Sample records for stationary source types

  1. Emission and profile characteristic of polycyclic aromatic hydrocarbons in PM2.5 and PM10 from stationary sources based on dilution sampling

    NASA Astrophysics Data System (ADS)

    Kong, Shaofei; Ji, Yaqin; Li, Zhiyong; Lu, Bing; Bai, Zhipeng

    2013-10-01

    The mass concentrations and profile characteristic for 18 kinds of polycyclic aromatic hydrocarbons (PAHs) in PM2.5 and PM10 from stack gases for six types of stationary sources in Shandong Province, China were studied by a dilution sampling system and GC-MS analysis method from February to March in 2010. The mass concentrations of PM2.5 and PM10 from the six types of stationary sources varied in 8.2-79.4 mg m-3 and 23.3-156.7 mg m-3, respectively. The total mass concentrations of analyzed PAHs in PM2.5 and PM10 were in the ranges of 0.40-94.35 μg m-3 and 9.16-122.91 μg m-3. The most toxic ashes were from sinter and coke oven for both PM2.5 and PM10 with high carcinogenic PAHs concentrations. BbF, Phe, NaP, BghiP, Pyr, BaP and BeP were abundant which was different from formers and one of the key reasons may be the differences of sampling methods. Diversities in PAHs compositions existed between fly ashes within PM2.5 and PM10 fractions for coke oven according to coefficient of divergence (CD) values. PAHs profiles for PM10 emitted from coke oven were different from those of other stationary sources (with CD values higher than 0.35) and for PM2.5, it was the same for sinter (with most CD values close to 0.30). There existed similar PAHs markers for fine particles emitted from stationary sources excepted for the sinter. For PM10, PAHs markers were primary 3-ring PAHs except for the coke oven with BbF, IND and BghiP as its signatures. Diagnostic ratios of BaA/(BaA + Chr), Flu/(Flu + Pyr), BaP/(BaP + BeP), BeP/BghiP and IND/(IND + BghiP) could be not well distinguished for the six types of stationary sources with the maximum/minimum ratios lower than 2 for both PM2.5 and PM10 of fly ashes which should be not used for source identification studies. The mass concentrations and source profiles of PAHs should be updated timely for size-differentiated fly ashes from various stationary sources by dilution sampling method.

  2. Sparse Bayesian Learning for Nonstationary Data Sources

    NASA Astrophysics Data System (ADS)

    Fujimaki, Ryohei; Yairi, Takehisa; Machida, Kazuo

    This paper proposes an online Sparse Bayesian Learning (SBL) algorithm for modeling nonstationary data sources. Although most learning algorithms implicitly assume that a data source does not change over time (stationary), one in the real world usually does due to such various factors as dynamically changing environments, device degradation, sudden failures, etc (nonstationary). The proposed algorithm can be made useable for stationary online SBL by setting time decay parameters to zero, and as such it can be interpreted as a single unified framework for online SBL for use with stationary and nonstationary data sources. Tests both on four types of benchmark problems and on actual stock price data have shown it to perform well.

  3. Air Pollution.

    EPA Science Inventory

    Air quality is affected by many types of pollutants that are emitted from various sources, including stationary and mobile. These sources release both criteria and hazardous air pollutants, which cause health effects, ecological harm, and material damage. They are generally categ...

  4. Basic Information about Air Emissions Monitoring

    EPA Pesticide Factsheets

    This site is about types of air emissions monitoring and the Clean Air Act regulations, including Ambient Air Quality Monitoring, Stationary Source Emissions Monitoring, and Continuous Monitoring Systems.

  5. 77 FR 26476 - Standards of Performance for Greenhouse Gas Emissions for New Stationary Sources: Electric...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-04

    ... Performance for Greenhouse Gas Emissions for New Stationary Sources: Electric Utility Generating Units AGENCY... Greenhouse Gas Emissions for New Stationary Sources: Electric Utility Generating Units.'' The EPA is making... for Greenhouse Gas Emissions for New Stationary Sources: Electric Utility Generating Units, and...

  6. 40 CFR Table 2c to Subpart Zzzz of... - Requirements for Existing Compression Ignition Stationary RICE Located at a Major Source of HAP...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Ignition Stationary RICE Located at a Major Source of HAP Emissions and Existing Spark Ignition Stationary RICE ⤠500 HP Located at a Major Source of HAP Emissions 2c Table 2c to Subpart ZZZZ of Part 63... Stationary RICE Located at a Major Source of HAP Emissions and Existing Spark Ignition Stationary RICE ≤ 500...

  7. (2+1)-dimensional stars

    NASA Astrophysics Data System (ADS)

    Lubo, M.; Rooman, M.; Spindel, Ph.

    1999-02-01

    We investigate, in the framework of (2+1)-dimensional gravity, stationary rotationally symmetric gravitational sources of the perfect fluid type, embedded in a space of an arbitrary cosmological constant. We show that the matching conditions between the interior and exterior geometries imply restrictions on the physical parameters of the solutions. In particular, imposing finite sources and the absence of closed timelike curves privileges negative values of the cosmological constant, yielding exterior vacuum geometries of rotating black hole type. In the special case of static sources, we prove the complete integrability of the field equations and show that the sources' masses are bounded from above and, for a vanishing cosmological constant, generally equal to 1. We also discuss and illustrate the stationary configurations by explicitly solving the field equations for constant mass-energy densities. If the pressure vanishes, we recover as interior geometries Gödel-like metrics defined on causally well behaved domains, but with unphysical values of the mass to angular momentum ratio. The introduction of pressure in the sources cures the latter problem and leads to physically more relevant models.

  8. Adaptation of Mycobacterium smegmatis to Stationary Phase

    PubMed Central

    Smeulders, Marjan J.; Keer, Jacquie; Speight, Richard A.; Williams, Huw D.

    1999-01-01

    Mycobacterium tuberculosis can persist for many years within host lung tissue without causing clinical disease. Little is known about the state in which the bacilli survive, although it is frequently referred to as dormancy. Some evidence suggests that cells survive in nutrient-deprived stationary phase. Therefore, we are studying stationary-phase survival of Mycobacterium smegmatis as a model for mycobacterial persistence. M. smegmatis cultures could survive 650 days of either carbon, nitrogen, or phosphorus starvation. In carbon-limited medium, cells entered stationary phase before the carbon source (glycerol) had been completely depleted and glycerol uptake from the medium continued during the early stages of stationary phase. These results suggest that the cells are able to sense when the glycerol is approaching limiting concentrations and initiate a shutdown into stationary phase, which involves the uptake of the remaining glycerol from the medium. During early stationary phase, cells underwent reductive cell division and became more resistant to osmotic and acid stress and pool mRNA stabilized. Stationary-phase cells were also more resistant to oxidative stress, but this resistance was induced during late exponential phase in a cell-density-dependent manner. Upon recovery in fresh medium, stationary-phase cultures showed an immediate increase in protein synthesis irrespective of culture age. Colony morphology variants accumulated in stationary-phase cultures. A flat colony variant was seen in 75% of all long-term-stationary-phase cultures and frequently took over the whole population. Cryo scanning electron microscopy showed that the colony organization was different in flat colony strains, flat colonies appearing less well organized than wild-type colonies. Competition experiments with an exponential-phase-adapted wild-type strain showed that the flat strain had a competitive advantage in stationary phase, as well a providing evidence that growth and cell division occur in stationary-phase cultures of M. smegmatis. These results argue against stationary-phase M. smegmatis cultures entering a quiescent state akin to dormancy but support the idea that they are a dynamic population of cells. PMID:9864340

  9. 40 CFR 52.460 - Small business stationary source technical and environmental compliance assistance program.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Small business stationary source... PLANS Delaware § 52.460 Small business stationary source technical and environmental compliance... Environmental Control submitted a plan for the establishment and implementation of a Small Business Stationary...

  10. 40 CFR 60.1715 - What types of continuous emission monitoring must I perform?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emission Guidelines... must I perform? To continuously monitor emissions, you must perform four tasks: (a) Install continuous...

  11. 75 FR 68296 - Standards of Performance for New Stationary Sources and Emission Guidelines for Existing Sources...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-05

    ... Standards of Performance for New Stationary Sources and Emission Guidelines for Existing Sources: Sewage... ``Standards of Performance for New Stationary Sources and Emission Guidelines for Existing Sources: Sewage... solid waste incineration units. In that action, EPA proposed NSPS and EG for sewage sludge incineration...

  12. 40 CFR 52.2586 - Small business stationary source technical and environmental compliance assistance program.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... PLANS (CONTINUED) Wisconsin § 52.2586 Small business stationary source technical and environmental compliance assistance program. The Wisconsin small business stationary source technical and environmental...

  13. 40 CFR 52.2586 - Small business stationary source technical and environmental compliance assistance program.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... PLANS (CONTINUED) Wisconsin § 52.2586 Small business stationary source technical and environmental compliance assistance program. The Wisconsin small business stationary source technical and environmental...

  14. 40 CFR 52.2586 - Small business stationary source technical and environmental compliance assistance program.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... PLANS (CONTINUED) Wisconsin § 52.2586 Small business stationary source technical and environmental compliance assistance program. The Wisconsin small business stationary source technical and environmental...

  15. 40 CFR 52.2586 - Small business stationary source technical and environmental compliance assistance program.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... PLANS (CONTINUED) Wisconsin § 52.2586 Small business stationary source technical and environmental compliance assistance program. The Wisconsin small business stationary source technical and environmental...

  16. 40 CFR 52.2586 - Small business stationary source technical and environmental compliance assistance program.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... PLANS (CONTINUED) Wisconsin § 52.2586 Small business stationary source technical and environmental compliance assistance program. The Wisconsin small business stationary source technical and environmental...

  17. 75 FR 26102 - Approval and Promulgation of Implementation Plans, State of California, San Joaquin Valley...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-11

    ... provide for review of new and modified stationary sources (``new source review'' or NSR) within the... the requirements and exemptions for review of new or modified stationary sources (``new source review... Modified Stationary 12/18/08 03/17/09 Source Review Rule. SJVUAPCD 2530 Federally Enforceable Potential 12...

  18. External split field generator

    DOEpatents

    Thundat, Thomas George [Knoxville, TN; Van Neste, Charles W [Kingston, TN; Vass, Arpad Alexander [Oak Ridge, TN

    2012-02-21

    A generator includes a coil disposed about a core. A first stationary magnetic field source may be disposed on a first end portion of the core and a second stationary magnetic field source may be disposed on a second end portion of core. The first and second stationary magnetic field sources apply a stationary magnetic field to the coil. An external magnetic field source may be disposed outside the coil to apply a moving magnetic field to the coil. Electrical energy is generated in response to an interaction between the coil, the moving magnetic field, and the stationary magnetic field.

  19. Adaptive CT scanning system

    DOEpatents

    Sampayan, Stephen E.

    2016-11-22

    Apparatus, systems, and methods that provide an X-ray interrogation system having a plurality of stationary X-ray point sources arranged to substantially encircle an area or space to be interrogated. A plurality of stationary detectors are arranged to substantially encircle the area or space to be interrogated, A controller is adapted to control the stationary X-ray point sources to emit X-rays one at a time, and to control the stationary detectors to detect the X-rays emitted by the stationary X-ray point sources.

  20. A Solar Stationary Type IV Radio Burst and Its Radiation Mechanism

    NASA Astrophysics Data System (ADS)

    Liu, Hongyu; Chen, Yao; Cho, Kyungsuk; Feng, Shiwei; Vasanth, Veluchamy; Koval, Artem; Du, Guohui; Wu, Zhao; Li, Chuanyang

    2018-04-01

    A stationary Type IV (IVs) radio burst was observed on September 24, 2011. Observations from the Nançay RadioHeliograph (NRH) show that the brightness temperature (TB) of this burst is extremely high, over 10^{11} K at 150 MHz and over 108 K in general. The degree of circular polarization (q) is between -60% ˜ -100%, which means that it is highly left-handed circularly polarized. The flux-frequency spectrum follows a power-law distribution, and the spectral index is considered to be roughly -3 ˜ -4 throughout the IVs. Radio sources of this event are located in the wake of the coronal mass ejection and are spatially dispersed. They line up to present a formation in which lower-frequency sources are higher. Based on these observations, it is suggested that the IVs was generated through electron cyclotron maser emission.

  1. Framework for Assessing Biogenic CO2 Emissions from Stationary Sources

    EPA Science Inventory

    This revision of the 2011 report, Accounting Framework for Biogenic CO2 Emissions from Stationary Sources, evaluates biogenic CO2 emissions from stationary sources, including a detailed study of the scientific and technical issues associated with assessing biogenic carbon dioxide...

  2. 77 FR 18709 - Quality Assurance Requirements for Continuous Opacity Monitoring Systems at Stationary Sources

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-28

    ... Quality Assurance Requirements for Continuous Opacity Monitoring Systems at Stationary Sources AGENCY... direct final rule titled ``Quality Assurance Requirements for Continuous Opacity Monitoring Systems at...--Quality Assurance Requirements for Continuous Opacity Monitoring Systems at Stationary Sources Docket, EPA...

  3. 40 CFR Table 2d to Subpart Zzzz of... - Requirements for Existing Compression Ignition Stationary RICE Located at Area Sources of HAP...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Ignition Stationary RICE Located at Area Sources of HAP Emissions 2d Table 2d to Subpart ZZZZ of Part 63... Stationary RICE Located at Area Sources of HAP Emissions As stated in §§ 63.6600 and 63.6640, you must comply with the following emission and operating limitations for existing compression ignition stationary RICE...

  4. The effect of spatial distribution on the annoyance caused by simultaneous sounds

    NASA Astrophysics Data System (ADS)

    Vos, Joos; Bronkhorst, Adelbert W.; Fedtke, Thomas

    2004-05-01

    A considerable part of the population is exposed to simultaneous and/or successive environmental sounds from different sources. In many cases, these sources are different with respect to their locations also. In a laboratory study, it was investigated whether the annoyance caused by the multiple sounds is affected by the spatial distribution of the sources. There were four independent variables: (1) sound category (stationary or moving), (2) sound type (stationary: lawn-mower, leaf-blower, and chain saw; moving: road traffic, railway, and motorbike), (3) spatial location (left, right, and combinations), and (4) A-weighted sound exposure level (ASEL of single sources equal to 50, 60, or 70 dB). In addition to the individual sounds in isolation, various combinations of two or three different sources within each sound category and sound level were presented for rating. The annoyance was mainly determined by sound level and sound source type. In most cases there were neither significant main effects of spatial distribution nor significant interaction effects between spatial distribution and the other variables. It was concluded that for rating the spatially distrib- uted sounds investigated, the noise dose can simply be determined by a summation of the levels for the left and right channels. [Work supported by CEU.

  5. CO2 EMISSIONS FROM BIOENERGY AND OTHER BIOGENIC SOURCES IN STATIONARY SOURCES

    EPA Science Inventory

    On January 12, 2011, EPA announced a series of steps to address the treatment of biogenic CO2 emissions from stationary sources, including a detailed study of the scientific and technical issues associated with accounting for biogenic carbon dioxide emissions from stationary sour...

  6. 40 CFR 52.744 - Small business stationary source technical and environmental compliance assistance program.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Small business stationary source technical and environmental compliance assistance program. 52.744 Section 52.744 Protection of Environment... PLANS Illinois> § 52.744 Small business stationary source technical and environmental compliance...

  7. 40 CFR 52.798 - Small business stationary source technical and environmental compliance assistance program.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Small business stationary source technical and environmental compliance assistance program. 52.798 Section 52.798 Protection of Environment... PLANS Indiana § 52.798 Small business stationary source technical and environmental compliance...

  8. 40 CFR Table 2b to Subpart Zzzz of... - Operating Limitations for New and Reconstructed 2SLB and Compression Ignition Stationary RICE...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Reconstructed 2SLB and Compression Ignition Stationary RICE >500 HP Located at a Major Source of HAP Emissions, New and Reconstructed 4SLB Stationary RICE â¥250 HP Located at a Major Source of HAP Emissions, Existing Compression Ignition Stationary RICE >500 HP, and Existing 4SLB Stationary RICE >500 HP Located at...

  9. 40 CFR Table 2c to Subpart Zzzz of... - Requirements for Existing Compression Ignition Stationary Rice Located at Major Sources of HAP...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., non-black start CI 500 HP a. Limit concentration of CO in the stationary RICE exhaust to 23 ppmvd or... Ignition Stationary Rice Located at Major Sources of HAP Emissions 2c Table 2c to Subpart ZZZZ of Part 63... Stationary Rice Located at Major Sources of HAP Emissions As stated in §§ 63.6600 and 63.6640, you must...

  10. 77 FR 44488 - Method 16C for the Determination of Total Reduced Sulfur Emissions From Stationary Sources

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-30

    ... Method 16C for the Determination of Total Reduced Sulfur Emissions From Stationary Sources AGENCY: Environmental Protection Agency (EPA). ACTION: Final rule. SUMMARY: This action promulgates Method 16C for measuring total reduced sulfur (TRS) emissions from stationary sources. Method 16C offers the advantages of...

  11. 40 CFR Table 3 to Subpart Zzzz of... - Subsequent Performance Tests

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... reconstructed 2SLB stationary RICE with a brake horsepower > 500 located at major sources; new or reconstructed 4SLB stationary RICE with a brake horsepower ≥ 250 located at major sources; and new or reconstructed CI stationary RICE with a brake horsepower > 500 located at major sources Reduce CO emissions and not...

  12. Solar Radiation on Mars: Tracking Photovoltaic Array

    NASA Technical Reports Server (NTRS)

    Appelbaum, Joseph; Flood, Dennis J.; Crutchik, Marcos

    1994-01-01

    A photovoltaic power source for surface-based operation on Mars can offer many advantages. Detailed information on solar radiation characteristics on Mars and the insolation on various types of collector surfaces are necessary for effective design of future planned photovoltaic systems. In this article we have presented analytical expressions for solar radiation calculation and solar radiation data for single axis (of various types) and two axis tracking surfaces and compared the insulation to horizontal and inclined surfaces. For clear skies (low atmospheric dust load) tracking surfaces resulted in higher insolation than stationary surfaces, whereas for highly dusty atmospheres, the difference is small. The insolation on the different types of stationary and tracking surfaces depend on latitude, season and optical depth of the atmosphere, and the duration of system operation. These insolations have to be compared for each mission.

  13. 40 CFR Table 1b to Subpart Zzzz of... - Operating Limitations for Existing, New, and Reconstructed Spark Ignition 4SRB Stationary RICE...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., and Reconstructed Spark Ignition 4SRB Stationary RICE >500 HP Located at a Major Source of HAP Emissions and Existing Spark Ignition 4SRB Stationary RICE >500 HP Located at an Area Source of HAP... Limitations for Existing, New, and Reconstructed Spark Ignition 4SRB Stationary RICE >500 HP Located at a...

  14. 40 CFR Table 1b to Subpart Zzzz of... - Operating Limitations for Existing, New, and Reconstructed Spark Ignition 4SRB Stationary RICE...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., New, and Reconstructed Spark Ignition 4SRB Stationary RICE >500 HP Located at a Major Source of HAP Emissions and Existing Spark Ignition 4SRB Stationary RICE >500 HP Located at an Area Source of HAP... Limitations for Existing, New, and Reconstructed Spark Ignition 4SRB Stationary RICE >500 HP Located at a...

  15. 40 CFR Table 1a to Subpart Zzzz of... - Emission Limitations for Existing, New, and Reconstructed Spark Ignition, 4SRB Stationary RICE...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., and Reconstructed Spark Ignition, 4SRB Stationary RICE > 500 HP Located at a Major Source of HAP... Limitations for Existing, New, and Reconstructed Spark Ignition, 4SRB Stationary RICE > 500 HP Located at a... stationary RICE >500 HP located at a major source of HAP emissions: For each . . . You must meet the...

  16. Exposure to infrasonic noise in agriculture.

    PubMed

    Bilski, Bartosz

    2017-03-21

    Although exposure to audible noise has been examined in many publications, the sources of infrasound in agriculture have not been fully examined and presented. The study presents the assessment of exposure to infrasound from many sources at workplaces in agriculture with examples of possible ergonomic and health consequences caused by such exposure. Workers'-perceived infrasonic noise levels were examined for 118 examples of moving and stationary agricultural machines (modern and old cab-type tractors, old tractors without cabins, small tractors, grinders, chargers, forage mixers, grain cleaners, conveyors, bark sorters and combine-harvesters). Measurements of infrasound were taken with the use of class 1 instruments (digital sound analyzer DSA-50 digital and acoustic calibrator). Noise level measurements were performed in accordance with PN-Z-01338:2010, PN-EN ISO 9612:2011 and ISO 9612:2009. The most intense sources of infrasound in the study were modern and old large size types agricultural machinery (tractors, chargers and combined-harvesters, and stationary forage mixers with ventilation). The G-weighted infrasound levels were significant and at many analyzed workplaces stayed within or exceeded the occupational exposure limit (LG eq, 8h = 102 dB) when the duration of exposure is longer than 22 min./8-hours working day (most noisy - modern cab-type tractors), 46 min./8 hours working day (most noisy - old type cab-tractors), 73 min./8 hours working day (most noisy - old tractors without cabins), 86 min./8-hours working day (most noisy - combine-harvesters) and 156 min./8 hours working day (most noisy - stationary forage mixers with ventilation). All measured machines generated infrasonic noise exceeded the value LG eq, Te = 86 dB (occupational exposure limit for workplaces requiring maintained mental concentration). A very important harmful factor is infrasound exposure for pregnant women and adolescents at workplaces in agriculture. Very valuable work can be technical limiting exposure to infrasound from new and used agricultural machinery. The technical limitation of infrasound caused by both old and new agricultural machinery can be invaluable from the work point of view.

  17. 40 CFR 60.1225 - What types of continuous emission monitoring must I perform?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Small Municipal Waste Combustion Units for Which Construction is Commenced After August 30... emissions, you must perform four tasks: (a) Install continuous emission monitoring systems for certain...

  18. Final Approval of Arizona Air Plan Revision; Stationary Sources; New Source Review; Ammonia

    EPA Pesticide Factsheets

    EPA is taking final action to approve a revision to a portion of the Arizona State Implementation Plan (SIP) concerning issuance of New Source Review (NSR) permits for stationary sources related to ammonia.

  19. 40 CFR Table 5 to Subpart Zzzz of... - Initial Compliance With Emission Limitations and Operating Limitations

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... demonstrated initial compliance if . . . 1. 2SLB and 4SLB stationary RICE >500 HP located at a major source and new or reconstructed CI stationary RICE >500 HP located at a major source a. Reduce CO emissions and... initial performance test. 2. 2SLB and 4SLB stationary RICE >500 HP located at a major source and new or...

  20. 40 CFR Table 5 to Subpart Zzzz of... - Initial Compliance With Emission Limitations and Operating Limitations

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... demonstrated initial compliance if . . . 1. New or reconstructed non-emergency 2SLB stationary RICE >500 HP located at a major source of HAP, new or reconstructed non-emergency 4SLB stationary RICE ≥250 HP located at a major source of HAP, non-emergency stationary CI RICE >500 HP located at a major source of HAP...

  1. Stationary Fuel Cell System Composite Data Products | Hydrogen and Fuel

    Science.gov Websites

    Capacity by Equipment Type CDP STAT 14, 10/21/15 Average Eligible Cost by Equipment Type, including Other Distributed Generation CDP STAT 15, 10/21/15 Average Eligible Cost for Biogas Sources CDP STAT 16, 10/21/15 Capacity and Eligible Cost (CHP Fuel Cells) CDP STAT 22, 10/21/15 Distribution of Eligible Cost with and

  2. [Sampling methods for PM2.5 from stationary sources: a review].

    PubMed

    Jiang, Jing-Kun; Deng, Jian-Guo; Li, Zhen; Li, Xing-Hua; Duan, Lei; Hao, Ji-Ming

    2014-05-01

    The new China national ambient air quality standard has been published in 2012 and will be implemented in 2016. To meet the requirements in this new standard, monitoring and controlling PM2,,5 emission from stationary sources are very important. However, so far there is no national standard method on sampling PM2.5 from stationary sources. Different sampling methods for PM2.5 from stationary sources and relevant international standards were reviewed in this study. It includes the methods for PM2.5 sampling in flue gas and the methods for PM2.5 sampling after dilution. Both advantages and disadvantages of these sampling methods were discussed. For environmental management, the method for PM2.5 sampling in flue gas such as impactor and virtual impactor was suggested as a standard to determine filterable PM2.5. To evaluate environmental and health effects of PM2.5 from stationary sources, standard dilution method for sampling of total PM2.5 should be established.

  3. 40 CFR Table 2d to Subpart Zzzz of... - Requirements for Existing Stationary RICE Located at Area Sources of HAP Emissions

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... RICE Located at Area Sources of HAP Emissions 2d Table 2d to Subpart ZZZZ of Part 63 Protection of... 2d Table 2d to Subpart ZZZZ of Part 63—Requirements for Existing Stationary RICE Located at Area... requirements for existing stationary RICE located at area sources of HAP emissions: For each . . . You must...

  4. 40 CFR Table 2b to Subpart Zzzz of... - Operating Limitations for New and Reconstructed 2SLB and Compression Ignition Stationary RICE...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Reconstructed 2SLB and Compression Ignition Stationary RICE >500 HP Located at a Major Source of HAP Emissions, Existing Non-Emergency Compression Ignition Stationary RICE >500 HP, and New and Reconstructed 4SLB Burn Stationary RICE â¥250 HP Located at a Major Source of HAP Emissions 2b Table 2b to Subpart ZZZZ of Part 63...

  5. Separation of non-stationary multi-source sound field based on the interpolated time-domain equivalent source method

    NASA Astrophysics Data System (ADS)

    Bi, Chuan-Xing; Geng, Lin; Zhang, Xiao-Zheng

    2016-05-01

    In the sound field with multiple non-stationary sources, the measured pressure is the sum of the pressures generated by all sources, and thus cannot be used directly for studying the vibration and sound radiation characteristics of every source alone. This paper proposes a separation model based on the interpolated time-domain equivalent source method (ITDESM) to separate the pressure field belonging to every source from the non-stationary multi-source sound field. In the proposed method, ITDESM is first extended to establish the relationship between the mixed time-dependent pressure and all the equivalent sources distributed on every source with known location and geometry information, and all the equivalent source strengths at each time step are solved by an iterative solving process; then, the corresponding equivalent source strengths of one interested source are used to calculate the pressure field generated by that source alone. Numerical simulation of two baffled circular pistons demonstrates that the proposed method can be effective in separating the non-stationary pressure generated by every source alone in both time and space domains. An experiment with two speakers in a semi-anechoic chamber further evidences the effectiveness of the proposed method.

  6. Internal split field generator

    DOEpatents

    Thundat,; George, Thomas [Knoxville, TN; Van Neste, Charles W [Kingston, TN; Vass, Arpad Alexander [Oak Ridge, TN

    2012-01-03

    A generator includes a coil of conductive material. A stationary magnetic field source applies a stationary magnetic field to the coil. An internal magnetic field source is disposed within a cavity of the coil to apply a moving magnetic field to the coil. The stationary magnetic field interacts with the moving magnetic field to generate an electrical energy in the coil.

  7. 40 CFR 98.192 - GHGs to report.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... emissions from lime kilns. (b) CO2 emissions from fuel combustion at lime kilns. (c) N2O and CH4 emissions... (General Stationary Fuel Combustion Sources). (d) CO2, N2O, and CH4 emissions from each stationary fuel... (General Stationary Fuel Combustion Sources). (e) CO2 collected and transferred off site under 40 CFR part...

  8. 40 CFR 98.192 - GHGs to report.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... emissions from lime kilns. (b) CO2 emissions from fuel combustion at lime kilns. (c) N2O and CH4 emissions... (General Stationary Fuel Combustion Sources). (d) CO2, N2O, and CH4 emissions from each stationary fuel... (General Stationary Fuel Combustion Sources). (e) CO2 collected and transferred off site under 40 CFR part...

  9. 40 CFR 98.192 - GHGs to report.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... emissions from lime kilns. (b) CO2 emissions from fuel combustion at lime kilns. (c) N2O and CH4 emissions... (General Stationary Fuel Combustion Sources). (d) CO2, N2O, and CH4 emissions from each stationary fuel... (General Stationary Fuel Combustion Sources). (e) CO2 collected and transferred off site under 40 CFR part...

  10. 40 CFR 98.192 - GHGs to report.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... emissions from lime kilns. (b) CO2 emissions from fuel combustion at lime kilns. (c) N2O and CH4 emissions... (General Stationary Fuel Combustion Sources). (d) CO2, N2O, and CH4 emissions from each stationary fuel... (General Stationary Fuel Combustion Sources). (e) CO2 collected and transferred off site under 40 CFR part...

  11. 40 CFR Table 3 to Subpart Zzzz of... - Subsequent Performance Tests

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .... Existing non-emergency, non-black start CI stationary RICE with a brake horsepower >500 that are not... 4SLB stationary RICE with a brake horsepower >500 located at major sources and new or reconstructed CI stationary RICE with a brake horsepower >500 located at major sources Reduce CO emissions and not using a...

  12. 40 CFR 70.2 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... program to control air pollution from outer continental shelf sources, under section 328 of the Act; (12... other functionally-equivalent opening. General permit means a part 70 permit that meets the requirements of § 70.6(d). Major source means any stationary source (or any group of stationary sources that are...

  13. 40 CFR 70.2 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... program to control air pollution from outer continental shelf sources, under section 328 of the Act; (12... other functionally-equivalent opening. General permit means a part 70 permit that meets the requirements of § 70.6(d). Major source means any stationary source (or any group of stationary sources that are...

  14. 40 CFR 70.2 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... program to control air pollution from outer continental shelf sources, under section 328 of the Act; (12... other functionally-equivalent opening. General permit means a part 70 permit that meets the requirements of § 70.6(d). Major source means any stationary source (or any group of stationary sources that are...

  15. REVIEW AND EVALUATION OF CURRENT METHODS AND USER NEEDS FOR OTHER STATIONARY COMBUSTION SOURCES

    EPA Science Inventory

    The report gives results of Phase 1 of an effort to develop improved methodologies for estimating area source emissions of air pollutants from stationary combustion sources. The report (1) evaluates Area and Mobile Source (AMS) subsystem methodologies; (2) compares AMS results w...

  16. 40 CFR 63.6585 - Am I subject to this subpart?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... if you own or operate a stationary RICE at a major or area source of HAP emissions, except if the stationary RICE is being tested at a stationary RICE test cell/stand. (a) A stationary RICE is any internal... not mobile. Stationary RICE differ from mobile RICE in that a stationary RICE is not a non-road engine...

  17. 40 CFR 63.6585 - Am I subject to this subpart?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... if you own or operate a stationary RICE at a major or area source of HAP emissions, except if the stationary RICE is being tested at a stationary RICE test cell/stand. (a) A stationary RICE is any internal... not mobile. Stationary RICE differ from mobile RICE in that a stationary RICE is not a non-road engine...

  18. REVISED EMISSIONS ESTIMATION METHODOLOGIES FOR INDUSTRIAL, RESIDENTIAL, AND ELECTRIC UTILITY STATIONARY COMBUSTION SOURCES

    EPA Science Inventory

    The report describes the development of improved and streamlined EPA emission estimation methods for stationary combustion area sources by the Joint Emissions Inventory Oversight Group (JEIOG) research program. These sources include categories traditionally labeled "other statio...

  19. EMISSION CHARACTERIZATION OF STATIONARY NOX SOURCES: VOLUME 1. RESULTS

    EPA Science Inventory

    The report gives results of an inventory of gaseous, liquid, and solid effluents from stationary NOx sources, projected to the year 2000, and ranks them according to their potential for environmental hazard. It classifies sources according to their pollution formation characteris...

  20. Status and Needs Research for On-line Monitoring of VOCs Emissions from Stationary Sources

    NASA Astrophysics Data System (ADS)

    Zhou, Gang; Wang, Qiang; Zhong, Qi; Zhao, Jinbao; Yang, Kai

    2018-01-01

    Based on atmospheric volatile organic compounds (VOCs) pollution control requirements during the twelfth-five year plan and the current status of monitoring and management at home and abroad, instrumental architecture and technical characteristics of continuous emission monitoring systems (CEMS) for VOCs emission from stationary sources are investigated and researched. Technological development needs of VOCs emission on-line monitoring techniques for stationary sources in china are proposed from the system sampling pretreatment technology and analytical measurement techniques.

  1. Correction for the detector-dead-time effect on the second-order correlation of stationary sub-Poissonian light in a two-detector configuration

    NASA Astrophysics Data System (ADS)

    Ann, Byoung-moo; Song, Younghoon; Kim, Junki; Yang, Daeho; An, Kyungwon

    2015-08-01

    Exact measurement of the second-order correlation function g(2 )(t ) of a light source is essential when investigating the photon statistics and the light generation process of the source. For a stationary single-mode light source, the Mandel Q factor is directly related to g(2 )(0 ) . For a large mean photon number in the mode, the deviation of g(2 )(0 ) from unity is so small that even a tiny error in measuring g(2 )(0 ) would result in an inaccurate Mandel Q . In this work, we address the detector-dead-time effect on g(2 )(0 ) of stationary sub-Poissonian light. It is then found that detector dead time can induce a serious error in g(2 )(0 ) and thus in Mandel Q in those cases even in a two-detector configuration. Utilizing the cavity-QED microlaser, a well-established sub-Poissonian light source, we measured g(2 )(0 ) with two different types of photodetectors with different dead times. We also introduced prolonged dead time by intentionally deleting the photodetection events following a preceding one within a specified time interval. We found that the observed Q of the cavity-QED microlaser was underestimated by 19% with respect to the dead-time-free Q when its mean photon number was about 600. We derived an analytic formula which well explains the behavior of the g(2 )(0 ) as a function of the dead time.

  2. 40 CFR 60.4239 - What are my compliance requirements if I am a manufacturer of stationary SI internal combustion...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... I am a manufacturer of stationary SI internal combustion engines >19 KW (25 HP) that use gasoline or... NEW STATIONARY SOURCES Standards of Performance for Stationary Spark Ignition Internal Combustion... manufacturer of stationary SI internal combustion engines >19 KW (25 HP) that use gasoline or a manufacturer of...

  3. 40 CFR 63.6590 - What parts of my plant does this subpart cover?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... existing, new, or reconstructed stationary RICE located at a major or area source of HAP emissions, excluding stationary RICE being tested at a stationary RICE test cell/stand. (1) Existing stationary RICE. (i) For stationary RICE with a site rating of more than 500 brake horsepower (HP) located at a major...

  4. 40 CFR 63.6590 - What parts of my plant does this subpart cover?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... existing, new, or reconstructed stationary RICE located at a major or area source of HAP emissions, excluding stationary RICE being tested at a stationary RICE test cell/stand. (1) Existing stationary RICE. (i) For stationary RICE with a site rating of more than 500 brake horsepower (HP) located at a major...

