishna; Hoffman, Eric A.
2015-01-01
This study aims to assess regional ventilation, nonlinearity, and hysteresis of human lungs during dynamic breathing via image registration of four-dimensional computed tomography (4D-CT) scans. Six healthy adult humans were studied by spiral multidetector-row CT during controlled tidal breathing as well as during total lung capacity and functional residual capacity breath holds. Static images were utilized to contrast static vs. dynamic (deep vs. tidal) breathing. A rolling-seal piston system was employed to maintain consistent tidal breathing during 4D-CT spiral image acquisition, providing required between-breath consistency for physiologically meaningful reconstructed respiratory motion. Registration-derived variables including local air volume and anisotropic deformation index (ADI, an indicator of preferential deformation in response to local force) were employed to assess regional ventilation and lung deformation. Lobar distributions of air volume change during tidal breathing were correlated with those of deep breathing (R2 ≈ 0.84). Small discrepancies between tidal and deep breathing were shown to be likely due to different distributions of air volume change in the left and the right lungs. We also demonstrated an asymmetric characteristic of flow rate between inhalation and exhalation. With ADI, we were able to quantify nonlinearity and hysteresis of lung deformation that can only be captured in dynamic images. Nonlinearity quantified by ADI is greater during inhalation, and it is stronger in the lower lobes (P < 0.05). Lung hysteresis estimated by the difference of ADI between inhalation and exhalation is more significant in the right lungs than that in the left lungs. PMID:26316512
Basic features of boron isotope separation by SILARC method in the two-step iterative static model
NASA Astrophysics Data System (ADS)
Lyakhov, K. A.; Lee, H. J.
2013-05-01
In this paper we develop a new static model for boron isotope separation by the laser assisted retardation of condensation method (SILARC) on the basis of model proposed by Jeff Eerkens. Our model is thought to be adequate to so-called two-step iterative scheme for isotope separation. This rather simple model helps to understand combined action on boron separation by SILARC method of all important parameters and relations between them. These parameters include carrier gas, molar fraction of BCl3 molecules in carrier gas, laser pulse intensity, gas pulse duration, gas pressure and temperature in reservoir and irradiation cells, optimal irradiation cell and skimmer chamber volumes, and optimal nozzle throughput. A method for finding optimal values of these parameters based on some objective function global minimum search was suggested. It turns out that minimum of this objective function is directly related to the minimum of total energy consumed, and total setup volume. Relations between nozzle throat area, IC volume, laser intensity, number of nozzles, number of vacuum pumps, and required isotope production rate were derived. Two types of industrial scale irradiation cells are compared. The first one has one large throughput slit nozzle, while the second one has numerous small nozzles arranged in parallel arrays for better overlap with laser beam. It is shown that the last one outperforms the former one significantly. It is argued that NO2 is the best carrier gas for boron isotope separation from the point of view of energy efficiency and Ar from the point of view of setup compactness.
Mechanistic studies of ribonucleoside triphosphate reductase from Lactobacillus leichmannii
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harris, G.M.
1984-01-01
The mechanism of action of the adenosylcobalamin (AdoCbl)-dependent ribonucleoside triphosphate reductase (RTPR) was investigated using isotope effect and substrate specificity studies. These experiments were conducted on RTPR purified by a new method from Lactobacillus leichmannii. Isotope effect studies using (3{prime}-{sup 3}H)UTP and (3{prime}-{sup 3}H)ATP demonstrated that the 3{prime} C-H bond of the nucleotide is cleaved in order to cleave the 2{prime} C-OH bond. AdoCbl does not act as a direct H abstractor from the 3{prime} position of the substrate, but instead is thought to act as a radical chain initiator to generate an amino acid radical on the enzyme. Furthermore » support for this enzyme mediated cleavage of the 3{prime} C-H bond of the nucleotide and the novel role of AdoCbl came from studies using (3{prime}{sup 3}H)2{prime}-chloro-2{prime}-deoxyuridine 5{prime}-triphosphate ((3{prime}-{sup 3}H)CIUTP). Evidence is presented that during the course of this reaction, the {sup 3}H abstracted from the 3{prime} position of (3{prime}-{sup 3}H)CIUTP was either exchanged with the solvent or returned to the {beta} face of the 2{prime} position to produce (2{prime}{sup 3}H)-2{prime}-deoxy-3{prime}-ketoUTP. This result demonstrates that RTPR is capable of catalyzing a rearrangement reaction. The significance of the RTPR-catalyzed rearrangement with respect to the AdoCbl-dependent enzymes which catalyze rearrangements is discussed.« less
Automatic response activation in sequential affective priming: an ERP study
Leuthold, Hartmut; Rothermund, Klaus; Schweinberger, Stefan R.
2012-01-01
Affective priming effects denote faster responses when two successively presented affective stimuli match in valence than when they mismatch. Two mechanisms have been proposed for their explanation: (i) Priming of affective information within a semantic network or distributed memory system (semantic priming). (ii) Automatic activation of the evaluative response through the affective prime (response priming). In this experiment, we sought more direct evidence for prime-induced response activations with measurement of the lateralized readiness potential (LRP). Onset of the stimulus-locked LRP was earlier in affectively congruent trials than in incongruent trials. In addition, priming modulated the LRP-amplitude of slow responses, indicating greater activation of the incorrect response hand in affectively incongruent trials. Onset of the response-locked LRP and peak latency of the P300 component were not modulated by priming but the amplitude of the N400 component was. In combination, these results suggest that both, semantic priming and response priming constitute affective priming effects in the evaluative categorization task. PMID:21642351
The (un)reliability of item-level semantic priming effects.
Heyman, Tom; Bruninx, Anke; Hutchison, Keith A; Storms, Gert
2018-04-05
Many researchers have tried to predict semantic priming effects using a myriad of variables (e.g., prime-target associative strength or co-occurrence frequency). The idea is that relatedness varies across prime-target pairs, which should be reflected in the size of the priming effect (e.g., cat should prime dog more than animal does). However, it is only insightful to predict item-level priming effects if they can be measured reliably. Thus, in the present study we examined the split-half and test-retest reliabilities of item-level priming effects under conditions that should discourage the use of strategies. The resulting priming effects proved extremely unreliable, and reanalyses of three published priming datasets revealed similar cases of low reliability. These results imply that previous attempts to predict semantic priming were unlikely to be successful. However, one study with an unusually large sample size yielded more favorable reliability estimates, suggesting that big data, in terms of items and participants, should be the future for semantic priming research.
Boehm, Stephan G; Smith, Ciaran; Muench, Niklas; Noble, Kirsty; Atherton, Catherine
2017-08-31
Repetition priming increases the accuracy and speed of responses to repeatedly processed stimuli. Repetition priming can result from two complementary sources: rapid response learning and facilitation within perceptual and conceptual networks. In conceptual classification tasks, rapid response learning dominates priming of object recognition, but it does not dominate priming of person recognition. This suggests that the relative engagement of network facilitation and rapid response learning depends on the stimulus domain. Here, we addressed the importance of the stimulus domain for rapid response learning by investigating priming in another domain, brands. In three experiments, participants performed conceptual decisions for brand logos. Strong priming was present, but it was not dominated by rapid response learning. These findings add further support to the importance of the stimulus domain for the relative importance of network facilitation and rapid response learning, and they indicate that brand priming is more similar to person recognition priming than object recognition priming, perhaps because priming of both brands and persons requires individuation.
ERIC Educational Resources Information Center
Tse, Chi-Shing; Neely, James H.