  5. Nitrogen saturation in the Rocky Mountains: Linking emissions, deposition, and ecosystem effects using stable isotopes of nitrogen compounds

    USGS Publications Warehouse

    Campbell, D.H.; Nanus, L.; Böhlke, J.K.; Harlin, K.; Collett, J.

    2007-01-01

    Elevated levels of atmospheric N deposition are affecting terrestrial and aquatic ecosystems at high elevations in Rocky Mountain National Park and adjacent areas of the Front Range of Colorado. Federal and state agencies are now working together to develop cost-effective means for reducing atmospheric N deposition. A discussion on N saturation covers the need for better understanding of N emission source areas and source types that contribute to N deposition in the Rocky Mountains Front Range of Colorado; reductions in NO emissions that resulted from Clean Air Act Amendments, which caused NO3 deposition to decrease between 1984 and 2003; factors contributing to N deposition, e.g., rapid population growth and energy development; origins of NO3, e.g., as NO emissions from fossil fuel combustion, including stationary sources (e.g. emission from coal combustion in electric generating units), and mobile sources (vehicle emissions); disperse stationary sources from energy resource development, e.g., natural gas production; and the importance of incorporating local source characterization and finer spatial and temporal sampling into future studies, which could provide additional insight into N deposition source attribution. This is an abstract of a paper presented at the 100th Annual Conference and Exhibition of the Air and Waste Management Association (Pittsburgh, PA 6/26-29/2007).

  6. 40 CFR 63.6612 - By what date must I conduct the initial performance tests or other initial compliance...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... stationary RICE with a site rating of less than or equal to 500 brake HP located at a major source of HAP emissions or an existing stationary RICE located at an area source of HAP emissions? 63.6612 Section 63.6612... other initial compliance demonstrations if I own or operate an existing stationary RICE with a site...

  7. 40 CFR 63.6612 - By what date must I conduct the initial performance tests or other initial compliance...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... stationary RICE with a site rating of less than or equal to 500 brake HP located at a major source of HAP emissions or an existing stationary RICE located at an area source of HAP emissions? 63.6612 Section 63.6612... other initial compliance demonstrations if I own or operate an existing stationary RICE with a site...

  8. 40 CFR 63.6085 - Am I subject to this subpart?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Standards for Hazardous Air Pollutants for Stationary Combustion Turbines What This Subpart Covers § 63.6085... combustion turbine located at a major source of HAP emissions. (a) Stationary combustion turbine means all... comprising any simple cycle stationary combustion turbine, any regenerative/recuperative cycle stationary...

  9. 40 CFR 63.6665 - What parts of the General Provisions apply to me?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... through 63.15 apply to you. If you own or operate a new or reconstructed stationary RICE with a site... reconstructed stationary RICE located at an area source of HAP emissions, or any of the following RICE with a... stationary RICE, an existing 4SLB stationary RICE, an existing stationary RICE that combusts landfill or...

  10. 40 CFR 63.6665 - What parts of the General Provisions apply to me?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... through 63.15 apply to you. If you own or operate a new or reconstructed stationary RICE with a site... reconstructed stationary RICE located at an area source of HAP emissions, or any of the following RICE with a... stationary RICE, an existing 4SLB stationary RICE, an existing stationary RICE that combusts landfill or...

  11. 40 CFR Table C-1 to Subpart C of... - Default CO2 Emission Factors and High Heat Values for Various Types of Fuel

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Heat Values for Various Types of Fuel C Table C-1 to Subpart C of Part 98 Protection of Environment... Stationary Fuel Combustion Sources Pt. 98, Subpt. C, Table C-1 Table C-1 to Subpart C of Part 98—Default CO2... input from MSW and/or tires; and (c) small batch incinerators that combust no more than 1,000 tons of...

  12. Improved Method for the Qualitative Analyses of Palm Oil Carotenes Using UPLC.

    PubMed

    Ng, Mei Han; Choo, Yuen May

    2016-04-01

    Palm oil is the richest source of natural carotenes, comprising 500-700 ppm in crude palm oil (CPO). Its concentration is found to be much higher in oil extracted from palm-pressed fiber, a by-product from the milling of oil palm fruits. There are 11 types of carotenes in palm oil, excluding the cis/trans isomers of some of the carotenes. Qualitative separation of these individual carotenes is particularly useful for the identification and confirmation of different types of oil as the carotenes profile is unique to each type of vegetable oil. Previous studies on HPLC separation of the individual palm carotenes reported a total analyses time of up to 100 min using C30 stationary phase. In this study, the separation was completed in <5 min. The qualitative separation was successfully carried out using a commonly used stationary phase, C18. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  13. 40 CFR 63.6603 - What emission limitations and operating limitations must I meet if I own or operate an existing...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... operating limitations must I meet if I own or operate an existing stationary RICE located at an area source... operating limitations must I meet if I own or operate an existing stationary RICE located at an area source... procedures in § 63.6620 and Table 4 to this subpart. (a) If you own or operate an existing stationary RICE...

  14. AIR POLLUTION CONTROL TECHNOLOGIES (CHAPTER 65)

    EPA Science Inventory

    The chapter discusses the use of technologies for reducing air pollution emissions from stationary sources, with emphasis on the control of combustion gen-erated air pollution. Major stationary sources include utility power boilers, industrial boilers and heaters, metal smelting ...

  15. Evaluation of lead levels in children living near a Los Angeles county battery recycling facility.

    PubMed Central

    Wohl, A R; Dominguez, A; Flessel, P

    1996-01-01

    This cross-sectional study examined the association between environmental lead measurements surrounding a Los Angeles County battery recycling facility and the blood lead levels of the children living nearby. Environmental lead measurements and blood lead levels of young children living in a community adjacent to a stationary lead source were compared to those living in a community without a stationary lead source. Predictors of blood lead level were identified. The blood lead levels of the children living near the secondary lead smelter were within the normal range (< 5 micrograms/dl). The absence of ground cover was associated with slightly increased blood lead levels; however, this increase was not of biological significance. Lead levels in surface soil near the stationary lead source were elevated compared to the control community; however, the soil affected community, which may be due in part to controls recently installed at the stationary lead source. PMID:8919770

  16. Nitrogen isotopes as indicators of NOx source contributions to atmospheric nitrate deposition across the midwestern and northeastern United States

    USGS Publications Warehouse

    Elliott, E.M.; Kendall, C.; Wankel, Scott D.; Burns, Douglas A.; Boyer, E.W.; Harlin, K.; Bain, D.J.; Butler, T.J.

    2007-01-01

    Global inputs of NOx are dominated by fossil fuel combustion from both stationary and vehicular sources and far exceed natural NOx sources. However, elucidating NOx sources to any given location remains a difficult challenge, despite the need for this information to develop sound regulatory and mitigation strategies. We present results from a regional-scale study of nitrogen isotopes (??15N) in wet nitrate deposition across 33 sites in the midwestern and northeastern U.S. We demonstrate that spatial variations in ??15N are strongly correlated with NOx emissions from surrounding stationary sources and additionally that ??15N is more strongly correlated with surrounding stationary source NOx emissions than pH, SO 42-, or NO3- concentrations. Although emission inventories indicate that vehicle emissions are the dominant NOx source in the eastern U.S., our results suggest that wet NO 3- deposition at sites in this study is strongly associated with NOx emissions from stationary sources. This suggests that large areas of the landscape potentially receive atmospheric NOy deposition inputs in excess of what one would infer from existing monitoring data alone. Moreover, we determined that spatial patterns in ??15N values are a robust indicator of stationary NOx contributions to wet NO3- deposition and hence a valuable complement to existing tools for assessing relationships between NO 3- deposition, regional emission inventories, and for evaluating progress toward NOx reduction goals. ?? 2007 American Chemical Society.

  17. NEW TECHNOLOGY FOR THE CONTROL OF AEROSOLS FROM STATIONARY SOURCES

    EPA Science Inventory

    The paper discusses an EPA program to develop new technologies for controlling particulate matter from stationary sources, including both electrostatically augmented fabric filtration (ESFF) and electrostatic precipitators (ESPs). The first generation ESFF system, using an electr...

  18. 40 CFR 63.6600 - What emission limitations and operating limitations must I meet if I own or operate a stationary...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... operating limitations must I meet if I own or operate a stationary RICE with a site rating of more than 500... RICE with a site rating of more than 500 brake HP located at a major source of HAP emissions... 4SRB stationary RICE with a site rating of more than 500 brake HP located at a major source of HAP...

  19. 40 CFR 63.6600 - What emission limitations and operating limitations must I meet if I own or operate a stationary...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... operating limitations must I meet if I own or operate a stationary RICE with a site rating of more than 500... RICE with a site rating of more than 500 brake HP located at a major source of HAP emissions... 4SRB stationary RICE with a site rating of more than 500 brake HP located at a major source of HAP...

  20. 40 CFR Table 1b to Subpart Zzzz of... - Operating Limitations for Existing, New, and Reconstructed SI 4SRB Stationary RICE >500 HP...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., New, and Reconstructed SI 4SRB Stationary RICE >500 HP Located at a Major Source of HAP Emissions 1b... Limitations for Existing, New, and Reconstructed SI 4SRB Stationary RICE >500 HP Located at a Major Source of... 15 percent O2 and using NSCR; a. maintain your catalyst so that the pressure drop across the catalyst...

  1. 40 CFR Table 1b to Subpart Zzzz of... - Operating Limitations for Existing, New, and Reconstructed SI 4SRB Stationary RICE >500 HP...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., New, and Reconstructed SI 4SRB Stationary RICE >500 HP Located at a Major Source of HAP Emissions 1b... Limitations for Existing, New, and Reconstructed SI 4SRB Stationary RICE >500 HP Located at a Major Source of... 15 percent O2 and using NSCR; a. maintain your catalyst so that the pressure drop across the catalyst...

  2. 77 FR 282 - Proposed Settlement Agreement

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-04

    ... revised the National Emission Standards for Hazardous Air Pollutants for Reciprocating Internal Combustion... the stationary internal combustion engine new source performance standards (ICE NSPS) to allow owners and operators of emergency stationary internal combustion engines to operate emergency stationary...

  3. 40 CFR Table C-1 to Subpart C of... - Default CO2 Emission Factors and High Heat Values for Various Types of Fuel

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Heat Values for Various Types of Fuel C Table C-1 to Subpart C of Part 98 Protection of Environment... Stationary Fuel Combustion Sources Pt. 98, Subpt. C, Table C-1 Table C-1 to Subpart C of Part 98—Default CO2... exception of ethylene. 2 Ethylene HHV determined at 41 °F (5 °C) and saturation pressure. 3 Use of this...

  4. 40 CFR Appendix D to Part 52 - Determination of Sulfur Dioxide Emissions From Stationary Sources by Continuous Monitors

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Emissions From Stationary Sources by Continuous Monitors D Appendix D to Part 52 Protection of Environment... equipment required for the continuous determination of SO2 gas concentration in a given source effluent. 1... Drift. The change in measurement system output over a stated period of time of normal continuous...

  5. Development of Methods for Sampling and Analysis of Particulate and Gaseous Fluorides from Stationary Sources.

    ERIC Educational Resources Information Center

    Peters, E. T.; And Others

    A study was conducted which has resulted in the development of tentative sampling and analysis of fluorides emitted from various stationary sources. The study was directed toward developing and understanding the kinds of species which are present in each source emission. The report presents the following information: review of the various unit…

  6. Iowa SIP: Chapter 33 - Special Regulations and Construction Permit Requirements for Major Stationary Sources - Prevention of Significant Deterioration (PSD) of Air Quality

    EPA Pesticide Factsheets

    EPA Approved Iowa Regulations - 40 CFR 52.820(c) Chapter 33 - Special Regulations and Construction Permit Requirements for Major Stationary Sources - Prevention of Significant Deterioration (PSD) of Air Quality

  7. 40 CFR Table 2a to Subpart Zzzz of... - Emission Limitations for New and Reconstructed 2SLB and Compression Ignition Stationary RICE >500...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Reconstructed 2SLB and Compression Ignition Stationary RICE >500 HP and New and Reconstructed 4SLB Stationary RICE â¥250 HP Located at a Major Source of HAP Emissions 2a Table 2a to Subpart ZZZZ of Part 63... 2SLB and Compression Ignition Stationary RICE >500 HP and New and Reconstructed 4SLB Stationary RICE...

  8. 40 CFR Table 2a to Subpart Zzzz of... - Emission Limitations for New and Reconstructed 2SLB and Compression Ignition Stationary RICE >500...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Reconstructed 2SLB and Compression Ignition Stationary RICE >500 HP and New and Reconstructed 4SLB Stationary RICE â¥250 HP Located at a Major Source of HAP Emissions 2a Table 2a to Subpart ZZZZ of Part 63... 2SLB and Compression Ignition Stationary RICE >500 HP and New and Reconstructed 4SLB Stationary RICE...

  9. 40 CFR 52.1110 - Small business stationary source technical and environmental compliance assistance program.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... technical and environmental compliance assistance program. 52.1110 Section 52.1110 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Maryland § 52.1110 Small business stationary source technical and environmental...

  10. APPLYING OPEN-PATH OPTICAL SPECTROSCOPY TO HEAVY-DUTY DIESEL EMISSIONS

    EPA Science Inventory

    Non-dispersive infrared absorption has been used to measure gaseous emissions for both stationary and mobile sources. Fourier transform infrared spectroscopy has been used for stationary sources as both extractive and open-path methods. We have applied the open-path method for bo...

  11. HP-25 PROGRAMMABLE POCKET CALCULATOR APPLIED TO AIR POLLUTION MEASUREMENT STUDIES: STATIONARY SOURCES

    EPA Science Inventory

    The report should be useful to persons concerned with Air Pollution Measurement Studies of Stationary Industrial Sources. It gives detailed descriptions of 22 separate programs, written specifically for the Hewlett Packard Model HP-25 manually programmable pocket calculator. Each...

  12. HP-65 PROGRAMMABLE POCKET CALCULATOR APPLIED TO AIR POLLUTION MEASUREMENT STUDIES: STATIONARY SOURCES

    EPA Science Inventory

    The handbook is intended for persons concerned with air pollution measurement studies of stationary industrial sources. It gives detailed descriptions of 22 different programs written specifically for the Hewlett Packard Model HP-65 card-programmable pocket calculator. For each p...

  13. 77 FR 40879 - Agency Information Collection Activities; Submission to OMB for Review and Approval; Comment...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-11

    ... Compression Ignition Internal Combustion Engines (Renewal) AGENCY: Environmental Protection Agency (EPA....regulations.gov . Title: NSPS for Stationary Source Compression Ignition Internal Combustion Engines (Renewal... Performance Standards (NSPS) for Stationary Source Compression Ignition Internal Combustion Engines (40 CFR...

  14. Procedure 5 Quality Assurance Requirements For Vapor Phase Mercury Continuous Emissions Monitoring Systems And Sorbent Trap Monitoring Systems Used For Compliance Determination At Stationary Sources

    EPA Pesticide Factsheets

    Promulgated quality assurance Procedure 5 Quality Assurance Requirements For Vapor Phase Mercury Continuous Emissions Monitoring Systems And Sorbent Trap Monitoring Systems Used For Compliance Determination At Stationary Sources

  15. A complete analytical solution of the Fokker-Planck and balance equations for nucleation and growth of crystals

    NASA Astrophysics Data System (ADS)

    Makoveeva, Eugenya V.; Alexandrov, Dmitri V.

    2018-01-01

    This article is concerned with a new analytical description of nucleation and growth of crystals in a metastable mushy layer (supercooled liquid or supersaturated solution) at the intermediate stage of phase transition. The model under consideration consisting of the non-stationary integro-differential system of governing equations for the distribution function and metastability level is analytically solved by means of the saddle-point technique for the Laplace-type integral in the case of arbitrary nucleation kinetics and time-dependent heat or mass sources in the balance equation. We demonstrate that the time-dependent distribution function approaches the stationary profile in course of time. This article is part of the theme issue `From atomistic interfaces to dendritic patterns'.

  16. 40 CFR 98.193 - Calculating GHG emissions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Stationary Fuel Combustion Sources). (2) Calculate and report process and combustion CO2 emissions separately... Stationary Fuel Combustion Sources) the combustion CO2 emissions from each lime kiln according to the... must calculate and report the annual process CO2 emissions from all lime kilns combined using the...

  17. 40 CFR 98.193 - Calculating GHG emissions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Stationary Fuel Combustion Sources). (2) Calculate and report process and combustion CO2 emissions separately... Stationary Fuel Combustion Sources) the combustion CO2 emissions from each lime kiln according to the... must calculate and report the annual process CO2 emissions from all lime kilns combined using the...

  18. Montana SIP: Table c, (viii) Administrative Rules of Montana, Subchapter 10, Preconstruction Permit Requirements for Major Stationary Sources or Major Modifications Locating Within Attainment or Unclassified Areas

    EPA Pesticide Factsheets

    Montana SIP: Table c, (viii) Administrative Rules of Montana, Subchapter 10, Preconstruction Permit Requirements for Major Stationary Sources or Major Modifications Locating Within Attainment or Unclassified Areas

  19. Sewage Treatment Plants: Standards of Performance for New Stationary Sources 1989 Final Rule (54 FR 6660)

    EPA Pesticide Factsheets

    This document includes a copy of the Federal Register publication of the February 14, 1989 Final Rule for the Standards of Performance of New Stationary Sources for Sewage Treatment Plants. This document is provided courtesy of HeinOnline.

  20. 40 CFR 68.160 - Registration.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... stationary source Dun and Bradstreet number; (3) Name and Dun and Bradstreet number of the corporate parent company; (4) The name, telephone number, and mailing address of the owner or operator; (5) The name and...) Stationary source name, street, city, county, state, zip code, latitude and longitude, method for obtaining...

  1. A DECAMETER STATIONARY TYPE IV BURST IN IMAGING OBSERVATIONS ON 2014 SEPTEMBER 6

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koval, Artem; Chen, Yao; Feng, Shiwei

    2016-08-01

    First-of-its-kind radio imaging of a decameter solar stationary type IV radio burst has been presented in this paper. On 2014 September 6 the observations of type IV burst radio emission were carried out with the two-dimensional heliograph based on the Ukrainian T-shaped radio telescope (UTR-2), together with other telescope arrays. Starting at ∼09:55 UT and for ∼3 hr, the radio emission was kept within the observational session of UTR-2. The interesting observation covered the full evolution of this burst, “from birth to death.” During the event lifetime, two C-class solar X-ray flares with peak times 11:29 UT and 12:24 UTmore » took place. The time profile of this burst in radio has a double-humped shape that can be explained by injection of energetic electrons, accelerated by the two flares, into the burst source. According to the heliographic observations, we suggest that the burst source was confined within a high coronal loop, which was part of a relatively slow coronal mass ejection. The latter has been developed for several hours before the onset of the event. Through analysis of about 1.5 × 10{sup 6} heliograms (3700 temporal frames with 4096 images in each frame that correspond to the number of frequency channels), the radio burst source imaging shows a fascinating dynamical evolution. Both space-based ( GOES , SDO , SOHO , STEREO ) data and various ground-based instrumentation (ORFEES, NDA, RSTO, NRH) records have been used for this study.« less

  2. Framework for Assessing Biogenic CO2 Emissions from ...

    EPA Pesticide Factsheets

    This revision of the 2011 report, Accounting Framework for Biogenic CO2 Emissions from Stationary Sources, evaluates biogenic CO2 emissions from stationary sources, including a detailed study of the scientific and technical issues associated with assessing biogenic carbon dioxide emissions from stationary sources. EPA developed the revised report, Framework for Assessing Biogenic CO2 Emissions from Stationary Sources, to present a methodological framework for assessing the extent to which the production, processing, and use of biogenic material at stationary sources for energy production results in a net atmospheric contribution of biogenic CO2 emissions. Biogenic carbon dioxide emissions are defined as CO2 emissions related to the natural carbon cycle, as well as those resulting from the production, harvest, combustion, digestion, decomposition, and processing of biologically-based materials. The EPA is continuing to refine its technical assessment of biogenic CO2 emissions through another round of targeted peer review of the revised study with the EPA Science Advisory Board (SAB). This study was submitted to the SAB's Biogenic Carbon Emissions Panel in February 2015. http://yosemite.epa.gov/sab/sabproduct.nsf/0/3235dac747c16fe985257da90053f252!OpenDocument&TableRow=2.2#2 The revised report will inform efforts by policymakers, academics, and other stakeholders to evaluate the technical aspects related to assessments of biogenic feedstocks used for energy at s

  3. Contributions of mobile, stationary and biogenic sources to air pollution in the Amazon rainforest: a numerical study with the WRF-Chem model

    NASA Astrophysics Data System (ADS)

    Abou Rafee, Sameh A.; Martins, Leila D.; Kawashima, Ana B.; Almeida, Daniela S.; Morais, Marcos V. B.; Souza, Rita V. A.; Oliveira, Maria B. L.; Souza, Rodrigo A. F.; Medeiros, Adan S. S.; Urbina, Viviana; Freitas, Edmilson D.; Martin, Scot T.; Martins, Jorge A.

    2017-06-01

    This paper evaluates the contributions of the emissions from mobile, stationary and biogenic sources on air pollution in the Amazon rainforest by using the Weather Research and Forecasting with Chemistry (WRF-Chem) model. The analyzed air pollutants were CO, NOx, SO2, O3, PM2. 5, PM10 and volatile organic compounds (VOCs). Five scenarios were defined in order to evaluate the emissions by biogenic, mobile and stationary sources, as well as a future scenario to assess the potential air quality impact of doubled anthropogenic emissions. The stationary sources explain the highest concentrations for all air pollutants evaluated, except for CO, for which the mobile sources are predominant. The anthropogenic sources considered resulted an increasing in the spatial peak-temporal average concentrations of pollutants in 3 to 2780 times in relation to those with only biogenic sources. The future scenario showed an increase in the range of 3 to 62 % in average concentrations and 45 to 109 % in peak concentrations depending on the pollutant. In addition, the spatial distributions of the scenarios has shown that the air pollution plume from the city of Manaus is predominantly transported west and southwest, and it can reach hundreds of kilometers in length.

  4. 78 FR 54606 - National Emission Standards for Hazardous Air Pollutants for Reciprocating Internal Combustion...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-05

    ... Combustion Engines; New Source Performance Standards for Stationary Internal Combustion Engines AGENCY... hazardous air pollutants for stationary reciprocating internal combustion engines and the standards of performance for stationary internal combustion engines. Subsequently, the EPA received three petitions for...

  5. 40 CFR 70.2 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... section 183(f) of the Act; (11) Any standard or other requirement of the program to control air pollution... emissions which could not reasonably pass through a stack, chimney, vent, or other functionally-equivalent... means any stationary source (or any group of stationary sources that are located on one or more...

  6. 77 FR 5700 - Approval and Promulgation of Implementation Plans; New Hampshire: Prevention of Significant...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-06

    ... appropriate emission thresholds for determining which new stationary sources and modification projects become... affects major stationary sources in New Hampshire that have GHG emissions above the thresholds established... higher thresholds in the Tailoring Rule, EPA published a final rule on December 30, 2010, narrowing its...

  7. 77 FR 60907 - Approval and Promulgation of Implementation Plans; Vermont: Prevention of Significant...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-05

    ...) program to establish appropriate emission thresholds for determining which new stationary sources and.... This action affects major stationary sources in Vermont that have GHG emissions above the thresholds... of GHG, and do not limit PSD applicability to GHGs to the higher thresholds in the Tailoring Rule...

  8. 76 FR 61100 - Notification of a Public Meeting of the Science Advisory Board Biogenic Carbon Emissions Panel

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-03

    ... demonstrated expertise in forestry, agriculture, measurement and carbon accounting methodologies, land use... draft Accounting Framework for Biogenic CO 2 Emissions from Stationary Sources (September 2011). DATES... review EPA's draft Accounting Framework for Biogenic CO 2 Emissions from Stationary Sources (September...

  9. 76 FR 72700 - Agency Information Collection Activities; Proposed Collections; Comment Request; Prevention of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-25

    ... review programs for new or modified stationary sources of air pollution. In addition, the provisions of... the emissions from the construction and modification of any stationary source of air pollution to.... Partially counteracting these increases, the Flexible Air Permitting Rule had the effect of reducing the...

  10. GUIDELINES FOR MERCURY MEASUREMENTS FROM STATIONARY SOURCES: QUALITY ASSURANCE HANDBOOK, SECTION 3.19

    EPA Science Inventory

    Method 101A (M101A) is similar to Method 101 for the determination of mercury (Hg) from stationary sources. n M101A, however, acidic potassium permanganate solution is used for sample collection instead of acidic iodine monochloride solution. his method applies to the determinati...

  11. Sewage Treatment Plants: Standards of Performance for New Stationary Sources 1977 Final Rule (42 FR 58520)

    EPA Pesticide Factsheets

    This document includes a copy of the Federal Register publication of the November 10, 1977 Final Rule for the Standards of Performance of New Stationary Sources for 40 CFR 60 Subparts O. This document is provided curtesy of HeinOnline.

  12. 40 CFR 52.1037 - Original identification of plan section.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... operation of new and modified major stationary sources of pollution in attainment areas. (11) Attainment... review of construction and operation of new and modified major stationary sources of pollution in non... involvement in federally funded air pollution control activities was submitted on May 28, 1980. (13) Revisions...

  13. 40 CFR 52.1037 - Original identification of plan section.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... operation of new and modified major stationary sources of pollution in attainment areas. (11) Attainment... review of construction and operation of new and modified major stationary sources of pollution in non... involvement in federally funded air pollution control activities was submitted on May 28, 1980. (13) Revisions...

  14. 40 CFR Table 1b to Subpart Zzzz of... - Operating Limitations for Existing, New, and Reconstructed Spark Ignition, 4SRB Stationary RICE...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., New, and Reconstructed Spark Ignition, 4SRB Stationary RICE >500 HP Located at a Major Source of HAP... Limitations for Existing, New, and Reconstructed Spark Ignition, 4SRB Stationary RICE >500 HP Located at a... following operating emission limitations for existing, new and reconstructed 4SRB stationary RICE >500 HP...

  15. 40 CFR Table 1a to Subpart Zzzz of... - Emission Limitations for Existing, New, and Reconstructed Spark Ignition, 4SRB Stationary RICE...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., and Reconstructed Spark Ignition, 4SRB Stationary RICE >500 HP Located at a Major Source of HAP... Limitations for Existing, New, and Reconstructed Spark Ignition, 4SRB Stationary RICE >500 HP Located at a... emission limitations for existing, new and reconstructed 4SRB stationary RICE at 100 percent load plus or...

  16. 40 CFR 60.4206 - How long must I meet the emission standards if I am an owner or operator of a stationary CI...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... emission standards as required in §§ 60.4204 and 60.4205 according to the manufacturer's written... standards if I am an owner or operator of a stationary CI internal combustion engine? 60.4206 Section 60...) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Stationary Compression...

  17. 40 CFR 63.6085 - Am I subject to this subpart?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) National Emission Standards for Hazardous Air Pollutants for Stationary Combustion Turbines What This... operate a stationary combustion turbine located at a major source of HAP emissions. (a) Stationary combustion turbine means all equipment, including but not limited to the turbine, the fuel, air, lubrication...

  18. 40 CFR 63.6085 - Am I subject to this subpart?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) National Emission Standards for Hazardous Air Pollutants for Stationary Combustion Turbines What This... operate a stationary combustion turbine located at a major source of HAP emissions. (a) Stationary combustion turbine means all equipment, including but not limited to the turbine, the fuel, air, lubrication...

  19. 40 CFR 63.6085 - Am I subject to this subpart?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) National Emission Standards for Hazardous Air Pollutants for Stationary Combustion Turbines What This... operate a stationary combustion turbine located at a major source of HAP emissions. (a) Stationary combustion turbine means all equipment, including but not limited to the turbine, the fuel, air, lubrication...

  20. Evaluating measurements of carbon dioxide emissions using a precision source--A natural gas burner.

    PubMed

    Bryant, Rodney; Bundy, Matthew; Zong, Ruowen

    2015-07-01

    A natural gas burner has been used as a precise and accurate source for generating large quantities of carbon dioxide (CO2) to evaluate emissions measurements at near-industrial scale. Two methods for determining carbon dioxide emissions from stationary sources are considered here: predicting emissions based on fuel consumption measurements-predicted emissions measurements, and direct measurement of emissions quantities in the flue gas-direct emissions measurements. Uncertainty for the predicted emissions measurement was estimated at less than 1%. Uncertainty estimates for the direct emissions measurement of carbon dioxide were on the order of ±4%. The relative difference between the direct emissions measurements and the predicted emissions measurements was within the range of the measurement uncertainty, therefore demonstrating good agreement. The study demonstrates how independent methods are used to validate source emissions measurements, while also demonstrating how a fire research facility can be used as a precision test-bed to evaluate and improve carbon dioxide emissions measurements from stationary sources. Fossil-fuel-consuming stationary sources such as electric power plants and industrial facilities account for more than half of the CO2 emissions in the United States. Therefore, accurate emissions measurements from these sources are critical for evaluating efforts to reduce greenhouse gas emissions. This study demonstrates how a surrogate for a stationary source, a fire research facility, can be used to evaluate the accuracy of measurements of CO2 emissions.

  1. Effect of specific amino acids on growth and aflatoxin production by Aspergillus parasiticus and Aspergillus flavus in defined media.

    PubMed Central

    Payne, G A; Hagler, W M

    1983-01-01

    Four amino acids were used as sole nitrogen sources or as supplements to ammonium sulfate, and casein and ammonium sulfate were used as sole nitrogen sources to examine their effects on aflatoxin production by Aspergillus parasiticus NRRL 2999 and Aspergillus flavus 3357 grown on synthetic liquid media. In general, when proline, asparagine, casein, and ammonium sulfate were used as sole nitrogen sources, they supported more growth and toxin production than tryptophan or methionine. However, proline stimulated more toxin production per gram of mycelium in stationary cultures than the other nitrogen sources, including the amino acid asparagine, which is generally recognized as supporting good aflatoxin production. The exact responses to individual nitrogen sources were influenced by the species of fungus and whether cultures were stationary or shaken. In shake cultures, but not in stationary cultures, increased growth was generally associated with increased toxin production. PMID:6416168

  2. Standards of Performance for New Stationary Sources (40 CFR 60 Subparts A, D, E, F, G and H): 1971 Final Rules (36 FR 24876)

    EPA Pesticide Factsheets

    This document includes a copy of the Federal Register publication of the December 23, 1971 Final Rule for the Standards of Performance of New Stationary Sources for 40 CFR 60 subparts Subparts A, D, E, F, G, and H.

  3. 40 CFR 52.730 - Compliance schedules.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Pollution Control Regulations Rule 203(d)(4), 203(d)(6)(B)(ii)(bb), 203(g)(1)(B), 203(g)(2), 203(g)(3), 203... operator of any stationary source subject to Illinois Air Pollution Control Regulation Rule 203(d)(4) shall... or operator of any stationary source subject to Illinois Air Pollution Control Regulation Rule 203(d...

  4. 40 CFR 52.730 - Compliance schedules.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Pollution Control Regulations Rule 203(d)(4), 203(d)(6)(B)(ii)(bb), 203(g)(1)(B), 203(g)(2), 203(g)(3), 203... operator of any stationary source subject to Illinois Air Pollution Control Regulation Rule 203(d)(4) shall... or operator of any stationary source subject to Illinois Air Pollution Control Regulation Rule 203(d...

  5. 40 CFR 52.730 - Compliance schedules.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Pollution Control Regulations Rule 203(d)(4), 203(d)(6)(B)(ii)(bb), 203(g)(1)(B), 203(g)(2), 203(g)(3), 203... operator of any stationary source subject to Illinois Air Pollution Control Regulation Rule 203(d)(4) shall... or operator of any stationary source subject to Illinois Air Pollution Control Regulation Rule 203(d...

  6. 76 FR 76713 - Agency Information Collection Activities; Proposed Collections; Comment Request; Prevention of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-08

    ... review programs for new or modified stationary sources of air pollution. In addition, the provisions of... the emissions from the construction and modification of any stationary source of air pollution to... Flexible Air Permitting Rule also slightly reduced the burden per minor NSR permit. As a result of all...

  7. Calendar Year 2016 Stationary Source Emissions Inventory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Evelo, Stacie

    2017-01-01

    The City of Albuquerque (COA) Environmental Health Department Air Quality Program has issued stationary source permits and registrations the Department of Energy/Sandia Field Office for operations at the Sandia National Laboratories/New Mexico. This emission inventory report meets the annual reporting compliance requirements for calendar year (CY) 2016 as required by the COA.

  8. Standards of Performance for New Stationary Sources; Petroleum Dry Cleaners: 1985 Response to Petition for Reconsideration & Final Amendments to the Rule (50 FR 49022)

    EPA Pesticide Factsheets

    This document is a copy of the Federal Register publication of the November 27, 1985 Response to Petition for Reconsideration and Final Amendments to the Rule for the Standards of Performance for New Stationary Sources; Petroleum Dry Cleaners.

  9. 77 FR 32493 - Approval of Air Quality Implementation Plans; California; San Joaquin Valley Unified Air...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-01

    ... permit program for pre- construction review of certain new and modified major stationary sources in... program as required by section 165 of the CAA for certain new and modified major stationary sources... the CAA requires states to adopt a pre-construction permitting program for certain new and modified...

  10. 40 CFR Table 7 to Subpart Zzzz of... - Requirements for Reports

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... submit a . . . The report must contain . . . You must submit the report . . . 1. Existing non-emergency, non-black start stationary RICE 100≤HP≤500 located at a major source of HAP; existing non-emergency, non-black start stationary CI RICE >500 HP located at a major source of HAP; existing non-emergency...

  11. 40 CFR Table 7 to Subpart Zzzz of... - Requirements for Reports

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... submit a . . . The report must contain . . . You must submit the report . . . 1. Existing non-emergency, non-black start stationary RICE 100≤HP≤500 located at a major source of HAP; existing non-emergency, non-black start stationary CI RICE >500 HP located at a major source of HAP; existing non-emergency...

  12. The acoustic monopole in motion

    NASA Technical Reports Server (NTRS)

    Norum, T. D.; Liu, C. H.

    1976-01-01

    The results of an experiment are presented in which a small monochromatic source which behaves like an acoustic monopole when stationary is moved at a constant speed over an asphalt surface past stationary microphones. An analysis of the monopole moving above a finite impedance reflecting plane is given. The theoretical and experimental results are compared for different ground to observer heights, source frequencies, and source velocities. A computation of the effects of source acceleration on the noise radiated by the monopole is also presented.

  13. 40 CFR Table 7 to Subpart Zzzz of... - Requirements for Reports

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... submit a ... The report must contain ... You must submit the report ... 1. Existing non-emergency, non-black start stationary RICE 100 ≤ HP ≤ 500 located at a major source of HAP; existing non-emergency, non-black start stationary CI RICE > 500 HP located at a major source of HAP; existing non-emergency 4SRB...

  14. 40 CFR Table 7 to Subpart Zzzz of... - Requirements for Reports

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... submit a ... The report must contain ... You must submit the report ... 1. Existing non-emergency, non-black start stationary RICE 100 ≤ HP ≤ 500 located at a major source of HAP; existing non-emergency, non-black start stationary CI RICE > 500 HP located at a major source of HAP; existing non-emergency 4SRB...

  15. Non-stationary (13)C-metabolic flux ratio analysis.

    PubMed

    Hörl, Manuel; Schnidder, Julian; Sauer, Uwe; Zamboni, Nicola

    2013-12-01

    (13)C-metabolic flux analysis ((13)C-MFA) has become a key method for metabolic engineering and systems biology. In the most common methodology, fluxes are calculated by global isotopomer balancing and iterative fitting to stationary (13)C-labeling data. This approach requires a closed carbon balance, long-lasting metabolic steady state, and the detection of (13)C-patterns in a large number of metabolites. These restrictions mostly reduced the application of (13)C-MFA to the central carbon metabolism of well-studied model organisms grown in minimal media with a single carbon source. Here we introduce non-stationary (13)C-metabolic flux ratio analysis as a novel method for (13)C-MFA to allow estimating local, relative fluxes from ultra-short (13)C-labeling experiments and without the need for global isotopomer balancing. The approach relies on the acquisition of non-stationary (13)C-labeling data exclusively for metabolites in the proximity of a node of converging fluxes and a local parameter estimation with a system of ordinary differential equations. We developed a generalized workflow that takes into account reaction types and the availability of mass spectrometric data on molecular ions or fragments for data processing, modeling, parameter and error estimation. We demonstrated the approach by analyzing three key nodes of converging fluxes in central metabolism of Bacillus subtilis. We obtained flux estimates that are in agreement with published results obtained from steady state experiments, but reduced the duration of the necessary (13)C-labeling experiment to less than a minute. These results show that our strategy enables to formally estimate relative pathway fluxes on extremely short time scale, neglecting cellular carbon balancing. Hence this approach paves the road to targeted (13)C-MFA in dynamic systems with multiple carbon sources and towards rich media. © 2013 Wiley Periodicals, Inc.

  16. 77 FR 52553 - Standards of Performance for Stationary Gas Turbines; Standards of Performance for Stationary...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-29

    ...The EPA is proposing to amend the new source performance standards (NSPS) for stationary gas turbines and stationary combustion turbines. These amendments are primarily in response to issues raised by the regulated community. On July 6, 2006, the EPA promulgated amendments to the new source performance standards for stationary combustion turbines. On September 5, 2006, the Utility Air Regulatory Group filed a petition for reconsideration of certain aspects of the promulgated standards. The EPA is proposing to amend specific provisions in the NSPS to resolve issues and questions raised by the petition for reconsideration, and to address other technical and editorial issues. In addition, this proposed rule would amend the location and wording of existing paragraphs for clarity. The proposed amendments would increase the environmental benefits of the existing requirements because the emission standards would apply at all times. The proposed amendments would also promote efficiency by recognizing the environmental benefit of combined heat and power and the beneficial use of low energy content gases.

  17. 76 FR 59512 - Approval and Promulgation of Air Quality Implementation Plans; Indiana; Redesignation of the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-27

    ... inventories for primary PM 2.5 ,\\1\\ NO X , and Sulfur Dioxide (SO 2 ),\\2\\ documented in Indiana's May 31, 2011... quantification of allowable emissions for major new and modified stationary sources in an area, and section 172(c)(5) requires source permits for the construction and operation of new and modified major stationary...

  18. Air Quality and Stationary Source Emission Control; Committee on Public Works, Senate, Ninety-Fourth Congress, First Session. [Committee Print.

    ERIC Educational Resources Information Center

    National Academy of Sciences - National Research Council, Washington, DC.

    This report reviews the problems of sulfur oxide emissions and nitrogen oxide emissions from stationary sources. The first part of the report discusses the adverse consequences to health from combustion of sulfur-containing fossil fuels. The health problem is discussed by relating sulfur oxide levels and respirable particulate matter with…

  19. Design of a new separable rotary transformer

    NASA Astrophysics Data System (ADS)

    Gong, X. F.; Zhang, L.; Feng, E. J.

    2017-09-01

    A new-type separable rotary transformer which can be used in rotary steerable drilling is designed to deliver power efficiently from a stationary primary source to a rotary secondary load over a relatively large air gap via magnetic coupling. In this paper, E-type magnetic cores are reasonably distributed so that rotation of the rotary secondary has the least influence on reluctance of magnetic coupling. The influence of different winding layouts and connection modes on self-inductance and coupling coefficient is studied. By analysing the influence of the different geometrical shapes of cores on magnetic path, a design principle is proposed.

  20. Supplement B to compilation of air pollutant emission factors, volume 1. Stationary point and area sources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    This document contains emission factors and process information for more than 200 air pollution source categories. This Supplement to AP-42 addresses pollutant-generating activity from Bituminous And Subbituminous Coal Combustion, Anthracite Coal Combustion, Fuel Oil Combustion, Natural Gas Combustion, Liquefied Petroleum Gas Combustion, Wood Waste Combustion In Boilers, Lignite Combustion, Bagasse Combustion In Sugar Mills, Residential Fireplaces, Residential Wood Stoves, Waste Oil Combustion, Stationary Gas Turbines For Electricity Generation, Heavy-duty Natural Gas-fired Pipeline Compressor Engines And Turbines, Gasoline and Diesel Industrial Engines, Large Stationary Diesel And All Stationary Dual-fuel Engines, Adipic Acid, Cotton Ginning, Alfafalfa Dehydrating, Malt Beverages, Ceramic Products Manufacturing,more » Electroplating, Wildfires And Prescribed Burning, Emissions From Soils-Greenhouse Gases, Termites-Greenhouse Gases, and Lightning Emissions-Greenhouse Gases.« less

  1. 40 CFR Table 5 to Subpart IIIi of... - Labeling and Recordkeeping Requirements for New Stationary Emergency Engines

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Labeling and Recordkeeping Requirements for New Stationary Emergency Engines 5 Table 5 to Subpart IIII of Part 60 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance fo...

  2. 40 CFR Table 5 to Subpart IIIi of... - Labeling and Recordkeeping Requirements for New Stationary Emergency Engines

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Labeling and Recordkeeping Requirements for New Stationary Emergency Engines 5 Table 5 to Subpart IIII of Part 60 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance fo...

  3. 40 CFR Table 5 to Subpart IIIi of... - Labeling and Recordkeeping Requirements for New Stationary Emergency Engines

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Labeling and Recordkeeping Requirements for New Stationary Emergency Engines 5 Table 5 to Subpart IIII of Part 60 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance fo...

  4. 40 CFR Table 5 to Subpart IIIi of... - Labeling and Recordkeeping Requirements for New Stationary Emergency Engines

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Labeling and Recordkeeping Requirements for New Stationary Emergency Engines 5 Table 5 to Subpart IIII of Part 60 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance fo...

  5. 40 CFR Table 5 to Subpart IIIi of... - Labeling and Recordkeeping Requirements for New Stationary Emergency Engines

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Labeling and Recordkeeping Requirements for New Stationary Emergency Engines 5 Table 5 to Subpart IIII of Part 60 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance fo...

  6. 40 CFR 60.4247 - What parts of the mobile source provisions apply to me if I am a manufacturer of stationary SI...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false What parts of the mobile source provisions apply to me if I am a manufacturer of stationary SI internal combustion engines or a manufacturer of equipment containing such engines? 60.4247 Section 60.4247 Protection of Environment ENVIRONMENTAL...

  7. 40 CFR 98.32 - GHGs to report.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... GREENHOUSE GAS REPORTING General Stationary Fuel Combustion Sources § 98.32 GHGs to report. You must report CO2, CH4, and N2O mass emissions from each stationary fuel combustion unit, except as otherwise...

  8. 40 CFR 98.32 - GHGs to report.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... GREENHOUSE GAS REPORTING General Stationary Fuel Combustion Sources § 98.32 GHGs to report. You must report CO2, CH4, and N2O mass emissions from each stationary fuel combustion unit, except as otherwise...

  9. 40 CFR 98.32 - GHGs to report.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... GREENHOUSE GAS REPORTING General Stationary Fuel Combustion Sources § 98.32 GHGs to report. You must report CO2, CH4, and N2O mass emissions from each stationary fuel combustion unit, except as otherwise...

  10. 40 CFR 98.32 - GHGs to report.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... GREENHOUSE GAS REPORTING General Stationary Fuel Combustion Sources § 98.32 GHGs to report. You must report CO2, CH4, and N2O mass emissions from each stationary fuel combustion unit, except as otherwise...

  11. 40 CFR 63.6610 - By what date must I conduct the initial performance tests or other initial compliance...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... initial performance tests or other initial compliance demonstrations if I own or operate a stationary RICE... performance tests or other initial compliance demonstrations if I own or operate a stationary RICE with a site... stationary RICE with a site rating of more than 500 brake HP located at a major source of HAP emissions you...

  12. 40 CFR 63.6610 - By what date must I conduct the initial performance tests or other initial compliance...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... initial performance tests or other initial compliance demonstrations if I own or operate a stationary RICE... performance tests or other initial compliance demonstrations if I own or operate a stationary RICE with a site... stationary RICE with a site rating of more than 500 brake HP located at a major source of HAP emissions you...

  13. 40 CFR 98.342 - GHGs to report.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... collection and combustion systems. (c) You must report under subpart C of this part (General Stationary Fuel Combustion Sources) the emissions of CO2, CH4, and N2O from each stationary combustion unit following the...

  14. 40 CFR 98.52 - GHGs to report.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... emissions at the facility level. (b) You must report under subpart C of this part (General Stationary Fuel Combustion Sources) the emissions of CO2, CH4, and N2O from each stationary combustion unit following the...

  15. 40 CFR 98.342 - GHGs to report.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... collection and combustion systems. (c) You must report under subpart C of this part (General Stationary Fuel Combustion Sources) the emissions of CO2, CH4, and N2O from each stationary combustion unit following the...

  16. 40 CFR 98.342 - GHGs to report.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... collection and combustion systems. (c) You must report under subpart C of this part (General Stationary Fuel Combustion Sources) the emissions of CO2, CH4, and N2O from each stationary combustion unit following the...

  17. 40 CFR 98.342 - GHGs to report.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... collection and combustion systems. (c) You must report under subpart C of this part (General Stationary Fuel Combustion Sources) the emissions of CO2, CH4, and N2O from each stationary combustion unit following the...

  18. 40 CFR 98.342 - GHGs to report.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... collection and combustion systems. (c) You must report under subpart C of this part (General Stationary Fuel Combustion Sources) the emissions of CO2, CH4, and N2O from each stationary combustion unit following the...

  19. 40 CFR 98.52 - GHGs to report.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... emissions at the facility level. (b) You must report under subpart C of this part (General Stationary Fuel Combustion Sources) the emissions of CO2, CH4, and N2O from each stationary combustion unit following the...

  20. 40 CFR 98.52 - GHGs to report.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... emissions at the facility level. (b) You must report under subpart C of this part (General Stationary Fuel Combustion Sources) the emissions of CO2, CH4, and N2O from each stationary combustion unit following the...

  1. Survey of Manual Methods of Measurements of Asbestos, Beryllium, Lead, Cadmium, Selenium, and Mercury in Stationary Source Emissions. Environmental Monitoring Series.

    ERIC Educational Resources Information Center

    Coulson, Dale M.; And Others

    The purpose of this study is to evaluate existing manual methods for analyzing asbestos, beryllium, lead, cadmium, selenium, and mercury, and from this evaluation to provide the best and most practical set of analytical methods for measuring emissions of these elements from stationary sources. The work in this study was divided into two phases.…

  2. Heat-transfer characteristics of flowing and stationary particle-bed-type fusion-reactor blankets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nietert, R.E.

    1983-02-01

    The following five appendices are included: (1) physical properties of materials, (2) thermal entrance length Nusselt number variations, (3) stationary particle bed temperature variations, (4) falling bed experimental data and calculations, and (5) stationary bed experimental data and calculations. (MOW)

  3. 40 CFR 60.4410 - How do I establish a valid parameter range if I have chosen to continuously monitor parameters?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... NEW STATIONARY SOURCES Standards of Performance for Stationary Combustion Turbines Performance Tests... of NOX emission controls in accordance with § 60.4340, the appropriate parameters must be...

  4. 40 CFR 60.4410 - How do I establish a valid parameter range if I have chosen to continuously monitor parameters?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... NEW STATIONARY SOURCES Standards of Performance for Stationary Combustion Turbines Performance Tests... of NOX emission controls in accordance with § 60.4340, the appropriate parameters must be...

  5. 40 CFR 60.4410 - How do I establish a valid parameter range if I have chosen to continuously monitor parameters?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... NEW STATIONARY SOURCES Standards of Performance for Stationary Combustion Turbines Performance Tests... of NOX emission controls in accordance with § 60.4340, the appropriate parameters must be...

  6. 40 CFR 60.4410 - How do I establish a valid parameter range if I have chosen to continuously monitor parameters?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... NEW STATIONARY SOURCES Standards of Performance for Stationary Combustion Turbines Performance Tests... of NOX emission controls in accordance with § 60.4340, the appropriate parameters must be...

  7. 40 CFR 63.6603 - What emission limitations and operating limitations must I meet if I own or operate an existing...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... operating limitations must I meet if I own or operate an existing stationary CI RICE located at an area... and operating limitations must I meet if I own or operate an existing stationary CI RICE located at an... stationary CI RICE located at an area source of HAP emissions, you must comply with the requirements in Table...

  8. 40 CFR Table 1 to Subpart Jjjj of... - NOX, CO, and VOC Emission Standards for Stationary Non-Emergency SI Engines ≥100 HP (Except...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false NOX, CO, and VOC Emission Standards for Stationary Non-Emergency SI Engines â¥100 HP (Except Gasoline and Rich Burn LPG), Stationary SI Landfill... Landfill/Digester Gas Engines, and Stationary Emergency Engines >25 HP Engine type and fuel Maximum engine...

  9. COMBUSTION AREA SOURCES: DATA SOURCES

    EPA Science Inventory

    The report identifies, documents, and evaluates data sources for stationary area source emissions, including solid waste and agricultural burning. Area source emissions of particulate matter, sulfur dioxide, oxides of nitrogen, reactive volatile organic compounds, and carbon mon...

  10. Winner-take-all in a phase oscillator system with adaptation.

    PubMed

    Burylko, Oleksandr; Kazanovich, Yakov; Borisyuk, Roman

    2018-01-11

    We consider a system of generalized phase oscillators with a central element and radial connections. In contrast to conventional phase oscillators of the Kuramoto type, the dynamic variables in our system include not only the phase of each oscillator but also the natural frequency of the central oscillator, and the connection strengths from the peripheral oscillators to the central oscillator. With appropriate parameter values the system demonstrates winner-take-all behavior in terms of the competition between peripheral oscillators for the synchronization with the central oscillator. Conditions for the winner-take-all regime are derived for stationary and non-stationary types of system dynamics. Bifurcation analysis of the transition from stationary to non-stationary winner-take-all dynamics is presented. A new bifurcation type called a Saddle Node on Invariant Torus (SNIT) bifurcation was observed and is described in detail. Computer simulations of the system allow an optimal choice of parameters for winner-take-all implementation.

  11. 76 FR 38747 - Review of New Sources and Modifications in Indian Country

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-01

    ...The EPA is finalizing a Federal Implementation Plan (FIP) under the Clean Air Act (CAA or Act) for Indian country. The FIP includes two New Source Review (NSR) regulations for the protection of air resources in Indian country. The first rule applies to new and modified minor stationary sources (minor sources) and to minor modifications at existing major stationary sources (major sources) throughout Indian country. The second rule (nonattainment major NSR rule) applies to new and modified major sources in areas of Indian country that are designated as not attaining the National Ambient Air Quality Standards (NAAQS). These rules will be implemented by EPA or a delegate Tribal agency assisting EPA with administration of the rules, until replaced by an EPA-approved implementation plan.

  12. Off-center blast in a shocked medium

    NASA Astrophysics Data System (ADS)

    Duncan-Miller, G. C.; Stone, W. D.

    2018-07-01

    When multiple blasts occur at different times, the situation arises in which a blast wave is propagating into a medium that has already been shocked. Determining the evolution in the shape of the second shock is not trivial, as it is propagating into air that is not only non-uniform, but also non-stationary. To accomplish this task, we employ the method of Kompaneets to determine the shape of a shock in a non-uniform media. We also draw from the work of Korycansky (Astrophys J 398:184-189. https://doi.org/10.1086/171847 , 1992) on an off-center explosion in a medium with radially varying density. Extending this to treat non-stationary flow, and making use of approximations to the Sedov solution for the point blast problem, we are able to determine an analytic expression for the evolving shape of the second shock. In particular, we consider the case of a shock in air at standard ambient temperature and pressure, with the second shock occurring shortly after the original blast wave reaches it, as in a sympathetic detonation.

  13. ATLAS OF SOURCE EMISSION PARTICLES

    EPA Science Inventory

    An atlas of various source emission particles characterized by electron optical techniques has been compiled for use by air pollution investigators. The particles studied were emitted by mobile, stationary, and natural sources. Sources included automobiles, manufacturing operatio...

  14. 40 CFR 70.9 - Fee determination and certification.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... determine which sources are subject to the program; (v) Emissions and ambient monitoring; (vi) Modeling... direct and indirect support to sources under the Small Business Stationary Source Technical and...

  15. Influence of carbon sources on the viability and resuscitation of Acetobacter senegalensis during high-temperature gluconic acid fermentation.

    PubMed

    Shafiei, Rasoul; Zarmehrkhorshid, Raziyeh; Mounir, Majid; Thonart, Philippe; Delvigne, Frank

    2017-05-01

    Much research has been conducted about different types of fermentation at high temperature, but only a few of them have studied cell viability changes during high-temperature fermentation. In this study, Acetobacter senegalensis, a thermo-tolerant strain, was used for gluconic acid production at 38 °C. The influences of different carbon sources and physicochemical conditions on cell viability and the resuscitation of viable but nonculturable (VBNC) cells formed during fermentation were studied. Based on the obtained results, A. senegalensis could oxidize 95 g l - 1 glucose to gluconate at 38 °C (pH 5.5, yield 83%). However, despite the availability of carbon and nitrogen sources, the specific rates of glucose consumption (q s ) and gluconate production (q p ) reduced progressively. Interestingly, gradual q s and q p reduction coincided with gradual decrease in cellular dehydrogenase activity, cell envelope integrity, and cell culturability as well as with the formation of VBNC cells. Entry of cells into VBNC state during stationary phase partly stemmed from high fermentation temperature and long-term oxidation of glucose, because just about 48% of VBNC cells formed during stationary phase were resuscitated by supplementing the culture medium with an alternative favorite carbon source (low concentration of ethanol) and/or reducing incubation temperature to 30 °C. This indicates that ethanol, as a favorable carbon source, supports the repair of stressed cells. Since formation of VBNC cells is often inevitable during high-temperature fermentation, using an alternative carbon source together with changing physicochemical conditions may enable the resuscitation of VBNC cells and their use for several production cycles.

  16. 40 CFR 97.502 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... products), and landscape or right-of-way tree trimmings. Boiler means an enclosed fossil- or other-fuel... unit means a stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine... limitation for the source for such control period. Fossil fuel means— (1) Natural gas, petroleum, coal, or...

  17. 40 CFR 97.502 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... products), and landscape or right-of-way tree trimmings. Boiler means an enclosed fossil- or other-fuel... unit means a stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine... limitation for the source for such control period. Fossil fuel means— (1) Natural gas, petroleum, coal, or...

  18. 40 CFR 97.502 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... products), and landscape or right-of-way tree trimmings. Boiler means an enclosed fossil- or other-fuel... unit means a stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine... limitation for the source for such control period. Fossil fuel means— (1) Natural gas, petroleum, coal, or...

  19. Method for removal of nitrogen oxides from stationary combustion sources

    NASA Technical Reports Server (NTRS)

    Cooper, Charles D. (Inventor); Collins, Michelle M. (Inventor); Clausen, III, Christian A. (Inventor)

    2004-01-01

    A method for removing NO.sub.X from gas streams emanating from stationary combustion sources and manufacturing plants utilizes the injection of hydrogen peroxide into the gas stream for rapid gas-phase oxidation of NO to NO.sub.2 and water-soluble nitrogen acids HNO.sub.2 and HNO.sub.3. The nitrogen acids may be removed from the oxidized gas stream by wet scrubbing or by contact with a particulate alkaline material to form a nitrite/nitrate salt.

  20. Recent development of ionic liquid stationary phases for liquid chromatography.

    PubMed

    Shi, Xianzhe; Qiao, Lizhen; Xu, Guowang

    2015-11-13

    Based on their particular physicochemical characteristics, ionic liquids have been widely applied in many fields of analytical chemistry. Many types of ionic liquids were immobilized on a support like silica or monolith as stationary phases for liquid chromatography. Moreover, different approaches were developed to bond covalently ionic liquids onto the supporting materials. The obtained ionic liquid stationary phases show multi-mode mechanism including hydrophobic, hydrophilic, hydrogen bond, anion exchange, π-π, and dipole-dipole interactions. Therefore, they could be used in different chromatographic modes including ion-exchange, RPLC, NPLC and HILIC to separate various classes of compounds. This review mainly summarizes the immobilized patterns and types of ionic liquid stationary phases, their retention mechanisms and applications in the recent five years. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Momeni, D.; Ramazani-Arani, R.; Nouri-Zonoz, M.

    Using the Ehlers transformation along with the gravitoelectromagnetic approach to stationary spacetimes we start from the Morgan-Morgan disk spacetime (without radial pressure) as the seed metric and find its corresponding stationary spacetime. As expected from the Ehlers transformation the stationary spacetime obtained suffers from a NUT-type singularity and the new parameter introduced in the stationary case could be interpreted as the gravitomagnetic monopole charge (or the NUT factor). Some of the properties of this spacetime including its particle velocity distribution, gravitational redshift, stability, and energy conditions are discussed.

  2. ADVANCED COMBUSTION SYSTEMS FOR STATIONARY GAS TURBINE ENGINES: VOLUME I. REVIEW AND PRELIMINARY EVALUATION

    EPA Science Inventory

    The reports describe an exploratory development program to identify, evaluate, and demonstrate dry techniques for significantly reducing NOx from thermal and fuel-bound sources in stationary gas turbine engines. Volume 1 covers Phase I of the four-phase effort. In Phase I, duty c...

  3. Impact of air pollution on pulmonary function and respiratory symptoms in children. Longitudinal repeated-measures study.

    PubMed

    Linares, Benigno; Guizar, Juan M; Amador, Norma; Garcia, Alfonso; Miranda, Victor; Perez, Jose R; Chapela, Rocío

    2010-11-24

    Salamanca, Mexico occupied fourth place nationally in contaminating emissions. The aim of the study was to determine the impact of air pollution on the frequency of pulmonary function alterations and respiratory symptoms in school-age children in a longitudinal repeated-measures study. We recruited a cohort of 464 children from 6 to 14 years of age, from two schools differing in distance from the major stationary air pollution sources. Spirometry, respiratory symptoms and air pollutants (O3, SO2, NO, NO2, NOx, PM10,) were obtained for each season. Mixed models for continuous variables and multilevel logistic regression for respiratory symptoms were fitted taking into account seasonal variations in health effects according to air pollution levels. Abnormalities in lung function and frequency of respiratory symptoms were higher in the school closer to major stationary air pollution sources than in the distant school. However, in winter differences on health disappeared. The principal alteration in lung function was the obstructive type, which frequency was greater in those students with greater exposure (10.4% vs. 5.3%; OR = 1.95, 95% CI 1.0-3.7), followed by the mixed pattern also more frequent in the same students (4.1% vs. 0.9%; OR = 4.69, 95% CI, 1.0-21.1). PM10 levels were the most consistent factor with a negative relationship with FVC, FEV1 and PEF but with a positive relationship with FEV1/FVC coefficient according to its change per 3-month period. Students from the school closer to major stationary air pollution sources had in general more respiratory symptoms than those from the distant school. However, in winter air pollution was generalized in this city and differences in health disappeared. PM10 levels were the most consistent factor related to pulmonary function according, to its change per 3-month period.

  4. Generation of an endogenous DNA-methylating agent by nitrosation in Escherichia coli.

    PubMed Central

    Taverna, P; Sedgwick, B

    1996-01-01

    Escherichia coli ada ogt mutants, which are totally deficient in O6-methylguanine-DNA methyltransferases, have an increased spontaneous mutation rate. This phenotype is particularly evident in starving cells and suggests the generation of an endogenous DNA alkylating agent under this growth condition. We have found that in wild-type cells, the level of the inducible Ada protein is 20-fold higher in stationary-phase and starving cells than in rapidly growing cells, thus enhancing the defense of these cells against DNA damage. The increased level of Ada in stationary cells is dependent on RpoS, a stationary-phase-specific sigma subunit of RNA polymerase. We have also identified a potential source of the mutagenic agent. Nitrosation of amides and related compounds can generate directly acting methylating agents and can be catalyzed by bacteria] enzymes. E. coli moa mutants, which are defective in the synthesis of a molybdopterin cofactor required by several reductases, are deficient in nitrosation activity. It is reported here that a moa mutant shows reduced generation of a mutagenic methylating agent from methylamine (or methylurea) and nitrite added to agar plates. Moreover, a moa mutation eliminates much of the spontaneous mutagenesis in ada ogt mutants. These observations indicate that the major endogenous mutagen is not S-adenosylmethionine but arises by bacterially catalyzed nitrosation. PMID:8752326

  5. Study of Integrated USV/UUV Observation System Performance in Monterey Bay

    DTIC Science & Technology

    2017-09-01

    5 IV. EXPERIMENTAL SETUP... quasi -stationary at depth in low-current environments. This thesis evaluates the performance of deep sensors in determining behavior of a moving source...acoustic sensors that would be quasi -stationary receivers when in drift mode at depth in low current environments. One key advantage to this technique is

  6. 40 CFR 63.9983 - Are any EGUs not subject to this subpart?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., recirculated flue gases or exhaust gases from other sources (such as stationary gas turbines, internal... subject to this subpart. (a) Any unit designated as a stationary combustion turbine, other than an... utility steam generating unit that is not a coal- or oil-fired EGU and combusts natural gas for more than...

  7. 40 CFR 63.9983 - Are any EGUs not subject to this subpart?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., recirculated flue gases or exhaust gases from other sources (such as stationary gas turbines, internal... subject to this subpart. (a) Any unit designated as a stationary combustion turbine, other than an... utility steam generating unit that is not a coal- or oil-fired EGU and combusts natural gas for more than...

  8. 40 CFR 63.9983 - Are any EGUs not subject to this subpart?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., recirculated flue gases or exhaust gases from other sources (such as stationary gas turbines, internal... subject to this subpart. (a) Any unit designated as a stationary combustion turbine, other than an... utility steam generating unit that is not a coal- or oil-fired EGU and combusts natural gas for more than...

  9. Multiepoch VLBI observations of 4C 39.25 - Superluminal motion amid stationary structure

    NASA Technical Reports Server (NTRS)

    Shaffer, David B.; Marscher, Alan P.; Marcaide, Jon; Romney, Jonathan D.

    1987-01-01

    Eight VLBI maps of the quasar 4C 39.25 are presented, covering the time interval November 1979 to July 1985. During this period the compact components at the eastern and western ends of the source remained roughly stationary with respect to each other. A third component emerged from the western component in 1982 and proceeded to move (relative to the other two components) eastward at a rate of 0.16 + or - 0.02 marcsec per year. This corresponds to an average apparent speed between 3.2c and 8.4c for Hubble's constant between 100 and 50 km/s Mpc and q0 between 1 and 0. This superluminal motion contrasts with the stationary structure observed in the 1970s and also still observed between the eastern and western ends of the source. Possible explanations include superluminal feeding of a stationary compact counterpart to a classical radio lobe, an obstacle in a relativistic jet, a relativistic jet which alternatively expands and contracts owing to gradients in the confining pressure, and gravitational lensing of the compact radio emission.

  10. Trends of Occupational Fatalities Involving Machines, United States, 1992–2010

    PubMed Central

    Marsh, Suzanne M.; Fosbroke, David E.

    2016-01-01

    Background This paper describes trends of occupational machine-related fatalities from 1992–2010. We examine temporal patterns by worker demographics, machine types (e.g., stationary, mobile), and industries. Methods We analyzed fatalities from Census of Fatal Occupational Injuries data provided by the Bureau of Labor Statistics to the National Institute for Occupational Safety and Health. We used injury source to identify machine-related incidents and Poisson regression to assess trends over the 19-year period. Results There was an average annual decrease of 2.8% in overall machine-related fatality rates from 1992 through 2010. Mobile machine-related fatality rates decreased an average of 2.6% annually and stationary machine-related rates decreased an average of 3.5% annually. Groups that continued to be at high risk included older workers; self-employed; and workers in agriculture/forestry/fishing, construction, and mining. Conclusion Addressing dangers posed by tractors, excavators, and other mobile machines needs to continue. High-risk worker groups should receive targeted information on machine safety. PMID:26358658

  11. Pattern formation in nonextensive thermodynamics: selection criterion based on the Renyi entropy production.

    PubMed

    Cybulski, Olgierd; Matysiak, Daniel; Babin, Volodymyr; Holyst, Robert

    2005-05-01

    We analyze a system of two different types of Brownian particles confined in a cubic box with periodic boundary conditions. Particles of different types annihilate when they come into close contact. The annihilation rate is matched by the birth rate, thus the total number of each kind of particles is conserved. When in a stationary state, the system is divided by an interface into two subregions, each occupied by one type of particles. All possible stationary states correspond to the Laplacian eigenfunctions. We show that the system evolves towards those stationary distributions of particles which minimize the Renyi entropy production. In all cases, the Renyi entropy production decreases monotonically during the evolution despite the fact that the topology and geometry of the interface exhibit abrupt and violent changes.

  12. SOURCEBOOK: NOX CONTROL TECHNOLOGY DATA

    EPA Science Inventory

    The report, a compilation of available information on the control of nitrogen oxide (NOx) emissions from stationary sources, is provided to assist new source permitting activities by regulatory agencies. he sources covered are combustion turbines, internal combustion engines, non...

  13. Reverberation effects on directionality and response of stationary monopole and dipole sources in a wind tunnel

    NASA Technical Reports Server (NTRS)

    Baumeister, K. J.

    1985-01-01

    Analytical solutions for the three dimensional inhomogeneous wave equation with flow in a hardwall rectangular wind tunnel and in the free field are presented for a stationary monopole noise source. Dipole noise sources are calculated by combining two monopoles 180 deg out of phase. Numerical calculations for the modal content, spectral response and directivity for both monopole and dipole sources are presented. In addition, the effect of tunnel alterations, such as the addition of a mounting plate, on the tunnels reverberant response are considered. In the frequency range of practical importance for the turboprop response, important features of the free field directivity can be approximated in a hardwall wind tunnel with flow if the major lobe of the noise source is not directed upstream. However, for an omnidirectional source, such as a monopole, the hardwall wind tunnel and free field response are not comparable.

  14. Research and development of a field-ready protocol for sampling of phosgene from stationary source emissions: Diethylamine reagent studies. Research report, 11 July 1995--30 September 1996

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steger, J.L.; Bursey, J.T.; Merrill, R.G.

    1999-03-01

    This report presents the results of laboratory studies to develop and evaluate a method for the sampling and analysis of phosgene from stationary sources of air emissions using diethylamine (DEA) in toluene as the collection media. The method extracts stack gas from emission sources and stabilizes the reactive gas for subsequent analysis. DEA was evaluated both in a benchtop study and in a laboratory train spiking study. This report includes results for both the benchtop study and the train spiking study. Benchtop studies to evaluate the suitability of DEA for collecting and analyzing phosgene investigated five variables: storage time, DEAmore » concentration, moisture/pH, phosgene concentration, and sample storage temperature. Prototype sampling train studies were performed to determine if the benchtop chemical studies were transferable to a Modified Method 5 sampling train collecting phosgene in the presence of clean air mixed with typical stack gas components. Four conditions, which varied the moisture and phosgene spike were evaluated in triplicate. In addition to research results, the report includes a detailed draft method for sampling and analysis of phosgene from stationary source emissions.« less

  15. Service equipment for use in hostile environments

    NASA Technical Reports Server (NTRS)

    Dolce, James L. (Inventor); Gordon, Andrew L. (Inventor)

    1994-01-01

    Service equipment for use in hostile environments includes a detachable service unit secured to a stationary service unit. The detachable service unit includes a housing with an exterior plate, a power control interface for connection to an exterior power source, locating pins located in said exterior plate, an electrical connector in the exterior plate electrically coupled to said power control interface, and a pair of clamping receptacles formed in the exterior plate and located on adjacent opposite edges of the exterior plate. The stationary unit includes an electrical connector for connection to the electrical connector of the detachable service unit, a clamping apparatus for clamping and unclamping the detachable service unit from the stationary unit, a base clamp assembly for mounting the clamping apparatus onto the stationary unit, and locating pin holes for receiving the locating pins and aligning the detachable service unit onto the stationary unit. The detachable service unit and stationary unit have mating scalloped faces which aid in alignment and provide a mechanism for heat dissipation.

  16. Air Pollution Emissions Overview | Air Quality Planning & ...

    EPA Pesticide Factsheets

    2016-06-08

    Air pollution comes from many different sources: stationary sources such as factories, power plants, and smelters and smaller sources such as dry cleaners and degreasing operations; mobile sources such as cars, buses, planes, trucks, and trains; and naturally occurring sources such as windblown dust, and volcanic eruptions, all contribute to air pollution.

  17. System identification through nonstationary data using Time-Frequency Blind Source Separation

    NASA Astrophysics Data System (ADS)

    Guo, Yanlin; Kareem, Ahsan

    2016-06-01

    Classical output-only system identification (SI) methods are based on the assumption of stationarity of the system response. However, measured response of buildings and bridges is usually non-stationary due to strong winds (e.g. typhoon, and thunder storm etc.), earthquakes and time-varying vehicle motions. Accordingly, the response data may have time-varying frequency contents and/or overlapping of modal frequencies due to non-stationary colored excitation. This renders traditional methods problematic for modal separation and identification. To address these challenges, a new SI technique based on Time-Frequency Blind Source Separation (TFBSS) is proposed. By selectively utilizing "effective" information in local regions of the time-frequency plane, where only one mode contributes to energy, the proposed technique can successfully identify mode shapes and recover modal responses from the non-stationary response where the traditional SI methods often encounter difficulties. This technique can also handle response with closely spaced modes which is a well-known challenge for the identification of large-scale structures. Based on the separated modal responses, frequency and damping can be easily identified using SI methods based on a single degree of freedom (SDOF) system. In addition to the exclusive advantage of handling non-stationary data and closely spaced modes, the proposed technique also benefits from the absence of the end effects and low sensitivity to noise in modal separation. The efficacy of the proposed technique is demonstrated using several simulation based studies, and compared to the popular Second-Order Blind Identification (SOBI) scheme. It is also noted that even some non-stationary response data can be analyzed by the stationary method SOBI. This paper also delineates non-stationary cases where SOBI and the proposed scheme perform comparably and highlights cases where the proposed approach is more advantageous. Finally, the performance of the proposed method is evaluated using a full-scale non-stationary response of a tall building during an earthquake and found it to perform satisfactorily.