2007-01-01
Letter-search (LS) within a prime often eliminates semantic priming. In 2 lexical decision experiments, the authors found that priming from LS primes occurred for low-frequency (LF) but not high-frequency (HF) targets whether the target's word frequency was manipulated between or within participants and whether the prime-target pairs were…
On the road to somewhere: Brain potentials reflect language effects on motion event perception.
Flecken, Monique; Athanasopoulos, Panos; Kuipers, Jan Rouke; Thierry, Guillaume
2015-08-01
Recent studies have identified neural correlates of language effects on perception in static domains of experience such as colour and objects. The generalization of such effects to dynamic domains like motion events remains elusive. Here, we focus on grammatical differences between languages relevant for the description of motion events and their impact on visual scene perception. Two groups of native speakers of German or English were presented with animated videos featuring a dot travelling along a trajectory towards a geometrical shape (endpoint). English is a language with grammatical aspect in which attention is drawn to trajectory and endpoint of motion events equally. German, in contrast, is a non-aspect language which highlights endpoints. We tested the comparative perceptual saliency of trajectory and endpoint of motion events by presenting motion event animations (primes) followed by a picture symbolising the event (target): In 75% of trials, the animation was followed by a mismatching picture (both trajectory and endpoint were different); in 10% of trials, only the trajectory depicted in the picture matched the prime; in 10% of trials, only the endpoint matched the prime; and in 5% of trials both trajectory and endpoint were matching, which was the condition requiring a response from the participant. In Experiment 1 we recorded event-related brain potentials elicited by the picture in native speakers of German and native speakers of English. German participants exhibited a larger P3 wave in the endpoint match than the trajectory match condition, whereas English speakers showed no P3 amplitude difference between conditions. In Experiment 2 participants performed a behavioural motion matching task using the same stimuli as those used in Experiment 1. German and English participants did not differ in response times showing that motion event verbalisation cannot readily account for the difference in P3 amplitude found in the first experiment. We argue that, even in a non-verbal context, the grammatical properties of the native language and associated sentence-level patterns of event encoding influence motion event perception, such that attention is automatically drawn towards aspects highlighted by the grammar. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.
Toh, Yi-Chin; Voldman, Joel
2011-01-01
Shear stress is a ubiquitous environmental cue experienced by stem cells when they are being differentiated or expanded in perfusion cultures. However, its role in modulating self-renewing stem cell phenotypes is unclear, since shear is usually only studied in the context of cardiovascular differentiation. We used a multiplex microfluidic array, which overcomes the limitations of macroperfusion systems in shear application throughput and precision, to initiate a comprehensive, quantitative study of shear effects on self-renewing mouse embryonic stem cells (mESCs), where shear stresses varying by >1000 times (0.016–16 dyn/cm2) are applied simultaneously. When compared with static controls in the presence or absence of a saturated soluble environment (i.e., mESC-conditioned medium), we ascertained that flow-induced shear stress specifically up-regulates the epiblast marker Fgf5. Epiblast-state transition in mESCs involves heparan sulfate proteoglycans (HSPGs), which have also been shown to transduce shear stress in endothelial cells. By disrupting (with sulfation inhibitors and heparinase) and partially reconstituting (with heparin) HSPG function, we show that mESCs also mechanically sense shear stress via HSPGs to modulate Fgf5 expression. This study demonstrates that self-renewing mESCs possess the molecular machinery to sense shear stress and provides quantitative shear application benchmarks for future scalable stem cell culture systems.—Toh, Y.-C., Voldman, J. Fluid shear stress primes mouse embryonic stem cells for differentiation in a self-renewing environment via heparan sulfate proteoglycans transduction. PMID:21183594
Smith, Sean G; Griffith, Boyce E; Zaharoff, David A
2018-04-05
Ailments of the bladder are often treated via intravesical delivery-direct application of therapeutic into the bladder through a catheter. This technique is employed hundreds of thousands of times every year, but protocol development has largely been limited to empirical determination. Furthermore, the numerical analyses of intravesical delivery performed to date have been restricted to static geometries and have not accounted for bladder deformation. This study uses a finite element analysis approach with biphasic solute transport to investigate several parameters pertinent to intravesical delivery including solute concentration, solute transport properties and instillation volume. The volume of instillation was found to have a substantial impact on the exposure of solute to the deeper muscle layers of the bladder, which are typically more difficult to reach. Indeed, increasing the instillation volume from 50-100 ml raised the muscle solute exposure as a percentage of overall bladder exposure from 60-70% with higher levels achieved for larger instillation volumes. Similar increases were not seen for changes in solute concentration or solute transport properties. These results indicate the role that instillation volume may play in targeting particular layers of the bladder during an intravesical delivery.
Dynamics and statics of nonaxisymmetric liquid bridges
NASA Technical Reports Server (NTRS)
Alexander, J. Iwan D.; Resnick, Andy; Zhang, Yiqiang; Fedoseyev, A.
1994-01-01
We finished the construction of the experimental apparatus and the design and testing of some of the visualization and data acquisition techniques. Experimental work focused on three areas: force measurements, loss of stability to nonaxisymmetric bridges, and vibration behavior. The experimental work is summarized in section 2. Selected results from our force measurement experiments are outlined in section 3. In addition we worked on the theory of the dynamic stability of axisymmetric bridges and undertook numerical simulation of the effects of inclined gravity vectors on the minimum volume stability limit for static bridges. The results and status of our theoretical work and numerical simulation are described in section 4. Papers published and in preparation, conference presentations, etc., are described in section 5. Work planned for the third year is discussed in section 6. References cited in the report are listed in section 7.
NASA Technical Reports Server (NTRS)
Allen, E. C.; Tuttle, T.
1973-01-01
Static stability and control effectiveness characteristics of two 0.004 scale models of the vehicle 3 configuration are reported. The components investigated consisted of a single aft body, vertical/rudder, OMS pods with two interchangeable wings, four interchangeable forward bodies, four trimmers, and a spoiler. The test was conducted in 14 x 14 inch trisonic wind tunnel over a Mach number range from 0.6 to 4.96. Angles of attack from 0 to 60 degrees and angles of sideslip from -10 to 10 degrees at 0, 10, 20,30, and 40 degrees angle of attack were tested. Elevon, body flap, and speed brake deflection composed the parametric considerations. No grit was placed on the models during the test. The tabulated source data and incremental data figures are presented.
NASA Technical Reports Server (NTRS)
Yamamoto, K.; Janardan, B. A.; Brausch, J. F.; Hoerst, D. J.; Price, A. O.
1984-01-01
Parameters which contribute to supersonic jet shock noise were investigated for the purpose of determining means to reduce such noise generation to acceptable levels. Six dual-stream test nozzles with varying flow passage and plug closure designs were evaluated under simulated flight conditions in an anechoic chamber. All nozzles had combined convergent-divergent or convergent flow passages. Mean velocity and turbulence velocity measurements of 25 selected flow conditions were performed employing a laser Doppler velocimeter. Static pressure measurements were made to define the actual convergence-divergence condition. Test point definition, tabulation of aerodynamic test conditions, velocity histograms, and shadowgraph photographs are presented. Flow visualization through shadowgraph photography can contribute to the development of an analytical prediction model for shock noise from coannular plug nozzles.
The Role of Representation Strength of the Prime in Subliminal Visuomotor Priming.