  18. 40 CFR 98.30 - Definition of the source category.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., boilers, simple and combined-cycle combustion turbines, engines, incinerators, and process heaters. (b... (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING General Stationary Fuel Combustion Sources § 98.30 Definition...

  19. X-ray diagnostics of massive star winds

    NASA Astrophysics Data System (ADS)

    Oskinova, L. M.; Ignace, R.; Huenemoerder, D. P.

    2017-11-01

    Observations with powerful X-ray telescopes, such as XMM-Newton and Chandra, significantly advance our understanding of massive stars. Nearly all early-type stars are X-ray sources. Studies of their X-ray emission provide important diagnostics of stellar winds. High-resolution X-ray spectra of O-type stars are well explained when stellar wind clumping is taking into account, providing further support to a modern picture of stellar winds as non-stationary, inhomogeneous outflows. X-ray variability is detected from such winds, on time scales likely associated with stellar rotation. High-resolution X-ray spectroscopy indicates that the winds of late O-type stars are predominantly in a hot phase. Consequently, X-rays provide the best observational window to study these winds. X-ray spectroscopy of evolved, Wolf-Rayet type, stars allows to probe their powerful metal enhanced winds, while the mechanisms responsible for the X-ray emission of these stars are not yet understood.

  20. 40 CFR 98.322 - GHGs to report.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Stationary Fuel Combustion Sources) the CO2, CH4, and N2O emissions from each stationary fuel combustion unit... emissions from ventilation and degasification systems. (d) You must report under this subpart the CO2 emissions from coal mine gas CH4 destruction occuring at the facility, where the gas is not a fuel input for...

  1. 40 CFR 98.322 - GHGs to report.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Stationary Fuel Combustion Sources) the CO2, CH4, and N2O emissions from each stationary fuel combustion unit... emissions from ventilation and degasification systems. (d) You must report under this subpart the CO2 emissions from coal mine gas CH4 destruction occuring at the facility, where the gas is not a fuel input for...

  2. 40 CFR 98.112 - GHGs to report.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... GREENHOUSE GAS REPORTING Ferroalloy Production § 98.112 GHGs to report. You must report: (a) Process CO2... Table K-1 to subpart K. (b) CO2, CH4, and N2O emissions from each stationary combustion unit following... part (General Stationary Fuel Combustion Sources). [74 FR 56374, Oct. 30, 2009, as amended at 75 FR...

  3. 40 CFR 98.322 - GHGs to report.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Stationary Fuel Combustion Sources) the CO2, CH4, and N2O emissions from each stationary fuel combustion unit... emissions from ventilation and degasification systems. (d) You must report under this subpart the CO2 emissions from coal mine gas CH4 destruction occuring at the facility, where the gas is not a fuel input for...

  4. 40 CFR 98.112 - GHGs to report.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... GREENHOUSE GAS REPORTING Ferroalloy Production § 98.112 GHGs to report. You must report: (a) Process CO2... Table K-1 to subpart K. (b) CO2, CH4, and N2O emissions from each stationary combustion unit following... part (General Stationary Fuel Combustion Sources). [74 FR 56374, Oct. 30, 2009, as amended at 75 FR...

  5. 40 CFR 98.112 - GHGs to report.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... GREENHOUSE GAS REPORTING Ferroalloy Production § 98.112 GHGs to report. You must report: (a) Process CO2... Table K-1 to subpart K. (b) CO2, CH4, and N2O emissions from each stationary combustion unit following... part (General Stationary Fuel Combustion Sources). [74 FR 56374, Oct. 30, 2009, as amended at 75 FR...

  6. 40 CFR 98.112 - GHGs to report.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... GREENHOUSE GAS REPORTING Ferroalloy Production § 98.112 GHGs to report. You must report: (a) Process CO2... Table K-1 to subpart K. (b) CO2, CH4, and N2O emissions from each stationary combustion unit following... part (General Stationary Fuel Combustion Sources). [74 FR 56374, Oct. 30, 2009, as amended at 75 FR...

  7. 40 CFR 60.4390 - What are my reporting requirements if I operate an emergency combustion turbine or a research and...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... operate an emergency combustion turbine or a research and development turbine? 60.4390 Section 60.4390... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Stationary Combustion Turbines Reporting § 60.4390 What are my reporting requirements if I operate an emergency combustion turbine or a research...

  8. 40 CFR 60.4390 - What are my reporting requirements if I operate an emergency combustion turbine or a research and...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... operate an emergency combustion turbine or a research and development turbine? 60.4390 Section 60.4390... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Stationary Combustion Turbines Reporting § 60.4390 What are my reporting requirements if I operate an emergency combustion turbine or a research...

  9. 40 CFR 60.4390 - What are my reporting requirements if I operate an emergency combustion turbine or a research and...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... operate an emergency combustion turbine or a research and development turbine? 60.4390 Section 60.4390... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Stationary Combustion Turbines Reporting § 60.4390 What are my reporting requirements if I operate an emergency combustion turbine or a research...

  10. 40 CFR 60.4390 - What are my reporting requirements if I operate an emergency combustion turbine or a research and...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... operate an emergency combustion turbine or a research and development turbine? 60.4390 Section 60.4390... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Stationary Combustion Turbines Reporting § 60.4390 What are my reporting requirements if I operate an emergency combustion turbine or a research...

  11. 40 CFR 60.4390 - What are my reporting requirements if I operate an emergency combustion turbine or a research and...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... operate an emergency combustion turbine or a research and development turbine? 60.4390 Section 60.4390... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Stationary Combustion Turbines Reporting § 60.4390 What are my reporting requirements if I operate an emergency combustion turbine or a research...

  12. 40 CFR 60.4345 - What are the requirements for the continuous emission monitoring system equipment, if I choose to...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... continuous emission monitoring system equipment, if I choose to use this option? 60.4345 Section 60.4345... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Stationary Combustion Turbines Monitoring § 60.4345 What are the requirements for the continuous emission monitoring system equipment, if I...

  13. 40 CFR 60.4345 - What are the requirements for the continuous emission monitoring system equipment, if I choose to...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... continuous emission monitoring system equipment, if I choose to use this option? 60.4345 Section 60.4345... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Stationary Combustion Turbines Monitoring § 60.4345 What are the requirements for the continuous emission monitoring system equipment, if I...

  14. Printing and Publishing Monitoring Information

    EPA Pesticide Factsheets

    Stationary source emissions monitoring is required to demonstrate that a source is meeting the requirements in Federal or state rules. This page covers monitoring information specific to the printing and publishing industry.

  15. Monitoring by Control Technique - Cyclone

    EPA Pesticide Factsheets

    Stationary source emissions monitoring is required to demonstrate that a source is meeting the requirements in Federal or state rules. This page is about cyclone control techniques used to reduce pollutant emissions.

  16. Monitoring by Control Technique - Condensers

    EPA Pesticide Factsheets

    Stationary source emissions monitoring is required to demonstrate that a source is meeting the requirements in Federal or state rules. This page is about condenser control techniques used to reduce pollutant emissions.

  17. Magnetic fields and flows between 1 AU and 0.3 AU during the primary mission of HELIOS 1

    NASA Technical Reports Server (NTRS)

    Burlaga, L. F.; Ness, N. F.; Mariani, F.; Bavassano, B.; Villante, U.; Rosenbauer, H.; Schwenn, R.; Harvey, J.

    1978-01-01

    The recurrent flow and field patterns observed by HELIOS 1, and the relation between these patterns and coronal holes are discussed. Four types of recurrent patterns were observed: a large recurrent stream, a recurrent slow (quiet) flow, a rapidly evolving flow, and a recurrent compound stream. There recurrent streams were not stationary, for although the sources recurred at approximately the same longitudes on successive rotations, the shapes and latitudinal patterns changed from one rotation to the next. A type of magnetic field and plasma structure characterized by a low ion temperature and a high magnetic field intensity is described as well as the structures of stream boundaries between the sun at approximately 0.3 AU.

  18. Ground Penetrating Radar as a Contextual Sensor for Multi-Sensor Radiological Characterisation

    PubMed Central

    Ukaegbu, Ikechukwu K.; Gamage, Kelum A. A.

    2017-01-01

    Radioactive sources exist in environments or contexts that influence how they are detected and localised. For instance, the context of a moving source is different from a stationary source because of the effects of motion. The need to incorporate this contextual information in the radiation detection and localisation process has necessitated the integration of radiological and contextual sensors. The benefits of the successful integration of both types of sensors is well known and widely reported in fields such as medical imaging. However, the integration of both types of sensors has also led to innovative solutions to challenges in characterising radioactive sources in non-medical applications. This paper presents a review of such recent applications. It also identifies that these applications mostly use visual sensors as contextual sensors for characterising radiation sources. However, visual sensors cannot retrieve contextual information about radioactive wastes located in opaque environments encountered at nuclear sites, e.g., underground contamination. Consequently, this paper also examines ground-penetrating radar (GPR) as a contextual sensor for characterising this category of wastes and proposes several ways of integrating data from GPR and radiological sensors. Finally, it demonstrates combined GPR and radiation imaging for three-dimensional localisation of contamination in underground pipes using radiation transport and GPR simulations. PMID:28387706

  19. A de-noising algorithm based on wavelet threshold-exponential adaptive window width-fitting for ground electrical source airborne transient electromagnetic signal

    NASA Astrophysics Data System (ADS)

    Ji, Yanju; Li, Dongsheng; Yu, Mingmei; Wang, Yuan; Wu, Qiong; Lin, Jun

    2016-05-01

    The ground electrical source airborne transient electromagnetic system (GREATEM) on an unmanned aircraft enjoys considerable prospecting depth, lateral resolution and detection efficiency, etc. In recent years it has become an important technical means of rapid resources exploration. However, GREATEM data are extremely vulnerable to stationary white noise and non-stationary electromagnetic noise (sferics noise, aircraft engine noise and other human electromagnetic noises). These noises will cause degradation of the imaging quality for data interpretation. Based on the characteristics of the GREATEM data and major noises, we propose a de-noising algorithm utilizing wavelet threshold method and exponential adaptive window width-fitting. Firstly, the white noise is filtered in the measured data using the wavelet threshold method. Then, the data are segmented using data window whose step length is even logarithmic intervals. The data polluted by electromagnetic noise are identified within each window based on the discriminating principle of energy detection, and the attenuation characteristics of the data slope are extracted. Eventually, an exponential fitting algorithm is adopted to fit the attenuation curve of each window, and the data polluted by non-stationary electromagnetic noise are replaced with their fitting results. Thus the non-stationary electromagnetic noise can be effectively removed. The proposed algorithm is verified by the synthetic and real GREATEM signals. The results show that in GREATEM signal, stationary white noise and non-stationary electromagnetic noise can be effectively filtered using the wavelet threshold-exponential adaptive window width-fitting algorithm, which enhances the imaging quality.

  20. A Dancing Black Hole

    NASA Astrophysics Data System (ADS)

    Shoemaker, Deirdre; Smith, Kenneth; Schnetter, Erik; Fiske, David; Laguna, Pablo; Pullin, Jorge

    2002-04-01

    Recently, stationary black holes have been successfully simulated for up to times of approximately 600-1000M, where M is the mass of the black hole. Considering that the expected burst of gravitational radiation from a binary black hole merger would last approximately 200-500M, black hole codes are approaching the point where simulations of mergers may be feasible. We will present two types of simulations of single black holes obtained with a code based on the Baumgarte-Shapiro-Shibata-Nakamura formulation of the Einstein evolution equations. One type of simulations addresses the stability properties of stationary black hole evolutions. The second type of simulations demonstrates the ability of our code to move a black hole through the computational domain. This is accomplished by shifting the stationary black hole solution to a coordinate system in which the location of the black hole is time dependent.

  1. Outlier Resistant Predictive Source Encoding for a Gaussian Stationary Nominal Source.

    DTIC Science & Technology

    1987-09-18

    breakdown point and influence function . The proposed sequence of predictive encoders attains strictly positive breakdown point and uniformly bounded... influence function , at the expense of increased mean difference-squared distortion and differential entropy, at the Gaussian nominal source.

  2. Air Quality Planning & Standards | Air & Radiation | US EPA

    EPA Pesticide Factsheets

    2016-10-18

    Air pollution comes from many different sources: stationary sources such as factories, power plants, and smelters and smaller sources such as dry cleaners and degreasing operations; mobile sources such as cars, buses, planes, trucks, and trains; and naturally occurring sources such as windblown dust, and volcanic eruptions, all contribute to air pollution.

  3. Air Quality | Air Quality Planning & Standards | US EPA

    EPA Pesticide Factsheets

    2016-06-08

    Air pollution comes from many different sources: stationary sources such as factories, power plants, and smelters and smaller sources such as dry cleaners and degreasing operations; mobile sources such as cars, buses, planes, trucks, and trains; and naturally occurring sources such as windblown dust, and volcanic eruptions, all contribute to air pollution.

  4. Minimization of the Renyi entropy production in the space-partitioning process.

    PubMed

    Cybulski, O; Babin, V; Hołyst, R

    2005-04-01

    The spontaneous division of space in Fleming-Viot processes is studied in terms of non-extensive thermodynamics. We analyze a system of n different types of Brownian particles confined in a box. Particles of different types annihilate each other when they come into close contact. Each process of annihilation is accompanied by a simultaneous nucleation of a particle of the same type, so that the number of particles of each component remains constant. The system eventually reaches a stationary state, in which the available space is divided into n separate subregions, each occupied by particles of one type. Within each subregion, the particle density distribution minimizes the Renyi entropy production. We show that the sum of these entropy productions in the stationary state is also minimized, i.e., the resulting boundaries between different components adopt a configuration which minimizes the total entropy production. The evolution of the system leads to decreasing of the total entropy production monotonically in time, irrespective of the initial conditions. In some circumstances, the stationary state is not unique-the entropy production may have several local minima for different configurations. In the case of a rectangular box, the existence and stability of different stationary states are studied as a function of the aspect ratio of the rectangle.

  5. 40 CFR 63.4081 - Am I subject to this subpart?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... source or group of stationary sources located within a contiguous area and under common control that... sources located within a contiguous area and under common control that is not a major source. (b) The..., spray guns or dip tanks; (4) Application of porcelain enamel, powder coating, and asphalt interior...

  6. 40 CFR 63.4081 - Am I subject to this subpart?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... source or group of stationary sources located within a contiguous area and under common control that... sources located within a contiguous area and under common control that is not a major source. (b) The..., spray guns or dip tanks; (4) Application of porcelain enamel, powder coating, and asphalt interior...

  7. 40 CFR 63.4081 - Am I subject to this subpart?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... source or group of stationary sources located within a contiguous area and under common control that... sources located within a contiguous area and under common control that is not a major source. (b) The..., spray guns or dip tanks; (4) Application of porcelain enamel, powder coating, and asphalt interior...

  8. Monitoring by Control Technique - Catalytic Oxidizer

    EPA Pesticide Factsheets

    Stationary source emissions monitoring is required to demonstrate that a source is meeting the requirements in Federal or state rules. This page is about catalytic oxidizer control techniques used to reduce pollutant emissions.

  9. Monitoring by Control Technique - Thermal Oxidizer

    EPA Pesticide Factsheets

    Stationary source emissions monitoring is required to demonstrate that a source is meeting the requirements in Federal or state rules. This page is about thermal oxidizer control techniques used to reduce pollutant emissions.

  10. Monitoring by Control Technique - Electrostatic Precipitators

    EPA Pesticide Factsheets

    Stationary source emissions monitoring is required to demonstrate that a source is meeting the requirements in Federal or state rules. This page is about electrostatic precipitator control techniques used to reduce pollutant emissions.

  11. Monitoring by Control Technique - Fabric Filters

    EPA Pesticide Factsheets

    Stationary source emissions monitoring is required to demonstrate that a source is meeting the requirements in Federal or state rules. This page is about fabric filter control techniques used to reduce pollutant emissions.

  12. Monitoring by Control Technique - Capture Systems

    EPA Pesticide Factsheets

    Stationary source emissions monitoring is required to demonstrate that a source is meeting the requirements in Federal or state rules. This page is about capture system control techniques used to reduce pollutant emissions.

  13. 40 CFR 49.125 - Rule for limiting the emissions of particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., gaseous fuel, heat input, incinerator, marine vessel, mobile sources, motor vehicle, nonroad engine..., residual fuel oil, solid fuel, stack, standard conditions, stationary source, uncombined water, used oil...

  14. 40 CFR 49.125 - Rule for limiting the emissions of particulate matter.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., gaseous fuel, heat input, incinerator, marine vessel, mobile sources, motor vehicle, nonroad engine..., residual fuel oil, solid fuel, stack, standard conditions, stationary source, uncombined water, used oil...

  15. Modelling of Hydrophilic Interaction Liquid Chromatography Stationary Phases Using Chemometric Approaches

    PubMed Central

    Ortiz-Villanueva, Elena; Tauler, Romà

    2017-01-01

    Metabolomics is a powerful and widely used approach that aims to screen endogenous small molecules (metabolites) of different families present in biological samples. The large variety of compounds to be determined and their wide diversity of physical and chemical properties have promoted the development of different types of hydrophilic interaction liquid chromatography (HILIC) stationary phases. However, the selection of the most suitable HILIC stationary phase is not straightforward. In this work, four different HILIC stationary phases have been compared to evaluate their potential application for the analysis of a complex mixture of metabolites, a situation similar to that found in non-targeted metabolomics studies. The obtained chromatographic data were analyzed by different chemometric methods to explore the behavior of the considered stationary phases. ANOVA-simultaneous component analysis (ASCA), principal component analysis (PCA) and partial least squares regression (PLS) were used to explore the experimental factors affecting the stationary phase performance, the main similarities and differences among chromatographic conditions used (stationary phase and pH) and the molecular descriptors most useful to understand the behavior of each stationary phase. PMID:29064436

  16. Primary Beam Air Kerma Dependence on Distance from Cargo and People Scanners

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strom, Daniel J.; Cerra, Frank

    The distance dependence of air kerma or dose rate of the primary radiation beam is not obvious for security scanners of cargo and people in which there is relative motion between a collimated source and the person or object being imaged. To study this problem, one fixed line source and three moving-source scan-geometry cases are considered, each characterized by radiation emanating perpendicular to an axis. The cases are 1) a stationary line source of radioactive material, e.g., contaminated solution in a pipe; 2) a moving, uncollimated point source of radiation that is shuttered or off when it is stationary; 3)more » a moving, collimated point source of radiation that is shuttered or off when it is stationary; and 4) a translating, narrow “pencil” beam emanating in a flying-spot, raster pattern. Each case is considered for short and long distances compared to the line source length or path traversed by a moving source. The short distance model pertains mostly to dose to objects being scanned and personnel associated with the screening operation. The long distance model pertains mostly to potential dose to bystanders. For radionuclide sources, the number of nuclear transitions that occur a) per unit length of a line source, or b) during the traversal of a point source, is a unifying concept. The “universal source strength” of air kerma rate at a meter from the source can be used to describe x-ray machine or radionuclide sources. For many cargo and people scanners with highly collimated fan or pencil beams, dose varies as the inverse of the distance from the source in the near field and with the inverse square of the distance beyond a critical radius. Ignoring the inverse square dependence and using inverse distance dependence is conservative in the sense of tending to overestimate dose.« less

  17. Primary Beam Air Kerma Dependence on Distance from Cargo and People Scanners.

    PubMed

    Strom, Daniel J; Cerra, Frank

    2016-06-01

    The distance dependence of air kerma or dose rate of the primary radiation beam is not obvious for security scanners of cargo and people in which there is relative motion between a collimated source and the person or object being imaged. To study this problem, one fixed line source and three moving-source scan-geometry cases are considered, each characterized by radiation emanating perpendicular to an axis. The cases are 1) a stationary line source of radioactive material, e.g., contaminated solution in a pipe; 2) a moving, uncollimated point source of radiation that is shuttered or off when it is stationary; 3) a moving, collimated point source of radiation that is shuttered or off when it is stationary; and 4) a translating, narrow "pencil" beam emanating in a flying-spot, raster pattern. Each case is considered for short and long distances compared to the line source length or path traversed by a moving source. The short distance model pertains mostly to dose to objects being scanned and personnel associated with the screening operation. The long distance model pertains mostly to potential dose to bystanders. For radionuclide sources, the number of nuclear transitions that occur a) per unit length of a line source or b) during the traversal of a point source is a unifying concept. The "universal source strength" of air kerma rate at 1 m from the source can be used to describe x-ray machine or radionuclide sources. For many cargo and people scanners with highly collimated fan or pencil beams, dose varies as the inverse of the distance from the source in the near field and with the inverse square of the distance beyond a critical radius. Ignoring the inverse square dependence and using inverse distance dependence is conservative in the sense of tending to overestimate dose.

  18. Stationary states in quantum walk search

    NASA Astrophysics Data System (ADS)

    PrÅ«sis, Krišjānis; Vihrovs, Jevgěnijs; Wong, Thomas G.

    2016-09-01

    When classically searching a database, having additional correct answers makes the search easier. For a discrete-time quantum walk searching a graph for a marked vertex, however, additional marked vertices can make the search harder by causing the system to approximately begin in a stationary state, so the system fails to evolve. In this paper, we completely characterize the stationary states, or 1-eigenvectors, of the quantum walk search operator for general graphs and configurations of marked vertices by decomposing their amplitudes into uniform and flip states. This infinitely expands the number of known stationary states and gives an optimization procedure to find the stationary state closest to the initial uniform state of the walk. We further prove theorems on the existence of stationary states, with them conditionally existing if the marked vertices form a bipartite connected component and always existing if nonbipartite. These results utilize the standard oracle in Grover's algorithm, but we show that a different type of oracle prevents stationary states from interfering with the search algorithm.

  19. SOURCE ASSESSMENT: PRIORITIZATION OF STATIONARY WATER POLLUTION SOURCES

    EPA Science Inventory

    The report gives priority lists to aid in selecting specific sources of water effluents for detailed assessment. It describes the general water prioritization model, explains its implementation, and gives a detailed example of its use. It describes hazard factors that were develo...

  20. 40 CFR 63.360 - Applicability.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES Ethylene Oxide Emissions Standards... subpart does not apply to ethylene oxide sterilization operations at stationary sources such as hospitals... sterilization chamber vents at sources using less than 1 ton of ethylene oxide that increase their ethylene...

  1. 40 CFR 63.6590 - What parts of my plant does this subpart cover?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) Existing spark ignition 2 stroke lean burn (2SLB) stationary RICE with a site rating of more than 500 brake HP located at a major source of HAP emissions; (ii) Existing spark ignition 4 stroke lean burn (4SLB... emissions; (4) A new or reconstructed spark ignition 4 stroke rich burn (4SRB) stationary RICE with a site...

  2. 40 CFR 63.6590 - What parts of my plant does this subpart cover?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) Existing spark ignition 2 stroke lean burn (2SLB) stationary RICE with a site rating of more than 500 brake HP located at a major source of HAP emissions; (ii) Existing spark ignition 4 stroke lean burn (4SLB... emissions; (4) A new or reconstructed spark ignition 4 stroke rich burn (4SRB) stationary RICE with a site...

  3. 75 FR 9647 - National Emission Standards for Hazardous Air Pollutants for Reciprocating Internal Combustion...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-03

    ...EPA is promulgating national emission standards for hazardous air pollutants for existing stationary compression ignition reciprocating internal combustion engines that either are located at area sources of hazardous air pollutant emissions or that have a site rating of less than or equal to 500 brake horsepower and are located at major sources of hazardous air pollutant emissions. In addition, EPA is promulgating national emission standards for hazardous air pollutants for existing non-emergency stationary compression ignition engines greater than 500 brake horsepower that are located at major sources of hazardous air pollutant emissions. Finally, EPA is revising the provisions related to startup, shutdown, and malfunction for the engines that were regulated previously by these national emission standards for hazardous air pollutants.

  4. Testing of a spacecraft model in a combined environment simulator

    NASA Technical Reports Server (NTRS)

    Staskus, J. V.; Roche, J. C.

    1981-01-01

    A scale model of a satellite was tested in a large vacuum facility under electron bombardment and vacuum ultraviolet radiation to investigate the charging of dielectric materials on curved surfaces. The model was tested both stationary and rotating relative to the electron sources as well as grounded through one megohm and floating relative to the chamber. Surface potential measurements are presented and compared with the predictions of computer modelling of the stationary tests. Discharge activity observed during the stationary tests is discussed and signals from sensing devices located inside and outside of the model are presented.

  5. Monitoring by Control Technique - Activated Carbon Adsorber

    EPA Pesticide Factsheets

    Stationary source emissions monitoring is required to demonstrate that a source is meeting the requirements in Federal or state rules. This page is about Activated Carbon Adsorber control techniques used to reduce pollutant emissions.

  6. Monitoring by Control Technique - Electrified Filter Bed

    EPA Pesticide Factsheets

    Stationary source emissions monitoring is required to demonstrate that a source is meeting the requirements in Federal or state rules. This page is about electrified filter bed control techniques used to reduce pollutant emissions.

  7. 40 CFR 49.130 - Rule for limiting sulfur in fuels.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... fuels that are burned at stationary sources within the Indian reservation to control emissions of sulfur..., gaseous fuel, marine vessel, mobile sources, motor vehicle, nonroad engine, nonroad vehicle, owner or...

  8. 40 CFR 49.130 - Rule for limiting sulfur in fuels.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... burned at stationary sources within the Indian reservation to control emissions of sulfur dioxide (SO2..., gaseous fuel, marine vessel, mobile sources, motor vehicle, nonroad engine, nonroad vehicle, owner or...

  9. Solid state lighting devices and methods with rotary cooling structures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koplow, Jeffrey P.

    Solid state lighting devices and methods for heat dissipation with rotary cooling structures are described. An example solid state lighting device includes a solid state light source, a rotating heat transfer structure in thermal contact with the solid state light source, and a mounting assembly having a stationary portion. The mounting assembly may be rotatably coupled to the heat transfer structure such that at least a portion of the mounting assembly remains stationary while the heat transfer structure is rotating. Examples of methods for dissipating heat from electrical devices, such as solid state lighting sources are also described. Heat dissipationmore » methods may include providing electrical power to a solid state light source mounted to and in thermal contact with a heat transfer structure, and rotating the heat transfer structure through a surrounding medium.« less

  10. Explanation of temporal clustering of tsunami sources using the epidemic-type aftershock sequence model

    USGS Publications Warehouse

    Geist, Eric L.

    2014-01-01

    Temporal clustering of tsunami sources is examined in terms of a branching process model. It previously was observed that there are more short interevent times between consecutive tsunami sources than expected from a stationary Poisson process. The epidemic‐type aftershock sequence (ETAS) branching process model is fitted to tsunami catalog events, using the earthquake magnitude of the causative event from the Centennial and Global Centroid Moment Tensor (CMT) catalogs and tsunami sizes above a completeness level as a mark to indicate that a tsunami was generated. The ETAS parameters are estimated using the maximum‐likelihood method. The interevent distribution associated with the ETAS model provides a better fit to the data than the Poisson model or other temporal clustering models. When tsunamigenic conditions (magnitude threshold, submarine location, dip‐slip mechanism) are applied to the Global CMT catalog, ETAS parameters are obtained that are consistent with those estimated from the tsunami catalog. In particular, the dip‐slip condition appears to result in a near zero magnitude effect for triggered tsunami sources. The overall consistency between results from the tsunami catalog and that from the earthquake catalog under tsunamigenic conditions indicates that ETAS models based on seismicity can provide the structure for understanding patterns of tsunami source occurrence. The fractional rate of triggered tsunami sources on a global basis is approximately 14%.

  11. Optical remote sensing to quantify fugitive particulate mass emissions from stationary short-term and mobile continuous sources: part II. Field applications.

    PubMed

    Du, Ke; Yuen, Wangki; Wang, Wei; Rood, Mark J; Varma, Ravi M; Hashmonay, Ram A; Kim, Byung J; Kemme, Michael R

    2011-01-15

    Quantification of emissions of fugitive particulate matter (PM) into the atmosphere from military training operations is of interest by the United States Department of Defense. A new range-resolved optical remote sensing (ORS) method was developed to quantify fugitive PM emissions from puff sources (i.e., artillery back blasts), ground-level mobile sources (i.e., movement of tracked vehicles), and elevated mobile sources (i.e., airborne helicopters) in desert areas that are prone to generating fugitive dust plumes. Real-time, in situ mass concentration profiles for PM mass with particle diameters <10 μm (PM(10)) and <2.5 μm (PM(2.5)) were obtained across the dust plumes that were generated by these activities with this new method. Back blasts caused during artillery firing were characterized as a stationary short-term puff source whose plumes typically dispersed to <10 m above the ground with durations of 10-30 s. Fugitive PM emissions caused by artillery back blasts were related to the zone charge and ranged from 51 to 463 g PM/firing for PM(10) and 9 to 176 g PM/firing for PM(2.5). Movement of tracked vehicles and flying helicopters was characterized as mobile continuous sources whose plumes typically dispersed 30-50 m above the ground with durations of 100-200 s. Fugitive PM emissions caused by moving tracked vehicles ranged from 8.3 to 72.5 kg PM/km for PM(10) and 1.1 to 17.2 kg PM/km for PM(2.5), and there was no obvious correlation between PM emission and vehicle speed. The emission factor for the helicopter flying at 3 m above the ground ranged from 14.5 to 114.1 kg PM/km for PM(10) and 5.0 to 39.5 kg PM/km for PM(2.5), depending on the velocity of the helicopter and type of soil it flies over. Fugitive PM emissions by an airborne helicopter were correlated with helicopter speed for a particular soil type. The results from this range-resolved ORS method were also compared with the data obtained with another path-integrated ORS method and a Flux Tower method.

  12. DETERMINANTS OF HUMAN EXPOSURES TO AIR TOXICS AND ASSOCIATED HEALTH EFFECTS

    EPA Science Inventory

    Individuals are exposed to wide variety of air toxics in various indoor and outdoor microenvironments during the course of their daily activities. Sources of emissions include a wide variety of indoor and outdoor sources, including stationary and mobile sources, building material...

  13. What, Where, When, Who and How: Accounting for Biogenic CO2 Emissions Fluxes

    NASA Astrophysics Data System (ADS)

    Ohrel, S. B.

    2013-12-01

    The world is facing a future with a changing climate as well as increasing energy needs. Many countries, including the United States, are therefore considering an increased role of biomass in domestic energy portfolios. Accounting for emissions related to biomass production and use for energy is a complex issue: determining the extent to which biomass utilization can contribute to meeting energy needs while not contributing additional GHG emissions to the atmosphere necessitates further research. Such analysis becomes more challenging when evaluating biogenic feedstocks with long rotations (i.e., woody biomass). Detailed analysis and new accounting methods are needed in order to better assess and understand the potential implications of increased bioenergy utilization in the United States energy portfolio. In response to the EPA's 2011 Draft Accounting Framework for Biogenic CO2 Emissions from Stationary Sources, the Biogenic Carbon Emissions Panel (BCE Panel) appointed by the Science Advisory Board (2013) found that 'Carbon neutrality cannot be assumed for all biomass energy a priori. There are circumstances in which biomass is grown, harvested and combusted in a carbon neutral fashion but carbon neutrality is not an appropriate a priori assumption; it is a conclusion that should be reached only after considering a particular feedstock's production and consumption cycle. There is considerable heterogeneity in feedstock types, sources and production methods and thus net biogenic carbon emissions will vary considerably.' In that light, this study discusses the current policy discussion on biogenic feedstock use for energy in the United States. It then evaluates the question: how can we account for stationary source biogenic CO2 emissions while considering the biological cycling of carbon on the biogenic feedstock production landscape? The analysis discusses current biogenic feedstock usage in the U.S. and potential future impacts of increased biogenic feedstock production on U.S. land use, supply of non-energy commodities (e.g., timber, food crops), and related GHG emission fluxes. This paper first assesses current methods for accounting for land use sector biogenic CO2 emissions (i.e., IPCC approach). Based on the finding that no current methods exist for linking stationary source emissions with the land producing biogenic feedstocks, a unique method is needed that takes into consideration the biological cycling of carbon when accounting for biogenic emissions from energy use. The paper then describes the key technical and scientific considerations that should be taken in account, such as: the implications of baseline chosen; the important roles of temporal and spatial scales; emissions fluxes during feedstock production as well as transportation, storage and processing; the role of land use management and change, etc. It also discusses how these considerations can vary depending on feedstock type (e.g., long versus short rotation).

  14. The effect of aerosols on northern hemisphere wintertime stationary waves

    NASA Astrophysics Data System (ADS)

    Lewinschal, Anna; Ekman, Annica M. L.

    2010-05-01

    Aerosol particles have a considerable impact on the energy budget of the atmosphere because of their ability to scatter and absorb incoming solar radiation. Since the beginning of the industrialisation a large increase has been seen mainly in the concentrations of sulphate and black carbon as a result of combustion of fossil fuel and biomass burning. Aerosol particles have a relatively short residence time in the atmosphere why the aerosol concentration shows a large variation spatially as well as in time where high concentrations are found close to emission sources. This leads to a highly varying radiative forcing pattern which modifies temperature gradients which in turn can alter the pressure distribution and lead to changes in the circulation in the atmosphere. In this study, the effect on the wintertime planetary scale waves on the northern hemisphere is specifically considered together with the regional climate impact due to changes in the stationary waves. To investigate the effect of aerosols on the circulation a global general circulation model based on the ECMWF operational forecast model is used (EC-Earth). The aerosol description in EC-Earth consists of prescribed monthly mean mass concentration fields of five different types of aerosols: sulphate, black carbon, organic carbon, dust and sea salt. Only the direct radiative effect is considered and the different aerosol types are treated as external mixtures. Changes in the stationary wave pattern are determined by comparing model simulations using present-day and pre-industrial concentrations of aerosol particles. Since the planetary scale waves largely influence the storm tracks and are an important part of the meridional heat transport, changes in the wave pattern may have substantial impact on the climate globally and locally. By looking at changes in the model simulations globally it can be found that the aerosol radiative forcing has the potential to change the stationary wave pattern. Furthermore, it shows that regional changes in the climate occur also where the radiative forcing from aerosol particles is not particularly strong, which would indicate that the large scale dynamical response to aerosol forcing can induce changes in temperature, precipitation and wind patterns outside the region where the forcing is initially located.