Wang, Yongchun; Wang, Yonghui; Liu, Peng; Di, Meilin; Gong, Yanyan; Tan, Mengge
2017-11-01
This study investigated the role of representation strength of the prime in subliminal visuomotor priming in two experiments. Prime/target compatibility (compatible and incompatible) and preposed object type (jumbled lines, strong masking; and rectangular outlines, weak masking) were manipulated in Experiment 1. A significant negative compatibility effect (NCE) was observed in the rectangle condition, whereas no compatibility effect was found in the line condition. However, when a new variable, prime duration, was introduced in Experiment 2, the NCE was reversed with an increase in the prime duration in the rectangle condition, whereas the NCE was maintained in the line condition. This result is consistent with the claim that increasing the prime duration causes the prime representation to be too strong for inhibition in the rectangle condition but strong enough to reliably trigger inhibition in the line condition. The findings demonstrated that prime representation has a causal role in subliminal visuomotor priming.
The effects of priming on children's attitudes toward older individuals.
Hoe, Sony; Davidson, Denise
2002-01-01
The purpose of the present research was to examine younger (7-years-old) and older (10-years-old) children's attitudes toward older individuals following one type of five primes: positive prime, negative prime, elderly prime, grandparent prime, or neutral prime. Overall, children's attitudes on three tests--Apperception, Semantic Differential, and Attribute Salience--were affected by the type of prime children were given, with positive and grandparent primes resulting in more positive views toward older individuals than negative, elderly, or neutral (control group) primes. The present research provides evidence that priming the most accessible cognitions about an individual can affect even young children's perception of the individual. These results are discussed in terms of category-based and data-driven processing and may explain the disparate findings obtained in previous studies that have shown the children's attitudes toward older individuals are sometimes negative, whereas other studies have shown that children's attitudes are more positive or neutral.
Sequential Stereotype Priming: A Meta-Analysis.
Kidder, Ciara K; White, Katherine R; Hinojos, Michelle R; Sandoval, Mayra; Crites, Stephen L
2017-08-01
Psychological interest in stereotype measurement has spanned nearly a century, with researchers adopting implicit measures in the 1980s to complement explicit measures. One of the most frequently used implicit measures of stereotypes is the sequential priming paradigm. The current meta-analysis examines stereotype priming, focusing specifically on this paradigm. To contribute to ongoing discussions regarding methodological rigor in social psychology, one primary goal was to identify methodological moderators of the stereotype priming effect-whether priming is due to a relation between the prime and target stimuli, the prime and target response, participant task, stereotype dimension, stimulus onset asynchrony (SOA), and stimuli type. Data from 39 studies yielded 87 individual effect sizes from 5,497 participants. Analyses revealed that stereotype priming is significantly moderated by the presence of prime-response relations, participant task, stereotype dimension, target stimulus type, SOA, and prime repetition. These results carry both practical and theoretical implications for future research on stereotype priming.
Lupker, Stephen J.
2017-01-01
The experiments reported here used “Reversed-Interior” (RI) primes (e.g., cetupmor-COMPUTER) in three different masked priming paradigms in order to test between different models of orthographic coding/visual word recognition. The results of Experiment 1, using a standard masked priming methodology, showed no evidence of priming from RI primes, in contrast to the predictions of the Bayesian Reader and LTRS models. By contrast, Experiment 2, using a sandwich priming methodology, showed significant priming from RI primes, in contrast to the predictions of open bigram models, which predict that there should be no orthographic similarity between these primes and their targets. Similar results were obtained in Experiment 3, using a masked prime same-different task. The results of all three experiments are most consistent with the predictions derived from simulations of the Spatial-coding model. PMID:29244824
The Shock and Vibration Digest. Volume 18, Number 1
1986-01-01
polyurethanes reduced the loss factor and emphasized the correlation between molecular storage modulus by increasing the length of the structure and...one tempera- static deformations. He gave storage and loss ture/frequency range is difficult with copoly- moduli for a carbon black filled and an...has been described (18). The shear loss author states that the frequency dependence of and storage moduli of a void-filled polyurethane the elastomers
Perturbative two- and three-loop coefficients from large β Monte Carlo
NASA Astrophysics Data System (ADS)
Lepage, G. P.; Mackenzie, P. B.; Shakespeare, N. H.; Trottier, H. D.
Perturbative coefficients for Wilson loops and the static quark self-energy are extracted from Monte Carlo simulations at large β on finite volumes, where all the lattice momenta are large. The Monte Carlo results are in excellent agreement with perturbation theory through second order. New results for third order coefficients are reported. Twisted boundary conditions are used to eliminate zero modes and to suppress Z3 tunneling.
2011-08-01
Standardization Agency, "Procedures For Evaluating the Protection Level of Logistic and Light Armoured Vehicles", NATO/PfP STANAG 4569, AEP- 55, Volume 2, 2006...not be used for advertising or product endorsement purposes. 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 Az Center Blast Static
Manufacturing Diamond Under Very High Pressure
NASA Technical Reports Server (NTRS)
Voronov, Oleg
2007-01-01
A process for manufacturing bulk diamond has been made practical by the invention of the High Pressure and Temperature Apparatus capable of applying the combination of very high temperature and high pressure needed to melt carbon in a sufficiently large volume. The apparatus includes a reaction cell wherein a controlled static pressure as high as 20 GPa and a controlled temperature as high as 5,000 C can be maintained.
Perturbative two- and three-loop coefficients from large b Monte Carlo
DOE Office of Scientific and Technical Information (OSTI.GOV)
G.P. Lepage; P.B. Mackenzie; N.H. Shakespeare
1999-10-18
Perturbative coefficients for Wilson loops and the static quark self-energy are extracted from Monte Carlo simulations at large {beta} on finite volumes, where all the lattice momenta are large. The Monte Carlo results are in excellent agreement with perturbation theory through second order. New results for third order coefficients are reported. Twisted boundary conditions are used to eliminate zero modes and to suppress Z{sub 3} tunneling.
Synchronous meteorological satellite system description document, volume 3
NASA Technical Reports Server (NTRS)
Pipkin, F. B.
1971-01-01
The structural design, analysis, and mechanical integration of the synchronous meteorological satellite system are presented. The subjects discussed are: (1) spacecraft configuration, (2) structural design, (3) static load tests, (4) fixed base sinusoidal vibration survey, (5) flight configuration sinusoidal vibration tests, (6) spacecraft acoustic test, and (7) separation and shock test. Descriptions of the auxiliary propulsion subsystem, the apogee boost motor, communications system, and thermal control subsystem are included.
Updated Chemical Kinetics and Sensitivity Analysis Code
NASA Technical Reports Server (NTRS)
Radhakrishnan, Krishnan
2005-01-01
An updated version of the General Chemical Kinetics and Sensitivity Analysis (LSENS) computer code has become available. A prior version of LSENS was described in "Program Helps to Determine Chemical-Reaction Mechanisms" (LEW-15758), NASA Tech Briefs, Vol. 19, No. 5 (May 1995), page 66. To recapitulate: LSENS solves complex, homogeneous, gas-phase, chemical-kinetics problems (e.g., combustion of fuels) that are represented by sets of many coupled, nonlinear, first-order ordinary differential equations. LSENS has been designed for flexibility, convenience, and computational efficiency. The present version of LSENS incorporates mathematical models for (1) a static system; (2) steady, one-dimensional inviscid flow; (3) reaction behind an incident shock wave, including boundary layer correction; (4) a perfectly stirred reactor; and (5) a perfectly stirred reactor followed by a plug-flow reactor. In addition, LSENS can compute equilibrium properties for the following assigned states: enthalpy and pressure, temperature and pressure, internal energy and volume, and temperature and volume. For static and one-dimensional-flow problems, including those behind an incident shock wave and following a perfectly stirred reactor calculation, LSENS can compute sensitivity coefficients of dependent variables and their derivatives, with respect to the initial values of dependent variables and/or the rate-coefficient parameters of the chemical reactions.
Hofmann, Melanie; Winzer, Matthias; Weber, Christian; Gieseler, Henning
2016-06-01
The development of highly concentrated protein formulations is more demanding than for conventional concentrations due to an elevated protein aggregation tendency. Predictive protein-protein interaction parameters, such as the second virial coefficient B22 or the interaction parameter kD, have already been used to predict aggregation tendency and optimize protein formulations. However, these parameters can only be determined in diluted solutions, up to 20 mg/mL. And their validity at high concentrations is currently controversially discussed. This work presents a μ-scale screening approach which has been adapted to early industrial project needs. The procedure is based on static light scattering to directly determine protein-protein interactions at concentrations up to 100 mg/mL. Three different therapeutic molecules were formulated, varying in pH, salt content, and addition of excipients (e.g., sugars, amino acids, polysorbates, or other macromolecules). Validity of the predicted aggregation tendency was confirmed by stability data of selected formulations. Based on the results obtained, the new prediction method is a promising screening tool for fast and easy formulation development of highly concentrated protein solutions, consuming only microliter of sample volumes. Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Radhakrishnan, Krishnan
1994-01-01
LSENS, the Lewis General Chemical Kinetics and Sensitivity Analysis Code, has been developed for solving complex, homogeneous, gas-phase chemical kinetics problems and contains sensitivity analysis for a variety of problems, including nonisothermal situations. This report is part 1 of a series of three reference publications that describe LENS, provide a detailed guide to its usage, and present many example problems. Part 1 derives the governing equations and describes the numerical solution procedures for the types of problems that can be solved. The accuracy and efficiency of LSENS are examined by means of various test problems, and comparisons with other methods and codes are presented. LSENS is a flexible, convenient, accurate, and efficient solver for chemical reaction problems such as static system; steady, one-dimensional, inviscid flow; reaction behind incident shock wave, including boundary layer correction; and perfectly stirred (highly backmixed) reactor. In addition, the chemical equilibrium state can be computed for the following assigned states: temperature and pressure, enthalpy and pressure, temperature and volume, and internal energy and volume. For static problems the code computes the sensitivity coefficients of the dependent variables and their temporal derivatives with respect to the initial values of the dependent variables and/or the three rate coefficient parameters of the chemical reactions.
Lattice vibrational contribution to equation of state for tetrahedral compounds
NASA Astrophysics Data System (ADS)
Kagaya, H.-Matsuo; Kotoku, H.; Soma, T.
1989-02-01
The lattice vibrational contributions to the Helmholtz free energy and the thermal pressure of tetrahedral compounds such as GaP, InP, ZnS, ZnSe, ZnTe and CdTe are investigated from the electronic theory of solids in the dynamical treatment based on our presented binding force. The temperature dependence of Helmholtz free energy and thermal pressure from lattice vibrational term are quantitatively obtained, and vibrational contributions to free energy are small compared with the static crystal energy. The influence of the thermal pressure is important to the equation of state in high temperatures, and the reformulation of the volume scale for the pressure-volume relation is given by considering the thermal pressure.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perez-Andujar, A; Cheung, J; Chuang, C
Purpose: To investigate the effect of dynamic and static jaw tracking on patient peripheral doses. Materials and Methods: A patient plan with a large sacral metastasis (volume 800cm3, prescription 600cGyx5) was selected for this study. The plan was created using 2-field RapidArc with jaw tracking enabled (Eclipse, V11.0.31). These fields were then exported and edited in MATLAB with static jaw positions using the control point with the largest field size for each respective arc, but preserving the optimized leaf sequences for delivery. These fields were imported back into Eclipse for dose calculation and comparison and copied to a Rando phantommore » for delivery analysis. Points were chosen in the phantom at depth and on the phantom surface at locations outside the primary radiation field, at distances of 12cm, 20cm, and 30cm from the isocenter. Measurements were acquired with OSLDs placed at these positions in the phantom with both the dynamic and static jaw deliveries for comparison. Surface measurements included an additional 1cm bolus over the OSLDs to ensure electron equilibrium. Results: The static jaw deliveries resulted in cumulative jaw-defined field sizes of 17.3% and 17.4% greater area than the dynamic jaw deliveries for each arc. The static jaw plan resulted in very small differences in calculated dose in the treatment planning system ranging from 0–16cGy. The measured dose differences were larger than calculated, but the differences in absolute dose were small. The measured dose differences at depth (surface) between the two deliveries showed an increase for the static jaw delivery of 2.2%(11.4%), 15.6%(20.0%), and 12.7%(12.7%) for distances of 12cm, 20cm, and 30cm, respectively. Eclipse calculates a difference of 0–3.1% for all of these points. The largest absolute dose difference between all points was 6.2cGy. Conclusion: While we demonstrated larger than expected differences in peripheral dose, the absolute dose differences were small.« less
Schoolbook Texts: Behavioral Achievement Priming in Math and Language.
Engeser, Stefan; Baumann, Nicola; Baum, Ingrid
2016-01-01
Prior research found reliable and considerably strong effects of semantic achievement primes on subsequent performance. In order to simulate a more natural priming condition to better understand the practical relevance of semantic achievement priming effects, running texts of schoolbook excerpts with and without achievement primes were used as priming stimuli. Additionally, we manipulated the achievement context; some subjects received no feedback about their achievement and others received feedback according to a social or individual reference norm. As expected, we found a reliable (albeit small) positive behavioral priming effect of semantic achievement primes on achievement in math (Experiment 1) and language tasks (Experiment 2). Feedback moderated the behavioral priming effect less consistently than we expected. The implication that achievement primes in schoolbooks can foster performance is discussed along with general theoretical implications.
Schoolbook Texts: Behavioral Achievement Priming in Math and Language
Engeser, Stefan; Baumann, Nicola; Baum, Ingrid
2016-01-01
Prior research found reliable and considerably strong effects of semantic achievement primes on subsequent performance. In order to simulate a more natural priming condition to better understand the practical relevance of semantic achievement priming effects, running texts of schoolbook excerpts with and without achievement primes were used as priming stimuli. Additionally, we manipulated the achievement context; some subjects received no feedback about their achievement and others received feedback according to a social or individual reference norm. As expected, we found a reliable (albeit small) positive behavioral priming effect of semantic achievement primes on achievement in math (Experiment 1) and language tasks (Experiment 2). Feedback moderated the behavioral priming effect less consistently than we expected. The implication that achievement primes in schoolbooks can foster performance is discussed along with general theoretical implications. PMID:26938446
Being forward not backward: lexical limits to masked priming.
Davis, Chris; Kim, Jeesun; Forster, Kenneth I
2008-05-01
This study investigated whether masked priming is mediated by existing memory representations by determining whether nonwords targets would show repetition priming. To avoid the potential confound that nonword repetition priming would be obscured by a familiarity response bias, the standard lexical decision and naming tasks were modified to make targets unfamiliar. Participants were required to read a target string from right to left (i.e., "ECAF" should be read as "FACE") and then make a response. To examine if priming was based on lexical representations, repetition primes consisted of words when read forwards or backwards (e.g., "face", "ecaf") and nonwords (e.g., "pame", "emap"). Forward and backward primes were used to test if task instruction affected prime encoding. The lexical decision and naming tasks showed the same pattern of results: priming only occurred for forward primes with word targets (e.g., "face-ECAF"). Additional experiments to test if response priming affected the LDT indicated that the lexical status of the prime per se did not affect target responses. These results showed that the encoding of masked primes was unaffected by the novel task instruction and support the view that masked priming is due to the automatic triggering of pre-established computational processes based on stored information.