  15. Comparison of GC stationary phases for the separation of fatty acid methyl esters in biodiesel fuels.

    PubMed

    Goding, Julian C; Ragon, Dorisanne Y; O'Connor, Jack B; Boehm, Sarah J; Hupp, Amber M

    2013-07-01

    The fatty acid methyl ester (FAME) content of biodiesel fuels has traditionally been determined using gas chromatography with a polar stationary phase. In this study, a direct comparison of the separation of FAMEs present in various biodiesel samples on three polar stationary phases and one moderately polar stationary phase (with comparable column dimensions) was performed. Retention on each column was based on solubility in and polarity of the phase. Quantitative metrics describing the resolution of important FAME pairs indicate high resolution on all polar columns, yet the best resolution, particularly of geometric isomers, is achieved on the cyanopropyl column. In addition, the separation of four C18 monounsaturated isomers was optimized and the elution order determined on each column. FAME composition of various biodiesel fuel types was determined on each column to illustrate (1) chemical differences in biodiesels produced from different feedstocks and (2) chemical similarities in biodiesels of the same feedstock type produced in different locations and harvest seasons.

  16. Relating Structure and Function in the Human Brain: Relative Contributions of Anatomy, Stationary Dynamics, and Non-stationarities

    PubMed Central

    Messé, Arnaud; Rudrauf, David; Benali, Habib; Marrelec, Guillaume

    2014-01-01

    Investigating the relationship between brain structure and function is a central endeavor for neuroscience research. Yet, the mechanisms shaping this relationship largely remain to be elucidated and are highly debated. In particular, the existence and relative contributions of anatomical constraints and dynamical physiological mechanisms of different types remain to be established. We addressed this issue by systematically comparing functional connectivity (FC) from resting-state functional magnetic resonance imaging data with simulations from increasingly complex computational models, and by manipulating anatomical connectivity obtained from fiber tractography based on diffusion-weighted imaging. We hypothesized that FC reflects the interplay of at least three types of components: (i) a backbone of anatomical connectivity, (ii) a stationary dynamical regime directly driven by the underlying anatomy, and (iii) other stationary and non-stationary dynamics not directly related to the anatomy. We showed that anatomical connectivity alone accounts for up to 15% of FC variance; that there is a stationary regime accounting for up to an additional 20% of variance and that this regime can be associated to a stationary FC; that a simple stationary model of FC better explains FC than more complex models; and that there is a large remaining variance (around 65%), which must contain the non-stationarities of FC evidenced in the literature. We also show that homotopic connections across cerebral hemispheres, which are typically improperly estimated, play a strong role in shaping all aspects of FC, notably indirect connections and the topographic organization of brain networks. PMID:24651524

  17. Changes of trehalose content and expression of relative genes during the bioethanol fermentation by Saccharomyces cerevisiae.

    PubMed

    Yi, Chenfeng; Wang, Fenglian; Dong, Shijun; Li, Hao

    2016-10-01

    Traditionally, trehalose is considered as a protectant to improve the ethanol tolerance of Saccharomyces cerevisiae. In this study, to clarify the changes and roles of trehalose during the bioethanol fermentation, trehalose content and expression of related genes at lag, exponential, and stationary phases (i.e., 2, 8, and 16 h of batch fermentation process) were determined. Although yeast cells at exponential and stationary phase had higher trehalose content than cells at lag phase (P < 0.01), there was no significant difference in trehalose content between exponential and stationary phases (P > 0.05). Moreover, expression of the trehalose degradation-related genes NTH1 and NTH2 decreased at exponential phase in comparison with that at lag phase; compared with cells at lag phase, cells at stationary phase had higher expression of TPS1, ATH1, NTH1, and NTH2 but lower expression of TPS2. During the lag-exponential phase transition, downregulation of NTH1 and NTH2 promoted accumulation of trehalose, and to some extent, trehalose might confer ethanol tolerance to S. cerevisiae before stationary phase. During the exponential-stationary phase transition, upregulation of TPS1 contributed to accumulation of trehalose, and Tps1 protein might be indispensable in yeast cells to withstand ethanol stress at the stationary phase. Moreover, trehalose would be degraded to supply carbon source at stationary phase.

  18. 40 CFR 60.4340 - How do I demonstrate continuous compliance for NOX if I do not use water or steam injection?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... compliance for NOX if I do not use water or steam injection? 60.4340 Section 60.4340 Protection of... NEW STATIONARY SOURCES Standards of Performance for Stationary Combustion Turbines Monitoring § 60.4340 How do I demonstrate continuous compliance for NOX if I do not use water or steam injection? (a...

  19. 40 CFR 60.4340 - How do I demonstrate continuous compliance for NOX if I do not use water or steam injection?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... compliance for NOX if I do not use water or steam injection? 60.4340 Section 60.4340 Protection of... NEW STATIONARY SOURCES Standards of Performance for Stationary Combustion Turbines Monitoring § 60.4340 How do I demonstrate continuous compliance for NOX if I do not use water or steam injection? (a...

  20. 40 CFR 60.4340 - How do I demonstrate continuous compliance for NOX if I do not use water or steam injection?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... compliance for NOX if I do not use water or steam injection? 60.4340 Section 60.4340 Protection of... NEW STATIONARY SOURCES Standards of Performance for Stationary Combustion Turbines Monitoring § 60.4340 How do I demonstrate continuous compliance for NOX if I do not use water or steam injection? (a...

  1. 40 CFR 60.4340 - How do I demonstrate continuous compliance for NOX if I do not use water or steam injection?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... compliance for NOX if I do not use water or steam injection? 60.4340 Section 60.4340 Protection of... NEW STATIONARY SOURCES Standards of Performance for Stationary Combustion Turbines Monitoring § 60.4340 How do I demonstrate continuous compliance for NOX if I do not use water or steam injection? (a...

  2. 40 CFR 60.4340 - How do I demonstrate continuous compliance for NOX if I do not use water or steam injection?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... compliance for NOX if I do not use water or steam injection? 60.4340 Section 60.4340 Protection of... NEW STATIONARY SOURCES Standards of Performance for Stationary Combustion Turbines Monitoring § 60.4340 How do I demonstrate continuous compliance for NOX if I do not use water or steam injection? (a...

  3. The boundary integral theory for slow and rapid curved solid/liquid interfaces propagating into binary systems

    NASA Astrophysics Data System (ADS)

    Galenko, Peter K.; Alexandrov, Dmitri V.; Titova, Ekaterina A.

    2018-01-01

    The boundary integral method for propagating solid/liquid interfaces is detailed with allowance for the thermo-solutal Stefan-type models. Two types of mass transfer mechanisms corresponding to the local equilibrium (parabolic-type equation) and local non-equilibrium (hyperbolic-type equation) solidification conditions are considered. A unified integro-differential equation for the curved interface is derived. This equation contains the steady-state conditions of solidification as a special case. The boundary integral analysis demonstrates how to derive the quasi-stationary Ivantsov and Horvay-Cahn solutions that, respectively, define the paraboloidal and elliptical crystal shapes. In the limit of highest Péclet numbers, these quasi-stationary solutions describe the shape of the area around the dendritic tip in the form of a smooth sphere in the isotropic case and a deformed sphere along the directions of anisotropy strength in the anisotropic case. A thermo-solutal selection criterion of the quasi-stationary growth mode of dendrites which includes arbitrary Péclet numbers is obtained. To demonstrate the selection of patterns, computational modelling of the quasi-stationary growth of crystals in a binary mixture is carried out. The modelling makes it possible to obtain selected structures in the form of dendritic, fractal or planar crystals. This article is part of the theme issue `From atomistic interfaces to dendritic patterns'.

  4. Monitoring by Control Technique - Wet Scrubber For Particulate Matter

    EPA Pesticide Factsheets

    Stationary source emissions monitoring is required to demonstrate that a source is meeting the requirements in Federal or state rules. This page is about Wet Scrubber For Particulate Matter controls used to reduce pollutant emissions.

  5. 40 CFR 63.4881 - Am I subject to this subpart?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... application of coatings to a substrate using, for example, spray guns or dip tanks. (2) Metal furniture means... source or group of stationary sources located within a contiguous area and under common control that...

  6. Monitoring Information By Industry - Printing and Publishing

    EPA Pesticide Factsheets

    Stationary source emissions monitoring is required to demonstrate that a source is meeting the requirements in Federal or state rules. This page is about control techniques used to reduce pollutant emissions in the printing and publishing industry.

  7. Stationary states of extended nonlinear Schrödinger equation with a source

    NASA Astrophysics Data System (ADS)

    Borich, M. A.; Smagin, V. V.; Tankeev, A. P.

    2007-02-01

    Structure of nonlinear stationary states of the extended nonlinear Schrödinger equation (ENSE) with a source has been analyzed with allowance for both third-order and nonlinearity dispersion. A new class of particular solutions (solitary waves) of the ENSe has been obtained. The scenario of the destruction of these states under the effect of an external perturbation has been investigated analytically and numerically. The results obtained can be used to interpret experimental data on the weakly nonlinear dynamics of the magnetostatic envelope in heterophase ferromagnet-insulator-metal, metal-insulator-ferromagnet-insulator-metal, and other similar structures and upon the simulation of nonlinear processes in optical systems.

  8. Angular acceptance analysis of an infrared focal plane array with a built-in stationary Fourier transform spectrometer.

    PubMed

    Gillard, Frédéric; Ferrec, Yann; Guérineau, Nicolas; Rommeluère, Sylvain; Taboury, Jean; Chavel, Pierre

    2012-06-01

    Stationary Fourier transform spectrometry is an interesting concept for building reliable field or embedded spectroradiometers, especially for the mid- and far- IR. Here, a very compact configuration of a cryogenic stationary Fourier transform IR (FTIR) spectrometer is investigated, where the interferometer is directly integrated in the focal plane array (FPA). We present a theoretical analysis to explain and describe the fringe formation inside the FTIR-FPA structure when illuminated by an extended source positioned at a finite distance from the detection plane. The results are then exploited to propose a simple front lens design compatible with a handheld package.

  9. Sewage Sludge Incinerators: Final Standards of Performance for New Stationary Sources and Emission Guidelines for Existing Sources Final Rule Fact Sheets

    EPA Pesticide Factsheets

    This page contains a February 2011 fact sheet with information regarding the final NSPS and Emission Guidelines for Existing Sources for Sewage Sludge Incinerators (SSI). This document provides a summary of the information for these regulations.

  10. Supplement a to compilation of air pollutant emission factors. Volume 1. Stationary point and area sources. Fifth edition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1996-02-01

    This Supplement to AP-42 addresses pollutant-generating activity from Bituminous and Subbituminous Coal Combustion; Anthracite Coal Combustion; Fuel Oil Combustion; Natural Gas Combustion; Wood Waste Combustion in Boilers; Lignite Combustion; Waste Oil Combustion: Stationary Gas Turbines for Electricity Generation; Heavy-duty Natural Gas-fired Pipeline Compressor Engines; Large Stationary Diesel and all Stationary Dual-fuel engines; Natural Gas Processing; Organic Liquid Storage Tanks; Meat Smokehouses; Meat Rendering Plants; Canned Fruits and Vegetables; Dehydrated Fruits and Vegetables; Pickles, Sauces and Salad Dressing; Grain Elevators and Processes; Cereal Breakfast Foods; Pasta Manufacturing; Vegetable Oil Processing; Wines and Brandy; Coffee Roasting; Charcoal; Coal Cleaning; Frit Manufacturing; Sandmore » and Gravel Processing; Diatomite Processing; Talc Processing; Vermiculite Processing; paved Roads; and Unpaved Roads. Also included is information on Generalized Particle Size Distributions.« less

  11. Joint simulation of stationary grade and non-stationary rock type for quantifying geological uncertainty in a copper deposit

    NASA Astrophysics Data System (ADS)

    Maleki, Mohammad; Emery, Xavier

    2017-12-01

    In mineral resources evaluation, the joint simulation of a quantitative variable, such as a metal grade, and a categorical variable, such as a rock type, is challenging when one wants to reproduce spatial trends of the rock type domains, a feature that makes a stationarity assumption questionable. To address this problem, this work presents methodological and practical proposals for jointly simulating a grade and a rock type, when the former is represented by the transform of a stationary Gaussian random field and the latter is obtained by truncating an intrinsic random field of order k with Gaussian generalized increments. The proposals concern both the inference of the model parameters and the construction of realizations conditioned to existing data. The main difficulty is the identification of the spatial correlation structure, for which a semi-automated algorithm is designed, based on a least squares fitting of the data-to-data indicator covariances and grade-indicator cross-covariances. The proposed models and algorithms are applied to jointly simulate the copper grade and the rock type in a Chilean porphyry copper deposit. The results show their ability to reproduce the gradual transitions of the grade when crossing a rock type boundary, as well as the spatial zonation of the rock type.

  12. Technical Support Document for Title V Permitting of Printing Facilities

    EPA Pesticide Factsheets

    Stationary source emissions monitoring is required to demonstrate that a source is meeting the requirements in Federal or state rules, including Title V. This document provides the technical support for compliance in the printing and publishing industry.

  13. Stationary Source Permit Applicability of Emissions from Automobile Roll-Off Testing

    EPA Pesticide Factsheets

    This document may be of assistance in applying the New Source Review (NSR) air permitting regulations including the Prevention of Significant Deterioration (PSD) requirements. This document is part of the NSR Policy and Guidance Database.

  14. FIRST ORDER ESTIMATES OF ENERGY REQUIREMENTS FOR POLLUTION CONTROL

    EPA Science Inventory

    This report presents estimates of the energy demand attributable to environmental control of pollution from 'stationary point sources.' This class of pollution source includes powerplants, factories, refineries, municipal waste water treatment plants, etc., but excludes 'mobile s...

  15. 40 CFR 60.1030 - Can the Administrator delegate authority to enforce these Federal new source performance...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Small Municipal Waste Combustion Units for Which Construction is Commenced After August 30, 1999 or for Which Modification or...

  16. 40 CFR 60.1030 - Can the Administrator delegate authority to enforce these Federal new source performance...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Small Municipal Waste Combustion Units for Which Construction is Commenced After August 30, 1999 or for Which Modification or...

  17. 40 CFR 60.1030 - Can the Administrator delegate authority to enforce these Federal new source performance...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Small Municipal Waste Combustion Units for Which Construction is Commenced After August 30, 1999 or for Which Modification or...

  18. 40 CFR Table 2c to Subpart Zzzz of... - Requirements for Existing Compression Ignition Stationary RICE Located at a Major Source of HAP...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... stationary CI RICE 1 a. Change oil and filter every 500 hours of operation or annually, whichever comes first.2 b. Inspect air cleaner every 1,000 hours of operation or annually, whichever comes first, and... comes first, and replace as necessary.3 Minimize the engine's time spent at idle and minimize the engine...

  19. 40 CFR Table 2c to Subpart Zzzz of... - Requirements for Existing Compression Ignition Stationary RICE Located at a Major Source of HAP...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... stationary CI RICE 1 a. Change oil and filter every 500 hours of operation or annually, whichever comes first.2 b. Inspect air cleaner every 1,000 hours of operation or annually, whichever comes first, and... comes first, and replace as necessary.3 Minimize the engine's time spent at idle and minimize the engine...

  20. 40 CFR Table 2c to Subpart Zzzz of... - Requirements for Existing Compression Ignition Stationary RICE Located at a Major Source of HAP...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... stationary CI RICE. 1 a. Change oil and filter every 500 hours of operation or annually, whichever comes first; 2 b. Inspect air cleaner every 1,000 hours of operation or annually, whichever comes first; c. Inspect all hoses and belts every 500 hours of operation or annually, whichever comes first, and replace...

  1. 40 CFR Table 4 to Subpart Jjjj of... - Applicability of Mobile Source Provisions for Manufacturers Participating in the Voluntary...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... SI ICE to Emission Standards in Table 1 of Subpart JJJJ 4 Table 4 to Subpart JJJJ of Part 60... Stationary SI ICE to Emission Standards in Table 1 of Subpart JJJJ [As stated in § 60.4247, you must comply... voluntary certification program and certifying stationary SI ICE to emission standards in Table 1 of subpart...

  2. 40 CFR Table 4 to Subpart Jjjj of... - Applicability of Mobile Source Provisions for Manufacturers Participating in the Voluntary...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... SI ICE to Emission Standards in Table 1 of Subpart JJJJ 4 Table 4 to Subpart JJJJ of Part 60... Stationary SI ICE to Emission Standards in Table 1 of Subpart JJJJ [As stated in § 60.4247, you must comply... voluntary certification program and certifying stationary SI ICE to emission standards in Table 1 of subpart...

  3. 40 CFR Table 4 to Subpart Jjjj of... - Applicability of Mobile Source Provisions for Manufacturers Participating in the Voluntary...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... SI ICE to Emission Standards in Table 1 of Subpart JJJJ 4 Table 4 to Subpart JJJJ of Part 60... Stationary SI ICE to Emission Standards in Table 1 of Subpart JJJJ [As stated in § 60.4247, you must comply... voluntary certification program and certifying stationary SI ICE to emission standards in Table 1 of subpart...

  4. 40 CFR Table 4 to Subpart Jjjj of... - Applicability of Mobile Source Provisions for Manufacturers Participating in the Voluntary...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... SI ICE to Emission Standards in Table 1 of Subpart JJJJ 4 Table 4 to Subpart JJJJ of Part 60... Stationary SI ICE to Emission Standards in Table 1 of Subpart JJJJ [As stated in § 60.4247, you must comply... voluntary certification program and certifying stationary SI ICE to emission standards in Table 1 of subpart...

  5. 40 CFR Table 4 to Subpart Jjjj of... - Applicability of Mobile Source Provisions for Manufacturers Participating in the Voluntary...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... SI ICE to Emission Standards in Table 1 of Subpart JJJJ 4 Table 4 to Subpart JJJJ of Part 60... Stationary SI ICE to Emission Standards in Table 1 of Subpart JJJJ [As stated in § 60.4247, you must comply... voluntary certification program and certifying stationary SI ICE to emission standards in Table 1 of subpart...

  6. Stability of Bifurcating Stationary Solutions of the Artificial Compressible System

    NASA Astrophysics Data System (ADS)

    Teramoto, Yuka

    2018-02-01

    The artificial compressible system gives a compressible approximation of the incompressible Navier-Stokes system. The latter system is obtained from the former one in the zero limit of the artificial Mach number ɛ which is a singular limit. The sets of stationary solutions of both systems coincide with each other. It is known that if a stationary solution of the incompressible system is asymptotically stable and the velocity field of the stationary solution satisfies an energy-type stability criterion, then it is also stable as a solution of the artificial compressible one for sufficiently small ɛ . In general, the range of ɛ shrinks when the spectrum of the linearized operator for the incompressible system approaches to the imaginary axis. This can happen when a stationary bifurcation occurs. It is proved that when a stationary bifurcation from a simple eigenvalue occurs, the range of ɛ can be taken uniformly near the bifurcation point to conclude the stability of the bifurcating solution as a solution of the artificial compressible system.

  7. A beam optics study of a modular multi-source X-ray tube for novel computed tomography applications

    NASA Astrophysics Data System (ADS)

    Walker, Brandon J.; Radtke, Jeff; Chen, Guang-Hong; Eliceiri, Kevin W.; Mackie, Thomas R.

    2017-10-01

    A modular implementation of a scanning multi-source X-ray tube is designed for the increasing number of multi-source imaging applications in computed tomography (CT). An electron beam array coupled with an oscillating magnetic deflector is proposed as a means for producing an X-ray focal spot at any position along a line. The preliminary multi-source model includes three thermionic electron guns that are deflected in tandem by a slowly varying magnetic field and pulsed according to a scanning sequence that is dependent on the intended imaging application. Particle tracking simulations with particle dynamics analysis software demonstrate that three 100 keV electron beams are laterally swept a combined distance of 15 cm over a stationary target with an oscillating magnetic field of 102 G perpendicular to the beam axis. Beam modulation is accomplished using 25 μs pulse widths to a grid electrode with a reverse gate bias of -500 V and an extraction voltage of +1000 V. Projected focal spot diameters are approximately 1 mm for 138 mA electron beams and the stationary target stays within thermal limits for the 14 kW module. This concept could be used as a research platform for investigating high-speed stationary CT scanners, for lowering dose with virtual fan beam formation, for reducing scatter radiation in cone-beam CT, or for other industrial applications.

  8. Physical and non-physical energy in scattered wave source-receiver interferometry.

    PubMed

    Meles, Giovanni Angelo; Curtis, Andrew

    2013-06-01

    Source-receiver interferometry allows Green's functions between sources and receivers to be estimated by means of convolution and cross-correlation of other wavefields. Source-receiver interferometry has been observed to work surprisingly well in practical applications when theoretical requirements (e.g., complete enclosing boundaries of other sources and receivers) are contravened: this paper contributes to explain why this may be true. Commonly used inter-receiver interferometry requires wavefields to be generated around specific stationary points in space which are controlled purely by medium heterogeneity and receiver locations. By contrast, application of source-receiver interferometry constructs at least kinematic information about physically scattered waves between a source and a receiver by cross-convolution of scattered waves propagating from and to any points on the boundary. This reduces the ambiguity in interpreting wavefields generated using source-receiver interferometry with only partial boundaries (as is standard in practical applications), as it allows spurious or non-physical energy in the constructed Green's function to be identified and ignored. Further, source-receiver interferometry (which includes a step of inter-receiver interferometry) turns all types of non-physical or spurious energy deriving from inter-receiver interferometry into what appears to be physical energy. This explains in part why source-receiver interferometry may perform relatively well compared to inter-receiver interferometry when constructing scattered wavefields.

  9. Transiting Planet Search in the Kepler Pipeline

    NASA Technical Reports Server (NTRS)

    Jenkins, Jon M.; Chandrasekaran, Hema; McCauliff, Sean D.; Caldwell, Douglas A.; Tenebaum, Peter; Li, Jie; Klaus, Todd C.; Cote, Mile T.; Middour, Christopher

    2010-01-01

    The Kepler Mission simultaneously measures the brightness of more than 160,000 stars every 29.4 minutes over a 3.5-year mission to search for transiting planets. Detecting transits is a signal-detection problem where the signal of interest is a periodic pulse train and the predominant noise source is non-white, non-stationary (1/f) type process of stellar variability. Many stars also exhibit coherent or quasi-coherent oscillations. The detection algorithm first identifies and removes strong oscillations followed by an adaptive, wavelet-based matched filter. We discuss how we obtain super-resolution detection statistics and the effectiveness of the algorithm for Kepler flight data.

  10. Adsorption of water from aqueous acetonitrile on silica-based stationary phases in aqueous normal-phase liquid chromatography.

    PubMed

    Soukup, Jan; Jandera, Pavel

    2014-12-29

    Excess adsorption of water from aqueous acetonitrile mobile phases was investigated on 16 stationary phases using the frontal analysis method and coulometric Karl-Fischer titration. The stationary phases include silica gel and silica-bonded phases with different polarities, octadecyl and cholesterol, phenyl, nitrile, pentafluorophenylpropyl, diol and zwitterionic sulfobetaine and phosphorylcholine ligands bonded on silica, hybrid organic-silica and hydrosilated matrices. Both fully porous and core-shell column types were included. Preferential uptake of water by the columns can be described by Langmuir isotherms. Even though a diffuse rather than a compact adsorbed discrete layer of water on the adsorbent surface can be formed because of the unlimited miscibility of water with acetonitrile, for convenience, the preferentially adsorbed water was expressed in terms of a hypothetical monomolecular water layer equivalent in the inner pores. The uptake of water strongly depends on the polarity and type of the column. Less than one monomolecular water layer equivalent was adsorbed on moderate polar silica hydride-based stationary phases, Ascentis Express F5 and Ascentis Express CN column at the saturation capacity, while on more polar stationary phases, several water layer equivalents were up-taken from the mobile phase. The strongest affinity to water was observed on the ZIC cHILIC stationary phases, where more than nine water layer equivalents were adsorbed onto its surface at its saturation capacity. Columns with bonded hydroxyl and diol ligands show stronger water adsorption in comparison to bare silica. Columns based on hydrosilated silica generally show significantly decreased water uptake in comparison to stationary phases bonded on ordinary silica. Significant correlations were found between the water uptake and the separation selectivity for compounds with strong polarity differences. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. The transformed-stationary approach: a generic and simplified methodology for non-stationary extreme value analysis

    NASA Astrophysics Data System (ADS)

    Mentaschi, Lorenzo; Vousdoukas, Michalis; Voukouvalas, Evangelos; Sartini, Ludovica; Feyen, Luc; Besio, Giovanni; Alfieri, Lorenzo

    2016-09-01

    Statistical approaches to study extreme events require, by definition, long time series of data. In many scientific disciplines, these series are often subject to variations at different temporal scales that affect the frequency and intensity of their extremes. Therefore, the assumption of stationarity is violated and alternative methods to conventional stationary extreme value analysis (EVA) must be adopted. Using the example of environmental variables subject to climate change, in this study we introduce the transformed-stationary (TS) methodology for non-stationary EVA. This approach consists of (i) transforming a non-stationary time series into a stationary one, to which the stationary EVA theory can be applied, and (ii) reverse transforming the result into a non-stationary extreme value distribution. As a transformation, we propose and discuss a simple time-varying normalization of the signal and show that it enables a comprehensive formulation of non-stationary generalized extreme value (GEV) and generalized Pareto distribution (GPD) models with a constant shape parameter. A validation of the methodology is carried out on time series of significant wave height, residual water level, and river discharge, which show varying degrees of long-term and seasonal variability. The results from the proposed approach are comparable with the results from (a) a stationary EVA on quasi-stationary slices of non-stationary series and (b) the established method for non-stationary EVA. However, the proposed technique comes with advantages in both cases. For example, in contrast to (a), the proposed technique uses the whole time horizon of the series for the estimation of the extremes, allowing for a more accurate estimation of large return levels. Furthermore, with respect to (b), it decouples the detection of non-stationary patterns from the fitting of the extreme value distribution. As a result, the steps of the analysis are simplified and intermediate diagnostics are possible. In particular, the transformation can be carried out by means of simple statistical techniques such as low-pass filters based on the running mean and the standard deviation, and the fitting procedure is a stationary one with a few degrees of freedom and is easy to implement and control. An open-source MATLAB toolbox has been developed to cover this methodology, which is available at https://github.com/menta78/tsEva/ (Mentaschi et al., 2016).

  12. Competitive or weak cooperative stochastic Lotka-Volterra systems conditioned on non-extinction.

    PubMed

    Cattiaux, Patrick; Méléard, Sylvie

    2010-06-01

    We are interested in the long time behavior of a two-type density-dependent biological population conditioned on non-extinction, in both cases of competition or weak cooperation between the two species. This population is described by a stochastic Lotka-Volterra system, obtained as limit of renormalized interacting birth and death processes. The weak cooperation assumption allows the system not to blow up. We study the existence and uniqueness of a quasi-stationary distribution, that is convergence to equilibrium conditioned on non-extinction. To this aim we generalize in two-dimensions spectral tools developed for one-dimensional generalized Feller diffusion processes. The existence proof of a quasi-stationary distribution is reduced to the one for a d-dimensional Kolmogorov diffusion process under a symmetry assumption. The symmetry we need is satisfied under a local balance condition relying the ecological rates. A novelty is the outlined relation between the uniqueness of the quasi-stationary distribution and the ultracontractivity of the killed semi-group. By a comparison between the killing rates for the populations of each type and the one of the global population, we show that the quasi-stationary distribution can be either supported by individuals of one (the strongest one) type or supported by individuals of the two types. We thus highlight two different long time behaviors depending on the parameters of the model: either the model exhibits an intermediary time scale for which only one type (the dominant trait) is surviving, or there is a positive probability to have coexistence of the two species.

  13. Stationary table CT dosimetry and anomalous scanner-reported values of CTDI{sub vol}

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dixon, Robert L., E-mail: rdixon@wfubmc.edu; Boone, John M.

    2014-01-15

    Purpose: Anomalous, scanner-reported values of CTDI{sub vol} for stationary phantom/table protocols (having elevated values of CTDI{sub vol} over 300% higher than the actual dose to the phantom) have been observed; which are well-beyond the typical accuracy expected of CTDI{sub vol} as a phantom dose. Recognition of these outliers as “bad data” is important to users of CT dose index tracking systems (e.g., ACR DIR), and a method for recognition and correction is provided. Methods: Rigorous methods and equations are presented which describe the dose distributions for stationary-table CT. A comparison with formulae for scanner-reported values of CTDI{sub vol} clearly identifiesmore » the source of these anomalies. Results: For the stationary table, use of the CTDI{sub 100} formula (applicable to a moving phantom only) overestimates the dose due to extra scatter and also includes an overbeaming correction, both of which are nonexistent when the phantom (or patient) is held stationary. The reported DLP remains robust for the stationary phantom. Conclusions: The CTDI-paradigm does not apply in the case of a stationary phantom and simpler nonintegral equations suffice. A method of correction of the currently reported CTDI{sub vol} using the approach-to-equilibrium formula H(a) and an overbeaming correction factor serves to scale the reported CTDI{sub vol} values to more accurate levels for stationary-table CT, as well as serving as an indicator in the detection of “bad data.”.« less

  14. California's Ozone-Reduction Strategy for Light Duty Vehicles - An Economic Assessment

    DOT National Transportation Integrated Search

    1996-01-01

    California has adopted an aggressive plan to bring the state into compliance with national ambient air quality standards. California's strategy includes strict emission standards on mobile and stationary sourcs and on area sources such as solvents, p...

  15. 75 FR 63259 - Standards of Performance for New Stationary Sources and Emission Guidelines for Existing Sources...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-14

    ... Thermal Oxidizer SBA Small Business Administration SCR Selective Catalytic Reduction SNCR Selective Non...). Finally, on June 4, 2010, EPA proposed a definition of non- hazardous solid waste (75 FR 31844) under the...

  16. EPA Air Pollution Control Cost Manual

    EPA Science Inventory

    EPA's Air Pollution Control Cost Manual provides guidance for the development of accurate and consistent costs for air pollution control devices. A long-standing document prepared by EPA, the Control Cost Manual focuses on point source and stationary area source air pollution con...

  17. 78 FR 17168 - Approval and Promulgation of Implementation Plans; Tennessee; 110(a)(1) and (2) Infrastructure...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-20

    ... and new source review (NSR).\\4\\ \\4\\ This rulemaking only addresses requirements for this element as...)(2)(E): Adequate personnel, funding, and authority. 110(a)(2)(F): Stationary source monitoring and... related to excess emissions during periods of start-up, shutdown, or malfunction at sources (SSM), that...

  18. 78 FR 70248 - Approval and Promulgation of Implementation Plans; Commonwealth of the Northern Mariana Islands...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-25

    ... source baseline date (and trigger date) under the PSD program in CNMI for sulfur dioxide, PM 10 and... for new or modified major stationary sources (``New Source Review,'' or NSR), programs for monitoring... 1975, EPA modified part 52 by incorporating specific PSD disapprovals into the applicable subpart for...

  19. First Order Estimates of Energy Requirements for Pollution Control. Interagency Energy-Environment Research and Development Program Report.

    ERIC Educational Resources Information Center

    Barker, James L.; And Others

    This U.S. Environmental Protection Agency report presents estimates of the energy demand attributable to environmental control of pollution from stationary point sources. This class of pollution source includes powerplants, factories, refineries, municipal waste water treatment plants, etc., but excludes mobile sources such as trucks, and…

  20. Other Solid Waste Incineration (OSWI) Units Standards of Performance for New Stationary Sources and Emission Guidelines for Existing Sources Fact Sheets

    EPA Pesticide Factsheets

    This page contains a November 2005, and and November 2006 fact sheet with information regarding the final and proposed NSPS and Emission Guidelines for Existing Sources for OSWI. This document provides a summary of the information for this regulation

  1. Polymer electrolyte fuel cells: Potential transportation and stationary applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gottesfeld, S.

    1993-01-01

    The application of the polymer electrolyte fuel cell (PEFC) as a primary power source in electric vehicles has received increasing attention during the last few years. This increased attention is the result of a combination of significant technical advances in this fuel cell technology and the initiation of some projects for the demonstration of a complete, PEFC-based power system a bus or in a passenger car. Such demonstration projects reflect an increase in industry's faith in the potential of this technology for transportation applications, or, at least, in the need for a detailed evaluation of this potential. Nevertheless, large scalemore » transportation applications of PEFCs require a continued concerted effort of research on catalysis, materials and components, combined with the engineering efforts addressing the complete power system. This is required to achieve a cost effective, highly performing PEFC stack and power system. A related set of technical and cost challenges arises in the context of potential applications of PEFCs for stationary power applications, although there are clearly some differences in their nature, particularly, to do with the different types of fuels to be employed for each of these applications. We describe in this contribution some recent results of work performed by the Core Research PEFC Program at Los Alamos National Laboratory, which has addressed materials, components and single cell testing of PEFCS. Also included are some recent observations and some insights regarding the potential of this fuel cell technology for stationary Power generation.« less

  2. Polymer electrolyte fuel cells: Potential transportation and stationary applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gottesfeld, S.

    1993-04-01

    The application of the polymer electrolyte fuel cell (PEFC) as a primary power source in electric vehicles has received increasing attention during the last few years. This increased attention is the result of a combination of significant technical advances in this fuel cell technology and the initiation of some projects for the demonstration of a complete, PEFC-based power system a bus or in a passenger car. Such demonstration projects reflect an increase in industry`s faith in the potential of this technology for transportation applications, or, at least, in the need for a detailed evaluation of this potential. Nevertheless, large scalemore » transportation applications of PEFCs require a continued concerted effort of research on catalysis, materials and components, combined with the engineering efforts addressing the complete power system. This is required to achieve a cost effective, highly performing PEFC stack and power system. A related set of technical and cost challenges arises in the context of potential applications of PEFCs for stationary power applications, although there are clearly some differences in their nature, particularly, to do with the different types of fuels to be employed for each of these applications. We describe in this contribution some recent results of work performed by the Core Research PEFC Program at Los Alamos National Laboratory, which has addressed materials, components and single cell testing of PEFCS. Also included are some recent observations and some insights regarding the potential of this fuel cell technology for stationary Power generation.« less

  3. Judging sound rotation when listeners and sounds rotate: Sound source localization is a multisystem process.

    PubMed

    Yost, William A; Zhong, Xuan; Najam, Anbar

    2015-11-01

    In four experiments listeners were rotated or were stationary. Sounds came from a stationary loudspeaker or rotated from loudspeaker to loudspeaker around an azimuth array. When either sounds or listeners rotate the auditory cues used for sound source localization change, but in the everyday world listeners perceive sound rotation only when sounds rotate not when listeners rotate. In the everyday world sound source locations are referenced to positions in the environment (a world-centric reference system). The auditory cues for sound source location indicate locations relative to the head (a head-centric reference system), not locations relative to the world. This paper deals with a general hypothesis that the world-centric location of sound sources requires the auditory system to have information about auditory cues used for sound source location and cues about head position. The use of visual and vestibular information in determining rotating head position in sound rotation perception was investigated. The experiments show that sound rotation perception when sources and listeners rotate was based on acoustic, visual, and, perhaps, vestibular information. The findings are consistent with the general hypotheses and suggest that sound source localization is not based just on acoustics. It is a multisystem process.