Scharlau, Ingrid; Neumann, Odmar
2003-08-01
Four experiments investigated the influence of a metacontrast-masked prime on temporal order judgments. The main results were (1) that a masked prime reduced the latency of the mask's conscious perception (perceptual latency priming), (2) that this effect was independent of whether the prime suffered strong or weak masking, (3) that it was unaffected by the degree of visual similarity between the prime and the mask, and that (4) there was no difference between congruent and incongruent primes. Finding (1) suggests that location cueing affects not only response times but also the latency of conscious perception. (2) The finding that priming was unaffected by the prime's detectability argues against a response bias interpretation of this effect. (3) Since visual similarity had no effect on the prime's efficiency, it is unlikely that sensory priming was involved. (4) The lack of a divergence between the effects of congruent and incongruent primes implies a functional difference between the judgments in the temporal order judgment task and speeded responses that have demonstrated differential effects of congruent and incongruent primes (e.g., Klotz & Neumann, 1999). These results can best be interpreted by assuming that the prime affects perceptual latency by initiating a shift of attention, as suggested by the Asynchronous Updating Model (AUM; Neumann 1978, 1982).
NASA Technical Reports Server (NTRS)
Ferris, James P.; KAMALUDDIN; Ertem, Gozen
1990-01-01
The 2(prime)-d-5(prime)-GMP and 2(prime)-d-5(prime)-AMP bind 2 times more strongly to montmorillonite 22A than do 2(prime)-d-5(prime)-CMP and 5(prime)-TMP. The dinucleotide d(pG)2 forms in 9.2 percent yield and the cyclic dinucleotide c(dpG)2 in 5.4 percent yield in the reaction of 2(prime)-d-5(prime)-GMP with EDAC in the presence of montmorillonite 22A. The yield of dimers which contain the phosphodiester bond decreases as the reaction medium is changed from 0.2 M NaCl to a mixture of 0.2 M NaCl and 0.075 M MgCl2. A low yield of d(pA)2 was observed in the condensation reaction of 5(prime)-ImdpA on montmorillonite 22A. The yield of d(pA)2 obtained when EDAC is used as the condensing agent increases with increasing iron content of the Na(+)-montmorillonite used as catalyst. Evidence is presented which shows that the acidity of the Na(+)-montmorillonite is a necessary but not sufficient factor for the montmorillonite catalysis of phosphodiester bond formation.
McMenamin, Brenton W.; Deason, Rebecca G.; Steele, Vaughn R.; Koutstaal, Wilma; Marsolek, Chad J.
2014-01-01
Previous research indicates that dissociable neural subsystems underlie abstract-category (AC) recognition and priming of objects (e.g., cat, piano) and specific-exemplar (SE) recognition and priming of objects (e.g., a calico cat, a different calico cat, a grand piano, etc.). However, the degree of separability between these subsystems is not known, despite the importance of this issue for assessing relevant theories. Visual object representations are widely distributed in visual cortex, thus a multivariate pattern analysis (MVPA) approach to analyzing functional magnetic resonance imaging (fMRI) data may be critical for assessing the separability of different kinds of visual object processing. Here we examined the neural representations of visual object categories and visual object exemplars using multi-voxel pattern analyses of brain activity elicited in visual object processing areas during a repetition-priming task. In the encoding phase, participants viewed visual objects and the printed names of other objects. In the subsequent test phase, participants identified objects that were either same-exemplar primed, different-exemplar primed, word-primed, or unprimed. In visual object processing areas, classifiers were trained to distinguish same-exemplar primed objects from word-primed objects. Then, the abilities of these classifiers to discriminate different-exemplar primed objects and word-primed objects (reflecting AC priming) and to discriminate same-exemplar primed objects and different-exemplar primed objects (reflecting SE priming) was assessed. Results indicated that (a) repetition priming in occipital-temporal regions is organized asymmetrically, such that AC priming is more prevalent in the left hemisphere and SE priming is more prevalent in the right hemisphere, and (b) AC and SE subsystems are weakly modular, not strongly modular or unified. PMID:25528436
McMenamin, Brenton W; Deason, Rebecca G; Steele, Vaughn R; Koutstaal, Wilma; Marsolek, Chad J
2015-02-01
Previous research indicates that dissociable neural subsystems underlie abstract-category (AC) recognition and priming of objects (e.g., cat, piano) and specific-exemplar (SE) recognition and priming of objects (e.g., a calico cat, a different calico cat, a grand piano, etc.). However, the degree of separability between these subsystems is not known, despite the importance of this issue for assessing relevant theories. Visual object representations are widely distributed in visual cortex, thus a multivariate pattern analysis (MVPA) approach to analyzing functional magnetic resonance imaging (fMRI) data may be critical for assessing the separability of different kinds of visual object processing. Here we examined the neural representations of visual object categories and visual object exemplars using multi-voxel pattern analyses of brain activity elicited in visual object processing areas during a repetition-priming task. In the encoding phase, participants viewed visual objects and the printed names of other objects. In the subsequent test phase, participants identified objects that were either same-exemplar primed, different-exemplar primed, word-primed, or unprimed. In visual object processing areas, classifiers were trained to distinguish same-exemplar primed objects from word-primed objects. Then, the abilities of these classifiers to discriminate different-exemplar primed objects and word-primed objects (reflecting AC priming) and to discriminate same-exemplar primed objects and different-exemplar primed objects (reflecting SE priming) was assessed. Results indicated that (a) repetition priming in occipital-temporal regions is organized asymmetrically, such that AC priming is more prevalent in the left hemisphere and SE priming is more prevalent in the right hemisphere, and (b) AC and SE subsystems are weakly modular, not strongly modular or unified. Copyright © 2014 Elsevier Inc. All rights reserved.
Space-valence priming with subliminal and supraliminal words.
Ansorge, Ulrich; Khalid, Shah; König, Peter
2013-01-01
To date it is unclear whether (1) awareness-independent non-evaluative semantic processes influence affective semantics and whether (2) awareness-independent affective semantics influence non-evaluative semantic processing. In the current study, we investigated these questions with the help of subliminal (masked) primes and visible targets in a space-valence across-category congruence effect. In line with (1), we found that subliminal space prime words influenced valence classification of supraliminal target words (Experiment 1): classifications were faster with a congruent prime (e.g., the prime "up" before the target "happy") than with an incongruent prime (e.g., the prime "up" before the target "sad"). In contrast to (2), no influence of subliminal valence primes on the classification of supraliminal space targets into up- and down-words was found (Experiment 2). Control conditions showed that standard masked response priming effects were found with both subliminal prime types, and that an across-category congruence effect was also found with supraliminal valence primes and spatial target words. The final Experiment 3 confirmed that the across-category congruence effect indeed reflected priming of target categorization of a relevant meaning category. Together, the data jointly confirmed prediction (1) that awareness-independent non-evaluative semantic priming influences valence judgments.
The energy structure and decay channels of the 4p6-shell excited states in Sr
NASA Astrophysics Data System (ADS)
Kupliauskienė, A.; Kerevičius, G.; Borovik, V.; Shafranyosh, I.; Borovik, A.