  4. Stationary Engineers Apprenticeship. Related Training Modules. 13.1-13.7 Pumps.

    ERIC Educational Resources Information Center

    Lane Community Coll., Eugene, OR.

    This learning module, one in a series of 20 related training modules for apprentice stationary engineers, deals with pumps. Addressed in the individual instructional packages included in the module are the following topics: types, classifications, and applications of pumps; pump construction; procedures for calculating pump heat and pump flow;…

  5. Stationary Engineers Apprenticeship. Related Training Modules. 15.1-15.5 Turbines.

    ERIC Educational Resources Information Center

    Lane Community Coll., Eugene, OR.

    This learning module, one in a series of 20 related training modules for apprentice stationary engineers, deals with turbines. addressed in the individual instructional packages included in the module are the following topics: types and components of steam turbines, steam turbine auxiliaries, operation and maintenance of steam turbines, and gas…

  6. Transcriptional Characterization of Salmonella TAl00 in Growth and Stationary Phase: Mutagenesis of MX in Both Types of Cells

    EPA Science Inventory

    The Salmonella (Ames) mutagenicity assay can be performed using cells that are in different growth phases. Thus, the plate-incorporation assay involves plating stationary-phase cells with the mutagen, after which the cells undergo a brief lag phase and, consequently, are exposed ...

  7. Stationary Engineers Apprenticeship. Related Training Modules. 16.1-16.5 Combustion.

    ERIC Educational Resources Information Center

    Lane Community Coll., Eugene, OR.

    This learning module, one in a series of 20 related training modules for apprentice stationary engineers, deals with combustion. Addressed in the individual instructional packages included in the module are the following topics: the combustion process, types of fuel, air and flue gases, heat transfer during combustion, and wood combustion. Each…

  8. Solar radiation on Mars: Stationary photovoltaic array

    NASA Technical Reports Server (NTRS)

    Appelbaum, J.; Sherman, I.; Landis, G. A.

    1993-01-01

    Solar energy is likely to be an important power source for surface-based operation on Mars. Photovoltaic cells offer many advantages. In this article we have presented analytical expressions and solar radiation data for stationary flat surfaces (horizontal and inclined) as a function of latitude, season and atmospheric dust load (optical depth). The diffuse component of the solar radiation on Mars can be significant, thus greatly affecting the optimal inclination angle of the photovoltaic surface.

  9. A nonreflecting upper boundary condition for anelastic nonhydrostatic mesoscale gravity-wave models

    NASA Technical Reports Server (NTRS)

    Kim, Young-Joon; Kar, Sajal K.; Arakawa, Akio

    1993-01-01

    A sponge layer is formulated to prevent spurious reflection of vertically propagating quasi-stationary gravity waves at the upper boundary of a two-dimensional numerical anelastic nonhydrostatic model. The sponge layer includes damping of both Newtonian-cooling type and Rayleigh-friction type, whose coefficients are determined in such a way that the reflectivity of wave energy at the bottom of the layer is zero. Unlike the formulations in earlier studies, our formulation includes the effects of vertical discretization, vertical mean density variation, and nonhydrostaticity. This sponge formulation is found effective in suppressing false downward reflection of waves for various types of quasi-stationary forcing.

  10. Method of filling a microchannel separation column

    DOEpatents

    Arnold, Don W.

    2002-01-01

    A method for packing a stationary phase into a small diameter fluid passageway or flow channel. Capillary action is employed to distribute a stationary phase uniformly along both the length and diameter of the flow channel. The method disclosed here: 1) eliminates the need for high pressure pumps and fittings and the safety hazards associated therewith; 2) allows the use of readily available commercial microparticles, either coated or uncoated, as the stationary phase; 3) provides for different types of particles, different particle sizes, and different particle size distributions to be packed in sequence, or simultaneously; 4) eliminates the need for plugging the flow channel prior to adding the stationary phase to retain the packing particles; and 5) many capillaries can be filled simultaneously.

  11. New Patterns of Activity in a Pair of Interacting Excitatory-Inhibitory Neural Fields

    NASA Astrophysics Data System (ADS)

    Folias, S. E.; Ermentrout, G. B.

    2011-11-01

    In this Letter, we study stationary bump solutions in a pair of interacting excitatory-inhibitory (E-I) neural fields in one dimension. We demonstrate the existence of localized bump solutions of persistent activity that can be maintained by the pair of interacting layers when a stationary bump is not supported by either layer in isolation—a scenario which may be relevant as a mechanism for the persistent activity associated with working memory in the prefrontal cortex and may explain why bumps are not seen in in vitro slice preparations. Furthermore, we describe a new type of stationary bump solution arising from a pitchfork bifurcation which produces a stationary bump in each layer with a spatial offset that increases with the bifurcation parameter.

  12. Circulation Type Classifications and their nexus to Van Bebber's storm track Vb

    NASA Astrophysics Data System (ADS)

    Hofstätter, M.; Chimani, B.

    2012-04-01

    Circulation Type Classifications (CTCs) are tools to identify repetitive and predominantly stationary patterns of the atmospheric circulation over a certain area, with the purpose to enable the recognition of specific characteristics in surface climate variables. On the other hand storm tracks can be used to identify similar types of synoptic events from a non-stationary, kinematic perspective. Such a storm track classification for Europe has been done in the late 19th century by Van Bebber (1882, 1891), from which the famous type Vb and Vc/d remained up to the present day because of to their association with major flooding events like in August 2002 in Europe. In this work a systematic tracking procedure has been developed, to determine storm track types and their characteristics especially for the Eastern Alpine Region in the period 1961-2002, using ERA40 and ERAinterim reanalysis. The focus thereby is on cyclone tracks of type V as suggested by van Bebber and congeneric types. This new catalogue is used as a reference to verify the hypothesis of a certain coherence of storm track Vb with certain circulation types (e.g. Fricke and Kaminski, 2002). Selected objective and subjective classification schemes from the COST733 action (http://cost733.met.no/, Phillip et al. 2010) are used therefore, as well as the manual classification from ZAMG (Lauscher 1972 and 1985), in which storm track Vb has been classified explicitly on a daily base since 1948. The latter scheme should prove itself as a valuable and unique data source in that issue. Results show that not less than 146 storm tracks are identified as Vb between 1961 and 2002, whereas only three events could be found from literature, pointing to big subjectivity and preconception in the issue of Vb storm tracks. The annual number of Vb storm tracks do not show any significant trend over the last 42 years, but large variations from year to year. Circulation type classification CAP27 (Cluster Analysis of Principal Components) is the best performing, fully objective scheme tested herein, showing the power to discriminate Vb events. Most of the other fully objective schemes do by far not perform as well. Largest skill in that issue can be seen from the subjective/manual CTCs, proving themselves to enhance relevant synoptic phenomena instead of emphasizing mathematic criteria in the classification. The hypothesis of Fricke and Kaminsky can definitely be supported by this work: Vb storm tracks are included in one or the other stationary circulation pattern, but to which extent depends on the specific characteristics of the CTC in question.

  13. Monitoring by Control Technique - Compliant (Low/No VOC/HAP) Inks and Coatings

    EPA Pesticide Factsheets

    Stationary source emissions monitoring is required to demonstrate that a source is meeting the requirements in Federal or state rules. This page is about Compliant (Low/No VOC/HAP) Inks and Coatings control techniques used to reduce pollutant emissions.

  14. 77 FR 37361 - National Emission Standards for Hazardous Air Pollutants for Reciprocating Internal Combustion...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-21

    ... National Emission Standards for Hazardous Air Pollutants for Reciprocating Internal Combustion Engines; New Source Performance Standards for Stationary Internal Combustion Engines AGENCY: Environmental Protection... Standards for Hazardous Air Pollutants for Reciprocating Internal Combustion Engines; New Source Performance...

  15. SOURCE SAMPLING AND ANALYSIS GUIDANCE - A METHODS DIRECTORY

    EPA Science Inventory

    Sampling and analytical methodologies are needed by EPA and industry for testing stationary sources for specific organic compounds such as those listed under the Resource Conservation and Recovery Act (RCRA) Appendix VIII and Appendix IX and the Clean Air Act of 1990. omputerized...

  16. An LUR/BME framework to estimate PM2.5 explained by on road mobile and stationary sources.

    PubMed

    Reyes, Jeanette M; Serre, Marc L

    2014-01-01

    Knowledge of particulate matter concentrations <2.5 μm in diameter (PM2.5) across the United States is limited due to sparse monitoring across space and time. Epidemiological studies need accurate exposure estimates in order to properly investigate potential morbidity and mortality. Previous works have used geostatistics and land use regression (LUR) separately to quantify exposure. This work combines both methods by incorporating a large area variability LUR model that accounts for on road mobile emissions and stationary source emissions along with data that take into account incompleteness of PM2.5 monitors into the modern geostatistical Bayesian Maximum Entropy (BME) framework to estimate PM2.5 across the United States from 1999 to 2009. A cross-validation was done to determine the improvement of the estimate due to the LUR incorporation into BME. These results were applied to known diseases to determine predicted mortality coming from total PM2.5 as well as PM2.5 explained by major contributing sources. This method showed a mean squared error reduction of over 21.89% oversimple kriging. PM2.5 explained by on road mobile emissions and stationary emissions contributed to nearly 568,090 and 306,316 deaths, respectively, across the United States from 1999 to 2007.

  17. Bioaerosol assessment in naturally ventilated historical library building with restricted personnel access.

    PubMed

    Harkawy, Aleksander; Górny, Rafał L; Ogierman, Leonard; Wlazło, Agnieszka; Ławniczek-Wałczyk, Anna; Niesler, Anna

    2011-01-01

    The aim of this study was to check the degree and identify the sources of microbial contamination of the Jasna Gora (Bright Hill) monastery library 10 years after disinfection of the incunabula collection. The registered maximum viable indoor microbial concentrations were 1,875 and 7,100 cfu/m³ for stationary and personal measurements, whereas respective total concentrations were 71,000 and 100,000 counts/m3. There was no statistically significant difference between the concentrations of viable microorganisms measured in the stationary using Andersen, GSP, and Button samplers. Moreover, GSP and Button samplers can be interchangeably applied when viable or total microbial levels are stationary or personally measured. The culturable microorganisms constituted 0.5 - 3.9% of the total microflora only. Filamentous fungi were the most prevalent outdoors, whereas Gram-positive cocci and endospore forming Gram-positive rods dominated indoors in the air and settled dust, respectively. Hence, an unrestrained infiltration of ambient air through the draughtiness of the building envelope is probably the main process responsible for indoor fungal pollution, whereas bacterial contaminants have their major sources in the indoor environment. Moreover, even a chemically cleansed library collection, having a restricted personnel access, but under the influence of ambient air, can undergo microbial contamination and becomes an important microbial emission source.

  18. 40 CFR 467.21 - Specialized definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... AND STANDARDS (CONTINUED) ALUMINUM FORMING POINT SOURCE CATEGORY Rolling With Emulsions Subcategory... emulsions subcategory shall include rolling using emulsions, roll grinding, stationary casting, homogenizing...

  19. 40 CFR 467.21 - Specialized definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... AND STANDARDS (CONTINUED) ALUMINUM FORMING POINT SOURCE CATEGORY Rolling With Emulsions Subcategory... emulsions subcategory shall include rolling using emulsions, roll grinding, stationary casting, homogenizing...

  20. 40 CFR 467.21 - Specialized definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... AND STANDARDS (CONTINUED) ALUMINUM FORMING POINT SOURCE CATEGORY Rolling With Emulsions Subcategory... emulsions subcategory shall include rolling using emulsions, roll grinding, stationary casting, homogenizing...

  1. 76 FR 22038 - Revision to the South Coast Portion of the California State Implementation Plan, CPV Sentinel...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-20

    ... California SIP. This source-specific SIP revision is known as the CPV Sentinel Energy Project AB 1318... list of those emissions credits. The Sentinel Energy Project is a source that is not authorized to... District to transfer certain emissions credits to one stationary source, the Sentinel Energy Project. The...

  2. Weakly stationary noise filtering of satellite-acquired imagery

    NASA Technical Reports Server (NTRS)

    Palgen, J. J. O.; Tamches, I.; Deutsch, E. S.

    1971-01-01

    A type of weakly stationary noise called herringbone noise was observed in satellite imagery. The characteristics of this noise are described; a model for its simulation was developed. The model is used to degrade pictorial data for comparison with similar noise degraded Nimbus data. Two filtering methods are defined and evaluated. A user's application demonstration is discussed.

  3. Modeling and Optimization of Commercial Buildings and Stationary Fuel Cell Systems (Presentation)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ainscough, C.; McLarty, D.; Sullivan, R.

    2013-10-01

    This presentation describes the Distributed Generation Building Energy Assessment Tool (DG-BEAT) developed by the National Renewable Energy Laboratory and the University of California Irvine. DG-BEAT is designed to allow stakeholders to assess the economics of installing stationary fuel cell systems in a variety of building types in the United States.

  4. 40 CFR 52.380 - Rules and regulations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... major stationary sources in attainment areas (prevention of significant deterioration). (4) Permit fees...) Conflict of interest provisions. (9) Use of 1 percent sulfur content fuel by the following residual oil burning sources, identified under § 52.370, paragraph (c)(18). (i) Northeast Utilities, HELCO Power...

  5. California State Implementation Plan; Proposed Approval of Revisions; Northern Sonoma County Air Pollution Control District; Stationary Source Permits

    EPA Pesticide Factsheets

    EPA is proposing to approve revisions to the Northern Sonoma County Air Pollution Control District (NSCAPCD) portion of the California SIP concerning NSCAPCD's PSD permitting program for new and modified sources of air pollution.

  6. 75 FR 27249 - Standards of Performance for New Stationary Sources and Emissions Guidelines for Existing Sources...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-14

    ... other health care 325411 facilities, commercial 325412 research laboratories, 562213 commercial waste... hearing is held, it will be held at EPA's Campus located at 109 T.W. Alexander Drive in Research Triangle... (E143-03), [[Page 27250

  7. REVIEW OF METHODS FOR REMOTE SENSING OF ATMOSPHERIC EMISSIONS FROM STATIONARY SOURCES

    EPA Science Inventory

    The report reviews the commercially available and developing technologies for the application of remote sensing to the measurement of source emissions. The term 'remote sensing technology', as applied in the report, means the detection or concentration measurement of trace atmosp...

  8. Budget Options

    DTIC Science & Technology

    2000-03-01

    most likely to be disen- franchised by an earlier end to the transition may be the households that are least able to afford the equipment required for...refineries, and coke ovens, to small sources, such as bakeries and dry cleaners. The vast number and diversity of stationary sources make it

  9. CONTROLLING NOX EMISSION FROM INDUSTRIAL SOURCES

    EPA Science Inventory

    A number of regulatory actions focused on reducing NOx emissions from stationary combustion sources have been taken in the United States in the last decade. These actions include the Acid Rain NOx regulations, the Ozone Transport Commission's NOx ...

  10. Status Report on Federal Regulations for New Source Performance Standards

    ERIC Educational Resources Information Center

    High, M. Dean

    1976-01-01

    This article reviews the emission standards for stationary sources and hazardous air pollutants imposed by the Environmental Protection Agency since 1970. Judicial guidelines and court cases are analyzed to anticipate future regulations. Proposed amendments to the Clean Air Act are also discussed. (MR)

  11. A Shock-Refracted Acoustic Wave Model for Screech Amplitude in Supersonic Jets

    NASA Technical Reports Server (NTRS)

    Kandula, Max

    2007-01-01

    A physical model is proposed for the estimation of the screech amplitude in underexpanded supersonic jets. The model is based on the hypothesis that the interaction of a plane acoustic wave with stationary shock waves provides amplification of the transmitted acoustic wave upon traversing the shock. Powell's discrete source model for screech incorporating a stationary array of acoustic monopoles is extended to accommodate variable source strength. The proposed model reveals that the acoustic sources are of increasing strength with downstream distance. It is shown that the screech amplitude increases with the fully expanded jet Mach number. Comparisons of predicted screech amplitude with available test data show satisfactory agreement. The effect of variable source strength on the directivity of the fundamental (first harmonic, lowest frequency mode) and the second harmonic (overtone) is found to be unimportant with regard to the principal lobe (main or major lobe) of considerable relative strength, and is appreciable only in the secondary or minor lobes (of relatively weaker strength).

  12. A Shock-Refracted Acoustic Wave Model for the Prediction of Screech Amplitude in Supersonic Jets

    NASA Technical Reports Server (NTRS)

    Kandula, Max

    2007-01-01

    A physical model is proposed for the estimation of the screech amplitude in underexpanded supersonic jets. The model is based on the hypothesis that the interaction of a plane acoustic wave with stationary shock waves provides amplification of the transmitted acoustic wave upon traversing the shock. Powell's discrete source model for screech incorporating a stationary array of acoustic monopoles is extended to accommodate variable source strength. The proposed model reveals that the acoustic sources are of increasing strength with downstream distance. It is shown that the screech amplitude increases with the fuiiy expanded jet Mach number. Comparisons of predicted screech amplitude with available test data show satisfactory agreement. The effect of variable source strength on directivity of the fundamental (first harmonic, lowest frequency mode) and the second harmonic (overtone) is found to be unimportant with regard to the principal lobe (main or major lobe) of considerable relative strength, and is appreciable only in the secondary or minor lobes (of relatively weaker strength

  13. An assessment of the retention behaviour of polycyclic aromatic hydrocarbons on reversed phase stationary phases: selectivity and retention on C18 and phenyl-type surfaces.

    PubMed

    Kayillo, Sindy; Dennis, Gary R; Shalliker, R Andrew

    2006-09-08

    In this manuscript the retention and selectivity of a set of linear and non-linear PAHs were evaluated on five different reversed-phase columns. These phases included C18 and C18 Aqua stationary phases, as well as three phenyl phases: Propyl-phenyl, Synergi polar-RP and Cosmosil 5PBB phase. Overall, the results revealed that the phenyl-type columns offered better separation performance for the linear PAHs, while the separation of the structural isomer PAHs was enhanced on the C18 columns. The Propyl-phenyl column was found to have the highest molecular-stationary phase interactions, as evidenced by the greatest rate of change in 'S' (0.71) as a function of the molecular weight in the PAH homologous series, despite having the lowest surface coverage (3% carbon load) (where S is the slope of a plot of logk versus the solvent composition). In contrast, the C18 Aqua column, having the highest surface coverage (15% carbon load) was found to have the second lowest molecular-stationary phase interactions (rate of change in S=0.61). Interestingly, the Synergi polar-RP column, which also is a phenyl stationary phase behaved more 'C18-like' than 'phenyl-like' in many of the tests undertaken. This is probably not unexpected since all five phases were reversed phase.

  14. Preparation of a silica stationary phase co-functionalized with Wulff-type phenylboronate and C12 for mixed-mode liquid chromatography.

    PubMed

    Li, Hengye; Zhang, Xuemeng; Zhang, Lin; Wang, Xiaojin; Kong, Fenying; Fan, Dahe; Li, Lei; Wang, Wei

    2017-04-15

    A silica stationary phase was designed and synthesized through the co-functionalization of silica with Wulff-type phenylboronate and C12 for mixed-mode liquid chromatography applications. The as-synthesized stationary phase was characterized by elemental analysis and Fourier Transform-InfraRed Spectroscopy (FT-IR). Retention mechanisms, including boronate affinity (BA), reversed-phase (RP) and anion-exchange (AE), were involved. Retention mechanism switching was easily realized by adjustment of the mobile phase constitution. Cis-diol compounds could be selectively captured under neutral conditions in BA mode and off-line separated in RP mode. Neutral, basic, acidic and amphiprotic compounds were chromatographed on the column in RP chromatography, while inorganic anions were chromatographed in AE chromatography to characterize the mixed-mode nature of the prepared stationary phase. In addition, the RP performance was compared with an octadecyl silica column in terms of column efficiency (N/m), asymmetry factor (A f ), retention factor (k) and resolution (Rs). The prepared stationary phase offered multiple interactions with analytes in addition to hydrophobic interactions under RP elution conditions. Based on the mixed-mode properties, off-line 2D-LC, for selective capture and separation of urinary nucleosides, was successfully realized on a single column, demonstrating its powerful application potential for complex samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. 40 CFR 60.666 - Reconstruction.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Volatile Organic Compound (VOC) Emissions From Synthetic Organic Chemical Manufacturing Industry (SOCMI) Distillation Operations § 60.666...

  16. 40 CFR 60.662 - Standards.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Volatile Organic Compound (VOC) Emissions From Synthetic Organic Chemical Manufacturing Industry (SOCMI) Distillation Operations § 60.662...

  17. 40 CFR 60.662 - Standards.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Volatile Organic Compound (VOC) Emissions From Synthetic Organic Chemical Manufacturing Industry (SOCMI) Distillation Operations § 60.662...

  18. 40 CFR 60.662 - Standards.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Volatile Organic Compound (VOC) Emissions From Synthetic Organic Chemical Manufacturing Industry (SOCMI) Distillation Operations § 60.662...

  19. 40 CFR 60.666 - Reconstruction.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Volatile Organic Compound (VOC) Emissions From Synthetic Organic Chemical Manufacturing Industry (SOCMI) Distillation Operations § 60.666...

  20. Signal Restoration of Non-stationary Acoustic Signals in the Time Domain

    NASA Technical Reports Server (NTRS)

    Babkin, Alexander S.

    1988-01-01

    Signal restoration is a method of transforming a nonstationary signal acquired by a ground based microphone to an equivalent stationary signal. The benefit of the signal restoration is a simplification of the flight test requirements because it could dispense with the need to acquire acoustic data with another aircraft flying in concert with the rotorcraft. The data quality is also generally improved because the contamination of the signal by the propeller and wind noise is not present. The restoration methodology can also be combined with other data acquisition methods, such as a multiple linear microphone array for further improvement of the test results. The methodology and software are presented for performing the signal restoration in the time domain. The method has no restrictions on flight path geometry or flight regimes. Only requirement is that the aircraft spatial position be known relative to the microphone location and synchronized with the acoustic data. The restoration process assumes that the moving source radiates a stationary signal, which is then transformed into a nonstationary signal by various modulation processes. The restoration contains only the modulation due to the source motion.

  1. Initial clinical evaluation of stationary digital chest tomosynthesis

    NASA Astrophysics Data System (ADS)

    Hartman, Allison E.; Shan, Jing; Wu, Gongting; Lee, Yueh Z.; Zhou, Otto; Lu, Jianping; Heath, Michael; Wang, Xiaohui; Foos, David

    2016-03-01

    Computed Tomography (CT) is the gold standard for image evaluation of lung disease, including lung cancer and cystic fibrosis. It provides detailed information of the lung anatomy and lesions, but at a relatively high cost and high dose of radiation. Chest radiography is a low dose imaging modality but it has low sensitivity. Digital chest tomosynthesis (DCT) is an imaging modality that produces 3D images by collecting x-ray projection images over a limited angle. DCT is less expensive than CT and requires about 1/10th the dose of radiation. Commercial DCT systems acquire the projection images by mechanically scanning an x-ray tube. The movement of the tube head limits acquisition speed. We recently demonstrated the feasibility of stationary digital chest tomosynthesis (s-DCT) using a carbon nanotube (CNT) x-ray source array in benchtop phantom studies. The stationary x-ray source allows for fast image acquisition. The objective of this study is to demonstrate the feasibility of s-DCT for patient imaging. We have successfully imaged 31 patients. Preliminary evaluation by board certified radiologists suggests good depiction of thoracic anatomy and pathology.

  2. The penta-prism LTP: A long-trace-profiler with stationary optical head and moving penta prism (abstract)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qian, S.; Jark, W.; Takacs, P.Z.

    1995-02-01

    Metrology requirements for optical components for third generation synchrotron sources are taxing the state-of-the-art in manufacturing technology. We have investigated a number of effect sources in a commercial figure measurement instrument, the Long Trace Profiler II (LTP II), and have demonstrated that, with some simple modifications, we can significantly reduce the effect of error sources and improve the accuracy and reliability of the measurement. By keeping the optical head stationary and moving a penta prism along the translation stage, the stability of the optical system is greatly improved, and the remaining error signals can be corrected by a simple referencemore » beam subtraction. We illustrate the performance of the modified system by investigating the distortion produced by gravity on a typical synchrotron mirror and demonstrate the repeatability of the instrument despite relaxed tolerances on the translation stage.« less

  3. Removal of EOG Artifacts from EEG Recordings Using Stationary Subspace Analysis

    PubMed Central

    Zeng, Hong; Song, Aiguo

    2014-01-01

    An effective approach is proposed in this paper to remove ocular artifacts from the raw EEG recording. The proposed approach first conducts the blind source separation on the raw EEG recording by the stationary subspace analysis (SSA) algorithm. Unlike the classic blind source separation algorithms, SSA is explicitly tailored to the understanding of distribution changes, where both the mean and the covariance matrix are taken into account. In addition, neither independency nor uncorrelation is required among the sources by SSA. Thereby, it can concentrate artifacts in fewer components than the representative blind source separation methods. Next, the components that are determined to be related to the ocular artifacts are projected back to be subtracted from EEG signals, producing the clean EEG data eventually. The experimental results on both the artificially contaminated EEG data and real EEG data have demonstrated the effectiveness of the proposed method, in particular for the cases where limited number of electrodes are used for the recording, as well as when the artifact contaminated signal is highly nonstationary and the underlying sources cannot be assumed to be independent or uncorrelated. PMID:24550696

  4. Development of a stationary chest tomosynthesis system using carbon nanotube x-ray source array

    NASA Astrophysics Data System (ADS)

    Shan, Jing

    X-ray imaging system has shown its usefulness for providing quick and easy access of imaging in both clinic settings and emergency situations. It greatly improves the workflow in hospitals. However, the conventional radiography systems, lacks 3D information in the images. The tissue overlapping issue in the 2D projection image result in low sensitivity and specificity. Both computed tomography and digital tomosynthesis, the two conventional 3D imaging modalities, requires a complex gantry to mechanically translate the x-ray source to various positions. Over the past decade, our research group has developed a carbon nanotube (CNT) based x-ray source technology. The CNT x-ray sources allows compacting multiple x-ray sources into a single x-ray tube. Each individual x-ray source in the source array can be electronically switched. This technology allows development of stationary tomographic imaging modalities without any complex mechanical gantries. The goal of this work is to develop a stationary digital chest tomosynthesis (s-DCT) system, and implement it for a clinical trial. The feasibility of s-DCT was investigated. It is found that the CNT source array can provide sufficient x-ray output for chest imaging. Phantom images have shown comparable image qualities as conventional DCT. The s-DBT system was then used to study the effects of source array configurations and tomosynthesis image quality, and the feasibility of a physiological gated s-DCT. Using physical measures for spatial resolution, the 2D source configuration was shown to have improved depth resolution and comparable in-plane resolution. The prospective gated tomosynthesis images have shown substantially reduction of image blur associated with lung motions. The system was also used to investigate the feasibility of using s-DCT as a diagnosis and monitoring tools for cystic fibrosis patients. A new scatter reduction methods for s-DCT was also studied. Finally, a s-DCT system was constructed by retrofitting the source array to a Carestream digital radiography system. The system passed the electrical and radiation safety tests, and was installed in Marsico Hall. The patient trial started in March of 2015, and the first patient was successfully imaged.

  5. 40 CFR 60.668 - Delegation of authority.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Volatile Organic Compound (VOC) Emissions From Synthetic Organic Chemical Manufacturing Industry (SOCMI) Distillation Operations...

  6. 40 CFR 60.668 - Delegation of authority.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Volatile Organic Compound (VOC) Emissions From Synthetic Organic Chemical Manufacturing Industry (SOCMI) Distillation Operations...

  7. 40 CFR 61.30 - Applicability.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Applicability. The provisions of this subpart are applicable to the following stationary sources: (a) Extraction plants, ceramic plants, foundries, incinerators, and propellant plants which process beryllium ore...

  8. 40 CFR 61.30 - Applicability.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Applicability. The provisions of this subpart are applicable to the following stationary sources: (a) Extraction plants, ceramic plants, foundries, incinerators, and propellant plants which process beryllium ore...

  9. 40 CFR 52.2350 - Emission inventories.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...). This inventory addresses emissions from point, area, non-road, on-road mobile, and biogenic sources.... The ozone maintenance plan for Salt Lake and Davis Counties that the Governor submitted on February 19... carbon monoxide emissions from stationary point, area, non-road, and on-road mobile sources. (c) On June...

  10. California Air Quality State Implementation Plans; Final Approval; Butte County Air Quality Management District; Stationary Source Permits

    EPA Pesticide Factsheets

    EPA is taking final action to approve a revision to the Butte County Air Quality Management District (BCAQMD) portion of the California State Implementation Plan (SIP). This revision concerns the District's New Source Review (NSR) permitting program.

  11. Report on the First APCA Government Affairs Seminar "The Clean Air Act."

    ERIC Educational Resources Information Center

    Beery, Williamina, T.

    1973-01-01

    A summary of 18 speeches and sessions from the Government Affairs Seminar is given. Topics featured were emission standards for mobile sources, implementation strategies for stationary sources, non-degradation of air quality standards, and technology assessment and the National Environmental Policy Act. (BL)

  12. 40 CFR 52.1026 - Review of new sources and modifications.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    .... 52.1026 Section 52.1026 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Maine § 52.1026 Review... modified major stationary sources in non-attainment areas is approved as meeting the requirements of part D...

  13. 40 CFR 52.1026 - Review of new sources and modifications.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .... 52.1026 Section 52.1026 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Maine § 52.1026 Review... modified major stationary sources in non-attainment areas is approved as meeting the requirements of part D...

  14. 40 CFR 52.1026 - Review of new sources and modifications.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    .... 52.1026 Section 52.1026 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Maine § 52.1026 Review... modified major stationary sources in non-attainment areas is approved as meeting the requirements of part D...

  15. 40 CFR 52.1026 - Review of new sources and modifications.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... 52.1026 Section 52.1026 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Maine § 52.1026 Review... modified major stationary sources in non-attainment areas is approved as meeting the requirements of part D...

  16. 40 CFR 52.1026 - Review of new sources and modifications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .... 52.1026 Section 52.1026 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Maine § 52.1026 Review... modified major stationary sources in non-attainment areas is approved as meeting the requirements of part D...

  17. Summary Report for the Workshop on Integrating Climate Change Adaption into Air Quality Decision Making

    EPA Science Inventory

    Over the past few decades, air quality planners have forecasted future air pollution levels based on information about changing emissions from stationary and mobile sources, population trends, transportation demand, natural sources of emissions, and other pressures on air quality...

  18. Stochastic or statistic? Comparing flow duration curve models in ungauged basins and changing climates

    NASA Astrophysics Data System (ADS)

    Müller, M. F.; Thompson, S. E.

    2015-09-01

    The prediction of flow duration curves (FDCs) in ungauged basins remains an important task for hydrologists given the practical relevance of FDCs for water management and infrastructure design. Predicting FDCs in ungauged basins typically requires spatial interpolation of statistical or model parameters. This task is complicated if climate becomes non-stationary, as the prediction challenge now also requires extrapolation through time. In this context, process-based models for FDCs that mechanistically link the streamflow distribution to climate and landscape factors may have an advantage over purely statistical methods to predict FDCs. This study compares a stochastic (process-based) and statistical method for FDC prediction in both stationary and non-stationary contexts, using Nepal as a case study. Under contemporary conditions, both models perform well in predicting FDCs, with Nash-Sutcliffe coefficients above 0.80 in 75 % of the tested catchments. The main drives of uncertainty differ between the models: parameter interpolation was the main source of error for the statistical model, while violations of the assumptions of the process-based model represented the main source of its error. The process-based approach performed better than the statistical approach in numerical simulations with non-stationary climate drivers. The predictions of the statistical method under non-stationary rainfall conditions were poor if (i) local runoff coefficients were not accurately determined from the gauge network, or (ii) streamflow variability was strongly affected by changes in rainfall. A Monte Carlo analysis shows that the streamflow regimes in catchments characterized by a strong wet-season runoff and a rapid, strongly non-linear hydrologic response are particularly sensitive to changes in rainfall statistics. In these cases, process-based prediction approaches are strongly favored over statistical models.

  19. Comparing statistical and process-based flow duration curve models in ungauged basins and changing rain regimes

    NASA Astrophysics Data System (ADS)

    Müller, M. F.; Thompson, S. E.

    2016-02-01

    The prediction of flow duration curves (FDCs) in ungauged basins remains an important task for hydrologists given the practical relevance of FDCs for water management and infrastructure design. Predicting FDCs in ungauged basins typically requires spatial interpolation of statistical or model parameters. This task is complicated if climate becomes non-stationary, as the prediction challenge now also requires extrapolation through time. In this context, process-based models for FDCs that mechanistically link the streamflow distribution to climate and landscape factors may have an advantage over purely statistical methods to predict FDCs. This study compares a stochastic (process-based) and statistical method for FDC prediction in both stationary and non-stationary contexts, using Nepal as a case study. Under contemporary conditions, both models perform well in predicting FDCs, with Nash-Sutcliffe coefficients above 0.80 in 75 % of the tested catchments. The main drivers of uncertainty differ between the models: parameter interpolation was the main source of error for the statistical model, while violations of the assumptions of the process-based model represented the main source of its error. The process-based approach performed better than the statistical approach in numerical simulations with non-stationary climate drivers. The predictions of the statistical method under non-stationary rainfall conditions were poor if (i) local runoff coefficients were not accurately determined from the gauge network, or (ii) streamflow variability was strongly affected by changes in rainfall. A Monte Carlo analysis shows that the streamflow regimes in catchments characterized by frequent wet-season runoff and a rapid, strongly non-linear hydrologic response are particularly sensitive to changes in rainfall statistics. In these cases, process-based prediction approaches are favored over statistical models.

  20. On the application of Rice's exceedance statistics to atmospheric turbulence.

    NASA Technical Reports Server (NTRS)

    Chen, W. Y.

    1972-01-01

    Discrepancies produced by the application of Rice's exceedance statistics to atmospheric turbulence are examined. First- and second-order densities from several data sources have been measured for this purpose. Particular care was paid to each selection of turbulence that provides stationary mean and variance over the entire segment. Results show that even for a stationary segment of turbulence, the process is still highly non-Gaussian, in spite of a Gaussian appearance for its first-order distribution. Data also indicate strongly non-Gaussian second-order distributions. It is therefore concluded that even stationary atmospheric turbulence with a normal first-order distribution cannot be considered a Gaussian process, and consequently the application of Rice's exceedance statistics should be approached with caution.

  1. Artificial Dipolar Molecular Rotors

    NASA Astrophysics Data System (ADS)

    Horansky, R. D.; Magnera, T. F.; Price, J. C.; Michl, J.

    Rotors are present in almost every macroscopic machine, converting rotational motion into energy of other forms, or converting other forms of energy into rotation. Rotation may be transmitted via belts or gears, converted into linear motion by various linkages, or used to drive propellers to produce fluid motion. Examples of macroscopic rotors include engines which couple to combustible energy sources, windmills which couple to air flows, and most generators of electricity. A key feature of these objects is the presence of a part with rotational freedom relative to a stationary frame. In this chapter we discuss the miniaturization of rotary machines all the way to the molecular scale, where chemical groups form the rotary and stationary parts. For a recent review of molecules with rotary and stationary parts see [1].

  2. Deep neural network and noise classification-based speech enhancement

    NASA Astrophysics Data System (ADS)

    Shi, Wenhua; Zhang, Xiongwei; Zou, Xia; Han, Wei

    2017-07-01

    In this paper, a speech enhancement method using noise classification and Deep Neural Network (DNN) was proposed. Gaussian mixture model (GMM) was employed to determine the noise type in speech-absent frames. DNN was used to model the relationship between noisy observation and clean speech. Once the noise type was determined, the corresponding DNN model was applied to enhance the noisy speech. GMM was trained with mel-frequency cepstrum coefficients (MFCC) and the parameters were estimated with an iterative expectation-maximization (EM) algorithm. Noise type was updated by spectrum entropy-based voice activity detection (VAD). Experimental results demonstrate that the proposed method could achieve better objective speech quality and smaller distortion under stationary and non-stationary conditions.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garcia-Reyes, Gonzalo; Gonzalez, Guillermo A.

    The interpretation of a family of electrovacuum stationary Taub-NUT-type fields in terms of finite charged perfect fluid disks is presented. The interpretation is made by means of an 'inverse problem' approach used to obtain disk sources of known solutions of the Einstein or Einstein-Maxwell equations. The diagonalization of the energy-momentum tensor of the disks is facilitated in this case by the fact that it can be written as an upper right triangular matrix. We find that the inclusion of electromagnetic fields changes significantly the different material properties of the disks and so we can obtain, for some values of themore » parameters, finite charged perfect fluid disks that are in agreement with all the energy conditions.« less

  4. Thin-layer chromatography and mass spectrometry coupled using proximal probe thermal desorption with electrospray or atmospheric pressure chemical ionization.

    PubMed

    Ovchinnikova, Olga S; Van Berkel, Gary J

    2010-06-30

    An atmospheric pressure proximal probe thermal desorption sampling method coupled with secondary ionization by electrospray or atmospheric pressure chemical ionization was demonstrated for the mass spectrometric analysis of a diverse set of compounds (dyestuffs, pharmaceuticals, explosives and pesticides) separated on various high-performance thin-layer chromatography plates. Line scans along or through development lanes on the plates were carried out by moving the plate relative to a stationary heated probe positioned close to or just touching the stationary phase surface. Vapors of the compounds thermally desorbed from the surface were drawn into the ionization region of a combined electrospray ionization/atmospheric pressure chemical ionization source where they merged with reagent ions and/or charged droplets from a corona discharge or an electrospray emitter and were ionized. The ionized components were then drawn through the atmospheric pressure sampling orifice into the vacuum region of a triple quadrupole mass spectrometer and detected using full scan, single ion monitoring, or selected reaction monitoring mode. Studies of variable parameters and performance metrics including the proximal probe temperature, gas flow rate into the ionization region, surface scan speed, read-out resolution, detection limits, and surface type are discussed.

  5. Statistical Traffic Anomaly Detection in Time-Varying Communication Networks

    DTIC Science & Technology

    2015-02-01

    methods perform better than their vanilla counterparts, which assume that normal traffic is stationary. Statistical Traffic Anomaly Detection in Time...our methods perform better than their vanilla counterparts, which assume that normal traffic is stationary. Index Terms—Statistical anomaly detection...anomaly detection but also for understanding the normal traffic in time-varying networks. C. Comparison with vanilla stochastic methods For both types

  6. Statistical Traffic Anomaly Detection in Time Varying Communication Networks

    DTIC Science & Technology

    2015-02-01

    methods perform better than their vanilla counterparts, which assume that normal traffic is stationary. Statistical Traffic Anomaly Detection in Time...our methods perform better than their vanilla counterparts, which assume that normal traffic is stationary. Index Terms—Statistical anomaly detection...anomaly detection but also for understanding the normal traffic in time-varying networks. C. Comparison with vanilla stochastic methods For both types

  7. 40 CFR 467.61 - Specialized definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... AND STANDARDS (CONTINUED) ALUMINUM FORMING POINT SOURCE CATEGORY Drawing With Emulsions or Soaps... with emulsions or soaps subcategory shall include drawing using emulsions or soaps, stationary casting...

  8. 40 CFR 467.61 - Specialized definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... AND STANDARDS (CONTINUED) ALUMINUM FORMING POINT SOURCE CATEGORY Drawing With Emulsions or Soaps... with emulsions or soaps subcategory shall include drawing using emulsions or soaps, stationary casting...

  9. 40 CFR 60.702 - Standards.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Volatile Organic Compound Emissions From Synthetic Organic Chemical Manufacturing Industry (SOCMI) Reactor Processes § 60.702 Standards. Each owner...

  10. 40 CFR 60.702 - Standards.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Volatile Organic Compound Emissions From Synthetic Organic Chemical Manufacturing Industry (SOCMI) Reactor Processes § 60.702 Standards. Each owner...

  11. 40 CFR 60.706 - Reconstruction.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Volatile Organic Compound Emissions From Synthetic Organic Chemical Manufacturing Industry (SOCMI) Reactor Processes § 60.706 Reconstruction. (a) For...

  12. 40 CFR 60.706 - Reconstruction.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Volatile Organic Compound Emissions From Synthetic Organic Chemical Manufacturing Industry (SOCMI) Reactor Processes § 60.706 Reconstruction. (a) For...

  13. 40 CFR 467.61 - Specialized definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... AND STANDARDS (CONTINUED) ALUMINUM FORMING POINT SOURCE CATEGORY Drawing With Emulsions or Soaps... with emulsions or soaps subcategory shall include drawing using emulsions or soaps, stationary casting...

  14. 40 CFR 60.221 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for the Phosphate Fertilizer Industry... ammonia. (b) Total fluorides means elemental fluorine and all fluoride compounds as measured by reference...

  15. 40 CFR 60.221 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for the Phosphate Fertilizer Industry... ammonia. (b) Total fluorides means elemental fluorine and all fluoride compounds as measured by reference...

  16. 40 CFR 60.221 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for the Phosphate Fertilizer Industry... ammonia. (b) Total fluorides means elemental fluorine and all fluoride compounds as measured by reference...

  17. 40 CFR 60.221 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for the Phosphate Fertilizer Industry... ammonia. (b) Total fluorides means elemental fluorine and all fluoride compounds as measured by reference...

  18. 40 CFR 60.221 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for the Phosphate Fertilizer Industry... ammonia. (b) Total fluorides means elemental fluorine and all fluoride compounds as measured by reference...

  19. Air Emission Inventory for the INEEL -- 1999 Emission Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zohner, Steven K

    2000-05-01

    This report presents the 1999 calendar year update of the Air Emission Inventory for the Idaho National Engineering and Environmental Laboratory (INEEL). The INEEL Air Emission Inventory documents sources and emissions of nonradionuclide pollutants from operations at the INEEL. The report describes the emission inventory process and all of the sources at the INEEL, and provides nonradionuclide emissions estimates for stationary sources.

  20. Precision grid survey apparatus and method for the mapping of hidden ferromagnetic structures

    DOEpatents

    von Wimmerspeg, Udo

    2004-11-16

    The present invention is for a precision grid surveyor having a stationary unit and a roving unit. The stationary unit has a light source unit that emits a light beam and a rotator to project the light beam toward detectors on a roving unit. The roving unit moves over an area to be surveyed. Further the invention is for a method of mapping details of hidden underground iron pipelines, and more particularly the location of bell joints.

  1. Translation of waves along quantum vortex filaments in the low-temperature two-dimensional local induction approximation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Van Gorder, Robert A., E-mail: Robert.VanGorder@maths.ox.ac.uk

    2015-09-15

    In a recent paper, we give a study of the purely rotational motion of general stationary states in the two-dimensional local induction approximation (2D-LIA) governing superfluid turbulence in the low-temperature limit [B. Svistunov, “Superfluid turbulence in the low-temperature limit,” Phys. Rev. B 52, 3647 (1995)]. Such results demonstrated that variety of stationary configurations are possible from vortex filaments exhibiting purely rotational motion in addition to commonly discussed configurations such as helical or planar states. However, the filaments (or, more properly, waves along these filaments) can also exhibit translational motion along the axis of orientation. In contrast to the study onmore » vortex configurations for purely rotational stationary states, the present paper considers non-stationary states which exhibit a combination of rotation and translational motions. These solutions can essentially be described as waves or disturbances which ride along straight vortex filament lines. As expected from our previous work, there are a number of types of structures that can be obtained under the 2D-LIA. We focus on non-stationary states, as stationary states exhibiting translation will essentially take the form of solutions studied in [R. A. Van Gorder, “General rotating quantum vortex filaments in the low-temperature Svistunov model of the local induction approximation,” Phys. Fluids 26, 065105 (2014)], with the difference being translation along the reference axis, so that qualitative appearance of the solution geometry will be the same (even if there are quantitative differences). We discuss a wide variety of general properties of these non-stationary solutions and derive cases in which they reduce to known stationary states. We obtain various routes to Kelvin waves along vortex filaments and demonstrate that if the phase and amplitude of a disturbance both propagate with the same wave speed, then Kelvin waves will result. We also consider the self-similar solutions to the model and demonstrate that these types of solutions can model vortex kinks that gradually smooth and radiate Kelvin waves as time increases. Such solutions qualitatively agree with what one might expect from post-reconnection events.« less

  2. 40 CFR 51.117 - Additional provisions for lead.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... requirements apply to lead. To the extent they conflict, there requirements are controlling over those of the... the following point sources of lead: Primary lead smelters, Secondary lead smelters, Primary copper... or more batteries per day. Any other stationary source that actually emits 25 or more tons per year...

  3. 78 FR 46552 - Approval and Promulgation of Air Quality Implementation Plans; Massachusetts; Regulations...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-01

    ... Volatile Organic Compounds and Nitrogen Oxides AGENCY: Environmental Protection Agency (EPA). ACTION... requirements for stationary sources of volatile organic compounds (VOCs) and nitrogen oxides (NO X ). This... to 310 CMR 7.19, Reasonably Available Control Technology (RACT) for Sources of Oxides of Nitrogen (NO...

  4. 76 FR 26933 - Approval and Promulgation of Implementation Plans; Connecticut: Prevention of Significant...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-10

    ... Significant Deterioration (PSD) program. First, the revision provides Connecticut with authority to issue PSD... determining which new stationary sources and modification projects become subject to Connecticut's PSD... required to apply its PSD program to GHG- emitting sources, and unless it does so (or unless EPA...

  5. 76 FR 9658 - Approval and Promulgation of Implementation Plans; Kansas: Prevention of Significant...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-22

    ... greenhouse gas (GHG) under Kansas's New Source Review (NSR) Prevention of Significant Deterioration (PSD) program. First, the SIP revision provides the State of Kansas with authority to issue PSD permits... stationary sources and modification projects become subject to Kansas's PSD permitting requirements for their...

  6. EVALUATION OF POSSIBLE BIASES IN THE U.S. EPA'S METHOD 101A-MERCURY EMISSIONS FROM STATIONARY SOURCES

    EPA Science Inventory

    The U.S. Environmental Protection Agency (EPA), Research Triangle Park, North Carolina, has a program to evaluate and standardize source testing methods for hazardous pollutants in support of current and future air quality regulations. ccasionally, questions arise concerning an e...

  7. Screening Methodologies to Support Risk and Technology Reviews (RTR): A Case Study Analysis

    EPA Science Inventory

    The Clean Air Act establishes a two-stage regulatory process for addressing emissions of hazardous air pollutants (HAPs) from stationary sources. In the first stage, the Act requires the EPA to develop technology-based standards for categories of industrial sources. We have lar...

  8. 40 CFR 60.252 - Standards for thermal dryers.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) heat input. (iii) Thermal dryers that receive all of their thermal input from a source other than coal... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Coal Preparation.../MMBtu) heat input; or (ii) The owner or operator must not cause to be discharged into the atmosphere...

  9. DOE Hydrogen & Fuel Cell Overview

    DTIC Science & Technology

    2011-01-13

    Overview of Combined Heat+Power PowerElectricity Natural Gas Heat + Cooling Natural Gas or Biogas ...Fuel Cell Technologies Program eere.energy.gov Source: US DOE 10/2010 Biogas Benefits: Preliminary Analysis Stationary fuel...with the national grid. Source: US DOE 1/2011 6 | Fuel Cell Technologies Program eere.energy.gov Biogas Resource Example

  10. California; Bay Area Air Quality Management District; Proposed Approval of Stationary Sources New Source Review

    EPA Pesticide Factsheets

    EPA is making an interim final determination to defer imposition of sanctions based on a proposed determination that CARB submitted rules on behalf of BAAQMD that satisfy part D of the Clean Air Act for areas under the jurisdiction of the BAAQMD.

  11. 40 CFR 467.61 - Specialized definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... AND STANDARDS ALUMINUM FORMING POINT SOURCE CATEGORY Drawing With Emulsions or Soaps Subcategory § 467... emulsions or soaps subcategory shall include drawing using emulsions or soaps, stationary casting...

  12. 40 CFR 60.708 - Delegation of authority.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Volatile Organic Compound Emissions From Synthetic Organic Chemical Manufacturing Industry (SOCMI) Reactor Processes § 60.708...

  13. 40 CFR 60.708 - Delegation of authority.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Volatile Organic Compound Emissions From Synthetic Organic Chemical Manufacturing Industry (SOCMI) Reactor Processes § 60.708...

  14. 40 CFR 60.371 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Lead-Acid Battery Manufacturing Plants... lead compounds for the plates and sulfuric acid for the electrolyte. (c) Lead oxide manufacturing...

  15. 40 CFR 60.371 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Lead-Acid Battery Manufacturing Plants... lead compounds for the plates and sulfuric acid for the electrolyte. (c) Lead oxide manufacturing...

  16. 40 CFR 60.371 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Lead-Acid Battery Manufacturing Plants... lead compounds for the plates and sulfuric acid for the electrolyte. (c) Lead oxide manufacturing...

  17. 40 CFR 60.371 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Lead-Acid Battery Manufacturing Plants... lead compounds for the plates and sulfuric acid for the electrolyte. (c) Lead oxide manufacturing...

  18. 40 CFR 60.371 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Lead-Acid Battery Manufacturing Plants... lead compounds for the plates and sulfuric acid for the electrolyte. (c) Lead oxide manufacturing...

  19. A comparison of rotary- and stationary-head tape recorders

    NASA Technical Reports Server (NTRS)

    Watkinson, John R.

    1994-01-01

    Digital recording may take advantage of many types of media, but usually a preferred type of drive or transport emerges for each. In magnetic tape recording, two approaches have emerged in which essentially the same medium is tracked in two radically different ways. This paper compares the characteristics of Rotary- and Stationary-Head transports in an attempt to establish which approach might be considered for a given application. The conclusion is that in many cases there is no obvious choice based on recording physics and that often the choice will be made on the experimental knowledge of the designer.

  20. Exact Solutions in Three-Dimensional Gravity

    NASA Astrophysics Data System (ADS)

    García-Díaz, Alberto A.

    2017-09-01

    Preface; 1. Introduction; 2. Point particles; 3. Dust solutions; 4. AdS cyclic symmetric stationary solutions; 5. Perfect fluid static stars; 6. Static perfect fluid stars with Λ; 7. Hydrodynamic equilibrium; 8. Stationary perfect fluid with Λ; 9. Friedmann–Robertson–Walker cosmologies; 10. Dilaton-inflaton FRW cosmologies; 11. Einstein–Maxwell solutions; 12. Nonlinear electrodynamics black hole; 13. Dilaton minimally coupled to gravity; 14. Dilaton non-minimally coupled to gravity; 15. Low energy 2+1 string gravity; 16. Topologically massive gravity; 17. Bianchi type spacetimes in TMG; 18. Petrov type N wave metrics; 19. Kundt spacetimes in TMG; 20. Cotton tensor in Riemannian spacetimes; References; Index.

  1. Time-dependent probability density functions and information geometry in stochastic logistic and Gompertz models

    NASA Astrophysics Data System (ADS)

    Tenkès, Lucille-Marie; Hollerbach, Rainer; Kim, Eun-jin

    2017-12-01

    A probabilistic description is essential for understanding growth processes in non-stationary states. In this paper, we compute time-dependent probability density functions (PDFs) in order to investigate stochastic logistic and Gompertz models, which are two of the most popular growth models. We consider different types of short-correlated multiplicative and additive noise sources and compare the time-dependent PDFs in the two models, elucidating the effects of the additive and multiplicative noises on the form of PDFs. We demonstrate an interesting transition from a unimodal to a bimodal PDF as the multiplicative noise increases for a fixed value of the additive noise. A much weaker (leaky) attractor in the Gompertz model leads to a significant (singular) growth of the population of a very small size. We point out the limitation of using stationary PDFs, mean value and variance in understanding statistical properties of the growth in non-stationary states, highlighting the importance of time-dependent PDFs. We further compare these two models from the perspective of information change that occurs during the growth process. Specifically, we define an infinitesimal distance at any time by comparing two PDFs at times infinitesimally apart and sum these distances in time. The total distance along the trajectory quantifies the total number of different states that the system undergoes in time, and is called the information length. We show that the time-evolution of the two models become more similar when measured in units of the information length and point out the merit of using the information length in unifying and understanding the dynamic evolution of different growth processes.

  2. Extraction of angle deterministic signals in the presence of stationary speed fluctuations with cyclostationary blind source separation

    NASA Astrophysics Data System (ADS)

    Delvecchio, S.; Antoni, J.

    2012-02-01

    This paper addresses the use of a cyclostationary blind source separation algorithm (namely RRCR) to extract angle deterministic signals from mechanical rotating machines in presence of stationary speed fluctuations. This means that only phase fluctuations while machine is running in steady-state conditions are considered while run-up or run-down speed variations are not taken into account. The machine is also supposed to run in idle conditions so non-stationary phenomena due to the load are not considered. It is theoretically assessed that in such operating conditions the deterministic (periodic) signal in the angle domain becomes cyclostationary at first and second orders in the time domain. This fact justifies the use of the RRCR algorithm, which is able to directly extract the angle deterministic signal from the time domain without performing any kind of interpolation. This is particularly valuable when angular resampling fails because of uncontrolled speed fluctuations. The capability of the proposed approach is verified by means of simulated and actual vibration signals captured on a pneumatic screwdriver handle. In this particular case not only the extraction of the angle deterministic part can be performed but also the separation of the main sources of excitation (i.e. motor shaft imbalance, epyciloidal gear meshing and air pressure forces) affecting the user hand during operations.

  3. 40 CFR 60.544 - Monitoring of operations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for the Rubber Tire... organic compounds based on a detection principle such as infrared, photoionization, or thermal...

  4. Influence of the noise sources motion on the estimated Green's functions from ambient noise cross-correlations.

    PubMed

    Sabra, Karim G

    2010-06-01

    It has been demonstrated theoretically and experimentally that an estimate of the Green's function between two receivers can be obtained by cross-correlating acoustic (or elastic) ambient noise recorded at these two receivers. Coherent wavefronts emerge from the noise cross-correlation time function due to the accumulated contributions over time from noise sources whose propagation path pass through both receivers. Previous theoretical studies of the performance of this passive imaging technique have assumed that no relative motion between noise sources and receivers occurs. In this article, the influence of noise sources motion (e.g., aircraft or ship) on this passive imaging technique was investigated theoretically in free space, using a stationary phase approximation, for stationary receivers. The theoretical results were extended to more complex environments, in the high-frequency regime, using first-order expansions of the Green's function. Although sources motion typically degrades the performance of wideband coherent processing schemes, such as time-delay beamforming, it was found that the Green's function estimated from ambient noise cross-correlations are not expected to be significantly affected by the Doppler effect, even for supersonic sources. Numerical Monte-Carlo simulations were conducted to confirm these theoretical predictions for both cases of subsonic and supersonic moving sources.

  5. On the continuity of the stationary state distribution of DPCM

    NASA Astrophysics Data System (ADS)

    Naraghi-Pour, Morteza; Neuhoff, David L.

    1990-03-01

    Continuity and singularity properties of the stationary state distribution of differential pulse code modulation (DPCM) are explored. Two-level DPCM (i.e., delta modulation) operating on a first-order autoregressive source is considered, and it is shown that, when the magnitude of the DPCM prediciton coefficient is between zero and one-half, the stationary state distribution is singularly continuous; i.e., it is not discrete but concentrates on an uncountable set with a Lebesgue measure of zero. Consequently, it cannot be represented with a probability density function. For prediction coefficients with magnitude greater than or equal to one-half, the distribution is pure, i.e., either absolutely continuous and representable with a density function, or singular. This problem is compared to the well-known and still substantially unsolved problem of symmetric Bernoulli convolutions.

  6. The Growth Advantage in Stationary-Phase Phenotype Conferred by rpoS Mutations Is Dependent on the pH and Nutrient Environment

    PubMed Central

    Farrell, Michael J.; Finkel, Steven E.

    2003-01-01

    Escherichia coli cells that are aged in batch culture display an increased fitness referred to as the growth advantage in stationary phase, or GASP, phenotype. A common early adaptation to this culture environment is a mutant rpoS allele, such as rpoS819, that results in attenuated RpoS activity. However, it is important to note that during long-term batch culture, environmental conditions are in flux. To date, most studies of the GASP phenotype have focused on identifying alleles that render an advantage in a specific environment, Luria-Bertani broth (LB) batch culture. To determine what role environmental conditions play in rendering relative fitness advantages to E. coli cells carrying either the wild-type or rpoS819 alleles, we performed competitions under a variety of culture conditions in which either the available nutrients, the pH, or both were manipulated. In LB medium, we found that while the rpoS819 allele confers a strong competitive fitness advantage at basic pH, it confers a reduced advantage under neutral conditions, and it is disadvantageous under acidic conditions. Similar results were found using other media. rpoS819 conferred its greatest advantage in basic minimal medium in which either glucose or Casamino Acids were the sole source of carbon and energy. In acidic medium supplemented with either Casamino Acids or glucose, the wild-type allele conferred a slight advantage. In addition, populations were dynamic under all pH conditions tested, with neither the wild-type nor mutant rpoS alleles sweeping a culture. We also found that the strength of the fitness advantage gained during a 10-day incubation is pH dependent. PMID:14645263

  7. Psychophysical Evaluation of Three-Dimensional Auditory Displays

    NASA Technical Reports Server (NTRS)

    Wightman, Frederic L.

    1996-01-01

    This report describes the progress made during the second year of a three-year Cooperative Research Agreement. The CRA proposed a program of applied psychophysical research designed to determine the requirements and limitations of three-dimensional (3-D) auditory display systems. These displays present synthesized stimuli to a pilot or virtual workstation operator that evoke auditory images at predetermined positions in space. The images can be either stationary or moving. In previous years, we completed a number of studies that provided data on listeners' abilities to localize stationary sound sources with 3-D displays. The current focus is on the use of 3-D displays in 'natural' listening conditions, which include listeners'head movements, moving sources, multiple sources and 'echoic' sources. The results of our research on one of these topics, the localization of multiple sources, was reported in the most recent Semi-Annual Progress Report (Appendix A). That same progress report described work on two related topics, the influence of a listener's a-priori knowledge of source characteristics and the discriminability of real and virtual sources. In the period since the last Progress Report we have conducted several new studies to evaluate the effectiveness of a new and simpler method for measuring the HRTF's that are used to synthesize virtual sources and have expanded our studies of multiple sources. The results of this research are described below.

  8. 40 CFR 60.566 - Delegation of authority.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Volatile Organic Compound (VOC) Emissions from the Polymer Manufacturing Industry § 60.566 Delegation of authority. (a) In...

  9. 40 CFR 60.473 - Monitoring of operations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Asphalt Processing and Asphalt Roofing Manufacture § 60.473 Monitoring of operations. (a) The owner or operator...

  10. 40 CFR 60.473 - Monitoring of operations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Asphalt Processing and Asphalt Roofing Manufacture § 60.473 Monitoring of operations. (a) The owner or operator...

  11. 40 CFR 60.473 - Monitoring of operations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Asphalt Processing and Asphalt Roofing Manufacture § 60.473 Monitoring of operations. (a) The owner or operator...

  12. 40 CFR 60.2720 - May I conduct performance testing less often?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emissions Guidelines and Compliance Times for Commercial and Industrial Solid Waste Incineration Units Model Rule-Continuous...

  13. 40 CFR 60.2720 - May I conduct performance testing less often?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emissions Guidelines and Compliance Times for Commercial and Industrial Solid Waste Incineration Units Model Rule-Continuous...

  14. 40 CFR Appendix to Part 240 - Recommended Bibliography

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .... 6. Zausner, E. R. An accounting system for incinerator operations. Public Health Service Publication.... Jaye. Performance Specifications for Stationary Source Monitoring Systems. NTIS PB. 230 934/AS (1974). ...

  15. Plasma Diffusion in Self-Consistent Fluctuations

    NASA Technical Reports Server (NTRS)

    Smets, R.; Belmont, G.; Aunai, N.

    2012-01-01

    The problem of particle diffusion in position space, as a consequence ofeleclromagnetic fluctuations is addressed. Numerical results obtained with a self-consistent hybrid code are presented, and a method to calculate diffusion coefficient in the direction perpendicular to the mean magnetic field is proposed. The diffusion is estimated for two different types of fluctuations. The first type (resuiting from an agyrotropic in itiai setting)is stationary, wide band white noise, and associated to Gaussian probability distribution function for the magnetic fluctuations. The second type (result ing from a Kelvin-Helmholtz instability) is non-stationary, with a power-law spectrum, and a non-Gaussian probabi lity distribution function. The results of the study allow revisiting the question of loading particles of solar wind origin in the Earth magnetosphere.

  16. Improved separation with the intermittently pressed tubing of multilayer coil in type-I counter-current chromatography.

    PubMed

    Yang, Yi; Yang, Jiao; Fang, Chen; Wang, Jihui; Gu, Dongyu; Tian, Jing; Ito, Yoichiro

    2018-05-25

    The intermittently pressed tubing was introduced in type-I counter-current chromatographic system as the separation column to improve the separation performance in the present study. The separations were performed with two different solvent systems composed of 1-butanol-acetic acid-water (4:1:5, v/v) (BAW) and hexane-ethyl acetate-methanol-0.1 M HCl (1:1:1:1, v/v) (HEMW) using dipeptides and DNP-amino acids as test samples, respectively. The chromatographic performance was evaluated in terms of retention of the stationary phase (Sf), theoretical plate (N) and peak resolution (Rs). In general, the type-I planetary motion with the multilayer coil of non-modified standard tubing can yield the best separation at a low revolution speed of 200 rpm with lower flow rate. The present results with intermittently pressed tubing indicated that the performance was also optimal at the revolution speed of 200 rpm where the lower flow rate was more beneficial to retention of stationary phase and resolution. In the moderately hydrophobic two-phase solvent system composed of hexane-ethyl acetate-metanol-0.1 M hydrochloric acid (1:1:1:1, v/v), DNP-amino acids were separated with Rs at 1.67 and 1.47, respectively, with 12.66% of stationary phase retention at a flow rate of 0.25 ml/min. In the polar solvent system composed of 1-butanol-acetic acid-water (4:1:5, v/v), dipeptide samples were resolved with Rs at 2.18 and 18.75% of stationary phase retention at a flow rate of 0.25 ml/min. These results indicate that the present system substantially improves the separation efficiency of type-I counter-current chromatographic system. Published by Elsevier B.V.

  17. 40 CFR Appendix A-4 to Part 60 - Test Methods 6 through 10B

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... sources Method 6A—Determination of sulfur dioxide, moisture, and carbon dioxide emissions from fossil fuel... fossil fuel combustion sources Method 6C—Determination of Sulfur Dioxide Emissions From Stationary... with SO2 to form particulate sulfite and by reacting with the indicator. If free ammonia is present...

  18. 40 CFR Appendix A-4 to Part 60 - Test Methods 6 through 10B

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... sources Method 6A—Determination of sulfur dioxide, moisture, and carbon dioxide emissions from fossil fuel... fossil fuel combustion sources Method 6C—Determination of Sulfur Dioxide Emissions From Stationary... with SO2 to form particulate sulfite and by reacting with the indicator. If free ammonia is present...

  19. 40 CFR Appendix A-4 to Part 60 - Test Methods 6 through 10B

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... sources Method 6A—Determination of sulfur dioxide, moisture, and carbon dioxide emissions from fossil fuel... fossil fuel combustion sources Method 6C—Determination of Sulfur Dioxide Emissions From Stationary... with SO2 to form particulate sulfite and by reacting with the indicator. If free ammonia is present...

  20. 78 FR 37752 - Approval and Promulgation of Air Quality Implementation Plans; Rescission of Federal...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-24

    ... files should avoid the use of special characters and any form of encryption and should be free of any... or decomposition of biologically-based materials other than fossil fuels and mineral sources of..., Wyoming should revise its SIP accordingly. For stationary sources co-firing fossil fuel and biologically...

  1. 40 CFR Appendix A-4 to Part 60 - Test Methods 6 through 10B

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... sources Method 6A—Determination of sulfur dioxide, moisture, and carbon dioxide emissions from fossil fuel... fossil fuel combustion sources Method 6C—Determination of Sulfur Dioxide Emissions From Stationary... reacting with SO2 to form particulate sulfite and by reacting with the indicator. If free ammonia is...

  2. 40 CFR Appendix A-4 to Part 60 - Test Methods 6 through 10B

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... sources Method 6A—Determination of sulfur dioxide, moisture, and carbon dioxide emissions from fossil fuel... fossil fuel combustion sources Method 6C—Determination of Sulfur Dioxide Emissions From Stationary... with SO2 to form particulate sulfite and by reacting with the indicator. If free ammonia is present...

  3. PLANNING OF HEALTH EFFECTS RESEARCH ON HAZARDOUS AIR POLLUTANTS AND APPLICATION TO RISK ASSESSMENT PROBLEMS

    EPA Science Inventory

    The Clean Air Act Amendment of 1990 designated a set of compounds as hazardous air pollutants or "air toxics" which may be released into the air from a variety of sources including stationary, mobile and indoor air sources. Determination of the risks to human health from exposur...

  4. 40 CFR 60.32d - Compliance times.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... PERFORMANCE FOR NEW STATIONARY SOURCES Emissions Guidelines and Compliance Times for Sulfuric Acid Production Units § 60.32d Compliance times. Sulfuric acid production units. Planning, awarding of contracts, and...

  5. 40 CFR 60.32d - Compliance times.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... PERFORMANCE FOR NEW STATIONARY SOURCES Emissions Guidelines and Compliance Times for Sulfuric Acid Production Units § 60.32d Compliance times. Sulfuric acid production units. Planning, awarding of contracts, and...

  6. 40 CFR 60.2645 - How do I obtain my operator qualification?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emissions Guidelines and Compliance Times for Commercial and Industrial Solid Waste Incineration Units Model Rule-Operator Training...

  7. 40 CFR 60.2650 - How do I maintain my operator qualification?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emissions Guidelines and Compliance Times for Commercial and Industrial Solid Waste Incineration Units Model Rule-Operator Training...

  8. 40 CFR 60.2650 - How do I maintain my operator qualification?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emissions Guidelines and Compliance Times for Commercial and Industrial Solid Waste Incineration Units Model Rule-Operator Training...

  9. 40 CFR 60.2645 - How do I obtain my operator qualification?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emissions Guidelines and Compliance Times for Commercial and Industrial Solid Waste Incineration Units Model Rule-Operator Training...

  10. Clearinghouse for Inventories and Emissions Factors

    EPA Pesticide Factsheets

    Emissions inventories, modeling, and monitoring are the basis for understanding, controlling and tracking stationary sources of air pollution. This technical site provides access to tools and data to support those efforts.

  11. 40 CFR 60.725 - Test methods and procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Industrial Surface Coating: Surface Coating of Plastic Parts for Business Machines § 60.725 Test methods and...

  12. 40 CFR 60.725 - Test methods and procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Industrial Surface Coating: Surface Coating of Plastic Parts for Business Machines § 60.725 Test methods and...

  13. Transition from moving to stationary double layers in a single-ended Q machine

    NASA Technical Reports Server (NTRS)

    Song, Bin; Merlino, R. L.; D'Angelo, N.

    1990-01-01

    Large-amplitude (less than about 100 percent) relaxation oscillations in the plasma potential are known to be generated when the cold endplate of a single-ended Q machine is biased positively. These oscillations are associated with double layers that form near the hot plate (plasma source) and travel toward the endplate at about the ion-acoustic velocity. At the endplate they dissolve and then form again near the hot plate, the entire process repeating itself in a regular manner. By admitting a sufficient amount of neutral gas into the system, the moving double layers were slowed down and eventually stopped. The production of stationary double layers requires an ion source on the high-potential side of the double layers. These ions are provided by ionization of the neutral gas by electrons that are accelerated through the double layer. The dependence of the critical neutral gas pressure required for stationary double-layer formation on endplate voltage, magnetic field strength, and neutral atom mass has been examined. These results are discussed in terms of a simple model of ion production and loss, including ion losses across the magnetic field.

  14. Cancellation of spurious arrivals in Green's function extraction and the generalized optical theorem

    USGS Publications Warehouse

    Snieder, R.; Van Wijk, K.; Haney, M.; Calvert, R.

    2008-01-01

    The extraction of the Green's function by cross correlation of waves recorded at two receivers nowadays finds much application. We show that for an arbitrary small scatterer, the cross terms of scattered waves give an unphysical wave with an arrival time that is independent of the source position. This constitutes an apparent inconsistency because theory predicts that such spurious arrivals do not arise, after integration over a complete source aperture. This puzzling inconsistency can be resolved for an arbitrary scatterer by integrating the contribution of all sources in the stationary phase approximation to show that the stationary phase contributions to the source integral cancel the spurious arrival by virtue of the generalized optical theorem. This work constitutes an alternative derivation of this theorem. When the source aperture is incomplete, the spurious arrival is not canceled and could be misinterpreted to be part of the Green's function. We give an example of how spurious arrivals provide information about the medium complementary to that given by the direct and scattered waves; the spurious waves can thus potentially be used to better constrain the medium. ?? 2008 The American Physical Society.