2017-11-01
The ejected-electron spectra arising from the decay of the 4p{}5{{nln}}{\\prime }{l}{\\prime }{n}{\\prime\\prime }{l}{\\prime\\prime } autoionizing states in Sr atoms have been studied precisely at the incident-electron energies close to excitation and ionization thresholds of the 4{{{p}}}6 subshell. The excitation behaviors for 58 lines observed between 12 and 21 eV ejected-electron kinetic energy have been investigated. Also, the ab initio calculations of excitation energies, autoionization probabilities and electron-impact excitation cross sections of the states 4p{}5{{nln}}{\\prime }{l}{\\prime }{n}{\\prime\\prime }{l}{\\prime\\prime } (nl = 4d, 5s, 5p; {n}{\\prime }{l}{\\prime } = 4d, 5s, 5p; {n}{\\prime\\prime }{l}{\\prime\\prime } = 5s, 6s, 7s, 8s, 9s, 5p, 6p, 5d, 6d, 7d, 8d, 4f, 5g) have been performed by employing the large-scale configuration-interaction method in the basis of the solutions of Dirac-Fock-Slater equations. The obtained experimental and theoretical data have been used for the accurate identification of the 60 lines in ejected-electron spectra and the 68 lines observed earlier in photoabsorption spectra. The excitation and decay processes for 105 classified states in the 4p55s{}2{nl}, 4p54d{}2{nl} and 4p55s{{nln}}{\\prime }{l}{\\prime } configurations have been considered in detail. In particular, most of the states lying below the ionization threshold of the 4p6 subshell at 26.92 eV possess up to four decay channels with formation of Sr+ in 5s{}1/2, 4d{}3/{2,5/2} and 5p{}1/{2,3/2} states. Two-step autoionization and two-electron Auger transitions with formation of Sr2+ in the 4p6 {}1{{{S}}}0 ground state are the main decay paths for high-lying autoionizing states. The excitation threshold of the 4{{{p}}}6 subshell in Sr has been established at 20.98 ± 0.05 eV.
Hydro-chemical cycle of forest ecosystem in the Norikura Highlands
NASA Astrophysics Data System (ADS)
Muramoto, Michiko; Nara, Maiko; Asari, Tomoko; Suzuki, Keisuke
Because of precipitation serves as a major vehicle of nutrient input into the forest ecosystem, the accurate measurement of its volume and ion concentration is of prime importance in an evaluation of any bio-geochemical cycle. Therefore, chemistry of the precipitation and throughfall of forest ecosystem was investigated in the Norikura Highlands. The investigation period was from January, 2003 to October, 2006. The throughfall volume in growing season and dormant season were 86 % and 93 % of the precipitation volume. Throughfall pH increased with increasing K+ concentration showed that H+ was held within the canopy by cation exchange reaction. And the concentration level of K+, Mg2+ and Ca2+ in the throughfall was much higher than that in the precipitation. It was the cause of canopy leaching. In growing season, proportions of canopy leaching of K+, Mg2+ and Ca2+ were 95 %, 70 % and 43 % of the throughfall deposition respectively. At Coniferous site, the flux of dry deposition was higher in dormant season than growing season. It is suggested that aerosol of the atmosphere and leaf area might be influenced.
Inverse Target- and Cue-Priming Effects of Masked Stimuli
ERIC Educational Resources Information Center
Mattler, Uwe
2007-01-01
The processing of a visual target that follows a briefly presented prime stimulus can be facilitated if prime and target stimuli are similar. In contrast to these positive priming effects, inverse priming effects (or negative compatibility effects) have been found when a mask follows prime stimuli before the target stimulus is presented: Responses…
Associative priming in a masked perceptual identification task: evidence for automatic processes.
Pecher, Diane; Zeelenberg, René; Raaijmakers, Jeroen G W
2002-10-01
Two experiments investigated the influence of automatic and strategic processes on associative priming effects in a perceptual identification task in which prime-target pairs are briefly presented and masked. In this paradigm, priming is defined as a higher percentage of correctly identified targets for related pairs than for unrelated pairs. In Experiment 1, priming was obtained for mediated word pairs. This mediated priming effect was affected neither by the presence of direct associations nor by the presentation time of the primes, indicating that automatic priming effects play a role in perceptual identification. Experiment 2 showed that the priming effect was not affected by the proportion (.90 vs. .10) of related pairs if primes were presented briefly to prevent their identification. However, a large proportion effect was found when primes were presented for 1000 ms so that they were clearly visible. These results indicate that priming in a masked perceptual identification task is the result of automatic processes and is not affected by strategies. The present paradigm provides a valuable alternative to more commonly used tasks such as lexical decision.
Neely, J H; Keefe, D E; Ross, K L
1989-11-01
In semantic priming paradigms for lexical decisions, the probability that a word target is semantically related to its prime (the relatedness proportion) has been confounded with the probability that a target is a nonword, given that it is unrelated to its prime (the nonword ratio). This study unconfounded these two probabilities in a lexical decision task with category names as primes and with high- and low-dominance exemplars as targets. Semantic priming for high-dominance exemplars was modulated by the relatedness proportion and, to a lesser degree, by the nonword ratio. However, the nonword ratio exerted a stronger influence than did the relatedness proportion on semantic priming for low-dominance exemplars and on the nonword facilitation effect (i.e., the superiority in performance for nonword targets that follow a category name rather than a neutral XXX prime). These results suggest that semantic priming for lexical decisions is affected by both a prospective prime-generated expectancy, modulated by the relatedness proportion, and a retrospective target/prime semantic matching process, modulated by the nonword ratio.
Maximum static inspiratory and expiratory pressures with different lung volumes
Lausted, Christopher G; Johnson, Arthur T; Scott, William H; Johnson, Monique M; Coyne, Karen M; Coursey, Derya C
2006-01-01
Background Maximum pressures developed by the respiratory muscles can indicate the health of the respiratory system, help to determine maximum respiratory flow rates, and contribute to respiratory power development. Past measurements of maximum pressures have been found to be inadequate for inclusion in some exercise models involving respiration. Methods Maximum inspiratory and expiratory airway pressures were measured over a range of lung volumes in 29 female and 19 male adults. A commercial bell spirometry system was programmed to occlude airflow at nine target lung volumes ranging from 10% to 90% of vital capacity. Results In women, maximum expiratory pressure increased with volume from 39 to 61 cmH2O and maximum inspiratory pressure decreased with volume from 66 to 28 cmH2O. In men, maximum expiratory pressure increased with volume from 63 to 97 cmH2O and maximum inspiratory pressure decreased with volume from 97 to 39 cmH2O. Equations describing pressures for both sexes are: Pe/Pmax = 0.1426 Ln( %VC) + 0.3402 R2 = 0.95 Pi/Pmax = 0.234 Ln(100 - %VC) - 0.0828 R2 = 0.96 Conclusion These results were found to be consistent with values and trends obtained by other authors. Regression equations may be suitable for respiratory mechanics models. PMID:16677384
Temperature effect on mineralization of SOM, plant litter and priming: modified by soil type?
NASA Astrophysics Data System (ADS)
Azzaroli Bleken, Marina; Berland Frøseth, Randi
2015-04-01
The purpose of this study was to provide improved temperature response functions to be used in models of soil organic carbon (SOC) and litter mineralization, with focus on the winter period. Our working hypothesis were: 1) decomposition of SOM and plant residue occurs also at temperature close to the freezing point; 2) the effect of temperature on SOC decomposition is stronger in clayey than in sandy soil; 3) decomposition and response to temperature of added plant litter is not affected by soil type. A silty clay loam (27% clay, 3% sand) and a sandy loam (6% clay, 51% sand) with similar weather and cultivation history were pre-incubated at about 15° C for about 4.5 months. Clover leaves labelled with 13C were added to half of the samples, and soil with and without clover was incubated for 142 days at 0, 4, 8.5 or 15 °C. Mineralization of SOC and clover leaves was observed also at 0° C. In the absence of added plant material, SOC decomposition followed a first order reaction which was twice as fast in the sandy soil as in the clay soil. The decomposition rate of clover leaves was also higher in the sandy soil than in the clay soil. However, the influence of temperature on SOC and on clover decomposition was the same in both soils. In presence of plant material, there was a positive priming effect on SOC, which initially correlated with decomposition of plant litter. There was a progressively lower priming effect at higher temperatures, particularly in the sandy soil, that could be understood as substrates exhaustion in a restricted volume of influence around the added clover leaves. We provide parameterised Arrhenius and alternative modifying linear temperature functions together with decay rates at reference temperature, which can be used for predicting decay rates of SOC per se and of the labile pool of clover leaves. We also show the superiority of these functions compared to the use of Q10 as temperature factor. Further, we suggest approaches for modelling the priming effect caused by plant litter. Reference: Frøseth RB, Bleken MA(2015) Effect of low temperature and soil type on the decomposition rate of soil organic carbon and clover leaves, and related priming effect. Soil Biology and Biochemistry 80:156-166.
Petroleum marketing monthly, June 1994
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1994-06-01
The Petroleum Marketing Monthly (PMM) provides information and statistical data on a variety of crude oils and refined petroleum products. The publication presents statistics on crude oil costs and refined petroleum products sales for use by industry, government, private sector analysts, educational institutions, and consumers. Data on crude oil include the domestic first purchase price, the f.o.b. and landed cost of imported crude oil, and the refiners` acquisition cost of crude oil. Refined petroleum product sales data include motor gasoline, distillates, residuals, aviation fuels, kerosene, and propane. Monthly statistics on purchases of crude oil and sales of petroleum products aremore » presented in five sections: Summary Statistics; Crude Oil Prices; Prices of Petroleum Products; Volumes of Petroleum Products; and Prime Supplier Sales Volumes of Petroleum Products for Local Consumption. The feature article is entitled ``The Second Oxygenated Gasoline Season.`` 7 figs., 50 tabs.« less
Honjo, Osami; Mertens, Luc; Van Arsdell, Glen S
2011-01-01
Significant atrioventricular (AV) valve insufficiency in patient with single ventricle-physiology is strongly associated with poor survival. Herein we discuss the etiology and mechanism of development of significant AV valve insufficiency in patients with single-ventricle physiology, surgical indication and repair techniques, and clinical outcomes along with our 10-year surgical experience. Our recent clinical series and literature review indicate that it is of prime importance to appreciate the high incidence and clinical effect of the structural abnormalities of AV valve. Valve repair at stage II palliation may minimize the period of volume overload, thereby potentially preserving post-repair ventricular function. Since 85% of the AV valve insufficiency was associated with structural abnormalities, inspection of an AV valve that has more than mild to moderate insufficiency is recommended because they are not likely to be successfully treated with volume unloading surgery alone. Copyright © 2011 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Bart, Timothy J.; Kutler, Paul (Technical Monitor)
1998-01-01
Chapter 1 briefly reviews several related topics associated with the symmetrization of systems of conservation laws and quasi-conservation laws: (1) Basic Entropy Symmetrization Theory; (2) Symmetrization and eigenvector scaling; (3) Symmetrization of the compressible Navier-Stokes equations; and (4) Symmetrization of the quasi-conservative form of the magnetohydrodynamic (MHD) equations. Chapter 2 describes one of the best known tools employed in the study of differential equations, the maximum principle: any function f(x) which satisfies the inequality f(double prime)>0 on the interval [a,b] attains its maximum value at one of the endpoints on the interval. Chapter three examines the upwind finite volume schemes for scalar and system conservation laws. The basic tasks in the upwind finite volume approach have already been presented: reconstruction, flux evaluation, and evolution. By far, the most difficult task in this process is the reconstruction step.
Petroleum marketing monthly, February 1999 with data for November 1998
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1999-02-01
The Petroleum Marketing Monthly (PMM) provides information and statistical data on a variety of crude oils and refined petroleum products. The publication presents statistics on crude oil costs and refined petroleum products sales for use by industry, government, private sector analysts, educational institutions, and consumers. Data on crude oil include the domestic first purchase price, the f.o.b. and landed cost of imported crude oil, and the refiners` acquisition cost of crude oil. Refined petroleum product sales data include motor gasoline, distillates, residuals, aviation fuels, kerosene, and propane. Monthly statistics on purchases of crude oil and sales of petroleum products aremore » presented in the Petroleum Marketing Monthly in six sections: Initial Estimates; Summary Statistics; Crude Oil Prices; Prices of Petroleum Products; Volumes of Petroleum Products; and Prime Supplier Sales Volumes of Petroleum Products for Local Consumption. 7 figs., 50 tabs.« less
Petroleum marketing monthly, March 1999 with data for December 1998
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1999-03-01
The Petroleum Marketing Monthly (PMM) provides information and statistical data on a variety of crude oils and refined petroleum products. The publication presents statistics on crude oil costs and refined petroleum products sales for use by industry, government, private sector analysts, educational institutions, and consumers. Data on crude oil include the domestic first purchase price, the f.o.b. and landed cost of imported crude oil, and the refiners` acquisition cost of crude oil. Refined petroleum product sales data include motor gasoline, distillates, residuals, aviation fuels, kerosene, and propane. Monthly statistics on purchases of crude oil and sales of petroleum products aremore » presented in the Petroleum Marketing Monthly in five sections: summary statistics; crude oil prices; prices of petroleum products; volumes of petroleum products; and prime supplier sales volumes of petroleum products for local consumption. 7 figs., 50 tabs.« less
Microfluidics-based integrated airborne pathogen detection systems
NASA Astrophysics Data System (ADS)
Northrup, M. Allen; Alleman-Sposito, Jennifer; Austin, Todd; Devitt, Amy; Fong, Donna; Lin, Phil; Nakao, Brian; Pourahmadi, Farzad; Vinas, Mary; Yuan, Bob
2006-09-01
Microfluidic Systems is focused on building microfluidic platforms that interface front-end mesofluidics to handle real world sample volumes for optimal sensitivity coupled to microfluidic circuitry to process small liquid volumes for complex reagent metering, mixing, and biochemical analysis, particularly for pathogens. MFSI is the prime contractor on two programs for the US Department of Homeland Security: BAND (Bioagent Autonomous Networked Detector) and IBADS (Instantaneous Bio-Aerosol Detection System). The goal of BAND is to develop an autonomous system for monitoring the air for known biological agents. This consists of air collection, sample lysis, sample purification, detection of DNA, RNA, and toxins, and a networked interface to report the results. For IBADS, MFSI is developing the confirmatory device which must verify the presence of a pathogen with 5 minutes of an air collector/trigger sounding an alarm. Instrument designs and biological assay results from both BAND and IBADS will be presented.
Building a bone μCT images atlas for micro-architecture recognition
NASA Astrophysics Data System (ADS)
Freuchet, E.; Recur, B.; Guédon, Jp.; Kingston, A.; Autrusseau, F.; Amouriq, Y.