  15. The accelerator neutron source for boron neutron capture therapy

    NASA Astrophysics Data System (ADS)

    Kasatov, D.; Koshkarev, A.; Kuznetsov, A.; Makarov, A.; Ostreinov, Yu; Shchudlo, I.; Sorokin, I.; Sycheva, T.; Taskaev, S.; Zaidi, L.

    2016-11-01

    The accelerator based epithermal neutron source for Boron Neutron Capture Therapy (BNCT) is proposed, created and used in the Budker Institute of Nuclear Physics. In 2014, with the support of the Russian Science Foundation created the BNCT laboratory for the purpose to the end of 2016 get the neutron flux, suitable for BNCT. For getting 3 mA 2.3 MeV proton beam, was created a new type accelerator - tandem accelerator with vacuum isolation. On this moment, we have a stationary proton beam with 2.3 MeV and current 1.75 mA. Generation of neutrons is carried out by dropping proton beam on to lithium target as a result of threshold reaction 7Li(p,n)7Be. Established facility is a unique scientific installation. It provides a generating of neutron flux, including a monochromatic energy neutrons, gamma radiation, alpha-particles and positrons, and may be used by other research groups for carrying out scientific researches. The article describes an accelerator neutron source, presents and discusses the result of experiments and declares future plans.

  16. The sound field of a rotating dipole in a plug flow.

    PubMed

    Wang, Zhao-Huan; Belyaev, Ivan V; Zhang, Xiao-Zheng; Bi, Chuan-Xing; Faranosov, Georgy A; Dowell, Earl H

    2018-04-01

    An analytical far field solution for a rotating point dipole source in a plug flow is derived. The shear layer of the jet is modelled as an infinitely thin cylindrical vortex sheet and the far field integral is calculated by the stationary phase method. Four numerical tests are performed to validate the derived solution as well as to assess the effects of sound refraction from the shear layer. First, the calculated results using the derived formulations are compared with the known solution for a rotating dipole in a uniform flow to validate the present model in this fundamental test case. After that, the effects of sound refraction for different rotating dipole sources in the plug flow are assessed. Then the refraction effects on different frequency components of the signal at the observer position, as well as the effects of the motion of the source and of the type of source are considered. Finally, the effect of different sound speeds and densities outside and inside the plug flow is investigated. The solution obtained may be of particular interest for propeller and rotor noise measurements in open jet anechoic wind tunnels.

  17. 40 CFR 68.152 - Substantiating claims of confidential business information.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) CHEMICAL ACCIDENT PREVENTION PROVISIONS Risk Management Plan § 68.152..., operator, or senior official with management responsibility of the stationary source shall sign a...

  18. 40 CFR 60.2755 - When must I submit my waste management plan?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emissions Guidelines and Compliance Times for Commercial and Industrial Solid Waste Incineration Units Model Rule-Recordkeeping and...

  19. 40 CFR 60.2580 - When must I complete each increment of progress?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emissions Guidelines and Compliance Times for Commercial and Industrial Solid Waste Incineration Units Model Rule-Increments of...

  20. 40 CFR 60.2780 - What must I include in the deviation report?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emissions Guidelines and Compliance Times for Commercial and Industrial Solid Waste Incineration Units Model Rule-Recordkeeping and...

  1. 40 CFR 60.2740 - What records must I keep?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emissions Guidelines and Compliance Times for Commercial and Industrial Solid Waste Incineration Units Model Rule-Recordkeeping and Reporting § 60.2740...

  2. 40 CFR 60.2750 - What reports must I submit?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emissions Guidelines and Compliance Times for Commercial and Industrial Solid Waste Incineration Units Model Rule-Recordkeeping and Reporting § 60.2750...

  3. 40 CFR 60.2755 - When must I submit my waste management plan?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emissions Guidelines and Compliance Times for Commercial and Industrial Solid Waste Incineration Units Model Rule-Recordkeeping and...

  4. 40 CFR 60.2780 - What must I include in the deviation report?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emissions Guidelines and Compliance Times for Commercial and Industrial Solid Waste Incineration Units Model Rule-Recordkeeping and...

  5. 40 CFR 60.2625 - When must I submit my waste management plan?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emissions Guidelines and Compliance Times for Commercial and Industrial Solid Waste Incineration Units Model Rule-Waste Management...

  6. 40 CFR 60.2740 - What records must I keep?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emissions Guidelines and Compliance Times for Commercial and Industrial Solid Waste Incineration Units Model Rule-Recordkeeping and Reporting § 60.2740...

  7. 40 CFR 60.2750 - What reports must I submit?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emissions Guidelines and Compliance Times for Commercial and Industrial Solid Waste Incineration Units Model Rule-Recordkeeping and Reporting § 60.2750...

  8. 40 CFR 60.2820 - When must I complete each increment of progress?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emissions Guidelines and Compliance Times for Commercial and Industrial Solid Waste Incineration Units Model Rule-Air Curtain...

  9. 40 CFR 60.2580 - When must I complete each increment of progress?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emissions Guidelines and Compliance Times for Commercial and Industrial Solid Waste Incineration Units Model Rule-Increments of...

  10. 40 CFR 60.2625 - When must I submit my waste management plan?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emissions Guidelines and Compliance Times for Commercial and Industrial Solid Waste Incineration Units Model Rule-Waste Management...

  11. 40 CFR 60.2580 - When must I complete each increment of progress?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emissions Guidelines and Compliance Times for Commercial and Industrial Solid Waste Incineration Units Model Rule-Increments of...

  12. 40 CFR 60.290 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Glass Manufacturing Plants § 60.290 Applicability and designation of affected facility. (a...

  13. 40 CFR 60.80 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Sulfuric Acid Plants § 60.80 Applicability and designation of affected facility. (a) The...

  14. 40 CFR 60.80 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Sulfuric Acid Plants § 60.80 Applicability and designation of affected facility. (a) The...

  15. 40 CFR 60.12 - Circumvention.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... PERFORMANCE FOR NEW STATIONARY SOURCES General Provisions § 60.12 Circumvention. No owner or operator subject to the provisions of this part shall build, erect, install, or use any article, machine, equipment or...

  16. 40 CFR 60.726 - Delegation of authority.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Industrial Surface Coating: Surface Coating of Plastic Parts for Business Machines § 60.726 Delegation of authority. (a) In delegating...

  17. 40 CFR 60.726 - Delegation of authority.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Industrial Surface Coating: Surface Coating of Plastic Parts for Business Machines § 60.726 Delegation of authority. (a) In delegating...

  18. 40 CFR 60.12 - Circumvention.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... PERFORMANCE FOR NEW STATIONARY SOURCES General Provisions § 60.12 Circumvention. No owner or operator subject to the provisions of this part shall build, erect, install, or use any article, machine, equipment or...

  19. 40 CFR 60.120 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of...: Pot furnaces of more than 250 kg (550 lb) charging capacity, blast (cupola) furnaces, and...

  20. 40 CFR 60.120 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of...: Pot furnaces of more than 250 kg (550 lb) charging capacity, blast (cupola) furnaces, and...

  1. 40 CFR 60.143 - Monitoring of operations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... which the affected facility demonstrated compliance with the mass standards under § 60.142(a)(1), (b)(1... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Primary...

  2. 40 CFR 60.143 - Monitoring of operations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... which the affected facility demonstrated compliance with the mass standards under § 60.142(a)(1), (b)(1... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Primary...

  3. 40 CFR 60.143 - Monitoring of operations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... which the affected facility demonstrated compliance with the mass standards under § 60.142(a)(1), (b)(1... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Primary...

  4. 40 CFR 68.152 - Substantiating claims of confidential business information.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) CHEMICAL ACCIDENT PREVENTION PROVISIONS Risk Management Plan § 68.152..., operator, or senior official with management responsibility of the stationary source shall sign a...

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walker, B; Radtke, J; Chen, G

    Purpose: To develop and build a practical implementation of an x-ray line source for the rapidly increasing number of multi-source imaging applications in CT. Methods: An innovative x-ray tube was designed using CST Particle Studio, ANSYS, and SolidWorks. A slowly varying magnetic field is synchronized with microsecond gating of multiple thermionic electron sources. Electrostatic simulations were run to optimize the geometry of the optics and prevent electrode arcing. Magnetostatic simulations were used for beam deflection studies and solenoid design. Particle beam trajectories were explored with an emphasis on focusing, acceleration, deflection, and space charge effects. Thermal constraints were analyzed formore » both transient and steady-state regimes. Electromagnetic simulations informed the design of a prototype unit under construction. Results: Particle tracking simulations for a benchtop system demonstrate that three 80 keV electron beams are able to be finely controlled and laterally swept a combined distance of 15 cm over a stationary target with an oscillating magnetic field in the hundreds of gauss. The beams are pulsed according to scanning sequences developed for implementation in a mock stationary CT scanner capable of a 30 ms temporal resolution. Beam spot diameters are approximately 1 mm for 30 mA beams and the stationary target stays well within thermal limits. The relevant hardware and control circuits were developed for incorporation into a physical prototype. Conclusion: A new multi-source x-ray tube was designed in a modular form factor to push the barriers of high-speed CT and spur growth in emerging imaging applications. This technology can be used as the basis for a stationary high-speed CT scanner, a system for generating a virtual fan-beam for dose reduction, or for reducing scatter radiation in cone-beam CT utilizing a tetrahedron beam CT geometry. A 2.4 kW benchtop system is currently being built to show proof of concept for the tube. Support for this research was provided by the University of Wisconsin Madison, Office of the Vice Chancellor for Research and Graduate Education with funding from the Wisconsin Alumni Research Foundation.« less

  6. Evaluation of ionic liquid stationary phases for one dimensional gas chromatography-mass spectrometry and comprehensive two dimensional gas chromatographic analyses of fatty acids in marine biota.

    PubMed

    Gu, Qun; David, Frank; Lynen, Frédéric; Vanormelingen, Pieter; Vyverman, Wim; Rumpel, Klaus; Xu, Guowang; Sandra, Pat

    2011-05-20

    Ionic liquid stationary phases were tested for one dimensional gas chromatography-mass spectrometry (GC-MS) and comprehensive two dimensional gas chromatography (GC×GC) of fatty acid methyl esters from algae. In comparison with polyethylene glycol and cyanopropyl substituted polar stationary phases, ionic liquid stationary phases SLB-IL 82 and SLB-IL 100 showed comparable resolution, but lower column bleeding with MS detection, resulting in better sensitivity. The selectivity and polarity of the ionic liquid phases are similar to a highly polar biscyanopropyl-silicone phase (e.g. HP-88). In GC×GC, using an apolar polydimethyl siloxane×polar ionic liquid column combination, an excellent group-type separation of fatty acids with different carbon numbers and number of unsaturations was obtained, providing information that is complementary to GC-MS identification. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. Cost-Benefit Analysis Methodology: Install Commercially Compliant Engines on National Security Exempted Vessels?

    DTIC Science & Technology

    2015-11-05

    impact analyses) satisfactorily encompasses the fundamentals of environmental health risk and can be applied to all mobile and stationary equipment...regulations. This paper does not seek to justify the EPA MHB approach, but explains the fundamentals and describes how the MHB concept can be...satisfactorily encompasses the fundamentals of environmental health risk and can be applied to all mobile and stationary equipment types. 15. SUBJECT TERMS

  8. A chromatographic estimate of the degree of heterogeneity of RPLC packing materials. 1. Non-endcapped polymeric C30-bonded stationary phase

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gritti, Fabrice; Guiochon, Georges A

    2006-01-01

    A new chromatographic method estimating the degree of heterogeneity of RPLC packing materials is based on the results of systematic measurements of the adsorption data in a wide concentration range for selected probe compounds. These data are acquired by frontal analysis (FA), modeled, and used for the calculation of the adsorption energy distribution (AED). Four compounds were used, two neutral compounds of different molecular sizes (caffeine and phenol) and two ionizable compounds of opposite charges, 2-naphthalene sulfonate, an anion, and propranololium, a cation. This work was done on a C{sub 30}-bonded silica stationary phase (Prontosil-C{sub 30}), using the same aqueousmore » mobile phase (30% methanol, v/v) for all compounds, except that sodium chloride (25 mM) was added to elute the ionizable compounds. All four adsorption isotherms have Langmuirian behavior. The AEDs are tri-modal for phenol, quadri-modal for caffeine. The total saturation capacity of the stationary phase is four-fold lower for caffeine than for phenol, due in part to its larger molecular size. The equilibrium constants on the low-energy sites of types 1 and 2 are eight-fold larger. These two types of sites characterize the heterogeneity of the bonded layer itself. The density of the high-energy sites of types 3 and 4 is higher for caffeine, suggesting that caffeine molecules can be accommodated in some hydrophobic cages into which smaller molecules like phenol cannot. These high-energy types of sites characterize the heterogeneity of the whole stationary phase (silica support included). The ionizable compounds have larger molecules than the neutral ones and, accordingly, a lower relative density of sites of type 2 to sites of type 1. A tri-modal and a quadri-modal energy distributions were observed for the 2-naphthalene sulfonate anion and the propranololium cation, respectively. The fourth types of sites measured and its unusually high equilibrium constant are most probably due to ion-exchange interactions between the non-endcapped ionized silanols and the propranololium ion. No such strong interactions are observed with the anionic compound.« less

  9. Natural gas availability and ambient air quality in the Baton Rouge/New Orleans industrial complex

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fieler, E.R.; Harrison, D.P.

    1978-02-26

    Three scenarios were modeled for the Baton Rouge/New Orleans area for 1985: one assumes the substitution of residual oil (0.7% sulfur) for gas to decrease gas-burning stationary sources from 80 to 8% and the use of properly designed stacks for large emitters; the second makes identical gas supply assumptions but adds proper stack dispersion for medium as well as large emitters; and the third is based on 16% gas-burning stationary sources. The Climatological Dispersion Model was used to translate (1974) emission rates into ambient air concentrations. Growth rates for residential, commercial, and transportation sources, but not industry, were considered. Themore » results show that proper policies, which would require not only tall stacks for large oil burning units (and for intermediate units also in the areas of high industrial concentration), but also the careful location of new plants would permit continued industrial expansion without severe air pollution problems.« less

  10. The penta-prism LTP: A long-trace-profiler with stationary optical head and moving penta prism

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qian, S.; Jark, W.; Takacs, P.Z.

    1995-03-01

    Metrology requirements for optical components for third-generation synchrotron sources are taxing the state of the art in manufacturing technology. We have investigated a number of error sources in a commercial figure measurement instrument, the Long-Trace-Profiler II, and have demonstrated that, with some simple modifications, we can significantly reduce the effect of error sources and improve the accuracy and reliability of the measurement. By keeping the optical head stationary and moving a penta prism along the translation stage, as in the original pencil-beam interferometer design of von Bieren, the stability of the optical system is greatly improved, and the remaining errormore » signals can be corrected by a simple reference beam subtraction. We illustrate the performance of the modified system by investigating the distortion produced by gravity on a typical synchrotron mirror and demonstrate the repeatability of the instrument despite relaxed tolerances on the translation stage.« less

  11. The effect of barriers on wave propagation phenomena: With application for aircraft noise shielding

    NASA Technical Reports Server (NTRS)

    Mgana, C. V. M.; Chang, I. D.

    1982-01-01

    The frequency spectrum was divided into high and low frequency regimes and two separate methods were developed and applied to account for physical factors associated with flight conditions. For long wave propagation, the acoustic filed due to a point source near a solid obstacle was treated in terms of an inner region which where the fluid motion is essentially incompressible, and an outer region which is a linear acoustic field generated by hydrodynamic disturbances in the inner region. This method was applied to a case of a finite slotted plate modelled to represent a wing extended flap for both stationary and moving media. Ray acoustics, the Kirchhoff integral formulation, and the stationary phase approximation were combined to study short wave length propagation in many limiting cases as well as in the case of a semi-infinite plate in a uniform flow velocity with a point source above the plate and embedded in a different flow velocity to simulate an engine exhaust jet stream surrounding the source.

  12. Preparation and evaluation of diblock copolymer-grafted silica by sequential surface initiated-atom transfer radical polymerization for reverse-phase/ion-exchange mixed-mode chromatography.

    PubMed

    Bo, Chun Miao; Wang, Chaozhan; Wei, Yin Mao

    2017-12-01

    A novel approach that involved the grafting of diblock copolymer with two types of monomer onto substrate by sequential surface initiated-atom transfer radical polymerization was proposed to prepare a mixed-mode chromatographic stationary phase. The distinguishing feature of this method is that it can be applied in the preparation of various mixed-mode stationary phases. In this study, a new reverse-phase/ion-exchange stationary phase was prepared by grafting hydrophobic styrene and cationic sodium 4-styrenesulfonate by the proposed approach onto silica surface. The chromatographic properties of the prepared stationary phase were evaluated by the separation of benzene derivatives, anilines, and β-agonists, and by the effect of pH values and acetonitrile content on the retention. Compared with typical RP columns, the prepared stationary phase achieved the better resolution and higher selectivity at a shorter separation time and lower organic content. Moreover, the application of the prepared column was proved by separating widely distributed polar and charged compounds simultaneously. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. On a strong solution of the non-stationary Navier-Stokes equations under slip or leak boundary conditions of friction type

    NASA Astrophysics Data System (ADS)

    Kashiwabara, Takahito

    Strong solutions of the non-stationary Navier-Stokes equations under non-linearized slip or leak boundary conditions are investigated. We show that the problems are formulated by a variational inequality of parabolic type, to which uniqueness is established. Using Galerkin's method and deriving a priori estimates, we prove global and local existence for 2D and 3D slip problems respectively. For leak problems, under no-leak assumption at t=0 we prove local existence in 2D and 3D cases. Compatibility conditions for initial states play a significant role in the estimates.

  14. Metering Wheel-Wire Track Wire Boom Deployment Mechanism

    NASA Technical Reports Server (NTRS)

    Granoff, Mark S.

    2014-01-01

    The NASA MMS Spin Plane Double Probe (SDP) Deployer utilizes a helical path, rotating Metering Wheel and a spring loaded Wire "Holding" Track to pay out a "fixed end" 57 meter x 1.5 mm diameter Wire Boom stored between concentric storage cylinders. Unlike rotating spool type storage devices, the storage cylinders remain stationary, and the boom wire is uncoiled along the length of the cylinder via the rotation of the Metering Wheel. This uncoiling action avoids the need for slip-ring contacts since the ends of the wire can remain stationary. Conventional fixed electrical connectors (Micro-D type) are used to terminate to operational electronics.

  15. Air Emission Inventory for the Idaho National Engineering and Environmental Laboratory - Calendar Year 1999 Emission Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zohner, S.K.

    2000-05-30

    This report presents the 1999 calendar year update of the Air Emission Inventory for the Idaho National Engineering and Environmental Laboratory (INEEL). The INEEL Air Emission Inventory documents sources and emissions of nonradionuclide pollutants from operations at the INEEL. The report describes the emission inventory process and all of the sources at the INEEL, and provides nonradionuclide emissions estimates for stationary sources.

  16. Air Emission Inventory for the Idaho National Engineering and Environmental Laboratory - Calendar Year 1998 Emissions Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    S. K. Zohner

    1999-10-01

    This report presents the 1998 calendar year update of the Air Emission Inventory for the Idaho National Engineering and Environmental Laboratory (INEEL). The INEEL Air Emission Inventory documents sources and emissions of nonradionuclide pollutants from operations at the INEEL. The report describes the emission inventory process and all of the sources at the INEEL, and provides nonradiological emissions estimates for stationary sources.

  17. Two-dimensional quasineutral description of particles and fields above discrete auroral arcs

    NASA Technical Reports Server (NTRS)

    Newman, A. L.; Chiu, Y. T.; Cornwall, J. M.

    1985-01-01

    Stationary hot and cool particle distributions in the auroral magnetosphere are modelled using adiabatic assumptions of particle motion in the presence of broad-scale electrostatic potential structure. The study has identified geometrical restrictions on the type of broadscale potential structure which can be supported by a multispecies plasma having specified sources and energies. Without energization of cool thermal ionospheric electrons, a substantial parallel potential drop cannot be supported down to altitudes of 2000 km or less. Observed upward-directed field-aligned currents must be closed by return currents along field lines which support little net potential drop. In such regions the plasma density appears significantly enhanced. Model details agree well with recent broad-scale implications of satellite observations.

  18. Kinematics and the origin of the internal structures in HL Tauri jet (HH 151)

    NASA Astrophysics Data System (ADS)

    Movsessian, T. A.; Magakian, T. Yu.; Moiseev, A. V.

    2012-05-01

    Context. Knotty structures of Herbig-Haro jets are common phenomena, and knowing the origin of these structures is essential for understanding the processes of jet formation. Basically, there are two theoretical approaches: different types of instabilities in stationary flow, and velocity variations in the flow. Aims: We investigate the structures with different radial velocities in the knots of the HL Tau jet as well as its unusual behaviour starting from 20'' from the source. Collation of radial velocity data with proper motion measurements of emission structures in the jet of HL Tau makes it possible to understand the origin of these structures and decide on the mechanism for the formation of the knotty structures in Herbig-Haro flows. Methods: We present observations obtained with a 6 m telescope (Russia) using the SCORPIO camera with scanning Fabry-Perót interferometer. Two epochs of the observations of the HL/XZ Tau region in Hα emission (2001 and 2007) allowed us to measure proper motions for high and low radial velocity structures. Results: The structures with low and high radial velocities in the HL Tau jet show the same proper motion. The point where the HL Tau jet bents to the north (it coincides with the trailing edge of so-called knot A) is stationary, i.e. does not have any perceptible proper motion and is visible in Hα emission only. Conclusions: We conclude that the high- and low-velocity structures in the HL Tau jet represent bow-shocks and Mach disks in the internal working surfaces of episodic outflows. The bend of the jet and the brightness increase starting some distance from the source coincides with the observed stationary deflecting shock. The increase of relative surface brightness of bow-shocks could be the result of the abrupt change of the physical conditions of the ambient medium as well as the interaction of a highly collimated flow and the side wind from XZ Tau. Based on observations collected with the 6 m telescope of the Special Astrophysical Observatory (SAO) of the Russian Academy of Sciences (RAS), operated under the financial support of the Science Department of Russia (registration number 01-43).

  19. 40 CFR 60.342 - Standard for particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Lime... provisions of this subpart shall cause to be discharged into the atmosphere from any rotary lime kiln any...

  20. 40 CFR 60.2640 - When must the operator training course be completed?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emissions Guidelines and Compliance Times for Commercial and Industrial Solid Waste Incineration Units Model Rule-Operator...

  1. 40 CFR 60.2640 - When must the operator training course be completed?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emissions Guidelines and Compliance Times for Commercial and Industrial Solid Waste Incineration Units Model Rule-Operator...

  2. 40 CFR 60.70 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Nitric Acid Plants § 60.70 Applicability and designation of affected facility. (a) The provisions...

  3. 40 CFR 60.70 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Nitric Acid Plants § 60.70 Applicability and designation of affected facility. (a) The provisions...

  4. 40 CFR 60.175 - Monitoring of operations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Primary Zinc Smelters § 60.175 Monitoring of operations. (a) The owner or operator of any primary zinc smelter subject...

  5. 40 CFR 60.173 - Standard for sulfur dioxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Primary Zinc... percent of the sulfur initially contained in the zinc sulfide ore concentrates will be considered as a...

  6. 78 FR 51183 - Agency Information Collection Activities: Proposed Collection; Comment Request; Restructuring of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-20

    ... Collection Activities: Proposed Collection; Comment Request; Restructuring of the Stationary Source Audit... potentially affected by this action are those laboratories that supply audit samples. [[Page 51184

  7. 40 CFR 60.57a - [Reserved

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Municipal Waste Combustors for Which Construction is Commenced After December 20, 1989 and on or Before September 20, 1994 § 60.57a [Reserved] ...

  8. 40 CFR 60.57a - [Reserved

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Municipal Waste Combustors for Which Construction Is Commenced After December 20, 1989 and On or Before September 20, 1994 § 60.57a [Reserved] ...

  9. Distributed Water Pollution Source Localization with Mobile UV-Visible Spectrometer Probes in Wireless Sensor Networks.

    PubMed

    Ma, Junjie; Meng, Fansheng; Zhou, Yuexi; Wang, Yeyao; Shi, Ping

    2018-02-16

    Pollution accidents that occur in surface waters, especially in drinking water source areas, greatly threaten the urban water supply system. During water pollution source localization, there are complicated pollutant spreading conditions and pollutant concentrations vary in a wide range. This paper provides a scalable total solution, investigating a distributed localization method in wireless sensor networks equipped with mobile ultraviolet-visible (UV-visible) spectrometer probes. A wireless sensor network is defined for water quality monitoring, where unmanned surface vehicles and buoys serve as mobile and stationary nodes, respectively. Both types of nodes carry UV-visible spectrometer probes to acquire in-situ multiple water quality parameter measurements, in which a self-adaptive optical path mechanism is designed to flexibly adjust the measurement range. A novel distributed algorithm, called Dual-PSO, is proposed to search for the water pollution source, where one particle swarm optimization (PSO) procedure computes the water quality multi-parameter measurements on each node, utilizing UV-visible absorption spectra, and another one finds the global solution of the pollution source position, regarding mobile nodes as particles. Besides, this algorithm uses entropy to dynamically recognize the most sensitive parameter during searching. Experimental results demonstrate that online multi-parameter monitoring of a drinking water source area with a wide dynamic range is achieved by this wireless sensor network and water pollution sources are localized efficiently with low-cost mobile node paths.

  10. Distributed Water Pollution Source Localization with Mobile UV-Visible Spectrometer Probes in Wireless Sensor Networks

    PubMed Central

    Zhou, Yuexi; Wang, Yeyao; Shi, Ping

    2018-01-01

    Pollution accidents that occur in surface waters, especially in drinking water source areas, greatly threaten the urban water supply system. During water pollution source localization, there are complicated pollutant spreading conditions and pollutant concentrations vary in a wide range. This paper provides a scalable total solution, investigating a distributed localization method in wireless sensor networks equipped with mobile ultraviolet-visible (UV-visible) spectrometer probes. A wireless sensor network is defined for water quality monitoring, where unmanned surface vehicles and buoys serve as mobile and stationary nodes, respectively. Both types of nodes carry UV-visible spectrometer probes to acquire in-situ multiple water quality parameter measurements, in which a self-adaptive optical path mechanism is designed to flexibly adjust the measurement range. A novel distributed algorithm, called Dual-PSO, is proposed to search for the water pollution source, where one particle swarm optimization (PSO) procedure computes the water quality multi-parameter measurements on each node, utilizing UV-visible absorption spectra, and another one finds the global solution of the pollution source position, regarding mobile nodes as particles. Besides, this algorithm uses entropy to dynamically recognize the most sensitive parameter during searching. Experimental results demonstrate that online multi-parameter monitoring of a drinking water source area with a wide dynamic range is achieved by this wireless sensor network and water pollution sources are localized efficiently with low-cost mobile node paths. PMID:29462929

  11. Mobile acoustic transects miss rare bat species: implications of survey method and spatio-temporal sampling for monitoring bats

    PubMed Central

    Wallrichs, Megan A.; Ober, Holly K.; McCleery, Robert A.

    2017-01-01

    Due to increasing threats facing bats, long-term monitoring protocols are needed to inform conservation strategies. Effective monitoring should be easily repeatable while capturing spatio-temporal variation. Mobile acoustic driving transect surveys (‘mobile transects’) have been touted as a robust, cost-effective method to monitor bats; however, it is not clear how well mobile transects represent dynamic bat communities, especially when used as the sole survey approach. To assist biologists who must select a single survey method due to resource limitations, we assessed the effectiveness of three acoustic survey methods at detecting species richness in a vast protected area (Everglades National Park): (1) mobile transects, (2) stationary surveys that were strategically located by sources of open water and (3) stationary surveys that were replicated spatially across the landscape. We found that mobile transects underrepresented bat species richness compared to stationary surveys across all major vegetation communities and in two distinct seasons (dry/cool and wet/warm). Most critically, mobile transects failed to detect three rare bat species, one of which is federally endangered. Spatially replicated stationary surveys did not estimate higher species richness than strategically located stationary surveys, but increased the rate at which species were detected in one vegetation community. The survey strategy that detected maximum species richness and the highest mean nightly species richness with minimal effort was a strategically located stationary detector in each of two major vegetation communities during the wet/warm season. PMID:29134138

  12. Mobile acoustic transects miss rare bat species: implications of survey method and spatio-temporal sampling for monitoring bats.

    PubMed

    Braun de Torrez, Elizabeth C; Wallrichs, Megan A; Ober, Holly K; McCleery, Robert A

    2017-01-01

    Due to increasing threats facing bats, long-term monitoring protocols are needed to inform conservation strategies. Effective monitoring should be easily repeatable while capturing spatio-temporal variation. Mobile acoustic driving transect surveys ('mobile transects') have been touted as a robust, cost-effective method to monitor bats; however, it is not clear how well mobile transects represent dynamic bat communities, especially when used as the sole survey approach. To assist biologists who must select a single survey method due to resource limitations, we assessed the effectiveness of three acoustic survey methods at detecting species richness in a vast protected area (Everglades National Park): (1) mobile transects, (2) stationary surveys that were strategically located by sources of open water and (3) stationary surveys that were replicated spatially across the landscape. We found that mobile transects underrepresented bat species richness compared to stationary surveys across all major vegetation communities and in two distinct seasons (dry/cool and wet/warm). Most critically, mobile transects failed to detect three rare bat species, one of which is federally endangered. Spatially replicated stationary surveys did not estimate higher species richness than strategically located stationary surveys, but increased the rate at which species were detected in one vegetation community. The survey strategy that detected maximum species richness and the highest mean nightly species richness with minimal effort was a strategically located stationary detector in each of two major vegetation communities during the wet/warm season.

  13. Characterization of bonded stationary phase performance as a function of qualitative and quantitative chromatographic factors in chaotropic chromatography with risperidone and its impurities as model substances.

    PubMed

    Čolović, Jelena; Rmandić, Milena; Malenović, Anđelija

    2018-05-17

    Numerous stationary phases have been developed with the aim to provide desired performances during chromatographic analysis of the basic solutes in their protonated form. In this work, the procedure for the characterization of bonded stationary phase performance, when both qualitative and quantitative chromatographic factors were varied in chaotropic chromatography, was proposed. Risperidone and its three impurities were selected as model substances, while acetonitrile content in the mobile phase (20-30%), the pH of the aqueous phase (3.00-5.00), the content of chaotropic agents in the aqueous phase (10-100 mM), type of chaotropic agent (NaClO 4 , CF 3 COONa), and stationary phase type (Zorbax Eclipse XDB, Zorbax Extend) were studied as chromatographic factors. The proposed procedure implies the combination of D-optimal experimental design, indirect modeling, and polynomial-modified Gaussian model, while grid point search method was selected for the final choice of the experimental conditions which lead to the best possible stationary phase performance for basic solutes. Good agreement between experimentally obtained chromatogram and simulated chromatogram for chosen experimental conditions (25% acetonitrile, 75 mM of NaClO 4 , pH 4.00 on Zorbax Eclipse XDB column) confirmed the applicability of the proposed procedure. The additional point was selected for the verification of proposed procedure ability to distinguish changes in solutes' elution order. Simulated chromatogram for 21.5% acetonitrile, 85 mM of NaClO 4 , pH 5.00 on Zorbax Eclipse XDB column was in line with experimental data. Furthermore, the values of left and right peak half-widths obtained from indirect modeling were used in order to evaluate performances of differently modified stationary phases applying a half-width plots approach. The results from half-width plot approach as well as from the proposed procedure indicate higher efficiency and better separation performance of the stationary phase extra densely bonded and double end-capped with trimethylsilyl group than the stationary phase with the combination of end-capping and bidentate silane bonding for chromatographic analysis of basic solutes in RP-HPLC systems with chaotropic agents. Graphical abstract ᅟ.

  14. 77 FR 23178 - Approval and Promulgation of Air Quality Implementation Plans; Virginia; Deferral for CO2

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-18

    ... other than fossil fuels and mineral sources of carbon. Examples of ``biogenic CO 2 emissions'' include... biomass can be part of the national strategy to reduce dependence on fossil fuels. Efforts are underway at.... In that event, Virginia may revise its SIP accordingly. For stationary sources co-firing fossil fuel...

  15. 76 FR 79593 - Approval, and Promulgation of Air Quality Implementation Plans; Ohio; Redesignation of the Ohio...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-22

    ... sulfur dioxide (SO 2 ) emissions inventories as satisfying the requirement in section 172(c)(3) for a... and quantification of allowable emissions for major new and modified stationary sources in an area, and section 172(c)(5) requires source permits for the construction and operation of new and modified...

  16. 76 FR 18407 - Standards of Performance for New Stationary Sources and Emissions Guidelines for Existing Sources...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-04

    ... removing extraneous text from the hydrogen chloride emissions limit for large hospital/medical/infectious.../dibenzofurans, carbon monoxide, nitrogen oxides (NO X ), hydrogen chloride (HCl), and sulfur dioxide (SO 2...\\ dscf). Hydrogen chloride ppmv or percent 100 or 93% 100 or 93% 100 or 93% 3-run average (1- EPA...

  17. 40 CFR 60.1025 - Do subpart E new source performance standards also apply to my municipal waste combustion unit?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... standards also apply to my municipal waste combustion unit? 60.1025 Section 60.1025 Protection of... NEW STATIONARY SOURCES Standards of Performance for Small Municipal Waste Combustion Units for Which... municipal waste combustion unit? If this subpart AAAA applies to your municipal waste combustion unit, then...

  18. 40 CFR 60.1025 - Do subpart E new source performance standards also apply to my municipal waste combustion unit?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... standards also apply to my municipal waste combustion unit? 60.1025 Section 60.1025 Protection of... NEW STATIONARY SOURCES Standards of Performance for Small Municipal Waste Combustion Units for Which... municipal waste combustion unit? If this subpart AAAA applies to your municipal waste combustion unit, then...

  19. 40 CFR 60.1025 - Do subpart E new source performance standards also apply to my municipal waste combustion unit?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... standards also apply to my municipal waste combustion unit? 60.1025 Section 60.1025 Protection of... NEW STATIONARY SOURCES Standards of Performance for Small Municipal Waste Combustion Units for Which... municipal waste combustion unit? If this subpart AAAA applies to your municipal waste combustion unit, then...

  20. 40 CFR 60.1025 - Do subpart E new source performance standards also apply to my municipal waste combustion unit?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... standards also apply to my municipal waste combustion unit? 60.1025 Section 60.1025 Protection of... NEW STATIONARY SOURCES Standards of Performance for Small Municipal Waste Combustion Units for Which... municipal waste combustion unit? If this subpart AAAA applies to your municipal waste combustion unit, then...

Top