2015-03-01
Trabecular bone and its micro-architecture are of prime importance for health. Changes of bone micro-architecture are linked to different pathological situations like osteoporosis and begin now to be understood. In a previous paper, we started to investigate the relationships between bone and vessels and we also proposed to build a Bone Atlas. This study describes how to proceed for the elaboration and use of such an atlas. Here, we restricted the Atlas to legs (tibia, femur) of rats in order to work with well known geometry of the bone micro-architecture. From only 6 acquired bone, 132 trabecular bone volumes were generated using simple mathematical morphology tools. The variety and veracity of the created micro-architecture volumes is presented in this paper. Medical application and final goal would be to determinate bone micro-architecture with some angulated radiographs (3 or 4) and to easily diagnose the bone status (healthy, pathological or healing bone...).
An investigation of time course of category and semantic priming.
Ray, Suchismita
2008-04-01
Low semantically similar exemplars in a category demonstrate the category-priming effect through priming of the category (i.e., exemplar-category-exemplar), whereas high semantically similar exemplars in the same category demonstrate the semantic-priming effect (i.e., direct activation of one high semantically similar exemplar by another). The author asked whether the category- and semantic-priming effects are based on a common memory process. She examined this question by testing the time courses of category- and semantic-priming effects. She tested participants on either category- or semantic-priming paradigm at 2 different time intervals (6 min and 42 min) by using a lexical decision task using exemplars from categories. Results showed that the time course of category priming was different from that of semantic priming. The author concludes that these 2 priming effects are based on 2 separate memory processes.
PCB and DDE methyl sulfones in mammals from Canada and Sweden
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bergman, A.; Kuroki, Hiroaki; Norstrom, R.J.
1994-01-01
Levels of PCB methyl sulfones (MeSO[sub 2]-CBs) and DDE methyl sulfones (MeSO[sub 2]-DDEs) have been determined in tissues from polar bear (Ursus martimus), beluga whale (Delphinapterus leucas), and false killer whale (Pseudorca crassidens) from the Canadian environment, and grey seal (Halichoerus grypus), otter (Lutra lutra), and wild mink (Mustela vison) from the Swedish environment. Up to 30 MeSO[sub 2]-CB congeners and three MeSO[sub 2]-DdE isomers were shown to be present in the analyzed tissues. The concentration of total MeSO[sub 2]-CBs ranged from 0.1 to 21 [mu]g/g extracted lipids. 3-MeSO[sub 2]-2,5,2[prime],4[prime],5[prime]-penta-CB is the dominating MeSO[sub 2]-CB congener in all the analyzedmore » samples, but the corresponding 4-MeSO[sub 2]-CB also is present in high concentrations. A smaller number of MeSO[sub 2]-CBs, always dominated by the meta-substituted MeSO[sub 2]-CBs, were present in livers of grey seal, otter, and mink than in adipose tissue or muscle. In all studied mammals the concentration of MeSO[sub 2]-CBs were higher in liver than in blubber or muscle. Seven PCB congeners were identified as precursors of the PCB methyl sulfones: 2,4,2[prime],5[prime]-tetra-CB (CB-49),2,5,3[prime],4[prime]-tetra-CB (CB-70), 2,4,5,2[prime],5[prime]-penta-CB (CB-101),2,3,4,5,2[prime],5[prime]-penta-CB (CB-87),2,3,6,2[prime],4[prime],5[prime]-hexa-CB (CB-149),2,3,4,2[prime],3[prime],6[prime]-hexa-CB (CB-132), and 2,3,4,2[prime],5[prime]-hexa-CB (CB-141). All species except beluga whale contained 3-MeSO[sub 2]-4,4[prime]-DDE, but at a much lower concentration in mink and otter than in the other mammals. Polar bear and grey seal liver also contained 2-MeSO[sub 2]-4,4[prime]-DDE. The concentration of 2- and 3-MeSo[sub 2]-DDE ranged from 0.01 to 1.3 [mu]g/g extracted lipids.« less
Apparent diffusion coefficient measurement in a moving phantom simulating linear respiratory motion.
Kwee, Thomas C; Takahara, Taro; Muro, Isao; Van Cauteren, Marc; Imai, Yutaka; Nievelstein, Rutger A J; Mali, Willem P T M; Luijten, Peter R
2010-10-01
The aim of this study was to examine the effect of simulated linear respiratory motion on apparent diffusion coefficient (ADC) measurements. Six rectangular test tubes (14 × 92 mm) filled with either water, tomato ketchup, or mayonnaise were positioned in a box containing agarose gel. This box was connected to a double-acting pneumatic cylinder, capable of inducing periodic linear motion in the long-axis direction of the magnetic bore (23-mm stroke). Diffusion-weighted magnetic resonance imaging was performed for both the static and moving phantoms, and ADC measurements were made in the six test tubes in both situations. In the three test tubes whose long axes were parallel to the direction of motion, ADCs agreed well between the moving and static phantom situations. However, in two test tubes that were filled with fluids that had a considerably lower diffusion coefficient than the surrounding agarose gel, and whose long axes were perpendicular to the direction of motion, the ADCs agreed poorly between the moving and static phantom situations. ADC measurements of large homogeneous structures are not affected by linear respiratory motion. However, ADC measurements of inhomogeneous or small structures are affected by linear respiratory motion due to partial volume effects.
Thermal stability of static coronal loops: Part 1: Effects of boundary conditions
NASA Technical Reports Server (NTRS)
Antiochos, S. K.; Shoub, E. C.; An, C. H.; Emslie, A. G.
1985-01-01
The linear stability of static coronal-loop models undergoing thermal perturbations was investigated. The effect of conditions at the loop base on the stability properties of the models was considered in detail. The question of appropriate boundary conditions at the loop base was considered and it was concluded that the most physical assumptions are that the temperature and density (or pressure) perturbations vanish there. However, if the base is taken to be sufficiently deep in the chromosphere, either several chromospheric scale heights or several coronal loop lengths in depth, then the effect of the boundary conditions on loop stability becomes negligible so that all physically acceptable conditions are equally appropriate. For example, one could as well assume that the velocity vanishes at the base. The growth rates and eigenmodes of static models in which gravity is neglected and in which the coronal heating is a relatively simple function, either constant per-unit mass or per-unit volume were calculated. It was found that all such models are unstable with a growth rate of the order of the coronal cooling time. The physical implications of these results for the solar corona and transition region are discussed.
Pollitz, F.; Banerjee, P.; Grijalva, K.; Nagarajan, B.; Burgmann, R.
2008-01-01
The 2004 M=9.2 Sumatra-Andaman earthquake profoundly altered the state of stress in a large volume surrounding the ???1400 km long rupture. Induced mantle flow fields and coupled surface deformation are sensitive to the 3-D rheology structure. To predict the post-seismic motions from this earthquake, relaxation of a 3-D spherical viscoelastic earth model is simulated using the theory of coupled normal modes. The quasi-static deformation basis set and solution on the 3-D model is constructed using: a spherically stratified viscoelastic earth model with a linear stress-strain relation; an aspherical perturbation in viscoelastic structure; a 'static'mode basis set consisting of Earth's spheroidal and toroidal free oscillations; a "viscoelastic" mode basis set; and interaction kernels that describe the coupling among viscoelastic and static modes. Application to the 2004 Sumatra-Andaman earthquake illustrates the profound modification of the post-seismic flow field at depth by a slab structure and similarly large effects on the near-field post-seismic deformation field at Earth's surface. Comparison with post-seismic GPS observations illustrates the extent to which viscoelastic relaxation contributes to the regional post-seismic deformation. ?? Journal compilation ?? 2008 RAS.